From abc969781888cf5425ed70b67fed57134acde136 Mon Sep 17 00:00:00 2001 From: Aadil Latif Date: Tue, 17 Jun 2025 07:31:51 -0600 Subject: [PATCH] gdm new version compliance --- docs/index.md | 2 +- docs/usage/mapping_phases.md | 4 ++-- docs/usage/mapping_voltages.md | 4 ++-- pyproject.toml | 4 ++-- src/shift/data_model.py | 10 ++++------ src/shift/mapper/base_voltage_mapper.py | 6 +++--- src/shift/mapper/edge_equipment_mapper.py | 16 ++++++++-------- src/shift/mapper/transformer_voltage_mapper.py | 8 ++++---- src/shift/system_builder.py | 6 +++--- src/shift/utils/split_network_edges.py | 11 +++-------- tests/models/p1rhs7_1247.json | 2 +- tests/models/p1rhs7_1247.json.bak | 2 +- tests/test_graph.py | 10 ++++------ 13 files changed, 38 insertions(+), 47 deletions(-) diff --git a/docs/index.md b/docs/index.md index 9ad0f7a..8a808a9 100644 --- a/docs/index.md +++ b/docs/index.md @@ -8,7 +8,7 @@ Primarily this package will leverage open street parcels, road network to build You can install this package from `main` branch using following command. ```bash -pip install "nrel-shift @ git+https://github.com/NREL-Distribution-Suites/shift.git@main" +pip install "nrel-shift" ``` ```{toctree} diff --git a/docs/usage/mapping_phases.md b/docs/usage/mapping_phases.md index 71cebb9..9129212 100644 --- a/docs/usage/mapping_phases.md +++ b/docs/usage/mapping_phases.md @@ -12,13 +12,13 @@ upon which equipment is used by equipment mapper. ```python from shift import TransformerPhaseMapperModel, TransformerTypes, BalancedPhaseMapper, add_phase_mapper_to_plot from gdm import DistributionTransformer -from gdm.quantities import PositiveApparentPower +from gdm.quantities import ApparentPower mapper = [ TransformerPhaseMapperModel( tr_name=el.name, tr_type=TransformerTypes.SPLIT_PHASE, - tr_capacity=PositiveApparentPower( + tr_capacity=ApparentPower( 25, "kilova", ), diff --git a/docs/usage/mapping_voltages.md b/docs/usage/mapping_voltages.md index b05ec49..333ba49 100644 --- a/docs/usage/mapping_voltages.md +++ b/docs/usage/mapping_voltages.md @@ -9,7 +9,7 @@ using transformer voltages. ```python from shift import TransformerVoltageMapper, TransformerVoltageModel, add_voltage_mapper_to_plot -from gdm.quantities import PositiveVoltage +from gdm.quantities import Voltage from gdm import DistributionTransformer voltage_mapper = TransformerVoltageMapper( @@ -17,7 +17,7 @@ voltage_mapper = TransformerVoltageMapper( xfmr_voltage=[ TransformerVoltageModel( name=el.name, - voltages=[PositiveVoltage(7.2, "kilovolt"), PositiveVoltage(120, "volt")], + voltages=[Voltage(7.2, "kilovolt"), Voltage(120, "volt")], ) for _, _, el in new_graph.get_edges() if el.edge_type is DistributionTransformer diff --git a/pyproject.toml b/pyproject.toml index 75e716b..00020b3 100644 --- a/pyproject.toml +++ b/pyproject.toml @@ -4,7 +4,7 @@ build-backend = "hatchling.build" [project] name = "nrel-shift" -version = "0.4.0" +version = "0.5.0" description = "Framework for developing synthetic distribution feeder model." readme = "README.md" requires-python = ">=3.10" @@ -25,7 +25,7 @@ dependencies = [ "scikit-learn", "plotly", "geopy", - "grid-data-models~=2.0.0", + "grid-data-models~=2.1.0", "importlib-metadata", ] diff --git a/src/shift/data_model.py b/src/shift/data_model.py index 3f1d81a..79b3d59 100644 --- a/src/shift/data_model.py +++ b/src/shift/data_model.py @@ -2,7 +2,7 @@ from enum import Enum from pydantic import BaseModel, Field, ConfigDict, model_validator -from gdm.quantities import PositiveVoltage, PositiveApparentPower, PositiveDistance +from gdm.quantities import Voltage, ApparentPower, Distance from gdm.distribution.components import ( DistributionLoad, DistributionSolar, @@ -60,9 +60,7 @@ class TransformerVoltageModel(BaseComponent): """Interface for transformer voltage model.""" name: Annotated[str, Field(..., description="Name of the transformer.")] - voltages: Annotated[ - list[PositiveVoltage], Field(..., description="List of transformer voltages.") - ] + voltages: Annotated[list[Voltage], Field(..., description="List of transformer voltages.")] class TransformerTypes(str, Enum): @@ -81,7 +79,7 @@ class TransformerPhaseMapperModel(BaseModel): model_config = ConfigDict(arbitrary_types_allowed=True) tr_name: str tr_type: TransformerTypes - tr_capacity: PositiveApparentPower + tr_capacity: ApparentPower location: Location @@ -116,7 +114,7 @@ class EdgeModel(BaseModel): model_config = ConfigDict(arbitrary_types_allowed=True) name: Annotated[str, Field(..., description="Name of the node.")] edge_type: Annotated[VALID_EDGE_TYPES, Field(..., description="Edge type.")] - length: Annotated[Optional[PositiveDistance], Field(None, description="Length of edge.")] + length: Annotated[Optional[Distance], Field(None, description="Length of edge.")] @model_validator(mode="after") def validate_fields(self): diff --git a/src/shift/mapper/base_voltage_mapper.py b/src/shift/mapper/base_voltage_mapper.py index 2c21e5e..43cf713 100644 --- a/src/shift/mapper/base_voltage_mapper.py +++ b/src/shift/mapper/base_voltage_mapper.py @@ -1,7 +1,7 @@ from abc import ABC, abstractmethod from functools import cached_property -from gdm.quantities import PositiveVoltage +from gdm.quantities import Voltage from shift.graph.distribution_graph import DistributionGraph @@ -24,10 +24,10 @@ def __init__(self, graph: DistributionGraph): @abstractmethod @cached_property - def node_voltage_mapping(self) -> dict[str, PositiveVoltage]: + def node_voltage_mapping(self) -> dict[str, Voltage]: """Returns dictionary mapping node name to line to ground voltage. Returns ------- - dict[str, tuple[PositiveVoltage, PositiveVoltage]] + dict[str, tuple[Voltage, Voltage]] """ diff --git a/src/shift/mapper/edge_equipment_mapper.py b/src/shift/mapper/edge_equipment_mapper.py index 1701bb6..c612d97 100644 --- a/src/shift/mapper/edge_equipment_mapper.py +++ b/src/shift/mapper/edge_equipment_mapper.py @@ -4,7 +4,7 @@ from infrasys.component import Component from gdm.dataset.dataset_system import DatasetSystem -from gdm.quantities import PositiveApparentPower, PositiveCurrent, PositiveVoltage +from gdm.quantities import ApparentPower, Current, Voltage from gdm.distribution.components import ( DistributionTransformer, DistributionBranchBase, @@ -58,10 +58,10 @@ def __init__( self.phase_mapper = phase_mapper super().__init__(graph) - def _get_load_power(self, load_equipment: LoadEquipment) -> PositiveApparentPower: + def _get_load_power(self, load_equipment: LoadEquipment) -> ApparentPower: """Internal method to return total load power.""" - return PositiveApparentPower( + return ApparentPower( sum( [ math.sqrt( @@ -76,7 +76,7 @@ def _get_load_power(self, load_equipment: LoadEquipment) -> PositiveApparentPowe "kilova", ) - def _get_served_load(self, from_node: str, to_node: str) -> PositiveApparentPower: + def _get_served_load(self, from_node: str, to_node: str) -> ApparentPower: """Internal method to get load served downward from this edge.""" dfs_graph = self.graph.get_dfs_tree() parent_node = from_node if dfs_graph.has_edge(from_node, to_node) else to_node @@ -88,7 +88,7 @@ def _get_served_load(self, from_node: str, to_node: str) -> PositiveApparentPowe and DistributionLoad in x.assets ) ) - served_load = PositiveApparentPower(0, "kilova") + served_load = ApparentPower(0, "kilova") for node in load_nodes: equipment = self.node_asset_equipment_mapping[node.name][DistributionLoad] if not isinstance(equipment, LoadEquipment): @@ -98,7 +98,7 @@ def _get_served_load(self, from_node: str, to_node: str) -> PositiveApparentPowe return served_load def _get_closest_transformer_equipment( - self, capacity: PositiveApparentPower, num_phase: int, voltages: list[PositiveVoltage] + self, capacity: ApparentPower, num_phase: int, voltages: list[Voltage] ) -> Component: """Internal method to return transformer equipment by capacity.""" @@ -131,7 +131,7 @@ def filter_func(x: DistributionTransformerEquipment): return sorted(trs, key=lambda x: x.windings[0].rated_power)[0] def _get_closest_branch_equipment( - self, type_: Type[Component], current: PositiveCurrent, num_phase: int + self, type_: Type[Component], current: Current, num_phase: int ) -> Component: """Internal method to return closest conductor equipment.""" if issubclass(type_, MatrixImpedanceBranchEquipment): @@ -197,7 +197,7 @@ def edge_equipment_mapping(self) -> dict[str, Component]: edge_equipment_mapper[edge.name] = self._get_closest_branch_equipment( EQUIPMENT_TO_CLASS_TYPE[edge.edge_type], - PositiveCurrent(current, "ampere"), + Current(current, "ampere"), num_phase, ) return edge_equipment_mapper diff --git a/src/shift/mapper/transformer_voltage_mapper.py b/src/shift/mapper/transformer_voltage_mapper.py index cc10b58..63b79bd 100644 --- a/src/shift/mapper/transformer_voltage_mapper.py +++ b/src/shift/mapper/transformer_voltage_mapper.py @@ -1,7 +1,7 @@ from functools import cached_property from typing import Callable -from gdm.quantities import PositiveVoltage +from gdm.quantities import Voltage from gdm.distribution.components import DistributionTransformer import networkx as nx @@ -49,7 +49,7 @@ def _update_mapper_by_func( self, nodes: list[str], xfmr: TransformerVoltageModel, - mapper: dict[str, PositiveVoltage], + mapper: dict[str, Voltage], compare_func: Callable, ): """Internal function to update voltage mapper.""" @@ -60,8 +60,8 @@ def _update_mapper_by_func( mapper[node] = compare_func(xfmr.voltages) @cached_property - def node_voltage_mapping(self) -> dict[str, PositiveVoltage]: - node_voltages: dict[str, PositiveVoltage] = {} + def node_voltage_mapping(self) -> dict[str, Voltage]: + node_voltages: dict[str, Voltage] = {} dfs_tree = self.graph.get_dfs_tree() xfmrs_in_mapper = [xfmr.name for xfmr in self.xfmr_voltage] edges = self.graph.get_edges(filter_func=lambda x: x.name in xfmrs_in_mapper) diff --git a/src/shift/system_builder.py b/src/shift/system_builder.py index f5f5a35..7188716 100644 --- a/src/shift/system_builder.py +++ b/src/shift/system_builder.py @@ -14,7 +14,7 @@ VoltageTypes, Phase, ) -from gdm.quantities import PositiveVoltage +from gdm.quantities import Voltage import numpy as np from shift.data_model import ( @@ -126,9 +126,9 @@ def _add_branch(self, from_node: str, to_node: str, edge_data: EdgeModel): self._system.add_component(edge) @staticmethod - def _get_wdg_voltages(tr_equipment: DistributionTransformerEquipment) -> PositiveVoltage: + def _get_wdg_voltages(tr_equipment: DistributionTransformerEquipment) -> Voltage: """Internal method to return winding phase voltages.""" - return PositiveVoltage( + return Voltage( [ wdg.rated_voltage.to("kilovolt").magnitude / ( diff --git a/src/shift/utils/split_network_edges.py b/src/shift/utils/split_network_edges.py index 91dafec..abb7fb2 100644 --- a/src/shift/utils/split_network_edges.py +++ b/src/shift/utils/split_network_edges.py @@ -5,14 +5,11 @@ from geopy.distance import geodesic import numpy as np from infrasys.quantities import Distance -from gdm.quantities import PositiveDistance from shift.data_model import GeoLocation -def get_distance_between_points( - from_point: GeoLocation, to_point: GeoLocation -) -> PositiveDistance: +def get_distance_between_points(from_point: GeoLocation, to_point: GeoLocation) -> Distance: """Returns distance betwee two geo points. Parameters @@ -25,12 +22,10 @@ def get_distance_between_points( Returns ------- - PositiveDistance + Distance """ - return PositiveDistance( - geodesic(*[reversed(point) for point in [from_point, to_point]]).m, "m" - ) + return Distance(geodesic(*[reversed(point) for point in [from_point, to_point]]).m, "m") def split_network_edges(graph: nx.Graph, split_length: Distance) -> nx.Graph: diff --git a/tests/models/p1rhs7_1247.json b/tests/models/p1rhs7_1247.json index 2af1b78..a7a7f05 100644 --- a/tests/models/p1rhs7_1247.json +++ b/tests/models/p1rhs7_1247.json @@ -1 +1 @@ -{"name": null, "description": null, "uuid": "46939f3b-e363-402b-96d5-075fea00bb3c", "data_format_version": "1.4.4", "components": [{"uuid": "b3ec0470-4645-4817-8d9e-36a62dd25e7b", "name": "", "limit_type": "min", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "base"}}, "value": {"value": 37.84531014537997, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}}, {"uuid": "6f2e6cad-94d8-43ba-82be-43800c8ff5c3", "name": "", "limit_type": "max", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "base"}}, "value": {"value": 41.82902700278839, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}}, {"uuid": "198717db-85ba-42fb-bb64-8404694680f4", "name": "", "x": 38.64060097099336, "y": -122.50688851789585, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "574ab810-c1b0-4662-8c4d-f32ab6893a36", "name": "p1rhs7_69", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "b3ec0470-4645-4817-8d9e-36a62dd25e7b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "6f2e6cad-94d8-43ba-82be-43800c8ff5c3"}}}], "nominal_voltage": {"value": 39.83716857408418, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "198717db-85ba-42fb-bb64-8404694680f4"}}}}, {"uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e", "name": "", "limit_type": "min", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "base"}}, "value": {"value": 6.839579963954902, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}}, {"uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4", "name": "", "limit_type": "max", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "base"}}, "value": {"value": 7.559535749634366, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}}, {"uuid": "43cd04c2-460c-452d-86bf-a5589f142291", "name": "", "x": 38.64000605387684, "y": -122.50715315149552, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "30052484-94f2-43a3-abb7-9314d4593c20", "name": "sb10_p1rhs7_1247_bus_10_6", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "43cd04c2-460c-452d-86bf-a5589f142291"}}}}, {"uuid": "03718c17-c4ff-4e1c-8455-8fcf4a4af180", "name": "", "x": 38.63991059999376, "y": -122.50713209215856, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ed5e3889-e8c8-4215-adb8-9880f8937da5", "name": "p1rdt6488-p1rhs7_1247x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "03718c17-c4ff-4e1c-8455-8fcf4a4af180"}}}}, {"uuid": "0488d677-5c3a-4447-9757-a609b80ee957", "name": "", "x": 38.64000458987126, "y": -122.50680575213045, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "23779a0d-9859-4591-b4ce-7ec704401d42", "name": "sb10_p1rhs7_1247_bus_10_7", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0488d677-5c3a-4447-9757-a609b80ee957"}}}}, {"uuid": "55ae0586-0c23-44a5-9795-611001c2b35b", "name": "", "x": 38.63990849507586, "y": -122.50663270624317, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1548dd91-bc3d-4a2c-903f-48e11159c558", "name": "p1rdt7711-p1rhs7_1247x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "55ae0586-0c23-44a5-9795-611001c2b35b"}}}}, {"uuid": "fef667d2-e160-4e42-93ec-3fe9b5fa8815", "name": "", "x": 38.64015019482659, "y": -122.50741272190496, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f4d9a6e8-eb1b-454c-ae94-2eb435218fb9", "name": "sb10_p1rhs7_1247_bus_10_4", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fef667d2-e160-4e42-93ec-3fe9b5fa8815"}}}}, {"uuid": "2b867617-7e8c-4db9-ade6-b774fb29b86d", "name": "", "x": 38.64000705978231, "y": -122.50739198857364, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "14208aa5-3197-4c90-adf9-3067dae9b5f9", "name": "p1rdt5342-p1rhs7_1247x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2b867617-7e8c-4db9-ade6-b774fb29b86d"}}}}, {"uuid": "d32bc420-6934-4d7e-91ab-1e3398b02d2c", "name": "", "x": 38.640146717948795, "y": -122.5065876467693, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2427b8de-af1a-44f8-9774-724e635057fb", "name": "sb10_p1rhs7_1247_bus_10_5", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d32bc420-6934-4d7e-91ab-1e3398b02d2c"}}}}, {"uuid": "e9c98454-f906-4403-becb-00deac9c5c8c", "name": "", "x": 38.64000266679855, "y": -122.50634979050211, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ec7726f8-0afb-4c35-8a1b-0691a8fb400d", "name": "p1rdt8583-p1rhs7_1247x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e9c98454-f906-4403-becb-00deac9c5c8c"}}}}, {"uuid": "08b140ca-c960-474e-ac23-6e6580d6298c", "name": "", "x": 38.640398325892065, "y": -122.5068899064944, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "001adbd4-6616-4dce-83d2-025e896ada51", "name": "sb10_p1rhs7_1247_node_10_7", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "08b140ca-c960-474e-ac23-6e6580d6298c"}}}}, {"uuid": "0783a135-88c7-4b30-86a9-f2f6557c594a", "name": "", "x": 38.64033927342312, "y": -122.50702059026854, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3856ea8d-83da-4d2e-8f66-fae6c69b5db1", "name": "sb10_p1rhs7_1247_bus_10_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0783a135-88c7-4b30-86a9-f2f6557c594a"}}}}, {"uuid": "07d60bfb-ce5e-4d51-9638-eb8860046b02", "name": "", "x": 38.64024290434973, "y": -122.50678240569646, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c975b603-30a6-4ed1-bbae-696d1c5b0a3d", "name": "sb10_p1rhs7_1247_bus_10_3", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "07d60bfb-ce5e-4d51-9638-eb8860046b02"}}}}, {"uuid": "7fd62588-3463-4a61-8c5d-1bb88b8c086a", "name": "", "x": 38.640245008643895, "y": -122.50728179394365, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6263cae0-e97a-4044-a130-e971a626d3c1", "name": "sb10_p1rhs7_1247_bus_10_2", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7fd62588-3463-4a61-8c5d-1bb88b8c086a"}}}}, {"uuid": "09d479e2-73cb-4c6e-9182-419e2c7d9217", "name": "", "x": 38.64044600709302, "y": -122.50688957976658, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16bb904e-b153-4b0a-97f5-53ad7c6606d8", "name": "sb10_p1rhs7_1247_node_10_6", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "b3ec0470-4645-4817-8d9e-36a62dd25e7b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "6f2e6cad-94d8-43ba-82be-43800c8ff5c3"}}}], "nominal_voltage": {"value": 39.83716857408418, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "09d479e2-73cb-4c6e-9182-419e2c7d9217"}}}}, {"uuid": "154210fc-9811-4963-880a-2605cc049534", "name": "", "x": 38.64052944919371, "y": -122.50688900799106, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ca7962b4-686c-4bee-af8d-f1851b835adb", "name": "sb10_p1rhs7_1247_node_10_5", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "b3ec0470-4645-4817-8d9e-36a62dd25e7b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "6f2e6cad-94d8-43ba-82be-43800c8ff5c3"}}}], "nominal_voltage": {"value": 39.83716857408418, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "154210fc-9811-4963-880a-2605cc049534"}}}}, {"uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc", "name": "", "limit_type": "min", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "base"}}, "value": {"value": 0.11408441319187004, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}}, {"uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5", "name": "", "limit_type": "max", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "base"}}, "value": {"value": 0.12609329879101427, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}}, {"uuid": "c9b5dc22-6b6c-4e4f-bb66-434e7a4937bf", "name": "", "x": 38.58930068802498, "y": -122.47407241728135, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3541a1a-9680-4baf-9b87-a1322cb1a16a", "name": "p1rdt4964lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c9b5dc22-6b6c-4e4f-bb66-434e7a4937bf"}}}}, {"uuid": "cececd48-9462-4a04-90f8-afe07e75e821", "name": "", "x": 38.58928688389361, "y": -122.47412342379597, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "02e86824-b793-4080-9401-c6995a365baf", "name": "p1rlv10170", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cececd48-9462-4a04-90f8-afe07e75e821"}}}}, {"uuid": "b99a2ad7-5611-486b-890e-ec585d6cdc15", "name": "", "x": 38.58730261534203, "y": -122.47493972983303, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ab731358-e17f-4c48-b6f8-c7bb4c7701de", "name": "p1rdt4980lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b99a2ad7-5611-486b-890e-ec585d6cdc15"}}}}, {"uuid": "88aed81c-9aee-49c7-b399-6d35c3018dbd", "name": "", "x": 38.586999682758396, "y": -122.47455116112062, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "58f2b2c3-4f6f-4fd2-abb9-42ff665692bd", "name": "p1rlv10189", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "88aed81c-9aee-49c7-b399-6d35c3018dbd"}}}}, {"uuid": "d25f087f-69b4-4209-ac90-8818cc55484e", "name": "", "x": 38.5874921997227, "y": -122.47522897778698, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6b4caeee-6304-4a25-a7d8-44c6014b5e37", "name": "p1rlv10574", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d25f087f-69b4-4209-ac90-8818cc55484e"}}}}, {"uuid": "d4aaf336-5d7e-46b9-9bb6-f7d1ed0c4e09", "name": "", "x": 38.587371992400946, "y": -122.47517995477224, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aad9ea92-9403-4ac0-9aaf-7e845b8c7bb5", "name": "p1rlv10596", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d4aaf336-5d7e-46b9-9bb6-f7d1ed0c4e09"}}}}, {"uuid": "5b862a31-20f0-4f36-926e-88ecbddd6658", "name": "", "x": 38.58881837779083, "y": -122.47343065419352, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0375d197-ccd2-4ed8-9439-857b700cefb8", "name": "p1rdt5017lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5b862a31-20f0-4f36-926e-88ecbddd6658"}}}}, {"uuid": "609e696a-a153-4e81-a0de-294f1949fda2", "name": "", "x": 38.58885966670059, "y": -122.47344264204159, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3317d7c2-2588-426d-91fc-3d765b932da6", "name": "p1rlv10262", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "609e696a-a153-4e81-a0de-294f1949fda2"}}}}, {"uuid": "8925aa98-b97a-4609-928a-4c2fb1511718", "name": "", "x": 38.62911239194669, "y": -122.48794713837246, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7e33e473-8d5b-4704-bdab-56032991f94e", "name": "p1rdt5126lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8925aa98-b97a-4609-928a-4c2fb1511718"}}}}, {"uuid": "83e7ddaa-1339-44f6-924d-5a5f6a3cf8cf", "name": "", "x": 38.6290864193847, "y": -122.48790451626458, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8f7116b9-96c1-42c8-850f-7787f5fd0f96", "name": "p1rlv10491", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "83e7ddaa-1339-44f6-924d-5a5f6a3cf8cf"}}}}, {"uuid": "84da10da-2cca-45f7-9864-c2b1098caa40", "name": "", "x": 38.625434851806375, "y": -122.44516017839125, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dd4b469b-001b-4914-8e51-e98fe3f6babb", "name": "p1rdm10619", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "84da10da-2cca-45f7-9864-c2b1098caa40"}}}}, {"uuid": "791f4ebc-b1a0-4617-b265-6f27b679cd92", "name": "", "x": 38.625158815750815, "y": -122.44586307086524, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "31f26b28-fc9d-4b3d-b204-cf40f3478c44", "name": "p1rlv10521", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "791f4ebc-b1a0-4617-b265-6f27b679cd92"}}}}, {"uuid": "905821af-0745-45f1-9947-ecdae59a1230", "name": "", "x": 38.625299188790116, "y": -122.44505783200565, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e28a5f3a-4447-469a-85dd-e232d8c6d728", "name": "p1rdm10620", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "905821af-0745-45f1-9947-ecdae59a1230"}}}}, {"uuid": "fc3d809d-3c65-4bcc-8227-0daa8d5f70f7", "name": "", "x": 38.62519279357018, "y": -122.44542626681253, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "73ada6ad-ace7-46c1-80f7-2cb33cf4cdb3", "name": "p1rlv10641", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fc3d809d-3c65-4bcc-8227-0daa8d5f70f7"}}}}, {"uuid": "fe8f593f-9830-4c8d-8ac2-c631589cabcb", "name": "", "x": 38.625591389135096, "y": -122.44526633659068, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5f114a56-98d7-4fe8-b0b1-b8c4bc791cf9", "name": "p1rdt5140lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fe8f593f-9830-4c8d-8ac2-c631589cabcb"}}}}, {"uuid": "c0c3cf78-7bf0-4327-987d-79699acfeb78", "name": "", "x": 38.62571524353723, "y": -122.44537629052095, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e09d217e-44a5-4013-8d48-8546d6bb1dc3", "name": "p1rdm10621", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c0c3cf78-7bf0-4327-987d-79699acfeb78"}}}}, {"uuid": "b087818c-f0c4-44e8-86b3-a358f5f73403", "name": "", "x": 38.62565276187416, "y": -122.44550314021144, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "07f95ba5-92dd-465f-a38d-8e878243262b", "name": "p1rlv20071", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b087818c-f0c4-44e8-86b3-a358f5f73403"}}}}, {"uuid": "8efabcfe-13b9-41a1-adeb-db0ab55a0905", "name": "", "x": 38.622332296573816, "y": -122.44976008456518, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e071635-4071-470d-be09-4484cb90441a", "name": "p1rdt5142lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8efabcfe-13b9-41a1-adeb-db0ab55a0905"}}}}, {"uuid": "fe5c7977-cf01-48d0-8145-1e49d6d26df0", "name": "", "x": 38.62217684357621, "y": -122.44988366265912, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35d47036-a044-4c67-b5b5-0006e2a3b68e", "name": "p1rlv10523", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fe5c7977-cf01-48d0-8145-1e49d6d26df0"}}}}, {"uuid": "919ab874-ec10-4b43-841d-de5560c6f8ce", "name": "", "x": 38.62245506643117, "y": -122.44964029908394, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a5717e0-080e-46ae-918a-64fe4fcba5d7", "name": "p1rlv10616", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "919ab874-ec10-4b43-841d-de5560c6f8ce"}}}}, {"uuid": "2108dc95-1071-454c-a014-d592b62560ac", "name": "", "x": 38.58825755415666, "y": -122.46710557327793, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ec20ad2-b04f-43fc-ad8d-d41746549a57", "name": "p1rdt5153lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2108dc95-1071-454c-a014-d592b62560ac"}}}}, {"uuid": "8ae7ce00-9a27-47f2-9b8b-068f0cd24e76", "name": "", "x": 38.58776776322457, "y": -122.46703633124763, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a302271d-4cf3-45ff-9308-b9cf31fbefa3", "name": "p1rlv10538", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8ae7ce00-9a27-47f2-9b8b-068f0cd24e76"}}}}, {"uuid": "cae2d3e5-816f-4b6b-958a-6c6d061dfe81", "name": "", "x": 38.58793840849323, "y": -122.4669087674479, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cfbe5665-c020-455a-addc-d3f9514735ed", "name": "p1rlv10586", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cae2d3e5-816f-4b6b-958a-6c6d061dfe81"}}}}, {"uuid": "b2f0ad91-48b4-488d-b58e-a9a570478b91", "name": "", "x": 38.58801998355576, "y": -122.46701150268488, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b91354e-ce50-44d0-a959-fa451bb9cf20", "name": "p1rlv10610", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b2f0ad91-48b4-488d-b58e-a9a570478b91"}}}}, {"uuid": "daf9b693-80a3-42ee-8706-c161353b3bee", "name": "", "x": 38.62299459252021, "y": -122.44285578875113, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "85351f49-cb19-4f71-a6ae-a21f5a48af6f", "name": "p1rdt5155lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "daf9b693-80a3-42ee-8706-c161353b3bee"}}}}, {"uuid": "7717760f-23fb-40cd-a9b0-f0188f35b9f2", "name": "", "x": 38.62296860365152, "y": -122.44281318670158, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4829cd2f-7e61-4386-89ce-89d77d5ef5cf", "name": "p1rlv10540", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7717760f-23fb-40cd-a9b0-f0188f35b9f2"}}}}, {"uuid": "9413b231-e7d1-4a46-adac-dcb6f32db7d4", "name": "", "x": 38.623416278049106, "y": -122.44435741173649, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ba7e3a6b-f62f-432f-afe7-2ebbfc9abd59", "name": "p1rdt5159lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9413b231-e7d1-4a46-adac-dcb6f32db7d4"}}}}, {"uuid": "1c49be6d-fc4c-418f-9b44-644a6e2a42e2", "name": "", "x": 38.62339028972311, "y": -122.44431480889065, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6c722b89-fdaf-416f-863e-02b443375ba1", "name": "p1rlv10544", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1c49be6d-fc4c-418f-9b44-644a6e2a42e2"}}}}, {"uuid": "57af24fc-2f2e-4145-b371-ee77999bac6c", "name": "", "x": 38.62398776024399, "y": -122.44276641347568, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48efdcb9-083c-4e17-a1d2-acb1388f085e", "name": "p1rdt5172lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "57af24fc-2f2e-4145-b371-ee77999bac6c"}}}}, {"uuid": "1d70710d-9a07-4242-a38f-5d47bc190b51", "name": "", "x": 38.62338766087452, "y": -122.44294734474045, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c8a10822-398f-441e-a5ca-73303d832183", "name": "p1rlv10563", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d70710d-9a07-4242-a38f-5d47bc190b51"}}}}, {"uuid": "eb9ecf04-f209-4a45-9ca6-f9115d073e72", "name": "", "x": 38.618803618131444, "y": -122.45181229136102, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dd4155b2-ca55-41d7-bd35-98a5eec8c39a", "name": "p1rdt5179lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eb9ecf04-f209-4a45-9ca6-f9115d073e72"}}}}, {"uuid": "ef045117-9d8f-4b4a-a616-40bcd5391aa5", "name": "", "x": 38.61925559252727, "y": -122.4515026734116, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "94677ede-fd5c-4fbb-bfcd-98cf67b56913", "name": "p1rlv10573", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef045117-9d8f-4b4a-a616-40bcd5391aa5"}}}}, {"uuid": "fd077f51-6fff-413f-bf0e-4488154496fc", "name": "", "x": 38.61839344506758, "y": -122.45214101800151, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a0431d17-75da-48c1-965c-875f61b0e9bf", "name": "p1rlv10583", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fd077f51-6fff-413f-bf0e-4488154496fc"}}}}, {"uuid": "be95eaa2-f600-4067-97f2-e6070d375414", "name": "", "x": 38.62221649276758, "y": -122.44627684656544, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ae26acb3-c2c9-479c-9d19-c30bf00aa8c5", "name": "p1rdt5180lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be95eaa2-f600-4067-97f2-e6070d375414"}}}}, {"uuid": "be1285dd-72ff-4444-817f-574f0346a2c9", "name": "", "x": 38.622228136819786, "y": -122.44632961498499, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25141e20-0a65-4905-b37f-954ed1a8751c", "name": "p1rlv10576", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be1285dd-72ff-4444-817f-574f0346a2c9"}}}}, {"uuid": "10c2c882-6746-444f-b809-677b728156cf", "name": "", "x": 38.58486127149263, "y": -122.47507613100927, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3bbde2e8-42c0-486b-9759-78898d177f93", "name": "p1rdt5183lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10c2c882-6746-444f-b809-677b728156cf"}}}}, {"uuid": "560205af-2471-40f9-8e3e-65f51ade10de", "name": "", "x": 38.584860090382186, "y": -122.47502224179047, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cdfa726f-5606-4ae2-b358-ad664dd7b0e3", "name": "p1rlv10582", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "560205af-2471-40f9-8e3e-65f51ade10de"}}}}, {"uuid": "3337f64c-470e-47ce-a97e-4d4570af0515", "name": "", "x": 38.6246895952918, "y": -122.44633371298471, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1656cc28-8a5b-40da-887f-25605dd336aa", "name": "p1rdt5184lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3337f64c-470e-47ce-a97e-4d4570af0515"}}}}, {"uuid": "6bd43a1d-48a8-4497-b3e4-8d0ec3aab2bc", "name": "", "x": 38.624682565233414, "y": -122.4461539331612, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "53019a8a-b453-4add-9d2d-e4ab380fce67", "name": "p1rlv10589", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6bd43a1d-48a8-4497-b3e4-8d0ec3aab2bc"}}}}, {"uuid": "ddc1bf24-6112-491d-b9b2-c3ffeaac64de", "name": "", "x": 38.624602168391775, "y": -122.44630389385829, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "feb19590-c5f4-4982-9e99-20599f08cfe7", "name": "p1rlv10600", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ddc1bf24-6112-491d-b9b2-c3ffeaac64de"}}}}, {"uuid": "41225cc6-cdcb-463a-a44f-1fbec5c8f0f3", "name": "", "x": 38.62484662068028, "y": -122.44654326007226, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "374d5417-b2c4-4d16-9b91-d2f519921fd8", "name": "p1rlv10621", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "41225cc6-cdcb-463a-a44f-1fbec5c8f0f3"}}}}, {"uuid": "463f4f85-69a4-45bc-87ec-d0f8a40b0c82", "name": "", "x": 38.649308955445846, "y": -122.40285111885804, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf05c1bb-39cc-48b3-a576-18913e0cff13", "name": "p1rdt5195lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "463f4f85-69a4-45bc-87ec-d0f8a40b0c82"}}}}, {"uuid": "4935e47a-85c4-40c5-83a4-8c706d58814d", "name": "", "x": 38.649342089627496, "y": -122.40283537845332, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1b175fcb-d1ee-44eb-8f89-826e40c5db1d", "name": "p1rlv10615", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4935e47a-85c4-40c5-83a4-8c706d58814d"}}}}, {"uuid": "4d8947e5-f3a0-43f2-bb3c-c156b337ea40", "name": "", "x": 38.64914651543566, "y": -122.40280650016945, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3184f056-3b5f-403d-86a0-f9b28d6bb3e3", "name": "p1rlv10634", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d8947e5-f3a0-43f2-bb3c-c156b337ea40"}}}}, {"uuid": "26aa33e2-1edf-424f-b548-410cbaee9b20", "name": "", "x": 38.58803256102546, "y": -122.4709126113251, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "03e7bfdb-ff8b-4142-95ef-8d848ff5d2db", "name": "p1rdt5200lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "26aa33e2-1edf-424f-b548-410cbaee9b20"}}}}, {"uuid": "eedd822e-ac93-4283-b769-4a115d88068e", "name": "", "x": 38.58800658229211, "y": -122.47087001955629, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32406d7d-51f9-4c16-900b-526985e5f62b", "name": "p1rlv10627", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eedd822e-ac93-4283-b769-4a115d88068e"}}}}, {"uuid": "5e69e0e7-a169-409b-aa08-29275566fae9", "name": "", "x": 38.62310262007371, "y": -122.44472743619623, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b8162a8c-5339-4f42-bd7a-b6dbc5ff463b", "name": "p1rdt5201lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5e69e0e7-a169-409b-aa08-29275566fae9"}}}}, {"uuid": "8a684d6a-e879-403d-b98a-145e2c82abb8", "name": "", "x": 38.623076631881446, "y": -122.44468483339944, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e183b3e8-d995-4f1e-baee-8d9d4add157e", "name": "p1rlv10629", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8a684d6a-e879-403d-b98a-145e2c82abb8"}}}}, {"uuid": "009b7291-1ad4-4e31-812f-20a22582b7f8", "name": "", "x": 38.647579222155, "y": -122.40883933742933, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "39eaedd7-75b6-449f-8ff6-6e31f6e74504", "name": "p1rdt5202lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "009b7291-1ad4-4e31-812f-20a22582b7f8"}}}}, {"uuid": "737a5433-f6cd-4820-bed5-b01766e07a38", "name": "", "x": 38.64738178775039, "y": -122.40899959560872, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8d60a935-dc9b-48ea-8ee7-9b682452035e", "name": "p1rlv10630", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "737a5433-f6cd-4820-bed5-b01766e07a38"}}}}, {"uuid": "a1331dcf-bb83-4354-a0d1-9adaf14bd4a2", "name": "", "x": 38.645656291690415, "y": -122.4075034535507, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "599a2995-33d5-4bcc-8cd3-585ea37577cd", "name": "p1rdt5206lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a1331dcf-bb83-4354-a0d1-9adaf14bd4a2"}}}}, {"uuid": "76105b9d-ef6e-4669-aa1a-d7354b4c1846", "name": "", "x": 38.64561400003638, "y": -122.40750498256921, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e9510bd0-2bba-4522-bfbe-20b94ea400b6", "name": "p1rlv10637", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "76105b9d-ef6e-4669-aa1a-d7354b4c1846"}}}}, {"uuid": "3b3ae9e8-ee45-4b39-a9d2-b653896ffc6e", "name": "", "x": 38.65641154150713, "y": -122.39587823120766, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c650eda9-132b-4419-a055-ad68037c7772", "name": "p1rdt5218lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3b3ae9e8-ee45-4b39-a9d2-b653896ffc6e"}}}}, {"uuid": "f8592191-94d2-423d-a9cc-66bf4448c219", "name": "", "x": 38.656425923289945, "y": -122.39592902455765, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8198c1c5-67e0-49b9-b11a-1f266f7f4bcb", "name": "p1rlv10663", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f8592191-94d2-423d-a9cc-66bf4448c219"}}}}, {"uuid": "cc50144a-f184-4913-a41b-8e0739907a56", "name": "", "x": 38.641472751242716, "y": -122.48093037801921, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5f252d81-66ee-40a6-bce7-2891e06b39e4", "name": "p1rdt5236lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc50144a-f184-4913-a41b-8e0739907a56"}}}}, {"uuid": "6a6587af-c013-4f7f-a20c-cca2a39b8c90", "name": "", "x": 38.64148709617754, "y": -122.48098117829157, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d3d48c0e-704d-4205-94a2-ee74be7ae350", "name": "p1rlv10720", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a6587af-c013-4f7f-a20c-cca2a39b8c90"}}}}, {"uuid": "69d6c981-12fa-4fb6-b646-c5cc5e4d9eaf", "name": "", "x": 38.641937121819915, "y": -122.50369495559332, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e01069aa-388b-4362-9d02-a164f173dc20", "name": "p1rdt5342lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "69d6c981-12fa-4fb6-b646-c5cc5e4d9eaf"}}}}, {"uuid": "dc80310e-0c48-4dc4-ba11-988bd5a787f0", "name": "", "x": 38.64182806242219, "y": -122.50347514079304, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75dbf8f0-4cb6-49b7-a2a5-f98e9ff4b8df", "name": "p1rlv10955", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dc80310e-0c48-4dc4-ba11-988bd5a787f0"}}}}, {"uuid": "f9149994-925b-428c-8a33-66b8460df8e8", "name": "", "x": 38.642018719214704, "y": -122.50380705470455, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0a8fc823-6fe8-4a3b-9437-68aa751f5e3b", "name": "p1rlv11048", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f9149994-925b-428c-8a33-66b8460df8e8"}}}}, {"uuid": "86ec09c9-13eb-44cd-a1b1-3711d57cfccb", "name": "", "x": 38.642205431006985, "y": -122.4576909223735, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "34a1276e-c702-4c69-b7b1-566d400da2de", "name": "p1rdt5472lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "86ec09c9-13eb-44cd-a1b1-3711d57cfccb"}}}}, {"uuid": "c8226150-c622-4980-9f33-95cb9cf66220", "name": "", "x": 38.64217944750302, "y": -122.4576483036143, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f949a06a-817e-4666-95bb-9536ce06a694", "name": "p1rlv11380", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c8226150-c622-4980-9f33-95cb9cf66220"}}}}, {"uuid": "d51b82c8-7885-4679-b8ed-12a631d090e7", "name": "", "x": 38.63960343978653, "y": -122.45649923239668, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5d181674-9355-488b-8a3f-5b7c844c35a5", "name": "p1rdt5475lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d51b82c8-7885-4679-b8ed-12a631d090e7"}}}}, {"uuid": "c119fba5-939c-479d-8bec-f034962dca28", "name": "", "x": 38.63981590397471, "y": -122.45628682931535, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e0c23aea-471f-4d10-9500-1bc14a67d7e7", "name": "p1rlv11384", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c119fba5-939c-479d-8bec-f034962dca28"}}}}, {"uuid": "f9b337b1-5557-4cd2-90b5-fe2127096eaf", "name": "", "x": 38.63963394395313, "y": -122.45652552675769, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7f512d86-c9d9-4f58-9d5a-418d0732dc94", "name": "p1rlv11386", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f9b337b1-5557-4cd2-90b5-fe2127096eaf"}}}}, {"uuid": "ee00163c-6526-4f99-80db-96be6a310440", "name": "", "x": 38.63927702838603, "y": -122.4566815679821, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9fd316b0-fd98-4193-9c1b-aaa7d92a4284", "name": "p1rlv11397", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ee00163c-6526-4f99-80db-96be6a310440"}}}}, {"uuid": "68f4463f-0f9f-4317-a2f9-fbe04b0afa9d", "name": "", "x": 38.639428183564455, "y": -122.46174457730311, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0888f4c5-e037-4891-99fb-fd43934ffae0", "name": "p1rdt5476lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "68f4463f-0f9f-4317-a2f9-fbe04b0afa9d"}}}}, {"uuid": "49097a9b-5c02-4d19-9fce-192f24b100ec", "name": "", "x": 38.639434265073014, "y": -122.46179953026234, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2115e8bb-fe49-49ad-8687-68feca212557", "name": "p1rlv11385", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "49097a9b-5c02-4d19-9fce-192f24b100ec"}}}}, {"uuid": "9f133821-96eb-4579-aee6-925be1a09527", "name": "", "x": 38.642101120835456, "y": -122.45608173877747, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fafd64c3-efe5-4684-b06f-44e4c8555aa4", "name": "p1rdt5477lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9f133821-96eb-4579-aee6-925be1a09527"}}}}, {"uuid": "1cf42564-0cee-4e41-85fc-b6e4694082f9", "name": "", "x": 38.64166518451146, "y": -122.45668651807028, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cbca8c57-0da4-4368-9821-7a9ca4282173", "name": "p1rlv11387", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1cf42564-0cee-4e41-85fc-b6e4694082f9"}}}}, {"uuid": "c753ea66-6b44-4f63-9692-64bd0a9737e0", "name": "", "x": 38.63719096576592, "y": -122.45830192704182, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5107bc9c-f463-49f6-a92f-23c5730475e2", "name": "p1rdt5478lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c753ea66-6b44-4f63-9692-64bd0a9737e0"}}}}, {"uuid": "6e9acac3-2384-45c3-b797-5bcce4603394", "name": "", "x": 38.63771659092773, "y": -122.4583249236366, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "12377bf0-f258-4c29-ab26-e938c95ee25c", "name": "p1rlv11388", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6e9acac3-2384-45c3-b797-5bcce4603394"}}}}, {"uuid": "38e78d90-477b-4736-9dde-04ab72558727", "name": "", "x": 38.63670708849592, "y": -122.4582865622578, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "97aa01fe-2e60-4617-8c89-d36f425087fe", "name": "p1rlv11398", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "38e78d90-477b-4736-9dde-04ab72558727"}}}}, {"uuid": "4f990b5f-70ec-4d45-b79a-ee56910b1e0d", "name": "", "x": 38.64171847326658, "y": -122.45537480795159, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "004f56b2-ec94-4189-91b8-46b4af22faa6", "name": "p1rdm11569", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4f990b5f-70ec-4d45-b79a-ee56910b1e0d"}}}}, {"uuid": "b46ddb8c-258a-46e0-9cc5-ce3594b0f2a0", "name": "", "x": 38.64245774536079, "y": -122.45464667599991, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9b6420b1-3456-42fc-9266-c2b84e063cec", "name": "p1rlv11390", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b46ddb8c-258a-46e0-9cc5-ce3594b0f2a0"}}}}, {"uuid": "94a3ded1-2e9b-42c2-9115-27ab1198f1ad", "name": "", "x": 38.641798080115834, "y": -122.45558638857214, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "44ac9e38-8ae3-4102-822b-1c638a6c878a", "name": "p1rdt5480lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "94a3ded1-2e9b-42c2-9115-27ab1198f1ad"}}}}, {"uuid": "9c167415-a423-4f44-bf0d-2c02116b5458", "name": "", "x": 38.64189515756268, "y": -122.45575404043835, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8be902f6-4cca-4ce5-9f73-a1f96c65d8ef", "name": "p1rdm11570", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9c167415-a423-4f44-bf0d-2c02116b5458"}}}}, {"uuid": "b944b2db-b9e5-412c-9cf9-8b7a3f920690", "name": "", "x": 38.64223524158617, "y": -122.45524587802178, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a215d7dd-8081-4355-9c38-4fd3d2c859c7", "name": "p1rlv11401", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b944b2db-b9e5-412c-9cf9-8b7a3f920690"}}}}, {"uuid": "1b663de6-20e1-48d3-b3c9-6f141c4a5ca7", "name": "", "x": 38.64020129527885, "y": -122.45644080950349, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f213ee9e-6ae7-4e82-9f25-6fc456f45576", "name": "p1rdt5481lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1b663de6-20e1-48d3-b3c9-6f141c4a5ca7"}}}}, {"uuid": "eab215e8-2ae0-46fd-a218-fd08beaa74e3", "name": "", "x": 38.64014090557112, "y": -122.45641076765583, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e740a352-ac8f-4ae2-ace3-254fccd7f96f", "name": "p1rlv11392", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eab215e8-2ae0-46fd-a218-fd08beaa74e3"}}}}, {"uuid": "22a6c911-8788-4f98-b55b-a8a2368bf128", "name": "", "x": 38.640303433007105, "y": -122.45647848222762, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "996d3e44-142c-42fa-bf4f-2bd1777122dd", "name": "p1rlv11394", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "22a6c911-8788-4f98-b55b-a8a2368bf128"}}}}, {"uuid": "7db0ae48-3ebd-433d-9568-05f0c398309d", "name": "", "x": 38.64168447824798, "y": -122.45542011758508, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8a73d544-9f33-49d9-b648-c806addf3c06", "name": "p1rdt5483lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7db0ae48-3ebd-433d-9568-05f0c398309d"}}}}, {"uuid": "81ff1e3e-2885-4592-9965-5945d231f979", "name": "", "x": 38.64195529639681, "y": -122.45512160027936, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "29922f55-f36a-4b9e-8836-5f9dadd641b7", "name": "p1rlv11395", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "81ff1e3e-2885-4592-9965-5945d231f979"}}}}, {"uuid": "288eb15e-e98b-4fdb-824b-6b63988c8235", "name": "", "x": 38.6393583769313, "y": -122.45589692178642, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "40eaefce-482f-4a89-bec1-2c11bac2bfb7", "name": "p1rdt5485lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "288eb15e-e98b-4fdb-824b-6b63988c8235"}}}}, {"uuid": "9a233f64-0a3f-4005-ac29-8df3dc67c147", "name": "", "x": 38.63937273269481, "y": -122.45594771545282, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "68a9eead-8197-4e82-a444-2a4544ec9ddb", "name": "p1rlv11399", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9a233f64-0a3f-4005-ac29-8df3dc67c147"}}}}, {"uuid": "67bfd210-882e-4eb2-b12d-7335778f6e07", "name": "", "x": 38.57143813832739, "y": -122.49015904841082, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "28a6e44b-c6c7-4556-b4d8-d55359391c66", "name": "p1rdt5650lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "67bfd210-882e-4eb2-b12d-7335778f6e07"}}}}, {"uuid": "e6ad383e-e706-44b6-8583-c21c9e8f308d", "name": "", "x": 38.57142432703484, "y": -122.49021003925405, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "834a5733-5264-4adf-861a-25e494df3e37", "name": "p1rlv11671", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e6ad383e-e706-44b6-8583-c21c9e8f308d"}}}}, {"uuid": "3aaeb5f6-c3be-4c8d-ac2c-284fc845d759", "name": "", "x": 38.65464557723489, "y": -122.39724791960451, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "38d1de19-1f51-4875-acc2-a75e3d1a290e", "name": "p1rdt5653lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3aaeb5f6-c3be-4c8d-ac2c-284fc845d759"}}}}, {"uuid": "196dcfb1-cbe1-481a-b575-c37dc4ed0da8", "name": "", "x": 38.65508992916787, "y": -122.39723667691878, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "45f2a901-e4f7-4055-a3e2-b60c61d5033e", "name": "p1rlv11674", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "196dcfb1-cbe1-481a-b575-c37dc4ed0da8"}}}}, {"uuid": "63fded38-9e61-45e7-8ae6-58ed56c3a1c9", "name": "", "x": 38.57263362388283, "y": -122.495683769354, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "87e8c57e-67ff-439c-b28b-0fbdbfd62ea6", "name": "p1rdt5656lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "63fded38-9e61-45e7-8ae6-58ed56c3a1c9"}}}}, {"uuid": "59d4774b-339b-4dc2-9d3d-807731c082ae", "name": "", "x": 38.5726198101849, "y": -122.49573476001369, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8b2f121a-2202-43c0-8684-81913a5d6ea9", "name": "p1rlv11677", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59d4774b-339b-4dc2-9d3d-807731c082ae"}}}}, {"uuid": "c8f6dffd-c572-4d99-b2a4-19421d74334c", "name": "", "x": 38.57280585377797, "y": -122.4929323788313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ea73a91a-b052-486e-810b-1a5ad281e07b", "name": "p1rdt5662lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c8f6dffd-c572-4d99-b2a4-19421d74334c"}}}}, {"uuid": "d4bd3e1e-9577-4201-9f8e-450e5cb4257e", "name": "", "x": 38.57242796617633, "y": -122.49307054728973, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "02aef971-5f4a-4ca8-aa33-cce34517bd44", "name": "p1rlv11684", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d4bd3e1e-9577-4201-9f8e-450e5cb4257e"}}}}, {"uuid": "1c8ccecf-94f0-4086-9894-43ca68c27898", "name": "", "x": 38.56680617078412, "y": -122.49719640898832, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16a67a88-5d11-4eca-85fe-38c948ad362c", "name": "p1rdt5663lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1c8ccecf-94f0-4086-9894-43ca68c27898"}}}}, {"uuid": "da50b7f4-c1bf-47df-ab82-73a5722737b9", "name": "", "x": 38.5668199513191, "y": -122.49730717896358, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cda8e361-98b6-49bd-a3ff-30a036a3dc6f", "name": "p1rlv11686", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "da50b7f4-c1bf-47df-ab82-73a5722737b9"}}}}, {"uuid": "b4ec8b1c-107b-490d-9bb4-eb8aa4f0a2a2", "name": "", "x": 38.56665994983674, "y": -122.49716304017915, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e5b71ca5-a7ab-42f7-824a-bc43fc1708cc", "name": "p1rdm11909", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b4ec8b1c-107b-490d-9bb4-eb8aa4f0a2a2"}}}}, {"uuid": "23b77dd8-f10c-4624-953a-3e440aa570f4", "name": "", "x": 38.566580963860986, "y": -122.49765717235252, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "449098c3-4f65-4350-863f-4b7bc1f14493", "name": "p1rlv15645", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "23b77dd8-f10c-4624-953a-3e440aa570f4"}}}}, {"uuid": "1ba63c10-373f-4350-b961-c90fd652abb4", "name": "", "x": 38.5707010215685, "y": -122.51444963387745, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6d456893-4d89-455a-b1a5-4863aad6293a", "name": "p1rdt5728lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1ba63c10-373f-4350-b961-c90fd652abb4"}}}}, {"uuid": "1f21215a-9d08-4812-8efd-536b0eded845", "name": "", "x": 38.57009391258443, "y": -122.51433495859402, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f0ba1408-17da-4678-8b04-90c616c3fb48", "name": "p1rlv11779", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1f21215a-9d08-4812-8efd-536b0eded845"}}}}, {"uuid": "d07cefa0-6a4a-4ea1-833c-1f8c7239b2ec", "name": "", "x": 38.57127534957151, "y": -122.51454511366566, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3890375-c01d-44d2-93f9-8d9d60da8852", "name": "p1rlv11783", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d07cefa0-6a4a-4ea1-833c-1f8c7239b2ec"}}}}, {"uuid": "65b9e11a-d035-49fe-9c2f-a18adc520bfa", "name": "", "x": 38.56955818331602, "y": -122.51459989092113, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "95f81d7a-a6af-4843-bfa1-002abc7ff870", "name": "p1rdt5729lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65b9e11a-d035-49fe-9c2f-a18adc520bfa"}}}}, {"uuid": "03cf9cc3-74d3-41be-ac9e-4c958be1448f", "name": "", "x": 38.56953222036641, "y": -122.51455729408103, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6e9a574d-9537-417a-a811-e22d84b8ea53", "name": "p1rlv11780", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "03cf9cc3-74d3-41be-ac9e-4c958be1448f"}}}}, {"uuid": "0a193e3d-f76a-4d4c-a33b-8d6eb8250e44", "name": "", "x": 38.57213402094206, "y": -122.51802514483155, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2dd206bc-965d-46c9-8fdb-8c158c7bba05", "name": "p1rdt5730lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a193e3d-f76a-4d4c-a33b-8d6eb8250e44"}}}}, {"uuid": "0198df5e-1335-4d36-b7fa-ea83c51eda03", "name": "", "x": 38.57199490295793, "y": -122.51856958078595, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b66df0bc-6159-42fa-bf49-b8ad17d0e6aa", "name": "p1rlv11784", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0198df5e-1335-4d36-b7fa-ea83c51eda03"}}}}, {"uuid": "1dd4f217-6d64-4bf3-be52-b765773001a9", "name": "", "x": 38.572056756934636, "y": -122.51827070037027, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b15fc66-89d9-483b-9c9f-9b0f39a63b29", "name": "p1rlv11786", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1dd4f217-6d64-4bf3-be52-b765773001a9"}}}}, {"uuid": "3142c953-b8bb-4934-aa7e-9394d697aafe", "name": "", "x": 38.572019292356316, "y": -122.51792656501027, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "64ee7f4c-b91a-4a25-b85d-a91b83777c1f", "name": "p1rdm12071", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3142c953-b8bb-4934-aa7e-9394d697aafe"}}}}, {"uuid": "ea02cc30-f701-4e2e-af04-30113338ce57", "name": "", "x": 38.571920919935685, "y": -122.51811089442202, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "28fd9f7c-0195-4529-a972-aa60eced47d2", "name": "p1rlv11781", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea02cc30-f701-4e2e-af04-30113338ce57"}}}}, {"uuid": "bb99e5fd-69c7-462b-8027-3c89a73aaa07", "name": "", "x": 38.56688129837257, "y": -122.51477378591451, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6e414162-eda7-4cf2-9116-fc24af9461bf", "name": "p1rdt5731lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bb99e5fd-69c7-462b-8027-3c89a73aaa07"}}}}, {"uuid": "a7bd841c-64ad-46a9-9b40-c7c407b24606", "name": "", "x": 38.5669221751359, "y": -122.51444813822336, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "496fc854-bbf8-463b-b16c-12dd1b444cc6", "name": "p1rlv11782", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a7bd841c-64ad-46a9-9b40-c7c407b24606"}}}}, {"uuid": "9b3e1b1d-5f5a-4ed6-bba2-f666acf4a2f6", "name": "", "x": 38.56702296960097, "y": -122.51484921518147, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7103c2f0-8160-434f-b4b3-edfbd7e97464", "name": "p1rdm12075", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9b3e1b1d-5f5a-4ed6-bba2-f666acf4a2f6"}}}}, {"uuid": "72915b72-842d-4d23-8777-a66df68ae209", "name": "", "x": 38.5670581599183, "y": -122.51464236147093, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ed0eb774-fcc3-417f-a8a4-fbdb825cc106", "name": "p1rlv11785", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "72915b72-842d-4d23-8777-a66df68ae209"}}}}, {"uuid": "ac2ebf07-87cc-46ac-affc-3aad7a0927ef", "name": "", "x": 38.57345429314894, "y": -122.51994138004522, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9974869d-7d87-4a27-9606-076cd7799953", "name": "p1rdt5840lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ac2ebf07-87cc-46ac-affc-3aad7a0927ef"}}}}, {"uuid": "dc36d120-77b5-4b62-95f8-a90964499200", "name": "", "x": 38.57328942198139, "y": -122.51998442674298, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1dfd848-b639-41b5-ad95-2c03a51bd36b", "name": "p1rlv12028", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dc36d120-77b5-4b62-95f8-a90964499200"}}}}, {"uuid": "0c5bf3c3-b2bf-4b42-95ef-eb2a0f8846dd", "name": "", "x": 38.573586478514756, "y": -122.51990209164686, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fc4d79bb-8ba3-4146-9d50-16db48ffec22", "name": "p1rlv12157", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0c5bf3c3-b2bf-4b42-95ef-eb2a0f8846dd"}}}}, {"uuid": "b2724222-42d6-4b39-9bdc-a131b20c18d3", "name": "", "x": 38.61540289404265, "y": -122.4340916885271, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "751d2f2e-bb6f-4ca6-9e86-0e2b5ff3f92a", "name": "p1rdt5923lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b2724222-42d6-4b39-9bdc-a131b20c18d3"}}}}, {"uuid": "f3ca5954-1325-4b71-ab86-ab13dee31042", "name": "", "x": 38.615385277507826, "y": -122.43359039737986, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "df9d9de2-6929-48a4-a390-c0e2f129b374", "name": "p1rlv12214", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f3ca5954-1325-4b71-ab86-ab13dee31042"}}}}, {"uuid": "00db6112-34c3-46a6-abeb-4f179fbbd1a9", "name": "", "x": 38.615361354746774, "y": -122.43423382325552, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c4d26673-c304-41de-8b5b-149552601ba4", "name": "p1rlv12217", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "00db6112-34c3-46a6-abeb-4f179fbbd1a9"}}}}, {"uuid": "63fba15d-7056-4866-a483-76cfd4b7b3d1", "name": "", "x": 38.61582271842178, "y": -122.43459776600604, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cee79fe8-f140-4be9-aa6b-d56e37fb6857", "name": "p1rlv12222", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "63fba15d-7056-4866-a483-76cfd4b7b3d1"}}}}, {"uuid": "ef651d7a-fc6b-426f-b064-fc2e60a74988", "name": "", "x": 38.61514654148174, "y": -122.43395232342587, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e8e1f797-9417-447c-8a08-cf00a462ef14", "name": "p1rlv12225", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef651d7a-fc6b-426f-b064-fc2e60a74988"}}}}, {"uuid": "7c88c271-f3f6-45d4-9919-0e24699d4215", "name": "", "x": 38.586418831345604, "y": -122.50394128809963, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d654945d-b71d-4943-86a2-5830fca200c9", "name": "p1rdt6038lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7c88c271-f3f6-45d4-9919-0e24699d4215"}}}}, {"uuid": "ab853430-e034-4565-b98b-2589bd82df86", "name": "", "x": 38.58644635289331, "y": -122.50405591684549, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b42c2471-9114-4042-980e-dd226ad024a3", "name": "p1rlv12538", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ab853430-e034-4565-b98b-2589bd82df86"}}}}, {"uuid": "3d46fae0-0a33-4fd5-ac7e-6282cd5526e1", "name": "", "x": 38.583699762043224, "y": -122.50722384389097, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e5ae7bbf-f53e-4ae2-8145-bf56ce935094", "name": "p1rdt6043lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3d46fae0-0a33-4fd5-ac7e-6282cd5526e1"}}}}, {"uuid": "8037a8ee-3906-490a-9533-13016db8fd6c", "name": "", "x": 38.583590695705574, "y": -122.50712562826531, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4c42d772-e2a8-45d4-9cf2-2edd7a567b35", "name": "p1rlv12552", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8037a8ee-3906-490a-9533-13016db8fd6c"}}}}, {"uuid": "2aa9b7fa-506a-4f8c-8242-7ecbcfa25a2d", "name": "", "x": 38.58378667878022, "y": -122.50658466351123, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b3e53a11-6c13-4d27-89f2-2abbd28f69ac", "name": "p1rdm12875", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2aa9b7fa-506a-4f8c-8242-7ecbcfa25a2d"}}}}, {"uuid": "65da88d8-f338-4c87-9275-83b61c7bfc38", "name": "", "x": 38.58345266624825, "y": -122.50644917302039, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a29aec49-62a4-41ec-a67c-a84470a23f7b", "name": "p1rlv12553", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65da88d8-f338-4c87-9275-83b61c7bfc38"}}}}, {"uuid": "ea0e1728-da0c-415a-b2d8-63292335ef42", "name": "", "x": 38.58361036220623, "y": -122.50751586004849, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b748c697-b624-43f0-b375-5024d8cff92b", "name": "p1rdm12876", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea0e1728-da0c-415a-b2d8-63292335ef42"}}}}, {"uuid": "279d7791-7332-446f-84ff-965c7c9af534", "name": "", "x": 38.58369185365201, "y": -122.50760715446228, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75a47101-b6df-473e-9c7b-96e076c17931", "name": "p1rlv12559", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "279d7791-7332-446f-84ff-965c7c9af534"}}}}, {"uuid": "533b497d-f2b9-4c9a-b5d2-76e4e9c93a3c", "name": "", "x": 38.58357450876428, "y": -122.50756203032971, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3082eb6b-1a9f-4b6e-930e-f58173fe02ac", "name": "p1rdm12877", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "533b497d-f2b9-4c9a-b5d2-76e4e9c93a3c"}}}}, {"uuid": "efefb47a-9073-4b89-a2b8-7be8b197bb61", "name": "", "x": 38.58361995350426, "y": -122.5076535708703, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8b0417d3-820d-4daa-aec5-3dcf34e40e00", "name": "p1rlv12562", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "efefb47a-9073-4b89-a2b8-7be8b197bb61"}}}}, {"uuid": "6989f2f9-0ff1-40bd-a0b5-15527010b9ad", "name": "", "x": 38.583744918789954, "y": -122.50735404765867, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b2e2d1a7-039c-4b29-a061-b814ac675e3b", "name": "p1rdt6046lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6989f2f9-0ff1-40bd-a0b5-15527010b9ad"}}}}, {"uuid": "efcefbeb-719b-4ce3-b9ad-5d962103723a", "name": "", "x": 38.5839884657107, "y": -122.50742142633933, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4fe4d6ae-cca5-476c-981a-a1dcd27b1e84", "name": "p1rlv12557", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "efcefbeb-719b-4ce3-b9ad-5d962103723a"}}}}, {"uuid": "313e68dc-5043-4c00-aeb7-0a6788fddbe1", "name": "", "x": 38.5843554229652, "y": -122.50614844559887, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "21e75ccd-7e21-4f0d-890c-81aa6b33b109", "name": "p1rdt6047lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "313e68dc-5043-4c00-aeb7-0a6788fddbe1"}}}}, {"uuid": "a3824258-2643-48e3-8a13-8ebabaac90ac", "name": "", "x": 38.584325151037234, "y": -122.50605283115296, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0a427f20-861a-4616-9443-265beaeccca3", "name": "p1rlv12558", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a3824258-2643-48e3-8a13-8ebabaac90ac"}}}}, {"uuid": "1b8d5c33-b1ec-42d0-a6da-c5736badbefd", "name": "", "x": 38.605026243337974, "y": -122.47603639568145, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "01be483b-09f4-450e-a39d-78692c40ee8b", "name": "p1rdt6208lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1b8d5c33-b1ec-42d0-a6da-c5736badbefd"}}}}, {"uuid": "39d40bfc-7bc0-40d3-8121-d070af0c9f8b", "name": "", "x": 38.60501243846355, "y": -122.47608741299466, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "019e419c-9f88-455a-bf48-b89531ed9e51", "name": "p1rlv12936", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "39d40bfc-7bc0-40d3-8121-d070af0c9f8b"}}}}, {"uuid": "384d4ef5-af8c-43a0-a01a-b48e88a27593", "name": "", "x": 38.60004659977005, "y": -122.48124037604637, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "73f78740-2ec5-4ad8-b7fb-40f4a72b730e", "name": "p1rdt6221lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "384d4ef5-af8c-43a0-a01a-b48e88a27593"}}}}, {"uuid": "e8e66f12-8da3-41bd-b6fa-3dcac2ae471f", "name": "", "x": 38.60002062477275, "y": -122.48119777346218, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8418804f-aad5-49df-9916-f427da5089c1", "name": "p1rlv12959", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e8e66f12-8da3-41bd-b6fa-3dcac2ae471f"}}}}, {"uuid": "5aef84c3-b54b-424d-8ebe-45dc09d4dd79", "name": "", "x": 38.604436381862065, "y": -122.47563389239149, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3154eee7-a1ba-4b9d-9e91-bab55529d358", "name": "p1rdt6226lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5aef84c3-b54b-424d-8ebe-45dc09d4dd79"}}}}, {"uuid": "a4d56043-79b9-4411-b7b6-c7e551d90dfa", "name": "", "x": 38.604742034520584, "y": -122.47609857017211, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be845651-8e1c-4b6d-8633-fcbdfb1fd5d4", "name": "p1rlv12971", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a4d56043-79b9-4411-b7b6-c7e551d90dfa"}}}}, {"uuid": "2b9957d6-67cd-47ad-8f4b-d0ec588d795e", "name": "", "x": 38.60407996866283, "y": -122.47516164611108, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "646058a3-cda7-4723-bd0f-05d305fe7c11", "name": "p1rlv20185", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2b9957d6-67cd-47ad-8f4b-d0ec588d795e"}}}}, {"uuid": "459fe982-19fb-4fc7-937f-3429aa535d9f", "name": "", "x": 38.61627084774632, "y": -122.45497361088964, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "72ce0706-6b32-4b4b-9bf3-fd1f5a6af5ca", "name": "p1rdt6268lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "459fe982-19fb-4fc7-937f-3429aa535d9f"}}}}, {"uuid": "9667d696-5ea7-451e-9dd5-318e13202abf", "name": "", "x": 38.616595375163186, "y": -122.45499188425644, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3072c6c-3a40-4e49-bd00-febc8268b135", "name": "p1rlv13043", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9667d696-5ea7-451e-9dd5-318e13202abf"}}}}, {"uuid": "5b18d64b-c7b4-4e7f-b793-a467aa5f1eb0", "name": "", "x": 38.61557658935668, "y": -122.45489621541526, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4209bdad-276f-4e07-93e0-78b162ce95cf", "name": "p1rlv13047", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5b18d64b-c7b4-4e7f-b793-a467aa5f1eb0"}}}}, {"uuid": "f0178992-d931-4425-b1f8-6cf772629d45", "name": "", "x": 38.61659769116569, "y": -122.45488097254983, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "21c6ea4f-ec9d-424e-8743-7175408f9e2c", "name": "p1rlv13054", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f0178992-d931-4425-b1f8-6cf772629d45"}}}}, {"uuid": "cb47612f-823d-4fd9-b8da-f9f951b87220", "name": "", "x": 38.615484628332915, "y": -122.45948878298002, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "79c91fa8-15ad-4e8d-96bd-2cad395dd280", "name": "p1rdt6269lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb47612f-823d-4fd9-b8da-f9f951b87220"}}}}, {"uuid": "5f7b1184-1a50-4c3b-abc1-6f10d6b0e56b", "name": "", "x": 38.61545864547562, "y": -122.45944617926628, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fa31c772-8460-4624-a123-64b87ca8d332", "name": "p1rlv13044", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5f7b1184-1a50-4c3b-abc1-6f10d6b0e56b"}}}}, {"uuid": "e5f6f0cd-c468-47f3-8889-ba4631b16481", "name": "", "x": 38.61293890712679, "y": -122.45937135963467, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5adb2083-3d46-48a7-8996-37c0781b0215", "name": "p1rdt6270lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e5f6f0cd-c468-47f3-8889-ba4631b16481"}}}}, {"uuid": "d0437a27-08ad-41e0-a4a5-0be10eada9ba", "name": "", "x": 38.61312062731428, "y": -122.45970448051091, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6070414d-09e7-48a7-aec0-c105cc0f1a93", "name": "p1rlv13045", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d0437a27-08ad-41e0-a4a5-0be10eada9ba"}}}}, {"uuid": "a6648dc2-4180-476b-84b9-d71723671f17", "name": "", "x": 38.61305606107207, "y": -122.459383355912, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5edc15fb-49d5-4052-8fad-4979578f6ed1", "name": "p1rlv13046", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a6648dc2-4180-476b-84b9-d71723671f17"}}}}, {"uuid": "6e31ef12-0466-48cc-9ff0-19a2da1c50f8", "name": "", "x": 38.612568269488285, "y": -122.45913432583363, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "86d59550-d7c8-47e1-a6bc-14b2d50de58c", "name": "p1rlv13052", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6e31ef12-0466-48cc-9ff0-19a2da1c50f8"}}}}, {"uuid": "a27adeee-5e06-4c0b-935d-a908465d154f", "name": "", "x": 38.61201252826336, "y": -122.45742705644044, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1335e64c-9f37-4e73-a37f-8f76737cabff", "name": "p1rdt6271lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a27adeee-5e06-4c0b-935d-a908465d154f"}}}}, {"uuid": "e19ce3da-55ab-4c6b-ad4c-5f038c6b2ffb", "name": "", "x": 38.6124662872462, "y": -122.45657372759852, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "569078be-37c2-4c05-8455-91945eb7fdb9", "name": "p1rlv13048", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e19ce3da-55ab-4c6b-ad4c-5f038c6b2ffb"}}}}, {"uuid": "f6a8b3a9-1c2a-45e7-a53b-b1002f1822ad", "name": "", "x": 38.61056246852402, "y": -122.45546646876214, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "04422e0a-1952-422d-a201-5fafef1875db", "name": "p1rdt6272lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f6a8b3a9-1c2a-45e7-a53b-b1002f1822ad"}}}}, {"uuid": "d0a8d9b3-58c2-4f85-9b1b-a839988d3996", "name": "", "x": 38.61046043697304, "y": -122.45545178295872, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3ed85192-4c5a-4c15-ba21-1ba883b03ddd", "name": "p1rlv13049", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d0a8d9b3-58c2-4f85-9b1b-a839988d3996"}}}}, {"uuid": "170ec7fe-fcf7-4acf-b429-559cbeaf6976", "name": "", "x": 38.61065269092905, "y": -122.4554887580758, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e058437-0138-4305-a33e-d8fa61aed8cc", "name": "p1rlv13053", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "170ec7fe-fcf7-4acf-b429-559cbeaf6976"}}}}, {"uuid": "bc8f8b98-5280-45f9-8ac4-52ad1f005535", "name": "", "x": 38.61008611720184, "y": -122.45635048585197, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2b6739c0-1b15-42c1-9fdd-4d7f604a03ce", "name": "p1rdm13376", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bc8f8b98-5280-45f9-8ac4-52ad1f005535"}}}}, {"uuid": "68405c44-dbe2-4a6b-9268-accf72aead68", "name": "", "x": 38.61016439157834, "y": -122.45574115998643, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e9a855b0-538e-4fab-91f1-93b4ece09409", "name": "p1rlv13051", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "68405c44-dbe2-4a6b-9268-accf72aead68"}}}}, {"uuid": "e2efd60d-46ec-4832-9b23-6f31a690ecb5", "name": "", "x": 38.61026024108263, "y": -122.45636462882881, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b1db8c80-e791-4c31-a6f2-713aa665bf41", "name": "p1rdt6274lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e2efd60d-46ec-4832-9b23-6f31a690ecb5"}}}}, {"uuid": "cbd8342d-f215-4a5b-9bb6-d8f6f08670f7", "name": "", "x": 38.610392670089375, "y": -122.45638262926296, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e395985-4c66-49c9-9252-94d8078b8e8e", "name": "p1rdm13377", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cbd8342d-f215-4a5b-9bb6-d8f6f08670f7"}}}}, {"uuid": "4e8da740-8364-40d4-81e3-115c6cd3df80", "name": "", "x": 38.610432528075556, "y": -122.45587299013495, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16584dfd-537d-4b0d-a651-c73d0beabc6d", "name": "p1rlv13056", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4e8da740-8364-40d4-81e3-115c6cd3df80"}}}}, {"uuid": "fbf44c78-ce05-4b63-960e-76194f6ae49f", "name": "", "x": 38.610983387394924, "y": -122.45878265444647, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ba567584-fbee-44eb-b3f1-da24a0ce66a0", "name": "p1rdt6275lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fbf44c78-ce05-4b63-960e-76194f6ae49f"}}}}, {"uuid": "5111021a-6b72-40f1-b986-267d9c612a93", "name": "", "x": 38.61089111139205, "y": -122.45892869017909, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "387df3d3-5f03-47f4-8b16-bea8815e63d1", "name": "p1rlv13055", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5111021a-6b72-40f1-b986-267d9c612a93"}}}}, {"uuid": "b1bffdbe-f800-471c-a218-2352f3de7841", "name": "", "x": 38.611024903573316, "y": -122.45862905688004, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c83997dc-872f-494f-8c8a-7266c854fc48", "name": "p1rlv13058", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b1bffdbe-f800-471c-a218-2352f3de7841"}}}}, {"uuid": "8daf5a93-0aba-4efe-b6f8-87702fbd5e96", "name": "", "x": 38.61593370015664, "y": -122.45611332456588, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2f20ace2-5ec8-4451-b7e7-66f46c2c487b", "name": "p1rdt6276lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8daf5a93-0aba-4efe-b6f8-87702fbd5e96"}}}}, {"uuid": "cb93529c-6913-4fbe-a725-7e4dee686cdb", "name": "", "x": 38.616214343979955, "y": -122.45638463812467, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2c63d163-75bd-4d91-bcfa-229a2e331b1f", "name": "p1rlv13057", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb93529c-6913-4fbe-a725-7e4dee686cdb"}}}}, {"uuid": "ac857cdd-f51e-4fa1-9097-01222c65d188", "name": "", "x": 38.61560758048402, "y": -122.45574597720416, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8d2fa164-4c03-4bcd-a386-749ccd4e9001", "name": "p1rlv13062", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ac857cdd-f51e-4fa1-9097-01222c65d188"}}}}, {"uuid": "59b0c5c4-2dde-4be1-92d4-fc14c7f28bfc", "name": "", "x": 38.61608078908832, "y": -122.45806664881565, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e582b04d-a8d8-4ee9-8576-1e5941623c0b", "name": "p1rdt6277lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59b0c5c4-2dde-4be1-92d4-fc14c7f28bfc"}}}}, {"uuid": "ea6ecbce-6597-489c-806f-0b38415136ee", "name": "", "x": 38.616096280398985, "y": -122.45813147961287, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a1779b5b-1a6c-4511-9d4b-88026b430173", "name": "p1rlv13059", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea6ecbce-6597-489c-806f-0b38415136ee"}}}}, {"uuid": "b3dc1c19-d603-4d73-8550-c2b4745ed0ab", "name": "", "x": 38.616472312390336, "y": -122.45760251208678, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2b37eabc-787a-491f-bc4f-956f43a862ff", "name": "p1rdt6278lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b3dc1c19-d603-4d73-8550-c2b4745ed0ab"}}}}, {"uuid": "88ff6605-6274-48d5-a8df-b913f605e687", "name": "", "x": 38.61659895813833, "y": -122.45770269368248, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8767a040-da31-48d9-9473-0941856bcedc", "name": "p1rlv13060", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "88ff6605-6274-48d5-a8df-b913f605e687"}}}}, {"uuid": "d35605b8-f529-4dd5-ae8a-7cd432ad68bb", "name": "", "x": 38.635969271978226, "y": -122.41468609161443, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3a38eb6d-a625-42a1-95f6-bbf078d1447a", "name": "p1rdt6345lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d35605b8-f529-4dd5-ae8a-7cd432ad68bb"}}}}, {"uuid": "4016c322-b0a6-4180-bc76-3154deee1dad", "name": "", "x": 38.63598364556035, "y": -122.41473687445114, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c29c3206-b71d-41d1-8ad7-a693c8c25d4d", "name": "p1rlv13185", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4016c322-b0a6-4180-bc76-3154deee1dad"}}}}, {"uuid": "6cb57e62-5516-46bd-a1bd-16b0ff15d7fd", "name": "", "x": 38.638887372960305, "y": -122.42670366638174, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e40008af-ff50-42bd-8897-f663c27a436f", "name": "p1rdt6347lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6cb57e62-5516-46bd-a1bd-16b0ff15d7fd"}}}}, {"uuid": "e79a71dd-ab3c-4e4f-b0da-a0a3d2960fd9", "name": "", "x": 38.63887629434703, "y": -122.42675582564294, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ffbd17b6-b1a2-4e55-9052-67a84419bb9d", "name": "p1rlv13187", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e79a71dd-ab3c-4e4f-b0da-a0a3d2960fd9"}}}}, {"uuid": "effbfb8c-623e-49b9-a2a9-7c2b94ad9651", "name": "", "x": 38.63741237955581, "y": -122.41088141259655, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d84ac329-f314-41be-a2ee-89bc74789a18", "name": "p1rdt6348lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "effbfb8c-623e-49b9-a2a9-7c2b94ad9651"}}}}, {"uuid": "b0eb5a62-8284-4550-a2a3-f5fe56a755e1", "name": "", "x": 38.63776633109597, "y": -122.41081354844057, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "67ffcd9f-ba90-4da7-b3b6-46310e321590", "name": "p1rlv13188", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b0eb5a62-8284-4550-a2a3-f5fe56a755e1"}}}}, {"uuid": "05557a96-5314-4ed4-b7f0-eb914262c728", "name": "", "x": 38.63725354679822, "y": -122.41099009448936, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3f6d09e9-3592-4560-8626-0d7cb71ca56a", "name": "p1rlv13191", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "05557a96-5314-4ed4-b7f0-eb914262c728"}}}}, {"uuid": "6b814f18-4e8f-4dc6-a472-a092ced2af22", "name": "", "x": 38.63720762179658, "y": -122.41081812238316, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2e3e10c6-6ce2-4efa-be50-80e8b9bffe29", "name": "p1rlv13195", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6b814f18-4e8f-4dc6-a472-a092ced2af22"}}}}, {"uuid": "723dc179-b0d4-453a-a37d-3602709a2654", "name": "", "x": 38.63750552004759, "y": -122.4109190928234, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2cdd7c49-e758-4009-8db5-d0b5748f919c", "name": "p1rlv13201", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "723dc179-b0d4-453a-a37d-3602709a2654"}}}}, {"uuid": "855b9038-87f7-4d5d-b419-c8e7d259873c", "name": "", "x": 38.64190459200407, "y": -122.42077252919503, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fdfa0310-7dc5-4181-a64e-cc2522370547", "name": "p1rdt6349lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "855b9038-87f7-4d5d-b419-c8e7d259873c"}}}}, {"uuid": "a02fd54c-e29a-4c35-bbfb-ae25adf08bd4", "name": "", "x": 38.6420159229094, "y": -122.42084455001161, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "268361f6-d5ac-4002-80a6-f56f3b33599c", "name": "p1rlv13189", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a02fd54c-e29a-4c35-bbfb-ae25adf08bd4"}}}}, {"uuid": "06e6e604-e32f-43a8-a8e3-cb370f644ed3", "name": "", "x": 38.636198973427064, "y": -122.41018025968964, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0138b892-d18e-497c-9857-c4d5676deac2", "name": "p1rdt6350lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "06e6e604-e32f-43a8-a8e3-cb370f644ed3"}}}}, {"uuid": "1854b823-e587-42c6-9322-3428ce6ce9b2", "name": "", "x": 38.63617297274995, "y": -122.41013766183407, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3dbc593c-3949-4fa4-8738-d92540dbf998", "name": "p1rlv13190", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1854b823-e587-42c6-9322-3428ce6ce9b2"}}}}, {"uuid": "2166852d-80a3-428b-8d53-254aa32d4239", "name": "", "x": 38.634295860150814, "y": -122.41680227142706, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "015322ae-7712-488f-9569-33fc785e4f62", "name": "p1rdt6353lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2166852d-80a3-428b-8d53-254aa32d4239"}}}}, {"uuid": "7e881470-549e-48ee-adf6-abc91359e7f6", "name": "", "x": 38.634321357711805, "y": -122.41675918344534, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2d5ba889-d8f7-44ca-86b2-40939fa95df2", "name": "p1rlv13194", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7e881470-549e-48ee-adf6-abc91359e7f6"}}}}, {"uuid": "527d288f-2043-4812-9466-eedc4d8ab423", "name": "", "x": 38.63633728483974, "y": -122.42060300525114, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0fd10fd1-b67f-422c-b976-582e2bb4e0ec", "name": "p1rdm13558", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "527d288f-2043-4812-9466-eedc4d8ab423"}}}}, {"uuid": "1dca3f46-9489-4e6b-8c7c-ebe7d8fde286", "name": "", "x": 38.63688282698339, "y": -122.41975985681357, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "27013147-3d8f-4d75-a7a7-24457dc6d62a", "name": "p1rlv13196", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1dca3f46-9489-4e6b-8c7c-ebe7d8fde286"}}}}, {"uuid": "8cc62ace-11fa-4dd3-a1d9-b50e2ad0e7a0", "name": "", "x": 38.63646127576851, "y": -122.42073591122158, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f06a08bd-05ea-4914-b0d0-07cd0e83bfbc", "name": "p1rdt6354lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8cc62ace-11fa-4dd3-a1d9-b50e2ad0e7a0"}}}}, {"uuid": "c604b145-f503-41b1-9dc4-2f31cad75e9b", "name": "", "x": 38.63663597134643, "y": -122.42086486559913, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "786efaf4-c281-4def-9a4e-2ffbf37e08be", "name": "p1rdm13559", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c604b145-f503-41b1-9dc4-2f31cad75e9b"}}}}, {"uuid": "a95d2d49-eb75-4e81-a97c-4fd013ac2e53", "name": "", "x": 38.63697733189416, "y": -122.42007329323263, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fed30a3f-12a5-4545-b5d5-5c13a131a256", "name": "p1rlv13200", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a95d2d49-eb75-4e81-a97c-4fd013ac2e53"}}}}, {"uuid": "a8acb079-e050-43db-b97d-4a7c0aed2fdf", "name": "", "x": 38.64208811872309, "y": -122.42143750947257, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f1d14a79-4d18-43fe-8790-57ea9adf83a8", "name": "p1rdt6355lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8acb079-e050-43db-b97d-4a7c0aed2fdf"}}}}, {"uuid": "ecb37bad-3593-475c-827e-ec4e7777c96f", "name": "", "x": 38.64203661805849, "y": -122.42138444352005, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7b077d0f-74ec-4a04-8eb8-cf02ad16077d", "name": "p1rlv13197", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ecb37bad-3593-475c-827e-ec4e7777c96f"}}}}, {"uuid": "76c93f4d-c02a-44ff-b4b5-6f417c2b54a4", "name": "", "x": 38.637121227961, "y": -122.41980119772418, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "548724aa-110a-428f-b71a-acdf0051dc39", "name": "p1rdt6356lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "76c93f4d-c02a-44ff-b4b5-6f417c2b54a4"}}}}, {"uuid": "a6b8ea32-a985-4859-ab59-f6d7b0d0da63", "name": "", "x": 38.6370952307597, "y": -122.41975859580664, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ad7545fb-8a41-4ed7-a178-e90f19bfa9d5", "name": "p1rlv13199", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a6b8ea32-a985-4859-ab59-f6d7b0d0da63"}}}}, {"uuid": "ddfdec26-8ee3-49e0-9a72-cb7236e92342", "name": "", "x": 38.625625701122225, "y": -122.46597233146389, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e36cfaaa-3996-4cc6-aa4f-170f20c5d1e0", "name": "p1rdt6409lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ddfdec26-8ee3-49e0-9a72-cb7236e92342"}}}}, {"uuid": "b2a436d9-b0f8-48e2-aeb6-3e0d1f57befc", "name": "", "x": 38.625599720610666, "y": -122.46592971942587, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "473b080b-1412-40dc-a452-09d43a462098", "name": "p1rlv13316", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b2a436d9-b0f8-48e2-aeb6-3e0d1f57befc"}}}}, {"uuid": "0b946f90-2e39-4fd3-b0ba-8544c409d55c", "name": "", "x": 38.578857638178405, "y": -122.51077785799649, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7", "name": "p1rdt6498lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0b946f90-2e39-4fd3-b0ba-8544c409d55c"}}}}, {"uuid": "1d821ba2-72a7-4d64-b2d1-a334142c0759", "name": "", "x": 38.57893830123369, "y": -122.5108886242969, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "353889fb-da44-4cf8-ae0e-d20541f36d7e", "name": "p1rlv13597", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d821ba2-72a7-4d64-b2d1-a334142c0759"}}}}, {"uuid": "467c88e4-d134-4fa8-9e81-73a5a3be69ab", "name": "", "x": 38.57885671632947, "y": -122.51077437155158, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6015a810-79da-480f-b1a1-fd6a4abdba37", "name": "p1rlv13631", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "467c88e4-d134-4fa8-9e81-73a5a3be69ab"}}}}, {"uuid": "d9c52a80-2697-4d5e-914c-a915bfd7285f", "name": "", "x": 38.579117623107756, "y": -122.51066927591476, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f92273c9-90b8-4819-b036-9d69afb5aed6", "name": "p1rlv13696", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d9c52a80-2697-4d5e-914c-a915bfd7285f"}}}}, {"uuid": "b7b04bac-1b23-4b18-bc24-f9ee42054770", "name": "", "x": 38.57882896139523, "y": -122.51060235083729, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1fe3c958-296f-4b51-8b2b-74bb34ddb5a6", "name": "p1rlv13702", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b7b04bac-1b23-4b18-bc24-f9ee42054770"}}}}, {"uuid": "9aaf3362-751e-4e7d-ab80-e0243d0b72f8", "name": "", "x": 38.578814411150496, "y": -122.51075566702022, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c9efacf5-5b96-4670-b6f1-dc398485cde9", "name": "p1rlv13703", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9aaf3362-751e-4e7d-ab80-e0243d0b72f8"}}}}, {"uuid": "1d16ca37-4d9e-4caa-adb7-d56ca9da816a", "name": "", "x": 38.57878534253772, "y": -122.51094706458596, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "457c6c9d-5020-4cf3-9c1e-c36012a619d2", "name": "p1rlv13724", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d16ca37-4d9e-4caa-adb7-d56ca9da816a"}}}}, {"uuid": "8390b3b1-225b-4c6a-896a-3fb330512d9c", "name": "", "x": 38.58016810697636, "y": -122.51189059526916, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ce39f1f5-b784-4919-9d3d-f6149f39595e", "name": "p1rdm13996", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8390b3b1-225b-4c6a-896a-3fb330512d9c"}}}}, {"uuid": "7d953cf8-edae-40e4-91a0-6f7cb240f34b", "name": "", "x": 38.5798974214499, "y": -122.5118120619195, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "59953c2f-244e-4bb8-ab24-b28d82b195e1", "name": "p1rlv13598", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7d953cf8-edae-40e4-91a0-6f7cb240f34b"}}}}, {"uuid": "93963b59-7c3d-4dd6-ac3e-0ad59a026255", "name": "", "x": 38.57980967492142, "y": -122.51170181808382, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aeea20e0-9908-4f28-aa5d-068244e3861b", "name": "p1rlv13626", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "93963b59-7c3d-4dd6-ac3e-0ad59a026255"}}}}, {"uuid": "1ad6b39f-4277-41f1-9a59-2045f78b2e42", "name": "", "x": 38.57989689465763, "y": -122.51168577702153, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cc33013a-6a90-46a7-9127-f32288111c14", "name": "p1rlv13635", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1ad6b39f-4277-41f1-9a59-2045f78b2e42"}}}}, {"uuid": "5eeeb5e6-f8c4-4529-a6ba-bfc863eb4f1e", "name": "", "x": 38.579743504522455, "y": -122.51164089263591, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7b3e7495-7732-42ce-8d53-a5f1b7383ce4", "name": "p1rlv20504", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5eeeb5e6-f8c4-4529-a6ba-bfc863eb4f1e"}}}}, {"uuid": "c3a02a5e-5c58-4beb-a733-0ec716c360ff", "name": "", "x": 38.5802287989983, "y": -122.5117616084684, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bb05d831-1556-4f56-8065-d9d16657caa3", "name": "p1rdt6499lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c3a02a5e-5c58-4beb-a733-0ec716c360ff"}}}}, {"uuid": "a99ef52b-4365-4bea-9c0d-269b26323d76", "name": "", "x": 38.58030555227583, "y": -122.51158054354175, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f85240e6-bbbe-4b90-8419-a00a3ca9613f", "name": "p1rdm13999", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a99ef52b-4365-4bea-9c0d-269b26323d76"}}}}, {"uuid": "3faf2268-1c3c-4bf5-bd88-7c9001bd6c12", "name": "", "x": 38.57988706857757, "y": -122.51149067050049, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3839c291-3f45-46c3-973f-6a9615fcf81b", "name": "p1rlv13698", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3faf2268-1c3c-4bf5-bd88-7c9001bd6c12"}}}}, {"uuid": "149c7dea-71cc-4482-83fc-8194d3d50a88", "name": "", "x": 38.58035293960693, "y": -122.51140410649425, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ea740eb8-42c6-4417-97d6-7c73f1fc2bc8", "name": "p1rdm14000", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "149c7dea-71cc-4482-83fc-8194d3d50a88"}}}}, {"uuid": "108611d9-9d63-47a3-aae9-ef2cdacf6787", "name": "", "x": 38.580220356921046, "y": -122.5114539704366, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "642597e6-fe60-442f-b356-2be6f21677b2", "name": "p1rlv13726", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "108611d9-9d63-47a3-aae9-ef2cdacf6787"}}}}, {"uuid": "17774d75-030e-4f6b-b9fc-a5ea4e90bb77", "name": "", "x": 38.58083948102145, "y": -122.5097420033343, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a20a4242-8a76-49f3-9bf5-3d7aaf751cdc", "name": "p1rdt6500lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "17774d75-030e-4f6b-b9fc-a5ea4e90bb77"}}}}, {"uuid": "fca68e74-8079-476d-8e08-9403ecc91752", "name": "", "x": 38.58075318348773, "y": -122.50956749241811, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "216537dd-ea7b-461c-b821-99491c41b7f0", "name": "p1rlv13613", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fca68e74-8079-476d-8e08-9403ecc91752"}}}}, {"uuid": "946b4384-4111-4b9d-baa0-3d02c5634209", "name": "", "x": 38.58094565510626, "y": -122.50948667802179, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "83aa4266-e486-4e00-a09b-7bcdc613a9b5", "name": "p1rdm14004", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "946b4384-4111-4b9d-baa0-3d02c5634209"}}}}, {"uuid": "98f2af76-03e7-4ca3-8482-85d5bb432b8c", "name": "", "x": 38.580815639747385, "y": -122.50941781578797, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f823a90c-effd-489c-9e0a-c110ccb7b9e8", "name": "p1rlv13618", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "98f2af76-03e7-4ca3-8482-85d5bb432b8c"}}}}, {"uuid": "273b3d0e-7740-4807-828e-a1e37aa9d0e9", "name": "", "x": 38.58094199565767, "y": -122.50946287997223, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ff282b99-30bb-4c1d-acb9-02fafe241577", "name": "p1rdm14007", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "273b3d0e-7740-4807-828e-a1e37aa9d0e9"}}}}, {"uuid": "43d3fb88-4440-485a-a7d4-1cfa651312fb", "name": "", "x": 38.580561868772826, "y": -122.50907511585717, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1c61a243-7736-46a0-a950-7cc811381158", "name": "p1rlv13653", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "43d3fb88-4440-485a-a7d4-1cfa651312fb"}}}}, {"uuid": "57b109ad-77d4-4e35-8c6a-2d1b67884755", "name": "", "x": 38.58103524253283, "y": -122.50935977822509, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3c0ae3b1-ac0d-43c9-9a1e-c73bd10e3ad8", "name": "p1rdm14002", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "57b109ad-77d4-4e35-8c6a-2d1b67884755"}}}}, {"uuid": "974a1a48-d33c-48aa-aeb5-230ce3105a1c", "name": "", "x": 38.58069699573112, "y": -122.50906271510544, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d2a60818-4310-4100-9aa8-35ef37aa5f40", "name": "p1rlv13599", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "974a1a48-d33c-48aa-aeb5-230ce3105a1c"}}}}, {"uuid": "fabd8bb6-7edf-42be-8e6b-5663ec1f9863", "name": "", "x": 38.58115055848325, "y": -122.50921129101727, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d576dffc-af75-488e-8c51-19aa726f0505", "name": "p1rdm14005", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fabd8bb6-7edf-42be-8e6b-5663ec1f9863"}}}}, {"uuid": "631cb3f9-1cef-4bac-96dc-ab0058dd06c9", "name": "", "x": 38.58066046743406, "y": -122.50894815487301, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "62a29ac5-7227-43b2-b602-b1189cc93839", "name": "p1rlv13648", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "631cb3f9-1cef-4bac-96dc-ab0058dd06c9"}}}}, {"uuid": "e50ab3f8-8db4-47ab-851d-95ec1d4566e7", "name": "", "x": 38.58075404919642, "y": -122.50977414282289, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7e5abf33-75a2-446f-9c6c-1f3384b78c24", "name": "p1rdm14008", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e50ab3f8-8db4-47ab-851d-95ec1d4566e7"}}}}, {"uuid": "45f7226f-8189-4fdd-986c-9f3171a508b2", "name": "", "x": 38.58080831157611, "y": -122.50981969761952, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4671f981-e26e-4f26-9698-7f9068ce6dec", "name": "p1rlv13687", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "45f7226f-8189-4fdd-986c-9f3171a508b2"}}}}, {"uuid": "4690aac7-835d-4f30-ae06-41a51aaf2b24", "name": "", "x": 38.580709327387154, "y": -122.50985481311328, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "592b8095-ba99-4993-a445-9af51fa89f57", "name": "p1rdm14009", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4690aac7-835d-4f30-ae06-41a51aaf2b24"}}}}, {"uuid": "c77d28e1-b011-4ecc-a915-17583b1adf98", "name": "", "x": 38.580745614457776, "y": -122.50991197100555, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "44aa3f37-e0db-4050-b47f-ac14b7fa6534", "name": "p1rlv13719", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c77d28e1-b011-4ecc-a915-17583b1adf98"}}}}, {"uuid": "810ea90d-e32b-4403-a753-626d87d2255b", "name": "", "x": 38.58065559384605, "y": -122.50993554454202, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33445b16-68bf-4606-8ac5-def4763fb95d", "name": "p1rdm14006", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "810ea90d-e32b-4403-a753-626d87d2255b"}}}}, {"uuid": "8cb81b56-81c0-4541-bf0e-8d99301e93e7", "name": "", "x": 38.58069192894027, "y": -122.51000418300181, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3310c14a-d1ee-4d0c-8428-d002703c61d5", "name": "p1rlv13652", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8cb81b56-81c0-4541-bf0e-8d99301e93e7"}}}}, {"uuid": "d5eb11ec-20a7-43a6-bcbe-8e80506573b5", "name": "", "x": 38.580115053283016, "y": -122.51211138251598, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923", "name": "p1rdt6501lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d5eb11ec-20a7-43a6-bcbe-8e80506573b5"}}}}, {"uuid": "e0c5a120-ac0a-43a9-80c0-9d910c4b0d14", "name": "", "x": 38.57996098198724, "y": -122.5119264394613, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "59ab6d81-a91c-4350-8f94-abe02e3e1555", "name": "p1rlv13600", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e0c5a120-ac0a-43a9-80c0-9d910c4b0d14"}}}}, {"uuid": "c9ff9645-8f59-4b3a-b2b6-f8365fc0a052", "name": "", "x": 38.58025012153835, "y": -122.51210817586814, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "29838633-5c95-4b73-8227-cfa7f4aedc32", "name": "p1rlv13606", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c9ff9645-8f59-4b3a-b2b6-f8365fc0a052"}}}}, {"uuid": "b28ac41e-68ec-478f-8f63-b7474b7cb521", "name": "", "x": 38.58018699193046, "y": -122.51209712213534, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a5e8caf4-4d81-4bbd-98df-6622c5ad0563", "name": "p1rlv13608", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b28ac41e-68ec-478f-8f63-b7474b7cb521"}}}}, {"uuid": "a75547f7-63ae-4c46-88ef-c390878cd28c", "name": "", "x": 38.580430450820984, "y": -122.5121299176103, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f693a1d2-5499-4810-9458-f205eda265fa", "name": "p1rlv13619", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a75547f7-63ae-4c46-88ef-c390878cd28c"}}}}, {"uuid": "36b4f113-3755-49cf-8d87-c2a79648b0d1", "name": "", "x": 38.58039473905232, "y": -122.51221052513978, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4540b2cb-ee21-4515-a7ca-fbca371f060d", "name": "p1rlv13622", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "36b4f113-3755-49cf-8d87-c2a79648b0d1"}}}}, {"uuid": "b1b116f3-0151-42b2-a8aa-ac02307e8906", "name": "", "x": 38.57999120125346, "y": -122.51201057019674, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "30c470ac-39d1-4379-9ae7-790d912bce2c", "name": "p1rlv13637", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b1b116f3-0151-42b2-a8aa-ac02307e8906"}}}}, {"uuid": "0870751c-5e1a-47c1-ab38-434e9da36a6c", "name": "", "x": 38.580262816627275, "y": -122.51171636414, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0b7d4c6f-98b5-4cec-b8a4-9311b5fc92bd", "name": "p1rdm14016", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0870751c-5e1a-47c1-ab38-434e9da36a6c"}}}}, {"uuid": "1221665c-1324-49ea-93f7-2780a566c268", "name": "", "x": 38.58050168270344, "y": -122.5119227801456, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "de45dc59-3e0a-4b33-8cf4-d5213b0140c1", "name": "p1rlv13683", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1221665c-1324-49ea-93f7-2780a566c268"}}}}, {"uuid": "16be71f9-5715-4ab6-8469-27d24af8c118", "name": "", "x": 38.58090324022768, "y": -122.51898480487121, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7682e9f7-1272-4781-b128-34c7329afe49", "name": "p1rdt6502lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "16be71f9-5715-4ab6-8469-27d24af8c118"}}}}, {"uuid": "a8cffd85-3289-411b-aba3-fe19b3957850", "name": "", "x": 38.5809550747074, "y": -122.51912974155378, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "91953a27-bbc7-494a-bec2-a12b4c0f6af6", "name": "p1rlv13601", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8cffd85-3289-411b-aba3-fe19b3957850"}}}}, {"uuid": "d1656f14-981b-475f-950b-06cfa738b307", "name": "", "x": 38.580818625476454, "y": -122.51882066658119, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "987b05d5-9bb9-434d-98b3-623ee5014870", "name": "p1rlv13634", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1656f14-981b-475f-950b-06cfa738b307"}}}}, {"uuid": "576e3987-1203-4abc-b2aa-d321607a4c09", "name": "", "x": 38.579472359669175, "y": -122.51077416509521, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "387e7785-8d40-4ddd-8c2b-14a83d4e7401", "name": "p1rdt6505lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "576e3987-1203-4abc-b2aa-d321607a4c09"}}}}, {"uuid": "117edca2-b846-4d13-9e09-6fbfb439c0a0", "name": "", "x": 38.579542563399, "y": -122.5109993333898, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c9b83bdf-b564-4997-bfc7-1be2f2e58199", "name": "p1rlv13604", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "117edca2-b846-4d13-9e09-6fbfb439c0a0"}}}}, {"uuid": "ee47ad29-c529-4e7b-a7dd-b2020a1a2885", "name": "", "x": 38.579306628363845, "y": -122.51061059015836, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c39dc6f1-08b5-4bc1-a6ae-be0076af56aa", "name": "p1rlv13605", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ee47ad29-c529-4e7b-a7dd-b2020a1a2885"}}}}, {"uuid": "0dec7af5-bd71-4eb9-b72c-26a08ebea42c", "name": "", "x": 38.57932426767413, "y": -122.51051862504016, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a7be734c-88e2-42c1-8061-f4632bd05759", "name": "p1rlv13654", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0dec7af5-bd71-4eb9-b72c-26a08ebea42c"}}}}, {"uuid": "2116346b-bc4a-4280-8b61-ba47b65fca49", "name": "", "x": 38.57968631853392, "y": -122.51089503204967, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8df1a69e-5b18-4eef-ab60-543a97257297", "name": "p1rlv13676", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2116346b-bc4a-4280-8b61-ba47b65fca49"}}}}, {"uuid": "e3d45cb8-548e-48b2-8d6b-213cd2b0dc2e", "name": "", "x": 38.579406764605274, "y": -122.51085100517132, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a822fdb0-b531-49b0-89da-b517e5ae6e3a", "name": "p1rlv13715", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e3d45cb8-548e-48b2-8d6b-213cd2b0dc2e"}}}}, {"uuid": "b166c449-a23e-4a12-b4cc-82d2661db536", "name": "", "x": 38.57531283222509, "y": -122.51744138284937, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f5844baa-5e0f-4edd-9122-fe4255adad0b", "name": "p1rdt6507lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b166c449-a23e-4a12-b4cc-82d2661db536"}}}}, {"uuid": "5eb22c70-3464-4dba-a0ef-ad656df3001f", "name": "", "x": 38.57505206910961, "y": -122.5168960568265, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "17d92377-b4f1-4194-89cd-130bddb9b77c", "name": "p1rlv13610", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5eb22c70-3464-4dba-a0ef-ad656df3001f"}}}}, {"uuid": "09e5d099-7b4a-4e2d-b26a-9262b490061d", "name": "", "x": 38.57545948963316, "y": -122.51735253068708, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5a2f5fad-c0a9-4f62-a318-ef00c0d4f470", "name": "p1rdm14031", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "09e5d099-7b4a-4e2d-b26a-9262b490061d"}}}}, {"uuid": "143b6497-07f4-4643-9cde-7468e190cad4", "name": "", "x": 38.57508745244601, "y": -122.5167350997636, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e5ab8bce-7c02-4c7b-962e-3fb44a3ab7a9", "name": "p1rlv13712", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "143b6497-07f4-4643-9cde-7468e190cad4"}}}}, {"uuid": "90a1cfbd-701d-4453-a895-51357736c657", "name": "", "x": 38.58028384394968, "y": -122.51110778698562, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5", "name": "p1rdt6508lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "90a1cfbd-701d-4453-a895-51357736c657"}}}}, {"uuid": "86ae937a-a60c-4ae1-a7c8-387f40e1eb91", "name": "", "x": 38.58035447758333, "y": -122.51120048333938, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "630b2a63-622f-4f78-8390-77c69ba7e393", "name": "p1rlv13611", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "86ae937a-a60c-4ae1-a7c8-387f40e1eb91"}}}}, {"uuid": "56eecfee-9e33-4531-a77b-2f2f7c11b0b4", "name": "", "x": 38.58037206939203, "y": -122.51109703650175, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5868c24b-2a58-459b-8650-a6072241aca8", "name": "p1rlv13666", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "56eecfee-9e33-4531-a77b-2f2f7c11b0b4"}}}}, {"uuid": "061c6dbf-e40a-4035-a3a4-ba8cb2fe1a04", "name": "", "x": 38.57994856849807, "y": -122.51111138826255, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f777bc74-e6f3-4e80-bb72-0764964db21e", "name": "p1rlv13685", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "061c6dbf-e40a-4035-a3a4-ba8cb2fe1a04"}}}}, {"uuid": "f562c711-b88d-409b-8e2e-eb3672b70456", "name": "", "x": 38.58024590590882, "y": -122.51109789179142, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aa7a324e-d367-49a5-820a-b18e72243265", "name": "p1rlv13701", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f562c711-b88d-409b-8e2e-eb3672b70456"}}}}, {"uuid": "2d927b29-01ab-4d50-a650-33eccd1a79d9", "name": "", "x": 38.5799747881709, "y": -122.51091603723427, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "286623b3-af08-4a60-896a-1f5b85fe04a5", "name": "p1rlv13707", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2d927b29-01ab-4d50-a650-33eccd1a79d9"}}}}, {"uuid": "063db81f-f1ad-43f7-88ab-eff9687a417b", "name": "", "x": 38.58041348455226, "y": -122.51100123505434, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "572123ef-d255-42a9-9c61-95d99aaff775", "name": "p1rdm14033", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "063db81f-f1ad-43f7-88ab-eff9687a417b"}}}}, {"uuid": "61501da2-c1a2-4b94-b083-88cfce749eb4", "name": "", "x": 38.58026296994941, "y": -122.51086815956218, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c808261e-a49e-4954-bdc4-a8b63d0ee25b", "name": "p1rlv13651", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "61501da2-c1a2-4b94-b083-88cfce749eb4"}}}}, {"uuid": "4b2e985c-70d7-4dd4-a2d1-1e17ef074d29", "name": "", "x": 38.58047071823679, "y": -122.5109815591307, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9657a993-0005-4ffc-8c9f-18e80a491070", "name": "p1rlv13728", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4b2e985c-70d7-4dd4-a2d1-1e17ef074d29"}}}}, {"uuid": "b204f9a6-7874-4654-b240-9f95ec20a3a3", "name": "", "x": 38.5802039677474, "y": -122.51142297137118, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f817a28f-c650-4eb4-84c0-751fe5053c75", "name": "p1rdt6509lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b204f9a6-7874-4654-b240-9f95ec20a3a3"}}}}, {"uuid": "3d63084b-d34f-45cc-acbb-fd7c7f5a12e0", "name": "", "x": 38.58031071328429, "y": -122.51151076251458, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6eda3e97-a618-41ab-ae55-ba67f6bb0234", "name": "p1rlv13612", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3d63084b-d34f-45cc-acbb-fd7c7f5a12e0"}}}}, {"uuid": "6497e293-e1f6-435a-bce1-81d85ff0cc34", "name": "", "x": 38.58038280670725, "y": -122.51151027418985, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e47df44a-79f1-423b-a295-c9c354795895", "name": "p1rlv13628", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6497e293-e1f6-435a-bce1-81d85ff0cc34"}}}}, {"uuid": "1c58cbeb-4ec0-4ca2-ac37-c2b219acb7ac", "name": "", "x": 38.58025300210597, "y": -122.51162119713781, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b65a5fd-f38e-447a-a51a-e7a214ba6bcc", "name": "p1rdm14041", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1c58cbeb-4ec0-4ca2-ac37-c2b219acb7ac"}}}}, {"uuid": "fde75755-8187-4131-a5d4-4019004aa484", "name": "", "x": 38.580112887543876, "y": -122.51161542971188, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3bd69c55-2141-4c8e-becf-efa4bff8a63e", "name": "p1rlv13627", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fde75755-8187-4131-a5d4-4019004aa484"}}}}, {"uuid": "e4998f27-5b4d-4c16-ab05-f4dac5151539", "name": "", "x": 38.580175969292135, "y": -122.51161500252242, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "122e0772-7de6-4117-b1d3-caafbbbc8e22", "name": "p1rlv13659", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e4998f27-5b4d-4c16-ab05-f4dac5151539"}}}}, {"uuid": "b4d08695-c287-4103-a10a-c5f5e7de9242", "name": "", "x": 38.58035042352862, "y": -122.51170963762122, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3d6fd13-2f04-4f23-97a3-cdf99159174c", "name": "p1rlv13660", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b4d08695-c287-4103-a10a-c5f5e7de9242"}}}}, {"uuid": "d88a5ec5-7a6d-401d-9412-e96155fdde62", "name": "", "x": 38.58048939096295, "y": -122.51181556577525, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f9aa7e62-8974-4ef0-aa5a-bcd545245aea", "name": "p1rlv13677", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d88a5ec5-7a6d-401d-9412-e96155fdde62"}}}}, {"uuid": "75d80de5-97ee-4db0-a01b-be74d82659b4", "name": "", "x": 38.58024561739162, "y": -122.51180603102428, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1252c522-5ced-4f4c-908c-f58501ad6f92", "name": "p1rdm14040", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "75d80de5-97ee-4db0-a01b-be74d82659b4"}}}}, {"uuid": "72b5ddf0-cdde-4895-9453-c7f24c784a2d", "name": "", "x": 38.580128349144296, "y": -122.51168024007933, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a5746d1-24a6-4ae4-b5dc-cef23b56660d", "name": "p1rlv13624", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "72b5ddf0-cdde-4895-9453-c7f24c784a2d"}}}}, {"uuid": "bd429e21-2c9a-44b9-8545-365dc7b0f4b3", "name": "", "x": 38.580312054434806, "y": -122.51183221682473, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6097c903-70fc-4635-a66c-fee2243ba545", "name": "p1rlv13721", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bd429e21-2c9a-44b9-8545-365dc7b0f4b3"}}}}, {"uuid": "8afa5cca-cf73-4ba5-8115-0096b37ddc9f", "name": "", "x": 38.580296766700286, "y": -122.51131091827517, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9be8942c-8459-4c1d-a3b0-a89ee5cced4e", "name": "p1rdm14043", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8afa5cca-cf73-4ba5-8115-0096b37ddc9f"}}}}, {"uuid": "29f2bebe-42ef-47a3-a9af-271923a11423", "name": "", "x": 38.5799938666379, "y": -122.51116848511225, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2b3fe33f-fdcf-42f5-be08-8da15a4d4958", "name": "p1rlv13633", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "29f2bebe-42ef-47a3-a9af-271923a11423"}}}}, {"uuid": "c53689db-2b77-4c25-b14e-1fb5d913ade2", "name": "", "x": 38.5799041333983, "y": -122.51126093949996, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "54887ca7-ae23-42d0-a715-aed8baa38ade", "name": "p1rlv13663", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c53689db-2b77-4c25-b14e-1fb5d913ade2"}}}}, {"uuid": "9ab32b8a-c150-4705-a799-5d52c7489517", "name": "", "x": 38.580282671809215, "y": -122.5112698550077, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32bec8ad-b312-4502-a2a1-6a4c9b2dd87a", "name": "p1rlv13672", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9ab32b8a-c150-4705-a799-5d52c7489517"}}}}, {"uuid": "36454f81-98b1-4198-a09a-d38e5d78e1a2", "name": "", "x": 38.58020166258251, "y": -122.51129336562714, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60fe0a16-aa4d-4fe8-9f39-81bfa13b505f", "name": "p1rlv13686", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "36454f81-98b1-4198-a09a-d38e5d78e1a2"}}}}, {"uuid": "0a18e2cb-16df-4c1c-81b6-dbb05c76fbe1", "name": "", "x": 38.57904493503404, "y": -122.51120538916284, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5d62fe3b-7644-46d1-8a15-e86d95ae8b2a", "name": "p1rdt6510lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a18e2cb-16df-4c1c-81b6-dbb05c76fbe1"}}}}, {"uuid": "f3325332-f006-4607-a16a-4f00a69b75f0", "name": "", "x": 38.5789032137621, "y": -122.51111847447159, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3de8b994-01ba-4eae-b9cf-7fb174d32355", "name": "p1rlv13614", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f3325332-f006-4607-a16a-4f00a69b75f0"}}}}, {"uuid": "ba7db288-60ce-4c65-a595-a56e7f503a45", "name": "", "x": 38.5791652716089, "y": -122.51128890787042, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "85b910cd-def8-41d8-ad47-3c074a54ad8d", "name": "p1rlv13680", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ba7db288-60ce-4c65-a595-a56e7f503a45"}}}}, {"uuid": "82223b46-a986-42df-938c-4dbe70b435f8", "name": "", "x": 38.57913785305847, "y": -122.51119724847887, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "58e2b774-ac04-435e-9e03-573b3aa94cfb", "name": "p1rlv20467", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "82223b46-a986-42df-938c-4dbe70b435f8"}}}}, {"uuid": "50b458e0-d55c-4e4a-843a-96e5759c930a", "name": "", "x": 38.58046789565426, "y": -122.5107496740826, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5702c88a-92e4-40ce-8a51-684fe6662789", "name": "p1rdt6512lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "50b458e0-d55c-4e4a-843a-96e5759c930a"}}}}, {"uuid": "cd9c9ac2-fe35-4dc5-99b4-d2982e164998", "name": "", "x": 38.58036118662805, "y": -122.51064935740038, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "850d5b69-14cf-4a18-8cb0-4f1b3033b0aa", "name": "p1rlv13616", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cd9c9ac2-fe35-4dc5-99b4-d2982e164998"}}}}, {"uuid": "3ebbb7c2-14b8-4efd-a122-9e8fedbeb88b", "name": "", "x": 38.58035246292223, "y": -122.510718301644, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "20009de0-cbe7-4b4f-a046-425a6ae71925", "name": "p1rlv13643", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3ebbb7c2-14b8-4efd-a122-9e8fedbeb88b"}}}}, {"uuid": "4bb71e49-0e3e-4855-95cd-ac756bef5eca", "name": "", "x": 38.58049679372011, "y": -122.51075176502394, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3fe0466e-cce5-4c6c-b13f-cedd349b6944", "name": "p1rlv13646", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4bb71e49-0e3e-4855-95cd-ac756bef5eca"}}}}, {"uuid": "6c71be1f-dd4f-4c0a-9aba-36a2ddb80c23", "name": "", "x": 38.5801239858384, "y": -122.51063551633443, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3fa2041e-34c4-4f1f-a329-74969c3da75f", "name": "p1rlv13650", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c71be1f-dd4f-4c0a-9aba-36a2ddb80c23"}}}}, {"uuid": "26581ec2-f996-4c6a-944b-6969311a7b5b", "name": "", "x": 38.580207508083255, "y": -122.510535591989, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e290046b-c936-4f51-b4ef-632bf572ab7f", "name": "p1rlv13725", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "26581ec2-f996-4c6a-944b-6969311a7b5b"}}}}, {"uuid": "91b7f1e8-60ef-4282-9431-17ad4a4ed438", "name": "", "x": 38.580513953094915, "y": -122.51054499300294, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e3ed4387-9ecb-43c4-a392-e72bc5cb32b6", "name": "p1rdm14062", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "91b7f1e8-60ef-4282-9431-17ad4a4ed438"}}}}, {"uuid": "bff6a849-e000-42dd-a1ca-7d6cef0fe830", "name": "", "x": 38.580216231682456, "y": -122.51046664786318, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "70cf02cc-8f1b-48ab-b9e6-50c3e58ad9ae", "name": "p1rlv13664", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bff6a849-e000-42dd-a1ca-7d6cef0fe830"}}}}, {"uuid": "5fd72616-7318-4cb3-8643-7fa32865504e", "name": "", "x": 38.58042383633111, "y": -122.5105456046176, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60f08cde-51d3-4b51-9ab5-b61c8043950f", "name": "p1rlv13681", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5fd72616-7318-4cb3-8643-7fa32865504e"}}}}, {"uuid": "55257008-f143-4a2f-b906-8ce95b1b534f", "name": "", "x": 38.58052339680616, "y": -122.51064825672786, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fdbfe616-f51f-416a-94ce-6e676d300226", "name": "p1rlv13717", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "55257008-f143-4a2f-b906-8ce95b1b534f"}}}}, {"uuid": "23176e93-7407-464d-bc9a-52c55cf5818d", "name": "", "x": 38.5805590114763, "y": -122.5105446871946, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0fe37b51-0258-4812-9d96-3cc28c4bd55b", "name": "p1rlv20509", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "23176e93-7407-464d-bc9a-52c55cf5818d"}}}}, {"uuid": "ec46f3c7-03e2-4c29-94a5-0dc5d4fb3c9f", "name": "", "x": 38.580430683168224, "y": -122.51091156777555, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "485928ba-ff70-4be2-89ff-721ff82269fb", "name": "p1rdm14063", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ec46f3c7-03e2-4c29-94a5-0dc5d4fb3c9f"}}}}, {"uuid": "e216cc59-9ec4-4e42-9d09-5a00f7118d8d", "name": "", "x": 38.580046353830355, "y": -122.51078926317813, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b2f95b8b-190c-4df2-9dd2-daee5efde34b", "name": "p1rlv13671", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e216cc59-9ec4-4e42-9d09-5a00f7118d8d"}}}}, {"uuid": "248a8ebb-00ae-4a38-8a4f-10d10e9c56ef", "name": "", "x": 38.5800731009349, "y": -122.51072019695825, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "17936036-1191-4f91-bc12-2298db7b77e3", "name": "p1rlv13714", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "248a8ebb-00ae-4a38-8a4f-10d10e9c56ef"}}}}, {"uuid": "5aa22a9c-1ce1-4621-93e7-b53b9e38c72c", "name": "", "x": 38.580347829371135, "y": -122.51152987084961, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ad6bef77-8f39-43b4-b2d7-58aa6e45a60b", "name": "p1rdt6514lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5aa22a9c-1ce1-4621-93e7-b53b9e38c72c"}}}}, {"uuid": "10a7ab33-dca2-44a2-bc4d-09ca6dbebcfa", "name": "", "x": 38.57949879960493, "y": -122.51130960918293, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "80f60ab3-722f-4765-8b91-4fd0196171d7", "name": "p1rlv13623", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10a7ab33-dca2-44a2-bc4d-09ca6dbebcfa"}}}}, {"uuid": "ab4f132b-fd01-4949-81d2-a31a140fcc7e", "name": "", "x": 38.57935703047459, "y": -122.51121121339025, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bb3b4207-12ad-46e6-b4de-59149a46f8a1", "name": "p1rlv13716", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ab4f132b-fd01-4949-81d2-a31a140fcc7e"}}}}, {"uuid": "eefb9220-0cb8-4f72-885d-44b3115ed714", "name": "", "x": 38.58034931676033, "y": -122.51127026442917, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "395dac73-8fae-4718-a28c-191a76a298f2", "name": "p1rdm14072", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eefb9220-0cb8-4f72-885d-44b3115ed714"}}}}, {"uuid": "f49e9feb-241d-4ae8-a52f-be30473ffb53", "name": "", "x": 38.57957036570457, "y": -122.51118283635456, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "653bdc0d-5b21-4640-861b-b88ddb5c651a", "name": "p1rlv13640", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f49e9feb-241d-4ae8-a52f-be30473ffb53"}}}}, {"uuid": "31dfa6e7-23d1-4264-b514-b8738ffa1920", "name": "", "x": 38.58109531398495, "y": -122.50927974477071, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b92f8bcd-91ce-42bd-be69-0b43cb9d4122", "name": "p1rdt6515lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "31dfa6e7-23d1-4264-b514-b8738ffa1920"}}}}, {"uuid": "67a2a8dc-35a0-49b1-85b2-43530b524e93", "name": "", "x": 38.580433778313484, "y": -122.50861675365525, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4c667408-52a0-4258-8e93-557c94520a1e", "name": "p1rlv13625", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "67a2a8dc-35a0-49b1-85b2-43530b524e93"}}}}, {"uuid": "d632ea7f-fd46-4991-a3bf-ed80f588f4d9", "name": "", "x": 38.58052341301346, "y": -122.50850133423494, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7538ab85-10b4-4f60-98f8-179e954173b0", "name": "p1rlv19156", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d632ea7f-fd46-4991-a3bf-ed80f588f4d9"}}}}, {"uuid": "06e2a999-5f7e-46c8-bf9b-88a07f0a6653", "name": "", "x": 38.58046037950707, "y": -122.50851324468255, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fed6fcd4-3c97-4f62-a1a7-0b66394218e1", "name": "p1rlv19163", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "06e2a999-5f7e-46c8-bf9b-88a07f0a6653"}}}}, {"uuid": "df7ea0fc-8400-41d7-97a9-b5124ecf0dbb", "name": "", "x": 38.580379081602544, "y": -122.50846787535407, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ebd10471-ab4c-4cb7-a822-a83ef20e9854", "name": "p1rlv19165", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "df7ea0fc-8400-41d7-97a9-b5124ecf0dbb"}}}}, {"uuid": "71c50c0a-c945-48cf-90f3-ca1f580683fc", "name": "", "x": 38.58118341315065, "y": -122.50918052803313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c2659bd3-f6ca-4d74-87c8-f92596986cb5", "name": "p1rdm14075", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "71c50c0a-c945-48cf-90f3-ca1f580683fc"}}}}, {"uuid": "2943ec98-4018-405c-ac02-33c2cd62a6ce", "name": "", "x": 38.58079429345362, "y": -122.50862577812117, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1acad56e-b6d6-4fa7-a925-f242c1558eef", "name": "p1rlv13645", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2943ec98-4018-405c-ac02-33c2cd62a6ce"}}}}, {"uuid": "a3f4101a-c9ca-45b8-ab85-d07e7ec45422", "name": "", "x": 38.57910373167705, "y": -122.51042872774359, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "119a8559-8e6c-4314-9bbd-37ef3adde415", "name": "p1rdt6516lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a3f4101a-c9ca-45b8-ab85-d07e7ec45422"}}}}, {"uuid": "8578e75a-d652-46c2-a395-6865bcbad53c", "name": "", "x": 38.579216271561, "y": -122.51055379999012, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b4358536-b06f-486d-b336-3a8576b428d0", "name": "p1rlv13629", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8578e75a-d652-46c2-a395-6865bcbad53c"}}}}, {"uuid": "8432571b-e34a-43d5-9e64-26876c6c1f96", "name": "", "x": 38.57907136448223, "y": -122.51038257383402, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "db3908f7-94f5-43a7-a3de-1f6c9b72ebd4", "name": "p1rlv13638", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8432571b-e34a-43d5-9e64-26876c6c1f96"}}}}, {"uuid": "fc5a608f-136d-45a3-b9d3-55b3b6c1f5d9", "name": "", "x": 38.57899879076654, "y": -122.51026826026441, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "091b545a-eb31-4bea-a0a6-5aa9c7a8397f", "name": "p1rlv13692", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fc5a608f-136d-45a3-b9d3-55b3b6c1f5d9"}}}}, {"uuid": "40f54f9d-097d-45d1-a5d8-f1a1f6a5fc6b", "name": "", "x": 38.579225763250356, "y": -122.51066854219654, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5a230534-6927-4af8-ba54-6ab4c9c32d21", "name": "p1rlv13708", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "40f54f9d-097d-45d1-a5d8-f1a1f6a5fc6b"}}}}, {"uuid": "7af31148-260a-4af0-929e-efbf262969e1", "name": "", "x": 38.578028811911885, "y": -122.51471027861992, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5783bae9-2c74-473f-bf18-db40bc975409", "name": "p1rdt6517lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7af31148-260a-4af0-929e-efbf262969e1"}}}}, {"uuid": "44e91cd6-7c3b-4399-82ed-b6d033f98399", "name": "", "x": 38.577889883003294, "y": -122.51448911519815, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f474e4ba-6300-4014-afe9-c245e08cf3c5", "name": "p1rlv13630", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "44e91cd6-7c3b-4399-82ed-b6d033f98399"}}}}, {"uuid": "7bdf2223-6574-4b58-aadb-d8e61843899a", "name": "", "x": 38.577945523946006, "y": -122.51486759582244, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "822f96e6-61c5-455d-8a53-a494b49c9237", "name": "p1rdm14084", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7bdf2223-6574-4b58-aadb-d8e61843899a"}}}}, {"uuid": "a906ae70-357e-4896-84e5-143cc3bd8545", "name": "", "x": 38.577881918670876, "y": -122.51474173870584, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4eb10938-4b73-406c-bed4-0bd01e0bc20d", "name": "p1rlv13641", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a906ae70-357e-4896-84e5-143cc3bd8545"}}}}, {"uuid": "143669c5-e2c1-4511-91b3-1ce3d7e385ed", "name": "", "x": 38.575528992640834, "y": -122.51891559878237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d9b16b03-1922-4aeb-8e70-d0e1387fbcab", "name": "p1rdt6518lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "143669c5-e2c1-4511-91b3-1ce3d7e385ed"}}}}, {"uuid": "9602fb20-3991-42c9-a5a7-a99c1dea8d9b", "name": "", "x": 38.5754218018766, "y": -122.51914367215898, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a8753d37-07f1-45c6-a483-43cbfb6bf107", "name": "p1rlv13647", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9602fb20-3991-42c9-a5a7-a99c1dea8d9b"}}}}, {"uuid": "5f715d2f-2c1a-4619-96c9-21d42566e2be", "name": "", "x": 38.57580840851501, "y": -122.51892297252556, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c597db56-a6af-472d-a7a2-e331175a2aae", "name": "p1rdm14085", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5f715d2f-2c1a-4619-96c9-21d42566e2be"}}}}, {"uuid": "bba05f6a-3c85-4a4a-81a0-c367140f6a1f", "name": "", "x": 38.57579807527307, "y": -122.51860159809428, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7b712121-d0c2-488a-9224-bea72928796f", "name": "p1rlv13632", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bba05f6a-3c85-4a4a-81a0-c367140f6a1f"}}}}, {"uuid": "df87e52c-507b-4c49-89b5-d67af8264dd1", "name": "", "x": 38.57533041118428, "y": -122.51883432018805, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "180c5680-acd1-4988-ac36-1f351c3f9418", "name": "p1rdm14087", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "df87e52c-507b-4c49-89b5-d67af8264dd1"}}}}, {"uuid": "4395a690-5c9a-46b3-adb7-ac922592d62f", "name": "", "x": 38.57533575960138, "y": -122.51944669646048, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "02f2e50e-d42d-47d1-9274-d840042b64d1", "name": "p1rlv20154", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4395a690-5c9a-46b3-adb7-ac922592d62f"}}}}, {"uuid": "11000b69-6f7e-48dc-859f-2cdd46f95489", "name": "", "x": 38.575287380857716, "y": -122.5193282488865, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "11a125b8-023c-4748-98a9-d74e9e0a7d23", "name": "p1rlv20161", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "11000b69-6f7e-48dc-859f-2cdd46f95489"}}}}, {"uuid": "ee4d4eec-5dfb-4f0b-b0f6-1164bf7d8847", "name": "", "x": 38.58088300114921, "y": -122.50941317390307, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "606673ea-bcd2-459a-a0af-efb8b31c600c", "name": "p1rdt6519lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ee4d4eec-5dfb-4f0b-b0f6-1164bf7d8847"}}}}, {"uuid": "d8ed7224-a9d9-4391-b993-936a9f14dbc6", "name": "", "x": 38.58045459525182, "y": -122.5092825015312, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d4d3fe62-b327-4fc6-b2aa-795c9475019a", "name": "p1rlv13636", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d8ed7224-a9d9-4391-b993-936a9f14dbc6"}}}}, {"uuid": "cc47d065-a18b-4a0d-bbb1-a923026636c1", "name": "", "x": 38.5808931056819, "y": -122.50952733350167, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3e06b069-62f8-40c8-9abc-d4cc83937e41", "name": "p1rdm14090", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc47d065-a18b-4a0d-bbb1-a923026636c1"}}}}, {"uuid": "8316b40c-759e-4de9-82e2-b7599bcc368e", "name": "", "x": 38.58036317851489, "y": -122.5089731408155, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32b75c61-4e97-4e21-a786-8aab7a2d88f8", "name": "p1rlv13678", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8316b40c-759e-4de9-82e2-b7599bcc368e"}}}}, {"uuid": "2b9af43c-355e-4977-af5d-fe2deaa37cb9", "name": "", "x": 38.580046706763056, "y": -122.51235461842337, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "13c02cd3-cff3-4988-95b9-3993b9541427", "name": "p1rdt6520lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2b9af43c-355e-4977-af5d-fe2deaa37cb9"}}}}, {"uuid": "07a6bf40-9c43-494c-a5e0-aedfb16e2e8b", "name": "", "x": 38.580041773656525, "y": -122.51253040494485, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5484eab0-53a8-471c-92ec-29c11c08e740", "name": "p1rlv13639", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "07a6bf40-9c43-494c-a5e0-aedfb16e2e8b"}}}}, {"uuid": "d1a1887e-68b9-4ba7-bb1e-9559ec608ccd", "name": "", "x": 38.5799894527048, "y": -122.51227067031124, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "607d3b54-2cea-476b-afe2-ea40c6c02ddc", "name": "p1rlv13669", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1a1887e-68b9-4ba7-bb1e-9559ec608ccd"}}}}, {"uuid": "0a2e9171-72f9-4d27-851c-45eabbd30ece", "name": "", "x": 38.57993605226405, "y": -122.51243176231385, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "db3abe20-2ffb-4bf8-b425-5613701bd3f2", "name": "p1rdm14092", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a2e9171-72f9-4d27-851c-45eabbd30ece"}}}}, {"uuid": "3e3df82e-7e0f-40fc-aef7-434dfc7f6cd8", "name": "", "x": 38.579872492217575, "y": -122.51231738436074, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2e55b944-ffad-47bf-8348-799afa4c7a1d", "name": "p1rlv13662", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e3df82e-7e0f-40fc-aef7-434dfc7f6cd8"}}}}, {"uuid": "7ede4855-ada0-4ba8-b0c6-2cef3422a414", "name": "", "x": 38.57984627020021, "y": -122.51251273462697, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c0c27b40-83a9-4938-bc12-a2ae57d5eafb", "name": "p1rdm14096", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7ede4855-ada0-4ba8-b0c6-2cef3422a414"}}}}, {"uuid": "88e1daf5-aee2-4047-8cda-6569b0fbeae0", "name": "", "x": 38.57983668465647, "y": -122.51237503029868, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "284bbc5d-bb49-404d-823e-08ec543c90b8", "name": "p1rlv13679", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "88e1daf5-aee2-4047-8cda-6569b0fbeae0"}}}}, {"uuid": "a229c490-a965-4a8a-b3d8-c55d37bf829d", "name": "", "x": 38.57981055069724, "y": -122.51248335572157, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eb3a7829-4233-4af9-9679-08bd114bc00e", "name": "p1rdm14097", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a229c490-a965-4a8a-b3d8-c55d37bf829d"}}}}, {"uuid": "9ccf5d63-0b54-4e31-90f0-2d4a9ce2a633", "name": "", "x": 38.57972969205857, "y": -122.51265129155006, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4f409299-5ac0-4f31-a217-d0aef7fbc4d2", "name": "p1rlv13705", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9ccf5d63-0b54-4e31-90f0-2d4a9ce2a633"}}}}, {"uuid": "8f222518-4a99-4211-9e54-fd4adc5c5032", "name": "", "x": 38.58009749717621, "y": -122.51224697801528, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8a990c6c-4227-4896-8ea6-e92ce5360087", "name": "p1rdm14094", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8f222518-4a99-4211-9e54-fd4adc5c5032"}}}}, {"uuid": "fa7fa1c1-aa2d-4cac-bf81-c50e1d993e77", "name": "", "x": 38.580215414329274, "y": -122.51242987363875, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9467d2d3-ad80-4bc7-aa9f-cd6e76494552", "name": "p1rlv13673", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa7fa1c1-aa2d-4cac-bf81-c50e1d993e77"}}}}, {"uuid": "9bc63553-29f4-4a9a-b99b-5521c3a3c329", "name": "", "x": 38.58029613681535, "y": -122.51233748122965, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c532e298-bdd5-416e-8ebe-a082489ffee6", "name": "p1rlv13675", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9bc63553-29f4-4a9a-b99b-5521c3a3c329"}}}}, {"uuid": "d688086c-831c-45c9-9d48-2f297d145d3d", "name": "", "x": 38.5803966658545, "y": -122.51095681258643, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d0e4e42c-8dcd-47be-bfe8-b8b1eb4a5f24", "name": "p1rdt6521lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d688086c-831c-45c9-9d48-2f297d145d3d"}}}}, {"uuid": "c69b4e5a-4201-42e7-810c-2cf0ebcc7981", "name": "", "x": 38.579486477877886, "y": -122.51051752411439, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ce53d307-fc73-487a-8f6a-3a0e0787bf79", "name": "p1rlv13670", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c69b4e5a-4201-42e7-810c-2cf0ebcc7981"}}}}, {"uuid": "690138af-24c1-49be-867e-6680bd0377bf", "name": "", "x": 38.57976641593619, "y": -122.51065339312383, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1de2ebf2-3207-4bf7-9702-4c729d99a6cf", "name": "p1rlv13694", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "690138af-24c1-49be-867e-6680bd0377bf"}}}}, {"uuid": "1a45c60d-d023-4cae-a611-68068c4a0593", "name": "", "x": 38.579567775011846, "y": -122.51056289521121, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d73963d7-acf4-48b3-8e54-6ee9f403d36f", "name": "p1rlv13695", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1a45c60d-d023-4cae-a611-68068c4a0593"}}}}, {"uuid": "caab1a9d-2a8c-4eed-959a-9039332e3168", "name": "", "x": 38.58050191288654, "y": -122.51070442912985, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c12be3d4-719e-4567-91d9-c0ff24b783f1", "name": "p1rdm14098", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "caab1a9d-2a8c-4eed-959a-9039332e3168"}}}}, {"uuid": "754ba22d-779c-4aa4-b7ce-548fb7f221dc", "name": "", "x": 38.579756732183114, "y": -122.51049272837687, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "479d1486-ed05-44fa-8fab-64035623f267", "name": "p1rlv13642", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "754ba22d-779c-4aa4-b7ce-548fb7f221dc"}}}}, {"uuid": "4d31dd12-f830-474c-9bda-1130c7c4b4f8", "name": "", "x": 38.58037890435985, "y": -122.51109366072052, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1db9a47a-f0ed-4141-b08e-f01a2ffd804f", "name": "p1rdm14100", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d31dd12-f830-474c-9bda-1130c7c4b4f8"}}}}, {"uuid": "8a46299e-61ca-4b07-a11b-4ca253e6e6cf", "name": "", "x": 38.57950522126574, "y": -122.51068960750169, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9a3c050c-cc0d-460e-af02-ce3421431474", "name": "p1rlv13682", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8a46299e-61ca-4b07-a11b-4ca253e6e6cf"}}}}, {"uuid": "c77f9530-ec0a-4054-9a05-006d849ef1ad", "name": "", "x": 38.57973678683187, "y": -122.51254142741766, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "66df2481-ae4f-4f39-aef4-7af09ce1a8fb", "name": "p1rdt6523lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c77f9530-ec0a-4054-9a05-006d849ef1ad"}}}}, {"uuid": "f39c6dd4-71cf-4d64-bcb4-da1faefa9fbc", "name": "", "x": 38.5799209440274, "y": -122.51313219164904, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "43867e2f-79ee-4cec-bed3-0cad0727118c", "name": "p1rlv13649", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f39c6dd4-71cf-4d64-bcb4-da1faefa9fbc"}}}}, {"uuid": "38154626-549f-4873-8768-aab4b840920b", "name": "", "x": 38.58054870314674, "y": -122.51023477359377, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2844042b-3f65-4a8b-8bab-56b42971e6ad", "name": "p1rdm14107", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "38154626-549f-4873-8768-aab4b840920b"}}}}, {"uuid": "28d5033a-494a-4830-857c-27385f72f97e", "name": "", "x": 38.58037752934179, "y": -122.51024741691637, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e8c0a04e-6e22-4da5-9907-7ae8097deb10", "name": "p1rlv13656", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "28d5033a-494a-4830-857c-27385f72f97e"}}}}, {"uuid": "6a791e00-55dc-4756-be50-d51a7faea780", "name": "", "x": 38.58064802372938, "y": -122.51028002263617, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "71c26ca3-0d61-46b8-a95b-710e0b760b62", "name": "p1rlv13690", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a791e00-55dc-4756-be50-d51a7faea780"}}}}, {"uuid": "1307498e-2f33-4f26-9a24-ed1f4799a1a1", "name": "", "x": 38.580549321580946, "y": -122.51038626364308, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0ec2137a-f978-4808-a023-21f13464998b", "name": "p1rdt6524lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1307498e-2f33-4f26-9a24-ed1f4799a1a1"}}}}, {"uuid": "97e975d1-b903-4ebf-b362-88304a9e927a", "name": "", "x": 38.58052253264507, "y": -122.51044160695697, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2256f06d-59e9-4822-987f-7d26f40415c0", "name": "p1rdm14109", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "97e975d1-b903-4ebf-b362-88304a9e927a"}}}}, {"uuid": "980817ce-f98e-4842-9e4e-62861e103709", "name": "", "x": 38.58056754300597, "y": -122.51042982053421, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ecf9ee9-2a3c-431b-84c8-02c7c7aaacb1", "name": "p1rlv13700", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "980817ce-f98e-4842-9e4e-62861e103709"}}}}, {"uuid": "6b9561d7-37ff-4c73-939a-cae0bfc6f012", "name": "", "x": 38.579048350921525, "y": -122.51041447766671, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f8905812-7e3b-4875-87b5-da95999c5bb0", "name": "p1rdt6527lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6b9561d7-37ff-4c73-939a-cae0bfc6f012"}}}}, {"uuid": "171206bc-5e24-403f-8776-7735ef98c781", "name": "", "x": 38.57906268295511, "y": -122.51046524008142, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ef8e6ec-86d3-429c-89b4-6c7260701e70", "name": "p1rlv13661", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "171206bc-5e24-403f-8776-7735ef98c781"}}}}, {"uuid": "29a9d0b7-9834-4fb6-9592-8530158d8ade", "name": "", "x": 38.581032746102906, "y": -122.50929836357719, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d097d9be-dd3a-4616-a873-8ab5013c4e72", "name": "p1rdt6528lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "29a9d0b7-9834-4fb6-9592-8530158d8ade"}}}}, {"uuid": "b43a9112-3dd0-4606-b9e2-b2c280cccd50", "name": "", "x": 38.580921613298514, "y": -122.50890045296518, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d6cdd514-204d-4a86-b0f3-a9bc4990a2aa", "name": "p1rlv13667", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b43a9112-3dd0-4606-b9e2-b2c280cccd50"}}}}, {"uuid": "7b51efa8-65e3-4715-b4c4-3e3fc9865126", "name": "", "x": 38.58083655075754, "y": -122.508633001311, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "850df31b-ee95-4903-93b7-6e5911e8f8a0", "name": "p1rlv13691", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7b51efa8-65e3-4715-b4c4-3e3fc9865126"}}}}, {"uuid": "7124613f-6902-4611-8bf2-0685d7cdd0ca", "name": "", "x": 38.581173273294354, "y": -122.50945964206286, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b51fe8ae-f6d7-48c7-9f84-22fc7c1c1ba9", "name": "p1rdm14115", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7124613f-6902-4611-8bf2-0685d7cdd0ca"}}}}, {"uuid": "f6ed6571-05e2-410b-a5cb-bc043ce84079", "name": "", "x": 38.58081366588884, "y": -122.50894711172428, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6e5db11f-0418-4119-9c71-26619456fd7b", "name": "p1rlv13689", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f6ed6571-05e2-410b-a5cb-bc043ce84079"}}}}, {"uuid": "f1617a39-6b0b-473b-925f-e682bab9adfc", "name": "", "x": 38.57747782265656, "y": -122.51577372256881, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e4ee2d3a-e97c-4ec4-9fa0-d7db1b3e9253", "name": "p1rdt6530lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f1617a39-6b0b-473b-925f-e682bab9adfc"}}}}, {"uuid": "3e778788-41ab-4bac-aa92-c2f1a99a4d9e", "name": "", "x": 38.57719931368139, "y": -122.51529738764073, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ec49353-14d1-4917-83bc-ca62cd94bf30", "name": "p1rlv13684", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e778788-41ab-4bac-aa92-c2f1a99a4d9e"}}}}, {"uuid": "b3fcdf02-4c33-493d-9575-5ea120899df5", "name": "", "x": 38.578752758421444, "y": -122.51042399893916, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bf4a2da0-682a-4119-b398-feaa6f5a8498", "name": "p1rdt6531lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b3fcdf02-4c33-493d-9575-5ea120899df5"}}}}, {"uuid": "dc1038de-320a-4318-bcb0-e653ac19b58f", "name": "", "x": 38.57871154896236, "y": -122.51041164293123, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c5815b75-1226-4221-9bcb-bc75ce85fa17", "name": "p1rlv13693", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dc1038de-320a-4318-bcb0-e653ac19b58f"}}}}, {"uuid": "95a9d089-ce98-467f-8ea9-9b42f507f74f", "name": "", "x": 38.58148963770846, "y": -122.5089654708908, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75c95c35-ea3f-4958-9512-606f78de92b5", "name": "p1rdm14120", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "95a9d089-ce98-467f-8ea9-9b42f507f74f"}}}}, {"uuid": "d03f9226-6e80-4991-b4fc-56e75e294b1f", "name": "", "x": 38.581272297668534, "y": -122.50871436904568, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e60fc98a-9c1d-4975-a9b9-e37271b4ac81", "name": "p1rlv13706", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d03f9226-6e80-4991-b4fc-56e75e294b1f"}}}}, {"uuid": "3c14900e-d03a-4b45-805a-10573b24aa91", "name": "", "x": 38.58157778587544, "y": -122.50884357066717, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c0c3e71a-52a1-49b9-a899-c13d639ac0a6", "name": "p1rdt6532lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3c14900e-d03a-4b45-805a-10573b24aa91"}}}}, {"uuid": "9540f591-cdc2-440a-94fd-1e5f0e14566d", "name": "", "x": 38.581615271240324, "y": -122.50883832397932, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7194199d-e430-4b76-ae77-4c7f51477eed", "name": "p1rdm14121", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9540f591-cdc2-440a-94fd-1e5f0e14566d"}}}}, {"uuid": "fcad0d46-75ae-46e8-b3c1-38c221ef9313", "name": "", "x": 38.5814179357273, "y": -122.50838439741678, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6e396aca-4116-40a0-8f17-bcd41f709ea5", "name": "p1rlv19151", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fcad0d46-75ae-46e8-b3c1-38c221ef9313"}}}}, {"uuid": "e22ae8fc-869d-4fcc-a72c-f32024a9b73d", "name": "", "x": 38.58107483274763, "y": -122.50959807912284, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "10f0e9fa-75b8-4eaa-a2ad-b6a3fb4ae859", "name": "p1rdt6535lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e22ae8fc-869d-4fcc-a72c-f32024a9b73d"}}}}, {"uuid": "0bddd491-bc72-4bbc-94d6-54da98b4518e", "name": "", "x": 38.58061410818166, "y": -122.50863848671041, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d2bfaa34-267c-4dfd-8b6d-4ab444ac4048", "name": "p1rlv13711", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0bddd491-bc72-4bbc-94d6-54da98b4518e"}}}}, {"uuid": "88973f79-5169-4a1b-921d-7cd7c4ba37ab", "name": "", "x": 38.58093200049442, "y": -122.50908714544045, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b93e7299-60a4-49d6-9d34-885860588861", "name": "p1rdt6536lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "88973f79-5169-4a1b-921d-7cd7c4ba37ab"}}}}, {"uuid": "cd358d57-6ede-4102-b78b-91c55b2a32d8", "name": "", "x": 38.58096835695191, "y": -122.50930196751384, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ee766a99-bb6f-4d5c-8513-9d462103f6fc", "name": "p1rlv13713", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cd358d57-6ede-4102-b78b-91c55b2a32d8"}}}}, {"uuid": "3c0b623a-bb42-42e7-96ad-2d9e0d3d3aed", "name": "", "x": 38.58099515130269, "y": -122.50924438048082, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a0f1846b-2515-48ef-9241-0276932f8e75", "name": "p1rlv13723", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3c0b623a-bb42-42e7-96ad-2d9e0d3d3aed"}}}}, {"uuid": "19e3403c-a263-4796-b98b-3831b386ca8d", "name": "", "x": 38.58098269315429, "y": -122.5094004338482, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "57ac4a24-2ddb-46c2-873d-c0b4f3e0600a", "name": "p1rdm14127", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "19e3403c-a263-4796-b98b-3831b386ca8d"}}}}, {"uuid": "d78ff223-7105-40b8-bf1b-61b854c6f63a", "name": "", "x": 38.581152353955275, "y": -122.50952282376217, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cd0effe0-d186-41a8-8197-24144fbc6218", "name": "p1rlv20478", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d78ff223-7105-40b8-bf1b-61b854c6f63a"}}}}, {"uuid": "14987673-7f92-410c-ab47-2773ed46e137", "name": "", "x": 38.575043333110195, "y": -122.51764982578192, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b34f50ff-9a1f-439e-81a8-dfcee658926b", "name": "p1rdt6539lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "14987673-7f92-410c-ab47-2773ed46e137"}}}}, {"uuid": "1276727e-e436-4f80-afa1-9972acfe3f6f", "name": "", "x": 38.57528171570155, "y": -122.51795068214895, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "36019623-eb62-412c-a591-41494980c9b7", "name": "p1rlv13727", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1276727e-e436-4f80-afa1-9972acfe3f6f"}}}}, {"uuid": "016059b9-2ab8-4187-9495-83fc87cb1e18", "name": "", "x": 38.57506491492146, "y": -122.51782585098714, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "006c2753-37b3-4b59-82a6-8ce95f316e26", "name": "p1rlv20450", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "016059b9-2ab8-4187-9495-83fc87cb1e18"}}}}, {"uuid": "51262455-014d-42fc-a2c6-b55e1fecf6c2", "name": "", "x": 38.660324342235185, "y": -122.44998273762167, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "36ab64e0-65cb-4515-9c06-4762a398672a", "name": "p1rdm14185", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "51262455-014d-42fc-a2c6-b55e1fecf6c2"}}}}, {"uuid": "b6bdd6fb-bd85-419a-818b-875257aff1db", "name": "", "x": 38.6601489758078, "y": -122.44970425964786, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "01a18948-75cf-4caf-951f-17a9c8d1f6bc", "name": "p1rlv13784", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b6bdd6fb-bd85-419a-818b-875257aff1db"}}}}, {"uuid": "9f0f8df4-1f7f-44b5-9ff9-a1e84cc3bf9c", "name": "", "x": 38.660528052085354, "y": -122.4498277884296, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4a43920a-a200-40fe-b5b6-3cdba0c7e784", "name": "p1rdt6574lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9f0f8df4-1f7f-44b5-9ff9-a1e84cc3bf9c"}}}}, {"uuid": "1af54902-4345-44cc-8578-75cb2bb7fef3", "name": "", "x": 38.66069273125682, "y": -122.44975004725573, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7f2b4d47-9668-4bcc-933b-1f422f423e3e", "name": "p1rdm14186", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1af54902-4345-44cc-8578-75cb2bb7fef3"}}}}, {"uuid": "c7901057-6ff0-4903-aead-e90a06af9e66", "name": "", "x": 38.66068307092049, "y": -122.44961219759635, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ffd737b-a273-4a6c-91c6-351b5719f658", "name": "p1rlv13812", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c7901057-6ff0-4903-aead-e90a06af9e66"}}}}, {"uuid": "8b51ed47-dfcb-4c2e-ac55-4c15c9ca7323", "name": "", "x": 38.659329203857624, "y": -122.45168740029418, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "608e485b-13ce-493b-be96-ab83ad733c92", "name": "p1rdt6581lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8b51ed47-dfcb-4c2e-ac55-4c15c9ca7323"}}}}, {"uuid": "f950a428-2ee0-42b5-bca3-f9b32c5e4d26", "name": "", "x": 38.66001044613518, "y": -122.45222637580909, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "65052833-aec9-4363-a0cf-4d70fa9bb0ce", "name": "p1rlv13797", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f950a428-2ee0-42b5-bca3-f9b32c5e4d26"}}}}, {"uuid": "44852aa5-fa2c-4502-9c7e-66f3665c8c8e", "name": "", "x": 38.65980253637742, "y": -122.45209003761849, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0aef2ef8-706c-4316-be01-0707ddf0ac7c", "name": "p1rlv13811", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "44852aa5-fa2c-4502-9c7e-66f3665c8c8e"}}}}, {"uuid": "405d3e33-0803-4bab-bab6-03ae336215f7", "name": "", "x": 38.659439276645934, "y": -122.45149514678252, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b8b7c677-d0bf-47d0-8a2a-78417faa49b9", "name": "p1rdm14205", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "405d3e33-0803-4bab-bab6-03ae336215f7"}}}}, {"uuid": "d0122f2a-41cc-4246-90f8-a04abd00afa7", "name": "", "x": 38.660111562159514, "y": -122.45204568307697, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dc5fcb56-435a-4a0d-b442-7489a98ad1cd", "name": "p1rlv13792", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d0122f2a-41cc-4246-90f8-a04abd00afa7"}}}}, {"uuid": "7d3f6c6b-b89e-4239-8ced-0de9f6cea967", "name": "", "x": 38.65993673921714, "y": -122.45188213185789, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c9725b6c-5bac-456a-bb6a-ce16a5e6b1a5", "name": "p1rlv13794", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7d3f6c6b-b89e-4239-8ced-0de9f6cea967"}}}}, {"uuid": "5807dfff-f120-476d-b028-21c8ea93379e", "name": "", "x": 38.66019931022639, "y": -122.45214448227058, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "83d60921-a1f2-4b9c-9709-d2be59b82db5", "name": "p1rlv13805", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5807dfff-f120-476d-b028-21c8ea93379e"}}}}, {"uuid": "762a9906-8f58-46f4-8c29-6a02b47cc88d", "name": "", "x": 38.65918069105062, "y": -122.45208328210967, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "487eef02-df2d-47fe-a20b-ce1c23064495", "name": "p1rdm14210", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "762a9906-8f58-46f4-8c29-6a02b47cc88d"}}}}, {"uuid": "883511c6-7a7d-486b-8068-fcb271ee85b0", "name": "", "x": 38.65967739844402, "y": -122.45230936703297, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "604cb559-0f18-4ef7-8bcd-a07a7e7f96d7", "name": "p1rlv19691", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "883511c6-7a7d-486b-8068-fcb271ee85b0"}}}}, {"uuid": "93ef6245-d527-43bb-bc70-7d08a2b64e0e", "name": "", "x": 38.6320710830909, "y": -122.46441945032754, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e7b9897e-b820-424c-adf8-7416de585357", "name": "p1rdt6847lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "93ef6245-d527-43bb-bc70-7d08a2b64e0e"}}}}, {"uuid": "7ee9b2d7-249f-4fa4-85bc-5e321dccdcdf", "name": "", "x": 38.632085435147204, "y": -122.46447024061165, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "06135bd7-6a77-4f04-a439-4ce8c245447d", "name": "p1rlv14434", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7ee9b2d7-249f-4fa4-85bc-5e321dccdcdf"}}}}, {"uuid": "d54e3cca-aebe-44b5-9000-f52ec82f8845", "name": "", "x": 38.62923340048788, "y": -122.45439823840434, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "94c9fa37-fc5c-4243-b0ca-f70840febaee", "name": "p1rdt6848lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d54e3cca-aebe-44b5-9000-f52ec82f8845"}}}}, {"uuid": "ead318c5-17a0-4d28-9e0b-0029efe1f9ba", "name": "", "x": 38.62920980622029, "y": -122.45452876435519, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d07f5065-df41-484d-8e8a-80b2ff4e0e9b", "name": "p1rlv14435", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ead318c5-17a0-4d28-9e0b-0029efe1f9ba"}}}}, {"uuid": "ef518207-8f21-4771-84fd-ac07da8214a1", "name": "", "x": 38.62930775436262, "y": -122.45427527251405, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ad66e41a-88ab-443e-b10e-9e7b5b899119", "name": "p1rlv14436", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef518207-8f21-4771-84fd-ac07da8214a1"}}}}, {"uuid": "1ee5b07a-7cbd-4569-b1aa-52fb1b80f325", "name": "", "x": 38.648478696952125, "y": -122.39365801344734, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "09a476ff-48a0-4d27-9cf0-c007e2e98acb", "name": "p1rdt6995lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1ee5b07a-7cbd-4569-b1aa-52fb1b80f325"}}}}, {"uuid": "c4dd9eca-e51f-46cd-9b27-abc8d242acdf", "name": "", "x": 38.6484526903026, "y": -122.39361541442939, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c9efa4c9-9832-4aa8-bf44-be0fe1e80cd5", "name": "p1rlv14828", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c4dd9eca-e51f-46cd-9b27-abc8d242acdf"}}}}, {"uuid": "a6befc82-8adc-4a0d-a14e-865e43d77c0a", "name": "", "x": 38.64916844328969, "y": -122.39459452477139, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "536d7c56-85a6-4167-b4f6-2f39936cd662", "name": "p1rdt7015lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a6befc82-8adc-4a0d-a14e-865e43d77c0a"}}}}, {"uuid": "d69748df-ccc3-48ce-9654-18f617d9fb69", "name": "", "x": 38.64918282560407, "y": -122.39464531276182, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d73b0321-e181-4ecd-b431-9aa6985d56d0", "name": "p1rlv14908", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d69748df-ccc3-48ce-9654-18f617d9fb69"}}}}, {"uuid": "8fcb6705-048d-4877-a0bc-e606511d2295", "name": "", "x": 38.56296537249011, "y": -122.50762584426352, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1a371c8b-1993-432c-b2c6-21b18bec27da", "name": "p1rdt7036lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8fcb6705-048d-4877-a0bc-e606511d2295"}}}}, {"uuid": "9037b898-87b5-4754-92ad-23b3c26383e7", "name": "", "x": 38.56302965746093, "y": -122.50745371127641, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3c39b0c-9c92-4934-876f-ee5f542f95cc", "name": "p1rlv14952", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9037b898-87b5-4754-92ad-23b3c26383e7"}}}}, {"uuid": "125c32e8-53ea-4b99-a462-4873a5fbd551", "name": "", "x": 38.562911104383154, "y": -122.50779489358709, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "260ea1f0-7235-47fc-a576-3d647618290e", "name": "p1rdm15468", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "125c32e8-53ea-4b99-a462-4873a5fbd551"}}}}, {"uuid": "dfd993e3-9f3d-4b0c-bd6a-abd0bcfed918", "name": "", "x": 38.56269409956021, "y": -122.50762420325977, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "19231152-1fd1-4e07-a5d9-603c765b2cae", "name": "p1rlv15008", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dfd993e3-9f3d-4b0c-bd6a-abd0bcfed918"}}}}, {"uuid": "adac6dc8-8be6-48fb-949a-6b94d12f7d4b", "name": "", "x": 38.56256229551184, "y": -122.50269706817427, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "046f6c53-8d9c-43a1-88ce-169ade9e9557", "name": "p1rdt7038lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "adac6dc8-8be6-48fb-949a-6b94d12f7d4b"}}}}, {"uuid": "8ca7ccc6-e0d8-4b03-856f-60ac9d14b366", "name": "", "x": 38.562607012632625, "y": -122.50261641391278, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a9e128f5-eb18-44df-8ec4-35bd049ef630", "name": "p1rlv14954", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8ca7ccc6-e0d8-4b03-856f-60ac9d14b366"}}}}, {"uuid": "e911b985-e79e-4f2c-93b3-ef325ec3ea1e", "name": "", "x": 38.56228530015727, "y": -122.50538482056976, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cd6a9808-9889-4f16-825d-c9763357c293", "name": "p1rdt7046lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e911b985-e79e-4f2c-93b3-ef325ec3ea1e"}}}}, {"uuid": "859e95c6-17e7-4a0d-9a9d-6892808b6de9", "name": "", "x": 38.56236063103573, "y": -122.50548009684834, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "884ff47e-8e20-4ae8-97bd-287d0ca9dc1b", "name": "p1rlv14974", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "859e95c6-17e7-4a0d-9a9d-6892808b6de9"}}}}, {"uuid": "971c2a17-55d8-4d9f-9371-a6f61aafe5a7", "name": "", "x": 38.558417547967906, "y": -122.507932804306, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf93e681-3ab6-4929-95f1-1da6d5dd28fa", "name": "p1rdt7054lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "971c2a17-55d8-4d9f-9371-a6f61aafe5a7"}}}}, {"uuid": "08d23886-0c5d-44c8-b2ad-7ea381317beb", "name": "", "x": 38.55834318385272, "y": -122.50806707079614, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f4f8b1bc-83c3-4819-9d98-9491df98d494", "name": "p1rlv14992", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "08d23886-0c5d-44c8-b2ad-7ea381317beb"}}}}, {"uuid": "2b6a7bde-a0c4-449f-8fe4-d8400882bf90", "name": "", "x": 38.55812685464717, "y": -122.50805706795369, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a914ec3a-4883-42a7-b25d-133a1410b8d9", "name": "p1rlv15056", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2b6a7bde-a0c4-449f-8fe4-d8400882bf90"}}}}, {"uuid": "5e15ee0b-3693-41ac-8cb0-055c517b69d7", "name": "", "x": 38.558469106593094, "y": -122.50800882572935, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25a6c92d-ea7f-4ede-af16-713ceedfc7b0", "name": "p1rdm15533", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5e15ee0b-3693-41ac-8cb0-055c517b69d7"}}}}, {"uuid": "356f834c-0b74-448a-bb21-123afc00d12d", "name": "", "x": 38.558289451182375, "y": -122.50814777833953, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2182c9fd-fd3d-4cb1-b525-192480823e2f", "name": "p1rlv15046", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "356f834c-0b74-448a-bb21-123afc00d12d"}}}}, {"uuid": "1aaf2a4d-ff03-454e-a713-9582309fa5ce", "name": "", "x": 38.559657411750145, "y": -122.50277093263843, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bc33ade7-4471-40b8-8e9b-1846e0ad60e8", "name": "p1rdt7061lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1aaf2a4d-ff03-454e-a713-9582309fa5ce"}}}}, {"uuid": "637627d3-e56a-4bc8-9ff8-1a6c5760087b", "name": "", "x": 38.55937583329394, "y": -122.50291811146595, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cc29de5b-3a3f-40c0-bde4-9a57f5f62b5c", "name": "p1rlv15007", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "637627d3-e56a-4bc8-9ff8-1a6c5760087b"}}}}, {"uuid": "2c405f7c-6e09-4705-a315-e45355677bb1", "name": "", "x": 38.563364746370645, "y": -122.50424505524006, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f4445ca5-2fed-4352-ab78-66e072a4f482", "name": "p1rdm15583", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2c405f7c-6e09-4705-a315-e45355677bb1"}}}}, {"uuid": "55ebc70c-c0d4-4a17-bcc7-8a77aee0e74b", "name": "", "x": 38.56324735128747, "y": -122.50418847116366, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "07e3b847-cc9a-4f84-bc00-cb4396b6dea0", "name": "p1rlv15027", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "55ebc70c-c0d4-4a17-bcc7-8a77aee0e74b"}}}}, {"uuid": "c5817b8f-ea88-454f-88ee-92b03f9a1ddf", "name": "", "x": 38.56307400876931, "y": -122.50435786467884, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1ff878e1-3143-4f8e-aa92-74d0a9046417", "name": "p1rdt7067lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c5817b8f-ea88-454f-88ee-92b03f9a1ddf"}}}}, {"uuid": "a34ca3d2-08f9-4046-8516-8323c5dbc0bb", "name": "", "x": 38.562913772741126, "y": -122.50415632890832, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5ad4c131-0be7-46e5-8a32-5ff92552dfe6", "name": "p1rdm15584", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a34ca3d2-08f9-4046-8516-8323c5dbc0bb"}}}}, {"uuid": "e8c80a4b-9086-4dc3-828c-6661b91adb34", "name": "", "x": 38.563057133200985, "y": -122.50396021637685, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "80a74c6f-c9ec-4742-8fce-ad73c0a6c459", "name": "p1rlv15197", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e8c80a4b-9086-4dc3-828c-6661b91adb34"}}}}, {"uuid": "63c74f01-b8e6-49bc-8ad2-88e28191cae0", "name": "", "x": 38.559099227598956, "y": -122.50637076262426, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9a1566f1-7f0d-41d7-adad-425c9a344eb0", "name": "p1rdt7069lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "63c74f01-b8e6-49bc-8ad2-88e28191cae0"}}}}, {"uuid": "12d42c56-9b80-4486-a359-8e37f81f809d", "name": "", "x": 38.558729158203484, "y": -122.50556236696406, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "baccbdab-efc0-487d-b00d-38d3d4be57b4", "name": "p1rlv15045", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "12d42c56-9b80-4486-a359-8e37f81f809d"}}}}, {"uuid": "56999ec8-df70-47e8-a22e-684768da3d2c", "name": "", "x": 38.56237327512186, "y": -122.49906112727943, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "844bdc22-2e32-43ee-8e0b-26f3f4c107b8", "name": "p1rdt7070lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "56999ec8-df70-47e8-a22e-684768da3d2c"}}}}, {"uuid": "e3bc0fa3-6811-498e-a16c-8320d0a293f7", "name": "", "x": 38.5623473065519, "y": -122.49901854030558, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "366c9c98-59f1-46d5-b39c-4046703e5e4b", "name": "p1rlv15064", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e3bc0fa3-6811-498e-a16c-8320d0a293f7"}}}}, {"uuid": "a83cc9c4-4b11-4010-aa19-b53e73508459", "name": "", "x": 38.56125382119533, "y": -122.50733957591181, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0e0577c2-8275-4303-ad11-2c4f56df3f5c", "name": "p1rdt7075lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a83cc9c4-4b11-4010-aa19-b53e73508459"}}}}, {"uuid": "9a93678c-2745-43ef-87e0-0b312f04dcc6", "name": "", "x": 38.56131680649824, "y": -122.50731619031008, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a56b9ad8-c53b-4652-bf94-a7a7dfb8b306", "name": "p1rlv15082", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9a93678c-2745-43ef-87e0-0b312f04dcc6"}}}}, {"uuid": "5c7c788f-e292-4ed5-b8b6-2d92179a1549", "name": "", "x": 38.561391603460336, "y": -122.50795843776592, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d86bd7f-7759-4d74-9c74-d58010498f92", "name": "p1rdt7080lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5c7c788f-e292-4ed5-b8b6-2d92179a1549"}}}}, {"uuid": "67d11589-d890-4924-88d4-c67f869a6f93", "name": "", "x": 38.561343164924004, "y": -122.50782854332392, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "161d4e7b-30f2-447c-a369-1bfa3ba2cd70", "name": "p1rlv15109", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "67d11589-d890-4924-88d4-c67f869a6f93"}}}}, {"uuid": "95c151ef-ad3e-4f24-a147-4c639e3a18d2", "name": "", "x": 38.56161341947106, "y": -122.5078037444857, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bb6d8f13-f04e-4b80-a8dc-e16af1dc860e", "name": "p1rlv15125", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "95c151ef-ad3e-4f24-a147-4c639e3a18d2"}}}}, {"uuid": "4b3c05ad-cedd-477b-93ed-febea5d5232f", "name": "", "x": 38.559858339047835, "y": -122.50687058401597, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d0c96fe-78c2-4303-ac5c-bbe440f19666", "name": "p1rdt7087lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4b3c05ad-cedd-477b-93ed-febea5d5232f"}}}}, {"uuid": "db357bf8-bd4f-49eb-b3b1-04933eed13f3", "name": "", "x": 38.56006676468359, "y": -122.5064714121144, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bdee6d84-9253-4fba-b713-3e41d706e999", "name": "p1rlv15163", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "db357bf8-bd4f-49eb-b3b1-04933eed13f3"}}}}, {"uuid": "7c2faef8-a10d-4e28-bc4d-8542fee740d0", "name": "", "x": 38.55723982473556, "y": -122.5059256790796, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0f1652e8-6cf7-43d4-8474-e61a74873675", "name": "p1rdt7088lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7c2faef8-a10d-4e28-bc4d-8542fee740d0"}}}}, {"uuid": "5715e666-b8a9-484f-ba5f-8126a94010c7", "name": "", "x": 38.55722600645399, "y": -122.50597665691777, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2d2f8fcb-c279-49d5-88be-39e6a1d1990b", "name": "p1rlv15170", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5715e666-b8a9-484f-ba5f-8126a94010c7"}}}}, {"uuid": "0b91e779-c081-46eb-ba57-0400b5966cb1", "name": "", "x": 38.55763186186392, "y": -122.50515401038457, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "73cfcce9-a925-4f29-9cde-6dd6f50735e1", "name": "p1rdt7089lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0b91e779-c081-46eb-ba57-0400b5966cb1"}}}}, {"uuid": "7645a840-49f1-4f3d-bf88-0d557ff10242", "name": "", "x": 38.5576058954936, "y": -122.50511142397353, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dc7cd505-823c-49bb-9e49-3681267dbef0", "name": "p1rlv15171", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7645a840-49f1-4f3d-bf88-0d557ff10242"}}}}, {"uuid": "1846601f-ea73-4a6d-b41f-f06723617295", "name": "", "x": 38.55819291339373, "y": -122.50729514639205, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5d6a4c80-d261-4350-8224-8fe5191459c7", "name": "p1rdt7090lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1846601f-ea73-4a6d-b41f-f06723617295"}}}}, {"uuid": "5f1f5eaa-fca2-4063-8623-d2c87240ac98", "name": "", "x": 38.558186799297566, "y": -122.50731063399988, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e218b01d-f713-4baf-9688-7e77ea413c8c", "name": "p1rlv15180", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5f1f5eaa-fca2-4063-8623-d2c87240ac98"}}}}, {"uuid": "d41eed58-eb05-4eb6-91b8-26ead7b42739", "name": "", "x": 38.643254518897194, "y": -122.45483995487372, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6718b871-3967-4c29-83e5-441799c7fb92", "name": "p1rdt7201lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d41eed58-eb05-4eb6-91b8-26ead7b42739"}}}}, {"uuid": "b9bae9e3-62cb-4c3b-a8b7-2fdb6158be87", "name": "", "x": 38.64314352984028, "y": -122.45483682254313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fd21ae8b-7841-43b4-871f-316c4b8b4cd2", "name": "p1rlv15394", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b9bae9e3-62cb-4c3b-a8b7-2fdb6158be87"}}}}, {"uuid": "8c6660ec-b375-4cc2-8f0d-b4269bbad1e5", "name": "", "x": 38.64359496143701, "y": -122.45501725670924, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5ec1f313-f341-498c-b1c2-6669b1cbc629", "name": "p1rlv15399", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8c6660ec-b375-4cc2-8f0d-b4269bbad1e5"}}}}, {"uuid": "862f0625-04be-4c1c-9407-0449f1b4e76d", "name": "", "x": 38.643369459814934, "y": -122.45497300119509, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8bc46399-0276-4ae7-aa8b-4cdd3d3555e8", "name": "p1rlv15419", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "862f0625-04be-4c1c-9407-0449f1b4e76d"}}}}, {"uuid": "6d0c0017-941d-496d-a360-3f767288ac7d", "name": "", "x": 38.643190246717545, "y": -122.45519268460242, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "335df4da-50d2-4fbe-a271-ac04257d35c7", "name": "p1rlv15478", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6d0c0017-941d-496d-a360-3f767288ac7d"}}}}, {"uuid": "f9f10379-c1aa-4451-908d-38eecfa2b445", "name": "", "x": 38.6429090279938, "y": -122.45418759719459, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "37ccfa64-1373-49b2-85f6-279abea3c945", "name": "p1rlv15523", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f9f10379-c1aa-4451-908d-38eecfa2b445"}}}}, {"uuid": "f75bd794-6d16-46ee-99bd-adaf4993874e", "name": "", "x": 38.64844611776415, "y": -122.46453889053006, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5d5e45d6-867a-4442-8258-2c04891dbc4b", "name": "p1rdt7220lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f75bd794-6d16-46ee-99bd-adaf4993874e"}}}}, {"uuid": "16ccf6c7-32c1-4714-b004-edbd0fcf2460", "name": "", "x": 38.64842013673824, "y": -122.46449626559803, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f9ca373a-b1c3-464d-bbe3-c05b728beb30", "name": "p1rlv15418", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "16ccf6c7-32c1-4714-b004-edbd0fcf2460"}}}}, {"uuid": "6226913c-7d7d-477d-95e9-54bb8abd2648", "name": "", "x": 38.64544505846416, "y": -122.42121162161781, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d6a6156f-e72a-41f0-a307-e6030de24fde", "name": "p1rdt7224lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6226913c-7d7d-477d-95e9-54bb8abd2648"}}}}, {"uuid": "27cb7911-2e9b-464c-93c0-ac632f6ff630", "name": "", "x": 38.64521777279914, "y": -122.42138184387917, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "921f8f54-ff83-4d2f-8bf4-ee80bab64ce8", "name": "p1rlv15487", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "27cb7911-2e9b-464c-93c0-ac632f6ff630"}}}}, {"uuid": "69b27ea4-60b0-4eda-81a3-4486c128089b", "name": "", "x": 38.64535123894055, "y": -122.42103603545684, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "79c5341b-3cd2-41a3-8bbf-e50857b00dae", "name": "p1rdm15891", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "69b27ea4-60b0-4eda-81a3-4486c128089b"}}}}, {"uuid": "09527da2-781f-41bf-b313-d35ece88a326", "name": "", "x": 38.64513570345144, "y": -122.42118715458822, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "26009a7e-9bfc-4967-af28-4d8937539eb1", "name": "p1rlv15423", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "09527da2-781f-41bf-b313-d35ece88a326"}}}}, {"uuid": "bb839b26-b6d1-4449-a1b9-452e490d2a89", "name": "", "x": 38.64529779575312, "y": -122.42116286827518, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "34e0ffc2-da17-441b-bd4d-26d5a1104712", "name": "p1rlv15474", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bb839b26-b6d1-4449-a1b9-452e490d2a89"}}}}, {"uuid": "a328fc38-9751-4e00-9895-2603399f0135", "name": "", "x": 38.648428944357136, "y": -122.46102923499245, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2087cee5-9f6e-4400-8ca8-bbb120cd4dae", "name": "p1rdt7248lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a328fc38-9751-4e00-9895-2603399f0135"}}}}, {"uuid": "750db3fa-bb1a-4d04-b712-ff839caf5bfb", "name": "", "x": 38.64843531677844, "y": -122.46107118044478, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "544be417-0db6-45a7-8314-ec40944781fa", "name": "p1rlv15466", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "750db3fa-bb1a-4d04-b712-ff839caf5bfb"}}}}, {"uuid": "862f5d4c-08c7-48f1-a229-70ced1db006d", "name": "", "x": 38.648497708978724, "y": -122.4609213210892, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3c4e3eac-0b1a-4feb-b39f-079c6d2c1d82", "name": "p1rlv15483", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "862f5d4c-08c7-48f1-a229-70ced1db006d"}}}}, {"uuid": "32bfc63e-f0fa-4281-8265-4295041aa664", "name": "", "x": 38.64803011681224, "y": -122.46114316554923, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6579cc93-2b08-4010-816d-3bef509000cd", "name": "p1rlv15488", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "32bfc63e-f0fa-4281-8265-4295041aa664"}}}}, {"uuid": "6a9646be-d91a-42e6-b44c-c57056f16ac4", "name": "", "x": 38.64867815080695, "y": -122.46096593584461, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b09822b3-a220-48ff-ad4f-62fca602f8b6", "name": "p1rlv15542", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a9646be-d91a-42e6-b44c-c57056f16ac4"}}}}, {"uuid": "009068dc-1050-4ede-85b3-38c88606ebaa", "name": "", "x": 38.64806971694897, "y": -122.4591176468453, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b4f7df4-5453-459d-8599-48fd5f29a9c6", "name": "p1rdt7253lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "009068dc-1050-4ede-85b3-38c88606ebaa"}}}}, {"uuid": "4f4045d5-a424-4828-8712-a5e2d27af07c", "name": "", "x": 38.6480437339618, "y": -122.45907502411583, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6749066f-4739-41ec-8369-8da49dd9e1c8", "name": "p1rlv15484", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4f4045d5-a424-4828-8712-a5e2d27af07c"}}}}, {"uuid": "ce488c5f-6b15-495e-a1dc-3e08aea6376a", "name": "", "x": 38.650849807011845, "y": -122.4260111114199, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1130272e-b98e-496f-aeb9-c094cf9cd824", "name": "p1rdt7268lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ce488c5f-6b15-495e-a1dc-3e08aea6376a"}}}}, {"uuid": "6a086fd3-e4a3-4194-82d1-3d55ac26d4a6", "name": "", "x": 38.650823812052785, "y": -122.42596849916298, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6eec860d-08cf-4690-93e6-d909429d363d", "name": "p1rlv15525", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a086fd3-e4a3-4194-82d1-3d55ac26d4a6"}}}}, {"uuid": "654a9de7-dcb0-4746-8171-280e65546dae", "name": "", "x": 38.56642393843708, "y": -122.500066081999, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d304e5e0-2cc1-4167-9fad-6fc72228d828", "name": "p1rdt7298lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "654a9de7-dcb0-4746-8171-280e65546dae"}}}}, {"uuid": "6a642350-2238-4a5c-825f-8e833548e191", "name": "", "x": 38.56639797023211, "y": -122.50002349228465, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "688da57a-6f10-4ef8-8763-202a88c3a495", "name": "p1rlv15603", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a642350-2238-4a5c-825f-8e833548e191"}}}}, {"uuid": "81704916-b78c-4299-8fc1-4958e3705545", "name": "", "x": 38.586910904171326, "y": -122.52012069769289, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "43df4c14-a198-4d51-87f4-80000198cd47", "name": "p1rdt7301lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "81704916-b78c-4299-8fc1-4958e3705545"}}}}, {"uuid": "9fcd0830-ea92-460e-88c4-2f39c88f4ed7", "name": "", "x": 38.58688494322849, "y": -122.52007808865979, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c32ce070-e690-4fc1-92ac-f857691de578", "name": "p1rlv15606", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9fcd0830-ea92-460e-88c4-2f39c88f4ed7"}}}}, {"uuid": "a00d66f5-e5d7-4a85-b1e2-41d52b447303", "name": "", "x": 38.56306853879527, "y": -122.5102770561152, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3e2a141f-436a-45c0-9c15-179301a439c8", "name": "p1rdt7302lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a00d66f5-e5d7-4a85-b1e2-41d52b447303"}}}}, {"uuid": "aa80928f-e27e-42d3-ab52-19e97aa61d61", "name": "", "x": 38.56308491307865, "y": -122.51055992850522, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32291502-d7be-4b45-8af7-cb217448e73f", "name": "p1rlv15607", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aa80928f-e27e-42d3-ab52-19e97aa61d61"}}}}, {"uuid": "cd52fc3f-b014-47cf-820c-b191189ba802", "name": "", "x": 38.563191661348114, "y": -122.51022633928095, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2715a637-d6f0-4e7b-b43e-20836bf4e614", "name": "p1rlv15638", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cd52fc3f-b014-47cf-820c-b191189ba802"}}}}, {"uuid": "62d95444-7296-4d3a-8cb0-3fa5dd858b1b", "name": "", "x": 38.56290700610434, "y": -122.51179679741092, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0926064a-1c87-450a-b282-23708de8aec4", "name": "p1rdt7306lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "62d95444-7296-4d3a-8cb0-3fa5dd858b1b"}}}}, {"uuid": "bf198d6d-a6e0-4737-a4e7-8a2939338d8d", "name": "", "x": 38.56368313784799, "y": -122.511382300603, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5ab2d6dc-f5bb-4320-86f3-bf08bb7cf93f", "name": "p1rlv15614", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bf198d6d-a6e0-4737-a4e7-8a2939338d8d"}}}}, {"uuid": "5fea1be8-832e-410d-af35-560129d549bc", "name": "", "x": 38.57387166576081, "y": -122.5068092396372, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6ce9dd2c-9e17-46b7-a6f4-e85077664432", "name": "p1rdt7307lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5fea1be8-832e-410d-af35-560129d549bc"}}}}, {"uuid": "e984cc18-d43d-4279-98ad-7a297ad808c9", "name": "", "x": 38.573802276520816, "y": -122.50677924408086, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6106bbe7-7a47-4c50-8b2a-d46d7432bccf", "name": "p1rlv15617", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e984cc18-d43d-4279-98ad-7a297ad808c9"}}}}, {"uuid": "60d115bb-a2f5-47fd-ad21-f774776aafdc", "name": "", "x": 38.573945931269776, "y": -122.50665198381543, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0bb184ad-cb26-4317-8c40-f2c8a9f80dab", "name": "p1rlv19146", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "60d115bb-a2f5-47fd-ad21-f774776aafdc"}}}}, {"uuid": "6243e000-7c2a-4199-aba2-ca01fe1b1dd7", "name": "", "x": 38.57392039558398, "y": -122.50700803276428, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "546433b3-d70e-49ed-9037-ec88adda79b9", "name": "p1rlv19147", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6243e000-7c2a-4199-aba2-ca01fe1b1dd7"}}}}, {"uuid": "1df6c2be-0b95-47ed-8ccf-650263d8acdb", "name": "", "x": 38.563303651285544, "y": -122.5126284769322, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e2d6046b-9ece-4295-a180-41bf2ce47ce6", "name": "p1rdt7311lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1df6c2be-0b95-47ed-8ccf-650263d8acdb"}}}}, {"uuid": "daba764b-a0fc-4c47-b9d1-f41023553bb6", "name": "", "x": 38.56384855592281, "y": -122.51215022095688, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1151b559-3ae0-4863-9363-9b395bbfc403", "name": "p1rlv15622", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "daba764b-a0fc-4c47-b9d1-f41023553bb6"}}}}, {"uuid": "1f14723b-86dc-4a46-a672-3ed1ff4b6072", "name": "", "x": 38.56815134225955, "y": -122.50546068410047, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "97844fdb-b016-4ca3-8777-b0553ead9297", "name": "p1rdt7314lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1f14723b-86dc-4a46-a672-3ed1ff4b6072"}}}}, {"uuid": "ea07bd82-2337-41b7-ac6c-4158f09b55a2", "name": "", "x": 38.56817687324023, "y": -122.50541766691859, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ec0bca53-a58b-4004-8dba-8defca9db4c7", "name": "p1rlv15629", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea07bd82-2337-41b7-ac6c-4158f09b55a2"}}}}, {"uuid": "502ec234-aaf7-4749-8910-9336c0c13d45", "name": "", "x": 38.56855471658057, "y": -122.50523980787194, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "22b1ecce-d5df-4f42-abb2-9f4c3d3a28c5", "name": "p1rdt7318lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "502ec234-aaf7-4749-8910-9336c0c13d45"}}}}, {"uuid": "7ae0df86-6d12-44d0-9fd4-967a2abacbfa", "name": "", "x": 38.568569050828, "y": -122.50529056187261, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a5af6dae-d20f-4a31-9544-b9455cd639bd", "name": "p1rlv15634", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7ae0df86-6d12-44d0-9fd4-967a2abacbfa"}}}}, {"uuid": "c125e674-85b7-4f60-93b0-24e4722e6cc3", "name": "", "x": 38.60115277629168, "y": -122.46102699453549, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "58be5cbe-5a7c-4fa5-972d-e03100b3bb46", "name": "p1rdt7550lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c125e674-85b7-4f60-93b0-24e4722e6cc3"}}}}, {"uuid": "d96464bf-d57f-4a79-95ab-73e600c00eb4", "name": "", "x": 38.60105048076314, "y": -122.46095488399553, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5984e209-9f0e-4844-91e6-902c8329f13c", "name": "p1rlv16114", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d96464bf-d57f-4a79-95ab-73e600c00eb4"}}}}, {"uuid": "f04f0ccb-57e8-461b-80fb-4acde4ab77df", "name": "", "x": 38.60120431220644, "y": -122.46109154303083, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "807b0bef-0d34-44a9-a2a9-0c0a11f4ea8e", "name": "p1rlv16178", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f04f0ccb-57e8-461b-80fb-4acde4ab77df"}}}}, {"uuid": "6b7c2c76-7774-48ee-910e-81eb26d11585", "name": "", "x": 38.60318695205525, "y": -122.45853113684389, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1c4d7ee3-fc5d-4a17-a717-3d6b6d5a67ae", "name": "p1rdt7551lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6b7c2c76-7774-48ee-910e-81eb26d11585"}}}}, {"uuid": "6cf6c48f-0c39-4e82-aaa5-9850a4ea3d6c", "name": "", "x": 38.6034004318743, "y": -122.45853704613184, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "52d1b79d-5c6b-4b44-9998-600c6debd999", "name": "p1rlv16115", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6cf6c48f-0c39-4e82-aaa5-9850a4ea3d6c"}}}}, {"uuid": "ce389c53-ae3e-4477-bd2e-926434e7d3c2", "name": "", "x": 38.60293177722496, "y": -122.45852908328547, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6efff4f7-c67b-4cfb-a72d-30b6616825b1", "name": "p1rlv16157", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ce389c53-ae3e-4477-bd2e-926434e7d3c2"}}}}, {"uuid": "86be8abe-cfa1-408c-9fae-445d6897801f", "name": "", "x": 38.601851120199065, "y": -122.45542100224573, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1f5d6708-cef4-4aac-9fa0-c738953c788f", "name": "p1rdt7552lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "86be8abe-cfa1-408c-9fae-445d6897801f"}}}}, {"uuid": "7d645f59-ab39-476e-b903-ae66856dfb97", "name": "", "x": 38.60199783561238, "y": -122.45535495885304, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "972f8088-b67b-47d0-a86f-49179dfb1c92", "name": "p1rlv16116", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7d645f59-ab39-476e-b903-ae66856dfb97"}}}}, {"uuid": "5306fedc-377c-405e-8294-70ab141da9c9", "name": "", "x": 38.60173719494335, "y": -122.45550622371668, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "92a37082-36d4-4eca-95e4-88dbcacd6db5", "name": "p1rlv16197", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5306fedc-377c-405e-8294-70ab141da9c9"}}}}, {"uuid": "2f0e73df-0c62-40a8-a734-286365ac0370", "name": "", "x": 38.60639320900444, "y": -122.45582291610495, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e7a672b2-d127-4fb5-8cc4-8115b8ef3f60", "name": "p1rdt7553lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2f0e73df-0c62-40a8-a734-286365ac0370"}}}}, {"uuid": "9c579c2e-db54-4d6b-906e-b3e3396c2a73", "name": "", "x": 38.606405183855294, "y": -122.45547094869913, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "204899ec-81e4-4a72-bf70-69b3428a49a1", "name": "p1rlv16117", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9c579c2e-db54-4d6b-906e-b3e3396c2a73"}}}}, {"uuid": "2bf36cf3-92b0-4202-afe5-e4a82e38ea10", "name": "", "x": 38.60746648825486, "y": -122.45829224306911, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "86a6d184-d883-4e27-aee5-b89c82163284", "name": "p1rdt7554lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2bf36cf3-92b0-4202-afe5-e4a82e38ea10"}}}}, {"uuid": "2df0eb30-a882-4def-ab77-29e11f4fd85d", "name": "", "x": 38.60753796176142, "y": -122.45877011077201, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bca0b3a0-d4cb-4a4a-9b14-aa23d9e5e5fe", "name": "p1rlv16118", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2df0eb30-a882-4def-ab77-29e11f4fd85d"}}}}, {"uuid": "c4771003-2c0d-47fc-bf08-901d4c211e51", "name": "", "x": 38.60761943761314, "y": -122.45884989486198, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c840cf3f-be15-448b-8c03-8942c586b135", "name": "p1rlv16139", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c4771003-2c0d-47fc-bf08-901d4c211e51"}}}}, {"uuid": "14b6738b-41dd-4f20-ab31-7fd70218af0b", "name": "", "x": 38.60732511225313, "y": -122.45756577239354, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "68aa5cc5-f6bf-4417-8653-747c56b37b5e", "name": "p1rlv16201", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "14b6738b-41dd-4f20-ab31-7fd70218af0b"}}}}, {"uuid": "0b85b1e3-d355-43b8-8b7a-6468a77acd10", "name": "", "x": 38.60729988695483, "y": -122.45795645616205, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf413742-18c8-483d-b8f1-f125f95323da", "name": "p1rlv16209", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0b85b1e3-d355-43b8-8b7a-6468a77acd10"}}}}, {"uuid": "988e9a2d-9ed8-4c63-b121-042df9ce3188", "name": "", "x": 38.599910107670105, "y": -122.4605115694972, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0de9c581-b78b-44d6-8693-59b995e2a3bb", "name": "p1rdt7555lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "988e9a2d-9ed8-4c63-b121-042df9ce3188"}}}}, {"uuid": "53064509-7052-4af7-87fe-e13f6ad6d921", "name": "", "x": 38.60005645544839, "y": -122.46036515331646, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c0d6e608-d5bf-40d6-9efd-f3b0922e7d77", "name": "p1rlv16119", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "53064509-7052-4af7-87fe-e13f6ad6d921"}}}}, {"uuid": "7829fac3-fe6e-4708-aebe-204569ca6f84", "name": "", "x": 38.607794956621454, "y": -122.45548336703727, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0b593ec6-e1e3-48c2-b352-f7966f206aa9", "name": "p1rdt7559lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7829fac3-fe6e-4708-aebe-204569ca6f84"}}}}, {"uuid": "84d7a033-8e7b-4fb0-9cc0-c8644b232b05", "name": "", "x": 38.60770977446864, "y": -122.45501316679001, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6da4b2d0-66c7-43fb-9aab-3bbac03aa989", "name": "p1rlv16124", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "84d7a033-8e7b-4fb0-9cc0-c8644b232b05"}}}}, {"uuid": "cb0b839a-cd6f-491d-932b-83f7ff4c8736", "name": "", "x": 38.60025024332015, "y": -122.46073516079042, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "05e30abd-3c40-4dbd-9261-ca8a8abd9c56", "name": "p1rdt7561lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb0b839a-cd6f-491d-932b-83f7ff4c8736"}}}}, {"uuid": "e788a403-3ee0-4bc1-83e8-447ea9a8a20a", "name": "", "x": 38.60030209684127, "y": -122.46086860989422, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bd41f55a-4b5d-4c19-9787-801072b3b946", "name": "p1rlv16126", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e788a403-3ee0-4bc1-83e8-447ea9a8a20a"}}}}, {"uuid": "4124fd29-4733-49fc-a471-b50ad153de68", "name": "", "x": 38.60042704179853, "y": -122.46060354272663, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "102b9460-ea9a-4099-b16f-40b8fdf99ef7", "name": "p1rlv16133", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4124fd29-4733-49fc-a471-b50ad153de68"}}}}, {"uuid": "0d6f3592-9121-45e3-9cbe-84457185ba70", "name": "", "x": 38.60180967142113, "y": -122.46424249788332, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f7588b3b-f54c-483d-b354-b9908483019a", "name": "p1rdt7564lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0d6f3592-9121-45e3-9cbe-84457185ba70"}}}}, {"uuid": "8dec918d-10ab-432a-b8bb-e415a12f101b", "name": "", "x": 38.60183518685866, "y": -122.46419944605898, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "676de1a3-2dfd-4faa-a057-7739e825d136", "name": "p1rlv16135", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8dec918d-10ab-432a-b8bb-e415a12f101b"}}}}, {"uuid": "31d60c7f-e3f0-4686-8e19-b56bd4e1464a", "name": "", "x": 38.6078075576706, "y": -122.45772713266135, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f2b3b9e1-3d98-44c1-bd38-9325623a1553", "name": "p1rdt7570lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "31d60c7f-e3f0-4686-8e19-b56bd4e1464a"}}}}, {"uuid": "fa7474fe-414e-4687-8d13-9b47b7f5bf2e", "name": "", "x": 38.60779838775444, "y": -122.45777980644779, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6d21c357-1033-45e1-84a0-b82ceafe6ab8", "name": "p1rlv16146", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa7474fe-414e-4687-8d13-9b47b7f5bf2e"}}}}, {"uuid": "14c8ea02-6b8a-4683-a209-b207e62df26b", "name": "", "x": 38.60626762047214, "y": -122.45581795786703, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "69bf048e-54cd-4e41-a23e-485b0cd98fae", "name": "p1rdt7572lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "14c8ea02-6b8a-4683-a209-b207e62df26b"}}}}, {"uuid": "2814eb4a-ef43-4726-81b5-35cb10bb963a", "name": "", "x": 38.60645647275145, "y": -122.45487334223284, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b15792ca-a6bd-47e5-8c67-5c3076174848", "name": "p1rlv16149", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2814eb4a-ef43-4726-81b5-35cb10bb963a"}}}}, {"uuid": "84a70399-13e1-4ea7-b2cd-5a587410bf53", "name": "", "x": 38.60650078143132, "y": -122.45471221720932, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1aacea55-115d-46c3-9590-725cf5040f38", "name": "p1rlv16200", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "84a70399-13e1-4ea7-b2cd-5a587410bf53"}}}}, {"uuid": "644491c8-32e3-415d-a8b2-9cdc7acd7dfa", "name": "", "x": 38.606181337381166, "y": -122.4557827336667, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33a848c7-076e-4025-863b-ce9151bcc3ac", "name": "p1rdm16630", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "644491c8-32e3-415d-a8b2-9cdc7acd7dfa"}}}}, {"uuid": "1cd42c9f-87d5-443d-bc3d-baf635075a0e", "name": "", "x": 38.60633132723502, "y": -122.45509250327417, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b85e180a-8eb4-4acc-a816-d99758cc16ea", "name": "p1rlv16158", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1cd42c9f-87d5-443d-bc3d-baf635075a0e"}}}}, {"uuid": "756f2ab1-9338-45a3-9e5c-bf0de418e671", "name": "", "x": 38.60650742609989, "y": -122.45740736442846, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a742708-0f8b-42d0-a977-b5ce5e36a042", "name": "p1rdt7574lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "756f2ab1-9338-45a3-9e5c-bf0de418e671"}}}}, {"uuid": "b72df13b-b760-4f9c-8e84-7384a4026df1", "name": "", "x": 38.606502198240534, "y": -122.45735394894129, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "74edd9e9-24a5-4b36-8ca8-24ef2fa3e972", "name": "p1rlv16156", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b72df13b-b760-4f9c-8e84-7384a4026df1"}}}}, {"uuid": "bd429532-7ff5-4e19-8118-d02b72b2445d", "name": "", "x": 38.59916576086806, "y": -122.46399319639457, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "56b05024-7907-458d-a5c3-0e54ffbabdb5", "name": "p1rdt7576lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bd429532-7ff5-4e19-8118-d02b72b2445d"}}}}, {"uuid": "7198a865-1cfe-44a8-8fab-751b1cc8a6af", "name": "", "x": 38.59972953494432, "y": -122.46374387036614, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4fb5abb7-dd79-49aa-9185-88a90bb45bc7", "name": "p1rlv16168", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7198a865-1cfe-44a8-8fab-751b1cc8a6af"}}}}, {"uuid": "89474c6b-5738-4943-9265-a4fb35b3a0a5", "name": "", "x": 38.603712525417045, "y": -122.46283870922412, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4d00b7fe-0384-4c12-a0cf-8895458d3b80", "name": "p1rdt7579lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "89474c6b-5738-4943-9265-a4fb35b3a0a5"}}}}, {"uuid": "332633b6-3eb5-4d54-8439-cfecf21faba5", "name": "", "x": 38.60368654376888, "y": -122.46279611119927, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cbbe8401-53a1-4ce7-9ce1-02f547055d95", "name": "p1rlv16177", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "332633b6-3eb5-4d54-8439-cfecf21faba5"}}}}, {"uuid": "e75397fa-6344-480e-8b24-b7e3fb47e90b", "name": "", "x": 38.601513560330964, "y": -122.46255652294417, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "abc940b0-c9f5-4582-adaf-ad7f4a79a35f", "name": "p1rdt7588lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e75397fa-6344-480e-8b24-b7e3fb47e90b"}}}}, {"uuid": "1dbfb486-355e-48bb-9547-1c5af9aab2e8", "name": "", "x": 38.601499761325734, "y": -122.46260754027634, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0ca42395-8d67-4e83-80ec-159cacb490f8", "name": "p1rlv16206", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1dbfb486-355e-48bb-9547-1c5af9aab2e8"}}}}, {"uuid": "f01e60a2-6edb-4fa2-90ef-fa24804682ad", "name": "", "x": 38.63266298601826, "y": -122.4216856102529, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "53e9cf92-1c91-428f-bdff-64257257ad5b", "name": "p1rdt7589lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f01e60a2-6edb-4fa2-90ef-fa24804682ad"}}}}, {"uuid": "4e04d8fd-20ec-4f89-8bbf-cf16549031aa", "name": "", "x": 38.632738611285475, "y": -122.42182684518295, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9fd05f3c-df77-45bc-8686-458b681a3d08", "name": "p1rlv16210", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4e04d8fd-20ec-4f89-8bbf-cf16549031aa"}}}}, {"uuid": "6dea6e95-aba5-4fce-b04c-34f7c28df0ab", "name": "", "x": 38.63262911078122, "y": -122.4215519854009, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "56b91b3f-dfdd-41bf-9d2e-a8183077c752", "name": "p1rlv16235", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6dea6e95-aba5-4fce-b04c-34f7c28df0ab"}}}}, {"uuid": "226e95df-79cb-49c6-99eb-7ce9f9be1eda", "name": "", "x": 38.63109043622211, "y": -122.42673165565434, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ff1e0d26-d845-43c3-9aaf-01d1c007b9a1", "name": "p1rdt7598lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "226e95df-79cb-49c6-99eb-7ce9f9be1eda"}}}}, {"uuid": "a34d4271-e724-4b08-9a1e-9e75013aa774", "name": "", "x": 38.631104804579536, "y": -122.42678243753235, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b9761003-33fa-482a-967b-b508ab67c19f", "name": "p1rlv16221", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a34d4271-e724-4b08-9a1e-9e75013aa774"}}}}, {"uuid": "7115795f-d38c-435c-bd32-d79fd0c3e2be", "name": "", "x": 38.59926349646212, "y": -122.48320976110043, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d838502-3769-4d70-839b-26fd628ce478", "name": "p1rdt7599lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7115795f-d38c-435c-bd32-d79fd0c3e2be"}}}}, {"uuid": "c3f465b9-0d5a-4166-b70d-0b31c3a84cab", "name": "", "x": 38.59924968840877, "y": -122.4832607729825, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4809afc1-2d3d-491d-80e5-9cd4e8da08f2", "name": "p1rlv16222", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c3f465b9-0d5a-4166-b70d-0b31c3a84cab"}}}}, {"uuid": "7e356edd-9a1e-4a20-b1e2-05ff729a0ab9", "name": "", "x": 38.63045512607571, "y": -122.42581761149648, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d3488ff0-696f-4180-bc70-41ff37f9c365", "name": "p1rdt7605lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7e356edd-9a1e-4a20-b1e2-05ff729a0ab9"}}}}, {"uuid": "dba9df17-dbb7-40e0-8389-32f86a83d0ce", "name": "", "x": 38.63042913104939, "y": -122.4257750112935, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b8767650-39c5-4d4a-80ce-af408c246599", "name": "p1rlv16228", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dba9df17-dbb7-40e0-8389-32f86a83d0ce"}}}}, {"uuid": "ba3209f3-ddc3-42d2-9fb6-73352cdcc890", "name": "", "x": 38.62802329409922, "y": -122.420609783299, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0fdfea70-187a-4bbc-ba3f-69cb74c4d5c5", "name": "p1rdt7612lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ba3209f3-ddc3-42d2-9fb6-73352cdcc890"}}}}, {"uuid": "f517027f-3138-4efe-b5c1-6b209dd16b66", "name": "", "x": 38.62799729719169, "y": -122.42056718642846, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9642fa30-e5f7-42f1-8fda-ab75a265d25a", "name": "p1rlv16239", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f517027f-3138-4efe-b5c1-6b209dd16b66"}}}}, {"uuid": "eae6de67-8927-41f1-b2b4-566cb14958c4", "name": "", "x": 38.56073046128886, "y": -122.50852889395006, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "269e9ba5-bc54-4cbd-9140-4b1bea74fc53", "name": "p1rdt7615lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eae6de67-8927-41f1-b2b4-566cb14958c4"}}}}, {"uuid": "dfa27b4c-8f60-4a6f-8e32-e240e90c01fa", "name": "", "x": 38.56046440447144, "y": -122.50887900476087, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e82036d9-e6c8-42c3-b45b-30bef6902bbc", "name": "p1rlv16242", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dfa27b4c-8f60-4a6f-8e32-e240e90c01fa"}}}}, {"uuid": "6ee0bd86-1680-444a-a29c-1dc0ca96d7f2", "name": "", "x": 38.56073966572795, "y": -122.50857474214654, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "978533ca-ef57-4cb6-9e7f-b3c6d1bbd7d5", "name": "p1rlv16261", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6ee0bd86-1680-444a-a29c-1dc0ca96d7f2"}}}}, {"uuid": "47348236-35ea-4e14-9db4-04f53ff4cb88", "name": "", "x": 38.562034810135316, "y": -122.51158858609705, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "65458dd3-50e0-48d3-a0db-0015707d3cea", "name": "p1rdm16694", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "47348236-35ea-4e14-9db4-04f53ff4cb88"}}}}, {"uuid": "51f24211-6a02-4069-9407-7162a0e828bf", "name": "", "x": 38.56202613361287, "y": -122.51166899029859, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "268549c6-0c8b-44ac-b933-316b36645366", "name": "p1rlv16253", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "51f24211-6a02-4069-9407-7162a0e828bf"}}}}, {"uuid": "84b11cd9-6ad0-4a24-a958-715b6fc7be35", "name": "", "x": 38.56186788179104, "y": -122.51113810898512, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6af13868-ecb1-4110-be3f-537741287035", "name": "p1rdt7616lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "84b11cd9-6ad0-4a24-a958-715b6fc7be35"}}}}, {"uuid": "7d5808cb-7939-481a-8de5-91a65946aa43", "name": "", "x": 38.56181598959075, "y": -122.51098173878029, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "83d31d7a-8900-4f2e-9183-8a10f07e2bdd", "name": "p1rdm16695", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7d5808cb-7939-481a-8de5-91a65946aa43"}}}}, {"uuid": "9e3cb4e1-00a3-40b7-a310-e1d3288381c9", "name": "", "x": 38.561797870283755, "y": -122.51095890578438, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c620d4b9-a849-4bf6-b108-118836866602", "name": "p1rlv16270", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9e3cb4e1-00a3-40b7-a310-e1d3288381c9"}}}}, {"uuid": "301d7474-7394-4adb-83c5-de8da079d030", "name": "", "x": 38.56163474835187, "y": -122.51074193179929, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "766647d4-7c3c-4058-b30c-dbc593b88ecb", "name": "p1rdm16693", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "301d7474-7394-4adb-83c5-de8da079d030"}}}}, {"uuid": "ee0e3777-b5c5-4c55-8a82-0a2aa0ec819c", "name": "", "x": 38.56165286770099, "y": -122.51076476468909, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "20818cc7-617e-4ab7-8f7c-31eea6496a02", "name": "p1rlv16243", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ee0e3777-b5c5-4c55-8a82-0a2aa0ec819c"}}}}, {"uuid": "effa99d5-0528-4214-9f65-c85da4d99cb0", "name": "", "x": 38.563138374369146, "y": -122.50973711139406, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4be4af94-fee7-40d6-9061-9a0fe0e7377e", "name": "p1rdt7617lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "effa99d5-0528-4214-9f65-c85da4d99cb0"}}}}, {"uuid": "daf01f10-6d6c-445b-9fdd-f5006c1c211b", "name": "", "x": 38.56309099533974, "y": -122.50985972349204, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e0164339-acc1-4b95-aa31-3af42cf943f7", "name": "p1rlv16244", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "daf01f10-6d6c-445b-9fdd-f5006c1c211b"}}}}, {"uuid": "53d2cce6-a3d7-4ce1-b40e-37e98b714398", "name": "", "x": 38.563135188623946, "y": -122.50965281749981, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4d1fb8eb-57aa-4366-afe5-b79174f3a4c7", "name": "p1rdm16697", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "53d2cce6-a3d7-4ce1-b40e-37e98b714398"}}}}, {"uuid": "767e8d01-6f03-4aab-bbdd-e7516fac9674", "name": "", "x": 38.563267563002256, "y": -122.50965942729142, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "04647fad-19dc-4ed8-8820-aa312674145c", "name": "p1rlv16255", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "767e8d01-6f03-4aab-bbdd-e7516fac9674"}}}}, {"uuid": "e6e642bd-5a02-4bab-9654-a8d16102dcd4", "name": "", "x": 38.64626899154278, "y": -122.41892573953396, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "795f4296-7c54-4e96-8468-52903af39708", "name": "p1rdm16699", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e6e642bd-5a02-4bab-9654-a8d16102dcd4"}}}}, {"uuid": "75f5fcc1-c81f-49ae-a4c9-1fe46bb70e41", "name": "", "x": 38.64646884092825, "y": -122.4192458831601, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5c6a5f39-0654-4e73-8050-c6c4ad9d54e6", "name": "p1rlv16252", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "75f5fcc1-c81f-49ae-a4c9-1fe46bb70e41"}}}}, {"uuid": "86e7ee95-7549-4c76-908c-030d93ec9795", "name": "", "x": 38.64614340209092, "y": -122.41904166679946, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "acb015a8-a9f8-492b-ab3f-b107bd956f91", "name": "p1rdm16698", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "86e7ee95-7549-4c76-908c-030d93ec9795"}}}}, {"uuid": "cb0a2f85-7a50-463d-bb48-789ac1c19a51", "name": "", "x": 38.646106728547146, "y": -122.41891555875277, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3783c838-b72e-42cd-8b0b-3005bca3cf5e", "name": "p1rlv16245", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb0a2f85-7a50-463d-bb48-789ac1c19a51"}}}}, {"uuid": "4a2288ec-9b7d-4dba-b1ba-c617235fedd4", "name": "", "x": 38.64641551310019, "y": -122.41882510751344, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "49f37435-54fc-42b4-baba-94f0611c8c76", "name": "p1rdt7618lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4a2288ec-9b7d-4dba-b1ba-c617235fedd4"}}}}, {"uuid": "25ca9092-333a-4071-952e-beb0df30161f", "name": "", "x": 38.64677146238617, "y": -122.41848500827774, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "73030a97-0574-4802-80d1-14fefeafa63a", "name": "p1rdm16700", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "25ca9092-333a-4071-952e-beb0df30161f"}}}}, {"uuid": "7a39814a-94fc-4129-9a0b-165f7813be33", "name": "", "x": 38.64669874248704, "y": -122.41835919083687, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "19aeb510-ac0e-4279-8db0-8de282beccc8", "name": "p1rlv16267", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7a39814a-94fc-4129-9a0b-165f7813be33"}}}}, {"uuid": "0630d605-bb3f-43f0-b776-d4ada20f11aa", "name": "", "x": 38.56141189302572, "y": -122.50849775727877, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3a205379-48f9-444c-baf8-dc84fc9c6d8a", "name": "p1rdt7619lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0630d605-bb3f-43f0-b776-d4ada20f11aa"}}}}, {"uuid": "15292442-11f0-4f4b-8858-9f1431a817b7", "name": "", "x": 38.561113439797154, "y": -122.50892049903847, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dd2dc2db-787a-4732-bae4-01186082a92d", "name": "p1rlv16246", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "15292442-11f0-4f4b-8858-9f1431a817b7"}}}}, {"uuid": "7388c6fa-ce1e-47ab-a43a-73bf44b2dacd", "name": "", "x": 38.56276173762939, "y": -122.51370313533468, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9af91c50-929d-4ac6-9272-7c44d17a0094", "name": "p1rdt7620lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7388c6fa-ce1e-47ab-a43a-73bf44b2dacd"}}}}, {"uuid": "90982ae6-16f2-483c-944a-57039dcebb07", "name": "", "x": 38.56259236273701, "y": -122.5134672071745, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a8d5e9b7-dc95-41f9-8547-99d5e2eba874", "name": "p1rlv16247", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "90982ae6-16f2-483c-944a-57039dcebb07"}}}}, {"uuid": "5106ecc5-1a2f-41bc-b6c8-3ae15176b9e9", "name": "", "x": 38.56176044882826, "y": -122.50995307443512, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60f0bddf-6e4b-495c-a98d-f3940d69a5e9", "name": "p1rdt7621lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5106ecc5-1a2f-41bc-b6c8-3ae15176b9e9"}}}}, {"uuid": "97ebfd06-ca63-41d2-ae54-9e9c8da085a2", "name": "", "x": 38.561693460357375, "y": -122.50969704739022, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "feb24768-feab-40f0-acc3-0b2bb500133a", "name": "p1rlv16248", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "97ebfd06-ca63-41d2-ae54-9e9c8da085a2"}}}}, {"uuid": "5ced85f7-f461-4760-989d-da3f0b33b912", "name": "", "x": 38.63755744615242, "y": -122.465948154899, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e2075fb-9691-447e-9a73-f88649310bc1", "name": "p1rdt7624lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ced85f7-f461-4760-989d-da3f0b33b912"}}}}, {"uuid": "5bc50684-7a0d-436b-972b-fe999f8f51db", "name": "", "x": 38.63754827273094, "y": -122.46600084949326, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32a9302f-2d40-4c2a-bde9-e4039694fed7", "name": "p1rlv16256", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5bc50684-7a0d-436b-972b-fe999f8f51db"}}}}, {"uuid": "cbff86f3-b1ca-4bb9-b929-b7706ddb1140", "name": "", "x": 38.56312481406225, "y": -122.50942641108807, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a6b1e3b6-ce3a-4ad6-a046-6608530b2ec2", "name": "p1rdt7625lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cbff86f3-b1ca-4bb9-b929-b7706ddb1140"}}}}, {"uuid": "ca85a7fc-d2bf-4ae4-bde9-edd5d0c42655", "name": "", "x": 38.56379044489856, "y": -122.50902854183389, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "935c99a6-bef6-4417-872c-0685011c440c", "name": "p1rlv16257", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ca85a7fc-d2bf-4ae4-bde9-edd5d0c42655"}}}}, {"uuid": "9094241e-f572-4ca2-a2f7-73618f62dfb3", "name": "", "x": 38.5622508740622, "y": -122.51221444287553, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "56f8eed1-77ae-4d65-80aa-7ae148350333", "name": "p1rdt7626lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9094241e-f572-4ca2-a2f7-73618f62dfb3"}}}}, {"uuid": "40f7128c-ed34-4a06-8927-100507e5ed27", "name": "", "x": 38.562245476566225, "y": -122.51240209551142, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fdf35585-e2b3-4463-a6a8-acb352f25003", "name": "p1rlv16260", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "40f7128c-ed34-4a06-8927-100507e5ed27"}}}}, {"uuid": "6de641fa-7013-4aa1-9223-c0f5bcdcc02b", "name": "", "x": 38.56232619942912, "y": -122.51230972629801, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fc746539-662a-4fe4-8774-6ba2dc538118", "name": "p1rlv16269", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6de641fa-7013-4aa1-9223-c0f5bcdcc02b"}}}}, {"uuid": "00cd9384-7f49-423e-b329-029dcc4041a7", "name": "", "x": 38.56258212321864, "y": -122.51385355991457, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "90d8891c-6e6d-46b9-8f88-acc9453c6541", "name": "p1rdt7627lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "00cd9384-7f49-423e-b329-029dcc4041a7"}}}}, {"uuid": "124e10ea-1bf0-41b7-a040-a7913288ddea", "name": "", "x": 38.562602805051284, "y": -122.51381147731462, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2797febc-f5e7-4cb3-b26f-ace990dc6920", "name": "p1rlv16262", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "124e10ea-1bf0-41b7-a040-a7913288ddea"}}}}, {"uuid": "e8a8f728-47d8-4295-b6f3-42e071ca524f", "name": "", "x": 38.56133819555369, "y": -122.51026584276248, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ad2599f-313b-49c6-abaa-19177e1a9edc", "name": "p1rdt7630lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e8a8f728-47d8-4295-b6f3-42e071ca524f"}}}}, {"uuid": "6fb5ec76-7803-4c02-9ae4-bb649280dfc2", "name": "", "x": 38.56092456814972, "y": -122.50968682475795, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e8835446-b333-4be9-96bd-57ff9d01ebd3", "name": "p1rlv16266", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6fb5ec76-7803-4c02-9ae4-bb649280dfc2"}}}}, {"uuid": "86853692-b205-4618-a7a5-8176c8cb9876", "name": "", "x": 38.5616967364387, "y": -122.50900438404291, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4861056b-b634-4900-94bb-d6c995387351", "name": "p1rdt7631lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "86853692-b205-4618-a7a5-8176c8cb9876"}}}}, {"uuid": "eb7a2999-86c8-4f6f-a010-1615b513d664", "name": "", "x": 38.561466725079015, "y": -122.50935425276774, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ba6ebe7f-b6b9-4f89-8bbf-7bffd63e10ef", "name": "p1rlv16268", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eb7a2999-86c8-4f6f-a010-1615b513d664"}}}}, {"uuid": "3398e448-e018-40e6-a50b-4504d0b77a7b", "name": "", "x": 38.637592171075106, "y": -122.45349611008078, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bfa76dc8-4007-4e52-9692-2eec7cb574e0", "name": "p1rdt7699lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3398e448-e018-40e6-a50b-4504d0b77a7b"}}}}, {"uuid": "dcb8b703-4cb4-4039-9993-9d9b04402c41", "name": "", "x": 38.63759072492407, "y": -122.45258089846875, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f58421d6-268b-417f-a579-c9c51d010697", "name": "p1rlv16416", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dcb8b703-4cb4-4039-9993-9d9b04402c41"}}}}, {"uuid": "1e841da1-29f5-41d4-8ba5-c88ecf63ee18", "name": "", "x": 38.63777525230912, "y": -122.45349869276687, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e60bfe9e-d2fa-4576-87f3-0a866b88d07d", "name": "p1rdm16862", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1e841da1-29f5-41d4-8ba5-c88ecf63ee18"}}}}, {"uuid": "37827724-bd74-4a74-8d3f-92058b8bebf4", "name": "", "x": 38.63771801473168, "y": -122.45282121950886, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9d908890-4fe4-4349-92de-464c4165b185", "name": "p1rlv16395", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "37827724-bd74-4a74-8d3f-92058b8bebf4"}}}}, {"uuid": "8e7d6de1-f6ed-4806-9ef0-24d1d6dbbf11", "name": "", "x": 38.636816322579385, "y": -122.45331816430568, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0cc95d09-c799-488e-81e8-50326a7da1ea", "name": "p1rdt7701lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8e7d6de1-f6ed-4806-9ef0-24d1d6dbbf11"}}}}, {"uuid": "db27e2bb-978f-4758-9ed3-644b0176ec4d", "name": "", "x": 38.63714867725408, "y": -122.45248085191842, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "323373a9-8e7d-4fb4-8970-dcc0e6d26c98", "name": "p1rlv16397", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "db27e2bb-978f-4758-9ed3-644b0176ec4d"}}}}, {"uuid": "5762879f-fed8-408b-b69c-2693dac42fd6", "name": "", "x": 38.634315239366806, "y": -122.45108169056164, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8ef392d6-b408-4a7f-8a67-9fe43e1df582", "name": "p1rdt7704lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5762879f-fed8-408b-b69c-2693dac42fd6"}}}}, {"uuid": "dbfb266a-0b63-477e-8649-ac94dbb2b196", "name": "", "x": 38.63384513963928, "y": -122.45197349911196, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "571a4c92-95b6-4bc0-a25d-0d9239a41a89", "name": "p1rlv20070", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dbfb266a-0b63-477e-8649-ac94dbb2b196"}}}}, {"uuid": "0e217484-8e6b-4d4d-af52-4413a7a594c3", "name": "", "x": 38.634430184568174, "y": -122.45121471447422, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0797f1d0-3499-4f88-a749-fc576240f791", "name": "p1rdm16872", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0e217484-8e6b-4d4d-af52-4413a7a594c3"}}}}, {"uuid": "fa4839ee-ecfc-4d14-8f46-c4b0651ff87c", "name": "", "x": 38.63430515491296, "y": -122.45145694554178, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eeb598c2-f0b9-44df-bfaa-be66e4dc3920", "name": "p1rlv16401", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa4839ee-ecfc-4d14-8f46-c4b0651ff87c"}}}}, {"uuid": "a9f961bd-cefe-4dae-ab39-0e189f5bff80", "name": "", "x": 38.63414958801971, "y": -122.4509525977873, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c5e00667-6368-49d3-a5dd-c574c79dba21", "name": "p1rdm16873", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a9f961bd-cefe-4dae-ab39-0e189f5bff80"}}}}, {"uuid": "1481206c-4e04-432b-a9f1-67ab90498892", "name": "", "x": 38.63394415582507, "y": -122.45134480308546, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d0b689f0-d4b1-4419-bff8-f72436625c60", "name": "p1rlv20068", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1481206c-4e04-432b-a9f1-67ab90498892"}}}}, {"uuid": "e97df275-6dc5-479d-a4d3-e0c412bde049", "name": "", "x": 38.633795319458095, "y": -122.45167161174345, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3f0e3c74-2d63-4612-b0e5-d986ebee0086", "name": "p1rlv20069", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e97df275-6dc5-479d-a4d3-e0c412bde049"}}}}, {"uuid": "a1266fd6-c0ee-49b8-82fc-cc6fce9a2e1b", "name": "", "x": 38.63640935476333, "y": -122.45301103214067, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "59a62487-c709-428e-9e97-c7c285a1305c", "name": "p1rdt7712lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a1266fd6-c0ee-49b8-82fc-cc6fce9a2e1b"}}}}, {"uuid": "5ad66ee7-9785-4523-a2f9-c52cd5d0b5a8", "name": "", "x": 38.636725727850084, "y": -122.45261045736181, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "99f97a6b-4e94-4a35-ad00-12e7004ab5e3", "name": "p1rlv16412", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ad66ee7-9785-4523-a2f9-c52cd5d0b5a8"}}}}, {"uuid": "3d37469f-053d-4c17-a339-a46fa2bfeb6a", "name": "", "x": 38.634298404574224, "y": -122.452544518945, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f6d10a4e-e7bc-4448-bca3-a5f2117b6198", "name": "p1rdt7718lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3d37469f-053d-4c17-a339-a46fa2bfeb6a"}}}}, {"uuid": "74a7237e-d8c7-411c-83b2-d4013f798b7a", "name": "", "x": 38.63419311757913, "y": -122.45254929248175, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f367b63c-c4cb-4810-a270-8bd0153b7b32", "name": "p1rlv16422", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "74a7237e-d8c7-411c-83b2-d4013f798b7a"}}}}, {"uuid": "4bac0a18-2477-438a-94a0-812507fc8fcd", "name": "", "x": 38.634445386111494, "y": -122.4525358843223, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c2242f1c-542f-4c1f-b3e6-19482cccde8d", "name": "p1rlv16424", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4bac0a18-2477-438a-94a0-812507fc8fcd"}}}}, {"uuid": "0a20861b-7864-4182-b71d-404098b80998", "name": "", "x": 38.65497278403905, "y": -122.46523250990784, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "96dcd934-01a0-4719-89bc-a18430edf179", "name": "p1rdt7735lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a20861b-7864-4182-b71d-404098b80998"}}}}, {"uuid": "fe1bfd41-fe22-4cbe-ab09-2fa1f2f47f5a", "name": "", "x": 38.65486042898651, "y": -122.46493056100381, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8e090544-3c8e-4716-9dae-0b311a1017ea", "name": "p1rlv16445", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fe1bfd41-fe22-4cbe-ab09-2fa1f2f47f5a"}}}}, {"uuid": "63c6b927-d3dc-4646-aec2-7061f58953c5", "name": "", "x": 38.653199252282036, "y": -122.46489297492766, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5ed564b5-8d49-4ff7-94c2-b245981472e8", "name": "p1rdt7790lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "63c6b927-d3dc-4646-aec2-7061f58953c5"}}}}, {"uuid": "98406b17-db64-435a-89ca-371b67b5b8e4", "name": "", "x": 38.65291599440307, "y": -122.46539322901351, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "53d578d8-8492-471b-8f66-233e489a3652", "name": "p1rlv16570", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "98406b17-db64-435a-89ca-371b67b5b8e4"}}}}, {"uuid": "38850062-35c5-42c4-8473-53df10d67257", "name": "", "x": 38.62241982511306, "y": -122.43971932407153, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b9dd5bb5-1410-4635-8a85-d23d7c3e55ad", "name": "p1rdt7954lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "38850062-35c5-42c4-8473-53df10d67257"}}}}, {"uuid": "40b7450c-e6b0-4a78-af62-e7c24b136327", "name": "", "x": 38.62265588015955, "y": -122.43879451092451, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7578563f-d4b3-423b-a8f5-3ee91a042d19", "name": "p1rlv16905", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "40b7450c-e6b0-4a78-af62-e7c24b136327"}}}}, {"uuid": "36950be0-4fd3-451a-9fac-8409812f4199", "name": "", "x": 38.622543574694504, "y": -122.43980628940227, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e982887d-97c6-4af5-b536-a15a372b3379", "name": "p1rdm17416", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "36950be0-4fd3-451a-9fac-8409812f4199"}}}}, {"uuid": "f39b6cba-092a-4569-9a47-5b35d3249d8e", "name": "", "x": 38.62287193593768, "y": -122.43874687668992, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4faf40b9-9ade-45b5-ade8-3f1833605cd1", "name": "p1rlv16882", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f39b6cba-092a-4569-9a47-5b35d3249d8e"}}}}, {"uuid": "967a9ca5-e96e-430d-84d9-5cdc3b729f49", "name": "", "x": 38.62281759636039, "y": -122.43998044342054, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3a96167-4b09-49c9-baf7-4fb588ecb002", "name": "p1rdt7973lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "967a9ca5-e96e-430d-84d9-5cdc3b729f49"}}}}, {"uuid": "756b813f-44fd-4a19-ba1d-6f9e311b850f", "name": "", "x": 38.623145420142684, "y": -122.43939954007212, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c2308dc3-d10b-4049-862d-caf3356fa9a7", "name": "p1rlv16912", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "756b813f-44fd-4a19-ba1d-6f9e311b850f"}}}}, {"uuid": "edeba34e-bd5b-47af-bada-d48b971f09c9", "name": "", "x": 38.62309085570953, "y": -122.43929657626467, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "11a633b0-2b09-4c66-94d4-d1c24cdd9cf5", "name": "p1rlv16988", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "edeba34e-bd5b-47af-bada-d48b971f09c9"}}}}, {"uuid": "29f78aa6-2219-41f0-b8fd-73cfb14343d6", "name": "", "x": 38.622914421161234, "y": -122.44009059423414, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "53ed549a-9c24-4bdd-9e40-aee5308d8120", "name": "p1rdm17505", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "29f78aa6-2219-41f0-b8fd-73cfb14343d6"}}}}, {"uuid": "b591bafa-ff50-4f54-a8fb-5aca6caab3c9", "name": "", "x": 38.62313800426249, "y": -122.43973273911827, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4c570ef7-c483-4c1e-b0fd-8712e8e9a7cd", "name": "p1rlv16904", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b591bafa-ff50-4f54-a8fb-5aca6caab3c9"}}}}, {"uuid": "b8e4d113-43ab-498e-ba02-2cda8df4a829", "name": "", "x": 38.618288153419634, "y": -122.43508780454101, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cb63be48-94ec-4c9f-9991-77892e14171b", "name": "p1rdt7983lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b8e4d113-43ab-498e-ba02-2cda8df4a829"}}}}, {"uuid": "786f1d10-0412-4963-9e25-0d1e156451c2", "name": "", "x": 38.6178110723834, "y": -122.43578826842699, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "07e01053-37f3-4b9f-a9f1-d51bccd29803", "name": "p1rlv16919", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "786f1d10-0412-4963-9e25-0d1e156451c2"}}}}, {"uuid": "ecbeb3c5-deaf-40f8-b0f7-c5efa49d8122", "name": "", "x": 38.617981016890134, "y": -122.43552274050253, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dfa28657-cd8e-4700-a189-83e021f77bee", "name": "p1rlv17033", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ecbeb3c5-deaf-40f8-b0f7-c5efa49d8122"}}}}, {"uuid": "9b9c7472-9dea-4ebe-8b54-92c0d3484b0a", "name": "", "x": 38.60009989462982, "y": -122.45165246954828, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "415fe6e9-953e-40f6-8ae8-43834e4e6ce4", "name": "p1rdt7986lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9b9c7472-9dea-4ebe-8b54-92c0d3484b0a"}}}}, {"uuid": "ae9eb3b3-537f-40c2-943f-3469e0711386", "name": "", "x": 38.60019584777296, "y": -122.45157886471317, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ce315d98-1556-429b-aebb-0c868892396a", "name": "p1rlv16922", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ae9eb3b3-537f-40c2-943f-3469e0711386"}}}}, {"uuid": "e1274621-2f83-4c64-9c96-f50c8d474a6c", "name": "", "x": 38.5999461596242, "y": -122.45214347781915, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7dff1455-5154-429f-a33f-044d8501281d", "name": "p1rlv16957", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e1274621-2f83-4c64-9c96-f50c8d474a6c"}}}}, {"uuid": "85b83e09-ec12-486f-ad2e-0555a1ba557f", "name": "", "x": 38.60009505177635, "y": -122.45122362894173, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "19130741-0fe1-4a12-8a55-96355609bccb", "name": "p1rlv17063", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "85b83e09-ec12-486f-ad2e-0555a1ba557f"}}}}, {"uuid": "6897a9e4-802b-4dc9-a6ca-c8eca130dd9c", "name": "", "x": 38.61708288860949, "y": -122.43744053773406, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "94f12107-697c-4278-95e0-32b6eb49fdb3", "name": "p1rdt7988lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6897a9e4-802b-4dc9-a6ca-c8eca130dd9c"}}}}, {"uuid": "999335b2-ae36-40cb-9fd3-b2738191bb3d", "name": "", "x": 38.61700772395571, "y": -122.43739120644287, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ba1d053-4462-4eb4-aca6-5ede38aa283c", "name": "p1rlv16926", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "999335b2-ae36-40cb-9fd3-b2738191bb3d"}}}}, {"uuid": "52cf2f27-de63-46c8-92e2-0e220ca503d5", "name": "", "x": 38.6171461348718, "y": -122.43747450374505, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5439f343-8176-4d92-99d4-bb9209817f6b", "name": "p1rlv17106", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "52cf2f27-de63-46c8-92e2-0e220ca503d5"}}}}, {"uuid": "f1373852-4d12-4fab-86ca-a37b50a04f22", "name": "", "x": 38.62030446603571, "y": -122.4376486590166, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f5b22c57-7912-4e9f-9b06-6a8ff706a58d", "name": "p1rdt8012lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f1373852-4d12-4fab-86ca-a37b50a04f22"}}}}, {"uuid": "0a779003-8296-47e1-b30a-ece8f8025987", "name": "", "x": 38.619635701851216, "y": -122.43854235774572, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "57e8aa34-3967-4f22-a978-cb513c49c153", "name": "p1rlv16992", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a779003-8296-47e1-b30a-ece8f8025987"}}}}, {"uuid": "3b30dab7-8ea2-4d20-afae-2bb1a6efded1", "name": "", "x": 38.61994945069005, "y": -122.43819529796752, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bd48a076-5f8f-426a-b294-183700d1a123", "name": "p1rlv17069", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3b30dab7-8ea2-4d20-afae-2bb1a6efded1"}}}}, {"uuid": "a2a5e5d8-edf7-451c-b710-08f3ebe5620f", "name": "", "x": 38.60637102325893, "y": -122.45140950104778, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a6c5d7ff-cfcd-4b30-98db-eb44a95d6841", "name": "p1rdt8015lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a2a5e5d8-edf7-451c-b710-08f3ebe5620f"}}}}, {"uuid": "6a96ff2a-cd9b-4d06-8c13-ef04fa2bd59d", "name": "", "x": 38.60632273742159, "y": -122.45132550281518, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f23214ee-3032-4403-9084-8117e89cb1cf", "name": "p1rlv17001", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a96ff2a-cd9b-4d06-8c13-ef04fa2bd59d"}}}}, {"uuid": "d18a87e9-8f1c-4a7a-bf3f-195c6b8f25a2", "name": "", "x": 38.60636860276844, "y": -122.45149742797311, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "213e6d98-ad57-4034-b2d0-4b096554cac2", "name": "p1rlv17028", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d18a87e9-8f1c-4a7a-bf3f-195c6b8f25a2"}}}}, {"uuid": "74928a51-a3eb-4475-a089-b643f8e3cddd", "name": "", "x": 38.620582059906845, "y": -122.43797607749299, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "972fe574-f88e-4a8d-8845-d5baa2f378a7", "name": "p1rdt8034lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "74928a51-a3eb-4475-a089-b643f8e3cddd"}}}}, {"uuid": "57807a14-3fcd-490d-a976-2296f5ca4a86", "name": "", "x": 38.620214408134636, "y": -122.43835802321873, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "92aff718-b70f-4ea4-b38b-fae69a470c58", "name": "p1rlv17059", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "57807a14-3fcd-490d-a976-2296f5ca4a86"}}}}, {"uuid": "652294b0-563d-4bfd-b434-dcdbf4f1f2c8", "name": "", "x": 38.59894295708058, "y": -122.46830816449578, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9951633b-4311-4ca2-9316-3801be13fe97", "name": "p1rdt8149lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "652294b0-563d-4bfd-b434-dcdbf4f1f2c8"}}}}, {"uuid": "24cd4106-fd1e-4e94-a044-53af52c6d2ca", "name": "", "x": 38.598821308346544, "y": -122.46812594296912, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d9778ed5-f0c0-44de-b0d4-60659a54fa3b", "name": "p1rlv17319", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "24cd4106-fd1e-4e94-a044-53af52c6d2ca"}}}}, {"uuid": "f10ee951-5720-4c53-bd7f-7ff21679759b", "name": "", "x": 38.598867566369016, "y": -122.46838972837861, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4970bc03-bc57-4a42-b0cb-66002af1709e", "name": "p1rlv17334", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f10ee951-5720-4c53-bd7f-7ff21679759b"}}}}, {"uuid": "be323039-e11a-4d50-ae15-10c1ce1c9187", "name": "", "x": 38.59870152218132, "y": -122.4669250043453, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6cd1ae47-6aaa-4b57-ba44-1e74f6ea54b7", "name": "p1rdt8150lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be323039-e11a-4d50-ae15-10c1ce1c9187"}}}}, {"uuid": "2876bba6-9299-413f-b90c-6f858847f3c5", "name": "", "x": 38.59827116190417, "y": -122.46741050201447, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "79991b02-c0f1-4b9b-a55e-e9b4ff7c17d9", "name": "p1rlv17320", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2876bba6-9299-413f-b90c-6f858847f3c5"}}}}, {"uuid": "7dbc0a5b-096f-467d-8654-2443b4048e03", "name": "", "x": 38.599111058885946, "y": -122.46644716803104, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6ceb2d77-2da7-44df-9f28-69ed35835775", "name": "p1rlv17326", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7dbc0a5b-096f-467d-8654-2443b4048e03"}}}}, {"uuid": "7e3afdac-e798-4f5f-a6bf-8b16a3ecc303", "name": "", "x": 38.599727655355764, "y": -122.4681198081272, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75a8deb5-b46b-4d4c-876c-b44b2258a6fa", "name": "p1rdt8151lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7e3afdac-e798-4f5f-a6bf-8b16a3ecc303"}}}}, {"uuid": "65e01278-ee98-422b-a1ee-5e7071567570", "name": "", "x": 38.599692587118206, "y": -122.46815246602429, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "00ed745d-78ae-47f6-b6ef-4edf8794ca6a", "name": "p1rdt8151lv-p1rlv17321x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65e01278-ee98-422b-a1ee-5e7071567570"}}}}, {"uuid": "e413bf90-133e-4824-8fae-b54739e28318", "name": "", "x": 38.599654808831716, "y": -122.46817784954497, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "94ce8ee2-6f57-407a-93e9-c06f79d66262", "name": "p1rdt8151lv-p1rlv17321xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e413bf90-133e-4824-8fae-b54739e28318"}}}}, {"uuid": "b16cfa2e-327a-4cd1-af35-0b3f8d8e6192", "name": "", "x": 38.59971750379885, "y": -122.46702835755418, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ce41ac7c-06c5-435a-957d-c9dda83c1893", "name": "p1rlv17321", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b16cfa2e-327a-4cd1-af35-0b3f8d8e6192"}}}}, {"uuid": "51b25475-572c-43ef-b08b-4bc4bc2e516d", "name": "", "x": 38.599821698957996, "y": -122.46814152774704, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "abb24254-be79-45d4-8d9b-246b3e89c00f", "name": "p1rlv20188", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "51b25475-572c-43ef-b08b-4bc4bc2e516d"}}}}, {"uuid": "73645010-aad0-4777-9ab9-4d588ae8adc5", "name": "", "x": 38.59932106464093, "y": -122.4698880830305, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7a542ca5-b24e-44dc-8b68-c00aa024afad", "name": "p1rdt8153lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "73645010-aad0-4777-9ab9-4d588ae8adc5"}}}}, {"uuid": "bcc547e6-c25f-4156-a23e-52ef6e3c66a3", "name": "", "x": 38.59930726241313, "y": -122.4699390974389, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9b96606c-9336-4299-be8d-295c84943a9d", "name": "p1rlv17325", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bcc547e6-c25f-4156-a23e-52ef6e3c66a3"}}}}, {"uuid": "12a4a536-86b1-4eea-a894-3802183a70e7", "name": "", "x": 38.5995160751222, "y": -122.47116135904078, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32fefbef-e10b-4758-8c2e-ccafad49aa5d", "name": "p1rdt8154lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "12a4a536-86b1-4eea-a894-3802183a70e7"}}}}, {"uuid": "bc792def-db51-4a96-a8b0-19f05e3269c4", "name": "", "x": 38.59950227233904, "y": -122.4712123733502, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a43eb022-d5e0-47c8-aa36-6ca0d212ab07", "name": "p1rlv17328", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bc792def-db51-4a96-a8b0-19f05e3269c4"}}}}, {"uuid": "c3d91646-a40b-40ca-80bb-61f7e6f26a01", "name": "", "x": 38.598945724578684, "y": -122.46814818814434, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "51812cd8-eec8-4862-8413-d25a7e9862dc", "name": "p1rdt8155lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c3d91646-a40b-40ca-80bb-61f7e6f26a01"}}}}, {"uuid": "fc85bc7f-eb62-491d-a8dd-e16c26eaa370", "name": "", "x": 38.59855694337255, "y": -122.46746183798086, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "61ef37c1-f14f-4b79-a428-d51a6f0d076a", "name": "p1rlv17329", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fc85bc7f-eb62-491d-a8dd-e16c26eaa370"}}}}, {"uuid": "85a37c02-3c14-40bb-9d81-588a0997012f", "name": "", "x": 38.59929944436906, "y": -122.4682372527046, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cb2a5041-28a1-4fda-905b-caf53ebbefe3", "name": "p1rdm17903", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "85a37c02-3c14-40bb-9d81-588a0997012f"}}}}, {"uuid": "600dd5af-b1ef-4e7d-9206-2af3992c0b0d", "name": "", "x": 38.599299287824266, "y": -122.46820280233233, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48ad7bb0-8dd7-457a-b77d-6db2071c2fe7", "name": "p1rlv17330", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "600dd5af-b1ef-4e7d-9206-2af3992c0b0d"}}}}, {"uuid": "c6354fad-0bf0-4b9f-8e5b-9393b20d716a", "name": "", "x": 38.59897593725153, "y": -122.46956906444683, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fa6d4429-8a95-4ebd-9e3a-9867734245bd", "name": "p1rdt8157lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c6354fad-0bf0-4b9f-8e5b-9393b20d716a"}}}}, {"uuid": "bafc48cf-5d8c-4306-98a9-d215091f7b50", "name": "", "x": 38.598949958035, "y": -122.46952646674691, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33b66eb9-3b21-4f92-b19b-6a0eef4134d8", "name": "p1rlv17333", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bafc48cf-5d8c-4306-98a9-d215091f7b50"}}}}, {"uuid": "90af01ca-1950-494d-b325-b227d69c91bf", "name": "", "x": 38.64315249575866, "y": -122.47114976892446, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e1dd4660-3cd0-4709-b1ef-1c598e5e39fb", "name": "p1rdt8159lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "90af01ca-1950-494d-b325-b227d69c91bf"}}}}, {"uuid": "fb4f265f-b768-470b-b88f-c854b51fcff9", "name": "", "x": 38.64322634740489, "y": -122.47091189149079, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a5d0a174-d49d-4c7e-a669-092f6408edf4", "name": "p1rlv20480", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fb4f265f-b768-470b-b88f-c854b51fcff9"}}}}, {"uuid": "e08079d3-edd1-4bc8-b081-44dd5362f947", "name": "", "x": 38.64301980977188, "y": -122.47107428162515, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3484e698-3a4e-4a88-aaa3-1dc88cd9ac89", "name": "p1rdm17907", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e08079d3-edd1-4bc8-b081-44dd5362f947"}}}}, {"uuid": "bda4f4c6-ba52-422b-bb2d-4154135e8feb", "name": "", "x": 38.64306413997204, "y": -122.47091308420728, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0b645969-9136-42a9-b5ac-7d2f1ff71959", "name": "p1rlv17336", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bda4f4c6-ba52-422b-bb2d-4154135e8feb"}}}}, {"uuid": "cea73a9b-9f97-4242-820d-0a18752b434b", "name": "", "x": 38.643206712841376, "y": -122.47055581957126, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7af262b7-285c-4d06-b7ff-2f2a1971055a", "name": "p1rlv20492", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cea73a9b-9f97-4242-820d-0a18752b434b"}}}}, {"uuid": "dcb6e9c3-b78b-427f-835d-56f4c83eb710", "name": "", "x": 38.64331796921429, "y": -122.47124445290501, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6112cc26-bc37-4c72-8ef6-cd88f1296693", "name": "p1rdm17908", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dcb6e9c3-b78b-427f-835d-56f4c83eb710"}}}}, {"uuid": "0b5adf50-29df-4ada-9ca9-a7c149090ecb", "name": "", "x": 38.64340709749659, "y": -122.47102547122093, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8934db59-0c39-4838-9f8c-59a563cd9d54", "name": "p1rlv20455", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0b5adf50-29df-4ada-9ca9-a7c149090ecb"}}}}, {"uuid": "4410ab61-f4d7-4686-b7a5-9283f71a955f", "name": "", "x": 38.647797936596966, "y": -122.46665816549304, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "232fed6b-fe0f-4a44-93e9-e6675b50c39c", "name": "p1rdt8160lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4410ab61-f4d7-4686-b7a5-9283f71a955f"}}}}, {"uuid": "6ba1a4ef-2877-4400-a039-d27b9912e1d2", "name": "", "x": 38.64781228772558, "y": -122.4667089672996, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d5d7049e-9d30-474c-9033-3ad9b4487f7a", "name": "p1rlv17337", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6ba1a4ef-2877-4400-a039-d27b9912e1d2"}}}}, {"uuid": "a8334a25-2ec8-45e1-90a0-56ac56a0edc3", "name": "", "x": 38.644602062665655, "y": -122.47222549352858, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ac7e489e-7249-4702-9ed6-131cad34500f", "name": "p1rdt8161lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8334a25-2ec8-45e1-90a0-56ac56a0edc3"}}}}, {"uuid": "14ba7656-3e7a-48eb-84c9-cff77db459fd", "name": "", "x": 38.644748791082094, "y": -122.47278523601162, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "331389ab-5d04-4648-83b4-3043198c774f", "name": "p1rlv17338", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "14ba7656-3e7a-48eb-84c9-cff77db459fd"}}}}, {"uuid": "0680cc6e-da56-4ac2-b868-8618f91b4a6a", "name": "", "x": 38.617206962751396, "y": -122.42934627658663, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9560197a-21d1-4601-8bcb-213df4844f4a", "name": "p1rdt8346lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0680cc6e-da56-4ac2-b868-8618f91b4a6a"}}}}, {"uuid": "87600d73-a33f-43c6-92ff-0cbccc7eef41", "name": "", "x": 38.61718096900156, "y": -122.4293036828715, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7acb4e7d-cb06-4848-952d-7c68bb34b6db", "name": "p1rlv17702", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "87600d73-a33f-43c6-92ff-0cbccc7eef41"}}}}, {"uuid": "d12a0724-e31b-404e-8bac-0c3f130fa7e6", "name": "", "x": 38.61731941811156, "y": -122.46431093057339, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "408d5d7b-fc71-46bb-8de0-2d4e628c29b6", "name": "p1rdt8405lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d12a0724-e31b-404e-8bac-0c3f130fa7e6"}}}}, {"uuid": "59b1e009-bbd6-4229-8a8f-0ffc8ba2fd39", "name": "", "x": 38.61734493344011, "y": -122.46426786943886, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a52db2ff-b782-40c1-828a-c65f6929b2fc", "name": "p1rlv17781", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59b1e009-bbd6-4229-8a8f-0ffc8ba2fd39"}}}}, {"uuid": "4baa2cfd-b95d-4843-9f15-6446ca83fe8b", "name": "", "x": 38.62043416913732, "y": -122.45626485935486, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3fe0f77-a7c1-48e3-94aa-30b69f20ca65", "name": "p1rdt8408lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4baa2cfd-b95d-4843-9f15-6446ca83fe8b"}}}}, {"uuid": "1eae8901-0307-473a-a766-33150cf5b60b", "name": "", "x": 38.62067425594847, "y": -122.4561786638706, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9c9c1d9f-eeff-454f-b3d0-7e7de837694c", "name": "p1rlv17787", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1eae8901-0307-473a-a766-33150cf5b60b"}}}}, {"uuid": "bab9d82d-9b34-48ac-b25c-565c4824842b", "name": "", "x": 38.62014326917501, "y": -122.45633200676872, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b40fac8c-a99b-4baa-940a-26565ba7d62b", "name": "p1rlv18044", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bab9d82d-9b34-48ac-b25c-565c4824842b"}}}}, {"uuid": "c80213c4-13ed-4f25-a3db-f0e44ee86016", "name": "", "x": 38.62377947083559, "y": -122.45617863919693, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fca92353-c013-4c41-8507-ec8704410834", "name": "p1rdt8414lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c80213c4-13ed-4f25-a3db-f0e44ee86016"}}}}, {"uuid": "3bbdb11f-382f-4722-98b6-18945dc957b4", "name": "", "x": 38.623816236226766, "y": -122.4555001331194, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d9dba02d-086c-4906-9c6f-86532e3384c0", "name": "p1rlv17798", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3bbdb11f-382f-4722-98b6-18945dc957b4"}}}}, {"uuid": "f094ddcf-5d31-4a5f-853f-8314aa17aa7b", "name": "", "x": 38.59895000377746, "y": -122.46337821887984, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cfe35c35-8164-4825-81e3-10a2ece2cb27", "name": "p1rdt8422lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f094ddcf-5d31-4a5f-853f-8314aa17aa7b"}}}}, {"uuid": "0036a891-6aaf-4b34-8cf0-810e4e8d6bf0", "name": "", "x": 38.59842227673629, "y": -122.46362727672292, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3887a879-0783-4703-8a24-32b7e3b4f39d", "name": "p1rlv17810", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0036a891-6aaf-4b34-8cf0-810e4e8d6bf0"}}}}, {"uuid": "b81a4b3e-aeac-4baf-bc74-00bc42937f30", "name": "", "x": 38.59798139328054, "y": -122.46377984508203, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6f7776e4-a81f-48d2-b3c0-d70bfa48164e", "name": "p1rlv17847", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b81a4b3e-aeac-4baf-bc74-00bc42937f30"}}}}, {"uuid": "6e44a3e6-b8a2-4262-8184-2c558056127d", "name": "", "x": 38.598224600790864, "y": -122.46375506824658, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75e55237-b847-4fb7-a141-a0771bd868c6", "name": "p1rlv17876", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6e44a3e6-b8a2-4262-8184-2c558056127d"}}}}, {"uuid": "3e55eaf4-6618-482f-b4e3-c232453615b3", "name": "", "x": 38.59902589482566, "y": -122.46358833294255, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a7421f5c-bf5c-4d01-aa14-ba657f242080", "name": "p1rdm18545", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e55eaf4-6618-482f-b4e3-c232453615b3"}}}}, {"uuid": "e8a52517-868f-4231-8bad-cc741df29cce", "name": "", "x": 38.598360195447086, "y": -122.46384592887894, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2716887e-1701-4a78-805b-96da0781c7f8", "name": "p1rlv17961", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e8a52517-868f-4231-8bad-cc741df29cce"}}}}, {"uuid": "0ddbc6a9-40f9-4e00-a77f-e50a854446b3", "name": "", "x": 38.597552657762314, "y": -122.45740568785139, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cdc5ef2a-c0d0-4702-b6c6-df08af1e8746", "name": "p1rdt8434lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0ddbc6a9-40f9-4e00-a77f-e50a854446b3"}}}}, {"uuid": "c280eb31-f020-492f-8511-02bbf631c40b", "name": "", "x": 38.59741052481255, "y": -122.45723847553955, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0827675c-2467-403d-822e-5f74cd6296c5", "name": "p1rlv17857", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c280eb31-f020-492f-8511-02bbf631c40b"}}}}, {"uuid": "e0797818-9133-4fd4-93f8-5ecdb12592b1", "name": "", "x": 38.59577787216432, "y": -122.45996961185554, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b24c9345-625f-499d-96cf-30b2de5839b6", "name": "p1rdt8436lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e0797818-9133-4fd4-93f8-5ecdb12592b1"}}}}, {"uuid": "6b2266b6-8a5f-4e6d-8b4b-b4d91bf314c5", "name": "", "x": 38.59575188947818, "y": -122.45992701953358, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f44b0293-61e5-4054-b2d7-4a113df92b3c", "name": "p1rlv17877", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6b2266b6-8a5f-4e6d-8b4b-b4d91bf314c5"}}}}, {"uuid": "235a5cab-5833-447d-938d-8458cbfe5858", "name": "", "x": 38.61790022449083, "y": -122.4571375571412, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a38f544-e250-4fc9-942c-946c5cde0a33", "name": "p1rdt8439lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "235a5cab-5833-447d-938d-8458cbfe5858"}}}}, {"uuid": "ae72de9d-225e-480d-9e53-9d298035cd06", "name": "", "x": 38.61807504073576, "y": -122.45730102691826, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3f74f217-4765-406d-9646-d8f46377ef0a", "name": "p1rlv17897", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ae72de9d-225e-480d-9e53-9d298035cd06"}}}}, {"uuid": "d1f565f4-1b19-4624-acab-6843789b0f04", "name": "", "x": 38.597579593964674, "y": -122.45871858209406, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c6460e5c-839d-4f9e-b9d6-b187fddb9ab6", "name": "p1rdm18631", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1f565f4-1b19-4624-acab-6843789b0f04"}}}}, {"uuid": "e30f89b8-4654-434d-a298-685c0c334130", "name": "", "x": 38.59739305808095, "y": -122.45930564328731, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ab733d49-bb36-4631-8824-1967f98f758a", "name": "p1rlv17909", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e30f89b8-4654-434d-a298-685c0c334130"}}}}, {"uuid": "b0e348c6-668d-45f5-89d6-80130a49de58", "name": "", "x": 38.59774507812581, "y": -122.45881317872153, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "049362b4-49de-4e80-921e-ff763aaab2d1", "name": "p1rdt8440lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b0e348c6-668d-45f5-89d6-80130a49de58"}}}}, {"uuid": "6eb673d0-753b-41b4-9d72-6e3b93827970", "name": "", "x": 38.59785985557703, "y": -122.45891169861048, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7633fe6b-a48b-4e7d-90e6-a38b8a861936", "name": "p1rdm18632", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6eb673d0-753b-41b4-9d72-6e3b93827970"}}}}, {"uuid": "7b013b37-85eb-43c0-8866-e81aa9d95460", "name": "", "x": 38.59783092542888, "y": -122.45911464995726, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1ccaf70a-35d8-4f16-b632-e282fe30b5ca", "name": "p1rlv17969", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7b013b37-85eb-43c0-8866-e81aa9d95460"}}}}, {"uuid": "50b1484b-4818-4428-9e9a-3bde30411fd7", "name": "", "x": 38.592426036395636, "y": -122.46351864990689, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "72c8f08a-0ba5-413e-a805-f9436b41ff29", "name": "p1rdt8441lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "50b1484b-4818-4428-9e9a-3bde30411fd7"}}}}, {"uuid": "a04c8189-e692-459c-a5f1-48dde6ab4744", "name": "", "x": 38.59244738401374, "y": -122.46362580620794, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3eb66d3-0271-4842-8893-9a58f64e0279", "name": "p1rlv17912", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a04c8189-e692-459c-a5f1-48dde6ab4744"}}}}, {"uuid": "8a776ad0-780d-4247-ade1-f5cf9ea31a4b", "name": "", "x": 38.597607065823205, "y": -122.46357324186411, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6b5ae28a-95f8-4023-aa23-36809fe96b10", "name": "p1rdt8442lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8a776ad0-780d-4247-ade1-f5cf9ea31a4b"}}}}, {"uuid": "b197b384-d376-4d94-876a-0a809b11da97", "name": "", "x": 38.597593266344134, "y": -122.46362425623258, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2812bbb1-0bb0-499f-a394-0995784bb7bc", "name": "p1rlv17926", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b197b384-d376-4d94-876a-0a809b11da97"}}}}, {"uuid": "867451dd-75d8-47b5-bd21-ccfa0b329ea5", "name": "", "x": 38.59572176348798, "y": -122.45708645620138, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "978920e8-edf9-4bee-85f9-45f4081ed0ca", "name": "p1rdt8444lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "867451dd-75d8-47b5-bd21-ccfa0b329ea5"}}}}, {"uuid": "105845cf-c40d-4173-81fd-b74861397ce6", "name": "", "x": 38.59568814197167, "y": -122.45699881396531, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "215a5974-e23b-46f0-bde9-f5ad16fdfaf8", "name": "p1rlv17960", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "105845cf-c40d-4173-81fd-b74861397ce6"}}}}, {"uuid": "10f191de-e023-4808-85f5-012176f1336e", "name": "", "x": 38.595797079946, "y": -122.45717024246757, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "86917829-123c-4fda-9809-dc61430a9fef", "name": "p1rlv18071", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10f191de-e023-4808-85f5-012176f1336e"}}}}, {"uuid": "e52bb183-08e0-4285-8429-5d7606c19fe0", "name": "", "x": 38.61751627823996, "y": -122.46078567224485, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7e0923da-550b-479f-b3d8-3e0320db6701", "name": "p1rdt8445lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e52bb183-08e0-4285-8429-5d7606c19fe0"}}}}, {"uuid": "a8649d36-5197-4a25-b6b5-550f77429a73", "name": "", "x": 38.61713929235215, "y": -122.46152369067127, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ec99daac-e0be-4ea1-ba4f-185d4943396d", "name": "p1rlv17962", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8649d36-5197-4a25-b6b5-550f77429a73"}}}}, {"uuid": "664da3a5-5133-402f-8d86-f3c67ca71d77", "name": "", "x": 38.62155491914008, "y": -122.45674368662482, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5dbc3459-6a17-4075-899a-6aab16fb3ab7", "name": "p1rdt8447lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "664da3a5-5133-402f-8d86-f3c67ca71d77"}}}}, {"uuid": "98a16178-ae9b-49b9-9dba-5f7325d4f142", "name": "", "x": 38.6215289352912, "y": -122.45670108034808, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0771ebfa-5eaf-4ae8-94f1-86de7a656f58", "name": "p1rlv17987", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "98a16178-ae9b-49b9-9dba-5f7325d4f142"}}}}, {"uuid": "605fd3a1-c920-45b2-ad64-ca60322bc1c0", "name": "", "x": 38.59745455680166, "y": -122.45591485249561, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8b4216c8-9e99-446c-ad09-5a09f046dd59", "name": "p1rdt8450lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "605fd3a1-c920-45b2-ad64-ca60322bc1c0"}}}}, {"uuid": "f8e8c7c1-26b6-495f-9e34-86907f86c0ad", "name": "", "x": 38.597480069191974, "y": -122.45587180037909, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4aeda1c7-41be-43c8-82e5-d7a347db86a8", "name": "p1rlv18053", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f8e8c7c1-26b6-495f-9e34-86907f86c0ad"}}}}, {"uuid": "ac621d29-9618-4700-9b16-28e6618b6676", "name": "", "x": 38.623331409033426, "y": -122.45649925442898, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d094b779-ebcc-4837-9ccb-31808e2a544b", "name": "p1rdt8456lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ac621d29-9618-4700-9b16-28e6618b6676"}}}}, {"uuid": "722dda28-849d-4e17-a584-550e06ef2a68", "name": "", "x": 38.62321497484187, "y": -122.45604459936547, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c4863d28-4ee2-479d-accb-60b54f472fe7", "name": "p1rlv18100", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "722dda28-849d-4e17-a584-550e06ef2a68"}}}}, {"uuid": "dc23a352-01e5-4e67-9210-bb6fbafba6c4", "name": "", "x": 38.62104504107823, "y": -122.4556217772947, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e597d8da-e876-44a5-a109-1ce84527c557", "name": "p1rdt8458lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dc23a352-01e5-4e67-9210-bb6fbafba6c4"}}}}, {"uuid": "f36410e9-465d-44f3-8ab5-6e0fd2624084", "name": "", "x": 38.62101905682373, "y": -122.45557917172717, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "115a848f-f6f3-48f0-9f33-5a9103f1a892", "name": "p1rlv18129", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f36410e9-465d-44f3-8ab5-6e0fd2624084"}}}}, {"uuid": "804f0048-b140-4280-ba5b-87306c6feacc", "name": "", "x": 38.6478890270985, "y": -122.44178196559784, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "edb15d92-f98a-4fa2-8129-ad8a39e0dc0c", "name": "p1rdt8470lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "804f0048-b140-4280-ba5b-87306c6feacc"}}}}, {"uuid": "4ba6adc1-6162-4155-a2bd-22b86bf1188e", "name": "", "x": 38.6478781196749, "y": -122.4418348710007, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "431692e5-2917-41ea-aafc-96be180b7e27", "name": "p1rlv18166", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ba6adc1-6162-4155-a2bd-22b86bf1188e"}}}}, {"uuid": "b73e98fa-cf90-4060-8e49-9e9faf47c7fb", "name": "", "x": 38.59296538348102, "y": -122.52138816471086, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a84e1424-7faf-4077-9461-b39460f10ef0", "name": "p1rdt8490lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b73e98fa-cf90-4060-8e49-9e9faf47c7fb"}}}}, {"uuid": "ed117aae-82ac-4c66-942a-b71b10ab7463", "name": "", "x": 38.59301371324328, "y": -122.5214951600568, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1c3e08a8-ea88-423d-b361-69509f7ab8fa", "name": "p1rlv18192", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ed117aae-82ac-4c66-942a-b71b10ab7463"}}}}, {"uuid": "5ebb3cfc-a5b0-49a9-a24f-877580473c4b", "name": "", "x": 38.59294983327106, "y": -122.521300375614, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5a7cb078-af6c-4cd5-9aca-48f515f6e711", "name": "p1rlv18198", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ebb3cfc-a5b0-49a9-a24f-877580473c4b"}}}}, {"uuid": "de057e16-abb7-41f6-af51-aebbadc2b25b", "name": "", "x": 38.59325808671421, "y": -122.5203178073169, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "127e4cc7-6413-4482-9ec3-40f8bde02d0c", "name": "p1rdt8492lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "de057e16-abb7-41f6-af51-aebbadc2b25b"}}}}, {"uuid": "ef8d5eb6-940c-46a1-831a-9669016160a2", "name": "", "x": 38.59327241449537, "y": -122.5203685817209, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c5e240e8-b27d-4181-a7ee-a004d3f5c58a", "name": "p1rlv18197", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef8d5eb6-940c-46a1-831a-9669016160a2"}}}}, {"uuid": "a61ec7ca-3ace-4736-9144-904c04e0c148", "name": "", "x": 38.60984174522787, "y": -122.47657385883775, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "95a1a7c7-6055-47c9-a742-c1b81f6c7478", "name": "p1rdt8802lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a61ec7ca-3ace-4736-9144-904c04e0c148"}}}}, {"uuid": "a6e85fe6-c716-4a0f-a8c2-0f24fd3a2386", "name": "", "x": 38.609856091968865, "y": -122.47662463597939, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9178fdee-311f-40f5-bdd6-9b474a05247e", "name": "p1rlv18960", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a6e85fe6-c716-4a0f-a8c2-0f24fd3a2386"}}}}, {"uuid": "2f141231-7a01-4055-8435-d27aaab6e5a0", "name": "", "x": 38.60811019336638, "y": -122.4764535430088, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "715c92fa-2470-4869-8d5f-0b4f3f8360d4", "name": "p1rdt8805lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2f141231-7a01-4055-8435-d27aaab6e5a0"}}}}, {"uuid": "8dee19e0-8f93-421c-89dc-21a73c4b7405", "name": "", "x": 38.60841504125986, "y": -122.4772548473748, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eef4f0cf-6e51-45e1-8b6e-84171f7cbef6", "name": "p1rlv18967", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8dee19e0-8f93-421c-89dc-21a73c4b7405"}}}}, {"uuid": "44c9f757-2bb1-4fa1-b546-bd34b4b7f2f9", "name": "", "x": 38.581410942364535, "y": -122.50908841868979, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f6ff626c-d2fc-4b97-9013-4fd544d946a2", "name": "p1rdt8898lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "44c9f757-2bb1-4fa1-b546-bd34b4b7f2f9"}}}}, {"uuid": "57fd1592-5243-4363-8282-086d2487b045", "name": "", "x": 38.58102797028686, "y": -122.50847493360112, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2cf28b5d-d8d4-4883-a396-2d1ad9b70564", "name": "p1rlv19157", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "57fd1592-5243-4363-8282-086d2487b045"}}}}, {"uuid": "f3f75cf1-080c-47d4-977e-453e2b885282", "name": "", "x": 38.58165154784808, "y": -122.50878549370569, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "09d59048-6e1b-4f7f-b161-81163809eb25", "name": "p1rdm19752", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f3f75cf1-080c-47d4-977e-453e2b885282"}}}}, {"uuid": "e8ccc470-71ba-4c98-aee7-701cc49838f9", "name": "", "x": 38.581235479806075, "y": -122.50853092416536, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "67a4600d-65c3-40d7-ad28-e8e37ff77dcb", "name": "p1rlv19149", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e8ccc470-71ba-4c98-aee7-701cc49838f9"}}}}, {"uuid": "b56887ea-0407-49d2-a1d7-9cbc77058ca0", "name": "", "x": 38.581243768243056, "y": -122.5083586529402, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c7c1d210-ee87-46c5-b408-ad221cbeed04", "name": "p1rlv19160", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b56887ea-0407-49d2-a1d7-9cbc77058ca0"}}}}, {"uuid": "240e4997-1186-4c77-b45b-065a2ebd972c", "name": "", "x": 38.58115574730252, "y": -122.50928817819602, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a7664d29-bbc0-4465-a00a-82af048b86e5", "name": "p1rdm19755", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "240e4997-1186-4c77-b45b-065a2ebd972c"}}}}, {"uuid": "2d04d1e5-eafb-4f34-b561-44619bce9aa4", "name": "", "x": 38.58064928716368, "y": -122.50843159103809, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "994f6392-f4e5-4ff8-9eeb-5849cd035912", "name": "p1rlv19166", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2d04d1e5-eafb-4f34-b561-44619bce9aa4"}}}}, {"uuid": "e8c464bc-8647-472f-ae74-067475e1724b", "name": "", "x": 38.58121826088946, "y": -122.50725268309377, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d53c0a2-78cc-4988-85a4-884ef039f5fa", "name": "p1rdt8901lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e8c464bc-8647-472f-ae74-067475e1724b"}}}}, {"uuid": "11091ed9-9278-418b-a4b8-3759b0797ce7", "name": "", "x": 38.58123620687723, "y": -122.50802972585609, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16df6b90-d049-4160-b148-b888e03acb82", "name": "p1rlv19161", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "11091ed9-9278-418b-a4b8-3759b0797ce7"}}}}, {"uuid": "064e0b49-6ead-4a53-af44-38565a7e6781", "name": "", "x": 38.65991234943945, "y": -122.43854233081237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e111e213-bcbe-42c4-b6ab-2c734ff5341c", "name": "p1rdt8904lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "064e0b49-6ead-4a53-af44-38565a7e6781"}}}}, {"uuid": "40047848-7a14-4001-aecf-88ae0011c629", "name": "", "x": 38.660223463841156, "y": -122.43823709517063, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1f8c76ca-40ea-4f7d-8042-66edd484f065", "name": "p1rlv19168", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "40047848-7a14-4001-aecf-88ae0011c629"}}}}, {"uuid": "f8047d0f-fd7f-4cd1-a199-62ef50463692", "name": "", "x": 38.659990269866015, "y": -122.43846878718209, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e0fc7d43-4f82-4100-99bf-6e30e03e95ce", "name": "p1rlv19174", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f8047d0f-fd7f-4cd1-a199-62ef50463692"}}}}, {"uuid": "184974a9-5002-4bab-bace-c579e696241d", "name": "", "x": 38.659792348994905, "y": -122.43853929357995, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8b9386f2-376d-4439-a9a4-3eefc238dafe", "name": "p1rdm19776", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "184974a9-5002-4bab-bace-c579e696241d"}}}}, {"uuid": "97d3a98b-859b-4c49-9814-8854ec2c9ea8", "name": "", "x": 38.659815187445474, "y": -122.43766561018224, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "50750ddb-80db-4d5f-bc62-4bbfc600a7ef", "name": "p1rlv19184", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "97d3a98b-859b-4c49-9814-8854ec2c9ea8"}}}}, {"uuid": "6760425d-5a9c-4a69-a620-335a6a50dd5a", "name": "", "x": 38.66094193321756, "y": -122.4420778873007, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be2777cc-f3fd-491f-a10b-4ed381cb948d", "name": "p1rdt8905lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6760425d-5a9c-4a69-a620-335a6a50dd5a"}}}}, {"uuid": "e4fb0dbb-9f87-44eb-8fc2-c6fa5b3b190c", "name": "", "x": 38.66079928545388, "y": -122.4418071207425, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be4e8183-9148-477e-aa1b-ff31a5324273", "name": "p1rlv19169", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e4fb0dbb-9f87-44eb-8fc2-c6fa5b3b190c"}}}}, {"uuid": "cdebdf2f-ce8a-4206-9a08-febb53cf2595", "name": "", "x": 38.66134282316126, "y": -122.44240057565185, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fffe26f7-c4cc-420e-ab17-754cb0d9e659", "name": "p1rlv19171", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cdebdf2f-ce8a-4206-9a08-febb53cf2595"}}}}, {"uuid": "a3f6aa7b-1b7e-4b4c-99f6-ba8b0c163e86", "name": "", "x": 38.661324142709425, "y": -122.44226279573506, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "21fec301-b67c-4042-a074-caf406c7f0b5", "name": "p1rlv19173", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a3f6aa7b-1b7e-4b4c-99f6-ba8b0c163e86"}}}}, {"uuid": "e1a509d5-5978-458c-b5a3-4a6ad7aa48bb", "name": "", "x": 38.660891099685436, "y": -122.44216271154556, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "47e24942-486d-46f1-a40f-0da5c93c013a", "name": "p1rlv19188", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e1a509d5-5978-458c-b5a3-4a6ad7aa48bb"}}}}, {"uuid": "8daf8c62-fb93-452e-a50f-f20fd4575028", "name": "", "x": 38.660438772467124, "y": -122.44179842559906, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d7daa1d3-6249-447d-a260-65de5ec0a470", "name": "p1rlv19194", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8daf8c62-fb93-452e-a50f-f20fd4575028"}}}}, {"uuid": "f5014d04-b09d-4eb3-ab03-0922624e3ed6", "name": "", "x": 38.65966647434038, "y": -122.44177391418427, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c306f79a-0240-465e-a486-d0f11614fc57", "name": "p1rdt8911lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5014d04-b09d-4eb3-ab03-0922624e3ed6"}}}}, {"uuid": "ef46d329-2e90-4650-bdbe-4d60014873d6", "name": "", "x": 38.659762694003604, "y": -122.44175769963816, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "89bde057-807b-415c-9135-267c6bf43c44", "name": "p1rlv19183", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef46d329-2e90-4650-bdbe-4d60014873d6"}}}}, {"uuid": "f91d9e6c-5898-4087-987a-3ebafb3c94ca", "name": "", "x": 38.659528505871954, "y": -122.44178250448644, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4a8ae6dc-884d-48d8-9995-fe3936ad019c", "name": "p1rlv20296", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f91d9e6c-5898-4087-987a-3ebafb3c94ca"}}}}, {"uuid": "0edbaaa4-6519-455b-9246-8a1c2a9156ca", "name": "", "x": 38.66174426844995, "y": -122.44236029493588, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2fbbca23-6473-4344-ac2e-cc97078b3d8d", "name": "p1rdt8915lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0edbaaa4-6519-455b-9246-8a1c2a9156ca"}}}}, {"uuid": "6b82329d-8f91-4a11-af20-f5eea8feb9c7", "name": "", "x": 38.66176977524987, "y": -122.44231719933447, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5fecc64a-4783-4ecb-a0d0-7e60d1cf6184", "name": "p1rlv19189", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6b82329d-8f91-4a11-af20-f5eea8feb9c7"}}}}, {"uuid": "9b3f7497-3003-404d-b677-bcdb323c6ab4", "name": "", "x": 38.66022824513094, "y": -122.4403032002883, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d268e33-708d-4bae-8348-cad27fd0d81a", "name": "p1rdt8916lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9b3f7497-3003-404d-b677-bcdb323c6ab4"}}}}, {"uuid": "04b52ef4-71da-4abc-bfca-23d50fefdad0", "name": "", "x": 38.66024260770121, "y": -122.44035400544816, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4aee02d4-8663-455b-a197-55b6b1470895", "name": "p1rlv19190", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "04b52ef4-71da-4abc-bfca-23d50fefdad0"}}}}, {"uuid": "3a99f762-bf86-47c2-a9c5-ba32b79116be", "name": "", "x": 38.655203793367576, "y": -122.45620231524185, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6752e8f4-9e37-476d-aec2-4a2fe7c1e2dc", "name": "p1rdt9075lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3a99f762-bf86-47c2-a9c5-ba32b79116be"}}}}, {"uuid": "2f6f79fa-c192-4f73-8fe9-34244be1e20a", "name": "", "x": 38.65518999754597, "y": -122.45625337194336, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33dcb037-4cc8-480f-aac4-bc95e54e165e", "name": "p1rlv19667", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2f6f79fa-c192-4f73-8fe9-34244be1e20a"}}}}, {"uuid": "18e29a87-cfae-409d-a4d0-59cdfda79164", "name": "", "x": 38.659371136386014, "y": -122.45366040420096, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bdd64386-e256-47f8-8cef-1c933f993a29", "name": "p1rdt9076lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "18e29a87-cfae-409d-a4d0-59cdfda79164"}}}}, {"uuid": "510bb7b0-5542-41e1-85d9-ab5f40613641", "name": "", "x": 38.65966620569122, "y": -122.45316394323339, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "14b1ab4e-b22d-4a98-8131-fc72c923c735", "name": "p1rlv19698", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "510bb7b0-5542-41e1-85d9-ab5f40613641"}}}}, {"uuid": "12fed0c5-f799-4023-b80f-43c58a88eefd", "name": "", "x": 38.65923252263959, "y": -122.45353105574254, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fd00c91a-01a8-4aad-b740-b06a654d631b", "name": "p1rdm20204", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "12fed0c5-f799-4023-b80f-43c58a88eefd"}}}}, {"uuid": "6ba53ded-0201-4663-a8a2-5703783675ba", "name": "", "x": 38.65913430903858, "y": -122.45372718962375, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6427f66-2e22-40bb-83f1-2a8b1be9191a", "name": "p1rlv19668", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6ba53ded-0201-4663-a8a2-5703783675ba"}}}}, {"uuid": "7a201e5f-5a2b-4c99-866d-0b8445ce2f1e", "name": "", "x": 38.659402236788104, "y": -122.45320795008209, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48654a82-ac11-4542-94ec-8f731138e1a8", "name": "p1rlv19699", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7a201e5f-5a2b-4c99-866d-0b8445ce2f1e"}}}}, {"uuid": "3219c596-244a-4592-ac08-1498542b882a", "name": "", "x": 38.65946805558687, "y": -122.45379361501921, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ce8f50bb-90fb-49b8-8a16-1bbbb6a0c82c", "name": "p1rdm20205", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3219c596-244a-4592-ac08-1498542b882a"}}}}, {"uuid": "8c0543e4-bfd1-4ea1-abd8-9f20075a02f4", "name": "", "x": 38.65960231517979, "y": -122.45359720642892, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "47f5777d-2c8d-48c2-bf28-386f3f3dbac4", "name": "p1rlv19686", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8c0543e4-bfd1-4ea1-abd8-9f20075a02f4"}}}}, {"uuid": "61eb89b7-5c68-4fe6-a2cf-65b8a9334552", "name": "", "x": 38.652242872397366, "y": -122.46144885825713, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6b83eaaa-a092-42ca-a746-db4d9658d62b", "name": "p1rdt9077lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "61eb89b7-5c68-4fe6-a2cf-65b8a9334552"}}}}, {"uuid": "d2c378d1-16dd-475a-96e9-e684db274429", "name": "", "x": 38.65239205276167, "y": -122.4611909367415, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "96d3079a-02f1-4c89-ad75-fd0a438c9cf4", "name": "p1rlv19669", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d2c378d1-16dd-475a-96e9-e684db274429"}}}}, {"uuid": "955a59ba-ed77-4cb8-ba64-6835fb9101a6", "name": "", "x": 38.65223106297542, "y": -122.46145646522658, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0031ab1b-d82d-40a5-b41e-bc6f6cb53069", "name": "p1rlv19675", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "955a59ba-ed77-4cb8-ba64-6835fb9101a6"}}}}, {"uuid": "54b6622c-d1f3-4f49-9fe9-b34c2b16e965", "name": "", "x": 38.65203392082483, "y": -122.46169927854602, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35fe21a1-f817-426e-9e42-f1f33876dd7d", "name": "p1rlv19695", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "54b6622c-d1f3-4f49-9fe9-b34c2b16e965"}}}}, {"uuid": "52222e5e-929d-40e5-9033-af986edf0e1c", "name": "", "x": 38.658511634388226, "y": -122.45377906068661, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7f0e4f59-8a46-4abf-9f06-e0383a59a45d", "name": "p1rdt9084lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "52222e5e-929d-40e5-9033-af986edf0e1c"}}}}, {"uuid": "7d2fecb9-f2e2-4813-bc4a-f2dd44b73ae1", "name": "", "x": 38.65890081567661, "y": -122.4539013635132, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "83afc678-d577-4ef1-afa2-8e3f915a158b", "name": "p1rlv19681", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7d2fecb9-f2e2-4813-bc4a-f2dd44b73ae1"}}}}, {"uuid": "87d5d0d0-3503-4fb3-90d4-b7010024e8e1", "name": "", "x": 38.65082653264708, "y": -122.46112619224643, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "565bbfb1-a28f-4db2-be48-cbd58972025a", "name": "p1rdt9085lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "87d5d0d0-3503-4fb3-90d4-b7010024e8e1"}}}}, {"uuid": "024c67e1-26f2-4e2d-a9e1-2363314f620e", "name": "", "x": 38.65123799892708, "y": -122.46107316768796, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "811acd48-b61c-4a42-b76e-f995961c450e", "name": "p1rlv19682", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "024c67e1-26f2-4e2d-a9e1-2363314f620e"}}}}, {"uuid": "e9eeb7a0-71f8-42f2-8fde-92047b07a318", "name": "", "x": 38.650795641302004, "y": -122.46090410093127, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ec27727b-2bb8-4df2-9ddf-46282728c2c0", "name": "p1rdm20223", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e9eeb7a0-71f8-42f2-8fde-92047b07a318"}}}}, {"uuid": "0e0f0e38-cf93-421d-b57f-3480c11f4488", "name": "", "x": 38.65132742554806, "y": -122.46092309986851, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1b5d936f-b3e0-408e-aabd-d3ebb7b869b0", "name": "p1rlv19701", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0e0f0e38-cf93-421d-b57f-3480c11f4488"}}}}, {"uuid": "f408d815-1e53-4979-87cd-e7df5fb7d70f", "name": "", "x": 38.65246361026913, "y": -122.46218753579743, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f8108ac8-2807-4a40-85c2-db21efaadadb", "name": "p1rdt9089lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f408d815-1e53-4979-87cd-e7df5fb7d70f"}}}}, {"uuid": "35ae0831-567f-4d28-ba9e-19a634226d71", "name": "", "x": 38.65247796334516, "y": -122.46223833997352, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "578b5df8-1dd8-41d9-b6dc-db75db5b115e", "name": "p1rlv19689", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "35ae0831-567f-4d28-ba9e-19a634226d71"}}}}, {"uuid": "7fb01aed-5f5d-4a4a-8919-592230ce46fe", "name": "", "x": 38.65140101826137, "y": -122.46336158947928, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6fc84159-09b1-4ca9-9a7a-a4fecab19f83", "name": "p1rdt9090lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7fb01aed-5f5d-4a4a-8919-592230ce46fe"}}}}, {"uuid": "67c1af07-75b2-4ed0-80c3-3d37cc36508d", "name": "", "x": 38.651714420003884, "y": -122.4627704444441, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e2709a70-1a7d-454c-90fd-377e416a0071", "name": "p1rlv19690", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "67c1af07-75b2-4ed0-80c3-3d37cc36508d"}}}}, {"uuid": "b8912d59-aeda-43db-8f27-552d50bb9d26", "name": "", "x": 38.650846513531, "y": -122.46155124895908, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1e93ea18-150d-4d80-bac7-f3e1b87c5b4e", "name": "p1rdt9091lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b8912d59-aeda-43db-8f27-552d50bb9d26"}}}}, {"uuid": "ff33634d-a59f-408c-ac9f-96661327410f", "name": "", "x": 38.65126752046812, "y": -122.4616130767133, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b10b272a-2efb-4e19-9921-d4081fb45778", "name": "p1rlv19692", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ff33634d-a59f-408c-ac9f-96661327410f"}}}}, {"uuid": "43134dcc-0533-4dab-bdbd-171362ac4a36", "name": "", "x": 38.65985495091543, "y": -122.45426942925806, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2f0726b7-3050-4c78-9c06-b9fd0c863ff3", "name": "p1rdt9093lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "43134dcc-0533-4dab-bdbd-171362ac4a36"}}}}, {"uuid": "80050a7c-ddcb-47cd-bd59-7f16d2859412", "name": "", "x": 38.65961615387016, "y": -122.45463151295169, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "37f72c85-61f7-4a42-94b0-6a627195458c", "name": "p1rlv19702", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "80050a7c-ddcb-47cd-bd59-7f16d2859412"}}}}, {"uuid": "f4631a44-4de8-418b-94ae-9e7331f02e3b", "name": "", "x": 38.629339299867084, "y": -122.45270506395599, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1c01a9b2-b002-4279-905e-950452f64f32", "name": "p1rdt9264lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f4631a44-4de8-418b-94ae-9e7331f02e3b"}}}}, {"uuid": "27ed1f16-03eb-42ce-8702-a73fa474132f", "name": "", "x": 38.629416853696135, "y": -122.45255114958653, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aaea76fa-797e-46c5-a70f-a973977db841", "name": "p1rlv20064", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "27ed1f16-03eb-42ce-8702-a73fa474132f"}}}}, {"uuid": "881403a8-f760-42b5-8e71-49adf089ec98", "name": "", "x": 38.629219943787845, "y": -122.4528398621658, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ea48ffa1-bdb3-4c15-96c9-ff7d7f34824f", "name": "p1rlv20065", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "881403a8-f760-42b5-8e71-49adf089ec98"}}}}, {"uuid": "b4544aa4-b735-4c64-84e5-139bf0f516a2", "name": "", "x": 38.62682787398021, "y": -122.443538396124, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "77d62813-61d3-4afd-9f21-869e2ea23e17", "name": "p1rdt9265lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b4544aa4-b735-4c64-84e5-139bf0f516a2"}}}}, {"uuid": "d260b95e-211c-4042-a884-17ace9831ea6", "name": "", "x": 38.626801885358226, "y": -122.44349579157367, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f450eeb4-3d87-4ae5-a6d6-958d7efd2712", "name": "p1rlv20066", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d260b95e-211c-4042-a884-17ace9831ea6"}}}}, {"uuid": "88a974e9-a865-4c00-8ffc-1e39aa989a25", "name": "", "x": 38.63354009061449, "y": -122.4470022329432, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "78278589-be2d-4d99-9c03-92c221348917", "name": "p1rdt9266lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "88a974e9-a865-4c00-8ffc-1e39aa989a25"}}}}, {"uuid": "0c7edbb5-8c60-4dd4-8097-98444bf41092", "name": "", "x": 38.6335544502105, "y": -122.44705302069676, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "66a710fb-26c7-4465-b7ea-43ec107008dc", "name": "p1rlv20067", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0c7edbb5-8c60-4dd4-8097-98444bf41092"}}}}, {"uuid": "59e72f91-e9dd-4f26-9cdd-f72aaafbf0b6", "name": "", "x": 38.57668432917656, "y": -122.5244581272183, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "208f222c-45db-445f-ba0b-a4a195ca68a6", "name": "p1rdt9298lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59e72f91-e9dd-4f26-9cdd-f72aaafbf0b6"}}}}, {"uuid": "af9dc8ee-cee4-460f-9c97-b2613c61e390", "name": "", "x": 38.57703900731173, "y": -122.52455160092381, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ffc82be6-f3f8-4a68-b6e6-da60b137329c", "name": "p1rlv20130", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "af9dc8ee-cee4-460f-9c97-b2613c61e390"}}}}, {"uuid": "4d3a48b7-fd17-4c40-ad5a-1107322e7fa2", "name": "", "x": 38.57648055489435, "y": -122.52532048800711, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "180fad26-0e7d-4e2c-ba17-c8e3315ca278", "name": "p1rdt9302lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d3a48b7-fd17-4c40-ad5a-1107322e7fa2"}}}}, {"uuid": "55752a53-a905-418a-94b6-4741fc94dd93", "name": "", "x": 38.57700673397096, "y": -122.52548171913072, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d635a151-2d13-47e9-8043-a214415a5b5e", "name": "p1rlv20138", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "55752a53-a905-418a-94b6-4741fc94dd93"}}}}, {"uuid": "6be69bf2-e2da-4ffd-8e12-9ecb59720f76", "name": "", "x": 38.57718617464166, "y": -122.52237333536553, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d4940a0e-dcc2-45fb-baa9-aadc84f8e882", "name": "p1rdt9310lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6be69bf2-e2da-4ffd-8e12-9ecb59720f76"}}}}, {"uuid": "ab4905b9-4e99-49bb-a83d-8bfaa642964a", "name": "", "x": 38.576705284221035, "y": -122.5222692278727, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9d615e93-a289-41ec-bda0-3b72bf15677e", "name": "p1rlv20146", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ab4905b9-4e99-49bb-a83d-8bfaa642964a"}}}}, {"uuid": "95a5439a-0a5c-4f7b-ae08-bed7b34b0ecf", "name": "", "x": 38.57637456989155, "y": -122.51922519254137, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b9e0aa7d-9097-4370-8f5e-52a5885da85c", "name": "p1rdt9311lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "95a5439a-0a5c-4f7b-ae08-bed7b34b0ecf"}}}}, {"uuid": "85a764e0-e69e-45dc-8957-3b9ca0ab1fd3", "name": "", "x": 38.576279327246795, "y": -122.51948236126216, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16b2add7-6a6d-4359-ad6f-f60edf435a4c", "name": "p1rlv20147", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "85a764e0-e69e-45dc-8957-3b9ca0ab1fd3"}}}}, {"uuid": "88a233ee-71b3-424d-a3b1-cf5eb54ab2a0", "name": "", "x": 38.57622563406502, "y": -122.51957456046857, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e938635b-e0d2-4e1b-a312-5a8f51e1dd7a", "name": "p1rlv20163", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "88a233ee-71b3-424d-a3b1-cf5eb54ab2a0"}}}}, {"uuid": "252394b9-5e80-462d-b1ad-93684148d1b5", "name": "", "x": 38.57944374835563, "y": -122.52129067940982, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0a21f5ca-51ef-4f81-8229-163182f011cf", "name": "p1rdt9312lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "252394b9-5e80-462d-b1ad-93684148d1b5"}}}}, {"uuid": "f1070023-ce6c-4a46-a28b-44adc0b27a78", "name": "", "x": 38.579207205820964, "y": -122.52143752839837, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a4a0c2f2-f75e-4c9c-b3f7-d8d9ada9cb82", "name": "p1rlv20148", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f1070023-ce6c-4a46-a28b-44adc0b27a78"}}}}, {"uuid": "0c82b69e-699d-4e19-95a1-17d14b7c7c9b", "name": "", "x": 38.57963859321071, "y": -122.52114764756729, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "27dfea92-734e-49d3-b245-dc933df66889", "name": "p1rlv20160", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0c82b69e-699d-4e19-95a1-17d14b7c7c9b"}}}}, {"uuid": "aa912d24-a8bb-448b-a77f-ee94b50f811c", "name": "", "x": 38.57499954420577, "y": -122.51877161682458, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3df13d91-365e-411b-917d-b28df5989280", "name": "p1rdt9314lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aa912d24-a8bb-448b-a77f-ee94b50f811c"}}}}, {"uuid": "03254f1e-f392-4daf-802c-1b58ee985315", "name": "", "x": 38.57488526903181, "y": -122.5194726576567, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3eb214b9-827f-4995-a862-907be02b029d", "name": "p1rlv20473", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "03254f1e-f392-4daf-802c-1b58ee985315"}}}}, {"uuid": "99be95b3-5b0a-4a25-88ec-b2a960507eeb", "name": "", "x": 38.57479824917913, "y": -122.51872307044951, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d5930295-0e44-4498-ae22-7647b72c1fa1", "name": "p1rdm20686", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "99be95b3-5b0a-4a25-88ec-b2a960507eeb"}}}}, {"uuid": "fa40295b-b2bc-4dca-a1a5-18c69a4d7b10", "name": "", "x": 38.574765880638516, "y": -122.5196187229471, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "956f4975-7383-4e0b-9114-d333a6ec4005", "name": "p1rlv20151", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa40295b-b2bc-4dca-a1a5-18c69a4d7b10"}}}}, {"uuid": "842bddbc-e3f4-415c-9892-b5c663d506b7", "name": "", "x": 38.57481830117202, "y": -122.51921657510196, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a7a43aa6-2be8-4320-8089-57d388633c6b", "name": "p1rlv20456", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "842bddbc-e3f4-415c-9892-b5c663d506b7"}}}}, {"uuid": "b7d25399-f31a-4e49-adba-a78ff86c5b8b", "name": "", "x": 38.57661532605132, "y": -122.51941521089782, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8c97a99f-545b-49cd-b1fe-4fd9e04bf37f", "name": "p1rdt9316lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b7d25399-f31a-4e49-adba-a78ff86c5b8b"}}}}, {"uuid": "be71b6c1-afc0-467f-8b9b-c08c14272f70", "name": "", "x": 38.57645998524856, "y": -122.51958447974425, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ef20846d-d685-4c65-8dfb-bc23317501c5", "name": "p1rlv20153", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be71b6c1-afc0-467f-8b9b-c08c14272f70"}}}}, {"uuid": "2a99897f-364d-411e-8bbe-72f557ebc745", "name": "", "x": 38.6051181986353, "y": -122.47354850924762, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a68a1c01-a04c-4af6-b1c8-02ddd1d67e0b", "name": "p1rdt9333lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2a99897f-364d-411e-8bbe-72f557ebc745"}}}}, {"uuid": "de597ed3-ec97-4454-aed4-09dd7a03ce13", "name": "", "x": 38.605233794489806, "y": -122.47322379683654, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "20f93381-3834-4265-b1ec-5767d171ce0a", "name": "p1rlv20182", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "de597ed3-ec97-4454-aed4-09dd7a03ce13"}}}}, {"uuid": "c9d78551-0fd5-43ed-8b68-579cb2336594", "name": "", "x": 38.589035386079345, "y": -122.51706377791538, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e98299cb-8bad-49ea-8627-f3cfe01b9e23", "name": "p1rdt9377lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c9d78551-0fd5-43ed-8b68-579cb2336594"}}}}, {"uuid": "d490540a-d433-41f2-b9e7-eca6fa93417a", "name": "", "x": 38.58906092117887, "y": -122.51702075225897, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fb7a8747-a076-469c-a150-35f6763157ec", "name": "p1rlv20277", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d490540a-d433-41f2-b9e7-eca6fa93417a"}}}}, {"uuid": "26eb7692-c5a5-4207-b2ef-2f5b4fc9f7de", "name": "", "x": 38.554956569072154, "y": -122.5078416303234, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9e37f182-5a60-470d-8f5b-ba145cc27973", "name": "p1rdt9381lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "26eb7692-c5a5-4207-b2ef-2f5b4fc9f7de"}}}}, {"uuid": "cff5bde2-44fa-4d0e-a743-f67d7e951b2c", "name": "", "x": 38.55506084687392, "y": -122.50759593781095, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3f23405b-432f-45ff-a7b1-0b7147cddfc8", "name": "p1rlv20281", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cff5bde2-44fa-4d0e-a743-f67d7e951b2c"}}}}, {"uuid": "095f699d-7656-4788-95ba-fb5548a06de8", "name": "", "x": 38.55481960527157, "y": -122.50809108490742, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9e5718ad-0b70-4ea4-b2f2-31f0ea5c5d5b", "name": "p1rlv20309", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "095f699d-7656-4788-95ba-fb5548a06de8"}}}}, {"uuid": "afabc397-de9a-4321-856d-b35e976cd844", "name": "", "x": 38.658604016675696, "y": -122.44126850823349, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "abd09ea6-221c-47d9-beec-1062e0dd4aa7", "name": "p1rdt9384lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "afabc397-de9a-4321-856d-b35e976cd844"}}}}, {"uuid": "fbc5a56d-565b-4454-b6d6-7d72d0bfe51f", "name": "", "x": 38.65866093691784, "y": -122.4412720400857, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25837ab0-0fb8-4346-94ad-561ff9ff7f0c", "name": "p1rlv20284", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fbc5a56d-565b-4454-b6d6-7d72d0bfe51f"}}}}, {"uuid": "1d71f24e-2901-42c3-a813-a3acd99d09c3", "name": "", "x": 38.55588955861104, "y": -122.50676017270496, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fc7e0a25-d6d6-4b07-b3dc-4fe5646915e2", "name": "p1rdt9396lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d71f24e-2901-42c3-a813-a3acd99d09c3"}}}}, {"uuid": "25e2bcaf-cac0-4e8f-91e9-d28d24280f7e", "name": "", "x": 38.55589072497332, "y": -122.5068140409716, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "da62d78e-e221-423a-8da0-8d36ce1f7508", "name": "p1rlv20300", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "25e2bcaf-cac0-4e8f-91e9-d28d24280f7e"}}}}, {"uuid": "1b4f1d5d-7d2c-437f-90c6-9aa0e49f8009", "name": "", "x": 38.62027530963716, "y": -122.47939957508689, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8180ee90-a46e-4d85-9742-d47b24f5e169", "name": "p1rdt9413lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1b4f1d5d-7d2c-437f-90c6-9aa0e49f8009"}}}}, {"uuid": "9fc146a4-e41f-4cf3-b41f-4854efeea77d", "name": "", "x": 38.62004720247463, "y": -122.47879011072362, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c23afdc0-ab93-4d43-8eec-613eab21cd74", "name": "p1rlv20333", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9fc146a4-e41f-4cf3-b41f-4854efeea77d"}}}}, {"uuid": "02cb45f3-fe94-4dd8-9573-6a0f478a879c", "name": "", "x": 38.620529773744515, "y": -122.47990087956352, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4b5d2dfa-895b-4afc-a7fe-449960adba41", "name": "p1rlv20358", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "02cb45f3-fe94-4dd8-9573-6a0f478a879c"}}}}, {"uuid": "e94a07cf-e35c-478c-a311-9ca498f5c3ae", "name": "", "x": 38.591063428696835, "y": -122.52153986948501, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a015abb-ec63-4b31-9314-283b8499646e", "name": "p1rdt9463lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e94a07cf-e35c-478c-a311-9ca498f5c3ae"}}}}, {"uuid": "25620ccf-e94e-4be9-bfe7-91878762980d", "name": "", "x": 38.59108896543552, "y": -122.52149684417888, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e4b5327a-85a3-496c-859c-f887a38513cd", "name": "p1rlv20432", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "25620ccf-e94e-4be9-bfe7-91878762980d"}}}}, {"uuid": "cca09bca-16e9-499c-b095-0c1950ecc547", "name": "", "x": 38.57979403494598, "y": -122.51418658341599, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4dbe1628-cd17-4f37-af2b-dd752c290fa4", "name": "p1rdt9468lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cca09bca-16e9-499c-b095-0c1950ecc547"}}}}, {"uuid": "e157a12b-a7d2-4147-bcd2-b3ab3a70ddae", "name": "", "x": 38.57980836535011, "y": -122.514237347121, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c37708d8-1e83-4e76-ac7f-0d29ba6b7c4e", "name": "p1rlv20451", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e157a12b-a7d2-4147-bcd2-b3ab3a70ddae"}}}}, {"uuid": "f80fb467-df08-4b12-85da-2108e641dcd6", "name": "", "x": 38.64987390299784, "y": -122.46561468579733, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "09613257-d4cb-4c50-b35a-8aefc637c0c9", "name": "p1rdt9469lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f80fb467-df08-4b12-85da-2108e641dcd6"}}}}, {"uuid": "a8be240d-00b9-4f9d-adf9-0f1168744f6a", "name": "", "x": 38.649915988400906, "y": -122.4656103988514, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a4e21b79-d2be-4a53-be46-32331e61f89c", "name": "p1rlv20453", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8be240d-00b9-4f9d-adf9-0f1168744f6a"}}}}, {"uuid": "8860d0ef-e55e-447d-93df-ae60d3936aa0", "name": "", "x": 38.65045746320294, "y": -122.46638434729005, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1ab8727-2758-4513-8a7d-e02381faf1e4", "name": "p1rdt9470lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8860d0ef-e55e-447d-93df-ae60d3936aa0"}}}}, {"uuid": "057230d4-bf01-4042-ad61-30c7db0f897e", "name": "", "x": 38.650379000628085, "y": -122.46634293498136, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9dfcfdbf-0051-4eef-bea6-97446cee21e4", "name": "p1rlv20459", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "057230d4-bf01-4042-ad61-30c7db0f897e"}}}}, {"uuid": "5cf1438a-80c4-4c22-aaed-3469743e85b4", "name": "", "x": 38.65057767311801, "y": -122.46643339731892, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9af153ed-ed39-4433-ac12-19dfdb7b6bef", "name": "p1rlv20499", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5cf1438a-80c4-4c22-aaed-3469743e85b4"}}}}, {"uuid": "7b65f4e9-580d-47dc-b34e-28f81d668390", "name": "", "x": 38.56377829551582, "y": -122.5132715911584, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c14c3211-a0d5-464f-820c-cab04764d907", "name": "p1rdt9473lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7b65f4e9-580d-47dc-b34e-28f81d668390"}}}}, {"uuid": "8a3e10a2-8282-43c8-b4da-fda1b1669c94", "name": "", "x": 38.5639962321023, "y": -122.51298713404236, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4759390d-43ec-45c9-9cca-320020dc1150", "name": "p1rlv20465", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8a3e10a2-8282-43c8-b4da-fda1b1669c94"}}}}, {"uuid": "cb26fbb7-596c-4de9-b34e-101dc678ca65", "name": "", "x": 38.5746780928461, "y": -122.51786998579286, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6a8f268-6a5a-4b23-bd91-53c6b031442a", "name": "p1rdt9479lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb26fbb7-596c-4de9-b34e-101dc678ca65"}}}}, {"uuid": "e39e8d8e-0d46-4628-94c5-07b594071e7e", "name": "", "x": 38.574723226995864, "y": -122.51801181420616, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cacd3e49-55aa-4f05-bd7d-ae8aba0af87f", "name": "p1rlv20502", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e39e8d8e-0d46-4628-94c5-07b594071e7e"}}}}, {"uuid": "7c12f6c5-55e6-49d1-bd94-2352ee3b1586", "name": "", "x": 38.65513908341776, "y": -122.34387958999741, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ac361065-6b3c-4ac6-96d5-9b474eb3b80f", "name": "p1rdt16638lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7c12f6c5-55e6-49d1-bd94-2352ee3b1586"}}}}, {"uuid": "0207b470-cf6d-4629-9b3c-ad531fda5dab", "name": "", "x": 38.655190554276075, "y": -122.34392111738993, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aa4eed95-33b7-4827-8744-52d14149b386", "name": "p1rlv38126", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0207b470-cf6d-4629-9b3c-ad531fda5dab"}}}}, {"uuid": "533bb500-770c-4d2c-9cc1-28775d01f44e", "name": "", "x": 38.65630824124314, "y": -122.34286109532569, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bae9a352-584d-4cf0-9ebd-eb280b684e78", "name": "p1rdt16725lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "533bb500-770c-4d2c-9cc1-28775d01f44e"}}}}, {"uuid": "ff5a7ad7-1d65-4c62-8ae0-267a310fb193", "name": "", "x": 38.65627492173817, "y": -122.34284238795301, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6cbb9976-253c-4863-899f-9218c4496688", "name": "p1rlv38269", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ff5a7ad7-1d65-4c62-8ae0-267a310fb193"}}}}, {"uuid": "f8eacce3-9525-4b06-8b1b-f7019fa7c45f", "name": "", "x": 38.62034621533613, "y": -122.43765627693834, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6bfb33cd-0cf1-455d-81e7-3d0472fa1b41", "name": "p1rdt8012", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f8eacce3-9525-4b06-8b1b-f7019fa7c45f"}}}}, {"uuid": "804049e0-ce7b-491e-99fa-e410e6a6a3be", "name": "", "x": 38.618246403950295, "y": -122.43508018831336, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e261b565-1f57-4cdc-bdd6-e045ee55d290", "name": "p1rdt7983", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "804049e0-ce7b-491e-99fa-e410e6a6a3be"}}}}, {"uuid": "6bfa5767-f2b2-4c1a-99b7-7b23d5fb2141", "name": "", "x": 38.620540310627334, "y": -122.43796845936235, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3f83d22a-fa1e-4a4e-aab9-a9dea8ee06e5", "name": "p1rdt8034", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6bfa5767-f2b2-4c1a-99b7-7b23d5fb2141"}}}}, {"uuid": "d27b544e-9687-455f-ba58-9ed436c5a572", "name": "", "x": 38.622378075951055, "y": -122.4397117047474, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "21e15d54-eab8-4204-9ed6-407fd8684700", "name": "p1rdt7954", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d27b544e-9687-455f-ba58-9ed436c5a572"}}}}, {"uuid": "81d253a0-1d96-4c57-8981-717e38dcce21", "name": "", "x": 38.62277584721677, "y": -122.43997282390552, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "016e4575-cd41-4993-be9b-5e5236a139ae", "name": "p1rdt7973", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "81d253a0-1d96-4c57-8981-717e38dcce21"}}}}, {"uuid": "4d3f203c-47be-4223-8720-2528ecc712e5", "name": "", "x": 38.62402950921016, "y": -122.44277403473237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ea481f8-b9c7-4067-9bfb-4f7cdc5dee15", "name": "p1rdt5172", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d3f203c-47be-4223-8720-2528ecc712e5"}}}}, {"uuid": "0e03e381-7790-4e61-94b7-9d458b302a4d", "name": "", "x": 38.62300895388021, "y": -122.44290656824234, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16712e10-4c7f-428b-917b-135ab3c2d4b3", "name": "p1rdt5155", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0e03e381-7790-4e61-94b7-9d458b302a4d"}}}}, {"uuid": "bf821b66-093f-4603-ad7e-32bed64b35bc", "name": "", "x": 38.623287659052096, "y": -122.4427643158668, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "afc636ed-f90c-4c48-822b-e86890d36f3b", "name": "p1rdt5155-p1rdt5172x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bf821b66-093f-4603-ad7e-32bed64b35bc"}}}}, {"uuid": "0363d42a-c376-4ae4-8b0d-bb484444fee6", "name": "", "x": 38.623116980624474, "y": -122.4447782161465, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9c289632-ba52-4b65-b6da-ac76b1477246", "name": "p1rdt5201", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0363d42a-c376-4ae4-8b0d-bb484444fee6"}}}}, {"uuid": "840097f5-3c7a-4849-b762-f137bdea4c16", "name": "", "x": 38.62329628881549, "y": -122.44457929911667, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ee606236-08d7-4258-96c9-e9104f15b467", "name": "p1rdt5159-p1rdt5201x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "840097f5-3c7a-4849-b762-f137bdea4c16"}}}}, {"uuid": "7f834bdd-4114-42ce-9e63-53bc785fec0a", "name": "", "x": 38.6234306387608, "y": -122.44440819183146, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "90fb2270-4759-4779-80c1-7f93d66e1c53", "name": "p1rdt5159", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7f834bdd-4114-42ce-9e63-53bc785fec0a"}}}}, {"uuid": "37141299-89a0-41ed-982a-51081d6b3d42", "name": "", "x": 38.62215863028796, "y": -122.44620579183537, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "86d3f96e-ffe2-459f-a2f1-b63d7bf138b8", "name": "p1rdt5180-p1rdt5201x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "37141299-89a0-41ed-982a-51081d6b3d42"}}}}, {"uuid": "6e4501c1-afa6-454f-bb4e-7186b7feb938", "name": "", "x": 38.615444643589946, "y": -122.4340993039006, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6fec8a81-a151-4d8f-adc7-6d6d87d7759f", "name": "p1rdt5923", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6e4501c1-afa6-454f-bb4e-7186b7feb938"}}}}, {"uuid": "da1cc01b-26a4-4326-b5b2-37141fb8691d", "name": "", "x": 38.61722132993687, "y": -122.42939704924423, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "14b429c3-41da-4123-b661-40cbdfaf33e0", "name": "p1rdt8346", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "da1cc01b-26a4-4326-b5b2-37141fb8691d"}}}}, {"uuid": "5a082e29-1507-4b02-b095-69b11f571dda", "name": "", "x": 38.617041139275344, "y": -122.43743292025952, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48e4b67a-0a47-48f0-b787-0a639db89caa", "name": "p1rdt7988", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5a082e29-1507-4b02-b095-69b11f571dda"}}}}, {"uuid": "4ed19a51-3310-41a4-aff9-28d8a46ca419", "name": "", "x": 38.62223049910566, "y": -122.44617598691588, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "893d2436-cd6c-40ad-90af-64ba1ac23f6e", "name": "p1rdt5180-p1rdt7988x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ed19a51-3310-41a4-aff9-28d8a46ca419"}}}}, {"uuid": "43402875-9dea-4473-be24-75b831aa6d6f", "name": "", "x": 38.62337315716766, "y": -122.45650688359399, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0089e5ea-d706-4a74-812f-654ae73eabcf", "name": "p1rdt8456", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "43402875-9dea-4473-be24-75b831aa6d6f"}}}}, {"uuid": "4cea5a72-5bb5-4f43-8eda-1ef360771178", "name": "", "x": 38.62156927448908, "y": -122.45679446794591, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "13b8cfc1-d8eb-4f47-b024-c1daacf3771d", "name": "p1rdt8447", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4cea5a72-5bb5-4f43-8eda-1ef360771178"}}}}, {"uuid": "cb3e167d-c2cb-4736-8f66-8143d56bd1cf", "name": "", "x": 38.6238198104542, "y": -122.456272029401, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "34054ef8-8942-4471-ac14-43c6a37e5a16", "name": "p1rdt8414-p1rdt8456x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb3e167d-c2cb-4736-8f66-8143d56bd1cf"}}}}, {"uuid": "8cb1f65f-d4fc-4d14-9857-6d98b2cc3094", "name": "", "x": 38.610218492856475, "y": -122.45635700104502, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8a53624b-8538-4cce-b588-c774875af31b", "name": "p1rdt6274", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8cb1f65f-d4fc-4d14-9857-6d98b2cc3094"}}}}, {"uuid": "fdc5de1c-ebb2-4bff-8945-795a93fc75f8", "name": "", "x": 38.61055108690851, "y": -122.4555659540378, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3ac93b23-1041-486e-a16e-861082c92f35", "name": "p1rdt6272-p1rdt6274x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fdc5de1c-ebb2-4bff-8945-795a93fc75f8"}}}}, {"uuid": "e57a56c3-8dcc-4aa1-91fc-48c8b8f06c8e", "name": "", "x": 38.610520720245056, "y": -122.45545884146962, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "034bda10-d48e-449c-9255-247cbf718683", "name": "p1rdt6272", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e57a56c3-8dcc-4aa1-91fc-48c8b8f06c8e"}}}}, {"uuid": "c16f990c-0ff1-414b-8380-ee7d791b0f96", "name": "", "x": 38.61197078011171, "y": -122.45741942756798, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0a75c5e2-2277-42b4-87d4-6eadff5c06f1", "name": "p1rdt6271", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c16f990c-0ff1-414b-8380-ee7d791b0f96"}}}}, {"uuid": "2dd1c6fe-9e94-4b4a-97e5-0fe2f1fb7e6d", "name": "", "x": 38.61207637689822, "y": -122.45737706222091, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "28954596-f060-4fa8-9f13-dfaa633bb739", "name": "p1rdt6270-p1rdt6271xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2dd1c6fe-9e94-4b4a-97e5-0fe2f1fb7e6d"}}}}, {"uuid": "0ca652d0-115a-441c-8eb8-5cf8c840706d", "name": "", "x": 38.6128563737481, "y": -122.45907473259327, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "898611f5-c343-4cca-8e5e-60cf0bfd796b", "name": "p1rdt6270-p1rdt6271xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0ca652d0-115a-441c-8eb8-5cf8c840706d"}}}}, {"uuid": "496b5d51-e112-464a-bb9c-4049894d8dee", "name": "", "x": 38.613028815797925, "y": -122.45946476660588, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b81bd5c2-96bb-445e-9eb8-d72360fd8a94", "name": "p1rdt6270-p1rdt6271xxxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "496b5d51-e112-464a-bb9c-4049894d8dee"}}}}, {"uuid": "d05a1a5c-0920-4097-babd-b5923ba0ddbd", "name": "", "x": 38.603726878082334, "y": -122.46288947925576, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "76f6a27f-0e4f-48b8-9dbd-31c6ffc4ec75", "name": "p1rdt7579", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d05a1a5c-0920-4097-babd-b5923ba0ddbd"}}}}, {"uuid": "417b978b-18e3-4121-a1bf-51f957cfd9dd", "name": "", "x": 38.60179587168076, "y": -122.46429351511154, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fa33ca9e-e16d-4c49-8a70-c6c30cf7b038", "name": "p1rdt7564", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "417b978b-18e3-4121-a1bf-51f957cfd9dd"}}}}, {"uuid": "38d20a1b-d399-4ab6-bf7c-aae66fa23a4c", "name": "", "x": 38.601539075146476, "y": -122.46251347070827, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8f2dabc2-0b52-490c-b13a-32c268f6bd33", "name": "p1rdt7588", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "38d20a1b-d399-4ab6-bf7c-aae66fa23a4c"}}}}, {"uuid": "4e241cc8-3082-4fd0-88d1-fc267588d21d", "name": "", "x": 38.60742474012847, "y": -122.4582846144434, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0f6de990-0988-4126-86ca-d1fd72c555fe", "name": "p1rdt7554", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4e241cc8-3082-4fd0-88d1-fc267588d21d"}}}}, {"uuid": "9b8ba534-6195-4b35-89f5-2a4c3c722bf4", "name": "", "x": 38.607801140709334, "y": -122.45761981019629, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2bdb2b51-0526-4995-bb5e-a2bd495488d4", "name": "p1rdt7554-p1rdt7570x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9b8ba534-6195-4b35-89f5-2a4c3c722bf4"}}}}, {"uuid": "4c45e384-de6e-47e6-a9ad-b6aae63c720c", "name": "", "x": 38.607753208324574, "y": -122.4554757397103, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f239ef4e-83f0-4a2c-ada3-8e30cef38472", "name": "p1rdt7559", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c45e384-de6e-47e6-a9ad-b6aae63c720c"}}}}, {"uuid": "3156fc94-96bd-4a53-b84b-3ddb7c65c545", "name": "", "x": 38.60740955675949, "y": -122.45440672587179, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ff343735-753a-48ca-92b1-ea778c9e0b5c", "name": "p1rdt7559-p1rdt8015x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3156fc94-96bd-4a53-b84b-3ddb7c65c545"}}}}, {"uuid": "e810c55c-bf24-40b9-8584-0ea6ba45bdd3", "name": "", "x": 38.60632927470628, "y": -122.45140187652409, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cc543f54-740b-4a7f-b1c5-eb3783a8ade0", "name": "p1rdt8015", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e810c55c-bf24-40b9-8584-0ea6ba45bdd3"}}}}, {"uuid": "7bf553bc-03a7-4134-b7e6-ce6194ed1aad", "name": "", "x": 38.60785880448065, "y": -122.45543337407624, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "09814176-7891-4fe1-addf-b47aa106c40d", "name": "p1rdt7559-p1rdt7570xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7bf553bc-03a7-4134-b7e6-ce6194ed1aad"}}}}, {"uuid": "2a3f447c-2df8-43bd-98a5-56059107b4e9", "name": "", "x": 38.607591729699735, "y": -122.45675980389136, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1dbec6c9-5c87-4f56-bd92-4a30d39ad094", "name": "p1rdt7559-p1rdt7570x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2a3f447c-2df8-43bd-98a5-56059107b4e9"}}}}, {"uuid": "3e452e28-6a28-4350-8544-cdbfbe2a921a", "name": "", "x": 38.601892868535366, "y": -122.45542862865831, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "db899c48-a801-4f83-b59d-e587ba80019d", "name": "p1rdt7552", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e452e28-6a28-4350-8544-cdbfbe2a921a"}}}}, {"uuid": "373ec05f-2d67-4736-8ebe-e41faea4f4ff", "name": "", "x": 38.60005814605219, "y": -122.4516448455036, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "93a5388e-ffd7-403e-b6cf-26b7e81feed1", "name": "p1rdt7986", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "373ec05f-2d67-4736-8ebe-e41faea4f4ff"}}}}, {"uuid": "fb5c1be3-22fd-4000-8e6b-267de4b40db1", "name": "", "x": 38.60314520391628, "y": -122.45852350850332, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2f0f3112-1395-48bf-88c1-8dd4b171478d", "name": "p1rdt7551", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fb5c1be3-22fd-4000-8e6b-267de4b40db1"}}}}, {"uuid": "928e2eec-1973-4044-bad0-d4fcdf464563", "name": "", "x": 38.60020849529689, "y": -122.46072753146206, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fc6bd64f-1ad3-4bd9-b590-7d4b673a94b5", "name": "p1rdt7561", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "928e2eec-1973-4044-bad0-d4fcdf464563"}}}}, {"uuid": "1741a3e1-3d98-4b45-9891-d9daf0f8513c", "name": "", "x": 38.60111102829196, "y": -122.46101936494843, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dead8520-e2f5-499b-9316-77780f9b1dfe", "name": "p1rdt7550", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1741a3e1-3d98-4b45-9891-d9daf0f8513c"}}}}, {"uuid": "af4f08f0-94de-4726-88ae-e00fcd4eaa36", "name": "", "x": 38.597594406004944, "y": -122.45741331498996, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f28de397-0db4-486a-8ce6-9f65c68703b3", "name": "p1rdt8434", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "af4f08f0-94de-4726-88ae-e00fcd4eaa36"}}}}, {"uuid": "45dc3818-21a6-4584-80fc-2019452cf93a", "name": "", "x": 38.597440760670644, "y": -122.45596586818255, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "184f95d4-cde1-4bf1-8a74-ebc7097cb10e", "name": "p1rdt8450", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "45dc3818-21a6-4584-80fc-2019452cf93a"}}}}, {"uuid": "799600d7-d852-4c9b-8f6e-1102fdded8ce", "name": "", "x": 38.597703329969455, "y": -122.45880555075607, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bbfe31b1-38ce-4ae4-9143-bf08c81617e8", "name": "p1rdt8440", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "799600d7-d852-4c9b-8f6e-1102fdded8ce"}}}}, {"uuid": "44c7d264-7191-4b9e-acb0-88e311db57b3", "name": "", "x": 38.59658206909063, "y": -122.45932321062192, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "516ca275-0d8e-4a9a-ab59-89cb66b95d93", "name": "p1rdt8436-p1rdt8440x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "44c7d264-7191-4b9e-acb0-88e311db57b3"}}}}, {"uuid": "9df146b4-516e-4ea5-bda7-c1a73ae15633", "name": "", "x": 38.59579222604902, "y": -122.46002037573007, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fcc42825-2690-4965-a99b-e78285a9b84e", "name": "p1rdt8436", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9df146b4-516e-4ea5-bda7-c1a73ae15633"}}}}, {"uuid": "c6913b29-d9ba-47a3-a192-1193e7e5403c", "name": "", "x": 38.596573779354905, "y": -122.45753186177956, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5f6e9b43-ceca-4a80-9569-696375a6ff5b", "name": "p1rdt8440-p1rdt8444x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c6913b29-d9ba-47a3-a192-1193e7e5403c"}}}}, {"uuid": "0a73aed7-d223-4038-9ac0-5b92a4d1987c", "name": "", "x": 38.5957635117617, "y": -122.45709408297363, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "685fbdbf-47af-4cc2-97ce-354dd04ce915", "name": "p1rdt8444", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a73aed7-d223-4038-9ac0-5b92a4d1987c"}}}}, {"uuid": "bf112380-b4c4-4738-a1d4-d798c1f01364", "name": "", "x": 38.599951855708426, "y": -122.46051919867074, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c0075333-98fe-4ee8-bb64-a18119b817c0", "name": "p1rdt7555", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bf112380-b4c4-4738-a1d4-d798c1f01364"}}}}, {"uuid": "f068e58c-2e16-4f15-8bf8-2f3eae98f96a", "name": "", "x": 38.601199336202434, "y": -122.46001207089114, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1e068b84-fbff-4546-b708-ca91ffe92b69", "name": "p1rdt7551-p1rdt7561x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f068e58c-2e16-4f15-8bf8-2f3eae98f96a"}}}}, {"uuid": "5cb7897b-26e3-4fb1-8110-0c2b58852939", "name": "", "x": 38.60649944562754, "y": -122.45751394231347, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1d8c14d0-8247-4a44-98c1-4534aa9037a2", "name": "p1rdt7551-p1rdt7574x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5cb7897b-26e3-4fb1-8110-0c2b58852939"}}}}, {"uuid": "7080975e-bc07-4286-ac0c-b487ce747aa8", "name": "", "x": 38.60635191905131, "y": -122.45581093557001, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ddf629eb-ea60-4fce-b731-7ebb33665829", "name": "p1rdt7553", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7080975e-bc07-4286-ac0c-b487ce747aa8"}}}}, {"uuid": "ece1113e-bcd2-4196-a2a1-14453f132e65", "name": "", "x": 38.606309626265485, "y": -122.45581243510644, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d4307e78-304a-4175-8e81-9cb23d99f394", "name": "p1rdt7572", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ece1113e-bcd2-4196-a2a1-14453f132e65"}}}}, {"uuid": "cbdc1d01-82c3-4ee4-babc-404553de25e5", "name": "", "x": 38.60642288565036, "y": -122.45576012137332, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f00dd033-8e7c-43af-bd16-1de2954e07be", "name": "p1rdt7553-p1rdt7574xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cbdc1d01-82c3-4ee4-babc-404553de25e5"}}}}, {"uuid": "c187bbb9-4399-4b90-a4f6-ea17d84c91b1", "name": "", "x": 38.60650133107034, "y": -122.45676802538416, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7744d8d9-73a8-4274-9c91-5542620942f5", "name": "p1rdt7553-p1rdt7574x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c187bbb9-4399-4b90-a4f6-ea17d84c91b1"}}}}, {"uuid": "e6eab6d5-ecec-4a44-9135-ace4449f9a3f", "name": "", "x": 38.616823684704634, "y": -122.45485169561282, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a9722136-480b-44cb-8b0e-0b3165712688", "name": "p1rdt5179-p1rdt6273x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e6eab6d5-ecec-4a44-9135-ace4449f9a3f"}}}}, {"uuid": "cbcad839-30cf-45d7-8aeb-5541d365147b", "name": "", "x": 38.61884536658003, "y": -122.45181991735679, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d22f1247-b756-4498-8cf8-fef7d1e859ff", "name": "p1rdt5179", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cbcad839-30cf-45d7-8aeb-5541d365147b"}}}}, {"uuid": "32980d01-7147-4efb-9208-6924bc7a6c36", "name": "", "x": 38.620392420969665, "y": -122.45625723062152, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "28af960e-6f27-483a-8029-0c5f1641f51d", "name": "p1rdt8408", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "32980d01-7147-4efb-9208-6924bc7a6c36"}}}}, {"uuid": "6eb63711-311c-48b0-a200-7708a569b3be", "name": "", "x": 38.62105939691115, "y": -122.45567255802798, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "433162b1-2a9b-4187-ba28-ec57503d76f6", "name": "p1rdt8458", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6eb63711-311c-48b0-a200-7708a569b3be"}}}}, {"uuid": "34790c46-d3a6-4ef4-a144-f8aa7791f306", "name": "", "x": 38.61794197262064, "y": -122.4571451861387, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "07f340ca-58c2-4331-8265-a39a45c87b75", "name": "p1rdt8439", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "34790c46-d3a6-4ef4-a144-f8aa7791f306"}}}}, {"uuid": "2882cbbd-35ac-40a5-8eba-2fa1353c5ab1", "name": "", "x": 38.619657499896064, "y": -122.45651946734527, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3430524c-820d-4f17-ba1b-377aeef4bbcd", "name": "p1rdt8408-p1rdt8439x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2882cbbd-35ac-40a5-8eba-2fa1353c5ab1"}}}}, {"uuid": "950056a4-f77d-43ed-abc8-f0ebb5f1eacf", "name": "", "x": 38.61643197384722, "y": -122.45750913060422, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "19d5304c-574f-4646-8095-d2dcbbea86e7", "name": "p1rdt6278-p1rdt8439x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "950056a4-f77d-43ed-abc8-f0ebb5f1eacf"}}}}, {"uuid": "46372221-c5d6-4e25-9937-70ae8e4a5744", "name": "", "x": 38.61757719949048, "y": -122.46073569903709, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a8c69243-872f-4e25-9d03-82692bbf8779", "name": "p1rdt8405-p1rdt8445x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "46372221-c5d6-4e25-9937-70ae8e4a5744"}}}}, {"uuid": "0193f084-2414-465f-8507-c518ab5551df", "name": "", "x": 38.61750461268671, "y": -122.46257773961285, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1e3ecdca-4b27-4a9d-8599-637924e86602", "name": "p1rdt8405-p1rdt8445xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0193f084-2414-465f-8507-c518ab5551df"}}}}, {"uuid": "559151e0-4417-49f0-a82d-3d35634b96df", "name": "", "x": 38.61747453032813, "y": -122.46077804087776, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bc0ee90f-1f9e-435e-bac4-86a4688c48fc", "name": "p1rdt8445", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "559151e0-4417-49f0-a82d-3d35634b96df"}}}}, {"uuid": "bd56f243-69e2-4d25-88e4-d5062a621ab9", "name": "", "x": 38.58085055283345, "y": -122.50956971443162, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bf648a0d-3262-4150-892b-55c3b117050a", "name": "p1rdt6500-p1rdt6519xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bd56f243-69e2-4d25-88e4-d5062a621ab9"}}}}, {"uuid": "4f978e8c-71c9-4108-8bd4-dd7e04c67d03", "name": "", "x": 38.58085769734513, "y": -122.50951590453553, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5789c3b2-eb91-4e4c-85e8-24f5893e1a2c", "name": "p1rdt6500-p1rdt6519xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4f978e8c-71c9-4108-8bd4-dd7e04c67d03"}}}}, {"uuid": "1a89ad58-99e8-48ca-b84d-4d30890fd198", "name": "", "x": 38.580324139975936, "y": -122.51120115232804, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c0824c21-244b-4d4e-85d6-238ac4908b5a", "name": "p1rdt6505-p1rdt6508x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1a89ad58-99e8-48ca-b84d-4d30890fd198"}}}}, {"uuid": "a9ea404f-0da3-492e-ad2b-10b63708892f", "name": "", "x": 38.57943061458019, "y": -122.51076650882104, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eb1c1e50-902d-443d-8c9a-b728d2f6b6f1", "name": "p1rdt6505", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a9ea404f-0da3-492e-ad2b-10b63708892f"}}}}, {"uuid": "845aaad9-1218-47c7-8b04-b96551dfcf6b", "name": "", "x": 38.57967511307611, "y": -122.5126018254279, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "66b7b2e9-7658-4de0-8197-3829c6179353", "name": "p1rdt6510-p1rdt6523x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "845aaad9-1218-47c7-8b04-b96551dfcf6b"}}}}, {"uuid": "0aa3f3d5-e5aa-42de-9954-8117a443544a", "name": "", "x": 38.57908668009848, "y": -122.5112130456528, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "848c04de-e4d5-4520-9dce-0073776c2ae4", "name": "p1rdt6510", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0aa3f3d5-e5aa-42de-9954-8117a443544a"}}}}, {"uuid": "80fce609-371e-4216-a76f-a73c72f53ba1", "name": "", "x": 38.57473976942866, "y": -122.51780959626444, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e07d8bc1-2f8a-4067-a2a7-b903dd042ce3", "name": "p1rdt5730-p1rdt9479x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "80fce609-371e-4216-a76f-a73c72f53ba1"}}}}, {"uuid": "ae73743c-8548-4137-a180-59f6280b9424", "name": "", "x": 38.57217576563056, "y": -122.51803280458198, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d5897bb2-1f72-4aeb-9090-74e2411b5786", "name": "p1rdt5730", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ae73743c-8548-4137-a180-59f6280b9424"}}}}, {"uuid": "ae5a3785-7653-4bf5-8675-35a3db35f092", "name": "", "x": 38.5747498946316, "y": -122.51790816237944, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e7f9286b-4209-402a-a365-1d27da4efb75", "name": "p1rdt5840-p1rdt9479x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ae5a3785-7653-4bf5-8675-35a3db35f092"}}}}, {"uuid": "693261a2-e33f-420e-98d7-aba12afe2b54", "name": "", "x": 38.57341254858641, "y": -122.51993371906103, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35722d90-049e-4c67-9654-acce0572e6c2", "name": "p1rdt5840", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "693261a2-e33f-420e-98d7-aba12afe2b54"}}}}, {"uuid": "a649e8d5-4a5d-4cc5-af0e-8100bd84e39b", "name": "", "x": 38.576726073438714, "y": -122.52446579115181, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "61ba1001-8b9d-481c-b205-45c6e0beadc1", "name": "p1rdt9298", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a649e8d5-4a5d-4cc5-af0e-8100bd84e39b"}}}}, {"uuid": "5ef16793-c098-41e2-b98c-4f9e4e7eefc7", "name": "", "x": 38.576522299104546, "y": -122.52532815241987, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f4a41fe9-62ce-45ba-abcd-086ba429baa0", "name": "p1rdt9302", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ef16793-c098-41e2-b98c-4f9e4e7eefc7"}}}}, {"uuid": "1dc016b2-4413-4089-9171-3916a1d89cab", "name": "", "x": 38.57714443025326, "y": -122.52236567259841, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3035d22c-c39f-4f07-9fe9-29888b16057d", "name": "p1rdt9310", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1dc016b2-4413-4089-9171-3916a1d89cab"}}}}, {"uuid": "b7ae5a8f-66ef-4d60-9134-78c031712321", "name": "", "x": 38.57657358147667, "y": -122.51940754990198, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "644c5887-31f1-436c-bbf6-dae5a70743a2", "name": "p1rdt9316", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b7ae5a8f-66ef-4d60-9134-78c031712321"}}}}, {"uuid": "8efefa1d-8ecd-4c4d-9e24-01b27035c531", "name": "", "x": 38.57940200391493, "y": -122.5212830170439, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b8721684-5439-482c-b8e5-be330d3cf745", "name": "p1rdt9312", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8efefa1d-8ecd-4c4d-9e24-01b27035c531"}}}}, {"uuid": "f194676e-4380-4328-ab02-daf91a9df474", "name": "", "x": 38.57641631447873, "y": -122.5192328534116, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7011f1dc-1e7d-4961-9a23-620b7f5737af", "name": "p1rdt9311", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f194676e-4380-4328-ab02-daf91a9df474"}}}}, {"uuid": "b9a6ab8a-47b8-4813-b138-81c932fd688f", "name": "", "x": 38.57548870286482, "y": -122.51882223524302, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "95d939ff-e20d-42b3-bb88-f1975f9fa0aa", "name": "p1rdt6518-p1rdt9311x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b9a6ab8a-47b8-4813-b138-81c932fd688f"}}}}, {"uuid": "659d0d06-e371-4b97-a79c-b5e43f8c7802", "name": "", "x": 38.56957251351933, "y": -122.5146506475286, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "77d2122b-cbb7-4844-bbb2-55e939431e50", "name": "p1rdt5729", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "659d0d06-e371-4b97-a79c-b5e43f8c7802"}}}}, {"uuid": "491c68dc-d6da-48bf-ae44-2d31c3d9cc06", "name": "", "x": 38.569500663957065, "y": -122.51470628390435, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "52f308f4-35db-49ec-a599-f8380489f952", "name": "p1rdt5729-p1rdt5731x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "491c68dc-d6da-48bf-ae44-2d31c3d9cc06"}}}}, {"uuid": "73967e47-18f3-483a-b10a-771124b63d48", "name": "", "x": 38.56683955344907, "y": -122.51476612858174, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "95cd61cf-f1cb-4af2-9d3b-e42978642003", "name": "p1rdt5731", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "73967e47-18f3-483a-b10a-771124b63d48"}}}}, {"uuid": "c7c257cd-2ea4-4e0e-9bb1-7f376fac96bf", "name": "", "x": 38.57065927664959, "y": -122.51444197635051, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b55c58cf-153e-4aa3-b099-8a1db05a6ae5", "name": "p1rdt5728", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c7c257cd-2ea4-4e0e-9bb1-7f376fac96bf"}}}}, {"uuid": "8ca253b4-42a5-4f7b-a94f-f26b95862d14", "name": "", "x": 38.57561216943165, "y": -122.51516613679155, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "66ef2ffb-e67d-47eb-ae59-194c538ab861", "name": "p1rdt5728-p1rdt6537x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8ca253b4-42a5-4f7b-a94f-f26b95862d14"}}}}, {"uuid": "34dad3c6-ccba-4a06-b54f-a9247d0f4c5f", "name": "", "x": 38.579768071852676, "y": -122.5141439807202, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9b5695dd-714e-4de1-a63a-f142ff0460e1", "name": "p1rdt9468", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "34dad3c6-ccba-4a06-b54f-a9247d0f4c5f"}}}}, {"uuid": "90fe05b7-f3d0-4489-a2c8-35e8cb9c8b41", "name": "", "x": 38.58086149565407, "y": -122.51897714369541, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e6348d4-7fcb-4546-af84-8ece75b6332f", "name": "p1rdt6502", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "90fe05b7-f3d0-4489-a2c8-35e8cb9c8b41"}}}}, {"uuid": "24c5be44-0224-48e1-b290-3d4953eec426", "name": "", "x": 38.580154407405615, "y": -122.51201736754072, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ddfa01c0-4d12-4f96-ab50-0082ef9914a6", "name": "p1rdt6501-p1rdt9468x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "24c5be44-0224-48e1-b290-3d4953eec426"}}}}, {"uuid": "93db63be-461c-4dab-8933-25baf8c11b03", "name": "", "x": 38.58045994181232, "y": -122.51074519698878, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7e4fd2ed-daa1-4a22-936f-8d51ee928d99", "name": "p1rdt6501-p1rdt9468x_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "93db63be-461c-4dab-8933-25baf8c11b03"}}}}, {"uuid": "10535ec6-eb7b-492e-a01d-5671139f021b", "name": "", "x": 38.58028290845341, "y": -122.51146113028999, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "42f09ae1-037a-4565-9cd2-0187c45b7866", "name": "p1rdt6509-p1rdt6514x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10535ec6-eb7b-492e-a01d-5671139f021b"}}}}, {"uuid": "0679c775-bf98-4471-bcd1-d965416cb97f", "name": "", "x": 38.580317644679276, "y": -122.51149205289134, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0737f6ec-0d5d-4cff-b4b7-9910c7076984", "name": "p1rdt6514", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0679c775-bf98-4471-bcd1-d965416cb97f"}}}}, {"uuid": "ecc88ed7-fb40-4552-8972-44bc465197f2", "name": "", "x": 38.57914402812339, "y": -122.51052209118085, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60b93cd6-c9fc-46ef-8b37-6b14d0773df6", "name": "p1rdt6498-p1rdt6516x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ecc88ed7-fb40-4552-8972-44bc465197f2"}}}}, {"uuid": "36242e7c-2807-441f-bc4d-826953103893", "name": "", "x": 38.578899383271626, "y": -122.51078551451845, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f5c5466f-b7e4-4844-967b-9e8b11c68b44", "name": "p1rdt6498", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "36242e7c-2807-441f-bc4d-826953103893"}}}}, {"uuid": "0317cab2-2dea-4ee4-9adb-5d6193ef7f1b", "name": "", "x": 38.566808328998086, "y": -122.50026076244916, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1f6ad7d-f7ea-4b94-956c-ec4a3b2028d5", "name": "p1rdt7298-p1rdt7313x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0317cab2-2dea-4ee4-9adb-5d6193ef7f1b"}}}}, {"uuid": "7eb6d4fd-b3a0-4a74-bd1c-256d42ed5872", "name": "", "x": 38.56643827491598, "y": -122.50011683345299, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b658bf21-450c-4e6b-9dec-c5023a05fd19", "name": "p1rdt7298", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7eb6d4fd-b3a0-4a74-bd1c-256d42ed5872"}}}}, {"uuid": "a581d35a-62ba-4b17-881e-badaf252f4fd", "name": "", "x": 38.56306630294141, "y": -122.50758361380268, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "28d17238-8db8-41da-960c-317183423576", "name": "p1rdt7036-p1rdt7091xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a581d35a-62ba-4b17-881e-badaf252f4fd"}}}}, {"uuid": "52b1a853-b828-4e73-b319-cc93eab563e6", "name": "", "x": 38.56354447960164, "y": -122.50839891620973, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "770cf0ab-50f1-489b-b2ea-d23ba186d10b", "name": "p1rdt7036-p1rdt7091x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "52b1a853-b828-4e73-b319-cc93eab563e6"}}}}, {"uuid": "54e92f2f-4588-4cda-9b5f-6f20e3c81165", "name": "", "x": 38.56300711787946, "y": -122.50763349737177, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "52068090-b613-46d7-a31f-ad3ca26382d5", "name": "p1rdt7036", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "54e92f2f-4588-4cda-9b5f-6f20e3c81165"}}}}, {"uuid": "3a0dbb41-c169-4ec0-8293-06ea239c1640", "name": "", "x": 38.562803482644604, "y": -122.51371079164413, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "97be7ac3-a710-4de8-a666-276813582cd6", "name": "p1rdt7620", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3a0dbb41-c169-4ec0-8293-06ea239c1640"}}}}, {"uuid": "b5ba243f-bb48-42fc-9d16-bfcab7c4716d", "name": "", "x": 38.56262386822574, "y": -122.51386121629318, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5bddd75e-1974-41ee-ab51-625c7485a573", "name": "p1rdt7627", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b5ba243f-bb48-42fc-9d16-bfcab7c4716d"}}}}, {"uuid": "e16bdb71-55c9-4a8f-8864-3327a56f5392", "name": "", "x": 38.56326190620687, "y": -122.51262082119965, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b3a4dfb4-e1b3-43b9-ae42-b0cec47ff4ad", "name": "p1rdt7311", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e16bdb71-55c9-4a8f-8864-3327a56f5392"}}}}, {"uuid": "4837ebc1-7a64-454a-95d7-ad5dc94def01", "name": "", "x": 38.56382004055108, "y": -122.51327924731947, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e4d8bafa-711d-4fd7-8374-7eeaeb43edcd", "name": "p1rdt9473", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4837ebc1-7a64-454a-95d7-ad5dc94def01"}}}}, {"uuid": "d1d35578-3675-44f4-b9e5-3512fa60f90f", "name": "", "x": 38.56294875123604, "y": -122.51180445263074, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "607c7275-da9a-4620-b019-59a66e98c2e6", "name": "p1rdt7306", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1d35578-3675-44f4-b9e5-3512fa60f90f"}}}}, {"uuid": "aa3b4b1d-2dd2-46e6-b28d-96be15961943", "name": "", "x": 38.5622926191724, "y": -122.5122220982717, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "56d67e3e-46af-4e2c-86a8-191d97b0ce8a", "name": "p1rdt7626", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aa3b4b1d-2dd2-46e6-b28d-96be15961943"}}}}, {"uuid": "8d521c86-54cb-4653-b5c6-8d9cae9e2cb8", "name": "", "x": 38.56302679357027, "y": -122.51026940176808, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3a65c4d3-2fc6-48c8-b944-68c4229db3dd", "name": "p1rdt7302", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8d521c86-54cb-4653-b5c6-8d9cae9e2cb8"}}}}, {"uuid": "a9e57660-7319-4bfc-a3d2-fcf715fdcfa9", "name": "", "x": 38.56309662911135, "y": -122.5097294573527, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "01c9d31d-c3bb-4950-9bbd-00377c252ddc", "name": "p1rdt7617", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a9e57660-7319-4bfc-a3d2-fcf715fdcfa9"}}}}, {"uuid": "c255184c-f2ed-4139-8383-2022a4b54427", "name": "", "x": 38.56316201817732, "y": -122.50953508538782, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a11cf3d9-90bb-4de8-b637-6ec9128525ec", "name": "p1rdt7617-p1rdt7625x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c255184c-f2ed-4139-8383-2022a4b54427"}}}}, {"uuid": "467d86b5-04a7-4310-966c-b874fd20f77e", "name": "", "x": 38.56129645031688, "y": -122.51025818859465, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "723e2b5c-414c-4f3d-ba23-d2df4bc63e75", "name": "p1rdt7630", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "467d86b5-04a7-4310-966c-b874fd20f77e"}}}}, {"uuid": "6edb6e11-ef87-458b-9e88-98c9e94188dc", "name": "", "x": 38.56190962697, "y": -122.51114576371964, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c7167a2e-9e83-441e-a15b-0256848c3f6d", "name": "p1rdt7616", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6edb6e11-ef87-458b-9e88-98c9e94188dc"}}}}, {"uuid": "b03f4ed4-9c9d-4423-9868-5308cb6b1368", "name": "", "x": 38.56171870357492, "y": -122.50994542040628, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aa48cf27-3b07-4460-ad9c-8d9862238645", "name": "p1rdt7621", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b03f4ed4-9c9d-4423-9868-5308cb6b1368"}}}}, {"uuid": "f92f9ef8-f56e-4f46-aa51-c53171f745c3", "name": "", "x": 38.56318612934499, "y": -122.50945665578503, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "53df7b6e-bd8c-43f2-860d-8869aec5d079", "name": "p1rdt7621-p1rdt7625x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f92f9ef8-f56e-4f46-aa51-c53171f745c3"}}}}, {"uuid": "7cf7bb6c-4bb7-464a-be3a-91cd2396461f", "name": "", "x": 38.55823465883282, "y": -122.50730279853406, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "08d3a02a-555d-4ad1-9b13-d413b7a16eef", "name": "p1rdt7090", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7cf7bb6c-4bb7-464a-be3a-91cd2396461f"}}}}, {"uuid": "3cc41f38-ab18-423e-8f7c-520e94039dcb", "name": "", "x": 38.558375802568776, "y": -122.50792515178091, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3cf406b-69e6-4aee-a6fc-272dad7693a4", "name": "p1rdt7054", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3cc41f38-ab18-423e-8f7c-520e94039dcb"}}}}, {"uuid": "685168bc-7964-448d-9c19-26d528fd2eae", "name": "", "x": 38.55914097308907, "y": -122.50637841432136, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aae22557-7d34-401d-82c9-2d2710ff2915", "name": "p1rdt7069", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "685168bc-7964-448d-9c19-26d528fd2eae"}}}}, {"uuid": "cfab6ae3-c499-4fe4-bd80-17d2c1ba2a07", "name": "", "x": 38.55990008450235, "y": -122.50687823607828, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f614382d-3883-4f6b-b1f6-c8e83d84ee22", "name": "p1rdt7087", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cfab6ae3-c499-4fe4-bd80-17d2c1ba2a07"}}}}, {"uuid": "73e43a9d-07db-47c1-94a1-988b0a844d27", "name": "", "x": 38.561212075777895, "y": -122.50733192344723, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8cebb186-4d9e-4d2c-b0d9-100056d34942", "name": "p1rdt7075", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "73e43a9d-07db-47c1-94a1-988b0a844d27"}}}}, {"uuid": "e987d9bf-0536-4244-9f47-a482bed25baa", "name": "", "x": 38.56134985808187, "y": -122.50795078492914, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "662e2a1c-9a54-4ac3-b478-98e3a478349d", "name": "p1rdt7080", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e987d9bf-0536-4244-9f47-a482bed25baa"}}}}, {"uuid": "db51b889-2677-4f16-9c3d-ee199f25a1a3", "name": "", "x": 38.56137014768056, "y": -122.50849010412762, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "161d6f3b-8bd9-4fa8-9442-c6ff008e8d3d", "name": "p1rdt7619", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "db51b889-2677-4f16-9c3d-ee199f25a1a3"}}}}, {"uuid": "c1c279b4-65c1-4732-a079-66f1aa2a03a9", "name": "", "x": 38.56077220663575, "y": -122.5085365470598, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "105df8ff-ec38-4cd6-b557-c318b4023bd0", "name": "p1rdt7615", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c1c279b4-65c1-4732-a079-66f1aa2a03a9"}}}}, {"uuid": "f337a156-4901-495b-b237-6edff9890775", "name": "", "x": 38.561738481750105, "y": -122.50901203752454, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b9e53141-a773-4127-9558-3887070a8f36", "name": "p1rdt7631", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f337a156-4901-495b-b237-6edff9890775"}}}}, {"uuid": "5ffbe342-0944-4873-987b-e7b8ca04bcbb", "name": "", "x": 38.56310083575031, "y": -122.50950410932236, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "460f5de9-8d4f-468a-b67a-b3b05354a9ce", "name": "p1rdt7625-p1rdt7631x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ffbe342-0944-4873-987b-e7b8ca04bcbb"}}}}, {"uuid": "4a433241-8ed9-4429-92a8-1ce38f0ba622", "name": "", "x": 38.5810553987312, "y": -122.5094376679452, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fec078c2-a5d8-4317-a8ac-bc25772f6358", "name": "p1rdt6515-p1rdt6535xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4a433241-8ed9-4429-92a8-1ce38f0ba622"}}}}, {"uuid": "d74595fc-2533-48bd-a6b5-323641953b72", "name": "", "x": 38.58105426448104, "y": -122.50949283188041, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f5a05d0e-8cf2-4ab8-bdfd-24b8cd12ad67", "name": "p1rdt6515-p1rdt6535xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d74595fc-2533-48bd-a6b5-323641953b72"}}}}, {"uuid": "5e32b2a0-a40b-4f7a-b599-26082e03f999", "name": "", "x": 38.58100676420751, "y": -122.50921942626415, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "04c1e05a-9cbb-4e53-9412-1cffd3976bed", "name": "p1rdt6515-p1rdt6536xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5e32b2a0-a40b-4f7a-b599-26082e03f999"}}}}, {"uuid": "f6d2dfe0-3d18-4c2c-b520-52cbb246dd08", "name": "", "x": 38.58098452673457, "y": -122.50917228702704, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5aa6899b-19a2-41e6-b445-f9fe2536c8d9", "name": "p1rdt6515-p1rdt6536xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f6d2dfe0-3d18-4c2c-b520-52cbb246dd08"}}}}, {"uuid": "995470a2-9f55-4576-97e3-0af02bcc170b", "name": "", "x": 38.58182522217373, "y": -122.50873063816502, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d21061fa-1011-44f7-8a20-26fcf0550f52", "name": "p1rdt8901-p1rdt8902x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "995470a2-9f55-4576-97e3-0af02bcc170b"}}}}, {"uuid": "1974122e-33d7-4966-a35c-5e21f25bdbb4", "name": "", "x": 38.581260006183335, "y": -122.50726033751013, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f23ab51c-56f3-4421-b66e-7cdcf109787d", "name": "p1rdt8901", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1974122e-33d7-4966-a35c-5e21f25bdbb4"}}}}, {"uuid": "6a6c8e90-6c34-4143-ae2d-51c7114ee9e2", "name": "", "x": 38.589021563154894, "y": -122.51711477621102, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "61972a50-ce24-4ec1-8535-402665b55a55", "name": "p1rdt9377", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a6c8e90-6c34-4143-ae2d-51c7114ee9e2"}}}}, {"uuid": "007ab400-5c36-4d26-ae49-7a6f16f74ac6", "name": "", "x": 38.58692523202436, "y": -122.52017146759988, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "84200441-4c26-4966-a4b7-6b91fb43f02e", "name": "p1rdt7301", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "007ab400-5c36-4d26-ae49-7a6f16f74ac6"}}}}, {"uuid": "bffa8083-006e-415c-b5d9-eb6a34928792", "name": "", "x": 38.581769930879894, "y": -122.50871878720857, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "43c862de-b014-4b24-8b34-54dae6edcf5a", "name": "p1rdt8902-p1rdt9377x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bffa8083-006e-415c-b5d9-eb6a34928792"}}}}, {"uuid": "de4f5afd-459e-4cbf-aa49-cd504cb83abb", "name": "", "x": 38.5814032621987, "y": -122.50967321866453, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32e86968-974e-4bcc-b562-1d4209771cf0", "name": "p1rdt8902-p1rdt9377x_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "de4f5afd-459e-4cbf-aa49-cd504cb83abb"}}}}, {"uuid": "6a742844-a654-453e-919e-80445d759442", "name": "", "x": 38.59300712782786, "y": -122.52139582849708, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "37c41a4b-e439-42a1-b9a7-0582c528f0e5", "name": "p1rdt8490", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a742844-a654-453e-919e-80445d759442"}}}}, {"uuid": "b6439b84-94cd-405b-b7ee-069f0c9d898c", "name": "", "x": 38.59104960383041, "y": -122.5215908683816, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "271ab023-4425-40d8-8080-2481c71309b5", "name": "p1rdt9463", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b6439b84-94cd-405b-b7ee-069f0c9d898c"}}}}, {"uuid": "39925f06-fa1e-450f-95b8-ba4e101482e4", "name": "", "x": 38.59323212584656, "y": -122.52027519448441, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "307d9c6d-d5ee-4490-95d3-5a9b1d171e54", "name": "p1rdt8492", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "39925f06-fa1e-450f-95b8-ba4e101482e4"}}}}, {"uuid": "39bd7fbf-764d-4497-aaba-76a78b273ff5", "name": "", "x": 38.59334183117795, "y": -122.52026098011822, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "605c34bc-3f7c-4eb7-8df0-fcd00d261921", "name": "p1rdt7599-p1rdt8492x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "39bd7fbf-764d-4497-aaba-76a78b273ff5"}}}}, {"uuid": "f5319190-a0b2-4d37-9550-a0f2b572bf96", "name": "", "x": 38.59572620360423, "y": -122.50628475874987, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3833996b-287c-4a13-9e7c-6834047f3691", "name": "p1rdt7599-p1rdt8492xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5319190-a0b2-4d37-9550-a0f2b572bf96"}}}}, {"uuid": "f38d56e1-87e0-41f8-b63c-a5019038e230", "name": "", "x": 38.60515752123577, "y": -122.47345444080051, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7f6d3fab-3b83-40c9-85c4-cfeddd0d317a", "name": "p1rdt6226-p1rdt9333xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f38d56e1-87e0-41f8-b63c-a5019038e230"}}}}, {"uuid": "7d2b8e82-3663-4e48-9e89-e8e528cc8114", "name": "", "x": 38.60491485090167, "y": -122.474443511017, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "76f24b35-1b82-4760-9817-80c166073f37", "name": "p1rdt6226-p1rdt9333x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7d2b8e82-3663-4e48-9e89-e8e528cc8114"}}}}, {"uuid": "68343b22-8902-4816-b01b-158043d770b3", "name": "", "x": 38.60439463477556, "y": -122.4756262540049, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d81fc6d7-3400-41d4-91d7-b350d7def98d", "name": "p1rdt6226", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "68343b22-8902-4816-b01b-158043d770b3"}}}}, {"uuid": "4f54bf78-ef0f-44fc-9eab-cf069c5c976f", "name": "", "x": 38.572765543379965, "y": -122.49283903354065, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "36c3c493-ff68-4bb8-a3f4-043c5f847bd3", "name": "p1rdt5650-p1rdt5662x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4f54bf78-ef0f-44fc-9eab-cf069c5c976f"}}}}, {"uuid": "a982988a-244f-4f1c-aac3-e1f1824ffd2c", "name": "", "x": 38.57146366361991, "y": -122.49011602390345, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c8f1c67e-9e29-45a3-a2a3-c2f3493a6898", "name": "p1rdt5650", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a982988a-244f-4f1c-aac3-e1f1824ffd2c"}}}}, {"uuid": "1f15fd9f-5dec-450c-985a-6838f958d682", "name": "", "x": 38.566867108561745, "y": -122.49714650199947, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "81f0e00e-bc49-448a-8e69-0569ed6a8c1a", "name": "p1rdt5658-p1rdt5663x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1f15fd9f-5dec-450c-985a-6838f958d682"}}}}, {"uuid": "f75a053a-7d19-4d97-a68d-be7390bb27ae", "name": "", "x": 38.56722225496197, "y": -122.49589645931059, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e67d07fb-aec5-4120-8254-32bfcd91e378", "name": "p1rdt5658-p1rdt5663xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f75a053a-7d19-4d97-a68d-be7390bb27ae"}}}}, {"uuid": "2fa9bd24-74db-46e1-9028-ab707e76db9d", "name": "", "x": 38.56676442477756, "y": -122.497188761547, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7356d982-36fd-46cb-9300-8889502e8dc8", "name": "p1rdt5663", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2fa9bd24-74db-46e1-9028-ab707e76db9d"}}}}, {"uuid": "825e0b55-7892-413f-9b90-fe1673ed473f", "name": "", "x": 38.563115754357725, "y": -122.50436551560664, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b470fa62-70d4-4cc5-8f7e-b9cda37481e0", "name": "p1rdt7067", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "825e0b55-7892-413f-9b90-fe1673ed473f"}}}}, {"uuid": "a92aaa91-6e7b-4ef0-9c9b-44040d044206", "name": "", "x": 38.562327045687596, "y": -122.50539247201371, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9bb8596a-bcb2-4282-bf1b-9939a9af87d9", "name": "p1rdt7046", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a92aaa91-6e7b-4ef0-9c9b-44040d044206"}}}}, {"uuid": "08c625af-eec7-4383-83b2-1f963a0cd6e9", "name": "", "x": 38.56260404120564, "y": -122.50270471808909, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fb3a9847-70d0-4004-95ef-63884c6c1cdc", "name": "p1rdt7038", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "08c625af-eec7-4383-83b2-1f963a0cd6e9"}}}}, {"uuid": "aeaaaaea-e526-430b-9d4a-421fafdb5bad", "name": "", "x": 38.562387612025795, "y": -122.4991118756889, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ac6e8ccf-75ec-42e0-a3cb-9ab86e2731a4", "name": "p1rdt7070", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aeaaaaea-e526-430b-9d4a-421fafdb5bad"}}}}, {"uuid": "635cd087-1d7c-47b3-b8a7-fec348f9b62f", "name": "", "x": 38.56242616294009, "y": -122.5018066922163, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e9cb2d8d-1991-463c-9e6b-88f5624f28c3", "name": "p1rdt7038-p1rdt7070x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "635cd087-1d7c-47b3-b8a7-fec348f9b62f"}}}}, {"uuid": "bcf8098e-ebef-4e7d-a388-84e59af95fb8", "name": "", "x": 38.55588435346, "y": -122.5067067908326, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0a597011-5e60-46fe-90d6-85728ff0ffa3", "name": "p1rdt9396", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bcf8098e-ebef-4e7d-a388-84e59af95fb8"}}}}, {"uuid": "09a7dcb1-00b7-4ecb-a625-2d5c4eed9235", "name": "", "x": 38.55491482364518, "y": -122.50783397819646, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b5791345-57dc-4f54-ab54-ea63e6a54ee0", "name": "p1rdt9381", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "09a7dcb1-00b7-4ecb-a625-2d5c4eed9235"}}}}, {"uuid": "53098f16-a96d-4396-ad7d-244d0c2c5f88", "name": "", "x": 38.557265355979126, "y": -122.50588266860625, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ac70c13b-5f4f-45f3-880a-b4b476ea552a", "name": "p1rdt7088", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "53098f16-a96d-4396-ad7d-244d0c2c5f88"}}}}, {"uuid": "c3e8351c-dd1c-4e18-b0d2-d7247c861a1f", "name": "", "x": 38.55764619612384, "y": -122.50520475670933, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "31cd4834-477f-4060-8efd-0504c8e8eaa9", "name": "p1rdt7089", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c3e8351c-dd1c-4e18-b0d2-d7247c861a1f"}}}}, {"uuid": "d29fd631-620d-43b6-846e-6fbd7db41afb", "name": "", "x": 38.55961566604152, "y": -122.50276328297903, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75947ffd-3765-443b-bef8-b6af746ef624", "name": "p1rdt7061", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d29fd631-620d-43b6-846e-6fbd7db41afb"}}}}, {"uuid": "81184bc6-d55f-4e11-abb5-4dbf0edbf6ab", "name": "", "x": 38.55890205970878, "y": -122.50382809113916, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "324f5d62-9feb-4fe4-bc1b-3dcf01898148", "name": "p1rdt7061-p1rdt7089x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "81184bc6-d55f-4e11-abb5-4dbf0edbf6ab"}}}}, {"uuid": "d9a8273a-d0fb-452e-b442-66d402d6ecf2", "name": "", "x": 38.560425566891645, "y": -122.50182050287499, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "84578de8-d5de-41fe-b637-42425e97b7db", "name": "p1rdt7061-p1rdt7070x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d9a8273a-d0fb-452e-b442-66d402d6ecf2"}}}}, {"uuid": "adff7086-5c4d-4692-ab27-39fd2c9e06e3", "name": "", "x": 38.56719749877506, "y": -122.49557460649763, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "02407b52-58c3-403c-9b5b-38695f435476", "name": "p1rdt5658-p1rdt7070x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "adff7086-5c4d-4692-ab27-39fd2c9e06e3"}}}}, {"uuid": "f380a6bd-42ac-4e94-852b-71eb43d521f4", "name": "", "x": 38.58873407774302, "y": -122.47343765394794, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c0843e99-e917-473c-bec7-ee0c3ddec601", "name": "p1rdt5017-p1rdt5200x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f380a6bd-42ac-4e94-852b-71eb43d521f4"}}}}, {"uuid": "21b5d83a-8c2e-4161-94a0-5316a279921c", "name": "", "x": 38.58804691015901, "y": -122.47096337199758, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "799ab435-c0a4-4515-8125-e8ca2fb7632d", "name": "p1rdt5200", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "21b5d83a-8c2e-4161-94a0-5316a279921c"}}}}, {"uuid": "44f794c1-8e6e-4411-a416-500797f57171", "name": "", "x": 38.599124013036686, "y": -122.46398556528375, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1b28595b-dcbe-4d1b-92c4-94acf370bb1f", "name": "p1rdt7576", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "44f794c1-8e6e-4411-a416-500797f57171"}}}}, {"uuid": "59b6cf59-ca9a-4f11-a6e9-118bc61c0fc8", "name": "", "x": 38.59899175164701, "y": -122.4633858496211, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4ce65512-7d5f-4514-b55c-1775e80dd94d", "name": "p1rdt8422", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59b6cf59-ca9a-4f11-a6e9-118bc61c0fc8"}}}}, {"uuid": "036c8efd-7db2-4870-82f2-3b943df50d82", "name": "", "x": 38.59980734698757, "y": -122.46809510052073, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75a31fa2-4df8-418a-a215-d0d450ced9a3", "name": "p1rdt7576-p1rdt8151xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "036c8efd-7db2-4870-82f2-3b943df50d82"}}}}, {"uuid": "5ddda534-1bae-4376-9940-923ffa5b0268", "name": "", "x": 38.59985029320267, "y": -122.46810315325398, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "df71ab4b-258c-4812-9537-6d425bacb468", "name": "p1rdt7576-p1rdt8151xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ddda534-1bae-4376-9940-923ffa5b0268"}}}}, {"uuid": "a77eb685-3722-4073-b5e1-fe119b376547", "name": "", "x": 38.59989292024887, "y": -122.46810581013978, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c951cf67-3297-407f-805c-55d9c03fb519", "name": "p1rdt7576-p1rdt8151x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a77eb685-3722-4073-b5e1-fe119b376547"}}}}, {"uuid": "63cc9012-4b26-4a85-b7cd-a17d2b412999", "name": "", "x": 38.59895094748302, "y": -122.46820159887727, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1613a53e-5194-4d26-b83b-475d9f02a32c", "name": "p1rdt8155", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "63cc9012-4b26-4a85-b7cd-a17d2b412999"}}}}, {"uuid": "e1bf1831-29fd-4c8c-a2d8-2caca097b732", "name": "", "x": 38.59895213180579, "y": -122.4682554984801, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b706c56-20f1-49ed-9cbe-0ec1491b83e0", "name": "p1rdt8149", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e1bf1831-29fd-4c8c-a2d8-2caca097b732"}}}}, {"uuid": "67b4a3bb-1120-4c1f-a699-5860c8fa90eb", "name": "", "x": 38.5924677842981, "y": -122.4635262800833, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8b423745-cc70-4c3a-adb0-f648170b4ab1", "name": "p1rdt8441", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "67b4a3bb-1120-4c1f-a699-5860c8fa90eb"}}}}, {"uuid": "a3ed93a5-c0ba-4cc1-ae05-71fcbd30574b", "name": "", "x": 38.59106375235361, "y": -122.46454322086704, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dac2cb8c-428b-49c4-8368-35608c050390", "name": "p1rdt5153-p1rdt8441xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a3ed93a5-c0ba-4cc1-ae05-71fcbd30574b"}}}}, {"uuid": "f0f6cd73-360a-4152-8fca-73066c995f16", "name": "", "x": 38.5891703292866, "y": -122.46631406470807, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dff898c1-a386-4219-9e8d-2d08b49f9098", "name": "p1rdt5153-p1rdt8441x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f0f6cd73-360a-4152-8fca-73066c995f16"}}}}, {"uuid": "0293898d-b01c-4468-ab99-40e98ee44971", "name": "", "x": 38.58821580644588, "y": -122.46709794144316, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eb8dae66-287a-4b8a-9cda-6ae02cb8f8a9", "name": "p1rdt5153", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0293898d-b01c-4468-ab99-40e98ee44971"}}}}, {"uuid": "94f325f3-6d2a-45bc-908f-e3cea41f7886", "name": "", "x": 38.59865977452597, "y": -122.46691737157991, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "78081763-07d2-4989-b492-e1c5178c4097", "name": "p1rdt8150", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "94f325f3-6d2a-45bc-908f-e3cea41f7886"}}}}, {"uuid": "fb3cd9d4-237f-4530-bd9a-6177b42a039b", "name": "", "x": 38.59382920785335, "y": -122.46428153625678, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "83b76782-be09-4733-a35c-6f3f26059a4d", "name": "p1rdt8150-p1rdt8441x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fb3cd9d4-237f-4530-bd9a-6177b42a039b"}}}}, {"uuid": "ba950250-6005-4961-ba68-6eea3fdd90dd", "name": "", "x": 38.59741418959317, "y": -122.46389890047125, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f2ef098d-d7e6-4530-a5cc-b6472ec9ffdc", "name": "p1rdt8150-p1rdt8442x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ba950250-6005-4961-ba68-6eea3fdd90dd"}}}}, {"uuid": "2202743d-a855-497a-87e1-851058c746c5", "name": "", "x": 38.597632581049226, "y": -122.46353019233372, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f6700763-e6dc-4626-ac2b-22985f0043be", "name": "p1rdt8442", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2202743d-a855-497a-87e1-851058c746c5"}}}}, {"uuid": "105d022a-345a-4dc1-add4-903d032442f7", "name": "", "x": 38.59878207629303, "y": -122.46742572315105, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b7280d1f-5ff9-45ee-9949-ecc70509a2a1", "name": "p1rdt8150-p1rdt8155x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "105d022a-345a-4dc1-add4-903d032442f7"}}}}, {"uuid": "358f69b2-02c9-48c0-8e3a-5a7b150a456d", "name": "", "x": 38.59899028699417, "y": -122.46961983252689, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9a30e197-897f-4516-b4e5-f70081e6f8c7", "name": "p1rdt8157", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "358f69b2-02c9-48c0-8e3a-5a7b150a456d"}}}}, {"uuid": "ae0a5a8f-0550-45d5-af05-1ee69e000ba1", "name": "", "x": 38.59975154279307, "y": -122.4680237146737, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b0a6628e-afc1-4daf-8a29-7626ac2aa5dd", "name": "p1rdt8151-p1rdt8155x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ae0a5a8f-0550-45d5-af05-1ee69e000ba1"}}}}, {"uuid": "2f1aa61f-7af2-40d3-b303-0f0bc8d88847", "name": "", "x": 38.64164273016234, "y": -122.45541248693772, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f903015c-95a7-4d6e-b2a5-e9705c050c6e", "name": "p1rdt5483", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2f1aa61f-7af2-40d3-b303-0f0bc8d88847"}}}}, {"uuid": "273a046e-c5ce-4125-9e31-028bb8292c8c", "name": "", "x": 38.64024304330955, "y": -122.45644844030662, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d29d8b74-a24d-4474-9752-c1ffa1aa7f7c", "name": "p1rdt5481", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "273a046e-c5ce-4125-9e31-028bb8292c8c"}}}}, {"uuid": "68c9a036-808f-4fad-8506-4a7896b8996d", "name": "", "x": 38.641756332042426, "y": -122.45557875811565, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2568f11c-8a37-4a55-8bce-9f0d56ac386a", "name": "p1rdt5480", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "68c9a036-808f-4fad-8506-4a7896b8996d"}}}}, {"uuid": "6a9bbaf7-c083-4fc4-802d-91e2d4b0f4db", "name": "", "x": 38.642142868875986, "y": -122.45608936956037, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a7d7f462-1ab5-4fd8-baaa-7e576eead5c7", "name": "p1rdt5477", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a9bbaf7-c083-4fc4-802d-91e2d4b0f4db"}}}}, {"uuid": "33ece59e-3a10-4c95-950d-ecedcc29e1d0", "name": "", "x": 38.64281235221596, "y": -122.45532194437911, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "df1d5615-4a0b-4041-8940-f13de9f7036a", "name": "p1rdt5477-p1rdt7201x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "33ece59e-3a10-4c95-950d-ecedcc29e1d0"}}}}, {"uuid": "000a5153-68d8-45da-89ab-617a8cd6cb36", "name": "", "x": 38.64321277078752, "y": -122.4548323247065, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f64ed4a2-6afb-447c-8c6b-15935e050a6d", "name": "p1rdt7201", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "000a5153-68d8-45da-89ab-617a8cd6cb36"}}}}, {"uuid": "f7c432d6-1633-4358-86dc-895b71dd2c40", "name": "", "x": 38.642219786001824, "y": -122.45774171841002, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a8c3f7f-b9be-4c5e-b6f0-8f2fc18935fa", "name": "p1rdt5472", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f7c432d6-1633-4358-86dc-895b71dd2c40"}}}}, {"uuid": "d7d5b93b-1a5a-4f71-95e8-3f2b1a9a411b", "name": "", "x": 38.64221051314406, "y": -122.45768209005053, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "595463a5-2019-4c94-b72d-c824c2aef347", "name": "p1rdt5472-p1rdt5477x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d7d5b93b-1a5a-4f71-95e8-3f2b1a9a411b"}}}}, {"uuid": "0d4453f9-bd03-4074-82f5-92e6944000d8", "name": "", "x": 38.63937777553964, "y": -122.46168143344667, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d69527e6-70b6-43e2-8b9e-7c8570ad5ddf", "name": "p1rdt5472-p1rdt5476x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0d4453f9-bd03-4074-82f5-92e6944000d8"}}}}, {"uuid": "7c7cf273-8a35-4f1b-b0df-652e02e8d7c4", "name": "", "x": 38.634273490971374, "y": -122.45107406346328, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "02ea9067-6a2a-48b6-b5f1-10992b9fbd77", "name": "p1rdt7704", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7c7cf273-8a35-4f1b-b0df-652e02e8d7c4"}}}}, {"uuid": "7f99c451-b1c2-40d3-9f37-2911f14e0083", "name": "", "x": 38.633218038007875, "y": -122.44832866649233, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f633393e-4d67-4646-838b-14f25641b426", "name": "p1rdt7704-p1rdt9266x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7f99c451-b1c2-40d3-9f37-2911f14e0083"}}}}, {"uuid": "983285a7-75f5-4a80-b562-57390f24885f", "name": "", "x": 38.63351410324478, "y": -122.44695962318366, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6fbb2bd0-d109-4248-85f3-266fe479677f", "name": "p1rdt9266", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "983285a7-75f5-4a80-b562-57390f24885f"}}}}, {"uuid": "91a6b8b3-39c6-43fb-9476-f82b581450b9", "name": "", "x": 38.63645110302719, "y": -122.45301866057562, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4462b9c6-748f-48e9-9ff9-7f20a06cf456", "name": "p1rdt7712", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "91a6b8b3-39c6-43fb-9476-f82b581450b9"}}}}, {"uuid": "c6e2115c-5e23-404f-8d02-cfc7459bceb4", "name": "", "x": 38.63434015287993, "y": -122.45255214689988, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "048e2bab-67f2-4975-81a1-bbc9f2f9cd88", "name": "p1rdt7718", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c6e2115c-5e23-404f-8d02-cfc7459bceb4"}}}}, {"uuid": "b8a68cb6-346c-42b7-abe2-6eed14ab959d", "name": "", "x": 38.636858070821944, "y": -122.45332579295936, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "74968ebc-53c5-4fc6-8172-3ffa9dea7683", "name": "p1rdt7701", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b8a68cb6-346c-42b7-abe2-6eed14ab959d"}}}}, {"uuid": "a9d37e1d-5173-4635-a52b-7cf55ef8c650", "name": "", "x": 38.63763391930191, "y": -122.4535037389147, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ec849ee4-3d69-46a9-9a2a-242a3943e46c", "name": "p1rdt7699", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a9d37e1d-5173-4635-a52b-7cf55ef8c650"}}}}, {"uuid": "4260e8f1-7798-4deb-9e31-1fca3abf1a52", "name": "", "x": 38.63933239277819, "y": -122.45585430535672, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3cfb3a23-3a93-4d89-8b70-e4730ebbce1a", "name": "p1rdt5485", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4260e8f1-7798-4deb-9e31-1fca3abf1a52"}}}}, {"uuid": "bc656b69-36a4-43ff-b71d-c180a2f08d8e", "name": "", "x": 38.638463291461264, "y": -122.45417138292237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "890cd47a-994b-4dca-8d59-25164f04c927", "name": "p1rdt5485-p1rdt7699x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bc656b69-36a4-43ff-b71d-c180a2f08d8e"}}}}, {"uuid": "6a726f29-4815-4b7e-9cdd-3ba9cab41478", "name": "", "x": 38.639561691754864, "y": -122.45649160162748, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2b9e57e0-6dc8-4831-ac7d-36f8608b7a8d", "name": "p1rdt5475", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a726f29-4815-4b7e-9cdd-3ba9cab41478"}}}}, {"uuid": "ea984b77-b138-4d35-84e2-6f5e1b3be68a", "name": "", "x": 38.63942177536906, "y": -122.46162651516015, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ae343ca3-3337-4528-b117-38a51e6d023f", "name": "p1rdt5475-p1rdt5476x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea984b77-b138-4d35-84e2-6f5e1b3be68a"}}}}, {"uuid": "c6a41314-ff2d-43b3-b5cc-6e2a28deffa6", "name": "", "x": 38.63947133387594, "y": -122.46167250985621, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4c977e6c-43f0-4d7e-b19f-82f0de97dab2", "name": "p1rdt5476-p1rdt5478x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c6a41314-ff2d-43b3-b5cc-6e2a28deffa6"}}}}, {"uuid": "4979c1e5-b450-4e65-96a4-18e6717e9de6", "name": "", "x": 38.637232713702204, "y": -122.4583095586275, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9a97491e-2c98-4584-9b74-5593f17faeda", "name": "p1rdt5478", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4979c1e5-b450-4e65-96a4-18e6717e9de6"}}}}, {"uuid": "2eb92f32-3756-41cd-b0da-65a66c24a381", "name": "", "x": 38.629275148712736, "y": -122.45440586693407, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "96399e51-1243-4e7f-ae3a-5e2c67123aae", "name": "p1rdt6848", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2eb92f32-3756-41cd-b0da-65a66c24a381"}}}}, {"uuid": "02d00be7-cb00-4607-bd85-777ce7f0a710", "name": "", "x": 38.62915793743979, "y": -122.45307010539497, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2b764d22-debb-4d88-8221-ff79307e609f", "name": "p1rdt6848-p1rdt9264x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "02d00be7-cb00-4607-bd85-777ce7f0a710"}}}}, {"uuid": "2777bf8f-fb4b-4519-88c5-7462abde8f9a", "name": "", "x": 38.62929755153899, "y": -122.45269743640755, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6bdf3994-bb0c-44f4-b1ea-ab29e73bd39c", "name": "p1rdt9264", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2777bf8f-fb4b-4519-88c5-7462abde8f9a"}}}}, {"uuid": "d6f76c08-aa28-4f37-96e7-37ad79f4b724", "name": "", "x": 38.63204510201893, "y": -122.46437683506844, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3e92b102-eaee-41cc-a2fc-c6c4b3bfb58b", "name": "p1rdt6847", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d6f76c08-aa28-4f37-96e7-37ad79f4b724"}}}}, {"uuid": "597d61bf-b7a2-48d5-9bb2-6befc99d855a", "name": "", "x": 38.637551036439916, "y": -122.4658407872937, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be9350ab-7ad2-4a89-a374-94bf69588d7f", "name": "p1rdt6847-p1rdt7624x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "597d61bf-b7a2-48d5-9bb2-6befc99d855a"}}}}, {"uuid": "854252b7-a9be-439b-b237-47caad78812a", "name": "", "x": 38.63745413036962, "y": -122.41088901665674, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4d6c5b78-35c4-475a-8837-776dea236c95", "name": "p1rdt6348", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "854252b7-a9be-439b-b237-47caad78812a"}}}}, {"uuid": "601cbd90-802e-4147-93e4-1a0dee2ea031", "name": "", "x": 38.63621334895868, "y": -122.41023104176281, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c935f1c0-e36c-407d-a2e8-4181c4b0733e", "name": "p1rdt6350", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "601cbd90-802e-4147-93e4-1a0dee2ea031"}}}}, {"uuid": "e5e50d5c-d080-4d8d-b9cf-869a003ee1f5", "name": "", "x": 38.635943272929005, "y": -122.41464349224492, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "40280da5-767c-4610-b6a8-ff411e1c33e8", "name": "p1rdt6345", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e5e50d5c-d080-4d8d-b9cf-869a003ee1f5"}}}}, {"uuid": "2fb72ea7-b013-493a-940f-9e1e8a973dd2", "name": "", "x": 38.637135599334236, "y": -122.41985198242058, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1bdfc1ac-98a4-43dd-bb2c-837d0a2c15f9", "name": "p1rdt6356", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2fb72ea7-b013-493a-940f-9e1e8a973dd2"}}}}, {"uuid": "65123f8f-99b8-4bc5-a743-806f7f6963d0", "name": "", "x": 38.63428208141972, "y": -122.41685332058216, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8e51e0d9-24b6-40ac-859a-51ea74c93e76", "name": "p1rdt6353", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65123f8f-99b8-4bc5-a743-806f7f6963d0"}}}}, {"uuid": "ad2a38c2-3edd-4b63-9187-242b9e02e7b1", "name": "", "x": 38.637037161169054, "y": -122.41998840936154, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2040b1a2-85bc-405a-9dab-138561b5e3ac", "name": "p1rdt6354-p1rdt6356x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ad2a38c2-3edd-4b63-9187-242b9e02e7b1"}}}}, {"uuid": "3be1ed3b-9da6-42c9-8228-52e392d086e4", "name": "", "x": 38.6365030259924, "y": -122.42074352091329, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1a05e7c9-4bff-46fd-b356-8120b481b053", "name": "p1rdt6354", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3be1ed3b-9da6-42c9-8228-52e392d086e4"}}}}, {"uuid": "150904ad-1522-4a28-9697-1c2bfb036cd7", "name": "", "x": 38.63888731873398, "y": -122.42664972566449, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c7166849-6ecd-4270-bf52-d0579838336a", "name": "p1rdt6347", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "150904ad-1522-4a28-9697-1c2bfb036cd7"}}}}, {"uuid": "4d009f86-5794-4639-91c0-2a5ac3e6cdce", "name": "", "x": 38.63046949482658, "y": -122.42586839274048, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6e36f1f1-6993-46b0-bafa-9530fd1652ef", "name": "p1rdt7605", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d009f86-5794-4639-91c0-2a5ac3e6cdce"}}}}, {"uuid": "4ae5dbc6-e0bc-49e8-b304-6f7ac9362bd2", "name": "", "x": 38.63106444152601, "y": -122.42668905474402, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f95e5fa5-a84c-42a4-b519-8d344e816ecd", "name": "p1rdt7598", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ae5dbc6-e0bc-49e8-b304-6f7ac9362bd2"}}}}, {"uuid": "a5f8fa10-b048-48a1-860f-3b120eb360fa", "name": "", "x": 38.632704736208574, "y": -122.42169322012252, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5f9809eb-41e0-40a8-b43a-93556f767f68", "name": "p1rdt7589", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a5f8fa10-b048-48a1-860f-3b120eb360fa"}}}}, {"uuid": "0ce8819e-f17b-461b-8c62-5afbaabea831", "name": "", "x": 38.62803766509506, "y": -122.4206605617657, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3410d88a-3e9c-427e-a79e-5c602455ed1d", "name": "p1rdt7612", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0ce8819e-f17b-461b-8c62-5afbaabea831"}}}}, {"uuid": "5d59340d-16c5-4b89-8091-5c32f734632c", "name": "", "x": 38.64794018977543, "y": -122.44170447330542, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6163371c-55ef-4900-a3ef-2e4e8fc2894a", "name": "p1rdt6347-p1rdt8470x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5d59340d-16c5-4b89-8091-5c32f734632c"}}}}, {"uuid": "1965718d-a8b3-400b-a48b-dcee8657a6ac", "name": "", "x": 38.65468732876317, "y": -122.39725551743196, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "769c14db-ac3f-438d-9f7d-c7eb2d3074b5", "name": "p1rdt5653", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1965718d-a8b3-400b-a48b-dcee8657a6ac"}}}}, {"uuid": "29c6209f-ca61-4fb8-987f-c2da46ad0d9b", "name": "", "x": 38.65539216836069, "y": -122.39642965058673, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "98f2c16a-cdbd-49a3-b60d-4be6e9158480", "name": "p1rdt5218-p1rdt5653x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "29c6209f-ca61-4fb8-987f-c2da46ad0d9b"}}}}, {"uuid": "9ccf40bd-2c7a-40e1-a90b-72438700a78e", "name": "", "x": 38.65638553565669, "y": -122.3958356267157, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9dda7f7c-3b21-46a0-88a3-2b7f028b7772", "name": "p1rdt5218", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9ccf40bd-2c7a-40e1-a90b-72438700a78e"}}}}, {"uuid": "c08bee5c-777a-4666-8eec-9b3dd673bfbc", "name": "", "x": 38.649267204221246, "y": -122.40284351830519, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "58c6d858-d457-4fe6-a45b-b9b2b73cad8c", "name": "p1rdt5195", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c08bee5c-777a-4666-8eec-9b3dd673bfbc"}}}}, {"uuid": "f1105e91-4b0f-4530-adf0-ed1cb33735f5", "name": "", "x": 38.649760224171196, "y": -122.40177465588245, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fbc486eb-4f08-4602-a101-1298d4a46b32", "name": "p1rdt5195_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f1105e91-4b0f-4530-adf0-ed1cb33735f5"}}}}, {"uuid": "49651b45-fc27-43ca-af8d-9789a4a6004a", "name": "", "x": 38.648493079669315, "y": -122.39370880076001, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3741c9d4-d03a-4b2f-be57-52a8977351ad", "name": "p1rdt6995", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "49651b45-fc27-43ca-af8d-9789a4a6004a"}}}}, {"uuid": "4b0305c0-1037-4ef4-949a-597397ef270e", "name": "", "x": 38.648911595375175, "y": -122.39447297420028, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2d4d11a9-8de3-4dbe-8974-6005ed40f363", "name": "p1rdt6995-p1rdt7015x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4b0305c0-1037-4ef4-949a-597397ef270e"}}}}, {"uuid": "a7bc3009-8e8d-4e17-b616-c76252626a6c", "name": "", "x": 38.64914243697819, "y": -122.39455192500522, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6278a0d-f5d3-4b11-aee9-3bb23f9954a8", "name": "p1rdt7015", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a7bc3009-8e8d-4e17-b616-c76252626a6c"}}}}, {"uuid": "abb1e08a-855e-4897-a673-308816a942cc", "name": "", "x": 38.65509732869403, "y": -122.34387202316023, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6c0d417e-c787-4b0a-a39e-b19ef274b36b", "name": "p1rdt16638", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "abb1e08a-855e-4897-a673-308816a942cc"}}}}, {"uuid": "8297b428-5b23-4152-ab9c-87c2979a4b24", "name": "", "x": 38.656349996019614, "y": -122.34286866169235, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c2d0eb0b-bbb6-4b3e-bdc6-4c8a0e7d466f", "name": "p1rdt16725", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8297b428-5b23-4152-ab9c-87c2979a4b24"}}}}, {"uuid": "9a600806-0174-49eb-91db-fe69ef61fe1b", "name": "", "x": 38.65481285259022, "y": -122.34567144468134, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ddb8e50b-2619-4e74-aee6-84dc4e11389e", "name": "p1rdt16638-p1rdt6995x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9a600806-0174-49eb-91db-fe69ef61fe1b"}}}}, {"uuid": "39e782d2-a807-49ed-80d0-94565d915d21", "name": "", "x": 38.649657570740004, "y": -122.40108599864732, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9056795d-5c81-4fb9-96bc-51d63b32b187", "name": "p1rdt5195-p1rdt6995x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "39e782d2-a807-49ed-80d0-94565d915d21"}}}}, {"uuid": "cd10cffe-a98a-4acd-b67f-fc34e733b7f8", "name": "", "x": 38.647538844802774, "y": -122.40874594362695, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "227d848c-cddc-4561-996b-f8f7a60a5a89", "name": "p1rdt5195-p1rdt5202xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cd10cffe-a98a-4acd-b67f-fc34e733b7f8"}}}}, {"uuid": "089f2e83-3db8-4d79-9106-f2ded1bf5cc7", "name": "", "x": 38.64780415928914, "y": -122.40698510373619, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "43e1b69a-c6dd-447e-82d9-921998de9837", "name": "p1rdt5195-p1rdt5202xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "089f2e83-3db8-4d79-9106-f2ded1bf5cc7"}}}}, {"uuid": "26852e48-00b2-4987-9615-bb92ddc4d19d", "name": "", "x": 38.64819471408059, "y": -122.40580973948633, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8e2f2704-4dee-4c78-b199-256b907156f3", "name": "p1rdt5195-p1rdt5202x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "26852e48-00b2-4987-9615-bb92ddc4d19d"}}}}, {"uuid": "5ce2d535-677f-4124-97e4-ce80c6f3a10b", "name": "", "x": 38.64756484598567, "y": -122.4087885476493, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "97e4f179-9d60-4183-8326-eb0ab98a53eb", "name": "p1rdt5202", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ce2d535-677f-4124-97e4-ce80c6f3a10b"}}}}, {"uuid": "2e5194ca-81e3-4cce-b22d-e2f1ba68986d", "name": "", "x": 38.646212863621486, "y": -122.4077336633597, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "17fedb14-6008-43fd-b7e9-342a113f27a6", "name": "p1rdt5202-p1rdt5206x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2e5194ca-81e3-4cce-b22d-e2f1ba68986d"}}}}, {"uuid": "87956ea9-4e14-4028-a086-a242d4767471", "name": "", "x": 38.64569758673296, "y": -122.40751541256846, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2ed081eb-6b56-43b8-9cf8-e7ffdd8222f2", "name": "p1rdt5206", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "87956ea9-4e14-4028-a086-a242d4767471"}}}}, {"uuid": "f78d39fc-8180-40e0-b698-65cd5bfa44c7", "name": "", "x": 38.65086417573999, "y": -122.42606190704704, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a21680f1-33a7-44e1-9293-98c6861ba2a5", "name": "p1rdt7268", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f78d39fc-8180-40e0-b698-65cd5bfa44c7"}}}}, {"uuid": "70e977d3-80cc-4570-8493-adcde3e97600", "name": "", "x": 38.64877414711051, "y": -122.41168870941135, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6e61d2f-f75e-4335-aec9-4722942be9f1", "name": "p1rdt5202-p1rdt7268x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "70e977d3-80cc-4570-8493-adcde3e97600"}}}}, {"uuid": "72701ad2-e31a-4773-8b69-a2d3ae194283", "name": "", "x": 38.64212986886906, "y": -122.42144512012567, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "88cc1382-6b14-4500-8a21-662fce6a0c0b", "name": "p1rdt6355", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "72701ad2-e31a-4773-8b69-a2d3ae194283"}}}}, {"uuid": "c0ec56eb-72c0-4ca6-8556-375e1b1f7cc1", "name": "", "x": 38.64194634219145, "y": -122.4207801394437, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3c1edcfa-e0e4-4493-a9bb-e6033185ce67", "name": "p1rdt6349", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c0ec56eb-72c0-4ca6-8556-375e1b1f7cc1"}}}}, {"uuid": "bf893988-405e-4ab8-b905-b745f43a9a00", "name": "", "x": 38.64540330832493, "y": -122.421204010774, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eeab7dfa-540c-4275-b159-f6ac4d1350f9", "name": "p1rdt7224", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bf893988-405e-4ab8-b905-b745f43a9a00"}}}}, {"uuid": "a6dbd015-0a15-482b-9236-103a366e1112", "name": "", "x": 38.64637376282259, "y": -122.41881749796097, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b0fef9b3-a4bd-421c-8a54-cbf6f44c460d", "name": "p1rdt7618", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a6dbd015-0a15-482b-9236-103a366e1112"}}}}, {"uuid": "4c5c6dcd-63b8-41a2-8093-8cca2d72aeea", "name": "", "x": 38.649069267013274, "y": -122.42574072103456, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "22978d10-c9dc-4c84-8025-5749c730daa6", "name": "p1rdt7224-p1rdt7268x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c5c6dcd-63b8-41a2-8093-8cca2d72aeea"}}}}, {"uuid": "c46f4e0b-dc3c-4a3f-be3f-38e560bf6190", "name": "", "x": 38.64786537466463, "y": -122.44168489363972, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6225b33-2abc-4f77-9d65-459794f56353", "name": "p1rdt7268-p1rdt8470x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c46f4e0b-dc3c-4a3f-be3f-38e560bf6190"}}}}, {"uuid": "927a4063-4d22-46e6-ac4f-c015458ef7d8", "name": "", "x": 38.65324099971405, "y": -122.46490061193234, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "97198258-8ba3-4950-8747-3241c6a4fcee", "name": "p1rdt7790", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "927a4063-4d22-46e6-ac4f-c015458ef7d8"}}}}, {"uuid": "8f7b0799-74df-4334-8e29-dd46150745c8", "name": "", "x": 38.65493103663836, "y": -122.46522487253812, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "62078787-3ae2-47b3-8f67-8e89e110c8be", "name": "p1rdt7735", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8f7b0799-74df-4334-8e29-dd46150745c8"}}}}, {"uuid": "d818e1c1-0ba9-41c1-a9de-6fd225be8ae4", "name": "", "x": 38.651340821800964, "y": -122.4634244039528, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "15a7847f-aa96-4206-b4c6-422802f4e0a6", "name": "p1rdt7790-p1rdt9090x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d818e1c1-0ba9-41c1-a9de-6fd225be8ae4"}}}}, {"uuid": "fb91d7f3-340f-4966-b7e0-d358967a4734", "name": "", "x": 38.65962472553894, "y": -122.44176628998517, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "26613f51-86bf-4ae1-86c0-f23e48cf606e", "name": "p1rdt8911", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fb91d7f3-340f-4966-b7e0-d358967a4734"}}}}, {"uuid": "1bab182c-4582-47c6-8d17-29842e513a82", "name": "", "x": 38.65931212124818, "y": -122.44176119733557, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7bc7d623-3ca7-4c4e-b11c-f373e90d06b6", "name": "p1rdt8911-p1rdt9384x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1bab182c-4582-47c6-8d17-29842e513a82"}}}}, {"uuid": "b5c3aa09-2214-445c-bfa5-3d3f96eb953f", "name": "", "x": 38.65864576551388, "y": -122.44127613204223, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6eb9c7a5-5ab1-4d9b-a59e-538b68ad0bb9", "name": "p1rdt9384", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b5c3aa09-2214-445c-bfa5-3d3f96eb953f"}}}}, {"uuid": "92919a40-4844-490d-a018-5e9680adcac0", "name": "", "x": 38.660983681991716, "y": -122.44208551181131, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "924fc042-6ddc-484b-b09f-c65b35817d25", "name": "p1rdt8905", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "92919a40-4844-490d-a018-5e9680adcac0"}}}}, {"uuid": "b8032e4e-ca80-4e94-918c-c9de73f29a0c", "name": "", "x": 38.66020225533911, "y": -122.44026057728638, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "adcc33f8-72a3-434c-a021-6c5973713a91", "name": "p1rdt8916", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b8032e4e-ca80-4e94-918c-c9de73f29a0c"}}}}, {"uuid": "1df05fd9-2ce1-423d-a9c2-c03c77b85391", "name": "", "x": 38.66014117583918, "y": -122.43986982074505, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5584edfb-c31e-4e1d-87d3-b8161a59b15b", "name": "p1rdt8904-p1rdt8916x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1df05fd9-2ce1-423d-a9c2-c03c77b85391"}}}}, {"uuid": "822ecf5e-9bf8-48d7-ae80-9241a08d5eef", "name": "", "x": 38.659870600443035, "y": -122.43853470846769, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2edd17c2-6dfb-4f86-8998-b90a99755e96", "name": "p1rdt8904", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "822ecf5e-9bf8-48d7-ae80-9241a08d5eef"}}}}, {"uuid": "cfdaa503-512b-4f4b-b7d2-25964bd60174", "name": "", "x": 38.66173047874001, "y": -122.44241135887862, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "361385c6-bb6d-4bbc-ab7d-4a5774e03d82", "name": "p1rdt8915", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cfdaa503-512b-4f4b-b7d2-25964bd60174"}}}}, {"uuid": "e09dc659-3e15-4f79-91c9-b52d623601ea", "name": "", "x": 38.66056980039024, "y": -122.44983541740483, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25a9ec20-35b9-4262-a02d-cafa63e5ee42", "name": "p1rdt6574", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e09dc659-3e15-4f79-91c9-b52d623601ea"}}}}, {"uuid": "17b20f9d-2e67-45af-a1f1-f14bdf5b6629", "name": "", "x": 38.66134287929267, "y": -122.44811296163041, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c9ef9958-5d9e-4907-91cd-4c5d099daaf1", "name": "p1rdt6574-p1rdt8915x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "17b20f9d-2e67-45af-a1f1-f14bdf5b6629"}}}}, {"uuid": "c909eedd-a3ad-4f87-a346-40647f90f3ca", "name": "", "x": 38.65937095205677, "y": -122.45169503023163, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "599c6ed9-5ff7-4c97-a469-adceecaaf902", "name": "p1rdt6581", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c909eedd-a3ad-4f87-a346-40647f90f3ca"}}}}, {"uuid": "169793d1-b20d-4e43-a918-a31b39feffe4", "name": "", "x": 38.658524104486, "y": -122.45387735426675, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6114624f-81c8-4d9c-8f9a-3ab73158596e", "name": "p1rdt6581-p1rdt9084x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "169793d1-b20d-4e43-a918-a31b39feffe4"}}}}, {"uuid": "32d60b45-d56c-403d-99e5-72dbc6f6ee64", "name": "", "x": 38.65932938830671, "y": -122.45365277312096, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b2ce5116-c4f0-4ac7-a34f-3ba44c99d04b", "name": "p1rdt9076", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "32d60b45-d56c-403d-99e5-72dbc6f6ee64"}}}}, {"uuid": "ed78c300-b738-4256-82ac-69932d19430e", "name": "", "x": 38.6598966989538, "y": -122.45427706074868, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c29179f3-0b4e-449c-8562-a8fcb675be6c", "name": "p1rdt9093", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ed78c300-b738-4256-82ac-69932d19430e"}}}}, {"uuid": "67e13266-9238-4cad-9947-2673df4847a6", "name": "", "x": 38.658584295641674, "y": -122.4538145255183, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "12b4dc99-fe50-457c-90aa-48a2fb19ebf1", "name": "p1rdt9076-p1rdt9084x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "67e13266-9238-4cad-9947-2673df4847a6"}}}}, {"uuid": "783adc37-8f14-4fc0-9882-7ff2167cccc1", "name": "", "x": 38.65080476587911, "y": -122.46154361413883, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "563c6bb3-d8ed-4fce-ad66-3892426248df", "name": "p1rdt9091", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "783adc37-8f14-4fc0-9882-7ff2167cccc1"}}}}, {"uuid": "f8ebc8aa-10ca-4c4b-a76e-7b55f47da7af", "name": "", "x": 38.65078478496911, "y": -122.46111855767518, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7fcdf409-885c-4c95-834e-988842ed3f5c", "name": "p1rdt9085", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f8ebc8aa-10ca-4c4b-a76e-7b55f47da7af"}}}}, {"uuid": "20bb0b23-1255-4362-8a41-c2cb5865a639", "name": "", "x": 38.6513283597693, "y": -122.46332611842509, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf719d10-8168-4d80-894e-1b1516f033e8", "name": "p1rdt9090-p1rdt9091x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "20bb0b23-1255-4362-8a41-c2cb5865a639"}}}}, {"uuid": "9969e473-9935-40da-9183-2c6da735131b", "name": "", "x": 38.64979039983577, "y": -122.4656039969192, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a5f6a2ec-3ddd-4ba7-9c55-88b4d82e7735", "name": "p1rdt9469-p1rdt9470x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9969e473-9935-40da-9183-2c6da735131b"}}}}, {"uuid": "6263920c-9fc3-4b2e-a546-abbddd42605f", "name": "", "x": 38.65049921056124, "y": -122.46639198488886, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "acf91e46-ba32-44c3-a829-14c80a693d7d", "name": "p1rdt9470", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6263920c-9fc3-4b2e-a546-abbddd42605f"}}}}, {"uuid": "0a73ebe0-b63d-458f-a694-bef5e5e35908", "name": "", "x": 38.62473134403656, "y": -122.446341336382, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "431b672b-cb45-4294-b1f9-1d63f4efc8db", "name": "p1rdt5184", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a73ebe0-b63d-458f-a694-bef5e5e35908"}}}}, {"uuid": "40171f66-03ca-44d5-a7d9-dd81cd1d77d0", "name": "", "x": 38.62489829777773, "y": -122.44603739457851, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ceb58d66-3cb3-416d-aedf-f4949432eb37", "name": "p1rdt5140-p1rdt5184x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "40171f66-03ca-44d5-a7d9-dd81cd1d77d0"}}}}, {"uuid": "3c7c92ef-f3c4-4b07-a237-27029a3a135b", "name": "", "x": 38.625549640330384, "y": -122.44525871373254, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4b0fd055-d0ac-4678-a8e5-679e12741736", "name": "p1rdt5140", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3c7c92ef-f3c4-4b07-a237-27029a3a135b"}}}}, {"uuid": "ad9b4b7a-0931-459e-98b2-2be8e2026ce0", "name": "", "x": 38.62488841554401, "y": -122.44776290196933, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "50332aed-ecfd-465a-977e-c24ed6462860", "name": "p1rdt5154", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ad9b4b7a-0931-459e-98b2-2be8e2026ce0"}}}}, {"uuid": "8e9f56d8-7fca-4f4e-ae86-e65be9cb8c4f", "name": "", "x": 38.62229054802191, "y": -122.44975245942024, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d579047b-82f6-49bf-bd7b-28c818d44bb3", "name": "p1rdt5142", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8e9f56d8-7fca-4f4e-ae86-e65be9cb8c4f"}}}}, {"uuid": "d8684006-5b25-49fb-a434-cfc2f1c5dec1", "name": "", "x": 38.62220258438888, "y": -122.44622230651564, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c6316fa2-dd57-46d4-89c0-f11dd675d686", "name": "p1rdt5180", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d8684006-5b25-49fb-a434-cfc2f1c5dec1"}}}}, {"uuid": "0c16fccb-d717-44aa-9f38-45a6246e6956", "name": "", "x": 38.62380545487311, "y": -122.4562212466049, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b48f78d-1092-4536-bfb3-029da6a70dff", "name": "p1rdt8414", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0c16fccb-d717-44aa-9f38-45a6246e6956"}}}}, {"uuid": "1c64bcc6-45c2-4d20-8bf9-0e11de4c7265", "name": "", "x": 38.623626833691524, "y": -122.455467102224, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "50f71b3d-83ce-4526-8057-4a38042b7295", "name": "p1rdt5142-p1rdt8414x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1c64bcc6-45c2-4d20-8bf9-0e11de4c7265"}}}}, {"uuid": "0b35d36d-70fc-40d5-914c-1a06b686e5a9", "name": "", "x": 38.62564005248976, "y": -122.46602311753331, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "42929633-40d4-4e13-a0aa-a7682f328226", "name": "p1rdt6409", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0b35d36d-70fc-40d5-914c-1a06b686e5a9"}}}}, {"uuid": "319a6f16-24d3-4b77-b1e8-7f7402459352", "name": "", "x": 38.62467409594971, "y": -122.4578141983919, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c8648275-54c9-48e3-82e0-33119313924d", "name": "p1rdt6409-p1rdt8414x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "319a6f16-24d3-4b77-b1e8-7f7402459352"}}}}, {"uuid": "1e5d5efe-22c3-4d18-9fba-2f30ab355a68", "name": "", "x": 38.62028911584838, "y": -122.47934854754749, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f750e531-5ade-40a9-9bb0-042220ce9807", "name": "p1rdt9413", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1e5d5efe-22c3-4d18-9fba-2f30ab355a68"}}}}, {"uuid": "c9ef1203-c178-47da-b18f-e0dc8a149ce5", "name": "", "x": 38.607806368453346, "y": -122.45767322666612, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f9b94106-b7c5-4ce9-9c19-053487848c2a", "name": "p1rdt7570", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c9ef1203-c178-47da-b18f-e0dc8a149ce5"}}}}, {"uuid": "1ea6e363-b354-4950-a115-36df79ac7e00", "name": "", "x": 38.60650861543276, "y": -122.45746126944624, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fd487832-bc77-406f-a995-4b099fad7c64", "name": "p1rdt7574", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1ea6e363-b354-4950-a115-36df79ac7e00"}}}}, {"uuid": "a90235cd-9b37-4856-b9de-bb34434bd0c2", "name": "", "x": 38.61094163932077, "y": -122.45877502518786, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "08d4c459-5bc5-4cad-8e74-613c4a08cb35", "name": "p1rdt6275", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a90235cd-9b37-4856-b9de-bb34434bd0c2"}}}}, {"uuid": "2d935bfb-e43c-45ee-b5df-0d97d91514f4", "name": "", "x": 38.6129133935745, "y": -122.45941441983003, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3cf36152-b3af-49f7-b693-5d465db1f283", "name": "p1rdt6270", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2d935bfb-e43c-45ee-b5df-0d97d91514f4"}}}}, {"uuid": "dfb10ac3-d01d-4ffb-a16b-d27afac7c0cb", "name": "", "x": 38.61549898247823, "y": -122.4595395605965, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b5ef97a6-6c60-46eb-acce-6469b273658a", "name": "p1rdt6269", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dfb10ac3-d01d-4ffb-a16b-d27afac7c0cb"}}}}, {"uuid": "7ef54c91-36ce-43c7-8b71-0385b3d8dc94", "name": "", "x": 38.617305618456946, "y": -122.4643619588085, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60829dab-c129-4017-961a-81435d8afa93", "name": "p1rdt8405", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7ef54c91-36ce-43c7-8b71-0385b3d8dc94"}}}}, {"uuid": "f73d9123-c351-479d-ba0d-bfd88fcaeac1", "name": "", "x": 38.62031463672319, "y": -122.47930548988975, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16ecb938-cd0c-4be5-a915-be0d84d351f2", "name": "p1rdt8405-p1rdt9413x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f73d9123-c351-479d-ba0d-bfd88fcaeac1"}}}}, {"uuid": "1031a2c7-4eb4-4229-8c5a-3ba72e4b2638", "name": "", "x": 38.574957799581, "y": -122.51876395636346, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d25f8d60-8aa7-4975-96dc-eba7696fa8ae", "name": "p1rdt9314", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1031a2c7-4eb4-4229-8c5a-3ba72e4b2638"}}}}, {"uuid": "43aaaf9a-7585-41cb-8661-2358b2f561e5", "name": "", "x": 38.57551466426878, "y": -122.51886483712937, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d39c608-5688-4e22-8ac4-96b896265274", "name": "p1rdt6518", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "43aaaf9a-7585-41cb-8661-2358b2f561e5"}}}}, {"uuid": "31845f68-2f99-480e-95bc-602b2a660cb5", "name": "", "x": 38.57472269246426, "y": -122.51786257188046, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d9b006c3-79f8-4a27-b76a-d1b458ff2a21", "name": "p1rdt9479", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "31845f68-2f99-480e-95bc-602b2a660cb5"}}}}, {"uuid": "635efc5b-e76d-40a8-b026-2e8350de069e", "name": "", "x": 38.57508507780314, "y": -122.51765748560604, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9707f264-8f82-4483-8337-6c89d709faf7", "name": "p1rdt6539", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "635efc5b-e76d-40a8-b026-2e8350de069e"}}}}, {"uuid": "d5df494f-b6e9-4370-9ff0-795e3592612e", "name": "", "x": 38.575354576929136, "y": -122.51744904257968, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0db3e719-4dba-4b45-af70-c35546c19eb4", "name": "p1rdt6507", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d5df494f-b6e9-4370-9ff0-795e3592612e"}}}}, {"uuid": "6f46c81f-1ceb-4611-9652-4535d88f4fc6", "name": "", "x": 38.577519567449535, "y": -122.51578138154942, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "40ec7437-80f0-49e8-806a-c696b1402713", "name": "p1rdt6530", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6f46c81f-1ceb-4611-9652-4535d88f4fc6"}}}}, {"uuid": "33e0291b-9d5f-4928-95dc-45d472013d5d", "name": "", "x": 38.57798706705615, "y": -122.51470262020904, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b56340a0-81f0-4028-9283-532f0d92a412", "name": "p1rdt6517", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "33e0291b-9d5f-4928-95dc-45d472013d5d"}}}}, {"uuid": "f4d81409-19b9-4e42-a06c-3ce62f8ab4f9", "name": "", "x": 38.579746916502536, "y": -122.51263999956761, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "608945f2-9b19-43bc-83d9-0fe8787b06b4", "name": "p1rdt6517-p1rdt6523x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f4d81409-19b9-4e42-a06c-3ce62f8ab4f9"}}}}, {"uuid": "07f3008d-00cd-4df8-8bea-83653784bac1", "name": "", "x": 38.58000496177514, "y": -122.51234696117584, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "24028ccd-3fd3-4461-b83c-54266f91a385", "name": "p1rdt6520", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "07f3008d-00cd-4df8-8bea-83653784bac1"}}}}, {"uuid": "e3fa98f5-3d51-4345-84df-74893d453208", "name": "", "x": 38.57971971243869, "y": -122.51259440779317, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b540c710-395d-4a35-8dc3-59d37609df09", "name": "p1rdt6523", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e3fa98f5-3d51-4345-84df-74893d453208"}}}}, {"uuid": "515c2487-0a37-42d4-9ec4-2f5d75840d25", "name": "", "x": 38.58012887408336, "y": -122.51206038960157, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "99fa55d1-867c-4db0-8697-b532da10d6d4", "name": "p1rdt6501", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "515c2487-0a37-42d4-9ec4-2f5d75840d25"}}}}, {"uuid": "582e1fdd-0784-4e10-9065-38231440dc00", "name": "", "x": 38.580187053973766, "y": -122.51175395124783, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "89434ebc-1e79-4414-9925-1a14f8e72fd6", "name": "p1rdt6499", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "582e1fdd-0784-4e10-9065-38231440dc00"}}}}, {"uuid": "e50403c5-4866-4194-bb01-be0e09fa1377", "name": "", "x": 38.580244659409736, "y": -122.51143788792888, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e67c889f-e940-4242-9c83-4b5ab673d8a8", "name": "p1rdt6509", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e50403c5-4866-4194-bb01-be0e09fa1377"}}}}, {"uuid": "e659b9f0-3f1e-4b24-ab87-a5123dd51b1c", "name": "", "x": 38.58030980831637, "y": -122.51115038887805, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e165d0d-3f13-4d87-9c4b-fdfa8829f1f3", "name": "p1rdt6508", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e659b9f0-3f1e-4b24-ab87-a5123dd51b1c"}}}}, {"uuid": "b615cc6e-c30f-4996-882a-a05a0058354e", "name": "", "x": 38.580354920781474, "y": -122.5109491558155, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "302d2adf-2199-47b2-9f3c-e428bb409b6f", "name": "p1rdt6521", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b615cc6e-c30f-4996-882a-a05a0058354e"}}}}, {"uuid": "46ab54f2-6e29-4b41-b41f-06337d4964f7", "name": "", "x": 38.58042615056892, "y": -122.51074201742463, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6f7572ed-6443-4e6e-8fb8-0b060b9f17ce", "name": "p1rdt6512", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "46ab54f2-6e29-4b41-b41f-06337d4964f7"}}}}, {"uuid": "3b809375-b5a2-4775-a0b9-2676d6fda7d7", "name": "", "x": 38.58053498950995, "y": -122.5103355002012, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1ef8c502-c06f-43e5-90e6-23bd0ebcf155", "name": "p1rdt6524", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3b809375-b5a2-4775-a0b9-2676d6fda7d7"}}}}, {"uuid": "d69f12ba-021d-452d-bb69-d958c3a8cb16", "name": "", "x": 38.56382999437341, "y": -122.50863846453362, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6372a592-5e2d-41c8-819b-f56bfbb58e19", "name": "p1rdt7091", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d69f12ba-021d-452d-bb69-d958c3a8cb16"}}}}, {"uuid": "69d63238-38a7-42a0-8a20-6c9477697ccb", "name": "", "x": 38.5636996056699, "y": -122.50885698702933, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2324afa4-5274-4392-9a0e-be8dc2bebeba", "name": "p1rdt7091-p1rdt7625x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "69d63238-38a7-42a0-8a20-6c9477697ccb"}}}}, {"uuid": "37c17271-1d66-4530-babf-ba7c9bb6114e", "name": "", "x": 38.56314359789373, "y": -122.50948068684706, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3e6cbe9-d1d3-4c59-981f-dad980f0999b", "name": "p1rdt7625", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "37c17271-1d66-4530-babf-ba7c9bb6114e"}}}}, {"uuid": "dbff52e8-5b75-4845-8a22-7f8073c4f4bc", "name": "", "x": 38.56813752425825, "y": -122.50551166975698, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0cf1844f-a32e-40f2-bc96-05fad3bdd88d", "name": "p1rdt7314", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dbff52e8-5b75-4845-8a22-7f8073c4f4bc"}}}}, {"uuid": "bda52bf5-41bc-46b2-9c3d-66ebc4d33d9b", "name": "", "x": 38.56852875024663, "y": -122.50519721502558, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e86bc267-1607-4aa3-916f-ed826b0adfdc", "name": "p1rdt7318", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bda52bf5-41bc-46b2-9c3d-66ebc4d33d9b"}}}}, {"uuid": "f6353f32-6099-411d-a61a-5f3301e972e7", "name": "", "x": 38.57391341112913, "y": -122.50681689306278, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "231b5cf9-ec2c-47d1-aada-5454926561dd", "name": "p1rdt7307", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f6353f32-6099-411d-a61a-5f3301e972e7"}}}}, {"uuid": "17d081fe-5198-48d6-90b7-5bfaead55094", "name": "", "x": 38.57883713707986, "y": -122.51041811805065, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8431ef4c-78dd-4a39-b15a-95818cfe1d86", "name": "p1rdt6531-p1rdt7307x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "17d081fe-5198-48d6-90b7-5bfaead55094"}}}}, {"uuid": "1a2eb0e7-c58b-47f3-9b0b-89750d713fe9", "name": "", "x": 38.57902238646377, "y": -122.51037187678122, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "483b2d65-b496-4c6f-b01d-66aa3d9d4334", "name": "p1rdt6527", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1a2eb0e7-c58b-47f3-9b0b-89750d713fe9"}}}}, {"uuid": "353fee29-202d-4129-a38e-30d19f45d48a", "name": "", "x": 38.57879504932116, "y": -122.51042237415348, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "385eabe4-8c8e-4354-96ec-931e6c25574d", "name": "p1rdt6531", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "353fee29-202d-4129-a38e-30d19f45d48a"}}}}, {"uuid": "9feadd92-cb06-4c71-af76-75d239af08d9", "name": "", "x": 38.57912969611421, "y": -122.51047132869749, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5bd908fd-8bb8-42c1-8d1b-27c4e2574450", "name": "p1rdt6516", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9feadd92-cb06-4c71-af76-75d239af08d9"}}}}, {"uuid": "f6082925-7139-4fd8-aabe-610e992c29c1", "name": "", "x": 38.57925217424879, "y": -122.51051911433764, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6191a237-532b-44e2-86a8-d9ed56b914b5", "name": "p1rdt6516-p1rdt6524x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f6082925-7139-4fd8-aabe-610e992c29c1"}}}}, {"uuid": "fea2501d-3188-46ea-999f-cd8c413e6241", "name": "", "x": 38.580795923241645, "y": -122.50969387468216, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6a3d9ed9-e2e4-4332-89a2-358441869830", "name": "p1rdt6500-p1rdt6524x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fea2501d-3188-46ea-999f-cd8c413e6241"}}}}, {"uuid": "033688ee-3963-47a5-b30e-240a541604b3", "name": "", "x": 38.58050902502442, "y": -122.51029289847199, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "97b7ef3c-ef16-4c4d-8559-722c5c67749a", "name": "p1rdt6500-p1rdt6524xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "033688ee-3963-47a5-b30e-240a541604b3"}}}}, {"uuid": "5dac2af1-c479-42f6-95d6-e100063c675f", "name": "", "x": 38.58110574867303, "y": -122.50932633681218, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "18b822d0-cbe4-48d7-a818-87e25412d241", "name": "p1rdt6500-p1rdt6515xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5dac2af1-c479-42f6-95d6-e100063c675f"}}}}, {"uuid": "e564fdf3-ba34-4758-b781-3ed6d147914d", "name": "", "x": 38.58088888848231, "y": -122.50970513801667, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0043b26d-8a33-4e32-a963-c4638f943775", "name": "p1rdt6500-p1rdt6515x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e564fdf3-ba34-4758-b781-3ed6d147914d"}}}}, {"uuid": "e0de6dd3-0811-4bf9-a6ab-34bca44c5080", "name": "", "x": 38.58110455057315, "y": -122.5093365351204, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "04c3a970-215a-4e16-a798-80496ffad438", "name": "p1rdt6515-p1rdt6528xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e0de6dd3-0811-4bf9-a6ab-34bca44c5080"}}}}, {"uuid": "cf445906-c1c3-4e18-86a9-61dd94fab3a3", "name": "", "x": 38.58101245616958, "y": -122.50933552593602, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8dcd059f-292b-4f7a-96c1-a3dc185f1eec", "name": "p1rdt6515-p1rdt6528x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cf445906-c1c3-4e18-86a9-61dd94fab3a3"}}}}, {"uuid": "003fd690-4612-4698-bd6f-501feea117d2", "name": "", "x": 38.58147116472299, "y": -122.50902570371277, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "918984ec-3b5f-4174-9bca-771bb10e0f60", "name": "p1rdt6528-p1rdt8898xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "003fd690-4612-4698-bd6f-501feea117d2"}}}}, {"uuid": "0753826c-0c48-45ad-856a-f3ea5b33be40", "name": "", "x": 38.5810944181135, "y": -122.50923796161061, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0156ae64-03dc-4ec0-89c8-8b09a6fc9090", "name": "p1rdt6528-p1rdt8898x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0753826c-0c48-45ad-856a-f3ea5b33be40"}}}}, {"uuid": "fb1daff8-5e70-4d5f-80eb-6a7f365b58e0", "name": "", "x": 38.581587918670415, "y": -122.50894214477799, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b51e96e7-2d7f-42af-9115-c9b1cfb3131c", "name": "p1rdt6532-p1rdt8898x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fb1daff8-5e70-4d5f-80eb-6a7f365b58e0"}}}}, {"uuid": "26aa73db-5454-4f33-ba1b-b5e77e453ecf", "name": "", "x": 38.5813985191289, "y": -122.5089902200945, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "af1707bf-0b2e-4f76-96e7-c01338300d45", "name": "p1rdt6532-p1rdt8898xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "26aa73db-5454-4f33-ba1b-b5e77e453ecf"}}}}, {"uuid": "3573d3c0-5f83-4628-8077-f75cd6245d5b", "name": "", "x": 38.581811295389215, "y": -122.50861649779817, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e4a0469e-1a4a-466d-b18d-f3017b6415ae", "name": "p1rdt6532-p1rdt8902xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3573d3c0-5f83-4628-8077-f75cd6245d5b"}}}}, {"uuid": "311042de-27e1-40a3-87b6-e39cf7548d48", "name": "", "x": 38.581516114078376, "y": -122.50890397337818, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4f373554-9d8a-4a9c-b418-25e67fbb43a9", "name": "p1rdt6532-p1rdt8902x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "311042de-27e1-40a3-87b6-e39cf7548d48"}}}}, {"uuid": "c8f27702-2cc7-4484-93fd-58e51c0fb16e", "name": "", "x": 38.58365359761406, "y": -122.50734451106864, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "68b101ef-d71a-44d2-b1c2-4fc5e9f62499", "name": "p1rdt6052-p1rdt8902x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c8f27702-2cc7-4484-93fd-58e51c0fb16e"}}}}, {"uuid": "a9c3cd5e-cc7b-414b-b943-114ee1ba9f67", "name": "", "x": 38.58185095473939, "y": -122.50866687243757, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "468b1ce8-18fa-423b-99ca-1f3784437721", "name": "p1rdt6052-p1rdt8902xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a9c3cd5e-cc7b-414b-b943-114ee1ba9f67"}}}}, {"uuid": "b27f0dc4-65b4-473e-abdb-c08955bb9f83", "name": "", "x": 38.58373478464309, "y": -122.50725547084005, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "99e2ec8b-60fc-4a79-9eed-0d617babcb1d", "name": "p1rdt6046-p1rdt6052x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b27f0dc4-65b4-473e-abdb-c08955bb9f83"}}}}, {"uuid": "bc30bfc5-b613-42c4-8648-b0da774761d0", "name": "", "x": 38.583726243675486, "y": -122.5073799941088, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "49c69b43-f43b-4576-bbfa-d06b1d27de95", "name": "p1rdt6046-p1rdt6052xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bc30bfc5-b613-42c4-8648-b0da774761d0"}}}}, {"uuid": "fd4305f4-813c-4155-9c8f-cc87a063a114", "name": "", "x": 38.583771567152084, "y": -122.5072620145205, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be3d7f84-84e7-46fc-a9ce-b3e0cf74d1d3", "name": "p1rdt6043-p1rdt6046x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fd4305f4-813c-4155-9c8f-cc87a063a114"}}}}, {"uuid": "65e729c9-72ca-4616-b134-969f2edf5e19", "name": "", "x": 38.583673113710276, "y": -122.507315876951, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a147dd91-5597-40ff-93f9-0522ad3c726c", "name": "p1rdt6043-p1rdt6046xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65e729c9-72ca-4616-b134-969f2edf5e19"}}}}, {"uuid": "78471c56-df6e-47cb-97a4-ec628ff465c4", "name": "", "x": 38.583737845666946, "y": -122.50660841152015, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6f01bba4-b8e8-45ed-af3b-1ac5a287ad46", "name": "p1rdt6043-p1rdt6045xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "78471c56-df6e-47cb-97a4-ec628ff465c4"}}}}, {"uuid": "5dd9ba6c-e61b-463f-a515-95b3ddfd6abd", "name": "", "x": 38.58376143292759, "y": -122.50716343767925, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48d6768a-45e6-48a5-b22d-d5d418cb6221", "name": "p1rdt6043-p1rdt6045x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5dd9ba6c-e61b-463f-a515-95b3ddfd6abd"}}}}, {"uuid": "fcc2a891-40fa-4b5c-bdd9-244cef4e93a7", "name": "", "x": 38.584313677622774, "y": -122.50614079151774, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "34a9d21e-bcf7-4266-9834-60a72878ddd4", "name": "p1rdt6047", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fcc2a891-40fa-4b5c-bdd9-244cef4e93a7"}}}}, {"uuid": "e939a1b6-cedc-4d65-858d-686681519111", "name": "", "x": 38.58376381148312, "y": -122.50665101380328, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0396342e-2dc8-4a01-9da9-513953f9b5fa", "name": "p1rdt6045", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e939a1b6-cedc-4d65-858d-686681519111"}}}}, {"uuid": "b1e530e0-7893-4451-964c-130b7125f7f1", "name": "", "x": 38.58637708588061, "y": -122.50393363509188, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f8898950-d712-40dc-99b5-33882b96b225", "name": "p1rdt6038", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b1e530e0-7893-4451-964c-130b7125f7f1"}}}}, {"uuid": "da6f6b5b-8559-41f7-af03-efce97dc18cd", "name": "", "x": 38.59928901894631, "y": -122.48316671744382, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a086b782-3a8d-44e9-9948-cb7f051219e3", "name": "p1rdt7599", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "da6f6b5b-8559-41f7-af03-efce97dc18cd"}}}}, {"uuid": "609ac35d-fcd1-4ca4-ac26-5508b44e4ee4", "name": "", "x": 38.58770893471679, "y": -122.5028146867888, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3cfe89e9-a7a8-456d-966b-67429017f456", "name": "p1rdt6038-p1rdt7599x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "609ac35d-fcd1-4ca4-ac26-5508b44e4ee4"}}}}, {"uuid": "9b4fde9b-7944-467b-a9f5-52d268a644ee", "name": "", "x": 38.600060944468346, "y": -122.4812911472599, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0809ec5e-d36f-4bea-91b3-962ad6c29606", "name": "p1rdt6221", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9b4fde9b-7944-467b-a9f5-52d268a644ee"}}}}, {"uuid": "24852869-a1c5-4db0-95e5-c320b2bdc195", "name": "", "x": 38.60505176311642, "y": -122.47599334604853, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cdfc617f-fbfb-4e9a-862e-cd5a296748cb", "name": "p1rdt6208", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "24852869-a1c5-4db0-95e5-c320b2bdc195"}}}}, {"uuid": "d3816b74-5540-46d7-bb85-811d4c985b35", "name": "", "x": 38.60037508320662, "y": -122.48099954218519, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e1a5a109-eee6-46be-be53-3fbe4a406575", "name": "p1rdt6208-p1rdt6221x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d3816b74-5540-46d7-bb85-811d4c985b35"}}}}, {"uuid": "09ec30ea-572f-4201-ab0e-bcaa5f62e366", "name": "", "x": 38.60815051684694, "y": -122.4765469245405, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "89f0c671-9d27-4dec-bd37-dc6c56f07e5d", "name": "p1rdt6208-p1rdt8805x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "09ec30ea-572f-4201-ab0e-bcaa5f62e366"}}}}, {"uuid": "af24f76a-b2a7-4be6-998a-9c8b47186469", "name": "", "x": 38.57279151417879, "y": -122.49288162437385, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "17e89212-bc51-4fc2-83d1-4c74a285be23", "name": "p1rdt5662", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "af24f76a-b2a7-4be6-998a-9c8b47186469"}}}}, {"uuid": "9223305e-a3da-4bbd-ada6-4a46ca8d1722", "name": "", "x": 38.57272640832975, "y": -122.49539881317247, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6f2bb66-d966-4228-8a13-96c57e8fbfba", "name": "p1rdt5656-p1rdt5662x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9223305e-a3da-4bbd-ada6-4a46ca8d1722"}}}}, {"uuid": "82ef4fd2-7195-44ec-84b9-64fa3ab7a3f0", "name": "", "x": 38.57265915120934, "y": -122.49564074606137, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f417a58d-5a47-4310-bac6-e8bb95fffc19", "name": "p1rdt5656", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "82ef4fd2-7195-44ec-84b9-64fa3ab7a3f0"}}}}, {"uuid": "4a9b2caa-f848-47c9-a059-957fa52f8f06", "name": "", "x": 38.58485209359688, "y": -122.4751287858777, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "23f0bb81-3c30-45a5-89ca-2011e3881ddb", "name": "p1rdt5183", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4a9b2caa-f848-47c9-a059-957fa52f8f06"}}}}, {"uuid": "b270cdf3-cf3c-4029-a234-1c61167c5fda", "name": "", "x": 38.57451035345935, "y": -122.49113876914703, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a05b2959-a8dd-417b-b566-8f84384a3559", "name": "p1rdt5183-p1rdt5662x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b270cdf3-cf3c-4029-a234-1c61167c5fda"}}}}, {"uuid": "2a0c5a2b-f586-42b2-8ffd-fe3202072fa0", "name": "", "x": 38.58726329125732, "y": -122.47503377407112, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35487e15-57cb-4e19-bef7-49074e5eb9ee", "name": "p1rdt4980-p1rdt5183x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2a0c5a2b-f586-42b2-8ffd-fe3202072fa0"}}}}, {"uuid": "d21b0e02-57ba-4706-b64c-bf0090e0ea77", "name": "", "x": 38.588776084576374, "y": -122.47343214290899, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6c09f718-9379-4281-86f6-55c46e46aec6", "name": "p1rdt5017", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d21b0e02-57ba-4706-b64c-bf0090e0ea77"}}}}, {"uuid": "156e698e-e740-43b4-a724-4c7512ab895f", "name": "", "x": 38.58727709580159, "y": -122.47498276916237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6ddb0629-4947-47ca-83f9-9b7c073db235", "name": "p1rdt4980", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "156e698e-e740-43b4-a724-4c7512ab895f"}}}}, {"uuid": "ddb76e34-841b-49c0-b867-d88bea22d92a", "name": "", "x": 38.58932620721099, "y": -122.47402937641733, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f7f13598-e628-457c-9ba6-d9a0123e882c", "name": "p1rdt4964", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ddb76e34-841b-49c0-b867-d88bea22d92a"}}}}, {"uuid": "22773cea-500b-4798-8aa4-1df98c90efb3", "name": "", "x": 38.58925865771824, "y": -122.47388020936008, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf1c765f-ca54-48cf-806f-6a1b5719c4b0", "name": "p1rdt4964-p1rdt5017x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "22773cea-500b-4798-8aa4-1df98c90efb3"}}}}, {"uuid": "ab497915-2f5e-4f84-afff-5092914cbc85", "name": "", "x": 38.599541593142376, "y": -122.47111831101633, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "42ab6054-1866-49c5-b2ab-3cf27199c1c8", "name": "p1rdt8154", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ab497915-2f5e-4f84-afff-5092914cbc85"}}}}, {"uuid": "6f44f73f-9fc9-4ff0-b2a7-29b6a0732165", "name": "", "x": 38.59202547989681, "y": -122.47391743009182, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fb1e0d86-907d-4564-a90e-c1400917d3ca", "name": "p1rdt4964-p1rdt8154x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6f44f73f-9fc9-4ff0-b2a7-29b6a0732165"}}}}, {"uuid": "ae7ca9ea-21fa-4d1d-81bd-d01623b8672e", "name": "", "x": 38.599346582191174, "y": -122.4698450346779, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b44d5021-4fdb-4618-bcb2-237ecf2e10e4", "name": "p1rdt8153", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ae7ca9ea-21fa-4d1d-81bd-d01623b8672e"}}}}, {"uuid": "da4c3120-9386-4ac0-a965-1d368dc4eb77", "name": "", "x": 38.59932444954078, "y": -122.4697759036714, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "40962258-28d3-4406-9e9e-121f373cce25", "name": "p1rdt8151-p1rdt8153x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "da4c3120-9386-4ac0-a965-1d368dc4eb77"}}}}, {"uuid": "a605e89a-2a49-4fb3-a6a6-235d6b52275e", "name": "", "x": 38.599762625990174, "y": -122.46808190408947, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6c794942-d5ce-481f-9c6a-563a2180a4ba", "name": "p1rdt8151", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a605e89a-2a49-4fb3-a6a6-235d6b52275e"}}}}, {"uuid": "cb85fe25-d34d-4660-90eb-26a04f0f26af", "name": "", "x": 38.605132002398605, "y": -122.47349749138557, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0da91bf8-b687-47df-a7dc-41e6166fd667", "name": "p1rdt9333", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb85fe25-d34d-4660-90eb-26a04f0f26af"}}}}, {"uuid": "5bf299c2-dd95-465a-bd1c-6550b9c7ecd1", "name": "", "x": 38.60218088899386, "y": -122.47169573381588, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0aef77ef-aaaa-4a6e-90ef-87348baaf1a0", "name": "p1rdt8154-p1rdt9333x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5bf299c2-dd95-465a-bd1c-6550b9c7ecd1"}}}}, {"uuid": "7ed57c9a-f3a4-432d-931f-5fcbd8226827", "name": "", "x": 38.608136170076634, "y": -122.47649614861295, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3444af6b-f9d4-4229-b6b2-2114300c3f94", "name": "p1rdt8805", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7ed57c9a-f3a4-432d-931f-5fcbd8226827"}}}}, {"uuid": "9361e3c5-5508-49d1-8324-50197f15d00b", "name": "", "x": 38.609815768546184, "y": -122.4765312522036, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "26ccaeff-3a34-4835-8906-1145148549c6", "name": "p1rdt8802", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9361e3c5-5508-49d1-8324-50197f15d00b"}}}}, {"uuid": "f2365584-be6c-4540-994c-e874243d629f", "name": "", "x": 38.609928396533334, "y": -122.47651694646427, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "401576cc-4ad6-42cd-bf1c-4022da720711", "name": "p1rdt8802-p1rdt9413xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f2365584-be6c-4540-994c-e874243d629f"}}}}, {"uuid": "f510224a-87d0-4a9f-8bfe-1825b789e2b8", "name": "", "x": 38.618837809141326, "y": -122.47838533286804, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e527bf48-b574-43bd-9a5d-484654dc76fe", "name": "p1rdt8802-p1rdt9413x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f510224a-87d0-4a9f-8bfe-1825b789e2b8"}}}}, {"uuid": "f194c891-16c9-4a51-b620-232d3a58f3c7", "name": "", "x": 38.62912673381444, "y": -122.48799793138168, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c0dafde2-c08e-4624-9212-e0fea9e47c2c", "name": "p1rdt5126", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f194c891-16c9-4a51-b620-232d3a58f3c7"}}}}, {"uuid": "93aa763a-d394-4fea-a89b-8ff3e9f2f138", "name": "", "x": 38.64192278671691, "y": -122.50364415036834, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4c8f9ea6-06fb-4fd0-8629-ceea4f32189f", "name": "p1rdt5342", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "93aa763a-d394-4fea-a89b-8ff3e9f2f138"}}}}, {"uuid": "e897b484-4f5d-4511-96ed-69f112c49f0c", "name": "", "x": 38.63755626056743, "y": -122.46589422645306, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7e240270-762d-49f0-a4e4-29fcd6273ce5", "name": "p1rdt7624", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e897b484-4f5d-4511-96ed-69f112c49f0c"}}}}, {"uuid": "0d2d5b6d-abe4-4eb9-ab07-26bdb36af719", "name": "", "x": 38.63942506778048, "y": -122.46168548768624, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b077dc9c-1c6f-4403-ae0c-954e7cc0c692", "name": "p1rdt5476", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0d2d5b6d-abe4-4eb9-ab07-26bdb36af719"}}}}, {"uuid": "148a4099-82af-42f4-b914-66cf29ec0d00", "name": "", "x": 38.643194242872035, "y": -122.47115740856567, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "42b9c576-ddba-4be1-bc64-a37d8cbdfa84", "name": "p1rdt8159", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "148a4099-82af-42f4-b914-66cf29ec0d00"}}}}, {"uuid": "91243721-ce14-4cc8-a69c-acbee3ff9fda", "name": "", "x": 38.64188879325188, "y": -122.47007141909909, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d1ab9716-b9f3-44e5-b9f6-cd83d0904dd3", "name": "p1rdt7624-p1rdt8159x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "91243721-ce14-4cc8-a69c-acbee3ff9fda"}}}}, {"uuid": "cff42dc3-ba94-4c55-a541-87283cc47044", "name": "", "x": 38.64458771393313, "y": -122.47217469285334, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25946c74-15c2-412c-baed-8de5f7aecf98", "name": "p1rdt8161", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cff42dc3-ba94-4c55-a541-87283cc47044"}}}}, {"uuid": "ced643af-8d28-41e7-81bc-9298c8c8a7c1", "name": "", "x": 38.64808407134208, "y": -122.45916844730037, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f31b09da-e4cc-409e-9634-1907480039ff", "name": "p1rdt7253", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ced643af-8d28-41e7-81bc-9298c8c8a7c1"}}}}, {"uuid": "9f7fd998-363e-47bc-a5ec-6acba95517ae", "name": "", "x": 38.64789780072754, "y": -122.44172571021984, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "442de065-9e2a-4ff8-9100-1298d3fe0f6f", "name": "p1rdt8470", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9f7fd998-363e-47bc-a5ec-6acba95517ae"}}}}, {"uuid": "33742eaa-2507-43f4-8e91-c5c625e02232", "name": "", "x": 38.648387196658014, "y": -122.46102160071564, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7a006c5f-e960-4ae2-a37f-d23d7b873a22", "name": "p1rdt7248", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "33742eaa-2507-43f4-8e91-c5c625e02232"}}}}, {"uuid": "7104919f-4adc-4a80-8457-659bf8f006bc", "name": "", "x": 38.64846046981178, "y": -122.46458969235934, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a2f1a631-48f7-4291-9adb-588a66620ebf", "name": "p1rdt7220", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7104919f-4adc-4a80-8457-659bf8f006bc"}}}}, {"uuid": "60ab8c09-8396-4f17-b6fd-aa407a787161", "name": "", "x": 38.64777195633766, "y": -122.46661554016796, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "38b72c12-2e2f-4d83-8f5a-9d8503dc29eb", "name": "p1rdt8160", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "60ab8c09-8396-4f17-b6fd-aa407a787161"}}}}, {"uuid": "11246cdc-f535-43ac-bc2f-283ef1067f9a", "name": "", "x": 38.655229305360514, "y": -122.45615922843626, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "907828f5-8e26-41c4-8fbc-a3744608181a", "name": "p1rdt9075", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "11246cdc-f535-43ac-bc2f-283ef1067f9a"}}}}, {"uuid": "e870ef83-64a3-438a-8029-6d8886b57301", "name": "", "x": 38.65752720541336, "y": -122.45501513442589, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c10b6848-6c57-4243-8cb9-ec28d0a4c9dd", "name": "p1rdt9075-p1rdt9084x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e870ef83-64a3-438a-8029-6d8886b57301"}}}}, {"uuid": "815040ca-6a4c-4405-8579-ff7a3f914bfc", "name": "", "x": 38.65853988991046, "y": -122.45382366130036, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4251587d-600f-40a0-9aec-229fb2e3f2df", "name": "p1rdt9084", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "815040ca-6a4c-4405-8579-ff7a3f914bfc"}}}}, {"uuid": "cd1cc0f4-b4ac-4522-bdd8-e3dc70594d6a", "name": "", "x": 38.652201124748096, "y": -122.4614412233577, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0b7f2f09-976a-45da-8186-229aeedeb689", "name": "p1rdt9077", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cd1cc0f4-b4ac-4522-bdd8-e3dc70594d6a"}}}}, {"uuid": "9d8b7eaa-852a-4c6d-b0c9-1b2426b9217a", "name": "", "x": 38.65243762839318, "y": -122.46214490936109, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1b4ec275-bea8-45f2-94cb-5e24e82179d8", "name": "p1rdt9089", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9d8b7eaa-852a-4c6d-b0c9-1b2426b9217a"}}}}, {"uuid": "0616daa6-3191-4406-9a69-d24e5f3a9dd4", "name": "", "x": 38.65135661168091, "y": -122.46337071841116, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "52c72b52-1c6c-46f6-adbe-1054eb233c20", "name": "p1rdt9090", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0616daa6-3191-4406-9a69-d24e5f3a9dd4"}}}}, {"uuid": "e4ace3e4-f86a-4403-840c-5233a8d47f89", "name": "", "x": 38.65237921170061, "y": -122.46231727928001, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e4d2db3-67c5-4fef-996a-5774803c89b1", "name": "p1rdt9089-p1rdt9090x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e4ace3e4-f86a-4403-840c-5233a8d47f89"}}}}, {"uuid": "f6b9afad-4208-4121-9829-dc64e012f791", "name": "", "x": 38.649831613431125, "y": -122.46561633896845, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3fd32c7-2866-4699-93a8-dd3a9997d349", "name": "p1rdt9469", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f6b9afad-4208-4121-9829-dc64e012f791"}}}}, {"uuid": "b4d949aa-8e70-4f2e-b001-812a6d42b686", "name": "", "x": 38.65039847441097, "y": -122.46468794326384, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "708803a5-3daf-4892-96e3-b182e2d214ec", "name": "p1rdt9090-p1rdt9469x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b4d949aa-8e70-4f2e-b001-812a6d42b686"}}}}, {"uuid": "ba7b18f7-6460-41e0-9b2b-3f9af5c9c69c", "name": "", "x": 38.64456173566906, "y": -122.4721320674015, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c8ecbd5b-6db5-44a0-b2a8-0233d4eb5b20", "name": "p1rdt8160-p1rdt8161xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ba7b18f7-6460-41e0-9b2b-3f9af5c9c69c"}}}}, {"uuid": "331f72b2-c8fa-4979-a0f4-6b7c8286c289", "name": "", "x": 38.645703216313166, "y": -122.47060639662344, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cc9cbaf2-05bd-49aa-bd14-a363d4970d0f", "name": "p1rdt8160-p1rdt8161x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "331f72b2-c8fa-4979-a0f4-6b7c8286c289"}}}}, {"uuid": "d7c8d0dd-b7e9-4606-b2ed-56da52b32e46", "name": "", "x": 38.641446776145905, "y": -122.48088775120242, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "22db53ea-6d9a-4527-9b36-34a4bcd2c74f", "name": "p1rdt5236", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d7c8d0dd-b7e9-4606-b2ed-56da52b32e46"}}}}, {"uuid": "f3e02c92-fbc6-412b-8ea3-c179fa8c1404", "name": "", "x": 38.64423596256915, "y": -122.47297284989183, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "67967bdd-155c-49fd-8d4c-29b40415a243", "name": "p1rdt5236-p1rdt8161x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f3e02c92-fbc6-412b-8ea3-c179fa8c1404"}}}}, {"uuid": "4ae6ae6c-48be-4637-a5e1-b25dc9fa53b0", "name": "", "x": 38.64189681984152, "y": -122.50360151499711, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9bbfae79-a578-4ff2-b622-3dddd9859ac8", "name": "p1rdt5236-p1rdt5342x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ae6ae6c-48be-4637-a5e1-b25dc9fa53b0"}}}}, {"uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac", "name": "", "limit_type": "min", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "base"}}, "value": {"value": 0.26327172275046934, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}}, {"uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b", "name": "", "limit_type": "max", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "base"}}, "value": {"value": 0.2909845356715714, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}}, {"uuid": "c506c458-594e-4c5f-9e1f-7e22db8220b6", "name": "", "x": 38.62487405627925, "y": -122.44771212016306, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9750085f-4afd-48ee-89f3-edbe9687b242", "name": "p1rdt5154lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c506c458-594e-4c5f-9e1f-7e22db8220b6"}}}}, {"uuid": "090a2c8f-a953-4cac-b416-8e61fbf2d4b4", "name": "", "x": 38.62484806916583, "y": -122.44766951523545, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "08331744-08b7-455e-b2ca-284cae95fb06", "name": "p1rlv10539", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "090a2c8f-a953-4cac-b416-8e61fbf2d4b4"}}}}, {"uuid": "80a16f1a-9fbf-462f-b254-04a16da0b948", "name": "", "x": 38.62592881156844, "y": -122.44183363220685, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7235cf3a-dd26-47f7-884c-6335024a3064", "name": "p1rdt7632lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "80a16f1a-9fbf-462f-b254-04a16da0b948"}}}}, {"uuid": "18196f08-5ffc-4531-9ce1-984f0bd06c0b", "name": "", "x": 38.62591502181451, "y": -122.4418846707521, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "606bf8f6-d745-4220-8cae-e01ffd22f669", "name": "p1rlv16271", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "18196f08-5ffc-4531-9ce1-984f0bd06c0b"}}}}, {"uuid": "4739b7b5-d6d6-4a0f-bdca-ee44962ae707", "name": "", "x": 38.6268422350558, "y": -122.44358917844923, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b336e76f-17f3-4f5d-ba84-f24c3a4e3eed", "name": "p1rdt9265", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4739b7b5-d6d6-4a0f-bdca-ee44962ae707"}}}}, {"uuid": "9eb2fe35-b2d7-4c73-bc6a-9b8f07206031", "name": "", "x": 38.62595431848947, "y": -122.4417905580223, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "36e7cd28-6795-41d5-847d-92347871384f", "name": "p1rdt7632", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9eb2fe35-b2d7-4c73-bc6a-9b8f07206031"}}}}, {"uuid": "525621bc-eb00-4748-9592-9b3796d898ad", "name": "", "x": 38.626761518561686, "y": -122.44366797538842, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60837f06-40cb-4f12-b36f-fe5e502c96d9", "name": "p1rdt5140-p1rdt9265x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "525621bc-eb00-4748-9592-9b3796d898ad"}}}}, {"uuid": "0510f432-bc9d-4b48-a131-cc95b95f987b", "name": "", "x": 38.61321159266958, "y": -122.45774317693665, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a6614f5e-517f-46cf-b049-09337d57228a", "name": "p1rdt6279lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0510f432-bc9d-4b48-a131-cc95b95f987b"}}}}, {"uuid": "ffeb8cee-60ff-44ce-9b89-c90087251208", "name": "", "x": 38.613584450478484, "y": -122.45866725103048, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d46fd47-37f5-48a0-ba0d-d0746e6e6da3", "name": "p1rlv13061", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ffeb8cee-60ff-44ce-9b89-c90087251208"}}}}, {"uuid": "a7225ef2-cbbe-49a3-8b48-2c2e91ae95c5", "name": "", "x": 38.6133095747888, "y": -122.45770086863982, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cb21415c-fc85-4197-82e5-545cb7be2ce9", "name": "p1rdt6270-p1rdt6279x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a7225ef2-cbbe-49a3-8b48-2c2e91ae95c5"}}}}, {"uuid": "099a9c55-b1e0-4be0-af0f-adc080f914d6", "name": "", "x": 38.612910443068216, "y": -122.45907432656523, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e1565cfb-f699-47db-9cbf-a76c32e3ea69", "name": "p1rdt6270-p1rdt6279xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "099a9c55-b1e0-4be0-af0f-adc080f914d6"}}}}, {"uuid": "0c2c958b-2765-4873-9426-4fa8b298bc4c", "name": "", "x": 38.61301688005345, "y": -122.45941707430568, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5c579309-9c05-4bae-ab97-2eca485e5ea7", "name": "p1rdt6270-p1rdt6279xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0c2c958b-2765-4873-9426-4fa8b298bc4c"}}}}, {"uuid": "be1c5948-74ad-4790-a797-5c9bd7d6e7f9", "name": "", "x": 38.61683166262397, "y": -122.45474510217191, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "07992f45-0c92-4a10-837d-4f58599d9b75", "name": "p1rdt6273lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be1c5948-74ad-4790-a797-5c9bd7d6e7f9"}}}}, {"uuid": "6be47282-79b1-4511-94e5-ba580ff9b1bf", "name": "", "x": 38.61682643350382, "y": -122.4546916792451, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "051eba03-4728-4626-8add-5410b5326dc7", "name": "p1rlv13050", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6be47282-79b1-4511-94e5-ba580ff9b1bf"}}}}, {"uuid": "b647496e-436e-4fc4-84b3-eded4e8a1dbb", "name": "", "x": 38.6162564916241, "y": -122.45492283366434, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b2f8b91d-339f-4151-90df-b0cad5c2f05a", "name": "p1rdt6268", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b647496e-436e-4fc4-84b3-eded4e8a1dbb"}}}}, {"uuid": "db758a6a-9d1d-4ea1-816d-048640f12fc9", "name": "", "x": 38.61683285323747, "y": -122.45479901485551, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4d04f281-f394-432b-8b5c-cc1acb741369", "name": "p1rdt6273", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "db758a6a-9d1d-4ea1-816d-048640f12fc9"}}}}, {"uuid": "57780dd4-af7d-49dd-9de4-ad650c6a06a4", "name": "", "x": 38.61589336043255, "y": -122.45601994462623, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b31c2adb-e4f4-4211-aac7-f317bf325d12", "name": "p1rdt6268-p1rdt6276xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "57780dd4-af7d-49dd-9de4-ad650c6a06a4"}}}}, {"uuid": "d29d0187-de06-4d15-97ce-b21f4a1f04fa", "name": "", "x": 38.61634551176407, "y": -122.45552215649514, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ce404489-b775-486b-9379-a30c801f6f94", "name": "p1rdt6268-p1rdt6276xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d29d0187-de06-4d15-97ce-b21f4a1f04fa"}}}}, {"uuid": "8012248e-cccf-438a-8364-34bcc51f62c8", "name": "", "x": 38.61623050711647, "y": -122.4548802311643, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "68d2e030-852f-44f6-9e02-d5587a1fc6a0", "name": "p1rdt6268-p1rdt6276x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8012248e-cccf-438a-8364-34bcc51f62c8"}}}}, {"uuid": "a176b6e8-4da7-46f4-9ac6-cced26eb5e19", "name": "", "x": 38.616457957404585, "y": -122.4575517341824, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "51eefb94-724e-4dfe-9823-0f6cf8f56101", "name": "p1rdt6278", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a176b6e8-4da7-46f4-9ac6-cced26eb5e19"}}}}, {"uuid": "cc466d34-d930-4734-9094-61f34464eca8", "name": "", "x": 38.61591934452827, "y": -122.45606254734442, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "315af04d-a032-43a8-a2da-b9e68fd21f39", "name": "p1rdt6276", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc466d34-d930-4734-9094-61f34464eca8"}}}}, {"uuid": "1f9d8fc5-698a-40b8-adc4-7b10d6df6183", "name": "", "x": 38.616039041002885, "y": -122.45805901946764, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1dd4f893-7921-41c3-9e9e-d33e3680a999", "name": "p1rdt6277", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1f9d8fc5-698a-40b8-adc4-7b10d6df6183"}}}}, {"uuid": "d1d13ad6-e94b-45fe-8357-d6f81f83b860", "name": "", "x": 38.61556885068546, "y": -122.45905436217652, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "699595d6-8e08-41b1-8c3a-2aef170bb5f7", "name": "p1rdt6269-p1rdt6277x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1d13ad6-e94b-45fe-8357-d6f81f83b860"}}}}, {"uuid": "36918a38-3551-4a37-9465-3fda5261e1f9", "name": "", "x": 38.58377814515449, "y": -122.50670177876174, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "70bad714-71c1-4341-ac40-76312417dd03", "name": "p1rdt6045lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "36918a38-3551-4a37-9465-3fda5261e1f9"}}}}, {"uuid": "9e1584f4-9724-4c9e-ac13-d6b255344a7e", "name": "", "x": 38.58357344171333, "y": -122.50663601797484, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cc71e486-4a44-466d-bc57-85591b269949", "name": "p1rlv12555", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9e1584f4-9724-4c9e-ac13-d6b255344a7e"}}}}, {"uuid": "451fea3b-acbb-4e8f-9fea-77a4fda7de34", "name": "", "x": 38.58366602224418, "y": -122.50744271243232, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9d830a1b-6971-4f4d-99bd-945e0785b5aa", "name": "p1rdt6052lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "451fea3b-acbb-4e8f-9fea-77a4fda7de34"}}}}, {"uuid": "659f553d-9923-4b22-86f3-a0526d8303ff", "name": "", "x": 38.583654744101715, "y": -122.507354817808, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "29476f95-f85b-4843-a847-3d9d99da3b74", "name": "p1rlv12567", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "659f553d-9923-4b22-86f3-a0526d8303ff"}}}}, {"uuid": "95152bb2-254c-4961-8510-d3ef791e29bc", "name": "", "x": 38.58176166095416, "y": -122.50864860767257, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d1c8eb9-7f79-49ad-9e93-6c7cdcc95e22", "name": "p1rdt8902lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "95152bb2-254c-4961-8510-d3ef791e29bc"}}}}, {"uuid": "81cdea77-c892-4abd-93bc-946ff7be1759", "name": "", "x": 38.58164914879979, "y": -122.50832144611942, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a02024b5-aa74-4e07-b043-a7a0e8b3e816", "name": "p1rlv19164", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "81cdea77-c892-4abd-93bc-946ff7be1759"}}}}, {"uuid": "309b639b-14c0-47a6-8c13-ad4e20b47956", "name": "", "x": 38.57552859055316, "y": -122.51515559102107, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c3f191ff-f8f2-4f13-af83-e67d1fdd366a", "name": "p1rdt6537lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "309b639b-14c0-47a6-8c13-ad4e20b47956"}}}}, {"uuid": "5cf221cf-25ef-476c-af52-9402540f80d9", "name": "", "x": 38.575486581492186, "y": -122.51516107668057, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fe1a5da7-bdac-46a6-ab32-addc4f02a296", "name": "p1rlv13720", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5cf221cf-25ef-476c-af52-9402540f80d9"}}}}, {"uuid": "b8957f06-0823-465f-8389-1f4b1f7e4316", "name": "", "x": 38.575576829321776, "y": -122.51521644999882, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "45aca6e5-a8ee-4f45-80f3-e227379d33af", "name": "p1rdt6530-p1rdt6537x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b8957f06-0823-465f-8389-1f4b1f7e4316"}}}}, {"uuid": "af35ac47-262a-4419-82ab-afddde769dc1", "name": "", "x": 38.57557088455815, "y": -122.51515412712796, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "902291fa-9561-4f40-a4b7-4fd9fdded417", "name": "p1rdt6537", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "af35ac47-262a-4419-82ab-afddde769dc1"}}}}, {"uuid": "7cdaa1b9-0c0d-4944-9718-3cdadc5f131b", "name": "", "x": 38.56672395074998, "y": -122.5002666540795, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "41e61263-feb6-4264-965a-fd1309d997a1", "name": "p1rdt7313lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7cdaa1b9-0c0d-4944-9718-3cdadc5f131b"}}}}, {"uuid": "a5a69c8d-398f-44f6-a78a-cb55e8a7fb4d", "name": "", "x": 38.566682740186856, "y": -122.50025430587122, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "13eabcb1-332a-4c7a-8042-214ada721424", "name": "p1rlv15628", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a5a69c8d-398f-44f6-a78a-cb55e8a7fb4d"}}}}, {"uuid": "6dab9a69-1039-4816-bab2-3d238cf7bc4b", "name": "", "x": 38.566766241557346, "y": -122.50026502368816, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1a3a5e1c-77a2-4a9d-89e0-7d1c94176787", "name": "p1rdt7313", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6dab9a69-1039-4816-bab2-3d238cf7bc4b"}}}}, {"uuid": "44f035bc-740e-4f8c-86ee-3b2ed3b46052", "name": "", "x": 38.563855959465826, "y": -122.50868105587648, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f0c42b48-7ca4-465f-b17c-048cb5f6d79b", "name": "p1rdt7091lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "44f035bc-740e-4f8c-86ee-3b2ed3b46052"}}}}, {"uuid": "912aee73-148f-4e1f-af3c-8095f22549b6", "name": "", "x": 38.56387029221525, "y": -122.50873180728178, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "64634ab5-a5b0-45ae-9763-7d0be029350f", "name": "p1rlv15196", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "912aee73-148f-4e1f-af3c-8095f22549b6"}}}}, {"uuid": "3e40222f-8bb5-4b72-b0a8-3c1677f45386", "name": "", "x": 38.56720551439007, "y": -122.4954680905678, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f718935b-704d-4374-9172-856511e1eddd", "name": "p1rdt5658lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e40222f-8bb5-4b72-b0a8-3c1677f45386"}}}}, {"uuid": "e55dae49-706c-4edc-b323-1c5994e7842a", "name": "", "x": 38.56720030404839, "y": -122.4954147012043, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4747e0f3-2a66-4e5a-8160-ac0aabe34489", "name": "p1rlv11679", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e55dae49-706c-4edc-b323-1c5994e7842a"}}}}, {"uuid": "a496582f-3ab4-48b4-8bbe-9d948841118a", "name": "", "x": 38.56720668600247, "y": -122.49552196704039, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "81d6db26-881f-4cae-9514-df4c1e71c76e", "name": "p1rdt5658", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a496582f-3ab4-48b4-8bbe-9d948841118a"}}}}, {"uuid": "1e229978-bde6-49d6-88ef-a59ac7598fc7", "name": "", "x": 38.65216422809464, "y": -122.48679328426424, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0bab7e6b-74a6-4fe4-95e1-4ef96084f730", "name": "p1rdt5236-p1rdt8138x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1e229978-bde6-49d6-88ef-a59ac7598fc7"}}}}, {"uuid": "8e8eb4b7-82cc-4705-8d79-553180a38da3", "name": "", "x": 38.61289959602905, "y": -122.4594654458467, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "658514b3-59fd-44b7-95d6-a34cafcb47c5", "name": "p1rdt6270-p1rdt6271x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8e8eb4b7-82cc-4705-8d79-553180a38da3"}}}}, {"uuid": "cef73316-4e05-44ba-b446-d7d3a9c4fde4", "name": "", "x": 38.58084780242867, "y": -122.5096251869554, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c9938a5c-b1cd-4592-814d-324ff2eb6644", "name": "p1rdt6500-p1rdt6519x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cef73316-4e05-44ba-b446-d7d3a9c4fde4"}}}}, {"uuid": "10ccc3bc-3003-4ac7-b98e-a169941c9b43", "name": "", "x": 38.58086518694643, "y": -122.50946246615781, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "addd9f38-279f-4d9e-b216-38faef1940c7", "name": "p1rdt6519", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10ccc3bc-3003-4ac7-b98e-a169941c9b43"}}}}, {"uuid": "95e0e7cd-6529-4d7c-a009-4b5b33ed93ec", "name": "", "x": 38.58105786983961, "y": -122.50938072179505, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "acd6da90-895c-4d2c-80b4-1712b3949993", "name": "p1rdt6515-p1rdt6535x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "95e0e7cd-6529-4d7c-a009-4b5b33ed93ec"}}}}, {"uuid": "18ac8c15-27a3-4d77-af88-1d8055d5385e", "name": "", "x": 38.581060631396625, "y": -122.50954681794376, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b13053e-033e-4fe9-8eb3-89389e4bdc2b", "name": "p1rdt6535", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "18ac8c15-27a3-4d77-af88-1d8055d5385e"}}}}, {"uuid": "a4a67019-41da-4511-8cc7-c84f86f0e2b8", "name": "", "x": 38.58103206808594, "y": -122.50926637153142, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e0103161-4b16-4d25-a1f3-5a939317461f", "name": "p1rdt6515-p1rdt6536x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a4a67019-41da-4511-8cc7-c84f86f0e2b8"}}}}, {"uuid": "ba0629ba-5833-457a-b255-6ff9469bcdcf", "name": "", "x": 38.58096111560494, "y": -122.50912674534362, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8f5cda74-5e33-4c52-8b2c-76bcd5e6c5cb", "name": "p1rdt6536", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ba0629ba-5833-457a-b255-6ff9469bcdcf"}}}}, {"uuid": "ece0a614-8728-4152-bad4-c2f58d2cff06", "name": "", "x": 38.580843572870805, "y": -122.50968387919501, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "78b3b940-c277-441f-b2b3-83525ed85fcb", "name": "p1rdt6500", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ece0a614-8728-4152-bad4-c2f58d2cff06"}}}}, {"uuid": "a6631bf9-7546-47a7-b00b-9c15f3d90c15", "name": "", "x": 38.58105789188953, "y": -122.50931876846892, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f1537ab1-dc7c-4bbd-b347-fc740d54fcf7", "name": "p1rdt6515", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a6631bf9-7546-47a7-b00b-9c15f3d90c15"}}}}, {"uuid": "af42ea4f-a084-4c6c-9c59-95018e4fa65f", "name": "", "x": 38.58107734523138, "y": -122.50929094375307, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6ef5115d-ad7b-4671-b984-b9fd5969bf61", "name": "p1rdt6528", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "af42ea4f-a084-4c6c-9c59-95018e4fa65f"}}}}, {"uuid": "a3ccc5ea-84ec-45d4-9bc1-bd1015516736", "name": "", "x": 38.581426753801445, "y": -122.50903479519879, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9d887dbc-43bd-413e-8e72-5c95a2ed0be8", "name": "p1rdt8898", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a3ccc5ea-84ec-45d4-9bc1-bd1015516736"}}}}, {"uuid": "876c20e0-46d2-4171-bdcd-67bcae4f8a23", "name": "", "x": 38.581560713176216, "y": -122.50889655325749, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d9f12ed7-454c-4cc9-a631-377121a07ba5", "name": "p1rdt6532", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "876c20e0-46d2-4171-bdcd-67bcae4f8a23"}}}}, {"uuid": "549b0bcc-dd32-407b-a3ba-c7ee12c8c856", "name": "", "x": 38.5818039862915, "y": -122.50867642493746, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4f44ec9b-338a-4ae1-a26b-26422f218c13", "name": "p1rdt8902", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "549b0bcc-dd32-407b-a3ba-c7ee12c8c856"}}}}, {"uuid": "8ac7b79d-e22a-43be-ae62-480551b5dfe1", "name": "", "x": 38.58368183290747, "y": -122.50738908690626, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c10f182d-aa76-4633-9a84-f41e20b97da1", "name": "p1rdt6052", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8ac7b79d-e22a-43be-ae62-480551b5dfe1"}}}}, {"uuid": "58116fa8-1381-4b41-93df-1ced21da2f7f", "name": "", "x": 38.58371771254211, "y": -122.50730845553447, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "67bc3ce6-e23d-4899-b0e8-9783225338ff", "name": "p1rdt6046", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "58116fa8-1381-4b41-93df-1ced21da2f7f"}}}}, {"uuid": "bb9375da-bd01-4e61-94d0-a3db80a2f7d9", "name": "", "x": 38.58374436086863, "y": -122.50721642241469, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "87e05b2f-c346-452c-9c72-a6db090c3124", "name": "p1rdt6043", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bb9375da-bd01-4e61-94d0-a3db80a2f7d9"}}}}, {"uuid": "bf36148b-0b67-4e21-ba79-bb14f0d9b9a2", "name": "", "x": 38.613253340793605, "y": -122.45775080611988, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "632d8db5-5220-4188-94f0-f6131253820b", "name": "p1rdt6279", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bf36148b-0b67-4e21-ba79-bb14f0d9b9a2"}}}}, {"uuid": "3aa676ae-ebff-47f5-8913-13e464709b7d", "name": "", "x": 38.58052230427394, "y": -122.51054930766253, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "edf27f1d-b486-434e-92be-963bdeb26090", "name": "p1rdt6501-p1rdt9468x_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3aa676ae-ebff-47f5-8913-13e464709b7d"}}}}, {"uuid": "6eae70b0-8f38-48a1-8e62-c39823216437", "name": "", "x": 38.58140313016848, "y": -122.50982713555175, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e62ba05d-920f-4f55-b1c6-3aa078e0073d", "name": "p1rdt8902-p1rdt9377x_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6eae70b0-8f38-48a1-8e62-c39823216437"}}}}, {"uuid": "9cecf942-f125-4fc9-9f2d-23b443d58d44", "name": "", "x": 38.649913359314574, "y": -122.40176189052858, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8ccc9dcb-3a72-4f11-9bcf-e3a7f1a21985", "name": "p1rdt5195_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9cecf942-f125-4fc9-9f2d-23b443d58d44"}}}}, {"uuid": "54c5be93-4f2a-45c3-9b63-c3f7a44b0522", "name": "", "x": 38.68940056320115, "y": -122.44266975467744, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6b3c997d-cd47-439c-aeb9-326e12c2b869", "name": "p1rdt28lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "54c5be93-4f2a-45c3-9b63-c3f7a44b0522"}}}}, {"uuid": "14523271-bd86-41a7-aced-3e5e00efc0df", "name": "", "x": 38.68955085092013, "y": -122.44265311463495, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8ccef6af-4bf6-44dc-b292-2bf9503a374a", "name": "p1rlv51", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "14523271-bd86-41a7-aced-3e5e00efc0df"}}}}, {"uuid": "d1625529-9e08-4fbd-818b-487e4402e667", "name": "", "x": 38.689199515506125, "y": -122.44267883689947, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b3c62646-6132-41ef-ba14-a06789885cd5", "name": "p1rlv53", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1625529-9e08-4fbd-818b-487e4402e667"}}}}, {"uuid": "ab3986aa-349f-43ce-8609-e96791097421", "name": "", "x": 38.68719967792895, "y": -122.44202477655993, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "61fc3980-6aa4-415c-91c1-10d32c7c359c", "name": "p1rdt29lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ab3986aa-349f-43ce-8609-e96791097421"}}}}, {"uuid": "1232b5c1-d445-40db-859a-e61961a053ad", "name": "", "x": 38.68717368875977, "y": -122.44198213704887, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fec0a162-4b0c-4577-b878-8dbc7c9935fc", "name": "p1rlv52", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1232b5c1-d445-40db-859a-e61961a053ad"}}}}, {"uuid": "c345d1a1-14da-4a8c-a8bb-3e2c621c0204", "name": "", "x": 38.70237353390803, "y": -122.38204661340717, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4d2be3b5-dbfc-4099-af9a-96368e60fe23", "name": "p1rdt30lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c345d1a1-14da-4a8c-a8bb-3e2c621c0204"}}}}, {"uuid": "bc6d9158-f2b3-4cb0-9930-c6984365a7fc", "name": "", "x": 38.702248770449096, "y": -122.38177565760685, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "346dad85-3bf8-41a6-97ea-6b3b40a7f22e", "name": "p1rlv62", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bc6d9158-f2b3-4cb0-9930-c6984365a7fc"}}}}, {"uuid": "a7109162-f295-4719-8eaf-7cdf8aee7649", "name": "", "x": 38.70225996977785, "y": -122.382189570322, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c89ec162-cda3-4c40-8833-3fff085538ba", "name": "p1rdm56", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a7109162-f295-4719-8eaf-7cdf8aee7649"}}}}, {"uuid": "e4ce90f8-02a1-46dd-96c2-c7b8972e5363", "name": "", "x": 38.70215104431212, "y": -122.38204100448107, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "20010301-32ce-4cc0-ab59-04ef3bcd35d7", "name": "p1rlv54", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e4ce90f8-02a1-46dd-96c2-c7b8972e5363"}}}}, {"uuid": "e1200df2-4a75-4e15-8956-eaeb9ff30ccf", "name": "", "x": 38.70125472363682, "y": -122.37955319837823, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "59ff3c1b-38f4-4a33-86fa-e956951c0f2c", "name": "p1rdm58", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e1200df2-4a75-4e15-8956-eaeb9ff30ccf"}}}}, {"uuid": "a1fd30d9-7410-4c78-ba22-7372d3d81998", "name": "", "x": 38.701204180575694, "y": -122.37968411246109, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "36bdbc4e-edfa-425a-8e4c-e6123b567555", "name": "p1rlv55", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a1fd30d9-7410-4c78-ba22-7372d3d81998"}}}}, {"uuid": "4662f7a8-368e-4162-b872-3bc8f29531a6", "name": "", "x": 38.70120618742273, "y": -122.37889811298928, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f678ceb4-b717-44a5-9db9-f698bece6935", "name": "p1rdm60", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4662f7a8-368e-4162-b872-3bc8f29531a6"}}}}, {"uuid": "1b5b11ca-9f19-43b7-b13f-e7164ddc0619", "name": "", "x": 38.701314750425446, "y": -122.37897767463447, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25b891ce-797a-4a4d-b664-4225fba806c4", "name": "p1rlv152", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1b5b11ca-9f19-43b7-b13f-e7164ddc0619"}}}}, {"uuid": "833f8c3b-2661-4791-8f47-042ec9e5cd7a", "name": "", "x": 38.70133109954647, "y": -122.37964493055146, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3510eedd-535c-4e58-b81e-c5ec09030479", "name": "p1rdt31lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "833f8c3b-2661-4791-8f47-042ec9e5cd7a"}}}}, {"uuid": "3acc2e31-a59c-40ed-95ee-1341730b1e49", "name": "", "x": 38.7016002020804, "y": -122.3801252205059, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3a0a4841-bf31-4498-98d9-115cc159981c", "name": "p1rdm59", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3acc2e31-a59c-40ed-95ee-1341730b1e49"}}}}, {"uuid": "d52a647b-da63-4a12-93c7-3e1012a0e903", "name": "", "x": 38.701475019236376, "y": -122.38031030323685, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a32ee184-f677-4333-b7ee-7bc30ab41467", "name": "p1rlv58", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d52a647b-da63-4a12-93c7-3e1012a0e903"}}}}, {"uuid": "a84c9fe6-6be3-4d57-b05a-1e617ace728e", "name": "", "x": 38.70278615488254, "y": -122.38061347297433, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e374d6d6-1e75-4808-b65a-c7033e1bd528", "name": "p1rdt32lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a84c9fe6-6be3-4d57-b05a-1e617ace728e"}}}}, {"uuid": "675a026f-8f3a-4d6a-b336-f2a97a0172d3", "name": "", "x": 38.70279286082068, "y": -122.38071294165577, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ec2c1edd-78b1-4436-85cc-2fbc7d880b87", "name": "p1rlv414", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "675a026f-8f3a-4d6a-b336-f2a97a0172d3"}}}}, {"uuid": "3435bd69-9f3b-43ca-98a0-ec2de3c18d97", "name": "", "x": 38.70248568513053, "y": -122.3805660873002, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cef7aa37-7ca0-4130-9bcd-1804a811245a", "name": "p1rdm61", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3435bd69-9f3b-43ca-98a0-ec2de3c18d97"}}}}, {"uuid": "4e71fca8-0890-4db7-be87-fe294459781e", "name": "", "x": 38.702478683531616, "y": -122.38094565722146, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4694811a-ba43-4c78-b957-5209b1d961e2", "name": "p1rlv56", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4e71fca8-0890-4db7-be87-fe294459781e"}}}}, {"uuid": "4854c4d7-5bd8-4724-af9a-4acd5b27e364", "name": "", "x": 38.70162164245257, "y": -122.38472111973375, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "065c8583-45e5-466c-b4c0-1c66bf970abe", "name": "p1rdt33lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4854c4d7-5bd8-4724-af9a-4acd5b27e364"}}}}, {"uuid": "4199baea-30b5-43b2-b88c-0c1faf4aee21", "name": "", "x": 38.701985008267755, "y": -122.38473348273297, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0f7dbd18-1cbe-49d3-b490-3c46cf8e37f1", "name": "p1rlv170", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4199baea-30b5-43b2-b88c-0c1faf4aee21"}}}}, {"uuid": "78bbc070-dc8e-4410-8d4e-4f606565bf7c", "name": "", "x": 38.70159540402429, "y": -122.38433431596432, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b0538c66-18d7-440e-9efd-6b2945d50f2b", "name": "p1rdm63", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "78bbc070-dc8e-4410-8d4e-4f606565bf7c"}}}}, {"uuid": "fa50dadb-5ee3-46b3-a4eb-9ab06e3f7516", "name": "", "x": 38.70131629597425, "y": -122.38438270952352, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "925cb3b7-4ced-4a36-913f-e6851ed79b98", "name": "p1rlv57", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa50dadb-5ee3-46b3-a4eb-9ab06e3f7516"}}}}, {"uuid": "1d46a1cc-204e-4ea8-8397-e723f39f0b45", "name": "", "x": 38.70167064130821, "y": -122.38493167921865, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cfa2eaff-b163-46ce-b6e5-516680d39bc3", "name": "p1rdm64", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d46a1cc-204e-4ea8-8397-e723f39f0b45"}}}}, {"uuid": "7e6bb48b-c23f-44a8-978e-196d3e00c442", "name": "", "x": 38.70145424916845, "y": -122.38491053257476, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d22bf2f5-74cc-47c7-ae3b-410fba27c113", "name": "p1rlv61", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7e6bb48b-c23f-44a8-978e-196d3e00c442"}}}}, {"uuid": "0bcbb846-2e59-45fb-83c2-51c537155626", "name": "", "x": 38.7023106935151, "y": -122.37870903978225, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "72ee0111-4849-4280-b3c9-c0627d1a6c09", "name": "p1rdm66", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0bcbb846-2e59-45fb-83c2-51c537155626"}}}}, {"uuid": "4825661b-6b25-4827-b894-da341ab1f2d2", "name": "", "x": 38.7024768400754, "y": -122.37889862189955, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b80bdb24-4bbf-4a57-bd5f-6a5ec9d484dd", "name": "p1rlv59", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4825661b-6b25-4827-b894-da341ab1f2d2"}}}}, {"uuid": "363693fc-8724-4e30-9695-ca77f5fdac20", "name": "", "x": 38.70222160936453, "y": -122.37888535297411, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "553a6868-acec-4492-a52d-5aa08414c612", "name": "p1rdt34lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "363693fc-8724-4e30-9695-ca77f5fdac20"}}}}, {"uuid": "236fb449-47ee-42e4-993c-3997b0af760e", "name": "", "x": 38.70217983407473, "y": -122.37897019250839, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "713c1538-ceb4-46df-a996-6c591c0f8e40", "name": "p1rdm67", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "236fb449-47ee-42e4-993c-3997b0af760e"}}}}, {"uuid": "8587aa60-c8a0-494d-8deb-56c4d60053f5", "name": "", "x": 38.70224401225384, "y": -122.37917664191762, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "64a67ed2-a563-4378-b6ac-d9a95339e862", "name": "p1rlv67", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8587aa60-c8a0-494d-8deb-56c4d60053f5"}}}}, {"uuid": "a4d2bd60-6cec-4e24-9421-7fcc9429131d", "name": "", "x": 38.701765866802305, "y": -122.38301785787249, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f98cc066-fca3-4489-9770-047caee3e742", "name": "p1rdt35lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a4d2bd60-6cec-4e24-9421-7fcc9429131d"}}}}, {"uuid": "afa28b82-3110-4dbb-add6-0fa5d3d6fb16", "name": "", "x": 38.701398104123946, "y": -122.38280649214893, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7eb0d1e8-f85e-493e-b69b-26437fdb8ad9", "name": "p1rlv60", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "afa28b82-3110-4dbb-add6-0fa5d3d6fb16"}}}}, {"uuid": "8a2dda54-7737-47d5-82f8-ae2431bf65a0", "name": "", "x": 38.7018668128423, "y": -122.38282546368364, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "23861598-ab3c-4648-9de9-3ee4316f2cb4", "name": "p1rdm69", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8a2dda54-7737-47d5-82f8-ae2431bf65a0"}}}}, {"uuid": "9e951376-bb88-44f2-a35f-e171716fdd96", "name": "", "x": 38.701495649868505, "y": -122.3825066502607, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3e00fd9b-92b3-49c4-bcc2-957b9d2c7bad", "name": "p1rlv65", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9e951376-bb88-44f2-a35f-e171716fdd96"}}}}, {"uuid": "84576a85-50a9-45c2-ab04-9bd1cad70427", "name": "", "x": 38.701815325965796, "y": -122.38044139197483, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6a4fb658-c3ba-428a-82bf-b38ae68dd908", "name": "p1rdt36lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "84576a85-50a9-45c2-ab04-9bd1cad70427"}}}}, {"uuid": "38e99712-7679-4054-95fa-2634f8c37d8a", "name": "", "x": 38.701925218075054, "y": -122.38023741663469, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8300f90c-9a3b-400d-af04-072125dce84f", "name": "p1rlv63", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "38e99712-7679-4054-95fa-2634f8c37d8a"}}}}, {"uuid": "5f6775b3-6eb9-4eae-a0a4-44ca49b16b7e", "name": "", "x": 38.70179061086173, "y": -122.38718468697783, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "074f23bd-2fb2-4480-ae4b-f1c1f754613e", "name": "p1rdm71", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5f6775b3-6eb9-4eae-a0a4-44ca49b16b7e"}}}}, {"uuid": "9a15968a-34bf-40cb-9cbf-7467e5fd4b46", "name": "", "x": 38.70156139001374, "y": -122.38697566423983, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5efd07ee-012a-40a4-97bb-07c1a5ed898c", "name": "p1rlv64", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9a15968a-34bf-40cb-9cbf-7467e5fd4b46"}}}}, {"uuid": "96e3b526-172d-4c2c-aefc-89b5cea154dc", "name": "", "x": 38.7020086293725, "y": -122.38751633252258, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "590e467f-47a6-4c7e-ae3a-83cec8dd87e3", "name": "p1rdm72", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "96e3b526-172d-4c2c-aefc-89b5cea154dc"}}}}, {"uuid": "0997e9e0-7e96-449d-bbc7-a790b2928a00", "name": "", "x": 38.7022335504919, "y": -122.38744541239329, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3fcd1ee-e6e0-4ca3-aacf-cc527b07482a", "name": "p1rlv162", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0997e9e0-7e96-449d-bbc7-a790b2928a00"}}}}, {"uuid": "437cad19-f247-4f11-a9b0-8298d9bda0d4", "name": "", "x": 38.701696448473875, "y": -122.3875919728995, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "90a16370-67f7-4abd-992c-990d1eb8f17e", "name": "p1rdt37lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "437cad19-f247-4f11-a9b0-8298d9bda0d4"}}}}, {"uuid": "e106eb24-7a01-47e1-a694-69754915affd", "name": "", "x": 38.7014985369188, "y": -122.38819919157115, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35807695-5d6d-4544-a748-a96c56b705d1", "name": "p1rdm73", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e106eb24-7a01-47e1-a694-69754915affd"}}}}, {"uuid": "626c124b-2053-457c-ab89-54c6053f1645", "name": "", "x": 38.701670353304884, "y": -122.38831272923629, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6278f6ee-7332-4de8-9d2c-83bb637f489f", "name": "p1rlv457", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "626c124b-2053-457c-ab89-54c6053f1645"}}}}, {"uuid": "5493f5af-7894-49fc-9333-23343effb6c7", "name": "", "x": 38.70178443656836, "y": -122.37918061552492, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "352f8404-f923-468a-92a5-1be2f82ffb97", "name": "p1rdm74", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5493f5af-7894-49fc-9333-23343effb6c7"}}}}, {"uuid": "421b72f0-1f89-4f6c-a02b-5fd568cf930e", "name": "", "x": 38.701833201230905, "y": -122.37934517294276, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e90eb8a2-5db0-4861-96ef-a6991a0386eb", "name": "p1rlv66", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "421b72f0-1f89-4f6c-a02b-5fd568cf930e"}}}}, {"uuid": "33e19b23-b8c7-42b8-babb-ef9a8fd5ed1a", "name": "", "x": 38.701967149573, "y": -122.37911401099093, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "752aca33-7682-4e8c-a8b1-624467e02958", "name": "p1rdt38lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "33e19b23-b8c7-42b8-babb-ef9a8fd5ed1a"}}}}, {"uuid": "4c76e541-3e5a-43d7-aaa5-8196b790733b", "name": "", "x": 38.70235732979096, "y": -122.37866677526797, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2332f175-22ca-4894-b63d-246f5c11c572", "name": "p1rdm75", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c76e541-3e5a-43d7-aaa5-8196b790733b"}}}}, {"uuid": "f32f7bc5-6f90-4089-bec7-957167f1b819", "name": "", "x": 38.70211516673608, "y": -122.37867174586772, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c22aa2c8-a6fc-4b27-a875-e07e3f50ecac", "name": "p1rlv68", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f32f7bc5-6f90-4089-bec7-957167f1b819"}}}}, {"uuid": "da3b2612-960a-4760-b9db-3d1126101c02", "name": "", "x": 38.70178670019972, "y": -122.38549505637238, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "131099af-6f69-4531-bebf-e457ff5d7624", "name": "p1rdm76", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "da3b2612-960a-4760-b9db-3d1126101c02"}}}}, {"uuid": "c4fc819d-a932-4943-a7a8-b0008212d9bb", "name": "", "x": 38.701430782199786, "y": -122.38558924083848, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "876ffb0b-f33c-45b2-a085-7b34103ecffc", "name": "p1rlv69", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c4fc819d-a932-4943-a7a8-b0008212d9bb"}}}}, {"uuid": "0c79e619-8b46-4eb9-bbc3-ee2b7d368108", "name": "", "x": 38.701700119673376, "y": -122.38533518862636, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "623ec6b4-cb70-4437-9d79-5ec577bc3199", "name": "p1rdt39lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0c79e619-8b46-4eb9-bbc3-ee2b7d368108"}}}}, {"uuid": "8d15705c-b29e-458e-bd87-cc5cf3dbeb93", "name": "", "x": 38.70169870333672, "y": -122.38512694165256, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a909c826-1682-47f0-926c-0a67c9ff2a3a", "name": "p1rdm77", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8d15705c-b29e-458e-bd87-cc5cf3dbeb93"}}}}, {"uuid": "64ec693c-962c-4b4a-9a29-91692e5a3162", "name": "", "x": 38.701429210818716, "y": -122.38529025109813, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e53e7714-06d1-4f85-89c5-f152629e8ab7", "name": "p1rlv70", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "64ec693c-962c-4b4a-9a29-91692e5a3162"}}}}, {"uuid": "2e095ced-7dff-4118-9fbf-14b823e34b71", "name": "", "x": 38.6940139373904, "y": -122.37587462456409, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0d08444c-79a3-4ba0-8c69-1855a600dea0", "name": "p1rdt40lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2e095ced-7dff-4118-9fbf-14b823e34b71"}}}}, {"uuid": "0528c2c9-59dc-445a-bef7-3c20da20571c", "name": "", "x": 38.694063719222605, "y": -122.37569816102457, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "46cd88d0-b2c4-492a-af3d-d9ae886d0089", "name": "p1rlv143", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0528c2c9-59dc-445a-bef7-3c20da20571c"}}}}, {"uuid": "8b6a46f9-678f-4bdb-a630-5ce3f058dd3c", "name": "", "x": 38.69389087842103, "y": -122.37592566558304, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "435b1814-b0a6-40e3-a446-efe5b7fce133", "name": "p1rdm78", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8b6a46f9-678f-4bdb-a630-5ce3f058dd3c"}}}}, {"uuid": "a236f6f0-a10f-4bf6-a548-7064bf59a629", "name": "", "x": 38.69394647992354, "y": -122.3762126554526, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d7791de-0cf6-4901-8b95-2d67870f09f5", "name": "p1rlv71", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a236f6f0-a10f-4bf6-a548-7064bf59a629"}}}}, {"uuid": "f171115a-d335-42de-bb3e-cf5763cbcfa4", "name": "", "x": 38.69007704448215, "y": -122.37273530129958, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "793d0bf4-4d9f-4df4-bc95-d528dd7d31d5", "name": "p1rdt41lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f171115a-d335-42de-bb3e-cf5763cbcfa4"}}}}, {"uuid": "856fb6a1-3188-4dd5-8c7a-893d5944fa36", "name": "", "x": 38.68993682745413, "y": -122.37294747048301, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fc710fc3-ae5f-478e-997b-85467db7c93c", "name": "p1rlv72", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "856fb6a1-3188-4dd5-8c7a-893d5944fa36"}}}}, {"uuid": "a8e4f13a-5f5a-476e-b077-18b4f9da8bd1", "name": "", "x": 38.69017871415686, "y": -122.37268089773576, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "188047cd-3f14-4240-91fe-30113d48152b", "name": "p1rlv88", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8e4f13a-5f5a-476e-b077-18b4f9da8bd1"}}}}, {"uuid": "f760aebd-d2f9-4cdb-b451-2aba7e341a70", "name": "", "x": 38.69058527350743, "y": -122.3740266335316, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8fb27dc9-b404-49d1-84dd-0cde418b037d", "name": "p1rdt42lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f760aebd-d2f9-4cdb-b451-2aba7e341a70"}}}}, {"uuid": "cc1fe186-7eff-40cc-9087-6a08b3f0ffe7", "name": "", "x": 38.69045558452261, "y": -122.37389730590256, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "540e0121-fc39-4c2c-9fbc-012c020f5994", "name": "p1rlv86", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc1fe186-7eff-40cc-9087-6a08b3f0ffe7"}}}}, {"uuid": "d3dae137-37c2-4439-a8f7-287d04577a69", "name": "", "x": 38.690475022656685, "y": -122.3741615988237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c5f4300c-037f-42b5-a390-31ec1e8396b3", "name": "p1rdm82", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d3dae137-37c2-4439-a8f7-287d04577a69"}}}}, {"uuid": "ef7eaa33-52e1-434c-ab86-e12bd472fcf6", "name": "", "x": 38.69028492385651, "y": -122.37400227840031, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f4e2991c-1404-44da-bbb5-5a2ebc43bde4", "name": "p1rlv73", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef7eaa33-52e1-434c-ab86-e12bd472fcf6"}}}}, {"uuid": "9138a962-fd56-4f0f-8b21-acd66f15530f", "name": "", "x": 38.69038564798742, "y": -122.37430035768564, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5696ebea-257d-4cc1-9ae4-61c98563b706", "name": "p1rdm86", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9138a962-fd56-4f0f-8b21-acd66f15530f"}}}}, {"uuid": "dbb08176-39c0-4dbc-bf74-460d00d2f441", "name": "", "x": 38.690005204334135, "y": -122.37393572632347, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "afc70b80-ab76-440c-b05b-149458051675", "name": "p1rlv108", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dbb08176-39c0-4dbc-bf74-460d00d2f441"}}}}, {"uuid": "493507a6-2031-493a-ad6b-ef369cb0a201", "name": "", "x": 38.690672040311505, "y": -122.37392991440464, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "49a07eb5-9c9b-479c-a345-b09f72725a21", "name": "p1rdm83", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "493507a6-2031-493a-ad6b-ef369cb0a201"}}}}, {"uuid": "2233f4a7-d806-4388-900b-9d41df1e287d", "name": "", "x": 38.69071765074636, "y": -122.37403300248825, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0ef51371-3fa2-400a-a2b4-3afa97ff2419", "name": "p1rlv75", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2233f4a7-d806-4388-900b-9d41df1e287d"}}}}, {"uuid": "021c8fa6-1ab5-4a3b-b913-398dd6563305", "name": "", "x": 38.69090781102859, "y": -122.374203821834, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c5c96953-6710-4765-b5bd-4359e03e4c63", "name": "p1rlv130", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "021c8fa6-1ab5-4a3b-b913-398dd6563305"}}}}, {"uuid": "04e8ac20-3f95-4330-ad5d-f2b52e4280e4", "name": "", "x": 38.690788633118785, "y": -122.37382541248327, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ae45c08d-f629-4ff9-9c23-838b6e34da88", "name": "p1rdm84", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "04e8ac20-3f95-4330-ad5d-f2b52e4280e4"}}}}, {"uuid": "a8c38f40-05f1-4874-8046-4003ead1c4b8", "name": "", "x": 38.69085275864737, "y": -122.37402032667815, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e4dd2283-6100-48ce-b4bc-0e37b7b4e409", "name": "p1rlv79", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8c38f40-05f1-4874-8046-4003ead1c4b8"}}}}, {"uuid": "6c2fe5a3-78de-415f-9829-d2fa73ee39cb", "name": "", "x": 38.6908423930519, "y": -122.37376745173289, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d93360fa-3106-4444-9488-e73c6997ab71", "name": "p1rdm87", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c2fe5a3-78de-415f-9829-d2fa73ee39cb"}}}}, {"uuid": "59650fe8-d7a3-4405-94bf-13ea9d2f0b8e", "name": "", "x": 38.69085830065978, "y": -122.37390131828276, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "919a48e8-b378-4dd5-8e33-a2602fb58bc0", "name": "p1rlv115", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59650fe8-d7a3-4405-94bf-13ea9d2f0b8e"}}}}, {"uuid": "ca498dfc-d663-4237-a8fa-b38fa64f72e5", "name": "", "x": 38.6907528455112, "y": -122.37219295067007, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b812c54c-1689-47cf-beba-55faea943380", "name": "p1rdm90", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ca498dfc-d663-4237-a8fa-b38fa64f72e5"}}}}, {"uuid": "3eae7d71-071a-434a-936e-6fdec158239c", "name": "", "x": 38.69077167044301, "y": -122.37234226546438, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8e6de569-7f61-439e-a402-850c4f071ab3", "name": "p1rlv117", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3eae7d71-071a-434a-936e-6fdec158239c"}}}}, {"uuid": "0268316d-2bf7-483d-9aa8-55b9a7921399", "name": "", "x": 38.69123428534169, "y": -122.37237669444208, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "274aa0ec-f229-454c-b52d-23130bacb97e", "name": "p1rdt43lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0268316d-2bf7-483d-9aa8-55b9a7921399"}}}}, {"uuid": "3c4120d9-5325-4f01-8812-99a68d778116", "name": "", "x": 38.69134864004529, "y": -122.37238321787136, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0c82df28-72fa-4cf0-a844-8a6bf90e548b", "name": "p1rdm91", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3c4120d9-5325-4f01-8812-99a68d778116"}}}}, {"uuid": "4b05856f-25b9-4d86-8769-f887c528efb3", "name": "", "x": 38.691310990079565, "y": -122.37208458594603, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "54ca5205-5b71-42f2-8e24-c24f768a7a5c", "name": "p1rlv137", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4b05856f-25b9-4d86-8769-f887c528efb3"}}}}, {"uuid": "e736d97a-899f-460c-8076-87e1284f06d6", "name": "", "x": 38.69147492155732, "y": -122.37240511152062, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "acbf36c3-9c53-417f-98c1-fa1b5d4b60f4", "name": "p1rdm89", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e736d97a-899f-460c-8076-87e1284f06d6"}}}}, {"uuid": "36cb466e-9a0d-404d-bb08-cbf2ab13e1cf", "name": "", "x": 38.69153009984452, "y": -122.37261160297146, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5861410e-9d6d-423e-b967-2f2af65610b8", "name": "p1rlv74", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "36cb466e-9a0d-404d-bb08-cbf2ab13e1cf"}}}}, {"uuid": "66056a0b-621e-4e55-bd59-a4d2a449b4ab", "name": "", "x": 38.68938630771864, "y": -122.37020536032335, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c813f8a2-226b-431d-a41a-195cf5e8b01a", "name": "p1rdt44lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "66056a0b-621e-4e55-bd59-a4d2a449b4ab"}}}}, {"uuid": "4d54cf4d-36c1-4945-87e0-3fd1a67d9930", "name": "", "x": 38.68939678035235, "y": -122.37025840439561, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3354497f-6de7-405d-9fca-a9c77463dc27", "name": "p1rlv76", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d54cf4d-36c1-4945-87e0-3fd1a67d9930"}}}}, {"uuid": "e60fd94a-3e00-42ec-9121-2277b286d677", "name": "", "x": 38.690057823403926, "y": -122.37534955818452, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a5151d03-c8b3-41f2-a2cd-743aa8ea0fea", "name": "p1rdm93", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e60fd94a-3e00-42ec-9121-2277b286d677"}}}}, {"uuid": "6aa6e8f9-2731-4404-98c5-2d662c4bad90", "name": "", "x": 38.690220088213884, "y": -122.37535964547071, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f88a22a3-7e6c-4fc5-a8f4-a08cdaa3f5d6", "name": "p1rlv77", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6aa6e8f9-2731-4404-98c5-2d662c4bad90"}}}}, {"uuid": "eb9baf82-ce99-4bd0-b3d6-0bd99fd767c6", "name": "", "x": 38.68996899986402, "y": -122.37559179451463, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4dece5f0-ab6c-40ed-9ec6-0b1377d19e78", "name": "p1rdm94", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eb9baf82-ce99-4bd0-b3d6-0bd99fd767c6"}}}}, {"uuid": "e0a75be7-9eaf-4cdf-895a-1fe48b985539", "name": "", "x": 38.69013175574531, "y": -122.37569386454011, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ee33d90b-2f70-4c9d-863d-6486b95280b8", "name": "p1rlv119", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e0a75be7-9eaf-4cdf-895a-1fe48b985539"}}}}, {"uuid": "f33811d4-8e5e-4b75-98e4-e9e3ee105acd", "name": "", "x": 38.69009885909427, "y": -122.37512675776652, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e276abc-bb27-47e4-9de8-adaccbf964dd", "name": "p1rdt45lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f33811d4-8e5e-4b75-98e4-e9e3ee105acd"}}}}, {"uuid": "68d8f819-82c6-4f68-9d22-add5ca1a825e", "name": "", "x": 38.690225535592255, "y": -122.37469269533909, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a363b9b6-b80f-42cf-942e-17e723376ae6", "name": "p1rdm95", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "68d8f819-82c6-4f68-9d22-add5ca1a825e"}}}}, {"uuid": "1a0ff510-44f5-4e40-bac9-94d0f3d35467", "name": "", "x": 38.690035314507966, "y": -122.37451037852996, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "41960437-e2e6-4746-89c2-81c81602ca1b", "name": "p1rlv132", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1a0ff510-44f5-4e40-bac9-94d0f3d35467"}}}}, {"uuid": "c13588a5-fd65-4f01-ae00-29a3387c1182", "name": "", "x": 38.69396497728804, "y": -122.37461414459213, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2e93e7ed-6686-4fb2-8410-867f2cdbdab2", "name": "p1rdm96", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c13588a5-fd65-4f01-ae00-29a3387c1182"}}}}, {"uuid": "6c7ef76f-bde8-48eb-ad13-be3a39952c52", "name": "", "x": 38.69396985964566, "y": -122.37499754256292, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ae76f058-b79a-4c0f-90be-f9cd7a02bcfc", "name": "p1rlv78", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c7ef76f-bde8-48eb-ad13-be3a39952c52"}}}}, {"uuid": "05ef71ac-c109-4339-afed-73fc1b83ea7f", "name": "", "x": 38.694118107766265, "y": -122.3746013122857, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fdd576f2-a7e2-46eb-b2b0-818c4a97e694", "name": "p1rdm97", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "05ef71ac-c109-4339-afed-73fc1b83ea7f"}}}}, {"uuid": "c48aa8da-1798-4362-b5b7-73a858fb724c", "name": "", "x": 38.69415593578412, "y": -122.37493445252295, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "46ee0e6c-daf7-4412-94a7-5332a6a97656", "name": "p1rlv87", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c48aa8da-1798-4362-b5b7-73a858fb724c"}}}}, {"uuid": "b54fc4bd-352b-4d49-b123-d8ec37be6db1", "name": "", "x": 38.69382389629988, "y": -122.3746653446421, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aacdcb46-43e3-4147-ac25-3a9c1223e13a", "name": "p1rdt46lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b54fc4bd-352b-4d49-b123-d8ec37be6db1"}}}}, {"uuid": "e2d6efe2-38ba-4c3b-b704-9868be4eaae7", "name": "", "x": 38.69332609771847, "y": -122.37479218972346, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "70024d6c-94dd-4367-aeec-92d4bc5eec04", "name": "p1rdm98", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e2d6efe2-38ba-4c3b-b704-9868be4eaae7"}}}}, {"uuid": "948b06e4-a51d-4cd8-9bbb-9811f9996cee", "name": "", "x": 38.69336355649941, "y": -122.37505633665255, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ea9e5f8c-8477-403c-9d3a-911c4e5ab5c8", "name": "p1rlv138", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "948b06e4-a51d-4cd8-9bbb-9811f9996cee"}}}}, {"uuid": "f5d7283b-3a19-4218-880f-573c260dbb07", "name": "", "x": 38.69221243814819, "y": -122.3732880387573, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f031530a-b3fc-4f8e-b0ac-139009d1256c", "name": "p1rdt47lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5d7283b-3a19-4218-880f-573c260dbb07"}}}}, {"uuid": "9763b498-7e70-4ea0-9f4b-4bcd8a123c33", "name": "", "x": 38.692092560795636, "y": -122.3733081060302, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ab7e1b4a-f8ec-4211-b7a0-d7f9057f576a", "name": "p1rlv80", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9763b498-7e70-4ea0-9f4b-4bcd8a123c33"}}}}, {"uuid": "3ebad1dc-7b5d-4af3-8e2f-3e90cf714ce3", "name": "", "x": 38.69236265310078, "y": -122.37325975482375, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "db8f484a-94d5-4d20-8ebf-6708b1601a0d", "name": "p1rlv92", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3ebad1dc-7b5d-4af3-8e2f-3e90cf714ce3"}}}}, {"uuid": "29dc9d0c-aa67-46c7-9211-3b7d980cf123", "name": "", "x": 38.69245991415173, "y": -122.3717601018108, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2f1790fe-a399-46e3-b9e3-5979837777ce", "name": "p1rdt48lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "29dc9d0c-aa67-46c7-9211-3b7d980cf123"}}}}, {"uuid": "74ea0e90-f021-45c2-985c-a3cb88385ae9", "name": "", "x": 38.69259843146321, "y": -122.37185485582063, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ef92e40c-fe3c-4f7f-b844-884e1079e491", "name": "p1rlv81", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "74ea0e90-f021-45c2-985c-a3cb88385ae9"}}}}, {"uuid": "ed97c978-5fd5-4907-ba53-bcb6fa43fb14", "name": "", "x": 38.69231864911266, "y": -122.37177681198607, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a02925cd-7c5b-475f-9e91-30d639bb3c33", "name": "p1rlv120", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ed97c978-5fd5-4907-ba53-bcb6fa43fb14"}}}}, {"uuid": "7335310a-682c-4c5b-b04f-96fb5d0bacdd", "name": "", "x": 38.6924795549249, "y": -122.37153393231236, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fd7286c0-4c57-435f-bed2-fd9a927de8cc", "name": "p1rdm103", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7335310a-682c-4c5b-b04f-96fb5d0bacdd"}}}}, {"uuid": "240896b9-48a3-485b-afb2-209b3f5be2ac", "name": "", "x": 38.69255749370678, "y": -122.3714717809419, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4b02739e-d082-4c54-8deb-8ccc83ab82ab", "name": "p1rlv122", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "240896b9-48a3-485b-afb2-209b3f5be2ac"}}}}, {"uuid": "ed627fe4-0241-47e2-8e66-d0911edf3483", "name": "", "x": 38.693056440809926, "y": -122.37376716989863, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1e5bcc7e-f35c-4bbf-a7ff-a82817488b11", "name": "p1rdt49lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ed627fe4-0241-47e2-8e66-d0911edf3483"}}}}, {"uuid": "9c7705ad-1ce1-4efa-8baa-ac126fb5596d", "name": "", "x": 38.69309336879344, "y": -122.37340286288783, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "da2538bd-189b-4699-823b-ed459d94b422", "name": "p1rlv146", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9c7705ad-1ce1-4efa-8baa-ac126fb5596d"}}}}, {"uuid": "ff84e052-dc91-47d5-bf3f-d8465156a1f6", "name": "", "x": 38.693365493783084, "y": -122.37373395481842, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2409ced2-7817-40af-951f-33d725e9d75a", "name": "p1rdm104", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ff84e052-dc91-47d5-bf3f-d8465156a1f6"}}}}, {"uuid": "7fab99d1-39c7-4a67-a26a-a490bd18a53e", "name": "", "x": 38.69333125539768, "y": -122.3735427494079, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c3ddd704-2530-4392-8e9e-06e047b12f41", "name": "p1rlv82", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7fab99d1-39c7-4a67-a26a-a490bd18a53e"}}}}, {"uuid": "34c1c8cf-98d9-40f7-b221-800f7416fd25", "name": "", "x": 38.69285166538173, "y": -122.3737039387965, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a8385921-c183-4c26-bc99-bf5f0364c18b", "name": "p1rdm105", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "34c1c8cf-98d9-40f7-b221-800f7416fd25"}}}}, {"uuid": "559f04ef-a41b-4fc7-a97a-f8206ab479b3", "name": "", "x": 38.69285080314527, "y": -122.3735429639113, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "096e92a6-ea34-435e-a059-57d5234e1654", "name": "p1rlv107", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "559f04ef-a41b-4fc7-a97a-f8206ab479b3"}}}}, {"uuid": "af091acb-e936-456d-99d0-a49daa8431ea", "name": "", "x": 38.69316443073551, "y": -122.37605094152133, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8208c617-caa9-46a5-b28a-8a5b0d9898a2", "name": "p1rdt50lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "af091acb-e936-456d-99d0-a49daa8431ea"}}}}, {"uuid": "e529b33c-2b5c-4d79-84c2-a61b3b4aecc8", "name": "", "x": 38.69310634340839, "y": -122.3758289932297, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6ae7b1fe-08c4-4848-867e-e2426a325a99", "name": "p1rlv127", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e529b33c-2b5c-4d79-84c2-a61b3b4aecc8"}}}}, {"uuid": "f47c80f2-4d96-4104-a074-926b1622c44f", "name": "", "x": 38.69329674648888, "y": -122.37604581609166, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7948c980-abf7-4357-9ff8-4be9122a3167", "name": "p1rdm107", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f47c80f2-4d96-4104-a074-926b1622c44f"}}}}, {"uuid": "65d557de-e7d9-4492-96b2-9b1bf64cbb04", "name": "", "x": 38.69321156388965, "y": -122.37581260405913, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "24c3e8d8-1520-4a05-84af-a70da6140b4d", "name": "p1rlv83", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65d557de-e7d9-4492-96b2-9b1bf64cbb04"}}}}, {"uuid": "ff8cd1ac-4285-4784-8478-d357b8b3d1ce", "name": "", "x": 38.69331611852453, "y": -122.37629862181807, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6184fe8d-ae60-426a-8c0c-a3cc56c5b67e", "name": "p1rlv123", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ff8cd1ac-4285-4784-8478-d357b8b3d1ce"}}}}, {"uuid": "a9bb9f0a-c1ee-4814-8831-4afd88339097", "name": "", "x": 38.692999373711416, "y": -122.37604839940005, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c2deeb6a-3ea7-44d9-9ee0-b013733dadc4", "name": "p1rdm110", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a9bb9f0a-c1ee-4814-8831-4afd88339097"}}}}, {"uuid": "c03cc8c8-a4ae-4a69-bea0-b62060e3309c", "name": "", "x": 38.692941715957275, "y": -122.37590693919702, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cbdefe7a-517b-495b-88b8-dcf15a9429ff", "name": "p1rlv135", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c03cc8c8-a4ae-4a69-bea0-b62060e3309c"}}}}, {"uuid": "be69abca-c06f-493d-baf9-5ac7009a85d4", "name": "", "x": 38.692481049048034, "y": -122.37128492416231, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "09d7f030-a9b4-4705-82af-6cf140ba64d1", "name": "p1rdt51lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be69abca-c06f-493d-baf9-5ac7009a85d4"}}}}, {"uuid": "462dc74b-1c9a-44f1-a2d7-8681441fa9d6", "name": "", "x": 38.69252947996807, "y": -122.37076308321973, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "55e7538f-4bde-4810-a237-ac0cad7ba805", "name": "p1rlv84", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "462dc74b-1c9a-44f1-a2d7-8681441fa9d6"}}}}, {"uuid": "de0ee001-0810-4d03-9b34-91f9ab41b7cb", "name": "", "x": 38.6922695134408, "y": -122.37101833090937, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0060c029-188f-4725-a935-8d0d9cc892f7", "name": "p1rlv93", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "de0ee001-0810-4d03-9b34-91f9ab41b7cb"}}}}, {"uuid": "a39ff69c-ac92-4842-90cc-f3461b549300", "name": "", "x": 38.69210249623662, "y": -122.37348049869223, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a5dd2d9f-42d5-48c4-b1e1-34ae6aa555df", "name": "p1rdm113", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a39ff69c-ac92-4842-90cc-f3461b549300"}}}}, {"uuid": "90a4515d-a43d-4958-b510-8804455e348b", "name": "", "x": 38.69211341663018, "y": -122.37383686081611, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dcc52dd9-bacb-4e49-a057-d3747f89a7f7", "name": "p1rlv85", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "90a4515d-a43d-4958-b510-8804455e348b"}}}}, {"uuid": "3871a0c1-a5e7-4f51-9ba1-836ee2375900", "name": "", "x": 38.69236400854256, "y": -122.37351271362792, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f42789f3-35c3-4d0d-adda-2044adce92c0", "name": "p1rdm114", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3871a0c1-a5e7-4f51-9ba1-836ee2375900"}}}}, {"uuid": "96de4a8f-3d07-40c8-9322-a027d76c4048", "name": "", "x": 38.69234050594775, "y": -122.37364337983433, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6a1f01bc-d1f1-4d92-b1e2-1f8223624c52", "name": "p1rlv91", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "96de4a8f-3d07-40c8-9322-a027d76c4048"}}}}, {"uuid": "5f73ddf1-4313-4186-92b7-7545d7cb1de3", "name": "", "x": 38.691649262567026, "y": -122.37351497173694, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c70a7331-8c41-4370-b053-3eae432d52ae", "name": "p1rdt52lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5f73ddf1-4313-4186-92b7-7545d7cb1de3"}}}}, {"uuid": "8bbf286f-4457-45c4-a843-ea91d2a17f4d", "name": "", "x": 38.691390973585875, "y": -122.37355569590474, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d2d46cd2-9caf-47a7-b134-a29fccd91b9c", "name": "p1rdm115", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8bbf286f-4457-45c4-a843-ea91d2a17f4d"}}}}, {"uuid": "3cc3de65-5492-4f37-9a52-c57850ceb521", "name": "", "x": 38.691389371784915, "y": -122.37325674863969, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "db2d4080-1f43-47a3-9f3a-e25d1e4f5076", "name": "p1rlv94", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3cc3de65-5492-4f37-9a52-c57850ceb521"}}}}, {"uuid": "dc46f775-942e-4b57-a70e-ebee5a398f00", "name": "", "x": 38.69141053564886, "y": -122.3738429881131, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "85afc796-3fe5-4027-b84e-10d502124636", "name": "p1rlv103", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dc46f775-942e-4b57-a70e-ebee5a398f00"}}}}, {"uuid": "9f9870ad-18ce-4f8e-aafd-27e9a5ce0884", "name": "", "x": 38.691455037994594, "y": -122.373739113497, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4b7dbf54-f6bc-4e20-b2f3-8c63a44dd993", "name": "p1rlv144", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9f9870ad-18ce-4f8e-aafd-27e9a5ce0884"}}}}, {"uuid": "d1dd480a-e298-46fc-bde3-865df51decce", "name": "", "x": 38.69127394993667, "y": -122.37357971347488, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a0d6e82b-cba7-4c7e-8715-d73c3530bad7", "name": "p1rdm116", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1dd480a-e298-46fc-bde3-865df51decce"}}}}, {"uuid": "fd74d192-e637-48d7-8d35-d8fbaeb298f5", "name": "", "x": 38.691299813396455, "y": -122.37336101652306, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "82f19d5c-0941-411d-8baa-3ba029471dae", "name": "p1rlv98", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fd74d192-e637-48d7-8d35-d8fbaeb298f5"}}}}, {"uuid": "b6cdcfae-cff8-4e49-ad15-f9b8de0e80f3", "name": "", "x": 38.69128456220349, "y": -122.37387858172916, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b45d086e-8e0d-42f4-a8ec-6d3a9579a96b", "name": "p1rlv136", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b6cdcfae-cff8-4e49-ad15-f9b8de0e80f3"}}}}, {"uuid": "8ddc7d7f-da7a-419c-9197-b4d0540b8ba5", "name": "", "x": 38.69265743519212, "y": -122.37614335951521, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "329f78a6-af13-4ceb-bc87-4660d497c22e", "name": "p1rdm122", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8ddc7d7f-da7a-419c-9197-b4d0540b8ba5"}}}}, {"uuid": "10bc977a-803e-4f0f-ba15-de1ba41eb822", "name": "", "x": 38.69254776576972, "y": -122.37585684466497, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d3367cc2-b096-4cfb-ae71-038eb9e06b46", "name": "p1rlv125", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10bc977a-803e-4f0f-ba15-de1ba41eb822"}}}}, {"uuid": "ce535576-0e9b-4e7c-b655-cde66068e7df", "name": "", "x": 38.692649343871935, "y": -122.37631591047503, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aa8af0a4-4d55-41e4-83d1-4fe349920e38", "name": "p1rlv148", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ce535576-0e9b-4e7c-b655-cde66068e7df"}}}}, {"uuid": "911b88f2-844c-45e2-ae9a-b20256b0016c", "name": "", "x": 38.69275631408947, "y": -122.37609650577265, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8d595142-3854-4152-b64a-6cda8396a523", "name": "p1rdm121", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "911b88f2-844c-45e2-ae9a-b20256b0016c"}}}}, {"uuid": "c13e3655-f460-4dd1-aecb-af05f8e64a35", "name": "", "x": 38.69270022130948, "y": -122.3757175352468, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "66748ae6-b6ef-4228-bb0f-f9a121f0e1a3", "name": "p1rlv111", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c13e3655-f460-4dd1-aecb-af05f8e64a35"}}}}, {"uuid": "341b2db8-4359-479b-94c7-4683b22cf69d", "name": "", "x": 38.692882349552875, "y": -122.37607241348934, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e2e27276-ea6c-40a3-92d3-4648ec9d235d", "name": "p1rdm123", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "341b2db8-4359-479b-94c7-4683b22cf69d"}}}}, {"uuid": "6513d061-1878-4780-8a4f-3b4468228566", "name": "", "x": 38.692817981929934, "y": -122.37583149911002, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "499fb461-ccb6-436a-8078-eec9beffb4a9", "name": "p1rlv131", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6513d061-1878-4780-8a4f-3b4468228566"}}}}, {"uuid": "5305b25b-d732-4948-8e2a-120bdd4e9ee1", "name": "", "x": 38.69257937121657, "y": -122.37618250960169, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2536a0eb-a35c-40d4-9773-b78379e7481a", "name": "p1rdt53lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5305b25b-d732-4948-8e2a-120bdd4e9ee1"}}}}, {"uuid": "71836ddb-b0aa-495c-a6dd-453ad997e814", "name": "", "x": 38.69241474350349, "y": -122.3762604541736, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e9f62740-f47f-4c97-bae7-4380fe83fcbc", "name": "p1rdm124", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "71836ddb-b0aa-495c-a6dd-453ad997e814"}}}}, {"uuid": "0078fa0b-43fb-419f-bd42-e6fd99824e8f", "name": "", "x": 38.69237796229021, "y": -122.37612278955407, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eb69a6a9-3eaf-4fc3-82be-0eec77455a82", "name": "p1rlv141", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0078fa0b-43fb-419f-bd42-e6fd99824e8f"}}}}, {"uuid": "d7bb4578-cd1e-44b4-a117-fcfb149a76f4", "name": "", "x": 38.69212730175752, "y": -122.37643542970159, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d1071344-55a0-4684-9fbf-5729ec1f21c2", "name": "p1rdm120", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d7bb4578-cd1e-44b4-a117-fcfb149a76f4"}}}}, {"uuid": "f1b03aac-33b7-4dd4-9479-ae369e39696d", "name": "", "x": 38.692072620801916, "y": -122.37632091820853, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "24d75e9a-0249-48ca-ad10-32738bb6a519", "name": "p1rlv89", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f1b03aac-33b7-4dd4-9479-ae369e39696d"}}}}, {"uuid": "a53dd899-1fb1-46fd-b738-e94aa524e450", "name": "", "x": 38.690545533550726, "y": -122.37333707739843, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "57889d14-4aac-4aee-a9e2-677a047e8054", "name": "p1rdt54lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a53dd899-1fb1-46fd-b738-e94aa524e450"}}}}, {"uuid": "d58e8629-1002-48f1-8063-585740bce5a9", "name": "", "x": 38.690111985440346, "y": -122.3736818329642, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e06b2ac7-926e-4caf-afac-386910d4ea5e", "name": "p1rlv90", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d58e8629-1002-48f1-8063-585740bce5a9"}}}}, {"uuid": "e419a944-3cee-407a-af22-419361162c4c", "name": "", "x": 38.69031825985071, "y": -122.37349606102795, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4fe82ede-430d-454d-b9d0-e212d0621ea1", "name": "p1rlv105", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e419a944-3cee-407a-af22-419361162c4c"}}}}, {"uuid": "6f475d0a-f83e-4632-b565-29f42721ed71", "name": "", "x": 38.69409341663082, "y": -122.37388461682215, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "85ad3bf0-7e82-4e32-8106-faddcf725bdf", "name": "p1rdt56lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6f475d0a-f83e-4632-b565-29f42721ed71"}}}}, {"uuid": "20af2ea4-a9f6-4e7d-9cf0-b224359b9df0", "name": "", "x": 38.693962208985816, "y": -122.37409671723277, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "31508077-f731-47cb-94a9-869d7910e406", "name": "p1rlv96", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "20af2ea4-a9f6-4e7d-9cf0-b224359b9df0"}}}}, {"uuid": "a9937757-1991-4707-aad9-564a014df7a1", "name": "", "x": 38.694453827235925, "y": -122.37334499797639, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a60b127d-0530-495e-b3b9-2ebabf070fa1", "name": "p1rdm131", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a9937757-1991-4707-aad9-564a014df7a1"}}}}, {"uuid": "508ecc8e-1f06-4f5a-8b96-19bce68709b4", "name": "", "x": 38.69441870621642, "y": -122.37351778932282, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a11ba246-99d9-4cf5-a557-bec53c75e6fb", "name": "p1rlv804", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "508ecc8e-1f06-4f5a-8b96-19bce68709b4"}}}}, {"uuid": "c05965fd-98d6-49ab-b7ed-438036a0cab8", "name": "", "x": 38.69031197102896, "y": -122.37232328557447, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4bf5bf18-363d-4f4e-bf10-9ffc601c0f30", "name": "p1rdm133", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c05965fd-98d6-49ab-b7ed-438036a0cab8"}}}}, {"uuid": "16c92af6-c70a-4596-b4d0-70df593ccca4", "name": "", "x": 38.69039362804738, "y": -122.37242605719072, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bc4a448a-c6cb-4714-b8e6-b75bc6bc219c", "name": "p1rlv99", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "16c92af6-c70a-4596-b4d0-70df593ccca4"}}}}, {"uuid": "4c1aabbe-0b3e-4cb5-8d6c-f778f2aea5ba", "name": "", "x": 38.69048579257096, "y": -122.37227974908389, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e3367c40-9f47-42d9-b627-bc502b170f2a", "name": "p1rdt58lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c1aabbe-0b3e-4cb5-8d6c-f778f2aea5ba"}}}}, {"uuid": "d328a29f-ee37-4a80-a029-55b6cb1e5ea2", "name": "", "x": 38.69060891171015, "y": -122.37224020218359, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32e76273-c930-4506-9610-8cbfca04af67", "name": "p1rdm134", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d328a29f-ee37-4a80-a029-55b6cb1e5ea2"}}}}, {"uuid": "8a619225-2829-4897-911e-5c71a4d46e70", "name": "", "x": 38.69066464553883, "y": -122.37255017170527, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48d1be49-5aca-4e18-8b85-2a1274b3f26d", "name": "p1rlv101", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8a619225-2829-4897-911e-5c71a4d46e70"}}}}, {"uuid": "4e0e8d3c-7c65-411b-9610-d85c9d4654d5", "name": "", "x": 38.69344092722396, "y": -122.37604456356478, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a7b11b31-78f1-41fa-b511-df76daad0efc", "name": "p1rdm135", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4e0e8d3c-7c65-411b-9610-d85c9d4654d5"}}}}, {"uuid": "e138768b-008a-4552-b69b-4aa8538cf63a", "name": "", "x": 38.69344227667356, "y": -122.37629752630082, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "62a0d673-eaba-4032-9038-8095e2d53999", "name": "p1rlv100", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e138768b-008a-4552-b69b-4aa8538cf63a"}}}}, {"uuid": "fe421763-978a-4d59-8ddf-5f15b7e8f858", "name": "", "x": 38.69361499553134, "y": -122.37604702739569, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8aca9934-9439-4ce6-9ee3-475980324054", "name": "p1rdt59lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fe421763-978a-4d59-8ddf-5f15b7e8f858"}}}}, {"uuid": "1a258a18-33ff-49b6-af22-3f303a0cb210", "name": "", "x": 38.69374688178432, "y": -122.37596141343235, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a415176a-ddab-47a0-9ce7-54c53c4c0f11", "name": "p1rdm136", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1a258a18-33ff-49b6-af22-3f303a0cb210"}}}}, {"uuid": "20b67a46-6909-495f-95d4-ec7eeead6efe", "name": "", "x": 38.69371837494324, "y": -122.37568568791933, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0dbaab50-3abc-4207-82dc-5fcc5be68aad", "name": "p1rlv121", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "20b67a46-6909-495f-95d4-ec7eeead6efe"}}}}, {"uuid": "6ee52466-2ac9-43a0-afb5-55b532be96bf", "name": "", "x": 38.69088191916026, "y": -122.37220729684483, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d2517cea-05d3-4b7f-b9fc-0df0fde81235", "name": "p1rdt60lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6ee52466-2ac9-43a0-afb5-55b532be96bf"}}}}, {"uuid": "ebddd272-2642-4382-93c8-732a7e251cf7", "name": "", "x": 38.690940600905, "y": -122.3719153472003, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "06a432e3-dd37-4c52-b954-6652bb529c8e", "name": "p1rlv102", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ebddd272-2642-4382-93c8-732a7e251cf7"}}}}, {"uuid": "d34b3076-2883-4efd-a327-df823cfc09ce", "name": "", "x": 38.6914549432012, "y": -122.37540639973672, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e53344e0-e328-4acd-b159-e1f8cc246996", "name": "p1rdm138", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d34b3076-2883-4efd-a327-df823cfc09ce"}}}}, {"uuid": "65aeaed9-9c37-4058-be93-e0d605ed9fe2", "name": "", "x": 38.69137249020519, "y": -122.3751541495459, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c76c5b8f-1994-470c-a024-b97c73b9bb41", "name": "p1rlv104", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65aeaed9-9c37-4058-be93-e0d605ed9fe2"}}}}, {"uuid": "03b11a14-27fc-4ea8-843f-062716cd853d", "name": "", "x": 38.69120075557791, "y": -122.37558860981264, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "70f11a44-826f-45b8-9dc3-0f51ce6c9733", "name": "p1rdt61lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "03b11a14-27fc-4ea8-843f-062716cd853d"}}}}, {"uuid": "3143231f-7aee-4214-acd2-38fc402f9656", "name": "", "x": 38.69118822551713, "y": -122.37608712916376, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "022bda10-6b1a-408b-a231-adb63e189d14", "name": "p1rdm139", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3143231f-7aee-4214-acd2-38fc402f9656"}}}}, {"uuid": "13ab2b32-9d28-4487-81f1-93b0f2bdb41c", "name": "", "x": 38.691080519301316, "y": -122.37616855391688, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e5ca78b-6151-4a35-8a04-1bab215f0f10", "name": "p1rlv124", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "13ab2b32-9d28-4487-81f1-93b0f2bdb41c"}}}}, {"uuid": "8313fe5a-77d6-4a80-a7cd-5eef33ed7059", "name": "", "x": 38.693600768265796, "y": -122.37276202285804, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fac6d4e1-b14d-4973-9626-6a4bde2d2a42", "name": "p1rdt63lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8313fe5a-77d6-4a80-a7cd-5eef33ed7059"}}}}, {"uuid": "d428aee0-32db-49a7-b1b4-0ec78e144463", "name": "", "x": 38.69345061514859, "y": -122.37280180665408, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c76fc99c-c160-4ed0-85dd-ec3da962bb24", "name": "p1rlv109", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d428aee0-32db-49a7-b1b4-0ec78e144463"}}}}, {"uuid": "08ec40fb-604c-4457-9274-469a0579239f", "name": "", "x": 38.6932526134289, "y": -122.3728495309013, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25edc94b-a44b-4200-8cde-73941c2818b8", "name": "p1rlv112", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "08ec40fb-604c-4457-9274-469a0579239f"}}}}, {"uuid": "ed2e38b0-cdbf-45f9-9605-3518d40c2b3c", "name": "", "x": 38.69373045846697, "y": -122.37289135400576, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "21b14d95-6634-4f0e-a380-d5e57328d825", "name": "p1rdm143", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ed2e38b0-cdbf-45f9-9605-3518d40c2b3c"}}}}, {"uuid": "73fade0f-c897-4b49-8bd1-e189d59eef12", "name": "", "x": 38.69364972680421, "y": -122.37296105211496, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8b515111-3455-471a-aba8-92c82624a195", "name": "p1rlv139", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "73fade0f-c897-4b49-8bd1-e189d59eef12"}}}}, {"uuid": "b345efc1-ee77-4dc0-8990-db5453affdff", "name": "", "x": 38.6938583426107, "y": -122.37321220673307, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "09182ca9-8ea2-4d1c-9c3e-5850a77c1b66", "name": "p1rdm145", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b345efc1-ee77-4dc0-8990-db5453affdff"}}}}, {"uuid": "d8c833e7-f9ae-40b3-954e-fc43f94fe057", "name": "", "x": 38.69399264902756, "y": -122.37305004970418, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2756378a-0c67-47cf-969d-bdb9e55c8a4b", "name": "p1rlv113", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d8c833e7-f9ae-40b3-954e-fc43f94fe057"}}}}, {"uuid": "1fe742ec-1cfe-4dc9-bc90-282a353ece23", "name": "", "x": 38.69377761075648, "y": -122.37328190461031, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "56bc8935-c658-424c-83d8-0d13bf8d292a", "name": "p1rlv128", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1fe742ec-1cfe-4dc9-bc90-282a353ece23"}}}}, {"uuid": "4fc8e4df-cce5-4fd7-a029-1788d5853eb5", "name": "", "x": 38.694126443783816, "y": -122.37332088048717, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2ae9cb89-7cb8-48c6-a5bc-4178ee364ae8", "name": "p1rdt65lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4fc8e4df-cce5-4fd7-a029-1788d5853eb5"}}}}, {"uuid": "026d3939-bb21-4f6c-855c-b54a7898f18e", "name": "", "x": 38.694562147559466, "y": -122.3733785499152, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "de7551d6-5168-440c-8fe2-9f17e0904c29", "name": "p1rdm147", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "026d3939-bb21-4f6c-855c-b54a7898f18e"}}}}, {"uuid": "e11d221e-d445-4bf9-b913-3b02f6e74ea6", "name": "", "x": 38.69465084301279, "y": -122.37311329835559, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e7ffe87d-4424-4495-83c1-6765d385207c", "name": "p1rlv838", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e11d221e-d445-4bf9-b913-3b02f6e74ea6"}}}}, {"uuid": "9dfdfc2c-853e-4c2b-9385-252d60851f2d", "name": "", "x": 38.767616650522, "y": -122.38054158855523, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dfb9fa3b-c758-4c2e-bc51-f297b1ed21bf", "name": "p1rdt66lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9dfdfc2c-853e-4c2b-9385-252d60851f2d"}}}}, {"uuid": "2538c3eb-b1bc-4ee5-8b00-fa5f18ac8f48", "name": "", "x": 38.767590639077596, "y": -122.38049892417555, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d7934cd3-dcd6-4b67-8206-8a3636b6f75d", "name": "p1rlv114", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2538c3eb-b1bc-4ee5-8b00-fa5f18ac8f48"}}}}, {"uuid": "342627f1-23fc-4fc1-801a-3d315338bc32", "name": "", "x": 38.76719268838157, "y": -122.36058092984808, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bd2d6296-a302-4027-9e5f-c24a56a1a1ac", "name": "p1rdt68lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "342627f1-23fc-4fc1-801a-3d315338bc32"}}}}, {"uuid": "d877fb1b-68a6-4726-933b-8b5b97ff3748", "name": "", "x": 38.76717558814645, "y": -122.36126774194496, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "247e37b3-d6d0-41d7-a6b3-ee29d415da50", "name": "p1rlv118", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d877fb1b-68a6-4726-933b-8b5b97ff3748"}}}}, {"uuid": "da398a4c-6151-40cc-aced-2f61d4aa4fc6", "name": "", "x": 38.689974435374744, "y": -122.37228069359776, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7057debb-bd4d-4156-a253-0f3a14cdd784", "name": "p1rdt69lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "da398a4c-6151-40cc-aced-2f61d4aa4fc6"}}}}, {"uuid": "28269207-9ffd-447f-813e-276f53697dd2", "name": "", "x": 38.68985295036364, "y": -122.37243078084407, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c6c42586-4f46-45c6-910f-90fca771cfd2", "name": "p1rlv129", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "28269207-9ffd-447f-813e-276f53697dd2"}}}}, {"uuid": "750d9357-0219-4629-9238-6ea19caae837", "name": "", "x": 38.68983375524, "y": -122.37221248161097, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "47b7d9f8-ca72-4a77-af67-74ee561f7f10", "name": "p1rlv140", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "750d9357-0219-4629-9238-6ea19caae837"}}}}, {"uuid": "ef755cd7-5294-40c4-91c0-5cf1aacdfadb", "name": "", "x": 38.69318495516089, "y": -122.37483189069003, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "02440066-bc62-4629-96c5-4b497827de5b", "name": "p1rdt70lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef755cd7-5294-40c4-91c0-5cf1aacdfadb"}}}}, {"uuid": "35da9aa8-9637-4cb6-bec3-23001af4bfad", "name": "", "x": 38.69327375078167, "y": -122.3751146121051, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "31dc8280-eb14-4f87-85d7-8eae17013fe7", "name": "p1rlv133", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "35da9aa8-9637-4cb6-bec3-23001af4bfad"}}}}, {"uuid": "e492d455-8b95-4140-896e-122720e148d6", "name": "", "x": 38.69171296593506, "y": -122.37647352235795, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "43d5d2c5-10f6-4e89-91fa-5186f269b659", "name": "p1rdm155", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e492d455-8b95-4140-896e-122720e148d6"}}}}, {"uuid": "e65435ef-abb3-4ac1-89e5-c476f3b500f1", "name": "", "x": 38.69171223017465, "y": -122.37633554599886, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "425bdcfa-9753-4ef5-bb38-9e014ae779dc", "name": "p1rlv134", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e65435ef-abb3-4ac1-89e5-c476f3b500f1"}}}}, {"uuid": "23e3a742-b04c-4e8f-b57d-1ab749ef5509", "name": "", "x": 38.69147969326603, "y": -122.37638705727157, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e71f106d-4b41-405f-bce9-3d06b336a554", "name": "p1rdt71lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "23e3a742-b04c-4e8f-b57d-1ab749ef5509"}}}}, {"uuid": "7f986097-b809-478f-8770-78aac41b94ff", "name": "", "x": 38.69139677338097, "y": -122.37632678646379, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8357e543-eba0-4863-9d95-e34d84a3fae7", "name": "p1rdm156", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7f986097-b809-478f-8770-78aac41b94ff"}}}}, {"uuid": "7ee686cc-84ec-4ff3-9f8f-854f628ac999", "name": "", "x": 38.691395853444895, "y": -122.37615431677973, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1704e67-dfa3-4a6b-a3f4-7ebba9d27537", "name": "p1rlv145", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7ee686cc-84ec-4ff3-9f8f-854f628ac999"}}}}, {"uuid": "0431b8bc-cdf5-4f6e-b49c-eb912990b029", "name": "", "x": 38.69181140426288, "y": -122.37350205897214, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4b59eeab-d997-4186-ab59-0424644d5aeb", "name": "p1rdt72lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0431b8bc-cdf5-4f6e-b49c-eb912990b029"}}}}, {"uuid": "41d95e2a-ac27-4824-827e-3f927ed8ecc1", "name": "", "x": 38.6918879083499, "y": -122.37326787315344, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "070d9a60-c6f2-424c-bd0f-66c52d349f0c", "name": "p1rlv147", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "41d95e2a-ac27-4824-827e-3f927ed8ecc1"}}}}, {"uuid": "bcf6bf7b-ed30-4d11-94d5-a4e84b67a7c4", "name": "", "x": 38.70177173843472, "y": -122.38529743886787, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35f3fd4d-f962-4e4e-89d8-8b41a07ff57d", "name": "p1rdm158", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bcf6bf7b-ed30-4d11-94d5-a4e84b67a7c4"}}}}, {"uuid": "e036b17c-2c45-421a-a0ad-22e901b75472", "name": "", "x": 38.70192489270885, "y": -122.38529750774045, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "063e89ea-6dd0-404f-abfb-21686f3041ed", "name": "p1rlv149", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e036b17c-2c45-421a-a0ad-22e901b75472"}}}}, {"uuid": "dc1f28a1-6b0e-494c-9128-161bf7611a05", "name": "", "x": 38.701762667089824, "y": -122.38553586657494, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4f027d15-df82-4989-93e5-a3b40c862b08", "name": "p1rdt73lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dc1f28a1-6b0e-494c-9128-161bf7611a05"}}}}, {"uuid": "45cb53cc-d42e-45c1-8dea-12d137daf666", "name": "", "x": 38.7017739969935, "y": -122.38573580631073, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7b8d2667-d52b-46b3-ace4-2ad2b4e3050e", "name": "p1rdm159", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "45cb53cc-d42e-45c1-8dea-12d137daf666"}}}}, {"uuid": "ce5d58a5-24be-4e25-851b-2d3cc071d845", "name": "", "x": 38.70192743071094, "y": -122.38578049451348, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5187e006-621e-4c15-9604-0272ae62887c", "name": "p1rlv167", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ce5d58a5-24be-4e25-851b-2d3cc071d845"}}}}, {"uuid": "183e0605-103e-45e9-9163-63593da28942", "name": "", "x": 38.70203671550442, "y": -122.37747640223225, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bb4a799f-0e03-4ba6-b8ce-8f5e117fd2c2", "name": "p1rdm160", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "183e0605-103e-45e9-9163-63593da28942"}}}}, {"uuid": "b8296ec7-3cda-410c-8834-0221de56b03e", "name": "", "x": 38.70208317973028, "y": -122.37774050453031, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0b9979ec-4e43-4feb-a617-28191e9dd9d8", "name": "p1rlv150", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b8296ec7-3cda-410c-8834-0221de56b03e"}}}}, {"uuid": "9c87a630-51fc-447a-8893-3882b474b13b", "name": "", "x": 38.702169092358545, "y": -122.37748277827959, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "37880102-8a9c-4f7b-930a-b29a94241866", "name": "p1rdt74lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9c87a630-51fc-447a-8893-3882b474b13b"}}}}, {"uuid": "4e339b8e-d334-4e6e-b8b0-f354cfa78884", "name": "", "x": 38.70233414912363, "y": -122.37748532373683, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "243cdb10-5012-48b5-809f-1952913bf655", "name": "p1rdm161", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4e339b8e-d334-4e6e-b8b0-f354cfa78884"}}}}, {"uuid": "f5b304ee-ff90-4eae-9d5e-de243e25ae8c", "name": "", "x": 38.702308461860476, "y": -122.3777385521559, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0e326756-7ead-4099-a065-9f2de5693197", "name": "p1rlv169", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5b304ee-ff90-4eae-9d5e-de243e25ae8c"}}}}, {"uuid": "edb1309f-17be-473e-9536-b73605ba9cc7", "name": "", "x": 38.70182389972923, "y": -122.38611886200323, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "699bbf24-59ba-4dba-8bd4-1cf04a7e6e47", "name": "p1rdt75lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "edb1309f-17be-473e-9536-b73605ba9cc7"}}}}, {"uuid": "89e8b4bd-54f6-445d-98bc-cbfabb734b35", "name": "", "x": 38.70198343088721, "y": -122.38614802224237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "345b5c48-cd35-418e-bc08-50c06f5dff09", "name": "p1rlv151", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "89e8b4bd-54f6-445d-98bc-cbfabb734b35"}}}}, {"uuid": "fe33c8c8-9a84-4be4-9d3a-b3f0264e9519", "name": "", "x": 38.701353959316926, "y": -122.37840985382832, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4ecf2223-f120-45b4-8aab-a36d60161aec", "name": "p1rdt76lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fe33c8c8-9a84-4be4-9d3a-b3f0264e9519"}}}}, {"uuid": "8c23f4f5-3dcd-403e-892a-0178fb27e88f", "name": "", "x": 38.70149204336824, "y": -122.37842413503941, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5ccdfbc7-d3a6-4f74-ad32-25ff11a2e3b7", "name": "p1rlv154", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8c23f4f5-3dcd-403e-892a-0178fb27e88f"}}}}, {"uuid": "aeb979fd-4489-43fd-97d9-b0b766b3b211", "name": "", "x": 38.70130360088785, "y": -122.37857526759122, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0bd295ef-2c38-4c6b-915a-73900e920b92", "name": "p1rdm163", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aeb979fd-4489-43fd-97d9-b0b766b3b211"}}}}, {"uuid": "71b04380-49f0-49d3-b901-8a86282d5917", "name": "", "x": 38.70119454861773, "y": -122.37840371014978, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ebbe09dd-7560-4eff-9e32-803f14b4ce7c", "name": "p1rlv153", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "71b04380-49f0-49d3-b901-8a86282d5917"}}}}, {"uuid": "ca1e267b-7f14-4898-83f6-e667edcf4f24", "name": "", "x": 38.702363895820405, "y": -122.37852761379413, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3fd9bf7-ecdd-4dcb-966a-f426d5f2ee81", "name": "p1rdt77lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ca1e267b-7f14-4898-83f6-e667edcf4f24"}}}}, {"uuid": "b239dd78-4f54-4445-a01c-6bb955e0e274", "name": "", "x": 38.70251884097236, "y": -122.37832324388756, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2452d5af-5aba-4d4b-8cd9-27a95fe6b34d", "name": "p1rlv155", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b239dd78-4f54-4445-a01c-6bb955e0e274"}}}}, {"uuid": "447d14e7-4cba-4661-a6d7-a03c610b24ec", "name": "", "x": 38.70156690402656, "y": -122.3772504726202, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e110db24-1653-41b5-8496-821dfff05769", "name": "p1rdm166", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "447d14e7-4cba-4661-a6d7-a03c610b24ec"}}}}, {"uuid": "b80bc469-eb08-4031-91e6-8f576656fd95", "name": "", "x": 38.70172886217702, "y": -122.37720306729005, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7f607e6b-9540-4845-9f0c-6c334eb0e807", "name": "p1rlv156", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b80bc469-eb08-4031-91e6-8f576656fd95"}}}}, {"uuid": "07ca0dfe-b006-46d0-b7d7-c4e4d17b93f4", "name": "", "x": 38.7015268414049, "y": -122.37702834108411, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6f0255b7-5369-40eb-8814-959b0d4245b6", "name": "p1rdt78lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "07ca0dfe-b006-46d0-b7d7-c4e4d17b93f4"}}}}, {"uuid": "aa172697-4d3c-4c21-ad14-791eaaaae1de", "name": "", "x": 38.701501251821085, "y": -122.3767680365563, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c108a0c2-3093-4222-9547-5ac08f6d8a4a", "name": "p1rdm167", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aa172697-4d3c-4c21-ad14-791eaaaae1de"}}}}, {"uuid": "aa54beeb-e05e-40ae-b161-8212e8387d82", "name": "", "x": 38.701672466226256, "y": -122.3767665504658, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a0ae6c02-c29e-4bf9-b1d4-ecc7e37e7de2", "name": "p1rlv159", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aa54beeb-e05e-40ae-b161-8212e8387d82"}}}}, {"uuid": "fbaafc47-9f3c-4277-aaf2-71b0af1b7b7f", "name": "", "x": 38.701573552558834, "y": -122.37796740020737, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "624d03d5-ac53-4d58-ac86-62834fa13c61", "name": "p1rdt79lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fbaafc47-9f3c-4277-aaf2-71b0af1b7b7f"}}}}, {"uuid": "5d4081fd-db54-430c-9651-49ca8ccb19c8", "name": "", "x": 38.70167012893807, "y": -122.378020087898, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "61460072-bdc5-4a70-96fa-8ecfa71623f4", "name": "p1rlv164", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5d4081fd-db54-430c-9651-49ca8ccb19c8"}}}}, {"uuid": "5ddc2017-08f1-4c34-af08-946e29dacc50", "name": "", "x": 38.70151736520935, "y": -122.37810191210743, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "937989ee-4525-4394-b04f-37d77a2c910c", "name": "p1rdm168", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ddc2017-08f1-4c34-af08-946e29dacc50"}}}}, {"uuid": "6e2f44f8-35c0-4ebe-be9e-289c5eb1dec3", "name": "", "x": 38.701243377810904, "y": -122.37795080752997, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4355a473-4643-4f72-afe8-80ce773ca8e8", "name": "p1rlv157", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6e2f44f8-35c0-4ebe-be9e-289c5eb1dec3"}}}}, {"uuid": "f766d922-c367-4ee9-9fb6-96a42381bf45", "name": "", "x": 38.70217305711017, "y": -122.38794268559874, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3ce05c72-facf-447f-ba14-cc2ef64579a8", "name": "p1rdt80lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f766d922-c367-4ee9-9fb6-96a42381bf45"}}}}, {"uuid": "6a03f728-1d34-40e8-9d44-4347597d087c", "name": "", "x": 38.70228005247363, "y": -122.38772102191264, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b1cd7284-17fb-4382-a29d-dd8c5bfd7541", "name": "p1rlv158", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a03f728-1d34-40e8-9d44-4347597d087c"}}}}, {"uuid": "35d2c24a-971e-45b2-a2e3-22eccd876c81", "name": "", "x": 38.7016172629152, "y": -122.37771401826583, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1b610625-09e3-4b72-a8fe-b0c36f5e137c", "name": "p1rdt81lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "35d2c24a-971e-45b2-a2e3-22eccd876c81"}}}}, {"uuid": "f378ac7d-d200-4e41-a406-ab7054564695", "name": "", "x": 38.701704338541916, "y": -122.37767478667475, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fd2fae5a-e5dd-4ad4-8acc-422de00ae83e", "name": "p1rlv160", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f378ac7d-d200-4e41-a406-ab7054564695"}}}}, {"uuid": "85bcfea0-d3da-47ac-b484-16d7e9deb5ef", "name": "", "x": 38.7014372533443, "y": -122.37659609024615, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e2dad274-0d92-42fa-bf1e-a22af034211f", "name": "p1rdm172", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "85bcfea0-d3da-47ac-b484-16d7e9deb5ef"}}}}, {"uuid": "67b2edbf-fb9a-4042-9878-0abb256c07b4", "name": "", "x": 38.701284735816664, "y": -122.3767239154521, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4842819e-3f17-47da-a8bf-c3402c3c00b7", "name": "p1rlv161", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "67b2edbf-fb9a-4042-9878-0abb256c07b4"}}}}, {"uuid": "8faa352b-237f-48a0-9eeb-1ca7041e4a54", "name": "", "x": 38.701286056772844, "y": -122.37644037803527, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9872669f-fd85-458a-8951-ec12965fb42b", "name": "p1rdt82lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8faa352b-237f-48a0-9eeb-1ca7041e4a54"}}}}, {"uuid": "e2c58a52-518f-4c8c-9b38-b8662ad5ade7", "name": "", "x": 38.70116550444912, "y": -122.3763339478172, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "44bdfec0-2d44-442d-b562-ac786c61a76a", "name": "p1rdm173", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e2c58a52-518f-4c8c-9b38-b8662ad5ade7"}}}}, {"uuid": "c8e5702d-def0-482b-8f6a-0620e7bbbeff", "name": "", "x": 38.70118248419553, "y": -122.37613829900104, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b7538477-32ab-4db6-872d-83be7ec89fd9", "name": "p1rlv830", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c8e5702d-def0-482b-8f6a-0620e7bbbeff"}}}}, {"uuid": "3adcb55d-9b1a-46b3-b905-26ad4c6bff2d", "name": "", "x": 38.70185461418825, "y": -122.38682011107082, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8dac1e07-5eb6-4945-a3d9-95b77310358d", "name": "p1rdt83lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3adcb55d-9b1a-46b3-b905-26ad4c6bff2d"}}}}, {"uuid": "4a73fce2-8e99-4a9f-bc75-215c102dbda8", "name": "", "x": 38.702004410202626, "y": -122.38671135342908, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "471bad88-4514-4b02-aa1a-1d2aaa15557f", "name": "p1rlv163", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4a73fce2-8e99-4a9f-bc75-215c102dbda8"}}}}, {"uuid": "fbb96684-d951-42a4-a1f6-ce4c0c253377", "name": "", "x": 38.70161136737774, "y": -122.38394317395175, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d9de64e4-b140-4526-af3c-1f7ceaa687bf", "name": "p1rdm175", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fbb96684-d951-42a4-a1f6-ce4c0c253377"}}}}, {"uuid": "5a097ffc-12e8-463a-bd24-dd8185e42490", "name": "", "x": 38.701999398350054, "y": -122.38404334662313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9e7880c9-0932-4395-abf9-2274e400f280", "name": "p1rlv165", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5a097ffc-12e8-463a-bd24-dd8185e42490"}}}}, {"uuid": "61710186-ca37-4767-9c87-d70a0b168e59", "name": "", "x": 38.70158970365277, "y": -122.38378988145172, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bdb8aaf1-0e21-42e0-a72d-666646561235", "name": "p1rdt84lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "61710186-ca37-4767-9c87-d70a0b168e59"}}}}, {"uuid": "5d8a0ae0-27e3-4461-b370-f4c1e51c40dd", "name": "", "x": 38.701645776351214, "y": -122.38363237450628, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8a6bf0b9-809d-48fb-b8bd-375df052b6cc", "name": "p1rdm176", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5d8a0ae0-27e3-4461-b370-f4c1e51c40dd"}}}}, {"uuid": "209596cf-c99f-4561-a520-381ebd08802a", "name": "", "x": 38.70187142242643, "y": -122.3836994386808, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "21d333f7-7426-4fa6-8ab2-c6118055ece1", "name": "p1rlv166", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "209596cf-c99f-4561-a520-381ebd08802a"}}}}, {"uuid": "a079cab2-18b3-4986-9bd6-e862df6a3992", "name": "", "x": 38.70159534277448, "y": -122.37751697598218, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "40f4034e-c735-419b-80cd-d729d75f4692", "name": "p1rdt85lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a079cab2-18b3-4986-9bd6-e862df6a3992"}}}}, {"uuid": "d5be180e-e603-44df-91b2-15bf09529aaa", "name": "", "x": 38.70142358074945, "y": -122.3774127173029, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "470fe3ed-5b24-438a-ba6d-cdd9f774e5ad", "name": "p1rlv168", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d5be180e-e603-44df-91b2-15bf09529aaa"}}}}, {"uuid": "9ad1b5f7-6de7-45a6-82fa-a019f2a2d2dd", "name": "", "x": 38.69187926915615, "y": -122.40371977394915, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29", "name": "p1rdt89lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9ad1b5f7-6de7-45a6-82fa-a019f2a2d2dd"}}}}, {"uuid": "2dcf3d7d-5bad-4a2a-89df-cc749726edb1", "name": "", "x": 38.69174128032129, "y": -122.40438031441046, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1186295-59ff-48a8-b31d-0f7cd40df1ab", "name": "p1rlv174", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2dcf3d7d-5bad-4a2a-89df-cc749726edb1"}}}}, {"uuid": "b8b95dc9-b571-48bb-b6a5-505568391f8f", "name": "", "x": 38.69209810103375, "y": -122.40366444006949, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "905e9287-bdb6-44e0-b0af-f59ab4ad4d8e", "name": "p1rlv175", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b8b95dc9-b571-48bb-b6a5-505568391f8f"}}}}, {"uuid": "fd83f614-e9b0-4c57-8f6b-38f4f1283fb9", "name": "", "x": 38.69217885130816, "y": -122.4035947777604, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "931c8cee-89fe-447d-8788-af1e5f9f8775", "name": "p1rlv176", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fd83f614-e9b0-4c57-8f6b-38f4f1283fb9"}}}}, {"uuid": "d368bf8f-c6cb-4bf9-ac2a-89d02da7ed90", "name": "", "x": 38.6915327307124, "y": -122.40412907570833, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "090d6084-5cc6-473d-99c0-a6309571d633", "name": "p1rlv177", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d368bf8f-c6cb-4bf9-ac2a-89d02da7ed90"}}}}, {"uuid": "f010dad3-54f5-452e-a9dc-a82317b93f0f", "name": "", "x": 38.69192571259695, "y": -122.40343589909303, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a9debf70-62f4-4870-ad8b-bffc4bc4ad3f", "name": "p1rlv178", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f010dad3-54f5-452e-a9dc-a82317b93f0f"}}}}, {"uuid": "3b0576c8-db7c-411b-9c1c-bfa9f59cbb2b", "name": "", "x": 38.69194238589858, "y": -122.40317129254535, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fb03260b-d7d7-4779-ab2c-37c9a1e34d66", "name": "p1rlv179", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3b0576c8-db7c-411b-9c1c-bfa9f59cbb2b"}}}}, {"uuid": "1d052612-64a8-4667-9de7-cadc1ee125d3", "name": "", "x": 38.690562886551874, "y": -122.39178515337943, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d156fdde-5620-4a6f-b8c1-a3ab986fcc88", "name": "p1rdt150lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d052612-64a8-4667-9de7-cadc1ee125d3"}}}}, {"uuid": "30a89bc3-9ed4-40c7-9ecb-6c588b8c5880", "name": "", "x": 38.69053687920906, "y": -122.3917425303033, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8d3a86df-2ac5-4959-b857-562795ce84ba", "name": "p1rlv285", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "30a89bc3-9ed4-40c7-9ecb-6c588b8c5880"}}}}, {"uuid": "53d8affc-2792-4637-a447-6a4e58c78313", "name": "", "x": 38.66809150084286, "y": -122.48424417400362, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d64d858-a9f7-430f-890e-a456f8913c30", "name": "p1rdt177lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "53d8affc-2792-4637-a447-6a4e58c78313"}}}}, {"uuid": "7607cd8e-f257-4a6d-b55c-9a898d29baf6", "name": "", "x": 38.66811702312487, "y": -122.4842010892547, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "57b88281-b728-4779-82b1-4cc9eb4b41b1", "name": "p1rlv337", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7607cd8e-f257-4a6d-b55c-9a898d29baf6"}}}}, {"uuid": "de0c745d-5ced-43d0-9095-ed76c1548f39", "name": "", "x": 38.681876674272594, "y": -122.49390622766961, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b3314fa8-a838-4028-abb5-043425fd0785", "name": "p1rdt178lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "de0c745d-5ced-43d0-9095-ed76c1548f39"}}}}, {"uuid": "81b033cd-6820-4e9d-9d4a-fe4406f73e5e", "name": "", "x": 38.68190220002097, "y": -122.49386313799357, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e6b2aba6-a289-4a50-a131-2064047d1341", "name": "p1rlv338", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "81b033cd-6820-4e9d-9d4a-fe4406f73e5e"}}}}, {"uuid": "a7b6930a-f33e-4110-8b61-e7e73d1f1ddc", "name": "", "x": 38.66898414531813, "y": -122.45869594003535, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c3e633bc-311e-4698-a413-9c6cf09c42a8", "name": "p1rdt180lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a7b6930a-f33e-4110-8b61-e7e73d1f1ddc"}}}}, {"uuid": "6b1f1532-b5d7-4977-bb8a-eeb24a23de79", "name": "", "x": 38.66899849994981, "y": -122.45874675513116, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bb4797d6-b46e-4058-8985-d9f4b660f0a7", "name": "p1rlv340", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6b1f1532-b5d7-4977-bb8a-eeb24a23de79"}}}}, {"uuid": "ea35ba17-1f44-4509-80ca-f02601f3838a", "name": "", "x": 38.75302665769167, "y": -122.36662619401973, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "05401825-91f8-41f8-9204-ab5806458594", "name": "p1rdt181lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea35ba17-1f44-4509-80ca-f02601f3838a"}}}}, {"uuid": "53a2fe42-5fec-4c3f-bb86-47337d445449", "name": "", "x": 38.75299240671526, "y": -122.36643483348682, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "54f0ea2c-3849-4ff0-ad8c-e3f65515d178", "name": "p1rlv341", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "53a2fe42-5fec-4c3f-bb86-47337d445449"}}}}, {"uuid": "d7210e3a-8ceb-4042-887e-2baf51dd5726", "name": "", "x": 38.75309371224946, "y": -122.36683673194118, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "13754fdb-4039-49fb-b584-8437191dfb2b", "name": "p1rlv342", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d7210e3a-8ceb-4042-887e-2baf51dd5726"}}}}, {"uuid": "953e5e3a-8f85-4748-8249-0703ee775dc5", "name": "", "x": 38.67877405858776, "y": -122.47520020508532, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "db407ddd-fb81-4767-99e1-9aeab12fc770", "name": "p1rdt182lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "953e5e3a-8f85-4748-8249-0703ee775dc5"}}}}, {"uuid": "2f6bbaf5-24aa-40e8-b566-845c59a445a2", "name": "", "x": 38.6787480814273, "y": -122.47515755839895, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0197ef22-9f8f-48a9-84de-663a7ce22773", "name": "p1rlv343", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2f6bbaf5-24aa-40e8-b566-845c59a445a2"}}}}, {"uuid": "35e5b909-f634-4a8b-b66b-4e8bede0808f", "name": "", "x": 38.68506507552232, "y": -122.35588924552482, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4724ea16-dc31-48f8-98b8-b9a223e9a4bb", "name": "p1rdt209lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "35e5b909-f634-4a8b-b66b-4e8bede0808f"}}}}, {"uuid": "1ba1a288-120a-4dbf-bfb8-42f4858ad738", "name": "", "x": 38.68512263068088, "y": -122.3560076800405, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7e1ea241-5329-4db5-996a-df09a9c25687", "name": "p1rlv377", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1ba1a288-120a-4dbf-bfb8-42f4858ad738"}}}}, {"uuid": "4df59d4a-6893-4f1b-b48e-0db3cf09f7af", "name": "", "x": 38.68504927407323, "y": -122.35577838786406, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "50225dcf-40bc-44b5-9dec-072ac5b2334e", "name": "p1rlv379", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4df59d4a-6893-4f1b-b48e-0db3cf09f7af"}}}}, {"uuid": "1885af1b-3bcd-4472-8d94-a5c3f52eb2c6", "name": "", "x": 38.684623418522186, "y": -122.35792952524736, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "05f6a3bf-d465-4f16-8205-616d1f4dd465", "name": "p1rdt210lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1885af1b-3bcd-4472-8d94-a5c3f52eb2c6"}}}}, {"uuid": "61baa391-c9f5-4078-ac02-6dd3b54a83b1", "name": "", "x": 38.684597398947716, "y": -122.35788691809313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d3ff63a0-bf3f-43b0-807c-935467b4fe46", "name": "p1rlv378", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "61baa391-c9f5-4078-ac02-6dd3b54a83b1"}}}}, {"uuid": "10baed55-38a3-44cd-93db-649b00e85837", "name": "", "x": 38.68355474726837, "y": -122.35674337268465, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1d5af6ce-9a4c-414a-bbd8-15d82f50cb57", "name": "p1rdt211lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10baed55-38a3-44cd-93db-649b00e85837"}}}}, {"uuid": "08ef91ea-1f5d-4f98-98c3-eb8f6fa34493", "name": "", "x": 38.68358022206023, "y": -122.35670023394748, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0ee07ef9-b7b0-4457-be1c-78e754dbcfc7", "name": "p1rlv380", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "08ef91ea-1f5d-4f98-98c3-eb8f6fa34493"}}}}, {"uuid": "16164883-d887-47fc-aabd-993c8668dba9", "name": "", "x": 38.70346378054364, "y": -122.37754850885149, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "591461d4-20da-4165-a210-4dbaedd81016", "name": "p1rdt233lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "16164883-d887-47fc-aabd-993c8668dba9"}}}}, {"uuid": "646ac96d-cdc9-49c3-a0f1-3ae8e77da6b9", "name": "", "x": 38.703632263710084, "y": -122.37756607257536, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b54aae8-5a94-4e04-882f-748e1c5f1390", "name": "p1rlv415", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "646ac96d-cdc9-49c3-a0f1-3ae8e77da6b9"}}}}, {"uuid": "6c429ce0-0fef-418f-9d71-d67238478aa4", "name": "", "x": 38.70329902987842, "y": -122.37760346268222, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "99abc7dc-8e15-420f-9bc9-0e6229d4dab3", "name": "p1rlv416", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c429ce0-0fef-418f-9d71-d67238478aa4"}}}}, {"uuid": "9497beca-f842-4ee6-a8e5-508ab4b0b459", "name": "", "x": 38.70344498505631, "y": -122.37793571026356, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "019c88af-413c-4331-84f7-923a1df0a303", "name": "p1rdm434", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9497beca-f842-4ee6-a8e5-508ab4b0b459"}}}}, {"uuid": "0262bf06-9770-4733-99e9-cf98f80a689b", "name": "", "x": 38.703688840272775, "y": -122.37803710181561, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6b33ed36-116b-4741-9374-6927bd537427", "name": "p1rlv412", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0262bf06-9770-4733-99e9-cf98f80a689b"}}}}, {"uuid": "32ce07e1-cf47-4abf-b3bf-24f51f6cfdb1", "name": "", "x": 38.703449772341166, "y": -122.3771421382582, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e3b3eb51-c011-4f2c-8a10-c43c9c86217b", "name": "p1rdm437", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "32ce07e1-cf47-4abf-b3bf-24f51f6cfdb1"}}}}, {"uuid": "294366aa-f7eb-4e04-8d91-2eceb5798884", "name": "", "x": 38.70363888674939, "y": -122.37711749672587, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e7935b9c-b631-432c-a322-9beea73f1fc4", "name": "p1rlv419", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "294366aa-f7eb-4e04-8d91-2eceb5798884"}}}}, {"uuid": "6bcfb4f6-2e39-4863-80fb-e741b4350228", "name": "", "x": 38.70342206460632, "y": -122.37701587380883, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1a713d96-e13f-447e-ab9f-012af3e26afe", "name": "p1rdm438", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6bcfb4f6-2e39-4863-80fb-e741b4350228"}}}}, {"uuid": "d9702311-ea42-4ddf-ae4e-121430adc593", "name": "", "x": 38.703538904912854, "y": -122.37695735772205, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be4d7ed8-5ddd-4127-87ab-eb3f48a580c2", "name": "p1rlv420", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d9702311-ea42-4ddf-ae4e-121430adc593"}}}}, {"uuid": "ad647b8c-5c1a-41de-9194-421c09929204", "name": "", "x": 38.70315939892254, "y": -122.38015776111975, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "adb2d039-e162-43f7-8498-1374581a75fc", "name": "p1rdm439", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ad647b8c-5c1a-41de-9194-421c09929204"}}}}, {"uuid": "760681c9-084f-4e36-a61d-5f3745e7cd14", "name": "", "x": 38.70329481206863, "y": -122.38020259377379, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8408ac87-a086-46bc-9d88-cca79e17dd62", "name": "p1rlv413", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "760681c9-084f-4e36-a61d-5f3745e7cd14"}}}}, {"uuid": "d0c778bc-b90c-47b5-8172-39b840e24616", "name": "", "x": 38.70311258602368, "y": -122.38036119573296, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e480f304-b192-4107-91e1-131d481657b2", "name": "p1rdt234lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d0c778bc-b90c-47b5-8172-39b840e24616"}}}}, {"uuid": "dcdc577e-1e4f-42be-b252-c5958b06d753", "name": "", "x": 38.7029185925103, "y": -122.38063135468911, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "84570b2e-efeb-477e-be1c-43b9d2922fda", "name": "p1rdm440", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dcdc577e-1e4f-42be-b252-c5958b06d753"}}}}, {"uuid": "3fe19806-a4a8-4e42-a1c2-255007fc068e", "name": "", "x": 38.7029199228882, "y": -122.38034781076358, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "49dbdd44-a36a-46b5-aef8-558ef7693315", "name": "p1rlv417", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3fe19806-a4a8-4e42-a1c2-255007fc068e"}}}}, {"uuid": "f7a94d2a-3acd-4984-af0d-c281cf5c686d", "name": "", "x": 38.702857286057856, "y": -122.38150193355499, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d8a6708a-d098-4e02-aac6-4aba7fdc71a5", "name": "p1rdt235lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f7a94d2a-3acd-4984-af0d-c281cf5c686d"}}}}, {"uuid": "25aebc37-4fc6-4413-8a7a-b0c4254ee4f0", "name": "", "x": 38.70300468515236, "y": -122.38157364260027, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "12dcb168-1bfe-448b-8d9a-f5cb4c61aafe", "name": "p1rlv421", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "25aebc37-4fc6-4413-8a7a-b0c4254ee4f0"}}}}, {"uuid": "deb1598d-1ec1-41d1-8f30-df41804e8290", "name": "", "x": 38.70336335384591, "y": -122.37836945726418, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7dd709e3-c5ec-4a01-8297-11f4d1261c3a", "name": "p1rdt236lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "deb1598d-1ec1-41d1-8f30-df41804e8290"}}}}, {"uuid": "4713b3a2-a889-4ee0-b304-c3718091deae", "name": "", "x": 38.70357389491814, "y": -122.3784521142025, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aa7bb51b-8ba8-4a05-872a-7f5ce084fe88", "name": "p1rlv422", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4713b3a2-a889-4ee0-b304-c3718091deae"}}}}, {"uuid": "299ac3a7-1294-41c6-bdfe-f81fcbac0440", "name": "", "x": 38.70326683877779, "y": -122.37832826777388, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6c1e9680-f7de-497c-953a-54f4db2899e2", "name": "p1rlv423", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "299ac3a7-1294-41c6-bdfe-f81fcbac0440"}}}}, {"uuid": "69492088-1302-4501-8eb1-50d1ab439d19", "name": "", "x": 38.69944370500361, "y": -122.41580872476209, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b72726f3-250c-4d98-86bc-5120137bd0f1", "name": "p1rdt237lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "69492088-1302-4501-8eb1-50d1ab439d19"}}}}, {"uuid": "98d78dd8-503b-4dca-8dd9-5465a16c50ee", "name": "", "x": 38.69954841432615, "y": -122.41568889821919, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e1a91c8c-aabd-4fad-8306-908f186a5744", "name": "p1rlv424", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "98d78dd8-503b-4dca-8dd9-5465a16c50ee"}}}}, {"uuid": "85c0e239-6490-4ec7-87dd-d66b31f76a42", "name": "", "x": 38.69927637037365, "y": -122.4159171313363, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "753035df-8705-48eb-92b3-c4bef603b66b", "name": "p1rlv449", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "85c0e239-6490-4ec7-87dd-d66b31f76a42"}}}}, {"uuid": "9558861f-5a1b-4bd9-ba31-559c8aa3081b", "name": "", "x": 38.70680842002751, "y": -122.42486556791981, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "42dff28c-89e7-4b56-bf23-3dcdd3ca216f", "name": "p1rdt251lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9558861f-5a1b-4bd9-ba31-559c8aa3081b"}}}}, {"uuid": "e1935b1d-1c47-4379-ae94-01784a6da9a1", "name": "", "x": 38.70631853264042, "y": -122.42524857112629, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2f771660-4dad-43df-b38b-7da5f6180a25", "name": "p1rlv439", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e1935b1d-1c47-4379-ae94-01784a6da9a1"}}}}, {"uuid": "dee0ea3a-c26d-4a97-b33b-933c3b68df0b", "name": "", "x": 38.70720720644569, "y": -122.42453989136035, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0d665758-71e1-4478-b39d-671f78f623e5", "name": "p1rlv445", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dee0ea3a-c26d-4a97-b33b-933c3b68df0b"}}}}, {"uuid": "ce5d7daa-a960-4160-80bd-5a74b7ce65ff", "name": "", "x": 38.70744608256419, "y": -122.42546956600445, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "acce3105-f519-491c-921a-df1294795742", "name": "p1rlv446", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ce5d7daa-a960-4160-80bd-5a74b7ce65ff"}}}}, {"uuid": "29f44b7f-784a-4c81-83d9-75ac5e82c9e1", "name": "", "x": 38.70608276722945, "y": -122.42495143556884, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "042873fa-10df-4de0-a040-ac429b8bf7d9", "name": "p1rlv447", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "29f44b7f-784a-4c81-83d9-75ac5e82c9e1"}}}}, {"uuid": "5305ea3c-176d-4627-80b2-70f68e3b3249", "name": "", "x": 38.70711624377896, "y": -122.42436810473787, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4bb83d65-630d-4f1d-8e3d-8937a5a05524", "name": "p1rlv448", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5305ea3c-176d-4627-80b2-70f68e3b3249"}}}}, {"uuid": "8c2a657b-ca27-44ca-9109-2bc7768188c8", "name": "", "x": 38.78777229039905, "y": -122.347029423475, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "704fece3-3b83-4c0b-bcd1-d463b3cdaf6b", "name": "p1rdt253lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8c2a657b-ca27-44ca-9109-2bc7768188c8"}}}}, {"uuid": "793f6ac1-bd76-48ee-b6b1-d7f4fea5c5fb", "name": "", "x": 38.78740834836766, "y": -122.34691362308135, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0a778b00-482c-4b81-8213-f17202a105fa", "name": "p1rlv441", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "793f6ac1-bd76-48ee-b6b1-d7f4fea5c5fb"}}}}, {"uuid": "c229e0d5-b101-4f6e-b560-2f2e9acc9bab", "name": "", "x": 38.78809447859801, "y": -122.3471376433436, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "30f29674-3083-4da2-95e2-a1f11a7eb7f8", "name": "p1rlv444", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c229e0d5-b101-4f6e-b560-2f2e9acc9bab"}}}}, {"uuid": "41ca8386-0452-4bf9-be70-2fadb63707ca", "name": "", "x": 38.706805740104386, "y": -122.42594225497479, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "655d8f44-aa2f-4548-a1ca-83fcce9fa7aa", "name": "p1rdt254lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "41ca8386-0452-4bf9-be70-2fadb63707ca"}}}}, {"uuid": "3c269399-d74c-4d59-a8d2-dafb03efc520", "name": "", "x": 38.70689780217361, "y": -122.42576147929557, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6cd667a9-c0ef-49ce-b6ee-7e474d9ae761", "name": "p1rlv442", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3c269399-d74c-4d59-a8d2-dafb03efc520"}}}}, {"uuid": "e57dd29b-9cd7-424b-a501-9ee3096a6870", "name": "", "x": 38.706755483647314, "y": -122.4261421504902, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c2100c17-c0e6-47e9-87f8-72016b22dd4b", "name": "p1rlv443", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e57dd29b-9cd7-424b-a501-9ee3096a6870"}}}}, {"uuid": "538a31a7-d921-47e6-9d70-ef1da95cfcb4", "name": "", "x": 38.68872418378523, "y": -122.3484131511325, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e4c28500-44f7-47c6-b8a8-d1e3468494e3", "name": "p1rdt257lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "538a31a7-d921-47e6-9d70-ef1da95cfcb4"}}}}, {"uuid": "7d61257b-f6a2-48da-9a96-61fb9f4ca7c8", "name": "", "x": 38.68876626401415, "y": -122.34840879300008, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bb46f1ae-0cdb-45d1-b389-639cdf345f8e", "name": "p1rlv452", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7d61257b-f6a2-48da-9a96-61fb9f4ca7c8"}}}}, {"uuid": "80be5501-4a72-4a0b-a037-72d42ecb1ebd", "name": "", "x": 38.69599975733859, "y": -122.39252773638533, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ad9ffaef-f21b-43da-9f67-3a8271edb6bd", "name": "p1rdt258lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "80be5501-4a72-4a0b-a037-72d42ecb1ebd"}}}}, {"uuid": "98e49797-c26c-470d-af4f-29283772b7f7", "name": "", "x": 38.695944209864116, "y": -122.39278871278485, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f6a8a3c7-5165-48b7-8233-30d3af045442", "name": "p1rlv453", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "98e49797-c26c-470d-af4f-29283772b7f7"}}}}, {"uuid": "f90c9866-5b26-4071-a4fc-b0a7d6c52f2d", "name": "", "x": 38.69600232943997, "y": -122.39183378308958, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "85f0d94e-c096-4d53-ae05-f0dc59f73d02", "name": "p1rlv456", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f90c9866-5b26-4071-a4fc-b0a7d6c52f2d"}}}}, {"uuid": "de4f8fed-9482-452a-90c9-5e7caec23923", "name": "", "x": 38.69599911358809, "y": -122.39294923817128, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "76b212f9-2e27-4064-a2c5-079786afb1d1", "name": "p1rlv460", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "de4f8fed-9482-452a-90c9-5e7caec23923"}}}}, {"uuid": "54918463-a6a7-4a05-bf52-c9011253cbfc", "name": "", "x": 38.68471814126827, "y": -122.36995372008337, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c6a0feb3-78c1-4d69-8d18-2a8c3abdcf54", "name": "p1rdt259lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "54918463-a6a7-4a05-bf52-c9011253cbfc"}}}}, {"uuid": "661f61fe-a47e-42bd-9f59-20f5526dc5b4", "name": "", "x": 38.684738584166, "y": -122.36987703423111, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3493b0ed-43a2-4602-a7ad-a817331c9d8e", "name": "p1rlv454", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "661f61fe-a47e-42bd-9f59-20f5526dc5b4"}}}}, {"uuid": "9a532ae9-3d3d-4204-b6db-339efb98c7a9", "name": "", "x": 38.68473945129645, "y": -122.37003799082656, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "552153cc-f5be-42ee-9985-9361c2e7e2a1", "name": "p1rlv455", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9a532ae9-3d3d-4204-b6db-339efb98c7a9"}}}}, {"uuid": "02d1b4b0-73de-4ac2-9167-0f91c0a87843", "name": "", "x": 38.69417505217448, "y": -122.39691277672273, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d8d796d8-6750-4ca5-ae07-1b07331ce6ee", "name": "p1rdt260lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "02d1b4b0-73de-4ac2-9167-0f91c0a87843"}}}}, {"uuid": "c2a504be-9d17-43d9-a528-ac7860584549", "name": "", "x": 38.69444988952913, "y": -122.39658452058625, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ec66e302-748d-4300-ba65-719de0a906bb", "name": "p1rlv458", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c2a504be-9d17-43d9-a528-ac7860584549"}}}}, {"uuid": "3faab6eb-e94a-4a73-8298-c56a3209c291", "name": "", "x": 38.69489061384813, "y": -122.39641983065454, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "76dd0f1b-4109-4707-a547-f0ab1b6e148f", "name": "p1rlv461", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3faab6eb-e94a-4a73-8298-c56a3209c291"}}}}, {"uuid": "e28b20ea-136d-493a-b93f-1d8c8d2e0275", "name": "", "x": 38.69609340912066, "y": -122.39266578758262, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fe4ec5b6-61fb-4b66-9e43-19d81af88966", "name": "p1rdt261lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e28b20ea-136d-493a-b93f-1d8c8d2e0275"}}}}, {"uuid": "32b9738c-437a-49e1-bcf9-ba63fbef1757", "name": "", "x": 38.69613569697208, "y": -122.39266409008623, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4c112196-bcbc-41bc-99a9-f3657c335c7a", "name": "p1rlv459", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "32b9738c-437a-49e1-bcf9-ba63fbef1757"}}}}, {"uuid": "fc0b9de9-847e-4f4c-9650-639faab16240", "name": "", "x": 38.69746455104433, "y": -122.39109295618859, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "30952601-1479-4770-9b77-9fe3465310b7", "name": "p1rdt262lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fc0b9de9-847e-4f4c-9650-639faab16240"}}}}, {"uuid": "4bce323d-cade-48f6-bd80-19de38309d9c", "name": "", "x": 38.697566588571334, "y": -122.39110756675504, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9176da24-7eb5-4b0b-99dd-886c3f974798", "name": "p1rlv462", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4bce323d-cade-48f6-bd80-19de38309d9c"}}}}, {"uuid": "614237e9-0299-4752-b3bd-ac572efbc93f", "name": "", "x": 38.69741333633857, "y": -122.39109736665547, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "895d0235-3ee6-4f06-9978-9d615d721ebd", "name": "p1rlv464", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "614237e9-0299-4752-b3bd-ac572efbc93f"}}}}, {"uuid": "85ef6f5a-7f9c-417e-a030-2cddbc51d968", "name": "", "x": 38.69796207835795, "y": -122.39189498505252, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2c7501f4-0394-4766-a3c5-b17fda7f3817", "name": "p1rdt263lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "85ef6f5a-7f9c-417e-a030-2cddbc51d968"}}}}, {"uuid": "020235d3-cf73-4472-bd30-ddd25a084052", "name": "", "x": 38.69793607105191, "y": -122.39185235758016, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ff9d9cca-1878-478d-a190-b58c9098f13e", "name": "p1rlv463", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "020235d3-cf73-4472-bd30-ddd25a084052"}}}}, {"uuid": "a47e9ee1-03b2-4ff9-935d-f8a781ece2cd", "name": "", "x": 38.7505574694735, "y": -122.41550076869619, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d33a03d6-fddc-4e47-8018-cd7d290b30b0", "name": "p1rdt270lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a47e9ee1-03b2-4ff9-935d-f8a781ece2cd"}}}}, {"uuid": "dbb5ba0e-ba1e-4371-bcd8-6e1f788e6252", "name": "", "x": 38.75057184305653, "y": -122.41555163249289, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2e589527-d388-4364-87d2-2f4af1a14509", "name": "p1rlv474", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dbb5ba0e-ba1e-4371-bcd8-6e1f788e6252"}}}}, {"uuid": "18d6fe25-b7b6-445a-ae4b-e251280306d0", "name": "", "x": 38.77190208512443, "y": -122.36444610004378, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6715c6a-6869-412a-8e59-e5c2eb03c56b", "name": "p1rdt275lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "18d6fe25-b7b6-445a-ae4b-e251280306d0"}}}}, {"uuid": "f5d52a4c-e524-4515-8bd6-5a25557f9ba1", "name": "", "x": 38.77188833047837, "y": -122.36449725722824, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cb55ec0b-b6f7-48a7-8dae-dda95fc34499", "name": "p1rlv480", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5d52a4c-e524-4515-8bd6-5a25557f9ba1"}}}}, {"uuid": "e49c6293-1f6d-43c7-9f99-3bad9fb91f2e", "name": "", "x": 38.6981164551154, "y": -122.40319272296294, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b478b4f8-8d5e-47b0-a56a-8b991dc8d944", "name": "p1rdt276lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e49c6293-1f6d-43c7-9f99-3bad9fb91f2e"}}}}, {"uuid": "c92307a0-d75e-4ba8-8c7a-0fc694691602", "name": "", "x": 38.69831357847344, "y": -122.40315284432228, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8d9e77ad-42c6-4413-96e6-debfed3c442a", "name": "p1rlv481", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c92307a0-d75e-4ba8-8c7a-0fc694691602"}}}}, {"uuid": "78102e48-a7be-4d96-894e-01561d3adb23", "name": "", "x": 38.697080868964996, "y": -122.39900074624246, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "24486e15-ff1e-45b3-aa02-703263f04844", "name": "p1rdt277lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "78102e48-a7be-4d96-894e-01561d3adb23"}}}}, {"uuid": "4daf40d1-d481-436a-ab75-fc0ab9938839", "name": "", "x": 38.696472678672315, "y": -122.39914337613104, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8d4b708f-cc15-4ee3-87e0-4d26fec02f1e", "name": "p1rlv482", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4daf40d1-d481-436a-ab75-fc0ab9938839"}}}}, {"uuid": "7a0f4694-1f59-45db-ac24-c397b84f74bf", "name": "", "x": 38.682836254431685, "y": -122.35413994526482, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a8af5824-d5d7-4cba-98b7-d72993909f22", "name": "p1rdt278lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7a0f4694-1f59-45db-ac24-c397b84f74bf"}}}}, {"uuid": "ae9edf40-7cf8-4a90-b1fb-e195a11a717e", "name": "", "x": 38.682850654364266, "y": -122.35419074861349, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d059a618-6f09-404b-b1a0-0e7aa0c55c45", "name": "p1rlv483", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ae9edf40-7cf8-4a90-b1fb-e195a11a717e"}}}}, {"uuid": "5e812994-8ece-4fc5-8b76-348599a6e2ce", "name": "", "x": 38.696321369018115, "y": -122.40303140946239, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2d6856ee-d113-45ec-99e0-8a915a89a56c", "name": "p1rdm508", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5e812994-8ece-4fc5-8b76-348599a6e2ce"}}}}, {"uuid": "b52b0521-4625-42cf-a321-7a6ef164fc92", "name": "", "x": 38.6966231134774, "y": -122.40212045173747, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fde62b60-c5f6-44d6-b2f2-211c21b02033", "name": "p1rlv484", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b52b0521-4625-42cf-a321-7a6ef164fc92"}}}}, {"uuid": "ef878753-5b7b-4b1e-adac-6f6766e7a2bf", "name": "", "x": 38.69619520198978, "y": -122.40301175619707, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4bf679fe-712f-4db6-9df9-debb29b7ee73", "name": "p1rdt279lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef878753-5b7b-4b1e-adac-6f6766e7a2bf"}}}}, {"uuid": "38f0df30-9996-4460-baaf-8cf45c0bdea2", "name": "", "x": 38.69610445115518, "y": -122.40290672048755, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9c3bf9bd-d12a-47d7-b2e2-3f31f3a0419b", "name": "p1rdm509", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "38f0df30-9996-4460-baaf-8cf45c0bdea2"}}}}, {"uuid": "6a1f742e-0281-41f8-a274-ca742d98c351", "name": "", "x": 38.69640566539714, "y": -122.40189227549035, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f8d2c379-7e19-46c4-8c6e-533fa9db7764", "name": "p1rlv485", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a1f742e-0281-41f8-a274-ca742d98c351"}}}}, {"uuid": "958a623e-a829-4d3b-b310-b6a20945b961", "name": "", "x": 38.762845986496735, "y": -122.35672935763573, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e4eafd2-0f68-4e2a-a62c-89cb877004d4", "name": "p1rdt280lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "958a623e-a829-4d3b-b310-b6a20945b961"}}}}, {"uuid": "13e2dd00-cffc-4b7a-8ed9-55c3876df7bd", "name": "", "x": 38.762552303891766, "y": -122.35627912797126, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a54b2228-9e7d-4e6b-939d-ab2765454522", "name": "p1rlv486", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "13e2dd00-cffc-4b7a-8ed9-55c3876df7bd"}}}}, {"uuid": "4ee1cc19-733f-450e-b658-7f8074b32937", "name": "", "x": 38.75426623013744, "y": -122.36483936695494, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3e01a56d-1bfc-4169-9c3e-1373f9dbeb38", "name": "p1rdt281lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ee1cc19-733f-450e-b658-7f8074b32937"}}}}, {"uuid": "63783525-ad46-428b-b194-e5e2392a991c", "name": "", "x": 38.754777075984755, "y": -122.36484236876056, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be2d5799-907e-46fd-a389-120aea352775", "name": "p1rlv487", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "63783525-ad46-428b-b194-e5e2392a991c"}}}}, {"uuid": "e050f717-a215-4406-852a-29b4e392e4c5", "name": "", "x": 38.7537136313869, "y": -122.3648287764951, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "97c38794-7c60-4ff8-b09b-7503c9604409", "name": "p1rlv523", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e050f717-a215-4406-852a-29b4e392e4c5"}}}}, {"uuid": "3f49fa54-5e18-452b-ac04-7e82caec4a6b", "name": "", "x": 38.723225529795435, "y": -122.41097744489697, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7a8430e1-656f-4fe2-a11b-00adf429d75d", "name": "p1rdt297lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3f49fa54-5e18-452b-ac04-7e82caec4a6b"}}}}, {"uuid": "800c1fd5-f75b-4ea4-8955-de1e60878b43", "name": "", "x": 38.72307124027624, "y": -122.41075789575113, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bef074be-aac4-4d82-a832-641729756802", "name": "p1rlv524", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "800c1fd5-f75b-4ea4-8955-de1e60878b43"}}}}, {"uuid": "40ccb968-5212-4fa6-8793-3d76b678e286", "name": "", "x": 38.72334331826878, "y": -122.41110077065662, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3ab8e220-faf9-4108-80f8-22d2fe326c3d", "name": "p1rlv526", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "40ccb968-5212-4fa6-8793-3d76b678e286"}}}}, {"uuid": "429e93d6-a631-4ce5-9c3c-aa5a0aa6cedf", "name": "", "x": 38.72448847815554, "y": -122.41245231274745, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33e93250-9c11-4650-9469-412129855857", "name": "p1rdt298lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "429e93d6-a631-4ce5-9c3c-aa5a0aa6cedf"}}}}, {"uuid": "0688d8cc-a312-4660-8627-495ceab33df7", "name": "", "x": 38.72453056079826, "y": -122.41244798967669, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a42f8b99-82c6-4c90-81ea-6ccb38eacfab", "name": "p1rlv525", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0688d8cc-a312-4660-8627-495ceab33df7"}}}}, {"uuid": "fab5aa33-d64c-4dcc-b8ff-14c2773f63ad", "name": "", "x": 38.670540900167985, "y": -122.47976645470963, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6353ab92-f66f-47d8-97ac-058cf030ff82", "name": "p1rdt303lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fab5aa33-d64c-4dcc-b8ff-14c2773f63ad"}}}}, {"uuid": "9eb06290-2b92-41e0-9020-16bf69db06ca", "name": "", "x": 38.67056642076858, "y": -122.47972336691173, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32a1d9d7-31c7-4def-88d4-e4d41bd21572", "name": "p1rlv531", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9eb06290-2b92-41e0-9020-16bf69db06ca"}}}}, {"uuid": "8fb02675-4391-4938-a19f-1fd47ec0ceda", "name": "", "x": 38.67227127773109, "y": -122.47626596196271, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6a22ac71-bf3a-4016-86ce-fb25f471be5b", "name": "p1rdt304lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8fb02675-4391-4938-a19f-1fd47ec0ceda"}}}}, {"uuid": "98e5c374-ce1a-433a-8af6-cdab22541808", "name": "", "x": 38.67217810662493, "y": -122.4762166840671, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1362feeb-2e2c-4dd1-9f49-239c952c6120", "name": "p1rlv532", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "98e5c374-ce1a-433a-8af6-cdab22541808"}}}}, {"uuid": "b1b16ed0-c803-4ef8-af4d-bcfbdb7bd045", "name": "", "x": 38.67233171369118, "y": -122.47630752878543, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1f79bc5f-375f-4ecd-b828-eb7b137d7cab", "name": "p1rlv533", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b1b16ed0-c803-4ef8-af4d-bcfbdb7bd045"}}}}, {"uuid": "98bbd597-db60-4a2a-8e22-d8fd7c316c09", "name": "", "x": 38.67073161586084, "y": -122.47582091564139, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "90948977-fe1a-43b3-a8a4-86c080ae4906", "name": "p1rdt305lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "98bbd597-db60-4a2a-8e22-d8fd7c316c09"}}}}, {"uuid": "7f11a1c9-7fc0-498c-a911-6ffb6fc8d6be", "name": "", "x": 38.67104039312592, "y": -122.47571918109917, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0eb7074c-0745-4089-9329-aa3495f9b460", "name": "p1rlv534", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7f11a1c9-7fc0-498c-a911-6ffb6fc8d6be"}}}}, {"uuid": "ce2d9c5a-57c3-4ef1-b7d9-f4624daa6515", "name": "", "x": 38.67049996143512, "y": -122.47578059875961, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9cc91945-564c-4ace-bb53-77150b107b41", "name": "p1rlv535", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ce2d9c5a-57c3-4ef1-b7d9-f4624daa6515"}}}}, {"uuid": "58063c7b-e265-41f6-9754-559892ab8f15", "name": "", "x": 38.6707171128322, "y": -122.47597443436533, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d2ea78a8-b9c5-4760-b153-51b45565069e", "name": "p1rlv536", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "58063c7b-e265-41f6-9754-559892ab8f15"}}}}, {"uuid": "3a81837a-b6e1-4684-9525-903af091b574", "name": "", "x": 38.671226697580636, "y": -122.49048662526606, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "53eba878-66fa-4d30-8af4-1f583abe5f16", "name": "p1rdt306lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3a81837a-b6e1-4684-9525-903af091b574"}}}}, {"uuid": "31601fbd-a6ef-4c97-97da-e3c1cee1ddcf", "name": "", "x": 38.67124103844962, "y": -122.49053744844569, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9f2dfc9e-0b72-4465-b46a-d4e2a7a08f64", "name": "p1rlv537", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "31601fbd-a6ef-4c97-97da-e3c1cee1ddcf"}}}}, {"uuid": "1447dd15-b11d-4b92-aee8-fa7c9a86ea06", "name": "", "x": 38.685116671576026, "y": -122.45208329969167, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b8e448ea-e66d-4e16-80c0-8e742d7cac55", "name": "p1rdt335lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1447dd15-b11d-4b92-aee8-fa7c9a86ea06"}}}}, {"uuid": "20dab0fc-7fd8-4fca-bbe2-8c2946d2e18d", "name": "", "x": 38.68493681955931, "y": -122.45218585265648, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75628d41-a82d-4425-8aa2-9f377c771a4c", "name": "p1rlv588", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "20dab0fc-7fd8-4fca-bbe2-8c2946d2e18d"}}}}, {"uuid": "e11e5579-8701-4498-9418-0b99d6060f71", "name": "", "x": 38.6854049831095, "y": -122.45209030229843, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7a1c60be-f1a1-48d6-b396-4cca6d8c4e62", "name": "p1rlv589", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e11e5579-8701-4498-9418-0b99d6060f71"}}}}, {"uuid": "d9e96ec4-e74e-4618-9ee7-65d34c892888", "name": "", "x": 38.685061363444774, "y": -122.45183997708463, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "81ce208e-7244-418a-9867-b55b95ba0716", "name": "p1rlv590", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d9e96ec4-e74e-4618-9ee7-65d34c892888"}}}}, {"uuid": "10862e71-ec7d-4875-839a-324f8b84aa90", "name": "", "x": 38.68749417205864, "y": -122.45093337637859, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35993388-185f-4d1d-9dcb-16eb7556728f", "name": "p1rdt374lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10862e71-ec7d-4875-839a-324f8b84aa90"}}}}, {"uuid": "5987b6b3-bd40-4102-a885-a2b6b4a0a8d3", "name": "", "x": 38.687468186113925, "y": -122.45089073343217, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6e58890e-e6ce-4dda-91c0-5ccfdb5c420d", "name": "p1rlv657", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5987b6b3-bd40-4102-a885-a2b6b4a0a8d3"}}}}, {"uuid": "4b47f1f1-e215-42c1-aa5a-82bd5ed4ed38", "name": "", "x": 38.687021635585204, "y": -122.45201778533264, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d354e81e-b007-4bbe-b1db-50d7afacd0e0", "name": "p1rdt376lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4b47f1f1-e215-42c1-aa5a-82bd5ed4ed38"}}}}, {"uuid": "540e4606-3bc9-471d-b851-891dddd4bfbf", "name": "", "x": 38.68703599315794, "y": -122.452068611773, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "15751ee2-6783-472f-ad57-ec978234fec4", "name": "p1rlv660", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "540e4606-3bc9-471d-b851-891dddd4bfbf"}}}}, {"uuid": "b09e519e-2b26-438c-b80c-dc0e164fea9c", "name": "", "x": 38.67908332659903, "y": -122.51991969614502, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8569c197-174f-46ef-96c2-e0c674d7b046", "name": "p1rdt383lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b09e519e-2b26-438c-b80c-dc0e164fea9c"}}}}, {"uuid": "35e022ae-36d9-4824-88d4-cf5c8316580d", "name": "", "x": 38.67905736564, "y": -122.51987703293702, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eb25bf05-ce7f-405a-8c17-fd166748f7d3", "name": "p1rlv672", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "35e022ae-36d9-4824-88d4-cf5c8316580d"}}}}, {"uuid": "72ad716e-f1d2-48f5-a747-b3d15a844fd9", "name": "", "x": 38.679023967859024, "y": -122.52913908431695, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c56b4839-f007-4c9b-93a7-9147399f983f", "name": "p1rdt384lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "72ad716e-f1d2-48f5-a747-b3d15a844fd9"}}}}, {"uuid": "4cc9de64-df79-4551-84a0-ef1dbd2fec0c", "name": "", "x": 38.67837935182842, "y": -122.52878337051408, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "31d3267c-7020-4660-9a0b-49cd9d94a5d0", "name": "p1rlv673", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4cc9de64-df79-4551-84a0-ef1dbd2fec0c"}}}}, {"uuid": "17902503-2dce-426d-8ec3-66c36f03f7c9", "name": "", "x": 38.71691820009889, "y": -122.41937517163929, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "579c3e97-d1dc-4306-91e6-4cbbed29f882", "name": "p1rdt385lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "17902503-2dce-426d-8ec3-66c36f03f7c9"}}}}, {"uuid": "0575f243-1568-49fc-92d7-26cd6182fbca", "name": "", "x": 38.716892202729326, "y": -122.41933252291317, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "449992d6-a91b-40ea-9792-5166a5f2c849", "name": "p1rlv674", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0575f243-1568-49fc-92d7-26cd6182fbca"}}}}, {"uuid": "3a464616-ff46-4e66-bc71-73f7cb619077", "name": "", "x": 38.6691571170927, "y": -122.47438402684668, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "29a78735-964b-4381-bea0-01e5b1b79be9", "name": "p1rdt414lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3a464616-ff46-4e66-bc71-73f7cb619077"}}}}, {"uuid": "59455f0e-ff8f-4b31-b73e-898b6fbaf586", "name": "", "x": 38.669005790542414, "y": -122.47417070346637, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "93069f0f-fce7-47cd-b7b3-77e861f59573", "name": "p1rlv716", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59455f0e-ff8f-4b31-b73e-898b6fbaf586"}}}}, {"uuid": "4d4d97a1-ea59-48d6-b28a-5ea47726fe0d", "name": "", "x": 38.66935018999187, "y": -122.47460499537559, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1fdcbc55-681f-4fe5-8142-4945b25f6fef", "name": "p1rlv726", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d4d97a1-ea59-48d6-b28a-5ea47726fe0d"}}}}, {"uuid": "7488598b-5c4a-42eb-9cbf-5b2ea2c5d1db", "name": "", "x": 38.67353500851874, "y": -122.4699836494228, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "789d55de-619d-43cd-b056-ebe1be4c2dea", "name": "p1rdt415lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7488598b-5c4a-42eb-9cbf-5b2ea2c5d1db"}}}}, {"uuid": "8f512abc-7a0e-4beb-995e-afdea04ecb04", "name": "", "x": 38.67341206301482, "y": -122.47006900065233, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dd8fd159-f747-4ee4-a426-787f4eef4b42", "name": "p1rlv717", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8f512abc-7a0e-4beb-995e-afdea04ecb04"}}}}, {"uuid": "a5d9e4a8-f3b6-4cdb-9db1-c58f8b044a15", "name": "", "x": 38.673699700951325, "y": -122.46990593984998, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c3658479-7369-4bd9-be54-e7768c93a808", "name": "p1rlv724", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a5d9e4a8-f3b6-4cdb-9db1-c58f8b044a15"}}}}, {"uuid": "e0b96858-aa03-46db-b180-5ee0b94c7331", "name": "", "x": 38.67143528847217, "y": -122.47049470940273, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "473f5822-3412-4f3d-836e-f62314efa5b2", "name": "p1rdt416lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e0b96858-aa03-46db-b180-5ee0b94c7331"}}}}, {"uuid": "0afc18f9-d7cd-4f29-9b20-fee7da27741d", "name": "", "x": 38.67144963800081, "y": -122.4705455286412, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c4a1453b-98a3-4c2d-8ac2-c8b2ab1bfa4f", "name": "p1rlv718", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0afc18f9-d7cd-4f29-9b20-fee7da27741d"}}}}, {"uuid": "f4989904-872f-47d3-8701-93590820f835", "name": "", "x": 38.67352761620833, "y": -122.47084715807108, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "98bb09be-6506-49e8-8fd8-1a01d6861162", "name": "p1rdt417lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f4989904-872f-47d3-8701-93590820f835"}}}}, {"uuid": "e5c56170-5e6a-4e5e-93de-83a3668da549", "name": "", "x": 38.673541965589685, "y": -122.47089797885619, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d3153167-8b4c-40e4-abb7-3bdef86950c3", "name": "p1rlv719", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e5c56170-5e6a-4e5e-93de-83a3668da549"}}}}, {"uuid": "533f6e2a-609f-4f35-b833-e72a97fa7768", "name": "", "x": 38.669563658980074, "y": -122.47284200415966, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e189aaf-7650-49b4-83dd-94a29111aca2", "name": "p1rdt418lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "533f6e2a-609f-4f35-b833-e72a97fa7768"}}}}, {"uuid": "01cf012e-58c9-48bf-be58-f1427fe77a7e", "name": "", "x": 38.66958917702078, "y": -122.4727989145224, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cdbc11b7-5abf-4ff8-8d26-53faf4b1f3f5", "name": "p1rlv720", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "01cf012e-58c9-48bf-be58-f1427fe77a7e"}}}}, {"uuid": "203182a1-7f0b-4a5e-9a20-44d4dd2260c2", "name": "", "x": 38.67286897139167, "y": -122.46744763392057, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0d9603d6-5e5e-4cc0-aa86-1bdb80f7e1cf", "name": "p1rdt419lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "203182a1-7f0b-4a5e-9a20-44d4dd2260c2"}}}}, {"uuid": "43884182-507e-4cb3-964f-cbc372ccc34f", "name": "", "x": 38.67213944190893, "y": -122.46765283859665, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf12b67c-4df5-4dcb-a2e2-6ae2d0f82e65", "name": "p1rlv721", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "43884182-507e-4cb3-964f-cbc372ccc34f"}}}}, {"uuid": "398a58c5-8907-45e0-9604-09c0300e703e", "name": "", "x": 38.673435838033924, "y": -122.46736734084595, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7551be44-a4ca-4edb-b823-6495d163201e", "name": "p1rlv723", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "398a58c5-8907-45e0-9604-09c0300e703e"}}}}, {"uuid": "8c4e5f78-75c4-4283-98d4-ee2a1e884b43", "name": "", "x": 38.673174243579794, "y": -122.46731180115961, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b2bcbabc-a7fc-4230-8ec1-b6050af9cf58", "name": "p1rlv725", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8c4e5f78-75c4-4283-98d4-ee2a1e884b43"}}}}, {"uuid": "772b3248-d2cb-4f0b-ae16-539c1bc90128", "name": "", "x": 38.67078274236132, "y": -122.4676946740554, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "51673983-9230-421b-8501-bf71601b1b13", "name": "p1rdt420lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "772b3248-d2cb-4f0b-ae16-539c1bc90128"}}}}, {"uuid": "573c2087-0c8d-47da-9307-3efabbf971d7", "name": "", "x": 38.670756762481666, "y": -122.4676520348216, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4b7c6c65-e18c-4e79-b419-8894deb0d345", "name": "p1rlv722", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "573c2087-0c8d-47da-9307-3efabbf971d7"}}}}, {"uuid": "af8bd291-62f7-4b54-ba88-d62e96f0c893", "name": "", "x": 38.70121723278343, "y": -122.42203089954941, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "41f19802-32ca-4afc-8418-fe93e3ced1bb", "name": "p1rdt438lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "af8bd291-62f7-4b54-ba88-d62e96f0c893"}}}}, {"uuid": "b19a4f8f-5cf0-47ea-9609-4688e1df6de3", "name": "", "x": 38.70105000563393, "y": -122.4222662235864, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "80983704-a98f-46dc-a09f-700bd7df1a29", "name": "p1rlv749", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b19a4f8f-5cf0-47ea-9609-4688e1df6de3"}}}}, {"uuid": "4f2f25dd-3d70-420e-968d-3be4cdda8b52", "name": "", "x": 38.70143522055596, "y": -122.42180311856214, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b3c3b0fb-5a5d-439e-a350-b97ba0df41a0", "name": "p1rlv756", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4f2f25dd-3d70-420e-968d-3be4cdda8b52"}}}}, {"uuid": "4c670b17-732d-4dd3-98fc-a09595996303", "name": "", "x": 38.70124602203702, "y": -122.42077844448052, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bc7e7e51-f849-4bf4-b720-462daeb21932", "name": "p1rdt445lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c670b17-732d-4dd3-98fc-a09595996303"}}}}, {"uuid": "4ccd8de8-d3e4-446c-baf4-2b5f353790d1", "name": "", "x": 38.7012715204705, "y": -122.42073531744347, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e368704b-6c4b-4afb-a577-4b0d7a96dd65", "name": "p1rlv764", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ccd8de8-d3e4-446c-baf4-2b5f353790d1"}}}}, {"uuid": "1cc0b3d4-8021-4b32-8abb-e969a4fb62aa", "name": "", "x": 38.7015601074417, "y": -122.42258142494296, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0727e1f5-f2ca-4e19-9dc3-89e185002e52", "name": "p1rdt446lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1cc0b3d4-8021-4b32-8abb-e969a4fb62aa"}}}}, {"uuid": "c900b3f3-baf8-427c-8542-c5f2ffa1355a", "name": "", "x": 38.70157447780686, "y": -122.4226322555927, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "07381934-8e9b-4447-a330-e8af484331f1", "name": "p1rlv766", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c900b3f3-baf8-427c-8542-c5f2ffa1355a"}}}}, {"uuid": "4a885b64-5e1b-46ae-883a-62e3888a8c6a", "name": "", "x": 38.69708395346926, "y": -122.37425747756579, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "44f86829-17fc-4e83-b2a5-705454293161", "name": "p1rdt452lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4a885b64-5e1b-46ae-883a-62e3888a8c6a"}}}}, {"uuid": "918a6e1b-0380-4647-a2bd-aafaaf6b3a88", "name": "", "x": 38.69705554229972, "y": -122.37452973492258, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "180adab2-e49b-42e9-9aeb-42be0a7686c5", "name": "p1rlv786", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "918a6e1b-0380-4647-a2bd-aafaaf6b3a88"}}}}, {"uuid": "8dad0c31-e9b0-4799-b268-7c2874861bb7", "name": "", "x": 38.69721614595881, "y": -122.37422935064228, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b4fed6c4-6907-4601-9671-6f83d582dc45", "name": "p1rdm812", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8dad0c31-e9b0-4799-b268-7c2874861bb7"}}}}, {"uuid": "d3fc1810-0682-44c8-b0c8-c28ddb55de10", "name": "", "x": 38.69725422113334, "y": -122.3746085006707, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d00977fb-8d2a-44ca-aa9e-034894d6e280", "name": "p1rlv775", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d3fc1810-0682-44c8-b0c8-c28ddb55de10"}}}}, {"uuid": "75499f39-83de-43a8-a654-d945fb405baf", "name": "", "x": 38.6969100698522, "y": -122.37428951464027, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "090024f2-1724-4789-96da-174d1f5e65ec", "name": "p1rdm814", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "75499f39-83de-43a8-a654-d945fb405baf"}}}}, {"uuid": "a51d797c-e6f0-4b32-b7b9-c278c8b44c8c", "name": "", "x": 38.69694740684703, "y": -122.37453067672068, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4c5b1f75-47c0-45c3-9ef3-f97a445b242e", "name": "p1rlv776", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a51d797c-e6f0-4b32-b7b9-c278c8b44c8c"}}}}, {"uuid": "fa3c1915-fa2a-4d21-a0f6-6488b0414d01", "name": "", "x": 38.69672717493211, "y": -122.37432163006257, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d58e1471-844f-46ef-9d9a-43753b1dee25", "name": "p1rdt453lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa3c1915-fa2a-4d21-a0f6-6488b0414d01"}}}}, {"uuid": "fea9bebc-eef7-4fe5-b640-a25baff0a50c", "name": "", "x": 38.696649943652076, "y": -122.37428890620298, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ecd0e9ae-cbf4-4435-8a57-ad23e3e037b4", "name": "p1rdm815", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fea9bebc-eef7-4fe5-b640-a25baff0a50c"}}}}, {"uuid": "566e28aa-36fb-42ab-a68d-202b695174ed", "name": "", "x": 38.69663225777152, "y": -122.37457941885675, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "def7e507-cb62-42f5-8451-b8a742ef4eb2", "name": "p1rlv819", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "566e28aa-36fb-42ab-a68d-202b695174ed"}}}}, {"uuid": "7d2179fa-de53-465f-87d5-363053bbc7d5", "name": "", "x": 38.70111870876331, "y": -122.37432184237016, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d2e41779-98fa-453d-b4df-10a5dd61a4b5", "name": "p1rdm816", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7d2179fa-de53-465f-87d5-363053bbc7d5"}}}}, {"uuid": "3eef0e56-9c2d-4b51-ba64-e4b46a209297", "name": "", "x": 38.70112000065753, "y": -122.37456333253593, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6fb1fca8-7985-4356-a8de-7433fef7a454", "name": "p1rlv777", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3eef0e56-9c2d-4b51-ba64-e4b46a209297"}}}}, {"uuid": "253db7aa-5fce-4b55-9ec6-020f592f3b00", "name": "", "x": 38.70157181887224, "y": -122.3742643698461, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0b3e7941-9bdd-48f9-a4a5-a553da9bbb57", "name": "p1rdt454lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "253db7aa-5fce-4b55-9ec6-020f592f3b00"}}}}, {"uuid": "2d928d67-5f6a-413b-ae62-6f67424a1c6d", "name": "", "x": 38.70172394100054, "y": -122.37459257247573, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "87e4ddc3-ccc3-48af-bc35-d7d85f324ee7", "name": "p1rdm817", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2d928d67-5f6a-413b-ae62-6f67424a1c6d"}}}}, {"uuid": "b22926f4-6b7d-47e3-ae23-fadd82a8b5ac", "name": "", "x": 38.701795539168316, "y": -122.37449994744384, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e9ce2439-fcc7-4965-81ee-f875db83b003", "name": "p1rlv789", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b22926f4-6b7d-47e3-ae23-fadd82a8b5ac"}}}}, {"uuid": "66477536-d6bd-43e1-8c9e-745b5321f80e", "name": "", "x": 38.7013420827754, "y": -122.37396339276478, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bf188897-9db5-4ff4-8c5b-5932a8a794cf", "name": "p1rdm818", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "66477536-d6bd-43e1-8c9e-745b5321f80e"}}}}, {"uuid": "23378020-dbad-4f0d-b057-ffe4e0117567", "name": "", "x": 38.70145818262173, "y": -122.37376687845641, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3126c61-9602-45cf-8d57-27d26c14ca7e", "name": "p1rlv800", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "23378020-dbad-4f0d-b057-ffe4e0117567"}}}}, {"uuid": "846a1025-c69e-451f-9377-15537603c6e1", "name": "", "x": 38.70201519147799, "y": -122.37513054558815, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b757a90a-ade8-486f-90f1-e7c5e13708ba", "name": "p1rdm819", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "846a1025-c69e-451f-9377-15537603c6e1"}}}}, {"uuid": "fc9c2527-9baf-4404-96ae-ee464d18a789", "name": "", "x": 38.70182669191501, "y": -122.37527018819917, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "80d58665-ee8a-4f4e-a906-dc15aa3d8c6f", "name": "p1rlv778", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fc9c2527-9baf-4404-96ae-ee464d18a789"}}}}, {"uuid": "ce8a26f6-92ff-436e-bfa0-57e400e499d7", "name": "", "x": 38.7019178147915, "y": -122.37492836596363, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "53b40b3c-db5a-4fa0-bedb-f293c6eac473", "name": "p1rdt455lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ce8a26f6-92ff-436e-bfa0-57e400e499d7"}}}}, {"uuid": "87337660-1d35-46ef-9aa5-4733c6572e85", "name": "", "x": 38.70180590348404, "y": -122.37475286106623, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ea28f170-6bf0-47f7-a089-8375dff2ad4a", "name": "p1rdm820", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "87337660-1d35-46ef-9aa5-4733c6572e85"}}}}, {"uuid": "43ef4919-06d3-41a8-a235-9fbe88ea5687", "name": "", "x": 38.701671533532036, "y": -122.37490353316474, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d0089ee3-0cb4-434c-adc4-c91a8441ef0a", "name": "p1rlv787", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "43ef4919-06d3-41a8-a235-9fbe88ea5687"}}}}, {"uuid": "29077723-8ec8-453b-8c57-cdfce7b38831", "name": "", "x": 38.70149204551021, "y": -122.37504309725601, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "052949b1-9e85-4be7-993c-9e97efda3657", "name": "p1rlv811", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "29077723-8ec8-453b-8c57-cdfce7b38831"}}}}, {"uuid": "2c30f199-abfe-4d48-b1ca-b49cf7589e41", "name": "", "x": 38.69874038147765, "y": -122.37499407083057, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6abe982-a205-4607-bacf-08e9d7cb6f54", "name": "p1rdt456lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2c30f199-abfe-4d48-b1ca-b49cf7589e41"}}}}, {"uuid": "dd0efdae-a64f-41af-ba64-43b865c65806", "name": "", "x": 38.6988698234033, "y": -122.37507741848081, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33492e0f-c907-46c6-a529-503480b642bb", "name": "p1rlv837", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dd0efdae-a64f-41af-ba64-43b865c65806"}}}}, {"uuid": "0199de53-9365-434d-aa43-d2c1589ff2db", "name": "", "x": 38.69908332769086, "y": -122.37455807209501, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e3cae47a-4077-44e6-9761-fc30d85c3442", "name": "p1rdm822", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0199de53-9365-434d-aa43-d2c1589ff2db"}}}}, {"uuid": "e7862db2-6252-4c87-8f40-cc4b08525a6b", "name": "", "x": 38.699192938897575, "y": -122.3748331116339, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fbc761bf-480c-465c-9479-279832c50bc2", "name": "p1rlv779", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e7862db2-6252-4c87-8f40-cc4b08525a6b"}}}}, {"uuid": "fde861ab-384e-4d57-9c4b-8d29c452a1a4", "name": "", "x": 38.69872582718306, "y": -122.37511317064184, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "84ca6719-0bbc-440a-b0eb-23b8f32dcf47", "name": "p1rdm823", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fde861ab-384e-4d57-9c4b-8d29c452a1a4"}}}}, {"uuid": "a276efc9-12d7-4647-8126-ba4bf608023b", "name": "", "x": 38.69852447935862, "y": -122.37506494784137, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be4b6c4e-78d0-4c8e-907c-619f1e43c149", "name": "p1rlv831", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a276efc9-12d7-4647-8126-ba4bf608023b"}}}}, {"uuid": "dc7c9480-fff2-4481-9abb-71107106b522", "name": "", "x": 38.69449656825178, "y": -122.37575189359077, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "866745cc-62c9-429f-8389-fcc5a1710f17", "name": "p1rdt457lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dc7c9480-fff2-4481-9abb-71107106b522"}}}}, {"uuid": "fa6c14d6-12bd-4418-bb7c-5b75aabf228d", "name": "", "x": 38.69441132364952, "y": -122.37550717957821, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "20dcf67f-f04f-498a-830d-557ba7b4d867", "name": "p1rlv780", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa6c14d6-12bd-4418-bb7c-5b75aabf228d"}}}}, {"uuid": "845013de-0fa5-4507-86c0-0171eb46dab6", "name": "", "x": 38.694628638419935, "y": -122.3757007735009, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bf7e29df-0880-4c8c-aa5c-c43f24dd820e", "name": "p1rdm826", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "845013de-0fa5-4507-86c0-0171eb46dab6"}}}}, {"uuid": "4c292e42-91c1-425c-ab9d-78892c7e4836", "name": "", "x": 38.694609633506126, "y": -122.37551695428785, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2d1a96d5-f971-4116-9642-769ef5b97e7c", "name": "p1rlv783", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c292e42-91c1-425c-ab9d-78892c7e4836"}}}}, {"uuid": "be8d4ef3-4f9e-4921-94e3-a481ca49b2ff", "name": "", "x": 38.69466560426392, "y": -122.3758729377002, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eb137176-0642-4d87-ae40-1b7b0e1cb214", "name": "p1rlv795", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be8d4ef3-4f9e-4921-94e3-a481ca49b2ff"}}}}, {"uuid": "1a861ef0-a169-461f-abde-6f601141ce10", "name": "", "x": 38.694926011094644, "y": -122.37569818860291, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8fafab6a-7d1c-4b87-94b3-5bc4d09ff95d", "name": "p1rdm827", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1a861ef0-a169-461f-abde-6f601141ce10"}}}}, {"uuid": "01722373-7ba3-4bf0-a6df-8a4d2d2d63d4", "name": "", "x": 38.69489143888521, "y": -122.37597446682435, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3fe9bb3f-e3c1-4b59-b39f-f62271a55bdd", "name": "p1rlv791", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "01722373-7ba3-4bf0-a6df-8a4d2d2d63d4"}}}}, {"uuid": "9fc67f87-3522-4d69-a9a3-b9248ad5e601", "name": "", "x": 38.694187760198, "y": -122.37583109428404, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dc2d45e2-caa5-4f7d-976e-ccb045c30559", "name": "p1rdm829", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9fc67f87-3522-4d69-a9a3-b9248ad5e601"}}}}, {"uuid": "719b05d2-eba8-4118-9171-d1406b60336f", "name": "", "x": 38.694161769492204, "y": -122.3760268023747, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1ecc45b2-1fbe-4a31-995f-e2f8fffe61a7", "name": "p1rlv801", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "719b05d2-eba8-4118-9171-d1406b60336f"}}}}, {"uuid": "b6e99fb2-ec36-4ae6-9455-b941776f70f0", "name": "", "x": 38.69415358661105, "y": -122.37565138406234, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "11064c6f-3b7a-43b5-96ca-7ef96be3815e", "name": "p1rlv817", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b6e99fb2-ec36-4ae6-9455-b941776f70f0"}}}}, {"uuid": "f55d31ca-bc69-454e-8549-05d666f255d3", "name": "", "x": 38.695030276964474, "y": -122.37497283941411, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c668ab72-249e-4463-a3b4-863c7fe826c1", "name": "p1rdm831", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f55d31ca-bc69-454e-8549-05d666f255d3"}}}}, {"uuid": "ba483e47-e191-4d8f-aa43-0cdc306972f9", "name": "", "x": 38.69496811967224, "y": -122.37514586658888, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "98c5ba15-a339-478a-a79f-9298fab16a54", "name": "p1rlv781", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ba483e47-e191-4d8f-aa43-0cdc306972f9"}}}}, {"uuid": "b26f7ad4-878d-4d83-a117-65a1974f593c", "name": "", "x": 38.69490966180515, "y": -122.37485492226794, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "67e071ab-e3dc-4779-9e81-585547cd22ca", "name": "p1rdt458lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b26f7ad4-878d-4d83-a117-65a1974f593c"}}}}, {"uuid": "1c4ced69-d921-431e-a0ed-4f7bda33c6ce", "name": "", "x": 38.69482154193585, "y": -122.37469867853063, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "92f03cbf-2585-4e0e-ab0a-cda0b267b34d", "name": "p1rdm832", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1c4ced69-d921-431e-a0ed-4f7bda33c6ce"}}}}, {"uuid": "1da019c9-03b8-4947-aabc-fe8b39b50d8d", "name": "", "x": 38.69478038429, "y": -122.37489849683361, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c3bc013f-c78d-4a3c-b27f-826c3025de0e", "name": "p1rlv843", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1da019c9-03b8-4947-aabc-fe8b39b50d8d"}}}}, {"uuid": "379cb4d3-78c7-4221-af0f-e1a5b188a4bb", "name": "", "x": 38.701681041918285, "y": -122.37384145943425, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9eb57d99-ae80-43da-b0cb-b26bdd583e1a", "name": "p1rdt459lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "379cb4d3-78c7-4221-af0f-e1a5b188a4bb"}}}}, {"uuid": "e4637786-72a5-4382-96af-a9d4bb9b3ddd", "name": "", "x": 38.7019010899339, "y": -122.37401601985513, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "78a4f54a-017a-41b0-85c8-b3e408c21c08", "name": "p1rlv782", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e4637786-72a5-4382-96af-a9d4bb9b3ddd"}}}}, {"uuid": "77846b24-5292-42be-bdfc-2dd8cb5fe3f7", "name": "", "x": 38.70217626105635, "y": -122.37544717401559, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "028bc055-0ee6-4729-8cd2-15bd7153f975", "name": "p1rdt460lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "77846b24-5292-42be-bdfc-2dd8cb5fe3f7"}}}}, {"uuid": "b26c164b-bd1d-4e3b-b693-7687b88241a5", "name": "", "x": 38.70212578404628, "y": -122.37558959231082, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2823b5b9-bcc3-4b30-9874-89dc33ec80d2", "name": "p1rlv784", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b26c164b-bd1d-4e3b-b693-7687b88241a5"}}}}, {"uuid": "10c6883a-43b8-4c15-b651-d1ef7659c9b6", "name": "", "x": 38.702286881592116, "y": -122.37538118676348, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9b1c34f1-2613-46aa-9a9f-686ee518e559", "name": "p1rlv797", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10c6883a-43b8-4c15-b651-d1ef7659c9b6"}}}}, {"uuid": "b4b4ec33-db46-469e-a833-d5e498acc9ff", "name": "", "x": 38.702257020866284, "y": -122.37485243501904, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "790d0b88-fed2-4c90-bfdf-44d3c31d3d8d", "name": "p1rdm837", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b4b4ec33-db46-469e-a833-d5e498acc9ff"}}}}, {"uuid": "8295e92c-cbac-4f52-982a-bf37131d64d8", "name": "", "x": 38.70215746639765, "y": -122.37477280015747, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0d9f269a-e476-4b82-a258-479d812d008d", "name": "p1rlv806", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8295e92c-cbac-4f52-982a-bf37131d64d8"}}}}, {"uuid": "b98023ea-f8a2-432c-81a7-f05c1eec5f47", "name": "", "x": 38.702419502723, "y": -122.37467564114138, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e0e1d710-2ab1-43ca-a7c1-8f05a6c0b753", "name": "p1rdm835", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b98023ea-f8a2-432c-81a7-f05c1eec5f47"}}}}, {"uuid": "3396a052-4e10-4614-970a-e52b38290a46", "name": "", "x": 38.702500140978806, "y": -122.37481581739344, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "59662cef-c126-4188-ad86-844f6cabaf34", "name": "p1rlv796", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3396a052-4e10-4614-970a-e52b38290a46"}}}}, {"uuid": "e7917d2d-5f0a-4c8d-8ea2-3fd31c3312ae", "name": "", "x": 38.702324093645906, "y": -122.3755993680085, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "83fdcccd-6a26-4311-aad3-da67dac5af42", "name": "p1rdm838", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e7917d2d-5f0a-4c8d-8ea2-3fd31c3312ae"}}}}, {"uuid": "076990c7-d743-4fbb-89e1-5ebc4b093ce1", "name": "", "x": 38.70238649707223, "y": -122.37547232235222, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fb4a881f-684d-48e4-a6f0-5832f73d140a", "name": "p1rlv810", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "076990c7-d743-4fbb-89e1-5ebc4b093ce1"}}}}, {"uuid": "46076791-3910-4848-af07-6360ab1902cb", "name": "", "x": 38.70245104977729, "y": -122.37574776762911, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "344c24ef-9d54-4c1a-9aa4-852a76ddbec7", "name": "p1rdm839", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "46076791-3910-4848-af07-6360ab1902cb"}}}}, {"uuid": "364fe691-43cc-4586-8fbb-f3eed45bd625", "name": "", "x": 38.702223773417444, "y": -122.37590677054554, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d7ce197c-cee4-40df-b1d7-be13f1be8bb1", "name": "p1rlv822", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "364fe691-43cc-4586-8fbb-f3eed45bd625"}}}}, {"uuid": "69fe6bcf-63e7-4326-8de4-0eb763d1cef8", "name": "", "x": 38.70257800572197, "y": -122.37589616777406, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f0649432-ddb6-4648-8efe-27ee1fd959e4", "name": "p1rdm840", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "69fe6bcf-63e7-4326-8de4-0eb763d1cef8"}}}}, {"uuid": "e3ed841d-238a-473c-a6d8-4520609914f3", "name": "", "x": 38.70249776336369, "y": -122.37605786929961, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48e97be9-1f80-457f-a56e-79f54458c620", "name": "p1rlv839", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e3ed841d-238a-473c-a6d8-4520609914f3"}}}}, {"uuid": "fb47db4c-2eb8-46db-9d85-36ca6f7eac85", "name": "", "x": 38.69757588310151, "y": -122.37577864853107, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "505b390e-ffd3-482a-8ae9-b8d6bd8be94f", "name": "p1rdm841", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fb47db4c-2eb8-46db-9d85-36ca6f7eac85"}}}}, {"uuid": "7a77042f-fabf-48ca-b7bc-e10792c76c69", "name": "", "x": 38.69764123251456, "y": -122.37620356241798, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fa98d6c6-7086-4033-a9af-c0a33e802942", "name": "p1rlv785", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7a77042f-fabf-48ca-b7bc-e10792c76c69"}}}}, {"uuid": "f5f55bde-5e43-4018-86ad-8b885d9136a3", "name": "", "x": 38.697416472212836, "y": -122.37577251090494, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fd9a4931-435b-4b48-907c-024c0b8a4816", "name": "p1rdt461lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5f55bde-5e43-4018-86ad-8b885d9136a3"}}}}, {"uuid": "ebe1a657-73a9-459f-b0e0-fec2ca16456a", "name": "", "x": 38.69704403287731, "y": -122.37574877318404, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "172dd9d0-eab4-4481-9edd-f868e6ed87d9", "name": "p1rdm842", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ebe1a657-73a9-459f-b0e0-fec2ca16456a"}}}}, {"uuid": "3ccc8255-f565-4d1d-a03a-3ea1fc03d740", "name": "", "x": 38.69698334699525, "y": -122.37619777752667, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0e8c4bc9-0688-43e6-93a8-9664c9b618b7", "name": "p1rlv793", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3ccc8255-f565-4d1d-a03a-3ea1fc03d740"}}}}, {"uuid": "c0565ae7-3fec-4631-b6f3-a84c739859a2", "name": "", "x": 38.702201293623176, "y": -122.37338841314656, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d96f458-607c-4820-90b1-6fb2625ace7f", "name": "p1rdt462lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c0565ae7-3fec-4631-b6f3-a84c739859a2"}}}}, {"uuid": "117ffc96-232e-4015-aac7-6296e312ddff", "name": "", "x": 38.70221229583861, "y": -122.37323129022502, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bf42fa7f-370e-400e-8f6d-76eb8c70ecb9", "name": "p1rlv790", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "117ffc96-232e-4015-aac7-6296e312ddff"}}}}, {"uuid": "66ee1141-41be-44d4-b986-8ebb97d5a851", "name": "", "x": 38.702384188075854, "y": -122.3733562927121, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3ac64728-e64c-4241-8a3f-b884f11c6393", "name": "p1rdm843", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "66ee1141-41be-44d4-b986-8ebb97d5a851"}}}}, {"uuid": "860e4eab-613f-40e5-be26-b497bf4248c4", "name": "", "x": 38.70231135824942, "y": -122.37321892523424, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c9f470d9-6ead-4413-ad8a-7ccc69ae9237", "name": "p1rlv788", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "860e4eab-613f-40e5-be26-b497bf4248c4"}}}}, {"uuid": "dd8c6bac-9564-42dc-9c64-f3f6da327a3c", "name": "", "x": 38.7025463910665, "y": -122.37335487708582, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2086cded-e13c-4683-824e-9e15f99e12e8", "name": "p1rdm846", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dd8c6bac-9564-42dc-9c64-f3f6da327a3c"}}}}, {"uuid": "4c0f531e-29cb-4717-b893-ab2bbcda29c3", "name": "", "x": 38.70252953923245, "y": -122.37357352972886, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6e2a8871-7bc4-497f-9954-38db92cb3eba", "name": "p1rlv864", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c0f531e-29cb-4717-b893-ab2bbcda29c3"}}}}, {"uuid": "c59df0b4-eab3-43e2-9baa-fb2da89819cf", "name": "", "x": 38.702105331447335, "y": -122.37345072820672, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b4620a0-c781-422e-8cc7-3ceed9a0c8dc", "name": "p1rdm845", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c59df0b4-eab3-43e2-9baa-fb2da89819cf"}}}}, {"uuid": "f1970de7-55c0-4d65-a1ad-1d38a4180337", "name": "", "x": 38.70188944897217, "y": -122.37299658085036, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "024961c3-25f4-4a15-a52a-7f88dc652766", "name": "p1rlv840", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f1970de7-55c0-4d65-a1ad-1d38a4180337"}}}}, {"uuid": "c6c1d19e-c4b9-419a-a813-bc297120bd26", "name": "", "x": 38.702162992217495, "y": -122.3735922043492, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "abdfa5db-c398-4638-805d-6d55597e1921", "name": "p1rlv865", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c6c1d19e-c4b9-419a-a813-bc297120bd26"}}}}, {"uuid": "b294bc07-25bb-471e-adef-295df19ea6ae", "name": "", "x": 38.702251051988306, "y": -122.37373696284877, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1a7cca48-fd4b-4630-a479-55f2b6ada03b", "name": "p1rlv867", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b294bc07-25bb-471e-adef-295df19ea6ae"}}}}, {"uuid": "4ee440dd-1144-418b-b9e5-686ac95fe047", "name": "", "x": 38.70003035932669, "y": -122.37586478778037, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f660c35e-85f8-4f0e-b03b-806006c76c67", "name": "p1rdt463lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ee440dd-1144-418b-b9e5-686ac95fe047"}}}}, {"uuid": "6c8c6605-54a0-4f74-a558-cea62a6e6755", "name": "", "x": 38.7000284875326, "y": -122.37604482598387, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f806232e-0a52-46d5-80f7-7ea3a914137a", "name": "p1rlv792", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c8c6605-54a0-4f74-a558-cea62a6e6755"}}}}, {"uuid": "a1a9621f-11fc-426f-87dd-3d67019f0b3b", "name": "", "x": 38.699938225668625, "y": -122.37578973798107, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c397a5a5-21bc-4f4d-9f24-7af1219b70e7", "name": "p1rdm850", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a1a9621f-11fc-426f-87dd-3d67019f0b3b"}}}}, {"uuid": "28e708f2-3c1d-404d-8dcb-ecb29b51303c", "name": "", "x": 38.69980443234621, "y": -122.37627677000896, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bada1117-5605-4aec-9314-8013ed243e3c", "name": "p1rlv860", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "28e708f2-3c1d-404d-8dcb-ecb29b51303c"}}}}, {"uuid": "21cd6750-0958-4f0b-9fd8-b9f9372c0348", "name": "", "x": 38.69546877867281, "y": -122.373869079739, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "749e07aa-74ce-40f2-a352-9c55f9914377", "name": "p1rdt464lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "21cd6750-0958-4f0b-9fd8-b9f9372c0348"}}}}, {"uuid": "65f83ebc-aea0-429a-a6b4-dc69a6e34403", "name": "", "x": 38.6953493322175, "y": -122.37396963727394, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4eecc456-41af-4242-ab30-d8ca45d55a2c", "name": "p1rlv794", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65f83ebc-aea0-429a-a6b4-dc69a6e34403"}}}}, {"uuid": "efde92d7-4f87-4aa8-833a-398f86a5bcd0", "name": "", "x": 38.69564655774635, "y": -122.37393116894758, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "17b42dae-f856-4945-ba7a-9d3f47e049fe", "name": "p1rdm852", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "efde92d7-4f87-4aa8-833a-398f86a5bcd0"}}}}, {"uuid": "ede6db0e-440b-4e2d-8435-9539c4f9fe4c", "name": "", "x": 38.69550381660122, "y": -122.37420977320264, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d209dff6-7a24-41ef-947a-8c6f79c2d65c", "name": "p1rlv825", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ede6db0e-440b-4e2d-8435-9539c4f9fe4c"}}}}, {"uuid": "6c196105-5de5-4ebf-8534-5b9673501c2d", "name": "", "x": 38.69529421784077, "y": -122.37377463240384, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "08c93f8a-9600-4ffd-8e18-576d433ce777", "name": "p1rdm853", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c196105-5de5-4ebf-8534-5b9673501c2d"}}}}, {"uuid": "00f12ce4-6279-4f7f-b351-ef6b4d9d1895", "name": "", "x": 38.6954016143038, "y": -122.37363570614771, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8e3a1bd0-69fe-42bb-993d-2094ecc658ce", "name": "p1rlv829", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "00f12ce4-6279-4f7f-b351-ef6b4d9d1895"}}}}, {"uuid": "a12d289b-3eb4-436f-9fcb-4e06e31acedf", "name": "", "x": 38.6980078724581, "y": -122.37567139741331, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d5ad091a-3b6a-4069-a642-104c28a94dc4", "name": "p1rdm855", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a12d289b-3eb4-436f-9fcb-4e06e31acedf"}}}}, {"uuid": "e1b7c1d6-d5c9-416e-b644-68ca8ac89c67", "name": "", "x": 38.69804305798535, "y": -122.3755100974583, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e0f8ee8-795f-4bea-bf7a-e2c477eefb89", "name": "p1rlv809", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e1b7c1d6-d5c9-416e-b644-68ca8ac89c67"}}}}, {"uuid": "5f783c36-4d6c-46a7-a596-a1775597daf0", "name": "", "x": 38.69840981645937, "y": -122.37572585292882, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "433b0872-49c4-452c-941c-8083a72840ce", "name": "p1rdt465lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5f783c36-4d6c-46a7-a596-a1775597daf0"}}}}, {"uuid": "e28eaec9-f284-4eaf-8033-7359f6a39638", "name": "", "x": 38.69867415513827, "y": -122.37556210766509, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eaf112db-b9dc-4d90-b030-3e26188aaf2b", "name": "p1rdm856", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e28eaec9-f284-4eaf-8033-7359f6a39638"}}}}, {"uuid": "6f275d6c-b659-4a8f-9701-15a2f8ced9bc", "name": "", "x": 38.69855682418657, "y": -122.37552862894972, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d5e2c3a2-32c0-4bb9-9802-265cec784974", "name": "p1rlv862", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6f275d6c-b659-4a8f-9701-15a2f8ced9bc"}}}}, {"uuid": "13e20615-a6e4-4635-9781-ad96b92e29cd", "name": "", "x": 38.6988553632223, "y": -122.37574452723823, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eb73d9f2-aefb-430c-babd-ac02422eb212", "name": "p1rdm854", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "13e20615-a6e4-4635-9781-ad96b92e29cd"}}}}, {"uuid": "b48c379e-4147-4789-8a0b-4f78bd953f0b", "name": "", "x": 38.69885849252648, "y": -122.3763309850566, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c30005d7-7e42-4a08-8935-0c7227fba4a6", "name": "p1rlv798", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b48c379e-4147-4789-8a0b-4f78bd953f0b"}}}}, {"uuid": "b9e5cf5a-e99c-413d-b8a9-d68c8495cc17", "name": "", "x": 38.697834262777405, "y": -122.37522442460597, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c274aa99-a566-4915-83af-7115bec586b1", "name": "p1rdm857", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b9e5cf5a-e99c-413d-b8a9-d68c8495cc17"}}}}, {"uuid": "d06026e0-9130-4360-96b9-adbed16f39bd", "name": "", "x": 38.69763601444608, "y": -122.37522614936233, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6f706d9d-0cb1-453b-9ca5-377f7d766099", "name": "p1rlv799", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d06026e0-9130-4360-96b9-adbed16f39bd"}}}}, {"uuid": "d3d04da5-e3f9-4ba5-96af-05e7b20a1b7b", "name": "", "x": 38.69792563161655, "y": -122.37492861747332, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f422478c-0d77-48c8-87fb-e883d945f8a6", "name": "p1rdt466lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d3d04da5-e3f9-4ba5-96af-05e7b20a1b7b"}}}}, {"uuid": "6a7949b0-112b-4610-a8e8-2178e83b8af6", "name": "", "x": 38.69756758613625, "y": -122.37422628827595, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "caa7d639-522c-4fd6-8b74-73a337bd67d2", "name": "p1rdm858", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a7949b0-112b-4610-a8e8-2178e83b8af6"}}}}, {"uuid": "be08b287-4bce-4f87-b15e-4e011958954e", "name": "", "x": 38.69752942558697, "y": -122.37436063848634, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7a134556-828b-4e0c-8773-2f207802e33a", "name": "p1rlv815", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be08b287-4bce-4f87-b15e-4e011958954e"}}}}, {"uuid": "11ac6b38-60a5-49b9-8a0a-540db3fefb3c", "name": "", "x": 38.694252540223, "y": -122.37330828127818, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "23ed76af-dcb2-4333-ae4c-d7439a37cf87", "name": "p1rdt467lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "11ac6b38-60a5-49b9-8a0a-540db3fefb3c"}}}}, {"uuid": "d1963ecf-1914-499a-8472-b5247aebbf28", "name": "", "x": 38.69427815650523, "y": -122.37304358141793, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b2436086-d5c4-4b70-a402-e7d1b6f5b77e", "name": "p1rlv802", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1963ecf-1914-499a-8472-b5247aebbf28"}}}}, {"uuid": "3be967c7-0670-4f96-b81c-c29550a7414c", "name": "", "x": 38.695512481684965, "y": -122.37583108066667, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3a4bf0e0-92f0-4cd9-afc5-65d9ed242271", "name": "p1rdm861", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3be967c7-0670-4f96-b81c-c29550a7414c"}}}}, {"uuid": "efeb21c5-4624-459c-9e98-5cc05610708d", "name": "", "x": 38.69558659678035, "y": -122.3762099095591, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "81802469-7320-47e9-b826-fbb33bd371ab", "name": "p1rlv823", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "efeb21c5-4624-459c-9e98-5cc05610708d"}}}}, {"uuid": "033a2a11-14fb-4987-9143-4c5ea81d6861", "name": "", "x": 38.695386323591904, "y": -122.37583217708425, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3bfca289-c04c-45d9-8104-40089fc1737e", "name": "p1rdm860", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "033a2a11-14fb-4987-9143-4c5ea81d6861"}}}}, {"uuid": "a8f165ab-776e-40e3-8147-22b245234707", "name": "", "x": 38.6953513829787, "y": -122.3760394653489, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "018c978c-5673-4090-9792-b75ee161f6d2", "name": "p1rlv803", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8f165ab-776e-40e3-8147-22b245234707"}}}}, {"uuid": "a29fd963-e063-4256-9052-473ca445a911", "name": "", "x": 38.69564629017529, "y": -122.3756964667581, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b368fb8f-7f4d-4558-b6b2-2e1db4087727", "name": "p1rdt468lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a29fd963-e063-4256-9052-473ca445a911"}}}}, {"uuid": "f35e8328-37b1-44a2-a763-afa113575634", "name": "", "x": 38.696223821296954, "y": -122.37572140485321, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1daf402d-faec-4230-b4ab-1efa6283ac0f", "name": "p1rdm862", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f35e8328-37b1-44a2-a763-afa113575634"}}}}, {"uuid": "0c90b1a8-53a5-4b65-b599-aa1c94439206", "name": "", "x": 38.696252021310734, "y": -122.37593964620868, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2eb57fc4-636d-4923-9f4a-d308b062599f", "name": "p1rlv833", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0c90b1a8-53a5-4b65-b599-aa1c94439206"}}}}, {"uuid": "4c5c36ba-98c8-4540-bd20-b43167f47a63", "name": "", "x": 38.69464965312743, "y": -122.37341980651155, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d12ab15f-746d-462b-b395-e2b330ba1226", "name": "p1rdt469lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c5c36ba-98c8-4540-bd20-b43167f47a63"}}}}, {"uuid": "a5345d32-563a-4acd-b251-ba5e631ee422", "name": "", "x": 38.6946876894052, "y": -122.37326246422553, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0475b34e-14ab-48e4-9df7-7444de1cde7d", "name": "p1rlv805", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a5345d32-563a-4acd-b251-ba5e631ee422"}}}}, {"uuid": "087c125b-3c1d-4629-a9c6-0573dbf2e0c5", "name": "", "x": 38.70251978737086, "y": -122.37458961698891, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "15ab2647-a801-4cb5-a1f7-528118ff5dea", "name": "p1rdt470lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "087c125b-3c1d-4629-a9c6-0573dbf2e0c5"}}}}, {"uuid": "689170c1-88d4-43af-91c5-010c0ce51404", "name": "", "x": 38.70270494012969, "y": -122.37435402129528, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ab33ce2f-3131-4cfb-8df2-329fb4aa76b7", "name": "p1rlv858", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "689170c1-88d4-43af-91c5-010c0ce51404"}}}}, {"uuid": "f578b711-1e16-41bc-aea1-727982d2a44c", "name": "", "x": 38.70236818204675, "y": -122.3747179490724, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d861761c-3fe7-437d-917d-8beb24318a42", "name": "p1rdm864", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f578b711-1e16-41bc-aea1-727982d2a44c"}}}}, {"uuid": "186932a4-38ef-4136-bf3f-59f1cf536dfd", "name": "", "x": 38.702215723425525, "y": -122.37440030860232, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aa259be8-8a61-461a-9e58-d4aaf1ce82db", "name": "p1rlv807", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "186932a4-38ef-4136-bf3f-59f1cf536dfd"}}}}, {"uuid": "0a7684b2-4e2a-4be3-aaf0-80e9592fb790", "name": "", "x": 38.701111976317726, "y": -122.37359342043746, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "40d98c0b-4c66-4581-9553-f5f57c4b27b9", "name": "p1rdt471lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a7684b2-4e2a-4be3-aaf0-80e9592fb790"}}}}, {"uuid": "85ea6224-1682-4dce-aec8-40cb358842c6", "name": "", "x": 38.7012040803456, "y": -122.37343559224011, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "06746d4d-3db8-45b1-888e-d3d9e405ccaf", "name": "p1rlv826", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "85ea6224-1682-4dce-aec8-40cb358842c6"}}}}, {"uuid": "50db1ac5-4754-41e4-9d37-bda897dc343b", "name": "", "x": 38.701232962213865, "y": -122.37378034278039, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "467753c6-5c1f-4a9d-8a7d-21419b25565f", "name": "p1rdm866", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "50db1ac5-4754-41e4-9d37-bda897dc343b"}}}}, {"uuid": "dedcff52-3cd3-467f-9c45-71a2c3e1ba7b", "name": "", "x": 38.70131313984175, "y": -122.37360714205926, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9dcb86a4-e6d7-48b4-b5c2-904635de271b", "name": "p1rlv808", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dedcff52-3cd3-467f-9c45-71a2c3e1ba7b"}}}}, {"uuid": "38d6ab03-3e7f-4fd9-883e-cfa2538e6a9f", "name": "", "x": 38.69441071978218, "y": -122.3742383194926, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f026a1d3-23b0-4454-a09b-e1c08cc06392", "name": "p1rdt472lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "38d6ab03-3e7f-4fd9-883e-cfa2538e6a9f"}}}}, {"uuid": "13e8ba29-89b7-4d05-a57a-3f34b24cc43e", "name": "", "x": 38.69453022804182, "y": -122.37414926221291, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6b4834dc-6bdf-4102-bc13-589392b2e75a", "name": "p1rlv866", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "13e8ba29-89b7-4d05-a57a-3f34b24cc43e"}}}}, {"uuid": "f2a7e3eb-ae43-49d8-b76c-8971895da950", "name": "", "x": 38.69435012529591, "y": -122.37417382958121, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f0ca3ea5-ad01-4e52-883a-c07805f613dd", "name": "p1rdm868", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f2a7e3eb-ae43-49d8-b76c-8971895da950"}}}}, {"uuid": "2576f1fb-b6fb-4af7-8366-e83fc7c59d2f", "name": "", "x": 38.69438573967901, "y": -122.37409302632886, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "26fea867-af5f-4213-b9c3-487975d1285e", "name": "p1rlv812", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2576f1fb-b6fb-4af7-8366-e83fc7c59d2f"}}}}, {"uuid": "7cbb35e7-df97-4165-aed4-3095857f8894", "name": "", "x": 38.69659862303915, "y": -122.37433121095306, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0aa0c31f-baa3-4db8-87d9-0a4ab9a83a8a", "name": "p1rdm870", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7cbb35e7-df97-4165-aed4-3095857f8894"}}}}, {"uuid": "c2ef7e3c-d290-41bb-8503-30c839028bfd", "name": "", "x": 38.69661091258349, "y": -122.37395864008647, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "10d44b60-55c0-4d78-abbb-52c8cd67134b", "name": "p1rlv813", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c2ef7e3c-d290-41bb-8503-30c839028bfd"}}}}, {"uuid": "a0e9fbf2-0b6f-4d7f-8873-daa40e499cae", "name": "", "x": 38.696471493549275, "y": -122.3743203106189, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1f435ec5-8c03-45ba-925b-83bad9501047", "name": "p1rdt473lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a0e9fbf2-0b6f-4d7f-8873-daa40e499cae"}}}}, {"uuid": "a099f1a8-ca54-48a4-85f5-70fbea769a79", "name": "", "x": 38.69629742532447, "y": -122.37431785096992, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "67c560cc-d815-41d4-8087-b66beaacb404", "name": "p1rdm871", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a099f1a8-ca54-48a4-85f5-70fbea769a79"}}}}, {"uuid": "d682dfc2-070f-47a5-a193-156d255f04d9", "name": "", "x": 38.6963229822717, "y": -122.37404164512883, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dd8c54fd-14d4-46fa-8bef-59c1097d5026", "name": "p1rlv818", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d682dfc2-070f-47a5-a193-156d255f04d9"}}}}, {"uuid": "d100526f-6d59-48eb-8c30-a2e68b037935", "name": "", "x": 38.695202937157, "y": -122.37577229914999, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "839858f4-3b18-40c3-86f3-e27225e6aba4", "name": "p1rdt474lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d100526f-6d59-48eb-8c30-a2e68b037935"}}}}, {"uuid": "cc9ae46b-eb99-4a30-b30b-6b6e84f4c59e", "name": "", "x": 38.695250110678316, "y": -122.37563787569754, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b8065f3-8286-4f99-aa56-b9b631a2f838", "name": "p1rlv814", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc9ae46b-eb99-4a30-b30b-6b6e84f4c59e"}}}}, {"uuid": "39fb4e3a-9f26-4cfc-9385-c44381ad05b3", "name": "", "x": 38.69519831370313, "y": -122.37606379343438, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1c89db91-40fe-4de6-973e-5d8c23e35080", "name": "p1rlv827", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "39fb4e3a-9f26-4cfc-9385-c44381ad05b3"}}}}, {"uuid": "9c3d2d3a-8524-4e4a-a0b2-c952bd788674", "name": "", "x": 38.69669246979562, "y": -122.37572883039154, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0ec705b7-fdaa-4eca-96eb-5dabb8256c78", "name": "p1rdm874", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9c3d2d3a-8524-4e4a-a0b2-c952bd788674"}}}}, {"uuid": "9eb67d1a-af44-45e3-8bdb-c4ad6a6e4c48", "name": "", "x": 38.696700867165035, "y": -122.37561376379026, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0d6de7c2-fd2c-4071-8e90-1513f521cf87", "name": "p1rlv816", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9eb67d1a-af44-45e3-8bdb-c4ad6a6e4c48"}}}}, {"uuid": "f6f806f4-f6c8-4acc-b5d4-dc9e58c721ea", "name": "", "x": 38.69688462197356, "y": -122.37574263565365, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1be3e20a-3890-4e9c-b568-ca99421e751c", "name": "p1rdt475lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f6f806f4-f6c8-4acc-b5d4-dc9e58c721ea"}}}}, {"uuid": "41f402a8-5a0d-43bb-92ca-31ba1dcfa4df", "name": "", "x": 38.69722432005433, "y": -122.37575870547994, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c17541ac-d30f-4f0a-9660-f9b9f7012b3a", "name": "p1rdm875", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "41f402a8-5a0d-43bb-92ca-31ba1dcfa4df"}}}}, {"uuid": "3d63d01d-b418-490e-98e2-bd17b4c6be29", "name": "", "x": 38.697222293760795, "y": -122.37537924143979, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d437c83c-cbd1-41bf-b455-21123e82d59f", "name": "p1rlv834", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3d63d01d-b418-490e-98e2-bd17b4c6be29"}}}}, {"uuid": "67a0c060-3859-4b1c-be3d-76b775d3991e", "name": "", "x": 38.70013424053621, "y": -122.37444144316905, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2ffde8c6-9dba-4f13-bda5-a0edf17c736d", "name": "p1rdt476lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "67a0c060-3859-4b1c-be3d-76b775d3991e"}}}}, {"uuid": "ced3b102-df6d-43e6-b894-4e4cf7a0fc03", "name": "", "x": 38.700172278057, "y": -122.37428408934844, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "12556ab7-c50a-4624-9d84-b85585822245", "name": "p1rlv836", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ced3b102-df6d-43e6-b894-4e4cf7a0fc03"}}}}, {"uuid": "6a4ba861-04bc-46c0-9877-3f78ef3e6dcc", "name": "", "x": 38.700326331213084, "y": -122.37444374611572, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f83e2ade-1911-4124-9fbe-6f482d68eba9", "name": "p1rdm878", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a4ba861-04bc-46c0-9877-3f78ef3e6dcc"}}}}, {"uuid": "650858b8-9d22-4882-8e53-a5090bc3e20b", "name": "", "x": 38.700363298980754, "y": -122.37461592326322, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e8f304a4-6e39-4288-9b9b-e41bb37c6019", "name": "p1rlv842", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "650858b8-9d22-4882-8e53-a5090bc3e20b"}}}}, {"uuid": "69c25aa2-cce5-47a1-bd11-f511d4e7ef98", "name": "", "x": 38.69999291375323, "y": -122.3744466507155, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "260b560c-e6d6-4069-b67f-067c468a7768", "name": "p1rdm879", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "69c25aa2-cce5-47a1-bd11-f511d4e7ef98"}}}}, {"uuid": "0b280d8d-3c4c-40e9-9412-11a35d68ccb0", "name": "", "x": 38.699967724899935, "y": -122.37479186664717, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "009758e3-b4ae-427a-9c30-f2a8bb2953d1", "name": "p1rlv868", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0b280d8d-3c4c-40e9-9412-11a35d68ccb0"}}}}, {"uuid": "74720137-2719-4bda-bd40-f1e0e83c7549", "name": "", "x": 38.69983071065769, "y": -122.37444806374667, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e5331a4f-ab91-4fea-a301-11b7afb6c8ca", "name": "p1rdm876", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "74720137-2719-4bda-bd40-f1e0e83c7549"}}}}, {"uuid": "4acdc884-dafb-47f0-9aef-0750c98c89a2", "name": "", "x": 38.69982305246386, "y": -122.37470112738258, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "41e1e576-4cc9-4fea-9d87-d436f000a675", "name": "p1rlv820", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4acdc884-dafb-47f0-9aef-0750c98c89a2"}}}}, {"uuid": "be4b1091-7833-463e-9423-9a59a5df48db", "name": "", "x": 38.70067167519556, "y": -122.37445621396152, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7c94703b-303a-4713-95c0-b2933fe0e70b", "name": "p1rdt477lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be4b1091-7833-463e-9423-9a59a5df48db"}}}}, {"uuid": "45c28223-7f02-491e-a73b-3b9744100bd2", "name": "", "x": 38.700632038038435, "y": -122.37431458299233, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5578d8b4-7c1e-444f-8d27-8c9bf733f420", "name": "p1rlv821", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "45c28223-7f02-491e-a73b-3b9744100bd2"}}}}, {"uuid": "ffdcebf1-e780-4f8b-91bb-fc038927b448", "name": "", "x": 38.700597838321514, "y": -122.37465988051781, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "08c3f5ef-c2d5-4ce2-8fc7-b665d8cbbab6", "name": "p1rlv828", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ffdcebf1-e780-4f8b-91bb-fc038927b448"}}}}, {"uuid": "f5cc1ded-e0f7-495c-ae2c-fbbe9b223fcf", "name": "", "x": 38.69822971347937, "y": -122.37575041780734, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c93c776d-68b8-4e4e-8e5e-d5e34003473c", "name": "p1rdt478lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5cc1ded-e0f7-495c-ae2c-fbbe9b223fcf"}}}}, {"uuid": "3f010d14-4b1e-42be-b585-e0ced44c54ea", "name": "", "x": 38.69822653688614, "y": -122.37611798096295, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "20ce76b6-9305-4525-b77e-b7300edc2c81", "name": "p1rlv824", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3f010d14-4b1e-42be-b585-e0ced44c54ea"}}}}, {"uuid": "ee288a4b-1410-407e-bb84-038feb7a9f5a", "name": "", "x": 38.70127438508099, "y": -122.37425546173934, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8037b713-d948-43c9-8370-fb8fcf6dec15", "name": "p1rdt479lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ee288a4b-1410-407e-bb84-038feb7a9f5a"}}}}, {"uuid": "eb04d832-c5da-4476-b767-3f3132f84fd6", "name": "", "x": 38.701326152810886, "y": -122.3743545350747, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "10373c0d-6a3c-4160-a174-22de447d4c38", "name": "p1rlv832", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eb04d832-c5da-4476-b767-3f3132f84fd6"}}}}, {"uuid": "8a561549-d427-4eb0-aff8-0cac6f22dd4a", "name": "", "x": 38.69561552385404, "y": -122.3739765254889, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "423402f9-4160-481b-9951-a955f8314075", "name": "p1rdt480lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8a561549-d427-4eb0-aff8-0cac6f22dd4a"}}}}, {"uuid": "58cd95d9-c795-4a7d-bf6a-852a7830e1c7", "name": "", "x": 38.69578897651805, "y": -122.37360932935272, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3bc35476-5839-4095-bea5-36e32450b890", "name": "p1rlv835", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "58cd95d9-c795-4a7d-bf6a-852a7830e1c7"}}}}, {"uuid": "1e7206f1-15d5-4231-864e-462f41dde77f", "name": "", "x": 38.69655114284914, "y": -122.37573403506332, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1761b021-00e0-4880-9f05-62cf67aef0e6", "name": "p1rdt481lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1e7206f1-15d5-4231-864e-462f41dde77f"}}}}, {"uuid": "cf2f06ed-eba1-449a-9286-5b45dc3920ec", "name": "", "x": 38.69650464427591, "y": -122.37599494765684, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4eb6c1b4-f09a-44a5-a13f-64051183736d", "name": "p1rlv841", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cf2f06ed-eba1-449a-9286-5b45dc3920ec"}}}}, {"uuid": "ea3ccfaa-4380-4f10-a9e3-de4b5e7d3502", "name": "", "x": 38.70357693514638, "y": -122.37510942987323, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c445ea76-5167-4d55-b0c5-cc53dadc5b5e", "name": "p1rdt482lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea3ccfaa-4380-4f10-a9e3-de4b5e7d3502"}}}}, {"uuid": "d417a786-cd49-46fd-ae63-d886ea429ad5", "name": "", "x": 38.70335811800441, "y": -122.37516485990416, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "26294827-db76-40b6-b652-1e41efdf15dc", "name": "p1rlv844", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d417a786-cd49-46fd-ae63-d886ea429ad5"}}}}, {"uuid": "0dab527d-342b-4f34-87fb-05ef650c3c36", "name": "", "x": 38.70345472163367, "y": -122.37469250108072, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3929a951-8b8b-42e9-a839-40c29e680108", "name": "p1rdm887", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0dab527d-342b-4f34-87fb-05ef650c3c36"}}}}, {"uuid": "d45f0194-8734-4ee3-9e7f-98f34d433fb6", "name": "", "x": 38.703250684927625, "y": -122.37476725706298, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "145d3757-ca09-45ca-9199-465b6b43fbb7", "name": "p1rlv846", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d45f0194-8734-4ee3-9e7f-98f34d433fb6"}}}}, {"uuid": "66e67166-f14a-476d-8648-058991b142e5", "name": "", "x": 38.70365739465258, "y": -122.37551877012066, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0318cdac-5c7b-4711-a0d7-9c7e104c8281", "name": "p1rdm888", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "66e67166-f14a-476d-8648-058991b142e5"}}}}, {"uuid": "a3ae50f4-d19a-4bfa-8ff0-1f84947d8884", "name": "", "x": 38.70348320380497, "y": -122.3754933077317, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e484d77-29ac-4903-afa3-f677283db883", "name": "p1rlv848", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a3ae50f4-d19a-4bfa-8ff0-1f84947d8884"}}}}, {"uuid": "dd460952-fe9a-4bfb-adf2-3abd1eaf4da5", "name": "", "x": 38.702921323422025, "y": -122.3755291486841, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "475b6a50-9814-4016-bb88-be5b1b2ac31d", "name": "p1rdt483lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dd460952-fe9a-4bfb-adf2-3abd1eaf4da5"}}}}, {"uuid": "b23389d5-db2a-42ee-8d67-2310f4899dc8", "name": "", "x": 38.703007845457876, "y": -122.37538641519177, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b053d449-b15b-4292-9a73-9b7d104a8e38", "name": "p1rlv845", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b23389d5-db2a-42ee-8d67-2310f4899dc8"}}}}, {"uuid": "240ea3e2-73c5-4635-bc37-fc108951680c", "name": "", "x": 38.70304524173173, "y": -122.37563909815356, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48b5535c-f00d-4b48-a23a-87f3f212302f", "name": "p1rlv851", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "240ea3e2-73c5-4635-bc37-fc108951680c"}}}}, {"uuid": "82a21e9b-7754-4024-88a0-ae654168e5df", "name": "", "x": 38.702817687028535, "y": -122.37521556434297, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5ea0f4f5-2024-45a8-9f8f-f5963e7d2727", "name": "p1rlv859", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "82a21e9b-7754-4024-88a0-ae654168e5df"}}}}, {"uuid": "669a2a11-e7f7-4f0e-b8c2-68e80fbec40b", "name": "", "x": 38.70279292587802, "y": -122.37564129224644, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "18ea7daf-9665-4d68-b255-12d41bdb2396", "name": "p1rdm892", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "669a2a11-e7f7-4f0e-b8c2-68e80fbec40b"}}}}, {"uuid": "5dc4e885-9a73-4f8e-b1ae-d50867b07dbb", "name": "", "x": 38.70291988195477, "y": -122.37578969289967, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "10611e08-75e2-4422-ac0f-cfb98c7eae4b", "name": "p1rlv855", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5dc4e885-9a73-4f8e-b1ae-d50867b07dbb"}}}}, {"uuid": "d4b2664f-dc7b-4cdb-b3b2-d960e5421cac", "name": "", "x": 38.70292245928232, "y": -122.37627268549726, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0398ef91-eeb8-4d34-b05e-e88adabdd487", "name": "p1rdm890", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d4b2664f-dc7b-4cdb-b3b2-d960e5421cac"}}}}, {"uuid": "2b9bff87-4eb3-4876-9012-61e1b232fe89", "name": "", "x": 38.703110285036146, "y": -122.37600654493566, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a95877ca-8600-4e95-82ac-c51cb82acf16", "name": "p1rlv849", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2b9bff87-4eb3-4876-9012-61e1b232fe89"}}}}, {"uuid": "9251def0-f2e1-4f6e-941b-d92daf95dca5", "name": "", "x": 38.703228109041184, "y": -122.37391642365674, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f396745a-5edb-4ab8-8bc7-2b181719cbf4", "name": "p1rdt484lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9251def0-f2e1-4f6e-941b-d92daf95dca5"}}}}, {"uuid": "49e501ea-9bde-4e92-adc9-d234bbe0089e", "name": "", "x": 38.703036634136346, "y": -122.3740291205105, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "283142ff-4884-4adc-9d4c-f8615505415a", "name": "p1rlv847", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "49e501ea-9bde-4e92-adc9-d234bbe0089e"}}}}, {"uuid": "fa8c24ff-8763-42d3-8d11-c9086c1ba728", "name": "", "x": 38.70327135825731, "y": -122.37410757698957, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e96e4c25-4664-45ae-b77c-9e0047f65c8b", "name": "p1rdm895", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa8c24ff-8763-42d3-8d11-c9086c1ba728"}}}}, {"uuid": "d321aa56-ea46-4547-b406-d12d6edaf433", "name": "", "x": 38.70311835119867, "y": -122.37414341195237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25f84b28-695b-4d32-b96c-914226444b9f", "name": "p1rlv856", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d321aa56-ea46-4547-b406-d12d6edaf433"}}}}, {"uuid": "7db6af4b-6a64-498f-a521-1854f01504d8", "name": "", "x": 38.703669352612835, "y": -122.37607068899858, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60637f4b-8538-4b21-988c-1b13adecc647", "name": "p1rdm896", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7db6af4b-6a64-498f-a521-1854f01504d8"}}}}, {"uuid": "b3c65356-acf8-47e2-8334-90564c73b6ca", "name": "", "x": 38.70391277989249, "y": -122.3760915746208, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f8d49057-9c70-4489-95bb-36b5b574e13d", "name": "p1rlv850", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b3c65356-acf8-47e2-8334-90564c73b6ca"}}}}, {"uuid": "e8a3be83-b908-4eb8-b9a2-4785c43e8598", "name": "", "x": 38.70359885298128, "y": -122.37627393150467, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "da38ec0a-f37d-4a5c-8da0-93410a8fb475", "name": "p1rdt485lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e8a3be83-b908-4eb8-b9a2-4785c43e8598"}}}}, {"uuid": "650cf4f4-5e7c-4f74-b727-66f7380cd60a", "name": "", "x": 38.703581080158116, "y": -122.37641646997498, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3464daa0-06b2-4d5d-9901-bb34050fe619", "name": "p1rdm897", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "650cf4f4-5e7c-4f74-b727-66f7380cd60a"}}}}, {"uuid": "42113e48-8448-48b0-9eb0-8fcced6b8af6", "name": "", "x": 38.703436102309, "y": -122.37626822341811, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "365eff25-8ccb-448b-894f-ad662fe6d684", "name": "p1rlv853", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "42113e48-8448-48b0-9eb0-8fcced6b8af6"}}}}, {"uuid": "05bc81c2-2d04-4cf3-a9a5-7f23fd30a9e3", "name": "", "x": 38.703390597071916, "y": -122.37449755221637, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9d9b6dee-73e1-43ab-ac9b-7d20fb77b6df", "name": "p1rdm898", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "05bc81c2-2d04-4cf3-a9a5-7f23fd30a9e3"}}}}, {"uuid": "7e983a28-7cb7-4af9-b2ce-4ffd390611f0", "name": "", "x": 38.70324715473682, "y": -122.37463680676714, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32142941-c546-4356-ba80-123b9128b5de", "name": "p1rlv852", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7e983a28-7cb7-4af9-b2ce-4ffd390611f0"}}}}, {"uuid": "897928d1-20b8-4749-8364-0b0632b5ca5a", "name": "", "x": 38.70348000850968, "y": -122.37489531232455, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5401d366-a5a2-4753-82b7-ce4fa08a1227", "name": "p1rdt486lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "897928d1-20b8-4749-8364-0b0632b5ca5a"}}}}, {"uuid": "4d064814-1c38-4d96-9a35-d3efdb32c61b", "name": "", "x": 38.70361123258167, "y": -122.37531216321483, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e5e11ab-e042-4038-85c4-162521871722", "name": "p1rdm899", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d064814-1c38-4d96-9a35-d3efdb32c61b"}}}}, {"uuid": "8ee66b9b-0ed0-4790-a55e-d4442e53b1b7", "name": "", "x": 38.703799916455935, "y": -122.3752070170666, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a28cc17a-125d-4b7b-a697-230e3f8853b5", "name": "p1rlv857", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8ee66b9b-0ed0-4790-a55e-d4442e53b1b7"}}}}, {"uuid": "738b4b76-6e5f-44ae-a070-587d3e0c8e90", "name": "", "x": 38.70291683599943, "y": -122.37353789637632, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "47fbd02f-6c12-4bd6-9d6d-2e0cddbfcd88", "name": "p1rdt487lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "738b4b76-6e5f-44ae-a070-587d3e0c8e90"}}}}, {"uuid": "db92746b-b776-4bb9-bdff-ba0791a8c89d", "name": "", "x": 38.702960786540345, "y": -122.373328259674, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2461b6f0-9a40-4b6f-9669-be479da039f3", "name": "p1rlv854", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "db92746b-b776-4bb9-bdff-ba0791a8c89d"}}}}, {"uuid": "eafb6508-d461-4b86-9216-758ab0e8ab85", "name": "", "x": 38.699795636236686, "y": -122.375786328938, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e517b810-e6b9-4c89-b47d-1921fcf88edc", "name": "p1rdt488lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eafb6508-d461-4b86-9216-758ab0e8ab85"}}}}, {"uuid": "b72997ac-862f-46db-a691-047ec1506a3f", "name": "", "x": 38.69977340921936, "y": -122.37552954904456, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "09a7be46-a1bf-459d-836b-beb64324809b", "name": "p1rlv863", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b72997ac-862f-46db-a691-047ec1506a3f"}}}}, {"uuid": "9b4b2a81-aca2-4dfe-b222-4bd3d89f2356", "name": "", "x": 38.699886904548684, "y": -122.37583204363513, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d7f4223-382b-4b9a-9157-baede39de271", "name": "p1rdm901", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9b4b2a81-aca2-4dfe-b222-4bd3d89f2356"}}}}, {"uuid": "d07a2474-09ad-4312-9dd3-89afa4b4b404", "name": "", "x": 38.699878813753116, "y": -122.37554765578757, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6a07d30f-6909-4d74-be8a-1ff8343b4419", "name": "p1rlv861", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d07a2474-09ad-4312-9dd3-89afa4b4b404"}}}}, {"uuid": "65525a66-1773-4ea2-b271-524a8bc99e2f", "name": "", "x": 38.69880247694915, "y": -122.37480953523237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25637062-8ca3-4694-a27b-7be93e89fe1f", "name": "p1rdt489lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65525a66-1773-4ea2-b271-524a8bc99e2f"}}}}, {"uuid": "3d4e34d0-f420-48ce-9811-dd970d236fa2", "name": "", "x": 38.698651585469364, "y": -122.37471132813891, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1fb4003d-498a-494d-89ca-f222d921f63a", "name": "p1rlv869", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3d4e34d0-f420-48ce-9811-dd970d236fa2"}}}}, {"uuid": "b6387c92-387a-45c9-87dc-051d39df6ccd", "name": "", "x": 38.759686999725254, "y": -122.44226913015365, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "601a7504-69fc-4c21-a1d8-1a59751d439c", "name": "p1rdm7860", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b6387c92-387a-45c9-87dc-051d39df6ccd"}}}}, {"uuid": "daba7bcc-f84f-4392-823d-cf77c8291e5e", "name": "", "x": 38.759611722163974, "y": -122.44160216619036, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fd7a84bb-8aa4-4668-9791-a363741823e9", "name": "p1rlv7783", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "daba7bcc-f84f-4392-823d-cf77c8291e5e"}}}}, {"uuid": "f417b4b4-aaed-4be9-aa1d-29ac29530106", "name": "", "x": 38.759987059360896, "y": -122.4422362456647, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8ae14df0-ab3b-47ba-9f83-c09f03999c76", "name": "p1rdt3776lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f417b4b4-aaed-4be9-aa1d-29ac29530106"}}}}, {"uuid": "3d1135bd-0816-4b36-bbc4-3735e50292b3", "name": "", "x": 38.760119212628396, "y": -122.44219670856471, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "391504f7-3b2f-47f0-aadd-47de5c89b16b", "name": "p1rdm7861", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3d1135bd-0816-4b36-bbc4-3735e50292b3"}}}}, {"uuid": "811d2f8e-757f-4164-9b75-2c45d474b794", "name": "", "x": 38.76011816883335, "y": -122.4419780350059, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "24e665a0-3ba6-46a7-bc02-327b6f77c409", "name": "p1rlv7784", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "811d2f8e-757f-4164-9b75-2c45d474b794"}}}}, {"uuid": "08c1e17d-fdf8-42ae-9eb9-e06c74feb269", "name": "", "x": 38.75891156323847, "y": -122.44466513486701, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4662f3f5-e75b-4b75-a6d6-7ada745d5cca", "name": "p1rdt3777lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "08c1e17d-fdf8-42ae-9eb9-e06c74feb269"}}}}, {"uuid": "44fc4fff-3b31-4f55-8b28-afc7b1803074", "name": "", "x": 38.75891004710453, "y": -122.44564742267218, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9af62e3c-9357-4505-a2f6-3b4252dab81b", "name": "p1rlv7786", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "44fc4fff-3b31-4f55-8b28-afc7b1803074"}}}}, {"uuid": "d07200f5-dcef-4fc8-b31d-44f9a58cb3af", "name": "", "x": 38.75892205855218, "y": -122.44438129888907, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "90158ee6-01aa-48ce-867f-8e459e7a5e09", "name": "p1rdm7862", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d07200f5-dcef-4fc8-b31d-44f9a58cb3af"}}}}, {"uuid": "2c94939f-e53a-4390-a61c-2fdeaf2224ef", "name": "", "x": 38.758813649325106, "y": -122.44432459271447, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1571d1a3-a151-4972-8cb1-aeb36b660abc", "name": "p1rlv7785", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2c94939f-e53a-4390-a61c-2fdeaf2224ef"}}}}, {"uuid": "2abed101-61b0-40f8-9656-14aa9bb44653", "name": "", "x": 38.665452782208654, "y": -122.46042242219686, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e734d7a2-9161-41c0-ba78-9f9f87120acd", "name": "p1rdt5098lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2abed101-61b0-40f8-9656-14aa9bb44653"}}}}, {"uuid": "349e93eb-bbeb-4cf6-962a-1da6b3e846fb", "name": "", "x": 38.66549109565642, "y": -122.46029967067366, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "09926231-b077-4aa6-afd8-acf89744865a", "name": "p1rlv10453", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "349e93eb-bbeb-4cf6-962a-1da6b3e846fb"}}}}, {"uuid": "ec821adf-cbe4-4f10-99c3-85668031f401", "name": "", "x": 38.665383753359855, "y": -122.46047289225729, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9a639e8d-ac8c-46e8-a4b5-6c551612b209", "name": "p1rlv10468", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ec821adf-cbe4-4f10-99c3-85668031f401"}}}}, {"uuid": "7096e027-1f66-45c2-8594-9b2f6171bb76", "name": "", "x": 38.665480227274244, "y": -122.45989744815324, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d40fc87f-1b73-4ed4-a397-dbc94312dcad", "name": "p1rlv10482", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7096e027-1f66-45c2-8594-9b2f6171bb76"}}}}, {"uuid": "1761a6d4-5d26-409e-b522-e6548258829b", "name": "", "x": 38.665521469030836, "y": -122.46102359049253, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "efd01236-6ba3-424e-829b-3f3950ce6265", "name": "p1rlv10517", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1761a6d4-5d26-409e-b522-e6548258829b"}}}}, {"uuid": "9dc653ac-d7a4-4f89-a699-b360eff11ffe", "name": "", "x": 38.65349301133138, "y": -122.48412729471077, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "91754be7-2a91-4a0e-9856-43d08ecc7c70", "name": "p1rdt5548lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9dc653ac-d7a4-4f89-a699-b360eff11ffe"}}}}, {"uuid": "32548a03-8760-4329-b730-0eb4180d6402", "name": "", "x": 38.65285475188867, "y": -122.48386195652688, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "773a6b9e-d708-4f7c-a901-9406bcc3dcde", "name": "p1rlv11503", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "32548a03-8760-4329-b730-0eb4180d6402"}}}}, {"uuid": "6daffc64-545f-48b6-b9dd-c01a7caf0cd9", "name": "", "x": 38.65294527277444, "y": -122.48395324626152, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f7efbb32-55d4-409b-a37f-bf01d0620d40", "name": "p1rlv19645", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6daffc64-545f-48b6-b9dd-c01a7caf0cd9"}}}}, {"uuid": "d52b4ce6-a2a9-4d89-b20c-badbd780ff8b", "name": "", "x": 38.65351451941317, "y": -122.48429393725958, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c4c77c78-e261-4d17-93ff-caad4d86246b", "name": "p1rdm11706", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d52b4ce6-a2a9-4d89-b20c-badbd780ff8b"}}}}, {"uuid": "5c8ae331-4dc1-4b73-8eb7-19d3d44f688f", "name": "", "x": 38.65313573125618, "y": -122.48422769840043, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9e90f763-682e-4771-976c-9cd736b72133", "name": "p1rlv19640", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5c8ae331-4dc1-4b73-8eb7-19d3d44f688f"}}}}, {"uuid": "e12efe67-ffe9-45e6-8d49-c58f292ff6e8", "name": "", "x": 38.65401139999537, "y": -122.48253201007375, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "15ae4af0-db43-4f1b-bd8c-c6be31d034aa", "name": "p1rdm11719", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e12efe67-ffe9-45e6-8d49-c58f292ff6e8"}}}}, {"uuid": "3ba0dc35-2b37-4a80-ade1-eac0f9902e85", "name": "", "x": 38.65384898920333, "y": -122.48248720829615, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "84b9d44e-2c8d-4cee-a9d2-327a41ab8dad", "name": "p1rlv11513", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3ba0dc35-2b37-4a80-ade1-eac0f9902e85"}}}}, {"uuid": "0bf7988f-5ebc-458b-826c-ec6efad5e132", "name": "", "x": 38.65406486613757, "y": -122.48238206755065, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "05b867e6-2f18-49e7-9869-55bd5048c201", "name": "p1rdt5557lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0bf7988f-5ebc-458b-826c-ec6efad5e132"}}}}, {"uuid": "dcf43b02-4298-41d4-ad1c-92d87578993e", "name": "", "x": 38.654054728485086, "y": -122.4821409504333, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "effa94d0-34ae-4cbe-b8da-fd1693d47b3a", "name": "p1rdm11720", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dcf43b02-4298-41d4-ad1c-92d87578993e"}}}}, {"uuid": "4931ad26-9e32-4cb4-85cd-f7485acc5477", "name": "", "x": 38.65329740432264, "y": -122.48206595565533, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bf457d88-958c-446a-9584-73be8c609bbe", "name": "p1rlv19574", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4931ad26-9e32-4cb4-85cd-f7485acc5477"}}}}, {"uuid": "f173e132-e022-46a1-b3cf-6fb8b348146f", "name": "", "x": 38.655212268996365, "y": -122.4810200626239, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d5838960-8556-4e4a-95e9-8ba9ffc85141", "name": "p1rdt5560lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f173e132-e022-46a1-b3cf-6fb8b348146f"}}}}, {"uuid": "edd6a9c5-95e0-4cbc-9328-cd8be4f904c6", "name": "", "x": 38.655330800417374, "y": -122.48132726741721, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "86d82a1e-1596-4fb3-9f3d-44c9553396d2", "name": "p1rlv11516", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "edd6a9c5-95e0-4cbc-9328-cd8be4f904c6"}}}}, {"uuid": "3fcef969-b8f3-49c8-ad03-1838c6eac971", "name": "", "x": 38.65375449158675, "y": -122.48352206240394, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "133a0221-0cd5-46d2-af84-e80e7951c96d", "name": "p1rdt5561lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3fcef969-b8f3-49c8-ad03-1838c6eac971"}}}}, {"uuid": "5a41b4bf-e666-4b1b-834e-521504b72b04", "name": "", "x": 38.65442296031636, "y": -122.48389667390005, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "179d1d84-0dfe-4920-a039-009f33bc1d8d", "name": "p1rlv11517", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5a41b4bf-e666-4b1b-834e-521504b72b04"}}}}, {"uuid": "2f613491-2ee1-4f3f-9d9a-e20f2d3640a5", "name": "", "x": 38.65445021577995, "y": -122.48126863552662, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8deb73b9-51fc-447d-9da7-14a6dccff646", "name": "p1rdt5564lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2f613491-2ee1-4f3f-9d9a-e20f2d3640a5"}}}}, {"uuid": "5397d76e-8423-4b26-b76a-ed3deff45a7c", "name": "", "x": 38.65452001830409, "y": -122.48139057750333, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f8f0f8a2-f528-45bd-8fbd-22f6699fe7e0", "name": "p1rlv11521", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5397d76e-8423-4b26-b76a-ed3deff45a7c"}}}}, {"uuid": "d1eb9046-a524-4a94-b3ce-001d80998cd8", "name": "", "x": 38.653503595754145, "y": -122.48459005947156, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "95a5450a-6630-41b8-863f-0c1f3fcfa7ab", "name": "p1rdt5566lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1eb9046-a524-4a94-b3ce-001d80998cd8"}}}}, {"uuid": "c57fc713-783d-4b5e-a8bc-8461f19caa7a", "name": "", "x": 38.652722315413676, "y": -122.48448349500988, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "69eba934-3f80-4abc-b5e8-9cdc79aa05a3", "name": "p1rlv11523", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c57fc713-783d-4b5e-a8bc-8461f19caa7a"}}}}, {"uuid": "bb4f6529-f339-4286-bf82-44fc21a9adef", "name": "", "x": 38.65290868561374, "y": -122.48312227902461, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "613d178b-a566-408d-bad0-e4a170eea971", "name": "p1rdt5568lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bb4f6529-f339-4286-bf82-44fc21a9adef"}}}}, {"uuid": "317c2a79-f30d-438a-93a0-556de85f2806", "name": "", "x": 38.65290346928153, "y": -122.48306882713341, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b97ebb0-09a4-4c42-a10e-e3aff344aa44", "name": "p1rlv11526", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "317c2a79-f30d-438a-93a0-556de85f2806"}}}}, {"uuid": "aff86a89-8b6f-444c-a1a3-218129998f5b", "name": "", "x": 38.6535709305957, "y": -122.48453866803233, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0460a67f-dcc1-4829-99f8-7a0b6a8cedbc", "name": "p1rdm11742", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aff86a89-8b6f-444c-a1a3-218129998f5b"}}}}, {"uuid": "3e312389-c9f7-417a-be1e-7d41819eff67", "name": "", "x": 38.652965879895014, "y": -122.48453921146539, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "21b18539-fba6-4b52-b8bf-38c2a6c4abfb", "name": "p1rlv11533", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e312389-c9f7-417a-be1e-7d41819eff67"}}}}, {"uuid": "f3df1aff-a25f-42fd-82d9-c0e51c70bc8f", "name": "", "x": 38.65330877367878, "y": -122.48464018641775, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8f0e181a-fa89-4c5d-a1cb-6080f91331da", "name": "p1rlv19643", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f3df1aff-a25f-42fd-82d9-c0e51c70bc8f"}}}}, {"uuid": "6e5af62d-2fbe-4dfd-b7d1-8a1040a5ab7e", "name": "", "x": 38.65345372369736, "y": -122.48479084547154, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "248e065d-80ed-4926-9625-295c83da6b61", "name": "p1rdt5574lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6e5af62d-2fbe-4dfd-b7d1-8a1040a5ab7e"}}}}, {"uuid": "981c76fc-50f5-4e40-ae36-c33893f91beb", "name": "", "x": 38.65346288080924, "y": -122.48484594711942, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6554d73d-5cf7-4531-a524-78e70b36fd8d", "name": "p1rdm11743", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "981c76fc-50f5-4e40-ae36-c33893f91beb"}}}}, {"uuid": "365c2b7e-424c-4246-8ec1-4d1f39dbbcbb", "name": "", "x": 38.65324635107003, "y": -122.48479003561559, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "813f887e-6807-4ffc-90bf-bd30cde9a9df", "name": "p1rlv19610", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "365c2b7e-424c-4246-8ec1-4d1f39dbbcbb"}}}}, {"uuid": "e1ac22f0-6134-44d1-8d4f-f2948df6203a", "name": "", "x": 38.65211076864418, "y": -122.48360342410952, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "21ef4ae6-b80e-49f1-8d00-1cb6e27bc8f9", "name": "p1rdt5577lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e1ac22f0-6134-44d1-8d4f-f2948df6203a"}}}}, {"uuid": "c8697d6c-15d8-4c61-a6de-4f056fdb7afb", "name": "", "x": 38.65211742852992, "y": -122.48423500000004, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1148946c-8c37-4482-afce-5082cd2b7ad4", "name": "p1rdt5577lv-p1rlv11540x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c8697d6c-15d8-4c61-a6de-4f056fdb7afb"}}}}, {"uuid": "53948b43-71df-47cc-80ba-c157d05bf7d7", "name": "", "x": 38.65207242155051, "y": -122.48424681497777, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f79b14c8-e77d-49c1-9336-e7407ad4c94d", "name": "p1rlv11540", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "53948b43-71df-47cc-80ba-c157d05bf7d7"}}}}, {"uuid": "2a1c2b55-25ee-42cc-8a93-81ebf49aae00", "name": "", "x": 38.65279916105022, "y": -122.4835175838475, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "752bcf04-7a44-42b0-9a46-44c243b78eb5", "name": "p1rdt5577lv-p1rlv19608x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2a1c2b55-25ee-42cc-8a93-81ebf49aae00"}}}}, {"uuid": "bcf33a8f-8984-4542-a3db-d89c5f01df6e", "name": "", "x": 38.652193358258536, "y": -122.48306224209226, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f917b142-d59f-4a51-8c3b-913feb53411d", "name": "p1rlv19608", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bcf33a8f-8984-4542-a3db-d89c5f01df6e"}}}}, {"uuid": "4483501b-cdce-4aa1-833e-1d89f54498eb", "name": "", "x": 38.66703472717699, "y": -122.47875999417263, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a5559c15-cdac-4a4d-a2a0-b99c9befb310", "name": "p1rdm13355", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4483501b-cdce-4aa1-833e-1d89f54498eb"}}}}, {"uuid": "8e65ba3a-d5dc-4516-9dcc-39816f28eb6c", "name": "", "x": 38.666963198566314, "y": -122.47888695389291, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1564c5f9-8b80-41b4-af09-2a55dee0718b", "name": "p1rlv13033", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8e65ba3a-d5dc-4516-9dcc-39816f28eb6c"}}}}, {"uuid": "358567fb-7670-4972-bc4a-8361e82ef171", "name": "", "x": 38.66717310843214, "y": -122.47884342821176, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a9859b30-0238-493e-be1a-cb6717413ba9", "name": "p1rdt6261lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "358567fb-7670-4972-bc4a-8361e82ef171"}}}}, {"uuid": "9605bc5c-3d00-4414-ba84-af1384312959", "name": "", "x": 38.667278908257714, "y": -122.47895363367641, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ba5e6363-0b23-4726-8013-f3d040511005", "name": "p1rdm13356", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9605bc5c-3d00-4414-ba84-af1384312959"}}}}, {"uuid": "d06077af-253f-4440-a72d-e4097453ec3e", "name": "", "x": 38.66717220353242, "y": -122.4792762580999, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "23aae8f1-8b9f-4453-9643-b49ffdc80889", "name": "p1rlv13036", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d06077af-253f-4440-a72d-e4097453ec3e"}}}}, {"uuid": "1edf8d84-7823-4da1-a9cf-7d60fa171495", "name": "", "x": 38.66655673727605, "y": -122.48006632205775, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c2172b57-622b-44c1-8388-f1e2b1def312", "name": "p1rdt6262lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1edf8d84-7823-4da1-a9cf-7d60fa171495"}}}}, {"uuid": "e08f8ab0-1195-4113-aad2-d08a9ef594fb", "name": "", "x": 38.66654421125099, "y": -122.47991300856037, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3b7bff1-90da-4ee2-8a0f-8e291a7e8ac8", "name": "p1rlv13034", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e08f8ab0-1195-4113-aad2-d08a9ef594fb"}}}}, {"uuid": "cc8e6a88-7c99-4b4d-a6a2-b5b5983b91f3", "name": "", "x": 38.66654838989604, "y": -122.48021581199129, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c6839f65-9d3b-4bd6-89a4-0c8feb33e98a", "name": "p1rlv13040", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc8e6a88-7c99-4b4d-a6a2-b5b5983b91f3"}}}}, {"uuid": "ff16a8d5-a522-4782-b3a5-3bae4ab23764", "name": "", "x": 38.66690377458573, "y": -122.48086176489268, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4717b000-fd39-4647-9fbd-5152323dacee", "name": "p1rdt6263lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ff16a8d5-a522-4782-b3a5-3bae4ab23764"}}}}, {"uuid": "1220e772-0453-4a0b-b571-cc0a62841ce9", "name": "", "x": 38.66687779947186, "y": -122.48081912313049, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c6d309ef-b082-4022-a265-4891cdcd6db9", "name": "p1rlv13035", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1220e772-0453-4a0b-b571-cc0a62841ce9"}}}}, {"uuid": "03fd6629-3635-4d50-8480-1e1e39c348ec", "name": "", "x": 38.66255558019544, "y": -122.47741013877915, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e916c16-525d-4092-b627-ad44b4bf4ee8", "name": "p1rdt6264lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "03fd6629-3635-4d50-8480-1e1e39c348ec"}}}}, {"uuid": "5b083b59-faa7-407f-94c6-95a8fb7db4e9", "name": "", "x": 38.66254447908395, "y": -122.47746230770055, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7f5d04aa-74fb-4d1a-ac91-6c01a56a94b5", "name": "p1rlv13037", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5b083b59-faa7-407f-94c6-95a8fb7db4e9"}}}}, {"uuid": "f42abcc6-9394-4f6f-afa6-91874259a980", "name": "", "x": 38.66061026704863, "y": -122.48036217979423, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e6bb5544-e583-4ded-9a10-23be70f5598e", "name": "p1rdt6265lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f42abcc6-9394-4f6f-afa6-91874259a980"}}}}, {"uuid": "c47455e5-7a81-46e7-8b23-13a1b138d9b2", "name": "", "x": 38.660735364357585, "y": -122.48075957945385, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9a8b4502-31fd-4dce-8717-9860880075b4", "name": "p1rlv13038", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c47455e5-7a81-46e7-8b23-13a1b138d9b2"}}}}, {"uuid": "768cb989-5a66-410d-bed8-df0e10c19744", "name": "", "x": 38.660452382345134, "y": -122.47994557664096, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "34d43081-e4a3-4f1b-8b90-5965458452d0", "name": "p1rlv13039", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "768cb989-5a66-410d-bed8-df0e10c19744"}}}}, {"uuid": "c00988a8-164a-4ae9-87ff-eda2c2eb1e48", "name": "", "x": 38.66246119968208, "y": -122.47659512275703, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8af5f9d5-965c-4a0c-a811-67d3bed744ee", "name": "p1rdt6266lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c00988a8-164a-4ae9-87ff-eda2c2eb1e48"}}}}, {"uuid": "c8e8dfff-c156-4d84-b476-8dbf65fb2e45", "name": "", "x": 38.66248671917567, "y": -122.47655203872152, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60144ce1-d4d6-4725-b543-f881894356a5", "name": "p1rlv13041", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c8e8dfff-c156-4d84-b476-8dbf65fb2e45"}}}}, {"uuid": "62fb1dd6-10cf-453b-a9db-bf538e6415e4", "name": "", "x": 38.6652765486321, "y": -122.4794367281912, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d0ddd898-3193-4bff-80f4-fd4a7eae9aec", "name": "p1rdt6267lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "62fb1dd6-10cf-453b-a9db-bf538e6415e4"}}}}, {"uuid": "74b1a318-c73f-40ae-a0e6-13095293a6a8", "name": "", "x": 38.665302069155366, "y": -122.47939364345397, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "296cd07e-c2e3-4031-abad-9c870a65105d", "name": "p1rlv13042", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "74b1a318-c73f-40ae-a0e6-13095293a6a8"}}}}, {"uuid": "f4e4a449-0026-4c8d-b73e-666ad21ff0e4", "name": "", "x": 38.64756555827549, "y": -122.50910380696413, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b1155c2c-544c-45f4-969f-b3ec4f6773bb", "name": "p1rdt6488lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f4e4a449-0026-4c8d-b73e-666ad21ff0e4"}}}}, {"uuid": "941c708e-42ff-43af-9af5-da57099f33ff", "name": "", "x": 38.647565542168486, "y": -122.50904985776398, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3243ca2f-a97e-4fbc-981d-85eded2e5e6b", "name": "p1rlv13513", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "941c708e-42ff-43af-9af5-da57099f33ff"}}}}, {"uuid": "59de6cf1-c8b9-4799-9a3e-2d4543e023f1", "name": "", "x": 38.66460136270918, "y": -122.44791156272083, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "555453a3-3fb7-426a-bbd2-9e588d4bd01d", "name": "p1rdt6578lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59de6cf1-c8b9-4799-9a3e-2d4543e023f1"}}}}, {"uuid": "73222e13-9809-4b5b-b542-81f2e9da8236", "name": "", "x": 38.66482282070209, "y": -122.4484080912382, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b0ca6e47-afec-4d61-885a-e38176b32444", "name": "p1rlv13823", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "73222e13-9809-4b5b-b542-81f2e9da8236"}}}}, {"uuid": "89f1ffe4-82cc-44f4-b229-a1afaf6f6224", "name": "", "x": 38.66450541345186, "y": -122.44798523933892, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b2fe65b3-6fcc-4416-bca4-9a0f6551b801", "name": "p1rdm14192", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "89f1ffe4-82cc-44f4-b229-a1afaf6f6224"}}}}, {"uuid": "3480b5cb-c591-42d2-9162-b0b478d1a56f", "name": "", "x": 38.664643133522475, "y": -122.44852441239391, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "47a7519a-b550-41e6-99e3-c2115db425fe", "name": "p1rlv13789", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3480b5cb-c591-42d2-9162-b0b478d1a56f"}}}}, {"uuid": "05f1416d-d004-448f-b835-8e7320ea9e88", "name": "", "x": 38.664533911991846, "y": -122.4482953651979, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "94ac9254-cdbf-4864-b22b-bcfb0a827700", "name": "p1rlv13796", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "05f1416d-d004-448f-b835-8e7320ea9e88"}}}}, {"uuid": "91603163-b327-419b-a562-9c486068b876", "name": "", "x": 38.66474807177311, "y": -122.44784544493244, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e0be7c1-65b8-4de4-89f2-56b6bf1ea321", "name": "p1rdm14194", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "91603163-b327-419b-a562-9c486068b876"}}}}, {"uuid": "51acf417-9cd8-46f7-97c9-1dcf69d8d859", "name": "", "x": 38.664827245819765, "y": -122.44803626546826, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "028d5ead-7c34-400b-bcc1-c4d706c965d3", "name": "p1rlv13814", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "51acf417-9cd8-46f7-97c9-1dcf69d8d859"}}}}, {"uuid": "99ed1f5c-706f-4524-beb7-df5068132667", "name": "", "x": 38.66661910169782, "y": -122.45155134514903, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5de250a8-ecca-4ab4-9f09-685aaf92d13d", "name": "p1rdt6580lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "99ed1f5c-706f-4524-beb7-df5068132667"}}}}, {"uuid": "c929ea7a-c3b7-4391-8edc-8285bd035f71", "name": "", "x": 38.666738131523914, "y": -122.4513475088475, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "251f270f-4238-4fe6-8ab3-f884fca7a42d", "name": "p1rlv13791", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c929ea7a-c3b7-4391-8edc-8285bd035f71"}}}}, {"uuid": "b64d8094-1b15-4af2-acb7-1e043d25b76f", "name": "", "x": 38.66668551808711, "y": -122.45165826434774, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ab29ca66-d59b-4aa6-b5f6-165add0bc331", "name": "p1rlv13810", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b64d8094-1b15-4af2-acb7-1e043d25b76f"}}}}, {"uuid": "52721818-3941-4aff-9668-b15d64e4bdbd", "name": "", "x": 38.666731383536465, "y": -122.45183033352055, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "99957459-46a6-4b2b-9813-69b11ca7dad1", "name": "p1rlv13815", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "52721818-3941-4aff-9668-b15d64e4bdbd"}}}}, {"uuid": "247043b9-09d5-4c87-b578-344fd897a004", "name": "", "x": 38.66641388074643, "y": -122.4513844669654, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "36c12a74-a2ca-439a-a69f-308dd5cb1207", "name": "p1rlv13819", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "247043b9-09d5-4c87-b578-344fd897a004"}}}}, {"uuid": "ea0e7b78-57d9-4a45-8c88-1895800c3377", "name": "", "x": 38.66518206185532, "y": -122.44754723338062, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4d944119-3782-49dd-8b24-1f68d8ee687c", "name": "p1rdt6584lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea0e7b78-57d9-4a45-8c88-1895800c3377"}}}}, {"uuid": "d1cbf045-63a5-47f4-8bc1-deba3702bf62", "name": "", "x": 38.66553515936385, "y": -122.4484945814938, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e96bcc5b-07c5-4289-aec4-0224395c5e8a", "name": "p1rlv13817", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1cbf045-63a5-47f4-8bc1-deba3702bf62"}}}}, {"uuid": "a2f9db05-7e24-4244-8ad2-e1510b25c7d1", "name": "", "x": 38.664864895136674, "y": -122.44777558197904, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "39af24f1-0fa2-465e-a288-2b620d9e9d59", "name": "p1rdm14215", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a2f9db05-7e24-4244-8ad2-e1510b25c7d1"}}}}, {"uuid": "feda626a-d10e-404b-8da3-429c769d4502", "name": "", "x": 38.66522828205339, "y": -122.4483934862407, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "accec892-a236-462d-b714-1178393ec992", "name": "p1rlv13801", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "feda626a-d10e-404b-8da3-429c769d4502"}}}}, {"uuid": "8c3e1a23-2e50-4e2b-bd42-b64588a6a090", "name": "", "x": 38.66526883647157, "y": -122.44743914288946, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32db643a-7c82-4816-8629-7935cab09567", "name": "p1rdm14218", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8c3e1a23-2e50-4e2b-bd42-b64588a6a090"}}}}, {"uuid": "3993ede8-b98b-4f7e-8582-45a688300ddf", "name": "", "x": 38.66568002523225, "y": -122.4480376675357, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6ade9991-a857-4619-8094-c18f824aaeb9", "name": "p1rlv13822", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3993ede8-b98b-4f7e-8582-45a688300ddf"}}}}, {"uuid": "c957710d-5b59-48d4-a705-163d7bef81c0", "name": "", "x": 38.665376485198, "y": -122.44733486613728, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e81f150f-30cd-4c9a-b5b7-7a633633702d", "name": "p1rdm14216", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c957710d-5b59-48d4-a705-163d7bef81c0"}}}}, {"uuid": "0640235f-69e2-44df-a002-75850f23e028", "name": "", "x": 38.66561322577763, "y": -122.44785029518839, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c26fba44-3b81-47de-81e6-522f2daf0534", "name": "p1rlv13807", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0640235f-69e2-44df-a002-75850f23e028"}}}}, {"uuid": "9a67951a-5d21-4aaf-8cf1-055c0e9b6ed4", "name": "", "x": 38.6660700064695, "y": -122.44833835279438, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9c587698-7940-4edb-9105-f31f1304f7e9", "name": "p1rdt6587lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9a67951a-5d21-4aaf-8cf1-055c0e9b6ed4"}}}}, {"uuid": "94a40471-e692-4c82-9db0-8a67ada7ed7d", "name": "", "x": 38.66604401958438, "y": -122.44829572341504, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1c795ac7-3b49-4158-996d-2fb1f0337847", "name": "p1rlv13808", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "94a40471-e692-4c82-9db0-8a67ada7ed7d"}}}}, {"uuid": "fa34ac6d-08b7-48d7-a2f6-0fb2f91ccd62", "name": "", "x": 38.665782733034895, "y": -122.44688743442987, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "61045f72-ca3d-4e0d-ac3d-db5fbf099b38", "name": "p1rdt6588lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa34ac6d-08b7-48d7-a2f6-0fb2f91ccd62"}}}}, {"uuid": "18f4c8ab-3825-40dd-ae7c-e806892501d8", "name": "", "x": 38.66551610253854, "y": -122.44636826305491, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "687996da-ab03-4544-b0d9-b79b8ac88e95", "name": "p1rlv13809", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "18f4c8ab-3825-40dd-ae7c-e806892501d8"}}}}, {"uuid": "774d8c44-6377-428c-89ae-01326c5972f4", "name": "", "x": 38.66470818578833, "y": -122.44621086682648, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a289017a-8ab9-4412-857a-694b3aa2c63d", "name": "p1rdt6590lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "774d8c44-6377-428c-89ae-01326c5972f4"}}}}, {"uuid": "aca2fbd4-467d-4bf7-8341-2b23f9d30c2b", "name": "", "x": 38.66472254581389, "y": -122.44626167635215, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a2caa70b-9143-4676-834b-bfc7cb41330c", "name": "p1rlv13820", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aca2fbd4-467d-4bf7-8341-2b23f9d30c2b"}}}}, {"uuid": "51a9a4f7-cb5d-4fe5-9213-71fe12585bae", "name": "", "x": 38.66450288065584, "y": -122.44662624081425, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8a7c2e99-857f-4119-be4a-daaca586f056", "name": "p1rdt6591lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "51a9a4f7-cb5d-4fe5-9213-71fe12585bae"}}}}, {"uuid": "bd002735-2c22-4505-9f8a-7fed31956b37", "name": "", "x": 38.664476893151246, "y": -122.44658361298364, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "66e6c732-919a-4851-9f76-5580ea71669d", "name": "p1rlv13821", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bd002735-2c22-4505-9f8a-7fed31956b37"}}}}, {"uuid": "53ce4353-6591-4b16-8c1b-6a572722d9d2", "name": "", "x": 38.650925590961236, "y": -122.47648370205337, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8ad975da-cce7-49cb-be78-20c4abf8975e", "name": "p1rdt7286lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "53ce4353-6591-4b16-8c1b-6a572722d9d2"}}}}, {"uuid": "1f533a6b-7428-41c4-9100-81e5b64c526d", "name": "", "x": 38.65091178622824, "y": -122.47653475192051, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "17bf6d8f-8215-4294-b921-cc3e34476f1e", "name": "p1rlv15585", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1f533a6b-7428-41c4-9100-81e5b64c526d"}}}}, {"uuid": "7bd1bc68-a2a4-45a5-8c9c-3c8b6a13e850", "name": "", "x": 38.650690731688435, "y": -122.47687130836174, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "56d21681-3c57-4575-af17-f2bbf9874a10", "name": "p1rdt7289lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7bd1bc68-a2a4-45a5-8c9c-3c8b6a13e850"}}}}, {"uuid": "ab2a10f9-9b8c-4c25-a988-03a6d071f099", "name": "", "x": 38.6509152754639, "y": -122.47733687713344, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ef2a4478-4644-4bd3-9548-ab1d0be338b5", "name": "p1rlv15590", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ab2a10f9-9b8c-4c25-a988-03a6d071f099"}}}}, {"uuid": "9baa86b9-b0df-4541-ad87-bc928134642d", "name": "", "x": 38.650433450846926, "y": -122.47639803350314, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c04c9ad1-4277-47de-9cec-9ce86e17b4f1", "name": "p1rlv15591", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9baa86b9-b0df-4541-ad87-bc928134642d"}}}}, {"uuid": "c5d952d0-6fca-404d-bafd-c21da4301161", "name": "", "x": 38.64948736383664, "y": -122.47579982496423, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a9b0c16f-f433-4aa1-8d00-dc1573dfb5e3", "name": "p1rdt7293lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c5d952d0-6fca-404d-bafd-c21da4301161"}}}}, {"uuid": "90c36dbe-020f-474a-abb4-c1e99f474701", "name": "", "x": 38.64940610565797, "y": -122.47576594155083, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "629e2259-2a59-4b20-b8bf-7b3b2c4a48f9", "name": "p1rlv15595", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "90c36dbe-020f-474a-abb4-c1e99f474701"}}}}, {"uuid": "cee60e10-1306-4dec-9856-0151cfeda93e", "name": "", "x": 38.64955676013305, "y": -122.47582982129457, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "af6b7d1b-896f-44ac-8038-748c74507253", "name": "p1rlv15598", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cee60e10-1306-4dec-9856-0151cfeda93e"}}}}, {"uuid": "15fe8ec5-07e2-4234-a2a7-51372760b4ae", "name": "", "x": 38.654450185149294, "y": -122.50266398158654, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2c1ea087-8a4d-49ca-af35-b86aed849c98", "name": "p1rdm16003", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "15fe8ec5-07e2-4234-a2a7-51372760b4ae"}}}}, {"uuid": "a779adaf-c56f-4ee1-b671-6b1ebacd5ed8", "name": "", "x": 38.65486320126965, "y": -122.50230485132435, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1ae1bbf1-459f-4346-b525-393b7d1dc958", "name": "p1rlv15599", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a779adaf-c56f-4ee1-b671-6b1ebacd5ed8"}}}}, {"uuid": "6c968024-4d09-403e-8de9-24c501753797", "name": "", "x": 38.65438386391856, "y": -122.5025685251368, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e67d2b31-f05a-4160-83ae-55154224a9ca", "name": "p1rdt7294lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c968024-4d09-403e-8de9-24c501753797"}}}}, {"uuid": "3a8505e3-0148-40ca-8dea-f61cc48f9601", "name": "", "x": 38.65435022729933, "y": -122.50246929784952, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "84040096-aca8-4cee-8539-83ae8f875e98", "name": "p1rdm16004", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3a8505e3-0148-40ca-8dea-f61cc48f9601"}}}}, {"uuid": "1214be7e-500a-4096-ad98-58bc00c5743b", "name": "", "x": 38.65468208995729, "y": -122.50209923605257, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "200aa7d8-0a43-4086-b0e7-f63cae75671d", "name": "p1rlv15618", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1214be7e-500a-4096-ad98-58bc00c5743b"}}}}, {"uuid": "fb368e45-5c62-4a91-958e-6df0c1eec86a", "name": "", "x": 38.653703111752435, "y": -122.50076138596326, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "381018f1-11cd-4519-ad24-d3419116ea84", "name": "p1rdm16011", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fb368e45-5c62-4a91-958e-6df0c1eec86a"}}}}, {"uuid": "eb97ab60-a0ad-46ff-81c6-1ab952ef9d01", "name": "", "x": 38.653216389940184, "y": -122.5007417792492, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "95b45d46-b7e7-46e2-98d9-5034e2fa0a17", "name": "p1rlv15604", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eb97ab60-a0ad-46ff-81c6-1ab952ef9d01"}}}}, {"uuid": "6432a19e-5501-4437-a6b0-cd8612d69898", "name": "", "x": 38.65369179013314, "y": -122.5008839086118, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4cee417a-3410-4907-8621-f0d3fcbc047c", "name": "p1rdt7299lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6432a19e-5501-4437-a6b0-cd8612d69898"}}}}, {"uuid": "799f4d77-24d9-4527-bf0a-c0834026128f", "name": "", "x": 38.653722262619546, "y": -122.50102558146277, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60d0a9cf-54f3-4049-9957-29839b7beb08", "name": "p1rdm16012", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "799f4d77-24d9-4527-bf0a-c0834026128f"}}}}, {"uuid": "ff26d6fb-1052-422a-81b1-50b88edd8bbd", "name": "", "x": 38.65323563888248, "y": -122.5010289572013, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "43ed408e-35e2-4bca-9060-a0c211aea1e7", "name": "p1rlv15616", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ff26d6fb-1052-422a-81b1-50b88edd8bbd"}}}}, {"uuid": "dc6d07f1-791e-4b94-9a88-dbf295621c02", "name": "", "x": 38.65171836396122, "y": -122.5073219402769, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "135a6a49-6562-4c6e-a41f-f5f78c0ac3e6", "name": "p1rdt7300lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dc6d07f1-791e-4b94-9a88-dbf295621c02"}}}}, {"uuid": "d1113cbb-086c-48b3-8046-8852b680c9f0", "name": "", "x": 38.65167635588258, "y": -122.5073274367839, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dcbee2ff-bf73-4834-bc3c-46fa0cfcad7c", "name": "p1rlv15605", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1113cbb-086c-48b3-8046-8852b680c9f0"}}}}, {"uuid": "dd0c9180-337b-4bc7-a31a-2e7577171c37", "name": "", "x": 38.65243771052424, "y": -122.50266243015153, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7cbc8145-b198-46f1-a3fd-55a05637e618", "name": "p1rdt7303lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dd0c9180-337b-4bc7-a31a-2e7577171c37"}}}}, {"uuid": "73ce9fe1-705c-4d8e-80a9-5002c8210d4b", "name": "", "x": 38.65185163082318, "y": -122.5019234602924, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "13d6bce6-9066-43a1-b2b6-00a2a4398958", "name": "p1rlv15608", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "73ce9fe1-705c-4d8e-80a9-5002c8210d4b"}}}}, {"uuid": "c3756008-99bf-4ec0-be53-adb1369cb151", "name": "", "x": 38.65403878438859, "y": -122.50195031171204, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f5094655-6494-44a9-b0ff-c5b418dcc11e", "name": "p1rdt7308lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c3756008-99bf-4ec0-be53-adb1369cb151"}}}}, {"uuid": "381a41d9-1504-45db-8a4a-b27efaca3000", "name": "", "x": 38.65437369075951, "y": -122.50163017248886, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "905a4857-5d3d-4e51-9ab0-70d634170f92", "name": "p1rlv15619", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "381a41d9-1504-45db-8a4a-b27efaca3000"}}}}, {"uuid": "4fbcffd8-86e8-496d-a8d0-357e53dacafa", "name": "", "x": 38.65414032051154, "y": -122.50185014901611, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4363602a-eb9c-41b8-8130-7bb839f4eb5a", "name": "p1rlv15641", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4fbcffd8-86e8-496d-a8d0-357e53dacafa"}}}}, {"uuid": "8d28b870-3e9d-4d30-9b6a-31be9b81e034", "name": "", "x": 38.65415951784417, "y": -122.50212583870878, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2fba947f-089b-47f3-8720-e8f3e35c097c", "name": "p1rdm16029", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8d28b870-3e9d-4d30-9b6a-31be9b81e034"}}}}, {"uuid": "6011a0aa-03d4-41bc-9cd5-35dc2c621d40", "name": "", "x": 38.65402792759886, "y": -122.50230311224807, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "13f790a1-18c0-498f-8525-fbaf0350947b", "name": "p1rlv15623", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6011a0aa-03d4-41bc-9cd5-35dc2c621d40"}}}}, {"uuid": "7bcce16d-87e0-4d10-8d57-fc5b8f524a87", "name": "", "x": 38.65396880738655, "y": -122.5017823813949, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "154999cc-f6d5-458a-8504-e4692344d372", "name": "p1rdm16030", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7bcce16d-87e0-4d10-8d57-fc5b8f524a87"}}}}, {"uuid": "ced6ff7a-a03f-4dbf-af5e-aade5a1de2b0", "name": "", "x": 38.654067738651435, "y": -122.50173572574505, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bb08eda2-b277-4bfd-9ea0-9c36765400bd", "name": "p1rlv15625", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ced6ff7a-a03f-4dbf-af5e-aade5a1de2b0"}}}}, {"uuid": "ada35336-5f78-4415-b3ea-9cc7c7352964", "name": "", "x": 38.65379214946685, "y": -122.49984533771044, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a289e26d-2d86-4fdf-942b-881b91ca18eb", "name": "p1rdt7316lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ada35336-5f78-4415-b3ea-9cc7c7352964"}}}}, {"uuid": "f1c90b98-2c9f-413b-b598-8e9a43a467cb", "name": "", "x": 38.653302578004016, "y": -122.49982178319588, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ccbef4c-6bf7-4892-a3b9-b51aca495137", "name": "p1rlv15632", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f1c90b98-2c9f-413b-b598-8e9a43a467cb"}}}}, {"uuid": "9249d58e-8a76-44e5-ab7a-bbf6e295e37f", "name": "", "x": 38.65235598284797, "y": -122.5051810906482, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16c465cf-c4ae-4702-ba6c-0b7704eda764", "name": "p1rdt7317lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9249d58e-8a76-44e5-ab7a-bbf6e295e37f"}}}}, {"uuid": "4cde1297-67a1-4116-829e-576e190346d1", "name": "", "x": 38.65233001653422, "y": -122.50513844857348, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ce7b60c8-43ee-441d-9f18-5b2722dcc0a7", "name": "p1rlv15633", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4cde1297-67a1-4116-829e-576e190346d1"}}}}, {"uuid": "36a11850-ce0c-4dc2-9025-e1a728e855f8", "name": "", "x": 38.65388017043282, "y": -122.50146517734701, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c855f7bb-1f33-4c3e-9deb-e3f9c5aba07d", "name": "p1rdt7321lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "36a11850-ce0c-4dc2-9025-e1a728e855f8"}}}}, {"uuid": "70d3109c-f76c-4c96-a280-3e806f70f125", "name": "", "x": 38.654218486038864, "y": -122.50116005048001, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "83c2de51-1b04-483c-8ce7-14b9e5e027b9", "name": "p1rlv15640", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "70d3109c-f76c-4c96-a280-3e806f70f125"}}}}, {"uuid": "540b9bcf-c9d5-4cb2-8966-7c8b6f1c4e02", "name": "", "x": 38.65226101532919, "y": -122.47461094321253, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35be767a-53a1-4fe1-b320-9542dd859d97", "name": "p1rdt7737lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "540b9bcf-c9d5-4cb2-8966-7c8b6f1c4e02"}}}}, {"uuid": "9128b7b1-69e3-423d-ab24-0b8fb59a92b2", "name": "", "x": 38.652194262671, "y": -122.47453893224326, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f5f1e7aa-d93a-4164-8bc0-f920259304a8", "name": "p1rlv16450", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9128b7b1-69e3-423d-ab24-0b8fb59a92b2"}}}}, {"uuid": "45717d17-588c-4eb9-a4be-b1c9e571652a", "name": "", "x": 38.65248920521251, "y": -122.47462474258207, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d9c505d7-3fb9-4eb5-89c6-c9c8da32fd05", "name": "p1rlv16463", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "45717d17-588c-4eb9-a4be-b1c9e571652a"}}}}, {"uuid": "0576c8e0-7b96-4420-b9f8-447650c20d43", "name": "", "x": 38.652235798683144, "y": -122.47438525528987, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "27afe70a-9123-4b0c-9f50-b5355aafcf7a", "name": "p1rlv16507", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0576c8e0-7b96-4420-b9f8-447650c20d43"}}}}, {"uuid": "ea134be6-84da-486d-a0fb-15deb4c9bca9", "name": "", "x": 38.652238275903315, "y": -122.4749368672296, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "344c6b21-94c9-4912-a19e-69fbae5eed27", "name": "p1rlv16584", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea134be6-84da-486d-a0fb-15deb4c9bca9"}}}}, {"uuid": "82e95af2-0e57-4cfe-9c63-c699df52bc84", "name": "", "x": 38.65261600612352, "y": -122.47400628819638, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c7482f0c-eb85-4e30-a09a-eb9f15bbc22b", "name": "p1rdt7753lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "82e95af2-0e57-4cfe-9c63-c699df52bc84"}}}}, {"uuid": "f0d43a70-8ec5-408b-bb0e-9092293d6456", "name": "", "x": 38.652627105759464, "y": -122.4739541259785, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d400b1b2-8404-4b80-b110-6f96e000314f", "name": "p1rlv16475", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f0d43a70-8ec5-408b-bb0e-9092293d6456"}}}}, {"uuid": "83cbec58-3089-49b8-91b1-3572e4a05cab", "name": "", "x": 38.658298169770895, "y": -122.47497347035102, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d343e634-0936-4f21-9e2c-079e19f0dfa1", "name": "p1rdt7757lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "83cbec58-3089-49b8-91b1-3572e4a05cab"}}}}, {"uuid": "b74099d8-228c-463c-a617-41b1b8d455ef", "name": "", "x": 38.65825842964543, "y": -122.47499635592735, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fa6db7ee-126d-4aa9-9733-35ff1c1d5992", "name": "p1rlv16483", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b74099d8-228c-463c-a617-41b1b8d455ef"}}}}, {"uuid": "05f73af5-dbf7-4f27-99c1-3a2dcde31799", "name": "", "x": 38.65819457523532, "y": -122.47482442341177, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0333a34b-4027-4d9a-9d4a-f867c8a317bc", "name": "p1rlv16530", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "05f73af5-dbf7-4f27-99c1-3a2dcde31799"}}}}, {"uuid": "9256eb4c-375b-42f1-8ad0-bcc74e8ae8d9", "name": "", "x": 38.658358587646056, "y": -122.4752254901639, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2f7be042-6681-4694-872d-a1cb701016c7", "name": "p1rlv16541", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9256eb4c-375b-42f1-8ad0-bcc74e8ae8d9"}}}}, {"uuid": "55908553-18e6-47d5-8215-e9cf09c30dea", "name": "", "x": 38.65188446678294, "y": -122.47516262760837, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "28e5f84f-2fac-4b5c-a669-b16988e4d6ae", "name": "p1rdt7791lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "55908553-18e6-47d5-8215-e9cf09c30dea"}}}}, {"uuid": "3e84f813-0859-4f02-bd54-f544f2df4bd7", "name": "", "x": 38.65192675650909, "y": -122.47516097998692, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "90d9dbe9-f9c9-4a4e-8ada-cb459778687b", "name": "p1rlv16573", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e84f813-0859-4f02-bd54-f544f2df4bd7"}}}}, {"uuid": "04928077-4f80-411d-97b8-360cb32be1a4", "name": "", "x": 38.65926840087407, "y": -122.47227383933975, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3959f944-18f5-4daa-a454-3c6bfb7158ff", "name": "p1rdt7795lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "04928077-4f80-411d-97b8-360cb32be1a4"}}}}, {"uuid": "1c69b90b-d0e1-4028-b482-1ca4036e8cc5", "name": "", "x": 38.659242422649335, "y": -122.47223120521224, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4f9ecb3f-8b64-4598-a9d1-d794c6800d33", "name": "p1rlv16604", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1c69b90b-d0e1-4028-b482-1ca4036e8cc5"}}}}, {"uuid": "3a49aadf-859f-4e49-b74b-d23355a7ffe5", "name": "", "x": 38.65559599442719, "y": -122.48692988350368, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b2ec0ba-a854-4631-b97a-4674123d6fe6", "name": "p1rdt8105lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3a49aadf-859f-4e49-b74b-d23355a7ffe5"}}}}, {"uuid": "4ed7c063-ce74-4874-bf3b-1cec6aacd6f6", "name": "", "x": 38.65559859235702, "y": -122.4868763747223, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ba567aae-a893-41d3-8fd1-8357d3cab35d", "name": "p1rlv17239", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ed7c063-ce74-4874-bf3b-1cec6aacd6f6"}}}}, {"uuid": "8ded3db0-024b-49be-9acc-a695799cecde", "name": "", "x": 38.65564415406407, "y": -122.48699097808593, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ac80cbea-e10a-491a-ba36-06e9fcf74217", "name": "p1rlv17280", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8ded3db0-024b-49be-9acc-a695799cecde"}}}}, {"uuid": "e0f12590-98d4-4ed7-88fc-5fa5e8fe6dff", "name": "", "x": 38.65331243461887, "y": -122.48752476984971, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d3a01639-0851-466b-abc6-adf52342e772", "name": "p1rdm17827", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e0f12590-98d4-4ed7-88fc-5fa5e8fe6dff"}}}}, {"uuid": "e1d2445b-e46e-4799-9c98-9252d8c2b600", "name": "", "x": 38.652961085543296, "y": -122.48755025792832, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "acfdbe95-2d82-463a-9d1f-6fd2688adf16", "name": "p1rlv17246", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e1d2445b-e46e-4799-9c98-9252d8c2b600"}}}}, {"uuid": "1bb45f7b-4b3a-4a44-9f4d-3048f9a15419", "name": "", "x": 38.65328712796407, "y": -122.48771232590543, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b639e55-2e33-4582-bb96-06a9d33a3419", "name": "p1rdt8111lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1bb45f7b-4b3a-4a44-9f4d-3048f9a15419"}}}}, {"uuid": "7da01a9e-f940-4a01-ac34-2a764e845b0c", "name": "", "x": 38.653333923034495, "y": -122.48782204194723, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5f70da59-a879-487b-802e-6b7158e425ca", "name": "p1rdm17828", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7da01a9e-f940-4a01-ac34-2a764e845b0c"}}}}, {"uuid": "a34da1cb-8ad8-4e47-b317-055a6b86c735", "name": "", "x": 38.65282666757047, "y": -122.4877236014364, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "04eb7e32-e372-4cb0-94a7-ee418f400bda", "name": "p1rlv17303", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a34da1cb-8ad8-4e47-b317-055a6b86c735"}}}}, {"uuid": "494046db-61b9-449a-9a55-d9608b0d5234", "name": "", "x": 38.65208064789989, "y": -122.48678276121687, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dca9b40e-ed8a-4f75-a703-91539f6c3075", "name": "p1rdt8138lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "494046db-61b9-449a-9a55-d9608b0d5234"}}}}, {"uuid": "7c64b2fd-a133-4a8c-9fcb-743e9393fa45", "name": "", "x": 38.65203864087114, "y": -122.4867882697381, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "04388b89-16fc-40b3-a060-5bc52032874e", "name": "p1rlv17291", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7c64b2fd-a133-4a8c-9fcb-743e9393fa45"}}}}, {"uuid": "1088c6d5-a0f6-4aec-b76a-562b554e8ef7", "name": "", "x": 38.65325699793473, "y": -122.48785970145335, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2bee3961-990e-47ac-b49b-d305f8fe0af8", "name": "p1rdt8146lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1088c6d5-a0f6-4aec-b76a-562b554e8ef7"}}}}, {"uuid": "56ebb882-ddef-4c87-b835-7a021bf78079", "name": "", "x": 38.65356656926306, "y": -122.48793668955402, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "84ebd9bb-dc50-483d-a3c6-044682d4020c", "name": "p1rlv17311", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "56ebb882-ddef-4c87-b835-7a021bf78079"}}}}, {"uuid": "c69bb444-8523-4fdb-99e3-e8c089f4c256", "name": "", "x": 38.66673594751398, "y": -122.46980033939064, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa", "name": "p1rdt8167lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c69bb444-8523-4fdb-99e3-e8c089f4c256"}}}}, {"uuid": "b5629075-98c4-481e-8592-5d57793c505c", "name": "", "x": 38.66651447553529, "y": -122.46928074240148, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8ead5953-70f2-4db2-ba4d-d203c91d85c1", "name": "p1rlv17345", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b5629075-98c4-481e-8592-5d57793c505c"}}}}, {"uuid": "098d3ef0-d2ce-45d0-b04b-b6fa2a56d0b0", "name": "", "x": 38.66618245827339, "y": -122.4695935453166, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf6f74e5-7aa3-4333-bd37-3ce486d54a01", "name": "p1rlv17357", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "098d3ef0-d2ce-45d0-b04b-b6fa2a56d0b0"}}}}, {"uuid": "688ea7b2-7e09-464c-9685-92079311bc8a", "name": "", "x": 38.6673297300225, "y": -122.47020579507135, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d38cdffb-41be-48aa-8a03-c6525dd01037", "name": "p1rlv17397", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "688ea7b2-7e09-464c-9685-92079311bc8a"}}}}, {"uuid": "3dc7dadf-fb8b-4fe0-bf61-9116073c4629", "name": "", "x": 38.66639617857814, "y": -122.46902873548488, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "63177299-2842-4e0d-bf17-7bd2b0afe9a2", "name": "p1rlv17400", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3dc7dadf-fb8b-4fe0-bf61-9116073c4629"}}}}, {"uuid": "ad90541b-98b5-45cd-aea6-3f4573d2327e", "name": "", "x": 38.66678976962103, "y": -122.47037069875277, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b50de14e-9a09-4f61-8998-0979f33b0d0a", "name": "p1rlv17405", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ad90541b-98b5-45cd-aea6-3f4573d2327e"}}}}, {"uuid": "43488034-d332-485e-b8da-3a24da45e181", "name": "", "x": 38.66709595196411, "y": -122.47032246448548, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "86b2527b-73c3-41c4-8ac2-7cb0e8bc2a7a", "name": "p1rlv17415", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "43488034-d332-485e-b8da-3a24da45e181"}}}}, {"uuid": "ff26a39a-d362-48b4-b352-4a4d2839995a", "name": "", "x": 38.66477303429095, "y": -122.46767335323095, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6349165a-d47a-4cf4-84f9-df5c5f3a0e98", "name": "p1rdt8169lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ff26a39a-d362-48b4-b352-4a4d2839995a"}}}}, {"uuid": "443ccb79-9a64-4ac3-b93f-fa60e82b93dd", "name": "", "x": 38.66481200983204, "y": -122.467465715666, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d98640c6-d8aa-44e4-9ecf-5998152d3f7d", "name": "p1rlv17347", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "443ccb79-9a64-4ac3-b93f-fa60e82b93dd"}}}}, {"uuid": "f004f264-53e5-4fd1-8448-926cf4132117", "name": "", "x": 38.664771291883746, "y": -122.46842004356215, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2695decb-d268-46b2-8604-9c33dc90518b", "name": "p1rlv17351", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f004f264-53e5-4fd1-8448-926cf4132117"}}}}, {"uuid": "21b4086a-2833-4014-96f2-2209265c8dbd", "name": "", "x": 38.66479314943949, "y": -122.4672819466205, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9d61897a-cdac-4b4a-8812-8a8692a3d958", "name": "p1rlv17403", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "21b4086a-2833-4014-96f2-2209265c8dbd"}}}}, {"uuid": "f0bd1e1c-ade2-43ea-875c-2be47a63315b", "name": "", "x": 38.661451147924325, "y": -122.47380185053476, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4903e82a-8cfb-406e-b4bf-5e01068419a3", "name": "p1rdt8174lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f0bd1e1c-ade2-43ea-875c-2be47a63315b"}}}}, {"uuid": "56156265-30ca-4fec-b4a3-d59a1ce3950c", "name": "", "x": 38.66119075710339, "y": -122.4737681067613, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f34e3e4e-bebd-4148-bcc7-cbfbecd73a2f", "name": "p1rlv17353", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "56156265-30ca-4fec-b4a3-d59a1ce3950c"}}}}, {"uuid": "8e5ea8b0-2606-496e-b62b-336950b8c3ad", "name": "", "x": 38.66166044070652, "y": -122.47400603929611, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "08709e25-b030-4801-ae00-c4879556d8b1", "name": "p1rlv17378", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8e5ea8b0-2606-496e-b62b-336950b8c3ad"}}}}, {"uuid": "20ce5bab-71b6-436d-abd2-2689fe8b4c7c", "name": "", "x": 38.66156929181106, "y": -122.47377683037024, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e1ad135-904d-47ed-ae74-32b38e1c2f88", "name": "p1rlv17383", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "20ce5bab-71b6-436d-abd2-2689fe8b4c7c"}}}}, {"uuid": "b0fbd10a-9771-4bd7-8373-783698ea0919", "name": "", "x": 38.66528062582966, "y": -122.47017186379257, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e8e03b63-853e-4cfe-bf4a-3779b2026637", "name": "p1rdt8180lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b0fbd10a-9771-4bd7-8373-783698ea0919"}}}}, {"uuid": "51433068-e7bc-4d85-ab18-651de34b6f21", "name": "", "x": 38.665280591504875, "y": -122.4701179030113, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c705333f-6f1a-4a76-a02e-eaa859e99b70", "name": "p1rlv17361", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "51433068-e7bc-4d85-ab18-651de34b6f21"}}}}, {"uuid": "689be9de-1a3d-4405-9fc9-4e242c05dec8", "name": "", "x": 38.66045657865189, "y": -122.47345917790395, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "782d6008-7fec-46b6-9461-9e33b79539d3", "name": "p1rdt8195lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "689be9de-1a3d-4405-9fc9-4e242c05dec8"}}}}, {"uuid": "cb0259a5-54e7-49a0-9eda-41e167976f9b", "name": "", "x": 38.66053224527863, "y": -122.47362350869747, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e835b413-3307-49ef-ad69-cf18a5ae7cfb", "name": "p1rlv17385", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb0259a5-54e7-49a0-9eda-41e167976f9b"}}}}, {"uuid": "1a251dab-2e8e-4c18-aeec-e3ad49945911", "name": "", "x": 38.660557365368454, "y": -122.47319806082461, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "55382019-a1a5-40fd-b90a-072af40c2258", "name": "p1rlv17387", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1a251dab-2e8e-4c18-aeec-e3ad49945911"}}}}, {"uuid": "2a87817d-94cb-4638-8c68-d8fc549cb84a", "name": "", "x": 38.66087354418496, "y": -122.47336814960953, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "169a22de-bb0a-4056-8910-151125c4ff9e", "name": "p1rlv17391", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2a87817d-94cb-4638-8c68-d8fc549cb84a"}}}}, {"uuid": "7e225669-7357-4c5f-a6b8-e6c959f1a8d3", "name": "", "x": 38.66027039448875, "y": -122.47351048965503, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "65de341c-589f-4bf9-a708-26fcc94a6c0a", "name": "p1rlv17407", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7e225669-7357-4c5f-a6b8-e6c959f1a8d3"}}}}, {"uuid": "b9619af0-f534-4ed8-b443-1108e70cd926", "name": "", "x": 38.66016282543937, "y": -122.47363770635508, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "67003f0f-6690-469e-82c0-63949ee5241e", "name": "p1rlv17417", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b9619af0-f534-4ed8-b443-1108e70cd926"}}}}, {"uuid": "1d442fee-a8d8-44b1-b273-76993ff7d240", "name": "", "x": 38.66642010101456, "y": -122.47095566992769, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "76e33e4f-05be-44d1-a503-fed82b4da974", "name": "p1rdt8201lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d442fee-a8d8-44b1-b273-76993ff7d240"}}}}, {"uuid": "fb83ab4d-1060-4dd9-9f30-4b8f22cb1510", "name": "", "x": 38.66660266134409, "y": -122.47084335519723, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ea560bcb-f930-4f42-ae45-3a60f36fdbb7", "name": "p1rlv17394", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fb83ab4d-1060-4dd9-9f30-4b8f22cb1510"}}}}, {"uuid": "48c5cddc-037d-4d5b-b65a-c400b0f007e8", "name": "", "x": 38.66627923556136, "y": -122.47106413182223, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "64a56527-23a9-4229-aa25-f6a45f2187f4", "name": "p1rlv17416", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "48c5cddc-037d-4d5b-b65a-c400b0f007e8"}}}}, {"uuid": "cb371e53-908c-4a9f-a2b4-4fac71dc0dec", "name": "", "x": 38.658114052272616, "y": -122.48189066352298, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8c1f6cd8-cde1-45cc-87ca-1355efa38077", "name": "p1rdt9055lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb371e53-908c-4a9f-a2b4-4fac71dc0dec"}}}}, {"uuid": "76473ac2-56a8-4fac-a4da-1dbaf863b311", "name": "", "x": 38.658139573766896, "y": -122.48184758396665, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be1b9922-2426-4726-9e5a-bcd33f444b57", "name": "p1rlv19616", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "76473ac2-56a8-4fac-a4da-1dbaf863b311"}}}}, {"uuid": "4dc345dd-f015-495c-886a-f88a38d01b1d", "name": "", "x": 38.65791058099435, "y": -122.46275595471984, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "afb4c195-8bb6-47d5-88f3-76adb9cda250", "name": "p1rdt9086lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4dc345dd-f015-495c-886a-f88a38d01b1d"}}}}, {"uuid": "9c47b247-8e1b-4242-9fa7-3d602fc71749", "name": "", "x": 38.657936095394604, "y": -122.46271286857773, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "19894180-0890-4585-b4e2-55500af3c41a", "name": "p1rlv19683", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9c47b247-8e1b-4242-9fa7-3d602fc71749"}}}}, {"uuid": "78134a20-f557-4c7c-bdfc-f58d76af56d2", "name": "", "x": 38.69033987948928, "y": -122.31517238474055, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "40b03cbe-470d-493a-854a-900557ac20c8", "name": "p1rdt16394lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "78134a20-f557-4c7c-bdfc-f58d76af56d2"}}}}, {"uuid": "c5989fcd-1f6f-4491-88d2-00fe769d047a", "name": "", "x": 38.690138170140635, "y": -122.31563821475763, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f827fe9e-1ffe-456c-a57b-c3374aef8ad8", "name": "p1rlv37689", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c5989fcd-1f6f-4491-88d2-00fe769d047a"}}}}, {"uuid": "f89b95b1-f645-487d-b039-3554fc023a6f", "name": "", "x": 38.69038758916915, "y": -122.3151414107498, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "da3cd593-6f05-41ba-9609-f6f1e307e998", "name": "p1rlv37691", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f89b95b1-f645-487d-b039-3554fc023a6f"}}}}, {"uuid": "c45145a7-e48a-45a9-b733-91ed9471b83f", "name": "", "x": 38.690565522935835, "y": -122.31474877047064, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "01c9efda-0adf-4932-8f54-2938964371d2", "name": "p1rlv37703", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c45145a7-e48a-45a9-b733-91ed9471b83f"}}}}, {"uuid": "065fe856-5120-4d7c-96e9-00c8304e4ee3", "name": "", "x": 38.68956634076771, "y": -122.30929268806497, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "38b0bd7c-0898-497f-bb24-4add0fd92932", "name": "p1rdt16404lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "065fe856-5120-4d7c-96e9-00c8304e4ee3"}}}}, {"uuid": "f48745c0-959b-4078-b13d-3e5d27fd30a0", "name": "", "x": 38.68932901734512, "y": -122.30982786050683, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "38bda697-2888-467e-bab0-62896a62503f", "name": "p1rlv37710", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f48745c0-959b-4078-b13d-3e5d27fd30a0"}}}}, {"uuid": "a534a629-8809-4af4-8251-f12881581d93", "name": "", "x": 38.68985442947351, "y": -122.30876497515673, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f8d998a0-628e-4009-a6c8-07af906f6d43", "name": "p1rlv37732", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a534a629-8809-4af4-8251-f12881581d93"}}}}, {"uuid": "f671dd9e-c96a-4c72-a7f2-32b8324f73df", "name": "", "x": 38.71319629081823, "y": -122.2618537891679, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "58dce206-0571-4a37-b24b-2e674e0c0d3b", "name": "p1rdm37174", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f671dd9e-c96a-4c72-a7f2-32b8324f73df"}}}}, {"uuid": "3dc216d4-8c44-41bb-a2eb-0d33315315ef", "name": "", "x": 38.713341484062944, "y": -122.26201332345111, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b24da1e-9a6e-4545-9ad4-a9f0e9675fd1", "name": "p1rlv37776", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3dc216d4-8c44-41bb-a2eb-0d33315315ef"}}}}, {"uuid": "0344c586-dfad-4b14-85d0-f6ac8106e33a", "name": "", "x": 38.71333206265715, "y": -122.26149980897426, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "23775c66-0b90-443d-8566-491405876e9d", "name": "p1rdt16424lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0344c586-dfad-4b14-85d0-f6ac8106e33a"}}}}, {"uuid": "990f60d2-63fa-4bd2-86bb-fd9b7e60eaad", "name": "", "x": 38.713372298566235, "y": -122.26118486465606, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d21a9584-0fe7-48a6-a46e-ac33e948a471", "name": "p1rdm37175", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "990f60d2-63fa-4bd2-86bb-fd9b7e60eaad"}}}}, {"uuid": "f5b8af75-ea5b-40bf-ba70-84760d41fac7", "name": "", "x": 38.71352621311042, "y": -122.26129830022444, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f5aaed5d-8312-4707-a047-634e433bf49f", "name": "p1rlv37778", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5b8af75-ea5b-40bf-ba70-84760d41fac7"}}}}, {"uuid": "72f2febe-f3c7-4987-8225-28831e04951b", "name": "", "x": 38.71269200809747, "y": -122.26236108033618, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "980376ed-54fd-434c-b58e-0bbd6eaa9954", "name": "p1rdt16427lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "72f2febe-f3c7-4987-8225-28831e04951b"}}}}, {"uuid": "16355f17-6818-4e54-8516-4c17b62d5f1e", "name": "", "x": 38.71269522836307, "y": -122.26242253360313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0d7181ee-ef64-4ded-b619-00ac09d55bf5", "name": "p1rlv37782", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "16355f17-6818-4e54-8516-4c17b62d5f1e"}}}}, {"uuid": "ba848da2-4966-44bb-878b-7dc0e31f2430", "name": "", "x": 38.684304380145115, "y": -122.31768680277943, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "26bc650a-6838-4320-8afa-b8d2f22e96e8", "name": "p1rdt16603lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ba848da2-4966-44bb-878b-7dc0e31f2430"}}}}, {"uuid": "dcfb8e68-db83-4b06-a59d-4820b9154406", "name": "", "x": 38.68458254841867, "y": -122.31796762036473, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "10be49a0-301a-4c7e-8ab7-49c14e483079", "name": "p1rlv38046", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dcfb8e68-db83-4b06-a59d-4820b9154406"}}}}, {"uuid": "bb368911-48db-4b83-b838-5c483aa7c0a3", "name": "", "x": 38.68382003837408, "y": -122.31702058531167, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0935a86b-b9fb-4058-8381-a41f67d6c9dd", "name": "p1rlv38047", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bb368911-48db-4b83-b838-5c483aa7c0a3"}}}}, {"uuid": "fd245f8b-6db6-41f1-b94c-9b6191e22523", "name": "", "x": 38.684447916688484, "y": -122.31806087736241, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9db6122d-1e51-46ac-9cea-ac436e189cd8", "name": "p1rlv38052", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fd245f8b-6db6-41f1-b94c-9b6191e22523"}}}}, {"uuid": "867a88ab-030c-47f8-8e55-ba767e4fd31c", "name": "", "x": 38.68318595308261, "y": -122.31906558684712, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d31da07-e20a-4fb8-95f4-d91450395471", "name": "p1rdt16604lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "867a88ab-030c-47f8-8e55-ba767e4fd31c"}}}}, {"uuid": "a92bf90f-f106-4803-b7cd-a94b7ec6a0e7", "name": "", "x": 38.68325558877688, "y": -122.31912993455164, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5da7ff68-5f4c-4d56-88fc-7736df03c0bf", "name": "p1rlv38048", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a92bf90f-f106-4803-b7cd-a94b7ec6a0e7"}}}}, {"uuid": "1be34c71-cd62-4229-a445-4640d75a7920", "name": "", "x": 38.683074628268045, "y": -122.31900518071453, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cafc6c03-240d-499d-a3d8-983b554dd007", "name": "p1rlv38050", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1be34c71-cd62-4229-a445-4640d75a7920"}}}}, {"uuid": "85f3f994-ebf6-4123-8306-7c66f4fe90fe", "name": "", "x": 38.72488522966494, "y": -122.31175617505791, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a4a3b828-bddf-4314-b9a5-03b9dfcd2618", "name": "p1rdt16787lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "85f3f994-ebf6-4123-8306-7c66f4fe90fe"}}}}, {"uuid": "4cb84e15-fc68-4ec5-ab40-cf063445d1c9", "name": "", "x": 38.72480906566549, "y": -122.31154585900022, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a25b3511-86cf-404e-944f-273d3f94c05a", "name": "p1rlv38414", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4cb84e15-fc68-4ec5-ab40-cf063445d1c9"}}}}, {"uuid": "a1e6aa75-b873-4007-a204-cf87e0d543ff", "name": "", "x": 38.724919569400605, "y": -122.3119474333546, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a6e4595c-0ad9-4501-b86f-c559917d4b86", "name": "p1rlv38419", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a1e6aa75-b873-4007-a204-cf87e0d543ff"}}}}, {"uuid": "37841bc9-c1dc-4418-bcb3-7309b15e549c", "name": "", "x": 38.725467899287466, "y": -122.31258369528427, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9c261090-bc22-4d81-9a9e-75227cd7c99e", "name": "p1rdt16790lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "37841bc9-c1dc-4418-bcb3-7309b15e549c"}}}}, {"uuid": "788ddba8-11aa-4aa0-8e92-f9c2adc10b3d", "name": "", "x": 38.725441863299416, "y": -122.312541080781, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "201112bb-3dc7-4a15-9af6-155626ac1ae5", "name": "p1rlv38417", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "788ddba8-11aa-4aa0-8e92-f9c2adc10b3d"}}}}, {"uuid": "5793a67e-5c04-4b95-ba75-d4fe24c7dea9", "name": "", "x": 38.69566612075781, "y": -122.29850531296424, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e1abef1d-4ffc-4696-91ca-e81ac36cce61", "name": "p1rdt16847lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5793a67e-5c04-4b95-ba75-d4fe24c7dea9"}}}}, {"uuid": "a380a296-2b02-4d46-bfde-f814f84ed80a", "name": "", "x": 38.695297864066646, "y": -122.29823690772227, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a0764c32-4f46-473a-9a72-cccc45ae28d7", "name": "p1rlv38535", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a380a296-2b02-4d46-bfde-f814f84ed80a"}}}}, {"uuid": "14b0b62d-7296-422d-9cc1-708bd7167a8c", "name": "", "x": 38.69607606503067, "y": -122.29876976693473, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5ff930f9-63f0-4cab-b74a-3db7eb99f9eb", "name": "p1rlv38536", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "14b0b62d-7296-422d-9cc1-708bd7167a8c"}}}}, {"uuid": "4d757316-db89-48f9-b906-07965b862b6a", "name": "", "x": 38.74356263285725, "y": -122.27336627842594, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0df1550a-7e69-42e9-8059-3a36ecb3d253", "name": "p1rdt16911lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d757316-db89-48f9-b906-07965b862b6a"}}}}, {"uuid": "28b52fe4-3ee2-48fe-9797-05cbf31832d3", "name": "", "x": 38.74357721508068, "y": -122.27335107450713, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4a3851f7-2dd3-447b-918f-7a8c954f21d1", "name": "p1rlv38638", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "28b52fe4-3ee2-48fe-9797-05cbf31832d3"}}}}, {"uuid": "752654c3-b2fa-4808-8238-2c2cfff7aadc", "name": "", "x": 38.67909765473299, "y": -122.51997053087246, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d49257c8-f8eb-4024-9c02-461d18cdd3d5", "name": "p1rdt383", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "752654c3-b2fa-4808-8238-2c2cfff7aadc"}}}}, {"uuid": "46aeb7f3-d13e-4a01-8839-fdd865ccf46d", "name": "", "x": 38.67949973700607, "y": -122.52574842403467, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8d8cd980-268f-4adb-a6ee-70edf7784542", "name": "p1rdt383-p1rdt384x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "46aeb7f3-d13e-4a01-8839-fdd865ccf46d"}}}}, {"uuid": "a23443c6-1d62-4ffa-9f5b-5736dfcce6aa", "name": "", "x": 38.6790657111712, "y": -122.52914676125815, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7adf2f4b-f0fd-4c53-abcf-d90fe1a2b4c4", "name": "p1rdt384", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a23443c6-1d62-4ffa-9f5b-5736dfcce6aa"}}}}, {"uuid": "90950951-2a50-4431-b77b-57d9b3dbe8c7", "name": "", "x": 38.651801942472055, "y": -122.5073324871614, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f9240d01-bf5d-41ed-8c53-c1f04af1a236", "name": "p1rdt383-p1rdt7300x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "90950951-2a50-4431-b77b-57d9b3dbe8c7"}}}}, {"uuid": "4d44044a-2d92-4b3c-9aab-774930b93609", "name": "", "x": 38.65515241674437, "y": -122.50889970027711, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e5ac1506-77e9-4b90-ad3d-18be099063a9", "name": "p1rdt383-p1rdt7300x_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d44044a-2d92-4b3c-9aab-774930b93609"}}}}, {"uuid": "05fc9700-79a2-4dc4-bf3d-f5de2a903094", "name": "", "x": 38.653733535353965, "y": -122.50089156658129, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d065da7b-7e88-4e63-a47c-959f4d4c6e1c", "name": "p1rdt7299", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "05fc9700-79a2-4dc4-bf3d-f5de2a903094"}}}}, {"uuid": "c914feb5-e9de-422b-aeaf-cfc62dd17293", "name": "", "x": 38.65375040418197, "y": -122.49983768034305, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6322bf4d-0976-4bae-94c0-f76f83ccb9bf", "name": "p1rdt7316", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c914feb5-e9de-422b-aeaf-cfc62dd17293"}}}}, {"uuid": "ab222d15-220f-49d0-9978-7493ba856d51", "name": "", "x": 38.65383842524826, "y": -122.5014575190295, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b468be25-1324-46ab-9424-887741ca1134", "name": "p1rdt7321", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ab222d15-220f-49d0-9978-7493ba856d51"}}}}, {"uuid": "9819f669-9c19-41ec-86fe-e3a06b9a4003", "name": "", "x": 38.65408052954152, "y": -122.50195797033598, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d2e605b4-fe7a-4571-947d-8ae19de627d8", "name": "p1rdt7308", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9819f669-9c19-41ec-86fe-e3a06b9a4003"}}}}, {"uuid": "dd3454db-2254-4e87-a37a-95cfce8f56ef", "name": "", "x": 38.65442560903119, "y": -122.50257618415456, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a955da2d-e212-4026-b1fb-0021a04ded07", "name": "p1rdt7294", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dd3454db-2254-4e87-a37a-95cfce8f56ef"}}}}, {"uuid": "27154954-bf7a-47cd-b84f-cfe43e152146", "name": "", "x": 38.652479455643565, "y": -122.5026700890289, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e6f24e3a-088a-4d1b-8292-03015289d88e", "name": "p1rdt7303", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "27154954-bf7a-47cd-b84f-cfe43e152146"}}}}, {"uuid": "ac160d78-43c2-4240-98f5-e6ae472758ac", "name": "", "x": 38.652370317308936, "y": -122.50523190353242, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48efebbb-c70a-47d3-aae3-0e39088fc455", "name": "p1rdt7317", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ac160d78-43c2-4240-98f5-e6ae472758ac"}}}}, {"uuid": "03e38011-c0fb-4e11-9933-4cd3cac852ba", "name": "", "x": 38.65220758039855, "y": -122.50510436245315, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e9980c6-3edc-4b4a-be98-cec731419c30", "name": "p1rdt7303-p1rdt7317x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "03e38011-c0fb-4e11-9933-4cd3cac852ba"}}}}, {"uuid": "5860e8c6-343d-4d04-bad2-41ef009e292b", "name": "", "x": 38.65176065727734, "y": -122.50732046975546, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "05f14a3e-053e-4b65-b962-da7804b9e2c1", "name": "p1rdt7300", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5860e8c6-343d-4d04-bad2-41ef009e292b"}}}}, {"uuid": "07ba29a5-2151-46cd-a5ab-f359ec3ab19c", "name": "", "x": 38.64755417890137, "y": -122.50920989641365, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "47f8ed28-4bff-47d9-8ffe-4509e9c5b7fc", "name": "p1rdt6488-p1rdt7300x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "07ba29a5-2151-46cd-a5ab-f359ec3ab19c"}}}}, {"uuid": "2f8c22fe-e901-48d9-9eef-46f361d4dc9c", "name": "", "x": 38.64759956755727, "y": -122.50867546400877, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b96c1e20-68ac-4548-a068-86483c7fa921", "name": "p1rdt6488-p1rdt7300xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2f8c22fe-e901-48d9-9eef-46f361d4dc9c"}}}}, {"uuid": "0840458c-3040-4065-b329-753f2e9edfff", "name": "", "x": 38.659282749601154, "y": -122.47232465037078, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bee93ff6-6ff8-4572-b339-c8e897dac81b", "name": "p1rdt7795", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0840458c-3040-4065-b329-753f2e9edfff"}}}}, {"uuid": "218dc36b-329c-4f26-a80d-dc68a2c4a6cc", "name": "", "x": 38.65789678232331, "y": -122.46280701212554, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75ee3b24-7407-45ba-94d5-abe187306f13", "name": "p1rdt9086", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "218dc36b-329c-4f26-a80d-dc68a2c4a6cc"}}}}, {"uuid": "ead0976b-5a32-4ecb-90c0-3f17d38fc9bf", "name": "", "x": 38.6582588467901, "y": -122.47506760778616, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0cd22d3e-1e2a-4a99-9967-b9df95837915", "name": "p1rdt7757-p1rdt7795x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ead0976b-5a32-4ecb-90c0-3f17d38fc9bf"}}}}, {"uuid": "575a3212-4155-4852-a5f4-bb331a4bbb26", "name": "", "x": 38.66713136194248, "y": -122.47883578171474, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "53e5fee4-5a31-448e-8bd0-d8996468d085", "name": "p1rdt6261", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "575a3212-4155-4852-a5f4-bb331a4bbb26"}}}}, {"uuid": "c526aa31-5e92-4d33-af90-0c67bd587449", "name": "", "x": 38.66662516142702, "y": -122.47987793918193, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6c00c7b1-0aec-4669-9679-cbc1476e0526", "name": "p1rdt6261-p1rdt6262x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c526aa31-5e92-4d33-af90-0c67bd587449"}}}}, {"uuid": "8d4d5410-3d6d-4a36-8d81-2eb1e14929e8", "name": "", "x": 38.66651499085745, "y": -122.4800586749112, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf092ec9-ecda-4216-9ac0-0bc035973515", "name": "p1rdt6262", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8d4d5410-3d6d-4a36-8d81-2eb1e14929e8"}}}}, {"uuid": "4c9a6417-dd7e-4201-97f3-4b1de459f448", "name": "", "x": 38.666918119613086, "y": -122.48091258305858, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c61df077-693e-4e67-aea6-ee60b99406d1", "name": "p1rdt6263", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c9a6417-dd7e-4201-97f3-4b1de459f448"}}}}, {"uuid": "7ca3f583-3b6e-4756-99c2-2beee9dd510f", "name": "", "x": 38.66244739498498, "y": -122.4766461808176, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e22d08f0-2afc-426a-a0c0-6b00cc1103aa", "name": "p1rdt6266", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7ca3f583-3b6e-4756-99c2-2beee9dd510f"}}}}, {"uuid": "dfcbece4-24cf-4df0-b723-98cebf605a35", "name": "", "x": 38.663631853304395, "y": -122.47754329911722, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cab917a3-5cc2-46d5-9cee-971591841f12", "name": "p1rdt6261-p1rdt6266x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dfcbece4-24cf-4df0-b723-98cebf605a35"}}}}, {"uuid": "d4d80403-25d9-41a5-9e44-5bc2e1041169", "name": "", "x": 38.66255554922429, "y": -122.47735618000138, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4a03d20d-664a-4e80-abec-a36910787829", "name": "p1rdt6264", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d4d80403-25d9-41a5-9e44-5bc2e1041169"}}}}, {"uuid": "7f90f9c9-ada7-4545-805f-74e7ff76cce2", "name": "", "x": 38.66324435870563, "y": -122.47754611470971, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9b6508ce-e51b-4173-8b54-3f3eb7a2cd71", "name": "p1rdt6266-p1rdt6267x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7f90f9c9-ada7-4545-805f-74e7ff76cce2"}}}}, {"uuid": "edabaa6d-c4da-4492-a840-5b6a75d9064f", "name": "", "x": 38.66526274271137, "y": -122.47948778772573, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a1d9cfa7-0024-4896-a263-2715086f2ad6", "name": "p1rdt6267", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "edabaa6d-c4da-4492-a840-5b6a75d9064f"}}}}, {"uuid": "3d879b6c-dee9-4e19-a2b9-c9353631ef11", "name": "", "x": 38.66146360124312, "y": -122.4739001517938, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d07105ef-1ba3-4775-aeb4-650b5ea8736e", "name": "p1rdt6266-p1rdt8174x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3d879b6c-dee9-4e19-a2b9-c9353631ef11"}}}}, {"uuid": "fa6491bf-299d-44eb-ad2d-891e877aa105", "name": "", "x": 38.75306841044715, "y": -122.36663378364803, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "79d0fee6-369b-4f95-a2d2-cd05232652e3", "name": "p1rdt181", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa6491bf-299d-44eb-ad2d-891e877aa105"}}}}, {"uuid": "c072f967-5c31-42c3-8e9b-35184b126f3f", "name": "", "x": 38.754868310420626, "y": -122.36837472635783, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "24681ab1-3904-4509-85e6-d9bb1dba4c8e", "name": "p1rdt181_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c072f967-5c31-42c3-8e9b-35184b126f3f"}}}}, {"uuid": "2ad22731-6846-4b63-baa9-765766802509", "name": "", "x": 38.771927561946114, "y": -122.36440291040475, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0d4e6a87-0313-419f-8feb-7ea3a29f59ae", "name": "p1rdt275", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2ad22731-6846-4b63-baa9-765766802509"}}}}, {"uuid": "665fada7-7a88-4136-9eab-40f5c884f0b2", "name": "", "x": 38.78773053668457, "y": -122.34702184190017, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1a85646-be2b-4b15-9c2f-cc603c7e06df", "name": "p1rdt253", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "665fada7-7a88-4136-9eab-40f5c884f0b2"}}}}, {"uuid": "b4b135e0-c9a9-4999-9448-44a19e6f2767", "name": "", "x": 38.76715093535089, "y": -122.36057334237034, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eb9e5f0f-8bcf-4019-a786-3f24334e9ae7", "name": "p1rdt68", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b4b135e0-c9a9-4999-9448-44a19e6f2767"}}}}, {"uuid": "32e939e4-5261-4ed7-9bef-2dc70b0e4447", "name": "", "x": 38.77038045634796, "y": -122.36232121374398, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8435bee2-05ea-4208-9520-809129624d70", "name": "p1rdt275-p1rdt68x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "32e939e4-5261-4ed7-9bef-2dc70b0e4447"}}}}, {"uuid": "54cceeea-9aa0-4d66-8115-b4b848862660", "name": "", "x": 38.762804233208215, "y": -122.3567217728313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e9cb7919-b8bd-46c1-a173-90a5d241c46e", "name": "p1rdt280", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "54cceeea-9aa0-4d66-8115-b4b848862660"}}}}, {"uuid": "8845fc18-33d7-47e8-a26b-2bf3b16d7ee2", "name": "", "x": 38.754224477281774, "y": -122.36483177825646, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ac745c6f-6e78-4a68-affa-649f91d3aa7c", "name": "p1rdt281", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8845fc18-33d7-47e8-a26b-2bf3b16d7ee2"}}}}, {"uuid": "cd2affdb-33a9-4f80-bda0-c84fa9ffaa09", "name": "", "x": 38.762332092473166, "y": -122.35720189679247, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4425707e-f2b0-419f-828e-a4642ee34b5a", "name": "p1rdt280-p1rdt281x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cd2affdb-33a9-4f80-bda0-c84fa9ffaa09"}}}}, {"uuid": "d1a7b63c-63eb-4950-aaa9-c61ee1ba140b", "name": "", "x": 38.72318515388558, "y": -122.41088395202819, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2fddf29e-6eef-4c60-ad8b-4580440973b3", "name": "p1rdt181-p1rdt297x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1a7b63c-63eb-4950-aaa9-c61ee1ba140b"}}}}, {"uuid": "851a2f84-14c6-409d-8071-4667378696d9", "name": "", "x": 38.726937156537616, "y": -122.40539968889463, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d87f56c0-0a3f-4a94-8f60-1ece461290d0", "name": "p1rdt181-p1rdt297x_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "851a2f84-14c6-409d-8071-4667378696d9"}}}}, {"uuid": "759e1907-5ba4-48d6-919d-b558f46832b1", "name": "", "x": 38.759945311222936, "y": -122.44222861124264, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "170a2bcb-d7ce-4617-855b-9111b84262ed", "name": "p1rdt3776", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "759e1907-5ba4-48d6-919d-b558f46832b1"}}}}, {"uuid": "7668d332-5379-4200-a145-37c5d95aa7ac", "name": "", "x": 38.75895331123435, "y": -122.44467277060775, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5f9af980-79c4-4daf-b8fc-44e02953f98b", "name": "p1rdt3777", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7668d332-5379-4200-a145-37c5d95aa7ac"}}}}, {"uuid": "02b963dd-7858-4cea-b384-6910759c8ab5", "name": "", "x": 38.7505314706947, "y": -122.41545810153862, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7eca59ac-01f1-40d7-a0ec-51f355285e01", "name": "p1rdt270", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "02b963dd-7858-4cea-b384-6910759c8ab5"}}}}, {"uuid": "0006edd5-9a24-4cdf-8952-aeacecc849f2", "name": "", "x": 38.75941275867633, "y": -122.44145409385084, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6168ebbc-8fd5-49a0-94db-887814eceaba", "name": "p1rdt270-p1rdt3776x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0006edd5-9a24-4cdf-8952-aeacecc849f2"}}}}, {"uuid": "27c267c2-ebc5-4f52-93a6-6ee6fa420984", "name": "", "x": 38.724404971590296, "y": -122.41244167570912, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e2c76250-d7ea-4da4-8008-dac1a579e974", "name": "p1rdt270-p1rdt298x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "27c267c2-ebc5-4f52-93a6-6ee6fa420984"}}}}, {"uuid": "b13b2b3e-f03d-40da-ab3d-d9146809b14f", "name": "", "x": 38.72936375125469, "y": -122.41301863676793, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ac7c613f-190c-493e-8e89-3ef48e8efdb9", "name": "p1rdt270-p1rdt298x_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b13b2b3e-f03d-40da-ab3d-d9146809b14f"}}}}, {"uuid": "f23ba844-eefe-4850-91bd-642274b7cd43", "name": "", "x": 38.72321115431449, "y": -122.41092660136522, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d32493ec-06be-48ef-959e-779c79c507a3", "name": "p1rdt297", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f23ba844-eefe-4850-91bd-642274b7cd43"}}}}, {"uuid": "f64c9648-faca-44e7-8a97-9c3c8dc95507", "name": "", "x": 38.72444619013448, "y": -122.4124539994752, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7a468f13-c61f-4c01-aa27-c75fb02030e0", "name": "p1rdt298", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f64c9648-faca-44e7-8a97-9c3c8dc95507"}}}}, {"uuid": "546b8fad-55ef-4415-a10c-2b3d67c1758c", "name": "", "x": 38.716932571899626, "y": -122.4194260124673, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "91f76b91-e00a-4a88-8ee8-ec403c2c7d96", "name": "p1rdt385", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "546b8fad-55ef-4415-a10c-2b3d67c1758c"}}}}, {"uuid": "5c83ea19-2401-4a56-b711-6b8cc4186995", "name": "", "x": 38.70723340886135, "y": -122.42474689668317, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "22179eaa-fd19-4619-8b31-52bcb36ec683", "name": "p1rdt252-p1rdt385x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5c83ea19-2401-4a56-b711-6b8cc4186995"}}}}, {"uuid": "215d5350-57f3-47a2-ad91-9221da3b8bdc", "name": "", "x": 38.7068487847659, "y": -122.42495904757907, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f9c899bc-796a-4e92-88db-6aa11f8777cb", "name": "p1rdt251-p1rdt254x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "215d5350-57f3-47a2-ad91-9221da3b8bdc"}}}}, {"uuid": "ef1d5226-a8f9-4454-a993-7cb000b03794", "name": "", "x": 38.706847489569306, "y": -122.42594987463313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ab802e3-3a0a-413c-8865-e3b3d08e44a8", "name": "p1rdt254", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef1d5226-a8f9-4454-a993-7cb000b03794"}}}}, {"uuid": "3c286a77-6cc8-436e-9fc7-c2d3036ddaba", "name": "", "x": 38.69595800578408, "y": -122.39252013725728, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8e28087b-b80e-4043-b0f0-0bc82c91f5e8", "name": "p1rdt258", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3c286a77-6cc8-436e-9fc7-c2d3036ddaba"}}}}, {"uuid": "804b2239-d5e8-48c0-9827-b37ecf5b0754", "name": "", "x": 38.697506302675386, "y": -122.39110055463347, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf660777-f77e-4d9b-afff-73a84274c270", "name": "p1rdt262", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "804b2239-d5e8-48c0-9827-b37ecf5b0754"}}}}, {"uuid": "c54df0ed-ada6-4bb9-a22a-77c5b1643b95", "name": "", "x": 38.6960521884224, "y": -122.39265347986003, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "209cebda-044a-42a3-b2f0-fe5b76b80643", "name": "p1rdt261", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c54df0ed-ada6-4bb9-a22a-77c5b1643b95"}}}}, {"uuid": "c2026069-787d-446d-98d6-de87e2aceec7", "name": "", "x": 38.696015106037905, "y": -122.39255812819005, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be0fa139-8da7-4cba-9e49-faf4a4814035", "name": "p1rdt258-p1rdt261x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c2026069-787d-446d-98d6-de87e2aceec7"}}}}, {"uuid": "4caf55e0-0b8c-407e-811a-83af58390919", "name": "", "x": 38.69712125423101, "y": -122.39909419849987, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bbe3ac37-aca0-47fd-ac5d-be390cad10ab", "name": "p1rdt261-p1rdt277x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4caf55e0-0b8c-407e-811a-83af58390919"}}}}, {"uuid": "4f2e309d-192c-4ca8-a1de-e92bdeb74d0c", "name": "", "x": 38.702132662964175, "y": -122.38784923319449, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a2b529c9-4695-42f3-a0e3-69bbb34ff285", "name": "p1rdt37-p1rdt80x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4f2e309d-192c-4ca8-a1de-e92bdeb74d0c"}}}}, {"uuid": "81d8b59a-049e-4f0c-be85-a34d084e4b44", "name": "", "x": 38.70165469665771, "y": -122.38758437608678, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9dcbfdc3-b597-4e9e-a86f-4d0ff396ba70", "name": "p1rdt37", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "81d8b59a-049e-4f0c-be85-a34d084e4b44"}}}}, {"uuid": "8f6e7c1a-1fd0-4353-ae0c-01e914a08470", "name": "", "x": 38.70226336170039, "y": -122.37889294477628, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a9c4411-f402-464c-ad25-d439b87ef768", "name": "p1rdt34", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8f6e7c1a-1fd0-4353-ae0c-01e914a08470"}}}}, {"uuid": "df30e6d5-4f96-4c9e-822f-7dc4d01fc1c6", "name": "", "x": 38.70240564817688, "y": -122.37853520540186, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "31b06630-2aae-4fe7-9e31-f911c91121cd", "name": "p1rdt77", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "df30e6d5-4f96-4c9e-822f-7dc4d01fc1c6"}}}}, {"uuid": "07e40688-ddb5-443c-82d8-7dfb1870c9b0", "name": "", "x": 38.70192539724856, "y": -122.37910641908904, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b45513a3-8e88-45e9-99d3-6d244c90c256", "name": "p1rdt38", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "07e40688-ddb5-443c-82d8-7dfb1870c9b0"}}}}, {"uuid": "26fcf062-38f3-4fc4-944a-64a938b61bab", "name": "", "x": 38.70129185446362, "y": -122.37973917584448, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "668d32be-c07a-4387-86a5-e9754af11e9c", "name": "p1rdt31-p1rdt38x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "26fcf062-38f3-4fc4-944a-64a938b61bab"}}}}, {"uuid": "ed47d79a-4bc3-482c-a4a9-cbd1e0f3ff3d", "name": "", "x": 38.701554940346995, "y": -122.37742353030349, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2b82a9a2-b1d1-44eb-a451-946643ef613d", "name": "p1rdt74-p1rdt85x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ed47d79a-4bc3-482c-a4a9-cbd1e0f3ff3d"}}}}, {"uuid": "eea93f53-2784-47ad-9645-52baa3baf1fb", "name": "", "x": 38.702210844779025, "y": -122.37749036925975, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b884fef-8b8f-4ed5-9033-b8177d1c7d70", "name": "p1rdt74", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eea93f53-2784-47ad-9645-52baa3baf1fb"}}}}, {"uuid": "147c7c3d-719e-47e9-9fbe-5d5d89ded094", "name": "", "x": 38.69878213406897, "y": -122.37500166002606, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf205ba7-ac66-4318-aeca-c75eb96cbd1e", "name": "p1rdt456", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "147c7c3d-719e-47e9-9fbe-5d5d89ded094"}}}}, {"uuid": "16e64a55-a47c-4563-9842-a45162327cac", "name": "", "x": 38.698844229551156, "y": -122.37481712432647, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cee642e7-12f0-4746-841e-d8cda6fff57e", "name": "p1rdt489", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "16e64a55-a47c-4563-9842-a45162327cac"}}}}, {"uuid": "2156d576-a0de-4c7f-8b6b-83a2796d5de4", "name": "", "x": 38.698450220223094, "y": -122.375819293565, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b092ee09-4c5e-46b5-8ec2-51f99254c220", "name": "p1rdt456-p1rdt465x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2156d576-a0de-4c7f-8b6b-83a2796d5de4"}}}}, {"uuid": "154ca468-f940-41a0-813f-c7a6390c0c78", "name": "", "x": 38.693782143657465, "y": -122.37465775612712, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "05082892-d69e-4c8f-ba19-c2a627e1c345", "name": "p1rdt46", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "154ca468-f940-41a0-813f-c7a6390c0c78"}}}}, {"uuid": "c6b93af1-6cb1-4ff7-847d-a8f8e24da09c", "name": "", "x": 38.69314320252447, "y": -122.37482430214054, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "50f3b5f3-3fb5-4fb9-b2e6-b37200af0901", "name": "p1rdt70", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c6b93af1-6cb1-4ff7-847d-a8f8e24da09c"}}}}, {"uuid": "c1697cd7-1b88-45cc-b5f6-415d8eb7a1bc", "name": "", "x": 38.69495141442872, "y": -122.3748625110079, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b61caefd-d5aa-4019-9ac0-aaf8cedc71d0", "name": "p1rdt458", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c1697cd7-1b88-45cc-b5f6-415d8eb7a1bc"}}}}, {"uuid": "886222cb-cab4-4cd2-836a-660c88e16dfa", "name": "", "x": 38.69185315698694, "y": -122.37350964662168, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2faff95d-f394-427a-9d62-75224f830c9e", "name": "p1rdt72", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "886222cb-cab4-4cd2-836a-660c88e16dfa"}}}}, {"uuid": "0ee4f148-fd6a-46ed-ad40-dd2c07a2bdea", "name": "", "x": 38.69169101529133, "y": -122.37352255937813, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a6fb1323-f697-4423-a70d-838056200402", "name": "p1rdt52", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0ee4f148-fd6a-46ed-ad40-dd2c07a2bdea"}}}}, {"uuid": "ec8d68dd-493a-4fc5-92b6-8771c3237b37", "name": "", "x": 38.693098193510316, "y": -122.37377475782415, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "137c345c-77cc-4324-bc0e-e0ba896a5f43", "name": "p1rdt49", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ec8d68dd-493a-4fc5-92b6-8771c3237b37"}}}}, {"uuid": "0990a9d9-e9d3-40e6-8e79-7a8bd3f851c3", "name": "", "x": 38.694135169317704, "y": -122.37389220491741, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1d8f5898-7d36-4e40-9980-76d11ef18adb", "name": "p1rdt56", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0990a9d9-e9d3-40e6-8e79-7a8bd3f851c3"}}}}, {"uuid": "560d2c90-f0c1-4f09-b2ab-5bdb242b8f86", "name": "", "x": 38.69445247244586, "y": -122.37424590782481, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6fa14b51-a977-4e40-8f9c-28249e576fcf", "name": "p1rdt472", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "560d2c90-f0c1-4f09-b2ab-5bdb242b8f86"}}}}, {"uuid": "5dc257f9-663e-496e-82ab-f02badf92781", "name": "", "x": 38.695584690016524, "y": -122.37575707999054, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "04fc215c-7f3e-45e1-a49c-727b0fcdae93", "name": "p1rdt458-p1rdt468x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5dc257f9-663e-496e-82ab-f02badf92781"}}}}, {"uuid": "c0ce7def-bf8a-4994-9211-1090a6708213", "name": "", "x": 38.69312267817216, "y": -122.37604335226409, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0c5d8237-0351-4eb2-83e6-13975b37bfa7", "name": "p1rdt50", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c0ce7def-bf8a-4994-9211-1090a6708213"}}}}, {"uuid": "a6e05e13-c59b-487a-a856-c53af892ec53", "name": "", "x": 38.69253761865749, "y": -122.37617492032506, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e7305e2b-0a48-4630-8b8e-c3819f1c9cd1", "name": "p1rdt53", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a6e05e13-c59b-487a-a856-c53af892ec53"}}}}, {"uuid": "d0d9e0b2-5201-4618-9538-651dea7a923c", "name": "", "x": 38.69357324297057, "y": -122.37603943809668, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4ea7e0bb-bdc5-429a-8889-2f12c94db72e", "name": "p1rdt59", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d0d9e0b2-5201-4618-9538-651dea7a923c"}}}}, {"uuid": "e2fdec26-5a5b-48a2-a148-888c835ac073", "name": "", "x": 38.69405568995833, "y": -122.37588221381021, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "577124ac-ea2b-4a60-be47-14b0f5db305e", "name": "p1rdt40", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e2fdec26-5a5b-48a2-a148-888c835ac073"}}}}, {"uuid": "49b5489f-b73f-492f-be37-43f9823f28f6", "name": "", "x": 38.69445481567878, "y": -122.37574430437743, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "12fef7fc-57f0-4494-becd-4724b84dbbcb", "name": "p1rdt457", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "49b5489f-b73f-492f-be37-43f9823f28f6"}}}}, {"uuid": "d2981dd6-bb67-4a21-b888-fa072ef2814d", "name": "", "x": 38.69524468972365, "y": -122.37577988845278, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d709af4b-1115-403b-a68d-76c63c93adf2", "name": "p1rdt474", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d2981dd6-bb67-4a21-b888-fa072ef2814d"}}}}, {"uuid": "036ca743-6e5f-4397-b298-e6da7abbbd82", "name": "", "x": 38.695656536068775, "y": -122.3757951768077, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5814195b-dd60-4a1e-9af6-b9b84fa4c0c7", "name": "p1rdt468-p1rdt474x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "036ca743-6e5f-4397-b298-e6da7abbbd82"}}}}, {"uuid": "7de12271-b8bc-4949-9775-db2f3d0fa8b9", "name": "", "x": 38.69416819650434, "y": -122.37332846825741, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f9397c58-45a1-4ec3-bd84-b4cd5b52dc80", "name": "p1rdt65", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7de12271-b8bc-4949-9775-db2f3d0fa8b9"}}}}, {"uuid": "f574c707-7785-4ef9-9cf6-4f890606558b", "name": "", "x": 38.69364252102314, "y": -122.37276961025155, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ab2b6727-4d87-4b00-bd49-ba7a6b1b9ce6", "name": "p1rdt63", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f574c707-7785-4ef9-9cf6-4f890606558b"}}}}, {"uuid": "ddcf1e4b-2864-4c58-9602-0c22fa480875", "name": "", "x": 38.69429429294349, "y": -122.37331586905341, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4ae86125-88c3-44fb-9fe9-1a5d820606f6", "name": "p1rdt467", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ddcf1e4b-2864-4c58-9602-0c22fa480875"}}}}, {"uuid": "df901f95-bfa5-4f1a-be8d-56be09dc1b3a", "name": "", "x": 38.69469140583874, "y": -122.37342739439052, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48179f57-b0b9-491b-b654-81583768923a", "name": "p1rdt469", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "df901f95-bfa5-4f1a-be8d-56be09dc1b3a"}}}}, {"uuid": "956e346e-1e34-4cec-b6f1-259a87f18ad5", "name": "", "x": 38.69542702599285, "y": -122.37386149152691, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a634585d-0c70-428e-a3b2-1ec4717d7878", "name": "p1rdt464", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "956e346e-1e34-4cec-b6f1-259a87f18ad5"}}}}, {"uuid": "09d2e6ee-2f60-4e01-83a5-962fd176bb64", "name": "", "x": 38.69557377117983, "y": -122.37396893690091, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2e5c3d02-1cd2-45e4-90d3-10b135c65f13", "name": "p1rdt480", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "09d2e6ee-2f60-4e01-83a5-962fd176bb64"}}}}, {"uuid": "5a7937d8-a3eb-45f2-b178-6c3eead7e7cc", "name": "", "x": 38.69642974090264, "y": -122.37431272204606, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "76880999-6f79-4fc6-9367-1c419eee26d5", "name": "p1rdt473", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5a7937d8-a3eb-45f2-b178-6c3eead7e7cc"}}}}, {"uuid": "fea57a38-f4cb-464a-aeee-8c88416598f1", "name": "", "x": 38.69676892757635, "y": -122.37432921866969, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d1bb6f93-7aed-47d7-99db-7c17352a42b8", "name": "p1rdt453", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fea57a38-f4cb-464a-aeee-8c88416598f1"}}}}, {"uuid": "7de38676-e68c-41bd-b881-6545360d00a9", "name": "", "x": 38.697042200822686, "y": -122.37424988896967, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d51e6f65-c45c-4f10-a17f-6ef684a0a06c", "name": "p1rdt452", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7de38676-e68c-41bd-b881-6545360d00a9"}}}}, {"uuid": "d1220ca0-5321-4d82-a08a-3738153e2860", "name": "", "x": 38.69788387901549, "y": -122.3749210284041, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b20fa59a-8573-461a-9c4a-0d47e40d2601", "name": "p1rdt466", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1220ca0-5321-4d82-a08a-3738153e2860"}}}}, {"uuid": "c75db6cf-545e-48dc-8ac1-330cef2f7643", "name": "", "x": 38.69827011722288, "y": -122.37584385822461, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "64ba6716-89f9-49a4-9793-ba80ae41bcd0", "name": "p1rdt466-p1rdt478x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c75db6cf-545e-48dc-8ac1-330cef2f7643"}}}}, {"uuid": "715de1e8-65e3-4ad3-9996-d73649cb2471", "name": "", "x": 38.701722794560474, "y": -122.37384904824599, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "12d5c579-0570-44db-a751-8eeb92355af9", "name": "p1rdt459", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "715de1e8-65e3-4ad3-9996-d73649cb2471"}}}}, {"uuid": "a4a0e6c6-1a05-444c-8d95-22a456abb8b6", "name": "", "x": 38.701153728978355, "y": -122.37360100904912, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eed7e6a8-2b4a-4a54-b69a-e3e1a0614213", "name": "p1rdt471", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a4a0e6c6-1a05-444c-8d95-22a456abb8b6"}}}}, {"uuid": "9c8b7067-51d1-4537-b1ae-3e54b168100a", "name": "", "x": 38.702243046289325, "y": -122.3733960017453, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fcfdc5bf-1c87-42e2-8b35-1f7125d3b5ed", "name": "p1rdt462", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9c8b7067-51d1-4537-b1ae-3e54b168100a"}}}}, {"uuid": "f13eb1dc-c712-49aa-af69-41037bc6049a", "name": "", "x": 38.702902444369066, "y": -122.37348707489292, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dfb0d992-ab18-4f73-933e-a01ce73ef3b2", "name": "p1rdt487", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f13eb1dc-c712-49aa-af69-41037bc6049a"}}}}, {"uuid": "76e35c9a-9560-4eeb-8df3-09560a9c278e", "name": "", "x": 38.72548231736972, "y": -122.31263452007998, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4774ed1a-85ec-4ca0-8e9a-3b232588fb0c", "name": "p1rdt16790", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "76e35c9a-9560-4eeb-8df3-09560a9c278e"}}}}, {"uuid": "0265a43f-a1e0-4db0-b8c6-5963dd5ac674", "name": "", "x": 38.7248434734621, "y": -122.31174862017714, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d4bc644c-9875-4846-8b0f-dfa0568de623", "name": "p1rdt16787", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0265a43f-a1e0-4db0-b8c6-5963dd5ac674"}}}}, {"uuid": "20c89e0d-0eeb-4562-be97-b9842e309720", "name": "", "x": 38.741935598212194, "y": -122.27647050486847, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d29266e8-ce67-45bf-93d9-710d4684ce0b", "name": "p1rdt16790-p1rdt16911x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "20c89e0d-0eeb-4562-be97-b9842e309720"}}}}, {"uuid": "7e5d3205-621f-494a-ab6d-fad769918f9e", "name": "", "x": 38.743604391211804, "y": -122.2733738127215, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "725fbd98-74ba-4143-8947-da9fdc209889", "name": "p1rdt16911", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7e5d3205-621f-494a-ab6d-fad769918f9e"}}}}, {"uuid": "42ca79ed-f62f-4ac0-9102-c9659c386bdb", "name": "", "x": 38.70287643040543, "y": -122.37344445127026, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d53ff9fd-2b16-4026-88fa-2c112d4949c5", "name": "p1rdt16790-p1rdt487xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "42ca79ed-f62f-4ac0-9102-c9659c386bdb"}}}}, {"uuid": "c0e3a7e7-c16f-4b7d-a18a-6aab1ae6d4da", "name": "", "x": 38.703325006090246, "y": -122.37234754500905, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a1b5b099-df99-4729-a26d-f0882e93136f", "name": "p1rdt16790-p1rdt487x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c0e3a7e7-c16f-4b7d-a18a-6aab1ae6d4da"}}}}, {"uuid": "21750166-4903-4b4c-ba19-0e6b7f9489e0", "name": "", "x": 38.70318635641241, "y": -122.37390883465856, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b57b8e2b-62c2-49a0-801d-02cab8092ebd", "name": "p1rdt484", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "21750166-4903-4b4c-ba19-0e6b7f9489e0"}}}}, {"uuid": "2b9e9c66-5072-4da7-8003-57c1fa927b48", "name": "", "x": 38.70352176107739, "y": -122.37490290192596, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bd2f4b00-6e8b-4faa-a760-7c28f8d36a36", "name": "p1rdt486", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2b9e9c66-5072-4da7-8003-57c1fa927b48"}}}}, {"uuid": "d8957db5-cbe5-4d00-85fe-945d701e8053", "name": "", "x": 38.7035351825914, "y": -122.37510184014613, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "10c2463d-8563-4737-aa7d-e1195c0af9f6", "name": "p1rdt482", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d8957db5-cbe5-4d00-85fe-945d701e8053"}}}}, {"uuid": "d3f45a56-1323-4e5a-bb45-4854c58e77f0", "name": "", "x": 38.70367069880678, "y": -122.37631203298449, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e4064b6c-40b4-418b-95ab-4f9bb0363b14", "name": "p1rdt482-p1rdt485x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d3f45a56-1323-4e5a-bb45-4854c58e77f0"}}}}, {"uuid": "95d9dc99-1cb5-461e-a945-a57274c2eebd", "name": "", "x": 38.70062992258327, "y": -122.37444862489892, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d1eb09d-dff4-4fa3-b96f-ef59b63d6128", "name": "p1rdt477", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "95d9dc99-1cb5-461e-a945-a57274c2eebd"}}}}, {"uuid": "0a21d1b9-6ab1-49d5-a780-884c93792a4d", "name": "", "x": 38.70017599315202, "y": -122.374449032179, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5421facb-0713-404c-97e9-56669fc762b3", "name": "p1rdt476", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a21d1b9-6ab1-49d5-a780-884c93792a4d"}}}}, {"uuid": "5d69f592-01fb-4253-8b5f-8e5d349e1d8a", "name": "", "x": 38.7012326324604, "y": -122.37424787273476, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "85acd1fb-6da3-432a-9508-855ca991641b", "name": "p1rdt479", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5d69f592-01fb-4253-8b5f-8e5d349e1d8a"}}}}, {"uuid": "5cef3667-c445-4b39-bb1f-8c1ab800b88d", "name": "", "x": 38.70153006625403, "y": -122.37425678080724, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "82459f47-0c6f-4173-8c35-5a9fe5db9713", "name": "p1rdt454", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5cef3667-c445-4b39-bb1f-8c1ab800b88d"}}}}, {"uuid": "c3d04bfb-0722-4c14-b3e2-2a08a319c69e", "name": "", "x": 38.701876062215334, "y": -122.37492077650421, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "183de04a-a665-4112-a912-1df68b61d164", "name": "p1rdt455", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c3d04bfb-0722-4c14-b3e2-2a08a319c69e"}}}}, {"uuid": "98278fc0-28a5-42e6-bb31-86f9b808baa4", "name": "", "x": 38.70221801359906, "y": -122.37545476381091, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "59b616e5-76b8-406c-843f-5c71398af81b", "name": "p1rdt460", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "98278fc0-28a5-42e6-bb31-86f9b808baa4"}}}}, {"uuid": "dea738bd-0034-4241-af54-c69d1a1de21a", "name": "", "x": 38.702478034778096, "y": -122.37458202766794, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "86178159-ccd7-45a3-b711-ac237321d52a", "name": "p1rdt470", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dea738bd-0034-4241-af54-c69d1a1de21a"}}}}, {"uuid": "17dc86f4-06a4-4f36-a0c0-053ed5d6918b", "name": "", "x": 38.702879570888186, "y": -122.37552155877664, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "69b5d686-dae0-44c5-a261-f1a73bcb168e", "name": "p1rdt483", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "17dc86f4-06a4-4f36-a0c0-053ed5d6918b"}}}}, {"uuid": "f3209dfb-0d4c-454f-b128-6d905623f51c", "name": "", "x": 38.703660453271056, "y": -122.37621331185325, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d899b807-b194-4f65-bad5-a39e8bc61906", "name": "p1rdt483-p1rdt485x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f3209dfb-0d4c-454f-b128-6d905623f51c"}}}}, {"uuid": "3cdd14db-f66c-40e6-a154-04d71f132931", "name": "", "x": 38.696234466020165, "y": -122.4029175301028, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "232adbbb-2715-44be-8db5-ee062ebf4e46", "name": "p1rdt279-p1rdt89x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3cdd14db-f66c-40e6-a154-04d71f132931"}}}}, {"uuid": "d36ac9a4-d6a8-48ba-a00f-294724d9c50b", "name": "", "x": 38.6936090734191, "y": -122.40307695118932, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "416118a8-65b7-4d9e-90a2-454f065bfddb", "name": "p1rdt279-p1rdt89xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d36ac9a4-d6a8-48ba-a00f-294724d9c50b"}}}}, {"uuid": "5a37f945-3b6c-4993-8b09-bd86f15e9ca8", "name": "", "x": 38.691921020060555, "y": -122.4037273791967, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ac4ad276-90cb-48c0-bfd0-1f2aa0233ce2", "name": "p1rdt89", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5a37f945-3b6c-4993-8b09-bd86f15e9ca8"}}}}, {"uuid": "1d7465a0-15cf-41d5-961d-c03eaf8bcc3c", "name": "", "x": 38.71273376728585, "y": -122.26236860525948, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d50d3e76-470b-47c2-ada2-da944962b322", "name": "p1rdt16427", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d7465a0-15cf-41d5-961d-c03eaf8bcc3c"}}}}, {"uuid": "832689e9-558f-4425-9e83-1b5db67ee44f", "name": "", "x": 38.713290303421466, "y": -122.26149228450026, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "18e3da78-83fc-4b8e-9d45-41adb9b753ad", "name": "p1rdt16424", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "832689e9-558f-4425-9e83-1b5db67ee44f"}}}}, {"uuid": "7fec0620-591f-4608-b812-80cf87d91f9d", "name": "", "x": 38.69570787792313, "y": -122.29851285731566, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8e35a4f7-19c1-4f59-9adc-b267f6088264", "name": "p1rdt16847", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7fec0620-591f-4608-b812-80cf87d91f9d"}}}}, {"uuid": "6704537b-9d53-40b6-b9e8-e67e3d651524", "name": "", "x": 38.71191996461427, "y": -122.26381070914681, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a6382a2-8c21-4cb4-a39b-3f1ac62cc705", "name": "p1rdt16427-p1rdt16847x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6704537b-9d53-40b6-b9e8-e67e3d651524"}}}}, {"uuid": "cc64522b-669a-4319-93fb-4f32f3956d1b", "name": "", "x": 38.68960809733261, "y": -122.30930023811142, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "61d5dee2-30f8-434d-8c03-76bccff72549", "name": "p1rdt16404", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc64522b-669a-4319-93fb-4f32f3956d1b"}}}}, {"uuid": "27628ce8-d3dd-4b33-8235-963ca36f778a", "name": "", "x": 38.69038163570117, "y": -122.31517993828531, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c5b51836-1807-4fab-b877-94a62021569f", "name": "p1rdt16394", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "27628ce8-d3dd-4b33-8235-963ca36f778a"}}}}, {"uuid": "420ccfac-7dbd-4510-83b6-2bea0e849955", "name": "", "x": 38.684262624044464, "y": -122.31767924836156, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b5a9e0f5-d824-4a76-a4f0-88aab072280e", "name": "p1rdt16603", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "420ccfac-7dbd-4510-83b6-2bea0e849955"}}}}, {"uuid": "88bd7eea-2f21-4a0d-879d-c3a70ed66def", "name": "", "x": 38.68314419705685, "y": -122.31905803173453, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "98a946e8-3c8a-49ec-be8a-5610c7fc596c", "name": "p1rdt16604", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "88bd7eea-2f21-4a0d-879d-c3a70ed66def"}}}}, {"uuid": "4fd2ad5d-d4e0-480c-a014-3cc3aa2fa98d", "name": "", "x": 38.68864067156756, "y": -122.34840259338564, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ef71bd7-4c82-4296-a6ac-64516ffe96c5", "name": "p1rdt16604-p1rdt257x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4fd2ad5d-d4e0-480c-a014-3cc3aa2fa98d"}}}}, {"uuid": "f00cd8ba-b7f8-491a-b665-015a9277eadf", "name": "", "x": 38.68800685251441, "y": -122.34473682420163, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "282d8a89-8b14-476b-9e55-b310d8b9396d", "name": "p1rdt16604-p1rdt257x_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f00cd8ba-b7f8-491a-b665-015a9277eadf"}}}}, {"uuid": "1e961363-685e-4320-a9c9-c6a11ef0dc32", "name": "", "x": 38.68510682934324, "y": -122.35589682226349, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dcb27aab-e828-41a6-ad98-d197897a1a69", "name": "p1rdt209", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1e961363-685e-4320-a9c9-c6a11ef0dc32"}}}}, {"uuid": "a0cc6f33-f3de-4070-97bb-48c0aa09dfbf", "name": "", "x": 38.688681896745614, "y": -122.34841487443683, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3fb307f7-3690-4931-999a-4daab4d8c9e5", "name": "p1rdt257", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a0cc6f33-f3de-4070-97bb-48c0aa09dfbf"}}}}, {"uuid": "c26732ea-f986-41bc-95b2-b21b77a33f93", "name": "", "x": 38.68463781682152, "y": -122.35798033063733, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5d782d5e-3960-415c-9e33-6742777a5a0a", "name": "p1rdt210", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c26732ea-f986-41bc-95b2-b21b77a33f93"}}}}, {"uuid": "49ded750-7593-4589-9e1f-5c12c16bb481", "name": "", "x": 38.683540995258845, "y": -122.35679446809597, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b9401940-26a4-40f3-9b9a-5231a5c4e171", "name": "p1rdt211", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "49ded750-7593-4589-9e1f-5c12c16bb481"}}}}, {"uuid": "365a5752-e72f-4dc2-b314-1e000a8741e4", "name": "", "x": 38.68281023348963, "y": -122.35409734055312, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b89bfea1-97cd-41f7-af59-9602a3fc6c06", "name": "p1rdt278", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "365a5752-e72f-4dc2-b314-1e000a8741e4"}}}}, {"uuid": "8d37cf05-96a3-4d8e-bc5c-a40817f491c0", "name": "", "x": 38.68941008309863, "y": -122.37010832848992, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d1be5e34-ad5e-4c78-8067-8e0194c661a4", "name": "p1rdt210-p1rdt44x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8d37cf05-96a3-4d8e-bc5c-a40817f491c0"}}}}, {"uuid": "d48bab44-c136-4b4b-b5ef-2edb555ca1aa", "name": "", "x": 38.689335231948924, "y": -122.37012765218032, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f0b5743e-c3fd-49c7-879e-9be7d00c480f", "name": "p1rdt259-p1rdt44x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d48bab44-c136-4b4b-b5ef-2edb555ca1aa"}}}}, {"uuid": "d3241610-de63-4356-9931-09d85e05faa4", "name": "", "x": 38.68475989424937, "y": -122.36996130497471, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33a0a070-9cce-4a82-bd22-24a65f02ef97", "name": "p1rdt259", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d3241610-de63-4356-9931-09d85e05faa4"}}}}, {"uuid": "6861d9ef-ae9d-4bcd-b45d-e3cea1fee6da", "name": "", "x": 38.69119253254578, "y": -122.3723691075126, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7728581d-66fc-4e7e-b2b0-85fa02c90523", "name": "p1rdt43", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6861d9ef-ae9d-4bcd-b45d-e3cea1fee6da"}}}}, {"uuid": "99953f4d-982e-4c24-b529-2f7f64d2139a", "name": "", "x": 38.69217068541305, "y": -122.3732804512017, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1ea0531d-530c-4088-86a1-3de96a8938ea", "name": "p1rdt47", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "99953f4d-982e-4c24-b529-2f7f64d2139a"}}}}, {"uuid": "b9bda6ac-99c6-477c-960d-36334462a180", "name": "", "x": 38.692501666976284, "y": -122.37176768850954, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1667a8c6-aeb4-4f22-97b8-62ffefcc12a4", "name": "p1rdt48", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b9bda6ac-99c6-477c-960d-36334462a180"}}}}, {"uuid": "6fa6d556-40b3-48e9-9dd4-53c85726e76f", "name": "", "x": 38.69243929619441, "y": -122.37127733774665, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4f5cef5c-bcaf-4cd9-afbb-a18bd14dfcd4", "name": "p1rdt51", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6fa6d556-40b3-48e9-9dd4-53c85726e76f"}}}}, {"uuid": "a02913b0-c109-4683-9794-a5abb4af1cd6", "name": "", "x": 38.69084016635201, "y": -122.37219971004839, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d99e903-3536-4a73-b0d5-ca11f5af6e32", "name": "p1rdt60", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a02913b0-c109-4683-9794-a5abb4af1cd6"}}}}, {"uuid": "b593050b-e132-4544-810f-e168f484e82a", "name": "", "x": 38.69044403976456, "y": -122.37227216228393, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a4ccf80-2611-4089-9353-439809aa7854", "name": "p1rdt58", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b593050b-e132-4544-810f-e168f484e82a"}}}}, {"uuid": "faf45571-2233-4e14-8dbd-a4cb9bb93984", "name": "", "x": 38.690014841841176, "y": -122.3723741213489, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7238345a-1fc7-4f3f-bc8b-88cf7582c75c", "name": "p1rdt58-p1rdt69x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "faf45571-2233-4e14-8dbd-a4cb9bb93984"}}}}, {"uuid": "cb7173bb-4199-4353-9284-a0bc9e239ac0", "name": "", "x": 38.691521445820555, "y": -122.37639464686723, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bcea1fd6-3c51-48af-8528-d3d7bc8e4f01", "name": "p1rdt71", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb7173bb-4199-4353-9284-a0bc9e239ac0"}}}}, {"uuid": "6063cb06-32cd-4338-85e5-260df69cd2de", "name": "", "x": 38.69124250818054, "y": -122.37559619861726, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "744725a8-af2a-47cf-948f-9d453a932e32", "name": "p1rdt61", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6063cb06-32cd-4338-85e5-260df69cd2de"}}}}, {"uuid": "ddcdbfed-3171-4fa1-b47a-20f5a01c95ab", "name": "", "x": 38.69156944308755, "y": -122.37634466226288, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eab6b8c5-ee7a-4779-b5eb-5205dbe5253c", "name": "p1rdt150-p1rdt71x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ddcdbfed-3171-4fa1-b47a-20f5a01c95ab"}}}}, {"uuid": "91db4e45-8d24-4b88-9548-edc1fcce5953", "name": "", "x": 38.69156345018649, "y": -122.37716473257039, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf5b238a-832f-4f45-8a36-2248549e1723", "name": "p1rdt150-p1rdt71xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "91db4e45-8d24-4b88-9548-edc1fcce5953"}}}}, {"uuid": "ef35acf6-032c-4963-a01f-2230eacca63a", "name": "", "x": 38.686995650033, "y": -122.45197514226767, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0f2a0358-b10d-4b62-8f8d-9a5054fae87d", "name": "p1rdt376", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef35acf6-032c-4963-a01f-2230eacca63a"}}}}, {"uuid": "8f3f93e7-1578-47b2-86b9-794346f706ac", "name": "", "x": 38.68750853010239, "y": -122.45098420292979, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d425a00d-c0e9-465d-9d9b-af4d64708fba", "name": "p1rdt374", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8f3f93e7-1578-47b2-86b9-794346f706ac"}}}}, {"uuid": "19d36e6c-2460-47b8-9e33-b4dcbcb80539", "name": "", "x": 38.68515597552901, "y": -122.45198911454673, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0de112ae-d04a-4673-98af-0699e4890429", "name": "p1rdt335-p1rdt376x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "19d36e6c-2460-47b8-9e33-b4dcbcb80539"}}}}, {"uuid": "af233a4c-7d45-41d9-a62c-72de519562f2", "name": "", "x": 38.67357675550989, "y": -122.4699912914106, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "101c6236-a474-45c8-b065-f5fa045b1107", "name": "p1rdt415", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "af233a4c-7d45-41d9-a62c-72de519562f2"}}}}, {"uuid": "9f19600a-edcd-46ba-ae35-6e1056793679", "name": "", "x": 38.67350163747049, "y": -122.4708045160677, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "71fa675e-bc20-46f7-b6f1-c88962f9f3cb", "name": "p1rdt417", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9f19600a-edcd-46ba-ae35-6e1056793679"}}}}, {"uuid": "bea72cbb-7842-4b45-817f-7fb1e09441f5", "name": "", "x": 38.67293062003175, "y": -122.46738711812904, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "19116f3c-29ae-4819-ba72-dd0f8afa5078", "name": "p1rdt415-p1rdt419x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bea72cbb-7842-4b45-817f-7fb1e09441f5"}}}}, {"uuid": "8d8841bf-aa27-4b28-ac54-de67f23e7732", "name": "", "x": 38.665494529835904, "y": -122.46043005782059, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9100fbd6-863e-48b2-94ed-aca1ef0947bd", "name": "p1rdt5098", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8d8841bf-aa27-4b28-ac54-de67f23e7732"}}}}, {"uuid": "5813a119-def8-4d45-b4bb-5d832ab51878", "name": "", "x": 38.66895816218114, "y": -122.45865330515163, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5258d4de-be4c-478d-b752-7f4efb0af0a5", "name": "p1rdt180", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5813a119-def8-4d45-b4bb-5d832ab51878"}}}}, {"uuid": "8c5463e5-55d2-48d9-b10f-67b2ccace9cd", "name": "", "x": 38.66514031344027, "y": -122.44753960527862, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9f273a36-c30d-4962-81f4-26f8d20e1cf4", "name": "p1rdt6584", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8c5463e5-55d2-48d9-b10f-67b2ccace9cd"}}}}, {"uuid": "71bd4c9c-02a9-484c-aca4-ac5ffddf68dd", "name": "", "x": 38.66464311110499, "y": -122.44791919098567, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e257530-1fe2-410b-83a1-57789e6ddeda", "name": "p1rdt6578", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "71bd4c9c-02a9-484c-aca4-ac5ffddf68dd"}}}}, {"uuid": "6a0a739a-8c43-452d-ac2c-72a7a7e2d4d6", "name": "", "x": 38.66574098458345, "y": -122.44687980665202, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1648fe3-a7f9-47aa-b168-d2b56cf220e7", "name": "p1rdt6588", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a0a739a-8c43-452d-ac2c-72a7a7e2d4d6"}}}}, {"uuid": "c3aa5e75-c547-4302-a29e-0a307e7e49c0", "name": "", "x": 38.66451724050103, "y": -122.44667705028046, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1d0a85a-62dc-46d2-bae1-d43d07743a34", "name": "p1rdt6591", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c3aa5e75-c547-4302-a29e-0a307e7e49c0"}}}}, {"uuid": "9e340273-38a6-48fe-869c-873f661a3243", "name": "", "x": 38.664682198133455, "y": -122.446168239027, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5291ea2b-6990-407b-b8d4-d6868bf37310", "name": "p1rdt6590", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9e340273-38a6-48fe-869c-873f661a3243"}}}}, {"uuid": "48f38dca-aa76-4927-9b84-65ffec914a19", "name": "", "x": 38.666084365577824, "y": -122.44838916371525, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d77add8e-ba22-4b44-9c0b-0bddc251a573", "name": "p1rdt6587", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "48f38dca-aa76-4927-9b84-65ffec914a19"}}}}, {"uuid": "70b56e2a-5e1c-4c12-a230-51d8f4fdc039", "name": "", "x": 38.6658846543716, "y": -122.44807809992015, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b918e583-d163-4136-aaf8-62085c7b0c17", "name": "p1rdt6584-p1rdt6587x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "70b56e2a-5e1c-4c12-a230-51d8f4fdc039"}}}}, {"uuid": "42b72520-be1d-4c12-a534-0a09bcbf8c0b", "name": "", "x": 38.66666084985903, "y": -122.45155897573034, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "68298e92-fca3-44e9-9271-f79be47c9c63", "name": "p1rdt6580", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "42b72520-be1d-4c12-a534-0a09bcbf8c0b"}}}}, {"uuid": "9700ef27-7399-42c3-a41c-ba76f3a5ba0d", "name": "", "x": 38.66481336487895, "y": -122.46776680294279, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cb3d775d-8d92-498b-989c-387278ec8e9e", "name": "p1rdt5098-p1rdt8169x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9700ef27-7399-42c3-a41c-ba76f3a5ba0d"}}}}, {"uuid": "f5375e9b-fd09-4d67-abb9-558b3cc8346c", "name": "", "x": 38.66954985597873, "y": -122.47289306798201, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16b7f1e9-3405-4c5f-96c7-d5c08d791907", "name": "p1rdt418", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5375e9b-fd09-4d67-abb9-558b3cc8346c"}}}}, {"uuid": "0dd337d1-0ca4-48d8-8854-be2ef5efcfc5", "name": "", "x": 38.669198863842276, "y": -122.47439167095719, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3034e62-dd19-4ecb-bb39-6d0566e3a2ef", "name": "p1rdt414", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0dd337d1-0ca4-48d8-8854-be2ef5efcfc5"}}}}, {"uuid": "451ee1d6-69bb-4c5a-add8-b26af72700e1", "name": "", "x": 38.669612414212985, "y": -122.47279835298632, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ba78164d-d6ae-413b-8d24-067d8d38b28f", "name": "p1rdt416-p1rdt418x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "451ee1d6-69bb-4c5a-add8-b26af72700e1"}}}}, {"uuid": "13226904-e2e9-4814-b434-26821b104bc7", "name": "", "x": 38.671409309606254, "y": -122.47045206876079, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d16d5f5e-a376-4e39-a845-d2cde8800da3", "name": "p1rdt416", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "13226904-e2e9-4814-b434-26821b104bc7"}}}}, {"uuid": "48de8757-efa8-483a-8c9c-5c4f6109a371", "name": "", "x": 38.666461847991535, "y": -122.47096331177207, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1e3d41a7-06a4-460b-aa6c-3a60c8d2de10", "name": "p1rdt8201", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "48de8757-efa8-483a-8c9c-5c4f6109a371"}}}}, {"uuid": "ab0cc721-fe40-47c1-af8d-c996d017fdd8", "name": "", "x": 38.66526928202583, "y": -122.47027798516622, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "63928702-c44a-4e83-9cca-7ce77bdbd2b3", "name": "p1rdt8180-p1rdt8201x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ab0cc721-fe40-47c1-af8d-c996d017fdd8"}}}}, {"uuid": "22822696-ace4-4b6e-9db9-cf01859dd5b7", "name": "", "x": 38.658100245225164, "y": -122.48194171749711, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "246ad62e-5a10-4031-94e7-1732f58f1da9", "name": "p1rdt9055", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "22822696-ace4-4b6e-9db9-cf01859dd5b7"}}}}, {"uuid": "42866221-5545-4352-b430-fcf9cba1b4d0", "name": "", "x": 38.658393900938755, "y": -122.48112128391094, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cd9ea283-dbd2-4f38-b298-86a191c99bd2", "name": "p1rdt6265-p1rdt9055x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "42866221-5545-4352-b430-fcf9cba1b4d0"}}}}, {"uuid": "e03f9558-f8a9-4c77-88dd-fd9becc4fa78", "name": "", "x": 38.66056852061021, "y": -122.48035453306898, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2d316c13-77c1-4412-baf9-801f7e5ae407", "name": "p1rdt6265", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e03f9558-f8a9-4c77-88dd-fd9becc4fa78"}}}}, {"uuid": "60ff6017-72bc-4e90-890f-a061fd92703b", "name": "", "x": 38.65517194896592, "y": -122.48092661777345, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "30adfcd5-405b-47ea-be54-55c5a47c835f", "name": "p1rdt5560-p1rdt9055x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "60ff6017-72bc-4e90-890f-a061fd92703b"}}}}, {"uuid": "486eb953-e908-4a2e-a027-ef91dd99a6d8", "name": "", "x": 38.65725844991055, "y": -122.4811294760667, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "708f65d6-b869-4d26-930d-0e669caf4ffb", "name": "p1rdt5560-p1rdt9055xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "486eb953-e908-4a2e-a027-ef91dd99a6d8"}}}}, {"uuid": "28380f22-c0fa-475d-b399-b1cf74e2d018", "name": "", "x": 38.65230276217263, "y": -122.47461858577147, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d2ea25e-3d48-4b1d-9e52-768752de2e09", "name": "p1rdt7737", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "28380f22-c0fa-475d-b399-b1cf74e2d018"}}}}, {"uuid": "8f2f7c97-e09b-479b-837d-464111202a96", "name": "", "x": 38.65261575836355, "y": -122.4740602281008, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d142315b-a247-4a4d-a178-73e3c150a188", "name": "p1rdt7753", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8f2f7c97-e09b-479b-837d-464111202a96"}}}}, {"uuid": "5e5b7087-e9b0-48be-b147-19fd7f3264c1", "name": "", "x": 38.65184325416811, "y": -122.47515027973938, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4413ca7f-fdd1-484e-a0ba-3ff2447ebfef", "name": "p1rdt7791", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5e5b7087-e9b0-48be-b147-19fd7f3264c1"}}}}, {"uuid": "5d9e1eac-53fe-4947-b515-8daa7226ff69", "name": "", "x": 38.65207704845808, "y": -122.47515639717327, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0946738d-95de-4ad6-9d56-c043cb64c0e4", "name": "p1rdt7737-p1rdt7791x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5d9e1eac-53fe-4947-b515-8daa7226ff69"}}}}, {"uuid": "2826c794-b792-4ddc-8cc3-299a0c520ed3", "name": "", "x": 38.650951110512295, "y": -122.47644062493562, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "02351140-e632-49e2-83e4-7e5bc1c8856a", "name": "p1rdt7286", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2826c794-b792-4ddc-8cc3-299a0c520ed3"}}}}, {"uuid": "bd1fc43e-5a7b-4ff3-a94b-13041d21829c", "name": "", "x": 38.650648984972726, "y": -122.4768636646543, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8f8375b7-7bdd-409c-9fa1-5c13bd233364", "name": "p1rdt7289", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bd1fc43e-5a7b-4ff3-a94b-13041d21829c"}}}}, {"uuid": "1021a436-70ff-46d2-a2b1-36a6647e3118", "name": "", "x": 38.64944561704761, "y": -122.4757921819993, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4afa9bec-d8da-4449-ab96-9f875bae3c33", "name": "p1rdt7293", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1021a436-70ff-46d2-a2b1-36a6647e3118"}}}}, {"uuid": "69c7c6c7-1a98-4695-8108-a198c0b20ae5", "name": "", "x": 38.65290986333587, "y": -122.48317621935037, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0c83b6ee-20fc-4ca0-a778-44735283afd5", "name": "p1rdt5568", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "69c7c6c7-1a98-4695-8108-a198c0b20ae5"}}}}, {"uuid": "4426b99d-b785-4e5c-8972-5c972cdc1537", "name": "", "x": 38.653647469597004, "y": -122.48368389304464, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c8aa126c-9b2b-4ae0-a4fc-36d4201762a0", "name": "p1rdt5551-p1rdt5568xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4426b99d-b785-4e5c-8972-5c972cdc1537"}}}}, {"uuid": "ead5b8ed-3484-430c-a8ae-dc48d05070f0", "name": "", "x": 38.653032242675096, "y": -122.48324009208464, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "65eb08cf-6350-410a-88c2-3b318d3a262a", "name": "p1rdt5551-p1rdt5568xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ead5b8ed-3484-430c-a8ae-dc48d05070f0"}}}}, {"uuid": "3e1daa0b-ddcc-4ad5-9f93-673e981a9174", "name": "", "x": 38.652900682241246, "y": -122.48322892310364, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "64aba8d5-1dd3-4741-a8ba-26801e275ba8", "name": "p1rdt5551-p1rdt5568xxxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e1daa0b-ddcc-4ad5-9f93-673e981a9174"}}}}, {"uuid": "231d6b41-e4d1-42bc-9618-d294db1cb3a1", "name": "", "x": 38.65348179379366, "y": -122.4842621130032, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0c49b671-0b2b-43c9-bcb5-21c7b7e716ce", "name": "p1rdt5548-p1rdt5577xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "231d6b41-e4d1-42bc-9618-d294db1cb3a1"}}}}, {"uuid": "ea0b67e7-491e-44da-a05f-d51bc1dc6c07", "name": "", "x": 38.652151086540165, "y": -122.48369686652708, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fead5749-3ba7-4ead-a604-e8adbd18f8c2", "name": "p1rdt5548-p1rdt5577xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea0b67e7-491e-44da-a05f-d51bc1dc6c07"}}}}, {"uuid": "202ca4fc-f7c0-4c03-85d6-93e58cf5c199", "name": "", "x": 38.67222953111598, "y": -122.47625831645591, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c51ccb17-eed6-4ce0-b839-e7b26001fe3e", "name": "p1rdt304", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "202ca4fc-f7c0-4c03-85d6-93e58cf5c199"}}}}, {"uuid": "cf4d842f-4898-4504-99b0-7952f53b6158", "name": "", "x": 38.67878840609695, "y": -122.47525103045935, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "08e378d4-4ca6-4c9e-93fa-36ff87a3cf0f", "name": "p1rdt182", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cf4d842f-4898-4504-99b0-7952f53b6158"}}}}, {"uuid": "78af3e58-f400-406c-bd8e-efa3077f8637", "name": "", "x": 38.67077336251232, "y": -122.47582856074445, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7b936973-54dc-41e7-a413-8932c31f0793", "name": "p1rdt305", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "78af3e58-f400-406c-bd8e-efa3077f8637"}}}}, {"uuid": "8019fa58-ddff-4d58-9d54-6ba68f47b6af", "name": "", "x": 38.670527094141356, "y": -122.4798175179331, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9672c49b-8316-4907-b204-7505483210b0", "name": "p1rdt303", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8019fa58-ddff-4d58-9d54-6ba68f47b6af"}}}}, {"uuid": "d4d6f94f-f802-4308-9407-6b6546edf927", "name": "", "x": 38.66807769283756, "y": -122.48429523464395, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3ad84ef4-4dcc-42f7-99ed-b8d21cebc465", "name": "p1rdt177", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d4d6f94f-f802-4308-9407-6b6546edf927"}}}}, {"uuid": "4d1b6692-00b6-48e4-badf-57286e495511", "name": "", "x": 38.67120072595356, "y": -122.49044397744001, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "57a78c71-e5a8-4dfd-8359-e368b7b198fa", "name": "p1rdt306", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d1b6692-00b6-48e4-badf-57286e495511"}}}}, {"uuid": "ceeea650-e1b4-4e66-90cd-57fbde5fae70", "name": "", "x": 38.68186286213555, "y": -122.49395729632428, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6912a245-ac1c-4ddd-b021-3bc35cbbe2c5", "name": "p1rdt178", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ceeea650-e1b4-4e66-90cd-57fbde5fae70"}}}}, {"uuid": "365d0a90-7e2b-4a3a-b6cb-9ec8a40f3ee9", "name": "", "x": 38.65563774049388, "y": -122.48693753355442, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3f91816-7c3f-4fc7-98a5-6dee55e52e9f", "name": "p1rdt8105", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "365d0a90-7e2b-4a3a-b6cb-9ec8a40f3ee9"}}}}, {"uuid": "5275819a-01e1-4e57-8757-365b836edff4", "name": "", "x": 38.65332887399879, "y": -122.4877199764791, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f2c69fef-4afb-4bb3-9828-096b812de54a", "name": "p1rdt8111", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5275819a-01e1-4e57-8757-365b836edff4"}}}}, {"uuid": "d6c9dab0-2688-471e-9207-5a682545447e", "name": "", "x": 38.65397853262116, "y": -122.48734763535352, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "37229b7c-80a2-4d01-af6a-818bdfcc1f54", "name": "p1rdt8105-p1rdt8111x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d6c9dab0-2688-471e-9207-5a682545447e"}}}}, {"uuid": "0cd3484e-7c70-4cad-97ef-8a3cfa794239", "name": "", "x": 38.653298743960605, "y": -122.48786735210962, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fc34073b-94f6-4c75-8144-8f624bac9cc7", "name": "p1rdt8146", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0cd3484e-7c70-4cad-97ef-8a3cfa794239"}}}}, {"uuid": "10dac104-0d6e-41d9-8fc3-8f17a40b3a12", "name": "", "x": 38.65338804911886, "y": -122.48767001324168, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9929e0d4-3e33-4f5f-b718-6a629cc52242", "name": "p1rdt8111-p1rdt8138xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10dac104-0d6e-41d9-8fc3-8f17a40b3a12"}}}}, {"uuid": "0e5fd983-d874-4f22-ad29-f0f286977194", "name": "", "x": 38.65220693629279, "y": -122.48673933307626, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3a54311-da27-45d7-95c3-eee07761fbe4", "name": "p1rdt8111-p1rdt8138x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0e5fd983-d874-4f22-ad29-f0f286977194"}}}}, {"uuid": "fa457226-617f-4a99-b897-6225df98cda6", "name": "", "x": 38.706834415392834, "y": -122.42490821272983, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b801037a-e1bb-4c5c-8d18-ed285c8c1d3b", "name": "p1rdt251", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa457226-617f-4a99-b897-6225df98cda6"}}}}, {"uuid": "e5389bd2-8ce8-4204-97bd-aee05bb56864", "name": "", "x": 38.70723865207442, "y": -122.42480038439254, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "69b2ee46-ab5f-48c8-a26b-170ed2b57fcb", "name": "p1rdt252", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e5389bd2-8ce8-4204-97bd-aee05bb56864"}}}}, {"uuid": "39cabe12-2278-40ba-9afa-b474d3d17fae", "name": "", "x": 38.70153411123505, "y": -122.42253878409483, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3dfe357-889d-42e0-a59a-821c9f843456", "name": "p1rdt446", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "39cabe12-2278-40ba-9afa-b474d3d17fae"}}}}, {"uuid": "13201431-68c1-4d67-ab30-848923d4ecd2", "name": "", "x": 38.696509390287886, "y": -122.37572644565952, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2cf3136f-6dbe-4ed7-b9cb-e9f73b191f76", "name": "p1rdt481", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "13201431-68c1-4d67-ab30-848923d4ecd2"}}}}, {"uuid": "bb919fde-343d-4af8-b649-1a441fcbe691", "name": "", "x": 38.69562927890001, "y": -122.37574956469108, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a180b972-cf0e-4a2e-9bcf-a0ad90bb3d83", "name": "p1rdt468", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bb919fde-343d-4af8-b649-1a441fcbe691"}}}}, {"uuid": "116b3e5d-3798-43ce-a998-c53f4ba9e37b", "name": "", "x": 38.696842869414894, "y": -122.37573504621221, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c39140c6-8892-480a-81b9-738c67ed1591", "name": "p1rdt475", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "116b3e5d-3798-43ce-a998-c53f4ba9e37b"}}}}, {"uuid": "ee055b10-cabe-4d1d-8c63-0991b1e0c92a", "name": "", "x": 38.697374719659294, "y": -122.37576492139411, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fc35f44e-d8d9-41d0-b014-caa3d8d7a91e", "name": "p1rdt461", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ee055b10-cabe-4d1d-8c63-0991b1e0c92a"}}}}, {"uuid": "ec600ace-eeeb-4966-b6d6-37f79e672b78", "name": "", "x": 38.69825572660699, "y": -122.37579303954152, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2eba354c-f4bf-4c49-a8ad-998ab9489e5a", "name": "p1rdt478", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ec600ace-eeeb-4966-b6d6-37f79e672b78"}}}}, {"uuid": "84847f25-821b-400e-a799-cd3cf8fa9ba5", "name": "", "x": 38.69843582959593, "y": -122.37576847475998, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a94f7afe-e8b0-4b24-8196-6b05e98c3830", "name": "p1rdt465", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "84847f25-821b-400e-a799-cd3cf8fa9ba5"}}}}, {"uuid": "b3af6a2d-b395-43bc-805c-a33d0eac214e", "name": "", "x": 38.699753883698804, "y": -122.37577873918647, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0fa474a3-1d6b-454b-9170-6a8d13789c43", "name": "p1rdt488", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b3af6a2d-b395-43bc-805c-a33d0eac214e"}}}}, {"uuid": "bea7aa80-5487-4162-a59d-41c01b796663", "name": "", "x": 38.699988606794975, "y": -122.37585719796019, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7637cfdb-6a14-4313-95d4-e25beba178f3", "name": "p1rdt463", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bea7aa80-5487-4162-a59d-41c01b796663"}}}}, {"uuid": "d0ae0a33-8d9d-4e46-baff-4744dbc33df5", "name": "", "x": 38.701244304283534, "y": -122.3764327877571, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7627cbc6-c54a-432b-8cba-59e448f6d45a", "name": "p1rdt82", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d0ae0a33-8d9d-4e46-baff-4744dbc33df5"}}}}, {"uuid": "feb8f7d0-ddd9-49a4-9035-25a0f5fa1802", "name": "", "x": 38.701568593856685, "y": -122.37703593173678, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "36bfd1f1-80ca-4b7d-a68b-9aa77ceff96e", "name": "p1rdt78", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "feb8f7d0-ddd9-49a4-9035-25a0f5fa1802"}}}}, {"uuid": "61ff3521-9b61-4365-b8d2-19db719ca287", "name": "", "x": 38.70158095287149, "y": -122.37746615460954, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6fc415bc-f457-4e9f-bbd4-783a71b67ad6", "name": "p1rdt85", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "61ff3521-9b61-4365-b8d2-19db719ca287"}}}}, {"uuid": "8dc7b52a-7147-455e-9b0a-451e50e06055", "name": "", "x": 38.701575510504455, "y": -122.37770642721351, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "063e25be-2abb-49ae-b459-ddd08ba93bb3", "name": "p1rdt81", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8dc7b52a-7147-455e-9b0a-451e50e06055"}}}}, {"uuid": "f44e3248-9cf9-47bd-87c6-7258b7bcf930", "name": "", "x": 38.701531800163046, "y": -122.37795980901173, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b32c9763-ddff-435b-a28c-8f65111c6cb2", "name": "p1rdt79", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f44e3248-9cf9-47bd-87c6-7258b7bcf930"}}}}, {"uuid": "8e69fd51-7eb9-4fd3-b2d6-8a48a810d9a3", "name": "", "x": 38.70139571168677, "y": -122.37841744526864, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dfbb212a-9882-4468-86ac-578c93fde1d8", "name": "p1rdt76", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8e69fd51-7eb9-4fd3-b2d6-8a48a810d9a3"}}}}, {"uuid": "28739721-e132-4b04-86a9-56f6ea3da7da", "name": "", "x": 38.70130561638834, "y": -122.3796880720142, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7c543753-fa26-41df-b7a6-3664395c0d45", "name": "p1rdt31", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "28739721-e132-4b04-86a9-56f6ea3da7da"}}}}, {"uuid": "62463952-0717-41bf-9839-1f1550b7af30", "name": "", "x": 38.70185707821067, "y": -122.38044898464344, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e8dcdfef-b40e-4f1c-9b7c-e84846f68c5a", "name": "p1rdt36", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "62463952-0717-41bf-9839-1f1550b7af30"}}}}, {"uuid": "9101c6b5-0c1a-49cf-a987-2070793803fa", "name": "", "x": 38.702744402653344, "y": -122.38060588011899, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "834e959c-8ee6-4fff-b1fc-54c20fc0f20b", "name": "p1rdt32", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9101c6b5-0c1a-49cf-a987-2070793803fa"}}}}, {"uuid": "f4a0f3e7-a651-456a-8d40-60652fb7afc2", "name": "", "x": 38.70315433826527, "y": -122.38036878848187, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "80331f15-8b31-454c-a289-49cb79923252", "name": "p1rdt234", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f4a0f3e7-a651-456a-8d40-60652fb7afc2"}}}}, {"uuid": "2d354866-5878-4547-971d-7695b52967f8", "name": "", "x": 38.70342202813448, "y": -122.37754091771487, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8f5ed5d5-93fc-4f3c-a78b-df7019863b67", "name": "p1rdt233", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2d354866-5878-4547-971d-7695b52967f8"}}}}, {"uuid": "ff295c7d-9e68-4562-91ff-1c05b39881db", "name": "", "x": 38.70364344183274, "y": -122.37626641561926, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "445f61a4-8045-4558-a3c1-bb44336737ec", "name": "p1rdt485", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ff295c7d-9e68-4562-91ff-1c05b39881db"}}}}, {"uuid": "5593c229-b3c9-4d0d-bc4f-0be1328a3af8", "name": "", "x": 38.70340510620564, "y": -122.37837704887761, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "190d6c51-94b6-462e-8fee-cce57f1ab66d", "name": "p1rdt236", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5593c229-b3c9-4d0d-bc4f-0be1328a3af8"}}}}, {"uuid": "673128da-caab-4282-9357-c1d62f2c2ece", "name": "", "x": 38.70289903823247, "y": -122.38150952694326, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "14b85850-d83e-4a5e-83c3-ccb485bb85aa", "name": "p1rdt235", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "673128da-caab-4282-9357-c1d62f2c2ece"}}}}, {"uuid": "a374df4b-0d29-44b7-9bac-64b8948c031e", "name": "", "x": 38.70241528605291, "y": -122.38205420706528, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4fa95a19-0e0a-49b3-bb86-7103fbaa4110", "name": "p1rdt30", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a374df4b-0d29-44b7-9bac-64b8948c031e"}}}}, {"uuid": "27886ea0-4c87-411a-b113-73a096f62fda", "name": "", "x": 38.70180761889256, "y": -122.38302545203672, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "edc22f66-e919-448e-b990-76033c281d43", "name": "p1rdt35", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "27886ea0-4c87-411a-b113-73a096f62fda"}}}}, {"uuid": "236076ef-b7c1-4fb9-8263-b3a045928901", "name": "", "x": 38.70163145569769, "y": -122.3837974760483, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1e9f4b13-5fb5-46b2-9258-83582d47d61a", "name": "p1rdt84", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "236076ef-b7c1-4fb9-8263-b3a045928901"}}}}, {"uuid": "7b7eef78-375f-456d-852b-00b1d572d559", "name": "", "x": 38.70166339444126, "y": -122.38472871487578, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f55e4012-a11d-4883-baac-9c013aff6058", "name": "p1rdt33", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7b7eef78-375f-456d-852b-00b1d572d559"}}}}, {"uuid": "247189ff-cc8a-46c5-a8c4-302aa83aca0a", "name": "", "x": 38.7017418716262, "y": -122.38534278443267, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a01c83d1-4adb-4b2a-8de3-441d7c1dd054", "name": "p1rdt39", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "247189ff-cc8a-46c5-a8c4-302aa83aca0a"}}}}, {"uuid": "bd8ee146-d20a-4486-a4a6-8cc95bd84b7d", "name": "", "x": 38.701720915150304, "y": -122.38552827095313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dc531967-1a7b-4424-83ee-e1131c6fd94c", "name": "p1rdt73", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bd8ee146-d20a-4486-a4a6-8cc95bd84b7d"}}}}, {"uuid": "93962e5e-5dec-4444-8f0a-d3dcffea81d1", "name": "", "x": 38.70178214782518, "y": -122.38611126603591, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "510ea93c-7dd1-4fa3-ba3f-6c362856c7c1", "name": "p1rdt75", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "93962e5e-5dec-4444-8f0a-d3dcffea81d1"}}}}, {"uuid": "31ad3b66-1fa1-490b-bef3-43e3c128eca3", "name": "", "x": 38.70181286232661, "y": -122.3868125146921, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0aa0b7c2-9d55-4faf-8778-76a6f23bcf3e", "name": "p1rdt83", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "31ad3b66-1fa1-490b-bef3-43e3c128eca3"}}}}, {"uuid": "526cccc9-2c2a-4ed8-afcb-3a615e136d3a", "name": "", "x": 38.70215867171945, "y": -122.38789186166865, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b03f8e29-a5b2-4bed-b68c-219276674b6a", "name": "p1rdt80", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "526cccc9-2c2a-4ed8-afcb-3a615e136d3a"}}}}, {"uuid": "be8ad268-a3cf-443d-a0ec-9b264dda0a90", "name": "", "x": 38.697976462001364, "y": -122.39194580684853, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6e26e5dc-8c98-4fcd-b125-3265eb00f3f2", "name": "p1rdt263", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be8ad268-a3cf-443d-a0ec-9b264dda0a90"}}}}, {"uuid": "e49f82ab-a211-49e8-85c6-8633476c0695", "name": "", "x": 38.69710687368567, "y": -122.39904337583427, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "add5e39f-f02e-4a61-a156-d5721cec25d5", "name": "p1rdt277", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e49f82ab-a211-49e8-85c6-8633476c0695"}}}}, {"uuid": "78223a48-666e-4fcb-bebe-4311d1ecde6b", "name": "", "x": 38.69810207651738, "y": -122.40314189875019, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "186ffdfe-2346-4218-bd6b-b813ea6b3b62", "name": "p1rdt276", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "78223a48-666e-4fcb-bebe-4311d1ecde6b"}}}}, {"uuid": "01232a55-73d4-431f-b4e2-ab26730f7c11", "name": "", "x": 38.690000449751984, "y": -122.37232330919996, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9396562e-4f87-4e04-b248-502b851fe19e", "name": "p1rdt69", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "01232a55-73d4-431f-b4e2-ab26730f7c11"}}}}, {"uuid": "c3618ba1-cc9e-482c-b16e-58f3afed5c90", "name": "", "x": 38.689693582568, "y": -122.3712823494636, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b1bf1493-fb0d-40b4-8953-42e851a128d1", "name": "p1rdt44-p1rdt69x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c3618ba1-cc9e-482c-b16e-58f3afed5c90"}}}}, {"uuid": "abafd7f4-0cb8-4405-b252-6d3fa278f0eb", "name": "", "x": 38.68937758378194, "y": -122.37014905131693, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d9ee2ff-e2bc-4d76-b173-5ba5cc48c9b3", "name": "p1rdt44", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "abafd7f4-0cb8-4405-b252-6d3fa278f0eb"}}}}, {"uuid": "03aced16-e52e-475b-a740-04f3b1bf820b", "name": "", "x": 38.69011879726304, "y": -122.37274288833332, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f5b5b3ae-f657-4fd4-a311-ab1dbe9d749e", "name": "p1rdt41", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "03aced16-e52e-475b-a740-04f3b1bf820b"}}}}, {"uuid": "36d91d90-2790-49d6-b119-47c834f4234b", "name": "", "x": 38.690503780808164, "y": -122.3733294899771, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5a898f4c-f522-4e69-be4a-e935e339e011", "name": "p1rdt54", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "36d91d90-2790-49d6-b119-47c834f4234b"}}}}, {"uuid": "aaa1d980-d87f-4d7b-ac4e-4b123d9d1355", "name": "", "x": 38.690543520806486, "y": -122.37401904570497, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a778171c-22a1-4320-9e3c-43888d734e34", "name": "p1rdt42", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aaa1d980-d87f-4d7b-ac4e-4b123d9d1355"}}}}, {"uuid": "947f010e-99dd-41e2-96b2-bffab8e65938", "name": "", "x": 38.69014061173149, "y": -122.37513434619457, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "29a79372-9c75-4a9c-81df-a7491b87e58a", "name": "p1rdt45", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "947f010e-99dd-41e2-96b2-bffab8e65938"}}}}, {"uuid": "b407de02-85af-4ee9-8cd1-d1819848c2a8", "name": "", "x": 38.69057727021838, "y": -122.39183596993689, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "12451cbc-eb14-4814-b274-12eb2241c78a", "name": "p1rdt150", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b407de02-85af-4ee9-8cd1-d1819848c2a8"}}}}, {"uuid": "20710a8e-91b2-4c39-a742-bbc05da3aea2", "name": "", "x": 38.690031528872375, "y": -122.37717801542972, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "666bb367-692a-4127-8f77-d86d651768a1", "name": "p1rdt150-p1rdt45x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "20710a8e-91b2-4c39-a742-bbc05da3aea2"}}}}, {"uuid": "8ae76df5-4eda-4ab4-b4a6-5a6cc3bc0572", "name": "", "x": 38.694133300872906, "y": -122.39690517522077, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ba0ef4a3-43ba-469b-8ce8-ca7a5a984071", "name": "p1rdt260", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8ae76df5-4eda-4ab4-b4a6-5a6cc3bc0572"}}}}, {"uuid": "d3ad0f96-fc3e-4803-a9e7-5fb27f447339", "name": "", "x": 38.693518695228036, "y": -122.39600590196753, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e885b3e5-18fb-4454-b8e7-d82b4c72f6e8", "name": "p1rdt150-p1rdt260x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d3ad0f96-fc3e-4803-a9e7-5fb27f447339"}}}}, {"uuid": "3163f4ff-97fe-45fc-a29c-50928b93536f", "name": "", "x": 38.69620897416254, "y": -122.40296066033352, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "153bb615-5ee5-4eec-bcf7-94ea0098aeb6", "name": "p1rdt279", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3163f4ff-97fe-45fc-a29c-50928b93536f"}}}}, {"uuid": "a8a933b7-550e-458e-a813-a122f7e87ffb", "name": "", "x": 38.69807607310296, "y": -122.40309926707015, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7140d97e-416e-47ec-9f86-46ad6f9abece", "name": "p1rdt276-p1rdt279x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8a933b7-550e-458e-a813-a122f7e87ffb"}}}}, {"uuid": "aa93ecf8-6317-4e7e-8477-1c893b5d069b", "name": "", "x": 38.69819542243506, "y": -122.40314157925388, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c3ca9bee-26b0-4ef4-8555-6494ffdd6a17", "name": "p1rdt237-p1rdt276x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aa93ecf8-6317-4e7e-8477-1c893b5d069b"}}}}, {"uuid": "0ca3bc30-a32a-4240-89b1-4f3e26a789a5", "name": "", "x": 38.69933414700199, "y": -122.4089172598197, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "767b59ef-ecd9-4b17-8233-2033a02b2971", "name": "p1rdt237-p1rdt276xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0ca3bc30-a32a-4240-89b1-4f3e26a789a5"}}}}, {"uuid": "3781b958-1ce3-4d50-b11e-7a414f9249c8", "name": "", "x": 38.70123224209162, "y": -122.42082954062212, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "11571d26-573f-49f7-99fd-828dde97afd8", "name": "p1rdt445", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3781b958-1ce3-4d50-b11e-7a414f9249c8"}}}}, {"uuid": "597b89b3-1ee6-4948-af20-fb9177ddd8a9", "name": "", "x": 38.69940195487717, "y": -122.41580111174017, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b8c8b8f8-7a41-4d16-b509-2d7c7af9509d", "name": "p1rdt237", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "597b89b3-1ee6-4948-af20-fb9177ddd8a9"}}}}, {"uuid": "6c603289-21a7-43aa-9f84-f41ba7f6e016", "name": "", "x": 38.701258982520905, "y": -122.42203851637785, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "10620dcc-049c-4417-b4ac-922a56c0d4a2", "name": "p1rdt438", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c603289-21a7-43aa-9f84-f41ba7f6e016"}}}}, {"uuid": "cc52b747-000a-4eb9-8b06-9966684ef16d", "name": "", "x": 38.689358814642475, "y": -122.44266212701238, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e71eb2d5-cd10-498d-b9eb-ae337b2f8af6", "name": "p1rdt28", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc52b747-000a-4eb9-8b06-9966684ef16d"}}}}, {"uuid": "564731ca-f9e0-45c3-9794-cebe993202f6", "name": "", "x": 38.68721403983049, "y": -122.44207560107604, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b238dc5-7d8e-4b2d-8449-4dc212d7d227", "name": "p1rdt29", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "564731ca-f9e0-45c3-9794-cebe993202f6"}}}}, {"uuid": "9d4e97bd-a73c-4ed1-aad4-1c56fcfeb7f5", "name": "", "x": 38.68513046534505, "y": -122.45203222088253, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b07c4a6-39a7-4521-bce7-3f1ca0ff4a66", "name": "p1rdt335", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9d4e97bd-a73c-4ed1-aad4-1c56fcfeb7f5"}}}}, {"uuid": "74004cc2-1c07-40eb-b690-9af1a3df1329", "name": "", "x": 38.672940788437906, "y": -122.46748581101485, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d2efeaf5-2055-4718-a064-7c5e00b7d87d", "name": "p1rdt335-p1rdt419x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "74004cc2-1c07-40eb-b690-9af1a3df1329"}}}}, {"uuid": "bd6d72a5-0be7-43d2-8bdd-a587714676de", "name": "", "x": 38.670797093100916, "y": -122.46774549226095, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4cf05060-0a39-49a9-a761-79fb136e2965", "name": "p1rdt420", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bd6d72a5-0be7-43d2-8bdd-a587714676de"}}}}, {"uuid": "a7442dd9-11f1-4aa7-b011-7fe9acac7b86", "name": "", "x": 38.67291356677607, "y": -122.46744017800017, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "81cfd2a2-295c-4b73-abba-05ffee810523", "name": "p1rdt419", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a7442dd9-11f1-4aa7-b011-7fe9acac7b86"}}}}, {"uuid": "31607d9b-e1df-4994-b05a-19e19b826848", "name": "", "x": 38.66669420046755, "y": -122.46979269819516, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2eb3d4eb-71fc-46f3-b588-d223568c411c", "name": "p1rdt8167", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "31607d9b-e1df-4994-b05a-19e19b826848"}}}}, {"uuid": "755607de-9ddc-4da7-90ee-fa14c364aa50", "name": "", "x": 38.66526952797366, "y": -122.47022403577644, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3c93a476-4ad5-41cd-a07b-e2ccc9ef2c3b", "name": "p1rdt8180", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "755607de-9ddc-4da7-90ee-fa14c364aa50"}}}}, {"uuid": "ba2d9fb2-095f-4bb5-8b20-417d9d825944", "name": "", "x": 38.66479901416412, "y": -122.46771598894871, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f6bdb2cf-9373-4d56-a5f9-cb8fa9c67e55", "name": "p1rdt8169", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ba2d9fb2-095f-4bb5-8b20-417d9d825944"}}}}, {"uuid": "1859b7c8-60c3-43f1-b2f2-20c000be300e", "name": "", "x": 38.66152380322448, "y": -122.47383733708416, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "498a07ee-e12b-459a-a01f-f663a4a8428a", "name": "p1rdt8174-p1rdt8180x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1859b7c8-60c3-43f1-b2f2-20c000be300e"}}}}, {"uuid": "91f2ce3d-3736-4c91-8287-a517bda95203", "name": "", "x": 38.6604983255136, "y": -122.47346682060977, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8997dae6-8970-4762-98e9-0617375633d6", "name": "p1rdt8195", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "91f2ce3d-3736-4c91-8287-a517bda95203"}}}}, {"uuid": "d9edddcb-9fa1-475f-9bf6-503a8412b109", "name": "", "x": 38.66147939586647, "y": -122.47384646091422, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6b0f9433-e0a3-458a-8687-c9cf38d0bbb3", "name": "p1rdt8174", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d9edddcb-9fa1-475f-9bf6-503a8412b109"}}}}, {"uuid": "cb97c63c-d7ff-485c-9dfe-4e26ebff9985", "name": "", "x": 38.658272650826795, "y": -122.47501655241358, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "081feb5c-d5d5-405e-85d4-f1dd0916fc3d", "name": "p1rdt7757", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb97c63c-d7ff-485c-9dfe-4e26ebff9985"}}}}, {"uuid": "14c338c8-ab4b-486b-a84b-27dda3b552bc", "name": "", "x": 38.655197924044465, "y": -122.48096925268166, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "68117bef-16c5-40c9-9356-76ef5c056650", "name": "p1rdt5560", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "14c338c8-ab4b-486b-a84b-27dda3b552bc"}}}}, {"uuid": "cd9b5143-5e3c-47a8-8356-96be17119efb", "name": "", "x": 38.6571578603823, "y": -122.47877412021943, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b64b7bd6-06e4-45f7-b987-efc7d09b91f8", "name": "p1rdt5560-p1rdt7757x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cd9b5143-5e3c-47a8-8356-96be17119efb"}}}}, {"uuid": "7a8878fb-4cdc-4fa9-b40d-55bc8657a357", "name": "", "x": 38.6544084693578, "y": -122.48126098888899, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8444c9ea-ff7a-4b0a-9ea6-9c18770565cb", "name": "p1rdt5564", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7a8878fb-4cdc-4fa9-b40d-55bc8657a357"}}}}, {"uuid": "c1427e78-5470-44e6-90f6-405b0dcda489", "name": "", "x": 38.65411176650942, "y": -122.48165516473325, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ad24f98d-f022-4e62-b80b-426052810759", "name": "p1rdt5563", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c1427e78-5470-44e6-90f6-405b0dcda489"}}}}, {"uuid": "ad5db67d-1964-4568-ad89-8f27ba79aa8d", "name": "", "x": 38.65399305368811, "y": -122.48234388532953, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c94489ed-4399-4dab-bab6-02b79f240f63", "name": "p1rdt5557-p1rdt5563x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ad5db67d-1964-4568-ad89-8f27ba79aa8d"}}}}, {"uuid": "b159b55d-cc9f-46ad-bf19-5d08b45496f4", "name": "", "x": 38.65409795953588, "y": -122.48170621590174, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fbc31b75-f942-4bae-8712-f1666d8b7f26", "name": "p1rdt5557-p1rdt5563xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b159b55d-cc9f-46ad-bf19-5d08b45496f4"}}}}, {"uuid": "cbcd009a-0c20-4d15-a018-6b45b447e5a2", "name": "", "x": 38.65386072697981, "y": -122.48298842075683, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "efe7243f-340b-4114-be7c-f7494e78384f", "name": "p1rdt5557-p1rdt5565xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cbcd009a-0c20-4d15-a018-6b45b447e5a2"}}}}, {"uuid": "0a21d5f6-b987-4af0-8cad-052a586d9aaf", "name": "", "x": 38.6540547104338, "y": -122.48228339829146, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bfe92e2e-285d-4c58-8e0b-a462dd73fa41", "name": "p1rdt5557-p1rdt5565x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a21d5f6-b987-4af0-8cad-052a586d9aaf"}}}}, {"uuid": "53b7a282-efd7-49b9-8b4c-e3660d062d2f", "name": "", "x": 38.653744336845875, "y": -122.48342339339821, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8bd0860f-2b3e-4c90-a571-cfc6aa649e5b", "name": "p1rdt5561-p1rdt5565x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "53b7a282-efd7-49b9-8b4c-e3660d062d2f"}}}}, {"uuid": "83fe7a48-cf07-4fea-aee2-6f82ef002e17", "name": "", "x": 38.653922384064785, "y": -122.48292793438009, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bebca5d7-2d4f-4655-a965-9faafd7a8125", "name": "p1rdt5561-p1rdt5565xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "83fe7a48-cf07-4fea-aee2-6f82ef002e17"}}}}, {"uuid": "e16a0510-15af-4338-ad06-536625606dae", "name": "", "x": 38.653656874338274, "y": -122.48382172207613, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "27ab530f-a58e-4113-80f6-63f768910204", "name": "p1rdt5551-p1rdt5561x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e16a0510-15af-4338-ad06-536625606dae"}}}}, {"uuid": "4d8bd976-82f1-4fab-984f-87546cf80006", "name": "", "x": 38.65368267949884, "y": -122.4834838792017, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bf97a458-469e-4609-bb33-97454e7c2b68", "name": "p1rdt5551-p1rdt5561xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d8bd976-82f1-4fab-984f-87546cf80006"}}}}, {"uuid": "0d7f3c2b-6d04-41bd-b92d-4a2665f338a3", "name": "", "x": 38.65357363505309, "y": -122.48418848997771, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d447cf8-7b2b-45f1-8084-6fe4897e1853", "name": "p1rdt5548-p1rdt5551x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0d7f3c2b-6d04-41bd-b92d-4a2665f338a3"}}}}, {"uuid": "bf13386c-86ca-40dc-8ce9-f0367315b4ae", "name": "", "x": 38.65359832142837, "y": -122.48384598170813, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5ec70f12-a676-48cd-b626-34f8d7f6a5bf", "name": "p1rdt5548-p1rdt5551xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bf13386c-86ca-40dc-8ce9-f0367315b4ae"}}}}, {"uuid": "58902d6a-effa-4407-ade5-fc151647b853", "name": "", "x": 38.65344193779202, "y": -122.48465054385285, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "10f43169-4b4b-4dbe-8f09-af72d427d6c7", "name": "p1rdt5548-p1rdt5566xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "58902d6a-effa-4407-ade5-fc151647b853"}}}}, {"uuid": "fa35428d-ad2e-4833-92af-155777d08869", "name": "", "x": 38.65355345327659, "y": -122.48411429646117, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "23163dba-070c-435c-bb90-77be7ded002a", "name": "p1rdt5548-p1rdt5566x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa35428d-ad2e-4833-92af-155777d08869"}}}}, {"uuid": "62505c49-18d7-4dc7-88a2-27afcb42e823", "name": "", "x": 38.65349305461597, "y": -122.48469671958328, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bf619f04-1fa5-4be7-8a76-669b79436d3e", "name": "p1rdt5566-p1rdt5574xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "62505c49-18d7-4dc7-88a2-27afcb42e823"}}}}, {"uuid": "d3ac96ef-09fb-4bae-b143-3a065d9d9ad1", "name": "", "x": 38.65351374951022, "y": -122.48468872832316, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c264e6de-a898-421d-a2fe-ce6548aa477e", "name": "p1rdt5566-p1rdt5574x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d3ac96ef-09fb-4bae-b143-3a065d9d9ad1"}}}}, {"uuid": "06702de2-f8c8-4589-8236-bca704fa692d", "name": "", "x": 38.6521229408726, "y": -122.4867812786121, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "17b633c6-214d-4428-bded-df737f50ffb6", "name": "p1rdt8138", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "06702de2-f8c8-4589-8236-bca704fa692d"}}}}, {"uuid": "0173173b-eac5-4e26-8f41-c21afd87760e", "name": "", "x": 38.65212339039547, "y": -122.48678923108443, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2c8fd701-7842-49c1-b630-7ae1ad49739f", "name": "p1rdt5574-p1rdt8138x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0173173b-eac5-4e26-8f41-c21afd87760e"}}}}, {"uuid": "7596258b-68d1-4f85-b881-4661a9159a6c", "name": "", "x": 38.6534675320259, "y": -122.48473979533868, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e9906676-e9b9-4d51-b1c2-a6b6fe187faa", "name": "p1rdt5574", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7596258b-68d1-4f85-b881-4661a9159a6c"}}}}, {"uuid": "2f74bd6e-72a9-42da-a509-e0390ecfbf81", "name": "", "x": 38.64755444307129, "y": -122.50915596024865, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "63b2f1e6-5e15-4433-85ee-ff7bb7218b96", "name": "p1rdt6488", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2f74bd6e-72a9-42da-a509-e0390ecfbf81"}}}}, {"uuid": "0bbf498a-e4cc-40d6-a250-682263afe9bd", "name": "", "x": 38.647519963483695, "y": -122.50475738860712, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "548ba541-a511-486c-876c-c841a6e482af", "name": "p1rdt6488-p1rdt8138x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0bbf498a-e4cc-40d6-a250-682263afe9bd"}}}}, {"uuid": "e0bc28a4-d366-4769-b729-d481f566e45b", "name": "", "x": 38.653569957917405, "y": -122.48377667700575, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a9dec144-ef2e-44fe-990a-c9d70b740410", "name": "p1rdt5551lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e0bc28a4-d366-4769-b729-d481f566e45b"}}}}, {"uuid": "0edb9ce5-61b9-441c-8a5a-d23c20926863", "name": "", "x": 38.653349320804885, "y": -122.48361706572747, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "82988650-787d-41de-bca7-4f3c08ccad15", "name": "p1rlv11506", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0edb9ce5-61b9-441c-8a5a-d23c20926863"}}}}, {"uuid": "a749a880-49d7-464e-abad-60ef90fb20cf", "name": "", "x": 38.65393253922449, "y": -122.48302660355507, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60dc1291-a843-4abf-bfc6-ff8afc8c0b98", "name": "p1rdt5565lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a749a880-49d7-464e-abad-60ef90fb20cf"}}}}, {"uuid": "edd8090c-62f3-41ba-b6c3-d35d218dc4e9", "name": "", "x": 38.65344458882935, "y": -122.48274295264503, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "176b348f-9ecf-4a82-bdf9-f2e5d5a07af7", "name": "p1rlv11522", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "edd8090c-62f3-41ba-b6c3-d35d218dc4e9"}}}}, {"uuid": "f15e74bc-cd3f-4502-bdbc-ac249f73eea8", "name": "", "x": 38.65413728795049, "y": -122.4816120875077, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0a150dd3-61a4-4df9-90e2-6c72f80af819", "name": "p1rdt5563lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f15e74bc-cd3f-4502-bdbc-ac249f73eea8"}}}}, {"uuid": "4ba1e7ab-c731-42a2-b1cf-1a4a3eee3337", "name": "", "x": 38.65368296548394, "y": -122.48162646334242, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "22054033-4e69-41b0-b321-a4d086d20574", "name": "p1rlv11520", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ba1e7ab-c731-42a2-b1cf-1a4a3eee3337"}}}}, {"uuid": "2721271a-309e-4478-a9f3-411791dd008f", "name": "", "x": 38.707239856986014, "y": -122.42485436421835, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c5fd6466-e740-4f06-a842-798195d62154", "name": "p1rdt252lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2721271a-309e-4478-a9f3-411791dd008f"}}}}, {"uuid": "8c301039-3b06-4026-9cfd-61173d74a637", "name": "", "x": 38.70723070261674, "y": -122.4249071150479, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a23f97bc-e7ef-4f64-9e64-314f4a4e17d8", "name": "p1rlv440", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8c301039-3b06-4026-9cfd-61173d74a637"}}}}, {"uuid": "beb8a8dd-d1ae-4c46-a0b8-9164b1204cd1", "name": "", "x": 38.65363370971865, "y": -122.48373653900416, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "514ad102-b590-4ad8-a258-2b6fa8dcbeb1", "name": "p1rdt5551-p1rdt5568x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "beb8a8dd-d1ae-4c46-a0b8-9164b1204cd1"}}}}, {"uuid": "5fd03be4-748d-4158-a92d-24b0cc0a9305", "name": "", "x": 38.65350635684874, "y": -122.48421628994025, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25ee6008-ddbc-4e7b-8a57-ff38c16368a2", "name": "p1rdt5548-p1rdt5577x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5fd03be4-748d-4158-a92d-24b0cc0a9305"}}}}, {"uuid": "bf563631-9bac-4a2c-9536-752dae925812", "name": "", "x": 38.65213674275478, "y": -122.48364605819339, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1c8b424-4509-4fd2-93e2-4fd54f6cf49a", "name": "p1rdt5577", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bf563631-9bac-4a2c-9536-752dae925812"}}}}, {"uuid": "406f41ee-91ce-4a71-849a-80eed4ccd2c4", "name": "", "x": 38.65403765024386, "y": -122.48233644072755, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cca8918c-30e6-4619-a5e0-8c0d3451f9c4", "name": "p1rdt5557", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "406f41ee-91ce-4a71-849a-80eed4ccd2c4"}}}}, {"uuid": "bbda2575-698a-42f3-b5bf-3a83b99b842a", "name": "", "x": 38.65390532358046, "y": -122.48298097656864, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b5e479d3-aae0-47b8-b707-bad1191df1e7", "name": "p1rdt5565", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bbda2575-698a-42f3-b5bf-3a83b99b842a"}}}}, {"uuid": "c0e900d1-a01a-4a5a-9d85-1a6d12778a63", "name": "", "x": 38.65372727613462, "y": -122.48347643534002, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "756f6cd8-301b-4fac-b414-d72853616c6e", "name": "p1rdt5561", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c0e900d1-a01a-4a5a-9d85-1a6d12778a63"}}}}, {"uuid": "ddd5810d-928e-4fa9-96db-426ae8d4092e", "name": "", "x": 38.653615927095316, "y": -122.48379127781236, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5f7fed4f-197e-4a79-97e5-df595377736b", "name": "p1rdt5551", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ddd5810d-928e-4fa9-96db-426ae8d4092e"}}}}, {"uuid": "99b54ad7-1ddb-4d8c-8305-c45ad70177b3", "name": "", "x": 38.653529895117565, "y": -122.48416522717811, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6bf1b63d-fbce-42f8-9948-2e09bfa67409", "name": "p1rdt5548", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "99b54ad7-1ddb-4d8c-8305-c45ad70177b3"}}}}, {"uuid": "25286f23-9994-4df7-a510-04d00e26e939", "name": "", "x": 38.65348653464999, "y": -122.48464310081867, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9fed9557-b170-4817-8bd8-efc3b9f7c982", "name": "p1rdt5566", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "25286f23-9994-4df7-a510-04d00e26e939"}}}}, {"uuid": "1f82ec4b-389f-44b2-8e92-0331097de9d4", "name": "", "x": 38.65857449295584, "y": -122.51047390361627, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16ace27f-f5fa-4fd1-840e-8cae55dbe1b2", "name": "p1rdt383-p1rdt7300x_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1f82ec4b-389f-44b2-8e92-0331097de9d4"}}}}, {"uuid": "11d5fb2d-a11f-4cca-a32d-a54a006ec224", "name": "", "x": 38.755774152251824, "y": -122.36924141377668, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e6b5c947-b0c5-4e20-bd74-bf847bdacd30", "name": "p1rdt181_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "11d5fb2d-a11f-4cca-a32d-a54a006ec224"}}}}, {"uuid": "a94365ec-ba7e-41ad-9b88-27ea9076b835", "name": "", "x": 38.76763103931847, "y": -122.38059245720176, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "99615f32-0614-4c23-a1e1-b3e8e5688cce", "name": "p1rdt66", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a94365ec-ba7e-41ad-9b88-27ea9076b835"}}}}, {"uuid": "8e2b886e-e1fc-41ea-a1e8-76febb13f1e2", "name": "", "x": 38.73066670610679, "y": -122.39985796643494, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "71abd5f1-ca61-4754-a2ef-7b5d4e635f99", "name": "p1rdt181-p1rdt297x_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8e2b886e-e1fc-41ea-a1e8-76febb13f1e2"}}}}, {"uuid": "4d02be35-fcba-456e-b90e-38db765a0ac1", "name": "", "x": 38.73098682493839, "y": -122.41321244241928, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b0fad7ee-b65c-460c-94ca-fe9546a5b140", "name": "p1rdt270-p1rdt298x_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d02be35-fcba-456e-b90e-38db765a0ac1"}}}}, {"uuid": "639ab63c-d85d-49e0-bfb2-74b043b6dcba", "name": "", "x": 38.68766311446792, "y": -122.34290029588801, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b8064f1d-11b7-4913-8344-175c1388be3e", "name": "p1rdt16604-p1rdt257x_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "639ab63c-d85d-49e0-bfb2-74b043b6dcba"}}}}, {"uuid": "d63106f2-69d0-425e-9c68-7a00109bd753", "name": "", "x": 38.6006266312945, "y": -122.52427556411426, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e2131350-dc34-4d8d-8c9f-c29e25bc654c", "name": "p1rdt7711", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d63106f2-69d0-425e-9c68-7a00109bd753"}}}}, {"uuid": "15ce6336-bc93-4d4a-8034-cf23d75b7464", "name": "", "x": 38.60058489010104, "y": -122.52426789727744, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "64b60527-0853-4973-8d7a-78ba5e377799", "name": "p1rdt7711lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "15ce6336-bc93-4d4a-8034-cf23d75b7464"}}}}, {"uuid": "b247caad-f974-4017-a99d-5bfa5bf2b928", "name": "", "x": 38.600468680548644, "y": -122.5242248045325, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3ed6276c-a57b-40be-a1f1-34aaaba0ac28", "name": "p1rlv16411", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b247caad-f974-4017-a99d-5bfa5bf2b928"}}}}, {"uuid": "a07a22f5-d840-47dd-9319-457197a96756", "name": "", "x": 38.60059554402563, "y": -122.52439622804972, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e0a92e79-0ca2-4a10-9050-9e8d7442b019", "name": "p1rlv20414", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a07a22f5-d840-47dd-9319-457197a96756"}}}}, {"uuid": "6eedbed5-071e-429f-9cb3-c1cf4e13a452", "name": "", "x": 38.59743372341483, "y": -122.52848624702995, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "439728c5-fee5-4dfa-9894-261ba6c40e95", "name": "p1rdt8473lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6eedbed5-071e-429f-9cb3-c1cf4e13a452"}}}}, {"uuid": "8f49bd92-9100-4688-a6c3-8c7dab784aa0", "name": "", "x": 38.59755648297391, "y": -122.52834367013348, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3c1eac45-623a-4f0a-874d-a4b56a8e2ea7", "name": "p1rlv18169", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8f49bd92-9100-4688-a6c3-8c7dab784aa0"}}}}, {"uuid": "c750bbe3-7c46-4b17-8dda-052506550e67", "name": "", "x": 38.59726926605651, "y": -122.52863263826859, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "949f4cce-f321-4bf0-830b-489edc9964c7", "name": "p1rlv18194", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c750bbe3-7c46-4b17-8dda-052506550e67"}}}}, {"uuid": "c7fc9e30-46b9-4818-b666-3885d4c69c23", "name": "", "x": 38.5973486590682, "y": -122.53115453060339, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35f6f747-811d-4fe2-a9c7-991248572c74", "name": "p1rdt6028lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c7fc9e30-46b9-4818-b666-3885d4c69c23"}}}}, {"uuid": "d612deb0-ae01-4e0e-8f3c-4dc7320ec9aa", "name": "", "x": 38.597359644970844, "y": -122.53094024225281, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "72f659b6-d302-4887-a2f6-1a477ad3324c", "name": "p1rlv12518", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d612deb0-ae01-4e0e-8f3c-4dc7320ec9aa"}}}}, {"uuid": "f82d5b04-ca0c-4334-a89a-1e8dcc3def3c", "name": "", "x": 38.597740803009394, "y": -122.53160381152783, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f9660b80-0fce-4be4-b541-743d5811133c", "name": "p1rlv12528", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f82d5b04-ca0c-4334-a89a-1e8dcc3def3c"}}}}, {"uuid": "0d020d98-a846-403c-9afb-ee0db1c7029d", "name": "", "x": 38.59730635717321, "y": -122.53113580939358, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8796d817-aad6-4d22-b3d4-baf8a686c9df", "name": "p1rlv12534", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0d020d98-a846-403c-9afb-ee0db1c7029d"}}}}, {"uuid": "7e1a9607-6da1-4730-9899-d1a9821d629a", "name": "", "x": 38.597059503153865, "y": -122.53096119189571, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e89452f3-ce44-46d3-a259-f66044e01c2c", "name": "p1rlv12536", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7e1a9607-6da1-4730-9899-d1a9821d629a"}}}}, {"uuid": "64714c99-eb77-45de-8558-c4ccb0182909", "name": "", "x": 38.598068610661386, "y": -122.54952501293569, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ddf38626-1223-429f-a903-98f1c975020b", "name": "p1rdt9478lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "64714c99-eb77-45de-8558-c4ccb0182909"}}}}, {"uuid": "f8becd39-60a8-4e1e-9c22-bb224d6ad808", "name": "", "x": 38.59809415769325, "y": -122.54948199323535, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cebe1b53-cca6-4bd4-a9f0-616ffb9750b3", "name": "p1rlv20501", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f8becd39-60a8-4e1e-9c22-bb224d6ad808"}}}}, {"uuid": "eba7b3a6-8113-470f-a84e-d5f0ed18ecb5", "name": "", "x": 38.59772028985937, "y": -122.55034252722092, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3e2630e1-a215-4740-9327-fa004e89863d", "name": "p1rdt6232lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eba7b3a6-8113-470f-a84e-d5f0ed18ecb5"}}}}, {"uuid": "6d3aa3aa-641b-4303-8721-8f50561f013f", "name": "", "x": 38.59770645245217, "y": -122.5503935254409, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "df3aae83-f4b0-4db2-9301-dff1664ac23e", "name": "p1rlv12985", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6d3aa3aa-641b-4303-8721-8f50561f013f"}}}}, {"uuid": "abda40da-fda1-41de-a3fa-a0c7ca091e4f", "name": "", "x": 38.59805477361372, "y": -122.54957601155624, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c49b6e87-5834-4e7e-a64c-b4ec0f7d4995", "name": "p1rdt9478", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "abda40da-fda1-41de-a3fa-a0c7ca091e4f"}}}}, {"uuid": "7465d552-f9fd-4c18-bbcb-046e2214089f", "name": "", "x": 38.59774583719626, "y": -122.55029950801654, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b59ad93a-cca2-4a77-8515-a645ddd2a320", "name": "p1rdt6232", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7465d552-f9fd-4c18-bbcb-046e2214089f"}}}}, {"uuid": "a45aed2c-9785-4267-b6c9-93de8a2eb205", "name": "", "x": 38.59739040278303, "y": -122.53116220049235, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e39cb1db-d6a6-4b6c-bc73-920e0c34c292", "name": "p1rdt6028", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a45aed2c-9785-4267-b6c9-93de8a2eb205"}}}}, {"uuid": "47744c39-d0fa-4c6b-8dd3-2d10ae71edc2", "name": "", "x": 38.602431647117115, "y": -122.53503011701754, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f77960bf-f017-400c-b505-16e7c2e90fe7", "name": "p1rdt6028_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "47744c39-d0fa-4c6b-8dd3-2d10ae71edc2"}}}}, {"uuid": "73fddd2a-9c61-4c25-bfc8-9b3588a86e04", "name": "", "x": 38.597391979534734, "y": -122.52847857868831, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b3a83211-0829-4e2c-b618-3f1fcaba3e87", "name": "p1rdt8473", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "73fddd2a-9c61-4c25-bfc8-9b3588a86e04"}}}}, {"uuid": "d47488e2-6469-4439-a236-085f77265a79", "name": "", "x": 38.59407749157057, "y": -122.52505662658886, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c330731a-fd2c-40c7-8fce-94f7e17cf6d9", "name": "p1rdt8493lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d47488e2-6469-4439-a236-085f77265a79"}}}}, {"uuid": "c5d6d872-0cb7-44a4-8b2a-1680dd82e11e", "name": "", "x": 38.594091817303486, "y": -122.52510740253169, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ead37cb8-af1e-4a46-9466-6ff298b7f8b7", "name": "p1rlv18201", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c5d6d872-0cb7-44a4-8b2a-1680dd82e11e"}}}}, {"uuid": "d543b5e5-21eb-4d18-83f8-f17b77f46c83", "name": "", "x": 38.59405153241799, "y": -122.52501401155037, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cfb41891-7063-44b8-9286-1fe763e49924", "name": "p1rdt8493", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d543b5e5-21eb-4d18-83f8-f17b77f46c83"}}}}, {"uuid": "e2336c83-39fe-4b64-9b84-2eb2f4408be8", "name": "", "x": 38.6026030514407, "y": -122.53507494861152, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "409a29cf-ddd5-4031-92ca-db6cd2410704", "name": "p1rdt6028_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e2336c83-39fe-4b64-9b84-2eb2f4408be8"}}}}, {"uuid": "84a1a7b9-2f6d-432e-8a26-762b186fd77d", "name": "", "x": 38.67296456591668, "y": -122.57311952323086, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0921e58d-1ada-4556-8b01-8f22d3bf4ee2", "name": "p1rdt93lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "84a1a7b9-2f6d-432e-8a26-762b186fd77d"}}}}, {"uuid": "19391878-f7ac-418c-985a-d1d03bec6f38", "name": "", "x": 38.67288108818913, "y": -122.57387827884625, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3df778b4-e60b-4e17-b24b-67742d090f42", "name": "p1rlv183", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "19391878-f7ac-418c-985a-d1d03bec6f38"}}}}, {"uuid": "08de448b-f269-408e-8555-53810fe0aea3", "name": "", "x": 38.67284336560701, "y": -122.57341867755696, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d663fcdc-6c67-4bc9-99ed-12439f75804f", "name": "p1rlv204", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "08de448b-f269-408e-8555-53810fe0aea3"}}}}, {"uuid": "afc1a4c5-298c-454e-94d8-c72167c86521", "name": "", "x": 38.672896260917035, "y": -122.57309648596055, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2be21180-bfa8-4cd1-a3c5-68602896d657", "name": "p1rdm198", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "afc1a4c5-298c-454e-94d8-c72167c86521"}}}}, {"uuid": "f2445300-d709-40be-9352-addfc8d3546e", "name": "", "x": 38.67255503590974, "y": -122.57343188427429, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "90aa0d14-285a-4468-bbde-8d76f65b1780", "name": "p1rlv206", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f2445300-d709-40be-9352-addfc8d3546e"}}}}, {"uuid": "38a53f09-a685-40f7-b20c-a7170caea4fb", "name": "", "x": 38.67306781717814, "y": -122.57318743231879, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6a70fd02-3816-451f-a509-2ad767068eb4", "name": "p1rdm199", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "38a53f09-a685-40f7-b20c-a7170caea4fb"}}}}, {"uuid": "0c9426a0-9096-48e9-90ab-ad9746ad6f6f", "name": "", "x": 38.67309761817342, "y": -122.5739459691624, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6627102c-4524-4e69-bb4d-5b93226df412", "name": "p1rlv207", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0c9426a0-9096-48e9-90ab-ad9746ad6f6f"}}}}, {"uuid": "6210c740-6072-4fd5-8cb2-494c338084d5", "name": "", "x": 38.673202949412286, "y": -122.57317513422406, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6065e92f-dd89-4aeb-94af-173d81a49df1", "name": "p1rdm196", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6210c740-6072-4fd5-8cb2-494c338084d5"}}}}, {"uuid": "383df165-d455-44d1-aaa7-d9d026fa4bf3", "name": "", "x": 38.67319695527533, "y": -122.57400285874593, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "42ca8327-5dcc-415a-820c-ef6ec038b3d8", "name": "p1rlv184", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "383df165-d455-44d1-aaa7-d9d026fa4bf3"}}}}, {"uuid": "0fb5e2e8-91ff-4337-ae5c-5874c4a5a5b4", "name": "", "x": 38.6716242440999, "y": -122.57350240564409, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ef6be92d-5d1b-40e2-a2c2-9d0c1f0bf596", "name": "p1rdt99lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0fb5e2e8-91ff-4337-ae5c-5874c4a5a5b4"}}}}, {"uuid": "121accee-3c5d-4d8e-afbd-aa488401ee1b", "name": "", "x": 38.67172785280663, "y": -122.57395408806927, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33b6400e-c84e-43cf-b254-99f946e5a308", "name": "p1rlv190", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "121accee-3c5d-4d8e-afbd-aa488401ee1b"}}}}, {"uuid": "9ab562c3-fcf0-48cb-91a8-6a775a66e30e", "name": "", "x": 38.671562374281784, "y": -122.57305842624851, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "de2366e4-30da-429a-82b9-c0ef27eeab47", "name": "p1rlv202", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9ab562c3-fcf0-48cb-91a8-6a775a66e30e"}}}}, {"uuid": "371eadd3-a103-436e-b114-f0c24aaa1d57", "name": "", "x": 38.674085731551074, "y": -122.57304573384614, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1277a701-9fbd-4853-a809-962475e016c4", "name": "p1rdt101lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "371eadd3-a103-436e-b114-f0c24aaa1d57"}}}}, {"uuid": "11a58949-2b98-49be-b558-d21e2a7bea41", "name": "", "x": 38.674164000252716, "y": -122.57229574382116, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "84223c1b-69e4-4ebc-8274-8706bb412780", "name": "p1rlv193", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "11a58949-2b98-49be-b558-d21e2a7bea41"}}}}, {"uuid": "3042c514-d9a7-4cbf-b292-08e4f7e3bf5f", "name": "", "x": 38.673326264900375, "y": -122.57317042703883, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3aa8d6f2-8d84-42d6-8e7b-89e3b1efa03c", "name": "p1rdt108lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3042c514-d9a7-4cbf-b292-08e4f7e3bf5f"}}}}, {"uuid": "fba9d52a-56da-4743-9f43-d8e41e614e35", "name": "", "x": 38.673338794652196, "y": -122.57335825878279, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a982feac-5730-4fe0-a1b8-25c06b36e3b0", "name": "p1rlv212", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fba9d52a-56da-4743-9f43-d8e41e614e35"}}}}, {"uuid": "6f53652c-c937-430f-839f-ab69e81b2b63", "name": "", "x": 38.661367233687706, "y": -122.56984548041399, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "448cc5e0-391f-4a6b-8199-25cef4593edf", "name": "p1rdt6121lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6f53652c-c937-430f-839f-ab69e81b2b63"}}}}, {"uuid": "489d0901-4beb-4fa1-98a8-56a8df5765df", "name": "", "x": 38.66161605427373, "y": -122.56888775894382, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "163c3824-6847-4b94-9e81-08f15f4667a1", "name": "p1rlv12687", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "489d0901-4beb-4fa1-98a8-56a8df5765df"}}}}, {"uuid": "18b06d68-ca94-4d75-b53f-e26986e76248", "name": "", "x": 38.66221308963423, "y": -122.56844471302269, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e81ba94-5857-42e4-aeee-58542cef0fb6", "name": "p1rdt6123lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "18b06d68-ca94-4d75-b53f-e26986e76248"}}}}, {"uuid": "5ab40600-e462-49b4-a6e1-97fcebd2e9c8", "name": "", "x": 38.662187146256294, "y": -122.5684020420726, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ff16aad0-98c1-4563-a844-e0ce909c1a79", "name": "p1rlv12713", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ab40600-e462-49b4-a6e1-97fcebd2e9c8"}}}}, {"uuid": "48892e13-368b-44ee-824c-fa7c114949e5", "name": "", "x": 38.666474403379304, "y": -122.59876007752939, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8428de0e-4b06-4f19-bffb-5fed32f96f67", "name": "p1rdt8017lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "48892e13-368b-44ee-824c-fa7c114949e5"}}}}, {"uuid": "4417ff6d-d2ea-4fe9-88cb-de12f1a6ab25", "name": "", "x": 38.666431086206416, "y": -122.59829258598047, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b53edd15-5a3e-4b7a-97c4-046582bb4801", "name": "p1rlv17006", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4417ff6d-d2ea-4fe9-88cb-de12f1a6ab25"}}}}, {"uuid": "308b380d-d41b-45f3-96de-9e617604886e", "name": "", "x": 38.66353413238862, "y": -122.60568928818653, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a367e687-b29a-44b4-a943-7b94762e549e", "name": "p1rdt8043lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "308b380d-d41b-45f3-96de-9e617604886e"}}}}, {"uuid": "08f15de6-260e-419d-911e-b628e755ff37", "name": "", "x": 38.6635082025271, "y": -122.60564660289965, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8ff9eb4c-2523-48e0-8490-619d26b9cca4", "name": "p1rlv17103", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "08f15de6-260e-419d-911e-b628e755ff37"}}}}, {"uuid": "3f5eea31-80ca-4830-9a4c-66869b9db1a5", "name": "", "x": 38.656285239065134, "y": -122.61480721656375, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8bb025c5-31eb-4771-b433-e1dcad03b3ed", "name": "p1rdt8065lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3f5eea31-80ca-4830-9a4c-66869b9db1a5"}}}}, {"uuid": "c7d84cbf-8e4a-40fa-948c-a37206aa3f12", "name": "", "x": 38.65636014038154, "y": -122.61479929639421, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3c6c52e-cf93-467a-a303-94b96b33a3da", "name": "p1rlv17155", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c7d84cbf-8e4a-40fa-948c-a37206aa3f12"}}}}, {"uuid": "57105b01-9e4d-457c-a82e-90b19eb89a1a", "name": "", "x": 38.65653706419615, "y": -122.61653379624518, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "62e77e46-bf33-474f-907b-81d36aae8975", "name": "p1rdm17752", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "57105b01-9e4d-457c-a82e-90b19eb89a1a"}}}}, {"uuid": "59295e4b-87ad-415c-8961-0244dffcbade", "name": "", "x": 38.656142018437656, "y": -122.61698412819987, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "041caa30-2985-44ca-8013-e11a9bda7dff", "name": "p1rlv17164", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59295e4b-87ad-415c-8961-0244dffcbade"}}}}, {"uuid": "73d19644-a33b-400d-bc6c-0b09086220d9", "name": "", "x": 38.65646182364152, "y": -122.61643827928047, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dd01eed6-0e70-42e7-ac29-4bfd2f70366a", "name": "p1rdt8068lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "73d19644-a33b-400d-bc6c-0b09086220d9"}}}}, {"uuid": "e8387e72-4704-4ccd-ba30-31f1bae60656", "name": "", "x": 38.6564643300682, "y": -122.61633880273914, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "46b5c5bc-6738-4520-b98c-32bd43f4c91c", "name": "p1rdm17753", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e8387e72-4704-4ccd-ba30-31f1bae60656"}}}}, {"uuid": "04a61433-ab27-4c19-8d09-b9a8f24e0620", "name": "", "x": 38.65583419030237, "y": -122.6165490366375, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5768eaca-abe3-4347-af78-02b50ec6f2a9", "name": "p1rlv17199", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "04a61433-ab27-4c19-8d09-b9a8f24e0620"}}}}, {"uuid": "e26f0031-1622-4dc5-844f-d31e2652eff3", "name": "", "x": 38.656487161757404, "y": -122.6159209581833, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d0bcd460-ccf2-42ee-83c6-bada397ab4d6", "name": "p1rdt8070lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e26f0031-1622-4dc5-844f-d31e2652eff3"}}}}, {"uuid": "ddb8eca2-3f6e-48b5-9bd6-8b8c916885cf", "name": "", "x": 38.65609360641926, "y": -122.61596151268897, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2b4e44ab-e644-4e48-b1b2-82dc15d38d17", "name": "p1rlv17167", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ddb8eca2-3f6e-48b5-9bd6-8b8c916885cf"}}}}, {"uuid": "5d80fb83-4c57-405b-be79-fefbfe9f0f29", "name": "", "x": 38.66692113690325, "y": -122.58783715855819, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f21f4e99-8877-4bb0-9956-9240bc6db3d1", "name": "p1rdt8190lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5d80fb83-4c57-405b-be79-fefbfe9f0f29"}}}}, {"uuid": "0ec4963f-c030-40aa-8f4c-bf6e68b00d71", "name": "", "x": 38.66724289358908, "y": -122.58733754347764, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8c9970ae-e914-407d-8222-12c08638a854", "name": "p1rlv17376", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0ec4963f-c030-40aa-8f4c-bf6e68b00d71"}}}}, {"uuid": "d61466da-7b42-4518-90f7-f4815488ce05", "name": "", "x": 38.664369444812806, "y": -122.58690973341812, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d12bf6fb-8dac-4729-bcda-1ee61c63f6e8", "name": "p1rdt8204lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d61466da-7b42-4518-90f7-f4815488ce05"}}}}, {"uuid": "0a451f8e-953d-4a4d-8347-edad82693b2c", "name": "", "x": 38.66416826088575, "y": -122.58688392637725, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dc7fa312-1baf-4f23-925f-a281071183a6", "name": "p1rlv17402", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a451f8e-953d-4a4d-8347-edad82693b2c"}}}}, {"uuid": "4b26802d-e23c-4468-b2c3-580cea831428", "name": "", "x": 38.6664926486277, "y": -122.58749879976138, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ecf11723-eb6d-423c-ac0c-85fa2d1ba846", "name": "p1rdt8208lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4b26802d-e23c-4468-b2c3-580cea831428"}}}}, {"uuid": "4ac2c5c1-618e-4106-b26e-5c3773bf4c79", "name": "", "x": 38.666718636185976, "y": -122.58689226135496, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f147f7e5-33e8-430b-9822-715e772debb3", "name": "p1rlv17413", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ac2c5c1-618e-4106-b26e-5c3773bf4c79"}}}}, {"uuid": "f901d18c-7e76-4de4-83f3-504b150840d2", "name": "", "x": 38.6508349878355, "y": -122.52772270990391, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f1a593e3-4735-47d2-b893-dd2d07c3c47c", "name": "p1rdt8578lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f901d18c-7e76-4de4-83f3-504b150840d2"}}}}, {"uuid": "fa2bab8c-4741-4c89-a36e-0f401dc5f8f6", "name": "", "x": 38.6509409741122, "y": -122.52789042198899, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5a28b095-45f5-43ec-983b-c1de596d4cb5", "name": "p1rlv18362", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa2bab8c-4741-4c89-a36e-0f401dc5f8f6"}}}}, {"uuid": "54e5f769-3d1c-4b01-8a58-c3530ce25014", "name": "", "x": 38.65066839894964, "y": -122.52734059189255, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8d1c3d0a-9def-4516-8429-386f1d70f506", "name": "p1rlv18364", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "54e5f769-3d1c-4b01-8a58-c3530ce25014"}}}}, {"uuid": "3d133081-f320-481d-93db-a3b5dcc28d51", "name": "", "x": 38.650824008938194, "y": -122.52793715797524, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "408c825d-17ac-4aea-9fc7-fff420657fc7", "name": "p1rlv18367", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3d133081-f320-481d-93db-a3b5dcc28d51"}}}}, {"uuid": "fa1ac5d2-b7cb-453b-9242-5ea28ea7b3ab", "name": "", "x": 38.647860789632105, "y": -122.5254589040337, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "134bac3d-5b7e-48d7-950e-01e5b7d43852", "name": "p1rdt8583lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa1ac5d2-b7cb-453b-9242-5ea28ea7b3ab"}}}}, {"uuid": "d536c44b-825c-4165-812f-b5fa407dad21", "name": "", "x": 38.64817724906055, "y": -122.52638016767358, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "905e171c-13d7-4f8d-b88a-7501b2327d81", "name": "p1rlv18370", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d536c44b-825c-4165-812f-b5fa407dad21"}}}}, {"uuid": "a6f0e76a-a551-45f5-a544-955ccc0eb60d", "name": "", "x": 38.64706546256806, "y": -122.5262571069094, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a8ba1042-fcfd-47a8-aa0f-8b13618d3212", "name": "p1rdt8584lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a6f0e76a-a551-45f5-a544-955ccc0eb60d"}}}}, {"uuid": "7891f0b1-efd2-44fb-9612-2be3e5dd1ef6", "name": "", "x": 38.64750833323082, "y": -122.52657595427343, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "58792e8c-3ad9-45bb-ac47-01983cca2a2b", "name": "p1rlv18371", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7891f0b1-efd2-44fb-9612-2be3e5dd1ef6"}}}}, {"uuid": "ee4e0a8b-2d46-4187-a857-a2e71a918ff8", "name": "", "x": 38.66789379909343, "y": -122.62737431712556, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c8f14e6e-ee96-4ae9-86ba-4a07cf103b65", "name": "p1rdt10491lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ee4e0a8b-2d46-4187-a857-a2e71a918ff8"}}}}, {"uuid": "2655db2b-f896-45ca-817d-dba842af8f70", "name": "", "x": 38.66785523664377, "y": -122.62747399595972, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a86348e4-7573-4903-b223-90155579923e", "name": "p1rlv22745", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2655db2b-f896-45ca-817d-dba842af8f70"}}}}, {"uuid": "3acca42a-228d-405c-b242-24b9b408046c", "name": "", "x": 38.66771072023337, "y": -122.6273712914315, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ee8b6bab-9edd-4250-b57b-3a76b432fb54", "name": "p1rdm23269", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3acca42a-228d-405c-b242-24b9b408046c"}}}}, {"uuid": "e82104cd-1fd3-4a40-84ae-355f99fe8c59", "name": "", "x": 38.66773801158078, "y": -122.62745161373962, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "db05b7f0-d2a8-4876-876e-ef0e9b469580", "name": "p1rlv22758", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e82104cd-1fd3-4a40-84ae-355f99fe8c59"}}}}, {"uuid": "5b6968d5-f9b5-4ee7-adba-3b83bc1f93d0", "name": "", "x": 38.656528899791525, "y": -122.61592868327206, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "473520c7-0098-4bc2-a46f-07efd6c3759c", "name": "p1rdt8070", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5b6968d5-f9b5-4ee7-adba-3b83bc1f93d0"}}}}, {"uuid": "7bb0f297-562b-497d-b9ce-36499e5b1011", "name": "", "x": 38.6563269771708, "y": -122.61481494098487, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "862f3566-9443-4b82-8f05-c994581e131a", "name": "p1rdt8065", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7bb0f297-562b-497d-b9ce-36499e5b1011"}}}}, {"uuid": "5b97a273-c1db-4cad-ba97-ea0ec4645596", "name": "", "x": 38.65650356164319, "y": -122.61644600466717, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7f5fbb8b-0c32-4aa7-acaf-7ea2b5e56505", "name": "p1rdt8068", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5b97a273-c1db-4cad-ba97-ea0ec4645596"}}}}, {"uuid": "3e57a0ea-ffba-40e1-804e-eaa3a7897315", "name": "", "x": 38.663548423315845, "y": -122.60574012937602, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "691c1909-3b71-4e07-abf0-95aaabfa23bb", "name": "p1rdt8043", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e57a0ea-ffba-40e1-804e-eaa3a7897315"}}}}, {"uuid": "ed6aebf5-9450-4578-881d-cae98151a49d", "name": "", "x": 38.65907117917629, "y": -122.61161258790305, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cbafbe81-1649-4bae-b9af-c4b1757392f0", "name": "p1rdt8043-p1rdt8070x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ed6aebf5-9450-4578-881d-cae98151a49d"}}}}, {"uuid": "6c8fea95-a7aa-4e43-ab48-30f65042e891", "name": "", "x": 38.66743589391774, "y": -122.62597035336422, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ca19324f-0855-4633-be68-b16c872e196d", "name": "p1rdt10491-p1rdt8043x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c8fea95-a7aa-4e43-ab48-30f65042e891"}}}}, {"uuid": "99689df4-980e-4bb2-b002-ae9a37ffd539", "name": "", "x": 38.667852061856834, "y": -122.62736658421983, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4737e613-8cf5-45d7-a3f5-71af051ece4c", "name": "p1rdt10491", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "99689df4-980e-4bb2-b002-ae9a37ffd539"}}}}, {"uuid": "6499ec0f-5e4c-4c55-9d87-b9feec61c306", "name": "", "x": 38.666432664329825, "y": -122.59875236139737, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6378abd-969e-4ec8-93eb-2cc39cdb18eb", "name": "p1rdt8017", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6499ec0f-5e4c-4c55-9d87-b9feec61c306"}}}}, {"uuid": "f8c35a56-8487-4552-91de-996ae7e93a21", "name": "", "x": 38.665466700320124, "y": -122.60006059980222, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "feda8d99-6fae-4c6e-bf52-f87894687da5", "name": "p1rdt8017-p1rdt8043x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f8c35a56-8487-4552-91de-996ae7e93a21"}}}}, {"uuid": "b47e2761-7265-4eda-9f5e-916e5198314b", "name": "", "x": 38.67412513347839, "y": -122.57295162842586, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a09cdbca-4e7b-4d9a-b479-515074964171", "name": "p1rdt101-p1rdt8017x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b47e2761-7265-4eda-9f5e-916e5198314b"}}}}, {"uuid": "0d8f64aa-a831-414b-b33d-90920ccc73f2", "name": "", "x": 38.67372843812363, "y": -122.57642531522278, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b1aeba4b-536e-4067-a7a5-627470ae0711", "name": "p1rdt101-p1rdt8017xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0d8f64aa-a831-414b-b33d-90920ccc73f2"}}}}, {"uuid": "cb64d0c5-316b-4ef4-9fc4-06dc369727d9", "name": "", "x": 38.6667923442126, "y": -122.59769681955328, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8c1a4365-a594-48be-b138-aa6935c34481", "name": "p1rdt101-p1rdt8017xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb64d0c5-316b-4ef4-9fc4-06dc369727d9"}}}}, {"uuid": "6b0aaced-0cdb-4e3b-9ab8-ec56496f99ba", "name": "", "x": 38.67336800550842, "y": -122.57317812900477, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e61ce952-a643-45aa-a466-8aa15ecceb48", "name": "p1rdt108", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6b0aaced-0cdb-4e3b-9ab8-ec56496f99ba"}}}}, {"uuid": "cc9a67b6-79b9-4193-be24-d3b00a83c29d", "name": "", "x": 38.67409957836356, "y": -122.57299468560076, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2d8e5d83-cd9c-4527-9eef-6219c98dfe93", "name": "p1rdt101", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc9a67b6-79b9-4193-be24-d3b00a83c29d"}}}}, {"uuid": "cbcc0bc7-f2c6-4318-8fe8-f233849842d7", "name": "", "x": 38.673004812616185, "y": -122.57321304352497, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a4f100ee-0152-4e27-bf0e-2c7dea1537ad", "name": "p1rdt108-p1rdt93x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cbcc0bc7-f2c6-4318-8fe8-f233849842d7"}}}}, {"uuid": "80f718dd-80a7-4d45-98b2-65163070d903", "name": "", "x": 38.66653438838322, "y": -122.58750650935949, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8e2b4d77-2388-4897-86fe-06409fa9d222", "name": "p1rdt8208", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "80f718dd-80a7-4d45-98b2-65163070d903"}}}}, {"uuid": "c15f08e7-d9f7-403e-a6d8-3b883874c9fc", "name": "", "x": 38.6643277050057, "y": -122.58690202438763, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fa2342e6-2d40-424a-830c-a84af4632b6e", "name": "p1rdt8204", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c15f08e7-d9f7-403e-a6d8-3b883874c9fc"}}}}, {"uuid": "914c9442-7ee2-4f65-83b0-5589227565a3", "name": "", "x": 38.66696287663581, "y": -122.58784486869551, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0a761aef-a766-40e2-b8d7-e5a918cece18", "name": "p1rdt8190", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "914c9442-7ee2-4f65-83b0-5589227565a3"}}}}, {"uuid": "2b710d2f-ba85-48eb-b045-0a1e53513481", "name": "", "x": 38.66701682299843, "y": -122.58779500809689, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b860d5c-43e4-429e-b945-378020e3f926", "name": "p1rdt8190-p1rdt99xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2b710d2f-ba85-48eb-b045-0a1e53513481"}}}}, {"uuid": "45f324c1-53a0-4c45-84bb-8247a59540a3", "name": "", "x": 38.67081351738392, "y": -122.57529296188245, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6be75535-8c32-47ea-bad5-986daaed0921", "name": "p1rdt8190-p1rdt99x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "45f324c1-53a0-4c45-84bb-8247a59540a3"}}}}, {"uuid": "bd0ae6f7-68ed-42de-91dc-6e78b005e83b", "name": "", "x": 38.661326984313604, "y": -122.56975197710662, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ddf8f344-dcca-418d-850e-745f18d29660", "name": "p1rdt6121-p1rdt6123x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bd0ae6f7-68ed-42de-91dc-6e78b005e83b"}}}}, {"uuid": "1062a7cd-f594-4e16-9327-1fee2a297714", "name": "", "x": 38.6622273967057, "y": -122.56849554572818, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "17f807ba-6ad6-4fd9-9dd0-2c0bacea5b24", "name": "p1rdt6123", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1062a7cd-f594-4e16-9327-1fee2a297714"}}}}, {"uuid": "b1a6adaf-4169-404d-815c-821d17c42c72", "name": "", "x": 38.64782050495066, "y": -122.52536544340624, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d0747505-3381-4df0-a86e-3859acac8496", "name": "p1rdt8583-p1rdt8584x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b1a6adaf-4169-404d-815c-821d17c42c72"}}}}, {"uuid": "6fe736f3-597d-4832-a078-7f9462c6089a", "name": "", "x": 38.64710720626507, "y": -122.52626477895555, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2b601580-3091-4d8c-9718-1367c7ed385f", "name": "p1rdt8584", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6fe736f3-597d-4832-a078-7f9462c6089a"}}}}, {"uuid": "b74c66f5-7370-4363-aadb-c2963556dbbb", "name": "", "x": 38.67166598469829, "y": -122.57351010762986, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "092a9d51-a39c-4c05-905e-93fb1ae96ba2", "name": "p1rdt99", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b74c66f5-7370-4363-aadb-c2963556dbbb"}}}}, {"uuid": "c251ee2b-6d25-444e-84ed-7a550939f36b", "name": "", "x": 38.671869985546934, "y": -122.57338996774229, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e3d15ce6-878d-4dd5-bb33-5a0f6c11dded", "name": "p1rdt93-p1rdt99x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c251ee2b-6d25-444e-84ed-7a550939f36b"}}}}, {"uuid": "3c977c81-252d-4ac1-99d0-aac8f9743cbc", "name": "", "x": 38.67299050757224, "y": -122.5731622022605, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "900d49ce-4834-4f99-8d74-a5e9d2f63ea0", "name": "p1rdt93", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3c977c81-252d-4ac1-99d0-aac8f9743cbc"}}}}, {"uuid": "2bd1ce4a-a2d6-48af-9731-0ffbbac3c303", "name": "", "x": 38.66135292720275, "y": -122.56979464804087, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2390c014-d418-4d63-8438-529a036487db", "name": "p1rdt6121", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2bd1ce4a-a2d6-48af-9731-0ffbbac3c303"}}}}, {"uuid": "c7db02d4-5bc2-4f36-97d1-dfc8a8bdabb6", "name": "", "x": 38.66910358694126, "y": -122.57345236501213, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "49c9e6df-3490-4df1-88a0-8a83ca6cdd1e", "name": "p1rdt6121-p1rdt99x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c7db02d4-5bc2-4f36-97d1-dfc8a8bdabb6"}}}}, {"uuid": "697424df-cd5f-4975-84bb-60f564edf569", "name": "", "x": 38.650793244252796, "y": -122.52771503663553, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bb866499-9e9c-4394-bd76-d4320ba4934b", "name": "p1rdt8578", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "697424df-cd5f-4975-84bb-60f564edf569"}}}}, {"uuid": "35989896-71ba-4201-91dc-e454d727ee91", "name": "", "x": 38.660311758411375, "y": -122.56710257404733, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "af229e5c-a70f-4354-bddc-4a2698802741", "name": "p1rdt6121-p1rdt8578x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "35989896-71ba-4201-91dc-e454d727ee91"}}}}, {"uuid": "939671ba-5e71-4c33-a5b6-6ae2212229dc", "name": "", "x": 38.64784646411654, "y": -122.52540809020192, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dbb79e10-21ba-4f04-b8a3-0cf711d26d40", "name": "p1rdt8583", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "939671ba-5e71-4c33-a5b6-6ae2212229dc"}}}}, {"uuid": "1d950e8d-70ee-4f99-a69a-f6c10714f0b3", "name": "", "x": 38.648598745729544, "y": -122.52587175663075, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "975237e9-bd83-4a30-83ab-221eb7f85c65", "name": "p1rdt8578-p1rdt8583x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d950e8d-70ee-4f99-a69a-f6c10714f0b3"}}}}, {"uuid": "614fdcef-422b-4210-b725-39f50e5db0bf", "name": "635840a4-7200-4618-8afc-99b9529d4031_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_voltagesource_equipment", "type": "PhaseVoltageSourceEquipment", "serialized_type": "base"}}, "r0": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Resistance", "serialized_type": "quantity"}}}, "r1": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Resistance", "serialized_type": "quantity"}}}, "x0": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Reactance", "serialized_type": "quantity"}}}, "x1": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Reactance", "serialized_type": "quantity"}}}, "voltage": {"value": 39.838337182448036, "units": "kilovolt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "angle": {"value": 0.0, "units": "degree", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Angle", "serialized_type": "quantity"}}}}, {"uuid": "14c8c055-5866-4494-860e-192d157bb809", "name": "635840a4-7200-4618-8afc-99b9529d4031_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_voltagesource_equipment", "type": "PhaseVoltageSourceEquipment", "serialized_type": "base"}}, "r0": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Resistance", "serialized_type": "quantity"}}}, "r1": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Resistance", "serialized_type": "quantity"}}}, "x0": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Reactance", "serialized_type": "quantity"}}}, "x1": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Reactance", "serialized_type": "quantity"}}}, "voltage": {"value": 39.838337182448036, "units": "kilovolt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "angle": {"value": 120.0, "units": "degree", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Angle", "serialized_type": "quantity"}}}}, {"uuid": "00dfcdee-b9ee-489c-a339-b4615d17c496", "name": "635840a4-7200-4618-8afc-99b9529d4031_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_voltagesource_equipment", "type": "PhaseVoltageSourceEquipment", "serialized_type": "base"}}, "r0": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Resistance", "serialized_type": "quantity"}}}, "r1": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Resistance", "serialized_type": "quantity"}}}, "x0": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Reactance", "serialized_type": "quantity"}}}, "x1": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Reactance", "serialized_type": "quantity"}}}, "voltage": {"value": 39.838337182448036, "units": "kilovolt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "angle": {"value": 240.0, "units": "degree", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Angle", "serialized_type": "quantity"}}}}, {"uuid": "ff5789ac-35ae-461f-8d88-cd7b58b34ab3", "name": "635840a4-7200-4618-8afc-99b9529d4031", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.voltagesource_equipment", "type": "VoltageSourceEquipment", "serialized_type": "base"}}, "sources": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_voltagesource_equipment", "type": "PhaseVoltageSourceEquipment", "serialized_type": "composed_component", "uuid": "614fdcef-422b-4210-b725-39f50e5db0bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_voltagesource_equipment", "type": "PhaseVoltageSourceEquipment", "serialized_type": "composed_component", "uuid": "14c8c055-5866-4494-860e-192d157bb809"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_voltagesource_equipment", "type": "PhaseVoltageSourceEquipment", "serialized_type": "composed_component", "uuid": "00dfcdee-b9ee-489c-a339-b4615d17c496"}}}]}, {"uuid": "267037ac-94da-4162-9484-f2f5d9cab688", "name": "source", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_vsource", "type": "DistributionVoltageSource", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "574ab810-c1b0-4662-8c4d-f32ab6893a36"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.voltagesource_equipment", "type": "VoltageSourceEquipment", "serialized_type": "composed_component", "uuid": "ff5789ac-35ae-461f-8d88-cd7b58b34ab3"}}}}, {"uuid": "e5469e34-b4db-4115-9139-ffc60bb49bbd", "name": "546d6ea1-cd18-4228-8edd-9598526a92df_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.840334051658807, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.3948056193408553, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "67309e73-810a-4c78-8158-ce7710efe7e3", "name": "0de45f54-cece-4e94-844c-81772bee923e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e5469e34-b4db-4115-9139-ffc60bb49bbd"}}}]}, {"uuid": "d8d6bc4a-d96f-43ae-bc69-823255ae76bd", "name": "load_p1rlv10170_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02e86824-b793-4080-9401-c6995a365baf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "67309e73-810a-4c78-8158-ce7710efe7e3"}}}}, {"uuid": "20c0e7c7-8721-449c-8c78-09d4f3da035a", "name": "8ee826d6-19c9-4320-b5fa-c5423073ad16_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.840334051658807, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.3948056193408553, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4b2bfcd5-d8c2-4fcf-a9ef-c821a2fc7a47", "name": "7cd431cb-01ba-4354-b594-83a35144906b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "20c0e7c7-8721-449c-8c78-09d4f3da035a"}}}]}, {"uuid": "4299a3aa-ba1d-4f0a-832e-e4ee9347ae96", "name": "load_p1rlv10170_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02e86824-b793-4080-9401-c6995a365baf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4b2bfcd5-d8c2-4fcf-a9ef-c821a2fc7a47"}}}}, {"uuid": "129db834-e664-434f-8575-b55557c4d16d", "name": "3159695e-34c3-44b2-99ac-8f94ad58ec5f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5675771284059596, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.814222257775612, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1fa7a333-c682-4f9f-b838-214a1d8e9d1c", "name": "1c0a9cd1-4dfa-42e3-9507-6749ffbb8be3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "129db834-e664-434f-8575-b55557c4d16d"}}}]}, {"uuid": "b92a9605-b0ce-432e-98e8-89764b805b42", "name": "load_p1rlv10189_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58f2b2c3-4f6f-4fd2-abb9-42ff665692bd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1fa7a333-c682-4f9f-b838-214a1d8e9d1c"}}}}, {"uuid": "3b57b23f-b611-422d-8dfb-191cdc583f6f", "name": "0d6e89aa-c113-496d-b3b7-27aaa1bc6294_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5675771284059596, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.814222257775612, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5ed83898-2733-4cea-a50f-5d2f64738b3f", "name": "45b095f5-c1e1-4fd2-9c6f-b5c6cbd9d6fe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3b57b23f-b611-422d-8dfb-191cdc583f6f"}}}]}, {"uuid": "18684a60-bdcf-4ecb-b451-206191b5b387", "name": "load_p1rlv10189_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58f2b2c3-4f6f-4fd2-abb9-42ff665692bd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5ed83898-2733-4cea-a50f-5d2f64738b3f"}}}}, {"uuid": "b50974d8-7716-4e1f-a154-58141fe96159", "name": "07638998-4261-4040-9283-9a1ceeb6a17a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2859398622891502, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31064660144885853, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8262d88d-f6d6-4195-84e4-1ef29d502f23", "name": "c5ca30e9-1a76-466f-8aac-a8ac6cca0e2a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b50974d8-7716-4e1f-a154-58141fe96159"}}}]}, {"uuid": "f0b7de95-2441-47ba-b581-d2b2deff0a7c", "name": "load_p1rlv10262_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3317d7c2-2588-426d-91fc-3d765b932da6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8262d88d-f6d6-4195-84e4-1ef29d502f23"}}}}, {"uuid": "8a589d2d-8bb5-4a2d-a783-bae8c6be7f51", "name": "53619472-8b4a-4e99-8f1e-373fe1c283b8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2859398622891502, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31064660144885853, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d1078032-48da-45a9-9514-1bd009f80425", "name": "cae9ace2-76c6-4edb-a648-864e751d71b3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a589d2d-8bb5-4a2d-a783-bae8c6be7f51"}}}]}, {"uuid": "bd031773-5a92-44a8-b655-5ce11b5a4e7b", "name": "load_p1rlv10262_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3317d7c2-2588-426d-91fc-3d765b932da6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d1078032-48da-45a9-9514-1bd009f80425"}}}}, {"uuid": "993432e9-66d3-4fc9-affe-9f6530caeac7", "name": "91274f2d-6b69-4a31-922c-34d0fd405697_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.598111299087247, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3022070914124596, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5c9059e0-2b4a-4ed3-8029-709216e1ff3f", "name": "ee60a67d-83a4-4707-a5ce-a17eb9457a3b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "993432e9-66d3-4fc9-affe-9f6530caeac7"}}}]}, {"uuid": "efed8560-d920-49e0-8ae6-7fa50af9ebef", "name": "load_p1rlv10491_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f7116b9-96c1-42c8-850f-7787f5fd0f96"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5c9059e0-2b4a-4ed3-8029-709216e1ff3f"}}}}, {"uuid": "804be5d0-f940-44d3-87a2-1666ca6bfd99", "name": "8472f830-52fe-4e78-8f35-3650a707dfc3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.598111299087247, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3022070914124596, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e15b851c-dbf3-403b-9ce4-125e3739f110", "name": "5ae5f7ac-f7e3-44c4-81ed-2fd9c6cc7ceb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "804be5d0-f940-44d3-87a2-1666ca6bfd99"}}}]}, {"uuid": "c9f4b35b-fff0-42fe-9c01-70fec1a715f5", "name": "load_p1rlv10491_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f7116b9-96c1-42c8-850f-7787f5fd0f96"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e15b851c-dbf3-403b-9ce4-125e3739f110"}}}}, {"uuid": "2335485c-19cd-4605-9529-64275bc82eb0", "name": "a7ad5af2-a876-40d2-be51-500cc561015e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.388743979084916, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.03502268140121, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "867db88d-63b7-4bee-905f-784adcb5e721", "name": "3ef95a16-ca14-44b8-8a43-40eb5ab8cc7c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2335485c-19cd-4605-9529-64275bc82eb0"}}}]}, {"uuid": "0dc080b9-936f-4c3a-8e91-4be50f2719d3", "name": "load_p1rlv10521_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31f26b28-fc9d-4b3d-b204-cf40f3478c44"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "867db88d-63b7-4bee-905f-784adcb5e721"}}}}, {"uuid": "8418f1e2-1166-44ca-93f2-2f746cabc291", "name": "d8b85703-88cb-4147-9b12-71cc788bb321_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.388743979084916, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.03502268140121, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aa1ebe23-a640-41b4-bf0e-695a31d0e2b9", "name": "b4b52ff8-feab-429c-bfa7-67cfc1e912a9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8418f1e2-1166-44ca-93f2-2f746cabc291"}}}]}, {"uuid": "88b9c328-7f31-4d26-a036-a54f56ce234b", "name": "load_p1rlv10521_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31f26b28-fc9d-4b3d-b204-cf40f3478c44"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aa1ebe23-a640-41b4-bf0e-695a31d0e2b9"}}}}, {"uuid": "8c834a48-84b5-4861-bb74-d75985b72713", "name": "5d0dc6e4-fbab-47f9-8a91-231f6c1cdacb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0052757727111112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4127143879372469, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "88c22e57-29b7-47d0-b622-ffe83d964647", "name": "0ccc4eb5-9755-4d5f-a364-0f965120d933", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8c834a48-84b5-4861-bb74-d75985b72713"}}}]}, {"uuid": "9af6766f-1fd9-4825-a24d-8626cd72f11f", "name": "load_p1rlv10523_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35d47036-a044-4c67-b5b5-0006e2a3b68e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "88c22e57-29b7-47d0-b622-ffe83d964647"}}}}, {"uuid": "8e2f3d41-662e-4980-a1b7-c7fb900caf45", "name": "6647fe10-6588-4164-9eb3-fea25d2a9462_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0052757727111112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4127143879372469, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b8189c3a-08fd-4911-a1b5-f0955e23a3a3", "name": "cb7b10a1-ef90-490e-a741-057dbb9d5a98", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8e2f3d41-662e-4980-a1b7-c7fb900caf45"}}}]}, {"uuid": "5d074c7c-783a-49b5-bbf6-863562eb73a0", "name": "load_p1rlv10523_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35d47036-a044-4c67-b5b5-0006e2a3b68e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b8189c3a-08fd-4911-a1b5-f0955e23a3a3"}}}}, {"uuid": "61dccb8d-ca08-485b-a85d-1ddcd11916ad", "name": "88a2a0b3-fce5-4f48-bfa4-7b1781a741ff_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.346612792133217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8934968317135462, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0338a4f1-fc36-4a79-8794-79a666eb2c08", "name": "fa4c633e-4531-48d1-a321-07ff0c9e763c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "61dccb8d-ca08-485b-a85d-1ddcd11916ad"}}}]}, {"uuid": "92703db3-7c03-43fd-ad1e-f9cfeba4b985", "name": "load_p1rlv10538_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a302271d-4cf3-45ff-9308-b9cf31fbefa3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0338a4f1-fc36-4a79-8794-79a666eb2c08"}}}}, {"uuid": "98bcc0db-9132-4a3c-b610-06c2a350389a", "name": "325c85da-bcf2-4095-a07b-f0d830768108_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.346612792133217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8934968317135462, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ca6b885e-c8f9-4c05-959a-8d15c50227f0", "name": "d67af9d6-ac8e-411c-9161-2fdf6f6679fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "98bcc0db-9132-4a3c-b610-06c2a350389a"}}}]}, {"uuid": "b731739f-fa18-4fad-905c-87443cfce5d5", "name": "load_p1rlv10538_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a302271d-4cf3-45ff-9308-b9cf31fbefa3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ca6b885e-c8f9-4c05-959a-8d15c50227f0"}}}}, {"uuid": "6163aa2a-d4cd-4dfd-ad54-185653ab500b", "name": "561cc921-b931-499a-9b8b-b842a3b37e3b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.732212626630997, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.8695385943463294, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a968d13-c9e7-46a9-91eb-97e0d61a66b4", "name": "561cc921-b931-499a-9b8b-b842a3b37e3b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.732212626630997, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.8695385943463294, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "265d3447-d136-4cd0-89e8-91663f91a7fb", "name": "561cc921-b931-499a-9b8b-b842a3b37e3b_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.732212626630997, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.8695385943463294, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ce4815e4-79ce-4a08-8a1b-ea8a864d4c9b", "name": "1d264e18-a308-48d9-8e38-d4620f923977", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6163aa2a-d4cd-4dfd-ad54-185653ab500b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0a968d13-c9e7-46a9-91eb-97e0d61a66b4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "265d3447-d136-4cd0-89e8-91663f91a7fb"}}}]}, {"uuid": "5a1b9a31-aa33-4417-9163-777f1be8b93c", "name": "load_p1rlv10539", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08331744-08b7-455e-b2ca-284cae95fb06"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ce4815e4-79ce-4a08-8a1b-ea8a864d4c9b"}}}}, {"uuid": "4acb4341-939b-4101-99e7-6eabbbfe10dc", "name": "1b203d67-d092-48e6-9fdd-033bd70091ff_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3798783675992279, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6151141774255103, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "029b3287-e402-41d2-ba35-dc675176b103", "name": "16e47c63-28f8-404d-af33-fb21391635d6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4acb4341-939b-4101-99e7-6eabbbfe10dc"}}}]}, {"uuid": "02684642-c54a-4ad2-85bf-c0eac2537c9d", "name": "load_p1rlv10540_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4829cd2f-7e61-4386-89ce-89d77d5ef5cf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "029b3287-e402-41d2-ba35-dc675176b103"}}}}, {"uuid": "779f5336-f165-4153-927c-a3b56b0c95df", "name": "4c549c39-eef7-4182-949e-97c202c2c5cf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3798783675992279, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6151141774255103, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "36fa9d3b-a675-47fe-8787-cbff3d8847d9", "name": "936c33b0-831b-434b-b429-dc6b6e5a83fe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "779f5336-f165-4153-927c-a3b56b0c95df"}}}]}, {"uuid": "2be448aa-639b-445d-93b9-eff7ac15c311", "name": "load_p1rlv10540_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4829cd2f-7e61-4386-89ce-89d77d5ef5cf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "36fa9d3b-a675-47fe-8787-cbff3d8847d9"}}}}, {"uuid": "872c6067-a8d5-4cf8-9df4-5bffa0ff49f2", "name": "75df7eb9-d32f-44f3-bffe-0c74d23011a3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9115470716545817, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7511996531223851, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b4e1f0ad-c09e-4b3d-91a8-e3e50dcc5fa4", "name": "e09b0864-5e4c-4a3f-bdf7-c34e3e6c2884", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "872c6067-a8d5-4cf8-9df4-5bffa0ff49f2"}}}]}, {"uuid": "447fbe14-d0f5-428a-ae6e-897576c45644", "name": "load_p1rlv10544_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c722b89-fdaf-416f-863e-02b443375ba1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b4e1f0ad-c09e-4b3d-91a8-e3e50dcc5fa4"}}}}, {"uuid": "d8732fcd-8c59-44e7-a017-e1215105f5fa", "name": "72fe6248-d802-4be6-8a03-77d6d027095e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9115470716545817, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7511996531223851, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "443403d0-6584-4bf0-a96a-f0f8755d8610", "name": "8b01779b-6a18-45ef-9644-0f429d6aa12b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d8732fcd-8c59-44e7-a017-e1215105f5fa"}}}]}, {"uuid": "4c73c470-77cf-4169-81a9-d2e62d49ce9a", "name": "load_p1rlv10544_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c722b89-fdaf-416f-863e-02b443375ba1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "443403d0-6584-4bf0-a96a-f0f8755d8610"}}}}, {"uuid": "34640cc1-c224-4d24-b99f-215e00359092", "name": "fc449386-6b31-4ddc-b229-a11c4e93b3fc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6295328634326751, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9988748196040309, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e761bf5d-8dac-40fe-bcc1-784c02d7c9e0", "name": "0d32055b-85ed-43e6-84b0-ea0daf522bd5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "34640cc1-c224-4d24-b99f-215e00359092"}}}]}, {"uuid": "43ed04f3-eff1-4a13-8cf6-62a67d684189", "name": "load_p1rlv10563_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8a10822-398f-441e-a5ca-73303d832183"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e761bf5d-8dac-40fe-bcc1-784c02d7c9e0"}}}}, {"uuid": "2bb093c4-e0e8-4fbe-b20d-2c543a778bb4", "name": "882a7e93-5e51-4249-ad96-1a17e1d7aef4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6295328634326751, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9988748196040309, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ec28bff4-9338-43fc-be62-87fa847f6b55", "name": "1c446171-7668-4308-bfea-5de0daefc0d8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2bb093c4-e0e8-4fbe-b20d-2c543a778bb4"}}}]}, {"uuid": "1f8e033b-4c97-4409-a9ed-ef376cf47405", "name": "load_p1rlv10563_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8a10822-398f-441e-a5ca-73303d832183"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ec28bff4-9338-43fc-be62-87fa847f6b55"}}}}, {"uuid": "1f09440e-cd9a-4892-8523-67a089753aaa", "name": "f3ba15c3-6897-4cf9-b966-1be649810e54_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.140962173014189, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10805830108563602, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d6e738d1-f311-47c7-8ff0-3779b081757e", "name": "0f67960a-e395-41cb-a379-2cf8e66d43c4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1f09440e-cd9a-4892-8523-67a089753aaa"}}}]}, {"uuid": "63d2901e-e1f7-46b7-9244-31a4776e7c0a", "name": "load_p1rlv10573_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94677ede-fd5c-4fbb-bfcd-98cf67b56913"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d6e738d1-f311-47c7-8ff0-3779b081757e"}}}}, {"uuid": "4f079056-6c3e-4ff4-a67f-efe20d6a13e6", "name": "7b2273a6-6447-4fb9-916b-ff2a0a658219_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.140962173014189, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10805830108563602, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0aca7f90-a560-460a-9f18-8ba07af4701d", "name": "3aec8eb6-8ec5-4038-9e34-f5081eae467d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4f079056-6c3e-4ff4-a67f-efe20d6a13e6"}}}]}, {"uuid": "072eddd9-9ee0-4cee-894b-68a9ea4c645b", "name": "load_p1rlv10573_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94677ede-fd5c-4fbb-bfcd-98cf67b56913"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0aca7f90-a560-460a-9f18-8ba07af4701d"}}}}, {"uuid": "73e7c137-a605-4cb7-bbf3-26cdeed2315f", "name": "87f74108-c47a-4732-8a5e-ba596786e074_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6027984746974515, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12293402966163972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ba9cf4ad-f3fd-4227-a19b-2aaad62123f8", "name": "22278bf8-f8dd-4f1c-ab87-9b73b7dbe1d7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "73e7c137-a605-4cb7-bbf3-26cdeed2315f"}}}]}, {"uuid": "4f33ad95-2a70-4770-a098-910ca9f52b56", "name": "load_p1rlv10574_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b4caeee-6304-4a25-a7d8-44c6014b5e37"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ba9cf4ad-f3fd-4227-a19b-2aaad62123f8"}}}}, {"uuid": "875f2236-e580-4421-bef0-f41c0eed5036", "name": "d4a9c871-3f9d-48a9-a724-ec5889420a13_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6027984746974515, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12293402966163972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "98ae50de-25e8-45e5-9aaf-3f1a06befbc1", "name": "dd6ab7a6-3919-4a87-995c-03d757d7f8e2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "875f2236-e580-4421-bef0-f41c0eed5036"}}}]}, {"uuid": "f9a00871-20ba-4f21-bebb-33613bf841e2", "name": "load_p1rlv10574_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b4caeee-6304-4a25-a7d8-44c6014b5e37"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "98ae50de-25e8-45e5-9aaf-3f1a06befbc1"}}}}, {"uuid": "091bf3dc-4ce0-4c92-b4f3-148a0f482cdf", "name": "dc3fc21e-dadf-45ba-8bec-19f14fc3a3c7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.535252812300099, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.708042162201308, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "424df63a-d4c4-49df-9896-f4bf2b07c473", "name": "228ebb4b-92bf-41c6-9d2b-4a7c1797794f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "091bf3dc-4ce0-4c92-b4f3-148a0f482cdf"}}}]}, {"uuid": "cfbdf53b-5867-474e-b60c-f40634e804eb", "name": "load_p1rlv10576_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25141e20-0a65-4905-b37f-954ed1a8751c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "424df63a-d4c4-49df-9896-f4bf2b07c473"}}}}, {"uuid": "7019b336-5d5d-484f-b921-9e5aca1d3c6d", "name": "59fe0be2-26b2-41b7-bdc7-7ba3350faf0f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.535252812300099, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.708042162201308, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8cee5bc4-c540-4440-ad24-55b653fd412a", "name": "b4b37538-0702-4489-94ad-1451bdbccbff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7019b336-5d5d-484f-b921-9e5aca1d3c6d"}}}]}, {"uuid": "f9ccbd09-813c-4072-bc2f-1aa56b889574", "name": "load_p1rlv10576_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25141e20-0a65-4905-b37f-954ed1a8751c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8cee5bc4-c540-4440-ad24-55b653fd412a"}}}}, {"uuid": "ce073e85-7f43-43d1-88c2-155ddf7a246d", "name": "00f06c4c-ddc4-4abf-afb5-bdceb596c710_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.261177426225613, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7908181369947367, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a8f9af20-7f19-4bf7-be41-a37c69963df6", "name": "702b8ae1-6285-494d-b679-55db28da0e5f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ce073e85-7f43-43d1-88c2-155ddf7a246d"}}}]}, {"uuid": "32de3124-470c-493e-8a0b-1157ef1af7ae", "name": "load_p1rlv10582_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdfa726f-5606-4ae2-b358-ad664dd7b0e3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a8f9af20-7f19-4bf7-be41-a37c69963df6"}}}}, {"uuid": "f9edb153-baa9-45c1-a696-5e44278f86b3", "name": "ad721249-ca51-45d8-962e-0a9e773e5d9d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.261177426225613, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7908181369947367, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "baaa64b4-3737-4051-9f0b-9d3727462fde", "name": "44ff648c-5a1e-45c3-89bb-8ace748e5de5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f9edb153-baa9-45c1-a696-5e44278f86b3"}}}]}, {"uuid": "442c6a76-1f2b-444a-9201-70b55cf27e61", "name": "load_p1rlv10582_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdfa726f-5606-4ae2-b358-ad664dd7b0e3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "baaa64b4-3737-4051-9f0b-9d3727462fde"}}}}, {"uuid": "33441858-6598-49d0-8453-71c6d90501c5", "name": "1e4ff4e9-c297-4aa5-84e2-f849bcffb5d2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "506125d1-1fed-441c-a96c-ff7cc5ab005f", "name": "8a782648-1632-4447-8a78-89d4d790e3c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "33441858-6598-49d0-8453-71c6d90501c5"}}}]}, {"uuid": "b419a8f6-93e5-4c8f-96c2-6e7960421ba5", "name": "load_p1rlv10583_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0431d17-75da-48c1-965c-875f61b0e9bf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "506125d1-1fed-441c-a96c-ff7cc5ab005f"}}}}, {"uuid": "46ae0867-dcb5-467b-8c07-d3a5302c3791", "name": "010b32c2-c545-4787-be8e-2f7c02fb95ad_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b8dd710d-416d-4930-9f88-b0fefa62cea2", "name": "e09b0ffd-aa74-4154-815a-e46564fce253", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "46ae0867-dcb5-467b-8c07-d3a5302c3791"}}}]}, {"uuid": "9e6b3a5b-3f3a-4880-ba5f-dae0d358a4e7", "name": "load_p1rlv10583_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0431d17-75da-48c1-965c-875f61b0e9bf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b8dd710d-416d-4930-9f88-b0fefa62cea2"}}}}, {"uuid": "a71bb0d6-7cd5-4cb0-aa39-4b03fcbf501f", "name": "6e85531c-5724-434e-bf41-258885a0b74e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.283752349161772, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1583018658461228, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a14c57e3-8928-429f-b8b6-434759fd2792", "name": "05c4c798-47ad-4584-b26d-777b063fcd5b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a71bb0d6-7cd5-4cb0-aa39-4b03fcbf501f"}}}]}, {"uuid": "affed099-9528-466f-9ba6-f50f7bd56991", "name": "load_p1rlv10586_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfbe5665-c020-455a-addc-d3f9514735ed"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a14c57e3-8928-429f-b8b6-434759fd2792"}}}}, {"uuid": "706a7727-9c14-44bb-9f42-f5769b154fbf", "name": "0f2287e2-6648-4316-a7e5-c85a81a46ccb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.283752349161772, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1583018658461228, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "65400728-b7be-4d80-bb6e-68e381270709", "name": "50ffc628-e234-4147-8964-d3c900648e60", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "706a7727-9c14-44bb-9f42-f5769b154fbf"}}}]}, {"uuid": "aca6ee26-2121-4078-a1fb-7eefb2af7234", "name": "load_p1rlv10586_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfbe5665-c020-455a-addc-d3f9514735ed"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "65400728-b7be-4d80-bb6e-68e381270709"}}}}, {"uuid": "998df9b0-50aa-4706-962c-b6a9c63af559", "name": "d8a9d3c7-8558-4027-ab66-7f6ca44c0b08_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.580529910152944, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3492768846801997, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f740fd31-5393-4c25-9cbd-5143edc3f377", "name": "865924bd-36b9-4409-8ca2-1d232656ec43", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "998df9b0-50aa-4706-962c-b6a9c63af559"}}}]}, {"uuid": "98a2757d-3c5d-47f5-a5ef-a267cb357eac", "name": "load_p1rlv10589_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53019a8a-b453-4add-9d2d-e4ab380fce67"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f740fd31-5393-4c25-9cbd-5143edc3f377"}}}}, {"uuid": "c736f350-7e92-4bcd-a808-503bf3dded9c", "name": "8e8b7b9b-4a12-48fd-a14c-20c44555255a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.580529910152944, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3492768846801997, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "179147ef-6495-4bc7-9ace-5174b9ffd0fb", "name": "c488a22b-700a-4256-a5a1-a4d9e1d21a6e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c736f350-7e92-4bcd-a808-503bf3dded9c"}}}]}, {"uuid": "b467a724-c9b6-4c0a-90eb-b75a3fd0f403", "name": "load_p1rlv10589_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53019a8a-b453-4add-9d2d-e4ab380fce67"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "179147ef-6495-4bc7-9ace-5174b9ffd0fb"}}}}, {"uuid": "e0c1e9bf-a608-43ec-b3ab-ff05515704f1", "name": "30465b35-19b7-4740-949a-2d5f1389c11f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.781684048838155, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7643971440160673, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0924a091-904d-42f7-b649-d8c4e062b684", "name": "ec220ee0-75c1-431e-9f5d-98b007931647", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e0c1e9bf-a608-43ec-b3ab-ff05515704f1"}}}]}, {"uuid": "43b43c8c-05dc-4444-9fed-3c3eea1e50be", "name": "load_p1rlv10596_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aad9ea92-9403-4ac0-9aaf-7e845b8c7bb5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0924a091-904d-42f7-b649-d8c4e062b684"}}}}, {"uuid": "212866d9-892a-44ab-9d78-1fa02458a3cc", "name": "f82a8ffb-3899-42d7-8198-177451892f51_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.781684048838155, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7643971440160673, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "516ee468-42ac-4367-941a-45593dd976de", "name": "b737aa9d-6fdd-472a-913f-78c8fe79ed87", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "212866d9-892a-44ab-9d78-1fa02458a3cc"}}}]}, {"uuid": "7b7838ce-89c4-413f-9761-111972a4b000", "name": "load_p1rlv10596_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aad9ea92-9403-4ac0-9aaf-7e845b8c7bb5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "516ee468-42ac-4367-941a-45593dd976de"}}}}, {"uuid": "4d25b7f3-e1e0-432c-bbd2-20c4982bffda", "name": "b7d458c4-81f5-4535-9a34-c06bdafbc719_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.133667846972055, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2625504562375869, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "291e100a-66a8-41c0-bb8e-9d18f760f9dc", "name": "2aa56bbc-393b-4963-891e-67d320f18d6c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4d25b7f3-e1e0-432c-bbd2-20c4982bffda"}}}]}, {"uuid": "7fd0a1eb-8e77-42a0-8a43-1990b29e2e1a", "name": "load_p1rlv10600_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "feb19590-c5f4-4982-9e99-20599f08cfe7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "291e100a-66a8-41c0-bb8e-9d18f760f9dc"}}}}, {"uuid": "93c34184-8439-410b-ab1a-54995d21afe4", "name": "1d458fa6-b09d-4bc8-ade0-0eaf6f62856b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.133667846972055, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2625504562375869, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8afd019e-2169-40ea-b70e-02b9578356bb", "name": "207faf6b-8f69-40e4-97fe-33d345d76c58", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "93c34184-8439-410b-ab1a-54995d21afe4"}}}]}, {"uuid": "e6bf0bb1-8209-47b9-9304-84e1a3ec0e95", "name": "load_p1rlv10600_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "feb19590-c5f4-4982-9e99-20599f08cfe7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8afd019e-2169-40ea-b70e-02b9578356bb"}}}}, {"uuid": "b5dece36-50a7-4842-bbf9-9cdcf07baef7", "name": "8767fde3-ad7a-414e-bc9e-ca67510d2a2c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.35395787140957025, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.14845654114897794, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "71bb45c2-d377-4a99-a4d5-f04aab1c26a7", "name": "1a4c4159-647d-4a55-940a-3d3bc5b56df3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5dece36-50a7-4842-bbf9-9cdcf07baef7"}}}]}, {"uuid": "962db928-09f8-4d43-9e77-fd32dd920c61", "name": "load_p1rlv10610_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b91354e-ce50-44d0-a959-fa451bb9cf20"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "71bb45c2-d377-4a99-a4d5-f04aab1c26a7"}}}}, {"uuid": "3b307419-3523-499b-8ab5-3e84ec6d323b", "name": "bb104de1-36db-46bf-81e0-7ebfe6c1d871_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.35395787140957025, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.14845654114897794, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c328b7ae-4b82-457d-8a1a-9810e282362a", "name": "376a780a-f7e2-4b6a-9e1c-adbbc7cad426", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3b307419-3523-499b-8ab5-3e84ec6d323b"}}}]}, {"uuid": "295f6e77-8da3-43b6-8193-d01761e2adff", "name": "load_p1rlv10610_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b91354e-ce50-44d0-a959-fa451bb9cf20"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c328b7ae-4b82-457d-8a1a-9810e282362a"}}}}, {"uuid": "5a920664-46e5-44a4-abf9-38560768e114", "name": "fc0d786d-53e1-449d-9803-734d144740c8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9149869461814677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5767582022429075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "47fe32f7-b3b9-4ee4-902c-48cc953c93f6", "name": "e6cb8855-dec5-415f-911d-297d7831ccb9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5a920664-46e5-44a4-abf9-38560768e114"}}}]}, {"uuid": "3da235eb-7577-4aab-8863-c8474cb6de00", "name": "load_p1rlv10615_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b175fcb-d1ee-44eb-8f89-826e40c5db1d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "47fe32f7-b3b9-4ee4-902c-48cc953c93f6"}}}}, {"uuid": "4d15b95c-82d8-4b91-aeb5-50fbe216e6de", "name": "f61c42da-6a48-4219-ab9b-8fc1f38764dd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9149869461814677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5767582022429075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8c4eedf7-f50b-42fd-8871-6790d0feb8a4", "name": "c9fda510-ad07-4e41-a244-893e99990fa6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4d15b95c-82d8-4b91-aeb5-50fbe216e6de"}}}]}, {"uuid": "6601651a-f399-4530-9b0b-c9fd05796b8e", "name": "load_p1rlv10615_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b175fcb-d1ee-44eb-8f89-826e40c5db1d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8c4eedf7-f50b-42fd-8871-6790d0feb8a4"}}}}, {"uuid": "2b7045b6-1362-42cf-bb6c-31cf6d4cae79", "name": "ed9bb46e-4447-4388-b0d3-1b09ad2dc42d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7464189326227366, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4011494318939581, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bec56e7a-528d-4b92-b5d0-486b1cbee7fc", "name": "a26888a3-858e-406b-ac7a-2ab68649b0c6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2b7045b6-1362-42cf-bb6c-31cf6d4cae79"}}}]}, {"uuid": "236e5d7e-1f9a-461d-844a-39414ced353d", "name": "load_p1rlv10616_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a5717e0-080e-46ae-918a-64fe4fcba5d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bec56e7a-528d-4b92-b5d0-486b1cbee7fc"}}}}, {"uuid": "4e4ad82d-6794-4073-ac45-9bf871ccf4c6", "name": "ce82cb31-9d2e-498a-a992-9599980183e2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7464189326227366, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4011494318939581, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a2a28822-0c17-4424-bb12-be4aa4b6af2a", "name": "24e55c3b-f642-4d33-84ba-33e0d4172e30", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4e4ad82d-6794-4073-ac45-9bf871ccf4c6"}}}]}, {"uuid": "43c97500-210e-4c50-abff-6d9608e600f9", "name": "load_p1rlv10616_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a5717e0-080e-46ae-918a-64fe4fcba5d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a2a28822-0c17-4424-bb12-be4aa4b6af2a"}}}}, {"uuid": "463f6149-b5d4-438f-a16d-4586f0bc0a43", "name": "422be16a-bf20-40ce-ad49-3394e9c866a2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.316539553342243, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9980015331306656, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d6cd3808-bd69-4b1c-a105-5654fa60cf31", "name": "91573b38-6c73-490f-82a5-e86402cf9f87", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "463f6149-b5d4-438f-a16d-4586f0bc0a43"}}}]}, {"uuid": "29eea145-22f9-4150-94ad-3764b540ef65", "name": "load_p1rlv10621_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "374d5417-b2c4-4d16-9b91-d2f519921fd8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d6cd3808-bd69-4b1c-a105-5654fa60cf31"}}}}, {"uuid": "1644862a-e0b2-4ebb-830d-5aa02ef2083c", "name": "029f2c31-f226-4c23-bfc7-08d84532d0e7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.316539553342243, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9980015331306656, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0d6655f1-c352-4e7b-980a-9045ce071e1e", "name": "a1e08948-18d1-4591-9457-112ac5261a7e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1644862a-e0b2-4ebb-830d-5aa02ef2083c"}}}]}, {"uuid": "2ed5b3ea-f3ae-475e-8aa6-c5bfe5aa1b73", "name": "load_p1rlv10621_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "374d5417-b2c4-4d16-9b91-d2f519921fd8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0d6655f1-c352-4e7b-980a-9045ce071e1e"}}}}, {"uuid": "c31478e6-d929-4e98-b045-c71b4087ad9e", "name": "c06ea238-dd56-4f76-a18a-9b96099385f1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.45600682921886, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9975893759791478, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7b0fcda8-4fd9-4888-a3c8-7a064f3a0514", "name": "20858e21-f5be-4bc2-a069-a8068e7695f4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c31478e6-d929-4e98-b045-c71b4087ad9e"}}}]}, {"uuid": "9ee800d6-2926-45c5-b6d4-172a40ee6b6e", "name": "load_p1rlv10627_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32406d7d-51f9-4c16-900b-526985e5f62b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7b0fcda8-4fd9-4888-a3c8-7a064f3a0514"}}}}, {"uuid": "8d18bbd5-8fcc-4978-8b60-29e2529c0513", "name": "6ae0e2e9-df9d-4148-97f8-233de83aa4f4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.45600682921886, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9975893759791478, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4b6b3d03-cac6-4782-b4c3-d9055a264d8b", "name": "db365dd3-dfa0-4c92-9bfc-e5963b6beced", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8d18bbd5-8fcc-4978-8b60-29e2529c0513"}}}]}, {"uuid": "a2c989ea-ede9-4302-b016-020257901a81", "name": "load_p1rlv10627_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32406d7d-51f9-4c16-900b-526985e5f62b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4b6b3d03-cac6-4782-b4c3-d9055a264d8b"}}}}, {"uuid": "653ced00-1a70-4461-a7f6-a46782d611fb", "name": "b0d67803-8e00-442d-b29d-be88928222a0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.625789834877447, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.7705314525486966, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f000b9e4-f294-460c-9c34-682dee4dd32f", "name": "8089d052-21f9-42c0-a786-82669cbf06ec", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "653ced00-1a70-4461-a7f6-a46782d611fb"}}}]}, {"uuid": "7bbb89a7-837a-40c9-81e6-6140afcbb9bc", "name": "load_p1rlv10629_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e183b3e8-d995-4f1e-baee-8d9d4add157e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f000b9e4-f294-460c-9c34-682dee4dd32f"}}}}, {"uuid": "c75500b4-b35d-407d-8f47-15b6ddee22c7", "name": "6a8d26b5-3a9c-429a-9e31-330ff08e2951_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.625789834877447, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.7705314525486966, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e561abf6-354f-47f3-b5b8-2822f6d8891b", "name": "9627e5cb-4670-4bea-8f37-6b4ac968697f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c75500b4-b35d-407d-8f47-15b6ddee22c7"}}}]}, {"uuid": "d30485b2-f695-4972-b2a0-8205cb6a63c6", "name": "load_p1rlv10629_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e183b3e8-d995-4f1e-baee-8d9d4add157e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e561abf6-354f-47f3-b5b8-2822f6d8891b"}}}}, {"uuid": "0be7dab3-4ef7-4396-908e-c67399cca48a", "name": "bdcfe216-985a-423d-a716-8996ebdea531_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.125662061080136, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6733739749908499, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "28e783ef-c07f-4016-a491-53d49ddc21c8", "name": "26f86049-1b09-4339-ac49-8d0f10195020", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0be7dab3-4ef7-4396-908e-c67399cca48a"}}}]}, {"uuid": "09da0e23-f708-49f8-b813-bda8c90d15ae", "name": "load_p1rlv10630_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d60a935-dc9b-48ea-8ee7-9b682452035e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "28e783ef-c07f-4016-a491-53d49ddc21c8"}}}}, {"uuid": "c647e0fd-2e92-431a-8bb0-efebf3669424", "name": "b698fe6e-a967-423a-be37-144d8a5edea4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.125662061080136, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6733739749908499, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b71ca818-e973-4c59-9900-3bf0adb156fa", "name": "314aeea4-6250-4fa3-a96c-542ebc6e63f0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c647e0fd-2e92-431a-8bb0-efebf3669424"}}}]}, {"uuid": "5785d1c0-ba23-47eb-8707-a652c3394c89", "name": "load_p1rlv10630_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d60a935-dc9b-48ea-8ee7-9b682452035e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b71ca818-e973-4c59-9900-3bf0adb156fa"}}}}, {"uuid": "28b97377-d18d-4b60-9fca-e275e912c1c0", "name": "1eb51cbf-a614-4010-8d85-3031944396ef_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4699462180170992, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3815978523472859, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a04d5ba8-580f-4c23-afea-273c028b13a0", "name": "3ca967da-a3b3-44f3-a92f-2c7122f74989", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "28b97377-d18d-4b60-9fca-e275e912c1c0"}}}]}, {"uuid": "bb0803a9-ffed-4930-85ac-23fc778bea77", "name": "load_p1rlv10634_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3184f056-3b5f-403d-86a0-f9b28d6bb3e3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a04d5ba8-580f-4c23-afea-273c028b13a0"}}}}, {"uuid": "a7f4f6a8-df1c-44b1-9861-e21c9ec35731", "name": "9b69478f-847b-4ba5-9717-b8f663214aff_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4699462180170992, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3815978523472859, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "955bb2fc-75c9-456e-b65a-14916d6ced7b", "name": "2527f77e-53d9-412a-a32a-f3ea5d666ff1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a7f4f6a8-df1c-44b1-9861-e21c9ec35731"}}}]}, {"uuid": "b95dbc99-087a-46b2-bee8-c253dafd753a", "name": "load_p1rlv10634_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3184f056-3b5f-403d-86a0-f9b28d6bb3e3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "955bb2fc-75c9-456e-b65a-14916d6ced7b"}}}}, {"uuid": "a027f1ba-5e36-4e14-8867-e8750b9b3e88", "name": "77d960dd-6e4b-4835-af96-4ff160700260_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.444725768387703, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6902267912659802, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "751a9fe0-cc15-4d54-976f-9c9b44796aa8", "name": "f869e91b-9bbd-41eb-b0d9-b723b1f74a78", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a027f1ba-5e36-4e14-8867-e8750b9b3e88"}}}]}, {"uuid": "074c693a-da67-459d-b817-3848a9649671", "name": "load_p1rlv10637_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9510bd0-2bba-4522-bfbe-20b94ea400b6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "751a9fe0-cc15-4d54-976f-9c9b44796aa8"}}}}, {"uuid": "70233a64-93d7-48a5-a06f-0600b5583265", "name": "97d43e0e-f26c-4fdc-ba4f-dbe0fac30736_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.444725768387703, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6902267912659802, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e046118c-7973-4191-a90f-8d40c5b13230", "name": "da65b232-5e9a-486f-a95b-08db42c934d3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "70233a64-93d7-48a5-a06f-0600b5583265"}}}]}, {"uuid": "78a39f4f-3259-49ea-a016-d0b6b770a82a", "name": "load_p1rlv10637_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9510bd0-2bba-4522-bfbe-20b94ea400b6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e046118c-7973-4191-a90f-8d40c5b13230"}}}}, {"uuid": "fadd79c0-580a-4d5e-9b5e-4da9d0191025", "name": "421e5657-d3b4-4c77-910e-a3470738ed61_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.639205904339139, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.495473092652384, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "296cc9cb-beef-41c6-ae8e-7d039b1b7402", "name": "ca951ebf-49ea-4e9c-926c-27e69045a428", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fadd79c0-580a-4d5e-9b5e-4da9d0191025"}}}]}, {"uuid": "83f977da-d0de-4535-baeb-367c8d9a3bed", "name": "load_p1rlv10641_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73ada6ad-ace7-46c1-80f7-2cb33cf4cdb3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "296cc9cb-beef-41c6-ae8e-7d039b1b7402"}}}}, {"uuid": "6244ef9d-3ee0-4a79-a3cf-e130b5de1618", "name": "082e46e7-c3cd-4225-8e60-096b9eb9a590_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.639205904339139, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.495473092652384, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "521f0d48-d008-471b-b45d-f7bf007a4ceb", "name": "ca87f831-2281-423e-803b-1aac098aaabb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6244ef9d-3ee0-4a79-a3cf-e130b5de1618"}}}]}, {"uuid": "6bb625d2-9233-43f7-8321-cfc6b33e6e72", "name": "load_p1rlv10641_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73ada6ad-ace7-46c1-80f7-2cb33cf4cdb3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "521f0d48-d008-471b-b45d-f7bf007a4ceb"}}}}, {"uuid": "f91053fa-fba9-4b1a-94f3-b5dfda7e789f", "name": "55e3c28f-a550-42dc-b7cc-cb2f5f0dddfd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5996895391512607, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5332968923160806, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "da312d03-f181-4ea8-8476-b4e00dc50cb3", "name": "67cf474e-c021-428e-a983-8816bde7e8f8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f91053fa-fba9-4b1a-94f3-b5dfda7e789f"}}}]}, {"uuid": "e3969318-5b8f-4511-815b-c97286011e74", "name": "load_p1rlv10663_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8198c1c5-67e0-49b9-b11a-1f266f7f4bcb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "da312d03-f181-4ea8-8476-b4e00dc50cb3"}}}}, {"uuid": "6957f6ed-5631-42d6-9d60-cee07aa633d1", "name": "a2574217-f0bc-401c-aa12-2fe1c5ab5bb8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5996895391512607, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5332968923160806, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "85f0f261-6c1b-4794-ac26-c0f8f6be3265", "name": "da6eba67-b155-4618-ae2b-bf28e68e16c8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6957f6ed-5631-42d6-9d60-cee07aa633d1"}}}]}, {"uuid": "90ca281a-a8a7-4109-9b92-b7053ff76551", "name": "load_p1rlv10663_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8198c1c5-67e0-49b9-b11a-1f266f7f4bcb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "85f0f261-6c1b-4794-ac26-c0f8f6be3265"}}}}, {"uuid": "364ef7a1-6b22-425f-aa38-1667cc9652de", "name": "b02ac72c-6bab-4491-a7df-9856c068a576_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9149869461814677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5767582022429075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "12c2a122-0ec2-4129-90ee-9a330e839fb7", "name": "a142bbc2-148a-4fa0-be13-8a785682e3e2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "364ef7a1-6b22-425f-aa38-1667cc9652de"}}}]}, {"uuid": "e5b3e471-5f92-44ad-b659-16e3ab78dcf4", "name": "load_p1rlv10720_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3d48c0e-704d-4205-94a2-ee74be7ae350"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "12c2a122-0ec2-4129-90ee-9a330e839fb7"}}}}, {"uuid": "2ebeaab4-4842-4216-bd44-71dc5c2a7f6f", "name": "c7a07059-5ecf-411b-bee2-5ceb38f53633_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9149869461814677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5767582022429075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "41144dbe-6edf-48e6-931c-82121205ff38", "name": "212c5a0a-514f-4b2c-8912-4cef4b7adb80", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2ebeaab4-4842-4216-bd44-71dc5c2a7f6f"}}}]}, {"uuid": "d4f4e6d2-0731-455b-a58f-11e4d5d1b78e", "name": "load_p1rlv10720_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3d48c0e-704d-4205-94a2-ee74be7ae350"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "41144dbe-6edf-48e6-931c-82121205ff38"}}}}, {"uuid": "7049ada4-9114-4342-95bf-162266ecb2ba", "name": "209d18ad-3da4-4a0a-a18d-139fd7eff92e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.459276697523187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8425022918187992, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b16a6e95-c8f5-4782-94af-ed256de9d106", "name": "bb9c6d31-7bb7-4c8a-b7fc-eb53006db484", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7049ada4-9114-4342-95bf-162266ecb2ba"}}}]}, {"uuid": "a45093a1-aeb2-4aad-9a1c-57eef425994a", "name": "load_p1rlv10955_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75dbf8f0-4cb6-49b7-a2a5-f98e9ff4b8df"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b16a6e95-c8f5-4782-94af-ed256de9d106"}}}}, {"uuid": "da9d1374-3cb5-497a-97ba-27c9750ad746", "name": "0730f85a-c922-453d-bd82-9ee41aa7376d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.459276697523187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8425022918187992, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "08eb6627-ce4a-4673-957c-3df6796e63f0", "name": "b114394d-af7c-435f-ad7a-d1779837681a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "da9d1374-3cb5-497a-97ba-27c9750ad746"}}}]}, {"uuid": "d03d68b7-65eb-4249-be52-dd2a1dbe7650", "name": "load_p1rlv10955_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75dbf8f0-4cb6-49b7-a2a5-f98e9ff4b8df"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "08eb6627-ce4a-4673-957c-3df6796e63f0"}}}}, {"uuid": "f40aa2e5-798f-468f-93f9-958f2ae92bfd", "name": "811e6f6f-9ece-4150-80f3-983552fe8aac_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.42648220197083947, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17627708866943506, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e8a38e5e-7db6-4ecb-b58c-9dcaac9f11eb", "name": "71370420-00b4-4479-aee6-1c11890b72a5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f40aa2e5-798f-468f-93f9-958f2ae92bfd"}}}]}, {"uuid": "e5e82ab0-0cc3-4445-a080-eff62f94cd34", "name": "load_p1rlv11048_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a8fc823-6fe8-4a3b-9437-68aa751f5e3b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e8a38e5e-7db6-4ecb-b58c-9dcaac9f11eb"}}}}, {"uuid": "1013b4ee-68cb-4342-936f-ce6ebcddd288", "name": "b1fd9cc5-31c7-4176-b403-2656e3c2ce7a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.42648220197083947, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17627708866943506, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b678eeac-b15d-4766-8549-1eb6d5dc61bf", "name": "474536a9-ccf9-4eb4-9c23-35857083a349", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1013b4ee-68cb-4342-936f-ce6ebcddd288"}}}]}, {"uuid": "65b91a42-c72a-48d4-a306-71c83189ddca", "name": "load_p1rlv11048_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a8fc823-6fe8-4a3b-9437-68aa751f5e3b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b678eeac-b15d-4766-8549-1eb6d5dc61bf"}}}}, {"uuid": "8bb152c5-aaf8-40a7-8604-4360a5122b95", "name": "e31634b5-7017-47ab-b867-88b81e3a7163_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0788570276665777, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5949433355568994, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cf79dcb8-43f9-49d0-ab1e-f6e5cd137ec8", "name": "ea8a6cc2-20d2-42ad-a5cb-78d22731cb1c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8bb152c5-aaf8-40a7-8604-4360a5122b95"}}}]}, {"uuid": "ee8dcbf3-9e3a-431f-9108-40418a72d162", "name": "load_p1rlv11380_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f949a06a-817e-4666-95bb-9536ce06a694"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cf79dcb8-43f9-49d0-ab1e-f6e5cd137ec8"}}}}, {"uuid": "9fb0c3ac-d337-4dde-bedc-2f4bbba5ddef", "name": "f5c2b463-2dea-4336-8db0-a1001296e30a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0788570276665777, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5949433355568994, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5508212d-10cb-4e84-a89a-a39c0ba9e6e7", "name": "5db1c0a2-9f61-413e-b9fc-253e73f7889b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9fb0c3ac-d337-4dde-bedc-2f4bbba5ddef"}}}]}, {"uuid": "2dcd8ef1-01fd-44a8-af9e-6a40ebde70ab", "name": "load_p1rlv11380_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f949a06a-817e-4666-95bb-9536ce06a694"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5508212d-10cb-4e84-a89a-a39c0ba9e6e7"}}}}, {"uuid": "f11640f5-490c-4a9d-adbe-3a2bddcc1d95", "name": "630809d5-43e2-4522-b987-732d50a76bca_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.122083974307247, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.832996158964583, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "278ca58d-0aec-48ce-8f6d-022a2552ce18", "name": "ae7fadf0-a2dc-452a-a866-31b4daec1911", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f11640f5-490c-4a9d-adbe-3a2bddcc1d95"}}}]}, {"uuid": "34642993-ddc9-4c08-bf35-b04592e73168", "name": "load_p1rlv11384_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0c23aea-471f-4d10-9500-1bc14a67d7e7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "278ca58d-0aec-48ce-8f6d-022a2552ce18"}}}}, {"uuid": "360fefe8-8b88-4807-aa47-17a5de0df06d", "name": "d0ae83c6-a7c4-4e1a-95e5-bebea8ece424_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.122083974307247, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.832996158964583, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3bb00d31-4128-4f55-bdd8-9a989ab63a16", "name": "cd66eb38-760d-4dac-9177-b9385426979f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "360fefe8-8b88-4807-aa47-17a5de0df06d"}}}]}, {"uuid": "1431994c-a7e8-4e06-8ba2-4384f422d5b7", "name": "load_p1rlv11384_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0c23aea-471f-4d10-9500-1bc14a67d7e7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3bb00d31-4128-4f55-bdd8-9a989ab63a16"}}}}, {"uuid": "526a60db-5260-4cfe-a3d6-ce7cbc422a6b", "name": "cbaffa95-fa01-45a7-99ef-34477a88115a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 10.509020108523046, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.6522347064707315, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "79136e75-b2b8-4bd4-9360-0d672af1e684", "name": "55cb41d2-e75a-414e-8893-9f575d733c50", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "526a60db-5260-4cfe-a3d6-ce7cbc422a6b"}}}]}, {"uuid": "0cf0d892-3e55-4a93-a396-6b5d00cba278", "name": "load_p1rlv11385_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2115e8bb-fe49-49ad-8687-68feca212557"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "79136e75-b2b8-4bd4-9360-0d672af1e684"}}}}, {"uuid": "b2722973-8fe5-41d6-856b-01957ca2efb6", "name": "4c8dfd26-9575-44c2-8877-ec3dceddecec_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 10.509020108523046, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.6522347064707315, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c3a4d236-5526-4eaf-b69c-81f9f7b57cb6", "name": "eb107080-b20d-42c3-9e00-87dc33942c0e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b2722973-8fe5-41d6-856b-01957ca2efb6"}}}]}, {"uuid": "899f5896-8be0-4757-b0be-e3235ceff34b", "name": "load_p1rlv11385_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2115e8bb-fe49-49ad-8687-68feca212557"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c3a4d236-5526-4eaf-b69c-81f9f7b57cb6"}}}}, {"uuid": "98be4d9c-2302-41b6-9f5b-4124b7bedc5b", "name": "be52d5eb-3fdd-4f36-bc38-914bdf52b39f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.480517361983766, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0183082338731784, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e52315c8-e7e3-4682-8066-90ef82614883", "name": "0259a1c5-11af-4e90-a192-7575b8ccd45d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "98be4d9c-2302-41b6-9f5b-4124b7bedc5b"}}}]}, {"uuid": "4c2cd8dc-dc30-464f-a4f6-ae32fbbd247e", "name": "load_p1rlv11386_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f512d86-c9d9-4f58-9d5a-418d0732dc94"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e52315c8-e7e3-4682-8066-90ef82614883"}}}}, {"uuid": "9efa0853-fb2f-400c-ad76-17bc96185208", "name": "2d808018-f753-4122-8b76-c102272718fc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.480517361983766, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0183082338731784, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "78a80a75-a6a5-4450-b3a2-26efb704dc06", "name": "6a48081b-2edc-4ef6-96ff-51221e6a3bb5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9efa0853-fb2f-400c-ad76-17bc96185208"}}}]}, {"uuid": "f3b9c812-99d0-42c0-aaba-a48a0440d18c", "name": "load_p1rlv11386_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f512d86-c9d9-4f58-9d5a-418d0732dc94"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "78a80a75-a6a5-4450-b3a2-26efb704dc06"}}}}, {"uuid": "449a0c3d-1ba5-4099-9a54-1e94666184c9", "name": "16305d34-b9f3-4562-b126-f1a81d200b85_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4651344294517608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7736313908316925, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e7421110-4b71-4cca-9a89-108b52acf66b", "name": "16ac7d63-c464-4a44-91d6-7f7731be9d2b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "449a0c3d-1ba5-4099-9a54-1e94666184c9"}}}]}, {"uuid": "18607566-7803-4c38-875a-dcd43eb95cda", "name": "load_p1rlv11387_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbca8c57-0da4-4368-9821-7a9ca4282173"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e7421110-4b71-4cca-9a89-108b52acf66b"}}}}, {"uuid": "28751ce9-4f0f-43d8-a5a6-82b259be16d2", "name": "048de35a-8050-4d9a-99e1-996a10b8d873_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4651344294517608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7736313908316925, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "46cf857e-b861-4c96-9ddd-8f93f3999ff3", "name": "62942fa3-ff93-4763-b6e4-7e47e0ee32a5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "28751ce9-4f0f-43d8-a5a6-82b259be16d2"}}}]}, {"uuid": "242d0f50-b01f-465a-b6ad-42e3957d6adc", "name": "load_p1rlv11387_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbca8c57-0da4-4368-9821-7a9ca4282173"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "46cf857e-b861-4c96-9ddd-8f93f3999ff3"}}}}, {"uuid": "65dcd61c-606d-40c5-ac84-5c883bfd958a", "name": "7e0228c2-e3a9-4eb2-9609-4c43c4c479a4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4359784649582454, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.14838741475370543, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b35b4c6e-6f59-4eff-bcaa-d55880e1a26c", "name": "448c1537-1044-4341-8cc4-17303fdc01f6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "65dcd61c-606d-40c5-ac84-5c883bfd958a"}}}]}, {"uuid": "061ac5e1-4491-4054-a774-49521eab7009", "name": "load_p1rlv11388_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12377bf0-f258-4c29-ab26-e938c95ee25c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b35b4c6e-6f59-4eff-bcaa-d55880e1a26c"}}}}, {"uuid": "4c928ce3-4607-4184-a739-4aec1d7d889a", "name": "2631c714-8f91-4974-becb-b4af853a819c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4359784649582454, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.14838741475370543, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bcbddbf6-2fa2-44d7-8332-a0de0780b2c5", "name": "8b212604-4f4d-4843-a575-054512258d30", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4c928ce3-4607-4184-a739-4aec1d7d889a"}}}]}, {"uuid": "8a4b10c5-a6db-4ed7-8e35-6f998a22b4ae", "name": "load_p1rlv11388_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12377bf0-f258-4c29-ab26-e938c95ee25c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bcbddbf6-2fa2-44d7-8332-a0de0780b2c5"}}}}, {"uuid": "79d552d3-cee0-4a5c-b1a2-75be1d6a51c7", "name": "3bdb2f3f-9a78-4cc3-a63c-8cf570881f21_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5261964028176471, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5335215898246958, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7a49efe3-5daa-47c4-815e-2716df97977c", "name": "5fdfa4f1-eddf-4d3d-b9d7-0e9b2936dc09", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "79d552d3-cee0-4a5c-b1a2-75be1d6a51c7"}}}]}, {"uuid": "4ddb8c43-6e0c-4309-8132-cca83f8e4659", "name": "load_p1rlv11390_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b6420b1-3456-42fc-9266-c2b84e063cec"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7a49efe3-5daa-47c4-815e-2716df97977c"}}}}, {"uuid": "44b3e1b7-6f21-40fb-90f8-ada5d654828f", "name": "b0bbc030-b3ae-48cb-add4-c76f9579a136_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5261964028176471, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5335215898246958, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a1a95b33-a327-433e-a614-fe431f7fa246", "name": "592346aa-cb58-403e-b561-9fd691bdeddb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "44b3e1b7-6f21-40fb-90f8-ada5d654828f"}}}]}, {"uuid": "8b62b715-2222-4d0f-bb32-eb15d0362481", "name": "load_p1rlv11390_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b6420b1-3456-42fc-9266-c2b84e063cec"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a1a95b33-a327-433e-a614-fe431f7fa246"}}}}, {"uuid": "559142c0-923c-48cb-a663-08acf9b99abe", "name": "edd46b4f-039e-4197-bea5-a0a193e9034c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.056520022279634, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8635401886215074, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "755f07e7-916c-4a53-8b8e-fdbe8a86ed7e", "name": "8800987f-4611-48c6-be6e-61646d7a93f9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "559142c0-923c-48cb-a663-08acf9b99abe"}}}]}, {"uuid": "2f3b07f5-6d3b-47c6-b03f-62a581a26356", "name": "load_p1rlv11392_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e740a352-ac8f-4ae2-ace3-254fccd7f96f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "755f07e7-916c-4a53-8b8e-fdbe8a86ed7e"}}}}, {"uuid": "4574b2d1-fc8e-49ff-a25a-fc07d36b301d", "name": "e63794ba-c4ae-44ae-b439-bd3343a501d5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.056520022279634, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8635401886215074, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "756fa955-9680-480f-85b2-d5b52b29f99e", "name": "083c63fe-380e-41f3-9ba3-62772e37b557", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4574b2d1-fc8e-49ff-a25a-fc07d36b301d"}}}]}, {"uuid": "59c6d232-98a9-47e1-bed2-5e872041a8d2", "name": "load_p1rlv11392_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e740a352-ac8f-4ae2-ace3-254fccd7f96f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "756fa955-9680-480f-85b2-d5b52b29f99e"}}}}, {"uuid": "462390c9-21da-4beb-9fc6-0f0467cb6409", "name": "d7557778-2990-4193-bcab-760f907a022b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6676306342135938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5123446143614628, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a15ae177-76ec-43f0-a0c2-a1026e8ec787", "name": "dae2d185-f280-4645-9d77-2ef82f12b93c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "462390c9-21da-4beb-9fc6-0f0467cb6409"}}}]}, {"uuid": "278597eb-7589-4179-9c56-8147c045a63a", "name": "load_p1rlv11394_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "996d3e44-142c-42fa-bf4f-2bd1777122dd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a15ae177-76ec-43f0-a0c2-a1026e8ec787"}}}}, {"uuid": "3b3c4397-6414-48a5-990a-6ad45810e2a0", "name": "78e01f6b-d1e6-4496-bbec-41c47850519e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6676306342135938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5123446143614628, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ddd93c03-41d9-4a3c-81c1-1ba375c6c355", "name": "e342d2f3-4b04-4da0-9630-4b32275eb7c6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3b3c4397-6414-48a5-990a-6ad45810e2a0"}}}]}, {"uuid": "ab65142c-9c13-4a8c-8cc7-b104c63b5259", "name": "load_p1rlv11394_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "996d3e44-142c-42fa-bf4f-2bd1777122dd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ddd93c03-41d9-4a3c-81c1-1ba375c6c355"}}}}, {"uuid": "06de4b0e-2909-42a2-959d-aa5a6a240436", "name": "db623204-32c1-44e5-adc3-3c160b103c96_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0716401691896973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6949594139700135, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cb377bff-e6f7-4447-8797-48e32b35cd1a", "name": "0379a339-a2ec-462f-bf7e-b2e2e2a3cc96", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "06de4b0e-2909-42a2-959d-aa5a6a240436"}}}]}, {"uuid": "1e04e619-d127-4ea3-87ed-5eb9556ac87d", "name": "load_p1rlv11395_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29922f55-f36a-4b9e-8836-5f9dadd641b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cb377bff-e6f7-4447-8797-48e32b35cd1a"}}}}, {"uuid": "58db2d51-9c85-4843-83a6-cf19e369b34f", "name": "1c0b8270-742b-4189-8212-bf9144bc65af_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0716401691896973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6949594139700135, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "35c29600-c66e-4dc1-92ab-5574ce2dfe4e", "name": "cad04e0d-401c-4383-901c-67f3f7902974", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58db2d51-9c85-4843-83a6-cf19e369b34f"}}}]}, {"uuid": "908db140-2d30-4690-96be-fe82a41c7d68", "name": "load_p1rlv11395_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29922f55-f36a-4b9e-8836-5f9dadd641b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "35c29600-c66e-4dc1-92ab-5574ce2dfe4e"}}}}, {"uuid": "d5614689-653e-472f-9267-639e0d79a5f1", "name": "fa235b5c-542f-425f-8e7d-585216fa16af_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.8145950466373417, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09093602970127403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "736b85df-cb4e-4e9b-83cf-08ae8f791c33", "name": "9d31ebe3-0876-4f4a-962e-66d5f02222c8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d5614689-653e-472f-9267-639e0d79a5f1"}}}]}, {"uuid": "eb1321da-6da4-4467-b70d-211ce256bd9d", "name": "load_p1rlv11397_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fd316b0-fd98-4193-9c1b-aaa7d92a4284"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "736b85df-cb4e-4e9b-83cf-08ae8f791c33"}}}}, {"uuid": "c9ca1464-7f8d-4a34-9c17-7bcd4af77466", "name": "32f1b799-0314-4cee-9183-a6e1d85e616a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.8145950466373417, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09093602970127403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7ec03626-15d0-482f-8e2c-732f4fa3238e", "name": "de74e497-95d5-40ed-bb4b-e8d05267a90c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9ca1464-7f8d-4a34-9c17-7bcd4af77466"}}}]}, {"uuid": "716a39f1-ba9a-4a83-b6b0-1e8b432d48ac", "name": "load_p1rlv11397_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fd316b0-fd98-4193-9c1b-aaa7d92a4284"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7ec03626-15d0-482f-8e2c-732f4fa3238e"}}}}, {"uuid": "c88b7522-4bd8-49d0-bc8e-b13cc33d39ac", "name": "ac5c5c8d-2059-4ae0-a96e-2e4ef1fc7da5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 23.859207702115498, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3391872562704328, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d557504b-7f7f-4144-bab4-599b9a9b4147", "name": "b361a8d0-1846-477b-ad03-cdb801178674", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c88b7522-4bd8-49d0-bc8e-b13cc33d39ac"}}}]}, {"uuid": "1227d484-abf8-457b-9a16-2712f4293348", "name": "load_p1rlv11398_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97aa01fe-2e60-4617-8c89-d36f425087fe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d557504b-7f7f-4144-bab4-599b9a9b4147"}}}}, {"uuid": "5095d65a-f8f9-43ad-9509-bd1a682fb4de", "name": "1fdd615c-4a8b-45df-a664-b7afad3317cc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 23.859207702115498, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3391872562704328, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1100417b-7762-42c1-84e3-9df8982977b1", "name": "67c88a92-b4bf-420a-842a-9d6c7bf6ff8b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5095d65a-f8f9-43ad-9509-bd1a682fb4de"}}}]}, {"uuid": "ab6196e1-93f6-4f4a-ba8f-dfceaed4b375", "name": "load_p1rlv11398_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97aa01fe-2e60-4617-8c89-d36f425087fe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1100417b-7762-42c1-84e3-9df8982977b1"}}}}, {"uuid": "c85d0dcd-b204-4eab-b636-4bd71b02ac73", "name": "a34faa76-5042-44d6-a7c0-7fa364a76449_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.936474762797392, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1018059929469786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "93ed52e0-29fd-47f1-bcff-9e635f2710c4", "name": "fe1551b2-4899-4058-ba17-33095af84ca7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c85d0dcd-b204-4eab-b636-4bd71b02ac73"}}}]}, {"uuid": "0dd259e1-6337-42d8-8b1a-f1167ba06871", "name": "load_p1rlv11399_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68a9eead-8197-4e82-a444-2a4544ec9ddb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "93ed52e0-29fd-47f1-bcff-9e635f2710c4"}}}}, {"uuid": "475d83d0-97e4-4073-9eb4-c4054a6a73c6", "name": "58181977-2e65-49af-bac7-75f122b75525_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.936474762797392, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1018059929469786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "412f3c1c-8bd1-4f9a-8b78-ff10d0dc33af", "name": "442532b1-69f9-4bd4-be04-fd2195a09331", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "475d83d0-97e4-4073-9eb4-c4054a6a73c6"}}}]}, {"uuid": "14f5c982-a941-47eb-bbe3-5a71b7002ef0", "name": "load_p1rlv11399_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68a9eead-8197-4e82-a444-2a4544ec9ddb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "412f3c1c-8bd1-4f9a-8b78-ff10d0dc33af"}}}}, {"uuid": "1c93c64e-c366-4e8e-be51-80ed7c2dc1ab", "name": "a8d1b8f8-964b-4152-88cf-546f652122a5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7362273540893955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24527287728713068, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1f94519d-76c3-44f3-a4aa-a413daa3fc09", "name": "e9273d34-b533-405f-ab46-06cf3d1cbebd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1c93c64e-c366-4e8e-be51-80ed7c2dc1ab"}}}]}, {"uuid": "1a8b6d99-326a-4863-aafb-24b633c2de28", "name": "load_p1rlv11401_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a215d7dd-8081-4355-9c38-4fd3d2c859c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1f94519d-76c3-44f3-a4aa-a413daa3fc09"}}}}, {"uuid": "ed3a85b5-cc99-4309-803f-597146e69b7e", "name": "c2716fdb-6260-4b4e-99ee-3110b4c6e13b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7362273540893955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24527287728713068, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e6c2ba32-641e-40be-9196-97d7f0cdc413", "name": "e8b64d33-8988-4766-ac6b-b5cf996fed76", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ed3a85b5-cc99-4309-803f-597146e69b7e"}}}]}, {"uuid": "d2095444-e584-4f9e-96d6-7ee82d3f56cf", "name": "load_p1rlv11401_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a215d7dd-8081-4355-9c38-4fd3d2c859c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e6c2ba32-641e-40be-9196-97d7f0cdc413"}}}}, {"uuid": "19e6f0e2-d912-4218-9fd1-fd4d0924d194", "name": "217e84b9-c92a-4813-bda6-016f6ec450d4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.993849790823018, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8230403105677124, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "81000f39-1c4b-48e4-b9af-0b7e8a375a30", "name": "3e931a47-39f4-49a1-b7c1-d1a5dca4f47a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "19e6f0e2-d912-4218-9fd1-fd4d0924d194"}}}]}, {"uuid": "880c8a8f-8311-4eea-85c3-081629e5d51a", "name": "load_p1rlv11671_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "834a5733-5264-4adf-861a-25e494df3e37"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "81000f39-1c4b-48e4-b9af-0b7e8a375a30"}}}}, {"uuid": "fa41be16-4f77-4d8b-8d3c-5bded2c2b3d2", "name": "3a0c9a3d-d0d9-4cef-b356-9296bc4e6ebb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.993849790823018, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8230403105677124, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5de76861-367c-419e-9ebf-d23598dc70c8", "name": "c79e609b-1aa4-4707-894b-5b353a30e4b3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fa41be16-4f77-4d8b-8d3c-5bded2c2b3d2"}}}]}, {"uuid": "ffffb06b-53dd-40e2-88d0-c56f9b9119a7", "name": "load_p1rlv11671_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "834a5733-5264-4adf-861a-25e494df3e37"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5de76861-367c-419e-9ebf-d23598dc70c8"}}}}, {"uuid": "7b0aea3d-5a84-4c93-8187-72c99666a6e7", "name": "9ef80507-36c4-4ed5-a827-d4bab96aa770_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.207629741893862, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.47552489685620736, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cdaab1e9-9218-4f89-879c-17def2df400d", "name": "b090e00b-d7e5-485d-998b-bb3e5a4156b2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b0aea3d-5a84-4c93-8187-72c99666a6e7"}}}]}, {"uuid": "4280bfa9-be32-40fd-bdb0-2e913cfe06f7", "name": "load_p1rlv11674_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "45f2a901-e4f7-4055-a3e2-b60c61d5033e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cdaab1e9-9218-4f89-879c-17def2df400d"}}}}, {"uuid": "942399c1-c215-463d-ab01-2b5b49c33988", "name": "2ada6355-9751-4aa1-8e94-23629ffcbcea_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.207629741893862, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.47552489685620736, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "88679627-5a13-4b2f-9104-c1ab907ef8d2", "name": "7dc64782-55da-4ebf-9774-248dfaf2aeb3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "942399c1-c215-463d-ab01-2b5b49c33988"}}}]}, {"uuid": "3afad982-a47a-4bfd-b962-d5030608149a", "name": "load_p1rlv11674_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "45f2a901-e4f7-4055-a3e2-b60c61d5033e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "88679627-5a13-4b2f-9104-c1ab907ef8d2"}}}}, {"uuid": "7fdeae6b-bad2-4d38-a3eb-b1b886bb88b2", "name": "58c28d80-812f-4f45-b252-f3b925518e56_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.350180554065672, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.234423023465851, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "78047efa-5aae-4c22-bbfd-1e309fce9b3d", "name": "5014b4f3-eb2f-4d8a-b195-fedddd1a282a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7fdeae6b-bad2-4d38-a3eb-b1b886bb88b2"}}}]}, {"uuid": "e21bce72-76a7-41e5-bfdb-2fd16a75d549", "name": "load_p1rlv11677_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b2f121a-2202-43c0-8684-81913a5d6ea9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "78047efa-5aae-4c22-bbfd-1e309fce9b3d"}}}}, {"uuid": "3fb2b49c-5421-416a-81b8-ed45941c710b", "name": "010a5d40-5063-4cec-b10e-a8c6e97802f0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.350180554065672, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.234423023465851, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cbba316b-4388-493d-bebf-b65b224f77b1", "name": "9dc512e3-833a-4d0a-901e-d9d6f764a902", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3fb2b49c-5421-416a-81b8-ed45941c710b"}}}]}, {"uuid": "82bec9a8-854a-4931-b6be-6add2702d1a6", "name": "load_p1rlv11677_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b2f121a-2202-43c0-8684-81913a5d6ea9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cbba316b-4388-493d-bebf-b65b224f77b1"}}}}, {"uuid": "73a7b9d9-ecd8-46e9-8986-42f2efd7f8c6", "name": "84a7323c-c0fb-4d34-8f47-c23cb918fafe_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.646242553828346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.7481060562472628, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2a45bee3-8c33-4cbe-a582-6377ecc23b9f", "name": "84a7323c-c0fb-4d34-8f47-c23cb918fafe_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.646242553828346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.7481060562472628, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7b0b3590-6acf-417b-9bb2-452f23225443", "name": "84a7323c-c0fb-4d34-8f47-c23cb918fafe_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.646242553828346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.7481060562472628, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f34e4e1c-6c8f-4059-adc9-2b64ec93e326", "name": "f086a3d6-c467-4700-abc5-5d2277d44341", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "73a7b9d9-ecd8-46e9-8986-42f2efd7f8c6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2a45bee3-8c33-4cbe-a582-6377ecc23b9f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b0b3590-6acf-417b-9bb2-452f23225443"}}}]}, {"uuid": "199bfa85-465c-4650-8ef3-90f96b88b204", "name": "load_p1rlv11679", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4747e0f3-2a66-4e5a-8160-ac0aabe34489"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f34e4e1c-6c8f-4059-adc9-2b64ec93e326"}}}}, {"uuid": "0e0463d4-ce3e-4fc6-9932-5ad1716ba8a4", "name": "065c9709-49a5-4a99-969e-d1ab3384fb45_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5348201699646123, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21241824123648728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f04a5ba1-dccd-43ea-9d4c-422a4ef9bc8f", "name": "a950f1cc-c8ce-471b-b119-37def2974705", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0e0463d4-ce3e-4fc6-9932-5ad1716ba8a4"}}}]}, {"uuid": "eeae5cd3-47cb-420f-82eb-e82981fc3166", "name": "load_p1rlv11684_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02aef971-5f4a-4ca8-aa33-cce34517bd44"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f04a5ba1-dccd-43ea-9d4c-422a4ef9bc8f"}}}}, {"uuid": "c113a2d0-7a1a-4ef0-b68c-e48e85a1090f", "name": "54701ebb-2c42-4b9d-9413-2113bdd4b2d5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5348201699646123, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21241824123648728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "146aded8-811d-43e7-93c3-2ff6315ddb15", "name": "4fdd7731-7414-4d6a-b123-66bb72d3735f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c113a2d0-7a1a-4ef0-b68c-e48e85a1090f"}}}]}, {"uuid": "39427790-3cc9-4d35-b072-1b8584b28d52", "name": "load_p1rlv11684_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02aef971-5f4a-4ca8-aa33-cce34517bd44"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "146aded8-811d-43e7-93c3-2ff6315ddb15"}}}}, {"uuid": "0f0f3eff-f75b-412b-b376-fd15c18d9230", "name": "711648f9-ebb7-4f4e-b932-f24da15200e6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7134847388598258, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.27646838411203456, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2074fde9-c64d-43a4-9028-6b9f09dd0c72", "name": "910b07e4-fe64-4347-a582-ae11ab6afa54", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0f0f3eff-f75b-412b-b376-fd15c18d9230"}}}]}, {"uuid": "f74274b2-e40e-49ec-a06e-9124509405b4", "name": "load_p1rlv11686_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cda8e361-98b6-49bd-a3ff-30a036a3dc6f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2074fde9-c64d-43a4-9028-6b9f09dd0c72"}}}}, {"uuid": "5b421636-ffa4-4703-9f40-c5fa17a9ef1a", "name": "0009cc4f-de5f-4ad5-aa48-0ff3c85e7cb0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7134847388598258, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.27646838411203456, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a935d79-007f-4e78-9f82-58519fc58985", "name": "64531b1b-d21e-47e0-90b2-87975e64e9bc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b421636-ffa4-4703-9f40-c5fa17a9ef1a"}}}]}, {"uuid": "0128e4c0-7225-4072-81cb-76e07c494424", "name": "load_p1rlv11686_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cda8e361-98b6-49bd-a3ff-30a036a3dc6f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a935d79-007f-4e78-9f82-58519fc58985"}}}}, {"uuid": "bcaa9aa5-7611-4cab-8e97-f648f007f6ec", "name": "8ac0ffc9-1f1f-4e44-b05b-3c6c4e9f4bcf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.685213211371405, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7584354740780123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b6106aee-0e71-4823-9b54-b821dbe6e9e3", "name": "2518ab62-028f-406d-8805-cd8ff9e7c663", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bcaa9aa5-7611-4cab-8e97-f648f007f6ec"}}}]}, {"uuid": "2f03a659-6950-4b38-824c-fcab53770ada", "name": "load_p1rlv11779_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0ba1408-17da-4678-8b04-90c616c3fb48"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b6106aee-0e71-4823-9b54-b821dbe6e9e3"}}}}, {"uuid": "54d15814-1f86-46d8-ba4e-8005594b9e8c", "name": "673f5872-4f13-461c-8547-73d1563f4ca2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.685213211371405, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7584354740780123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "68e84740-bc6d-46b3-b5a1-de230ba2ba8c", "name": "d8fcf121-24ec-4589-af9b-16f85e167894", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "54d15814-1f86-46d8-ba4e-8005594b9e8c"}}}]}, {"uuid": "36b3f0e7-e125-444a-953f-0f418ce90d34", "name": "load_p1rlv11779_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0ba1408-17da-4678-8b04-90c616c3fb48"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "68e84740-bc6d-46b3-b5a1-de230ba2ba8c"}}}}, {"uuid": "2bc5ddc5-f9cf-4c31-a698-e45162a59f52", "name": "de86f7c4-960b-434d-a501-6e2a48c45b5e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8140781365796688, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5845737413475921, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f8b6903-d695-4864-8bd1-5d6ef43823d3", "name": "9f5d99d3-8bbb-4f4b-82b3-c6fa3a499604", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2bc5ddc5-f9cf-4c31-a698-e45162a59f52"}}}]}, {"uuid": "ae28e7f9-10c4-4478-beb9-3cda7def6e12", "name": "load_p1rlv11780_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e9a574d-9537-417a-a811-e22d84b8ea53"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f8b6903-d695-4864-8bd1-5d6ef43823d3"}}}}, {"uuid": "0bb832a9-296f-4ab9-b79f-c6729e9a95f1", "name": "b62bc94e-46b0-4893-b9d9-63b0d76a65c4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8140781365796688, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5845737413475921, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d6007af3-04d8-4d6b-98a0-75e82c07ad9e", "name": "aa693dc2-7f08-4d51-bd8d-957884a3cb4b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0bb832a9-296f-4ab9-b79f-c6729e9a95f1"}}}]}, {"uuid": "2b081bb3-2ae6-44e9-bff1-82782c105da7", "name": "load_p1rlv11780_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e9a574d-9537-417a-a811-e22d84b8ea53"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d6007af3-04d8-4d6b-98a0-75e82c07ad9e"}}}}, {"uuid": "384cf2bf-2e3f-496f-8c9f-7c60d688c039", "name": "8a16d511-aa5c-4d7e-8a2a-dc06a8786cf8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.511185229285174, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8722130080127372, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6a3dec04-d7d9-4d23-9487-257b4c3812db", "name": "49c94614-c682-4183-a3ee-47532aeabbd9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "384cf2bf-2e3f-496f-8c9f-7c60d688c039"}}}]}, {"uuid": "d9cfe7dd-04e6-4dcf-ab7f-2acbe28a3430", "name": "load_p1rlv11781_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28fd9f7c-0195-4529-a972-aa60eced47d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6a3dec04-d7d9-4d23-9487-257b4c3812db"}}}}, {"uuid": "d02a4dfd-0db0-4c84-a0d0-55acac4da244", "name": "f894fb6a-1944-4860-81b8-0d511b69b152_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.511185229285174, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8722130080127372, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "04f35fd9-0ef5-4f14-a6e3-cefc0476f467", "name": "65a6d6bc-d2e4-4d3c-87c0-3c49631c0586", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d02a4dfd-0db0-4c84-a0d0-55acac4da244"}}}]}, {"uuid": "784301f3-c814-4f30-a094-a5ad526eafc4", "name": "load_p1rlv11781_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28fd9f7c-0195-4529-a972-aa60eced47d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "04f35fd9-0ef5-4f14-a6e3-cefc0476f467"}}}}, {"uuid": "c29d78d2-6f86-4a75-8639-46b5737b9f3a", "name": "da9297a7-e14d-4032-80c3-bd916fb0f82e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9571742049653674, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.37384849940856246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c91df66f-cf2c-4308-9e5e-6ae3c4236103", "name": "598bffc5-e44d-4424-b327-473c6b33c699", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c29d78d2-6f86-4a75-8639-46b5737b9f3a"}}}]}, {"uuid": "d4d57c2d-e4fb-45e4-8ca1-5861e1d03e26", "name": "load_p1rlv11782_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "496fc854-bbf8-463b-b16c-12dd1b444cc6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c91df66f-cf2c-4308-9e5e-6ae3c4236103"}}}}, {"uuid": "59ec2523-a40e-4626-83a9-942fb8b00d3c", "name": "0175315c-636a-4bdf-8ec1-9ece9762cfd7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9571742049653674, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.37384849940856246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "55fe2d83-23b8-4e04-bb5f-c0c39fa59d22", "name": "7ffab4d1-ae5f-47c4-bc80-1b5ef215933d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "59ec2523-a40e-4626-83a9-942fb8b00d3c"}}}]}, {"uuid": "dc1725f4-043c-489e-ad6e-a489b6a3ddde", "name": "load_p1rlv11782_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "496fc854-bbf8-463b-b16c-12dd1b444cc6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "55fe2d83-23b8-4e04-bb5f-c0c39fa59d22"}}}}, {"uuid": "719f3565-2a90-447f-b37f-62c4575685a5", "name": "74b0364c-70f7-4cfa-9a50-696d19276a50_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6943701970081404, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21264462112520055, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "04a97427-3eb0-4dd5-8318-2b1618f2db99", "name": "25c4c1f0-dda3-4377-ab72-f6328c96ad2c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "719f3565-2a90-447f-b37f-62c4575685a5"}}}]}, {"uuid": "c0d0846d-b13d-4842-be91-f5890fae2efa", "name": "load_p1rlv11783_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3890375-c01d-44d2-93f9-8d9d60da8852"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "04a97427-3eb0-4dd5-8318-2b1618f2db99"}}}}, {"uuid": "a833347b-51ca-4335-a3b7-2815a8802252", "name": "715e0283-8919-4ab8-8785-bd42398faa71_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6943701970081404, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21264462112520055, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d4366736-a6a8-4466-bdda-dd0d4f71e800", "name": "c972beca-c3aa-48b8-9bb8-2e95b0231cd1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a833347b-51ca-4335-a3b7-2815a8802252"}}}]}, {"uuid": "7a0211f4-3574-4963-8c61-ef4aa454aab7", "name": "load_p1rlv11783_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3890375-c01d-44d2-93f9-8d9d60da8852"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d4366736-a6a8-4466-bdda-dd0d4f71e800"}}}}, {"uuid": "74aeab76-c309-4409-b010-a63870f4cc44", "name": "2bb9988e-44b9-4e7a-a6e6-1457f5fd33ec_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.991741378519742, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22993168819558238, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "70c39461-4170-4085-8dd6-3521bdb1cee8", "name": "f6e7cbfd-d137-4329-92ee-5b9518fb7227", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "74aeab76-c309-4409-b010-a63870f4cc44"}}}]}, {"uuid": "bbaa94b7-26a0-4490-b73f-3f48efcd8109", "name": "load_p1rlv11784_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b66df0bc-6159-42fa-bf49-b8ad17d0e6aa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "70c39461-4170-4085-8dd6-3521bdb1cee8"}}}}, {"uuid": "14682214-bd52-4703-aeee-3855f6362b25", "name": "b01eff19-3110-434c-8ce9-8d5f9e392f71_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.991741378519742, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22993168819558238, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4c696357-ac6d-45a4-962b-355e9c7383a4", "name": "419de2c8-9215-4618-8fc3-0beef31859c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "14682214-bd52-4703-aeee-3855f6362b25"}}}]}, {"uuid": "f229a1db-0bdf-43d2-865e-4cddd2b3dd8c", "name": "load_p1rlv11784_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b66df0bc-6159-42fa-bf49-b8ad17d0e6aa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4c696357-ac6d-45a4-962b-355e9c7383a4"}}}}, {"uuid": "81aa2444-620f-45cc-98de-960fa593c2a6", "name": "5f30cec8-7b02-4fd1-b591-a2178d76d175_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9304883858291884, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.26579705258029934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5b8b6400-52cf-4605-af6d-5c3539407e22", "name": "892222e6-9006-4e8c-b1aa-6f9b3a88f2ca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "81aa2444-620f-45cc-98de-960fa593c2a6"}}}]}, {"uuid": "67f8b117-f8aa-4709-9095-1e625b55aaea", "name": "load_p1rlv11785_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ed0eb774-fcc3-417f-a8a4-fbdb825cc106"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5b8b6400-52cf-4605-af6d-5c3539407e22"}}}}, {"uuid": "1a8a6352-2858-476d-b4ae-541f4571c5d7", "name": "7cc3f58f-d2dc-4bee-9e76-d93a317bd5c2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9304883858291884, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.26579705258029934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "96c26c44-bee9-4f3d-8e1d-05ca261685b3", "name": "3fa9c194-4aa5-456e-a3bb-6475f8f83efb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1a8a6352-2858-476d-b4ae-541f4571c5d7"}}}]}, {"uuid": "7097c4ee-e786-4b71-b2a3-dd97cf49206a", "name": "load_p1rlv11785_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ed0eb774-fcc3-417f-a8a4-fbdb825cc106"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "96c26c44-bee9-4f3d-8e1d-05ca261685b3"}}}}, {"uuid": "b645010e-a80c-4a8e-847c-83155db97703", "name": "48b0ad64-80f4-4225-8b12-69d1c1fce2b4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9049571169929809, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.186253723079565, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "634e1d2e-df5c-4213-ab8a-387c3beb319a", "name": "43db1fb5-a161-48cd-b379-8efe6752dab5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b645010e-a80c-4a8e-847c-83155db97703"}}}]}, {"uuid": "70aaccc7-152f-4181-a716-cb618ede64a9", "name": "load_p1rlv11786_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b15fc66-89d9-483b-9c9f-9b0f39a63b29"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "634e1d2e-df5c-4213-ab8a-387c3beb319a"}}}}, {"uuid": "a27cf930-a2b9-45cb-833a-29d62bb98417", "name": "843c52bb-2b47-41ee-b817-12e7df53e0e9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9049571169929809, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.186253723079565, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4d47c6dc-872d-406b-a442-3bc658bf26b7", "name": "d430dd13-01cb-4cda-9824-6fb09a44693f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a27cf930-a2b9-45cb-833a-29d62bb98417"}}}]}, {"uuid": "257419d1-b753-4d96-bdce-38e1a1cd8134", "name": "load_p1rlv11786_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b15fc66-89d9-483b-9c9f-9b0f39a63b29"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4d47c6dc-872d-406b-a442-3bc658bf26b7"}}}}, {"uuid": "b05a753d-3db7-48b3-b47a-249c98ff3be1", "name": "a4b00cd0-fd5a-4f22-9a52-ed3053b4ee85_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.074192704000552, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.129078804753558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c988968-65a0-4532-a19d-556a07293824", "name": "44cf0c3d-0316-4a19-8733-0a867704b781", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b05a753d-3db7-48b3-b47a-249c98ff3be1"}}}]}, {"uuid": "e253f6fb-990c-4d8b-8948-9a3229cac708", "name": "load_p1rlv12028_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1dfd848-b639-41b5-ad95-2c03a51bd36b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c988968-65a0-4532-a19d-556a07293824"}}}}, {"uuid": "203f3b4c-a1b7-4d7d-8dde-44bba643968d", "name": "a49857dd-c662-47fa-b3d3-1bc2676ae6c5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.074192704000552, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.129078804753558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "07a841f3-9e9e-435e-8921-90257903027f", "name": "5e806831-a196-41a9-9872-c316842d0c89", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "203f3b4c-a1b7-4d7d-8dde-44bba643968d"}}}]}, {"uuid": "f55cbd96-3d00-4c50-9b1e-7949b1ccf7fa", "name": "load_p1rlv12028_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1dfd848-b639-41b5-ad95-2c03a51bd36b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "07a841f3-9e9e-435e-8921-90257903027f"}}}}, {"uuid": "552e95b7-8899-4680-b787-bd09d88fcbad", "name": "d624f5a9-8df5-49d9-8aab-f0ab2829963b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9920550244580673, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.016709072862991, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4a17a3d5-f916-40a8-9a3c-a75fabf7c4b9", "name": "04652eab-da1b-44bb-b119-da71f87b7c49", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "552e95b7-8899-4680-b787-bd09d88fcbad"}}}]}, {"uuid": "15f6d0d3-47f6-405d-860f-4c1f270e1b38", "name": "load_p1rlv12157_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc4d79bb-8ba3-4146-9d50-16db48ffec22"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4a17a3d5-f916-40a8-9a3c-a75fabf7c4b9"}}}}, {"uuid": "616909e4-20b5-4c69-8ff7-6e76d1373619", "name": "9a778301-544c-4279-8090-78f38718cff6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9920550244580673, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.016709072862991, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a0eda67-fcf7-4f79-9913-20f1f19267d3", "name": "3797bb29-31a1-4c97-b879-c67117445909", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "616909e4-20b5-4c69-8ff7-6e76d1373619"}}}]}, {"uuid": "7cf4078b-8cea-45d9-b31f-65e4f30ac480", "name": "load_p1rlv12157_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc4d79bb-8ba3-4146-9d50-16db48ffec22"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0a0eda67-fcf7-4f79-9913-20f1f19267d3"}}}}, {"uuid": "93349afb-bb23-4e5a-96c4-865535c7fce2", "name": "387701da-b42d-4acc-9a36-d349f1506115_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4651344294517608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7736313908316925, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bbe48d7c-1401-44fa-9c7f-809f2a444159", "name": "a44c1150-9305-4d3e-b8c4-f08012ed1336", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "93349afb-bb23-4e5a-96c4-865535c7fce2"}}}]}, {"uuid": "90927d12-f7db-4258-9750-300ae537663f", "name": "load_p1rlv12214_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df9d9de2-6929-48a4-a390-c0e2f129b374"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bbe48d7c-1401-44fa-9c7f-809f2a444159"}}}}, {"uuid": "940f19a6-726f-4ae7-ab9c-62ed4a687ede", "name": "c22de480-94ab-4386-8777-6352bb23c4a9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4651344294517608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7736313908316925, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a359518f-9c6f-44f3-bba7-02c74e67773b", "name": "7cafa9c5-8e2b-4908-8492-7901adf43b91", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "940f19a6-726f-4ae7-ab9c-62ed4a687ede"}}}]}, {"uuid": "be825c77-6ca2-4d5d-99a4-53a5543c2ea2", "name": "load_p1rlv12214_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df9d9de2-6929-48a4-a390-c0e2f129b374"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a359518f-9c6f-44f3-bba7-02c74e67773b"}}}}, {"uuid": "8000ba09-9e9b-47e7-9248-e5cd7eb89b1f", "name": "9390d150-0a92-45a1-a68b-a305c8617dcd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.84153235443771, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.447226409705929, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7c1a452d-e2b6-417d-a4f3-f8b3e9b59441", "name": "413ffaf3-a662-40e4-a1cb-4187df3cca66", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8000ba09-9e9b-47e7-9248-e5cd7eb89b1f"}}}]}, {"uuid": "a5fee8da-8631-4a13-a56e-4b3ac2d97499", "name": "load_p1rlv12217_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4d26673-c304-41de-8b5b-149552601ba4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7c1a452d-e2b6-417d-a4f3-f8b3e9b59441"}}}}, {"uuid": "c90df63f-8a49-4713-98f6-06f17ab46792", "name": "ea12689a-7116-40d9-a027-ca1635ed75dc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.84153235443771, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.447226409705929, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0e05b6fc-4c45-4fd7-9c22-8340c45a3606", "name": "8b56535d-9f54-4ad3-9c6a-791882e318e3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c90df63f-8a49-4713-98f6-06f17ab46792"}}}]}, {"uuid": "e485265f-9f8d-4245-ad17-5d4e5e1c3807", "name": "load_p1rlv12217_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4d26673-c304-41de-8b5b-149552601ba4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0e05b6fc-4c45-4fd7-9c22-8340c45a3606"}}}}, {"uuid": "eb75ab7d-98c0-4140-aef1-328cd7e4116d", "name": "0760525e-b253-41d0-b2cd-687cd73d9c1e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.799969889792979, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7055837837850989, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "042dfb11-6154-4b13-9408-0cd2ab142536", "name": "ab587f0c-6725-497c-ad32-aa49117ef7a8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eb75ab7d-98c0-4140-aef1-328cd7e4116d"}}}]}, {"uuid": "bc041c92-4b53-4a56-a2fb-e457b789cd43", "name": "load_p1rlv12222_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cee79fe8-f140-4be9-aa6b-d56e37fb6857"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "042dfb11-6154-4b13-9408-0cd2ab142536"}}}}, {"uuid": "b0d438e5-c608-402c-b4f6-9f25bd01a42e", "name": "c6b2d280-584e-43d4-a753-6be9b18ab723_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.799969889792979, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7055837837850989, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e7a368d6-2f67-4798-acb9-d269a780643e", "name": "d8f0ae6e-e5fc-404e-94db-798335a77be1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b0d438e5-c608-402c-b4f6-9f25bd01a42e"}}}]}, {"uuid": "79f820d2-8c76-454c-8b6f-c034813dfa94", "name": "load_p1rlv12222_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cee79fe8-f140-4be9-aa6b-d56e37fb6857"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e7a368d6-2f67-4798-acb9-d269a780643e"}}}}, {"uuid": "8a292298-d87c-40ba-99b3-0870bd235430", "name": "4aff0686-b279-4769-8696-0f117f3f32ab_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0087998942532215, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8303357169547151, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7a23e6bd-80a6-48f6-9573-655b5666a234", "name": "4fab9f05-0766-47da-9a87-043511271416", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a292298-d87c-40ba-99b3-0870bd235430"}}}]}, {"uuid": "1711e0a2-ee71-472d-9af5-5fa31beeaac0", "name": "load_p1rlv12225_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8e1f797-9417-447c-8a08-cf00a462ef14"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7a23e6bd-80a6-48f6-9573-655b5666a234"}}}}, {"uuid": "4f1b5334-965c-4525-a322-5fe06c498bb7", "name": "ea7d87bf-96a1-4601-b23b-bda186f96246_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0087998942532215, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8303357169547151, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bdaf1aa2-43b3-47cd-9d94-8e7d2bb7b510", "name": "398b200b-5935-44e0-ab49-e5e703cf9715", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4f1b5334-965c-4525-a322-5fe06c498bb7"}}}]}, {"uuid": "4b1b40e1-5681-448e-a18b-39482f3ba885", "name": "load_p1rlv12225_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8e1f797-9417-447c-8a08-cf00a462ef14"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bdaf1aa2-43b3-47cd-9d94-8e7d2bb7b510"}}}}, {"uuid": "b8deb33a-f898-4d69-97ce-bf091c2f724e", "name": "384f4eb4-eab8-4690-886d-9cf71c4744d7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "55635006-f0f4-4f03-80e7-0beecf5255f6", "name": "6d2bbb29-4ca4-4dd4-8fef-eb4cb60eb63e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b8deb33a-f898-4d69-97ce-bf091c2f724e"}}}]}, {"uuid": "d0db2faa-7719-4473-9f95-ecdc785a82de", "name": "load_p1rlv12538_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b42c2471-9114-4042-980e-dd226ad024a3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "55635006-f0f4-4f03-80e7-0beecf5255f6"}}}}, {"uuid": "38ca2981-1679-4764-a838-f05b5da5b7b2", "name": "e4d803a9-4542-4d57-88bc-b050a947ef29_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b0938b16-1cb9-4e1a-8d43-6ef059d68218", "name": "5ecac895-5d8e-4356-a367-3fc11dfe5b1a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "38ca2981-1679-4764-a838-f05b5da5b7b2"}}}]}, {"uuid": "4bdaf9b4-ca85-4214-b3d0-fab6ecc04fa0", "name": "load_p1rlv12538_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b42c2471-9114-4042-980e-dd226ad024a3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b0938b16-1cb9-4e1a-8d43-6ef059d68218"}}}}, {"uuid": "7af170d2-f91e-49a1-b46a-9d1b3fdac5c2", "name": "fbc4c379-57b8-4715-be21-42a6b2e361f4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.019297318507635, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.02246974709606756, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1fac8763-3ee1-43e7-bcf3-41617c46e963", "name": "f8e332fc-ec82-416e-b3d6-8b14e1a23653", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7af170d2-f91e-49a1-b46a-9d1b3fdac5c2"}}}]}, {"uuid": "28b67365-ae57-4a50-9c3f-0d620c71a219", "name": "load_p1rlv12552_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c42d772-e2a8-45d4-9cf2-2edd7a567b35"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1fac8763-3ee1-43e7-bcf3-41617c46e963"}}}}, {"uuid": "a378f8a4-8021-485f-860d-aa2a2032d46d", "name": "c6a7766f-684b-4d18-8619-a3e8a6fb87ce_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.019297318507635, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.02246974709606756, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f2ffd1ed-8ac4-4d30-bf95-beddb8475dfb", "name": "87f2a343-b853-4cce-827f-1d2dbc76cb67", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a378f8a4-8021-485f-860d-aa2a2032d46d"}}}]}, {"uuid": "9667ccde-7679-492a-80de-2ab510342e72", "name": "load_p1rlv12552_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c42d772-e2a8-45d4-9cf2-2edd7a567b35"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f2ffd1ed-8ac4-4d30-bf95-beddb8475dfb"}}}}, {"uuid": "31838ae9-5bec-4bfe-83d3-5a758bb306f4", "name": "8d2dfc6e-c33b-4d6c-be06-4b5f020bb41a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2219087879829873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3595087789107823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "13e11be6-6fef-46bd-a8ff-df8d3810df63", "name": "7e84ed5f-2b1e-4383-92e9-5ec8f0524021", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "31838ae9-5bec-4bfe-83d3-5a758bb306f4"}}}]}, {"uuid": "5dda57ed-b319-494c-9d87-380540189d12", "name": "load_p1rlv12553_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a29aec49-62a4-41ec-a67c-a84470a23f7b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "13e11be6-6fef-46bd-a8ff-df8d3810df63"}}}}, {"uuid": "10f2e55a-4148-43f9-a8e9-4720e944f9db", "name": "f9bc0bd6-0fa0-4d6b-aa84-287b48754b10_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2219087879829873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3595087789107823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1efcf0f6-12e0-457b-994d-41864b64821c", "name": "f4aef277-ad74-480c-8e1d-45906fd74985", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "10f2e55a-4148-43f9-a8e9-4720e944f9db"}}}]}, {"uuid": "7ce39498-91c4-4f3a-bdee-ca51755f3d8f", "name": "load_p1rlv12553_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a29aec49-62a4-41ec-a67c-a84470a23f7b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1efcf0f6-12e0-457b-994d-41864b64821c"}}}}, {"uuid": "e17e5f3b-1fa7-4e02-83f1-70a065023638", "name": "0500e3cd-6e22-4a48-bd68-2da9bc824009_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "77c2f716-98c7-4441-bb4a-bb0c0f6784c8", "name": "0500e3cd-6e22-4a48-bd68-2da9bc824009_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bf053ec5-8ce2-4779-9c8a-07b6844e1fbc", "name": "0500e3cd-6e22-4a48-bd68-2da9bc824009_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c5a6b4d5-ace0-436b-827a-428dd72a82ca", "name": "a105b17e-37ea-4df0-8c38-0552a55db7ce", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e17e5f3b-1fa7-4e02-83f1-70a065023638"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "77c2f716-98c7-4441-bb4a-bb0c0f6784c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bf053ec5-8ce2-4779-9c8a-07b6844e1fbc"}}}]}, {"uuid": "c6d2bf5b-f470-40ce-b8e4-96cfd0e92a44", "name": "load_p1rlv12555", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc71e486-4a44-466d-bc57-85591b269949"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c5a6b4d5-ace0-436b-827a-428dd72a82ca"}}}}, {"uuid": "1cbd663f-6a1c-4ea8-bded-0d70d902cae6", "name": "f1be257d-cb3a-4fc0-8586-41749bc934a6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.885552109924766, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6041260127278384, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ffec3052-3abb-4450-8007-84eb1a135bdd", "name": "4dc44239-3a7f-4899-a30b-0117e115c1b5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1cbd663f-6a1c-4ea8-bded-0d70d902cae6"}}}]}, {"uuid": "7db8574c-df37-49fc-8c22-8dbf718a039b", "name": "load_p1rlv12557_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fe4d6ae-cca5-476c-981a-a1dcd27b1e84"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ffec3052-3abb-4450-8007-84eb1a135bdd"}}}}, {"uuid": "b0bf587d-8b6c-44a5-a550-676ae3aeb192", "name": "f4b5e26d-8b61-4ee2-8ecf-038f2fb4bca0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.885552109924766, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6041260127278384, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e6120965-3163-44d8-8795-e883b0e34afe", "name": "d3b636f0-790f-4e54-9421-c06065a70246", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b0bf587d-8b6c-44a5-a550-676ae3aeb192"}}}]}, {"uuid": "2ce60fb7-a0a5-4497-b6c9-5145427b22f3", "name": "load_p1rlv12557_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fe4d6ae-cca5-476c-981a-a1dcd27b1e84"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e6120965-3163-44d8-8795-e883b0e34afe"}}}}, {"uuid": "fceb259d-954e-4c0d-a150-78ac533baca1", "name": "e0c5a270-abfa-4883-8baf-ed86fb59ffb0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.408318732620361, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.41814988562464883, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "94430f1e-1b47-4835-9d87-a26d30ac25f4", "name": "5d608f62-d235-48f6-905d-fb4ad378a38e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fceb259d-954e-4c0d-a150-78ac533baca1"}}}]}, {"uuid": "b52d40e1-7dd4-4d66-932d-26e4adbf6420", "name": "load_p1rlv12558_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a427f20-861a-4616-9443-265beaeccca3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "94430f1e-1b47-4835-9d87-a26d30ac25f4"}}}}, {"uuid": "b67cc3a7-efc2-4b73-8760-243e73ec84e9", "name": "a519c9c5-243d-4164-8d71-d9ebf568709c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.408318732620361, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.41814988562464883, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7dad946a-64e6-471e-9d5a-f5c2b56b4453", "name": "28666f42-b2e8-4084-a71f-177b3f358f9a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b67cc3a7-efc2-4b73-8760-243e73ec84e9"}}}]}, {"uuid": "32210c0c-5a99-44d3-89da-dcd3a4957933", "name": "load_p1rlv12558_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a427f20-861a-4616-9443-265beaeccca3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7dad946a-64e6-471e-9d5a-f5c2b56b4453"}}}}, {"uuid": "a7aeb239-b12f-43d8-9254-ceaa8ce5e63e", "name": "7d4a04f8-e89e-4c6a-baff-658b68f7e66d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4ef0e256-0104-4670-ab8e-66c781b92406", "name": "dae4cac6-0ccf-403a-8a0b-4866a8108bc2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a7aeb239-b12f-43d8-9254-ceaa8ce5e63e"}}}]}, {"uuid": "01613cf8-4c62-4ab0-aaf7-05cb942bf041", "name": "load_p1rlv12559_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a47101-b6df-473e-9c7b-96e076c17931"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4ef0e256-0104-4670-ab8e-66c781b92406"}}}}, {"uuid": "512b1fd5-c86c-41ad-a872-0d065db783c7", "name": "65a5f5f0-0ae7-4772-9834-824f5cd68277_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ac9edb43-7944-49af-972a-36bc7f104596", "name": "450e2d61-d419-4788-9fe1-76e179c9155e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "512b1fd5-c86c-41ad-a872-0d065db783c7"}}}]}, {"uuid": "f31a4f65-f744-4d57-848a-782d2ce69a80", "name": "load_p1rlv12559_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a47101-b6df-473e-9c7b-96e076c17931"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ac9edb43-7944-49af-972a-36bc7f104596"}}}}, {"uuid": "8d05d7db-5906-45a2-b1df-57fb6360a6b9", "name": "f2f96b59-653b-4115-b388-497ff52e86b5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4cff9875-7386-458a-9b64-80156936c140", "name": "5af06e9b-23e0-4f6e-a121-7535fd7f88ca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8d05d7db-5906-45a2-b1df-57fb6360a6b9"}}}]}, {"uuid": "c907954e-7703-4c1f-9a10-7dfbbb090930", "name": "load_p1rlv12562_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b0417d3-820d-4daa-aec5-3dcf34e40e00"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4cff9875-7386-458a-9b64-80156936c140"}}}}, {"uuid": "31402909-c881-44f6-9600-4af29e18b80c", "name": "258b099f-96f3-42c9-97ce-6c940296fb86_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d734fea1-2101-4015-8765-d044ecca754e", "name": "718893c7-d6f5-46c0-89e9-ddff0d94b2ef", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "31402909-c881-44f6-9600-4af29e18b80c"}}}]}, {"uuid": "7d67f5e1-9d72-499d-a95a-be3277402376", "name": "load_p1rlv12562_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b0417d3-820d-4daa-aec5-3dcf34e40e00"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d734fea1-2101-4015-8765-d044ecca754e"}}}}, {"uuid": "57030d1d-0515-409b-aa4a-387c467d26ac", "name": "1a257e80-dfde-40c4-aa55-d37da79da837_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "350a7ad6-f872-4619-ae5f-cfd457befd45", "name": "1a257e80-dfde-40c4-aa55-d37da79da837_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "81199978-dcd1-47b2-8456-f39100ae2842", "name": "1a257e80-dfde-40c4-aa55-d37da79da837_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "320af1ec-76c0-4573-9c87-c3be63bcca88", "name": "6dade334-e8c5-4f6d-8279-8cd008e9a44d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "57030d1d-0515-409b-aa4a-387c467d26ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "350a7ad6-f872-4619-ae5f-cfd457befd45"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "81199978-dcd1-47b2-8456-f39100ae2842"}}}]}, {"uuid": "17b19812-d10c-4cc3-8e0b-b93942f5974c", "name": "load_p1rlv12567", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29476f95-f85b-4843-a847-3d9d99da3b74"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "320af1ec-76c0-4573-9c87-c3be63bcca88"}}}}, {"uuid": "f44bfd34-ad29-4174-a161-329b1224269d", "name": "36a08b46-936f-47a7-a34b-83acf6359197_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1813646779377422, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20173832232537287, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b8f01aa2-00fd-4dcd-95d3-ee92c7dc38da", "name": "ce99f5ba-9e66-476d-9b98-d5895b6afb7a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f44bfd34-ad29-4174-a161-329b1224269d"}}}]}, {"uuid": "8c1c77d8-e76c-4eda-bff9-22efc95cca94", "name": "load_p1rlv12936_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "019e419c-9f88-455a-bf48-b89531ed9e51"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b8f01aa2-00fd-4dcd-95d3-ee92c7dc38da"}}}}, {"uuid": "7f3d1ad9-9edb-4501-95e7-11dd23a50986", "name": "f8e1f177-5d01-4890-bfdc-99a3c60f7353_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1813646779377422, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20173832232537287, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "59dc5206-5cf4-4a62-8f4a-564ccced3760", "name": "7e6fccaf-608c-460d-b620-86aa98026b84", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7f3d1ad9-9edb-4501-95e7-11dd23a50986"}}}]}, {"uuid": "64ecfe23-c977-4298-9dc8-22e8d727ecc3", "name": "load_p1rlv12936_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "019e419c-9f88-455a-bf48-b89531ed9e51"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "59dc5206-5cf4-4a62-8f4a-564ccced3760"}}}}, {"uuid": "afa36572-c7ae-4d30-a2cf-34a94041a92f", "name": "95dd7527-7120-47c6-9afa-d40a630910f0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.674261199298095, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1525334183561808, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c66704e3-e385-47ce-b33a-e2c4375ef14e", "name": "7b00e015-39f0-4fc3-86ed-c4037ef252ea", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "afa36572-c7ae-4d30-a2cf-34a94041a92f"}}}]}, {"uuid": "a215654e-7a13-4de0-8afb-2f584ea13270", "name": "load_p1rlv12959_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8418804f-aad5-49df-9916-f427da5089c1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c66704e3-e385-47ce-b33a-e2c4375ef14e"}}}}, {"uuid": "ec3f59ba-2ece-4e43-8236-8c9de91b7627", "name": "5341f2d5-824e-4ce2-a368-edbf3ae10d37_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.674261199298095, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1525334183561808, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5dfda74d-6533-41b2-b54f-7101f1bd6c06", "name": "63791f0a-1239-4534-a7b3-c82111e806d7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ec3f59ba-2ece-4e43-8236-8c9de91b7627"}}}]}, {"uuid": "a9e2e550-8519-457a-9432-96ca8f3494ab", "name": "load_p1rlv12959_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8418804f-aad5-49df-9916-f427da5089c1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5dfda74d-6533-41b2-b54f-7101f1bd6c06"}}}}, {"uuid": "6bafed9c-a79a-43e6-a2a6-6262cbf57402", "name": "6465f966-6ad2-4637-b178-c99221f13579_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.622949952431687, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7401570066486144, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aa680a67-4712-49b6-a6ef-d2abb1acc56c", "name": "c0e0b38a-4d53-4faf-bc78-726feff62d84", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6bafed9c-a79a-43e6-a2a6-6262cbf57402"}}}]}, {"uuid": "a267a065-bc37-434d-b77a-bd9be5993b1e", "name": "load_p1rlv12971_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be845651-8e1c-4b6d-8633-fcbdfb1fd5d4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aa680a67-4712-49b6-a6ef-d2abb1acc56c"}}}}, {"uuid": "d9161e28-a0e8-4632-ae36-7b0369feafe5", "name": "ecbbdcd3-87d4-4093-8c08-7131f570fb59_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.622949952431687, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7401570066486144, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9836cc02-f8d9-4b59-aaeb-a80e647f8b53", "name": "5183ea73-8c25-4849-b8c8-ac8d8262be00", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d9161e28-a0e8-4632-ae36-7b0369feafe5"}}}]}, {"uuid": "aa3223c1-16c1-4b3f-99e7-4134ca4d6bf0", "name": "load_p1rlv12971_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be845651-8e1c-4b6d-8633-fcbdfb1fd5d4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9836cc02-f8d9-4b59-aaeb-a80e647f8b53"}}}}, {"uuid": "bf2243f3-2f82-411a-a167-14dd3432096e", "name": "0e011f34-06de-4749-9462-166fa6b5bab8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.629144238694082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9654448182756213, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0e6b89e2-09ac-43e4-9fdf-5d1f0467c088", "name": "6d835633-768b-4507-aef7-efebcacfcf21", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bf2243f3-2f82-411a-a167-14dd3432096e"}}}]}, {"uuid": "ef085e54-6201-46d3-8f05-3179724d75da", "name": "load_p1rlv13043_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3072c6c-3a40-4e49-bd00-febc8268b135"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0e6b89e2-09ac-43e4-9fdf-5d1f0467c088"}}}}, {"uuid": "048c2b39-a731-4873-a791-7b25cf4be610", "name": "da303c9d-b1f7-4042-8a61-3318d0388810_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.629144238694082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9654448182756213, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "68485ccc-34ca-4e0d-b041-cf3abda83f2c", "name": "9503fa22-df99-4b16-9624-ba5058855d48", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "048c2b39-a731-4873-a791-7b25cf4be610"}}}]}, {"uuid": "cf1311b1-6044-4a3b-b741-8eba3f6a730f", "name": "load_p1rlv13043_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3072c6c-3a40-4e49-bd00-febc8268b135"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "68485ccc-34ca-4e0d-b041-cf3abda83f2c"}}}}, {"uuid": "29ea63e7-0679-4c22-8880-178658313e08", "name": "b0f23629-383c-4a33-8600-91e1c7d72d0b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.67656735172194, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8569955192100605, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a9952cc1-e7a5-411b-bc2b-9b562df4ea90", "name": "2018957d-e361-4656-a49e-7af6f7dd0ec2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "29ea63e7-0679-4c22-8880-178658313e08"}}}]}, {"uuid": "1ecebcd9-1364-4d70-ad28-909bb5b9d8fa", "name": "load_p1rlv13044_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa31c772-8460-4624-a123-64b87ca8d332"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a9952cc1-e7a5-411b-bc2b-9b562df4ea90"}}}}, {"uuid": "72973c4b-1480-4f11-b02c-02b2e34a71c3", "name": "adebbaae-4278-4f65-999f-fd3d7c4d898c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.67656735172194, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8569955192100605, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b55a038b-402f-4d21-8478-cd30f0dffba0", "name": "5b690348-d90e-445d-8fed-7350db417d1e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72973c4b-1480-4f11-b02c-02b2e34a71c3"}}}]}, {"uuid": "abb52718-5636-4abc-9e4b-b1ad17398d48", "name": "load_p1rlv13044_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa31c772-8460-4624-a123-64b87ca8d332"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b55a038b-402f-4d21-8478-cd30f0dffba0"}}}}, {"uuid": "3627100b-bd13-4957-bf7f-5b3dcb399273", "name": "2f7e63ee-606e-4006-8054-fa280fed04a2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.927062407458527, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.5614641711041375, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9696f3af-6d44-4089-8061-b37461d4c4bf", "name": "dcca069b-2167-4bef-9609-3a4a5e037504", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3627100b-bd13-4957-bf7f-5b3dcb399273"}}}]}, {"uuid": "beb721c2-d839-4335-bb0b-504d29a38675", "name": "load_p1rlv13045_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6070414d-09e7-48a7-aec0-c105cc0f1a93"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9696f3af-6d44-4089-8061-b37461d4c4bf"}}}}, {"uuid": "23f1d753-acb9-4529-8473-9d9b923aae89", "name": "838a49c5-8699-4ad8-bef6-e7c55e73e980_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.927062407458527, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.5614641711041375, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9e38c316-0bf1-4c33-b03d-6c2bf7a7b6f4", "name": "8496860e-e0bc-4f29-904a-b4ae24142a88", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "23f1d753-acb9-4529-8473-9d9b923aae89"}}}]}, {"uuid": "39d37fbc-2cb3-45bc-8cf5-cd01fbc253ab", "name": "load_p1rlv13045_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6070414d-09e7-48a7-aec0-c105cc0f1a93"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9e38c316-0bf1-4c33-b03d-6c2bf7a7b6f4"}}}}, {"uuid": "3d8a2220-4e4f-4e81-9717-bb8186a3a84a", "name": "aaf7daa9-44e0-4720-816a-bd6211d51e77_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 15.279136617573831, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5014115237228067, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8fed5cf1-3790-4d6a-abea-a0cdedfcbf66", "name": "86e517e9-c448-4f71-a223-b4a9e03e56ca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3d8a2220-4e4f-4e81-9717-bb8186a3a84a"}}}]}, {"uuid": "d201c1a8-8405-407a-b693-d3e6ecbdfc3b", "name": "load_p1rlv13046_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5edc15fb-49d5-4052-8fad-4979578f6ed1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8fed5cf1-3790-4d6a-abea-a0cdedfcbf66"}}}}, {"uuid": "9693a4ba-33c3-4686-95d8-bd54caac41d7", "name": "192aec90-8be0-407e-8eb1-02d103b8aa8f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 15.279136617573831, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5014115237228067, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6101ba57-b6a3-4b6f-96e4-155b9aaec470", "name": "fa37179a-b466-4601-80e7-601e4e1ea5e6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9693a4ba-33c3-4686-95d8-bd54caac41d7"}}}]}, {"uuid": "c0555aca-c68c-4f8e-9f96-4d02f0aa6ac2", "name": "load_p1rlv13046_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5edc15fb-49d5-4052-8fad-4979578f6ed1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6101ba57-b6a3-4b6f-96e4-155b9aaec470"}}}}, {"uuid": "e4bb654e-d037-44c7-93fb-136954260713", "name": "aedd0946-c9f5-4c4e-9a2d-a162cffd94db_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3374419606114465, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8276898777002473, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "336d306b-9868-4071-b9ad-f2f0b5a68ee8", "name": "bf70eb87-479c-41be-acc2-1f40468a8d77", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e4bb654e-d037-44c7-93fb-136954260713"}}}]}, {"uuid": "a8845610-255f-4497-9140-7e0b22d0ea41", "name": "load_p1rlv13047_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4209bdad-276f-4e07-93e0-78b162ce95cf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "336d306b-9868-4071-b9ad-f2f0b5a68ee8"}}}}, {"uuid": "0e5dc84b-05ee-499d-b21a-da930b8ff0e7", "name": "0f30c492-a1c2-433d-932c-4fadbc3cda54_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3374419606114465, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8276898777002473, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fce9ecb2-402a-4b36-b60f-4380bc572ff2", "name": "97aad36b-aaba-4ba4-8b0f-69233cde3781", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0e5dc84b-05ee-499d-b21a-da930b8ff0e7"}}}]}, {"uuid": "ea5f208e-4405-479a-9249-fdd564e27ac7", "name": "load_p1rlv13047_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4209bdad-276f-4e07-93e0-78b162ce95cf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fce9ecb2-402a-4b36-b60f-4380bc572ff2"}}}}, {"uuid": "a2344f4d-580f-4d1f-8ca7-96074f3a11ca", "name": "ece2f7cf-fbf5-46d5-89e6-03413649b91b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3862445486686554, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0100117110086289, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2ab11757-34f2-4b89-b71a-6fdd1a84a1db", "name": "c0c1eaed-9da8-478f-a901-91ac11e47dd5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a2344f4d-580f-4d1f-8ca7-96074f3a11ca"}}}]}, {"uuid": "da3b6c00-95ce-4543-b2b6-ad5d48e8ed50", "name": "load_p1rlv13048_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "569078be-37c2-4c05-8455-91945eb7fdb9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2ab11757-34f2-4b89-b71a-6fdd1a84a1db"}}}}, {"uuid": "6ccf68b4-da02-4d62-aef9-3c67796369ee", "name": "216328c0-676a-4590-9934-5ddf303cf7d0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3862445486686554, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0100117110086289, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6c2cb862-2147-4b66-9321-30946bf3fddf", "name": "c93767ca-1ca8-472b-9e64-148c1794dace", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6ccf68b4-da02-4d62-aef9-3c67796369ee"}}}]}, {"uuid": "6fccad50-53ea-47b2-b9a4-c004ab2e0953", "name": "load_p1rlv13048_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "569078be-37c2-4c05-8455-91945eb7fdb9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6c2cb862-2147-4b66-9321-30946bf3fddf"}}}}, {"uuid": "88a28a37-de8a-40f3-85a8-ecf02873796a", "name": "8e5e686d-f46a-4930-adcf-16b20d576e59_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.734495706390117, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.8488351310797768, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "02143f59-781d-4f3c-ae65-f5cdf7219e27", "name": "a05253a1-6c79-4fe6-8718-0385e58be912", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "88a28a37-de8a-40f3-85a8-ecf02873796a"}}}]}, {"uuid": "f24deddc-0423-4117-9703-7a99a11e928c", "name": "load_p1rlv13049_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ed85192-4c5a-4c15-ba21-1ba883b03ddd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "02143f59-781d-4f3c-ae65-f5cdf7219e27"}}}}, {"uuid": "a1c08b21-8534-4b31-8cb2-a5d67b33899e", "name": "a63d29ec-7a7d-4e93-841b-a67584b88102_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.734495706390117, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.8488351310797768, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "620b6660-d420-44fc-a878-b0ce12065187", "name": "2326f173-a2c2-4284-84a3-088d473aad62", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a1c08b21-8534-4b31-8cb2-a5d67b33899e"}}}]}, {"uuid": "216972e7-f384-4784-97d7-16866891173d", "name": "load_p1rlv13049_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ed85192-4c5a-4c15-ba21-1ba883b03ddd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "620b6660-d420-44fc-a878-b0ce12065187"}}}}, {"uuid": "5330a24c-1c74-4447-91f5-72636276f9cc", "name": "7c121eb7-6fec-4992-bc39-b0896d5a6423_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 23.2179949774968, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.953694721257675, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6aa3263e-c151-4899-9e82-4a851d6b2b6d", "name": "7c121eb7-6fec-4992-bc39-b0896d5a6423_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 23.2179949774968, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.953694721257675, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c69ddaa1-e2dd-411d-9010-ab6cd872259d", "name": "7c121eb7-6fec-4992-bc39-b0896d5a6423_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 23.2179949774968, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.953694721257675, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "54f818ce-e227-429b-81c2-73c52d992eb5", "name": "0f41eb01-df7d-4d64-b994-d868d16dd02d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5330a24c-1c74-4447-91f5-72636276f9cc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6aa3263e-c151-4899-9e82-4a851d6b2b6d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c69ddaa1-e2dd-411d-9010-ab6cd872259d"}}}]}, {"uuid": "82e9cc65-bb9f-47af-8448-b3675c52f170", "name": "load_p1rlv13050", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "051eba03-4728-4626-8add-5410b5326dc7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "54f818ce-e227-429b-81c2-73c52d992eb5"}}}}, {"uuid": "3c5de08d-4489-4eff-9d3a-df139e6261fa", "name": "b6c5b2c4-f466-45a3-8919-d20bc877b7ca_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.295504020074436, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.753636562958712, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d96577ec-a347-4d9e-b275-74c4e3582e5a", "name": "c16beac3-a33a-4ec1-b3c2-6dd358eb7e26", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3c5de08d-4489-4eff-9d3a-df139e6261fa"}}}]}, {"uuid": "deba2370-2c00-4278-9e40-74318b254dc7", "name": "load_p1rlv13051_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9a855b0-538e-4fab-91f1-93b4ece09409"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d96577ec-a347-4d9e-b275-74c4e3582e5a"}}}}, {"uuid": "2277f042-b321-4549-85c5-bfeefe010c0f", "name": "05b5aa46-f5c1-46a7-a7be-a0916dc3e831_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.295504020074436, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.753636562958712, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "386bd9d3-bf89-4d7f-95d5-9484beb56654", "name": "9ff705f6-657e-4c3b-a184-d722838b010d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2277f042-b321-4549-85c5-bfeefe010c0f"}}}]}, {"uuid": "e9e13a15-8f79-48f8-b00d-112c0955c7ff", "name": "load_p1rlv13051_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9a855b0-538e-4fab-91f1-93b4ece09409"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "386bd9d3-bf89-4d7f-95d5-9484beb56654"}}}}, {"uuid": "e47fc9f6-a620-41d6-8e5e-a4dea78f1d8c", "name": "02707f24-6de0-4f61-9067-fc376ceb4c35_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 19.860755218124574, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.283352762304049, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "90d2a991-1be9-4d3d-b25c-d641f5852ce0", "name": "98b94bea-0497-48c9-83cf-43dc2f58673e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e47fc9f6-a620-41d6-8e5e-a4dea78f1d8c"}}}]}, {"uuid": "c45e9911-1996-4701-87fe-231c8d794fe3", "name": "load_p1rlv13052_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86d59550-d7c8-47e1-a6bc-14b2d50de58c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "90d2a991-1be9-4d3d-b25c-d641f5852ce0"}}}}, {"uuid": "0b19b038-939c-4e2e-8045-86bfef6c145a", "name": "b60560c0-d5ed-443f-ae13-4cc320357fa6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 19.860755218124574, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.283352762304049, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fe9ce19d-3988-4f6f-acf3-8ac26188214c", "name": "21ef59b3-9520-42d9-a4b4-7d46fe81973d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0b19b038-939c-4e2e-8045-86bfef6c145a"}}}]}, {"uuid": "94a58535-40fd-430f-a363-0df23068f8eb", "name": "load_p1rlv13052_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86d59550-d7c8-47e1-a6bc-14b2d50de58c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fe9ce19d-3988-4f6f-acf3-8ac26188214c"}}}}, {"uuid": "8c55e953-e9d0-4f9a-afda-2b8357ad3322", "name": "e5be8e83-343d-4fe3-bd2d-f1ea52abcf56_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.272941497663945, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5660410395064467, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ec02be12-6aad-48e2-a97a-42a76367cb01", "name": "f2b0c48e-02b6-40cf-8f81-327201ddb0b1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8c55e953-e9d0-4f9a-afda-2b8357ad3322"}}}]}, {"uuid": "b030444d-c176-4df9-93ed-356fa73af275", "name": "load_p1rlv13053_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e058437-0138-4305-a33e-d8fa61aed8cc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ec02be12-6aad-48e2-a97a-42a76367cb01"}}}}, {"uuid": "b9a4594e-ecff-4fe1-abef-288a6ec861c7", "name": "a5ccbeed-776c-4cb9-9e01-d994993b293b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.272941497663945, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5660410395064467, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c7e076c8-071b-44a4-82b9-3a65877b8dfa", "name": "4b5acf6d-494a-47de-ad73-bfda2139e333", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b9a4594e-ecff-4fe1-abef-288a6ec861c7"}}}]}, {"uuid": "2593ff8d-6b0c-41be-bf36-255ad70efd32", "name": "load_p1rlv13053_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e058437-0138-4305-a33e-d8fa61aed8cc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c7e076c8-071b-44a4-82b9-3a65877b8dfa"}}}}, {"uuid": "b0c56a5f-1836-4722-a7a7-f077bf3f4645", "name": "d029c9ef-058f-4751-b3cd-a83bf3b24772_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.124330522658403, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7653447086077897, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "98e6961c-f75a-4769-bfdd-47154e878802", "name": "5b818057-a251-4108-ba28-169f909cd66b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b0c56a5f-1836-4722-a7a7-f077bf3f4645"}}}]}, {"uuid": "9839d392-3d5d-4f32-8fb9-d9cdcecf9708", "name": "load_p1rlv13054_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21c6ea4f-ec9d-424e-8743-7175408f9e2c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "98e6961c-f75a-4769-bfdd-47154e878802"}}}}, {"uuid": "13880019-47f5-4b84-9104-ca8a4447df61", "name": "ddc63b09-7b10-4163-87cc-483774534e70_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.124330522658403, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7653447086077897, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "11e31fd7-ec52-4f61-9efb-5a0f0e2a8a45", "name": "cc0e63a9-f9df-434a-bbf6-394f9c1a79ac", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "13880019-47f5-4b84-9104-ca8a4447df61"}}}]}, {"uuid": "4e56214a-a749-4596-8cee-c667bf524484", "name": "load_p1rlv13054_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21c6ea4f-ec9d-424e-8743-7175408f9e2c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "11e31fd7-ec52-4f61-9efb-5a0f0e2a8a45"}}}}, {"uuid": "03c39f62-f346-4ecf-87da-b9ca705e9875", "name": "9928165b-4e5b-4c16-8a43-36d49a23f7a1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.470164086158317, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2411725730358465, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c5708940-7781-463f-bcd1-37b6c01a4cf1", "name": "9746de90-03dd-4bd0-9bcb-c40970aad705", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "03c39f62-f346-4ecf-87da-b9ca705e9875"}}}]}, {"uuid": "dbd96bdb-7497-4e12-a129-f75678931540", "name": "load_p1rlv13055_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387df3d3-5f03-47f4-8b16-bea8815e63d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c5708940-7781-463f-bcd1-37b6c01a4cf1"}}}}, {"uuid": "6f125292-8e7d-415c-87ba-4b4ba7d74463", "name": "b9af170a-b3b6-4e59-9859-9f671b00ecdb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.470164086158317, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2411725730358465, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c10703b2-a476-4671-9c7d-3bc15b542600", "name": "93dd0309-9f55-4a16-adda-c7157a769eac", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6f125292-8e7d-415c-87ba-4b4ba7d74463"}}}]}, {"uuid": "1cf14206-e3aa-4595-b8ce-69a46738d4b2", "name": "load_p1rlv13055_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387df3d3-5f03-47f4-8b16-bea8815e63d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c10703b2-a476-4671-9c7d-3bc15b542600"}}}}, {"uuid": "99c97419-8203-4111-ab56-df4a04e8149f", "name": "b93feca9-d48c-4c0c-b938-910cd5a29adf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.8145950466373417, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09093602970127403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f4184d92-ab07-4d9b-803f-435931250b82", "name": "ef23f723-a264-4e32-9a5d-84f6b35da717", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "99c97419-8203-4111-ab56-df4a04e8149f"}}}]}, {"uuid": "284761d0-ff7d-48c2-8436-493918426886", "name": "load_p1rlv13056_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16584dfd-537d-4b0d-a651-c73d0beabc6d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f4184d92-ab07-4d9b-803f-435931250b82"}}}}, {"uuid": "81b1de48-f250-4a8e-9b53-21944e42f4ed", "name": "70ec6cdc-04cb-4891-bdeb-6b8d57f70743_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.8145950466373417, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09093602970127403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "19359e76-6088-4b0e-8f47-c33f8a19d2f8", "name": "ace47199-3291-4db6-bc3b-65e5536c2fd6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "81b1de48-f250-4a8e-9b53-21944e42f4ed"}}}]}, {"uuid": "367c65ab-12a7-4272-8839-3190caeb0b1e", "name": "load_p1rlv13056_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16584dfd-537d-4b0d-a651-c73d0beabc6d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "19359e76-6088-4b0e-8f47-c33f8a19d2f8"}}}}, {"uuid": "6c5c1197-8967-44f0-85b2-dd43d1bf8829", "name": "fcb5b0f9-8055-434e-a248-0b9d1358fa16_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b535f1cc-a786-4654-808f-1f463aae6dc8", "name": "841c3407-202a-4de9-8727-64ed789e4708", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c5c1197-8967-44f0-85b2-dd43d1bf8829"}}}]}, {"uuid": "31c3c8e3-e973-44e8-8690-5b04d68c366f", "name": "load_p1rlv13057_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c63d163-75bd-4d91-bcfa-229a2e331b1f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b535f1cc-a786-4654-808f-1f463aae6dc8"}}}}, {"uuid": "79a4a57b-5123-4f98-8e18-1d35c301ddd6", "name": "bc86e892-aced-4a06-b06e-d828beeab8ac_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "85960692-2cde-4d5a-b06e-e13af7db5812", "name": "fb457142-7b1a-4c62-a316-43045a4c6b27", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "79a4a57b-5123-4f98-8e18-1d35c301ddd6"}}}]}, {"uuid": "fd8f7923-db76-49bc-a8a3-66b4445c641e", "name": "load_p1rlv13057_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c63d163-75bd-4d91-bcfa-229a2e331b1f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "85960692-2cde-4d5a-b06e-e13af7db5812"}}}}, {"uuid": "72ea28b0-b695-4847-8b76-01579e4b31e6", "name": "cd345cd3-f1ff-41f5-a1a3-c11ab919a3e8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.875608242018149, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1961787734858456, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e9e358ae-8ebc-4bbc-aacf-73d7af4f2b43", "name": "468eefb5-0eb9-4a7c-a496-c98bd42b4734", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72ea28b0-b695-4847-8b76-01579e4b31e6"}}}]}, {"uuid": "a5e733fd-c2a1-42ae-a63b-4b11bfa9d4ad", "name": "load_p1rlv13058_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c83997dc-872f-494f-8c8a-7266c854fc48"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e9e358ae-8ebc-4bbc-aacf-73d7af4f2b43"}}}}, {"uuid": "fa7d9d10-6d78-4c79-8731-d4c36a133c7b", "name": "7d9a7113-b197-45a8-88c4-551125329b8a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.875608242018149, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1961787734858456, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7d1c59aa-705c-45c6-b82f-b7178e590441", "name": "a3343969-c521-4491-8340-33b943ea446a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fa7d9d10-6d78-4c79-8731-d4c36a133c7b"}}}]}, {"uuid": "fbd1c302-0e7e-41ea-8740-e1992463426f", "name": "load_p1rlv13058_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c83997dc-872f-494f-8c8a-7266c854fc48"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7d1c59aa-705c-45c6-b82f-b7178e590441"}}}}, {"uuid": "f0d8f92a-2aa8-4431-b312-ceb670228bc3", "name": "6e80263e-b0f6-4134-8069-1f1b7dbdc9d0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.516258392707745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.82351986644914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8d6d47de-9c11-42bd-853a-3d70debb739a", "name": "d4eb75ca-db27-4f11-a549-7e032883373b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f0d8f92a-2aa8-4431-b312-ceb670228bc3"}}}]}, {"uuid": "1c110a7c-5cdc-43a4-b1f8-747810ee5d26", "name": "load_p1rlv13059_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a1779b5b-1a6c-4511-9d4b-88026b430173"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8d6d47de-9c11-42bd-853a-3d70debb739a"}}}}, {"uuid": "8392a5f2-8483-4178-8754-587db4aabfb1", "name": "f1e5901c-94b7-463f-9101-552c870f7ba5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.516258392707745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.82351986644914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "818d8732-8073-4359-aa2a-4354c7097e22", "name": "3fd08c63-7fde-40fd-9774-52d88dda9756", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8392a5f2-8483-4178-8754-587db4aabfb1"}}}]}, {"uuid": "baecbf82-3a54-4bec-8e4f-b5150a2aaa5c", "name": "load_p1rlv13059_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a1779b5b-1a6c-4511-9d4b-88026b430173"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "818d8732-8073-4359-aa2a-4354c7097e22"}}}}, {"uuid": "4a61925b-63ad-4878-bc40-638e85e45994", "name": "5aa02a8b-c7a8-436e-a0a9-b6678a5c7f62_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3225810719994042, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7007930471414398, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1bfb56c0-4096-4c8c-8132-c0d23ee1f565", "name": "a962c033-de0a-49a5-938a-78efb020e111", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4a61925b-63ad-4878-bc40-638e85e45994"}}}]}, {"uuid": "a20be27f-4923-49db-83c7-31bc05844f05", "name": "load_p1rlv13060_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8767a040-da31-48d9-9473-0941856bcedc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1bfb56c0-4096-4c8c-8132-c0d23ee1f565"}}}}, {"uuid": "a0650809-8db7-442f-9baf-4b1823c29dac", "name": "11a2873e-9d09-40a4-88ec-071c2a439041_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3225810719994042, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7007930471414398, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "11e7c63b-d762-436a-ab74-35f68452aa97", "name": "c22d50fb-5daa-45ee-ae34-1913bc061277", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a0650809-8db7-442f-9baf-4b1823c29dac"}}}]}, {"uuid": "54f04642-4939-42fd-84ee-dc703d2e192c", "name": "load_p1rlv13060_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8767a040-da31-48d9-9473-0941856bcedc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "11e7c63b-d762-436a-ab74-35f68452aa97"}}}}, {"uuid": "f09616a9-d057-472b-be37-d3dde12abaa4", "name": "6818e893-548b-4084-ab88-2c7a3f9b4ae8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.20841006074213, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.2893238389393127, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "05d08ee4-9edf-462f-ab42-6f6ab946315a", "name": "6818e893-548b-4084-ab88-2c7a3f9b4ae8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.20841006074213, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.2893238389393127, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5b5f5f56-b919-4163-9f77-d0372d0dfc9c", "name": "6818e893-548b-4084-ab88-2c7a3f9b4ae8_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.20841006074213, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.2893238389393127, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7cbd7f03-3a65-4248-ac54-402c42382bd1", "name": "18abeb5f-69d6-4190-8139-c09f1ecb7b47", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f09616a9-d057-472b-be37-d3dde12abaa4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "05d08ee4-9edf-462f-ab42-6f6ab946315a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b5f5f56-b919-4163-9f77-d0372d0dfc9c"}}}]}, {"uuid": "aefdeb5a-7e28-4e59-a971-9e1880d00e58", "name": "load_p1rlv13061", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d46fd47-37f5-48a0-ba0d-d0746e6e6da3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7cbd7f03-3a65-4248-ac54-402c42382bd1"}}}}, {"uuid": "6a5e0cda-f071-41b3-89c3-bc3895ae79fd", "name": "0d619baf-e5ab-4247-ae0b-9be1dc720473_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c7020c42-d410-4138-b783-2833e5b95e5d", "name": "99999fa5-08e3-4da4-a649-53dbbd1068f7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6a5e0cda-f071-41b3-89c3-bc3895ae79fd"}}}]}, {"uuid": "95215704-3da1-4ebf-82f9-6059829ad086", "name": "load_p1rlv13062_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d2fa164-4c03-4bcd-a386-749ccd4e9001"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c7020c42-d410-4138-b783-2833e5b95e5d"}}}}, {"uuid": "46910cb5-2278-4ebc-b869-a4176999f6a2", "name": "8019d56f-4594-4922-9645-636324369ed9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "80fc95da-435d-45a0-a2c9-560a5a2f6aa0", "name": "27053b5a-0961-4ef7-a1fc-1cd4ecca27c1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "46910cb5-2278-4ebc-b869-a4176999f6a2"}}}]}, {"uuid": "b9c24b71-6e11-4019-8154-506058e4c412", "name": "load_p1rlv13062_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d2fa164-4c03-4bcd-a386-749ccd4e9001"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "80fc95da-435d-45a0-a2c9-560a5a2f6aa0"}}}}, {"uuid": "f455affc-aa35-47f2-9204-d82535afe51e", "name": "f7144831-4e15-4ed2-aedc-52b063299ed5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7083181921938193, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5666922324635131, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d410a840-d501-424e-866e-c57fd35ed41b", "name": "62e4edf4-f84f-4ca5-b758-65ce2968d898", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f455affc-aa35-47f2-9204-d82535afe51e"}}}]}, {"uuid": "e1bdea92-19fa-4287-b18d-26335d377399", "name": "load_p1rlv13185_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c29c3206-b71d-41d1-8ad7-a693c8c25d4d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d410a840-d501-424e-866e-c57fd35ed41b"}}}}, {"uuid": "2e60e5d6-561c-42b0-8601-c04b7998b6c8", "name": "352fe72c-c94f-441e-84ce-c82499836e28_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7083181921938193, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5666922324635131, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f4f3c19-5175-404f-9c92-e25705eb2ba8", "name": "defe891f-b26d-4dbc-9a31-c5346d2e5ce6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2e60e5d6-561c-42b0-8601-c04b7998b6c8"}}}]}, {"uuid": "38d145c4-18bd-4d9e-a258-5ecd2fd7429b", "name": "load_p1rlv13185_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c29c3206-b71d-41d1-8ad7-a693c8c25d4d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f4f3c19-5175-404f-9c92-e25705eb2ba8"}}}}, {"uuid": "cb8dd4b9-478e-47ca-9faa-4093149e4ba4", "name": "6d4551ec-1524-4d41-a79c-0698ba79ae98_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.774034588817963, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.005441618856208, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0367dad2-f61f-42d8-84b1-beb3a9f41e18", "name": "7ec19d5f-61eb-4752-b91e-7418eebc93a8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cb8dd4b9-478e-47ca-9faa-4093149e4ba4"}}}]}, {"uuid": "c488ff8d-b283-48e1-926a-a87c8c8c974d", "name": "load_p1rlv13187_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ffbd17b6-b1a2-4e55-9052-67a84419bb9d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0367dad2-f61f-42d8-84b1-beb3a9f41e18"}}}}, {"uuid": "44ac4961-909d-4886-bad7-ad68cddce4d2", "name": "b5cd8e31-7da9-43c0-a8b3-2d09ba56c7c0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.774034588817963, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.005441618856208, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "71866af3-3b03-49b5-8ed8-2fcb0c02fb5d", "name": "0a7ca848-f6e4-4330-b1ba-bcc12a3de282", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "44ac4961-909d-4886-bad7-ad68cddce4d2"}}}]}, {"uuid": "7f56d7c7-f838-4fcb-89c1-2d348c29a4c7", "name": "load_p1rlv13187_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ffbd17b6-b1a2-4e55-9052-67a84419bb9d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "71866af3-3b03-49b5-8ed8-2fcb0c02fb5d"}}}}, {"uuid": "90accc6c-537a-4e94-b3d9-599bc4d64d05", "name": "4038a0af-b705-4717-9396-d519d296d2bd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.028781788264419, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6709073147144231, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1f1260f7-8479-4de9-9e97-75aad039f9d2", "name": "b06a4187-870a-460c-b8eb-49f511949b47", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "90accc6c-537a-4e94-b3d9-599bc4d64d05"}}}]}, {"uuid": "abb8d875-6105-4ed3-8a3c-c50530500a31", "name": "load_p1rlv13188_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67ffcd9f-ba90-4da7-b3b6-46310e321590"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1f1260f7-8479-4de9-9e97-75aad039f9d2"}}}}, {"uuid": "3ed24d70-5c45-4cd8-92ce-2d822e741459", "name": "e40b61a4-2e7d-42de-a2ec-5134d7e60e86_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.028781788264419, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6709073147144231, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "66d43c17-fd3c-4cff-beed-d3cf878028df", "name": "908786ce-d194-4c28-a6cb-a687c3d12f93", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3ed24d70-5c45-4cd8-92ce-2d822e741459"}}}]}, {"uuid": "9719e5cb-9795-4a7a-bdea-f89f7f132c4c", "name": "load_p1rlv13188_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67ffcd9f-ba90-4da7-b3b6-46310e321590"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "66d43c17-fd3c-4cff-beed-d3cf878028df"}}}}, {"uuid": "749e6bd0-8c6d-4d4f-be52-4afd163f1e24", "name": "c9a3c089-66dc-4582-8ede-10c963e974e4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6702758059963014, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.7275069224848631, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dab591e8-b136-4923-a683-e9971efb1b7c", "name": "3fa3ab7c-8f40-43ca-9727-3fbeca5f3e7b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "749e6bd0-8c6d-4d4f-be52-4afd163f1e24"}}}]}, {"uuid": "7d6f4ffd-ea62-44ad-940b-8f4102b7b3c6", "name": "load_p1rlv13189_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "268361f6-d5ac-4002-80a6-f56f3b33599c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dab591e8-b136-4923-a683-e9971efb1b7c"}}}}, {"uuid": "9a5cacf7-835a-49cf-acd7-b750f5c58c18", "name": "ab341bf9-86dc-4140-a854-37cb7399eacb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6702758059963014, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.7275069224848631, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1012a10a-56cf-4ac9-9911-897ba8019bfb", "name": "44268273-eb53-429a-8f44-2a6a4a41b061", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9a5cacf7-835a-49cf-acd7-b750f5c58c18"}}}]}, {"uuid": "bca953e6-f28c-436e-b66c-e5009a64a975", "name": "load_p1rlv13189_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "268361f6-d5ac-4002-80a6-f56f3b33599c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1012a10a-56cf-4ac9-9911-897ba8019bfb"}}}}, {"uuid": "395a2561-b788-4737-9b64-e078b6546749", "name": "e3699a39-4ba1-4a3c-bf6d-2e51ffb98753_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.667455481738122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8122169683202977, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "35ed602a-8684-4906-8cc5-28d4667ee3d0", "name": "fecd8dfc-615e-4e60-aa7f-ad1c564bd08e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "395a2561-b788-4737-9b64-e078b6546749"}}}]}, {"uuid": "a2a392ac-8ce7-4c1f-89fb-f905f3fcfbc4", "name": "load_p1rlv13190_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3dbc593c-3949-4fa4-8738-d92540dbf998"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "35ed602a-8684-4906-8cc5-28d4667ee3d0"}}}}, {"uuid": "fafb4c38-c350-42f5-b9bf-65b115e4be2a", "name": "75db384a-c407-4fe0-b583-acac860ef089_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.667455481738122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8122169683202977, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "edb4253e-fdd3-411f-990e-16e38c36492c", "name": "5fca91c1-9303-45b0-9c0a-6a572f1e48a2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fafb4c38-c350-42f5-b9bf-65b115e4be2a"}}}]}, {"uuid": "f2da2ffb-270d-4757-bbf1-9064b5ccbad5", "name": "load_p1rlv13190_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3dbc593c-3949-4fa4-8738-d92540dbf998"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "edb4253e-fdd3-411f-990e-16e38c36492c"}}}}, {"uuid": "15e0ada5-9a29-4e07-97ec-108affc305b4", "name": "500052cb-f666-4032-a2b2-bab8b21a3486_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.921717825926216, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5520868751081406, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "34f6ee7b-b630-4c41-93d1-81d672c2eb6a", "name": "d32ebdcd-458d-46eb-809d-09c340eac5ad", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "15e0ada5-9a29-4e07-97ec-108affc305b4"}}}]}, {"uuid": "6ef49a1a-54aa-4ea5-b8ec-a869524870c2", "name": "load_p1rlv13191_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f6d09e9-3592-4560-8626-0d7cb71ca56a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "34f6ee7b-b630-4c41-93d1-81d672c2eb6a"}}}}, {"uuid": "b91f19a4-1fa5-42e2-bc4c-63d94394b78b", "name": "293b3bea-f770-484c-af08-4aa060d931cf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.921717825926216, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5520868751081406, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "21b89c3c-7d8f-44f2-be4c-2729adb154b6", "name": "855faf25-9d72-460b-81f3-1f2d5b31611a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b91f19a4-1fa5-42e2-bc4c-63d94394b78b"}}}]}, {"uuid": "13399b76-ec3f-4106-959d-3a94f7c1ce5f", "name": "load_p1rlv13191_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f6d09e9-3592-4560-8626-0d7cb71ca56a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "21b89c3c-7d8f-44f2-be4c-2729adb154b6"}}}}, {"uuid": "9feed621-db52-4acd-aa85-7f7d9f2ec289", "name": "cdbb55a3-b472-4d02-925d-3f772077109b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5300176124233262, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6781680527999017, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "048611e6-65d1-4c10-a692-96661c2a8918", "name": "d17a7a92-cbd8-4c79-9bdc-cc7740946c9b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9feed621-db52-4acd-aa85-7f7d9f2ec289"}}}]}, {"uuid": "4f0ccd3a-8be6-405b-985a-749cf90427ca", "name": "load_p1rlv13194_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d5ba889-d8f7-44ca-86b2-40939fa95df2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "048611e6-65d1-4c10-a692-96661c2a8918"}}}}, {"uuid": "2475c74c-94c4-46d5-8d6d-bac499071094", "name": "8e9d3c6d-fe0b-4f56-bb2b-6ce8739d7903_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5300176124233262, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6781680527999017, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "adda3498-b470-40e0-ad6d-84898623c771", "name": "d70c74cf-2de6-4495-8cb0-9eb84d9b96d0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2475c74c-94c4-46d5-8d6d-bac499071094"}}}]}, {"uuid": "e20cfae8-25b8-4116-9fe0-d5f20ebe404a", "name": "load_p1rlv13194_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d5ba889-d8f7-44ca-86b2-40939fa95df2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "adda3498-b470-40e0-ad6d-84898623c771"}}}}, {"uuid": "bbf7c688-0003-4d2e-8ecd-7359df36e721", "name": "c3def5f5-ec1e-4744-82c5-7166a5e86bde_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5670847441713207, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5540004468841006, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4abf7b78-c528-4955-94e5-48b90677531d", "name": "7880990d-bbf5-4fb9-98dc-41446ae0eaa8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bbf7c688-0003-4d2e-8ecd-7359df36e721"}}}]}, {"uuid": "5edc1716-e850-46c9-a684-263e46e62c9f", "name": "load_p1rlv13195_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e3e10c6-6ce2-4efa-be50-80e8b9bffe29"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4abf7b78-c528-4955-94e5-48b90677531d"}}}}, {"uuid": "02148270-d3f4-4c59-a2db-180eaa5f6e7d", "name": "0ab68643-d170-4d11-9c01-c0b81c3e2af2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5670847441713207, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5540004468841006, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2c5372b0-f45f-4a43-85e2-dde672b97a62", "name": "d1c9efd6-80e1-43dc-8b93-a1edd8d4263f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "02148270-d3f4-4c59-a2db-180eaa5f6e7d"}}}]}, {"uuid": "490acbcf-dec4-4965-9313-3498325efe09", "name": "load_p1rlv13195_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e3e10c6-6ce2-4efa-be50-80e8b9bffe29"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2c5372b0-f45f-4a43-85e2-dde672b97a62"}}}}, {"uuid": "6ae648fb-d09e-4c41-87e0-ca3a8d0da424", "name": "43c5e241-13d0-45b1-bce1-197bff3fa4ed_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.565985425671141, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8139237791533422, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "16e574a4-551a-4860-bf7f-1b8f4617b7ab", "name": "2875abd9-9f4b-4fcc-a8c8-6c53d49e4ae6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6ae648fb-d09e-4c41-87e0-ca3a8d0da424"}}}]}, {"uuid": "44c680a2-9eeb-4116-b0d5-0e2bba96cec1", "name": "load_p1rlv13196_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27013147-3d8f-4d75-a7a7-24457dc6d62a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "16e574a4-551a-4860-bf7f-1b8f4617b7ab"}}}}, {"uuid": "68149fca-3636-4d63-9aaf-a9776af7b4e5", "name": "7b062a3e-0dc2-44f1-8468-4e827b78a170_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.565985425671141, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8139237791533422, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "39d7fb73-eecd-4c90-a1b8-eea91fa80906", "name": "e2a1874f-f68a-4327-92c9-7c5bd349cba2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "68149fca-3636-4d63-9aaf-a9776af7b4e5"}}}]}, {"uuid": "18e6f764-9dc2-401a-aca6-387a640cb498", "name": "load_p1rlv13196_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27013147-3d8f-4d75-a7a7-24457dc6d62a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "39d7fb73-eecd-4c90-a1b8-eea91fa80906"}}}}, {"uuid": "cd3bf1f7-178e-4e37-af1c-71ee3fda84e2", "name": "8676102d-bd6e-4b64-8139-35261d0b516a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.88875250566531, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3533612733571443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3cb4cecc-fd03-46ca-8a7a-11f6d3c25706", "name": "6f4eef1e-5b06-427a-84e7-3dff9c0dd9ce", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cd3bf1f7-178e-4e37-af1c-71ee3fda84e2"}}}]}, {"uuid": "86dc39cd-37d2-4751-b049-62efd6d1d044", "name": "load_p1rlv13197_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b077d0f-74ec-4a04-8eb8-cf02ad16077d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3cb4cecc-fd03-46ca-8a7a-11f6d3c25706"}}}}, {"uuid": "00470f98-ca1d-4fe8-9eed-62ae6a5acb98", "name": "d9e8a415-8eb6-413a-bf6d-0d82fe874249_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.88875250566531, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3533612733571443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2d6ec1b4-1f84-43d0-a8f9-f697149b8cd9", "name": "65b56eab-9f11-4f42-820b-a98de379bc18", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "00470f98-ca1d-4fe8-9eed-62ae6a5acb98"}}}]}, {"uuid": "4941ce80-fbd4-4920-9b61-4a7973328dd5", "name": "load_p1rlv13197_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b077d0f-74ec-4a04-8eb8-cf02ad16077d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2d6ec1b4-1f84-43d0-a8f9-f697149b8cd9"}}}}, {"uuid": "d2d312dd-e429-44ee-b1da-478fe98a0d04", "name": "6b12e10f-4c38-48df-8729-363a813877c5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5401800544546385, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5525745253976501, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0e2ff513-8470-4dd8-bb10-1303f457ef6d", "name": "a4a5ac02-22f4-4b08-aa51-dd56d2eb35b5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d2d312dd-e429-44ee-b1da-478fe98a0d04"}}}]}, {"uuid": "ab52a8d9-56d7-4505-96f6-43958c808cbb", "name": "load_p1rlv13199_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad7545fb-8a41-4ed7-a178-e90f19bfa9d5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0e2ff513-8470-4dd8-bb10-1303f457ef6d"}}}}, {"uuid": "f5108d12-4535-409d-89cf-f89b367b6bb8", "name": "0c23895e-b538-43eb-9188-29f3b222bf8a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5401800544546385, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5525745253976501, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4024c612-bd14-466c-99e8-09f9b24f32bb", "name": "c2842eae-ba25-4847-bfa8-2fc534e875b6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f5108d12-4535-409d-89cf-f89b367b6bb8"}}}]}, {"uuid": "680b353e-4b9e-4cfd-8563-474184c7c4a4", "name": "load_p1rlv13199_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad7545fb-8a41-4ed7-a178-e90f19bfa9d5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4024c612-bd14-466c-99e8-09f9b24f32bb"}}}}, {"uuid": "5836d2d8-73bf-4713-aa19-2ebdb75d814e", "name": "3aa35252-4a62-4093-a046-1f26b5cccc96_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4622944887503224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10483650830237357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f3830231-d432-4ea1-a877-c43e1eb23c26", "name": "4406571f-ea0c-40d5-a95f-1d6ff0358e22", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5836d2d8-73bf-4713-aa19-2ebdb75d814e"}}}]}, {"uuid": "0cdce4ca-4ae0-4ef2-ab2e-21943cabf260", "name": "load_p1rlv13200_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fed30a3f-12a5-4545-b5d5-5c13a131a256"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f3830231-d432-4ea1-a877-c43e1eb23c26"}}}}, {"uuid": "24e9efc8-e540-453e-9c06-acb8376f8c87", "name": "e00d3e41-118b-4b67-9282-585e3a1062a6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4622944887503224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10483650830237357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e3e004c0-59f7-4008-bfc3-b21a8a3c2ec1", "name": "e944d3f7-b958-4ad8-babc-f3b650222041", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "24e9efc8-e540-453e-9c06-acb8376f8c87"}}}]}, {"uuid": "5cbfb4b6-8fe8-4226-9c2b-6a740d74a7dc", "name": "load_p1rlv13200_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fed30a3f-12a5-4545-b5d5-5c13a131a256"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e3e004c0-59f7-4008-bfc3-b21a8a3c2ec1"}}}}, {"uuid": "bf2b6285-13cf-417c-9019-df8d6d921784", "name": "72893fec-4075-4f0c-8439-ec735f3c3781_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.195601026095605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4379463760124337, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0690c0af-36e8-4faf-9931-a3452f52186f", "name": "b34d8a4c-b257-436f-8c55-a9c836295b91", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bf2b6285-13cf-417c-9019-df8d6d921784"}}}]}, {"uuid": "3c26dedc-4fc5-4269-ac0d-51bb1fe00d43", "name": "load_p1rlv13201_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cdd7c49-e758-4009-8db5-d0b5748f919c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0690c0af-36e8-4faf-9931-a3452f52186f"}}}}, {"uuid": "0381ba9f-4f61-4e8b-8f3e-33df9c63f2be", "name": "9255e6bf-8dac-41ed-818f-a3af6456b1a5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.195601026095605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4379463760124337, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1bb6d719-9f60-4715-acf7-328790d4356c", "name": "9c0ddcdd-a56e-4be5-a7dd-f0299fc3231b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0381ba9f-4f61-4e8b-8f3e-33df9c63f2be"}}}]}, {"uuid": "95beee2e-b0cd-4efd-a08f-b5aa0d3b96a2", "name": "load_p1rlv13201_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cdd7c49-e758-4009-8db5-d0b5748f919c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1bb6d719-9f60-4715-acf7-328790d4356c"}}}}, {"uuid": "f03edf52-7271-4a3e-ae1f-53a895760067", "name": "acb7d454-6f87-41e9-9a36-d2c551b386b6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8140414184691503, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34693077623207685, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7fe60fff-7fd7-4d9d-9182-8c33ae3cc32f", "name": "dab218dc-48d1-42fd-97bc-69e46edfd8ee", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f03edf52-7271-4a3e-ae1f-53a895760067"}}}]}, {"uuid": "9702e0ce-9c9a-4469-a0a1-a78d4c62d7f2", "name": "load_p1rlv13316_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473b080b-1412-40dc-a452-09d43a462098"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7fe60fff-7fd7-4d9d-9182-8c33ae3cc32f"}}}}, {"uuid": "3d64967f-5c6c-4c44-baff-4cea9d9023d4", "name": "ee63e168-4c6b-458f-9279-3f5f3a415f27_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8140414184691503, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34693077623207685, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d71051fc-5760-4907-b6d4-890667fc0d5b", "name": "048ee0ab-8d53-47d7-b9ed-62a8e4068d7b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3d64967f-5c6c-4c44-baff-4cea9d9023d4"}}}]}, {"uuid": "b6dbfe6e-a255-4b3a-b58c-e03141eab622", "name": "load_p1rlv13316_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473b080b-1412-40dc-a452-09d43a462098"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d71051fc-5760-4907-b6d4-890667fc0d5b"}}}}, {"uuid": "dac1c5ce-10b4-4584-9591-5e05bef98c5d", "name": "937de26d-9b11-4d11-ab4a-279351ae6c89_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a0c87f0-5315-4a11-85e7-c6b554c99a2b", "name": "fcf85268-ac67-4816-9093-b27b458df88f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dac1c5ce-10b4-4584-9591-5e05bef98c5d"}}}]}, {"uuid": "edc77fc3-e069-4d18-96c9-61760d32f742", "name": "load_p1rlv13597_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "353889fb-da44-4cf8-ae0e-d20541f36d7e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0a0c87f0-5315-4a11-85e7-c6b554c99a2b"}}}}, {"uuid": "26e8b0dc-2ac3-4742-ac43-55c0bb67b561", "name": "e0a5dbc6-77a6-4835-998c-1543298e0f8f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d9e348bd-8fff-4da1-98f1-8a90ff9da829", "name": "7ac170e6-bc12-4fef-b7e3-5c414b03ece6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "26e8b0dc-2ac3-4742-ac43-55c0bb67b561"}}}]}, {"uuid": "1d33447a-cabc-4c04-8811-f06c7603e54e", "name": "load_p1rlv13597_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "353889fb-da44-4cf8-ae0e-d20541f36d7e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d9e348bd-8fff-4da1-98f1-8a90ff9da829"}}}}, {"uuid": "37c4d4ed-d4bc-46ee-b908-0a71a5aa6518", "name": "800bea90-02ed-4d86-a2d7-34d14bf5aad6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "041a363b-8459-4191-a6f5-4685aeb8936b", "name": "ecc00417-30b1-427f-a6f3-81ae9febefaf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "37c4d4ed-d4bc-46ee-b908-0a71a5aa6518"}}}]}, {"uuid": "6033b316-93cf-415e-841e-82f4e21dbc25", "name": "load_p1rlv13598_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59953c2f-244e-4bb8-ab24-b28d82b195e1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "041a363b-8459-4191-a6f5-4685aeb8936b"}}}}, {"uuid": "c7f4cc2e-d190-4b9b-82c7-99a025144f6e", "name": "3e28f879-bbd7-4454-b56a-0e32fb67f207_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4913cce6-590b-4348-900a-b797faf546fd", "name": "20331403-4b6e-4cf2-837a-2862b0536e98", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c7f4cc2e-d190-4b9b-82c7-99a025144f6e"}}}]}, {"uuid": "63dca524-7496-41cc-9c8c-adcfbbe727bc", "name": "load_p1rlv13598_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59953c2f-244e-4bb8-ab24-b28d82b195e1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4913cce6-590b-4348-900a-b797faf546fd"}}}}, {"uuid": "c88ab96a-c49c-422b-bfd3-498b6fc68c01", "name": "1e50911e-2f5c-4f91-8819-6bbb0a799416_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cb268438-07b7-4715-968d-4f6ab65bcc52", "name": "49bf7cd1-6dfb-4119-b3d1-0f9ba6162d72", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c88ab96a-c49c-422b-bfd3-498b6fc68c01"}}}]}, {"uuid": "9be21e16-3c8d-4128-ab14-c6911cd8c684", "name": "load_p1rlv13599_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2a60818-4310-4100-9aa8-35ef37aa5f40"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cb268438-07b7-4715-968d-4f6ab65bcc52"}}}}, {"uuid": "bfcd7e85-efbc-4cfa-b47b-9ae669d6966c", "name": "bc0bb68d-ed14-4e89-9996-9bb3483c92c5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5e70eb0d-153f-4fb3-a538-2b0c4a1dc9fc", "name": "c3e6a5e6-3a47-4917-9dba-1bb6074677eb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bfcd7e85-efbc-4cfa-b47b-9ae669d6966c"}}}]}, {"uuid": "bdc775ec-84d1-4a2c-bb98-c1e19e71da3c", "name": "load_p1rlv13599_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2a60818-4310-4100-9aa8-35ef37aa5f40"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5e70eb0d-153f-4fb3-a538-2b0c4a1dc9fc"}}}}, {"uuid": "86a1a85e-300d-4da9-84ff-1fe5a2e5461f", "name": "c7009d2b-05c2-440b-b854-afa1d3a88ecb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.940151571607843, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7360323556900852, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3b91ff6a-d898-4df2-b1d2-53ce9e03bb81", "name": "348b7989-2c3f-46ef-b687-739cb14395a3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "86a1a85e-300d-4da9-84ff-1fe5a2e5461f"}}}]}, {"uuid": "e17443e8-f800-420d-803b-6bd11600508f", "name": "load_p1rlv13600_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59ab6d81-a91c-4350-8f94-abe02e3e1555"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3b91ff6a-d898-4df2-b1d2-53ce9e03bb81"}}}}, {"uuid": "34d0ec8c-f568-4d5b-81ed-0a449f709d4e", "name": "61bad4c4-8759-486c-8089-62cce9f8522a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.940151571607843, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7360323556900852, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "928b9698-5fd4-4dcb-b44f-e91ba1da74bc", "name": "e1242757-0cfe-4113-96b9-c8744221d741", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "34d0ec8c-f568-4d5b-81ed-0a449f709d4e"}}}]}, {"uuid": "7ecbba76-6fc2-4902-8f7e-ed8a8223ba90", "name": "load_p1rlv13600_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59ab6d81-a91c-4350-8f94-abe02e3e1555"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "928b9698-5fd4-4dcb-b44f-e91ba1da74bc"}}}}, {"uuid": "95ebc42e-d8ed-4efc-9e8d-d01fdf170ded", "name": "0ceedc81-bfb3-4288-961c-0e49525bf1d9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.872515319591797, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7328111219910317, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bf6f99c3-a9c4-4e4b-820c-a2e12bfe4966", "name": "f3195a99-0a13-4b39-8ab3-dc1c65446089", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "95ebc42e-d8ed-4efc-9e8d-d01fdf170ded"}}}]}, {"uuid": "fb643b41-122e-4bf0-b101-29d55e2bc232", "name": "load_p1rlv13601_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91953a27-bbc7-494a-bec2-a12b4c0f6af6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bf6f99c3-a9c4-4e4b-820c-a2e12bfe4966"}}}}, {"uuid": "07ad6e5f-b4ba-43fc-8288-53ecc9792bdd", "name": "b9747aa8-2e9e-4db4-94d7-2b04e560536a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.872515319591797, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7328111219910317, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "51667fa2-0da1-4cca-ad8a-6a60cfc43683", "name": "4cef8fd1-a3ff-4f2b-abb8-d9bcf4da4242", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "07ad6e5f-b4ba-43fc-8288-53ecc9792bdd"}}}]}, {"uuid": "b5b4f2e8-4da2-4bb5-9f06-43efb167b2a9", "name": "load_p1rlv13601_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91953a27-bbc7-494a-bec2-a12b4c0f6af6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "51667fa2-0da1-4cca-ad8a-6a60cfc43683"}}}}, {"uuid": "ea1ce7af-6d0a-423b-bc32-74905847c262", "name": "b61e5da4-890c-407d-a6f0-8fd358dda581_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.308477864741614, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307751830484037, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a45011c6-1d24-462b-99f0-9537120e1f35", "name": "614283b0-7844-438c-9863-4124f7dfc777", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ea1ce7af-6d0a-423b-bc32-74905847c262"}}}]}, {"uuid": "5402fdc5-a823-41d7-9db4-622ed2bf74bf", "name": "load_p1rlv13604_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9b83bdf-b564-4997-bfc7-1be2f2e58199"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a45011c6-1d24-462b-99f0-9537120e1f35"}}}}, {"uuid": "7378b82f-38ce-4c28-a550-c37b78d7b46c", "name": "86fa24a9-15a6-4d02-b561-bb5e1e8eba63_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.308477864741614, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307751830484037, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "13368055-1611-4a68-a552-3ecc6be93c50", "name": "58a60a73-ac22-4a59-9aa9-d024c3804259", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7378b82f-38ce-4c28-a550-c37b78d7b46c"}}}]}, {"uuid": "6c4e0cf3-fbb2-48bd-a319-e909a6b7afdc", "name": "load_p1rlv13604_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9b83bdf-b564-4997-bfc7-1be2f2e58199"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "13368055-1611-4a68-a552-3ecc6be93c50"}}}}, {"uuid": "96374ea5-49ab-4bb4-9b0f-e042b6f86caf", "name": "d2525f13-738e-4d5c-8557-092bc2a7aea9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0263288002917053, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.546221099657035, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6ac379df-438b-4c9a-9cee-907cb9ac2b96", "name": "d690a139-4ae2-45e1-9f14-79bf3d186cd3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "96374ea5-49ab-4bb4-9b0f-e042b6f86caf"}}}]}, {"uuid": "aa4e9307-1124-451d-bab1-24bd64df40db", "name": "load_p1rlv13605_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c39dc6f1-08b5-4bc1-a6ae-be0076af56aa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6ac379df-438b-4c9a-9cee-907cb9ac2b96"}}}}, {"uuid": "30529f9d-37bc-4c22-9856-0356ce450b19", "name": "2d6e29aa-c304-4568-a7ce-9e4ceaebc081_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0263288002917053, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.546221099657035, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "232736c1-342b-4abb-815a-85de36131904", "name": "cbb570ad-e05a-49e4-af04-6f5c1e6881c1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "30529f9d-37bc-4c22-9856-0356ce450b19"}}}]}, {"uuid": "88f60a05-1c81-46dc-b19b-d233db420470", "name": "load_p1rlv13605_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c39dc6f1-08b5-4bc1-a6ae-be0076af56aa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "232736c1-342b-4abb-815a-85de36131904"}}}}, {"uuid": "263e7d44-927e-42de-9b33-bc043e89c1c4", "name": "9a2d242b-b087-4c69-8f6d-278d9910f3d0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3058115791316, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6614039959360709, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3da29d94-7b41-43c1-93a6-dfa9f53858d7", "name": "9aa3ae61-c7b5-47b7-aa9d-5c8c80616f35", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "263e7d44-927e-42de-9b33-bc043e89c1c4"}}}]}, {"uuid": "513733d5-ddd6-4f64-84e2-3b9839127ace", "name": "load_p1rlv13606_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29838633-5c95-4b73-8227-cfa7f4aedc32"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3da29d94-7b41-43c1-93a6-dfa9f53858d7"}}}}, {"uuid": "c3508a5a-022c-43f9-9b4e-2ae2096aaa94", "name": "2aab3bd4-5cf8-4bcd-8736-1ba0c8b52714_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3058115791316, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6614039959360709, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "db7406f9-285f-4b88-a7df-591a5a6e057e", "name": "7e72a4ff-304d-46fd-b528-4db1ec619d00", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c3508a5a-022c-43f9-9b4e-2ae2096aaa94"}}}]}, {"uuid": "c3367ac3-ed0f-4f82-9322-d35372941dad", "name": "load_p1rlv13606_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29838633-5c95-4b73-8227-cfa7f4aedc32"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "db7406f9-285f-4b88-a7df-591a5a6e057e"}}}}, {"uuid": "d7118512-4d9f-4803-a23a-381c995f83d5", "name": "8f5f7a71-ef92-4554-b3f5-ec6859e30f41_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a684586-7b36-4a30-97ad-40077a5b1a2a", "name": "8bd626f0-1c1f-4b3d-97d1-a826eba24e2a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d7118512-4d9f-4803-a23a-381c995f83d5"}}}]}, {"uuid": "e224fb14-299d-47f6-9ef1-eda559eb944e", "name": "load_p1rlv13608_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5e8caf4-4d81-4bbd-98df-6622c5ad0563"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a684586-7b36-4a30-97ad-40077a5b1a2a"}}}}, {"uuid": "28630b53-5791-4151-9f80-b012654e5bbe", "name": "22d967d4-e19a-4c1e-8516-2630a06cb526_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "17a1254d-30de-4ff2-9c67-8f9c56bcdcdb", "name": "b8b4fca4-7ce8-4b31-8cea-14e2ee0c4126", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "28630b53-5791-4151-9f80-b012654e5bbe"}}}]}, {"uuid": "9e615355-12ee-4e44-8d83-55496ef1fcf3", "name": "load_p1rlv13608_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5e8caf4-4d81-4bbd-98df-6622c5ad0563"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "17a1254d-30de-4ff2-9c67-8f9c56bcdcdb"}}}}, {"uuid": "1feccc53-8a55-4dc6-9f14-4cf6e7aeebdc", "name": "8e9ec97c-4e8e-477f-ae8c-95e2d6519669_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5204227867871802, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7134940441409878, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "efc5b363-454a-4a41-938c-d9814f2c1f71", "name": "56b8d8b3-7160-498a-adf8-e9d5489fc83e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1feccc53-8a55-4dc6-9f14-4cf6e7aeebdc"}}}]}, {"uuid": "db709395-c523-49cd-bc4c-951458b96c38", "name": "load_p1rlv13610_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17d92377-b4f1-4194-89cd-130bddb9b77c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "efc5b363-454a-4a41-938c-d9814f2c1f71"}}}}, {"uuid": "3d4a40ad-cf2f-48cc-91b8-c510fcfd720a", "name": "2f6e39fc-02dc-4ced-b0c9-d2e034212c8b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5204227867871802, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7134940441409878, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "22cf121f-0a5e-4231-a163-421c123a468b", "name": "ac3812fd-6712-48ea-a30a-3a72ae609341", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3d4a40ad-cf2f-48cc-91b8-c510fcfd720a"}}}]}, {"uuid": "30ca95f8-c26e-4560-b35e-048e5962d8eb", "name": "load_p1rlv13610_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17d92377-b4f1-4194-89cd-130bddb9b77c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "22cf121f-0a5e-4231-a163-421c123a468b"}}}}, {"uuid": "a9e4bce4-e5ea-4dbe-9c8b-0996a5871289", "name": "b0ee7b25-6a5f-4828-bb53-791e41cee671_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2489699911360574, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6200743429841856, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ace91704-0ee2-4020-8008-431ae1f26054", "name": "eebf7c81-db20-425a-8370-c45b1c52bb94", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a9e4bce4-e5ea-4dbe-9c8b-0996a5871289"}}}]}, {"uuid": "2f7690c2-b063-4a26-95de-fd6e37f8f5e8", "name": "load_p1rlv13611_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "630b2a63-622f-4f78-8390-77c69ba7e393"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ace91704-0ee2-4020-8008-431ae1f26054"}}}}, {"uuid": "38d953b6-3f7b-4e8e-be9a-ae293ecbf7d8", "name": "42816fc3-6691-4291-a26a-fc09ab7e3bc0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2489699911360574, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6200743429841856, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5dd03872-be94-4cdd-a533-e296b0ac4845", "name": "594456f4-453a-4fc6-af35-02d1f8ae5882", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "38d953b6-3f7b-4e8e-be9a-ae293ecbf7d8"}}}]}, {"uuid": "911a5c75-08be-456c-973b-9a4c69d19096", "name": "load_p1rlv13611_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "630b2a63-622f-4f78-8390-77c69ba7e393"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5dd03872-be94-4cdd-a533-e296b0ac4845"}}}}, {"uuid": "ceabb95c-76b6-47da-a2a5-4e08546fcc2b", "name": "025048b4-8552-4dc2-9bb0-12431180acd8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0788570276665777, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5949433355568994, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e582b791-1f79-4fe0-9652-895edb6344c8", "name": "d53d11c2-17ce-4f3c-a9fd-6078dad4bbd9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ceabb95c-76b6-47da-a2a5-4e08546fcc2b"}}}]}, {"uuid": "61c13545-2cec-4589-b92e-12a351832386", "name": "load_p1rlv13612_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6eda3e97-a618-41ab-ae55-ba67f6bb0234"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e582b791-1f79-4fe0-9652-895edb6344c8"}}}}, {"uuid": "38891ee9-4cab-4112-95d0-c271e8712dac", "name": "2a6196bf-11e5-4c12-ae76-cd971eb48e56_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0788570276665777, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5949433355568994, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2c0dfc31-f7c5-448a-b043-29789cc89020", "name": "7df2e922-0b73-4fa6-9815-4813fb83d211", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "38891ee9-4cab-4112-95d0-c271e8712dac"}}}]}, {"uuid": "950cc650-04a5-4d24-bcbe-53ff2c5a8a71", "name": "load_p1rlv13612_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6eda3e97-a618-41ab-ae55-ba67f6bb0234"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2c0dfc31-f7c5-448a-b043-29789cc89020"}}}}, {"uuid": "615db8c4-a370-422f-8b4d-781af51be9d4", "name": "ef027f39-0c3c-4bc3-8c3f-55acd3dc42f9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4038244377730775, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.30842299757959857, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "577b1b4d-48de-488a-b861-edbf0baf30ba", "name": "05b1a662-a415-49ce-a317-1d02d95e6738", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "615db8c4-a370-422f-8b4d-781af51be9d4"}}}]}, {"uuid": "dd4d943d-5659-4a56-b23f-4c946dda2361", "name": "load_p1rlv13613_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "216537dd-ea7b-461c-b821-99491c41b7f0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "577b1b4d-48de-488a-b861-edbf0baf30ba"}}}}, {"uuid": "5dc94bd8-c89f-4a2d-89cb-5ec7d3fd4fd5", "name": "a779b030-b0ef-4643-9c38-2a0b46685b34_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4038244377730775, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.30842299757959857, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "099b682b-fba1-4215-bfcf-8fc8cec8d482", "name": "858472de-7dc6-4d68-b184-da80b2f6fe29", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5dc94bd8-c89f-4a2d-89cb-5ec7d3fd4fd5"}}}]}, {"uuid": "3c640205-45c4-40ae-9e42-96ac27b81452", "name": "load_p1rlv13613_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "216537dd-ea7b-461c-b821-99491c41b7f0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "099b682b-fba1-4215-bfcf-8fc8cec8d482"}}}}, {"uuid": "c401073b-65fd-4fcc-a753-63093a15d2a7", "name": "aa64dd19-278b-4f71-b580-5e4a6d3dd375_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8b433e2b-9be7-4845-9f80-726834f5e0a3", "name": "80429f8b-4518-49fa-821e-18823aba8c08", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c401073b-65fd-4fcc-a753-63093a15d2a7"}}}]}, {"uuid": "513e3258-3983-4da3-bcc3-6daa810f2225", "name": "load_p1rlv13614_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3de8b994-01ba-4eae-b9cf-7fb174d32355"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8b433e2b-9be7-4845-9f80-726834f5e0a3"}}}}, {"uuid": "c8bf0b27-96cd-421f-8407-d565d173abd1", "name": "da73a03b-3f48-4f38-9384-ac4f10889abd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "650cf6ba-fe0c-4878-b263-0128aa0144d0", "name": "5a5810e9-1f98-404f-a07c-e1219374cffa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c8bf0b27-96cd-421f-8407-d565d173abd1"}}}]}, {"uuid": "7406de4a-2f49-4d2a-8c76-cafbe9ba85c2", "name": "load_p1rlv13614_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3de8b994-01ba-4eae-b9cf-7fb174d32355"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "650cf6ba-fe0c-4878-b263-0128aa0144d0"}}}}, {"uuid": "c661fa66-2f5a-43d5-99bf-3ff16796aaed", "name": "c0e4c6b3-3279-479f-ac5d-8dc382c17966_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5937162117629007, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7166618655640316, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7153f498-dbb9-489e-b8e7-8f16d884d4c2", "name": "e9e9f350-68d2-45c2-ba4d-47d5bba6f8e0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c661fa66-2f5a-43d5-99bf-3ff16796aaed"}}}]}, {"uuid": "f9a7de0e-1624-4e03-a4d4-0bf885f4db72", "name": "load_p1rlv13616_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "850d5b69-14cf-4a18-8cb0-4f1b3033b0aa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7153f498-dbb9-489e-b8e7-8f16d884d4c2"}}}}, {"uuid": "84568431-202f-46d3-a1a7-6cf36056966d", "name": "4c3f9928-dd45-4c08-8226-a9af82946f53_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5937162117629007, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7166618655640316, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4ff9e464-1d53-4124-aa0c-1d94088c75da", "name": "f60b7063-cd28-448b-8075-e90671f50e66", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "84568431-202f-46d3-a1a7-6cf36056966d"}}}]}, {"uuid": "63f4474e-0953-4d5e-b2d1-64cf24a77cc6", "name": "load_p1rlv13616_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "850d5b69-14cf-4a18-8cb0-4f1b3033b0aa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4ff9e464-1d53-4124-aa0c-1d94088c75da"}}}}, {"uuid": "0243729f-a4f3-4b56-a9ab-92767d1d70a5", "name": "6358a027-9c78-4156-8d36-a3bb6ae9dea7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.32403643380503, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6293121819683343, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ec564e10-1096-40d1-aabf-086dcfce9ad1", "name": "bfbd1fab-efe8-4742-9ec7-e067bf5b8101", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0243729f-a4f3-4b56-a9ab-92767d1d70a5"}}}]}, {"uuid": "9d936c16-a4ef-41d3-a02b-81a91da4ab6f", "name": "load_p1rlv13618_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f823a90c-effd-489c-9e0a-c110ccb7b9e8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ec564e10-1096-40d1-aabf-086dcfce9ad1"}}}}, {"uuid": "982da60c-87b4-4c34-ab26-f5fc1800475c", "name": "7d175011-18a2-48ee-9860-86faf3a84ead_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.32403643380503, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6293121819683343, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a60f819f-3886-44bb-b377-d01b1a10dbb7", "name": "b5976cb3-6e35-4410-b95d-deb0d34c43e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "982da60c-87b4-4c34-ab26-f5fc1800475c"}}}]}, {"uuid": "ecfe68a2-0142-4266-a254-a2845e55b700", "name": "load_p1rlv13618_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f823a90c-effd-489c-9e0a-c110ccb7b9e8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a60f819f-3886-44bb-b377-d01b1a10dbb7"}}}}, {"uuid": "1a69abb9-b58e-4d90-82f6-eb37166b9bd1", "name": "8fb1d5ac-e728-4989-a7bc-cee6ea816c78_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f3a8970e-e470-4043-80aa-fb20167e1294", "name": "5abaf938-70c7-4202-81f3-18640982dbd3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1a69abb9-b58e-4d90-82f6-eb37166b9bd1"}}}]}, {"uuid": "81bfac05-e086-4de0-83c9-c6e2a05cc9a7", "name": "load_p1rlv13619_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f693a1d2-5499-4810-9458-f205eda265fa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f3a8970e-e470-4043-80aa-fb20167e1294"}}}}, {"uuid": "26cc3290-18c5-492c-a8b9-e11d1ac7ae2b", "name": "d10fdde6-9faf-436f-8462-ad79941e50fd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50973f29-fe75-4d0e-9ddb-b975772b2ce8", "name": "afdb77a0-c05b-4936-8e17-42daaec74c50", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "26cc3290-18c5-492c-a8b9-e11d1ac7ae2b"}}}]}, {"uuid": "9e9747fe-1fab-4906-80cc-2990dc64a58d", "name": "load_p1rlv13619_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f693a1d2-5499-4810-9458-f205eda265fa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50973f29-fe75-4d0e-9ddb-b975772b2ce8"}}}}, {"uuid": "540b6425-7b6a-418a-9407-b741ccfbc1f0", "name": "331275d4-11df-4025-bd14-639b10811382_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3711169311548215, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.698133467399761, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dd8c0a0d-94a1-4a22-8ae4-7f99f1e72767", "name": "cba0580c-e34b-4136-934a-1954c8bef28e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "540b6425-7b6a-418a-9407-b741ccfbc1f0"}}}]}, {"uuid": "cd00aa99-b5c4-414d-8e55-6ec7ae7ed2cf", "name": "load_p1rlv13622_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4540b2cb-ee21-4515-a7ca-fbca371f060d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dd8c0a0d-94a1-4a22-8ae4-7f99f1e72767"}}}}, {"uuid": "b69fd5c7-dfe1-4a99-bafc-eeaa6547cdde", "name": "b932ded9-91ac-49b2-9cf7-60be0a24b0de_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3711169311548215, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.698133467399761, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b511ff2f-d16a-4da3-8c26-026b36bcf320", "name": "81520e07-1b5e-47f8-831d-fbc974227fc0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b69fd5c7-dfe1-4a99-bafc-eeaa6547cdde"}}}]}, {"uuid": "be39051c-160a-4255-82db-c4f94178fc78", "name": "load_p1rlv13622_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4540b2cb-ee21-4515-a7ca-fbca371f060d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b511ff2f-d16a-4da3-8c26-026b36bcf320"}}}}, {"uuid": "16db1fde-6327-40dc-b52c-9f4a9422dcab", "name": "b644319d-53f3-449a-8718-b090f40475ed_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6a2b4aa1-0e89-41f0-b2ee-237b8b4595cb", "name": "3194b37e-7435-4ed6-af61-d734630c7a8b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "16db1fde-6327-40dc-b52c-9f4a9422dcab"}}}]}, {"uuid": "823d3c38-d418-44a7-b3e7-990cef254e23", "name": "load_p1rlv13623_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80f60ab3-722f-4765-8b91-4fd0196171d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6a2b4aa1-0e89-41f0-b2ee-237b8b4595cb"}}}}, {"uuid": "6abe6328-7df4-44da-be3e-ba9d24e13cf2", "name": "5663592a-6245-44f0-8eec-b827b8056d8e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "386b9a03-f06a-44a2-8c0a-a07514b3e02c", "name": "efd73571-4bdf-4f76-8caa-8ca5bc2e86ce", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6abe6328-7df4-44da-be3e-ba9d24e13cf2"}}}]}, {"uuid": "a548b0cf-d329-424c-9939-c106e24fd913", "name": "load_p1rlv13623_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80f60ab3-722f-4765-8b91-4fd0196171d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "386b9a03-f06a-44a2-8c0a-a07514b3e02c"}}}}, {"uuid": "6353637a-3b3c-4a60-98ca-da3849ffab62", "name": "83606068-7e13-44f5-bd59-8eb99d849b7e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.611133182200907, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.07668264048246332, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5e111da4-7213-4700-aef8-69237ad31af7", "name": "55b70704-76f8-4604-abe8-e6358eb78676", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6353637a-3b3c-4a60-98ca-da3849ffab62"}}}]}, {"uuid": "87bf233e-57f9-4173-b00a-ad70cdf98074", "name": "load_p1rlv13624_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a5746d1-24a6-4ae4-b5dc-cef23b56660d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5e111da4-7213-4700-aef8-69237ad31af7"}}}}, {"uuid": "e7d644a0-c392-4633-988e-6be09deff0c3", "name": "035df44e-9561-422c-998f-a75dbe9ae4d4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.611133182200907, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.07668264048246332, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dd42cc15-e607-43c0-abb3-28e853c03221", "name": "fd2bc551-42c3-4ced-98c1-ba15d124bc6f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e7d644a0-c392-4633-988e-6be09deff0c3"}}}]}, {"uuid": "32fa6b51-eaaf-436a-bf91-636c328ee365", "name": "load_p1rlv13624_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a5746d1-24a6-4ae4-b5dc-cef23b56660d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dd42cc15-e607-43c0-abb3-28e853c03221"}}}}, {"uuid": "de0e49fe-3bdc-4a7d-b7d7-8338ab3dd376", "name": "777e7565-5332-4b34-962b-6a3114ca9330_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "900c9dcb-6b50-42ef-b05e-f4269e808dc3", "name": "ff4eb721-cb89-4c0e-8201-228b68fcbabe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "de0e49fe-3bdc-4a7d-b7d7-8338ab3dd376"}}}]}, {"uuid": "2706875b-9294-4ba4-bf0e-031c0118dbcc", "name": "load_p1rlv13625_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c667408-52a0-4258-8e93-557c94520a1e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "900c9dcb-6b50-42ef-b05e-f4269e808dc3"}}}}, {"uuid": "3ca686af-a312-424b-ad0a-a2857bea5608", "name": "da0f3f06-1012-4b11-b775-12810257b6b1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dbf022ae-cc92-42fb-80a6-57b5f4af35c9", "name": "e78818ab-c2d2-45d7-8e49-4178d541aa87", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3ca686af-a312-424b-ad0a-a2857bea5608"}}}]}, {"uuid": "3f8f8afb-ed05-41b4-b003-9dbd2533152e", "name": "load_p1rlv13625_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c667408-52a0-4258-8e93-557c94520a1e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dbf022ae-cc92-42fb-80a6-57b5f4af35c9"}}}}, {"uuid": "b5b8ebb5-3bad-4a3e-9274-6b3fe9628924", "name": "0d3c68fa-98b9-4457-9623-b2ddbef6bad9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2167250892906645, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5534364726692191, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "495030ab-3b27-4d33-b025-282b4b044338", "name": "2b498706-f03c-4f51-be0e-276bb22b8961", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5b8ebb5-3bad-4a3e-9274-6b3fe9628924"}}}]}, {"uuid": "56acabce-8878-49c1-b94c-af9220f4e454", "name": "load_p1rlv13626_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aeea20e0-9908-4f28-aa5d-068244e3861b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "495030ab-3b27-4d33-b025-282b4b044338"}}}}, {"uuid": "60e32a94-a8bc-42dd-8a92-eba24c87b680", "name": "b56423f4-655b-404a-9ed5-c661669886fd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2167250892906645, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5534364726692191, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1d65980a-33fe-4dfd-9088-9855d7e3a557", "name": "6243df8a-9e5d-47cb-b112-436fe69e32bd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "60e32a94-a8bc-42dd-8a92-eba24c87b680"}}}]}, {"uuid": "94ea13bc-304f-49d4-84d0-97ddf66b1fba", "name": "load_p1rlv13626_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aeea20e0-9908-4f28-aa5d-068244e3861b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1d65980a-33fe-4dfd-9088-9855d7e3a557"}}}}, {"uuid": "2ebe26fa-10b8-4996-a592-cf2d510877fc", "name": "fd6b2f83-f55c-4178-84d4-25f825f42afc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "29d57d91-dfb5-45cd-8116-2ed75b39201d", "name": "b9a16346-3061-4545-8663-f33e340b22b3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2ebe26fa-10b8-4996-a592-cf2d510877fc"}}}]}, {"uuid": "a9f67b6f-8541-4045-be0d-ac8ec292b43e", "name": "load_p1rlv13627_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bd69c55-2141-4c8e-becf-efa4bff8a63e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "29d57d91-dfb5-45cd-8116-2ed75b39201d"}}}}, {"uuid": "d390e1cb-6ad3-4c4e-8727-81af1319dbf9", "name": "e001b741-a080-4706-be40-76b9d706fd05_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aaccb708-0a7f-4541-9e29-2794fd6b3222", "name": "689efcce-d483-476d-8917-ae96f946d395", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d390e1cb-6ad3-4c4e-8727-81af1319dbf9"}}}]}, {"uuid": "1fe6206e-10f8-4593-a6d9-66b3a1e11005", "name": "load_p1rlv13627_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bd69c55-2141-4c8e-becf-efa4bff8a63e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aaccb708-0a7f-4541-9e29-2794fd6b3222"}}}}, {"uuid": "5502d664-87dc-4e88-928a-98ea7b6e2f1c", "name": "c876f41e-35b4-4931-9d0b-d9c056f9e7cf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6027984746974515, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12293402966163972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "83b5da43-aa46-4ca2-b714-e3e8d4d9aaa9", "name": "2d19e5a5-a6ec-41e1-82d1-d8affbe0489e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5502d664-87dc-4e88-928a-98ea7b6e2f1c"}}}]}, {"uuid": "f69095ba-372d-4810-8411-694971f43d18", "name": "load_p1rlv13628_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e47df44a-79f1-423b-a295-c9c354795895"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "83b5da43-aa46-4ca2-b714-e3e8d4d9aaa9"}}}}, {"uuid": "03010734-757c-40c6-8d5b-a9ba3e866412", "name": "c2fbd6ce-63a8-45aa-9508-6fc3cd17844f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6027984746974515, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12293402966163972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "28f34706-c5c5-47c0-8346-6aa590cb993d", "name": "f1053a09-9888-4e41-9153-fdb1d0b05c4b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "03010734-757c-40c6-8d5b-a9ba3e866412"}}}]}, {"uuid": "79aedce6-a8bc-4f93-b31b-189b72b22de8", "name": "load_p1rlv13628_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e47df44a-79f1-423b-a295-c9c354795895"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "28f34706-c5c5-47c0-8346-6aa590cb993d"}}}}, {"uuid": "00ece0df-1a03-4625-9c72-a0ca6a712f83", "name": "4e76d46b-b0e8-436f-9961-83e68ced5a03_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b240055e-61a7-4a40-8728-b15c9c4e3528", "name": "6954db8d-9915-4086-89b0-dd442cd5b3cb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "00ece0df-1a03-4625-9c72-a0ca6a712f83"}}}]}, {"uuid": "56bffc71-20a4-4d90-8fff-3853b9736046", "name": "load_p1rlv13629_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b4358536-b06f-486d-b336-3a8576b428d0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b240055e-61a7-4a40-8728-b15c9c4e3528"}}}}, {"uuid": "b5346d4f-4346-47c1-ad51-489a5fc3e057", "name": "ee48d810-87be-476c-b6e6-fde84b05eff7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4a16f94c-68e7-4d9b-a619-fb3c0c6948e1", "name": "a7574a04-fc39-4357-9ec9-540175bf69c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5346d4f-4346-47c1-ad51-489a5fc3e057"}}}]}, {"uuid": "d512e023-534b-4887-8712-d2b367fd903e", "name": "load_p1rlv13629_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b4358536-b06f-486d-b336-3a8576b428d0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4a16f94c-68e7-4d9b-a619-fb3c0c6948e1"}}}}, {"uuid": "db5ab1aa-2d9c-4125-94ab-3823975c45a3", "name": "44d7417b-8f31-4b33-a119-6accec609369_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.501244965400895, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7307193315393806, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d7b6bd43-b473-493b-bf4f-e32b4826ed05", "name": "cee0d6e8-87e3-4fd9-b102-fbbf8d850eb5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "db5ab1aa-2d9c-4125-94ab-3823975c45a3"}}}]}, {"uuid": "2af4f9b5-566b-464a-89b4-4f17c9947451", "name": "load_p1rlv13630_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f474e4ba-6300-4014-afe9-c245e08cf3c5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d7b6bd43-b473-493b-bf4f-e32b4826ed05"}}}}, {"uuid": "699807f1-fae9-44bc-88b0-f349cb4bed56", "name": "221e650d-7f9e-4569-b6d8-d9725b7f3b9d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.501244965400895, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7307193315393806, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "19f39d00-78bc-4894-a883-664fbe549f75", "name": "1bbe9954-28bc-42a3-9d62-ef25f2d9ce00", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "699807f1-fae9-44bc-88b0-f349cb4bed56"}}}]}, {"uuid": "e8373eda-07bd-4a9d-acc2-aa85eef3e840", "name": "load_p1rlv13630_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f474e4ba-6300-4014-afe9-c245e08cf3c5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "19f39d00-78bc-4894-a883-664fbe549f75"}}}}, {"uuid": "e3c35c21-d745-4909-889f-6bff9dea666a", "name": "8996a840-c56b-4244-a5bd-a936ab7e4f43_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7837050665512109, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.44874911637056014, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5ca7329c-2183-473b-95a9-77f2be94a3ca", "name": "0944f457-4c1a-46bc-b7c0-8ca6b1c791ce", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e3c35c21-d745-4909-889f-6bff9dea666a"}}}]}, {"uuid": "0a898f62-ea5c-418a-acc7-02c3c134dc37", "name": "load_p1rlv13631_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6015a810-79da-480f-b1a1-fd6a4abdba37"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5ca7329c-2183-473b-95a9-77f2be94a3ca"}}}}, {"uuid": "68c8d2e9-bf41-4d52-b183-24dae14b5724", "name": "248fdd00-1485-49b2-9fa5-142adc189657_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7837050665512109, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.44874911637056014, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b92698dc-2935-4f96-a813-b16d1e060ed2", "name": "1c437de2-b58b-4c30-af12-93c0d6925bcd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "68c8d2e9-bf41-4d52-b183-24dae14b5724"}}}]}, {"uuid": "91760696-f2be-4ed0-8a50-98d918418a84", "name": "load_p1rlv13631_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6015a810-79da-480f-b1a1-fd6a4abdba37"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b92698dc-2935-4f96-a813-b16d1e060ed2"}}}}, {"uuid": "625c002a-2b35-4e06-b117-f555d3def42e", "name": "05f7d4e7-22f5-4b84-ab66-ce7cc8d7b3fd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.008167500419157, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.871384812064858, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aae35308-2937-4f39-993b-ca2d5432f45b", "name": "0a7ea9ae-5600-43f7-aa3d-735141c55119", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "625c002a-2b35-4e06-b117-f555d3def42e"}}}]}, {"uuid": "d4468576-026b-47a1-ae83-e2a50b6701c7", "name": "load_p1rlv13632_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b712121-d0c2-488a-9224-bea72928796f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aae35308-2937-4f39-993b-ca2d5432f45b"}}}}, {"uuid": "85454153-f482-43f0-9863-54d33d19ad67", "name": "806f51fe-a83c-42ca-9771-481c667cb9fd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.008167500419157, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.871384812064858, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c5fb0cff-fe68-4ed9-b59f-4c1190ab0bf5", "name": "c5b13880-b54d-4f04-99cb-1632c874ae4a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "85454153-f482-43f0-9863-54d33d19ad67"}}}]}, {"uuid": "d2cb09f8-4845-4eb7-952d-96a7ea7bd35b", "name": "load_p1rlv13632_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b712121-d0c2-488a-9224-bea72928796f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c5fb0cff-fe68-4ed9-b59f-4c1190ab0bf5"}}}}, {"uuid": "4c650d9a-e789-4024-b747-a4f9b23a6fcb", "name": "c444ea98-6fdd-40da-bcdb-076334c4a3c8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4201171911594663, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7913664471178815, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7ddcbf16-7aee-400a-867b-1625d9b2aae7", "name": "e682a673-e790-4b62-937b-bbd1709020ea", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4c650d9a-e789-4024-b747-a4f9b23a6fcb"}}}]}, {"uuid": "a24f56d6-69d9-4acf-adf0-a7c175597c41", "name": "load_p1rlv13633_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b3fe33f-fdcf-42f5-be08-8da15a4d4958"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7ddcbf16-7aee-400a-867b-1625d9b2aae7"}}}}, {"uuid": "97c7df5d-7d20-4f19-a8df-ff4d27029248", "name": "919b3572-0eda-41a4-a30b-d2ebdca56740_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4201171911594663, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7913664471178815, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7d65b2fe-e861-403c-aacd-ff1a8c6f452e", "name": "2528e6e0-563d-4ad3-aef0-30576fc5cb62", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "97c7df5d-7d20-4f19-a8df-ff4d27029248"}}}]}, {"uuid": "c293303e-86dc-4b84-8db2-eedc97de8c50", "name": "load_p1rlv13633_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b3fe33f-fdcf-42f5-be08-8da15a4d4958"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7d65b2fe-e861-403c-aacd-ff1a8c6f452e"}}}}, {"uuid": "09ccac70-d664-460f-b367-a6828d226496", "name": "67a46fb3-067e-4411-9ca2-215ad98086df_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0491915565570302, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1506537762556939, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a9167dd0-eec4-4187-8d69-1b16829d38bb", "name": "0bcb7770-1b34-4ff2-a46b-7ab95042a64a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "09ccac70-d664-460f-b367-a6828d226496"}}}]}, {"uuid": "4174bb0a-452a-46f0-b4e9-42e67e6fb9f1", "name": "load_p1rlv13634_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "987b05d5-9bb9-434d-98b3-623ee5014870"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a9167dd0-eec4-4187-8d69-1b16829d38bb"}}}}, {"uuid": "a60ff0c5-8c9e-4430-bbe3-e61a9c4b32a2", "name": "a3ef54f3-b048-4cf2-b05c-35382e96d908_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0491915565570302, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1506537762556939, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bd28c65e-c687-47b6-afd7-6bd5a68ec166", "name": "461fcc9c-2fd7-4eab-9c4d-c95afcb50ac7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a60ff0c5-8c9e-4430-bbe3-e61a9c4b32a2"}}}]}, {"uuid": "fda346e7-2464-4bd6-8a0c-8e34f4705a79", "name": "load_p1rlv13634_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "987b05d5-9bb9-434d-98b3-623ee5014870"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bd28c65e-c687-47b6-afd7-6bd5a68ec166"}}}}, {"uuid": "03501c13-ff46-45d2-862c-55d026d69060", "name": "fa7fa910-1b72-44d2-88c9-2c5d4f2160ff_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.31125911334339, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6469035988597648, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "99b34702-aefb-4ecf-9662-efca449d746a", "name": "61b45131-846f-46d6-9521-ecd7655136f7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "03501c13-ff46-45d2-862c-55d026d69060"}}}]}, {"uuid": "2a209559-4d1c-4f42-9a45-244995b2999e", "name": "load_p1rlv13635_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc33013a-6a90-46a7-9127-f32288111c14"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "99b34702-aefb-4ecf-9662-efca449d746a"}}}}, {"uuid": "44aa3bec-ea60-44c4-844a-2e34f39d5b9d", "name": "d29dc4e2-aa32-48e4-831a-60e96c6c3418_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.31125911334339, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6469035988597648, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e2c7b5ec-90a9-45c2-bebe-68f2d9cf2fdf", "name": "ceecdb9d-06d8-43cb-8edc-f252113ff87f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "44aa3bec-ea60-44c4-844a-2e34f39d5b9d"}}}]}, {"uuid": "a846042f-a399-4b23-88b5-28a16125f77f", "name": "load_p1rlv13635_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc33013a-6a90-46a7-9127-f32288111c14"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e2c7b5ec-90a9-45c2-bebe-68f2d9cf2fdf"}}}}, {"uuid": "71f32ea8-d8a0-4783-b914-d623b778fdc7", "name": "e316d186-53a6-4f1c-9669-1116390b9f54_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d1ea5d58-0f18-4498-82c6-9d28a73a51a3", "name": "8ae641c4-13c7-49ad-937c-d462cbf99050", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "71f32ea8-d8a0-4783-b914-d623b778fdc7"}}}]}, {"uuid": "dde7312b-6aa6-4692-91ae-bd663ed25cb0", "name": "load_p1rlv13636_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4d3fe62-b327-4fc6-b2aa-795c9475019a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d1ea5d58-0f18-4498-82c6-9d28a73a51a3"}}}}, {"uuid": "50ebb994-5b3b-45b1-81a3-9101ce95a4ed", "name": "896c2f10-b80d-4849-bac7-9f63bbed8a43_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e70432b1-a134-47c3-b5c5-f7b43d821f3f", "name": "a3f8379e-dbf1-4014-ac38-e848ac421bca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "50ebb994-5b3b-45b1-81a3-9101ce95a4ed"}}}]}, {"uuid": "51241fc7-c76e-4bf9-a2ef-90652f4efae3", "name": "load_p1rlv13636_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4d3fe62-b327-4fc6-b2aa-795c9475019a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e70432b1-a134-47c3-b5c5-f7b43d821f3f"}}}}, {"uuid": "4c46cf04-de7e-4d34-bbfc-5cb180717b6e", "name": "16d6aa2b-a551-495d-af08-1e3622784797_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.942829069048031, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.025560880160820944, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "24d7765a-f07e-4e6b-8a5a-4df51bbf830a", "name": "2e3b5926-fa3e-41d3-bc84-1ba6532ae963", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4c46cf04-de7e-4d34-bbfc-5cb180717b6e"}}}]}, {"uuid": "3e2bd199-1a25-451c-a362-e3b28bbac774", "name": "load_p1rlv13637_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30c470ac-39d1-4379-9ae7-790d912bce2c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "24d7765a-f07e-4e6b-8a5a-4df51bbf830a"}}}}, {"uuid": "6a526513-421e-4dbf-9980-3c77433e854d", "name": "ed201a0a-e610-42cf-a003-a35c43a1cb2b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.942829069048031, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.025560880160820944, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b9cd2d9b-dd5e-4ea7-b10e-746c7a702745", "name": "69434e8b-8305-48f1-a6cb-4c5294aaae7f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6a526513-421e-4dbf-9980-3c77433e854d"}}}]}, {"uuid": "a00fc30c-06aa-41c0-a402-c6f017e5d5fc", "name": "load_p1rlv13637_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30c470ac-39d1-4379-9ae7-790d912bce2c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b9cd2d9b-dd5e-4ea7-b10e-746c7a702745"}}}}, {"uuid": "ad6f4b40-f5a4-47a2-964b-8ce502f3d7dc", "name": "11087ee2-87bd-4257-97dd-3f6eed4c5119_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9149869461814677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5767582022429075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "31e2e4b3-dc1e-466a-8d38-c2eac6c6dd63", "name": "9fcf32bf-adc6-4c44-b307-bd05599604cd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ad6f4b40-f5a4-47a2-964b-8ce502f3d7dc"}}}]}, {"uuid": "a15380e8-2648-4beb-8e30-e530c615396d", "name": "load_p1rlv13638_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db3908f7-94f5-43a7-a3de-1f6c9b72ebd4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "31e2e4b3-dc1e-466a-8d38-c2eac6c6dd63"}}}}, {"uuid": "c53ddde5-2039-402e-980c-16a0f3fdc516", "name": "f3182493-3ea8-4919-807c-2e5cf477f3b3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9149869461814677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5767582022429075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2d627562-5a99-4b97-810f-c0c324d6f7b2", "name": "4858ab75-c396-46a5-b5e9-eaf5f0a5acc5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c53ddde5-2039-402e-980c-16a0f3fdc516"}}}]}, {"uuid": "f767f99c-517e-4293-a22e-558482926470", "name": "load_p1rlv13638_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db3908f7-94f5-43a7-a3de-1f6c9b72ebd4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2d627562-5a99-4b97-810f-c0c324d6f7b2"}}}}, {"uuid": "2819f386-8f44-43b5-9d6c-678d19e3f8d7", "name": "3616b5fe-6980-4925-b3b2-eb27bbe1c497_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fd9ff23c-59b5-463a-b58b-27cdc50735ec", "name": "1c5e5eb7-33b3-4022-aaf7-45d672d8e2c0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2819f386-8f44-43b5-9d6c-678d19e3f8d7"}}}]}, {"uuid": "059d17b4-fe64-4805-bcd9-4e46f9e09235", "name": "load_p1rlv13639_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5484eab0-53a8-471c-92ec-29c11c08e740"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fd9ff23c-59b5-463a-b58b-27cdc50735ec"}}}}, {"uuid": "de1bfb30-3df8-4d09-8f71-222396ce7e69", "name": "0e34e63a-5733-4135-bba1-695543fae735_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f13d4010-6d55-4efe-8655-7521453e11e0", "name": "6210fd61-0848-43e8-9c2e-9c3bf700b9d0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "de1bfb30-3df8-4d09-8f71-222396ce7e69"}}}]}, {"uuid": "4f648b6f-b7e4-43fd-a91e-349c254189ca", "name": "load_p1rlv13639_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5484eab0-53a8-471c-92ec-29c11c08e740"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f13d4010-6d55-4efe-8655-7521453e11e0"}}}}, {"uuid": "ab18cebe-9955-405f-9911-fce8c9913a46", "name": "a471f35b-e72d-47c8-a43d-26e19b81faf7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "35d3008f-4e32-404e-a695-2aa7301c897b", "name": "2be52492-a9d7-4b9f-89e5-d7b666a6aff9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ab18cebe-9955-405f-9911-fce8c9913a46"}}}]}, {"uuid": "d9ba6877-fcb0-40d9-b3cc-e37733bf6458", "name": "load_p1rlv13640_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "653bdc0d-5b21-4640-861b-b88ddb5c651a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "35d3008f-4e32-404e-a695-2aa7301c897b"}}}}, {"uuid": "953924ef-3e84-4553-af18-876f4fe0fd5c", "name": "78c3d82f-a316-4d54-ab96-884224053acc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a3df4cb4-5997-4ca3-b6f5-33fe3f32a2bc", "name": "3b687e1f-5ad4-4334-8641-3a62e52c296d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "953924ef-3e84-4553-af18-876f4fe0fd5c"}}}]}, {"uuid": "98cf1c27-dbb5-4800-89c9-71335ef9faa2", "name": "load_p1rlv13640_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "653bdc0d-5b21-4640-861b-b88ddb5c651a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a3df4cb4-5997-4ca3-b6f5-33fe3f32a2bc"}}}}, {"uuid": "ff2bf355-ab80-4b01-998e-54880051bf9f", "name": "459eab03-c1ca-4265-8a6a-9806f03973e9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.725954562298933, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5866148963219024, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4adc22ee-af0f-46e4-b844-5de2777fadf9", "name": "f391628c-8d56-441e-bfda-3cc31ac49988", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ff2bf355-ab80-4b01-998e-54880051bf9f"}}}]}, {"uuid": "d30fa88e-eabd-48e1-b026-ecd2d7782dfc", "name": "load_p1rlv13641_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eb10938-4b73-406c-bed4-0bd01e0bc20d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4adc22ee-af0f-46e4-b844-5de2777fadf9"}}}}, {"uuid": "69cb7403-840f-440d-8a1a-b06c9aa92f0b", "name": "580fa1fd-d871-413b-a8f9-88bddf9d386a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.725954562298933, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5866148963219024, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82fc3122-1cc5-4744-9415-94b09dbd774f", "name": "8c1a17d5-8cde-4691-abb5-c4ad3ea0e1df", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "69cb7403-840f-440d-8a1a-b06c9aa92f0b"}}}]}, {"uuid": "ea414bd3-b37a-4371-a878-61328ce839fa", "name": "load_p1rlv13641_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eb10938-4b73-406c-bed4-0bd01e0bc20d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "82fc3122-1cc5-4744-9415-94b09dbd774f"}}}}, {"uuid": "d09f2a83-b5c9-4235-8679-a4570d4805f2", "name": "20d07da0-dae0-496c-9ca0-289a628db7bd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2219087879829873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3595087789107823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3831569f-5f73-48f2-a9ab-5a3616063410", "name": "3f700706-7d45-470d-8e42-ada404cb71e3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d09f2a83-b5c9-4235-8679-a4570d4805f2"}}}]}, {"uuid": "34ff9b20-48f4-434c-ad64-8773342da568", "name": "load_p1rlv13642_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "479d1486-ed05-44fa-8fab-64035623f267"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3831569f-5f73-48f2-a9ab-5a3616063410"}}}}, {"uuid": "ac8690af-35ef-4cf7-b728-5df66b0ec6ae", "name": "320e79cb-daa5-4360-97d5-7529918e9f19_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2219087879829873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3595087789107823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a4d6c511-9b88-47d5-9bf8-534ffb5d64a7", "name": "b03c670e-e129-426d-aa5d-d6c19f68019a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ac8690af-35ef-4cf7-b728-5df66b0ec6ae"}}}]}, {"uuid": "870c0741-671e-4fa5-8178-f061a1a30553", "name": "load_p1rlv13642_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "479d1486-ed05-44fa-8fab-64035623f267"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a4d6c511-9b88-47d5-9bf8-534ffb5d64a7"}}}}, {"uuid": "bd325d4d-1161-45e0-a72f-a63d6d594d11", "name": "0118f287-e659-44ea-b124-d4d4f7bd2f1f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0be1befb-4b3d-4ad7-a4af-35cac5f8452c", "name": "7f87bdbe-b5a6-4d42-b7eb-dac0ca68e3e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bd325d4d-1161-45e0-a72f-a63d6d594d11"}}}]}, {"uuid": "5ae8d23c-13f6-490b-bd31-a17c15dfad21", "name": "load_p1rlv13643_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20009de0-cbe7-4b4f-a046-425a6ae71925"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0be1befb-4b3d-4ad7-a4af-35cac5f8452c"}}}}, {"uuid": "c89ef2e0-f868-4dcd-bc19-b27e14951e25", "name": "f557316c-bda0-43e6-a08d-0bce1708c1af_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "393b1cad-6b55-4973-b28a-56692c2e4274", "name": "b9dca927-1456-4f14-a146-5f470c572560", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c89ef2e0-f868-4dcd-bc19-b27e14951e25"}}}]}, {"uuid": "0602d8b5-0a43-4a93-ba8a-e7eff78736a5", "name": "load_p1rlv13643_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20009de0-cbe7-4b4f-a046-425a6ae71925"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "393b1cad-6b55-4973-b28a-56692c2e4274"}}}}, {"uuid": "c1bbb515-b8c7-4c98-87e1-d29e17219acf", "name": "2489afdb-0ac5-4c87-b749-afc4d5c17807_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "45444b45-4777-4dcb-a5b6-a5318dd48642", "name": "95c301f7-5f36-46bb-a632-f91056dfd942", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c1bbb515-b8c7-4c98-87e1-d29e17219acf"}}}]}, {"uuid": "34afd116-cf35-4dee-8632-2c2db844aa7c", "name": "load_p1rlv13645_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1acad56e-b6d6-4fa7-a925-f242c1558eef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "45444b45-4777-4dcb-a5b6-a5318dd48642"}}}}, {"uuid": "729dec84-6190-48e8-8f28-1f1ac1ed1cae", "name": "5f2bf744-bd3e-4593-8c59-6ee59ce6ec97_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "545fd949-ca5f-4021-a9cb-70214da669b1", "name": "8e52d775-cd93-470f-a449-467dd1bd7da5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "729dec84-6190-48e8-8f28-1f1ac1ed1cae"}}}]}, {"uuid": "bab4d514-42f6-48f7-a8f0-3912a1e1a1c8", "name": "load_p1rlv13645_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1acad56e-b6d6-4fa7-a925-f242c1558eef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "545fd949-ca5f-4021-a9cb-70214da669b1"}}}}, {"uuid": "7de9fa63-d7d8-42be-8950-590bc369ae2a", "name": "1d3651b2-1ade-49fb-ab57-a9b07ad20ade_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4519136613739017, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7054970531635038, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c531f4fd-237f-4a4e-b8df-650e5c906732", "name": "956fe972-4e01-481c-84e7-1b6cbfeb7f20", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7de9fa63-d7d8-42be-8950-590bc369ae2a"}}}]}, {"uuid": "5599b81a-cb04-4ba8-95c5-f2ce0818c160", "name": "load_p1rlv13646_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fe0466e-cce5-4c6c-b13f-cedd349b6944"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c531f4fd-237f-4a4e-b8df-650e5c906732"}}}}, {"uuid": "d90b4bd1-901f-4ed8-b6c2-18f91fb1fbe0", "name": "288608e5-0375-438e-9815-90b527a03a3c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4519136613739017, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7054970531635038, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "615b821c-a77c-4577-9683-6b35a7e599b8", "name": "27907f11-b1a1-49ea-ac02-b474b0ee1296", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d90b4bd1-901f-4ed8-b6c2-18f91fb1fbe0"}}}]}, {"uuid": "49d1c147-c2e7-4c73-8f8c-c68335fae76f", "name": "load_p1rlv13646_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fe0466e-cce5-4c6c-b13f-cedd349b6944"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "615b821c-a77c-4577-9683-6b35a7e599b8"}}}}, {"uuid": "8ded91d9-819a-41a7-9317-5644c2b21466", "name": "ea7f762c-ce75-4d60-ace7-be83382b67ef_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7813411640480736, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4182052484168413, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "badfcc26-ec8f-4d69-827c-6970fb6fffba", "name": "2a06c444-3e0e-4bed-901f-2fcc499def0b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ded91d9-819a-41a7-9317-5644c2b21466"}}}]}, {"uuid": "a8732407-5084-4d7d-bc08-770676d828cd", "name": "load_p1rlv13647_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8753d37-07f1-45c6-a483-43cbfb6bf107"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "badfcc26-ec8f-4d69-827c-6970fb6fffba"}}}}, {"uuid": "b5e8a61b-47e3-4497-a372-da74225c037d", "name": "698ba49f-a12a-4a1c-a60e-3a4224a3fdf4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7813411640480736, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4182052484168413, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9905e932-f6db-4c5a-9953-3ae517967290", "name": "a8e4cb2a-552f-477b-990a-7d4864067f6b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5e8a61b-47e3-4497-a372-da74225c037d"}}}]}, {"uuid": "929e7d4b-7ca0-420b-a59f-8131acee3c6e", "name": "load_p1rlv13647_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8753d37-07f1-45c6-a483-43cbfb6bf107"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9905e932-f6db-4c5a-9953-3ae517967290"}}}}, {"uuid": "d9f54d7b-c79c-4e40-98df-ea703f5ac70d", "name": "e5c3a58c-b408-4539-89ca-bf1cf35ce61e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1343287185333217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10429894918818222, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "090bd7d6-3f1f-4e27-b141-78a2939dc01f", "name": "01cc5f96-812a-4b61-b1ee-ae944d1e9e2f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d9f54d7b-c79c-4e40-98df-ea703f5ac70d"}}}]}, {"uuid": "655fa1cb-f8f2-445b-8380-e4606ad75131", "name": "load_p1rlv13648_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62a29ac5-7227-43b2-b602-b1189cc93839"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "090bd7d6-3f1f-4e27-b141-78a2939dc01f"}}}}, {"uuid": "8a0039a2-6d46-4a15-89fd-0e48ddfa2026", "name": "13fc6f7a-f857-4fb9-9f1c-3fa2e404205f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1343287185333217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10429894918818222, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "edd294c3-09a4-4f8a-843d-59f0732f18cd", "name": "2de0392e-0063-46cd-873d-8218831e2e65", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a0039a2-6d46-4a15-89fd-0e48ddfa2026"}}}]}, {"uuid": "7f04e3b5-99a3-417b-9ea6-f2daab8d6fe8", "name": "load_p1rlv13648_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62a29ac5-7227-43b2-b602-b1189cc93839"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "edd294c3-09a4-4f8a-843d-59f0732f18cd"}}}}, {"uuid": "c0691bdd-89f2-488e-914c-503562a2c816", "name": "d5241df9-210a-4632-ba1f-31f5903cefa6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "905b259c-5f98-4478-a1d2-fcbedf1ada7e", "name": "03f14100-0af1-4c78-872a-9c54c3c9bdad", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c0691bdd-89f2-488e-914c-503562a2c816"}}}]}, {"uuid": "274e8dac-f955-4b5d-877d-34b969f045d4", "name": "load_p1rlv13649_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43867e2f-79ee-4cec-bed3-0cad0727118c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "905b259c-5f98-4478-a1d2-fcbedf1ada7e"}}}}, {"uuid": "adf27202-e69a-467a-9e93-2b422c27b8f5", "name": "b86a783e-92c5-4b8b-8f04-8de9193fa62b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b7b902de-dea3-4126-ab0b-8d5a36d63c29", "name": "03e22a3c-06dd-436a-a577-32b9e21ca18c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "adf27202-e69a-467a-9e93-2b422c27b8f5"}}}]}, {"uuid": "06d40c7c-d7d4-443a-b8aa-91d579b4708f", "name": "load_p1rlv13649_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43867e2f-79ee-4cec-bed3-0cad0727118c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b7b902de-dea3-4126-ab0b-8d5a36d63c29"}}}}, {"uuid": "d7d5af8b-daf2-4e4e-9b0d-ed795ed513cc", "name": "658f477d-eaba-4943-a7ee-2a81555af2a2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2570744264864886, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.02246974709606756, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bc03626c-630c-437c-81dd-3315b3978341", "name": "48a360e8-d80c-47b5-b6ba-5ff066efe523", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d7d5af8b-daf2-4e4e-9b0d-ed795ed513cc"}}}]}, {"uuid": "e539658e-9b51-4f32-8034-dfd8818aab1c", "name": "load_p1rlv13650_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fa2041e-34c4-4f1f-a329-74969c3da75f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bc03626c-630c-437c-81dd-3315b3978341"}}}}, {"uuid": "f6a3c7a8-3d24-4f7b-b91c-cb9c3f0b4f3f", "name": "e9d2125e-d841-4d9e-9531-0deabe5a9e78_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2570744264864886, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.02246974709606756, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d0336c96-d254-48cb-a8ab-5ca8ee4e509a", "name": "f759eb0e-e52e-4935-8183-af965777f183", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f6a3c7a8-3d24-4f7b-b91c-cb9c3f0b4f3f"}}}]}, {"uuid": "21214c31-8a2f-45c9-91dd-98abd124759a", "name": "load_p1rlv13650_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fa2041e-34c4-4f1f-a329-74969c3da75f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d0336c96-d254-48cb-a8ab-5ca8ee4e509a"}}}}, {"uuid": "dced574f-ef99-4a2b-ad7a-a26535c32b88", "name": "bed9e268-e4a4-4f24-85be-f266452ffd30_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d0c5d89c-bf53-4014-9e6c-fa9efe4580a4", "name": "4ef69988-cd3c-42a1-a5d2-6cddc8fe53ce", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dced574f-ef99-4a2b-ad7a-a26535c32b88"}}}]}, {"uuid": "4408d259-bb84-44ec-b02f-067428660b1d", "name": "load_p1rlv13651_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c808261e-a49e-4954-bdc4-a8b63d0ee25b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d0c5d89c-bf53-4014-9e6c-fa9efe4580a4"}}}}, {"uuid": "d1fc4eeb-9cc6-4172-b6d4-7289ca5ec624", "name": "a178b7f7-d214-4e92-b211-dec0140ceedb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4aa2831b-6bb2-4cc4-b21f-c46883712692", "name": "e7ae22a7-1090-4452-b54d-fd3f31d49079", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d1fc4eeb-9cc6-4172-b6d4-7289ca5ec624"}}}]}, {"uuid": "373dc048-2ea4-417c-8487-61c88a796053", "name": "load_p1rlv13651_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c808261e-a49e-4954-bdc4-a8b63d0ee25b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4aa2831b-6bb2-4cc4-b21f-c46883712692"}}}}, {"uuid": "69dfdb76-e6ee-4abd-9f38-d45756695404", "name": "36741a16-86b3-44a9-a284-dc5f6ede04b7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9eb220af-0b1b-474d-8a61-2dc6f753fbc0", "name": "ad9f0501-1f15-475c-ada7-35b8c17f18d2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "69dfdb76-e6ee-4abd-9f38-d45756695404"}}}]}, {"uuid": "e3181116-934c-4c25-bd6e-f1e06020124d", "name": "load_p1rlv13652_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3310c14a-d1ee-4d0c-8428-d002703c61d5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9eb220af-0b1b-474d-8a61-2dc6f753fbc0"}}}}, {"uuid": "b2c54594-b1f9-4654-a1b7-420fb0dc3ecf", "name": "62d8c279-f33b-48e5-a06f-2b23ab118224_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2f905575-f631-4ca9-b41d-5ee46496fbfb", "name": "a4c287e9-487e-469e-90ae-cc3f25dee8a0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b2c54594-b1f9-4654-a1b7-420fb0dc3ecf"}}}]}, {"uuid": "e4a891ed-1399-4dae-bb21-1c5fd0c3f2ff", "name": "load_p1rlv13652_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3310c14a-d1ee-4d0c-8428-d002703c61d5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2f905575-f631-4ca9-b41d-5ee46496fbfb"}}}}, {"uuid": "e8bc5267-78dd-4572-b99c-9781edf1a03b", "name": "79722852-e477-4e90-bf4d-de348b8f8c31_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "304e5081-f254-4df0-aae5-f92b694735e8", "name": "9c23987e-3fbd-447d-900b-dd0b801ca8c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e8bc5267-78dd-4572-b99c-9781edf1a03b"}}}]}, {"uuid": "604756e6-8f23-42e6-8335-c7165a48f07b", "name": "load_p1rlv13653_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c61a243-7736-46a0-a950-7cc811381158"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "304e5081-f254-4df0-aae5-f92b694735e8"}}}}, {"uuid": "95b6cfff-b677-446f-8b23-227e177a695b", "name": "48a93325-7a1d-4671-8fae-2adbe2094009_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "70026483-7529-4ffe-8f3b-b6cae4805814", "name": "4e95a876-9d1b-41a0-865f-9347f0ce019a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "95b6cfff-b677-446f-8b23-227e177a695b"}}}]}, {"uuid": "cacbe185-64b6-4e12-b4d8-3d92da57d657", "name": "load_p1rlv13653_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c61a243-7736-46a0-a950-7cc811381158"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "70026483-7529-4ffe-8f3b-b6cae4805814"}}}}, {"uuid": "4215e0af-da77-4d2e-a0be-8d321ac4f6d0", "name": "7ff3ae74-0d5b-45c6-b5dd-9a103a883b8c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82b2e12e-7a54-461c-9aeb-a222f058ec8e", "name": "8a57889c-3821-45cc-9438-a0a84fa702c4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4215e0af-da77-4d2e-a0be-8d321ac4f6d0"}}}]}, {"uuid": "b972ad59-d151-468c-bbd8-0fe62c96767f", "name": "load_p1rlv13654_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7be734c-88e2-42c1-8061-f4632bd05759"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "82b2e12e-7a54-461c-9aeb-a222f058ec8e"}}}}, {"uuid": "e3fd7e6b-3be9-468b-bb42-7a08e9ec8e27", "name": "e67ffab9-dfac-41eb-bbf4-9ebff2f3e456_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1fc8c2fb-8515-4441-b436-ab518d71744e", "name": "cb0ab9b6-7b48-4770-9f04-f90333d35c5e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e3fd7e6b-3be9-468b-bb42-7a08e9ec8e27"}}}]}, {"uuid": "d10b8868-8b0b-47ff-be2a-454a09676e6b", "name": "load_p1rlv13654_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7be734c-88e2-42c1-8061-f4632bd05759"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1fc8c2fb-8515-4441-b436-ab518d71744e"}}}}, {"uuid": "56b5f355-041e-4dba-ba09-03809c3c5b2e", "name": "a40afe02-c157-4c26-9cf8-bd7fa2dd4dd2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6323867069620042, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.40255171211713736, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "baeaae15-0168-4ba2-837d-7809208f82e6", "name": "7dd8ae54-e6f6-436b-a88f-4802f0aee048", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "56b5f355-041e-4dba-ba09-03809c3c5b2e"}}}]}, {"uuid": "349940a9-30e6-4bcf-b4ea-7dc077419d78", "name": "load_p1rlv13656_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8c0a04e-6e22-4da5-9907-7ae8097deb10"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "baeaae15-0168-4ba2-837d-7809208f82e6"}}}}, {"uuid": "b952e3d4-9a7c-40a3-9164-9d0dd955044a", "name": "8dc31abf-deda-4dfa-b7bf-e8f0ac40e338_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6323867069620042, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.40255171211713736, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c0c3b87a-70c4-4b94-b70b-f055b01e00b8", "name": "7196cb5a-f515-4eb5-aa7d-88db8da976a5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b952e3d4-9a7c-40a3-9164-9d0dd955044a"}}}]}, {"uuid": "37c16384-4d78-48e7-881c-0d1f7e0836e3", "name": "load_p1rlv13656_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8c0a04e-6e22-4da5-9907-7ae8097deb10"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c0c3b87a-70c4-4b94-b70b-f055b01e00b8"}}}}, {"uuid": "1f18b628-04c5-4373-aba7-c517e5f25cfd", "name": "286482c8-f090-4cae-8a2e-a73d7db99feb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3136780250521567, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6274781256964336, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "81b85d52-3498-43a8-936c-0438a3a1e77a", "name": "624e03d2-a2a3-40e9-a4ce-1cb0baf735ec", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1f18b628-04c5-4373-aba7-c517e5f25cfd"}}}]}, {"uuid": "65dd228a-3e18-4462-8f6e-0b8ef359f3c7", "name": "load_p1rlv13659_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "122e0772-7de6-4117-b1d3-caafbbbc8e22"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "81b85d52-3498-43a8-936c-0438a3a1e77a"}}}}, {"uuid": "4a0d6619-6653-4170-94df-7f94241e7756", "name": "e731fb7a-2aac-4405-9829-9a124878e978_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3136780250521567, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6274781256964336, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a9b8aef4-770c-4605-91fb-cf5f65bac8ad", "name": "cc3f61f1-61e1-4095-be99-dd251406fe77", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4a0d6619-6653-4170-94df-7f94241e7756"}}}]}, {"uuid": "869b76e9-b831-42f3-8bfe-4034fcee94b6", "name": "load_p1rlv13659_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "122e0772-7de6-4117-b1d3-caafbbbc8e22"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a9b8aef4-770c-4605-91fb-cf5f65bac8ad"}}}}, {"uuid": "1e3a44b0-0311-4a0a-920f-31d3cb8071ea", "name": "a6035deb-21e9-40d2-b1e3-5a81cf2ca1fa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.451252731053624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.713074208581691, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a7a72458-f0a7-4e0f-bab5-35516828e6fa", "name": "05101890-58cb-4a6a-998d-7a80d1a38c47", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1e3a44b0-0311-4a0a-920f-31d3cb8071ea"}}}]}, {"uuid": "aa4f58db-b7d9-429e-a7b8-d50bf374567d", "name": "load_p1rlv13660_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3d6fd13-2f04-4f23-97a3-cdf99159174c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a7a72458-f0a7-4e0f-bab5-35516828e6fa"}}}}, {"uuid": "f7ac0d69-63e9-40a3-81c8-4d9210203563", "name": "68272a3f-b73a-49ac-b04a-74e14740c79c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.451252731053624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.713074208581691, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b2a24286-1b0d-43bd-afe4-9a13c48cf1dd", "name": "9722d5dd-1118-4ef5-be44-6db735db2110", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f7ac0d69-63e9-40a3-81c8-4d9210203563"}}}]}, {"uuid": "d8533016-a154-475b-ae9b-fe6c0e150256", "name": "load_p1rlv13660_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3d6fd13-2f04-4f23-97a3-cdf99159174c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b2a24286-1b0d-43bd-afe4-9a13c48cf1dd"}}}}, {"uuid": "49b8597a-96da-4788-9afb-f420e2d395d7", "name": "f0537617-b121-403f-ba70-6877fc568219_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "16d19764-29c0-4188-95fd-b5ccbb16d11f", "name": "2e81f190-f3c8-4018-9677-fd85b083ba16", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "49b8597a-96da-4788-9afb-f420e2d395d7"}}}]}, {"uuid": "fd271e1a-15aa-4d19-ac28-1921b1f5a1a5", "name": "load_p1rlv13661_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ef8e6ec-86d3-429c-89b4-6c7260701e70"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "16d19764-29c0-4188-95fd-b5ccbb16d11f"}}}}, {"uuid": "6ee4c0dc-6e94-42a4-883c-00fe63e6c34a", "name": "758a5607-2d31-45ef-b75f-52aed25d24fd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ff2dc44d-7d99-4780-9681-ce8f29bd282b", "name": "0eefbf1a-f69c-4f42-a699-ea939db89f8c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6ee4c0dc-6e94-42a4-883c-00fe63e6c34a"}}}]}, {"uuid": "a56c3c6c-7ab4-4461-850f-b48a81dc968d", "name": "load_p1rlv13661_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ef8e6ec-86d3-429c-89b4-6c7260701e70"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ff2dc44d-7d99-4780-9681-ce8f29bd282b"}}}}, {"uuid": "f8133e03-31d5-42d7-bd88-4cc213bcb5b7", "name": "0ba1e3ee-b48a-4b3d-b892-f58040d5479b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2219087879829873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3595087789107823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "df9dad07-8131-40cb-9a8f-064c58479727", "name": "2f22329d-168a-44bd-9637-93fb93b0ccc0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8133e03-31d5-42d7-bd88-4cc213bcb5b7"}}}]}, {"uuid": "14568d59-4779-4b82-bd4c-7d6f84a4677a", "name": "load_p1rlv13662_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e55b944-ffad-47bf-8348-799afa4c7a1d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "df9dad07-8131-40cb-9a8f-064c58479727"}}}}, {"uuid": "50e89d97-6a00-4d85-8890-0efccc86d1d6", "name": "2fad6a38-3c6a-498d-9e60-183787ca00b4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2219087879829873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3595087789107823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4980cbef-343f-4f1c-8a0c-b1bb4d46f7a8", "name": "888f46ed-ff0c-4187-a262-a4883c066470", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "50e89d97-6a00-4d85-8890-0efccc86d1d6"}}}]}, {"uuid": "99b31d76-0371-49fb-aee3-ea5f640aca86", "name": "load_p1rlv13662_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e55b944-ffad-47bf-8348-799afa4c7a1d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4980cbef-343f-4f1c-8a0c-b1bb4d46f7a8"}}}}, {"uuid": "35f09a5f-e76d-4143-a0a1-6b6528905ecf", "name": "e92bb2ae-6b5b-4423-90a4-55f00d52ee1d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4037437915385973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5086059213404144, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c6cf5817-c9e9-42bd-8fa8-1d2f0deb9b7a", "name": "e9e871ed-52e9-4ea3-a1e7-ee2dce5ddc1d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "35f09a5f-e76d-4143-a0a1-6b6528905ecf"}}}]}, {"uuid": "69ddfb6d-3d94-4dab-81e2-68581c898457", "name": "load_p1rlv13663_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54887ca7-ae23-42d0-a715-aed8baa38ade"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c6cf5817-c9e9-42bd-8fa8-1d2f0deb9b7a"}}}}, {"uuid": "553e3b41-b83a-479c-9900-962640ead61c", "name": "8fdeee45-7875-4773-939f-6c2eededbcea_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4037437915385973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5086059213404144, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "00a29a22-4c22-47bf-bd3a-c7811900b5c7", "name": "15aea7ce-4acb-45f9-9a2d-6cec7461ff24", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "553e3b41-b83a-479c-9900-962640ead61c"}}}]}, {"uuid": "de470297-775d-41a9-a47c-c5d09e70a32c", "name": "load_p1rlv13663_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54887ca7-ae23-42d0-a715-aed8baa38ade"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "00a29a22-4c22-47bf-bd3a-c7811900b5c7"}}}}, {"uuid": "b93948c1-dbe7-4ace-bdfd-789dc22a235e", "name": "424fbac6-cc35-412a-8694-f8c7ff2dbe5d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.171921265639173, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.29621618517422543, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "370843e6-cc97-4f14-bd5d-71ce37f2fd6d", "name": "da0ddf58-b766-4b91-93f4-ce4eac28b240", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b93948c1-dbe7-4ace-bdfd-789dc22a235e"}}}]}, {"uuid": "f2fcf549-f097-41f8-8ff2-c5cee47e5668", "name": "load_p1rlv13664_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70cf02cc-8f1b-48ab-b9e6-50c3e58ad9ae"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "370843e6-cc97-4f14-bd5d-71ce37f2fd6d"}}}}, {"uuid": "3116d69b-7117-4fd8-b4e9-76d7811456b4", "name": "7fbb6319-51f4-447f-b58e-f3c627cbc17b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.171921265639173, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.29621618517422543, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a81205d-cea1-4b5b-bf2b-ef3f9c494db7", "name": "1681ffde-b20c-43e2-be25-1228adb048cb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3116d69b-7117-4fd8-b4e9-76d7811456b4"}}}]}, {"uuid": "e5513cae-ff8c-4f6a-82a0-f7fe9d4d4983", "name": "load_p1rlv13664_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70cf02cc-8f1b-48ab-b9e6-50c3e58ad9ae"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a81205d-cea1-4b5b-bf2b-ef3f9c494db7"}}}}, {"uuid": "561dd82a-ae45-4f18-b612-97489aafacb7", "name": "0510710f-c864-4bc0-a449-3dd4188e126d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6009666033769583, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.30487867399122176, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "298f4a0a-6d5a-4036-9050-3b41e1d5f3a5", "name": "fa52f6fb-68d6-49a3-a8ed-829fba2b4bfa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "561dd82a-ae45-4f18-b612-97489aafacb7"}}}]}, {"uuid": "f19c4f4e-5559-4646-b2ae-a189dca4a78e", "name": "load_p1rlv13666_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5868c24b-2a58-459b-8650-a6072241aca8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "298f4a0a-6d5a-4036-9050-3b41e1d5f3a5"}}}}, {"uuid": "2d6621c8-2e92-45df-b7e3-67b7c537e629", "name": "68f1ea3e-f95b-4303-b2a6-98908bdf41d3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6009666033769583, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.30487867399122176, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ce9c0f2e-efd6-4773-b074-1efb58ce18f8", "name": "2d068a03-d5cf-44f3-8e39-40e41e6e57b1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2d6621c8-2e92-45df-b7e3-67b7c537e629"}}}]}, {"uuid": "65c1c2bb-7594-4118-8ba2-bbd216d7ea0f", "name": "load_p1rlv13666_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5868c24b-2a58-459b-8650-a6072241aca8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ce9c0f2e-efd6-4773-b074-1efb58ce18f8"}}}}, {"uuid": "06e41b5d-b214-4e44-8975-b0649d93fe60", "name": "59d31c8d-fdd0-46b2-9502-0fd377ff435a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10b6ca4c-b522-4c46-a7f0-743befb358a6", "name": "a202078d-d353-405c-8692-4abd9581de19", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "06e41b5d-b214-4e44-8975-b0649d93fe60"}}}]}, {"uuid": "4f0a7fbd-d525-4b67-b610-ecc4dbc20dee", "name": "load_p1rlv13667_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d6cdd514-204d-4a86-b0f3-a9bc4990a2aa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10b6ca4c-b522-4c46-a7f0-743befb358a6"}}}}, {"uuid": "ac4210ab-7389-4005-a2ef-073ae6873999", "name": "d8bea9da-89f9-4072-860e-9420f53c46e6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e534cee0-6684-4f52-bc0e-6cd84309dc93", "name": "dea8c815-395b-4c6a-899d-054e1a145d92", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ac4210ab-7389-4005-a2ef-073ae6873999"}}}]}, {"uuid": "858e4943-fb33-4590-9ee4-155d15a843e1", "name": "load_p1rlv13667_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d6cdd514-204d-4a86-b0f3-a9bc4990a2aa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e534cee0-6684-4f52-bc0e-6cd84309dc93"}}}}, {"uuid": "c08997c7-db55-40c4-bf71-998de5dc6a71", "name": "9355b24d-6e65-4b80-8e20-c4cf4483930b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.243385388928283, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18185664736822973, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "843280bd-9358-4b99-85d7-c0dd09bf6f7b", "name": "8c70ecf7-eaa5-4b44-adf6-b23c782fbcc0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c08997c7-db55-40c4-bf71-998de5dc6a71"}}}]}, {"uuid": "823f5fdd-d975-4ec1-a4c5-7eb9e943a700", "name": "load_p1rlv13669_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "607d3b54-2cea-476b-afe2-ea40c6c02ddc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "843280bd-9358-4b99-85d7-c0dd09bf6f7b"}}}}, {"uuid": "669b92ac-4005-42e9-989d-1da0b09a1c0d", "name": "c9ff654e-5d95-48b2-9c5d-aaa5f5920f16_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.243385388928283, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18185664736822973, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "13843380-871f-4a44-97d5-19edb10e8cd1", "name": "7857066d-2d99-4610-9671-18cdf4e6d73f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "669b92ac-4005-42e9-989d-1da0b09a1c0d"}}}]}, {"uuid": "42d869a0-9001-4c85-96d5-1bd32d6d9a19", "name": "load_p1rlv13669_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "607d3b54-2cea-476b-afe2-ea40c6c02ddc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "13843380-871f-4a44-97d5-19edb10e8cd1"}}}}, {"uuid": "c824570f-41c3-4658-98ee-b5d38899b6fb", "name": "5420d868-605b-4836-9448-e01ad2898845_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ad43811a-0dce-48b2-8dad-193d26dc5c7e", "name": "94d0f2f7-b64e-4f42-9c92-9cbce5357977", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c824570f-41c3-4658-98ee-b5d38899b6fb"}}}]}, {"uuid": "4eec0c4e-00d7-4bec-949d-5a1648f8cc2e", "name": "load_p1rlv13670_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce53d307-fc73-487a-8f6a-3a0e0787bf79"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ad43811a-0dce-48b2-8dad-193d26dc5c7e"}}}}, {"uuid": "cd9f93af-ec5b-4d27-9244-d0d906a65dca", "name": "ddd68ff7-775d-4432-b32b-67e2f60fa9fa_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fadec189-327c-4c49-9a41-e9f44f088a90", "name": "f30ed151-47fc-40fe-9c37-0b39891ad867", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cd9f93af-ec5b-4d27-9244-d0d906a65dca"}}}]}, {"uuid": "3c0757fe-078a-4f99-9037-7bf31dd78c2c", "name": "load_p1rlv13670_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce53d307-fc73-487a-8f6a-3a0e0787bf79"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fadec189-327c-4c49-9a41-e9f44f088a90"}}}}, {"uuid": "cce1d914-3897-415d-94c9-0bda66e7584b", "name": "a9637591-c10b-4105-8b34-4ea3820ade8e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9288466752414104, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5041700498617779, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "83e11efa-0cb8-4d77-a6fb-48c4441831cd", "name": "c980a120-d7d0-4495-9d41-52fcb27a478c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cce1d914-3897-415d-94c9-0bda66e7584b"}}}]}, {"uuid": "a20a8092-569d-43be-b17c-299bca2d34fb", "name": "load_p1rlv13671_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2f95b8b-190c-4df2-9dd2-daee5efde34b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "83e11efa-0cb8-4d77-a6fb-48c4441831cd"}}}}, {"uuid": "98e84956-76ab-4a79-ac91-0c753fc10395", "name": "4ecc3f34-13d4-49e2-9636-c3822922023a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9288466752414104, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5041700498617779, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "406dfc6a-2106-4f9a-bb1a-e36b1874ac5c", "name": "865d5e0b-db3c-441b-a3ec-9d306b528262", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "98e84956-76ab-4a79-ac91-0c753fc10395"}}}]}, {"uuid": "05cffae3-c68a-4ca1-9c2c-6d472dcac594", "name": "load_p1rlv13671_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2f95b8b-190c-4df2-9dd2-daee5efde34b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "406dfc6a-2106-4f9a-bb1a-e36b1874ac5c"}}}}, {"uuid": "eac080d0-ce9f-4a11-9e89-064e9652e90a", "name": "5c0125ca-ef8b-4355-ad66-e1e6c40caf68_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c6d2010-b22f-4f29-a013-2e6988795d7b", "name": "80d25aa9-7fde-4ccf-a1b1-35cd5fab65b4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eac080d0-ce9f-4a11-9e89-064e9652e90a"}}}]}, {"uuid": "8d4e629f-b47d-4680-be3c-57609d082098", "name": "load_p1rlv13672_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32bec8ad-b312-4502-a2a1-6a4c9b2dd87a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c6d2010-b22f-4f29-a013-2e6988795d7b"}}}}, {"uuid": "029cbe02-f40e-47e9-8a6a-d7387d5abab2", "name": "50f4da33-f660-4b22-bf6b-fe34737078fb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3b0fd302-f287-459a-ae23-7476c857531f", "name": "a26442c2-5ac1-47c4-a2b3-b4ab086af933", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "029cbe02-f40e-47e9-8a6a-d7387d5abab2"}}}]}, {"uuid": "8a1bf579-c074-4fed-986e-85b6783e25cc", "name": "load_p1rlv13672_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32bec8ad-b312-4502-a2a1-6a4c9b2dd87a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3b0fd302-f287-459a-ae23-7476c857531f"}}}}, {"uuid": "693b4667-daea-4e40-bfff-dd1959206f97", "name": "fc721459-308e-4879-bc34-b613e7f7c85c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7935386970404408, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "55f52881-bd1e-4e64-92b8-eebaa9951c1d", "name": "d510a2f4-a1e2-4e21-af2f-a876e4b9c568", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "693b4667-daea-4e40-bfff-dd1959206f97"}}}]}, {"uuid": "e3e6f22c-25bc-4daa-ba19-48a3f4bf03d1", "name": "load_p1rlv13673_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9467d2d3-ad80-4bc7-aa9f-cd6e76494552"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "55f52881-bd1e-4e64-92b8-eebaa9951c1d"}}}}, {"uuid": "8fca9d32-1a27-4937-ab5d-7af131c409a2", "name": "0537dda4-bdba-4b71-b8b6-1d9426ed5389_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7935386970404408, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d8163229-e0c4-41cf-a995-7a616b434812", "name": "2c77a221-82e8-4961-ae91-366e528cbae6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8fca9d32-1a27-4937-ab5d-7af131c409a2"}}}]}, {"uuid": "189e9cc4-5dee-4a05-b818-18d261acbaf3", "name": "load_p1rlv13673_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9467d2d3-ad80-4bc7-aa9f-cd6e76494552"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d8163229-e0c4-41cf-a995-7a616b434812"}}}}, {"uuid": "cdcbb941-fd4c-47f7-99d4-b5833522ee8e", "name": "fcd8614f-b0c9-4179-a0bd-6de5a6d6295a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3711169311548215, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.698133467399761, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a39d1a35-4104-4eed-bd3a-065a7b917b55", "name": "ec8fff74-3bfd-4245-a89b-a6c8db3c0025", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cdcbb941-fd4c-47f7-99d4-b5833522ee8e"}}}]}, {"uuid": "a82d7413-7003-40aa-a574-389c577ecef9", "name": "load_p1rlv13675_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c532e298-bdd5-416e-8ebe-a082489ffee6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a39d1a35-4104-4eed-bd3a-065a7b917b55"}}}}, {"uuid": "f8c09000-4b28-45b6-a38a-de39aa272539", "name": "3bd3720d-ffed-4317-a656-460de94fe06e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3711169311548215, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.698133467399761, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8c8addae-8650-47cd-9563-df844c7de159", "name": "f50d2292-b086-4db1-8466-6afb06457711", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8c09000-4b28-45b6-a38a-de39aa272539"}}}]}, {"uuid": "60ee37ce-bbe8-486f-b6e2-c9b26c754bd1", "name": "load_p1rlv13675_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c532e298-bdd5-416e-8ebe-a082489ffee6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8c8addae-8650-47cd-9563-df844c7de159"}}}}, {"uuid": "0fff1cf9-f15e-4586-b11a-72f58c6f6003", "name": "a98e48cc-d122-4e98-a9c0-1fadf8c53d63_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3cc3a673-8856-4f3b-9c8f-f7daaa17fb65", "name": "cb431138-581d-4918-b0c8-cae906037191", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0fff1cf9-f15e-4586-b11a-72f58c6f6003"}}}]}, {"uuid": "b627c3b4-2b03-4e8f-a8be-61431fb5fd12", "name": "load_p1rlv13676_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8df1a69e-5b18-4eef-ab60-543a97257297"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3cc3a673-8856-4f3b-9c8f-f7daaa17fb65"}}}}, {"uuid": "6a22ceca-21eb-466d-9d9e-c24cc239af5d", "name": "742fed2a-5e6e-4add-9b6b-9ac27249fd3a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a0765586-2c2e-40b8-b1cf-e8c980220f17", "name": "7629d3d9-c942-4811-958e-2bd2ac62601e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6a22ceca-21eb-466d-9d9e-c24cc239af5d"}}}]}, {"uuid": "131c54ad-6996-45ed-96ad-bca519031e12", "name": "load_p1rlv13676_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8df1a69e-5b18-4eef-ab60-543a97257297"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a0765586-2c2e-40b8-b1cf-e8c980220f17"}}}}, {"uuid": "2159daa7-94bc-4a90-b7e3-9380fe01ef2f", "name": "95d4f202-1a21-460c-bb0e-64573f95dc6f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 12.611907582113087, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.885290064059574, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "526c56c3-9921-4fa4-a847-f1aaf7e2bf36", "name": "f0684b75-8c89-4aee-b462-56154d3d838e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2159daa7-94bc-4a90-b7e3-9380fe01ef2f"}}}]}, {"uuid": "38ef36d4-caaa-44ce-822a-172645112c72", "name": "load_p1rlv13677_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9aa7e62-8974-4ef0-aa5a-bcd545245aea"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "526c56c3-9921-4fa4-a847-f1aaf7e2bf36"}}}}, {"uuid": "d47e11d8-d612-4fd1-8682-c3435b00d0fa", "name": "38ec15b0-ee6b-4572-9bfb-3094e633a9c6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 12.611907582113087, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.885290064059574, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5adc2c36-14a6-47ba-8065-699e914c5cac", "name": "7715ca32-ff8b-41d5-b13e-652d37d6fbba", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d47e11d8-d612-4fd1-8682-c3435b00d0fa"}}}]}, {"uuid": "30eb92bc-4c73-40a8-b189-220ec402e1a5", "name": "load_p1rlv13677_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9aa7e62-8974-4ef0-aa5a-bcd545245aea"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5adc2c36-14a6-47ba-8065-699e914c5cac"}}}}, {"uuid": "13171c16-3766-48a6-b85d-fce1b4c23608", "name": "f1180b47-ce6c-459c-83e7-24fe85daf4e6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6b7e05ca-5d8d-4687-9c91-c46be0e94393", "name": "ced260df-4a12-44dd-880b-4d67e0c60293", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "13171c16-3766-48a6-b85d-fce1b4c23608"}}}]}, {"uuid": "b60bbcc8-db1c-4b2c-9ab8-17791087b760", "name": "load_p1rlv13678_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32b75c61-4e97-4e21-a786-8aab7a2d88f8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6b7e05ca-5d8d-4687-9c91-c46be0e94393"}}}}, {"uuid": "b62f2251-d24d-45e7-980e-ef4d9b47a504", "name": "1c1f827a-7066-412b-bf61-608d040d4916_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "56ae25bf-98c2-4005-ac11-543cc9eddeb7", "name": "d22d54e4-5e52-4472-8bf7-9a78ff6df048", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b62f2251-d24d-45e7-980e-ef4d9b47a504"}}}]}, {"uuid": "a0329e2e-1fa6-46e3-824e-c7da00ff962b", "name": "load_p1rlv13678_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32b75c61-4e97-4e21-a786-8aab7a2d88f8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "56ae25bf-98c2-4005-ac11-543cc9eddeb7"}}}}, {"uuid": "1216f196-6d86-4e3b-bda0-7366a867f755", "name": "02fab3ec-855e-490e-896f-7a706d20c1d4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5877230897388055, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4388767979233367, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f958ad87-2a98-4e6a-a293-8057d8fe389f", "name": "91e84414-0314-4efb-aba4-d8fed00ee89e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1216f196-6d86-4e3b-bda0-7366a867f755"}}}]}, {"uuid": "73b7d0ef-ca91-438c-868f-4ce161d78b94", "name": "load_p1rlv13679_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "284bbc5d-bb49-404d-823e-08ec543c90b8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f958ad87-2a98-4e6a-a293-8057d8fe389f"}}}}, {"uuid": "97ce0ac1-19b9-4960-8f86-e49ce43b4fdd", "name": "15a4960a-ad64-43bb-8715-67624839e8bb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5877230897388055, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4388767979233367, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a345b66d-51c6-4718-92d2-1e66017171ec", "name": "646d7312-411e-4fa8-8089-802c3b8ac94a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "97ce0ac1-19b9-4960-8f86-e49ce43b4fdd"}}}]}, {"uuid": "f5ffe810-c070-4042-bd16-a1d1047e555d", "name": "load_p1rlv13679_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "284bbc5d-bb49-404d-823e-08ec543c90b8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a345b66d-51c6-4718-92d2-1e66017171ec"}}}}, {"uuid": "c8b1c45d-d4d0-4928-935c-3866c5267d73", "name": "fc9cbd12-67da-4ddf-9e17-a4cc9d3d7a39_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "90e84820-53f8-4ec5-ab30-c1b8adeba609", "name": "a6367165-e64e-4785-83c4-49e85d650317", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c8b1c45d-d4d0-4928-935c-3866c5267d73"}}}]}, {"uuid": "0fb1c0b4-f597-4755-9070-7a24b5f8b93a", "name": "load_p1rlv13680_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85b910cd-def8-41d8-ad47-3c074a54ad8d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "90e84820-53f8-4ec5-ab30-c1b8adeba609"}}}}, {"uuid": "24e8ad5a-5435-4bd3-a930-36188d2f4313", "name": "0a87ea87-5580-41e4-a52e-41639b7d996c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ea4d6a04-3fdf-4e82-baad-0269aed2b904", "name": "996cd32f-f05e-4470-b8d1-10acdbd6854d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "24e8ad5a-5435-4bd3-a930-36188d2f4313"}}}]}, {"uuid": "21437a63-b495-4b76-876c-e5f86f7be7fc", "name": "load_p1rlv13680_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85b910cd-def8-41d8-ad47-3c074a54ad8d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ea4d6a04-3fdf-4e82-baad-0269aed2b904"}}}}, {"uuid": "6632eb7e-bae8-4711-8280-ac3a0a991206", "name": "28893ff5-412e-40a3-a212-52e2782d34ef_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "000ac7b0-24c3-4950-972d-e20658228342", "name": "8afd517a-a595-4d9f-b888-4b98d003878a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6632eb7e-bae8-4711-8280-ac3a0a991206"}}}]}, {"uuid": "369fe88d-458f-495d-a6fc-e2299dcaa1d3", "name": "load_p1rlv13681_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60f08cde-51d3-4b51-9ab5-b61c8043950f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "000ac7b0-24c3-4950-972d-e20658228342"}}}}, {"uuid": "73ed9a9b-8b1c-4d72-997d-3b3f06174e72", "name": "d307541e-6390-420b-90bc-c354842c8c4e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ad96ba65-d3c8-4412-a032-176eab395487", "name": "6105ce88-9320-477f-b2d2-85e6dd5ad86d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "73ed9a9b-8b1c-4d72-997d-3b3f06174e72"}}}]}, {"uuid": "82b351e5-a3aa-47e2-9520-cc902c46a692", "name": "load_p1rlv13681_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60f08cde-51d3-4b51-9ab5-b61c8043950f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ad96ba65-d3c8-4412-a032-176eab395487"}}}}, {"uuid": "865ddcf7-98d3-41f6-bf38-defee83d97b8", "name": "7ed0c62d-bcff-4b32-a663-d21ae0bf8ac3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5757409771642927, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7652901499575055, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "059b3c81-83a8-4bb0-8f63-a8de9452fb9b", "name": "4fffba48-2ddb-4844-95b5-c2808665038f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "865ddcf7-98d3-41f6-bf38-defee83d97b8"}}}]}, {"uuid": "629d17c4-bebd-48c9-879e-0c0e033ca412", "name": "load_p1rlv13682_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a3c050c-cc0d-460e-af02-ce3421431474"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "059b3c81-83a8-4bb0-8f63-a8de9452fb9b"}}}}, {"uuid": "1295811e-de6a-44ad-a13e-dda7e4e2cf61", "name": "9152cc72-9051-4239-b8f0-9b3dc8e0a72a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5757409771642927, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7652901499575055, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "591fd267-9404-4294-ae61-8c65df29bcb9", "name": "330bb019-c54a-4ecb-a332-7035a124455b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1295811e-de6a-44ad-a13e-dda7e4e2cf61"}}}]}, {"uuid": "47422c8c-3417-4dac-9c86-ffc9609bda7c", "name": "load_p1rlv13682_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a3c050c-cc0d-460e-af02-ce3421431474"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "591fd267-9404-4294-ae61-8c65df29bcb9"}}}}, {"uuid": "0db7c061-169a-4013-b150-b5f93a5140e5", "name": "b70b337e-55a5-4def-a326-eaaf47f57728_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5877230897388055, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4388767979233367, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "872b1bac-ff07-4d30-adf6-317dd41a1de5", "name": "2675fd69-b097-4d9b-9475-e2f3719c7a70", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0db7c061-169a-4013-b150-b5f93a5140e5"}}}]}, {"uuid": "668da774-22b3-42e2-a6b1-0280c9816f6a", "name": "load_p1rlv13683_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "de45dc59-3e0a-4b33-8cf4-d5213b0140c1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "872b1bac-ff07-4d30-adf6-317dd41a1de5"}}}}, {"uuid": "0e2ad523-f99c-4929-8d16-91ef3629506b", "name": "07fbfeaa-dc3a-4b54-b01e-0afb2c1c0371_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5877230897388055, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4388767979233367, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "54c1eeed-950d-4379-b00d-847f964c7ac4", "name": "d63dc4c7-07a6-4451-b606-6641acdcc48a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0e2ad523-f99c-4929-8d16-91ef3629506b"}}}]}, {"uuid": "ee5e2946-2306-4eaa-af5e-901222eea510", "name": "load_p1rlv13683_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "de45dc59-3e0a-4b33-8cf4-d5213b0140c1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "54c1eeed-950d-4379-b00d-847f964c7ac4"}}}}, {"uuid": "aa9fa668-8b5c-4c16-aa75-31f5d381c321", "name": "be235377-0688-4d31-a2cf-c9e6c94bc6e7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5202593896091736, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6973445820856009, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c859be38-862f-42d2-8694-e366a9f2128c", "name": "84e237c2-c2a7-4aa4-b35b-8229b8b5a493", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aa9fa668-8b5c-4c16-aa75-31f5d381c321"}}}]}, {"uuid": "f5fe6a40-9cf3-4744-bef2-05e7f64a97fc", "name": "load_p1rlv13684_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ec49353-14d1-4917-83bc-ca62cd94bf30"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c859be38-862f-42d2-8694-e366a9f2128c"}}}}, {"uuid": "2cd83c37-2373-4eda-af9a-c268cdd40bba", "name": "4b4456a7-c3f4-4a2e-88af-a0635f507705_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5202593896091736, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6973445820856009, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d89384a1-0e1f-41bf-8082-168c05d69b38", "name": "45cc88fb-5813-44e0-b1f4-9cd14a9451bc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2cd83c37-2373-4eda-af9a-c268cdd40bba"}}}]}, {"uuid": "6397bd60-fbca-423c-aaae-fe883c0a045e", "name": "load_p1rlv13684_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ec49353-14d1-4917-83bc-ca62cd94bf30"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d89384a1-0e1f-41bf-8082-168c05d69b38"}}}}, {"uuid": "c1bedbde-cb3b-48cf-83a8-2820a7cbe371", "name": "efdbfcfc-3608-4192-8ee7-1f4bfb75171f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3a9035cd-3ef0-4eb6-a016-ddba363a86a7", "name": "b77753f9-7255-4fa0-8139-9968b8f1520b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c1bedbde-cb3b-48cf-83a8-2820a7cbe371"}}}]}, {"uuid": "19754d34-82fa-46dd-84ee-d2646d6b799d", "name": "load_p1rlv13685_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f777bc74-e6f3-4e80-bb72-0764964db21e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3a9035cd-3ef0-4eb6-a016-ddba363a86a7"}}}}, {"uuid": "71467a1e-1ede-47b9-9bfd-85c4bac34c8f", "name": "4704cf25-87d5-43f7-83d1-c6088b025dd4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "36f533fa-a479-4daa-b3e0-5a2c5dbb51c3", "name": "3006d40c-9556-418a-aab0-e2444e2207a5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "71467a1e-1ede-47b9-9bfd-85c4bac34c8f"}}}]}, {"uuid": "3eabe4a1-6c61-4686-922c-e3a0e40af83e", "name": "load_p1rlv13685_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f777bc74-e6f3-4e80-bb72-0764964db21e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "36f533fa-a479-4daa-b3e0-5a2c5dbb51c3"}}}}, {"uuid": "94e6fa50-42fc-41e9-9abb-201d8e23d94f", "name": "fa86f889-dfcb-41a6-8f73-d9d7d90bf208_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ebee099f-241a-4c7d-b75d-2058d800889d", "name": "a9495890-1185-489f-b8c4-26fb7b1d0232", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "94e6fa50-42fc-41e9-9abb-201d8e23d94f"}}}]}, {"uuid": "91bc007c-1af6-48a0-a5e6-d8f0d37d137e", "name": "load_p1rlv13686_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60fe0a16-aa4d-4fe8-9f39-81bfa13b505f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ebee099f-241a-4c7d-b75d-2058d800889d"}}}}, {"uuid": "1112faee-e8b7-4260-880a-43e211c9ced0", "name": "39a3bdc6-ca82-438b-b699-d645d3ca387a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c9a78a4-19b6-4b48-9b0f-f5d183778f42", "name": "c339dea3-5781-414f-9f68-233cf2e25740", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1112faee-e8b7-4260-880a-43e211c9ced0"}}}]}, {"uuid": "d3c9ea73-77eb-488a-b9c1-b52499a39dba", "name": "load_p1rlv13686_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60fe0a16-aa4d-4fe8-9f39-81bfa13b505f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c9a78a4-19b6-4b48-9b0f-f5d183778f42"}}}}, {"uuid": "0f1e6ac0-70aa-4af0-a939-10d6bcc816b0", "name": "94db7979-8999-44bf-bf37-2b918522fb47_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4786893203254163, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3666592754227633, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8de6b990-1453-4ed8-abf9-d39634ea2aee", "name": "dacc3adb-a90c-4aea-b34a-559baea1c165", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0f1e6ac0-70aa-4af0-a939-10d6bcc816b0"}}}]}, {"uuid": "62d4d493-6a6b-41cd-ba20-e0f18e875b39", "name": "load_p1rlv13687_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4671f981-e26e-4f26-9698-7f9068ce6dec"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8de6b990-1453-4ed8-abf9-d39634ea2aee"}}}}, {"uuid": "332f9759-59a9-4733-84d5-01ddeb74945d", "name": "ab8b8986-c290-4ceb-8151-476952ad0e4f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4786893203254163, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3666592754227633, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "df94fbb6-0cd0-4e7a-8a43-22c6ff208d97", "name": "bc05459c-41f7-465c-a4a3-e1c5fd8cec2a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "332f9759-59a9-4733-84d5-01ddeb74945d"}}}]}, {"uuid": "29645c13-d3d0-4b4c-bbbf-afd5222598a3", "name": "load_p1rlv13687_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4671f981-e26e-4f26-9698-7f9068ce6dec"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "df94fbb6-0cd0-4e7a-8a43-22c6ff208d97"}}}}, {"uuid": "bd4ddb24-8e29-4b96-af3b-96f25a7494de", "name": "1319ad49-c4e4-44ac-9f97-597c74220ab2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7344cd86-6533-4184-a373-c02ab9549fca", "name": "332dc737-3c56-4c9e-bef6-ea2937774ea8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bd4ddb24-8e29-4b96-af3b-96f25a7494de"}}}]}, {"uuid": "4e62be72-5efb-4974-b102-b27fd9db4d5a", "name": "load_p1rlv13689_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e5db11f-0418-4119-9c71-26619456fd7b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7344cd86-6533-4184-a373-c02ab9549fca"}}}}, {"uuid": "5f414c6b-8fd3-4126-bd2a-bb61f3c48abe", "name": "d83021b0-7f17-4b5c-b199-976f49090c11_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "efbe0b52-16e1-4632-9ca6-3f01d3a7c2f6", "name": "4ccaf277-0aec-4dce-bdd6-8036eab4f00f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5f414c6b-8fd3-4126-bd2a-bb61f3c48abe"}}}]}, {"uuid": "392ed64a-44d5-409a-bcb8-7b53d7cb16be", "name": "load_p1rlv13689_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e5db11f-0418-4119-9c71-26619456fd7b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "efbe0b52-16e1-4632-9ca6-3f01d3a7c2f6"}}}}, {"uuid": "3200f720-b710-45ce-9dcf-f6448fe8fb4f", "name": "6f5a230a-2bc8-448d-ad0c-ca40306ac670_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "63d99ad2-499f-4001-8c6b-02d3b68cf97a", "name": "57e7ef2c-f725-4c38-a0d1-37ad2dc3eecf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3200f720-b710-45ce-9dcf-f6448fe8fb4f"}}}]}, {"uuid": "9530d4ad-f493-4ae8-b3f2-3e303d647d75", "name": "load_p1rlv13690_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "71c26ca3-0d61-46b8-a95b-710e0b760b62"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "63d99ad2-499f-4001-8c6b-02d3b68cf97a"}}}}, {"uuid": "7823cc66-5ff2-4c20-ab5d-91512e9d2c41", "name": "833ab35f-38f3-4673-b957-be716b6dcec7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2e2346ec-1d8b-496c-8acb-0feed9154b43", "name": "b15f16e7-cad3-4f3e-ae5f-129f399a4890", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7823cc66-5ff2-4c20-ab5d-91512e9d2c41"}}}]}, {"uuid": "bf76abe8-4b18-41e3-af4e-b76279eb2699", "name": "load_p1rlv13690_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "71c26ca3-0d61-46b8-a95b-710e0b760b62"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2e2346ec-1d8b-496c-8acb-0feed9154b43"}}}}, {"uuid": "e1737a50-5fd7-4b33-870f-d5b087c76427", "name": "fb5a4aa2-45c2-4ab6-9c67-965f1b1d50cb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7ba0cafd-5471-4410-a509-d82014858abd", "name": "ac7f08f8-7179-400f-9966-1643b06fc540", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e1737a50-5fd7-4b33-870f-d5b087c76427"}}}]}, {"uuid": "4b3eeef6-2fdc-4483-9a15-7d8a4f1f2ed0", "name": "load_p1rlv13691_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "850df31b-ee95-4903-93b7-6e5911e8f8a0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7ba0cafd-5471-4410-a509-d82014858abd"}}}}, {"uuid": "2ae22984-622d-4a1d-85f5-ce7064c1ae74", "name": "3cc735fc-385d-43f0-a35a-333df4a3392b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "124668c6-413a-4b80-bdda-2c889f127fc4", "name": "18b11031-e37c-4533-a5ae-8f60821f73cd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2ae22984-622d-4a1d-85f5-ce7064c1ae74"}}}]}, {"uuid": "24ccb9aa-e453-4fad-a5c8-1e8a306ff1eb", "name": "load_p1rlv13691_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "850df31b-ee95-4903-93b7-6e5911e8f8a0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "124668c6-413a-4b80-bdda-2c889f127fc4"}}}}, {"uuid": "3df4c39e-8ae1-4947-b3bc-19df9c776026", "name": "f6f6fdb3-fe43-4c07-8b28-4962430c7165_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.1140699739098325, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.0691290550182753, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9644c026-329a-4a1f-998b-60ece9776419", "name": "1f5df881-3b77-4b4a-bd21-a995d244dd40", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3df4c39e-8ae1-4947-b3bc-19df9c776026"}}}]}, {"uuid": "92ded483-725f-40c6-84b3-98a6015cec71", "name": "load_p1rlv13692_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "091b545a-eb31-4bea-a0a6-5aa9c7a8397f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9644c026-329a-4a1f-998b-60ece9776419"}}}}, {"uuid": "d509bf1b-6112-4ef3-8154-002006554632", "name": "8079b172-9551-4da3-afd7-57c2a2d1d119_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.1140699739098325, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.0691290550182753, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "272b06f6-e51d-4f01-8e44-3e9511586061", "name": "f002eb9c-8fd9-40ef-bda6-b972d6ca4b2b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d509bf1b-6112-4ef3-8154-002006554632"}}}]}, {"uuid": "e1bfcb4c-83c9-4e63-a718-ede158d8b3a9", "name": "load_p1rlv13692_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "091b545a-eb31-4bea-a0a6-5aa9c7a8397f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "272b06f6-e51d-4f01-8e44-3e9511586061"}}}}, {"uuid": "f549d4ee-7d2c-458a-8865-413d3613ff12", "name": "eb9d67ed-dbaf-4e6a-aa5f-36a91f666e0b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e41d8d1c-8dd4-4bf2-a16c-50fca8aa045e", "name": "2830747a-ac37-40dc-8c02-935d3b9912ec", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f549d4ee-7d2c-458a-8865-413d3613ff12"}}}]}, {"uuid": "d55f90b8-e894-4da7-860a-3958326632e3", "name": "load_p1rlv13693_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5815b75-1226-4221-9bcb-bc75ce85fa17"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e41d8d1c-8dd4-4bf2-a16c-50fca8aa045e"}}}}, {"uuid": "476a69e1-a9e0-4928-b7f3-552cc90bf303", "name": "38c60878-bd82-4df7-848f-9985598f5fe7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "655ebaf4-0818-4331-ae7d-7146bedafebc", "name": "1ab0c66e-95fd-4115-80fd-a9db9b12c908", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "476a69e1-a9e0-4928-b7f3-552cc90bf303"}}}]}, {"uuid": "149e6a50-bc4c-437f-9e56-86146effe61a", "name": "load_p1rlv13693_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5815b75-1226-4221-9bcb-bc75ce85fa17"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "655ebaf4-0818-4331-ae7d-7146bedafebc"}}}}, {"uuid": "a62dc22d-1f8d-46b2-8556-ca0dc332c559", "name": "8e6a59bb-fad2-4318-9066-580c5077702b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8bd92f03-a0f4-48ce-9b3d-09bffcd2412d", "name": "6557eb3f-9fea-4473-a24d-7b4ce0e44fc6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a62dc22d-1f8d-46b2-8556-ca0dc332c559"}}}]}, {"uuid": "4a37d94a-f80d-47e0-b65b-01e2960318e1", "name": "load_p1rlv13694_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1de2ebf2-3207-4bf7-9702-4c729d99a6cf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8bd92f03-a0f4-48ce-9b3d-09bffcd2412d"}}}}, {"uuid": "71d8bcb0-42da-4718-bf2d-e7d363ead5c4", "name": "a96590fd-adbb-41d9-a01a-98631e5a4933_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aa9a819d-caee-485b-88bf-f4ae3727b769", "name": "b739da1c-6f92-41cb-81d2-12f6cbf701d1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "71d8bcb0-42da-4718-bf2d-e7d363ead5c4"}}}]}, {"uuid": "9b9c8591-0453-4c68-bf4a-37c70b29ae2f", "name": "load_p1rlv13694_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1de2ebf2-3207-4bf7-9702-4c729d99a6cf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aa9a819d-caee-485b-88bf-f4ae3727b769"}}}}, {"uuid": "09c4d5f1-71c4-469b-8603-f1b25c00d631", "name": "4c485e30-41bd-4083-8717-dbc40101c2f3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.17188390355877, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.554870220420769, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a3ee682c-b1c7-44c4-bff6-a4d8acad378c", "name": "d6029c33-cd14-49e9-888f-548ed4366560", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "09c4d5f1-71c4-469b-8603-f1b25c00d631"}}}]}, {"uuid": "4f0a34ae-c8fc-44bd-9c7c-c804db865c3b", "name": "load_p1rlv13695_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d73963d7-acf4-48b3-8e54-6ee9f403d36f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a3ee682c-b1c7-44c4-bff6-a4d8acad378c"}}}}, {"uuid": "a14f6598-dcf3-4222-aff9-03aa785c3232", "name": "7324e4d5-eff6-4b91-8842-ad45bb36e2fb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.17188390355877, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.554870220420769, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "38fd2fc8-af2c-4375-bb14-2735753fd5ba", "name": "01c38178-5c60-4a27-b3b1-b8c4762989e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a14f6598-dcf3-4222-aff9-03aa785c3232"}}}]}, {"uuid": "ae6c0fd0-d614-4c0f-90ef-5fc0b3295f59", "name": "load_p1rlv13695_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d73963d7-acf4-48b3-8e54-6ee9f403d36f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "38fd2fc8-af2c-4375-bb14-2735753fd5ba"}}}}, {"uuid": "5eb73892-27e2-4054-8588-b0de1be5cdee", "name": "a3430b8f-8606-44be-b936-cc51b83628d6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.170918611307458, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.575413421893771, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e031df21-cbfa-4b1e-8a85-d904674671a8", "name": "a35ed688-1237-412d-8710-5425de3c9f82", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5eb73892-27e2-4054-8588-b0de1be5cdee"}}}]}, {"uuid": "cab9456a-bb12-404e-a3a4-c1d4a783098f", "name": "load_p1rlv13696_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f92273c9-90b8-4819-b036-9d69afb5aed6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e031df21-cbfa-4b1e-8a85-d904674671a8"}}}}, {"uuid": "ae2a96b5-8402-4705-b3ef-47eb2956246d", "name": "aebf8306-45df-47e3-8094-e02d25e14710_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.170918611307458, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.575413421893771, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "545bb6e9-937c-4335-8831-35cbfa5fc324", "name": "b7f7404f-11dd-4e22-8878-ad6ae3c5a2ca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ae2a96b5-8402-4705-b3ef-47eb2956246d"}}}]}, {"uuid": "0125f75c-efd6-4957-8ac0-1e8d533a3b87", "name": "load_p1rlv13696_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f92273c9-90b8-4819-b036-9d69afb5aed6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "545bb6e9-937c-4335-8831-35cbfa5fc324"}}}}, {"uuid": "483eaae2-214c-421b-b39c-b03f28d630fe", "name": "6bfb24b7-09c7-4f6c-a33c-d67aea19d82a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2370181650987906, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5806603708512078, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6e1fad86-4bfd-4d5f-8057-b77f7ec6b87f", "name": "6872893f-2e86-4889-9cf0-3945d3f9b966", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "483eaae2-214c-421b-b39c-b03f28d630fe"}}}]}, {"uuid": "fe5131a4-e117-4bfc-8606-a1410341e010", "name": "load_p1rlv13697_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c808261e-a49e-4954-bdc4-a8b63d0ee25b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6e1fad86-4bfd-4d5f-8057-b77f7ec6b87f"}}}}, {"uuid": "8a9fb659-c0b2-49a0-9cbc-4c1489f3ddbd", "name": "e2f294d7-0cb7-467e-89cf-090a4f35106e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2370181650987906, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5806603708512078, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b6121fa9-05bb-4af6-ace7-6219736b9224", "name": "e6ad07be-0efa-4e50-8ae6-c3e29b1d6a86", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a9fb659-c0b2-49a0-9cbc-4c1489f3ddbd"}}}]}, {"uuid": "05f1dfea-f98f-4ad7-b5f1-125332718265", "name": "load_p1rlv13697_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c808261e-a49e-4954-bdc4-a8b63d0ee25b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b6121fa9-05bb-4af6-ace7-6219736b9224"}}}}, {"uuid": "994053b2-2dcd-4e45-99c1-0143b8d3a3f4", "name": "9633f640-6a82-4afc-8062-185d65b30729_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cac11212-2c59-40b9-a2a9-c754625bb9fe", "name": "38b59a81-9591-40cb-ab35-f1578767f4a6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "994053b2-2dcd-4e45-99c1-0143b8d3a3f4"}}}]}, {"uuid": "cf7355e4-9d2e-4ae6-9384-4cbac3892452", "name": "load_p1rlv13698_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3839c291-3f45-46c3-973f-6a9615fcf81b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cac11212-2c59-40b9-a2a9-c754625bb9fe"}}}}, {"uuid": "48520c39-4eb5-43e5-86ce-ee13fd69508b", "name": "879b2b6d-5a7e-43a3-b01d-cf1172000d71_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1a354e32-b9f7-48a2-9d67-16babb502626", "name": "62fd14d7-3f51-4606-8237-98874714c9e6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "48520c39-4eb5-43e5-86ce-ee13fd69508b"}}}]}, {"uuid": "3be1397a-8a05-4668-9b09-656b568aab4b", "name": "load_p1rlv13698_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3839c291-3f45-46c3-973f-6a9615fcf81b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1a354e32-b9f7-48a2-9d67-16babb502626"}}}}, {"uuid": "29c3eb53-e8e6-434d-b8b9-b5d0eeeef957", "name": "f2b3afb2-d9d1-4df0-bc47-cb542a352e1a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9800785435301127, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2597629929517743, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "efea7d55-d9c3-40d8-9974-1ec710094411", "name": "fdc6bcae-ed53-44fc-a78d-8e226ddf0975", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "29c3eb53-e8e6-434d-b8b9-b5d0eeeef957"}}}]}, {"uuid": "78ea114e-84ee-4615-baf9-4817aefbf5b8", "name": "load_p1rlv13700_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ecf9ee9-2a3c-431b-84c8-02c7c7aaacb1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "efea7d55-d9c3-40d8-9974-1ec710094411"}}}}, {"uuid": "3ac6bc75-465b-42b3-852e-eeb5e2d1037e", "name": "501c5d20-904e-4849-b8b3-9edea9c96d6e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9800785435301127, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2597629929517743, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "396a415b-295f-4d6d-962d-c35b69dbfb00", "name": "6233a0aa-0d77-4a61-a4d0-eea1dbb1ac97", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3ac6bc75-465b-42b3-852e-eeb5e2d1037e"}}}]}, {"uuid": "e240f08b-a2bd-43ef-9bc3-418489941ef9", "name": "load_p1rlv13700_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ecf9ee9-2a3c-431b-84c8-02c7c7aaacb1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "396a415b-295f-4d6d-962d-c35b69dbfb00"}}}}, {"uuid": "c7596c6f-33bf-4ce8-94b7-ce8450625e3e", "name": "7fa0faeb-9e91-41c9-a0ee-8f12863cd6ec_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.547211686956079, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18814377021524833, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e3af9236-7fa2-4281-89b0-939b2cc9f155", "name": "dc89826e-cbd4-4e83-a5dd-8763bef64cb9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c7596c6f-33bf-4ce8-94b7-ce8450625e3e"}}}]}, {"uuid": "eb4e4727-b4f0-46ec-826a-dbb1737983cb", "name": "load_p1rlv13701_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa7a324e-d367-49a5-820a-b18e72243265"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e3af9236-7fa2-4281-89b0-939b2cc9f155"}}}}, {"uuid": "64f28cd5-6b3a-49ee-b88b-876bf0d5f347", "name": "a33c02eb-f545-461b-bc95-84d092c7914e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.547211686956079, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18814377021524833, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "83710f86-c125-4c89-92ad-3a6ded5b40b9", "name": "e727b800-0e89-42c7-8c25-e590764f428a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "64f28cd5-6b3a-49ee-b88b-876bf0d5f347"}}}]}, {"uuid": "deae30e2-4d1e-4e45-92b3-0d11ee422fcb", "name": "load_p1rlv13701_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa7a324e-d367-49a5-820a-b18e72243265"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "83710f86-c125-4c89-92ad-3a6ded5b40b9"}}}}, {"uuid": "700b9b2f-11c3-4d94-b9b7-14206f86098b", "name": "ec7828bd-32bf-4859-b88f-9d00dbada00e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "13bab12d-d6b7-45e9-ba69-182dcf8a0a9b", "name": "741e51a1-eebf-437e-91ba-84cc74e720fc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "700b9b2f-11c3-4d94-b9b7-14206f86098b"}}}]}, {"uuid": "6a27aee9-62a0-48e0-a446-8b3d4f3219e7", "name": "load_p1rlv13702_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fe3c958-296f-4b51-8b2b-74bb34ddb5a6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "13bab12d-d6b7-45e9-ba69-182dcf8a0a9b"}}}}, {"uuid": "a9754e34-ddf1-4994-8ce0-4913a3e58681", "name": "b0090678-8998-4d48-a463-dd05e6730437_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "936f4ea1-214f-4414-8b34-6ce0bf9879d7", "name": "54c22d49-2d81-4419-89f9-1ad89c5904de", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a9754e34-ddf1-4994-8ce0-4913a3e58681"}}}]}, {"uuid": "b405cc7f-aac6-4979-b0e8-4bc67aaf6e2e", "name": "load_p1rlv13702_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fe3c958-296f-4b51-8b2b-74bb34ddb5a6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "936f4ea1-214f-4414-8b34-6ce0bf9879d7"}}}}, {"uuid": "ad6f3996-5250-4903-900c-98cc80721468", "name": "e8a90a05-9c86-433f-a9ad-9ad3bb2f8b82_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2769071780208345, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4029118207034132, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "95c019d8-e7bf-4afd-a080-a6f621649229", "name": "05eeeca4-83c7-4501-b26c-d31da230df29", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ad6f3996-5250-4903-900c-98cc80721468"}}}]}, {"uuid": "3dab6f65-4632-4a3b-b353-50d00476b9c7", "name": "load_p1rlv13703_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9efacf5-5b96-4670-b6f1-dc398485cde9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "95c019d8-e7bf-4afd-a080-a6f621649229"}}}}, {"uuid": "97c46857-975d-412a-a4e0-5809874f5c16", "name": "ecb942cd-9b32-4043-b0e8-dc7a236faee7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2769071780208345, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4029118207034132, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f5e1e662-9c2f-48a5-85fb-d172280f7787", "name": "a31d2e6f-e64f-4b3d-b7d7-d3bb98c08c73", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "97c46857-975d-412a-a4e0-5809874f5c16"}}}]}, {"uuid": "bcb30f07-f390-431a-9ff8-0cde94b4035a", "name": "load_p1rlv13703_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9efacf5-5b96-4670-b6f1-dc398485cde9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f5e1e662-9c2f-48a5-85fb-d172280f7787"}}}}, {"uuid": "67e20fc8-11d1-4dc4-b232-49a9104fdd94", "name": "ddfc1f7d-1036-4cfa-9a48-fa1ba44fd782_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5d75438e-9f5d-481a-973d-ae138fa0337f", "name": "5fc81374-3427-4e96-8835-d0eb39e298a4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "67e20fc8-11d1-4dc4-b232-49a9104fdd94"}}}]}, {"uuid": "3b180503-e355-4f5c-9e1e-c2dca49a1d38", "name": "load_p1rlv13705_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f409299-5ac0-4f31-a217-d0aef7fbc4d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5d75438e-9f5d-481a-973d-ae138fa0337f"}}}}, {"uuid": "4b785ece-1a3a-4873-93a0-aaff723e54ea", "name": "26668d8a-2dbe-4359-a6bb-451d9a76228c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0b47fcab-65b9-4a82-b1bb-a2a21beb6138", "name": "903b60ff-3b21-4883-8b18-faae551c3d75", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4b785ece-1a3a-4873-93a0-aaff723e54ea"}}}]}, {"uuid": "284635fd-7a8a-4cf2-b20e-40b17b78ba7b", "name": "load_p1rlv13705_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f409299-5ac0-4f31-a217-d0aef7fbc4d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0b47fcab-65b9-4a82-b1bb-a2a21beb6138"}}}}, {"uuid": "c19162f1-9baa-4f3a-8e29-091896a65a63", "name": "44433df7-721c-49f3-9d4a-3f79a6898b62_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "49ba3689-a5c8-4f05-88d4-29a5f9a32264", "name": "bc6dd17f-97b0-46bb-b18d-a96ac1e78365", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c19162f1-9baa-4f3a-8e29-091896a65a63"}}}]}, {"uuid": "6ffcabfc-6189-4923-9459-f810143a516a", "name": "load_p1rlv13706_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e60fc98a-9c1d-4975-a9b9-e37271b4ac81"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "49ba3689-a5c8-4f05-88d4-29a5f9a32264"}}}}, {"uuid": "43c584f4-0f3c-4289-bee3-b8198dccaf4d", "name": "4807c297-4619-4dbb-ac3a-93b5cd05776e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ee8dd868-18b6-4d0f-881b-f0cc44f0ca24", "name": "d7cfc5db-df8b-4faa-ab3e-40d38ee914fa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "43c584f4-0f3c-4289-bee3-b8198dccaf4d"}}}]}, {"uuid": "bc3cf296-500e-48df-8860-073864e4dd2b", "name": "load_p1rlv13706_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e60fc98a-9c1d-4975-a9b9-e37271b4ac81"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ee8dd868-18b6-4d0f-881b-f0cc44f0ca24"}}}}, {"uuid": "6413e194-03e5-48c7-88a6-50f535f3a72a", "name": "ff48c4d2-8b8a-42b7-8b13-547e96dc9bd6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1f78e963-e9df-4f71-b59b-b7020b109583", "name": "7e30d6c4-12cd-4aab-8b47-451df08c4733", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6413e194-03e5-48c7-88a6-50f535f3a72a"}}}]}, {"uuid": "e95cd4c6-356c-4db2-be42-22421b873317", "name": "load_p1rlv13707_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "286623b3-af08-4a60-896a-1f5b85fe04a5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1f78e963-e9df-4f71-b59b-b7020b109583"}}}}, {"uuid": "3366db9e-3cf3-4151-8361-83b441a1f30e", "name": "22f79fb6-2b63-4702-ab85-effb7f238529_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a0851e07-4737-49ff-84ad-daa6bc98b911", "name": "694b01b0-174c-47ff-8dd6-2ba5e1fe9d3d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3366db9e-3cf3-4151-8361-83b441a1f30e"}}}]}, {"uuid": "56d76667-0cdd-48ef-a18b-ed51d5d65d1e", "name": "load_p1rlv13707_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "286623b3-af08-4a60-896a-1f5b85fe04a5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a0851e07-4737-49ff-84ad-daa6bc98b911"}}}}, {"uuid": "75952726-7480-4eb3-8fca-e410a5609a32", "name": "1171d848-94aa-4d3f-85e2-f6b2a083abf4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "66c585a7-9929-4d9e-b2c0-4038ef131727", "name": "97b55cae-aa0a-4c34-987e-efdb2ef1e497", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "75952726-7480-4eb3-8fca-e410a5609a32"}}}]}, {"uuid": "49afa33d-2db8-4c25-baf0-db76d22a5b78", "name": "load_p1rlv13708_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a230534-6927-4af8-ba54-6ab4c9c32d21"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "66c585a7-9929-4d9e-b2c0-4038ef131727"}}}}, {"uuid": "6f76b578-9e6c-4143-9fa1-0a9d00e81721", "name": "58d582ca-d92e-49a9-afa0-3d49ad5ddf68_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "75a5498f-0a83-4d9a-a17e-bdde0fccc40d", "name": "3842aa62-58e8-4549-b39a-ef1b378b39d4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6f76b578-9e6c-4143-9fa1-0a9d00e81721"}}}]}, {"uuid": "e17a4e5a-76ab-4e2b-9deb-0ddc2436202c", "name": "load_p1rlv13708_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a230534-6927-4af8-ba54-6ab4c9c32d21"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "75a5498f-0a83-4d9a-a17e-bdde0fccc40d"}}}}, {"uuid": "b23ca2b3-f01b-4a70-9c20-3ef8d65883bc", "name": "92063d80-548f-4737-aba3-d38c65b55fda_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "58ee1ba5-d4cd-483f-b539-6f48b5664106", "name": "620fd620-3af1-4383-9614-c5fa3611b9b6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b23ca2b3-f01b-4a70-9c20-3ef8d65883bc"}}}]}, {"uuid": "6bd8147e-4da1-41f0-ab34-81bf5be88280", "name": "load_p1rlv13711_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2bfaa34-267c-4dfd-8b6d-4ab444ac4048"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "58ee1ba5-d4cd-483f-b539-6f48b5664106"}}}}, {"uuid": "b216556a-58a2-4ff4-b485-d2e41df9d5c5", "name": "46df789e-0b71-4086-9338-f9f9abed9eea_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6508feb2-672c-4f09-bedf-352defe69273", "name": "8a7044d2-9623-4090-9535-7b77ebdfd4e1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b216556a-58a2-4ff4-b485-d2e41df9d5c5"}}}]}, {"uuid": "29ab3c31-513d-4ba8-92a0-46a0df8c64dc", "name": "load_p1rlv13711_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2bfaa34-267c-4dfd-8b6d-4ab444ac4048"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6508feb2-672c-4f09-bedf-352defe69273"}}}}, {"uuid": "6418ab48-9339-4497-855a-b597731a1243", "name": "cc53d833-c02e-462e-aaa6-5805e0b3df3b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7545306166330135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0868234997236217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "146c8f5e-86e7-4955-9415-724b425e7d92", "name": "b490587e-dcfa-48bf-bb38-9da514ff2a94", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6418ab48-9339-4497-855a-b597731a1243"}}}]}, {"uuid": "ff3b22fc-25ef-4ea2-ad20-a01769dd6228", "name": "load_p1rlv13712_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ab8bce-7c02-4c7b-962e-3fb44a3ab7a9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "146c8f5e-86e7-4955-9415-724b425e7d92"}}}}, {"uuid": "97ab516e-1b75-4db4-a02f-2a3e534364ed", "name": "edbd1e33-e791-41c6-adbf-15ff89ddf2f5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7545306166330135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0868234997236217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4f328d12-489d-4a0a-ac22-c15f688ebf38", "name": "cf4b514d-e94c-426f-ac7e-479f28cfb2ed", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "97ab516e-1b75-4db4-a02f-2a3e534364ed"}}}]}, {"uuid": "6bd90a3f-7030-4ebd-8435-2deaa7b3287c", "name": "load_p1rlv13712_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ab8bce-7c02-4c7b-962e-3fb44a3ab7a9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4f328d12-489d-4a0a-ac22-c15f688ebf38"}}}}, {"uuid": "aa2897bb-6c94-4c97-beed-05beeab0409b", "name": "7eb4941e-aab2-4b82-97d4-e5a1bea33332_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fd3fa0fb-eefc-44ed-bd10-dbc69cc69dbd", "name": "409fecca-9d80-4bfd-a225-8e9f1fa11b15", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aa2897bb-6c94-4c97-beed-05beeab0409b"}}}]}, {"uuid": "01e08a61-f12d-44e2-97f7-d9d92ef0dd55", "name": "load_p1rlv13713_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee766a99-bb6f-4d5c-8513-9d462103f6fc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fd3fa0fb-eefc-44ed-bd10-dbc69cc69dbd"}}}}, {"uuid": "72227943-9753-4764-89fd-9a52b2ff60b7", "name": "992e2843-abba-4520-b23a-1ae2deee57db_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c853f8ef-2cf1-4a41-8fb3-40148f6182d7", "name": "e07790a4-62ba-4aad-9b20-dee50a745a9d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72227943-9753-4764-89fd-9a52b2ff60b7"}}}]}, {"uuid": "d6d84b9a-453c-41d6-a1fc-e90bfc7c4af3", "name": "load_p1rlv13713_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee766a99-bb6f-4d5c-8513-9d462103f6fc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c853f8ef-2cf1-4a41-8fb3-40148f6182d7"}}}}, {"uuid": "754509b2-e93c-4cc1-ba8e-8f881a1b87e6", "name": "fcfdc003-f539-4d06-97f6-74b531454884_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9972586284721718, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5405993695804993, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8e3a8735-5c81-4955-ade7-ef788305f464", "name": "d85f1cf8-8756-4671-afc2-58fc47a83939", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "754509b2-e93c-4cc1-ba8e-8f881a1b87e6"}}}]}, {"uuid": "4618bcd0-4a49-42cb-a947-1ad974ae77c8", "name": "load_p1rlv13714_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17936036-1191-4f91-bc12-2298db7b77e3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8e3a8735-5c81-4955-ade7-ef788305f464"}}}}, {"uuid": "b47fcbac-90fa-4e88-97c5-2a030255e0c9", "name": "7d7b8d24-c368-427a-a6c5-39287240dca0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9972586284721718, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5405993695804993, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "98e26e6f-9bb9-4e70-8144-92a64d3fff47", "name": "be31ff26-26d7-4011-b6e4-9a2d9c7656d3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b47fcbac-90fa-4e88-97c5-2a030255e0c9"}}}]}, {"uuid": "6a9508d2-1734-48c3-8444-79bb54072e1b", "name": "load_p1rlv13714_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17936036-1191-4f91-bc12-2298db7b77e3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "98e26e6f-9bb9-4e70-8144-92a64d3fff47"}}}}, {"uuid": "9e151eb7-5f81-440f-974d-fe976df01299", "name": "1d91d7eb-1e63-4f9f-b435-1197599db6d1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "57633dc2-dcd6-4729-a316-4e096ed1f292", "name": "36e71770-34f7-46bb-afd0-ed2986df6ca6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9e151eb7-5f81-440f-974d-fe976df01299"}}}]}, {"uuid": "c812a679-890c-4d0f-98d9-0d1f7d45f99d", "name": "load_p1rlv13715_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a822fdb0-b531-49b0-89da-b517e5ae6e3a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "57633dc2-dcd6-4729-a316-4e096ed1f292"}}}}, {"uuid": "92649058-d744-41bd-91d4-969ee02e3557", "name": "71d0b39e-c5df-4efb-b9d0-b7bb3e2d3f60_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f2dfe100-e76c-4b08-ab10-7eafc439ced1", "name": "d7fb2e79-b36a-4da1-9450-e76fda612f21", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "92649058-d744-41bd-91d4-969ee02e3557"}}}]}, {"uuid": "5523e36f-b164-4cd1-b47f-790f9d2080f0", "name": "load_p1rlv13715_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a822fdb0-b531-49b0-89da-b517e5ae6e3a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f2dfe100-e76c-4b08-ab10-7eafc439ced1"}}}}, {"uuid": "6fcedadc-5687-4d32-801f-41ea8517173a", "name": "b9c70ccf-2ea5-4a70-8329-c5a5c75154eb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0fb544c1-e897-425d-9c92-9a04c78144f4", "name": "5b8ab658-643d-4572-9f87-1dfc56ee539d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6fcedadc-5687-4d32-801f-41ea8517173a"}}}]}, {"uuid": "9373a3d8-431a-4e5b-bc97-72b35793721a", "name": "load_p1rlv13716_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb3b4207-12ad-46e6-b4de-59149a46f8a1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0fb544c1-e897-425d-9c92-9a04c78144f4"}}}}, {"uuid": "6c990dc3-9aae-434f-be73-936224343e7d", "name": "a1327074-a0dd-4963-980d-8c1955fa3f43_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "07876a8a-aef7-4bb8-83b4-1ce723379caa", "name": "e9b74712-8026-4896-b0d9-748f9f85c33b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c990dc3-9aae-434f-be73-936224343e7d"}}}]}, {"uuid": "0d8ddad1-6cb5-490c-a4a7-08840429a56d", "name": "load_p1rlv13716_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb3b4207-12ad-46e6-b4de-59149a46f8a1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "07876a8a-aef7-4bb8-83b4-1ce723379caa"}}}}, {"uuid": "7b4d227c-71c5-44be-a753-27a2e2d3c822", "name": "d7ba2655-5d70-485e-a3e2-d7dab97b4ffb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "083c693f-7451-4a82-98a6-fd33ae600b7a", "name": "254e231c-54d2-4360-84e4-cb99d595c499", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b4d227c-71c5-44be-a753-27a2e2d3c822"}}}]}, {"uuid": "40c3c225-3dc3-4e2a-8cb6-a855fc0d6d40", "name": "load_p1rlv13717_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdbfe616-f51f-416a-94ce-6e676d300226"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "083c693f-7451-4a82-98a6-fd33ae600b7a"}}}}, {"uuid": "5fd7b8b0-61ac-48cd-ab38-7094e02b1c97", "name": "fd0f1747-45ce-40d0-b4b5-2f8db2d3681c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d98c18a0-87e8-428f-a555-1a94776ba879", "name": "db0912c1-87b2-4d95-b1f8-28ada67f3122", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5fd7b8b0-61ac-48cd-ab38-7094e02b1c97"}}}]}, {"uuid": "0015d220-ad70-47b2-b3a3-4672d57385af", "name": "load_p1rlv13717_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdbfe616-f51f-416a-94ce-6e676d300226"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d98c18a0-87e8-428f-a555-1a94776ba879"}}}}, {"uuid": "25542898-6b2c-4f16-af7d-d7b082c9a12a", "name": "385d9c16-4654-417c-b777-7aa08f6a082a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6027984746974515, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12293402966163972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4632ff26-1435-4900-8c24-064f89444d78", "name": "ae548c79-9b0f-4aec-bbd3-caf8815c145e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "25542898-6b2c-4f16-af7d-d7b082c9a12a"}}}]}, {"uuid": "e97f8a95-0a85-4426-a5d7-bf700b901a92", "name": "load_p1rlv13719_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44aa3f37-e0db-4050-b47f-ac14b7fa6534"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4632ff26-1435-4900-8c24-064f89444d78"}}}}, {"uuid": "0ead7666-1788-4c58-9475-78f07dbfb2c7", "name": "ad3f2d2e-c3ce-4ceb-b06e-a313b53c404b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6027984746974515, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12293402966163972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4f684ec0-59a6-4e94-8609-46ee2f369b86", "name": "93bf93cf-51e3-4a04-bcd7-07e3527deb4e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0ead7666-1788-4c58-9475-78f07dbfb2c7"}}}]}, {"uuid": "0c2ba3a8-52db-4453-98c3-67ef3943039d", "name": "load_p1rlv13719_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44aa3f37-e0db-4050-b47f-ac14b7fa6534"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4f684ec0-59a6-4e94-8609-46ee2f369b86"}}}}, {"uuid": "065ac14e-ad43-4f8a-83bc-458d5a376d9e", "name": "2cfb0ada-7713-4150-b59c-1764af325937_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.693271865954936, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.115673740909077, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f032b135-567f-41e1-8f02-30eeb30cae74", "name": "2cfb0ada-7713-4150-b59c-1764af325937_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.693271865954936, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.115673740909077, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f66981dc-9a7f-4d48-9c9a-d014312e2040", "name": "2cfb0ada-7713-4150-b59c-1764af325937_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.693271865954936, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.115673740909077, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8b79ad69-4cec-4070-b217-a724f6a87163", "name": "18df2ab4-f102-49e3-b6d5-46c286393f54", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "065ac14e-ad43-4f8a-83bc-458d5a376d9e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f032b135-567f-41e1-8f02-30eeb30cae74"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f66981dc-9a7f-4d48-9c9a-d014312e2040"}}}]}, {"uuid": "40539eb5-04a1-47e8-a33d-f250c4efcda6", "name": "load_p1rlv13720", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fe1a5da7-bdac-46a6-ab32-addc4f02a296"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8b79ad69-4cec-4070-b217-a724f6a87163"}}}}, {"uuid": "a4bea439-76cd-4468-a365-8b99869e18b0", "name": "ff334ece-0414-4a5d-978d-16814908ce78_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.498014754859445, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0be10e40-addc-44a0-95b8-17c2667d64b0", "name": "865d928c-09a8-4aa7-89d9-5402b1f98597", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a4bea439-76cd-4468-a365-8b99869e18b0"}}}]}, {"uuid": "4532d3a3-933d-4350-bf56-5f09d7e02f59", "name": "load_p1rlv13721_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6097c903-70fc-4635-a66c-fee2243ba545"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0be10e40-addc-44a0-95b8-17c2667d64b0"}}}}, {"uuid": "cf061642-a570-42d7-b6a1-bda4f7bf11ad", "name": "376a1a9f-7a87-4dc5-8f2b-c2e69d99aedb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.498014754859445, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2f0f3560-d5e9-45dc-8fa1-57c4492d0228", "name": "b2f84c5f-390e-4a57-b294-a258c93c856b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cf061642-a570-42d7-b6a1-bda4f7bf11ad"}}}]}, {"uuid": "e2a2af36-b6fb-44d1-9b8d-8a541a55cbc9", "name": "load_p1rlv13721_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6097c903-70fc-4635-a66c-fee2243ba545"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2f0f3560-d5e9-45dc-8fa1-57c4492d0228"}}}}, {"uuid": "cbaebd38-060c-47f8-a31d-82317d5498d4", "name": "8400bf58-7f39-43b7-8782-b26400ae2afa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0772156037646567, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.01984596164170695, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "adb63022-7bff-420c-9630-a71369c1173d", "name": "93f5ad57-9582-470d-b478-7cf205431bde", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cbaebd38-060c-47f8-a31d-82317d5498d4"}}}]}, {"uuid": "5913b235-7f23-44d3-9bed-4855db1ffb03", "name": "load_p1rlv13723_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0f1846b-2515-48ef-9241-0276932f8e75"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "adb63022-7bff-420c-9630-a71369c1173d"}}}}, {"uuid": "63a5c690-9991-4d51-b11e-65fa0936739c", "name": "e646f638-eead-4a67-a015-aabf77b9dfdd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0772156037646567, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.01984596164170695, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a4afb26a-6c9f-4511-b59f-42dc4d6fc4b6", "name": "fbda14f5-a977-4076-bac2-a87ecd3c5a6b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "63a5c690-9991-4d51-b11e-65fa0936739c"}}}]}, {"uuid": "4978d1b9-2594-4bf0-af8d-9600ad7d7685", "name": "load_p1rlv13723_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0f1846b-2515-48ef-9241-0276932f8e75"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a4afb26a-6c9f-4511-b59f-42dc4d6fc4b6"}}}}, {"uuid": "3b053fe4-7517-4e8b-a5db-7c0200c5301f", "name": "09d2550e-5249-4897-86b2-15f06064b6df_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6277722044378486, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6969686665668667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7370b0bd-80cd-433b-9192-bc43c5e1a7be", "name": "7c3ad141-20bd-4f8a-ae12-33ad20556a42", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3b053fe4-7517-4e8b-a5db-7c0200c5301f"}}}]}, {"uuid": "a45714a0-7b14-4206-955f-80f8c450db3d", "name": "load_p1rlv13724_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "457c6c9d-5020-4cf3-9c1e-c36012a619d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7370b0bd-80cd-433b-9192-bc43c5e1a7be"}}}}, {"uuid": "58a76492-a584-4280-918a-07b715d387df", "name": "7b59b86e-a70a-42ac-a0ac-c35549727ff6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6277722044378486, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6969686665668667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a143659c-ad8d-4069-a8e5-cb7f495a2ab8", "name": "ddac1d04-e4a4-4508-b483-e46fc85dcad2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58a76492-a584-4280-918a-07b715d387df"}}}]}, {"uuid": "2f81c172-7861-4ac1-8635-9c7b7be1eea0", "name": "load_p1rlv13724_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "457c6c9d-5020-4cf3-9c1e-c36012a619d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a143659c-ad8d-4069-a8e5-cb7f495a2ab8"}}}}, {"uuid": "4f7e210b-8657-4907-afb0-2fdeb6ad39f8", "name": "7f12debb-47ea-4b10-814d-ebf7df7088b1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4699462180170992, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3815978523472859, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f722faea-19a7-4445-a5ba-aabe9951ae25", "name": "91821276-4178-4e96-9357-2242c8f18dcf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4f7e210b-8657-4907-afb0-2fdeb6ad39f8"}}}]}, {"uuid": "b3032777-00a4-4e8d-b124-8e1154386c77", "name": "load_p1rlv13725_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e290046b-c936-4f51-b4ef-632bf572ab7f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f722faea-19a7-4445-a5ba-aabe9951ae25"}}}}, {"uuid": "0e7e24f0-18d9-4954-a6ec-adedf0f98db4", "name": "fadc48c3-d531-4be2-b3d2-977404485f0c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4699462180170992, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3815978523472859, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "16112990-2183-48fd-b59c-e1c31239ab37", "name": "01c5727b-1947-47bd-aa23-129b2373e7f0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0e7e24f0-18d9-4954-a6ec-adedf0f98db4"}}}]}, {"uuid": "ecf2d690-b53e-409e-bd12-3fe278a4a408", "name": "load_p1rlv13725_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e290046b-c936-4f51-b4ef-632bf572ab7f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "16112990-2183-48fd-b59c-e1c31239ab37"}}}}, {"uuid": "ea59716e-ff02-4fe0-96c9-98334af45343", "name": "ccb1f4b6-7666-40ab-805b-387e4127deff_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.559543722017981, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7101531402521069, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "024d4b5b-caec-4dd8-9523-0dd3f77ec616", "name": "77ee0385-e9d9-4ce9-9814-3f1f72612aa2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ea59716e-ff02-4fe0-96c9-98334af45343"}}}]}, {"uuid": "a1074246-39b6-4a84-9bb3-bab5de04efcb", "name": "load_p1rlv13726_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "642597e6-fe60-442f-b356-2be6f21677b2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "024d4b5b-caec-4dd8-9523-0dd3f77ec616"}}}}, {"uuid": "8097c180-7252-4a8f-a0c2-31caa4e0bcd5", "name": "d5075581-9fed-4669-a63b-22e5f594bb9f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.559543722017981, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7101531402521069, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1612c2b3-272a-438e-a8a2-9c070b656f67", "name": "f41c0c3f-0dbb-445c-89f4-14d751b99d4c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8097c180-7252-4a8f-a0c2-31caa4e0bcd5"}}}]}, {"uuid": "772e3056-1184-4bbd-8456-11bb88f849a8", "name": "load_p1rlv13726_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "642597e6-fe60-442f-b356-2be6f21677b2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1612c2b3-272a-438e-a8a2-9c070b656f67"}}}}, {"uuid": "570b274f-388c-4c5e-8765-e1f43c2d99c8", "name": "a73059bb-e437-48a1-a2e4-b6ea38a2ec24_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.70898089652498, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7830599711618245, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a3e04680-3dfe-4696-aa2f-3d698a557628", "name": "914c2206-d850-42aa-9034-897718169bba", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "570b274f-388c-4c5e-8765-e1f43c2d99c8"}}}]}, {"uuid": "32c8420d-bc08-4ddf-8ad2-5c1a91750b99", "name": "load_p1rlv13727_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36019623-eb62-412c-a591-41494980c9b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a3e04680-3dfe-4696-aa2f-3d698a557628"}}}}, {"uuid": "045e5b4c-a5d1-493d-b89f-abaec81c479b", "name": "595944c9-4275-4c6a-8559-118d0090546e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.70898089652498, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7830599711618245, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1f4e5df6-c5db-4a5d-8c90-987416e54d98", "name": "923d034c-aa7d-4a9f-b117-fc14c9d85510", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "045e5b4c-a5d1-493d-b89f-abaec81c479b"}}}]}, {"uuid": "23ec0f8d-ad28-4acf-833c-91ed0581460c", "name": "load_p1rlv13727_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36019623-eb62-412c-a591-41494980c9b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1f4e5df6-c5db-4a5d-8c90-987416e54d98"}}}}, {"uuid": "2f09022f-95e8-4f03-94eb-632b3deb5bb2", "name": "5e42c9ef-4052-4d9d-96a7-e6436c2a4815_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 12.611907582113087, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.885290064059574, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c9f56e64-a595-48aa-a382-bcb537d235f4", "name": "e80b2ee4-a8a5-4d22-b5bb-257be53e5acc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2f09022f-95e8-4f03-94eb-632b3deb5bb2"}}}]}, {"uuid": "9a416140-7041-43b6-b2bd-25ee741cb466", "name": "load_p1rlv13728_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9657a993-0005-4ffc-8c9f-18e80a491070"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c9f56e64-a595-48aa-a382-bcb537d235f4"}}}}, {"uuid": "6835f5d8-a666-42d4-9f3f-4c86fe3ed12a", "name": "cac9a18c-75a4-4d56-a1cd-2880d62c8486_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 12.611907582113087, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.885290064059574, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "053915d4-d4ac-42e4-b303-1e25bbde93b1", "name": "2f2112f0-e24c-4a82-9929-c3bc07c98c09", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6835f5d8-a666-42d4-9f3f-4c86fe3ed12a"}}}]}, {"uuid": "92fc514e-a83d-4451-935b-c49f7cee00a2", "name": "load_p1rlv13728_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9657a993-0005-4ffc-8c9f-18e80a491070"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "053915d4-d4ac-42e4-b303-1e25bbde93b1"}}}}, {"uuid": "0b48ddbd-a8b0-489e-9867-ef8439109a26", "name": "9297ef60-e9ea-4582-843d-ca70d318c44d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.028781788264419, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6709073147144231, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "12d5a0f8-56fc-40b7-8f45-1bf67557aee7", "name": "a105314f-aa53-4476-942b-c5766d404511", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0b48ddbd-a8b0-489e-9867-ef8439109a26"}}}]}, {"uuid": "e2fe9658-1741-473a-bd57-9eb0b2f3485f", "name": "load_p1rlv13784_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01a18948-75cf-4caf-951f-17a9c8d1f6bc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "12d5a0f8-56fc-40b7-8f45-1bf67557aee7"}}}}, {"uuid": "7306ded9-8b69-4dbe-86d5-7ea4fb33190c", "name": "086b660b-e051-4ebe-8a74-ed7483f89e33_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.028781788264419, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6709073147144231, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e85fd6fb-5334-49b7-8a84-405c8bb4daa7", "name": "9494e3dd-556a-41ff-a9ef-3612c4ae268e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7306ded9-8b69-4dbe-86d5-7ea4fb33190c"}}}]}, {"uuid": "d4e8b427-9fc7-4230-85f4-304d66ccd6c9", "name": "load_p1rlv13784_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01a18948-75cf-4caf-951f-17a9c8d1f6bc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e85fd6fb-5334-49b7-8a84-405c8bb4daa7"}}}}, {"uuid": "ae3335b0-295f-42bf-9b0d-e8c237fc40ce", "name": "4060d010-a34b-4f61-8baf-4b0fe8cf82ab_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7293ed3d-db31-4b0f-84ed-e1072d29fbec", "name": "fb539322-9819-40d4-b232-831a1dde2861", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ae3335b0-295f-42bf-9b0d-e8c237fc40ce"}}}]}, {"uuid": "e8de7c85-8abc-4098-92f1-6c262259c9af", "name": "load_p1rlv13792_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc5fcb56-435a-4a0d-b442-7489a98ad1cd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7293ed3d-db31-4b0f-84ed-e1072d29fbec"}}}}, {"uuid": "d2033207-79e4-41b4-872b-3ed0e60c5126", "name": "d4f5c4fa-ad8a-4e7b-a6ca-6797dbe1c260_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "be6d7968-c8a6-4621-aded-3efc1b5efcdf", "name": "042507ee-5a14-4ec3-9d92-871b2b26fa62", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d2033207-79e4-41b4-872b-3ed0e60c5126"}}}]}, {"uuid": "474c83a9-55f4-443c-b6fd-1267c438ab86", "name": "load_p1rlv13792_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc5fcb56-435a-4a0d-b442-7489a98ad1cd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "be6d7968-c8a6-4621-aded-3efc1b5efcdf"}}}}, {"uuid": "5b948bc6-9a04-4795-bfa9-01eb6d87861c", "name": "f74d6c3d-0371-4640-ab31-1c93d9435f40_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1648375907215343, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4430202395847888, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3757cab6-2ee7-4a95-9d71-ee3846d99760", "name": "f29f50b2-b0c2-4aac-9fb3-11b6e10eacf8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b948bc6-9a04-4795-bfa9-01eb6d87861c"}}}]}, {"uuid": "729053e2-f61f-4ddf-a62e-79e8d78caee2", "name": "load_p1rlv13794_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9725b6c-5bac-456a-bb6a-ce16a5e6b1a5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3757cab6-2ee7-4a95-9d71-ee3846d99760"}}}}, {"uuid": "22f8b219-1ab3-4775-8009-4d45ab313fe2", "name": "cf79beb3-0468-457c-93c0-5927e700c10b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1648375907215343, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4430202395847888, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e19d4fa9-8881-432a-96f0-f4c01ce935d6", "name": "3a35aef1-8f52-4b9f-8de2-b4a9e23b2983", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "22f8b219-1ab3-4775-8009-4d45ab313fe2"}}}]}, {"uuid": "1a73fa78-912f-42a0-b075-c5e4f8e75dab", "name": "load_p1rlv13794_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9725b6c-5bac-456a-bb6a-ce16a5e6b1a5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e19d4fa9-8881-432a-96f0-f4c01ce935d6"}}}}, {"uuid": "2b094398-1b00-4649-8d7d-ec234c2cddf5", "name": "62c30933-adac-4a05-b9f2-bee562077aa1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9518333270985427, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3340330193202704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3f11dbf6-443f-4bdf-aee0-650b675953bc", "name": "9a000fbc-b2e7-4a6c-9203-504fefd68405", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2b094398-1b00-4649-8d7d-ec234c2cddf5"}}}]}, {"uuid": "88688a62-05b0-48d5-a2fc-b720e3b3611e", "name": "load_p1rlv13797_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65052833-aec9-4363-a0cf-4d70fa9bb0ce"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3f11dbf6-443f-4bdf-aee0-650b675953bc"}}}}, {"uuid": "b9ce6736-7aa9-4e91-a962-bf314292f154", "name": "85fdcf94-c44a-429f-aab8-c3604ee2a35e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9518333270985427, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3340330193202704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1e15fbf3-d3eb-46e6-9043-f08cba648a41", "name": "72e7bea1-9154-4c38-b781-660b6f0b1f12", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b9ce6736-7aa9-4e91-a962-bf314292f154"}}}]}, {"uuid": "b7f8b025-5f44-4628-aebc-fb733bf3a827", "name": "load_p1rlv13797_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65052833-aec9-4363-a0cf-4d70fa9bb0ce"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1e15fbf3-d3eb-46e6-9043-f08cba648a41"}}}}, {"uuid": "d008dff8-0eca-43b2-a489-dddf1259f8b1", "name": "8263be69-f301-49f1-ad74-aff7cea45575_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.661093206685493, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9884186563142763, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2c148610-e18e-42ff-86f5-86f7e7d46e1c", "name": "33001303-0875-48b6-9db5-97731631a2ce", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d008dff8-0eca-43b2-a489-dddf1259f8b1"}}}]}, {"uuid": "1c9bbfba-9960-4261-8309-cf060c9695a0", "name": "load_p1rlv13805_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83d60921-a1f2-4b9c-9709-d2be59b82db5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2c148610-e18e-42ff-86f5-86f7e7d46e1c"}}}}, {"uuid": "d99dc7bf-d409-4931-8fca-5f94a2b89c2d", "name": "f1db1921-7c69-4ceb-a463-94b278426670_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.661093206685493, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9884186563142763, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "46ebd613-17d9-427f-9c79-d5e5beeb5dec", "name": "98235c32-1c83-4c03-8da0-0d2c93bd8a2a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d99dc7bf-d409-4931-8fca-5f94a2b89c2d"}}}]}, {"uuid": "f1119480-14dc-4bfe-bc02-83f47b1c6f79", "name": "load_p1rlv13805_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83d60921-a1f2-4b9c-9709-d2be59b82db5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "46ebd613-17d9-427f-9c79-d5e5beeb5dec"}}}}, {"uuid": "f99e86d1-f09c-4c75-a62c-86a281b8e3de", "name": "b85266ba-b80c-4fd8-a566-d2195631ff4e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4464370236076721, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16599396793014964, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bf53e031-d4a6-48aa-a830-5c127fd126cb", "name": "c7f377ac-0f6f-45f4-94d6-62ce97af7fd5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f99e86d1-f09c-4c75-a62c-86a281b8e3de"}}}]}, {"uuid": "b310fa6b-3561-4f44-8c02-3fe5845177b1", "name": "load_p1rlv13811_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aef2ef8-706c-4316-be01-0707ddf0ac7c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bf53e031-d4a6-48aa-a830-5c127fd126cb"}}}}, {"uuid": "54c9112e-beac-4376-98fb-29a9fcd58369", "name": "497ad5bf-510b-454f-8e94-b0e25fc99de0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4464370236076721, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16599396793014964, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3f6629e0-d2f9-4154-9736-947e7689538b", "name": "72b40a6b-934a-44df-974f-5f432dfb5ea5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "54c9112e-beac-4376-98fb-29a9fcd58369"}}}]}, {"uuid": "4ae17924-c7b0-46b0-96b7-eb50d517392e", "name": "load_p1rlv13811_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aef2ef8-706c-4316-be01-0707ddf0ac7c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3f6629e0-d2f9-4154-9736-947e7689538b"}}}}, {"uuid": "bdab4977-8247-45c9-b12d-2c32d8ab1531", "name": "dd9d5f22-24e3-4e93-822d-9f8855946932_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4868228207229564, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16976956391895093, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ec7818b8-f415-4595-9286-203cafa19f52", "name": "3406079d-61de-4f6a-98e0-94b3c6186342", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bdab4977-8247-45c9-b12d-2c32d8ab1531"}}}]}, {"uuid": "d85187ab-becb-484f-9857-aa2f29732078", "name": "load_p1rlv13812_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ffd737b-a273-4a6c-91c6-351b5719f658"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ec7818b8-f415-4595-9286-203cafa19f52"}}}}, {"uuid": "bedef87c-cbc5-4343-8474-fdc4146c18ef", "name": "ccd49114-65bb-46d0-b5bf-20327daf6b3a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4868228207229564, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16976956391895093, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a33faf8d-ee17-4d08-ae59-f31c6d3430b7", "name": "e985d90e-4301-48f8-ac94-7932b0618b99", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bedef87c-cbc5-4343-8474-fdc4146c18ef"}}}]}, {"uuid": "2f70ad94-00e8-4947-9e08-561f3609687b", "name": "load_p1rlv13812_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ffd737b-a273-4a6c-91c6-351b5719f658"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a33faf8d-ee17-4d08-ae59-f31c6d3430b7"}}}}, {"uuid": "4ec6c000-17d6-4c00-bb2f-69d9421922fb", "name": "ed2a0538-3156-40d4-ba8a-b0061f7ae68a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2596055778412756, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4460523908595607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b3f55c19-e53c-43aa-b18a-7806debc8e10", "name": "fcfe9690-2ba1-4777-8755-0e648a44743e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4ec6c000-17d6-4c00-bb2f-69d9421922fb"}}}]}, {"uuid": "23a8dfde-cdf0-451c-b9bc-aee846edd2e6", "name": "load_p1rlv14434_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06135bd7-6a77-4f04-a439-4ce8c245447d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b3f55c19-e53c-43aa-b18a-7806debc8e10"}}}}, {"uuid": "50ec0c20-f152-4fd9-bdc8-ee03a07ede22", "name": "32214626-4faa-45ff-abe3-5416beeae5df_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2596055778412756, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4460523908595607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "37ced1c4-aaba-4f1f-85f2-327c2445e6f8", "name": "5f0e1323-82cf-4eed-9712-6fd2cc97e929", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "50ec0c20-f152-4fd9-bdc8-ee03a07ede22"}}}]}, {"uuid": "0a8f122e-7a9a-482f-a8c6-baeea7a29ca9", "name": "load_p1rlv14434_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06135bd7-6a77-4f04-a439-4ce8c245447d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "37ced1c4-aaba-4f1f-85f2-327c2445e6f8"}}}}, {"uuid": "2d0e31de-a0df-46f1-af90-1b937b60ca43", "name": "7cbf61d5-0ee4-47ce-9378-2b7d7c9764b9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.904546554088597, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7711735109904765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1aa2825e-0efd-4844-a72b-6df0455193e5", "name": "3c187500-8a3f-4463-8769-bf684e0c7eaf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2d0e31de-a0df-46f1-af90-1b937b60ca43"}}}]}, {"uuid": "081fe3c5-fef8-4a22-bc81-65e9d2728088", "name": "load_p1rlv14435_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d07f5065-df41-484d-8e8a-80b2ff4e0e9b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1aa2825e-0efd-4844-a72b-6df0455193e5"}}}}, {"uuid": "471a413f-2eaa-4197-bece-c67b603b162a", "name": "8ee074cf-d8bd-40db-acdd-38204fd9aa91_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.904546554088597, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7711735109904765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b734a13b-49ba-4216-981a-a1c26b8442c2", "name": "17d0d18e-bb91-411a-b7f1-b8ea738d3cfb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "471a413f-2eaa-4197-bece-c67b603b162a"}}}]}, {"uuid": "99d1a71f-f989-47fc-9f83-39b676d187bd", "name": "load_p1rlv14435_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d07f5065-df41-484d-8e8a-80b2ff4e0e9b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b734a13b-49ba-4216-981a-a1c26b8442c2"}}}}, {"uuid": "5e9875d5-2bd2-4a80-9fb0-5aa1837a67ca", "name": "f7f82c80-17c7-4f51-b255-1e93d8e027cc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.756100999166533, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1794980420068588, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "80d5b990-bd78-4ae5-a3b9-1d77a3da445b", "name": "7445fd14-5983-48a7-87ca-6e5659032878", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5e9875d5-2bd2-4a80-9fb0-5aa1837a67ca"}}}]}, {"uuid": "b9f752a7-b6e4-405d-add0-812f294bcf81", "name": "load_p1rlv14436_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad66e41a-88ab-443e-b10e-9e7b5b899119"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "80d5b990-bd78-4ae5-a3b9-1d77a3da445b"}}}}, {"uuid": "aff84010-8b8c-4a7f-9d4c-2c43694a952c", "name": "dbbbf139-0f95-48f5-acaa-086e1c44c25d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.756100999166533, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1794980420068588, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5cf4d181-0b70-4419-be75-5d3190cb1735", "name": "bef3bd59-9ee9-45c6-abb9-3fb7e9de4705", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aff84010-8b8c-4a7f-9d4c-2c43694a952c"}}}]}, {"uuid": "5564228d-f485-4130-86a3-04573a3e29b9", "name": "load_p1rlv14436_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad66e41a-88ab-443e-b10e-9e7b5b899119"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5cf4d181-0b70-4419-be75-5d3190cb1735"}}}}, {"uuid": "0dbe7793-0d47-4fe5-b038-3b999b242fae", "name": "4750cf80-9c97-4274-a712-b73798096b15_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7653657521185364, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4426471780914222, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3b82e80a-6324-40d2-b374-9db33fa5ef57", "name": "594897a8-f6aa-4272-b22b-26448d576c26", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0dbe7793-0d47-4fe5-b038-3b999b242fae"}}}]}, {"uuid": "82aca4f2-6c5b-4bc0-aae2-b5a49a64d263", "name": "load_p1rlv14828_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9efa4c9-9832-4aa8-bf44-be0fe1e80cd5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3b82e80a-6324-40d2-b374-9db33fa5ef57"}}}}, {"uuid": "5903d2f9-91a7-435c-a8cb-1f11fb6a26a6", "name": "87761cbc-dbf1-499a-a572-16632761c2ef_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7653657521185364, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4426471780914222, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "68492e2a-6570-4bce-a33d-57f001e3234d", "name": "a6054e8b-ee23-467a-bcd2-bc1425d9c6de", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5903d2f9-91a7-435c-a8cb-1f11fb6a26a6"}}}]}, {"uuid": "4c2198f5-7b12-499e-8ed8-99d3054d67db", "name": "load_p1rlv14828_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9efa4c9-9832-4aa8-bf44-be0fe1e80cd5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "68492e2a-6570-4bce-a33d-57f001e3234d"}}}}, {"uuid": "2f9dd3b5-b8b8-4e57-b14a-7648ea564701", "name": "045a91b1-8843-4bc1-8108-7545409dc696_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1976836424562762, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1051220183522544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c44694fe-ec4b-4975-90d4-b20dfc47bfda", "name": "27abf23f-031c-4ff8-a27f-946c42b90b7d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2f9dd3b5-b8b8-4e57-b14a-7648ea564701"}}}]}, {"uuid": "62705e48-23c3-40f1-ba30-985371f037f0", "name": "load_p1rlv14908_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d73b0321-e181-4ecd-b431-9aa6985d56d0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c44694fe-ec4b-4975-90d4-b20dfc47bfda"}}}}, {"uuid": "13973059-1455-492f-aa8d-4f0949f37171", "name": "de2f93d0-3b7f-47ef-847c-60e38ab38cf5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1976836424562762, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1051220183522544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c586f4c7-ef88-4352-8862-0775454adae6", "name": "41def184-fcb6-41ff-a21f-b6c96c5b1e91", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "13973059-1455-492f-aa8d-4f0949f37171"}}}]}, {"uuid": "5fb5c5f4-eb51-4b8f-964d-bda964502433", "name": "load_p1rlv14908_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d73b0321-e181-4ecd-b431-9aa6985d56d0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c586f4c7-ef88-4352-8862-0775454adae6"}}}}, {"uuid": "c451fcb3-16fc-4ab4-b742-9685f3c20147", "name": "046c2e5c-9bcd-49b7-985d-ff87924957d4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9dc3c26b-791e-418e-8438-ab88c139d380", "name": "793240ef-b02c-4623-b140-29599685560b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c451fcb3-16fc-4ab4-b742-9685f3c20147"}}}]}, {"uuid": "d353f84e-cf15-45cb-8dfe-3c455036fa82", "name": "load_p1rlv14952_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3c39b0c-9c92-4934-876f-ee5f542f95cc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9dc3c26b-791e-418e-8438-ab88c139d380"}}}}, {"uuid": "ada1f288-eb32-40fa-a93c-b178dc471a25", "name": "e6624cbc-01a1-4d75-a74d-6f51903b1cb6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7978430e-b47f-471e-abf3-c557209eb1af", "name": "71ca7f34-1f1f-4d74-b942-b183995d7a2b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ada1f288-eb32-40fa-a93c-b178dc471a25"}}}]}, {"uuid": "9c5c9761-f21a-4ed3-bbc7-c95e9ac88e6e", "name": "load_p1rlv14952_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3c39b0c-9c92-4934-876f-ee5f542f95cc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7978430e-b47f-471e-abf3-c557209eb1af"}}}}, {"uuid": "55ab0755-f6d0-4afe-a977-e9fe416d48e2", "name": "9a9b70aa-72c9-48c4-a97a-893f6c40a381_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.374506393438246, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.694445400364831, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0edb6602-5e0c-49db-af53-afaac6863971", "name": "81b0d1c0-35ef-4ae8-a27d-231ab99ead98", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "55ab0755-f6d0-4afe-a977-e9fe416d48e2"}}}]}, {"uuid": "ba37f6a9-d2e1-45fd-93f2-5592c7c07386", "name": "load_p1rlv14954_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9e128f5-eb18-44df-8ec4-35bd049ef630"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0edb6602-5e0c-49db-af53-afaac6863971"}}}}, {"uuid": "1b602400-59f5-47f9-9bde-fdaac8e37572", "name": "94af954a-5059-44d9-af06-f44215920afb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.374506393438246, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.694445400364831, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7b432e8c-65cf-4990-a136-2379e96e5e79", "name": "1ddba20c-906e-43c1-99f8-eb531288b44e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1b602400-59f5-47f9-9bde-fdaac8e37572"}}}]}, {"uuid": "3acda848-9982-497f-bebc-bed963f86579", "name": "load_p1rlv14954_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9e128f5-eb18-44df-8ec4-35bd049ef630"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7b432e8c-65cf-4990-a136-2379e96e5e79"}}}}, {"uuid": "faaf63ea-d3bd-4351-83df-e6a9432ebd55", "name": "6af9cafb-9b46-471d-a620-d791cde8077a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.749950841708346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2019248045205122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fc221dbf-f8e8-4ad9-bbf9-d8ae1e8a99f3", "name": "77966535-8c36-425a-9913-dcd3e54c7a90", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "faaf63ea-d3bd-4351-83df-e6a9432ebd55"}}}]}, {"uuid": "02ceef6f-f4f0-4a1d-bf34-d2b1cae4ccc5", "name": "load_p1rlv14974_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "884ff47e-8e20-4ae8-97bd-287d0ca9dc1b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fc221dbf-f8e8-4ad9-bbf9-d8ae1e8a99f3"}}}}, {"uuid": "a47ccb41-9101-4862-9919-266c22934ac6", "name": "41281d89-de87-494a-b10d-2065930fe40d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.749950841708346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2019248045205122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a7de7a39-b75c-496a-aa48-cac2e1e4e315", "name": "af67500e-fe6b-4ac5-b512-ab34bdc795d8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a47ccb41-9101-4862-9919-266c22934ac6"}}}]}, {"uuid": "935fef31-6064-44c6-b4e7-1d67031960e8", "name": "load_p1rlv14974_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "884ff47e-8e20-4ae8-97bd-287d0ca9dc1b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a7de7a39-b75c-496a-aa48-cac2e1e4e315"}}}}, {"uuid": "1c8a1050-9e99-4748-a965-b48dc79e1a7b", "name": "208ed43a-7564-4026-8572-a2af145b4198_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.446531565278448, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9314679219387375, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3d6ac767-6b08-40a3-afe2-fd754bdb6e44", "name": "6c859f0b-a1fc-46b5-9113-1bd2784ae024", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1c8a1050-9e99-4748-a965-b48dc79e1a7b"}}}]}, {"uuid": "e1739cc0-2f69-4dd4-8772-857e3b95a2da", "name": "load_p1rlv14992_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4f8b1bc-83c3-4819-9d98-9491df98d494"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3d6ac767-6b08-40a3-afe2-fd754bdb6e44"}}}}, {"uuid": "fa59870f-88a2-4890-9295-c01066faa555", "name": "b35a08ad-9702-4e0a-8707-72a6299a3d62_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.446531565278448, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9314679219387375, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a0f7b08-80b8-4e40-9c1f-5305c35720f2", "name": "f299f9be-c5b0-42ab-b5f5-5f804bd03d2f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fa59870f-88a2-4890-9295-c01066faa555"}}}]}, {"uuid": "9419b869-2e79-4f11-9b36-8a2d43f5ca86", "name": "load_p1rlv14992_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4f8b1bc-83c3-4819-9d98-9491df98d494"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0a0f7b08-80b8-4e40-9c1f-5305c35720f2"}}}}, {"uuid": "2d368127-8205-4442-9a21-37ee30d3f334", "name": "cab7b5f5-254d-4612-b29a-ee256010e346_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.667455481738122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8122169683202977, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f1435521-c53a-4628-ba0c-29fab58ef34f", "name": "424231c3-871e-42ab-b340-3810cde2a19c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2d368127-8205-4442-9a21-37ee30d3f334"}}}]}, {"uuid": "e519484b-3290-497d-8b32-be3a202acc1d", "name": "load_p1rlv15007_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc29de5b-3a3f-40c0-bde4-9a57f5f62b5c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f1435521-c53a-4628-ba0c-29fab58ef34f"}}}}, {"uuid": "af7b4c86-76f9-4a08-808b-3faf1fda48be", "name": "3dfb5887-53cb-4e9d-862f-0c648e2d0aae_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.667455481738122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8122169683202977, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "be2aac07-1e00-474e-a6c3-5451a234ac7d", "name": "633c8a6c-8ee7-43de-8e99-a75ffe5c6223", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "af7b4c86-76f9-4a08-808b-3faf1fda48be"}}}]}, {"uuid": "333f0478-984e-4add-baac-b5bded1c612d", "name": "load_p1rlv15007_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc29de5b-3a3f-40c0-bde4-9a57f5f62b5c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "be2aac07-1e00-474e-a6c3-5451a234ac7d"}}}}, {"uuid": "3b4a6592-f755-44ef-8cf2-2744c004d806", "name": "7df558ba-4f9b-4d05-802a-84fe6da2eba6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7847716543397305, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8567239737527961, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c10a1df-1289-4c5d-95cc-6ae363879d1b", "name": "f699cd67-9d6c-42de-af3e-3b5b25db4abf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3b4a6592-f755-44ef-8cf2-2744c004d806"}}}]}, {"uuid": "e796f84b-ec7a-4323-9053-423934ab8911", "name": "load_p1rlv15008_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19231152-1fd1-4e07-a5d9-603c765b2cae"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c10a1df-1289-4c5d-95cc-6ae363879d1b"}}}}, {"uuid": "155d9294-2026-4595-a10f-5d1d3370d942", "name": "d1ff1274-c897-4045-a6ab-1bc942556d49_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7847716543397305, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8567239737527961, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4cf1c416-9a98-4133-abfb-d14595d37519", "name": "58be0c17-d02f-4a51-81ea-eb67be621b58", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "155d9294-2026-4595-a10f-5d1d3370d942"}}}]}, {"uuid": "e4f20f75-2bf9-44b6-9665-9dcfd0831802", "name": "load_p1rlv15008_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19231152-1fd1-4e07-a5d9-603c765b2cae"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4cf1c416-9a98-4133-abfb-d14595d37519"}}}}, {"uuid": "88061b2d-03dd-4bef-b2aa-c5113d39db92", "name": "3d8d4048-7d53-47a2-9ff8-b98a7c5a734d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6848010607962993, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6615616037111118, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "33b2a2ec-137a-40da-bab7-0d9db8e29dba", "name": "2c8cc345-ec14-454c-a3df-7999de4b373e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "88061b2d-03dd-4bef-b2aa-c5113d39db92"}}}]}, {"uuid": "ef3cd349-73a6-4848-b20b-cdd1218fcd31", "name": "load_p1rlv15027_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07e3b847-cc9a-4f84-bc00-cb4396b6dea0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "33b2a2ec-137a-40da-bab7-0d9db8e29dba"}}}}, {"uuid": "0bb0048a-e1a5-4541-9c5b-7b1754279a93", "name": "36d9565b-932f-4eac-8928-c87b2db194cc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6848010607962993, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6615616037111118, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4010dd0f-be87-4210-ab11-20b47a6824f2", "name": "5a251cb6-cfea-45a4-a2ab-a30edaea99f1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0bb0048a-e1a5-4541-9c5b-7b1754279a93"}}}]}, {"uuid": "14061709-05d6-4809-a0fb-8de5dbb878c7", "name": "load_p1rlv15027_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07e3b847-cc9a-4f84-bc00-cb4396b6dea0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4010dd0f-be87-4210-ab11-20b47a6824f2"}}}}, {"uuid": "aa3ecebd-b7f6-453c-b107-f9de938836e8", "name": "18d1cbb6-315b-4ac8-8058-357d964badc0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.297417532176794, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2780703813036578, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "065b9b89-c7a5-42c6-a9ad-b1f750c56c53", "name": "23ed7327-4f19-48a3-b8ec-a1246c3101a3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aa3ecebd-b7f6-453c-b107-f9de938836e8"}}}]}, {"uuid": "abf89700-c23c-4f1f-9986-f9363dd66505", "name": "load_p1rlv15045_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "baccbdab-efc0-487d-b00d-38d3d4be57b4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "065b9b89-c7a5-42c6-a9ad-b1f750c56c53"}}}}, {"uuid": "e82a813c-40b1-4474-94ad-105922c9197a", "name": "be588434-76bf-42da-8db0-63712217a3ad_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.297417532176794, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2780703813036578, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6fdb5567-a8c7-45aa-9049-70c86ad648bf", "name": "892b9695-55fc-43ed-a900-4ad2df7299a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e82a813c-40b1-4474-94ad-105922c9197a"}}}]}, {"uuid": "5e9e9d33-d84f-422b-aec3-bd7049a99b07", "name": "load_p1rlv15045_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "baccbdab-efc0-487d-b00d-38d3d4be57b4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6fdb5567-a8c7-45aa-9049-70c86ad648bf"}}}}, {"uuid": "54f59e7b-dbde-4448-9adf-2c3b2b205aee", "name": "0d9b2913-0b05-4723-a677-45647949f9dd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3054635933061174, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.028189505661142127, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "35859e7f-0203-421f-b7e1-95a5d1f8bdad", "name": "5aabebba-312c-4cd1-9dcb-ab9c9f89edef", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "54f59e7b-dbde-4448-9adf-2c3b2b205aee"}}}]}, {"uuid": "7b61f36b-0fd8-4db1-8d5e-3bd2e69ded78", "name": "load_p1rlv15046_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2182c9fd-fd3d-4cb1-b525-192480823e2f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "35859e7f-0203-421f-b7e1-95a5d1f8bdad"}}}}, {"uuid": "d5da2654-9c5d-4151-b380-9a54ef5dff84", "name": "76b214c4-32dd-43ae-ae73-5a04d373e4c6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3054635933061174, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.028189505661142127, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fbcde39a-5be9-4ee4-a007-905fc48dd499", "name": "6d9364c1-db81-416b-bf4a-944575d28809", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d5da2654-9c5d-4151-b380-9a54ef5dff84"}}}]}, {"uuid": "c8817eda-96ee-4de0-974b-5a4ee8e2d700", "name": "load_p1rlv15046_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2182c9fd-fd3d-4cb1-b525-192480823e2f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fbcde39a-5be9-4ee4-a007-905fc48dd499"}}}}, {"uuid": "0ed66465-c93e-4bbc-b6d8-f8733570df59", "name": "d483b59c-359c-4b8a-b4ee-4bd199f54e33_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.605318582042619, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.38786447308176675, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82256a60-b4fc-44df-9a90-638422679924", "name": "019726b9-c3ea-4490-adab-f9f7dd742641", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0ed66465-c93e-4bbc-b6d8-f8733570df59"}}}]}, {"uuid": "399a3df4-6083-444d-9d10-92ade5bb7bbe", "name": "load_p1rlv15056_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a914ec3a-4883-42a7-b25d-133a1410b8d9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "82256a60-b4fc-44df-9a90-638422679924"}}}}, {"uuid": "f7a4e74b-d00d-493e-8ed3-48318ab6318d", "name": "74a33022-3750-4c48-9101-1b0b94dab6ab_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.605318582042619, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.38786447308176675, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5833379c-cf4a-404e-bc1f-c2005aa40cef", "name": "ddac8155-a00a-4162-849f-c9787c308814", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f7a4e74b-d00d-493e-8ed3-48318ab6318d"}}}]}, {"uuid": "e2c58061-9dbe-45ce-a721-8992f3b96cae", "name": "load_p1rlv15056_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a914ec3a-4883-42a7-b25d-133a1410b8d9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5833379c-cf4a-404e-bc1f-c2005aa40cef"}}}}, {"uuid": "084827a7-20ea-4302-b255-ff892f846062", "name": "45eed0da-500b-4355-8d8b-3fa3d64c28b7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.038374933892965, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6403266957226059, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c1901508-d644-40b5-af80-37c5ad1ef045", "name": "35ff5b24-e1f4-4870-8339-b09c76f3720c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "084827a7-20ea-4302-b255-ff892f846062"}}}]}, {"uuid": "3f51b6de-6dd3-4676-bb1e-e6b39419098e", "name": "load_p1rlv15064_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "366c9c98-59f1-46d5-b39c-4046703e5e4b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c1901508-d644-40b5-af80-37c5ad1ef045"}}}}, {"uuid": "5e1dd03d-0244-4a37-81c9-224edc02ae81", "name": "ee724805-ca62-43cc-b825-61971b140f9f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.038374933892965, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6403266957226059, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e51d4f22-e74d-40ed-b32e-1e608c2e9942", "name": "7e215efb-c2fa-4670-a122-ab9e908d23c0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5e1dd03d-0244-4a37-81c9-224edc02ae81"}}}]}, {"uuid": "85803038-b368-41b8-a135-3e5c87d7c73e", "name": "load_p1rlv15064_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "366c9c98-59f1-46d5-b39c-4046703e5e4b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e51d4f22-e74d-40ed-b32e-1e608c2e9942"}}}}, {"uuid": "7ef14852-87ee-49f6-a01e-3b2f0d54d045", "name": "7764dae3-4df1-4ec9-a275-9586e0c11678_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5369480608064634, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2969034126636569, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "392c267e-bbf0-4ebf-9128-1bb9f19f45c2", "name": "0e554282-ef8b-4bd7-9f95-bd3134747501", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7ef14852-87ee-49f6-a01e-3b2f0d54d045"}}}]}, {"uuid": "4c962874-3ff5-4ffd-9a2e-03dd51d5caa5", "name": "load_p1rlv15082_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a56b9ad8-c53b-4652-bf94-a7a7dfb8b306"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "392c267e-bbf0-4ebf-9128-1bb9f19f45c2"}}}}, {"uuid": "afd3dd67-a714-44d8-b648-025a873bcc66", "name": "9e168c79-e6f8-46e4-9b5f-308d69d2a3de_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5369480608064634, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2969034126636569, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d78aa811-e5de-47d2-8a6e-ca859e6d274d", "name": "8ffaefe2-8f9b-40ee-8efb-997d246a6f78", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "afd3dd67-a714-44d8-b648-025a873bcc66"}}}]}, {"uuid": "0e534536-98df-4d0e-a2b2-c57f662230ad", "name": "load_p1rlv15082_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a56b9ad8-c53b-4652-bf94-a7a7dfb8b306"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d78aa811-e5de-47d2-8a6e-ca859e6d274d"}}}}, {"uuid": "8a16342a-f4dc-49bc-a03d-0b6ef94b5c8a", "name": "2ee01cca-a911-4d27-b1f1-32145c9f8a0b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.694404982351279, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0468171481890831, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dce3bd76-dd92-4a29-bdae-8f511f6a66de", "name": "1ab69093-721c-4b03-a875-566ccccd6991", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a16342a-f4dc-49bc-a03d-0b6ef94b5c8a"}}}]}, {"uuid": "3ea19cfb-febf-4c3e-834f-4bb5374952c5", "name": "load_p1rlv15109_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "161d4e7b-30f2-447c-a369-1bfa3ba2cd70"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dce3bd76-dd92-4a29-bdae-8f511f6a66de"}}}}, {"uuid": "16f16d5b-6d41-4e21-8374-2b49c353e3ae", "name": "9ffa5173-e5de-4d02-98a8-40351f2d63c0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.694404982351279, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0468171481890831, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f06eae7f-b1db-45c7-8ec8-81018096d1ed", "name": "fc22c1f4-36ec-4c93-83d8-52906a7c3b5c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "16f16d5b-6d41-4e21-8374-2b49c353e3ae"}}}]}, {"uuid": "77da50e4-307b-46ce-9a51-879e6dc63b3e", "name": "load_p1rlv15109_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "161d4e7b-30f2-447c-a369-1bfa3ba2cd70"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f06eae7f-b1db-45c7-8ec8-81018096d1ed"}}}}, {"uuid": "31580ad3-7e99-4aa5-8204-f7f827d1ba17", "name": "451c0e75-b2d5-42a5-a87a-b70884307d2f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9518333270985427, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3340330193202704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "643ee3e6-5e93-441a-adb3-a7e109757722", "name": "e1085673-f52e-4199-b3d0-537d5669de47", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "31580ad3-7e99-4aa5-8204-f7f827d1ba17"}}}]}, {"uuid": "4370f7f8-8420-4bbe-a500-4e4c6f80e0ae", "name": "load_p1rlv15125_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb6d8f13-f04e-4b80-a8dc-e16af1dc860e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "643ee3e6-5e93-441a-adb3-a7e109757722"}}}}, {"uuid": "a85898a5-2e15-440e-b099-8b28ced7c56d", "name": "0308184c-c1ca-4b58-a025-7bfc339d1646_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9518333270985427, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3340330193202704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e72c23e9-be35-479c-b4ad-f19d089ff9f0", "name": "923523d9-abbf-4aa6-b18c-e9c265f73f11", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a85898a5-2e15-440e-b099-8b28ced7c56d"}}}]}, {"uuid": "b13aabec-dc96-44ec-aaeb-f00a782ba1b1", "name": "load_p1rlv15125_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb6d8f13-f04e-4b80-a8dc-e16af1dc860e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e72c23e9-be35-479c-b4ad-f19d089ff9f0"}}}}, {"uuid": "367fdd34-4284-448b-9b5b-14e8c663b7f4", "name": "87f0776a-0237-453d-ad1f-4eb39b4fea02_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.386602840079273, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.360256050049383, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "59541744-25fc-4a62-85f1-6fd5a167211e", "name": "df98da5e-a000-4aa1-873a-297a7e9fd7f6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "367fdd34-4284-448b-9b5b-14e8c663b7f4"}}}]}, {"uuid": "5ed7c0aa-1d90-4cb5-b068-f3bde5ccae4f", "name": "load_p1rlv15163_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdee6d84-9253-4fba-b713-3e41d706e999"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "59541744-25fc-4a62-85f1-6fd5a167211e"}}}}, {"uuid": "6a34efdc-e3cc-45b7-a203-7bf5b2c81eb8", "name": "5786607c-5f81-40a4-889f-ee57750faeb2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.386602840079273, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.360256050049383, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4f3a6f0a-3726-4ff0-9e98-0f1b860ef874", "name": "c46c090a-58bb-49eb-b6be-1396413b297f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6a34efdc-e3cc-45b7-a203-7bf5b2c81eb8"}}}]}, {"uuid": "ba90f2b2-b807-4a1a-b4d7-7610eb475222", "name": "load_p1rlv15163_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdee6d84-9253-4fba-b713-3e41d706e999"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4f3a6f0a-3726-4ff0-9e98-0f1b860ef874"}}}}, {"uuid": "0a6bd41f-0854-469a-bfba-2a896c3a06cd", "name": "2ff222e2-6676-45cd-91b2-7c319b22d5eb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0472938281946713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.40441110210881914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "94810cc7-42eb-448b-86bf-3e77db5adbf2", "name": "12e0771d-de5e-44a2-bf41-a3380bdb0e0b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0a6bd41f-0854-469a-bfba-2a896c3a06cd"}}}]}, {"uuid": "f4cdda81-b2ef-465c-a7ad-ab4debb3e111", "name": "load_p1rlv15170_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d2f8fcb-c279-49d5-88be-39e6a1d1990b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "94810cc7-42eb-448b-86bf-3e77db5adbf2"}}}}, {"uuid": "6ea36083-ee4d-4b49-a387-e7ffb21a84d3", "name": "e38edbdf-acca-456f-9f26-475bd1e7d4ca_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0472938281946713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.40441110210881914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7698473e-55ad-4675-ab96-c68f73e202f5", "name": "f10da870-1a98-4f9d-afa0-1508d9e6ff83", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6ea36083-ee4d-4b49-a387-e7ffb21a84d3"}}}]}, {"uuid": "f5153213-5736-4896-bac5-e95ec3efd810", "name": "load_p1rlv15170_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d2f8fcb-c279-49d5-88be-39e6a1d1990b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7698473e-55ad-4675-ab96-c68f73e202f5"}}}}, {"uuid": "f59209e3-2b75-467b-bf26-981f82c0e69f", "name": "70a64c03-6187-4053-b7cb-e3b2c5bf19e7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.664483224984605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9538644530515166, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "856d1ccc-4a6d-4801-8277-40e6862d50d0", "name": "5f63d5f7-f371-4ccf-9779-492f8bb8b7bc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f59209e3-2b75-467b-bf26-981f82c0e69f"}}}]}, {"uuid": "c2829c3c-272c-4006-ac8d-2617e0370e62", "name": "load_p1rlv15171_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc7cd505-823c-49bb-9e49-3681267dbef0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "856d1ccc-4a6d-4801-8277-40e6862d50d0"}}}}, {"uuid": "d051dd30-ae89-4c67-bd43-6fc4bedd9e0a", "name": "9178c9dd-5219-4698-8f52-aff2f22d2a89_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.664483224984605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9538644530515166, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "122d26a5-f9de-45b9-9ceb-b225d56dc0a6", "name": "f07b5511-be53-44ef-a699-ffefe90618e7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d051dd30-ae89-4c67-bd43-6fc4bedd9e0a"}}}]}, {"uuid": "e9c8b1e2-fa10-41aa-b5e8-0d968a4089c8", "name": "load_p1rlv15171_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc7cd505-823c-49bb-9e49-3681267dbef0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "122d26a5-f9de-45b9-9ceb-b225d56dc0a6"}}}}, {"uuid": "cf9ef428-0e5a-41c0-9c22-c7f3d850f628", "name": "eb19f670-a0bc-4be3-b2a4-fddbb14459d8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.13715702476687, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3795210711832634, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6d52cec0-b460-40fd-81ac-984c9828e283", "name": "5c25944f-08e8-4657-bb47-4a19930fa56b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cf9ef428-0e5a-41c0-9c22-c7f3d850f628"}}}]}, {"uuid": "97641359-1a44-4cd8-bf51-68f7244a794f", "name": "load_p1rlv15180_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e218b01d-f713-4baf-9688-7e77ea413c8c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6d52cec0-b460-40fd-81ac-984c9828e283"}}}}, {"uuid": "0b591a3e-599f-4ac2-ba18-13d14f36399b", "name": "097eb900-2025-4532-bd56-c5e7a836dfd5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.13715702476687, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3795210711832634, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eb3821c5-b7f6-4dc7-a87d-0f997549dd8f", "name": "b2d3304c-0cd9-4650-98f7-ad3323236733", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0b591a3e-599f-4ac2-ba18-13d14f36399b"}}}]}, {"uuid": "80234a72-b646-458d-abc5-b1b670dfbea6", "name": "load_p1rlv15180_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e218b01d-f713-4baf-9688-7e77ea413c8c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eb3821c5-b7f6-4dc7-a87d-0f997549dd8f"}}}}, {"uuid": "ed6adb50-d2ca-49e7-a0af-b3b711ba22b9", "name": "48cad7ff-4b21-496f-9b7e-9111795dc989_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3ad66fff-9252-46e1-b701-234b54d06850", "name": "48cad7ff-4b21-496f-9b7e-9111795dc989_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "489a8e34-f115-4e1f-ba31-2e6c13f264dc", "name": "48cad7ff-4b21-496f-9b7e-9111795dc989_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2222dae9-b9d5-49d4-aa6d-52ccb4e86ffc", "name": "5a1590d8-ac99-4377-8c29-883964d907e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ed6adb50-d2ca-49e7-a0af-b3b711ba22b9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3ad66fff-9252-46e1-b701-234b54d06850"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "489a8e34-f115-4e1f-ba31-2e6c13f264dc"}}}]}, {"uuid": "e5e211ef-445f-464a-84c5-1d7868cc3b32", "name": "load_p1rlv15196", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64634ab5-a5b0-45ae-9763-7d0be029350f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2222dae9-b9d5-49d4-aa6d-52ccb4e86ffc"}}}}, {"uuid": "4f307380-46d3-47c5-bba9-20e079c512ef", "name": "e6b472bb-8ae6-4320-a7b4-b9e96dd4c826_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4727091425662127, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8266013407121705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b8d65bc3-6366-42e6-ac9e-caccf2d56ab6", "name": "d51de9e1-d937-49e5-aae4-012dc576d5af", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4f307380-46d3-47c5-bba9-20e079c512ef"}}}]}, {"uuid": "ddbe7663-6055-4269-bf3f-4f47ab59854f", "name": "load_p1rlv15197_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80a74c6f-c9ec-4742-8fce-ad73c0a6c459"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b8d65bc3-6366-42e6-ac9e-caccf2d56ab6"}}}}, {"uuid": "05ade002-e5e3-4957-983a-7f25931b4b86", "name": "c243d62d-2a4c-4ae1-a4e4-14354d15208b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4727091425662127, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8266013407121705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ca6a98e8-6a77-4566-8bdf-e2588884c9ff", "name": "a28bcc36-e94a-4c0d-9c1d-7c39e9077f4c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "05ade002-e5e3-4957-983a-7f25931b4b86"}}}]}, {"uuid": "774fbd6f-5d4f-41c7-9763-5dd3326edeb4", "name": "load_p1rlv15197_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80a74c6f-c9ec-4742-8fce-ad73c0a6c459"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ca6a98e8-6a77-4566-8bdf-e2588884c9ff"}}}}, {"uuid": "1a64cd3e-a5e7-4c88-a5c9-6a434d68f282", "name": "99fafce9-bcbf-4dbf-b1ea-efde3eec11e6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0052757727111112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4127143879372469, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "53d4034f-4912-4542-8654-099b40e784aa", "name": "c1de5b63-1ec2-43b6-a095-e8a2bd069689", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1a64cd3e-a5e7-4c88-a5c9-6a434d68f282"}}}]}, {"uuid": "14b42caf-a810-40b6-8ce9-ecf6b5736e12", "name": "load_p1rlv15394_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd21ae8b-7841-43b4-871f-316c4b8b4cd2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "53d4034f-4912-4542-8654-099b40e784aa"}}}}, {"uuid": "aaf24261-ff1e-401a-8dc7-a40cd8c20954", "name": "fde98af1-a25f-4925-abb1-965c61a64a24_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0052757727111112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4127143879372469, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "93905f3d-11ae-48b8-a283-dbb7b338bb5e", "name": "b1a83f36-c226-4a2c-a50f-aff46bc2b790", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aaf24261-ff1e-401a-8dc7-a40cd8c20954"}}}]}, {"uuid": "128c9748-eb61-41b0-982c-2c4247dfc49e", "name": "load_p1rlv15394_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd21ae8b-7841-43b4-871f-316c4b8b4cd2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "93905f3d-11ae-48b8-a283-dbb7b338bb5e"}}}}, {"uuid": "992cfd71-f12f-4830-9dec-091fa7812f7d", "name": "7f690059-902d-4fb4-a079-c3235de18eb5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2767849318619047, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.48605417385422345, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "442d77e5-1dca-4571-a3e5-ac4e43a550ed", "name": "1f87872c-f748-4725-a7ea-bceb11b82b15", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "992cfd71-f12f-4830-9dec-091fa7812f7d"}}}]}, {"uuid": "934e91ae-163b-4971-abd3-a22c61cc0d93", "name": "load_p1rlv15399_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ec1f313-f341-498c-b1c2-6669b1cbc629"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "442d77e5-1dca-4571-a3e5-ac4e43a550ed"}}}}, {"uuid": "9248525f-1675-4fc4-9811-af7fd9d4f41c", "name": "3e590369-cf2f-4e43-9c1e-24d74b8f9b9f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2767849318619047, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.48605417385422345, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0b2184b1-a104-41e6-9370-e2099151cc50", "name": "9a3c549e-db8d-45ca-b44e-ec1e12111b3c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9248525f-1675-4fc4-9811-af7fd9d4f41c"}}}]}, {"uuid": "191ea403-3045-4b32-a91f-e399b4afbde0", "name": "load_p1rlv15399_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ec1f313-f341-498c-b1c2-6669b1cbc629"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0b2184b1-a104-41e6-9370-e2099151cc50"}}}}, {"uuid": "f63f659e-6f78-4805-890a-ab555465155b", "name": "0f710b31-0344-4368-9937-9c8df3e60cde_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.962031206451152, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.4366749645571537, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5c0485ab-103f-4e09-adac-9ea1fd468772", "name": "2f07204f-afcd-4e4f-a142-362e75288834", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f63f659e-6f78-4805-890a-ab555465155b"}}}]}, {"uuid": "c089d7eb-49d0-4147-a56e-a1d180a82959", "name": "load_p1rlv15418_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9ca373a-b1c3-464d-bbe3-c05b728beb30"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5c0485ab-103f-4e09-adac-9ea1fd468772"}}}}, {"uuid": "7acbdd19-a91c-419d-b26e-0dfa678951c5", "name": "1095f810-19fd-4e77-acf7-75afaf7eda5e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.962031206451152, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.4366749645571537, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "441f6f39-d3fa-4365-a20e-46ad21d3c6e2", "name": "2e040e4d-bf95-4452-b67f-8367ad8815a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7acbdd19-a91c-419d-b26e-0dfa678951c5"}}}]}, {"uuid": "c713637f-bc7f-4b41-9a3a-30c148f5104e", "name": "load_p1rlv15418_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9ca373a-b1c3-464d-bbe3-c05b728beb30"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "441f6f39-d3fa-4365-a20e-46ad21d3c6e2"}}}}, {"uuid": "d3a9d3fd-1a34-44e4-8200-eee0a284acb4", "name": "b74939b1-fd6e-4f11-8c62-f7dc92cabb82_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.365256087534968, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9406994095530364, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2373d602-d50f-45db-9d74-e71e15007f0e", "name": "2292044b-f6fb-4e61-9d67-9be2743fc8fc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d3a9d3fd-1a34-44e4-8200-eee0a284acb4"}}}]}, {"uuid": "20a84130-1e07-46c3-a786-3c298f7ca770", "name": "load_p1rlv15419_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8bc46399-0276-4ae7-aa8b-4cdd3d3555e8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2373d602-d50f-45db-9d74-e71e15007f0e"}}}}, {"uuid": "f27afbe4-10a3-4ac5-ade2-6bbdd2efb2b0", "name": "cfbae373-28f1-4fdc-ba91-f768f9d0da3f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.365256087534968, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9406994095530364, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ae825d0a-d7ce-4115-ae2e-a1da6ac61fc6", "name": "eded9cdc-5c13-460c-9134-1d7e65e17b67", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f27afbe4-10a3-4ac5-ade2-6bbdd2efb2b0"}}}]}, {"uuid": "be3c7974-aaf8-4b57-9b76-b60866b6f18b", "name": "load_p1rlv15419_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8bc46399-0276-4ae7-aa8b-4cdd3d3555e8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ae825d0a-d7ce-4115-ae2e-a1da6ac61fc6"}}}}, {"uuid": "16476ff1-9623-445d-bc5e-aaa6a2b810a5", "name": "7194d1ad-2e55-4e2b-b643-bb700216f4cb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e1d8e8c1-34c8-4b1c-b9e1-b84b5bbb3cfc", "name": "3a932951-92ce-4fbc-85c0-2c5bcdd3ef0e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "16476ff1-9623-445d-bc5e-aaa6a2b810a5"}}}]}, {"uuid": "ac52531c-a55e-4bf0-b5d2-4d084bb9e315", "name": "load_p1rlv15423_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26009a7e-9bfc-4967-af28-4d8937539eb1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e1d8e8c1-34c8-4b1c-b9e1-b84b5bbb3cfc"}}}}, {"uuid": "c486cd31-8e17-47ee-961e-aec42080087a", "name": "ea850e56-120c-4fac-a9cc-4cddaf1d3bb5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "44f1561b-29cb-47ea-a612-238ac8057242", "name": "187a98ff-7ce4-48b4-a14c-4c538f2bd4eb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c486cd31-8e17-47ee-961e-aec42080087a"}}}]}, {"uuid": "e4273425-20a2-41e6-954c-5ab2df4e2a7a", "name": "load_p1rlv15423_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26009a7e-9bfc-4967-af28-4d8937539eb1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "44f1561b-29cb-47ea-a612-238ac8057242"}}}}, {"uuid": "dbcddb3b-e55f-4b76-9fcf-1d9114e1a182", "name": "f9f528d9-9744-4621-bbec-785f15cc7011_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7411160800233395, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1601349573814363, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "233a1839-ef2e-4e0a-8020-9cb19c9c05ea", "name": "59c9eeb9-e4a9-4356-953a-d0ec6c056115", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dbcddb3b-e55f-4b76-9fcf-1d9114e1a182"}}}]}, {"uuid": "5fc4312b-569e-4e54-b8d5-a8c5e7e0f957", "name": "load_p1rlv15466_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "544be417-0db6-45a7-8314-ec40944781fa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "233a1839-ef2e-4e0a-8020-9cb19c9c05ea"}}}}, {"uuid": "9611ddc9-264a-4100-afb5-47f14ffa366d", "name": "8eb7a877-fc86-45d3-ad46-dff8762e76c8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7411160800233395, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1601349573814363, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "49e70e43-82bf-4626-a209-25e0c3b241f4", "name": "c5532ae5-59cd-4da1-8f85-47d57292a6ea", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9611ddc9-264a-4100-afb5-47f14ffa366d"}}}]}, {"uuid": "bd4cd469-9871-4f86-aa59-8c4c8eeb4afe", "name": "load_p1rlv15466_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "544be417-0db6-45a7-8314-ec40944781fa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "49e70e43-82bf-4626-a209-25e0c3b241f4"}}}}, {"uuid": "9ddeff1c-1865-47b5-9a20-6f4480f52a6a", "name": "74631308-8cae-47cc-9953-c2d80336a11f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7411160800233395, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1601349573814363, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c2945fa0-ff8a-4d7f-8392-1840ea3e35d1", "name": "0c493fbc-aa14-4ae8-951e-aa0d4692833d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9ddeff1c-1865-47b5-9a20-6f4480f52a6a"}}}]}, {"uuid": "1ada6dce-48f3-4868-a6f9-c9413cb6bba8", "name": "load_p1rlv15474_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34e0ffc2-da17-441b-bd4d-26d5a1104712"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c2945fa0-ff8a-4d7f-8392-1840ea3e35d1"}}}}, {"uuid": "0f3eb859-0b60-4406-bf90-21daf8463516", "name": "cb2f7f14-4b4f-4142-ab3d-d86c1f877024_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7411160800233395, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1601349573814363, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5a9977ae-9a9b-4938-9b27-cc4a50d6a106", "name": "d7c4b4ea-d122-4f14-86d5-d8b00795d057", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0f3eb859-0b60-4406-bf90-21daf8463516"}}}]}, {"uuid": "4d230c80-1c74-4403-ac4b-a51751d36efe", "name": "load_p1rlv15474_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34e0ffc2-da17-441b-bd4d-26d5a1104712"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5a9977ae-9a9b-4938-9b27-cc4a50d6a106"}}}}, {"uuid": "bde46da1-4eb0-4327-a607-f4125b62957e", "name": "b4ab7e8c-1e80-4c6d-8097-271037e152d5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.84153235443771, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.447226409705929, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c721f5cd-7665-48e9-822b-b643ca760c4c", "name": "b1002f59-669b-4a7a-b223-b0ce571d42ed", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bde46da1-4eb0-4327-a607-f4125b62957e"}}}]}, {"uuid": "a6d4f5dd-727d-412a-acf1-c047ac85db94", "name": "load_p1rlv15478_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "335df4da-50d2-4fbe-a271-ac04257d35c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c721f5cd-7665-48e9-822b-b643ca760c4c"}}}}, {"uuid": "7b1ce745-357c-4b01-aa87-985d6a6d93ef", "name": "130d584d-ee27-4cf0-b7f9-a354626a372c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.84153235443771, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.447226409705929, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cecd57ee-2d04-4090-8ab6-96fb8a32602c", "name": "d1c5099b-ce74-4f1a-beee-013966dd559c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b1ce745-357c-4b01-aa87-985d6a6d93ef"}}}]}, {"uuid": "5610562d-4d19-4e4b-96d9-2e6f54c7a8d1", "name": "load_p1rlv15478_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "335df4da-50d2-4fbe-a271-ac04257d35c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cecd57ee-2d04-4090-8ab6-96fb8a32602c"}}}}, {"uuid": "10d4058c-cc51-4884-8918-3eabe6c30d8f", "name": "5c33781b-3404-4773-8418-6f4559d102a7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6639c955-f5ea-4a95-8885-340171b23e94", "name": "bc182204-578a-4009-9d2a-53d116b4eb8a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "10d4058c-cc51-4884-8918-3eabe6c30d8f"}}}]}, {"uuid": "339cf270-76e3-42a4-8e2a-30f9527fc3cf", "name": "load_p1rlv15483_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c4e3eac-0b1a-4feb-b39f-079c6d2c1d82"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6639c955-f5ea-4a95-8885-340171b23e94"}}}}, {"uuid": "02eec10f-baad-4d72-8fd2-adfd32006494", "name": "232ddfb9-0f86-4bb7-9e22-c382d8cbeca8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "270f4f58-9952-408d-8edf-87be15ede35d", "name": "24482191-182f-4110-8be8-9af3853180fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "02eec10f-baad-4d72-8fd2-adfd32006494"}}}]}, {"uuid": "5c1376af-a293-4081-a620-91d404fa10f0", "name": "load_p1rlv15483_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c4e3eac-0b1a-4feb-b39f-079c6d2c1d82"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "270f4f58-9952-408d-8edf-87be15ede35d"}}}}, {"uuid": "4d9460f9-f8ea-45a4-a8d8-d4823488d408", "name": "f20cdf6d-fab2-4571-a162-b620ee122f03_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "45439d97-58ce-42f2-bec5-c7b74da13429", "name": "25743876-2804-4dfe-96a3-9e9f6cfed976", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4d9460f9-f8ea-45a4-a8d8-d4823488d408"}}}]}, {"uuid": "5fa72b88-1b29-4b26-a54d-c967ea3e6cd2", "name": "load_p1rlv15484_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6749066f-4739-41ec-8369-8da49dd9e1c8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "45439d97-58ce-42f2-bec5-c7b74da13429"}}}}, {"uuid": "94c50990-e8f0-40b8-a2de-e85f1cdc0cb3", "name": "8257838d-9cc7-4b87-99c8-b8116910d4d4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6ae8cefd-e967-4b54-a346-a5c769ef7a4a", "name": "f817426f-5b7e-4fbc-93b5-7a4f97bf6835", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "94c50990-e8f0-40b8-a2de-e85f1cdc0cb3"}}}]}, {"uuid": "3801303e-0611-4e7b-b70a-2ae965aa8ee3", "name": "load_p1rlv15484_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6749066f-4739-41ec-8369-8da49dd9e1c8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6ae8cefd-e967-4b54-a346-a5c769ef7a4a"}}}}, {"uuid": "2a510bae-755d-43de-b23b-ab8993ce13df", "name": "a8d69f35-1632-45b7-8cd5-541ffa86e572_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5041010955030301, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21577690333785765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "14f155fe-c1f1-44d3-99b0-b99ce0157e64", "name": "8b9a313a-c161-41b2-9dc5-5decb4da3eca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2a510bae-755d-43de-b23b-ab8993ce13df"}}}]}, {"uuid": "6fb69007-5eb9-4a48-9d3b-b7e35932f1b2", "name": "load_p1rlv15487_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "921f8f54-ff83-4d2f-8bf4-ee80bab64ce8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "14f155fe-c1f1-44d3-99b0-b99ce0157e64"}}}}, {"uuid": "bb7f3243-53f3-4af8-901c-e5b6688d9085", "name": "f413b114-08d9-4268-9af4-1a112227dab0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5041010955030301, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21577690333785765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "09e7c2bd-e5e6-47a5-89ee-c10bc7fa7efd", "name": "8d2c276d-6085-4e57-9f7e-cad935bc1bae", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bb7f3243-53f3-4af8-901c-e5b6688d9085"}}}]}, {"uuid": "2f9dfbab-cc48-4d6e-a657-2522ba676563", "name": "load_p1rlv15487_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "921f8f54-ff83-4d2f-8bf4-ee80bab64ce8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "09e7c2bd-e5e6-47a5-89ee-c10bc7fa7efd"}}}}, {"uuid": "4c5a3559-3711-4630-a2cb-1f593c502807", "name": "b30379a4-c9c8-4d1e-a238-a2c504c90b8b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7909002853206712, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1704468602852825, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a291a66b-7b02-4c1e-88d4-80d6f3907695", "name": "10fd141f-c5e0-4494-a3d7-1509990cdf8d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4c5a3559-3711-4630-a2cb-1f593c502807"}}}]}, {"uuid": "e4e71f45-134a-4075-b697-9d222843e30d", "name": "load_p1rlv15488_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6579cc93-2b08-4010-816d-3bef509000cd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a291a66b-7b02-4c1e-88d4-80d6f3907695"}}}}, {"uuid": "3d218d4b-6589-4683-9d50-4f072cf955f9", "name": "a46442de-50e9-4cb2-8bd5-76f12638c054_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7909002853206712, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1704468602852825, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "273f8495-5041-4d50-be86-c5df21cf1202", "name": "e814b988-a237-4f36-a2e0-9eca92db73a3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3d218d4b-6589-4683-9d50-4f072cf955f9"}}}]}, {"uuid": "8ad3ab49-7155-403f-8f7a-db1c665052f7", "name": "load_p1rlv15488_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6579cc93-2b08-4010-816d-3bef509000cd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "273f8495-5041-4d50-be86-c5df21cf1202"}}}}, {"uuid": "9ddaceec-25b1-4e2f-97fe-e0f3bda9eab1", "name": "45abe17e-911f-4a38-90ef-29bf9a2995e1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4163439957648214, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5697938312046736, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f807423-4bcf-462f-9765-e7afcb199c02", "name": "9d8d17ff-60b3-450b-9fa9-181929912aa2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9ddaceec-25b1-4e2f-97fe-e0f3bda9eab1"}}}]}, {"uuid": "b693eeb6-80f6-474f-a21a-04fd615fc669", "name": "load_p1rlv15523_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37ccfa64-1373-49b2-85f6-279abea3c945"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f807423-4bcf-462f-9765-e7afcb199c02"}}}}, {"uuid": "b680a583-c323-4b66-8846-9e0cb1692ee2", "name": "241c0c4f-891a-4ae2-8bd9-8f4b17b2df31_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4163439957648214, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5697938312046736, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "88ae3fc4-dee9-4abb-b7cd-9f1c0c9a2e73", "name": "6b3d4b15-8bbc-4566-bfcc-58aef5610e62", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b680a583-c323-4b66-8846-9e0cb1692ee2"}}}]}, {"uuid": "5ab1fe3e-972c-4829-a87c-bab6ec203b43", "name": "load_p1rlv15523_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37ccfa64-1373-49b2-85f6-279abea3c945"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "88ae3fc4-dee9-4abb-b7cd-9f1c0c9a2e73"}}}}, {"uuid": "bcff2667-a612-43db-b611-5390a5c76156", "name": "896c245a-fddc-4280-b962-53dc8c8b7a65_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2037641724563426, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8275766375494601, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "64635c39-be3f-42a4-b66f-6e623db59e30", "name": "1b4a8ece-7618-47d6-a6ca-d72ab84ae452", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bcff2667-a612-43db-b611-5390a5c76156"}}}]}, {"uuid": "7a60fee1-177c-4473-bb96-ec8044cd167e", "name": "load_p1rlv15525_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6eec860d-08cf-4690-93e6-d909429d363d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "64635c39-be3f-42a4-b66f-6e623db59e30"}}}}, {"uuid": "a56079a2-f22d-4a10-9c2b-2a5a03e028d1", "name": "3353557b-0762-4889-a95f-cbbe120e2d22_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2037641724563426, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8275766375494601, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f5c77b29-b8ef-416b-bd23-ded5d646be5d", "name": "c72c9697-395f-4e8e-8c22-f88adb1c4dbc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a56079a2-f22d-4a10-9c2b-2a5a03e028d1"}}}]}, {"uuid": "ea9b4f68-5e35-439b-a1a2-820e07a5e96b", "name": "load_p1rlv15525_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6eec860d-08cf-4690-93e6-d909429d363d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f5c77b29-b8ef-416b-bd23-ded5d646be5d"}}}}, {"uuid": "f4cd6ac1-0942-444e-a0a8-7c10cdce52b3", "name": "280a77ec-ddcc-443d-993b-a39b278f4390_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.679689620441751, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9077324041357607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "80f4e690-25c1-4a86-87f6-54781fcab371", "name": "b0b7c20a-83e7-4f0c-8716-e548fb66a9f5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f4cd6ac1-0942-444e-a0a8-7c10cdce52b3"}}}]}, {"uuid": "91886b57-b270-4644-aaee-be8a5767e737", "name": "load_p1rlv15542_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b09822b3-a220-48ff-ad4f-62fca602f8b6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "80f4e690-25c1-4a86-87f6-54781fcab371"}}}}, {"uuid": "602a35b7-dba3-42fb-8c10-66468760c864", "name": "ffe9df7b-cc38-4e0f-b2c5-46dff8650db3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.679689620441751, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9077324041357607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c0697a93-163a-4601-81ad-de35e394789c", "name": "455cb216-13e7-48e4-aba4-19da4d9e19cf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "602a35b7-dba3-42fb-8c10-66468760c864"}}}]}, {"uuid": "50d02109-4fa7-425c-b1ec-cf5ea46ed546", "name": "load_p1rlv15542_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b09822b3-a220-48ff-ad4f-62fca602f8b6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c0697a93-163a-4601-81ad-de35e394789c"}}}}, {"uuid": "b5b2ec6f-7406-4e8c-8117-e3743b7aab68", "name": "e5ce500f-b8f4-4f7b-ba76-4a77731bf6f3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7539305984890898, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4187015133753737, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bfce76b1-d370-4fd8-a7f4-a3a9b2e2ce59", "name": "8934b0b2-50fc-4d11-bcbf-0a7501b30eea", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5b2ec6f-7406-4e8c-8117-e3743b7aab68"}}}]}, {"uuid": "e9e2fd04-1682-4241-8f34-246164c32690", "name": "load_p1rlv15603_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "688da57a-6f10-4ef8-8763-202a88c3a495"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bfce76b1-d370-4fd8-a7f4-a3a9b2e2ce59"}}}}, {"uuid": "42e70254-ef9d-47f3-9073-ef5f07401849", "name": "893cabcb-4969-4b8d-910c-775e1f80c569_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7539305984890898, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4187015133753737, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9d85ee74-4d56-475d-8d7d-6a212fd7253b", "name": "e3947cd9-083b-421a-8219-af7133a189fd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "42e70254-ef9d-47f3-9073-ef5f07401849"}}}]}, {"uuid": "67f7ca6b-7c11-434c-8855-4784b10b10f6", "name": "load_p1rlv15603_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "688da57a-6f10-4ef8-8763-202a88c3a495"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9d85ee74-4d56-475d-8d7d-6a212fd7253b"}}}}, {"uuid": "6ffcd115-2598-4bac-bcfc-fb62b8aa15e3", "name": "ad64bf0d-2411-4167-9270-bbf569eec871_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.69722938823788, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6546008506549251, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5bd3bed4-f868-4755-a420-30d0862d64e3", "name": "4be4563f-baab-4b66-a639-dae8729f5310", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6ffcd115-2598-4bac-bcfc-fb62b8aa15e3"}}}]}, {"uuid": "ba1acbf2-320f-4439-a3a9-058703243ea8", "name": "load_p1rlv15606_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c32ce070-e690-4fc1-92ac-f857691de578"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5bd3bed4-f868-4755-a420-30d0862d64e3"}}}}, {"uuid": "f0b37315-8176-4bcd-9b23-2b6f1208dd34", "name": "5ea4e10e-9355-47fc-aefc-ca29575c354e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.69722938823788, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6546008506549251, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e5cbc980-da5d-4976-8239-da70f4814fb8", "name": "38104937-5235-4578-9a80-ed28ecf1f1e0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f0b37315-8176-4bcd-9b23-2b6f1208dd34"}}}]}, {"uuid": "d314859a-4fed-404b-9eb0-4c1bf2504af3", "name": "load_p1rlv15606_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c32ce070-e690-4fc1-92ac-f857691de578"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e5cbc980-da5d-4976-8239-da70f4814fb8"}}}}, {"uuid": "000d3dc0-f13e-4cd1-8023-a518239f75cc", "name": "3e28fefb-5c4e-4f45-9665-959cfbf8e030_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6722127407962883, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033140171384262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "487b316a-6eae-46d8-8da4-a49b958aa033", "name": "41e083f6-fd8b-4d8c-a88c-fbf39b16359a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "000d3dc0-f13e-4cd1-8023-a518239f75cc"}}}]}, {"uuid": "99ab83ce-9bfe-4afe-9493-096f255b300d", "name": "load_p1rlv15607_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32291502-d7be-4b45-8af7-cb217448e73f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "487b316a-6eae-46d8-8da4-a49b958aa033"}}}}, {"uuid": "d0ce0434-a2e1-43af-9811-5850e3713675", "name": "0927996e-7a89-435c-8ac2-9da5f99cdc6f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6722127407962883, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033140171384262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6275d4d4-c7e3-479c-ade6-ca9995459a49", "name": "a78fce1b-9591-4a78-a53e-fef3558fa051", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d0ce0434-a2e1-43af-9811-5850e3713675"}}}]}, {"uuid": "ed46658d-25fa-4de9-93a1-c07bf5b43be0", "name": "load_p1rlv15607_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32291502-d7be-4b45-8af7-cb217448e73f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6275d4d4-c7e3-479c-ade6-ca9995459a49"}}}}, {"uuid": "37e6eb60-0fee-4f18-8a8a-691d4dd6f260", "name": "b17a6cc9-d01c-400d-b251-544ea778886f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.054093584716578, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9114545444360403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8d6d7a31-22b3-4faf-8a02-d37e283c22cb", "name": "6e65c48a-a827-4617-88b1-a1772b15461b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "37e6eb60-0fee-4f18-8a8a-691d4dd6f260"}}}]}, {"uuid": "02ec340a-8c87-4c2b-955e-5aae9a00fb2e", "name": "load_p1rlv15614_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ab2d6dc-f5bb-4320-86f3-bf08bb7cf93f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8d6d7a31-22b3-4faf-8a02-d37e283c22cb"}}}}, {"uuid": "3efb4f1c-9dca-4aa3-87db-2a1037365171", "name": "91fa5bca-4df5-4bf9-a30a-46da7bf654db_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.054093584716578, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9114545444360403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "702de970-2fb2-42de-a18b-eaa10e04da4d", "name": "339375d0-a740-4ced-85a1-ea41a96bd866", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3efb4f1c-9dca-4aa3-87db-2a1037365171"}}}]}, {"uuid": "38b862f2-5180-4529-8e6d-63b195d21ccd", "name": "load_p1rlv15614_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ab2d6dc-f5bb-4320-86f3-bf08bb7cf93f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "702de970-2fb2-42de-a18b-eaa10e04da4d"}}}}, {"uuid": "4ed6d4fa-482b-4e4c-a3af-9717ec5571f1", "name": "04a9c41e-514e-46d8-a981-f56c82f86ab6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0288569450045768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2608148575838028, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "760078dd-1eb6-403e-ae47-5fcb613d909f", "name": "90450a01-a2f4-4bdf-bddf-cf971963920d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4ed6d4fa-482b-4e4c-a3af-9717ec5571f1"}}}]}, {"uuid": "363d5f05-c5c1-45fb-8ad1-72cfdc49b352", "name": "load_p1rlv15617_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6106bbe7-7a47-4c50-8b2a-d46d7432bccf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "760078dd-1eb6-403e-ae47-5fcb613d909f"}}}}, {"uuid": "337b3c0a-48de-4e1f-abb0-f7113dfa905c", "name": "f5a3bfb4-2f3c-4665-8f9e-37812e09fe7d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0288569450045768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2608148575838028, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4af8db5e-535a-4b92-b15a-94b672e51c83", "name": "c364696d-a746-482f-a694-2077f40a5a0a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "337b3c0a-48de-4e1f-abb0-f7113dfa905c"}}}]}, {"uuid": "746f94ee-b1ee-4d67-9ea8-0137b0dd340f", "name": "load_p1rlv15617_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6106bbe7-7a47-4c50-8b2a-d46d7432bccf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4af8db5e-535a-4b92-b15a-94b672e51c83"}}}}, {"uuid": "118b10ed-dfde-40ac-bce5-9b60a224ee16", "name": "c423dd2c-9fdf-45de-a9ca-ae80ac1330ca_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3483029031483318, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6505451661884267, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c096a36-d6ee-4d43-8f51-db90300a191b", "name": "17e66d5e-3d71-4238-ad31-0c9e1bd1cea6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "118b10ed-dfde-40ac-bce5-9b60a224ee16"}}}]}, {"uuid": "9b240a29-afa4-4865-8113-dce61285e40a", "name": "load_p1rlv15622_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1151b559-3ae0-4863-9363-9b395bbfc403"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c096a36-d6ee-4d43-8f51-db90300a191b"}}}}, {"uuid": "2b7add0b-c3d1-4d2e-a2a9-20a31032ceaf", "name": "221e5460-385d-4650-90cb-ba64d3817077_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3483029031483318, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6505451661884267, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9f4c6cc9-7df8-41ef-b43b-9b6fa5d9299d", "name": "3a46e619-76b4-44c1-b1e1-10acbd222b4d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2b7add0b-c3d1-4d2e-a2a9-20a31032ceaf"}}}]}, {"uuid": "960c7b61-0dcc-4347-ad5f-706dd7dd4230", "name": "load_p1rlv15622_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1151b559-3ae0-4863-9363-9b395bbfc403"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9f4c6cc9-7df8-41ef-b43b-9b6fa5d9299d"}}}}, {"uuid": "4e34e414-770f-4d2a-8a5b-2541c00f2c38", "name": "4fda3b3e-5dfa-4b73-8a3d-f338684f3ebe_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 12.451565419664076, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.11178199687988, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e87b6646-27e9-40f3-b312-4ae56d20f783", "name": "4fda3b3e-5dfa-4b73-8a3d-f338684f3ebe_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 12.451565419664076, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.11178199687988, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "544c217e-5f15-498a-9750-46173095f189", "name": "4fda3b3e-5dfa-4b73-8a3d-f338684f3ebe_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 12.451565419664076, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.11178199687988, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5619dbe0-729d-496b-a53c-dfa9b5098b3d", "name": "6cd198bd-eba6-4100-9ef6-fd07bee7d54e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4e34e414-770f-4d2a-8a5b-2541c00f2c38"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e87b6646-27e9-40f3-b312-4ae56d20f783"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "544c217e-5f15-498a-9750-46173095f189"}}}]}, {"uuid": "81a3d98f-432e-40e7-9b4c-5838469bd7f6", "name": "load_p1rlv15628", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13eabcb1-332a-4c7a-8042-214ada721424"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5619dbe0-729d-496b-a53c-dfa9b5098b3d"}}}}, {"uuid": "0d0d1323-1ea5-4f85-b268-c6c09adbb522", "name": "8d1d965a-01d1-4b25-85ba-b67975992f72_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0240502132333855, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5295456567023789, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fc8b04d3-ff3a-4865-8fde-5b1bd3b1a8ad", "name": "9b6b6641-24b2-4219-9311-1328277c753a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0d0d1323-1ea5-4f85-b268-c6c09adbb522"}}}]}, {"uuid": "d3b8c2d1-689b-453e-91e9-7b2d36b89d4d", "name": "load_p1rlv15629_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec0bca53-a58b-4004-8dba-8defca9db4c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fc8b04d3-ff3a-4865-8fde-5b1bd3b1a8ad"}}}}, {"uuid": "8fd15230-b131-4c8c-8c58-3f1431ff2688", "name": "c3d46240-f821-4126-bc47-1abfa5d04a49_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0240502132333855, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5295456567023789, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "584328b2-9bf0-49d5-ba52-666575ee7fe6", "name": "e9380927-a696-4fef-ad69-eb89d8704985", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8fd15230-b131-4c8c-8c58-3f1431ff2688"}}}]}, {"uuid": "0ce4f795-f79d-4360-9d3d-c469cefe50ef", "name": "load_p1rlv15629_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec0bca53-a58b-4004-8dba-8defca9db4c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "584328b2-9bf0-49d5-ba52-666575ee7fe6"}}}}, {"uuid": "07faca36-6635-455b-bb11-e5d33dc5fb41", "name": "7a86b912-7590-4f5c-8842-22c89ee1209f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.459276697523187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8425022918187992, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f26f51b1-e972-4612-b052-a598f9da1ed2", "name": "ce8fc209-c9b3-4f81-8c4c-b966dc154461", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "07faca36-6635-455b-bb11-e5d33dc5fb41"}}}]}, {"uuid": "3c23a9e5-e695-4862-a1ed-1b7013922081", "name": "load_p1rlv15634_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5af6dae-d20f-4a31-9544-b9455cd639bd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f26f51b1-e972-4612-b052-a598f9da1ed2"}}}}, {"uuid": "062c5c69-88c0-4ff2-ad09-c6b4f4e6e5c7", "name": "e977cde3-24e0-48e7-952e-4cd42a95a60b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.459276697523187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8425022918187992, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "29e202bb-523d-4a00-92c4-a61cf33b8014", "name": "a8451a90-b696-43d8-9d36-15a3a6a6e378", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "062c5c69-88c0-4ff2-ad09-c6b4f4e6e5c7"}}}]}, {"uuid": "2bec8ef3-d1d1-4375-b3ad-4fcd521998da", "name": "load_p1rlv15634_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5af6dae-d20f-4a31-9544-b9455cd639bd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "29e202bb-523d-4a00-92c4-a61cf33b8014"}}}}, {"uuid": "f4c2e805-198e-4d18-93b9-2bef44ea8c3a", "name": "df77f211-3a0a-498a-89e3-b082fc8ee120_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6524083002915736, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21201745820683848, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "157134c6-e79c-411e-91d9-9ea70e645daa", "name": "57a7b7d3-f679-41f1-9db7-41157808fb4f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f4c2e805-198e-4d18-93b9-2bef44ea8c3a"}}}]}, {"uuid": "48fe9c33-79f4-47bd-9ba3-6a4d2b94dcef", "name": "load_p1rlv15638_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2715a637-d6f0-4e7b-b43e-20836bf4e614"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "157134c6-e79c-411e-91d9-9ea70e645daa"}}}}, {"uuid": "d17d3786-2de1-4665-8df1-993edcc55061", "name": "2ac54f16-2236-410d-99e9-770bb50b4cd1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6524083002915736, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21201745820683848, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "973e1374-c51c-4bbb-b95f-6b9283457b45", "name": "a7af89c0-c088-456c-baf2-7af4041c5da8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d17d3786-2de1-4665-8df1-993edcc55061"}}}]}, {"uuid": "4b180f70-5021-40fe-a7f3-6558f7c9cbd0", "name": "load_p1rlv15638_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2715a637-d6f0-4e7b-b43e-20836bf4e614"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "973e1374-c51c-4bbb-b95f-6b9283457b45"}}}}, {"uuid": "34ae07d1-4965-456f-83b7-f0911007dd8b", "name": "ee1d6b15-d1a0-4357-b0bd-3694826cf032_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1219512592986662, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8685822493081499, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "609d6800-53ba-4091-b201-c639a89f9b22", "name": "14b4f633-e879-4cc6-a1e6-73404bf779da", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "34ae07d1-4965-456f-83b7-f0911007dd8b"}}}]}, {"uuid": "8a26e622-7b55-4e5d-a0c0-c74de1ab2a4d", "name": "load_p1rlv15645_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "449098c3-4f65-4350-863f-4b7bc1f14493"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "609d6800-53ba-4091-b201-c639a89f9b22"}}}}, {"uuid": "6705cba9-52b3-44f6-be0d-5b207c79af4e", "name": "b14e774b-701d-4159-be78-c4cb209404a7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1219512592986662, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8685822493081499, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "292da20d-3df1-41dd-bedc-52931193eedc", "name": "e58612bc-30a2-4e29-b570-95ec6244c410", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6705cba9-52b3-44f6-be0d-5b207c79af4e"}}}]}, {"uuid": "b156a757-1c66-49db-9928-f98fc3643bce", "name": "load_p1rlv15645_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "449098c3-4f65-4350-863f-4b7bc1f14493"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "292da20d-3df1-41dd-bedc-52931193eedc"}}}}, {"uuid": "d3bc3cbe-2ba2-483c-9915-bcb5ce6828ef", "name": "9a5d157c-5747-4591-9475-03cad3a8c47e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.567401274738218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6497123013243786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "343e3115-3ac2-45ff-bdd7-ba9f1eeef288", "name": "137085b1-cbcb-4fee-a841-5b1852556baa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d3bc3cbe-2ba2-483c-9915-bcb5ce6828ef"}}}]}, {"uuid": "c7d94431-5e19-498e-820d-04507086783f", "name": "load_p1rlv16114_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5984e209-9f0e-4844-91e6-902c8329f13c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "343e3115-3ac2-45ff-bdd7-ba9f1eeef288"}}}}, {"uuid": "563d990f-0a48-4bd7-b6be-72ff20388a91", "name": "711144a8-1d7f-4d35-a0a6-e068c2cad6a0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.567401274738218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6497123013243786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "905c6c36-2f29-4f53-9434-9f23eac4da33", "name": "7231060f-4920-43b1-8d1f-19720e20748a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "563d990f-0a48-4bd7-b6be-72ff20388a91"}}}]}, {"uuid": "2d1287d2-7d33-4437-b0d3-ec9948e8b482", "name": "load_p1rlv16114_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5984e209-9f0e-4844-91e6-902c8329f13c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "905c6c36-2f29-4f53-9434-9f23eac4da33"}}}}, {"uuid": "4aadcbeb-c078-40bf-85e3-dc67375c909d", "name": "13cd89b5-b77c-4a31-9214-e520fd74f0ab_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7463758536661063, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1812611818115355, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "13578549-07e9-4bbe-ae2d-0e6934e18e02", "name": "44ce35c9-dc72-4262-bf60-5f311fe0d931", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4aadcbeb-c078-40bf-85e3-dc67375c909d"}}}]}, {"uuid": "271b69d3-beeb-4543-b1cf-1f1820fc4db1", "name": "load_p1rlv16115_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52d1b79d-5c6b-4b44-9998-600c6debd999"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "13578549-07e9-4bbe-ae2d-0e6934e18e02"}}}}, {"uuid": "7d7debbd-e8f9-4216-b4e4-0ae296e425e7", "name": "443a895b-503d-424b-a6d4-48b372820048_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7463758536661063, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1812611818115355, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "20226c39-1722-4a0b-8de8-c3711613ea03", "name": "f44b6716-a448-474e-b9ec-2dd11690db6e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7d7debbd-e8f9-4216-b4e4-0ae296e425e7"}}}]}, {"uuid": "96585543-3d95-45a8-bdc5-a5c1a3ec6ad6", "name": "load_p1rlv16115_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52d1b79d-5c6b-4b44-9998-600c6debd999"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "20226c39-1722-4a0b-8de8-c3711613ea03"}}}}, {"uuid": "7eaaac68-1b01-4f3f-8872-e0a5be83a3b3", "name": "d8d7bb65-b83f-4950-84a4-763f72a4230a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.915650640127065, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8660189470929796, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aefbedba-7672-4b17-9874-24e2cd6fb05a", "name": "55329a86-bb37-49ad-8576-42ccfd21db71", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7eaaac68-1b01-4f3f-8872-e0a5be83a3b3"}}}]}, {"uuid": "88bb12b4-c9e0-438a-9efc-f9ffaeb42d1d", "name": "load_p1rlv16116_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "972f8088-b67b-47d0-a86f-49179dfb1c92"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aefbedba-7672-4b17-9874-24e2cd6fb05a"}}}}, {"uuid": "04857d11-51c4-4ba0-ace8-5adbbacb71ea", "name": "b2e208d9-3790-47b8-b509-ceac371b0cbd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.915650640127065, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8660189470929796, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3098cd40-5dd6-4996-b1bc-fc3eb5f29afe", "name": "7060432c-11ff-45fc-bb69-17cfbbdfb27c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "04857d11-51c4-4ba0-ace8-5adbbacb71ea"}}}]}, {"uuid": "20214244-ec78-4484-b061-527c9dcfdbd9", "name": "load_p1rlv16116_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "972f8088-b67b-47d0-a86f-49179dfb1c92"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3098cd40-5dd6-4996-b1bc-fc3eb5f29afe"}}}}, {"uuid": "e40a3821-f79c-41ff-a11f-257beeec8693", "name": "a4c79aa9-b586-4019-a8cc-1f031e7905d7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8805170689043904, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.699573894302905, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f706d3b6-bcec-4143-947c-09637f36eb4b", "name": "4a9a3c69-4fac-494e-911d-a58c92abf5fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e40a3821-f79c-41ff-a11f-257beeec8693"}}}]}, {"uuid": "728535a5-4d13-458c-aa9a-988562645181", "name": "load_p1rlv16117_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "204899ec-81e4-4a72-bf70-69b3428a49a1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f706d3b6-bcec-4143-947c-09637f36eb4b"}}}}, {"uuid": "abced025-b8ad-43f5-b022-9c333946660d", "name": "fd6642d2-1b4c-4abb-a17c-1b3bc7447566_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8805170689043904, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.699573894302905, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "70e0dfdd-638f-4f98-ab98-9c223d03f62a", "name": "24ccfd03-28f7-438c-b20e-4534cf87b92e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "abced025-b8ad-43f5-b022-9c333946660d"}}}]}, {"uuid": "fe1c3a28-1973-4061-9d97-344b8b71c76b", "name": "load_p1rlv16117_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "204899ec-81e4-4a72-bf70-69b3428a49a1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "70e0dfdd-638f-4f98-ab98-9c223d03f62a"}}}}, {"uuid": "bac6a7f5-ae27-4fe8-a7cf-97cddabffe8c", "name": "e7fc5122-4ade-4b30-ade6-8435292aa7a3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.667455481738122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8122169683202977, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a44049d7-2b72-4a70-ae59-d4cf28f4dd96", "name": "dfd9db79-c670-4723-b1e2-f1d594819506", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bac6a7f5-ae27-4fe8-a7cf-97cddabffe8c"}}}]}, {"uuid": "a54790f2-6d25-4017-8b73-843660042c32", "name": "load_p1rlv16118_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bca0b3a0-d4cb-4a4a-9b14-aa23d9e5e5fe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a44049d7-2b72-4a70-ae59-d4cf28f4dd96"}}}}, {"uuid": "80b5eeea-9887-41a7-85cb-7fe8263902b9", "name": "1287e37f-dfea-4530-88d3-63e5043f53ba_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.667455481738122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8122169683202977, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "982851d7-722b-4f52-80d3-f957ddec7727", "name": "c6aae283-785e-4c94-99c2-c8e66c57a1c1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "80b5eeea-9887-41a7-85cb-7fe8263902b9"}}}]}, {"uuid": "ffeafe96-58a7-470c-8b86-2f5b72c44780", "name": "load_p1rlv16118_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bca0b3a0-d4cb-4a4a-9b14-aa23d9e5e5fe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "982851d7-722b-4f52-80d3-f957ddec7727"}}}}, {"uuid": "25bbbf41-6602-406b-a32c-c824e7d3bce3", "name": "0b667be0-259d-40f1-9575-2c4e63ff572c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7938373145978153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7193647721316423, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "32413a08-1791-444a-ba67-b830c75c7308", "name": "9a1dab1c-b535-4779-8363-a9f1fe9c4feb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "25bbbf41-6602-406b-a32c-c824e7d3bce3"}}}]}, {"uuid": "9dfd712f-d2cf-46ce-9818-46b2e312025e", "name": "load_p1rlv16119_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0d6e608-d5bf-40d6-9efd-f3b0922e7d77"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "32413a08-1791-444a-ba67-b830c75c7308"}}}}, {"uuid": "786605ce-febf-4166-a149-578bf4bb7da0", "name": "cd48b049-2a20-4ed6-b62c-246263e50b6e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7938373145978153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7193647721316423, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "97395db4-d9c1-4d66-aebe-354134b5507e", "name": "9b4fcdb4-3f1c-4478-8682-b5bb89d111fa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "786605ce-febf-4166-a149-578bf4bb7da0"}}}]}, {"uuid": "6c33851b-87c1-46b9-b27f-c13e571c86ce", "name": "load_p1rlv16119_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0d6e608-d5bf-40d6-9efd-f3b0922e7d77"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "97395db4-d9c1-4d66-aebe-354134b5507e"}}}}, {"uuid": "9379c229-f655-4b12-b5b2-ba95f386a272", "name": "bbd65c20-107d-4409-bdde-9ece0c47256b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3480679486659737, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1241770602848328, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "98069f9e-e37e-45ff-99c5-a57a5a77b0b6", "name": "39a00932-92f4-4396-9859-712f0cd45ddc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9379c229-f655-4b12-b5b2-ba95f386a272"}}}]}, {"uuid": "36732ab5-69dc-40c4-9af4-545e9f2c1d0e", "name": "load_p1rlv16124_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6da4b2d0-66c7-43fb-9aab-3bbac03aa989"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "98069f9e-e37e-45ff-99c5-a57a5a77b0b6"}}}}, {"uuid": "7fcc4de7-0719-40e5-9825-8270e73b0247", "name": "a89a7b08-6b09-47c6-a293-ac726779012b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3480679486659737, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1241770602848328, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a6ed8840-408f-46f0-8c09-e37395a9689c", "name": "33f4efba-208a-4673-b449-f8178987c22c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7fcc4de7-0719-40e5-9825-8270e73b0247"}}}]}, {"uuid": "4fc30b64-b173-47ad-955a-f430d7614906", "name": "load_p1rlv16124_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6da4b2d0-66c7-43fb-9aab-3bbac03aa989"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a6ed8840-408f-46f0-8c09-e37395a9689c"}}}}, {"uuid": "84b6495b-045c-4c87-964c-fb0e558e77de", "name": "4c9cc6ed-5aa4-4a20-888b-79f41b0769f6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6733980323267108, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22626974414284334, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4c058a44-e6ea-4de2-bfb9-d76d5ea629b5", "name": "774e1dff-e6e3-4619-ab4b-3303bc8b65c0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "84b6495b-045c-4c87-964c-fb0e558e77de"}}}]}, {"uuid": "d7ba0cd2-bb48-4804-a327-3721f52bfcea", "name": "load_p1rlv16126_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd41f55a-4b5d-4c19-9787-801072b3b946"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4c058a44-e6ea-4de2-bfb9-d76d5ea629b5"}}}}, {"uuid": "d2d481de-1a78-47c2-86e7-445c35b9b344", "name": "a5af0b62-a953-4f46-8b72-045b3490302b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6733980323267108, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22626974414284334, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "516af154-ecbc-4845-8119-06afe55f66f3", "name": "5ffd92d1-5896-49c7-9684-bf107e2205c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d2d481de-1a78-47c2-86e7-445c35b9b344"}}}]}, {"uuid": "8d7846f5-8730-4e0d-88f5-3e63a4dcc72d", "name": "load_p1rlv16126_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd41f55a-4b5d-4c19-9787-801072b3b946"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "516af154-ecbc-4845-8119-06afe55f66f3"}}}}, {"uuid": "5f332d82-e662-4f4d-ab2a-35c89f90831e", "name": "8905e9c5-ac07-4274-9110-4be751a1f451_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5788343693478561, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0852895205351165, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "04912ec8-5a17-4a85-84f7-0c39abc03477", "name": "746ffaf8-e596-4d3e-82fc-8d4900947fd5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5f332d82-e662-4f4d-ab2a-35c89f90831e"}}}]}, {"uuid": "0a976511-8ae9-4638-8c2c-63edd65633a5", "name": "load_p1rlv16133_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "102b9460-ea9a-4099-b16f-40b8fdf99ef7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "04912ec8-5a17-4a85-84f7-0c39abc03477"}}}}, {"uuid": "43a599a2-b62b-4612-8d2f-5884d76620fd", "name": "0d6082fc-9bea-4439-bc0d-ac1ef6436de8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5788343693478561, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0852895205351165, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9139257c-f68d-4bf2-9810-823f373b594a", "name": "342dc2c1-513f-46d8-b794-8d02a17882cd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "43a599a2-b62b-4612-8d2f-5884d76620fd"}}}]}, {"uuid": "74dd4588-7d28-4eb5-9a8d-313f8d179c7e", "name": "load_p1rlv16133_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "102b9460-ea9a-4099-b16f-40b8fdf99ef7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9139257c-f68d-4bf2-9810-823f373b594a"}}}}, {"uuid": "c0619dfd-a505-47a8-9336-79b3ec4dfb0c", "name": "0ca9810b-c5a2-430d-b6fa-554f188fa7fb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6153595559076463, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2889565281407196, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50198a08-3a43-40dc-8571-73b5bb9cd346", "name": "bfabcc6a-d17b-45ff-a2bd-afb9646f33d0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c0619dfd-a505-47a8-9336-79b3ec4dfb0c"}}}]}, {"uuid": "a2a22920-3529-4a47-9552-fee1019b5ed2", "name": "load_p1rlv16135_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "676de1a3-2dfd-4faa-a057-7739e825d136"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50198a08-3a43-40dc-8571-73b5bb9cd346"}}}}, {"uuid": "5043792a-ef7c-4496-a15d-0af4f7af8cce", "name": "9ed3f16b-eb01-4ebd-8e6a-5e66e0002290_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6153595559076463, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2889565281407196, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dcca11b3-d501-43f0-a281-3bc327b529ce", "name": "4a16d233-6640-4ea1-b6d8-ecb6386d9d6c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5043792a-ef7c-4496-a15d-0af4f7af8cce"}}}]}, {"uuid": "e470734e-dcd9-48c2-815a-0c9c72d1085d", "name": "load_p1rlv16135_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "676de1a3-2dfd-4faa-a057-7739e825d136"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dcca11b3-d501-43f0-a281-3bc327b529ce"}}}}, {"uuid": "cbc9698a-1fef-4fad-8688-d01851548ad5", "name": "7b8bc565-3431-4565-aa4f-646ed7b35c4c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0226237890173833, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.014132802344601372, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aef4db55-d145-4590-8c3a-d09b87ccc493", "name": "3cff0272-99e6-4877-af42-f17a0280d099", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cbc9698a-1fef-4fad-8688-d01851548ad5"}}}]}, {"uuid": "5829fc66-d124-4fd0-973b-6a56109a6c70", "name": "load_p1rlv16139_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c840cf3f-be15-448b-8c03-8942c586b135"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aef4db55-d145-4590-8c3a-d09b87ccc493"}}}}, {"uuid": "610f4b2f-b458-4e1a-a61a-d6632506d009", "name": "b4ba9738-c756-4d73-b5b0-0e95b8cd887d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0226237890173833, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.014132802344601372, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8d4da3d0-1148-4838-9d94-9ade8464da1e", "name": "0260069a-20b1-4411-94cc-9ffb795ebca1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "610f4b2f-b458-4e1a-a61a-d6632506d009"}}}]}, {"uuid": "91c435bb-76f2-471a-809d-13817bea407c", "name": "load_p1rlv16139_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c840cf3f-be15-448b-8c03-8942c586b135"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8d4da3d0-1148-4838-9d94-9ade8464da1e"}}}}, {"uuid": "6042efec-a7ab-418b-92e5-3ab83efbb079", "name": "56214b0e-f9e7-491d-a861-a80f43f5f299_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2601927423507288, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13915962527089715, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f6b6d87d-8daf-4cbb-9619-84739c833ecb", "name": "7a214c76-fcac-455f-b323-84b6a728afad", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6042efec-a7ab-418b-92e5-3ab83efbb079"}}}]}, {"uuid": "47b4cccd-4f53-45f0-9b6e-01951fc190d6", "name": "load_p1rlv16146_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6d21c357-1033-45e1-84a0-b82ceafe6ab8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f6b6d87d-8daf-4cbb-9619-84739c833ecb"}}}}, {"uuid": "fd23a6b8-cf91-41dc-b37f-77c1188910ba", "name": "f5874288-2c7b-457e-a546-a9300f69e414_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2601927423507288, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13915962527089715, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c729d70-656f-48bf-874f-573f7d3fad6c", "name": "d42b61b5-1b5d-4c92-8376-63d5c0d743ef", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fd23a6b8-cf91-41dc-b37f-77c1188910ba"}}}]}, {"uuid": "3b572804-1bf4-452f-8c8a-7e83f2a7df9d", "name": "load_p1rlv16146_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6d21c357-1033-45e1-84a0-b82ceafe6ab8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c729d70-656f-48bf-874f-573f7d3fad6c"}}}}, {"uuid": "944e9d08-58c5-471c-b02f-d03631e3b3fd", "name": "4cf50889-ff51-4daa-9594-f9ca031ddf2f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.954715654212962, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.874926311982217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ba4c0a9a-ea5a-47e6-9087-6ccffa088ae3", "name": "06820ee3-82e9-4d51-8bd8-82afe2e820d6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "944e9d08-58c5-471c-b02f-d03631e3b3fd"}}}]}, {"uuid": "e1d9d634-aada-4a41-9782-7b61414d440c", "name": "load_p1rlv16149_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b15792ca-a6bd-47e5-8c67-5c3076174848"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ba4c0a9a-ea5a-47e6-9087-6ccffa088ae3"}}}}, {"uuid": "d82e6c12-c88d-44bf-acac-1c129736f972", "name": "60850e0b-cb39-4f3d-8296-63d7efa32f9f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.954715654212962, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.874926311982217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d0d23c7c-b137-4edb-aa89-8cd506803c05", "name": "1f02f919-b8d7-4dcc-be93-0416be171418", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d82e6c12-c88d-44bf-acac-1c129736f972"}}}]}, {"uuid": "eee641f4-7495-49d4-b0c4-ccad20246869", "name": "load_p1rlv16149_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b15792ca-a6bd-47e5-8c67-5c3076174848"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d0d23c7c-b137-4edb-aa89-8cd506803c05"}}}}, {"uuid": "3fb5e67e-7604-49e0-84b3-242f0a723658", "name": "4f023723-4c1c-4054-982b-8b339729e62e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.199861964544811, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5137601155429989, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "babc2fd3-3af8-477f-83da-3053e5d55d9a", "name": "3a352fc0-24f9-40ff-a303-68dd6b65b760", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3fb5e67e-7604-49e0-84b3-242f0a723658"}}}]}, {"uuid": "62d2f921-6b29-450f-8efd-cc005b8fc836", "name": "load_p1rlv16156_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "74edd9e9-24a5-4b36-8ca8-24ef2fa3e972"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "babc2fd3-3af8-477f-83da-3053e5d55d9a"}}}}, {"uuid": "c638bf32-7feb-4a80-98d7-3f15f7f07683", "name": "c15e25d9-ee81-47b4-93ca-1da39af6a5ec_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.199861964544811, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5137601155429989, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "02dc8948-4499-440f-9062-51b4df1185ed", "name": "af9e2be7-aec7-47c4-9506-4e350d02b583", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c638bf32-7feb-4a80-98d7-3f15f7f07683"}}}]}, {"uuid": "ea4d056f-ebac-4652-a3bb-2f0393cf3e9b", "name": "load_p1rlv16156_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "74edd9e9-24a5-4b36-8ca8-24ef2fa3e972"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "02dc8948-4499-440f-9062-51b4df1185ed"}}}}, {"uuid": "95af027f-f060-48cf-ba7f-7a6bfe81e4d9", "name": "7444f369-9eab-404e-875f-0a874429e148_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8668291909105112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7572719732007044, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2977e7e4-a182-4eda-a621-665cdfea8b72", "name": "7723bebb-c070-4919-b2a4-43332f162739", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "95af027f-f060-48cf-ba7f-7a6bfe81e4d9"}}}]}, {"uuid": "f8017a87-cdf4-45bd-82eb-e1c5d21ff905", "name": "load_p1rlv16157_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6efff4f7-c67b-4cfb-a72d-30b6616825b1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2977e7e4-a182-4eda-a621-665cdfea8b72"}}}}, {"uuid": "0d1ea309-327f-4df9-a825-c720410aea31", "name": "2cd1e795-b6d5-4a6c-aed6-ef98f90064e8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8668291909105112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7572719732007044, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2f7cb9e1-5e4f-43bc-adab-f41910e887df", "name": "0e55a0a1-2deb-495a-9a56-f39a4c2ff82b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0d1ea309-327f-4df9-a825-c720410aea31"}}}]}, {"uuid": "289f48fe-200b-4ef8-bb85-415fb62457eb", "name": "load_p1rlv16157_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6efff4f7-c67b-4cfb-a72d-30b6616825b1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2f7cb9e1-5e4f-43bc-adab-f41910e887df"}}}}, {"uuid": "aadd63b4-0be3-4930-aa43-d0e89a049dde", "name": "340caec7-a6a9-4f57-a9f1-7c0cdd25330e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.927062407458527, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.5614641711041375, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "94718418-e166-4c74-a9f9-afa3c38c5c5e", "name": "10bccbfd-02a7-465a-ae9d-34e6334107d8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aadd63b4-0be3-4930-aa43-d0e89a049dde"}}}]}, {"uuid": "ad302c42-a4e0-4487-baea-30eb493be87c", "name": "load_p1rlv16158_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b85e180a-8eb4-4acc-a816-d99758cc16ea"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "94718418-e166-4c74-a9f9-afa3c38c5c5e"}}}}, {"uuid": "35d8cb9b-ea2b-4ad7-84b6-3ea93abe91cd", "name": "14d8755e-45f8-4f0a-ace9-26a251575b0d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.927062407458527, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.5614641711041375, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e7a4f331-391c-41c2-8708-af3c62c444b1", "name": "ad66d882-04f1-42ea-9b5d-85bf29f490a6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "35d8cb9b-ea2b-4ad7-84b6-3ea93abe91cd"}}}]}, {"uuid": "3d2b97fa-a69b-400b-8c6a-7edcc9ec5e98", "name": "load_p1rlv16158_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b85e180a-8eb4-4acc-a816-d99758cc16ea"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e7a4f331-391c-41c2-8708-af3c62c444b1"}}}}, {"uuid": "8fa57b6a-1070-49a0-ab8c-6fc7653fa1b5", "name": "d8de8e69-c8e2-40bf-ab7d-b1efcb08417f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6923563615826267, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8186846587164974, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f8c69361-b012-4381-9baf-f47e2ace3e35", "name": "7352512f-5a4e-42bf-a268-c90fbaa10bfb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8fa57b6a-1070-49a0-ab8c-6fc7653fa1b5"}}}]}, {"uuid": "ae35f4ab-be01-4151-b28c-bc457b2eaf1e", "name": "load_p1rlv16168_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fb5abb7-dd79-49aa-9185-88a90bb45bc7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f8c69361-b012-4381-9baf-f47e2ace3e35"}}}}, {"uuid": "5518dcf0-ca6d-4c31-8e14-b1fbfcbfc9a4", "name": "8f65fe76-7ec3-4c39-8ade-f8cda2b5adb4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6923563615826267, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8186846587164974, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ee0339eb-6bb9-4623-a309-40f8be220020", "name": "7b56c783-647d-4445-a892-aeeeb23f2214", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5518dcf0-ca6d-4c31-8e14-b1fbfcbfc9a4"}}}]}, {"uuid": "e1291582-16b4-44ff-8b20-af36b4546a35", "name": "load_p1rlv16168_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fb5abb7-dd79-49aa-9185-88a90bb45bc7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ee0339eb-6bb9-4623-a309-40f8be220020"}}}}, {"uuid": "759b6c81-1eff-41f0-91b3-2fa957406b90", "name": "6ceb5dc2-80f4-4575-a4de-ab9a62fd34ed_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.160237576416993, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 5.832362811342285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9e794faa-cc78-43af-92ad-d55e903534c0", "name": "79d156a2-e7af-4303-a866-c151ec2d5e3b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "759b6c81-1eff-41f0-91b3-2fa957406b90"}}}]}, {"uuid": "d37c76fa-d11a-45d6-b583-c9f1d1afe258", "name": "load_p1rlv16177_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbbe8401-53a1-4ce7-9ce1-02f547055d95"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9e794faa-cc78-43af-92ad-d55e903534c0"}}}}, {"uuid": "1ef1acd9-ea6f-4427-8451-dd0f3a5e227b", "name": "ece91088-fedf-4f6c-8fd4-020c63ffe0ae_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.160237576416993, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 5.832362811342285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "11f69efc-00f8-446d-a326-f00471de567f", "name": "ecf2035a-b5a3-40e3-8b14-7cc42e5d2d52", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1ef1acd9-ea6f-4427-8451-dd0f3a5e227b"}}}]}, {"uuid": "11b248f1-2e87-4e52-99d5-ace7c2a21dd7", "name": "load_p1rlv16177_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbbe8401-53a1-4ce7-9ce1-02f547055d95"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "11f69efc-00f8-446d-a326-f00471de567f"}}}}, {"uuid": "7db3fc2b-717d-425d-8ce2-4c368ad8a20a", "name": "31da6973-780b-499b-be21-8c61b7e98b6c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.060834559711965, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4528637167980347, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1ff20224-d53d-4d70-9fc9-a1f7ebf9208d", "name": "0ec4d3cb-1481-450d-b00b-af279a4ef278", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7db3fc2b-717d-425d-8ce2-4c368ad8a20a"}}}]}, {"uuid": "28082638-16ec-4f1c-8f35-73032dfe4ae6", "name": "load_p1rlv16178_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "807b0bef-0d34-44a9-a2a9-0c0a11f4ea8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1ff20224-d53d-4d70-9fc9-a1f7ebf9208d"}}}}, {"uuid": "811f9d5d-2c38-4000-ad90-2407c8ba381b", "name": "2ef15f6f-7918-40d9-b6ca-cc29041b0dbd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.060834559711965, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4528637167980347, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2a3acf25-d5eb-4013-b4a4-c3ae643867c7", "name": "ea4bf838-2578-43ad-adbb-7653cfafd7e0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "811f9d5d-2c38-4000-ad90-2407c8ba381b"}}}]}, {"uuid": "ecac8be1-ae8c-4ff3-a56b-ef59dff62e08", "name": "load_p1rlv16178_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "807b0bef-0d34-44a9-a2a9-0c0a11f4ea8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2a3acf25-d5eb-4013-b4a4-c3ae643867c7"}}}}, {"uuid": "cd990560-ccf7-4e47-b0a8-e54eaf37e8dd", "name": "9b055f05-34e8-4444-b73c-ac788fd443a8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8288850538480296, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31695217299610473, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b66da1a3-044a-46d1-bc15-fd8daeca6076", "name": "9d20ad51-c6df-4719-bbb3-fc460d08236b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cd990560-ccf7-4e47-b0a8-e54eaf37e8dd"}}}]}, {"uuid": "bb67aa8e-9868-4bb1-8164-10d1048423fa", "name": "load_p1rlv16197_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "92a37082-36d4-4eca-95e4-88dbcacd6db5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b66da1a3-044a-46d1-bc15-fd8daeca6076"}}}}, {"uuid": "9f6bbe6b-f152-41c4-9e9b-b4c8e195801f", "name": "24cc580e-f578-4485-b2b0-0fd8d9984bc2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8288850538480296, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31695217299610473, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2fac40fd-4c72-4eab-a08a-7602d5b740a2", "name": "77a10d6c-ca60-44f0-b5b2-ce72b05c0f2d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9f6bbe6b-f152-41c4-9e9b-b4c8e195801f"}}}]}, {"uuid": "61115f7b-14ea-43b1-98ab-6a4501c7e755", "name": "load_p1rlv16197_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "92a37082-36d4-4eca-95e4-88dbcacd6db5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2fac40fd-4c72-4eab-a08a-7602d5b740a2"}}}}, {"uuid": "51f2c6a7-abf8-40e1-b63a-5de2319c2e2e", "name": "8b4c8e30-f340-4d25-b10e-33fb7f7905c5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5775901800387742, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6237657200291109, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "597b73a2-1034-487f-99c0-2d74dc99d141", "name": "887f0fd4-281b-4a24-8373-82d40fd5bab5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "51f2c6a7-abf8-40e1-b63a-5de2319c2e2e"}}}]}, {"uuid": "fb695a11-0908-4b19-a9be-e8d1859b4c5c", "name": "load_p1rlv16200_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1aacea55-115d-46c3-9590-725cf5040f38"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "597b73a2-1034-487f-99c0-2d74dc99d141"}}}}, {"uuid": "e534beb3-a4d4-48f8-a6e7-7359ec2f1afe", "name": "a6e1477d-0917-4b47-9805-9ce404d0acf9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5775901800387742, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6237657200291109, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f8e68d22-1c77-4be7-ab6d-8b8d1a688b41", "name": "4b0eb596-282f-40d0-85d6-92ba67973883", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e534beb3-a4d4-48f8-a6e7-7359ec2f1afe"}}}]}, {"uuid": "188a1dbc-8092-4633-9710-6db102bbac68", "name": "load_p1rlv16200_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1aacea55-115d-46c3-9590-725cf5040f38"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f8e68d22-1c77-4be7-ab6d-8b8d1a688b41"}}}}, {"uuid": "d64fad99-5581-447e-a562-7368e6df2f92", "name": "925da18f-b233-4144-a409-1b24377fec95_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4950137537296666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31506625700854357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c1a632ee-3fca-43e2-a0b4-e237df300bec", "name": "e5fd1e11-75bd-45cf-8120-169d18ecd45b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d64fad99-5581-447e-a562-7368e6df2f92"}}}]}, {"uuid": "8113cfc0-7014-447a-aa9a-a78e4b9a2255", "name": "load_p1rlv16201_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68aa5cc5-f6bf-4417-8653-747c56b37b5e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c1a632ee-3fca-43e2-a0b4-e237df300bec"}}}}, {"uuid": "a0016079-70b3-4a6d-a640-8c3b1e6f6366", "name": "051018c9-0438-41c2-aad2-042ec84613e5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4950137537296666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31506625700854357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "690ba879-c2fe-4b7d-bf13-de4c8ff82366", "name": "eb8acc83-e967-44f1-97f1-480a94e04f1a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a0016079-70b3-4a6d-a640-8c3b1e6f6366"}}}]}, {"uuid": "1a299d11-654b-42f2-9549-0e1ebc5bfee8", "name": "load_p1rlv16201_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68aa5cc5-f6bf-4417-8653-747c56b37b5e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "690ba879-c2fe-4b7d-bf13-de4c8ff82366"}}}}, {"uuid": "82f80507-7e59-4d25-92e4-063d5352e131", "name": "2b930e05-b5ca-4776-b53c-2e93994c5ae3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.668048225868244, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.178282395400973, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "44a99c88-77f8-4547-a76c-e4cd0ceb5057", "name": "6a5b1ff0-2a62-4dae-b3c2-3f72552aaf24", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "82f80507-7e59-4d25-92e4-063d5352e131"}}}]}, {"uuid": "4e5070b5-da69-4033-a231-1ac0d07dd50f", "name": "load_p1rlv16206_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ca42395-8d67-4e83-80ec-159cacb490f8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "44a99c88-77f8-4547-a76c-e4cd0ceb5057"}}}}, {"uuid": "10efa989-c321-4627-b3ea-58a01ecb6c67", "name": "3087cff4-d666-4dc9-983f-07818d2217b4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.668048225868244, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.178282395400973, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6171b61a-c649-477b-b369-585b3d4f9d67", "name": "fcfee667-3a76-4915-a802-ec7625d41b65", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "10efa989-c321-4627-b3ea-58a01ecb6c67"}}}]}, {"uuid": "e6be7fda-f439-4963-ac3f-0d593ded7427", "name": "load_p1rlv16206_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ca42395-8d67-4e83-80ec-159cacb490f8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6171b61a-c649-477b-b369-585b3d4f9d67"}}}}, {"uuid": "6e3a2dd8-9d14-4656-97e1-29404e1858ed", "name": "db2f9d9c-7cc0-48af-b2fa-b337078e7f43_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8202631342288826, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.26720803692022926, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4ca4a8b8-2848-4562-84e4-b3091cabb297", "name": "a05549c7-64ca-4f21-8d1c-9ff1b5cf4180", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6e3a2dd8-9d14-4656-97e1-29404e1858ed"}}}]}, {"uuid": "38baae80-9e2b-4574-b0b8-80c9191778ea", "name": "load_p1rlv16209_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf413742-18c8-483d-b8f1-f125f95323da"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4ca4a8b8-2848-4562-84e4-b3091cabb297"}}}}, {"uuid": "0a051704-0824-4b50-9da2-9a88776bbf00", "name": "00f42130-c93c-426a-8da9-b9e3b3889a1a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8202631342288826, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.26720803692022926, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5072fd2e-6a5d-4f41-94d4-f4b07524235e", "name": "d5b24dcc-7afd-4cb1-a5ef-103b1cf30946", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0a051704-0824-4b50-9da2-9a88776bbf00"}}}]}, {"uuid": "4506020b-9977-4001-b008-07eb54d22c69", "name": "load_p1rlv16209_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf413742-18c8-483d-b8f1-f125f95323da"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5072fd2e-6a5d-4f41-94d4-f4b07524235e"}}}}, {"uuid": "f9622ad8-9c05-4623-94d2-fc3db1729d57", "name": "7ac7b347-6227-4658-8a0e-8d53c99901eb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.621947646480353, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0332384495271123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fa3d3118-0271-46bd-a8fc-ea328754fe18", "name": "cd84c6d0-7df2-4a20-845b-24648ee492c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f9622ad8-9c05-4623-94d2-fc3db1729d57"}}}]}, {"uuid": "da1537bc-3902-43ab-92af-239cf99fac5e", "name": "load_p1rlv16210_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fd05f3c-df77-45bc-8686-458b681a3d08"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fa3d3118-0271-46bd-a8fc-ea328754fe18"}}}}, {"uuid": "73b43497-48f7-4318-bc2b-74717054e651", "name": "2ef7c5ad-edd9-4aea-b435-2de079dea7a2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.621947646480353, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0332384495271123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f7675120-31a6-41cd-a416-bfe9e9b58a99", "name": "7c507e19-95e4-471d-8f33-0ca7d1770368", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "73b43497-48f7-4318-bc2b-74717054e651"}}}]}, {"uuid": "a85789d2-5bdf-40c4-8db0-32a010ac2bb9", "name": "load_p1rlv16210_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fd05f3c-df77-45bc-8686-458b681a3d08"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f7675120-31a6-41cd-a416-bfe9e9b58a99"}}}}, {"uuid": "bd71cb50-0006-42e9-ad81-75ecd8b79a48", "name": "f3080d62-ac16-4d83-8083-e140467ac72e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.08053934867757, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.19082517830123075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b64a5f67-da86-43f2-98ed-6d4f37fc6df6", "name": "9d0be648-054f-4b89-81b6-d49caf009d06", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bd71cb50-0006-42e9-ad81-75ecd8b79a48"}}}]}, {"uuid": "687d59e4-ec09-42fa-8290-945ee573225e", "name": "load_p1rlv16221_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9761003-33fa-482a-967b-b508ab67c19f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b64a5f67-da86-43f2-98ed-6d4f37fc6df6"}}}}, {"uuid": "c92936ad-112a-42cf-a795-6beca08af2e6", "name": "90c9377d-b6c7-4142-bdcc-518269e98dc2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.08053934867757, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.19082517830123075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "248dedcd-95bc-4a77-8661-b69cae451e77", "name": "27753590-42a1-496c-a0eb-79e1a17dd545", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c92936ad-112a-42cf-a795-6beca08af2e6"}}}]}, {"uuid": "25e15c21-5534-423f-b539-7fcdee678078", "name": "load_p1rlv16221_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9761003-33fa-482a-967b-b508ab67c19f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "248dedcd-95bc-4a77-8661-b69cae451e77"}}}}, {"uuid": "2e3a56f0-26d6-49c4-8278-48212669b3a8", "name": "a2b6d15a-95b2-48e7-9736-fea5cb3cf4d2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.0707881481560175, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.1283140369898392, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7d012a1d-6742-41dd-88a6-1cf39c22a3ff", "name": "86520804-049f-4fb5-8729-020319b66c13", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2e3a56f0-26d6-49c4-8278-48212669b3a8"}}}]}, {"uuid": "63aab616-7791-487d-a08b-51972220df8a", "name": "load_p1rlv16222_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4809afc1-2d3d-491d-80e5-9cd4e8da08f2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7d012a1d-6742-41dd-88a6-1cf39c22a3ff"}}}}, {"uuid": "f8befad7-db52-4f5b-bf30-4ec36de002d5", "name": "52968539-b947-42a1-b6e9-cad8ddf1b9e4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.0707881481560175, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.1283140369898392, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bf537ed1-e312-40d7-9588-585e4082e6de", "name": "eeab61f2-224c-4641-98d5-f33d205fe2bf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8befad7-db52-4f5b-bf30-4ec36de002d5"}}}]}, {"uuid": "9dc56401-aa82-4081-871e-dba02af9eb1d", "name": "load_p1rlv16222_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4809afc1-2d3d-491d-80e5-9cd4e8da08f2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bf537ed1-e312-40d7-9588-585e4082e6de"}}}}, {"uuid": "6d324efc-b032-4759-9496-6fcc6bf9f013", "name": "6730beef-de2e-4ef5-8580-c2053e941b70_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7997673490012955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.772957044307952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e7aef740-a876-4527-8c3a-81de3fb33468", "name": "e3c53125-15b6-4022-929c-1aade13ba79e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6d324efc-b032-4759-9496-6fcc6bf9f013"}}}]}, {"uuid": "1dd65483-4544-46ca-87b9-86004f8af419", "name": "load_p1rlv16228_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8767650-39c5-4d4a-80ce-af408c246599"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e7aef740-a876-4527-8c3a-81de3fb33468"}}}}, {"uuid": "08768275-2e22-4df1-8fcf-f8786fd610ab", "name": "75ed1a21-6584-4154-8564-29660d44dd60_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7997673490012955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.772957044307952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "86278f7c-6d66-40a6-9db0-49a2cb509a8a", "name": "017f4552-9fda-4e60-a865-b73ac6f60513", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "08768275-2e22-4df1-8fcf-f8786fd610ab"}}}]}, {"uuid": "23331b8c-8dbd-41bb-96e7-4a9ee02aa8ce", "name": "load_p1rlv16228_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8767650-39c5-4d4a-80ce-af408c246599"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "86278f7c-6d66-40a6-9db0-49a2cb509a8a"}}}}, {"uuid": "2384208f-c3da-4a5f-8774-5ed0b42d1775", "name": "9fb213e2-f60e-45b8-9dec-810063737f0f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.941898785419248, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8498359578625553, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d033bc93-d36e-4320-b499-6180fc5e3379", "name": "6ed32a0e-dbac-4c67-90da-a12fae14e1c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2384208f-c3da-4a5f-8774-5ed0b42d1775"}}}]}, {"uuid": "90c28d38-88fc-4f21-a316-fcf16d1a1721", "name": "load_p1rlv16235_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56b91b3f-dfdd-41bf-9d2e-a8183077c752"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d033bc93-d36e-4320-b499-6180fc5e3379"}}}}, {"uuid": "8ef99890-745e-4393-8325-fb5aa64640bc", "name": "cfc09689-4a41-4315-af0c-0f9e1c456e86_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.941898785419248, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8498359578625553, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "925e289d-82ac-4ac3-8e06-044ce8c912dc", "name": "c19e020c-bc6d-4120-b46a-4ab23c053afc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ef99890-745e-4393-8325-fb5aa64640bc"}}}]}, {"uuid": "f7a053ff-c115-476d-8880-bde065bababd", "name": "load_p1rlv16235_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56b91b3f-dfdd-41bf-9d2e-a8183077c752"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "925e289d-82ac-4ac3-8e06-044ce8c912dc"}}}}, {"uuid": "25e3363b-55dd-43a6-aa7c-52a7119bfeea", "name": "17149634-af64-479f-b5a7-cb5c71a5e4ed_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.992945339168608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.937847717707562, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "208c43d1-94a0-4344-90df-52dc7bd511d7", "name": "d6af770d-529f-4890-9352-0930b950bbb3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "25e3363b-55dd-43a6-aa7c-52a7119bfeea"}}}]}, {"uuid": "02061d0f-f540-4f78-aa26-193fbcf05a3c", "name": "load_p1rlv16239_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9642fa30-e5f7-42f1-8fda-ab75a265d25a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "208c43d1-94a0-4344-90df-52dc7bd511d7"}}}}, {"uuid": "87ba6520-cd25-4ef3-ac5b-39ccf50910aa", "name": "4e13ba8f-b575-487a-8493-6579b0d9c471_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.992945339168608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.937847717707562, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "00d96727-8577-4bde-9d0d-28049794d64a", "name": "47aeb06f-b5f7-464f-b4ff-c4d59927eb8f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "87ba6520-cd25-4ef3-ac5b-39ccf50910aa"}}}]}, {"uuid": "f591e871-f291-4273-b6bb-54f9144cd7f4", "name": "load_p1rlv16239_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9642fa30-e5f7-42f1-8fda-ab75a265d25a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "00d96727-8577-4bde-9d0d-28049794d64a"}}}}, {"uuid": "46676f65-412e-48ff-9fb8-53394bd9f99a", "name": "91b27021-aa12-45e7-aa70-f6bc9731a5b4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9337862827800336, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34425772205755256, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "415a56cf-38ae-4744-89b4-1e397956b57e", "name": "cf8aa6d7-3d6f-4c32-97a6-8b10840f41ba", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "46676f65-412e-48ff-9fb8-53394bd9f99a"}}}]}, {"uuid": "807b2c7b-8421-4be2-9991-525a59224a3a", "name": "load_p1rlv16242_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e82036d9-e6c8-42c3-b45b-30bef6902bbc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "415a56cf-38ae-4744-89b4-1e397956b57e"}}}}, {"uuid": "b8173146-9863-4a87-9624-704836c1d974", "name": "2907befd-8fc1-4310-b863-979de3223721_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9337862827800336, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34425772205755256, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cdd8a788-aa78-4ca7-9f7d-a5b151748276", "name": "fc5124bd-3d4c-4027-a48c-6b95c5adf4ee", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b8173146-9863-4a87-9624-704836c1d974"}}}]}, {"uuid": "c856e52e-6577-42dc-b16d-98eb2b4ba2d7", "name": "load_p1rlv16242_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e82036d9-e6c8-42c3-b45b-30bef6902bbc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cdd8a788-aa78-4ca7-9f7d-a5b151748276"}}}}, {"uuid": "bb93cf86-abd1-416e-9d9a-a6c9bd1ce715", "name": "ad19cd3b-2575-4a5b-b842-a965054e127a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7430249960912554, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9646854683366036, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7c4fa019-913f-42d9-8487-43baf7140118", "name": "85a9a0cd-f507-4cdf-9c94-9642caedde3c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bb93cf86-abd1-416e-9d9a-a6c9bd1ce715"}}}]}, {"uuid": "34c8cbbb-410b-4176-b515-fc86aa512951", "name": "load_p1rlv16243_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20818cc7-617e-4ab7-8f7c-31eea6496a02"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7c4fa019-913f-42d9-8487-43baf7140118"}}}}, {"uuid": "3d681fe6-c130-41b9-b824-051414bea0ef", "name": "b35ab247-2792-4051-a8cd-d1379991b7b5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7430249960912554, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9646854683366036, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c0caf009-8d97-4ccf-a18e-1c4744b66c66", "name": "7fa22bc4-e544-4985-8c30-952326b87d83", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3d681fe6-c130-41b9-b824-051414bea0ef"}}}]}, {"uuid": "067e83ef-33c4-4d7e-b6d2-b897ea32998f", "name": "load_p1rlv16243_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20818cc7-617e-4ab7-8f7c-31eea6496a02"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c0caf009-8d97-4ccf-a18e-1c4744b66c66"}}}}, {"uuid": "bbb7d194-ee30-4c7e-82bf-d6a343c5c099", "name": "c973ef57-4bea-4bf2-a02f-0b9f74f561b2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2766983969851713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5028612878254624, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0be0b900-102a-4d59-842e-2b164d4f82a4", "name": "02e72792-8785-464d-b508-fbbd4ee69536", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bbb7d194-ee30-4c7e-82bf-d6a343c5c099"}}}]}, {"uuid": "13aefa76-b966-4fcc-8857-ad70e07e674b", "name": "load_p1rlv16244_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0164339-acc1-4b95-aa31-3af42cf943f7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0be0b900-102a-4d59-842e-2b164d4f82a4"}}}}, {"uuid": "a78da743-46a7-4c08-a8e1-ceaf896565d8", "name": "ae676b84-86dd-4afa-a0a7-51a4b2fba285_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2766983969851713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5028612878254624, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a629ed77-26cc-4809-8503-c28eae2996f2", "name": "78479dde-0af5-487b-83df-a28f1a9a92fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a78da743-46a7-4c08-a8e1-ceaf896565d8"}}}]}, {"uuid": "fc7bdb18-05b5-4508-89cf-6b2d0be753ae", "name": "load_p1rlv16244_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0164339-acc1-4b95-aa31-3af42cf943f7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a629ed77-26cc-4809-8503-c28eae2996f2"}}}}, {"uuid": "49f92419-0d54-443b-8d43-33d0b1876020", "name": "26f20116-38be-47a3-a72d-30669c1a648e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.13715702476687, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3795210711832634, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6f4efc49-d644-487e-9eff-4333bb378c29", "name": "99f989f4-5b24-45b4-9f1b-0e1a29073b7f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "49f92419-0d54-443b-8d43-33d0b1876020"}}}]}, {"uuid": "79fe76ff-6ba6-465f-95d8-8a6c22d2ab39", "name": "load_p1rlv16245_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3783c838-b72e-42cd-8b0b-3005bca3cf5e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6f4efc49-d644-487e-9eff-4333bb378c29"}}}}, {"uuid": "009fce19-1ad7-46eb-a6a7-2de897f44fe7", "name": "7a433bcd-05e4-4262-b28a-b0dccca99d3e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.13715702476687, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3795210711832634, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b117b8fd-198c-4662-b556-190230cca40b", "name": "fbdb871d-ac90-4986-afb4-98f9f3c46423", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "009fce19-1ad7-46eb-a6a7-2de897f44fe7"}}}]}, {"uuid": "3a382cd8-e1bc-4c1b-9592-198db8d95239", "name": "load_p1rlv16245_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3783c838-b72e-42cd-8b0b-3005bca3cf5e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b117b8fd-198c-4662-b556-190230cca40b"}}}}, {"uuid": "c2a99cd4-f825-458d-884c-65bedb2d91ce", "name": "bb10f447-0dd9-47bb-9b43-bb2438d3ad0c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.133603663599094, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7fbeaf93-c0a2-41e2-93c1-81d2463975fc", "name": "4d94c9b3-5a90-493c-a165-f922cec9ba41", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c2a99cd4-f825-458d-884c-65bedb2d91ce"}}}]}, {"uuid": "cc498e82-9ab9-40a7-b1e3-362b034829b2", "name": "load_p1rlv16246_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd2dc2db-787a-4732-bae4-01186082a92d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7fbeaf93-c0a2-41e2-93c1-81d2463975fc"}}}}, {"uuid": "8fd4c161-fb13-4a88-ad9f-6d89a71bc353", "name": "7c4bb292-324f-44f6-ab57-7d5ef8525060_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.133603663599094, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6b2cf3bb-66d6-44aa-9f18-3339fa5074de", "name": "8e4d0312-8875-4ed0-bf5e-94b2e7461be0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8fd4c161-fb13-4a88-ad9f-6d89a71bc353"}}}]}, {"uuid": "3d44bacf-37ae-4eeb-9ec0-31965edfded3", "name": "load_p1rlv16246_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd2dc2db-787a-4732-bae4-01186082a92d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6b2cf3bb-66d6-44aa-9f18-3339fa5074de"}}}}, {"uuid": "4d5e82c2-d868-4b53-a073-007053cd037b", "name": "20d0f761-6902-4647-9a0e-5e6c1c69413f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0472938281946713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.40441110210881914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "03eef06c-dfb2-4e26-80eb-b44907416c52", "name": "7b959a9f-b5f7-4d58-aebb-ee74e4f8b29b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4d5e82c2-d868-4b53-a073-007053cd037b"}}}]}, {"uuid": "f2fe1b05-e077-42ca-8efb-c10275765edd", "name": "load_p1rlv16247_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8d5e9b7-dc95-41f9-8547-99d5e2eba874"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "03eef06c-dfb2-4e26-80eb-b44907416c52"}}}}, {"uuid": "b1b47682-7ade-48a9-9a13-7e549a05e897", "name": "11ad2d15-c8ad-4963-8a08-54201a231804_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0472938281946713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.40441110210881914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6e7104d0-2c2d-41a3-9fb8-9d72be0b0dcc", "name": "c0a8c15a-8ba9-44ac-98c5-b3d045ad36dc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b1b47682-7ade-48a9-9a13-7e549a05e897"}}}]}, {"uuid": "8111a614-f55e-4424-8ee4-434bbcae8351", "name": "load_p1rlv16247_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8d5e9b7-dc95-41f9-8547-99d5e2eba874"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6e7104d0-2c2d-41a3-9fb8-9d72be0b0dcc"}}}}, {"uuid": "9ff37076-e004-4425-a80c-3d3d8c99522d", "name": "2549db86-05ca-4352-bb29-e32892d23a92_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.398785600945231, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1157218527290627, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4613a88c-f171-4465-bc15-c79e9df82900", "name": "0c625c40-07ce-44eb-9850-e9eb6a7c6ba8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9ff37076-e004-4425-a80c-3d3d8c99522d"}}}]}, {"uuid": "9d5ffda1-a68b-4bd1-85eb-2989a2b9fb13", "name": "load_p1rlv16248_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "feb24768-feab-40f0-acc3-0b2bb500133a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4613a88c-f171-4465-bc15-c79e9df82900"}}}}, {"uuid": "0a7dc028-61ac-49b0-9e30-18f48a26ad17", "name": "807c8942-2d0d-455f-afc7-13dfc93159de_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.398785600945231, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1157218527290627, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "28bb9324-fb40-438d-a836-6880409cf4f9", "name": "fbc6768a-8fd6-4b85-a6be-605f380e2b45", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0a7dc028-61ac-49b0-9e30-18f48a26ad17"}}}]}, {"uuid": "8485dd6a-1c4a-49e3-803f-5635ffbe888b", "name": "load_p1rlv16248_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "feb24768-feab-40f0-acc3-0b2bb500133a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "28bb9324-fb40-438d-a836-6880409cf4f9"}}}}, {"uuid": "cdb85435-3309-47db-acb8-3a4839a89c95", "name": "8c0a59e0-937c-4bfb-bf0a-c0e84b341307_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c8744706-ab22-439f-abb2-6e1d0a500e5e", "name": "66c41bf8-3865-446e-a90b-1d5888d1f614", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cdb85435-3309-47db-acb8-3a4839a89c95"}}}]}, {"uuid": "ce7419eb-0876-4a0d-b3d2-2e8cc904a6ea", "name": "load_p1rlv16252_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5c6a5f39-0654-4e73-8050-c6c4ad9d54e6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c8744706-ab22-439f-abb2-6e1d0a500e5e"}}}}, {"uuid": "e477f4cc-f400-4b29-89ac-275cfab6836f", "name": "df8251ad-abb0-4b52-b0c6-32bcf56fc79f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3b142e78-a993-450e-84ba-90be31f9ed69", "name": "1312c866-677e-447c-9620-99ea07dd6e0e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e477f4cc-f400-4b29-89ac-275cfab6836f"}}}]}, {"uuid": "2350796d-9a55-42a8-9a85-fdefcd538274", "name": "load_p1rlv16252_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5c6a5f39-0654-4e73-8050-c6c4ad9d54e6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3b142e78-a993-450e-84ba-90be31f9ed69"}}}}, {"uuid": "e3b7d7a4-5f3a-41a4-b70a-5e0ec4999e4b", "name": "ee6b1bea-4ade-4e58-a2c1-0ea641f587d7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.430610855643826, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18457628630998096, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1db2a9f7-c324-4edd-9719-093ac13f48d1", "name": "0d069785-32ae-4270-b536-d1544147545c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e3b7d7a4-5f3a-41a4-b70a-5e0ec4999e4b"}}}]}, {"uuid": "33949412-5af7-4de0-9332-1bc2058e7b37", "name": "load_p1rlv16253_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "268549c6-0c8b-44ac-b933-316b36645366"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1db2a9f7-c324-4edd-9719-093ac13f48d1"}}}}, {"uuid": "53cc9afa-9837-48ce-923f-20253d4fbcf7", "name": "6f33ad52-125d-41ed-b940-d62e20895233_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.430610855643826, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18457628630998096, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9ba7469e-8d1d-4dd6-9195-589e6a163b26", "name": "e7513ceb-a589-46a9-97f8-ad86a84e318a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "53cc9afa-9837-48ce-923f-20253d4fbcf7"}}}]}, {"uuid": "74f69ee4-622b-4963-9559-731cd64ccc6a", "name": "load_p1rlv16253_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "268549c6-0c8b-44ac-b933-316b36645366"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9ba7469e-8d1d-4dd6-9195-589e6a163b26"}}}}, {"uuid": "03ab610d-cdc2-4e3e-9333-3355d230c63e", "name": "c4ca1ade-179d-432e-83aa-2c08fc697d4d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4644531671008476, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4817339405405778, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "73bc9f62-480f-46cf-afcd-8c5b94b12949", "name": "7a7f61eb-ff66-4592-b711-e8f68fb6f976", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "03ab610d-cdc2-4e3e-9333-3355d230c63e"}}}]}, {"uuid": "30737f1f-4319-4ba3-b143-efc491f42666", "name": "load_p1rlv16255_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04647fad-19dc-4ed8-8820-aa312674145c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "73bc9f62-480f-46cf-afcd-8c5b94b12949"}}}}, {"uuid": "4b23e311-7943-422d-8036-795d226c5056", "name": "4c2b9662-225b-4476-a820-ebea7dd6cd13_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4644531671008476, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4817339405405778, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9abfb742-8cbc-45c7-9c87-4371f7aaccb0", "name": "15e086d0-210c-410b-8705-47d18a32229a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4b23e311-7943-422d-8036-795d226c5056"}}}]}, {"uuid": "ed5cb148-e823-4091-ada6-468a35548c2b", "name": "load_p1rlv16255_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04647fad-19dc-4ed8-8820-aa312674145c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9abfb742-8cbc-45c7-9c87-4371f7aaccb0"}}}}, {"uuid": "b9206117-0529-4264-b73e-55b2500c05e3", "name": "ab5cd4c7-7ee7-4c21-8057-038063eaf9e2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8706127135667018, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16715860689265086, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5ea928af-bad6-4091-8dc7-75ba862f7511", "name": "bec19463-4229-4d6e-b63c-15a0450d2b4c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b9206117-0529-4264-b73e-55b2500c05e3"}}}]}, {"uuid": "7ef08658-1307-4121-8016-74f46feb38bd", "name": "load_p1rlv16256_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32a9302f-2d40-4c2a-bde9-e4039694fed7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5ea928af-bad6-4091-8dc7-75ba862f7511"}}}}, {"uuid": "4400e645-c15b-423d-a001-1fafe395d053", "name": "f9fdfbe0-2bf8-4b72-a366-e3da05e258ae_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8706127135667018, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16715860689265086, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dda8c1a5-525e-4364-af26-78e19424f467", "name": "d63cdbd6-502d-4681-99e2-a8eeb953b257", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4400e645-c15b-423d-a001-1fafe395d053"}}}]}, {"uuid": "cdeb8b48-47ad-4bf8-92c3-0363ebc6a782", "name": "load_p1rlv16256_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32a9302f-2d40-4c2a-bde9-e4039694fed7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dda8c1a5-525e-4364-af26-78e19424f467"}}}}, {"uuid": "beac4282-b4c7-4eb0-93de-2a41be630a43", "name": "925a2eb7-b2e0-46cc-b80b-bf4f2b8a93d5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5300176124233262, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6781680527999017, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d502673e-7dd3-45a6-a579-ffb9a55848f8", "name": "01ef29b7-8ff1-4800-936c-664779c361a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "beac4282-b4c7-4eb0-93de-2a41be630a43"}}}]}, {"uuid": "d28047d9-c03a-4972-8fc7-efa3a0ce86d9", "name": "load_p1rlv16257_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "935c99a6-bef6-4417-872c-0685011c440c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d502673e-7dd3-45a6-a579-ffb9a55848f8"}}}}, {"uuid": "994e5651-413a-4b97-a2b2-d5943a71cb58", "name": "828072ef-0a9d-4974-829c-5645d4bedae7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5300176124233262, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6781680527999017, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7ba5b6f2-9cab-41b0-a932-9d854bd3325b", "name": "a8b422ff-9d3e-4557-bdcd-773a89766f6f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "994e5651-413a-4b97-a2b2-d5943a71cb58"}}}]}, {"uuid": "2ba63650-a710-4e26-a30d-86e871c82e66", "name": "load_p1rlv16257_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "935c99a6-bef6-4417-872c-0685011c440c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7ba5b6f2-9cab-41b0-a932-9d854bd3325b"}}}}, {"uuid": "2f6b96cc-4721-4475-95e9-eaa8a0e85f03", "name": "63625f2b-020f-4476-9e1c-9d712ccdd87d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6722127407962883, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033140171384262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "811a9b5d-2a61-4b6c-a2e0-5ce107bc00b6", "name": "73230dbd-3733-4264-9aa6-d13e34b20755", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2f6b96cc-4721-4475-95e9-eaa8a0e85f03"}}}]}, {"uuid": "52ab00f6-292c-455d-bbba-80c1f0b5f91b", "name": "load_p1rlv16260_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdf35585-e2b3-4463-a6a8-acb352f25003"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "811a9b5d-2a61-4b6c-a2e0-5ce107bc00b6"}}}}, {"uuid": "c15b2547-d011-4db6-9d04-f1e717f0f08c", "name": "54f7a169-8b0d-47b2-8b14-27e16b6a261d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6722127407962883, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033140171384262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1af14652-b203-4f34-9074-6cdb51a10016", "name": "e9a088d2-69ef-4170-877b-8920df6b8e71", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c15b2547-d011-4db6-9d04-f1e717f0f08c"}}}]}, {"uuid": "2d908939-4308-4f5b-be72-53cc9f4d1d1e", "name": "load_p1rlv16260_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdf35585-e2b3-4463-a6a8-acb352f25003"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1af14652-b203-4f34-9074-6cdb51a10016"}}}}, {"uuid": "cc7c06ce-5557-4741-adbd-bc87cfa866a0", "name": "bb5a6a11-424e-401c-afe5-bd05c2743423_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2418080165747822, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43915934621283365, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e320a0b7-fe42-471c-8a89-4b6bdc6b5d40", "name": "362883ee-229b-4629-a632-6584f97529e5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cc7c06ce-5557-4741-adbd-bc87cfa866a0"}}}]}, {"uuid": "6842b389-cbce-4f73-840a-cc799b7336fa", "name": "load_p1rlv16261_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "978533ca-ef57-4cb6-9e7f-b3c6d1bbd7d5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e320a0b7-fe42-471c-8a89-4b6bdc6b5d40"}}}}, {"uuid": "f808bfb1-0f63-49a6-b4d7-84c408cf8403", "name": "2a7b63c6-3aa6-455e-acdc-a90973682fd4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2418080165747822, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43915934621283365, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "76000378-abb6-474c-b2ef-c9a5911ca0e0", "name": "0df3c89f-82a2-4420-9285-06a1a22b331f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f808bfb1-0f63-49a6-b4d7-84c408cf8403"}}}]}, {"uuid": "da0c47c7-3c79-431b-a175-2dcfd601d834", "name": "load_p1rlv16261_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "978533ca-ef57-4cb6-9e7f-b3c6d1bbd7d5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "76000378-abb6-474c-b2ef-c9a5911ca0e0"}}}}, {"uuid": "63fe4f3f-90de-445b-8136-d4cdd933eed8", "name": "3cffff74-ca06-4e9a-9232-7d0df38f01a8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3461402320099836, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.810674183062217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "97783810-fe85-49f2-b7b1-4af46cbb2455", "name": "3c85ce4a-02e0-4569-9661-7e6e18d6fcc6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "63fe4f3f-90de-445b-8136-d4cdd933eed8"}}}]}, {"uuid": "2478ec7b-45fe-451f-96aa-9cd41b6f9263", "name": "load_p1rlv16262_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2797febc-f5e7-4cb3-b26f-ace990dc6920"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "97783810-fe85-49f2-b7b1-4af46cbb2455"}}}}, {"uuid": "b5bd882c-07e7-4870-a1b0-72e8c0a74c42", "name": "ca1173a9-81dd-4995-b2c8-8be9f00d3b44_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3461402320099836, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.810674183062217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ad7e9c8c-0ea3-4832-aaef-b9d7c92f3ba2", "name": "0ddc8173-4d7f-46b0-91fa-215a138b9994", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5bd882c-07e7-4870-a1b0-72e8c0a74c42"}}}]}, {"uuid": "6dbd4747-2e7a-43d5-82c0-b479ca86714f", "name": "load_p1rlv16262_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2797febc-f5e7-4cb3-b26f-ace990dc6920"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ad7e9c8c-0ea3-4832-aaef-b9d7c92f3ba2"}}}}, {"uuid": "766c6dc0-d413-4dbb-a420-6b1533031cf2", "name": "7fb9e6ab-e824-4df2-a9cb-5005dcccf9b0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0052757727111112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4127143879372469, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9c4de1e6-0bd5-48b5-be95-30f7a4348c4a", "name": "a7c4d71c-995e-451f-a474-d0549dc2595b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "766c6dc0-d413-4dbb-a420-6b1533031cf2"}}}]}, {"uuid": "0219d6c8-98f6-4b98-ba29-a7464b82d3a0", "name": "load_p1rlv16266_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8835446-b333-4be9-96bd-57ff9d01ebd3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9c4de1e6-0bd5-48b5-be95-30f7a4348c4a"}}}}, {"uuid": "6dd6e2aa-1372-49e8-b910-cfe96b05329f", "name": "83b3b560-4487-470e-949c-4bba6d48ced2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0052757727111112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4127143879372469, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bfa003ca-bc4f-40f9-86c4-6a26450c4ff9", "name": "53a515c2-8ea2-459f-bea2-aca4afe2b4cc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6dd6e2aa-1372-49e8-b910-cfe96b05329f"}}}]}, {"uuid": "c786b4c3-1774-4050-8f6c-dc85c54dcd2e", "name": "load_p1rlv16266_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8835446-b333-4be9-96bd-57ff9d01ebd3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bfa003ca-bc4f-40f9-86c4-6a26450c4ff9"}}}}, {"uuid": "ac644023-aa22-402b-ace4-4f36a5673237", "name": "e670b296-ded9-440d-ab06-b3f8559514b0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.794005533851084, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6855099409421886, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "34c86588-a163-48ef-b08d-7eb6cef459c9", "name": "907ea48a-5646-4b42-92a1-dbb5541aa5db", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ac644023-aa22-402b-ace4-4f36a5673237"}}}]}, {"uuid": "499f83ff-6b0f-4a37-8418-a9a3cf315367", "name": "load_p1rlv16267_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19aeb510-ac0e-4279-8db0-8de282beccc8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "34c86588-a163-48ef-b08d-7eb6cef459c9"}}}}, {"uuid": "a80fc465-3c9d-438b-90e2-02ba863feea8", "name": "633da08d-3a5e-43ac-894b-3b2ccf0b86bf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.794005533851084, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6855099409421886, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "443427c2-6d12-4a22-b3d0-b408d981790a", "name": "17416c46-f23f-4b83-8ea4-a680905559b6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a80fc465-3c9d-438b-90e2-02ba863feea8"}}}]}, {"uuid": "127ee3f0-2b6f-46e0-953b-289dcd335a77", "name": "load_p1rlv16267_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19aeb510-ac0e-4279-8db0-8de282beccc8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "443427c2-6d12-4a22-b3d0-b408d981790a"}}}}, {"uuid": "fbe6e7b4-6025-4fac-b687-23e5575e10a1", "name": "44017a22-e3fc-440b-b8d4-7a098e0e770b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.996798907530164, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8717719006522443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a9e73675-bd7f-4896-a8ef-b46736678299", "name": "e6fc554d-c5a0-41bd-8cfc-9b4ea5d0a630", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fbe6e7b4-6025-4fac-b687-23e5575e10a1"}}}]}, {"uuid": "45761486-6e20-4090-94b4-f9d63478adc5", "name": "load_p1rlv16268_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba6ebe7f-b6b9-4f89-8bbf-7bffd63e10ef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a9e73675-bd7f-4896-a8ef-b46736678299"}}}}, {"uuid": "18caad4c-d890-448a-9ace-972ec6a6835f", "name": "5e667111-1000-4735-bc29-2f67e6a70057_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.996798907530164, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8717719006522443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dc1f1735-3f44-4f61-b875-f12cb02307da", "name": "a5de17ab-6886-4664-96b3-3b91edcb5728", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "18caad4c-d890-448a-9ace-972ec6a6835f"}}}]}, {"uuid": "ec9dbc63-2f0e-4689-9ab4-bc7d0fb48a81", "name": "load_p1rlv16268_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba6ebe7f-b6b9-4f89-8bbf-7bffd63e10ef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dc1f1735-3f44-4f61-b875-f12cb02307da"}}}}, {"uuid": "2bb55537-b3e1-4402-ae93-99f3cfc641a0", "name": "d8204634-e3fb-46cc-be88-bf688e8403ec_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.363798145332242, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4037116383567407, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "18b116f5-1ea8-404d-bac8-f2a3ef26b69b", "name": "f51befad-0132-4880-b571-049060304211", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2bb55537-b3e1-4402-ae93-99f3cfc641a0"}}}]}, {"uuid": "9bc29a80-f4ba-400b-b9d9-5db241d12b87", "name": "load_p1rlv16269_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc746539-662a-4fe4-8774-6ba2dc538118"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "18b116f5-1ea8-404d-bac8-f2a3ef26b69b"}}}}, {"uuid": "a9bcdd6a-962b-4507-947d-e42dd45d6fb1", "name": "90a80808-5225-4d5b-a3b3-22321a5f0a94_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.363798145332242, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4037116383567407, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d7b1fa47-0d96-46d5-b6cc-b9d9ecb31cec", "name": "f475d6a4-7e59-4bd1-a7d3-a45749669581", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a9bcdd6a-962b-4507-947d-e42dd45d6fb1"}}}]}, {"uuid": "4f175f3f-77a2-4b06-92d1-e3eae1b6a441", "name": "load_p1rlv16269_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc746539-662a-4fe4-8774-6ba2dc538118"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d7b1fa47-0d96-46d5-b6cc-b9d9ecb31cec"}}}}, {"uuid": "88028e8a-b39f-47f5-ae02-9827bed072f6", "name": "2a31ba10-cda3-4d2c-ad58-4118a881432a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.715296910036079, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.4546814180149177, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b8db8593-7b21-4054-b8b1-7e099912bdc2", "name": "89ed205c-4a38-46e9-afc3-163d886fe797", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "88028e8a-b39f-47f5-ae02-9827bed072f6"}}}]}, {"uuid": "858ffea9-e5e4-4ffc-9d42-b093f732e45a", "name": "load_p1rlv16270_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c620d4b9-a849-4bf6-b108-118836866602"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b8db8593-7b21-4054-b8b1-7e099912bdc2"}}}}, {"uuid": "4fb48713-2e5d-478a-8411-d43906004b3f", "name": "9fbcd029-fe06-4367-8b92-13840b382478_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.715296910036079, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.4546814180149177, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "453a6785-1ac8-404d-89d2-1428d14db38d", "name": "2ee690ab-de60-49c3-af76-f76b89005969", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4fb48713-2e5d-478a-8411-d43906004b3f"}}}]}, {"uuid": "ec15395f-4ea3-4a6d-92b1-88e1ec5f0d99", "name": "load_p1rlv16270_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c620d4b9-a849-4bf6-b108-118836866602"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "453a6785-1ac8-404d-89d2-1428d14db38d"}}}}, {"uuid": "5e911122-0db2-45dd-ac44-255e1ce2411c", "name": "03277084-12fe-4790-9668-fe8bb0eb03b1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.381399729703326, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.39528166539642545, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "32b235f2-0766-401f-8138-ad69dd2b6554", "name": "03277084-12fe-4790-9668-fe8bb0eb03b1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.381399729703326, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.39528166539642545, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fae6af08-41bc-4ece-913d-30dbceb3662d", "name": "03277084-12fe-4790-9668-fe8bb0eb03b1_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.381399729703326, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.39528166539642545, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "653f0d5d-08e0-47e1-a06d-715772f43c9d", "name": "8d7aafb3-8c0d-44f7-a78c-8cd67e83374a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5e911122-0db2-45dd-ac44-255e1ce2411c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "32b235f2-0766-401f-8138-ad69dd2b6554"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fae6af08-41bc-4ece-913d-30dbceb3662d"}}}]}, {"uuid": "d43dadee-e804-47c5-b631-82815e8ff5a5", "name": "load_p1rlv16271", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "606bf8f6-d745-4220-8cae-e01ffd22f669"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "653f0d5d-08e0-47e1-a06d-715772f43c9d"}}}}, {"uuid": "8ff3666a-1963-476c-b693-6e282e2a9e80", "name": "e2a47060-377d-427a-a38f-820686e5aa38_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.200687176070838, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9185981858680964, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f9123dcb-c7b3-422d-a8ea-8221e79caf63", "name": "0220b4c2-aa64-438f-ab3b-53e41f2f2d09", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ff3666a-1963-476c-b693-6e282e2a9e80"}}}]}, {"uuid": "031b5c59-2c52-4aec-8004-569f6c5a58d6", "name": "load_p1rlv16395_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d908890-4fe4-4349-92de-464c4165b185"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f9123dcb-c7b3-422d-a8ea-8221e79caf63"}}}}, {"uuid": "94238b3a-7fbf-4103-85a7-29eed43f218a", "name": "4e22a016-eb19-423a-bd1a-f2163e3af209_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.200687176070838, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9185981858680964, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "df08e771-7168-481a-ac9d-db1982a6beba", "name": "59f2bd06-7d04-442c-8ebd-4482658d2f47", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "94238b3a-7fbf-4103-85a7-29eed43f218a"}}}]}, {"uuid": "e193f5cd-04c5-410c-9bc1-24636b2ade55", "name": "load_p1rlv16395_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d908890-4fe4-4349-92de-464c4165b185"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "df08e771-7168-481a-ac9d-db1982a6beba"}}}}, {"uuid": "5e8f9a6c-45eb-41d2-a216-cdb7483ef44f", "name": "1566d76b-0145-466e-82c6-a75d0c430211_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.2106819008595595, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9283160881681002, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8c99023a-c460-4f29-b354-305ff8386f11", "name": "34e343f9-2dce-4c6f-9eea-d1134fa429fc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5e8f9a6c-45eb-41d2-a216-cdb7483ef44f"}}}]}, {"uuid": "78ba092a-6d63-42c4-9de8-782f0fe22265", "name": "load_p1rlv16397_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "323373a9-8e7d-4fb4-8970-dcc0e6d26c98"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8c99023a-c460-4f29-b354-305ff8386f11"}}}}, {"uuid": "63422d23-642b-4d3b-81af-4314d3fcd30a", "name": "7078de00-ecb8-4875-9964-76435221690b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.2106819008595595, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9283160881681002, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bb56652e-af5e-41f7-a9ee-946da3e3082c", "name": "98160b95-d28a-4371-a8da-a13f3b99df61", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "63422d23-642b-4d3b-81af-4314d3fcd30a"}}}]}, {"uuid": "fa96bddd-c21e-4501-99b6-78db3a2ca659", "name": "load_p1rlv16397_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "323373a9-8e7d-4fb4-8970-dcc0e6d26c98"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bb56652e-af5e-41f7-a9ee-946da3e3082c"}}}}, {"uuid": "e0b8d152-b240-434a-abe9-c4a70a2db003", "name": "38583533-e4ea-4249-8e7e-1c4ed998db82_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.920542613760824, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4990926315178331, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9e3961fc-f9f8-4891-951a-23e65d454092", "name": "a0ae2021-193a-4953-980f-f36acf97e0fd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e0b8d152-b240-434a-abe9-c4a70a2db003"}}}]}, {"uuid": "e4861e25-be6b-4ee7-8e99-6ede3986573d", "name": "load_p1rlv16401_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eeb598c2-f0b9-44df-bfaa-be66e4dc3920"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9e3961fc-f9f8-4891-951a-23e65d454092"}}}}, {"uuid": "3eb79a2e-5060-4dbc-9c72-5a4579c04793", "name": "5c536cf4-fa72-451d-be0d-a0e6fd1991be_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.920542613760824, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4990926315178331, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "895c87e5-e252-4913-a419-0644656b383d", "name": "62f3429e-8711-4c19-a7bb-3ce027f757a4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3eb79a2e-5060-4dbc-9c72-5a4579c04793"}}}]}, {"uuid": "a4fc401f-e024-44ee-bdbf-fce51a70f474", "name": "load_p1rlv16401_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eeb598c2-f0b9-44df-bfaa-be66e4dc3920"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "895c87e5-e252-4913-a419-0644656b383d"}}}}, {"uuid": "0cb39cce-8587-42be-8a63-ae3f59f5498a", "name": "eaf5cd82-120d-4055-93ae-a5c5fadd5609_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.747873943758341, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9398519580990949, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a7d066f-f450-4423-a697-67bfabe799b6", "name": "2e5625b0-4790-436b-8bf6-f13c9400d604", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0cb39cce-8587-42be-8a63-ae3f59f5498a"}}}]}, {"uuid": "972c7a59-6ae7-404e-81c7-fa45c57dfe21", "name": "load_p1rlv16412_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99f97a6b-4e94-4a35-ad00-12e7004ab5e3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0a7d066f-f450-4423-a697-67bfabe799b6"}}}}, {"uuid": "a8d982e1-2a2e-460e-883b-a181406ff941", "name": "9c75b838-e827-4110-a6bf-ef41c34de906_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.747873943758341, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9398519580990949, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dbaadde4-0d3c-44c0-b295-8e7e110e0148", "name": "1305a3ed-9851-45cb-8f23-09fdbd0d484b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a8d982e1-2a2e-460e-883b-a181406ff941"}}}]}, {"uuid": "71897fc9-f974-473a-8e44-b653f2d4c7c9", "name": "load_p1rlv16412_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99f97a6b-4e94-4a35-ad00-12e7004ab5e3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dbaadde4-0d3c-44c0-b295-8e7e110e0148"}}}}, {"uuid": "fb4a62a0-6b8b-4aa4-a292-412cd593e270", "name": "bd94fb3e-a911-4262-9c76-ea0664b61703_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9024769844937937, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4778358547008617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fd827a6d-018c-4b7a-bb2a-6ed130bd6e6e", "name": "59cdad1d-5b1e-4c9b-bfc1-512f9c41b5a2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fb4a62a0-6b8b-4aa4-a292-412cd593e270"}}}]}, {"uuid": "2ce8b856-2d26-4281-aaab-596c3aa921b1", "name": "load_p1rlv16416_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f58421d6-268b-417f-a579-c9c51d010697"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fd827a6d-018c-4b7a-bb2a-6ed130bd6e6e"}}}}, {"uuid": "39d86888-aaa7-4a94-b9ec-9444c822057c", "name": "c8dbd97e-f5f6-4daa-a313-2c40117c05c7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9024769844937937, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4778358547008617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "847117f1-9f81-41be-b42e-fd15caeb15e1", "name": "ef194679-6d04-4f0d-9bd6-d5cb958e0160", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "39d86888-aaa7-4a94-b9ec-9444c822057c"}}}]}, {"uuid": "144a5cf3-f2a4-499f-8c1d-a996c5975237", "name": "load_p1rlv16416_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f58421d6-268b-417f-a579-c9c51d010697"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "847117f1-9f81-41be-b42e-fd15caeb15e1"}}}}, {"uuid": "b5b3d6cf-cf26-41b1-92fa-2c00a700f522", "name": "e3c3d445-ec7d-4307-a035-29b44e2cffc9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.100297733607771, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.379845362785626, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "48234896-3c26-4383-bf9c-7bb1d6ccc698", "name": "d661ec93-2b74-4ca4-acae-c25a38675b40", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5b3d6cf-cf26-41b1-92fa-2c00a700f522"}}}]}, {"uuid": "50b75eea-371d-414e-84a7-a37d6213dc2f", "name": "load_p1rlv16422_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f367b63c-c4cb-4810-a270-8bd0153b7b32"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "48234896-3c26-4383-bf9c-7bb1d6ccc698"}}}}, {"uuid": "f76aa752-5d3c-4be3-8a2d-1fabc5243c2c", "name": "674f99af-8538-4b59-ab83-3a7769bc1e72_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.100297733607771, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.379845362785626, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7cfa42c3-e840-422f-80a5-74b8ec5dde7b", "name": "da5a56e2-0034-4629-8766-d31f5dbcf160", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f76aa752-5d3c-4be3-8a2d-1fabc5243c2c"}}}]}, {"uuid": "84ee1d2a-1808-4c42-b6ba-45fe48465d3e", "name": "load_p1rlv16422_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f367b63c-c4cb-4810-a270-8bd0153b7b32"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7cfa42c3-e840-422f-80a5-74b8ec5dde7b"}}}}, {"uuid": "acb00d95-db2f-40e8-beb1-a4e8a45da78d", "name": "b4cdad6e-5ab2-4a57-ab7e-e4f723888a64_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7146312183983485, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.11264482158049681, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "be571320-8f57-4664-9bb6-d56b2d52f5a2", "name": "13c3ce49-f12c-4cf8-bdad-35c19c524a2a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "acb00d95-db2f-40e8-beb1-a4e8a45da78d"}}}]}, {"uuid": "545bdbcc-1bb9-4d47-88c5-63387a19ba86", "name": "load_p1rlv16424_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2242f1c-542f-4c1f-b3e6-19482cccde8d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "be571320-8f57-4664-9bb6-d56b2d52f5a2"}}}}, {"uuid": "ddbcc4d0-063e-42c3-aed6-33dbcc9717b4", "name": "6301a0e2-3050-41f1-82f2-e9b469ea8890_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7146312183983485, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.11264482158049681, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "de5e16e3-2362-49da-8da5-dd4fab6e1d8f", "name": "a907226d-90ca-4a98-b898-33882224f3d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ddbcc4d0-063e-42c3-aed6-33dbcc9717b4"}}}]}, {"uuid": "ca76d76a-35c5-4ce5-bb21-a6c2111d97f8", "name": "load_p1rlv16424_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2242f1c-542f-4c1f-b3e6-19482cccde8d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "de5e16e3-2362-49da-8da5-dd4fab6e1d8f"}}}}, {"uuid": "0957b252-5e47-41f7-b6a2-e6577b17d3ce", "name": "bc925ba2-7d8a-4708-b132-5ece3fa00e87_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.793928923123666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.7667648924934154, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "60d2dcc2-e172-4041-abfb-5298882919e7", "name": "5d0b074a-5d1c-4241-a268-95c5b2571918", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0957b252-5e47-41f7-b6a2-e6577b17d3ce"}}}]}, {"uuid": "ed7f906d-4b9f-4f83-8d0a-58f61acbdb93", "name": "load_p1rlv16445_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e090544-3c8e-4716-9dae-0b311a1017ea"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "60d2dcc2-e172-4041-abfb-5298882919e7"}}}}, {"uuid": "883d160b-99e7-4ffd-8b68-43ee7cb47fea", "name": "4426ee03-4e04-42bf-93e1-5f2e1c49824f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.793928923123666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.7667648924934154, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "55dfe357-873c-47e5-ab06-37d5c04becd5", "name": "921d10ba-5e6b-49f7-b86e-1cd9aa75fb05", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "883d160b-99e7-4ffd-8b68-43ee7cb47fea"}}}]}, {"uuid": "1e183d4f-b8fd-497d-a0ad-f733ce506ce7", "name": "load_p1rlv16445_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e090544-3c8e-4716-9dae-0b311a1017ea"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "55dfe357-873c-47e5-ab06-37d5c04becd5"}}}}, {"uuid": "5a211146-e012-456c-acc9-8cc008eca9a0", "name": "3e340988-092c-4bf0-884c-e6848c72bdba_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5124251878637117, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2529156883724651, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "23ee6240-dfad-4b00-9260-13fe18d5afeb", "name": "c47a35b0-fcfc-44d7-ad74-1fce01a4fee3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5a211146-e012-456c-acc9-8cc008eca9a0"}}}]}, {"uuid": "f8f20623-08e0-49eb-8fd4-80a55e1449e2", "name": "load_p1rlv16570_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53d578d8-8492-471b-8f66-233e489a3652"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "23ee6240-dfad-4b00-9260-13fe18d5afeb"}}}}, {"uuid": "e6193a80-06aa-4c97-bb3a-f13e1fa7f569", "name": "2e814c98-0b7a-40b2-bfd4-cfbb60c0e567_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5124251878637117, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2529156883724651, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d87b565f-a5cf-4cb5-ac56-00d16fe1fba6", "name": "806e10c4-878d-48c1-b69f-077aed7b90ab", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e6193a80-06aa-4c97-bb3a-f13e1fa7f569"}}}]}, {"uuid": "8c31522e-cd10-4472-9fa2-5b897e757d1c", "name": "load_p1rlv16570_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53d578d8-8492-471b-8f66-233e489a3652"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d87b565f-a5cf-4cb5-ac56-00d16fe1fba6"}}}}, {"uuid": "4306f62f-dad2-4a33-bc8d-b31aaa97026e", "name": "1ab8d14c-2283-4cd0-ba17-80293c683a51_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9337862827800336, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34425772205755256, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cb6a0dc7-444c-4267-956a-8b9390366a6c", "name": "ad737204-4fee-40ca-a2c2-99bd4fb6f4d0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4306f62f-dad2-4a33-bc8d-b31aaa97026e"}}}]}, {"uuid": "13635ed1-a73b-4dc9-994c-9462be78e2f2", "name": "load_p1rlv16882_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4faf40b9-9ade-45b5-ade8-3f1833605cd1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cb6a0dc7-444c-4267-956a-8b9390366a6c"}}}}, {"uuid": "5bcd5511-2529-4eb7-8457-f438d0ac891c", "name": "11edd1eb-b4c5-453c-88e0-6f85e656d400_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9337862827800336, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34425772205755256, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bedbef98-fe52-4764-884c-77bb39d1915b", "name": "2d845e5b-b7bc-441a-80ac-faf2ef20b6fa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5bcd5511-2529-4eb7-8457-f438d0ac891c"}}}]}, {"uuid": "fe9e25b6-5829-4ee2-95d3-fc3be395fe81", "name": "load_p1rlv16882_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4faf40b9-9ade-45b5-ade8-3f1833605cd1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bedbef98-fe52-4764-884c-77bb39d1915b"}}}}, {"uuid": "67097ee4-b9be-4d31-9082-f7cf66ee0049", "name": "7e3c2e38-0f54-4726-8760-d92e4426f3d5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7142625617629952, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4166771141877461, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "14d97bf2-c194-4d47-a769-752dcc747f0f", "name": "5a6eaf75-f71b-43c8-ac57-516d27edcc59", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "67097ee4-b9be-4d31-9082-f7cf66ee0049"}}}]}, {"uuid": "8b5cf97f-791d-48cb-ad48-c2d8996a3bb1", "name": "load_p1rlv16904_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c570ef7-c483-4c1e-b0fd-8712e8e9a7cd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "14d97bf2-c194-4d47-a769-752dcc747f0f"}}}}, {"uuid": "e4e83eb7-f622-4640-af52-46e1d50e9da0", "name": "9a014efa-0f29-42bb-aca3-cb1ecfc50a01_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7142625617629952, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4166771141877461, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8af8e30a-1df0-4b5e-a815-a5afb6dbceb1", "name": "4e8548d9-9864-4a11-ae5f-66f3b465cc8b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e4e83eb7-f622-4640-af52-46e1d50e9da0"}}}]}, {"uuid": "857cf48e-9845-4a5a-bf80-2ceb844a67c1", "name": "load_p1rlv16904_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c570ef7-c483-4c1e-b0fd-8712e8e9a7cd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8af8e30a-1df0-4b5e-a815-a5afb6dbceb1"}}}}, {"uuid": "df222f2e-23dd-468f-abac-32289594b03b", "name": "f655d0ce-0bc4-45c4-bb49-ab4042a2ba9e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9815403167210675, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24442739866112323, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bc3ab1a5-9b77-46b0-9f7c-253a91bd57d3", "name": "bae5a9cd-a7ea-4ee4-9283-9944acb0cd4d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "df222f2e-23dd-468f-abac-32289594b03b"}}}]}, {"uuid": "d4a1993f-3687-4bac-b090-3ff6435c1d4e", "name": "load_p1rlv16905_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7578563f-d4b3-423b-a8f5-3ee91a042d19"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bc3ab1a5-9b77-46b0-9f7c-253a91bd57d3"}}}}, {"uuid": "fa94f8b3-d59f-46a5-a6bb-e9b83759f5cc", "name": "b3c28b6d-786a-4772-9800-eea955d5fc28_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9815403167210675, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24442739866112323, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "694a5d1c-d56c-47f4-b69f-6da3db4ec8cb", "name": "8f57c6a1-5078-4d04-9e2a-232279038f1a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fa94f8b3-d59f-46a5-a6bb-e9b83759f5cc"}}}]}, {"uuid": "a91940b7-1c3f-47c8-93b0-e337ac5fb2d4", "name": "load_p1rlv16905_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7578563f-d4b3-423b-a8f5-3ee91a042d19"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "694a5d1c-d56c-47f4-b69f-6da3db4ec8cb"}}}}, {"uuid": "866ee746-a9bb-4d9c-ac8d-b42925c2c936", "name": "16d64a28-9219-4b9e-8f02-0912ba526235_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1343287185333217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10429894918818222, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d281b117-2cfb-4d45-8fed-08e1d7ffcf94", "name": "a81c35a6-347a-4126-a0e4-f8d300079da2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "866ee746-a9bb-4d9c-ac8d-b42925c2c936"}}}]}, {"uuid": "ad5a7f1b-50a3-44c6-9f2c-ea3d4ba82a5c", "name": "load_p1rlv16912_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2308dc3-d10b-4049-862d-caf3356fa9a7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d281b117-2cfb-4d45-8fed-08e1d7ffcf94"}}}}, {"uuid": "44ebafdb-92a3-4071-b231-b704f0339e29", "name": "3a39d6e5-1381-45d2-a9fc-0ad7b0f1f80f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1343287185333217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10429894918818222, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "185703fc-cf0d-4f5b-b80f-56147a287127", "name": "952ebf46-a3d9-4ca9-b4e1-f01b4ce8a248", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "44ebafdb-92a3-4071-b231-b704f0339e29"}}}]}, {"uuid": "fd6e366d-3ed9-4ed3-ad86-5d5dab393117", "name": "load_p1rlv16912_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2308dc3-d10b-4049-862d-caf3356fa9a7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "185703fc-cf0d-4f5b-b80f-56147a287127"}}}}, {"uuid": "73edb9fc-934c-47f0-9015-56196051abfa", "name": "b74a2985-70da-447e-8ac4-c0bd47dea132_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2143639459232007, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7122713279236396, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4710cb21-5f36-4516-ac1e-c0d9f0c0ef39", "name": "53f178ef-52ba-47fa-b976-d30d5d10ccbe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "73edb9fc-934c-47f0-9015-56196051abfa"}}}]}, {"uuid": "43230887-62aa-439a-85e3-abc02603d949", "name": "load_p1rlv16919_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07e01053-37f3-4b9f-a9f1-d51bccd29803"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4710cb21-5f36-4516-ac1e-c0d9f0c0ef39"}}}}, {"uuid": "86d6c8a3-2319-4a32-a922-c9ac44d610dd", "name": "318b9101-6f0f-4353-b5c1-8a27537eef2b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2143639459232007, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7122713279236396, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "919cfc31-0be3-4208-bf84-58b3309fc292", "name": "1b4463c8-f9b7-4cfb-90a3-709b2892605d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "86d6c8a3-2319-4a32-a922-c9ac44d610dd"}}}]}, {"uuid": "a3d23238-a2d4-4e9e-8634-ebbb3d8e4a49", "name": "load_p1rlv16919_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07e01053-37f3-4b9f-a9f1-d51bccd29803"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "919cfc31-0be3-4208-bf84-58b3309fc292"}}}}, {"uuid": "90d19537-202e-4e99-9cdf-927be743f348", "name": "7f3a53b7-4837-4378-a8e1-fc886f275bc3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.639612501586281, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0977377571892493, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ae8b7549-b9c4-42b7-b6aa-eecd7bb1aa64", "name": "c645099e-0bfa-4f86-a6b3-d9b7c7a32c74", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "90d19537-202e-4e99-9cdf-927be743f348"}}}]}, {"uuid": "357d6e7d-d014-4950-8144-fd7502b9f6de", "name": "load_p1rlv16922_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce315d98-1556-429b-aebb-0c868892396a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ae8b7549-b9c4-42b7-b6aa-eecd7bb1aa64"}}}}, {"uuid": "f035a725-f539-40d0-b933-6da8edcb77d5", "name": "d0cf8fdd-fa68-49a4-8977-cf240c7ad71d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.639612501586281, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0977377571892493, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e643043d-ffbf-476a-ac58-ece88d41d61b", "name": "b31151a5-91b8-4e1d-93b7-31bbd6026038", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f035a725-f539-40d0-b933-6da8edcb77d5"}}}]}, {"uuid": "b40d9973-ff90-40bc-81dc-47776eb3ec4d", "name": "load_p1rlv16922_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce315d98-1556-429b-aebb-0c868892396a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e643043d-ffbf-476a-ac58-ece88d41d61b"}}}}, {"uuid": "269e746a-750e-4682-a328-d6112a6b4c81", "name": "a1e2c112-06a4-43cd-8c40-d406276e9962_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8791002615066037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24190904367644575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d77d41b1-5754-48bd-a7e9-50f52f40292b", "name": "94f922d3-6550-4f04-a21f-e2607de92a1a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "269e746a-750e-4682-a328-d6112a6b4c81"}}}]}, {"uuid": "3bf281d4-9ac9-4acf-9a5b-40552c83d5aa", "name": "load_p1rlv16926_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ba1d053-4462-4eb4-aca6-5ede38aa283c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d77d41b1-5754-48bd-a7e9-50f52f40292b"}}}}, {"uuid": "c1f34f7a-2f15-42c3-b742-defc4351a6d7", "name": "e8c1986b-032b-42ac-970b-c9e7d2f39d4f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8791002615066037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24190904367644575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8e73e7fb-0082-427b-bd92-3eab59da11f8", "name": "3b75e35b-133f-42a5-959b-c9303ca23409", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c1f34f7a-2f15-42c3-b742-defc4351a6d7"}}}]}, {"uuid": "c6019ae8-df4a-41f0-97a2-855d85873f24", "name": "load_p1rlv16926_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ba1d053-4462-4eb4-aca6-5ede38aa283c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8e73e7fb-0082-427b-bd92-3eab59da11f8"}}}}, {"uuid": "e4798d07-13c7-4501-b729-ce5eda382096", "name": "78e0bede-b943-41f4-bae9-36cc1b941ed1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.618088489787842, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20923793518521916, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c1a46fd4-dc1f-4a50-921e-34cb0e661c0a", "name": "a477015b-a6b4-4d59-8118-6409d2d5163a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e4798d07-13c7-4501-b729-ce5eda382096"}}}]}, {"uuid": "d25e070f-7ee8-4373-901d-635190d93b31", "name": "load_p1rlv16957_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7dff1455-5154-429f-a33f-044d8501281d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c1a46fd4-dc1f-4a50-921e-34cb0e661c0a"}}}}, {"uuid": "f4578af1-d2ff-4d34-aeb0-e1f28782f43a", "name": "a8087e06-51a4-4993-be20-3a0a57beb633_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.618088489787842, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20923793518521916, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9318be11-995a-4a84-8c1b-fdec953d1314", "name": "bc987390-8d02-46bb-96c3-abc5e3303f43", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f4578af1-d2ff-4d34-aeb0-e1f28782f43a"}}}]}, {"uuid": "b2bfe792-092e-441f-9a3f-1dc753a5797c", "name": "load_p1rlv16957_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7dff1455-5154-429f-a33f-044d8501281d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9318be11-995a-4a84-8c1b-fdec953d1314"}}}}, {"uuid": "820bf4c1-a84c-44fc-bc19-11ed37eede7a", "name": "b21a5757-7bac-4856-9a9c-fc91a7957da8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.625738069985529, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4783299291729874, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ae2df8a9-90b4-4937-8ba7-7d29299cf81a", "name": "1bbaf78b-e251-4fb1-b435-eeb6c539182c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "820bf4c1-a84c-44fc-bc19-11ed37eede7a"}}}]}, {"uuid": "c8dc1e85-f14e-49ac-8c5b-575e8bd62139", "name": "load_p1rlv16988_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11a633b0-2b09-4c66-94d4-d1c24cdd9cf5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ae2df8a9-90b4-4937-8ba7-7d29299cf81a"}}}}, {"uuid": "4fa90c01-ad5c-46ea-9b67-f1f85fb22042", "name": "63dc0f2c-4e69-4774-ae09-76780325d50b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.625738069985529, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4783299291729874, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ce4e0397-bcde-4b5f-8f7d-ce18e8885f2f", "name": "97149d3e-e2d8-419c-be96-c1abb64771c0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4fa90c01-ad5c-46ea-9b67-f1f85fb22042"}}}]}, {"uuid": "7a3dccae-2afa-4b23-b00a-910ae9ee1e94", "name": "load_p1rlv16988_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11a633b0-2b09-4c66-94d4-d1c24cdd9cf5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ce4e0397-bcde-4b5f-8f7d-ce18e8885f2f"}}}}, {"uuid": "4e5f4c5a-680a-4f82-9034-36b07c8af7df", "name": "b885c838-d5dd-401e-ab5b-f72e6a9b3074_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.857442654178314, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2722739314206026, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "70e96277-938a-41c9-872a-8953540c78f5", "name": "ea7d936e-d128-4341-a104-320475c1e68b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4e5f4c5a-680a-4f82-9034-36b07c8af7df"}}}]}, {"uuid": "0779aa7d-23e6-469b-bb88-25f2c5129f2f", "name": "load_p1rlv16992_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57e8aa34-3967-4f22-a978-cb513c49c153"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "70e96277-938a-41c9-872a-8953540c78f5"}}}}, {"uuid": "06636b1d-a342-42c8-8bd7-c49a0ab471d8", "name": "166da0d3-69b9-4e6c-90d7-1000d285d483_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.857442654178314, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2722739314206026, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "518e716f-a60e-4234-b173-d798f3671506", "name": "ab9fd947-c1b8-4877-a6eb-1c2f4401f41f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "06636b1d-a342-42c8-8bd7-c49a0ab471d8"}}}]}, {"uuid": "5bc1200b-19a4-4abd-ba8a-00031764829e", "name": "load_p1rlv16992_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57e8aa34-3967-4f22-a978-cb513c49c153"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "518e716f-a60e-4234-b173-d798f3671506"}}}}, {"uuid": "611fc267-7aa7-4bd8-8a31-aa63454e8e6c", "name": "fc502c9f-1d0c-4059-8f4c-88cd04fc680a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.5934418714018275, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3543697694181257, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "226fb417-254c-4e53-a5be-e88fa31856ff", "name": "0f9c2336-ba2c-4fe5-a661-2f9548ed1a65", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "611fc267-7aa7-4bd8-8a31-aa63454e8e6c"}}}]}, {"uuid": "7d3dd409-551e-4f07-a551-c0f615947d75", "name": "load_p1rlv17001_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f23214ee-3032-4403-9084-8117e89cb1cf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "226fb417-254c-4e53-a5be-e88fa31856ff"}}}}, {"uuid": "5c9d54af-9d15-445e-a04b-4b145ad9f1d8", "name": "5b9f9520-e11b-4645-b326-179d276830e7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.5934418714018275, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3543697694181257, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "30f29dcc-36bf-448b-8a1a-d8548da4f9ad", "name": "28b1e0c3-9834-405c-a87f-2705fc391994", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5c9d54af-9d15-445e-a04b-4b145ad9f1d8"}}}]}, {"uuid": "0310305e-5c68-4087-9f9c-31846d771f30", "name": "load_p1rlv17001_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f23214ee-3032-4403-9084-8117e89cb1cf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "30f29dcc-36bf-448b-8a1a-d8548da4f9ad"}}}}, {"uuid": "df4178c3-55ce-4da9-9e72-0d46e025bcfb", "name": "f7ccd451-931b-4ad7-86d7-540ffdf4d7f1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4585094523583652, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.19519922093662737, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "05dbd0b9-81d8-43a3-8b26-a8d014421a8e", "name": "e289882a-20f6-4105-93ed-2b41595bc8e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "df4178c3-55ce-4da9-9e72-0d46e025bcfb"}}}]}, {"uuid": "c7872ad2-77a0-4783-a58a-0014484bc2fd", "name": "load_p1rlv17028_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "213e6d98-ad57-4034-b2d0-4b096554cac2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "05dbd0b9-81d8-43a3-8b26-a8d014421a8e"}}}}, {"uuid": "9691ae32-fcce-4a5d-b7f9-2e0fd069df12", "name": "990c2f2a-51fa-4f7e-9be8-63cd80dfc8eb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4585094523583652, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.19519922093662737, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f5dbb8ee-a3ac-45d5-8565-cb868d8dcacc", "name": "2e596eab-4423-44c3-bfcd-fe7eab956605", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9691ae32-fcce-4a5d-b7f9-2e0fd069df12"}}}]}, {"uuid": "5118ee7c-01df-439c-8062-4621c59ad19d", "name": "load_p1rlv17028_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "213e6d98-ad57-4034-b2d0-4b096554cac2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f5dbb8ee-a3ac-45d5-8565-cb868d8dcacc"}}}}, {"uuid": "1075be6b-e219-473d-9788-5f8402ae986e", "name": "bc79087e-5b48-4f36-9565-0f6d889bf24a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3439175585507637, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8866404836608991, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b96068ac-8105-447b-87cc-d2dcd76627e9", "name": "c457924a-fe6c-41c2-8832-7e0dc9f8d167", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1075be6b-e219-473d-9788-5f8402ae986e"}}}]}, {"uuid": "de3a713a-805a-4f59-becb-1cf5a6bbf5bc", "name": "load_p1rlv17033_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfa28657-cd8e-4700-a189-83e021f77bee"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b96068ac-8105-447b-87cc-d2dcd76627e9"}}}}, {"uuid": "2b1955b1-62bc-4564-8fe6-35dd39d88f5b", "name": "aa89ade7-79fb-43ce-8080-59b9f57aaa03_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3439175585507637, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8866404836608991, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7b42fd45-8da2-44d9-8b3e-fcb8e439a5d7", "name": "c8b90da3-b732-4357-bb28-78406c91eb32", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2b1955b1-62bc-4564-8fe6-35dd39d88f5b"}}}]}, {"uuid": "abb1148b-4003-47e2-ac8c-b32e08454fca", "name": "load_p1rlv17033_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfa28657-cd8e-4700-a189-83e021f77bee"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7b42fd45-8da2-44d9-8b3e-fcb8e439a5d7"}}}}, {"uuid": "17e5dbaa-c769-4f03-b356-192bf295035c", "name": "191cfe11-c72d-45aa-a247-60bed4ebb772_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7956093485713416, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7629429667228578, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d53f386f-2df8-408d-9e51-aff2cce29ac9", "name": "e265aef2-bb12-431c-92b3-2353267e0ac9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "17e5dbaa-c769-4f03-b356-192bf295035c"}}}]}, {"uuid": "1002f375-c3f6-45cf-b9b1-cc1a38a48e60", "name": "load_p1rlv17059_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "92aff718-b70f-4ea4-b38b-fae69a470c58"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d53f386f-2df8-408d-9e51-aff2cce29ac9"}}}}, {"uuid": "f94714fc-b314-4c3b-a711-f8834d368c24", "name": "dc84c758-bc43-4d6e-8462-d0abdf0f5e91_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7956093485713416, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7629429667228578, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "845cf96b-513d-4834-8ba3-17f15390fbea", "name": "c47f2ca8-56e9-4890-bbe9-6a4ddf9cf345", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f94714fc-b314-4c3b-a711-f8834d368c24"}}}]}, {"uuid": "ffdaa977-c02b-4879-b639-18cc117150d5", "name": "load_p1rlv17059_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "92aff718-b70f-4ea4-b38b-fae69a470c58"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "845cf96b-513d-4834-8ba3-17f15390fbea"}}}}, {"uuid": "770ec631-db34-4b22-a286-0fe45386701a", "name": "352c6d36-cef7-4877-a5a5-ec706ac1b8aa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.969457727539003, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.134389471891055, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "70d017a7-e7af-4d32-a9ae-897881641612", "name": "02b55e58-5a28-4d94-be7a-8c095ffa4eb6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "770ec631-db34-4b22-a286-0fe45386701a"}}}]}, {"uuid": "d95d2f6f-c70e-4459-a852-b572c68f28be", "name": "load_p1rlv17063_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19130741-0fe1-4a12-8a55-96355609bccb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "70d017a7-e7af-4d32-a9ae-897881641612"}}}}, {"uuid": "e6f2358b-ab56-4521-bcd1-15842e7b60ed", "name": "e79d1d03-c7e9-4c3b-b406-1223c85893ee_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.969457727539003, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.134389471891055, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a79830b3-943c-443d-a83d-447940d123f8", "name": "a4593dd7-d942-489a-8b71-eb99f9f1c908", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e6f2358b-ab56-4521-bcd1-15842e7b60ed"}}}]}, {"uuid": "bd0c6050-31cd-4e76-be8f-e483919759fd", "name": "load_p1rlv17063_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19130741-0fe1-4a12-8a55-96355609bccb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a79830b3-943c-443d-a83d-447940d123f8"}}}}, {"uuid": "33fe1973-a21a-4bc8-a818-d2c6639e7533", "name": "714f5256-64f5-4ab0-9b88-7cc020a3ccc9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.922263051512463, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2402658775286277, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a2d73a08-0e8b-4a47-a01e-a4f6632a470b", "name": "c2a74168-1a0f-4204-b165-0b081563d7b0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "33fe1973-a21a-4bc8-a818-d2c6639e7533"}}}]}, {"uuid": "f7903183-a52b-4683-8bad-4d0773ce9007", "name": "load_p1rlv17069_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd48a076-5f8f-426a-b294-183700d1a123"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a2d73a08-0e8b-4a47-a01e-a4f6632a470b"}}}}, {"uuid": "4c5af2eb-8b35-4734-9ad2-817b3ccb6d3b", "name": "70c41a48-a083-4243-ab1d-5fd668ee1edb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.922263051512463, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2402658775286277, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5a08b7b6-26cd-4f5b-a3ef-7ad7476b292e", "name": "f6d0aaa9-95e7-47e3-bf15-8b5ba3ce733e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4c5af2eb-8b35-4734-9ad2-817b3ccb6d3b"}}}]}, {"uuid": "f578c8c4-fa8b-4d9e-9f07-4c804ebfbc3f", "name": "load_p1rlv17069_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd48a076-5f8f-426a-b294-183700d1a123"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5a08b7b6-26cd-4f5b-a3ef-7ad7476b292e"}}}}, {"uuid": "51f7d4f2-a266-4996-b80f-15338891adf1", "name": "1d06895b-42d8-4db3-8829-f756b36c3c76_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5365841293045384, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.535303100231416, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a0d7f2db-b0fe-45ca-8542-f5eedcbeab49", "name": "9de10aa4-24d6-4bf3-9b8a-57d7aa0b9870", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "51f7d4f2-a266-4996-b80f-15338891adf1"}}}]}, {"uuid": "c9d48c81-6c8c-490f-95dd-1ce2d8a0ae45", "name": "load_p1rlv17106_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5439f343-8176-4d92-99d4-bb9209817f6b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a0d7f2db-b0fe-45ca-8542-f5eedcbeab49"}}}}, {"uuid": "20a98f1d-cf86-4461-a79d-c2dc156064c9", "name": "21ab1c11-8243-4bec-8fd0-3e7c7fd1de67_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5365841293045384, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.535303100231416, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6d94ddb0-3dbb-4efe-acff-dfb997f912cd", "name": "12fe9e74-038d-4364-9813-9f3e5ad55a03", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "20a98f1d-cf86-4461-a79d-c2dc156064c9"}}}]}, {"uuid": "50ad8a88-7520-4cdc-ba7d-ff0d57068c1c", "name": "load_p1rlv17106_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5439f343-8176-4d92-99d4-bb9209817f6b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6d94ddb0-3dbb-4efe-acff-dfb997f912cd"}}}}, {"uuid": "8b36242e-6bd4-47a0-9b19-7bb52e4578f9", "name": "9cb374a1-06ea-4585-bed0-445caf08d05e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2874196130666418, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9219654181970236, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f6e11f36-1899-48eb-96e7-39b8e13aa53b", "name": "f1c45f95-14b0-4fe5-9278-4a588750554a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8b36242e-6bd4-47a0-9b19-7bb52e4578f9"}}}]}, {"uuid": "565a8900-809c-4de8-b22c-475b29b2a605", "name": "load_p1rlv17319_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9778ed5-f0c0-44de-b0d4-60659a54fa3b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f6e11f36-1899-48eb-96e7-39b8e13aa53b"}}}}, {"uuid": "ec253a61-eec6-4c57-9c65-7249402675e7", "name": "e5099b75-2916-449c-8052-583f32c20b53_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2874196130666418, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9219654181970236, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e1f66be1-8a64-4033-a446-a9cc4fd4d9c6", "name": "70dce794-59c9-46b4-a978-c63bcdd5170d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ec253a61-eec6-4c57-9c65-7249402675e7"}}}]}, {"uuid": "cf9a64fa-bfdf-49fd-9f95-5e01a1c9fb3b", "name": "load_p1rlv17319_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9778ed5-f0c0-44de-b0d4-60659a54fa3b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e1f66be1-8a64-4033-a446-a9cc4fd4d9c6"}}}}, {"uuid": "09753040-0e6b-4a7d-a2b7-32b34a52ae43", "name": "2c09bf7e-ea77-4ef0-8287-7831413ec4c3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.685213211371405, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7584354740780123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a6a57f47-e0a0-4271-bb83-ecadd10e445b", "name": "114d8058-bcfa-4ee0-b269-3af3608c887d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "09753040-0e6b-4a7d-a2b7-32b34a52ae43"}}}]}, {"uuid": "b8cc302b-3bc8-4b2e-8269-f92fa01fa7c1", "name": "load_p1rlv17320_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79991b02-c0f1-4b9b-a55e-e9b4ff7c17d9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a6a57f47-e0a0-4271-bb83-ecadd10e445b"}}}}, {"uuid": "1339bbd1-699a-457b-86a0-9548e35bffc5", "name": "448ee8a0-22e7-4fe1-803c-4b11107f1619_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.685213211371405, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7584354740780123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "657035af-f4c6-4e4a-9f57-3089797e7891", "name": "2b655e73-8a0e-402c-984b-80f6099048e2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1339bbd1-699a-457b-86a0-9548e35bffc5"}}}]}, {"uuid": "c7144a5c-c9bb-4a10-bd62-2874b0420620", "name": "load_p1rlv17320_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79991b02-c0f1-4b9b-a55e-e9b4ff7c17d9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "657035af-f4c6-4e4a-9f57-3089797e7891"}}}}, {"uuid": "d4da6f6f-0243-45bf-93a6-017baa6f7913", "name": "f760ccd8-5c94-4f50-b4f4-915c44375080_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.651721747239447, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.750976002130125, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0837056c-39b6-4fdb-8d38-7dbdb9184762", "name": "df662db3-42c8-4c75-8d37-5391bef3944e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d4da6f6f-0243-45bf-93a6-017baa6f7913"}}}]}, {"uuid": "239d1bff-f9a1-4edc-bc72-e064e2f577c4", "name": "load_p1rlv17321_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce41ac7c-06c5-435a-957d-c9dda83c1893"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0837056c-39b6-4fdb-8d38-7dbdb9184762"}}}}, {"uuid": "37295526-b584-45ad-92f9-39939c9a4ebf", "name": "a74f6ab6-e8f9-4028-8cf2-8b6085846259_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.651721747239447, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.750976002130125, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c7f44cb0-11c8-4f88-9771-59efe5287350", "name": "e5470d52-e1cb-4b55-973e-749cfe5b1e86", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "37295526-b584-45ad-92f9-39939c9a4ebf"}}}]}, {"uuid": "1b3480aa-cbb6-4442-a899-573ac7b41435", "name": "load_p1rlv17321_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce41ac7c-06c5-435a-957d-c9dda83c1893"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c7f44cb0-11c8-4f88-9771-59efe5287350"}}}}, {"uuid": "235d75c4-2295-44ab-8df0-5cd891f92385", "name": "7e97fd9b-b041-41f6-ae16-1532d47e3390_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.737986692242784, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8906640815201406, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "903aae3b-fcbc-44bf-8758-2d1c89fe8b18", "name": "61bd174e-2446-48ac-a280-97adb323c08d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "235d75c4-2295-44ab-8df0-5cd891f92385"}}}]}, {"uuid": "1535ffaa-5001-4f52-8f80-2852bafe92ad", "name": "load_p1rlv17325_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b96606c-9336-4299-be8d-295c84943a9d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "903aae3b-fcbc-44bf-8758-2d1c89fe8b18"}}}}, {"uuid": "d0a83ebe-9d26-4422-a27d-d362ea0d2275", "name": "15f958a3-c7c3-47b4-9e02-9681fef221f7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.737986692242784, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8906640815201406, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6881f547-3f6e-4678-83c3-557c9ad34cfd", "name": "36aa2e1a-aabb-49f5-b74b-8dd8cb98a9ae", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d0a83ebe-9d26-4422-a27d-d362ea0d2275"}}}]}, {"uuid": "4970ad7b-7fdc-4b8e-a6d9-fb76fc0b981c", "name": "load_p1rlv17325_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b96606c-9336-4299-be8d-295c84943a9d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6881f547-3f6e-4678-83c3-557c9ad34cfd"}}}}, {"uuid": "f8cd7541-9f9c-4029-9050-ac9ae9981b61", "name": "3dd2dcda-5b20-4521-9e1c-533b0f4e2d7d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6912886909314806, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4972799611827758, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ef49f829-a2f1-487a-92ae-0a19154aead2", "name": "a1cb7b13-e07d-4b3a-b665-a622a752c384", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8cd7541-9f9c-4029-9050-ac9ae9981b61"}}}]}, {"uuid": "e86268fa-8ad4-49fe-8411-13873c95c5c1", "name": "load_p1rlv17326_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ceb2d77-2da7-44df-9f28-69ed35835775"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ef49f829-a2f1-487a-92ae-0a19154aead2"}}}}, {"uuid": "cf2f9671-7166-4bed-b0e5-cdfe1a3e3407", "name": "b001c8e1-fbe3-4315-9012-5d7b53544280_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6912886909314806, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4972799611827758, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d12cd93b-3287-4394-ad01-9fe19d458e21", "name": "4194c18c-2067-4de4-a9b2-b7305de03e5d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cf2f9671-7166-4bed-b0e5-cdfe1a3e3407"}}}]}, {"uuid": "04c053de-c88f-429f-8ab5-3ded39fef042", "name": "load_p1rlv17326_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ceb2d77-2da7-44df-9f28-69ed35835775"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d12cd93b-3287-4394-ad01-9fe19d458e21"}}}}, {"uuid": "dcad649d-8185-48c6-b750-d5f463a7a21f", "name": "f871a1d5-2c75-44b5-9c2b-723355efeb26_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8996652652050283, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6342298940221502, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f010069f-ea35-4345-9daa-b8507cb0699f", "name": "ebbd0d99-b2f3-4e55-be22-f03e43cb34d0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dcad649d-8185-48c6-b750-d5f463a7a21f"}}}]}, {"uuid": "af64a22c-b338-4f1d-99e4-adc3f6ce48cd", "name": "load_p1rlv17328_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a43eb022-d5e0-47c8-aa36-6ca0d212ab07"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f010069f-ea35-4345-9daa-b8507cb0699f"}}}}, {"uuid": "33b5235b-19af-4e31-8616-eeb491886df0", "name": "59a7faed-ede4-4c0c-8cd0-53d4d59b4b4b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8996652652050283, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6342298940221502, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "362f1e4e-e82c-4263-ad7a-1736626d9256", "name": "a3751d2c-9cb4-4c6e-8aa2-9609fffb808c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "33b5235b-19af-4e31-8616-eeb491886df0"}}}]}, {"uuid": "a5b20244-ff63-44b8-8128-e65520ab9992", "name": "load_p1rlv17328_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a43eb022-d5e0-47c8-aa36-6ca0d212ab07"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "362f1e4e-e82c-4263-ad7a-1736626d9256"}}}}, {"uuid": "502af279-7eef-4cd6-bc11-335a2d01c6a6", "name": "23f5e75d-4b35-4623-8af6-52bc6d890237_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.965154260277072, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307595255595673, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "03e0b75d-f196-4789-b772-0d0bfcdd7467", "name": "05f90df4-2094-4b44-bcff-622bcb412f47", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "502af279-7eef-4cd6-bc11-335a2d01c6a6"}}}]}, {"uuid": "421c3101-a04f-42d9-8430-d2215058afef", "name": "load_p1rlv17329_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61ef37c1-f14f-4b79-a428-d51a6f0d076a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "03e0b75d-f196-4789-b772-0d0bfcdd7467"}}}}, {"uuid": "bf4e7f5c-06b7-48c3-917d-f780ba6569af", "name": "2c20c9c8-ab35-439c-95b8-88a2bec362ee_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.965154260277072, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307595255595673, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4a990b69-4720-4896-a637-88307f139368", "name": "1c6d8545-b014-47e2-b39c-5c9b64403991", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bf4e7f5c-06b7-48c3-917d-f780ba6569af"}}}]}, {"uuid": "2d364ee8-89df-47d3-925d-bc76de773f9f", "name": "load_p1rlv17329_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61ef37c1-f14f-4b79-a428-d51a6f0d076a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4a990b69-4720-4896-a637-88307f139368"}}}}, {"uuid": "73300fee-aac5-4356-8768-a4c425db1b5c", "name": "d1e15fa3-2da0-4791-91b5-615a9f354c5c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.356365911619733, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.9144830945937485, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f87347ec-7156-4651-b922-6d73776421c8", "name": "b99d852e-feb2-4e27-bfa0-3d0a37d1b68f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "73300fee-aac5-4356-8768-a4c425db1b5c"}}}]}, {"uuid": "e33a1b8c-05d1-4e88-aea1-642e6a4b9283", "name": "load_p1rlv17330_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48ad7bb0-8dd7-457a-b77d-6db2071c2fe7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f87347ec-7156-4651-b922-6d73776421c8"}}}}, {"uuid": "e730a872-297b-4984-9f32-ea11e1223742", "name": "bd4c8eca-463f-417e-ad06-5b4f0592da20_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.356365911619733, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.9144830945937485, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "521fd1db-d248-4a5c-837d-8765dbe26545", "name": "de103423-d263-4bc4-8e5f-616aef1079b5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e730a872-297b-4984-9f32-ea11e1223742"}}}]}, {"uuid": "d780e515-74d8-40c6-a7b7-c9071c69af6d", "name": "load_p1rlv17330_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48ad7bb0-8dd7-457a-b77d-6db2071c2fe7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "521fd1db-d248-4a5c-837d-8765dbe26545"}}}}, {"uuid": "1bfcde87-02bf-4ce9-8ed4-7209cb2e19d7", "name": "0295af67-ecd0-486b-af5e-69d9a5cdfe46_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.255903801273714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9789336651099453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "80309df0-588d-49c0-ad64-99b3de9933af", "name": "e0617d38-b588-4c31-9ee1-be55b341fb67", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1bfcde87-02bf-4ce9-8ed4-7209cb2e19d7"}}}]}, {"uuid": "366eed2b-9cc7-4cc8-9a6d-f23d8620b83d", "name": "load_p1rlv17333_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33b66eb9-3b21-4f92-b19b-6a0eef4134d8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "80309df0-588d-49c0-ad64-99b3de9933af"}}}}, {"uuid": "6ae4fcd8-c7f9-45bb-aac8-956b026448cc", "name": "cff104dd-acb7-4b9a-91d7-e355b76ea6b7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.255903801273714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9789336651099453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "abf2ae54-b1d6-4d72-a05f-98f931da19aa", "name": "bd7f4c86-5f03-4e9d-a761-526843704029", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6ae4fcd8-c7f9-45bb-aac8-956b026448cc"}}}]}, {"uuid": "b58c0573-6035-407e-b046-33984fd2092c", "name": "load_p1rlv17333_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33b66eb9-3b21-4f92-b19b-6a0eef4134d8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "abf2ae54-b1d6-4d72-a05f-98f931da19aa"}}}}, {"uuid": "38389ae1-540a-4b72-aa42-af02254ae37f", "name": "657c8f54-5aaa-4854-8bec-9057bdcd69c8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4460841500077097, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.15562665537022718, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dee75f5a-8383-4ed1-9bcb-b2bcf07eb44c", "name": "5f368daa-20fb-4310-ab20-38e603dd0dda", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "38389ae1-540a-4b72-aa42-af02254ae37f"}}}]}, {"uuid": "76335f13-60ce-41e1-9026-922a1d9ecad6", "name": "load_p1rlv17334_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4970bc03-bc57-4a42-b0cb-66002af1709e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dee75f5a-8383-4ed1-9bcb-b2bcf07eb44c"}}}}, {"uuid": "7f4ebfe0-40c5-4bc9-8d1b-595aba889280", "name": "d1f4d03d-b29c-4558-a26c-8a63b1703fbb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4460841500077097, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.15562665537022718, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f40e8fbd-f09a-4cdc-8726-aadbe95b7361", "name": "9e000e2d-2767-4d2f-9a5a-ebc1aace4bc6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7f4ebfe0-40c5-4bc9-8d1b-595aba889280"}}}]}, {"uuid": "4f7252ce-8e0f-41f4-ae5f-1e75102a5f20", "name": "load_p1rlv17334_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4970bc03-bc57-4a42-b0cb-66002af1709e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f40e8fbd-f09a-4cdc-8726-aadbe95b7361"}}}}, {"uuid": "7770234d-62d4-4e13-93b8-9faa62388024", "name": "4c0ed79f-20c9-4da8-9fc7-9b40e54ee282_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.359977223622412, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2969054470018346, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d1ccdca0-093d-4453-a542-dfb77fd0c26f", "name": "735ac888-54bc-4df2-8549-bcd8f865f7ae", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7770234d-62d4-4e13-93b8-9faa62388024"}}}]}, {"uuid": "d7fc5468-3384-4827-b882-e6713879f684", "name": "load_p1rlv17336_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b645969-9136-42a9-b5ac-7d2f1ff71959"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d1ccdca0-093d-4453-a542-dfb77fd0c26f"}}}}, {"uuid": "bc11a223-15f9-48b8-b73b-8370380bc9fd", "name": "19cfeaa7-2b0c-4f67-ac42-d0300df652fb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.359977223622412, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2969054470018346, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e69fe531-0740-4468-9fe7-288bd3769e5f", "name": "5ff19b73-e67a-42e3-9192-f3a4f27649df", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bc11a223-15f9-48b8-b73b-8370380bc9fd"}}}]}, {"uuid": "8396bf77-6765-45f5-82e9-242a84e70f48", "name": "load_p1rlv17336_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b645969-9136-42a9-b5ac-7d2f1ff71959"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e69fe531-0740-4468-9fe7-288bd3769e5f"}}}}, {"uuid": "0f8feaae-af20-4ec3-8b23-e952cb4a6d6e", "name": "83159870-f9d3-442a-97aa-8a42631c32f5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.157838539018536, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.1846823736377714, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "98bd2f16-26b5-47f5-87b1-b3b75c6eb722", "name": "b53c729d-dc99-403d-9bfb-61ee0f06c0ac", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0f8feaae-af20-4ec3-8b23-e952cb4a6d6e"}}}]}, {"uuid": "6e1b9ad7-c909-4865-8432-e7ff483d75c1", "name": "load_p1rlv17337_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5d7049e-9d30-474c-9033-3ad9b4487f7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "98bd2f16-26b5-47f5-87b1-b3b75c6eb722"}}}}, {"uuid": "23ea3d41-4fb0-400f-b006-de183516f61c", "name": "b9274f04-6d81-4bdc-b6b4-9d251c80c79f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.157838539018536, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.1846823736377714, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5e6a5815-3cb1-4b23-9e57-d203e5d85c62", "name": "97315a0a-6423-4943-9a7c-8b41539a03cb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "23ea3d41-4fb0-400f-b006-de183516f61c"}}}]}, {"uuid": "684f5533-f848-4fe6-afd9-8445ebb46174", "name": "load_p1rlv17337_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5d7049e-9d30-474c-9033-3ad9b4487f7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5e6a5815-3cb1-4b23-9e57-d203e5d85c62"}}}}, {"uuid": "5c054edd-c1ec-4d63-b7fd-2207354a66cc", "name": "0b5b75ef-8e44-46a6-a040-396856a4ca71_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.241859724602562, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.250877899038581, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "62397ab6-6a05-426d-8dc3-584c053fff44", "name": "883f491d-1400-4a65-a1fa-92903e5d220f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5c054edd-c1ec-4d63-b7fd-2207354a66cc"}}}]}, {"uuid": "f32efdb4-559e-490e-b395-2486691c556e", "name": "load_p1rlv17338_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "331389ab-5d04-4648-83b4-3043198c774f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "62397ab6-6a05-426d-8dc3-584c053fff44"}}}}, {"uuid": "69d97f87-0ce5-4dad-84fe-c0820689c482", "name": "5c9344f5-ed54-4a4e-9556-05651f149697_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.241859724602562, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.250877899038581, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bdd66b0e-efdd-4dbb-a880-a563704bab7f", "name": "dc6d0468-96f6-4234-8881-da3ca3c8a732", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "69d97f87-0ce5-4dad-84fe-c0820689c482"}}}]}, {"uuid": "24b04968-809c-4f9e-82c9-2393f24ced06", "name": "load_p1rlv17338_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "331389ab-5d04-4648-83b4-3043198c774f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bdd66b0e-efdd-4dbb-a880-a563704bab7f"}}}}, {"uuid": "7d6f6682-4b16-4d78-8341-02dff6a588fe", "name": "5fcda203-655d-453f-95e9-d856be4dda50_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.949137985829372, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.575540256876006, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e10dccc6-c7b1-47cd-88f9-ba4e865bb912", "name": "349bdcdc-edbb-489d-acac-32c5c19e07d2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7d6f6682-4b16-4d78-8341-02dff6a588fe"}}}]}, {"uuid": "72c9ade7-113c-41e7-9225-8cff048b643b", "name": "load_p1rlv17702_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7acb4e7d-cb06-4848-952d-7c68bb34b6db"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e10dccc6-c7b1-47cd-88f9-ba4e865bb912"}}}}, {"uuid": "be52c1ba-3322-4d4f-a639-ed481cdafb06", "name": "1c903b5f-69b3-4a5f-826c-408a365c6bd8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.949137985829372, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.575540256876006, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "450b1b56-3277-4891-bb72-afcc79768b33", "name": "2789a382-ddb9-43ab-bc92-aec08e51abb1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "be52c1ba-3322-4d4f-a639-ed481cdafb06"}}}]}, {"uuid": "5fc87cb6-ada6-4067-b553-daebcf1caece", "name": "load_p1rlv17702_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7acb4e7d-cb06-4848-952d-7c68bb34b6db"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "450b1b56-3277-4891-bb72-afcc79768b33"}}}}, {"uuid": "54432679-b6b2-4d78-ab72-45c674f6e4c7", "name": "cbff83cc-f4cb-4058-a0fc-21d41805ea63_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.965154260277072, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307595255595673, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b029dfda-8738-4211-924a-5b1ccf2b13c9", "name": "e0b5bc66-cdee-4562-9a95-1f343869399a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "54432679-b6b2-4d78-ab72-45c674f6e4c7"}}}]}, {"uuid": "f405c86c-6283-4e82-94df-f7684c805921", "name": "load_p1rlv17781_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a52db2ff-b782-40c1-828a-c65f6929b2fc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b029dfda-8738-4211-924a-5b1ccf2b13c9"}}}}, {"uuid": "1e999895-719f-4b49-b2c7-7a104578adb6", "name": "8bc0e0ee-ff40-4d1e-baee-9f86e3507dbf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.965154260277072, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307595255595673, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2079d6c3-7144-4c92-bc10-aeffc20e685f", "name": "9a9e85ad-5a1d-44fb-b0e2-22b93b6b85b5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1e999895-719f-4b49-b2c7-7a104578adb6"}}}]}, {"uuid": "a61d4b03-911d-42f1-9f8d-c407beccdbeb", "name": "load_p1rlv17781_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a52db2ff-b782-40c1-828a-c65f6929b2fc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2079d6c3-7144-4c92-bc10-aeffc20e685f"}}}}, {"uuid": "3d87410e-83fa-4503-a32b-42bffa2ade70", "name": "9ebe8467-6d47-4b96-aa2a-cc848e2cf97e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.4509454152189125, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9978822313633423, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "198a11c5-9d1e-4caf-a3fd-831192a81b57", "name": "846dcd18-3cee-466e-83b5-1959f08516b3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3d87410e-83fa-4503-a32b-42bffa2ade70"}}}]}, {"uuid": "48206521-093e-4330-82af-1b8be5c79b02", "name": "load_p1rlv17787_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c9c1d9f-eeff-454f-b3d0-7e7de837694c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "198a11c5-9d1e-4caf-a3fd-831192a81b57"}}}}, {"uuid": "163ec51c-f0c1-492c-9666-21946210daaf", "name": "29b335a2-eaf9-48da-817a-17d7c348ac1d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.4509454152189125, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9978822313633423, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8058e3d1-c5b1-4e29-bd83-99287167a6c4", "name": "e1e33dda-f889-4d56-993e-273a46436294", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "163ec51c-f0c1-492c-9666-21946210daaf"}}}]}, {"uuid": "a7bfce45-0f3d-4e66-b3ea-051b6d8c0cf3", "name": "load_p1rlv17787_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c9c1d9f-eeff-454f-b3d0-7e7de837694c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8058e3d1-c5b1-4e29-bd83-99287167a6c4"}}}}, {"uuid": "7b857081-2d81-4bc4-a793-593d6a41b721", "name": "69e968b9-c607-4afc-8481-09a084bce421_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8534881847076217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.812795269620709, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0adc15f9-14b0-4e0c-b445-d886b5f3c16e", "name": "a0a04716-5d5d-4c1e-aa2b-43c7fad31167", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b857081-2d81-4bc4-a793-593d6a41b721"}}}]}, {"uuid": "78c99f01-deb9-4359-9ee0-bb0448e0955b", "name": "load_p1rlv17798_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9dba02d-086c-4906-9c6f-86532e3384c0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0adc15f9-14b0-4e0c-b445-d886b5f3c16e"}}}}, {"uuid": "8555fc92-e9ab-4ffe-b86c-713c278c23fb", "name": "ac94db1f-9834-4f23-8a46-337a25965209_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8534881847076217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.812795269620709, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0cc910e3-3490-41d8-bbf8-a3487362ef2d", "name": "4a6c21e0-2ca4-442d-8d28-1b9ffe7f3dcf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8555fc92-e9ab-4ffe-b86c-713c278c23fb"}}}]}, {"uuid": "aa5c1c56-5a37-4ada-9466-b39ca4a4ea34", "name": "load_p1rlv17798_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9dba02d-086c-4906-9c6f-86532e3384c0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0cc910e3-3490-41d8-bbf8-a3487362ef2d"}}}}, {"uuid": "5f9ef80b-6b91-445d-a78e-777ec0e81b50", "name": "f92c31a2-9402-4e54-9e0f-1de381a81ec1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6844632506969115, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4071315730781585, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d7df6801-627e-4f73-ad3d-f2e3d628eff9", "name": "9efd73ab-497f-47f0-8980-6551b60ee625", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5f9ef80b-6b91-445d-a78e-777ec0e81b50"}}}]}, {"uuid": "3f9bdf0e-f89f-46e9-a0d2-587640eb27bc", "name": "load_p1rlv17810_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3887a879-0783-4703-8a24-32b7e3b4f39d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d7df6801-627e-4f73-ad3d-f2e3d628eff9"}}}}, {"uuid": "14d19e97-d917-49f8-8726-06d23e6a61f8", "name": "58baa9eb-f123-4e37-8b30-8735fcd7f441_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6844632506969115, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4071315730781585, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "445ea327-9707-4c4e-b794-9288514689f9", "name": "52f7ab9d-9e50-48b6-81f3-75cd2228557b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "14d19e97-d917-49f8-8726-06d23e6a61f8"}}}]}, {"uuid": "2f28be03-818a-4f93-af62-e804e4f8052b", "name": "load_p1rlv17810_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3887a879-0783-4703-8a24-32b7e3b4f39d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "445ea327-9707-4c4e-b794-9288514689f9"}}}}, {"uuid": "e14a7e0c-44e6-4636-9145-5902e8696f58", "name": "3454769d-7d63-4a7f-9fe0-6062947119bf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.136651452497737, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.586908988148888, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "25e771ac-e957-447e-8569-3b5b9a12e970", "name": "5674eef4-41c9-43f4-bbe8-54b74a5533d8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e14a7e0c-44e6-4636-9145-5902e8696f58"}}}]}, {"uuid": "c72a25b6-0826-41ad-a0d8-f7b0c4265083", "name": "load_p1rlv17847_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f7776e4-a81f-48d2-b3c0-d70bfa48164e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "25e771ac-e957-447e-8569-3b5b9a12e970"}}}}, {"uuid": "4cf6afae-55af-4626-8b4e-7dbefc832603", "name": "330a397d-5aff-4cbf-aff8-b9fcc9e7f79f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.136651452497737, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.586908988148888, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "35baf397-b50d-4e62-9f61-77b4a7ea8418", "name": "444cc47d-e24e-4637-85d4-6a37566cd207", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4cf6afae-55af-4626-8b4e-7dbefc832603"}}}]}, {"uuid": "eee5393e-00d6-46c7-b18b-a0f91f0d99fe", "name": "load_p1rlv17847_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f7776e4-a81f-48d2-b3c0-d70bfa48164e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "35baf397-b50d-4e62-9f61-77b4a7ea8418"}}}}, {"uuid": "6e098042-e93f-4831-8ac8-ae75c7f70985", "name": "ef62be26-4c67-45c8-99db-2e14e7c2275b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3135149757913545, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7371070877725675, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7a47240f-01a4-41ee-b4b9-72dc87b5daec", "name": "ceca9648-b1df-47a9-9014-80d9e01f1dd8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6e098042-e93f-4831-8ac8-ae75c7f70985"}}}]}, {"uuid": "5498629b-d009-4516-acf5-664b97cf89c2", "name": "load_p1rlv17857_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0827675c-2467-403d-822e-5f74cd6296c5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7a47240f-01a4-41ee-b4b9-72dc87b5daec"}}}}, {"uuid": "a47d8cd3-ed11-4b5f-9db3-c4a0034a9ca4", "name": "fb659191-f009-41b2-b21f-120fa0247c8f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3135149757913545, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7371070877725675, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fca87ce0-49b3-4835-820a-8be2bcae6903", "name": "251ff752-b29c-40ce-bba4-4314bc46db73", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a47d8cd3-ed11-4b5f-9db3-c4a0034a9ca4"}}}]}, {"uuid": "c858a7f0-8223-4efb-a2d9-b2882fb6d971", "name": "load_p1rlv17857_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0827675c-2467-403d-822e-5f74cd6296c5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fca87ce0-49b3-4835-820a-8be2bcae6903"}}}}, {"uuid": "785da82f-5373-452b-8227-90ab120ca7b4", "name": "56bf38fa-cd89-4dbe-8b53-49af2e32ed1f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.443583112785006, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2576306570382033, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fef70936-b654-42b2-be1b-86b55a67b30a", "name": "79526ef0-8a1f-4b6e-843f-8bb1698ea65f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "785da82f-5373-452b-8227-90ab120ca7b4"}}}]}, {"uuid": "a4d5dbc3-0330-411d-8a82-6a7737083b0e", "name": "load_p1rlv17876_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75e55237-b847-4fb7-a141-a0771bd868c6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fef70936-b654-42b2-be1b-86b55a67b30a"}}}}, {"uuid": "1e9a1961-e7a9-4146-80c2-cf66003e17ba", "name": "72125487-3fd7-4146-bfb6-029c8fb66e97_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.443583112785006, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2576306570382033, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b1747e1a-b340-4027-b5b4-cdc0451196ad", "name": "66e84d45-331d-4185-a59d-2323e03033d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1e9a1961-e7a9-4146-80c2-cf66003e17ba"}}}]}, {"uuid": "57dc88b8-3fa0-4d70-9b9e-b9d84be074a7", "name": "load_p1rlv17876_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75e55237-b847-4fb7-a141-a0771bd868c6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b1747e1a-b340-4027-b5b4-cdc0451196ad"}}}}, {"uuid": "2a816c78-b7c5-4dae-86bc-556d575808b4", "name": "f8759381-73dd-4b2d-9110-80d5e846c70e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1426015471760884, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5928311844731246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cc7bc10a-874e-4459-af46-b5b0f7ad1bc6", "name": "93601803-22d6-4ad7-bb7d-e7211b2a59ff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2a816c78-b7c5-4dae-86bc-556d575808b4"}}}]}, {"uuid": "7a66ce02-8f45-4802-ae36-c25ff587b520", "name": "load_p1rlv17877_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f44b0293-61e5-4054-b2d7-4a113df92b3c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cc7bc10a-874e-4459-af46-b5b0f7ad1bc6"}}}}, {"uuid": "0c3e0615-8667-4df0-b786-134737220183", "name": "e87fd7ce-4d9e-463c-8d0a-3c500e9b8401_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1426015471760884, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5928311844731246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2efdaf05-7c0b-491c-9674-03bc78329797", "name": "f88041bf-92ed-424b-820b-e0481e549c88", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0c3e0615-8667-4df0-b786-134737220183"}}}]}, {"uuid": "613a4a65-8be2-4936-a8bd-f65d054605f7", "name": "load_p1rlv17877_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f44b0293-61e5-4054-b2d7-4a113df92b3c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2efdaf05-7c0b-491c-9674-03bc78329797"}}}}, {"uuid": "747c2cc6-2d86-4f59-9ca8-530bb0f6ba8d", "name": "46b5cdf4-3ff2-4a1c-bef2-2d57a001d3ef_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.67620786252276, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6753067705079763, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0af8c976-a6e0-4470-bc59-1d8800943c1a", "name": "1d4b0369-7042-401d-a28a-16884ca6b2c7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "747c2cc6-2d86-4f59-9ca8-530bb0f6ba8d"}}}]}, {"uuid": "e3f310df-f0c4-4b89-9432-0bab91f2241d", "name": "load_p1rlv17897_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f74f217-4765-406d-9646-d8f46377ef0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0af8c976-a6e0-4470-bc59-1d8800943c1a"}}}}, {"uuid": "0c405577-dccd-493a-bd4b-e52011412b9e", "name": "deab8b54-668c-47ff-8a8c-9d158ba82837_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.67620786252276, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6753067705079763, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c33af26c-c73a-4bf3-8252-dd6b48f69ce1", "name": "bd9a4bb0-985a-4626-9645-2d8b3c4c0fec", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0c405577-dccd-493a-bd4b-e52011412b9e"}}}]}, {"uuid": "3ac79b34-2d50-40be-baa0-efbb85f6253d", "name": "load_p1rlv17897_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f74f217-4765-406d-9646-d8f46377ef0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c33af26c-c73a-4bf3-8252-dd6b48f69ce1"}}}}, {"uuid": "673954b0-f374-4cea-81d2-77aae21ac239", "name": "c7ca9f33-6dee-4b99-ab2e-c6fd7b8f141c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3841896439528762, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.62886585412856, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "43870935-1fbe-4419-a912-eabaf277738d", "name": "1f44b787-71df-4d82-892f-ed486384c677", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "673954b0-f374-4cea-81d2-77aae21ac239"}}}]}, {"uuid": "f146f258-d046-4e2f-92cf-fa17ae5d53a8", "name": "load_p1rlv17909_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab733d49-bb36-4631-8824-1967f98f758a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "43870935-1fbe-4419-a912-eabaf277738d"}}}}, {"uuid": "b0f16155-341f-4fef-9b89-4ba76fa3fa9b", "name": "184ed837-46d1-48b6-9e40-41454e4f4529_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3841896439528762, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.62886585412856, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0cc76fc8-659e-45fa-8c82-49735e94aa6e", "name": "756b0c1d-4183-4f16-93fb-62c0a6c14c1b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b0f16155-341f-4fef-9b89-4ba76fa3fa9b"}}}]}, {"uuid": "8b089298-c576-4ac5-8380-4d3a995dd365", "name": "load_p1rlv17909_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab733d49-bb36-4631-8824-1967f98f758a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0cc76fc8-659e-45fa-8c82-49735e94aa6e"}}}}, {"uuid": "85580e6f-4336-4378-8593-aa5e7f997af6", "name": "c78d97da-dbb2-40cc-a767-670b78cef609_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5290895920961123, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.36247808422876804, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "737497c3-2c01-4ab2-a5db-da56979d37c2", "name": "ab66c99b-9660-48d5-a102-d31d5ad73bc4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "85580e6f-4336-4378-8593-aa5e7f997af6"}}}]}, {"uuid": "554a2fbd-8de1-491f-9962-641362d00fec", "name": "load_p1rlv17912_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3eb66d3-0271-4842-8893-9a58f64e0279"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "737497c3-2c01-4ab2-a5db-da56979d37c2"}}}}, {"uuid": "35e16783-6c79-4cb2-8388-75a45ee8381c", "name": "27882881-f8f6-46ab-afa3-e2c94a85c378_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5290895920961123, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.36247808422876804, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "32cacb6c-cb9e-4d0b-bb0b-6ecc9421fcf1", "name": "2b39f0f8-eee4-4971-9ef8-b5929d463593", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "35e16783-6c79-4cb2-8388-75a45ee8381c"}}}]}, {"uuid": "ab4939ac-f9c6-4ce9-9625-94b0d4bcd5dc", "name": "load_p1rlv17912_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3eb66d3-0271-4842-8893-9a58f64e0279"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "32cacb6c-cb9e-4d0b-bb0b-6ecc9421fcf1"}}}}, {"uuid": "f121e983-b923-4500-a667-b0c458477d72", "name": "c4c3ef96-98c9-4de0-87a3-17dba1f39788_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.53872088738556, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0484090155056416, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "58b14df9-08c0-4c7d-8ffc-c69eb560f186", "name": "7454fbd0-0e55-4473-851a-edf12b088e6e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f121e983-b923-4500-a667-b0c458477d72"}}}]}, {"uuid": "72a62921-b6d9-4e38-948d-caef55f4832f", "name": "load_p1rlv17926_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2812bbb1-0bb0-499f-a394-0995784bb7bc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "58b14df9-08c0-4c7d-8ffc-c69eb560f186"}}}}, {"uuid": "c9d24559-cd5e-43ad-b30e-90aa7792fc53", "name": "467c2215-dde7-4a09-a503-571ccf8670c0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.53872088738556, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0484090155056416, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "873ca082-8d2a-4bbd-b64a-200399a7fa2e", "name": "ba080ed0-a082-40d1-870d-4cd6e9d28483", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9d24559-cd5e-43ad-b30e-90aa7792fc53"}}}]}, {"uuid": "dfa5b295-8bae-42f3-bac4-7cbd34dbd9b5", "name": "load_p1rlv17926_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2812bbb1-0bb0-499f-a394-0995784bb7bc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "873ca082-8d2a-4bbd-b64a-200399a7fa2e"}}}}, {"uuid": "a51df733-a1a0-44c8-b6da-4e51ae456dab", "name": "9727774c-93bc-41c4-8516-53ded346a01a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9243645178497548, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1029763549760416, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0b144409-29f3-4aae-973f-de0f15942722", "name": "f9d605d1-f989-4bbe-8d7d-3ee66c387489", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a51df733-a1a0-44c8-b6da-4e51ae456dab"}}}]}, {"uuid": "8dcabd59-b0bb-4578-9b9a-ddf3e05199bc", "name": "load_p1rlv17960_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "215a5974-e23b-46f0-bde9-f5ad16fdfaf8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0b144409-29f3-4aae-973f-de0f15942722"}}}}, {"uuid": "18d35654-eabd-48ad-b40e-e1a5f9d70b65", "name": "49f0a928-a1cd-4c63-b22d-ca6193302c0f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9243645178497548, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1029763549760416, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aed5f5f5-d1fc-428c-a25d-04a11d59a468", "name": "175c910f-8a28-4c5a-91dc-3c92d43f6a92", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "18d35654-eabd-48ad-b40e-e1a5f9d70b65"}}}]}, {"uuid": "7d94f70f-8b62-40ed-8e1a-3ef30f8baa32", "name": "load_p1rlv17960_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "215a5974-e23b-46f0-bde9-f5ad16fdfaf8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aed5f5f5-d1fc-428c-a25d-04a11d59a468"}}}}, {"uuid": "bef3716f-841e-42a0-b5c6-ad05d7d4b39e", "name": "40099928-ff6e-442e-926b-0313269e41dc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.498014754859445, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "38bf2759-9d5a-4191-81c9-7b6a88469a70", "name": "824f1227-95e5-416c-a14b-112fac6a710b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bef3716f-841e-42a0-b5c6-ad05d7d4b39e"}}}]}, {"uuid": "994236b6-d001-4192-9f84-405c6a284793", "name": "load_p1rlv17961_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2716887e-1701-4a78-805b-96da0781c7f8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "38bf2759-9d5a-4191-81c9-7b6a88469a70"}}}}, {"uuid": "e0606768-9b13-4f11-a250-4360c3e94b74", "name": "428da6b8-fa3a-4e61-9877-bb07755f3169_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.498014754859445, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dff768e5-d8c7-42b4-b30a-4e42f71261e9", "name": "9caf0ad2-af21-40a4-9e1a-a10322d5057f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e0606768-9b13-4f11-a250-4360c3e94b74"}}}]}, {"uuid": "eb5a0498-5956-4b87-9295-49e532a7dfe7", "name": "load_p1rlv17961_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2716887e-1701-4a78-805b-96da0781c7f8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dff768e5-d8c7-42b4-b30a-4e42f71261e9"}}}}, {"uuid": "9efb896d-0011-455d-b26f-581c13ab6ba1", "name": "e8f4e742-6ae7-41d1-aea6-4737074853a8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4651344294517608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7736313908316925, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1e24c802-acb4-4c9d-8e8b-82548499c030", "name": "20f50e06-ba44-4c08-a440-ac3d0c0ff194", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9efb896d-0011-455d-b26f-581c13ab6ba1"}}}]}, {"uuid": "522399a3-eb8a-4295-a203-4ad7992130ab", "name": "load_p1rlv17962_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec99daac-e0be-4ea1-ba4f-185d4943396d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1e24c802-acb4-4c9d-8e8b-82548499c030"}}}}, {"uuid": "929ca6ca-a3ce-42e9-a5e6-6a795631e22f", "name": "b3e41a9f-aa35-425f-ac89-4956de4a32e6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4651344294517608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7736313908316925, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a0ae656-44fb-451e-9ce3-335ca2aa43ad", "name": "5fd5411c-5965-4e7f-bef9-5bcb02bfb77e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "929ca6ca-a3ce-42e9-a5e6-6a795631e22f"}}}]}, {"uuid": "1cc045b5-a3a0-4869-a60f-a759e5eb16dd", "name": "load_p1rlv17962_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec99daac-e0be-4ea1-ba4f-185d4943396d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a0ae656-44fb-451e-9ce3-335ca2aa43ad"}}}}, {"uuid": "80c1306a-2395-499e-8d7b-a00ea5cbc1f5", "name": "36e9c8af-fb21-4fd7-ab9a-069eb5405324_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.107858967059457, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3651352875232526, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "575b6888-0bd4-41d2-b5c0-3b2efbd2bc27", "name": "4da172cc-66c4-41ea-a05f-8bc6c686b27a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "80c1306a-2395-499e-8d7b-a00ea5cbc1f5"}}}]}, {"uuid": "1a13d31f-dd8c-48db-9566-bb8555ff2eb6", "name": "load_p1rlv17969_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ccaf70a-35d8-4f16-b632-e282fe30b5ca"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "575b6888-0bd4-41d2-b5c0-3b2efbd2bc27"}}}}, {"uuid": "356eac4e-c227-4733-ad20-430ccd100a54", "name": "3bb91beb-def4-4ac9-837d-d19d44558d5b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.107858967059457, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3651352875232526, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4b44aed9-c5e4-43b8-850e-8d81021d55fa", "name": "c94f6aee-952d-4b57-8918-e23555512cf6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "356eac4e-c227-4733-ad20-430ccd100a54"}}}]}, {"uuid": "9bc6eff4-5e3a-4c95-9a8d-c503e9b2f022", "name": "load_p1rlv17969_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ccaf70a-35d8-4f16-b632-e282fe30b5ca"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4b44aed9-c5e4-43b8-850e-8d81021d55fa"}}}}, {"uuid": "7c8c52d7-c1da-4a84-9f8b-6da12b106261", "name": "e8394590-bd10-43e1-8be7-11875e03895a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8939358223380807, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6690937458929831, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "15f03cc3-4b5f-44ca-bf57-a3bfdbcaf20c", "name": "e884a5e6-d820-4ea9-88d5-f95975577ddd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7c8c52d7-c1da-4a84-9f8b-6da12b106261"}}}]}, {"uuid": "761d9060-9915-4396-823f-9d89270cc816", "name": "load_p1rlv17987_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0771ebfa-5eaf-4ae8-94f1-86de7a656f58"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "15f03cc3-4b5f-44ca-bf57-a3bfdbcaf20c"}}}}, {"uuid": "09143581-c632-4b97-9e2d-846f065ae568", "name": "c79622ae-1a19-4bd6-9a02-44a40c1271ed_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8939358223380807, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6690937458929831, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0770b80e-1ba4-4142-bbad-cb21fc5a7bf0", "name": "8e94e562-b508-49aa-9243-e8ee4ca25e68", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "09143581-c632-4b97-9e2d-846f065ae568"}}}]}, {"uuid": "55c4c05e-ffa0-4950-ab16-60ea16d44777", "name": "load_p1rlv17987_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0771ebfa-5eaf-4ae8-94f1-86de7a656f58"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0770b80e-1ba4-4142-bbad-cb21fc5a7bf0"}}}}, {"uuid": "7d268e87-7787-4271-8a16-4ca5cbd5b1ad", "name": "8f2eb056-9539-463c-bd7d-a24c464d0f5b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0404861968223509, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5307917165881004, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f336219e-e2ac-4bc3-a323-65e4d9edb635", "name": "c8fffeef-26c4-4fb7-a4e3-d188a91238ac", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7d268e87-7787-4271-8a16-4ca5cbd5b1ad"}}}]}, {"uuid": "c7e08a67-99af-4662-9700-745aab48ccab", "name": "load_p1rlv18044_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b40fac8c-a99b-4baa-940a-26565ba7d62b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f336219e-e2ac-4bc3-a323-65e4d9edb635"}}}}, {"uuid": "fd34ef56-f97c-4d4e-91c8-1b0e1d0d6fd7", "name": "7e460095-9f92-44b2-b8b5-9fab9d29e144_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0404861968223509, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5307917165881004, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "420f9a97-b7fc-4c97-b066-8df50a178869", "name": "329acef9-99ed-4b46-8b52-a131f586e947", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fd34ef56-f97c-4d4e-91c8-1b0e1d0d6fd7"}}}]}, {"uuid": "47e7ab04-3e9f-430e-be73-1584529a1096", "name": "load_p1rlv18044_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b40fac8c-a99b-4baa-940a-26565ba7d62b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "420f9a97-b7fc-4c97-b066-8df50a178869"}}}}, {"uuid": "5df3cb72-beb9-4ad3-b570-6d9cc60d23da", "name": "1b28d631-8654-4420-a891-23e721aae671_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.199673234956728, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.25859312667494616, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3adf9d10-fdb0-4c38-bf75-0d97ef0b4aaa", "name": "ec3d2672-b86c-4faf-9e3e-1457857bc427", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5df3cb72-beb9-4ad3-b570-6d9cc60d23da"}}}]}, {"uuid": "f12b8f76-6571-4c39-bfdd-40132252b81e", "name": "load_p1rlv18053_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4aeda1c7-41be-43c8-82e5-d7a347db86a8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3adf9d10-fdb0-4c38-bf75-0d97ef0b4aaa"}}}}, {"uuid": "79bf0340-ffdb-466c-9259-6dc5218d6227", "name": "4d063cd1-4fff-4f98-8177-f8adbb31c500_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.199673234956728, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.25859312667494616, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "60274c84-23f5-44ff-99e7-ad3b25f47512", "name": "3afce734-0a45-4eba-88ab-17b0dbd76aa7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "79bf0340-ffdb-466c-9259-6dc5218d6227"}}}]}, {"uuid": "4654b7ec-a734-477b-b98c-9cb10503571f", "name": "load_p1rlv18053_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4aeda1c7-41be-43c8-82e5-d7a347db86a8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "60274c84-23f5-44ff-99e7-ad3b25f47512"}}}}, {"uuid": "3e27d3ad-838f-4703-8e56-d400c5f8a3ce", "name": "3fcdee97-11a1-400c-b114-7c40df65b086_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7675749799903273, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6204429178040327, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "958bd145-fde9-484a-acfb-51e25fc3f9c8", "name": "ed7798d9-a2ac-41f6-b2e8-c2c2edac844e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3e27d3ad-838f-4703-8e56-d400c5f8a3ce"}}}]}, {"uuid": "88995c28-9ad6-4253-b4e5-abd41ca9e893", "name": "load_p1rlv18071_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86917829-123c-4fda-9809-dc61430a9fef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "958bd145-fde9-484a-acfb-51e25fc3f9c8"}}}}, {"uuid": "e771654a-ed9a-4ad0-b64e-2fbfa5239ffd", "name": "fa50f85a-044f-49a5-923f-a7bcddb40686_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7675749799903273, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6204429178040327, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b099b994-1dac-48a6-bafa-305c627fe7bd", "name": "34354eae-b6d8-4527-8a04-babf22ff2f34", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e771654a-ed9a-4ad0-b64e-2fbfa5239ffd"}}}]}, {"uuid": "1a472225-fbb8-44a1-b0ef-094c201ca96d", "name": "load_p1rlv18071_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86917829-123c-4fda-9809-dc61430a9fef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b099b994-1dac-48a6-bafa-305c627fe7bd"}}}}, {"uuid": "03075fc0-3dbe-4162-8d65-f42b924a9a81", "name": "cea04c29-238b-4c69-ab2d-8c7e7dd7b301_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2005170978204305, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8833048630127251, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cccf2bd5-fc9b-4b22-ad4f-6e60c8241b9b", "name": "6ca40b0d-06cc-469c-8da4-ce0f4ad063d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "03075fc0-3dbe-4162-8d65-f42b924a9a81"}}}]}, {"uuid": "28148e11-d3f7-4090-99b7-f2914a7771c7", "name": "load_p1rlv18100_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4863d28-4ee2-479d-accb-60b54f472fe7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cccf2bd5-fc9b-4b22-ad4f-6e60c8241b9b"}}}}, {"uuid": "d1cb8122-5757-430c-8855-0127ca1873f2", "name": "27c4cb99-9a24-411d-9960-24b11ac0eaec_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2005170978204305, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8833048630127251, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b05810b3-1268-45d7-9846-95cd0ad29b3c", "name": "5a0826ab-1ad9-460a-9b0c-cd7b6a386ea4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d1cb8122-5757-430c-8855-0127ca1873f2"}}}]}, {"uuid": "33841819-e3a2-4fec-a57f-b1864081f314", "name": "load_p1rlv18100_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4863d28-4ee2-479d-accb-60b54f472fe7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b05810b3-1268-45d7-9846-95cd0ad29b3c"}}}}, {"uuid": "8c72effc-f49a-4c58-ad55-22badf2f583d", "name": "2e352eb8-6201-4c37-ba59-10a9cb0eb2f3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2075389461119934, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3167249782629938, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "986789eb-fe6d-4ef7-840f-e5fcbf1e3bc0", "name": "bde6c827-9d2c-411b-a06d-3ba379010267", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8c72effc-f49a-4c58-ad55-22badf2f583d"}}}]}, {"uuid": "f2cfd818-8882-43e9-addd-e0ad44040a28", "name": "load_p1rlv18129_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "115a848f-f6f3-48f0-9f33-5a9103f1a892"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "986789eb-fe6d-4ef7-840f-e5fcbf1e3bc0"}}}}, {"uuid": "5a2ce607-31a7-40a7-8a80-162bb5787360", "name": "021e46a8-a5d4-4dc6-aa79-874afe956e42_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2075389461119934, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3167249782629938, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e9dab9c4-3f86-4dc0-bf0d-ba3fc0e13621", "name": "4569044e-ce09-49e1-9104-2878e36f1ec2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5a2ce607-31a7-40a7-8a80-162bb5787360"}}}]}, {"uuid": "4dbcd618-27f3-417a-9b1d-07e0894cd8f9", "name": "load_p1rlv18129_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "115a848f-f6f3-48f0-9f33-5a9103f1a892"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e9dab9c4-3f86-4dc0-bf0d-ba3fc0e13621"}}}}, {"uuid": "ed97d495-4878-4728-805d-f857a3a611ec", "name": "fc62f661-92ad-4639-88e3-9dca6a64180c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3268329182243828, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6606620655388332, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "12991d25-4c53-47d7-ab45-adc402c143d3", "name": "736cf412-ac15-4084-8de1-411be757913f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ed97d495-4878-4728-805d-f857a3a611ec"}}}]}, {"uuid": "f1da61cb-3884-4f89-b184-c3708d29eb39", "name": "load_p1rlv18166_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "431692e5-2917-41ea-aafc-96be180b7e27"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "12991d25-4c53-47d7-ab45-adc402c143d3"}}}}, {"uuid": "9d66f1fa-41a6-4581-ab8c-81e89618b04b", "name": "4cdb61f2-3a90-4f0c-ab4c-7a53207cf31a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3268329182243828, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6606620655388332, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d9c8f299-4954-40a4-a240-cd2adae70530", "name": "e14d0abd-926d-4b2e-83f2-6afa1fdc9b5b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9d66f1fa-41a6-4581-ab8c-81e89618b04b"}}}]}, {"uuid": "ebf7542b-7eda-4a54-ab7f-c9324bbf5e8d", "name": "load_p1rlv18166_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "431692e5-2917-41ea-aafc-96be180b7e27"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d9c8f299-4954-40a4-a240-cd2adae70530"}}}}, {"uuid": "ab46062b-f641-4da2-96c8-8c433018dd78", "name": "6972b329-1f10-4ef6-ad40-e76563e89199_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cc9487f5-2aab-43b3-992e-54f57e90d5c8", "name": "a56b133d-f339-48b0-b8e0-08351d898d96", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ab46062b-f641-4da2-96c8-8c433018dd78"}}}]}, {"uuid": "fb84b9e0-2dfe-44a9-a3f1-93c28e583a40", "name": "load_p1rlv18192_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c3e08a8-ea88-423d-b361-69509f7ab8fa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cc9487f5-2aab-43b3-992e-54f57e90d5c8"}}}}, {"uuid": "951d662a-0416-45f2-9997-c6e140565f83", "name": "45acbd5f-b7e8-46f1-a2e5-e99e1003350d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8434317b-50f4-4029-ab69-190b32871133", "name": "640917a0-312a-47c7-b00a-50b0d8a1dbf9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "951d662a-0416-45f2-9997-c6e140565f83"}}}]}, {"uuid": "2b1900a9-e3e5-4074-8d8d-25af0c96225a", "name": "load_p1rlv18192_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c3e08a8-ea88-423d-b361-69509f7ab8fa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8434317b-50f4-4029-ab69-190b32871133"}}}}, {"uuid": "b61f3f55-672b-4cad-aa77-43e4ce9bc1fc", "name": "75ffe928-d893-4390-b50f-05c00ef1ff76_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.948680292874151, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.769988963438003, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4882a0c1-919d-4da2-bc38-44888d427089", "name": "dc460813-a025-4a1b-9de4-26291cf0936d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b61f3f55-672b-4cad-aa77-43e4ce9bc1fc"}}}]}, {"uuid": "a07e8600-88ab-4422-91ff-ca68999aa185", "name": "load_p1rlv18197_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5e240e8-b27d-4181-a7ee-a004d3f5c58a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4882a0c1-919d-4da2-bc38-44888d427089"}}}}, {"uuid": "d0976f00-4aaa-4faa-9f7b-963cf6661a53", "name": "f4ed0f48-252c-4744-a8be-47521bb9e690_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.948680292874151, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.769988963438003, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9b834b4a-d6dd-458e-aa5e-c4b66586c32f", "name": "1d36f195-ab24-4b30-bc04-92e9ff7f7c9e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d0976f00-4aaa-4faa-9f7b-963cf6661a53"}}}]}, {"uuid": "e45885c7-2504-4309-9bf3-26a2709f647b", "name": "load_p1rlv18197_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5e240e8-b27d-4181-a7ee-a004d3f5c58a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9b834b4a-d6dd-458e-aa5e-c4b66586c32f"}}}}, {"uuid": "b44a5637-33ac-43e4-9b88-35bcc319c1f3", "name": "03c05035-fe62-4427-a676-da984a6bb1d9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1698158732703443, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8490689598373361, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7f7cd507-7c9d-44bc-8133-69917dbfc87c", "name": "ea4fc29e-6ff7-42a4-bb90-eab6be3af249", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b44a5637-33ac-43e4-9b88-35bcc319c1f3"}}}]}, {"uuid": "c4fbfa3b-3dc0-41e9-b442-03e16247c0a4", "name": "load_p1rlv18198_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a7cb078-af6c-4cd5-9aca-48f515f6e711"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7f7cd507-7c9d-44bc-8133-69917dbfc87c"}}}}, {"uuid": "e479fb2f-4e22-4c7a-b453-75f36c005814", "name": "50472ce7-6c1e-4b22-83fa-668d103c6d6f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1698158732703443, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8490689598373361, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f4b23009-956b-4690-aabc-ec574695bed0", "name": "69dad363-7f6e-43f7-ba5a-a1783a4cf1a8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e479fb2f-4e22-4c7a-b453-75f36c005814"}}}]}, {"uuid": "1a5ed19a-7d46-43e6-9691-6d3f55153c9f", "name": "load_p1rlv18198_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a7cb078-af6c-4cd5-9aca-48f515f6e711"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f4b23009-956b-4690-aabc-ec574695bed0"}}}}, {"uuid": "276ea94c-e3c1-4cc5-9859-3a79835d1732", "name": "7e861e6f-9889-4f20-a5da-ebcb502d6916_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1801024488747824, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6406661654566495, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "08b7b6d3-4881-4ee5-9ec6-4bfc51ec49ce", "name": "3f5ce7bc-bb23-445c-8e73-acaedd6d90a8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "276ea94c-e3c1-4cc5-9859-3a79835d1732"}}}]}, {"uuid": "299e6517-f4c9-4ce7-9581-76c2055f841a", "name": "load_p1rlv18960_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9178fdee-311f-40f5-bdd6-9b474a05247e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "08b7b6d3-4881-4ee5-9ec6-4bfc51ec49ce"}}}}, {"uuid": "72d93b5a-33ab-47bb-9adb-4ff1c9b299df", "name": "1696a9c2-4c7e-4554-aca7-0a06eb4fdd48_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1801024488747824, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6406661654566495, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "09b995d5-0033-485f-b28a-8760affaac32", "name": "464a37f8-2e6d-4d9c-bb83-37ddc44d0fab", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72d93b5a-33ab-47bb-9adb-4ff1c9b299df"}}}]}, {"uuid": "51ed28f6-fde9-4502-9bde-3b93db46f283", "name": "load_p1rlv18960_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9178fdee-311f-40f5-bdd6-9b474a05247e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "09b995d5-0033-485f-b28a-8760affaac32"}}}}, {"uuid": "899a49e6-7b69-4db2-8d09-8925b0ce3fb1", "name": "8053ebbb-7ea6-4faa-aa26-0b9f67c1feff_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2045141672666357, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3046267940472902, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "51a0facb-5b80-4fbb-9975-cb7581507496", "name": "91d20e8a-8b70-460f-b8fb-8ae972a78dc1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "899a49e6-7b69-4db2-8d09-8925b0ce3fb1"}}}]}, {"uuid": "2f8f440f-bdcc-448e-8f86-8b00ebb2acfc", "name": "load_p1rlv18967_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eef4f0cf-6e51-45e1-8b6e-84171f7cbef6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "51a0facb-5b80-4fbb-9975-cb7581507496"}}}}, {"uuid": "a725c8c0-7954-4257-9a35-a61da37a2e42", "name": "70fcedb9-cf7e-4485-9a0f-9e1e11138e2f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2045141672666357, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3046267940472902, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fe11e8fd-a436-4ca3-bd2b-cc95dca6b5fa", "name": "13bd4487-3d1d-4764-b85b-3eba9ec1eeef", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a725c8c0-7954-4257-9a35-a61da37a2e42"}}}]}, {"uuid": "9cc09d32-0935-4602-a270-cf01750eee4d", "name": "load_p1rlv18967_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eef4f0cf-6e51-45e1-8b6e-84171f7cbef6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fe11e8fd-a436-4ca3-bd2b-cc95dca6b5fa"}}}}, {"uuid": "1bc226e4-d825-48c6-b833-fe32cf0ae345", "name": "177bb8d7-148a-41b3-b2de-a89663e90700_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1222862909492073, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34523553920221683, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "125c1e25-a0ec-48cd-8e28-e7715a931e54", "name": "e722f372-88ba-4e37-8b0a-bd6dc16ffd8b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1bc226e4-d825-48c6-b833-fe32cf0ae345"}}}]}, {"uuid": "2f9a01e1-3bf0-4357-891e-89f0f5382d4b", "name": "load_p1rlv19146_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0bb184ad-cb26-4317-8c40-f2c8a9f80dab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "125c1e25-a0ec-48cd-8e28-e7715a931e54"}}}}, {"uuid": "d34e1d78-8d7c-417c-8892-0c55830d30ab", "name": "ff88758b-f910-4a31-8511-29aa0ed51445_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1222862909492073, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34523553920221683, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1ece6b38-82a3-43f4-84c9-09f1840cdf2b", "name": "a65f33d6-bdcc-4356-a949-430509372f0f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d34e1d78-8d7c-417c-8892-0c55830d30ab"}}}]}, {"uuid": "d93487e0-e966-46e0-8d01-1def495b974d", "name": "load_p1rlv19146_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0bb184ad-cb26-4317-8c40-f2c8a9f80dab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1ece6b38-82a3-43f4-84c9-09f1840cdf2b"}}}}, {"uuid": "69f7dbef-382f-4102-a948-57f2c415c946", "name": "a189b0be-1b52-4fcf-a047-5b79aafa0cb8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4868228207229564, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16976956391895093, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d130eab6-4e26-4eef-a078-d7c0b36a6ffc", "name": "90529770-274c-4c96-bb3b-977a5634b8af", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "69f7dbef-382f-4102-a948-57f2c415c946"}}}]}, {"uuid": "6e5c4f0f-df78-4714-9ce1-7d7261bf01ac", "name": "load_p1rlv19147_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "546433b3-d70e-49ed-9037-ec88adda79b9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d130eab6-4e26-4eef-a078-d7c0b36a6ffc"}}}}, {"uuid": "0a53069c-3064-4f06-872d-870fd265d2c3", "name": "6b8cac3e-b265-423f-8f4f-f24c760d8254_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4868228207229564, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16976956391895093, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "36dc5985-18ba-4e5e-9854-e0c0d806f1f2", "name": "487d7df3-d4f2-4ca3-b2f5-ddc7e6da5c1c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0a53069c-3064-4f06-872d-870fd265d2c3"}}}]}, {"uuid": "f6467e30-51e9-4a90-940c-a4135378cf12", "name": "load_p1rlv19147_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "546433b3-d70e-49ed-9037-ec88adda79b9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "36dc5985-18ba-4e5e-9854-e0c0d806f1f2"}}}}, {"uuid": "e0a27af4-c819-4cc9-9bec-a802754241a8", "name": "61c65a95-d6be-490c-865f-253fc9479b67_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "11b78b7d-430d-4a8d-bef5-0b834f29a3da", "name": "5165893a-7e75-4e7b-bb10-423a322366b4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e0a27af4-c819-4cc9-9bec-a802754241a8"}}}]}, {"uuid": "b4ee36f5-ff72-4a5a-9ce9-8298c7940304", "name": "load_p1rlv19149_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67a4600d-65c3-40d7-ad28-e8e37ff77dcb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "11b78b7d-430d-4a8d-bef5-0b834f29a3da"}}}}, {"uuid": "b126c6f7-d987-4d64-9271-4040e5e45fb2", "name": "411a8146-f899-45ca-9bf0-aab8e89c51e5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1deb3031-dd5d-4979-9be3-b3d7671c2f97", "name": "99cfbb7d-055c-4999-a3f9-841bc2001a22", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b126c6f7-d987-4d64-9271-4040e5e45fb2"}}}]}, {"uuid": "f7ecb440-0f55-4077-972a-53257e3a5828", "name": "load_p1rlv19149_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67a4600d-65c3-40d7-ad28-e8e37ff77dcb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1deb3031-dd5d-4979-9be3-b3d7671c2f97"}}}}, {"uuid": "2006ec6b-bb56-40ed-8a9f-8176087493fb", "name": "c814eae1-c780-4d8c-8f56-b953a77c46d9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9f955821-e89b-4b40-b4a1-6af5dd0b3574", "name": "8bc15210-bb12-457c-8ea0-0edd3dda432d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2006ec6b-bb56-40ed-8a9f-8176087493fb"}}}]}, {"uuid": "447a6f1f-7647-4dcf-9712-01fbb936a123", "name": "load_p1rlv19151_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e396aca-4116-40a0-8f17-bcd41f709ea5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9f955821-e89b-4b40-b4a1-6af5dd0b3574"}}}}, {"uuid": "c4fd19b7-b22f-46e5-b563-0298fb65e63c", "name": "ad996323-23ba-4d5d-b88c-159e5e2cbaaf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c137e1f1-bdbb-49ff-8f40-580b7e0f4224", "name": "ec44ced7-7c3c-4fde-b7fa-6b14d50146c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c4fd19b7-b22f-46e5-b563-0298fb65e63c"}}}]}, {"uuid": "c32a760d-f772-45ff-b58c-786f29590e79", "name": "load_p1rlv19151_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e396aca-4116-40a0-8f17-bcd41f709ea5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c137e1f1-bdbb-49ff-8f40-580b7e0f4224"}}}}, {"uuid": "c979f935-316d-4b43-8d51-0fae19c3ce1f", "name": "fa22fc25-8a81-4d5e-af8a-9ee320db2b53_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "99e06090-15dd-44ff-9d44-643acab3c309", "name": "f015c1fc-bc74-4fcb-a5c5-4c00e9b6e1a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c979f935-316d-4b43-8d51-0fae19c3ce1f"}}}]}, {"uuid": "67d5f06f-741f-4d64-8663-e91765b579ce", "name": "load_p1rlv19156_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7538ab85-10b4-4f60-98f8-179e954173b0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "99e06090-15dd-44ff-9d44-643acab3c309"}}}}, {"uuid": "63861aec-1ad6-4dff-a6b7-8e477408f934", "name": "266481a1-df1e-48ee-ab0c-e02cc76fe11c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5e21c6ee-1022-4216-8086-614971d8d0dc", "name": "bc1f8952-aa82-438a-b2de-7e231781adc7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "63861aec-1ad6-4dff-a6b7-8e477408f934"}}}]}, {"uuid": "9eccf85d-4195-48ef-b3e4-2066df60f2ca", "name": "load_p1rlv19156_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7538ab85-10b4-4f60-98f8-179e954173b0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5e21c6ee-1022-4216-8086-614971d8d0dc"}}}}, {"uuid": "ab78db94-1f0e-4dd7-83d1-9c218fb6c801", "name": "a4afcba3-8368-4025-a240-a48948785ede_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "03f0b66f-8782-437d-893c-4ab306535a7e", "name": "fd9b05bb-cd06-495e-ad6b-02b803e6ef0a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ab78db94-1f0e-4dd7-83d1-9c218fb6c801"}}}]}, {"uuid": "fb7b6520-f031-46e5-ab58-5a32c3720f76", "name": "load_p1rlv19157_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cf28b5d-d8d4-4883-a396-2d1ad9b70564"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "03f0b66f-8782-437d-893c-4ab306535a7e"}}}}, {"uuid": "4aec0a3d-5ed1-4d04-872b-4ea2c9a0270f", "name": "2b8246dc-5e8d-4877-b179-32172f58dbeb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "41a0cbe4-e162-4b07-8626-a429f97eb724", "name": "616828e3-a43b-4bd1-8729-bfc0edf8fea0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4aec0a3d-5ed1-4d04-872b-4ea2c9a0270f"}}}]}, {"uuid": "dfd1c368-60c2-4c49-a3d6-658df1829401", "name": "load_p1rlv19157_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cf28b5d-d8d4-4883-a396-2d1ad9b70564"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "41a0cbe4-e162-4b07-8626-a429f97eb724"}}}}, {"uuid": "656bb808-01e5-498d-b7e6-9d46d58c4339", "name": "e40be9cf-19b0-49f8-91cf-e7ed028086cb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cfb03cdd-df7b-4b87-835c-c55f81af6284", "name": "4b6fcb01-dac6-49ef-86a5-0aa8362e52c5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "656bb808-01e5-498d-b7e6-9d46d58c4339"}}}]}, {"uuid": "8b847b39-7e24-4032-b73b-2d85750c95c6", "name": "load_p1rlv19160_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7c1d210-ee87-46c5-b408-ad221cbeed04"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cfb03cdd-df7b-4b87-835c-c55f81af6284"}}}}, {"uuid": "204671b2-3428-47fe-846a-7027d0e70063", "name": "af954102-ced1-4ef2-aa4d-f783f34441d0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d77f185c-0a07-499e-94e4-504cda314ca5", "name": "355cf035-3998-4d46-9cef-82b52ea8b04f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "204671b2-3428-47fe-846a-7027d0e70063"}}}]}, {"uuid": "56a631ee-ab12-4070-82c8-c6afb5a609eb", "name": "load_p1rlv19160_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7c1d210-ee87-46c5-b408-ad221cbeed04"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d77f185c-0a07-499e-94e4-504cda314ca5"}}}}, {"uuid": "1257114c-fea5-441e-93ad-1e4d27afac16", "name": "5316039a-415e-4595-b908-92332fae7858_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c9e8216b-acd6-40a8-900a-1997fd54b543", "name": "a8fd5c09-0540-4cf1-96f7-2ccc4453783f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1257114c-fea5-441e-93ad-1e4d27afac16"}}}]}, {"uuid": "5e1657e0-b2a4-46b2-9af1-b71e3627f267", "name": "load_p1rlv19161_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16df6b90-d049-4160-b148-b888e03acb82"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c9e8216b-acd6-40a8-900a-1997fd54b543"}}}}, {"uuid": "29918bf7-fa41-4fc0-8435-78a1b354e19e", "name": "1dfbdde7-c939-48ca-ac88-d954a09977c3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8faaf976-ea71-4910-9243-aee1cb5d3875", "name": "90456313-14d1-4cfb-a466-8c19ad4da216", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "29918bf7-fa41-4fc0-8435-78a1b354e19e"}}}]}, {"uuid": "d570bd79-b4de-4cb4-b574-33abb71b1d14", "name": "load_p1rlv19161_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16df6b90-d049-4160-b148-b888e03acb82"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8faaf976-ea71-4910-9243-aee1cb5d3875"}}}}, {"uuid": "ba2ff638-568b-4237-b84f-6b8c4a91bc05", "name": "4cccfcec-862f-4664-bc65-7422e770750e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7930e8d4-bccc-4cf3-ae0f-3a50b581908a", "name": "b97340dc-d707-4767-8f8a-4206a3059695", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ba2ff638-568b-4237-b84f-6b8c4a91bc05"}}}]}, {"uuid": "4dfa51cb-050b-4616-880a-0ee67149a094", "name": "load_p1rlv19163_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fed6fcd4-3c97-4f62-a1a7-0b66394218e1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7930e8d4-bccc-4cf3-ae0f-3a50b581908a"}}}}, {"uuid": "b8d6d56e-9c72-4836-a2df-3cfa8013d452", "name": "7c3bf019-abfc-4bf4-8cf1-e4ee76528b6e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "78416a8d-5298-4100-90be-2e4fbc91d751", "name": "113e1321-cf95-47fb-9d92-56087fa014ad", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b8d6d56e-9c72-4836-a2df-3cfa8013d452"}}}]}, {"uuid": "f3f19601-292b-41de-af2e-8f3b1c6b0ae1", "name": "load_p1rlv19163_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fed6fcd4-3c97-4f62-a1a7-0b66394218e1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "78416a8d-5298-4100-90be-2e4fbc91d751"}}}}, {"uuid": "26aaa96b-786e-465c-a2d1-c8894affa276", "name": "de992046-31fd-456e-98b2-a83d9c206b75_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3913635530264314, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9282144314028667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aba50749-2a23-4445-9c0c-330d4aa4cf87", "name": "de992046-31fd-456e-98b2-a83d9c206b75_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3913635530264314, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9282144314028667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "717e806b-fad7-4a1d-916d-8b9115a4d843", "name": "de992046-31fd-456e-98b2-a83d9c206b75_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3913635530264314, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9282144314028667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b979ccd5-2f40-4746-a988-7df3e6b51ee6", "name": "c19c01a7-bb70-4fbf-a2ef-a87e599a4cc5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "26aaa96b-786e-465c-a2d1-c8894affa276"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aba50749-2a23-4445-9c0c-330d4aa4cf87"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "717e806b-fad7-4a1d-916d-8b9115a4d843"}}}]}, {"uuid": "3d93ef47-7f16-49ac-9061-3becf93bfb2e", "name": "load_p1rlv19164", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a02024b5-aa74-4e07-b043-a7a0e8b3e816"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b979ccd5-2f40-4746-a988-7df3e6b51ee6"}}}}, {"uuid": "44176e23-55fa-417c-9129-d715bc9d37e0", "name": "59d63d88-9fc3-472f-8ae1-7306b898b5b5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ff428f8c-2c3a-46ad-bb5b-4f6b3daa897a", "name": "793c4ce9-ef93-447c-969f-d8e370b4e3dc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "44176e23-55fa-417c-9129-d715bc9d37e0"}}}]}, {"uuid": "c19138fe-01ee-49cb-a8d6-b4871fe9a83d", "name": "load_p1rlv19165_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ebd10471-ab4c-4cb7-a822-a83ef20e9854"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ff428f8c-2c3a-46ad-bb5b-4f6b3daa897a"}}}}, {"uuid": "bd2d7e35-1845-408c-b298-02efde1b9cc8", "name": "30aadc1d-05e6-4d31-8f9e-392ba2a57f56_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5c200c50-9ade-4276-ac85-c37b94497797", "name": "4fe8aa86-072e-40d4-8c13-0a754e43967c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bd2d7e35-1845-408c-b298-02efde1b9cc8"}}}]}, {"uuid": "40f5f2ab-ba0c-40cb-bebf-3a82bfd0403b", "name": "load_p1rlv19165_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ebd10471-ab4c-4cb7-a822-a83ef20e9854"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5c200c50-9ade-4276-ac85-c37b94497797"}}}}, {"uuid": "db3a33cb-eb5f-4d19-8040-6ec5f2a248af", "name": "a0625715-56f8-4fdf-b453-3d7c15955b12_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c91b903a-179b-4b9c-8a91-ca04a45d4c0e", "name": "81bc24f8-de82-433f-8707-28c12fd0084a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "db3a33cb-eb5f-4d19-8040-6ec5f2a248af"}}}]}, {"uuid": "39bbf73a-53c6-4b2b-913c-1c0af0433c80", "name": "load_p1rlv19166_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "994f6392-f4e5-4ff8-9eeb-5849cd035912"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c91b903a-179b-4b9c-8a91-ca04a45d4c0e"}}}}, {"uuid": "8d2ed1ec-5a98-4037-90f6-92b438806eed", "name": "1094c4fe-7f5e-4bc1-a61c-0c9559c421da_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f285ff05-ecb6-4188-8db3-8a067e42b5ee", "name": "18649bc0-1baa-4dee-ab9d-f81face75a14", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8d2ed1ec-5a98-4037-90f6-92b438806eed"}}}]}, {"uuid": "07192b48-5d44-4d05-a633-d35c26bff647", "name": "load_p1rlv19166_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "994f6392-f4e5-4ff8-9eeb-5849cd035912"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f285ff05-ecb6-4188-8db3-8a067e42b5ee"}}}}, {"uuid": "51a86754-b9fd-4736-924c-c05f7f8f24cf", "name": "e0397dfc-2399-4620-a56c-99c8d416d2bc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6733980323267108, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22626974414284334, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50c4c48d-222e-4c54-8b4a-f763bdd5b7ce", "name": "44939ef2-1366-47f1-8979-9355dc7e84ee", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "51a86754-b9fd-4736-924c-c05f7f8f24cf"}}}]}, {"uuid": "e04e6f75-8d46-4726-bc92-bc890f422c32", "name": "load_p1rlv19168_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f8c76ca-40ea-4f7d-8042-66edd484f065"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50c4c48d-222e-4c54-8b4a-f763bdd5b7ce"}}}}, {"uuid": "f3bb7e45-84ac-4e2e-8c6c-125d4bcc1ede", "name": "a8ea18d3-c0a0-4561-80db-be47d3e3b27a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6733980323267108, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22626974414284334, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4e293a52-1321-43e4-986f-ff0fca24cd10", "name": "ebfa6fc3-90e8-4825-b481-5a41ede38177", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f3bb7e45-84ac-4e2e-8c6c-125d4bcc1ede"}}}]}, {"uuid": "29924464-4e3b-4d6c-9dcd-7a76c3a12c3c", "name": "load_p1rlv19168_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f8c76ca-40ea-4f7d-8042-66edd484f065"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4e293a52-1321-43e4-986f-ff0fca24cd10"}}}}, {"uuid": "96ad5f29-86ea-420a-a9cd-cbe7ca2e48eb", "name": "7db4b8c9-b98e-45ba-8a81-e9ce5bd4bb30_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0288569450045768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2608148575838028, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "23503b5a-e59b-4bb1-99f8-1e372e32a039", "name": "62c2d498-c75f-447d-8219-db50186f09b6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "96ad5f29-86ea-420a-a9cd-cbe7ca2e48eb"}}}]}, {"uuid": "e7dff548-5064-438a-a413-9aff670679b5", "name": "load_p1rlv19169_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4e8183-9148-477e-aa1b-ff31a5324273"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "23503b5a-e59b-4bb1-99f8-1e372e32a039"}}}}, {"uuid": "7386bf6b-5ea9-40f9-81d4-65cc62638403", "name": "4b60ec54-5e0c-4c8f-b177-4f0bffa4eab6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0288569450045768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2608148575838028, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b3b308a3-95f6-4303-ba39-ab01f40fb440", "name": "0a6d326f-8727-46a0-ac05-12991b041c50", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7386bf6b-5ea9-40f9-81d4-65cc62638403"}}}]}, {"uuid": "95cd4e39-549f-4256-bf1b-88f6a43ef741", "name": "load_p1rlv19169_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4e8183-9148-477e-aa1b-ff31a5324273"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b3b308a3-95f6-4303-ba39-ab01f40fb440"}}}}, {"uuid": "3e51eee4-c9b9-48b9-a509-6f5d3e28c164", "name": "ccaac138-77af-4e48-916d-b215032ae845_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9179777962446224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3481400399277513, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f5d6c979-9438-4c19-8522-4d45c399fcb9", "name": "88fa76d0-d740-4eb3-8795-a964b43c92f7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3e51eee4-c9b9-48b9-a509-6f5d3e28c164"}}}]}, {"uuid": "3f6ce2c3-d243-479a-a3f8-620a114cebfe", "name": "load_p1rlv19171_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fffe26f7-c4cc-420e-ab17-754cb0d9e659"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f5d6c979-9438-4c19-8522-4d45c399fcb9"}}}}, {"uuid": "d6c1250f-f71d-4f1a-bb72-14dfd31baa8a", "name": "16f46533-7fb7-48d6-a498-b14c5792acee_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9179777962446224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3481400399277513, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6a2bd906-7f88-4096-9f94-b57562a4e999", "name": "1226bbba-e446-4d18-ba7f-61609911329c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d6c1250f-f71d-4f1a-bb72-14dfd31baa8a"}}}]}, {"uuid": "5b046daf-851a-4c1b-bf0d-1ec757448c4d", "name": "load_p1rlv19171_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fffe26f7-c4cc-420e-ab17-754cb0d9e659"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6a2bd906-7f88-4096-9f94-b57562a4e999"}}}}, {"uuid": "f5c47ead-457b-4112-ad8c-4800362713a6", "name": "f3fed72c-794e-4ccf-bc98-1ddfbcffbf3e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2767849318619047, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.48605417385422345, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f0954b2-7595-4880-a85c-16379689a5a3", "name": "1f0ab7cf-00b3-4787-82dd-921330051fe0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f5c47ead-457b-4112-ad8c-4800362713a6"}}}]}, {"uuid": "de37a26e-d354-4d16-9ee2-102d49f9e97c", "name": "load_p1rlv19173_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21fec301-b67c-4042-a074-caf406c7f0b5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f0954b2-7595-4880-a85c-16379689a5a3"}}}}, {"uuid": "2755ca43-8485-4ee8-9f11-17dfc565e8b4", "name": "bf502988-57ea-4c56-817e-faeb9c732a97_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2767849318619047, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.48605417385422345, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "56afcfe9-dd5a-47a8-a53d-ba1dbef8cef0", "name": "c11a0f4c-9a5b-42bf-815d-2910e39bb476", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2755ca43-8485-4ee8-9f11-17dfc565e8b4"}}}]}, {"uuid": "fa66facc-d041-44f5-865d-955b3f553535", "name": "load_p1rlv19173_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21fec301-b67c-4042-a074-caf406c7f0b5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "56afcfe9-dd5a-47a8-a53d-ba1dbef8cef0"}}}}, {"uuid": "a8ae73b7-6e03-45d9-88de-409827be9cba", "name": "c2bd9970-2177-4852-a67c-9100fdfe36c5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4675207102133878, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42773122049615037, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b13a61e3-6de6-4b4d-ac19-c5e0a0b750b2", "name": "a98c29a4-7501-485a-9244-e39748d5e127", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a8ae73b7-6e03-45d9-88de-409827be9cba"}}}]}, {"uuid": "a0c7ea11-2c63-436f-879b-8ec104b8b6af", "name": "load_p1rlv19174_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0fc7d43-4f82-4100-99bf-6e30e03e95ce"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b13a61e3-6de6-4b4d-ac19-c5e0a0b750b2"}}}}, {"uuid": "fce4b9b9-ef25-43db-b488-7c2ccd0c63ed", "name": "827cf8ba-b9b6-4746-bab5-e2cecc2e9125_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4675207102133878, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42773122049615037, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7a4cae4e-d607-441d-8748-6f41ba771bd7", "name": "7fb7b1de-b694-4253-aed5-7dfb0b2b674f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fce4b9b9-ef25-43db-b488-7c2ccd0c63ed"}}}]}, {"uuid": "f84efad9-2336-4892-ac50-8af41feac531", "name": "load_p1rlv19174_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0fc7d43-4f82-4100-99bf-6e30e03e95ce"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7a4cae4e-d607-441d-8748-6f41ba771bd7"}}}}, {"uuid": "e654623f-313c-4b11-9315-ba6f2ef0b77e", "name": "dc4c20ae-4a63-412e-810d-23b4fd6c1190_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4660310317378347, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6643122913958558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "04555b76-290e-4556-b6b5-aa452336de03", "name": "c47057d9-5386-48fb-b604-4f93f2f5d2e1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e654623f-313c-4b11-9315-ba6f2ef0b77e"}}}]}, {"uuid": "061d6c99-a938-4855-b40a-9ef3068c8ecb", "name": "load_p1rlv19183_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "89bde057-807b-415c-9135-267c6bf43c44"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "04555b76-290e-4556-b6b5-aa452336de03"}}}}, {"uuid": "d0c2da70-16d4-4628-b508-621ecdfeeed0", "name": "c4771986-d8bf-440d-9b02-89deba7df031_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4660310317378347, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6643122913958558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6df221e1-7eb3-418c-ae30-18231f96db2c", "name": "4d7441d4-a0b8-4f87-a28f-9cc6381503b8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d0c2da70-16d4-4628-b508-621ecdfeeed0"}}}]}, {"uuid": "8ac36c2a-9eb2-4707-94ab-d7fed5c8d220", "name": "load_p1rlv19183_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "89bde057-807b-415c-9135-267c6bf43c44"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6df221e1-7eb3-418c-ae30-18231f96db2c"}}}}, {"uuid": "b079212d-2bdf-4bca-ae52-116cbe4167c7", "name": "860c4415-3bb1-4dc0-8a44-3322d4fe5bf7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.515259426400046, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4440975656599118, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3d8f19ec-f5a5-40d6-a2dd-707046dd3177", "name": "3c640dd5-a945-4231-8a4f-1bff34e77eb3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b079212d-2bdf-4bca-ae52-116cbe4167c7"}}}]}, {"uuid": "b6de3fac-4d6b-4a52-a9e2-e974cac85e5d", "name": "load_p1rlv19184_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50750ddb-80db-4d5f-bc62-4bbfc600a7ef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3d8f19ec-f5a5-40d6-a2dd-707046dd3177"}}}}, {"uuid": "75f6a9a4-4da0-4ec3-84b7-005556956265", "name": "89105886-e868-4927-8559-64821a385e04_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.515259426400046, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4440975656599118, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "efc0f742-5b1f-43a0-b2d4-5573c1a4d140", "name": "6e84dfc1-a870-431a-a07e-760ec8df0377", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "75f6a9a4-4da0-4ec3-84b7-005556956265"}}}]}, {"uuid": "971cc166-3ac8-4edc-b2a2-3530ffcaff58", "name": "load_p1rlv19184_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50750ddb-80db-4d5f-bc62-4bbfc600a7ef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "efc0f742-5b1f-43a0-b2d4-5573c1a4d140"}}}}, {"uuid": "754642c3-e803-4f34-baff-f09e25515573", "name": "baa45f2f-c3a6-49db-858a-ebdf21e7d73f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4040789998842194, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4565305929598704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5a7516eb-2e14-471b-b1a5-80ff03ee3fa7", "name": "d751e070-701e-4082-850e-878f679e40fa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "754642c3-e803-4f34-baff-f09e25515573"}}}]}, {"uuid": "66f572e4-3523-4380-9a62-0e30fd1a5db1", "name": "load_p1rlv19188_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47e24942-486d-46f1-a40f-0da5c93c013a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5a7516eb-2e14-471b-b1a5-80ff03ee3fa7"}}}}, {"uuid": "dad37bec-9b09-4868-9885-d2bcb994668d", "name": "32b1c83a-d83e-49c3-a245-2eeb2851a00a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4040789998842194, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4565305929598704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8014c6ba-e17d-4245-a9f8-48da6e5f0bd4", "name": "c16b5c3a-cb3c-48ec-80a5-95cc90f22f7b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dad37bec-9b09-4868-9885-d2bcb994668d"}}}]}, {"uuid": "e438f8bd-9345-4a19-a5dd-8239ac819ea3", "name": "load_p1rlv19188_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47e24942-486d-46f1-a40f-0da5c93c013a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8014c6ba-e17d-4245-a9f8-48da6e5f0bd4"}}}}, {"uuid": "7a9d7dc7-316b-40fa-b29f-90498d17c758", "name": "26b13717-8147-43cd-b52a-6d4b427ecf93_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.600795001494098, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2809795860066686, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eecd4421-78a7-416b-a3a3-deaf14e94d32", "name": "8205e059-91bc-4214-a0aa-c7c79f3147f7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7a9d7dc7-316b-40fa-b29f-90498d17c758"}}}]}, {"uuid": "1098ee10-5a4e-4a3c-b15d-d74068a9626a", "name": "load_p1rlv19189_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5fecc64a-4783-4ecb-a0d0-7e60d1cf6184"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eecd4421-78a7-416b-a3a3-deaf14e94d32"}}}}, {"uuid": "b052e304-473c-4eb4-860a-9a0bc656d98c", "name": "5d5bbf5b-4aec-4c9d-8284-8b9c4382b100_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.600795001494098, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2809795860066686, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7b3d9326-cef3-4965-890b-b628e4d53fec", "name": "754cf4af-6527-48c8-95e7-26b2c749a595", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b052e304-473c-4eb4-860a-9a0bc656d98c"}}}]}, {"uuid": "7473f293-ed7f-4335-bafc-5a15171814ac", "name": "load_p1rlv19189_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5fecc64a-4783-4ecb-a0d0-7e60d1cf6184"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7b3d9326-cef3-4965-890b-b628e4d53fec"}}}}, {"uuid": "00b124f3-cc84-430f-97a4-73423875313a", "name": "ceee5312-17ae-4fbf-b3d8-9867944bd18c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0490448796184286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8093782533373945, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "afbf58b1-8dca-4241-b36b-51ca85dc011d", "name": "2a4fd228-46cf-41a5-9624-030a18ec5c56", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "00b124f3-cc84-430f-97a4-73423875313a"}}}]}, {"uuid": "7a57a2de-df82-4671-9dcd-3f69ee3acdfb", "name": "load_p1rlv19190_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4aee02d4-8663-455b-a197-55b6b1470895"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "afbf58b1-8dca-4241-b36b-51ca85dc011d"}}}}, {"uuid": "04f380b5-c1ee-4699-8ded-bef9e45c57bb", "name": "857dc4d5-e612-450a-a93b-fa84a87f8f28_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0490448796184286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8093782533373945, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "006b69f8-f94f-41c8-87f5-22b2ee2e8765", "name": "d9ddc10a-cf53-4859-9d95-35c61f4addc0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "04f380b5-c1ee-4699-8ded-bef9e45c57bb"}}}]}, {"uuid": "7f756e00-95e8-4749-99b7-6533fb0bc45e", "name": "load_p1rlv19190_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4aee02d4-8663-455b-a197-55b6b1470895"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "006b69f8-f94f-41c8-87f5-22b2ee2e8765"}}}}, {"uuid": "7ed29888-5e04-490f-aa78-e62dd67093f3", "name": "a040e458-a970-4c7d-9686-89d2fcbe69ff_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7073298240395912, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.27247283022117846, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a0042c48-29f7-4122-9d41-8e1b226a1fa2", "name": "684f1f72-1aed-481a-bd57-43848c78bb39", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7ed29888-5e04-490f-aa78-e62dd67093f3"}}}]}, {"uuid": "5a6858d9-dc19-4959-bfe2-02bb18b2bb2f", "name": "load_p1rlv19194_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7daa1d3-6249-447d-a260-65de5ec0a470"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a0042c48-29f7-4122-9d41-8e1b226a1fa2"}}}}, {"uuid": "f3072aaf-be87-40e4-84fc-c06c6ea3506e", "name": "a7671389-ac45-4876-be86-4ad168ed35a0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7073298240395912, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.27247283022117846, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ed4e9771-7f88-46a3-a65f-5a9bd2944670", "name": "14dcf3fc-3c25-4d56-801f-913d72d024fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f3072aaf-be87-40e4-84fc-c06c6ea3506e"}}}]}, {"uuid": "bfd4db25-0215-426a-b567-04a4ac298abd", "name": "load_p1rlv19194_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7daa1d3-6249-447d-a260-65de5ec0a470"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ed4e9771-7f88-46a3-a65f-5a9bd2944670"}}}}, {"uuid": "3e86aca5-6aab-4f92-ae50-2bddbb36e1be", "name": "af904d00-c1d6-47a9-8edc-0af7c25654b2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5757409771642927, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7652901499575055, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d9809f00-acc3-4d7e-9b89-1477725e87a3", "name": "e0954155-7e81-40da-9db5-b2d1b498ce7a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3e86aca5-6aab-4f92-ae50-2bddbb36e1be"}}}]}, {"uuid": "eac7a319-9e7b-4f16-ad17-ce684bc7550d", "name": "load_p1rlv19667_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33dcb037-4cc8-480f-aac4-bc95e54e165e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d9809f00-acc3-4d7e-9b89-1477725e87a3"}}}}, {"uuid": "ccde68f5-b039-4bda-ae4c-9efd64edbf23", "name": "b40bf064-50a2-4e66-a1e0-0d7e208df0bc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5757409771642927, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7652901499575055, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d5d225fe-1f02-44a7-9290-99e5d55a6faa", "name": "c8517da0-0aae-4d9e-80d3-b8b25f936384", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ccde68f5-b039-4bda-ae4c-9efd64edbf23"}}}]}, {"uuid": "159a267b-a341-462f-af3b-8d2fa2d7a9d3", "name": "load_p1rlv19667_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33dcb037-4cc8-480f-aac4-bc95e54e165e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d5d225fe-1f02-44a7-9290-99e5d55a6faa"}}}}, {"uuid": "ea589c8f-cc85-4486-a172-dcfb51a011cf", "name": "6ff93963-157c-49bf-808e-721b4befa146_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.539100612527363, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.549143952601146, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ae4c2fae-3337-426c-b97e-93002c961cff", "name": "f70c2f5e-b770-488a-ac4d-23d574d34886", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ea589c8f-cc85-4486-a172-dcfb51a011cf"}}}]}, {"uuid": "dd60ac8b-a84d-40ba-9706-2eefe88e3183", "name": "load_p1rlv19668_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6427f66-2e22-40bb-83f1-2a8b1be9191a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ae4c2fae-3337-426c-b97e-93002c961cff"}}}}, {"uuid": "ef8495a0-4d6b-4995-9400-667c6fe969bb", "name": "9f15c2b1-07cb-41d4-84c2-b17acd8dffbf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.539100612527363, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.549143952601146, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c6c85d9c-f0c9-47a9-9a63-ed573637a24e", "name": "c979cb7e-77c5-47f1-b96d-fba1ec56a04b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ef8495a0-4d6b-4995-9400-667c6fe969bb"}}}]}, {"uuid": "4e059a4d-2a38-4306-845c-491ec42a2875", "name": "load_p1rlv19668_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6427f66-2e22-40bb-83f1-2a8b1be9191a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c6c85d9c-f0c9-47a9-9a63-ed573637a24e"}}}}, {"uuid": "f27f007c-2e11-4bdb-bb7e-100621d0bc49", "name": "44437314-92d0-4a62-9834-4fb8eaae5d2e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4037437915385973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5086059213404144, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b949ff1c-0f56-4d40-a461-22cc4cdac93d", "name": "8bae368a-487c-4de4-831a-d8fc546f342b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f27f007c-2e11-4bdb-bb7e-100621d0bc49"}}}]}, {"uuid": "8a5023e4-c0f5-44a0-a855-3398bd2dc9c9", "name": "load_p1rlv19669_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96d3079a-02f1-4c89-ad75-fd0a438c9cf4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b949ff1c-0f56-4d40-a461-22cc4cdac93d"}}}}, {"uuid": "d33f15fc-edf5-4bfa-a3d5-74552ed68265", "name": "61b541aa-9206-4840-ac4f-706ef534c1f5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4037437915385973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5086059213404144, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "117008e9-c0bf-4cc9-b860-289a2d757b15", "name": "8a0f45ea-92a7-4798-8d8f-ebe97c55be71", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d33f15fc-edf5-4bfa-a3d5-74552ed68265"}}}]}, {"uuid": "a21aa7c8-8062-4e99-a92d-1883e14314dc", "name": "load_p1rlv19669_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96d3079a-02f1-4c89-ad75-fd0a438c9cf4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "117008e9-c0bf-4cc9-b860-289a2d757b15"}}}}, {"uuid": "2603ec16-0540-4eeb-a2cd-701568cc54c0", "name": "179e0570-a4a0-4b27-babd-3f4c9ccc0700_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.308477864741614, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307751830484037, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bb9e05e9-b83a-4c56-868c-c22d46686968", "name": "ccb173c5-314b-446f-99a3-56f5a6f88a2e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2603ec16-0540-4eeb-a2cd-701568cc54c0"}}}]}, {"uuid": "10d06a86-24d8-43c3-be81-9e7524c167b8", "name": "load_p1rlv19675_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0031ab1b-d82d-40a5-b41e-bc6f6cb53069"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bb9e05e9-b83a-4c56-868c-c22d46686968"}}}}, {"uuid": "19e75e2a-07c5-4b8d-9791-c5f455991a2b", "name": "eeea6a3d-a27e-466c-b070-2ecd8d446e1f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.308477864741614, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307751830484037, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d7ca90cb-332d-4801-bedc-06caa0a9d9b9", "name": "69c8d922-d412-4b91-aa6a-1c77f7b1828a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "19e75e2a-07c5-4b8d-9791-c5f455991a2b"}}}]}, {"uuid": "d2997514-1651-4b24-9fbe-70e223296d34", "name": "load_p1rlv19675_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0031ab1b-d82d-40a5-b41e-bc6f6cb53069"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d7ca90cb-332d-4801-bedc-06caa0a9d9b9"}}}}, {"uuid": "3a9b348e-e778-4211-801f-9e6f1d945b9c", "name": "9930f8d0-e7ac-478b-a9f3-6b79645baaaa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4359784649582454, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.14838741475370543, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f5ab5822-1abe-4c20-b73a-0de7d7ba03a1", "name": "ef801244-6147-4689-a91b-878c0eaf26d9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3a9b348e-e778-4211-801f-9e6f1d945b9c"}}}]}, {"uuid": "ad50bdea-72ac-428a-acdf-166a01d5d7af", "name": "load_p1rlv19681_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83afc678-d577-4ef1-afa2-8e3f915a158b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f5ab5822-1abe-4c20-b73a-0de7d7ba03a1"}}}}, {"uuid": "59538ed4-fede-470a-822f-3b8d98eb3227", "name": "29f77274-9da6-4ea5-a124-b6f948542cf6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4359784649582454, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.14838741475370543, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0338d20b-ad9a-42c7-8b29-7ed52185693a", "name": "4a81538b-7048-42c6-b044-9669b84e90c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "59538ed4-fede-470a-822f-3b8d98eb3227"}}}]}, {"uuid": "b3a4b610-473d-4d59-9f38-1d36ac630f13", "name": "load_p1rlv19681_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83afc678-d577-4ef1-afa2-8e3f915a158b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0338d20b-ad9a-42c7-8b29-7ed52185693a"}}}}, {"uuid": "d1d0c3a6-4a7f-400b-a363-43c849f9c524", "name": "66047564-508a-4cec-b8ce-63f7ef123416_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4849313480010438, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7277224910757479, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "77941e17-d559-4b1f-b3a3-600923300a63", "name": "3935ff4f-cb25-4218-b2e7-8cd01e2a9328", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d1d0c3a6-4a7f-400b-a363-43c849f9c524"}}}]}, {"uuid": "10735e5a-5755-40a0-8e82-1d583800ddcd", "name": "load_p1rlv19682_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "811acd48-b61c-4a42-b76e-f995961c450e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "77941e17-d559-4b1f-b3a3-600923300a63"}}}}, {"uuid": "fe7d7d58-2846-4202-8450-e78c57fe55f0", "name": "67b3f1c5-2afe-4529-a0f5-ef4b9c245518_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4849313480010438, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7277224910757479, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "42a267db-803a-4bc8-a40d-d8ab8ee7b199", "name": "7fc602c6-9be3-4295-b436-83f2fc0ea5e2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fe7d7d58-2846-4202-8450-e78c57fe55f0"}}}]}, {"uuid": "53946547-2e1c-4c77-a55f-c649d926f97d", "name": "load_p1rlv19682_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "811acd48-b61c-4a42-b76e-f995961c450e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "42a267db-803a-4bc8-a40d-d8ab8ee7b199"}}}}, {"uuid": "d26bc30f-0158-4c51-917f-c60ce491b3fb", "name": "b8d0cf34-a770-4338-910b-adc97ba3d421_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2440101223346245, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10648703060010346, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1acdbbdd-5dcb-4b9e-9a4e-5bc71457e53d", "name": "a127345d-9a3b-48db-bf79-acbad49eb2aa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d26bc30f-0158-4c51-917f-c60ce491b3fb"}}}]}, {"uuid": "1ed25cf3-552c-44cd-b511-1701113ba3c8", "name": "load_p1rlv19686_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47f5777d-2c8d-48c2-bf28-386f3f3dbac4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1acdbbdd-5dcb-4b9e-9a4e-5bc71457e53d"}}}}, {"uuid": "af93eee8-f9bb-442b-a583-01f70afd4be2", "name": "6d593d1f-33a6-427a-b162-895b1023099a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2440101223346245, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10648703060010346, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "65e22d17-96fc-4665-886e-7e790749b309", "name": "303f0c22-2214-43e0-8822-e0bf37a2d074", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "af93eee8-f9bb-442b-a583-01f70afd4be2"}}}]}, {"uuid": "edfb7a27-0781-491e-8b2c-05146ed035ea", "name": "load_p1rlv19686_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47f5777d-2c8d-48c2-bf28-386f3f3dbac4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "65e22d17-96fc-4665-886e-7e790749b309"}}}}, {"uuid": "8a3bd121-0a2f-44af-8082-f24496c7efe4", "name": "048758ca-e638-4bfd-8d21-93557dbc8592_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.895690985965537, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9400572249599172, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "80125096-6207-409a-b0d9-669647c2319a", "name": "08ab45e8-b3a6-4390-a198-d173f57dec21", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a3bd121-0a2f-44af-8082-f24496c7efe4"}}}]}, {"uuid": "5305c7c6-d109-4a09-b2a2-f92de08df8bd", "name": "load_p1rlv19689_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "578b5df8-1dd8-41d9-b6dc-db75db5b115e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "80125096-6207-409a-b0d9-669647c2319a"}}}}, {"uuid": "69ac157c-6e9f-4962-b7cd-69c3655c9828", "name": "bc38a9b4-53f4-432b-a1d0-61ccee37928b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.895690985965537, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9400572249599172, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "43567337-5bcb-4f0c-8318-114fb73d774a", "name": "b7bfa72b-5be3-4ee8-98c8-62cfb2e5ba89", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "69ac157c-6e9f-4962-b7cd-69c3655c9828"}}}]}, {"uuid": "54029791-40d2-46d2-b363-b156e77814c3", "name": "load_p1rlv19689_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "578b5df8-1dd8-41d9-b6dc-db75db5b115e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "43567337-5bcb-4f0c-8318-114fb73d774a"}}}}, {"uuid": "c165eb8f-b5a6-4e6d-9104-35e132a992cc", "name": "c3532b3a-9e3e-417c-9ee3-307cd4b961fd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.308477864741614, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307751830484037, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1b649937-0e7f-494f-b253-419d69e74bab", "name": "76d649ac-cd9e-4f5c-8296-c2ba742698b1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c165eb8f-b5a6-4e6d-9104-35e132a992cc"}}}]}, {"uuid": "c66fa230-0cb1-48ff-ae1e-b329cd193928", "name": "load_p1rlv19690_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2709a70-1a7d-454c-90fd-377e416a0071"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1b649937-0e7f-494f-b253-419d69e74bab"}}}}, {"uuid": "4e74008a-5710-4b3a-b8df-8f73b24776d4", "name": "0347b171-ddc6-480b-8f2e-881491975645_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.308477864741614, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307751830484037, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8b8100cd-4d06-4016-874c-663fb29a2a84", "name": "e0c941a5-31a2-43c6-8d2c-7bab3fe96d52", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4e74008a-5710-4b3a-b8df-8f73b24776d4"}}}]}, {"uuid": "f5b02566-069f-4c58-a0a6-5eed94d9e47c", "name": "load_p1rlv19690_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2709a70-1a7d-454c-90fd-377e416a0071"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8b8100cd-4d06-4016-874c-663fb29a2a84"}}}}, {"uuid": "77165c56-c89d-4ebb-ad57-9b1e28126383", "name": "48fa7aea-32e0-4c8a-bbd1-1cebf6f5d9b6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5901541038441702, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.07457634724192848, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fc34bb05-87f4-4799-a01d-3927f582bcd6", "name": "34f24218-15e1-4f5c-9d09-301a0c1f76cb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "77165c56-c89d-4ebb-ad57-9b1e28126383"}}}]}, {"uuid": "9b820f03-083c-4edf-81ea-27dfe2aee5e5", "name": "load_p1rlv19691_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "604cb559-0f18-4ef7-8bcd-a07a7e7f96d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fc34bb05-87f4-4799-a01d-3927f582bcd6"}}}}, {"uuid": "3a4a5f53-1e04-402a-a6db-3045fa896c82", "name": "788da8c3-0c69-4a0a-8924-972af172aebf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5901541038441702, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.07457634724192848, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "58a9b220-c202-49b7-be70-961245a29423", "name": "05b00e44-bc66-4e6e-a026-9cdc0e5901ac", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3a4a5f53-1e04-402a-a6db-3045fa896c82"}}}]}, {"uuid": "88111d81-0056-4c62-8fa1-ad8367b8b2d7", "name": "load_p1rlv19691_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "604cb559-0f18-4ef7-8bcd-a07a7e7f96d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "58a9b220-c202-49b7-be70-961245a29423"}}}}, {"uuid": "cf87f2b7-175d-4ce8-84c5-e47d6819cd32", "name": "f611a5d7-dea6-405a-9320-609bc39ca2c3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.424079283052672, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.088828085193726, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "28d0d815-3de0-490c-94ae-4c4fa92969da", "name": "f40f87e8-d79c-4aea-a77f-fe8f67002d74", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cf87f2b7-175d-4ce8-84c5-e47d6819cd32"}}}]}, {"uuid": "620421db-9084-49f1-afa1-15b5180d2e9d", "name": "load_p1rlv19692_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b10b272a-2efb-4e19-9921-d4081fb45778"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "28d0d815-3de0-490c-94ae-4c4fa92969da"}}}}, {"uuid": "6201eba7-27e1-4bfa-9236-6be455ae382f", "name": "874ea8ba-2e4a-4758-8910-ffb5aba63a6d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.424079283052672, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.088828085193726, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8fc451d1-1b3a-4027-b6e4-5ab4e353ac33", "name": "c428ca70-9ec6-42e4-9498-df2ce9a9ac01", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6201eba7-27e1-4bfa-9236-6be455ae382f"}}}]}, {"uuid": "89953e12-96e9-494d-a5bc-45969cf03417", "name": "load_p1rlv19692_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b10b272a-2efb-4e19-9921-d4081fb45778"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8fc451d1-1b3a-4027-b6e4-5ab4e353ac33"}}}}, {"uuid": "3e120d1d-e367-4433-8b5c-5cfa4c05bfc7", "name": "c623f11b-f702-4be1-b6b2-d417ae367f0e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.01164824929789, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.30321095330991316, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8e3290d6-521b-4a69-9aa7-a5478a53a9a7", "name": "54f4d3c8-6a3a-4744-a32c-5dacea40d4b8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3e120d1d-e367-4433-8b5c-5cfa4c05bfc7"}}}]}, {"uuid": "98a8d7ce-fa0d-4b53-b172-4c1b6aba6bf7", "name": "load_p1rlv19695_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35fe21a1-f817-426e-9e42-f1f33876dd7d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8e3290d6-521b-4a69-9aa7-a5478a53a9a7"}}}}, {"uuid": "eec4bf16-f1ed-4404-8554-8574940fe947", "name": "272ae202-08fa-4d80-839a-9a3080a1e95f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.01164824929789, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.30321095330991316, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7f95e30e-ea29-451d-87fb-c069d649283a", "name": "6493fce6-8465-4769-9eee-2221707dc58f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eec4bf16-f1ed-4404-8554-8574940fe947"}}}]}, {"uuid": "c20c99cb-c78e-4ae5-aa2e-2accbced38cf", "name": "load_p1rlv19695_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35fe21a1-f817-426e-9e42-f1f33876dd7d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7f95e30e-ea29-451d-87fb-c069d649283a"}}}}, {"uuid": "f145327e-2162-42b6-8a11-26b2bfde7600", "name": "a9857ff6-34b2-4ec8-843b-b4f93dab0a28_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.445994317964332, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8597073331859654, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0c3432cf-d00e-420c-ad29-b45eceacc58a", "name": "632e3014-86c5-401b-9e6a-ea8235b3a564", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f145327e-2162-42b6-8a11-26b2bfde7600"}}}]}, {"uuid": "e7c985a2-dd3e-4ea6-a120-8c6d8e866d63", "name": "load_p1rlv19698_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14b1ab4e-b22d-4a98-8131-fc72c923c735"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0c3432cf-d00e-420c-ad29-b45eceacc58a"}}}}, {"uuid": "b8c806b8-d2d3-4b6e-9b57-3cb8b968f85c", "name": "d51b1bd3-7852-492c-a51e-5ca1e90b38b4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.445994317964332, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8597073331859654, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6354f900-88a1-49f8-bd70-306ee4e16e14", "name": "0a0e1126-55ca-455d-8658-67827e307025", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b8c806b8-d2d3-4b6e-9b57-3cb8b968f85c"}}}]}, {"uuid": "a9fe8784-2888-44a7-afa3-24d828418cda", "name": "load_p1rlv19698_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14b1ab4e-b22d-4a98-8131-fc72c923c735"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6354f900-88a1-49f8-bd70-306ee4e16e14"}}}}, {"uuid": "f317c62a-0a34-4e0b-bffb-508a05b0080c", "name": "162071be-39d3-423a-9165-bfd64e018cd2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4663769608466568, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5502546109327153, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fc82c7e2-b64e-46ce-ac11-0609a93d3242", "name": "ca1e6878-747f-48b5-aafb-2e7baf793657", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f317c62a-0a34-4e0b-bffb-508a05b0080c"}}}]}, {"uuid": "888dbe4f-cd30-4381-bcec-a643f2c74829", "name": "load_p1rlv19699_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48654a82-ac11-4542-94ec-8f731138e1a8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fc82c7e2-b64e-46ce-ac11-0609a93d3242"}}}}, {"uuid": "462bcf4f-c7e0-42f4-b852-f1a30a0b2a49", "name": "678cde70-2782-44ef-94fa-676fc2adb482_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4663769608466568, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5502546109327153, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cf65c499-b81c-4756-b5fc-cb82c815f025", "name": "f57da8ee-9669-44e5-b79d-404a52a01290", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "462bcf4f-c7e0-42f4-b852-f1a30a0b2a49"}}}]}, {"uuid": "fbe73a3c-692a-4ac9-851d-923425420048", "name": "load_p1rlv19699_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48654a82-ac11-4542-94ec-8f731138e1a8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cf65c499-b81c-4756-b5fc-cb82c815f025"}}}}, {"uuid": "179a4141-de77-4c08-a44c-94bc38111e71", "name": "b8edef17-753c-4640-ac88-234b59bd56b6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.331677082668279, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10958157805626084, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "de6c7d43-35c0-417e-9fbd-95f4c1c8135d", "name": "757edf94-1466-40b6-96a7-ca913b133456", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "179a4141-de77-4c08-a44c-94bc38111e71"}}}]}, {"uuid": "4e5e96cb-f1a5-43fa-93cb-23867576491d", "name": "load_p1rlv19701_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b5d936f-b3e0-408e-aabd-d3ebb7b869b0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "de6c7d43-35c0-417e-9fbd-95f4c1c8135d"}}}}, {"uuid": "240b3ec9-bc79-4c17-a8ee-8a8a425aa703", "name": "a68403b6-c7d7-45d0-83a6-4cfb97dc1f03_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.331677082668279, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10958157805626084, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c529a6f8-27f2-45db-aa1e-b8735c436127", "name": "928f825a-6ba2-4c81-a7c3-16861b88d2fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "240b3ec9-bc79-4c17-a8ee-8a8a425aa703"}}}]}, {"uuid": "51fa4197-1ba0-4eb2-b976-cb70045c9dfc", "name": "load_p1rlv19701_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b5d936f-b3e0-408e-aabd-d3ebb7b869b0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c529a6f8-27f2-45db-aa1e-b8735c436127"}}}}, {"uuid": "156a0ac9-458f-4c46-a04e-17ab1c6a23b4", "name": "932c9135-e467-4500-aee5-e3c7f125befa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 10.082274628538993, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.081607403669262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "326677db-6a41-4e8b-980e-90d10d1b78e7", "name": "60006b6a-3bcf-4371-a609-3fc2fb90e38a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "156a0ac9-458f-4c46-a04e-17ab1c6a23b4"}}}]}, {"uuid": "f9d708c9-eff7-4751-bcfa-65f0229b06c6", "name": "load_p1rlv19702_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37f72c85-61f7-4a42-94b0-6a627195458c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "326677db-6a41-4e8b-980e-90d10d1b78e7"}}}}, {"uuid": "42ff104e-d487-488b-8198-ae0df3abe8a3", "name": "6210e0b1-6210-4b7e-ab87-a9bed2bc7dc2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 10.082274628538993, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.081607403669262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0bdc9d7e-fba8-49d4-9a57-658e2eb6cdd9", "name": "c227d2e3-0c90-4d1c-8c71-cc21d84664af", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "42ff104e-d487-488b-8198-ae0df3abe8a3"}}}]}, {"uuid": "6c4ddb26-7f82-4578-95a1-80c652ba322a", "name": "load_p1rlv19702_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37f72c85-61f7-4a42-94b0-6a627195458c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0bdc9d7e-fba8-49d4-9a57-658e2eb6cdd9"}}}}, {"uuid": "3184dfb6-fe85-425b-8a2c-c8fcabee3cd9", "name": "434fc340-de1b-4a82-8747-2248052d2c85_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3786182488338723, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5359363058124609, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b2355f90-4b19-4f76-80f4-adbeb95f2861", "name": "e61cb651-ad75-433a-9e9b-e9b2fda0facc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3184dfb6-fe85-425b-8a2c-c8fcabee3cd9"}}}]}, {"uuid": "dd16986e-9178-4da5-94b5-abcd4a1cc80e", "name": "load_p1rlv20064_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aaea76fa-797e-46c5-a70f-a973977db841"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b2355f90-4b19-4f76-80f4-adbeb95f2861"}}}}, {"uuid": "3feb125e-0d30-4fa3-82b5-0a90a68f4f14", "name": "875ba8f6-e4f4-4981-89ed-f27d39ef2d03_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3786182488338723, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5359363058124609, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "faf06bc4-7f26-4a7b-981a-687b60237334", "name": "d62f7ca0-6d08-4cd6-8386-a2ad5803c0a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3feb125e-0d30-4fa3-82b5-0a90a68f4f14"}}}]}, {"uuid": "57d2795d-d45e-4749-ac18-4571bed715e7", "name": "load_p1rlv20064_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aaea76fa-797e-46c5-a70f-a973977db841"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "faf06bc4-7f26-4a7b-981a-687b60237334"}}}}, {"uuid": "697fca7f-f900-4399-9c9d-b7205ca2b896", "name": "1d1f1f6b-373d-428a-802b-e75f3af3d344_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9024769844937937, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4778358547008617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c89f6f9b-6be1-4081-a28f-ed71a35d83d4", "name": "81dd230b-be00-4e12-8599-9ff89e8d8aeb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "697fca7f-f900-4399-9c9d-b7205ca2b896"}}}]}, {"uuid": "f79d6824-33e0-4ddd-951e-c7a5dac2dc56", "name": "load_p1rlv20065_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea48ffa1-bdb3-4c15-96c9-ff7d7f34824f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c89f6f9b-6be1-4081-a28f-ed71a35d83d4"}}}}, {"uuid": "ad82f3f6-4fb0-493e-93e1-77619dfd382d", "name": "3e63e9a2-9263-49c9-8ce1-3b47b443769f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9024769844937937, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4778358547008617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "73056679-3214-4d0f-83d7-ea183b641d86", "name": "bbc86f6c-acca-45bc-b5c8-5c8e39c6bde2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ad82f3f6-4fb0-493e-93e1-77619dfd382d"}}}]}, {"uuid": "3fa11059-f23c-4332-afc5-f519c6bc4dfa", "name": "load_p1rlv20065_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea48ffa1-bdb3-4c15-96c9-ff7d7f34824f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "73056679-3214-4d0f-83d7-ea183b641d86"}}}}, {"uuid": "82613dda-2b0e-4576-ae18-3bae3f4b0bc1", "name": "12d6d0c1-1c78-4fba-80b4-98cd493320f6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9149869461814677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5767582022429075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "785fa984-c159-4e43-95ba-4838988535f5", "name": "33e33e39-b784-4951-a35e-45fe11e0de3a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "82613dda-2b0e-4576-ae18-3bae3f4b0bc1"}}}]}, {"uuid": "c8b6dbe3-fffb-47f6-b40d-5d02da5b6d2b", "name": "load_p1rlv20066_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f450eeb4-3d87-4ae5-a6d6-958d7efd2712"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "785fa984-c159-4e43-95ba-4838988535f5"}}}}, {"uuid": "173dc49f-cf27-46a6-9b3c-0c661da60210", "name": "5bc0a30a-237a-4fd5-8bc2-85472c196b45_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9149869461814677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5767582022429075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f540a76d-b5bb-431a-b2f2-50d5e78ab247", "name": "378ad036-0bbd-4070-b526-a3133b72d989", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "173dc49f-cf27-46a6-9b3c-0c661da60210"}}}]}, {"uuid": "db1b57aa-7de9-440d-883d-9651cdeae0a4", "name": "load_p1rlv20066_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f450eeb4-3d87-4ae5-a6d6-958d7efd2712"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f540a76d-b5bb-431a-b2f2-50d5e78ab247"}}}}, {"uuid": "2e8cf59c-6701-435e-8544-46ba106c78c7", "name": "8033911c-8184-4264-a0e0-42e5f03c32bf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1800d4d6-8a1e-44bf-ad2f-c6feda9f0b59", "name": "d8ec233b-e55b-463f-83ae-b0ae42abe0e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2e8cf59c-6701-435e-8544-46ba106c78c7"}}}]}, {"uuid": "1e865edd-ffaa-43ba-8b6e-a1d20c8ff803", "name": "load_p1rlv20067_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66a710fb-26c7-4465-b7ea-43ec107008dc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1800d4d6-8a1e-44bf-ad2f-c6feda9f0b59"}}}}, {"uuid": "92818016-ab6d-4337-8604-dcd511bd4151", "name": "2b659a4c-5e5c-44b8-96c0-52aac0b9da6c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a6c90a3d-94da-42ea-be63-43fde770dfde", "name": "f4b0e80f-9d14-4c13-8d38-047e9c58748d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "92818016-ab6d-4337-8604-dcd511bd4151"}}}]}, {"uuid": "7b858e2b-5879-4899-adc7-9d076a7f0ef4", "name": "load_p1rlv20067_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66a710fb-26c7-4465-b7ea-43ec107008dc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a6c90a3d-94da-42ea-be63-43fde770dfde"}}}}, {"uuid": "7677d201-3380-417a-9a52-9ef8fa9dfee1", "name": "63199bcf-5a1a-47bc-8d0a-44308165240b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9909c8b7-5b23-4575-9321-50732255db2a", "name": "3b9e654b-3b09-4b7c-b5b8-3f4660f31a85", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7677d201-3380-417a-9a52-9ef8fa9dfee1"}}}]}, {"uuid": "4152a1b5-d3f7-42db-9171-67392eaf7efd", "name": "load_p1rlv20068_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0b689f0-d4b1-4419-bff8-f72436625c60"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9909c8b7-5b23-4575-9321-50732255db2a"}}}}, {"uuid": "3e63513a-bb72-4d31-a2f9-70ec25c0b612", "name": "9b4bfbff-5ae6-4715-abfa-3af5790cc2d2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8943da66-5e87-482c-b323-437b555f1300", "name": "e7d84638-533e-4bd0-ae06-10a0dd73c4ab", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3e63513a-bb72-4d31-a2f9-70ec25c0b612"}}}]}, {"uuid": "3a0d0e67-4e45-466a-a48b-e5f651e188f6", "name": "load_p1rlv20068_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0b689f0-d4b1-4419-bff8-f72436625c60"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8943da66-5e87-482c-b323-437b555f1300"}}}}, {"uuid": "5605eca0-70bb-4c8b-956a-95ff334d8a43", "name": "f301133a-2df9-4eaf-80fe-f3b6c5d7880f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4037437915385973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5086059213404144, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "273da72e-70f8-4e20-b811-1d5aa8ac1840", "name": "f6722d02-839c-40da-add4-3dd5022b89e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5605eca0-70bb-4c8b-956a-95ff334d8a43"}}}]}, {"uuid": "efba0dc4-178b-4e97-82ec-7abb378997a4", "name": "load_p1rlv20069_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f0e3c74-2d63-4612-b0e5-d986ebee0086"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "273da72e-70f8-4e20-b811-1d5aa8ac1840"}}}}, {"uuid": "d8cb5421-7324-4513-b981-cd8ecdbea96f", "name": "27462fda-ccf8-499d-9b18-ca37ec941ee7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4037437915385973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5086059213404144, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1988d2a9-1029-4430-9f27-d5a16a35948c", "name": "9e4309a5-8321-4913-b06e-df37e6c2ff78", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d8cb5421-7324-4513-b981-cd8ecdbea96f"}}}]}, {"uuid": "398b0ec5-319c-4b3a-acb2-211ad4bd8015", "name": "load_p1rlv20069_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f0e3c74-2d63-4612-b0e5-d986ebee0086"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1988d2a9-1029-4430-9f27-d5a16a35948c"}}}}, {"uuid": "3ba36142-8efd-4af0-aabe-3d6c4e896e98", "name": "19143221-bbf3-412f-a922-844fb1f84b47_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1342890945582846, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10427649324668606, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4beddc3f-4f50-4de9-98bd-a0a3c47d55bb", "name": "420dc19a-c423-4269-929b-8e02f608bb34", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3ba36142-8efd-4af0-aabe-3d6c4e896e98"}}}]}, {"uuid": "ea4428f7-8e83-4552-88eb-60da17163578", "name": "load_p1rlv20070_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "571a4c92-95b6-4bc0-a25d-0d9239a41a89"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4beddc3f-4f50-4de9-98bd-a0a3c47d55bb"}}}}, {"uuid": "70456e11-39d7-47ac-b13e-e03e80311b70", "name": "3281dec8-098a-4ae7-be46-083646516e30_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1342890945582846, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10427649324668606, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4afa5e1a-3342-4e5a-83e8-598613d982bc", "name": "55e58dec-bb57-497a-b7ce-60d7f8574200", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "70456e11-39d7-47ac-b13e-e03e80311b70"}}}]}, {"uuid": "bc306be1-27e3-49cd-a6f3-ed5053de4e79", "name": "load_p1rlv20070_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "571a4c92-95b6-4bc0-a25d-0d9239a41a89"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4afa5e1a-3342-4e5a-83e8-598613d982bc"}}}}, {"uuid": "5f5aa3ad-0611-4475-ac97-843774f3e43a", "name": "388bb2a2-2f73-4610-b003-0829cde0cc95_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.025235929487997, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.9672019739719726, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "497e18cb-741a-46d2-93b0-dcb6dfbbb0ee", "name": "3810dbc5-14a3-413a-9555-92bd8326934b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5f5aa3ad-0611-4475-ac97-843774f3e43a"}}}]}, {"uuid": "6fddd001-4af1-4f25-86b8-830cf26fd999", "name": "load_p1rlv20071_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07f95ba5-92dd-465f-a38d-8e878243262b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "497e18cb-741a-46d2-93b0-dcb6dfbbb0ee"}}}}, {"uuid": "badae621-2271-4fbb-92b9-b7997198bc09", "name": "91f81205-3a31-4aeb-9c65-2bdb639fdc05_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.025235929487997, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.9672019739719726, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "686825c9-98a4-4205-ad4f-b655f3770986", "name": "be7d6cf5-80ec-45c1-9e63-37840f8f0eb5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "badae621-2271-4fbb-92b9-b7997198bc09"}}}]}, {"uuid": "09ab72cc-9134-4f4c-9d62-e7368620535e", "name": "load_p1rlv20071_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07f95ba5-92dd-465f-a38d-8e878243262b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "686825c9-98a4-4205-ad4f-b655f3770986"}}}}, {"uuid": "29885444-289e-4567-ac79-716f71b96499", "name": "d6cacb35-de42-4a55-960a-d2fcc20768b0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7653657521185364, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4426471780914222, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "23605292-f6c1-413b-959f-537dfae499e0", "name": "eb57cc4b-8ee1-44ab-a060-0031eb2d1e1a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "29885444-289e-4567-ac79-716f71b96499"}}}]}, {"uuid": "ea97d3d0-d113-42a9-8f4c-98ccd4431741", "name": "load_p1rlv20130_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ffc82be6-f3f8-4a68-b6e6-da60b137329c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "23605292-f6c1-413b-959f-537dfae499e0"}}}}, {"uuid": "628949c4-d977-44b9-83b5-dfc1b83a448b", "name": "a30ce11a-0069-4dc4-9a77-50344fff2ff4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7653657521185364, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4426471780914222, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a61035e4-5d72-4fb3-9918-8fd2bea3a19e", "name": "a97b7f72-290e-4cc7-942a-142650c7bd59", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "628949c4-d977-44b9-83b5-dfc1b83a448b"}}}]}, {"uuid": "814285a8-0508-4c27-b4cd-6e37590517af", "name": "load_p1rlv20130_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ffc82be6-f3f8-4a68-b6e6-da60b137329c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a61035e4-5d72-4fb3-9918-8fd2bea3a19e"}}}}, {"uuid": "37974511-b79e-4aa4-925a-ae52e6643350", "name": "02ac4d7e-f9c1-4888-8e64-96658f31aa7a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1976836424562762, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1051220183522544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "19a3a383-8f39-431d-a32e-0dfac9c66e47", "name": "4716de37-396d-4f84-9047-19015fc4b6f4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "37974511-b79e-4aa4-925a-ae52e6643350"}}}]}, {"uuid": "67877203-07fb-4971-969c-ca1db78cc7c1", "name": "load_p1rlv20138_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d635a151-2d13-47e9-8043-a214415a5b5e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "19a3a383-8f39-431d-a32e-0dfac9c66e47"}}}}, {"uuid": "329f48ca-3283-47e6-9989-c954e7417b71", "name": "f51afa32-de0f-47ab-a4c2-33c692d05346_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1976836424562762, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1051220183522544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "231b0252-b3b4-443d-99cc-1d0e0bb83657", "name": "e5aa4617-1d5e-460f-9043-0d7d915adec8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "329f48ca-3283-47e6-9989-c954e7417b71"}}}]}, {"uuid": "68a7350c-507f-4869-8bad-6bd0a7069723", "name": "load_p1rlv20138_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d635a151-2d13-47e9-8043-a214415a5b5e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "231b0252-b3b4-443d-99cc-1d0e0bb83657"}}}}, {"uuid": "77e49f4b-b3d3-40b3-834f-4c5168226a08", "name": "5fd864fc-b3a0-438c-9346-f231f66958a9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.839175601618853, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4557221316666175, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "78eab5a8-b3fc-48e7-ac43-fd2dd2da903e", "name": "1f056fd1-addf-4713-8e1b-327857a8743d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "77e49f4b-b3d3-40b3-834f-4c5168226a08"}}}]}, {"uuid": "0667c28e-dd8f-4765-b149-bc0a11a22f81", "name": "load_p1rlv20146_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d615e93-a289-41ec-bda0-3b72bf15677e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "78eab5a8-b3fc-48e7-ac43-fd2dd2da903e"}}}}, {"uuid": "506ef5e7-43e3-4523-9e28-9b4722bf0634", "name": "428b8f72-9bcb-4e02-98fc-1659b2b540e2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.839175601618853, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4557221316666175, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c30682c8-b30f-44c9-908c-fc579a66c330", "name": "1fcbb4ac-279f-46a5-868c-3e5365b9bcc8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "506ef5e7-43e3-4523-9e28-9b4722bf0634"}}}]}, {"uuid": "9b0e659d-e509-4ce2-ba46-cca8bfc2a219", "name": "load_p1rlv20146_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d615e93-a289-41ec-bda0-3b72bf15677e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c30682c8-b30f-44c9-908c-fc579a66c330"}}}}, {"uuid": "8e9732f9-6379-4fd0-ac97-9181c8e829d9", "name": "03898ed5-122c-4c49-b780-cd35835216b3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "afd04a47-3d32-4c66-a95c-2d82fcf9cb75", "name": "913241c2-4cb9-4656-aa6f-c928a21d86df", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8e9732f9-6379-4fd0-ac97-9181c8e829d9"}}}]}, {"uuid": "536437b6-5ff9-472d-a83d-fb5675e57c4a", "name": "load_p1rlv20147_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16b2add7-6a6d-4359-ad6f-f60edf435a4c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "afd04a47-3d32-4c66-a95c-2d82fcf9cb75"}}}}, {"uuid": "3731ebe0-ebd8-47e6-9f23-11292962762b", "name": "76137a33-2e13-4efa-aa08-b7f3288379e1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dc3fa00c-5670-4fcc-914d-cb2e2c2380c9", "name": "6048944f-1622-4c7a-9d8b-15c68d67f7dc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3731ebe0-ebd8-47e6-9f23-11292962762b"}}}]}, {"uuid": "598879fc-5988-40ba-b8b1-b7f009c0bd4b", "name": "load_p1rlv20147_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16b2add7-6a6d-4359-ad6f-f60edf435a4c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dc3fa00c-5670-4fcc-914d-cb2e2c2380c9"}}}}, {"uuid": "f10a8db9-e4a7-409d-9fe0-0a9c827524fe", "name": "d2ab8b89-50f4-4fe5-b697-631e8ee4a2bb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7025097104959883, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.553651846257773, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "09f7234d-2f4c-442f-b595-e940779f8e6f", "name": "18d573c6-341a-43af-9f4b-a773e08d4034", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f10a8db9-e4a7-409d-9fe0-0a9c827524fe"}}}]}, {"uuid": "9cd2c69b-6267-4d9c-8085-cee3d6348e34", "name": "load_p1rlv20148_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4a0c2f2-f75e-4c9c-b3f7-d8d9ada9cb82"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "09f7234d-2f4c-442f-b595-e940779f8e6f"}}}}, {"uuid": "662c15fd-8273-4d2a-826c-d63dd0d541a0", "name": "4d2a8b9a-7a08-41c2-9a1f-d7be80a8fc28_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7025097104959883, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.553651846257773, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "13b2ca4a-12c6-4d03-93e8-8035a24731c4", "name": "1accd70c-77fe-4a8b-9f62-a48f71f4108a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "662c15fd-8273-4d2a-826c-d63dd0d541a0"}}}]}, {"uuid": "7dcaeb95-0db1-4839-81dd-b2ffa143a131", "name": "load_p1rlv20148_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4a0c2f2-f75e-4c9c-b3f7-d8d9ada9cb82"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "13b2ca4a-12c6-4d03-93e8-8035a24731c4"}}}}, {"uuid": "3b7d566a-fd60-40c0-888b-37195221ec56", "name": "1eb5f63e-f4c5-47bc-880a-0419ffdc4f60_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.277248598662887, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.143515736159974, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e3821511-30df-465b-acb5-3df5a9431900", "name": "5a7edf86-266b-48de-b000-e3261d2d65ca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3b7d566a-fd60-40c0-888b-37195221ec56"}}}]}, {"uuid": "682c2dbc-2d9f-46b3-a0fc-e78562e8149f", "name": "load_p1rlv20151_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "956f4975-7383-4e0b-9114-d333a6ec4005"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e3821511-30df-465b-acb5-3df5a9431900"}}}}, {"uuid": "6bb11e99-c093-4512-9392-c9dd988042ea", "name": "0acfd7e0-8c71-493f-9322-f74be44fd197_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.277248598662887, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.143515736159974, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3e0146d7-6870-4a6e-a581-9c1c0b4e462b", "name": "5570bc04-89fc-468f-9de1-40cead4ef94f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6bb11e99-c093-4512-9392-c9dd988042ea"}}}]}, {"uuid": "dce30ee9-99e3-4096-a1d2-edfb09ca8731", "name": "load_p1rlv20151_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "956f4975-7383-4e0b-9114-d333a6ec4005"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3e0146d7-6870-4a6e-a581-9c1c0b4e462b"}}}}, {"uuid": "2101c4d2-a7bb-4ec5-a9e0-472a22d2b9ca", "name": "9375f020-eb43-4a91-90bb-7d3471fee0f3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "da803e70-4bd3-4d0f-8a3b-890e59ec93c0", "name": "b8408681-1c10-4ebc-99ce-10c4bb6796e5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2101c4d2-a7bb-4ec5-a9e0-472a22d2b9ca"}}}]}, {"uuid": "e8b7955f-7191-4b62-a82e-079f0f2abdc7", "name": "load_p1rlv20153_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef20846d-d685-4c65-8dfb-bc23317501c5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "da803e70-4bd3-4d0f-8a3b-890e59ec93c0"}}}}, {"uuid": "1322af1c-d5fb-4850-be2e-41cdd0694ee3", "name": "c062e370-2bf3-4980-8f36-b57052d378a5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9353a53d-fd76-4406-82a0-30c0d857bcd0", "name": "f05ecb8f-2027-458d-9583-302b49f3a150", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1322af1c-d5fb-4850-be2e-41cdd0694ee3"}}}]}, {"uuid": "19356f3f-57d5-443b-94c5-61013aa67221", "name": "load_p1rlv20153_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef20846d-d685-4c65-8dfb-bc23317501c5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9353a53d-fd76-4406-82a0-30c0d857bcd0"}}}}, {"uuid": "582666e3-88bd-4406-b4c6-e73bb4b91ba0", "name": "d0e74089-9406-42cb-968c-941ee84e139e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1698158732703443, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8490689598373361, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "53567545-db94-412e-add3-0c889695de31", "name": "8e64aa07-d1a1-4ea2-907b-ace2c89cb4c5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "582666e3-88bd-4406-b4c6-e73bb4b91ba0"}}}]}, {"uuid": "d8613fd8-c758-4c40-98a7-b36993886851", "name": "load_p1rlv20154_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02f2e50e-d42d-47d1-9274-d840042b64d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "53567545-db94-412e-add3-0c889695de31"}}}}, {"uuid": "40f79b36-4145-4613-88ba-89a19ec6e0bf", "name": "f0e82a30-446e-4f1d-9f99-5d6ca2981ced_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1698158732703443, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8490689598373361, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0edebbfd-e6b6-4891-a964-32309e76baf4", "name": "298418b6-5cc5-4ffd-9476-59d005dbfdaa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "40f79b36-4145-4613-88ba-89a19ec6e0bf"}}}]}, {"uuid": "01e845a4-e721-4c3f-8d26-7cb4412b84df", "name": "load_p1rlv20154_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02f2e50e-d42d-47d1-9274-d840042b64d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0edebbfd-e6b6-4891-a964-32309e76baf4"}}}}, {"uuid": "b32c0a9a-d334-4681-857d-fd8ab3a6549d", "name": "cf52475d-8d2b-425a-a6b6-6bd1227771c0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5577393205082823, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5087722503146331, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "01689471-6c73-4ce9-9bac-cb43ee06a20c", "name": "e5d46a68-b1fc-4ec5-86d7-dd92c1328c97", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b32c0a9a-d334-4681-857d-fd8ab3a6549d"}}}]}, {"uuid": "0819d7bb-f90e-43bd-b41a-14b444d08141", "name": "load_p1rlv20160_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27dfea92-734e-49d3-b245-dc933df66889"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "01689471-6c73-4ce9-9bac-cb43ee06a20c"}}}}, {"uuid": "27394fdb-622e-44b6-81d5-1eb9981f00c6", "name": "6e7dcfe2-6b4d-4558-9672-5295b6aa6270_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5577393205082823, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5087722503146331, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "32efff42-1c9a-4a6a-843c-5a318886d726", "name": "4e734bd3-f26b-482b-a8a8-49499875d26a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "27394fdb-622e-44b6-81d5-1eb9981f00c6"}}}]}, {"uuid": "1d5eca10-7bad-482f-80c6-247f8151e31f", "name": "load_p1rlv20160_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27dfea92-734e-49d3-b245-dc933df66889"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "32efff42-1c9a-4a6a-843c-5a318886d726"}}}}, {"uuid": "0755fb9f-6568-4c32-b652-1f92318543fe", "name": "e5463d44-becb-400d-ba47-359a9bf4eed7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.826891988709754, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.5850639012710004, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9906031f-a5da-425e-addb-376808d02468", "name": "b4611dd5-8fd7-4751-bbe7-21bc6d40f9da", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0755fb9f-6568-4c32-b652-1f92318543fe"}}}]}, {"uuid": "f76f88c6-153e-4c33-a478-49634987fdd8", "name": "load_p1rlv20161_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11a125b8-023c-4748-98a9-d74e9e0a7d23"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9906031f-a5da-425e-addb-376808d02468"}}}}, {"uuid": "440780fa-ac19-42bc-b756-9c76d5ee9ca9", "name": "e4e3cfe7-e4c9-4af4-9494-7498213372f2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.826891988709754, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.5850639012710004, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cd182b10-c001-4a5b-9e43-44dc7c455daa", "name": "6753785b-9a38-40d4-ba64-dc7aeda6e217", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "440780fa-ac19-42bc-b756-9c76d5ee9ca9"}}}]}, {"uuid": "befc5031-d584-4387-97d0-6d05dd3b0f94", "name": "load_p1rlv20161_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11a125b8-023c-4748-98a9-d74e9e0a7d23"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cd182b10-c001-4a5b-9e43-44dc7c455daa"}}}}, {"uuid": "2b9916e3-1cc3-40c2-b106-100fbca32bc4", "name": "f482b61d-a170-49f3-adcd-14b9a9aaa2d0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "12c1a588-267c-4df0-92de-712705362eb2", "name": "d546f682-d596-48d1-8a10-beb069f9b663", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2b9916e3-1cc3-40c2-b106-100fbca32bc4"}}}]}, {"uuid": "3186e30a-1daf-47a1-b3a7-7de94b934a1e", "name": "load_p1rlv20163_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e938635b-e0d2-4e1b-a312-5a8f51e1dd7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "12c1a588-267c-4df0-92de-712705362eb2"}}}}, {"uuid": "40513ecc-0631-4feb-bff0-b823f8acbaee", "name": "c21439ba-4ca7-42c0-b8f4-7897a3e295b8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8bb247fa-584b-4826-a3eb-332fb347f14d", "name": "7dbadad6-bb74-4c3f-be9c-5e5f75360e4a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "40513ecc-0631-4feb-bff0-b823f8acbaee"}}}]}, {"uuid": "973dea5e-dd8c-415b-8833-e13c3546485a", "name": "load_p1rlv20163_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e938635b-e0d2-4e1b-a312-5a8f51e1dd7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8bb247fa-584b-4826-a3eb-332fb347f14d"}}}}, {"uuid": "fc046cf8-edf0-4a1f-8754-5be4bb0b4419", "name": "9aa214a9-ac1c-4ac4-be04-d682e3102515_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3462824541838714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7901197550518754, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82ff972c-2cb6-4f7b-bfe3-e8685c86e393", "name": "5a0f9488-66ab-41bf-876b-3a5ad925add7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fc046cf8-edf0-4a1f-8754-5be4bb0b4419"}}}]}, {"uuid": "61c13976-6f8e-4718-8f43-36f89629245a", "name": "load_p1rlv20182_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20f93381-3834-4265-b1ec-5767d171ce0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "82ff972c-2cb6-4f7b-bfe3-e8685c86e393"}}}}, {"uuid": "f5c5ca8e-be6e-4b48-a905-8cd79528f7df", "name": "e7161faf-4531-4d2d-b504-93f71e0fe967_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3462824541838714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7901197550518754, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4eeebcf3-056a-4f59-af07-063d2c3aebeb", "name": "9d0e8107-35e5-4c97-8abe-24118b0ed9d9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f5c5ca8e-be6e-4b48-a905-8cd79528f7df"}}}]}, {"uuid": "812e9359-28ca-4c4c-846e-f1c369d693f9", "name": "load_p1rlv20182_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20f93381-3834-4265-b1ec-5767d171ce0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4eeebcf3-056a-4f59-af07-063d2c3aebeb"}}}}, {"uuid": "a9830c46-efc9-4e6e-9226-0f99af835107", "name": "b61530f2-b813-4330-9c11-d81eedb917b0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8755168938707782, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2009555085079469, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ee98b128-df25-43d4-87c1-f8fe889abcaa", "name": "2142c271-ebf2-4614-8dde-8b98e597f647", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a9830c46-efc9-4e6e-9226-0f99af835107"}}}]}, {"uuid": "88397929-e8cf-468a-ac8a-28e3eb47a3a0", "name": "load_p1rlv20185_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "646058a3-cda7-4723-bd0f-05d305fe7c11"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ee98b128-df25-43d4-87c1-f8fe889abcaa"}}}}, {"uuid": "0d3ad7f6-d3a8-4024-b3c9-bbb592967dab", "name": "0dde55ff-6f5f-4f03-9926-2b0a217728a2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8755168938707782, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2009555085079469, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "277ea683-fcbe-4395-9b33-9052b99b4481", "name": "6177fe72-01fb-4006-b437-863e53d5a251", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0d3ad7f6-d3a8-4024-b3c9-bbb592967dab"}}}]}, {"uuid": "2fe7edb6-18ed-4a59-9a6f-bfb4d2f50581", "name": "load_p1rlv20185_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "646058a3-cda7-4723-bd0f-05d305fe7c11"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "277ea683-fcbe-4395-9b33-9052b99b4481"}}}}, {"uuid": "6e1a9f5a-f7a2-433b-af26-26c9c15d62fe", "name": "8c5d2dcb-b540-4936-9483-c1517b9a0575_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.554325896527151, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5828877012431191, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6d786114-559e-4567-b1a9-491f2ba465f9", "name": "0c229e2e-de38-4ee7-ac97-67c3b5c717cc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6e1a9f5a-f7a2-433b-af26-26c9c15d62fe"}}}]}, {"uuid": "5847e5be-d646-444e-8211-899235c6ef51", "name": "load_p1rlv20188_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abb24254-be79-45d4-8d9b-246b3e89c00f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6d786114-559e-4567-b1a9-491f2ba465f9"}}}}, {"uuid": "3631cd29-11c0-4a70-b9e6-6177be8b554f", "name": "7f4d2eb1-a8d4-4749-ab9e-e92a0cc31f26_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.554325896527151, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5828877012431191, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "115437c8-e691-44ea-9e83-6dc374bc9259", "name": "5b5dfff3-f56a-4af6-b785-50418eaaec42", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3631cd29-11c0-4a70-b9e6-6177be8b554f"}}}]}, {"uuid": "3f45176f-1df3-4292-bc58-2721e0dee7ef", "name": "load_p1rlv20188_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abb24254-be79-45d4-8d9b-246b3e89c00f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "115437c8-e691-44ea-9e83-6dc374bc9259"}}}}, {"uuid": "49562469-1301-4363-95cd-3046593c0adb", "name": "fcd3d06a-e2dc-452a-b50c-2fbaf06ff7b6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0363799452523006, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8773696756055507, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "da655a3b-6207-4105-b2b5-d69624f20812", "name": "6b8dbe70-8270-40b3-a00b-ecd9df03bb39", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "49562469-1301-4363-95cd-3046593c0adb"}}}]}, {"uuid": "7cf357d4-27c1-4541-8cd7-0855ad1b1dc5", "name": "load_p1rlv20277_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb7a8747-a076-469c-a150-35f6763157ec"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "da655a3b-6207-4105-b2b5-d69624f20812"}}}}, {"uuid": "48452f3a-9d18-4066-8409-178fb47c9120", "name": "369c1a0f-a6e3-4469-a1b5-0acd2f52c8e1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0363799452523006, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8773696756055507, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2f45548d-b2ca-4afd-a1d4-558c5eddf0ff", "name": "73e856f3-f8ba-4274-bcc0-4db94de2ad3f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "48452f3a-9d18-4066-8409-178fb47c9120"}}}]}, {"uuid": "a6be9839-5c1b-4d4f-b05c-c986bb22e30b", "name": "load_p1rlv20277_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb7a8747-a076-469c-a150-35f6763157ec"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2f45548d-b2ca-4afd-a1d4-558c5eddf0ff"}}}}, {"uuid": "d41bcd97-b083-4899-8741-6defb5b6dbb0", "name": "23084baa-fb64-4ed3-a74b-f025044ac26b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1813646779377422, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20173832232537287, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9d614edf-f3c2-4712-99e3-094059223132", "name": "e5308187-bb32-4cfb-8b2b-1f60d283de51", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d41bcd97-b083-4899-8741-6defb5b6dbb0"}}}]}, {"uuid": "a1a5093b-f3d8-4fd9-b381-116dec74cf27", "name": "load_p1rlv20281_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f23405b-432f-45ff-a7b1-0b7147cddfc8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9d614edf-f3c2-4712-99e3-094059223132"}}}}, {"uuid": "71c2e802-a315-4089-9729-f73dd906daee", "name": "b4f5e80a-6212-47ed-9404-91a51057ecd2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1813646779377422, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20173832232537287, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b9ba64f9-1cbc-4a5d-be48-20111b1287ef", "name": "8acbf98f-0273-431c-abf0-20ea79a0bc28", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "71c2e802-a315-4089-9729-f73dd906daee"}}}]}, {"uuid": "1755aad6-21f9-4bb5-b0d6-a7ae5e6b3ad5", "name": "load_p1rlv20281_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f23405b-432f-45ff-a7b1-0b7147cddfc8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b9ba64f9-1cbc-4a5d-be48-20111b1287ef"}}}}, {"uuid": "689f32c9-d186-48b3-a8ec-429949952c0f", "name": "01463a59-3f92-4fbd-baed-8cf8b363221e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2766983969851713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5028612878254624, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3f980f97-c5a3-4719-8006-0b9d4aa8b5a3", "name": "3ba769f6-84c3-4d18-b2a7-f90181ad0bc0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "689f32c9-d186-48b3-a8ec-429949952c0f"}}}]}, {"uuid": "e1d8f0c8-3c29-4b77-acc9-9b57270a4d1a", "name": "load_p1rlv20284_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25837ab0-0fb8-4346-94ad-561ff9ff7f0c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3f980f97-c5a3-4719-8006-0b9d4aa8b5a3"}}}}, {"uuid": "97a52d88-a34a-4ad5-b103-602e9e4264e9", "name": "0200df23-bb54-4357-b643-2d48e26695e3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2766983969851713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5028612878254624, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7902ab99-1ca8-45de-a413-dd2372e8f08c", "name": "42525e2f-3479-401f-b10c-276c5855ea32", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "97a52d88-a34a-4ad5-b103-602e9e4264e9"}}}]}, {"uuid": "5c7ebc0b-5d52-45c2-9464-3daa5289b5de", "name": "load_p1rlv20284_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25837ab0-0fb8-4346-94ad-561ff9ff7f0c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7902ab99-1ca8-45de-a413-dd2372e8f08c"}}}}, {"uuid": "d3ea8fe8-e245-4310-bdcd-c00b9ae6a0a0", "name": "d3bf749d-369b-4f9a-a81f-d7cdd696a223_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.883515343353138, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18989418857380705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c49e716e-4a88-4679-aae4-91b2e7bfd7af", "name": "a8a5d2be-83a1-4e95-8713-add634e266c8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d3ea8fe8-e245-4310-bdcd-c00b9ae6a0a0"}}}]}, {"uuid": "73cd87f9-90e9-426c-8cdb-dd9fae4321f5", "name": "load_p1rlv20296_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a8ae6dc-884d-48d8-9995-fe3936ad019c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c49e716e-4a88-4679-aae4-91b2e7bfd7af"}}}}, {"uuid": "e9a77572-7cc3-44e3-aa73-162851150d07", "name": "ed77ba44-c96a-4c66-b55e-6ad9b009db3e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.883515343353138, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18989418857380705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6e3749ca-15f3-4e70-ba98-cb72a5d62b4d", "name": "23aebaf6-1ac9-49fc-8bff-f7387b987557", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e9a77572-7cc3-44e3-aa73-162851150d07"}}}]}, {"uuid": "209538f5-f332-4d02-adf0-a57fe9255933", "name": "load_p1rlv20296_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a8ae6dc-884d-48d8-9995-fe3936ad019c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6e3749ca-15f3-4e70-ba98-cb72a5d62b4d"}}}}, {"uuid": "674e61df-acfa-4ba9-a25c-a0ef9c3d7234", "name": "52a05c32-4595-4e35-8b75-9dfc10adb02f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.882765489125589, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7706550587664386, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3d96ba4a-9748-4117-9115-0ec6e4a84d97", "name": "f149b8f3-ffe6-4eb8-9c70-3037d949c8ce", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "674e61df-acfa-4ba9-a25c-a0ef9c3d7234"}}}]}, {"uuid": "e583e114-43fa-4279-8479-0a9b6f760cd8", "name": "load_p1rlv20300_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da62d78e-e221-423a-8da0-8d36ce1f7508"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3d96ba4a-9748-4117-9115-0ec6e4a84d97"}}}}, {"uuid": "231f7ff9-e2a6-422f-868e-484d14a19fb3", "name": "61ae5d4b-8e33-4476-9faf-c4e177b90cfc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.882765489125589, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7706550587664386, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "814c2e34-5564-4e3c-b825-299f449c1549", "name": "6647d065-688f-4a0c-be0e-57e96810df79", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "231f7ff9-e2a6-422f-868e-484d14a19fb3"}}}]}, {"uuid": "8167385d-15e1-43ed-87a9-157820a44468", "name": "load_p1rlv20300_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da62d78e-e221-423a-8da0-8d36ce1f7508"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "814c2e34-5564-4e3c-b825-299f449c1549"}}}}, {"uuid": "a69441e7-20bf-4633-9680-549d96bc42b5", "name": "e26b65fb-b834-4d3d-abd7-e0398420cb28_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.693241087582845, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5112522017919784, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10eadc14-2c10-4e7e-9c68-5db44d506d7d", "name": "9dacf371-4b31-4a2a-a482-d985e56df868", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a69441e7-20bf-4633-9680-549d96bc42b5"}}}]}, {"uuid": "c60d84a8-585f-4b23-9e8f-683aaaf84f41", "name": "load_p1rlv20309_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e5718ad-0b70-4ea4-b2f2-31f0ea5c5d5b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10eadc14-2c10-4e7e-9c68-5db44d506d7d"}}}}, {"uuid": "3845555f-4b62-4dfc-b4b7-37d8efd82575", "name": "604a9fac-d7a2-44b0-8c14-02e979a21980_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.693241087582845, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5112522017919784, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3061bc64-6954-4cb0-af8c-42bea15eb1ff", "name": "8711a927-6ff3-4819-b6d6-1e02c035eaeb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3845555f-4b62-4dfc-b4b7-37d8efd82575"}}}]}, {"uuid": "d2319eca-b2e2-493f-bbc5-9c465e6d19f1", "name": "load_p1rlv20309_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e5718ad-0b70-4ea4-b2f2-31f0ea5c5d5b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3061bc64-6954-4cb0-af8c-42bea15eb1ff"}}}}, {"uuid": "ab26b536-8e98-4cbd-826e-632038c7aa68", "name": "43a3ddac-87b5-4f7d-a777-e36b7cd087a7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.771789007275423, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6748983225226206, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "94e5a2f6-c580-487f-b991-e648af18c2b3", "name": "789e3f04-ec58-4372-a305-0e7d67f232dd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ab26b536-8e98-4cbd-826e-632038c7aa68"}}}]}, {"uuid": "67d5a93f-9cc6-4996-875a-ead4a2259149", "name": "load_p1rlv20333_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c23afdc0-ab93-4d43-8eec-613eab21cd74"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "94e5a2f6-c580-487f-b991-e648af18c2b3"}}}}, {"uuid": "1f0b1832-82ee-4ba8-8223-466b960951ce", "name": "846779ae-8e22-4d09-81e5-17492a80c258_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.771789007275423, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6748983225226206, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ef8fd0ff-288b-430f-b0cf-cda84570432d", "name": "739f4418-858f-4ed2-9995-c7d33f959819", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1f0b1832-82ee-4ba8-8223-466b960951ce"}}}]}, {"uuid": "63ab5d3b-31a1-40da-b0d8-5e02c8252274", "name": "load_p1rlv20333_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c23afdc0-ab93-4d43-8eec-613eab21cd74"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ef8fd0ff-288b-430f-b0cf-cda84570432d"}}}}, {"uuid": "2c59ab6a-27f7-4bf4-b196-491740e3eea2", "name": "1bf779d5-b9fb-4c49-a1ec-8c5e9c95ad86_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4663769608466568, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5502546109327153, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f0b41a56-9e28-4e39-853a-5fd6b3a3f759", "name": "35f13eff-e9a2-464e-9b8c-a394a22fba9c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2c59ab6a-27f7-4bf4-b196-491740e3eea2"}}}]}, {"uuid": "947a6e02-28d8-48d0-a08b-2755c2ef0a5a", "name": "load_p1rlv20358_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b5d2dfa-895b-4afc-a7fe-449960adba41"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f0b41a56-9e28-4e39-853a-5fd6b3a3f759"}}}}, {"uuid": "f2d0f53c-e96d-4415-9be7-7c18d2921e78", "name": "1d8dc242-b4c0-4991-a303-dd2696fd8062_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4663769608466568, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5502546109327153, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "add10e60-b423-40da-9574-89fe3fd70430", "name": "dab80639-1aba-48f6-82a0-59a1e3a61146", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f2d0f53c-e96d-4415-9be7-7c18d2921e78"}}}]}, {"uuid": "1ff5e68d-e4ac-4cbf-ab60-fa72da086e84", "name": "load_p1rlv20358_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b5d2dfa-895b-4afc-a7fe-449960adba41"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "add10e60-b423-40da-9574-89fe3fd70430"}}}}, {"uuid": "b721e110-586f-4991-b001-e8231b9a661a", "name": "4f4600d5-3b68-43ae-9fc4-682eb9a82ec5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.234980013002153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7303750309107965, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "84307684-e352-4ed0-8167-f34fd87e6a0e", "name": "a37056e5-15cf-46ee-a399-2919d04cef17", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b721e110-586f-4991-b001-e8231b9a661a"}}}]}, {"uuid": "24a685f1-f697-42a7-8baf-26bd8d3a777c", "name": "load_p1rlv20432_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4b5327a-85a3-496c-859c-f887a38513cd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "84307684-e352-4ed0-8167-f34fd87e6a0e"}}}}, {"uuid": "cfe04cf1-1d36-49b4-8437-1c3cfb4ad9ac", "name": "fe88a424-87cc-4d87-8469-62f10e845aae_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.234980013002153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7303750309107965, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dad3dd9c-6e71-48c0-bfcf-864ab6075d33", "name": "5b53255a-f320-42bd-b033-28f0ee0d898d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cfe04cf1-1d36-49b4-8437-1c3cfb4ad9ac"}}}]}, {"uuid": "b338d19c-0240-4a2f-a921-41e0f09d9388", "name": "load_p1rlv20432_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4b5327a-85a3-496c-859c-f887a38513cd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dad3dd9c-6e71-48c0-bfcf-864ab6075d33"}}}}, {"uuid": "2f56313c-3d79-46a7-a0ca-9d045bd29bea", "name": "582f7ddf-5577-4b76-a74c-572604dea4bc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.875485744114147, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.294896241985991, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1702993d-c1f9-4973-b193-3a8585e423a0", "name": "c096483d-27aa-424a-ab54-603c3cb0b381", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2f56313c-3d79-46a7-a0ca-9d045bd29bea"}}}]}, {"uuid": "883a1c8e-13a5-43b7-8fcf-15e3d109de8d", "name": "load_p1rlv20450_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "006c2753-37b3-4b59-82a6-8ce95f316e26"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1702993d-c1f9-4973-b193-3a8585e423a0"}}}}, {"uuid": "ce653358-2d5e-4f72-b43b-295514bc1cad", "name": "cc6468ed-786c-4572-82a8-5d6b57b04a3b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.875485744114147, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.294896241985991, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "18b9c629-85b9-42dc-ab5d-6d5c3b3071cc", "name": "82ea8c9f-863a-4388-a0ae-d3d2203bccbc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ce653358-2d5e-4f72-b43b-295514bc1cad"}}}]}, {"uuid": "b534e7d7-118c-4848-95ae-fcc2f4ed6e5f", "name": "load_p1rlv20450_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "006c2753-37b3-4b59-82a6-8ce95f316e26"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "18b9c629-85b9-42dc-ab5d-6d5c3b3071cc"}}}}, {"uuid": "5b9b6951-75e2-4637-a256-d849e3b06acf", "name": "656a36cf-f25b-4120-8099-158fe0f59230_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b8a0bdaa-7756-4107-b440-71e5df460e62", "name": "18d974a3-94a5-4caa-bd9f-2a1e5338cd51", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b9b6951-75e2-4637-a256-d849e3b06acf"}}}]}, {"uuid": "dd86f627-1fdb-4186-8fd2-5a821ad6b167", "name": "load_p1rlv20451_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c37708d8-1e83-4e76-ac7f-0d29ba6b7c4e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b8a0bdaa-7756-4107-b440-71e5df460e62"}}}}, {"uuid": "2c4105ad-2941-4a5e-8da0-084fe4c47413", "name": "358342e3-0ff1-4fbe-bfe9-b931af7cada5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "11e14820-7282-4d71-a652-1df122e93ae3", "name": "ed38027a-bde9-4103-bada-f0cbe9f21e63", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2c4105ad-2941-4a5e-8da0-084fe4c47413"}}}]}, {"uuid": "d0489582-81ad-47e8-ac14-e3d9782482a9", "name": "load_p1rlv20451_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c37708d8-1e83-4e76-ac7f-0d29ba6b7c4e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "11e14820-7282-4d71-a652-1df122e93ae3"}}}}, {"uuid": "04a63073-b106-4c96-af0d-750e7142c296", "name": "3789b483-2c9e-4cdc-850b-1f6a72bcef77_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.250267265771566, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8009319586825154, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f16238df-3368-4a62-8c92-7c5c72897070", "name": "fa0828f4-8786-4eab-b890-f711c0f4100e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "04a63073-b106-4c96-af0d-750e7142c296"}}}]}, {"uuid": "81cb1766-7c52-4734-b2c2-41c66ce8a702", "name": "load_p1rlv20453_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4e21b79-d2be-4a53-be46-32331e61f89c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f16238df-3368-4a62-8c92-7c5c72897070"}}}}, {"uuid": "d5049aa4-9273-407c-94cf-05ca8a440bb5", "name": "9aed6232-19be-49ed-8f87-15b4a5c57259_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.250267265771566, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8009319586825154, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82923a7e-5484-4585-9ca1-a210dbd4353c", "name": "f8f24d31-bdc4-422b-bb31-6ea4a915fff6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d5049aa4-9273-407c-94cf-05ca8a440bb5"}}}]}, {"uuid": "3130ec59-302e-4764-b6ec-7a2c174c82fc", "name": "load_p1rlv20453_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4e21b79-d2be-4a53-be46-32331e61f89c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "82923a7e-5484-4585-9ca1-a210dbd4353c"}}}}, {"uuid": "5fed4409-884d-4852-aaca-6254e421f131", "name": "48f05232-d2cd-4c7f-b426-e33a74da8e37_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8249779386922644, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12555321354723425, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5cf1d9db-65c5-40e1-a2ad-8266c84ccbeb", "name": "45f27dfc-ed96-4912-abc5-76bb39a907a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5fed4409-884d-4852-aaca-6254e421f131"}}}]}, {"uuid": "d759ae69-49ba-4eae-9068-7d6580520328", "name": "load_p1rlv20455_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8934db59-0c39-4838-9f8c-59a563cd9d54"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5cf1d9db-65c5-40e1-a2ad-8266c84ccbeb"}}}}, {"uuid": "229b6a23-244e-4532-9a35-bca51bcf0c42", "name": "59d624f6-8c91-48de-bad6-4f0278258187_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8249779386922644, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12555321354723425, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cef84716-de5d-4d70-ac0d-8789997937fd", "name": "f1b9614f-d493-439e-8adb-16d290302ab6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "229b6a23-244e-4532-9a35-bca51bcf0c42"}}}]}, {"uuid": "dcfeb706-43bf-4843-a816-558d7581b181", "name": "load_p1rlv20455_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8934db59-0c39-4838-9f8c-59a563cd9d54"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cef84716-de5d-4d70-ac0d-8789997937fd"}}}}, {"uuid": "6d1cbd3e-0a5d-405e-b2a1-5a12b82418ab", "name": "7d23ff30-ed71-4481-9b7e-5f6e41217722_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8374792851175116, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3203908676737591, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "84f5cd6e-2311-496e-b43d-4ca722b1bd78", "name": "663baad0-b0d9-45a7-927e-a0e5745d093d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6d1cbd3e-0a5d-405e-b2a1-5a12b82418ab"}}}]}, {"uuid": "15618555-50c1-4539-9f13-79af73f29385", "name": "load_p1rlv20456_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7a43aa6-2be8-4320-8089-57d388633c6b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "84f5cd6e-2311-496e-b43d-4ca722b1bd78"}}}}, {"uuid": "3d0161c8-eb1c-4ee5-9650-143e945be3cf", "name": "0532cf22-4356-42b2-9e53-0041df647378_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8374792851175116, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3203908676737591, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e1f2743d-7186-44c8-8f9a-eaa189699efd", "name": "92bd0fa1-7f76-4bc0-9d50-9025b4331053", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3d0161c8-eb1c-4ee5-9650-143e945be3cf"}}}]}, {"uuid": "287913e4-5259-480f-8263-e9c579b303b3", "name": "load_p1rlv20456_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7a43aa6-2be8-4320-8089-57d388633c6b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e1f2743d-7186-44c8-8f9a-eaa189699efd"}}}}, {"uuid": "34dc3d17-22d5-4269-b173-57f37f258b5d", "name": "a7178ff2-912b-40c4-83e7-d36982eb2cf3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "daccca9a-4139-4678-8213-c2c1a0d5452b", "name": "c42dc409-047a-4727-b120-e73d258a5d04", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "34dc3d17-22d5-4269-b173-57f37f258b5d"}}}]}, {"uuid": "0427d862-2997-45d5-8577-931c32fbd39d", "name": "load_p1rlv20459_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dfcfdbf-0051-4eef-bea6-97446cee21e4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "daccca9a-4139-4678-8213-c2c1a0d5452b"}}}}, {"uuid": "945cb6b6-8779-42d6-9cb7-b12d175781b1", "name": "bdf587e2-5289-4da2-966b-c4c582a9b1eb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ef5f0664-db91-4bdd-8bb9-3db366347fb4", "name": "6b3f9973-e997-4894-b53c-4f7487109a22", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "945cb6b6-8779-42d6-9cb7-b12d175781b1"}}}]}, {"uuid": "4fa9fb29-e1fd-4f0c-9408-5b718718758e", "name": "load_p1rlv20459_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dfcfdbf-0051-4eef-bea6-97446cee21e4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ef5f0664-db91-4bdd-8bb9-3db366347fb4"}}}}, {"uuid": "401ed287-96c4-47ad-bb6b-c09376d9100b", "name": "fbb8c89b-8c5f-4ce4-ac79-225a79a3328c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8140781365796688, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5845737413475921, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "41ccd785-e72f-49fe-8791-f254aa1574ef", "name": "1b19f048-ac7a-4b40-bfe7-bc60a1426077", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "401ed287-96c4-47ad-bb6b-c09376d9100b"}}}]}, {"uuid": "8793d403-b23e-48cc-9bd9-4c73108709e0", "name": "load_p1rlv20465_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4759390d-43ec-45c9-9cca-320020dc1150"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "41ccd785-e72f-49fe-8791-f254aa1574ef"}}}}, {"uuid": "7fe82b55-5c16-40c9-b10e-5bc64c7fc02d", "name": "b5e45d5d-1bf7-4a54-a0d0-98e9e7e76ef7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8140781365796688, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5845737413475921, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f8024279-8d0b-4396-80aa-b0ebebd0bb90", "name": "18145921-4d73-4934-baed-7944f959f685", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7fe82b55-5c16-40c9-b10e-5bc64c7fc02d"}}}]}, {"uuid": "1ccceec8-8328-4dad-825d-786eb05ffcf0", "name": "load_p1rlv20465_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4759390d-43ec-45c9-9cca-320020dc1150"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f8024279-8d0b-4396-80aa-b0ebebd0bb90"}}}}, {"uuid": "ec91887c-9c4e-45fb-9283-1d9509dc8801", "name": "69b9e34b-1f8a-4670-bfba-5681e8c2ea10_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "565c66a1-9d75-4eb6-9103-dd216b5b89de", "name": "0d7f9147-a203-4140-96f3-5d6a51114635", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ec91887c-9c4e-45fb-9283-1d9509dc8801"}}}]}, {"uuid": "0d76342c-2396-4214-a4bf-f456d4521254", "name": "load_p1rlv20467_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58e2b774-ac04-435e-9e03-573b3aa94cfb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "565c66a1-9d75-4eb6-9103-dd216b5b89de"}}}}, {"uuid": "329fcd7f-6421-421b-a1e9-a0c9774a3398", "name": "c992e272-c468-4173-b205-553f230c7f23_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "83d890be-1de3-4c73-b7f3-4533594fb921", "name": "963b00b2-8d48-461e-aa6b-f857cca4ce80", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "329fcd7f-6421-421b-a1e9-a0c9774a3398"}}}]}, {"uuid": "8018e55d-e577-4e29-81d2-c6b758885388", "name": "load_p1rlv20467_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58e2b774-ac04-435e-9e03-573b3aa94cfb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "83d890be-1de3-4c73-b7f3-4533594fb921"}}}}, {"uuid": "7a1018dc-731c-4c84-8596-ccae7cce63bf", "name": "a66deca1-7605-4fe6-af3e-a2b629aaaf29_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9559171691321495, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6431a71d-fb58-4b2b-8728-b2f14b275221", "name": "99a19f84-1a9f-4e1c-8ba7-d9c94a2d0e14", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7a1018dc-731c-4c84-8596-ccae7cce63bf"}}}]}, {"uuid": "3d34d545-10cb-4ec2-844c-f8aa84b45fdb", "name": "load_p1rlv20469_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60fe0a16-aa4d-4fe8-9f39-81bfa13b505f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6431a71d-fb58-4b2b-8728-b2f14b275221"}}}}, {"uuid": "fc3a51b6-688a-4fe9-8c0f-4da7edd2e08e", "name": "ad5093ab-3779-47c2-834b-3b4c0e4ff47c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9559171691321495, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f374207e-cb43-4462-a20a-bc0597568d97", "name": "62de9be0-ce10-4551-ae7a-ecfc395afad7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fc3a51b6-688a-4fe9-8c0f-4da7edd2e08e"}}}]}, {"uuid": "7a2fe99a-ab27-4605-a90e-794c1864d276", "name": "load_p1rlv20469_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60fe0a16-aa4d-4fe8-9f39-81bfa13b505f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f374207e-cb43-4462-a20a-bc0597568d97"}}}}, {"uuid": "9652105b-26c8-43e1-86c9-fa3508510c4b", "name": "695f24d1-bcff-4c46-96de-e6e71d9e5aaf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.772705532239135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.33568286747913667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5091744d-12e4-4e1b-8838-937c50b63054", "name": "8675ddbe-5371-4ce2-a56e-5ec053964822", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9652105b-26c8-43e1-86c9-fa3508510c4b"}}}]}, {"uuid": "9745b2e8-cce1-42d7-bcb4-17d99d414e3e", "name": "load_p1rlv20473_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3eb214b9-827f-4995-a862-907be02b029d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5091744d-12e4-4e1b-8838-937c50b63054"}}}}, {"uuid": "be39e594-4f05-4bee-9b74-0fac136bb8ec", "name": "bc764a14-2cde-40d3-b6d5-84493c3f6efd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.772705532239135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.33568286747913667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d0a874a8-6ba0-4050-a7cc-c432c61f2415", "name": "15c7b000-6321-4bef-bfa7-4977989eaf80", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "be39e594-4f05-4bee-9b74-0fac136bb8ec"}}}]}, {"uuid": "52a31c24-3b82-4447-8912-06dbd691546d", "name": "load_p1rlv20473_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3eb214b9-827f-4995-a862-907be02b029d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d0a874a8-6ba0-4050-a7cc-c432c61f2415"}}}}, {"uuid": "1d21b064-5365-4048-872a-21abd9d21293", "name": "203c3bda-70e3-493b-b693-f5588be13c2f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "735cda5d-5016-48cd-aaa0-463cd519da98", "name": "157da864-e8b2-4903-b5ed-8c0fe72c4782", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1d21b064-5365-4048-872a-21abd9d21293"}}}]}, {"uuid": "80f467e5-7f90-44a6-8356-7cf7914e5f6d", "name": "load_p1rlv20478_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cd0effe0-d186-41a8-8197-24144fbc6218"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "735cda5d-5016-48cd-aaa0-463cd519da98"}}}}, {"uuid": "7709f9bd-c129-48d8-b9a6-eb8ed8f0e5f1", "name": "068ba0fc-60a4-41bf-bd57-90aea5217b06_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5fb3ed72-dd15-40c3-9fe4-84422b9d980e", "name": "dc761561-95d5-4345-a360-e22a514fd231", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7709f9bd-c129-48d8-b9a6-eb8ed8f0e5f1"}}}]}, {"uuid": "6c849935-fc6e-4c1e-9641-f6249caab38e", "name": "load_p1rlv20478_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cd0effe0-d186-41a8-8197-24144fbc6218"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5fb3ed72-dd15-40c3-9fe4-84422b9d980e"}}}}, {"uuid": "fd483ed2-68e3-445f-b375-06f936328d53", "name": "3d0dde73-4edb-4ff9-81ec-866af2313355_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4437884187508536, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6647073432497462, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "564d4ca5-373b-4f67-b677-422237e5ea0c", "name": "81315c28-c714-483b-af7d-e470c300d902", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fd483ed2-68e3-445f-b375-06f936328d53"}}}]}, {"uuid": "eade93de-ff75-4263-ab36-37f6392c70f8", "name": "load_p1rlv20480_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5d0a174-d49d-4c7e-a669-092f6408edf4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "564d4ca5-373b-4f67-b677-422237e5ea0c"}}}}, {"uuid": "1ce17efe-78d1-4851-ac9e-8ade9592e23b", "name": "bcf26ca4-bb62-446c-ba60-137cc3419286_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4437884187508536, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6647073432497462, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5d58b329-940f-499f-99e1-f5e6ebdd66d0", "name": "c2488af4-3aee-404f-9a2b-844cc1c7ef27", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1ce17efe-78d1-4851-ac9e-8ade9592e23b"}}}]}, {"uuid": "d89233ce-3b5c-40c2-8148-39cb020e8556", "name": "load_p1rlv20480_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5d0a174-d49d-4c7e-a669-092f6408edf4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5d58b329-940f-499f-99e1-f5e6ebdd66d0"}}}}, {"uuid": "39cdc73d-09f9-44e8-822c-9c513c93ff9e", "name": "565e2c77-bd5f-48f1-a5b6-232fd14fd774_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.109177669729331, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5486693289215298, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "66863d2d-5d48-44a0-996e-27f9e773740f", "name": "0cd7736a-ed87-4516-b385-4b23997e7ddd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "39cdc73d-09f9-44e8-822c-9c513c93ff9e"}}}]}, {"uuid": "3be81848-c16d-4e15-8043-56eab74dec44", "name": "load_p1rlv20492_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7af262b7-285c-4d06-b7ff-2f2a1971055a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "66863d2d-5d48-44a0-996e-27f9e773740f"}}}}, {"uuid": "3f800f84-d5ef-474a-be18-715755ebc8ca", "name": "cad3c948-664a-4ddd-a2ae-731cf726bb28_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.109177669729331, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5486693289215298, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f657e04d-89e2-439a-b2c5-dcdcbc637963", "name": "3c70cbae-4ecd-4f93-a71d-6ae728057831", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3f800f84-d5ef-474a-be18-715755ebc8ca"}}}]}, {"uuid": "cc77e7e8-e03c-4713-b2fa-215d3f2c2243", "name": "load_p1rlv20492_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7af262b7-285c-4d06-b7ff-2f2a1971055a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f657e04d-89e2-439a-b2c5-dcdcbc637963"}}}}, {"uuid": "39a51d11-5f0c-46c0-b4c7-2af2dd954ebc", "name": "81a41b58-eb9a-4539-a878-7dba2c28b143_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9444657359992037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.058006608995704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "37b07b41-077a-45c0-9324-13d6a7ba74d4", "name": "de4576f0-f6f8-4e80-8ef6-1773aa55e02e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "39a51d11-5f0c-46c0-b4c7-2af2dd954ebc"}}}]}, {"uuid": "2909b0c0-845f-4562-af72-2f9305e7abba", "name": "load_p1rlv20499_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af153ed-ed39-4433-ac12-19dfdb7b6bef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "37b07b41-077a-45c0-9324-13d6a7ba74d4"}}}}, {"uuid": "fb25be19-608e-41ef-9a56-cfd291dce449", "name": "a6005aed-4468-4377-9284-35ef79ff1428_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9444657359992037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.058006608995704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5ad5caa6-9a08-49c6-904c-a1a531c6ef73", "name": "2e525d33-9f5a-4a97-b599-023512e9421b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fb25be19-608e-41ef-9a56-cfd291dce449"}}}]}, {"uuid": "4a126325-c6b8-473a-a8f8-57f06397f106", "name": "load_p1rlv20499_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af153ed-ed39-4433-ac12-19dfdb7b6bef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5ad5caa6-9a08-49c6-904c-a1a531c6ef73"}}}}, {"uuid": "6d3471e3-3363-42fc-9259-5602fc27ed6c", "name": "1b7f7368-03e3-49c2-aca1-32a570bc7c83_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7956093485713416, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7629429667228578, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "373e538b-b9e4-4ca6-a1f2-6f2097d56b4b", "name": "b4accc81-346a-4c78-adb5-a3e46f18d6ca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6d3471e3-3363-42fc-9259-5602fc27ed6c"}}}]}, {"uuid": "46bb7b31-1c51-4577-a18f-e029061f6d23", "name": "load_p1rlv20502_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cacd3e49-55aa-4f05-bd7d-ae8aba0af87f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "373e538b-b9e4-4ca6-a1f2-6f2097d56b4b"}}}}, {"uuid": "8288e370-9098-494a-965c-85088e722ff3", "name": "05b0d269-5681-4ae5-888d-3811295a6736_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7956093485713416, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7629429667228578, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "141d6878-08dd-4335-838c-ad91b1d41622", "name": "a2055bd1-9ce8-4515-a48e-55eec6b1e260", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8288e370-9098-494a-965c-85088e722ff3"}}}]}, {"uuid": "d8f4b17f-af30-4202-a34d-50a18a3b0803", "name": "load_p1rlv20502_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cacd3e49-55aa-4f05-bd7d-ae8aba0af87f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "141d6878-08dd-4335-838c-ad91b1d41622"}}}}, {"uuid": "3359d395-ff77-4ea4-9c0c-99736773de9c", "name": "32c12bb3-5eca-41a1-99de-3f8946788258_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1419f1bb-43f7-42df-90f7-d852fab4f04f", "name": "a1ab948c-b0c8-467b-8e1d-009a593a9d49", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3359d395-ff77-4ea4-9c0c-99736773de9c"}}}]}, {"uuid": "f5b597dd-6be9-4387-86cd-b9353cfb2945", "name": "load_p1rlv20504_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b3e7495-7732-42ce-8d53-a5f1b7383ce4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1419f1bb-43f7-42df-90f7-d852fab4f04f"}}}}, {"uuid": "1b9c8237-cdcc-4788-8dc9-a2e38cae3cfd", "name": "9fc3d9d1-be67-42d0-b13b-fbe934a1f866_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10916cfb-46ea-418a-9fe5-97fc48b4b6ef", "name": "0f24b9ae-8dad-43d2-9345-f895af4434c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1b9c8237-cdcc-4788-8dc9-a2e38cae3cfd"}}}]}, {"uuid": "d4de4534-9b56-46f9-80ab-765f25e29ca7", "name": "load_p1rlv20504_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b3e7495-7732-42ce-8d53-a5f1b7383ce4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10916cfb-46ea-418a-9fe5-97fc48b4b6ef"}}}}, {"uuid": "c9eb1619-3c3d-4f08-8a82-c8c2946520b8", "name": "cbf50237-7e76-43f1-a222-375cca9e6ed2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4699462180170992, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3815978523472859, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9432afde-7c88-4d3e-868e-97f3205456a3", "name": "6d2fbc95-5243-4480-99fe-ceee1232380c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9eb1619-3c3d-4f08-8a82-c8c2946520b8"}}}]}, {"uuid": "b276dd5f-841c-4c7a-aa73-fbd5e223bf2f", "name": "load_p1rlv20509_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fe37b51-0258-4812-9d96-3cc28c4bd55b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9432afde-7c88-4d3e-868e-97f3205456a3"}}}}, {"uuid": "c8c20fa6-a023-4e8d-a933-7d2719c5465a", "name": "42b7aab2-d56b-4355-88df-e601c8f31bdb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4699462180170992, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3815978523472859, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e7ded97f-bbc4-4b6f-ae64-81781795ede1", "name": "c378b47a-4b56-42f7-8cc0-a1aeeffc51c8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c8c20fa6-a023-4e8d-a933-7d2719c5465a"}}}]}, {"uuid": "f4dfab8b-a25e-41f8-a9f4-e82697795162", "name": "load_p1rlv20509_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fe37b51-0258-4812-9d96-3cc28c4bd55b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e7ded97f-bbc4-4b6f-ae64-81781795ede1"}}}}, {"uuid": "9bf4e191-bba9-4688-86c3-11e2a3b1556c", "name": "486fa29e-1442-4521-b654-5df94e5acf1b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.996798907530164, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8717719006522443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "22e04164-803c-48f5-a56d-12cf40f867a1", "name": "d9db1151-69f7-4de1-9369-643383b87847", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9bf4e191-bba9-4688-86c3-11e2a3b1556c"}}}]}, {"uuid": "d09f7d54-3513-4a3b-bf4f-7fda658684de", "name": "load_p1rlv38126_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa4eed95-33b7-4827-8744-52d14149b386"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "22e04164-803c-48f5-a56d-12cf40f867a1"}}}}, {"uuid": "6736f48a-4c11-43b4-891f-9f29b71f0493", "name": "cd2cfbb2-88c7-4456-88bb-e68221dbd5bf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.996798907530164, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8717719006522443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ca6624d5-7866-48be-9078-6446a8a1c9d2", "name": "9a1029dd-92d1-4ec6-b1c5-2b26f4e507e6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6736f48a-4c11-43b4-891f-9f29b71f0493"}}}]}, {"uuid": "948ee14d-09ae-452c-9a1a-fe2b0b24d3d2", "name": "load_p1rlv38126_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa4eed95-33b7-4827-8744-52d14149b386"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ca6624d5-7866-48be-9078-6446a8a1c9d2"}}}}, {"uuid": "5a62a170-8408-4aee-ac89-b87283b59ca9", "name": "492571f6-4b8e-4149-8af4-782cf955b9e6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.771789007275423, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6748983225226206, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2bc2e514-fab8-4c9f-b7b8-411b8efda667", "name": "9501e8c1-8685-4967-a88e-abf0af5efe9d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5a62a170-8408-4aee-ac89-b87283b59ca9"}}}]}, {"uuid": "397cd87a-7d75-4f45-aa6f-52fe2df03ef8", "name": "load_p1rlv38269_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cbb9976-253c-4863-899f-9218c4496688"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2bc2e514-fab8-4c9f-b7b8-411b8efda667"}}}}, {"uuid": "5214f41f-f6cf-482d-a6ea-e38a09940a99", "name": "0a35ab40-62f0-409a-b114-8c09acffbd43_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.771789007275423, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6748983225226206, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5352644d-0db9-4d77-a7a8-6e0a66ca84b7", "name": "c2b502d9-0a08-4b93-9f2c-0c0ce6dd602b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5214f41f-f6cf-482d-a6ea-e38a09940a99"}}}]}, {"uuid": "fa091356-cbf4-4839-924a-1f6693e3ebbf", "name": "load_p1rlv38269_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cbb9976-253c-4863-899f-9218c4496688"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5352644d-0db9-4d77-a7a8-6e0a66ca84b7"}}}}, {"uuid": "64759ea8-ca8d-455d-ad79-a86f6f4c1078", "name": "2f2a96b2-f5cc-4111-9081-3f1c4b1fe5cd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.981510789736824, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31377757670385525, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "22684b35-2628-4241-8a5b-8bb62902e667", "name": "ddc680e4-e90e-4c70-9b8a-9d25ea26c9d4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "64759ea8-ca8d-455d-ad79-a86f6f4c1078"}}}]}, {"uuid": "02800fdd-973c-4ea6-947e-16920dc24b19", "name": "load_p1rlv51_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ccef6af-4bf6-44dc-b292-2bf9503a374a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "22684b35-2628-4241-8a5b-8bb62902e667"}}}}, {"uuid": "d369ec5a-9562-4ae3-9425-61193f466f3d", "name": "7255ae90-e0cc-4211-a37d-c7c594174568_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.981510789736824, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31377757670385525, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b3a1c1ea-ecc3-4918-9a3e-a9f251be8050", "name": "ce92b254-0249-4534-aa24-f59f9a14d49e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d369ec5a-9562-4ae3-9425-61193f466f3d"}}}]}, {"uuid": "b960c0ed-e728-42b5-ac3e-4f16188cf698", "name": "load_p1rlv51_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ccef6af-4bf6-44dc-b292-2bf9503a374a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b3a1c1ea-ecc3-4918-9a3e-a9f251be8050"}}}}, {"uuid": "61de8132-a291-4b6f-b49b-0b80c583fa54", "name": "13eef270-75e1-49cd-8450-61946b6a081a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5300176124233262, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6781680527999017, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d2143736-d7cb-4e9f-afd6-b762c6c77b83", "name": "96862f7e-44cc-4402-84fc-0a409a7fa1cf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "61de8132-a291-4b6f-b49b-0b80c583fa54"}}}]}, {"uuid": "dc46ae74-9f32-4dee-a22d-5d2f43234fac", "name": "load_p1rlv52_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fec0a162-4b0c-4577-b878-8dbc7c9935fc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d2143736-d7cb-4e9f-afd6-b762c6c77b83"}}}}, {"uuid": "51693030-21ed-433c-b940-8ddbee99ba4d", "name": "94e31f3c-0b45-4c7f-bb84-7f07ffa8a8c2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5300176124233262, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6781680527999017, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "851be08c-93cb-4463-b140-7ed120d378ce", "name": "72332b31-1f7b-4287-a60c-aedf13b24f80", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "51693030-21ed-433c-b940-8ddbee99ba4d"}}}]}, {"uuid": "81a65548-4893-4ebc-9d8f-1b53055dd9e2", "name": "load_p1rlv52_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fec0a162-4b0c-4577-b878-8dbc7c9935fc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "851be08c-93cb-4463-b140-7ed120d378ce"}}}}, {"uuid": "6abbf5df-fbd7-4a80-b490-df552d7a8b46", "name": "b47ca072-cfb7-4733-ad27-193f2f0bfe6b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6434260893942235, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2588956175598443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9e94ad99-4c13-4173-a92b-b7a2de0883ad", "name": "bce8dc23-2a13-447a-9cdb-1cd11f8da7d6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6abbf5df-fbd7-4a80-b490-df552d7a8b46"}}}]}, {"uuid": "fef89029-ffd0-4547-be17-2f8e25fd98c1", "name": "load_p1rlv53_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3c62646-6132-41ef-ba14-a06789885cd5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9e94ad99-4c13-4173-a92b-b7a2de0883ad"}}}}, {"uuid": "052c9588-be83-4b6d-b4e1-ce941bdc6797", "name": "6598428b-fe64-4bf0-b56b-cdda485c2999_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6434260893942235, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2588956175598443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7c9ba43e-b36b-4613-b5a1-25f468b059aa", "name": "d65071fc-6b69-4311-919e-214df90c62b4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "052c9588-be83-4b6d-b4e1-ce941bdc6797"}}}]}, {"uuid": "36946610-1dcc-4134-898b-141d86caebe6", "name": "load_p1rlv53_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3c62646-6132-41ef-ba14-a06789885cd5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7c9ba43e-b36b-4613-b5a1-25f468b059aa"}}}}, {"uuid": "cd4813cb-75e1-4fd1-995f-64aef6215ba9", "name": "9791f066-d559-48f2-8046-be65a4f4d83d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0716401691896973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6949594139700135, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "58b06842-060e-44f2-9f15-d2251967f3b2", "name": "c7e96f2d-342a-4a67-b4cc-f82c59ede79a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cd4813cb-75e1-4fd1-995f-64aef6215ba9"}}}]}, {"uuid": "56cd5e9f-8740-49f4-bb1e-5f4d8f19cfd7", "name": "load_p1rlv54_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20010301-32ce-4cc0-ab59-04ef3bcd35d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "58b06842-060e-44f2-9f15-d2251967f3b2"}}}}, {"uuid": "9c30dcb0-c947-4edc-accb-c0a02c230337", "name": "27a47eaa-eb7a-462e-9760-416f68e5ac5f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0716401691896973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6949594139700135, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6ec27cbf-3b73-4702-b082-dd7b3b1f2564", "name": "d40e052a-8972-4156-910d-04ea499fcc4e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9c30dcb0-c947-4edc-accb-c0a02c230337"}}}]}, {"uuid": "b6b82de1-3192-4c3e-9309-5d13723dfe0d", "name": "load_p1rlv54_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20010301-32ce-4cc0-ab59-04ef3bcd35d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6ec27cbf-3b73-4702-b082-dd7b3b1f2564"}}}}, {"uuid": "fa51dbf9-43bf-446a-9e23-9efce2fb5435", "name": "55e2003d-1b32-40de-8240-29a1f5add95d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3786182488338723, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5359363058124609, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "da3ee55b-aa13-409a-b48a-99c1ccbc9b50", "name": "ef778de1-7ba1-488d-b6e6-68ce6932d203", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fa51dbf9-43bf-446a-9e23-9efce2fb5435"}}}]}, {"uuid": "2f30ac26-a181-4f7c-8a9b-67ee9ead036d", "name": "load_p1rlv55_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36bdbc4e-edfa-425a-8e4c-e6123b567555"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "da3ee55b-aa13-409a-b48a-99c1ccbc9b50"}}}}, {"uuid": "312bc123-0043-4a03-a59d-87fdba87803e", "name": "03cfedd2-dd35-417e-97af-1239244ed228_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3786182488338723, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5359363058124609, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "273079c0-858a-4afc-842d-2db5866bcf6a", "name": "5f32ef60-0009-4b89-ab29-c49613ccf917", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "312bc123-0043-4a03-a59d-87fdba87803e"}}}]}, {"uuid": "487a0692-f420-4664-ba69-a3aaef52c74e", "name": "load_p1rlv55_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36bdbc4e-edfa-425a-8e4c-e6123b567555"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "273079c0-858a-4afc-842d-2db5866bcf6a"}}}}, {"uuid": "0b790946-d246-4c1b-b6d6-0067e4edf3e2", "name": "819ed8f1-a309-4e64-b58c-d80fd571d234_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b87f61d9-a337-4489-9654-b435a567edda", "name": "91ecacfa-eeb4-463b-a4b8-65ff42bbf590", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0b790946-d246-4c1b-b6d6-0067e4edf3e2"}}}]}, {"uuid": "a7ceae31-cc7f-49f5-a440-9c93041c8419", "name": "load_p1rlv56_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4694811a-ba43-4c78-b957-5209b1d961e2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b87f61d9-a337-4489-9654-b435a567edda"}}}}, {"uuid": "4997efb3-15ef-42ea-8a37-5a1d0d1aae2a", "name": "08d09627-4dd8-4c74-91ab-32d60227f297_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6f4634be-569c-45ec-a487-1965bfde5f15", "name": "83670ef5-637f-41d3-b84c-b45d9db70a0c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4997efb3-15ef-42ea-8a37-5a1d0d1aae2a"}}}]}, {"uuid": "070e0bec-c5d5-4935-a573-6a66c8208aff", "name": "load_p1rlv56_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4694811a-ba43-4c78-b957-5209b1d961e2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6f4634be-569c-45ec-a487-1965bfde5f15"}}}}, {"uuid": "ffa4dcab-7823-4f11-bf6a-11622e0b391d", "name": "82fe1b29-d541-46e7-b4b4-8e6e83de5da7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.511185229285174, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8722130080127372, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "31ac6afe-5d0b-494a-b26a-64cf8af68dc9", "name": "c4bda4a5-c91e-4fb1-b56f-ceac0da95f0a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ffa4dcab-7823-4f11-bf6a-11622e0b391d"}}}]}, {"uuid": "eca7e6a5-2e72-498f-98d6-4eca7a795e56", "name": "load_p1rlv57_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "925cb3b7-4ced-4a36-913f-e6851ed79b98"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "31ac6afe-5d0b-494a-b26a-64cf8af68dc9"}}}}, {"uuid": "8aa935a4-9605-4cb6-a05a-b8ebe51f985f", "name": "1126d6d6-6c31-495d-a583-9f93adb3930d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.511185229285174, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8722130080127372, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "804e20fc-ab81-4717-9429-66555387373a", "name": "8ee07f7d-15e5-4163-93f6-810e6c316b6f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8aa935a4-9605-4cb6-a05a-b8ebe51f985f"}}}]}, {"uuid": "1f3e6253-b8e5-4ab5-bdfd-46f9af4444d3", "name": "load_p1rlv57_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "925cb3b7-4ced-4a36-913f-e6851ed79b98"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "804e20fc-ab81-4717-9429-66555387373a"}}}}, {"uuid": "7bfa137b-d37c-442b-ae63-6721da62faca", "name": "3192da5c-462e-401a-ad0d-4ba86cbbac55_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "128dcbb1-a554-4a8c-a0ef-3f10fc6ece9a", "name": "6f48bd8b-c745-40a4-849d-120e366ef0a5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7bfa137b-d37c-442b-ae63-6721da62faca"}}}]}, {"uuid": "c6258ea2-4e94-495b-adcc-c27da8522fb8", "name": "load_p1rlv58_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a32ee184-f677-4333-b7ee-7bc30ab41467"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "128dcbb1-a554-4a8c-a0ef-3f10fc6ece9a"}}}}, {"uuid": "fbb74d60-d121-4c49-a358-66d3b15539f3", "name": "9777a21c-8520-4b8f-94ab-3a37c0672550_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b3f31c27-b8c8-496c-a1c1-6f526e6e4732", "name": "c6816637-b73c-498b-9c46-71c14dd403a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fbb74d60-d121-4c49-a358-66d3b15539f3"}}}]}, {"uuid": "96d1444f-c24b-41c0-89f4-083ac4adab31", "name": "load_p1rlv58_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a32ee184-f677-4333-b7ee-7bc30ab41467"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b3f31c27-b8c8-496c-a1c1-6f526e6e4732"}}}}, {"uuid": "e84d0660-066d-48bc-802c-5cbe6cac2b47", "name": "7ad86ff7-eac6-485e-9469-bb1107c41554_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8939358223380807, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6690937458929831, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "55fe9328-dfab-47ae-939b-f73d69f8ee61", "name": "5e2d0fd5-190f-4dca-90ea-7b395e67f368", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e84d0660-066d-48bc-802c-5cbe6cac2b47"}}}]}, {"uuid": "acf318a8-c7db-41ba-a49a-0d3705a9601e", "name": "load_p1rlv59_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b80bdb24-4bbf-4a57-bd5f-6a5ec9d484dd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "55fe9328-dfab-47ae-939b-f73d69f8ee61"}}}}, {"uuid": "07378ae1-451f-4351-85fa-e652d35d8dbd", "name": "3020cb8a-bacd-4e6c-b4dc-9d71e3b2a96f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8939358223380807, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6690937458929831, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4be7d08b-7d54-4074-9279-18ddfbf4b64d", "name": "944dac61-6bb8-4e25-b5b8-0ac042289404", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "07378ae1-451f-4351-85fa-e652d35d8dbd"}}}]}, {"uuid": "8156076c-aeb1-483e-8f62-90c96d0db843", "name": "load_p1rlv59_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b80bdb24-4bbf-4a57-bd5f-6a5ec9d484dd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4be7d08b-7d54-4074-9279-18ddfbf4b64d"}}}}, {"uuid": "9fd2f010-f617-43a1-90da-a2983bd347c4", "name": "899e1c08-546f-46cd-b858-30141d86191d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1603354468169496, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7593773040340845, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7ffe70a7-2162-4583-80f7-e23d5e9296ff", "name": "da86087f-0581-442c-ae58-fb5788a8094e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9fd2f010-f617-43a1-90da-a2983bd347c4"}}}]}, {"uuid": "40f63329-991b-4813-a3d9-3c0a33f74e01", "name": "load_p1rlv60_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7eb0d1e8-f85e-493e-b69b-26437fdb8ad9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7ffe70a7-2162-4583-80f7-e23d5e9296ff"}}}}, {"uuid": "dc057a50-c489-4f71-97d1-ad27dabaf0d4", "name": "feccd281-58a7-44c6-acad-281c415ca87d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1603354468169496, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7593773040340845, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d548187e-8179-4289-8ff0-3f449d1423ab", "name": "ffa07784-97a4-4bb1-aee9-d15a204eab67", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dc057a50-c489-4f71-97d1-ad27dabaf0d4"}}}]}, {"uuid": "59d7a530-4a41-4dca-a713-21c2102fdf1f", "name": "load_p1rlv60_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7eb0d1e8-f85e-493e-b69b-26437fdb8ad9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d548187e-8179-4289-8ff0-3f449d1423ab"}}}}, {"uuid": "ff35e51b-04ff-4f09-b482-99c27f5da1f3", "name": "f3126d12-75df-4d11-aa4a-a9c08cb9733f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9029063430901945, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8881818750925909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "329ffebf-7a8b-4470-ba34-ac91d74aa28b", "name": "2e847882-3c19-42d4-b0b9-2fdb6d848b33", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ff35e51b-04ff-4f09-b482-99c27f5da1f3"}}}]}, {"uuid": "c5b6c803-9bdd-4411-9f38-652d7968ea5a", "name": "load_p1rlv61_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d22bf2f5-74cc-47c7-ae3b-410fba27c113"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "329ffebf-7a8b-4470-ba34-ac91d74aa28b"}}}}, {"uuid": "8ce51ded-7745-44fc-9206-13f7b36d6891", "name": "3a2fdfa3-b04e-43f7-a3f9-18dc7f50dce9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9029063430901945, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8881818750925909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8210ad11-07f5-4373-9f5d-e77c22d9abef", "name": "c1260533-0133-42de-b91c-5b0f83659704", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ce51ded-7745-44fc-9206-13f7b36d6891"}}}]}, {"uuid": "578e25d2-3757-46ed-889a-360cc36ff3a2", "name": "load_p1rlv61_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d22bf2f5-74cc-47c7-ae3b-410fba27c113"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8210ad11-07f5-4373-9f5d-e77c22d9abef"}}}}, {"uuid": "3c87086a-2cd0-4d24-ab10-d38c58d4b720", "name": "76ddcb3d-8614-4e58-8f65-6f687775ca97_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4622944887503224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10483650830237357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5a347ad2-b6db-42a6-afdf-d1a8a92880b2", "name": "596a8497-bd49-420e-be09-72d24a3a98b7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3c87086a-2cd0-4d24-ab10-d38c58d4b720"}}}]}, {"uuid": "66875e4d-eb39-46ea-a39f-ee24343197db", "name": "load_p1rlv62_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "346dad85-3bf8-41a6-97ea-6b3b40a7f22e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5a347ad2-b6db-42a6-afdf-d1a8a92880b2"}}}}, {"uuid": "100071b2-0732-4f24-8a62-8be1cac1ccdf", "name": "6fdbc8d9-0d4c-4c6f-8661-8f6efc71b762_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4622944887503224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10483650830237357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "44334bee-647e-482e-b736-2ee9d2617deb", "name": "5338051a-88f9-4394-9b46-461b8ba3d191", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "100071b2-0732-4f24-8a62-8be1cac1ccdf"}}}]}, {"uuid": "04f417f8-f826-4bd9-b00e-01479da822d7", "name": "load_p1rlv62_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "346dad85-3bf8-41a6-97ea-6b3b40a7f22e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "44334bee-647e-482e-b736-2ee9d2617deb"}}}}, {"uuid": "8599c743-3264-4e27-b07b-8e70f18fc831", "name": "a4e57bc0-47f2-442e-916e-f28a36b42111_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7083181921938193, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5666922324635131, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "898bad6c-4120-423c-a19a-20da7d4feb01", "name": "5af4bc67-65a3-4da2-b651-b3acc3aef15f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8599c743-3264-4e27-b07b-8e70f18fc831"}}}]}, {"uuid": "78f2f1fb-da78-4ba9-9ad8-070d19f70556", "name": "load_p1rlv63_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8300f90c-9a3b-400d-af04-072125dce84f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "898bad6c-4120-423c-a19a-20da7d4feb01"}}}}, {"uuid": "01f9af62-6d2a-496a-bc8c-344e644cdf96", "name": "28c9d240-6539-4301-8c02-f9fdf480e77a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7083181921938193, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5666922324635131, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "86f365c8-5fb9-4b3e-b9de-50644f943c86", "name": "895b62dd-e0d9-407c-8610-7c3f92f4726a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "01f9af62-6d2a-496a-bc8c-344e644cdf96"}}}]}, {"uuid": "27a20244-06ca-45c4-9084-e1fcc1951a4c", "name": "load_p1rlv63_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8300f90c-9a3b-400d-af04-072125dce84f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "86f365c8-5fb9-4b3e-b9de-50644f943c86"}}}}, {"uuid": "b862f914-18e8-4f3f-a2ab-b4004b0a270c", "name": "c970302a-774f-49bf-b5e0-c2b30e2d230f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "07dab6b3-42a2-4c75-b6aa-e203b274546a", "name": "27d68dc6-3c92-412f-8cd5-96a426254f98", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b862f914-18e8-4f3f-a2ab-b4004b0a270c"}}}]}, {"uuid": "0ad073d3-f5f3-49ce-b085-f94653b6a7b8", "name": "load_p1rlv64_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5efd07ee-012a-40a4-97bb-07c1a5ed898c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "07dab6b3-42a2-4c75-b6aa-e203b274546a"}}}}, {"uuid": "3834f18a-3307-46e7-b128-2cb05ee29fdf", "name": "f42af146-ac7b-40bc-9d07-dc48db61df81_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "70b7f579-bc96-4d4f-8e5b-2676ad9989e2", "name": "35679726-0cd8-413c-9bb7-e7e069ee3ab3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3834f18a-3307-46e7-b128-2cb05ee29fdf"}}}]}, {"uuid": "62f41ebe-0ac1-445e-aa1c-f1b1ee6206c2", "name": "load_p1rlv64_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5efd07ee-012a-40a4-97bb-07c1a5ed898c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "70b7f579-bc96-4d4f-8e5b-2676ad9989e2"}}}}, {"uuid": "59222fb2-eed2-4531-886d-4ab391f26fd8", "name": "a4f53f0f-efda-4c30-9c32-c8d0501a6236_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.987999469244499, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42543082019456707, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aef24bb2-0143-4d23-b28f-76869b6f4d9d", "name": "def2e903-ba3c-4a94-a5f9-dc2fa49a6e46", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "59222fb2-eed2-4531-886d-4ab391f26fd8"}}}]}, {"uuid": "9efc84d7-f9d5-4795-8efd-d75517ccc450", "name": "load_p1rlv65_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e00fd9b-92b3-49c4-bcc2-957b9d2c7bad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aef24bb2-0143-4d23-b28f-76869b6f4d9d"}}}}, {"uuid": "ec001aa8-96b4-426f-ae24-a955358fb564", "name": "006c88d4-217f-4d52-b295-77ce7136abec_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.987999469244499, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42543082019456707, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5575b206-a4d9-4886-b943-6f83eb2da744", "name": "71eb4998-e8dc-46bd-983e-8f6ed559d229", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ec001aa8-96b4-426f-ae24-a955358fb564"}}}]}, {"uuid": "53fe26dd-75ad-46a7-ab2a-913f6a4efeb5", "name": "load_p1rlv65_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e00fd9b-92b3-49c4-bcc2-957b9d2c7bad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5575b206-a4d9-4886-b943-6f83eb2da744"}}}}, {"uuid": "afaef95b-19ae-4d4c-9bd7-29a86ae18b21", "name": "206317db-612b-4704-927f-fbf96927fc4e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4760012569901637, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5456626743322578, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "318e8349-3abc-4e20-b2d2-61184ad007af", "name": "12335a28-a671-4308-894b-a566e26d5169", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "afaef95b-19ae-4d4c-9bd7-29a86ae18b21"}}}]}, {"uuid": "601e7dc9-3f13-4d78-9de3-cac4d1420926", "name": "load_p1rlv66_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e90eb8a2-5db0-4861-96ef-a6991a0386eb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "318e8349-3abc-4e20-b2d2-61184ad007af"}}}}, {"uuid": "1ffcaa05-a532-4271-a582-0ef155917abf", "name": "98dda52b-a2a6-48d9-9ab8-0cb3f98c2c57_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4760012569901637, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5456626743322578, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c9ac0b1d-2a67-4235-b228-a001c83548de", "name": "51011efb-57db-45c9-b4c6-a38f0d590ca6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1ffcaa05-a532-4271-a582-0ef155917abf"}}}]}, {"uuid": "ca7d9648-ce04-409b-a2cb-3c41f2fd3466", "name": "load_p1rlv66_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e90eb8a2-5db0-4861-96ef-a6991a0386eb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c9ac0b1d-2a67-4235-b228-a001c83548de"}}}}, {"uuid": "01480de0-d6dc-4f77-b6fd-baec76795330", "name": "910685f4-8a79-4fb1-8e40-76a0dbc16746_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3018265224045242, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4135325648663858, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "48caeb22-cef1-44ce-8b7f-334baa96534a", "name": "deaf7d4c-d47c-456a-84d0-9426b6fa3647", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "01480de0-d6dc-4f77-b6fd-baec76795330"}}}]}, {"uuid": "56967678-ef97-4b84-8234-803c2743fc1d", "name": "load_p1rlv67_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64a67ed2-a563-4378-b6ac-d9a95339e862"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "48caeb22-cef1-44ce-8b7f-334baa96534a"}}}}, {"uuid": "b4172dd9-f9b8-41e5-99d2-3d6915d07d17", "name": "dc492572-240c-40df-9781-57f5e10675f7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3018265224045242, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4135325648663858, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0f4419de-9c75-4f53-8c77-250c21b8d5a6", "name": "22ea51f2-fbaa-46da-bb8e-d4317fbffd90", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b4172dd9-f9b8-41e5-99d2-3d6915d07d17"}}}]}, {"uuid": "fe5c82ba-f77a-4a58-b55b-703dbebd90a2", "name": "load_p1rlv67_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64a67ed2-a563-4378-b6ac-d9a95339e862"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0f4419de-9c75-4f53-8c77-250c21b8d5a6"}}}}, {"uuid": "7ada4d37-f4d3-40ed-9acd-d5faba481be4", "name": "e25d5b2a-2237-4c29-8fe4-17b6a3691be9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0137187800791063, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5284248988065299, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "543d61c1-6beb-4d3f-ad74-6ac05c55b839", "name": "585ee9d5-3a0b-4e15-af3a-7f3d401331c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7ada4d37-f4d3-40ed-9acd-d5faba481be4"}}}]}, {"uuid": "349f2751-aa29-4c04-984e-19e73fec0a3e", "name": "load_p1rlv68_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c22aa2c8-a6fc-4b27-a875-e07e3f50ecac"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "543d61c1-6beb-4d3f-ad74-6ac05c55b839"}}}}, {"uuid": "2b5d429b-3513-498e-95c9-5e9dcf8f77f7", "name": "13fb1350-2b2d-47f8-94b4-f87982450d96_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0137187800791063, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5284248988065299, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eacc52d2-bcce-4dcc-b6fa-08595047ae7b", "name": "246247a2-c496-41cf-88df-973e7f0884ee", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2b5d429b-3513-498e-95c9-5e9dcf8f77f7"}}}]}, {"uuid": "bc8c3905-1e5c-4811-9bfd-9689ad2d7792", "name": "load_p1rlv68_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c22aa2c8-a6fc-4b27-a875-e07e3f50ecac"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eacc52d2-bcce-4dcc-b6fa-08595047ae7b"}}}}, {"uuid": "fdb23bcf-6111-45ce-ba6c-9007569fce0e", "name": "3808ebb1-face-4a6e-ac7a-7c748c7b669e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7457942211533133, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8784341351558463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b97a3dfb-cc9f-4973-ba82-2213198cebe0", "name": "6768ceee-43be-427e-942b-0db671a29204", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fdb23bcf-6111-45ce-ba6c-9007569fce0e"}}}]}, {"uuid": "efaa2824-5c5f-4090-a1d0-e423cd416f50", "name": "load_p1rlv69_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "876ffb0b-f33c-45b2-a085-7b34103ecffc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b97a3dfb-cc9f-4973-ba82-2213198cebe0"}}}}, {"uuid": "4bc44e80-80e4-4ce6-ac5f-0c25e7ec3613", "name": "34f1e2e2-5b8c-4c0c-bff0-c252aa0692cb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7457942211533133, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8784341351558463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7c06383e-92cc-4e56-819a-5e3f04c47953", "name": "851c42dc-9eee-420a-b9f2-c2aaf0f5858d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4bc44e80-80e4-4ce6-ac5f-0c25e7ec3613"}}}]}, {"uuid": "4e205fd5-defb-40c6-9ee3-9503b82895d3", "name": "load_p1rlv69_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "876ffb0b-f33c-45b2-a085-7b34103ecffc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7c06383e-92cc-4e56-819a-5e3f04c47953"}}}}, {"uuid": "9318faf6-43f3-4b64-b795-832075723229", "name": "db559aeb-98cf-423d-a41a-7164ba97f874_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9024769844937937, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4778358547008617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eba25c14-7d83-4638-8dd7-0112ebd2975b", "name": "1b4e6b62-4c77-4826-a67a-a1f3ff117cd5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9318faf6-43f3-4b64-b795-832075723229"}}}]}, {"uuid": "b67279ba-f49e-43db-945d-e40605cabca3", "name": "load_p1rlv70_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e53e7714-06d1-4f85-89c5-f152629e8ab7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eba25c14-7d83-4638-8dd7-0112ebd2975b"}}}}, {"uuid": "051edfd9-73cd-4d9e-b201-66ecec1ba31a", "name": "23733246-02ee-4dbb-81e6-1328a944508e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9024769844937937, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4778358547008617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f696d473-ce5b-47cc-b65b-283c16067c2a", "name": "b6029e0d-b18c-45df-bae2-892a50823b72", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "051edfd9-73cd-4d9e-b201-66ecec1ba31a"}}}]}, {"uuid": "aa5c61af-18a1-453f-a3f4-a01a6ff35a85", "name": "load_p1rlv70_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e53e7714-06d1-4f85-89c5-f152629e8ab7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f696d473-ce5b-47cc-b65b-283c16067c2a"}}}}, {"uuid": "a5d6224c-b3d0-431d-9687-6aee701eed15", "name": "dcae4974-9e3e-475f-a5f0-c032a786fb75_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.67620786252276, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6753067705079763, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e8511645-a7d1-4737-8cc2-82d08e7818e6", "name": "437ee150-f220-427c-b24f-f817c64d804c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a5d6224c-b3d0-431d-9687-6aee701eed15"}}}]}, {"uuid": "753210c9-2537-407d-8134-f6994ae34c0f", "name": "load_p1rlv71_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d7791de-0cf6-4901-8b95-2d67870f09f5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e8511645-a7d1-4737-8cc2-82d08e7818e6"}}}}, {"uuid": "932477c7-093b-4a62-a26c-00c103b7afb4", "name": "c0c3200b-1955-40cd-a5ec-d8b3427fb9e7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.67620786252276, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6753067705079763, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1979701e-0c8f-4afd-82d1-72025b72e5b5", "name": "8fc03c47-5d22-4a89-ab4e-017f7f49625f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "932477c7-093b-4a62-a26c-00c103b7afb4"}}}]}, {"uuid": "f1e0849b-033d-4707-a5da-2f479ad9b242", "name": "load_p1rlv71_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d7791de-0cf6-4901-8b95-2d67870f09f5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1979701e-0c8f-4afd-82d1-72025b72e5b5"}}}}, {"uuid": "171f09a9-7d92-4ebd-bc33-a8ce323d7740", "name": "601db640-ac9c-4700-8e3d-ce9c23046380_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7083181921938193, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5666922324635131, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "64770796-9427-46e0-87b6-dba6df0d845f", "name": "0b8bba1b-3692-4a6b-9087-cacf89b0b8c6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "171f09a9-7d92-4ebd-bc33-a8ce323d7740"}}}]}, {"uuid": "73bd524a-2a7b-4850-9219-476e289e193a", "name": "load_p1rlv72_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc710fc3-ae5f-478e-997b-85467db7c93c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "64770796-9427-46e0-87b6-dba6df0d845f"}}}}, {"uuid": "18482ac3-1e93-4767-965b-b1551c7ec390", "name": "17d289a0-09c1-4ba9-8024-35bf760e95dd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7083181921938193, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5666922324635131, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e2005fa8-788f-49f4-a6fc-2a3fcb0789b1", "name": "30d7102e-5d90-496d-b7b2-5d74ecb4c561", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "18482ac3-1e93-4767-965b-b1551c7ec390"}}}]}, {"uuid": "2f4bbdec-435b-4b1c-b766-2dc3fd9d6b0b", "name": "load_p1rlv72_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc710fc3-ae5f-478e-997b-85467db7c93c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e2005fa8-788f-49f4-a6fc-2a3fcb0789b1"}}}}, {"uuid": "95a44352-4c4c-4538-a12b-b845882ef1b0", "name": "5dfa04b0-3d87-4fcf-89d3-d2d88f53864c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9051339071763382, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34139556761684264, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c1da838c-955a-49f5-96d2-5b319c046b1b", "name": "6cb71f3e-84ab-4eb1-8d64-e94b484e234f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "95a44352-4c4c-4538-a12b-b845882ef1b0"}}}]}, {"uuid": "72d6dc0d-dbd3-4ed7-99c7-a9079120b408", "name": "load_p1rlv73_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4e2991c-1404-44da-bbb5-5a2ebc43bde4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c1da838c-955a-49f5-96d2-5b319c046b1b"}}}}, {"uuid": "09f3f48f-ccec-44e7-945e-17e6b940dae3", "name": "637008f6-2fb8-4ce9-b3c3-4d5fdb03370d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9051339071763382, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34139556761684264, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8dad0dd4-67e1-45e0-8d3f-29b4204c8f7a", "name": "ba48f13c-9b3f-4f92-bf0f-c05e4b1713f8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "09f3f48f-ccec-44e7-945e-17e6b940dae3"}}}]}, {"uuid": "2c9f38cb-dd0e-47c2-8989-5b42a798d63b", "name": "load_p1rlv73_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4e2991c-1404-44da-bbb5-5a2ebc43bde4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8dad0dd4-67e1-45e0-8d3f-29b4204c8f7a"}}}}, {"uuid": "aced7483-5ca3-4fe3-9a80-7ad42326f6b3", "name": "eeff11e3-ccc5-4d5b-8432-d16b4d08dda8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.4509454152189125, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9978822313633423, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1066ce43-8f62-4734-b2f1-0d2d4e925c63", "name": "e1e3028b-662a-4460-aee6-532ec71815f3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aced7483-5ca3-4fe3-9a80-7ad42326f6b3"}}}]}, {"uuid": "79acc9d8-71a7-41c0-a471-9d9f27e2d3fc", "name": "load_p1rlv74_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5861410e-9d6d-423e-b967-2f2af65610b8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1066ce43-8f62-4734-b2f1-0d2d4e925c63"}}}}, {"uuid": "60451775-92b6-4bf4-9f2c-5448fe20d483", "name": "6d5fcafa-ab52-4b90-a0e2-edcb0734040a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.4509454152189125, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9978822313633423, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "343a81e9-b88c-4f56-8722-4252ebf06a78", "name": "07205db1-1d6a-4850-8bd6-bca3b295fa0e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "60451775-92b6-4bf4-9f2c-5448fe20d483"}}}]}, {"uuid": "dad038de-44f9-459a-bb66-d26063065fe2", "name": "load_p1rlv74_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5861410e-9d6d-423e-b967-2f2af65610b8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "343a81e9-b88c-4f56-8722-4252ebf06a78"}}}}, {"uuid": "e6727a08-79b7-4316-b1fb-92835a5f95c5", "name": "2ead64c7-e386-418d-8808-33609a3ceda3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6211116916449642, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3778136238343289, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8e88cc6c-66b8-49cf-a605-634760d875b6", "name": "d71f38b7-e1be-4217-bdd4-9bf759822e90", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e6727a08-79b7-4316-b1fb-92835a5f95c5"}}}]}, {"uuid": "bd3d2042-a713-4793-9d03-bf8942a59c48", "name": "load_p1rlv75_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ef51371-3fa2-400a-a2b4-3afa97ff2419"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8e88cc6c-66b8-49cf-a605-634760d875b6"}}}}, {"uuid": "7b61b33f-2010-4907-8271-5ff87054e074", "name": "1e148a6c-faa9-4a61-950f-6fd0b951acd4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6211116916449642, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3778136238343289, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "008bf0e6-0413-4467-8e83-1c8f960b4d47", "name": "99b717d0-dd73-4623-a3ab-281f3b99990e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b61b33f-2010-4907-8271-5ff87054e074"}}}]}, {"uuid": "cf336d44-81c4-4f45-81a3-dd94dada5711", "name": "load_p1rlv75_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ef51371-3fa2-400a-a2b4-3afa97ff2419"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "008bf0e6-0413-4467-8e83-1c8f960b4d47"}}}}, {"uuid": "401ab11c-c2ca-4af5-83c5-07c0363178e9", "name": "29ee0be8-831d-4de6-9384-3a20b0130b9b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9972586284721718, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5405993695804993, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8aa83d12-59f5-4bd1-9bab-eb86f3b8f9cd", "name": "49ad30de-c56a-46fa-b952-3da284311066", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "401ab11c-c2ca-4af5-83c5-07c0363178e9"}}}]}, {"uuid": "86acebf5-6adf-437e-bb88-4355e0a18752", "name": "load_p1rlv76_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3354497f-6de7-405d-9fca-a9c77463dc27"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8aa83d12-59f5-4bd1-9bab-eb86f3b8f9cd"}}}}, {"uuid": "a2bc55db-41cc-4697-9041-f6afcc88f075", "name": "5192ad56-41bf-4e17-ba69-df91196fded9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9972586284721718, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5405993695804993, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "212c4d7c-ce43-4ee7-99ea-d311eeb73f6b", "name": "46651f50-b9b3-4d1a-ab92-766edd5c0ea7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a2bc55db-41cc-4697-9041-f6afcc88f075"}}}]}, {"uuid": "829a24fa-03e0-4bb7-85bd-18af6a600c59", "name": "load_p1rlv76_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3354497f-6de7-405d-9fca-a9c77463dc27"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "212c4d7c-ce43-4ee7-99ea-d311eeb73f6b"}}}}, {"uuid": "907cd593-47d9-414c-9363-fc74d801bac8", "name": "5670f2ba-5ba8-4ff2-ac56-2b3074e6c8bc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5906266465914705, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5909884959248153, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "242af08d-0057-4a60-ad70-584db34fe2da", "name": "3bffc9ae-98d9-4564-a1d7-a2043f167347", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "907cd593-47d9-414c-9363-fc74d801bac8"}}}]}, {"uuid": "5b1e63c2-8a7f-49e8-81b4-33c812d96e66", "name": "load_p1rlv77_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f88a22a3-7e6c-4fc5-a8f4-a08cdaa3f5d6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "242af08d-0057-4a60-ad70-584db34fe2da"}}}}, {"uuid": "6c51c685-cd8d-428b-961a-6e577b49da69", "name": "c153e376-cd37-4afd-a4f0-44059fb3bd42_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5906266465914705, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5909884959248153, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f034abf0-9bf2-432b-9076-d81d579ab322", "name": "87ae233a-d756-446d-b7c6-f68f6b8809a8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c51c685-cd8d-428b-961a-6e577b49da69"}}}]}, {"uuid": "863be99e-0075-4534-ac07-5c38053fd75f", "name": "load_p1rlv77_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f88a22a3-7e6c-4fc5-a8f4-a08cdaa3f5d6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f034abf0-9bf2-432b-9076-d81d579ab322"}}}}, {"uuid": "e00ae0f3-c833-4c32-bc1b-62e2800b2ae3", "name": "54b10842-69f3-44d3-983a-1e05f6d6847e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.307297155025492, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20108954410245963, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "49074f23-3cec-4e91-8619-29b4df38c43f", "name": "954509de-44bf-4a2f-adb7-3266478e3ce0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e00ae0f3-c833-4c32-bc1b-62e2800b2ae3"}}}]}, {"uuid": "7ccb5eb7-4b8e-4d08-ba79-67b2d36c0e28", "name": "load_p1rlv78_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae76f058-b79a-4c0f-90be-f9cd7a02bcfc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "49074f23-3cec-4e91-8619-29b4df38c43f"}}}}, {"uuid": "513edbe7-9f8a-47e7-b306-d5ee792f8316", "name": "3fd72f79-30f1-4872-b8ce-b5bf993ace92_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.307297155025492, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20108954410245963, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "67d51062-6006-4e4b-870e-daf7b42dd301", "name": "25a078b4-10c4-4992-ab76-c8d1267af0e8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "513edbe7-9f8a-47e7-b306-d5ee792f8316"}}}]}, {"uuid": "01058f72-29ef-4ad0-ac3b-29577e185af8", "name": "load_p1rlv78_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae76f058-b79a-4c0f-90be-f9cd7a02bcfc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "67d51062-6006-4e4b-870e-daf7b42dd301"}}}}, {"uuid": "f6a96aff-44b9-4310-8cec-c6c2b14b33a8", "name": "b7379432-13b6-4763-a2ca-4bbfbad3f8fb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3315344999322854, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13574204648198762, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1d093d27-94a2-420f-9153-e4364aa561fe", "name": "bdb6170b-c44d-4582-8da9-2ce5e6b2894e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f6a96aff-44b9-4310-8cec-c6c2b14b33a8"}}}]}, {"uuid": "c2d61fb1-e7cb-4984-9dd4-61311694f5ff", "name": "load_p1rlv79_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4dd2283-6100-48ce-b4bc-0e37b7b4e409"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1d093d27-94a2-420f-9153-e4364aa561fe"}}}}, {"uuid": "7e58475c-002a-4f30-8c93-c7f602f794bf", "name": "af5fd900-aa6b-47ea-8c41-bcdfb62950b1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3315344999322854, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13574204648198762, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "678e4c04-ef44-4a06-ad06-ecd15fc903b3", "name": "45d74966-1781-49fc-9ee4-83e8c62a0e43", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7e58475c-002a-4f30-8c93-c7f602f794bf"}}}]}, {"uuid": "90b6d2ad-8447-41d3-8410-66bc45c0a8c4", "name": "load_p1rlv79_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4dd2283-6100-48ce-b4bc-0e37b7b4e409"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "678e4c04-ef44-4a06-ad06-ecd15fc903b3"}}}}, {"uuid": "8e73e272-ff08-4f45-ba2f-09fc3e5a8fa5", "name": "8c8ae855-b307-4833-a21c-c40bc511bc49_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.949137985829372, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.575540256876006, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6bea2e1f-72c3-4820-ab6e-e50a770156b9", "name": "289ae79d-4446-4fa2-afb5-8bda2d97054e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8e73e272-ff08-4f45-ba2f-09fc3e5a8fa5"}}}]}, {"uuid": "36240d9c-fa6e-4e7c-8806-54998ae16ba6", "name": "load_p1rlv80_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab7e1b4a-f8ec-4211-b7a0-d7f9057f576a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6bea2e1f-72c3-4820-ab6e-e50a770156b9"}}}}, {"uuid": "56d0a40d-1c01-4253-bd49-17a4ff33393f", "name": "6bde1f81-0fb4-4d6c-bcb2-37ff2712533a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.949137985829372, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.575540256876006, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8c2651f3-50f5-46e6-9e5f-1325b9300ce7", "name": "3a1244f7-b0f9-41df-9551-4a5222d91c23", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "56d0a40d-1c01-4253-bd49-17a4ff33393f"}}}]}, {"uuid": "9f53e5b8-cc13-4f88-8d06-dbf7d9f9250d", "name": "load_p1rlv80_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab7e1b4a-f8ec-4211-b7a0-d7f9057f576a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8c2651f3-50f5-46e6-9e5f-1325b9300ce7"}}}}, {"uuid": "dacbc3fd-e8fc-41e1-979a-f31318a804a7", "name": "1216a7da-abd7-4d65-893a-79470bfa76d5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.94390101914808, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4734308884348923, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "64d85114-19cb-4b9c-87b4-d99dd2964eb7", "name": "3aebcaa7-c27a-4c99-9dd4-d9ff99542bf0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dacbc3fd-e8fc-41e1-979a-f31318a804a7"}}}]}, {"uuid": "9b5ab49d-17fc-4a4b-824e-c2fd0dc8bc23", "name": "load_p1rlv81_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef92e40c-fe3c-4f7f-b844-884e1079e491"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "64d85114-19cb-4b9c-87b4-d99dd2964eb7"}}}}, {"uuid": "da745182-9985-4a61-8f4e-b5de2ad03235", "name": "46efe056-862e-4385-a344-c132c8299364_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.94390101914808, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4734308884348923, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ee387653-80e7-474e-846c-81b5f5b6a6d2", "name": "26c2ebf2-3c81-4891-8188-e08d41dd10a8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "da745182-9985-4a61-8f4e-b5de2ad03235"}}}]}, {"uuid": "f89298d2-b950-41d4-8276-101df4186a6e", "name": "load_p1rlv81_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef92e40c-fe3c-4f7f-b844-884e1079e491"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ee387653-80e7-474e-846c-81b5f5b6a6d2"}}}}, {"uuid": "af5a52a2-3fe9-4359-93fd-d55143549a28", "name": "1d6d2c06-1203-4968-ac98-b4d4ac8dc5b7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8534881847076217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.812795269620709, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "38eab04b-b674-49e4-bc32-07f6e0824eab", "name": "4e16fa12-982b-48ad-a47a-f250918d5af4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "af5a52a2-3fe9-4359-93fd-d55143549a28"}}}]}, {"uuid": "a62a54a5-6697-443b-a32b-361d4df7db89", "name": "load_p1rlv82_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3ddd704-2530-4392-8e9e-06e047b12f41"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "38eab04b-b674-49e4-bc32-07f6e0824eab"}}}}, {"uuid": "58a22351-641e-471f-8761-366370ea2434", "name": "c93e98c4-b94c-4d47-ae80-bd03cfe25cb2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8534881847076217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.812795269620709, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6fc40c4f-722e-4b46-a59a-49a12373a9cb", "name": "97c7b1a9-89fd-4b27-a3af-81893c03fdeb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58a22351-641e-471f-8761-366370ea2434"}}}]}, {"uuid": "8859a756-2afb-4ba2-b94c-856c2e66a892", "name": "load_p1rlv82_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3ddd704-2530-4392-8e9e-06e047b12f41"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6fc40c4f-722e-4b46-a59a-49a12373a9cb"}}}}, {"uuid": "6bd10507-5bba-4bd0-bef6-a72f290a6b67", "name": "6f2028c5-16e7-4328-8e03-13bf0033686e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.67620786252276, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6753067705079763, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b953ab0d-ba0c-4318-a252-6adef9567579", "name": "f4a2ebc7-287c-4c3b-a6f6-f3ce4a3586f1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6bd10507-5bba-4bd0-bef6-a72f290a6b67"}}}]}, {"uuid": "7665a9b0-76d2-400a-96c0-6f0990926a37", "name": "load_p1rlv83_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24c3e8d8-1520-4a05-84af-a70da6140b4d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b953ab0d-ba0c-4318-a252-6adef9567579"}}}}, {"uuid": "f70363eb-715d-40c7-a5fc-d7a56e04daf3", "name": "ef0c837c-6f9d-47a1-b498-882f08d091ce_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.67620786252276, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6753067705079763, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "78a15a68-4494-4c64-a4d8-7922e66e8997", "name": "f00b83e2-3f0d-4136-bbee-68ce5e3fc5c8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f70363eb-715d-40c7-a5fc-d7a56e04daf3"}}}]}, {"uuid": "88b75824-d49f-4113-a8c6-40ab676f6052", "name": "load_p1rlv83_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24c3e8d8-1520-4a05-84af-a70da6140b4d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "78a15a68-4494-4c64-a4d8-7922e66e8997"}}}}, {"uuid": "ad189afa-a8cc-4feb-aac9-4d99560096bb", "name": "e8272f62-d3e6-4e83-875d-129826f5a230_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2851011950034972, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5829386425893015, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "acd82457-1844-4bec-8ac5-5a37bf06e070", "name": "0374fa7b-d2bf-45ee-b82d-3ce35d0efd09", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ad189afa-a8cc-4feb-aac9-4d99560096bb"}}}]}, {"uuid": "051b254a-b970-418d-92f0-2373c3f21681", "name": "load_p1rlv84_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "55e7538f-4bde-4810-a237-ac0cad7ba805"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "acd82457-1844-4bec-8ac5-5a37bf06e070"}}}}, {"uuid": "1b337f5d-481e-47a9-94e2-6c18b30933c2", "name": "54310b84-29a0-4191-990c-fc85dcf39f15_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2851011950034972, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5829386425893015, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fb46c6ba-5700-4c6f-9aca-52a6c4a67e00", "name": "ad3546ac-85e1-4a6a-be55-77848057669d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1b337f5d-481e-47a9-94e2-6c18b30933c2"}}}]}, {"uuid": "11d28132-44eb-4000-b730-9f6b60fb5574", "name": "load_p1rlv84_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "55e7538f-4bde-4810-a237-ac0cad7ba805"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fb46c6ba-5700-4c6f-9aca-52a6c4a67e00"}}}}, {"uuid": "8ea51f72-6007-45f2-934c-ee720a2a2a6d", "name": "e93d34db-209b-410b-99e8-74e2a10f1f24_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.904546554088597, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7711735109904765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ccf23164-9fe3-498a-8339-0cd4afaaac3b", "name": "34eb3b6c-c8a2-40b9-b54c-561072b6b44d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ea51f72-6007-45f2-934c-ee720a2a2a6d"}}}]}, {"uuid": "23d33e7c-c398-44ea-9d3b-24dfc98d40c8", "name": "load_p1rlv85_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcc52dd9-bacb-4e49-a057-d3747f89a7f7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ccf23164-9fe3-498a-8339-0cd4afaaac3b"}}}}, {"uuid": "55918753-a6a5-4ae9-a332-7fe46c0295e7", "name": "d5657e75-94e2-4bd5-9b06-70f7046f60c4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.904546554088597, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7711735109904765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7069ce04-1c39-41c2-be08-6a3ca23bbda5", "name": "a581fb52-0345-443c-8a00-55901ea16962", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "55918753-a6a5-4ae9-a332-7fe46c0295e7"}}}]}, {"uuid": "c4dba301-7f1a-4f27-a876-cf8834058be0", "name": "load_p1rlv85_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcc52dd9-bacb-4e49-a057-d3747f89a7f7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7069ce04-1c39-41c2-be08-6a3ca23bbda5"}}}}, {"uuid": "35c623f4-72bb-454f-917f-134d2d188e73", "name": "b7492d0b-7810-4e67-b9ff-6ba1915425df_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8309189378455104, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6069744647018672, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c1b59f56-d91c-4edc-bdb4-5b6d88df2d73", "name": "17d3e626-6bd6-420f-b575-cfec57187186", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "35c623f4-72bb-454f-917f-134d2d188e73"}}}]}, {"uuid": "78febb96-7b66-4d6e-941a-633a0723f10e", "name": "load_p1rlv86_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "540e0121-fc39-4c2c-9fbc-012c020f5994"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c1b59f56-d91c-4edc-bdb4-5b6d88df2d73"}}}}, {"uuid": "cb5d3869-1d7a-4b61-85bd-8d1a5aa2b9dd", "name": "93bb007f-267b-4671-9657-383b7126fe63_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8309189378455104, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6069744647018672, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e4bbaed5-dcd9-4e1e-868b-1af88726dd4e", "name": "175acd64-2275-44e6-bd26-30a79b5a1ec6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cb5d3869-1d7a-4b61-85bd-8d1a5aa2b9dd"}}}]}, {"uuid": "9b25e5dd-b353-4e2b-bdd0-8b2f40cc299b", "name": "load_p1rlv86_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "540e0121-fc39-4c2c-9fbc-012c020f5994"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e4bbaed5-dcd9-4e1e-868b-1af88726dd4e"}}}}, {"uuid": "f8606531-663e-47cf-8178-789276058169", "name": "6ab123dc-6c35-4df5-8209-24b8745916dd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6155541211188646, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3901757582026717, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7c78dccd-a904-40f6-aae0-535fd349386c", "name": "d096316e-5678-4fdc-96ea-49e7e048da3b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8606531-663e-47cf-8178-789276058169"}}}]}, {"uuid": "20f2b601-a6da-407d-9ddf-87c50e403dec", "name": "load_p1rlv87_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "46ee0e6c-daf7-4412-94a7-5332a6a97656"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7c78dccd-a904-40f6-aae0-535fd349386c"}}}}, {"uuid": "9b3e1397-1275-46d9-9b9a-44746c91dd20", "name": "258bad8c-9602-4318-9c3c-e2a3e4e2e011_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6155541211188646, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3901757582026717, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3b78c1ee-1cbb-4069-aec6-ee865c5810cf", "name": "fc6c0202-3e9d-4df9-840e-d229a3b85917", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9b3e1397-1275-46d9-9b9a-44746c91dd20"}}}]}, {"uuid": "3be5a22a-d467-4a98-a15c-ee8144f64ffa", "name": "load_p1rlv87_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "46ee0e6c-daf7-4412-94a7-5332a6a97656"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3b78c1ee-1cbb-4069-aec6-ee865c5810cf"}}}}, {"uuid": "98718c72-49ed-4f8b-94f4-4486786a2f17", "name": "8d2cd1f7-4c5f-4548-8f39-8c21701f2f80_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3439175585507637, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8866404836608991, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a834a5c7-98fd-4c36-a1a2-117df752ee7d", "name": "66056a6c-7515-44a0-8fe2-220d35df50b5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "98718c72-49ed-4f8b-94f4-4486786a2f17"}}}]}, {"uuid": "31a2910b-97f0-435f-8446-edb59ff49f20", "name": "load_p1rlv88_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "188047cd-3f14-4240-91fe-30113d48152b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a834a5c7-98fd-4c36-a1a2-117df752ee7d"}}}}, {"uuid": "2205e2f6-a33f-480b-871b-dff81b6dfe6f", "name": "74a63789-fa7d-45df-9e5f-00cf98af8d57_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3439175585507637, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8866404836608991, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "811f21d5-64e0-4d1f-aa87-f48fe0c030be", "name": "22c86dd0-3ef8-43a5-a22d-be5e7a8838b3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2205e2f6-a33f-480b-871b-dff81b6dfe6f"}}}]}, {"uuid": "13edc7c2-1815-4ec8-864b-37a1be4f09ed", "name": "load_p1rlv88_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "188047cd-3f14-4240-91fe-30113d48152b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "811f21d5-64e0-4d1f-aa87-f48fe0c030be"}}}}, {"uuid": "58590f5d-13ba-4b38-bd02-39cb9b23f78c", "name": "e9546252-1b58-4899-9c11-7318389954bc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.872515319591797, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7328111219910317, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "84b98861-33f5-4f04-a307-ce744f52b0a2", "name": "324e5a11-5970-42e7-b780-a2a7a153e909", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58590f5d-13ba-4b38-bd02-39cb9b23f78c"}}}]}, {"uuid": "9df16e4f-d791-4919-8ac9-6fa71869a7f6", "name": "load_p1rlv89_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24d75e9a-0249-48ca-ad10-32738bb6a519"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "84b98861-33f5-4f04-a307-ce744f52b0a2"}}}}, {"uuid": "4411040a-b8aa-4292-8c6f-6b01cd8a0937", "name": "0215f688-785c-42bb-9301-214b3f14d55b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.872515319591797, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7328111219910317, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d71ed8bc-50f6-4a34-bd20-821b33cb7331", "name": "d6b371e7-a88d-4ac8-90bc-da731158d936", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4411040a-b8aa-4292-8c6f-6b01cd8a0937"}}}]}, {"uuid": "68f4c66d-4cd7-49d8-bf03-0e936b39cc47", "name": "load_p1rlv89_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24d75e9a-0249-48ca-ad10-32738bb6a519"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d71ed8bc-50f6-4a34-bd20-821b33cb7331"}}}}, {"uuid": "f0818f91-427a-4dac-859a-9db5b784179b", "name": "606a83fe-20ef-45bd-92c5-f5146a296b44_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6767459289154356, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5300288174067083, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4e5f0c53-8b54-448d-a458-e7d628e7e647", "name": "7d1c415d-e8dc-4012-ba79-b478fef95e10", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f0818f91-427a-4dac-859a-9db5b784179b"}}}]}, {"uuid": "2938636d-de76-44c7-8bae-5ca12ea547e5", "name": "load_p1rlv90_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e06b2ac7-926e-4caf-afac-386910d4ea5e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4e5f0c53-8b54-448d-a458-e7d628e7e647"}}}}, {"uuid": "737e66f7-4b97-4feb-9812-0697f1b837ea", "name": "98a76c71-fc18-4ba7-aaae-ffd2f60dbabf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6767459289154356, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5300288174067083, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "383a78a2-9fcc-402b-a8c8-d9401b3d9bc1", "name": "5bdef5f2-0868-4b5e-8d9b-45781ef23db4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "737e66f7-4b97-4feb-9812-0697f1b837ea"}}}]}, {"uuid": "4e1fefc7-4df0-49fd-9047-d74b8256fd10", "name": "load_p1rlv90_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e06b2ac7-926e-4caf-afac-386910d4ea5e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "383a78a2-9fcc-402b-a8c8-d9401b3d9bc1"}}}}, {"uuid": "18090cd0-1050-4ea4-9081-1b5987f13ed5", "name": "859d3065-e984-44a5-80da-e2ac323cea76_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.089287670026504, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22715368737478026, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dd1b2f42-bfb0-4733-be1f-244a6f9aff0f", "name": "904dc742-32db-4a73-a9b3-ec2156ab46bf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "18090cd0-1050-4ea4-9081-1b5987f13ed5"}}}]}, {"uuid": "99780ee0-abf9-4307-b4e4-ed14d98ebf73", "name": "load_p1rlv91_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a1f01bc-d1f1-4d92-b1e2-1f8223624c52"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dd1b2f42-bfb0-4733-be1f-244a6f9aff0f"}}}}, {"uuid": "fb746a89-e5d8-407e-983a-f03e98d40634", "name": "b0033884-40dc-422f-a2ca-e44dfe1edc9f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.089287670026504, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22715368737478026, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "29c942c6-c2bb-4192-9690-6d377bdf7fa1", "name": "43d21665-1ce2-4376-aa4a-c9603e1290cd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fb746a89-e5d8-407e-983a-f03e98d40634"}}}]}, {"uuid": "9f5996d0-70d0-46af-a97f-981b46824f37", "name": "load_p1rlv91_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a1f01bc-d1f1-4d92-b1e2-1f8223624c52"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "29c942c6-c2bb-4192-9690-6d377bdf7fa1"}}}}, {"uuid": "fe1ba8b5-2e95-43ff-a991-580ba9a4d8e8", "name": "6159d973-f677-4323-8366-eed9b570ef52_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.298373512871933, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.08780226018253445, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6ddbae49-7bba-48e9-b129-7c86cceadc16", "name": "4afa950b-0abb-4e3f-8041-4d9ee05e086c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fe1ba8b5-2e95-43ff-a991-580ba9a4d8e8"}}}]}, {"uuid": "6e7fa03a-2160-4bc3-9a4f-cc003402162c", "name": "load_p1rlv92_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db8f484a-94d5-4d20-8ebf-6708b1601a0d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6ddbae49-7bba-48e9-b129-7c86cceadc16"}}}}, {"uuid": "f8b727ed-1984-40fc-9771-1efd1d55309f", "name": "bd82d5a0-503b-4b3c-b694-64730b273252_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.298373512871933, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.08780226018253445, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5bd4562a-8138-450e-a625-2848c9a1501a", "name": "75349981-2801-4269-9d4f-7e93fd11a841", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8b727ed-1984-40fc-9771-1efd1d55309f"}}}]}, {"uuid": "614d03f1-10f5-420d-b6f1-ae9627c6077f", "name": "load_p1rlv92_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db8f484a-94d5-4d20-8ebf-6708b1601a0d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5bd4562a-8138-450e-a625-2848c9a1501a"}}}}, {"uuid": "acc5f822-9896-4ed6-b7f9-961c04a79fcf", "name": "2d5e9b56-2043-4d51-b09f-0eae337cba7c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1206689642843692, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34257205075767067, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a5557f1-421f-4b7b-928f-124c33d795b9", "name": "3c2684f6-00a4-4532-85da-7a965986254c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "acc5f822-9896-4ed6-b7f9-961c04a79fcf"}}}]}, {"uuid": "c54cefdf-63d6-4bcf-bfae-bcfa3a804ce2", "name": "load_p1rlv93_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0060c029-188f-4725-a935-8d0d9cc892f7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a5557f1-421f-4b7b-928f-124c33d795b9"}}}}, {"uuid": "c677df67-d23d-4c53-a4ad-da31ba873674", "name": "f61f8ad5-a993-4e20-be49-6f3094aae04a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1206689642843692, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34257205075767067, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ae9693df-240a-4ac1-ac44-1fa9ec0c4ac9", "name": "e82986f7-3cd6-4361-b8cd-9dcceedd0c16", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c677df67-d23d-4c53-a4ad-da31ba873674"}}}]}, {"uuid": "cba07de9-9ed8-4aaf-915f-356b567f28e9", "name": "load_p1rlv93_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0060c029-188f-4725-a935-8d0d9cc892f7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ae9693df-240a-4ac1-ac44-1fa9ec0c4ac9"}}}}, {"uuid": "f5710e93-0e63-4dda-8322-b339e9baffcc", "name": "a60b88aa-9ce2-438b-acfd-d3a51a091e64_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.365256087534968, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9406994095530364, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d3515b45-b2cd-4e6d-82dc-9d0d1fcf1ff6", "name": "90eba57b-5b28-40a8-8df5-43435c8b0322", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f5710e93-0e63-4dda-8322-b339e9baffcc"}}}]}, {"uuid": "81751aa3-7248-4487-bbb0-b75319417ef3", "name": "load_p1rlv94_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db2d4080-1f43-47a3-9f3a-e25d1e4f5076"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d3515b45-b2cd-4e6d-82dc-9d0d1fcf1ff6"}}}}, {"uuid": "2bcf0af3-f731-4831-b95e-ab9b2c537f24", "name": "4511a972-ce32-4d4c-9040-93b763ddb4f0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.365256087534968, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9406994095530364, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6746918e-c2fb-499a-a5de-c0c2e352830c", "name": "dacd287d-7ee9-4588-a9d7-cc997c4f5b54", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2bcf0af3-f731-4831-b95e-ab9b2c537f24"}}}]}, {"uuid": "3da52a7f-22d5-4c46-9943-4acb1cf2e86d", "name": "load_p1rlv94_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db2d4080-1f43-47a3-9f3a-e25d1e4f5076"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6746918e-c2fb-499a-a5de-c0c2e352830c"}}}}, {"uuid": "9da11bbe-1bb9-4cbe-aaea-cba496a39b01", "name": "7b735d2a-834d-4e2a-bdd2-b01ed3d8ad3d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2874196130666418, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9219654181970236, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "99b4f378-964b-4383-ad8c-0846925d399a", "name": "0c9ff4eb-c022-4e78-8ab2-7bb6a0a5d5b5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9da11bbe-1bb9-4cbe-aaea-cba496a39b01"}}}]}, {"uuid": "7403fe65-1672-4aa6-bd34-9eec32802b07", "name": "load_p1rlv96_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31508077-f731-47cb-94a9-869d7910e406"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "99b4f378-964b-4383-ad8c-0846925d399a"}}}}, {"uuid": "d2b635de-b7b8-4569-9d7e-06f777a219b5", "name": "4a173121-e8c8-4e35-b054-6f8ceb91a0ae_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2874196130666418, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9219654181970236, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e36bcef7-5406-4902-b65c-0dccf635ba6c", "name": "e39255b9-2c3d-4945-acad-e7ab0a898bea", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d2b635de-b7b8-4569-9d7e-06f777a219b5"}}}]}, {"uuid": "07546d73-cdde-49cf-9284-ed9c72056d08", "name": "load_p1rlv96_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31508077-f731-47cb-94a9-869d7910e406"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e36bcef7-5406-4902-b65c-0dccf635ba6c"}}}}, {"uuid": "c16641aa-8d69-474e-83f8-c5385964d545", "name": "04e55605-b003-4b7c-9d1e-ca79dd286853_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.297832728168154, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6109723215697453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c423ba8b-348a-4c26-81c6-ccd5725736f5", "name": "eaeca3f8-e3de-487d-8694-519965bca661", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c16641aa-8d69-474e-83f8-c5385964d545"}}}]}, {"uuid": "ff0f1762-f691-4ce5-ab27-622a05e5025f", "name": "load_p1rlv98_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "82f19d5c-0941-411d-8baa-3ba029471dae"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c423ba8b-348a-4c26-81c6-ccd5725736f5"}}}}, {"uuid": "bf1c9d20-3c94-45dd-b6cd-2ce537df9f0a", "name": "671e29c0-a4f8-4e6f-8a68-960733b787f0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.297832728168154, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6109723215697453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bc14a11d-391f-4b84-8e60-875d7f8679d5", "name": "9fb52573-f6d7-4fcf-925f-e50b3885a9c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bf1c9d20-3c94-45dd-b6cd-2ce537df9f0a"}}}]}, {"uuid": "7905d68d-503b-472c-967a-7778a52f0994", "name": "load_p1rlv98_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "82f19d5c-0941-411d-8baa-3ba029471dae"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bc14a11d-391f-4b84-8e60-875d7f8679d5"}}}}, {"uuid": "7e69ce24-4795-4dbb-b16c-ef9fa0af989d", "name": "6117d5a6-e73f-4b72-89d1-9c9623c39420_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5294251690866196, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6012221542672356, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c78366f5-22c9-4231-a55e-c5b776304b75", "name": "8c7efc8e-047f-4943-afc9-6ddbb1c58202", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7e69ce24-4795-4dbb-b16c-ef9fa0af989d"}}}]}, {"uuid": "e8df70c9-8f8f-4739-abab-34b80d2a23b0", "name": "load_p1rlv99_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc4a448a-c6cb-4714-b8e6-b75bc6bc219c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c78366f5-22c9-4231-a55e-c5b776304b75"}}}}, {"uuid": "c56ce2ea-ddf1-4f61-bb61-b570626f985a", "name": "202db26d-789c-46af-9ccb-e957aec15c92_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5294251690866196, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6012221542672356, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e5fa98dd-17e0-4883-a85e-6066e6729a98", "name": "fdfadd89-1aab-4f45-9ca4-33d1a298628e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c56ce2ea-ddf1-4f61-bb61-b570626f985a"}}}]}, {"uuid": "cd4a408f-1a33-428f-8101-bed597fcb8c3", "name": "load_p1rlv99_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc4a448a-c6cb-4714-b8e6-b75bc6bc219c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e5fa98dd-17e0-4883-a85e-6066e6729a98"}}}}, {"uuid": "184da65b-8dc6-4ca7-8329-4e9be7d55810", "name": "e1145f98-92e2-4c52-a121-c70a893fee4f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.779437116944347, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0510023138100544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "abf9b856-24e3-43b0-993e-941a700e5987", "name": "c4030a1e-6309-4395-954e-04d3068913d1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "184da65b-8dc6-4ca7-8329-4e9be7d55810"}}}]}, {"uuid": "f15e6046-885a-43de-bd29-9aab72b45f9a", "name": "load_p1rlv100_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62a0d673-eaba-4032-9038-8095e2d53999"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "abf9b856-24e3-43b0-993e-941a700e5987"}}}}, {"uuid": "cfd38289-4519-4c78-9e88-aa9280b90980", "name": "75c824d7-7ace-4c79-ad40-933f5f7e2c5e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.779437116944347, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0510023138100544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "04280e76-fa83-4fed-9f67-b16b1e5b6b49", "name": "3a94513d-40ef-46e5-b7ea-92d4868cf199", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cfd38289-4519-4c78-9e88-aa9280b90980"}}}]}, {"uuid": "215191e3-9ef4-4b21-b313-d2806787197c", "name": "load_p1rlv100_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62a0d673-eaba-4032-9038-8095e2d53999"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "04280e76-fa83-4fed-9f67-b16b1e5b6b49"}}}}, {"uuid": "5b4e2d80-8248-4202-a3e8-45a7ae4710f9", "name": "8247a08c-fdb0-411b-8148-73efe847f6ce_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.684904254134122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42635901069761617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "041fd195-9980-4855-8874-8c010832cf81", "name": "0f69f44e-235d-4ce5-9212-23afb844695f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b4e2d80-8248-4202-a3e8-45a7ae4710f9"}}}]}, {"uuid": "3ee2b65f-9dd7-4934-8212-cd6ef1a27825", "name": "load_p1rlv101_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48d1be49-5aca-4e18-8b85-2a1274b3f26d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "041fd195-9980-4855-8874-8c010832cf81"}}}}, {"uuid": "06baf80c-e581-4a2d-8094-32f6084c37d2", "name": "28e8fd55-991f-4d03-a67c-f331858403d8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.684904254134122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42635901069761617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bf9a217b-e25f-4108-8a18-7d0780f3baab", "name": "e6385cf4-58b6-4786-a1b8-c7b9f35d2275", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "06baf80c-e581-4a2d-8094-32f6084c37d2"}}}]}, {"uuid": "9824b145-a3bb-4887-bf47-ca9d0d0e83ed", "name": "load_p1rlv101_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48d1be49-5aca-4e18-8b85-2a1274b3f26d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bf9a217b-e25f-4108-8a18-7d0780f3baab"}}}}, {"uuid": "235cb1eb-79de-4ad0-8c13-d63c4b99b76d", "name": "deb4cd16-3566-4648-9436-d95d86e4dbd4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3841896439528762, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.62886585412856, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8621e40e-4298-42dc-804a-4591b2e0be9c", "name": "4ab2e48e-e6e1-4262-8492-5932347eb446", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "235cb1eb-79de-4ad0-8c13-d63c4b99b76d"}}}]}, {"uuid": "ae29ac6d-f514-4368-abfe-21c408a60c50", "name": "load_p1rlv102_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06a432e3-dd37-4c52-b954-6652bb529c8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8621e40e-4298-42dc-804a-4591b2e0be9c"}}}}, {"uuid": "1d62996a-acb8-4e7a-a168-70dff02adce8", "name": "eeed8d1d-bef3-4c78-a573-cfe779410549_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3841896439528762, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.62886585412856, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ab2839d8-b9ee-435e-bddd-23a2cc6eb79b", "name": "cda44325-54f8-43ee-ba3b-8a801e25efc0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1d62996a-acb8-4e7a-a168-70dff02adce8"}}}]}, {"uuid": "328b551e-2c99-47e8-94d6-1e6d8062cb39", "name": "load_p1rlv102_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06a432e3-dd37-4c52-b954-6652bb529c8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ab2839d8-b9ee-435e-bddd-23a2cc6eb79b"}}}}, {"uuid": "148e865f-b291-44ae-b89a-29810ad5eaa7", "name": "967f2b60-182a-4b89-968b-14af128f040a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2440101223346245, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10648703060010346, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b829b28a-b328-4762-aca6-6fa9fe5838a9", "name": "b40fd67d-119e-4af8-a80c-6f4c065633f9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "148e865f-b291-44ae-b89a-29810ad5eaa7"}}}]}, {"uuid": "fdd5293f-73d1-4c96-8bfc-9c3a25fc0331", "name": "load_p1rlv103_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85afc796-3fe5-4027-b84e-10d502124636"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b829b28a-b328-4762-aca6-6fa9fe5838a9"}}}}, {"uuid": "b0bedc38-f5ec-4329-986f-8320ea45375f", "name": "0640dbbc-4f29-42ba-a44f-a9bafca5c79b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2440101223346245, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10648703060010346, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "368d54dd-4d93-4beb-8956-ab1d59f80508", "name": "b93ea6cb-86f8-4177-be13-5264cefa5c3e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b0bedc38-f5ec-4329-986f-8320ea45375f"}}}]}, {"uuid": "e8f19935-fdb6-422c-a4ea-650290277367", "name": "load_p1rlv103_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85afc796-3fe5-4027-b84e-10d502124636"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "368d54dd-4d93-4beb-8956-ab1d59f80508"}}}}, {"uuid": "aea1ad96-2ffc-46ed-b4b6-62581ccf1126", "name": "2843f780-0c39-4f88-9e82-8a49607d6a80_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.651721747239447, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.750976002130125, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ba45d071-0691-4fb5-a0fa-d9fbb2f0a8f1", "name": "7344c816-a488-4607-869f-eca427b482d9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aea1ad96-2ffc-46ed-b4b6-62581ccf1126"}}}]}, {"uuid": "0f430a54-77f8-46b6-bbc2-0a0f6f19955f", "name": "load_p1rlv104_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c76c5b8f-1994-470c-a024-b97c73b9bb41"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ba45d071-0691-4fb5-a0fa-d9fbb2f0a8f1"}}}}, {"uuid": "79e38f7e-8b83-4854-b01a-4431739ddef2", "name": "eeefaf38-2a4e-4ed2-a228-202d34333004_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.651721747239447, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.750976002130125, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d960e788-92fb-47d2-8fca-56b2768f1a29", "name": "b7563fdf-9304-4cbf-b1bc-ee9f9adad567", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "79e38f7e-8b83-4854-b01a-4431739ddef2"}}}]}, {"uuid": "bd4d9be8-ecf0-4c23-82f2-e58b4760da60", "name": "load_p1rlv104_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c76c5b8f-1994-470c-a024-b97c73b9bb41"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d960e788-92fb-47d2-8fca-56b2768f1a29"}}}}, {"uuid": "2e8536ec-1a2e-4e27-85a8-b467888ca835", "name": "13b2f988-564c-443c-baad-c2eb203cf2aa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c1ec30df-0bdb-4026-9bc4-a04b856b74e9", "name": "140b9b1c-e959-4ce0-bffa-25f4579b2333", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2e8536ec-1a2e-4e27-85a8-b467888ca835"}}}]}, {"uuid": "d8bfa8fc-8fbd-4255-90e5-e27ccaaa2648", "name": "load_p1rlv105_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fe82ede-430d-454d-b9d0-e212d0621ea1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c1ec30df-0bdb-4026-9bc4-a04b856b74e9"}}}}, {"uuid": "f8007fef-a4cb-415b-a99b-a5914e404d70", "name": "7684eece-222c-4a8a-92f3-bc8020f4d912_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3105f80b-d304-4233-a025-1f6c2ecd50d3", "name": "4f238f30-c677-4975-a961-050e8ea1bed9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8007fef-a4cb-415b-a99b-a5914e404d70"}}}]}, {"uuid": "578f8926-bd9e-4b24-a882-5acb77252820", "name": "load_p1rlv105_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fe82ede-430d-454d-b9d0-e212d0621ea1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3105f80b-d304-4233-a025-1f6c2ecd50d3"}}}}, {"uuid": "14fae872-1b77-45ce-add0-e7976b3630fd", "name": "ed854caa-4326-4a77-93b2-0b14fe09ff85_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.30121669259111117, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.11773911124465561, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9b677954-9657-4c65-ba63-087dba6ab1bb", "name": "f6bc12e0-cfc4-4bc2-b323-86d2ea685920", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "14fae872-1b77-45ce-add0-e7976b3630fd"}}}]}, {"uuid": "f6200b6c-6b46-41fb-b3c5-1862a8054e9d", "name": "load_p1rlv107_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "096e92a6-ea34-435e-a059-57d5234e1654"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9b677954-9657-4c65-ba63-087dba6ab1bb"}}}}, {"uuid": "8ae42569-ca98-43cd-a5f8-37969e71c278", "name": "5691c38e-10b3-48f2-bf5a-2fe899952497_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.30121669259111117, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.11773911124465561, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3c6b4294-6bed-4537-9fa8-ee36816240ed", "name": "63298650-1925-432c-800a-ed81441ae492", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ae42569-ca98-43cd-a5f8-37969e71c278"}}}]}, {"uuid": "ffaf6895-8364-48e3-8054-1985456b2eab", "name": "load_p1rlv107_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "096e92a6-ea34-435e-a059-57d5234e1654"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3c6b4294-6bed-4537-9fa8-ee36816240ed"}}}}, {"uuid": "c35b2abf-c50e-4d68-ad3d-9ae50af82d54", "name": "d0ef8001-1275-4a80-a82a-0af9540d10b9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.522559572152904, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23989402539717328, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e88bd1c6-bc36-40cd-b0c1-7c15933cc79f", "name": "e42ef0cb-6e24-4453-a4b7-866902a90c1e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c35b2abf-c50e-4d68-ad3d-9ae50af82d54"}}}]}, {"uuid": "069c0311-57f5-4fb5-9df1-29924928c296", "name": "load_p1rlv108_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "afc70b80-ab76-440c-b05b-149458051675"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e88bd1c6-bc36-40cd-b0c1-7c15933cc79f"}}}}, {"uuid": "71b788fb-ce89-48a2-aceb-69953c603aab", "name": "79c06ebe-683b-49e5-ad12-61270762b53d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.522559572152904, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23989402539717328, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cf8a5e2f-b19e-41a5-8bff-338e32c1e09c", "name": "fa4c6444-08bd-47a2-97ed-04ada0ff6b1e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "71b788fb-ce89-48a2-aceb-69953c603aab"}}}]}, {"uuid": "3fd99e63-6ab6-44a5-b868-531cf263e5f9", "name": "load_p1rlv108_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "afc70b80-ab76-440c-b05b-149458051675"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cf8a5e2f-b19e-41a5-8bff-338e32c1e09c"}}}}, {"uuid": "8f1d6e19-6d64-4f97-855a-c6626c5778af", "name": "b3e647d6-daaa-422c-871a-4016fbbdddf6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5369480608064634, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2969034126636569, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "516685fd-7351-4510-9728-85aacad9a207", "name": "55c7787a-4d3a-4737-a3a5-8165bcc1d472", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8f1d6e19-6d64-4f97-855a-c6626c5778af"}}}]}, {"uuid": "054abb3b-f1d6-4857-817d-e614797894a3", "name": "load_p1rlv109_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c76fc99c-c160-4ed0-85dd-ec3da962bb24"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "516685fd-7351-4510-9728-85aacad9a207"}}}}, {"uuid": "d62c79c8-4ebc-4d85-9274-1a052f286007", "name": "5ba0d181-1f41-4828-9153-763fc26a1566_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5369480608064634, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2969034126636569, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c979a193-0990-4901-a9ce-244a39c8b763", "name": "ae7c6d8c-3bfe-4e99-8b38-53f7bc6eef9e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d62c79c8-4ebc-4d85-9274-1a052f286007"}}}]}, {"uuid": "1650bce1-bb01-4df4-84aa-eea243ec7930", "name": "load_p1rlv109_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c76fc99c-c160-4ed0-85dd-ec3da962bb24"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c979a193-0990-4901-a9ce-244a39c8b763"}}}}, {"uuid": "24517943-5fde-4054-a339-befca697a048", "name": "4a5ecdab-80cf-4c43-aa11-c20c7ec88038_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4292209363155218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1643515800752328, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f171827b-d16c-4336-9893-c9d50b9e59e0", "name": "b14c8827-88b8-436f-9b1f-b3b1d850c4cf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "24517943-5fde-4054-a339-befca697a048"}}}]}, {"uuid": "d765a2ab-2053-435f-8de7-4c64abc39b0e", "name": "load_p1rlv111_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66748ae6-b6ef-4228-bb0f-f9a121f0e1a3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f171827b-d16c-4336-9893-c9d50b9e59e0"}}}}, {"uuid": "5b0e7b80-45b2-493b-8d9c-424d3d62917b", "name": "d450675c-b18c-41b0-a158-ea2f17f93e06_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4292209363155218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1643515800752328, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f5ab6d2-eb37-49ce-b90a-6435b99c77cd", "name": "3502e7b3-7a68-4ce9-8819-f7679319c5e4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b0e7b80-45b2-493b-8d9c-424d3d62917b"}}}]}, {"uuid": "072461f1-614b-4520-9bef-105e7407bd14", "name": "load_p1rlv111_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66748ae6-b6ef-4228-bb0f-f9a121f0e1a3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f5ab6d2-eb37-49ce-b90a-6435b99c77cd"}}}}, {"uuid": "a129d215-5479-4777-9afd-005fee86592b", "name": "35399736-e507-42af-9286-645d637ea53c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.554325896527151, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5828877012431191, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2ea15295-5d76-48a2-ad39-163db0210208", "name": "b60cd738-ea7d-451b-9fd2-10a38368b834", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a129d215-5479-4777-9afd-005fee86592b"}}}]}, {"uuid": "d37897bf-4995-482d-afae-238a3e5a4765", "name": "load_p1rlv112_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25edc94b-a44b-4200-8cde-73941c2818b8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2ea15295-5d76-48a2-ad39-163db0210208"}}}}, {"uuid": "0ad87fe1-fd4e-495a-a783-359e0194239e", "name": "c665dc92-5a1c-489b-947b-d94f6473342b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.554325896527151, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5828877012431191, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5d7aca6c-9fb3-4efd-9124-b1b7c09671cc", "name": "c95acac6-e43d-4abf-96a7-26ee5bd498a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0ad87fe1-fd4e-495a-a783-359e0194239e"}}}]}, {"uuid": "52b08107-3aaf-466d-aaa2-91607658bc6a", "name": "load_p1rlv112_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25edc94b-a44b-4200-8cde-73941c2818b8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5d7aca6c-9fb3-4efd-9124-b1b7c09671cc"}}}}, {"uuid": "f55f35ca-f906-479e-ada5-5b15d640dd78", "name": "0391e0ae-e8b6-4758-af68-2b1e73941310_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0288569450045768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2608148575838028, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5d05da5e-7c57-4473-894a-9cbd25435b09", "name": "ec30e385-acc1-45b8-ad4f-a7e08a1a93d0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f55f35ca-f906-479e-ada5-5b15d640dd78"}}}]}, {"uuid": "e5606f88-9627-4fde-819e-6a380b5a979b", "name": "load_p1rlv113_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2756378a-0c67-47cf-969d-bdb9e55c8a4b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5d05da5e-7c57-4473-894a-9cbd25435b09"}}}}, {"uuid": "35a42fc6-3d27-405c-b689-6461c37d0bf0", "name": "2e8e1a08-4c19-4975-a423-2bf62e7d8243_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0288569450045768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2608148575838028, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "663fbd3f-6296-4deb-8d4b-239d3aedb205", "name": "b241c0d4-30a7-46eb-bbf8-ae3c01cdc319", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "35a42fc6-3d27-405c-b689-6461c37d0bf0"}}}]}, {"uuid": "42b5dc58-5ed3-42bb-a34e-9f6785057db3", "name": "load_p1rlv113_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2756378a-0c67-47cf-969d-bdb9e55c8a4b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "663fbd3f-6296-4deb-8d4b-239d3aedb205"}}}}, {"uuid": "ee0e5033-82a3-4694-bbb8-33ad3d267e04", "name": "a7547c44-ed9f-4704-a038-b3fbd10d21a0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7419011483459746, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17632142927590772, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c8eeb9e6-96c3-4a2b-bc38-71d012f39165", "name": "50f3db76-64cf-4e1b-a57e-c7172cc3fa46", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ee0e5033-82a3-4694-bbb8-33ad3d267e04"}}}]}, {"uuid": "a14b9591-bce8-4a3f-9c90-e1f4b8a6954b", "name": "load_p1rlv114_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7934cd3-dcd6-4b67-8206-8a3636b6f75d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c8eeb9e6-96c3-4a2b-bc38-71d012f39165"}}}}, {"uuid": "9f118354-5ba0-4d57-b544-d315fa665779", "name": "197f306d-8b59-49a8-b384-bec24c9297a5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7419011483459746, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17632142927590772, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "97559216-4f7a-4506-b67e-9278e3f53e4c", "name": "5b8e997f-2eae-4714-9dc7-c452c92d4a90", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9f118354-5ba0-4d57-b544-d315fa665779"}}}]}, {"uuid": "9d62d752-2c7b-4ee0-8f15-1839d9751b31", "name": "load_p1rlv114_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7934cd3-dcd6-4b67-8206-8a3636b6f75d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "97559216-4f7a-4506-b67e-9278e3f53e4c"}}}}, {"uuid": "b6fd0128-bc95-4086-9e43-7c8ccf220076", "name": "5cd4b925-275d-4ca5-b7bd-64fda137a71d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.883515343353138, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18989418857380705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "878e8f33-af62-487e-9af6-6d0c498d84c8", "name": "8e522171-e97f-471d-8866-b02f7a5f77d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b6fd0128-bc95-4086-9e43-7c8ccf220076"}}}]}, {"uuid": "57839523-1c75-459f-a365-3cd8fbb9fde7", "name": "load_p1rlv115_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "919a48e8-b378-4dd5-8e33-a2602fb58bc0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "878e8f33-af62-487e-9af6-6d0c498d84c8"}}}}, {"uuid": "862cf827-2fa0-4e3a-9d53-d3de3cfff5ee", "name": "1b7f0e82-7b47-4d9b-ac23-d5091debc8bf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.883515343353138, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18989418857380705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1ff35b48-6c02-4af4-943b-a9c4140b8678", "name": "9b5134e1-42e0-4eee-a0b1-f27c6d61ab86", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "862cf827-2fa0-4e3a-9d53-d3de3cfff5ee"}}}]}, {"uuid": "a5b6fcd7-3c22-4997-bb4a-90ad17d41503", "name": "load_p1rlv115_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "919a48e8-b378-4dd5-8e33-a2602fb58bc0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1ff35b48-6c02-4af4-943b-a9c4140b8678"}}}}, {"uuid": "23f0b4e3-06ad-46a0-8acb-16543172da24", "name": "19b07006-31d9-4290-bbb7-26a3a12507fd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7362273540893955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24527287728713068, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e1548353-7017-48de-a9e3-439c9a0bba57", "name": "85aa85ca-0027-4da8-b581-95318cc8a814", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "23f0b4e3-06ad-46a0-8acb-16543172da24"}}}]}, {"uuid": "b5abfb5c-782d-4495-9bd1-e78f868ffb9d", "name": "load_p1rlv117_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e6de569-7f61-439e-a402-850c4f071ab3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e1548353-7017-48de-a9e3-439c9a0bba57"}}}}, {"uuid": "53447ca1-e6c3-4a00-9395-443683755039", "name": "a1db1749-39b2-4dc5-9bb5-b31dca0be6c1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7362273540893955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24527287728713068, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2d59efa9-d691-4ccc-b6a5-27c0fc8f2426", "name": "2f4bafcf-2bc3-4dcc-86e1-1a9567cbaf83", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "53447ca1-e6c3-4a00-9395-443683755039"}}}]}, {"uuid": "80f37d62-ee74-4124-a567-ee5a167a8543", "name": "load_p1rlv117_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e6de569-7f61-439e-a402-850c4f071ab3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2d59efa9-d691-4ccc-b6a5-27c0fc8f2426"}}}}, {"uuid": "e2e4aab7-cf99-48e7-8453-2f94b42aff45", "name": "806914aa-76f2-4988-b1d7-30aca0006156_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.074192704000552, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.129078804753558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "59d83935-cfff-4b37-9176-83da5cd721ff", "name": "98dea8e0-46fc-4d34-bf83-c423a96b79c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e2e4aab7-cf99-48e7-8453-2f94b42aff45"}}}]}, {"uuid": "4e09f639-e11f-4eab-89f1-fafcd4d8cb28", "name": "load_p1rlv118_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "247e37b3-d6d0-41d7-a6b3-ee29d415da50"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "59d83935-cfff-4b37-9176-83da5cd721ff"}}}}, {"uuid": "84bb5902-a714-4e27-aa5d-9b93b75ab90a", "name": "d3b07c70-907f-49c6-b00f-8af495f1e472_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.074192704000552, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.129078804753558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e8ec978d-abb5-4c1a-9abc-40e33eaad1f7", "name": "cefc2605-e448-422f-b93b-4c11333bf9fd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "84bb5902-a714-4e27-aa5d-9b93b75ab90a"}}}]}, {"uuid": "72198056-05f5-4903-8c74-c691d4a32759", "name": "load_p1rlv118_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "247e37b3-d6d0-41d7-a6b3-ee29d415da50"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e8ec978d-abb5-4c1a-9abc-40e33eaad1f7"}}}}, {"uuid": "719a89dd-b219-461d-81df-9f94b751432c", "name": "72182001-19d6-49c5-900d-f269aff2bea9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9571923411347831, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7946531538551662, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "59b30b42-f074-4170-92eb-b8bca83fa949", "name": "9bf0adc2-c199-423c-9395-851dadee10ea", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "719a89dd-b219-461d-81df-9f94b751432c"}}}]}, {"uuid": "33eaf0d1-0bf8-44c0-b0e5-452a215c3cb7", "name": "load_p1rlv119_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee33d90b-2f70-4c9d-863d-6486b95280b8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "59b30b42-f074-4170-92eb-b8bca83fa949"}}}}, {"uuid": "a8d19fde-9e9f-4fbf-8126-909580c17469", "name": "4e0c6550-e775-46e3-9879-acb13d1bdc30_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9571923411347831, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7946531538551662, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "583f5ac1-4c54-4883-8660-c250b7e3cb04", "name": "33bc3b30-57e1-46aa-bc52-31df7304976a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a8d19fde-9e9f-4fbf-8126-909580c17469"}}}]}, {"uuid": "cfe435c8-1fe6-4078-bdb4-a7d971412db5", "name": "load_p1rlv119_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee33d90b-2f70-4c9d-863d-6486b95280b8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "583f5ac1-4c54-4883-8660-c250b7e3cb04"}}}}, {"uuid": "27bf5446-2162-4885-b371-253ccb53de9b", "name": "f8adb0fa-f9c1-493e-b521-27f42c67975b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.297832728168154, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6109723215697453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4611dda0-db86-4242-915a-95dba9b96f8d", "name": "b7856dc6-74d1-4807-a9ee-fc7deb551e87", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "27bf5446-2162-4885-b371-253ccb53de9b"}}}]}, {"uuid": "82a70d6b-169a-4b40-8005-32e139b77ad0", "name": "load_p1rlv120_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a02925cd-7c5b-475f-9e91-30d639bb3c33"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4611dda0-db86-4242-915a-95dba9b96f8d"}}}}, {"uuid": "fad7872b-c335-45bc-aa98-e49b2eca9feb", "name": "ab1c6fed-c9bf-41cb-9a4b-bedce3492fb6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.297832728168154, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6109723215697453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b8fd66d8-f1ee-4917-b670-e9270f82689d", "name": "8566d8fa-2057-401d-860c-630f8ef812f8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fad7872b-c335-45bc-aa98-e49b2eca9feb"}}}]}, {"uuid": "7630ba82-773b-4559-9b9c-8880d22169e5", "name": "load_p1rlv120_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a02925cd-7c5b-475f-9e91-30d639bb3c33"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b8fd66d8-f1ee-4917-b670-e9270f82689d"}}}}, {"uuid": "13b895c5-18b1-4554-a332-4f8bdb4cb7e6", "name": "051a4bcc-e931-46ee-9d3c-808bd76a3c3f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.876043044068563, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8047319040687714, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e59e9b91-2be7-427f-8d2a-b439f06209a6", "name": "fada6878-7d42-49a2-807e-377e437143ff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "13b895c5-18b1-4554-a332-4f8bdb4cb7e6"}}}]}, {"uuid": "afb00e2d-1f8c-48e1-8edf-bb710714ed07", "name": "load_p1rlv121_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0dbaab50-3abc-4207-82dc-5fcc5be68aad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e59e9b91-2be7-427f-8d2a-b439f06209a6"}}}}, {"uuid": "a27d63eb-6dcd-40dc-8442-7c8671032d02", "name": "857e4ea9-3b0f-4208-9244-0af42af4a7e3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.876043044068563, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8047319040687714, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2718d551-8cf3-4600-9dc3-b4c3665e8a0e", "name": "33a47752-67d3-4b44-bde6-d9c114f75f21", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a27d63eb-6dcd-40dc-8442-7c8671032d02"}}}]}, {"uuid": "8ce1fecd-0c60-473b-869a-8a5bf9ff6166", "name": "load_p1rlv121_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0dbaab50-3abc-4207-82dc-5fcc5be68aad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2718d551-8cf3-4600-9dc3-b4c3665e8a0e"}}}}, {"uuid": "49b0e4ba-7ca3-4d34-af13-7e25824e6a76", "name": "1b47beed-07a2-45ae-b215-79e50838f478_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2437699409140923, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5571842941855458, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "84efaaec-d9f7-483f-9ab6-fc0a55a52f8c", "name": "7e10c91e-d599-4df1-a1fe-96851d0cf4a5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "49b0e4ba-7ca3-4d34-af13-7e25824e6a76"}}}]}, {"uuid": "e595319f-e5d3-498c-a031-e65dbe57223c", "name": "load_p1rlv122_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b02739e-d082-4c54-8deb-8ccc83ab82ab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "84efaaec-d9f7-483f-9ab6-fc0a55a52f8c"}}}}, {"uuid": "962e79fe-c222-4e40-9c9f-abbc2ce59cb0", "name": "067aa084-2c75-4d15-97aa-78b3e0b0a153_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2437699409140923, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5571842941855458, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7fa14ede-ebce-495f-9e9f-41b61144d1ff", "name": "3ad50f32-b317-4906-82aa-07733944795c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "962e79fe-c222-4e40-9c9f-abbc2ce59cb0"}}}]}, {"uuid": "eeffb200-c11b-446a-a198-cb403bac7beb", "name": "load_p1rlv122_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b02739e-d082-4c54-8deb-8ccc83ab82ab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7fa14ede-ebce-495f-9e9f-41b61144d1ff"}}}}, {"uuid": "8baad36a-cd5c-4c30-adee-29e71781f3fd", "name": "0dfa85db-08dc-409e-970c-c904c5c307bf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9353742885016981, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3630006054680373, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3c97fce8-7ca0-4309-b2eb-511d255f7ca8", "name": "b2bdc887-8e68-4385-a40f-325bfc8eab82", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8baad36a-cd5c-4c30-adee-29e71781f3fd"}}}]}, {"uuid": "f81f35ba-48df-4e21-9762-47dd4726f97d", "name": "load_p1rlv123_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6184fe8d-ae60-426a-8c0c-a3cc56c5b67e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3c97fce8-7ca0-4309-b2eb-511d255f7ca8"}}}}, {"uuid": "78b81e4a-3d2f-426f-b57f-85fbb095427c", "name": "c66c5166-c614-43f0-b2ea-ec48f019e1a1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9353742885016981, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3630006054680373, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4f4521b7-d7f6-4ec4-acff-ed7bc763dae0", "name": "416a179a-0784-4248-a2eb-67f0088efceb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "78b81e4a-3d2f-426f-b57f-85fbb095427c"}}}]}, {"uuid": "7c31539f-f638-4d65-965a-9d3ea5776d58", "name": "load_p1rlv123_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6184fe8d-ae60-426a-8c0c-a3cc56c5b67e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4f4521b7-d7f6-4ec4-acff-ed7bc763dae0"}}}}, {"uuid": "b3b2c077-f49b-4ef2-a732-d105b0c18c23", "name": "564c20b2-c549-4e21-a5d2-8ad1ba2d061a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4794755457968312, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.46197673612457824, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0fd74c8f-5b7d-440d-ab7b-58c8362163a4", "name": "e570946e-a438-4421-bcc5-7d72ca2612b9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b3b2c077-f49b-4ef2-a732-d105b0c18c23"}}}]}, {"uuid": "686de60c-d247-410b-b7f5-5fcfa2b57dd2", "name": "load_p1rlv124_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e5ca78b-6151-4a35-8a04-1bab215f0f10"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0fd74c8f-5b7d-440d-ab7b-58c8362163a4"}}}}, {"uuid": "3fda8210-f058-400a-95f6-942ca84ae691", "name": "1ce44c52-127a-4e74-b8ef-551022d11d8e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4794755457968312, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.46197673612457824, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b1c9a482-b6ba-4487-9ea8-6c9b7b2aa794", "name": "6aee4861-997c-47f7-a71a-8e27165836d7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3fda8210-f058-400a-95f6-942ca84ae691"}}}]}, {"uuid": "ae132a9a-c8c1-4756-9475-eaee18f1b99a", "name": "load_p1rlv124_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e5ca78b-6151-4a35-8a04-1bab215f0f10"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b1c9a482-b6ba-4487-9ea8-6c9b7b2aa794"}}}}, {"uuid": "b612dfd9-e950-4218-9a85-4200a50d317b", "name": "d1a68747-d3aa-44a9-8aa7-2f4992abe586_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "93059b3a-00fa-44b9-9ad6-92cd637f51fe", "name": "53bd28d2-e9a5-4b07-8ae7-1ed70eb98476", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b612dfd9-e950-4218-9a85-4200a50d317b"}}}]}, {"uuid": "b1748623-6759-4b31-93a1-5bf78c59fb76", "name": "load_p1rlv125_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3367cc2-b096-4cfb-ae71-038eb9e06b46"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "93059b3a-00fa-44b9-9ad6-92cd637f51fe"}}}}, {"uuid": "4c023815-5ad6-4f31-95d2-146176a71953", "name": "fcc40596-9760-41d7-94ed-8f6f7cd31098_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4a3e0581-451c-4c23-a56f-cf3fe911cef8", "name": "fe993a5d-8671-43a7-8e67-9d9689673f1d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4c023815-5ad6-4f31-95d2-146176a71953"}}}]}, {"uuid": "37e8cddf-d42e-4ce9-885b-d33d9cfe3388", "name": "load_p1rlv125_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3367cc2-b096-4cfb-ae71-038eb9e06b46"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4a3e0581-451c-4c23-a56f-cf3fe911cef8"}}}}, {"uuid": "8d060410-1b28-4508-841f-1a239a00d098", "name": "bea2eb65-94f6-44d6-a077-5c7ecacd7036_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5229589832640044, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3359880712066463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e4521922-851e-47ab-bd82-4c196fade484", "name": "a34ea912-dd78-4e06-8965-d6a42c1c87db", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8d060410-1b28-4508-841f-1a239a00d098"}}}]}, {"uuid": "4ef7ff68-ddbb-4dc5-8c3a-fd7218a0591c", "name": "load_p1rlv127_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ae7b1fe-08c4-4848-867e-e2426a325a99"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e4521922-851e-47ab-bd82-4c196fade484"}}}}, {"uuid": "9d1fb586-95ba-4e57-889e-356da6c25cb4", "name": "c59cec42-74f7-4e00-b345-b23208a2b15f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5229589832640044, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3359880712066463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fee10c7c-3ab1-48aa-b412-8bd7d2573dce", "name": "9b24d381-d5f0-43e9-bb9c-fa7a959c0857", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9d1fb586-95ba-4e57-889e-356da6c25cb4"}}}]}, {"uuid": "ac210a2b-1851-4e76-816d-e4e7b4899f93", "name": "load_p1rlv127_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ae7b1fe-08c4-4848-867e-e2426a325a99"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fee10c7c-3ab1-48aa-b412-8bd7d2573dce"}}}}, {"uuid": "b2b15cde-b33b-4e37-b2cf-5316406072de", "name": "64283c63-b3dc-4aee-bf3c-cc0f8573e2f1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4040789998842194, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4565305929598704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "79f9cf11-c820-47a1-9b74-f7369ae38b9f", "name": "47ef9dc3-4340-4d69-b3a7-a480ff9a4e5b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b2b15cde-b33b-4e37-b2cf-5316406072de"}}}]}, {"uuid": "cec1091b-7501-4f4e-b710-95c483f07f5d", "name": "load_p1rlv128_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56bc8935-c658-424c-83d8-0d13bf8d292a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "79f9cf11-c820-47a1-9b74-f7369ae38b9f"}}}}, {"uuid": "f8773ad2-a5dd-4a15-9301-b781dc157354", "name": "ca7087ae-5b39-413c-a0fc-bee47dafc86e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4040789998842194, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4565305929598704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "732c4bbf-d4bf-4149-8316-f476c8c78a2d", "name": "06b6bbb7-9c54-4598-b096-9dc27b8102b1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8773ad2-a5dd-4a15-9301-b781dc157354"}}}]}, {"uuid": "f9ac8698-72e1-42bb-90f8-d43a78c28a3d", "name": "load_p1rlv128_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56bc8935-c658-424c-83d8-0d13bf8d292a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "732c4bbf-d4bf-4149-8316-f476c8c78a2d"}}}}, {"uuid": "eedc1026-34be-47de-a2e0-f3e6ea500bf1", "name": "6b5e0677-f402-49ad-b4ac-193d1f15bed2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7537427041030689, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.37349948863112625, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4574fab1-142f-4cb8-a0b1-dac68b4ab565", "name": "3c75864d-6bb4-4f6f-9f9b-72ae7985f0fd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eedc1026-34be-47de-a2e0-f3e6ea500bf1"}}}]}, {"uuid": "d7f4afb4-7503-4c66-8194-4661a71cb399", "name": "load_p1rlv129_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6c42586-4f46-45c6-910f-90fca771cfd2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4574fab1-142f-4cb8-a0b1-dac68b4ab565"}}}}, {"uuid": "24d808e0-a25d-41bc-8aaf-9990eccb7ab4", "name": "56088df8-55c7-4fdc-896a-5f04e6ccb015_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7537427041030689, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.37349948863112625, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f39fe77-3d73-48ab-92ba-9fb9f8622ce2", "name": "f250c745-893d-400e-85f3-dccb3b92119b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "24d808e0-a25d-41bc-8aaf-9990eccb7ab4"}}}]}, {"uuid": "d92713c4-e2f3-475e-80e6-43f4332b0f7c", "name": "load_p1rlv129_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6c42586-4f46-45c6-910f-90fca771cfd2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f39fe77-3d73-48ab-92ba-9fb9f8622ce2"}}}}, {"uuid": "7206e78c-dc01-4a88-87dc-92f12b81c5ed", "name": "85c77c54-09b7-4b11-99df-3d2d2fb35559_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.297832728168154, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6109723215697453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4a29d63e-dea1-442d-a272-760c694e029c", "name": "9222c3b6-9c12-463a-8ec0-a7a065b61a82", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7206e78c-dc01-4a88-87dc-92f12b81c5ed"}}}]}, {"uuid": "c0a5d83c-19a2-4bbe-b430-96cd86c3ec5d", "name": "load_p1rlv130_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5c96953-6710-4765-b5bd-4359e03e4c63"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4a29d63e-dea1-442d-a272-760c694e029c"}}}}, {"uuid": "79588cfd-8b16-4b36-a195-5326be554ce5", "name": "a1928b35-55c4-4a97-bb90-117bc2179089_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.297832728168154, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6109723215697453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "780efec7-3429-400e-826c-6f883f72604d", "name": "36491887-4033-4fee-a6d9-2f3cac618305", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "79588cfd-8b16-4b36-a195-5326be554ce5"}}}]}, {"uuid": "7e42a97a-9ca0-445f-89dc-e988ed19372b", "name": "load_p1rlv130_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5c96953-6710-4765-b5bd-4359e03e4c63"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "780efec7-3429-400e-826c-6f883f72604d"}}}}, {"uuid": "9b2700f3-4011-4344-bdf5-7dc7f7441c55", "name": "3e5929fc-8438-437c-8433-c5f322bc79ba_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3885774782241163, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12624891415512582, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "390771cc-dc65-47c4-8419-4787ae8f5e54", "name": "b665265e-dc12-4058-8a80-9a4aaf2a8bcf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9b2700f3-4011-4344-bdf5-7dc7f7441c55"}}}]}, {"uuid": "5413e231-368b-4a65-8ed8-a723bdf8923d", "name": "load_p1rlv131_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "499fb461-ccb6-436a-8078-eec9beffb4a9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "390771cc-dc65-47c4-8419-4787ae8f5e54"}}}}, {"uuid": "c4778803-e672-41a7-94e1-30a30aa54414", "name": "343e43df-a998-42a9-a472-71fac05ed739_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3885774782241163, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12624891415512582, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1822e842-8251-466f-b5a8-9dfbd1cf9d26", "name": "747b0fbe-bcf2-4d83-b894-a7ebfa1d1448", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c4778803-e672-41a7-94e1-30a30aa54414"}}}]}, {"uuid": "3a3aa4b8-ceae-4213-a03e-7a8dc52d0961", "name": "load_p1rlv131_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "499fb461-ccb6-436a-8078-eec9beffb4a9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1822e842-8251-466f-b5a8-9dfbd1cf9d26"}}}}, {"uuid": "39b9e37a-0501-4cc6-b4a9-74a2fc2b9cf0", "name": "8a32d994-7583-4752-b441-2f6e02dd5b1d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0137187800791063, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5284248988065299, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8e10c4cb-8e1d-4851-8987-ae9eace6d8d0", "name": "f6478ee6-3a57-4bba-94ee-56361b3e3858", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "39b9e37a-0501-4cc6-b4a9-74a2fc2b9cf0"}}}]}, {"uuid": "3f42414d-fc02-43d7-91a3-6ad9eb55c592", "name": "load_p1rlv132_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41960437-e2e6-4746-89c2-81c81602ca1b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8e10c4cb-8e1d-4851-8987-ae9eace6d8d0"}}}}, {"uuid": "69280a7b-28c9-4d85-877f-dd1248b7248b", "name": "1f19a2e4-25a5-407b-8454-2be5b63972a5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0137187800791063, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5284248988065299, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "164140b5-919a-4b39-93e9-6db867cf4762", "name": "7fb42886-cae4-444b-92db-facbd41dab72", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "69280a7b-28c9-4d85-877f-dd1248b7248b"}}}]}, {"uuid": "ae0dee1d-c463-4e8f-ae0a-82810bc1685d", "name": "load_p1rlv132_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41960437-e2e6-4746-89c2-81c81602ca1b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "164140b5-919a-4b39-93e9-6db867cf4762"}}}}, {"uuid": "fb417fec-33bd-4084-8f82-6d11748f2047", "name": "a9795b2b-4b87-4110-8a14-78afd0d49d64_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.046232297850773, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7285366000251032, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3064bd57-4ffc-4deb-8735-6d075a485d9f", "name": "96357b25-56ee-4f8d-9da2-a3e83610934a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fb417fec-33bd-4084-8f82-6d11748f2047"}}}]}, {"uuid": "e3f43d0b-7c14-40bf-8d16-648e9e170049", "name": "load_p1rlv133_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31dc8280-eb14-4f87-85d7-8eae17013fe7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3064bd57-4ffc-4deb-8735-6d075a485d9f"}}}}, {"uuid": "f985227a-08b1-43a1-8e47-a22acac88d68", "name": "710369ac-a8d0-4c38-93a8-46b84dd1d8a7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.046232297850773, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7285366000251032, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d3331dab-f1a0-40fa-81e9-63713ffc2b94", "name": "f3f63640-6d2d-44e9-9790-fa94d65bf3a0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f985227a-08b1-43a1-8e47-a22acac88d68"}}}]}, {"uuid": "a4597a71-10a4-4e27-b3cf-0a95e3532ec2", "name": "load_p1rlv133_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31dc8280-eb14-4f87-85d7-8eae17013fe7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d3331dab-f1a0-40fa-81e9-63713ffc2b94"}}}}, {"uuid": "c93cb390-e017-4571-8bdc-951a3c7934e2", "name": "09bdff91-2037-4c18-ba7b-a04c66ed49b6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.749950841708346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2019248045205122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c73fef17-c587-4230-b668-dff1db537a28", "name": "154ddc07-d012-4fdd-9991-5b1ca9c716dd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c93cb390-e017-4571-8bdc-951a3c7934e2"}}}]}, {"uuid": "347cf23e-5bb8-4ca9-bf4c-f95fe4d6aed4", "name": "load_p1rlv134_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "425bdcfa-9753-4ef5-bb38-9e014ae779dc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c73fef17-c587-4230-b668-dff1db537a28"}}}}, {"uuid": "a92c0e23-02e5-4950-8be3-f8c9e8c4591d", "name": "2a8bc7d6-7297-4097-8dfd-1c6494a98a65_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.749950841708346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2019248045205122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e19a7870-8be5-4d5e-8652-16b430939a8d", "name": "868745ea-71dc-4326-a57b-7f61af0d2ab9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a92c0e23-02e5-4950-8be3-f8c9e8c4591d"}}}]}, {"uuid": "266eefbd-2122-4ee6-9540-516ad6889ef8", "name": "load_p1rlv134_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "425bdcfa-9753-4ef5-bb38-9e014ae779dc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e19a7870-8be5-4d5e-8652-16b430939a8d"}}}}, {"uuid": "95ec5f2b-b490-42f4-8ee2-9ca02be4da2c", "name": "45df5033-41fe-4d79-b003-347016b718a8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.42648220197083947, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17627708866943506, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d5775010-abb6-406d-84d4-10da14e4a029", "name": "fb2cf978-0429-4a12-969a-5bb046e1aa57", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "95ec5f2b-b490-42f4-8ee2-9ca02be4da2c"}}}]}, {"uuid": "941505d8-b4bb-420d-ad6e-167a2ebd2c3a", "name": "load_p1rlv135_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbdefe7a-517b-495b-88b8-dcf15a9429ff"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d5775010-abb6-406d-84d4-10da14e4a029"}}}}, {"uuid": "bad99740-a014-4f26-bf2e-7387137923c8", "name": "79792ac0-069b-447a-a970-b0bc553883d1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.42648220197083947, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17627708866943506, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50f95d46-0ac6-48ff-95ad-00338df71ef2", "name": "0394e936-e0cc-4fd8-8fcc-9cfc4332f150", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bad99740-a014-4f26-bf2e-7387137923c8"}}}]}, {"uuid": "bc126c2c-755e-4200-8d8f-962a94855b9c", "name": "load_p1rlv135_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbdefe7a-517b-495b-88b8-dcf15a9429ff"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50f95d46-0ac6-48ff-95ad-00338df71ef2"}}}}, {"uuid": "9f3b6ec2-dfbd-409b-a2c6-525a9ff654ff", "name": "39164d37-47d5-414e-8a10-a40a4ab83b24_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.42648220197083947, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17627708866943506, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d0e4956c-feaf-42b5-9ee4-c963a2a26935", "name": "15277c3b-7fa8-4388-a600-0b7f97c905a4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9f3b6ec2-dfbd-409b-a2c6-525a9ff654ff"}}}]}, {"uuid": "2d231a9c-7512-4f43-8277-1487fc229652", "name": "load_p1rlv136_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b45d086e-8e0d-42f4-a8ec-6d3a9579a96b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d0e4956c-feaf-42b5-9ee4-c963a2a26935"}}}}, {"uuid": "fdafdf3b-73b3-453a-87c2-2df8084bb98c", "name": "ca06e9b0-4117-4eff-bf25-bbfe498d6009_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.42648220197083947, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17627708866943506, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9cc6a9b8-8464-4424-b3b3-4d2cc9d97dd5", "name": "25312fce-d271-4992-a5e5-ddb8d59e7ff5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fdafdf3b-73b3-453a-87c2-2df8084bb98c"}}}]}, {"uuid": "1cdcc87f-f562-47be-91b4-f48dd1775575", "name": "load_p1rlv136_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b45d086e-8e0d-42f4-a8ec-6d3a9579a96b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9cc6a9b8-8464-4424-b3b3-4d2cc9d97dd5"}}}}, {"uuid": "0086126c-4d2d-4fc7-96e6-03d8d4cac9d3", "name": "f3fd3a9b-7921-449c-8770-15e549537819_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7847716543397305, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8567239737527961, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "505c74a3-c96f-4c02-a72f-d0f90e0437a1", "name": "a5512df3-8486-4353-af08-2fc11ccb626e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0086126c-4d2d-4fc7-96e6-03d8d4cac9d3"}}}]}, {"uuid": "c16d5956-bcaf-4e19-bbb4-a2d9c7c50985", "name": "load_p1rlv137_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54ca5205-5b71-42f2-8e24-c24f768a7a5c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "505c74a3-c96f-4c02-a72f-d0f90e0437a1"}}}}, {"uuid": "db699610-605d-413c-8ff6-f42b1562e0cf", "name": "286e5f6e-1ae8-4f8b-8acf-22c703327965_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7847716543397305, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8567239737527961, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6a7d692c-a117-4247-8287-b3f354c302fd", "name": "bbcd4a4f-a0ec-4892-93b6-87e6bf5f4997", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "db699610-605d-413c-8ff6-f42b1562e0cf"}}}]}, {"uuid": "b741fa39-d83e-4937-81da-2c267cac540d", "name": "load_p1rlv137_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54ca5205-5b71-42f2-8e24-c24f768a7a5c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6a7d692c-a117-4247-8287-b3f354c302fd"}}}}, {"uuid": "682e5096-46cf-4550-a322-c4ab8b58f66e", "name": "fa81627e-9a5c-4990-b78c-b6a34af2247d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3464174292990054, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8802812503815668, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f4389e8d-94fe-424c-ab95-9398108a0c98", "name": "02f8a4fb-67f2-46db-a057-566bd62223f2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "682e5096-46cf-4550-a322-c4ab8b58f66e"}}}]}, {"uuid": "a13d6162-7194-4ef1-9525-14c7daa057bc", "name": "load_p1rlv138_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea9e5f8c-8477-403c-9d3a-911c4e5ab5c8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f4389e8d-94fe-424c-ab95-9398108a0c98"}}}}, {"uuid": "31687a1d-b0c0-4fdf-b82d-bc308aabefd0", "name": "177ce2f3-6ac7-4c15-946b-12bb54870dea_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3464174292990054, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8802812503815668, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "95e0385d-8d99-4303-b089-6f2829172f7e", "name": "2dc4c056-d7cb-4f5b-a146-5befc5393a1a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "31687a1d-b0c0-4fdf-b82d-bc308aabefd0"}}}]}, {"uuid": "dcd3190d-0b75-48da-8b22-cc7d18a61203", "name": "load_p1rlv138_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea9e5f8c-8477-403c-9d3a-911c4e5ab5c8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "95e0385d-8d99-4303-b089-6f2829172f7e"}}}}, {"uuid": "b1a1e4ef-f08c-4195-99b1-234afd20d768", "name": "d35c880e-0ed2-4c1d-a930-f6984f03b3be_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d041a1dd-add3-4622-b9a3-3318ab972cfa", "name": "785d81d9-4a00-4d38-8461-704019109825", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b1a1e4ef-f08c-4195-99b1-234afd20d768"}}}]}, {"uuid": "9d10a1c4-d3ce-4795-a27d-1d6c70a0f364", "name": "load_p1rlv139_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b515111-3455-471a-aba8-92c82624a195"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d041a1dd-add3-4622-b9a3-3318ab972cfa"}}}}, {"uuid": "659e1f70-3a5c-4fe3-b175-ae2b937d5072", "name": "72b548ea-22ba-43cf-8b60-272236c601e5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "315adfbb-45bd-4aef-b975-b33240c1baaa", "name": "1bc333f7-d58e-4446-a171-8fb28b2036bd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "659e1f70-3a5c-4fe3-b175-ae2b937d5072"}}}]}, {"uuid": "d2dc7c04-36f4-41ec-9710-1fc569efcafc", "name": "load_p1rlv139_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b515111-3455-471a-aba8-92c82624a195"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "315adfbb-45bd-4aef-b975-b33240c1baaa"}}}}, {"uuid": "034b2e6c-75c2-4ec8-b37f-f667c33a99c5", "name": "088bc71c-b927-42da-9b52-f7e65500ea96_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.209150400251685, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2205162973996855, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "19a5d21e-61b9-463f-9019-13b26647196e", "name": "d56465c5-95d2-4be6-bfed-60413c14803f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "034b2e6c-75c2-4ec8-b37f-f667c33a99c5"}}}]}, {"uuid": "5f355174-2450-47b3-8699-e6f5ab544c8c", "name": "load_p1rlv140_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47b7d9f8-ca72-4a77-af67-74ee561f7f10"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "19a5d21e-61b9-463f-9019-13b26647196e"}}}}, {"uuid": "63bb7c2e-c2b4-40b4-b982-f5fa68dd616f", "name": "a7a86684-abbb-4eba-bb58-2664751d69a4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.209150400251685, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2205162973996855, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "15829817-4b74-4da6-8886-2ceb190a7d6a", "name": "26b8d213-19be-48eb-9e30-43b201a201e2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "63bb7c2e-c2b4-40b4-b982-f5fa68dd616f"}}}]}, {"uuid": "078efe7b-e8c2-4b0a-8724-18637fa38f8e", "name": "load_p1rlv140_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47b7d9f8-ca72-4a77-af67-74ee561f7f10"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "15829817-4b74-4da6-8886-2ceb190a7d6a"}}}}, {"uuid": "eda14cb6-5a95-4051-932e-1aaf61b27387", "name": "d6dac862-178a-429b-b99c-fdc55e6ecf30_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.151480398016275, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.11399865992730775, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "44a09194-ef66-4ffc-878e-d75e35308de7", "name": "4ebb344d-82dc-499a-9c40-c415cfc56f7b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eda14cb6-5a95-4051-932e-1aaf61b27387"}}}]}, {"uuid": "fc3a2ef7-4d6c-4256-850a-721c0c740e0d", "name": "load_p1rlv141_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb69a6a9-3eaf-4fc3-82be-0eec77455a82"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "44a09194-ef66-4ffc-878e-d75e35308de7"}}}}, {"uuid": "38871f1f-85b5-4b3b-af00-f94e78fd4eae", "name": "f5a7f030-cd46-44b6-a68d-99662bdd96d6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.151480398016275, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.11399865992730775, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ae6826a1-1972-422c-8398-5a8baefac133", "name": "ad2ef29a-cada-4bf4-a441-2bfd7068ee86", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "38871f1f-85b5-4b3b-af00-f94e78fd4eae"}}}]}, {"uuid": "ca231060-9de7-45a2-b588-e95b9061ebb8", "name": "load_p1rlv141_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb69a6a9-3eaf-4fc3-82be-0eec77455a82"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ae6826a1-1972-422c-8398-5a8baefac133"}}}}, {"uuid": "11514d8b-42b8-44ec-b770-f820efbc3626", "name": "b3b92ae2-3d05-4a7c-b72e-47c331e7a3f2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9029063430901945, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8881818750925909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b0adad72-9bdc-41ec-8a01-baf64e8da41f", "name": "bee29b63-4f88-4222-881d-7ad9afaad9c8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "11514d8b-42b8-44ec-b770-f820efbc3626"}}}]}, {"uuid": "c9a36645-5b3b-40d0-853e-4c24719fea23", "name": "load_p1rlv143_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "46cd88d0-b2c4-492a-af3d-d9ae886d0089"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b0adad72-9bdc-41ec-8a01-baf64e8da41f"}}}}, {"uuid": "8e1d9cc7-4be8-4426-beb6-ad38017a7ab5", "name": "8e55faaf-86ba-45d3-9a60-33e353e2969a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9029063430901945, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8881818750925909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b5c00744-639c-41ea-96ca-c1f09800fc3a", "name": "66ff36d7-5b31-4475-84ee-e223b11c1d90", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8e1d9cc7-4be8-4426-beb6-ad38017a7ab5"}}}]}, {"uuid": "b13f3e78-16f0-46ea-a28a-6bd223312662", "name": "load_p1rlv143_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "46cd88d0-b2c4-492a-af3d-d9ae886d0089"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b5c00744-639c-41ea-96ca-c1f09800fc3a"}}}}, {"uuid": "6efba862-2084-4197-8842-7a4e3e7cbe55", "name": "ca51752d-e464-48b4-89bb-3cab4889764a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9024769844937937, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4778358547008617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4618b6bb-3217-4c40-81e5-337da883d284", "name": "d6d818ce-0039-4dc7-92b2-95d506c66f3d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6efba862-2084-4197-8842-7a4e3e7cbe55"}}}]}, {"uuid": "6dfbe3aa-d122-4dd0-adae-a501ba9ce94f", "name": "load_p1rlv144_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b7dbf54-f6bc-4e20-b2f3-8c63a44dd993"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4618b6bb-3217-4c40-81e5-337da883d284"}}}}, {"uuid": "9b3d7385-18b7-4c12-87d4-28509ac71622", "name": "8b41385c-d319-435b-878e-1abaaf86169d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9024769844937937, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4778358547008617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cfddae17-0b75-403e-8c4b-abf94636a6da", "name": "bd484a3e-574e-4959-9058-98b297b870ba", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9b3d7385-18b7-4c12-87d4-28509ac71622"}}}]}, {"uuid": "651d58ec-8f41-4a45-87bf-325c1f4cd4ab", "name": "load_p1rlv144_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b7dbf54-f6bc-4e20-b2f3-8c63a44dd993"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cfddae17-0b75-403e-8c4b-abf94636a6da"}}}}, {"uuid": "596e3b96-2e23-4f01-90df-cd04c0f0f94c", "name": "a681cdc9-4b50-46b7-8c08-2d8bffbb7144_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5478654763148745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5646840796232575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "64174510-2d82-4a24-91df-ec21ad651c75", "name": "94f59b95-5d40-449e-982f-797659492681", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "596e3b96-2e23-4f01-90df-cd04c0f0f94c"}}}]}, {"uuid": "2c8ea63a-1b5f-4324-8f57-3190d9421025", "name": "load_p1rlv145_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1704e67-dfa3-4a6b-a3f4-7ebba9d27537"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "64174510-2d82-4a24-91df-ec21ad651c75"}}}}, {"uuid": "26401bca-ca42-4b35-96cb-c083a9c82b1e", "name": "40b6c346-3a2f-4b29-a7b6-747e501f9941_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5478654763148745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5646840796232575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c752fc03-cc98-431f-bdef-07b64f2c5114", "name": "7fd9d5e3-d134-4162-8ad5-5b57c4b8eb78", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "26401bca-ca42-4b35-96cb-c083a9c82b1e"}}}]}, {"uuid": "033e9386-a8ca-41a0-b92b-a0e2abb19756", "name": "load_p1rlv145_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1704e67-dfa3-4a6b-a3f4-7ebba9d27537"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c752fc03-cc98-431f-bdef-07b64f2c5114"}}}}, {"uuid": "b304661b-8f12-449a-8f41-f02a8a8c80e2", "name": "9e58965c-d189-4f80-86fe-7f5fb1bf3fcf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8309189378455104, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6069744647018672, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a64c60f-711f-4c47-ad03-c64950c901a1", "name": "2e28f36a-4df6-4074-806a-a131dde98fd9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b304661b-8f12-449a-8f41-f02a8a8c80e2"}}}]}, {"uuid": "b2e7ecf7-0e4c-444d-8662-2650fcbbdf78", "name": "load_p1rlv146_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da2538bd-189b-4699-823b-ed459d94b422"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a64c60f-711f-4c47-ad03-c64950c901a1"}}}}, {"uuid": "c0bafccd-dcf8-4967-8689-6d2494d0b36c", "name": "2c66c959-d921-48eb-b2fe-7f3c076980f0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8309189378455104, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6069744647018672, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6fdf8d05-e64c-493f-945d-164885fb3387", "name": "fd78a750-5fc4-431b-bf2f-b6cdba25cfd6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c0bafccd-dcf8-4967-8689-6d2494d0b36c"}}}]}, {"uuid": "23482389-4769-43fa-8b5f-093a6f1dbc66", "name": "load_p1rlv146_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da2538bd-189b-4699-823b-ed459d94b422"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6fdf8d05-e64c-493f-945d-164885fb3387"}}}}, {"uuid": "d96d1306-0ca2-444f-bd3a-14e7ce69c39c", "name": "79ef7648-0e4f-47f3-9552-070c1daf8b7e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.3355603190645935, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9435041304985261, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4e188817-c68e-43ff-b1b3-d8b89b6313f8", "name": "2e1300a2-b142-4cf7-b428-44ae641f3b33", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d96d1306-0ca2-444f-bd3a-14e7ce69c39c"}}}]}, {"uuid": "44fd75f0-0108-48e9-91b3-66e8bd787b59", "name": "load_p1rlv147_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "070d9a60-c6f2-424c-bd0f-66c52d349f0c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4e188817-c68e-43ff-b1b3-d8b89b6313f8"}}}}, {"uuid": "4f99e19b-0c10-4aa1-a8d2-49724a8051ad", "name": "6d8d7835-2274-4924-9a05-990a5b79ed12_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.3355603190645935, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9435041304985261, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "56054ae6-3682-47ac-a664-23bb779230da", "name": "2dbd413d-f2d8-468d-9705-7dd87674f442", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4f99e19b-0c10-4aa1-a8d2-49724a8051ad"}}}]}, {"uuid": "bcbb05e5-afc4-4792-87d5-52bea1b4b377", "name": "load_p1rlv147_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "070d9a60-c6f2-424c-bd0f-66c52d349f0c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "56054ae6-3682-47ac-a664-23bb779230da"}}}}, {"uuid": "58883f3e-fe3f-4f4a-b34b-a98fbc741f50", "name": "f46cb48f-eaaa-4ffb-9352-6dc4011d0fbb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8322096344455547, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7991596594888891, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "467b71c4-89b2-41bb-a169-4113dd36049d", "name": "2f7cc6c9-2406-41b0-a256-0bf75d1c8276", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58883f3e-fe3f-4f4a-b34b-a98fbc741f50"}}}]}, {"uuid": "6592f31a-023d-4bb6-bff2-43300edf4703", "name": "load_p1rlv148_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa8af0a4-4d55-41e4-83d1-4fe349920e38"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "467b71c4-89b2-41bb-a169-4113dd36049d"}}}}, {"uuid": "f3b31322-4a81-4bd1-81b9-bcc2afe6fdf5", "name": "4dffbdd2-5c5c-4770-bd8d-35347cb4a8c6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8322096344455547, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7991596594888891, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b2180f75-44f0-42d8-88f3-f1346b5158b9", "name": "abba6f94-a44b-4def-8331-63b5e15689d0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f3b31322-4a81-4bd1-81b9-bcc2afe6fdf5"}}}]}, {"uuid": "222251ff-23fc-4c53-b67b-5d791152038f", "name": "load_p1rlv148_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa8af0a4-4d55-41e4-83d1-4fe349920e38"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b2180f75-44f0-42d8-88f3-f1346b5158b9"}}}}, {"uuid": "b18a0e35-3710-4ac6-8659-b140bcddb054", "name": "0f329b93-21bb-46c9-81b6-04efa26cb4d7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4856814769108864, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8267323554826451, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c299fdab-1be2-44cc-96e2-6818b024cf1a", "name": "7a46dd14-b0c7-4773-90e5-a77125b014aa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b18a0e35-3710-4ac6-8659-b140bcddb054"}}}]}, {"uuid": "7d8e659d-c80b-4311-97a0-4bccb4c72934", "name": "load_p1rlv149_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "063e89ea-6dd0-404f-abfb-21686f3041ed"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c299fdab-1be2-44cc-96e2-6818b024cf1a"}}}}, {"uuid": "d9f6edac-f43c-41d2-9855-3e5d321a5557", "name": "c29d21b1-bfc1-401b-98a6-fdb5f43c054f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4856814769108864, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8267323554826451, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c7ac34c1-7a2f-4670-8fc2-8f72b68d431a", "name": "be672881-04e7-4295-b56d-1fd88d691219", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d9f6edac-f43c-41d2-9855-3e5d321a5557"}}}]}, {"uuid": "9b6cbfe0-93bd-470e-a7c2-b85265e317a0", "name": "load_p1rlv149_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "063e89ea-6dd0-404f-abfb-21686f3041ed"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c7ac34c1-7a2f-4670-8fc2-8f72b68d431a"}}}}, {"uuid": "2755d3e5-9a94-44af-9a22-f04a395f82bd", "name": "77049928-0e3f-4ffa-a8eb-edc8a66ec445_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4363904318707768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7717292253609904, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6bf52870-b994-4ac6-a78e-f09d89990a8e", "name": "7d6ae7c1-3b27-41a7-bd5b-17fbd7f49a36", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2755d3e5-9a94-44af-9a22-f04a395f82bd"}}}]}, {"uuid": "c9162abe-7b46-4442-b723-313a2f140b94", "name": "load_p1rlv150_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b9979ec-4e43-4feb-a617-28191e9dd9d8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6bf52870-b994-4ac6-a78e-f09d89990a8e"}}}}, {"uuid": "cc94c4fb-e6d2-4258-99f2-80cc480e81f8", "name": "56adb619-83e9-403c-b508-c29461a2acdf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4363904318707768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7717292253609904, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "923dac6e-dac9-4b6a-88b9-f90ce0af4d15", "name": "12e1cf39-01d8-4998-9719-5ff883dbd7c5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cc94c4fb-e6d2-4258-99f2-80cc480e81f8"}}}]}, {"uuid": "38d8ebb4-802c-4053-9ffc-dad485aa76c3", "name": "load_p1rlv150_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b9979ec-4e43-4feb-a617-28191e9dd9d8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "923dac6e-dac9-4b6a-88b9-f90ce0af4d15"}}}}, {"uuid": "4a96dd5c-c1cf-4bda-8faa-6c177cac16a0", "name": "6cdc4319-9a33-4da3-a140-3084bd8675d2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.371919551924291, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7891526087442801, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e6169458-cf82-4d24-9754-3f8c1bd6a7fc", "name": "045e2802-f6e2-4e20-8056-bdb6b7c4142f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4a96dd5c-c1cf-4bda-8faa-6c177cac16a0"}}}]}, {"uuid": "0cda9978-67ba-4878-a11b-9c6683e1b644", "name": "load_p1rlv151_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "345b5c48-cd35-418e-bc08-50c06f5dff09"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e6169458-cf82-4d24-9754-3f8c1bd6a7fc"}}}}, {"uuid": "fd0d566a-eb29-49c1-b499-db0fef89ceeb", "name": "410cbe2a-d7b3-412a-b5a5-1d5e77cbc28c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.371919551924291, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7891526087442801, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "24d62fae-b96b-411a-a99a-e92cb4e74a46", "name": "bb1f18f6-0cad-4534-b8bd-2d97729aef38", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fd0d566a-eb29-49c1-b499-db0fef89ceeb"}}}]}, {"uuid": "43d28bc8-e7f1-4742-8311-292f1796ff7c", "name": "load_p1rlv151_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "345b5c48-cd35-418e-bc08-50c06f5dff09"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "24d62fae-b96b-411a-a99a-e92cb4e74a46"}}}}, {"uuid": "bb9f90a6-0e2c-480b-abaf-2caaf59df40d", "name": "b55ad8a0-3c28-4dad-be50-b52c8aad5aef_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1381537134701794, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42848704523913217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6aa1373f-1958-42b9-8eb0-2aa8619f5abb", "name": "96966198-f951-452f-9a42-229b7fd330b1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bb9f90a6-0e2c-480b-abaf-2caaf59df40d"}}}]}, {"uuid": "1a727775-9d19-408b-aa4a-28ef8bac6e71", "name": "load_p1rlv152_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25b891ce-797a-4a4d-b664-4225fba806c4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6aa1373f-1958-42b9-8eb0-2aa8619f5abb"}}}}, {"uuid": "50d91c7a-0fab-42dd-9308-c8d005ab6688", "name": "351c5236-9e35-4471-833c-dc9da4e7e306_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1381537134701794, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42848704523913217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4cb66431-8190-4793-9e90-23f1cdb1cb25", "name": "7f716e77-1e2b-4a56-95cb-dc1a96d25136", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "50d91c7a-0fab-42dd-9308-c8d005ab6688"}}}]}, {"uuid": "21fe823b-b24d-4c2c-a164-eb7bf5f9c199", "name": "load_p1rlv152_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25b891ce-797a-4a4d-b664-4225fba806c4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4cb66431-8190-4793-9e90-23f1cdb1cb25"}}}}, {"uuid": "ad038307-bf63-4325-aaf3-7073f33fc11c", "name": "41412b4d-fb58-44a6-af9d-eac87b314ace_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.567401274738218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6497123013243786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9589c15d-3d6c-4085-a001-b653159fda79", "name": "a02eb120-8919-40e8-9966-15fa07f620d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ad038307-bf63-4325-aaf3-7073f33fc11c"}}}]}, {"uuid": "3ad36ef3-8756-4f87-937c-8b411a17f018", "name": "load_p1rlv153_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ebbe09dd-7560-4eff-9e32-803f14b4ce7c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9589c15d-3d6c-4085-a001-b653159fda79"}}}}, {"uuid": "3d6b9794-cc04-4a3c-8508-8c264e5770c7", "name": "b1908562-73cc-4fb3-aad9-109c6f7b8693_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.567401274738218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6497123013243786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "28f9d670-2046-4464-aebf-afde5cb96ba4", "name": "c59fabc3-bbb0-4ff5-99d0-a1e491b30a5e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3d6b9794-cc04-4a3c-8508-8c264e5770c7"}}}]}, {"uuid": "88e1d099-0fe2-4cf9-9696-2cd72fa5929d", "name": "load_p1rlv153_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ebbe09dd-7560-4eff-9e32-803f14b4ce7c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "28f9d670-2046-4464-aebf-afde5cb96ba4"}}}}, {"uuid": "ff01f4eb-995f-4752-b365-bba2b9223d49", "name": "4dc3d221-3521-416a-b5e5-46ff24f0c3e1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6235247805381197, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5206515777483778, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "47d88b93-6ce7-4903-bac2-9c34abcdfe9e", "name": "de3bf5d6-9721-4ffb-96a8-2dde7c116d90", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ff01f4eb-995f-4752-b365-bba2b9223d49"}}}]}, {"uuid": "fe71efd1-7d64-4c4a-ac74-446d584f4c5e", "name": "load_p1rlv154_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ccdfbc7-d3a6-4f74-ad32-25ff11a2e3b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "47d88b93-6ce7-4903-bac2-9c34abcdfe9e"}}}}, {"uuid": "0614c34a-114c-40d2-a8c2-2d1a046eeed4", "name": "99ae88cc-c8fe-4c25-9c77-2dbe4f065ce2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6235247805381197, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5206515777483778, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "addce10f-e9ee-486f-b31b-e941253493a8", "name": "b453f214-b5c5-42a8-837e-0a729f59b610", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0614c34a-114c-40d2-a8c2-2d1a046eeed4"}}}]}, {"uuid": "8c98171c-35a4-4280-bc3b-6e54c2785507", "name": "load_p1rlv154_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ccdfbc7-d3a6-4f74-ad32-25ff11a2e3b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "addce10f-e9ee-486f-b31b-e941253493a8"}}}}, {"uuid": "5fd7bfc3-e074-4c73-af9b-c9afd6066292", "name": "551775ff-9f39-42b0-830d-e330ac2d1791_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.108706484347092, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9298438232381894, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f6a57a7d-a667-482a-be6f-e450371abb29", "name": "aeea7305-281e-4470-af56-a22592c1c7ff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5fd7bfc3-e074-4c73-af9b-c9afd6066292"}}}]}, {"uuid": "18f9ee3a-9c84-4710-beab-a5bb978ec532", "name": "load_p1rlv155_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2452d5af-5aba-4d4b-8cd9-27a95fe6b34d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f6a57a7d-a667-482a-be6f-e450371abb29"}}}}, {"uuid": "3a47ae95-d7cb-4523-93c2-230fb065d89b", "name": "c95d57ba-4cf0-4346-bd63-3f17baf8f9cb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.108706484347092, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9298438232381894, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e6a822a7-b8d1-4bb4-9a75-ab11afaa184f", "name": "d725a57f-a94b-41c7-a169-d697f57dadb1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3a47ae95-d7cb-4523-93c2-230fb065d89b"}}}]}, {"uuid": "8e9ded2b-34fc-4efa-8c3c-dca36a27429a", "name": "load_p1rlv155_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2452d5af-5aba-4d4b-8cd9-27a95fe6b34d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e6a822a7-b8d1-4bb4-9a75-ab11afaa184f"}}}}, {"uuid": "948fd41c-89a2-42c7-af9e-4063c6d0b180", "name": "fc5973c9-b174-43c4-8cdf-7a83995d7b04_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7537427041030689, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.37349948863112625, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "abf8107a-a30b-4316-a765-541a893ce591", "name": "c1c669b4-f5a0-43c9-968d-302e6cb121e3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "948fd41c-89a2-42c7-af9e-4063c6d0b180"}}}]}, {"uuid": "5d8cfb02-36f5-4d97-980b-1c7bedf17ccf", "name": "load_p1rlv156_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f607e6b-9540-4845-9f0c-6c334eb0e807"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "abf8107a-a30b-4316-a765-541a893ce591"}}}}, {"uuid": "935ef1c3-72e1-436e-bc15-f545f6b403df", "name": "5191cadc-6d3e-48d3-8e78-1380f62e6742_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7537427041030689, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.37349948863112625, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82073bd9-631c-47e5-9919-c1b48349e72d", "name": "469bcafc-5ecb-4cc8-890e-900f450020c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "935ef1c3-72e1-436e-bc15-f545f6b403df"}}}]}, {"uuid": "9db2b8c0-d340-498e-859f-41389b498e69", "name": "load_p1rlv156_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f607e6b-9540-4845-9f0c-6c334eb0e807"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "82073bd9-631c-47e5-9919-c1b48349e72d"}}}}, {"uuid": "bbb9af72-1b21-4719-acda-ff7ca257537b", "name": "fdb83a04-3f11-4a69-8f2d-ca418085afcd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.095937077188644, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9158391685680531, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10e19920-3702-415e-83da-bc6eb9517f3d", "name": "78eb2ff1-0b89-4b2a-85b9-3fe469d614d9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bbb9af72-1b21-4719-acda-ff7ca257537b"}}}]}, {"uuid": "5f7c3981-32f3-4b90-bed6-25b9d01fc927", "name": "load_p1rlv157_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4355a473-4643-4f72-afe8-80ce773ca8e8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10e19920-3702-415e-83da-bc6eb9517f3d"}}}}, {"uuid": "175e92fa-a479-4df5-b9c0-237f7d031d69", "name": "3d0ce575-376f-4ba3-a146-4f3a1499a5e3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.095937077188644, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9158391685680531, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7a5f84b4-faf1-4cf8-8940-65f8f657c018", "name": "2c3d94ef-3441-4046-9dc3-92fa55fe52a1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "175e92fa-a479-4df5-b9c0-237f7d031d69"}}}]}, {"uuid": "fbe3ca78-571d-4ae4-860f-991921cbbcaf", "name": "load_p1rlv157_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4355a473-4643-4f72-afe8-80ce773ca8e8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7a5f84b4-faf1-4cf8-8940-65f8f657c018"}}}}, {"uuid": "8cdd07ea-28f2-4a13-9de0-e26993ff5341", "name": "4ee96c19-3806-4064-94b6-eeb44c18e551_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8840297592093247, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9532534150802011, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "899d4299-2a0e-4ae5-b0b9-1390e0fcc535", "name": "d78e16a0-bffa-49d7-ac9b-8b36e97e82d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8cdd07ea-28f2-4a13-9de0-e26993ff5341"}}}]}, {"uuid": "8de3c047-03a9-4aba-9e64-f6ab42a642a6", "name": "load_p1rlv158_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1cd7284-17fb-4382-a29d-dd8c5bfd7541"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "899d4299-2a0e-4ae5-b0b9-1390e0fcc535"}}}}, {"uuid": "0c8d86db-65a9-4c7d-af73-c853594251e4", "name": "3eb1bae5-9be0-415d-844d-fc6a79d0ac7e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8840297592093247, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9532534150802011, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "778bb6f1-53ee-4071-b98f-50c7a63b20a1", "name": "4146d0a9-becf-474c-90ce-ea5b8fc8844e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0c8d86db-65a9-4c7d-af73-c853594251e4"}}}]}, {"uuid": "e41e26d9-4dcc-4f50-ac1a-dc1a9f2fdeed", "name": "load_p1rlv158_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1cd7284-17fb-4382-a29d-dd8c5bfd7541"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "778bb6f1-53ee-4071-b98f-50c7a63b20a1"}}}}, {"uuid": "d68b2e1c-0cbf-46c4-913b-f7d400006ae7", "name": "9f845cf9-8a36-4ec0-bba1-3983a908f7e8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.374654272561421, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4772638197977597, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e6f5f0bb-c625-4ae5-80f5-ea8be9ed6188", "name": "27cc8d66-ef3e-4ce0-bd01-0b412d29c7b7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d68b2e1c-0cbf-46c4-913b-f7d400006ae7"}}}]}, {"uuid": "83135160-8d59-48d8-89f3-a13a2e5a666d", "name": "load_p1rlv159_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0ae6c02-c29e-4bf9-b1d4-ecc7e37e7de2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e6f5f0bb-c625-4ae5-80f5-ea8be9ed6188"}}}}, {"uuid": "3cfea8c2-b638-47d9-b2ac-ef32e676f050", "name": "1b8759f5-240f-4f14-bb73-b120b24050f6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.374654272561421, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4772638197977597, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c5d16f5c-a56f-4d89-9ba4-0e87a25ae1e4", "name": "9632e604-abee-4381-a8da-ef8a40bb3c5d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3cfea8c2-b638-47d9-b2ac-ef32e676f050"}}}]}, {"uuid": "3c29eda9-ab0f-4b5b-998f-68e75fdc6376", "name": "load_p1rlv159_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0ae6c02-c29e-4bf9-b1d4-ecc7e37e7de2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c5d16f5c-a56f-4d89-9ba4-0e87a25ae1e4"}}}}, {"uuid": "b9ddc7cb-eb34-46b9-8a35-4504b55c290c", "name": "7428b4e2-67cc-42de-88ea-cbee112a2d17_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.442421826038779, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9571745396829384, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6c0b14c3-394b-4868-b1d3-5d7e95265052", "name": "bb27f7e2-8d35-46f2-a528-59ef9a686b87", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b9ddc7cb-eb34-46b9-8a35-4504b55c290c"}}}]}, {"uuid": "f9560b22-0982-4d00-8b31-a029346a264e", "name": "load_p1rlv160_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd2fae5a-e5dd-4ad4-8acc-422de00ae83e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6c0b14c3-394b-4868-b1d3-5d7e95265052"}}}}, {"uuid": "af343575-9b10-43f2-9a7b-35f179fb9685", "name": "2970a6c2-819e-455d-a867-daa7338e6234_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.442421826038779, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9571745396829384, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c5f5f382-7b6d-4bae-a150-b970b5ee303f", "name": "ea134b02-0b2f-4a4f-be02-7a0cd5401977", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "af343575-9b10-43f2-9a7b-35f179fb9685"}}}]}, {"uuid": "8133c7b7-4525-4ca0-a609-363f6efc7d54", "name": "load_p1rlv160_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd2fae5a-e5dd-4ad4-8acc-422de00ae83e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c5f5f382-7b6d-4bae-a150-b970b5ee303f"}}}}, {"uuid": "328d8c3e-0611-4a1e-b691-dc74728b29c5", "name": "af682978-efe2-47c9-a254-c3c11fc0d851_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0ff97ff9-a544-4896-8d12-a2f3de1ce723", "name": "589c8a5d-0a70-4a9c-9b5b-8a80a9d0e905", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "328d8c3e-0611-4a1e-b691-dc74728b29c5"}}}]}, {"uuid": "0628e2d9-5b47-44ae-87b3-22c5f8b928e3", "name": "load_p1rlv161_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4842819e-3f17-47da-a8bf-c3402c3c00b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0ff97ff9-a544-4896-8d12-a2f3de1ce723"}}}}, {"uuid": "8a242f35-2441-445f-8acf-0276263fed46", "name": "25040100-e180-4f0b-8556-982cff6f28b8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bfc0ef6d-9d70-45f9-b448-da730be6008c", "name": "195665b6-661d-4ba2-b416-f11523a8957c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a242f35-2441-445f-8acf-0276263fed46"}}}]}, {"uuid": "9f3ac376-58ea-4e67-860a-22cb60ee101b", "name": "load_p1rlv161_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4842819e-3f17-47da-a8bf-c3402c3c00b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bfc0ef6d-9d70-45f9-b448-da730be6008c"}}}}, {"uuid": "0c866a74-80b4-4de8-ab0f-8af6d5e99cc7", "name": "0d2de203-31e0-414e-86dd-b5ecdf23e2ed_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8374792851175116, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3203908676737591, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2dd7a99d-e8de-47c1-9d13-4bf7dd8f3b77", "name": "9df39120-b9c3-4747-bddc-d26981985449", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0c866a74-80b4-4de8-ab0f-8af6d5e99cc7"}}}]}, {"uuid": "cdccd113-7867-400e-9bfc-673b6504e025", "name": "load_p1rlv162_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3fcd1ee-e6e0-4ca3-aacf-cc527b07482a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2dd7a99d-e8de-47c1-9d13-4bf7dd8f3b77"}}}}, {"uuid": "d2422cd1-af9d-45dc-8c9c-7288cfc5a26b", "name": "bde66f82-50c0-41b3-b680-4d7bddd49d6e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8374792851175116, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3203908676737591, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0f1052fb-c159-459d-bf3e-737a269fb736", "name": "d2e1b2a4-fcf6-4c91-a810-c2e59000da86", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d2422cd1-af9d-45dc-8c9c-7288cfc5a26b"}}}]}, {"uuid": "b329cd69-c9b0-4878-ac79-27870fdbbe7e", "name": "load_p1rlv162_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3fcd1ee-e6e0-4ca3-aacf-cc527b07482a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0f1052fb-c159-459d-bf3e-737a269fb736"}}}}, {"uuid": "96517525-e2c4-4d6d-aa67-3c78f0ede687", "name": "6c840f55-ebfd-43cc-9769-381ffbf540d5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.255903801273714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9789336651099453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f698c194-b969-456c-9959-4ebbdb8258f3", "name": "98aae7db-d220-421a-acee-cdddcf98741b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "96517525-e2c4-4d6d-aa67-3c78f0ede687"}}}]}, {"uuid": "008c43f1-f5ea-44de-b929-426e8ea6a8ac", "name": "load_p1rlv163_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "471bad88-4514-4b02-aa1a-1d2aaa15557f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f698c194-b969-456c-9959-4ebbdb8258f3"}}}}, {"uuid": "156e6d01-cde8-4bc7-a0cc-ba85375c0343", "name": "0dd99461-0697-4bf2-90a3-f24b43c866bf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.255903801273714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9789336651099453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10d3b8af-7878-4ddd-a72f-04d0d6d5de38", "name": "9fe24db1-0e1e-490c-8da4-76b48f4d9ed3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "156e6d01-cde8-4bc7-a0cc-ba85375c0343"}}}]}, {"uuid": "b5ba124b-48a8-4202-9869-3c0a2845cefa", "name": "load_p1rlv163_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "471bad88-4514-4b02-aa1a-1d2aaa15557f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10d3b8af-7878-4ddd-a72f-04d0d6d5de38"}}}}, {"uuid": "ae092096-ac18-4e26-8ec9-767664b6f311", "name": "469ae3f3-b681-4f98-a225-2dfd2453a804_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.634023352191214, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2934174607236286, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "11d28751-2dc2-4643-ade5-056105ccf36c", "name": "0b58701e-29db-4654-93f6-13763353b25f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ae092096-ac18-4e26-8ec9-767664b6f311"}}}]}, {"uuid": "b4e237d5-30ca-442d-8332-301533b55a01", "name": "load_p1rlv164_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61460072-bdc5-4a70-96fa-8ecfa71623f4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "11d28751-2dc2-4643-ade5-056105ccf36c"}}}}, {"uuid": "b59962b8-410d-4873-8558-4dbe02ecb8fe", "name": "a0671619-9046-42c9-b892-98a56904909a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.634023352191214, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2934174607236286, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dc46ae19-b1eb-4477-87fb-ee2ba7499455", "name": "154e2be4-cb1f-478b-9e94-8f93b38d66c4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b59962b8-410d-4873-8558-4dbe02ecb8fe"}}}]}, {"uuid": "1b646ba1-bbb4-4502-b283-b240fdd81ce4", "name": "load_p1rlv164_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61460072-bdc5-4a70-96fa-8ecfa71623f4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dc46ae19-b1eb-4477-87fb-ee2ba7499455"}}}}, {"uuid": "bb4fa101-0970-45f9-a5db-ebad81aacb1c", "name": "8361d8ec-a547-4a5a-8787-e617c97ed8fb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.916354724025409, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9016755043678467, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3f4de5dd-749e-4e87-909a-e035a519fcdd", "name": "cc92d500-45e7-42e1-ae9b-13d8bb2f2fff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bb4fa101-0970-45f9-a5db-ebad81aacb1c"}}}]}, {"uuid": "0b35ffa2-4fa3-4ab2-84fa-08aaa61760c4", "name": "load_p1rlv165_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e7880c9-0932-4395-abf9-2274e400f280"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3f4de5dd-749e-4e87-909a-e035a519fcdd"}}}}, {"uuid": "d3f6d1d9-b892-4800-b2a5-7dad65648d40", "name": "96e6e68a-0043-4f91-9a2a-5b6b8b9aa970_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.916354724025409, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9016755043678467, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1d03c60f-63b8-4b5a-baba-e7e71a7e9690", "name": "ce24492e-0581-4b7b-918c-0c97ae277ba3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d3f6d1d9-b892-4800-b2a5-7dad65648d40"}}}]}, {"uuid": "468330c1-1a98-49d0-9b35-871faab87fbc", "name": "load_p1rlv165_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e7880c9-0932-4395-abf9-2274e400f280"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1d03c60f-63b8-4b5a-baba-e7e71a7e9690"}}}}, {"uuid": "768dc0db-9dfb-47b2-aac9-7217b1b0cbee", "name": "dc3081f4-2919-49bb-96a1-2f070a62ebc3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0137187800791063, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5284248988065299, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d9c6e84e-8f73-401c-88e7-e518034cdd97", "name": "4934d0b2-27f2-4f83-a544-8afa0eb732ae", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "768dc0db-9dfb-47b2-aac9-7217b1b0cbee"}}}]}, {"uuid": "0c371311-d835-4725-93c2-38caf4340198", "name": "load_p1rlv166_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21d333f7-7426-4fa6-8ab2-c6118055ece1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d9c6e84e-8f73-401c-88e7-e518034cdd97"}}}}, {"uuid": "085d4979-f0e8-4a81-b766-4edceb93e79e", "name": "bf77bda4-8aa9-4eba-89dd-84980b634d82_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0137187800791063, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5284248988065299, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b0114f8e-42b3-4cf6-bf82-0b5a74d34435", "name": "585e8691-2f0c-4b61-84c7-c44b11f02892", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "085d4979-f0e8-4a81-b766-4edceb93e79e"}}}]}, {"uuid": "4842b8c9-483a-4000-b8e4-e92115d3362f", "name": "load_p1rlv166_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21d333f7-7426-4fa6-8ab2-c6118055ece1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b0114f8e-42b3-4cf6-bf82-0b5a74d34435"}}}}, {"uuid": "e3d3f347-2cc5-4163-b195-f4feba41a7fd", "name": "76df4f4c-e521-4730-8e19-8b809222dc22_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.438316346451239, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6915244213249778, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bad3c5a9-944e-4467-ae32-a39f8d2467de", "name": "98d01b2b-b1f1-4250-9f1d-41f70ff5d409", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e3d3f347-2cc5-4163-b195-f4feba41a7fd"}}}]}, {"uuid": "edf53ba9-4c8d-48d7-8acc-70d10e07dd76", "name": "load_p1rlv167_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5187e006-621e-4c15-9604-0272ae62887c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bad3c5a9-944e-4467-ae32-a39f8d2467de"}}}}, {"uuid": "f4199876-e02c-443b-8a34-a7b5569f45be", "name": "52482e87-111f-48b8-acd8-e110e76daa7d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.438316346451239, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6915244213249778, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "549f4461-fd8e-4e37-b9ef-b0d574c9ce4d", "name": "793f7997-5e15-45b1-9c9c-14738a369d89", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f4199876-e02c-443b-8a34-a7b5569f45be"}}}]}, {"uuid": "c9d4f26a-59c2-47b0-82c3-cad585ad2f67", "name": "load_p1rlv167_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5187e006-621e-4c15-9604-0272ae62887c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "549f4461-fd8e-4e37-b9ef-b0d574c9ce4d"}}}}, {"uuid": "8214ae9e-a98a-47c7-bf7a-310a375c354b", "name": "d0eb3fa8-a282-44f2-8e59-84f3c3ccbabd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.639612501586281, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0977377571892493, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6742fd24-2bc0-431d-b30d-4dc763353622", "name": "ef806c3e-41af-4e54-9db4-fd35effb1c39", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8214ae9e-a98a-47c7-bf7a-310a375c354b"}}}]}, {"uuid": "9cf5e44e-7289-461c-87bd-47979c4da230", "name": "load_p1rlv168_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "470fe3ed-5b24-438a-ba6d-cdd9f774e5ad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6742fd24-2bc0-431d-b30d-4dc763353622"}}}}, {"uuid": "3cb772b7-4657-4d8c-b525-85caf30002e2", "name": "166a84a5-46bf-463f-a30d-ac639c12ef84_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.639612501586281, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0977377571892493, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1a1b7a21-7a66-4d44-a8a0-09649c122699", "name": "3cef0015-9633-4bbc-97cd-151780b2104d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3cb772b7-4657-4d8c-b525-85caf30002e2"}}}]}, {"uuid": "6cab2d7f-7acf-4f13-a544-9b4d10e51b6e", "name": "load_p1rlv168_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "470fe3ed-5b24-438a-ba6d-cdd9f774e5ad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1a1b7a21-7a66-4d44-a8a0-09649c122699"}}}}, {"uuid": "383399fd-31e7-4be4-99a8-6525097749ec", "name": "43b935d3-1a10-4adf-9410-46944594ccb7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.684904254134122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42635901069761617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f44b0661-5eed-4671-8837-51e4c5c01de3", "name": "d59b11a3-8cb6-49c5-95c5-60f8d1118f4b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "383399fd-31e7-4be4-99a8-6525097749ec"}}}]}, {"uuid": "1fd860c2-0753-45b8-baa9-3dc334d13763", "name": "load_p1rlv169_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e326756-7ead-4099-a065-9f2de5693197"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f44b0661-5eed-4671-8837-51e4c5c01de3"}}}}, {"uuid": "eeae9ebe-ad30-4b1e-b628-12e620aa68ec", "name": "3718c088-26e2-46ec-8ae8-2a1e26017e5f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.684904254134122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42635901069761617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fb2e612d-b1e6-4bc5-984a-fa6fe8fb9df5", "name": "2772f810-9754-4bd1-9c53-5e888bfd626a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eeae9ebe-ad30-4b1e-b628-12e620aa68ec"}}}]}, {"uuid": "9dc019fb-8428-44bd-a4e0-82641341dbcd", "name": "load_p1rlv169_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e326756-7ead-4099-a065-9f2de5693197"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fb2e612d-b1e6-4bc5-984a-fa6fe8fb9df5"}}}}, {"uuid": "1bd5db0e-8d36-4d2c-b7c0-993a45f5424c", "name": "c90b3a0a-1417-4e01-974d-e7498f6e4231_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7812856221781264, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.29493523962554685, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c16e7813-54ab-4d3e-b29f-e5b94c25edef", "name": "91b96749-f6a7-4aaa-8ef1-27ee7f1d7098", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1bd5db0e-8d36-4d2c-b7c0-993a45f5424c"}}}]}, {"uuid": "4b2fd52a-2379-40cc-b0e7-5233f221bf47", "name": "load_p1rlv170_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f7dbd18-1cbe-49d3-b490-3c46cf8e37f1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c16e7813-54ab-4d3e-b29f-e5b94c25edef"}}}}, {"uuid": "59335f20-1ff3-4163-8844-d0bccb5c1dd8", "name": "fd8c620e-38b3-4a2f-8207-a0ec2ba4c534_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7812856221781264, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.29493523962554685, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c7a14033-b9a3-4231-8824-61308ee49db0", "name": "ed26bab6-3b3c-4663-8439-73d41ffca540", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "59335f20-1ff3-4163-8844-d0bccb5c1dd8"}}}]}, {"uuid": "0b0521c1-45dd-4a1f-8d44-d93a0eaf0b10", "name": "load_p1rlv170_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f7dbd18-1cbe-49d3-b490-3c46cf8e37f1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c7a14033-b9a3-4231-8824-61308ee49db0"}}}}, {"uuid": "86845da4-bb7d-4900-9c00-c6be83efd8ca", "name": "a6904d60-3eda-4ac0-9945-67a01bc5e6d7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7997673490012955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.772957044307952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f8da8d9c-2705-4d59-9e4a-99d23673be05", "name": "b389c1ff-fe5b-4cb8-8253-5b50ddf92ea7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "86845da4-bb7d-4900-9c00-c6be83efd8ca"}}}]}, {"uuid": "b861f8df-f309-4edb-a49e-5abbc43f7496", "name": "load_p1rlv174_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1186295-59ff-48a8-b31d-0f7cd40df1ab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f8da8d9c-2705-4d59-9e4a-99d23673be05"}}}}, {"uuid": "6cada501-95eb-4758-ae39-fe53048531d5", "name": "27711f95-8460-40c6-9724-4f27c75fc0eb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7997673490012955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.772957044307952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7d080bb8-d0ae-4e18-a50e-af67f4a22adb", "name": "38120dbf-2229-4a03-a721-2a227cae7ab8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6cada501-95eb-4758-ae39-fe53048531d5"}}}]}, {"uuid": "5ef0ca22-9b94-4e1c-87b4-ce7fb335b3f8", "name": "load_p1rlv174_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1186295-59ff-48a8-b31d-0f7cd40df1ab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7d080bb8-d0ae-4e18-a50e-af67f4a22adb"}}}}, {"uuid": "32d09fa6-77c4-4c1b-bb61-807cfc09ff43", "name": "c480aefe-44ba-44d6-9062-01b0ef9fd938_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2562100051220524, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.06533962175647968, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e648a41d-31dd-415d-a78b-6f023dfdd28d", "name": "a2b00fbb-9868-459e-91e2-464d724fbbb0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "32d09fa6-77c4-4c1b-bb61-807cfc09ff43"}}}]}, {"uuid": "13593603-abcb-4843-9994-1637c6b41373", "name": "load_p1rlv175_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905e9287-bdb6-44e0-b0af-f59ab4ad4d8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e648a41d-31dd-415d-a78b-6f023dfdd28d"}}}}, {"uuid": "93daaec5-a80d-4c09-a45c-c9e4efe1553c", "name": "4d0e3ca5-98a1-478f-99f3-4c2abe4fecec_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2562100051220524, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.06533962175647968, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "912c8def-e8ae-4a1e-9ad7-0e603c08a529", "name": "4f5b5bcc-a092-48a9-8a4b-19eb8dbf520b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "93daaec5-a80d-4c09-a45c-c9e4efe1553c"}}}]}, {"uuid": "a64c2d9e-7189-4d59-a635-5f3fea3d070e", "name": "load_p1rlv175_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905e9287-bdb6-44e0-b0af-f59ab4ad4d8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "912c8def-e8ae-4a1e-9ad7-0e603c08a529"}}}}, {"uuid": "698bdf1b-1257-4c31-85f8-bacacde1eb47", "name": "babffe7a-fa6f-40a4-a3d7-450c5fbb1531_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6697995975485909, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.41657408993223344, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "407f8084-cfa0-4adf-afe9-7ad0952ad9a8", "name": "180a6a17-b6a5-4caa-a113-9d8208147f1c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "698bdf1b-1257-4c31-85f8-bacacde1eb47"}}}]}, {"uuid": "9d01e606-f835-479b-b804-4f81eef27ac3", "name": "load_p1rlv176_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "931c8cee-89fe-447d-8788-af1e5f9f8775"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "407f8084-cfa0-4adf-afe9-7ad0952ad9a8"}}}}, {"uuid": "99e5d20b-27ce-4d39-b06a-3c44e17dcda4", "name": "e30615b3-a943-46c8-b4e7-5117468922d2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6697995975485909, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.41657408993223344, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e2b94225-1356-4853-bfa6-176c0a433f9b", "name": "a37c0ac8-c612-4374-9882-9cc962aea7b7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "99e5d20b-27ce-4d39-b06a-3c44e17dcda4"}}}]}, {"uuid": "036940e5-1dde-482f-8a28-985360b13eb8", "name": "load_p1rlv176_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "931c8cee-89fe-447d-8788-af1e5f9f8775"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e2b94225-1356-4853-bfa6-176c0a433f9b"}}}}, {"uuid": "8e2d83b6-5e0f-4403-98cc-978ff787b4ca", "name": "42c249c8-a282-4f34-9fa9-663f5b585402_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4063851199490187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16385595528128288, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "811492a9-f6d4-4b8c-80c0-f863291bfcf7", "name": "e9a6c2c9-1727-417b-9248-d78e56d70a45", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8e2d83b6-5e0f-4403-98cc-978ff787b4ca"}}}]}, {"uuid": "29c19a1f-f23f-4648-97ec-b4c8b61f383f", "name": "load_p1rlv177_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "090d6084-5cc6-473d-99c0-a6309571d633"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "811492a9-f6d4-4b8c-80c0-f863291bfcf7"}}}}, {"uuid": "df803f20-308e-4fe6-844b-d129655543e6", "name": "13f10b9b-e510-446b-a882-74a62ae51dc9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4063851199490187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16385595528128288, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c1b844f0-b3b1-4af5-9201-f97f01504132", "name": "6662538b-8582-480c-b4b6-1ccd18cd440c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "df803f20-308e-4fe6-844b-d129655543e6"}}}]}, {"uuid": "d329efae-e466-4e6b-8fb8-24065f82fa03", "name": "load_p1rlv177_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "090d6084-5cc6-473d-99c0-a6309571d633"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c1b844f0-b3b1-4af5-9201-f97f01504132"}}}}, {"uuid": "29520ab8-c7dd-456f-b4db-2b585ff86051", "name": "9b00560f-85e3-4b99-9b63-bb2a4d907d18_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3919966449037446, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.25526897783955566, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eae97a79-5117-4b6a-9c56-897666501298", "name": "e875f6e1-849f-4df7-bbbb-0b36d4833763", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "29520ab8-c7dd-456f-b4db-2b585ff86051"}}}]}, {"uuid": "44644e90-47ad-4157-a7f5-2dd87e9b3172", "name": "load_p1rlv178_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9debf70-62f4-4870-ad8b-bffc4bc4ad3f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eae97a79-5117-4b6a-9c56-897666501298"}}}}, {"uuid": "0a3b3667-f263-4612-968a-c393477614a0", "name": "8428cf0f-b9e1-4726-a653-40ca39b5e34e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3919966449037446, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.25526897783955566, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0c3ae6b3-dc8d-4283-af06-4e0a124a1079", "name": "d670777d-88ca-4db2-925a-b09d361259bd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0a3b3667-f263-4612-968a-c393477614a0"}}}]}, {"uuid": "d628e1e1-2c23-427b-86a1-8a5297639e27", "name": "load_p1rlv178_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9debf70-62f4-4870-ad8b-bffc4bc4ad3f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0c3ae6b3-dc8d-4283-af06-4e0a124a1079"}}}}, {"uuid": "ea998f67-c04a-4494-98c4-064f1a9f2336", "name": "fa1d8715-c8b9-4f92-9f0d-5f38fd60569d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2601927423507288, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13915962527089715, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "428a7349-08ef-465b-8e74-58ac9d3fe537", "name": "75b7c4a3-cf9d-4665-8a74-5895e7bd2fb6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ea998f67-c04a-4494-98c4-064f1a9f2336"}}}]}, {"uuid": "7a97bfc2-9f49-403d-b794-3f116aba6c9a", "name": "load_p1rlv179_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb03260b-d7d7-4779-ab2c-37c9a1e34d66"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "428a7349-08ef-465b-8e74-58ac9d3fe537"}}}}, {"uuid": "4ad41fa7-5d89-41fa-b3e1-a38addab38d1", "name": "0d7f7e8e-b66a-4544-9ac6-0f8fae22229d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2601927423507288, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13915962527089715, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "58befe5b-f61e-4628-a5d3-a10a18294c9b", "name": "73013f72-7f5e-476f-8c35-1d744b0417ef", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4ad41fa7-5d89-41fa-b3e1-a38addab38d1"}}}]}, {"uuid": "651090f6-dde3-4268-b0f7-9b8f180e98f5", "name": "load_p1rlv179_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb03260b-d7d7-4779-ab2c-37c9a1e34d66"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "58befe5b-f61e-4628-a5d3-a10a18294c9b"}}}}, {"uuid": "ed163f46-f389-484a-94fc-a9b331c41498", "name": "a216477c-85cb-41c9-82fb-76a01c8fefea_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2659851154673674, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7880475847724098, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "842b74ac-4c55-4a3a-ab3f-7c4334c352ef", "name": "601af922-d980-495a-8064-27c3cdb0b3bd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ed163f46-f389-484a-94fc-a9b331c41498"}}}]}, {"uuid": "45f3055c-726c-485c-bdd8-1117acdc412a", "name": "load_p1rlv285_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d3a86df-2ac5-4959-b857-562795ce84ba"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "842b74ac-4c55-4a3a-ab3f-7c4334c352ef"}}}}, {"uuid": "c8ac35f5-ff97-4160-9768-d475b43c0558", "name": "b3738bf2-a2c6-46f6-8e66-384b2579bf42_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2659851154673674, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7880475847724098, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a258932-2782-467b-b763-1a702c820449", "name": "a51f40ca-ad49-4ccd-b8ac-c34e8ab16026", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c8ac35f5-ff97-4160-9768-d475b43c0558"}}}]}, {"uuid": "6479420b-32b6-41c7-a90d-68d7d778a703", "name": "load_p1rlv285_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d3a86df-2ac5-4959-b857-562795ce84ba"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0a258932-2782-467b-b763-1a702c820449"}}}}, {"uuid": "1c177bae-3836-497a-9053-d4ead03fbd3c", "name": "e3d417f2-bf21-4f7c-8f2f-5987506a39da_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7aa7dc8d-fb03-4602-a9c7-2c8a3f57e11e", "name": "fe88390d-2742-4c94-9aac-b19ed839235a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1c177bae-3836-497a-9053-d4ead03fbd3c"}}}]}, {"uuid": "4556cea0-a96e-4e33-89b2-36d259fbf452", "name": "load_p1rlv337_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57b88281-b728-4779-82b1-4cc9eb4b41b1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7aa7dc8d-fb03-4602-a9c7-2c8a3f57e11e"}}}}, {"uuid": "f1501d64-73bc-43d1-b883-0c114a180b3f", "name": "b1dd7efd-f593-4adc-8da9-7256bd29e94f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "472244fd-1054-4fbf-a42e-caac2dc2776d", "name": "41ced716-013c-4d5c-a7ed-ff05a893b220", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f1501d64-73bc-43d1-b883-0c114a180b3f"}}}]}, {"uuid": "9ea99031-1a73-4860-8941-03176411c5bf", "name": "load_p1rlv337_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57b88281-b728-4779-82b1-4cc9eb4b41b1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "472244fd-1054-4fbf-a42e-caac2dc2776d"}}}}, {"uuid": "d204acfa-ed37-4a6b-95eb-8de35bfabbc1", "name": "515ac681-bc87-4785-98b5-8f8a94c86b73_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2045141672666357, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3046267940472902, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7289962d-1ada-451f-b2c9-e221764be8f2", "name": "21c661fe-a346-4b28-aa4e-23df3068ca6c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d204acfa-ed37-4a6b-95eb-8de35bfabbc1"}}}]}, {"uuid": "6cbf86aa-64e8-43d6-a2b2-92c2c3acfb3f", "name": "load_p1rlv338_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6b2aba6-a289-4a50-a131-2064047d1341"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7289962d-1ada-451f-b2c9-e221764be8f2"}}}}, {"uuid": "42fbd9cf-1d1c-4abc-85bd-116b6ddf9bfa", "name": "14038502-db61-4a46-b69e-1c39f41d22a3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2045141672666357, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3046267940472902, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1ee17721-78a2-48e2-b84d-63ff7d2774e2", "name": "854c52d5-f691-4c09-b7aa-2defe0872bad", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "42fbd9cf-1d1c-4abc-85bd-116b6ddf9bfa"}}}]}, {"uuid": "c5486f4c-d67c-491a-a3b9-721e60f5bfe3", "name": "load_p1rlv338_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6b2aba6-a289-4a50-a131-2064047d1341"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1ee17721-78a2-48e2-b84d-63ff7d2774e2"}}}}, {"uuid": "6439cd2a-e885-4ff0-886a-36d603472278", "name": "6809aa00-7d60-4f12-bccd-5637e38d38b4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.749950841708346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2019248045205122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "05626810-c934-47c1-9b5e-0be633089952", "name": "9e0a0824-5fa4-4caa-a072-29dd33106920", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6439cd2a-e885-4ff0-886a-36d603472278"}}}]}, {"uuid": "3923f8d0-d62f-4abe-a647-2a3892b503e7", "name": "load_p1rlv340_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb4797d6-b46e-4058-8985-d9f4b660f0a7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "05626810-c934-47c1-9b5e-0be633089952"}}}}, {"uuid": "6c6c9a34-29b0-4314-9fe4-d2c4c3852ee8", "name": "96a9059b-9ada-4807-a11d-56012857b21e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.749950841708346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2019248045205122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6e25347e-dd30-4db8-99fb-a71a4a549692", "name": "ab84c3c8-001a-4eb0-8134-2b8035150c17", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c6c9a34-29b0-4314-9fe4-d2c4c3852ee8"}}}]}, {"uuid": "eb14f439-9aa1-4079-96fe-45e6e5847e93", "name": "load_p1rlv340_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb4797d6-b46e-4058-8985-d9f4b660f0a7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6e25347e-dd30-4db8-99fb-a71a4a549692"}}}}, {"uuid": "ab205c2d-87ef-4ce5-90dc-e70ae13d27f4", "name": "2005a09f-d78d-4c2c-8b43-2a9aba13acc5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7771517670040275, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8838563298920215, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e6a4afe8-741d-460d-9bcc-f3f77a31cc45", "name": "09c46746-251c-4784-8f41-c60a076be7f3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ab205c2d-87ef-4ce5-90dc-e70ae13d27f4"}}}]}, {"uuid": "561c4565-dc97-4f33-8ad7-42971c29c365", "name": "load_p1rlv341_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54f0ea2c-3849-4ff0-ad8c-e3f65515d178"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e6a4afe8-741d-460d-9bcc-f3f77a31cc45"}}}}, {"uuid": "fbebc68b-d886-4b60-bf1b-7197de9935e5", "name": "d6adca28-a492-4e3b-88dd-c246096a3336_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7771517670040275, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8838563298920215, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "191609e9-fb6c-46b6-95dd-29c9168574f4", "name": "156033c8-3e75-405d-af6e-0eb9dc3de4fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fbebc68b-d886-4b60-bf1b-7197de9935e5"}}}]}, {"uuid": "afcd055b-9509-4910-b384-8233cc9e4e6b", "name": "load_p1rlv341_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54f0ea2c-3849-4ff0-ad8c-e3f65515d178"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "191609e9-fb6c-46b6-95dd-29c9168574f4"}}}}, {"uuid": "f63cca78-c62d-445c-8a2e-215e0eab54d9", "name": "b7983a4b-95a0-45fe-b036-0f5c851a90fa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.4540014644243024, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4055170204295049, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82e02e2e-8676-4814-862e-8c81992484b3", "name": "914f473c-173c-49fd-8ea2-c63522e0a60e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f63cca78-c62d-445c-8a2e-215e0eab54d9"}}}]}, {"uuid": "a78c25f5-e873-4dd8-b731-2c3ff4901b82", "name": "load_p1rlv342_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13754fdb-4039-49fb-b584-8437191dfb2b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "82e02e2e-8676-4814-862e-8c81992484b3"}}}}, {"uuid": "3acb654a-aa3c-4022-915f-e73e57b302cd", "name": "241003e9-2fef-4a7f-9350-0e620c9a620c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.4540014644243024, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4055170204295049, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3b3af3e2-a813-4fdc-9902-68f5e308c8d5", "name": "9f040f50-6d2d-4f18-bc6f-2ab763c4f055", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3acb654a-aa3c-4022-915f-e73e57b302cd"}}}]}, {"uuid": "29b09a02-af7d-4f10-a1a5-5b3bb8ac37a8", "name": "load_p1rlv342_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13754fdb-4039-49fb-b584-8437191dfb2b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3b3af3e2-a813-4fdc-9902-68f5e308c8d5"}}}}, {"uuid": "46d2407f-a957-4126-a965-30b5fbbce9d9", "name": "48f60e72-1afb-466c-9907-47aa705e05f0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.13715702476687, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3795210711832634, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "780f8a0e-2872-4cd4-9a86-380a9be5d8a3", "name": "45b5032e-3500-4368-8510-e49470dc54fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "46d2407f-a957-4126-a965-30b5fbbce9d9"}}}]}, {"uuid": "7ca6a310-ece1-4515-b89c-91799dfde079", "name": "load_p1rlv343_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0197ef22-9f8f-48a9-84de-663a7ce22773"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "780f8a0e-2872-4cd4-9a86-380a9be5d8a3"}}}}, {"uuid": "31aaa454-e1df-4166-aa08-efef0b899f81", "name": "3e9d777a-3af9-40a3-b89f-aaa24aa1797e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.13715702476687, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3795210711832634, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cbe8525b-a364-4c00-bada-3cb6d22575fa", "name": "85dab30e-30a4-423c-b797-cd08b694cbdd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "31aaa454-e1df-4166-aa08-efef0b899f81"}}}]}, {"uuid": "1404590a-7410-49e3-a904-b7e2f385f6a7", "name": "load_p1rlv343_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0197ef22-9f8f-48a9-84de-663a7ce22773"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cbe8525b-a364-4c00-bada-3cb6d22575fa"}}}}, {"uuid": "004d9144-06c7-40fa-a842-d07cf3457dac", "name": "98219f76-b003-414b-a065-9d41a2cd7b67_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.2930994643856595, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9073205938076818, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a757014b-52d3-40d4-849a-0de412ddaca2", "name": "ffe8f721-ff1c-41e6-adeb-b778f310e837", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "004d9144-06c7-40fa-a842-d07cf3457dac"}}}]}, {"uuid": "f8c96c76-4500-4902-be1e-8995417b8744", "name": "load_p1rlv377_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e1ea241-5329-4db5-996a-df09a9c25687"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a757014b-52d3-40d4-849a-0de412ddaca2"}}}}, {"uuid": "0dcf4eab-54e8-4541-8890-27e214ff59b7", "name": "a5c27446-e8c1-4d61-bfbd-9c778dabe13c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.2930994643856595, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9073205938076818, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "427eb9c6-1136-418d-abde-61d3a2b4041d", "name": "5432649f-73cd-4435-a788-f7d1b72d0967", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0dcf4eab-54e8-4541-8890-27e214ff59b7"}}}]}, {"uuid": "5ad57ec9-af8b-4b00-a356-ecf78415ae20", "name": "load_p1rlv377_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e1ea241-5329-4db5-996a-df09a9c25687"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "427eb9c6-1136-418d-abde-61d3a2b4041d"}}}}, {"uuid": "94c37143-9b5c-474e-99b2-b002ffbfccb4", "name": "3a44a044-db43-48e8-a935-f5e04bd91034_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.651809392632849, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.766759151751063, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "97f2d645-e451-42da-aece-d78a6970ecfc", "name": "a92532cc-0b0b-49f2-ae7c-ea34320889c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "94c37143-9b5c-474e-99b2-b002ffbfccb4"}}}]}, {"uuid": "d80a4f02-d2e1-4f5a-80e8-45a4378ac616", "name": "load_p1rlv378_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3ff63a0-bf3f-43b0-807c-935467b4fe46"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "97f2d645-e451-42da-aece-d78a6970ecfc"}}}}, {"uuid": "0e323603-a17e-407b-83af-62febe03a71c", "name": "ecaa4e08-c740-4566-8601-9a1491659c6e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.651809392632849, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.766759151751063, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "60f67866-5481-4e96-8dd8-0240b485e74e", "name": "76c22656-994c-4b14-9c13-7b9f159d03dc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0e323603-a17e-407b-83af-62febe03a71c"}}}]}, {"uuid": "8d2908f9-6481-4036-9550-bc9b126c0e7a", "name": "load_p1rlv378_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3ff63a0-bf3f-43b0-807c-935467b4fe46"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "60f67866-5481-4e96-8dd8-0240b485e74e"}}}}, {"uuid": "290ee85f-789b-4ced-8dea-094061874c37", "name": "de0a417d-6eae-4df1-9d8e-97a3d259a85c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.096838644473719, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3876192860701033, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6e4cac71-6f88-414e-9062-1212fb7c57de", "name": "d818b75f-425c-4d11-992e-fbae2b838669", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "290ee85f-789b-4ced-8dea-094061874c37"}}}]}, {"uuid": "73f6f7ba-a150-4170-96bf-a852b546e239", "name": "load_p1rlv379_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50225dcf-40bc-44b5-9dec-072ac5b2334e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6e4cac71-6f88-414e-9062-1212fb7c57de"}}}}, {"uuid": "117a6938-112f-45c1-8ae5-c713f9d0a91b", "name": "d1460c02-979f-46df-9f4e-92cd244a3564_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.096838644473719, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3876192860701033, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9f33b4de-345c-4f35-8e17-a9a339cf2869", "name": "022bd3c9-10ad-44f1-b125-18dea4f660f5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "117a6938-112f-45c1-8ae5-c713f9d0a91b"}}}]}, {"uuid": "34220f1f-be21-4cc4-8bb4-4b7eade70fcb", "name": "load_p1rlv379_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50225dcf-40bc-44b5-9dec-072ac5b2334e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9f33b4de-345c-4f35-8e17-a9a339cf2869"}}}}, {"uuid": "b0b45149-b134-4171-b53b-6dd758d0a7a4", "name": "0010f4b1-dc0e-4d20-b884-f9e6ec67d62e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5996895391512607, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5332968923160806, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "24a9217d-fe72-4420-8696-febd57d3910f", "name": "834f12fe-e7fb-4be2-924c-e758065cedb2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b0b45149-b134-4171-b53b-6dd758d0a7a4"}}}]}, {"uuid": "f534baff-d593-496b-b97d-4d6125708942", "name": "load_p1rlv380_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ee07ef9-b7b0-4457-be1c-78e754dbcfc7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "24a9217d-fe72-4420-8696-febd57d3910f"}}}}, {"uuid": "13a657a3-c0e6-4664-bbdf-f01b5a50223b", "name": "cd7ba6a9-1d52-499b-9fde-a6e4f4375cb7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5996895391512607, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5332968923160806, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fb8d2ec8-db5f-492e-8273-caea9dfba693", "name": "4c6be107-899d-468e-b909-872fd2bdd8a9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "13a657a3-c0e6-4664-bbdf-f01b5a50223b"}}}]}, {"uuid": "75ccf78c-c765-41a6-bb56-37de514dfd86", "name": "load_p1rlv380_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ee07ef9-b7b0-4457-be1c-78e754dbcfc7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fb8d2ec8-db5f-492e-8273-caea9dfba693"}}}}, {"uuid": "9edb37d5-caa0-4b00-9a26-a1aef7b642d2", "name": "2f2f95a1-ff09-4219-9373-12da064989c4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2825930802168721, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5903675615779559, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9f696408-f8d5-435c-b48a-a1b120d685f5", "name": "f3de3b82-5836-4416-aeac-2bd18e3337a2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9edb37d5-caa0-4b00-9a26-a1aef7b642d2"}}}]}, {"uuid": "1201db9d-fab3-415c-8e76-196f246cee65", "name": "load_p1rlv412_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b33ed36-116b-4741-9374-6927bd537427"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9f696408-f8d5-435c-b48a-a1b120d685f5"}}}}, {"uuid": "73ab955f-6770-4bd4-8b30-d11d86f9c7e3", "name": "f5f99842-6cc1-45f2-9739-1134e07d34ec_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2825930802168721, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5903675615779559, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fd4a14f5-a2b4-4f81-821c-6ddbe1b5a91a", "name": "ec891b7a-d6d3-4735-8205-10cb67fdb0b6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "73ab955f-6770-4bd4-8b30-d11d86f9c7e3"}}}]}, {"uuid": "1b537d77-e45c-4ae0-8dea-bc86cdd481b6", "name": "load_p1rlv412_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b33ed36-116b-4741-9374-6927bd537427"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fd4a14f5-a2b4-4f81-821c-6ddbe1b5a91a"}}}}, {"uuid": "84949f0b-d44d-4a0a-9a39-3365a68a2314", "name": "b66335e1-8e77-471c-a647-d252b422f28a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5218330234822437, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6111559757217505, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "956c3863-e83f-4114-89f4-119b9934a4bc", "name": "f20afc4a-dda8-4342-a86a-736bfec026d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "84949f0b-d44d-4a0a-9a39-3365a68a2314"}}}]}, {"uuid": "257f2e68-1456-4e2f-8fe7-fe6c17012ce3", "name": "load_p1rlv413_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8408ac87-a086-46bc-9d88-cca79e17dd62"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "956c3863-e83f-4114-89f4-119b9934a4bc"}}}}, {"uuid": "b2175bbc-4c32-40bb-9689-315b3bcc6d77", "name": "4d03acdd-3b5a-4a2f-9bde-c864876ffc0f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5218330234822437, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6111559757217505, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5607d053-3b06-4109-a565-cfa46dd43ff6", "name": "114afa60-6b70-4d0d-88be-b71871e0249b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b2175bbc-4c32-40bb-9689-315b3bcc6d77"}}}]}, {"uuid": "3cd0305c-20bb-422f-ade5-5c72aa5bf079", "name": "load_p1rlv413_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8408ac87-a086-46bc-9d88-cca79e17dd62"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5607d053-3b06-4109-a565-cfa46dd43ff6"}}}}, {"uuid": "25658ac8-9f93-4d5c-92bd-34dd271c0f9e", "name": "668f02ae-de18-4809-9dd7-a058c84d5985_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.307247144150686, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17783357819798717, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a7fe75cd-0f4b-4b3c-ae8b-71f0919b3f14", "name": "fb1e58e1-f7b4-4623-8ba6-1d4e7529a98e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "25658ac8-9f93-4d5c-92bd-34dd271c0f9e"}}}]}, {"uuid": "35b4e3bb-abfb-4915-bf67-85f1523b4a79", "name": "load_p1rlv414_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec2c1edd-78b1-4436-85cc-2fbc7d880b87"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a7fe75cd-0f4b-4b3c-ae8b-71f0919b3f14"}}}}, {"uuid": "b0150c1f-3a29-4ff7-826e-65ce32bf3402", "name": "3eb4c88f-abac-453f-9d93-39ef129a1d8f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.307247144150686, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17783357819798717, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ff753503-a4c9-4e5b-a4dd-6695e34a72cf", "name": "30305ae5-0ba2-41ba-8318-c583c284b3b7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b0150c1f-3a29-4ff7-826e-65ce32bf3402"}}}]}, {"uuid": "4bdf7a06-175a-4680-9f3f-f675b8c9e04b", "name": "load_p1rlv414_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec2c1edd-78b1-4436-85cc-2fbc7d880b87"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ff753503-a4c9-4e5b-a4dd-6695e34a72cf"}}}}, {"uuid": "5a4ad912-137b-4edb-80e4-bdf9777227e0", "name": "b5e7052a-bbd0-4b2c-ab85-b69824d5cd68_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5478654763148745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5646840796232575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2d39b745-c630-47ab-9da9-88d2b940963e", "name": "100b605b-2a00-4b97-9ec6-48a6ccc8f450", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5a4ad912-137b-4edb-80e4-bdf9777227e0"}}}]}, {"uuid": "a9fd2337-e212-4577-b3e0-d54b489d242f", "name": "load_p1rlv415_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b54aae8-5a94-4e04-882f-748e1c5f1390"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2d39b745-c630-47ab-9da9-88d2b940963e"}}}}, {"uuid": "9752f792-cdad-4a22-8069-f260252ead54", "name": "79c4a47c-32a3-4c67-9a2b-803120fdff31_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5478654763148745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5646840796232575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5bb18331-14c7-4223-b4e8-25be9b609caa", "name": "46a57404-cee0-492b-84c7-8022e3de81fc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9752f792-cdad-4a22-8069-f260252ead54"}}}]}, {"uuid": "544ef15a-50b6-4c3e-bcfb-05594c086a25", "name": "load_p1rlv415_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b54aae8-5a94-4e04-882f-748e1c5f1390"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5bb18331-14c7-4223-b4e8-25be9b609caa"}}}}, {"uuid": "236f88fc-0b20-4017-9d1f-675e72532aa8", "name": "5d27f300-a078-47fe-8758-e12c363092a5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2437699409140923, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5571842941855458, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fe160672-65f9-422a-9671-4bdc27a622cb", "name": "f786ba5b-b576-41c9-b08d-f961568173e3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "236f88fc-0b20-4017-9d1f-675e72532aa8"}}}]}, {"uuid": "4ff614f9-c0c4-40d4-bfa4-88e78ed45956", "name": "load_p1rlv416_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99abc7dc-8e15-420f-9bc9-0e6229d4dab3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fe160672-65f9-422a-9671-4bdc27a622cb"}}}}, {"uuid": "8aed49d1-541b-4b5c-9f2e-3c5cff27502e", "name": "1e7379ad-fa51-40c3-90eb-d3c5e01261aa_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2437699409140923, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5571842941855458, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1d2b8e34-0dc2-4c63-81ad-6d79487b2e54", "name": "40629f65-fa44-4e45-a92a-3643edc7dc74", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8aed49d1-541b-4b5c-9f2e-3c5cff27502e"}}}]}, {"uuid": "82c78be7-41d1-4915-8907-9969c6287ce0", "name": "load_p1rlv416_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99abc7dc-8e15-420f-9bc9-0e6229d4dab3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1d2b8e34-0dc2-4c63-81ad-6d79487b2e54"}}}}, {"uuid": "55122e3e-f38d-4d1b-86da-c7401f27692e", "name": "fcbad943-9a9c-47ee-a121-c4676330ce18_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1698158732703443, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8490689598373361, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ef1bdc26-4c6e-4e24-8d2f-6bb4f0406a79", "name": "2f060849-2e72-4eea-b384-048580d8e5fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "55122e3e-f38d-4d1b-86da-c7401f27692e"}}}]}, {"uuid": "cd8c15e0-e322-449b-bce6-7a643e578731", "name": "load_p1rlv417_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49dbdd44-a36a-46b5-aef8-558ef7693315"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ef1bdc26-4c6e-4e24-8d2f-6bb4f0406a79"}}}}, {"uuid": "74a63396-c2b6-4f4b-af3f-43efe8e564a9", "name": "c7df32c2-cdf3-45b5-90fc-57e75e7e30b1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1698158732703443, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8490689598373361, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "49b098d1-e734-47b1-a9da-6c4a48a0520a", "name": "30e3bf61-f498-4702-81ef-3a75714458e8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "74a63396-c2b6-4f4b-af3f-43efe8e564a9"}}}]}, {"uuid": "f8e88484-6c6e-45e3-a52a-e736bf05bff7", "name": "load_p1rlv417_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49dbdd44-a36a-46b5-aef8-558ef7693315"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "49b098d1-e734-47b1-a9da-6c4a48a0520a"}}}}, {"uuid": "ab938fa9-a68b-400e-a8e7-d64902836b00", "name": "32268d5a-2da6-4aa3-b876-ced5699e0813_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "58a9e0b3-d78c-4ac9-9604-2a109b6f58a4", "name": "b375611a-bb86-4e95-801c-434f495d8c60", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ab938fa9-a68b-400e-a8e7-d64902836b00"}}}]}, {"uuid": "e39d1d14-3bf8-4464-ae5e-e71464d9438f", "name": "load_p1rlv418_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b54aae8-5a94-4e04-882f-748e1c5f1390"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "58a9e0b3-d78c-4ac9-9604-2a109b6f58a4"}}}}, {"uuid": "1f37b3c6-3ecf-43ad-9e38-3a3dc3a0cc26", "name": "6f014ce4-d03c-4b4e-945a-3d1eba73bdec_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "63163c6c-7cba-4439-850c-9084634f2124", "name": "f4ba3843-c683-4ff0-92b9-ef860b481e32", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1f37b3c6-3ecf-43ad-9e38-3a3dc3a0cc26"}}}]}, {"uuid": "f244f5bf-9001-4806-a729-a2167668ce93", "name": "load_p1rlv418_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b54aae8-5a94-4e04-882f-748e1c5f1390"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "63163c6c-7cba-4439-850c-9084634f2124"}}}}, {"uuid": "55a6f0de-1376-4b1c-b506-a6f1d294f948", "name": "0165d7b3-8b43-47c0-8136-0fbfff30a059_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7500687162104853, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7707974088873139, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b043d947-32fc-4198-b244-45fc8c302d0a", "name": "bf1977d4-2132-4dfc-97c4-179e2d725e4a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "55a6f0de-1376-4b1c-b506-a6f1d294f948"}}}]}, {"uuid": "d8182e93-d5f4-4313-ade2-e469a3bb5d8c", "name": "load_p1rlv419_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7935b9c-b631-432c-a322-9beea73f1fc4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b043d947-32fc-4198-b244-45fc8c302d0a"}}}}, {"uuid": "dd9ae778-2841-4cae-80ae-503efc54ca9c", "name": "6f2adaac-f7b6-408c-9907-ab7bc43f7bee_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7500687162104853, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7707974088873139, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2c97cf19-a37a-4490-bae2-368b37e51bca", "name": "7962d5af-9a27-4c06-9a06-c5c13eb29a5b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dd9ae778-2841-4cae-80ae-503efc54ca9c"}}}]}, {"uuid": "6fba622d-d85c-4cfa-b494-58951b880d4e", "name": "load_p1rlv419_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7935b9c-b631-432c-a322-9beea73f1fc4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2c97cf19-a37a-4490-bae2-368b37e51bca"}}}}, {"uuid": "2a3896a4-969d-48ca-baab-71091982350d", "name": "3cff9dd6-70ac-4346-b7e0-30d7b4c5b2cf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6434260893942235, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2588956175598443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6447e97c-5dd4-4d30-a85b-0bc2e08e72db", "name": "5995a59c-f31e-42b9-b7b1-7f975115716b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2a3896a4-969d-48ca-baab-71091982350d"}}}]}, {"uuid": "0aa79a4c-aea1-4025-9923-8593ea232b24", "name": "load_p1rlv420_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4d7ed8-5ddd-4127-87ab-eb3f48a580c2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6447e97c-5dd4-4d30-a85b-0bc2e08e72db"}}}}, {"uuid": "cdec3867-35e4-4fb8-8021-a976b3d2b085", "name": "9cd4ca9f-c37d-4ab7-9917-3d19039f140a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6434260893942235, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2588956175598443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "25b0c049-def9-4072-b041-5bf6ee171db9", "name": "d0b9cd2b-09f6-49ae-aa4e-88d98a0ebd82", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cdec3867-35e4-4fb8-8021-a976b3d2b085"}}}]}, {"uuid": "94167872-f880-4f9c-af3a-1e15003d571b", "name": "load_p1rlv420_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4d7ed8-5ddd-4127-87ab-eb3f48a580c2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "25b0c049-def9-4072-b041-5bf6ee171db9"}}}}, {"uuid": "3c53efed-5f98-4e1d-9121-1df30d025cc9", "name": "62b17c48-45de-45fd-9566-27fe55bf2649_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6669289783709, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.056901546523703654, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "996a80b3-261b-43a1-91c5-21c792a73994", "name": "8b92c237-c090-4e84-b560-99c2e5c9ae24", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3c53efed-5f98-4e1d-9121-1df30d025cc9"}}}]}, {"uuid": "563cc9c0-de0d-400a-8f79-e346ad461693", "name": "load_p1rlv421_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12dcb168-1bfe-448b-8d9a-f5cb4c61aafe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "996a80b3-261b-43a1-91c5-21c792a73994"}}}}, {"uuid": "7de77097-4a79-4bfe-b65e-29cbf44811c2", "name": "6e0fe43e-b16c-4f7e-9349-d521a6f60151_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6669289783709, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.056901546523703654, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0fde27dd-70e3-42a9-b281-117a5b6ded40", "name": "9d4161dc-d429-4582-96aa-69a6db295ab8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7de77097-4a79-4bfe-b65e-29cbf44811c2"}}}]}, {"uuid": "c797796a-12c9-439b-903d-d720319a9f5d", "name": "load_p1rlv421_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12dcb168-1bfe-448b-8d9a-f5cb4c61aafe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0fde27dd-70e3-42a9-b281-117a5b6ded40"}}}}, {"uuid": "05991d9c-522e-4349-a36c-fd44e2dd07f1", "name": "324242e3-d208-4a59-9931-b871fa753018_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.933146793098512, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9686684100837105, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9cfd504c-4877-491c-912c-fbe81dace76d", "name": "1c7d4e5f-3295-40b5-81f0-0c4074306a7c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "05991d9c-522e-4349-a36c-fd44e2dd07f1"}}}]}, {"uuid": "ff597d6c-e00d-46a3-ba9b-b0e0829959ac", "name": "load_p1rlv422_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa7bb51b-8ba8-4a05-872a-7f5ce084fe88"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9cfd504c-4877-491c-912c-fbe81dace76d"}}}}, {"uuid": "c10cf9cb-91fc-4e09-8683-2c939cc3a0bb", "name": "da66753e-185f-4c0c-a216-68566b61192d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.933146793098512, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9686684100837105, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4d9d9d46-178a-427d-9a33-efb4da3cefdc", "name": "cd2b9061-a50c-466b-be80-2aefbd0c6ce2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c10cf9cb-91fc-4e09-8683-2c939cc3a0bb"}}}]}, {"uuid": "2b22dc58-7860-4849-a2c5-d982f61301e8", "name": "load_p1rlv422_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa7bb51b-8ba8-4a05-872a-7f5ce084fe88"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4d9d9d46-178a-427d-9a33-efb4da3cefdc"}}}}, {"uuid": "33520d61-57c6-4233-8f24-2ca00485cd8f", "name": "b29beaa2-d8b8-47b8-abe4-d78d560ae6a2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0491915565570302, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1506537762556939, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "94a80965-d56a-49e4-99d1-7130b1ec198b", "name": "74a55b1d-5afa-4d60-9810-cb3ec599c176", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "33520d61-57c6-4233-8f24-2ca00485cd8f"}}}]}, {"uuid": "bfa11df5-c4a4-4ab5-9b53-898280a44040", "name": "load_p1rlv423_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c1e9680-f7de-497c-953a-54f4db2899e2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "94a80965-d56a-49e4-99d1-7130b1ec198b"}}}}, {"uuid": "a118a7a2-88e6-42c5-89d9-6b41a6ab039e", "name": "e3e4422d-36a0-4d91-a6e5-924efb122083_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0491915565570302, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1506537762556939, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3182748a-a6d3-48e9-941a-e62456a53155", "name": "98a6588c-0e54-4694-a589-f9f6c573c398", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a118a7a2-88e6-42c5-89d9-6b41a6ab039e"}}}]}, {"uuid": "ccf1c0f6-b41e-4007-9928-38c149b8bd6e", "name": "load_p1rlv423_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c1e9680-f7de-497c-953a-54f4db2899e2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3182748a-a6d3-48e9-941a-e62456a53155"}}}}, {"uuid": "4b837012-2e6a-4090-970b-750f34a1077a", "name": "510ecdc7-345f-4f8a-ac44-5323ed39c728_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.048430097374791, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0714377119995753, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bca6a3d7-d6ea-448c-870e-e5499cb6e352", "name": "cc5170e1-d5c0-4e1e-bcdf-4f86e9f197ee", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4b837012-2e6a-4090-970b-750f34a1077a"}}}]}, {"uuid": "00ca86be-72b4-4af6-9b27-7d5bd262f58b", "name": "load_p1rlv424_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1a91c8c-aabd-4fad-8306-908f186a5744"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bca6a3d7-d6ea-448c-870e-e5499cb6e352"}}}}, {"uuid": "5ee2aac4-fd28-492c-9fbf-e14dcfeb1f56", "name": "565efea5-5d16-4069-b9fe-e78a3eb0aedd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.048430097374791, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0714377119995753, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8491090d-1a03-4ae5-bc2b-f1030da5f1f0", "name": "eb6eef64-a023-4f01-8fcf-4239d57adb32", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5ee2aac4-fd28-492c-9fbf-e14dcfeb1f56"}}}]}, {"uuid": "3d6b51d0-c70c-4997-b523-7e7d83ed4353", "name": "load_p1rlv424_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1a91c8c-aabd-4fad-8306-908f186a5744"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8491090d-1a03-4ae5-bc2b-f1030da5f1f0"}}}}, {"uuid": "4c4d408d-bb5c-4094-8251-2bc68ca55034", "name": "310a4edf-3ccc-42ce-a1a4-b52e410a0b85_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8920557288657344, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21990443750848332, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "65ef3c3d-4484-4297-aba5-6eab04605e0f", "name": "24317571-168d-4b75-88d9-4f43c51bc8cf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4c4d408d-bb5c-4094-8251-2bc68ca55034"}}}]}, {"uuid": "d306d9a0-8ad6-4e4a-9f58-981adc0e3883", "name": "load_p1rlv439_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f771660-4dad-43df-b38b-7da5f6180a25"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "65ef3c3d-4484-4297-aba5-6eab04605e0f"}}}}, {"uuid": "3ce337f3-148a-4e7d-9b88-c7750feec37b", "name": "c3a89a09-dc57-4336-ab2b-cad574ec511b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8920557288657344, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21990443750848332, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7c5b24e7-f210-4a14-978c-d3f2bb483082", "name": "2587354e-c5c0-4ba2-ac28-50bec7d9a608", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3ce337f3-148a-4e7d-9b88-c7750feec37b"}}}]}, {"uuid": "256a6866-9c80-4f16-82fd-de7eaae686d7", "name": "load_p1rlv439_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f771660-4dad-43df-b38b-7da5f6180a25"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7c5b24e7-f210-4a14-978c-d3f2bb483082"}}}}, {"uuid": "5261793a-bf29-4c04-8a01-f2d88cc6722d", "name": "2df4b933-77e6-4412-9d27-90b3200a8993_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 16.24059147715281, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.317949795825311, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c4b10fa3-3e22-4c45-9915-cdb65b4cd420", "name": "2df4b933-77e6-4412-9d27-90b3200a8993_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 16.24059147715281, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.317949795825311, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bef03be8-2fa9-4053-97dd-093966a78bee", "name": "2df4b933-77e6-4412-9d27-90b3200a8993_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 16.24059147715281, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.317949795825311, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0bce5227-fc0c-42c0-a499-e53e72b093b7", "name": "58ae15dd-8489-4925-9705-4352ad3f5f7c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5261793a-bf29-4c04-8a01-f2d88cc6722d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c4b10fa3-3e22-4c45-9915-cdb65b4cd420"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bef03be8-2fa9-4053-97dd-093966a78bee"}}}]}, {"uuid": "b1e406c4-63ea-4a23-9d16-363dd259c73b", "name": "load_p1rlv440", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a23f97bc-e7ef-4f64-9e64-314f4a4e17d8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0bce5227-fc0c-42c0-a499-e53e72b093b7"}}}}, {"uuid": "9894d818-8308-4bbc-9f1e-d9074e63f268", "name": "4ad605bf-5a6e-4a72-9956-2536b0fc3b8a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4856814769108864, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8267323554826451, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c542f525-2856-42c6-9de3-5a1f4448113a", "name": "c9021d60-4ed5-4971-adc8-a100beff3342", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9894d818-8308-4bbc-9f1e-d9074e63f268"}}}]}, {"uuid": "5634e75d-43ab-46fd-a2f7-8f7fd2130563", "name": "load_p1rlv441_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a778b00-482c-4b81-8213-f17202a105fa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c542f525-2856-42c6-9de3-5a1f4448113a"}}}}, {"uuid": "25db585c-f02f-4651-9b6a-4fde07288939", "name": "9e1ec08a-7e98-41f3-aec3-501011911653_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4856814769108864, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8267323554826451, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "308df291-ae5e-463c-b62e-5f1df7e8c52f", "name": "a53be65f-b7dc-44ce-bc4c-8cf2befe86cf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "25db585c-f02f-4651-9b6a-4fde07288939"}}}]}, {"uuid": "67265199-e9b6-4225-bd80-a5303316a244", "name": "load_p1rlv441_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a778b00-482c-4b81-8213-f17202a105fa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "308df291-ae5e-463c-b62e-5f1df7e8c52f"}}}}, {"uuid": "9487f595-09d1-4a90-beeb-96cd696e5b1d", "name": "6a0a6019-6ae9-4cb3-8832-1f1ae030f058_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.930214175792893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.08514782397789, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "453f8cfc-b505-47b5-a735-bd50a661eff3", "name": "a2903bfb-4002-4629-aa28-100a4ac73fbf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9487f595-09d1-4a90-beeb-96cd696e5b1d"}}}]}, {"uuid": "6d52ad2a-64bf-47cf-8206-746d44da5175", "name": "load_p1rlv442_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cd667a9-c0ef-49ce-b6ee-7e474d9ae761"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "453f8cfc-b505-47b5-a735-bd50a661eff3"}}}}, {"uuid": "216ec404-c4bd-4582-a482-e9adf27caac9", "name": "b58ba976-9653-4229-9372-2c11f1567a42_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.930214175792893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.08514782397789, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2fce8bd0-bd8d-47c6-a08f-db1e08281e9a", "name": "3de521c0-c2e3-4a13-b814-a09c6af31021", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "216ec404-c4bd-4582-a482-e9adf27caac9"}}}]}, {"uuid": "57e4bfe6-8249-482d-9a03-7ad1b74d4c0a", "name": "load_p1rlv442_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cd667a9-c0ef-49ce-b6ee-7e474d9ae761"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2fce8bd0-bd8d-47c6-a08f-db1e08281e9a"}}}}, {"uuid": "9d74f642-1a58-435c-9922-c95f0a9d371a", "name": "ef632798-1b8c-46da-93d8-b0772f08d5f5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7859412473782077, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.762455747973555, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a79978f4-da2d-4611-9e3e-c29a191a7c4c", "name": "0406b84e-e9a4-4851-a993-006de690057e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9d74f642-1a58-435c-9922-c95f0a9d371a"}}}]}, {"uuid": "55cacdf5-2f34-4f91-a63c-67bda85ddefd", "name": "load_p1rlv443_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2100c17-c0e6-47e9-87f8-72016b22dd4b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a79978f4-da2d-4611-9e3e-c29a191a7c4c"}}}}, {"uuid": "b92e692b-da63-4550-a63f-c76c7e192283", "name": "fc7a501e-9c79-454e-be5c-c64f19f2ba0a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7859412473782077, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.762455747973555, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1a7e41f3-f106-40cd-b1c9-468f9c6f612b", "name": "3fce7f30-a9c4-47c8-a6fa-7dcfafdf4e9f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b92e692b-da63-4550-a63f-c76c7e192283"}}}]}, {"uuid": "e74a9ba3-c552-4ba4-ab09-d0ac5a978fcd", "name": "load_p1rlv443_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2100c17-c0e6-47e9-87f8-72016b22dd4b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1a7e41f3-f106-40cd-b1c9-468f9c6f612b"}}}}, {"uuid": "ba02ec92-c842-49fd-a668-18b6792718d9", "name": "315ec56e-8ab3-4602-b49d-bc960908c944_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1461342593009323, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5165512162199262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fc06d0ff-46e7-414c-a1a0-9fec97e1ed9a", "name": "b9047550-16e2-4235-bc0a-cdc6804ea240", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ba02ec92-c842-49fd-a668-18b6792718d9"}}}]}, {"uuid": "97174b9f-f9fe-4498-b530-e8d01c2c0522", "name": "load_p1rlv444_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30f29674-3083-4da2-95e2-a1f11a7eb7f8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fc06d0ff-46e7-414c-a1a0-9fec97e1ed9a"}}}}, {"uuid": "a686f642-643e-46b3-b1c7-f36193346147", "name": "bc70b632-df4e-49f4-a0d2-9586c52f1e8e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1461342593009323, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5165512162199262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "505ad3a5-7414-4fda-b5a4-22e9cc3d8765", "name": "393488ca-8f05-47f5-baaa-e7031131f84e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a686f642-643e-46b3-b1c7-f36193346147"}}}]}, {"uuid": "0a1432fb-6cad-4f4b-901c-b36108aedbff", "name": "load_p1rlv444_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30f29674-3083-4da2-95e2-a1f11a7eb7f8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "505ad3a5-7414-4fda-b5a4-22e9cc3d8765"}}}}, {"uuid": "697c28aa-80d6-4999-95db-098093347a29", "name": "f18426f4-6aa9-4aa9-8422-6d06a64a1243_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3269645363150677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5800133371554559, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a2eef9f-d812-4a82-ba33-8a0826a6fcfd", "name": "f4587ba9-bfbe-4da6-b1be-e6563afc89e6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "697c28aa-80d6-4999-95db-098093347a29"}}}]}, {"uuid": "7cf88d07-693e-4f44-9c68-da32cee2458a", "name": "load_p1rlv445_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d665758-71e1-4478-b39d-671f78f623e5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a2eef9f-d812-4a82-ba33-8a0826a6fcfd"}}}}, {"uuid": "93de3409-9b99-43c0-b071-432c2d9c2e37", "name": "32d226d5-0ef5-4eb9-8b29-fea2daef4505_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3269645363150677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5800133371554559, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0242c41e-10a4-437a-846a-b1ac803df3a3", "name": "212a1fef-e01a-457b-b81f-5e7385b6de57", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "93de3409-9b99-43c0-b071-432c2d9c2e37"}}}]}, {"uuid": "17ce9b5b-47c0-4564-8cd7-2905a8590713", "name": "load_p1rlv445_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d665758-71e1-4478-b39d-671f78f623e5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0242c41e-10a4-437a-846a-b1ac803df3a3"}}}}, {"uuid": "b1ebaca0-d070-46a2-baf4-37aa4cc91c98", "name": "c13b909a-5ec0-4470-982d-8d00eef6dd35_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.810132764673673, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.37076490271254653, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "47e98740-9410-49dc-bed7-d38f767046cf", "name": "626559fd-4634-49fc-8d96-151af2878a5e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b1ebaca0-d070-46a2-baf4-37aa4cc91c98"}}}]}, {"uuid": "9ee773f3-ecf1-4c59-b54e-bb9eedf8e0c5", "name": "load_p1rlv446_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acce3105-f519-491c-921a-df1294795742"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "47e98740-9410-49dc-bed7-d38f767046cf"}}}}, {"uuid": "37f518c3-137c-4023-b8ad-36e6b4dd34a9", "name": "585e9a13-274d-4cc5-bc4d-4885c2b50332_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.810132764673673, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.37076490271254653, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e968e1ca-f469-47e8-bf0f-725ddeedea33", "name": "8e71cb50-7cce-49c4-8217-d40239f37d78", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "37f518c3-137c-4023-b8ad-36e6b4dd34a9"}}}]}, {"uuid": "3bfe5804-c45b-43d3-829e-c49058179c31", "name": "load_p1rlv446_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acce3105-f519-491c-921a-df1294795742"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e968e1ca-f469-47e8-bf0f-725ddeedea33"}}}}, {"uuid": "cbbf026e-f948-4aed-be19-605541ad1420", "name": "cd7abfd6-7f0e-4a14-b7e3-ce91d3553671_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.606460911827677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.1012105340517033, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "80ccb464-d7bc-45ce-88ae-1568eed1f7df", "name": "5b26b15c-9edc-40c4-993a-8e67a69dec14", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cbbf026e-f948-4aed-be19-605541ad1420"}}}]}, {"uuid": "adcf1f3d-8e55-4089-8a27-4424b2d292dd", "name": "load_p1rlv447_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "042873fa-10df-4de0-a040-ac429b8bf7d9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "80ccb464-d7bc-45ce-88ae-1568eed1f7df"}}}}, {"uuid": "17cc2108-3c91-4142-9885-a7ab233506b5", "name": "7a1dda18-7e0c-4e50-aad9-429562d6d099_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.606460911827677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.1012105340517033, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dbe26070-4c19-4de3-8c5d-ee36a45cb679", "name": "d4c7bb47-ea9a-4416-a135-b1e974019adc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "17cc2108-3c91-4142-9885-a7ab233506b5"}}}]}, {"uuid": "3be041c5-000b-4d30-b42f-7219011ace44", "name": "load_p1rlv447_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "042873fa-10df-4de0-a040-ac429b8bf7d9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dbe26070-4c19-4de3-8c5d-ee36a45cb679"}}}}, {"uuid": "0302377c-9560-40df-b94e-7d47958e7e2f", "name": "36e137af-4506-41c5-88d4-13cc37413ad7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.241801892330501, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.45459688794228914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b76e2b4d-44de-488e-a2b0-fe0ab4d9fc6a", "name": "0fc2a879-4524-4454-8d0c-af1cd2f4ddc9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0302377c-9560-40df-b94e-7d47958e7e2f"}}}]}, {"uuid": "eab61bbb-5785-4d80-921a-cc241f8d8ffb", "name": "load_p1rlv448_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bb83d65-630d-4f1d-8e3d-8937a5a05524"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b76e2b4d-44de-488e-a2b0-fe0ab4d9fc6a"}}}}, {"uuid": "04c1ee12-8cdc-4a0f-871d-eb504a594131", "name": "f9a9fd1c-da0f-499b-8ed9-4e1e75ba09bc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.241801892330501, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.45459688794228914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a9d755ea-888b-484b-b184-f574920bbd11", "name": "31f55e2b-c26e-419e-a2d2-82d1ffb69f9a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "04c1ee12-8cdc-4a0f-871d-eb504a594131"}}}]}, {"uuid": "01eeac4e-7618-4bd3-b15c-a531cc23386a", "name": "load_p1rlv448_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bb83d65-630d-4f1d-8e3d-8937a5a05524"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a9d755ea-888b-484b-b184-f574920bbd11"}}}}, {"uuid": "f6f07fed-ee95-42bb-9b2f-99cdbcc98836", "name": "6c3bbabf-0f96-4ad5-baf6-a8243db13b5f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.290770207979584, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.15121699106508624, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a3c85719-80c2-4257-aadc-5358eebfe11b", "name": "fafbfad2-39cd-4a47-8588-f97146a2a530", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f6f07fed-ee95-42bb-9b2f-99cdbcc98836"}}}]}, {"uuid": "ba3cad7c-886c-4aec-bac5-7664880c8a25", "name": "load_p1rlv449_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "753035df-8705-48eb-92b3-c4bef603b66b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a3c85719-80c2-4257-aadc-5358eebfe11b"}}}}, {"uuid": "9fe52978-caa5-4c34-854e-f4eb88ec571f", "name": "c5e484af-10f2-4d14-882c-a3305f0f92d8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.290770207979584, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.15121699106508624, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "16df0960-22c5-4e53-895d-1586ecbecb14", "name": "6abf24ac-9d6c-4c58-a7a0-73fcf29fa5d6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9fe52978-caa5-4c34-854e-f4eb88ec571f"}}}]}, {"uuid": "fd3f66c4-070f-4567-8f8f-046fd7fc7953", "name": "load_p1rlv449_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "753035df-8705-48eb-92b3-c4bef603b66b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "16df0960-22c5-4e53-895d-1586ecbecb14"}}}}, {"uuid": "bddf4021-0bda-4b02-8584-83cb52ea6df6", "name": "573539e9-7e06-4a2e-8d2e-c61eecc3042d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.074192704000552, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.129078804753558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6529e2b5-4cec-4e70-ae8e-0fb735fc49c7", "name": "e9bfea5c-766e-4e0f-98cd-af636b88abd9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bddf4021-0bda-4b02-8584-83cb52ea6df6"}}}]}, {"uuid": "f56e4e94-fe53-4378-9421-65c4497ea5d9", "name": "load_p1rlv452_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb46f1ae-0cdb-45d1-b389-639cdf345f8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6529e2b5-4cec-4e70-ae8e-0fb735fc49c7"}}}}, {"uuid": "8baa3ae2-948d-4504-8e5f-96544b5bff7d", "name": "0704b8cb-b9f0-413b-844a-b8232935edf0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.074192704000552, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.129078804753558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "57d1c980-b6f4-4f7b-9cbe-9be88495d841", "name": "a302670d-46d5-4562-bd79-162909ef155a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8baa3ae2-948d-4504-8e5f-96544b5bff7d"}}}]}, {"uuid": "33892645-c73d-42da-9133-c45f150cfe05", "name": "load_p1rlv452_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb46f1ae-0cdb-45d1-b389-639cdf345f8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "57d1c980-b6f4-4f7b-9cbe-9be88495d841"}}}}, {"uuid": "99f3b56a-cb1e-43d1-bd43-4c73175033c1", "name": "cc4294ad-1de6-403b-b2b5-71056cc2f3fe_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2596055778412756, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4460523908595607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9b0b62d1-9bd0-450b-9454-3dae35c5bb13", "name": "66d2645b-5405-436b-a633-5b7d8b80ad2c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "99f3b56a-cb1e-43d1-bd43-4c73175033c1"}}}]}, {"uuid": "26f59976-54ab-440b-a03f-d9ddaecc9239", "name": "load_p1rlv453_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6a8a3c7-5165-48b7-8233-30d3af045442"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9b0b62d1-9bd0-450b-9454-3dae35c5bb13"}}}}, {"uuid": "7bcd775c-fb87-4ffd-be72-aa4957ceb9fc", "name": "e5e9ddd3-8c92-4393-8c95-8ff5ce52a467_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2596055778412756, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4460523908595607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "795c5ff0-765b-4d2e-84e6-b605b9f21f84", "name": "db356f00-6f24-406a-8f64-46b49003841a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7bcd775c-fb87-4ffd-be72-aa4957ceb9fc"}}}]}, {"uuid": "cd277a1a-45ef-4295-9a91-09ec9aec78d8", "name": "load_p1rlv453_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6a8a3c7-5165-48b7-8233-30d3af045442"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "795c5ff0-765b-4d2e-84e6-b605b9f21f84"}}}}, {"uuid": "af2dfd1e-d3d1-4abc-8e58-088d954abeb0", "name": "0c037c26-3125-41e7-8397-dae2b1fc74c8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4699462180170992, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3815978523472859, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bb461309-e0cf-4887-9031-9ac78ac63cb4", "name": "2b0e6d4f-78ed-4a16-b402-7009875520fe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "af2dfd1e-d3d1-4abc-8e58-088d954abeb0"}}}]}, {"uuid": "d51fe97e-f43a-4667-a760-d9a9eed3d4b7", "name": "load_p1rlv454_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3493b0ed-43a2-4602-a7ad-a817331c9d8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bb461309-e0cf-4887-9031-9ac78ac63cb4"}}}}, {"uuid": "5cad70c7-ac45-4b90-a5f3-78e154cc8341", "name": "dd000ba0-8605-43d7-8515-81e634f62533_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4699462180170992, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3815978523472859, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fc6fb7d6-1359-476d-97b1-20bd867f3a18", "name": "6598e321-ea38-42c7-a989-a50e7ae0ac62", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5cad70c7-ac45-4b90-a5f3-78e154cc8341"}}}]}, {"uuid": "215467aa-97f1-4ba5-8bcf-bad6a898e4f8", "name": "load_p1rlv454_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3493b0ed-43a2-4602-a7ad-a817331c9d8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fc6fb7d6-1359-476d-97b1-20bd867f3a18"}}}}, {"uuid": "c1266b4d-e8a3-48a2-9297-e10fe963cf5e", "name": "29fc98bb-2656-41f5-ad5e-1431eb3fb30b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5202593896091736, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6973445820856009, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "96cd17e7-f798-45b1-8136-6e07bd96d687", "name": "2bbad14f-f795-44e7-8b67-3c821ac4df2b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c1266b4d-e8a3-48a2-9297-e10fe963cf5e"}}}]}, {"uuid": "f0320455-ed71-4eeb-b7cb-3891fd5c8df6", "name": "load_p1rlv455_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "552153cc-f5be-42ee-9985-9361c2e7e2a1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "96cd17e7-f798-45b1-8136-6e07bd96d687"}}}}, {"uuid": "4a5816d1-5d8a-4d59-9761-844ac1fca02d", "name": "de884caa-1c0a-4d92-9115-9f212e96e999_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5202593896091736, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6973445820856009, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "20c248bc-ee70-493f-abc6-aef541a4bb02", "name": "0837a3bd-373a-4210-b7ca-d37bd7aac7cd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4a5816d1-5d8a-4d59-9761-844ac1fca02d"}}}]}, {"uuid": "e503e50d-78e4-4333-bd39-09478619af1c", "name": "load_p1rlv455_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "552153cc-f5be-42ee-9985-9361c2e7e2a1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "20c248bc-ee70-493f-abc6-aef541a4bb02"}}}}, {"uuid": "6d04a185-16bf-47d6-9f92-deb00c1096f4", "name": "78026fdd-52f3-43d6-bb7e-c54fee37d7d9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.664483224984605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9538644530515166, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "704246ad-9aa3-4b64-8adc-72cdeefbf279", "name": "450c3cf4-a57c-4818-9ed7-c910ce08ddae", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6d04a185-16bf-47d6-9f92-deb00c1096f4"}}}]}, {"uuid": "04d7b81b-9fb7-418b-b8ae-51d232702c4d", "name": "load_p1rlv456_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85f0d94e-c096-4d53-ae05-f0dc59f73d02"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "704246ad-9aa3-4b64-8adc-72cdeefbf279"}}}}, {"uuid": "f8906971-5101-4f75-a721-5b7cc3867d5d", "name": "a6fbb3e3-65df-4eaf-8ea6-1ce7d4ce30c2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.664483224984605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9538644530515166, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bda896e9-bf5f-4151-aea7-4cb9f002a0f3", "name": "0305c1c2-bb42-495e-b37e-c56caa95ae85", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8906971-5101-4f75-a721-5b7cc3867d5d"}}}]}, {"uuid": "b3693e19-7baa-4575-ab10-58ea8a3303e5", "name": "load_p1rlv456_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85f0d94e-c096-4d53-ae05-f0dc59f73d02"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bda896e9-bf5f-4151-aea7-4cb9f002a0f3"}}}}, {"uuid": "07259dfc-789d-432d-b8a8-7201249a0d4a", "name": "f9e0814c-a28f-4273-af2f-71fc3f0ddb91_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.001928314210379, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4572901775510755, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8e28387d-892b-4c4a-9bfc-5d99ddc34b9d", "name": "5ade5781-13d3-48eb-92c9-b1b1b675db52", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "07259dfc-789d-432d-b8a8-7201249a0d4a"}}}]}, {"uuid": "6396f646-0b7b-4db8-905b-1aaa0fc529ac", "name": "load_p1rlv457_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6278f6ee-7332-4de8-9d2c-83bb637f489f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8e28387d-892b-4c4a-9bfc-5d99ddc34b9d"}}}}, {"uuid": "eef9909b-7dfb-4201-ba64-64972a7510b2", "name": "659fa35c-9f5f-4372-8a85-75793de72145_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.001928314210379, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4572901775510755, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f0beaee8-0dff-41be-8079-7008b9f38793", "name": "39099389-cdfc-4a1f-816c-c93dfa19271a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eef9909b-7dfb-4201-ba64-64972a7510b2"}}}]}, {"uuid": "cd573da9-d64f-4198-8f46-34a079f6602d", "name": "load_p1rlv457_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6278f6ee-7332-4de8-9d2c-83bb637f489f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f0beaee8-0dff-41be-8079-7008b9f38793"}}}}, {"uuid": "c788b54e-b76d-42bb-b55d-f9517ddd652b", "name": "fdfcd836-32ea-4c57-a20d-a8d0068a30d3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.24613321897865, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9528039237137753, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f06e3d1c-158f-416f-a682-7a7e66916b4c", "name": "2600ca77-2070-413e-9efb-f80804cb32fe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c788b54e-b76d-42bb-b55d-f9517ddd652b"}}}]}, {"uuid": "33524da1-876d-4466-9090-b54091e6186f", "name": "load_p1rlv458_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec66e302-748d-4300-ba65-719de0a906bb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f06e3d1c-158f-416f-a682-7a7e66916b4c"}}}}, {"uuid": "00b54568-a399-4168-b6b2-108bddace79b", "name": "3684c6ad-023a-42d3-be59-ed89bf121656_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.24613321897865, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9528039237137753, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2a2dfb4e-141c-4d8d-a7de-4dad5ba04eb7", "name": "05729729-e11a-4080-8e71-641b55183fda", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "00b54568-a399-4168-b6b2-108bddace79b"}}}]}, {"uuid": "c1a77fe8-1909-4bc7-ae97-94b06c52435b", "name": "load_p1rlv458_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec66e302-748d-4300-ba65-719de0a906bb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2a2dfb4e-141c-4d8d-a7de-4dad5ba04eb7"}}}}, {"uuid": "a03db4c5-93b6-4bd5-8db4-6a563dcdb30e", "name": "6aa860cd-622e-4014-af12-abc266d26b30_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.502751049099443, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7555421856436744, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ba26bf17-ab63-4273-a0bb-faf9bad4de4c", "name": "717ae0b6-4d1f-464a-a299-f077fbb35b0a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a03db4c5-93b6-4bd5-8db4-6a563dcdb30e"}}}]}, {"uuid": "f23ab323-54c8-435f-b1fd-8e60cf8cd52c", "name": "load_p1rlv459_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c112196-bcbc-41bc-99a9-f3657c335c7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ba26bf17-ab63-4273-a0bb-faf9bad4de4c"}}}}, {"uuid": "8ef17114-2bb3-45d9-841e-3bd09e0e7c5f", "name": "90727a7c-dec7-417b-b2f0-57aab2169b89_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.502751049099443, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7555421856436744, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3a502be6-0db3-4667-b815-6a8ee1a44e72", "name": "4a9ecb98-9a3c-4d9b-a503-5e0e697e9acd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ef17114-2bb3-45d9-841e-3bd09e0e7c5f"}}}]}, {"uuid": "f800f59e-b573-4dfb-8d51-8b8de0ced0be", "name": "load_p1rlv459_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c112196-bcbc-41bc-99a9-f3657c335c7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3a502be6-0db3-4667-b815-6a8ee1a44e72"}}}}, {"uuid": "e36a1032-84f7-47fb-99f7-ba68f0b1c98f", "name": "f9131d78-d7bf-409d-804a-fc58fdaac44d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8202631342288826, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.26720803692022926, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0cf0611e-cc09-4f7e-a2bd-4fd7c593d2f4", "name": "0e0565b4-bd83-4f37-81b9-95f041a12d3e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e36a1032-84f7-47fb-99f7-ba68f0b1c98f"}}}]}, {"uuid": "bb55e834-c0df-4bda-8242-dcccf3fe15eb", "name": "load_p1rlv460_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76b212f9-2e27-4064-a2c5-079786afb1d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0cf0611e-cc09-4f7e-a2bd-4fd7c593d2f4"}}}}, {"uuid": "2b4a72cb-bb3d-4bc4-bd92-709af163a462", "name": "928a7425-e29f-43af-abfa-86f7dc12bd20_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8202631342288826, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.26720803692022926, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "86cc4222-c03b-482f-90aa-46d44bb2aeef", "name": "9df527a7-87df-4771-bbfc-7d7d2a3f0eff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2b4a72cb-bb3d-4bc4-bd92-709af163a462"}}}]}, {"uuid": "3071b825-5459-4be8-8b76-f333c316f4c7", "name": "load_p1rlv460_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76b212f9-2e27-4064-a2c5-079786afb1d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "86cc4222-c03b-482f-90aa-46d44bb2aeef"}}}}, {"uuid": "1681dc0a-7a40-434e-8dba-1f19db51925a", "name": "bbe8984b-a62b-45d1-b9f7-12adcba1965e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4622944887503224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10483650830237357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5152946d-17ad-452a-8d50-3ab5b14d25ec", "name": "c3dc8d70-ae93-40ba-b524-b4d321e9f59f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1681dc0a-7a40-434e-8dba-1f19db51925a"}}}]}, {"uuid": "77243974-dd20-4014-b17d-913466af3faf", "name": "load_p1rlv461_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76dd0f1b-4109-4707-a547-f0ab1b6e148f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5152946d-17ad-452a-8d50-3ab5b14d25ec"}}}}, {"uuid": "7578199c-24c3-47ee-8412-ae5e4b092da4", "name": "5bdbdf12-504c-40f1-947d-aa28ee8f89ae_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4622944887503224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10483650830237357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1af4b0d4-e28b-424b-9db1-b7e5869961ab", "name": "6beb972c-9312-4ba8-be20-e79b4ada60e2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7578199c-24c3-47ee-8412-ae5e4b092da4"}}}]}, {"uuid": "a432c673-e52c-41e5-9676-f3fb7b3a04af", "name": "load_p1rlv461_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76dd0f1b-4109-4707-a547-f0ab1b6e148f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1af4b0d4-e28b-424b-9db1-b7e5869961ab"}}}}, {"uuid": "74ed2102-5079-49a3-961d-c854ee51c3cf", "name": "70864144-ffa6-4574-9ecc-4a5c7a3a4b29_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3786182488338723, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5359363058124609, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8b5d7657-81f0-47be-bf22-bebb1d57940b", "name": "caf9718a-fa65-4a51-9361-02be5286f5a6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "74ed2102-5079-49a3-961d-c854ee51c3cf"}}}]}, {"uuid": "f07a0d15-0adc-40e9-aa3c-e16810c2f41e", "name": "load_p1rlv462_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9176da24-7eb5-4b0b-99dd-886c3f974798"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8b5d7657-81f0-47be-bf22-bebb1d57940b"}}}}, {"uuid": "144dbe08-6967-4a00-8ff3-45902a02f650", "name": "8c97b50e-20d1-4d7f-9104-ac19c7d6d5c7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3786182488338723, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5359363058124609, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eb331271-5ef8-45ee-98a5-5e50fea9bb53", "name": "ead2c979-3975-4844-801f-17fa2f40abd4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "144dbe08-6967-4a00-8ff3-45902a02f650"}}}]}, {"uuid": "dbb406a5-e5db-4542-bab9-85656860b5cc", "name": "load_p1rlv462_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9176da24-7eb5-4b0b-99dd-886c3f974798"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eb331271-5ef8-45ee-98a5-5e50fea9bb53"}}}}, {"uuid": "c9b8b2db-fc98-4b73-9372-7b7f56fc06fd", "name": "d38aa64b-6817-4902-b4af-29d0405521ac_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.746284303820433, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6724067157838972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8affc3e7-cc33-47aa-8b64-46f8752acfd2", "name": "832568a2-1b70-43bd-b287-a8ecc7b6008e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9b8b2db-fc98-4b73-9372-7b7f56fc06fd"}}}]}, {"uuid": "bbb2b72b-01b7-4567-a526-08186d132dff", "name": "load_p1rlv463_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff9d9cca-1878-478d-a190-b58c9098f13e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8affc3e7-cc33-47aa-8b64-46f8752acfd2"}}}}, {"uuid": "8493882e-5fe4-4431-b91d-23f766fb3835", "name": "2b44ede7-f0d3-40cf-9ef5-3911382d78f7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.746284303820433, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6724067157838972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7f0a4bf9-4787-4faf-b94f-27e068b9fd23", "name": "ae16dc1f-98a8-471a-8950-fc2f7856f811", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8493882e-5fe4-4431-b91d-23f766fb3835"}}}]}, {"uuid": "0692a8dd-5767-4faa-8ed2-22f06e6818a5", "name": "load_p1rlv463_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff9d9cca-1878-478d-a190-b58c9098f13e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7f0a4bf9-4787-4faf-b94f-27e068b9fd23"}}}}, {"uuid": "90b9c581-1af5-4535-a4e6-5c0bb62f15cd", "name": "589c50c8-66ad-464a-b072-b39b7b629c8e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6697995975485909, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.41657408993223344, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bdff3310-45b0-4cd2-9fbb-76ac2646ed22", "name": "a584c625-4eaf-4447-a60f-da33dbd2aad3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "90b9c581-1af5-4535-a4e6-5c0bb62f15cd"}}}]}, {"uuid": "0ac20aca-a1b8-4ca7-8af5-c18603f14c87", "name": "load_p1rlv464_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "895d0235-3ee6-4f06-9978-9d615d721ebd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bdff3310-45b0-4cd2-9fbb-76ac2646ed22"}}}}, {"uuid": "045e93db-d4b2-4939-8648-121b125682a9", "name": "78c10fdf-2c51-4a7e-b931-5f4249b795a5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6697995975485909, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.41657408993223344, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1836608f-4a1a-4787-a25b-a3e6d90cf0fb", "name": "40119705-7971-4e0c-9403-92879dc6f264", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "045e93db-d4b2-4939-8648-121b125682a9"}}}]}, {"uuid": "70712bd9-cf0d-4d57-b077-5f8c62d2c443", "name": "load_p1rlv464_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "895d0235-3ee6-4f06-9978-9d615d721ebd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1836608f-4a1a-4787-a25b-a3e6d90cf0fb"}}}}, {"uuid": "23f7b572-b420-4566-a98c-b0957a8d3705", "name": "5540f6f1-1e88-429e-8a19-7fbed822563b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.39658717665728, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7677987041236869, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "231541f9-de2a-43fe-8f6d-b1fa16116d70", "name": "68e7af5f-ee63-47a5-9fbc-85802e26b14b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "23f7b572-b420-4566-a98c-b0957a8d3705"}}}]}, {"uuid": "4dbb057b-7a4c-46b0-b651-b7953221ee68", "name": "load_p1rlv474_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e589527-d388-4364-87d2-2f4af1a14509"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "231541f9-de2a-43fe-8f6d-b1fa16116d70"}}}}, {"uuid": "a1f1dbc9-434a-4bda-a3be-744652481039", "name": "c1626b19-390a-438b-bb22-3a67618e84e3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.39658717665728, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7677987041236869, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e05045f9-527b-4c22-b442-7e07341cff95", "name": "16229ae1-0f2c-49a1-b497-ecb55f58586d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a1f1dbc9-434a-4bda-a3be-744652481039"}}}]}, {"uuid": "a2b46400-933c-4daf-8d8a-0db79c8d68c8", "name": "load_p1rlv474_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e589527-d388-4364-87d2-2f4af1a14509"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e05045f9-527b-4c22-b442-7e07341cff95"}}}}, {"uuid": "abf3daaf-3351-4985-aa87-859e07d1038e", "name": "3aa690da-241d-46f3-bb64-0117330bb2c2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0286208645240644, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.052486030755511705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "55898de9-b406-4e16-9444-fc188a12b038", "name": "a5533b53-cc31-4481-93a7-e7a1a2fe8c05", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "abf3daaf-3351-4985-aa87-859e07d1038e"}}}]}, {"uuid": "043b62da-c1eb-4c2e-98d3-267b9c8c764c", "name": "load_p1rlv480_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb55ec0b-b6f7-48a7-8dae-dda95fc34499"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "55898de9-b406-4e16-9444-fc188a12b038"}}}}, {"uuid": "fb39a764-5af3-48da-9038-0a882971a76f", "name": "ae6d6173-39cd-4f95-a615-43c904298ad5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0286208645240644, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.052486030755511705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d268605c-e163-4f4e-a55d-89769662b069", "name": "1ce324fd-d025-41ff-b7a3-c63373a72816", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fb39a764-5af3-48da-9038-0a882971a76f"}}}]}, {"uuid": "f055d64c-5f91-48e8-a3a0-3e00176d588a", "name": "load_p1rlv480_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb55ec0b-b6f7-48a7-8dae-dda95fc34499"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d268605c-e163-4f4e-a55d-89769662b069"}}}}, {"uuid": "01d86a82-6b19-4195-af70-50b97e15278b", "name": "0ce8fcdc-7ce8-4c03-8425-b80a2e092b64_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.344060161619426, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2705527109429713, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "084a4884-2c0f-4fc8-9f28-9ef621e2d7db", "name": "df7e8996-7993-4e74-86f4-57f32eec8344", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "01d86a82-6b19-4195-af70-50b97e15278b"}}}]}, {"uuid": "9d37f739-515f-41ac-95e3-b2c68f6180f2", "name": "load_p1rlv481_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d9e77ad-42c6-4413-96e6-debfed3c442a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "084a4884-2c0f-4fc8-9f28-9ef621e2d7db"}}}}, {"uuid": "55980176-93de-43e5-b013-471374eb1320", "name": "635de8d9-6a09-4e38-b23f-1f821810a8c3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.344060161619426, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2705527109429713, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4ff8aadf-bf74-4264-afc9-654c2b1a74d2", "name": "0a1e8ade-aee1-422e-8547-341980381f49", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "55980176-93de-43e5-b013-471374eb1320"}}}]}, {"uuid": "f6153836-4bed-404c-bdf1-63eb9f24e1f9", "name": "load_p1rlv481_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d9e77ad-42c6-4413-96e6-debfed3c442a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4ff8aadf-bf74-4264-afc9-654c2b1a74d2"}}}}, {"uuid": "aa79d731-94a7-48dd-8d59-5d7e0353e921", "name": "f68c64e8-6ce9-4752-b6f1-f633305cc042_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7771517670040275, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8838563298920215, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "346e1f94-ef53-4328-85d8-3e731cbed0bc", "name": "b543513b-8bbd-4ee6-af00-6b2c45657b65", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aa79d731-94a7-48dd-8d59-5d7e0353e921"}}}]}, {"uuid": "5330f48f-076b-49f1-82a8-aa95d814afc0", "name": "load_p1rlv482_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d4b708f-cc15-4ee3-87e0-4d26fec02f1e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "346e1f94-ef53-4328-85d8-3e731cbed0bc"}}}}, {"uuid": "fa809bda-ab1f-468c-a1c0-00ae4155b327", "name": "1df30ee9-3d2f-4c8e-b8f7-1c8c8560c726_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7771517670040275, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8838563298920215, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "61d43de4-349e-45e0-9fad-ca8b5cb8a96b", "name": "222bd2f6-8ef5-451f-99d4-e12b6a9b7b18", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fa809bda-ab1f-468c-a1c0-00ae4155b327"}}}]}, {"uuid": "d784bc94-505d-48cc-9eb3-5d431ef40017", "name": "load_p1rlv482_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d4b708f-cc15-4ee3-87e0-4d26fec02f1e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "61d43de4-349e-45e0-9fad-ca8b5cb8a96b"}}}}, {"uuid": "1825ac5b-af7c-47f2-9768-71fb16fe3580", "name": "7e3d9b34-b59b-4b5f-80c0-4b6df9e76ec6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.028781788264419, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6709073147144231, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "75baf9e4-7868-4e67-b246-614b1840a719", "name": "1027a59c-2df8-4068-94f2-2a7dce473b00", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1825ac5b-af7c-47f2-9768-71fb16fe3580"}}}]}, {"uuid": "5f58554e-ae27-4ee3-b8ce-2ce2b4da05e1", "name": "load_p1rlv483_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d059a618-6f09-404b-b1a0-0e7aa0c55c45"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "75baf9e4-7868-4e67-b246-614b1840a719"}}}}, {"uuid": "3bc1d7e1-1784-42d6-8c39-e8e06455df71", "name": "4a61aa61-fe56-4b0f-9a5f-2f33c303efd8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.028781788264419, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6709073147144231, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f0079fd6-6054-417f-8616-d1e9750b4fae", "name": "b2202614-2c1e-42be-9eda-0fc84316a583", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3bc1d7e1-1784-42d6-8c39-e8e06455df71"}}}]}, {"uuid": "9a558047-9b01-41d0-848f-110b5dc5a875", "name": "load_p1rlv483_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d059a618-6f09-404b-b1a0-0e7aa0c55c45"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f0079fd6-6054-417f-8616-d1e9750b4fae"}}}}, {"uuid": "7fd86059-1fb0-4850-8383-80f9c0d89b07", "name": "78b7cde0-9788-4784-bda5-b2e87c3762ce_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2cae686a-7690-4c89-87fb-f6411445c88a", "name": "4b8f45ca-515d-4011-beb3-1d7dff9174f4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7fd86059-1fb0-4850-8383-80f9c0d89b07"}}}]}, {"uuid": "0a5c43a0-66a6-47dc-a6a2-81c017f57312", "name": "load_p1rlv484_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fde62b60-c5f6-44d6-b2f2-211c21b02033"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2cae686a-7690-4c89-87fb-f6411445c88a"}}}}, {"uuid": "91f21c3a-09a1-463e-bd18-697a4cef3d1d", "name": "cae84f22-cbc8-4490-87ec-65a09cce4be7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c22693f2-4e3e-4332-90df-348f8224e354", "name": "ed9ef4a6-f1f0-4298-a291-139014d1ed1b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "91f21c3a-09a1-463e-bd18-697a4cef3d1d"}}}]}, {"uuid": "2efcaf50-890a-472b-8585-0b0aed28c88c", "name": "load_p1rlv484_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fde62b60-c5f6-44d6-b2f2-211c21b02033"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c22693f2-4e3e-4332-90df-348f8224e354"}}}}, {"uuid": "7c82752e-6238-4694-b6fc-1de01350b614", "name": "0a2fdbf3-b2e1-4e28-bda9-b206aeef6354_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1427818095792333, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033588044558321, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bede68a2-9953-41f7-81c5-67e173e1f7b5", "name": "b81a309e-cfd3-495d-8bc6-b8876ab86522", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7c82752e-6238-4694-b6fc-1de01350b614"}}}]}, {"uuid": "961d3415-4d1b-469d-ad95-d2fb2cba8f9f", "name": "load_p1rlv485_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d2c379-7e19-46c4-8c6e-533fa9db7764"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bede68a2-9953-41f7-81c5-67e173e1f7b5"}}}}, {"uuid": "c9782cba-ea23-4cc0-8eeb-ab8863e342d1", "name": "e23f1faf-8f46-47c3-9fcb-ecf840026784_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1427818095792333, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033588044558321, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2cbeff2f-e022-4b7d-84c0-a0669e5273fc", "name": "15584f6e-d34b-4bab-a9b2-27de606bf26a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9782cba-ea23-4cc0-8eeb-ab8863e342d1"}}}]}, {"uuid": "71f48568-c9c7-48f3-b31a-c98da55e2867", "name": "load_p1rlv485_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d2c379-7e19-46c4-8c6e-533fa9db7764"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2cbeff2f-e022-4b7d-84c0-a0669e5273fc"}}}}, {"uuid": "ef005c11-6613-4d1f-a3f9-ef1660f354cc", "name": "8574ce8c-c0ac-458f-b3d1-5d56ab2dfd00_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5348201699646123, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21241824123648728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f345581f-8b31-49e3-b909-744fd85f1da8", "name": "2583cce9-86fe-4153-b471-f6f480cd262f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ef005c11-6613-4d1f-a3f9-ef1660f354cc"}}}]}, {"uuid": "d781c621-8a08-4bd9-8932-b022ced80680", "name": "load_p1rlv486_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a54b2228-9e7d-4e6b-939d-ab2765454522"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f345581f-8b31-49e3-b909-744fd85f1da8"}}}}, {"uuid": "8b485a7f-3820-452a-ad3a-dbf638044106", "name": "f82bda5c-6bd7-457a-bd8d-5a3d236abcc9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5348201699646123, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21241824123648728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eb877549-0aa6-41ab-a159-3eb8f8a8d16e", "name": "7ec9eede-273c-464c-8684-5216cab393e3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8b485a7f-3820-452a-ad3a-dbf638044106"}}}]}, {"uuid": "7c85c75e-9c64-411f-b5f6-fc3e067e7dad", "name": "load_p1rlv486_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a54b2228-9e7d-4e6b-939d-ab2765454522"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eb877549-0aa6-41ab-a159-3eb8f8a8d16e"}}}}, {"uuid": "37587ae2-c7e3-4b8e-bc53-2e1bd69f1b94", "name": "dbb8d51a-9d04-47a0-8808-9d984c3f20b9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.735884899619907, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7862059386133167, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2a04339c-e49e-4079-8dfa-72d503319bb3", "name": "ed24707c-33ab-4e77-a007-3fc31e829c35", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "37587ae2-c7e3-4b8e-bc53-2e1bd69f1b94"}}}]}, {"uuid": "caa60bdc-63e7-41df-9f56-3480e49958e3", "name": "load_p1rlv487_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2d5799-907e-46fd-a389-120aea352775"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2a04339c-e49e-4079-8dfa-72d503319bb3"}}}}, {"uuid": "635823f5-2af2-4722-8628-1c8309c068f0", "name": "53db1c7b-b1ea-4eda-804a-4739b66213c7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.735884899619907, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7862059386133167, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "785d5de7-2553-4f05-8d72-6e79c2b533a0", "name": "de29166c-4d19-4cc6-a3ba-2cfc74254d6d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "635823f5-2af2-4722-8628-1c8309c068f0"}}}]}, {"uuid": "492910aa-850c-43d9-8fd0-a8b444dd4d33", "name": "load_p1rlv487_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2d5799-907e-46fd-a389-120aea352775"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "785d5de7-2553-4f05-8d72-6e79c2b533a0"}}}}, {"uuid": "114a88fc-4cce-4a85-8877-b8af701eb28b", "name": "f66e6768-368c-4b9a-93d1-5bfa67109daa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4382677398578904, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21115535117680156, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "15e403be-c270-4b31-b9ee-89554f382fd3", "name": "3905f176-648c-47db-9614-82224653a856", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "114a88fc-4cce-4a85-8877-b8af701eb28b"}}}]}, {"uuid": "119a4e4a-f6be-4b55-9900-87c023e626f3", "name": "load_p1rlv523_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97c38794-7c60-4ff8-b09b-7503c9604409"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "15e403be-c270-4b31-b9ee-89554f382fd3"}}}}, {"uuid": "494fd173-51a7-443c-8d92-b653a872f414", "name": "343b7015-d5e0-4d33-9063-52885cdf5728_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4382677398578904, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21115535117680156, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c61863b-4b03-449a-ba74-5a0b3b6f1240", "name": "517586d4-15d7-438c-865e-10fa3790e5ad", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "494fd173-51a7-443c-8d92-b653a872f414"}}}]}, {"uuid": "42101e58-1bef-43a2-8cf3-8b619ff04974", "name": "load_p1rlv523_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97c38794-7c60-4ff8-b09b-7503c9604409"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c61863b-4b03-449a-ba74-5a0b3b6f1240"}}}}, {"uuid": "44f33879-a83f-42d3-b0fd-b054eebfa36c", "name": "d5a8bbba-4bf9-4548-b809-990af5652257_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0716401691896973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6949594139700135, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b670fe47-e049-4a45-bd32-37a9bddc3c4a", "name": "c20e5090-9efa-4101-9164-97e4f547dc7b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "44f33879-a83f-42d3-b0fd-b054eebfa36c"}}}]}, {"uuid": "023c8818-27f6-42ae-a0a0-75b5b12371d4", "name": "load_p1rlv524_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bef074be-aac4-4d82-a832-641729756802"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b670fe47-e049-4a45-bd32-37a9bddc3c4a"}}}}, {"uuid": "3eaf7dfa-6b10-49c8-9220-412dd0c53f54", "name": "b174c88c-0b68-4811-a183-e2455e7deccd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0716401691896973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6949594139700135, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7dd02363-2c3f-4a2d-b42a-cf75c83efe12", "name": "babb8a4d-c0a4-4183-bfb7-5f5a6f2d9682", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3eaf7dfa-6b10-49c8-9220-412dd0c53f54"}}}]}, {"uuid": "7490587f-d2a9-4d03-b135-bf1f15912727", "name": "load_p1rlv524_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bef074be-aac4-4d82-a832-641729756802"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7dd02363-2c3f-4a2d-b42a-cf75c83efe12"}}}}, {"uuid": "0daa0bde-626f-4c61-91dc-fd9fcbd0228f", "name": "59d87379-9909-4561-9fe0-803c1cc97921_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6848010607962993, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6615616037111118, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "668bb1d4-8d20-4fc2-b12a-c853b2093b6c", "name": "ef894c10-fdff-4acf-8a4f-28340bd89565", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0daa0bde-626f-4c61-91dc-fd9fcbd0228f"}}}]}, {"uuid": "89affe1d-df30-4472-aa79-d9d41a960af9", "name": "load_p1rlv525_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a42f8b99-82c6-4c90-81ea-6ccb38eacfab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "668bb1d4-8d20-4fc2-b12a-c853b2093b6c"}}}}, {"uuid": "eceeb9ce-cae8-464e-a1dd-f974d4982328", "name": "da7affbb-c986-4a59-aebe-0921c814e735_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6848010607962993, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6615616037111118, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "827c6e55-1c05-4aec-977d-63675c508fce", "name": "0c6e6671-1359-4d87-912d-0245395bea05", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eceeb9ce-cae8-464e-a1dd-f974d4982328"}}}]}, {"uuid": "565dc000-ec57-49d2-b399-cdc496915202", "name": "load_p1rlv525_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a42f8b99-82c6-4c90-81ea-6ccb38eacfab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "827c6e55-1c05-4aec-977d-63675c508fce"}}}}, {"uuid": "6fce8211-ec65-4b35-b79a-3e48952231d3", "name": "3c91c04b-92ea-45f7-9066-7c4023db5805_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9444657359992037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.058006608995704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4c12a34f-4cc3-44ff-b6a1-a2d2e06a2d01", "name": "5e5d11ea-47a7-4336-913a-e6e84156ba69", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6fce8211-ec65-4b35-b79a-3e48952231d3"}}}]}, {"uuid": "702b22c3-6391-4c00-b2a0-213473b1de53", "name": "load_p1rlv526_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ab8e220-faf9-4108-80f8-22d2fe326c3d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4c12a34f-4cc3-44ff-b6a1-a2d2e06a2d01"}}}}, {"uuid": "8612b553-2a6f-4eb5-95d6-19616c0c0001", "name": "1eac6aa3-3aa4-4f02-9e94-8b3f243b0661_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9444657359992037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.058006608995704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d30d2b5d-97a4-4bcd-8926-9437ae9121e2", "name": "2d8fbce5-1be7-41ca-87ed-b35b6f047dba", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8612b553-2a6f-4eb5-95d6-19616c0c0001"}}}]}, {"uuid": "f25a304e-9871-4686-8346-4e54947de4a3", "name": "load_p1rlv526_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ab8e220-faf9-4108-80f8-22d2fe326c3d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d30d2b5d-97a4-4bcd-8926-9437ae9121e2"}}}}, {"uuid": "c4adf770-4bf0-4ff9-b5e8-a2c0b0b0ed8f", "name": "59be0bf8-dd2b-4ee8-86ff-94aae3288264_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6722127407962883, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033140171384262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a6bdab56-e0b0-4621-8573-17afc2217e60", "name": "72ac885e-4a24-491b-bc5f-2df60f7c5985", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c4adf770-4bf0-4ff9-b5e8-a2c0b0b0ed8f"}}}]}, {"uuid": "1f909f54-5f67-4499-805b-268740afd001", "name": "load_p1rlv531_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32a1d9d7-31c7-4def-88d4-e4d41bd21572"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a6bdab56-e0b0-4621-8573-17afc2217e60"}}}}, {"uuid": "d0306536-ef63-46b5-8ad7-b0c2012c02ce", "name": "e6f65fcf-9b46-4b85-b626-363e8e3abf2c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6722127407962883, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033140171384262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a5029a49-6811-4590-9b37-08466159575e", "name": "8ba2dbc3-975d-4a74-9ad2-aab7450cacc3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d0306536-ef63-46b5-8ad7-b0c2012c02ce"}}}]}, {"uuid": "d29693fc-93cc-4dcb-a81e-ec915a22a887", "name": "load_p1rlv531_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32a1d9d7-31c7-4def-88d4-e4d41bd21572"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a5029a49-6811-4590-9b37-08466159575e"}}}}, {"uuid": "ff1ce328-5ff0-4a6a-8cc3-720b36e308db", "name": "3901e228-d7d3-4c2b-9623-61fcdd03d1d2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.813063869628266, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3555509200852155, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aa62e060-7c3f-4658-a5bb-6ac27d8eab7e", "name": "df21c81a-f687-4bfe-9a36-e095194a10cf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ff1ce328-5ff0-4a6a-8cc3-720b36e308db"}}}]}, {"uuid": "1bf2ee86-4b3a-4a51-bd37-3c02cc5b2eb2", "name": "load_p1rlv532_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1362feeb-2e2c-4dd1-9f49-239c952c6120"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aa62e060-7c3f-4658-a5bb-6ac27d8eab7e"}}}}, {"uuid": "2d4d05d7-da58-4665-ad42-9d5aaf1c1cc8", "name": "c15b620e-3633-49f2-946b-5e9f3ff7ee89_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.813063869628266, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3555509200852155, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f2a566e1-d88c-4f40-93e4-eb51f9da04d1", "name": "99fd0bef-ba99-4d29-ab3f-d0833baaa501", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2d4d05d7-da58-4665-ad42-9d5aaf1c1cc8"}}}]}, {"uuid": "4bbb646b-f5e5-434a-9150-ae55074d0217", "name": "load_p1rlv532_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1362feeb-2e2c-4dd1-9f49-239c952c6120"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f2a566e1-d88c-4f40-93e4-eb51f9da04d1"}}}}, {"uuid": "d10892f4-2562-4589-abbb-e58c3bbbdbe5", "name": "9dcb1517-15a2-4fcd-949e-c7735a62b8eb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.789788128831495, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 5.104197877675544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d15b6add-9538-4b27-8b4f-eebe82806984", "name": "67e36378-dce1-4fd2-9824-8f9da766bd2c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d10892f4-2562-4589-abbb-e58c3bbbdbe5"}}}]}, {"uuid": "ad822df3-0d76-4929-945d-38f5589067a4", "name": "load_p1rlv533_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f79bc5f-375f-4ecd-b828-eb7b137d7cab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d15b6add-9538-4b27-8b4f-eebe82806984"}}}}, {"uuid": "ae02b387-1fd5-4a79-8eed-9a740d62b494", "name": "4823141d-b517-4d47-9c11-5a9d94ba773f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.789788128831495, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 5.104197877675544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "99541b60-fd2b-4302-bed5-43ba04e59d08", "name": "8099a6a3-dd55-4a38-a314-51295e3bfa2a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ae02b387-1fd5-4a79-8eed-9a740d62b494"}}}]}, {"uuid": "c2badedc-6ebd-477c-9ff0-9d83cd96671f", "name": "load_p1rlv533_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f79bc5f-375f-4ecd-b828-eb7b137d7cab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "99541b60-fd2b-4302-bed5-43ba04e59d08"}}}}, {"uuid": "6fd8c910-05ab-4e2e-96ca-a0bf62a01f30", "name": "8d91e304-d583-4a4b-862e-370c05d9fbe4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.504585200899067, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1614896338945686, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "90ff893c-5696-4cba-a481-4a0bb14f3407", "name": "ae047cdb-aeef-4a48-a4c9-b5f1e0c2c7c3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6fd8c910-05ab-4e2e-96ca-a0bf62a01f30"}}}]}, {"uuid": "43ed6dc8-dc77-4444-bf68-f73ff89a3407", "name": "load_p1rlv534_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0eb7074c-0745-4089-9329-aa3495f9b460"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "90ff893c-5696-4cba-a481-4a0bb14f3407"}}}}, {"uuid": "cedc9d19-d4d6-4694-a37c-887b76cad22f", "name": "9064d56b-453f-427f-98e9-e6bbff3cbfc1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.504585200899067, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1614896338945686, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3a43066d-745a-46de-982f-db83487f1a5f", "name": "d5034cec-1823-4361-8099-fa7676d8340e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cedc9d19-d4d6-4694-a37c-887b76cad22f"}}}]}, {"uuid": "d6d0bf46-ec50-4d26-b2d2-9fbf24a065cb", "name": "load_p1rlv534_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0eb7074c-0745-4089-9329-aa3495f9b460"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3a43066d-745a-46de-982f-db83487f1a5f"}}}}, {"uuid": "8eb73e5a-26ba-49e3-87b4-22016ac4eb9d", "name": "12013ea5-b812-4b9b-ad08-995006bf8ba9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.469077677978515, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3943727551399522, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b5b64d97-745a-4e70-b8d7-dce5eb3aadfc", "name": "ae3f01dd-2c40-41ef-bdf2-e9af34d6c3e7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8eb73e5a-26ba-49e3-87b4-22016ac4eb9d"}}}]}, {"uuid": "5a3c7273-5a95-4fd9-9e3a-4abfb773fbd2", "name": "load_p1rlv535_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9cc91945-564c-4ace-bb53-77150b107b41"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b5b64d97-745a-4e70-b8d7-dce5eb3aadfc"}}}}, {"uuid": "315291bc-784c-4b13-8505-fd4e1186ae77", "name": "9a714b62-4a2c-4c1d-97c4-7b429b3fffa9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.469077677978515, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3943727551399522, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eaa12b68-16e4-4231-8b3c-10991027b469", "name": "544f1730-6a8c-4030-83ff-11bc4f5f839f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "315291bc-784c-4b13-8505-fd4e1186ae77"}}}]}, {"uuid": "c7984dc5-3d90-44ff-9829-6ac742cd1eed", "name": "load_p1rlv535_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9cc91945-564c-4ace-bb53-77150b107b41"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eaa12b68-16e4-4231-8b3c-10991027b469"}}}}, {"uuid": "a6ace854-9e20-4e34-a8ac-01f0302fcf6d", "name": "43c90ffd-1e6d-4ea6-aada-9d1a91bf8efe_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.363394523648868, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.5065914416455906, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "065f8d03-acd9-4aef-bf32-ec679cb85d63", "name": "a3ed8f2e-1670-44f9-8eae-31627a7f6e4b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a6ace854-9e20-4e34-a8ac-01f0302fcf6d"}}}]}, {"uuid": "0255150b-1a31-4522-8e00-e52cf5303f41", "name": "load_p1rlv536_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2ea78a8-b9c5-4760-b153-51b45565069e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "065f8d03-acd9-4aef-bf32-ec679cb85d63"}}}}, {"uuid": "5c656de1-ba9d-489b-ae10-b9b2cc439b5b", "name": "7e21c187-648b-45f5-8192-47fa6cd85fdf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.363394523648868, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.5065914416455906, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9103a65d-75a8-4b3c-b9ff-c75118cc02df", "name": "daf7cc08-4973-45f6-9c31-f9245ec99d6f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5c656de1-ba9d-489b-ae10-b9b2cc439b5b"}}}]}, {"uuid": "c2ee4201-1d4a-4e30-aacf-9278043885fc", "name": "load_p1rlv536_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2ea78a8-b9c5-4760-b153-51b45565069e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9103a65d-75a8-4b3c-b9ff-c75118cc02df"}}}}, {"uuid": "0ca2ed02-9ad9-4b9d-9119-90d61a8f442c", "name": "d67ef7d5-94b0-4f8e-ab83-8624470c1e4e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.116603176693932, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3416039415731394, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e5767b74-2bf6-4ae0-acb8-f7db26c54e9d", "name": "fb42b4a2-841e-4022-a801-c14a2c0472a3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0ca2ed02-9ad9-4b9d-9119-90d61a8f442c"}}}]}, {"uuid": "72b2862e-3870-432b-ace8-81c712ed9d0d", "name": "load_p1rlv537_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9f2dfc9e-0b72-4465-b46a-d4e2a7a08f64"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e5767b74-2bf6-4ae0-acb8-f7db26c54e9d"}}}}, {"uuid": "23162cba-e334-4c24-8a3d-fe1db1c34086", "name": "9c924ee9-38fd-4520-9b2c-6cb755f2ff7e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.116603176693932, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3416039415731394, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "887a9b49-4c57-496a-900a-ca04d7b633c4", "name": "e54f1c45-bd2d-438b-8427-ecfd4fe61f5f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "23162cba-e334-4c24-8a3d-fe1db1c34086"}}}]}, {"uuid": "cc0d6925-8787-4d18-8616-fbf30f6c7a5a", "name": "load_p1rlv537_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9f2dfc9e-0b72-4465-b46a-d4e2a7a08f64"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "887a9b49-4c57-496a-900a-ca04d7b633c4"}}}}, {"uuid": "f479d563-a28f-487c-aba5-5b707ed429ad", "name": "ca60cbb9-048c-4e48-890a-7f6fbbe22e57_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6767459289154356, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5300288174067083, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "15daf489-d6f4-44b4-8486-5ef3e50832ad", "name": "0e758f65-c58a-4d6f-8f86-94670c97cafc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f479d563-a28f-487c-aba5-5b707ed429ad"}}}]}, {"uuid": "439e259e-fd7b-4f6b-87d9-7e0edc642f0a", "name": "load_p1rlv588_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75628d41-a82d-4425-8aa2-9f377c771a4c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "15daf489-d6f4-44b4-8486-5ef3e50832ad"}}}}, {"uuid": "0fbd767f-ece8-4ab5-ac8f-0e3782a2ad01", "name": "24e1c251-d056-4a30-bc82-aa0495716368_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6767459289154356, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5300288174067083, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a3aa04d-8ef0-49a2-ae2e-c077b3917d37", "name": "94f5cf50-5df4-4976-a4e9-e867721ce02b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0fbd767f-ece8-4ab5-ac8f-0e3782a2ad01"}}}]}, {"uuid": "3273b0f0-7ce3-4acf-ac66-549e19fb080b", "name": "load_p1rlv588_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75628d41-a82d-4425-8aa2-9f377c771a4c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0a3aa04d-8ef0-49a2-ae2e-c077b3917d37"}}}}, {"uuid": "5454428d-4b56-4c90-907c-d2e9f84a7cfd", "name": "c60191c3-09f3-420e-8bb1-27609dba5428_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8288850538480296, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31695217299610473, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "656c4d3a-9a01-4536-a830-009e8a1c604a", "name": "49d4c517-8c33-4849-91f9-ddd6d490ca31", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5454428d-4b56-4c90-907c-d2e9f84a7cfd"}}}]}, {"uuid": "6c13ec2c-acf6-4759-8425-ea576533c0dc", "name": "load_p1rlv589_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a1c60be-f1a1-48d6-b396-4cca6d8c4e62"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "656c4d3a-9a01-4536-a830-009e8a1c604a"}}}}, {"uuid": "ec435995-213c-4d1e-9b6b-df574871d42d", "name": "40b103c5-1c82-4aee-970a-e97519bb40a7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8288850538480296, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31695217299610473, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "faf98a77-df0a-477b-9f0f-6c363b5d2123", "name": "d7863b9b-b520-4877-b8bb-f9ef347b1395", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ec435995-213c-4d1e-9b6b-df574871d42d"}}}]}, {"uuid": "5c7d4191-8a3a-41c7-96f9-0bf89787fb72", "name": "load_p1rlv589_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a1c60be-f1a1-48d6-b396-4cca6d8c4e62"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "faf98a77-df0a-477b-9f0f-6c363b5d2123"}}}}, {"uuid": "3beaa7fe-e44e-44c0-8550-d2dae7715ac7", "name": "790e25fc-e449-4b27-ac54-1c45374122f5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.696455257947775, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.26943121901999684, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9a4ea290-c792-4ca9-8131-861a4fe68281", "name": "7302f3af-6f22-4f34-8c25-ece13254bfd8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3beaa7fe-e44e-44c0-8550-d2dae7715ac7"}}}]}, {"uuid": "7af173ca-da42-4ca5-b075-bdda3d3b89b8", "name": "load_p1rlv590_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81ce208e-7244-418a-9867-b55b95ba0716"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9a4ea290-c792-4ca9-8131-861a4fe68281"}}}}, {"uuid": "a849ebcb-fdce-4c2e-9923-7e6dd4671f26", "name": "aa41234b-e5d6-46df-bfa3-f936d97f3b39_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.696455257947775, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.26943121901999684, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "63e9d6da-3858-4395-859b-5e91c85df054", "name": "2aba41cc-ff74-4ae2-8f3c-83d6584d1cdc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a849ebcb-fdce-4c2e-9923-7e6dd4671f26"}}}]}, {"uuid": "8821a99d-8519-45d6-8371-606244795fe4", "name": "load_p1rlv590_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81ce208e-7244-418a-9867-b55b95ba0716"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "63e9d6da-3858-4395-859b-5e91c85df054"}}}}, {"uuid": "e23c6472-6af6-4c1e-932d-82123696e1c7", "name": "9f2ff2ae-cb4c-4205-874f-eb54aa1f32c9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.201469129926609, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0819349187657892, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6ed963ec-d8f3-47a6-b9ef-1624186b18da", "name": "ed5a8730-72c7-42e7-accc-d7028a2d3820", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e23c6472-6af6-4c1e-932d-82123696e1c7"}}}]}, {"uuid": "cbc47274-6a9a-4433-b62e-9b0e76aa835d", "name": "load_p1rlv657_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e58890e-e6ce-4dda-91c0-5ccfdb5c420d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6ed963ec-d8f3-47a6-b9ef-1624186b18da"}}}}, {"uuid": "65b73121-cc40-40d2-bddb-6b806f9c9c6d", "name": "eb47a207-eec2-4443-8388-f1644c875527_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.201469129926609, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0819349187657892, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d759b4b2-abec-4247-9cdb-3a0eafa5c792", "name": "d19accf4-becc-4df4-b130-93ba848b0f46", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "65b73121-cc40-40d2-bddb-6b806f9c9c6d"}}}]}, {"uuid": "abab5b2f-4b1c-487f-9c44-2e6d023e44f8", "name": "load_p1rlv657_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e58890e-e6ce-4dda-91c0-5ccfdb5c420d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d759b4b2-abec-4247-9cdb-3a0eafa5c792"}}}}, {"uuid": "0adb4448-1fc9-4ca0-aaab-5784dc663298", "name": "03cf9e18-143d-46fa-b23a-2636cc112a71_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1427818095792333, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033588044558321, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7ecc59f0-062e-4ed5-8351-d96ea59cb8f0", "name": "2961c013-da08-4474-ac53-1bd736e3b497", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0adb4448-1fc9-4ca0-aaab-5784dc663298"}}}]}, {"uuid": "997296ac-dae1-4e24-91df-20a54b89fd04", "name": "load_p1rlv660_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15751ee2-6783-472f-ad57-ec978234fec4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7ecc59f0-062e-4ed5-8351-d96ea59cb8f0"}}}}, {"uuid": "930ffc53-d75a-41a4-8954-7b674d2f4af9", "name": "107ff0d1-7f72-41fb-ae12-5f0d4767108e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1427818095792333, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033588044558321, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "67c3a1d4-fc5a-4a0c-8e6e-b8450ea2d0db", "name": "25c8bf86-cc0a-427c-9964-cf4625f8a763", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "930ffc53-d75a-41a4-8954-7b674d2f4af9"}}}]}, {"uuid": "acb5b681-5b80-45dc-b349-c71b951c0130", "name": "load_p1rlv660_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15751ee2-6783-472f-ad57-ec978234fec4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "67c3a1d4-fc5a-4a0c-8e6e-b8450ea2d0db"}}}}, {"uuid": "73e32d34-7add-44a2-ad8b-44f65d59b253", "name": "78b53566-5bcd-4798-971c-7e9eda98137f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7935386970404408, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "353c28a6-2d33-4062-9cb5-cdaa5812041f", "name": "7868a77f-5078-42de-8c51-9bfb7ac7066e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "73e32d34-7add-44a2-ad8b-44f65d59b253"}}}]}, {"uuid": "00ee95d8-2b16-4183-adf1-e90910dbd1d1", "name": "load_p1rlv672_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb25bf05-ce7f-405a-8c17-fd166748f7d3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "353c28a6-2d33-4062-9cb5-cdaa5812041f"}}}}, {"uuid": "454c48ee-7a4d-4380-8af5-b777bf2faf5a", "name": "be5dac99-946a-4df5-8952-d1147d3fdd3b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7935386970404408, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "67770ecd-bc51-43f6-a467-df322344d97f", "name": "9b7192a2-8782-4dd6-925b-2fd55240b789", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "454c48ee-7a4d-4380-8af5-b777bf2faf5a"}}}]}, {"uuid": "2539222d-42f5-4f63-97e7-8c79633002cd", "name": "load_p1rlv672_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb25bf05-ce7f-405a-8c17-fd166748f7d3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "67770ecd-bc51-43f6-a467-df322344d97f"}}}}, {"uuid": "8a2565fc-2d10-411c-8b58-83ef9b8ba177", "name": "623d7d87-a72d-40d7-b15b-85211aeb8f62_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6873327290171372, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.38872845841522474, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "943ccbbf-545d-4d49-9fd9-da21451999ea", "name": "a0ff9f0f-f8db-4490-bb2a-c6659b925e09", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a2565fc-2d10-411c-8b58-83ef9b8ba177"}}}]}, {"uuid": "c22f9cd1-7aeb-4504-8fde-e07798bc325c", "name": "load_p1rlv673_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31d3267c-7020-4660-9a0b-49cd9d94a5d0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "943ccbbf-545d-4d49-9fd9-da21451999ea"}}}}, {"uuid": "52af43a7-2e10-476d-8f79-b64cc7623bfb", "name": "afc205a7-9f2d-4fd7-b294-a779ae841c7c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6873327290171372, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.38872845841522474, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "45401b66-ff96-4eea-9815-3750c71f19fe", "name": "2210476a-d427-48ac-aade-1e24916762a3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "52af43a7-2e10-476d-8f79-b64cc7623bfb"}}}]}, {"uuid": "56dd86e6-118f-4e7b-be9e-80e878193209", "name": "load_p1rlv673_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31d3267c-7020-4660-9a0b-49cd9d94a5d0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "45401b66-ff96-4eea-9815-3750c71f19fe"}}}}, {"uuid": "f23b238e-c41b-443f-976a-5439245d3616", "name": "282b9f7a-558f-4bae-be6b-4b852c874a38_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.629144238694082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9654448182756213, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1669e9ce-f614-4955-a87e-dd5775809296", "name": "465f7b3a-9ee2-4371-a88c-221f1773518a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f23b238e-c41b-443f-976a-5439245d3616"}}}]}, {"uuid": "bbeff04d-d4e6-49a0-8728-228f48fafd80", "name": "load_p1rlv674_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "449992d6-a91b-40ea-9792-5166a5f2c849"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1669e9ce-f614-4955-a87e-dd5775809296"}}}}, {"uuid": "697cc389-c07a-4dc3-86ea-c2559e23b687", "name": "413ebfd2-b99c-47df-90c6-dc5d1d8ea19e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.629144238694082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9654448182756213, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d1530a61-86d4-4018-bd0f-dcb9c860acb7", "name": "f8554fd1-2ba0-4cc7-b987-61922233324b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "697cc389-c07a-4dc3-86ea-c2559e23b687"}}}]}, {"uuid": "2a50a4d9-31db-4326-8b24-51ddf0b96e18", "name": "load_p1rlv674_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "449992d6-a91b-40ea-9792-5166a5f2c849"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d1530a61-86d4-4018-bd0f-dcb9c860acb7"}}}}, {"uuid": "e4d98caf-81e1-4441-b631-5c089e5d1282", "name": "a82f2924-5745-42c2-b066-45d94daed215_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2527429497469504, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5005012096685874, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1df1739a-2fb0-45e1-9b23-8363bbc5125c", "name": "df7aed15-398f-410c-829d-3b9905adf57a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e4d98caf-81e1-4441-b631-5c089e5d1282"}}}]}, {"uuid": "ede5311a-13dd-4156-8805-07596031707f", "name": "load_p1rlv716_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "93069f0f-fce7-47cd-b7b3-77e861f59573"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1df1739a-2fb0-45e1-9b23-8363bbc5125c"}}}}, {"uuid": "58392726-d0ac-4fe6-9dba-23581fc55985", "name": "f9fbe0ae-67ea-4039-9754-89cd2da347b0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2527429497469504, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5005012096685874, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2b89be86-388c-400b-b82c-a5e26babb039", "name": "acacb8f3-dd51-4dc1-9b99-7c14d0cd1ba5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58392726-d0ac-4fe6-9dba-23581fc55985"}}}]}, {"uuid": "1f87880a-e02f-4c82-a483-7f3d08ad74f0", "name": "load_p1rlv716_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "93069f0f-fce7-47cd-b7b3-77e861f59573"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2b89be86-388c-400b-b82c-a5e26babb039"}}}}, {"uuid": "bf496c73-e70e-423a-96b1-fec14de1cae3", "name": "f310019d-dc68-401e-a608-8f9873831b88_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.916354724025409, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9016755043678467, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ee026057-b475-41b4-9779-c9e655f595e4", "name": "55e3eda6-0059-4f6f-99e1-fd657134df3d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bf496c73-e70e-423a-96b1-fec14de1cae3"}}}]}, {"uuid": "bfa2a69f-a518-48d9-b301-9ecedffbc7df", "name": "load_p1rlv717_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd8fd159-f747-4ee4-a426-787f4eef4b42"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ee026057-b475-41b4-9779-c9e655f595e4"}}}}, {"uuid": "28596690-1a72-4eb3-88be-d63b33a6aa7b", "name": "e4e5404d-c770-4339-b715-c92a48adccff_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.916354724025409, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9016755043678467, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "38f4e1b1-3d21-4665-9b25-7d4717c4cf7d", "name": "588b544f-3513-4e91-b239-0cb86d9d9ab0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "28596690-1a72-4eb3-88be-d63b33a6aa7b"}}}]}, {"uuid": "afeb6c0e-ac4d-455f-aaf8-562288cbf02c", "name": "load_p1rlv717_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd8fd159-f747-4ee4-a426-787f4eef4b42"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "38f4e1b1-3d21-4665-9b25-7d4717c4cf7d"}}}}, {"uuid": "68031fd5-2533-4e56-9d65-f86eb933be4f", "name": "6db53d39-c949-4671-af40-bb2a932b8663_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.786120494572624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2344198860247402, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f056302a-9feb-4ed2-99b8-d266c61b39a6", "name": "af07bc93-3dcf-4220-8b1c-ecada1320a11", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "68031fd5-2533-4e56-9d65-f86eb933be4f"}}}]}, {"uuid": "977afcb1-5009-4ac4-b614-e3ca9da3a132", "name": "load_p1rlv718_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4a1453b-98a3-4c2d-8ac2-c8b2ab1bfa4f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f056302a-9feb-4ed2-99b8-d266c61b39a6"}}}}, {"uuid": "3585aea3-3794-4904-9bea-6f6577ba20d1", "name": "4ebb5e28-2f63-4b4f-b4b3-1e3f25027fba_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.786120494572624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2344198860247402, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f395d072-a839-4ac6-b22a-ba64f15a695f", "name": "dc5bb47e-ac2d-4fd7-9799-2d2244310396", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3585aea3-3794-4904-9bea-6f6577ba20d1"}}}]}, {"uuid": "acd07cca-61e9-4d04-a311-705836ab8e65", "name": "load_p1rlv718_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4a1453b-98a3-4c2d-8ac2-c8b2ab1bfa4f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f395d072-a839-4ac6-b22a-ba64f15a695f"}}}}, {"uuid": "b18f4b09-ed17-44bc-91ed-0c1ab5fd29f0", "name": "352ee402-7303-457c-8250-6c8740280031_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.872791085416893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.761492956317497, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6c62ae6d-d04e-4992-ae3f-25bd74f7a2f5", "name": "5b7571da-3ce0-486f-b952-4b3fea385372", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b18f4b09-ed17-44bc-91ed-0c1ab5fd29f0"}}}]}, {"uuid": "79c3a6fa-cd50-451c-96b7-2b35828c1130", "name": "load_p1rlv719_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3153167-8b4c-40e4-abb7-3bdef86950c3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6c62ae6d-d04e-4992-ae3f-25bd74f7a2f5"}}}}, {"uuid": "446dea59-a20d-4230-9868-466622a8596f", "name": "49bc3b2c-a430-418b-ae9b-1dbfe1acf7da_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.872791085416893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.761492956317497, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ed8a7b8a-0b5f-4835-96b4-03b2e8233240", "name": "022113f8-efad-4ccb-b324-6be956eedc22", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "446dea59-a20d-4230-9868-466622a8596f"}}}]}, {"uuid": "5d798181-b869-42ea-ad5c-4ffb250a43c6", "name": "load_p1rlv719_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3153167-8b4c-40e4-abb7-3bdef86950c3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ed8a7b8a-0b5f-4835-96b4-03b2e8233240"}}}}, {"uuid": "78dca5a5-2c84-4ac1-b8e3-d85046b179ac", "name": "4885aac2-d383-42d3-b012-fa12ac7c001b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.000000644073754, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1655557120603839, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b7861d22-0711-4175-8380-6949e323537c", "name": "c240c5ca-e0d0-49f6-89b3-f39f936d3cf4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "78dca5a5-2c84-4ac1-b8e3-d85046b179ac"}}}]}, {"uuid": "ae80bdbe-4444-4eac-97fb-51bcb6cc2d84", "name": "load_p1rlv720_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdbc11b7-5abf-4ff8-8d26-53faf4b1f3f5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b7861d22-0711-4175-8380-6949e323537c"}}}}, {"uuid": "1d863231-f17e-4b90-b3c8-a71a7ff0d81e", "name": "5428a001-da2b-48f0-8ac3-13506a749c4a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.000000644073754, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1655557120603839, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f0bdde55-7be0-4905-8777-cd2aff83f410", "name": "4154317d-cfc9-4a54-9941-94974a1c7930", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1d863231-f17e-4b90-b3c8-a71a7ff0d81e"}}}]}, {"uuid": "0d1c5f25-f550-471e-a519-97e3204a3ce9", "name": "load_p1rlv720_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdbc11b7-5abf-4ff8-8d26-53faf4b1f3f5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f0bdde55-7be0-4905-8777-cd2aff83f410"}}}}, {"uuid": "eb054f98-f757-4381-a754-386a4f692c7e", "name": "cd70e24d-36fb-4c38-9091-a607a7510221_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5041010955030301, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21577690333785765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1769bd12-ea2f-4e78-b9b4-d466df50ed95", "name": "e3a31a47-8ce6-4377-b101-b708d47ee0c4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eb054f98-f757-4381-a754-386a4f692c7e"}}}]}, {"uuid": "90a60c4d-b19b-45e9-88a5-f37644403db8", "name": "load_p1rlv721_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf12b67c-4df5-4dcb-a2e2-6ae2d0f82e65"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1769bd12-ea2f-4e78-b9b4-d466df50ed95"}}}}, {"uuid": "e6ccadcb-551c-4fce-9af8-b2c1ce35e751", "name": "adb54d5f-cca1-41b2-b7f0-30b4ca644bd3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5041010955030301, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21577690333785765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6d569f9f-5b10-4009-a8e9-d27ed169cb1c", "name": "f2aed3a1-839d-4ccd-b083-5939d16814d8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e6ccadcb-551c-4fce-9af8-b2c1ce35e751"}}}]}, {"uuid": "36af70ed-991f-4f4d-a0c6-02bfeb5237a9", "name": "load_p1rlv721_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf12b67c-4df5-4dcb-a2e2-6ae2d0f82e65"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6d569f9f-5b10-4009-a8e9-d27ed169cb1c"}}}}, {"uuid": "5f3616e6-0f56-49dc-962f-5a9371bb503e", "name": "be256f82-a4ca-4c22-aa1c-f53f933a408d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6733980323267108, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22626974414284334, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "900a87a8-5526-4eb4-b5a0-979080a61198", "name": "f62b6131-8890-4ca4-ac96-d20f59ace51b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5f3616e6-0f56-49dc-962f-5a9371bb503e"}}}]}, {"uuid": "ce2e7d49-8d13-4420-86ed-e25fa9f409cb", "name": "load_p1rlv722_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b7c6c65-e18c-4e79-b419-8894deb0d345"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "900a87a8-5526-4eb4-b5a0-979080a61198"}}}}, {"uuid": "91a1f911-9c6e-4f9d-b57a-24870fb2799a", "name": "3ced0a9a-c4e6-4a5a-ac86-9fed36368435_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6733980323267108, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22626974414284334, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8c040eae-447e-41cd-98e3-95b28f9c3636", "name": "9c50eea9-4cd9-45ca-9f4b-53d8c330a52f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "91a1f911-9c6e-4f9d-b57a-24870fb2799a"}}}]}, {"uuid": "af969afc-6753-4848-a059-1b3dd13285ac", "name": "load_p1rlv722_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b7c6c65-e18c-4e79-b419-8894deb0d345"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8c040eae-447e-41cd-98e3-95b28f9c3636"}}}}, {"uuid": "d0e3b089-c79e-4876-95b1-fb7d504380c2", "name": "4948e182-fabc-4164-82d3-ddf56e545b76_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2596055778412756, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4460523908595607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "120e19ed-92c5-4d00-b8b3-c9761ba75852", "name": "a7cc84eb-7b9c-4b97-a044-1f3f2bfadd43", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d0e3b089-c79e-4876-95b1-fb7d504380c2"}}}]}, {"uuid": "cc7beee9-ae31-4720-b679-66236113c044", "name": "load_p1rlv723_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7551be44-a4ca-4edb-b823-6495d163201e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "120e19ed-92c5-4d00-b8b3-c9761ba75852"}}}}, {"uuid": "f56ecadc-4862-4e7b-8afa-2d10acd0e581", "name": "0fde8a58-763b-43d1-93d1-4de9b34f2660_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2596055778412756, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4460523908595607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e82878f4-7239-4c3a-8d86-512ea4be2428", "name": "0b72b0d5-3710-48c1-8165-3fc647a05336", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f56ecadc-4862-4e7b-8afa-2d10acd0e581"}}}]}, {"uuid": "c03cf62f-3808-464a-b0b0-216bc94398b6", "name": "load_p1rlv723_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7551be44-a4ca-4edb-b823-6495d163201e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e82878f4-7239-4c3a-8d86-512ea4be2428"}}}}, {"uuid": "206ccb98-6132-4ee4-9c61-598990f1ef36", "name": "414d01c4-24ab-4828-bed6-9792187e017e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.794005533851084, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6855099409421886, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b839b6ba-2d40-44a3-8a83-1b9c240ff553", "name": "fe0822bd-009c-49aa-8c17-d6519e77523a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "206ccb98-6132-4ee4-9c61-598990f1ef36"}}}]}, {"uuid": "cda0e6a3-6816-4724-9d32-66cf642a638b", "name": "load_p1rlv724_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3658479-7369-4bd9-be54-e7768c93a808"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b839b6ba-2d40-44a3-8a83-1b9c240ff553"}}}}, {"uuid": "ab4a0044-8726-4027-8728-cab4f9c28832", "name": "d9befc77-f563-4e77-8348-4a35a3f6204c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.794005533851084, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6855099409421886, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5013d830-da3a-4cc4-bae0-872873f72f9d", "name": "3179e716-63ce-4f4e-84f7-a115095ff69b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ab4a0044-8726-4027-8728-cab4f9c28832"}}}]}, {"uuid": "32b32edf-0faa-4b81-8ce6-dc1f54bb4230", "name": "load_p1rlv724_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3658479-7369-4bd9-be54-e7768c93a808"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5013d830-da3a-4cc4-bae0-872873f72f9d"}}}}, {"uuid": "b17267ee-47c5-411a-a31b-ebe7f1237538", "name": "8ab8e5d0-1269-44e5-8fbe-90c56e6bea92_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7997673490012955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.772957044307952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "63ea1069-71be-457d-9839-65489224aa34", "name": "55100585-da78-4e58-bb3e-7b5689090e75", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b17267ee-47c5-411a-a31b-ebe7f1237538"}}}]}, {"uuid": "18c72770-ada5-451b-a875-7af3a4e7e5e4", "name": "load_p1rlv725_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2bcbabc-a7fc-4230-8ec1-b6050af9cf58"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "63ea1069-71be-457d-9839-65489224aa34"}}}}, {"uuid": "202490d4-2e13-4030-9563-cd2d19bd3793", "name": "5d799024-2182-434b-a3aa-eb41f7d2d023_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7997673490012955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.772957044307952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2eba0569-eddf-44d2-b873-54968c0ff842", "name": "fc05ed22-e71c-46e6-94df-0433df5a2457", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "202490d4-2e13-4030-9563-cd2d19bd3793"}}}]}, {"uuid": "f7902d74-d4ed-43ba-af65-9db169a096e8", "name": "load_p1rlv725_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2bcbabc-a7fc-4230-8ec1-b6050af9cf58"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2eba0569-eddf-44d2-b873-54968c0ff842"}}}}, {"uuid": "35be8c28-4603-4c6d-b4bd-a972a67044dc", "name": "4020d951-95a0-453f-b69f-2cd0350929b1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.762685564172624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.7175951697927787, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4fefaa1d-8570-4fdd-908d-f3877c473c07", "name": "394b95f6-b12a-4cc1-98de-303c5877fe0a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "35be8c28-4603-4c6d-b4bd-a972a67044dc"}}}]}, {"uuid": "0b358c72-6f60-48ae-8c2c-3c786b5a52fc", "name": "load_p1rlv726_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fdcbc55-681f-4fe5-8142-4945b25f6fef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4fefaa1d-8570-4fdd-908d-f3877c473c07"}}}}, {"uuid": "654ab3ed-1580-4c7a-a3db-4cd47906bb85", "name": "aacb3ee5-917c-4517-b756-44a73b1213d8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.762685564172624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.7175951697927787, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2e4cb72a-c229-4b25-b5c8-012e536eb05a", "name": "d39ceafe-765a-4fa3-bbb0-01872c9a5dc1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "654ab3ed-1580-4c7a-a3db-4cd47906bb85"}}}]}, {"uuid": "bd703703-bee0-41ea-9c5a-2bb2e1a77c77", "name": "load_p1rlv726_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fdcbc55-681f-4fe5-8142-4945b25f6fef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2e4cb72a-c229-4b25-b5c8-012e536eb05a"}}}}, {"uuid": "c9b17eaa-a404-4df1-aa43-fad0d049acac", "name": "914c059f-404a-49d2-be3f-3a4bbfa166d8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.981510789736824, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31377757670385525, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2e07e5a2-10ac-4133-a440-a0264b5555a1", "name": "b7887293-b0cd-4eb6-9448-45496ea31cbc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9b17eaa-a404-4df1-aa43-fad0d049acac"}}}]}, {"uuid": "7a93df03-8bc9-4742-b9f2-132964907df8", "name": "load_p1rlv749_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80983704-a98f-46dc-a09f-700bd7df1a29"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2e07e5a2-10ac-4133-a440-a0264b5555a1"}}}}, {"uuid": "1ccee909-af72-488c-ac95-cf3da56f22d5", "name": "fa888314-932e-4416-ab8a-3efe94677372_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.981510789736824, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31377757670385525, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4465aaeb-7114-4a39-88d9-ae13308d7239", "name": "d2c1e38f-6d88-4622-a3c7-9e43fa043ade", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1ccee909-af72-488c-ac95-cf3da56f22d5"}}}]}, {"uuid": "1748effe-25e9-4eb7-bf52-0121f8ec8725", "name": "load_p1rlv749_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80983704-a98f-46dc-a09f-700bd7df1a29"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4465aaeb-7114-4a39-88d9-ae13308d7239"}}}}, {"uuid": "97595f54-fa68-4bc7-a5d8-08e42f71deb9", "name": "5a922f5f-0a3a-4a86-b0b2-2bd83a97c70e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3612560165719545, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7198526424662817, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2284f4af-57f8-481e-845b-620d59dd587c", "name": "25785f91-6b3b-4678-ab4f-a5c1c5582b2e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "97595f54-fa68-4bc7-a5d8-08e42f71deb9"}}}]}, {"uuid": "4068cc20-6387-452c-b2d9-f20698ada793", "name": "load_p1rlv756_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3c3b0fb-5a5d-439e-a350-b97ba0df41a0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2284f4af-57f8-481e-845b-620d59dd587c"}}}}, {"uuid": "6dfd623a-6445-4a09-814a-c64d2133b497", "name": "78e36fd2-0a28-4227-bc4a-c4a8a7015c3b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3612560165719545, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7198526424662817, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2f73c189-c676-4215-b467-dc29671c2291", "name": "757afc2b-5fc3-49df-86c7-eb3e0da98a49", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6dfd623a-6445-4a09-814a-c64d2133b497"}}}]}, {"uuid": "6ad9daeb-12ab-4094-8f0a-f1d464b428a0", "name": "load_p1rlv756_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3c3b0fb-5a5d-439e-a350-b97ba0df41a0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2f73c189-c676-4215-b467-dc29671c2291"}}}}, {"uuid": "095ab4d6-8a69-462d-a850-f0b13520dbc4", "name": "14aa8b69-3b5d-4b12-9027-e1f27c344633_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.910200682298975, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5555412020426419, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a53fa2df-1c44-4551-970d-eaf3bf4ff3aa", "name": "671c0fa0-40f7-43af-8879-e9ed849c7b38", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "095ab4d6-8a69-462d-a850-f0b13520dbc4"}}}]}, {"uuid": "49bfdc0b-b1f1-4793-a1ee-c23ebccfb7ca", "name": "load_p1rlv764_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e368704b-6c4b-4afb-a577-4b0d7a96dd65"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a53fa2df-1c44-4551-970d-eaf3bf4ff3aa"}}}}, {"uuid": "98e825f3-67b7-4c37-94e4-ba4cd44d1c77", "name": "75b95e6b-993e-49d1-beaf-05ad1485d9dc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.910200682298975, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5555412020426419, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ac754445-1442-4550-905e-8e707d74471b", "name": "cba8842f-933e-489e-addf-3b06dcb6b8f1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "98e825f3-67b7-4c37-94e4-ba4cd44d1c77"}}}]}, {"uuid": "76bba039-59f2-4f78-8883-71aa2de6a56f", "name": "load_p1rlv764_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e368704b-6c4b-4afb-a577-4b0d7a96dd65"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ac754445-1442-4550-905e-8e707d74471b"}}}}, {"uuid": "da122198-fdf4-4f17-91f4-a07f00b0635a", "name": "d2b79295-98d1-4ac5-9fd4-50f63968a697_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4856814769108864, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8267323554826451, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "981253cf-9ec0-46de-96c7-894d0ea481f3", "name": "14cc4b68-7bdb-4ee6-85d8-136e91f1acbc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "da122198-fdf4-4f17-91f4-a07f00b0635a"}}}]}, {"uuid": "bd077c4a-347f-469a-9666-a1ffd44e74e9", "name": "load_p1rlv766_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07381934-8e9b-4447-a330-e8af484331f1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "981253cf-9ec0-46de-96c7-894d0ea481f3"}}}}, {"uuid": "44b0c0d9-18c0-456c-badf-3f0150e3ff71", "name": "376debc5-4871-42ec-a45b-c7ca0f7641fb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4856814769108864, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8267323554826451, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "24537064-7722-4085-ae94-ad0a58eafd75", "name": "a38cdba4-704d-4fa8-ba52-cd2636dd6f24", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "44b0c0d9-18c0-456c-badf-3f0150e3ff71"}}}]}, {"uuid": "cb470b47-d7b1-400f-8605-511c302fd177", "name": "load_p1rlv766_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07381934-8e9b-4447-a330-e8af484331f1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "24537064-7722-4085-ae94-ad0a58eafd75"}}}}, {"uuid": "2d0835b7-8d42-4dbe-bab2-b7cf2bd0a3ce", "name": "c9a27d67-ee66-48b5-9c74-241a63a61769_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7083181921938193, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5666922324635131, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b009a683-06f5-412d-b28a-2d70d330b918", "name": "12fdd19f-c9c9-4712-87a7-0eb4cfeeea43", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2d0835b7-8d42-4dbe-bab2-b7cf2bd0a3ce"}}}]}, {"uuid": "af3c78f3-2c17-4189-920c-66419131c6f5", "name": "load_p1rlv775_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d00977fb-8d2a-44ca-aa9e-034894d6e280"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b009a683-06f5-412d-b28a-2d70d330b918"}}}}, {"uuid": "bfa66587-5224-4964-bf22-adc45a8102b5", "name": "efb56f1f-ea09-462e-bf7a-c0d3aef7d273_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7083181921938193, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5666922324635131, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "af7f6606-be0b-4ffb-9ad5-14dc2b7b129c", "name": "f4304dad-8b4c-4aec-b5ba-69374fbc18a6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bfa66587-5224-4964-bf22-adc45a8102b5"}}}]}, {"uuid": "e98e2389-7cf7-4dd2-92bd-be1be91c4a06", "name": "load_p1rlv775_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d00977fb-8d2a-44ca-aa9e-034894d6e280"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "af7f6606-be0b-4ffb-9ad5-14dc2b7b129c"}}}}, {"uuid": "c647da92-87b1-48a3-92c2-188de6a9533d", "name": "7da23661-24f7-4c1d-84c2-5e0d59552fad_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.779437116944347, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0510023138100544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bba4366b-4b54-4a75-a4b3-4ba63f4de749", "name": "91699525-1af6-4e00-b7c7-5cd4d14db0dd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c647da92-87b1-48a3-92c2-188de6a9533d"}}}]}, {"uuid": "bf3f6187-ae8e-4b4a-bac1-260d3b7c7bba", "name": "load_p1rlv776_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c5b1f75-47c0-45c3-9ef3-f97a445b242e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bba4366b-4b54-4a75-a4b3-4ba63f4de749"}}}}, {"uuid": "ed7c1fbd-90bd-42f8-bdda-65b54bacce7c", "name": "0b724cdf-7e23-40d8-85ef-44b2fef77f36_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.779437116944347, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0510023138100544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "68bafba1-5b2b-40db-b17e-442cca8e5d82", "name": "c9bae9e4-9c6d-4106-81be-52b260b3b36e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ed7c1fbd-90bd-42f8-bdda-65b54bacce7c"}}}]}, {"uuid": "8f8d4df1-5a48-4c4c-b74b-f1c95de4cc03", "name": "load_p1rlv776_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c5b1f75-47c0-45c3-9ef3-f97a445b242e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "68bafba1-5b2b-40db-b17e-442cca8e5d82"}}}}, {"uuid": "0df6d500-fb5a-4499-a196-31a12b23a034", "name": "be8c7f3b-9a68-4c98-9632-9cdbf579b8cb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3483029031483318, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6505451661884267, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b0a276b7-d3fc-4c8f-9da5-216c398babf3", "name": "334fc552-b885-4faa-bb7e-c1332260f2e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0df6d500-fb5a-4499-a196-31a12b23a034"}}}]}, {"uuid": "da976a87-52f4-48fc-b48d-c87ee7f367c3", "name": "load_p1rlv777_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fb1fca8-7985-4356-a8de-7433fef7a454"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b0a276b7-d3fc-4c8f-9da5-216c398babf3"}}}}, {"uuid": "f184f240-c154-4d08-99f3-6d35887d55fc", "name": "a20f9e8b-6285-4a23-bf3c-811d440ca941_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3483029031483318, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6505451661884267, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8fd141ec-66ef-48ae-b92c-051f229c57bd", "name": "88f79e12-1637-4b3c-84a6-497f9c34b51c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f184f240-c154-4d08-99f3-6d35887d55fc"}}}]}, {"uuid": "88825692-476f-466b-852c-5593f1a76bd5", "name": "load_p1rlv777_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fb1fca8-7985-4356-a8de-7433fef7a454"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8fd141ec-66ef-48ae-b92c-051f229c57bd"}}}}, {"uuid": "e3d3a257-3499-4ef3-a6fb-094615787127", "name": "58a200ee-cf6d-4ebd-8eee-13d37cba4efe_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.993849790823018, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8230403105677124, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dbc24d2f-ac5a-4014-9727-f3022d456fe8", "name": "4d093c92-29a0-4276-b2aa-0fc8f4ea3b6d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e3d3a257-3499-4ef3-a6fb-094615787127"}}}]}, {"uuid": "cf15fdf4-d3ca-4b4f-8331-3cfee831711f", "name": "load_p1rlv778_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80d58665-ee8a-4f4e-a906-dc15aa3d8c6f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dbc24d2f-ac5a-4014-9727-f3022d456fe8"}}}}, {"uuid": "ad44b362-b8d0-43f7-88fa-5e95294fc979", "name": "83ad46c7-97e5-41bc-a258-e129c9919c7d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.993849790823018, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8230403105677124, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "af72f8ad-1709-4aa0-bd4f-a57fe996c2b8", "name": "a4c6f312-dfb4-4684-90b7-89d96afcd6e1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ad44b362-b8d0-43f7-88fa-5e95294fc979"}}}]}, {"uuid": "c1643d04-ee94-4c42-a3fa-5a9649da51c2", "name": "load_p1rlv778_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80d58665-ee8a-4f4e-a906-dc15aa3d8c6f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "af72f8ad-1709-4aa0-bd4f-a57fe996c2b8"}}}}, {"uuid": "8fda77fb-2ca6-4aae-833e-2dc48e283d3a", "name": "8f978ad7-6b29-4136-bb49-a260293e3694_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9928270585646484, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0482885249865175, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "be510307-835d-455c-a22a-907e1c4aaf34", "name": "a4e10a40-6b35-4702-b2ef-dff0376c1927", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8fda77fb-2ca6-4aae-833e-2dc48e283d3a"}}}]}, {"uuid": "bd460ab7-6f33-4ad8-bab9-c7975ca760fe", "name": "load_p1rlv779_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fbc761bf-480c-465c-9479-279832c50bc2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "be510307-835d-455c-a22a-907e1c4aaf34"}}}}, {"uuid": "757268af-82cf-4c04-8286-0ce4dfa4b093", "name": "3ee4a450-9481-4eb5-b237-5c5a878e489a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9928270585646484, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0482885249865175, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d89ab889-d4db-4be6-9a90-26f73ba46828", "name": "b35d9fbe-013c-4a1c-83b9-4ab26d855305", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "757268af-82cf-4c04-8286-0ce4dfa4b093"}}}]}, {"uuid": "95c38f40-9c71-4894-8b76-b5299a47976e", "name": "load_p1rlv779_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fbc761bf-480c-465c-9479-279832c50bc2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d89ab889-d4db-4be6-9a90-26f73ba46828"}}}}, {"uuid": "de388c37-805e-46eb-be1f-9964021fb441", "name": "6eb3ddcf-b9b7-46c4-b045-4a3c23614f63_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1813646779377422, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20173832232537287, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7747797d-7399-4cfd-94fb-22f3f4208b34", "name": "cd15d90f-9046-4e94-80cc-c53c23cbcc2d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "de388c37-805e-46eb-be1f-9964021fb441"}}}]}, {"uuid": "e1ef1997-11c2-4bde-9614-10e1366bbfa7", "name": "load_p1rlv780_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20dcf67f-f04f-498a-830d-557ba7b4d867"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7747797d-7399-4cfd-94fb-22f3f4208b34"}}}}, {"uuid": "1d52a042-3b51-466c-b0b9-9793f90674f1", "name": "c6cc7966-7cb6-477f-b0aa-90853888976c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1813646779377422, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20173832232537287, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fb5b0f15-a6a3-4798-9359-04c664a0b337", "name": "de37e0df-b3dc-4372-8ca5-780e264ad2dc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1d52a042-3b51-466c-b0b9-9793f90674f1"}}}]}, {"uuid": "eaefd462-04ca-4b42-9951-de5390cfad14", "name": "load_p1rlv780_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20dcf67f-f04f-498a-830d-557ba7b4d867"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fb5b0f15-a6a3-4798-9359-04c664a0b337"}}}}, {"uuid": "df814907-32b4-490b-85d9-6989f1b2c207", "name": "07d5c973-7b09-4ca3-a5f4-762245e9177f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.774034588817963, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.005441618856208, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6ddcad46-046e-4970-bf6c-38a406e4c1a4", "name": "92d1d692-2e0d-4fc2-88ab-4c4eb635fa55", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "df814907-32b4-490b-85d9-6989f1b2c207"}}}]}, {"uuid": "1de06a56-a8a4-480a-a591-c39f83bf866b", "name": "load_p1rlv781_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98c5ba15-a339-478a-a79f-9298fab16a54"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6ddcad46-046e-4970-bf6c-38a406e4c1a4"}}}}, {"uuid": "ae008260-0220-4b43-bb09-b7a4db443cd6", "name": "9e31d366-716f-40d7-b4b5-357d54d0210a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.774034588817963, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.005441618856208, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f9734d7e-7513-4ce5-a13d-dbc4a0bbddb0", "name": "f503e21e-f463-4a19-8165-e9b74dfdb2bf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ae008260-0220-4b43-bb09-b7a4db443cd6"}}}]}, {"uuid": "2788224b-ffa0-4a6d-a6cb-1f419fca2c75", "name": "load_p1rlv781_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98c5ba15-a339-478a-a79f-9298fab16a54"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f9734d7e-7513-4ce5-a13d-dbc4a0bbddb0"}}}}, {"uuid": "d0474588-6987-431b-b039-72a024c5dae3", "name": "ab458b61-6fdc-437e-81f1-1481b840cc6c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7457942211533133, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8784341351558463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8e6e17c4-cccb-448b-bc16-ddf2158f70eb", "name": "8d70e38a-f57a-492f-9eba-5eb3f9019373", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d0474588-6987-431b-b039-72a024c5dae3"}}}]}, {"uuid": "bdf2cf7b-27a6-44ac-bff7-46e9c4ca9478", "name": "load_p1rlv782_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78a4f54a-017a-41b0-85c8-b3e408c21c08"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8e6e17c4-cccb-448b-bc16-ddf2158f70eb"}}}}, {"uuid": "6c14eafc-a7e2-46ce-9633-4b0777173e5b", "name": "1a084ecc-2ae8-4b1f-89b3-57a1d6d523cb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7457942211533133, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8784341351558463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "99378bc7-2911-4588-b03d-343b24aff733", "name": "b06b5fa9-00fe-479c-9711-aa527b5edbb0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c14eafc-a7e2-46ce-9633-4b0777173e5b"}}}]}, {"uuid": "e354d758-9648-4666-9d70-b77f5f1f4737", "name": "load_p1rlv782_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78a4f54a-017a-41b0-85c8-b3e408c21c08"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "99378bc7-2911-4588-b03d-343b24aff733"}}}}, {"uuid": "b24be7a9-3b59-4dc6-9298-d2905610d3aa", "name": "67db29c6-ad14-4b02-ad74-5ad57266c59e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0085854932437286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7150296414254909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8b88af4f-60ed-40e2-b8bf-1abff861db1e", "name": "12db7d6d-fa2f-4fca-bb8b-337ae132b8d9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b24be7a9-3b59-4dc6-9298-d2905610d3aa"}}}]}, {"uuid": "aade8390-df77-43bb-aaa2-244c12fee2fa", "name": "load_p1rlv783_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d1a96d5-f971-4116-9642-769ef5b97e7c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8b88af4f-60ed-40e2-b8bf-1abff861db1e"}}}}, {"uuid": "d5a5cd6a-c6a5-4fc5-8189-3a3b37c9b27a", "name": "ca63e231-3b8d-41bf-ac0b-0063b1db375a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0085854932437286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7150296414254909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ed040046-fa14-42be-9b37-7f7367b7dd4c", "name": "03707f96-fecf-4a1a-90ac-9a69dad2f714", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d5a5cd6a-c6a5-4fc5-8189-3a3b37c9b27a"}}}]}, {"uuid": "d52c6675-0c5d-4f90-bbac-83a9d5e1fb0a", "name": "load_p1rlv783_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d1a96d5-f971-4116-9642-769ef5b97e7c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ed040046-fa14-42be-9b37-7f7367b7dd4c"}}}}, {"uuid": "619dcfdf-f040-45a9-85f7-1e3ef0ec179a", "name": "7eb8803a-c167-4382-a54b-b2af56d8c932_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.965154260277072, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307595255595673, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50a79a8f-7190-4a2d-9d6d-5523568e51f8", "name": "c2d95147-22cb-4130-980a-eab5c2c596d6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "619dcfdf-f040-45a9-85f7-1e3ef0ec179a"}}}]}, {"uuid": "80dfbff6-7bba-43d8-9d0e-4164c32441c6", "name": "load_p1rlv784_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2823b5b9-bcc3-4b30-9874-89dc33ec80d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50a79a8f-7190-4a2d-9d6d-5523568e51f8"}}}}, {"uuid": "deb8610a-ede2-4a10-9146-967487bff884", "name": "294b3492-4155-4b3e-9a69-ac3490d2a85d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.965154260277072, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307595255595673, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1aef9c37-bb70-4ff6-ba21-a0d54c639258", "name": "aef5eabe-1271-4dde-9863-73bfb164f73a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "deb8610a-ede2-4a10-9146-967487bff884"}}}]}, {"uuid": "913c5b60-19da-4ec3-b487-ec0578ce1904", "name": "load_p1rlv784_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2823b5b9-bcc3-4b30-9874-89dc33ec80d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1aef9c37-bb70-4ff6-ba21-a0d54c639258"}}}}, {"uuid": "c9e7b15c-61f7-4b86-90e4-bfc2aad74f55", "name": "7713e8c5-850d-43cb-a2c3-91f3834f43d7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.948680292874151, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.769988963438003, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "45345969-43ff-4427-b01b-d383cffda331", "name": "1790b739-e6c0-4648-b2ae-649d4abe5778", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9e7b15c-61f7-4b86-90e4-bfc2aad74f55"}}}]}, {"uuid": "3ac66ec1-6fb6-4c36-a2c3-e32d08f7d9ac", "name": "load_p1rlv785_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa98d6c6-7086-4033-a9af-c0a33e802942"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "45345969-43ff-4427-b01b-d383cffda331"}}}}, {"uuid": "fb9f3072-5ef5-48d6-9d07-2d2658810068", "name": "bd9c4191-59de-45a1-814b-d90568788fe8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.948680292874151, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.769988963438003, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "593c1512-b383-4ac8-98a4-827a2fcb93a6", "name": "177fe3d7-2b35-484b-875f-e7d560930137", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fb9f3072-5ef5-48d6-9d07-2d2658810068"}}}]}, {"uuid": "e1ddc0aa-3e8d-4766-a484-644f692e29e1", "name": "load_p1rlv785_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa98d6c6-7086-4033-a9af-c0a33e802942"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "593c1512-b383-4ac8-98a4-827a2fcb93a6"}}}}, {"uuid": "bc760cd2-a200-4bfd-9186-1f7acd7a1a81", "name": "456087ae-8687-410b-a07b-5303e9da9193_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0491915565570302, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1506537762556939, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5b15a43f-f62b-4614-9c68-35ba1f43fb5c", "name": "186ec91e-c15b-4f56-98ff-82750ff6d8db", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bc760cd2-a200-4bfd-9186-1f7acd7a1a81"}}}]}, {"uuid": "d859e8e9-e36f-418b-a618-7d5a905ca868", "name": "load_p1rlv786_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180adab2-e49b-42e9-9aeb-42be0a7686c5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5b15a43f-f62b-4614-9c68-35ba1f43fb5c"}}}}, {"uuid": "3a1c632a-ce42-42cb-ae94-48b8907ff209", "name": "bb5dcfcf-f220-438e-a891-8f1e45366dbb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0491915565570302, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1506537762556939, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aae090e5-66ce-4226-a0dc-088b17d1c483", "name": "c65f9925-017a-4930-8312-dade9bf74b58", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3a1c632a-ce42-42cb-ae94-48b8907ff209"}}}]}, {"uuid": "8dd7c44e-a653-498e-be77-b6b12110969f", "name": "load_p1rlv786_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180adab2-e49b-42e9-9aeb-42be0a7686c5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aae090e5-66ce-4226-a0dc-088b17d1c483"}}}}, {"uuid": "473251b2-1ab4-4ce0-bfea-f97b3f8f6ebb", "name": "79beb2c9-bac5-4287-a9ef-9ce61c94224a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.246762625041277, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42085270345980447, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0891e070-d97c-48e0-ba7d-2b680fa93ce3", "name": "adaf6100-1d2d-4134-a35b-50bc5f41a61d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "473251b2-1ab4-4ce0-bfea-f97b3f8f6ebb"}}}]}, {"uuid": "85d88516-8681-4092-8522-e96e03808247", "name": "load_p1rlv787_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0089ee3-0cb4-434c-adc4-c91a8441ef0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0891e070-d97c-48e0-ba7d-2b680fa93ce3"}}}}, {"uuid": "65eaa6dd-e9ea-4531-b49b-9e6c44dfb463", "name": "fc3a09c9-d1fc-47ad-ba9f-e05638d984b6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.246762625041277, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42085270345980447, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5183e717-19d2-4093-a229-bfdecdd6a6b7", "name": "57ceeb5c-7caa-4188-ac3e-484dd9a20a93", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "65eaa6dd-e9ea-4531-b49b-9e6c44dfb463"}}}]}, {"uuid": "fa119cc4-4020-42a3-bed6-cb4c53fe15f7", "name": "load_p1rlv787_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0089ee3-0cb4-434c-adc4-c91a8441ef0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5183e717-19d2-4093-a229-bfdecdd6a6b7"}}}}, {"uuid": "7eb3f9c1-caf9-45b3-854a-b2e7498e6012", "name": "caa89576-3694-45c2-b0d2-dfa67d478a27_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8660061383019082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.44544683702444765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "30ce92a9-817f-477c-a08d-b1c98ef75f61", "name": "1f49a407-37ad-484a-8b93-f026dedbc504", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7eb3f9c1-caf9-45b3-854a-b2e7498e6012"}}}]}, {"uuid": "a6ef7793-92d0-4190-9487-746bd46b1fe3", "name": "load_p1rlv788_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9f470d9-6ead-4413-ad8a-7ccc69ae9237"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "30ce92a9-817f-477c-a08d-b1c98ef75f61"}}}}, {"uuid": "1fe997d5-481e-4bb5-886a-36f042ab7a4a", "name": "76064b24-cdad-4a93-b0aa-69817f67638c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8660061383019082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.44544683702444765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4b9db413-91c2-4b76-9e16-748421872017", "name": "f135eded-859b-48d6-a770-7d6ce70bceb3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1fe997d5-481e-4bb5-886a-36f042ab7a4a"}}}]}, {"uuid": "a1293b75-945a-4a8b-9e75-47fe77b2ac08", "name": "load_p1rlv788_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9f470d9-6ead-4413-ad8a-7ccc69ae9237"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4b9db413-91c2-4b76-9e16-748421872017"}}}}, {"uuid": "2995fa38-c796-407f-b921-aa40a63a21a5", "name": "da1c4ecf-5cec-4267-81c4-b45fc78f34d1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1146755706450526, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5956233891083068, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3f242781-55ca-45dc-80f0-7e15ad23a6ca", "name": "63e7d2cd-0504-4847-8012-5e2723d55f6a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2995fa38-c796-407f-b921-aa40a63a21a5"}}}]}, {"uuid": "07f0059d-15e9-4a01-9e08-bee0656f3c1b", "name": "load_p1rlv789_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9ce2439-fcc7-4965-81ee-f875db83b003"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3f242781-55ca-45dc-80f0-7e15ad23a6ca"}}}}, {"uuid": "cd40daea-6940-49fa-b2d8-685091be24c7", "name": "7cc7695b-9b9e-42fc-b8fd-de7fda9a3f7f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1146755706450526, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5956233891083068, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "abd3d946-ff0d-4c90-b67c-3a474857170f", "name": "cfc12075-8e2f-4e2d-9c71-5c99072bdd41", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cd40daea-6940-49fa-b2d8-685091be24c7"}}}]}, {"uuid": "8e04a276-1831-4a10-89ac-8e0cc810ac43", "name": "load_p1rlv789_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9ce2439-fcc7-4965-81ee-f875db83b003"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "abd3d946-ff0d-4c90-b67c-3a474857170f"}}}}, {"uuid": "67358195-51ef-441c-a590-de52ce404ae5", "name": "313602cc-e67f-4578-abdd-9f8eb3be2c03_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.507865878359724, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5977385470921427, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a32bf0e6-797a-4730-a940-ac2793a72dda", "name": "390e6fa0-70fa-4622-953b-612514c57b46", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "67358195-51ef-441c-a590-de52ce404ae5"}}}]}, {"uuid": "32d4ada8-ea2a-4266-9e2e-0aee1c3746c3", "name": "load_p1rlv790_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf42fa7f-370e-400e-8f6d-76eb8c70ecb9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a32bf0e6-797a-4730-a940-ac2793a72dda"}}}}, {"uuid": "059c12b8-7a4d-474e-b868-f82f1115f672", "name": "d3aa0c32-6da1-4087-b743-172cc3bf2a07_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.507865878359724, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5977385470921427, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bc4817fe-0da3-43f5-ad60-a477d7c8576b", "name": "2a94ff1c-f549-461e-8968-54329535288e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "059c12b8-7a4d-474e-b868-f82f1115f672"}}}]}, {"uuid": "cd07f9ea-7435-4b93-8fcc-a44d99da4aae", "name": "load_p1rlv790_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf42fa7f-370e-400e-8f6d-76eb8c70ecb9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bc4817fe-0da3-43f5-ad60-a477d7c8576b"}}}}, {"uuid": "f2079efb-f07c-41bc-94c2-584ae629605d", "name": "86210398-a9a8-4879-9e3c-b7e182dc94e5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.8801930784369265, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0115137645096066, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "58867ff1-aac8-41f5-a8f6-037f853e3cd6", "name": "72ae5231-2aed-4bdb-b71a-f9c042ea9b3f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f2079efb-f07c-41bc-94c2-584ae629605d"}}}]}, {"uuid": "6d6e5bd0-4069-4b2b-8a3b-a4b8156b0b6b", "name": "load_p1rlv791_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fe9bb3f-e3c1-4b59-b39f-f62271a55bdd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "58867ff1-aac8-41f5-a8f6-037f853e3cd6"}}}}, {"uuid": "cc6c614d-1f66-4f40-a958-de8b63523d00", "name": "1d8a2af4-40d4-47c0-a99f-71754c62732e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.8801930784369265, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0115137645096066, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d576a3e9-8707-405e-ad02-8b47148a6b96", "name": "458448a9-d21f-4598-ba66-2148ed15878b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cc6c614d-1f66-4f40-a958-de8b63523d00"}}}]}, {"uuid": "1fb64f7e-30c1-4b55-b646-32d6d63c9137", "name": "load_p1rlv791_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fe9bb3f-e3c1-4b59-b39f-f62271a55bdd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d576a3e9-8707-405e-ad02-8b47148a6b96"}}}}, {"uuid": "c8ca456b-103e-40a8-826f-9658b81c0c8c", "name": "a58593df-f306-44d4-956d-19bd50b79f7a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7628538083737542, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7287957147649712, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d505cfe9-c55f-44e1-a8d2-8b1fffbb1241", "name": "106e892e-878c-4a5c-ad20-d2887fbfb751", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c8ca456b-103e-40a8-826f-9658b81c0c8c"}}}]}, {"uuid": "31f2fd4f-1cac-4765-a201-816b91860a72", "name": "load_p1rlv792_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f806232e-0a52-46d5-80f7-7ea3a914137a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d505cfe9-c55f-44e1-a8d2-8b1fffbb1241"}}}}, {"uuid": "92485c07-f490-4bbc-a625-20051376dba7", "name": "e18075de-75e7-40cb-a8c4-29a5ff6f87ed_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7628538083737542, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7287957147649712, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "967be153-6d35-4c97-a427-d053a9ef357e", "name": "a2138130-423b-4e33-8b77-76ebb1b6dafa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "92485c07-f490-4bbc-a625-20051376dba7"}}}]}, {"uuid": "b24d80d1-0fb7-41c9-98d8-b2e48b6d99c1", "name": "load_p1rlv792_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f806232e-0a52-46d5-80f7-7ea3a914137a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "967be153-6d35-4c97-a427-d053a9ef357e"}}}}, {"uuid": "4f125316-f1dc-4264-a48a-3eb422837b73", "name": "ca0b469e-5b49-4e05-a6e6-f1796455c4fe_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3510125413548424, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5621017434083633, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7f3c53b7-1c9e-4f38-aa93-41bfe2410c5f", "name": "096b7ce4-2993-4f74-a691-64c767bd5807", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4f125316-f1dc-4264-a48a-3eb422837b73"}}}]}, {"uuid": "6624cffa-97dd-4f2f-a93c-6283af6764c1", "name": "load_p1rlv793_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e8c4bc9-0688-43e6-93a8-9664c9b618b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7f3c53b7-1c9e-4f38-aa93-41bfe2410c5f"}}}}, {"uuid": "48ff241c-9d0d-4e99-9630-c7c010dcbfc4", "name": "458cf665-3d81-4248-8d50-75e991f6dd7a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3510125413548424, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5621017434083633, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "25886f1d-2b99-4844-9818-12e1072e4078", "name": "fdb32a95-93af-4633-951a-7ce676661d31", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "48ff241c-9d0d-4e99-9630-c7c010dcbfc4"}}}]}, {"uuid": "ba48e384-469b-4bfe-b930-408e95243541", "name": "load_p1rlv793_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e8c4bc9-0688-43e6-93a8-9664c9b618b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "25886f1d-2b99-4844-9818-12e1072e4078"}}}}, {"uuid": "a433be39-5d29-46d5-af99-b5433f4eb28e", "name": "4cbdee84-762e-4ffe-b5ca-739d59c579f6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8660061383019082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.44544683702444765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "563fee7b-f9a7-4c21-ad96-84ff8c32ca24", "name": "794f19a1-12cb-4fd3-8a38-28db448457eb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a433be39-5d29-46d5-af99-b5433f4eb28e"}}}]}, {"uuid": "d4736669-6c0f-458e-b2bf-564059c09a88", "name": "load_p1rlv794_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eecc456-41af-4242-ab30-d8ca45d55a2c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "563fee7b-f9a7-4c21-ad96-84ff8c32ca24"}}}}, {"uuid": "ed90e9c2-75fc-4ccb-a6ea-9678e556a42b", "name": "fa8d3016-4cf5-4d13-b2fa-6e4f6cd801c1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8660061383019082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.44544683702444765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "46083046-bc68-4957-9762-f7c32f3ed87a", "name": "73f557bd-a82b-4859-a8a7-96565bb7ca35", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ed90e9c2-75fc-4ccb-a6ea-9678e556a42b"}}}]}, {"uuid": "77460682-1d6c-4df8-8eae-c8393e31aca8", "name": "load_p1rlv794_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eecc456-41af-4242-ab30-d8ca45d55a2c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "46083046-bc68-4957-9762-f7c32f3ed87a"}}}}, {"uuid": "6c710181-e2b6-4826-b884-cb0d10b219a0", "name": "253e183e-ba89-4e13-b8ad-ff127796e36c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.083951745833768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9853982282300497, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0653bc01-11d5-4990-9a66-94333ae0f39e", "name": "94bdb433-37d8-4f57-8525-84aec78cf6a4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c710181-e2b6-4826-b884-cb0d10b219a0"}}}]}, {"uuid": "1842e1ea-1f3a-44f6-86da-050c29265f33", "name": "load_p1rlv795_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb137176-0642-4d87-ae40-1b7b0e1cb214"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0653bc01-11d5-4990-9a66-94333ae0f39e"}}}}, {"uuid": "c9e78314-1f2b-48b3-86db-2504aa47b9d1", "name": "517dfb60-554d-4efb-95e7-209b287750bd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.083951745833768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9853982282300497, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e17db933-2332-4184-acb3-983d9976b88d", "name": "00024c62-6f74-4838-ac6f-c4e4ab032493", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9e78314-1f2b-48b3-86db-2504aa47b9d1"}}}]}, {"uuid": "11d0c30a-c620-42e1-9c1b-108bbaf9c2c8", "name": "load_p1rlv795_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb137176-0642-4d87-ae40-1b7b0e1cb214"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e17db933-2332-4184-acb3-983d9976b88d"}}}}, {"uuid": "dd4817ff-9567-48fc-a612-d4f252b795a5", "name": "34accbdf-746d-4883-9760-04afcf68e08e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0085854932437286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7150296414254909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "755376c1-8d90-4413-bb42-962c9347ffbf", "name": "29e47ff3-8353-40ff-8f54-01b484e9267c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dd4817ff-9567-48fc-a612-d4f252b795a5"}}}]}, {"uuid": "32b85a02-d101-4205-852e-f12e6d5349e0", "name": "load_p1rlv796_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59662cef-c126-4188-ad86-844f6cabaf34"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "755376c1-8d90-4413-bb42-962c9347ffbf"}}}}, {"uuid": "d09ed02f-0edd-4bc2-83fd-f36c855f6ec6", "name": "764f4a73-d05f-4d60-9bd3-bf7d1e36c0e1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0085854932437286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7150296414254909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "79449805-4e72-494a-87d2-57dad2817656", "name": "7bba4b8f-3ec6-4e8c-bf7d-471827c3cd54", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d09ed02f-0edd-4bc2-83fd-f36c855f6ec6"}}}]}, {"uuid": "44f27ce1-c9f1-4f28-a727-53e65be90070", "name": "load_p1rlv796_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59662cef-c126-4188-ad86-844f6cabaf34"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "79449805-4e72-494a-87d2-57dad2817656"}}}}, {"uuid": "b5f8d76c-a753-4d81-b731-5d3dff6e99d9", "name": "5a907586-3b6b-44f9-b487-1a3d596627ed_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.127438645009231, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8176304041402817, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c6a0a7a4-5fe0-4b41-8a8f-0a33c6123d0b", "name": "0926481c-375c-45c6-8bc9-796e6fccc09b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5f8d76c-a753-4d81-b731-5d3dff6e99d9"}}}]}, {"uuid": "a12f00cb-3c93-410c-a003-2b94e48aeec0", "name": "load_p1rlv797_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b1c34f1-2613-46aa-9a9f-686ee518e559"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c6a0a7a4-5fe0-4b41-8a8f-0a33c6123d0b"}}}}, {"uuid": "1518672b-3dd9-496d-8565-f93c0eed2369", "name": "7a4a591f-f997-471d-ab7e-16e7d400ace9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.127438645009231, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8176304041402817, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a47ee959-4933-4ad4-ae2c-7fe6b20ce82a", "name": "ac50e232-492f-46d1-8e34-e3bfc191470b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1518672b-3dd9-496d-8565-f93c0eed2369"}}}]}, {"uuid": "cf856919-7fc5-4818-8d6f-28087f021ebe", "name": "load_p1rlv797_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b1c34f1-2613-46aa-9a9f-686ee518e559"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a47ee959-4933-4ad4-ae2c-7fe6b20ce82a"}}}}, {"uuid": "d4417dbc-b4db-49bd-8feb-627965850552", "name": "7bd8265e-cdf2-4bc7-ad3d-09ac6aeb4d16_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.839033632547656, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.36892018645953045, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b7b0c9cb-b446-4f62-9873-638405bd7a3d", "name": "437537d8-a0dd-416a-a449-1a6a634f5d26", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d4417dbc-b4db-49bd-8feb-627965850552"}}}]}, {"uuid": "1a71adb8-ddc6-4746-9b53-90cfd4bf60ac", "name": "load_p1rlv798_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c30005d7-7e42-4a08-8935-0c7227fba4a6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b7b0c9cb-b446-4f62-9873-638405bd7a3d"}}}}, {"uuid": "86ef5b5f-77f6-450d-b85a-2d57d870054c", "name": "9345b937-0745-4a39-8b8e-cca85f4d14b4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.839033632547656, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.36892018645953045, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6df4ee25-a6ea-4b19-9eeb-8e5124bd1fdf", "name": "335aa7fd-9a7a-43c0-94a5-69d03ad5089a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "86ef5b5f-77f6-450d-b85a-2d57d870054c"}}}]}, {"uuid": "475ac95f-30e7-4ab2-b9f6-97693f55195d", "name": "load_p1rlv798_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c30005d7-7e42-4a08-8935-0c7227fba4a6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6df4ee25-a6ea-4b19-9eeb-8e5124bd1fdf"}}}}, {"uuid": "27620e64-36f4-40ba-978e-de18bc4e532b", "name": "62e4942b-d3a0-498c-948a-12e3b7f8dcad_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.046232297850773, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7285366000251032, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cac38115-fa29-4a33-b1ef-955dc8b3b3f4", "name": "4ddf73be-47d5-41d8-a0af-f1089e7f3fa8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "27620e64-36f4-40ba-978e-de18bc4e532b"}}}]}, {"uuid": "ed1b18d9-960b-4b41-9994-578e21b4add9", "name": "load_p1rlv799_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f706d9d-0cb1-453b-9ca5-377f7d766099"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cac38115-fa29-4a33-b1ef-955dc8b3b3f4"}}}}, {"uuid": "58b99372-8eba-4bfd-9257-73cafdb761d2", "name": "fe6be4cf-f2be-4f13-9b0d-2925c42f365e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.046232297850773, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7285366000251032, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "09e0bc18-e092-4871-9310-559dd3979e4f", "name": "afbdf141-92fc-44c6-8829-317e342e3cd2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58b99372-8eba-4bfd-9257-73cafdb761d2"}}}]}, {"uuid": "191e9bea-c480-48d9-95bb-178ae994ab05", "name": "load_p1rlv799_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f706d9d-0cb1-453b-9ca5-377f7d766099"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "09e0bc18-e092-4871-9310-559dd3979e4f"}}}}, {"uuid": "cdc15692-4ad5-4014-a5ed-35a494709340", "name": "9a65e01b-2a25-4c33-9767-a0c5f3a169d9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2795803428770153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1698974287191981, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "30c757e1-f5f5-478f-8cfe-1b6a8ad5bf87", "name": "238dc65a-8496-493e-ba24-9caa91cdd716", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cdc15692-4ad5-4014-a5ed-35a494709340"}}}]}, {"uuid": "e20c0dc1-5195-4f50-8e05-0dd4080c5b83", "name": "load_p1rlv800_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3126c61-9602-45cf-8d57-27d26c14ca7e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "30c757e1-f5f5-478f-8cfe-1b6a8ad5bf87"}}}}, {"uuid": "f8b39291-b936-4c7e-a0c8-c43db1817944", "name": "7f80a2f3-4e2c-4048-bf17-54d0f67df2f1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2795803428770153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1698974287191981, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d540a418-a6ec-4518-bc0e-61fc04cc42b2", "name": "ae58a800-02f8-4f30-a632-f7d4f32f9846", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8b39291-b936-4c7e-a0c8-c43db1817944"}}}]}, {"uuid": "4cbeba7c-b5dd-4e8f-bbee-7081b2b5b5f8", "name": "load_p1rlv800_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3126c61-9602-45cf-8d57-27d26c14ca7e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d540a418-a6ec-4518-bc0e-61fc04cc42b2"}}}}, {"uuid": "e25eb9c7-da87-4f68-9322-79e1381c82c9", "name": "4a7ac419-9d21-4faa-bf7a-df40e3c17cc5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2142575595505583, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8511261488468437, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c1b13cd-f503-4295-800a-46586da7cbaa", "name": "d29ba3ab-cbae-4437-9a3a-154ba2c85de5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e25eb9c7-da87-4f68-9322-79e1381c82c9"}}}]}, {"uuid": "d1a79f47-823e-489e-9102-bfd8661a0698", "name": "load_p1rlv801_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ecc45b2-1fbe-4a31-995f-e2f8fffe61a7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c1b13cd-f503-4295-800a-46586da7cbaa"}}}}, {"uuid": "7c34c779-171c-4a0e-9e87-e7988cb61122", "name": "0ab8dd7e-65d8-4fd1-a56e-86ebbc67d9a5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2142575595505583, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8511261488468437, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "620ff808-897f-4bb3-8cf6-1a3e02e6a00d", "name": "7b4b2a27-3f17-4c47-bda6-8f9c0aaf4e06", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7c34c779-171c-4a0e-9e87-e7988cb61122"}}}]}, {"uuid": "04816d23-d595-4b23-9d7c-736dd614d965", "name": "load_p1rlv801_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ecc45b2-1fbe-4a31-995f-e2f8fffe61a7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "620ff808-897f-4bb3-8cf6-1a3e02e6a00d"}}}}, {"uuid": "6a83fbb7-afe1-47d8-b2da-92214e07d67a", "name": "b078b8bf-7601-453e-a44d-d6208a434655_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.621947646480353, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0332384495271123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9b9deaaf-bc34-40fb-82b1-6502cd1d6393", "name": "c5ab4f42-4ac5-43ff-9588-89aa16263451", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6a83fbb7-afe1-47d8-b2da-92214e07d67a"}}}]}, {"uuid": "226177fd-fc5f-43d1-92ad-aa76bcd7f486", "name": "load_p1rlv802_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2436086-d5c4-4b70-a402-e7d1b6f5b77e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9b9deaaf-bc34-40fb-82b1-6502cd1d6393"}}}}, {"uuid": "edadc232-577f-4196-9c92-4982f9b32db8", "name": "a8b3a10b-50ff-4be6-b58b-612ba1efca1d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.621947646480353, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0332384495271123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f8c9d64d-a92c-4fab-a690-34c10f1e6876", "name": "de4abd99-b477-48f0-854d-a5de0fbab94f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "edadc232-577f-4196-9c92-4982f9b32db8"}}}]}, {"uuid": "5513bc2f-7647-49ad-acf0-cad7dc4344b8", "name": "load_p1rlv802_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2436086-d5c4-4b70-a402-e7d1b6f5b77e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f8c9d64d-a92c-4fab-a690-34c10f1e6876"}}}}, {"uuid": "4a6e72dc-0fd5-4a6d-a760-6bca463c7958", "name": "2d097c22-693f-465b-ab51-97c98658be1b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.991433457795887, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5982568468826307, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "93e40e12-3a0b-4142-b1b8-2798f6023a59", "name": "6324b962-f7ac-4458-92f4-14eff840fa9d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4a6e72dc-0fd5-4a6d-a760-6bca463c7958"}}}]}, {"uuid": "1a518b9a-23c3-404f-8aa6-9fef87d86748", "name": "load_p1rlv803_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "018c978c-5673-4090-9792-b75ee161f6d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "93e40e12-3a0b-4142-b1b8-2798f6023a59"}}}}, {"uuid": "f1d9e12c-3c70-4e12-b43a-42993ad845bf", "name": "4584a0d0-a1a7-4113-89fd-c3670eef0f71_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.991433457795887, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5982568468826307, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "13304da8-6eed-4a95-be24-9c06f1773a88", "name": "40305169-1355-4f4b-b05e-9a9f83d02553", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f1d9e12c-3c70-4e12-b43a-42993ad845bf"}}}]}, {"uuid": "4119dd23-3bfa-4b70-a7b2-b5cfe56c9ba1", "name": "load_p1rlv803_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "018c978c-5673-4090-9792-b75ee161f6d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "13304da8-6eed-4a95-be24-9c06f1773a88"}}}}, {"uuid": "c1fb01ee-0a2a-408e-b93d-63b1e0ae075c", "name": "0453fe34-a68d-4aa6-b3f3-f8be97681717_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.292799122473319, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5385753507809203, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f3134e33-7b18-431b-b107-337c262ecfb1", "name": "c1f9910b-dff3-4cd6-a77d-a29738ad9094", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c1fb01ee-0a2a-408e-b93d-63b1e0ae075c"}}}]}, {"uuid": "22899ffe-ad39-4be8-963a-658a3c025e92", "name": "load_p1rlv804_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a11ba246-99d9-4cf5-a557-bec53c75e6fb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f3134e33-7b18-431b-b107-337c262ecfb1"}}}}, {"uuid": "0577474f-713e-42a1-8360-6b5315691b7b", "name": "841c637a-f73e-4be3-851d-44ee71e33f7e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.292799122473319, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5385753507809203, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a70eccf7-9561-45ff-8e98-edcb8caddc1c", "name": "0bfa7b8d-3957-40b6-a517-47cc3bccd8c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0577474f-713e-42a1-8360-6b5315691b7b"}}}]}, {"uuid": "0d0dfa2c-b47a-4f09-894d-383a0abaa69f", "name": "load_p1rlv804_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a11ba246-99d9-4cf5-a557-bec53c75e6fb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a70eccf7-9561-45ff-8e98-edcb8caddc1c"}}}}, {"uuid": "cb90b3f2-2054-4a12-9bc1-174278764562", "name": "482d07e2-73a2-47d8-8077-9f733d11d325_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.987999469244499, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42543082019456707, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "02b2e4ae-c602-4a01-8dd0-8d4927f5c6bc", "name": "5f096ec6-979d-4f96-b37f-e4c023012d2c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cb90b3f2-2054-4a12-9bc1-174278764562"}}}]}, {"uuid": "94306602-9d91-4717-ac32-7601a7eec3a6", "name": "load_p1rlv805_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0475b34e-14ab-48e4-9df7-7444de1cde7d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "02b2e4ae-c602-4a01-8dd0-8d4927f5c6bc"}}}}, {"uuid": "e6faa0df-44b4-4ab4-918b-1ac3460b4f1a", "name": "354eb4e2-ce6d-4c16-bebc-38a7c83ac69b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.987999469244499, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42543082019456707, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9d416776-a183-456b-b3f3-1e4c13d23875", "name": "0e5a2587-eec9-45b4-b4aa-e20da2ae3c80", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e6faa0df-44b4-4ab4-918b-1ac3460b4f1a"}}}]}, {"uuid": "7f0817b8-99e8-4e61-bae4-015564a8978b", "name": "load_p1rlv805_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0475b34e-14ab-48e4-9df7-7444de1cde7d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9d416776-a183-456b-b3f3-1e4c13d23875"}}}}, {"uuid": "a1ae1f2a-6525-4488-8ddb-939e2c0a6bd9", "name": "86da67d3-dce4-40fa-924a-bfd2f591e54f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4950137537296666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31506625700854357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1176d2d0-4537-427d-99f7-59a44be17d94", "name": "db2b683a-b000-4b9c-9f6c-6fa3b027495e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a1ae1f2a-6525-4488-8ddb-939e2c0a6bd9"}}}]}, {"uuid": "09209c20-e17c-4675-b697-6afbacbb6e84", "name": "load_p1rlv806_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d9f269a-e476-4b82-a258-479d812d008d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1176d2d0-4537-427d-99f7-59a44be17d94"}}}}, {"uuid": "449e2e01-3cda-4040-bc51-39368c4a4046", "name": "a35047b0-fa29-4029-8d3a-5db7b73ea064_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4950137537296666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31506625700854357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7b3eeaba-f61b-4142-ae6e-89b24fce4547", "name": "a1528b96-8255-40de-8286-0171a4fe4581", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "449e2e01-3cda-4040-bc51-39368c4a4046"}}}]}, {"uuid": "dcc8b148-384f-4fa3-812b-52a49190219f", "name": "load_p1rlv806_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d9f269a-e476-4b82-a258-479d812d008d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7b3eeaba-f61b-4142-ae6e-89b24fce4547"}}}}, {"uuid": "71b51c74-d6e6-4e69-ac4a-677a95d0675a", "name": "21e2b630-e823-42b6-bf6d-863135e0c886_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.107858967059457, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3651352875232526, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ed616a72-ab12-4ce3-bace-d557ffc4cf34", "name": "e5242d07-16b8-465d-a1e4-90a257ee9cd7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "71b51c74-d6e6-4e69-ac4a-677a95d0675a"}}}]}, {"uuid": "fa476b20-630e-4d59-9f0f-a8d14a86554f", "name": "load_p1rlv807_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa259be8-8a61-461a-9e58-d4aaf1ce82db"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ed616a72-ab12-4ce3-bace-d557ffc4cf34"}}}}, {"uuid": "72f20477-33d2-4d5f-98ed-d5010b124c54", "name": "6ffe1ec2-6fcf-4f97-87fc-26865a0b7b7e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.107858967059457, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3651352875232526, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8b348d9f-802d-4db1-af83-c40d16a11169", "name": "54895934-cecc-4d92-8979-d00e62ba2e97", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72f20477-33d2-4d5f-98ed-d5010b124c54"}}}]}, {"uuid": "1d5c684d-9e7e-4e27-9f6c-89984f50cbb4", "name": "load_p1rlv807_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa259be8-8a61-461a-9e58-d4aaf1ce82db"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8b348d9f-802d-4db1-af83-c40d16a11169"}}}}, {"uuid": "10863d87-e2c5-4f8a-95c4-f779a208f6d2", "name": "cd9fef9d-a919-4b00-921e-8c2298a2343b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.847886228314274, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0445060168814917, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9d60dc14-18d9-41dc-bac8-1dc54d1cdd83", "name": "c37b3af4-0023-4302-82e0-be5197005d2b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "10863d87-e2c5-4f8a-95c4-f779a208f6d2"}}}]}, {"uuid": "c3bf69ee-2387-463a-a620-8889c6e696ed", "name": "load_p1rlv808_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dcb86a4-e6d7-48b4-b5c2-904635de271b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9d60dc14-18d9-41dc-bac8-1dc54d1cdd83"}}}}, {"uuid": "0ff26188-9f62-4401-8eaf-cfb058a40d76", "name": "f8daf638-4988-4e32-a558-2f17ccc10c4c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.847886228314274, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0445060168814917, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1108b691-7c26-477f-9c44-852d57e6c28a", "name": "36964797-4a01-4e6b-8193-17fdf9418144", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0ff26188-9f62-4401-8eaf-cfb058a40d76"}}}]}, {"uuid": "275d8b4b-180a-4ba5-8afe-6c5a984f910e", "name": "load_p1rlv808_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dcb86a4-e6d7-48b4-b5c2-904635de271b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1108b691-7c26-477f-9c44-852d57e6c28a"}}}}, {"uuid": "b90c43fd-9545-43d5-aa26-284f131d6951", "name": "fadbe899-067e-4fda-bd48-0fcb3363d23c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.739385174805638, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.976019322648958, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "861fff20-0acd-41c1-a98a-ffd197592db2", "name": "5c1659e7-028e-4567-bd50-da2566583a1d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b90c43fd-9545-43d5-aa26-284f131d6951"}}}]}, {"uuid": "9b75a966-d766-4da4-b3a9-99bb64317eaa", "name": "load_p1rlv809_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e0f8ee8-795f-4bea-bf7a-e2c477eefb89"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "861fff20-0acd-41c1-a98a-ffd197592db2"}}}}, {"uuid": "67a83380-fd27-4dbf-9f41-5025a8c30e9d", "name": "c4165a6b-63a1-4dbf-b432-ba5eb71b30bd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.739385174805638, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.976019322648958, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a2dcb90f-3ae2-411f-9321-5e5cf47b9fe9", "name": "1d108e2d-210d-4c1b-8fea-98eaaaac21cd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "67a83380-fd27-4dbf-9f41-5025a8c30e9d"}}}]}, {"uuid": "3f913e9e-d1c1-4fff-b236-303d44b401dc", "name": "load_p1rlv809_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e0f8ee8-795f-4bea-bf7a-e2c477eefb89"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a2dcb90f-3ae2-411f-9321-5e5cf47b9fe9"}}}}, {"uuid": "411f0651-0785-4e4f-99cc-b3715b12ea36", "name": "c1c6ca54-dd95-46f0-b798-4c803fd7167e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8309189378455104, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6069744647018672, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "03f741ce-96ad-4a1b-8277-ce411a51c68b", "name": "c368e4cc-7046-4395-bb00-5dce2f763b1b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "411f0651-0785-4e4f-99cc-b3715b12ea36"}}}]}, {"uuid": "28a09673-3ba1-4c43-9c43-3b7aa624b2a8", "name": "load_p1rlv810_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb4a881f-684d-48e4-a6f0-5832f73d140a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "03f741ce-96ad-4a1b-8277-ce411a51c68b"}}}}, {"uuid": "7901af69-6f57-4a73-b623-9e63c9300013", "name": "d8d7a554-5a06-4356-8cd0-15d4eb3e4a88_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8309189378455104, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6069744647018672, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f103a8ea-9301-4fda-81c7-a2f0b00444ea", "name": "0c4a7bcb-a22e-4fa1-abc1-71508477e6a6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7901af69-6f57-4a73-b623-9e63c9300013"}}}]}, {"uuid": "9704a4db-8a6e-4150-a7a1-4434d753063b", "name": "load_p1rlv810_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb4a881f-684d-48e4-a6f0-5832f73d140a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f103a8ea-9301-4fda-81c7-a2f0b00444ea"}}}}, {"uuid": "58540381-46f0-4842-b1f7-6f12c33c1aaa", "name": "3a3f1738-9558-40b1-803f-36ade87a88d0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7362273540893955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24527287728713068, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "535428b8-7298-4e27-8f95-a29be5db7f75", "name": "69a403d1-f846-495a-8ee7-1090e160611e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58540381-46f0-4842-b1f7-6f12c33c1aaa"}}}]}, {"uuid": "6aa9335f-11aa-4850-b488-a3b57ff0810c", "name": "load_p1rlv811_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "052949b1-9e85-4be7-993c-9e97efda3657"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "535428b8-7298-4e27-8f95-a29be5db7f75"}}}}, {"uuid": "d8097276-eed1-4787-91df-157c2fe5246c", "name": "74da4ae4-969e-4389-ba97-5e937297c4b4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7362273540893955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24527287728713068, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ff4d4f14-c6e8-4311-97fb-9a84145923c4", "name": "590a0c92-c812-41de-ae77-37676b1dd971", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d8097276-eed1-4787-91df-157c2fe5246c"}}}]}, {"uuid": "5e75c977-5c96-49b7-b33e-bd0dddd5db3b", "name": "load_p1rlv811_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "052949b1-9e85-4be7-993c-9e97efda3657"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ff4d4f14-c6e8-4311-97fb-9a84145923c4"}}}}, {"uuid": "d9c9c1f7-9a73-43ad-89bd-318929ad3ab7", "name": "1069ede5-9826-4402-8e4a-ceb7acb95f5b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0599252267318962, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3748861224482183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50152347-5bdb-49be-b9e0-01759af6ed74", "name": "b2bf3543-58fa-4099-9477-15cd1ff1a0b7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d9c9c1f7-9a73-43ad-89bd-318929ad3ab7"}}}]}, {"uuid": "82dea5fe-cd3a-42bd-a5f2-9d088a939774", "name": "load_p1rlv812_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26fea867-af5f-4213-b9c3-487975d1285e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50152347-5bdb-49be-b9e0-01759af6ed74"}}}}, {"uuid": "4c83845b-74b7-4ab5-8191-373fe40720fd", "name": "6faaffee-3331-4355-aa1e-1c718446170d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0599252267318962, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3748861224482183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "667a104b-536d-42cb-816c-35a837cf2f9c", "name": "f4293f81-a29c-4b0d-9b5e-0819f2ea6af3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4c83845b-74b7-4ab5-8191-373fe40720fd"}}}]}, {"uuid": "d01e44be-07f1-4f33-9f4d-b8b64c9f8c4e", "name": "load_p1rlv812_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26fea867-af5f-4213-b9c3-487975d1285e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "667a104b-536d-42cb-816c-35a837cf2f9c"}}}}, {"uuid": "74c8e1af-8f80-4b63-8126-b89b014016fe", "name": "80123125-5b25-452c-aa68-8772e6db11d1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7457942211533133, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8784341351558463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bc2a2099-56de-42de-8494-e78cc7abf913", "name": "3f111631-2636-4a5d-95d6-45a74a6c73c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "74c8e1af-8f80-4b63-8126-b89b014016fe"}}}]}, {"uuid": "c527ba67-9ea4-4e8e-b824-7e21912984ae", "name": "load_p1rlv813_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10d44b60-55c0-4d78-abbb-52c8cd67134b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bc2a2099-56de-42de-8494-e78cc7abf913"}}}}, {"uuid": "76e54313-3a38-4657-9e11-ca3a54a65c86", "name": "6e582f0d-b6ca-41f6-9d92-3c66c8efced8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7457942211533133, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8784341351558463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7bd4b1d3-e002-4251-8d5f-b1ab9b73ea9f", "name": "2547f8ca-a395-4e67-854e-078bfad68612", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "76e54313-3a38-4657-9e11-ca3a54a65c86"}}}]}, {"uuid": "020e8cbe-3954-4821-8e3a-e5aeec53bd36", "name": "load_p1rlv813_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10d44b60-55c0-4d78-abbb-52c8cd67134b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7bd4b1d3-e002-4251-8d5f-b1ab9b73ea9f"}}}}, {"uuid": "58ad71a3-0c2d-44a6-b0ee-7505907d451c", "name": "852e816c-ea4f-467b-8a6e-39eccd098c5c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.559104904760759, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9054328372998879, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "67877123-5ca0-4a19-a3b5-dd96d917765e", "name": "4a6c75be-9ab3-4470-b580-fb976de83b81", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58ad71a3-0c2d-44a6-b0ee-7505907d451c"}}}]}, {"uuid": "35d25ebf-a90f-48cc-8646-7ffa7626e103", "name": "load_p1rlv814_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b8065f3-8286-4f99-aa56-b9b631a2f838"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "67877123-5ca0-4a19-a3b5-dd96d917765e"}}}}, {"uuid": "bc3882ff-f092-48c8-bfeb-1052dde4966e", "name": "12d12581-ea08-41f0-971d-8554dadfd08d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.559104904760759, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9054328372998879, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0280bd4b-f7b8-455d-b020-1545d7160332", "name": "a5919842-32a2-4d76-9d02-bdb0b1001d6f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bc3882ff-f092-48c8-bfeb-1052dde4966e"}}}]}, {"uuid": "64cf4715-7576-460b-a418-5f1026488522", "name": "load_p1rlv814_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b8065f3-8286-4f99-aa56-b9b631a2f838"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0280bd4b-f7b8-455d-b020-1545d7160332"}}}}, {"uuid": "16ea51e7-cc44-48d1-ae9b-8225235d9388", "name": "0614d656-6794-4b42-b0fc-736838c79079_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5424601784243566, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31457775613808403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0bba08a5-c480-4c68-91bd-ee13541689d4", "name": "d5448476-a6b8-4f95-9116-644f14416659", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "16ea51e7-cc44-48d1-ae9b-8225235d9388"}}}]}, {"uuid": "f74b3e0a-a07f-41e6-aebd-8ab1b254bb5b", "name": "load_p1rlv815_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a134556-828b-4e0c-8773-2f207802e33a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0bba08a5-c480-4c68-91bd-ee13541689d4"}}}}, {"uuid": "ad0b2281-280e-4076-8064-667a6d21ed4f", "name": "de19320e-a7de-4eb0-99aa-bfe8567f4a97_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5424601784243566, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31457775613808403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f2d71091-b353-43e0-8aa5-403a8f7cb0b4", "name": "4275bf63-4eb4-4851-96cb-99b331938601", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ad0b2281-280e-4076-8064-667a6d21ed4f"}}}]}, {"uuid": "6e68ad30-1e54-48c4-91e8-bf82491286e3", "name": "load_p1rlv815_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a134556-828b-4e0c-8773-2f207802e33a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f2d71091-b353-43e0-8aa5-403a8f7cb0b4"}}}}, {"uuid": "cc6a60b4-daec-4a6e-9d12-9ae8392dd142", "name": "63c541fe-b2e0-4195-add5-1638ee13af84_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.357764823379774, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7869023210214492, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b2886171-89c1-477c-83a0-d51f6cb7b994", "name": "3bf69e6f-2184-4351-891b-529fb58f8505", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cc6a60b4-daec-4a6e-9d12-9ae8392dd142"}}}]}, {"uuid": "1d166bab-8038-4240-bd6a-990676496f71", "name": "load_p1rlv816_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d6de7c2-fd2c-4071-8e90-1513f521cf87"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b2886171-89c1-477c-83a0-d51f6cb7b994"}}}}, {"uuid": "29adaec0-7aae-48a3-ab81-8e9adb2b7dd8", "name": "5b8fe093-71c0-4840-b92f-1c8335949f70_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.357764823379774, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7869023210214492, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "edc520af-667a-4ee9-b69c-602f2ee46cd9", "name": "57027629-6e91-4bed-bfee-cbdba2e2ee83", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "29adaec0-7aae-48a3-ab81-8e9adb2b7dd8"}}}]}, {"uuid": "f806dba9-9864-4a17-98e6-8c7e5e404f25", "name": "load_p1rlv816_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d6de7c2-fd2c-4071-8e90-1513f521cf87"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "edc520af-667a-4ee9-b69c-602f2ee46cd9"}}}}, {"uuid": "40ec427d-4957-4781-9f16-defc4fee8c6c", "name": "275b825d-0d85-47d5-80e1-e7f977a40dcb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1206689642843692, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34257205075767067, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f2e22e49-ad98-46fc-b3f6-b9815b9ab095", "name": "2c11f1b6-aa7c-40a6-b8b2-4e732406033b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "40ec427d-4957-4781-9f16-defc4fee8c6c"}}}]}, {"uuid": "75abaeea-16a0-4cc7-aec6-20c6a7b98961", "name": "load_p1rlv817_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11064c6f-3b7a-43b5-96ca-7ef96be3815e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f2e22e49-ad98-46fc-b3f6-b9815b9ab095"}}}}, {"uuid": "fdebb9b4-7dad-44e1-89fa-07845bbeafad", "name": "55c9250e-e64e-4954-8dbf-d93791a576e9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1206689642843692, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34257205075767067, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aae121fb-b12e-4312-b17b-f4a5fe5a6853", "name": "04384dfc-7214-4f2b-b449-060dc7a9c122", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fdebb9b4-7dad-44e1-89fa-07845bbeafad"}}}]}, {"uuid": "4c88d4b3-eeee-49c9-8200-c22d72a7e5c1", "name": "load_p1rlv817_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11064c6f-3b7a-43b5-96ca-7ef96be3815e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aae121fb-b12e-4312-b17b-f4a5fe5a6853"}}}}, {"uuid": "6cfcc2d1-35cc-4487-9fad-d776a52e44a4", "name": "546d460b-d910-4839-bab8-8fa5e7633188_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6669289783709, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.056901546523703654, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "03355bda-6ec3-41d7-bd7e-561878806338", "name": "7515a17d-db96-49cb-92eb-82f1034f0bfb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6cfcc2d1-35cc-4487-9fad-d776a52e44a4"}}}]}, {"uuid": "4dfc5955-660e-4595-a330-c040395a985c", "name": "load_p1rlv818_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd8c54fd-14d4-46fa-8bef-59c1097d5026"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "03355bda-6ec3-41d7-bd7e-561878806338"}}}}, {"uuid": "22c85500-9369-41ae-b2fd-df9cf5491168", "name": "c0d8a78f-2c84-47e6-a6f1-4539baf2a4c1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6669289783709, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.056901546523703654, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5ec7b202-9be4-4f06-90dd-c373fd66e271", "name": "18450587-18dd-495a-b503-26c3b7666697", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "22c85500-9369-41ae-b2fd-df9cf5491168"}}}]}, {"uuid": "5b11581f-6f3b-4e07-9631-582873c4ad2d", "name": "load_p1rlv818_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd8c54fd-14d4-46fa-8bef-59c1097d5026"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5ec7b202-9be4-4f06-90dd-c373fd66e271"}}}}, {"uuid": "29b9d5df-74fd-4d30-b8db-b1dc6baf59c5", "name": "700c68e8-f6bd-4e87-83ee-f0234d7744c5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.195601026095605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4379463760124337, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fe86b1ac-9749-4799-8245-57e5a38f23cb", "name": "01909453-2a47-428b-95f7-da66d28dbf70", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "29b9d5df-74fd-4d30-b8db-b1dc6baf59c5"}}}]}, {"uuid": "89ca12ad-7ca6-44eb-844b-402ac986d9ed", "name": "load_p1rlv819_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "def7e507-cb62-42f5-8451-b8a742ef4eb2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fe86b1ac-9749-4799-8245-57e5a38f23cb"}}}}, {"uuid": "2c2b7e63-bd59-4911-9dff-b60fb2ca9df0", "name": "9d2c38c2-cc88-474b-97b5-d32bf1220fb9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.195601026095605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4379463760124337, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9d7081f1-3610-4720-83ee-674d84afb519", "name": "deb735ed-88c7-483c-972c-ef5226dc0706", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2c2b7e63-bd59-4911-9dff-b60fb2ca9df0"}}}]}, {"uuid": "2360163a-c6ae-4a56-8b0f-268bf5d7f355", "name": "load_p1rlv819_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "def7e507-cb62-42f5-8451-b8a742ef4eb2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9d7081f1-3610-4720-83ee-674d84afb519"}}}}, {"uuid": "359e99f9-c749-4a63-9430-3d7d1687bf3a", "name": "dc8fcfe6-1b8d-4b27-9304-228eafb3bea7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.008167500419157, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.871384812064858, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "08081de5-092d-418d-8bf1-7a0776a98115", "name": "d6882342-2d99-4ee8-8620-51e18126df5d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "359e99f9-c749-4a63-9430-3d7d1687bf3a"}}}]}, {"uuid": "61583365-45ef-467f-bb32-f91025a8734e", "name": "load_p1rlv820_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41e1e576-4cc9-4fea-9d87-d436f000a675"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "08081de5-092d-418d-8bf1-7a0776a98115"}}}}, {"uuid": "2069248f-6ee1-48af-aef7-8148d4d28b60", "name": "f63716d2-ce08-4e7a-984e-76afa17927f9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.008167500419157, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.871384812064858, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2f52cef4-03b0-41b0-9cd8-e2ac77c6d1ca", "name": "f96170a8-efbe-4507-b6e8-ecf270701de9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2069248f-6ee1-48af-aef7-8148d4d28b60"}}}]}, {"uuid": "c8915dd6-3369-4fb4-acb5-5a4cd2081813", "name": "load_p1rlv820_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41e1e576-4cc9-4fea-9d87-d436f000a675"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2f52cef4-03b0-41b0-9cd8-e2ac77c6d1ca"}}}}, {"uuid": "924ed092-c747-45a6-83f1-d75008562baf", "name": "e48461e1-8dc1-479e-b509-d84abb5c5a92_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4363904318707768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7717292253609904, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3f825a39-24df-424e-9e0a-f0438f84d933", "name": "77fe357d-9cfb-4a07-82ac-389991596cde", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "924ed092-c747-45a6-83f1-d75008562baf"}}}]}, {"uuid": "516e8fd2-c4d4-49cd-b34a-7d09cbed8e5c", "name": "load_p1rlv821_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5578d8b4-7c1e-444f-8d27-8c9bf733f420"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3f825a39-24df-424e-9e0a-f0438f84d933"}}}}, {"uuid": "625516ba-61e6-4261-a54c-2f53d81cb1e4", "name": "43a1433d-0afd-42b1-988d-c93b6e2936e8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4363904318707768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7717292253609904, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "93d746a0-40ed-4eeb-a100-03d3b7d228dd", "name": "efadacd5-7018-4c44-8c40-90ffd6627a3e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "625516ba-61e6-4261-a54c-2f53d81cb1e4"}}}]}, {"uuid": "025864c7-1d2b-4f23-a563-57f117b54b95", "name": "load_p1rlv821_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5578d8b4-7c1e-444f-8d27-8c9bf733f420"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "93d746a0-40ed-4eeb-a100-03d3b7d228dd"}}}}, {"uuid": "9f385489-470c-4e4f-82ec-3e20b74fd3df", "name": "c396dca3-3bd5-4b66-8636-2b783f47eabc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3307696614484872, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.07740524652130432, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b108c76f-15e9-4990-af33-62b7addf308b", "name": "69701d81-85c2-43f5-be5e-bee3f7404249", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9f385489-470c-4e4f-82ec-3e20b74fd3df"}}}]}, {"uuid": "8382cc38-6044-45e3-9e0d-62ddfd873277", "name": "load_p1rlv822_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7ce197c-cee4-40df-b1d7-be13f1be8bb1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b108c76f-15e9-4990-af33-62b7addf308b"}}}}, {"uuid": "dd3e4e3a-3559-4027-afba-d627613059c6", "name": "21d52caf-ca54-492b-bc47-fa637a275d66_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3307696614484872, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.07740524652130432, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ba7bb2be-efad-4c03-8020-82c7b135863b", "name": "43163c38-efba-4c0e-9669-cef371ff9323", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dd3e4e3a-3559-4027-afba-d627613059c6"}}}]}, {"uuid": "1e56c001-43d9-4ef4-aa50-f82a1f42232d", "name": "load_p1rlv822_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7ce197c-cee4-40df-b1d7-be13f1be8bb1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ba7bb2be-efad-4c03-8020-82c7b135863b"}}}}, {"uuid": "43c1785d-9bed-4a42-877f-ad25a083d32e", "name": "de719e1f-e982-40a1-9d77-d4931c9ef1fe_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.396349422902612, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13402564403017767, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e5a93594-c464-46e5-94e3-ee0e9672a6f4", "name": "e81a1162-8c21-42ce-8159-51bf411564ae", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "43c1785d-9bed-4a42-877f-ad25a083d32e"}}}]}, {"uuid": "c6e5319e-9f6a-411c-af04-8f7bcbd5054c", "name": "load_p1rlv823_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81802469-7320-47e9-b826-fbb33bd371ab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e5a93594-c464-46e5-94e3-ee0e9672a6f4"}}}}, {"uuid": "732af354-3640-4143-8ab9-7f60cd75a7cb", "name": "67f449d4-29d0-41e9-926a-721a49b03abe_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.396349422902612, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13402564403017767, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e9e0b6ba-dd5c-4271-b788-e17debd0e9c1", "name": "99758b48-4b27-4629-9166-a329db484aa3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "732af354-3640-4143-8ab9-7f60cd75a7cb"}}}]}, {"uuid": "e28c0ad6-88fe-40ff-a288-8d5abdb44e54", "name": "load_p1rlv823_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81802469-7320-47e9-b826-fbb33bd371ab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e9e0b6ba-dd5c-4271-b788-e17debd0e9c1"}}}}, {"uuid": "ae0714a0-73be-4bae-8c83-bc9c9fa06ecf", "name": "6dcc93be-02a0-41ac-967f-e1079869c476_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2520868864654517, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.447133871274774, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7a24802e-526b-47a6-9ca6-2663b791840e", "name": "fd57d0f7-5105-4000-a96c-fa2643f11a48", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ae0714a0-73be-4bae-8c83-bc9c9fa06ecf"}}}]}, {"uuid": "7481a3f9-8384-48c9-9635-ee667876d70b", "name": "load_p1rlv824_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20ce76b6-9305-4525-b77e-b7300edc2c81"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7a24802e-526b-47a6-9ca6-2663b791840e"}}}}, {"uuid": "02a872db-8965-4030-be6c-e5eba07a0186", "name": "3bc89a2e-df99-411e-bfd7-7b60f6a0df53_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2520868864654517, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.447133871274774, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2d7c4db9-f57c-4683-9f7a-326a08a232cb", "name": "273da339-2e96-45f0-bf5a-361c5fabb759", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "02a872db-8965-4030-be6c-e5eba07a0186"}}}]}, {"uuid": "2da7ec48-a219-4860-b157-b952d788b1fd", "name": "load_p1rlv824_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20ce76b6-9305-4525-b77e-b7300edc2c81"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2d7c4db9-f57c-4683-9f7a-326a08a232cb"}}}}, {"uuid": "c25e60ea-748b-4dc8-91bd-11ba47a59b90", "name": "7705d927-687f-472f-9f3f-97f76e32d931_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.107858967059457, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3651352875232526, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ed082447-de8b-4db0-bcac-8321cd5b5865", "name": "dc510fb5-a27f-499e-aec2-85cfc57e665c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c25e60ea-748b-4dc8-91bd-11ba47a59b90"}}}]}, {"uuid": "1f09f953-cee0-45a4-a758-5408113a1b67", "name": "load_p1rlv825_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d209dff6-7a24-41ef-947a-8c6f79c2d65c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ed082447-de8b-4db0-bcac-8321cd5b5865"}}}}, {"uuid": "b148e492-bf6a-4644-97ab-97692805a008", "name": "4c356a34-1433-4277-8245-e8dd31188a15_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.107858967059457, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3651352875232526, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bd5e69ea-8e7b-4aa2-a197-465d10b3de6c", "name": "a23ea15f-02e5-4161-83df-0f68f951e1f5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b148e492-bf6a-4644-97ab-97692805a008"}}}]}, {"uuid": "2eae6474-5984-44cd-b557-74368e1ba0e5", "name": "load_p1rlv825_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d209dff6-7a24-41ef-947a-8c6f79c2d65c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bd5e69ea-8e7b-4aa2-a197-465d10b3de6c"}}}}, {"uuid": "6c33c342-8e5a-488a-b638-33e7ed70acb4", "name": "4d3811cd-4607-4ed9-b2a6-97940954c71a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.253869376169332, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.6228339639204339, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ce4c46dc-0f47-4985-bcbb-c278f75f57e5", "name": "820dcb99-deb3-45f7-8924-45da135769cc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c33c342-8e5a-488a-b638-33e7ed70acb4"}}}]}, {"uuid": "e1d6bb83-68ec-4e1c-8e31-96aaa50a140b", "name": "load_p1rlv826_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06746d4d-3db8-45b1-888e-d3d9e405ccaf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ce4c46dc-0f47-4985-bcbb-c278f75f57e5"}}}}, {"uuid": "a561e955-6cdb-4877-92b3-76a511ec69dd", "name": "6907b347-f27e-4119-81ce-258996b075ab_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.253869376169332, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.6228339639204339, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4d9d58e4-826f-4533-976a-07a74519c72c", "name": "5336a82c-6365-4ec0-808d-6e5f1c778f25", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a561e955-6cdb-4877-92b3-76a511ec69dd"}}}]}, {"uuid": "57fb6b3f-38b0-4c6b-896e-e458a17c2e13", "name": "load_p1rlv826_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06746d4d-3db8-45b1-888e-d3d9e405ccaf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4d9d58e4-826f-4533-976a-07a74519c72c"}}}}, {"uuid": "59863883-9c7c-4105-aad3-649bc7f1c86c", "name": "42a04cbe-98b1-4573-bbdb-a4ed8fefdb84_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7037919474579788, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6943112548118018, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a0da3511-7362-46bb-ad2b-e10a83884207", "name": "ba8319d8-b6c4-4d55-8ecd-2d7863eaa07c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "59863883-9c7c-4105-aad3-649bc7f1c86c"}}}]}, {"uuid": "97e3d9fc-8e5e-4414-b212-0538210a1add", "name": "load_p1rlv827_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c89db91-40fe-4de6-973e-5d8c23e35080"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a0da3511-7362-46bb-ad2b-e10a83884207"}}}}, {"uuid": "983a7419-bc91-4c68-9e29-fbe68f06fe48", "name": "1f6e40aa-31bc-4190-91b8-d783c587d4fe_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7037919474579788, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6943112548118018, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a361842b-d762-4198-ade6-c746a872ea4f", "name": "30b629ce-6a69-4159-996f-c797e585ae37", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "983a7419-bc91-4c68-9e29-fbe68f06fe48"}}}]}, {"uuid": "06acf64c-354f-444c-bf0c-99db6ed05d02", "name": "load_p1rlv827_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c89db91-40fe-4de6-973e-5d8c23e35080"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a361842b-d762-4198-ade6-c746a872ea4f"}}}}, {"uuid": "c0da35c7-38c3-4a5f-b49c-fd926354dc45", "name": "629fac6e-d544-4445-869f-cd6d0ef5e52c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8668291909105112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7572719732007044, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7fd263c3-70d0-417c-9a9f-204208d60db4", "name": "40370cd1-6e63-4ebf-a139-9431d9e4f6a0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c0da35c7-38c3-4a5f-b49c-fd926354dc45"}}}]}, {"uuid": "0667d89d-8655-4719-910e-b5c90e028e24", "name": "load_p1rlv828_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08c3f5ef-c2d5-4ce2-8fc7-b665d8cbbab6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7fd263c3-70d0-417c-9a9f-204208d60db4"}}}}, {"uuid": "cc6c55e1-5bfe-48df-8608-a17fa1321933", "name": "3959c432-385d-4a8d-89c9-41cd743eb8ca_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8668291909105112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7572719732007044, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "214e9093-d512-4c67-bf8a-ef70b8086f41", "name": "cbd2b3d4-fd43-4096-8e91-63b2907967d8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cc6c55e1-5bfe-48df-8608-a17fa1321933"}}}]}, {"uuid": "ea5bcc31-c953-4505-8c46-60511b2f876e", "name": "load_p1rlv828_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08c3f5ef-c2d5-4ce2-8fc7-b665d8cbbab6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "214e9093-d512-4c67-bf8a-ef70b8086f41"}}}}, {"uuid": "7ad6bc0c-b62f-44ae-9c37-ab3b4052d7c8", "name": "f30d3093-c727-47e3-baba-93875c057f3e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7400090938863744, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.257745187793523, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "401a8519-192c-42da-a41a-bdad27ed8419", "name": "0aa20863-91fe-49fe-a3ed-41231982e601", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7ad6bc0c-b62f-44ae-9c37-ab3b4052d7c8"}}}]}, {"uuid": "0ff83211-0502-4e70-a369-18a16f4ae90c", "name": "load_p1rlv829_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e3a1bd0-69fe-42bb-993d-2094ecc658ce"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "401a8519-192c-42da-a41a-bdad27ed8419"}}}}, {"uuid": "a4bf3895-2bb5-4ee3-8cfe-2e09c907fd8c", "name": "e6fa068a-bf15-4d7d-8332-e191453e2acd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7400090938863744, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.257745187793523, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eb8fdc59-30ac-483d-9df4-0dec6bb85ceb", "name": "7740e9e8-162d-4b41-8c1a-212cea502eb9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a4bf3895-2bb5-4ee3-8cfe-2e09c907fd8c"}}}]}, {"uuid": "299e04bb-1d60-423e-8d18-56645cf724fc", "name": "load_p1rlv829_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e3a1bd0-69fe-42bb-993d-2094ecc658ce"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eb8fdc59-30ac-483d-9df4-0dec6bb85ceb"}}}}, {"uuid": "91821f0d-42c1-443d-bab5-f4dbfa137736", "name": "6d6ba518-b330-41aa-8db4-9eee5d01dcf6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9541125560071345, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3732603805546264, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9608867c-46ad-4f6e-bad2-a4ebf473085b", "name": "03eaea5d-cfcd-4011-9944-96a383b5746f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "91821f0d-42c1-443d-bab5-f4dbfa137736"}}}]}, {"uuid": "b9160f40-3f3a-4063-b2c5-28972fb67dcc", "name": "load_p1rlv830_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b7538477-32ab-4db6-872d-83be7ec89fd9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9608867c-46ad-4f6e-bad2-a4ebf473085b"}}}}, {"uuid": "faae66b1-94b7-4b3f-a513-844e1d4e3b59", "name": "d939b1ac-1f94-4ebf-833e-d6c7748a8701_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9541125560071345, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3732603805546264, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "22ba8929-046b-4dda-a245-91697081fac6", "name": "b88128e3-e68d-4911-a40b-e6b57028509d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "faae66b1-94b7-4b3f-a513-844e1d4e3b59"}}}]}, {"uuid": "c080c3d3-8276-4554-85db-b92e863ffa05", "name": "load_p1rlv830_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b7538477-32ab-4db6-872d-83be7ec89fd9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "22ba8929-046b-4dda-a245-91697081fac6"}}}}, {"uuid": "610b56f9-d801-45ae-91db-df6cf2d35a48", "name": "853c8726-a620-4d7a-90e1-56e680eb8707_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.746284303820433, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6724067157838972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5ef1cd69-1981-4100-ae90-f109a7a00c4e", "name": "e3db4086-7eaf-4569-aff4-b6855d4845ff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "610b56f9-d801-45ae-91db-df6cf2d35a48"}}}]}, {"uuid": "717c1f69-4334-47b0-9273-fe51d52e1411", "name": "load_p1rlv831_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4b6c4e-78d0-4c8e-907c-619f1e43c149"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5ef1cd69-1981-4100-ae90-f109a7a00c4e"}}}}, {"uuid": "67766f61-4a1d-4ae4-949d-345e1fa00a3b", "name": "f577a9b9-c12a-4073-8d3b-edfaeceec0a7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.746284303820433, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6724067157838972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b309dd9b-3303-4986-bf5d-7b6a9125fbfa", "name": "30b217c3-5083-4f0f-83d1-5a83ff59cdec", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "67766f61-4a1d-4ae4-949d-345e1fa00a3b"}}}]}, {"uuid": "a9025d91-ecf5-40e7-a428-35f87c18338b", "name": "load_p1rlv831_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4b6c4e-78d0-4c8e-907c-619f1e43c149"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b309dd9b-3303-4986-bf5d-7b6a9125fbfa"}}}}, {"uuid": "afc3c4de-ab14-43a4-8d9e-9707108c6cb5", "name": "6bee1ada-96fe-4d3d-81f5-c1d0a73bad25_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.250267265771566, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8009319586825154, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ac573839-6e5c-4f36-9a7b-539fa20cd575", "name": "d8c6d513-2c81-4cfe-a307-6e39d448e951", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "afc3c4de-ab14-43a4-8d9e-9707108c6cb5"}}}]}, {"uuid": "0b4ab97a-46d5-4222-be17-9a01904cb32e", "name": "load_p1rlv832_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10373c0d-6a3c-4160-a174-22de447d4c38"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ac573839-6e5c-4f36-9a7b-539fa20cd575"}}}}, {"uuid": "7229411d-e4f1-4f2b-99a0-e7ba1ae18b31", "name": "35c3f57a-bf1f-413d-ad43-41a74ca34e27_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.250267265771566, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8009319586825154, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8b0cd29d-184f-4521-ad39-ea089bf07926", "name": "24c33887-3572-4423-9d5b-cdf7de2cbe5b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7229411d-e4f1-4f2b-99a0-e7ba1ae18b31"}}}]}, {"uuid": "7ba46c6f-ba1c-47d7-9b7a-06e1e5719ae1", "name": "load_p1rlv832_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10373c0d-6a3c-4160-a174-22de447d4c38"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8b0cd29d-184f-4521-ad39-ea089bf07926"}}}}, {"uuid": "9e1344e8-665f-4802-bc78-adc16aec041a", "name": "2bccc6c8-546c-4581-b75f-badf5b5cb7d4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1212324580541053, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5100712782164012, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2651276c-e3e2-4864-afc8-1da4343802b9", "name": "f3efb4cd-794e-4529-9c3c-341c54217828", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9e1344e8-665f-4802-bc78-adc16aec041a"}}}]}, {"uuid": "21b607ba-0654-4239-be2d-fadce2328dd7", "name": "load_p1rlv833_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eb57fc4-636d-4923-9f4a-d308b062599f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2651276c-e3e2-4864-afc8-1da4343802b9"}}}}, {"uuid": "f12af18a-47fa-47d1-a761-95ec62686d35", "name": "9886c5ae-49a6-4fa0-b833-409938e3701e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1212324580541053, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5100712782164012, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "49bcbe3a-fe71-406c-a18b-38410946c071", "name": "624ef648-caab-4363-9633-a4af7656fbae", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f12af18a-47fa-47d1-a761-95ec62686d35"}}}]}, {"uuid": "3dfe3a27-efa3-4260-a84f-c3af41c6c947", "name": "load_p1rlv833_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eb57fc4-636d-4923-9f4a-d308b062599f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "49bcbe3a-fe71-406c-a18b-38410946c071"}}}}, {"uuid": "828de88b-2da7-4949-a09d-a7e48e037427", "name": "fe52519e-3b08-4cdc-8dff-5c6c8dea6a26_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.107858967059457, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3651352875232526, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f2fbfcd4-8d69-47a6-af51-318cfac95969", "name": "1c968931-2b64-4deb-8271-85610cbaf286", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "828de88b-2da7-4949-a09d-a7e48e037427"}}}]}, {"uuid": "0d46b9b6-70f9-43ca-8440-b4e9bad211fa", "name": "load_p1rlv834_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d437c83c-cbd1-41bf-b455-21123e82d59f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f2fbfcd4-8d69-47a6-af51-318cfac95969"}}}}, {"uuid": "15c45dba-5e69-4c70-b57e-2ee55683f89b", "name": "bce8a9a9-d325-4088-bed5-f1e9efafb067_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.107858967059457, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3651352875232526, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b25d3f8b-b0bc-49a0-bbc9-2b0517ac3c39", "name": "04c293e5-c570-4ee9-be1c-98e3b93fcdd0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "15c45dba-5e69-4c70-b57e-2ee55683f89b"}}}]}, {"uuid": "56510e77-31ae-4502-8883-767e359af33c", "name": "load_p1rlv834_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d437c83c-cbd1-41bf-b455-21123e82d59f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b25d3f8b-b0bc-49a0-bbc9-2b0517ac3c39"}}}}, {"uuid": "308e0b97-6215-4e63-aecc-72d5a156ebd0", "name": "b591c622-741a-4b41-966e-7b0e3ac368f4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1426015471760884, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5928311844731246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "646a7475-4643-4898-805a-75f320668a09", "name": "7680aef7-bdbe-4eed-89a3-72d8d86ee122", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "308e0b97-6215-4e63-aecc-72d5a156ebd0"}}}]}, {"uuid": "f54d8273-6c0f-48c5-9266-581a386820c2", "name": "load_p1rlv835_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bc35476-5839-4095-bea5-36e32450b890"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "646a7475-4643-4898-805a-75f320668a09"}}}}, {"uuid": "a9b9efc3-5b10-4a82-ae2f-6772a746aa4d", "name": "7c4c87bf-59d0-4f19-a53d-841f529cb164_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1426015471760884, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5928311844731246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "657e4375-2b1e-420b-8447-a12cd7246c24", "name": "e6529a33-34f4-4c52-920d-4fbf92b78d5d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a9b9efc3-5b10-4a82-ae2f-6772a746aa4d"}}}]}, {"uuid": "8858b368-17f9-43a7-895a-67d5d3a09b35", "name": "load_p1rlv835_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bc35476-5839-4095-bea5-36e32450b890"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "657e4375-2b1e-420b-8447-a12cd7246c24"}}}}, {"uuid": "6b543206-afcc-4053-af5a-60eae057d2dd", "name": "9f53b4f5-d81a-4842-bb37-dab765efb4a0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.941898785419248, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8498359578625553, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "17c99f84-2e3f-4355-afd0-0e5d869deccb", "name": "9bd960e5-1579-4c69-a241-2c964d985a09", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6b543206-afcc-4053-af5a-60eae057d2dd"}}}]}, {"uuid": "625a15f2-f4b1-4664-becf-522994dfcc67", "name": "load_p1rlv836_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12556ab7-c50a-4624-9d84-b85585822245"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "17c99f84-2e3f-4355-afd0-0e5d869deccb"}}}}, {"uuid": "18b48cec-54f1-4030-8722-dc2c86f02589", "name": "bb4b9f21-c379-4328-9541-8879c5c3f1e8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.941898785419248, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8498359578625553, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5f7fb70e-fa24-40c4-b113-ee644f4111bd", "name": "424ea7c6-2b33-4b83-88f3-23b0ef04e6d9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "18b48cec-54f1-4030-8722-dc2c86f02589"}}}]}, {"uuid": "b434d51d-ba3f-4122-87f2-6ff564f6efdc", "name": "load_p1rlv836_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12556ab7-c50a-4624-9d84-b85585822245"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5f7fb70e-fa24-40c4-b113-ee644f4111bd"}}}}, {"uuid": "15ca6d0b-f87e-47b7-9e40-dab53f7172ed", "name": "745a9d60-cfb1-4af2-b253-0383da07e4e7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4663769608466568, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5502546109327153, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e1a94eab-8ce7-4787-b6c2-86c56ef4334e", "name": "48636bca-59fb-48b8-bdf7-303c97e0d622", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "15ca6d0b-f87e-47b7-9e40-dab53f7172ed"}}}]}, {"uuid": "8c7dd958-fab7-4776-90a0-0cc111dc9d1e", "name": "load_p1rlv837_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33492e0f-c907-46c6-a529-503480b642bb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e1a94eab-8ce7-4787-b6c2-86c56ef4334e"}}}}, {"uuid": "c813fd7f-5cc8-44e7-b411-b841482231f8", "name": "d0cf8302-c91b-43e5-90ed-f81efb1848d5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4663769608466568, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5502546109327153, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d004d951-a13f-4dfc-bbf9-e685e2ba6ccb", "name": "5659efd3-414f-444b-aaa0-0aa0e9454b67", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c813fd7f-5cc8-44e7-b411-b841482231f8"}}}]}, {"uuid": "5744bba1-a670-436a-b29c-c45ce46cfe5c", "name": "load_p1rlv837_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33492e0f-c907-46c6-a529-503480b642bb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d004d951-a13f-4dfc-bbf9-e685e2ba6ccb"}}}}, {"uuid": "e59167f2-ae8c-484a-aed5-6e7518c1e6b6", "name": "f76b109d-e72b-427d-a9aa-b13a297e3018_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3464174292990054, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8802812503815668, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "62c8c8bb-5f9f-42fe-9919-7742b22a5265", "name": "c92d20d8-9859-482f-82c6-033771a0b76b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e59167f2-ae8c-484a-aed5-6e7518c1e6b6"}}}]}, {"uuid": "20ab6f62-5c4e-4508-90ad-6fe1a71ab34a", "name": "load_p1rlv838_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7ffe87d-4424-4495-83c1-6765d385207c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "62c8c8bb-5f9f-42fe-9919-7742b22a5265"}}}}, {"uuid": "c82016b9-e40e-4e2a-b866-4c0541f9db78", "name": "adeda6f9-bfa2-4159-8b66-912227216c35_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3464174292990054, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8802812503815668, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ff51bfab-4d8d-4e23-9397-b7eb2553ca6e", "name": "e31a30f3-80b5-43ae-b498-a38eb7e2f8db", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c82016b9-e40e-4e2a-b866-4c0541f9db78"}}}]}, {"uuid": "a0507800-213a-4e03-b02b-72090c6c2e93", "name": "load_p1rlv838_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7ffe87d-4424-4495-83c1-6765d385207c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ff51bfab-4d8d-4e23-9397-b7eb2553ca6e"}}}}, {"uuid": "8791ab4c-c618-4962-a1ef-ae457fefd9f1", "name": "b7168462-c24d-43bb-b983-55d3b9b9c877_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3086582709384027, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12628327836733033, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0d61d9c4-026e-44a3-9fc9-57e3a534a981", "name": "8b80649c-86e8-4ea2-9fc4-c25a8da3d6ae", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8791ab4c-c618-4962-a1ef-ae457fefd9f1"}}}]}, {"uuid": "5c2fe452-6368-42d8-b1f6-801d4285f1e9", "name": "load_p1rlv839_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48e97be9-1f80-457f-a56e-79f54458c620"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0d61d9c4-026e-44a3-9fc9-57e3a534a981"}}}}, {"uuid": "e9891289-6645-40d0-b3f4-3fe938d4bf4f", "name": "a9c3ba8d-6e50-4b4b-b2ee-49b081413bb5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3086582709384027, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12628327836733033, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "709a13e8-7896-411c-8060-b8656b4b1b2d", "name": "079e76c7-3459-47d4-b774-90bfc1ec9ccd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e9891289-6645-40d0-b3f4-3fe938d4bf4f"}}}]}, {"uuid": "2a329d21-97c6-47ac-a98c-2406bd17b0cc", "name": "load_p1rlv839_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48e97be9-1f80-457f-a56e-79f54458c620"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "709a13e8-7896-411c-8060-b8656b4b1b2d"}}}}, {"uuid": "01bc638c-a479-4e7d-805a-d7137f576946", "name": "eafe6c48-c593-468e-880b-d8c42d7e1e87_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4950137537296666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31506625700854357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "de546a87-f52b-4343-b6d8-ee5fdc026203", "name": "d42df018-de45-407f-9f08-2f702c2f0468", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "01bc638c-a479-4e7d-805a-d7137f576946"}}}]}, {"uuid": "990c975d-7dac-4138-ae0e-698b5d9d1b39", "name": "load_p1rlv840_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "024961c3-25f4-4a15-a52a-7f88dc652766"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "de546a87-f52b-4343-b6d8-ee5fdc026203"}}}}, {"uuid": "ec04d3e5-797c-48a5-8ab7-57dd0a77a3c9", "name": "9f29c20c-d852-4c24-877d-0bbb7058be6c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4950137537296666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31506625700854357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f42e8ec-3919-43ad-9346-b9ee5da3f499", "name": "4332240a-aa4d-464f-88a9-7b0f4ae0b295", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ec04d3e5-797c-48a5-8ab7-57dd0a77a3c9"}}}]}, {"uuid": "ab9f5e05-2970-4924-8a85-aae4fe263b3e", "name": "load_p1rlv840_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "024961c3-25f4-4a15-a52a-7f88dc652766"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f42e8ec-3919-43ad-9346-b9ee5da3f499"}}}}, {"uuid": "9785cfe5-256a-486d-a324-1bd5f30a5e19", "name": "1702e774-78fc-4206-b45b-14bb4f2aa4ba_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9614713621548963, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.170985110067395, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "475962a7-6780-4135-86e3-009d5d683a6b", "name": "7ca65b02-a7da-434d-9c31-f495b72c312c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9785cfe5-256a-486d-a324-1bd5f30a5e19"}}}]}, {"uuid": "cfa6d704-c332-44d1-ba2e-31172bba49da", "name": "load_p1rlv841_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eb6c1b4-f09a-44a5-a13f-64051183736d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "475962a7-6780-4135-86e3-009d5d683a6b"}}}}, {"uuid": "8f3aa178-a4a2-4884-b53f-a8f2409614ba", "name": "16a86396-039a-474c-aa5f-a2e098358315_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9614713621548963, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.170985110067395, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "04943b34-4a8a-422e-aef7-d4470dc9b981", "name": "2c38238e-59a3-4fd1-93ff-671ebc712e95", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8f3aa178-a4a2-4884-b53f-a8f2409614ba"}}}]}, {"uuid": "e7720fb8-1f33-4c47-be4b-88e5a430b611", "name": "load_p1rlv841_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eb6c1b4-f09a-44a5-a13f-64051183736d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "04943b34-4a8a-422e-aef7-d4470dc9b981"}}}}, {"uuid": "b7af79f8-1862-46b0-b51f-0c825baf15d9", "name": "64556f90-f1e4-4e44-a053-a9d536fb1e79_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8285317723273034, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9836303634928509, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "48ca5f56-bf1f-45f8-b8bb-9b040ded4573", "name": "0b6cf306-da1f-4286-a5a2-521ba012fd54", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b7af79f8-1862-46b0-b51f-0c825baf15d9"}}}]}, {"uuid": "0940874a-e752-42c9-90ae-e7be990bb853", "name": "load_p1rlv842_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8f304a4-6e39-4288-9b9b-e41bb37c6019"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "48ca5f56-bf1f-45f8-b8bb-9b040ded4573"}}}}, {"uuid": "627dcd89-b96d-4c13-8abd-b98c9111fd73", "name": "df20d7e6-68c2-4695-b4f1-fa4ca288c8dc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8285317723273034, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9836303634928509, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8ba1a638-dfb0-4e1d-b530-78df11b9d5f1", "name": "cb3c7422-da41-45c7-9a9d-993d5a4a6897", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "627dcd89-b96d-4c13-8abd-b98c9111fd73"}}}]}, {"uuid": "cb3eaf0a-c353-43bc-94b1-764ed209ad42", "name": "load_p1rlv842_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8f304a4-6e39-4288-9b9b-e41bb37c6019"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8ba1a638-dfb0-4e1d-b530-78df11b9d5f1"}}}}, {"uuid": "9829bdca-2176-4d31-8c70-d08643ab2027", "name": "59648600-ec8c-4903-afae-2622087f494a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7943609059660943, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8824322096654456, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b701fec3-1eb1-4beb-b725-fb95c0b2c7c7", "name": "86103c0d-dcad-49b9-aa08-f4b555bae597", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9829bdca-2176-4d31-8c70-d08643ab2027"}}}]}, {"uuid": "13454edd-3943-4d68-9ce7-b08db819335a", "name": "load_p1rlv843_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3bc013f-c78d-4a3c-b27f-826c3025de0e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b701fec3-1eb1-4beb-b725-fb95c0b2c7c7"}}}}, {"uuid": "36e9cb2d-c336-43c7-958f-597584a7b4d6", "name": "ce8e56f3-a73d-41f0-97db-1f768e25f537_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7943609059660943, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8824322096654456, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c4a7ab30-c1ad-4ce7-97b2-2604f23ea4f3", "name": "6a5bd58b-6aba-407c-9d12-4cc182b603fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "36e9cb2d-c336-43c7-958f-597584a7b4d6"}}}]}, {"uuid": "eb0a4e99-8354-47ec-a036-a49ce41f9bcc", "name": "load_p1rlv843_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3bc013f-c78d-4a3c-b27f-826c3025de0e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c4a7ab30-c1ad-4ce7-97b2-2604f23ea4f3"}}}}, {"uuid": "ffa75d2e-5c98-4afa-b23b-f70dd0be73a3", "name": "ed64f055-1c53-4159-a244-06b2e908e817_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.062987656442733, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.2699236524876967, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ca2f73cf-b69b-4011-ab51-ca490b35fd76", "name": "3facab19-f51f-47e3-b137-1a3803f920ee", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ffa75d2e-5c98-4afa-b23b-f70dd0be73a3"}}}]}, {"uuid": "946b5b25-8afa-4bde-9b2a-c736d884eec9", "name": "load_p1rlv844_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26294827-db76-40b6-b652-1e41efdf15dc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ca2f73cf-b69b-4011-ab51-ca490b35fd76"}}}}, {"uuid": "c6f6f984-64c4-4396-89fd-c9c47042fc28", "name": "b62398c0-d470-441b-a912-a47fced3a655_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.062987656442733, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.2699236524876967, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "28fc005b-75dd-46c7-b9db-d5e8c6127aa1", "name": "772310ab-cafb-49ea-8f32-60a74196f0f6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c6f6f984-64c4-4396-89fd-c9c47042fc28"}}}]}, {"uuid": "a7e0dcd0-a7c6-4adb-b88f-f492af62b272", "name": "load_p1rlv844_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26294827-db76-40b6-b652-1e41efdf15dc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "28fc005b-75dd-46c7-b9db-d5e8c6127aa1"}}}}, {"uuid": "b4003b35-2b3b-4af0-8de4-604977581c97", "name": "8cb5ff7f-5aef-42bf-9119-a05dad52b9f9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.910200682298975, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5555412020426419, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ab226e6d-82fd-41e8-b993-5b84b51eb4ff", "name": "39b0862f-feb7-4da5-885d-73d78e073189", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b4003b35-2b3b-4af0-8de4-604977581c97"}}}]}, {"uuid": "8376fc1a-b59f-43cb-a5a8-44d0b44d29ab", "name": "load_p1rlv845_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b053d449-b15b-4292-9a73-9b7d104a8e38"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ab226e6d-82fd-41e8-b993-5b84b51eb4ff"}}}}, {"uuid": "c3958938-cbd3-472a-9c99-95806bb84b3f", "name": "f59a083b-e6d9-4685-aeb1-0cf60622c86e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.910200682298975, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5555412020426419, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "00461c76-6c87-4612-bc51-1d0989527a7b", "name": "0c09ca8e-8769-4600-a588-90eca8873146", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c3958938-cbd3-472a-9c99-95806bb84b3f"}}}]}, {"uuid": "d0b71404-56b4-4fe4-ab8d-b5cf552f66b9", "name": "load_p1rlv845_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b053d449-b15b-4292-9a73-9b7d104a8e38"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "00461c76-6c87-4612-bc51-1d0989527a7b"}}}}, {"uuid": "a55e9cf6-429f-4c71-87de-16ec31853880", "name": "a262e4df-1fef-433b-9ab9-abd8ae469f43_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.772705532239135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.33568286747913667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fa5a99e8-9d11-4954-acc6-47fc1451bbac", "name": "4fcfc64d-9655-48a4-9536-f39ed0b9f374", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a55e9cf6-429f-4c71-87de-16ec31853880"}}}]}, {"uuid": "638ffa96-1e7e-4d99-8bee-907f52cbcc88", "name": "load_p1rlv846_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "145d3757-ca09-45ca-9199-465b6b43fbb7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fa5a99e8-9d11-4954-acc6-47fc1451bbac"}}}}, {"uuid": "2929e2ac-0e30-46eb-b71b-5364e978fe8d", "name": "8365ebed-ff8a-4203-a100-4913109d1bdd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.772705532239135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.33568286747913667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fb5a7159-cbc6-49b0-b1cb-ebcc1dec4b1a", "name": "f5d2c0ae-6b91-4a0b-8817-e22c4ba36710", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2929e2ac-0e30-46eb-b71b-5364e978fe8d"}}}]}, {"uuid": "fec9c5f7-9aa9-48ac-92b1-e3d93fee3c65", "name": "load_p1rlv846_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "145d3757-ca09-45ca-9199-465b6b43fbb7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fb5a7159-cbc6-49b0-b1cb-ebcc1dec4b1a"}}}}, {"uuid": "fa3f6062-4671-4203-8049-c4fad65a9237", "name": "5ecc8f7c-532c-4803-93d5-a8b2ff8bf3aa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2075389461119934, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3167249782629938, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "33d3cde7-a420-435c-8b91-31dfe50c2860", "name": "50247295-4690-4540-bb6a-ccbbdb6d5bf7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fa3f6062-4671-4203-8049-c4fad65a9237"}}}]}, {"uuid": "9c473154-b8b2-4064-9a6a-89dc5a54b69f", "name": "load_p1rlv847_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "283142ff-4884-4adc-9d4c-f8615505415a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "33d3cde7-a420-435c-8b91-31dfe50c2860"}}}}, {"uuid": "c9fc333b-5a54-4b28-a6d4-cd6ccdfe2b6b", "name": "53b25bbb-72d0-4a3d-86a3-0fa55219cfd3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2075389461119934, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3167249782629938, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "969e7e4a-dd5b-46ae-b883-2eb2b40f848b", "name": "e35fb445-415a-4951-853a-47d951f12a41", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9fc333b-5a54-4b28-a6d4-cd6ccdfe2b6b"}}}]}, {"uuid": "14a2504d-01b8-4aac-8748-b0376320ab33", "name": "load_p1rlv847_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "283142ff-4884-4adc-9d4c-f8615505415a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "969e7e4a-dd5b-46ae-b883-2eb2b40f848b"}}}}, {"uuid": "c09d2a7a-d38b-4a5f-86b4-9aea3f3f91b7", "name": "cb6907ad-7410-4473-b3f4-3da1ba202a27_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4794755457968312, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.46197673612457824, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6d3e07b4-1a35-48c9-8adc-6f52113102d6", "name": "e8755510-0e03-4a73-9cce-6b4a79f27838", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c09d2a7a-d38b-4a5f-86b4-9aea3f3f91b7"}}}]}, {"uuid": "4ebbbbb3-7e08-4715-aceb-51a122998f2f", "name": "load_p1rlv848_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e484d77-29ac-4903-afa3-f677283db883"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6d3e07b4-1a35-48c9-8adc-6f52113102d6"}}}}, {"uuid": "51a4e04c-711d-4bd6-8316-c648e2b89856", "name": "6235b454-706d-49e7-ac71-a9344113b912_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4794755457968312, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.46197673612457824, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fd740f4a-7f4c-4795-9bd3-939ec892f916", "name": "d30fa4e9-56e8-4d00-8ca9-0f242173d56f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "51a4e04c-711d-4bd6-8316-c648e2b89856"}}}]}, {"uuid": "5a98bb20-7c07-4b1b-bd7b-d5c289466cf2", "name": "load_p1rlv848_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e484d77-29ac-4903-afa3-f677283db883"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fd740f4a-7f4c-4795-9bd3-939ec892f916"}}}}, {"uuid": "8cab14d9-0a0f-40bf-9b68-d1e2e46939f8", "name": "fd72b7b0-105f-4add-bbd1-d9df40e05337_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.292799122473319, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5385753507809203, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cf07e1f2-31e7-488d-bdb8-479391d57add", "name": "c9581250-75c5-46bd-bb58-d7a7bbd303f7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8cab14d9-0a0f-40bf-9b68-d1e2e46939f8"}}}]}, {"uuid": "4472bb76-70f3-44ff-9d15-46518c7d0d04", "name": "load_p1rlv849_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a95877ca-8600-4e95-82ac-c51cb82acf16"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cf07e1f2-31e7-488d-bdb8-479391d57add"}}}}, {"uuid": "da281240-6876-4756-b99e-99707b3e4b53", "name": "b446a498-18f1-40f2-b50d-fe77f39b60b8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.292799122473319, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5385753507809203, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7e6c224f-9f73-450b-9560-75283650ef2c", "name": "98426f92-904d-4b94-b1e0-99d6c346f267", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "da281240-6876-4756-b99e-99707b3e4b53"}}}]}, {"uuid": "a388bf38-0fb8-4c4b-8736-53457df89b59", "name": "load_p1rlv849_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a95877ca-8600-4e95-82ac-c51cb82acf16"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7e6c224f-9f73-450b-9560-75283650ef2c"}}}}, {"uuid": "079e87a7-2dcf-4c41-82c1-d355db6fd5b7", "name": "da6e5544-3742-4ded-9307-e762416cee5e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.737986692242784, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8906640815201406, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b71072af-4d15-4d1d-bfc9-3edcda196026", "name": "e94dd721-a476-469d-a978-b2f77a3e172c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "079e87a7-2dcf-4c41-82c1-d355db6fd5b7"}}}]}, {"uuid": "b4ac23ec-155a-40fd-85f4-77c43c345631", "name": "load_p1rlv850_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d49057-9c70-4489-95bb-36b5b574e13d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b71072af-4d15-4d1d-bfc9-3edcda196026"}}}}, {"uuid": "c95ac71a-681f-4509-9eba-895a289012d8", "name": "e333efe5-158e-43aa-bdac-155844fbd620_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.737986692242784, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8906640815201406, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "87ddf4da-1542-4022-ad08-cf51913dcf99", "name": "178dc8e1-2375-4a0d-b439-b31c05197025", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c95ac71a-681f-4509-9eba-895a289012d8"}}}]}, {"uuid": "ae73fe56-081e-4996-9bff-d4b073c8dd98", "name": "load_p1rlv850_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d49057-9c70-4489-95bb-36b5b574e13d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "87ddf4da-1542-4022-ad08-cf51913dcf99"}}}}, {"uuid": "938176d6-c264-46f9-b916-44fa987b069a", "name": "2d46fa4e-175e-4ec6-b74d-5dfa3815b18e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6295328634326751, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9988748196040309, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f74787d6-5835-45fa-9290-422bed794f4d", "name": "fa19786d-68d6-4c6a-a062-9235f7c8dfee", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "938176d6-c264-46f9-b916-44fa987b069a"}}}]}, {"uuid": "8a15f266-4f98-4288-8ba5-263a877aeb48", "name": "load_p1rlv851_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48b5535c-f00d-4b48-a23a-87f3f212302f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f74787d6-5835-45fa-9290-422bed794f4d"}}}}, {"uuid": "6b120a3a-f663-4d9f-a57c-ddfd8f2dec4b", "name": "ca2a0e01-00ff-4ef4-aaa5-8aae694aea9f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6295328634326751, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9988748196040309, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fb9087aa-1791-47a4-adeb-a6547ac17b6c", "name": "31097e7a-9eec-4dfa-9a62-3b613bf8bf26", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6b120a3a-f663-4d9f-a57c-ddfd8f2dec4b"}}}]}, {"uuid": "ac397b0f-76ec-4e36-b6c8-415905f2bb6f", "name": "load_p1rlv851_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48b5535c-f00d-4b48-a23a-87f3f212302f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fb9087aa-1791-47a4-adeb-a6547ac17b6c"}}}}, {"uuid": "c2a1f7b5-19ab-47aa-937f-05f52627dddc", "name": "659a36bd-a7aa-4dec-9acf-d31fbb16260a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.072248840478098, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4856137999354615, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f9ad31eb-3ffb-4797-a746-b1604ab4f2b7", "name": "2bdc508a-656f-4100-861f-98a999f72776", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c2a1f7b5-19ab-47aa-937f-05f52627dddc"}}}]}, {"uuid": "32ef83b5-8cc7-4a68-93b8-41764a6abcaa", "name": "load_p1rlv852_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32142941-c546-4356-ba80-123b9128b5de"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f9ad31eb-3ffb-4797-a746-b1604ab4f2b7"}}}}, {"uuid": "86075a23-c51e-49ba-af91-77ff46df6dd3", "name": "01103004-1ff0-4f2c-99f8-3cc408fc55a0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.072248840478098, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4856137999354615, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c6d823a9-35a7-45f1-b243-e78bf6fe23b5", "name": "36396a64-3c5d-4b86-945a-0b3d3cd6d5db", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "86075a23-c51e-49ba-af91-77ff46df6dd3"}}}]}, {"uuid": "ae20b46b-5e41-4a03-9a59-55b7522c841d", "name": "load_p1rlv852_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32142941-c546-4356-ba80-123b9128b5de"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c6d823a9-35a7-45f1-b243-e78bf6fe23b5"}}}}, {"uuid": "96605a2b-6efd-43aa-8a81-f5fc0dba3f0e", "name": "deaf567c-a026-4554-a0a7-687792ab63e9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0307394237991176, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0095205649117913, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "123eebfc-2042-4715-ab91-25732d479e72", "name": "c4872abd-c3bc-4209-8802-bc99fe0f02c3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "96605a2b-6efd-43aa-8a81-f5fc0dba3f0e"}}}]}, {"uuid": "0f13dd75-128f-4674-8647-5b56add5b599", "name": "load_p1rlv853_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "365eff25-8ccb-448b-894f-ad662fe6d684"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "123eebfc-2042-4715-ab91-25732d479e72"}}}}, {"uuid": "8facf6cb-c11b-4172-92b8-83e781a3b8f1", "name": "7cd73183-8983-48c8-b26e-296f3dbe8117_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0307394237991176, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0095205649117913, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "95f41b66-dea3-421b-8f9a-154274c833cf", "name": "9e2d777a-b466-42de-837a-34372aee43f6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8facf6cb-c11b-4172-92b8-83e781a3b8f1"}}}]}, {"uuid": "758828f8-84b9-4627-aa37-55b2e0484323", "name": "load_p1rlv853_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "365eff25-8ccb-448b-894f-ad662fe6d684"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "95f41b66-dea3-421b-8f9a-154274c833cf"}}}}, {"uuid": "717840ac-6dd6-4827-bd43-a554fb72da8c", "name": "d0ee04c6-6faf-4755-9ffa-0969c8e06caf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.621947646480353, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0332384495271123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "64472809-31e9-4821-a8a2-607cb1c44575", "name": "aaa6b3c4-c3d3-457f-b6a7-c3ab9f5eb44e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "717840ac-6dd6-4827-bd43-a554fb72da8c"}}}]}, {"uuid": "9bb9e900-0cbe-480f-b913-d84926db0a02", "name": "load_p1rlv854_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2461b6f0-9a40-4b6f-9669-be479da039f3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "64472809-31e9-4821-a8a2-607cb1c44575"}}}}, {"uuid": "16562700-f4db-4517-abbb-5aa91fff7652", "name": "d3a5a834-ea15-484f-9dde-fcdb1d49033b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.621947646480353, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0332384495271123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cfd37b6d-06db-482a-afb3-8fa4f7a686b5", "name": "411c31b0-e7a3-40e7-adda-02517fe0908e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "16562700-f4db-4517-abbb-5aa91fff7652"}}}]}, {"uuid": "b83a0389-140e-4844-80a2-41f2bffe2b90", "name": "load_p1rlv854_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2461b6f0-9a40-4b6f-9669-be479da039f3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cfd37b6d-06db-482a-afb3-8fa4f7a686b5"}}}}, {"uuid": "f600b2dc-6cdb-4b19-97ad-d56551e79ab4", "name": "e150596e-4503-4ecf-9026-bf049ae0d6fc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.037961707989467, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3691190849967326, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "224dd4bd-f3ff-4f50-97d3-2fdc005e0de3", "name": "ed0f82f0-768d-456c-b6e9-0ee41ce84c6a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f600b2dc-6cdb-4b19-97ad-d56551e79ab4"}}}]}, {"uuid": "7a5ba2e4-3885-4be5-b672-99b3fae2d8c3", "name": "load_p1rlv855_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10611e08-75e2-4422-ac0f-cfb98c7eae4b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "224dd4bd-f3ff-4f50-97d3-2fdc005e0de3"}}}}, {"uuid": "6e323aa2-ba11-48d0-81ef-41387111c606", "name": "eac6cc37-cbe4-4fb4-8a1d-bc90e9fa3754_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.037961707989467, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3691190849967326, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5c3af5ce-5414-41ea-9c5c-89efe6d0d90a", "name": "93900ca9-c875-4baf-81a9-4f3c3d29dace", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6e323aa2-ba11-48d0-81ef-41387111c606"}}}]}, {"uuid": "ceb6e0a6-d1af-4b49-83a3-ec99e79b538f", "name": "load_p1rlv855_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10611e08-75e2-4422-ac0f-cfb98c7eae4b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5c3af5ce-5414-41ea-9c5c-89efe6d0d90a"}}}}, {"uuid": "6df6841e-86ca-4dec-8dcd-4d1e7737d659", "name": "98ba7850-57fc-45a0-b3e0-7d705b57c157_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0599252267318962, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3748861224482183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "84f46b25-5bba-449b-bb71-0fd1708d7b9c", "name": "e9e7e068-991b-428e-bba2-5378e50498cc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6df6841e-86ca-4dec-8dcd-4d1e7737d659"}}}]}, {"uuid": "621bdbbe-256c-4cc9-be75-89226e86b452", "name": "load_p1rlv856_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25f84b28-695b-4d32-b96c-914226444b9f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "84f46b25-5bba-449b-bb71-0fd1708d7b9c"}}}}, {"uuid": "04f372ca-5429-44cc-8e92-039e9872f677", "name": "c7fc900a-9761-4cd4-8341-b345266840fb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0599252267318962, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3748861224482183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1166a1ab-a5b1-456c-8bd7-a71a202292ff", "name": "d9b7e884-83d2-470d-bda2-9909f008c41d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "04f372ca-5429-44cc-8e92-039e9872f677"}}}]}, {"uuid": "ae996b2d-1dea-4f61-99a5-a53fcb898980", "name": "load_p1rlv856_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25f84b28-695b-4d32-b96c-914226444b9f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1166a1ab-a5b1-456c-8bd7-a71a202292ff"}}}}, {"uuid": "9b8f6789-1de8-413d-a3c4-5410bef958a2", "name": "88d15826-274e-4901-8860-5e4d7a9c38d6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7943609059660943, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8824322096654456, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2eeb66ef-6a15-4ad6-add3-1a48e608df1b", "name": "c859bfb6-b1e9-467f-a6ba-c0a872cd4dac", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9b8f6789-1de8-413d-a3c4-5410bef958a2"}}}]}, {"uuid": "2afb5f2d-a7d6-4d0d-814f-9ed02e37d632", "name": "load_p1rlv857_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a28cc17a-125d-4b7b-a697-230e3f8853b5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2eeb66ef-6a15-4ad6-add3-1a48e608df1b"}}}}, {"uuid": "9aa8e408-47da-4da3-b3eb-a373bf49b2b0", "name": "b4a34dc0-77f6-48fd-974b-3e39b8b29a49_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7943609059660943, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8824322096654456, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "234024af-de66-4b33-8129-d6b8059bdd80", "name": "75c1079f-de07-4098-bd81-29f4198fc437", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9aa8e408-47da-4da3-b3eb-a373bf49b2b0"}}}]}, {"uuid": "094df460-37a3-4b56-a3b9-f5b2b6be0ba3", "name": "load_p1rlv857_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a28cc17a-125d-4b7b-a697-230e3f8853b5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "234024af-de66-4b33-8129-d6b8059bdd80"}}}}, {"uuid": "7323b44d-a2c5-4f50-b500-5800eb2f378e", "name": "a23685aa-5fd7-4cf5-a7a7-40e6e2203420_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.360087651208046, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7361845082285076, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a1c70345-7ac7-4ce2-a973-c7c9094de834", "name": "9a73ab21-8bd4-42fc-8948-6e32c8dee34d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7323b44d-a2c5-4f50-b500-5800eb2f378e"}}}]}, {"uuid": "2d3bce52-a0d9-407c-9a3d-47bad3f824a1", "name": "load_p1rlv858_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab33ce2f-3131-4cfb-8df2-329fb4aa76b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a1c70345-7ac7-4ce2-a973-c7c9094de834"}}}}, {"uuid": "a75b42ea-cf4f-482a-818d-e620e774eaba", "name": "6cd91bc1-b5b9-4e8d-9a2a-e6ae360b7edb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.360087651208046, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7361845082285076, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a51406a8-a8d8-4294-a054-2829c350a2c5", "name": "0b07e4b1-3489-4d32-9b21-cdb8c09841d9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a75b42ea-cf4f-482a-818d-e620e774eaba"}}}]}, {"uuid": "bd4c08fd-1f86-4ca0-861b-d97428390c2a", "name": "load_p1rlv858_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab33ce2f-3131-4cfb-8df2-329fb4aa76b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a51406a8-a8d8-4294-a054-2829c350a2c5"}}}}, {"uuid": "35086a57-9857-4866-a09e-231dd9f6fca0", "name": "e8a02a80-3e02-43f8-86aa-0139292ee6c8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.292799122473319, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5385753507809203, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "092c0dd2-64c4-4fdb-b042-0fba4bd9bd72", "name": "b309218d-ff40-4e21-b696-16d8cb4504e8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "35086a57-9857-4866-a09e-231dd9f6fca0"}}}]}, {"uuid": "ea82bf4d-44fc-471f-bb20-faa13e025ddc", "name": "load_p1rlv859_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ea0f4f5-2024-45a8-9f8f-f5963e7d2727"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "092c0dd2-64c4-4fdb-b042-0fba4bd9bd72"}}}}, {"uuid": "15eca634-df48-414d-a350-28d6a67c60ac", "name": "10d83fbf-95e7-4c47-84ea-795b3e674406_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.292799122473319, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5385753507809203, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4f3dd59b-9b2a-4fa7-b2f0-77b46d74ea85", "name": "5909bc2c-6ea9-400d-a1ac-7ec4cf3b3195", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "15eca634-df48-414d-a350-28d6a67c60ac"}}}]}, {"uuid": "1d319791-32ab-4a13-9b3a-4c28dfee0e16", "name": "load_p1rlv859_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ea0f4f5-2024-45a8-9f8f-f5963e7d2727"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4f3dd59b-9b2a-4fa7-b2f0-77b46d74ea85"}}}}, {"uuid": "3946463d-5ba0-4265-99c7-f95fda7d6324", "name": "c226f9fe-97d4-4f13-a604-ed5ef5335011_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5424601784243566, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31457775613808403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9b716c1f-225f-4a38-b498-7f218bc827ff", "name": "ec4ad5d1-316c-48cc-adf4-d43151ae92d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3946463d-5ba0-4265-99c7-f95fda7d6324"}}}]}, {"uuid": "5ea998e1-259b-4b48-86ae-f263a6e51b5c", "name": "load_p1rlv860_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bada1117-5605-4aec-9314-8013ed243e3c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9b716c1f-225f-4a38-b498-7f218bc827ff"}}}}, {"uuid": "39e0e2ea-3427-41a3-a24c-f874143fd4cf", "name": "c975a955-75c7-4e7c-b1bf-c42d83f0ee8d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5424601784243566, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31457775613808403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ab3bcd05-6f6f-4d10-8807-13db4da37a09", "name": "90e3bd87-98c5-4cff-b849-90a6c5e49d55", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "39e0e2ea-3427-41a3-a24c-f874143fd4cf"}}}]}, {"uuid": "087c8d07-6c8a-4ea0-8c2e-36d042741e85", "name": "load_p1rlv860_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bada1117-5605-4aec-9314-8013ed243e3c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ab3bcd05-6f6f-4d10-8807-13db4da37a09"}}}}, {"uuid": "b615cda8-1baf-4369-99b6-e1aa112b1d04", "name": "b0859b4f-82e2-43c9-a5e7-4d90cbf261fc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2766983969851713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5028612878254624, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2b07c294-9599-4629-ab6a-de6a01d14c82", "name": "e7546a56-0a12-4d9c-8664-ed7e6eb841c1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b615cda8-1baf-4369-99b6-e1aa112b1d04"}}}]}, {"uuid": "96800c02-0db3-4db9-b8b6-28b7fc263295", "name": "load_p1rlv861_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a07d30f-6909-4d74-be8a-1ff8343b4419"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2b07c294-9599-4629-ab6a-de6a01d14c82"}}}}, {"uuid": "4659d82a-2d77-4710-82ac-960b753b0425", "name": "3bbc9222-9155-4c7a-9d39-cb8512724ca8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2766983969851713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5028612878254624, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "72a5a44c-ba79-466f-abea-f385d63ff89d", "name": "e23362be-3012-4f38-9444-437cf2f9fb67", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4659d82a-2d77-4710-82ac-960b753b0425"}}}]}, {"uuid": "1cf2e81e-bfb4-48c2-9ef3-c4244e1d4176", "name": "load_p1rlv861_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a07d30f-6909-4d74-be8a-1ff8343b4419"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "72a5a44c-ba79-466f-abea-f385d63ff89d"}}}}, {"uuid": "36119b84-0eeb-4a54-a521-ea143e122c70", "name": "f8af5d24-b499-47a4-bf61-a9a39a38a305_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.037961707989467, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3691190849967326, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aaa7a400-9669-453e-987b-e49830388166", "name": "b597c1da-1f78-4424-92de-98ee97ef58bd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "36119b84-0eeb-4a54-a521-ea143e122c70"}}}]}, {"uuid": "49da019f-d34e-4676-a7c3-83d7fdd9f1d1", "name": "load_p1rlv862_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5e2c3a2-32c0-4bb9-9802-265cec784974"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aaa7a400-9669-453e-987b-e49830388166"}}}}, {"uuid": "5006d372-3b1d-408c-abe2-6f3208eac730", "name": "ba8b441d-bec1-43f1-8574-b8a92ff222ba_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.037961707989467, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3691190849967326, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f31efed1-ba00-4062-ab30-6e483d25fc84", "name": "210c84bb-bc4c-4f53-ad8c-625114ae5c83", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5006d372-3b1d-408c-abe2-6f3208eac730"}}}]}, {"uuid": "fd3a664f-196a-43fa-bfdc-53efd02af17c", "name": "load_p1rlv862_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5e2c3a2-32c0-4bb9-9802-265cec784974"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f31efed1-ba00-4062-ab30-6e483d25fc84"}}}}, {"uuid": "ace38ad0-adb5-413b-b79d-668ae95cb220", "name": "ceae3b7d-532d-4b92-a59b-64dee73af957_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1350143243427975, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1351898450115188, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d7fbc366-1f07-41d0-bec5-af65c6df29d4", "name": "15d9ac3c-7a40-46a9-9835-115380acddf0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ace38ad0-adb5-413b-b79d-668ae95cb220"}}}]}, {"uuid": "5966ebaa-cfd3-4095-ade4-1f653ab63ea7", "name": "load_p1rlv863_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09a7be46-a1bf-459d-836b-beb64324809b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d7fbc366-1f07-41d0-bec5-af65c6df29d4"}}}}, {"uuid": "1d53c84b-81f1-420c-8482-438a751eed35", "name": "3da80d10-b10f-4974-a8f9-5dd2816e5bd9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1350143243427975, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1351898450115188, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "37c8776e-dbfe-404b-b52e-a7685eca1be1", "name": "e545727b-1cfe-4117-be2f-530ecedfdadf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1d53c84b-81f1-420c-8482-438a751eed35"}}}]}, {"uuid": "7033a7f2-be4e-454a-a54a-997dfcea2f79", "name": "load_p1rlv863_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09a7be46-a1bf-459d-836b-beb64324809b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "37c8776e-dbfe-404b-b52e-a7685eca1be1"}}}}, {"uuid": "679bc03a-95ec-4dac-b478-740fb11b7f8b", "name": "026f57e0-a554-4cd6-aff1-1162bc769970_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0404861968223509, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5307917165881004, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0b92cee6-e830-479d-98b9-5b58f61604e9", "name": "d677f903-718f-4ebe-acc8-9aa5591d70a4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "679bc03a-95ec-4dac-b478-740fb11b7f8b"}}}]}, {"uuid": "7fb1a340-9cdd-4d27-87c6-975d10aab344", "name": "load_p1rlv864_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e2a8871-7bc4-497f-9954-38db92cb3eba"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0b92cee6-e830-479d-98b9-5b58f61604e9"}}}}, {"uuid": "51792ec8-29d7-4f26-8ccf-07b1c59ea1fe", "name": "441a7382-13b0-4a4b-a9cb-a6efc1080bce_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0404861968223509, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5307917165881004, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50e57df0-1fc7-4e3b-a217-56d086a3f85d", "name": "f845ac47-866f-4ed9-bd8d-b7b2968e8703", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "51792ec8-29d7-4f26-8ccf-07b1c59ea1fe"}}}]}, {"uuid": "5f436709-285d-4efc-b7a5-b90e8d251195", "name": "load_p1rlv864_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e2a8871-7bc4-497f-9954-38db92cb3eba"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50e57df0-1fc7-4e3b-a217-56d086a3f85d"}}}}, {"uuid": "38cc0407-c5ca-4e8b-89f6-76d0f546dc24", "name": "222da507-c072-4b19-a029-97d7de16ca33_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.396349422902612, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13402564403017767, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a83ec3a0-5d64-4bfe-ae1a-d5fb9a412442", "name": "d6ed423b-17ab-463e-9c6f-6c4ea05e864c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "38cc0407-c5ca-4e8b-89f6-76d0f546dc24"}}}]}, {"uuid": "c2714419-2921-4ab1-b9c6-5aa354bac9c6", "name": "load_p1rlv865_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abdfa5db-c398-4638-805d-6d55597e1921"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a83ec3a0-5d64-4bfe-ae1a-d5fb9a412442"}}}}, {"uuid": "8144f7d5-cfad-47c7-bc29-c99638c052ee", "name": "5a0fbef2-a383-4d19-b9b5-a19466da2dcf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.396349422902612, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13402564403017767, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6527d9ad-e156-4133-acb9-f3e5763eec6c", "name": "d1944846-4e8d-4ef5-8a4c-1555100cb335", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8144f7d5-cfad-47c7-bc29-c99638c052ee"}}}]}, {"uuid": "13136e7a-d669-4975-b669-a1c432915c92", "name": "load_p1rlv865_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abdfa5db-c398-4638-805d-6d55597e1921"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6527d9ad-e156-4133-acb9-f3e5763eec6c"}}}}, {"uuid": "42bfd63a-37b3-4f04-8158-3ef4471651bf", "name": "3f3992b8-a126-4bb3-b05c-89840855c1f0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3885774782241163, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12624891415512582, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "560745e8-0452-43ef-81d7-630181294706", "name": "cce335ea-f452-48ad-8707-9c2d3280e24c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "42bfd63a-37b3-4f04-8158-3ef4471651bf"}}}]}, {"uuid": "b2b6fa33-8085-4b64-82cd-4fe96219ea44", "name": "load_p1rlv866_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b4834dc-6bdf-4102-bc13-589392b2e75a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "560745e8-0452-43ef-81d7-630181294706"}}}}, {"uuid": "968e05c7-a79f-4514-a3de-87e33419cff2", "name": "85ae0cf9-82bc-4d01-b049-fcd4b6fb9ac1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3885774782241163, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12624891415512582, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d1de2c42-fc5f-4cb4-92ec-5e9beac9c261", "name": "c12a43c2-a29e-4bcd-bdeb-7a0306225d8c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "968e05c7-a79f-4514-a3de-87e33419cff2"}}}]}, {"uuid": "faa57801-b454-43b6-bdda-eeaafa76b9e8", "name": "load_p1rlv866_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b4834dc-6bdf-4102-bc13-589392b2e75a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d1de2c42-fc5f-4cb4-92ec-5e9beac9c261"}}}}, {"uuid": "1c879820-7c35-46b9-8168-00f7e509aef4", "name": "403f8627-c8d6-40e8-bfcb-47c03dcf74d8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6434260893942235, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2588956175598443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "171928bd-80b9-42bb-a91e-b9ab7ae8989a", "name": "f8b5b9e7-4f04-4cdd-bb13-380da2aeb0ea", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1c879820-7c35-46b9-8168-00f7e509aef4"}}}]}, {"uuid": "c6967476-77ef-442f-bfdb-222f6502e733", "name": "load_p1rlv867_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a7cca48-fd4b-4630-a479-55f2b6ada03b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "171928bd-80b9-42bb-a91e-b9ab7ae8989a"}}}}, {"uuid": "114181e2-86b0-4925-9cc9-0d7ca64c7407", "name": "1c2a3eea-1172-431e-87b2-17ad9df21235_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6434260893942235, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2588956175598443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "28a7f3f9-cd2e-428a-a9bd-d33a2e4fed11", "name": "0de580cd-f883-4a16-8008-61a93c33a7da", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "114181e2-86b0-4925-9cc9-0d7ca64c7407"}}}]}, {"uuid": "385a2115-4295-4941-a7fb-a59564b4f508", "name": "load_p1rlv867_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a7cca48-fd4b-4630-a479-55f2b6ada03b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "28a7f3f9-cd2e-428a-a9bd-d33a2e4fed11"}}}}, {"uuid": "b9f7f963-fb43-4e1e-871d-38f0d87206ca", "name": "a1d0da70-7bc9-493c-94ef-abe966f8bcdb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b25e2402-e84a-4a40-80a0-ce8be1a5322b", "name": "2e2a91d1-2bc1-4316-a111-5371893ddf75", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b9f7f963-fb43-4e1e-871d-38f0d87206ca"}}}]}, {"uuid": "2e469aa9-dbf8-4b95-8f28-e8a2fb8c1ea1", "name": "load_p1rlv868_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "009758e3-b4ae-427a-9c30-f2a8bb2953d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b25e2402-e84a-4a40-80a0-ce8be1a5322b"}}}}, {"uuid": "8328adfe-9dc1-4885-b0eb-17be3134c569", "name": "18746686-2a2d-4f4e-bad6-fd16dbe2a33f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "467c6f11-7830-4b68-b6d9-a210abde83f1", "name": "18413f31-a538-4d0d-bd03-11a127f553d3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8328adfe-9dc1-4885-b0eb-17be3134c569"}}}]}, {"uuid": "547a971b-dbf5-4c1f-91ab-7385e3c89f7a", "name": "load_p1rlv868_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "009758e3-b4ae-427a-9c30-f2a8bb2953d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "467c6f11-7830-4b68-b6d9-a210abde83f1"}}}}, {"uuid": "eb92c93e-422c-40d0-b704-4fc3df412ad6", "name": "ffe3ad19-366b-4fd2-9f71-a5b150b6eb7c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.338024948143216, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9096814401074484, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d3416bc5-2dff-48ff-a630-f670458c570d", "name": "d0e0e291-1ed0-4993-8ee3-a05937ce6327", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eb92c93e-422c-40d0-b704-4fc3df412ad6"}}}]}, {"uuid": "4d86c288-ca8d-41fb-8c4d-b10435f7da15", "name": "load_p1rlv869_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fb4003d-498a-494d-89ca-f222d921f63a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d3416bc5-2dff-48ff-a630-f670458c570d"}}}}, {"uuid": "3201dcf9-4b41-468e-a205-000c11004b4e", "name": "6dcbacc4-865b-4a74-be53-090263776564_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.338024948143216, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9096814401074484, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b7edcd35-a7b1-48bc-af27-1b3853eb3475", "name": "6f04df3d-66d0-447a-92b9-abd6bf18984b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3201dcf9-4b41-468e-a205-000c11004b4e"}}}]}, {"uuid": "61512b03-7ff1-4d52-8b9f-426e1d071061", "name": "load_p1rlv869_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fb4003d-498a-494d-89ca-f222d921f63a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b7edcd35-a7b1-48bc-af27-1b3853eb3475"}}}}, {"uuid": "c5372011-7783-401d-9a42-ba2d894a238e", "name": "f1f19423-67b8-402b-8984-0f898b9811cf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4212042062341066, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7562106926743815, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7dbdc0a2-3f64-4373-859d-3a26df047799", "name": "eb64a4e4-6070-40ec-bc13-6a2922d7cd73", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c5372011-7783-401d-9a42-ba2d894a238e"}}}]}, {"uuid": "4d51d8cd-d0e6-4b8e-a4ad-5247983a09be", "name": "load_p1rlv7783_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd7a84bb-8aa4-4668-9791-a363741823e9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7dbdc0a2-3f64-4373-859d-3a26df047799"}}}}, {"uuid": "356fabb2-65b3-430b-a312-5aa18a3c401c", "name": "13d0f027-f3af-4bb2-82ae-f9bbfede334a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4212042062341066, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7562106926743815, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7341ff5f-3431-4fc3-8e0b-f52c7bc7373a", "name": "d5d33575-ebee-4695-b382-0da403d99f1f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "356fabb2-65b3-430b-a312-5aa18a3c401c"}}}]}, {"uuid": "e04e1abb-c60f-41f0-a774-c47db62edcb7", "name": "load_p1rlv7783_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd7a84bb-8aa4-4668-9791-a363741823e9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7341ff5f-3431-4fc3-8e0b-f52c7bc7373a"}}}}, {"uuid": "1713edaf-ac0f-44a1-98ba-b0cce436bc52", "name": "17302292-37b7-4d04-a4ad-5f84bccad702_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7101501378288513, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4527501720520811, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0199c07e-7ae5-4eae-8840-bc887b10f47c", "name": "21e0d40f-8044-479d-8281-30ccfe9937af", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1713edaf-ac0f-44a1-98ba-b0cce436bc52"}}}]}, {"uuid": "96a58958-439a-468e-b3d9-56cbf024da8c", "name": "load_p1rlv7784_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24e665a0-3ba6-46a7-bc02-327b6f77c409"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0199c07e-7ae5-4eae-8840-bc887b10f47c"}}}}, {"uuid": "dcdf6c24-e443-4d30-b513-55002574edab", "name": "b5c7351b-44db-4dad-a029-13aaf73a1b56_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7101501378288513, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4527501720520811, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "96ae4a60-29b4-4c2a-994d-969e5605b8e5", "name": "ba592037-68f9-4d58-8f80-54b47f0019dc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dcdf6c24-e443-4d30-b513-55002574edab"}}}]}, {"uuid": "0dd29067-5363-4676-abfc-354c6ff02846", "name": "load_p1rlv7784_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24e665a0-3ba6-46a7-bc02-327b6f77c409"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "96ae4a60-29b4-4c2a-994d-969e5605b8e5"}}}}, {"uuid": "1f4bd4b8-5e77-4a63-b4ce-b7fb5e07d7d7", "name": "00369e15-8a8a-4925-b8e2-ab8a0b504b7f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7392455382108751, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4362253237121403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "810e40dc-14f6-45be-b35f-0f870f133692", "name": "5b77ab36-8077-415f-aa20-26ad0a9095f3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1f4bd4b8-5e77-4a63-b4ce-b7fb5e07d7d7"}}}]}, {"uuid": "b29d32c3-c841-4de0-a9bb-6c3bd598ecf0", "name": "load_p1rlv7785_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1571d1a3-a151-4972-8cb1-aeb36b660abc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "810e40dc-14f6-45be-b35f-0f870f133692"}}}}, {"uuid": "fe5e92cf-14d5-40c8-80c9-994efda6330b", "name": "2c63d8f0-6314-4200-907f-007d8fdc7b8a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7392455382108751, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4362253237121403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8eb3fe60-7f0f-4d31-96ea-b471cece8da8", "name": "010de59b-39bf-4135-9331-e5121db1ff1d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fe5e92cf-14d5-40c8-80c9-994efda6330b"}}}]}, {"uuid": "491c2e8e-4768-402a-9265-b6aed108f402", "name": "load_p1rlv7785_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1571d1a3-a151-4972-8cb1-aeb36b660abc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8eb3fe60-7f0f-4d31-96ea-b471cece8da8"}}}}, {"uuid": "c4d52b83-c123-4dad-a510-e4e0acb90ef8", "name": "86cc9856-6517-480c-bd1f-5cb3042f8f64_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4818511326065424, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6748395523926414, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e73684a1-b61e-4422-a2d1-b6d0db4ad5cb", "name": "e55cf8bd-e951-4401-887c-da8167795169", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c4d52b83-c123-4dad-a510-e4e0acb90ef8"}}}]}, {"uuid": "199b5478-37e0-4ed6-8017-12a45432003a", "name": "load_p1rlv7786_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af62e3c-9357-4505-a2f6-3b4252dab81b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e73684a1-b61e-4422-a2d1-b6d0db4ad5cb"}}}}, {"uuid": "34a004b2-eea5-415a-8e47-262212d2a7d5", "name": "d016a180-f514-4118-b5ab-0bee72e27724_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4818511326065424, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6748395523926414, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "105167fd-90f0-40a8-a0b1-c598a4aff4a7", "name": "26f2e62d-d3bb-478c-b5ad-f367a0eca836", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "34a004b2-eea5-415a-8e47-262212d2a7d5"}}}]}, {"uuid": "3dd5337e-db69-4d76-b98f-47d0ed2a0fa6", "name": "load_p1rlv7786_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af62e3c-9357-4505-a2f6-3b4252dab81b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "105167fd-90f0-40a8-a0b1-c598a4aff4a7"}}}}, {"uuid": "98e8bc3a-ae30-47a4-b7d1-281b95a25c74", "name": "457cbb44-1f6e-4e4a-a8d2-a1c3fd8ad123_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9705664843982345, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20295664886439999, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10ff4285-30ed-41a3-8f7e-9ebc82a27b21", "name": "5374c77e-7f21-431e-a7b2-e576db6ca92a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "98e8bc3a-ae30-47a4-b7d1-281b95a25c74"}}}]}, {"uuid": "5377086a-e04a-491c-8e54-efd38306a144", "name": "load_p1rlv10453_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09926231-b077-4aa6-afd8-acf89744865a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10ff4285-30ed-41a3-8f7e-9ebc82a27b21"}}}}, {"uuid": "8a0a012e-28ce-42d7-a4bd-9ee349d700bc", "name": "25f0cc32-c195-40fb-83d4-0d08a5fdd278_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9705664843982345, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20295664886439999, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fbc1bd32-f7d7-4287-adfb-b99cc1a70bc5", "name": "d67682f3-c1e0-4618-abe0-2b29d2af39ff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a0a012e-28ce-42d7-a4bd-9ee349d700bc"}}}]}, {"uuid": "bd7d0a1e-d67b-4a4e-a2c0-a7a1b73037af", "name": "load_p1rlv10453_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09926231-b077-4aa6-afd8-acf89744865a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fbc1bd32-f7d7-4287-adfb-b99cc1a70bc5"}}}}, {"uuid": "10730986-0710-4e81-990f-23beb309d894", "name": "c2d3e7d3-19b1-44f4-b6fa-b8cd5157c579_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9288135994675786, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3237835349774649, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4db3bb81-f55f-4f61-a851-1a862c76b727", "name": "58e3f632-f96c-40e1-a83e-23ef309dba25", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "10730986-0710-4e81-990f-23beb309d894"}}}]}, {"uuid": "3a7f5ff3-b2dd-454a-99fc-5b591d560ba5", "name": "load_p1rlv10468_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a639e8d-ac8c-46e8-a4b5-6c551612b209"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4db3bb81-f55f-4f61-a851-1a862c76b727"}}}}, {"uuid": "c7776e75-cfc5-4157-8f3a-7503c9711283", "name": "20e4f9b1-b0fa-458b-b0ce-e9170c32f91d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9288135994675786, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3237835349774649, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a6dc196c-5ae1-4ab2-805f-2810cbff7632", "name": "5083f26e-7835-4fd1-93f4-b27ec12194b4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c7776e75-cfc5-4157-8f3a-7503c9711283"}}}]}, {"uuid": "339c7105-f33b-45e5-abcf-ef13c4974cbf", "name": "load_p1rlv10468_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a639e8d-ac8c-46e8-a4b5-6c551612b209"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a6dc196c-5ae1-4ab2-805f-2810cbff7632"}}}}, {"uuid": "c1025d61-e42a-41dd-8a3c-2bb129424d05", "name": "a10cf00c-67ac-4213-ad57-a683b93ef409_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.137360281336931, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.443734948632237, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c8407680-4514-4a23-a4e1-14107c4aa215", "name": "00e230a2-ffb8-423f-88ad-611c74946da7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c1025d61-e42a-41dd-8a3c-2bb129424d05"}}}]}, {"uuid": "d5c520ff-f7a9-48be-870b-1d2208006878", "name": "load_p1rlv10482_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d40fc87f-1b73-4ed4-a397-dbc94312dcad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c8407680-4514-4a23-a4e1-14107c4aa215"}}}}, {"uuid": "6634dc96-29a7-43b5-81a6-334cba43847c", "name": "e237970c-6462-4344-af07-c9d1ad1343a4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.137360281336931, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.443734948632237, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e887fdb7-614b-4d04-b57a-0d1cc3fd571e", "name": "00e2e47e-f8b0-489e-947f-2a9f364dce18", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6634dc96-29a7-43b5-81a6-334cba43847c"}}}]}, {"uuid": "997faa1f-d5f7-441a-869d-4e69da540525", "name": "load_p1rlv10482_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d40fc87f-1b73-4ed4-a397-dbc94312dcad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e887fdb7-614b-4d04-b57a-0d1cc3fd571e"}}}}, {"uuid": "fe4be1fd-0512-4eb7-9f7f-11886ff23ff1", "name": "64750c64-f3ba-45b1-816b-750e7b1e9b4d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.982015016710447, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5720113989287618, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "078f82f7-4f75-410d-a499-337abb2ebaac", "name": "3e87d6fc-2a31-40a4-9ce4-830ded723b7a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fe4be1fd-0512-4eb7-9f7f-11886ff23ff1"}}}]}, {"uuid": "cca90958-3097-4288-b429-b28e1fd1caf7", "name": "load_p1rlv10517_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "efd01236-6ba3-424e-829b-3f3950ce6265"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "078f82f7-4f75-410d-a499-337abb2ebaac"}}}}, {"uuid": "a170ae41-2689-494f-aa57-d9df60f90d08", "name": "c9c3960e-61bf-4a9b-bba7-44c9143e27e6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.982015016710447, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5720113989287618, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "269b3854-5224-400f-839d-f2b589390694", "name": "d192040d-7e21-4a69-b5fb-8ea8137bca90", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a170ae41-2689-494f-aa57-d9df60f90d08"}}}]}, {"uuid": "36344287-a32a-46aa-a960-835474341ea3", "name": "load_p1rlv10517_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "efd01236-6ba3-424e-829b-3f3950ce6265"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "269b3854-5224-400f-839d-f2b589390694"}}}}, {"uuid": "adcf0a93-9a94-431d-9ebc-6835e5a8059a", "name": "2036e332-5afc-465e-9d87-d99c6f411b95_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.160991762543576, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9056130261441641, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2c486189-5467-480d-a6ad-ae7c6290458c", "name": "eaabd49c-a213-4fd5-9cca-291701c002fa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "adcf0a93-9a94-431d-9ebc-6835e5a8059a"}}}]}, {"uuid": "65822cb1-153e-4fbc-8610-1b9fc2dc485c", "name": "load_p1rlv11503_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "773a6b9e-d708-4f7c-a901-9406bcc3dcde"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2c486189-5467-480d-a6ad-ae7c6290458c"}}}}, {"uuid": "6799b0b2-e42f-4ddc-bc71-b87a75fc8f59", "name": "edc9e2eb-7c62-47ab-ba2c-c1119079824a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.160991762543576, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9056130261441641, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c30fe11c-27f9-4a6f-8a66-50f3396162a4", "name": "834f3ff6-6233-4dd4-a5a0-dafe3f984f1b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6799b0b2-e42f-4ddc-bc71-b87a75fc8f59"}}}]}, {"uuid": "6949907d-ea62-46ba-b015-cc5a3054b94b", "name": "load_p1rlv11503_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "773a6b9e-d708-4f7c-a901-9406bcc3dcde"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c30fe11c-27f9-4a6f-8a66-50f3396162a4"}}}}, {"uuid": "320bb1ad-fb4a-4e8a-991d-a2cef4662f2b", "name": "45904608-adc0-44ee-b20b-377a44260f1c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 15.606876661659024, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.2167580478298823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a224ecb-4f16-4ea5-8f6f-384ece3a523c", "name": "45904608-adc0-44ee-b20b-377a44260f1c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 15.606876661659024, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.2167580478298823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "68e57e33-9943-44b8-b264-b5560c1d4b4c", "name": "45904608-adc0-44ee-b20b-377a44260f1c_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 15.606876661659024, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.2167580478298823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4748482d-bd45-4d2c-870e-3fb5e1a21449", "name": "a4709721-35d1-451c-abcd-4ef6fdbb9e7c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "320bb1ad-fb4a-4e8a-991d-a2cef4662f2b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0a224ecb-4f16-4ea5-8f6f-384ece3a523c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "68e57e33-9943-44b8-b264-b5560c1d4b4c"}}}]}, {"uuid": "1c4e8311-a62b-4a80-b43d-dc5ded5311c3", "name": "load_p1rlv11506", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "82988650-787d-41de-bca7-4f3c08ccad15"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4748482d-bd45-4d2c-870e-3fb5e1a21449"}}}}, {"uuid": "95c9105d-b00f-4e2d-932b-b74067800d34", "name": "cefbed57-dfef-4d79-b045-a385ca1060a0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 10.178690882168185, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.8011442962112136, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4addb2d3-a678-4527-be47-baab300fcbc5", "name": "1bf14111-5b0a-48df-9573-c9b4a0915629", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "95c9105d-b00f-4e2d-932b-b74067800d34"}}}]}, {"uuid": "be46345e-157c-4ee5-8acb-761ea129e52c", "name": "load_p1rlv11513_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84b9d44e-2c8d-4cee-a9d2-327a41ab8dad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4addb2d3-a678-4527-be47-baab300fcbc5"}}}}, {"uuid": "a8ab0468-5638-4f7a-8350-694c2857b3b2", "name": "abaaafc3-3725-42e3-a946-bd918dcaad8f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 10.178690882168185, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.8011442962112136, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ec915dd7-5306-43d9-aa73-5e9131b64835", "name": "c54f0076-4198-48b3-b38d-657bf46d4e2e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a8ab0468-5638-4f7a-8350-694c2857b3b2"}}}]}, {"uuid": "622a3b87-1a77-42d7-ba31-d9a7b2703765", "name": "load_p1rlv11513_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84b9d44e-2c8d-4cee-a9d2-327a41ab8dad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ec915dd7-5306-43d9-aa73-5e9131b64835"}}}}, {"uuid": "c66757e7-156b-47a2-bf3c-60b350e5671b", "name": "227d777e-40c2-48b4-90bb-65961da9a105_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2659851154673674, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7880475847724098, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0b50e2b1-205e-433c-9316-e198d133f206", "name": "54b20506-3d9b-4132-851d-4475eebc75b2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c66757e7-156b-47a2-bf3c-60b350e5671b"}}}]}, {"uuid": "a94a1d11-35e4-461d-ba20-7085e88df6a2", "name": "load_p1rlv11516_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86d82a1e-1596-4fb3-9f3d-44c9553396d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0b50e2b1-205e-433c-9316-e198d133f206"}}}}, {"uuid": "9cb4e692-7ff1-4d87-82a1-033a7139968e", "name": "791e23e8-102a-43c4-baa3-d5c8ae44f2d8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2659851154673674, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7880475847724098, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d679bb72-207d-4856-892d-58dd46d23339", "name": "c7194d59-734a-4c7d-839b-5429638241f6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9cb4e692-7ff1-4d87-82a1-033a7139968e"}}}]}, {"uuid": "050ba298-c20a-4ec0-beb3-b94e3808c5ec", "name": "load_p1rlv11516_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86d82a1e-1596-4fb3-9f3d-44c9553396d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d679bb72-207d-4856-892d-58dd46d23339"}}}}, {"uuid": "e89a76ae-f8b2-42fb-a46a-b59b5774aa94", "name": "10fb628e-fe01-4f5b-b631-dd5fda3853b9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.902887215219663, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.111231385342157, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10ea2792-e7fa-4609-8180-c5ffb4d298ea", "name": "e8c790b6-8571-498c-b018-36135359b8db", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e89a76ae-f8b2-42fb-a46a-b59b5774aa94"}}}]}, {"uuid": "8299b35d-b954-47de-8828-e54a4b3d5896", "name": "load_p1rlv11517_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "179d1d84-0dfe-4920-a039-009f33bc1d8d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10ea2792-e7fa-4609-8180-c5ffb4d298ea"}}}}, {"uuid": "9653af9d-2182-458d-b7b2-1dc199a9116d", "name": "6017e7e0-c29c-4d8b-8bde-e5e9ca1f6340_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.902887215219663, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.111231385342157, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a479e565-1151-4019-80aa-a642f090d9be", "name": "0ab2c7d4-ca0c-4bcc-af61-7866d7984102", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9653af9d-2182-458d-b7b2-1dc199a9116d"}}}]}, {"uuid": "b740edad-3e1a-4df3-afce-70e52538d492", "name": "load_p1rlv11517_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "179d1d84-0dfe-4920-a039-009f33bc1d8d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a479e565-1151-4019-80aa-a642f090d9be"}}}}, {"uuid": "bccabf64-2cc5-4387-9063-037efea74407", "name": "1861f9e2-4187-4864-b570-207cc6126bb6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.815209062299411, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.284220525554307, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7f72e181-164e-4eca-9e0b-189f57e4a521", "name": "1861f9e2-4187-4864-b570-207cc6126bb6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.815209062299411, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.284220525554307, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d62011ec-36d9-4fd0-b81f-4d5f7e76902d", "name": "1861f9e2-4187-4864-b570-207cc6126bb6_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.815209062299411, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.284220525554307, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "615c3356-445c-4f98-b970-8b8bcf87321c", "name": "e30959d0-13f7-44fe-86ec-b383372d22e1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bccabf64-2cc5-4387-9063-037efea74407"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7f72e181-164e-4eca-9e0b-189f57e4a521"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d62011ec-36d9-4fd0-b81f-4d5f7e76902d"}}}]}, {"uuid": "2948aa17-5f03-4d92-9ea6-60b285cfde09", "name": "load_p1rlv11520", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22054033-4e69-41b0-b321-a4d086d20574"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "615c3356-445c-4f98-b970-8b8bcf87321c"}}}}, {"uuid": "376e485b-5ffb-4d5a-ab9c-64c132605a26", "name": "0650d81b-3963-4552-9f0d-b6acae375567_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.368937976023913, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.122061037955929, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e7fbaefc-92c8-4fa6-a238-3e6675385749", "name": "6d7f0b7e-8a13-40aa-91d7-3116020e24e4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "376e485b-5ffb-4d5a-ab9c-64c132605a26"}}}]}, {"uuid": "24ac8477-c762-4578-83f9-36c4764ce044", "name": "load_p1rlv11521_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8f0f8a2-f528-45bd-8fbd-22f6699fe7e0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e7fbaefc-92c8-4fa6-a238-3e6675385749"}}}}, {"uuid": "caae9a53-cd7f-4831-9508-c2fee2b76934", "name": "0a722b1d-473f-4b6c-95f4-4fbd79aa4363_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.368937976023913, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.122061037955929, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f0b2e0be-2a69-47bc-afc9-0bb2f64630a5", "name": "b13519da-e21b-4c44-92a3-01a34458956d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "caae9a53-cd7f-4831-9508-c2fee2b76934"}}}]}, {"uuid": "80fb38d5-a103-45ea-86fb-d8189b370241", "name": "load_p1rlv11521_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8f0f8a2-f528-45bd-8fbd-22f6699fe7e0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f0b2e0be-2a69-47bc-afc9-0bb2f64630a5"}}}}, {"uuid": "4fed72ed-a1e0-4262-aaaf-9c856ccf37b2", "name": "52385853-2633-446a-b93e-aa1b1774eb15_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.71666338297624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.8739990837811158, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0aae9508-102f-4e20-96f8-94b35ed671f6", "name": "52385853-2633-446a-b93e-aa1b1774eb15_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.71666338297624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.8739990837811158, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cc9d9e94-7981-4ee8-bcbf-f5701ba564c1", "name": "52385853-2633-446a-b93e-aa1b1774eb15_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.71666338297624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.8739990837811158, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2a91d892-91c6-46ae-8e47-a9f3b59fc4eb", "name": "41d8b914-1843-44e5-9884-4acfb3532ffa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4fed72ed-a1e0-4262-aaaf-9c856ccf37b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0aae9508-102f-4e20-96f8-94b35ed671f6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cc9d9e94-7981-4ee8-bcbf-f5701ba564c1"}}}]}, {"uuid": "c6a2d41d-89f4-40a1-ae53-15df7b87dd3d", "name": "load_p1rlv11522", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "176b348f-9ecf-4a82-bdf9-f2e5d5a07af7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2a91d892-91c6-46ae-8e47-a9f3b59fc4eb"}}}}, {"uuid": "2e1897ab-fffe-4051-9e23-ec687c8aef6d", "name": "c465d6c6-c4fd-4311-bd32-332bd93cf1cb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 20.596071016561904, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.1080231298812775, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2c067e42-b521-4917-b01a-4328455c627c", "name": "e109b65b-daae-4732-99bc-a5349c5862f2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2e1897ab-fffe-4051-9e23-ec687c8aef6d"}}}]}, {"uuid": "f928863f-0387-490e-b720-40d3ac320fcc", "name": "load_p1rlv11523_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69eba934-3f80-4abc-b5e8-9cdc79aa05a3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2c067e42-b521-4917-b01a-4328455c627c"}}}}, {"uuid": "e0a9ad2d-dbd1-4237-b3e2-5ec5a2c10f3a", "name": "9bcd81db-6dfb-40ba-bf8d-fd41202caeaf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 20.596071016561904, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.1080231298812775, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4899fddb-d844-4080-b45a-7bccd4a40de6", "name": "994ac187-1add-4de4-94e1-448e7bd00ee9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e0a9ad2d-dbd1-4237-b3e2-5ec5a2c10f3a"}}}]}, {"uuid": "a80e2788-c6e3-46ce-955b-5bef549c5386", "name": "load_p1rlv11523_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69eba934-3f80-4abc-b5e8-9cdc79aa05a3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4899fddb-d844-4080-b45a-7bccd4a40de6"}}}}, {"uuid": "65d4d5d7-783c-4164-9c8c-6c80d4c32877", "name": "fbee6fff-73fa-44c2-88bb-e8f585e06115_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.560490892963857, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.302618625091914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10815e19-d32c-4147-a949-9fef4a5bc497", "name": "4ab78c27-a37e-49bf-b595-8b2419cac41f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "65d4d5d7-783c-4164-9c8c-6c80d4c32877"}}}]}, {"uuid": "d8524e9d-cf8b-47cd-92c0-a98c04a69555", "name": "load_p1rlv11526_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b97ebb0-09a4-4c42-a10e-e3aff344aa44"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10815e19-d32c-4147-a949-9fef4a5bc497"}}}}, {"uuid": "51e5b752-3e23-46c1-9104-8d1d07336b1f", "name": "088aeaee-f16d-455b-b6d9-55ceb9ab8cb3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.560490892963857, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.302618625091914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d2e76bd6-ce54-4e45-afc2-c40a892add08", "name": "88cdaf35-1444-46f0-8a69-9a7b75dfe1b2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "51e5b752-3e23-46c1-9104-8d1d07336b1f"}}}]}, {"uuid": "262f3cf0-072f-4bb0-ae69-bed19095daee", "name": "load_p1rlv11526_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b97ebb0-09a4-4c42-a10e-e3aff344aa44"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d2e76bd6-ce54-4e45-afc2-c40a892add08"}}}}, {"uuid": "081b87d0-9953-4e94-a14c-6869f5aff188", "name": "9e28f35b-2950-4018-b931-ce4c4c0e68c5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.930214175792893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.08514782397789, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c4f46244-6662-4298-a101-badc385e322a", "name": "a13bffde-fdec-4d49-9362-91ba5f7576b4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "081b87d0-9953-4e94-a14c-6869f5aff188"}}}]}, {"uuid": "9a43a335-3b65-4527-a2e0-01cfe39458a8", "name": "load_p1rlv11533_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21b18539-fba6-4b52-b8bf-38c2a6c4abfb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c4f46244-6662-4298-a101-badc385e322a"}}}}, {"uuid": "99521e7b-f1a6-438c-98d8-173782182e76", "name": "bab3eb24-732d-46b7-8d01-cd470539adfe_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.930214175792893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.08514782397789, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4fd952c7-7b2a-4e24-9952-342418d3823b", "name": "9ff22554-db4e-4376-8f63-da8436d1a4e4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "99521e7b-f1a6-438c-98d8-173782182e76"}}}]}, {"uuid": "8b08b8fd-c3d6-4cf2-84f5-3a95d96b51ad", "name": "load_p1rlv11533_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21b18539-fba6-4b52-b8bf-38c2a6c4abfb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4fd952c7-7b2a-4e24-9952-342418d3823b"}}}}, {"uuid": "ddf295d3-4ca7-45b8-bab0-2d2bedc79adf", "name": "164eb96d-8724-440d-841e-984dfc18b446_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.679125701108364, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8113232260660387, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "11b71362-a9ff-4ef3-91d7-b68749e0d98c", "name": "ae9b73d9-29a3-4d82-a958-b574c12d172e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ddf295d3-4ca7-45b8-bab0-2d2bedc79adf"}}}]}, {"uuid": "0920b786-6c42-4116-a887-236dade23449", "name": "load_p1rlv11540_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f79b14c8-e77d-49c1-9336-e7407ad4c94d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "11b71362-a9ff-4ef3-91d7-b68749e0d98c"}}}}, {"uuid": "8e30adb3-f06b-4cd3-bb78-0d53c73b9a12", "name": "a65e0dea-444d-422c-859a-f131dddcc40d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.679125701108364, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8113232260660387, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5b1b211b-f5c6-4161-9358-4937f7abcf73", "name": "9a4b4965-a41b-4d43-a8a7-48fa3accb31f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8e30adb3-f06b-4cd3-bb78-0d53c73b9a12"}}}]}, {"uuid": "e4f076a8-8c21-4468-995f-cb3d3a523c31", "name": "load_p1rlv11540_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f79b14c8-e77d-49c1-9336-e7407ad4c94d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5b1b211b-f5c6-4161-9358-4937f7abcf73"}}}}, {"uuid": "4fa4e50c-0268-4490-9d23-af532cb741af", "name": "ed9a947f-533f-4db7-9220-295975ae80ed_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c32e1d70-5898-46d9-bdfe-474a13392868", "name": "68ccf7df-d110-494b-be42-8264b9530d4d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4fa4e50c-0268-4490-9d23-af532cb741af"}}}]}, {"uuid": "4c5802e3-88ed-4e3e-929b-910aeb4c85f1", "name": "load_p1rlv13033_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1564c5f9-8b80-41b4-af09-2a55dee0718b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c32e1d70-5898-46d9-bdfe-474a13392868"}}}}, {"uuid": "ce96a1c1-4da1-4feb-ab24-94101677e52a", "name": "ac092c22-a341-4f4b-8b0e-06392057556b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "629c4abf-b246-4c2f-be64-fc45ce958904", "name": "2dca5672-682f-4a17-8c6a-9c7e92a4b7c3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ce96a1c1-4da1-4feb-ab24-94101677e52a"}}}]}, {"uuid": "ad7a7ba1-03a7-421c-af74-453a372d2ea2", "name": "load_p1rlv13033_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1564c5f9-8b80-41b4-af09-2a55dee0718b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "629c4abf-b246-4c2f-be64-fc45ce958904"}}}}, {"uuid": "c09b2358-e1d4-413e-b86c-89d5aeea06c6", "name": "709debc3-2c8b-473c-b17c-aa380a193726_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.074192704000552, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.129078804753558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a399b34-ceb0-4ca8-ab6b-fbeb5d6f11c7", "name": "2f4af060-e488-4b5c-bbdc-53115064906c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c09b2358-e1d4-413e-b86c-89d5aeea06c6"}}}]}, {"uuid": "8a1dd38f-312a-47da-905c-79698fc4f27c", "name": "load_p1rlv13034_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3b7bff1-90da-4ee2-8a0f-8e291a7e8ac8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a399b34-ceb0-4ca8-ab6b-fbeb5d6f11c7"}}}}, {"uuid": "223ca125-2a2e-42c1-a0f0-1828dd36ffba", "name": "5cbc8aa5-1d48-4762-9892-454566c93f99_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.074192704000552, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.129078804753558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a6972633-51d9-4e1e-be81-d289073144bd", "name": "4f0c4078-005c-4e05-a7c1-0bc96ee69bb0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "223ca125-2a2e-42c1-a0f0-1828dd36ffba"}}}]}, {"uuid": "fb379ee7-427c-476e-ac35-a702194e4e69", "name": "load_p1rlv13034_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3b7bff1-90da-4ee2-8a0f-8e291a7e8ac8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a6972633-51d9-4e1e-be81-d289073144bd"}}}}, {"uuid": "138ba538-6925-4490-b7f9-acb50c759789", "name": "3c7fb123-b99c-46f9-9eec-1cafe1d9f2e8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8791002615066037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24190904367644575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50264ea1-2130-4ac4-8d83-06f7624bd00e", "name": "44c01c96-1d1c-4b12-a737-fa38d53e233c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "138ba538-6925-4490-b7f9-acb50c759789"}}}]}, {"uuid": "349eb58c-b111-4f6d-92c2-159ecb9b146c", "name": "load_p1rlv13035_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6d309ef-b082-4022-a265-4891cdcd6db9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50264ea1-2130-4ac4-8d83-06f7624bd00e"}}}}, {"uuid": "b87dfe47-5295-4a04-b72a-5be002a781e1", "name": "6e915124-e0ea-436f-9543-a77188bab4cd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8791002615066037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24190904367644575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2fa5a665-5deb-467b-bc9f-e71f2bfdf9cf", "name": "bee7ab42-c47c-4c2f-8de9-ccab5a61c6bf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b87dfe47-5295-4a04-b72a-5be002a781e1"}}}]}, {"uuid": "e46287b6-7827-4592-b1f2-e687e6f7c00a", "name": "load_p1rlv13035_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6d309ef-b082-4022-a265-4891cdcd6db9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2fa5a665-5deb-467b-bc9f-e71f2bfdf9cf"}}}}, {"uuid": "b1401c39-ec75-4e7a-8caa-59de8c4e3727", "name": "7ec60f8a-d974-4b77-92e3-6cbdb06326b0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.131827489381682, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6495252596209705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "99ced9d6-782f-4da9-9093-b8b75d9454c2", "name": "19e9f87e-4cc7-4702-8545-744ffab5f522", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b1401c39-ec75-4e7a-8caa-59de8c4e3727"}}}]}, {"uuid": "74249f5e-7c0c-44ef-a2be-d9cadb9b8d06", "name": "load_p1rlv13036_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23aae8f1-8b9f-4453-9643-b49ffdc80889"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "99ced9d6-782f-4da9-9093-b8b75d9454c2"}}}}, {"uuid": "bb7a935e-ef3f-4259-9dce-2efb49419534", "name": "8451fc2b-9ede-464e-80ad-cec49e4e429f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.131827489381682, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6495252596209705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5a4776db-fe9d-4c72-b386-e630b5d5e0c9", "name": "c75f3183-02be-4b10-b581-a012f3bdcff2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bb7a935e-ef3f-4259-9dce-2efb49419534"}}}]}, {"uuid": "d0d08220-f82e-4813-9e86-d7f5cb6054e5", "name": "load_p1rlv13036_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23aae8f1-8b9f-4453-9643-b49ffdc80889"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5a4776db-fe9d-4c72-b386-e630b5d5e0c9"}}}}, {"uuid": "77d82711-d253-462f-9ce5-586d5710551c", "name": "d87b062f-7549-4bee-af82-d39450b08042_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5976710782342964, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7583664749710641, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "671b0544-3d59-4a1b-8ec2-057c16dd2d81", "name": "05306373-07f2-441b-a327-a67270b22e0d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "77d82711-d253-462f-9ce5-586d5710551c"}}}]}, {"uuid": "15c35e98-5054-4b11-b7b4-e8429f0b12fc", "name": "load_p1rlv13037_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f5d04aa-74fb-4d1a-ac91-6c01a56a94b5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "671b0544-3d59-4a1b-8ec2-057c16dd2d81"}}}}, {"uuid": "f31d5dca-c798-4cd4-b33b-6ef36ff34bc7", "name": "7dbc7a03-397e-4144-b496-f0c6fa124214_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5976710782342964, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7583664749710641, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a3e03fb2-566e-4710-a10c-7991ba3eeca0", "name": "4280b610-705e-4bf3-ba2f-30e609aa9084", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f31d5dca-c798-4cd4-b33b-6ef36ff34bc7"}}}]}, {"uuid": "1cd6f0e8-61a1-4056-9be8-650d4ddfb3c8", "name": "load_p1rlv13037_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f5d04aa-74fb-4d1a-ac91-6c01a56a94b5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a3e03fb2-566e-4710-a10c-7991ba3eeca0"}}}}, {"uuid": "79a2c1dd-04cb-47c4-aea3-5ad30f4dd768", "name": "635abd80-13c7-475c-af2d-43f4c81f0b5c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3798783675992279, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6151141774255103, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "74679bbb-a484-4253-95c3-882a57fe12a8", "name": "7a58bd99-3ac7-4f56-92ae-cdd643b0c927", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "79a2c1dd-04cb-47c4-aea3-5ad30f4dd768"}}}]}, {"uuid": "5502f1c8-b1b7-4e4b-a292-e5983d56926a", "name": "load_p1rlv13038_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a8b4502-31fd-4dce-8717-9860880075b4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "74679bbb-a484-4253-95c3-882a57fe12a8"}}}}, {"uuid": "8ad46779-2f5a-4b34-9123-594b28c7eef7", "name": "5dce28a7-bf93-405d-8b27-8d86926ff647_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3798783675992279, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6151141774255103, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fe24ccb4-a072-4c0e-9c69-7397187c0cf7", "name": "4477297e-dda0-42e2-bb36-9d0b9e1a7d1a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ad46779-2f5a-4b34-9123-594b28c7eef7"}}}]}, {"uuid": "b4ade9d1-a099-4144-8c8f-1313629a488b", "name": "load_p1rlv13038_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a8b4502-31fd-4dce-8717-9860880075b4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fe24ccb4-a072-4c0e-9c69-7397187c0cf7"}}}}, {"uuid": "f0d3a250-3125-47eb-beed-cb4d47fa06b4", "name": "177b4262-69d7-456e-a722-ddb895f56358_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9179777962446224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3481400399277513, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4bbd2f71-2995-4f3a-8fa8-bbdbc13b5f7b", "name": "e4ad0457-669c-4703-8935-20a525526720", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f0d3a250-3125-47eb-beed-cb4d47fa06b4"}}}]}, {"uuid": "8016b94a-61cd-4674-9c60-0410c68b8445", "name": "load_p1rlv13039_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34d43081-e4a3-4f1b-8b90-5965458452d0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4bbd2f71-2995-4f3a-8fa8-bbdbc13b5f7b"}}}}, {"uuid": "07e8ba08-4868-403a-8a82-8ca90c974837", "name": "b8559d4c-4ddd-4d69-af4d-82e49146b816_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9179777962446224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3481400399277513, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4d0f1690-75ce-4f79-9841-9acb4c42984c", "name": "5287314b-d1e0-4ade-b0b3-387b6329da2c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "07e8ba08-4868-403a-8a82-8ca90c974837"}}}]}, {"uuid": "b9f95b3b-f26e-4c6a-a080-a497e15d7e02", "name": "load_p1rlv13039_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34d43081-e4a3-4f1b-8b90-5965458452d0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4d0f1690-75ce-4f79-9841-9acb4c42984c"}}}}, {"uuid": "e29843ac-90b9-437c-9117-ccf066515291", "name": "29e3febd-4892-42b4-b287-c9ebfb418d08_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4464370236076721, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16599396793014964, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "03f4d81e-7c78-4db0-89f5-bee053df019a", "name": "d4430213-5d8e-4f92-af83-09a386b39a7e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e29843ac-90b9-437c-9117-ccf066515291"}}}]}, {"uuid": "c9b00953-9433-444e-a5c9-287baab06620", "name": "load_p1rlv13040_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6839f65-9d3b-4bd6-89a4-0c8feb33e98a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "03f4d81e-7c78-4db0-89f5-bee053df019a"}}}}, {"uuid": "2e0477a3-1ea7-4d91-81c7-3e83d4dea658", "name": "ecf11542-81c2-4406-a311-e724aa04cf7a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4464370236076721, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16599396793014964, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ddcc766b-ec42-4d26-bd83-7ddc9efec038", "name": "8083a4d1-79d3-4022-9268-102584301916", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2e0477a3-1ea7-4d91-81c7-3e83d4dea658"}}}]}, {"uuid": "09a05117-9020-4a21-8ab8-0ef14c99c774", "name": "load_p1rlv13040_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6839f65-9d3b-4bd6-89a4-0c8feb33e98a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ddcc766b-ec42-4d26-bd83-7ddc9efec038"}}}}, {"uuid": "9fd53137-bf5a-4f5f-a0b4-8276d87bb04e", "name": "6c17db69-bff2-4e56-a3c1-bb3723cd6918_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6434260893942235, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2588956175598443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3782e5b3-e7f7-4d7f-b4b4-58875e227199", "name": "f2e69ca8-aaf9-43be-9bee-272320ab0e80", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9fd53137-bf5a-4f5f-a0b4-8276d87bb04e"}}}]}, {"uuid": "1e04bc67-8ff5-44ca-8784-51571cb550f5", "name": "load_p1rlv13041_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60144ce1-d4d6-4725-b543-f881894356a5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3782e5b3-e7f7-4d7f-b4b4-58875e227199"}}}}, {"uuid": "30335b57-8e08-4154-960d-cdb9c5ede14d", "name": "6231824f-1b85-4d24-800d-f11202944c11_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6434260893942235, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2588956175598443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "119a9724-a20e-416d-809e-b714471622b9", "name": "184a31ea-7142-4290-9059-ff71e29618bd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "30335b57-8e08-4154-960d-cdb9c5ede14d"}}}]}, {"uuid": "d020a635-aab4-4f6b-83b6-a53650efb072", "name": "load_p1rlv13041_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60144ce1-d4d6-4725-b543-f881894356a5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "119a9724-a20e-416d-809e-b714471622b9"}}}}, {"uuid": "55db8cce-9446-48f3-8af9-62589b3bd742", "name": "b428e6d6-918d-4b4d-971d-7391125b8f9b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4148353854888571, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6393114443430603, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "294d20fe-cf8c-46f0-9f89-0657ecce2434", "name": "deaccebf-96cd-40dd-b573-7ca8f71d8aa1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "55db8cce-9446-48f3-8af9-62589b3bd742"}}}]}, {"uuid": "d794cf69-32cb-405e-aea3-c90086351290", "name": "load_p1rlv13042_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "296cd07e-c2e3-4031-abad-9c870a65105d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "294d20fe-cf8c-46f0-9f89-0657ecce2434"}}}}, {"uuid": "9eb257c7-77e7-41ba-b202-3ff32c0bae0f", "name": "32b13cdb-a6a7-4fa4-9149-82f44136ffe0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4148353854888571, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6393114443430603, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bd71a0f0-6c1d-48ed-bf4a-8de6a137936e", "name": "8f98108c-29bd-4c2f-ad46-00c13335eece", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9eb257c7-77e7-41ba-b202-3ff32c0bae0f"}}}]}, {"uuid": "3d035aed-8608-46c0-983e-7d889e4949f9", "name": "load_p1rlv13042_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "296cd07e-c2e3-4031-abad-9c870a65105d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bd71a0f0-6c1d-48ed-bf4a-8de6a137936e"}}}}, {"uuid": "425e2de3-13e4-4801-a064-4d6ab2e349ce", "name": "2aafb20a-ab3e-4270-8650-395ae93416dd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.478593979285423, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7308840963144931, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "291002f8-5c77-41b0-b8e0-60cd4dbfc1da", "name": "e96ce69e-4a0b-451e-beb7-464af7b99a7f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "425e2de3-13e4-4801-a064-4d6ab2e349ce"}}}]}, {"uuid": "f7547184-7196-4c0c-9432-e18539ec7017", "name": "load_p1rlv13513_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3243ca2f-a97e-4fbc-981d-85eded2e5e6b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "291002f8-5c77-41b0-b8e0-60cd4dbfc1da"}}}}, {"uuid": "fed2bcf4-ae62-4152-aa92-ec9cbf205825", "name": "f582a945-a569-495f-b213-31a28a011ac9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.478593979285423, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7308840963144931, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f12ac523-0ead-4cbf-969c-b26ceaaeec58", "name": "eb431eed-b218-4601-9fa7-f4a8dabafcff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fed2bcf4-ae62-4152-aa92-ec9cbf205825"}}}]}, {"uuid": "737befe8-c05e-4ae8-baf6-f2e2a1d20f28", "name": "load_p1rlv13513_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3243ca2f-a97e-4fbc-981d-85eded2e5e6b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f12ac523-0ead-4cbf-969c-b26ceaaeec58"}}}}, {"uuid": "1a5b8ef6-4d4b-4207-aaae-0b8a6562ae2c", "name": "e127eac9-8755-4774-a29d-89f9e6b418a0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.516258392707745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.82351986644914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "03330f10-9cb3-42e2-aef8-e02084fc5dec", "name": "a8790ecc-0157-4088-82d4-7aa10c681ebb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1a5b8ef6-4d4b-4207-aaae-0b8a6562ae2c"}}}]}, {"uuid": "059c3995-844d-453c-932d-52647f7dbc4c", "name": "load_p1rlv13789_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47a7519a-b550-41e6-99e3-c2115db425fe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "03330f10-9cb3-42e2-aef8-e02084fc5dec"}}}}, {"uuid": "2e22c9e7-f048-46f8-bc69-5861cfd05527", "name": "8c2a521a-38cb-4686-8fa9-386999634546_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.516258392707745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.82351986644914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eae585db-5e8d-4d76-8203-27d0420f79b4", "name": "188cd438-df8d-4b24-b92d-fddfbb0a2ebe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2e22c9e7-f048-46f8-bc69-5861cfd05527"}}}]}, {"uuid": "5cf01015-ea31-4da1-939a-778efe5c2762", "name": "load_p1rlv13789_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47a7519a-b550-41e6-99e3-c2115db425fe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eae585db-5e8d-4d76-8203-27d0420f79b4"}}}}, {"uuid": "15995836-e2ba-4cf9-b118-fff27f395444", "name": "a6f8ebb6-0854-4d92-9356-401305b2a257_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3786182488338723, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5359363058124609, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6151c915-f4c7-4240-b24d-ee4967125fff", "name": "08169670-c1b9-4102-9b44-fc13d2303d0c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "15995836-e2ba-4cf9-b118-fff27f395444"}}}]}, {"uuid": "4e713549-1fcf-420c-ba99-1a57feebc8e5", "name": "load_p1rlv13791_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "251f270f-4238-4fe6-8ab3-f884fca7a42d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6151c915-f4c7-4240-b24d-ee4967125fff"}}}}, {"uuid": "7dfb398c-2767-42a5-a503-e4c1a92dab37", "name": "787f56e7-2686-4704-aafa-30bc043d4c7d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3786182488338723, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5359363058124609, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "01d1aabe-0a01-4e59-a48f-7c981a2fdc1a", "name": "22519096-b6e1-40e2-975d-736497e787ed", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7dfb398c-2767-42a5-a503-e4c1a92dab37"}}}]}, {"uuid": "db355cce-248a-4b61-815d-b564ae9f0424", "name": "load_p1rlv13791_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "251f270f-4238-4fe6-8ab3-f884fca7a42d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "01d1aabe-0a01-4e59-a48f-7c981a2fdc1a"}}}}, {"uuid": "5b2c074c-c20e-4eab-b9a8-e92b48974001", "name": "8fde2c8d-0b7d-43c0-b5e3-9724c9e6f07c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4950137537296666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31506625700854357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5c88bd25-3fea-4b53-a5c3-29d534c2286e", "name": "86a0e8fc-47a8-451c-b70d-2cb2c944eb6e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b2c074c-c20e-4eab-b9a8-e92b48974001"}}}]}, {"uuid": "2bb93d01-77c6-4fb0-b5b0-918cc6184ea8", "name": "load_p1rlv13796_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94ac9254-cdbf-4864-b22b-bcfb0a827700"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5c88bd25-3fea-4b53-a5c3-29d534c2286e"}}}}, {"uuid": "eb63e254-b796-476a-afba-e8ebb47b74e4", "name": "cf5e3c94-b0f7-462e-a355-b258ae53f695_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4950137537296666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31506625700854357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "23da9e2b-d468-4008-b47f-d63d8c87dadb", "name": "6a1fe7ff-ccbd-46ac-b9ad-285f127c3344", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eb63e254-b796-476a-afba-e8ebb47b74e4"}}}]}, {"uuid": "2f75fc92-6b34-4785-8154-8f0b31b77142", "name": "load_p1rlv13796_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94ac9254-cdbf-4864-b22b-bcfb0a827700"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "23da9e2b-d468-4008-b47f-d63d8c87dadb"}}}}, {"uuid": "62825484-a85f-4497-9f3f-aa09f9016fe1", "name": "52fad3e9-45c9-4056-a73b-cb0e42e846c1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.008167500419157, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.871384812064858, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "40ad2075-2f27-43f9-bf26-24398179c740", "name": "15638478-3799-4f8d-a195-0cf7ad60607a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "62825484-a85f-4497-9f3f-aa09f9016fe1"}}}]}, {"uuid": "8e3b48bc-f743-4918-a2a8-d5c73997b5a5", "name": "load_p1rlv13801_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "accec892-a236-462d-b714-1178393ec992"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "40ad2075-2f27-43f9-bf26-24398179c740"}}}}, {"uuid": "da810e7f-f506-45e9-913d-f97a58abd11e", "name": "648f7673-2b7c-4917-9c63-f95e75196436_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.008167500419157, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.871384812064858, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1f8ea155-e6d1-4317-8ea6-a50f177cd91d", "name": "6e917f1f-4044-42e1-adfd-a0279c5d3d2d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "da810e7f-f506-45e9-913d-f97a58abd11e"}}}]}, {"uuid": "a0320d1d-20ae-462f-9746-521cd612a5bd", "name": "load_p1rlv13801_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "accec892-a236-462d-b714-1178393ec992"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1f8ea155-e6d1-4317-8ea6-a50f177cd91d"}}}}, {"uuid": "888affa1-c032-49bf-b439-d454732e868e", "name": "aa1d1c01-f032-40a4-85be-478812f1eec9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7055277650263714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24030088917661724, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f3390525-aa36-4b5e-b5c7-05b031722646", "name": "ac90927c-2c18-439c-9388-1849753638b9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "888affa1-c032-49bf-b439-d454732e868e"}}}]}, {"uuid": "0f26d234-dc12-4b26-9669-c0cc9f06d569", "name": "load_p1rlv13807_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c26fba44-3b81-47de-81e6-522f2daf0534"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f3390525-aa36-4b5e-b5c7-05b031722646"}}}}, {"uuid": "e816eb48-5381-4aa3-8477-15717e4343b5", "name": "3f3c2bee-1196-4b7f-aa9a-6b7f6163e03a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7055277650263714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24030088917661724, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "67b6d902-8b82-47cf-a989-f252d66071a4", "name": "4f177047-2b91-4fcc-aee1-b7321b7be182", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e816eb48-5381-4aa3-8477-15717e4343b5"}}}]}, {"uuid": "6d8a4cc7-ad2d-4b8e-9bdf-c6ca602aad0c", "name": "load_p1rlv13807_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c26fba44-3b81-47de-81e6-522f2daf0534"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "67b6d902-8b82-47cf-a989-f252d66071a4"}}}}, {"uuid": "d1cf8902-36ff-4259-8e06-9c26e6496790", "name": "4d637426-9411-4538-9c9c-90c7616f7121_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5041010955030301, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21577690333785765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4459f193-4f92-46a4-8eed-add2c2837094", "name": "95fb1d20-7bb6-49df-901a-9410ab8b79e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d1cf8902-36ff-4259-8e06-9c26e6496790"}}}]}, {"uuid": "3e004b64-3af9-48f6-9dfd-fc8b13172d45", "name": "load_p1rlv13808_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c795ac7-3b49-4158-996d-2fb1f0337847"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4459f193-4f92-46a4-8eed-add2c2837094"}}}}, {"uuid": "2f4c2dc2-6bdb-4037-90cb-691a2702b98b", "name": "958bc998-f198-4634-9716-9c72eefb2a1c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5041010955030301, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21577690333785765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "27270979-b92b-4d35-af3a-2c0e04df552b", "name": "0c08438e-daba-4da3-a5dc-db54fa184471", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2f4c2dc2-6bdb-4037-90cb-691a2702b98b"}}}]}, {"uuid": "74ab9452-4a60-4e6f-8072-464d74ee30df", "name": "load_p1rlv13808_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c795ac7-3b49-4158-996d-2fb1f0337847"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "27270979-b92b-4d35-af3a-2c0e04df552b"}}}}, {"uuid": "09eac509-8dac-41fe-9bce-64d8745425df", "name": "7dd53474-539f-4945-ac4c-c735c42112a5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0716753053645807, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8046017922971841, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "595de68a-b010-43ba-b21e-cc78f49bf48c", "name": "f02bea0f-dbc3-4422-a398-93888ea0def0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "09eac509-8dac-41fe-9bce-64d8745425df"}}}]}, {"uuid": "5c7db3cf-10d4-4267-8217-45a53afc7161", "name": "load_p1rlv13809_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "687996da-ab03-4544-b0d9-b79b8ac88e95"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "595de68a-b010-43ba-b21e-cc78f49bf48c"}}}}, {"uuid": "e5a9e2ec-ffef-4651-b51a-9f5316c82fb3", "name": "d7ece7d1-ce61-48ea-9df6-aa24014abecc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0716753053645807, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8046017922971841, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "efe80323-ab9b-4e01-815f-7fd0ce6c61df", "name": "92358e67-308f-4f32-b27a-e88559370266", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e5a9e2ec-ffef-4651-b51a-9f5316c82fb3"}}}]}, {"uuid": "0f2cf445-d144-43b5-80e0-38fd27f20829", "name": "load_p1rlv13809_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "687996da-ab03-4544-b0d9-b79b8ac88e95"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "efe80323-ab9b-4e01-815f-7fd0ce6c61df"}}}}, {"uuid": "764a156c-e82c-4978-9206-f52ce77f1f99", "name": "c1836a03-add8-4694-8d66-c2a6ed431151_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2437684685157903, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09956111056866535, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ae3347f6-7775-4433-814b-7ba9513e963e", "name": "bd38cf53-e217-4b92-a4c4-d1ffe15199df", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "764a156c-e82c-4978-9206-f52ce77f1f99"}}}]}, {"uuid": "55eed416-e9d9-4d58-8026-22b2f3f7cfe3", "name": "load_p1rlv13810_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab29ca66-d59b-4aa6-b5f6-165add0bc331"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ae3347f6-7775-4433-814b-7ba9513e963e"}}}}, {"uuid": "5cb79924-30c9-43e2-9a96-729fd0ac694c", "name": "3debea35-c388-41e2-83e2-aa90977b6cc3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2437684685157903, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09956111056866535, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2e0910b7-f02c-4d0e-bf15-f0b81921172f", "name": "f99681c6-3e7c-4c69-85c3-db72b795048f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5cb79924-30c9-43e2-9a96-729fd0ac694c"}}}]}, {"uuid": "8c2da7f0-f23d-49e5-a56f-820d68cb01a9", "name": "load_p1rlv13810_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab29ca66-d59b-4aa6-b5f6-165add0bc331"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2e0910b7-f02c-4d0e-bf15-f0b81921172f"}}}}, {"uuid": "8982f43c-2ab5-484c-91cd-8e23d4654b47", "name": "072f3713-115a-432e-b689-83fa9f6ad36d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.291842017688742, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7877197601951852, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0e13e8a7-69f7-4384-b6c2-6f9ab0821da4", "name": "a275ccd5-d06c-427c-b582-d3fa7d408111", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8982f43c-2ab5-484c-91cd-8e23d4654b47"}}}]}, {"uuid": "77fbe0a1-4002-4304-b6e3-b6284061bd2f", "name": "load_p1rlv13814_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028d5ead-7c34-400b-bcc1-c4d706c965d3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0e13e8a7-69f7-4384-b6c2-6f9ab0821da4"}}}}, {"uuid": "9c01f881-0f25-4d6f-a0dd-993098bd49f3", "name": "f2d86489-1f92-4a87-bfff-a752fdc6953b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.291842017688742, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7877197601951852, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d84a97b2-613d-4893-b775-76dcb6d72baf", "name": "beb70e77-2905-4532-b661-ae7947ab1dd9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9c01f881-0f25-4d6f-a0dd-993098bd49f3"}}}]}, {"uuid": "725fc8ff-fe31-4c43-a721-a77c74959288", "name": "load_p1rlv13814_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028d5ead-7c34-400b-bcc1-c4d706c965d3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d84a97b2-613d-4893-b775-76dcb6d72baf"}}}}, {"uuid": "9485e0ab-76b3-4249-95c6-c9694fbcc55f", "name": "186fb67b-61b4-4e51-85e1-ea65bdfd5178_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5478654763148745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5646840796232575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82a2547d-e285-4e42-9a0d-ba17743e95e5", "name": "c4052cf7-690b-460a-9695-67409665f911", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9485e0ab-76b3-4249-95c6-c9694fbcc55f"}}}]}, {"uuid": "61cacffc-8e4f-446d-9a8a-931f9727a422", "name": "load_p1rlv13815_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99957459-46a6-4b2b-9813-69b11ca7dad1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "82a2547d-e285-4e42-9a0d-ba17743e95e5"}}}}, {"uuid": "66b8279c-9e1c-45f4-b507-e46cf979f5c6", "name": "191437de-ee79-45c6-be63-1bbce4377cfc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5478654763148745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5646840796232575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6ef4d2cf-ba8f-4ed5-8ce4-e3056b1156af", "name": "c7fff845-744f-4630-aa26-cd67a5961399", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "66b8279c-9e1c-45f4-b507-e46cf979f5c6"}}}]}, {"uuid": "76a08ec6-32a3-435c-9c52-2118ff199523", "name": "load_p1rlv13815_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99957459-46a6-4b2b-9813-69b11ca7dad1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6ef4d2cf-ba8f-4ed5-8ce4-e3056b1156af"}}}}, {"uuid": "a17c41d6-24e9-4b26-b9f9-de67964bb309", "name": "874e3fbd-6b4d-407a-8383-51ddc0d9aef7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0085854932437286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7150296414254909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "81850b27-a9b8-4fab-b10e-81a89ac0bc87", "name": "fc960aa0-6058-4889-b9e8-5a07b2878577", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a17c41d6-24e9-4b26-b9f9-de67964bb309"}}}]}, {"uuid": "f8444c20-8eea-40ac-a488-93a9711e5ff0", "name": "load_p1rlv13817_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e96bcc5b-07c5-4289-aec4-0224395c5e8a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "81850b27-a9b8-4fab-b10e-81a89ac0bc87"}}}}, {"uuid": "d54c2be7-a14b-4aef-8853-4acd41e72c47", "name": "3c0522c5-f6f6-4b47-a464-522778742137_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0085854932437286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7150296414254909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "12e364e5-acfd-4e1d-89f6-21c9acd3d848", "name": "d620051e-a9a4-445e-aa26-8eca2cc48ec2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d54c2be7-a14b-4aef-8853-4acd41e72c47"}}}]}, {"uuid": "010ca500-2acf-4ce6-a039-674b272f9de8", "name": "load_p1rlv13817_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e96bcc5b-07c5-4289-aec4-0224395c5e8a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "12e364e5-acfd-4e1d-89f6-21c9acd3d848"}}}}, {"uuid": "4ed34c37-e2e9-4a65-a903-8a7caf11552c", "name": "78d7d066-06b1-4597-8e7d-fbf0e4036139_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1381537134701794, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42848704523913217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c0b7b5ac-4a0b-49c2-92c7-27cadd156772", "name": "aebf1b77-f7cf-43a9-a950-21464c55fb9e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4ed34c37-e2e9-4a65-a903-8a7caf11552c"}}}]}, {"uuid": "a8a6ea27-b4a4-4d06-8c4f-af8f1127daad", "name": "load_p1rlv13819_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36c12a74-a2ca-439a-a69f-308dd5cb1207"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c0b7b5ac-4a0b-49c2-92c7-27cadd156772"}}}}, {"uuid": "781fe3f1-6b6c-48b9-abd9-77d5b7369aae", "name": "5f1443a2-975b-4cb0-86c4-0b677d3a55db_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1381537134701794, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42848704523913217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "35ede9f1-60a6-4d8d-9701-723de6433418", "name": "efef0562-da88-4e42-aade-749922d559fa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "781fe3f1-6b6c-48b9-abd9-77d5b7369aae"}}}]}, {"uuid": "109422e2-02b7-4e4c-a09f-06afab81a341", "name": "load_p1rlv13819_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36c12a74-a2ca-439a-a69f-308dd5cb1207"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "35ede9f1-60a6-4d8d-9701-723de6433418"}}}}, {"uuid": "66d4d596-e4c7-4a54-a4e6-38df808f0693", "name": "14e258f3-02bd-4e24-95a2-41a1a66bfdb7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.3612796720379805, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.3972907909814523, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a31f4fb0-d83d-4ad1-86a9-4cfdf5a4bee9", "name": "9b2c0e73-1ff0-4035-bd34-92cd7d49c9be", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "66d4d596-e4c7-4a54-a4e6-38df808f0693"}}}]}, {"uuid": "85c9ad07-5dc3-47c3-aa58-1945480e5aff", "name": "load_p1rlv13820_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a2caa70b-9143-4676-834b-bfc7cb41330c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a31f4fb0-d83d-4ad1-86a9-4cfdf5a4bee9"}}}}, {"uuid": "b927f7b1-4142-4df3-a0fa-95a333a7982f", "name": "2a448f2a-f40c-4c5d-bd9f-5e1dc505e62d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.3612796720379805, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.3972907909814523, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bc7e8ec9-7648-41d1-8858-e4c8ddaaef33", "name": "98b412f3-26ab-4cfa-a65f-55021acba615", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b927f7b1-4142-4df3-a0fa-95a333a7982f"}}}]}, {"uuid": "d09ba371-5421-4487-90ee-5e8bfd642999", "name": "load_p1rlv13820_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a2caa70b-9143-4676-834b-bfc7cb41330c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bc7e8ec9-7648-41d1-8858-e4c8ddaaef33"}}}}, {"uuid": "ad98ac11-5d4c-4742-b631-47f8b8ad5445", "name": "ab8854ef-b22e-4714-8819-41beee60bb75_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.635130525488038, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.332876746135676, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a8dbac4e-81f6-40fa-8b95-8d36357946af", "name": "4d40fbdc-7093-474b-be43-a3bb70b4d5ff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ad98ac11-5d4c-4742-b631-47f8b8ad5445"}}}]}, {"uuid": "d501dc5e-ac3c-457d-9bc2-ea5a144144eb", "name": "load_p1rlv13821_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66e6c732-919a-4851-9f76-5580ea71669d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a8dbac4e-81f6-40fa-8b95-8d36357946af"}}}}, {"uuid": "8f0e7ca1-035f-45eb-b40d-b347ef767d4f", "name": "ca440c4c-f25c-4309-98c9-edf583c1ec98_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.635130525488038, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.332876746135676, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "57e80d64-eb9a-4869-acfa-665c994e1148", "name": "8ae6d28a-801a-45b2-8390-e0422e4f9124", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8f0e7ca1-035f-45eb-b40d-b347ef767d4f"}}}]}, {"uuid": "a78a4b78-fc95-4288-bc8f-85602712d6c7", "name": "load_p1rlv13821_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66e6c732-919a-4851-9f76-5580ea71669d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "57e80d64-eb9a-4869-acfa-665c994e1148"}}}}, {"uuid": "355253ea-407d-4eb0-9b8d-c609e3b8b8cc", "name": "6ebb2d5e-69fc-474d-bda3-d3b44a463d0c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7812856221781264, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.29493523962554685, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ff2e9217-8807-434d-a450-744efe345e72", "name": "3752c325-d5c2-4d40-8e38-7b04fc71177a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "355253ea-407d-4eb0-9b8d-c609e3b8b8cc"}}}]}, {"uuid": "68efcac0-34fe-4dd9-a0e2-fe0c3d757d94", "name": "load_p1rlv13822_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ade9991-a857-4619-8094-c18f824aaeb9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ff2e9217-8807-434d-a450-744efe345e72"}}}}, {"uuid": "6bd0f62f-8edf-4810-99be-e798cac24cf2", "name": "356dfa36-fd2a-4a57-8e5d-1a9549308602_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7812856221781264, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.29493523962554685, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6407febc-5c2c-4ba9-803c-40af9378c220", "name": "32c9cd48-906e-4915-b516-d48f6bb09d2c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6bd0f62f-8edf-4810-99be-e798cac24cf2"}}}]}, {"uuid": "4da4f5d5-66ee-4fcb-aea2-ce75b8f24a11", "name": "load_p1rlv13822_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ade9991-a857-4619-8094-c18f824aaeb9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6407febc-5c2c-4ba9-803c-40af9378c220"}}}}, {"uuid": "46b7186f-23aa-404f-89fe-b1da22b8988b", "name": "71a40a7d-0b07-4707-9fc8-7453aa248bbb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1222862909492073, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34523553920221683, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c03ecb1d-7a8d-432a-87f1-649a7a2c0bd8", "name": "9143989a-51bb-4e7f-bbaf-2e6f00feef4c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "46b7186f-23aa-404f-89fe-b1da22b8988b"}}}]}, {"uuid": "b18c5017-b58a-4d8e-99df-186b1dba584a", "name": "load_p1rlv13823_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0ca6e47-afec-4d61-885a-e38176b32444"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c03ecb1d-7a8d-432a-87f1-649a7a2c0bd8"}}}}, {"uuid": "bc9b1700-bb49-4cb1-ba5d-5f80b5313fde", "name": "19de82c2-7a92-46ca-bc78-b9aa550e0efc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1222862909492073, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34523553920221683, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "481ac917-3cd4-4104-bab6-aad3b2b02a90", "name": "1612e353-bc27-4924-95ca-d05df4a50023", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bc9b1700-bb49-4cb1-ba5d-5f80b5313fde"}}}]}, {"uuid": "96ad3f28-9350-4e7f-abbc-430e1bb63746", "name": "load_p1rlv13823_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0ca6e47-afec-4d61-885a-e38176b32444"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "481ac917-3cd4-4104-bab6-aad3b2b02a90"}}}}, {"uuid": "79f3753a-7149-4157-b5e4-68982efaa8ca", "name": "093cd540-9bbc-4ee5-a1e0-2e2ef4a34478_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0669054080609572, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7994840804155045, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f2b10606-cf40-4f5e-bb6b-1183f05e041e", "name": "acb548ef-de03-45bf-bf02-d36ee7faa744", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "79f3753a-7149-4157-b5e4-68982efaa8ca"}}}]}, {"uuid": "9c321716-f7ca-445e-b012-ab6f30c94193", "name": "load_p1rlv15585_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17bf6d8f-8215-4294-b921-cc3e34476f1e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f2b10606-cf40-4f5e-bb6b-1183f05e041e"}}}}, {"uuid": "e0082e7d-626d-4758-b35b-36b85a8bff3c", "name": "35e9eec9-3f85-4855-bfa4-52cf1d9cba4e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0669054080609572, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7994840804155045, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1edba1d9-3282-4395-a1ac-8fd917612c27", "name": "d0a1ea2f-1355-4c4d-878f-841f1e375af0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e0082e7d-626d-4758-b35b-36b85a8bff3c"}}}]}, {"uuid": "1cc5b71c-3d4d-4387-9b29-4375835ef133", "name": "load_p1rlv15585_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17bf6d8f-8215-4294-b921-cc3e34476f1e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1edba1d9-3282-4395-a1ac-8fd917612c27"}}}}, {"uuid": "54f40cb1-f555-4f22-9b86-3ed586a0c349", "name": "c29e80eb-35b5-42ba-9bbe-89cbf4d903da_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5604078463831266, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5882122505209306, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "059e1513-1fe8-44d2-9898-82d08b870b03", "name": "9b67a0dd-e06b-428b-bdf8-4ccfb9e0750b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "54f40cb1-f555-4f22-9b86-3ed586a0c349"}}}]}, {"uuid": "73b6699e-ca8b-43e4-b03e-082e1cc0e819", "name": "load_p1rlv15590_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef2a4478-4644-4bd3-9548-ab1d0be338b5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "059e1513-1fe8-44d2-9898-82d08b870b03"}}}}, {"uuid": "0e336d83-0a40-46ee-b0c8-a82812cf81a4", "name": "43ad8f4c-662d-4fb5-a5f9-a48dbaa271a7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5604078463831266, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5882122505209306, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2461bc70-0a3e-46b4-ad45-4297c1165017", "name": "4bf42159-d677-40ea-8cc5-b5591969ab5d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0e336d83-0a40-46ee-b0c8-a82812cf81a4"}}}]}, {"uuid": "7e04a4d6-9633-4b85-8c34-9d443e029fd6", "name": "load_p1rlv15590_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef2a4478-4644-4bd3-9548-ab1d0be338b5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2461bc70-0a3e-46b4-ad45-4297c1165017"}}}}, {"uuid": "f944fca3-773c-4d7f-8b9c-9c768d5194b2", "name": "9a7d04aa-5710-4fb1-bafb-40d7ed8d7695_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.478593979285423, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7308840963144931, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "17274469-c61a-4e5b-9160-1467f85cf8cf", "name": "931f85c8-2769-4c0e-9348-bb5827062179", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f944fca3-773c-4d7f-8b9c-9c768d5194b2"}}}]}, {"uuid": "a5d49acc-5c50-4480-842c-23e9d28d87bf", "name": "load_p1rlv15591_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c04c9ad1-4277-47de-9cec-9ce86e17b4f1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "17274469-c61a-4e5b-9160-1467f85cf8cf"}}}}, {"uuid": "0a49d7eb-c234-4ada-b568-908ac6cb8e4a", "name": "666b1c83-9b0c-4428-a813-b474316ec8f4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.478593979285423, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7308840963144931, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4148c82d-646b-4921-bc7a-6c5bf7f63ec7", "name": "c7b85c79-340b-4ef3-9ed6-191a807611d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0a49d7eb-c234-4ada-b568-908ac6cb8e4a"}}}]}, {"uuid": "ac304791-72f7-4e03-8c61-3aba5baa1c72", "name": "load_p1rlv15591_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c04c9ad1-4277-47de-9cec-9ce86e17b4f1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4148c82d-646b-4921-bc7a-6c5bf7f63ec7"}}}}, {"uuid": "d31de800-7b5e-4b79-8a91-b2ccf0116ef6", "name": "e1eb7567-068e-4f7f-9e16-f511bd93e9f6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.948793644259809, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2896354077041818, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2975b96e-edfa-4ad7-84f0-03367cdabd07", "name": "5e49d6ea-6260-48be-91dd-179c0bc5b5b4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d31de800-7b5e-4b79-8a91-b2ccf0116ef6"}}}]}, {"uuid": "3a9ac693-9be6-498c-ac0d-72e6efaca5cf", "name": "load_p1rlv15595_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "629e2259-2a59-4b20-b8bf-7b3b2c4a48f9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2975b96e-edfa-4ad7-84f0-03367cdabd07"}}}}, {"uuid": "ee77396d-e109-43f4-9c40-6bf91f21ab36", "name": "261e2ad9-5239-44cc-8678-56fd57346b98_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.948793644259809, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2896354077041818, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eeb2ed11-f664-42aa-9324-d0f09b516145", "name": "b870489c-6cb3-4057-80e7-9cd9924ce7b2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ee77396d-e109-43f4-9c40-6bf91f21ab36"}}}]}, {"uuid": "176c85cb-d0d6-4c48-b671-648e88751c24", "name": "load_p1rlv15595_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "629e2259-2a59-4b20-b8bf-7b3b2c4a48f9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eeb2ed11-f664-42aa-9324-d0f09b516145"}}}}, {"uuid": "a0cb21e7-4b27-494e-bb3c-081400c00bc8", "name": "7667dd6b-9cfc-4f76-a0e9-130988b27064_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6211116916449642, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3778136238343289, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "71b9d2b3-acfd-4691-9f5f-adf773dd27d8", "name": "f26b0db5-6978-4f0a-a69e-fc122b3225bb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a0cb21e7-4b27-494e-bb3c-081400c00bc8"}}}]}, {"uuid": "bf2cc4c4-abae-4bad-9ca5-5ea2c5f8bbfc", "name": "load_p1rlv15598_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "af6b7d1b-896f-44ac-8038-748c74507253"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "71b9d2b3-acfd-4691-9f5f-adf773dd27d8"}}}}, {"uuid": "81dfd6e0-dbbb-41cf-81aa-9fb817150959", "name": "8b6a8b1c-53fd-4091-9649-2bfb2059685f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6211116916449642, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3778136238343289, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10db06a2-89ef-4e34-9cbb-f016a6dc8746", "name": "60ca488e-a6f0-43aa-9158-5c4134a82e18", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "81dfd6e0-dbbb-41cf-81aa-9fb817150959"}}}]}, {"uuid": "ab44ad34-bc95-4072-8e13-b0f8a2f34e93", "name": "load_p1rlv15598_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "af6b7d1b-896f-44ac-8038-748c74507253"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10db06a2-89ef-4e34-9cbb-f016a6dc8746"}}}}, {"uuid": "de0aecc7-b36d-4357-a63e-d9785ef9bd9e", "name": "e8956775-6849-4664-a683-f47391afb338_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6626119076444468, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.30654437548368263, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "be09f5f7-fed8-43b1-b26d-c8aec95e842a", "name": "84b3e339-af7c-41c6-b51d-3c1a69a7ecf2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "de0aecc7-b36d-4357-a63e-d9785ef9bd9e"}}}]}, {"uuid": "62789cd6-098e-4f7b-8814-72c8eb1034f7", "name": "load_p1rlv15599_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ae1bbf1-459f-4346-b525-393b7d1dc958"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "be09f5f7-fed8-43b1-b26d-c8aec95e842a"}}}}, {"uuid": "8f1f6184-fcb4-4f3a-8e3f-f9f39682703d", "name": "a0dec14d-ea6f-4bfe-8b30-760d5443cf0a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6626119076444468, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.30654437548368263, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "01885877-0367-499f-83f1-52c8a24fec2e", "name": "ebec3fea-a57f-42a2-ab97-b2a72764c4a9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8f1f6184-fcb4-4f3a-8e3f-f9f39682703d"}}}]}, {"uuid": "ee2fb437-7c18-43e0-a778-72bbb4ecaf9d", "name": "load_p1rlv15599_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ae1bbf1-459f-4346-b525-393b7d1dc958"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "01885877-0367-499f-83f1-52c8a24fec2e"}}}}, {"uuid": "e56b29a0-5f6f-4023-90d3-cfe2d5ef010b", "name": "168abaa0-2fb2-4799-a684-581c86f41a4f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5348201699646123, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21241824123648728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b5869fd3-257a-473f-b5d2-282d0b26d37c", "name": "40231832-f936-4a1e-8d34-f03562bbd8aa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e56b29a0-5f6f-4023-90d3-cfe2d5ef010b"}}}]}, {"uuid": "5c5f9ae0-221c-48b9-86c2-5f669de204a3", "name": "load_p1rlv15604_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95b45d46-b7e7-46e2-98d9-5034e2fa0a17"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b5869fd3-257a-473f-b5d2-282d0b26d37c"}}}}, {"uuid": "87de1d2f-cb99-4681-b480-a5253cd1986a", "name": "0ee55c44-0e48-4ead-8915-bd8a7ece68c4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5348201699646123, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21241824123648728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "524946ab-d09d-4447-8882-4767d74df004", "name": "a25383b2-0b5e-4385-a110-4074e5c8c5b4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "87de1d2f-cb99-4681-b480-a5253cd1986a"}}}]}, {"uuid": "3fee4c6e-4a64-4574-bd57-4bfcba0420d2", "name": "load_p1rlv15604_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95b45d46-b7e7-46e2-98d9-5034e2fa0a17"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "524946ab-d09d-4447-8882-4767d74df004"}}}}, {"uuid": "662ce46f-3407-471f-a2d1-7adef310daae", "name": "b17569db-16f1-46a4-82ef-66575d501701_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7411160800233395, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1601349573814363, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bfcb1024-72a9-490c-8f55-ccb820aca246", "name": "0d318d79-dcc9-40fd-a6ea-08c8a1ae04be", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "662ce46f-3407-471f-a2d1-7adef310daae"}}}]}, {"uuid": "cb8b01f1-db5f-4676-8d79-e4ccbf10fae9", "name": "load_p1rlv15605_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcbee2ff-bf73-4834-bc3c-46fa0cfcad7c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bfcb1024-72a9-490c-8f55-ccb820aca246"}}}}, {"uuid": "205aab40-1007-48e6-83a7-4510a1f97591", "name": "8175f2e1-ebdb-424a-a3c2-2caf2256e5fc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7411160800233395, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1601349573814363, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1dedfe32-2b65-4f1a-a054-b0de2a8836b9", "name": "1a392444-0d33-46c5-8e8d-cbd0f3964e7c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "205aab40-1007-48e6-83a7-4510a1f97591"}}}]}, {"uuid": "3864a69d-0240-4a2a-83cd-4d7e71841b86", "name": "load_p1rlv15605_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcbee2ff-bf73-4834-bc3c-46fa0cfcad7c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1dedfe32-2b65-4f1a-a054-b0de2a8836b9"}}}}, {"uuid": "828cc09a-fe2a-4ee1-9a72-a9b480f38b6e", "name": "fa3d92fd-97ad-40ff-9d8f-f84c88373f5c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1813646779377422, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20173832232537287, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fc35cab6-95e9-44c5-b70f-05b92b4d412d", "name": "fc0295ec-7b0d-4e55-bd2d-8d88ed0eabb7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "828cc09a-fe2a-4ee1-9a72-a9b480f38b6e"}}}]}, {"uuid": "f3c39724-bce3-49eb-a332-5055b6ee129b", "name": "load_p1rlv15608_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13d6bce6-9066-43a1-b2b6-00a2a4398958"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fc35cab6-95e9-44c5-b70f-05b92b4d412d"}}}}, {"uuid": "c83a74b2-d475-4147-808e-0dccf1a9a3b4", "name": "3d38d38b-5d2d-4970-b5e3-886dde0671c1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1813646779377422, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20173832232537287, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "002ae075-c151-4cc2-9fb9-85a86472f2f9", "name": "a87fb5a0-40b5-4eee-b194-d1f698ed5f37", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c83a74b2-d475-4147-808e-0dccf1a9a3b4"}}}]}, {"uuid": "9055524e-3ac0-4565-b9cd-93f4591fcec6", "name": "load_p1rlv15608_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13d6bce6-9066-43a1-b2b6-00a2a4398958"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "002ae075-c151-4cc2-9fb9-85a86472f2f9"}}}}, {"uuid": "4212ded5-f581-4764-a59d-65fa5f2a198c", "name": "5d907014-cc5a-402a-8bf4-c18f781cafa2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.046232297850773, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7285366000251032, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "46d7587a-7dad-42d6-b692-57ee52c08570", "name": "443cdf73-68ba-4425-9e0d-2be0e1cf4df1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4212ded5-f581-4764-a59d-65fa5f2a198c"}}}]}, {"uuid": "e5249452-bd5d-4408-aa97-f2be5b14b2f0", "name": "load_p1rlv15616_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43ed408e-35e2-4bca-9060-a0c211aea1e7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "46d7587a-7dad-42d6-b692-57ee52c08570"}}}}, {"uuid": "0384f4b8-3dd0-4a01-b3f9-5c3a03a67deb", "name": "82d07e53-05b9-4605-8c73-35c475f1fa40_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.046232297850773, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7285366000251032, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "acb2dbdb-58a4-4de6-9fc8-e8efcb0a1324", "name": "a2877474-25d5-4c42-a694-63c46491a769", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0384f4b8-3dd0-4a01-b3f9-5c3a03a67deb"}}}]}, {"uuid": "a44343d7-5bcb-4693-96f3-3ad2aa61a044", "name": "load_p1rlv15616_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43ed408e-35e2-4bca-9060-a0c211aea1e7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "acb2dbdb-58a4-4de6-9fc8-e8efcb0a1324"}}}}, {"uuid": "eabfde0e-54b8-44df-bd7e-aea1271f9ace", "name": "0f43caab-2a22-4b0f-8055-033e5a86d4da_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2795803428770153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1698974287191981, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f9eb67dd-74bc-4c46-831e-e02d1fb1d898", "name": "88e50214-eb50-4621-b000-3d73ab001257", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eabfde0e-54b8-44df-bd7e-aea1271f9ace"}}}]}, {"uuid": "dea108c1-e877-4a90-8f38-feaf33fb1e3b", "name": "load_p1rlv15618_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "200aa7d8-0a43-4086-b0e7-f63cae75671d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f9eb67dd-74bc-4c46-831e-e02d1fb1d898"}}}}, {"uuid": "72e1553d-91d7-47c0-a4eb-4e5b1bb3bed1", "name": "80570795-9843-475c-9431-752d767622cc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2795803428770153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1698974287191981, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9519faae-cb8f-4544-8ea7-cb5f9a681c54", "name": "d14c1fab-bf8a-42c8-8b83-33d7dd168bf8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72e1553d-91d7-47c0-a4eb-4e5b1bb3bed1"}}}]}, {"uuid": "9e1f6c2e-94d7-4757-b33b-82228d4eabd2", "name": "load_p1rlv15618_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "200aa7d8-0a43-4086-b0e7-f63cae75671d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9519faae-cb8f-4544-8ea7-cb5f9a681c54"}}}}, {"uuid": "b092f45d-9015-4c29-a4a7-b76faa9b58f0", "name": "9c39cbd7-0fe5-4467-a773-210bfae39bd0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8454259827639654, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5306926284494342, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "065a8765-34d9-4f06-9611-d4f0c1216795", "name": "a23ad787-c2d5-496e-925e-33372bfc20a6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b092f45d-9015-4c29-a4a7-b76faa9b58f0"}}}]}, {"uuid": "f762ccda-562f-486a-9c52-40097d41b4da", "name": "load_p1rlv15619_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905a4857-5d3d-4e51-9ab0-70d634170f92"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "065a8765-34d9-4f06-9611-d4f0c1216795"}}}}, {"uuid": "e4498d19-aa92-4345-a2ac-ff62048aeb4c", "name": "fbbad8a2-7d6a-4e4d-b380-17af10ae674a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8454259827639654, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5306926284494342, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d223123b-5936-4b5f-8033-2e9c6b2c90fb", "name": "3dc826b0-e993-46b2-acdb-f78e8576f816", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e4498d19-aa92-4345-a2ac-ff62048aeb4c"}}}]}, {"uuid": "d30393bc-6418-416e-83ac-29f25e4da89f", "name": "load_p1rlv15619_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905a4857-5d3d-4e51-9ab0-70d634170f92"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d223123b-5936-4b5f-8033-2e9c6b2c90fb"}}}}, {"uuid": "3ea87847-071d-451f-bd19-6d82c1ce111f", "name": "aa9ec67c-7807-4a16-acdf-62bc65f7fa19_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5924067901709626, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.46681640832512994, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "08427ead-ad00-4a10-a10d-e7d4da17a254", "name": "a2e361e0-b106-43a0-906c-35a429e96aea", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3ea87847-071d-451f-bd19-6d82c1ce111f"}}}]}, {"uuid": "1904ede3-a1c8-4565-adc7-d679845b0c95", "name": "load_p1rlv15623_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13f790a1-18c0-498f-8525-fbaf0350947b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "08427ead-ad00-4a10-a10d-e7d4da17a254"}}}}, {"uuid": "4f3fa56d-4b8b-47bc-8a88-d4518112bfbb", "name": "49271121-f195-4dc2-9617-3e41417e9f63_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5924067901709626, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.46681640832512994, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ddfbadbd-d94a-463c-b3fa-a1586a9f8ff3", "name": "e9f05cd5-7af3-4225-81e8-0d9267e8fa64", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4f3fa56d-4b8b-47bc-8a88-d4518112bfbb"}}}]}, {"uuid": "95a7b4d1-8c53-42fd-8fe4-74537a2ee45a", "name": "load_p1rlv15623_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13f790a1-18c0-498f-8525-fbaf0350947b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ddfbadbd-d94a-463c-b3fa-a1586a9f8ff3"}}}}, {"uuid": "1d62a7aa-8b10-44bd-ace9-bf5f8061dd23", "name": "f3ee2678-10a3-407d-a28b-1259924b2b44_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6658189308849048, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3864031015392916, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ee3e309b-bd35-40cd-b2b0-6498a1ff6210", "name": "df422b58-6f34-4522-86e9-cd47c632de13", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1d62a7aa-8b10-44bd-ace9-bf5f8061dd23"}}}]}, {"uuid": "fa99cc7b-2e73-4524-b411-78eacbc75990", "name": "load_p1rlv15625_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb08eda2-b277-4bfd-9ea0-9c36765400bd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ee3e309b-bd35-40cd-b2b0-6498a1ff6210"}}}}, {"uuid": "2a5215a6-8da4-4afa-a0b7-3cef1822b4ef", "name": "8877d052-007c-40eb-a879-4f58aa9e7211_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6658189308849048, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3864031015392916, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b6bfe314-6117-4811-b014-92996f13c84f", "name": "6fa26fb9-a44a-4269-84ab-a6b6259ca31f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2a5215a6-8da4-4afa-a0b7-3cef1822b4ef"}}}]}, {"uuid": "87950dc1-c23f-454f-845e-94f5fbb13603", "name": "load_p1rlv15625_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb08eda2-b277-4bfd-9ea0-9c36765400bd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b6bfe314-6117-4811-b014-92996f13c84f"}}}}, {"uuid": "be3ca802-c7d2-47de-972d-322cd93807e5", "name": "a17e6c75-25ef-446e-861a-3263eef75cc6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3315344999322854, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13574204648198762, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "93b4ac9f-fd66-4459-b9b2-a60a7625fdd6", "name": "1b46f718-4f26-4402-a080-7744de60b05b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "be3ca802-c7d2-47de-972d-322cd93807e5"}}}]}, {"uuid": "ad0a8ed6-24d4-4e8f-ac53-88c9b689021e", "name": "load_p1rlv15632_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ccbef4c-6bf7-4892-a3b9-b51aca495137"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "93b4ac9f-fd66-4459-b9b2-a60a7625fdd6"}}}}, {"uuid": "c810fca3-d772-4a8f-9082-c6e72ac4e6db", "name": "6d0f8720-ca97-4483-85b1-fcfbc3d9a247_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3315344999322854, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13574204648198762, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eb7dc31a-acec-41e8-9d07-1c90bf9490b1", "name": "d7af0015-c346-4b4e-a53e-6fa094559f64", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c810fca3-d772-4a8f-9082-c6e72ac4e6db"}}}]}, {"uuid": "b326beb8-6531-4490-84c5-a9014d18cd2f", "name": "load_p1rlv15632_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ccbef4c-6bf7-4892-a3b9-b51aca495137"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eb7dc31a-acec-41e8-9d07-1c90bf9490b1"}}}}, {"uuid": "9e89186f-82c8-41ae-9f16-c28e00c70659", "name": "d62a87d2-b3fd-4ff1-a057-d63355bf6822_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4063851199490187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16385595528128288, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bbc4101b-7e69-4f71-ae4f-53856d686d1e", "name": "2c8f31ec-0268-4a3f-801f-a40f82c15c62", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9e89186f-82c8-41ae-9f16-c28e00c70659"}}}]}, {"uuid": "375a5e05-3568-4779-b978-37d6522d61fb", "name": "load_p1rlv15633_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce7b60c8-43ee-441d-9f18-5b2722dcc0a7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bbc4101b-7e69-4f71-ae4f-53856d686d1e"}}}}, {"uuid": "9f5b58b3-7848-4775-845e-a70f87019061", "name": "35b90394-c4d5-42e8-b3ed-6a734fc56860_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4063851199490187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16385595528128288, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f85b18e2-a935-4f00-bcc3-eb8850675b5f", "name": "d22eb452-a604-4f20-9803-82933df8d181", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9f5b58b3-7848-4775-845e-a70f87019061"}}}]}, {"uuid": "fd01f3fc-80cc-451d-ba6b-6cdba33c7311", "name": "load_p1rlv15633_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce7b60c8-43ee-441d-9f18-5b2722dcc0a7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f85b18e2-a935-4f00-bcc3-eb8850675b5f"}}}}, {"uuid": "2300e2b1-e466-437d-af39-12dc106ea0f1", "name": "7083a3fa-3140-4ecb-8a87-8c51ca8cac19_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.416529851525178, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1922168413006689, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7b14e0f6-ca0f-4794-8615-bd6fd05cc72d", "name": "ec7fc012-219d-49fd-a2f2-21417ffd3ed0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2300e2b1-e466-437d-af39-12dc106ea0f1"}}}]}, {"uuid": "cc963929-deac-4c2d-93ca-eec6f3895b48", "name": "load_p1rlv15640_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83c2de51-1b04-483c-8ce7-14b9e5e027b9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7b14e0f6-ca0f-4794-8615-bd6fd05cc72d"}}}}, {"uuid": "c18fc0b9-d5ea-4253-b272-6a950aa0a4a2", "name": "20882bd3-8746-4413-a346-e24319680df6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.416529851525178, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1922168413006689, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "73414de7-7f37-44cd-a4ca-74716bb26fa2", "name": "106eb0d3-138e-4640-8725-abd2ec7b195f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c18fc0b9-d5ea-4253-b272-6a950aa0a4a2"}}}]}, {"uuid": "8de61cc1-a633-4ef4-ad8d-12c1c479f199", "name": "load_p1rlv15640_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83c2de51-1b04-483c-8ce7-14b9e5e027b9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "73414de7-7f37-44cd-a4ca-74716bb26fa2"}}}}, {"uuid": "27831177-8035-4f9b-b8ff-9d9ea31439af", "name": "69f11f40-bb60-4012-8526-4aad1d2aa1ab_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7538406343539102, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42176934505781605, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4e2d6287-dbf6-47f8-b6f0-bf31d11f7660", "name": "9556de5c-ea12-4b65-ba76-b3e4676b8b38", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "27831177-8035-4f9b-b8ff-9d9ea31439af"}}}]}, {"uuid": "0b6ca4e4-706a-4f46-abf0-c6bc68a0ddac", "name": "load_p1rlv15641_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4363602a-eb9c-41b8-8130-7bb839f4eb5a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4e2d6287-dbf6-47f8-b6f0-bf31d11f7660"}}}}, {"uuid": "873fe6a2-2e17-4658-b8f6-1a976d9d758f", "name": "8823a533-2fa9-4c9d-b797-0df5529291c2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7538406343539102, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42176934505781605, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "de902fe0-2d32-42b3-a757-0dba337785ad", "name": "89d360e4-e1c1-43c5-bad9-2f3f7ea7c261", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "873fe6a2-2e17-4658-b8f6-1a976d9d758f"}}}]}, {"uuid": "434acaad-5c0d-49d4-a568-2850f9fd6300", "name": "load_p1rlv15641_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4363602a-eb9c-41b8-8130-7bb839f4eb5a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "de902fe0-2d32-42b3-a757-0dba337785ad"}}}}, {"uuid": "b5d548f7-c235-4f56-a5e8-73b437dfec64", "name": "2dcf3af2-8b6d-4f62-ace6-d8e121983252_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.735884899619907, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7862059386133167, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ea218f6e-dfd3-438b-adcf-852aa343204b", "name": "28b3c749-4582-4f26-9e07-d9887cd70465", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5d548f7-c235-4f56-a5e8-73b437dfec64"}}}]}, {"uuid": "31e35185-7faa-4548-a082-94b778d715eb", "name": "load_p1rlv16450_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5f1e7aa-d93a-4164-8bc0-f920259304a8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ea218f6e-dfd3-438b-adcf-852aa343204b"}}}}, {"uuid": "92762c3b-686c-4ce0-9e31-45def15ff6d2", "name": "82753a5d-5757-46fd-b47b-63058b1199e2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.735884899619907, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7862059386133167, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5a3f23f0-a34b-4071-93c5-5d8151415cd1", "name": "8e27ec17-be51-429a-8af7-638943f57ef9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "92762c3b-686c-4ce0-9e31-45def15ff6d2"}}}]}, {"uuid": "6dd3a333-b113-4ad1-9cfc-2ee8193aa02c", "name": "load_p1rlv16450_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5f1e7aa-d93a-4164-8bc0-f920259304a8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5a3f23f0-a34b-4071-93c5-5d8151415cd1"}}}}, {"uuid": "d18f355d-432d-4a81-9f79-60ce72b17264", "name": "cb98fa40-de8c-4a97-bb6c-3b878a09ab9c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5229589832640044, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3359880712066463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7ce996db-a06e-43c8-b644-32f3f75d9413", "name": "8e4e1985-8cc9-45fc-8143-fc433d8de810", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d18f355d-432d-4a81-9f79-60ce72b17264"}}}]}, {"uuid": "9fb0240a-337c-448b-9787-66aea3750bf3", "name": "load_p1rlv16463_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9c505d7-3fb9-4eb5-89c6-c9c8da32fd05"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7ce996db-a06e-43c8-b644-32f3f75d9413"}}}}, {"uuid": "3e585105-6eb1-4266-852c-d96bef3e20ae", "name": "9ac799f5-91b0-4380-a5f3-e07f877df701_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5229589832640044, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3359880712066463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8c691fc0-826c-469b-8458-924b9d4bb2a5", "name": "8bbcadb3-5213-4a50-8ee5-177fdb53534a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3e585105-6eb1-4266-852c-d96bef3e20ae"}}}]}, {"uuid": "22237d0f-60d8-42bf-a53a-99468f18ea7d", "name": "load_p1rlv16463_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9c505d7-3fb9-4eb5-89c6-c9c8da32fd05"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8c691fc0-826c-469b-8458-924b9d4bb2a5"}}}}, {"uuid": "72f9e304-6f77-4048-b244-b47d987386d5", "name": "4354d6de-b840-4a59-921c-48546a5918ba_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.868352089343376, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.8531787232937273, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "93240c18-7579-465b-b310-1d14ad8e8dd2", "name": "1b380adb-20db-4447-a4b5-36eb7224e1cd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72f9e304-6f77-4048-b244-b47d987386d5"}}}]}, {"uuid": "abdb5a0e-b49e-4045-8a50-c71f708e8057", "name": "load_p1rlv16475_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d400b1b2-8404-4b80-b110-6f96e000314f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "93240c18-7579-465b-b310-1d14ad8e8dd2"}}}}, {"uuid": "888d1efa-55da-4fa0-8fdb-34cd43bddd9c", "name": "a7c7a516-35b1-4b3f-879d-b052684964fa_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.868352089343376, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.8531787232937273, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "de871ffd-f009-4ca8-a997-be1e4f88ae66", "name": "28e02cf2-5047-48fa-b542-ae2aa753401c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "888d1efa-55da-4fa0-8fdb-34cd43bddd9c"}}}]}, {"uuid": "7022f268-f6f5-4642-84f1-7377872a39a4", "name": "load_p1rlv16475_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d400b1b2-8404-4b80-b110-6f96e000314f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "de871ffd-f009-4ca8-a997-be1e4f88ae66"}}}}, {"uuid": "e54ec48a-9076-420f-9ddf-0ab004897c81", "name": "ad316ba8-bdcf-4aee-9cab-506969847b73_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8816313976351899, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.38647586315113985, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b570d166-7b24-49d5-88c7-3c2de440b7aa", "name": "46e26fb5-cd03-4009-bee3-b4653939f1ce", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e54ec48a-9076-420f-9ddf-0ab004897c81"}}}]}, {"uuid": "8dc71af4-8b75-4782-aebf-fbdb147c277f", "name": "load_p1rlv16483_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa6db7ee-126d-4aa9-9733-35ff1c1d5992"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b570d166-7b24-49d5-88c7-3c2de440b7aa"}}}}, {"uuid": "7c2bbc90-c373-4787-802b-91686bbd16d5", "name": "090e10fe-03aa-46ba-94f3-4af619297bc0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8816313976351899, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.38647586315113985, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "74fecb5e-7b8c-4aad-8bf6-f551ad043802", "name": "e5f549bd-698c-4aeb-a297-e7da4d5ac566", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7c2bbc90-c373-4787-802b-91686bbd16d5"}}}]}, {"uuid": "4efd8407-afeb-45a9-a658-989c9fd49d4c", "name": "load_p1rlv16483_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa6db7ee-126d-4aa9-9733-35ff1c1d5992"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "74fecb5e-7b8c-4aad-8bf6-f551ad043802"}}}}, {"uuid": "6a389484-bc0c-4d4a-9d31-54a1bac5a030", "name": "517e95b3-d4e7-426f-a862-33d7532e6650_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8285317723273034, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9836303634928509, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50c5124f-e767-48e1-8fa3-c1f23dc1d946", "name": "a0ff77a5-a9f2-47c3-a9f0-0e6549119ed2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6a389484-bc0c-4d4a-9d31-54a1bac5a030"}}}]}, {"uuid": "f0aac045-0e01-4455-a8d7-50f8a24b39c3", "name": "load_p1rlv16507_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27afe70a-9123-4b0c-9f50-b5355aafcf7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50c5124f-e767-48e1-8fa3-c1f23dc1d946"}}}}, {"uuid": "c1f72a93-2c6d-40f0-9e88-066edd0bc299", "name": "2473520e-3c51-4226-8681-2bf2d8f864ed_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8285317723273034, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9836303634928509, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "46e400db-45a5-4016-81f6-e5e8c50fe0cf", "name": "ae99d7bd-fb17-4727-8fa6-b70d61ae23d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c1f72a93-2c6d-40f0-9e88-066edd0bc299"}}}]}, {"uuid": "f9802863-0ac4-4648-9bc4-1868376b0046", "name": "load_p1rlv16507_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27afe70a-9123-4b0c-9f50-b5355aafcf7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "46e400db-45a5-4016-81f6-e5e8c50fe0cf"}}}}, {"uuid": "f3ad0ef9-ac5b-424c-8d55-c35e3ec43d71", "name": "5d16bf4b-825c-48d8-a9f2-9591f938775a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6976007564693765, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0012223642000246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ffe7b4e6-144c-462e-b003-deb4036a99ea", "name": "3d434c4a-07a6-4e66-ac93-41189685d682", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f3ad0ef9-ac5b-424c-8d55-c35e3ec43d71"}}}]}, {"uuid": "fd615f28-bdaf-4b10-9f8b-29ce22898ce0", "name": "load_p1rlv16530_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0333a34b-4027-4d9a-9d4a-f867c8a317bc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ffe7b4e6-144c-462e-b003-deb4036a99ea"}}}}, {"uuid": "00566696-d4c5-4a31-a3ea-5c779c66ed5f", "name": "a348b52e-9808-4ede-8bdb-17768e1e41f4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6976007564693765, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0012223642000246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c715d386-cc2d-42e8-89f5-4da411227d56", "name": "e6ec601a-04c7-431c-883b-c60ba0d73b21", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "00566696-d4c5-4a31-a3ea-5c779c66ed5f"}}}]}, {"uuid": "5b4755a8-7f30-4e67-99cc-615124fa8969", "name": "load_p1rlv16530_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0333a34b-4027-4d9a-9d4a-f867c8a317bc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c715d386-cc2d-42e8-89f5-4da411227d56"}}}}, {"uuid": "7c3feb6e-7699-4b8b-bf81-a1303d4ac613", "name": "b00d351f-caff-4efb-8285-802db0138ef5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4622944887503224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10483650830237357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4aae7ad0-4668-4e2e-b349-05395e064136", "name": "c6792b81-42b7-4e82-b405-1329e781b3c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7c3feb6e-7699-4b8b-bf81-a1303d4ac613"}}}]}, {"uuid": "a6fd724d-b412-4387-baec-28ba0a8ae5c1", "name": "load_p1rlv16541_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f7be042-6681-4694-872d-a1cb701016c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4aae7ad0-4668-4e2e-b349-05395e064136"}}}}, {"uuid": "d789f394-4e99-4645-94a6-dd32d419c082", "name": "b66e098d-d15f-4275-b427-18e96faa709b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4622944887503224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10483650830237357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6377f5e3-4e07-4044-bdd0-6e24cf13cf0b", "name": "1276e012-d2e9-4117-a1a2-3d977832a75a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d789f394-4e99-4645-94a6-dd32d419c082"}}}]}, {"uuid": "87a3f4ec-41e0-4b20-ab89-7fb590e660c7", "name": "load_p1rlv16541_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f7be042-6681-4694-872d-a1cb701016c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6377f5e3-4e07-4044-bdd0-6e24cf13cf0b"}}}}, {"uuid": "6c69e703-71cd-486d-ad05-17837f07fddc", "name": "2ced9ebc-d211-443f-9e72-af7d95d3849a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.962510599658346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.39927803268124257, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3e01c7b8-27b5-4ec3-8f06-3389efbecb65", "name": "9af5c881-7e46-4b5e-a998-959c23794c2e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c69e703-71cd-486d-ad05-17837f07fddc"}}}]}, {"uuid": "94d30e7c-66e1-41e1-9fd0-101444495776", "name": "load_p1rlv16573_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90d9dbe9-f9c9-4a4e-8ada-cb459778687b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3e01c7b8-27b5-4ec3-8f06-3389efbecb65"}}}}, {"uuid": "676745fc-79d7-458c-9e05-6e092caa2b3f", "name": "1a1a8e15-1ec4-4929-97f2-cc5316e1bc83_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.962510599658346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.39927803268124257, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0e2c3022-4cb6-446b-ae2c-3428b4af05af", "name": "336a777f-09ce-4bf3-b11a-3cbe06f7619d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "676745fc-79d7-458c-9e05-6e092caa2b3f"}}}]}, {"uuid": "1b19dde5-8cdf-4897-a926-2c48ebc763a9", "name": "load_p1rlv16573_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90d9dbe9-f9c9-4a4e-8ada-cb459778687b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0e2c3022-4cb6-446b-ae2c-3428b4af05af"}}}}, {"uuid": "17418aba-721c-4315-94ab-f8def94d1c19", "name": "fce4c617-6785-4a22-b6a1-ff8dec801232_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6976007564693765, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0012223642000246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ddd490af-260d-46e4-8ca9-b21cc6bc2d46", "name": "f35dc42e-9781-4443-84df-4a624454cc9f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "17418aba-721c-4315-94ab-f8def94d1c19"}}}]}, {"uuid": "397456e3-3cb5-470b-be37-3e79d3c899ed", "name": "load_p1rlv16584_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "344c6b21-94c9-4912-a19e-69fbae5eed27"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ddd490af-260d-46e4-8ca9-b21cc6bc2d46"}}}}, {"uuid": "f6211fd3-d0ef-414f-8de3-78c78457a87b", "name": "6aa9bc57-2165-459d-b3a6-36c43fcac88b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6976007564693765, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0012223642000246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2a865d4a-7f45-47ee-92b3-1f9e5a08b46e", "name": "81959ead-a5ed-4ab3-b74d-0ab0b5855cbe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f6211fd3-d0ef-414f-8de3-78c78457a87b"}}}]}, {"uuid": "b535f7e2-9aa2-4481-8507-d774c5c8dd99", "name": "load_p1rlv16584_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "344c6b21-94c9-4912-a19e-69fbae5eed27"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2a865d4a-7f45-47ee-92b3-1f9e5a08b46e"}}}}, {"uuid": "7648cf74-49da-4631-b023-8a26cdff5a97", "name": "db32424a-4750-4cf6-8cb1-bca90476f529_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4820522770729507, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1125677048872814, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "80554816-b458-45b0-8147-a0037851a770", "name": "7166e439-29ab-4ca8-97ad-b062ea3cdbf4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7648cf74-49da-4631-b023-8a26cdff5a97"}}}]}, {"uuid": "4e358a7e-2f97-47f3-b250-04a30db6372c", "name": "load_p1rlv16604_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f9ecb3f-8b64-4598-a9d1-d794c6800d33"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "80554816-b458-45b0-8147-a0037851a770"}}}}, {"uuid": "d64daa14-f7d7-453a-b0a2-b461372c8200", "name": "8a74909b-00b5-4d43-a62c-e396702c1c31_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4820522770729507, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1125677048872814, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "888cb114-7f8f-4d27-b18c-9a8bdf45a92e", "name": "2ac3ef4a-cebc-4d3c-a28c-3690ee0ba266", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d64daa14-f7d7-453a-b0a2-b461372c8200"}}}]}, {"uuid": "e0a235d2-9c25-45cd-a2c3-f08de8da1c81", "name": "load_p1rlv16604_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f9ecb3f-8b64-4598-a9d1-d794c6800d33"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "888cb114-7f8f-4d27-b18c-9a8bdf45a92e"}}}}, {"uuid": "6b32ecbb-ef6d-492e-8dcb-52e75307d744", "name": "ad0f3347-eb7f-4599-800f-4b0b8801488a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8791002615066037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24190904367644575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "050f8a43-86e9-440e-9013-a602a5347d35", "name": "a22947a6-bcbc-4935-aba8-86f0843db3d7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6b32ecbb-ef6d-492e-8dcb-52e75307d744"}}}]}, {"uuid": "c35648e4-98a8-4b53-93f4-c9832c9a4772", "name": "load_p1rlv17239_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba567aae-a893-41d3-8fd1-8357d3cab35d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "050f8a43-86e9-440e-9013-a602a5347d35"}}}}, {"uuid": "145622c3-10b0-43f9-b6eb-5fba18da4dc7", "name": "cbe728db-d030-4a08-a9ae-2f266c38827d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8791002615066037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24190904367644575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2d231892-6703-4130-9edf-3084ca95ef2d", "name": "4ea83401-f40a-499f-bbf0-b3f2158897dc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "145622c3-10b0-43f9-b6eb-5fba18da4dc7"}}}]}, {"uuid": "fa50fe3e-5e73-434b-8f50-8a2a6a1d4b63", "name": "load_p1rlv17239_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba567aae-a893-41d3-8fd1-8357d3cab35d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2d231892-6703-4130-9edf-3084ca95ef2d"}}}}, {"uuid": "fcd97511-4190-4064-a54f-9874215e5e8f", "name": "59d5dc07-dbbc-48cc-bfdc-ea9b13fbbd10_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.664483224984605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9538644530515166, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e271eab7-9cd8-42f1-b8c0-0c11acf307d8", "name": "52fd7431-2ac2-402d-ac11-d8f5d4afe61b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fcd97511-4190-4064-a54f-9874215e5e8f"}}}]}, {"uuid": "d2090903-e858-43d0-bed5-eacf872228dd", "name": "load_p1rlv17246_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acfdbe95-2d82-463a-9d1f-6fd2688adf16"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e271eab7-9cd8-42f1-b8c0-0c11acf307d8"}}}}, {"uuid": "1e737e3c-83b0-4326-bf8f-b6acae50638d", "name": "9ee4961e-7303-4ff5-834c-32b092f8dde4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.664483224984605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9538644530515166, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d2309fed-4bd6-4ec1-a07c-9776f9d23797", "name": "d8a40c85-27ed-4609-81cb-53106e525a8b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1e737e3c-83b0-4326-bf8f-b6acae50638d"}}}]}, {"uuid": "6deb03f4-71f9-4740-b29a-428e44a88afa", "name": "load_p1rlv17246_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acfdbe95-2d82-463a-9d1f-6fd2688adf16"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d2309fed-4bd6-4ec1-a07c-9776f9d23797"}}}}, {"uuid": "5b8bf031-4224-4dba-9afb-32fd4c970315", "name": "131b04d8-6670-4981-b729-cd45182c9312_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7073298240395912, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.27247283022117846, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ecdec3fa-0fe5-4adc-94e0-b2686c04e60d", "name": "2f40d2d5-37f0-45ff-bdf2-74489ec2cbf1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b8bf031-4224-4dba-9afb-32fd4c970315"}}}]}, {"uuid": "2a0175b3-9542-4c41-845a-5ef0855a6df3", "name": "load_p1rlv17280_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac80cbea-e10a-491a-ba36-06e9fcf74217"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ecdec3fa-0fe5-4adc-94e0-b2686c04e60d"}}}}, {"uuid": "d9fa4f4e-b7d1-4935-8353-239744c09582", "name": "88ca2756-2a7b-46ec-a7bb-074c65e03a8f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7073298240395912, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.27247283022117846, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9a872ec0-9bac-4b01-9536-7be722032b24", "name": "ad7fd0b0-d4bf-4805-9b76-018d3d997a28", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d9fa4f4e-b7d1-4935-8353-239744c09582"}}}]}, {"uuid": "711295f8-9158-44a8-8b6f-5f1498447996", "name": "load_p1rlv17280_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac80cbea-e10a-491a-ba36-06e9fcf74217"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9a872ec0-9bac-4b01-9536-7be722032b24"}}}}, {"uuid": "67a9a2c0-4038-4037-a2e9-7ff562687f15", "name": "23c1537f-8d8f-42ec-8c6b-6d3010087c0a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7675749799903273, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6204429178040327, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f8fc3ba-b7a7-436a-8419-5672be6c1c6a", "name": "a2d63641-53a1-4222-9271-95b4e71989a1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "67a9a2c0-4038-4037-a2e9-7ff562687f15"}}}]}, {"uuid": "b0ea80f7-43ec-44ce-afb5-79f392497f53", "name": "load_p1rlv17291_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04388b89-16fc-40b3-a060-5bc52032874e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f8fc3ba-b7a7-436a-8419-5672be6c1c6a"}}}}, {"uuid": "6676d674-277d-4c80-8d60-99a5c2e5f3c4", "name": "e6c387a3-ca6b-4306-accd-7e17124f02ae_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7675749799903273, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6204429178040327, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "292dc273-0cd2-4e35-aa1c-0c07bfb32add", "name": "0fd2deb4-9d5f-4a37-8208-13600ea0174d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6676d674-277d-4c80-8d60-99a5c2e5f3c4"}}}]}, {"uuid": "8b720fc4-a00e-41f8-9c68-51dc8f90af7f", "name": "load_p1rlv17291_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04388b89-16fc-40b3-a060-5bc52032874e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "292dc273-0cd2-4e35-aa1c-0c07bfb32add"}}}}, {"uuid": "10e86e9d-ca57-4db7-90d5-16cae37b75ba", "name": "80cbee2f-3ab1-4e74-937c-8f4e543a84e4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8744605841296944, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5892496700768608, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "256c9e8a-d0d8-4d4f-b53b-36e6005cab1b", "name": "30d361c3-0aab-4780-8248-faffdfce3d12", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "10e86e9d-ca57-4db7-90d5-16cae37b75ba"}}}]}, {"uuid": "ddea90dc-2e99-4402-91a1-84c31229f44e", "name": "load_p1rlv17303_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04eb7e32-e372-4cb0-94a7-ee418f400bda"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "256c9e8a-d0d8-4d4f-b53b-36e6005cab1b"}}}}, {"uuid": "2069dad0-4b69-4bcb-8fbf-3000584dfdbc", "name": "252eef92-b83b-4753-a651-aa2df01fb01c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8744605841296944, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5892496700768608, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4205920b-6ffd-4d2e-9965-9c548b00f7ca", "name": "29b34c55-66ec-4ca0-8156-33a3be3c9160", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2069dad0-4b69-4bcb-8fbf-3000584dfdbc"}}}]}, {"uuid": "5a0db9b8-a303-4e8f-8ce6-48034af5b2ce", "name": "load_p1rlv17303_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04eb7e32-e372-4cb0-94a7-ee418f400bda"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4205920b-6ffd-4d2e-9965-9c548b00f7ca"}}}}, {"uuid": "39fd1708-e184-4b5d-9036-627aa4903a72", "name": "f2a8f814-c6b3-47c8-b5d0-91d7bc1c9606_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.446531565278448, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9314679219387375, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2166fe2c-b301-44e5-a91b-374f6818f1b4", "name": "74c3edab-08c0-42f4-9445-44987245fb8f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "39fd1708-e184-4b5d-9036-627aa4903a72"}}}]}, {"uuid": "116e8dc6-181a-4c69-85f1-d6db4517f88d", "name": "load_p1rlv17311_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84ebd9bb-dc50-483d-a3c6-044682d4020c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2166fe2c-b301-44e5-a91b-374f6818f1b4"}}}}, {"uuid": "d45d4101-f6dd-4c03-8d23-4e324061add4", "name": "f28f4b69-0589-4998-834b-45744772adcb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.446531565278448, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9314679219387375, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a4efd325-ab67-4330-8d7d-a62e6aec7d3e", "name": "183af1aa-33b5-47d7-895a-7bab90843791", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d45d4101-f6dd-4c03-8d23-4e324061add4"}}}]}, {"uuid": "b50f50bb-1c6e-428f-87db-f970d8bd0257", "name": "load_p1rlv17311_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84ebd9bb-dc50-483d-a3c6-044682d4020c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a4efd325-ab67-4330-8d7d-a62e6aec7d3e"}}}}, {"uuid": "3b56692e-8300-4a54-b121-6b2f3e460062", "name": "6110bf2f-bfca-4a3b-9a92-e766fd8b17b9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.1528026683641635, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1483162213006746, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "025f9caf-f565-4cfd-afee-aee4bbdd1814", "name": "ed801105-f860-41fb-b2cb-97abb0aba42d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3b56692e-8300-4a54-b121-6b2f3e460062"}}}]}, {"uuid": "dc660c7e-6795-4d0c-b2d2-a293b5ad6c20", "name": "load_p1rlv17345_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ead5953-70f2-4db2-ba4d-d203c91d85c1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "025f9caf-f565-4cfd-afee-aee4bbdd1814"}}}}, {"uuid": "e3547a41-5cc3-4d5a-b8c1-443e4d8458eb", "name": "2c56459d-f1c9-4ea4-a11a-6145c16e5d9c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.1528026683641635, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1483162213006746, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "66a2f399-d485-4762-85b5-8a8609023535", "name": "396cda2b-d69c-48ed-a339-5569d54a14c4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e3547a41-5cc3-4d5a-b8c1-443e4d8458eb"}}}]}, {"uuid": "c7c05374-7e21-4d77-91d3-ef29d9ff446d", "name": "load_p1rlv17345_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ead5953-70f2-4db2-ba4d-d203c91d85c1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "66a2f399-d485-4762-85b5-8a8609023535"}}}}, {"uuid": "54c6339c-d9dd-4aee-9394-c9e0b47a0ad4", "name": "2142fbb6-48f3-4fa5-96e6-6078c0281251_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5261964028176471, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5335215898246958, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "38a6dfe5-5a67-41af-8cdb-f85c2ed8074f", "name": "3abae5ba-902f-489b-ac67-d322cfc39009", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "54c6339c-d9dd-4aee-9394-c9e0b47a0ad4"}}}]}, {"uuid": "ef1c7d14-31c7-428c-9e7f-77573cc919e4", "name": "load_p1rlv17347_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d98640c6-d8aa-44e4-9ecf-5998152d3f7d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "38a6dfe5-5a67-41af-8cdb-f85c2ed8074f"}}}}, {"uuid": "d8bdd3b2-05e8-4baa-989c-71c97851d72a", "name": "478c6353-119e-4c78-99f0-8843ffd338db_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5261964028176471, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5335215898246958, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "383e8d73-e53c-4d55-8738-c313c36771e2", "name": "17dae6e6-7c19-4bae-b2cf-b0cc703ca8d4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d8bdd3b2-05e8-4baa-989c-71c97851d72a"}}}]}, {"uuid": "e63b5a6b-93d0-430a-8209-4d24137aebea", "name": "load_p1rlv17347_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d98640c6-d8aa-44e4-9ecf-5998152d3f7d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "383e8d73-e53c-4d55-8738-c313c36771e2"}}}}, {"uuid": "ae5cf2b9-af7a-496d-94ee-9bf57047dee6", "name": "e5e8940f-84fa-4ec3-8975-714342c23e01_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1461342593009323, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5165512162199262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6fab1a1c-4a75-4dd4-930a-b92164297677", "name": "a37d4c59-cf96-4e28-b72c-4b0f54142d95", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ae5cf2b9-af7a-496d-94ee-9bf57047dee6"}}}]}, {"uuid": "0db124db-f2cf-452e-af15-005da2d72994", "name": "load_p1rlv17351_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2695decb-d268-46b2-8604-9c33dc90518b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6fab1a1c-4a75-4dd4-930a-b92164297677"}}}}, {"uuid": "72d51562-9cfa-4874-ab5b-1a14664df786", "name": "4c5373c5-b67d-4963-ad2a-c14c49a86058_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1461342593009323, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5165512162199262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "864ed71a-eb04-45e5-b8fa-07574a13b6e3", "name": "73a98dfa-1d29-4054-a6e4-d627fa9e4407", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72d51562-9cfa-4874-ab5b-1a14664df786"}}}]}, {"uuid": "2cb117f5-e198-4644-b51e-fea0f165b412", "name": "load_p1rlv17351_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2695decb-d268-46b2-8604-9c33dc90518b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "864ed71a-eb04-45e5-b8fa-07574a13b6e3"}}}}, {"uuid": "a1508534-c554-4a7d-ac1d-5ad0675b7b51", "name": "3ca2e239-a8d3-48d2-8295-0bd4717ea50c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3232710990419903, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5137832846214487, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f36cea0-29e7-467b-8526-a245406e1116", "name": "7874fd6c-3bb4-4bc4-ba13-b84a17dc0816", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a1508534-c554-4a7d-ac1d-5ad0675b7b51"}}}]}, {"uuid": "8295aded-e172-4d6b-a633-3b9c8e2455d9", "name": "load_p1rlv17353_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f34e3e4e-bebd-4148-bcc7-cbfbecd73a2f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f36cea0-29e7-467b-8526-a245406e1116"}}}}, {"uuid": "c9828856-d2c7-48b9-8226-5488cececd61", "name": "24908e2e-d087-4018-b785-36f46ac813b3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3232710990419903, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5137832846214487, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0add286a-19e4-4b8d-9bda-00b9c2e5fcfa", "name": "a7a56e81-5fdc-4f18-baf3-05794ccd7f2e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9828856-d2c7-48b9-8226-5488cececd61"}}}]}, {"uuid": "2767aad3-6719-4959-afa3-9482f210f809", "name": "load_p1rlv17353_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f34e3e4e-bebd-4148-bcc7-cbfbecd73a2f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0add286a-19e4-4b8d-9bda-00b9c2e5fcfa"}}}}, {"uuid": "9bc673b5-7b9b-4aa3-ad4e-22d7ec4068b9", "name": "0f4380b6-64d1-427f-8eb3-dd485b015c70_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5604078463831266, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5882122505209306, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "56dc1c65-0c11-445a-a030-11c2775fcfe1", "name": "f4992301-55dc-469d-bbd6-a908b8faa4c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9bc673b5-7b9b-4aa3-ad4e-22d7ec4068b9"}}}]}, {"uuid": "9fe63a69-17bf-46d7-8bc0-704c3f433fae", "name": "load_p1rlv17357_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf6f74e5-7aa3-4333-bd37-3ce486d54a01"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "56dc1c65-0c11-445a-a030-11c2775fcfe1"}}}}, {"uuid": "8d77143d-1380-4250-a50a-e2244879c93d", "name": "c833d713-1517-4209-bc87-50c6feb870d5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5604078463831266, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5882122505209306, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "60323c30-163d-4b00-8887-89f05a5c7679", "name": "ad5709c4-84f7-4133-b49e-13f5194ccf6e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8d77143d-1380-4250-a50a-e2244879c93d"}}}]}, {"uuid": "fa9b2054-5253-4415-8889-259ad0b84cb5", "name": "load_p1rlv17357_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf6f74e5-7aa3-4333-bd37-3ce486d54a01"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "60323c30-163d-4b00-8887-89f05a5c7679"}}}}, {"uuid": "0004e21c-fcf1-4336-8757-a830465658bd", "name": "7252e071-aae1-44aa-a36f-3458e438804d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.567401274738218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6497123013243786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b2137268-c524-4b5f-a351-ffca79fa6184", "name": "c96b7d7f-9fbb-4a4e-ac22-6c17f2a937e0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0004e21c-fcf1-4336-8757-a830465658bd"}}}]}, {"uuid": "5866fcc4-8763-4e06-8c22-e45bba83eeda", "name": "load_p1rlv17361_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c705333f-6f1a-4a76-a02e-eaa859e99b70"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b2137268-c524-4b5f-a351-ffca79fa6184"}}}}, {"uuid": "aa0b02dc-dd07-40da-953a-4563476e6b85", "name": "583fa5ad-46f4-4b34-a1fd-8b637038e0b6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.567401274738218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6497123013243786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3c48eb75-79db-455e-acea-d04d9228136e", "name": "40a2a226-9af9-465a-98a1-30ac408dc218", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aa0b02dc-dd07-40da-953a-4563476e6b85"}}}]}, {"uuid": "df57747a-1083-4403-b872-5fa1c16e3951", "name": "load_p1rlv17361_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c705333f-6f1a-4a76-a02e-eaa859e99b70"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3c48eb75-79db-455e-acea-d04d9228136e"}}}}, {"uuid": "21bb361e-140f-456c-867f-44050003f17a", "name": "a83313d8-cf7c-4295-8b8f-b5ccfde74f81_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.582045467287543, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.1165769169460202, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0344d223-50ec-43ff-9c12-5c3fae83d370", "name": "652b3ce1-f545-4216-a860-97b04ba23934", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "21bb361e-140f-456c-867f-44050003f17a"}}}]}, {"uuid": "9406461e-6e4c-4502-a0a6-9614beb56faf", "name": "load_p1rlv17378_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08709e25-b030-4801-ae00-c4879556d8b1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0344d223-50ec-43ff-9c12-5c3fae83d370"}}}}, {"uuid": "713e7ec4-ff6e-4d92-b490-46362a155cb1", "name": "1ac7f2e1-6b1d-4883-afdd-319145a5ce64_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.582045467287543, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.1165769169460202, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d0345c42-36a9-4e16-95a9-4918e096f297", "name": "37bd6084-79d6-414b-a304-86a2d943c6a4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "713e7ec4-ff6e-4d92-b490-46362a155cb1"}}}]}, {"uuid": "9e157d0c-0565-4de8-92f7-1bc70e4014bb", "name": "load_p1rlv17378_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08709e25-b030-4801-ae00-c4879556d8b1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d0345c42-36a9-4e16-95a9-4918e096f297"}}}}, {"uuid": "43bb55d1-718c-46de-8ca2-64642aa77b21", "name": "cb9facd3-eec8-422b-8dc2-06031991e10e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.833192950896713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0261472784856227, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e11461e0-e866-4176-85d0-d4ba5f5eaaf2", "name": "f44f14d3-16b1-42c3-9d87-a8f0f6e278f6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "43bb55d1-718c-46de-8ca2-64642aa77b21"}}}]}, {"uuid": "3c4a47db-8ffa-4ba2-852d-3df52e0e6aa6", "name": "load_p1rlv17383_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e1ad135-904d-47ed-ae74-32b38e1c2f88"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e11461e0-e866-4176-85d0-d4ba5f5eaaf2"}}}}, {"uuid": "6fe8413f-9acd-4df9-804d-3d71bd46fca3", "name": "b1eaef3e-9804-4d8a-a91a-acc53f697d5a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.833192950896713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0261472784856227, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6770a518-c900-41f2-a123-1488f7553cb8", "name": "259d81e9-8e67-4f7f-b719-ca0ba0de5c84", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6fe8413f-9acd-4df9-804d-3d71bd46fca3"}}}]}, {"uuid": "5212b428-d8b3-4f9a-a450-7f11c353f06e", "name": "load_p1rlv17383_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e1ad135-904d-47ed-ae74-32b38e1c2f88"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6770a518-c900-41f2-a123-1488f7553cb8"}}}}, {"uuid": "4ab1034a-22fe-4aaf-bf2b-3173f0915153", "name": "1e4d1724-790f-4aa3-a8d2-7ddcac6701a7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4147996191793286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7367936950300052, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "806d8710-c2d5-4753-b051-9ab47963f96f", "name": "7d275180-3049-4299-b88f-ef15fa8c8e3b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4ab1034a-22fe-4aaf-bf2b-3173f0915153"}}}]}, {"uuid": "356607c3-77d9-4189-9190-1ddafe1a961f", "name": "load_p1rlv17385_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e835b413-3307-49ef-ad69-cf18a5ae7cfb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "806d8710-c2d5-4753-b051-9ab47963f96f"}}}}, {"uuid": "838a242a-9611-443f-8c74-a88ff07a6caf", "name": "b2524670-8066-4464-960c-cb129261ded3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4147996191793286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7367936950300052, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4b5a2eae-e238-40d8-8baf-092e6388f195", "name": "dc596592-87c6-4f2e-aa82-a131c6439d44", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "838a242a-9611-443f-8c74-a88ff07a6caf"}}}]}, {"uuid": "4cc6a621-48bf-468c-8e56-766fac8208f2", "name": "load_p1rlv17385_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e835b413-3307-49ef-ad69-cf18a5ae7cfb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4b5a2eae-e238-40d8-8baf-092e6388f195"}}}}, {"uuid": "88b390e3-39d8-45bf-ae83-4d940000f48d", "name": "44b92c1f-cb76-49b0-900f-2ce73682d7aa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4341422169696036, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7357531788704136, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2965e5ae-a370-491d-bdb3-cc58fce2fb1b", "name": "c6281ae0-d87a-4b54-8fd1-9841a114e928", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "88b390e3-39d8-45bf-ae83-4d940000f48d"}}}]}, {"uuid": "697b77fe-e657-4fd7-b89b-d800d852f3a8", "name": "load_p1rlv17387_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "55382019-a1a5-40fd-b90a-072af40c2258"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2965e5ae-a370-491d-bdb3-cc58fce2fb1b"}}}}, {"uuid": "52de8749-2ec3-468f-a447-0c09d80b121f", "name": "b3e054d4-a5c9-4c00-bfb1-417a6151ff6c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4341422169696036, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7357531788704136, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "62c675f5-9c89-4388-b098-c8b697565974", "name": "ac2db679-d9a8-4f39-9764-967a6122356c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "52de8749-2ec3-468f-a447-0c09d80b121f"}}}]}, {"uuid": "4fa2fec5-5280-47dd-ace4-31d79610be5d", "name": "load_p1rlv17387_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "55382019-a1a5-40fd-b90a-072af40c2258"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "62c675f5-9c89-4388-b098-c8b697565974"}}}}, {"uuid": "0ca0f37c-a67b-40c0-945f-75485e693773", "name": "d89e5876-38f6-491b-ac24-1332746712e1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3557486353305213, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.524803205527562, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "229a6a7d-4723-41f9-b305-086b43fbf58e", "name": "b786ccbb-08f3-45f5-8f8d-e4fcf7fbd606", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0ca0f37c-a67b-40c0-945f-75485e693773"}}}]}, {"uuid": "f1f220d6-2c2d-4e91-bba9-6db42c260a03", "name": "load_p1rlv17391_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "169a22de-bb0a-4056-8910-151125c4ff9e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "229a6a7d-4723-41f9-b305-086b43fbf58e"}}}}, {"uuid": "3dbbb271-6748-435a-ac2a-880d5a37dc41", "name": "92c492ce-5b88-465c-8762-6a7de937bdd0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3557486353305213, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.524803205527562, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "187b5a26-62fe-4ec7-8514-c24ec27c8921", "name": "08f3dbc1-7f29-4b75-93f8-50b00087a8c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3dbbb271-6748-435a-ac2a-880d5a37dc41"}}}]}, {"uuid": "1002dba4-77bd-4cc9-b627-2a849d502d9b", "name": "load_p1rlv17391_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "169a22de-bb0a-4056-8910-151125c4ff9e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "187b5a26-62fe-4ec7-8514-c24ec27c8921"}}}}, {"uuid": "7b009349-73d7-4acb-9521-a26b06608d33", "name": "c837bdf3-fdf5-44f6-a1a8-7ee9ec55368f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.0707881481560175, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.1283140369898392, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "579385c8-f0f6-4477-b08a-a8ab9272c314", "name": "b6b4f40e-9c6f-4edf-a93e-c3923f293c9d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b009349-73d7-4acb-9521-a26b06608d33"}}}]}, {"uuid": "bb753700-3f23-44b4-b12e-611167da5587", "name": "load_p1rlv17394_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea560bcb-f930-4f42-ae45-3a60f36fdbb7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "579385c8-f0f6-4477-b08a-a8ab9272c314"}}}}, {"uuid": "3019877e-d0cb-43f8-8ab8-7519b5ad0168", "name": "82621ccf-7bba-48da-acb6-e4a98de4bbbf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.0707881481560175, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.1283140369898392, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ed8335fc-7c31-4da7-94a9-4666fecbf066", "name": "435980bf-ebd6-4c7b-9691-da263768536d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3019877e-d0cb-43f8-8ab8-7519b5ad0168"}}}]}, {"uuid": "ac8d96c4-d602-4fd1-9be2-5b10ed7c810c", "name": "load_p1rlv17394_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea560bcb-f930-4f42-ae45-3a60f36fdbb7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ed8335fc-7c31-4da7-94a9-4666fecbf066"}}}}, {"uuid": "5a5e5d7a-03e7-4a56-843e-84c1f6073e79", "name": "e496bdb3-1418-4e6b-a79b-952a4ec8d05a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.772705532239135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.33568286747913667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "70f7dfe6-a16a-426e-9286-34c5a396ced9", "name": "2979b272-bbde-4390-9125-d87da755935e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5a5e5d7a-03e7-4a56-843e-84c1f6073e79"}}}]}, {"uuid": "a69d0934-805d-44c8-8035-3bb4e1ad5e76", "name": "load_p1rlv17397_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d38cdffb-41be-48aa-8a03-c6525dd01037"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "70f7dfe6-a16a-426e-9286-34c5a396ced9"}}}}, {"uuid": "f35f7daf-422b-4ca4-af37-55eb6cef9b4c", "name": "8a1965b2-8b0c-4bc1-bc76-807ba9d11f4d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.772705532239135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.33568286747913667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dd91b777-3ae2-4333-923c-44c405bace58", "name": "0f76aa58-5610-4d56-bd20-56a677fd9318", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f35f7daf-422b-4ca4-af37-55eb6cef9b4c"}}}]}, {"uuid": "144ad946-e543-4e87-8c77-837a8d8da3b0", "name": "load_p1rlv17397_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d38cdffb-41be-48aa-8a03-c6525dd01037"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dd91b777-3ae2-4333-923c-44c405bace58"}}}}, {"uuid": "2407d8a8-67ea-4de5-9750-c11eb0683256", "name": "1db87372-bb6e-458b-a85f-4b38c1970474_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.072452566650022, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.19566580727582514, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e7c63da0-a165-46bd-aaf3-9d0575264d2f", "name": "0e15e527-5779-4f67-b1fe-61159d545837", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2407d8a8-67ea-4de5-9750-c11eb0683256"}}}]}, {"uuid": "3c899519-7224-4885-9d02-ee292723af0b", "name": "load_p1rlv17400_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63177299-2842-4e0d-bf17-7bd2b0afe9a2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e7c63da0-a165-46bd-aaf3-9d0575264d2f"}}}}, {"uuid": "3a3f2217-6cfb-4fad-89ac-4d06b8bc5bac", "name": "31309af2-1f78-4d21-9067-f5f127248951_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.072452566650022, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.19566580727582514, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d2669ad4-1f07-4b52-890e-83578641b89f", "name": "fb7a1148-b012-479a-adc2-a72ddc85c28e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3a3f2217-6cfb-4fad-89ac-4d06b8bc5bac"}}}]}, {"uuid": "7ef8ddb5-6d01-40c3-a749-97ba63adcdc0", "name": "load_p1rlv17400_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63177299-2842-4e0d-bf17-7bd2b0afe9a2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d2669ad4-1f07-4b52-890e-83578641b89f"}}}}, {"uuid": "5b874b04-da0b-4a51-bc6f-b387b1b951bd", "name": "59b22aa8-fbba-47e3-ab06-2534e76dd4d8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.799969889792979, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7055837837850989, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "24009d36-0cfe-4c27-8da0-4724252c4a08", "name": "f6c70340-8718-4978-baad-62577cbddc6d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b874b04-da0b-4a51-bc6f-b387b1b951bd"}}}]}, {"uuid": "d447dc1f-1c26-48c1-a2e3-570c6805d19c", "name": "load_p1rlv17403_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d61897a-cdac-4b4a-8812-8a8692a3d958"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "24009d36-0cfe-4c27-8da0-4724252c4a08"}}}}, {"uuid": "c1bd056d-22a3-4b0d-b9b6-30dab96ccba7", "name": "f5c00162-a7ca-4860-8b51-9d1298ee15be_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.799969889792979, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7055837837850989, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "af5e10e5-e0dc-4186-8e57-3edc6f6e524c", "name": "1efdaafa-c6c4-417f-8ea5-c2cf301c0219", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c1bd056d-22a3-4b0d-b9b6-30dab96ccba7"}}}]}, {"uuid": "764b567c-a4e5-4d1f-a784-9dda29a803e5", "name": "load_p1rlv17403_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d61897a-cdac-4b4a-8812-8a8692a3d958"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "af5e10e5-e0dc-4186-8e57-3edc6f6e524c"}}}}, {"uuid": "5c7e67f9-eb74-4072-bd15-aaf6c3dfadf1", "name": "982ef7b8-e286-439a-ae6c-c7188ec2f61a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2075389461119934, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3167249782629938, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7842d907-a8f8-4936-b8eb-c87fb3c1212a", "name": "37fe09d7-e1c6-460c-82f8-2ecbf0af9189", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5c7e67f9-eb74-4072-bd15-aaf6c3dfadf1"}}}]}, {"uuid": "e5ee68a5-e0bc-4a07-9fde-5f3a7730db64", "name": "load_p1rlv17405_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b50de14e-9a09-4f61-8998-0979f33b0d0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7842d907-a8f8-4936-b8eb-c87fb3c1212a"}}}}, {"uuid": "01b8414f-5666-464c-8250-fe528292c693", "name": "06d7800b-e9df-45f5-8302-dd539204b00e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2075389461119934, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3167249782629938, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b91c17c7-c950-4a98-bfcc-ac5bb84edf1e", "name": "c1b90e55-7f45-45e5-8a76-35326021fb6b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "01b8414f-5666-464c-8250-fe528292c693"}}}]}, {"uuid": "8a18a6a3-16ec-4cb1-a1b9-d836e6e65e29", "name": "load_p1rlv17405_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b50de14e-9a09-4f61-8998-0979f33b0d0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b91c17c7-c950-4a98-bfcc-ac5bb84edf1e"}}}}, {"uuid": "f588d3ad-fa76-478d-a91d-7bfce980b80b", "name": "3aaf73cf-4754-4d6a-a3af-42a02d25ccfd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2162240825393356, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.47013804182089236, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0be405d0-1eca-469c-80fc-ae833e8edba7", "name": "1c3b8c48-1d81-408e-94d1-45c355e21042", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f588d3ad-fa76-478d-a91d-7bfce980b80b"}}}]}, {"uuid": "a79e9642-e380-4811-94a3-a8e3ef214797", "name": "load_p1rlv17407_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65de341c-589f-4bf9-a708-26fcc94a6c0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0be405d0-1eca-469c-80fc-ae833e8edba7"}}}}, {"uuid": "39f99665-53c4-4897-8ee8-39b15c3c2d3d", "name": "90a1466b-6d62-48c2-820f-ff45af8d6778_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2162240825393356, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.47013804182089236, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ce0e992d-7170-43f0-b60a-0bc2db1ddd4f", "name": "5a438f1e-3ff8-47f7-a75c-272825c559c7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "39f99665-53c4-4897-8ee8-39b15c3c2d3d"}}}]}, {"uuid": "43efa592-e32e-40e2-bdd9-1b958d3c908d", "name": "load_p1rlv17407_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65de341c-589f-4bf9-a708-26fcc94a6c0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ce0e992d-7170-43f0-b60a-0bc2db1ddd4f"}}}}, {"uuid": "9de5024a-5503-4cee-bd35-09ef1bf4e580", "name": "7a92c937-bcf1-473f-aa95-62ac42cde235_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2816928104449037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4107329194522798, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "347d276f-d16b-46bf-99e7-1c5edbff94ab", "name": "aab4f704-c723-4488-9b50-f2debc755a5e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9de5024a-5503-4cee-bd35-09ef1bf4e580"}}}]}, {"uuid": "8350ccd7-b3f4-40f6-85b2-ccce48b7a5cd", "name": "load_p1rlv17415_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86b2527b-73c3-41c4-8ac2-7cb0e8bc2a7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "347d276f-d16b-46bf-99e7-1c5edbff94ab"}}}}, {"uuid": "b65a617e-98cd-4679-b909-11df11aba0ff", "name": "ce339973-1e65-4efc-8f33-b9f2860fe8bb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2816928104449037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4107329194522798, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "77228ec7-1d24-4bdb-933c-2eef13a771d5", "name": "37f2666b-debc-48db-b76c-446fbf120c0e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b65a617e-98cd-4679-b909-11df11aba0ff"}}}]}, {"uuid": "bd730a82-6946-45dd-849e-314b29a96e03", "name": "load_p1rlv17415_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86b2527b-73c3-41c4-8ac2-7cb0e8bc2a7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "77228ec7-1d24-4bdb-933c-2eef13a771d5"}}}}, {"uuid": "be257be2-6154-459a-9727-7434eab3ae9b", "name": "71b95e00-0e54-42ef-9fbb-ba7688857464_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.524011463187128, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7498872254128004, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d2e3f0b4-e35d-47aa-aa3c-057777b11819", "name": "16446f09-2dc2-43b1-abdd-bc9b03e70549", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "be257be2-6154-459a-9727-7434eab3ae9b"}}}]}, {"uuid": "aab56419-c994-43b3-acb6-4dc12758f78e", "name": "load_p1rlv17416_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64a56527-23a9-4229-aa25-f6a45f2187f4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d2e3f0b4-e35d-47aa-aa3c-057777b11819"}}}}, {"uuid": "9c6ca403-fd85-4b35-8892-013f17f967c1", "name": "dbeb95f5-8f49-47f6-9494-bd80cecb550e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.524011463187128, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7498872254128004, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fc931318-a8a4-493d-8371-27e3480f96e4", "name": "fea0aa3d-333a-4590-beec-7efce1279967", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9c6ca403-fd85-4b35-8892-013f17f967c1"}}}]}, {"uuid": "9361bc29-535d-4b5e-ab5c-b66b504f9f0c", "name": "load_p1rlv17416_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64a56527-23a9-4229-aa25-f6a45f2187f4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fc931318-a8a4-493d-8371-27e3480f96e4"}}}}, {"uuid": "9476faa4-9250-476c-8b03-68ef2566c80d", "name": "ee8ddc70-1c84-4dee-851c-1e58d1c6a2b7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.887268818021247, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.0124643291307467, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5031ad5c-b431-4be9-8d68-e0332e5699bb", "name": "52519b40-3f15-4cd1-b12a-27b5543ef4b5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9476faa4-9250-476c-8b03-68ef2566c80d"}}}]}, {"uuid": "c3fa75f3-7af0-4bd3-89e9-711d7614221f", "name": "load_p1rlv17417_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67003f0f-6690-469e-82c0-63949ee5241e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5031ad5c-b431-4be9-8d68-e0332e5699bb"}}}}, {"uuid": "1d75b5b1-a939-4899-9865-3e31ae1af64f", "name": "b9cbac1c-1576-4db1-a031-24fb551f1495_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.887268818021247, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.0124643291307467, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "85a852a4-0bd8-49ab-96ff-d748358a5287", "name": "b9af2d56-3844-4983-92db-339d49d0ef67", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1d75b5b1-a939-4899-9865-3e31ae1af64f"}}}]}, {"uuid": "14c2f474-05ed-47f4-a37f-e4c8361d4cb2", "name": "load_p1rlv17417_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67003f0f-6690-469e-82c0-63949ee5241e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "85a852a4-0bd8-49ab-96ff-d748358a5287"}}}}, {"uuid": "8cbbd0b1-9a4e-45dc-a1c9-b42a1661df65", "name": "3b3605a5-1da1-44ca-8aa7-b65e0fe15dd0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1219512592986662, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8685822493081499, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c8ae20d1-5b04-4bcc-a716-a7b254a720b4", "name": "7c39d8b1-a023-4667-9efd-77168170d85a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8cbbd0b1-9a4e-45dc-a1c9-b42a1661df65"}}}]}, {"uuid": "73aba28a-da22-4d76-8ef8-a166f2a20c31", "name": "load_p1rlv19574_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf457d88-958c-446a-9584-73be8c609bbe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c8ae20d1-5b04-4bcc-a716-a7b254a720b4"}}}}, {"uuid": "491cda37-a219-453c-bd7a-f818d86d7c69", "name": "d5bedc31-12ea-41fa-8b0e-3b77d6a70181_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1219512592986662, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8685822493081499, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "88ee732c-b169-4bbe-8ff7-5080f5252a9e", "name": "b827c4c3-d0e7-4405-a386-12643b337264", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "491cda37-a219-453c-bd7a-f818d86d7c69"}}}]}, {"uuid": "ebd41626-5df8-4131-9e56-6557ffebf1f1", "name": "load_p1rlv19574_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf457d88-958c-446a-9584-73be8c609bbe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "88ee732c-b169-4bbe-8ff7-5080f5252a9e"}}}}, {"uuid": "01b83cc5-088b-4535-b8c6-2f6d119cdc29", "name": "e9084385-43f4-4dcc-a766-b59a6f16cf00_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.817160338362793, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.8654854383625104, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2e5ea7d6-5d3e-4ab2-a2a8-f4b47aceb960", "name": "434ed16a-7e6f-4fc1-9fab-5afd87d35143", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "01b83cc5-088b-4535-b8c6-2f6d119cdc29"}}}]}, {"uuid": "ff4b85f9-f026-4da1-bb90-b0daebe67df4", "name": "load_p1rlv19608_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f917b142-d59f-4a51-8c3b-913feb53411d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2e5ea7d6-5d3e-4ab2-a2a8-f4b47aceb960"}}}}, {"uuid": "fc108728-c806-46c7-9d22-68ded33066cc", "name": "c02ebb55-f9f3-468b-9fc6-b92bc289e1f3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.817160338362793, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.8654854383625104, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "31ed6c2a-ae9e-4a5e-aa55-bef73c08d0d7", "name": "c516f3fc-4e7c-484f-9646-592d6aba09da", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fc108728-c806-46c7-9d22-68ded33066cc"}}}]}, {"uuid": "cd9175ba-3277-41e9-9fe7-929229dfdf54", "name": "load_p1rlv19608_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f917b142-d59f-4a51-8c3b-913feb53411d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "31ed6c2a-ae9e-4a5e-aa55-bef73c08d0d7"}}}}, {"uuid": "861b9adc-05fe-4dee-ae1f-f543c31f61eb", "name": "48772389-aa31-4394-b8e2-a2d7dccbce94_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.931347600748843, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.97768534997531, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cf3c100b-93d4-4c17-8d10-cdb0d190a302", "name": "e2672745-f7ac-400b-b48c-7b1c6bc1726e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "861b9adc-05fe-4dee-ae1f-f543c31f61eb"}}}]}, {"uuid": "3eead1e5-07f0-4ee7-84c6-07dcd4f130b0", "name": "load_p1rlv19610_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "813f887e-6807-4ffc-90bf-bd30cde9a9df"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cf3c100b-93d4-4c17-8d10-cdb0d190a302"}}}}, {"uuid": "01550101-b582-41aa-ae25-30f44134001d", "name": "28fec7d8-95f1-4a68-b4d3-a15cbfab2792_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.931347600748843, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.97768534997531, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3e1afdcd-ce9c-4989-8c68-15db2c7114bf", "name": "8255ef47-9ab6-4f7d-b7e6-8ef9d13464aa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "01550101-b582-41aa-ae25-30f44134001d"}}}]}, {"uuid": "c27da2d6-a9d3-47c2-9056-b49f5f2fff1f", "name": "load_p1rlv19610_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "813f887e-6807-4ffc-90bf-bd30cde9a9df"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3e1afdcd-ce9c-4989-8c68-15db2c7114bf"}}}}, {"uuid": "5985b63c-147a-4326-bafe-41ba848dea30", "name": "8638f04b-97f9-478b-8801-4cc733147fde_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5877230897388055, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4388767979233367, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "795a41ee-4f11-4851-bb52-ec20deb75787", "name": "52439e00-1f5a-4a03-badb-53c010a26c68", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5985b63c-147a-4326-bafe-41ba848dea30"}}}]}, {"uuid": "1296b321-b4be-4bed-8bf8-b44a0438459a", "name": "load_p1rlv19616_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be1b9922-2426-4726-9e5a-bcd33f444b57"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "795a41ee-4f11-4851-bb52-ec20deb75787"}}}}, {"uuid": "2d397e2e-5344-4333-820f-7894baf42aef", "name": "79d92001-bc92-4823-9e1c-851734be8689_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5877230897388055, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4388767979233367, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c32a656-137e-4d99-97c7-0e842dae33e9", "name": "80876c3d-d8c5-47d7-ae76-e3a9ab056fa7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2d397e2e-5344-4333-820f-7894baf42aef"}}}]}, {"uuid": "2a53dcc4-8c69-4632-b1af-ef95e2bbb525", "name": "load_p1rlv19616_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be1b9922-2426-4726-9e5a-bcd33f444b57"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c32a656-137e-4d99-97c7-0e842dae33e9"}}}}, {"uuid": "3ffd9aeb-ffaf-4c77-988f-21934028f3fb", "name": "a70da804-57f4-494b-905e-f44e64ad7b5f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.925260736902077, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.726135012516628, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "00c79078-4ffb-4f0f-855a-ca8dc265cd1e", "name": "272f4a4f-b213-4932-b85f-8e9af0e5892c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3ffd9aeb-ffaf-4c77-988f-21934028f3fb"}}}]}, {"uuid": "c74b9f6c-f9ba-4508-a774-4728d5a2ee91", "name": "load_p1rlv19640_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e90f763-682e-4771-976c-9cd736b72133"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "00c79078-4ffb-4f0f-855a-ca8dc265cd1e"}}}}, {"uuid": "c23552af-3ba4-41b2-b568-a394025c6c76", "name": "62b10e40-2852-42e5-9e8e-a772162d2bc9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.925260736902077, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.726135012516628, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6bed2d9c-e8f4-4ae5-a8c9-40896dc8e08e", "name": "3f9169a6-f8b4-41a8-b7de-17d6058ae1ac", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c23552af-3ba4-41b2-b568-a394025c6c76"}}}]}, {"uuid": "a05f7e5d-2673-4d13-a1c9-eef49f17ca26", "name": "load_p1rlv19640_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e90f763-682e-4771-976c-9cd736b72133"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6bed2d9c-e8f4-4ae5-a8c9-40896dc8e08e"}}}}, {"uuid": "56027744-baa0-42d5-8b68-edfd1bf583b5", "name": "bd45c2ed-6be0-4f81-bd1e-36effbf40114_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3571348598185444, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7897285261495656, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b736c69d-5be1-415c-a425-ec5654f8f039", "name": "a23be684-93ce-4cd6-becf-d7a52813160e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "56027744-baa0-42d5-8b68-edfd1bf583b5"}}}]}, {"uuid": "592c8ae4-e706-4b2d-a646-93ff39996f17", "name": "load_p1rlv19643_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f0e181a-fa89-4c5d-a1cb-6080f91331da"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b736c69d-5be1-415c-a425-ec5654f8f039"}}}}, {"uuid": "c814fe75-4519-48fa-ad9a-2661876cb633", "name": "1980c37a-587b-4e2b-9f3f-d44f334738a3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3571348598185444, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7897285261495656, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fe957262-5f7c-47d7-90b5-8f04f058c6e9", "name": "75889327-7bc0-4064-96ce-be904f063c04", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c814fe75-4519-48fa-ad9a-2661876cb633"}}}]}, {"uuid": "b694819c-01b7-4cb7-a06a-d517d4bd8c90", "name": "load_p1rlv19643_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f0e181a-fa89-4c5d-a1cb-6080f91331da"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fe957262-5f7c-47d7-90b5-8f04f058c6e9"}}}}, {"uuid": "84877362-3505-4637-8a0a-cdac5d81880b", "name": "e9b04e35-cdbd-4958-a7bb-35daa42ee745_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.354599726773856, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.636709731909327, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50de177e-e986-4594-8655-d4e28e80b481", "name": "3645d95c-8b84-4396-820b-2a6475d87400", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "84877362-3505-4637-8a0a-cdac5d81880b"}}}]}, {"uuid": "de328b1d-637f-4e00-8587-c7674fc4b3e2", "name": "load_p1rlv19645_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7efbb32-55d4-409b-a37f-bf01d0620d40"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50de177e-e986-4594-8655-d4e28e80b481"}}}}, {"uuid": "1c560954-9a26-45dc-824c-d2fd2586fc48", "name": "41a3ab7d-0a41-4f58-b572-b432521ee0df_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.354599726773856, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.636709731909327, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d50067a1-8c81-4f68-954a-fc8fab41c905", "name": "e0e37918-3471-4814-afda-69fb3338c899", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1c560954-9a26-45dc-824c-d2fd2586fc48"}}}]}, {"uuid": "db057238-fe08-440a-8938-d471bbdb491b", "name": "load_p1rlv19645_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7efbb32-55d4-409b-a37f-bf01d0620d40"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d50067a1-8c81-4f68-954a-fc8fab41c905"}}}}, {"uuid": "5cfa9f24-fb2e-49eb-9407-fed20b015f3b", "name": "d379a36f-5756-47b3-8ca0-a98f811e3598_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1763634802125313, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8050824744595734, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5c1a0340-3f57-4656-98ff-967ad63d2363", "name": "73089cdc-992d-4e0e-91de-9f8dea577196", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5cfa9f24-fb2e-49eb-9407-fed20b015f3b"}}}]}, {"uuid": "b5a20c0a-b9dd-4aba-8196-cf6292d1eb80", "name": "load_p1rlv19683_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19894180-0890-4585-b4e2-55500af3c41a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5c1a0340-3f57-4656-98ff-967ad63d2363"}}}}, {"uuid": "20fee792-37d4-4207-9023-dd663ac217a8", "name": "d4b61c7e-2966-4cd3-86b5-207b3da141d7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1763634802125313, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8050824744595734, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a455b71-a883-4b54-abf0-167c0928995b", "name": "4d363972-a584-4fc8-8320-0827e3556b23", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "20fee792-37d4-4207-9023-dd663ac217a8"}}}]}, {"uuid": "36f8c773-9a3e-4bae-b0db-fc25a31d0d23", "name": "load_p1rlv19683_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19894180-0890-4585-b4e2-55500af3c41a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a455b71-a883-4b54-abf0-167c0928995b"}}}}, {"uuid": "98cab855-e394-4444-8423-672ff982150f", "name": "b1b5f5e3-d8d1-4f6f-8b7b-4b1c42aaf35b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7055277650263714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24030088917661724, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a85f6b6-de93-4523-9c7d-1ace1ea283ec", "name": "aae51e6e-b2e7-4c5f-b5d0-d72d3b04a775", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "98cab855-e394-4444-8423-672ff982150f"}}}]}, {"uuid": "2adf5309-aace-4f00-bed6-ed4e7bf836ce", "name": "load_p1rlv37689_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f827fe9e-1ffe-456c-a57b-c3374aef8ad8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0a85f6b6-de93-4523-9c7d-1ace1ea283ec"}}}}, {"uuid": "c87318a7-0a2d-4353-959c-35db301a0857", "name": "2d96a672-ef1f-4027-9e52-530ec682c50e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7055277650263714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24030088917661724, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8ec9c9b7-ab9f-491f-9c1e-32faf27ddc30", "name": "c7f10edc-5d68-4589-89e7-b23d4b7e966b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c87318a7-0a2d-4353-959c-35db301a0857"}}}]}, {"uuid": "858d9eec-d859-4213-9573-c97d163c8c71", "name": "load_p1rlv37689_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f827fe9e-1ffe-456c-a57b-c3374aef8ad8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8ec9c9b7-ab9f-491f-9c1e-32faf27ddc30"}}}}, {"uuid": "86aabb6c-bae3-4a95-8565-6a0e0c767b23", "name": "0404afe2-c99a-439e-bec4-76d53cb6dc65_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.991433457795887, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5982568468826307, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6b10a72c-3057-428c-b0c4-5cd3762cd47c", "name": "623fd40d-3aab-4ef4-96dc-6464c1c13bff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "86aabb6c-bae3-4a95-8565-6a0e0c767b23"}}}]}, {"uuid": "2b4781d6-4030-4d0b-9b8d-26f217c668e9", "name": "load_p1rlv37691_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da3cd593-6f05-41ba-9609-f6f1e307e998"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6b10a72c-3057-428c-b0c4-5cd3762cd47c"}}}}, {"uuid": "5493cb3e-8215-40c5-9d74-817a0fa2af4a", "name": "7dd65da8-bc6e-404d-9358-d414e807e6df_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.991433457795887, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5982568468826307, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b0f43b4f-d9a9-4d34-bf7f-629916a21f88", "name": "c48de185-469d-4a88-bc12-b03777829130", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5493cb3e-8215-40c5-9d74-817a0fa2af4a"}}}]}, {"uuid": "4561c13f-6bf9-4990-a9e7-23a58b2df2e8", "name": "load_p1rlv37691_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da3cd593-6f05-41ba-9609-f6f1e307e998"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b0f43b4f-d9a9-4d34-bf7f-629916a21f88"}}}}, {"uuid": "c77b0fe6-fd6d-423f-9782-f42f4e139504", "name": "3d48ae85-0040-459a-9849-d48248b838ae_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9233060787231575, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.431469772224645, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8b877d53-04ab-4102-874b-cb892fa21f1f", "name": "0011e870-a629-4810-b98a-1dcd94344fa9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c77b0fe6-fd6d-423f-9782-f42f4e139504"}}}]}, {"uuid": "c4eccd81-0ac9-473f-b1b0-50cd3a52c637", "name": "load_p1rlv37703_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01c9efda-0adf-4932-8f54-2938964371d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8b877d53-04ab-4102-874b-cb892fa21f1f"}}}}, {"uuid": "83dfc415-cd1b-40d8-ad51-de06357e06e5", "name": "fbc35b91-860a-4f01-aeea-64536975e4c5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9233060787231575, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.431469772224645, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0691e60b-1d86-4f19-b917-91d72314e28f", "name": "9e6c4158-1c0b-4ddb-917a-70f78209c62b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "83dfc415-cd1b-40d8-ad51-de06357e06e5"}}}]}, {"uuid": "2653101b-973b-4458-840e-2d2e1856bb38", "name": "load_p1rlv37703_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01c9efda-0adf-4932-8f54-2938964371d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0691e60b-1d86-4f19-b917-91d72314e28f"}}}}, {"uuid": "1a073c58-9dd9-412e-a2fa-dff5fafef051", "name": "f58579e3-c492-435b-a453-142e6abb9e9c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5500863393357383, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3576036143879098, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a7e703dd-da55-44a3-9e7c-14d344c4d2fc", "name": "62ec24a3-0acd-41eb-ba42-3ffd327e1896", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1a073c58-9dd9-412e-a2fa-dff5fafef051"}}}]}, {"uuid": "cc3f5d8c-a0ce-49d0-920a-f2fa6fddc0a1", "name": "load_p1rlv37710_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38bda697-2888-467e-bab0-62896a62503f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a7e703dd-da55-44a3-9e7c-14d344c4d2fc"}}}}, {"uuid": "b7358bdb-3dff-4dd8-a8b7-700381fa7043", "name": "ccf907b8-6bd1-45fe-bafe-b26b9ecbaf16_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5500863393357383, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3576036143879098, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "394f38b0-a2d4-48fe-b92e-e2df4d1a8720", "name": "1195b5b4-2083-4043-a818-76e24534b81d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b7358bdb-3dff-4dd8-a8b7-700381fa7043"}}}]}, {"uuid": "534db35e-7b40-4f9d-a0fd-a97b5e54190a", "name": "load_p1rlv37710_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38bda697-2888-467e-bab0-62896a62503f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "394f38b0-a2d4-48fe-b92e-e2df4d1a8720"}}}}, {"uuid": "6f56ae76-1918-43f7-89a3-77b983b8bb29", "name": "b722e849-b111-4203-855b-f505ba11eb7b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2045141672666357, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3046267940472902, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b364fae8-133e-49f4-b5a3-761aad2becc9", "name": "f4ac8e2a-7c9b-4795-959b-cd96e9b89fb5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6f56ae76-1918-43f7-89a3-77b983b8bb29"}}}]}, {"uuid": "9e3f743f-e24d-486d-85ae-927080312cd0", "name": "load_p1rlv37732_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d998a0-628e-4009-a6c8-07af906f6d43"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b364fae8-133e-49f4-b5a3-761aad2becc9"}}}}, {"uuid": "ebe3272a-9772-4c74-876b-eeca1b7cebc0", "name": "6fecf92d-9e03-4f24-9d19-d5a6046488d2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2045141672666357, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3046267940472902, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cc9452be-8e52-4b91-96d8-092b3a3c5c39", "name": "ac7cf685-62c6-47f5-af2f-2c0d68dd981a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ebe3272a-9772-4c74-876b-eeca1b7cebc0"}}}]}, {"uuid": "f94b41ae-f7e2-45a9-8982-d1f2a4c17754", "name": "load_p1rlv37732_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d998a0-628e-4009-a6c8-07af906f6d43"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cc9452be-8e52-4b91-96d8-092b3a3c5c39"}}}}, {"uuid": "c2393e52-03c1-41ff-a32e-c1ac1d17ba93", "name": "776d405b-dd5a-49ab-aeea-98dcac4f6649_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.106965589535082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4202201192794711, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2ee241d8-7db3-4353-858e-63fdc838be4d", "name": "14dad654-46fe-471d-ad8d-bbf20a170c22", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c2393e52-03c1-41ff-a32e-c1ac1d17ba93"}}}]}, {"uuid": "15228525-13a8-4f68-9e9a-afeb20048a91", "name": "load_p1rlv37776_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b24da1e-9a6e-4545-9ad4-a9f0e9675fd1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2ee241d8-7db3-4353-858e-63fdc838be4d"}}}}, {"uuid": "a0ed8fb5-9e42-4c0e-873b-cf78be7f20be", "name": "372a9612-a533-4703-8742-e10f26fd3696_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.106965589535082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4202201192794711, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e80daaf8-3d12-4628-8de2-e4372eedada7", "name": "121fa53a-e7f5-4720-8f34-227d39a96dd8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a0ed8fb5-9e42-4c0e-873b-cf78be7f20be"}}}]}, {"uuid": "306bb777-27dc-416c-96b8-0447cad5164d", "name": "load_p1rlv37776_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b24da1e-9a6e-4545-9ad4-a9f0e9675fd1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e80daaf8-3d12-4628-8de2-e4372eedada7"}}}}, {"uuid": "d93d7ca7-c729-4125-bfd0-2f82fa5a471f", "name": "9fd20af8-340a-405a-9370-74c501099235_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2167250892906645, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5534364726692191, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "734a6bb3-dae1-4e22-be5d-527c73a6540a", "name": "2b66fee4-6134-478a-b846-d39ac761d1b5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d93d7ca7-c729-4125-bfd0-2f82fa5a471f"}}}]}, {"uuid": "a68c442d-21fb-41e6-95df-690b8cd20ab7", "name": "load_p1rlv37778_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5aaed5d-8312-4707-a047-634e433bf49f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "734a6bb3-dae1-4e22-be5d-527c73a6540a"}}}}, {"uuid": "139fc5dd-4ca9-4a4e-82e3-8b80b42bb469", "name": "9c3a510f-8e0a-4448-bc99-f8bae25c5d9f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2167250892906645, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5534364726692191, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "86030c64-9459-40d0-b8e1-71d5ae1714d0", "name": "924ac7c7-beb4-4989-b768-0880dcd98530", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "139fc5dd-4ca9-4a4e-82e3-8b80b42bb469"}}}]}, {"uuid": "e486422a-1d43-4a96-bc12-12ab56910f1a", "name": "load_p1rlv37778_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5aaed5d-8312-4707-a047-634e433bf49f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "86030c64-9459-40d0-b8e1-71d5ae1714d0"}}}}, {"uuid": "74ee0370-3552-4051-b115-3d9a4a803ca9", "name": "1d4e7e8d-41c6-4b7c-9fe1-c52d8786e85b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.902887215219663, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.111231385342157, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4bb58eb7-9b1b-49ed-be9f-dd90df587a32", "name": "5255aa2d-5cfc-4751-b610-3faf2f23d324", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "74ee0370-3552-4051-b115-3d9a4a803ca9"}}}]}, {"uuid": "d440d345-0229-4755-b7a7-bd7e8c8d8d62", "name": "load_p1rlv37782_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d7181ee-ef64-4ded-b619-00ac09d55bf5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4bb58eb7-9b1b-49ed-be9f-dd90df587a32"}}}}, {"uuid": "2f33d06a-54a0-48c0-bfcf-aec8a3f39520", "name": "45c722ba-3606-42aa-801a-02dbe9f10be2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.902887215219663, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.111231385342157, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "35d7c016-72d7-473e-b225-83d5a38ed0ad", "name": "086f70d3-b36c-4f63-bbbd-4ecc9a894bab", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2f33d06a-54a0-48c0-bfcf-aec8a3f39520"}}}]}, {"uuid": "5c8f4d9e-dd5b-4d8a-be06-f85681e95b9d", "name": "load_p1rlv37782_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d7181ee-ef64-4ded-b619-00ac09d55bf5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "35d7c016-72d7-473e-b225-83d5a38ed0ad"}}}}, {"uuid": "0e1bf61f-7a87-4871-aa7b-22c7e79ee653", "name": "79649c1e-e16e-4278-89ec-21d847472dda_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9179777962446224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3481400399277513, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a2723ae6-1a19-4f11-bd92-98787ee42be2", "name": "5d77a13a-856c-45bf-8e0f-19b712c6e3a3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0e1bf61f-7a87-4871-aa7b-22c7e79ee653"}}}]}, {"uuid": "8d154921-728c-48a5-b4a7-bcc8c97708bb", "name": "load_p1rlv38046_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10be49a0-301a-4c7e-8ab7-49c14e483079"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a2723ae6-1a19-4f11-bd92-98787ee42be2"}}}}, {"uuid": "ed625f7a-68a1-410e-b8df-84452f66f6b8", "name": "59123853-e958-47af-b720-f91604eef741_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9179777962446224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3481400399277513, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8faee505-53f5-47af-9023-87d9ff1df03b", "name": "9eef8f72-c435-49be-afdb-c937371c9361", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ed625f7a-68a1-410e-b8df-84452f66f6b8"}}}]}, {"uuid": "4af84904-a5e3-4004-9f0c-6ed1b7231689", "name": "load_p1rlv38046_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10be49a0-301a-4c7e-8ab7-49c14e483079"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8faee505-53f5-47af-9023-87d9ff1df03b"}}}}, {"uuid": "1df809e0-3274-4384-9c54-d21577f02b53", "name": "4938b5d6-73b1-485a-9b79-9c1f12c4f1a8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.567401274738218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6497123013243786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5b46ccb1-8f48-4fbc-9c82-e415a0ad9d07", "name": "42eb82be-9e48-4f8c-b18a-eeadcad25a56", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1df809e0-3274-4384-9c54-d21577f02b53"}}}]}, {"uuid": "dfde6f3a-b403-417f-8c61-c644f709f0d3", "name": "load_p1rlv38047_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0935a86b-b9fb-4058-8381-a41f67d6c9dd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5b46ccb1-8f48-4fbc-9c82-e415a0ad9d07"}}}}, {"uuid": "f5f4bd81-a812-4107-ac47-065bed44c722", "name": "fc72493e-0be6-4f75-9cb3-001f243338b0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.567401274738218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6497123013243786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7aee0163-ee99-4c05-95b5-44654457a3cc", "name": "f08bd294-0d21-416b-8f98-1b1cc7cdc5a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f5f4bd81-a812-4107-ac47-065bed44c722"}}}]}, {"uuid": "f4651df5-82c7-4ab0-bd4e-5137e3353b1f", "name": "load_p1rlv38047_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0935a86b-b9fb-4058-8381-a41f67d6c9dd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7aee0163-ee99-4c05-95b5-44654457a3cc"}}}}, {"uuid": "a01cc709-6a93-436c-be8f-404385b978ed", "name": "0341cac6-411d-407b-bb85-f0594adc83fc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7055277650263714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24030088917661724, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "57c21e44-3c60-41c7-bf81-b13fffe7fa16", "name": "cf4d6a99-9857-443c-99c3-64407ec0a059", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a01cc709-6a93-436c-be8f-404385b978ed"}}}]}, {"uuid": "bdfa7b18-fee2-4bf2-9188-13278de4f43f", "name": "load_p1rlv38048_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5da7ff68-5f4c-4d56-88fc-7736df03c0bf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "57c21e44-3c60-41c7-bf81-b13fffe7fa16"}}}}, {"uuid": "f1942386-e836-4587-bcf8-0c1144583744", "name": "896c9f6e-9acb-4270-a40c-35a23d98683d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7055277650263714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24030088917661724, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4227af12-679c-41e9-9c94-3eed1c08f7c6", "name": "a47147a2-c190-4c6e-985d-d08f6c5a3735", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f1942386-e836-4587-bcf8-0c1144583744"}}}]}, {"uuid": "e924c390-81b4-455c-9168-e1bd8492dbef", "name": "load_p1rlv38048_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5da7ff68-5f4c-4d56-88fc-7736df03c0bf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4227af12-679c-41e9-9c94-3eed1c08f7c6"}}}}, {"uuid": "2c6e618c-9bd8-4a23-907b-e1b1054dc113", "name": "45e67a46-945d-46bc-a0e1-2da48c439ab3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3461402320099836, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.810674183062217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4a1be0c9-b577-4e0b-af32-43b02a73f6c3", "name": "71d6dfc0-198c-4a85-bcd4-d01618dd45d9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2c6e618c-9bd8-4a23-907b-e1b1054dc113"}}}]}, {"uuid": "1ad5c597-4a47-4353-9489-946f00e9c421", "name": "load_p1rlv38050_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cafc6c03-240d-499d-a3d8-983b554dd007"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4a1be0c9-b577-4e0b-af32-43b02a73f6c3"}}}}, {"uuid": "f4508784-7f40-4dc9-ad9d-315d99b5c956", "name": "2d00b450-e4c5-4f89-b86e-a120c04dcc5c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3461402320099836, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.810674183062217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "302ac0e1-a6d5-4edc-9313-27fe87f5939b", "name": "9dd76531-cda9-4ed8-a169-0315ae4c992e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f4508784-7f40-4dc9-ad9d-315d99b5c956"}}}]}, {"uuid": "cf8abd4e-54cb-4645-9afe-f58ba3325547", "name": "load_p1rlv38050_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cafc6c03-240d-499d-a3d8-983b554dd007"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "302ac0e1-a6d5-4edc-9313-27fe87f5939b"}}}}, {"uuid": "2db1953f-8ac5-4836-9b25-02934a423246", "name": "3fefc103-bd15-49d7-87e5-56ada79cf4ce_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5229589832640044, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3359880712066463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3a6e37bd-3209-44ad-9074-aa81b0812b1d", "name": "324d4778-60b7-42fc-9066-ef23bde6e01f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2db1953f-8ac5-4836-9b25-02934a423246"}}}]}, {"uuid": "14f17525-bfe4-475a-a678-6316279102a6", "name": "load_p1rlv38052_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9db6122d-1e51-46ac-9cea-ac436e189cd8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3a6e37bd-3209-44ad-9074-aa81b0812b1d"}}}}, {"uuid": "00387573-1e1f-4645-9f4f-ec988a7e403d", "name": "fc70e151-175c-4ed3-b3d0-797ba65b6651_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5229589832640044, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3359880712066463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7df7a2f1-c087-4459-b464-df267e33d2ac", "name": "0170b546-2ac5-4288-bcaf-bbd96c66050c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "00387573-1e1f-4645-9f4f-ec988a7e403d"}}}]}, {"uuid": "aa000fe1-41ac-4646-98a4-d4d129240649", "name": "load_p1rlv38052_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9db6122d-1e51-46ac-9cea-ac436e189cd8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7df7a2f1-c087-4459-b464-df267e33d2ac"}}}}, {"uuid": "ddba05ec-071b-41c5-8bb7-5c3b8a924a32", "name": "4d7fe478-3369-4513-8f00-61cbffbd24de_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6912886909314806, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4972799611827758, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "49edfd08-7cb8-48ad-97ae-f3c8d7f24eae", "name": "069b9506-9dda-4954-a57a-b0e605bcff0b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ddba05ec-071b-41c5-8bb7-5c3b8a924a32"}}}]}, {"uuid": "37ee0175-44d4-4a8b-b904-22f3be239243", "name": "load_p1rlv38414_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a25b3511-86cf-404e-944f-273d3f94c05a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "49edfd08-7cb8-48ad-97ae-f3c8d7f24eae"}}}}, {"uuid": "72dc9b8f-422e-469c-8384-57ec67ffd3dd", "name": "178b63c7-ed29-45ce-b987-87d42a938880_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6912886909314806, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4972799611827758, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e05fa500-dcfe-4eb0-a404-e10a89b8bfb5", "name": "8f8ed8fa-059c-467b-919c-368f708c9254", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72dc9b8f-422e-469c-8384-57ec67ffd3dd"}}}]}, {"uuid": "03aafef1-9f4a-40c0-ab85-7f1c8f3ca2d4", "name": "load_p1rlv38414_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a25b3511-86cf-404e-944f-273d3f94c05a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e05fa500-dcfe-4eb0-a404-e10a89b8bfb5"}}}}, {"uuid": "922dde16-f073-4cba-89cd-a40353cca45c", "name": "ebf5b4b2-e731-4331-be5b-f322820089ad_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6878718453957338, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9600190343762964, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8cebfff3-32a0-4c4c-a852-dfa1f641987d", "name": "bda622e7-45b3-4ff7-867c-481d3a79b9c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "922dde16-f073-4cba-89cd-a40353cca45c"}}}]}, {"uuid": "51a15ddd-7db2-4da1-a796-936153825f09", "name": "load_p1rlv38417_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "201112bb-3dc7-4a15-9af6-155626ac1ae5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8cebfff3-32a0-4c4c-a852-dfa1f641987d"}}}}, {"uuid": "2c8a9662-1226-4af2-aecf-f8cd908d8f43", "name": "22ef792c-56e0-4d18-9df7-f59e6a870b97_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6878718453957338, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9600190343762964, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1605947c-01ca-43fe-af9e-54f7a5d541dc", "name": "26506bde-e643-4406-af63-c70ff8a8c062", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2c8a9662-1226-4af2-aecf-f8cd908d8f43"}}}]}, {"uuid": "e24cf5b6-9e5c-424f-9d57-f2710d51ee80", "name": "load_p1rlv38417_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "201112bb-3dc7-4a15-9af6-155626ac1ae5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1605947c-01ca-43fe-af9e-54f7a5d541dc"}}}}, {"uuid": "40bee9c3-6f8e-4820-9b82-c561e4dd8cd5", "name": "b3e8f28b-546c-4b70-ae2f-cbfd56534bb2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1e9537dc-a42d-4f9d-82f4-d287f4a35c2f", "name": "d1e6d7cd-2d4c-443f-a229-feddf0d9f0f7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "40bee9c3-6f8e-4820-9b82-c561e4dd8cd5"}}}]}, {"uuid": "00fe2b7b-033a-492a-8759-3b3af439d698", "name": "load_p1rlv38419_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6e4595c-0ad9-4501-b86f-c559917d4b86"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1e9537dc-a42d-4f9d-82f4-d287f4a35c2f"}}}}, {"uuid": "4b9d5d48-e313-4aaa-b53d-24fccd78187f", "name": "a2179bea-f33a-48c1-bc9f-61ae16e84437_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6e0f2455-0479-4f0c-a49f-27a274acd027", "name": "e69754bc-3284-4f21-aca4-5b9887bc5486", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4b9d5d48-e313-4aaa-b53d-24fccd78187f"}}}]}, {"uuid": "679b326d-63be-4613-8983-a59fc0fa4c32", "name": "load_p1rlv38419_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6e4595c-0ad9-4501-b86f-c559917d4b86"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6e0f2455-0479-4f0c-a49f-27a274acd027"}}}}, {"uuid": "5e332f41-3784-41b1-bdd5-1b456b231b94", "name": "223ee756-b983-49a0-a8d7-5da73d7a9854_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4437884187508536, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6647073432497462, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "08881b61-ad46-4516-8ea2-fd49b9927b0d", "name": "207cf4ad-47c0-4517-9b0a-4cff9241790a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5e332f41-3784-41b1-bdd5-1b456b231b94"}}}]}, {"uuid": "8e95af66-31ca-450a-9aca-8e106892bc76", "name": "load_p1rlv38535_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0764c32-4f46-473a-9a72-cccc45ae28d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "08881b61-ad46-4516-8ea2-fd49b9927b0d"}}}}, {"uuid": "f31c8764-bc97-4b4f-9cde-1bff89246fc5", "name": "9a7854f0-9599-41e2-9500-3224aa894639_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4437884187508536, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6647073432497462, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ca22f49a-9bb5-4730-9763-f1547662a06c", "name": "31ed3613-f5be-4a5d-8fd7-4c68c8981c8f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f31c8764-bc97-4b4f-9cde-1bff89246fc5"}}}]}, {"uuid": "58393dd1-90b2-4398-bbe7-3f69c8f25e00", "name": "load_p1rlv38535_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0764c32-4f46-473a-9a72-cccc45ae28d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ca22f49a-9bb5-4730-9763-f1547662a06c"}}}}, {"uuid": "d454f0ed-1569-430e-a940-9d11311f731b", "name": "f04f697d-37ba-4d73-95d1-f96a5f7ecc37_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5614762943111877, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5370528430833497, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d0dc1e81-ba82-445e-b840-c4eb3368537d", "name": "65336003-5aff-4e73-9c30-20dfe7f3ad78", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d454f0ed-1569-430e-a940-9d11311f731b"}}}]}, {"uuid": "d8642f17-a073-4fc4-b101-e1bde0153ea3", "name": "load_p1rlv38536_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ff930f9-63f0-4cab-b74a-3db7eb99f9eb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d0dc1e81-ba82-445e-b840-c4eb3368537d"}}}}, {"uuid": "5f99d8e8-222c-428c-b58d-bedefaed8cff", "name": "34fb25d7-73ca-40bd-a16e-924046d35039_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5614762943111877, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5370528430833497, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7717126d-86db-447c-b9ee-e99387684c27", "name": "7a840a3c-59e7-403f-850b-0ed4f56e8cda", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5f99d8e8-222c-428c-b58d-bedefaed8cff"}}}]}, {"uuid": "f132d970-074f-4152-9cf2-133e45e0e521", "name": "load_p1rlv38536_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ff930f9-63f0-4cab-b74a-3db7eb99f9eb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7717126d-86db-447c-b9ee-e99387684c27"}}}}, {"uuid": "70674b72-a9af-4244-a49c-a946d23cd5d4", "name": "bceb8436-c19d-430a-8583-8e705606fc45_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.025577912376512, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6479907691217454, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4b2e37ea-aabf-48dc-8e2b-7f18d626f96c", "name": "e3309c21-0a36-47e8-86bb-7cc362d97460", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "70674b72-a9af-4244-a49c-a946d23cd5d4"}}}]}, {"uuid": "80296163-decf-4c33-9c29-f346c1e8894b", "name": "load_p1rlv38638_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a3851f7-2dd3-447b-918f-7a8c954f21d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4b2e37ea-aabf-48dc-8e2b-7f18d626f96c"}}}}, {"uuid": "5f88a3fa-aabe-40f5-98e8-b4c86b5127f2", "name": "14f0875b-323b-4763-accf-cc6bcf457c6a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.025577912376512, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6479907691217454, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "821814a0-8f88-41d6-833d-160deb4cc4d3", "name": "ecc2ace6-5ab0-40de-9f3b-4ca05e791e59", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5f88a3fa-aabe-40f5-98e8-b4c86b5127f2"}}}]}, {"uuid": "23e8e6e7-c753-4b47-b081-311d3606c52a", "name": "load_p1rlv38638_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a3851f7-2dd3-447b-918f-7a8c954f21d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "821814a0-8f88-41d6-833d-160deb4cc4d3"}}}}, {"uuid": "e0395ca4-5b57-46fa-a42b-a3439c90eed9", "name": "6be7f68a-6e69-4489-b82d-f3b9a8918363_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9441129975170507, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3957038740694923, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f9262875-977b-478e-9cf8-77465f491ce9", "name": "6be7f68a-6e69-4489-b82d-f3b9a8918363_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9441129975170507, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3957038740694923, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8ff257d5-f8f4-44d2-bef4-ea55e776524c", "name": "6be7f68a-6e69-4489-b82d-f3b9a8918363_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9441129975170507, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3957038740694923, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "636fdd99-94b2-4fd8-92ef-dd9197f93ae7", "name": "e70df2d2-9cd0-4d1a-944e-4f0ab30a0962", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e0395ca4-5b57-46fa-a42b-a3439c90eed9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f9262875-977b-478e-9cf8-77465f491ce9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ff257d5-f8f4-44d2-bef4-ea55e776524c"}}}]}, {"uuid": "e184e575-2f3d-45e6-be66-31e4057bd428", "name": "load_p1rlv12518", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72f659b6-d302-4887-a2f6-1a477ad3324c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "636fdd99-94b2-4fd8-92ef-dd9197f93ae7"}}}}, {"uuid": "c5214aa9-c215-401b-9460-cc4c162c5548", "name": "b3583558-bd86-450e-bf77-a42b5aedf621_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3777678420633588, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24446119545004893, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0735b653-7b01-4570-a36e-ceb8ba68e689", "name": "b3583558-bd86-450e-bf77-a42b5aedf621_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3777678420633588, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24446119545004893, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ea3aef81-1188-4650-b68c-5f1a6b83a171", "name": "b3583558-bd86-450e-bf77-a42b5aedf621_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3777678420633588, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24446119545004893, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "afe2c2f2-60ae-474a-84c9-2fb36790d4c8", "name": "26e5f4ef-16f1-46f8-9a3e-9b9ceea7fc24", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c5214aa9-c215-401b-9460-cc4c162c5548"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0735b653-7b01-4570-a36e-ceb8ba68e689"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ea3aef81-1188-4650-b68c-5f1a6b83a171"}}}]}, {"uuid": "f2fb4ebc-698b-4e4f-81b1-6f918e58f23b", "name": "load_p1rlv12528", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9660b80-0fce-4be4-b541-743d5811133c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "afe2c2f2-60ae-474a-84c9-2fb36790d4c8"}}}}, {"uuid": "d799aa9a-afa6-40bc-be59-538d75cef5f6", "name": "e4ebfcf1-30b4-48e9-846b-9c02955861b4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5605855582192873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.02826560468920274, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b12c6d01-4460-4311-a904-c5d13143e75b", "name": "e4ebfcf1-30b4-48e9-846b-9c02955861b4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5605855582192873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.02826560468920274, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "37ef4d0b-b249-4220-a095-69f148aae9ad", "name": "e4ebfcf1-30b4-48e9-846b-9c02955861b4_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5605855582192873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.02826560468920274, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e482f27d-250f-4b0d-8721-098972b804e9", "name": "ca91ac77-bba4-4c41-bf16-c13e29e3f08d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d799aa9a-afa6-40bc-be59-538d75cef5f6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b12c6d01-4460-4311-a904-c5d13143e75b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "37ef4d0b-b249-4220-a095-69f148aae9ad"}}}]}, {"uuid": "c339ffc7-6711-43e4-a6ff-fd769736859f", "name": "load_p1rlv12534", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8796d817-aad6-4d22-b3d4-baf8a686c9df"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e482f27d-250f-4b0d-8721-098972b804e9"}}}}, {"uuid": "a89241f1-f525-4741-95f7-15ebe25f2bf7", "name": "ef38231c-6604-44b3-8ec3-f055074b9f60_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.424752506471074, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.0314252036301887, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "908dbfa2-35f6-4640-9846-29f2d49780b9", "name": "ef38231c-6604-44b3-8ec3-f055074b9f60_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.424752506471074, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.0314252036301887, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "777d5c0c-a10b-4048-97cf-3f3b8987e260", "name": "ef38231c-6604-44b3-8ec3-f055074b9f60_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.424752506471074, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.0314252036301887, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "980ad2f3-5855-4bdc-a897-8daa2e64c474", "name": "136af5b7-a726-451f-900a-e124c28ab761", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a89241f1-f525-4741-95f7-15ebe25f2bf7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "908dbfa2-35f6-4640-9846-29f2d49780b9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "777d5c0c-a10b-4048-97cf-3f3b8987e260"}}}]}, {"uuid": "a74387f0-d972-424b-a0e5-b02d4661ba19", "name": "load_p1rlv12536", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e89452f3-ce44-46d3-a259-f66044e01c2c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "980ad2f3-5855-4bdc-a897-8daa2e64c474"}}}}, {"uuid": "9fa1b332-67ae-4b1c-b3e6-f7a01d4f4309", "name": "e72d8412-519c-4c9b-91b4-d30cabeed95e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0622945809345516, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23624651294541713, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "29f0f8e2-d893-4275-8fee-fc83bc3daa0f", "name": "e72d8412-519c-4c9b-91b4-d30cabeed95e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0622945809345516, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23624651294541713, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c5aa709c-3d6e-4efe-be9c-b404f5629251", "name": "e72d8412-519c-4c9b-91b4-d30cabeed95e_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0622945809345516, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23624651294541713, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5629edce-626f-4f5b-b520-c93cfdc3cc70", "name": "3e0e46c7-cb9f-493c-aa0d-20896a8d1c74", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9fa1b332-67ae-4b1c-b3e6-f7a01d4f4309"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "29f0f8e2-d893-4275-8fee-fc83bc3daa0f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c5aa709c-3d6e-4efe-be9c-b404f5629251"}}}]}, {"uuid": "930c0be3-c6a4-412b-beaf-86f6ec4e901e", "name": "load_p1rlv12985", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df3aae83-f4b0-4db2-9301-dff1664ac23e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5629edce-626f-4f5b-b520-c93cfdc3cc70"}}}}, {"uuid": "ddcd9421-d4d4-4ef3-9f27-f7b5eb64edb3", "name": "24b8b12b-5d1b-46af-a09c-026c4839e859_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.23597191427304684, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09897102743265196, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "379f3f51-cca1-443a-a710-48a9a2856435", "name": "24b8b12b-5d1b-46af-a09c-026c4839e859_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.23597191427304684, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09897102743265196, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ca194c22-8ad4-4093-9b0a-df28ce7dc6d2", "name": "24b8b12b-5d1b-46af-a09c-026c4839e859_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.23597191427304684, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09897102743265196, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8cbaefc5-2d8b-49c8-9e44-885cf1424ae4", "name": "d9bbcea0-08b6-43e9-a41d-40b6878a1638", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ddcd9421-d4d4-4ef3-9f27-f7b5eb64edb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "379f3f51-cca1-443a-a710-48a9a2856435"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ca194c22-8ad4-4093-9b0a-df28ce7dc6d2"}}}]}, {"uuid": "d5cde358-4af8-4e17-9e0a-74099ddb837c", "name": "load_p1rlv16411", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ed6276c-a57b-40be-a1f1-34aaaba0ac28"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8cbaefc5-2d8b-49c8-9e44-885cf1424ae4"}}}}, {"uuid": "75af38b7-bb56-4c47-8f76-f921a8286af9", "name": "77502651-0c93-4d82-9ec9-c1e25cf5e25a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7828407995320632, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7683556122374539, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "547c1fb1-1e21-43de-9124-e75a72e23d31", "name": "77502651-0c93-4d82-9ec9-c1e25cf5e25a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7828407995320632, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7683556122374539, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6a9f4749-ed1a-46fc-8dfa-46c60b940f65", "name": "77502651-0c93-4d82-9ec9-c1e25cf5e25a_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7828407995320632, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7683556122374539, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "90cea8c6-e1fc-4a53-9a62-fbb951d13dc3", "name": "c35e4979-a43e-4803-a90a-5d57dbc220f7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "75af38b7-bb56-4c47-8f76-f921a8286af9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "547c1fb1-1e21-43de-9124-e75a72e23d31"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6a9f4749-ed1a-46fc-8dfa-46c60b940f65"}}}]}, {"uuid": "92d8cb69-f945-46f1-8d83-82c2569dbeb0", "name": "load_p1rlv18169", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c1eac45-623a-4f0a-874d-a4b56a8e2ea7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "90cea8c6-e1fc-4a53-9a62-fbb951d13dc3"}}}}, {"uuid": "75109933-e360-431a-ae56-6a8713fb4e4f", "name": "0c352d6e-62c5-4ca5-aa5f-694c59a9bde2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7765583938143562, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2953468263898592, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "52932e4b-3f68-4d39-9cdf-6831b48e90a2", "name": "0c352d6e-62c5-4ca5-aa5f-694c59a9bde2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7765583938143562, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2953468263898592, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ce695ebd-ff35-4c4e-8193-4b63fcbae6ad", "name": "0c352d6e-62c5-4ca5-aa5f-694c59a9bde2_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7765583938143562, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2953468263898592, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fa9731e1-8866-4fab-8d71-5c264f3aa4a3", "name": "ceabf2fd-a4fe-49a3-b040-998bc449584e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "75109933-e360-431a-ae56-6a8713fb4e4f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "52932e4b-3f68-4d39-9cdf-6831b48e90a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ce695ebd-ff35-4c4e-8193-4b63fcbae6ad"}}}]}, {"uuid": "7a8af673-1f29-42b4-bdc1-b854078775d7", "name": "load_p1rlv18194", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "949f4cce-f321-4bf0-830b-489edc9964c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fa9731e1-8866-4fab-8d71-5c264f3aa4a3"}}}}, {"uuid": "9387af20-49dd-475f-8324-8380a627105a", "name": "f3505cd8-102f-4866-a8e6-83220722e696_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3791309816618758, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4243669985282459, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "68b9e4ad-9706-461f-a964-bdf6fbec6b39", "name": "f3505cd8-102f-4866-a8e6-83220722e696_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3791309816618758, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4243669985282459, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5767b6a3-e20f-4fb6-b4e9-f280bf9623f1", "name": "f3505cd8-102f-4866-a8e6-83220722e696_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3791309816618758, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4243669985282459, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c78d81df-08be-4abd-8543-ba1e3bc71ced", "name": "540ed8e3-c387-4cc6-a726-b7aa52ff1f02", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9387af20-49dd-475f-8324-8380a627105a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "68b9e4ad-9706-461f-a964-bdf6fbec6b39"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5767b6a3-e20f-4fb6-b4e9-f280bf9623f1"}}}]}, {"uuid": "92845255-cba9-4f50-9388-b5806893844f", "name": "load_p1rlv18201", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ead37cb8-af1e-4a46-9466-6ff298b7f8b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c78d81df-08be-4abd-8543-ba1e3bc71ced"}}}}, {"uuid": "66e107e0-5a8d-442d-af88-d909e6806c1d", "name": "cfed4f37-a7eb-470e-9e6e-7429c56af142_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.969330641054165, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5731466084062546, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "788ad97c-109f-4389-8ab7-e5d1aa18711d", "name": "cfed4f37-a7eb-470e-9e6e-7429c56af142_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.969330641054165, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5731466084062546, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1a1efbec-cf76-4c1f-b9d1-8e1f4f40f85f", "name": "cfed4f37-a7eb-470e-9e6e-7429c56af142_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.969330641054165, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5731466084062546, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eb130b96-b1a6-4ad9-92bb-f7c950649d87", "name": "bb4f4ca4-46cc-4d38-974c-bdc47816551a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "66e107e0-5a8d-442d-af88-d909e6806c1d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "788ad97c-109f-4389-8ab7-e5d1aa18711d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1a1efbec-cf76-4c1f-b9d1-8e1f4f40f85f"}}}]}, {"uuid": "1d20a067-0c6f-4dd1-96ae-00fbe68df8be", "name": "load_p1rlv20414", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0a92e79-0ca2-4a10-9050-9e8d7442b019"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eb130b96-b1a6-4ad9-92bb-f7c950649d87"}}}}, {"uuid": "c3167d2e-7abd-4ec9-b7db-189aa1ce6350", "name": "d7a5cbb2-952d-451b-a9c5-797b0d94e7f3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.231046440619022, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3410918425021952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82f1e837-f7ff-45a7-99cd-9947a49f530b", "name": "d7a5cbb2-952d-451b-a9c5-797b0d94e7f3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.231046440619022, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3410918425021952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b62f9ca8-ad3c-458e-8c6c-329a36d278d6", "name": "d7a5cbb2-952d-451b-a9c5-797b0d94e7f3_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.231046440619022, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3410918425021952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "80fd6578-bbee-4566-9069-5278cad9984b", "name": "d76b08ad-4f91-4cda-9fc7-106a67597cb1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c3167d2e-7abd-4ec9-b7db-189aa1ce6350"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "82f1e837-f7ff-45a7-99cd-9947a49f530b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b62f9ca8-ad3c-458e-8c6c-329a36d278d6"}}}]}, {"uuid": "0f1e4fed-f27c-407f-bb1b-0a713223b7c4", "name": "load_p1rlv20501", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cebe1b53-cca6-4bd4-a9f0-616ffb9750b3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "80fd6578-bbee-4566-9069-5278cad9984b"}}}}, {"uuid": "d452202d-9209-43e3-9f1b-676ca771bf58", "name": "b438d550-9204-4deb-b624-2af3f3f95abf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.718035027374153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.747804250682338, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e61ddcce-02b6-49db-8ac0-51d03bffec33", "name": "153d6d88-fe56-4daa-8fe9-2cc8ef339106", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d452202d-9209-43e3-9f1b-676ca771bf58"}}}]}, {"uuid": "742d6d8b-18ae-42cc-9249-c8f8e8f4f378", "name": "load_p1rlv183_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3df778b4-e60b-4e17-b24b-67742d090f42"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e61ddcce-02b6-49db-8ac0-51d03bffec33"}}}}, {"uuid": "50a6d660-3a31-481e-a6c6-f9690dbb7ca1", "name": "ea228642-f5c5-468e-a9dd-409a56d9f874_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.718035027374153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.747804250682338, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8bda7891-b82b-426f-b18c-5eb0fb925fd2", "name": "10d93e0c-b904-4504-aacd-b5f5838c6695", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "50a6d660-3a31-481e-a6c6-f9690dbb7ca1"}}}]}, {"uuid": "48054bdd-5552-4b5b-be40-7d539c24e9dd", "name": "load_p1rlv183_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3df778b4-e60b-4e17-b24b-67742d090f42"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8bda7891-b82b-426f-b18c-5eb0fb925fd2"}}}}, {"uuid": "c2546b6f-fccd-47a4-b41a-52ade98419c7", "name": "a75381a0-7cd8-4979-84c6-33a9b055fcfa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.127855103696037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.9003395103499228, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4e801885-fc8b-44e6-8cff-8ca4ce49e685", "name": "4d068117-da86-4eb2-98b5-8795e125680a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c2546b6f-fccd-47a4-b41a-52ade98419c7"}}}]}, {"uuid": "c8e3ab78-fc66-4999-a4a3-9f6f6034ea51", "name": "load_p1rlv184_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42ca8327-5dcc-415a-820c-ef6ec038b3d8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4e801885-fc8b-44e6-8cff-8ca4ce49e685"}}}}, {"uuid": "66861fae-18d4-4b12-89f9-a42a505c43fe", "name": "f1233123-1f28-4f98-a380-9a86a8c78985_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.127855103696037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.9003395103499228, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2c03d88e-748c-47a3-b381-2286aeb0abd2", "name": "6f60df77-8937-41d3-b043-9b28c08007c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "66861fae-18d4-4b12-89f9-a42a505c43fe"}}}]}, {"uuid": "db648879-6a88-469a-b3ad-bab23c777335", "name": "load_p1rlv184_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42ca8327-5dcc-415a-820c-ef6ec038b3d8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2c03d88e-748c-47a3-b381-2286aeb0abd2"}}}}, {"uuid": "344cdbb3-a80c-404d-9261-eab3f95c614f", "name": "9c4438d4-ff81-4106-afbc-33f8775b30ce_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.1997144025033135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.11221312599546865, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "83102fd9-ad7e-4a54-8f3b-de4b3131ce41", "name": "6e16813c-5d8c-4a79-810c-0c69e27021cc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "344cdbb3-a80c-404d-9261-eab3f95c614f"}}}]}, {"uuid": "958e832c-6fa1-49f6-b718-480453e9d335", "name": "load_p1rlv190_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33b6400e-c84e-43cf-b254-99f946e5a308"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "83102fd9-ad7e-4a54-8f3b-de4b3131ce41"}}}}, {"uuid": "51739107-d681-47db-a519-530a5d81e380", "name": "81398e9c-c69f-44f1-ae1f-52bf38236f43_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.1997144025033135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.11221312599546865, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4ce391b4-aef8-4ab8-918f-0b278f46c29c", "name": "e6cd5f06-51c1-4e78-a54c-b363b90f918e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "51739107-d681-47db-a519-530a5d81e380"}}}]}, {"uuid": "f5fc5e6d-4a64-4320-b5f3-efa23416a9d2", "name": "load_p1rlv190_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33b6400e-c84e-43cf-b254-99f946e5a308"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4ce391b4-aef8-4ab8-918f-0b278f46c29c"}}}}, {"uuid": "f9119206-6129-4831-af07-d5ed4b642c85", "name": "e8661d29-1ea4-4741-ad74-bd78340ddd97_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.549201052937441, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.4274432384427707, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "71a46f8f-842d-4937-a801-10ae42b24e5f", "name": "6a3d3aef-865d-46e9-a960-161498a719fe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f9119206-6129-4831-af07-d5ed4b642c85"}}}]}, {"uuid": "81c21836-45b0-4154-82ae-266770c938c2", "name": "load_p1rlv193_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84223c1b-69e4-4ebc-8274-8706bb412780"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "71a46f8f-842d-4937-a801-10ae42b24e5f"}}}}, {"uuid": "58f983e5-4e84-49bc-91b5-e3a89fdfa15b", "name": "c5f60dda-40d2-4501-b095-c3a416842481_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.549201052937441, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.4274432384427707, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "64473a35-4b5a-4b3b-9df1-622a7c2e80f0", "name": "6eb521f5-3493-4631-9d8e-09e4fdf20bb4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58f983e5-4e84-49bc-91b5-e3a89fdfa15b"}}}]}, {"uuid": "30dac874-159f-460d-82b9-04974e73e308", "name": "load_p1rlv193_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84223c1b-69e4-4ebc-8274-8706bb412780"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "64473a35-4b5a-4b3b-9df1-622a7c2e80f0"}}}}, {"uuid": "a628d381-76e4-40cf-bc24-857e04147606", "name": "22ff9d9d-ac24-4905-9832-998eae8c6b4e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.052819039029729, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6406126314043256, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "45fd4d14-39df-4fa4-b612-a444a80083df", "name": "e5b3eba3-131f-4d1b-ac25-750cf0a4f239", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a628d381-76e4-40cf-bc24-857e04147606"}}}]}, {"uuid": "5557aa36-6bc2-494a-8072-27bd794500fb", "name": "load_p1rlv202_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "de2366e4-30da-429a-82b9-c0ef27eeab47"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "45fd4d14-39df-4fa4-b612-a444a80083df"}}}}, {"uuid": "23222d19-9d59-45d2-a78d-58fc93fd5c6a", "name": "73133d72-263e-4d0d-987b-43979afa5ec3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.052819039029729, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6406126314043256, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "18272da0-9eb7-4022-ba19-f26531774504", "name": "51166873-b93f-4926-9e62-57215002bd49", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "23222d19-9d59-45d2-a78d-58fc93fd5c6a"}}}]}, {"uuid": "ce162529-8696-48ac-a532-4fcc622d5dcd", "name": "load_p1rlv202_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "de2366e4-30da-429a-82b9-c0ef27eeab47"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "18272da0-9eb7-4022-ba19-f26531774504"}}}}, {"uuid": "d11e80ed-46b6-44dd-afc2-5a36e25a5ea6", "name": "7b83fc9d-61ee-4397-8667-a8588c3bc7c9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 10.312489622510887, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5278845211341558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "86764a50-118f-4ae0-904c-3eb7d9149897", "name": "a56124cc-b228-47df-b16e-25063ca6be04", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d11e80ed-46b6-44dd-afc2-5a36e25a5ea6"}}}]}, {"uuid": "a54e9ee0-d987-4d48-8ca7-d8104322c7c8", "name": "load_p1rlv204_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d663fcdc-6c67-4bc9-99ed-12439f75804f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "86764a50-118f-4ae0-904c-3eb7d9149897"}}}}, {"uuid": "57c0a953-1df6-4ccd-bc63-5a6de34ae501", "name": "48bffe9b-9342-4db0-9ae8-708b0d958dc6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 10.312489622510887, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5278845211341558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "99a56edd-9cc3-431a-8528-a4b629d07122", "name": "c8f70a44-fc85-4b43-84d4-1d98126976c7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "57c0a953-1df6-4ccd-bc63-5a6de34ae501"}}}]}, {"uuid": "f5df41fa-acf8-47b6-87fa-8f483834918a", "name": "load_p1rlv204_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d663fcdc-6c67-4bc9-99ed-12439f75804f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "99a56edd-9cc3-431a-8528-a4b629d07122"}}}}, {"uuid": "63d5acfc-0745-4111-8177-dd66ae09918b", "name": "8d4d1bae-d8e2-4947-998e-f570b1a6b343_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9264329962341185, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3633013910451994, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "54707afb-12f1-4423-950c-81e7e8b8cb3d", "name": "461691a0-b77c-4154-a045-49dcb5767ddc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "63d5acfc-0745-4111-8177-dd66ae09918b"}}}]}, {"uuid": "0db73d3b-1367-4883-92fb-b35b5fe61489", "name": "load_p1rlv206_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90aa0d14-285a-4468-bbde-8d76f65b1780"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "54707afb-12f1-4423-950c-81e7e8b8cb3d"}}}}, {"uuid": "cafb2fa3-b0e4-42e8-b518-09654adfe279", "name": "0cfa0843-e053-415d-9e17-f093387d41dc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9264329962341185, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3633013910451994, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9f52038c-27b1-4970-ae57-228257c9bf35", "name": "76c3855d-0b8d-4cb8-9027-5eb6091bd9a4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cafb2fa3-b0e4-42e8-b518-09654adfe279"}}}]}, {"uuid": "ab252666-2ea9-4e1c-aa7a-e49d13cad5fe", "name": "load_p1rlv206_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90aa0d14-285a-4468-bbde-8d76f65b1780"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9f52038c-27b1-4970-ae57-228257c9bf35"}}}}, {"uuid": "0e86c524-7124-441d-8f10-66f45ed36a68", "name": "8ba30a99-87f5-446e-ace9-b55d7af9360b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.495920496244223, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.518490967551786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "239be45a-d09b-44fb-9a2b-b33b6edd3876", "name": "6e0cfa39-9b52-47ac-87fe-e50f8b5afb6c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0e86c524-7124-441d-8f10-66f45ed36a68"}}}]}, {"uuid": "dadd83f6-5ccf-4bac-ab6f-cae797485027", "name": "load_p1rlv207_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6627102c-4524-4e69-bb4d-5b93226df412"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "239be45a-d09b-44fb-9a2b-b33b6edd3876"}}}}, {"uuid": "9ab22791-181c-4d6f-9cc0-3b61593d3e1d", "name": "ffba4d1d-3ac4-4596-8520-a1ba07ae099e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.495920496244223, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.518490967551786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b22fe0e0-baee-4fe0-b605-ddd37c2ffc6a", "name": "4c32cfe6-8a80-42a6-8417-c3d18f08fcac", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9ab22791-181c-4d6f-9cc0-3b61593d3e1d"}}}]}, {"uuid": "4775bbae-5798-4601-a801-b706bf2c4ee6", "name": "load_p1rlv207_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6627102c-4524-4e69-bb4d-5b93226df412"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b22fe0e0-baee-4fe0-b605-ddd37c2ffc6a"}}}}, {"uuid": "cbc3c1e0-4de2-487d-9596-35203ed448d3", "name": "7f5018a1-d799-4607-bdb7-1808ad52c298_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.1298927880171155, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3569806362972607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eb992e66-c752-4374-a1e0-6b6209cd65af", "name": "f42b3cc4-474a-4489-9d4b-4eec13d43e4b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cbc3c1e0-4de2-487d-9596-35203ed448d3"}}}]}, {"uuid": "925eea4e-1656-49bf-8ff1-d56eb17907ab", "name": "load_p1rlv212_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a982feac-5730-4fe0-a1b8-25c06b36e3b0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eb992e66-c752-4374-a1e0-6b6209cd65af"}}}}, {"uuid": "4154954c-7a18-456b-8622-52f9c2893e7c", "name": "69490a8c-b272-46ef-a77f-31b698c067c7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.1298927880171155, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3569806362972607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f0618bd8-742f-4511-a715-4b51b8f630cb", "name": "90e2596a-5f5a-4214-bd68-9ceaea0de7cf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4154954c-7a18-456b-8622-52f9c2893e7c"}}}]}, {"uuid": "82788e05-b8cc-4374-b70a-1b283d49b619", "name": "load_p1rlv212_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a982feac-5730-4fe0-a1b8-25c06b36e3b0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f0618bd8-742f-4511-a715-4b51b8f630cb"}}}}, {"uuid": "d0f61b3d-9dd8-45cc-b426-9ef0aaac7c1b", "name": "d7e028a1-2a14-4d50-8030-c93bc7628a90_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.583696505537418, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4678810835686954, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "25f54090-d0d6-42d4-b9aa-0b3231c4361b", "name": "082a6d0f-4854-44e3-9719-141d16201519", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d0f61b3d-9dd8-45cc-b426-9ef0aaac7c1b"}}}]}, {"uuid": "0720a126-2cc3-4dc6-af38-58177f078903", "name": "load_p1rlv12687_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "163c3824-6847-4b94-9e81-08f15f4667a1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "25f54090-d0d6-42d4-b9aa-0b3231c4361b"}}}}, {"uuid": "4a209186-c2ca-47e3-91c2-43756ee9d9d1", "name": "eb25abe8-65f1-4081-a59a-54ed4be1f40b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.583696505537418, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4678810835686954, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5df58dd4-8b5e-4767-8d0b-014a76f208cc", "name": "0c67fd09-9f70-4278-b5c3-87ba4c32d4a4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4a209186-c2ca-47e3-91c2-43756ee9d9d1"}}}]}, {"uuid": "587b7bd5-45c9-4d29-a103-1654b7609e31", "name": "load_p1rlv12687_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "163c3824-6847-4b94-9e81-08f15f4667a1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5df58dd4-8b5e-4767-8d0b-014a76f208cc"}}}}, {"uuid": "7c9572f6-3d24-49ce-8e4b-bd40d675d2ff", "name": "24658cf7-3b72-4072-aa99-2aa43e79f68e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.073647835052278, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9870900939844905, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "78dc3bd2-faee-4bfa-a8ad-e73cef6d4bb8", "name": "10dbcd6c-c7d5-4021-8409-dbecd8397b67", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7c9572f6-3d24-49ce-8e4b-bd40d675d2ff"}}}]}, {"uuid": "acd5ef5c-b674-4b1a-bb31-a05b03cac46d", "name": "load_p1rlv12713_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff16aad0-98c1-4563-a844-e0ce909c1a79"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "78dc3bd2-faee-4bfa-a8ad-e73cef6d4bb8"}}}}, {"uuid": "6c8c64d5-8232-48f3-b779-e284a0d79625", "name": "2e710491-6935-4c22-a3fb-03a66154e627_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.073647835052278, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9870900939844905, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f197177b-277e-4088-b0ad-e2d741d93d9f", "name": "b7ff3a42-4e19-4355-b425-f3c12537a70e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c8c64d5-8232-48f3-b779-e284a0d79625"}}}]}, {"uuid": "3f3a20a9-a720-4b31-a158-a8d5a99ac7c5", "name": "load_p1rlv12713_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff16aad0-98c1-4563-a844-e0ce909c1a79"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f197177b-277e-4088-b0ad-e2d741d93d9f"}}}}, {"uuid": "f165255b-c573-44e3-84cd-49783a88ab2e", "name": "1dbad6e5-8c1a-4011-bea1-bff55d509e1c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.717517070184915, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6715744239051029, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "420a0bce-f51c-4b62-8e6b-9a387e86a735", "name": "b4b542a3-23bc-49fe-8b97-9061f3eb79d0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f165255b-c573-44e3-84cd-49783a88ab2e"}}}]}, {"uuid": "18ffffa2-9edd-4b1e-9e65-5b6c6bae3648", "name": "load_p1rlv17006_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b53edd15-5a3e-4b7a-97c4-046582bb4801"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "420a0bce-f51c-4b62-8e6b-9a387e86a735"}}}}, {"uuid": "3a246336-b14b-440f-bc6a-b422db5dbaf9", "name": "eb6052a5-cda9-4e21-bc34-c012cb2a45c9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.717517070184915, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6715744239051029, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "daf286f3-ba08-4a4a-a63b-e2444b88c23b", "name": "34263f6f-fb33-4385-b0da-d5e94b1c7962", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3a246336-b14b-440f-bc6a-b422db5dbaf9"}}}]}, {"uuid": "60052a5b-71bb-4bc8-8e08-ce9093d39625", "name": "load_p1rlv17006_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b53edd15-5a3e-4b7a-97c4-046582bb4801"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "daf286f3-ba08-4a4a-a63b-e2444b88c23b"}}}}, {"uuid": "7b15de94-09be-4c5d-bcad-51da9006d9b8", "name": "4e35b209-fd6d-4c40-8295-c4c03decf7ed_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.232057012168481, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2513317849586886, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a0b81f47-b2c7-481f-b0d6-0a682a1f9e12", "name": "1cd07c6b-4cb5-4c8c-894d-049edc6327bf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b15de94-09be-4c5d-bcad-51da9006d9b8"}}}]}, {"uuid": "062e62cb-fef0-435f-8624-d1ce4dce2226", "name": "load_p1rlv17103_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ff9eb4c-2523-48e0-8490-619d26b9cca4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a0b81f47-b2c7-481f-b0d6-0a682a1f9e12"}}}}, {"uuid": "cf5c4bd5-036b-40d7-b817-cc747db47804", "name": "3052e4cd-e42c-46e4-a14f-22b6800c7106_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.232057012168481, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2513317849586886, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fa3a0152-406c-41d9-823e-8e9d0c488cb3", "name": "7de8fa38-01f0-48ce-bd95-b70f4741c401", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cf5c4bd5-036b-40d7-b817-cc747db47804"}}}]}, {"uuid": "97bbad00-72ba-4f7f-9c82-ae75e91ccf17", "name": "load_p1rlv17103_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ff9eb4c-2523-48e0-8490-619d26b9cca4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fa3a0152-406c-41d9-823e-8e9d0c488cb3"}}}}, {"uuid": "41fbaba5-530d-45c4-8ac2-003cdc444c4b", "name": "2e037faf-fd59-47a0-b8d8-baff8428d902_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2219087879829873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3595087789107823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c00fb412-46d2-4e3b-b892-4c29ed9a96dc", "name": "34327e4c-a3bf-4a34-bb48-d1805c4c2b46", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "41fbaba5-530d-45c4-8ac2-003cdc444c4b"}}}]}, {"uuid": "94e1ce9a-0ea6-41c7-8acd-3c47597808c8", "name": "load_p1rlv17155_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3c6c52e-cf93-467a-a303-94b96b33a3da"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c00fb412-46d2-4e3b-b892-4c29ed9a96dc"}}}}, {"uuid": "bcd3781d-68d3-49c8-98f2-5d2dfd72d02c", "name": "c24d5d86-507c-4da1-a740-cbfa6e9b70d8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2219087879829873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3595087789107823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "367d3fb3-38e1-46a9-afe8-6002ec634b34", "name": "096662e5-09d2-4d3f-83b8-7e5c0313d32b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bcd3781d-68d3-49c8-98f2-5d2dfd72d02c"}}}]}, {"uuid": "ea2204e5-c733-4c5d-9f57-f1ae7993930e", "name": "load_p1rlv17155_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3c6c52e-cf93-467a-a303-94b96b33a3da"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "367d3fb3-38e1-46a9-afe8-6002ec634b34"}}}}, {"uuid": "5ca29a6b-8871-4316-9614-9cdc26b525c3", "name": "b34ee401-7b3b-4bd1-aecd-b49dc4a423cd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.942829069048031, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.025560880160820944, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "28234f8d-0f72-4591-a0e5-92555cccad67", "name": "26114456-b716-42bd-b5cd-0cb881ca3c1e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5ca29a6b-8871-4316-9614-9cdc26b525c3"}}}]}, {"uuid": "3788a4d6-fb67-408b-a39a-382a54c99337", "name": "load_p1rlv17164_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "041caa30-2985-44ca-8013-e11a9bda7dff"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "28234f8d-0f72-4591-a0e5-92555cccad67"}}}}, {"uuid": "d1180f7a-4072-4682-9e72-f7710c39e782", "name": "1c5d76ca-3c9e-4297-a20f-bd64dbf176a2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.942829069048031, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.025560880160820944, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "62763e78-f998-4c71-9591-66a454e2912d", "name": "3d73307b-f167-4794-a374-6943ca16307f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d1180f7a-4072-4682-9e72-f7710c39e782"}}}]}, {"uuid": "607dd42d-074f-451c-abe2-2be23e589cec", "name": "load_p1rlv17164_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "041caa30-2985-44ca-8013-e11a9bda7dff"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "62763e78-f998-4c71-9591-66a454e2912d"}}}}, {"uuid": "21a8d94a-5f88-43e9-86ad-5de85cc4c1bc", "name": "d6f25302-9bf5-4b6b-8109-772358bb7981_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.232057012168481, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2513317849586886, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d8ce9ad7-c027-48cb-8677-3e76b8508613", "name": "fc57ffc1-a1a5-4772-ab6c-285ce5f0b9be", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "21a8d94a-5f88-43e9-86ad-5de85cc4c1bc"}}}]}, {"uuid": "921af739-3a49-488e-b908-a755178667b5", "name": "load_p1rlv17167_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b4e44ab-e644-4e48-b1b2-82dc15d38d17"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d8ce9ad7-c027-48cb-8677-3e76b8508613"}}}}, {"uuid": "c95623eb-7e70-4230-89ec-95912a3b104e", "name": "870b8ada-fd08-4206-9fc5-01346c9ff362_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.232057012168481, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2513317849586886, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1ce786d2-8a25-4b49-a086-d96fa76a8d08", "name": "d75ae0f2-7d95-4690-b229-56fce3ab59ee", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c95623eb-7e70-4230-89ec-95912a3b104e"}}}]}, {"uuid": "b4f5139d-e8a9-4b09-81cc-226782639deb", "name": "load_p1rlv17167_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b4e44ab-e644-4e48-b1b2-82dc15d38d17"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1ce786d2-8a25-4b49-a086-d96fa76a8d08"}}}}, {"uuid": "7446423d-82b3-4d10-bcf9-723674add925", "name": "d3372449-16d8-484a-a833-f29fb227400d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9560799536695528, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.499516661128582, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6819cfd1-4ede-49bb-80b3-81faba8c4337", "name": "26394e59-96de-4fcd-bdf3-b8c99b381804", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7446423d-82b3-4d10-bcf9-723674add925"}}}]}, {"uuid": "a26b6799-9da9-46b0-974d-186fa2a110ef", "name": "load_p1rlv17199_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5768eaca-abe3-4347-af78-02b50ec6f2a9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6819cfd1-4ede-49bb-80b3-81faba8c4337"}}}}, {"uuid": "aec4bb52-4e0e-4666-b311-aff796a6e741", "name": "9fd2156c-d0a8-4aeb-a216-5711fc5b8345_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9560799536695528, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.499516661128582, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6bbfcac3-e8d6-49b5-b0ed-56f508d367d2", "name": "0504995a-08d3-4acf-a5ec-f035fb0edd55", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aec4bb52-4e0e-4666-b311-aff796a6e741"}}}]}, {"uuid": "f16ea12a-d96f-4c89-aae1-a9e2f73b498e", "name": "load_p1rlv17199_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5768eaca-abe3-4347-af78-02b50ec6f2a9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6bbfcac3-e8d6-49b5-b0ed-56f508d367d2"}}}}, {"uuid": "9501db4f-4d34-46ab-b337-a9b58a0ecc04", "name": "c7920de9-9700-44da-88a2-baee1b71a3fa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4651344294517608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7736313908316925, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3e397dca-c5aa-41b9-a651-a5594d57ce82", "name": "b3217784-6b6f-4cbb-ae04-0586946430b3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9501db4f-4d34-46ab-b337-a9b58a0ecc04"}}}]}, {"uuid": "486b1fa9-c97d-4d8f-8dd5-a12f4ed1f6a4", "name": "load_p1rlv17376_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c9970ae-e914-407d-8222-12c08638a854"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3e397dca-c5aa-41b9-a651-a5594d57ce82"}}}}, {"uuid": "d1c9d7de-ec26-4339-b074-a8feed5b6bd3", "name": "b9ef11a0-e24d-411d-9d2d-b1d7f910cbf7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4651344294517608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7736313908316925, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3f324903-fa8c-4c76-a937-15d2f343d5e4", "name": "365eec18-9d98-4ef6-a549-3c01f3c032ad", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d1c9d7de-ec26-4339-b074-a8feed5b6bd3"}}}]}, {"uuid": "e074293a-eec0-4036-a797-8b60e105c83f", "name": "load_p1rlv17376_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c9970ae-e914-407d-8222-12c08638a854"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3f324903-fa8c-4c76-a937-15d2f343d5e4"}}}}, {"uuid": "ead23219-08fe-44ab-820a-d0d14103563b", "name": "ba31d245-a5df-4e40-bd84-2537388de1de_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f20bbd88-d644-4460-b91b-f7d7a0dd9c33", "name": "e7afd31e-cc94-4190-bd64-93c2978c75e8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ead23219-08fe-44ab-820a-d0d14103563b"}}}]}, {"uuid": "c7830443-55ae-4071-84cd-61cb658dfa1d", "name": "load_p1rlv17402_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc7fa312-1baf-4f23-925f-a281071183a6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f20bbd88-d644-4460-b91b-f7d7a0dd9c33"}}}}, {"uuid": "c032abac-cd1f-4a1e-bbd5-d4802c4799f8", "name": "7aee58e6-4854-4da3-b1b6-cd96d079e46f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d9b0b461-3686-46ed-a372-44fe942df55a", "name": "08b8a5f8-54ac-4bef-9a93-f060a37836e7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c032abac-cd1f-4a1e-bbd5-d4802c4799f8"}}}]}, {"uuid": "c4c2d28d-64de-4aef-9b56-71b581140ea8", "name": "load_p1rlv17402_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc7fa312-1baf-4f23-925f-a281071183a6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d9b0b461-3686-46ed-a372-44fe942df55a"}}}}, {"uuid": "c6d70775-0474-4758-9e2b-53a281b01f2b", "name": "951110b2-1b20-46ea-97ea-669c68971c74_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cece30de-5748-49d0-95c9-04aae051c96b", "name": "934dfe2f-a3da-4353-ab7d-ff5cf4bd4aca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c6d70775-0474-4758-9e2b-53a281b01f2b"}}}]}, {"uuid": "4de72967-d0e0-4245-a2c9-90ed95c634db", "name": "load_p1rlv17413_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f147f7e5-33e8-430b-9822-715e772debb3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cece30de-5748-49d0-95c9-04aae051c96b"}}}}, {"uuid": "410be76a-d3e6-4fe5-8234-da21b56ab803", "name": "86f67b91-abe0-4707-b5b7-1fc268250b03_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a1f185f9-ed32-4e4d-8ab5-4cb30f46e1fa", "name": "be5f5a1e-d7c2-4cc0-b2ec-ebb2f4d99001", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "410be76a-d3e6-4fe5-8234-da21b56ab803"}}}]}, {"uuid": "c17dc359-c1e8-4ac0-b8b5-6f4911806a06", "name": "load_p1rlv17413_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f147f7e5-33e8-430b-9822-715e772debb3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a1f185f9-ed32-4e4d-8ab5-4cb30f46e1fa"}}}}, {"uuid": "2b1560aa-044b-4355-a313-8393ed56e206", "name": "7091f011-29cf-4970-a077-57d16406022c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.892763602300674, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6648734705927571, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4bc73f95-dad0-426c-9936-a29efa07e8e8", "name": "54d54f42-88ad-4e97-8ab7-0abf5a820925", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2b1560aa-044b-4355-a313-8393ed56e206"}}}]}, {"uuid": "bdf7f58c-d310-4d81-a73e-f4b0b1a4ce42", "name": "load_p1rlv18362_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a28b095-45f5-43ec-983b-c1de596d4cb5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4bc73f95-dad0-426c-9936-a29efa07e8e8"}}}}, {"uuid": "257a4574-d5ef-4c96-9b9f-d77e051fafe0", "name": "91b731da-63f3-4bc2-b6e9-af3b83093c8d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.892763602300674, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6648734705927571, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d8380065-441a-43ce-be4c-f8346bb2f521", "name": "2874337f-dfcb-4793-be27-1510b75a005f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "257a4574-d5ef-4c96-9b9f-d77e051fafe0"}}}]}, {"uuid": "d490ecf2-bbea-47c7-acb6-20d2732d4e2e", "name": "load_p1rlv18362_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a28b095-45f5-43ec-983b-c1de596d4cb5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d8380065-441a-43ce-be4c-f8346bb2f521"}}}}, {"uuid": "75ddb8f7-60f7-490b-bf33-5873e706c7bf", "name": "87c379cb-60d1-4d1c-a9cd-99664fa99d1c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6733980323267108, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22626974414284334, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "584dc0fb-4cac-4f30-9134-437168f50f38", "name": "b498951a-0c47-4046-ad51-574662d33fe5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "75ddb8f7-60f7-490b-bf33-5873e706c7bf"}}}]}, {"uuid": "16da4765-2a94-42b2-8fa3-ee4d896e71d7", "name": "load_p1rlv18364_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d1c3d0a-9def-4516-8429-386f1d70f506"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "584dc0fb-4cac-4f30-9134-437168f50f38"}}}}, {"uuid": "92e69644-de04-43d7-b2e1-0e3bd74982eb", "name": "266a88e0-df41-41ca-bfb6-60e12a5941f7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6733980323267108, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22626974414284334, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e9864b39-af63-4922-a8d4-02e847767bcc", "name": "a91ad431-0ff6-4239-b74c-a5d9e3850a5c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "92e69644-de04-43d7-b2e1-0e3bd74982eb"}}}]}, {"uuid": "da244663-5b6a-4fd8-a1f5-ac4badf33a37", "name": "load_p1rlv18364_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d1c3d0a-9def-4516-8429-386f1d70f506"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e9864b39-af63-4922-a8d4-02e847767bcc"}}}}, {"uuid": "a9ddfd1d-3312-40ce-bb2e-0ad14e5534c0", "name": "1952fc3c-5bb1-4426-aedd-3b281fbbcce4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5880239691905954, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.38099900657746644, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4b8ad38a-67e8-44ef-85a8-e7448d462d0f", "name": "66287ea0-a48c-4197-8596-01b7383329a5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a9ddfd1d-3312-40ce-bb2e-0ad14e5534c0"}}}]}, {"uuid": "b9c897cb-86a2-49e9-9eb4-373574153ce3", "name": "load_p1rlv18367_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "408c825d-17ac-4aea-9fc7-fff420657fc7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4b8ad38a-67e8-44ef-85a8-e7448d462d0f"}}}}, {"uuid": "743c8186-d479-45e9-b3bc-a35e639913a6", "name": "5dd5f3e7-b82b-4663-aa29-5f66bf7ec617_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5880239691905954, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.38099900657746644, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "accd5657-d180-46cc-b3f6-078c5d6c4023", "name": "ef824912-fe95-47a6-a947-dc3cd4ae0fe6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "743c8186-d479-45e9-b3bc-a35e639913a6"}}}]}, {"uuid": "2bb645d5-61aa-411d-a6ca-d3858ae387f3", "name": "load_p1rlv18367_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "408c825d-17ac-4aea-9fc7-fff420657fc7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "accd5657-d180-46cc-b3f6-078c5d6c4023"}}}}, {"uuid": "7b1b9654-8f6f-41f8-9949-7c667f121221", "name": "ae93fb7d-8b86-4bc8-8c76-23340af3316e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.287089484997603, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1789824543876289, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "40b0ac72-0e92-4d11-8da5-eac2a4d51459", "name": "a32daa16-e1f3-4307-b131-b623a894e02a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b1b9654-8f6f-41f8-9949-7c667f121221"}}}]}, {"uuid": "188c068c-f0d5-42db-b95f-b14c18ac3ead", "name": "load_p1rlv18370_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905e171c-13d7-4f8d-b88a-7501b2327d81"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "40b0ac72-0e92-4d11-8da5-eac2a4d51459"}}}}, {"uuid": "68317224-66ee-48bc-b78a-da4bb713889f", "name": "e2e5bbaa-022b-4234-992f-0c2ac3cf90a1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.287089484997603, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1789824543876289, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "41fea339-814b-42d1-8c26-64a3fa35ebbe", "name": "18efa5ce-5d1b-485f-9ecc-c872b07928f1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "68317224-66ee-48bc-b78a-da4bb713889f"}}}]}, {"uuid": "9ae409db-c6ba-45ca-9a8a-331455db2e0e", "name": "load_p1rlv18370_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905e171c-13d7-4f8d-b88a-7501b2327d81"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "41fea339-814b-42d1-8c26-64a3fa35ebbe"}}}}, {"uuid": "793805f3-a494-4fa1-a522-74e0ac925749", "name": "dfb5f81d-e24b-45c7-8605-ddb09f7d9eb3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2520868864654517, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.447133871274774, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d5aa70af-2ee7-4b7d-b94f-3ea222b385c2", "name": "125e24fe-6596-4d6d-94db-5dbf4bc5e421", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "793805f3-a494-4fa1-a522-74e0ac925749"}}}]}, {"uuid": "0f43e824-7939-4679-98c8-608f518dd550", "name": "load_p1rlv18371_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58792e8c-3ad9-45bb-ac47-01983cca2a2b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d5aa70af-2ee7-4b7d-b94f-3ea222b385c2"}}}}, {"uuid": "69f19827-944b-4a54-a28e-0dfe9c47b0fc", "name": "390f6dbf-4017-4c8e-bceb-b4bfeb8f2003_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2520868864654517, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.447133871274774, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e70868cc-51f0-42a5-819e-83d4b3dbf361", "name": "931fc67d-b740-4547-9b8b-b33ffdbde5cb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "69f19827-944b-4a54-a28e-0dfe9c47b0fc"}}}]}, {"uuid": "67f1c6b3-83b2-48f1-9099-9b28b64418ad", "name": "load_p1rlv18371_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58792e8c-3ad9-45bb-ac47-01983cca2a2b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e70868cc-51f0-42a5-819e-83d4b3dbf361"}}}}, {"uuid": "b686fa6e-2461-4808-9066-25867f45ba9d", "name": "420e1a0a-ffcb-4581-8b92-d552392c4fee_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8791002615066037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24190904367644575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b9fcde9a-cbbd-4ec9-92f8-ff41efd0cf35", "name": "7c92f79e-4b96-4736-b8a9-6742d7ac1ddb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b686fa6e-2461-4808-9066-25867f45ba9d"}}}]}, {"uuid": "b7724836-8957-44b6-a1ee-1e13527201ca", "name": "load_p1rlv22745_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a86348e4-7573-4903-b223-90155579923e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b9fcde9a-cbbd-4ec9-92f8-ff41efd0cf35"}}}}, {"uuid": "53db9d3b-3c21-40c5-80a9-ef617736c9a8", "name": "5ff251b3-da3d-4586-825b-ac39058ba513_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8791002615066037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24190904367644575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5a8333e2-17ee-4e51-a880-051e78240562", "name": "4aaed0fb-53e6-4c5b-9cab-4e1899e05ed4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "53db9d3b-3c21-40c5-80a9-ef617736c9a8"}}}]}, {"uuid": "85381bbb-b76b-4491-8426-3f1f546557da", "name": "load_p1rlv22745_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a86348e4-7573-4903-b223-90155579923e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5a8333e2-17ee-4e51-a880-051e78240562"}}}}, {"uuid": "2616a540-3729-4d1c-9e19-3e6dd7591c99", "name": "0d546f4b-fb69-4955-892c-71bff61644ad_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4163439957648214, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5697938312046736, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "573e0cb7-9d98-4b90-8399-be6d8152d6aa", "name": "8080e54c-51ef-46b6-b0ec-6207aec4ee3e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2616a540-3729-4d1c-9e19-3e6dd7591c99"}}}]}, {"uuid": "e52b1a47-a419-442d-ad0a-75dd5602f688", "name": "load_p1rlv22758_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db05b7f0-d2a8-4876-876e-ef0e9b469580"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "573e0cb7-9d98-4b90-8399-be6d8152d6aa"}}}}, {"uuid": "6e457b9f-df86-4742-8b47-d0463266fc5c", "name": "f96e1a4f-9a54-4b4c-b072-9ccb0d534841_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4163439957648214, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5697938312046736, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6733e95a-a926-463a-b097-3eadebfffe1b", "name": "f77f6636-5ffb-4446-a8c7-6d920b16449a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6e457b9f-df86-4742-8b47-d0463266fc5c"}}}]}, {"uuid": "462e1f9c-3a5f-4f5b-a281-0d93e7ab513d", "name": "load_p1rlv22758_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db05b7f0-d2a8-4876-876e-ef0e9b469580"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6733e95a-a926-463a-b097-3eadebfffe1b"}}}}, {"uuid": "e4ea7fd7-7dd6-4aa3-b984-f4806c69c9cd", "name": "", "resistance": 0.33831264, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 3, "connection_type": "DELTA", "tap_positions": [1.0, 1.0, 1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 39.838337182448036, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 30000.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "9a9d218f-3818-4abe-9c9f-7fee34acb7cc", "name": "", "resistance": 0.33831264, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 3, "connection_type": "STAR", "tap_positions": [1.03125, 1.03125, 1.03125], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.199769053117783, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 30000.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "0ff22131-b16e-4e2e-808a-862b62584bf5", "name": "5ea8fd3b-2d5b-4c48-84db-0b2934c03576", "pct_no_load_loss": 0.0, "pct_full_load_loss": 0.67662528, "coupling_sequences": [[1, 2]], "winding_reactances": [7.40307669516232], "is_center_tapped": false, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "e4ea7fd7-7dd6-4aa3-b984-f4806c69c9cd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "9a9d218f-3818-4abe-9c9f-7fee34acb7cc"}}}]}, {"uuid": "43f6bef8-6670-432e-967e-238f41116cd3", "name": "", "resistance": 0.266272, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.2, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 25.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "d7f56744-2b80-450f-96df-d394c22746ae", "name": "", "resistance": 0.532544, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 0.12, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 25.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "fc204377-0430-4e39-92d8-12637b9626bd", "name": "c90ce3f4-34f4-43b1-9398-685a67188e1f", "pct_no_load_loss": 0.472, "pct_full_load_loss": 0.798816, "coupling_sequences": [[1, 2], [1, 3], [2, 3]], "winding_reactances": [2.4, 1.6, 2.4], "is_center_tapped": true, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "43f6bef8-6670-432e-967e-238f41116cd3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "d7f56744-2b80-450f-96df-d394c22746ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "d7f56744-2b80-450f-96df-d394c22746ae"}}}]}, {"uuid": "409027f9-8175-46a5-9446-3197e251f48e", "name": "", "resistance": 0.41605, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.2, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 10.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "9482a710-e97e-42d4-9afe-b8a7af1d4dd2", "name": "", "resistance": 0.832101, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 0.12, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 10.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39", "name": "4e1e5ead-0aba-4efa-8a66-7f0837cdfdb3", "pct_no_load_loss": 0.68, "pct_full_load_loss": 1.248151, "coupling_sequences": [[1, 2], [1, 3], [2, 3]], "winding_reactances": [1.08, 0.72, 1.08], "is_center_tapped": true, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "409027f9-8175-46a5-9446-3197e251f48e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "9482a710-e97e-42d4-9afe-b8a7af1d4dd2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "9482a710-e97e-42d4-9afe-b8a7af1d4dd2"}}}]}, {"uuid": "af41736a-6c75-4cfe-a051-04f517ad6634", "name": "", "resistance": 0.16642, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.2, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 75.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "a59da237-5e2b-4026-aa20-285c4f5ac91a", "name": "", "resistance": 0.33284, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 0.12, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 75.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "e2f53d7d-7442-4b42-8617-11656e408189", "name": "7069cfb8-3af7-4776-b0a7-3ee93d0a6d00", "pct_no_load_loss": 0.38, "pct_full_load_loss": 0.49926, "coupling_sequences": [[1, 2], [1, 3], [2, 3]], "winding_reactances": [2.4, 1.6, 2.4], "is_center_tapped": true, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "af41736a-6c75-4cfe-a051-04f517ad6634"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "a59da237-5e2b-4026-aa20-285c4f5ac91a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "a59da237-5e2b-4026-aa20-285c4f5ac91a"}}}]}, {"uuid": "e45fd6cc-f0ba-4fec-a6cc-8de2e6071dd5", "name": "", "resistance": 0.87204, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 3, "connection_type": "STAR", "tap_positions": [1.0, 1.0, 1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.199769053117783, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 75.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "cedafdc8-4789-49a5-b801-1112786f4229", "name": "", "resistance": 0.87204, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 3, "connection_type": "STAR", "tap_positions": [1.0, 1.0, 1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 0.27713625866050806, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 75.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39", "name": "25e347d1-54f4-4401-a111-bc5b034415d8", "pct_no_load_loss": 0.6, "pct_full_load_loss": 1.74408, "coupling_sequences": [[1, 2]], "winding_reactances": [3.24], "is_center_tapped": false, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "e45fd6cc-f0ba-4fec-a6cc-8de2e6071dd5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "cedafdc8-4789-49a5-b801-1112786f4229"}}}]}, {"uuid": "5f0d2c9e-13b8-4f29-8af9-6188720eedac", "name": "", "resistance": 0.199704, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.2, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 50.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "43ae60da-acbb-41be-b1e9-850c4e760ec4", "name": "", "resistance": 0.399408, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 0.12, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 50.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208", "name": "dcf66ff7-2c37-4071-944c-a1a7c55efdd0", "pct_no_load_loss": 0.37, "pct_full_load_loss": 0.599112, "coupling_sequences": [[1, 2], [1, 3], [2, 3]], "winding_reactances": [2.4, 1.6, 2.4], "is_center_tapped": true, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "5f0d2c9e-13b8-4f29-8af9-6188720eedac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "43ae60da-acbb-41be-b1e9-850c4e760ec4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "43ae60da-acbb-41be-b1e9-850c4e760ec4"}}}]}, {"uuid": "a0c12460-ccac-452f-9740-c1574cf5bb1f", "name": "", "resistance": 0.266272, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.2, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 50.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "f6e9a1ac-c88b-4fe2-a154-24f5f7642ecf", "name": "", "resistance": 0.532544, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 0.12, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 50.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "fac52057-f5c2-4934-9fe6-6517159b5db2", "name": "c008ed76-f669-42ff-b5cd-d16b05f9d6a9", "pct_no_load_loss": 0.472, "pct_full_load_loss": 0.798816, "coupling_sequences": [[1, 2], [1, 3], [2, 3]], "winding_reactances": [2.4, 1.6, 2.4], "is_center_tapped": true, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "a0c12460-ccac-452f-9740-c1574cf5bb1f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "f6e9a1ac-c88b-4fe2-a154-24f5f7642ecf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "f6e9a1ac-c88b-4fe2-a154-24f5f7642ecf"}}}]}, {"uuid": "777a7223-aa6f-4f59-8319-64339d066aab", "name": "93ddfc44-8481-4bdf-ab60-e9ff52bb462f", "pct_no_load_loss": 0.37, "pct_full_load_loss": 0.798816, "coupling_sequences": [[1, 2], [1, 3], [2, 3]], "winding_reactances": [2.4, 1.6, 2.4], "is_center_tapped": true, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "a0c12460-ccac-452f-9740-c1574cf5bb1f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "f6e9a1ac-c88b-4fe2-a154-24f5f7642ecf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "f6e9a1ac-c88b-4fe2-a154-24f5f7642ecf"}}}]}, {"uuid": "bd55901d-7c9b-4820-ae8e-57c9ca06328f", "name": "", "resistance": 0.266272, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.2, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 75.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "cd8890eb-9546-4f24-acce-6fcf2ee84c86", "name": "", "resistance": 0.532544, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 0.12, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 75.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "5b183af9-59bd-450e-bea6-e545db99accd", "name": "9d1848f6-5882-41b9-b2a8-c82d69262c5d", "pct_no_load_loss": 0.37, "pct_full_load_loss": 0.798816, "coupling_sequences": [[1, 2], [1, 3], [2, 3]], "winding_reactances": [2.4, 1.6, 2.4], "is_center_tapped": true, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "bd55901d-7c9b-4820-ae8e-57c9ca06328f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "cd8890eb-9546-4f24-acce-6fcf2ee84c86"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "cd8890eb-9546-4f24-acce-6fcf2ee84c86"}}}]}, {"uuid": "d7f8bb16-2fa2-44b9-9ef9-402d0cdb4de0", "name": "", "resistance": 0.41605, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.2, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 25.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "13913f15-8cf3-4455-991c-233f79168c29", "name": "", "resistance": 0.832101, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 0.12, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 25.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "7ecefea9-516a-4cb1-8c06-cac3a09bcc5e", "name": "c3e09961-f803-4e36-b0bb-ca80f2402057", "pct_no_load_loss": 0.68, "pct_full_load_loss": 1.248151, "coupling_sequences": [[1, 2], [1, 3], [2, 3]], "winding_reactances": [1.08, 0.72, 1.08], "is_center_tapped": true, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "d7f8bb16-2fa2-44b9-9ef9-402d0cdb4de0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "13913f15-8cf3-4455-991c-233f79168c29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "13913f15-8cf3-4455-991c-233f79168c29"}}}]}, {"uuid": "cb14ae0e-2eb0-4352-9990-bab8587ecbc3", "name": "sb10_p1rhs7_1247_trans_301", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16bb904e-b153-4b0a-97f5-53ad7c6606d8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "001adbd4-6616-4dce-83d2-025e896ada51"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0ff22131-b16e-4e2e-808a-862b62584bf5"}}}}, {"uuid": "0f8211a9-3a1c-4289-91ed-70595408cdb6", "name": "tr(r:p1rdt4964-p1rdt4964lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7f13598-e628-457c-9ba6-d9a0123e882c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3541a1a-9680-4baf-9b87-a1322cb1a16a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3541a1a-9680-4baf-9b87-a1322cb1a16a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "4459a649-5f2a-49a5-ad44-234e0a27c101", "name": "tr(r:p1rdt4980-p1rdt4980lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ddb0629-4947-47ca-83f9-9b7c073db235"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab731358-e17f-4c48-b6f8-c7bb4c7701de"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab731358-e17f-4c48-b6f8-c7bb4c7701de"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "a14eb44e-8274-4874-9188-51fccadf71e2", "name": "tr(r:p1rdt5017-p1rdt5017lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c09f718-9379-4281-86f6-55c46e46aec6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0375d197-ccd2-4ed8-9439-857b700cefb8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0375d197-ccd2-4ed8-9439-857b700cefb8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f59e21f9-fe45-41c0-9dfb-d93eeb5c5a9b", "name": "tr(r:p1rdt5126-p1rdt5126lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0dafde2-c08e-4624-9212-e0fea9e47c2c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e33e473-8d5b-4704-bdab-56032991f94e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e33e473-8d5b-4704-bdab-56032991f94e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "a224a322-e724-45d6-b4de-232506f9f06e", "name": "tr(r:p1rdt5140-p1rdt5140lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b0fd055-d0ac-4678-a8e5-679e12741736"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f114a56-98d7-4fe8-b0b1-b8c4bc791cf9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f114a56-98d7-4fe8-b0b1-b8c4bc791cf9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "8d206fac-69f4-4fad-9199-94c1209314a0", "name": "tr(r:p1rdt5142-p1rdt5142lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d579047b-82f6-49bf-bd7b-28c818d44bb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e071635-4071-470d-be09-4484cb90441a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e071635-4071-470d-be09-4484cb90441a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "316c1908-f8c8-4724-99c8-68acd6ca28e6", "name": "tr(r:p1rdt5153-p1rdt5153lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb8dae66-287a-4b8a-9cda-6ae02cb8f8a9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ec20ad2-b04f-43fc-ad8d-d41746549a57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ec20ad2-b04f-43fc-ad8d-d41746549a57"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "f6e301fe-1473-4823-8abc-5bb307b2ce1a", "name": "tr(r:p1rdt5154-p1rdt5154lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50332aed-ecfd-465a-977e-c24ed6462860"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9750085f-4afd-48ee-89f3-edbe9687b242"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "5e034209-8f4d-4112-bf2e-fc5d831d0b41", "name": "tr(r:p1rdt5155-p1rdt5155lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16712e10-4c7f-428b-917b-135ab3c2d4b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85351f49-cb19-4f71-a6ae-a21f5a48af6f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85351f49-cb19-4f71-a6ae-a21f5a48af6f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "5a444dd7-7ccc-4ad8-bdb1-e278ecb6ab5b", "name": "tr(r:p1rdt5159-p1rdt5159lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90fb2270-4759-4779-80c1-7f93d66e1c53"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba7e3a6b-f62f-432f-afe7-2ebbfc9abd59"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba7e3a6b-f62f-432f-afe7-2ebbfc9abd59"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "224f6b7f-ed33-4683-96f3-f5463456d1f4", "name": "tr(r:p1rdt5172-p1rdt5172lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ea481f8-b9c7-4067-9bfb-4f7cdc5dee15"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48efdcb9-083c-4e17-a1d2-acb1388f085e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48efdcb9-083c-4e17-a1d2-acb1388f085e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d096b871-d8cf-49e3-a9d8-bce4ee870d37", "name": "tr(r:p1rdt5179-p1rdt5179lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d22f1247-b756-4498-8cf8-fef7d1e859ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd4155b2-ca55-41d7-bd35-98a5eec8c39a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd4155b2-ca55-41d7-bd35-98a5eec8c39a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "03f5affd-877c-44f3-a574-df7d0a34d7bf", "name": "tr(r:p1rdt5180-p1rdt5180lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6316fa2-dd57-46d4-89c0-f11dd675d686"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae26acb3-c2c9-479c-9d19-c30bf00aa8c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae26acb3-c2c9-479c-9d19-c30bf00aa8c5"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "1b56638f-139e-4db8-93ee-87c32a4330ef", "name": "tr(r:p1rdt5183-p1rdt5183lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23f0bb81-3c30-45a5-89ca-2011e3881ddb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bbde2e8-42c0-486b-9759-78898d177f93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bbde2e8-42c0-486b-9759-78898d177f93"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4d397307-5f03-484b-bb97-2343016c603d", "name": "tr(r:p1rdt5184-p1rdt5184lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "431b672b-cb45-4294-b1f9-1d63f4efc8db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1656cc28-8a5b-40da-887f-25605dd336aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1656cc28-8a5b-40da-887f-25605dd336aa"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "7cee3b1b-3e70-4066-ae18-13419331a26b", "name": "tr(r:p1rdt5195-p1rdt5195lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58c6d858-d457-4fe6-a45b-b9b2b73cad8c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf05c1bb-39cc-48b3-a576-18913e0cff13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf05c1bb-39cc-48b3-a576-18913e0cff13"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "39039b81-4e2f-42c7-b890-1bf3d089058a", "name": "tr(r:p1rdt5200-p1rdt5200lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "799ab435-c0a4-4515-8125-e8ca2fb7632d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "03e7bfdb-ff8b-4142-95ef-8d848ff5d2db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "03e7bfdb-ff8b-4142-95ef-8d848ff5d2db"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "02b53edb-2e1f-4263-9d58-d6f7837fee8b", "name": "tr(r:p1rdt5201-p1rdt5201lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c289632-ba52-4b65-b6da-ac76b1477246"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8162a8c-5339-4f42-bd7a-b6dbc5ff463b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8162a8c-5339-4f42-bd7a-b6dbc5ff463b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "403188b7-0c92-46b1-b0a0-72798d290fa2", "name": "tr(r:p1rdt5202-p1rdt5202lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97e4f179-9d60-4183-8326-eb0ab98a53eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "39eaedd7-75b6-449f-8ff6-6e31f6e74504"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "39eaedd7-75b6-449f-8ff6-6e31f6e74504"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b875dd86-44ae-41fc-b621-1d50fd1369ab", "name": "tr(r:p1rdt5206-p1rdt5206lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ed081eb-6b56-43b8-9cf8-e7ffdd8222f2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "599a2995-33d5-4bcc-8cd3-585ea37577cd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "599a2995-33d5-4bcc-8cd3-585ea37577cd"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "cfd7929a-5a92-40d0-8117-68f69e67d917", "name": "tr(r:p1rdt5218-p1rdt5218lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dda7f7c-3b21-46a0-88a3-2b7f028b7772"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c650eda9-132b-4419-a055-ad68037c7772"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c650eda9-132b-4419-a055-ad68037c7772"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "e226528d-6510-43cc-9946-faedc99958f7", "name": "tr(r:p1rdt5236-p1rdt5236lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22db53ea-6d9a-4527-9b36-34a4bcd2c74f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f252d81-66ee-40a6-bce7-2891e06b39e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f252d81-66ee-40a6-bce7-2891e06b39e4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "897a5ce1-914d-454b-a71c-5980ff30cc2f", "name": "tr(r:p1rdt5342-p1rdt5342lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c8f9ea6-06fb-4fd0-8629-ceea4f32189f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e01069aa-388b-4362-9d02-a164f173dc20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e01069aa-388b-4362-9d02-a164f173dc20"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "519868f4-b58e-4fdc-b749-5324585674fa", "name": "tr(r:p1rdt5472-p1rdt5472lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a8c3f7f-b9be-4c5e-b6f0-8f2fc18935fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34a1276e-c702-4c69-b7b1-566d400da2de"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34a1276e-c702-4c69-b7b1-566d400da2de"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "3afcd18e-c615-4125-9695-1bf38cf70f51", "name": "tr(r:p1rdt5475-p1rdt5475lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b9e57e0-6dc8-4831-ac7d-36f8608b7a8d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d181674-9355-488b-8a3f-5b7c844c35a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d181674-9355-488b-8a3f-5b7c844c35a5"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "5cd3e55d-3396-480b-b9cd-00b92b563c79", "name": "tr(r:p1rdt5476-p1rdt5476lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b077dc9c-1c6f-4403-ae0c-954e7cc0c692"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0888f4c5-e037-4891-99fb-fd43934ffae0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0888f4c5-e037-4891-99fb-fd43934ffae0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "38e532e3-559a-4907-853d-7cd08b7d5493", "name": "tr(r:p1rdt5477-p1rdt5477lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7d7f462-1ab5-4fd8-baaa-7e576eead5c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fafd64c3-efe5-4684-b06f-44e4c8555aa4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fafd64c3-efe5-4684-b06f-44e4c8555aa4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "473cf7e7-cc10-4402-a7d2-42b4288be59b", "name": "tr(r:p1rdt5478-p1rdt5478lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a97491e-2c98-4584-9b74-5593f17faeda"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5107bc9c-f463-49f6-a92f-23c5730475e2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5107bc9c-f463-49f6-a92f-23c5730475e2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "f3d168ab-98b0-4f71-a258-4db4b923422f", "name": "tr(r:p1rdt5480-p1rdt5480lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2568f11c-8a37-4a55-8bce-9f0d56ac386a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44ac9e38-8ae3-4102-822b-1c638a6c878a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44ac9e38-8ae3-4102-822b-1c638a6c878a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6ab40212-5945-4e0d-be6c-547813180165", "name": "tr(r:p1rdt5481-p1rdt5481lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d29d8b74-a24d-4474-9752-c1ffa1aa7f7c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f213ee9e-6ae7-4e82-9f25-6fc456f45576"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f213ee9e-6ae7-4e82-9f25-6fc456f45576"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "804a9ecc-be85-4926-84d2-1879c6008a6e", "name": "tr(r:p1rdt5483-p1rdt5483lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f903015c-95a7-4d6e-b2a5-e9705c050c6e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a73d544-9f33-49d9-b648-c806addf3c06"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a73d544-9f33-49d9-b648-c806addf3c06"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "e47a7160-32cb-47d7-a35d-f30bb1d87bc9", "name": "tr(r:p1rdt5485-p1rdt5485lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cfb3a23-3a93-4d89-8b70-e4730ebbce1a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40eaefce-482f-4a89-bec1-2c11bac2bfb7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40eaefce-482f-4a89-bec1-2c11bac2bfb7"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "3c03d8f3-d40a-4b30-8f4b-39116f72993e", "name": "tr(r:p1rdt5650-p1rdt5650lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8f1c67e-9e29-45a3-a2a3-c2f3493a6898"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28a6e44b-c6c7-4556-b4d8-d55359391c66"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28a6e44b-c6c7-4556-b4d8-d55359391c66"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "442a6df8-1877-4263-a9de-b6a18ae053ad", "name": "tr(r:p1rdt5653-p1rdt5653lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "769c14db-ac3f-438d-9f7d-c7eb2d3074b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38d1de19-1f51-4875-acc2-a75e3d1a290e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38d1de19-1f51-4875-acc2-a75e3d1a290e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b88a89f2-d5e8-45bd-939b-2476952d2902", "name": "tr(r:p1rdt5656-p1rdt5656lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f417a58d-5a47-4310-bac6-e8bb95fffc19"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "87e8c57e-67ff-439c-b28b-0fbdbfd62ea6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "87e8c57e-67ff-439c-b28b-0fbdbfd62ea6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "a62dc441-3832-46a8-9fe3-5ad01441938c", "name": "tr(r:p1rdt5658-p1rdt5658lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81d6db26-881f-4cae-9514-df4c1e71c76e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f718935b-704d-4374-9172-856511e1eddd"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "1bc7dee2-3a73-4bf6-b9e5-5a51eb44b4ff", "name": "tr(r:p1rdt5662-p1rdt5662lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17e89212-bc51-4fc2-83d1-4c74a285be23"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea73a91a-b052-486e-810b-1a5ad281e07b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea73a91a-b052-486e-810b-1a5ad281e07b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "48c1ed45-922f-4c58-b9d0-26d6c91138f3", "name": "tr(r:p1rdt5663-p1rdt5663lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7356d982-36fd-46cb-9300-8889502e8dc8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16a67a88-5d11-4eca-85fe-38c948ad362c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16a67a88-5d11-4eca-85fe-38c948ad362c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "85ffc857-6af0-4a86-bcdd-734da36e5718", "name": "tr(r:p1rdt5728-p1rdt5728lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b55c58cf-153e-4aa3-b099-8a1db05a6ae5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6d456893-4d89-455a-b1a5-4863aad6293a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6d456893-4d89-455a-b1a5-4863aad6293a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4f92fde2-27d2-48b7-aab1-425ccf2fedee", "name": "tr(r:p1rdt5729-p1rdt5729lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "77d2122b-cbb7-4844-bbb2-55e939431e50"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95f81d7a-a6af-4843-bfa1-002abc7ff870"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95f81d7a-a6af-4843-bfa1-002abc7ff870"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "0783f792-d931-4d06-a008-d6dff90de5cb", "name": "tr(r:p1rdt5730-p1rdt5730lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5897bb2-1f72-4aeb-9090-74e2411b5786"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2dd206bc-965d-46c9-8fdb-8c158c7bba05"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2dd206bc-965d-46c9-8fdb-8c158c7bba05"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "5a2f8d06-f5c2-4ff9-befb-b1580884d748", "name": "tr(r:p1rdt5731-p1rdt5731lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95cd61cf-f1cb-4af2-9d3b-e42978642003"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e414162-eda7-4cf2-9116-fc24af9461bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e414162-eda7-4cf2-9116-fc24af9461bf"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6d3ddf78-01dd-4545-865b-513b8a016d38", "name": "tr(r:p1rdt5840-p1rdt5840lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35722d90-049e-4c67-9654-acce0572e6c2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9974869d-7d87-4a27-9606-076cd7799953"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9974869d-7d87-4a27-9606-076cd7799953"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "7a69c32d-25c9-4ba6-9763-bc883b42aec6", "name": "tr(r:p1rdt5923-p1rdt5923lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fec8a81-a151-4d8f-adc7-6d6d87d7759f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "751d2f2e-bb6f-4ca6-9e86-0e2b5ff3f92a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "751d2f2e-bb6f-4ca6-9e86-0e2b5ff3f92a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "7c2647c5-6bca-4086-b50e-8dc4d3699dd7", "name": "tr(r:p1rdt6038-p1rdt6038lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8898950-d712-40dc-99b5-33882b96b225"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d654945d-b71d-4943-86a2-5830fca200c9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d654945d-b71d-4943-86a2-5830fca200c9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4f7e809a-a82d-4bf0-ac51-229280ce4fd9", "name": "tr(r:p1rdt6043-p1rdt6043lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "87e05b2f-c346-452c-9c72-a6db090c3124"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ae7bbf-f53e-4ae2-8145-bf56ce935094"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ae7bbf-f53e-4ae2-8145-bf56ce935094"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fac52057-f5c2-4934-9fe6-6517159b5db2"}}}}, {"uuid": "df4304d6-f35e-4caa-b702-71b3da08c77f", "name": "tr(r:p1rdt6045-p1rdt6045lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0396342e-2dc8-4a01-9da9-513953f9b5fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70bad714-71c1-4341-ac40-76312417dd03"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "1fda4c61-98bf-494b-a4be-a77eef41867b", "name": "tr(r:p1rdt6046-p1rdt6046lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67bc3ce6-e23d-4899-b0e8-9783225338ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2e2d1a7-039c-4b29-a061-b814ac675e3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2e2d1a7-039c-4b29-a061-b814ac675e3b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "123088f7-943a-4feb-845b-85900240a87f", "name": "tr(r:p1rdt6047-p1rdt6047lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34a9d21e-bcf7-4266-9834-60a72878ddd4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21e75ccd-7e21-4f0d-890c-81aa6b33b109"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21e75ccd-7e21-4f0d-890c-81aa6b33b109"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "62ef838d-937e-4760-aabd-f8478054f480", "name": "tr(r:p1rdt6052-p1rdt6052lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c10f182d-aa76-4633-9a84-f41e20b97da1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d830a1b-6971-4f4d-99bd-945e0785b5aa"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "e1db1007-4c7e-413b-9d88-ee84e9bd8284", "name": "tr(r:p1rdt6208-p1rdt6208lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdfc617f-fbfb-4e9a-862e-cd5a296748cb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01be483b-09f4-450e-a39d-78692c40ee8b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01be483b-09f4-450e-a39d-78692c40ee8b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b0843684-b05b-4654-bc0e-d00707551a2b", "name": "tr(r:p1rdt6221-p1rdt6221lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0809ec5e-d36f-4bea-91b3-962ad6c29606"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73f78740-2ec5-4ad8-b7fb-40f4a72b730e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73f78740-2ec5-4ad8-b7fb-40f4a72b730e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "cf49bac9-27de-4e9d-98a7-f4a7be482fcf", "name": "tr(r:p1rdt6226-p1rdt6226lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d81fc6d7-3400-41d4-91d7-b350d7def98d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3154eee7-a1ba-4b9d-9e91-bab55529d358"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3154eee7-a1ba-4b9d-9e91-bab55529d358"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f910561f-ff5c-4353-ad1e-f22354339f22", "name": "tr(r:p1rdt6268-p1rdt6268lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2f8b91d-339f-4151-90df-b0cad5c2f05a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72ce0706-6b32-4b4b-9bf3-fd1f5a6af5ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72ce0706-6b32-4b4b-9bf3-fd1f5a6af5ca"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "d630f404-730d-43bf-adf8-c8d3a01cf56a", "name": "tr(r:p1rdt6269-p1rdt6269lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5ef97a6-6c60-46eb-acce-6469b273658a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79c91fa8-15ad-4e8d-96bd-2cad395dd280"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79c91fa8-15ad-4e8d-96bd-2cad395dd280"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "194e335f-7fd7-49b3-8533-23c4e6813e0e", "name": "tr(r:p1rdt6270-p1rdt6270lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cf36152-b3af-49f7-b693-5d465db1f283"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5adb2083-3d46-48a7-8996-37c0781b0215"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5adb2083-3d46-48a7-8996-37c0781b0215"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "cbbbeabe-626d-49b9-8577-1ddaec69fd68", "name": "tr(r:p1rdt6271-p1rdt6271lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a75c5e2-2277-42b4-87d4-6eadff5c06f1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1335e64c-9f37-4e73-a37f-8f76737cabff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1335e64c-9f37-4e73-a37f-8f76737cabff"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "74954554-5d2e-4b28-bb8d-40c669296046", "name": "tr(r:p1rdt6272-p1rdt6272lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "034bda10-d48e-449c-9255-247cbf718683"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04422e0a-1952-422d-a201-5fafef1875db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04422e0a-1952-422d-a201-5fafef1875db"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "cd6959a3-3d4c-4eae-aeee-0c9406c769c6", "name": "tr(r:p1rdt6273-p1rdt6273lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d04f281-f394-432b-8b5c-cc1acb741369"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07992f45-0c92-4a10-837d-4f58599d9b75"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "55aac547-fb88-4aa6-8809-ecd9a876ffa4", "name": "tr(r:p1rdt6274-p1rdt6274lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a53624b-8538-4cce-b588-c774875af31b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1db8c80-e791-4c31-a6f2-713aa665bf41"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1db8c80-e791-4c31-a6f2-713aa665bf41"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "0ba41d6b-5061-4da6-a3ac-bb25ac6bf459", "name": "tr(r:p1rdt6275-p1rdt6275lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08d4c459-5bc5-4cad-8e74-613c4a08cb35"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba567584-fbee-44eb-b3f1-da24a0ce66a0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba567584-fbee-44eb-b3f1-da24a0ce66a0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "0dd85bf1-32ee-4efa-9b79-2c455df5d785", "name": "tr(r:p1rdt6276-p1rdt6276lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "315af04d-a032-43a8-a2da-b9e68fd21f39"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f20ace2-5ec8-4451-b7e7-66f46c2c487b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f20ace2-5ec8-4451-b7e7-66f46c2c487b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ecf6f04d-159d-4f51-bf3e-799ca3b33afb", "name": "tr(r:p1rdt6277-p1rdt6277lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1dd4f893-7921-41c3-9e9e-d33e3680a999"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e582b04d-a8d8-4ee9-8576-1e5941623c0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e582b04d-a8d8-4ee9-8576-1e5941623c0b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "8e37ba75-2f21-4e53-a316-b5fab0dd5024", "name": "tr(r:p1rdt6278-p1rdt6278lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51eefb94-724e-4dfe-9823-0f6cf8f56101"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b37eabc-787a-491f-bc4f-956f43a862ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b37eabc-787a-491f-bc4f-956f43a862ff"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4a4f2957-d5d5-4b14-b64a-3c47edce713f", "name": "tr(r:p1rdt6279-p1rdt6279lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "632d8db5-5220-4188-94f0-f6131253820b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6614f5e-517f-46cf-b049-09337d57228a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "6f6b8188-d30e-42a1-93eb-2a1b1bc0bdad", "name": "tr(r:p1rdt6345-p1rdt6345lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40280da5-767c-4610-b6a8-ff411e1c33e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a38eb6d-a625-42a1-95f6-bbf078d1447a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a38eb6d-a625-42a1-95f6-bbf078d1447a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "70aa8f42-99ed-452a-b36c-f06fa56744da", "name": "tr(r:p1rdt6347-p1rdt6347lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7166849-6ecd-4270-bf52-d0579838336a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e40008af-ff50-42bd-8897-f663c27a436f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e40008af-ff50-42bd-8897-f663c27a436f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a13e6c46-4605-4824-91c2-352fb915a87b", "name": "tr(r:p1rdt6348-p1rdt6348lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d6c5b78-35c4-475a-8837-776dea236c95"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d84ac329-f314-41be-a2ee-89bc74789a18"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d84ac329-f314-41be-a2ee-89bc74789a18"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "4ff0e214-7067-4064-9386-9806caf80eaf", "name": "tr(r:p1rdt6349-p1rdt6349lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c1edcfa-e0e4-4493-a9bb-e6033185ce67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdfa0310-7dc5-4181-a64e-cc2522370547"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdfa0310-7dc5-4181-a64e-cc2522370547"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "11b74794-1c6f-47e4-a54f-433e3831c90c", "name": "tr(r:p1rdt6350-p1rdt6350lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c935f1c0-e36c-407d-a2e8-4181c4b0733e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0138b892-d18e-497c-9857-c4d5676deac2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0138b892-d18e-497c-9857-c4d5676deac2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4cd1169b-f163-4253-b934-0f8715170853", "name": "tr(r:p1rdt6353-p1rdt6353lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e51e0d9-24b6-40ac-859a-51ea74c93e76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "015322ae-7712-488f-9569-33fc785e4f62"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "015322ae-7712-488f-9569-33fc785e4f62"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c6442bf3-7517-47a1-a505-20f615795f42", "name": "tr(r:p1rdt6354-p1rdt6354lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a05e7c9-4bff-46fd-b356-8120b481b053"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f06a08bd-05ea-4914-b0d0-07cd0e83bfbc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f06a08bd-05ea-4914-b0d0-07cd0e83bfbc"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a2e09203-34e7-4304-9ef8-79ced26ee5cf", "name": "tr(r:p1rdt6355-p1rdt6355lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "88cc1382-6b14-4500-8a21-662fce6a0c0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1d14a79-4d18-43fe-8790-57ea9adf83a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1d14a79-4d18-43fe-8790-57ea9adf83a8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "7a9d98cb-9394-474e-837a-3acb6f94652b", "name": "tr(r:p1rdt6356-p1rdt6356lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1bdfc1ac-98a4-43dd-bb2c-837d0a2c15f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "548724aa-110a-428f-b71a-acdf0051dc39"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "548724aa-110a-428f-b71a-acdf0051dc39"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "058d6f19-56cc-412c-b1e5-cbcabe0dc8ca", "name": "tr(r:p1rdt6409-p1rdt6409lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42929633-40d4-4e13-a0aa-a7682f328226"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e36cfaaa-3996-4cc6-aa4f-170f20c5d1e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e36cfaaa-3996-4cc6-aa4f-170f20c5d1e0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a340529f-91b6-49c6-9dca-e2917c92ce4f", "name": "tr(r:p1rdt6498-p1rdt6498lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5c5466f-b7e4-4844-967b-9e8b11c68b44"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "e9dd0225-3992-43ea-8011-c92f7dd12ae0", "name": "tr(r:p1rdt6499-p1rdt6499lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "89434ebc-1e79-4414-9925-1a14f8e72fd6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb05d831-1556-4f56-8065-d9d16657caa3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb05d831-1556-4f56-8065-d9d16657caa3"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "78d55ca8-45d5-442d-8aff-41943123d90d", "name": "tr(r:p1rdt6500-p1rdt6500lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78b3b940-c277-441f-b2b3-83525ed85fcb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a20a4242-8a76-49f3-9bf5-3d7aaf751cdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a20a4242-8a76-49f3-9bf5-3d7aaf751cdc"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "4f669b5d-d8e9-463a-b26f-2a4ee9987301", "name": "tr(r:p1rdt6501-p1rdt6501lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99fa55d1-867c-4db0-8697-b532da10d6d4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "5b183af9-59bd-450e-bea6-e545db99accd"}}}}, {"uuid": "34a8f0cc-8b8d-4cbe-a72c-4953ada66769", "name": "tr(r:p1rdt6502-p1rdt6502lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e6348d4-7fcb-4546-af84-8ece75b6332f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7682e9f7-1272-4781-b128-34c7329afe49"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7682e9f7-1272-4781-b128-34c7329afe49"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d400dd14-c9f5-47a1-b904-0451078eb91b", "name": "tr(r:p1rdt6505-p1rdt6505lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb1c1e50-902d-443d-8c9a-b728d2f6b6f1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387e7785-8d40-4ddd-8c2b-14a83d4e7401"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387e7785-8d40-4ddd-8c2b-14a83d4e7401"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "aa0dde85-1b90-4171-9964-b45e0fba3d62", "name": "tr(r:p1rdt6507-p1rdt6507lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0db3e719-4dba-4b45-af70-c35546c19eb4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5844baa-5e0f-4edd-9122-fe4255adad0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5844baa-5e0f-4edd-9122-fe4255adad0b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "30e44c45-a02c-4cea-8908-3cc302637263", "name": "tr(r:p1rdt6508-p1rdt6508lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e165d0d-3f13-4d87-9c4b-fdfa8829f1f3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "e492a34f-e6bb-4fe5-81a5-90fd87eabde0", "name": "tr(r:p1rdt6509-p1rdt6509lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67c889f-e940-4242-9c83-4b5ab673d8a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f817a28f-c650-4eb4-84c0-751fe5053c75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f817a28f-c650-4eb4-84c0-751fe5053c75"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "c9ced24a-5b5b-4df7-8d09-09dd0242098b", "name": "tr(r:p1rdt6510-p1rdt6510lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "848c04de-e4d5-4520-9dce-0073776c2ae4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d62fe3b-7644-46d1-8a15-e86d95ae8b2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d62fe3b-7644-46d1-8a15-e86d95ae8b2a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "5b183af9-59bd-450e-bea6-e545db99accd"}}}}, {"uuid": "c4d3abcf-3d44-4600-8d3d-8ecbac558601", "name": "tr(r:p1rdt6512-p1rdt6512lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f7572ed-6443-4e6e-8fb8-0b060b9f17ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "c95fd30e-d8ee-4e73-8137-8809191cc304", "name": "tr(r:p1rdt6514-p1rdt6514lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0737f6ec-0d5d-4cff-b4b7-9910c7076984"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad6bef77-8f39-43b4-b2d7-58aa6e45a60b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad6bef77-8f39-43b4-b2d7-58aa6e45a60b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "f8a778f3-59c0-4bec-8421-fe311691a98e", "name": "tr(r:p1rdt6515-p1rdt6515lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1537ab1-dc7c-4bbd-b347-fc740d54fcf7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b92f8bcd-91ce-42bd-be69-0b43cb9d4122"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b92f8bcd-91ce-42bd-be69-0b43cb9d4122"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "04865f1a-c24c-4c01-9c2c-2f0900f03c59", "name": "tr(r:p1rdt6516-p1rdt6516lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5bd908fd-8bb8-42c1-8d1b-27c4e2574450"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "119a8559-8e6c-4314-9bbd-37ef3adde415"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "119a8559-8e6c-4314-9bbd-37ef3adde415"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "28fdc699-4ca3-4224-ab12-104819ba90f7", "name": "tr(r:p1rdt6517-p1rdt6517lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b56340a0-81f0-4028-9283-532f0d92a412"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5783bae9-2c74-473f-bf18-db40bc975409"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5783bae9-2c74-473f-bf18-db40bc975409"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f389fc04-f3b3-4f77-9b76-fd9e9c700eab", "name": "tr(r:p1rdt6518-p1rdt6518lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d39c608-5688-4e22-8ac4-96b896265274"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b16b03-1922-4aeb-8e70-d0e1387fbcab"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b16b03-1922-4aeb-8e70-d0e1387fbcab"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "ef0eea90-233c-45ea-8067-2c1f4945c601", "name": "tr(r:p1rdt6519-p1rdt6519lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "addd9f38-279f-4d9e-b216-38faef1940c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "606673ea-bcd2-459a-a0af-efb8b31c600c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "606673ea-bcd2-459a-a0af-efb8b31c600c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "59e61f1f-ded0-4c99-a73c-1f0eece1beda", "name": "tr(r:p1rdt6520-p1rdt6520lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24028ccd-3fd3-4461-b83c-54266f91a385"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13c02cd3-cff3-4988-95b9-3993b9541427"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13c02cd3-cff3-4988-95b9-3993b9541427"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "d566312d-edfe-48bf-928b-511d9fa3d857", "name": "tr(r:p1rdt6521-p1rdt6521lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "302d2adf-2199-47b2-9f3c-e428bb409b6f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0e4e42c-8dcd-47be-bfe8-b8b1eb4a5f24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0e4e42c-8dcd-47be-bfe8-b8b1eb4a5f24"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "01a96d6a-0929-49a6-b5bb-16ac567b9a88", "name": "tr(r:p1rdt6523-p1rdt6523lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b540c710-395d-4a35-8dc3-59d37609df09"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66df2481-ae4f-4f39-aef4-7af09ce1a8fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66df2481-ae4f-4f39-aef4-7af09ce1a8fb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "4121aff5-c528-4441-9261-8852d46e58af", "name": "tr(r:p1rdt6524-p1rdt6524lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ef8c502-c06f-43e5-90e6-23bd0ebcf155"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ec2137a-f978-4808-a023-21f13464998b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ec2137a-f978-4808-a023-21f13464998b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "0913bb9f-6019-467a-9487-635b1c029c69", "name": "tr(r:p1rdt6527-p1rdt6527lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "483b2d65-b496-4c6f-b01d-66aa3d9d4334"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8905812-7e3b-4875-87b5-da95999c5bb0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8905812-7e3b-4875-87b5-da95999c5bb0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "516355b6-65e5-4e7f-96cc-f5f66a86fee1", "name": "tr(r:p1rdt6528-p1rdt6528lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ef5115d-ad7b-4671-b984-b9fd5969bf61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d097d9be-dd3a-4616-a873-8ab5013c4e72"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d097d9be-dd3a-4616-a873-8ab5013c4e72"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "314abd89-9ffb-4e76-bde9-35cd4f3410d0", "name": "tr(r:p1rdt6530-p1rdt6530lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40ec7437-80f0-49e8-806a-c696b1402713"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4ee2d3a-e97c-4ec4-9fa0-d7db1b3e9253"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4ee2d3a-e97c-4ec4-9fa0-d7db1b3e9253"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1e893589-336e-4ed7-ae34-9ffb1e76b82b", "name": "tr(r:p1rdt6531-p1rdt6531lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "385eabe4-8c8e-4354-96ec-931e6c25574d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf4a2da0-682a-4119-b398-feaa6f5a8498"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf4a2da0-682a-4119-b398-feaa6f5a8498"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "aaf01e94-e631-4cbd-9b80-5dd82eae3e7f", "name": "tr(r:p1rdt6532-p1rdt6532lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9f12ed7-454c-4cc9-a631-377121a07ba5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0c3e71a-52a1-49b9-a899-c13d639ac0a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0c3e71a-52a1-49b9-a899-c13d639ac0a6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "16c6d40c-8621-46f3-a9d9-eb9f155486b7", "name": "tr(r:p1rdt6535-p1rdt6535lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b13053e-033e-4fe9-8eb3-89389e4bdc2b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10f0e9fa-75b8-4eaa-a2ad-b6a3fb4ae859"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10f0e9fa-75b8-4eaa-a2ad-b6a3fb4ae859"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "1636c5ab-0f83-47b9-b0b9-95c17d558f42", "name": "tr(r:p1rdt6536-p1rdt6536lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f5cda74-5e33-4c52-8b2c-76bcd5e6c5cb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b93e7299-60a4-49d6-9d34-885860588861"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b93e7299-60a4-49d6-9d34-885860588861"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "81e7d228-2f50-4e9c-a1a5-06c06422eaec", "name": "tr(r:p1rdt6537-p1rdt6537lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "902291fa-9561-4f40-a4b7-4fd9fdded417"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3f191ff-f8f2-4f13-af83-e67d1fdd366a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "a14a1967-2de3-44cf-b403-5c2c78717e13", "name": "tr(r:p1rdt6539-p1rdt6539lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9707f264-8f82-4483-8337-6c89d709faf7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b34f50ff-9a1f-439e-81a8-dfcee658926b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b34f50ff-9a1f-439e-81a8-dfcee658926b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "0982378f-fc34-40cc-8889-8feb46b3d3a3", "name": "tr(r:p1rdt6574-p1rdt6574lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25a9ec20-35b9-4262-a02d-cafa63e5ee42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a43920a-a200-40fe-b5b6-3cdba0c7e784"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a43920a-a200-40fe-b5b6-3cdba0c7e784"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "078928ee-8198-4b34-9e44-3d2464af89ec", "name": "tr(r:p1rdt6581-p1rdt6581lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "599c6ed9-5ff7-4c97-a469-adceecaaf902"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "608e485b-13ce-493b-be96-ab83ad733c92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "608e485b-13ce-493b-be96-ab83ad733c92"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "f15ffb13-3e9f-44b6-9603-dab244b5181f", "name": "tr(r:p1rdt6847-p1rdt6847lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e92b102-eaee-41cc-a2fc-c6c4b3bfb58b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7b9897e-b820-424c-adf8-7416de585357"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7b9897e-b820-424c-adf8-7416de585357"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "e3df7eb1-aff6-4359-acc7-d144d166201d", "name": "tr(r:p1rdt6848-p1rdt6848lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96399e51-1243-4e7f-ae3a-5e2c67123aae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94c9fa37-fc5c-4243-b0ca-f70840febaee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94c9fa37-fc5c-4243-b0ca-f70840febaee"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "d992636b-1b45-4cf4-9b69-e4a53bf53fdf", "name": "tr(r:p1rdt6995-p1rdt6995lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3741c9d4-d03a-4b2f-be57-52a8977351ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09a476ff-48a0-4d27-9cf0-c007e2e98acb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09a476ff-48a0-4d27-9cf0-c007e2e98acb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6973bac5-8bc7-4183-ac29-4d1c42f19e00", "name": "tr(r:p1rdt7015-p1rdt7015lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6278a0d-f5d3-4b11-aee9-3bb23f9954a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "536d7c56-85a6-4167-b4f6-2f39936cd662"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "536d7c56-85a6-4167-b4f6-2f39936cd662"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a0c75282-007a-41ab-9904-5fad1ba4ac01", "name": "tr(r:p1rdt7036-p1rdt7036lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52068090-b613-46d7-a31f-ad3ca26382d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a371c8b-1993-432c-b2c6-21b18bec27da"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a371c8b-1993-432c-b2c6-21b18bec27da"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "2d40d74c-19e5-4154-811a-bf6f0c3b4793", "name": "tr(r:p1rdt7038-p1rdt7038lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb3a9847-70d0-4004-95ef-63884c6c1cdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "046f6c53-8d9c-43a1-88ce-169ade9e9557"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "046f6c53-8d9c-43a1-88ce-169ade9e9557"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "57d5d60c-4bbd-4830-b62b-aef430bbbb13", "name": "tr(r:p1rdt7046-p1rdt7046lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9bb8596a-bcb2-4282-bf1b-9939a9af87d9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cd6a9808-9889-4f16-825d-c9763357c293"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cd6a9808-9889-4f16-825d-c9763357c293"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "88d0b3b4-df75-431e-a234-b9c4c40cd0f7", "name": "tr(r:p1rdt7054-p1rdt7054lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3cf406b-69e6-4aee-a6fc-272dad7693a4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf93e681-3ab6-4929-95f1-1da6d5dd28fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf93e681-3ab6-4929-95f1-1da6d5dd28fa"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9d5af3ee-6de8-428a-bce8-ff4ba5108c9f", "name": "tr(r:p1rdt7061-p1rdt7061lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75947ffd-3765-443b-bef8-b6af746ef624"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc33ade7-4471-40b8-8e9b-1846e0ad60e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc33ade7-4471-40b8-8e9b-1846e0ad60e8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "7b8e2373-7990-4ad0-ac7b-fea580be3edb", "name": "tr(r:p1rdt7067-p1rdt7067lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b470fa62-70d4-4cc5-8f7e-b9cda37481e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ff878e1-3143-4f8e-aa92-74d0a9046417"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ff878e1-3143-4f8e-aa92-74d0a9046417"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "c5a5b6ad-87d0-4856-83d7-f4e3fd1bf17a", "name": "tr(r:p1rdt7069-p1rdt7069lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aae22557-7d34-401d-82c9-2d2710ff2915"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a1566f1-7f0d-41d7-adad-425c9a344eb0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a1566f1-7f0d-41d7-adad-425c9a344eb0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "74945b57-66b3-460b-8963-4876d9317ea5", "name": "tr(r:p1rdt7070-p1rdt7070lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac6e8ccf-75ec-42e0-a3cb-9ab86e2731a4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "844bdc22-2e32-43ee-8e0b-26f3f4c107b8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "844bdc22-2e32-43ee-8e0b-26f3f4c107b8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "56ede37f-8654-4ee4-98d5-b4ca3c882a01", "name": "tr(r:p1rdt7075-p1rdt7075lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8cebb186-4d9e-4d2c-b0d9-100056d34942"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e0577c2-8275-4303-ad11-2c4f56df3f5c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e0577c2-8275-4303-ad11-2c4f56df3f5c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "3c44ca10-17d2-4bc0-8731-abfad4747034", "name": "tr(r:p1rdt7080-p1rdt7080lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "662e2a1c-9a54-4ac3-b478-98e3a478349d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d86bd7f-7759-4d74-9c74-d58010498f92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d86bd7f-7759-4d74-9c74-d58010498f92"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "23574f4e-125b-4c27-9e9f-edd96225a600", "name": "tr(r:p1rdt7087-p1rdt7087lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f614382d-3883-4f6b-b1f6-c8e83d84ee22"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d0c96fe-78c2-4303-ac5c-bbe440f19666"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d0c96fe-78c2-4303-ac5c-bbe440f19666"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "fe0147a8-371a-4e44-a456-842e99895e5b", "name": "tr(r:p1rdt7088-p1rdt7088lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac70c13b-5f4f-45f3-880a-b4b476ea552a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f1652e8-6cf7-43d4-8474-e61a74873675"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f1652e8-6cf7-43d4-8474-e61a74873675"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "49996ff9-e4f6-4f1f-abb7-8f8f1d042cb6", "name": "tr(r:p1rdt7089-p1rdt7089lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31cd4834-477f-4060-8efd-0504c8e8eaa9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73cfcce9-a925-4f29-9cde-6dd6f50735e1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73cfcce9-a925-4f29-9cde-6dd6f50735e1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "625b6c93-5baf-422e-bbe0-ac474e8c21b5", "name": "tr(r:p1rdt7090-p1rdt7090lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08d3a02a-555d-4ad1-9b13-d413b7a16eef"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d6a4c80-d261-4350-8224-8fe5191459c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d6a4c80-d261-4350-8224-8fe5191459c7"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c9e88619-7030-488f-8581-b184ead99804", "name": "tr(r:p1rdt7091-p1rdt7091lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6372a592-5e2d-41c8-819b-f56bfbb58e19"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0c42b48-7ca4-465f-b17c-048cb5f6d79b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "900a59fa-b9e1-4d82-96ad-d7a0e70edd73", "name": "tr(r:p1rdt7201-p1rdt7201lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f64ed4a2-6afb-447c-8c6b-15935e050a6d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6718b871-3967-4c29-83e5-441799c7fb92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6718b871-3967-4c29-83e5-441799c7fb92"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "ebdb125c-15f7-4ac7-8898-a0749c1a885a", "name": "tr(r:p1rdt7220-p1rdt7220lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a2f1a631-48f7-4291-9adb-588a66620ebf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d5e45d6-867a-4442-8258-2c04891dbc4b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d5e45d6-867a-4442-8258-2c04891dbc4b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "46e0dc9d-bf0c-4247-8399-4bba2bf59842", "name": "tr(r:p1rdt7224-p1rdt7224lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eeab7dfa-540c-4275-b159-f6ac4d1350f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d6a6156f-e72a-41f0-a307-e6030de24fde"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d6a6156f-e72a-41f0-a307-e6030de24fde"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c6728992-0569-4ad6-a2ee-a89c059a8cb9", "name": "tr(r:p1rdt7248-p1rdt7248lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a006c5f-e960-4ae2-a37f-d23d7b873a22"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2087cee5-9f6e-4400-8ca8-bbb120cd4dae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2087cee5-9f6e-4400-8ca8-bbb120cd4dae"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "c26eb6ec-9734-4824-8244-a225695d909b", "name": "tr(r:p1rdt7253-p1rdt7253lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f31b09da-e4cc-409e-9634-1907480039ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b4f7df4-5453-459d-8599-48fd5f29a9c6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b4f7df4-5453-459d-8599-48fd5f29a9c6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "13b3b35f-051e-4e07-9ad6-700afdf01778", "name": "tr(r:p1rdt7268-p1rdt7268lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a21680f1-33a7-44e1-9293-98c6861ba2a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1130272e-b98e-496f-aeb9-c094cf9cd824"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1130272e-b98e-496f-aeb9-c094cf9cd824"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "2bf5204f-ad9c-4982-ae22-74ef1aeca8c5", "name": "tr(r:p1rdt7298-p1rdt7298lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b658bf21-450c-4e6b-9dec-c5023a05fd19"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d304e5e0-2cc1-4167-9fad-6fc72228d828"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d304e5e0-2cc1-4167-9fad-6fc72228d828"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "8b3fc746-d9f0-45d0-ad16-d61574e7758f", "name": "tr(r:p1rdt7301-p1rdt7301lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84200441-4c26-4966-a4b7-6b91fb43f02e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43df4c14-a198-4d51-87f4-80000198cd47"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43df4c14-a198-4d51-87f4-80000198cd47"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f3cf9fd8-981a-45c4-8d3c-5f8be4e28074", "name": "tr(r:p1rdt7302-p1rdt7302lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a65c4d3-2fc6-48c8-b944-68c4229db3dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e2a141f-436a-45c0-9c15-179301a439c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e2a141f-436a-45c0-9c15-179301a439c8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "64a649e8-0397-468e-8602-656f8d0a2792", "name": "tr(r:p1rdt7306-p1rdt7306lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "607c7275-da9a-4620-b019-59a66e98c2e6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0926064a-1c87-450a-b282-23708de8aec4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0926064a-1c87-450a-b282-23708de8aec4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "0d51ff9e-3968-4c9c-b1a5-f15632d49f89", "name": "tr(r:p1rdt7307-p1rdt7307lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "231b5cf9-ec2c-47d1-aada-5454926561dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ce9dd2c-9e17-46b7-a6f4-e85077664432"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ce9dd2c-9e17-46b7-a6f4-e85077664432"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6a3a1abe-b81d-478b-9726-5826aada08d9", "name": "tr(r:p1rdt7311-p1rdt7311lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3a4dfb4-e1b3-43b9-ae42-b0cec47ff4ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2d6046b-9ece-4295-a180-41bf2ce47ce6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2d6046b-9ece-4295-a180-41bf2ce47ce6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9d5b01f2-1d26-4772-9ec5-58ed8abd8ee8", "name": "tr(r:p1rdt7313-p1rdt7313lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a3a5e1c-77a2-4a9d-89e0-7d1c94176787"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41e61263-feb6-4264-965a-fd1309d997a1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "34cd711d-2476-4079-bee1-db83e6e89155", "name": "tr(r:p1rdt7314-p1rdt7314lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0cf1844f-a32e-40f2-bc96-05fad3bdd88d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97844fdb-b016-4ca3-8777-b0553ead9297"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97844fdb-b016-4ca3-8777-b0553ead9297"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "92d3cf9e-563c-4377-b3aa-ebfc60ed645e", "name": "tr(r:p1rdt7318-p1rdt7318lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e86bc267-1607-4aa3-916f-ed826b0adfdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22b1ecce-d5df-4f42-abb2-9f4c3d3a28c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22b1ecce-d5df-4f42-abb2-9f4c3d3a28c5"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "0b6fafe7-545d-452c-b7f3-62b2c442f7dd", "name": "tr(r:p1rdt7550-p1rdt7550lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dead8520-e2f5-499b-9316-77780f9b1dfe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58be5cbe-5a7c-4fa5-972d-e03100b3bb46"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58be5cbe-5a7c-4fa5-972d-e03100b3bb46"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4fbe1b16-45a1-4f4f-b54c-4bd9dacab9b2", "name": "tr(r:p1rdt7551-p1rdt7551lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f0f3112-1395-48bf-88c1-8dd4b171478d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c4d7ee3-fc5d-4a17-a717-3d6b6d5a67ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c4d7ee3-fc5d-4a17-a717-3d6b6d5a67ae"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f6bb901b-e888-474e-937e-b47c34f55eec", "name": "tr(r:p1rdt7552-p1rdt7552lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db899c48-a801-4f83-b59d-e587ba80019d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f5d6708-cef4-4aac-9fa0-c738953c788f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f5d6708-cef4-4aac-9fa0-c738953c788f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9ef9d653-e17c-46b4-b8eb-308dcc2d2329", "name": "tr(r:p1rdt7553-p1rdt7553lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddf629eb-ea60-4fce-b731-7ebb33665829"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7a672b2-d127-4fb5-8cc4-8115b8ef3f60"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7a672b2-d127-4fb5-8cc4-8115b8ef3f60"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "1ad1e6cb-ac02-4298-94d9-b6e7b217363f", "name": "tr(r:p1rdt7554-p1rdt7554lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f6de990-0988-4126-86ca-d1fd72c555fe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86a6d184-d883-4e27-aee5-b89c82163284"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86a6d184-d883-4e27-aee5-b89c82163284"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "bd4532f5-197c-4d9d-88b6-69e85596cebd", "name": "tr(r:p1rdt7555-p1rdt7555lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0075333-98fe-4ee8-bb64-a18119b817c0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0de9c581-b78b-44d6-8693-59b995e2a3bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0de9c581-b78b-44d6-8693-59b995e2a3bb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6236b757-e2d7-4dc9-9418-64e399e056c9", "name": "tr(r:p1rdt7559-p1rdt7559lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f239ef4e-83f0-4a2c-ada3-8e30cef38472"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b593ec6-e1e3-48c2-b352-f7966f206aa9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b593ec6-e1e3-48c2-b352-f7966f206aa9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1d28deb4-7339-4686-a9aa-b3814787aab1", "name": "tr(r:p1rdt7561-p1rdt7561lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc6bd64f-1ad3-4bd9-b590-7d4b673a94b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05e30abd-3c40-4dbd-9261-ca8a8abd9c56"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05e30abd-3c40-4dbd-9261-ca8a8abd9c56"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "bb32295e-91d3-4b0d-a30b-f527438019eb", "name": "tr(r:p1rdt7564-p1rdt7564lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa33ca9e-e16d-4c49-8a70-c6c30cf7b038"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7588b3b-f54c-483d-b354-b9908483019a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7588b3b-f54c-483d-b354-b9908483019a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "38f3f4b0-05b8-469e-9bf4-9aa64b723b84", "name": "tr(r:p1rdt7570-p1rdt7570lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9b94106-b7c5-4ce9-9c19-053487848c2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2b3b9e1-3d98-44c1-bd38-9325623a1553"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2b3b9e1-3d98-44c1-bd38-9325623a1553"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c839a693-631e-43a1-943f-063d3e8cac8a", "name": "tr(r:p1rdt7572-p1rdt7572lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4307e78-304a-4175-8e81-9cb23d99f394"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69bf048e-54cd-4e41-a23e-485b0cd98fae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69bf048e-54cd-4e41-a23e-485b0cd98fae"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "14f1f8fd-687c-4967-a86b-790552e9bb2b", "name": "tr(r:p1rdt7574-p1rdt7574lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd487832-bc77-406f-a995-4b099fad7c64"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a742708-0f8b-42d0-a977-b5ce5e36a042"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a742708-0f8b-42d0-a977-b5ce5e36a042"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "40be45f1-06bb-4504-b1e8-03427c7e92c8", "name": "tr(r:p1rdt7576-p1rdt7576lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b28595b-dcbe-4d1b-92c4-94acf370bb1f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56b05024-7907-458d-a5c3-0e54ffbabdb5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56b05024-7907-458d-a5c3-0e54ffbabdb5"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a60ca7e5-fadd-4a55-9aaf-a6336c346d87", "name": "tr(r:p1rdt7579-p1rdt7579lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76f6a27f-0e4f-48b8-9dbd-31c6ffc4ec75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d00b7fe-0384-4c12-a0cf-8895458d3b80"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d00b7fe-0384-4c12-a0cf-8895458d3b80"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "dd238be0-3718-42e1-a1c0-47e911dee99f", "name": "tr(r:p1rdt7588-p1rdt7588lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f2dabc2-0b52-490c-b13a-32c268f6bd33"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abc940b0-c9f5-4582-adaf-ad7f4a79a35f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abc940b0-c9f5-4582-adaf-ad7f4a79a35f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "306bd8de-2bed-4392-b5cd-af1639de22f7", "name": "tr(r:p1rdt7589-p1rdt7589lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f9809eb-41e0-40a8-b43a-93556f767f68"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53e9cf92-1c91-428f-bdff-64257257ad5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53e9cf92-1c91-428f-bdff-64257257ad5b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "76c04b04-3f7a-4a92-8244-2b76e218fa05", "name": "tr(r:p1rdt7598-p1rdt7598lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f95e5fa5-a84c-42a4-b519-8d344e816ecd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff1e0d26-d845-43c3-9aaf-01d1c007b9a1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff1e0d26-d845-43c3-9aaf-01d1c007b9a1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b1a1407b-f572-4475-89dd-fdc7487a6303", "name": "tr(r:p1rdt7599-p1rdt7599lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a086b782-3a8d-44e9-9948-cb7f051219e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d838502-3769-4d70-839b-26fd628ce478"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d838502-3769-4d70-839b-26fd628ce478"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "be508024-b14e-4860-a815-fba0b7e63239", "name": "tr(r:p1rdt7605-p1rdt7605lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e36f1f1-6993-46b0-bafa-9530fd1652ef"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3488ff0-696f-4180-bc70-41ff37f9c365"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3488ff0-696f-4180-bc70-41ff37f9c365"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ab99af7f-f37b-440c-88b1-ff14dfa3d7c1", "name": "tr(r:p1rdt7612-p1rdt7612lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3410d88a-3e9c-427e-a79e-5c602455ed1d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fdfea70-187a-4bbc-ba3f-69cb74c4d5c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fdfea70-187a-4bbc-ba3f-69cb74c4d5c5"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "5633eb80-82db-48b3-b73b-40e06940ca5c", "name": "tr(r:p1rdt7615-p1rdt7615lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "105df8ff-ec38-4cd6-b557-c318b4023bd0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "269e9ba5-bc54-4cbd-9140-4b1bea74fc53"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "269e9ba5-bc54-4cbd-9140-4b1bea74fc53"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "20e0b0a7-7df7-4a70-90c4-c2e51e42f8d2", "name": "tr(r:p1rdt7616-p1rdt7616lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7167a2e-9e83-441e-a15b-0256848c3f6d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6af13868-ecb1-4110-be3f-537741287035"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6af13868-ecb1-4110-be3f-537741287035"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "ab1caeed-4f38-4dd1-8946-e1f37a4e07cf", "name": "tr(r:p1rdt7617-p1rdt7617lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01c9d31d-c3bb-4950-9bbd-00377c252ddc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4be4af94-fee7-40d6-9061-9a0fe0e7377e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4be4af94-fee7-40d6-9061-9a0fe0e7377e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "48f92b1a-dfcd-45a9-a9c8-46f9c5a3464f", "name": "tr(r:p1rdt7618-p1rdt7618lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0fef9b3-a4bd-421c-8a54-cbf6f44c460d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49f37435-54fc-42b4-baba-94f0611c8c76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49f37435-54fc-42b4-baba-94f0611c8c76"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9ba2159e-0ded-4752-ab15-e81614b1a3f6", "name": "tr(r:p1rdt7619-p1rdt7619lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "161d6f3b-8bd9-4fa8-9442-c6ff008e8d3d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a205379-48f9-444c-baf8-dc84fc9c6d8a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a205379-48f9-444c-baf8-dc84fc9c6d8a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ceab5e31-ac40-491f-8469-d2987e18c247", "name": "tr(r:p1rdt7620-p1rdt7620lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97be7ac3-a710-4de8-a666-276813582cd6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af91c50-929d-4ac6-9272-7c44d17a0094"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af91c50-929d-4ac6-9272-7c44d17a0094"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "bdcbb6b6-4e44-48e9-8d5b-4602c5816566", "name": "tr(r:p1rdt7621-p1rdt7621lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa48cf27-3b07-4460-ad9c-8d9862238645"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60f0bddf-6e4b-495c-a98d-f3940d69a5e9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60f0bddf-6e4b-495c-a98d-f3940d69a5e9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "654c6e8e-e5cc-4433-b8a9-4f1e0ff9afb9", "name": "tr(r:p1rdt7624-p1rdt7624lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e240270-762d-49f0-a4e4-29fcd6273ce5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e2075fb-9691-447e-9a73-f88649310bc1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e2075fb-9691-447e-9a73-f88649310bc1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "3e444053-e0f6-4c5e-b83a-778c710b6246", "name": "tr(r:p1rdt7625-p1rdt7625lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3e6cbe9-d1d3-4c59-981f-dad980f0999b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6b1e3b6-ce3a-4ad6-a046-6608530b2ec2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6b1e3b6-ce3a-4ad6-a046-6608530b2ec2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b3029529-3d87-4bf6-855d-9e4acc2459cb", "name": "tr(r:p1rdt7626-p1rdt7626lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56d67e3e-46af-4e2c-86a8-191d97b0ce8a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56f8eed1-77ae-4d65-80aa-7ae148350333"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56f8eed1-77ae-4d65-80aa-7ae148350333"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9123f9a8-9439-48d0-8966-b3c4d4d710e1", "name": "tr(r:p1rdt7627-p1rdt7627lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5bddd75e-1974-41ee-ab51-625c7485a573"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90d8891c-6e6d-46b9-8f88-acc9453c6541"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90d8891c-6e6d-46b9-8f88-acc9453c6541"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9afa56ce-eb98-472e-a5c6-91206e1a8521", "name": "tr(r:p1rdt7630-p1rdt7630lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "723e2b5c-414c-4f3d-ba23-d2df4bc63e75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ad2599f-313b-49c6-abaa-19177e1a9edc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ad2599f-313b-49c6-abaa-19177e1a9edc"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b9fc1aba-239f-4d0d-8085-2dd63d6da04b", "name": "tr(r:p1rdt7631-p1rdt7631lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9e53141-a773-4127-9558-3887070a8f36"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4861056b-b634-4900-94bb-d6c995387351"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4861056b-b634-4900-94bb-d6c995387351"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "752c4be4-3b4b-44b4-ae38-4efa162ae539", "name": "tr(r:p1rdt7632-p1rdt7632lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36e7cd28-6795-41d5-847d-92347871384f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7235cf3a-dd26-47f7-884c-6335024a3064"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "e911abc7-52f8-4093-a459-c3ca4018ece3", "name": "tr(r:p1rdt7699-p1rdt7699lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec849ee4-3d69-46a9-9a2a-242a3943e46c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bfa76dc8-4007-4e52-9692-2eec7cb574e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bfa76dc8-4007-4e52-9692-2eec7cb574e0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f4c59d36-a424-406c-abe0-7ec431462ff8", "name": "tr(r:p1rdt7701-p1rdt7701lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "74968ebc-53c5-4fc6-8172-3ffa9dea7683"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0cc95d09-c799-488e-81e8-50326a7da1ea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0cc95d09-c799-488e-81e8-50326a7da1ea"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "76f31e46-6028-4e28-9c78-d861c071c648", "name": "tr(r:p1rdt7704-p1rdt7704lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02ea9067-6a2a-48b6-b5f1-10992b9fbd77"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ef392d6-b408-4a7f-8a67-9fe43e1df582"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ef392d6-b408-4a7f-8a67-9fe43e1df582"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "aded564b-854a-4916-b3de-3ee4098f53f2", "name": "tr(r:p1rdt7712-p1rdt7712lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4462b9c6-748f-48e9-9ff9-7f20a06cf456"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59a62487-c709-428e-9e97-c7c285a1305c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59a62487-c709-428e-9e97-c7c285a1305c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ac1905ca-2d2b-4806-8ad1-5ac7cd2f4526", "name": "tr(r:p1rdt7718-p1rdt7718lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "048e2bab-67f2-4975-81a1-bbc9f2f9cd88"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6d10a4e-e7bc-4448-bca3-a5f2117b6198"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6d10a4e-e7bc-4448-bca3-a5f2117b6198"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a39660fd-d276-4af3-afe6-1cd2ff97fa07", "name": "tr(r:p1rdt7735-p1rdt7735lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62078787-3ae2-47b3-8f67-8e89e110c8be"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96dcd934-01a0-4719-89bc-a18430edf179"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96dcd934-01a0-4719-89bc-a18430edf179"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "ce2cab85-3bda-4e0e-9cbc-d2bea2fe03e1", "name": "tr(r:p1rdt7790-p1rdt7790lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97198258-8ba3-4950-8747-3241c6a4fcee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ed564b5-8d49-4ff7-94c2-b245981472e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ed564b5-8d49-4ff7-94c2-b245981472e8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c43106ec-5430-410d-a310-0f90dbe8b582", "name": "tr(r:p1rdt7954-p1rdt7954lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21e15d54-eab8-4204-9ed6-407fd8684700"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9dd5bb5-1410-4635-8a85-d23d7c3e55ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9dd5bb5-1410-4635-8a85-d23d7c3e55ad"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9cba1db2-bbe9-438b-a0ae-cbe9c6042c84", "name": "tr(r:p1rdt7973-p1rdt7973lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "016e4575-cd41-4993-be9b-5e5236a139ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3a96167-4b09-49c9-baf7-4fb588ecb002"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3a96167-4b09-49c9-baf7-4fb588ecb002"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "73995ff5-d40e-411d-80e1-03503328178f", "name": "tr(r:p1rdt7983-p1rdt7983lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e261b565-1f57-4cdc-bdd6-e045ee55d290"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb63be48-94ec-4c9f-9991-77892e14171b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb63be48-94ec-4c9f-9991-77892e14171b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "ee7e1b81-29bd-4324-bd7f-edb721cfe6d1", "name": "tr(r:p1rdt7986-p1rdt7986lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "93a5388e-ffd7-403e-b6cf-26b7e81feed1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "415fe6e9-953e-40f6-8ae8-43834e4e6ce4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "415fe6e9-953e-40f6-8ae8-43834e4e6ce4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "40ae26e7-8612-4ca1-af9a-6138c75b525a", "name": "tr(r:p1rdt7988-p1rdt7988lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48e4b67a-0a47-48f0-b787-0a639db89caa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94f12107-697c-4278-95e0-32b6eb49fdb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94f12107-697c-4278-95e0-32b6eb49fdb3"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "68d17fd2-4b36-4948-b180-d122e210a188", "name": "tr(r:p1rdt8012-p1rdt8012lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bfb33cd-0cf1-455d-81e7-3d0472fa1b41"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5b22c57-7912-4e9f-9b06-6a8ff706a58d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5b22c57-7912-4e9f-9b06-6a8ff706a58d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "4d09727b-7ad9-4895-b375-82bcd4bbeee8", "name": "tr(r:p1rdt8015-p1rdt8015lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc543f54-740b-4a7f-b1c5-eb3783a8ade0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6c5d7ff-cfcd-4b30-98db-eb44a95d6841"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6c5d7ff-cfcd-4b30-98db-eb44a95d6841"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9312b2f6-1773-4a40-bf4a-1a6db143517c", "name": "tr(r:p1rdt8034-p1rdt8034lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f83d22a-fa1e-4a4e-aab9-a9dea8ee06e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "972fe574-f88e-4a8d-8845-d5baa2f378a7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "972fe574-f88e-4a8d-8845-d5baa2f378a7"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "67d378fb-5a38-42c9-85a2-d6c5d30de182", "name": "tr(r:p1rdt8149-p1rdt8149lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b706c56-20f1-49ed-9cbe-0ec1491b83e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9951633b-4311-4ca2-9316-3801be13fe97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9951633b-4311-4ca2-9316-3801be13fe97"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b0592825-0ebc-47eb-b648-6b5e9eca65f6", "name": "tr(r:p1rdt8150-p1rdt8150lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78081763-07d2-4989-b492-e1c5178c4097"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cd1ae47-6aaa-4b57-ba44-1e74f6ea54b7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cd1ae47-6aaa-4b57-ba44-1e74f6ea54b7"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d471ae12-2ba6-4052-a460-048edfdc8258", "name": "tr(r:p1rdt8151-p1rdt8151lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c794942-d5ce-481f-9c6a-563a2180a4ba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a8deb5-b46b-4d4c-876c-b44b2258a6fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a8deb5-b46b-4d4c-876c-b44b2258a6fa"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "49759203-777f-49ae-b598-ca28caffe71e", "name": "tr(r:p1rdt8153-p1rdt8153lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b44d5021-4fdb-4618-bcb2-237ecf2e10e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a542ca5-b24e-44dc-8b68-c00aa024afad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a542ca5-b24e-44dc-8b68-c00aa024afad"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a7da70e8-efbf-4e0b-a7f7-eeb682445e70", "name": "tr(r:p1rdt8154-p1rdt8154lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42ab6054-1866-49c5-b2ab-3cf27199c1c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32fefbef-e10b-4758-8c2e-ccafad49aa5d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32fefbef-e10b-4758-8c2e-ccafad49aa5d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "cdab182b-63a8-43ed-a657-4a881f34363d", "name": "tr(r:p1rdt8155-p1rdt8155lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1613a53e-5194-4d26-b83b-475d9f02a32c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51812cd8-eec8-4862-8413-d25a7e9862dc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51812cd8-eec8-4862-8413-d25a7e9862dc"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "8e5d5e35-2a37-4ca3-b6d8-ac657a25cc53", "name": "tr(r:p1rdt8157-p1rdt8157lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a30e197-897f-4516-b4e5-f70081e6f8c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa6d4429-8a95-4ebd-9e3a-9867734245bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa6d4429-8a95-4ebd-9e3a-9867734245bd"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9c6e09ab-62cf-4cf2-ad4b-85f28da49b1b", "name": "tr(r:p1rdt8159-p1rdt8159lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42b9c576-ddba-4be1-bc64-a37d8cbdfa84"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1dd4660-3cd0-4709-b1ef-1c598e5e39fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1dd4660-3cd0-4709-b1ef-1c598e5e39fb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "4e23e836-b3c0-414d-8b6b-35675ebd0a0a", "name": "tr(r:p1rdt8160-p1rdt8160lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38b72c12-2e2f-4d83-8f5a-9d8503dc29eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "232fed6b-fe0f-4a44-93e9-e6675b50c39c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "232fed6b-fe0f-4a44-93e9-e6675b50c39c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "36e7363c-1995-4a3a-86c5-a0ace2ea4bd8", "name": "tr(r:p1rdt8161-p1rdt8161lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25946c74-15c2-412c-baed-8de5f7aecf98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac7e489e-7249-4702-9ed6-131cad34500f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac7e489e-7249-4702-9ed6-131cad34500f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "ce00bda5-ef31-4200-abe8-7edb6e2ce469", "name": "tr(r:p1rdt8346-p1rdt8346lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14b429c3-41da-4123-b661-40cbdfaf33e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9560197a-21d1-4601-8bcb-213df4844f4a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9560197a-21d1-4601-8bcb-213df4844f4a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "e76e538a-44eb-4381-8e37-7fb09b2f63a2", "name": "tr(r:p1rdt8405-p1rdt8405lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60829dab-c129-4017-961a-81435d8afa93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "408d5d7b-fc71-46bb-8de0-2d4e628c29b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "408d5d7b-fc71-46bb-8de0-2d4e628c29b6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d7e934e2-03f8-4a6a-ab5d-ad3b3dd48470", "name": "tr(r:p1rdt8408-p1rdt8408lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28af960e-6f27-483a-8029-0c5f1641f51d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3fe0f77-a7c1-48e3-94aa-30b69f20ca65"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3fe0f77-a7c1-48e3-94aa-30b69f20ca65"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "95aaee68-75c3-4a09-afe8-2ae7e6764680", "name": "tr(r:p1rdt8414-p1rdt8414lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b48f78d-1092-4536-bfb3-029da6a70dff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fca92353-c013-4c41-8507-ec8704410834"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fca92353-c013-4c41-8507-ec8704410834"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "2a2e6bf5-cdb1-4881-a7ba-b0751befd246", "name": "tr(r:p1rdt8422-p1rdt8422lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ce65512-7d5f-4514-b55c-1775e80dd94d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfe35c35-8164-4825-81e3-10a2ece2cb27"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfe35c35-8164-4825-81e3-10a2ece2cb27"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "704a77eb-97a5-44a1-ab78-f3e5768a865c", "name": "tr(r:p1rdt8434-p1rdt8434lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f28de397-0db4-486a-8ce6-9f65c68703b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdc5ef2a-c0d0-4702-b6c6-df08af1e8746"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdc5ef2a-c0d0-4702-b6c6-df08af1e8746"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1ccbc567-041b-40ab-b2c1-6da64ae2a300", "name": "tr(r:p1rdt8436-p1rdt8436lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fcc42825-2690-4965-a99b-e78285a9b84e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b24c9345-625f-499d-96cf-30b2de5839b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b24c9345-625f-499d-96cf-30b2de5839b6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "db06099d-51cd-4922-8556-5fc046213ce9", "name": "tr(r:p1rdt8439-p1rdt8439lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07f340ca-58c2-4331-8265-a39a45c87b75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a38f544-e250-4fc9-942c-946c5cde0a33"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a38f544-e250-4fc9-942c-946c5cde0a33"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c1cf0331-e671-4257-a481-22857029dcff", "name": "tr(r:p1rdt8440-p1rdt8440lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bbfe31b1-38ce-4ae4-9143-bf08c81617e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "049362b4-49de-4e80-921e-ff763aaab2d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "049362b4-49de-4e80-921e-ff763aaab2d1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "bb01e69d-d66e-4622-a9d2-49439101442f", "name": "tr(r:p1rdt8441-p1rdt8441lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b423745-cc70-4c3a-adb0-f648170b4ab1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72c8f08a-0ba5-413e-a805-f9436b41ff29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72c8f08a-0ba5-413e-a805-f9436b41ff29"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d9636448-6ac3-4dab-b534-39f3b2189242", "name": "tr(r:p1rdt8442-p1rdt8442lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6700763-e6dc-4626-ac2b-22985f0043be"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b5ae28a-95f8-4023-aa23-36809fe96b10"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b5ae28a-95f8-4023-aa23-36809fe96b10"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "f401dbb6-1c00-4683-a97f-240f0d404ec0", "name": "tr(r:p1rdt8444-p1rdt8444lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "685fbdbf-47af-4cc2-97ce-354dd04ce915"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "978920e8-edf9-4bee-85f9-45f4081ed0ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "978920e8-edf9-4bee-85f9-45f4081ed0ca"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "e78e59b0-1628-44f3-9f40-434870c7485b", "name": "tr(r:p1rdt8445-p1rdt8445lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc0ee90f-1f9e-435e-bac4-86a4688c48fc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e0923da-550b-479f-b3d8-3e0320db6701"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e0923da-550b-479f-b3d8-3e0320db6701"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ba075575-7d34-4581-bd89-580a7809f865", "name": "tr(r:p1rdt8447-p1rdt8447lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13b8cfc1-d8eb-4f47-b024-c1daacf3771d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5dbc3459-6a17-4075-899a-6aab16fb3ab7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5dbc3459-6a17-4075-899a-6aab16fb3ab7"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "68fa5476-e1d3-4fcb-aae1-82554760837b", "name": "tr(r:p1rdt8450-p1rdt8450lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "184f95d4-cde1-4bf1-8a74-ebc7097cb10e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b4216c8-9e99-446c-ad09-5a09f046dd59"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b4216c8-9e99-446c-ad09-5a09f046dd59"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "832c98de-e0df-4a23-a77c-8bae8f9c82a2", "name": "tr(r:p1rdt8456-p1rdt8456lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0089e5ea-d706-4a74-812f-654ae73eabcf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d094b779-ebcc-4837-9ccb-31808e2a544b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d094b779-ebcc-4837-9ccb-31808e2a544b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f1be4587-95df-49ac-b27e-27bf9042374d", "name": "tr(r:p1rdt8458-p1rdt8458lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "433162b1-2a9b-4187-ba28-ec57503d76f6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e597d8da-e876-44a5-a109-1ce84527c557"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e597d8da-e876-44a5-a109-1ce84527c557"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1be9aa15-7b2b-40a1-9e35-67939a2032bf", "name": "tr(r:p1rdt8470-p1rdt8470lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "442de065-9e2a-4ff8-9100-1298d3fe0f6f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "edb15d92-f98a-4fa2-8129-ad8a39e0dc0c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "edb15d92-f98a-4fa2-8129-ad8a39e0dc0c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "978ee383-d478-4f12-a155-7192f5c3a6c6", "name": "tr(r:p1rdt8490-p1rdt8490lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37c41a4b-e439-42a1-b9a7-0582c528f0e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a84e1424-7faf-4077-9461-b39460f10ef0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a84e1424-7faf-4077-9461-b39460f10ef0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "eb250ab0-b078-4fd6-890a-38d97425c873", "name": "tr(r:p1rdt8492-p1rdt8492lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "307d9c6d-d5ee-4490-95d3-5a9b1d171e54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "127e4cc7-6413-4482-9ec3-40f8bde02d0c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "127e4cc7-6413-4482-9ec3-40f8bde02d0c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "325e4fe1-dddd-4f95-bd62-a4992948ea11", "name": "tr(r:p1rdt8802-p1rdt8802lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26ccaeff-3a34-4835-8906-1145148549c6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95a1a7c7-6055-47c9-a742-c1b81f6c7478"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95a1a7c7-6055-47c9-a742-c1b81f6c7478"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "7e8bf118-8d3d-438f-8fad-151a16e1fcba", "name": "tr(r:p1rdt8805-p1rdt8805lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3444af6b-f9d4-4229-b6b2-2114300c3f94"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "715c92fa-2470-4869-8d5f-0b4f3f8360d4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "715c92fa-2470-4869-8d5f-0b4f3f8360d4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "32c72906-a147-498a-a113-be950d59104f", "name": "tr(r:p1rdt8898-p1rdt8898lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d887dbc-43bd-413e-8e72-5c95a2ed0be8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6ff626c-d2fc-4b97-9013-4fd544d946a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6ff626c-d2fc-4b97-9013-4fd544d946a2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "ef3714fd-edab-4865-a2ad-4ee8d9fde607", "name": "tr(r:p1rdt8901-p1rdt8901lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f23ab51c-56f3-4421-b66e-7cdcf109787d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d53c0a2-78cc-4988-85a4-884ef039f5fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d53c0a2-78cc-4988-85a4-884ef039f5fa"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "955c5326-6c66-4d62-bf37-292638de7f37", "name": "tr(r:p1rdt8902-p1rdt8902lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f44ec9b-338a-4ae1-a26b-26422f218c13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d1c8eb9-7f79-49ad-9e93-6c7cdcc95e22"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "1ee50b0d-7af3-4a06-b0ea-4bc31090e03c", "name": "tr(r:p1rdt8904-p1rdt8904lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2edd17c2-6dfb-4f86-8998-b90a99755e96"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e111e213-bcbe-42c4-b6ab-2c734ff5341c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e111e213-bcbe-42c4-b6ab-2c734ff5341c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "90046b1e-ffaf-44e0-87b3-cb95655e8345", "name": "tr(r:p1rdt8905-p1rdt8905lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "924fc042-6ddc-484b-b09f-c65b35817d25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2777cc-f3fd-491f-a10b-4ed381cb948d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2777cc-f3fd-491f-a10b-4ed381cb948d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "eec52181-4f73-420b-8698-07ba3d2a5ba4", "name": "tr(r:p1rdt8911-p1rdt8911lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26613f51-86bf-4ae1-86c0-f23e48cf606e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c306f79a-0240-465e-a486-d0f11614fc57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c306f79a-0240-465e-a486-d0f11614fc57"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "63095410-c01a-4602-bc80-e104ffc07c8f", "name": "tr(r:p1rdt8915-p1rdt8915lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "361385c6-bb6d-4bbc-ab7d-4a5774e03d82"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2fbbca23-6473-4344-ac2e-cc97078b3d8d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2fbbca23-6473-4344-ac2e-cc97078b3d8d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "40e3269c-7a28-4e20-9fa3-df93e3a99468", "name": "tr(r:p1rdt8916-p1rdt8916lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "adcc33f8-72a3-434c-a021-6c5973713a91"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d268e33-708d-4bae-8348-cad27fd0d81a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d268e33-708d-4bae-8348-cad27fd0d81a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "e40cccd7-b398-4341-a909-7d8cef79eb67", "name": "tr(r:p1rdt9075-p1rdt9075lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "907828f5-8e26-41c4-8fbc-a3744608181a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6752e8f4-9e37-476d-aec2-4a2fe7c1e2dc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6752e8f4-9e37-476d-aec2-4a2fe7c1e2dc"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "adc3a07a-82a2-4e00-a6c8-1099bb4e0b40", "name": "tr(r:p1rdt9076-p1rdt9076lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2ce5116-c4f0-4ac7-a34f-3ba44c99d04b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdd64386-e256-47f8-8cef-1c933f993a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdd64386-e256-47f8-8cef-1c933f993a29"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "8f50d2c0-fc10-4b59-b588-c78fee9366a5", "name": "tr(r:p1rdt9077-p1rdt9077lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b7f2f09-976a-45da-8186-229aeedeb689"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b83eaaa-a092-42ca-a746-db4d9658d62b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b83eaaa-a092-42ca-a746-db4d9658d62b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "7ecefea9-516a-4cb1-8c06-cac3a09bcc5e"}}}}, {"uuid": "557e8429-9e93-4160-bcc4-3af879a36ea8", "name": "tr(r:p1rdt9084-p1rdt9084lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4251587d-600f-40a0-9aec-229fb2e3f2df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f0e4f59-8a46-4abf-9f06-e0383a59a45d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f0e4f59-8a46-4abf-9f06-e0383a59a45d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "eec76648-0280-4fe0-af8d-9f996d84c74a", "name": "tr(r:p1rdt9085-p1rdt9085lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7fcdf409-885c-4c95-834e-988842ed3f5c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "565bbfb1-a28f-4db2-be48-cbd58972025a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "565bbfb1-a28f-4db2-be48-cbd58972025a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "b66392de-bea5-4d55-91a6-d82ab4d1b213", "name": "tr(r:p1rdt9089-p1rdt9089lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b4ec275-bea8-45f2-94cb-5e24e82179d8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8108ac8-2807-4a40-85c2-db21efaadadb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8108ac8-2807-4a40-85c2-db21efaadadb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "ed549b0d-f520-47b7-a35d-6cd2a3169d35", "name": "tr(r:p1rdt9090-p1rdt9090lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52c72b52-1c6c-46f6-adbe-1054eb233c20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fc84159-09b1-4ca9-9a7a-a4fecab19f83"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fc84159-09b1-4ca9-9a7a-a4fecab19f83"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "dd3d2dc6-ddf3-4f3b-80f3-cdfaa7eee7d2", "name": "tr(r:p1rdt9091-p1rdt9091lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "563c6bb3-d8ed-4fce-ad66-3892426248df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e93ea18-150d-4d80-bac7-f3e1b87c5b4e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e93ea18-150d-4d80-bac7-f3e1b87c5b4e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "fe126484-9dac-44a4-b9a7-d0b95131a9d9", "name": "tr(r:p1rdt9093-p1rdt9093lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c29179f3-0b4e-449c-8562-a8fcb675be6c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f0726b7-3050-4c78-9c06-b9fd0c863ff3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f0726b7-3050-4c78-9c06-b9fd0c863ff3"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "658d959f-56a4-46f3-9c64-ca76eaf73c1e", "name": "tr(r:p1rdt9264-p1rdt9264lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bdf3994-bb0c-44f4-b1ea-ab29e73bd39c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c01a9b2-b002-4279-905e-950452f64f32"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c01a9b2-b002-4279-905e-950452f64f32"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a17c260a-bae1-4173-8fee-fc9ea0a4b0f0", "name": "tr(r:p1rdt9265-p1rdt9265lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b336e76f-17f3-4f5d-ba84-f24c3a4e3eed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "77d62813-61d3-4afd-9f21-869e2ea23e17"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "77d62813-61d3-4afd-9f21-869e2ea23e17"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "c682f3a2-335b-4876-b3f3-f17e582fb5fb", "name": "tr(r:p1rdt9266-p1rdt9266lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fbb2bd0-d109-4248-85f3-266fe479677f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78278589-be2d-4d99-9c03-92c221348917"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78278589-be2d-4d99-9c03-92c221348917"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4d59ae8b-6777-434b-8467-62a8e2a3f6f4", "name": "tr(r:p1rdt9298-p1rdt9298lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61ba1001-8b9d-481c-b205-45c6e0beadc1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "208f222c-45db-445f-ba0b-a4a195ca68a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "208f222c-45db-445f-ba0b-a4a195ca68a6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "bf58b1a3-eb94-4a84-8bf6-222f3696dfcb", "name": "tr(r:p1rdt9302-p1rdt9302lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4a41fe9-62ce-45ba-abcd-086ba429baa0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180fad26-0e7d-4e2c-ba17-c8e3315ca278"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180fad26-0e7d-4e2c-ba17-c8e3315ca278"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "3276927a-5d0f-4e74-818b-d91b6f65ebdd", "name": "tr(r:p1rdt9310-p1rdt9310lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3035d22c-c39f-4f07-9fe9-29888b16057d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4940a0e-dcc2-45fb-baa9-aadc84f8e882"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4940a0e-dcc2-45fb-baa9-aadc84f8e882"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "daf94052-bd8a-473d-8d00-900a40a66ce6", "name": "tr(r:p1rdt9311-p1rdt9311lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7011f1dc-1e7d-4961-9a23-620b7f5737af"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9e0aa7d-9097-4370-8f5e-52a5885da85c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9e0aa7d-9097-4370-8f5e-52a5885da85c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "31a8d47b-fb37-4710-af26-3c40bd619792", "name": "tr(r:p1rdt9312-p1rdt9312lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8721684-5439-482c-b8e5-be330d3cf745"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a21f5ca-51ef-4f81-8229-163182f011cf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a21f5ca-51ef-4f81-8229-163182f011cf"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b6d6629c-ebae-47e9-826d-42a5addc585d", "name": "tr(r:p1rdt9314-p1rdt9314lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d25f8d60-8aa7-4975-96dc-eba7696fa8ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3df13d91-365e-411b-917d-b28df5989280"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3df13d91-365e-411b-917d-b28df5989280"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "3f1254d8-6ad4-49ed-91f4-40f1125f1d3c", "name": "tr(r:p1rdt9316-p1rdt9316lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "644c5887-31f1-436c-bbf6-dae5a70743a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c97a99f-545b-49cd-b1fe-4fd9e04bf37f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c97a99f-545b-49cd-b1fe-4fd9e04bf37f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "26117ef4-73d0-4826-814c-c5b074c7979d", "name": "tr(r:p1rdt9333-p1rdt9333lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0da91bf8-b687-47df-a7dc-41e6166fd667"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a68a1c01-a04c-4af6-b1c8-02ddd1d67e0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a68a1c01-a04c-4af6-b1c8-02ddd1d67e0b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "a951a707-992b-4291-83f8-194955fad7e9", "name": "tr(r:p1rdt9377-p1rdt9377lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61972a50-ce24-4ec1-8535-402665b55a55"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e98299cb-8bad-49ea-8627-f3cfe01b9e23"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e98299cb-8bad-49ea-8627-f3cfe01b9e23"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9d097eb6-0536-4329-9e47-689931548ec9", "name": "tr(r:p1rdt9381-p1rdt9381lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5791345-57dc-4f54-ab54-ea63e6a54ee0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e37f182-5a60-470d-8f5b-ba145cc27973"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e37f182-5a60-470d-8f5b-ba145cc27973"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "bb2e720c-aead-4e23-990b-b5d38b5fc81c", "name": "tr(r:p1rdt9384-p1rdt9384lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6eb9c7a5-5ab1-4d9b-a59e-538b68ad0bb9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abd09ea6-221c-47d9-beec-1062e0dd4aa7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abd09ea6-221c-47d9-beec-1062e0dd4aa7"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "35b8a83c-ef5a-4306-832c-66fbeafd2d4a", "name": "tr(r:p1rdt9396-p1rdt9396lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a597011-5e60-46fe-90d6-85728ff0ffa3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc7e0a25-d6d6-4b07-b3dc-4fe5646915e2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc7e0a25-d6d6-4b07-b3dc-4fe5646915e2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d3d8a817-bbdd-4e5c-a3e4-0432297353b5", "name": "tr(r:p1rdt9413-p1rdt9413lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f750e531-5ade-40a9-9bb0-042220ce9807"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8180ee90-a46e-4d85-9742-d47b24f5e169"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8180ee90-a46e-4d85-9742-d47b24f5e169"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f57739f9-f91a-47bd-ab2b-41bc22a489c3", "name": "tr(r:p1rdt9463-p1rdt9463lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "271ab023-4425-40d8-8080-2481c71309b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a015abb-ec63-4b31-9314-283b8499646e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a015abb-ec63-4b31-9314-283b8499646e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "85d043cd-32d6-4018-a524-c982b2241a28", "name": "tr(r:p1rdt9468-p1rdt9468lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b5695dd-714e-4de1-a63a-f142ff0460e1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4dbe1628-cd17-4f37-af2b-dd752c290fa4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4dbe1628-cd17-4f37-af2b-dd752c290fa4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "631e9419-1b56-46f4-baa0-837e133891b1", "name": "tr(r:p1rdt9469-p1rdt9469lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3fd32c7-2866-4699-93a8-dd3a9997d349"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09613257-d4cb-4c50-b35a-8aefc637c0c9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09613257-d4cb-4c50-b35a-8aefc637c0c9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "de8ccb6c-d747-4480-b079-fd149cfb48d4", "name": "tr(r:p1rdt9470-p1rdt9470lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acf91e46-ba32-44c3-a829-14c80a693d7d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1ab8727-2758-4513-8a7d-e02381faf1e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1ab8727-2758-4513-8a7d-e02381faf1e4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "abf8851d-3ebe-42f7-aaba-d53fec8ddcfb", "name": "tr(r:p1rdt9473-p1rdt9473lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4d8bafa-711d-4fd7-8374-7eeaeb43edcd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c14c3211-a0d5-464f-820c-cab04764d907"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c14c3211-a0d5-464f-820c-cab04764d907"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4a2ad2ab-089f-4dac-a5a0-897f492a374c", "name": "tr(r:p1rdt9479-p1rdt9479lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b006c3-79f8-4a27-b76a-d1b458ff2a21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6a8f268-6a5a-4b23-bd91-53c6b031442a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6a8f268-6a5a-4b23-bd91-53c6b031442a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1a93d30f-d1a4-4015-8c87-b38dda765cb8", "name": "tr(r:p1rdt16638-p1rdt16638lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c0d417e-c787-4b0a-a39e-b19ef274b36b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac361065-6b3c-4ac6-96d5-9b474eb3b80f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac361065-6b3c-4ac6-96d5-9b474eb3b80f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "25afcea6-d24a-41da-92e4-6285c2cd8d94", "name": "tr(r:p1rdt16725-p1rdt16725lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2d0eb0b-bbb6-4b3e-bdc6-4c8a0e7d466f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bae9a352-584d-4cf0-9ebd-eb280b684e78"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bae9a352-584d-4cf0-9ebd-eb280b684e78"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f5a6c76a-0ecf-4a13-89aa-362ecadefd29", "name": "tr(r:p1rdt28-p1rdt28lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e71eb2d5-cd10-498d-b9eb-ae337b2f8af6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b3c997d-cd47-439c-aeb9-326e12c2b869"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b3c997d-cd47-439c-aeb9-326e12c2b869"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "86f8773c-114a-4b4c-b9e3-f2717953ca11", "name": "tr(r:p1rdt29-p1rdt29lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b238dc5-7d8e-4b2d-8449-4dc212d7d227"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61fc3980-6aa4-415c-91c1-10d32c7c359c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61fc3980-6aa4-415c-91c1-10d32c7c359c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c02272a2-6a29-4dc3-bc03-1478a851798d", "name": "tr(r:p1rdt30-p1rdt30lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fa95a19-0e0a-49b3-bb86-7103fbaa4110"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d2be3b5-dbfc-4099-af9a-96368e60fe23"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d2be3b5-dbfc-4099-af9a-96368e60fe23"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "3426e057-9462-4775-84b0-7991d0317028", "name": "tr(r:p1rdt31-p1rdt31lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7c543753-fa26-41df-b7a6-3664395c0d45"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3510eedd-535c-4e58-b81e-c5ec09030479"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3510eedd-535c-4e58-b81e-c5ec09030479"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "06dad8ed-fa0c-4bfc-835f-beac3577743f", "name": "tr(r:p1rdt32-p1rdt32lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "834e959c-8ee6-4fff-b1fc-54c20fc0f20b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e374d6d6-1e75-4808-b65a-c7033e1bd528"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e374d6d6-1e75-4808-b65a-c7033e1bd528"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4d7dca1d-26ad-41f4-ae1b-09c3150c2ff2", "name": "tr(r:p1rdt33-p1rdt33lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f55e4012-a11d-4883-baac-9c013aff6058"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "065c8583-45e5-466c-b4c0-1c66bf970abe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "065c8583-45e5-466c-b4c0-1c66bf970abe"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "07af1c2e-7068-4f93-89df-8790c6dfe1c5", "name": "tr(r:p1rdt34-p1rdt34lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a9c4411-f402-464c-ad25-d439b87ef768"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "553a6868-acec-4492-a52d-5aa08414c612"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "553a6868-acec-4492-a52d-5aa08414c612"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "045e1e63-2c81-46df-aaf1-4d47299340da", "name": "tr(r:p1rdt35-p1rdt35lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "edc22f66-e919-448e-b990-76033c281d43"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f98cc066-fca3-4489-9770-047caee3e742"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f98cc066-fca3-4489-9770-047caee3e742"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "686d21ca-2738-4df6-85e2-c888af76c985", "name": "tr(r:p1rdt36-p1rdt36lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8dcdfef-b40e-4f1c-9b7c-e84846f68c5a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a4fb658-c3ba-428a-82bf-b38ae68dd908"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a4fb658-c3ba-428a-82bf-b38ae68dd908"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c5b237cb-07a9-4965-9cd9-3e14350dcdea", "name": "tr(r:p1rdt37-p1rdt37lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dcbfdc3-b597-4e9e-a86f-4d0ff396ba70"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90a16370-67f7-4abd-992c-990d1eb8f17e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90a16370-67f7-4abd-992c-990d1eb8f17e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "da3f8abb-ffb8-4aea-ab9c-4af9437c8824", "name": "tr(r:p1rdt38-p1rdt38lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b45513a3-8e88-45e9-99d3-6d244c90c256"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "752aca33-7682-4e8c-a8b1-624467e02958"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "752aca33-7682-4e8c-a8b1-624467e02958"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f893bdea-9004-4473-94ab-1c3988f9d1b5", "name": "tr(r:p1rdt39-p1rdt39lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a01c83d1-4adb-4b2a-8de3-441d7c1dd054"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "623ec6b4-cb70-4437-9d79-5ec577bc3199"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "623ec6b4-cb70-4437-9d79-5ec577bc3199"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a4e4a009-9d22-4aa9-9fcc-1b5aa8981612", "name": "tr(r:p1rdt40-p1rdt40lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "577124ac-ea2b-4a60-be47-14b0f5db305e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d08444c-79a3-4ba0-8c69-1855a600dea0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d08444c-79a3-4ba0-8c69-1855a600dea0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1fc2c7da-303e-48e2-b221-3ef3ba1d67ec", "name": "tr(r:p1rdt41-p1rdt41lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5b5b3ae-f657-4fd4-a311-ab1dbe9d749e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "793d0bf4-4d9f-4df4-bc95-d528dd7d31d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "793d0bf4-4d9f-4df4-bc95-d528dd7d31d5"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "80968e2c-9233-46d1-bc47-325532bf9287", "name": "tr(r:p1rdt42-p1rdt42lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a778171c-22a1-4320-9e3c-43888d734e34"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8fb27dc9-b404-49d1-84dd-0cde418b037d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8fb27dc9-b404-49d1-84dd-0cde418b037d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "68f7ceff-6b60-422e-bd73-d4d1a0f6e584", "name": "tr(r:p1rdt43-p1rdt43lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7728581d-66fc-4e7e-b2b0-85fa02c90523"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "274aa0ec-f229-454c-b52d-23130bacb97e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "274aa0ec-f229-454c-b52d-23130bacb97e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "8a76055a-3d2f-4462-98c5-e1f8ff4d0cb5", "name": "tr(r:p1rdt44-p1rdt44lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d9ee2ff-e2bc-4d76-b173-5ba5cc48c9b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c813f8a2-226b-431d-a41a-195cf5e8b01a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c813f8a2-226b-431d-a41a-195cf5e8b01a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "16131cf6-271d-4626-98a8-fbae6ee38baf", "name": "tr(r:p1rdt45-p1rdt45lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29a79372-9c75-4a9c-81df-a7491b87e58a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e276abc-bb27-47e4-9de8-adaccbf964dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e276abc-bb27-47e4-9de8-adaccbf964dd"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "76a4d98e-68c5-49bf-910b-f3f35032d52f", "name": "tr(r:p1rdt46-p1rdt46lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05082892-d69e-4c8f-ba19-c2a627e1c345"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aacdcb46-43e3-4147-ac25-3a9c1223e13a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aacdcb46-43e3-4147-ac25-3a9c1223e13a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f0cbaba9-64ec-4d25-8744-ef1281846908", "name": "tr(r:p1rdt47-p1rdt47lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ea0531d-530c-4088-86a1-3de96a8938ea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f031530a-b3fc-4f8e-b0ac-139009d1256c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f031530a-b3fc-4f8e-b0ac-139009d1256c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b0be705e-8c18-4891-b919-bb25a7238d83", "name": "tr(r:p1rdt48-p1rdt48lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1667a8c6-aeb4-4f22-97b8-62ffefcc12a4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f1790fe-a399-46e3-b9e3-5979837777ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f1790fe-a399-46e3-b9e3-5979837777ce"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b0e0d3ff-8ba6-472a-a5eb-d28c6ce44f6c", "name": "tr(r:p1rdt49-p1rdt49lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "137c345c-77cc-4324-bc0e-e0ba896a5f43"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e5bcc7e-f35c-4bbf-a7ff-a82817488b11"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e5bcc7e-f35c-4bbf-a7ff-a82817488b11"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "26b88ccb-02b0-4122-b422-897c4c26a389", "name": "tr(r:p1rdt50-p1rdt50lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c5d8237-0351-4eb2-83e6-13975b37bfa7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8208c617-caa9-46a5-b28a-8a5b0d9898a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8208c617-caa9-46a5-b28a-8a5b0d9898a2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "cc35b6a6-16d4-488e-97ec-7b14db0fa4c0", "name": "tr(r:p1rdt51-p1rdt51lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f5cef5c-bcaf-4cd9-afbb-a18bd14dfcd4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09d7f030-a9b4-4705-82af-6cf140ba64d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09d7f030-a9b4-4705-82af-6cf140ba64d1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "0e0c6d92-cc6e-448f-a29c-1e3178238ad3", "name": "tr(r:p1rdt52-p1rdt52lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6fb1323-f697-4423-a70d-838056200402"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c70a7331-8c41-4370-b053-3eae432d52ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c70a7331-8c41-4370-b053-3eae432d52ae"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "5050b907-1a62-46d6-82b0-89342148ec87", "name": "tr(r:p1rdt53-p1rdt53lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7305e2b-0a48-4630-8b8e-c3819f1c9cd1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2536a0eb-a35c-40d4-9773-b78379e7481a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2536a0eb-a35c-40d4-9773-b78379e7481a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "28ce3059-1ead-42c2-bdee-4daff71b5662", "name": "tr(r:p1rdt54-p1rdt54lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a898f4c-f522-4e69-be4a-e935e339e011"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57889d14-4aac-4aee-a9e2-677a047e8054"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57889d14-4aac-4aee-a9e2-677a047e8054"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a7a2f704-cd96-459a-b12e-4435494a6582", "name": "tr(r:p1rdt56-p1rdt56lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1d8f5898-7d36-4e40-9980-76d11ef18adb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85ad3bf0-7e82-4e32-8106-faddcf725bdf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85ad3bf0-7e82-4e32-8106-faddcf725bdf"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "0c05cc28-0486-48b9-95ba-0b91bb9b6203", "name": "tr(r:p1rdt58-p1rdt58lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a4ccf80-2611-4089-9353-439809aa7854"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3367c40-9f47-42d9-b627-bc502b170f2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3367c40-9f47-42d9-b627-bc502b170f2a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ffc7aa30-29d5-4db5-aab5-dd84d3d0772b", "name": "tr(r:p1rdt59-p1rdt59lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ea7e0bb-bdc5-429a-8889-2f12c94db72e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8aca9934-9439-4ce6-9ee3-475980324054"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8aca9934-9439-4ce6-9ee3-475980324054"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1696924f-e157-42db-86ef-900c1b1cf8bb", "name": "tr(r:p1rdt60-p1rdt60lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d99e903-3536-4a73-b0d5-ca11f5af6e32"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2517cea-05d3-4b7f-b9fc-0df0fde81235"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2517cea-05d3-4b7f-b9fc-0df0fde81235"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "89ed6c2c-a1ba-4a20-8835-2c08c61547b5", "name": "tr(r:p1rdt61-p1rdt61lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "744725a8-af2a-47cf-948f-9d453a932e32"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70f11a44-826f-45b8-9dc3-0f51ce6c9733"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70f11a44-826f-45b8-9dc3-0f51ce6c9733"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "08edc741-554e-4ef1-bd93-218dc727e5ef", "name": "tr(r:p1rdt63-p1rdt63lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab2b6727-4d87-4b00-bd49-ba7a6b1b9ce6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fac6d4e1-b14d-4973-9626-6a4bde2d2a42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fac6d4e1-b14d-4973-9626-6a4bde2d2a42"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "5ad5756b-21d2-45ca-a385-c7e2b2f1bb99", "name": "tr(r:p1rdt65-p1rdt65lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9397c58-45a1-4ec3-bd84-b4cd5b52dc80"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ae9cb89-7cb8-48c6-a5bc-4178ee364ae8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ae9cb89-7cb8-48c6-a5bc-4178ee364ae8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "72eed041-134e-4a31-a0d0-02a861b323f4", "name": "tr(r:p1rdt66-p1rdt66lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99615f32-0614-4c23-a1e1-b3e8e5688cce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfb9fa3b-c758-4c2e-bc51-f297b1ed21bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfb9fa3b-c758-4c2e-bc51-f297b1ed21bf"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f8d59a4d-dfb6-49b3-83c6-0454d6bfd414", "name": "tr(r:p1rdt68-p1rdt68lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb9e5f0f-8bcf-4019-a786-3f24334e9ae7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd2d6296-a302-4027-9e5f-c24a56a1a1ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd2d6296-a302-4027-9e5f-c24a56a1a1ac"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "5e8def15-b1ef-4d36-afe9-0db73af1d8f4", "name": "tr(r:p1rdt69-p1rdt69lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9396562e-4f87-4e04-b248-502b851fe19e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7057debb-bd4d-4156-a253-0f3a14cdd784"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7057debb-bd4d-4156-a253-0f3a14cdd784"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "00e0932e-3680-4ecb-a35f-b8f379416748", "name": "tr(r:p1rdt70-p1rdt70lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50f3b5f3-3fb5-4fb9-b2e6-b37200af0901"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02440066-bc62-4629-96c5-4b497827de5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02440066-bc62-4629-96c5-4b497827de5b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "aec13c01-30e8-4332-b54a-8dac2e56eb19", "name": "tr(r:p1rdt71-p1rdt71lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bcea1fd6-3c51-48af-8528-d3d7bc8e4f01"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e71f106d-4b41-405f-bce9-3d06b336a554"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e71f106d-4b41-405f-bce9-3d06b336a554"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1f2db932-2776-43d2-b812-944ba379f05d", "name": "tr(r:p1rdt72-p1rdt72lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2faff95d-f394-427a-9d62-75224f830c9e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b59eeab-d997-4186-ab59-0424644d5aeb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b59eeab-d997-4186-ab59-0424644d5aeb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a54d9c9c-facb-438a-9923-8a3535cb078c", "name": "tr(r:p1rdt73-p1rdt73lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc531967-1a7b-4424-83ee-e1131c6fd94c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f027d15-df82-4989-93e5-a3b40c862b08"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f027d15-df82-4989-93e5-a3b40c862b08"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "e5380797-1d80-4e0a-945e-4762a3c8c342", "name": "tr(r:p1rdt74-p1rdt74lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b884fef-8b8f-4ed5-9033-b8177d1c7d70"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37880102-8a9c-4f7b-930a-b29a94241866"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37880102-8a9c-4f7b-930a-b29a94241866"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ea369155-ad0d-4a7c-a74b-c12c8e2ecdea", "name": "tr(r:p1rdt75-p1rdt75lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "510ea93c-7dd1-4fa3-ba3f-6c362856c7c1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "699bbf24-59ba-4dba-8bd4-1cf04a7e6e47"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "699bbf24-59ba-4dba-8bd4-1cf04a7e6e47"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "147887b1-2e3e-4a7e-b06c-a473fb5f6bab", "name": "tr(r:p1rdt76-p1rdt76lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfbb212a-9882-4468-86ac-578c93fde1d8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ecf2223-f120-45b4-8aab-a36d60161aec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ecf2223-f120-45b4-8aab-a36d60161aec"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "86c622f6-2403-4cab-95f8-aff9389bf18a", "name": "tr(r:p1rdt77-p1rdt77lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31b06630-2aae-4fe7-9e31-f911c91121cd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3fd9bf7-ecdd-4dcb-966a-f426d5f2ee81"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3fd9bf7-ecdd-4dcb-966a-f426d5f2ee81"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4a5f4547-b555-41df-9f08-d6c0903360f2", "name": "tr(r:p1rdt78-p1rdt78lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36bfd1f1-80ca-4b7d-a68b-9aa77ceff96e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f0255b7-5369-40eb-8814-959b0d4245b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f0255b7-5369-40eb-8814-959b0d4245b6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ecc7b1e7-8a00-4c32-93e5-f1f981ed361a", "name": "tr(r:p1rdt79-p1rdt79lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b32c9763-ddff-435b-a28c-8f65111c6cb2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "624d03d5-ac53-4d58-ac86-62834fa13c61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "624d03d5-ac53-4d58-ac86-62834fa13c61"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "da68cb40-2f31-4750-a2b6-b091f4654833", "name": "tr(r:p1rdt80-p1rdt80lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b03f8e29-a5b2-4bed-b68c-219276674b6a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ce05c72-facf-447f-ba14-cc2ef64579a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ce05c72-facf-447f-ba14-cc2ef64579a8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "87aeed9d-f5cd-4e6f-810f-c6099cb337fb", "name": "tr(r:p1rdt81-p1rdt81lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "063e25be-2abb-49ae-b459-ddd08ba93bb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b610625-09e3-4b72-a8fe-b0c36f5e137c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b610625-09e3-4b72-a8fe-b0c36f5e137c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "83fcf4f2-0d36-4f7a-b36f-b4151a82bc3c", "name": "tr(r:p1rdt82-p1rdt82lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7627cbc6-c54a-432b-8cba-59e448f6d45a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9872669f-fd85-458a-8951-ec12965fb42b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9872669f-fd85-458a-8951-ec12965fb42b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a617b3b6-59a8-4e36-a4ea-11874a9cd427", "name": "tr(r:p1rdt83-p1rdt83lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aa0b7c2-9d55-4faf-8778-76a6f23bcf3e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8dac1e07-5eb6-4945-a3d9-95b77310358d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8dac1e07-5eb6-4945-a3d9-95b77310358d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d41dfd2f-d99a-4bd0-910f-036f4aebe455", "name": "tr(r:p1rdt84-p1rdt84lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e9f4b13-5fb5-46b2-9258-83582d47d61a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdb8aaf1-0e21-42e0-a72d-666646561235"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdb8aaf1-0e21-42e0-a72d-666646561235"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "26f6d003-75a7-4f8c-b229-262ff28235a3", "name": "tr(r:p1rdt85-p1rdt85lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fc415bc-f457-4e9f-bbd4-783a71b67ad6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40f4034e-c735-419b-80cd-d729d75f4692"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40f4034e-c735-419b-80cd-d729d75f4692"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "110f66e7-2818-450b-a67e-5acde54125dc", "name": "tr(r:p1rdt89-p1rdt89lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac4ad276-90cb-48c0-bfd0-1f2aa0233ce2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "468963dd-428d-4810-a28c-1904bc06fa64", "name": "tr(r:p1rdt150-p1rdt150lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12451cbc-eb14-4814-b274-12eb2241c78a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d156fdde-5620-4a6f-b8c1-a3ab986fcc88"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d156fdde-5620-4a6f-b8c1-a3ab986fcc88"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "4ffdedbd-6f86-4c39-ba6a-51dbb16741b8", "name": "tr(r:p1rdt177-p1rdt177lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ad84ef4-4dcc-42f7-99ed-b8d21cebc465"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d64d858-a9f7-430f-890e-a456f8913c30"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d64d858-a9f7-430f-890e-a456f8913c30"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6d4ef4b9-6445-45ff-9620-36a122a1de83", "name": "tr(r:p1rdt178-p1rdt178lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6912a245-ac1c-4ddd-b021-3bc35cbbe2c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3314fa8-a838-4028-abb5-043425fd0785"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3314fa8-a838-4028-abb5-043425fd0785"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "38f32bd3-69bf-4ea6-b2fd-ec94b21cce20", "name": "tr(r:p1rdt180-p1rdt180lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5258d4de-be4c-478d-b752-7f4efb0af0a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3e633bc-311e-4698-a413-9c6cf09c42a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3e633bc-311e-4698-a413-9c6cf09c42a8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "16bc9340-852f-45b4-8c50-5aafae060aaf", "name": "tr(r:p1rdt181-p1rdt181lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79d0fee6-369b-4f95-a2d2-cd05232652e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05401825-91f8-41f8-9204-ab5806458594"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05401825-91f8-41f8-9204-ab5806458594"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "fd2bbd2d-e55a-4574-9301-aa415ede0134", "name": "tr(r:p1rdt182-p1rdt182lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08e378d4-4ca6-4c9e-93fa-36ff87a3cf0f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db407ddd-fb81-4767-99e1-9aeab12fc770"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db407ddd-fb81-4767-99e1-9aeab12fc770"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "8cfbd069-d0c7-45ae-a317-62a2b705c48e", "name": "tr(r:p1rdt209-p1rdt209lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcb27aab-e828-41a6-ad98-d197897a1a69"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4724ea16-dc31-48f8-98b8-b9a223e9a4bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4724ea16-dc31-48f8-98b8-b9a223e9a4bb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "12ffe536-6060-4f3e-907b-af4d833feb8b", "name": "tr(r:p1rdt210-p1rdt210lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d782d5e-3960-415c-9e33-6742777a5a0a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05f6a3bf-d465-4f16-8205-616d1f4dd465"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05f6a3bf-d465-4f16-8205-616d1f4dd465"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "938e5105-62c4-4dab-b455-5ac4f54fcb4d", "name": "tr(r:p1rdt211-p1rdt211lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9401940-26a4-40f3-9b9a-5231a5c4e171"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1d5af6ce-9a4c-414a-bbd8-15d82f50cb57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1d5af6ce-9a4c-414a-bbd8-15d82f50cb57"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "91a80b45-db0d-4e91-b5a9-5fb6548e00dc", "name": "tr(r:p1rdt233-p1rdt233lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f5ed5d5-93fc-4f3c-a78b-df7019863b67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "591461d4-20da-4165-a210-4dbaedd81016"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "591461d4-20da-4165-a210-4dbaedd81016"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "228841e9-58e9-49e3-804f-445cc0619ab5", "name": "tr(r:p1rdt234-p1rdt234lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80331f15-8b31-454c-a289-49cb79923252"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e480f304-b192-4107-91e1-131d481657b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e480f304-b192-4107-91e1-131d481657b2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "40659e90-bb60-4c4f-a678-ce45935e490f", "name": "tr(r:p1rdt235-p1rdt235lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14b85850-d83e-4a5e-83c3-ccb485bb85aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d8a6708a-d098-4e02-aac6-4aba7fdc71a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d8a6708a-d098-4e02-aac6-4aba7fdc71a5"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a5c0e877-4159-4080-9098-05bf7f634c74", "name": "tr(r:p1rdt236-p1rdt236lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "190d6c51-94b6-462e-8fee-cce57f1ab66d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7dd709e3-c5ec-4a01-8297-11f4d1261c3a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7dd709e3-c5ec-4a01-8297-11f4d1261c3a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "7769b43e-a233-4400-b584-7a9f35d5a83e", "name": "tr(r:p1rdt237-p1rdt237lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8c8b8f8-7a41-4d16-b509-2d7c7af9509d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b72726f3-250c-4d98-86bc-5120137bd0f1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b72726f3-250c-4d98-86bc-5120137bd0f1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "7d4d8011-cd32-41e0-bdbf-c7f5d31224e2", "name": "tr(r:p1rdt251-p1rdt251lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b801037a-e1bb-4c5c-8d18-ed285c8c1d3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42dff28c-89e7-4b56-bf23-3dcdd3ca216f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42dff28c-89e7-4b56-bf23-3dcdd3ca216f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "0f9e6d0b-d35a-481b-b931-182fab18aed5", "name": "tr(r:p1rdt252-p1rdt252lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69b2ee46-ab5f-48c8-a26b-170ed2b57fcb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5fd6466-e740-4f06-a842-798195d62154"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "72716a86-0835-4f9b-8e47-9a6051a19336", "name": "tr(r:p1rdt253-p1rdt253lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1a85646-be2b-4b15-9c2f-cc603c7e06df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "704fece3-3b83-4c0b-bcd1-d463b3cdaf6b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "704fece3-3b83-4c0b-bcd1-d463b3cdaf6b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d1c72dc1-3fc7-4da6-9a5d-72909f222914", "name": "tr(r:p1rdt254-p1rdt254lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ab802e3-3a0a-413c-8865-e3b3d08e44a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "655d8f44-aa2f-4548-a1ca-83fcce9fa7aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "655d8f44-aa2f-4548-a1ca-83fcce9fa7aa"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "bf18b63e-79ca-428f-a8b3-d5a935d41cbd", "name": "tr(r:p1rdt257-p1rdt257lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fb307f7-3690-4931-999a-4daab4d8c9e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4c28500-44f7-47c6-b8a8-d1e3468494e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4c28500-44f7-47c6-b8a8-d1e3468494e3"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "96da8edc-0a10-48ed-bb7d-3658fda97e9f", "name": "tr(r:p1rdt258-p1rdt258lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e28087b-b80e-4043-b0f0-0bc82c91f5e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad9ffaef-f21b-43da-9f67-3a8271edb6bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad9ffaef-f21b-43da-9f67-3a8271edb6bd"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c3a4c349-43bd-4f33-98fa-ccf7e44ca6f5", "name": "tr(r:p1rdt259-p1rdt259lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33a0a070-9cce-4a82-bd22-24a65f02ef97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6a0feb3-78c1-4d69-8d18-2a8c3abdcf54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6a0feb3-78c1-4d69-8d18-2a8c3abdcf54"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ecbce8a2-3f89-4fa2-a55a-3bd07a3ac13f", "name": "tr(r:p1rdt260-p1rdt260lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba0ef4a3-43ba-469b-8ce8-ca7a5a984071"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d8d796d8-6750-4ca5-ae07-1b07331ce6ee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d8d796d8-6750-4ca5-ae07-1b07331ce6ee"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6d2548c2-862a-4a2f-b2c3-1d8870d42a76", "name": "tr(r:p1rdt261-p1rdt261lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "209cebda-044a-42a3-b2f0-fe5b76b80643"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fe4ec5b6-61fb-4b66-9e43-19d81af88966"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fe4ec5b6-61fb-4b66-9e43-19d81af88966"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4bd983f3-706d-4920-a462-e4bf12558318", "name": "tr(r:p1rdt262-p1rdt262lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf660777-f77e-4d9b-afff-73a84274c270"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30952601-1479-4770-9b77-9fe3465310b7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30952601-1479-4770-9b77-9fe3465310b7"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "034163b4-1e88-4baa-a811-5fbd58057562", "name": "tr(r:p1rdt263-p1rdt263lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e26e5dc-8c98-4fcd-b125-3265eb00f3f2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c7501f4-0394-4766-a3c5-b17fda7f3817"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c7501f4-0394-4766-a3c5-b17fda7f3817"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "559841a4-f8e4-4cdd-b1c6-04b11c6d09dc", "name": "tr(r:p1rdt270-p1rdt270lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7eca59ac-01f1-40d7-a0ec-51f355285e01"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d33a03d6-fddc-4e47-8018-cd7d290b30b0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d33a03d6-fddc-4e47-8018-cd7d290b30b0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c6c81cef-c3ee-431b-a3ab-6ad7205c02a8", "name": "tr(r:p1rdt275-p1rdt275lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d4e6a87-0313-419f-8feb-7ea3a29f59ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6715c6a-6869-412a-8e59-e5c2eb03c56b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6715c6a-6869-412a-8e59-e5c2eb03c56b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6bb22125-784e-40ef-bbc5-22745e6216db", "name": "tr(r:p1rdt276-p1rdt276lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "186ffdfe-2346-4218-bd6b-b813ea6b3b62"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b478b4f8-8d5e-47b0-a56a-8b991dc8d944"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b478b4f8-8d5e-47b0-a56a-8b991dc8d944"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ae187547-57ce-46fc-9314-8dda6c95cd4f", "name": "tr(r:p1rdt277-p1rdt277lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "add5e39f-f02e-4a61-a156-d5721cec25d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24486e15-ff1e-45b3-aa02-703263f04844"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24486e15-ff1e-45b3-aa02-703263f04844"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4676c5fd-19ba-4329-a862-9e9801bd00a8", "name": "tr(r:p1rdt278-p1rdt278lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b89bfea1-97cd-41f7-af59-9602a3fc6c06"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8af5824-d5d7-4cba-98b7-d72993909f22"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8af5824-d5d7-4cba-98b7-d72993909f22"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d0bfd334-fcc6-47b4-bfc1-72eb7bb1598c", "name": "tr(r:p1rdt279-p1rdt279lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "153bb615-5ee5-4eec-bcf7-94ea0098aeb6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bf679fe-712f-4db6-9df9-debb29b7ee73"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bf679fe-712f-4db6-9df9-debb29b7ee73"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "da111543-380a-4eb1-88b8-031590d01eda", "name": "tr(r:p1rdt280-p1rdt280lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9cb7919-b8bd-46c1-a173-90a5d241c46e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e4eafd2-0f68-4e2a-a62c-89cb877004d4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e4eafd2-0f68-4e2a-a62c-89cb877004d4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "655bfadd-98d9-4039-821c-21dbe9549447", "name": "tr(r:p1rdt281-p1rdt281lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac745c6f-6e78-4a68-affa-649f91d3aa7c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e01a56d-1bfc-4169-9c3e-1373f9dbeb38"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e01a56d-1bfc-4169-9c3e-1373f9dbeb38"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "015e49ce-e6a5-4944-aaf3-b61823a75f58", "name": "tr(r:p1rdt297-p1rdt297lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d32493ec-06be-48ef-959e-779c79c507a3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a8430e1-656f-4fe2-a11b-00adf429d75d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a8430e1-656f-4fe2-a11b-00adf429d75d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d68d8140-dff3-41be-a497-53455f71c1f6", "name": "tr(r:p1rdt298-p1rdt298lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a468f13-c61f-4c01-aa27-c75fb02030e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33e93250-9c11-4650-9469-412129855857"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33e93250-9c11-4650-9469-412129855857"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b887118e-e038-4a64-9fa7-6038d52ec663", "name": "tr(r:p1rdt303-p1rdt303lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9672c49b-8316-4907-b204-7505483210b0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6353ab92-f66f-47d8-97ac-058cf030ff82"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6353ab92-f66f-47d8-97ac-058cf030ff82"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "5d8d8e70-8ce0-42db-a87f-175f615651be", "name": "tr(r:p1rdt304-p1rdt304lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c51ccb17-eed6-4ce0-b839-e7b26001fe3e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a22ac71-bf3a-4016-86ce-fb25f471be5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a22ac71-bf3a-4016-86ce-fb25f471be5b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "0f017bf0-d183-4c7b-80ed-7c974ee6f0bd", "name": "tr(r:p1rdt305-p1rdt305lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b936973-54dc-41e7-a413-8932c31f0793"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90948977-fe1a-43b3-a8a4-86c080ae4906"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90948977-fe1a-43b3-a8a4-86c080ae4906"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "d74936db-efae-41d6-84f2-34c53eef6e48", "name": "tr(r:p1rdt306-p1rdt306lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57a78c71-e5a8-4dfd-8359-e368b7b198fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53eba878-66fa-4d30-8af4-1f583abe5f16"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53eba878-66fa-4d30-8af4-1f583abe5f16"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b13ff87f-aca0-42a0-a97e-45cfc6179f01", "name": "tr(r:p1rdt335-p1rdt335lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b07c4a6-39a7-4521-bce7-3f1ca0ff4a66"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8e448ea-e66d-4e16-80c0-8e742d7cac55"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8e448ea-e66d-4e16-80c0-8e742d7cac55"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1b3a45a4-d129-4c3f-8eb1-9066ad24ac9c", "name": "tr(r:p1rdt374-p1rdt374lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d425a00d-c0e9-465d-9d9b-af4d64708fba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35993388-185f-4d1d-9dcb-16eb7556728f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35993388-185f-4d1d-9dcb-16eb7556728f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "0c577442-ca1d-4668-b313-e9fbb1e29ad8", "name": "tr(r:p1rdt376-p1rdt376lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f2a0358-b10d-4b62-8f8d-9a5054fae87d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d354e81e-b007-4bbe-b1db-50d7afacd0e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d354e81e-b007-4bbe-b1db-50d7afacd0e0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "de6b39ba-8c53-4f20-8506-bd2983c7866c", "name": "tr(r:p1rdt383-p1rdt383lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d49257c8-f8eb-4024-9c02-461d18cdd3d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8569c197-174f-46ef-96c2-e0c674d7b046"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8569c197-174f-46ef-96c2-e0c674d7b046"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b775f5a3-abc7-439d-8cc2-1dfdb80e9ee2", "name": "tr(r:p1rdt384-p1rdt384lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7adf2f4b-f0fd-4c53-abcf-d90fe1a2b4c4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c56b4839-f007-4c9b-93a7-9147399f983f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c56b4839-f007-4c9b-93a7-9147399f983f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "dfb875e0-909c-48e0-a0f3-c240ef90cdec", "name": "tr(r:p1rdt385-p1rdt385lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91f76b91-e00a-4a88-8ee8-ec403c2c7d96"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "579c3e97-d1dc-4306-91e6-4cbbed29f882"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "579c3e97-d1dc-4306-91e6-4cbbed29f882"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "fb2a2471-54f3-48e3-9ee1-13f4e72e499a", "name": "tr(r:p1rdt414-p1rdt414lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3034e62-dd19-4ecb-bb39-6d0566e3a2ef"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29a78735-964b-4381-bea0-01e5b1b79be9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29a78735-964b-4381-bea0-01e5b1b79be9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "860da100-ad3e-4792-8a28-931f8187fdf3", "name": "tr(r:p1rdt415-p1rdt415lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "101c6236-a474-45c8-b065-f5fa045b1107"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "789d55de-619d-43cd-b056-ebe1be4c2dea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "789d55de-619d-43cd-b056-ebe1be4c2dea"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "feeba731-1ea5-4dc1-9a62-c0e1d7795eea", "name": "tr(r:p1rdt416-p1rdt416lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d16d5f5e-a376-4e39-a845-d2cde8800da3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473f5822-3412-4f3d-836e-f62314efa5b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473f5822-3412-4f3d-836e-f62314efa5b2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "47414dae-3422-48b1-bdca-7b83009a888f", "name": "tr(r:p1rdt417-p1rdt417lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "71fa675e-bc20-46f7-b6f1-c88962f9f3cb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98bb09be-6506-49e8-8fd8-1a01d6861162"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98bb09be-6506-49e8-8fd8-1a01d6861162"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b0547079-9b1b-44dc-ab7c-c29dfea00990", "name": "tr(r:p1rdt418-p1rdt418lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16b7f1e9-3405-4c5f-96c7-d5c08d791907"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e189aaf-7650-49b4-83dd-94a29111aca2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e189aaf-7650-49b4-83dd-94a29111aca2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "469de0ef-7a25-4acd-9205-a71329a39894", "name": "tr(r:p1rdt419-p1rdt419lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81cfd2a2-295c-4b73-abba-05ffee810523"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d9603d6-5e5e-4cc0-aa86-1bdb80f7e1cf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d9603d6-5e5e-4cc0-aa86-1bdb80f7e1cf"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "47093818-356c-43f7-a773-06ced59d5483", "name": "tr(r:p1rdt420-p1rdt420lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4cf05060-0a39-49a9-a761-79fb136e2965"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51673983-9230-421b-8501-bf71601b1b13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51673983-9230-421b-8501-bf71601b1b13"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d972da8f-8281-4cb3-ba18-4eb86c2e9897", "name": "tr(r:p1rdt438-p1rdt438lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10620dcc-049c-4417-b4ac-922a56c0d4a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41f19802-32ca-4afc-8418-fe93e3ced1bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41f19802-32ca-4afc-8418-fe93e3ced1bb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1e703d7c-207c-41bd-8432-62623e3294cd", "name": "tr(r:p1rdt445-p1rdt445lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11571d26-573f-49f7-99fd-828dde97afd8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc7e7e51-f849-4bf4-b720-462daeb21932"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc7e7e51-f849-4bf4-b720-462daeb21932"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4ef117e0-3533-4ed5-a707-27b8b79018e0", "name": "tr(r:p1rdt446-p1rdt446lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3dfe357-889d-42e0-a59a-821c9f843456"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0727e1f5-f2ca-4e19-9dc3-89e185002e52"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0727e1f5-f2ca-4e19-9dc3-89e185002e52"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "31791e27-69b5-46d6-8de1-580b87fb30a0", "name": "tr(r:p1rdt452-p1rdt452lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d51e6f65-c45c-4f10-a17f-6ef684a0a06c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44f86829-17fc-4e83-b2a5-705454293161"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44f86829-17fc-4e83-b2a5-705454293161"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "dea578b9-0003-4140-837c-70a58205dfbf", "name": "tr(r:p1rdt453-p1rdt453lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1bb6f93-7aed-47d7-99db-7c17352a42b8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d58e1471-844f-46ef-9d9a-43753b1dee25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d58e1471-844f-46ef-9d9a-43753b1dee25"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "de71a091-0216-4333-98f4-8e2ee12f7aa3", "name": "tr(r:p1rdt454-p1rdt454lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "82459f47-0c6f-4173-8c35-5a9fe5db9713"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b3e7941-9bdd-48f9-a4a5-a553da9bbb57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b3e7941-9bdd-48f9-a4a5-a553da9bbb57"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "7146b2ad-9e2f-4f11-a4a5-d9ea6e8d1f02", "name": "tr(r:p1rdt455-p1rdt455lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "183de04a-a665-4112-a912-1df68b61d164"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53b40b3c-db5a-4fa0-bedb-f293c6eac473"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53b40b3c-db5a-4fa0-bedb-f293c6eac473"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c7fedd72-fdc1-4ce2-9c76-ae0aa80d0095", "name": "tr(r:p1rdt456-p1rdt456lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf205ba7-ac66-4318-aeca-c75eb96cbd1e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6abe982-a205-4607-bacf-08e9d7cb6f54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6abe982-a205-4607-bacf-08e9d7cb6f54"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "780c1284-1c66-4d72-92d1-cf26850a20c2", "name": "tr(r:p1rdt457-p1rdt457lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12fef7fc-57f0-4494-becd-4724b84dbbcb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "866745cc-62c9-429f-8389-fcc5a1710f17"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "866745cc-62c9-429f-8389-fcc5a1710f17"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "226ddf12-0560-4cd0-a652-b078040e8853", "name": "tr(r:p1rdt458-p1rdt458lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b61caefd-d5aa-4019-9ac0-aaf8cedc71d0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67e071ab-e3dc-4779-9e81-585547cd22ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67e071ab-e3dc-4779-9e81-585547cd22ca"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "50a65c14-ae69-47d6-ae06-21a2674632d0", "name": "tr(r:p1rdt459-p1rdt459lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12d5c579-0570-44db-a751-8eeb92355af9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9eb57d99-ae80-43da-b0cb-b26bdd583e1a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9eb57d99-ae80-43da-b0cb-b26bdd583e1a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "93fa4f7d-bc58-4a12-a440-e0c490ea7b13", "name": "tr(r:p1rdt460-p1rdt460lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59b616e5-76b8-406c-843f-5c71398af81b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028bc055-0ee6-4729-8cd2-15bd7153f975"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028bc055-0ee6-4729-8cd2-15bd7153f975"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "1f7a885d-21ca-439d-8116-826789387357", "name": "tr(r:p1rdt461-p1rdt461lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc35f44e-d8d9-41d0-b014-caa3d8d7a91e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd9a4931-435b-4b48-907c-024c0b8a4816"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd9a4931-435b-4b48-907c-024c0b8a4816"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f12f78be-1ac8-4e86-98fe-de6b0683fa21", "name": "tr(r:p1rdt462-p1rdt462lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fcfdc5bf-1c87-42e2-8b35-1f7125d3b5ed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d96f458-607c-4820-90b1-6fb2625ace7f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d96f458-607c-4820-90b1-6fb2625ace7f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "b7ade355-2af9-4a38-a2d7-80f3335d2f0c", "name": "tr(r:p1rdt463-p1rdt463lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7637cfdb-6a14-4313-95d4-e25beba178f3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f660c35e-85f8-4f0e-b03b-806006c76c67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f660c35e-85f8-4f0e-b03b-806006c76c67"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6148cbd4-2f8c-491c-9c54-ff853b4687d9", "name": "tr(r:p1rdt464-p1rdt464lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a634585d-0c70-428e-a3b2-1ec4717d7878"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "749e07aa-74ce-40f2-a352-9c55f9914377"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "749e07aa-74ce-40f2-a352-9c55f9914377"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "70d8c332-07fd-46c0-a5a7-a6324f5ec5bb", "name": "tr(r:p1rdt465-p1rdt465lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a94f7afe-e8b0-4b24-8196-6b05e98c3830"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "433b0872-49c4-452c-941c-8083a72840ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "433b0872-49c4-452c-941c-8083a72840ce"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "780d3254-dfcd-415b-afdf-f9fdb2cce1dd", "name": "tr(r:p1rdt466-p1rdt466lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b20fa59a-8573-461a-9c4a-0d47e40d2601"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f422478c-0d77-48c8-87fb-e883d945f8a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f422478c-0d77-48c8-87fb-e883d945f8a6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "31fd8d26-743e-4351-a4ae-a932c424b517", "name": "tr(r:p1rdt467-p1rdt467lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ae86125-88c3-44fb-9fe9-1a5d820606f6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23ed76af-dcb2-4333-ae4c-d7439a37cf87"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23ed76af-dcb2-4333-ae4c-d7439a37cf87"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4b987818-3fb4-41f5-b55b-d2cfb74befcd", "name": "tr(r:p1rdt468-p1rdt468lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a180b972-cf0e-4a2e-9bcf-a0ad90bb3d83"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b368fb8f-7f4d-4558-b6b2-2e1db4087727"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b368fb8f-7f4d-4558-b6b2-2e1db4087727"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "18968b56-3a29-41e6-8cbd-8e4fe75001da", "name": "tr(r:p1rdt469-p1rdt469lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48179f57-b0b9-491b-b654-81583768923a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d12ab15f-746d-462b-b395-e2b330ba1226"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d12ab15f-746d-462b-b395-e2b330ba1226"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "bac74da6-006a-4067-88ac-cf7b2ae508c5", "name": "tr(r:p1rdt470-p1rdt470lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86178159-ccd7-45a3-b711-ac237321d52a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15ab2647-a801-4cb5-a1f7-528118ff5dea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15ab2647-a801-4cb5-a1f7-528118ff5dea"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "58fdf097-af18-4b81-9503-d9f13735bc26", "name": "tr(r:p1rdt471-p1rdt471lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eed7e6a8-2b4a-4a54-b69a-e3e1a0614213"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40d98c0b-4c66-4581-9553-f5f57c4b27b9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40d98c0b-4c66-4581-9553-f5f57c4b27b9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "346f5458-a006-49fe-9e5e-9c356990a6a0", "name": "tr(r:p1rdt472-p1rdt472lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fa14b51-a977-4e40-8f9c-28249e576fcf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f026a1d3-23b0-4454-a09b-e1c08cc06392"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f026a1d3-23b0-4454-a09b-e1c08cc06392"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b8909095-2209-43a8-8464-b209838a828c", "name": "tr(r:p1rdt473-p1rdt473lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76880999-6f79-4fc6-9367-1c419eee26d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f435ec5-8c03-45ba-925b-83bad9501047"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f435ec5-8c03-45ba-925b-83bad9501047"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "dc6f4797-c71e-4d15-b933-feb4df8752ec", "name": "tr(r:p1rdt474-p1rdt474lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d709af4b-1115-403b-a68d-76c63c93adf2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "839858f4-3b18-40c3-86f3-e27225e6aba4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "839858f4-3b18-40c3-86f3-e27225e6aba4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "7ecefea9-516a-4cb1-8c06-cac3a09bcc5e"}}}}, {"uuid": "a492d8ab-a787-43c8-8be0-cab66a7fe3ed", "name": "tr(r:p1rdt475-p1rdt475lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c39140c6-8892-480a-81b9-738c67ed1591"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1be3e20a-3890-4e9c-b568-ca99421e751c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1be3e20a-3890-4e9c-b568-ca99421e751c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6c7260e3-92c6-44cf-9183-fc804409b3d6", "name": "tr(r:p1rdt476-p1rdt476lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5421facb-0713-404c-97e9-56669fc762b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ffde8c6-9dba-4f13-bda5-a0edf17c736d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ffde8c6-9dba-4f13-bda5-a0edf17c736d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "d82f544d-1e58-46b4-9ecf-d4338fbccc82", "name": "tr(r:p1rdt477-p1rdt477lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d1eb09d-dff4-4fa3-b96f-ef59b63d6128"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7c94703b-303a-4713-95c0-b2933fe0e70b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7c94703b-303a-4713-95c0-b2933fe0e70b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d4ce0825-6ee4-4ec0-b8e1-1563e762a41a", "name": "tr(r:p1rdt478-p1rdt478lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eba354c-f4bf-4c49-a8ad-998ab9489e5a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c93c776d-68b8-4e4e-8e5e-d5e34003473c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c93c776d-68b8-4e4e-8e5e-d5e34003473c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "50c07068-48a1-4f26-a8f9-e98aa62f0fdd", "name": "tr(r:p1rdt479-p1rdt479lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85acd1fb-6da3-432a-9508-855ca991641b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8037b713-d948-43c9-8370-fb8fcf6dec15"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8037b713-d948-43c9-8370-fb8fcf6dec15"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d06c50e8-54b3-4baf-9665-3fab274a9a46", "name": "tr(r:p1rdt480-p1rdt480lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e5c3d02-1cd2-45e4-90d3-10b135c65f13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "423402f9-4160-481b-9951-a955f8314075"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "423402f9-4160-481b-9951-a955f8314075"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "733cc0fd-6a39-4cd5-981f-4aa1b1b62549", "name": "tr(r:p1rdt481-p1rdt481lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cf3136f-6dbe-4ed7-b9cb-e9f73b191f76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1761b021-00e0-4880-9f05-62cf67aef0e6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1761b021-00e0-4880-9f05-62cf67aef0e6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "148864d6-cab0-456d-8328-a75ad9b03ce3", "name": "tr(r:p1rdt482-p1rdt482lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10c2463d-8563-4737-aa7d-e1195c0af9f6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c445ea76-5167-4d55-b0c5-cc53dadc5b5e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c445ea76-5167-4d55-b0c5-cc53dadc5b5e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "16ca4d3d-9bed-4e6b-9ece-eb18548033ae", "name": "tr(r:p1rdt483-p1rdt483lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69b5d686-dae0-44c5-a261-f1a73bcb168e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "475b6a50-9814-4016-bb88-be5b1b2ac31d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "475b6a50-9814-4016-bb88-be5b1b2ac31d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "ab0dffc8-6dfa-406d-b78d-386b299b2e2a", "name": "tr(r:p1rdt484-p1rdt484lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b57b8e2b-62c2-49a0-801d-02cab8092ebd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f396745a-5edb-4ab8-8bc7-2b181719cbf4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f396745a-5edb-4ab8-8bc7-2b181719cbf4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "2bc14fe0-06d7-4d06-b082-4fa14b69d913", "name": "tr(r:p1rdt485-p1rdt485lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "445f61a4-8045-4558-a3c1-bb44336737ec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da38ec0a-f37d-4a5c-8da0-93410a8fb475"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da38ec0a-f37d-4a5c-8da0-93410a8fb475"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "181d142b-a1d2-40c7-919b-2bfaf1cb98b1", "name": "tr(r:p1rdt486-p1rdt486lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd2f4b00-6e8b-4faa-a760-7c28f8d36a36"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5401d366-a5a2-4753-82b7-ce4fa08a1227"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5401d366-a5a2-4753-82b7-ce4fa08a1227"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "e13b87a6-1453-493b-90f8-63417bffadc3", "name": "tr(r:p1rdt487-p1rdt487lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfb0d992-ab18-4f73-933e-a01ce73ef3b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47fbd02f-6c12-4bd6-9d6d-2e0cddbfcd88"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47fbd02f-6c12-4bd6-9d6d-2e0cddbfcd88"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "bea3ce73-1bb4-443c-82bc-d9633e9913c4", "name": "tr(r:p1rdt488-p1rdt488lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fa474a3-1d6b-454b-9170-6a8d13789c43"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e517b810-e6b9-4c89-b47d-1921fcf88edc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e517b810-e6b9-4c89-b47d-1921fcf88edc"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d221e7c0-5e3a-459f-9f2a-d00e62491d88", "name": "tr(r:p1rdt489-p1rdt489lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cee642e7-12f0-4746-841e-d8cda6fff57e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25637062-8ca3-4694-a27b-7be93e89fe1f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25637062-8ca3-4694-a27b-7be93e89fe1f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "948d2dba-9df5-4bb4-af04-fb9494f3d65b", "name": "tr(r:p1rdt3776-p1rdt3776lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "170a2bcb-d7ce-4617-855b-9111b84262ed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ae14df0-ab3b-47ba-9f83-c09f03999c76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ae14df0-ab3b-47ba-9f83-c09f03999c76"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "bea0945a-b96b-4d1e-af74-0291cbd1a874", "name": "tr(r:p1rdt3777-p1rdt3777lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f9af980-79c4-4daf-b8fc-44e02953f98b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4662f3f5-e75b-4b75-a6d6-7ada745d5cca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4662f3f5-e75b-4b75-a6d6-7ada745d5cca"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1c340bc5-1d86-44e6-860a-aa40bf29d777", "name": "tr(r:p1rdt5098-p1rdt5098lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9100fbd6-863e-48b2-94ed-aca1ef0947bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e734d7a2-9161-41c0-ba78-9f9f87120acd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e734d7a2-9161-41c0-ba78-9f9f87120acd"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "7f4eefd7-8cd4-4fbc-b0c6-c16c3485fc58", "name": "tr(r:p1rdt5548-p1rdt5548lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bf1b63d-fbce-42f8-9948-2e09bfa67409"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91754be7-2a91-4a0e-9856-43d08ecc7c70"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91754be7-2a91-4a0e-9856-43d08ecc7c70"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "9ccccbb6-1805-4071-91ed-04ab43c1c51c", "name": "tr(r:p1rdt5551-p1rdt5551lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f7fed4f-197e-4a79-97e5-df595377736b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9dec144-ef2e-44fe-990a-c9d70b740410"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "c1bbd3f0-4b5f-4f5e-9f82-e2b15dd3929a", "name": "tr(r:p1rdt5557-p1rdt5557lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cca8918c-30e6-4619-a5e0-8c0d3451f9c4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05b867e6-2f18-49e7-9869-55bd5048c201"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05b867e6-2f18-49e7-9869-55bd5048c201"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "28066d5a-8a37-45e6-9713-935dbb6c1a49", "name": "tr(r:p1rdt5560-p1rdt5560lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68117bef-16c5-40c9-9356-76ef5c056650"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5838960-8556-4e4a-95e9-8ba9ffc85141"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5838960-8556-4e4a-95e9-8ba9ffc85141"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "16844ce2-d0e7-4577-8d19-df2522470625", "name": "tr(r:p1rdt5561-p1rdt5561lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "756f6cd8-301b-4fac-b414-d72853616c6e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "133a0221-0cd5-46d2-af84-e80e7951c96d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "133a0221-0cd5-46d2-af84-e80e7951c96d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "eab10644-9384-4c94-aa36-fb0daba50b19", "name": "tr(r:p1rdt5563-p1rdt5563lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad24f98d-f022-4e62-b80b-426052810759"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a150dd3-61a4-4df9-90e2-6c72f80af819"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "9a8345b1-a786-435c-b6a2-aa53580a9679", "name": "tr(r:p1rdt5564-p1rdt5564lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8444c9ea-ff7a-4b0a-9ea6-9c18770565cb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8deb73b9-51fc-447d-9da7-14a6dccff646"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8deb73b9-51fc-447d-9da7-14a6dccff646"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "3e20fcc3-e522-405e-b12e-8621cb7b680c", "name": "tr(r:p1rdt5565-p1rdt5565lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5e479d3-aae0-47b8-b707-bad1191df1e7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60dc1291-a843-4abf-bfc6-ff8afc8c0b98"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "ec61176f-dfbb-4efa-9041-5ed2ff4bf1e3", "name": "tr(r:p1rdt5566-p1rdt5566lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fed9557-b170-4817-8bd8-efc3b9f7c982"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95a5450a-6630-41b8-863f-0c1f3fcfa7ab"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95a5450a-6630-41b8-863f-0c1f3fcfa7ab"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "947b40bb-4805-40ad-a01b-6cf8e7426679", "name": "tr(r:p1rdt5568-p1rdt5568lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c83b6ee-20fc-4ca0-a778-44735283afd5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "613d178b-a566-408d-bad0-e4a170eea971"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "613d178b-a566-408d-bad0-e4a170eea971"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "64da0817-f4a8-4b5f-821e-148131beb92e", "name": "tr(r:p1rdt5574-p1rdt5574lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9906676-e9b9-4d51-b1c2-a6b6fe187faa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "248e065d-80ed-4926-9625-295c83da6b61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "248e065d-80ed-4926-9625-295c83da6b61"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "999c9328-68fe-4d34-86d9-ce9c7fb60c2f", "name": "tr(r:p1rdt5577-p1rdt5577lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1c8b424-4509-4fd2-93e2-4fd54f6cf49a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21ef4ae6-b80e-49f1-8d00-1cb6e27bc8f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21ef4ae6-b80e-49f1-8d00-1cb6e27bc8f9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "e453767e-243b-4848-8e6f-d4589c09194a", "name": "tr(r:p1rdt6261-p1rdt6261lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53e5fee4-5a31-448e-8bd0-d8996468d085"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9859b30-0238-493e-be1a-cb6717413ba9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9859b30-0238-493e-be1a-cb6717413ba9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d1f70d0a-2390-439b-9b24-5f2fd1ba1b0e", "name": "tr(r:p1rdt6262-p1rdt6262lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf092ec9-ecda-4216-9ac0-0bc035973515"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2172b57-622b-44c1-8388-f1e2b1def312"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2172b57-622b-44c1-8388-f1e2b1def312"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4c14ecdf-6121-49db-8273-ea7012401a9f", "name": "tr(r:p1rdt6263-p1rdt6263lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c61df077-693e-4e67-aea6-ee60b99406d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4717b000-fd39-4647-9fbd-5152323dacee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4717b000-fd39-4647-9fbd-5152323dacee"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f6f3fa51-a1a9-40ca-a3b6-7a6ccdb26701", "name": "tr(r:p1rdt6264-p1rdt6264lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a03d20d-664a-4e80-abec-a36910787829"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e916c16-525d-4092-b627-ad44b4bf4ee8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e916c16-525d-4092-b627-ad44b4bf4ee8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "836aa093-a7b6-4940-8c75-2a7058b9fd71", "name": "tr(r:p1rdt6265-p1rdt6265lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d316c13-77c1-4412-baf9-801f7e5ae407"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6bb5544-e583-4ded-9a10-23be70f5598e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6bb5544-e583-4ded-9a10-23be70f5598e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a7f86fff-0adf-4b9e-a9b6-97e3117ec95b", "name": "tr(r:p1rdt6266-p1rdt6266lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e22d08f0-2afc-426a-a0c0-6b00cc1103aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8af5f9d5-965c-4a0c-a811-67d3bed744ee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8af5f9d5-965c-4a0c-a811-67d3bed744ee"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "30021e75-15ad-4990-ba5f-192e884daaac", "name": "tr(r:p1rdt6267-p1rdt6267lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a1d9cfa7-0024-4896-a263-2715086f2ad6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0ddd898-3193-4bff-80f4-fd4a7eae9aec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0ddd898-3193-4bff-80f4-fd4a7eae9aec"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "5db55ec0-9b26-43e1-82d6-1c6f792b80a2", "name": "tr(r:p1rdt6488-p1rdt6488lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63b2f1e6-5e15-4433-85ee-ff7bb7218b96"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1155c2c-544c-45f4-969f-b3ec4f6773bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1155c2c-544c-45f4-969f-b3ec4f6773bb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "cca02abb-5240-4ef2-a315-f28e00a41488", "name": "tr(r:p1rdt6578-p1rdt6578lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e257530-1fe2-410b-83a1-57789e6ddeda"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "555453a3-3fb7-426a-bbd2-9e588d4bd01d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "555453a3-3fb7-426a-bbd2-9e588d4bd01d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "82e64de1-effc-4dc0-8ddc-bb009d05dc60", "name": "tr(r:p1rdt6580-p1rdt6580lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68298e92-fca3-44e9-9271-f79be47c9c63"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5de250a8-ecca-4ab4-9f09-685aaf92d13d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5de250a8-ecca-4ab4-9f09-685aaf92d13d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "405b2028-87da-44cf-b232-708b560b6d4b", "name": "tr(r:p1rdt6584-p1rdt6584lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9f273a36-c30d-4962-81f4-26f8d20e1cf4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d944119-3782-49dd-8b24-1f68d8ee687c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d944119-3782-49dd-8b24-1f68d8ee687c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "c275a539-c206-4c1b-b36e-ae22a3bf13dc", "name": "tr(r:p1rdt6587-p1rdt6587lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d77add8e-ba22-4b44-9c0b-0bddc251a573"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c587698-7940-4edb-9105-f31f1304f7e9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c587698-7940-4edb-9105-f31f1304f7e9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "8aca787a-f329-4a51-90aa-09e490eaa499", "name": "tr(r:p1rdt6588-p1rdt6588lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1648fe3-a7f9-47aa-b168-d2b56cf220e7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61045f72-ca3d-4e0d-ac3d-db5fbf099b38"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61045f72-ca3d-4e0d-ac3d-db5fbf099b38"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "95128a03-d470-48ae-9a19-83abda77d90b", "name": "tr(r:p1rdt6590-p1rdt6590lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5291ea2b-6990-407b-b8d4-d6868bf37310"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a289017a-8ab9-4412-857a-694b3aa2c63d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a289017a-8ab9-4412-857a-694b3aa2c63d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "0672aaa6-8f76-454c-95bd-e281f1293e08", "name": "tr(r:p1rdt6591-p1rdt6591lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1d0a85a-62dc-46d2-bae1-d43d07743a34"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a7c2e99-857f-4119-be4a-daaca586f056"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a7c2e99-857f-4119-be4a-daaca586f056"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "43ad826f-468f-4f62-98d4-419243839bab", "name": "tr(r:p1rdt7286-p1rdt7286lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02351140-e632-49e2-83e4-7e5bc1c8856a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ad975da-cce7-49cb-be78-20c4abf8975e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ad975da-cce7-49cb-be78-20c4abf8975e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b64f19d8-c621-4f06-afaa-159a18f970d5", "name": "tr(r:p1rdt7289-p1rdt7289lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f8375b7-7bdd-409c-9fa1-5c13bd233364"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56d21681-3c57-4575-af17-f2bbf9874a10"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56d21681-3c57-4575-af17-f2bbf9874a10"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f9343681-c623-4b98-830a-4a29714dd9c3", "name": "tr(r:p1rdt7293-p1rdt7293lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4afa9bec-d8da-4449-ab96-9f875bae3c33"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9b0c16f-f433-4aa1-8d00-dc1573dfb5e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9b0c16f-f433-4aa1-8d00-dc1573dfb5e3"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "60823e00-c5b4-4bc4-b042-fad0c40a99f2", "name": "tr(r:p1rdt7294-p1rdt7294lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a955da2d-e212-4026-b1fb-0021a04ded07"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67d2b31-f05a-4160-83ae-55154224a9ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67d2b31-f05a-4160-83ae-55154224a9ca"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "74ab20a7-57a7-4622-ae93-7d3d717abc43", "name": "tr(r:p1rdt7299-p1rdt7299lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d065da7b-7e88-4e63-a47c-959f4d4c6e1c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4cee417a-3410-4907-8621-f0d3fcbc047c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4cee417a-3410-4907-8621-f0d3fcbc047c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "169914f1-885b-4f8c-8e51-c5f5b78521a8", "name": "tr(r:p1rdt7300-p1rdt7300lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05f14a3e-053e-4b65-b962-da7804b9e2c1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "135a6a49-6562-4c6e-a41f-f5f78c0ac3e6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "135a6a49-6562-4c6e-a41f-f5f78c0ac3e6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "de07b9e3-46b7-43d8-be06-8daf46d20cfd", "name": "tr(r:p1rdt7303-p1rdt7303lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6f24e3a-088a-4d1b-8292-03015289d88e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7cbc8145-b198-46f1-a3fd-55a05637e618"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7cbc8145-b198-46f1-a3fd-55a05637e618"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c7531bac-a558-4fc5-abb3-cad5e268ecb0", "name": "tr(r:p1rdt7308-p1rdt7308lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2e605b4-fe7a-4571-947d-8ae19de627d8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5094655-6494-44a9-b0ff-c5b418dcc11e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5094655-6494-44a9-b0ff-c5b418dcc11e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "3d21883c-9d1b-4ac2-882a-5f72cfb7a512", "name": "tr(r:p1rdt7316-p1rdt7316lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6322bf4d-0976-4bae-94c0-f76f83ccb9bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a289e26d-2d86-4fdf-942b-881b91ca18eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a289e26d-2d86-4fdf-942b-881b91ca18eb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c412fc0f-8313-41e6-84c6-5d4022182b14", "name": "tr(r:p1rdt7317-p1rdt7317lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48efebbb-c70a-47d3-aae3-0e39088fc455"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16c465cf-c4ae-4702-ba6c-0b7704eda764"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16c465cf-c4ae-4702-ba6c-0b7704eda764"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "fa23fabe-02fd-4549-80aa-192a59aeac79", "name": "tr(r:p1rdt7321-p1rdt7321lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b468be25-1324-46ab-9424-887741ca1134"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c855f7bb-1f33-4c3e-9deb-e3f9c5aba07d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c855f7bb-1f33-4c3e-9deb-e3f9c5aba07d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "94144af1-4cd0-49b9-aa6a-bb93661492f8", "name": "tr(r:p1rdt7737-p1rdt7737lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d2ea25e-3d48-4b1d-9e52-768752de2e09"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35be767a-53a1-4fe1-b320-9542dd859d97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35be767a-53a1-4fe1-b320-9542dd859d97"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "53d064dd-1417-4642-8abf-df6fd0b5bb7b", "name": "tr(r:p1rdt7753-p1rdt7753lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d142315b-a247-4a4d-a178-73e3c150a188"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7482f0c-eb85-4e30-a09a-eb9f15bbc22b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7482f0c-eb85-4e30-a09a-eb9f15bbc22b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "05232de7-0f14-4d8a-8559-1177a07f9e5e", "name": "tr(r:p1rdt7757-p1rdt7757lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "081feb5c-d5d5-405e-85d4-f1dd0916fc3d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d343e634-0936-4f21-9e2c-079e19f0dfa1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d343e634-0936-4f21-9e2c-079e19f0dfa1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "51d1c01e-6f22-46ea-8d46-dd93a1b50d2e", "name": "tr(r:p1rdt7791-p1rdt7791lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4413ca7f-fdd1-484e-a0ba-3ff2447ebfef"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28e5f84f-2fac-4b5c-a669-b16988e4d6ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28e5f84f-2fac-4b5c-a669-b16988e4d6ae"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "eb25695e-13e8-42e0-a678-e5405a877c1f", "name": "tr(r:p1rdt7795-p1rdt7795lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bee93ff6-6ff8-4572-b339-c8e897dac81b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3959f944-18f5-4daa-a454-3c6bfb7158ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3959f944-18f5-4daa-a454-3c6bfb7158ff"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b2fecd2c-00e0-43d7-9dc2-60a9fddea649", "name": "tr(r:p1rdt8105-p1rdt8105lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3f91816-7c3f-4fc7-98a5-6dee55e52e9f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b2ec0ba-a854-4631-b97a-4674123d6fe6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b2ec0ba-a854-4631-b97a-4674123d6fe6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1b65440f-5d1e-4c19-b277-993ab8fb0f7b", "name": "tr(r:p1rdt8111-p1rdt8111lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2c69fef-4afb-4bb3-9828-096b812de54a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b639e55-2e33-4582-bb96-06a9d33a3419"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b639e55-2e33-4582-bb96-06a9d33a3419"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "8183c724-3202-4128-b82b-1bc73f3b6420", "name": "tr(r:p1rdt8138-p1rdt8138lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17b633c6-214d-4428-bded-df737f50ffb6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dca9b40e-ed8a-4f75-a703-91539f6c3075"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dca9b40e-ed8a-4f75-a703-91539f6c3075"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "be148e43-4847-4b1e-a963-f6389733140c", "name": "tr(r:p1rdt8146-p1rdt8146lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc34073b-94f6-4c75-8144-8f624bac9cc7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2bee3961-990e-47ac-b49b-d305f8fe0af8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2bee3961-990e-47ac-b49b-d305f8fe0af8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "dddabe2e-2289-4b4b-a2fc-1b5d8b82f030", "name": "tr(r:p1rdt8167-p1rdt8167lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eb3d4eb-71fc-46f3-b588-d223568c411c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "07bd9128-3c6c-4b6e-a209-1ac8b348eaa9", "name": "tr(r:p1rdt8169-p1rdt8169lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6bdb2cf-9373-4d56-a5f9-cb8fa9c67e55"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6349165a-d47a-4cf4-84f9-df5c5f3a0e98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6349165a-d47a-4cf4-84f9-df5c5f3a0e98"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "3205df5e-6618-4256-9cfd-c5dc7b254caa", "name": "tr(r:p1rdt8174-p1rdt8174lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b0f9433-e0a3-458a-8687-c9cf38d0bbb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4903e82a-8cfb-406e-b4bf-5e01068419a3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4903e82a-8cfb-406e-b4bf-5e01068419a3"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "ae939404-c5bd-43ff-931a-6c0769508bc9", "name": "tr(r:p1rdt8180-p1rdt8180lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c93a476-4ad5-41cd-a07b-e2ccc9ef2c3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8e03b63-853e-4cfe-bf4a-3779b2026637"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8e03b63-853e-4cfe-bf4a-3779b2026637"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "63f53b80-31a5-4067-85a7-637448289748", "name": "tr(r:p1rdt8195-p1rdt8195lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8997dae6-8970-4762-98e9-0617375633d6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "782d6008-7fec-46b6-9461-9e33b79539d3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "782d6008-7fec-46b6-9461-9e33b79539d3"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "ce4d8ec3-56e8-4acc-b3b0-dad1fdf76ef5", "name": "tr(r:p1rdt8201-p1rdt8201lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e3d41a7-06a4-460b-aa6c-3a60c8d2de10"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76e33e4f-05be-44d1-a503-fed82b4da974"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76e33e4f-05be-44d1-a503-fed82b4da974"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "4edc8596-210a-4531-a238-d6738acb9e34", "name": "tr(r:p1rdt9055-p1rdt9055lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "246ad62e-5a10-4031-94e7-1732f58f1da9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c1f6cd8-cde1-45cc-87ca-1355efa38077"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c1f6cd8-cde1-45cc-87ca-1355efa38077"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d20d0070-3f40-4462-90d1-9e42dd91adc4", "name": "tr(r:p1rdt9086-p1rdt9086lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75ee3b24-7407-45ba-94d5-abe187306f13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "afb4c195-8bb6-47d5-88f3-76adb9cda250"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "afb4c195-8bb6-47d5-88f3-76adb9cda250"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "766f3347-7aa4-4383-9703-9c0be50e9d7a", "name": "tr(r:p1rdt16394-p1rdt16394lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5b51836-1807-4fab-b877-94a62021569f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40b03cbe-470d-493a-854a-900557ac20c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40b03cbe-470d-493a-854a-900557ac20c8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "40c5e673-05ab-4012-9c8c-7bf871603311", "name": "tr(r:p1rdt16404-p1rdt16404lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61d5dee2-30f8-434d-8c03-76bccff72549"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38b0bd7c-0898-497f-bb24-4add0fd92932"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38b0bd7c-0898-497f-bb24-4add0fd92932"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "e4a24b59-1b02-49fe-8ef5-030327f3023e", "name": "tr(r:p1rdt16424-p1rdt16424lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "18e3da78-83fc-4b8e-9d45-41adb9b753ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23775c66-0b90-443d-8566-491405876e9d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23775c66-0b90-443d-8566-491405876e9d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "484f938d-d59b-4115-9cb2-2685a7b7a2cd", "name": "tr(r:p1rdt16427-p1rdt16427lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d50d3e76-470b-47c2-ada2-da944962b322"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "980376ed-54fd-434c-b58e-0bbd6eaa9954"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "980376ed-54fd-434c-b58e-0bbd6eaa9954"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "449a26bb-c9e0-421e-b94b-a44f94290b59", "name": "tr(r:p1rdt16603-p1rdt16603lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5a9e0f5-d824-4a76-a4f0-88aab072280e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26bc650a-6838-4320-8afa-b8d2f22e96e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26bc650a-6838-4320-8afa-b8d2f22e96e8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "793b342a-db39-473d-bd79-9522eb670aa7", "name": "tr(r:p1rdt16604-p1rdt16604lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98a946e8-3c8a-49ec-be8a-5610c7fc596c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d31da07-e20a-4fb8-95f4-d91450395471"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d31da07-e20a-4fb8-95f4-d91450395471"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4f26c64f-b8eb-4b58-bb0c-13d80ceb0d14", "name": "tr(r:p1rdt16787-p1rdt16787lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4bc644c-9875-4846-8b0f-dfa0568de623"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4a3b828-bddf-4314-b9a5-03b9dfcd2618"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4a3b828-bddf-4314-b9a5-03b9dfcd2618"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "76b84fae-6335-4869-b08d-8984583dd282", "name": "tr(r:p1rdt16790-p1rdt16790lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4774ed1a-85ec-4ca0-8e9a-3b232588fb0c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c261090-bc22-4d81-9a9e-75227cd7c99e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c261090-bc22-4d81-9a9e-75227cd7c99e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "857e2066-6f60-4b44-8d3c-02354b5fd872", "name": "tr(r:p1rdt16847-p1rdt16847lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e35a4f7-19c1-4f59-9adc-b267f6088264"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1abef1d-4ffc-4696-91ca-e81ac36cce61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1abef1d-4ffc-4696-91ca-e81ac36cce61"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "383a2c28-1707-4345-a2fd-dd5fc492cc54", "name": "tr(r:p1rdt16911-p1rdt16911lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "725fbd98-74ba-4143-8947-da9fdc209889"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0df1550a-7e69-42e9-8059-3a36ecb3d253"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0df1550a-7e69-42e9-8059-3a36ecb3d253"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a2ab4202-af90-45ce-b38a-724c78d23cda", "name": "tr(r:p1rdt7711-p1rdt7711lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2131350-dc34-4d8d-8c9f-c29e25bc654c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64b60527-0853-4973-8d7a-78ba5e377799"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "d0a1b468-f2c0-460e-b454-e11535f6f969", "name": "tr(r:p1rdt8473-p1rdt8473lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3a83211-0829-4e2c-b618-3f1fcaba3e87"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "439728c5-fee5-4dfa-9894-261ba6c40e95"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "6ebf15d5-5f87-45c8-b7ce-35edd541c885", "name": "tr(r:p1rdt6028-p1rdt6028lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e39cb1db-d6a6-4b6c-bc73-920e0c34c292"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35f6f747-811d-4fe2-a9c7-991248572c74"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "df70495a-02d7-450a-9a65-9e0b6b42b83f", "name": "tr(r:p1rdt9478-p1rdt9478lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c49b6e87-5834-4e7e-a64c-b4ec0f7d4995"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddf38626-1223-429f-a903-98f1c975020b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "c3da3337-5527-44f4-b208-3bbfe346a0fe", "name": "tr(r:p1rdt6232-p1rdt6232lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b59ad93a-cca2-4a77-8515-a645ddd2a320"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e2630e1-a215-4740-9327-fa004e89863d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "68bf215e-2a75-42a5-be1c-54396a95a2cf", "name": "tr(r:p1rdt8493-p1rdt8493lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfb41891-7063-44b8-9286-1fe763e49924"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c330731a-fd2c-40c7-8fce-94f7e17cf6d9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "21c9d6f7-778e-45ae-9eee-c04828838596", "name": "tr(r:p1rdt93-p1rdt93lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "900d49ce-4834-4f99-8d74-a5e9d2f63ea0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0921e58d-1ada-4556-8b01-8f22d3bf4ee2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0921e58d-1ada-4556-8b01-8f22d3bf4ee2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "4987fad3-04f3-4a44-9e95-4c76bb8da481", "name": "tr(r:p1rdt99-p1rdt99lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "092a9d51-a39c-4c05-905e-93fb1ae96ba2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef6be92d-5d1b-40e2-a2c2-9d0c1f0bf596"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef6be92d-5d1b-40e2-a2c2-9d0c1f0bf596"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "66884d82-d8ad-43ea-b952-5bef9472cc31", "name": "tr(r:p1rdt101-p1rdt101lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d8e5d83-cd9c-4527-9eef-6219c98dfe93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1277a701-9fbd-4853-a809-962475e016c4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1277a701-9fbd-4853-a809-962475e016c4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "b91fce2e-6543-43ed-b024-f99717df76a9", "name": "tr(r:p1rdt108-p1rdt108lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e61ce952-a643-45aa-a466-8aa15ecceb48"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3aa8d6f2-8d84-42d6-8e7b-89e3b1efa03c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3aa8d6f2-8d84-42d6-8e7b-89e3b1efa03c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "d4442785-5a57-40fb-9428-4491355af6e1", "name": "tr(r:p1rdt6121-p1rdt6121lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2390c014-d418-4d63-8438-529a036487db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "448cc5e0-391f-4a6b-8199-25cef4593edf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "448cc5e0-391f-4a6b-8199-25cef4593edf"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "59985662-1964-4761-9713-7d3f9e638929", "name": "tr(r:p1rdt6123-p1rdt6123lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17f807ba-6ad6-4fd9-9dd0-2c0bacea5b24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e81ba94-5857-42e4-aeee-58542cef0fb6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e81ba94-5857-42e4-aeee-58542cef0fb6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "afa627b8-bda7-4883-9053-6fe4ad39ebd2", "name": "tr(r:p1rdt8017-p1rdt8017lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6378abd-969e-4ec8-93eb-2cc39cdb18eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8428de0e-4b06-4f19-bffb-5fed32f96f67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8428de0e-4b06-4f19-bffb-5fed32f96f67"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "101e3b64-572d-4af1-b520-d6b982c7e99e", "name": "tr(r:p1rdt8043-p1rdt8043lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "691c1909-3b71-4e07-abf0-95aaabfa23bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a367e687-b29a-44b4-a943-7b94762e549e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a367e687-b29a-44b4-a943-7b94762e549e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b52a1ec1-eb6d-4410-9a09-fb90b84cc806", "name": "tr(r:p1rdt8065-p1rdt8065lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "862f3566-9443-4b82-8f05-c994581e131a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8bb025c5-31eb-4771-b433-e1dcad03b3ed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8bb025c5-31eb-4771-b433-e1dcad03b3ed"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ac790f59-9dc9-42c3-b7b0-7e682faa07f7", "name": "tr(r:p1rdt8068-p1rdt8068lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f5fbb8b-0c32-4aa7-acaf-7ea2b5e56505"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd01eed6-0e70-42e7-ac29-4bfd2f70366a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd01eed6-0e70-42e7-ac29-4bfd2f70366a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a999665e-c3af-4abd-a73a-56e5afe42a96", "name": "tr(r:p1rdt8070-p1rdt8070lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473520c7-0098-4bc2-a46f-07efd6c3759c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0bcd460-ccf2-42ee-83c6-bada397ab4d6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0bcd460-ccf2-42ee-83c6-bada397ab4d6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "ff4316bf-2fdf-402e-933a-1d92eec8d30e", "name": "tr(r:p1rdt8190-p1rdt8190lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a761aef-a766-40e2-b8d7-e5a918cece18"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f21f4e99-8877-4bb0-9956-9240bc6db3d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f21f4e99-8877-4bb0-9956-9240bc6db3d1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1fa55d6c-fec8-4ebc-baad-a862692ee4e1", "name": "tr(r:p1rdt8204-p1rdt8204lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa2342e6-2d40-424a-830c-a84af4632b6e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d12bf6fb-8dac-4729-bcda-1ee61c63f6e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d12bf6fb-8dac-4729-bcda-1ee61c63f6e8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "029066e1-edb3-4a44-997d-76fbe7264dd0", "name": "tr(r:p1rdt8208-p1rdt8208lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e2b4d77-2388-4897-86fe-06409fa9d222"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ecf11723-eb6d-423c-ac0c-85fa2d1ba846"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ecf11723-eb6d-423c-ac0c-85fa2d1ba846"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6a8d6f6f-b19a-43dc-a86f-18dfc67b7451", "name": "tr(r:p1rdt8578-p1rdt8578lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb866499-9e9c-4394-bd76-d4320ba4934b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1a593e3-4735-47d2-b893-dd2d07c3c47c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1a593e3-4735-47d2-b893-dd2d07c3c47c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1a547192-d0a9-4174-8c47-f8a34d6a8321", "name": "tr(r:p1rdt8583-p1rdt8583lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dbb79e10-21ba-4f04-b8a3-0cf711d26d40"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "134bac3d-5b7e-48d7-950e-01e5b7d43852"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "134bac3d-5b7e-48d7-950e-01e5b7d43852"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d5409af6-e60a-4f61-af90-35c4c7a32310", "name": "tr(r:p1rdt8584-p1rdt8584lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b601580-3091-4d8c-9718-1367c7ed385f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8ba1042-fcfd-47a8-aa0f-8b13618d3212"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8ba1042-fcfd-47a8-aa0f-8b13618d3212"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "21bda883-4037-4b29-95fc-2e5d0c901e4e", "name": "tr(r:p1rdt10491-p1rdt10491lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4737e613-8cf5-45d7-a3f5-71af051ece4c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8f14e6e-ee96-4ae9-86ba-4a07cf103b65"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8f14e6e-ee96-4ae9-86ba-4a07cf103b65"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482", "name": "", "limit_type": "max", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "base"}}, "value": {"value": 600.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}}, {"uuid": "d17ac250-39de-4755-ab93-d93c9ffec1f4", "name": "3974db24-e8e2-4dea-b6b3-1ce29ed132c9", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 1200.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "33fd2b05-630e-42ac-9ccf-60a8ee3f45c9", "name": "7273acf0-19b9-4e4c-b23c-268bdb215a51", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 900.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "14ee131a-95b9-49c5-b11d-450705732a22", "name": "51a33b90-9eee-4646-b0aa-862f7255c6b3", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 165.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "6ba5defb-3101-4ef8-8d06-36719f7dad94", "name": "27d4ced8-b2f8-4ebb-af19-64e0d6a72831", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 151.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "fa89ef5e-f965-457f-a553-4831f61b03c7", "name": "c53fbbfe-4cda-4768-ab94-259d70acb568", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 301.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "cbd826fb-5ba3-44b3-9c68-e5792dbd9854", "name": "62927506-2fbe-4764-b56a-e2ec536f5a4d", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 205.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "99530725-fc4c-4216-8e67-a4469035c280", "name": "0c3473a8-3f24-4fba-b819-b37916068d57", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 295.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523", "name": "179bf9a8-7aaa-4d22-8e36-ca540eaba4ff", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 325.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "fc796329-2b2a-43b9-80c9-88427ef9b994", "name": "0806190a-92f7-42c1-b527-04504919e640", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 233.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "4900e609-ebb1-44db-852b-602449095f15", "name": "5df7dfb1-43ab-41a2-9a13-560098cbf260", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 205.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "40a26197-da2a-4e22-a50a-3922efd7762c", "name": "08f3b6b5-1bbd-40e6-8b34-a1d59d7b57e2", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0412]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.7627]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[7.69673]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 165.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "3baa725a-9b39-45f8-86af-c6afda2cdf9f", "name": "92be5f47-025f-41ac-a0e4-09323ff980fd", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "2419ddcd-627b-4faa-9878-65d4baf7d064", "name": "c9f25e4e-fbf4-4152-a503-2fdd1553b4c9", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "ab2720f4-bdaa-4e93-a718-9d3398ce76a4", "name": "840ea5ca-ca79-4640-abfc-a248810bef2f", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 301.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "c01372a2-4296-4877-a1f3-dd8c06d37f74", "name": "f3d3a255-32e5-4fb0-9516-d898bf9ec850", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 370.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "42f228c5-d3cc-4ea7-9d1c-029acf33213c", "name": "3p_oh_code_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.22464633333333334, 0.05016533333333334, 0.05016533333333334], [0.05016533333333334, 0.22464633333333334, 0.05016533333333334], [0.05016533333333334, 0.05016533333333334, 0.22464633333333334]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.631065, 0.188089, 0.188089], [0.188089, 0.631065, 0.188089], [0.188089, 0.188089, 0.631065]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[2.8000000000000003, -0.6, -0.6], [-0.6, 2.8000000000000003, -0.6], [-0.6, -0.6, 2.8000000000000003]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 480.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "72184ad1-d36c-4223-8c4b-6bdd0563907c", "name": "breaker_13kv_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1e-05, 0.0, 0.0], [0.0, 1e-05, 0.0], [0.0, 0.0, 1e-05]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1e-05, 0.0, 0.0], [0.0, 1e-05, 0.0], [0.0, 0.0, 1e-05]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[2.8000000000000003, -0.6, -0.6], [-0.6, 2.8000000000000003, -0.6], [-0.6, -0.6, 2.8000000000000003]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 1200.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "9faab192-2f24-4afc-9a9c-210e7b431e38", "name": "breaker_69kv_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1e-05, 0.0, 0.0], [0.0, 1e-05, 0.0], [0.0, 0.0, 1e-05]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1e-05, 0.0, 0.0], [0.0, 1e-05, 0.0], [0.0, 0.0, 1e-05]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[2.8000000000000003, -0.6, -0.6], [-0.6, 2.8000000000000003, -0.6], [-0.6, -0.6, 2.8000000000000003]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 900.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0", "name": "1p_oh_al_4_periwinkle_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.7609666666666666, 0.3959666666666668], [0.3959666666666668, 1.7609666666666666]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.6698333333333334, 0.5686333333333333], [0.5686333333333333, 0.6698333333333334]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[36.92503333333334, -17.558966666666667], [-17.558966666666667, 36.92503333333334]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934", "name": "1p_oh_al_4/0_zuzara_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.4728, 0.20209999999999997], [0.20209999999999997, 0.4728]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.21353333333333335, 0.12473333333333335], [0.12473333333333335, 0.21353333333333335]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[41.3578, -20.447400000000002], [-20.447400000000002, 41.3578]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580", "name": "1p_oh_al_2/0_rucina_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.7166333333333332, 0.28753333333333336], [0.28753333333333336, 0.7166333333333332]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.28883333333333333, 0.1932333333333333], [0.1932333333333333, 0.28883333333333333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[39.3595, -19.342100000000002], [-19.342100000000002, 39.3595]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "2d347746-0969-4a8a-b986-c40ef4f4c015", "name": "1p_oh_al_2/0_rucina_2_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.7166333333333332, 0.28753333333333336], [0.28753333333333336, 0.7166333333333332]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.28883333333333333, 0.1932333333333333], [0.1932333333333333, 0.28883333333333333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[39.3595, -19.342100000000002], [-19.342100000000002, 39.3595]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 300.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f", "name": "1p_ug_al_1/0_brenau_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.9149, 0.3744], [0.3744, 0.9149]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.4972667, 0.3969667], [0.3969667, 0.4972667]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[36.4998, -16.313099999999995], [-16.313099999999995, 36.4998]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 205.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "09abe480-4eaa-43f7-a172-88856f758284", "name": "1p_oh_al_2/0_rucina_2_5", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.7166333333333332, 0.28753333333333336], [0.28753333333333336, 0.7166333333333332]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.28883333333333333, 0.1932333333333333], [0.1932333333333333, 0.28883333333333333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[39.3595, -19.342100000000002], [-19.342100000000002, 39.3595]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 233.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "3c9c08f9-58e9-4367-aee8-72788caa6a7c", "name": "1p_ug_al_2/0_converse_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.7793333, 0.3503333], [0.3503333, 0.7793333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.4209333, 0.3231333], [0.3231333, 0.4209333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[37.42527, -17.11183], [-17.11183, 37.42527]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 233.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398", "name": "1p_ug_al_4/0_sweetbriar_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.5462333, 0.2755333], [0.2755333, 0.5462333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.2976, 0.2043], [0.2043, 0.2976]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[39.3278, -18.6046], [-18.6046, 39.3278]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 301.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "97e8fcf2-7304-40bf-ae9b-e7cdd37a4fb7", "name": "1p_oh_al_4/0_zuzara_2_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.4728, 0.20209999999999997], [0.20209999999999997, 0.4728]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.21353333333333335, 0.12473333333333335], [0.12473333333333335, 0.21353333333333335]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[41.3578, -20.447400000000002], [-20.447400000000002, 41.3578]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 165.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "52d0c8fb-a66f-4033-93f4-79e9ae946d79", "name": "1p_oh_al_2/0_rucina_2_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.7166333333333332, 0.28753333333333336], [0.28753333333333336, 0.7166333333333332]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.28883333333333333, 0.1932333333333333], [0.1932333333333333, 0.28883333333333333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[39.3595, -19.342100000000002], [-19.342100000000002, 39.3595]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 165.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137", "name": "1p_oh_al_acsr_#2_sparrow_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0412]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.7627]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[7.69673]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 165.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "1369a137-ea26-496f-a49e-07fe1c36db1c", "name": "1p_ug_al_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.9176999999999998]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.9546999999999999]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[158.492]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 151.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "6148f90f-6cfa-4038-a641-2905e51ba219", "name": "3p_oh_al_acsr_4/0_penguin_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.3635667, 0.09006667, 0.09006667], [0.09006667, 0.3635667, 0.09006667], [0.09006667, 0.09006667, 0.3635667]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.6385333, 0.2202333, 0.2202333], [0.2202333, 0.6385333, 0.2202333], [0.2202333, 0.2202333, 0.6385333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[7.4482669999999995, -3.1846329999999994, -3.1846329999999994], [-3.1846329999999994, 7.4482669999999995, -3.1846329999999994], [-3.1846329999999994, -3.1846329999999994, 7.4482669999999995]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 325.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "39368021-558c-46e1-b3b2-1376e7863046", "name": "3p_ug_al_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.3289333, 0.05923333, 0.05923333], [0.05923333, 0.3289333, 0.05923333], [0.05923333, 0.05923333, 0.3289333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.9076, 0.6647, 0.6647], [0.6647, 0.9076, 0.6647], [0.6647, 0.6647, 0.9076]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[120.289, -59.026, -59.026], [-59.026, 120.289, -59.026], [-59.026, -59.026, 120.289]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 295.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9", "name": "3p_ug_al_350kcmil_3_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.3388667, 0.1744667, 0.1744667], [0.1744667, 0.3388667, 0.1744667], [0.1744667, 0.1744667, 0.3388667]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.5126, 0.2912, 0.2912], [0.2912, 0.5126, 0.2912], [0.2912, 0.2912, 0.5126]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[164.36499999999998, -81.63499999999999, -81.63499999999999], [-81.63499999999999, 164.36499999999998, -81.63499999999999], [-81.63499999999999, -81.63499999999999, 164.36499999999998]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 370.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "3bc006be-04ae-45f9-8629-fd4cc42dcf20", "name": "3p_oh_al_acsr_1033kcmil_curlew_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.0871, 0.0296, 0.0296], [0.0296, 0.0871, 0.0296], [0.0296, 0.0296, 0.0871]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.5382333, 0.1839333, 0.1839333], [0.1839333, 0.5382333, 0.1839333], [0.1839333, 0.1839333, 0.5382333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[8.6745, -3.8842, -3.8842], [-3.8842, 8.6745, -3.8842], [-3.8842, -3.8842, 8.6745]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 960.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "5c14e22a-39e2-4cbb-9aec-056684ef40fa", "name": "padswitch_1_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 165.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "b97451c9-daac-45bb-a300-842ddcc87c76", "name": "padswitch_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 151.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "71edde96-3e63-4b16-8a12-0f7c3c2771f1", "name": "padswitch_1_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 301.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "6b25b103-d37c-42ce-9c2a-4fed44a4146e", "name": "padswitch_1_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 205.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "b8abe50a-d021-449e-a17c-f73c1142aee4", "name": "padswitch_3_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.499563, -0.1093613, -0.1093613], [-0.1093613, 3.499563, -0.1093613], [-0.1093613, -0.1093613, 3.499563]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 295.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "140f67fe-0cf8-45a3-8e1d-7cd225dab6f1", "name": "padswitch_3_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.499563, -0.1093613, -0.1093613], [-0.1093613, 3.499563, -0.1093613], [-0.1093613, -0.1093613, 3.499563]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 325.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "6ef66588-c56f-4ab4-8152-a7ceffd19280", "name": "padswitch_3_8", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.499563, -0.1093613, -0.1093613], [-0.1093613, 3.499563, -0.1093613], [-0.1093613, -0.1093613, 3.499563]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 233.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "e6fb8431-c064-4a3e-8d04-97f3fe67c4bb", "name": "padswitch_3_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.499563, -0.1093613, -0.1093613], [-0.1093613, 3.499563, -0.1093613], [-0.1093613, -0.1093613, 3.499563]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 205.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "bb659552-de29-4980-948f-b0934dad487c", "name": "fuse_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 325.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "7428d9ad-6003-41e1-acc5-c6e01cb8cae2", "name": "fuse_1_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 165.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "dc9b42df-2b7f-4193-8152-ae871c971371", "name": "fuse_1_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "a0d4e32b-8224-4708-b512-715f8a126cff", "name": "fuse_1_6", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 295.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "1afe4efd-d8e8-446b-970c-e6ba75da4e22", "name": "fuse_1_9", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 233.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "0fcbf486-ed39-4481-96a7-243f013e9f46", "name": "padswitch_1_4", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "b8590a64-3624-43d1-8279-40a7928d98a9", "name": "padswitch_3_6", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.499563, -0.1093613, -0.1093613], [-0.1093613, 3.499563, -0.1093613], [-0.1093613, -0.1093613, 3.499563]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "1cf20eb0-ac1f-4a6f-882e-a5d94dfb8dcb", "name": "padswitch_3_9", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.499563, -0.1093613, -0.1093613], [-0.1093613, 3.499563, -0.1093613], [-0.1093613, -0.1093613, 3.499563]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 301.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "bf5bc40f-4332-47bf-baf6-f15771c7e420", "name": "padswitch_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.499563, -0.1093613, -0.1093613], [-0.1093613, 3.499563, -0.1093613], [-0.1093613, -0.1093613, 3.499563]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 370.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "39499f7e-f729-4218-afda-ccccc72332f9", "name": "fuse_1_5", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 370.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b", "name": "3p_ug_al_3_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.445, 0.1745, 0.1745], [0.1745, 0.445, 0.1745], [0.1745, 0.1745, 0.445]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.5326, 0.2912, 0.2912], [0.2912, 0.5326, 0.2912], [0.2912, 0.2912, 0.5326]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[145.291, -72.088, -72.088], [-72.088, 145.291, -72.088], [-72.088, -72.088, 145.291]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 285.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "e7b097f2-bcb0-4abe-b9b3-be9ec78c74f4", "name": "", "__metadata__": {"fields": {"module": "gdm.distribution.curve", "type": "TimeCurrentCurve", "serialized_type": "base"}}, "curve_x": {"value": [2.0, 2.1, 3.0, 4.0, 6.0, 22.0, 50.0], "units": "ampere", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Current", "serialized_type": "quantity"}}}, "curve_y": {"value": [300.0, 100.0, 10.1, 4.0, 1.4, 0.1, 0.02], "units": "second", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Time", "serialized_type": "quantity"}}}}, {"uuid": "d467095a-575e-4fb7-991f-4e2cdf643318", "name": "56320575-cdcc-4544-a3e7-3bcae477af01", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 325.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}, "delay": {"value": 0.0, "units": "second", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Time", "serialized_type": "quantity"}}}, "tcc_curve": {"__metadata__": {"fields": {"module": "gdm.distribution.curve", "type": "TimeCurrentCurve", "serialized_type": "composed_component", "uuid": "e7b097f2-bcb0-4abe-b9b3-be9ec78c74f4"}}}}, {"uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770", "name": "f7b2bfa1-8c77-4b62-850d-04620d3799e4", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 165.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}, "delay": {"value": 0.0, "units": "second", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Time", "serialized_type": "quantity"}}}, "tcc_curve": {"__metadata__": {"fields": {"module": "gdm.distribution.curve", "type": "TimeCurrentCurve", "serialized_type": "composed_component", "uuid": "e7b097f2-bcb0-4abe-b9b3-be9ec78c74f4"}}}}, {"uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482", "name": "fb7f7907-38db-42f7-a652-427c0c9d518c", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}, "delay": {"value": 0.0, "units": "second", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Time", "serialized_type": "quantity"}}}, "tcc_curve": {"__metadata__": {"fields": {"module": "gdm.distribution.curve", "type": "TimeCurrentCurve", "serialized_type": "composed_component", "uuid": "e7b097f2-bcb0-4abe-b9b3-be9ec78c74f4"}}}}, {"uuid": "861d64ae-aba6-4135-a3ca-f177438722a2", "name": "c44effc4-af4a-4a90-ba5f-b9ab992a2b0c", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 295.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}, "delay": {"value": 0.0, "units": "second", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Time", "serialized_type": "quantity"}}}, "tcc_curve": {"__metadata__": {"fields": {"module": "gdm.distribution.curve", "type": "TimeCurrentCurve", "serialized_type": "composed_component", "uuid": "e7b097f2-bcb0-4abe-b9b3-be9ec78c74f4"}}}}, {"uuid": "ab93cbf0-52fd-4d3d-a7f9-fd7cb4376fa6", "name": "291ce2f8-f492-4cb6-8b07-5df217ca3f92", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 233.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}, "delay": {"value": 0.0, "units": "second", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Time", "serialized_type": "quantity"}}}, "tcc_curve": {"__metadata__": {"fields": {"module": "gdm.distribution.curve", "type": "TimeCurrentCurve", "serialized_type": "composed_component", "uuid": "e7b097f2-bcb0-4abe-b9b3-be9ec78c74f4"}}}}, {"uuid": "73f75b89-55b4-4a16-9fa1-8771daf3d5be", "name": "8d08090f-ee79-4f79-9907-9e6c53c590a3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 370.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}, "delay": {"value": 0.0, "units": "second", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Time", "serialized_type": "quantity"}}}, "tcc_curve": {"__metadata__": {"fields": {"module": "gdm.distribution.curve", "type": "TimeCurrentCurve", "serialized_type": "composed_component", "uuid": "e7b097f2-bcb0-4abe-b9b3-be9ec78c74f4"}}}}, {"uuid": "29ee0e2a-8445-4b4f-89fe-d9e9555d89de", "name": "sb10_p1rhs7_1247_311", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30052484-94f2-43a3-abb7-9314d4593c20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ed5e3889-e8c8-4215-adb8-9880f8937da5"}}}], "length": {"value": 0.001511744, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "42f228c5-d3cc-4ea7-9d1c-029acf33213c"}}}}, {"uuid": "bac6250f-86a5-4f43-ac97-3014374e1458", "name": "sb10_p1rhs7_1247_313", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23779a0d-9859-4591-b4ce-7ec704401d42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1548dd91-bc3d-4a2c-903f-48e11159c558"}}}], "length": {"value": 0.001511744, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "42f228c5-d3cc-4ea7-9d1c-029acf33213c"}}}}, {"uuid": "fdee7cd2-4531-4679-9430-6cddbb1eda85", "name": "sb10_p1rhs7_1247_310", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4d9a6e8-eb1b-454c-ae94-2eb435218fb9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14208aa5-3197-4c90-adf9-3067dae9b5f9"}}}], "length": {"value": 0.002267616, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "42f228c5-d3cc-4ea7-9d1c-029acf33213c"}}}}, {"uuid": "516b4490-8d2f-4ed7-8c42-cc189f1caec0", "name": "sb10_p1rhs7_1247_312", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2427b8de-af1a-44f8-9774-724e635057fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec7726f8-0afb-4c35-8a1b-0691a8fb400d"}}}], "length": {"value": 0.002267616, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "42f228c5-d3cc-4ea7-9d1c-029acf33213c"}}}}, {"uuid": "acbd5efd-6ad5-4648-8703-0efb1a4b5dd9", "name": "sb10_p1rhs7_1247_354", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "001adbd4-6616-4dce-83d2-025e896ada51"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3856ea8d-83da-4d2e-8f66-fae6c69b5db1"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "d17ac250-39de-4755-ab93-d93c9ffec1f4"}}}}, {"uuid": "2e5e0aa8-9e09-438d-b554-36c2e72760e7", "name": "sb10_p1rhs7_1247_307", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c975b603-30a6-4ed1-bbae-696d1c5b0a3d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23779a0d-9859-4591-b4ce-7ec704401d42"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "d17ac250-39de-4755-ab93-d93c9ffec1f4"}}}}, {"uuid": "5ce19f15-a792-442e-a7fa-fac766595642", "name": "sb10_p1rhs7_1247_305", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6263cae0-e97a-4044-a130-e971a626d3c1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30052484-94f2-43a3-abb7-9314d4593c20"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "d17ac250-39de-4755-ab93-d93c9ffec1f4"}}}}, {"uuid": "7c2d9b1a-6e34-47c2-acf6-91b80aa94d66", "name": "sb10_p1rhs7_1247_303", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3856ea8d-83da-4d2e-8f66-fae6c69b5db1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c975b603-30a6-4ed1-bbae-696d1c5b0a3d"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "d17ac250-39de-4755-ab93-d93c9ffec1f4"}}}}, {"uuid": "069db73a-656d-42e0-906b-02395eb7257b", "name": "sb10_p1rhs7_1247_347", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16bb904e-b153-4b0a-97f5-53ad7c6606d8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ca7962b4-686c-4bee-af8d-f1851b835adb"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "33fd2b05-630e-42ac-9ccf-60a8ee3f45c9"}}}}, {"uuid": "a60ebb51-1b37-43c3-859c-de42675fe34f", "name": "sb10_p1rhs7_1247_306", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c975b603-30a6-4ed1-bbae-696d1c5b0a3d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2427b8de-af1a-44f8-9774-724e635057fb"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "d17ac250-39de-4755-ab93-d93c9ffec1f4"}}}}, {"uuid": "ffaf79ca-5c18-46fc-b1af-dc55f22795b8", "name": "sb10_p1rhs7_1247_304", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6263cae0-e97a-4044-a130-e971a626d3c1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4d9a6e8-eb1b-454c-ae94-2eb435218fb9"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "d17ac250-39de-4755-ab93-d93c9ffec1f4"}}}}, {"uuid": "a2e353c7-8d1a-4863-a935-f26557420635", "name": "sb10_p1rhs7_1247_349", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ca7962b4-686c-4bee-af8d-f1851b835adb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "574ab810-c1b0-4662-8c4d-f32ab6893a36"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "33fd2b05-630e-42ac-9ccf-60a8ee3f45c9"}}}}, {"uuid": "ecd0c793-0eab-4a56-992b-f4cdf28c9fb5", "name": "sb10_p1rhs7_1247_302", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3856ea8d-83da-4d2e-8f66-fae6c69b5db1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6263cae0-e97a-4044-a130-e971a626d3c1"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "d17ac250-39de-4755-ab93-d93c9ffec1f4"}}}}, {"uuid": "a596de2d-c583-495c-8e87-684ff992d13b", "name": "l(r:p1rdt4964lv-p1rlv10170)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3541a1a-9680-4baf-9b87-a1322cb1a16a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02e86824-b793-4080-9401-c6995a365baf"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "9679fe35-fbbc-45a3-973d-24b473884602", "name": "l(r:p1rdt4980lv-p1rlv10189)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab731358-e17f-4c48-b6f8-c7bb4c7701de"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58f2b2c3-4f6f-4fd2-abb9-42ff665692bd"}}}], "length": {"value": 0.0491385, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ba04e182-afcb-48fa-9746-2e11559cb473", "name": "l(r:p1rdt4980lv-p1rlv10574)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab731358-e17f-4c48-b6f8-c7bb4c7701de"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b4caeee-6304-4a25-a7d8-44c6014b5e37"}}}], "length": {"value": 0.0298046, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "228b5f7b-dac5-4b0e-b0b1-3a389c3dc040", "name": "l(r:p1rdt4980lv-p1rlv10596)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab731358-e17f-4c48-b6f8-c7bb4c7701de"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aad9ea92-9403-4ac0-9aaf-7e845b8c7bb5"}}}], "length": {"value": 0.0197463, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6c6b3bb5-9c25-4716-a167-aace2b875e2e", "name": "l(r:p1rdt5017lv-p1rlv10262)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0375d197-ccd2-4ed8-9439-857b700cefb8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3317d7c2-2588-426d-91fc-3d765b932da6"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "e4d5b6e9-1c05-4376-8081-8308282a46d2", "name": "l(r:p1rdt5126lv-p1rlv10491)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e33e473-8d5b-4704-bdab-56032991f94e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f7116b9-96c1-42c8-850f-7787f5fd0f96"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "fbef4d18-a197-429d-828d-09390792d6c2", "name": "l(r:p1rdm10619-p1rlv10521)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd4b469b-001b-4914-8e51-e98fe3f6babb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31f26b28-fc9d-4b3d-b204-cf40f3478c44"}}}], "length": {"value": 0.0680764, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "148f5acc-b8c0-4d21-a617-7244a63c718e", "name": "l(r:p1rdm10620-p1rlv10641)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e28a5f3a-4447-469a-85dd-e232d8c6d728"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73ada6ad-ace7-46c1-80f7-2cb33cf4cdb3"}}}], "length": {"value": 0.03407530000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "45d46b87-bb36-48a2-8d53-0a55675034bf", "name": "l(r:p1rdm10619-p1rdm10620)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd4b469b-001b-4914-8e51-e98fe3f6babb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e28a5f3a-4447-469a-85dd-e232d8c6d728"}}}], "length": {"value": 0.0178464, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f38d4a07-13c3-4b95-ae7c-7c6b7d041360", "name": "l(r:p1rdm10619-p1rdt5140lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f114a56-98d7-4fe8-b0b1-b8c4bc791cf9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd4b469b-001b-4914-8e51-e98fe3f6babb"}}}], "length": {"value": 0.0178464, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "2d347746-0969-4a8a-b986-c40ef4f4c015"}}}}, {"uuid": "d351709b-972b-4d55-8d6e-f82dce2d848d", "name": "l(r:p1rdm10621-p1rlv20071)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e09d217e-44a5-4013-8d48-8546d6bb1dc3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07f95ba5-92dd-465f-a38d-8e878243262b"}}}], "length": {"value": 0.0125414, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6b760518-573f-4b9d-a363-83b3bb356359", "name": "l(r:p1rdm10621-p1rdt5140lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f114a56-98d7-4fe8-b0b1-b8c4bc791cf9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e09d217e-44a5-4013-8d48-8546d6bb1dc3"}}}], "length": {"value": 0.0178464, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ec0ee5c6-d17f-48f6-bfe3-c14274d5bfb6", "name": "l(r:p1rdt5142lv-p1rlv10523)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e071635-4071-470d-be09-4484cb90441a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35d47036-a044-4c67-b5b5-0006e2a3b68e"}}}], "length": {"value": 0.019072, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8bc645f7-1f0e-434d-bacc-53e73e4258fe", "name": "l(r:p1rdt5142lv-p1rlv10616)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e071635-4071-470d-be09-4484cb90441a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a5717e0-080e-46ae-918a-64fe4fcba5d7"}}}], "length": {"value": 0.019072, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "587cec7d-7000-4cf3-9010-3f39f71a3747", "name": "l(r:p1rdt5153lv-p1rlv10538)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ec20ad2-b04f-43fc-ad8d-d41746549a57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a302271d-4cf3-45ff-9308-b9cf31fbefa3"}}}], "length": {"value": 0.052564700000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "ebfd9db5-3ac9-4827-98f7-d190caca7cdf", "name": "l(r:p1rdt5153lv-p1rlv10586)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ec20ad2-b04f-43fc-ad8d-d41746549a57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfbe5665-c020-455a-addc-d3f9514735ed"}}}], "length": {"value": 0.0379881, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "d76eb6de-93b6-410f-955e-c8305a62dbe6", "name": "l(r:p1rdt5153lv-p1rlv10610)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ec20ad2-b04f-43fc-ad8d-d41746549a57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b91354e-ce50-44d0-a959-fa451bb9cf20"}}}], "length": {"value": 0.0253548, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "7f0e2518-b943-445a-b36b-df23de1add14", "name": "l(r:p1rdt5155lv-p1rlv10540)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85351f49-cb19-4f71-a6ae-a21f5a48af6f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4829cd2f-7e61-4386-89ce-89d77d5ef5cf"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "5e07c049-b3d7-4d1a-9c10-f0144ef0ecfe", "name": "l(r:p1rdt5159lv-p1rlv10544)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba7e3a6b-f62f-432f-afe7-2ebbfc9abd59"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c722b89-fdaf-416f-863e-02b443375ba1"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "082ef98e-736d-4b9d-8761-8e1f28430622", "name": "l(r:p1rdt5172lv-p1rlv10563)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48efdcb9-083c-4e17-a1d2-acb1388f085e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8a10822-398f-441e-a5ca-73303d832183"}}}], "length": {"value": 0.0709049, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "de3f7150-cc4b-4cdd-8586-d90b3e9f0791", "name": "l(r:p1rdt5179lv-p1rlv10573)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd4155b2-ca55-41d7-bd35-98a5eec8c39a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94677ede-fd5c-4fbb-bfcd-98cf67b56913"}}}], "length": {"value": 0.0550518, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3957c039-612c-45ec-869b-4310f9d481bb", "name": "l(r:p1rdt5179lv-p1rlv10583)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd4155b2-ca55-41d7-bd35-98a5eec8c39a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0431d17-75da-48c1-965c-875f61b0e9bf"}}}], "length": {"value": 0.0550518, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0997b3ce-c275-4e58-aafb-272b62d6c6b6", "name": "l(r:p1rdt5180lv-p1rlv10576)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae26acb3-c2c9-479c-9d19-c30bf00aa8c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25141e20-0a65-4905-b37f-954ed1a8751c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "e5f30957-f466-42ef-b23f-40321acb3168", "name": "l(r:p1rdt5183lv-p1rlv10582)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bbde2e8-42c0-486b-9759-78898d177f93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdfa726f-5606-4ae2-b358-ad664dd7b0e3"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b6b313aa-24d6-40ba-afd6-6230958c1568", "name": "l(r:p1rdt5184lv-p1rlv10589)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1656cc28-8a5b-40da-887f-25605dd336aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53019a8a-b453-4add-9d2d-e4ab380fce67"}}}], "length": {"value": 0.0161579, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "55582f95-1e69-4d6b-b0db-f4b4992538e3", "name": "l(r:p1rdt5184lv-p1rlv10600)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1656cc28-8a5b-40da-887f-25605dd336aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "feb19590-c5f4-4982-9e99-20599f08cfe7"}}}], "length": {"value": 0.0127667, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "87f828d3-1f6d-403b-852d-3f8e3c7b7b65", "name": "l(r:p1rdt5184lv-p1rlv10621)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1656cc28-8a5b-40da-887f-25605dd336aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "374d5417-b2c4-4d16-9b91-d2f519921fd8"}}}], "length": {"value": 0.0240219, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3b197939-0e9a-4bb2-97a0-2ba01199fb47", "name": "l(r:p1rdt5195lv-p1rlv10615)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf05c1bb-39cc-48b3-a576-18913e0cff13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b175fcb-d1ee-44eb-8f89-826e40c5db1d"}}}], "length": {"value": 0.00593856, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9cd169ad-8154-4e21-addc-d48efa048977", "name": "l(r:p1rdt5195lv-p1rlv10634)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf05c1bb-39cc-48b3-a576-18913e0cff13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3184f056-3b5f-403d-86a0-f9b28d6bb3e3"}}}], "length": {"value": 0.018580700000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d25b1b60-f739-427b-bb68-d15d2a530266", "name": "l(r:p1rdt5200lv-p1rlv10627)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "03e7bfdb-ff8b-4142-95ef-8d848ff5d2db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32406d7d-51f9-4c16-900b-526985e5f62b"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "1695160c-d7a9-4b56-a36a-9bf4c210266e", "name": "l(r:p1rdt5201lv-p1rlv10629)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8162a8c-5339-4f42-bd7a-b6dbc5ff463b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e183b3e8-d995-4f1e-baee-8d9d4add157e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "91226eb3-4986-4099-afcc-ba8a616753bc", "name": "l(r:p1rdt5202lv-p1rlv10630)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "39eaedd7-75b6-449f-8ff6-6e31f6e74504"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d60a935-dc9b-48ea-8ee7-9b682452035e"}}}], "length": {"value": 0.0271144, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4ab0b458-002d-4941-8fb5-8fa003f96669", "name": "l(r:p1rdt5206lv-p1rlv10637)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "599a2995-33d5-4bcc-8cd3-585ea37577cd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9510bd0-2bba-4522-bfbe-20b94ea400b6"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "24998fa4-29c5-43de-8a56-451bf7088b34", "name": "l(r:p1rdt5218lv-p1rlv10663)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c650eda9-132b-4419-a055-ad68037c7772"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8198c1c5-67e0-49b9-b11a-1f266f7f4bcb"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "4f0bce0b-cec8-4270-90da-19caf6b4f966", "name": "l(r:p1rdt5236lv-p1rlv10720)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f252d81-66ee-40a6-bce7-2891e06b39e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3d48c0e-704d-4205-94a2-ee74be7ae350"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "52f0d3a1-455d-4799-a4f4-b36bd83a3789", "name": "l(r:p1rdt5342lv-p1rlv10955)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e01069aa-388b-4362-9d02-a164f173dc20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75dbf8f0-4cb6-49b7-a2a5-f98e9ff4b8df"}}}], "length": {"value": 0.017914800000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8823cd6f-545e-4acd-bd12-eea1e38174b4", "name": "l(r:p1rdt5342lv-p1rlv11048)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e01069aa-388b-4362-9d02-a164f173dc20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a8fc823-6fe8-4a3b-9437-68aa751f5e3b"}}}], "length": {"value": 0.017914800000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d01caf79-b234-437a-9476-0490ec03d12d", "name": "l(r:p1rdt5472lv-p1rlv11380)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34a1276e-c702-4c69-b7b1-566d400da2de"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f949a06a-817e-4666-95bb-9536ce06a694"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b63446ac-e79f-48cf-b564-dee1da12a798", "name": "l(r:p1rdt5475lv-p1rlv11384)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d181674-9355-488b-8a3f-5b7c844c35a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0c23aea-471f-4d10-9500-1bc14a67d7e7"}}}], "length": {"value": 0.0318484, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "07dc8977-0ddc-41bf-98a9-8dfec5f9d3b4", "name": "l(r:p1rdt5475lv-p1rlv11386)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d181674-9355-488b-8a3f-5b7c844c35a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f512d86-c9d9-4f58-9d5a-418d0732dc94"}}}], "length": {"value": 0.008446400000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9d9f36bf-d24f-4ab2-a186-fcf4cf92cb27", "name": "l(r:p1rdt5475lv-p1rlv11397)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d181674-9355-488b-8a3f-5b7c844c35a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fd316b0-fd98-4193-9c1b-aaa7d92a4284"}}}], "length": {"value": 0.0375424, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f8c8391e-0f26-45c6-aa81-d7d2ebd35f26", "name": "l(r:p1rdt5476lv-p1rlv11385)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0888f4c5-e037-4891-99fb-fd43934ffae0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2115e8bb-fe49-49ad-8687-68feca212557"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "54f88b11-22f1-4b51-9851-8a348fa7f66b", "name": "l(r:p1rdt5477lv-p1rlv11387)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fafd64c3-efe5-4684-b06f-44e4c8555aa4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbca8c57-0da4-4368-9821-7a9ca4282173"}}}], "length": {"value": 0.0726843, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4ecd7eab-ac7e-4a24-ac86-8a3f9931e089", "name": "l(r:p1rdt5478lv-p1rlv11388)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5107bc9c-f463-49f6-a92f-23c5730475e2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12377bf0-f258-4c29-ab26-e938c95ee25c"}}}], "length": {"value": 0.0557394, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "38a0fb7e-0479-4716-ad92-ef062f819e5b", "name": "l(r:p1rdt5478lv-p1rlv11398)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5107bc9c-f463-49f6-a92f-23c5730475e2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97aa01fe-2e60-4617-8c89-d36f425087fe"}}}], "length": {"value": 0.0557394, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b3073021-9bde-4166-9c27-e2551b7120aa", "name": "l(r:p1rdm11569-p1rlv11390)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "004f56b2-ec94-4189-91b8-46b4af22faa6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b6420b1-3456-42fc-9266-c2b84e063cec"}}}], "length": {"value": 0.110315, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "de9801d0-ebc2-474b-85f2-d670474b0d18", "name": "l(r:p1rdm11569-p1rdt5480lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44ac9e38-8ae3-4102-822b-1c638a6c878a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "004f56b2-ec94-4189-91b8-46b4af22faa6"}}}], "length": {"value": 0.0194577, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "be1cb5ab-a890-4c9b-8c5d-ca7990b7fa8b", "name": "l(r:p1rdm11570-p1rlv11401)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8be902f6-4cca-4ce5-9f73-a1f96c65d8ef"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a215d7dd-8081-4355-9c38-4fd3d2c859c7"}}}], "length": {"value": 0.0577794, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c8464817-2597-4ffb-9d58-991b40d0d49f", "name": "l(r:p1rdm11570-p1rdt5480lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44ac9e38-8ae3-4102-822b-1c638a6c878a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8be902f6-4cca-4ce5-9f73-a1f96c65d8ef"}}}], "length": {"value": 0.0194641, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "878ec4a9-cef2-42e8-8ff1-768ea4ee08b7", "name": "l(r:p1rdt5481lv-p1rlv11392)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f213ee9e-6ae7-4e82-9f25-6fc456f45576"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e740a352-ac8f-4ae2-ace3-254fccd7f96f"}}}], "length": {"value": 0.00971421, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "27b93701-b086-409f-b6c4-248ad3a79eab", "name": "l(r:p1rdt5481lv-p1rlv11394)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f213ee9e-6ae7-4e82-9f25-6fc456f45576"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "996d3e44-142c-42fa-bf4f-2bd1777122dd"}}}], "length": {"value": 0.00971421, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d927f88c-f87d-4609-b7d9-3b440a8942a8", "name": "l(r:p1rdt5483lv-p1rlv11395)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a73d544-9f33-49d9-b648-c806addf3c06"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29922f55-f36a-4b9e-8836-5f9dadd641b7"}}}], "length": {"value": 0.0408239, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b45fdc13-573f-4d62-8969-6d807aee8b95", "name": "l(r:p1rdt5485lv-p1rlv11399)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40eaefce-482f-4a89-bec1-2c11bac2bfb7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68a9eead-8197-4e82-a444-2a4544ec9ddb"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "400b640e-346e-4663-9421-ff28dce9686e", "name": "l(r:p1rdt5650lv-p1rlv11671)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28a6e44b-c6c7-4556-b4d8-d55359391c66"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "834a5733-5264-4adf-861a-25e494df3e37"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "2f30c2bf-be3e-4b60-a6e7-231231e94831", "name": "l(r:p1rdt5653lv-p1rlv11674)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38d1de19-1f51-4875-acc2-a75e3d1a290e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "45f2a901-e4f7-4055-a3e2-b60c61d5033e"}}}], "length": {"value": 0.0467126, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f1e52a68-1c9c-4651-b590-c66946bb5bd9", "name": "l(r:p1rdt5656lv-p1rlv11677)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "87e8c57e-67ff-439c-b28b-0fbdbfd62ea6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b2f121a-2202-43c0-8684-81913a5d6ea9"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "cd9590d2-b2ef-45a1-a2a0-7879503ae2da", "name": "l(r:p1rdt5662lv-p1rlv11684)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea73a91a-b052-486e-810b-1a5ad281e07b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02aef971-5f4a-4ca8-aa33-cce34517bd44"}}}], "length": {"value": 0.0429078, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0d0ec938-717a-4694-87b7-c4ffcc8becc4", "name": "l(r:p1rdt5663lv-p1rlv11686)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16a67a88-5d11-4eca-85fe-38c948ad362c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cda8e361-98b6-49bd-a3ff-30a036a3dc6f"}}}], "length": {"value": 0.0119369, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e9a6d297-511a-4374-baa4-5957c5a9660a", "name": "l(r:p1rdm11909-p1rlv15645)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5b71ca5-a7ab-42f7-824a-bc43fc1708cc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "449098c3-4f65-4350-863f-4b7bc1f14493"}}}], "length": {"value": 0.043632500000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1ac2f810-c321-44b7-95e4-0c2294035bca", "name": "l(r:p1rdm11909-p1rdt5663lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16a67a88-5d11-4eca-85fe-38c948ad362c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5b71ca5-a7ab-42f7-824a-bc43fc1708cc"}}}], "length": {"value": 0.0154548, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "367b85dd-74f1-4252-bf45-811d7899bfaa", "name": "l(r:p1rdt5728lv-p1rlv11779)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6d456893-4d89-455a-b1a5-4863aad6293a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0ba1408-17da-4678-8b04-90c616c3fb48"}}}], "length": {"value": 0.0661386, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "fadcfd18-1437-4d57-ae07-5feb2b125a65", "name": "l(r:p1rdt5728lv-p1rlv11783)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6d456893-4d89-455a-b1a5-4863aad6293a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3890375-c01d-44d2-93f9-8d9d60da8852"}}}], "length": {"value": 0.0661386, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f3b9d6c3-246a-4d60-9f2a-b29050a691c1", "name": "l(r:p1rdt5729lv-p1rlv11780)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95f81d7a-a6af-4843-bfa1-002abc7ff870"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e9a574d-9537-417a-a811-e22d84b8ea53"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b41f8809-5b99-439f-9bd6-a6fc8cb47c7c", "name": "l(r:p1rdt5730lv-p1rlv11784)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2dd206bc-965d-46c9-8fdb-8c158c7bba05"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b66df0bc-6159-42fa-bf49-b8ad17d0e6aa"}}}], "length": {"value": 0.0506895, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2c42071d-569c-4f35-8d65-90380f97501d", "name": "l(r:p1rdt5730lv-p1rlv11786)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2dd206bc-965d-46c9-8fdb-8c158c7bba05"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b15fc66-89d9-483b-9c9f-9b0f39a63b29"}}}], "length": {"value": 0.024148300000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2b57623a-601b-4dbd-bc38-661889b37a6b", "name": "l(r:p1rdm12071-p1rlv11781)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64ee7f4c-b91a-4a25-b85d-a91b83777c1f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28fd9f7c-0195-4529-a972-aa60eced47d2"}}}], "length": {"value": 0.0191276, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3d9ddc49-14e7-4dd7-a2c5-d98beb0d3444", "name": "l(r:p1rdm12071-p1rdt5730lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2dd206bc-965d-46c9-8fdb-8c158c7bba05"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64ee7f4c-b91a-4a25-b85d-a91b83777c1f"}}}], "length": {"value": 0.0173818, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8b230ec6-5ef9-47a7-990c-fafb6e26a6c3", "name": "l(r:p1rdt5731lv-p1rlv11782)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e414162-eda7-4cf2-9116-fc24af9461bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "496fc854-bbf8-463b-b16c-12dd1b444cc6"}}}], "length": {"value": 0.0292119, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a73dcae4-6fc0-4b6f-a432-3cb5ef33058b", "name": "l(r:p1rdm12075-p1rlv11785)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7103c2f0-8160-434f-b4b3-edfbd7e97464"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ed0eb774-fcc3-417f-a8a4-fbdb825cc106"}}}], "length": {"value": 0.0190573, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d6dbe381-462c-408e-87b7-e82db0872b88", "name": "l(r:p1rdm12075-p1rdt5731lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e414162-eda7-4cf2-9116-fc24af9461bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7103c2f0-8160-434f-b4b3-edfbd7e97464"}}}], "length": {"value": 0.0194685, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "40793b09-be51-4c19-855d-a9cab1a29975", "name": "l(r:p1rdt5840lv-p1rlv12028)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9974869d-7d87-4a27-9606-076cd7799953"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1dfd848-b639-41b5-ad95-2c03a51bd36b"}}}], "length": {"value": 0.0166971, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "59eddbe0-cc88-4acf-aab0-ee9589891212", "name": "l(r:p1rdt5840lv-p1rlv12157)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9974869d-7d87-4a27-9606-076cd7799953"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc4d79bb-8ba3-4146-9d50-16db48ffec22"}}}], "length": {"value": 0.0166971, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "80b0ac16-51ce-4b22-8d60-68d9d40dc483", "name": "l(r:p1rdt5923lv-p1rlv12214)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "751d2f2e-bb6f-4ca6-9e86-0e2b5ff3f92a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df9d9de2-6929-48a4-a390-c0e2f129b374"}}}], "length": {"value": 0.0436747, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "55166bbd-4d92-45f6-90c8-7e525148435b", "name": "l(r:p1rdt5923lv-p1rlv12217)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "751d2f2e-bb6f-4ca6-9e86-0e2b5ff3f92a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4d26673-c304-41de-8b5b-149552601ba4"}}}], "length": {"value": 0.0140011, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8cba7cbc-61c9-40c7-a472-15ba57ed7cc2", "name": "l(r:p1rdt5923lv-p1rlv12222)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "751d2f2e-bb6f-4ca6-9e86-0e2b5ff3f92a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cee79fe8-f140-4be9-aa6b-d56e37fb6857"}}}], "length": {"value": 0.06246270000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d23744d0-51a4-42f6-a714-7ca8bc4f452a", "name": "l(r:p1rdt5923lv-p1rlv12225)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "751d2f2e-bb6f-4ca6-9e86-0e2b5ff3f92a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8e1f797-9417-447c-8a08-cf00a462ef14"}}}], "length": {"value": 0.0351977, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "5163b09b-32f5-4b89-8d37-f90900ee57a4", "name": "l(r:p1rdt6038lv-p1rlv12538)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d654945d-b71d-4943-86a2-5830fca200c9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b42c2471-9114-4042-980e-dd226ad024a3"}}}], "length": {"value": 0.010266900000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "804e6cda-09e4-439b-b278-de2464a271a4", "name": "l(r:p1rdt6043lv-p1rlv12552)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ae7bbf-f53e-4ae2-8145-bf56ce935094"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c42d772-e2a8-45d4-9cf2-2edd7a567b35"}}}], "length": {"value": 0.0181528, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "b31deec8-a68b-4572-a9fa-62a1124c070a", "name": "l(r:p1rdm12875-p1rlv12553)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3e53a11-6c13-4d27-89f2-2abbd28f69ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a29aec49-62a4-41ec-a67c-a84470a23f7b"}}}], "length": {"value": 0.0385577, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "5ee09bf3-d8ba-4f9e-ae22-905ffbba3cfa", "name": "l(r:p1rdm12875-p1rdt6043lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ae7bbf-f53e-4ae2-8145-bf56ce935094"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3e53a11-6c13-4d27-89f2-2abbd28f69ac"}}}], "length": {"value": 0.0560413, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "d6a45977-5d4a-4d99-a466-58bc7bf18e45", "name": "l(r:p1rdm12876-p1rlv12559)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b748c697-b624-43f0-b375-5024d8cff92b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a47101-b6df-473e-9c7b-96e076c17931"}}}], "length": {"value": 0.0120531, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "09aeebd8-f06b-4d31-bf4d-0e7a60792681", "name": "l(r:p1rdm12877-p1rlv12562)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3082eb6b-1a9f-4b6e-930e-f58173fe02ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b0417d3-820d-4daa-aec5-3dcf34e40e00"}}}], "length": {"value": 0.00937768, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "d8bd73cc-9912-47ad-abdb-98e0f3860f40", "name": "l(r:p1rdm12876-p1rdm12877)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b748c697-b624-43f0-b375-5024d8cff92b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3082eb6b-1a9f-4b6e-930e-f58173fe02ac"}}}], "length": {"value": 0.00528266, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "7b24a598-5dca-4ef9-a2fb-eb6cd38fc84c", "name": "l(r:p1rdm12876-p1rdt6043lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ae7bbf-f53e-4ae2-8145-bf56ce935094"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b748c697-b624-43f0-b375-5024d8cff92b"}}}], "length": {"value": 0.0304331, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "388119d6-f740-4a34-b677-297b11d1d4a9", "name": "l(r:p1rdt6046lv-p1rlv12557)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2e2d1a7-039c-4b29-a061-b814ac675e3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fe4d6ae-cca5-476c-981a-a1dcd27b1e84"}}}], "length": {"value": 0.0315499, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "ee6ada67-4f86-4be6-b132-2aad7bf157f5", "name": "l(r:p1rdt6047lv-p1rlv12558)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21e75ccd-7e21-4f0d-890c-81aa6b33b109"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a427f20-861a-4616-9443-265beaeccca3"}}}], "length": {"value": 0.00804165, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "24ad47a8-99be-4c96-9d61-3961533ba7d0", "name": "l(r:p1rdt6208lv-p1rlv12936)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01be483b-09f4-450e-a39d-78692c40ee8b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "019e419c-9f88-455a-bf48-b89531ed9e51"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "3f467e00-f448-4c36-8cb1-d2229235a0d9", "name": "l(r:p1rdt6221lv-p1rlv12959)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73f78740-2ec5-4ad8-b7fb-40f4a72b730e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8418804f-aad5-49df-9916-f427da5089c1"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "fb81f428-e1d6-442c-82a6-cb1c5af44b3c", "name": "l(r:p1rdt6226lv-p1rlv12971)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3154eee7-a1ba-4b9d-9e91-bab55529d358"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be845651-8e1c-4b6d-8633-fcbdfb1fd5d4"}}}], "length": {"value": 0.0550308, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "209ae9db-43f7-4864-9a91-dd599c660b29", "name": "l(r:p1rdt6226lv-p1rlv20185)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3154eee7-a1ba-4b9d-9e91-bab55529d358"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "646058a3-cda7-4723-bd0f-05d305fe7c11"}}}], "length": {"value": 0.0550308, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "baa087fe-f55d-461e-98a8-a7791ca43e18", "name": "l(r:p1rdt6268lv-p1rlv13043)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72ce0706-6b32-4b4b-9bf3-fd1f5a6af5ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3072c6c-3a40-4e49-bd00-febc8268b135"}}}], "length": {"value": 0.038529200000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c319e0c1-2119-4d87-af76-491d2ce8fdec", "name": "l(r:p1rdt6268lv-p1rlv13047)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72ce0706-6b32-4b4b-9bf3-fd1f5a6af5ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4209bdad-276f-4e07-93e0-78b162ce95cf"}}}], "length": {"value": 0.0748394, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "009b3a8c-9e06-4cda-bc24-d2f036ee33a2", "name": "l(r:p1rdt6268lv-p1rlv13054)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72ce0706-6b32-4b4b-9bf3-fd1f5a6af5ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21c6ea4f-ec9d-424e-8743-7175408f9e2c"}}}], "length": {"value": 0.0369069, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a53a4533-5597-4cc6-9369-c1ea467408b4", "name": "l(r:p1rdt6269lv-p1rlv13044)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79c91fa8-15ad-4e8d-96bd-2cad395dd280"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa31c772-8460-4624-a123-64b87ca8d332"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "bc4eed45-5ff4-4307-bb2c-bb2c0189e21a", "name": "l(r:p1rdt6270lv-p1rlv13045)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5adb2083-3d46-48a7-8996-37c0781b0215"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6070414d-09e7-48a7-aec0-c105cc0f1a93"}}}], "length": {"value": 0.034086700000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8b7550b3-6d1b-4305-af43-5cc86d9bf52f", "name": "l(r:p1rdt6270lv-p1rlv13046)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5adb2083-3d46-48a7-8996-37c0781b0215"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5edc15fb-49d5-4052-8fad-4979578f6ed1"}}}], "length": {"value": 0.0160269, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "09abe480-4eaa-43f7-a172-88856f758284"}}}}, {"uuid": "93980ed3-1b22-488f-8670-d1ef74982523", "name": "l(r:p1rdt6270lv-p1rlv13052)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5adb2083-3d46-48a7-8996-37c0781b0215"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86d59550-d7c8-47e1-a6bc-14b2d50de58c"}}}], "length": {"value": 0.04494170000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "786442b2-02c0-49ce-84bc-697eb42f86e0", "name": "l(r:p1rdt6271lv-p1rlv13048)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1335e64c-9f37-4e73-a37f-8f76737cabff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "569078be-37c2-4c05-8455-91945eb7fdb9"}}}], "length": {"value": 0.0901436, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "559c20cc-21df-4271-8c6c-9082c619342d", "name": "l(r:p1rdt6272lv-p1rlv13049)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04422e0a-1952-422d-a201-5fafef1875db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ed85192-4c5a-4c15-ba21-1ba883b03ddd"}}}], "length": {"value": 0.00941805, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f04b5148-7972-4220-8564-2067c13a4eb3", "name": "l(r:p1rdt6272lv-p1rlv13053)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04422e0a-1952-422d-a201-5fafef1875db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e058437-0138-4305-a33e-d8fa61aed8cc"}}}], "length": {"value": 0.00941805, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2f3c609b-2021-408f-8726-e117aee9d249", "name": "l(r:p1rdm13376-p1rlv13051)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b6739c0-1b15-42c1-9fdd-4d7f604a03ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9a855b0-538e-4fab-91f1-93b4ece09409"}}}], "length": {"value": 0.0533824, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1160992a-885e-46ae-b199-876ea6532f62", "name": "l(r:p1rdm13376-p1rdt6274lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1db8c80-e791-4c31-a6f2-713aa665bf41"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b6739c0-1b15-42c1-9fdd-4d7f604a03ce"}}}], "length": {"value": 0.0171039, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f4585475-d917-4176-9105-3c08f98e6ae2", "name": "l(r:p1rdm13377-p1rlv13056)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e395985-4c66-49c9-9252-94d8078b8e8e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16584dfd-537d-4b0d-a651-c73d0beabc6d"}}}], "length": {"value": 0.04504020000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3415f9bf-f574-44ed-b40d-dde7483331f3", "name": "l(r:p1rdm13377-p1rdt6274lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1db8c80-e791-4c31-a6f2-713aa665bf41"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e395985-4c66-49c9-9252-94d8078b8e8e"}}}], "length": {"value": 0.0171039, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7bd303bc-c877-43d3-92ed-7bf8d2e8223a", "name": "l(r:p1rdt6275lv-p1rlv13055)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba567584-fbee-44eb-b3f1-da24a0ce66a0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387df3d3-5f03-47f4-8b16-bea8815e63d1"}}}], "length": {"value": 0.0150884, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ce961dd6-3068-4529-b5b2-7ae148f76be1", "name": "l(r:p1rdt6275lv-p1rlv13058)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba567584-fbee-44eb-b3f1-da24a0ce66a0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c83997dc-872f-494f-8c8a-7266c854fc48"}}}], "length": {"value": 0.0150884, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f7952fba-5181-4715-84ef-6c47236d1571", "name": "l(r:p1rdt6276lv-p1rlv13057)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f20ace2-5ec8-4451-b7e7-66f46c2c487b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c63d163-75bd-4d91-bcfa-229a2e331b1f"}}}], "length": {"value": 0.0435582, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "de4dd982-2e26-43e0-bd9e-d2a4a732efb1", "name": "l(r:p1rdt6276lv-p1rlv13062)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f20ace2-5ec8-4451-b7e7-66f46c2c487b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d2fa164-4c03-4bcd-a386-749ccd4e9001"}}}], "length": {"value": 0.0435582, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "085a1bfb-ff94-46ab-9c2a-9f9baee7d5e7", "name": "l(r:p1rdt6277lv-p1rlv13059)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e582b04d-a8d8-4ee9-8576-1e5941623c0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a1779b5b-1a6c-4511-9d4b-88026b430173"}}}], "length": {"value": 0.00731377, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "87f20977-ad83-4193-8443-34331741b51d", "name": "l(r:p1rdt6278lv-p1rlv13060)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b37eabc-787a-491f-bc4f-956f43a862ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8767a040-da31-48d9-9473-0941856bcedc"}}}], "length": {"value": 0.0214401, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4863f307-9b70-4638-bfb9-09034f350d4b", "name": "l(r:p1rdt6345lv-p1rlv13185)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a38eb6d-a625-42a1-95f6-bbf078d1447a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c29c3206-b71d-41d1-8ad7-a693c8c25d4d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "422ef105-d242-44fb-a517-c36ddd805f83", "name": "l(r:p1rdt6347lv-p1rlv13187)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e40008af-ff50-42bd-8897-f663c27a436f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ffbd17b6-b1a2-4e55-9052-67a84419bb9d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "f4d53aad-8c53-4280-8a58-e354c3deb985", "name": "l(r:p1rdt6348lv-p1rlv13188)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d84ac329-f314-41be-a2ee-89bc74789a18"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67ffcd9f-ba90-4da7-b3b6-46310e321590"}}}], "length": {"value": 0.0371493, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b9f20c71-b16d-49bc-b80b-42f92cd6aded", "name": "l(r:p1rdt6348lv-p1rlv13191)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d84ac329-f314-41be-a2ee-89bc74789a18"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f6d09e9-3592-4560-8626-0d7cb71ca56a"}}}], "length": {"value": 0.0217677, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "99adfcee-ce5d-4d2a-8a1e-e54a38a2c08d", "name": "l(r:p1rdt6348lv-p1rlv13195)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d84ac329-f314-41be-a2ee-89bc74789a18"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e3e10c6-6ce2-4efa-be50-80e8b9bffe29"}}}], "length": {"value": 0.0257734, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3912c661-e4ef-4616-8d05-3299ab44ff9e", "name": "l(r:p1rdt6348lv-p1rlv13201)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d84ac329-f314-41be-a2ee-89bc74789a18"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cdd7c49-e758-4009-8db5-d0b5748f919c"}}}], "length": {"value": 0.008488610000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3c1adb4d-4ff6-4c8a-8c1a-43251f741964", "name": "l(r:p1rdt6349lv-p1rlv13189)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdfa0310-7dc5-4181-a64e-cc2522370547"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "268361f6-d5ac-4002-80a6-f56f3b33599c"}}}], "length": {"value": 0.0123575, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "59797aff-2413-4c30-b02b-f1d86b4483ea", "name": "l(r:p1rdt6350lv-p1rlv13190)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0138b892-d18e-497c-9857-c4d5676deac2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3dbc593c-3949-4fa4-8738-d92540dbf998"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "5cf6510a-4dea-4772-ad91-0ea898f6570e", "name": "l(r:p1rdt6353lv-p1rlv13194)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "015322ae-7712-488f-9569-33fc785e4f62"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d5ba889-d8f7-44ca-86b2-40939fa95df2"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "3c73b898-fe34-4069-b66a-29eddd852722", "name": "l(r:p1rdm13558-p1rlv13196)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fd10fd1-b67f-422c-b976-582e2bb4e0ec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27013147-3d8f-4d75-a7a7-24457dc6d62a"}}}], "length": {"value": 0.0952802, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d43267bf-c60c-46cf-a3c3-40514c8ed391", "name": "l(r:p1rdm13558-p1rdt6354lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f06a08bd-05ea-4914-b0d0-07cd0e83bfbc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fd10fd1-b67f-422c-b976-582e2bb4e0ec"}}}], "length": {"value": 0.019710700000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b6dc79bc-04b3-4a9d-95f9-39133febe09b", "name": "l(r:p1rdm13559-p1rlv13200)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "786efaf4-c281-4def-9a4e-2ffbf37e08be"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fed30a3f-12a5-4545-b5d5-5c13a131a256"}}}], "length": {"value": 0.0781624, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "336fd466-42ce-4a03-a8b1-500c9b6320ff", "name": "l(r:p1rdm13559-p1rdt6354lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f06a08bd-05ea-4914-b0d0-07cd0e83bfbc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "786efaf4-c281-4def-9a4e-2ffbf37e08be"}}}], "length": {"value": 0.0196968, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3fb850f0-48fc-4d93-9b2f-53099e8c7a93", "name": "l(r:p1rdt6355lv-p1rlv13197)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1d14a79-4d18-43fe-8790-57ea9adf83a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b077d0f-74ec-4a04-8eb8-cf02ad16077d"}}}], "length": {"value": 0.00855264, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7445bde4-f85a-4868-beaa-c9eb3c64ae62", "name": "l(r:p1rdt6356lv-p1rlv13199)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "548724aa-110a-428f-b71a-acdf0051dc39"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad7545fb-8a41-4ed7-a178-e90f19bfa9d5"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "1b5cb726-1c52-4df2-8c39-dd309d7acca2", "name": "l(r:p1rdt6409lv-p1rlv13316)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e36cfaaa-3996-4cc6-aa4f-170f20c5d1e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473b080b-1412-40dc-a452-09d43a462098"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "9e896bae-73ca-433f-9ddc-b981c3e73cf1", "name": "l(r:p1rdt6498lv-p1rlv13597)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "353889fb-da44-4cf8-ae0e-d20541f36d7e"}}}], "length": {"value": 0.0114781, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8553403c-d26e-4b50-8608-cd168ebfbd94", "name": "l(r:p1rdt6498lv-p1rlv13631)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6015a810-79da-480f-b1a1-fd6a4abdba37"}}}], "length": {"value": 0.00314293, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "c01c83bb-3dbc-4882-b0f0-e842930869ba", "name": "l(r:p1rdt6498lv-p1rlv13696)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f92273c9-90b8-4819-b036-9d69afb5aed6"}}}], "length": {"value": 0.0270935, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1b049af0-8fb0-40ee-8c70-d2be4bee9165", "name": "l(r:p1rdt6498lv-p1rlv13702)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fe3c958-296f-4b51-8b2b-74bb34ddb5a6"}}}], "length": {"value": 0.0161535, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d15500ac-94ef-479c-a786-fdd84b84b87e", "name": "l(r:p1rdt6498lv-p1rlv13703)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9efacf5-5b96-4670-b6f1-dc398485cde9"}}}], "length": {"value": 0.0105519, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4fc94db9-da62-43ee-9583-c2c0fd98625c", "name": "l(r:p1rdt6498lv-p1rlv13724)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "457c6c9d-5020-4cf3-9c1e-c36012a619d2"}}}], "length": {"value": 0.0187626, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8091ae42-7ca0-4232-911a-682fa9fb74a3", "name": "l(r:p1rdm13996-p1rlv13598)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce39f1f5-b784-4919-9d3d-f6149f39595e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59953c2f-244e-4bb8-ab24-b28d82b195e1"}}}], "length": {"value": 0.0312105, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "01e418b1-0c88-4fa1-9b60-1516e6ba9401", "name": "l(r:p1rdm13996-p1rlv13626)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce39f1f5-b784-4919-9d3d-f6149f39595e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aeea20e0-9908-4f28-aa5d-068244e3861b"}}}], "length": {"value": 0.045519500000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "166332aa-67ba-485f-93b1-02469f1cdf58", "name": "l(r:p1rdm13996-p1rlv13635)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce39f1f5-b784-4919-9d3d-f6149f39595e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc33013a-6a90-46a7-9127-f32288111c14"}}}], "length": {"value": 0.0353648, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2b8702e0-0e6b-4594-a41c-501c6a9f441d", "name": "l(r:p1rdm13996-p1rlv20504)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce39f1f5-b784-4919-9d3d-f6149f39595e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b3e7495-7732-42ce-8d53-a5f1b7383ce4"}}}], "length": {"value": 0.0518247, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f092bdfa-1b2e-4449-91e0-4c62efc169e0", "name": "l(r:p1rdm13996-p1rdt6499lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb05d831-1556-4f56-8065-d9d16657caa3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce39f1f5-b784-4919-9d3d-f6149f39595e"}}}], "length": {"value": 0.0125057, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0581c111-e821-458c-a17c-100b3ff33c3a", "name": "l(r:p1rdm13999-p1rlv13698)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f85240e6-bbbe-4b90-8419-a00a3ca9613f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3839c291-3f45-46c3-973f-6a9615fcf81b"}}}], "length": {"value": 0.0426193, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "40b10f22-d50a-4135-8e84-81fa97145e9b", "name": "l(r:p1rdm14000-p1rlv13726)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea740eb8-42c6-4417-97d6-7c73f1fc2bc8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "642597e6-fe60-442f-b356-2be6f21677b2"}}}], "length": {"value": 0.00697416, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "072d74a7-35ce-499b-be52-d6ad80a0dc15", "name": "l(r:p1rdm13999-p1rdm14000)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f85240e6-bbbe-4b90-8419-a00a3ca9613f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea740eb8-42c6-4417-97d6-7c73f1fc2bc8"}}}], "length": {"value": 0.0139057, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5f658b70-1fd2-4e3d-ac5c-c7a295a50529", "name": "l(r:p1rdm13999-p1rdt6499lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb05d831-1556-4f56-8065-d9d16657caa3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f85240e6-bbbe-4b90-8419-a00a3ca9613f"}}}], "length": {"value": 0.0125149, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f76f9ba9-1ad5-411f-8fe0-e19d0b125427", "name": "l(r:p1rdt6500lv-p1rlv13613)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a20a4242-8a76-49f3-9bf5-3d7aaf751cdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "216537dd-ea7b-461c-b821-99491c41b7f0"}}}], "length": {"value": 0.0114283, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "ebf5f920-605f-4b2b-9361-25feec533c82", "name": "l(r:p1rdm14004-p1rlv13618)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83aa4266-e486-4e00-a09b-7bcdc613a9b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f823a90c-effd-489c-9e0a-c110ccb7b9e8"}}}], "length": {"value": 0.0123108, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "c92a290b-f056-49ba-b87b-2d53df6805ed", "name": "l(r:p1rdm14007-p1rlv13653)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff282b99-30bb-4c1d-acb9-02fafe241577"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c61a243-7736-46a0-a950-7cc811381158"}}}], "length": {"value": 0.0534886, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "a96b6494-0b33-4e6a-86cf-59557654a321", "name": "l(r:p1rdm14002-p1rlv13599)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c0ae3b1-ac0d-43c9-9a1e-c73bd10e3ad8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2a60818-4310-4100-9aa8-35ef37aa5f40"}}}], "length": {"value": 0.0432926, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "6d4b04c7-dd70-46da-9bc3-430fe1b50bb9", "name": "l(r:p1rdm14005-p1rlv13648)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d576dffc-af75-488e-8c51-19aa726f0505"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62a29ac5-7227-43b2-b602-b1189cc93839"}}}], "length": {"value": 0.0533671, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "6fe861c6-ef06-4253-98a7-6b8afb1cd014", "name": "l(r:p1rdm14002-p1rdm14005)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c0ae3b1-ac0d-43c9-9a1e-c73bd10e3ad8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d576dffc-af75-488e-8c51-19aa726f0505"}}}], "length": {"value": 0.00732814, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "b3bdf82d-ea8f-474c-92c9-d4b35eb23516", "name": "l(r:p1rdm14002-p1rdm14007)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff282b99-30bb-4c1d-acb9-02fafe241577"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c0ae3b1-ac0d-43c9-9a1e-c73bd10e3ad8"}}}], "length": {"value": 0.007327430000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "f5e00887-072c-477b-a27b-8a1bb5b644a1", "name": "l(r:p1rdm14004-p1rdm14007)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83aa4266-e486-4e00-a09b-7bcdc613a9b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff282b99-30bb-4c1d-acb9-02fafe241577"}}}], "length": {"value": 0.007320720000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "3c9c08f9-58e9-4367-aee8-72788caa6a7c"}}}}, {"uuid": "8653ff7a-8098-4538-800a-42481de0aacb", "name": "l(r:p1rdm14004-p1rdt6500lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a20a4242-8a76-49f3-9bf5-3d7aaf751cdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83aa4266-e486-4e00-a09b-7bcdc613a9b5"}}}], "length": {"value": 0.00898801, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "f731ee6a-9af9-40b1-a1a2-dadc871f741c", "name": "l(r:p1rdm14008-p1rlv13687)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e5abf33-75a2-446f-9c6c-1f3384b78c24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4671f981-e26e-4f26-9698-7f9068ce6dec"}}}], "length": {"value": 0.00688001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "c55b8ce0-a116-435e-81c7-4803d454bdde", "name": "l(r:p1rdm14009-p1rlv13719)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "592b8095-ba99-4993-a445-9af51fa89f57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44aa3f37-e0db-4050-b47f-ac14b7fa6534"}}}], "length": {"value": 0.00707054, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "1bfc33e4-b04b-4983-8901-3644068a4e2f", "name": "l(r:p1rdm14006-p1rlv13652)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33445b16-68bf-4606-8ac5-def4763fb95d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3310c14a-d1ee-4d0c-8428-d002703c61d5"}}}], "length": {"value": 0.00737761, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "55929b77-1dd1-4d96-8f47-b2896190c205", "name": "l(r:p1rdm14006-p1rdm14009)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "592b8095-ba99-4993-a445-9af51fa89f57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33445b16-68bf-4606-8ac5-def4763fb95d"}}}], "length": {"value": 0.00898801, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "195330b0-ed90-4511-a59e-4f29b3f0af24", "name": "l(r:p1rdm14008-p1rdm14009)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e5abf33-75a2-446f-9c6c-1f3384b78c24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "592b8095-ba99-4993-a445-9af51fa89f57"}}}], "length": {"value": 0.00898801, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "876bd333-5a47-4e8f-a9b1-cc4abcb2151a", "name": "l(r:p1rdm14008-p1rdt6500lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a20a4242-8a76-49f3-9bf5-3d7aaf751cdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e5abf33-75a2-446f-9c6c-1f3384b78c24"}}}], "length": {"value": 0.017982000000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "3c9c08f9-58e9-4367-aee8-72788caa6a7c"}}}}, {"uuid": "342ef8ad-e444-494e-ad4c-92901121506a", "name": "l(r:p1rdt6501lv-p1rlv13600)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59ab6d81-a91c-4350-8f94-abe02e3e1555"}}}], "length": {"value": 0.0222413, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "390e5cf1-b1e6-49ab-b980-6194c2f0c071", "name": "l(r:p1rdt6501lv-p1rlv13606)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29838633-5c95-4b73-8227-cfa7f4aedc32"}}}], "length": {"value": 0.0135771, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e9b80295-684b-4497-aeca-3ac73bfe04d1", "name": "l(r:p1rdt6501lv-p1rlv13608)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5e8caf4-4d81-4bbd-98df-6622c5ad0563"}}}], "length": {"value": 0.00679883, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5b4b52a4-31e7-4087-bb1e-24c7c491bf3e", "name": "l(r:p1rdt6501lv-p1rlv13619)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f693a1d2-5499-4810-9458-f205eda265fa"}}}], "length": {"value": 0.0334092, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "97e8fcf2-7304-40bf-ae9b-e7cdd37a4fb7"}}}}, {"uuid": "d453bf68-5c20-462a-8a81-469dded3c831", "name": "l(r:p1rdt6501lv-p1rlv13622)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4540b2cb-ee21-4515-a7ca-fbca371f060d"}}}], "length": {"value": 0.0312591, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c582d791-9861-4686-a34a-1a5ee46f781c", "name": "l(r:p1rdt6501lv-p1rlv13637)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30c470ac-39d1-4379-9ae7-790d912bce2c"}}}], "length": {"value": 0.0185945, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "99295cd8-2b7e-4cca-aa16-0b8d909f4c06", "name": "l(r:p1rdm14016-p1rlv13683)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b7d4c6f-98b5-4cec-b8a4-9311b5fc92bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "de45dc59-3e0a-4b33-8cf4-d5213b0140c1"}}}], "length": {"value": 0.0352211, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ca89eb81-8901-400a-9265-f885565a3423", "name": "l(r:p1rdm14016-p1rdt6501lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b7d4c6f-98b5-4cec-b8a4-9311b5fc92bd"}}}], "length": {"value": 0.0288269, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2db45833-0f3f-4f0f-837b-c37add7fd184", "name": "l(r:p1rdt6502lv-p1rlv13601)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7682e9f7-1272-4781-b128-34c7329afe49"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91953a27-bbc7-494a-bec2-a12b4c0f6af6"}}}], "length": {"value": 0.015644, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7c0d2bec-f934-477c-9124-d3536213c299", "name": "l(r:p1rdt6502lv-p1rlv13634)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7682e9f7-1272-4781-b128-34c7329afe49"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "987b05d5-9bb9-434d-98b3-623ee5014870"}}}], "length": {"value": 0.015644, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c18dbc35-bff3-4eed-8032-7a9d865d9cb8", "name": "l(r:p1rdt6505lv-p1rlv13604)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387e7785-8d40-4ddd-8c2b-14a83d4e7401"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9b83bdf-b564-4997-bfc7-1be2f2e58199"}}}], "length": {"value": 0.0220113, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "316eb2e4-da26-4004-9bc7-4f0f810b0c35", "name": "l(r:p1rdt6505lv-p1rlv13605)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387e7785-8d40-4ddd-8c2b-14a83d4e7401"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c39dc6f1-08b5-4bc1-a6ae-be0076af56aa"}}}], "length": {"value": 0.021993400000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c4d7cf80-30b7-49d5-bc93-a33daa9a50b4", "name": "l(r:p1rdt6505lv-p1rlv13654)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387e7785-8d40-4ddd-8c2b-14a83d4e7401"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7be734c-88e2-42c1-8061-f4632bd05759"}}}], "length": {"value": 0.0264068, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2fa21c7c-b71e-481c-8ba0-705b20e1dd84", "name": "l(r:p1rdt6505lv-p1rlv13676)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387e7785-8d40-4ddd-8c2b-14a83d4e7401"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8df1a69e-5b18-4eef-ab60-543a97257297"}}}], "length": {"value": 0.028008200000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4c9980ea-c901-4e92-bb89-6f907b3a5dca", "name": "l(r:p1rdt6505lv-p1rlv13715)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387e7785-8d40-4ddd-8c2b-14a83d4e7401"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a822fdb0-b531-49b0-89da-b517e5ae6e3a"}}}], "length": {"value": 0.00829409, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6c069c68-5c44-4ed0-b1cf-af99663412ef", "name": "l(r:p1rdt6507lv-p1rlv13610)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5844baa-5e0f-4edd-9122-fe4255adad0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17d92377-b4f1-4194-89cd-130bddb9b77c"}}}], "length": {"value": 0.0581195, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "89882ab7-3fbe-4a43-8813-4000db50953d", "name": "l(r:p1rdm14031-p1rlv13712)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a2f5fad-c0a9-4f62-a318-ef00c0d4f470"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ab8bce-7c02-4c7b-962e-3fb44a3ab7a9"}}}], "length": {"value": 0.0677651, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8f8439ca-eff8-40f9-aa8d-d359f0721d26", "name": "l(r:p1rdm14031-p1rdt6507lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5844baa-5e0f-4edd-9122-fe4255adad0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a2f5fad-c0a9-4f62-a318-ef00c0d4f470"}}}], "length": {"value": 0.0164067, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "efd01f17-490e-47c7-8d2e-568a421cec6a", "name": "l(r:p1rdt6508lv-p1rlv13611)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "630b2a63-622f-4f78-8390-77c69ba7e393"}}}], "length": {"value": 0.00515213, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5a1a2657-849d-4e13-8c0c-965a8a7ab30e", "name": "l(r:p1rdt6508lv-p1rlv13666)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5868c24b-2a58-459b-8650-a6072241aca8"}}}], "length": {"value": 0.006682040000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c45a4782-6379-4df5-896d-ba72b47ee680", "name": "l(r:p1rdt6508lv-p1rlv13685)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f777bc74-e6f3-4e80-bb72-0764964db21e"}}}], "length": {"value": 0.04116050000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "485ec2d2-baf3-4031-b775-f3a35c51e1f2", "name": "l(r:p1rdt6508lv-p1rlv13701)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa7a324e-d367-49a5-820a-b18e72243265"}}}], "length": {"value": 0.00980837, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "63ca6e20-b870-4ea1-aaea-7904c242ba8a", "name": "l(r:p1rdt6508lv-p1rlv13707)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "286623b3-af08-4a60-896a-1f5b85fe04a5"}}}], "length": {"value": 0.0432014, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4a2c57de-4589-43cc-8447-5abb34d130a0", "name": "l(r:p1rdm14033-p1rlv13651)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "572123ef-d255-42a9-9c61-95d99aaff775"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c808261e-a49e-4954-bdc4-a8b63d0ee25b"}}}], "length": {"value": 0.0148948, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d9124535-9f55-4e17-90ec-cf5341d9c500", "name": "l(r:p1rdm14033-p1rlv13728)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "572123ef-d255-42a9-9c61-95d99aaff775"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9657a993-0005-4ffc-8c9f-18e80a491070"}}}], "length": {"value": 0.00972322, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cc27c9f6-9b6e-4814-b9c7-7166cc2d1bed", "name": "l(r:p1rdm14033-p1rdt6508lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "572123ef-d255-42a9-9c61-95d99aaff775"}}}], "length": {"value": 0.0189224, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3162f10d-4158-469a-96cd-a51fa01fb20a", "name": "l(r:p1rdt6509lv-p1rlv13612)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f817a28f-c650-4eb4-84c0-751fe5053c75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6eda3e97-a618-41ab-ae55-ba67f6bb0234"}}}], "length": {"value": 0.00552959, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9d01a910-b603-4852-9d53-708297ee103a", "name": "l(r:p1rdt6509lv-p1rlv13628)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f817a28f-c650-4eb4-84c0-751fe5053c75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e47df44a-79f1-423b-a295-c9c354795895"}}}], "length": {"value": 0.0122449, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "516a46a4-a886-40b9-b1ea-e684b208f509", "name": "l(r:p1rdm14041-p1rlv13627)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b65a5fd-f38e-447a-a51a-e7a214ba6bcc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bd69c55-2141-4c8e-becf-efa4bff8a63e"}}}], "length": {"value": 0.0158712, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8cb36820-73d5-492e-8845-b9ec92e8fa18", "name": "l(r:p1rdm14041-p1rlv13659)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b65a5fd-f38e-447a-a51a-e7a214ba6bcc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "122e0772-7de6-4117-b1d3-caafbbbc8e22"}}}], "length": {"value": 0.009054330000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d8df7836-4789-448b-894e-7c1c617c95d9", "name": "l(r:p1rdm14041-p1rlv13660)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b65a5fd-f38e-447a-a51a-e7a214ba6bcc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3d6fd13-2f04-4f23-97a3-cdf99159174c"}}}], "length": {"value": 0.0113115, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "068f969c-0c98-4e0f-9524-1a21a3b8987d", "name": "l(r:p1rdm14041-p1rlv13677)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b65a5fd-f38e-447a-a51a-e7a214ba6bcc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9aa7e62-8974-4ef0-aa5a-bcd545245aea"}}}], "length": {"value": 0.0329272, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "65146649-1d08-42cb-af6c-acc8a012a05e", "name": "l(r:p1rdm14040-p1rlv13624)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1252c522-5ced-4f4c-908c-f58501ad6f92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a5746d1-24a6-4ae4-b5dc-cef23b56660d"}}}], "length": {"value": 0.00954632, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3ae44c1c-f5ef-4516-a648-5583d34cf7a6", "name": "l(r:p1rdm14040-p1rlv13721)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1252c522-5ced-4f4c-908c-f58501ad6f92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6097c903-70fc-4635-a66c-fee2243ba545"}}}], "length": {"value": 0.012462500000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "20173122-d8a7-4c92-a3b7-8ddb76680383", "name": "l(r:p1rdm14040-p1rdm14041)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b65a5fd-f38e-447a-a51a-e7a214ba6bcc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1252c522-5ced-4f4c-908c-f58501ad6f92"}}}], "length": {"value": 0.0125149, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "80fdbbc2-08c7-494f-bc26-6b81701d774b", "name": "l(r:p1rdm14041-p1rdt6509lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f817a28f-c650-4eb4-84c0-751fe5053c75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b65a5fd-f38e-447a-a51a-e7a214ba6bcc"}}}], "length": {"value": 0.0139057, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "52d0c8fb-a66f-4033-93f4-79e9ae946d79"}}}}, {"uuid": "c8f1e6a0-c36c-4ce6-99e7-ee182b295e7f", "name": "l(r:p1rdm14043-p1rlv13633)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9be8942c-8459-4c1d-a3b0-a89ee5cced4e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b3fe33f-fdcf-42f5-be08-8da15a4d4958"}}}], "length": {"value": 0.036068300000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "95e07a95-448b-4b98-80fa-457bcde4ecc4", "name": "l(r:p1rdm14043-p1rlv13663)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9be8942c-8459-4c1d-a3b0-a89ee5cced4e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54887ca7-ae23-42d0-a715-aed8baa38ade"}}}], "length": {"value": 0.0442205, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "17a54982-d8e3-4917-97dd-8e7dbe136d17", "name": "l(r:p1rdm14043-p1rlv13672)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9be8942c-8459-4c1d-a3b0-a89ee5cced4e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32bec8ad-b312-4502-a2a1-6a4c9b2dd87a"}}}], "length": {"value": 0.00371517, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "3e5beb3a-4808-431b-a276-401a1bc26c44", "name": "l(r:p1rdm14043-p1rlv13686)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9be8942c-8459-4c1d-a3b0-a89ee5cced4e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60fe0a16-aa4d-4fe8-9f39-81bfa13b505f"}}}], "length": {"value": 0.0111527, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9accb5a7-67c9-4b12-89a4-03446ebd99ee", "name": "l(r:p1rdm14043-p1rdt6509lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f817a28f-c650-4eb4-84c0-751fe5053c75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9be8942c-8459-4c1d-a3b0-a89ee5cced4e"}}}], "length": {"value": 0.0139057, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ca70462c-125c-4416-a604-f000d21623d6", "name": "l(r:p1rdt6510lv-p1rlv13614)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d62fe3b-7644-46d1-8a15-e86d95ae8b2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3de8b994-01ba-4eae-b9cf-7fb174d32355"}}}], "length": {"value": 0.01924, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bb7235ed-bd23-4bb0-99ce-00d534f6ceba", "name": "l(r:p1rdt6510lv-p1rlv13680)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d62fe3b-7644-46d1-8a15-e86d95ae8b2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85b910cd-def8-41d8-ad47-3c074a54ad8d"}}}], "length": {"value": 0.012694, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "52d0c8fb-a66f-4033-93f4-79e9ae946d79"}}}}, {"uuid": "84cbab40-20ee-4d00-86b9-42817ede7a15", "name": "l(r:p1rdt6510lv-p1rlv20467)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d62fe3b-7644-46d1-8a15-e86d95ae8b2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58e2b774-ac04-435e-9e03-573b3aa94cfb"}}}], "length": {"value": 0.00748899, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ff0d00c0-ac17-4823-ada8-ba030479f1ce", "name": "l(r:p1rdt6512lv-p1rlv13616)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "850d5b69-14cf-4a18-8cb0-4f1b3033b0aa"}}}], "length": {"value": 0.0125419, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2ab15224-388d-4616-8bd6-5a213b6945ec", "name": "l(r:p1rdt6512lv-p1rlv13643)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20009de0-cbe7-4b4f-a046-425a6ae71925"}}}], "length": {"value": 0.0106471, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9af93afe-5223-45fd-a014-1b40d134690d", "name": "l(r:p1rdt6512lv-p1rlv13646)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fe0466e-cce5-4c6c-b13f-cedd349b6944"}}}], "length": {"value": 0.00566202, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "023df541-8d16-46bf-b4d4-675baa72fc8a", "name": "l(r:p1rdt6512lv-p1rlv13650)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fa2041e-34c4-4f1f-a329-74969c3da75f"}}}], "length": {"value": 0.0342408, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "13f8ad6d-758e-44f8-8220-06aef0a4c41b", "name": "l(r:p1rdt6512lv-p1rlv13725)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e290046b-c936-4f51-b4ef-632bf572ab7f"}}}], "length": {"value": 0.0322281, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4947106f-8e2e-4805-b3b7-5e9672aadeac", "name": "l(r:p1rdm14062-p1rlv13664)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3ed4387-9ecb-43c4-a392-e72bc5cb32b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70cf02cc-8f1b-48ab-b9e6-50c3e58ad9ae"}}}], "length": {"value": 0.0332206, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "fe342819-1380-4393-a27d-ccc1439cd615", "name": "l(r:p1rdm14062-p1rlv13681)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3ed4387-9ecb-43c4-a392-e72bc5cb32b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60f08cde-51d3-4b51-9ab5-b61c8043950f"}}}], "length": {"value": 0.00918014, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "96b443e2-11df-4e89-981c-41c80cf02023", "name": "l(r:p1rdm14062-p1rlv13717)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3ed4387-9ecb-43c4-a392-e72bc5cb32b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdbfe616-f51f-416a-94ce-6e676d300226"}}}], "length": {"value": 0.00916206, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "488c4454-9ad4-484f-8d9c-aca4b7f2fd67", "name": "l(r:p1rdm14062-p1rlv20509)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3ed4387-9ecb-43c4-a392-e72bc5cb32b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fe37b51-0258-4812-9d96-3cc28c4bd55b"}}}], "length": {"value": 0.00548688, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "022d323e-07da-4138-8e8b-44b035820841", "name": "l(r:p1rdm14062-p1rdt6512lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3ed4387-9ecb-43c4-a392-e72bc5cb32b6"}}}], "length": {"value": 0.018909400000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e3150130-99fc-424b-93c8-da14b313e743", "name": "l(r:p1rdm14063-p1rlv13671)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "485928ba-ff70-4be2-89ff-721ff82269fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2f95b8b-190c-4df2-9dd2-daee5efde34b"}}}], "length": {"value": 0.0398564, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b6d97809-156e-4113-af17-e0200a96fbff", "name": "l(r:p1rdm14063-p1rlv13714)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "485928ba-ff70-4be2-89ff-721ff82269fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17936036-1191-4f91-bc12-2298db7b77e3"}}}], "length": {"value": 0.0397956, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e0a8749f-fc99-4c40-843a-c950cd6b3617", "name": "l(r:p1rdm14063-p1rdt6512lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "485928ba-ff70-4be2-89ff-721ff82269fb"}}}], "length": {"value": 0.0189224, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "033e3f67-3877-4ae0-b6ec-ed4ac02d0081", "name": "l(r:p1rdt6514lv-p1rlv13623)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad6bef77-8f39-43b4-b2d7-58aa6e45a60b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80f60ab3-722f-4765-8b91-4fd0196171d7"}}}], "length": {"value": 0.0879332, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4c3fb8e9-1d83-4791-8274-8e68fb1645a7", "name": "l(r:p1rdt6514lv-p1rlv13716)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad6bef77-8f39-43b4-b2d7-58aa6e45a60b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb3b4207-12ad-46e6-b4de-59149a46f8a1"}}}], "length": {"value": 0.107138, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b4624fcd-3303-45b7-aeab-e8182705ea7d", "name": "l(r:p1rdm14072-p1rlv13640)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "395dac73-8fae-4718-a28c-191a76a298f2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "653bdc0d-5b21-4640-861b-b88ddb5c651a"}}}], "length": {"value": 0.0819367, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c040ef88-e64c-4303-83fd-b18d037139ca", "name": "l(r:p1rdm14072-p1rdt6514lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad6bef77-8f39-43b4-b2d7-58aa6e45a60b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "395dac73-8fae-4718-a28c-191a76a298f2"}}}], "length": {"value": 0.0139057, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "caa8dcf0-ff72-42e0-b35b-3d850862220e", "name": "l(r:p1rdt6515lv-p1rlv13625)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b92f8bcd-91ce-42bd-be69-0b43cb9d4122"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c667408-52a0-4258-8e93-557c94520a1e"}}}], "length": {"value": 0.09092920000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "61b204a7-5100-4427-bab6-d2a4ff8ae7df", "name": "l(r:p1rdt6515lv-p1rlv19156)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b92f8bcd-91ce-42bd-be69-0b43cb9d4122"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7538ab85-10b4-4f60-98f8-179e954173b0"}}}], "length": {"value": 0.091396, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "c8be5034-7901-4e58-97e7-41c162aba1d0", "name": "l(r:p1rdt6515lv-p1rlv19163)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b92f8bcd-91ce-42bd-be69-0b43cb9d4122"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fed6fcd4-3c97-4f62-a1a7-0b66394218e1"}}}], "length": {"value": 0.0956659, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "6e8f9e3f-5286-4b5c-b948-13135572f5cc", "name": "l(r:p1rdt6515lv-p1rlv19165)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b92f8bcd-91ce-42bd-be69-0b43cb9d4122"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ebd10471-ab4c-4cb7-a822-a83ef20e9854"}}}], "length": {"value": 0.104528, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "188e1e24-abff-4778-add9-5cd6da283c9a", "name": "l(r:p1rdm14075-p1rlv13645)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2659bd3-f6ca-4d74-87c8-f92596986cb5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1acad56e-b6d6-4fa7-a925-f242c1558eef"}}}], "length": {"value": 0.0654705, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "3f25d6c2-6bb8-45d7-aefd-259a75c39fa3", "name": "l(r:p1rdm14075-p1rdt6515lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b92f8bcd-91ce-42bd-be69-0b43cb9d4122"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2659bd3-f6ca-4d74-87c8-f92596986cb5"}}}], "length": {"value": 0.00777706, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "7d73691e-3ace-4804-a2fc-b1e7bb2fc029", "name": "l(r:p1rdt6516lv-p1rlv13629)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "119a8559-8e6c-4314-9bbd-37ef3adde415"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b4358536-b06f-486d-b336-3a8576b428d0"}}}], "length": {"value": 0.0117712, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a9dc2406-fd4a-460a-b563-9f3869e7a46e", "name": "l(r:p1rdt6516lv-p1rlv13638)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "119a8559-8e6c-4314-9bbd-37ef3adde415"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db3908f7-94f5-43a7-a3de-1f6c9b72ebd4"}}}], "length": {"value": 0.009298230000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c42d401a-12f5-41aa-8978-0bab6fef0238", "name": "l(r:p1rdt6516lv-p1rlv13692)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "119a8559-8e6c-4314-9bbd-37ef3adde415"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "091b545a-eb31-4bea-a0a6-5aa9c7a8397f"}}}], "length": {"value": 0.022541900000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9ce6b824-e446-47d8-9b7f-8e6925a36c68", "name": "l(r:p1rdt6516lv-p1rlv13708)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "119a8559-8e6c-4314-9bbd-37ef3adde415"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a230534-6927-4af8-ba54-6ab4c9c32d21"}}}], "length": {"value": 0.020454, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "082fc58b-a217-4336-9a0d-065c229b7951", "name": "l(r:p1rdt6517lv-p1rlv13630)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5783bae9-2c74-473f-bf18-db40bc975409"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f474e4ba-6300-4014-afe9-c245e08cf3c5"}}}], "length": {"value": 0.0228311, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3c1f055c-199b-4923-bf89-d99e150d0252", "name": "l(r:p1rdm14084-p1rlv13641)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "822f96e6-61c5-455d-8a53-a494b49c9237"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eb10938-4b73-406c-bed4-0bd01e0bc20d"}}}], "length": {"value": 0.0127698, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "dfb21f10-33c3-41a3-a751-c1d7711c1c4f", "name": "l(r:p1rdm14084-p1rdt6517lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5783bae9-2c74-473f-bf18-db40bc975409"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "822f96e6-61c5-455d-8a53-a494b49c9237"}}}], "length": {"value": 0.0159549, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b10d847c-d604-4ede-9f26-ef7617eb21ce", "name": "l(r:p1rdt6518lv-p1rlv13647)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b16b03-1922-4aeb-8e70-d0e1387fbcab"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8753d37-07f1-45c6-a483-43cbfb6bf107"}}}], "length": {"value": 0.025624100000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "16c1caa6-a0ac-4132-a871-c1d589aa9772", "name": "l(r:p1rdm14085-p1rlv13632)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c597db56-a6af-472d-a7a2-e331175a2aae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b712121-d0c2-488a-9224-bea72928796f"}}}], "length": {"value": 0.028921, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "37be34c8-1e2b-49f9-8cb3-aa295a059daa", "name": "l(r:p1rdm14085-p1rdt6518lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b16b03-1922-4aeb-8e70-d0e1387fbcab"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c597db56-a6af-472d-a7a2-e331175a2aae"}}}], "length": {"value": 0.0331741, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "344cfb2a-35cd-4e8b-869a-9b28c99943fd", "name": "l(r:p1rdm14087-p1rlv20154)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180c5680-acd1-4988-ac36-1f351c3f9418"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02f2e50e-d42d-47d1-9274-d840042b64d1"}}}], "length": {"value": 0.0527706, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7ae66157-15aa-48f6-87af-00e3416e452b", "name": "l(r:p1rdm14087-p1rlv20161)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180c5680-acd1-4988-ac36-1f351c3f9418"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11a125b8-023c-4748-98a9-d74e9e0a7d23"}}}], "length": {"value": 0.04340720000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2f1e15b7-c811-40be-81ac-e05c3e936d83", "name": "l(r:p1rdm14087-p1rdt6518lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b16b03-1922-4aeb-8e70-d0e1387fbcab"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180c5680-acd1-4988-ac36-1f351c3f9418"}}}], "length": {"value": 0.0198942, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "228f74d1-87c0-4843-809b-e393c84a2239", "name": "l(r:p1rdt6519lv-p1rlv13636)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "606673ea-bcd2-459a-a0af-efb8b31c600c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4d3fe62-b327-4fc6-b2aa-795c9475019a"}}}], "length": {"value": 0.052177, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "167607d2-178f-4e8d-82c4-9bfd9975fab7", "name": "l(r:p1rdm14090-p1rlv13678)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e06b069-62f8-40c8-9abc-d4cc83937e41"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32b75c61-4e97-4e21-a786-8aab7a2d88f8"}}}], "length": {"value": 0.0759194, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "11760911-163e-44ae-af9b-fbbdf0f687b8", "name": "l(r:p1rdm14090-p1rdt6519lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "606673ea-bcd2-459a-a0af-efb8b31c600c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e06b069-62f8-40c8-9abc-d4cc83937e41"}}}], "length": {"value": 0.00898801, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "259929c5-0a19-4150-9cea-ff8dc5a0a7bd", "name": "l(r:p1rdt6520lv-p1rlv13639)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13c02cd3-cff3-4988-95b9-3993b9541427"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5484eab0-53a8-471c-92ec-29c11c08e740"}}}], "length": {"value": 0.0157099, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b03c2024-3c7a-4d2e-8e6e-7d42de59c0a2", "name": "l(r:p1rdt6520lv-p1rlv13669)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13c02cd3-cff3-4988-95b9-3993b9541427"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "607d3b54-2cea-476b-afe2-ea40c6c02ddc"}}}], "length": {"value": 0.00818072, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a2c154da-c79e-4d92-abad-f78947b543a8", "name": "l(r:p1rdm14092-p1rlv13662)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db3abe20-2ffb-4bf8-b425-5613701bd3f2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e55b944-ffad-47bf-8348-799afa4c7a1d"}}}], "length": {"value": 0.0117517, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2509fb4d-0dfc-4537-aac7-0cd0a6a4c808", "name": "l(r:p1rdm14096-p1rlv13679)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0c27b40-83a9-4938-bc12-a2ae57d5eafb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "284bbc5d-bb49-404d-823e-08ec543c90b8"}}}], "length": {"value": 0.0111879, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ad959039-7919-4664-bbfa-b8fc3bb04d8b", "name": "l(r:p1rdm14097-p1rlv13705)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb3a7829-4233-4af9-9679-08bd114bc00e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f409299-5ac0-4f31-a217-d0aef7fbc4d2"}}}], "length": {"value": 0.006644980000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f0c5ad2b-ab0c-47ff-996f-359b98a541c0", "name": "l(r:p1rdm14096-p1rdm14097)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0c27b40-83a9-4938-bc12-a2ae57d5eafb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb3a7829-4233-4af9-9679-08bd114bc00e"}}}], "length": {"value": 0.0158664, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "612c5150-f8fd-4503-afd5-72b168f3a3c8", "name": "l(r:p1rdm14092-p1rdm14096)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db3abe20-2ffb-4bf8-b425-5613701bd3f2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0c27b40-83a9-4938-bc12-a2ae57d5eafb"}}}], "length": {"value": 0.011940100000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "48f450bb-ff89-4556-9044-213f13d84df0", "name": "l(r:p1rdm14092-p1rdt6520lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13c02cd3-cff3-4988-95b9-3993b9541427"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db3abe20-2ffb-4bf8-b425-5613701bd3f2"}}}], "length": {"value": 0.0119317, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "2d347746-0969-4a8a-b986-c40ef4f4c015"}}}}, {"uuid": "83174978-498d-4a0c-9123-99b6f97be3f9", "name": "l(r:p1rdm14094-p1rlv13673)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a990c6c-4227-4896-8ea6-e92ce5360087"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9467d2d3-ad80-4bc7-aa9f-cd6e76494552"}}}], "length": {"value": 0.0209007, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d8400413-4b6f-448c-8b9f-35fd9343fb78", "name": "l(r:p1rdm14094-p1rlv13675)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a990c6c-4227-4896-8ea6-e92ce5360087"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c532e298-bdd5-416e-8ebe-a082489ffee6"}}}], "length": {"value": 0.023550600000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "47cee057-d034-469d-844a-fc4156ee7c4e", "name": "l(r:p1rdm14094-p1rdt6520lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13c02cd3-cff3-4988-95b9-3993b9541427"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a990c6c-4227-4896-8ea6-e92ce5360087"}}}], "length": {"value": 0.0125632, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fa38627e-ef06-43f8-96ec-98da2f37c21e", "name": "l(r:p1rdt6521lv-p1rlv13670)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0e4e42c-8dcd-47be-bfe8-b8b1eb4a5f24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce53d307-fc73-487a-8f6a-3a0e0787bf79"}}}], "length": {"value": 0.106379, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e0336142-b978-433d-8847-480a4107f3f4", "name": "l(r:p1rdt6521lv-p1rlv13694)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0e4e42c-8dcd-47be-bfe8-b8b1eb4a5f24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1de2ebf2-3207-4bf7-9702-4c729d99a6cf"}}}], "length": {"value": 0.07348910000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d686aa67-4e56-444b-b892-d06c1d8df229", "name": "l(r:p1rdt6521lv-p1rlv13695)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0e4e42c-8dcd-47be-bfe8-b8b1eb4a5f24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d73963d7-acf4-48b3-8e54-6ee9f403d36f"}}}], "length": {"value": 0.0966562, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ac3a550d-5246-49d8-ab21-eaaf8dd0a54a", "name": "l(r:p1rdm14098-p1rlv13642)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c12be3d4-719e-4567-91d9-c0ff24b783f1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "479d1486-ed05-44fa-8fab-64035623f267"}}}], "length": {"value": 0.0796353, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a1ad23ef-8d9b-43dd-9d37-af210c9edc45", "name": "l(r:p1rdm14098-p1rdt6521lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0e4e42c-8dcd-47be-bfe8-b8b1eb4a5f24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c12be3d4-719e-4567-91d9-c0ff24b783f1"}}}], "length": {"value": 0.0189224, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0e50b778-8db4-4046-9cbf-af628dd42567", "name": "l(r:p1rdm14100-p1rlv13682)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1db9a47a-f0ed-4141-b08e-f01a2ffd804f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a3c050c-cc0d-460e-af02-ce3421431474"}}}], "length": {"value": 0.0988767, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "26c24a09-ea79-4de4-86a7-17356670bdac", "name": "l(r:p1rdm14100-p1rdt6521lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0e4e42c-8dcd-47be-bfe8-b8b1eb4a5f24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1db9a47a-f0ed-4141-b08e-f01a2ffd804f"}}}], "length": {"value": 0.0189224, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fff836a7-3b7a-4332-8fa2-4ccc5047b40b", "name": "l(r:p1rdt6523lv-p1rlv13649)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66df2481-ae4f-4f39-aef4-7af09ce1a8fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43867e2f-79ee-4cec-bed3-0cad0727118c"}}}], "length": {"value": 0.053244900000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c912605f-1e8e-4af3-bc5a-fbd35d1f82bc", "name": "l(r:p1rdm14107-p1rlv13656)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2844042b-3f65-4a8b-8bab-56b42971e6ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8c0a04e-6e22-4da5-9907-7ae8097deb10"}}}], "length": {"value": 0.0192208, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "76751362-f6a1-47cf-a480-da419e869b1d", "name": "l(r:p1rdm14107-p1rlv13690)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2844042b-3f65-4a8b-8bab-56b42971e6ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "71c26ca3-0d61-46b8-a95b-710e0b760b62"}}}], "length": {"value": 0.0119597, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "8c4f49b2-3881-4901-9e2a-bdfedd44bb67", "name": "l(r:p1rdm14107-p1rdt6524lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ec2137a-f978-4808-a023-21f13464998b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2844042b-3f65-4a8b-8bab-56b42971e6ad"}}}], "length": {"value": 0.00891043, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "3f4222b7-7671-4abc-b6ee-713366959169", "name": "l(r:p1rdm14109-p1rlv13700)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2256f06d-59e9-4822-987f-7d26f40415c0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ecf9ee9-2a3c-431b-84c8-02c7c7aaacb1"}}}], "length": {"value": 0.0052345, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "b11a686c-caa0-43bc-9fc6-0c2a668d3c33", "name": "l(r:p1rdm14109-p1rdt6524lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ec2137a-f978-4808-a023-21f13464998b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2256f06d-59e9-4822-987f-7d26f40415c0"}}}], "length": {"value": 0.00891207, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "dac869e3-d445-4ffc-84be-6aab918f7e32", "name": "l(r:p1rdt6527lv-p1rlv13661)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8905812-7e3b-4875-87b5-da95999c5bb0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ef8e6ec-86d3-429c-89b4-6c7260701e70"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "2b6940c8-d947-4c87-a551-5c24bf4ffeb9", "name": "l(r:p1rdt6528lv-p1rlv13667)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d097d9be-dd3a-4616-a873-8ab5013c4e72"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d6cdd514-204d-4a86-b0f3-a9bc4990a2aa"}}}], "length": {"value": 0.0382292, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "3c9c08f9-58e9-4367-aee8-72788caa6a7c"}}}}, {"uuid": "c6f600b4-98d6-4e13-a8d6-9dc0d58ae55a", "name": "l(r:p1rdt6528lv-p1rlv13691)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d097d9be-dd3a-4616-a873-8ab5013c4e72"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "850df31b-ee95-4903-93b7-6e5911e8f8a0"}}}], "length": {"value": 0.0619169, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "feff346b-96b0-43c5-ae5a-f9eddc172f07", "name": "l(r:p1rdm14115-p1rlv13689)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b51fe8ae-f6d7-48c7-9f84-22fc7c1c1ba9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e5db11f-0418-4119-9c71-26619456fd7b"}}}], "length": {"value": 0.0409354, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "3c183149-1fd7-4707-9de8-d0a10af6da6f", "name": "l(r:p1rdm14115-p1rdt6528lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d097d9be-dd3a-4616-a873-8ab5013c4e72"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b51fe8ae-f6d7-48c7-9f84-22fc7c1c1ba9"}}}], "length": {"value": 0.00777706, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "67b7cc4c-7757-4d4e-8d9f-66ce36da8415", "name": "l(r:p1rdt6530lv-p1rlv13684)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4ee2d3a-e97c-4ec4-9fa0-d7db1b3e9253"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ec49353-14d1-4917-83bc-ca62cd94bf30"}}}], "length": {"value": 0.0531129, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8e8b88c6-aab7-4e5c-b8b9-c3c64a663429", "name": "l(r:p1rdt6531lv-p1rlv13693)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf4a2da0-682a-4119-b398-feaa6f5a8498"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5815b75-1226-4221-9bcb-bc75ce85fa17"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "ebaa7012-6c65-4b0d-908b-50ddad06d587", "name": "l(r:p1rdm14120-p1rlv13706)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75c95c35-ea3f-4958-9512-606f78de92b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e60fc98a-9c1d-4975-a9b9-e37271b4ac81"}}}], "length": {"value": 0.0324151, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "3c9c08f9-58e9-4367-aee8-72788caa6a7c"}}}}, {"uuid": "6d45312d-0cad-43fb-9bad-2ce0e6ad3c31", "name": "l(r:p1rdm14120-p1rdt6532lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0c3e71a-52a1-49b9-a899-c13d639ac0a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75c95c35-ea3f-4958-9512-606f78de92b5"}}}], "length": {"value": 0.00967577, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "3c9c08f9-58e9-4367-aee8-72788caa6a7c"}}}}, {"uuid": "e6ce21d6-2d77-4b8d-867a-87e52bca3ba4", "name": "l(r:p1rdm14121-p1rlv19151)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7194199d-e430-4b76-ae77-4c7f51477eed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e396aca-4116-40a0-8f17-bcd41f709ea5"}}}], "length": {"value": 0.0466133, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "9efd1997-d5b4-4e77-8930-a5f5597896ee", "name": "l(r:p1rdm14121-p1rdt6532lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0c3e71a-52a1-49b9-a899-c13d639ac0a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7194199d-e430-4b76-ae77-4c7f51477eed"}}}], "length": {"value": 0.00812092, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "c7be9070-30f3-4700-8c06-470b65f8f19f", "name": "l(r:p1rdt6535lv-p1rlv13711)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10f0e9fa-75b8-4eaa-a2ad-b6a3fb4ae859"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2bfaa34-267c-4dfd-8b6d-4ab444ac4048"}}}], "length": {"value": 0.0759779, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "f13c5842-49ff-4779-bdb6-34cd8e664711", "name": "l(r:p1rdt6536lv-p1rlv13713)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b93e7299-60a4-49d6-9d34-885860588861"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee766a99-bb6f-4d5c-8513-9d462103f6fc"}}}], "length": {"value": 0.00770954, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "858b6e8d-19a5-47af-b192-7fb99a49e5e2", "name": "l(r:p1rdt6536lv-p1rlv13723)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b93e7299-60a4-49d6-9d34-885860588861"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0f1846b-2515-48ef-9241-0276932f8e75"}}}], "length": {"value": 0.00908442, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "43e3456d-a787-4d4e-bad6-2710f05d6c28", "name": "l(r:p1rdm14127-p1rlv20478)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57ac4a24-2ddb-46c2-873d-c0b4f3e0600a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cd0effe0-d186-41a8-8197-24144fbc6218"}}}], "length": {"value": 0.0197863, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "4e91a915-48a9-4e23-8849-e14ae8fa716d", "name": "l(r:p1rdm14127-p1rdt6536lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b93e7299-60a4-49d6-9d34-885860588861"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57ac4a24-2ddb-46c2-873d-c0b4f3e0600a"}}}], "length": {"value": 0.00732814, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "9e793d61-64cc-44ff-b17b-fa7b43a1ec8f", "name": "l(r:p1rdt6539lv-p1rlv13727)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b34f50ff-9a1f-439e-81a8-dfcee658926b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36019623-eb62-412c-a591-41494980c9b7"}}}], "length": {"value": 0.0347798, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "68c65b63-27dd-4e30-9d5e-0bb769ae8388", "name": "l(r:p1rdt6539lv-p1rlv20450)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b34f50ff-9a1f-439e-81a8-dfcee658926b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "006c2753-37b3-4b59-82a6-8ce95f316e26"}}}], "length": {"value": 0.01495, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8b013ff2-c5d6-4080-83aa-2395a67efb7c", "name": "l(r:p1rdm14185-p1rlv13784)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36ab64e0-65cb-4515-9c06-4762a398672a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01a18948-75cf-4caf-951f-17a9c8d1f6bc"}}}], "length": {"value": 0.029367, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4c5e3312-2084-435a-bade-59ec2dae5db0", "name": "l(r:p1rdm14185-p1rdt6574lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a43920a-a200-40fe-b5b6-3cdba0c7e784"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36ab64e0-65cb-4515-9c06-4762a398672a"}}}], "length": {"value": 0.0286402, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2ecb58ca-d359-49c0-802f-611cc5587743", "name": "l(r:p1rdm14186-p1rlv13812)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f2b4d47-9668-4bcc-933b-1f422f423e3e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ffd737b-a273-4a6c-91c6-351b5719f658"}}}], "length": {"value": 0.011645100000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c1340aaa-b2e7-423c-a24c-4984fc6527d5", "name": "l(r:p1rdm14186-p1rdt6574lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a43920a-a200-40fe-b5b6-3cdba0c7e784"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f2b4d47-9668-4bcc-933b-1f422f423e3e"}}}], "length": {"value": 0.0169575, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "88709a42-68a3-404c-a28c-0c84626b3f70", "name": "l(r:p1rdt6581lv-p1rlv13797)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "608e485b-13ce-493b-be96-ab83ad733c92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65052833-aec9-4363-a0cf-4d70fa9bb0ce"}}}], "length": {"value": 0.0873919, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7a451c89-27b1-4961-b1d0-940b9033cd52", "name": "l(r:p1rdt6581lv-p1rlv13811)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "608e485b-13ce-493b-be96-ab83ad733c92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aef2ef8-706c-4316-be01-0707ddf0ac7c"}}}], "length": {"value": 0.06100800000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "93cc41fd-d6c5-4fe6-ae2e-4ba53376e452", "name": "l(r:p1rdm14205-p1rlv13792)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8b7c677-d0bf-47d0-8a2a-78417faa49b9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc5fcb56-435a-4a0d-b442-7489a98ad1cd"}}}], "length": {"value": 0.0873214, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ba97f8d3-dd14-4104-a0f9-e265a224b585", "name": "l(r:p1rdm14205-p1rlv13794)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8b7c677-d0bf-47d0-8a2a-78417faa49b9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9725b6c-5bac-456a-bb6a-ce16a5e6b1a5"}}}], "length": {"value": 0.0656609, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ac827c47-9381-4673-914b-eb251a3782c1", "name": "l(r:p1rdm14205-p1rlv13805)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8b7c677-d0bf-47d0-8a2a-78417faa49b9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83d60921-a1f2-4b9c-9709-d2be59b82db5"}}}], "length": {"value": 0.10165500000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "374da000-183c-490f-b8e4-90a747756774", "name": "l(r:p1rdm14205-p1rdt6581lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "608e485b-13ce-493b-be96-ab83ad733c92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8b7c677-d0bf-47d0-8a2a-78417faa49b9"}}}], "length": {"value": 0.0195453, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9b2db3aa-d79e-4506-8730-e7ec07f13f78", "name": "l(r:p1rdm14210-p1rlv19691)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "487eef02-df2d-47fe-a20b-ce1c23064495"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "604cb559-0f18-4ef7-8bcd-a07a7e7f96d7"}}}], "length": {"value": 0.0580592, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9845e9a8-a0e8-4ac8-b23f-43c8a5ec35c0", "name": "l(r:p1rdm14210-p1rdt6581lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "608e485b-13ce-493b-be96-ab83ad733c92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "487eef02-df2d-47fe-a20b-ce1c23064495"}}}], "length": {"value": 0.0390906, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c0b95dfe-dbb0-4b9d-aea3-888bbaae0e4d", "name": "l(r:p1rdt6847lv-p1rlv14434)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7b9897e-b820-424c-adf8-7416de585357"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06135bd7-6a77-4f04-a439-4ce8c245447d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "17c6ca6d-e99b-4b1e-b84a-cfdad5216da5", "name": "l(r:p1rdt6848lv-p1rlv14435)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94c9fa37-fc5c-4243-b0ca-f70840febaee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d07f5065-df41-484d-8e8a-80b2ff4e0e9b"}}}], "length": {"value": 0.012328000000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ed6ec446-d1e2-423b-95f6-3a2124d16714", "name": "l(r:p1rdt6848lv-p1rlv14436)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94c9fa37-fc5c-4243-b0ca-f70840febaee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad66e41a-88ab-443e-b10e-9e7b5b899119"}}}], "length": {"value": 0.012328000000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fab1734a-805a-45b3-bb29-8ec6cc98ff61", "name": "l(r:p1rdt6995lv-p1rlv14828)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09a476ff-48a0-4d27-9cf0-c007e2e98acb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9efa4c9-9832-4aa8-bf44-be0fe1e80cd5"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b55a7233-970e-4b46-bded-059f90e68dc0", "name": "l(r:p1rdt7015lv-p1rlv14908)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "536d7c56-85a6-4167-b4f6-2f39936cd662"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d73b0321-e181-4ecd-b431-9aa6985d56d0"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "72e2c700-4f3a-43a7-acef-5408f66d50aa", "name": "l(r:p1rdt7036lv-p1rlv14952)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a371c8b-1993-432c-b2c6-21b18bec27da"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3c39b0c-9c92-4934-876f-ee5f542f95cc"}}}], "length": {"value": 0.0147598, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d89a8c28-6964-4a2f-886e-cc984f5a7748", "name": "l(r:p1rdm15468-p1rlv15008)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "260ea1f0-7235-47fc-a576-3d647618290e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19231152-1fd1-4e07-a5d9-603c765b2cae"}}}], "length": {"value": 0.028564100000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b8d33ec2-8be0-4cba-8ff9-a32946eebaf4", "name": "l(r:p1rdm15468-p1rdt7036lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a371c8b-1993-432c-b2c6-21b18bec27da"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "260ea1f0-7235-47fc-a576-3d647618290e"}}}], "length": {"value": 0.0178658, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "97dfa04d-243a-4a4e-83a9-a041fdabcedc", "name": "l(r:p1rdt7038lv-p1rlv14954)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "046f6c53-8d9c-43a1-88ce-169ade9e9557"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9e128f5-eb18-44df-8ec4-35bd049ef630"}}}], "length": {"value": 0.00867639, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e3736839-7824-4b4e-aa1d-9cfd6a158fad", "name": "l(r:p1rdt7046lv-p1rlv14974)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cd6a9808-9889-4f16-825d-c9763357c293"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "884ff47e-8e20-4ae8-97bd-287d0ca9dc1b"}}}], "length": {"value": 0.010648, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "47d4754c-c9fb-4def-99b6-c75a6071c19d", "name": "l(r:p1rdt7054lv-p1rlv14992)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf93e681-3ab6-4929-95f1-1da6d5dd28fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4f8b1bc-83c3-4819-9d98-9491df98d494"}}}], "length": {"value": 0.0136862, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "212f4598-9e6d-4b92-a3d1-44610b4910f8", "name": "l(r:p1rdt7054lv-p1rlv15056)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf93e681-3ab6-4929-95f1-1da6d5dd28fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a914ec3a-4883-42a7-b25d-133a1410b8d9"}}}], "length": {"value": 0.0326989, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e190be67-e711-4051-bfd1-1e315ff72cb0", "name": "l(r:p1rdm15533-p1rlv15046)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25a6c92d-ea7f-4ede-af16-713ceedfc7b0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2182c9fd-fd3d-4cb1-b525-192480823e2f"}}}], "length": {"value": 0.0227649, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "37ac8bba-efa1-4bbc-bda6-22e4836756ce", "name": "l(r:p1rdm15533-p1rdt7054lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf93e681-3ab6-4929-95f1-1da6d5dd28fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25a6c92d-ea7f-4ede-af16-713ceedfc7b0"}}}], "length": {"value": 0.0107297, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2a79d577-2b03-4ef6-84e6-afb335adaea1", "name": "l(r:p1rdt7061lv-p1rlv15007)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc33ade7-4471-40b8-8e9b-1846e0ad60e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc29de5b-3a3f-40c0-bde4-9a57f5f62b5c"}}}], "length": {"value": 0.0316282, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "353ebd25-352a-4d04-9ead-4c6d9ddf80fc", "name": "l(r:p1rdm15583-p1rlv15027)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4445ca5-2fed-4352-ab78-66e072a4f482"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07e3b847-cc9a-4f84-bc00-cb4396b6dea0"}}}], "length": {"value": 0.0140589, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2559653c-404f-472f-89ab-b0aa2c33fe36", "name": "l(r:p1rdm15583-p1rdt7067lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ff878e1-3143-4f8e-aa92-74d0a9046417"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4445ca5-2fed-4352-ab78-66e072a4f482"}}}], "length": {"value": 0.06079190000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "257d6011-c8ae-4eed-b4c4-a349d68240c2", "name": "l(r:p1rdm15584-p1rlv15197)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ad4c131-0be7-46e5-8a32-5ff92552dfe6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80a74c6f-c9ec-4742-8fce-ad73c0a6c459"}}}], "length": {"value": 0.0228694, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d7e0b635-9e9d-4d19-b7fe-d028520488c2", "name": "l(r:p1rdm15584-p1rdt7067lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ff878e1-3143-4f8e-aa92-74d0a9046417"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ad4c131-0be7-46e5-8a32-5ff92552dfe6"}}}], "length": {"value": 0.0279022, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b6c37323-999f-4652-8438-a4e92ddec55f", "name": "l(r:p1rdt7069lv-p1rlv15045)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a1566f1-7f0d-41d7-adad-425c9a344eb0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "baccbdab-efc0-487d-b00d-38d3d4be57b4"}}}], "length": {"value": 0.08356350000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f4a62cdd-7ebe-4533-9ebe-30b2bc677c77", "name": "l(r:p1rdt7070lv-p1rlv15064)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "844bdc22-2e32-43ee-8e0b-26f3f4c107b8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "366c9c98-59f1-46d5-b39c-4046703e5e4b"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "a5acdfb1-a2f0-43f1-87c9-737ff5f1e24f", "name": "l(r:p1rdt7075lv-p1rlv15082)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e0577c2-8275-4303-ad11-2c4f56df3f5c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a56b9ad8-c53b-4652-bf94-a7a7dfb8b306"}}}], "length": {"value": 0.00723071, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "72eeb4f8-eec2-4e80-be4c-3ff5014734e2", "name": "l(r:p1rdt7080lv-p1rlv15109)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d86bd7f-7759-4d74-9c74-d58010498f92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "161d4e7b-30f2-447c-a369-1bfa3ba2cd70"}}}], "length": {"value": 0.0109809, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6dce47af-355e-492c-8ada-a69635288723", "name": "l(r:p1rdt7080lv-p1rlv15125)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d86bd7f-7759-4d74-9c74-d58010498f92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb6d8f13-f04e-4b80-a8dc-e16af1dc860e"}}}], "length": {"value": 0.0299076, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8cdd54a6-9f8d-4ee6-87ab-ae1b4d397431", "name": "l(r:p1rdt7087lv-p1rlv15163)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d0c96fe-78c2-4303-ac5c-bbe440f19666"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdee6d84-9253-4fba-b713-3e41d706e999"}}}], "length": {"value": 0.0407888, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "44e14507-623a-45b0-be7a-6186032730df", "name": "l(r:p1rdt7088lv-p1rlv15170)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f1652e8-6cf7-43d4-8474-e61a74873675"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d2f8fcb-c279-49d5-88be-39e6a1d1990b"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "d401fdd0-f323-47cf-9b6e-243c4816d543", "name": "l(r:p1rdt7089lv-p1rlv15171)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73cfcce9-a925-4f29-9cde-6dd6f50735e1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc7cd505-823c-49bb-9e49-3681267dbef0"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "6e104f67-822c-4dfe-821e-3d2270eaf935", "name": "l(r:p1rdt7090lv-p1rlv15180)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d6a4c80-d261-4350-8224-8fe5191459c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e218b01d-f713-4baf-9688-7e77ea413c8c"}}}], "length": {"value": 0.0031637000000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b937d1b0-3310-4bcf-9eec-ea96efd2c7d7", "name": "l(r:p1rdt7201lv-p1rlv15394)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6718b871-3967-4c29-83e5-441799c7fb92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd21ae8b-7841-43b4-871f-316c4b8b4cd2"}}}], "length": {"value": 0.0100846, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5875340a-352d-4b74-98dc-8883439cd675", "name": "l(r:p1rdt7201lv-p1rlv15399)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6718b871-3967-4c29-83e5-441799c7fb92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ec1f313-f341-498c-b1c2-6669b1cbc629"}}}], "length": {"value": 0.042765000000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "af21b504-5bae-4a97-84c8-ae9d4024e5de", "name": "l(r:p1rdt7201lv-p1rlv15419)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6718b871-3967-4c29-83e5-441799c7fb92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8bc46399-0276-4ae7-aa8b-4cdd3d3555e8"}}}], "length": {"value": 0.018884, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7be73f4f-717a-4cc3-883f-c8f78b45e694", "name": "l(r:p1rdt7201lv-p1rlv15478)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6718b871-3967-4c29-83e5-441799c7fb92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "335df4da-50d2-4fbe-a271-ac04257d35c7"}}}], "length": {"value": 0.031123500000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c680c5e9-2427-48d6-b643-b718a5387491", "name": "l(r:p1rdt7201lv-p1rlv15523)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6718b871-3967-4c29-83e5-441799c7fb92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37ccfa64-1373-49b2-85f6-279abea3c945"}}}], "length": {"value": 0.0693229, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ff3b35e7-9cbd-4064-b36f-4258d2d5cc0d", "name": "l(r:p1rdt7220lv-p1rlv15418)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d5e45d6-867a-4442-8258-2c04891dbc4b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9ca373a-b1c3-464d-bbe3-c05b728beb30"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "53336b97-0132-489e-86d2-5eec0f08b652", "name": "l(r:p1rdt7224lv-p1rlv15487)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d6a6156f-e72a-41f0-a307-e6030de24fde"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "921f8f54-ff83-4d2f-8bf4-ee80bab64ce8"}}}], "length": {"value": 0.0279743, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "907ce719-e56e-447c-b64f-d358a020f2fe", "name": "l(r:p1rdm15891-p1rlv15423)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79c5341b-3cd2-41a3-8bbf-e50857b00dae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26009a7e-9bfc-4967-af28-4d8937539eb1"}}}], "length": {"value": 0.027741000000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "393d7862-5b0a-4473-8ea7-c88cb9850068", "name": "l(r:p1rdm15891-p1rlv15474)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79c5341b-3cd2-41a3-8bbf-e50857b00dae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34e0ffc2-da17-441b-bd4d-26d5a1104712"}}}], "length": {"value": 0.0128476, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c8ea9ba6-341b-45bd-b369-354bb85e916f", "name": "l(r:p1rdm15891-p1rdt7224lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d6a6156f-e72a-41f0-a307-e6030de24fde"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79c5341b-3cd2-41a3-8bbf-e50857b00dae"}}}], "length": {"value": 0.0173084, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c4bc4441-c550-4b03-b0a0-efd60aadab66", "name": "l(r:p1rdt7248lv-p1rlv15466)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2087cee5-9f6e-4400-8ca8-bbb120cd4dae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "544be417-0db6-45a7-8314-ec40944781fa"}}}], "length": {"value": 0.00486903, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "15f7249a-14e6-4e3e-b936-42cf2e976a8b", "name": "l(r:p1rdt7248lv-p1rlv15483)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2087cee5-9f6e-4400-8ca8-bbb120cd4dae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c4e3eac-0b1a-4feb-b39f-079c6d2c1d82"}}}], "length": {"value": 0.0134294, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "04240cde-fe5e-4ae9-98d1-50fa051dd3c0", "name": "l(r:p1rdt7248lv-p1rlv15488)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2087cee5-9f6e-4400-8ca8-bbb120cd4dae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6579cc93-2b08-4010-816d-3bef509000cd"}}}], "length": {"value": 0.0434873, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2566c35a-0bf0-403c-be22-cd9edfb06e03", "name": "l(r:p1rdt7248lv-p1rlv15542)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2087cee5-9f6e-4400-8ca8-bbb120cd4dae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b09822b3-a220-48ff-ad4f-62fca602f8b6"}}}], "length": {"value": 0.0301654, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ee4e3654-f1a1-4d89-8f99-33119ceee479", "name": "l(r:p1rdt7253lv-p1rlv15484)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b4f7df4-5453-459d-8599-48fd5f29a9c6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6749066f-4739-41ec-8369-8da49dd9e1c8"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "42542b12-3e8e-4532-8026-92a216e7df40", "name": "l(r:p1rdt7268lv-p1rlv15525)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1130272e-b98e-496f-aeb9-c094cf9cd824"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6eec860d-08cf-4690-93e6-d909429d363d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "34b56bb4-acd5-442f-98dd-ae6a6000c99a", "name": "l(r:p1rdt7298lv-p1rlv15603)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d304e5e0-2cc1-4167-9fad-6fc72228d828"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "688da57a-6f10-4ef8-8763-202a88c3a495"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b91e6094-8b96-4b15-affe-53e4ab5b4c33", "name": "l(r:p1rdt7301lv-p1rlv15606)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43df4c14-a198-4d51-87f4-80000198cd47"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c32ce070-e690-4fc1-92ac-f857691de578"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "03539cf6-cfd1-4610-938a-815b5e0a0d89", "name": "l(r:p1rdt7302lv-p1rlv15607)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e2a141f-436a-45c0-9c15-179301a439c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32291502-d7be-4b45-8af7-cb217448e73f"}}}], "length": {"value": 0.0250222, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5e2c78d8-d1ca-458b-b93a-19d040944540", "name": "l(r:p1rdt7302lv-p1rlv15638)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e2a141f-436a-45c0-9c15-179301a439c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2715a637-d6f0-4e7b-b43e-20836bf4e614"}}}], "length": {"value": 0.0170411, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "114bfef7-5a42-4ad7-9635-b2c6241c80ff", "name": "l(r:p1rdt7306lv-p1rlv15614)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0926064a-1c87-450a-b282-23708de8aec4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ab2d6dc-f5bb-4320-86f3-bf08bb7cf93f"}}}], "length": {"value": 0.0921771, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "78f8538c-a644-4746-acd7-376a89bed97f", "name": "l(r:p1rdt7307lv-p1rlv15617)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ce9dd2c-9e17-46b7-a6f4-e85077664432"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6106bbe7-7a47-4c50-8b2a-d46d7432bccf"}}}], "length": {"value": 0.0103904, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "001dcfc9-4762-41f3-a424-9dcf9b505aca", "name": "l(r:p1rdt7307lv-p1rlv19146)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ce9dd2c-9e17-46b7-a6f4-e85077664432"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0bb184ad-cb26-4317-8c40-f2c8a9f80dab"}}}], "length": {"value": 0.0154412, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "653186ed-25f7-4a39-a24e-19bebabe5ff2", "name": "l(r:p1rdt7307lv-p1rlv19147)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ce9dd2c-9e17-46b7-a6f4-e85077664432"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "546433b3-d70e-49ed-9037-ec88adda79b9"}}}], "length": {"value": 0.0170949, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9cd99dc2-42f9-42a3-a539-3e46d435271c", "name": "l(r:p1rdt7311lv-p1rlv15622)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2d6046b-9ece-4295-a180-41bf2ce47ce6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1151b559-3ae0-4863-9363-9b395bbfc403"}}}], "length": {"value": 0.0755258, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "851d4bfa-61f2-4b83-92e2-03d2d1598df4", "name": "l(r:p1rdt7314lv-p1rlv15629)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97844fdb-b016-4ca3-8777-b0553ead9297"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec0bca53-a58b-4004-8dba-8defca9db4c7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "22a94b20-8087-46c1-8f36-29081323b267", "name": "l(r:p1rdt7318lv-p1rlv15634)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22b1ecce-d5df-4f42-abb2-9f4c3d3a28c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5af6dae-d20f-4a31-9544-b9455cd639bd"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "2c8762b9-a727-48e6-8626-8b0691e21672", "name": "l(r:p1rdt7550lv-p1rlv16114)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58be5cbe-5a7c-4fa5-972d-e03100b3bb46"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5984e209-9f0e-4844-91e6-902c8329f13c"}}}], "length": {"value": 0.010568, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "eb9dc53f-9107-4f64-8499-6dcf08b592a2", "name": "l(r:p1rdt7550lv-p1rlv16178)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58be5cbe-5a7c-4fa5-972d-e03100b3bb46"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "807b0bef-0d34-44a9-a2a9-0c0a11f4ea8e"}}}], "length": {"value": 0.010568, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7c32c8d6-dd37-4fda-9b4f-cefafc028e7d", "name": "l(r:p1rdt7551lv-p1rlv16115)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c4d7ee3-fc5d-4a17-a717-3d6b6d5a67ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52d1b79d-5c6b-4b44-9998-600c6debd999"}}}], "length": {"value": 0.0259188, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3b54588d-c6e8-4042-a694-8f87967ab8fa", "name": "l(r:p1rdt7551lv-p1rlv16157)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c4d7ee3-fc5d-4a17-a717-3d6b6d5a67ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6efff4f7-c67b-4cfb-a72d-30b6616825b1"}}}], "length": {"value": 0.0259188, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b929915f-3f5c-4a02-a605-4d4873b39119", "name": "l(r:p1rdt7552lv-p1rlv16116)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f5d6708-cef4-4aac-9fa0-c738953c788f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "972f8088-b67b-47d0-a86f-49179dfb1c92"}}}], "length": {"value": 0.0159262, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c71cbb71-235a-44d4-b728-c68916a4acd2", "name": "l(r:p1rdt7552lv-p1rlv16197)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f5d6708-cef4-4aac-9fa0-c738953c788f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "92a37082-36d4-4eca-95e4-88dbcacd6db5"}}}], "length": {"value": 0.0159262, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ec088b7a-ade2-41ea-864c-57e6fd14b91d", "name": "l(r:p1rdt7553lv-p1rlv16117)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7a672b2-d127-4fb5-8cc4-8115b8ef3f60"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "204899ec-81e4-4a72-bf70-69b3428a49a1"}}}], "length": {"value": 0.0305725, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a08734c0-f8c0-4514-bd5a-0a14ae6698f8", "name": "l(r:p1rdt7554lv-p1rlv16118)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86a6d184-d883-4e27-aee5-b89c82163284"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bca0b3a0-d4cb-4a4a-9b14-aa23d9e5e5fe"}}}], "length": {"value": 0.0431821, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "104b928d-0e37-4538-86e0-e3ce3f7cc27b", "name": "l(r:p1rdt7554lv-p1rlv16139)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86a6d184-d883-4e27-aee5-b89c82163284"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c840cf3f-be15-448b-8c03-8942c586b135"}}}], "length": {"value": 0.0529135, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "abbad3a6-93e2-42c7-a931-18251d488605", "name": "l(r:p1rdt7554lv-p1rlv16201)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86a6d184-d883-4e27-aee5-b89c82163284"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68aa5cc5-f6bf-4417-8653-747c56b37b5e"}}}], "length": {"value": 0.0637427, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f7fbf2cc-e76a-457d-ae93-ed19e5ec96f4", "name": "l(r:p1rdt7554lv-p1rlv16209)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86a6d184-d883-4e27-aee5-b89c82163284"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf413742-18c8-483d-b8f1-f125f95323da"}}}], "length": {"value": 0.0332888, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "da4e7bb9-ac02-48a7-8773-f803a9aa7a98", "name": "l(r:p1rdt7555lv-p1rlv16119)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0de9c581-b78b-44d6-8693-59b995e2a3bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0d6e608-d5bf-40d6-9efd-f3b0922e7d77"}}}], "length": {"value": 0.0197555, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "55ec2ab9-796c-472c-8a9d-64fbe049e120", "name": "l(r:p1rdt7559lv-p1rlv16124)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b593ec6-e1e3-48c2-b352-f7966f206aa9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6da4b2d0-66c7-43fb-9aab-3bbac03aa989"}}}], "length": {"value": 0.04179700000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a4d01ff6-e324-423e-8097-8fe2dde83c0c", "name": "l(r:p1rdt7561lv-p1rlv16126)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05e30abd-3c40-4dbd-9261-ca8a8abd9c56"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd41f55a-4b5d-4c19-9787-801072b3b946"}}}], "length": {"value": 0.014319000000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "54c5bc8b-b799-4216-ab3d-e01ebf98fd85", "name": "l(r:p1rdt7561lv-p1rlv16133)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05e30abd-3c40-4dbd-9261-ca8a8abd9c56"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "102b9460-ea9a-4099-b16f-40b8fdf99ef7"}}}], "length": {"value": 0.024141, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "08cb3840-ba64-4648-ac83-a9a0a208e7ba", "name": "l(r:p1rdt7564lv-p1rlv16135)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7588b3b-f54c-483d-b354-b9908483019a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "676de1a3-2dfd-4faa-a057-7739e825d136"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "eb5f1aa9-9ff8-40fd-8116-08d5bd2f5b05", "name": "l(r:p1rdt7570lv-p1rlv16146)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2b3b9e1-3d98-44c1-bd38-9325623a1553"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6d21c357-1033-45e1-84a0-b82ceafe6ab8"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "7d8cd8ac-49ed-4d0d-80aa-a56a0a98e204", "name": "l(r:p1rdt7572lv-p1rlv16149)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69bf048e-54cd-4e41-a23e-485b0cd98fae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b15792ca-a6bd-47e5-8c67-5c3076174848"}}}], "length": {"value": 0.0827433, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f9ca3f6b-08b6-438b-9f86-993d7fa5dd9e", "name": "l(r:p1rdt7572lv-p1rlv16200)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69bf048e-54cd-4e41-a23e-485b0cd98fae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1aacea55-115d-46c3-9590-725cf5040f38"}}}], "length": {"value": 0.0976866, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a44b7dcd-89ab-4bca-aa5d-4fbe0e9b4b31", "name": "l(r:p1rdm16630-p1rlv16158)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33a848c7-076e-4025-863b-ce9151bcc3ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b85e180a-8eb4-4acc-a816-d99758cc16ea"}}}], "length": {"value": 0.0621197, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c4c0ee7e-a839-4490-b368-ac306b9905e2", "name": "l(r:p1rdm16630-p1rdt7572lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69bf048e-54cd-4e41-a23e-485b0cd98fae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33a848c7-076e-4025-863b-ce9151bcc3ac"}}}], "length": {"value": 0.0168609, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ffb75304-be2a-4021-9df7-22035d0c632a", "name": "l(r:p1rdt7574lv-p1rlv16156)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a742708-0f8b-42d0-a977-b5ce5e36a042"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "74edd9e9-24a5-4b36-8ca8-24ef2fa3e972"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "c9189682-4127-4793-8dde-134bd7a7291f", "name": "l(r:p1rdt7576lv-p1rlv16168)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56b05024-7907-458d-a5c3-0e54ffbabdb5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fb5abb7-dd79-49aa-9185-88a90bb45bc7"}}}], "length": {"value": 0.0685246, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4d947146-90b2-45ec-bc1d-69b52e20c50d", "name": "l(r:p1rdt7579lv-p1rlv16177)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d00b7fe-0384-4c12-a0cf-8895458d3b80"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbbe8401-53a1-4ce7-9ce1-02f547055d95"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "e1f41f9d-38bc-4e6e-be1e-8944e4b9739e", "name": "l(r:p1rdt7588lv-p1rlv16206)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abc940b0-c9f5-4582-adaf-ad7f4a79a35f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ca42395-8d67-4e83-80ec-159cacb490f8"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "607adf52-d8db-4ffb-af17-e06b4b4fbc79", "name": "l(r:p1rdt7589lv-p1rlv16210)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53e9cf92-1c91-428f-bdff-64257257ad5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fd05f3c-df77-45bc-8686-458b681a3d08"}}}], "length": {"value": 0.0134298, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a5726d13-5f87-414f-b712-c0bdc1ced439", "name": "l(r:p1rdt7589lv-p1rlv16235)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53e9cf92-1c91-428f-bdff-64257257ad5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56b91b3f-dfdd-41bf-9d2e-a8183077c752"}}}], "length": {"value": 0.0134298, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "83719399-628f-43ed-9d51-afa6375509c4", "name": "l(r:p1rdt7598lv-p1rlv16221)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff1e0d26-d845-43c3-9aaf-01d1c007b9a1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9761003-33fa-482a-967b-b508ab67c19f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "28e30c05-116b-48f0-b762-f119ac7be7c2", "name": "l(r:p1rdt7599lv-p1rlv16222)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d838502-3769-4d70-839b-26fd628ce478"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4809afc1-2d3d-491d-80e5-9cd4e8da08f2"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "5b38ef2e-a672-495a-8c15-b228d75558b7", "name": "l(r:p1rdt7605lv-p1rlv16228)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3488ff0-696f-4180-bc70-41ff37f9c365"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8767650-39c5-4d4a-80ce-af408c246599"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "ec9d0c28-58f8-4219-86b8-4d3fe6dc4315", "name": "l(r:p1rdt7612lv-p1rlv16239)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fdfea70-187a-4bbc-ba3f-69cb74c4d5c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9642fa30-e5f7-42f1-8fda-ab75a265d25a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "ea4ba13f-ec5f-47ae-a475-1ff409bfad77", "name": "l(r:p1rdt7615lv-p1rlv16242)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "269e9ba5-bc54-4cbd-9140-4b1bea74fc53"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e82036d9-e6c8-42c3-b45b-30bef6902bbc"}}}], "length": {"value": 0.0438853, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "66f3614c-b762-431c-bba3-5445c8ac5bc5", "name": "l(r:p1rdt7615lv-p1rlv16261)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "269e9ba5-bc54-4cbd-9140-4b1bea74fc53"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "978533ca-ef57-4cb6-9e7f-b3c6d1bbd7d5"}}}], "length": {"value": 0.0039062, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "65534143-6fae-4784-bacd-558a8b721a34", "name": "l(r:p1rdm16694-p1rlv16253)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65458dd3-50e0-48d3-a0db-0015707d3cea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "268549c6-0c8b-44ac-b933-316b36645366"}}}], "length": {"value": 0.00713936, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "33912f3d-e42a-475f-8eb4-4cf6ed16c0e4", "name": "l(r:p1rdm16694-p1rdt7616lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6af13868-ecb1-4110-be3f-537741287035"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65458dd3-50e0-48d3-a0db-0015707d3cea"}}}], "length": {"value": 0.04559330000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1e096ee0-46cf-48e0-a5c7-6ea777f3864e", "name": "l(r:p1rdm16695-p1rlv16270)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83d31d7a-8900-4f2e-9183-8a10f07e2bdd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c620d4b9-a849-4bf6-b108-118836866602"}}}], "length": {"value": 0.00252406, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "fe55db9e-e385-467e-b205-95aee0e835b4", "name": "l(r:p1rdm16693-p1rlv16243)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "766647d4-7c3c-4058-b30c-dbc593b88ecb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20818cc7-617e-4ab7-8f7c-31eea6496a02"}}}], "length": {"value": 0.00264008, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "80ef82e9-89e1-4cdc-96a2-6fa1ad7525c5", "name": "l(r:p1rdm16693-p1rdm16695)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83d31d7a-8900-4f2e-9183-8a10f07e2bdd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "766647d4-7c3c-4058-b30c-dbc593b88ecb"}}}], "length": {"value": 0.0423278, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "cfe5162e-a033-4a41-818f-eae382c104ad", "name": "l(r:p1rdm16695-p1rdt7616lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6af13868-ecb1-4110-be3f-537741287035"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83d31d7a-8900-4f2e-9183-8a10f07e2bdd"}}}], "length": {"value": 0.0158248, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "2d347746-0969-4a8a-b986-c40ef4f4c015"}}}}, {"uuid": "81f9870b-57d8-46dd-8268-9ddfab130818", "name": "l(r:p1rdt7617lv-p1rlv16244)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4be4af94-fee7-40d6-9061-9a0fe0e7377e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0164339-acc1-4b95-aa31-3af42cf943f7"}}}], "length": {"value": 0.0112872, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "713a3da4-b5d5-4fbf-98a9-8452a1617c74", "name": "l(r:p1rdm16697-p1rlv16255)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d1fb8eb-57aa-4366-afe5-b79174f3a4c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04647fad-19dc-4ed8-8820-aa312674145c"}}}], "length": {"value": 0.0169738, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c2ff74fe-7d8e-4aeb-8e9c-f1f0a2cb7fde", "name": "l(r:p1rdm16697-p1rdt7617lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4be4af94-fee7-40d6-9061-9a0fe0e7377e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d1fb8eb-57aa-4366-afe5-b79174f3a4c7"}}}], "length": {"value": 0.0068104, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bac616b7-1504-4880-87c4-0dbc21ee3814", "name": "l(r:p1rdm16699-p1rlv16252)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "795f4296-7c54-4e96-8468-52903af39708"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5c6a5f39-0654-4e73-8050-c6c4ad9d54e6"}}}], "length": {"value": 0.0353234, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e02a1459-a30a-43eb-9142-957ff82ef685", "name": "l(r:p1rdm16698-p1rlv16245)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acb015a8-a9f8-492b-ab3f-b107bd956f91"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3783c838-b72e-42cd-8b0b-3005bca3cf5e"}}}], "length": {"value": 0.0114502, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "47db165b-0d9a-4146-8789-b79d73c2dd6c", "name": "l(r:p1rdm16698-p1rdm16699)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "795f4296-7c54-4e96-8468-52903af39708"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acb015a8-a9f8-492b-ab3f-b107bd956f91"}}}], "length": {"value": 0.0170042, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ea0f86b2-7d46-447e-afb9-c85eb9d4acac", "name": "l(r:p1rdm16699-p1rdt7618lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49f37435-54fc-42b4-baba-94f0611c8c76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "795f4296-7c54-4e96-8468-52903af39708"}}}], "length": {"value": 0.0170124, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f5a0982c-76ee-4c76-b17b-db2b29132c0a", "name": "l(r:p1rdm16700-p1rlv16267)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73030a97-0574-4802-80d1-14fefeafa63a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19aeb510-ac0e-4279-8db0-8de282beccc8"}}}], "length": {"value": 0.0129138, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ab960f3a-b750-4490-8919-1b78f1ee81f9", "name": "l(r:p1rdm16700-p1rdt7618lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49f37435-54fc-42b4-baba-94f0611c8c76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73030a97-0574-4802-80d1-14fefeafa63a"}}}], "length": {"value": 0.0510234, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "aef758c3-6056-49d2-8a02-60b50c63bd6e", "name": "l(r:p1rdt7619lv-p1rlv16246)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a205379-48f9-444c-baf8-dc84fc9c6d8a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd2dc2db-787a-4732-bae4-01186082a92d"}}}], "length": {"value": 0.0487659, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1ba0dfcc-9d4f-4d9d-9b25-d4ac783d610a", "name": "l(r:p1rdt7620lv-p1rlv16247)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af91c50-929d-4ac6-9272-7c44d17a0094"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8d5e9b7-dc95-41f9-8547-99d5e2eba874"}}}], "length": {"value": 0.029204400000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9a074422-3751-46be-a791-1c5831090b87", "name": "l(r:p1rdt7621lv-p1rlv16248)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60f0bddf-6e4b-495c-a98d-f3940d69a5e9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "feb24768-feab-40f0-acc3-0b2bb500133a"}}}], "length": {"value": 0.0226951, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8c4067c2-4a24-4294-b0b5-9e078686ce14", "name": "l(r:p1rdt7624lv-p1rlv16256)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e2075fb-9691-447e-9a73-f88649310bc1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32a9302f-2d40-4c2a-bde9-e4039694fed7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "0179bbe7-ed91-420f-bc7e-556355621ed5", "name": "l(r:p1rdt7625lv-p1rlv16257)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6b1e3b6-ce3a-4ad6-a046-6608530b2ec2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "935c99a6-bef6-4417-872c-0685011c440c"}}}], "length": {"value": 0.08197240000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b7d74205-f9f2-4629-b005-d28349a3ee52", "name": "l(r:p1rdt7626lv-p1rlv16260)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56f8eed1-77ae-4d65-80aa-7ae148350333"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdf35585-e2b3-4463-a6a8-acb352f25003"}}}], "length": {"value": 0.0157324, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "faadfdae-2d72-4662-91e7-ec1f7654ef6b", "name": "l(r:p1rdt7626lv-p1rlv16269)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56f8eed1-77ae-4d65-80aa-7ae148350333"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc746539-662a-4fe4-8774-6ba2dc538118"}}}], "length": {"value": 0.00987847, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5edfcfe0-2c44-4832-938e-e09b4621e7c1", "name": "l(r:p1rdt7627lv-p1rlv16262)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90d8891c-6e6d-46b9-8f88-acc9453c6541"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2797febc-f5e7-4cb3-b26f-ace990dc6920"}}}], "length": {"value": 0.00420024, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "18404b85-1ac1-4964-b5a4-69db35c99ef9", "name": "l(r:p1rdt7630lv-p1rlv16266)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ad2599f-313b-49c6-abaa-19177e1a9edc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8835446-b333-4be9-96bd-57ff9d01ebd3"}}}], "length": {"value": 0.0649914, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9c3cc8d2-c149-4fa9-8e26-1cfb3d5840fe", "name": "l(r:p1rdt7631lv-p1rlv16268)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4861056b-b634-4900-94bb-d6c995387351"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba6ebe7f-b6b9-4f89-8bbf-7bffd63e10ef"}}}], "length": {"value": 0.0412806, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "fe7937ea-1d97-4b06-ae00-05043b6f5450", "name": "l(r:p1rdt7699lv-p1rlv16416)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bfa76dc8-4007-4e52-9692-2eec7cb574e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f58421d6-268b-417f-a579-c9c51d010697"}}}], "length": {"value": 0.079141, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e329d231-586c-4da4-be1c-635869501cb7", "name": "l(r:p1rdm16862-p1rlv16395)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e60bfe9e-d2fa-4576-87f3-0a866b88d07d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d908890-4fe4-4349-92de-464c4165b185"}}}], "length": {"value": 0.0592066, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "468c39e1-9b75-4323-be99-3513b80c5ba1", "name": "l(r:p1rdm16862-p1rdt7699lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bfa76dc8-4007-4e52-9692-2eec7cb574e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e60bfe9e-d2fa-4576-87f3-0a866b88d07d"}}}], "length": {"value": 0.0187021, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ca527da2-14ed-422f-b70c-1bc7bd4d4a7e", "name": "l(r:p1rdt7701lv-p1rlv16397)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0cc95d09-c799-488e-81e8-50326a7da1ea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "323373a9-8e7d-4fb4-8970-dcc0e6d26c98"}}}], "length": {"value": 0.0805765, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f9812016-b945-4e02-8acf-7b54729433c8", "name": "l(r:p1rdt7704lv-p1rlv20070)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ef392d6-b408-4a7f-8a67-9fe43e1df582"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "571a4c92-95b6-4bc0-a25d-0d9239a41a89"}}}], "length": {"value": 0.0912722, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "69240808-930b-4994-9d23-dee6955da16c", "name": "l(r:p1rdm16872-p1rlv16401)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0797f1d0-3499-4f88-a749-fc576240f791"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eeb598c2-f0b9-44df-bfaa-be66e4dc3920"}}}], "length": {"value": 0.0257854, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "18b08e77-eb01-4b55-b1ce-98e572b7dd24", "name": "l(r:p1rdm16872-p1rdt7704lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ef392d6-b408-4a7f-8a67-9fe43e1df582"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0797f1d0-3499-4f88-a749-fc576240f791"}}}], "length": {"value": 0.0193937, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7cba66ff-a6ee-4381-9e47-2a5af2de3377", "name": "l(r:p1rdm16873-p1rlv20068)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5e00667-6368-49d3-a5dd-c574c79dba21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0b689f0-d4b1-4419-bff8-f72436625c60"}}}], "length": {"value": 0.0406184, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ba8749a8-823d-4c50-9058-f01580cfa960", "name": "l(r:p1rdm16873-p1rlv20069)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5e00667-6368-49d3-a5dd-c574c79dba21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f0e3c74-2d63-4612-b0e5-d986ebee0086"}}}], "length": {"value": 0.0750315, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9621505b-497f-4f4e-b57f-a04130b6eca0", "name": "l(r:p1rdm16873-p1rdt7704lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ef392d6-b408-4a7f-8a67-9fe43e1df582"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5e00667-6368-49d3-a5dd-c574c79dba21"}}}], "length": {"value": 0.019391500000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e7f8fc5c-5a80-4393-8e10-ac437b20b61d", "name": "l(r:p1rdt7712lv-p1rlv16412)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59a62487-c709-428e-9e97-c7c285a1305c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99f97a6b-4e94-4a35-ad00-12e7004ab5e3"}}}], "length": {"value": 0.0485398, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f0906201-838f-44bd-962b-5a532e582278", "name": "l(r:p1rdt7718lv-p1rlv16422)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6d10a4e-e7bc-4448-bca3-a5f2117b6198"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f367b63c-c4cb-4810-a270-8bd0153b7b32"}}}], "length": {"value": 0.013767300000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6fa6e077-a768-476b-84c5-2aa32a00b492", "name": "l(r:p1rdt7718lv-p1rlv16424)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6d10a4e-e7bc-4448-bca3-a5f2117b6198"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2242f1c-542f-4c1f-b3e6-19482cccde8d"}}}], "length": {"value": 0.013767300000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "067decd6-dc2e-405c-b604-7300ea1905a2", "name": "l(r:p1rdt7735lv-p1rlv16445)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96dcd934-01a0-4719-89bc-a18430edf179"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e090544-3c8e-4716-9dae-0b311a1017ea"}}}], "length": {"value": 0.0284282, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d86ce606-0132-488e-ba44-92843bfb8d12", "name": "l(r:p1rdt7790lv-p1rlv16570)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ed564b5-8d49-4ff7-94c2-b245981472e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53d578d8-8492-471b-8f66-233e489a3652"}}}], "length": {"value": 0.0553998, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7ea5b970-dc67-44e2-af2f-76936ea99183", "name": "l(r:p1rdt7954lv-p1rlv16905)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9dd5bb5-1410-4635-8a85-d23d7c3e55ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7578563f-d4b3-423b-a8f5-3ee91a042d19"}}}], "length": {"value": 0.0850821, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "00df3659-93b5-43ea-a55e-a0893faccc10", "name": "l(r:p1rdm17416-p1rlv16882)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e982887d-97c6-4af5-b536-a15a372b3379"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4faf40b9-9ade-45b5-ade8-3f1833605cd1"}}}], "length": {"value": 0.09884780000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "729ab8bb-81b7-460d-8b0e-e4f5ef25eda6", "name": "l(r:p1rdm17416-p1rdt7954lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9dd5bb5-1410-4635-8a85-d23d7c3e55ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e982887d-97c6-4af5-b536-a15a372b3379"}}}], "length": {"value": 0.0184307, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ef9a2339-09f7-486b-8e23-0b908af565b6", "name": "l(r:p1rdt7973lv-p1rlv16912)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3a96167-4b09-49c9-baf7-4fb588ecb002"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2308dc3-d10b-4049-862d-caf3356fa9a7"}}}], "length": {"value": 0.0637175, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2719d040-2a20-4bbc-bbf1-d5f6272f6310", "name": "l(r:p1rdt7973lv-p1rlv16988)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3a96167-4b09-49c9-baf7-4fb588ecb002"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11a633b0-2b09-4c66-94d4-d1c24cdd9cf5"}}}], "length": {"value": 0.0681669, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7cb3929d-dcf6-4fa6-bf71-8d2d79fbacd7", "name": "l(r:p1rdm17505-p1rlv16904)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53ed549a-9c24-4bdd-9e40-aee5308d8120"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c570ef7-c483-4c1e-b0fd-8712e8e9a7cd"}}}], "length": {"value": 0.0396092, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "792c1524-361f-42ca-81a5-8f88a601bd78", "name": "l(r:p1rdm17505-p1rdt7973lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3a96167-4b09-49c9-baf7-4fb588ecb002"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53ed549a-9c24-4bdd-9e40-aee5308d8120"}}}], "length": {"value": 0.0168466, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1313795b-a5f9-4cc6-a9c8-7943979110f3", "name": "l(r:p1rdt7983lv-p1rlv16919)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb63be48-94ec-4c9f-9991-77892e14171b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07e01053-37f3-4b9f-a9f1-d51bccd29803"}}}], "length": {"value": 0.079259, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "85650fc1-1735-4e05-8f26-86c5ca8437b9", "name": "l(r:p1rdt7983lv-p1rlv17033)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb63be48-94ec-4c9f-9991-77892e14171b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfa28657-cd8e-4700-a189-83e021f77bee"}}}], "length": {"value": 0.0492948, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0f5baa05-57eb-4dcd-b077-ae2d13649e82", "name": "l(r:p1rdt7986lv-p1rlv16922)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "415fe6e9-953e-40f6-8ae8-43834e4e6ce4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce315d98-1556-429b-aebb-0c868892396a"}}}], "length": {"value": 0.0143418, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "001d627b-af02-488f-b9c8-23280b783daa", "name": "l(r:p1rdt7986lv-p1rlv16957)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "415fe6e9-953e-40f6-8ae8-43834e4e6ce4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7dff1455-5154-429f-a33f-044d8501281d"}}}], "length": {"value": 0.0453768, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6476ae7e-8f41-498c-9da2-84e326f9d60a", "name": "l(r:p1rdt7986lv-p1rlv17063)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "415fe6e9-953e-40f6-8ae8-43834e4e6ce4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19130741-0fe1-4a12-8a55-96355609bccb"}}}], "length": {"value": 0.0371136, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e0da39bf-f183-4b18-9021-71a39d01f9bd", "name": "l(r:p1rdt7988lv-p1rlv16926)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94f12107-697c-4278-95e0-32b6eb49fdb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ba1d053-4462-4eb4-aca6-5ede38aa283c"}}}], "length": {"value": 0.00743277, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "150161df-4909-484b-95b0-d6b3d384dbc8", "name": "l(r:p1rdt7988lv-p1rlv17106)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94f12107-697c-4278-95e0-32b6eb49fdb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5439f343-8176-4d92-99d4-bb9209817f6b"}}}], "length": {"value": 0.00743277, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b7fe8781-6590-4253-9abb-c7288b33a95b", "name": "l(r:p1rdt8012lv-p1rlv16992)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5b22c57-7912-4e9f-9b06-6a8ff706a58d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57e8aa34-3967-4f22-a978-cb513c49c153"}}}], "length": {"value": 0.109333, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "93bde77a-daea-4cd1-9aac-96608150fd7e", "name": "l(r:p1rdt8012lv-p1rlv17069)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5b22c57-7912-4e9f-9b06-6a8ff706a58d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd48a076-5f8f-426a-b294-183700d1a123"}}}], "length": {"value": 0.0628588, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c75878bb-a8e9-45f7-ac9f-3112ab4daa2e", "name": "l(r:p1rdt8015lv-p1rlv17001)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6c5d7ff-cfcd-4b30-98db-eb44a95d6841"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f23214ee-3032-4403-9084-8117e89cb1cf"}}}], "length": {"value": 0.00814411, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4a06edff-3ac9-477f-afd1-857950e98149", "name": "l(r:p1rdt8015lv-p1rlv17028)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6c5d7ff-cfcd-4b30-98db-eb44a95d6841"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "213e6d98-ad57-4034-b2d0-4b096554cac2"}}}], "length": {"value": 0.00814411, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "963a379d-4526-40c4-a92c-040fcd1db98c", "name": "l(r:p1rdt8034lv-p1rlv17059)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "972fe574-f88e-4a8d-8845-d5baa2f378a7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "92aff718-b70f-4ea4-b38b-fae69a470c58"}}}], "length": {"value": 0.0530471, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "39ed0258-6338-449e-a516-59e9a08220e0", "name": "l(r:p1rdt8149lv-p1rlv17319)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9951633b-4311-4ca2-9316-3801be13fe97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9778ed5-f0c0-44de-b0d4-60659a54fa3b"}}}], "length": {"value": 0.0160827, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cee2f792-d80f-4b98-a645-57496b1a1a4e", "name": "l(r:p1rdt8149lv-p1rlv17334)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9951633b-4311-4ca2-9316-3801be13fe97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4970bc03-bc57-4a42-b0cb-66002af1709e"}}}], "length": {"value": 0.016006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1df0e133-12a9-410c-ac98-560dfc4918f0", "name": "l(r:p1rdt8150lv-p1rlv17320)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cd1ae47-6aaa-4b57-ba44-1e74f6ea54b7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79991b02-c0f1-4b9b-a55e-e9b4ff7c17d9"}}}], "length": {"value": 0.063086, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "815c3299-4558-40b9-b5fe-d5f0c27c11d7", "name": "l(r:p1rdt8150lv-p1rlv17326)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cd1ae47-6aaa-4b57-ba44-1e74f6ea54b7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ceb2d77-2da7-44df-9f28-69ed35835775"}}}], "length": {"value": 0.063086, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "499d0139-fa5c-45de-864f-e28786ab80fa", "name": "l(r:p1rdt8151lv-p1rlv17321)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a8deb5-b46b-4d4c-876c-b44b2258a6fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "00ed745d-78ae-47f6-b6ef-4edf8794ca6a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "4d608ad4-d94a-4b0b-8fcd-3c08ae50178c", "name": "l(r:p1rdt8151lv-p1rlv17321)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "00ed745d-78ae-47f6-b6ef-4edf8794ca6a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94ce8ee2-6f57-407a-93e9-c06f79d66262"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "4dceb5ed-b8a7-4331-90f0-5f93186eeaba", "name": "l(r:p1rdt8151lv-p1rlv17321)_s2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94ce8ee2-6f57-407a-93e9-c06f79d66262"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce41ac7c-06c5-435a-957d-c9dda83c1893"}}}], "length": {"value": 0.09433530000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d09084bb-a89a-4254-a73c-e94d3dc90fbd", "name": "l(r:p1rdt8151lv-p1rlv20188)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a8deb5-b46b-4d4c-876c-b44b2258a6fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abb24254-be79-45d4-8d9b-246b3e89c00f"}}}], "length": {"value": 0.00615959, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4ef03455-4b06-4b8f-af90-475cc6a09a60", "name": "l(r:p1rdt8153lv-p1rlv17325)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a542ca5-b24e-44dc-8b68-c00aa024afad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b96606c-9336-4299-be8d-295c84943a9d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "23108ceb-470b-432b-b6c3-701d156a5397", "name": "l(r:p1rdt8154lv-p1rlv17328)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32fefbef-e10b-4758-8c2e-ccafad49aa5d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a43eb022-d5e0-47c8-aa36-6ca0d212ab07"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "36ad5faf-d994-41eb-afb8-9a4fb8edcf6c", "name": "l(r:p1rdt8155lv-p1rlv17329)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51812cd8-eec8-4862-8413-d25a7e9862dc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61ef37c1-f14f-4b79-a428-d51a6f0d076a"}}}], "length": {"value": 0.0793038, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b52124cd-a5c9-4f18-9f6d-79b8143d4cef", "name": "l(r:p1rdm17903-p1rlv17330)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb2a5041-28a1-4fda-905b-caf53ebbefe3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48ad7bb0-8dd7-457a-b77d-6db2071c2fe7"}}}], "length": {"value": 0.0025319, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "11874623-6a90-44c5-b716-1180ab27ebdb", "name": "l(r:p1rdm17903-p1rdt8155lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51812cd8-eec8-4862-8413-d25a7e9862dc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb2a5041-28a1-4fda-905b-caf53ebbefe3"}}}], "length": {"value": 0.0391228, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a670c5be-e502-4ee5-bab3-d6830776dd9c", "name": "l(r:p1rdt8157lv-p1rlv17333)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa6d4429-8a95-4ebd-9e3a-9867734245bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33b66eb9-3b21-4f92-b19b-6a0eef4134d8"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "3c168ea4-60f1-40d7-9105-c60ebe5c0919", "name": "l(r:p1rdt8159lv-p1rlv20480)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1dd4660-3cd0-4709-b1ef-1c598e5e39fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5d0a174-d49d-4c7e-a669-092f6408edf4"}}}], "length": {"value": 0.0224012, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "42b10885-9f84-40fb-8096-ecdeabc0172c", "name": "l(r:p1rdm17907-p1rlv17336)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3484e698-3a4e-4a88-aaa3-1dc88cd9ac89"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b645969-9136-42a9-b5ac-7d2f1ff71959"}}}], "length": {"value": 0.0155741, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "711295b2-6d63-413f-8284-ba2877d64e97", "name": "l(r:p1rdm17907-p1rlv20492)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3484e698-3a4e-4a88-aaa3-1dc88cd9ac89"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7af262b7-285c-4d06-b7ff-2f2a1971055a"}}}], "length": {"value": 0.049942, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "daa257f3-0092-4324-ba2d-11ec7a94a4a1", "name": "l(r:p1rdm17907-p1rdt8159lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1dd4660-3cd0-4709-b1ef-1c598e5e39fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3484e698-3a4e-4a88-aaa3-1dc88cd9ac89"}}}], "length": {"value": 0.018672500000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2cbdeb9d-3636-4393-9326-b0240390e325", "name": "l(r:p1rdm17908-p1rlv20455)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6112cc26-bc37-4c72-8ef6-cd88f1296693"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8934db59-0c39-4838-9f8c-59a563cd9d54"}}}], "length": {"value": 0.0215008, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "06e87fff-fd19-45b8-bb9b-8cd0c6413c5a", "name": "l(r:p1rdm17908-p1rdt8159lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1dd4660-3cd0-4709-b1ef-1c598e5e39fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6112cc26-bc37-4c72-8ef6-cd88f1296693"}}}], "length": {"value": 0.0175631, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9a093498-1758-4c33-8c70-ea251e449258", "name": "l(r:p1rdt8160lv-p1rlv17337)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "232fed6b-fe0f-4a44-93e9-e6675b50c39c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5d7049e-9d30-474c-9033-3ad9b4487f7a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "259d0df0-c158-431c-8a14-d3db5f371846", "name": "l(r:p1rdt8161lv-p1rlv17338)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac7e489e-7249-4702-9ed6-131cad34500f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "331389ab-5d04-4648-83b4-3043198c774f"}}}], "length": {"value": 0.05601040000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "56875cf5-044e-43c9-b940-eee8bd16a486", "name": "l(r:p1rdt8346lv-p1rlv17702)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9560197a-21d1-4601-8bcb-213df4844f4a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7acb4e7d-cb06-4848-952d-7c68bb34b6db"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "e6dddecc-acad-4d45-849a-d67e98fe7205", "name": "l(r:p1rdt8405lv-p1rlv17781)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "408d5d7b-fc71-46bb-8de0-2d4e628c29b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a52db2ff-b782-40c1-828a-c65f6929b2fc"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b38ef92b-b5a5-4354-a862-4ff2cfcaf0e2", "name": "l(r:p1rdt8408lv-p1rlv17787)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3fe0f77-a7c1-48e3-94aa-30b69f20ca65"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c9c1d9f-eeff-454f-b3d0-7e7de837694c"}}}], "length": {"value": 0.030519200000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d2fdb455-533e-494f-b3ae-7a6f434a6456", "name": "l(r:p1rdt8408lv-p1rlv18044)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3fe0f77-a7c1-48e3-94aa-30b69f20ca65"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b40fac8c-a99b-4baa-940a-26565ba7d62b"}}}], "length": {"value": 0.030519200000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2cccc34f-8ec9-4a07-94e6-5ea9394c8395", "name": "l(r:p1rdt8414lv-p1rlv17798)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fca92353-c013-4c41-8507-ec8704410834"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9dba02d-086c-4906-9c6f-86532e3384c0"}}}], "length": {"value": 0.0626486, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3fa99df5-af3e-4d19-92fe-6c6b8fa2435f", "name": "l(r:p1rdt8422lv-p1rlv17810)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfe35c35-8164-4825-81e3-10a2ece2cb27"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3887a879-0783-4703-8a24-32b7e3b4f39d"}}}], "length": {"value": 0.064621, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "29fcd1b6-7f66-4926-8f32-6b14ca47aa39", "name": "l(r:p1rdt8422lv-p1rlv17847)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfe35c35-8164-4825-81e3-10a2ece2cb27"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f7776e4-a81f-48d2-b3c0-d70bfa48164e"}}}], "length": {"value": 0.114619, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6a2c3743-a96c-4193-afff-9f66a9993e4a", "name": "l(r:p1rdt8422lv-p1rlv17876)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfe35c35-8164-4825-81e3-10a2ece2cb27"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75e55237-b847-4fb7-a141-a0771bd868c6"}}}], "length": {"value": 0.0889709, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1cfd7122-29e2-4593-8a29-d37c7bab1574", "name": "l(r:p1rdm18545-p1rlv17961)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7421f5c-bf5c-4d01-aa14-ba657f242080"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2716887e-1701-4a78-805b-96da0781c7f8"}}}], "length": {"value": 0.07666780000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1fc0a354-eb4d-4fef-b7b3-9ac5204835bf", "name": "l(r:p1rdm18545-p1rdt8422lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfe35c35-8164-4825-81e3-10a2ece2cb27"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7421f5c-bf5c-4d01-aa14-ba657f242080"}}}], "length": {"value": 0.0192775, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6813915a-9540-4a06-8171-305ffaddeb8f", "name": "l(r:p1rdt8434lv-p1rlv17857)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdc5ef2a-c0d0-4702-b6c6-df08af1e8746"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0827675c-2467-403d-822e-5f74cd6296c5"}}}], "length": {"value": 0.0235179, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ae004d86-bb53-4a39-b217-28aba419df2a", "name": "l(r:p1rdt8436lv-p1rlv17877)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b24c9345-625f-499d-96cf-30b2de5839b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f44b0293-61e5-4054-b2d7-4a113df92b3c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "90848665-6e77-434a-9664-022c4b37b0ca", "name": "l(r:p1rdt8439lv-p1rlv17897)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a38f544-e250-4fc9-942c-946c5cde0a33"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f74f217-4765-406d-9646-d8f46377ef0a"}}}], "length": {"value": 0.0231504, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "615ebf6f-8bb0-491b-a80f-70ff9109b5c5", "name": "l(r:p1rdm18631-p1rlv17909)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6460e5c-839d-4f9e-b9d6-b187fddb9ab6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab733d49-bb36-4631-8824-1967f98f758a"}}}], "length": {"value": 0.055777700000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9d77603e-e62a-40c8-8d7b-5150e4e96a38", "name": "l(r:p1rdm18631-p1rdt8440lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "049362b4-49de-4e80-921e-ff763aaab2d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6460e5c-839d-4f9e-b9d6-b187fddb9ab6"}}}], "length": {"value": 0.017871200000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "48a7466b-1d73-416b-809a-83537dd3441d", "name": "l(r:p1rdm18632-p1rlv17969)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7633fe6b-a48b-4e7d-90e6-a38b8a861936"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ccaf70a-35d8-4f16-b632-e282fe30b5ca"}}}], "length": {"value": 0.018069200000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "19cb6fa7-25c3-47ca-a366-957be38b8701", "name": "l(r:p1rdm18632-p1rdt8440lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "049362b4-49de-4e80-921e-ff763aaab2d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7633fe6b-a48b-4e7d-90e6-a38b8a861936"}}}], "length": {"value": 0.0178577, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2caa96e4-c274-43dc-b1e4-5f11301d9ccf", "name": "l(r:p1rdt8441lv-p1rlv17912)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72c8f08a-0ba5-413e-a805-f9436b41ff29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3eb66d3-0271-4842-8893-9a58f64e0279"}}}], "length": {"value": 0.009300020000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "323d26e7-5b43-454b-a45c-aec7e307de9d", "name": "l(r:p1rdt8442lv-p1rlv17926)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b5ae28a-95f8-4023-aa23-36809fe96b10"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2812bbb1-0bb0-499f-a394-0995784bb7bc"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "186217d6-9a20-48aa-9949-c80f28bafe57", "name": "l(r:p1rdt8444lv-p1rlv17960)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "978920e8-edf9-4bee-85f9-45f4081ed0ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "215a5974-e23b-46f0-bde9-f5ad16fdfaf8"}}}], "length": {"value": 0.00946867, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a2666500-718c-4b6a-b104-d85550e22cdc", "name": "l(r:p1rdt8444lv-p1rlv18071)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "978920e8-edf9-4bee-85f9-45f4081ed0ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86917829-123c-4fda-9809-dc61430a9fef"}}}], "length": {"value": 0.00946867, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "af700dca-e6b2-417d-a811-cc93dc290724", "name": "l(r:p1rdt8445lv-p1rlv17962)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e0923da-550b-479f-b3d8-3e0320db6701"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec99daac-e0be-4ea1-ba4f-185d4943396d"}}}], "length": {"value": 0.07683860000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "529ee728-9a14-4ce5-bbf5-baa1001689c5", "name": "l(r:p1rdt8447lv-p1rlv17987)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5dbc3459-6a17-4075-899a-6aab16fb3ab7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0771ebfa-5eaf-4ae8-94f1-86de7a656f58"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "04dd8850-4fe7-4c15-8a87-50bc76145038", "name": "l(r:p1rdt8450lv-p1rlv18053)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b4216c8-9e99-446c-ad09-5a09f046dd59"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4aeda1c7-41be-43c8-82e5-d7a347db86a8"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "63c8dbef-8a8b-4ce8-95cf-6fc4728d963d", "name": "l(r:p1rdt8456lv-p1rlv18100)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d094b779-ebcc-4837-9ccb-31808e2a544b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4863d28-4ee2-479d-accb-60b54f472fe7"}}}], "length": {"value": 0.04190880000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "300dd493-34b4-4375-892d-eadd8fe22746", "name": "l(r:p1rdt8458lv-p1rlv18129)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e597d8da-e876-44a5-a109-1ce84527c557"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "115a848f-f6f3-48f0-9f33-5a9103f1a892"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "43c4c411-e502-46b8-9442-5f4d7dd2ea62", "name": "l(r:p1rdt8470lv-p1rlv18166)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "edb15d92-f98a-4fa2-8129-ad8a39e0dc0c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "431692e5-2917-41ea-aafc-96be180b7e27"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "be9ad055-8cbd-4405-8241-9bc60395472f", "name": "l(r:p1rdt8490lv-p1rlv18192)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a84e1424-7faf-4077-9461-b39460f10ef0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c3e08a8-ea88-423d-b361-69509f7ab8fa"}}}], "length": {"value": 0.0095095, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bdc387c3-9bdc-43d9-890f-0d718eba7c3a", "name": "l(r:p1rdt8490lv-p1rlv18198)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a84e1424-7faf-4077-9461-b39460f10ef0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a7cb078-af6c-4cd5-9aca-48f515f6e711"}}}], "length": {"value": 0.0095095, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f668b67f-606b-4d28-9cc3-1943007f22e4", "name": "l(r:p1rdt8492lv-p1rlv18197)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "127e4cc7-6413-4482-9ec3-40f8bde02d0c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5e240e8-b27d-4181-a7ee-a004d3f5c58a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "81b9170e-c68f-4cac-a3d4-fbc567e0a98c", "name": "l(r:p1rdt8802lv-p1rlv18960)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95a1a7c7-6055-47c9-a742-c1b81f6c7478"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9178fdee-311f-40f5-bdd6-9b474a05247e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "5c797127-ea67-442a-b638-200eacfd668c", "name": "l(r:p1rdt8805lv-p1rlv18967)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "715c92fa-2470-4869-8d5f-0b4f3f8360d4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eef4f0cf-6e51-45e1-8b6e-84171f7cbef6"}}}], "length": {"value": 0.0733915, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "dd30ae2e-bd36-4ebb-abb3-ba2b2c134191", "name": "l(r:p1rdt8898lv-p1rlv19157)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6ff626c-d2fc-4b97-9013-4fd544d946a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cf28b5d-d8d4-4883-a396-2d1ad9b70564"}}}], "length": {"value": 0.0657162, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "147a1cb3-41c2-49b8-8b56-b4683e957a72", "name": "l(r:p1rdm19752-p1rlv19149)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09d59048-6e1b-4f7f-b161-81163809eb25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67a4600d-65c3-40d7-ad28-e8e37ff77dcb"}}}], "length": {"value": 0.046789, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "0ca56993-e151-46ec-bc06-2732eef8e2a4", "name": "l(r:p1rdm19752-p1rlv19160)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09d59048-6e1b-4f7f-b161-81163809eb25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7c1d210-ee87-46c5-b408-ad221cbeed04"}}}], "length": {"value": 0.057637900000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "d4f9decd-9338-4453-85d3-5c8b5ac0490f", "name": "l(r:p1rdm19752-p1rdt8898lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6ff626c-d2fc-4b97-9013-4fd544d946a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09d59048-6e1b-4f7f-b161-81163809eb25"}}}], "length": {"value": 0.019358300000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "cb6ddaa3-2b16-42bd-bce5-bd8a267eab2f", "name": "l(r:p1rdm19755-p1rlv19166)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7664d29-bbc0-4465-a00a-82af048b86e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "994f6392-f4e5-4ff8-9eeb-5849cd035912"}}}], "length": {"value": 0.0880892, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "6a7bb342-4fcd-424d-861f-0ee25541d40f", "name": "l(r:p1rdm19755-p1rdt8898lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6ff626c-d2fc-4b97-9013-4fd544d946a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7664d29-bbc0-4465-a00a-82af048b86e5"}}}], "length": {"value": 0.0437869, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "f229b79a-47fa-4ab8-9ea2-b416d4caf8fc", "name": "l(r:p1rdt8901lv-p1rlv19161)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d53c0a2-78cc-4988-85a4-884ef039f5fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16df6b90-d049-4160-b148-b888e03acb82"}}}], "length": {"value": 0.0671759, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6bdd0d1e-8826-457f-a773-5a2a945a84ce", "name": "l(r:p1rdt8904lv-p1rlv19168)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e111e213-bcbe-42c4-b6ab-2c734ff5341c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f8c76ca-40ea-4f7d-8042-66edd484f065"}}}], "length": {"value": 0.045782800000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "741a9472-dbc2-427c-a02b-462c15f35f7b", "name": "l(r:p1rdt8904lv-p1rlv19174)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e111e213-bcbe-42c4-b6ab-2c734ff5341c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0fc7d43-4f82-4100-99bf-6e30e03e95ce"}}}], "length": {"value": 0.0128136, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "96ca1afa-d534-4724-8ecb-b6702cfd67b7", "name": "l(r:p1rdm19776-p1rlv19184)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b9386f2-376d-4439-a9a4-3eefc238dafe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50750ddb-80db-4d5f-bc62-4bbfc600a7ef"}}}], "length": {"value": 0.075847, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "72bd06c1-2522-4912-ab13-24cec5f2b774", "name": "l(r:p1rdm19776-p1rdt8904lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e111e213-bcbe-42c4-b6ab-2c734ff5341c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b9386f2-376d-4439-a9a4-3eefc238dafe"}}}], "length": {"value": 0.010418900000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a90947b1-4fd1-4387-bdff-d59c20a3fb90", "name": "l(r:p1rdt8905lv-p1rlv19169)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2777cc-f3fd-491f-a10b-4ed381cb948d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4e8183-9148-477e-aa1b-ff31a5324273"}}}], "length": {"value": 0.0299426, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "04d7afca-c271-4057-ab48-201ee8bcd8a3", "name": "l(r:p1rdt8905lv-p1rlv19171)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2777cc-f3fd-491f-a10b-4ed381cb948d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fffe26f7-c4cc-420e-ab17-754cb0d9e659"}}}], "length": {"value": 0.0502658, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "21e7a836-3ea5-407e-bd70-f3443102eebd", "name": "l(r:p1rdt8905lv-p1rlv19173)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2777cc-f3fd-491f-a10b-4ed381cb948d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21fec301-b67c-4042-a074-caf406c7f0b5"}}}], "length": {"value": 0.0431542, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7c1587be-1e8f-466e-8791-3a41354606c0", "name": "l(r:p1rdt8905lv-p1rlv19188)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2777cc-f3fd-491f-a10b-4ed381cb948d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47e24942-486d-46f1-a40f-0da5c93c013a"}}}], "length": {"value": 0.00975868, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4637e31d-b157-4290-a8cb-4596fb7db783", "name": "l(r:p1rdt8905lv-p1rlv19194)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2777cc-f3fd-491f-a10b-4ed381cb948d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7daa1d3-6249-447d-a260-65de5ec0a470"}}}], "length": {"value": 0.0629287, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3bca6f74-5988-47c8-a80c-3cd6b0a69bb6", "name": "l(r:p1rdt8911lv-p1rlv19183)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c306f79a-0240-465e-a486-d0f11614fc57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "89bde057-807b-415c-9135-267c6bf43c44"}}}], "length": {"value": 0.0132248, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7550f50f-c63b-48ad-8fdd-dc45f65120ce", "name": "l(r:p1rdt8911lv-p1rlv20296)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c306f79a-0240-465e-a486-d0f11614fc57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a8ae6dc-884d-48d8-9995-fe3936ad019c"}}}], "length": {"value": 0.0132248, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "418f522f-9800-4e1d-a31b-cf04a40a6664", "name": "l(r:p1rdt8915lv-p1rlv19189)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2fbbca23-6473-4344-ac2e-cc97078b3d8d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5fecc64a-4783-4ecb-a0d0-7e60d1cf6184"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "632311c1-925c-4de3-92fc-6b27efe14c9f", "name": "l(r:p1rdt8916lv-p1rlv19190)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d268e33-708d-4bae-8348-cad27fd0d81a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4aee02d4-8663-455b-a197-55b6b1470895"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "40f4ca55-ed5c-4973-971b-35cd67ba354e", "name": "l(r:p1rdt9075lv-p1rlv19667)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6752e8f4-9e37-476d-aec2-4a2fe7c1e2dc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33dcb037-4cc8-480f-aac4-bc95e54e165e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b4340e3d-5abb-4a2e-ab02-77baaf44385e", "name": "l(r:p1rdt9076lv-p1rlv19698)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdd64386-e256-47f8-8cef-1c933f993a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14b1ab4e-b22d-4a98-8131-fc72c923c735"}}}], "length": {"value": 0.055055700000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7a80ce41-b341-4153-b901-ce184294afbb", "name": "l(r:p1rdm20204-p1rlv19668)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd00c91a-01a8-4aad-b740-b06a654d631b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6427f66-2e22-40bb-83f1-2a8b1be9191a"}}}], "length": {"value": 0.0202803, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "049118fd-f5d6-4f65-9749-8f71e013199a", "name": "l(r:p1rdm20204-p1rlv19699)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd00c91a-01a8-4aad-b740-b06a654d631b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48654a82-ac11-4542-94ec-8f731138e1a8"}}}], "length": {"value": 0.0338608, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2c76a5dc-ab24-4233-b561-76095bf798b1", "name": "l(r:p1rdm20204-p1rdt9076lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdd64386-e256-47f8-8cef-1c933f993a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd00c91a-01a8-4aad-b740-b06a654d631b"}}}], "length": {"value": 0.0174413, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "eb46a639-7f1d-4e52-9a81-3b86dadfb400", "name": "l(r:p1rdm20205-p1rlv19686)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce8f50bb-90fb-49b8-8a16-1bbbb6a0c82c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47f5777d-2c8d-48c2-bf28-386f3f3dbac4"}}}], "length": {"value": 0.0229841, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "172f2ac8-d408-43a5-8f2f-85b7eb96c199", "name": "l(r:p1rdm20205-p1rdt9076lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdd64386-e256-47f8-8cef-1c933f993a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce8f50bb-90fb-49b8-8a16-1bbbb6a0c82c"}}}], "length": {"value": 0.017440300000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "642532af-cf6d-4892-bfa9-52b019bfbf8a", "name": "l(r:p1rdt9077lv-p1rlv19669)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b83eaaa-a092-42ca-a746-db4d9658d62b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96d3079a-02f1-4c89-ad75-fd0a438c9cf4"}}}], "length": {"value": 0.0293066, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b1bf45c3-70c8-4201-8c1a-d7d811dc7e70", "name": "l(r:p1rdt9077lv-p1rlv19675)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b83eaaa-a092-42ca-a746-db4d9658d62b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0031ab1b-d82d-40a5-b41e-bc6f6cb53069"}}}], "length": {"value": 0.00129939, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "a2668d78-c842-45e2-aeba-92c501e738bf", "name": "l(r:p1rdt9077lv-p1rlv19695)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b83eaaa-a092-42ca-a746-db4d9658d62b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35fe21a1-f817-426e-9e42-f1f33876dd7d"}}}], "length": {"value": 0.0295629, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7c77322f-3c54-4db1-b408-c1bcda2a0af3", "name": "l(r:p1rdt9084lv-p1rlv19681)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f0e4f59-8a46-4abf-9f06-e0383a59a45d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83afc678-d577-4ef1-afa2-8e3f915a158b"}}}], "length": {"value": 0.0407307, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ef70211b-06c5-4723-acbc-8f9aa7fe7d51", "name": "l(r:p1rdt9085lv-p1rlv19682)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "565bbfb1-a28f-4db2-be48-cbd58972025a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "811acd48-b61c-4a42-b76e-f995961c450e"}}}], "length": {"value": 0.0479288, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3052d3d1-b680-42ca-9619-45b322a57260", "name": "l(r:p1rdm20223-p1rlv19701)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec27727b-2bb8-4df2-9ddf-46282728c2c0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b5d936f-b3e0-408e-aabd-d3ebb7b869b0"}}}], "length": {"value": 0.05942600000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8693b634-c1ba-4076-b23e-61ae440e0c6b", "name": "l(r:p1rdm20223-p1rdt9085lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "565bbfb1-a28f-4db2-be48-cbd58972025a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec27727b-2bb8-4df2-9ddf-46282728c2c0"}}}], "length": {"value": 0.0186112, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4af17e9c-30e9-42ab-a616-44bee74bb9ea", "name": "l(r:p1rdt9089lv-p1rlv19689)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8108ac8-2807-4a40-85c2-db21efaadadb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "578b5df8-1dd8-41d9-b6dc-db75db5b115e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "a1434937-97ae-4da2-89f7-ebd1a788eb6a", "name": "l(r:p1rdt9090lv-p1rlv19690)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fc84159-09b1-4ca9-9a7a-a4fecab19f83"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2709a70-1a7d-454c-90fd-377e416a0071"}}}], "length": {"value": 0.0658315, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "67edc557-f853-458b-902b-2b073085da46", "name": "l(r:p1rdt9091lv-p1rlv19692)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e93ea18-150d-4d80-bac7-f3e1b87c5b4e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b10b272a-2efb-4e19-9921-d4081fb45778"}}}], "length": {"value": 0.0495767, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "86030b36-5fb5-416e-9704-398ab3aab79f", "name": "l(r:p1rdt9093lv-p1rlv19702)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f0726b7-3050-4c78-9c06-b9fd0c863ff3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37f72c85-61f7-4a42-94b0-6a627195458c"}}}], "length": {"value": 0.0423003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "41164760-4968-427a-ab0d-54100e9f5dc4", "name": "l(r:p1rdt9264lv-p1rlv20064)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c01a9b2-b002-4279-905e-950452f64f32"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aaea76fa-797e-46c5-a70f-a973977db841"}}}], "length": {"value": 0.0166628, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5e7381fe-5c31-423e-aa3a-7d6619d0c6d3", "name": "l(r:p1rdt9264lv-p1rlv20065)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c01a9b2-b002-4279-905e-950452f64f32"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea48ffa1-bdb3-4c15-96c9-ff7d7f34824f"}}}], "length": {"value": 0.0166628, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b84af902-253c-4e92-9494-157b730e98d1", "name": "l(r:p1rdt9265lv-p1rlv20066)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "77d62813-61d3-4afd-9f21-869e2ea23e17"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f450eeb4-3d87-4ae5-a6d6-958d7efd2712"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "2f422366-4e22-4f2c-8d50-1c6ba8a3374c", "name": "l(r:p1rdt9266lv-p1rlv20067)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78278589-be2d-4d99-9c03-92c221348917"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66a710fb-26c7-4465-b7ea-43ec107008dc"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "4f7d87f3-0ea4-4d93-b95a-cbe87c41dbc3", "name": "l(r:p1rdt9298lv-p1rlv20130)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "208f222c-45db-445f-ba0b-a4a195ca68a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ffc82be6-f3f8-4a68-b6e6-da60b137329c"}}}], "length": {"value": 0.0378956, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "bfcb695e-ecef-4564-813d-f2cb6bad6682", "name": "l(r:p1rdt9302lv-p1rlv20138)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180fad26-0e7d-4e2c-ba17-c8e3315ca278"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d635a151-2d13-47e9-8043-a214415a5b5e"}}}], "length": {"value": 0.057895600000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "39176fb1-de94-4c16-b64e-596ad25ee5f4", "name": "l(r:p1rdt9310lv-p1rlv20146)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4940a0e-dcc2-45fb-baa9-aadc84f8e882"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d615e93-a289-41ec-bda0-3b72bf15677e"}}}], "length": {"value": 0.052341200000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "71d34c49-4330-4c50-990a-3197e3ca5532", "name": "l(r:p1rdt9311lv-p1rlv20147)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9e0aa7d-9097-4370-8f5e-52a5885da85c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16b2add7-6a6d-4359-ad6f-f60edf435a4c"}}}], "length": {"value": 0.0259737, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8f3ee985-bbf9-4676-98e9-06a7c1d0a3d7", "name": "l(r:p1rdt9311lv-p1rlv20163)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9e0aa7d-9097-4370-8f5e-52a5885da85c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e938635b-e0d2-4e1b-a312-5a8f51e1dd7a"}}}], "length": {"value": 0.0357477, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ef39c360-8161-46c8-91bb-76651bc2d55f", "name": "l(r:p1rdt9312lv-p1rlv20148)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a21f5ca-51ef-4f81-8229-163182f011cf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4a0c2f2-f75e-4c9c-b3f7-d8d9ada9cb82"}}}], "length": {"value": 0.0268922, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3e7fdcaf-686b-496f-b34f-388785ad42a5", "name": "l(r:p1rdt9312lv-p1rlv20160)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a21f5ca-51ef-4f81-8229-163182f011cf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27dfea92-734e-49d3-b245-dc933df66889"}}}], "length": {"value": 0.0268922, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bc01fb01-4d37-4631-af7f-19d7e8269bbb", "name": "l(r:p1rdt9314lv-p1rlv20473)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3df13d91-365e-411b-917d-b28df5989280"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3eb214b9-827f-4995-a862-907be02b029d"}}}], "length": {"value": 0.0624435, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f48d1d5e-4709-4de9-b25d-ef596616a9fe", "name": "l(r:p1rdm20686-p1rlv20151)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5930295-0e44-4498-ae22-7647b72c1fa1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "956f4975-7383-4e0b-9114-d333a6ec4005"}}}], "length": {"value": 0.0773067, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c8ae9e69-9a3a-410a-9fd2-5ad1838b01c7", "name": "l(r:p1rdm20686-p1rlv20456)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5930295-0e44-4498-ae22-7647b72c1fa1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7a43aa6-2be8-4320-8089-57d388633c6b"}}}], "length": {"value": 0.0422263, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "97870ca0-fce4-48b0-85c2-87b76b884161", "name": "l(r:p1rdm20686-p1rdt9314lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3df13d91-365e-411b-917d-b28df5989280"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5930295-0e44-4498-ae22-7647b72c1fa1"}}}], "length": {"value": 0.0198942, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3435161e-0808-453b-ade5-697634ed4656", "name": "l(r:p1rdt9316lv-p1rlv20153)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c97a99f-545b-49cd-b1fe-4fd9e04bf37f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef20846d-d685-4c65-8dfb-bc23317501c5"}}}], "length": {"value": 0.021752800000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "633b6dd6-6a15-47ed-9d97-aebf2d9b5b6d", "name": "l(r:p1rdt9333lv-p1rlv20182)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a68a1c01-a04c-4af6-b1c8-02ddd1d67e0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20f93381-3834-4265-b1ec-5767d171ce0a"}}}], "length": {"value": 0.0263788, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b3b2c026-7b70-40e5-8478-180fd8809d5e", "name": "l(r:p1rdt9377lv-p1rlv20277)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e98299cb-8bad-49ea-8627-f3cfe01b9e23"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb7a8747-a076-469c-a150-35f6763157ec"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "087026c8-269c-4769-9c6f-af9a90b11306", "name": "l(r:p1rdt9381lv-p1rlv20281)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e37f182-5a60-470d-8f5b-ba145cc27973"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f23405b-432f-45ff-a7b1-0b7147cddfc8"}}}], "length": {"value": 0.0253793, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "59b8b45a-c9f3-49e3-8323-0d7dd87f9cb1", "name": "l(r:p1rdt9381lv-p1rlv20309)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e37f182-5a60-470d-8f5b-ba145cc27973"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e5718ad-0b70-4ea4-b2f2-31f0ea5c5d5b"}}}], "length": {"value": 0.0253793, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "26c34058-4892-4440-845b-5d3851809b0c", "name": "l(r:p1rdt9384lv-p1rlv20284)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abd09ea6-221c-47d9-beec-1062e0dd4aa7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25837ab0-0fb8-4346-94ad-561ff9ff7f0c"}}}], "length": {"value": 0.00420309, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9c16c054-b1ff-4e91-9010-39b32b8e0c3c", "name": "l(r:p1rdt9396lv-p1rlv20300)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc7e0a25-d6d6-4b07-b3dc-4fe5646915e2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da62d78e-e221-423a-8da0-8d36ce1f7508"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "d348f254-0831-467d-a2cf-24cff48b1fdc", "name": "l(r:p1rdt9413lv-p1rlv20333)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8180ee90-a46e-4d85-9742-d47b24f5e169"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c23afdc0-ab93-4d43-8eec-613eab21cd74"}}}], "length": {"value": 0.055563600000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d39e9443-e092-4bb9-890c-ec952b4704b1", "name": "l(r:p1rdt9413lv-p1rlv20358)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8180ee90-a46e-4d85-9742-d47b24f5e169"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b5d2dfa-895b-4afc-a7fe-449960adba41"}}}], "length": {"value": 0.055563600000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "5bf01fa7-0a38-4b2d-b944-93837af9be6a", "name": "l(r:p1rdt9463lv-p1rlv20432)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a015abb-ec63-4b31-9314-283b8499646e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4b5327a-85a3-496c-859c-f887a38513cd"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "e58c5ea4-bad0-4ebb-8dbd-9ba73b522dc9", "name": "l(r:p1rdt9468lv-p1rlv20451)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4dbe1628-cd17-4f37-af2b-dd752c290fa4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c37708d8-1e83-4e76-ac7f-0d29ba6b7c4e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "d36d6ce0-a328-49e6-8589-761a2846b82e", "name": "l(r:p1rdt9469lv-p1rlv20453)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09613257-d4cb-4c50-b35a-8aefc637c0c9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4e21b79-d2be-4a53-be46-32331e61f89c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "607be846-24c7-4d25-9222-e26430fd02e8", "name": "l(r:p1rdt9470lv-p1rlv20459)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1ab8727-2758-4513-8a7d-e02381faf1e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dfcfdbf-0051-4eef-bea6-97446cee21e4"}}}], "length": {"value": 0.0117286, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "03097dee-3563-430d-b479-e6da3aad6765", "name": "l(r:p1rdt9470lv-p1rlv20499)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1ab8727-2758-4513-8a7d-e02381faf1e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af153ed-ed39-4433-ac12-19dfdb7b6bef"}}}], "length": {"value": 0.0117286, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "abbb58b1-e018-43c7-8d8a-c43034cd923f", "name": "l(r:p1rdt9473lv-p1rlv20465)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c14c3211-a0d5-464f-820c-cab04764d907"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4759390d-43ec-45c9-9cca-320020dc1150"}}}], "length": {"value": 0.0334443, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4d466a6c-7eae-4477-a58b-84b46559fe6e", "name": "l(r:p1rdt9479lv-p1rlv20502)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6a8f268-6a5a-4b23-bd91-53c6b031442a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cacd3e49-55aa-4f05-bd7d-ae8aba0af87f"}}}], "length": {"value": 0.0132405, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "35f3ce10-7ea2-43a6-92f7-0e66c65507eb", "name": "l(r:p1rdt16638lv-p1rlv38126)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac361065-6b3c-4ac6-96d5-9b474eb3b80f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa4eed95-33b7-4827-8744-52d14149b386"}}}], "length": {"value": 0.00896862, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "950103b1-9ec6-4ba5-b24d-ea8b8cb59b5b", "name": "l(r:p1rdt16725lv-p1rlv38269)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bae9a352-584d-4cf0-9ebd-eb280b684e78"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cbb9976-253c-4863-899f-9218c4496688"}}}], "length": {"value": 0.00555125, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cf1cfe51-e7f4-4574-8253-da4972b54c2b", "name": "l(r:p1rdt7983-p1rdt8012)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bfb33cd-0cf1-455d-81e7-3d0472fa1b41"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e261b565-1f57-4cdc-bdd6-e045ee55d290"}}}], "length": {"value": 0.319354, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3b48fbf7-1282-4f8c-a6a8-8ae9f3b90bbf", "name": "l(r:p1rdt8012-p1rdt8034)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f83d22a-fa1e-4a4e-aab9-a9dea8ee06e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bfb33cd-0cf1-455d-81e7-3d0472fa1b41"}}}], "length": {"value": 0.0383866, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6243de73-7829-4099-a0ab-20bbf6c6ecea", "name": "l(r:p1rdt7954-p1rdt8034)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21e15d54-eab8-4204-9ed6-407fd8684700"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f83d22a-fa1e-4a4e-aab9-a9dea8ee06e5"}}}], "length": {"value": 0.256854, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9953443a-e512-47b5-b2da-2f9e9ddca7fc", "name": "l(r:p1rdt7954-p1rdt7973)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "016e4575-cd41-4993-be9b-5e5236a139ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21e15d54-eab8-4204-9ed6-407fd8684700"}}}], "length": {"value": 0.0497607, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a53ed3ef-f09a-4551-b82a-b6207878ef9a", "name": "l(r:p1rdt5172-p1rdt7973)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ea481f8-b9c7-4067-9bfb-4f7cdc5dee15"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "016e4575-cd41-4993-be9b-5e5236a139ae"}}}], "length": {"value": 0.289407, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "2c820636-d095-4272-9f89-d921819ff2af", "name": "l(r:p1rdt5155-p1rdt5172)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16712e10-4c7f-428b-917b-135ab3c2d4b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "afc636ed-f90c-4c48-822b-e86890d36f3b"}}}], "length": {"value": 0.0981862, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "cef0b639-e95b-4129-9dda-79e15491f213", "name": "l(r:p1rdt5155-p1rdt5172)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "afc636ed-f90c-4c48-822b-e86890d36f3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ea481f8-b9c7-4067-9bfb-4f7cdc5dee15"}}}], "length": {"value": 0.03419850000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "42c7cdb3-0fc1-4744-a4cb-bdb92a0ec9f0", "name": "l(r:p1rdt5155-p1rdt5201)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c289632-ba52-4b65-b6da-ac76b1477246"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16712e10-4c7f-428b-917b-135ab3c2d4b3"}}}], "length": {"value": 0.163704, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0e56a149-003c-40f3-90b4-32c09c9a86eb", "name": "l(r:p1rdt5159-p1rdt5201)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c289632-ba52-4b65-b6da-ac76b1477246"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee606236-08d7-4258-96c9-e9104f15b467"}}}], "length": {"value": 0.247666, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c41ff1f4-216c-4b99-9559-edc06bc0b68c", "name": "l(r:p1rdt5159-p1rdt5201)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee606236-08d7-4258-96c9-e9104f15b467"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90fb2270-4759-4779-80c1-7f93d66e1c53"}}}], "length": {"value": 0.0252803, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3b106144-995a-42f6-9105-373bd1547600", "name": "l(r:p1rdt5180-p1rdt5201)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86d3f96e-ffe2-459f-a2f1-b63d7bf138b8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c289632-ba52-4b65-b6da-ac76b1477246"}}}], "length": {"value": 0.165958, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "64b0948b-beb3-4234-9522-002661698319", "name": "l(r:p1rdt5923-p1rdt8346)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fec8a81-a151-4d8f-adc7-6d6d87d7759f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14b429c3-41da-4123-b661-40cbdfaf33e0"}}}], "length": {"value": 0.457454, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9be8e2a3-ed3b-4de7-8f25-6382fec041a4", "name": "l(r:p1rdt5923-p1rdt7988)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48e4b67a-0a47-48f0-b787-0a639db89caa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fec8a81-a151-4d8f-adc7-6d6d87d7759f"}}}], "length": {"value": 0.342603, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "cfb719d9-877c-4453-87ef-d4b5173d026f", "name": "l(r:p1rdt5180-p1rdt7988)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "893d2436-cd6c-40ad-90af-64ba1ac23f6e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48e4b67a-0a47-48f0-b787-0a639db89caa"}}}], "length": {"value": 0.958025, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4d35cd22-a1ac-48df-ae3c-d5a13715712d", "name": "l(r:p1rdt8447-p1rdt8456)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0089e5ea-d706-4a74-812f-654ae73eabcf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13b8cfc1-d8eb-4f47-b024-c1daacf3771d"}}}], "length": {"value": 0.30374700000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b83c03fc-f796-48d3-ad3b-2a3a22f58722", "name": "l(r:p1rdt8414-p1rdt8456)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34054ef8-8942-4471-ac14-43c6a37e5a16"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0089e5ea-d706-4a74-812f-654ae73eabcf"}}}], "length": {"value": 0.05634, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9e912236-8d08-4c01-94bf-41467552e199", "name": "l(r:p1rdt6272-p1rdt6274)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a53624b-8538-4cce-b588-c774875af31b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ac93b23-1041-486e-a16e-861082c92f35"}}}], "length": {"value": 0.108002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1c2a2bab-c82d-4a38-b710-8c8dfebf7049", "name": "l(r:p1rdt6272-p1rdt6274)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ac93b23-1041-486e-a16e-861082c92f35"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "034bda10-d48e-449c-9255-247cbf718683"}}}], "length": {"value": 0.00825442, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "923cb400-a742-4e52-948c-6c7d6cb7de45", "name": "l(r:p1rdt6271-p1rdt6274)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a75c5e2-2277-42b4-87d4-6eadff5c06f1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a53624b-8538-4cce-b588-c774875af31b"}}}], "length": {"value": 0.307488, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0a09a81b-a804-4407-b341-726e2c473678", "name": "l(r:p1rdt6270-p1rdt6271)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28954596-f060-4fa8-9f13-dfaa633bb739"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "898611f5-c343-4cca-8e5e-60cf0bfd796b"}}}], "length": {"value": 0.188113, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1369a137-ea26-496f-a49e-07fe1c36db1c"}}}}, {"uuid": "fe825001-39f1-4eda-af62-9c33a676d4b2", "name": "l(r:p1rdt6270-p1rdt6271)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "898611f5-c343-4cca-8e5e-60cf0bfd796b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b81bd5c2-96bb-445e-9eb8-d72360fd8a94"}}}], "length": {"value": 0.0296898, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "adfdca16-9dd2-4e84-828b-3cce8ceeead1", "name": "l(r:p1rdt7564-p1rdt7579)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76f6a27f-0e4f-48b8-9dbd-31c6ffc4ec75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa33ca9e-e16d-4c49-8a70-c6c30cf7b038"}}}], "length": {"value": 0.243188, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e28fa3c8-8478-435b-b24b-b2050db2515d", "name": "l(r:p1rdt7579-p1rdt7588)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76f6a27f-0e4f-48b8-9dbd-31c6ffc4ec75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f2dabc2-0b52-490c-b13a-32c268f6bd33"}}}], "length": {"value": 0.243808, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6c30a9e9-21aa-474e-8386-513a617c20c9", "name": "l(r:p1rdt7554-p1rdt7579)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f6de990-0988-4126-86ca-d1fd72c555fe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76f6a27f-0e4f-48b8-9dbd-31c6ffc4ec75"}}}], "length": {"value": 0.573836, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "558e228e-253b-4a6e-b393-6b01faeae27a", "name": "l(r:p1rdt7554-p1rdt7570)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2bdb2b51-0526-4995-bb5e-a2bd495488d4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f6de990-0988-4126-86ca-d1fd72c555fe"}}}], "length": {"value": 0.0647236, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d49f4c2c-8d0f-47c4-ae4b-a90f17979c57", "name": "l(r:p1rdt7559-p1rdt8015)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f239ef4e-83f0-4a2c-ada3-8e30cef38472"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff343735-753a-48ca-92b1-ea778c9e0b5c"}}}], "length": {"value": 0.10196200000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c0c2911d-ed07-4990-9abb-bc36add87fd0", "name": "l(r:p1rdt7559-p1rdt8015)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff343735-753a-48ca-92b1-ea778c9e0b5c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc543f54-740b-4a7f-b1c5-eb3783a8ade0"}}}], "length": {"value": 0.286466, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b9996b9e-d092-40f7-9d2d-9e261c16d724", "name": "l(r:p1rdt7559-p1rdt7570)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09814176-7891-4fe1-addf-b47aa106c40d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1dbec6c9-5c87-4f56-bd92-4a30d39ad094"}}}], "length": {"value": 0.14637200000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e4a51fb5-8e76-46ef-b920-7b77c5a4d877", "name": "l(r:p1rdt7559-p1rdt7570)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1dbec6c9-5c87-4f56-bd92-4a30d39ad094"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f239ef4e-83f0-4a2c-ada3-8e30cef38472"}}}], "length": {"value": 0.0849739, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1e1ff4ea-e8cd-413e-9ecd-a6b8b712c351", "name": "l(r:p1rdt7552-p1rdt7986)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db899c48-a801-4f83-b59d-e587ba80019d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "93a5388e-ffd7-403e-b6cf-26b7e81feed1"}}}], "length": {"value": 0.384727, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3c9d4cb9-43a5-4fef-a47c-22f1e23a19f3", "name": "l(r:p1rdt7551-p1rdt7552)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f0f3112-1395-48bf-88c1-8dd4b171478d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db899c48-a801-4f83-b59d-e587ba80019d"}}}], "length": {"value": 0.306203, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "887efa1d-3a26-4b29-9ee7-cd4d24b4122f", "name": "l(r:p1rdt7550-p1rdt7561)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc6bd64f-1ad3-4bd9-b590-7d4b673a94b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dead8520-e2f5-499b-9316-77780f9b1dfe"}}}], "length": {"value": 0.102524, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b5dbbf64-d586-472c-be8d-ec4d30c9538a", "name": "l(r:p1rdt8434-p1rdt8450)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f28de397-0db4-486a-8ce6-9f65c68703b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "184f95d4-cde1-4bf1-8a74-ebc7097cb10e"}}}], "length": {"value": 0.130615, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "310b27c0-aeca-4713-8dd9-75634008b0ca", "name": "l(r:p1rdt8434-p1rdt8440)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bbfe31b1-38ce-4ae4-9143-bf08c81617e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f28de397-0db4-486a-8ce6-9f65c68703b3"}}}], "length": {"value": 0.151253, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9d08c952-2d6b-430a-8ac4-049ad384831f", "name": "l(r:p1rdt8436-p1rdt8440)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bbfe31b1-38ce-4ae4-9143-bf08c81617e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "516ca275-0d8e-4a9a-ab59-89cb66b95d93"}}}], "length": {"value": 0.149159, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5ee7bf52-8efb-40b6-af57-c62fd8cd3acf", "name": "l(r:p1rdt8436-p1rdt8440)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "516ca275-0d8e-4a9a-ab59-89cb66b95d93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fcc42825-2690-4965-a99b-e78285a9b84e"}}}], "length": {"value": 0.105337, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "da33cb2a-7eaa-4cfc-9c3d-2a5cb32b1ee0", "name": "l(r:p1rdt8440-p1rdt8444)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bbfe31b1-38ce-4ae4-9143-bf08c81617e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f6e9b43-ceca-4a80-9569-696375a6ff5b"}}}], "length": {"value": 0.189207, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "81cb4004-68fb-40b6-a4c6-ce803572effe", "name": "l(r:p1rdt8440-p1rdt8444)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f6e9b43-ceca-4a80-9569-696375a6ff5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "685fbdbf-47af-4cc2-97ce-354dd04ce915"}}}], "length": {"value": 0.10008, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bc9ceca4-f632-4fd8-a6f7-84e549a2d515", "name": "l(r:p1rdt7555-p1rdt8440)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0075333-98fe-4ee8-bb64-a18119b817c0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bbfe31b1-38ce-4ae4-9143-bf08c81617e8"}}}], "length": {"value": 0.34151, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5f52d5ae-c7f7-405d-8cba-6f26dbf641c4", "name": "l(r:p1rdt7555-p1rdt7561)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc6bd64f-1ad3-4bd9-b590-7d4b673a94b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0075333-98fe-4ee8-bb64-a18119b817c0"}}}], "length": {"value": 0.0383631, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a5a9d7da-14d3-472d-9fbc-553a994c3f7b", "name": "l(r:p1rdt7551-p1rdt7561)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f0f3112-1395-48bf-88c1-8dd4b171478d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e068b84-fbff-4546-b708-ca91ffe92b69"}}}], "length": {"value": 0.124844, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0464cff4-421c-4922-a2f6-94dcd83b1534", "name": "l(r:p1rdt7551-p1rdt7561)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e068b84-fbff-4546-b708-ca91ffe92b69"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc6bd64f-1ad3-4bd9-b590-7d4b673a94b5"}}}], "length": {"value": 0.253169, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6d4670f0-7b81-49d7-8d20-f17d1629268c", "name": "l(r:p1rdt7551-p1rdt7574)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1d8c14d0-8247-4a44-98c1-4534aa9037a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f0f3112-1395-48bf-88c1-8dd4b171478d"}}}], "length": {"value": 0.382752, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "02a59a99-c259-48f2-92be-9d6473e77f82", "name": "l(r:p1rdt7553-p1rdt7572)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddf629eb-ea60-4fce-b731-7ebb33665829"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4307e78-304a-4175-8e81-9cb23d99f394"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0148f62b-4c0b-4711-8743-6575577331b4", "name": "l(r:p1rdt7553-p1rdt7574)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f00dd033-8e7c-43af-bd16-1de2954e07be"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7744d8d9-73a8-4274-9c91-5542620942f5"}}}], "length": {"value": 0.0977575, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "36947727-1aa5-4bcc-be37-bdb16a5a0db9", "name": "l(r:p1rdt7553-p1rdt7574)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7744d8d9-73a8-4274-9c91-5542620942f5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddf629eb-ea60-4fce-b731-7ebb33665829"}}}], "length": {"value": 0.0575736, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "14cc1fc7-59d4-4962-adf6-f9a219e7b2be", "name": "l(r:p1rdt5179-p1rdt6273)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9722136-480b-44cb-8b0e-0b3165712688"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d22f1247-b756-4498-8cf8-fef7d1e859ff"}}}], "length": {"value": 0.33969400000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ba35946f-4710-4036-87d9-e90e0fe76bc3", "name": "l(r:p1rdt8408-p1rdt8458)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28af960e-6f27-483a-8029-0c5f1641f51d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "433162b1-2a9b-4187-ba28-ec57503d76f6"}}}], "length": {"value": 0.0888364, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "71ca0f35-18a0-4a56-a50e-ad4f4c9b6f17", "name": "l(r:p1rdt8408-p1rdt8439)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07f340ca-58c2-4331-8265-a39a45c87b75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3430524c-820d-4f17-ba1b-377aeef4bbcd"}}}], "length": {"value": 0.217599, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "21683217-7a15-47db-8cb9-e443f8569fee", "name": "l(r:p1rdt8408-p1rdt8439)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3430524c-820d-4f17-ba1b-377aeef4bbcd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28af960e-6f27-483a-8029-0c5f1641f51d"}}}], "length": {"value": 0.0862144, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3871706d-53bc-4f3c-887c-1b304b0b5bc9", "name": "l(r:p1rdt6278-p1rdt8439)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19d5304c-574f-4646-8095-d2dcbbea86e7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07f340ca-58c2-4331-8265-a39a45c87b75"}}}], "length": {"value": 0.21709300000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6e3a4316-b83a-4df8-a57c-681507b74e08", "name": "l(r:p1rdt8405-p1rdt8445)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8c69243-872f-4e25-9d03-82692bbf8779"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e3ecdca-4b27-4a9d-8599-637924e86602"}}}], "length": {"value": 0.173131, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "99bc096c-88d2-40dc-84bb-74b6f5ee26b3", "name": "l(r:p1rdt8405-p1rdt8445)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e3ecdca-4b27-4a9d-8599-637924e86602"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc0ee90f-1f9e-435e-bac4-86a4688c48fc"}}}], "length": {"value": 0.152596, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "98f7d539-1e7f-40ee-8dda-dcda64bf53e9", "name": "l(r:p1rdt6500-p1rdt6519)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf648a0d-3262-4150-892b-55c3b117050a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5789c3b2-eb91-4e4c-85e8-24f5893e1a2c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1369a137-ea26-496f-a49e-07fe1c36db1c"}}}}, {"uuid": "daedf677-1099-4aa3-b007-b47edc2916ce", "name": "l(r:p1rdt6505-p1rdt6508)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0824c21-244b-4d4e-85d6-238ac4908b5a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb1c1e50-902d-443d-8c9a-b728d2f6b6f1"}}}], "length": {"value": 0.10179900000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d8c829f8-5194-4cb1-81b5-c3a846ffa9d2", "name": "l(r:p1rdt6510-p1rdt6523)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66b7b2e9-7658-4de0-8197-3829c6179353"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "848c04de-e4d5-4520-9dce-0073776c2ae4"}}}], "length": {"value": 0.167854, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "946d1cc9-2f20-4a54-9480-38deb15660e0", "name": "l(r:p1rdt5730-p1rdt9479)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e07d8bc1-2f8a-4067-a2a7-b903dd042ce3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5897bb2-1f72-4aeb-9090-74e2411b5786"}}}], "length": {"value": 0.30509600000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b0df22f1-d622-429d-8f86-7353e33fde28", "name": "l(r:p1rdt5840-p1rdt9479)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7f9286b-4209-402a-a365-1d27da4efb75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35722d90-049e-4c67-9654-acce0572e6c2"}}}], "length": {"value": 0.269952, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "10ffe1dd-0ef5-4c2b-971d-7dd0c7f0540a", "name": "l(r:p1rdt9298-p1rdt9302)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61ba1001-8b9d-481c-b205-45c6e0beadc1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4a41fe9-62ce-45ba-abcd-086ba429baa0"}}}], "length": {"value": 0.0784931, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b6cf13dc-5432-46f6-8ce7-4dcd6142e06d", "name": "l(r:p1rdt9298-p1rdt9310)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3035d22c-c39f-4f07-9fe9-29888b16057d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61ba1001-8b9d-481c-b205-45c6e0beadc1"}}}], "length": {"value": 0.189404, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ddc2c0a9-cf9d-4540-b621-99c53b060d78", "name": "l(r:p1rdt9310-p1rdt9316)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "644c5887-31f1-436c-bbf6-dae5a70743a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3035d22c-c39f-4f07-9fe9-29888b16057d"}}}], "length": {"value": 0.277772, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4617ca55-9b70-443a-912a-2c0b71d2435e", "name": "l(r:p1rdt9312-p1rdt9316)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "644c5887-31f1-436c-bbf6-dae5a70743a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8721684-5439-482c-b8e5-be330d3cf745"}}}], "length": {"value": 0.433834, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c9872dd4-7084-47d2-9b48-0a683d1d5018", "name": "l(r:p1rdt9311-p1rdt9316)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7011f1dc-1e7d-4961-9a23-620b7f5737af"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "644c5887-31f1-436c-bbf6-dae5a70743a2"}}}], "length": {"value": 0.0277071, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e40bd2c2-6249-4777-9efb-9cafe9e9e47b", "name": "l(r:p1rdt6518-p1rdt9311)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95d939ff-e20d-42b3-bb88-f1975f9fa0aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7011f1dc-1e7d-4961-9a23-620b7f5737af"}}}], "length": {"value": 0.103982, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4149df31-d706-455a-9122-9362e3df9b22", "name": "l(r:p1rdt5729-p1rdt5731)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "77d2122b-cbb7-4844-bbb2-55e939431e50"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52f308f4-35db-49ec-a599-f8380489f952"}}}], "length": {"value": 0.353232, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7b3b465f-dd27-42e7-804a-f97d4617ee2f", "name": "l(r:p1rdt5729-p1rdt5731)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52f308f4-35db-49ec-a599-f8380489f952"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95cd61cf-f1cb-4af2-9d3b-e42978642003"}}}], "length": {"value": 0.0107406, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "709aa023-da9c-4e74-80c6-9ac1241821a6", "name": "l(r:p1rdt5728-p1rdt5729)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b55c58cf-153e-4aa3-b099-8a1db05a6ae5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "77d2122b-cbb7-4844-bbb2-55e939431e50"}}}], "length": {"value": 0.125902, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f75bfbb4-dd53-4f91-99e8-d7364ccf82f6", "name": "l(r:p1rdt5728-p1rdt6537)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66ef2ffb-e67d-47eb-ae59-194c538ab861"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b55c58cf-153e-4aa3-b099-8a1db05a6ae5"}}}], "length": {"value": 0.543863, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b25e1279-aaff-4785-8b93-94d78d7a2bed", "name": "l(r:p1rdt6502-p1rdt9468)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b5695dd-714e-4de1-a63a-f142ff0460e1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e6348d4-7fcb-4546-af84-8ece75b6332f"}}}], "length": {"value": 0.434441, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7d206cf2-ecd2-4567-8615-e996c54cd96c", "name": "l(r:p1rdt6501-p1rdt9468)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddfa01c0-4d12-4f96-ab50-0082ef9914a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e4fd2ed-daa1-4a22-936f-8d51ee928d99"}}}], "length": {"value": 0.099806, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bd9d8818-aa67-4354-b9a9-81d0a90330c9", "name": "l(r:p1rdt6509-p1rdt6514)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42f09ae1-037a-4565-9cd2-0187c45b7866"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0737f6ec-0d5d-4cff-b4b7-9910c7076984"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ca790b78-4e94-4ea4-8d32-da938c5aef92", "name": "l(r:p1rdt6498-p1rdt6516)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60b93cd6-c9fc-46ef-8b37-6b14d0773df6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5c5466f-b7e4-4844-967b-9e8b11c68b44"}}}], "length": {"value": 0.0377529, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "34f48699-c9c2-4f8d-8e66-5822d807e169", "name": "l(r:p1rdt7298-p1rdt7313)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1f6ad7d-f7ea-4b94-956c-ec4a3b2028d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b658bf21-450c-4e6b-9dec-c5023a05fd19"}}}], "length": {"value": 0.0390759, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5d3b1a39-3b9f-43d5-a263-b7e274732cb7", "name": "l(r:p1rdt7036-p1rdt7091)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28d17238-8db8-41da-960c-317183423576"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "770cf0ab-50f1-489b-b2ea-d23ba186d10b"}}}], "length": {"value": 0.10505000000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "85f2d27c-47d3-49d1-9a52-3f41ebb66c72", "name": "l(r:p1rdt7036-p1rdt7091)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "770cf0ab-50f1-489b-b2ea-d23ba186d10b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52068090-b613-46d7-a31f-ad3ca26382d5"}}}], "length": {"value": 0.042633, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "81dd9e15-fe70-4d77-bf53-8ac6b6c4d15b", "name": "l(r:p1rdt7620-p1rdt7627)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97be7ac3-a710-4de8-a666-276813582cd6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5bddd75e-1974-41ee-ab51-625c7485a573"}}}], "length": {"value": 0.0237579, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6bdc087e-f95c-4fbe-bfc6-4a0c6270342d", "name": "l(r:p1rdt7311-p1rdt7620)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3a4dfb4-e1b3-43b9-ae42-b0cec47ff4ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97be7ac3-a710-4de8-a666-276813582cd6"}}}], "length": {"value": 0.142725, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ee2d29a7-a257-4805-9145-9257ecfda11e", "name": "l(r:p1rdt7311-p1rdt9473)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3a4dfb4-e1b3-43b9-ae42-b0cec47ff4ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4d8bafa-711d-4fd7-8374-7eeaeb43edcd"}}}], "length": {"value": 0.0811399, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3efc6b05-eb72-4c79-b237-e882fc3d458c", "name": "l(r:p1rdt7306-p1rdt7311)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "607c7275-da9a-4620-b019-59a66e98c2e6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3a4dfb4-e1b3-43b9-ae42-b0cec47ff4ad"}}}], "length": {"value": 0.0813524, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1ddc01b0-2a75-4050-b3a0-41dcad8ecd63", "name": "l(r:p1rdt7306-p1rdt7626)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "607c7275-da9a-4620-b019-59a66e98c2e6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56d67e3e-46af-4e2c-86a8-191d97b0ce8a"}}}], "length": {"value": 0.166342, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ac22d4a7-8ef7-47a3-8567-dbafa8b1ce03", "name": "l(r:p1rdt7302-p1rdt7306)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a65c4d3-2fc6-48c8-b944-68c4229db3dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "607c7275-da9a-4620-b019-59a66e98c2e6"}}}], "length": {"value": 0.183526, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e036c895-092e-4d78-ae61-8e6f09fca24f", "name": "l(r:p1rdt7302-p1rdt7617)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01c9d31d-c3bb-4950-9bbd-00377c252ddc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a65c4d3-2fc6-48c8-b944-68c4229db3dd"}}}], "length": {"value": 0.047802300000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "70140404-3f92-4e1f-a77d-b86b6a9a60d5", "name": "l(r:p1rdt7617-p1rdt7625)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a11cf3d9-90bb-4de8-b637-6ec9128525ec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01c9d31d-c3bb-4950-9bbd-00377c252ddc"}}}], "length": {"value": 0.0218023, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1f189dee-08e4-4079-bab5-e8a21d66de1f", "name": "l(r:p1rdt7616-p1rdt7630)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "723e2b5c-414c-4f3d-ba23-d2df4bc63e75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7167a2e-9e83-441e-a15b-0256848c3f6d"}}}], "length": {"value": 0.140205, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "fa7dc0a1-b720-42aa-93aa-5e53edf78be1", "name": "l(r:p1rdt7621-p1rdt7630)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa48cf27-3b07-4460-ad9c-8d9862238645"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "723e2b5c-414c-4f3d-ba23-d2df4bc63e75"}}}], "length": {"value": 0.0539367, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c2ab22f8-e100-4ef0-89b3-a41bcc8ad74f", "name": "l(r:p1rdt7621-p1rdt7625)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53df7b6e-bd8c-43f2-860d-8869aec5d079"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa48cf27-3b07-4460-ad9c-8d9862238645"}}}], "length": {"value": 0.18848800000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "771f897b-1f10-40db-b3d7-4066cc1d7638", "name": "l(r:p1rdt7054-p1rdt7090)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08d3a02a-555d-4ad1-9b13-d413b7a16eef"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3cf406b-69e6-4aee-a6fc-272dad7693a4"}}}], "length": {"value": 0.0578677, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "31498136-0f28-4bd8-98f5-9acb29e9649c", "name": "l(r:p1rdt7069-p1rdt7090)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aae22557-7d34-401d-82c9-2d2710ff2915"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08d3a02a-555d-4ad1-9b13-d413b7a16eef"}}}], "length": {"value": 0.128791, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "cdee7d08-5c71-4bf8-a182-b3c06db81686", "name": "l(r:p1rdt7069-p1rdt7087)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f614382d-3883-4f6b-b1f6-c8e83d84ee22"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aae22557-7d34-401d-82c9-2d2710ff2915"}}}], "length": {"value": 0.09476340000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d3bca9dc-c799-419f-9d47-eeac6c2ed7df", "name": "l(r:p1rdt7075-p1rdt7087)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8cebb186-4d9e-4d2c-b0d9-100056d34942"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f614382d-3883-4f6b-b1f6-c8e83d84ee22"}}}], "length": {"value": 0.198314, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1ee5dd7f-8852-4cb7-a544-f046413b4410", "name": "l(r:p1rdt7075-p1rdt7080)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "662e2a1c-9a54-4ac3-b478-98e3a478349d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8cebb186-4d9e-4d2c-b0d9-100056d34942"}}}], "length": {"value": 0.127901, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "389f514c-fe23-4cce-aa69-67e8571eb690", "name": "l(r:p1rdt7080-p1rdt7619)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "161d6f3b-8bd9-4fa8-9442-c6ff008e8d3d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "662e2a1c-9a54-4ac3-b478-98e3a478349d"}}}], "length": {"value": 0.059386400000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4cf5b365-3f96-468a-aeb9-3dcdf312110b", "name": "l(r:p1rdt7615-p1rdt7619)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "161d6f3b-8bd9-4fa8-9442-c6ff008e8d3d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "105df8ff-ec38-4cd6-b557-c318b4023bd0"}}}], "length": {"value": 0.217966, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3231a082-6540-4f71-a015-260c8614cb63", "name": "l(r:p1rdt7619-p1rdt7631)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9e53141-a773-4127-9558-3887070a8f36"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "161d6f3b-8bd9-4fa8-9442-c6ff008e8d3d"}}}], "length": {"value": 0.0570511, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4cc17ad4-3478-4c0c-8565-3dcaeb133743", "name": "l(r:p1rdt7625-p1rdt7631)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "460f5de9-8d4f-468a-b67a-b3b05354a9ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9e53141-a773-4127-9558-3887070a8f36"}}}], "length": {"value": 0.204577, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f8db6b2e-8307-43f8-a986-8c951fc06e7c", "name": "l(r:p1rdt6515-p1rdt6535)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fec078c2-a5d8-4317-a8ac-bc25772f6358"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5a05d0e-8cf2-4ab8-bdfd-24b8cd12ad67"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1369a137-ea26-496f-a49e-07fe1c36db1c"}}}}, {"uuid": "fcee0ed8-6baf-4eef-b433-a2ba9085968a", "name": "l(r:p1rdt6515-p1rdt6536)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04c1e05a-9cbb-4e53-9412-1cffd3976bed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5aa6899b-19a2-41e6-b445-f9fe2536c8d9"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1369a137-ea26-496f-a49e-07fe1c36db1c"}}}}, {"uuid": "16950521-fdd9-46ba-b9eb-d9f5b812710e", "name": "l(r:p1rdt8901-p1rdt8902)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d21061fa-1011-44f7-8a20-26fcf0550f52"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f23ab51c-56f3-4421-b66e-7cdcf109787d"}}}], "length": {"value": 0.309301, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b24e98ec-fd06-44e5-becf-6da45152feab", "name": "l(r:p1rdt7301-p1rdt9377)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61972a50-ce24-4ec1-8535-402665b55a55"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84200441-4c26-4966-a4b7-6b91fb43f02e"}}}], "length": {"value": 0.355831, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "33c4c723-7618-4494-9cf7-a8a01746a442", "name": "l(r:p1rdt8902-p1rdt9377)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43c862de-b014-4b24-8b34-54dae6edcf5a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32e86968-974e-4bcc-b562-1d4209771cf0"}}}], "length": {"value": 0.172034, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "04c8a47f-0b2d-4b5d-af7e-6361e20360cb", "name": "l(r:p1rdt8490-p1rdt9463)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37c41a4b-e439-42a1-b9a7-0582c528f0e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "271ab023-4425-40d8-8080-2481c71309b5"}}}], "length": {"value": 0.21351000000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "83e505b0-a9d8-4e85-ba9c-50cf7624af58", "name": "l(r:p1rdt8490-p1rdt8492)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "307d9c6d-d5ee-4490-95d3-5a9b1d171e54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37c41a4b-e439-42a1-b9a7-0582c528f0e5"}}}], "length": {"value": 0.0991871, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e2567550-8f85-4d77-96b7-a3ef3a0089e0", "name": "l(r:p1rdt7599-p1rdt8492)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "605c34bc-3f7c-4eb7-8df0-fcd00d261921"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3833996b-287c-4a13-9e7c-6834047f3691"}}}], "length": {"value": 1.29606, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5a80d1ee-2c0b-4cff-80ee-f9a438a10bca", "name": "l(r:p1rdt7599-p1rdt8492)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3833996b-287c-4a13-9e7c-6834047f3691"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "307d9c6d-d5ee-4490-95d3-5a9b1d171e54"}}}], "length": {"value": 2.04702, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7d48cc0e-c882-49ae-be92-fe816aa16373", "name": "l(r:p1rdt6226-p1rdt9333)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f6d3fab-3b83-40c9-85c4-cfeddd0d317a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76f24b35-1b82-4760-9817-80c166073f37"}}}], "length": {"value": 0.0994771, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6f3ebb5c-96d5-480e-8403-d35921fdeaae", "name": "l(r:p1rdt6226-p1rdt9333)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76f24b35-1b82-4760-9817-80c166073f37"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d81fc6d7-3400-41d4-91d7-b350d7def98d"}}}], "length": {"value": 0.117787, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5b73908d-2f28-48e9-a7e7-aa024cdccfc5", "name": "l(r:p1rdt5650-p1rdt5662)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36c3c493-ff68-4bb8-a3f4-043c5f847bd3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8f1c67e-9e29-45a3-a2a3-c2f3493a6898"}}}], "length": {"value": 0.373528, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bf809203-3662-4e57-8041-984c2164057f", "name": "l(r:p1rdt5658-p1rdt5663)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81f0e00e-bc49-448a-8e69-0569ed6a8c1a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67d07fb-aec5-4120-8254-32bfcd91e378"}}}], "length": {"value": 0.167002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "83ab7e51-98a6-4e95-b5fa-6c9c2095e331", "name": "l(r:p1rdt5658-p1rdt5663)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67d07fb-aec5-4120-8254-32bfcd91e378"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7356d982-36fd-46cb-9300-8889502e8dc8"}}}], "length": {"value": 0.0344971, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d376dca1-f218-4215-bdc9-4841f949ab27", "name": "l(r:p1rdt7046-p1rdt7067)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b470fa62-70d4-4cc5-8f7e-b9cda37481e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9bb8596a-bcb2-4282-bf1b-9939a9af87d9"}}}], "length": {"value": 0.207649, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "394c4f8d-a10c-4cc7-8d1b-605bc435f8b5", "name": "l(r:p1rdt7038-p1rdt7067)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb3a9847-70d0-4004-95ef-63884c6c1cdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b470fa62-70d4-4cc5-8f7e-b9cda37481e0"}}}], "length": {"value": 0.160885, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5af024a4-176d-4d88-92aa-1cce7304ee2e", "name": "l(r:p1rdt7038-p1rdt7070)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac6e8ccf-75ec-42e0-a3cb-9ab86e2731a4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9cb2d8d-1991-463c-9e6b-88f5624f28c3"}}}], "length": {"value": 0.0923408, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "26068bfb-36ee-4ac3-959b-e22ca0508ad2", "name": "l(r:p1rdt7038-p1rdt7070)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9cb2d8d-1991-463c-9e6b-88f5624f28c3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb3a9847-70d0-4004-95ef-63884c6c1cdc"}}}], "length": {"value": 0.238971, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a443312f-ca47-446d-960f-3de76a23b1f2", "name": "l(r:p1rdt9381-p1rdt9396)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a597011-5e60-46fe-90d6-85728ff0ffa3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5791345-57dc-4f54-ab54-ea63e6a54ee0"}}}], "length": {"value": 0.139587, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bcb59ecd-71f2-4a91-9918-2f6cfe394c47", "name": "l(r:p1rdt7088-p1rdt9396)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac70c13b-5f4f-45f3-880a-b4b476ea552a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a597011-5e60-46fe-90d6-85728ff0ffa3"}}}], "length": {"value": 0.16851400000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f066d9af-3a31-4e4e-9df6-3876ea0e5186", "name": "l(r:p1rdt7088-p1rdt7089)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31cd4834-477f-4060-8efd-0504c8e8eaa9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac70c13b-5f4f-45f3-880a-b4b476ea552a"}}}], "length": {"value": 0.07985440000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "08efaac7-6d95-4425-a194-e9fd5edb3d32", "name": "l(r:p1rdt7061-p1rdt7089)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75947ffd-3765-443b-bef8-b6af746ef624"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "324f5d62-9feb-4fe4-bc1b-3dcf01898148"}}}], "length": {"value": 0.135079, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1a1b0973-d4c6-47d7-8d97-e21a08b578a2", "name": "l(r:p1rdt7061-p1rdt7089)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "324f5d62-9feb-4fe4-bc1b-3dcf01898148"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31cd4834-477f-4060-8efd-0504c8e8eaa9"}}}], "length": {"value": 0.18246, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "552b8434-b608-4927-a5b9-ea068ccdc34d", "name": "l(r:p1rdt7061-p1rdt7070)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac6e8ccf-75ec-42e0-a3cb-9ab86e2731a4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84578de8-d5de-41fe-b637-42425e97b7db"}}}], "length": {"value": 0.128507, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3459416c-f085-4e60-9593-ce3b3585f76c", "name": "l(r:p1rdt7061-p1rdt7070)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84578de8-d5de-41fe-b637-42425e97b7db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75947ffd-3765-443b-bef8-b6af746ef624"}}}], "length": {"value": 0.322501, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a1c26b2c-7b4a-4027-88a6-1cbb94147d65", "name": "l(r:p1rdt5658-p1rdt7070)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02407b52-58c3-403c-9b5b-38695f435476"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac6e8ccf-75ec-42e0-a3cb-9ab86e2731a4"}}}], "length": {"value": 0.61978, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4c909e74-bd70-48ae-b4b9-fa6c0f49c742", "name": "l(r:p1rdt5017-p1rdt5200)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0843e99-e917-473c-bec7-ee0c3ddec601"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "799ab435-c0a4-4515-8125-e8ca2fb7632d"}}}], "length": {"value": 0.234989, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3904e139-a874-4ec4-b65c-f1113096a4b4", "name": "l(r:p1rdt7576-p1rdt8422)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b28595b-dcbe-4d1b-92c4-94acf370bb1f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ce65512-7d5f-4514-b55c-1775e80dd94d"}}}], "length": {"value": 0.0564986, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "91556012-ddc5-4cf8-828a-a6303f5cb1bd", "name": "l(r:p1rdt7576-p1rdt8151)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a31fa2-4df8-418a-a215-d0d450ced9a3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df71ab4b-258c-4812-9537-6d425bacb468"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "96c8992e-ab08-485e-8757-96b0e71fedc8", "name": "l(r:p1rdt7576-p1rdt8151)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df71ab4b-258c-4812-9537-6d425bacb468"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c951cf67-3297-407f-805c-55d9c03fb519"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "75782f97-8d8e-4957-97f0-8e2dabe321d9", "name": "l(r:p1rdt7576-p1rdt8151)_s2", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c951cf67-3297-407f-805c-55d9c03fb519"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b28595b-dcbe-4d1b-92c4-94acf370bb1f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7c6ac7b6-d8d7-455b-817c-4553072e5c9a", "name": "l(r:p1rdt8149-p1rdt8155)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1613a53e-5194-4d26-b83b-475d9f02a32c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b706c56-20f1-49ed-9cbe-0ec1491b83e0"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "40a5a234-9d35-48aa-8436-976911dc216f", "name": "l(r:p1rdt5153-p1rdt8441)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b423745-cc70-4c3a-adb0-f648170b4ab1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dac2cb8c-428b-49c4-8368-35608c050390"}}}], "length": {"value": 0.190536, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "cf871f54-cd17-4e6e-b56a-680cb64f1680", "name": "l(r:p1rdt5153-p1rdt8441)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dac2cb8c-428b-49c4-8368-35608c050390"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dff898c1-a386-4219-9e8d-2d08b49f9098"}}}], "length": {"value": 0.26071, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b28e3e27-9c0e-4a4e-89c9-565fdc854f99", "name": "l(r:p1rdt5153-p1rdt8441)_s2", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dff898c1-a386-4219-9e8d-2d08b49f9098"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb8dae66-287a-4b8a-9cda-6ae02cb8f8a9"}}}], "length": {"value": 0.128532, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "21a471ec-3f91-4bac-9f9c-2f63f39e7608", "name": "l(r:p1rdt8150-p1rdt8441)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78081763-07d2-4989-b492-e1c5178c4097"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83b76782-be09-4733-a35c-6f3f26059a4d"}}}], "length": {"value": 0.16747, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "59606c40-3050-4e1f-84d7-b3adeab006eb", "name": "l(r:p1rdt8150-p1rdt8441)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83b76782-be09-4733-a35c-6f3f26059a4d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b423745-cc70-4c3a-adb0-f648170b4ab1"}}}], "length": {"value": 0.585344, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9390eaa1-85ed-427d-b557-87485f68297d", "name": "l(r:p1rdt8150-p1rdt8442)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78081763-07d2-4989-b492-e1c5178c4097"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2ef098d-d7e6-4530-a5cc-b6472ec9ffdc"}}}], "length": {"value": 0.219381, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ae6dfad9-4b8b-4567-beea-e08350b422f2", "name": "l(r:p1rdt8150-p1rdt8442)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2ef098d-d7e6-4530-a5cc-b6472ec9ffdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6700763-e6dc-4626-ac2b-22985f0043be"}}}], "length": {"value": 0.29839800000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9914a6ee-984e-4689-83bb-a541dd092fc7", "name": "l(r:p1rdt8150-p1rdt8155)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1613a53e-5194-4d26-b83b-475d9f02a32c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b7280d1f-5ff9-45ee-9949-ecc70509a2a1"}}}], "length": {"value": 0.0723619, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "deed0a14-e67a-4500-9626-be034c9a20fa", "name": "l(r:p1rdt8150-p1rdt8155)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b7280d1f-5ff9-45ee-9949-ecc70509a2a1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78081763-07d2-4989-b492-e1c5178c4097"}}}], "length": {"value": 0.0446835, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8f14f92d-f5a4-4941-a518-79a7131e3bdd", "name": "l(r:p1rdt8155-p1rdt8157)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1613a53e-5194-4d26-b83b-475d9f02a32c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a30e197-897f-4516-b4e5-f70081e6f8c7"}}}], "length": {"value": 0.11694, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c9ae81de-99a7-45de-8eae-0dc8d72eb86c", "name": "l(r:p1rdt8151-p1rdt8155)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0a6628e-afc1-4daf-8a29-7626ac2aa5dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1613a53e-5194-4d26-b83b-475d9f02a32c"}}}], "length": {"value": 0.09203890000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "17a9aea4-714b-4a9e-bc93-6d59c828ea03", "name": "l(r:p1rdt5481-p1rdt5483)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f903015c-95a7-4d6e-b2a5-e9705c050c6e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d29d8b74-a24d-4474-9752-c1ffa1aa7f7c"}}}], "length": {"value": 0.218893, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bc927f95-acf8-4e59-9de3-a63c5a83649d", "name": "l(r:p1rdt5480-p1rdt5483)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2568f11c-8a37-4a55-8bce-9f0d56ac386a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f903015c-95a7-4d6e-b2a5-e9705c050c6e"}}}], "length": {"value": 0.0194577, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "dcc2039e-e644-4d69-b245-4b2970b5781d", "name": "l(r:p1rdt5477-p1rdt5480)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7d7f462-1ab5-4fd8-baaa-7e576eead5c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2568f11c-8a37-4a55-8bce-9f0d56ac386a"}}}], "length": {"value": 0.05838600000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "16f55ad7-24d9-4ec0-8729-a3f0c865164a", "name": "l(r:p1rdt5477-p1rdt7201)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7d7f462-1ab5-4fd8-baaa-7e576eead5c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df1d5615-4a0b-4041-8940-f13de9f7036a"}}}], "length": {"value": 0.101327, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "cb4e31da-15dd-4846-95b9-04865a0bcc59", "name": "l(r:p1rdt5477-p1rdt7201)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df1d5615-4a0b-4041-8940-f13de9f7036a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f64ed4a2-6afb-447c-8c6b-15935e050a6d"}}}], "length": {"value": 0.0635197, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1e1f4f6c-9c9c-4c7c-afa2-84cde862974f", "name": "l(r:p1rdt5472-p1rdt5477)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a8c3f7f-b9be-4c5e-b6f0-8f2fc18935fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "595463a5-2019-4c94-b72d-c824c2aef347"}}}], "length": {"value": 0.182509, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "436ac0bd-b246-48ce-94e1-7b1b0df0c7c7", "name": "l(r:p1rdt5472-p1rdt5477)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "595463a5-2019-4c94-b72d-c824c2aef347"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7d7f462-1ab5-4fd8-baaa-7e576eead5c7"}}}], "length": {"value": 0.00190877, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c20d723c-25d6-4888-b6f4-97cc3e392f79", "name": "l(r:p1rdt5472-p1rdt5476)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d69527e6-70b6-43e2-8b9e-7c8570ad5ddf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a8c3f7f-b9be-4c5e-b6f0-8f2fc18935fa"}}}], "length": {"value": 0.464713, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ac8991d3-6d78-4983-999e-61a1df7121c2", "name": "l(r:p1rdt7704-p1rdt9266)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02ea9067-6a2a-48b6-b5f1-10992b9fbd77"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f633393e-4d67-4646-838b-14f25641b426"}}}], "length": {"value": 0.327122, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "63d17b30-daf0-4906-8098-2e394c28e221", "name": "l(r:p1rdt7704-p1rdt9266)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f633393e-4d67-4646-838b-14f25641b426"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fbb2bd0-d109-4248-85f3-266fe479677f"}}}], "length": {"value": 0.119759, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "91bc4b46-c695-480b-858f-4fb349c9f026", "name": "l(r:p1rdt7704-p1rdt7712)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4462b9c6-748f-48e9-9ff9-7f20a06cf456"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02ea9067-6a2a-48b6-b5f1-10992b9fbd77"}}}], "length": {"value": 0.290826, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "74871719-24e2-4446-a5c1-6607bc9b6bd2", "name": "l(r:p1rdt7712-p1rdt7718)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4462b9c6-748f-48e9-9ff9-7f20a06cf456"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "048e2bab-67f2-4975-81a1-bbc9f2f9cd88"}}}], "length": {"value": 0.315016, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8fb5ae90-d852-4217-8ad8-7e35ff1771ef", "name": "l(r:p1rdt7701-p1rdt7712)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "74968ebc-53c5-4fc6-8172-3ffa9dea7683"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4462b9c6-748f-48e9-9ff9-7f20a06cf456"}}}], "length": {"value": 0.0526994, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "764fe5e3-4f60-49ac-b40e-80e11eef2a63", "name": "l(r:p1rdt7699-p1rdt7701)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec849ee4-3d69-46a9-9a2a-242a3943e46c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "74968ebc-53c5-4fc6-8172-3ffa9dea7683"}}}], "length": {"value": 0.0894152, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "948e03e5-6f8e-4e2a-b745-53bc7ae9fb10", "name": "l(r:p1rdt5485-p1rdt7699)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cfb3a23-3a93-4d89-8b70-e4730ebbce1a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "890cd47a-994b-4dca-8d59-25164f04c927"}}}], "length": {"value": 0.126204, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "432a59ab-ea4f-45fb-b79f-173e74a857ab", "name": "l(r:p1rdt5485-p1rdt7699)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "890cd47a-994b-4dca-8d59-25164f04c927"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec849ee4-3d69-46a9-9a2a-242a3943e46c"}}}], "length": {"value": 0.179947, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e51e0264-f754-45e2-a1b3-933e30c3cd56", "name": "l(r:p1rdt5475-p1rdt5485)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b9e57e0-6dc8-4831-ac7d-36f8608b7a8d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cfb3a23-3a93-4d89-8b70-e4730ebbce1a"}}}], "length": {"value": 0.0575139, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ecfbc31a-21c6-47a5-a744-7345eb49ee1e", "name": "l(r:p1rdt5475-p1rdt5476)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae343ca3-3337-4528-b117-38a51e6d023f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b9e57e0-6dc8-4831-ac7d-36f8608b7a8d"}}}], "length": {"value": 0.453804, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0dfee531-83f3-4357-8062-4451c875f683", "name": "l(r:p1rdt5476-p1rdt5478)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c977e6c-43f0-4d7e-b19f-82f0de97dab2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a97491e-2c98-4584-9b74-5593f17faeda"}}}], "length": {"value": 0.3849, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "63f4017a-0e53-4030-9f03-15546872260d", "name": "l(r:p1rdt6848-p1rdt9264)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96399e51-1243-4e7f-ae3a-5e2c67123aae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b764d22-debb-4d88-8221-ff79307e609f"}}}], "length": {"value": 0.24693, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "62ef9b36-dcd1-4bc0-907a-675b87e52164", "name": "l(r:p1rdt6848-p1rdt9264)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b764d22-debb-4d88-8221-ff79307e609f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bdf3994-bb0c-44f4-b1ea-ab29e73bd39c"}}}], "length": {"value": 0.116892, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3b953a51-c8a1-4a38-8773-f8a7016dfcbf", "name": "l(r:p1rdt6847-p1rdt6848)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e92b102-eaee-41cc-a2fc-c6c4b3bfb58b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96399e51-1243-4e7f-ae3a-5e2c67123aae"}}}], "length": {"value": 0.92611, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "480f3768-51e4-48e1-a449-a533eb206658", "name": "l(r:p1rdt6847-p1rdt7624)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be9350ab-7ad2-4a89-a374-94bf69588d7f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e92b102-eaee-41cc-a2fc-c6c4b3bfb58b"}}}], "length": {"value": 0.622643, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "2792a58e-fa63-427d-950f-9719c7fa27ea", "name": "l(r:p1rdt6348-p1rdt6350)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d6c5b78-35c4-475a-8837-776dea236c95"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c935f1c0-e36c-407d-a2e8-4181c4b0733e"}}}], "length": {"value": 0.150337, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bdb40655-4f94-4583-af63-540676cc787b", "name": "l(r:p1rdt6345-p1rdt6348)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40280da5-767c-4610-b6a8-ff411e1c33e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d6c5b78-35c4-475a-8837-776dea236c95"}}}], "length": {"value": 0.368527, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "50411b97-2ca0-4fd4-a03d-cd1d5a15d841", "name": "l(r:p1rdt6345-p1rdt6356)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1bdfc1ac-98a4-43dd-bb2c-837d0a2c15f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40280da5-767c-4610-b6a8-ff411e1c33e8"}}}], "length": {"value": 0.463971, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9944e15d-1d1f-4de2-b2d7-73810d8a552e", "name": "l(r:p1rdt6353-p1rdt6356)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1bdfc1ac-98a4-43dd-bb2c-837d0a2c15f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e51e0d9-24b6-40ac-859a-51ea74c93e76"}}}], "length": {"value": 0.407215, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "73284547-7d9c-4518-b0b1-abc15099090f", "name": "l(r:p1rdt6354-p1rdt6356)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1bdfc1ac-98a4-43dd-bb2c-837d0a2c15f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2040b1a2-85bc-405a-9dab-138561b5e3ac"}}}], "length": {"value": 0.108189, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6396a12f-73d3-4220-acb6-ffb04d2fd93a", "name": "l(r:p1rdt6354-p1rdt6356)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2040b1a2-85bc-405a-9dab-138561b5e3ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a05e7c9-4bff-46fd-b356-8120b481b053"}}}], "length": {"value": 0.017765, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d633367e-1657-4af7-9dfa-e9d06c37122b", "name": "l(r:p1rdt6347-p1rdt6356)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7166849-6ecd-4270-bf52-d0579838336a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1bdfc1ac-98a4-43dd-bb2c-837d0a2c15f9"}}}], "length": {"value": 0.633788, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5911af5d-66da-477a-9570-565ddc5292fb", "name": "l(r:p1rdt7598-p1rdt7605)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e36f1f1-6993-46b0-bafa-9530fd1652ef"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f95e5fa5-a84c-42a4-b519-8d344e816ecd"}}}], "length": {"value": 0.10583000000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "dd01fae1-634b-400c-a135-5dd7242a7e81", "name": "l(r:p1rdt7589-p1rdt7605)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f9809eb-41e0-40a8-b43a-93556f767f68"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e36f1f1-6993-46b0-bafa-9530fd1652ef"}}}], "length": {"value": 0.43683900000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1441ec02-dff2-4e01-af50-3ee3779998cb", "name": "l(r:p1rdt7589-p1rdt7612)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f9809eb-41e0-40a8-b43a-93556f767f68"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3410d88a-3e9c-427e-a79e-5c602455ed1d"}}}], "length": {"value": 0.525437, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "58ab57ef-9ed9-40ab-a4a0-72c5c4f3b6f6", "name": "l(r:p1rdt6347-p1rdt7589)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7166849-6ecd-4270-bf52-d0579838336a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f9809eb-41e0-40a8-b43a-93556f767f68"}}}], "length": {"value": 0.816381, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d601e0c8-87fa-4c4d-91e4-db629622c5ab", "name": "l(r:p1rdt6347-p1rdt8470)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6163371c-55ef-4900-a3ef-2e4e8fc2894a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7166849-6ecd-4270-bf52-d0579838336a"}}}], "length": {"value": 1.6455, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f9d802d6-7774-4bcd-92c8-41fed7e7cdec", "name": "l(r:p1rdt5218-p1rdt5653)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "769c14db-ac3f-438d-9f7d-c7eb2d3074b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98f2c16a-cdbd-49a3-b60d-4be6e9158480"}}}], "length": {"value": 0.123439, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ebc30854-15d0-4059-a4e4-a3b1a8071a39", "name": "l(r:p1rdt5218-p1rdt5653)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98f2c16a-cdbd-49a3-b60d-4be6e9158480"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dda7f7c-3b21-46a0-88a3-2b7f028b7772"}}}], "length": {"value": 0.122523, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4714a056-deff-4fcb-be44-1619b12bc118", "name": "l(r:p1rdt5195-p1rdt5653)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58c6d858-d457-4fe6-a45b-b9b2b73cad8c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fbc486eb-4f08-4602-a101-1298d4a46b32"}}}], "length": {"value": 0.10076600000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "242b9fb2-b832-46a9-b745-db7185470528", "name": "l(r:p1rdt6995-p1rdt7015)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3741c9d4-d03a-4b2f-be57-52a8977351ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d4d11a9-8de3-4dbe-8974-6005ed40f363"}}}], "length": {"value": 0.232606, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "699b5de4-087d-4717-9489-fb69e110294a", "name": "l(r:p1rdt6995-p1rdt7015)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d4d11a9-8de3-4dbe-8974-6005ed40f363"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6278a0d-f5d3-4b11-aee9-3bb23f9954a8"}}}], "length": {"value": 0.0860291, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f53d6c08-324f-49c9-9c3e-83864f308dc5", "name": "l(r:p1rdt16638-p1rdt16725)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c0d417e-c787-4b0a-a39e-b19ef274b36b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2d0eb0b-bbb6-4b3e-bdc6-4c8a0e7d466f"}}}], "length": {"value": 0.163486, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "176d8831-9ba5-4d7b-865b-99ea7e6aa381", "name": "l(r:p1rdt16638-p1rdt6995)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3741c9d4-d03a-4b2f-be57-52a8977351ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddb8e50b-2619-4e74-aee6-84dc4e11389e"}}}], "length": {"value": 0.166099, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b817c266-305b-4ad6-afa6-cdbd5b7def69", "name": "l(r:p1rdt16638-p1rdt6995)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddb8e50b-2619-4e74-aee6-84dc4e11389e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c0d417e-c787-4b0a-a39e-b19ef274b36b"}}}], "length": {"value": 4.23424, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "045afc0b-2012-4ca8-a295-71783d57d765", "name": "l(r:p1rdt5195-p1rdt6995)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58c6d858-d457-4fe6-a45b-b9b2b73cad8c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9056795d-5c81-4fb9-96bc-51d63b32b187"}}}], "length": {"value": 0.168784, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6a994cb4-f5f1-4df2-8d5e-c05435989755", "name": "l(r:p1rdt5195-p1rdt6995)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9056795d-5c81-4fb9-96bc-51d63b32b187"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3741c9d4-d03a-4b2f-be57-52a8977351ad"}}}], "length": {"value": 0.659388, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5c99986b-343d-4b8d-beb5-8d646498648b", "name": "l(r:p1rdt5195-p1rdt5202)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "227d848c-cddc-4561-996b-f8f7a60a5a89"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43e1b69a-c6dd-447e-82d9-921998de9837"}}}], "length": {"value": 0.168993, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bce828da-59ac-4d79-a897-197182228522", "name": "l(r:p1rdt5195-p1rdt5202)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43e1b69a-c6dd-447e-82d9-921998de9837"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e2f2704-4dee-4c78-b199-256b907156f3"}}}], "length": {"value": 0.111644, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "459455e3-ceff-404b-b7ce-cf80495c6db9", "name": "l(r:p1rdt5195-p1rdt5202)_s2", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e2f2704-4dee-4c78-b199-256b907156f3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58c6d858-d457-4fe6-a45b-b9b2b73cad8c"}}}], "length": {"value": 0.284889, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "14d0c4b1-b98e-469a-a68c-82291e282126", "name": "l(r:p1rdt5202-p1rdt5206)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97e4f179-9d60-4183-8326-eb0ab98a53eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17fedb14-6008-43fd-b7e9-342a113f27a6"}}}], "length": {"value": 0.19259500000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5b4278e7-9191-458b-b6c3-fcf736f69eaa", "name": "l(r:p1rdt5202-p1rdt5206)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17fedb14-6008-43fd-b7e9-342a113f27a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ed081eb-6b56-43b8-9cf8-e7ffdd8222f2"}}}], "length": {"value": 0.0669161, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "45ad7777-5030-4f58-baee-e3f8ffdcaa71", "name": "l(r:p1rdt5202-p1rdt7268)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a21680f1-33a7-44e1-9293-98c6861ba2a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6e61d2f-f75e-4335-aec9-4722942be9f1"}}}], "length": {"value": 0.301796, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5edc97b2-39e7-4ad3-89c4-4701b2b65678", "name": "l(r:p1rdt5202-p1rdt7268)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6e61d2f-f75e-4335-aec9-4722942be9f1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97e4f179-9d60-4183-8326-eb0ab98a53eb"}}}], "length": {"value": 1.26696, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7dcb8149-48f5-40b6-8bf7-d2a9a285cc09", "name": "l(r:p1rdt6349-p1rdt6355)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "88cc1382-6b14-4500-8a21-662fce6a0c0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c1edcfa-e0e4-4493-a9bb-e6033185ce67"}}}], "length": {"value": 0.0974401, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e157dc9b-2c86-419e-b934-ef99e273990b", "name": "l(r:p1rdt6355-p1rdt7224)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eeab7dfa-540c-4275-b159-f6ac4d1350f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "88cc1382-6b14-4500-8a21-662fce6a0c0b"}}}], "length": {"value": 0.455366, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4cbbff52-c85f-4eb7-b673-68e04d17547b", "name": "l(r:p1rdt7224-p1rdt7618)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eeab7dfa-540c-4275-b159-f6ac4d1350f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0fef9b3-a4bd-421c-8a54-cbf6f44c460d"}}}], "length": {"value": 0.282912, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d47ed6f4-4d52-4f70-a3e9-8fc6abdfb2c8", "name": "l(r:p1rdt7224-p1rdt7268)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a21680f1-33a7-44e1-9293-98c6861ba2a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22978d10-c9dc-4c84-8025-5749c730daa6"}}}], "length": {"value": 0.593134, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "2804c4ab-653b-4383-9793-17d37549fd78", "name": "l(r:p1rdt7224-p1rdt7268)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22978d10-c9dc-4c84-8025-5749c730daa6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eeab7dfa-540c-4275-b159-f6ac4d1350f9"}}}], "length": {"value": 0.197971, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c8da4fda-f3b6-4e5e-80ad-e99478be3bf2", "name": "l(r:p1rdt7268-p1rdt8470)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6225b33-2abc-4f77-9d65-459794f56353"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a21680f1-33a7-44e1-9293-98c6861ba2a5"}}}], "length": {"value": 1.40851, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8da487d2-4b45-4418-bfbc-c0dea1344931", "name": "l(r:p1rdt7735-p1rdt7790)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97198258-8ba3-4950-8747-3241c6a4fcee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62078787-3ae2-47b3-8f67-8e89e110c8be"}}}], "length": {"value": 0.206801, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f413d80b-c84b-4b47-b903-13ba7aaeb14e", "name": "l(r:p1rdt7790-p1rdt9090)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15a7847f-aa96-4206-b4c6-422802f4e0a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97198258-8ba3-4950-8747-3241c6a4fcee"}}}], "length": {"value": 0.246196, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "280746d1-8633-4f46-b5b2-5c3366afa2a9", "name": "l(r:p1rdt8911-p1rdt9384)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26613f51-86bf-4ae1-86c0-f23e48cf606e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7bc7d623-3ca7-4c4e-b11c-f373e90d06b6"}}}], "length": {"value": 0.11493, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4ea02402-fbd7-4f93-a5b3-87c7cba41c90", "name": "l(r:p1rdt8911-p1rdt9384)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7bc7d623-3ca7-4c4e-b11c-f373e90d06b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6eb9c7a5-5ab1-4d9b-a59e-538b68ad0bb9"}}}], "length": {"value": 0.0369839, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "76520eb4-9022-455a-95e2-68615f432757", "name": "l(r:p1rdt8905-p1rdt8911)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "924fc042-6ddc-484b-b09f-c65b35817d25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26613f51-86bf-4ae1-86c0-f23e48cf606e"}}}], "length": {"value": 0.148702, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "fe8ce15c-6fbe-4020-8e5d-d64427fd1c55", "name": "l(r:p1rdt8904-p1rdt8916)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "adcc33f8-72a3-434c-a021-6c5973713a91"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5584edfb-c31e-4e1d-87d3-b8161a59b15b"}}}], "length": {"value": 0.119301, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f35e4490-62b3-46a0-bb93-7194613325c6", "name": "l(r:p1rdt8904-p1rdt8916)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5584edfb-c31e-4e1d-87d3-b8161a59b15b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2edd17c2-6dfb-4f86-8998-b90a99755e96"}}}], "length": {"value": 0.0388388, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0d648254-33db-4f6c-b1a3-a5eb565882e2", "name": "l(r:p1rdt8905-p1rdt8916)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "924fc042-6ddc-484b-b09f-c65b35817d25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "adcc33f8-72a3-434c-a021-6c5973713a91"}}}], "length": {"value": 0.1748, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1f0641a1-24a2-44f6-a540-19f1d775a311", "name": "l(r:p1rdt8905-p1rdt8915)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "361385c6-bb6d-4bbc-ab7d-4a5774e03d82"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "924fc042-6ddc-484b-b09f-c65b35817d25"}}}], "length": {"value": 0.0903932, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "02e7d66a-a59b-4e2b-a49f-babf0eed8b45", "name": "l(r:p1rdt6574-p1rdt8915)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25a9ec20-35b9-4262-a02d-cafa63e5ee42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9ef9958-5d9e-4907-91cd-4c5d099daaf1"}}}], "length": {"value": 0.200113, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "01105eeb-78ae-43ca-8fef-2d73d4dd9715", "name": "l(r:p1rdt6574-p1rdt8915)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9ef9958-5d9e-4907-91cd-4c5d099daaf1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "361385c6-bb6d-4bbc-ab7d-4a5774e03d82"}}}], "length": {"value": 0.502215, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8fd323f7-0f6a-46f6-992e-bf7620907a90", "name": "l(r:p1rdt6574-p1rdt6581)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "599c6ed9-5ff7-4c97-a469-adceecaaf902"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25a9ec20-35b9-4262-a02d-cafa63e5ee42"}}}], "length": {"value": 0.214792, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5c51619f-c22d-4bab-88b1-5e86c6461402", "name": "l(r:p1rdt6581-p1rdt9084)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6114624f-81c8-4d9c-8f9a-3ab73158596e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "599c6ed9-5ff7-4c97-a469-adceecaaf902"}}}], "length": {"value": 0.220787, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8f71b6b2-940e-460b-aca1-395123d090d7", "name": "l(r:p1rdt9076-p1rdt9093)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2ce5116-c4f0-4ac7-a34f-3ba44c99d04b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c29179f3-0b4e-449c-8562-a8fcb675be6c"}}}], "length": {"value": 0.0790457, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "10112fc8-0706-4ca6-a9dc-155f2b62b426", "name": "l(r:p1rdt9076-p1rdt9084)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12b4dc99-fe50-457c-90aa-48a2fb19ebf1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2ce5116-c4f0-4ac7-a34f-3ba44c99d04b"}}}], "length": {"value": 0.143642, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7a562dd7-062c-47c7-a967-a36881222871", "name": "l(r:p1rdt9085-p1rdt9091)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "563c6bb3-d8ed-4fce-ad66-3892426248df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7fcdf409-885c-4c95-834e-988842ed3f5c"}}}], "length": {"value": 0.037383000000000007, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "816469ff-5ef9-491d-a0e5-f0cd167e7249", "name": "l(r:p1rdt9090-p1rdt9091)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf719d10-8168-4d80-894e-1b1516f033e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "563c6bb3-d8ed-4fce-ad66-3892426248df"}}}], "length": {"value": 0.176401, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f21c5d48-35f7-48b8-b0e3-e303cb6e0d3a", "name": "l(r:p1rdt9469-p1rdt9470)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5f6a2ec-3ddd-4ba7-9c55-88b4d82e7735"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acf91e46-ba32-44c3-a829-14c80a693d7d"}}}], "length": {"value": 0.0968012, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4f55c8b3-52d9-48bd-80b9-4336d109293f", "name": "l(r:p1rdt5140-p1rdt5184)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "431b672b-cb45-4294-b1f9-1d63f4efc8db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ceb58d66-3cb3-416d-aedf-f4949432eb37"}}}], "length": {"value": 0.11451800000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "87ff4d03-1265-417f-8396-f2223bf91dc2", "name": "l(r:p1rdt5140-p1rdt5184)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ceb58d66-3cb3-416d-aedf-f4949432eb37"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b0fd055-d0ac-4678-a8e5-679e12741736"}}}], "length": {"value": 0.0332053, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "049715c6-15cd-4adc-bfcb-405451aa8567", "name": "l(r:p1rdt5154-p1rdt5184)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50332aed-ecfd-465a-977e-c24ed6462860"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "431b672b-cb45-4294-b1f9-1d63f4efc8db"}}}], "length": {"value": 0.120991, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "76f0c663-18fa-4b81-a500-c47e1e85102e", "name": "l(r:p1rdt5142-p1rdt5154)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d579047b-82f6-49bf-bd7b-28c818d44bb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50332aed-ecfd-465a-977e-c24ed6462860"}}}], "length": {"value": 0.334614, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "756d1a3b-80d5-45f2-b945-05ac9c864cc7", "name": "l(r:p1rdt5142-p1rdt5180)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d579047b-82f6-49bf-bd7b-28c818d44bb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6316fa2-dd57-46d4-89c0-f11dd675d686"}}}], "length": {"value": 0.304739, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "23f00fb1-3a44-456d-adfc-200b1c385382", "name": "l(r:p1rdt5142-p1rdt8414)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b48f78d-1092-4536-bfb3-029da6a70dff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50f71b3d-83ce-4526-8057-4a38042b7295"}}}], "length": {"value": 0.0685574, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "e62ca4d7-5c98-4352-9f1d-520696b1d502", "name": "l(r:p1rdt5142-p1rdt8414)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50f71b3d-83ce-4526-8057-4a38042b7295"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d579047b-82f6-49bf-bd7b-28c818d44bb3"}}}], "length": {"value": 0.517385, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "591186a8-ed4e-49a7-a103-b77dc41ee44c", "name": "l(r:p1rdt6409-p1rdt8414)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42929633-40d4-4e13-a0aa-a7682f328226"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8648275-54c9-48e3-82e0-33119313924d"}}}], "length": {"value": 0.184195, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "712a1997-2d23-4337-adc2-b4f3245b7797", "name": "l(r:p1rdt6409-p1rdt8414)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8648275-54c9-48e3-82e0-33119313924d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b48f78d-1092-4536-bfb3-029da6a70dff"}}}], "length": {"value": 0.718647, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "40a640c0-70ae-4ede-af89-011fe2f9c3d6", "name": "l(r:p1rdt6409-p1rdt9413)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f750e531-5ade-40a9-9bb0-042220ce9807"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42929633-40d4-4e13-a0aa-a7682f328226"}}}], "length": {"value": 1.30529, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "9557eec3-679c-4760-af42-931b0ecaf811", "name": "l(r:p1rdt7570-p1rdt7574)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9b94106-b7c5-4ce9-9c19-053487848c2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd487832-bc77-406f-a995-4b099fad7c64"}}}], "length": {"value": 0.145959, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "4d38ea75-cd04-43b1-8a35-82c9b0e08cfb", "name": "l(r:p1rdt6275-p1rdt7570)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08d4c459-5bc5-4cad-8e74-613c4a08cb35"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9b94106-b7c5-4ce9-9c19-053487848c2a"}}}], "length": {"value": 0.362236, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "2e63b32d-43ae-42f8-bfbc-1179dc97926a", "name": "l(r:p1rdt6270-p1rdt6275)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cf36152-b3af-49f7-b693-5d465db1f283"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08d4c459-5bc5-4cad-8e74-613c4a08cb35"}}}], "length": {"value": 0.224093, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "a4f133cd-d305-41fc-9adf-8e347daa1943", "name": "l(r:p1rdt6269-p1rdt6270)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5ef97a6-6c60-46eb-acce-6469b273658a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cf36152-b3af-49f7-b693-5d465db1f283"}}}], "length": {"value": 0.284296, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "03db94ff-d792-433b-a8ab-a92dd86752d7", "name": "l(r:p1rdt6269-p1rdt8405)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60829dab-c129-4017-961a-81435d8afa93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5ef97a6-6c60-46eb-acce-6469b273658a"}}}], "length": {"value": 0.466915, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "afade1f8-1732-423e-b3af-635852b088ba", "name": "l(r:p1rdt8405-p1rdt9413)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16ecb938-cd0c-4be5-a915-be0d84d351f2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60829dab-c129-4017-961a-81435d8afa93"}}}], "length": {"value": 1.34967, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "aabe9c80-a880-4171-a383-28382ce12704", "name": "l(r:p1rdt6518-p1rdt9314)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d25f8d60-8aa7-4975-96dc-eba7696fa8ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d39c608-5688-4e22-8ac4-96b896265274"}}}], "length": {"value": 0.0596908, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "c08967c9-6afc-4436-b958-5f3dec162e2a", "name": "l(r:p1rdt9314-p1rdt9479)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b006c3-79f8-4a27-b76a-d1b458ff2a21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d25f8d60-8aa7-4975-96dc-eba7696fa8ae"}}}], "length": {"value": 0.23881800000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d9a45f7b-94cd-476f-b492-6be6d2c3273f", "name": "l(r:p1rdt6539-p1rdt9479)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9707f264-8f82-4483-8337-6c89d709faf7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b006c3-79f8-4a27-b76a-d1b458ff2a21"}}}], "length": {"value": 0.04213, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "5b6a5df1-5751-419e-9043-c59af2cb8468", "name": "l(r:p1rdt6507-p1rdt6539)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0db3e719-4dba-4b45-af70-c35546c19eb4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9707f264-8f82-4483-8337-6c89d709faf7"}}}], "length": {"value": 0.0349385, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "26afa7b6-b653-49b5-bf12-aa3c4938736f", "name": "l(r:p1rdt6507-p1rdt6530)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40ec7437-80f0-49e8-806a-c696b1402713"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0db3e719-4dba-4b45-af70-c35546c19eb4"}}}], "length": {"value": 0.28028700000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "221d6d6b-ad9e-406a-bf03-4b61c0d4feff", "name": "l(r:p1rdt6517-p1rdt6530)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b56340a0-81f0-4028-9283-532f0d92a412"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40ec7437-80f0-49e8-806a-c696b1402713"}}}], "length": {"value": 0.110659, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f60c7b67-fc17-4837-8efd-81efa3b23616", "name": "l(r:p1rdt6517-p1rdt6523)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "608945f2-9b19-43bc-83d9-0fe8787b06b4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b56340a0-81f0-4028-9283-532f0d92a412"}}}], "length": {"value": 0.281764, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "2c421fa7-4dd6-491c-998e-efe7bdb6b9f8", "name": "l(r:p1rdt6520-p1rdt6523)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24028ccd-3fd3-4461-b83c-54266f91a385"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b540c710-395d-4a35-8dc3-59d37609df09"}}}], "length": {"value": 0.0397382, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "ed24a3ca-3bd7-4de6-a546-05dc166ef9c8", "name": "l(r:p1rdt6501-p1rdt6520)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99fa55d1-867c-4db0-8697-b532da10d6d4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24028ccd-3fd3-4461-b83c-54266f91a385"}}}], "length": {"value": 0.0288844, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "be507d1a-0e3c-4956-b874-c26265167d1f", "name": "l(r:p1rdt6499-p1rdt6501)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "89434ebc-1e79-4414-9925-1a14f8e72fd6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99fa55d1-867c-4db0-8697-b532da10d6d4"}}}], "length": {"value": 0.0288269, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "6a77ab95-cadc-4be1-a0fe-1c155f22727c", "name": "l(r:p1rdt6499-p1rdt6509)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67c889f-e940-4242-9c83-4b5ab673d8a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "89434ebc-1e79-4414-9925-1a14f8e72fd6"}}}], "length": {"value": 0.026420600000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "b4fb2c7c-087c-479f-bb54-c153ff040105", "name": "l(r:p1rdt6508-p1rdt6509)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e165d0d-3f13-4d87-9c4b-fdfa8829f1f3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67c889f-e940-4242-9c83-4b5ab673d8a8"}}}], "length": {"value": 0.0278115, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "aac50a47-c224-459e-8507-4369a4d11f3a", "name": "l(r:p1rdt6508-p1rdt6521)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "302d2adf-2199-47b2-9f3c-e428bb409b6f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e165d0d-3f13-4d87-9c4b-fdfa8829f1f3"}}}], "length": {"value": 0.0189224, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f8244459-83a4-4ad3-a604-ec873ed20732", "name": "l(r:p1rdt6512-p1rdt6521)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f7572ed-6443-4e6e-8fb8-0b060b9f17ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "302d2adf-2199-47b2-9f3c-e428bb409b6f"}}}], "length": {"value": 0.0189224, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d5d29e6c-2471-43f5-85e9-7d24f91a352f", "name": "l(r:p1rdt6512-p1rdt6524)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ef8c502-c06f-43e5-90e6-23bd0ebcf155"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f7572ed-6443-4e6e-8fb8-0b060b9f17ce"}}}], "length": {"value": 0.0367319, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "672c8944-7a16-40e8-bdda-3b03fca4fecb", "name": "l(r:p1rdt7091-p1rdt7625)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6372a592-5e2d-41c8-819b-f56bfbb58e19"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2324afa4-5274-4392-9a0e-be8dc2bebeba"}}}], "length": {"value": 0.08221500000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f5dbe138-bea6-41cd-b524-27b90637c6e1", "name": "l(r:p1rdt7091-p1rdt7625)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2324afa4-5274-4392-9a0e-be8dc2bebeba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3e6cbe9-d1d3-4c59-981f-dad980f0999b"}}}], "length": {"value": 0.022555100000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f8e4f44c-08eb-469a-80c1-4f48efd02207", "name": "l(r:p1rdt7091-p1rdt7314)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0cf1844f-a32e-40f2-bc96-05fad3bdd88d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6372a592-5e2d-41c8-819b-f56bfbb58e19"}}}], "length": {"value": 0.55397, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "257675fc-6733-4332-ac51-3675463a4f35", "name": "l(r:p1rdt7314-p1rdt7318)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e86bc267-1607-4aa3-916f-ed826b0adfdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0cf1844f-a32e-40f2-bc96-05fad3bdd88d"}}}], "length": {"value": 0.048033200000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "e1ad2ae6-ae2b-46ab-a690-ea8d77ccc596", "name": "l(r:p1rdt7307-p1rdt7318)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "231b5cf9-ec2c-47d1-aada-5454926561dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e86bc267-1607-4aa3-916f-ed826b0adfdc"}}}], "length": {"value": 0.608118, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "12afdbdb-d635-4f2e-935d-dd9e846d84de", "name": "l(r:p1rdt6531-p1rdt7307)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8431ef4c-78dd-4a39-b15a-95818cfe1d86"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "231b5cf9-ec2c-47d1-aada-5454926561dd"}}}], "length": {"value": 0.626542, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "b628bac6-cc49-4fd0-869c-1e62b4f793f3", "name": "l(r:p1rdt6527-p1rdt6531)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "483b2d65-b496-4c6f-b01d-66aa3d9d4334"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "385eabe4-8c8e-4354-96ec-931e6c25574d"}}}], "length": {"value": 0.0295001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "00137112-a43a-4501-803e-980b8f2c0003", "name": "l(r:p1rdt6516-p1rdt6527)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5bd908fd-8bb8-42c1-8d1b-27c4e2574450"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "483b2d65-b496-4c6f-b01d-66aa3d9d4334"}}}], "length": {"value": 0.010689800000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "94115f94-82fa-4272-8a62-027168f25e3c", "name": "l(r:p1rdt6516-p1rdt6524)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ef8c502-c06f-43e5-90e6-23bd0ebcf155"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6191a237-532b-44e2-86a8-d9ed56b914b5"}}}], "length": {"value": 0.186537, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "5191d34f-932a-42dc-a5d6-0c1c0862b244", "name": "l(r:p1rdt6516-p1rdt6524)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6191a237-532b-44e2-86a8-d9ed56b914b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5bd908fd-8bb8-42c1-8d1b-27c4e2574450"}}}], "length": {"value": 0.014510300000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "310cb070-188c-4ff2-b290-6e36abcf555d", "name": "l(r:p1rdt6500-p1rdt6524)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a3d9ed9-e2e4-4332-89a2-358441869830"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97b7ef3c-ef16-4c4d-8559-722c5c67749a"}}}], "length": {"value": 0.0745596, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "beccb173-6f7b-4721-b3fb-e81b2efdd09f", "name": "l(r:p1rdt6500-p1rdt6515)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "18b822d0-cbe4-48d7-a818-87e25412d241"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0043b26d-8a33-4e32-a963-c4638f943775"}}}], "length": {"value": 0.030964300000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "de841033-13d8-4afb-bc0f-c55d72e49c5f", "name": "l(r:p1rdt6515-p1rdt6528)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04c3a970-215a-4e16-a798-80496ffad438"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8dcd059f-292b-4f7a-96c1-a3dc185f1eec"}}}], "length": {"value": 0.00777706, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "b9b34d6f-9985-4065-9d2f-788d5fa538da", "name": "l(r:p1rdt6528-p1rdt8898)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "918984ec-3b5f-4174-9bca-771bb10e0f60"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0156ae64-03dc-4ec0-89c8-8b09a6fc9090"}}}], "length": {"value": 0.0437869, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "75f64198-30d0-4129-ae28-939b6b4de497", "name": "l(r:p1rdt6532-p1rdt8898)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b51e96e7-2d7f-42af-9115-c9b1cfb3131c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "af1707bf-0b2e-4f76-96e7-c01338300d45"}}}], "length": {"value": 0.019358300000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "f1c45b69-986f-4c1d-aeaa-730d016e991d", "name": "l(r:p1rdt6532-p1rdt8902)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4a0469e-1a4a-466d-b18d-f3017b6415ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f373554-9d8a-4a9c-b418-25e67fbb43a9"}}}], "length": {"value": 0.0333077, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "88bad2e7-4dc4-4e4e-8175-a2a884f68169", "name": "l(r:p1rdt6052-p1rdt8902)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68b101ef-d71a-44d2-b1c2-4fc5e9f62499"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "468b1ce8-18fa-423b-99ca-1f3784437721"}}}], "length": {"value": 0.238793, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "eb115d37-81ae-4650-84a2-ae2f15289db2", "name": "l(r:p1rdt6046-p1rdt6052)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99e2ec8b-60fc-4a79-9eed-0d617babcb1d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49c69b43-f43b-4576-bbfa-d06b1d27de95"}}}], "length": {"value": 0.00843437, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "31a466b8-12d6-4b44-9bbb-89a8c774f869", "name": "l(r:p1rdt6043-p1rdt6046)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be3d7f84-84e7-46fc-a9ce-b3e0cf74d1d3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a147dd91-5597-40ff-93f9-0522ad3c726c"}}}], "length": {"value": 0.00839446, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "70cd133d-d616-4b6b-9e07-48fb34f306c9", "name": "l(r:p1rdt6043-p1rdt6045)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f01bba4-b8e8-45ed-af3b-1ac5a287ad46"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48d6768a-45e6-48a5-b22d-d5d418cb6221"}}}], "length": {"value": 0.04888200000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "f868b3e3-cc69-41ce-bcc7-0f7f802d7449", "name": "l(r:p1rdt6045-p1rdt6047)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34a9d21e-bcf7-4266-9834-60a72878ddd4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0396342e-2dc8-4a01-9da9-513953f9b5fa"}}}], "length": {"value": 0.08483280000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d8f16031-320a-40d2-a4bd-5b0e851ebb6c", "name": "l(r:p1rdt6038-p1rdt6047)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8898950-d712-40dc-99b5-33882b96b225"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34a9d21e-bcf7-4266-9834-60a72878ddd4"}}}], "length": {"value": 0.326021, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "598670a4-8ad9-464f-86c2-e9d706cc1558", "name": "l(r:p1rdt6038-p1rdt7599)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a086b782-3a8d-44e9-9948-cb7f051219e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cfe89e9-a7a8-456d-966b-67429017f456"}}}], "length": {"value": 0.186303, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "7223b7c0-3936-4480-8848-42bffaf1bdd0", "name": "l(r:p1rdt6038-p1rdt7599)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cfe89e9-a7a8-456d-966b-67429017f456"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8898950-d712-40dc-99b5-33882b96b225"}}}], "length": {"value": 2.13472, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "4d3942b3-144d-4b5b-82b8-ec7da5fb43f7", "name": "l(r:p1rdt6221-p1rdt7599)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0809ec5e-d36f-4bea-91b3-962ad6c29606"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a086b782-3a8d-44e9-9948-cb7f051219e3"}}}], "length": {"value": 0.192328, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d39bfedb-aa0c-466a-a29d-3c01eaa13638", "name": "l(r:p1rdt6208-p1rdt6221)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdfc617f-fbfb-4e9a-862e-cd5a296748cb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1a5a109-eee6-46be-be53-3fbe4a406575"}}}], "length": {"value": 0.728973, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "938225b2-6c7d-477d-9191-27d235904197", "name": "l(r:p1rdt6208-p1rdt6221)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1a5a109-eee6-46be-be53-3fbe4a406575"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0809ec5e-d36f-4bea-91b3-962ad6c29606"}}}], "length": {"value": 0.0421438, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "e39ddd12-2c19-406b-9cee-39fbbb7419bc", "name": "l(r:p1rdt6208-p1rdt8805)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "89f0c671-9d27-4dec-bd37-dc6c56f07e5d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdfc617f-fbfb-4e9a-862e-cd5a296748cb"}}}], "length": {"value": 0.531617, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "275d987b-6998-408d-8232-9db51e45c450", "name": "l(r:p1rdt5656-p1rdt5662)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17e89212-bc51-4fc2-83d1-4c74a285be23"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6f2bb66-d966-4228-8a13-96c57e8fbfba"}}}], "length": {"value": 0.240242, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "9904f6ea-b491-47e9-85aa-4261c1779673", "name": "l(r:p1rdt5656-p1rdt5662)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6f2bb66-d966-4228-8a13-96c57e8fbfba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f417a58d-5a47-4310-bac6-e8bb95fffc19"}}}], "length": {"value": 0.0265639, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "4573256d-e96e-413f-ac6b-b2c223599e79", "name": "l(r:p1rdt5183-p1rdt5662)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23f0bb81-3c30-45a5-89ca-2011e3881ddb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a05b2959-a8dd-417b-b566-8f84384a3559"}}}], "length": {"value": 0.290891, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "269826f4-1e62-47ca-aa90-96572f804c44", "name": "l(r:p1rdt5183-p1rdt5662)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a05b2959-a8dd-417b-b566-8f84384a3559"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17e89212-bc51-4fc2-83d1-4c74a285be23"}}}], "length": {"value": 1.81146, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "3f70e4f0-d581-4f32-bd85-f3b84da4c8ca", "name": "l(r:p1rdt4980-p1rdt5183)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35487e15-57cb-4e19-bef7-49074e5eb9ee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23f0bb81-3c30-45a5-89ca-2011e3881ddb"}}}], "length": {"value": 0.269563, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d3c03d49-abd6-4de6-8181-afe2d64d9e2a", "name": "l(r:p1rdt4980-p1rdt5017)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c09f718-9379-4281-86f6-55c46e46aec6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ddb0629-4947-47ca-83f9-9b7c073db235"}}}], "length": {"value": 0.216088, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "1c2a6e83-cb95-42de-bb6b-7b0e1cd4ea71", "name": "l(r:p1rdt4964-p1rdt5017)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7f13598-e628-457c-9ba6-d9a0123e882c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf1c765f-ca54-48cf-806f-6a1b5719c4b0"}}}], "length": {"value": 0.261316, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "eac4420e-03e8-40b1-ad16-db8f5eca18fc", "name": "l(r:p1rdt4964-p1rdt5017)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf1c765f-ca54-48cf-806f-6a1b5719c4b0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c09f718-9379-4281-86f6-55c46e46aec6"}}}], "length": {"value": 0.0641008, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "3b99e76c-8a82-4ca1-a9a0-80ecff2a4603", "name": "l(r:p1rdt4964-p1rdt8154)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42ab6054-1866-49c5-b2ab-3cf27199c1c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb1e0d86-907d-4564-a90e-c1400917d3ca"}}}], "length": {"value": 0.341502, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "55ed643d-0afa-4989-b1fd-d0adb37d81c8", "name": "l(r:p1rdt4964-p1rdt8154)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb1e0d86-907d-4564-a90e-c1400917d3ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7f13598-e628-457c-9ba6-d9a0123e882c"}}}], "length": {"value": 0.865306, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "5492331e-5c0a-4016-8ba0-bdc8e5d4f098", "name": "l(r:p1rdt8151-p1rdt8153)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b44d5021-4fdb-4618-bcb2-237ecf2e10e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40962258-28d3-4406-9e9e-121f373cce25"}}}], "length": {"value": 0.18735, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "05f00c42-916f-4b90-9aa8-833526068343", "name": "l(r:p1rdt8151-p1rdt8153)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40962258-28d3-4406-9e9e-121f373cce25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c794942-d5ce-481f-9c6a-563a2180a4ba"}}}], "length": {"value": 0.010421300000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d252c5f0-0b34-4738-8838-259761123b3c", "name": "l(r:p1rdt8153-p1rdt8154)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42ab6054-1866-49c5-b2ab-3cf27199c1c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b44d5021-4fdb-4618-bcb2-237ecf2e10e4"}}}], "length": {"value": 0.112826, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f7417ff2-16a5-4e81-a26b-dc86e9be6115", "name": "l(r:p1rdt8154-p1rdt9333)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0da91bf8-b687-47df-a7dc-41e6166fd667"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aef77ef-aaaa-4a6e-90ef-87348baaf1a0"}}}], "length": {"value": 0.37829, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "398b071f-89c3-461e-a564-1de7f6d5c967", "name": "l(r:p1rdt8154-p1rdt9333)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aef77ef-aaaa-4a6e-90ef-87348baaf1a0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42ab6054-1866-49c5-b2ab-3cf27199c1c8"}}}], "length": {"value": 0.2985030000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "76623ce2-1798-436d-8d11-cfcdc4e48d8e", "name": "l(r:p1rdt8805-p1rdt9333)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3444af6b-f9d4-4229-b6b2-2114300c3f94"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0da91bf8-b687-47df-a7dc-41e6166fd667"}}}], "length": {"value": 0.4807600000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "b055443b-30b0-4f4b-bbe3-54ed03e935bc", "name": "l(r:p1rdt8802-p1rdt8805)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26ccaeff-3a34-4835-8906-1145148549c6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3444af6b-f9d4-4229-b6b2-2114300c3f94"}}}], "length": {"value": 0.287236, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "62bc44cf-8afa-47da-9b7f-18b3ec7b3fff", "name": "l(r:p1rdt8802-p1rdt9413)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "401576cc-4ad6-42cd-bf1c-4022da720711"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e527bf48-b574-43bd-9a5d-484654dc76fe"}}}], "length": {"value": 1.38145, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "19fd814e-e169-4dc3-a33e-fae841593afd", "name": "l(r:p1rdt8802-p1rdt9413)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e527bf48-b574-43bd-9a5d-484654dc76fe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26ccaeff-3a34-4835-8906-1145148549c6"}}}], "length": {"value": 0.181709, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "06dd8bda-4d2d-43a7-a006-b168f73e922c", "name": "l(r:p1rdt5126-p1rdt9413)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0dafde2-c08e-4624-9212-e0fea9e47c2c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f750e531-5ade-40a9-9bb0-042220ce9807"}}}], "length": {"value": 1.23272, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "243ed967-e94e-485e-8b9d-afcbd257a23f", "name": "l(r:p1rdt5126-p1rdt5342)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c8f9ea6-06fb-4fd0-8629-ceea4f32189f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0dafde2-c08e-4624-9212-e0fea9e47c2c"}}}], "length": {"value": 1.97105, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "1a44ac5c-bd61-4c05-add0-330d7b09af79", "name": "l(r:p1rdt5476-p1rdt7624)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e240270-762d-49f0-a4e4-29fcd6273ce5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b077dc9c-1c6f-4403-ae0c-954e7cc0c692"}}}], "length": {"value": 0.421903, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "cc2acfa4-f76c-49fb-9790-7a02064a106b", "name": "l(r:p1rdt7624-p1rdt8159)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42b9c576-ddba-4be1-bc64-a37d8cbdfa84"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1ab9716-b9f3-44e5-b9f6-cd83d0904dd3"}}}], "length": {"value": 0.172459, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f0f84804-681f-45a5-b03b-c90ab2f2d6ff", "name": "l(r:p1rdt7624-p1rdt8159)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1ab9716-b9f3-44e5-b9f6-cd83d0904dd3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e240270-762d-49f0-a4e4-29fcd6273ce5"}}}], "length": {"value": 0.601263, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "542b2bb0-327d-4aab-a521-e1b0208513fc", "name": "l(r:p1rdt8159-p1rdt8161)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25946c74-15c2-412c-baed-8de5f7aecf98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42b9c576-ddba-4be1-bc64-a37d8cbdfa84"}}}], "length": {"value": 0.18407100000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "007f222e-ee77-4ddd-a2b9-453252e10c12", "name": "l(r:p1rdt7253-p1rdt8470)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f31b09da-e4cc-409e-9634-1907480039ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "442de065-9e2a-4ff8-9100-1298d3fe0f6f"}}}], "length": {"value": 1.51192, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f872437e-3f61-48ba-b719-7dec231c6092", "name": "l(r:p1rdt7248-p1rdt7253)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a006c5f-e960-4ae2-a37f-d23d7b873a22"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f31b09da-e4cc-409e-9634-1907480039ff"}}}], "length": {"value": 0.16946100000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "126d74f6-247e-4072-a5df-2c3d434063f3", "name": "l(r:p1rdt7220-p1rdt7248)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a2f1a631-48f7-4291-9adb-588a66620ebf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a006c5f-e960-4ae2-a37f-d23d7b873a22"}}}], "length": {"value": 0.306328, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "05aee401-6d4c-4709-8f97-3c50231daf5e", "name": "l(r:p1rdt7220-p1rdt8160)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38b72c12-2e2f-4d83-8f5a-9d8503dc29eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a2f1a631-48f7-4291-9adb-588a66620ebf"}}}], "length": {"value": 0.197573, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "95d74719-df14-429b-a976-0df68eb96622", "name": "l(r:p1rdt9075-p1rdt9084)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "907828f5-8e26-41c4-8fbc-a3744608181a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c10b6848-6c57-4243-8cb9-ec28d0a4c9dd"}}}], "length": {"value": 0.178898, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "3eafde29-da04-4c84-8fb6-7f4688eda991", "name": "l(r:p1rdt9075-p1rdt9084)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c10b6848-6c57-4243-8cb9-ec28d0a4c9dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4251587d-600f-40a0-9aec-229fb2e3f2df"}}}], "length": {"value": 0.27713400000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "fd3b2cfd-59b4-44c7-b0e7-303bae472d10", "name": "l(r:p1rdt9075-p1rdt9077)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b7f2f09-976a-45da-8186-229aeedeb689"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "907828f5-8e26-41c4-8fbc-a3744608181a"}}}], "length": {"value": 0.564064, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "347ee642-da70-4556-80d2-c3ac791c95eb", "name": "l(r:p1rdt9077-p1rdt9089)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b4ec275-bea8-45f2-94cb-5e24e82179d8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b7f2f09-976a-45da-8186-229aeedeb689"}}}], "length": {"value": 0.0696185, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f1cb1cc4-91cf-4ec1-a7a3-133827bae335", "name": "l(r:p1rdt9089-p1rdt9090)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52c72b52-1c6c-46f6-adbe-1054eb233c20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e4d2db3-67c5-4fef-996a-5774803c89b1"}}}], "length": {"value": 0.172405, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "fd0103af-8848-4f0a-8530-fac681f8ac46", "name": "l(r:p1rdt9089-p1rdt9090)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e4d2db3-67c5-4fef-996a-5774803c89b1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b4ec275-bea8-45f2-94cb-5e24e82179d8"}}}], "length": {"value": 0.0139334, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "df82aa08-b98c-4a21-89f9-d1b76cfe2af4", "name": "l(r:p1rdt9090-p1rdt9469)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3fd32c7-2866-4699-93a8-dd3a9997d349"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "708803a5-3daf-4892-96e3-b182e2d214ec"}}}], "length": {"value": 0.170175, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "fcb909f2-d354-474b-aee1-a6ca2eb94969", "name": "l(r:p1rdt9090-p1rdt9469)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "708803a5-3daf-4892-96e3-b182e2d214ec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52c72b52-1c6c-46f6-adbe-1054eb233c20"}}}], "length": {"value": 0.101162, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "2825eafe-8b85-450e-bed0-ab9a8e074f2d", "name": "l(r:p1rdt8160-p1rdt9469)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38b72c12-2e2f-4d83-8f5a-9d8503dc29eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3fd32c7-2866-4699-93a8-dd3a9997d349"}}}], "length": {"value": 0.245773, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "13deaf06-081a-4c2c-b09a-13b3d3c7335b", "name": "l(r:p1rdt8160-p1rdt8161)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8ecbd5b-6db5-44a0-b2a8-0233d4eb5b20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc9cbaf2-05bd-49aa-bd14-a363d4970d0f"}}}], "length": {"value": 0.191607, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "c5288543-a096-4660-bf4a-2929c4c54201", "name": "l(r:p1rdt8160-p1rdt8161)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc9cbaf2-05bd-49aa-bd14-a363d4970d0f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38b72c12-2e2f-4d83-8f5a-9d8503dc29eb"}}}], "length": {"value": 0.415051, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "b887aaee-21fc-4122-9966-afa362c2a743", "name": "l(r:p1rdt5236-p1rdt8161)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22db53ea-6d9a-4527-9b36-34a4bcd2c74f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67967bdd-155c-49fd-8d4c-29b40415a243"}}}], "length": {"value": 0.0839258, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f602002d-891a-4cda-82bc-55026a5de403", "name": "l(r:p1rdt5236-p1rdt8161)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67967bdd-155c-49fd-8d4c-29b40415a243"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25946c74-15c2-412c-baed-8de5f7aecf98"}}}], "length": {"value": 0.757497, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "10415944-6d9a-4497-bbb6-d304cebe9536", "name": "l(r:p1rdt5236-p1rdt5342)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9bbfae79-a578-4ff2-b622-3dddd9859ac8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22db53ea-6d9a-4527-9b36-34a4bcd2c74f"}}}], "length": {"value": 1.97703, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f8620c0f-f6b7-4b1c-abcf-c32e418abafc", "name": "l(r:p1rdt5342-p1rhs7_1247)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14208aa5-3197-4c90-adf9-3067dae9b5f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c8f9ea6-06fb-4fd0-8629-ceea4f32189f"}}}], "length": {"value": 0.373586, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "038d8c23-c731-48d4-9f20-56de4007395d", "name": "l(r:p1rdt5154lv-p1rlv10539)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9750085f-4afd-48ee-89f3-edbe9687b242"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08331744-08b7-455e-b2ca-284cae95fb06"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "4897e763-4729-42e4-a83c-2555a1a08472", "name": "l(r:p1rdt7632lv-p1rlv16271)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7235cf3a-dd26-47f7-884c-6335024a3064"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "606bf8f6-d745-4220-8cae-e01ffd22f669"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "323fd365-c57f-480b-9a0d-7f496d60a8db", "name": "l(r:p1rdt7632-p1rdt9265)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b336e76f-17f3-4f5d-ba84-f24c3a4e3eed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36e7cd28-6795-41d5-847d-92347871384f"}}}], "length": {"value": 0.178943, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "78cda3f2-1738-44fb-b107-a25d2930dde8", "name": "l(r:p1rdt5140-p1rdt9265)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b0fd055-d0ac-4678-a8e5-679e12741736"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60837f06-40cb-4f12-b36f-fe5e502c96d9"}}}], "length": {"value": 0.223266, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "455cb6d9-470c-4b2b-bfd7-589240e9226b", "name": "l(r:p1rdt5140-p1rdt9265)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60837f06-40cb-4f12-b36f-fe5e502c96d9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b336e76f-17f3-4f5d-ba84-f24c3a4e3eed"}}}], "length": {"value": 0.0122242, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "97bf6cd1-1211-4a45-8bf3-7091c7785df7", "name": "l(r:p1rdt6279lv-p1rlv13061)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6614f5e-517f-46cf-b049-09337d57228a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d46fd47-37f5-48a0-ba0d-d0746e6e6da3"}}}], "length": {"value": 0.0894278, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "a35032da-9a40-4dfe-ac94-e654ae966ae4", "name": "l(r:p1rdt6270-p1rdt6279)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb21415c-fc85-4197-82e5-545cb7be2ce9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1565cfb-f699-47db-9cbf-a76c32e3ea69"}}}], "length": {"value": 0.141369, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "f782b59f-9336-471b-a725-6924905057a8", "name": "l(r:p1rdt6270-p1rdt6279)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1565cfb-f699-47db-9cbf-a76c32e3ea69"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5c579309-9c05-4bae-ab97-2eca485e5ea7"}}}], "length": {"value": 0.0289817, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "e34d7eec-d2c0-4c8f-b361-a88dcd056e29", "name": "l(r:p1rdt6273lv-p1rlv13050)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07992f45-0c92-4a10-837d-4f58599d9b75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "051eba03-4728-4626-8add-5410b5326dc7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "f937594c-fb88-439e-99c9-fda1597eefef", "name": "l(r:p1rdt6268-p1rdt6273)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2f8b91d-339f-4151-90df-b0cad5c2f05a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d04f281-f394-432b-8b5c-cc1acb741369"}}}], "length": {"value": 0.0655674, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "6952320e-ff8d-460d-a4e6-eaf6036b287a", "name": "l(r:p1rdt6268-p1rdt6276)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b31c2adb-e4f4-4211-aac7-f317bf325d12"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce404489-b775-486b-9379-a30c801f6f94"}}}], "length": {"value": 0.246128, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "10f741eb-d2e6-4be0-af4e-b361024769a0", "name": "l(r:p1rdt6268-p1rdt6276)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce404489-b775-486b-9379-a30c801f6f94"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68d2e030-852f-44f6-9e02-d5587a1fc6a0"}}}], "length": {"value": 0.05302, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "84492e74-9344-46cb-a390-f1e004543e53", "name": "l(r:p1rdt6276-p1rdt6278)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51eefb94-724e-4dfe-9823-0f6cf8f56101"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "315af04d-a032-43a8-a2da-b9e68fd21f39"}}}], "length": {"value": 0.154279, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "62a19b90-201e-4b90-8182-f185a38720e2", "name": "l(r:p1rdt6277-p1rdt6278)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1dd4f893-7921-41c3-9e9e-d33e3680a999"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51eefb94-724e-4dfe-9823-0f6cf8f56101"}}}], "length": {"value": 0.0625926, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "b95ba635-9420-4efc-b1f4-f18ab2981eb2", "name": "l(r:p1rdt6269-p1rdt6277)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5ef97a6-6c60-46eb-acce-6469b273658a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "699595d6-8e08-41b1-8c3a-2aef170bb5f7"}}}], "length": {"value": 0.114982, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "6a531a0c-c604-445f-ad7e-c5819157e2fe", "name": "l(r:p1rdt6269-p1rdt6277)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "699595d6-8e08-41b1-8c3a-2aef170bb5f7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1dd4f893-7921-41c3-9e9e-d33e3680a999"}}}], "length": {"value": 0.0390023, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "fe16e73d-9f26-4912-b410-968f808d698e", "name": "l(r:p1rdt6045lv-p1rlv12555)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70bad714-71c1-4341-ac40-76312417dd03"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc71e486-4a44-466d-bc57-85591b269949"}}}], "length": {"value": 0.0236063, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "5d709edf-06ff-4ca8-9765-3865bab61031", "name": "l(r:p1rdt6052lv-p1rlv12567)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d830a1b-6971-4f4d-99bd-945e0785b5aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29476f95-f85b-4843-a847-3d9d99da3b74"}}}], "length": {"value": 0.0045077400000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "9c40129e-b9c4-4aff-b928-c2e84025b91f", "name": "l(r:p1rdt8902lv-p1rlv19164)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d1c8eb9-7f79-49ad-9e93-6c7cdcc95e22"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a02024b5-aa74-4e07-b043-a7a0e8b3e816"}}}], "length": {"value": 0.034742, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "90dd54ce-1778-49cf-a73f-6ed95b6c2526", "name": "l(r:p1rdt6537lv-p1rlv13720)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3f191ff-f8f2-4f13-af83-e67d1fdd366a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fe1a5da7-bdac-46a6-ab32-addc4f02a296"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "94cd3a09-1d25-466d-9330-f377442a7752", "name": "l(r:p1rdt6530-p1rdt6537)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40ec7437-80f0-49e8-806a-c696b1402713"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "45aca6e5-a8ee-4f45-80f3-e227379d33af"}}}], "length": {"value": 0.308478, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "55ed7480-a266-49da-beec-8b1b0d034468", "name": "l(r:p1rdt6530-p1rdt6537)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "45aca6e5-a8ee-4f45-80f3-e227379d33af"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "902291fa-9561-4f40-a4b7-4fd9fdded417"}}}], "length": {"value": 0.00557178, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "6f8d316a-82f6-4fc7-a734-a3c41faef455", "name": "l(r:p1rdt7313lv-p1rlv15628)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41e61263-feb6-4264-965a-fd1309d997a1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13eabcb1-332a-4c7a-8042-214ada721424"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "48ae8b06-1601-4570-9baa-08a0edd126d2", "name": "l(r:p1rdt7313-p1rdt7318)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e86bc267-1607-4aa3-916f-ed826b0adfdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a3a5e1c-77a2-4a9d-89e0-7d1c94176787"}}}], "length": {"value": 0.478103, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "e93ae957-665d-4d98-9565-61d7fa171d07", "name": "l(r:p1rdt7091lv-p1rlv15196)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0c42b48-7ca4-465f-b17c-048cb5f6d79b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64634ab5-a5b0-45ae-9763-7d0be029350f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "ced3202e-8eab-47a4-a979-fe58903c95a5", "name": "l(r:p1rdt5658lv-p1rlv11679)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f718935b-704d-4374-9172-856511e1eddd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4747e0f3-2a66-4e5a-8160-ac0aabe34489"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "e989189e-1d7f-413f-9447-be9c62919ce6", "name": "l(r:p1rdt5656-p1rdt5658)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f417a58d-5a47-4310-bac6-e8bb95fffc19"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81d6db26-881f-4cae-9514-df4c1e71c76e"}}}], "length": {"value": 0.6035390000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "5ba12d68-d1c2-4a66-b496-c299b151bf39", "name": "l(r:p1rdt5236-p1rdt8138)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0bab7e6b-74a6-4fe4-95e1-4ef96084f730"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22db53ea-6d9a-4527-9b36-34a4bcd2c74f"}}}], "length": {"value": 1.28532, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "3bc006be-04ae-45f9-8629-fd4cc42dcf20"}}}}, {"uuid": "76ff5ca6-d44b-4b4d-b1b5-c14739844a79", "name": "padswitch(r:p1rdt6270-p1rdt6271)p1r_14586", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "658514b3-59fd-44b7-95d6-a34cafcb47c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28954596-f060-4fa8-9f13-dfaa633bb739"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "47f16deb-bd0f-40f8-bed6-ee102cf95311", "name": "padswitch(r:p1rdt6270-p1rdt6271)p1r_14587", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b81bd5c2-96bb-445e-9eb8-d72360fd8a94"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a75c5e2-2277-42b4-87d4-6eadff5c06f1"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "fdb44f5f-12df-415f-a658-fc222a86212f", "name": "padswitch(r:p1rdt6500-p1rdt6519)p1r_14592", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9938a5c-b1cd-4592-814d-324ff2eb6644"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf648a0d-3262-4150-892b-55c3b117050a"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "6ba5defb-3101-4ef8-8d06-36719f7dad94"}}}}, {"uuid": "c2901c9f-984c-4dce-b45c-7e5ed1da1ce4", "name": "padswitch(r:p1rdt6500-p1rdt6519)p1r_14593", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5789c3b2-eb91-4e4c-85e8-24f5893e1a2c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "addd9f38-279f-4d9e-b216-38faef1940c7"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "fa89ef5e-f965-457f-a553-4831f61b03c7"}}}}, {"uuid": "111ecb31-3bbe-454e-8c3b-6d1f70eb1532", "name": "padswitch(r:p1rdt6515-p1rdt6535)p1r_14598", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acd6da90-895c-4d2c-80b4-1712b3949993"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fec078c2-a5d8-4317-a8ac-bc25772f6358"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "6ba5defb-3101-4ef8-8d06-36719f7dad94"}}}}, {"uuid": "bf3c2744-7527-4dae-99cf-5e2e7a4820ff", "name": "padswitch(r:p1rdt6515-p1rdt6535)p1r_14599", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5a05d0e-8cf2-4ab8-bdfd-24b8cd12ad67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b13053e-033e-4fe9-8eb3-89389e4bdc2b"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "fa89ef5e-f965-457f-a553-4831f61b03c7"}}}}, {"uuid": "2d52f48c-71fe-495c-a82d-13c4ed75d340", "name": "padswitch(r:p1rdt6515-p1rdt6536)p1r_14600", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0103161-4b16-4d25-a1f3-5a939317461f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04c1e05a-9cbb-4e53-9412-1cffd3976bed"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "6ba5defb-3101-4ef8-8d06-36719f7dad94"}}}}, {"uuid": "434eb627-cf53-4216-afff-7c43ac807514", "name": "padswitch(r:p1rdt6515-p1rdt6536)p1r_14601", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5aa6899b-19a2-41e6-b445-f9fe2536c8d9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f5cda74-5e33-4c52-8b2c-76bcd5e6c5cb"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "cbd826fb-5ba3-44b3-9c68-e5792dbd9854"}}}}, {"uuid": "28532c28-7be9-4805-8948-6769b876196e", "name": "padswitch(r:p1rdt6500-p1rdt6524)p1r_14594", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78b3b940-c277-441f-b2b3-83525ed85fcb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a3d9ed9-e2e4-4332-89a2-358441869830"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "d1d26e33-dcd5-4938-ad3f-174e4840c4f5", "name": "padswitch(r:p1rdt6500-p1rdt6524)p1r_14595", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97b7ef3c-ef16-4c4d-8559-722c5c67749a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ef8c502-c06f-43e5-90e6-23bd0ebcf155"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "c63cae3a-2224-4eff-aedd-06790f5bf45d", "name": "padswitch(r:p1rdt6500-p1rdt6515)p1r_14596", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1537ab1-dc7c-4bbd-b347-fc740d54fcf7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "18b822d0-cbe4-48d7-a818-87e25412d241"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "fc796329-2b2a-43b9-80c9-88427ef9b994"}}}}, {"uuid": "b26dbf8c-790a-40b5-ba1c-19b30138e3af", "name": "padswitch(r:p1rdt6500-p1rdt6515)p1r_14597", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0043b26d-8a33-4e32-a963-c4638f943775"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78b3b940-c277-441f-b2b3-83525ed85fcb"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "5f815f51-16da-46fa-b9b7-0a247327f57d", "name": "padswitch(r:p1rdt6515-p1rdt6528)p1r_14602", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ef5115d-ad7b-4671-b984-b9fd5969bf61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04c3a970-215a-4e16-a798-80496ffad438"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "a00c74d5-27a7-4365-a4b4-1caa240257e0", "name": "padswitch(r:p1rdt6515-p1rdt6528)p1r_14603", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8dcd059f-292b-4f7a-96c1-a3dc185f1eec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1537ab1-dc7c-4bbd-b347-fc740d54fcf7"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "fc796329-2b2a-43b9-80c9-88427ef9b994"}}}}, {"uuid": "f1f9def4-cddd-4b19-917f-09d63a013c98", "name": "padswitch(r:p1rdt6528-p1rdt8898)p1r_14604", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d887dbc-43bd-413e-8e72-5c95a2ed0be8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "918984ec-3b5f-4174-9bca-771bb10e0f60"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "1faec6b1-7f5b-4dcb-a048-3049e55d8b38", "name": "padswitch(r:p1rdt6528-p1rdt8898)p1r_14605", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0156ae64-03dc-4ec0-89c8-8b09a6fc9090"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ef5115d-ad7b-4671-b984-b9fd5969bf61"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "8e18082d-6d53-447e-b376-04046779e92e", "name": "padswitch(r:p1rdt6532-p1rdt8898)p1r_14606", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9f12ed7-454c-4cc9-a631-377121a07ba5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b51e96e7-2d7f-42af-9115-c9b1cfb3131c"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "2c2bcd91-cbfd-4595-aaff-70019c10c6fa", "name": "padswitch(r:p1rdt6532-p1rdt8898)p1r_14607", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "af1707bf-0b2e-4f76-96e7-c01338300d45"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d887dbc-43bd-413e-8e72-5c95a2ed0be8"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "c28bad83-c114-4053-9c9b-30bbedcabe0b", "name": "padswitch(r:p1rdt6532-p1rdt8902)p1r_14608", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f44ec9b-338a-4ae1-a26b-26422f218c13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4a0469e-1a4a-466d-b18d-f3017b6415ae"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "d6d0f63a-de65-45e9-bdee-6c551b470065", "name": "padswitch(r:p1rdt6532-p1rdt8902)p1r_14609", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f373554-9d8a-4a9c-b418-25e67fbb43a9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9f12ed7-454c-4cc9-a631-377121a07ba5"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "afa67d84-29d7-4458-849e-84ed0e1b595b", "name": "padswitch(r:p1rdt6052-p1rdt8902)p1r_14610", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c10f182d-aa76-4633-9a84-f41e20b97da1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68b101ef-d71a-44d2-b1c2-4fc5e9f62499"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "fa28c17c-346e-462b-82a7-05a8c4f9581e", "name": "padswitch(r:p1rdt6052-p1rdt8902)p1r_14611", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "468b1ce8-18fa-423b-99ca-1f3784437721"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f44ec9b-338a-4ae1-a26b-26422f218c13"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "b7883a9b-3e71-4054-8da3-871e4aca2b0d", "name": "padswitch(r:p1rdt6046-p1rdt6052)p1r_14612", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67bc3ce6-e23d-4899-b0e8-9783225338ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99e2ec8b-60fc-4a79-9eed-0d617babcb1d"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "6f1d6c03-5c03-49ba-8dab-68f7e30ab2cb", "name": "padswitch(r:p1rdt6046-p1rdt6052)p1r_14613", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49c69b43-f43b-4576-bbfa-d06b1d27de95"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c10f182d-aa76-4633-9a84-f41e20b97da1"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "6639a595-3f1b-44a9-86be-51fa881ce680", "name": "padswitch(r:p1rdt6043-p1rdt6046)p1r_14614", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "87e05b2f-c346-452c-9c72-a6db090c3124"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be3d7f84-84e7-46fc-a9ce-b3e0cf74d1d3"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "91227638-fd33-4479-9525-2d57047db981", "name": "padswitch(r:p1rdt6043-p1rdt6046)p1r_14615", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a147dd91-5597-40ff-93f9-0522ad3c726c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67bc3ce6-e23d-4899-b0e8-9783225338ff"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "689b9014-1cdc-4acc-8b3e-df03f6b21e70", "name": "padswitch(r:p1rdt6043-p1rdt6045)p1r_14616", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0396342e-2dc8-4a01-9da9-513953f9b5fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f01bba4-b8e8-45ed-af3b-1ac5a287ad46"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4900e609-ebb1-44db-852b-602449095f15"}}}}, {"uuid": "03180cf9-2727-4493-8873-aff288e916b6", "name": "padswitch(r:p1rdt6043-p1rdt6045)p1r_14617", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48d6768a-45e6-48a5-b22d-d5d418cb6221"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "87e05b2f-c346-452c-9c72-a6db090c3124"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "6d8a26df-5a49-4e47-869d-4d8122f519ba", "name": "padswitch(r:p1rdt6270-p1rdt6279)p1r_14588", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cf36152-b3af-49f7-b693-5d465db1f283"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb21415c-fc85-4197-82e5-545cb7be2ce9"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "7f30a525-3333-4b58-92ea-577806eca7df", "name": "padswitch(r:p1rdt6270-p1rdt6279)p1r_14589", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5c579309-9c05-4bae-ab97-2eca485e5ea7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "632d8db5-5220-4188-94f0-f6131253820b"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "636897ae-1c34-4ac7-a975-9d28d5b5e703", "name": "padswitch(r:p1rdt6268-p1rdt6276)p1r_14590", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "315af04d-a032-43a8-a2da-b9e68fd21f39"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b31c2adb-e4f4-4211-aac7-f317bf325d12"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "e469ce7f-3983-4e1e-8e32-aa82775148e2", "name": "padswitch(r:p1rdt6268-p1rdt6276)p1r_14591", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68d2e030-852f-44f6-9e02-d5587a1fc6a0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2f8b91d-339f-4151-90df-b0cad5c2f05a"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "7a4d0af0-a80d-4a34-9690-847471cef160", "name": "fuse(r:p1rdt5017-p1rdt5200)p1r_17536", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c09f718-9379-4281-86f6-55c46e46aec6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0843e99-e917-473c-bec7-ee0c3ddec601"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "2c1ba8d6-9c7d-4bff-8436-d9ee96d6015c", "name": "fuse(r:p1rdt5180-p1rdt5201)p1r_17572", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6316fa2-dd57-46d4-89c0-f11dd675d686"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86d3f96e-ffe2-459f-a2f1-b63d7bf138b8"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "b5dcf106-1044-4f87-a7f6-75974485309d", "name": "fuse(r:p1rdt5180-p1rdt7988)p1r_17573", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6316fa2-dd57-46d4-89c0-f11dd675d686"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "893d2436-cd6c-40ad-90af-64ba1ac23f6e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "82ed7871-cb02-4db6-91d5-ce60e7d4e1e2", "name": "fuse(r:p1rdt5472-p1rdt5476)p1r_17641", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b077dc9c-1c6f-4403-ae0c-954e7cc0c692"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d69527e6-70b6-43e2-8b9e-7c8570ad5ddf"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770"}}}}, {"uuid": "82617c5e-c2cc-455d-8527-5601ea90767d", "name": "fuse(r:p1rdt5475-p1rdt5476)p1r_17642", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b077dc9c-1c6f-4403-ae0c-954e7cc0c692"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae343ca3-3337-4528-b117-38a51e6d023f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770"}}}}, {"uuid": "ccf9e034-77fc-426b-b591-d140fef045d2", "name": "fuse(r:p1rdt5476-p1rdt5478)p1r_17643", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b077dc9c-1c6f-4403-ae0c-954e7cc0c692"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c977e6c-43f0-4d7e-b19f-82f0de97dab2"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "a4cfd253-7e2b-44c8-ad94-7e49d479f7d6", "name": "fuse(r:p1rdt5658-p1rdt5663)p1r_17692", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81d6db26-881f-4cae-9514-df4c1e71c76e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81f0e00e-bc49-448a-8e69-0569ed6a8c1a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "d9f2eb29-6d43-4a3e-97a3-82df1571da0f", "name": "fuse(r:p1rdt5658-p1rdt7070)p1r_17693", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81d6db26-881f-4cae-9514-df4c1e71c76e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02407b52-58c3-403c-9b5b-38695f435476"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "9b63d6fe-307e-4ee6-b4a9-7f9f2da30a37", "name": "fuse(r:p1rdt5650-p1rdt5662)p1r_17694", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17e89212-bc51-4fc2-83d1-4c74a285be23"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36c3c493-ff68-4bb8-a3f4-043c5f847bd3"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "30827bea-a4e8-4efe-b4d7-efcfb1e9320b", "name": "fuse(r:p1rdt6270-p1rdt6271)p1r_17809", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cf36152-b3af-49f7-b693-5d465db1f283"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "658514b3-59fd-44b7-95d6-a34cafcb47c5"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "f0933dbe-d79b-4dc5-a90e-5baecda8695c", "name": "fuse(r:p1rdt5179-p1rdt6273)p1r_17810", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d04f281-f394-432b-8b5c-cc1acb741369"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9722136-480b-44cb-8b0e-0b3165712688"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "af71c4ff-4d6e-4ab4-9d66-7d164afa30e7", "name": "fuse(r:p1rdt6278-p1rdt8439)p1r_17811", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51eefb94-724e-4dfe-9823-0f6cf8f56101"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19d5304c-574f-4646-8095-d2dcbbea86e7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "29527017-032c-4b43-bd84-238ae4b0d637", "name": "fuse(r:p1rdt6500-p1rdt6519)p1r_17854", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78b3b940-c277-441f-b2b3-83525ed85fcb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9938a5c-b1cd-4592-814d-324ff2eb6644"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "861d64ae-aba6-4135-a3ca-f177438722a2"}}}}, {"uuid": "5ba4b830-feba-4c34-9f6a-d9a4acea95aa", "name": "fuse(r:p1rdt6501-p1rdt9468)p1r_17855", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99fa55d1-867c-4db0-8697-b532da10d6d4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddfa01c0-4d12-4f96-ab50-0082ef9914a6"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "d467c779-b0de-4d04-a83b-e77928c92e89", "name": "fuse(r:p1rdt6505-p1rdt6508)p1r_17856", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e165d0d-3f13-4d87-9c4b-fdfa8829f1f3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0824c21-244b-4d4e-85d6-238ac4908b5a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "e57e9e13-5001-4417-a3f6-ab5934b145e3", "name": "fuse(r:p1rdt6509-p1rdt6514)p1r_17857", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67c889f-e940-4242-9c83-4b5ab673d8a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42f09ae1-037a-4565-9cd2-0187c45b7866"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "dd4f8c56-9e34-4519-b5c5-cbf9f9aef255", "name": "fuse(r:p1rdt6515-p1rdt6535)p1r_17861", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1537ab1-dc7c-4bbd-b347-fc740d54fcf7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acd6da90-895c-4d2c-80b4-1712b3949993"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "ab93cbf0-52fd-4d3d-a7f9-fd7cb4376fa6"}}}}, {"uuid": "f40fc1ae-26eb-4491-bdbb-89a93f0a5ed4", "name": "fuse(r:p1rdt6515-p1rdt6536)p1r_17862", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1537ab1-dc7c-4bbd-b347-fc740d54fcf7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0103161-4b16-4d25-a1f3-5a939317461f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "ab93cbf0-52fd-4d3d-a7f9-fd7cb4376fa6"}}}}, {"uuid": "2aa6f2b8-2a32-42fc-90f2-fa7a8c55098c", "name": "fuse(r:p1rdt6498-p1rdt6516)p1r_17863", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5bd908fd-8bb8-42c1-8d1b-27c4e2574450"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60b93cd6-c9fc-46ef-8b37-6b14d0773df6"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "29b3f03f-9571-4cf7-9677-dfd361d7772d", "name": "fuse(r:p1rdt6518-p1rdt9311)p1r_17864", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d39c608-5688-4e22-8ac4-96b896265274"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95d939ff-e20d-42b3-bb88-f1975f9fa0aa"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770"}}}}, {"uuid": "1b5e8967-c098-465d-af7c-c04a15173c41", "name": "fuse(r:p1rdt6510-p1rdt6523)p1r_17865", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b540c710-395d-4a35-8dc3-59d37609df09"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66b7b2e9-7658-4de0-8197-3829c6179353"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "3dfebf9a-38af-4642-a33a-d6e2ded3d3d3", "name": "fuse(r:p1rdt5728-p1rdt6537)p1r_17866", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "902291fa-9561-4f40-a4b7-4fd9fdded417"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66ef2ffb-e67d-47eb-ae59-194c538ab861"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "99c97fbd-6df7-451e-8cda-f3cbb38af5c8", "name": "fuse(r:p1rdt7036-p1rdt7091)p1r_17967", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6372a592-5e2d-41c8-819b-f56bfbb58e19"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28d17238-8db8-41da-960c-317183423576"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "43c81b03-5700-4da4-8f70-67963aaef0ac", "name": "fuse(r:p1rdt7298-p1rdt7313)p1r_17994", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a3a5e1c-77a2-4a9d-89e0-7d1c94176787"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1f6ad7d-f7ea-4b94-956c-ec4a3b2028d5"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "5536ecf7-d8e7-4008-b350-e418d4c32378", "name": "fuse(r:p1rdt7554-p1rdt7570)p1r_18045", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9b94106-b7c5-4ce9-9c19-053487848c2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2bdb2b51-0526-4995-bb5e-a2bd495488d4"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "6013789b-d1a7-4068-b10a-f2499431a3e3", "name": "fuse(r:p1rdt7559-p1rdt7570)p1r_18046", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9b94106-b7c5-4ce9-9c19-053487848c2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09814176-7891-4fe1-addf-b47aa106c40d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "8c46219e-0ca9-4c62-b0d1-27774f373511", "name": "fuse(r:p1rdt7551-p1rdt7574)p1r_18047", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd487832-bc77-406f-a995-4b099fad7c64"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1d8c14d0-8247-4a44-98c1-4534aa9037a2"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770"}}}}, {"uuid": "15bcd57b-3325-4415-8d0c-e10363a4d084", "name": "fuse(r:p1rdt7553-p1rdt7574)p1r_18048", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd487832-bc77-406f-a995-4b099fad7c64"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f00dd033-8e7c-43af-bd16-1de2954e07be"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "cbed5d9f-5e20-4900-b098-41ced4f2e4c7", "name": "fuse(r:p1rdt7599-p1rdt8492)p1r_18054", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a086b782-3a8d-44e9-9948-cb7f051219e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "605c34bc-3f7c-4eb7-8df0-fcd00d261921"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "87a1de9d-91b1-4052-ab8c-9c01790a77d8", "name": "fuse(r:p1rdt6847-p1rdt7624)p1r_18055", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e240270-762d-49f0-a4e4-29fcd6273ce5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be9350ab-7ad2-4a89-a374-94bf69588d7f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "a063cb46-3701-476f-b259-2890451a38db", "name": "fuse(r:p1rdt7617-p1rdt7625)p1r_18056", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3e6cbe9-d1d3-4c59-981f-dad980f0999b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a11cf3d9-90bb-4de8-b637-6ec9128525ec"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "fc77f72a-a5f7-465d-aa39-93591b6b0878", "name": "fuse(r:p1rdt7621-p1rdt7625)p1r_18057", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3e6cbe9-d1d3-4c59-981f-dad980f0999b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53df7b6e-bd8c-43f2-860d-8869aec5d079"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "d64e4be1-0395-4089-96bf-26178c53784e", "name": "fuse(r:p1rdt7625-p1rdt7631)p1r_18058", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3e6cbe9-d1d3-4c59-981f-dad980f0999b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "460f5de9-8d4f-468a-b67a-b3b05354a9ce"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "09949c3d-86ce-4fb6-a416-b2b63b50edc5", "name": "fuse(r:p1rdt7576-p1rdt8151)p1r_18146", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c794942-d5ce-481f-9c6a-563a2180a4ba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a31fa2-4df8-418a-a215-d0d450ced9a3"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "f0e0af75-4597-4f6c-930a-4e193179b902", "name": "fuse(r:p1rdt8151-p1rdt8155)p1r_18147", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c794942-d5ce-481f-9c6a-563a2180a4ba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0a6628e-afc1-4daf-8a29-7626ac2aa5dd"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "fb5f1e22-94af-4dc6-89b5-0b586358c8cb", "name": "fuse(r:p1rdt8405-p1rdt8445)p1r_18212", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60829dab-c129-4017-961a-81435d8afa93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8c69243-872f-4e25-9d03-82692bbf8779"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "70b85fee-d939-41de-9968-944ff2b25094", "name": "fuse(r:p1rdt8414-p1rdt8456)p1r_18215", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b48f78d-1092-4536-bfb3-029da6a70dff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34054ef8-8942-4471-ac14-43c6a37e5a16"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "85454510-f466-49d9-93d2-1381c0acd28a", "name": "fuse(r:p1rdt6347-p1rdt8470)p1r_18224", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "442de065-9e2a-4ff8-9100-1298d3fe0f6f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6163371c-55ef-4900-a3ef-2e4e8fc2894a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "d0487dc6-e327-4fb9-8124-bce8e04cfc95", "name": "fuse(r:p1rdt7268-p1rdt8470)p1r_18225", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "442de065-9e2a-4ff8-9100-1298d3fe0f6f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6225b33-2abc-4f77-9d65-459794f56353"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "4a4594e8-f914-4990-ba21-6c90a130e917", "name": "fuse(r:p1rdt8901-p1rdt8902)p1r_18292", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f44ec9b-338a-4ae1-a26b-26422f218c13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d21061fa-1011-44f7-8a20-26fcf0550f52"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "861d64ae-aba6-4135-a3ca-f177438722a2"}}}}, {"uuid": "c53f224c-161b-4771-a189-43944175e441", "name": "fuse(r:p1rdt8902-p1rdt9377)p1r_18293", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f44ec9b-338a-4ae1-a26b-26422f218c13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43c862de-b014-4b24-8b34-54dae6edcf5a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "861d64ae-aba6-4135-a3ca-f177438722a2"}}}}, {"uuid": "6f8f40b9-00fa-445b-a260-2f2b7058d7fb", "name": "fuse(r:p1rdt6581-p1rdt9084)p1r_18331", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4251587d-600f-40a0-9aec-229fb2e3f2df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6114624f-81c8-4d9c-8f9a-3ab73158596e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "198bb22e-539d-4ad2-99eb-c99330a282b0", "name": "fuse(r:p1rdt9076-p1rdt9084)p1r_18332", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4251587d-600f-40a0-9aec-229fb2e3f2df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12b4dc99-fe50-457c-90aa-48a2fb19ebf1"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "db412f85-aaee-44e6-b2f7-6c05006c4a3f", "name": "fuse(r:p1rdt7790-p1rdt9090)p1r_18334", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52c72b52-1c6c-46f6-adbe-1054eb233c20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15a7847f-aa96-4206-b4c6-422802f4e0a6"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "e8b8932b-1bea-473d-b138-d323af891be4", "name": "fuse(r:p1rdt9090-p1rdt9091)p1r_18335", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52c72b52-1c6c-46f6-adbe-1054eb233c20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf719d10-8168-4d80-894e-1b1516f033e8"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "36b7e8e3-1a5f-4604-9ffe-b88b6a71ea45", "name": "fuse(r:p1rdt6226-p1rdt9333)p1r_18385", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0da91bf8-b687-47df-a7dc-41e6166fd667"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f6d3fab-3b83-40c9-85c4-cfeddd0d317a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "3bf77ce1-4f77-4f4c-902e-9b4293967914", "name": "fuse(r:p1rdt9469-p1rdt9470)p1r_18407", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3fd32c7-2866-4699-93a8-dd3a9997d349"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5f6a2ec-3ddd-4ba7-9c55-88b4d82e7735"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "7d4a8786-91d9-4845-8fe5-8e8f350b4a94", "name": "fuse(r:p1rdt5730-p1rdt9479)p1r_18410", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b006c3-79f8-4a27-b76a-d1b458ff2a21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e07d8bc1-2f8a-4067-a2a7-b903dd042ce3"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "8b1e7929-00be-4710-9892-83b9f936f05c", "name": "fuse(r:p1rdt5840-p1rdt9479)p1r_18411", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b006c3-79f8-4a27-b76a-d1b458ff2a21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7f9286b-4209-402a-a365-1d27da4efb75"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "2c304709-0eb6-47d1-aa82-ab4b517d007e", "name": "recloser_disswitch(r:p1rdt8802-p1rdt9413)p1r_20691", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f750e531-5ade-40a9-9bb0-042220ce9807"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "401576cc-4ad6-42cd-bf1c-4022da720711"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "140f67fe-0cf8-45a3-8e1d-7cd225dab6f1"}}}}, {"uuid": "84d72fc4-99d1-4474-99ef-ab56621f28e6", "name": "goab_disswitch(r:p1rdt5236-p1rdt5342)p1r_20760", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c8f9ea6-06fb-4fd0-8629-ceea4f32189f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9bbfae79-a578-4ff2-b622-3dddd9859ac8"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "1848ee60-41cc-4072-ae7a-8f2e890e75ff", "name": "goab_disswitch(r:p1rdt6531-p1rdt7307)p1r_20862", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "385eabe4-8c8e-4354-96ec-931e6c25574d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8431ef4c-78dd-4a39-b15a-95818cfe1d86"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "60e69ce7-f8f6-4852-ae1e-694ae07f37f5", "name": "recloser_disswitch(r:p1rdt8405-p1rdt9413)p1r_20975", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f750e531-5ade-40a9-9bb0-042220ce9807"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16ecb938-cd0c-4be5-a915-be0d84d351f2"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "140f67fe-0cf8-45a3-8e1d-7cd225dab6f1"}}}}, {"uuid": "bb69f156-d7c0-40a5-87e3-b6c622faea56", "name": "goab_disswitch(r:p1rdt6208-p1rdt8805)p1r_20999", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3444af6b-f9d4-4229-b6b2-2114300c3f94"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "89f0c671-9d27-4dec-bd37-dc6c56f07e5d"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "b7056dc9-d1ea-4fc2-a609-6d09d60d3fac", "name": "goab_disswitch(r:p1rdt6517-p1rdt6523)p1r_21014", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b540c710-395d-4a35-8dc3-59d37609df09"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "608945f2-9b19-43bc-83d9-0fe8787b06b4"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "c505d68e-64f2-48ac-afb2-f29694bbaa79", "name": "disswitch(r:p1rdt5195-p1rdt5202)p1r_21153", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97e4f179-9d60-4183-8326-eb0ab98a53eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "227d848c-cddc-4561-996b-f8f7a60a5a89"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "ee8a464c-5fc6-41d0-9c41-36add8ffa204", "name": "goab_disswitch(r:p1rdt8160-p1rdt8161)p1r_21295", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25946c74-15c2-412c-baed-8de5f7aecf98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8ecbd5b-6db5-44a0-b2a8-0233d4eb5b20"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "0799b34e-32a2-4275-b73b-5d5b98a2674b", "name": "goab_disswitch(r:p1rdt4980-p1rdt5183)p1r_21308", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ddb0629-4947-47ca-83f9-9b7c073db235"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35487e15-57cb-4e19-bef7-49074e5eb9ee"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "ca277d25-50a6-4bf9-becf-59896b3145c3", "name": "l(r:p1rdt6501-p1rdt9468)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e4fd2ed-daa1-4a22-936f-8d51ee928d99"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "edf27f1d-b486-434e-92be-963bdeb26090"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "40a26197-da2a-4e22-a50a-3922efd7762c"}}}}, {"uuid": "22c44cd1-4a06-4e8d-9f99-9f622360b34c", "name": "l(r:p1rdt6501-p1rdt9468)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "edf27f1d-b486-434e-92be-963bdeb26090"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b5695dd-714e-4de1-a63a-f142ff0460e1"}}}], "length": {"value": 0.907254, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e3949704-59de-4ac0-a856-a028f2766fb2", "name": "l(r:p1rdt8902-p1rdt9377)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32e86968-974e-4bcc-b562-1d4209771cf0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e62ba05d-920f-4f55-b1c6-3aa078e0073d"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "40a26197-da2a-4e22-a50a-3922efd7762c"}}}}, {"uuid": "f111d805-c7d0-4e6b-beee-74b482cec4f6", "name": "l(r:p1rdt8902-p1rdt9377)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e62ba05d-920f-4f55-b1c6-3aa078e0073d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61972a50-ce24-4ec1-8535-402665b55a55"}}}], "length": {"value": 1.557306, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3a055c24-acdd-4c3d-8cc6-653f0d8be826", "name": "l(r:p1rdt5195-p1rdt5653)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fbc486eb-4f08-4602-a101-1298d4a46b32"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ccc9dcb-3a72-4f11-9bcf-e3a7f1a21985"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "40a26197-da2a-4e22-a50a-3922efd7762c"}}}}, {"uuid": "313717c1-fa7c-4f6e-b27e-12c06e71e69e", "name": "l(r:p1rdt5195-p1rdt5653)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ccc9dcb-3a72-4f11-9bcf-e3a7f1a21985"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "769c14db-ac3f-438d-9f7d-c7eb2d3074b5"}}}], "length": {"value": 0.915894, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4399bb4b-ec3f-463a-b5d0-16570e8eb9b9", "name": "l(r:p1rdt28lv-p1rlv51)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b3c997d-cd47-439c-aeb9-326e12c2b869"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ccef6af-4bf6-44dc-b292-2bf9503a374a"}}}], "length": {"value": 0.0198886, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4aaad3fe-4de0-4afb-8264-3875d74a560e", "name": "l(r:p1rdt28lv-p1rlv53)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b3c997d-cd47-439c-aeb9-326e12c2b869"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3c62646-6132-41ef-ba14-a06789885cd5"}}}], "length": {"value": 0.0198886, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d32a111a-c62d-4052-bf39-48c43dab30fb", "name": "l(r:p1rdt29lv-p1rlv52)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61fc3980-6aa4-415c-91c1-10d32c7c359c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fec0a162-4b0c-4577-b878-8dbc7c9935fc"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "537e8b73-0d40-4f17-a28d-0aae6b098e14", "name": "l(r:p1rdt30lv-p1rlv62)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d2be3b5-dbfc-4099-af9a-96368e60fe23"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "346dad85-3bf8-41a6-97ea-6b3b40a7f22e"}}}], "length": {"value": 0.028845, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "85b7ab92-76f2-4b11-843c-08ecd9d88d3d", "name": "l(r:p1rdm56-p1rlv54)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c89ec162-cda3-4c40-8833-3fff085538ba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20010301-32ce-4cc0-ab59-04ef3bcd35d7"}}}], "length": {"value": 0.0170492, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ddaa35ee-6a95-4aea-8dd8-4c94f1fce2c3", "name": "l(r:p1rdm56-p1rdt30lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d2be3b5-dbfc-4099-af9a-96368e60fe23"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c89ec162-cda3-4c40-8833-3fff085538ba"}}}], "length": {"value": 0.0189193, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9b7fb251-9269-4d78-8c55-47059d037541", "name": "l(r:p1rdm58-p1rlv55)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59ff3c1b-38f4-4a33-86fa-e956951c0f2c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36bdbc4e-edfa-425a-8e4c-e6123b567555"}}}], "length": {"value": 0.013887, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "859a2d9c-f5ee-4913-8ea2-6fdfbcfab2b9", "name": "l(r:p1rdm60-p1rlv152)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f678ceb4-b717-44a5-9db9-f698bece6935"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25b891ce-797a-4a4d-b664-4225fba806c4"}}}], "length": {"value": 0.0140747, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "aa7cc74b-1797-4884-9885-e3500e2380d9", "name": "l(r:p1rdm58-p1rdm60)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59ff3c1b-38f4-4a33-86fa-e956951c0f2c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f678ceb4-b717-44a5-9db9-f698bece6935"}}}], "length": {"value": 0.0566856, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7fb3cf19-7676-4fc4-ab81-0e769d75d414", "name": "l(r:p1rdm58-p1rdt31lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3510eedd-535c-4e58-b81e-c5ec09030479"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59ff3c1b-38f4-4a33-86fa-e956951c0f2c"}}}], "length": {"value": 0.0140094, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d9c6db05-7bc3-4ad3-84d9-f60e07fa7a5f", "name": "l(r:p1rdm59-p1rlv58)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a0a4841-bf31-4498-98d9-115cc159981c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a32ee184-f677-4333-b7ee-7bc30ab41467"}}}], "length": {"value": 0.0220532, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "19418b76-199d-4da4-a457-d31bd2cc8bd2", "name": "l(r:p1rdm59-p1rdt31lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3510eedd-535c-4e58-b81e-c5ec09030479"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a0a4841-bf31-4498-98d9-115cc159981c"}}}], "length": {"value": 0.0494128, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8b247c95-6202-4fe5-940d-4492e1bffb6c", "name": "l(r:p1rdt32lv-p1rlv414)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e374d6d6-1e75-4808-b65a-c7033e1bd528"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec2c1edd-78b1-4436-85cc-2fbc7d880b87"}}}], "length": {"value": 0.00981453, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f0dff6bc-98c3-4316-b25d-c48ba2181493", "name": "l(r:p1rdm61-p1rlv56)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cef7aa37-7ca0-4130-9bcd-1804a811245a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4694811a-ba43-4c78-b957-5209b1d961e2"}}}], "length": {"value": 0.0329346, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3bbc54a5-ff57-420e-b9f4-554e9a130e80", "name": "l(r:p1rdm61-p1rdt32lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e374d6d6-1e75-4808-b65a-c7033e1bd528"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cef7aa37-7ca0-4130-9bcd-1804a811245a"}}}], "length": {"value": 0.0318291, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6fc81b07-6ca8-4ea4-8296-3a5318abe131", "name": "l(r:p1rdt33lv-p1rlv170)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "065c8583-45e5-466c-b4c0-1c66bf970abe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f7dbd18-1cbe-49d3-b490-3c46cf8e37f1"}}}], "length": {"value": 0.0380059, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "16b7dcf9-eccc-4d50-bf94-8699ecae0e2f", "name": "l(r:p1rdm63-p1rlv57)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0538c66-18d7-440e-9efd-6b2945d50f2b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "925cb3b7-4ced-4a36-913f-e6851ed79b98"}}}], "length": {"value": 0.030867800000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2bdd73c1-d6c6-46df-925e-e5b975ebcf7e", "name": "l(r:p1rdm63-p1rdt33lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "065c8583-45e5-466c-b4c0-1c66bf970abe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0538c66-18d7-440e-9efd-6b2945d50f2b"}}}], "length": {"value": 0.0345517, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "83b76af1-5305-4dbc-bb4d-1ae26fa9de1d", "name": "l(r:p1rdm64-p1rlv61)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfa2eaff-b163-46ce-b6e5-516680d39bc3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d22bf2f5-74cc-47c7-ae3b-410fba27c113"}}}], "length": {"value": 0.0241386, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3898954b-b312-40ab-ac32-628c8dce2ca0", "name": "l(r:p1rdm64-p1rdt33lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "065c8583-45e5-466c-b4c0-1c66bf970abe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfa2eaff-b163-46ce-b6e5-516680d39bc3"}}}], "length": {"value": 0.0177518, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "02917748-21d7-4d1d-ba3e-9a59a7f04498", "name": "l(r:p1rdm66-p1rlv59)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72ee0111-4849-4280-b3c9-c0627d1a6c09"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b80bdb24-4bbf-4a57-bd5f-6a5ec9d484dd"}}}], "length": {"value": 0.024402100000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a261116f-a80b-4209-9176-cbc942356177", "name": "l(r:p1rdm66-p1rdt34lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "553a6868-acec-4492-a52d-5aa08414c612"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72ee0111-4849-4280-b3c9-c0627d1a6c09"}}}], "length": {"value": 0.0174345, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "efad20b9-c489-41bc-9b18-f645e0471962", "name": "l(r:p1rdm67-p1rlv67)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "713c1538-ceb4-46df-a996-6c591c0f8e40"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64a67ed2-a563-4378-b6ac-d9a95339e862"}}}], "length": {"value": 0.0188395, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "068b2a22-12d1-4431-9876-767c11d1380a", "name": "l(r:p1rdm67-p1rdt34lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "553a6868-acec-4492-a52d-5aa08414c612"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "713c1538-ceb4-46df-a996-6c591c0f8e40"}}}], "length": {"value": 0.009885930000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "57f5dec5-fde4-48bd-927b-f6e8e3ee8902", "name": "l(r:p1rdt35lv-p1rlv60)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f98cc066-fca3-4489-9770-047caee3e742"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7eb0d1e8-f85e-493e-b69b-26437fdb8ad9"}}}], "length": {"value": 0.0469606, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "dab845c7-99b1-4cc4-8b7b-5a2a0dd8bc4c", "name": "l(r:p1rdm69-p1rlv65)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23861598-ab3c-4648-9de9-3ee4316f2cb4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e00fd9b-92b3-49c4-bcc2-957b9d2c7bad"}}}], "length": {"value": 0.0500401, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "46a3c80f-7d6c-48a5-8c7e-9fbd9a1b6494", "name": "l(r:p1rdm69-p1rdt35lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f98cc066-fca3-4489-9770-047caee3e742"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23861598-ab3c-4648-9de9-3ee4316f2cb4"}}}], "length": {"value": 0.0188806, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9b42fd7d-449c-4d4e-adea-0857666843b0", "name": "l(r:p1rdt36lv-p1rlv63)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a4fb658-c3ba-428a-82bf-b38ae68dd908"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8300f90c-9a3b-400d-af04-072125dce84f"}}}], "length": {"value": 0.0205644, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b4da0dcf-1635-44fc-9cfa-33fecce7b0c4", "name": "l(r:p1rdm71-p1rlv64)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "074f23bd-2fb2-4480-ae4b-f1c1f754613e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5efd07ee-012a-40a4-97bb-07c1a5ed898c"}}}], "length": {"value": 0.0292333, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6bf40a82-f525-451a-b200-2331216a8321", "name": "l(r:p1rdm72-p1rlv162)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "590e467f-47a6-4c7e-ae3a-83cec8dd87e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3fcd1ee-e6e0-4ca3-aacf-cc527b07482a"}}}], "length": {"value": 0.0254773, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "11fdc903-3137-4c9b-940d-6dfaefc83a72", "name": "l(r:p1rdm71-p1rdm72)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "074f23bd-2fb2-4480-ae4b-f1c1f754613e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "590e467f-47a6-4c7e-ae3a-83cec8dd87e3"}}}], "length": {"value": 0.0457287, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1bba3325-6f85-4fd1-8d29-a1bf18d1c001", "name": "l(r:p1rdm71-p1rdt37lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90a16370-67f7-4abd-992c-990d1eb8f17e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "074f23bd-2fb2-4480-ae4b-f1c1f754613e"}}}], "length": {"value": 0.0378897, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1e35ea63-0b7a-4e0b-b5fa-533a1e06f848", "name": "l(r:p1rdm73-p1rlv457)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35807695-5d6d-4544-a748-a96c56b705d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6278f6ee-7332-4de8-9d2c-83bb637f489f"}}}], "length": {"value": 0.020988, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a802ba01-a073-46dc-a10c-aa18ea2dbc0e", "name": "l(r:p1rdm73-p1rdt37lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90a16370-67f7-4abd-992c-990d1eb8f17e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35807695-5d6d-4544-a748-a96c56b705d1"}}}], "length": {"value": 0.0568504, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "70ad305b-4b65-4e83-8e65-943e35a8510a", "name": "l(r:p1rdm74-p1rlv66)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "352f8404-f923-468a-92a5-1be2f82ffb97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e90eb8a2-5db0-4861-96ef-a6991a0386eb"}}}], "length": {"value": 0.0137711, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5adb5955-448c-40e5-95ec-8933d9be1689", "name": "l(r:p1rdm74-p1rdt38lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "752aca33-7682-4e8c-a8b1-624467e02958"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "352f8404-f923-468a-92a5-1be2f82ffb97"}}}], "length": {"value": 0.0186134, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "851de1c3-1505-4685-909f-6eddfe850ab2", "name": "l(r:p1rdm75-p1rlv68)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2332f175-22ca-4894-b63d-246f5c11c572"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c22aa2c8-a6fc-4b27-a875-e07e3f50ecac"}}}], "length": {"value": 0.0220855, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "eb01a68d-63ea-47e1-a68a-7afd7773560d", "name": "l(r:p1rdm75-p1rdt38lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "752aca33-7682-4e8c-a8b1-624467e02958"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2332f175-22ca-4894-b63d-246f5c11c572"}}}], "length": {"value": 0.0568453, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c0d8734c-4318-43b0-9e1e-c11ab3c1271b", "name": "l(r:p1rdm76-p1rlv69)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "131099af-6f69-4531-bebf-e457ff5d7624"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "876ffb0b-f33c-45b2-a085-7b34103ecffc"}}}], "length": {"value": 0.0355524, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "145e3aee-da52-4de2-a9a0-0cf95e1a2b11", "name": "l(r:p1rdm76-p1rdt39lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "623ec6b4-cb70-4437-9d79-5ec577bc3199"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "131099af-6f69-4531-bebf-e457ff5d7624"}}}], "length": {"value": 0.0177535, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "06a16ec9-6153-49da-a2be-542e268a7b4b", "name": "l(r:p1rdm77-p1rlv70)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a909c826-1682-47f0-926c-0a67c9ff2a3a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e53e7714-06d1-4f85-89c5-f152629e8ab7"}}}], "length": {"value": 0.0326608, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f396975a-7f86-4dd3-ad16-b797849c3c9b", "name": "l(r:p1rdm77-p1rdt39lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "623ec6b4-cb70-4437-9d79-5ec577bc3199"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a909c826-1682-47f0-926c-0a67c9ff2a3a"}}}], "length": {"value": 0.0177617, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5a53052c-73d6-4ee8-a0c2-559a73722330", "name": "l(r:p1rdt40lv-p1rlv143)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d08444c-79a3-4ba0-8c69-1855a600dea0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "46cd88d0-b2c4-492a-af3d-d9ae886d0089"}}}], "length": {"value": 0.016125500000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "482a0e0c-58d8-4958-aba7-344577c6f03f", "name": "l(r:p1rdm78-p1rlv71)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "435b1814-b0a6-40e3-a446-efe5b7fce133"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d7791de-0cf6-4901-8b95-2d67870f09f5"}}}], "length": {"value": 0.025679000000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2656656a-d2e7-49e3-9554-4cfd0e1b3ca5", "name": "l(r:p1rdm78-p1rdt40lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d08444c-79a3-4ba0-8c69-1855a600dea0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "435b1814-b0a6-40e3-a446-efe5b7fce133"}}}], "length": {"value": 0.0167754, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f87e81cc-c8a8-40ae-8e3f-0ac8561cdefe", "name": "l(r:p1rdt41lv-p1rlv72)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "793d0bf4-4d9f-4df4-bc95-d528dd7d31d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc710fc3-ae5f-478e-997b-85467db7c93c"}}}], "length": {"value": 0.02597, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e52746d2-07d5-4974-a61e-ff8b224c2504", "name": "l(r:p1rdt41lv-p1rlv88)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "793d0bf4-4d9f-4df4-bc95-d528dd7d31d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "188047cd-3f14-4240-91fe-30113d48152b"}}}], "length": {"value": 0.00984838, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6b64c3a9-ba1b-4cdf-ad7f-e5db328b835d", "name": "l(r:p1rdt42lv-p1rlv86)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8fb27dc9-b404-49d1-84dd-0cde418b037d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "540e0121-fc39-4c2c-9fbc-012c020f5994"}}}], "length": {"value": 0.0169027, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f58b52b9-f373-436c-9298-a94f37865466", "name": "l(r:p1rdm82-p1rlv73)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5f4300c-037f-42b5-a390-31ec1e8396b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4e2991c-1404-44da-bbb5-5a2ebc43bde4"}}}], "length": {"value": 0.025469700000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fd2626d9-6e6e-40a6-b779-ae761e65eaac", "name": "l(r:p1rdm86-p1rlv108)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5696ebea-257d-4cc1-9ae4-61c98563b706"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "afc70b80-ab76-440c-b05b-149458051675"}}}], "length": {"value": 0.05240000000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4cd09994-2b8e-4ac2-b56f-ee68addc1a41", "name": "l(r:p1rdm82-p1rdm86)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5f4300c-037f-42b5-a390-31ec1e8396b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5696ebea-257d-4cc1-9ae4-61c98563b706"}}}], "length": {"value": 0.0153424, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7708cca7-aa53-4b77-befd-c39e45b72c32", "name": "l(r:p1rdm82-p1rdt42lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8fb27dc9-b404-49d1-84dd-0cde418b037d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5f4300c-037f-42b5-a390-31ec1e8396b3"}}}], "length": {"value": 0.0153436, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e84c77e4-d941-4bb3-8e2f-0af560052a45", "name": "l(r:p1rdm83-p1rlv75)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49a07eb5-9c9b-479c-a345-b09f72725a21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ef51371-3fa2-400a-a2b4-3afa97ff2419"}}}], "length": {"value": 0.0103792, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "927bf580-0b67-4304-a620-9bc0dbd749e8", "name": "l(r:p1rdm83-p1rlv130)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49a07eb5-9c9b-479c-a345-b09f72725a21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5c96953-6710-4765-b5bd-4359e03e4c63"}}}], "length": {"value": 0.0354711, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "5634d407-bc77-4db0-b887-faa3d8d89dfd", "name": "l(r:p1rdm84-p1rlv79)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae45c08d-f629-4ff9-9c23-838b6e34da88"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4dd2283-6100-48ce-b4bc-0e37b7b4e409"}}}], "length": {"value": 0.0190078, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ead30048-de23-480f-aaa4-ed9fe5b1fc46", "name": "l(r:p1rdm87-p1rlv115)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d93360fa-3106-4444-9488-e73c6997ab71"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "919a48e8-b378-4dd5-8e33-a2602fb58bc0"}}}], "length": {"value": 0.0121631, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9d97061e-2727-4ac2-b9bf-80ebbfc55484", "name": "l(r:p1rdm84-p1rdm87)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae45c08d-f629-4ff9-9c23-838b6e34da88"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d93360fa-3106-4444-9488-e73c6997ab71"}}}], "length": {"value": 0.0078607, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "53544628-331d-4655-91a4-0552645c049b", "name": "l(r:p1rdm83-p1rdm84)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49a07eb5-9c9b-479c-a345-b09f72725a21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae45c08d-f629-4ff9-9c23-838b6e34da88"}}}], "length": {"value": 0.0149995, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1ac77898-6235-494c-b7f1-3d2c55ee09bb", "name": "l(r:p1rdm83-p1rdt42lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8fb27dc9-b404-49d1-84dd-0cde418b037d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49a07eb5-9c9b-479c-a345-b09f72725a21"}}}], "length": {"value": 0.0149938, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d4818ca2-9988-4682-8047-75b4f8e1b705", "name": "l(r:p1rdm90-p1rlv117)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b812c54c-1689-47cf-beba-55faea943380"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e6de569-7f61-439e-a402-850c4f071ab3"}}}], "length": {"value": 0.0134175, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "41a7ab78-9dfe-4430-89b0-f3ba5c13ff28", "name": "l(r:p1rdm90-p1rdt43lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "274aa0ec-f229-454c-b52d-23130bacb97e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b812c54c-1689-47cf-beba-55faea943380"}}}], "length": {"value": 0.0542235, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6bfac725-d1e2-41cf-ad2e-86634eae8994", "name": "l(r:p1rdm91-p1rlv137)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c82df28-72fa-4cf0-a844-8a6bf90e548b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54ca5205-5b71-42f2-8e24-c24f768a7a5c"}}}], "length": {"value": 0.0263424, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c4bc0a7f-44b6-4f0d-976c-999ec209e06f", "name": "l(r:p1rdm89-p1rlv74)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acbf36c3-9c53-417f-98c1-fa1b5d4b60f4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5861410e-9d6d-423e-b967-2f2af65610b8"}}}], "length": {"value": 0.0187311, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "83961bfa-b775-448b-8caf-405871623580", "name": "l(r:p1rdm89-p1rdm91)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c82df28-72fa-4cf0-a844-8a6bf90e548b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acbf36c3-9c53-417f-98c1-fa1b5d4b60f4"}}}], "length": {"value": 0.0145778, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d8f254e6-7113-400b-92d5-364565ba1e80", "name": "l(r:p1rdm91-p1rdt43lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "274aa0ec-f229-454c-b52d-23130bacb97e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c82df28-72fa-4cf0-a844-8a6bf90e548b"}}}], "length": {"value": 0.0145786, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "db357783-b1b2-4ffd-aca8-8ab881b6c351", "name": "l(r:p1rdt44lv-p1rlv76)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c813f8a2-226b-431d-a41a-195cf5e8b01a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3354497f-6de7-405d-9fca-a9c77463dc27"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "82e7c04e-ab13-4355-9b05-434f456065ad", "name": "l(r:p1rdm93-p1rlv77)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5151d03-c8b3-41f2-a2cd-743aa8ea0fea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f88a22a3-7e6c-4fc5-a8f4-a08cdaa3f5d6"}}}], "length": {"value": 0.0172005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ce7f90cf-c8da-460b-8111-0ea157b77973", "name": "l(r:p1rdm94-p1rlv119)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4dece5f0-ab6c-40ed-9ec6-0b1377d19e78"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee33d90b-2f70-4c9d-863d-6486b95280b8"}}}], "length": {"value": 0.0199779, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bd47d45f-500c-4c3d-8678-51a92d9023ea", "name": "l(r:p1rdm93-p1rdm94)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5151d03-c8b3-41f2-a2cd-743aa8ea0fea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4dece5f0-ab6c-40ed-9ec6-0b1377d19e78"}}}], "length": {"value": 0.0237669, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e1298125-2403-434a-b2db-9f772bc576f3", "name": "l(r:p1rdm93-p1rdt45lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e276abc-bb27-47e4-9de8-adaccbf964dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5151d03-c8b3-41f2-a2cd-743aa8ea0fea"}}}], "length": {"value": 0.0199888, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "96d5897f-f166-4bb2-8b66-3b7ba676cfe2", "name": "l(r:p1rdm95-p1rlv132)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a363b9b6-b80f-42cf-942e-17e723376ae6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41960437-e2e6-4746-89c2-81c81602ca1b"}}}], "length": {"value": 0.027088, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "79f574f4-b9a5-43f9-ab40-01e7afbc43b6", "name": "l(r:p1rdm95-p1rdt45lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e276abc-bb27-47e4-9de8-adaccbf964dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a363b9b6-b80f-42cf-942e-17e723376ae6"}}}], "length": {"value": 0.0399682, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "93d914a2-0ec3-414d-9502-25ee2a4943eb", "name": "l(r:p1rdm96-p1rlv78)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e93e7ed-6686-4fb2-8410-867f2cdbdab2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae76f058-b79a-4c0f-90be-f9cd7a02bcfc"}}}], "length": {"value": 0.032544800000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3e22d8ca-5f4b-48ed-afc3-1da29b5dce45", "name": "l(r:p1rdm97-p1rlv87)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdd576f2-a7e2-46eb-b2b0-818c4a97e694"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "46ee0e6c-daf7-4412-94a7-5332a6a97656"}}}], "length": {"value": 0.029464900000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e72d832f-a10c-4a41-bce6-db90e6a066d2", "name": "l(r:p1rdm96-p1rdm97)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e93e7ed-6686-4fb2-8410-867f2cdbdab2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdd576f2-a7e2-46eb-b2b0-818c4a97e694"}}}], "length": {"value": 0.0168832, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8cfe93c7-253e-4b6b-b392-aea42b09d08e", "name": "l(r:p1rdm96-p1rdt46lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aacdcb46-43e3-4147-ac25-3a9c1223e13a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e93e7ed-6686-4fb2-8410-867f2cdbdab2"}}}], "length": {"value": 0.018235, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "78991428-108e-4d6c-9398-41e4ca9a49db", "name": "l(r:p1rdm98-p1rlv138)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70024d6c-94dd-4367-aeec-92d4bc5eec04"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea9e5f8c-8477-403c-9d3a-911c4e5ab5c8"}}}], "length": {"value": 0.0236773, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c3c52273-2722-4a97-bd10-8e3dd59685c4", "name": "l(r:p1rdm98-p1rdt46lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aacdcb46-43e3-4147-ac25-3a9c1223e13a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70024d6c-94dd-4367-aeec-92d4bc5eec04"}}}], "length": {"value": 0.0547245, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d216af78-c172-4a19-a303-41195ec88d64", "name": "l(r:p1rdt47lv-p1rlv80)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f031530a-b3fc-4f8e-b0ac-139009d1256c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab7e1b4a-f8ec-4211-b7a0-d7f9057f576a"}}}], "length": {"value": 0.0117312, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "97d48ab3-ae67-4bb4-9933-c573d3b1b708", "name": "l(r:p1rdt47lv-p1rlv92)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f031530a-b3fc-4f8e-b0ac-139009d1256c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db8f484a-94d5-4d20-8ebf-6708b1601a0d"}}}], "length": {"value": 0.0191133, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "496ae067-3834-4768-96cc-4f91d6de96f4", "name": "l(r:p1rdt48lv-p1rlv81)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f1790fe-a399-46e3-b9e3-5979837777ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef92e40c-fe3c-4f7f-b844-884e1079e491"}}}], "length": {"value": 0.0151262, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "42788906-ee7c-4cb5-8863-6cdb7c3c583f", "name": "l(r:p1rdt48lv-p1rlv120)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f1790fe-a399-46e3-b9e3-5979837777ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a02925cd-7c5b-475f-9e91-30d639bb3c33"}}}], "length": {"value": 0.018014, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e6aee435-bc57-4b28-884d-c7734e4c64c1", "name": "l(r:p1rdm103-p1rlv122)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd7286c0-4c57-435f-bed2-fd9a927de8cc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b02739e-d082-4c54-8deb-8ccc83ab82ab"}}}], "length": {"value": 0.0117766, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "80537724-8dad-4e90-9c0f-536cfeb4f9aa", "name": "l(r:p1rdm103-p1rdt48lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f1790fe-a399-46e3-b9e3-5979837777ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd7286c0-4c57-435f-bed2-fd9a927de8cc"}}}], "length": {"value": 0.0197485, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0cac18f1-d0e4-45c0-9221-b52524ca2f6d", "name": "l(r:p1rdt49lv-p1rlv146)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e5bcc7e-f35c-4bbf-a7ff-a82817488b11"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da2538bd-189b-4699-823b-ed459d94b422"}}}], "length": {"value": 0.0323291, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "13eb61ae-13e2-4fcc-a1a7-33a49f742fef", "name": "l(r:p1rdm104-p1rlv82)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2409ced2-7817-40af-951f-33d725e9d75a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3ddd704-2530-4392-8e9e-06e047b12f41"}}}], "length": {"value": 0.018038, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0bf98212-8412-4b8c-8960-9f693eb62909", "name": "l(r:p1rdm104-p1rdt49lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e5bcc7e-f35c-4bbf-a7ff-a82817488b11"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2409ced2-7817-40af-951f-33d725e9d75a"}}}], "length": {"value": 0.0322986, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8527ab91-ca01-4884-958f-9bf6cadfb78d", "name": "l(r:p1rdm105-p1rlv107)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8385921-c183-4c26-bc99-bf5f0364c18b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "096e92a6-ea34-435e-a059-57d5234e1654"}}}], "length": {"value": 0.0143529, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "477a74e8-32b9-4d2f-8c62-4a8e287e6159", "name": "l(r:p1rdm105-p1rdt49lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e5bcc7e-f35c-4bbf-a7ff-a82817488b11"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8385921-c183-4c26-bc99-bf5f0364c18b"}}}], "length": {"value": 0.025904, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "eeb8dff2-6d0f-4edd-ab69-3e388cb798e4", "name": "l(r:p1rdt50lv-p1rlv127)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8208c617-caa9-46a5-b28a-8a5b0d9898a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ae7b1fe-08c4-4848-867e-e2426a325a99"}}}], "length": {"value": 0.0188957, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b4256583-e043-485c-b1d9-d6895fd573e8", "name": "l(r:p1rdm107-p1rlv83)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7948c980-abf7-4357-9ff8-4be9122a3167"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24c3e8d8-1520-4a05-84af-a70da6140b4d"}}}], "length": {"value": 0.02164, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "312ba1b5-d276-4196-b974-e562abef042c", "name": "l(r:p1rdm107-p1rlv123)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7948c980-abf7-4357-9ff8-4be9122a3167"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6184fe8d-ae60-426a-8c0c-a3cc56c5b67e"}}}], "length": {"value": 0.0223678, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ee3cd3d5-6ad3-46f8-be26-c622fe63b8e3", "name": "l(r:p1rdm107-p1rdt50lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8208c617-caa9-46a5-b28a-8a5b0d9898a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7948c980-abf7-4357-9ff8-4be9122a3167"}}}], "length": {"value": 0.01639, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d826c2fb-edda-469a-8669-c708580b5496", "name": "l(r:p1rdm110-p1rlv135)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2deeb6a-3ea7-44d9-9ee0-b013733dadc4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbdefe7a-517b-495b-88b8-dcf15a9429ff"}}}], "length": {"value": 0.0127473, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b029d869-0f98-49a8-ae56-7d0d5762a52f", "name": "l(r:p1rdm110-p1rdt50lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8208c617-caa9-46a5-b28a-8a5b0d9898a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2deeb6a-3ea7-44d9-9ee0-b013733dadc4"}}}], "length": {"value": 0.0164, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "205b7f88-30e3-477c-8222-63e49c3e5d9f", "name": "l(r:p1rdt51lv-p1rlv84)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09d7f030-a9b4-4705-82af-6cf140ba64d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "55e7538f-4bde-4810-a237-ac0cad7ba805"}}}], "length": {"value": 0.0456569, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "239e52d2-6f1c-4541-b593-743f536d2902", "name": "l(r:p1rdt51lv-p1rlv93)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09d7f030-a9b4-4705-82af-6cf140ba64d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0060c029-188f-4725-a935-8d0d9cc892f7"}}}], "length": {"value": 0.0305916, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a60d8329-112d-4656-b827-353773776f11", "name": "l(r:p1rdm113-p1rlv85)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5dd2d9f-42d5-48c4-b1e1-34ae6aa555df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcc52dd9-bacb-4e49-a057-d3747f89a7f7"}}}], "length": {"value": 0.0311927, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "5f3de303-599b-4841-99bd-cbb5d215b96a", "name": "l(r:p1rdm114-p1rlv91)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f42789f3-35c3-4d0d-adda-2044adce92c0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a1f01bc-d1f1-4d92-b1e2-1f8223624c52"}}}], "length": {"value": 0.0125623, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d83ba6fd-6457-4dda-a12d-dd5e09239ede", "name": "l(r:p1rdm113-p1rdm114)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5dd2d9f-42d5-48c4-b1e1-34ae6aa555df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f42789f3-35c3-4d0d-adda-2044adce92c0"}}}], "length": {"value": 0.0299732, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4d3d0323-36de-40d0-8acd-e15ce914b8e3", "name": "l(r:p1rdm113-p1rdt52lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c70a7331-8c41-4370-b053-3eae432d52ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5dd2d9f-42d5-48c4-b1e1-34ae6aa555df"}}}], "length": {"value": 0.0479351, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ebaf4901-4748-4e10-9bb6-f80772e1827b", "name": "l(r:p1rdm115-p1rlv94)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2d46cd2-9caf-47a7-b134-a29fccd91b9c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db2d4080-1f43-47a3-9f3a-e25d1e4f5076"}}}], "length": {"value": 0.0260186, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "55a80fa5-3bf1-418a-ad5c-7afa1fdf1e6c", "name": "l(r:p1rdm115-p1rlv103)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2d46cd2-9caf-47a7-b134-a29fccd91b9c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85afc796-3fe5-4027-b84e-10d502124636"}}}], "length": {"value": 0.0244121, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c44afe7e-8438-4d2c-a1e6-382731061903", "name": "l(r:p1rdm115-p1rlv144)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2d46cd2-9caf-47a7-b134-a29fccd91b9c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b7dbf54-f6bc-4e20-b2f3-8c63a44dd993"}}}], "length": {"value": 0.0176755, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f0aa2a13-e0c6-4712-8ce1-2b96b3454699", "name": "l(r:p1rdm116-p1rlv98)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0d6e82b-cba7-4c7e-8715-d73c3530bad7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "82f19d5c-0941-411d-8baa-3ba029471dae"}}}], "length": {"value": 0.0189352, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b9299fb3-8eb3-4d8c-beab-ef5d8bb3bd1a", "name": "l(r:p1rdm116-p1rlv136)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0d6e82b-cba7-4c7e-8715-d73c3530bad7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b45d086e-8e0d-42f4-a8ec-6d3a9579a96b"}}}], "length": {"value": 0.0258527, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "50eab12d-7e60-4f3e-86f8-77d7b63e1519", "name": "l(r:p1rdm115-p1rdm116)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2d46cd2-9caf-47a7-b134-a29fccd91b9c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0d6e82b-cba7-4c7e-8715-d73c3530bad7"}}}], "length": {"value": 0.012779, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1a90bcc3-121b-46ea-94ea-72690102cce8", "name": "l(r:p1rdm115-p1rdt52lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c70a7331-8c41-4370-b053-3eae432d52ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2d46cd2-9caf-47a7-b134-a29fccd91b9c"}}}], "length": {"value": 0.0312606, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a96a0a61-3593-4283-b799-abda634a973a", "name": "l(r:p1rdm122-p1rlv125)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "329f78a6-af13-4ceb-bc87-4660d497c22e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3367cc2-b096-4cfb-ae71-038eb9e06b46"}}}], "length": {"value": 0.027476800000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6105b98f-5c04-4aaf-8f0c-a630b2e674a6", "name": "l(r:p1rdm122-p1rlv148)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "329f78a6-af13-4ceb-bc87-4660d497c22e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa8af0a4-4d55-41e4-83d1-4fe349920e38"}}}], "length": {"value": 0.0149493, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "34c5ce67-2b3c-449c-a145-88ccef71510b", "name": "l(r:p1rdm121-p1rlv111)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d595142-3854-4152-b64a-6cda8396a523"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66748ae6-b6ef-4228-bb0f-f9a121f0e1a3"}}}], "length": {"value": 0.03370220000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f9ab571c-93e7-490b-be92-60d27d05330f", "name": "l(r:p1rdm123-p1rlv131)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2e27276-ea6c-40a3-92d3-4648ec9d235d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "499fb461-ccb6-436a-8078-eec9beffb4a9"}}}], "length": {"value": 0.0223731, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f08beed6-f030-42b2-b689-6fd6dffe7d03", "name": "l(r:p1rdm121-p1rdm123)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d595142-3854-4152-b64a-6cda8396a523"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2e27276-ea6c-40a3-92d3-4648ec9d235d"}}}], "length": {"value": 0.013548500000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6733f40f-da94-451d-ba9c-afc9bfd279e4", "name": "l(r:p1rdm121-p1rdm122)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "329f78a6-af13-4ceb-bc87-4660d497c22e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d595142-3854-4152-b64a-6cda8396a523"}}}], "length": {"value": 0.0118562, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "50295530-0eb2-46e9-b8d5-a2010ea2855a", "name": "l(r:p1rdm122-p1rdt53lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2536a0eb-a35c-40d4-9773-b78379e7481a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "329f78a6-af13-4ceb-bc87-4660d497c22e"}}}], "length": {"value": 0.0118562, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2688b58c-4fd5-467c-9a5a-8962e7d77466", "name": "l(r:p1rdm124-p1rlv141)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9f62740-f47f-4c97-bae7-4380fe83fcbc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb69a6a9-3eaf-4fc3-82be-0eec77455a82"}}}], "length": {"value": 0.0132542, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f0af7522-e5a1-45b8-a7fa-b575d9c6c63d", "name": "l(r:p1rdm120-p1rlv89)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1071344-55a0-4684-9fbf-5729ec1f21c2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24d75e9a-0249-48ca-ad10-32738bb6a519"}}}], "length": {"value": 0.010837, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c06a98a5-6584-47f6-80ff-d3e030eb948f", "name": "l(r:p1rdm120-p1rdm124)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9f62740-f47f-4c97-bae7-4380fe83fcbc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1071344-55a0-4684-9fbf-5729ec1f21c2"}}}], "length": {"value": 0.0349944, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7714abfb-4610-4b7d-9630-1be09cdc28fb", "name": "l(r:p1rdm124-p1rdt53lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2536a0eb-a35c-40d4-9773-b78379e7481a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9f62740-f47f-4c97-bae7-4380fe83fcbc"}}}], "length": {"value": 0.0174998, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e080f5fa-042f-4074-8eea-968559086793", "name": "l(r:p1rdt54lv-p1rlv90)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57889d14-4aac-4aee-a9e2-677a047e8054"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e06b2ac7-926e-4caf-afac-386910d4ea5e"}}}], "length": {"value": 0.05434540000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2e600f0e-d9b7-4e78-961b-8a6d0b046494", "name": "l(r:p1rdt54lv-p1rlv105)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57889d14-4aac-4aee-a9e2-677a047e8054"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fe82ede-430d-454d-b9d0-e212d0621ea1"}}}], "length": {"value": 0.0270168, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "26085e14-749e-4f2b-a8c0-be910144cf4c", "name": "l(r:p1rdt56lv-p1rlv96)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85ad3bf0-7e82-4e32-8106-faddcf725bdf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31508077-f731-47cb-94a9-869d7910e406"}}}], "length": {"value": 0.0243138, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d926d302-a341-4969-9971-0260425c8bef", "name": "l(r:p1rdm131-p1rlv804)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a60b127d-0530-495e-b3b9-2ebabf070fa1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a11ba246-99d9-4cf5-a557-bec53c75e6fb"}}}], "length": {"value": 0.0159541, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "23ec8047-b4d9-4836-9ad5-57087153b0b5", "name": "l(r:p1rdm131-p1rdt56lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85ad3bf0-7e82-4e32-8106-faddcf725bdf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a60b127d-0530-495e-b3b9-2ebabf070fa1"}}}], "length": {"value": 0.09807820000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3f894fd6-ef69-4853-be69-9ad20f68588d", "name": "l(r:p1rdm133-p1rlv99)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bf5bf18-363d-4f4e-bf10-9ffc601c0f30"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc4a448a-c6cb-4714-b8e6-b75bc6bc219c"}}}], "length": {"value": 0.0124594, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2680f81d-187f-458a-87c9-3e3af28acdaa", "name": "l(r:p1rdm133-p1rdt58lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3367c40-9f47-42d9-b627-bc502b170f2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bf5bf18-363d-4f4e-bf10-9ffc601c0f30"}}}], "length": {"value": 0.0166928, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "79b3a5aa-4572-4e8e-81ec-f62100bf8f85", "name": "l(r:p1rdm134-p1rlv101)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32e76273-c930-4506-9610-8cbfca04af67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48d1be49-5aca-4e18-8b85-2a1274b3f26d"}}}], "length": {"value": 0.027751, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e553c362-e091-4433-818b-930c420bf0a0", "name": "l(r:p1rdm134-p1rdt58lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3367c40-9f47-42d9-b627-bc502b170f2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32e76273-c930-4506-9610-8cbfca04af67"}}}], "length": {"value": 0.0166928, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "aab15890-22e5-493d-8c40-2a9eb3680b9c", "name": "l(r:p1rdm135-p1rlv100)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7b11b31-78f1-41fa-b511-df76daad0efc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62a0d673-eaba-4032-9038-8095e2d53999"}}}], "length": {"value": 0.0216228, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "045e775e-d108-4d2d-bff1-fd70db392191", "name": "l(r:p1rdm135-p1rdt59lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8aca9934-9439-4ce6-9ee3-475980324054"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7b11b31-78f1-41fa-b511-df76daad0efc"}}}], "length": {"value": 0.01639, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "299c7e4a-01dd-4183-8922-cd3a145251f0", "name": "l(r:p1rdm136-p1rlv121)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a415176a-ddab-47a0-9ce7-54c53c4c0f11"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0dbaab50-3abc-4207-82dc-5fcc5be68aad"}}}], "length": {"value": 0.024910800000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "def46ab3-205a-44d1-8334-ca8d8e6177c4", "name": "l(r:p1rdm136-p1rdt59lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8aca9934-9439-4ce6-9ee3-475980324054"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a415176a-ddab-47a0-9ce7-54c53c4c0f11"}}}], "length": {"value": 0.018122, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0a52364f-f121-431c-a2b3-2b5afc7a1064", "name": "l(r:p1rdt60lv-p1rlv102)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2517cea-05d3-4b7f-b9fc-0df0fde81235"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06a432e3-dd37-4c52-b954-6652bb529c8e"}}}], "length": {"value": 0.027151, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "45d4171e-dfd6-4632-a1f4-1631c7bb39fb", "name": "l(r:p1rdm138-p1rlv104)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e53344e0-e328-4acd-b159-e1f8cc246996"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c76c5b8f-1994-470c-a024-b97c73b9bb41"}}}], "length": {"value": 0.024191, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fd16c16e-bcb3-49ac-b2c8-5b3f035f1a47", "name": "l(r:p1rdm138-p1rdt61lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70f11a44-826f-45b8-9dc3-0f51ce6c9733"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e53344e0-e328-4acd-b159-e1f8cc246996"}}}], "length": {"value": 0.031133800000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8f90a935-dde4-4055-911b-e8879ea22ef8", "name": "l(r:p1rdm139-p1rlv124)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "022bda10-6b1a-408b-a231-adb63e189d14"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e5ca78b-6151-4a35-8a04-1bab215f0f10"}}}], "length": {"value": 0.0139389, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ff500abb-a8c2-406e-b3f7-762556f3baf4", "name": "l(r:p1rdm139-p1rdt61lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70f11a44-826f-45b8-9dc3-0f51ce6c9733"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "022bda10-6b1a-408b-a231-adb63e189d14"}}}], "length": {"value": 0.04687960000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "229322ea-6622-4b66-b281-0c2279fd872b", "name": "l(r:p1rdt63lv-p1rlv109)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fac6d4e1-b14d-4973-9626-6a4bde2d2a42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c76fc99c-c160-4ed0-85dd-ec3da962bb24"}}}], "length": {"value": 0.0188407, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "29137b68-38a0-4299-9224-4de2da7e7ec2", "name": "l(r:p1rdt63lv-p1rlv112)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fac6d4e1-b14d-4973-9626-6a4bde2d2a42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25edc94b-a44b-4200-8cde-73941c2818b8"}}}], "length": {"value": 0.04148810000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "90fa423f-c3aa-41a3-b1ff-5e27be2447cf", "name": "l(r:p1rdm143-p1rlv139)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21b14d95-6634-4f0e-a380-d5e57328d825"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b515111-3455-471a-aba8-92c82624a195"}}}], "length": {"value": 0.0108102, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "34f808d1-99d2-4282-862a-0ada3cd93d88", "name": "l(r:p1rdm143-p1rdt63lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fac6d4e1-b14d-4973-9626-6a4bde2d2a42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21b14d95-6634-4f0e-a380-d5e57328d825"}}}], "length": {"value": 0.016739300000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4283d362-7320-4954-872c-29955cf66239", "name": "l(r:p1rdm145-p1rlv113)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09182ca9-8ea2-4d1c-9c3e-5850a77c1b66"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2756378a-0c67-47cf-969d-bdb9e55c8a4b"}}}], "length": {"value": 0.020074400000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "040ec575-fb08-4511-ad29-6f7f2a4d7af6", "name": "l(r:p1rdm145-p1rlv128)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09182ca9-8ea2-4d1c-9c3e-5850a77c1b66"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56bc8935-c658-424c-83d8-0d13bf8d292a"}}}], "length": {"value": 0.0115543, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c1b08193-75f8-4a5a-bf68-d42b893314b1", "name": "l(r:p1rdm145-p1rdt65lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ae9cb89-7cb8-48c6-a5bc-4178ee364ae8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09182ca9-8ea2-4d1c-9c3e-5850a77c1b66"}}}], "length": {"value": 0.0459314, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0091adf2-477d-4aec-bab4-b4f1d4f1e4bd", "name": "l(r:p1rdm147-p1rlv838)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "de7551d6-5168-440c-8fe2-9f17e0904c29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7ffe87d-4424-4495-83c1-6765d385207c"}}}], "length": {"value": 0.0255431, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8d2187a7-f961-459a-84c8-fd146db95437", "name": "l(r:p1rdm147-p1rdt65lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ae9cb89-7cb8-48c6-a5bc-4178ee364ae8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "de7551d6-5168-440c-8fe2-9f17e0904c29"}}}], "length": {"value": 0.0470531, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2ae9cae5-3620-485e-bc07-7fb5feee034e", "name": "l(r:p1rdt66lv-p1rlv114)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfb9fa3b-c758-4c2e-bc51-f297b1ed21bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7934cd3-dcd6-4b67-8206-8a3636b6f75d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "8024cb11-d099-42e8-a763-d30f1bb4a619", "name": "l(r:p1rdt68lv-p1rlv118)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd2d6296-a302-4027-9e5f-c24a56a1a1ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "247e37b3-d6d0-41d7-a6b3-ee29d415da50"}}}], "length": {"value": 0.059931, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "145aef75-cb5e-433d-8d5a-8361f88a52f2", "name": "l(r:p1rdt69lv-p1rlv129)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7057debb-bd4d-4156-a253-0f3a14cdd784"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6c42586-4f46-45c6-910f-90fca771cfd2"}}}], "length": {"value": 0.0182448, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "07a96d7b-4253-4b07-938f-5f40eb0597b4", "name": "l(r:p1rdt69lv-p1rlv140)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7057debb-bd4d-4156-a253-0f3a14cdd784"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47b7d9f8-ca72-4a77-af67-74ee561f7f10"}}}], "length": {"value": 0.0205388, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "326b2815-73fb-47a1-b2b2-e52a6009bae3", "name": "l(r:p1rdt70lv-p1rlv133)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02440066-bc62-4629-96c5-4b497827de5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31dc8280-eb14-4f87-85d7-8eae17013fe7"}}}], "length": {"value": 0.027257900000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0896fb8c-8a94-4a92-8427-e52dd8da6f11", "name": "l(r:p1rdm155-p1rlv134)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43d5d2c5-10f6-4e89-91fa-5186f269b659"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "425bdcfa-9753-4ef5-bb38-9e014ae779dc"}}}], "length": {"value": 0.0117214, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "67b0fa5c-c109-4dc4-a7e5-8a596918e2c5", "name": "l(r:p1rdm155-p1rdt71lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e71f106d-4b41-405f-bce9-3d06b336a554"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43d5d2c5-10f6-4e89-91fa-5186f269b659"}}}], "length": {"value": 0.024182, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "68303935-f043-4a5f-ae67-0cef20dd642e", "name": "l(r:p1rdm156-p1rlv145)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8357e543-eba0-4863-9d95-e34d84a3fae7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1704e67-dfa3-4a6b-a3f4-7ebba9d27537"}}}], "length": {"value": 0.014900100000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bfa069fa-7070-4e5b-b9aa-1521209b1000", "name": "l(r:p1rdm156-p1rdt71lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e71f106d-4b41-405f-bce9-3d06b336a554"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8357e543-eba0-4863-9d95-e34d84a3fae7"}}}], "length": {"value": 0.013317800000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5900d375-7f71-4fe1-a29a-4d36a9287091", "name": "l(r:p1rdt72lv-p1rlv147)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b59eeab-d997-4186-ab59-0424644d5aeb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "070d9a60-c6f2-424c-bd0f-66c52d349f0c"}}}], "length": {"value": 0.021214800000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "35f35705-9799-435b-ae55-94c357a8cb75", "name": "l(r:p1rdm158-p1rlv149)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35f3fd4d-f962-4e4e-89d8-8b41a07ff57d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "063e89ea-6dd0-404f-abfb-21686f3041ed"}}}], "length": {"value": 0.0223159, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "88271973-bd02-47cf-8ce6-9297ca915d33", "name": "l(r:p1rdm158-p1rdt73lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f027d15-df82-4989-93e5-a3b40c862b08"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35f3fd4d-f962-4e4e-89d8-8b41a07ff57d"}}}], "length": {"value": 0.0177535, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "94aed7aa-d694-4d27-ac2a-69f72d010664", "name": "l(r:p1rdm159-p1rlv167)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b8d2667-d52b-46b3-ace4-2ad2b4e3050e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5187e006-621e-4c15-9604-0272ae62887c"}}}], "length": {"value": 0.0172799, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3f4794ef-c7bb-47ed-ae29-ece483a30c44", "name": "l(r:p1rdm159-p1rdt73lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f027d15-df82-4989-93e5-a3b40c862b08"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b8d2667-d52b-46b3-ace4-2ad2b4e3050e"}}}], "length": {"value": 0.0177535, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9a4c7fc8-af6b-46fd-a354-08371ebfcf7e", "name": "l(r:p1rdm160-p1rlv150)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb4a799f-0e03-4ba6-b8ce-8f5e117fd2c2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b9979ec-4e43-4feb-a617-28191e9dd9d8"}}}], "length": {"value": 0.023161300000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d7a1bde2-f7a2-4d8d-8c90-3c65fbc01fba", "name": "l(r:p1rdm160-p1rdt74lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37880102-8a9c-4f7b-930a-b29a94241866"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb4a799f-0e03-4ba6-b8ce-8f5e117fd2c2"}}}], "length": {"value": 0.0168665, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4d2c8db5-28f9-42a7-b24f-191844d2df53", "name": "l(r:p1rdm161-p1rlv169)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "243cdb10-5012-48b5-809f-1952913bf655"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e326756-7ead-4099-a065-9f2de5693197"}}}], "length": {"value": 0.0219801, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "dfdccb19-3918-4a66-8ff9-42e75bc5e315", "name": "l(r:p1rdm161-p1rdt74lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37880102-8a9c-4f7b-930a-b29a94241866"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "243cdb10-5012-48b5-809f-1952913bf655"}}}], "length": {"value": 0.0168563, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "94875e3d-2424-4911-a398-14b27da184b9", "name": "l(r:p1rdt75lv-p1rlv151)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "699bbf24-59ba-4dba-8bd4-1cf04a7e6e47"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "345b5c48-cd35-418e-bc08-50c06f5dff09"}}}], "length": {"value": 0.0195504, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a9a39282-bd02-4e82-ad57-8abf21c4bad6", "name": "l(r:p1rdt76lv-p1rlv154)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ecf2223-f120-45b4-8aab-a36d60161aec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ccdfbc7-d3a6-4f74-ad32-25ff11a2e3b7"}}}], "length": {"value": 0.013038, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "84f9badb-2feb-4fc0-9f7b-2e8a011fde0b", "name": "l(r:p1rdm163-p1rlv153)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0bd295ef-2c38-4c6b-915a-73900e920b92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ebbe09dd-7560-4eff-9e32-803f14b4ce7c"}}}], "length": {"value": 0.0190604, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9844c82d-1619-481b-9355-a508b593d8f2", "name": "l(r:p1rdm163-p1rdt76lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ecf2223-f120-45b4-8aab-a36d60161aec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0bd295ef-2c38-4c6b-915a-73900e920b92"}}}], "length": {"value": 0.0157338, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "79b6b890-dc64-4ae0-82bd-de9ffbe2e0de", "name": "l(r:p1rdt77lv-p1rlv155)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3fd9bf7-ecdd-4dcb-966a-f426d5f2ee81"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2452d5af-5aba-4d4b-8cd9-27a95fe6b34d"}}}], "length": {"value": 0.023128200000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "98981286-258e-4c7d-9452-c6c98e2b96a6", "name": "l(r:p1rdm166-p1rlv156)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e110db24-1653-41b5-8496-821dfff05769"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f607e6b-9540-4845-9f0c-6c334eb0e807"}}}], "length": {"value": 0.0182012, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8f778f87-7e35-45ec-984f-a71d2d2552a6", "name": "l(r:p1rdm166-p1rdt78lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f0255b7-5369-40eb-8814-959b0d4245b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e110db24-1653-41b5-8496-821dfff05769"}}}], "length": {"value": 0.0187893, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "29265848-23e0-4b5f-bc67-c3a69b4ec89d", "name": "l(r:p1rdm167-p1rlv159)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c108a0c2-3093-4222-9547-5ac08f6d8a4a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0ae6c02-c29e-4bf9-b1d4-ecc7e37e7de2"}}}], "length": {"value": 0.0190142, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "70765cfe-bcf3-4651-aef0-ba765d84ad6a", "name": "l(r:p1rdm167-p1rdt78lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f0255b7-5369-40eb-8814-959b0d4245b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c108a0c2-3093-4222-9547-5ac08f6d8a4a"}}}], "length": {"value": 0.0238255, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "169b1bc9-8c2a-45ba-8108-75b0f300554e", "name": "l(r:p1rdt79lv-p1rlv164)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "624d03d5-ac53-4d58-ac86-62834fa13c61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61460072-bdc5-4a70-96fa-8ecfa71623f4"}}}], "length": {"value": 0.0140409, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "289216e0-4528-483f-acbb-e2f23d34c2c3", "name": "l(r:p1rdm168-p1rlv157)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "937989ee-4525-4394-b04f-37d77a2c910c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4355a473-4643-4f72-afe8-80ce773ca8e8"}}}], "length": {"value": 0.030818, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9f6477d9-5d1d-40fe-bb83-7e5a13092058", "name": "l(r:p1rdm168-p1rdt79lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "624d03d5-ac53-4d58-ac86-62834fa13c61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "937989ee-4525-4394-b04f-37d77a2c910c"}}}], "length": {"value": 0.012795000000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bb55e3ed-4ff8-4c38-8295-e3849dbb9b29", "name": "l(r:p1rdt80lv-p1rlv158)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ce05c72-facf-447f-ba14-cc2ef64579a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1cd7284-17fb-4382-a29d-dd8c5bfd7541"}}}], "length": {"value": 0.020056, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "09956226-9e3a-4f6d-9b35-faa0073f0f10", "name": "l(r:p1rdt81lv-p1rlv160)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b610625-09e3-4b72-a8fe-b0c36f5e137c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd2fae5a-e5dd-4ad4-8acc-422de00ae83e"}}}], "length": {"value": 0.0130169, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3eead181-f910-4fda-a540-6d31c233bba1", "name": "l(r:p1rdm172-p1rlv161)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2dad274-0d92-42fa-bf1e-a22af034211f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4842819e-3f17-47da-a8bf-c3402c3c00b7"}}}], "length": {"value": 0.0198598, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9f5ed50e-7216-4609-8db5-2605f3480b51", "name": "l(r:p1rdm172-p1rdt82lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9872669f-fd85-458a-8951-ec12965fb42b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2dad274-0d92-42fa-bf1e-a22af034211f"}}}], "length": {"value": 0.0233983, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0c3c8219-32ba-4305-986d-9d50b230171f", "name": "l(r:p1rdm173-p1rlv830)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44bdfec0-2d44-442d-b562-ac786c61a76a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b7538477-32ab-4db6-872d-83be7ec89fd9"}}}], "length": {"value": 0.016941, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2e07e867-c355-4586-876e-f4e62cece9b3", "name": "l(r:p1rdm173-p1rdt82lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9872669f-fd85-458a-8951-ec12965fb42b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44bdfec0-2d44-442d-b562-ac786c61a76a"}}}], "length": {"value": 0.0146175, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fb158784-8660-4b98-bebd-f836c1d4238d", "name": "l(r:p1rdt83lv-p1rlv163)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8dac1e07-5eb6-4945-a3d9-95b77310358d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "471bad88-4514-4b02-aa1a-1d2aaa15557f"}}}], "length": {"value": 0.021129600000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "92015457-1970-4062-ad0b-862739545707", "name": "l(r:p1rdm175-p1rlv165)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9de64e4-b140-4526-af3c-1f7ceaa687bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e7880c9-0932-4395-abf9-2274e400f280"}}}], "length": {"value": 0.0440542, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6b3be467-1489-413f-8884-dffbbb55fcb7", "name": "l(r:p1rdm175-p1rdt84lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdb8aaf1-0e21-42e0-a72d-666646561235"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9de64e4-b140-4526-af3c-1f7ceaa687bf"}}}], "length": {"value": 0.0128709, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "476a440b-2b65-427e-9160-56b6f9589207", "name": "l(r:p1rdm176-p1rlv166)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a6bf0b9-809d-48fb-b8bd-375df052b6cc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21d333f7-7426-4fa6-8ab2-c6118055ece1"}}}], "length": {"value": 0.0268124, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "77c0c35b-8ab2-45bb-9665-5cfb22ed9809", "name": "l(r:p1rdm176-p1rdt84lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdb8aaf1-0e21-42e0-a72d-666646561235"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a6bf0b9-809d-48fb-b8bd-375df052b6cc"}}}], "length": {"value": 0.014891, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a0cb5616-3b4a-4ef2-a418-0f34f92e5cde", "name": "l(r:p1rdt85lv-p1rlv168)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40f4034e-c735-419b-80cd-d729d75f4692"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "470fe3ed-5b24-438a-ba6d-cdd9f774e5ad"}}}], "length": {"value": 0.0181757, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "60e2ab6d-9475-4352-8dff-e83ebfd55fd3", "name": "l(r:p1rdt89lv-p1rlv174)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1186295-59ff-48a8-b31d-0f7cd40df1ab"}}}], "length": {"value": 0.059378900000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b34af2ca-a059-4e01-93f4-75562afe5d6a", "name": "l(r:p1rdt89lv-p1rlv175)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905e9287-bdb6-44e0-b0af-f59ab4ad4d8e"}}}], "length": {"value": 0.0220486, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7a00cf1f-e224-44c2-b130-ae181cbc684b", "name": "l(r:p1rdt89lv-p1rlv176)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "931c8cee-89fe-447d-8788-af1e5f9f8775"}}}], "length": {"value": 0.0331252, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "5cbc1082-febb-4953-b261-752d2c159e74", "name": "l(r:p1rdt89lv-p1rlv177)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "090d6084-5cc6-473d-99c0-a6309571d633"}}}], "length": {"value": 0.053761, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b428ecd9-3158-4565-9fd1-6e401d34c594", "name": "l(r:p1rdt89lv-p1rlv178)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9debf70-62f4-4870-ad8b-bffc4bc4ad3f"}}}], "length": {"value": 0.0259912, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "81c89f55-1e6d-495b-a730-bfcacf30aafe", "name": "l(r:p1rdt89lv-p1rlv179)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb03260b-d7d7-4779-ab2c-37c9a1e34d66"}}}], "length": {"value": 0.0485967, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0f9cbb19-2251-459a-8fef-5974f0e19e65", "name": "l(r:p1rdt150lv-p1rlv285)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d156fdde-5620-4a6f-b8c1-a3ab986fcc88"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d3a86df-2ac5-4959-b857-562795ce84ba"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "a7fc4ccd-23ad-4d23-9c5d-01f39107d778", "name": "l(r:p1rdt177lv-p1rlv337)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d64d858-a9f7-430f-890e-a456f8913c30"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57b88281-b728-4779-82b1-4cc9eb4b41b1"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "6fe53808-07ef-4c59-8888-4ecf921fbd4a", "name": "l(r:p1rdt178lv-p1rlv338)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3314fa8-a838-4028-abb5-043425fd0785"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6b2aba6-a289-4a50-a131-2064047d1341"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "c2486b9c-458d-4c7d-a30b-2005a6509c49", "name": "l(r:p1rdt180lv-p1rlv340)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3e633bc-311e-4698-a413-9c6cf09c42a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb4797d6-b46e-4058-8985-d9f4b660f0a7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "bd6ee48d-28b5-4315-aa01-18786c9521fd", "name": "l(r:p1rdt181lv-p1rlv341)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05401825-91f8-41f8-9204-ab5806458594"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54f0ea2c-3849-4ff0-ad8c-e3f65515d178"}}}], "length": {"value": 0.0184707, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1b31f96a-78eb-4c21-a342-8e9911075c8f", "name": "l(r:p1rdt181lv-p1rlv342)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05401825-91f8-41f8-9204-ab5806458594"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13754fdb-4039-49fb-b584-8437191dfb2b"}}}], "length": {"value": 0.0184707, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6268230d-7e2d-460a-a71c-f4728aeb6115", "name": "l(r:p1rdt182lv-p1rlv343)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db407ddd-fb81-4767-99e1-9aeab12fc770"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0197ef22-9f8f-48a9-84de-663a7ce22773"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b1a02585-8b94-4e80-b57f-1077bfeba63f", "name": "l(r:p1rdt209lv-p1rlv377)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4724ea16-dc31-48f8-98b8-b9a223e9a4bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e1ea241-5329-4db5-996a-df09a9c25687"}}}], "length": {"value": 0.0107399, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "956ab7d4-2958-436c-a13d-ffd2364dc552", "name": "l(r:p1rdt209lv-p1rlv379)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4724ea16-dc31-48f8-98b8-b9a223e9a4bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50225dcf-40bc-44b5-9dec-072ac5b2334e"}}}], "length": {"value": 0.0107399, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2f7cb6af-5e60-46b7-9658-4724b60445a0", "name": "l(r:p1rdt210lv-p1rlv378)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05f6a3bf-d465-4f16-8205-616d1f4dd465"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3ff63a0-bf3f-43b0-807c-935467b4fe46"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "cf7a4cd4-9ab0-4b90-838b-e3dc4f53c107", "name": "l(r:p1rdt211lv-p1rlv380)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1d5af6ce-9a4c-414a-bbd8-15d82f50cb57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ee07ef9-b7b0-4457-be1c-78e754dbcfc7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "d5ffdfd7-04b1-491f-96ab-1d221c5a2721", "name": "l(r:p1rdt233lv-p1rlv415)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "591461d4-20da-4165-a210-4dbaedd81016"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b54aae8-5a94-4e04-882f-748e1c5f1390"}}}], "length": {"value": 0.0211272, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0505f748-32fd-40ee-adcc-f8ae4f7aa5e0", "name": "l(r:p1rdt233lv-p1rlv416)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "591461d4-20da-4165-a210-4dbaedd81016"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99abc7dc-8e15-420f-9bc9-0e6229d4dab3"}}}], "length": {"value": 0.0170787, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3e94a0ef-755f-4c61-8339-9228a6a9a348", "name": "l(r:p1rdm434-p1rlv412)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "019c88af-413c-4331-84f7-923a1df0a303"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b33ed36-116b-4741-9374-6927bd537427"}}}], "length": {"value": 0.0284617, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c321be1c-7377-4681-bef4-1a0174a2eae3", "name": "l(r:p1rdm434-p1rdt233lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "591461d4-20da-4165-a210-4dbaedd81016"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "019c88af-413c-4331-84f7-923a1df0a303"}}}], "length": {"value": 0.0343908, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6be33d65-8fea-460c-a84a-a0e3f510cfd2", "name": "l(r:p1rdm437-p1rlv419)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3b3eb51-c011-4f2c-8a10-c43c9c86217b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7935b9c-b631-432c-a322-9beea73f1fc4"}}}], "length": {"value": 0.0215859, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "98182c6b-dfb8-473b-8d57-952c06f1388d", "name": "l(r:p1rdm438-p1rlv420)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a713d96-e13f-447e-ab9f-012af3e26afe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4d7ed8-5ddd-4127-87ab-eb3f48a580c2"}}}], "length": {"value": 0.0147074, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "befe0c14-01c2-4b06-a7f9-2a47fc69e8cb", "name": "l(r:p1rdm437-p1rdm438)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3b3eb51-c011-4f2c-8a10-c43c9c86217b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a713d96-e13f-447e-ab9f-012af3e26afe"}}}], "length": {"value": 0.0117282, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "578c6339-ef3b-4716-adb1-a9e5b3ed6b05", "name": "l(r:p1rdm437-p1rdt233lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "591461d4-20da-4165-a210-4dbaedd81016"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3b3eb51-c011-4f2c-8a10-c43c9c86217b"}}}], "length": {"value": 0.0343908, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "42624629-eac1-4745-adf2-53d1be42e2d3", "name": "l(r:p1rdm439-p1rlv413)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "adb2d039-e162-43f7-8498-1374581a75fc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8408ac87-a086-46bc-9d88-cca79e17dd62"}}}], "length": {"value": 0.015615700000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5b4cc8dc-fc2d-4cb2-a6bd-7786ab4a81a2", "name": "l(r:p1rdm439-p1rdt234lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e480f304-b192-4107-91e1-131d481657b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "adb2d039-e162-43f7-8498-1374581a75fc"}}}], "length": {"value": 0.0177624, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e091d378-1707-46e2-9007-81ca0fb1783d", "name": "l(r:p1rdm440-p1rlv417)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84570b2e-efeb-477e-be1c-43b9d2922fda"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49dbdd44-a36a-46b5-aef8-558ef7693315"}}}], "length": {"value": 0.0243364, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "808b2de4-c291-4a98-bf76-253fbf95aa27", "name": "l(r:p1rdm440-p1rdt234lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e480f304-b192-4107-91e1-131d481657b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84570b2e-efeb-477e-be1c-43b9d2922fda"}}}], "length": {"value": 0.0354523, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f7407667-b6d5-4229-a8a0-b06a8bc055e6", "name": "l(r:p1rdt235lv-p1rlv421)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d8a6708a-d098-4e02-aac6-4aba7fdc71a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12dcb168-1bfe-448b-8d9a-f5cb4c61aafe"}}}], "length": {"value": 0.015099000000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8b295164-05a6-4f11-95bb-179fa6784c17", "name": "l(r:p1rdt236lv-p1rlv422)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7dd709e3-c5ec-4a01-8297-11f4d1261c3a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa7bb51b-8ba8-4a05-872a-7f5ce084fe88"}}}], "length": {"value": 0.0221266, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8526a0f0-81c9-4b1e-b0fd-6ca440c0c355", "name": "l(r:p1rdt236lv-p1rlv423)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7dd709e3-c5ec-4a01-8297-11f4d1261c3a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c1e9680-f7de-497c-953a-54f4db2899e2"}}}], "length": {"value": 0.013832, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "85e410b3-3fd8-4adf-b912-606c69de0cc1", "name": "l(r:p1rdt237lv-p1rlv424)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b72726f3-250c-4d98-86bc-5120137bd0f1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1a91c8c-aabd-4fad-8306-908f186a5744"}}}], "length": {"value": 0.0173984, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "63a6ee4f-9a39-4d73-94c7-2011f40c3e2a", "name": "l(r:p1rdt237lv-p1rlv449)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b72726f3-250c-4d98-86bc-5120137bd0f1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "753035df-8705-48eb-92b3-c4bef603b66b"}}}], "length": {"value": 0.0173984, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7090fbe2-cb8c-4c09-b6fa-da9414b54b2b", "name": "l(r:p1rdt251lv-p1rlv439)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42dff28c-89e7-4b56-bf23-3dcdd3ca216f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f771660-4dad-43df-b38b-7da5f6180a25"}}}], "length": {"value": 0.0641388, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d8826333-a219-4797-a8d9-92cd616ce986", "name": "l(r:p1rdt251lv-p1rlv445)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42dff28c-89e7-4b56-bf23-3dcdd3ca216f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d665758-71e1-4478-b39d-671f78f623e5"}}}], "length": {"value": 0.05250030000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f668b2d1-629e-440a-bc89-69bb83227759", "name": "l(r:p1rdt251lv-p1rlv446)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42dff28c-89e7-4b56-bf23-3dcdd3ca216f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acce3105-f519-491c-921a-df1294795742"}}}], "length": {"value": 0.0829969, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "bba4004f-1129-4d09-95ca-69a606870bc4", "name": "l(r:p1rdt251lv-p1rlv447)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42dff28c-89e7-4b56-bf23-3dcdd3ca216f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "042873fa-10df-4de0-a040-ac429b8bf7d9"}}}], "length": {"value": 0.0834464, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3ec5458c-b354-433b-a8d4-78268d281508", "name": "l(r:p1rdt251lv-p1rlv448)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42dff28c-89e7-4b56-bf23-3dcdd3ca216f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bb83d65-630d-4f1d-8e3d-8937a5a05524"}}}], "length": {"value": 0.0573344, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ad0a49de-fc5d-4d28-b860-b1a01394e3bc", "name": "l(r:p1rdt253lv-p1rlv441)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "704fece3-3b83-4c0b-bcd1-d463b3cdaf6b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a778b00-482c-4b81-8213-f17202a105fa"}}}], "length": {"value": 0.0393745, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e5b3ae7c-65ec-457c-83b8-b09122a326b0", "name": "l(r:p1rdt253lv-p1rlv444)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "704fece3-3b83-4c0b-bcd1-d463b3cdaf6b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30f29674-3083-4da2-95e2-a1f11a7eb7f8"}}}], "length": {"value": 0.0393745, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "66809432-ac15-4760-9231-6d4f6bfb9cf9", "name": "l(r:p1rdt254lv-p1rlv442)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "655d8f44-aa2f-4548-a1ca-83fcce9fa7aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cd667a9-c0ef-49ce-b6ee-7e474d9ae761"}}}], "length": {"value": 0.0182025, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "51d246f9-90d4-4835-bc50-b80c39ceacd0", "name": "l(r:p1rdt254lv-p1rlv443)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "655d8f44-aa2f-4548-a1ca-83fcce9fa7aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2100c17-c0e6-47e9-87f8-72016b22dd4b"}}}], "length": {"value": 0.0182025, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d0823786-024b-4ce4-a47b-e9ad39c63732", "name": "l(r:p1rdt257lv-p1rlv452)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4c28500-44f7-47c6-b8a8-d1e3468494e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb46f1ae-0cdb-45d1-b389-639cdf345f8e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "f289f501-a893-432d-90a7-87d93c77ec10", "name": "l(r:p1rdt258lv-p1rlv453)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad9ffaef-f21b-43da-9f67-3a8271edb6bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6a8a3c7-5165-48b7-8233-30d3af045442"}}}], "length": {"value": 0.0230491, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5c20bbe4-9be1-430f-95f9-596fa613a6e9", "name": "l(r:p1rdt258lv-p1rlv456)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad9ffaef-f21b-43da-9f67-3a8271edb6bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85f0d94e-c096-4d53-ae05-f0dc59f73d02"}}}], "length": {"value": 0.0595648, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0246e7a2-f298-4214-816f-1f9560d5c268", "name": "l(r:p1rdt258lv-p1rlv460)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad9ffaef-f21b-43da-9f67-3a8271edb6bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76b212f9-2e27-4064-a2c5-079786afb1d1"}}}], "length": {"value": 0.0369882, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "647e9cbe-c03f-424e-a989-fff636f9df75", "name": "l(r:p1rdt259lv-p1rlv454)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6a0feb3-78c1-4d69-8d18-2a8c3abdcf54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3493b0ed-43a2-4602-a7ad-a817331c9d8e"}}}], "length": {"value": 0.007000180000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b2c6818b-63e4-4176-97f7-3725e51b766d", "name": "l(r:p1rdt259lv-p1rlv455)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6a0feb3-78c1-4d69-8d18-2a8c3abdcf54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "552153cc-f5be-42ee-9985-9361c2e7e2a1"}}}], "length": {"value": 0.007000180000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "802e828a-0585-47a2-b9f3-0de5df57c988", "name": "l(r:p1rdt260lv-p1rlv458)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d8d796d8-6750-4ca5-ae07-1b07331ce6ee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec66e302-748d-4300-ba65-719de0a906bb"}}}], "length": {"value": 0.0434176, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "46c807d5-43c5-4672-a3dd-a19e5d31c13a", "name": "l(r:p1rdt260lv-p1rlv461)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d8d796d8-6750-4ca5-ae07-1b07331ce6ee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76dd0f1b-4109-4707-a547-f0ab1b6e148f"}}}], "length": {"value": 0.092428, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "79a59573-c06e-4a75-b3f8-53d31d0db6c5", "name": "l(r:p1rdt261lv-p1rlv459)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fe4ec5b6-61fb-4b66-9e43-19d81af88966"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c112196-bcbc-41bc-99a9-f3657c335c7a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "33cd8402-3871-4cca-bc3e-debcfdedae9b", "name": "l(r:p1rdt262lv-p1rlv462)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30952601-1479-4770-9b77-9fe3465310b7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9176da24-7eb5-4b0b-99dd-886c3f974798"}}}], "length": {"value": 0.00892698, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c4e43b97-aaab-467e-ad1b-42d7037f358b", "name": "l(r:p1rdt262lv-p1rlv464)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30952601-1479-4770-9b77-9fe3465310b7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "895d0235-3ee6-4f06-9978-9d615d721ebd"}}}], "length": {"value": 0.00892698, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a2576b3e-d1e5-4d50-a45e-1bc57c336d52", "name": "l(r:p1rdt263lv-p1rlv463)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c7501f4-0394-4766-a3c5-b17fda7f3817"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff9d9cca-1878-478d-a190-b58c9098f13e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "ccb77c32-f2aa-4914-bb43-9d5e74ae182b", "name": "l(r:p1rdt270lv-p1rlv474)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d33a03d6-fddc-4e47-8018-cd7d290b30b0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e589527-d388-4364-87d2-2f4af1a14509"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "31239fc0-0cf9-4784-9c31-840b76d2fb9d", "name": "l(r:p1rdt275lv-p1rlv480)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6715c6a-6869-412a-8e59-e5c2eb03c56b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb55ec0b-b6f7-48a7-8dae-dda95fc34499"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "8efe139e-f094-4b94-bbd7-6baf1eb8bb49", "name": "l(r:p1rdt276lv-p1rlv481)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b478b4f8-8d5e-47b0-a56a-8b991dc8d944"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d9e77ad-42c6-4413-96e6-debfed3c442a"}}}], "length": {"value": 0.0246686, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3108cca4-7ce2-4e79-91c3-6164c8569336", "name": "l(r:p1rdt277lv-p1rlv482)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24486e15-ff1e-45b3-aa02-703263f04844"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d4b708f-cc15-4ee3-87e0-4d26fec02f1e"}}}], "length": {"value": 0.0705132, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "924709b2-b4ce-4ebf-aef2-ea121372a161", "name": "l(r:p1rdt278lv-p1rlv483)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8af5824-d5d7-4cba-98b7-d72993909f22"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d059a618-6f09-404b-b1a0-0e7aa0c55c45"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "7ed80917-269f-463c-95a8-142aa98b6c52", "name": "l(r:p1rdm508-p1rlv484)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d6856ee-d113-45ec-99e0-8a915a89a56c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fde62b60-c5f6-44d6-b2f2-211c21b02033"}}}], "length": {"value": 0.0863808, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "dc284c67-9c82-4d92-ba75-22c40eb1286b", "name": "l(r:p1rdm508-p1rdt279lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bf679fe-712f-4db6-9df9-debb29b7ee73"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d6856ee-d113-45ec-99e0-8a915a89a56c"}}}], "length": {"value": 0.0129614, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "060491fd-0236-4f17-87f0-4f05976cbc99", "name": "l(r:p1rdm509-p1rlv485)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c3bf9bd-d12a-47d7-b2e2-3f31f3a0419b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d2c379-7e19-46c4-8c6e-533fa9db7764"}}}], "length": {"value": 0.0942097, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "39ff8538-f941-481e-9b42-22bd4064b712", "name": "l(r:p1rdm509-p1rdt279lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bf679fe-712f-4db6-9df9-debb29b7ee73"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c3bf9bd-d12a-47d7-b2e2-3f31f3a0419b"}}}], "length": {"value": 0.0129614, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9f41c3d1-c279-430b-97c6-bf785447f250", "name": "l(r:p1rdt280lv-p1rlv486)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e4eafd2-0f68-4e2a-a62c-89cb877004d4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a54b2228-9e7d-4e6b-939d-ab2765454522"}}}], "length": {"value": 0.0500266, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "23cca4ef-3f22-42e7-8a89-81df492f80d6", "name": "l(r:p1rdt281lv-p1rlv487)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e01a56d-1bfc-4169-9c3e-1373f9dbeb38"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2d5799-907e-46fd-a389-120aea352775"}}}], "length": {"value": 0.0588997, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9e629ff1-629c-4692-b1b2-89b36d3232b8", "name": "l(r:p1rdt281lv-p1rlv523)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e01a56d-1bfc-4169-9c3e-1373f9dbeb38"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97c38794-7c60-4ff8-b09b-7503c9604409"}}}], "length": {"value": 0.0588997, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f9183960-d27e-48f4-ae96-51a4370514fa", "name": "l(r:p1rdt297lv-p1rlv524)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a8430e1-656f-4fe2-a11b-00adf429d75d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bef074be-aac4-4d82-a832-641729756802"}}}], "length": {"value": 0.0214257, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "67082ac6-4033-43de-8e8e-060172e68525", "name": "l(r:p1rdt297lv-p1rlv526)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a8430e1-656f-4fe2-a11b-00adf429d75d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ab8e220-faf9-4108-80f8-22d2fe326c3d"}}}], "length": {"value": 0.0214257, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "84650700-4442-4d15-838e-e27a38df0870", "name": "l(r:p1rdt298lv-p1rlv525)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33e93250-9c11-4650-9469-412129855857"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a42f8b99-82c6-4c90-81ea-6ccb38eacfab"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "7b449da2-8e87-4ccd-9f7a-16c7fec58d1b", "name": "l(r:p1rdt303lv-p1rlv531)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6353ab92-f66f-47d8-97ac-058cf030ff82"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32a1d9d7-31c7-4def-88d4-e4d41bd21572"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "e0344bf6-1f0f-4397-9dfd-b63e20f8de7e", "name": "l(r:p1rdt304lv-p1rlv532)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a22ac71-bf3a-4016-86ce-fb25f471be5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1362feeb-2e2c-4dd1-9f49-239c952c6120"}}}], "length": {"value": 0.00939374, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a06c0184-9460-4a48-a932-28ad6fdc65df", "name": "l(r:p1rdt304lv-p1rlv533)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a22ac71-bf3a-4016-86ce-fb25f471be5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f79bc5f-375f-4ecd-b828-eb7b137d7cab"}}}], "length": {"value": 0.00939374, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8ba5afa0-cb40-49c4-9876-5b535d676651", "name": "l(r:p1rdt305lv-p1rlv534)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90948977-fe1a-43b3-a8a4-86c080ae4906"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0eb7074c-0745-4089-9329-aa3495f9b460"}}}], "length": {"value": 0.0332146, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "59645c30-0818-4298-96b3-c2e407a38c87", "name": "l(r:p1rdt305lv-p1rlv535)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90948977-fe1a-43b3-a8a4-86c080ae4906"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9cc91945-564c-4ace-bb53-77150b107b41"}}}], "length": {"value": 0.0280899, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f0cacb07-6f88-4b14-83a4-b12237b908e0", "name": "l(r:p1rdt305lv-p1rlv536)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90948977-fe1a-43b3-a8a4-86c080ae4906"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2ea78a8-b9c5-4760-b153-51b45565069e"}}}], "length": {"value": 0.0133525, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cce21752-5938-47bf-94e3-7a78fc6ba8c6", "name": "l(r:p1rdt306lv-p1rlv537)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53eba878-66fa-4d30-8af4-1f583abe5f16"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9f2dfc9e-0b72-4465-b46a-d4e2a7a08f64"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "7f8caa28-d1d5-4677-b1a8-caeaa8438cd5", "name": "l(r:p1rdt335lv-p1rlv588)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8e448ea-e66d-4e16-80c0-8e742d7cac55"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75628d41-a82d-4425-8aa2-9f377c771a4c"}}}], "length": {"value": 0.0252117, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a90371fa-16c1-4478-aa97-5e4dcfe53c31", "name": "l(r:p1rdt335lv-p1rlv589)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8e448ea-e66d-4e16-80c0-8e742d7cac55"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a1c60be-f1a1-48d6-b396-4cca6d8c4e62"}}}], "length": {"value": 0.0305453, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d3cd2429-6120-47a3-8205-e4b92179c8d4", "name": "l(r:p1rdt335lv-p1rlv590)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8e448ea-e66d-4e16-80c0-8e742d7cac55"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81ce208e-7244-418a-9867-b55b95ba0716"}}}], "length": {"value": 0.0192501, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8e534474-8d24-44b0-9a73-58eba8f2be88", "name": "l(r:p1rdt374lv-p1rlv657)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35993388-185f-4d1d-9dcb-16eb7556728f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e58890e-e6ce-4dda-91c0-5ccfdb5c420d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "d9844c82-b169-457d-9bc1-326623b23d77", "name": "l(r:p1rdt376lv-p1rlv660)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d354e81e-b007-4bbe-b1db-50d7afacd0e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15751ee2-6783-472f-ad57-ec978234fec4"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b54298a1-451c-4e04-b0a2-2a3ce8e8d748", "name": "l(r:p1rdt383lv-p1rlv672)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8569c197-174f-46ef-96c2-e0c674d7b046"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb25bf05-ce7f-405a-8c17-fd166748f7d3"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "6b21aab7-acec-4cf4-ad90-947d2d65d55b", "name": "l(r:p1rdt384lv-p1rlv673)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c56b4839-f007-4c9b-93a7-9147399f983f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31d3267c-7020-4660-9a0b-49cd9d94a5d0"}}}], "length": {"value": 0.0823342, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "05b78e9e-8d95-4a3a-8417-ca2d7471d413", "name": "l(r:p1rdt385lv-p1rlv674)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "579c3e97-d1dc-4306-91e6-4cbbed29f882"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "449992d6-a91b-40ea-9792-5166a5f2c849"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "13c5de65-ecbe-46fc-b13c-9b0ae93f362d", "name": "l(r:p1rdt414lv-p1rlv716)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29a78735-964b-4381-bea0-01e5b1b79be9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "93069f0f-fce7-47cd-b7b3-77e861f59573"}}}], "length": {"value": 0.0271185, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7aa72c83-7926-479e-9241-1847dffc0378", "name": "l(r:p1rdt414lv-p1rlv726)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29a78735-964b-4381-bea0-01e5b1b79be9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fdcbc55-681f-4fe5-8142-4945b25f6fef"}}}], "length": {"value": 0.0271185, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f433fa72-7ae0-4813-aec1-c749feeef425", "name": "l(r:p1rdt415lv-p1rlv717)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "789d55de-619d-43cd-b056-ebe1be4c2dea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd8fd159-f747-4ee4-a426-787f4eef4b42"}}}], "length": {"value": 0.0174256, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "40648953-ee06-4844-ac24-ebe40af874cb", "name": "l(r:p1rdt415lv-p1rlv724)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "789d55de-619d-43cd-b056-ebe1be4c2dea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3658479-7369-4bd9-be54-e7768c93a808"}}}], "length": {"value": 0.0174256, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "38efc7d5-3134-4ecb-a601-e7bab591df93", "name": "l(r:p1rdt416lv-p1rlv718)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473f5822-3412-4f3d-836e-f62314efa5b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4a1453b-98a3-4c2d-8ac2-c8b2ab1bfa4f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "42acdb9f-2a40-47c7-9aba-003a71207202", "name": "l(r:p1rdt417lv-p1rlv719)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98bb09be-6506-49e8-8fd8-1a01d6861162"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3153167-8b4c-40e4-abb7-3bdef86950c3"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "a06652f1-5337-439b-bde4-2b0916c1d9af", "name": "l(r:p1rdt418lv-p1rlv720)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e189aaf-7650-49b4-83dd-94a29111aca2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdbc11b7-5abf-4ff8-8d26-53faf4b1f3f5"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "c090ab4d-ac69-4ffb-8288-8e0f550fad74", "name": "l(r:p1rdt419lv-p1rlv721)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d9603d6-5e5e-4cc0-aa86-1bdb80f7e1cf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf12b67c-4df5-4dcb-a2e2-6ae2d0f82e65"}}}], "length": {"value": 0.08840930000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c9d83670-5d7e-4b3e-907b-e3d7877eccf2", "name": "l(r:p1rdt419lv-p1rlv723)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d9603d6-5e5e-4cc0-aa86-1bdb80f7e1cf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7551be44-a4ca-4edb-b823-6495d163201e"}}}], "length": {"value": 0.0583611, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e16c8db8-7dcb-4a01-9073-23a5a1d29c5f", "name": "l(r:p1rdt419lv-p1rlv725)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d9603d6-5e5e-4cc0-aa86-1bdb80f7e1cf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2bcbabc-a7fc-4230-8ec1-b6050af9cf58"}}}], "length": {"value": 0.0308381, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b986d57f-f8a8-4cd7-a6ec-334c76f99e58", "name": "l(r:p1rdt420lv-p1rlv722)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51673983-9230-421b-8501-bf71601b1b13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b7c6c65-e18c-4e79-b419-8894deb0d345"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "270edca9-1e67-412f-8e69-5ffb1e583c7d", "name": "l(r:p1rdt438lv-p1rlv749)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41f19802-32ca-4afc-8418-fe93e3ced1bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80983704-a98f-46dc-a09f-700bd7df1a29"}}}], "length": {"value": 0.0289764, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "538e127f-786f-4818-89c8-a58995828ae0", "name": "l(r:p1rdt438lv-p1rlv756)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41f19802-32ca-4afc-8418-fe93e3ced1bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3c3b0fb-5a5d-439e-a350-b97ba0df41a0"}}}], "length": {"value": 0.0289764, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f81dbe0e-d0d1-46b8-be6d-f9a7a1fc6ef9", "name": "l(r:p1rdt445lv-p1rlv764)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc7e7e51-f849-4bf4-b720-462daeb21932"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e368704b-6c4b-4afb-a577-4b0d7a96dd65"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "2f183098-d22d-473c-bc33-af8fab5902e3", "name": "l(r:p1rdt446lv-p1rlv766)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0727e1f5-f2ca-4e19-9dc3-89e185002e52"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07381934-8e9b-4447-a330-e8af484331f1"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "a5bb6545-64ef-40da-93ad-c0c9ab4b7840", "name": "l(r:p1rdt452lv-p1rlv786)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44f86829-17fc-4e83-b2a5-705454293161"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180adab2-e49b-42e9-9aeb-42be0a7686c5"}}}], "length": {"value": 0.0235153, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "225bdb8e-1f49-441f-8070-f7ca28084a18", "name": "l(r:p1rdm812-p1rlv775)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b4fed6c4-6907-4601-9671-6f83d582dc45"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d00977fb-8d2a-44ca-aa9e-034894d6e280"}}}], "length": {"value": 0.033048600000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "46b762a3-e999-4dbf-9c4f-a1df60636b0d", "name": "l(r:p1rdm812-p1rdt452lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44f86829-17fc-4e83-b2a5-705454293161"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b4fed6c4-6907-4601-9671-6f83d582dc45"}}}], "length": {"value": 0.0176265, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f95d010c-9470-489a-a425-a70c0d0e7256", "name": "l(r:p1rdm814-p1rlv776)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "090024f2-1724-4789-96da-174d1f5e65ec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c5b1f75-47c0-45c3-9ef3-f97a445b242e"}}}], "length": {"value": 0.0217688, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "551a73e5-acdd-437b-a6cc-6aed76529d23", "name": "l(r:p1rdm814-p1rdt453lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d58e1471-844f-46ef-9d9a-43753b1dee25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "090024f2-1724-4789-96da-174d1f5e65ec"}}}], "length": {"value": 0.0176166, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5a95a755-f19a-4c73-a19d-d006865b8bc0", "name": "l(r:p1rdm815-p1rlv819)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ecd0e9ae-cbf4-4435-8a57-ad23e3e037b4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "def7e507-cb62-42f5-8451-b8a742ef4eb2"}}}], "length": {"value": 0.022596800000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cfc97475-b1af-4388-ad2a-4ce25855b710", "name": "l(r:p1rdm815-p1rdt453lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d58e1471-844f-46ef-9d9a-43753b1dee25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ecd0e9ae-cbf4-4435-8a57-ad23e3e037b4"}}}], "length": {"value": 0.0167209, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "316d6767-840f-4299-b109-2097e8d276be", "name": "l(r:p1rdm816-p1rlv777)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2e41779-98fa-453d-b4df-10a5dd61a4b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fb1fca8-7985-4356-a8de-7433fef7a454"}}}], "length": {"value": 0.02155, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f75a9d71-e1a4-402d-bef5-4d848ec31d32", "name": "l(r:p1rdm816-p1rdt454lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b3e7941-9bdd-48f9-a4a5-a553da9bbb57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2e41779-98fa-453d-b4df-10a5dd61a4b5"}}}], "length": {"value": 0.0516187, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d259a7e7-8125-4187-bd47-e94dac2aaab6", "name": "l(r:p1rdm817-p1rlv789)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "87e4ddc3-ccc3-48af-bc35-d7d85f324ee7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9ce2439-fcc7-4965-81ee-f875db83b003"}}}], "length": {"value": 0.0112431, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "61eacf7d-42ae-4dc6-93af-6e874d82465b", "name": "l(r:p1rdm817-p1rdt454lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b3e7941-9bdd-48f9-a4a5-a553da9bbb57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "87e4ddc3-ccc3-48af-bc35-d7d85f324ee7"}}}], "length": {"value": 0.034455, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4b038cb4-9d4c-4388-b73a-07e32d9bdeac", "name": "l(r:p1rdm818-p1rlv800)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf188897-9db5-4ff4-8c5b-5932a8a794cf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3126c61-9602-45cf-8d57-27d26c14ca7e"}}}], "length": {"value": 0.0215285, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ac12c3ae-f77a-49ba-9a39-1cb0876944f4", "name": "l(r:p1rdm818-p1rdt454lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b3e7941-9bdd-48f9-a4a5-a553da9bbb57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf188897-9db5-4ff4-8c5b-5932a8a794cf"}}}], "length": {"value": 0.0352686, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6f93c84f-0710-47ab-a637-536624b07499", "name": "l(r:p1rdm819-p1rlv778)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b757a90a-ade8-486f-90f1-e7c5e13708ba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80d58665-ee8a-4f4e-a906-dc15aa3d8c6f"}}}], "length": {"value": 0.0239474, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8371aa9a-7c91-415a-8947-852337c10539", "name": "l(r:p1rdm819-p1rdt455lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53b40b3c-db5a-4fa0-bedb-f293c6eac473"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b757a90a-ade8-486f-90f1-e7c5e13708ba"}}}], "length": {"value": 0.0220829, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "56703918-b9f0-445c-923f-0b94682269a1", "name": "l(r:p1rdm820-p1rlv787)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea28f170-6bf0-47f7-a089-8375dff2ad4a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0089ee3-0cb4-434c-adc4-c91a8441ef0a"}}}], "length": {"value": 0.0195656, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "36bacdd9-ce23-4cee-9360-b33171a5e6e4", "name": "l(r:p1rdm820-p1rlv811)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea28f170-6bf0-47f7-a089-8375dff2ad4a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "052949b1-9e85-4be7-993c-9e97efda3657"}}}], "length": {"value": 0.0433217, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a9571498-62a2-471e-8799-f99e7d47a967", "name": "l(r:p1rdm820-p1rdt455lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53b40b3c-db5a-4fa0-bedb-f293c6eac473"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea28f170-6bf0-47f7-a089-8375dff2ad4a"}}}], "length": {"value": 0.0172275, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "18797b51-4af7-4275-9dee-63bd226546e9", "name": "l(r:p1rdt456lv-p1rlv837)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6abe982-a205-4607-bacf-08e9d7cb6f54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33492e0f-c907-46c6-a529-503480b642bb"}}}], "length": {"value": 0.0139503, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0a607995-b86f-4370-a9b7-e32ca59422de", "name": "l(r:p1rdm822-p1rlv779)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3cae47a-4077-44e6-9761-fc30d85c3442"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fbc761bf-480c-465c-9479-279832c50bc2"}}}], "length": {"value": 0.0269896, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f52fa39d-c9fd-4e85-85bc-c2a8df92edbc", "name": "l(r:p1rdm822-p1rdt456lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6abe982-a205-4607-bacf-08e9d7cb6f54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3cae47a-4077-44e6-9761-fc30d85c3442"}}}], "length": {"value": 0.0541811, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "656582d9-cadf-4851-9af9-1fedf3643435", "name": "l(r:p1rdm823-p1rlv831)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84ca6719-0bbc-440a-b0eb-23b8f32dcf47"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4b6c4e-78d0-4c8e-907c-619f1e43c149"}}}], "length": {"value": 0.0211142, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c7c588e1-b801-4e20-968d-74dbf8bb0382", "name": "l(r:p1rdm823-p1rdt456lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6abe982-a205-4607-bacf-08e9d7cb6f54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84ca6719-0bbc-440a-b0eb-23b8f32dcf47"}}}], "length": {"value": 0.0102805, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "836ed46a-5f6d-4870-8499-1278a9ec7351", "name": "l(r:p1rdt457lv-p1rlv780)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "866745cc-62c9-429f-8389-fcc5a1710f17"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20dcf67f-f04f-498a-830d-557ba7b4d867"}}}], "length": {"value": 0.0223005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8a6c23db-3a7c-425d-b48b-633fdc42fc2c", "name": "l(r:p1rdm826-p1rlv783)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf7e29df-0880-4c8c-aa5c-c43f24dd820e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d1a96d5-f971-4116-9642-769ef5b97e7c"}}}], "length": {"value": 0.0163209, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7ed37ca1-5449-46b0-8458-47d0591766d5", "name": "l(r:p1rdm826-p1rlv795)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf7e29df-0880-4c8c-aa5c-c43f24dd820e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb137176-0642-4d87-ae40-1b7b0e1cb214"}}}], "length": {"value": 0.0159024, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1d6bc55d-4607-481e-9105-0b616cb72843", "name": "l(r:p1rdm827-p1rlv791)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8fafab6a-7d1c-4b87-94b3-5bc4d09ff95d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fe9bb3f-e3c1-4b59-b39f-f62271a55bdd"}}}], "length": {"value": 0.0242315, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5bb2309e-ef7a-4950-be3f-4ea437e50a10", "name": "l(r:p1rdm826-p1rdm827)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf7e29df-0880-4c8c-aa5c-c43f24dd820e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8fafab6a-7d1c-4b87-94b3-5bc4d09ff95d"}}}], "length": {"value": 0.0328507, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "dad113c6-9e9e-4700-9435-c7ff0a205da7", "name": "l(r:p1rdm826-p1rdt457lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "866745cc-62c9-429f-8389-fcc5a1710f17"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf7e29df-0880-4c8c-aa5c-c43f24dd820e"}}}], "length": {"value": 0.0167732, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d1330071-2d41-4078-9307-b70a676ad0f8", "name": "l(r:p1rdm829-p1rlv801)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc2d45e2-caa5-4f7d-976e-ccb045c30559"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ecc45b2-1fbe-4a31-995f-e2f8fffe61a7"}}}], "length": {"value": 0.0173132, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6d008500-ace5-48f8-b33f-b4d50e08262d", "name": "l(r:p1rdm829-p1rlv817)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc2d45e2-caa5-4f7d-976e-ccb045c30559"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11064c6f-3b7a-43b5-96ca-7ef96be3815e"}}}], "length": {"value": 0.0169258, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bbc1606e-a1f3-4038-adcb-7d343a8b0784", "name": "l(r:p1rdm829-p1rdt457lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "866745cc-62c9-429f-8389-fcc5a1710f17"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc2d45e2-caa5-4f7d-976e-ccb045c30559"}}}], "length": {"value": 0.0335366, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9afa8eb4-0776-4773-bde9-230acba79717", "name": "l(r:p1rdm831-p1rlv781)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c668ab72-249e-4463-a3b4-863c7fe826c1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98c5ba15-a339-478a-a79f-9298fab16a54"}}}], "length": {"value": 0.0157907, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ec1f3dfe-9be2-448d-895d-a61b55020888", "name": "l(r:p1rdm831-p1rdt458lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67e071ab-e3dc-4779-9e81-585547cd22ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c668ab72-249e-4463-a3b4-863c7fe826c1"}}}], "length": {"value": 0.0148102, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "737caffb-1251-4b71-ad12-6e6bd5bcc4ab", "name": "l(r:p1rdm832-p1rlv843)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "92f03cbf-2585-4e0e-ab0a-cda0b267b34d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3bc013f-c78d-4a3c-b27f-826c3025de0e"}}}], "length": {"value": 0.0182301, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "be49c7ea-d626-4897-b7c0-0ea973232fd8", "name": "l(r:p1rdm832-p1rdt458lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67e071ab-e3dc-4779-9e81-585547cd22ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "92f03cbf-2585-4e0e-ab0a-cda0b267b34d"}}}], "length": {"value": 0.0184885, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5925af09-96ab-46bf-abc1-3ec6d4d2624c", "name": "l(r:p1rdt459lv-p1rlv782)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9eb57d99-ae80-43da-b0cb-b26bdd583e1a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78a4f54a-017a-41b0-85c8-b3e408c21c08"}}}], "length": {"value": 0.0258607, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8d191be9-fb1c-439a-ac8b-e150326846f5", "name": "l(r:p1rdt460lv-p1rlv784)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028bc055-0ee6-4729-8cd2-15bd7153f975"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2823b5b9-bcc3-4b30-9874-89dc33ec80d2"}}}], "length": {"value": 0.0153083, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "01c60984-030f-4370-8898-c1ca4a48a722", "name": "l(r:p1rdt460lv-p1rlv797)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028bc055-0ee6-4729-8cd2-15bd7153f975"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b1c34f1-2613-46aa-9a9f-686ee518e559"}}}], "length": {"value": 0.0114124, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "983e5468-f132-471e-8de4-a2d98111b7bd", "name": "l(r:p1rdm837-p1rlv806)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "790d0b88-fed2-4c90-bfdf-44d3c31d3d8d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d9f269a-e476-4b82-a258-479d812d008d"}}}], "length": {"value": 0.0126883, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2cfbe94b-e247-4450-bba8-f81b935875b7", "name": "l(r:p1rdm835-p1rlv796)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0e1d710-2ab1-43ca-a7c1-8f05a6c0b753"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59662cef-c126-4188-ad86-844f6cabaf34"}}}], "length": {"value": 0.0156616, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4fe3046b-4238-4a56-b548-8a1681e4538b", "name": "l(r:p1rdm835-p1rdm837)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "790d0b88-fed2-4c90-bfdf-44d3c31d3d8d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0e1d710-2ab1-43ca-a7c1-8f05a6c0b753"}}}], "length": {"value": 0.0179452, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2f533d69-4418-47da-be78-5ac5b4c94399", "name": "l(r:p1rdm837-p1rdt460lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028bc055-0ee6-4729-8cd2-15bd7153f975"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "790d0b88-fed2-4c90-bfdf-44d3c31d3d8d"}}}], "length": {"value": 0.0703462, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e073f275-9a06-4a39-b591-4624acf201a2", "name": "l(r:p1rdm838-p1rlv810)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83fdcccd-6a26-4311-aad3-da67dac5af42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb4a881f-684d-48e4-a6f0-5832f73d140a"}}}], "length": {"value": 0.0133783, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a23cc94c-4329-4e58-908f-3f124f3c4745", "name": "l(r:p1rdm839-p1rlv822)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "344c24ef-9d54-4c1a-9aa4-852a76ddbec7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7ce197c-cee4-40df-b1d7-be13f1be8bb1"}}}], "length": {"value": 0.026775, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9052c72c-1afa-4aae-ab91-a44fd081b6e6", "name": "l(r:p1rdm840-p1rlv839)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0649432-ddb6-4648-8efe-27ee1fd959e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48e97be9-1f80-457f-a56e-79f54458c620"}}}], "length": {"value": 0.0161282, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7b128ad7-4208-4cdc-8fe3-a452dcc56bf8", "name": "l(r:p1rdm839-p1rdm840)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "344c24ef-9d54-4c1a-9aa4-852a76ddbec7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0649432-ddb6-4648-8efe-27ee1fd959e4"}}}], "length": {"value": 0.0193155, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6751f34e-86f1-4742-bcbf-9599466eaa30", "name": "l(r:p1rdm838-p1rdm839)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83fdcccd-6a26-4311-aad3-da67dac5af42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "344c24ef-9d54-4c1a-9aa4-852a76ddbec7"}}}], "length": {"value": 0.0193228, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a3012458-a638-42aa-9386-6e16993d49e7", "name": "l(r:p1rdm838-p1rdt460lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028bc055-0ee6-4729-8cd2-15bd7153f975"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83fdcccd-6a26-4311-aad3-da67dac5af42"}}}], "length": {"value": 0.0193155, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0ea070ec-3b8d-4c37-8cf9-11c6930961e5", "name": "l(r:p1rdm841-p1rlv785)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "505b390e-ffd3-482a-8ae9-b8d6bd8be94f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa98d6c6-7086-4033-a9af-c0a33e802942"}}}], "length": {"value": 0.0383319, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "64541dee-7746-4e3a-93ea-f335ec5f5254", "name": "l(r:p1rdm841-p1rdt461lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd9a4931-435b-4b48-907c-024c0b8a4816"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "505b390e-ffd3-482a-8ae9-b8d6bd8be94f"}}}], "length": {"value": 0.0196806, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3ee4a741-0ae5-41a1-9e6f-04e31c8cbce7", "name": "l(r:p1rdm842-p1rlv793)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "172dd9d0-eab4-4481-9edd-f868e6ed87d9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e8c4bc9-0688-43e6-93a8-9664c9b618b7"}}}], "length": {"value": 0.0393311, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e73d98ae-6229-4f85-99ef-3e20d6469868", "name": "l(r:p1rdm842-p1rdt461lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd9a4931-435b-4b48-907c-024c0b8a4816"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "172dd9d0-eab4-4481-9edd-f868e6ed87d9"}}}], "length": {"value": 0.0393612, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "92814b38-b3fd-497d-bd3d-8166ce56fb13", "name": "l(r:p1rdt462lv-p1rlv790)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d96f458-607c-4820-90b1-6fb2625ace7f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf42fa7f-370e-400e-8f6d-76eb8c70ecb9"}}}], "length": {"value": 0.0135001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c513a390-dacc-41d8-84e2-d8c1c494e6af", "name": "l(r:p1rdm843-p1rlv788)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ac64728-e64c-4241-8a3f-b884f11c6393"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9f470d9-6ead-4413-ad8a-7ccc69ae9237"}}}], "length": {"value": 0.0145732, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "78bb8d17-03cd-4ee9-91a7-b347bd572978", "name": "l(r:p1rdm846-p1rlv864)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2086cded-e13c-4683-824e-9e15f99e12e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e2a8871-7bc4-497f-9954-38db92cb3eba"}}}], "length": {"value": 0.0186895, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "13f88096-53de-4f16-99b0-bb6660af5596", "name": "l(r:p1rdm843-p1rdm846)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ac64728-e64c-4241-8a3f-b884f11c6393"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2086cded-e13c-4683-824e-9e15f99e12e8"}}}], "length": {"value": 0.0176441, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c52a3921-ae5b-4628-bddd-3ff0bd8a700c", "name": "l(r:p1rdm843-p1rdt462lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d96f458-607c-4820-90b1-6fb2625ace7f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ac64728-e64c-4241-8a3f-b884f11c6393"}}}], "length": {"value": 0.0186824, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cc7add68-0788-446c-b784-1994d85a83eb", "name": "l(r:p1rdm845-p1rlv840)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b4620a0-c781-422e-8cc7-3ceed9a0c8dc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "024961c3-25f4-4a15-a52a-7f88dc652766"}}}], "length": {"value": 0.046968, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "65243760-4f2f-4d5d-8d33-e47ffe9a3b4c", "name": "l(r:p1rdm845-p1rlv865)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b4620a0-c781-422e-8cc7-3ceed9a0c8dc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abdfa5db-c398-4638-805d-6d55597e1921"}}}], "length": {"value": 0.0131897, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b331290f-e764-4cff-b625-e8475759c1a7", "name": "l(r:p1rdm845-p1rlv867)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b4620a0-c781-422e-8cc7-3ceed9a0c8dc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a7cca48-fd4b-4630-a479-55f2b6ada03b"}}}], "length": {"value": 0.0296877, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "bc9614b3-e07c-4eab-b885-d06bc6380a70", "name": "l(r:p1rdm845-p1rdt462lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d96f458-607c-4820-90b1-6fb2625ace7f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b4620a0-c781-422e-8cc7-3ceed9a0c8dc"}}}], "length": {"value": 0.0137562, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "25952ee5-154e-4e8f-9fa0-73f87e781bd5", "name": "l(r:p1rdt463lv-p1rlv792)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f660c35e-85f8-4f0e-b03b-806006c76c67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f806232e-0a52-46d5-80f7-7ea3a914137a"}}}], "length": {"value": 0.0161855, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b48f1192-2fba-4630-93a6-3be9d6b52672", "name": "l(r:p1rdm850-p1rlv860)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c397a5a5-21bc-4f4d-9f24-7af1219b70e7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bada1117-5605-4aec-9314-8013ed243e3c"}}}], "length": {"value": 0.0408644, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d33c5ecb-5a3f-4998-a939-ade4ab891a57", "name": "l(r:p1rdm850-p1rdt463lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f660c35e-85f8-4f0e-b03b-806006c76c67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c397a5a5-21bc-4f4d-9f24-7af1219b70e7"}}}], "length": {"value": 0.013479, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2e6bf64f-c3c4-4d85-9090-27d3db1d86e7", "name": "l(r:p1rdt464lv-p1rlv794)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "749e07aa-74ce-40f2-a352-9c55f9914377"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eecc456-41af-4242-ab30-d8ca45d55a2c"}}}], "length": {"value": 0.0144527, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c1905497-9abe-4faa-bd82-2075dd0d3940", "name": "l(r:p1rdm852-p1rlv825)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17b42dae-f856-4945-ba7a-9d3f47e049fe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d209dff6-7a24-41ef-947a-8c6f79c2d65c"}}}], "length": {"value": 0.0239195, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "49992f45-5856-436a-a479-f60b021e18fc", "name": "l(r:p1rdm852-p1rdt464lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "749e07aa-74ce-40f2-a352-9c55f9914377"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17b42dae-f856-4945-ba7a-9d3f47e049fe"}}}], "length": {"value": 0.0188143, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ee5d8865-3fd3-4795-a0b8-dfd4e9a93cac", "name": "l(r:p1rdm853-p1rlv829)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08c93f8a-9600-4ffd-8e18-576d433ce777"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e3a1bd0-69fe-42bb-993d-2094ecc658ce"}}}], "length": {"value": 0.016328, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bccbc133-6fa8-4fa3-a2bc-802cdda86910", "name": "l(r:p1rdm853-p1rdt464lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "749e07aa-74ce-40f2-a352-9c55f9914377"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08c93f8a-9600-4ffd-8e18-576d433ce777"}}}], "length": {"value": 0.0188277, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c3fc0daf-894b-469f-9e4e-90bd63d9f129", "name": "l(r:p1rdm855-p1rlv809)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5ad091a-3b6a-4069-a642-104c28a94dc4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e0f8ee8-795f-4bea-bf7a-e2c477eefb89"}}}], "length": {"value": 0.0141744, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1520e88a-1c47-4c6d-8a0d-2904cb8c3a88", "name": "l(r:p1rdm855-p1rdt465lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "433b0872-49c4-452c-941c-8083a72840ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5ad091a-3b6a-4069-a642-104c28a94dc4"}}}], "length": {"value": 0.0498634, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d406b735-8fac-47c1-b56e-db92b40af1d0", "name": "l(r:p1rdm856-p1rlv862)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eaf112db-b9dc-4d90-b030-3e26188aaf2b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5e2c3a2-32c0-4bb9-9802-265cec784974"}}}], "length": {"value": 0.0132627, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c94f9ba6-f842-44b4-937f-ca55007e9b89", "name": "l(r:p1rdm854-p1rlv798)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb73d9f2-aefb-430c-babd-ac02422eb212"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c30005d7-7e42-4a08-8935-0c7227fba4a6"}}}], "length": {"value": 0.0514932, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "fe2fe4cc-1ca1-49ea-ace0-0dbe19fab608", "name": "l(r:p1rdm854-p1rdm856)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eaf112db-b9dc-4d90-b030-3e26188aaf2b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb73d9f2-aefb-430c-babd-ac02422eb212"}}}], "length": {"value": 0.0253738, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2708a02c-5630-4ed5-bb7d-7e48b577f60a", "name": "l(r:p1rdm856-p1rdt465lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "433b0872-49c4-452c-941c-8083a72840ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eaf112db-b9dc-4d90-b030-3e26188aaf2b"}}}], "length": {"value": 0.0330337, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2d1d33df-5e6c-431b-a65b-5d1417397b37", "name": "l(r:p1rdm857-p1rlv799)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c274aa99-a566-4915-83af-7115bec586b1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f706d9d-0cb1-453b-9ca5-377f7d766099"}}}], "length": {"value": 0.022264, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "10265fad-8f7c-43c0-865e-ed7430319af3", "name": "l(r:p1rdm857-p1rdt466lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f422478c-0d77-48c8-87fb-e883d945f8a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c274aa99-a566-4915-83af-7115bec586b1"}}}], "length": {"value": 0.0280491, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "bc234c0a-aedd-48db-91de-21fa0c5454f3", "name": "l(r:p1rdm858-p1rlv815)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "caa7d639-522c-4fd6-8b74-73a337bd67d2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a134556-828b-4e0c-8773-2f207802e33a"}}}], "length": {"value": 0.011569, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9545bc08-0145-463c-b762-538f3e078558", "name": "l(r:p1rdm858-p1rdt466lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f422478c-0d77-48c8-87fb-e883d945f8a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "caa7d639-522c-4fd6-8b74-73a337bd67d2"}}}], "length": {"value": 0.0785759, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9953a9df-5156-41c7-bec3-13c3ee28db49", "name": "l(r:p1rdt467lv-p1rlv802)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23ed76af-dcb2-4333-ae4c-d7439a37cf87"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2436086-d5c4-4b70-a402-e7d1b6f5b77e"}}}], "length": {"value": 0.023669900000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2548bca4-fda9-4a73-910a-19b98378697f", "name": "l(r:p1rdm861-p1rlv823)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a4bf0e0-92f0-4cd9-afc5-65d9ed242271"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81802469-7320-47e9-b826-fbb33bd371ab"}}}], "length": {"value": 0.0345947, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8f4cba40-f07f-44e4-bac9-1440e21e8bee", "name": "l(r:p1rdm860-p1rlv803)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bfca289-c04c-45d9-8104-40089fc1737e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "018c978c-5673-4090-9792-b75ee161f6d2"}}}], "length": {"value": 0.0184835, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6bde25a7-76c5-4800-9e4b-43f9aeacabc8", "name": "l(r:p1rdm860-p1rdm861)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a4bf0e0-92f0-4cd9-afc5-65d9ed242271"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bfca289-c04c-45d9-8104-40089fc1737e"}}}], "length": {"value": 0.0148709, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fa82ac3a-35f9-4698-aead-a39ffd2d44cf", "name": "l(r:p1rdm861-p1rdt468lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b368fb8f-7f4d-4558-b6b2-2e1db4087727"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a4bf0e0-92f0-4cd9-afc5-65d9ed242271"}}}], "length": {"value": 0.014361200000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "835c6b61-9f3f-4249-9990-71565e51e175", "name": "l(r:p1rdm862-p1rlv833)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1daf402d-faec-4230-b4ab-1efa6283ac0f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eb57fc4-636d-4923-9f4a-d308b062599f"}}}], "length": {"value": 0.019033400000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1b317b7f-25ad-49f7-aeea-76bf76f69a9a", "name": "l(r:p1rdm862-p1rdt468lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b368fb8f-7f4d-4558-b6b2-2e1db4087727"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1daf402d-faec-4230-b4ab-1efa6283ac0f"}}}], "length": {"value": 0.0659529, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "40e9f9b9-d755-457c-ae45-10112f652013", "name": "l(r:p1rdt469lv-p1rlv805)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d12ab15f-746d-462b-b395-e2b330ba1226"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0475b34e-14ab-48e4-9df7-7444de1cde7d"}}}], "length": {"value": 0.0142913, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7eb1f89d-2f21-4647-98bc-44051405b731", "name": "l(r:p1rdt470lv-p1rlv858)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15ab2647-a801-4cb5-a1f7-528118ff5dea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab33ce2f-3131-4cfb-8df2-329fb4aa76b7"}}}], "length": {"value": 0.0299737, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8ee7e39b-981a-4a50-a8aa-4beac6fb4788", "name": "l(r:p1rdm864-p1rlv807)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d861761c-3fe7-437d-917d-8beb24318a42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa259be8-8a61-461a-9e58-d4aaf1ce82db"}}}], "length": {"value": 0.0310907, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "bcb37d15-54f7-4625-abab-989665dada61", "name": "l(r:p1rdm864-p1rdt470lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15ab2647-a801-4cb5-a1f7-528118ff5dea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d861761c-3fe7-437d-917d-8beb24318a42"}}}], "length": {"value": 0.0179311, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5baa0f0e-f822-49b5-9ad4-b3251d29ee4a", "name": "l(r:p1rdt471lv-p1rlv826)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40d98c0b-4c66-4581-9553-f5f57c4b27b9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06746d4d-3db8-45b1-888e-d3d9e405ccaf"}}}], "length": {"value": 0.0163584, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fdac3d14-fa24-42f8-9bae-84816b5ad58b", "name": "l(r:p1rdm866-p1rlv808)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "467753c6-5c1f-4a9d-8a7d-21419b25565f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dcb86a4-e6d7-48b4-b5c2-904635de271b"}}}], "length": {"value": 0.0174196, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0e801fac-7a5f-4816-949a-70e0e49ec4fc", "name": "l(r:p1rdm866-p1rdt471lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40d98c0b-4c66-4581-9553-f5f57c4b27b9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "467753c6-5c1f-4a9d-8a7d-21419b25565f"}}}], "length": {"value": 0.0199112, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "050d509c-ca7e-4b08-84a4-bc625adcd272", "name": "l(r:p1rdt472lv-p1rlv866)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f026a1d3-23b0-4454-a09b-e1c08cc06392"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b4834dc-6bdf-4102-bc13-589392b2e75a"}}}], "length": {"value": 0.0127516, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ed35c9fb-26b6-408a-a136-c0d4237551af", "name": "l(r:p1rdm868-p1rlv812)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0ca3ea5-ad01-4e52-883a-c07805f613dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26fea867-af5f-4213-b9c3-487975d1285e"}}}], "length": {"value": 0.00862481, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "54aae335-7d0d-4c7e-af07-9024a6d3f6cd", "name": "l(r:p1rdm868-p1rdt472lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f026a1d3-23b0-4454-a09b-e1c08cc06392"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0ca3ea5-ad01-4e52-883a-c07805f613dd"}}}], "length": {"value": 0.0108197, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1a29acaa-ce20-4436-aec1-4fbd44cde777", "name": "l(r:p1rdm870-p1rlv813)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aa0c31f-baa3-4db8-87d9-0a4ab9a83a8a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10d44b60-55c0-4d78-abbb-52c8cd67134b"}}}], "length": {"value": 0.0316898, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e094be1d-90f2-49a3-a4e2-2154277e7184", "name": "l(r:p1rdm870-p1rdt473lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f435ec5-8c03-45ba-925b-83bad9501047"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aa0c31f-baa3-4db8-87d9-0a4ab9a83a8a"}}}], "length": {"value": 0.0167209, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c55075c5-7299-40ca-aa59-5710f1dc5ae2", "name": "l(r:p1rdm871-p1rlv818)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67c560cc-d815-41d4-8087-b66beaacb404"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd8c54fd-14d4-46fa-8bef-59c1097d5026"}}}], "length": {"value": 0.0247114, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a4a2af30-2b5e-4c51-8842-5f18a7462994", "name": "l(r:p1rdm871-p1rdt473lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f435ec5-8c03-45ba-925b-83bad9501047"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67c560cc-d815-41d4-8087-b66beaacb404"}}}], "length": {"value": 0.016721, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "33025ab1-b5f9-4e7b-8bc9-e05b23ba208d", "name": "l(r:p1rdt474lv-p1rlv814)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "839858f4-3b18-40c3-86f3-e27225e6aba4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b8065f3-8286-4f99-aa56-b9b631a2f838"}}}], "length": {"value": 0.012214300000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4661a900-6153-47f8-ac49-284e1c025724", "name": "l(r:p1rdt474lv-p1rlv827)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "839858f4-3b18-40c3-86f3-e27225e6aba4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c89db91-40fe-4de6-973e-5d8c23e35080"}}}], "length": {"value": 0.0251297, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "97a99a43-b4cf-4a53-8be1-b6f8c9c9d923", "name": "l(r:p1rdm874-p1rlv816)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ec705b7-fdaa-4eca-96eb-5dabb8256c78"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d6de7c2-fd2c-4071-8e90-1513f521cf87"}}}], "length": {"value": 0.00993642, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5d33e469-fbbc-4dbe-8cc0-037dc6f1521d", "name": "l(r:p1rdm874-p1rdt475lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1be3e20a-3890-4e9c-b568-ca99421e751c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ec705b7-fdaa-4eca-96eb-5dabb8256c78"}}}], "length": {"value": 0.0196806, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3e499df6-5b54-4188-87f6-b114b7ddc9d2", "name": "l(r:p1rdm875-p1rlv834)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c17541ac-d30f-4f0a-9660-f9b9f7012b3a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d437c83c-cbd1-41bf-b455-21123e82d59f"}}}], "length": {"value": 0.0324009, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e4649022-4878-4685-9bfd-6c03c7634b0d", "name": "l(r:p1rdm875-p1rdt475lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1be3e20a-3890-4e9c-b568-ca99421e751c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c17541ac-d30f-4f0a-9660-f9b9f7012b3a"}}}], "length": {"value": 0.0393612, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "aea17153-d289-4fb6-bf02-3c99f43ad7b3", "name": "l(r:p1rdt476lv-p1rlv836)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ffde8c6-9dba-4f13-bda5-a0edf17c736d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12556ab7-c50a-4624-9d84-b85585822245"}}}], "length": {"value": 0.0139229, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d23cc706-758d-4c5f-bfe0-c5d897e7a67d", "name": "l(r:p1rdm878-p1rlv842)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f83e2ade-1911-4124-9fbe-6f482d68eba9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8f304a4-6e39-4288-9b9b-e41bb37c6019"}}}], "length": {"value": 0.015212700000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "34d2a6b1-8462-4bde-bf65-082e9aa25dd8", "name": "l(r:p1rdm878-p1rdt476lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ffde8c6-9dba-4f13-bda5-a0edf17c736d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f83e2ade-1911-4124-9fbe-6f482d68eba9"}}}], "length": {"value": 0.0183516, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1906dc6c-7625-4d68-9c53-d3ec88d367b4", "name": "l(r:p1rdm879-p1rlv868)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "260b560c-e6d6-4069-b67f-067c468a7768"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "009758e3-b4ae-427a-9c30-f2a8bb2953d1"}}}], "length": {"value": 0.0303242, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4573dcbc-735f-4cc2-bedf-3e3bf2bb2e6d", "name": "l(r:p1rdm876-p1rlv820)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5331a4f-ab91-4fea-a301-11b7afb6c8ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41e1e576-4cc9-4fea-9d87-d436f000a675"}}}], "length": {"value": 0.0226825, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "dad50477-3454-429d-889f-7802e2fe03db", "name": "l(r:p1rdm876-p1rdm879)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "260b560c-e6d6-4069-b67f-067c468a7768"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5331a4f-ab91-4fea-a301-11b7afb6c8ca"}}}], "length": {"value": 0.018351400000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2b2c06e9-faf7-4a27-b89e-2fd4aff2d4f9", "name": "l(r:p1rdm879-p1rdt476lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ffde8c6-9dba-4f13-bda5-a0edf17c736d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "260b560c-e6d6-4069-b67f-067c468a7768"}}}], "length": {"value": 0.018351400000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f1cee872-ffd6-4181-91ca-28bc5644d2e5", "name": "l(r:p1rdt477lv-p1rlv821)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7c94703b-303a-4713-95c0-b2933fe0e70b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5578d8b4-7c1e-444f-8d27-8c9bf733f420"}}}], "length": {"value": 0.012208200000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "dae4ec0f-7656-4005-b37e-4f869ca62aaa", "name": "l(r:p1rdt477lv-p1rlv828)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7c94703b-303a-4713-95c0-b2933fe0e70b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08c3f5ef-c2d5-4ce2-8fc7-b665d8cbbab6"}}}], "length": {"value": 0.0188029, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e31a013a-6276-486a-95ad-8156f93c04e3", "name": "l(r:p1rdt478lv-p1rlv824)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c93c776d-68b8-4e4e-8e5e-d5e34003473c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20ce76b6-9305-4525-b77e-b7300edc2c81"}}}], "length": {"value": 0.0283636, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "66a1a477-9441-4daa-8e19-9ae195db32ba", "name": "l(r:p1rdt479lv-p1rlv832)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8037b713-d948-43c9-8370-fb8fcf6dec15"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10373c0d-6a3c-4160-a174-22de447d4c38"}}}], "length": {"value": 0.012648, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1bba640c-d184-4cd8-8d9f-8d718e5d85d0", "name": "l(r:p1rdt480lv-p1rlv835)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "423402f9-4160-481b-9951-a955f8314075"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bc35476-5839-4095-bea5-36e32450b890"}}}], "length": {"value": 0.0370417, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "12477693-3b27-4bb8-9818-8febe1402966", "name": "l(r:p1rdt481lv-p1rlv841)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1761b021-00e0-4880-9f05-62cf67aef0e6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eb6c1b4-f09a-44a5-a13f-64051183736d"}}}], "length": {"value": 0.0229879, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4b8f9b84-3375-44e3-996f-8f2b9b7fc95b", "name": "l(r:p1rdt482lv-p1rlv844)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c445ea76-5167-4d55-b0c5-cc53dadc5b5e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26294827-db76-40b6-b652-1e41efdf15dc"}}}], "length": {"value": 0.0225992, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a38cf1c8-e554-4ff7-9189-f9f0861fb6f3", "name": "l(r:p1rdm887-p1rlv846)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3929a951-8b8b-42e9-a839-40c29e680108"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "145d3757-ca09-45ca-9199-465b6b43fbb7"}}}], "length": {"value": 0.025727, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "72d6b0dd-0037-4a7f-b678-dd0aa4abb16a", "name": "l(r:p1rdm887-p1rdt482lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c445ea76-5167-4d55-b0c5-cc53dadc5b5e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3929a951-8b8b-42e9-a839-40c29e680108"}}}], "length": {"value": 0.0374944, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b6f8b4d2-1bc0-4679-9713-9bcd313232ad", "name": "l(r:p1rdm888-p1rlv848)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0318cdac-5c7b-4711-a0d7-9c7e104c8281"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e484d77-29ac-4903-afa3-f677283db883"}}}], "length": {"value": 0.0169569, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "50bbf606-cb43-4516-91a8-dadf8c13416a", "name": "l(r:p1rdm888-p1rdt482lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c445ea76-5167-4d55-b0c5-cc53dadc5b5e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0318cdac-5c7b-4711-a0d7-9c7e104c8281"}}}], "length": {"value": 0.0374944, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "de9da477-e2e9-4af6-be08-69a14dcb5a12", "name": "l(r:p1rdt483lv-p1rlv845)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "475b6a50-9814-4016-bb88-be5b1b2ac31d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b053d449-b15b-4292-9a73-9b7d104a8e38"}}}], "length": {"value": 0.016859600000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6e28be69-05a4-42ac-ad11-d34b22f52d5d", "name": "l(r:p1rdt483lv-p1rlv851)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "475b6a50-9814-4016-bb88-be5b1b2ac31d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48b5535c-f00d-4b48-a23a-87f3f212302f"}}}], "length": {"value": 0.0190238, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bd6f5a20-0cfc-458e-83ac-da3256bcb423", "name": "l(r:p1rdt483lv-p1rlv859)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "475b6a50-9814-4016-bb88-be5b1b2ac31d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ea0f4f5-2024-45a8-9f8f-f5963e7d2727"}}}], "length": {"value": 0.0273815, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "16ca1d8c-f178-4b98-9b82-1048582e46dc", "name": "l(r:p1rdm892-p1rlv855)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "18ea7daf-9665-4d68-b255-12d41bdb2396"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10611e08-75e2-4422-ac0f-cfb98c7eae4b"}}}], "length": {"value": 0.0184228, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8982efe3-fe34-4f46-8ba6-0da7942cd0e9", "name": "l(r:p1rdm890-p1rlv849)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0398ef91-eeb8-4d34-b05e-e88adabdd487"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a95877ca-8600-4e95-82ac-c51cb82acf16"}}}], "length": {"value": 0.0307799, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "336123d1-06d4-42bc-91ca-b2faf7f420c1", "name": "l(r:p1rdm890-p1rdm892)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "18ea7daf-9665-4d68-b255-12d41bdb2396"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0398ef91-eeb8-4d34-b05e-e88adabdd487"}}}], "length": {"value": 0.0712019, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e18fc9dc-b6c4-48fb-a18a-e11d951be718", "name": "l(r:p1rdm892-p1rdt483lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "475b6a50-9814-4016-bb88-be5b1b2ac31d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "18ea7daf-9665-4d68-b255-12d41bdb2396"}}}], "length": {"value": 0.016043, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0fe81417-b25b-4f18-8740-612e6afbda1c", "name": "l(r:p1rdt484lv-p1rlv847)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f396745a-5edb-4ab8-8bc7-2b181719cbf4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "283142ff-4884-4adc-9d4c-f8615505415a"}}}], "length": {"value": 0.0214364, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cd25035f-8cc9-4351-99d1-da90e1465103", "name": "l(r:p1rdm895-p1rlv856)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e96e4c25-4664-45ae-b77c-9e0047f65c8b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25f84b28-695b-4d32-b96c-914226444b9f"}}}], "length": {"value": 0.0167306, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e2643c5e-63e6-45b4-9a5c-87df5a4bba08", "name": "l(r:p1rdm895-p1rdt484lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f396745a-5edb-4ab8-8bc7-2b181719cbf4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e96e4c25-4664-45ae-b77c-9e0047f65c8b"}}}], "length": {"value": 0.0181803, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e4e3f62f-6a52-4772-8105-017c43ea8625", "name": "l(r:p1rdm896-p1rlv850)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60637f4b-8538-4b21-988c-1b13adecc647"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d49057-9c70-4489-95bb-36b5b574e13d"}}}], "length": {"value": 0.0266685, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c65cddfc-7654-418e-bc98-41fa27f8c007", "name": "l(r:p1rdm896-p1rdt485lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da38ec0a-f37d-4a5c-8da0-93410a8fb475"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60637f4b-8538-4b21-988c-1b13adecc647"}}}], "length": {"value": 0.016779100000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d1a11481-6f65-4363-9e68-bb0fda7a5dc9", "name": "l(r:p1rdm897-p1rlv853)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3464daa0-06b2-4d5d-9901-bb34050fe619"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "365eff25-8ccb-448b-894f-ad662fe6d684"}}}], "length": {"value": 0.0210885, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a013e7d5-c8e8-4c90-8afd-836bd7c9313b", "name": "l(r:p1rdm897-p1rdt485lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da38ec0a-f37d-4a5c-8da0-93410a8fb475"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3464daa0-06b2-4d5d-9901-bb34050fe619"}}}], "length": {"value": 0.014660500000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1fd6bbe3-8659-48dd-aa1f-9e5788d134f1", "name": "l(r:p1rdm898-p1rlv852)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d9b6dee-73e1-43ab-ac9b-7d20fb77b6df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32142941-c546-4356-ba80-123b9128b5de"}}}], "length": {"value": 0.0198361, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c93ddd5b-ec87-4033-ba5f-d8293329e37f", "name": "l(r:p1rdm898-p1rdt486lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5401d366-a5a2-4753-82b7-ce4fa08a1227"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d9b6dee-73e1-43ab-ac9b-7d20fb77b6df"}}}], "length": {"value": 0.03692270000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0dc1cf49-c5f7-475d-958e-e7dfd2b9e65e", "name": "l(r:p1rdm899-p1rlv857)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e5e11ab-e042-4038-85c4-162521871722"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a28cc17a-125d-4b7b-a697-230e3f8853b5"}}}], "length": {"value": 0.0237034, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "00e35878-599e-4958-ab4e-26fccef53f5a", "name": "l(r:p1rdm899-p1rdt486lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5401d366-a5a2-4753-82b7-ce4fa08a1227"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e5e11ab-e042-4038-85c4-162521871722"}}}], "length": {"value": 0.0374944, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b544e958-00d0-45f4-9f80-ee015a8495ec", "name": "l(r:p1rdt487lv-p1rlv854)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47fbd02f-6c12-4bd6-9d6d-2e0cddbfcd88"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2461b6f0-9a40-4b6f-9669-be479da039f3"}}}], "length": {"value": 0.0160302, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7413aa3e-5264-431e-b1ee-96bcb81dc33c", "name": "l(r:p1rdt488lv-p1rlv863)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e517b810-e6b9-4c89-b47d-1921fcf88edc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09a7be46-a1bf-459d-836b-beb64324809b"}}}], "length": {"value": 0.022533, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ac6a59e2-26a8-4380-a237-b8c62ae89797", "name": "l(r:p1rdm901-p1rlv861)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d7f4223-382b-4b9a-9157-baede39de271"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a07d30f-6909-4d74-be8a-1ff8343b4419"}}}], "length": {"value": 0.0239784, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f1b8fe58-3e64-4bad-a83d-6dfa926eb48b", "name": "l(r:p1rdm901-p1rdt488lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e517b810-e6b9-4c89-b47d-1921fcf88edc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d7f4223-382b-4b9a-9157-baede39de271"}}}], "length": {"value": 0.0134887, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b57aaa4c-0468-4c5f-97d9-03a76be33d9d", "name": "l(r:p1rdt489lv-p1rlv869)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25637062-8ca3-4694-a27b-7be93e89fe1f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fb4003d-498a-494d-89ca-f222d921f63a"}}}], "length": {"value": 0.0208895, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "10466c86-9f76-45e1-94a1-237649c34b3b", "name": "l(r:p1rdm7860-p1rlv7783)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "601a7504-69fc-4c21-a1d8-1a59751d439c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd7a84bb-8aa4-4668-9791-a363741823e9"}}}], "length": {"value": 0.0587046, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b9060d54-e5ed-415c-9385-ff4782908000", "name": "l(r:p1rdm7860-p1rdt3776lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ae14df0-ab3b-47ba-9f83-c09f03999c76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "601a7504-69fc-4c21-a1d8-1a59751d439c"}}}], "length": {"value": 0.0312996, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "fe5691e5-0fea-4743-911a-02ac9e6cc1a0", "name": "l(r:p1rdm7861-p1rlv7784)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "391504f7-3b2f-47f0-aadd-47de5c89b16b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24e665a0-3ba6-46a7-bc02-327b6f77c409"}}}], "length": {"value": 0.0188851, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "60a19095-6b29-4d9b-89a0-147f382ffe6f", "name": "l(r:p1rdm7861-p1rdt3776lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ae14df0-ab3b-47ba-9f83-c09f03999c76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "391504f7-3b2f-47f0-aadd-47de5c89b16b"}}}], "length": {"value": 0.016714700000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b3634258-f4ed-44fb-98e6-aab051e298ed", "name": "l(r:p1rdt3777lv-p1rlv7786)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4662f3f5-e75b-4b75-a6d6-7ada745d5cca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af62e3c-9357-4505-a2f6-3b4252dab81b"}}}], "length": {"value": 0.0847582, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2ded4c2a-d082-4ebc-b7cf-7173851ecbf9", "name": "l(r:p1rdm7862-p1rlv7785)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90158ee6-01aa-48ce-867f-8e459e7a5e09"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1571d1a3-a151-4972-8cb1-aeb36b660abc"}}}], "length": {"value": 0.0135756, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cb94f9fd-5645-4d22-80c7-8bbcc0dd1f34", "name": "l(r:p1rdm7862-p1rdt3777lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4662f3f5-e75b-4b75-a6d6-7ada745d5cca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90158ee6-01aa-48ce-867f-8e459e7a5e09"}}}], "length": {"value": 0.0255604, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "17a69667-cf10-4bca-be13-6a7e0e89b592", "name": "l(r:p1rdt5098lv-p1rlv10453)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e734d7a2-9161-41c0-ba78-9f9f87120acd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09926231-b077-4aa6-afd8-acf89744865a"}}}], "length": {"value": 0.011414400000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "37668bd4-db9e-4657-a30f-6537455366f8", "name": "l(r:p1rdt5098lv-p1rlv10468)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e734d7a2-9161-41c0-ba78-9f9f87120acd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a639e8d-ac8c-46e8-a4b5-6c551612b209"}}}], "length": {"value": 0.010426000000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6f4de8f6-9f4d-4326-879d-2b1d1bd70a9b", "name": "l(r:p1rdt5098lv-p1rlv10482)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e734d7a2-9161-41c0-ba78-9f9f87120acd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d40fc87f-1b73-4ed4-a397-dbc94312dcad"}}}], "length": {"value": 0.0457378, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "eb768007-e1fd-4128-843e-a920a8d99c4a", "name": "l(r:p1rdt5098lv-p1rlv10517)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e734d7a2-9161-41c0-ba78-9f9f87120acd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "efd01236-6ba3-424e-829b-3f3950ce6265"}}}], "length": {"value": 0.0527233, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "81dde824-4245-4f8c-a4cf-9db89dc3aeb4", "name": "l(r:p1rdt5548lv-p1rlv11503)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91754be7-2a91-4a0e-9856-43d08ecc7c70"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "773a6b9e-d708-4f7c-a901-9406bcc3dcde"}}}], "length": {"value": 0.0787524, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "e169b7fb-6b4d-42f9-8e7c-3647a7d1c8a2", "name": "l(r:p1rdt5548lv-p1rlv19645)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91754be7-2a91-4a0e-9856-43d08ecc7c70"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7efbb32-55d4-409b-a37f-bf01d0620d40"}}}], "length": {"value": 0.0664224, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "4eeb407c-9ccf-4bbd-b2fb-d4024fbdc2db", "name": "l(r:p1rdm11706-p1rlv19640)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4c77c78-e261-4d17-93ff-caad4d86246b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e90f763-682e-4771-976c-9cd736b72133"}}}], "length": {"value": 0.0418249, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "a13c699c-045f-49d2-b42c-2cdbede20fb5", "name": "l(r:p1rdm11706-p1rdt5548lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91754be7-2a91-4a0e-9856-43d08ecc7c70"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4c77c78-e261-4d17-93ff-caad4d86246b"}}}], "length": {"value": 0.00976661, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "cc6ab775-6ec1-4a88-8795-fda42a10631d", "name": "l(r:p1rdm11719-p1rlv11513)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15ae4af0-db43-4f1b-bd8c-c6be31d034aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84b9d44e-2c8d-4cee-a9d2-327a41ab8dad"}}}], "length": {"value": 0.0190194, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "7790dc5f-cdac-4888-aef5-99f91b95d8f0", "name": "l(r:p1rdm11719-p1rdt5557lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05b867e6-2f18-49e7-9869-55bd5048c201"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15ae4af0-db43-4f1b-bd8c-c6be31d034aa"}}}], "length": {"value": 0.0164873, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "ebcc125c-7f65-4704-b548-f54176c23576", "name": "l(r:p1rdm11720-p1rlv19574)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "effa94d0-34ae-4cbe-b8da-fd1693d47b3a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf457d88-958c-446a-9584-73be8c609bbe"}}}], "length": {"value": 0.0842106, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "d84a4af5-3ffc-4402-94bf-55e2b8fce113", "name": "l(r:p1rdm11720-p1rdt5557lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05b867e6-2f18-49e7-9869-55bd5048c201"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "effa94d0-34ae-4cbe-b8da-fd1693d47b3a"}}}], "length": {"value": 0.0174341, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "9f3e9279-5951-47ea-9614-bfdb64faa25b", "name": "l(r:p1rdt5560lv-p1rlv11516)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5838960-8556-4e4a-95e9-8ba9ffc85141"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86d82a1e-1596-4fb3-9f3d-44c9553396d2"}}}], "length": {"value": 0.034696700000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a10879ee-8cd7-4421-8ad1-8ec8d159db76", "name": "l(r:p1rdt5561lv-p1rlv11517)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "133a0221-0cd5-46d2-af84-e80e7951c96d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "179d1d84-0dfe-4920-a039-009f33bc1d8d"}}}], "length": {"value": 0.0852615, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "3c9c08f9-58e9-4367-aee8-72788caa6a7c"}}}}, {"uuid": "85c749d5-75af-4616-a6ac-4d19148a2db2", "name": "l(r:p1rdt5564lv-p1rlv11521)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8deb73b9-51fc-447d-9da7-14a6dccff646"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8f0f8a2-f528-45bd-8fbd-22f6699fe7e0"}}}], "length": {"value": 0.0157073, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cea46a51-3c46-4491-91ff-28ee6a01fae5", "name": "l(r:p1rdt5566lv-p1rlv11523)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95a5450a-6630-41b8-863f-0c1f3fcfa7ab"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69eba934-3f80-4abc-b5e8-9cdc79aa05a3"}}}], "length": {"value": 0.0858684, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "86229bfc-1da4-4a19-9237-57b2905f74e0", "name": "l(r:p1rdt5568lv-p1rlv11526)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "613d178b-a566-408d-bad0-e4a170eea971"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b97ebb0-09a4-4c42-a10e-e3aff344aa44"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "945a8612-0351-49e2-9f34-8f08e68f05d1", "name": "l(r:p1rdm11742-p1rlv11533)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0460a67f-dcc1-4829-99f8-7a0b6a8cedbc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21b18539-fba6-4b52-b8bf-38c2a6c4abfb"}}}], "length": {"value": 0.05768530000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "93ae1764-d66b-4a19-906e-591b3a1e591f", "name": "l(r:p1rdm11742-p1rlv19643)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0460a67f-dcc1-4829-99f8-7a0b6a8cedbc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f0e181a-fa89-4c5d-a1cb-6080f91331da"}}}], "length": {"value": 0.0190181, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "3dbe6d40-2137-4381-80f7-1f5a50ac28df", "name": "l(r:p1rdm11742-p1rdt5574lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "248e065d-80ed-4926-9625-295c83da6b61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0460a67f-dcc1-4829-99f8-7a0b6a8cedbc"}}}], "length": {"value": 0.00976661, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "793d8149-e4ef-4652-883e-e9f4c27a7e76", "name": "l(r:p1rdm11743-p1rlv19610)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6554d73d-5cf7-4531-a524-78e70b36fd8d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "813f887e-6807-4ffc-90bf-bd30cde9a9df"}}}], "length": {"value": 0.0248503, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "5cc69a86-7b23-4389-bb35-5abe701b58fd", "name": "l(r:p1rdm11743-p1rdt5574lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "248e065d-80ed-4926-9625-295c83da6b61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6554d73d-5cf7-4531-a524-78e70b36fd8d"}}}], "length": {"value": 0.00976769, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "a326f1c4-da78-4141-9db0-66d576e8b34a", "name": "l(r:p1rdt5577lv-p1rlv11540)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21ef4ae6-b80e-49f1-8d00-1cb6e27bc8f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1148946c-8c37-4482-afce-5082cd2b7ad4"}}}], "length": {"value": 0.0511394, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "12bccd3a-fe76-4b06-b5e9-4ecf0bc45c74", "name": "l(r:p1rdt5577lv-p1rlv11540)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1148946c-8c37-4482-afce-5082cd2b7ad4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f79b14c8-e77d-49c1-9336-e7407ad4c94d"}}}], "length": {"value": 0.00462191, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f0e70843-a66a-4f1c-9ec8-537f478ceb4c", "name": "l(r:p1rdt5577lv-p1rlv19608)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21ef4ae6-b80e-49f1-8d00-1cb6e27bc8f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "752bcf04-7a44-42b0-9a46-44c243b78eb5"}}}], "length": {"value": 0.0743006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "8827a427-b95c-48ee-bab2-53830e656715", "name": "l(r:p1rdt5577lv-p1rlv19608)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "752bcf04-7a44-42b0-9a46-44c243b78eb5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f917b142-d59f-4a51-8c3b-913feb53411d"}}}], "length": {"value": 0.0771446, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9b7200ad-1df7-439b-b20d-bb9280f9771d", "name": "l(r:p1rdm13355-p1rlv13033)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5559c15-cdac-4a4d-a2a0-b99c9befb310"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1564c5f9-8b80-41b4-af09-2a55dee0718b"}}}], "length": {"value": 0.014252, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e1bf48e6-13e2-4a91-89cf-5d84620d1588", "name": "l(r:p1rdm13355-p1rdt6261lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9859b30-0238-493e-be1a-cb6717413ba9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5559c15-cdac-4a4d-a2a0-b99c9befb310"}}}], "length": {"value": 0.0141814, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "aa2af72e-9572-4467-97d9-6b9af030b224", "name": "l(r:p1rdm13356-p1rlv13036)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba5e6363-0b23-4726-8013-f3d040511005"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23aae8f1-8b9f-4453-9643-b49ffdc80889"}}}], "length": {"value": 0.0296258, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2ca1fa28-2d13-4dfb-b49d-74e91cec5353", "name": "l(r:p1rdm13356-p1rdt6261lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9859b30-0238-493e-be1a-cb6717413ba9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba5e6363-0b23-4726-8013-f3d040511005"}}}], "length": {"value": 0.0175481, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "17ea358b-1515-4a7e-b9cc-da4cd723e829", "name": "l(r:p1rdt6262lv-p1rlv13034)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2172b57-622b-44c1-8388-f1e2b1def312"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3b7bff1-90da-4ee2-8a0f-8e291a7e8ac8"}}}], "length": {"value": 0.012931, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cd2a9d82-271b-4297-97f5-86ec2233a7f8", "name": "l(r:p1rdt6262lv-p1rlv13040)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2172b57-622b-44c1-8388-f1e2b1def312"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6839f65-9d3b-4bd6-89a4-0c8feb33e98a"}}}], "length": {"value": 0.012931, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cbc3d861-03cf-41fd-9899-1877d9629f93", "name": "l(r:p1rdt6263lv-p1rlv13035)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4717b000-fd39-4647-9fbd-5152323dacee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6d309ef-b082-4022-a265-4891cdcd6db9"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "5f45d635-24d4-4b92-b676-91cb371f21c7", "name": "l(r:p1rdt6264lv-p1rlv13037)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e916c16-525d-4092-b627-ad44b4bf4ee8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f5d04aa-74fb-4d1a-ac91-6c01a56a94b5"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "f0aff012-ca25-4a95-afab-ae5b5acd6b86", "name": "l(r:p1rdt6265lv-p1rlv13038)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6bb5544-e583-4ded-9a10-23be70f5598e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a8b4502-31fd-4dce-8717-9860880075b4"}}}], "length": {"value": 0.0390031, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "407a9766-0e87-492a-a15d-f38706b3f5d7", "name": "l(r:p1rdt6265lv-p1rlv13039)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6bb5544-e583-4ded-9a10-23be70f5598e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34d43081-e4a3-4f1b-8b90-5965458452d0"}}}], "length": {"value": 0.0390031, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1ecf47fb-4c9d-4c2f-9b13-48fc566a1ff4", "name": "l(r:p1rdt6266lv-p1rlv13041)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8af5f9d5-965c-4a0c-a811-67d3bed744ee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60144ce1-d4d6-4725-b543-f881894356a5"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "97e95d76-b07f-4991-830b-e51976983721", "name": "l(r:p1rdt6267lv-p1rlv13042)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0ddd898-3193-4bff-80f4-fd4a7eae9aec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "296cd07e-c2e3-4031-abad-9c870a65105d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "3867ca21-d32f-4f5c-940d-37211d717384", "name": "l(r:p1rdt6488lv-p1rlv13513)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1155c2c-544c-45f4-969f-b3ec4f6773bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3243ca2f-a97e-4fbc-981d-85eded2e5e6b"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "d02d53af-3a36-4ac6-9b80-9d033180548f", "name": "l(r:p1rdt6578lv-p1rlv13823)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "555453a3-3fb7-426a-bbd2-9e588d4bd01d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0ca6e47-afec-4d61-885a-e38176b32444"}}}], "length": {"value": 0.047603, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "846f4229-8275-4972-b164-2502491188e2", "name": "l(r:p1rdm14192-p1rlv13789)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2fe65b3-6fcc-4416-bca4-9a0f6551b801"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47a7519a-b550-41e6-99e3-c2115db425fe"}}}], "length": {"value": 0.049152900000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6f4fa352-b028-47aa-9d50-18a0bb0a9afe", "name": "l(r:p1rdm14192-p1rlv13796)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2fe65b3-6fcc-4416-bca4-9a0f6551b801"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94ac9254-cdbf-4864-b22b-bcfb0a827700"}}}], "length": {"value": 0.0270402, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0b124dff-b54f-45fa-a5d5-8c433190d495", "name": "l(r:p1rdm14192-p1rdt6578lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "555453a3-3fb7-426a-bbd2-9e588d4bd01d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2fe65b3-6fcc-4416-bca4-9a0f6551b801"}}}], "length": {"value": 0.014767000000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e71fa7ac-b9d3-4a12-b0d7-044c378b6c67", "name": "l(r:p1rdm14194-p1rlv13814)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e0be7c1-65b8-4de4-89f2-56b6bf1ea321"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028d5ead-7c34-400b-bcc1-c4d706c965d3"}}}], "length": {"value": 0.0199421, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "09b39023-2ff0-4d96-a0ed-ac8b59606a15", "name": "l(r:p1rdm14194-p1rdt6578lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "555453a3-3fb7-426a-bbd2-9e588d4bd01d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e0be7c1-65b8-4de4-89f2-56b6bf1ea321"}}}], "length": {"value": 0.0147579, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "57580946-6dbd-4b0c-98d1-8cad145603ef", "name": "l(r:p1rdt6580lv-p1rlv13791)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5de250a8-ecca-4ab4-9f09-685aaf92d13d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "251f270f-4238-4fe6-8ab3-f884fca7a42d"}}}], "length": {"value": 0.021088, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "aa0e6dd2-2c0f-4177-a823-a0468aa4d055", "name": "l(r:p1rdt6580lv-p1rlv13810)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5de250a8-ecca-4ab4-9f09-685aaf92d13d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab29ca66-d59b-4aa6-b5f6-165add0bc331"}}}], "length": {"value": 0.0102831, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7a87292e-c6a6-4051-9120-26457ad60aa0", "name": "l(r:p1rdt6580lv-p1rlv13815)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5de250a8-ecca-4ab4-9f09-685aaf92d13d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99957459-46a6-4b2b-9813-69b11ca7dad1"}}}], "length": {"value": 0.0257571, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cd0d76c4-750e-4a91-bf36-2fc25a0839cf", "name": "l(r:p1rdt6580lv-p1rlv13819)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5de250a8-ecca-4ab4-9f09-685aaf92d13d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36c12a74-a2ca-439a-a69f-308dd5cb1207"}}}], "length": {"value": 0.0290939, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "506334ac-668e-40db-b38e-3b096457209b", "name": "l(r:p1rdt6584lv-p1rlv13817)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d944119-3782-49dd-8b24-1f68d8ee687c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e96bcc5b-07c5-4289-aec4-0224395c5e8a"}}}], "length": {"value": 0.0927796, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f4e84bae-8f8c-4be0-8536-cd28853d2d45", "name": "l(r:p1rdm14215-p1rlv13801)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "39af24f1-0fa2-465e-a288-2b620d9e9d59"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "accec892-a236-462d-b714-1178393ec992"}}}], "length": {"value": 0.0671973, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0a048391-5c17-4012-930f-0b72f82b3505", "name": "l(r:p1rdm14215-p1rdt6584lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d944119-3782-49dd-8b24-1f68d8ee687c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "39af24f1-0fa2-465e-a288-2b620d9e9d59"}}}], "length": {"value": 0.0384386, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "15c6bf63-883d-4801-a272-90fa9b89b00d", "name": "l(r:p1rdm14218-p1rlv13822)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32db643a-7c82-4816-8629-7935cab09567"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ade9991-a857-4619-8094-c18f824aaeb9"}}}], "length": {"value": 0.06771510000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6f9c9704-6507-461c-8562-66721f90efd2", "name": "l(r:p1rdm14216-p1rlv13807)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e81f150f-30cd-4c9a-b5b7-7a633633702d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c26fba44-3b81-47de-81e6-522f2daf0534"}}}], "length": {"value": 0.0529333, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "87f002f2-9fae-464e-bb80-cb01a6a0b754", "name": "l(r:p1rdm14216-p1rdm14218)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32db643a-7c82-4816-8629-7935cab09567"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e81f150f-30cd-4c9a-b5b7-7a633633702d"}}}], "length": {"value": 0.0151179, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b1fec959-7ba6-4215-b96e-6ba2d1d19620", "name": "l(r:p1rdm14218-p1rdt6584lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d944119-3782-49dd-8b24-1f68d8ee687c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32db643a-7c82-4816-8629-7935cab09567"}}}], "length": {"value": 0.0151258, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7c60e0a9-3fcc-4eba-95b4-8df243a36579", "name": "l(r:p1rdt6587lv-p1rlv13808)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c587698-7940-4edb-9105-f31f1304f7e9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c795ac7-3b49-4158-996d-2fb1f0337847"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "00db7f54-776f-48ee-8e74-66239598eba8", "name": "l(r:p1rdt6588lv-p1rlv13809)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61045f72-ca3d-4e0d-ac3d-db5fbf099b38"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "687996da-ab03-4544-b0d9-b79b8ac88e95"}}}], "length": {"value": 0.0528036, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7dd2b848-aa22-4412-b1d1-8022419948bd", "name": "l(r:p1rdt6590lv-p1rlv13820)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a289017a-8ab9-4412-857a-694b3aa2c63d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a2caa70b-9143-4676-834b-bfc7cb41330c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "cce20032-6f5e-4e62-a614-f8c3e1c1e558", "name": "l(r:p1rdt6591lv-p1rlv13821)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a7c2e99-857f-4119-be4a-daaca586f056"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66e6c732-919a-4851-9f76-5580ea71669d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "e2cf222a-6a6e-4c2b-88b3-ae9dc77d477b", "name": "l(r:p1rdt7286lv-p1rlv15585)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ad975da-cce7-49cb-be78-20c4abf8975e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17bf6d8f-8215-4294-b921-cc3e34476f1e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "0b6321c0-e593-4fd0-83ef-ccdacf1bca96", "name": "l(r:p1rdt7289lv-p1rlv15590)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56d21681-3c57-4575-af17-f2bbf9874a10"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef2a4478-4644-4bd3-9548-ab1d0be338b5"}}}], "length": {"value": 0.0486531, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a57e0543-e448-4364-97ea-0ec58bfe1197", "name": "l(r:p1rdt7289lv-p1rlv15591)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56d21681-3c57-4575-af17-f2bbf9874a10"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c04c9ad1-4277-47de-9cec-9ce86e17b4f1"}}}], "length": {"value": 0.0486531, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f9dc052c-0cf6-496a-bdae-32b7e4c0991c", "name": "l(r:p1rdt7293lv-p1rlv15595)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9b0c16f-f433-4aa1-8d00-dc1573dfb5e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "629e2259-2a59-4b20-b8bf-7b3b2c4a48f9"}}}], "length": {"value": 0.0100375, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b490b873-d978-4e8e-b731-5d1a1177b231", "name": "l(r:p1rdt7293lv-p1rlv15598)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9b0c16f-f433-4aa1-8d00-dc1573dfb5e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "af6b7d1b-896f-44ac-8038-748c74507253"}}}], "length": {"value": 0.0100375, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "aaeb1a63-1faf-4245-8aac-9d7ee893de31", "name": "l(r:p1rdm16003-p1rlv15599)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c1ea087-8a4d-49ca-af35-b86aed849c98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ae1bbf1-459f-4346-b525-393b7d1dc958"}}}], "length": {"value": 0.05559190000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6a2caec6-4161-4515-ba83-a4255da193f2", "name": "l(r:p1rdm16003-p1rdt7294lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67d2b31-f05a-4160-83ae-55154224a9ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c1ea087-8a4d-49ca-af35-b86aed849c98"}}}], "length": {"value": 0.0102952, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fd8a75f0-e4cc-4f0d-9f5a-a88b8512defb", "name": "l(r:p1rdm16004-p1rlv15618)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84040096-aca8-4cee-8539-83ae8f875e98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "200aa7d8-0a43-4086-b0e7-f63cae75671d"}}}], "length": {"value": 0.0495647, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2f1ec0c6-1240-41df-9dbd-567f072a135c", "name": "l(r:p1rdm16004-p1rdt7294lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67d2b31-f05a-4160-83ae-55154224a9ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84040096-aca8-4cee-8539-83ae8f875e98"}}}], "length": {"value": 0.0103008, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "228ab804-b7eb-4baa-8890-32957676b9b3", "name": "l(r:p1rdm16011-p1rlv15604)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "381018f1-11cd-4519-ad24-d3419116ea84"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95b45d46-b7e7-46e2-98d9-5034e2fa0a17"}}}], "length": {"value": 0.0544244, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8c2aa039-c379-41ae-a2bc-c5676e9b8d5c", "name": "l(r:p1rdm16011-p1rdt7299lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4cee417a-3410-4907-8621-f0d3fcbc047c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "381018f1-11cd-4519-ad24-d3419116ea84"}}}], "length": {"value": 0.011971, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e8772813-cf45-4c0c-bfb1-0fa439dccaa4", "name": "l(r:p1rdm16012-p1rlv15616)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60d0a9cf-54f3-4049-9957-29839b7beb08"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43ed408e-35e2-4bca-9060-a0c211aea1e7"}}}], "length": {"value": 0.05365020000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e0c373ed-e460-4f34-a8d1-eb847e2f7d41", "name": "l(r:p1rdm16012-p1rdt7299lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4cee417a-3410-4907-8621-f0d3fcbc047c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60d0a9cf-54f3-4049-9957-29839b7beb08"}}}], "length": {"value": 0.011961, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7fc7557d-3188-421b-9deb-23156c311c75", "name": "l(r:p1rdt7300lv-p1rlv15605)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "135a6a49-6562-4c6e-a41f-f5f78c0ac3e6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcbee2ff-bf73-4834-bc3c-46fa0cfcad7c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "fb196b4b-b9e0-4682-9687-fc7b48814c94", "name": "l(r:p1rdt7303lv-p1rlv15608)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7cbc8145-b198-46f1-a3fd-55a05637e618"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13d6bce6-9066-43a1-b2b6-00a2a4398958"}}}], "length": {"value": 0.09331, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e5a601cd-32a4-4b1b-9279-6c052d0a0c67", "name": "l(r:p1rdt7308lv-p1rlv15619)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5094655-6494-44a9-b0ff-c5b418dcc11e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905a4857-5d3d-4e51-9ab0-70d634170f92"}}}], "length": {"value": 0.0449182, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "69eca3e0-a956-498c-b4de-f0459f13be05", "name": "l(r:p1rdt7308lv-p1rlv15641)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5094655-6494-44a9-b0ff-c5b418dcc11e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4363602a-eb9c-41b8-8130-7bb839f4eb5a"}}}], "length": {"value": 0.0129519, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8b756ba9-f09a-4289-8963-ac6c4c3bb912", "name": "l(r:p1rdm16029-p1rlv15623)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2fba947f-089b-47f3-8720-e8f3e35c097c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13f790a1-18c0-498f-8525-fbaf0350947b"}}}], "length": {"value": 0.0220545, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "88313a2a-a20c-49c2-b01d-be23bb684a18", "name": "l(r:p1rdm16029-p1rdt7308lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5094655-6494-44a9-b0ff-c5b418dcc11e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2fba947f-089b-47f3-8720-e8f3e35c097c"}}}], "length": {"value": 0.0183549, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "878d6ef7-4b7f-4b3d-9231-3c35685646c9", "name": "l(r:p1rdm16030-p1rlv15625)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "154999cc-f6d5-458a-8504-e4692344d372"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb08eda2-b277-4bfd-9ea0-9c36765400bd"}}}], "length": {"value": 0.011861000000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "af04168d-2e01-467c-a933-57eb91eefb0e", "name": "l(r:p1rdm16030-p1rdt7308lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5094655-6494-44a9-b0ff-c5b418dcc11e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "154999cc-f6d5-458a-8504-e4692344d372"}}}], "length": {"value": 0.0183492, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "44d47663-a161-4cf0-81dd-d72b5e0b2ec5", "name": "l(r:p1rdt7316lv-p1rlv15632)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a289e26d-2d86-4fdf-942b-881b91ca18eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ccbef4c-6bf7-4892-a3b9-b51aca495137"}}}], "length": {"value": 0.0523363, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3d9c792d-1901-46b8-8dbc-84c2d3351fa6", "name": "l(r:p1rdt7317lv-p1rlv15633)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16c465cf-c4ae-4702-ba6c-0b7704eda764"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce7b60c8-43ee-441d-9f18-5b2722dcc0a7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "a62267fd-b877-4828-8016-462ee6d0d601", "name": "l(r:p1rdt7321lv-p1rlv15640)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c855f7bb-1f33-4c3e-9deb-e3f9c5aba07d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83c2de51-1b04-483c-8ce7-14b9e5e027b9"}}}], "length": {"value": 0.0474361, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c3f2a59a-557e-4560-948b-6a25ec8bf2ef", "name": "l(r:p1rdt7737lv-p1rlv16450)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35be767a-53a1-4fe1-b320-9542dd859d97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5f1e7aa-d93a-4164-8bc0-f920259304a8"}}}], "length": {"value": 0.0142506, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "91de1667-194c-462b-b28f-55a17f4f7220", "name": "l(r:p1rdt7737lv-p1rlv16463)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35be767a-53a1-4fe1-b320-9542dd859d97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9c505d7-3fb9-4eb5-89c6-c9c8da32fd05"}}}], "length": {"value": 0.0227335, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3a01d0fe-40b1-4fb5-91ca-df152fa306f6", "name": "l(r:p1rdt7737lv-p1rlv16507)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35be767a-53a1-4fe1-b320-9542dd859d97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27afe70a-9123-4b0c-9f50-b5355aafcf7a"}}}], "length": {"value": 0.020775, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5c538261-665c-4f36-ba3f-f5e3a08578c7", "name": "l(r:p1rdt7737lv-p1rlv16584)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35be767a-53a1-4fe1-b320-9542dd859d97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "344c6b21-94c9-4912-a19e-69fbae5eed27"}}}], "length": {"value": 0.0280855, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4edf7cf8-7538-4d21-8e74-b279ea148c65", "name": "l(r:p1rdt7753lv-p1rlv16475)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7482f0c-eb85-4e30-a09a-eb9f15bbc22b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d400b1b2-8404-4b80-b110-6f96e000314f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "2037b2b1-5524-4eb7-b64a-da1ecb5f7e62", "name": "l(r:p1rdt7757lv-p1rlv16483)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d343e634-0936-4f21-9e2c-079e19f0dfa1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa6db7ee-126d-4aa9-9733-35ff1c1d5992"}}}], "length": {"value": 0.00228078, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "8d48b987-eaf2-497c-a339-efe11a87bf39", "name": "l(r:p1rdt7757lv-p1rlv16530)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d343e634-0936-4f21-9e2c-079e19f0dfa1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0333a34b-4027-4d9a-9d4a-f867c8a317bc"}}}], "length": {"value": 0.0186713, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8b0bb813-8062-412e-b539-04750931dc13", "name": "l(r:p1rdt7757lv-p1rlv16541)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d343e634-0936-4f21-9e2c-079e19f0dfa1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f7be042-6681-4694-872d-a1cb701016c7"}}}], "length": {"value": 0.0208942, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3d9c040a-bb54-4e9d-81b5-25d6fcbcfc1b", "name": "l(r:p1rdt7791lv-p1rlv16573)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28e5f84f-2fac-4b5c-a669-b16988e4d6ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90d9dbe9-f9c9-4a4e-8ada-cb459778687b"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "af1ad058-7c6a-401b-9fc3-fbfea264ffdf", "name": "l(r:p1rdt7795lv-p1rlv16604)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3959f944-18f5-4daa-a454-3c6bfb7158ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f9ecb3f-8b64-4598-a9d1-d794c6800d33"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "504184a8-1f73-4d48-afa4-2910dbbfa798", "name": "l(r:p1rdt8105lv-p1rlv17239)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b2ec0ba-a854-4631-b97a-4674123d6fe6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba567aae-a893-41d3-8fd1-8357d3cab35d"}}}], "length": {"value": 0.00558108, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b78127ef-db34-49e5-8d34-8d267770eee9", "name": "l(r:p1rdt8105lv-p1rlv17280)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b2ec0ba-a854-4631-b97a-4674123d6fe6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac80cbea-e10a-491a-ba36-06e9fcf74217"}}}], "length": {"value": 0.00558108, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2375fd38-e5df-4013-92a0-781fb802e32a", "name": "l(r:p1rdm17827-p1rlv17246)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3a01639-0851-466b-abc6-adf52342e772"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acfdbe95-2d82-463a-9d1f-6fd2688adf16"}}}], "length": {"value": 0.0396397, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b7c185de-5d32-4bcd-8427-c286259946ea", "name": "l(r:p1rdm17827-p1rdt8111lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b639e55-2e33-4582-bb96-06a9d33a3419"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3a01639-0851-466b-abc6-adf52342e772"}}}], "length": {"value": 0.0160058, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "28b5f84b-cd7d-4034-bdb3-e59c4f80545a", "name": "l(r:p1rdm17828-p1rlv17303)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f70da59-a879-487b-802e-6b7158e425ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04eb7e32-e372-4cb0-94a7-ee418f400bda"}}}], "length": {"value": 0.051430000000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "99397bd6-6958-407d-83b1-af4d43cac71b", "name": "l(r:p1rdm17828-p1rdt8111lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b639e55-2e33-4582-bb96-06a9d33a3419"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f70da59-a879-487b-802e-6b7158e425ca"}}}], "length": {"value": 0.0135199, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0854729a-afef-4d01-8859-67d7f6de1981", "name": "l(r:p1rdt8138lv-p1rlv17291)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dca9b40e-ed8a-4f75-a703-91539f6c3075"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04388b89-16fc-40b3-a060-5bc52032874e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "db220af5-3816-480b-9981-eb1fe35cc177", "name": "l(r:p1rdt8146lv-p1rlv17311)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2bee3961-990e-47ac-b49b-d305f8fe0af8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84ebd9bb-dc50-483d-a3c6-044682d4020c"}}}], "length": {"value": 0.0332245, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0b45d3d6-5c46-46c7-9a97-1f1cf5e43e38", "name": "l(r:p1rdt8167lv-p1rlv17345)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ead5953-70f2-4db2-ba4d-d203c91d85c1"}}}], "length": {"value": 0.0506084, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a4e9e272-25a0-4302-8307-7262bf9ce2f9", "name": "l(r:p1rdt8167lv-p1rlv17357)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf6f74e5-7aa3-4333-bd37-3ce486d54a01"}}}], "length": {"value": 0.0618331, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f0a6e60c-8c24-4e7b-b4ef-7d7ae2b515e9", "name": "l(r:p1rdt8167lv-p1rlv17397)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d38cdffb-41be-48aa-8a03-c6525dd01037"}}}], "length": {"value": 0.0760567, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e1f63203-b54e-40d0-92ec-ae5ba164567c", "name": "l(r:p1rdt8167lv-p1rlv17400)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63177299-2842-4e0d-bf17-7bd2b0afe9a2"}}}], "length": {"value": 0.07573210000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "79e8a7fd-cb8f-4c8b-a89e-4c11077e7b55", "name": "l(r:p1rdt8167lv-p1rlv17405)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b50de14e-9a09-4f61-8998-0979f33b0d0a"}}}], "length": {"value": 0.0505674, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ca4872cb-e641-4360-9f84-ce34923edf34", "name": "l(r:p1rdt8167lv-p1rlv17415)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86b2527b-73c3-41c4-8ac2-7cb0e8bc2a7a"}}}], "length": {"value": 0.061751, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "93491f53-d77b-43a1-a403-c39b07514ecb", "name": "l(r:p1rdt8169lv-p1rlv17347)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6349165a-d47a-4cf4-84f9-df5c5f3a0e98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d98640c6-d8aa-44e4-9ecf-5998152d3f7d"}}}], "length": {"value": 0.0224066, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4ebf0f0a-64e1-4007-b6e9-f21155e3226d", "name": "l(r:p1rdt8169lv-p1rlv17351)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6349165a-d47a-4cf4-84f9-df5c5f3a0e98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2695decb-d268-46b2-8604-9c33dc90518b"}}}], "length": {"value": 0.0609432, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ca6b10dd-667c-47af-be39-98f12b391661", "name": "l(r:p1rdt8169lv-p1rlv17403)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6349165a-d47a-4cf4-84f9-df5c5f3a0e98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d61897a-cdac-4b4a-8812-8a8692a3d958"}}}], "length": {"value": 0.038578400000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "31224941-a62e-42aa-ae90-bd7ccc3abecf", "name": "l(r:p1rdt8174lv-p1rlv17353)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4903e82a-8cfb-406e-b4bf-5e01068419a3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f34e3e4e-bebd-4148-bcc7-cbfbecd73a2f"}}}], "length": {"value": 0.0319504, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "55dc7678-dc68-40c6-ba37-585b326681a7", "name": "l(r:p1rdt8174lv-p1rlv17378)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4903e82a-8cfb-406e-b4bf-5e01068419a3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08709e25-b030-4801-ae00-c4879556d8b1"}}}], "length": {"value": 0.0249412, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d5084996-4e4c-4102-b7a5-52e1080ebde5", "name": "l(r:p1rdt8174lv-p1rlv17383)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4903e82a-8cfb-406e-b4bf-5e01068419a3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e1ad135-904d-47ed-ae74-32b38e1c2f88"}}}], "length": {"value": 0.012372, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ced660f6-d339-46dd-ac3a-27e815f3fec5", "name": "l(r:p1rdt8180lv-p1rlv17361)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8e03b63-853e-4cfe-bf4a-3779b2026637"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c705333f-6f1a-4a76-a02e-eaa859e99b70"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "7ef593a9-0e64-4af1-a4bb-e9b4dc9a4c54", "name": "l(r:p1rdt8195lv-p1rlv17385)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "782d6008-7fec-46b6-9461-9e33b79539d3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e835b413-3307-49ef-ad69-cf18a5ae7cfb"}}}], "length": {"value": 0.014752, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4fa1bae6-7d69-404d-b5a5-f546bb5f877c", "name": "l(r:p1rdt8195lv-p1rlv17387)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "782d6008-7fec-46b6-9461-9e33b79539d3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "55382019-a1a5-40fd-b90a-072af40c2258"}}}], "length": {"value": 0.0249337, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "50184f43-49b4-43eb-ae76-8a7342e55633", "name": "l(r:p1rdt8195lv-p1rlv17391)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "782d6008-7fec-46b6-9461-9e33b79539d3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "169a22de-bb0a-4056-8910-151125c4ff9e"}}}], "length": {"value": 0.04456, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "22e31715-a179-406a-9b84-5870965a7242", "name": "l(r:p1rdt8195lv-p1rlv17407)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "782d6008-7fec-46b6-9461-9e33b79539d3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65de341c-589f-4bf9-a708-26fcc94a6c0a"}}}], "length": {"value": 0.0236267, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "121927ec-fbec-42ba-a8a6-4c6dcc5d1eda", "name": "l(r:p1rdt8195lv-p1rlv17417)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "782d6008-7fec-46b6-9461-9e33b79539d3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67003f0f-6690-469e-82c0-63949ee5241e"}}}], "length": {"value": 0.03781860000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "43975839-0903-4efe-99af-43ae782a4892", "name": "l(r:p1rdt8201lv-p1rlv17394)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76e33e4f-05be-44d1-a503-fed82b4da974"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea560bcb-f930-4f42-ae45-3a60f36fdbb7"}}}], "length": {"value": 0.020193, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ef5666b6-f1d1-4f2d-821e-4d9e2a1463fd", "name": "l(r:p1rdt8201lv-p1rlv17416)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76e33e4f-05be-44d1-a503-fed82b4da974"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64a56527-23a9-4229-aa25-f6a45f2187f4"}}}], "length": {"value": 0.020193, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cd54109f-3a49-4194-850b-5de8de484600", "name": "l(r:p1rdt9055lv-p1rlv19616)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c1f6cd8-cde1-45cc-87ca-1355efa38077"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be1b9922-2426-4726-9e5a-bcd33f444b57"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "c2a1e423-e43a-4b10-bdcb-48a75c970e7c", "name": "l(r:p1rdt9086lv-p1rlv19683)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "afb4c195-8bb6-47d5-88f3-76adb9cda250"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19894180-0890-4585-b4e2-55500af3c41a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "4372152f-0c65-44f9-895a-702b26f19bc7", "name": "l(r:p1rdt16394lv-p1rlv37689)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40b03cbe-470d-493a-854a-900557ac20c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f827fe9e-1ffe-456c-a57b-c3374aef8ad8"}}}], "length": {"value": 0.04723960000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "524c37c2-27e8-46cc-b729-44ebdf5bd414", "name": "l(r:p1rdt16394lv-p1rlv37691)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40b03cbe-470d-493a-854a-900557ac20c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da3cd593-6f05-41ba-9609-f6f1e307e998"}}}], "length": {"value": 0.00410964, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4c9840fc-3d55-44fc-8db0-51dd82d5d450", "name": "l(r:p1rdt16394lv-p1rlv37703)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40b03cbe-470d-493a-854a-900557ac20c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01c9efda-0adf-4932-8f54-2938964371d2"}}}], "length": {"value": 0.0432047, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a76599e2-b880-4448-9ff7-838401b7bccf", "name": "l(r:p1rdt16404lv-p1rlv37710)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38b0bd7c-0898-497f-bb24-4add0fd92932"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38bda697-2888-467e-bab0-62896a62503f"}}}], "length": {"value": 0.0546394, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ffd4c0f2-984f-48ca-ae4a-2d2b8d5eb0bf", "name": "l(r:p1rdt16404lv-p1rlv37732)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38b0bd7c-0898-497f-bb24-4add0fd92932"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d998a0-628e-4009-a6c8-07af906f6d43"}}}], "length": {"value": 0.0546394, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0eeb7dd7-662c-47a3-adc7-5124f65037a5", "name": "l(r:p1rdm37174-p1rlv37776)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58dce206-0571-4a37-b24b-2e674e0c0d3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b24da1e-9a6e-4545-9ad4-a9f0e9675fd1"}}}], "length": {"value": 0.020713, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9d4adf81-a656-46b4-8fdf-bcdddc2d9c0e", "name": "l(r:p1rdm37174-p1rdt16424lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23775c66-0b90-443d-8566-491405876e9d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58dce206-0571-4a37-b24b-2e674e0c0d3b"}}}], "length": {"value": 0.0336785, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2366cce2-64c7-41db-b323-61f0fe2e5dc7", "name": "l(r:p1rdm37175-p1rlv37778)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d21a9584-0fe7-48a6-a46e-ac33e948a471"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5aaed5d-8312-4707-a047-634e433bf49f"}}}], "length": {"value": 0.0194998, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ef783c84-43f7-4a0a-936a-3aaf472a6fb0", "name": "l(r:p1rdm37175-p1rdt16424lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23775c66-0b90-443d-8566-491405876e9d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d21a9584-0fe7-48a6-a46e-ac33e948a471"}}}], "length": {"value": 0.0285662, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8694b9ce-6cbf-4036-a00c-87331245e895", "name": "l(r:p1rdt16427lv-p1rlv37782)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "980376ed-54fd-434c-b58e-0bbd6eaa9954"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d7181ee-ef64-4ded-b619-00ac09d55bf5"}}}], "length": {"value": 0.00573548, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4eae6c4e-f0c8-47ad-9770-7091587932fd", "name": "l(r:p1rdt16603lv-p1rlv38046)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26bc650a-6838-4320-8afa-b8d2f22e96e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10be49a0-301a-4c7e-8ab7-49c14e483079"}}}], "length": {"value": 0.0415295, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "192935c2-108d-4a02-b3ff-d3ac800226fe", "name": "l(r:p1rdt16603lv-p1rlv38047)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26bc650a-6838-4320-8afa-b8d2f22e96e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0935a86b-b9fb-4058-8381-a41f67d6c9dd"}}}], "length": {"value": 0.07748250000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9dfd866d-0648-4a36-9c98-283e673729a5", "name": "l(r:p1rdt16603lv-p1rlv38052)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26bc650a-6838-4320-8afa-b8d2f22e96e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9db6122d-1e51-46ac-9cea-ac436e189cd8"}}}], "length": {"value": 0.0376082, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f4afa825-c031-4375-9b60-796aeee0a73b", "name": "l(r:p1rdt16604lv-p1rlv38048)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d31da07-e20a-4fb8-95f4-d91450395471"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5da7ff68-5f4c-4d56-88fc-7736df03c0bf"}}}], "length": {"value": 0.0117955, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d99baf21-59da-4cbb-9e03-56ef465544aa", "name": "l(r:p1rdt16604lv-p1rlv38050)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d31da07-e20a-4fb8-95f4-d91450395471"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cafc6c03-240d-499d-a3d8-983b554dd007"}}}], "length": {"value": 0.0117955, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5a91da0e-f196-45f7-a32f-1a612d6a008a", "name": "l(r:p1rdt16787lv-p1rlv38414)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4a3b828-bddf-4314-b9a5-03b9dfcd2618"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a25b3511-86cf-404e-944f-273d3f94c05a"}}}], "length": {"value": 0.0187798, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e0ebe0a0-cff4-4adc-a9c9-d828f00e3590", "name": "l(r:p1rdt16787lv-p1rlv38419)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4a3b828-bddf-4314-b9a5-03b9dfcd2618"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6e4595c-0ad9-4501-b86f-c559917d4b86"}}}], "length": {"value": 0.0187798, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "707a4e95-c971-4116-beca-a5ce262f9535", "name": "l(r:p1rdt16790lv-p1rlv38417)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c261090-bc22-4d81-9a9e-75227cd7c99e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "201112bb-3dc7-4a15-9af6-155626ac1ae5"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "cd1a8186-c9d0-42df-b760-b1b95294ef03", "name": "l(r:p1rdt16847lv-p1rlv38535)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1abef1d-4ffc-4696-91ca-e81ac36cce61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0764c32-4f46-473a-9a72-cccc45ae28d7"}}}], "length": {"value": 0.048719200000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4f800f6e-aceb-490a-af1d-44e393867585", "name": "l(r:p1rdt16847lv-p1rlv38536)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1abef1d-4ffc-4696-91ca-e81ac36cce61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ff930f9-63f0-4cab-b74a-3db7eb99f9eb"}}}], "length": {"value": 0.048719200000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b4b5a2d0-160e-402a-b64c-8588848606d6", "name": "l(r:p1rdt16911lv-p1rlv38638)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0df1550a-7e69-42e9-8059-3a36ecb3d253"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a3851f7-2dd3-447b-918f-7a8c954f21d1"}}}], "length": {"value": 0.00340852, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "3b3117b3-95cd-4c2a-824d-0ca04943f253", "name": "l(r:p1rdt383-p1rdt384)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d49257c8-f8eb-4024-9c02-461d18cdd3d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d8cd980-268f-4adb-a6ee-70edf7784542"}}}], "length": {"value": 0.318116, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "93296b51-3b73-4395-b23e-a1fae2d4b519", "name": "l(r:p1rdt383-p1rdt384)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d8cd980-268f-4adb-a6ee-70edf7784542"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7adf2f4b-f0fd-4c53-abcf-d90fe1a2b4c4"}}}], "length": {"value": 0.509093, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c81291a8-f04b-4694-98f0-a6fbd57c43e6", "name": "l(r:p1rdt383-p1rdt7300)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9240d01-bf5d-41ed-8c53-c1f04af1a236"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ac1506-77e9-4b90-ad3d-18be099063a9"}}}], "length": {"value": 0.32156200000000007, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1921e62c-1311-4331-a4a5-2237faa7cb47", "name": "l(r:p1rdt7299-p1rdt7316)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d065da7b-7e88-4e63-a47c-959f4d4c6e1c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6322bf4d-0976-4bae-94c0-f76f83ccb9bf"}}}], "length": {"value": 0.0919841, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bc608943-95fd-47cb-acc2-7387939774bf", "name": "l(r:p1rdt7299-p1rdt7321)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b468be25-1324-46ab-9424-887741ca1134"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d065da7b-7e88-4e63-a47c-959f4d4c6e1c"}}}], "length": {"value": 0.051956600000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "46835e0d-5eec-4eb7-8862-1b1840832c2f", "name": "l(r:p1rdt7308-p1rdt7321)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2e605b4-fe7a-4571-947d-8ae19de627d8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b468be25-1324-46ab-9424-887741ca1134"}}}], "length": {"value": 0.0493128, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c9fea982-3a6d-4605-ba75-13103b955dfa", "name": "l(r:p1rdt7294-p1rdt7308)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a955da2d-e212-4026-b1fb-0021a04ded07"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2e605b4-fe7a-4571-947d-8ae19de627d8"}}}], "length": {"value": 0.06536220000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4ababa0f-34aa-4a8d-9560-2cde2aac808b", "name": "l(r:p1rdt7294-p1rdt7303)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6f24e3a-088a-4d1b-8292-03015289d88e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a955da2d-e212-4026-b1fb-0021a04ded07"}}}], "length": {"value": 0.3131880000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6ccf7fc6-714e-490d-b5be-b1876e6189b0", "name": "l(r:p1rdt7303-p1rdt7317)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48efebbb-c70a-47d3-aae3-0e39088fc455"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e9980c6-3edc-4b4a-be98-cec731419c30"}}}], "length": {"value": 0.34252800000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f7453bad-bc6b-42fc-98f0-7a998cf4dcae", "name": "l(r:p1rdt7303-p1rdt7317)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e9980c6-3edc-4b4a-be98-cec731419c30"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6f24e3a-088a-4d1b-8292-03015289d88e"}}}], "length": {"value": 0.0175612, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "2fbd6f9c-e000-4cd5-97b9-c10833bf3ef6", "name": "l(r:p1rdt7300-p1rdt7317)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05f14a3e-053e-4b65-b962-da7804b9e2c1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48efebbb-c70a-47d3-aae3-0e39088fc455"}}}], "length": {"value": 0.19776300000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "32e79415-33cb-4732-b18b-558714277e5f", "name": "l(r:p1rdt6488-p1rdt7300)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47f8ed28-4bff-47d9-8ffe-4509e9c5b7fc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b96c1e20-68ac-4548-a068-86483c7fa921"}}}], "length": {"value": 0.249926, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a5a2b4bb-a84e-4fbd-8dfa-9a13f2336af4", "name": "l(r:p1rdt6488-p1rdt7300)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b96c1e20-68ac-4548-a068-86483c7fa921"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05f14a3e-053e-4b65-b962-da7804b9e2c1"}}}], "length": {"value": 0.473615, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7a97e04c-3261-43b6-9af9-b42fd68f65e5", "name": "l(r:p1rdt7795-p1rdt9086)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bee93ff6-6ff8-4572-b339-c8e897dac81b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75ee3b24-7407-45ba-94d5-abe187306f13"}}}], "length": {"value": 0.841194, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f85e851f-dc0f-4e6f-a583-3f1ae28d2fe2", "name": "l(r:p1rdt7757-p1rdt7795)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0cd22d3e-1e2a-4a99-9967-b9df95837915"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bee93ff6-6ff8-4572-b339-c8e897dac81b"}}}], "length": {"value": 0.262663, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c80754fc-5960-4d67-a8f1-a5785ee8c97b", "name": "l(r:p1rdt6261-p1rdt6262)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53e5fee4-5a31-448e-8bd0-d8996468d085"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c00c7b1-0aec-4669-9679-cbc1476e0526"}}}], "length": {"value": 0.107372, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6d1cc6e8-e5d0-4689-a499-12aef7ccd279", "name": "l(r:p1rdt6261-p1rdt6262)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c00c7b1-0aec-4669-9679-cbc1476e0526"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf092ec9-ecda-4216-9ac0-0bc035973515"}}}], "length": {"value": 0.0187886, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a9a90a2f-c40a-4110-9de4-a8cb8e889ceb", "name": "l(r:p1rdt6261-p1rdt6263)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53e5fee4-5a31-448e-8bd0-d8996468d085"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c61df077-693e-4e67-aea6-ee60b99406d1"}}}], "length": {"value": 0.228694, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f2d330e4-2f6f-42b5-a13b-cc2a94adeb93", "name": "l(r:p1rdt6261-p1rdt6266)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e22d08f0-2afc-426a-a0c0-6b00cc1103aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cab917a3-5cc2-46d5-9cee-971591841f12"}}}], "length": {"value": 0.435404, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bae0a560-3e11-4f98-b155-63857b58ce6c", "name": "l(r:p1rdt6261-p1rdt6266)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cab917a3-5cc2-46d5-9cee-971591841f12"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53e5fee4-5a31-448e-8bd0-d8996468d085"}}}], "length": {"value": 0.154284, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "38839979-b995-4ab9-be30-6ae67a71c723", "name": "l(r:p1rdt6264-p1rdt6266)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e22d08f0-2afc-426a-a0c0-6b00cc1103aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a03d20d-664a-4e80-abec-a36910787829"}}}], "length": {"value": 0.0739832, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1bd83f42-c21d-47a8-a7a9-1c20e7f83539", "name": "l(r:p1rdt6266-p1rdt6267)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e22d08f0-2afc-426a-a0c0-6b00cc1103aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b6508ce-e51b-4173-8b54-3f3eb7a2cd71"}}}], "length": {"value": 0.325456, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "286e59cc-f63b-468b-8d9a-61393db7e1ee", "name": "l(r:p1rdt6266-p1rdt6267)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b6508ce-e51b-4173-8b54-3f3eb7a2cd71"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a1d9cfa7-0024-4896-a263-2715086f2ad6"}}}], "length": {"value": 0.120044, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0f94cfbd-4761-471c-9562-5e218d822505", "name": "l(r:p1rdt6266-p1rdt8174)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d07105ef-1ba3-4775-aeb4-650b5ea8736e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e22d08f0-2afc-426a-a0c0-6b00cc1103aa"}}}], "length": {"value": 0.262539, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0ea0f6d8-1d8a-446a-b9d5-e7e260e8acd3", "name": "l(r:p1rdt181-p1rdt66)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79d0fee6-369b-4f95-a2d2-cd05232652e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24681ab1-3904-4509-85e6-d9bb1dba4c8e"}}}], "length": {"value": 0.20085399999999998, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "77e9c9e8-25e0-454f-8acc-7bdc292d928a", "name": "l(r:p1rdt253-p1rdt275)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d4e6a87-0313-419f-8feb-7ea3a29f59ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1a85646-be2b-4b15-9c2f-cc603c7e06df"}}}], "length": {"value": 2.31966, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "dfe7b021-ea88-4223-a261-a2701064e836", "name": "l(r:p1rdt275-p1rdt68)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb9e5f0f-8bcf-4019-a786-3f24334e9ae7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8435bee2-05ea-4208-9520-809129624d70"}}}], "length": {"value": 0.43729, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "63205bf8-f4aa-4db4-9485-c23b17d81f7d", "name": "l(r:p1rdt275-p1rdt68)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8435bee2-05ea-4208-9520-809129624d70"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d4e6a87-0313-419f-8feb-7ea3a29f59ae"}}}], "length": {"value": 0.250359, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "be6f7a14-ab8c-4e37-a3ed-5fabff553d05", "name": "l(r:p1rdt280-p1rdt68)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9cb7919-b8bd-46c1-a173-90a5d241c46e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb9e5f0f-8bcf-4019-a786-3f24334e9ae7"}}}], "length": {"value": 0.601429, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "eb7699dc-41c5-4cce-98f5-4ae362b4e94f", "name": "l(r:p1rdt280-p1rdt281)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac745c6f-6e78-4a68-affa-649f91d3aa7c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4425707e-f2b0-419f-828e-a4642ee34b5a"}}}], "length": {"value": 0.0687501, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "72c50a17-a34a-42f4-8b31-08b3bb5f9d75", "name": "l(r:p1rdt280-p1rdt281)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4425707e-f2b0-419f-828e-a4642ee34b5a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9cb7919-b8bd-46c1-a173-90a5d241c46e"}}}], "length": {"value": 1.11596, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "727137fb-8c02-4156-8941-76e9d1959c6a", "name": "l(r:p1rdt181-p1rdt281)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79d0fee6-369b-4f95-a2d2-cd05232652e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac745c6f-6e78-4a68-affa-649f91d3aa7c"}}}], "length": {"value": 0.20523500000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "27e2b305-6b95-45b4-975d-854d614df5dd", "name": "l(r:p1rdt181-p1rdt297)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2fddf29e-6eef-4c60-ad8b-4580440973b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d87f56c0-0a3f-4a94-8f60-1ece461290d0"}}}], "length": {"value": 0.5067780000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "baaa7a29-c4f4-4a42-9496-71615246d038", "name": "l(r:p1rdt3776-p1rdt3777)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "170a2bcb-d7ce-4617-855b-9111b84262ed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f9af980-79c4-4daf-b8fc-44e02953f98b"}}}], "length": {"value": 0.28751, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ab81c681-02cd-4d20-a59a-bf08c0860df2", "name": "l(r:p1rdt270-p1rdt3776)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7eca59ac-01f1-40d7-a0ec-51f355285e01"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6168ebbc-8fd5-49a0-94db-887814eceaba"}}}], "length": {"value": 0.108215, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "07586677-bd64-4204-9ced-d7f05aca7653", "name": "l(r:p1rdt270-p1rdt3776)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6168ebbc-8fd5-49a0-94db-887814eceaba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "170a2bcb-d7ce-4617-855b-9111b84262ed"}}}], "length": {"value": 2.4603700000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "263d110f-a14b-4b87-b223-8da955f62175", "name": "l(r:p1rdt270-p1rdt298)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2c76250-d7ea-4da4-8008-dac1a579e974"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac7c613f-190c-493e-8e89-3ef48e8efdb9"}}}], "length": {"value": 0.28969, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ce9a3964-79b1-4db7-a902-c27cd390c975", "name": "l(r:p1rdt297-p1rdt298)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d32493ec-06be-48ef-959e-779c79c507a3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a468f13-c61f-4c01-aa27-c75fb02030e0"}}}], "length": {"value": 0.19214800000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b7b9dea7-7dc0-419e-b621-97cdac97877f", "name": "l(r:p1rdt297-p1rdt385)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91f76b91-e00a-4a88-8ee8-ec403c2c7d96"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d32493ec-06be-48ef-959e-779c79c507a3"}}}], "length": {"value": 1.01401, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "724c28f1-72e4-4cfa-a5b6-f43bf9859db4", "name": "l(r:p1rdt252-p1rdt385)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22179eaa-fd19-4619-8b31-52bcb36ec683"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91f76b91-e00a-4a88-8ee8-ec403c2c7d96"}}}], "length": {"value": 1.1732, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "026f2218-a9fc-4fcc-8f34-747194feeaa4", "name": "l(r:p1rdt251-p1rdt254)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9c899bc-796a-4e92-88db-6aa11f8777cb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ab802e3-3a0a-413c-8865-e3b3d08e44a8"}}}], "length": {"value": 0.0898381, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0beb9ff2-61e8-46cf-8fd3-44aa828803d1", "name": "l(r:p1rdt258-p1rdt262)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e28087b-b80e-4043-b0f0-0bc82c91f5e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf660777-f77e-4d9b-afff-73a84274c270"}}}], "length": {"value": 0.208153, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "01d3c056-5715-461b-9acc-d66402ab6122", "name": "l(r:p1rdt258-p1rdt261)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "209cebda-044a-42a3-b2f0-fe5b76b80643"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be0fa139-8da7-4cba-9e49-faf4a4814035"}}}], "length": {"value": 0.38624, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f2c4710f-bc68-4564-84af-92a1aa259cb5", "name": "l(r:p1rdt258-p1rdt261)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be0fa139-8da7-4cba-9e49-faf4a4814035"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e28087b-b80e-4043-b0f0-0bc82c91f5e8"}}}], "length": {"value": 0.00488267, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8bb69a39-5b12-4e4f-b027-85e529e0df0b", "name": "l(r:p1rdt261-p1rdt277)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bbe3ac37-aca0-47fd-ac5d-be390cad10ab"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "209cebda-044a-42a3-b2f0-fe5b76b80643"}}}], "length": {"value": 0.627357, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f3609801-4049-4855-a8a0-afaaec9dfde2", "name": "l(r:p1rdt37-p1rdt80)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a2b529c9-4695-42f3-a0e3-69bbb34ff285"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dcbfdc3-b597-4e9e-a86f-4d0ff396ba70"}}}], "length": {"value": 0.120434, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "aa71e0a2-36e9-45a5-8ce4-23aa9fb93fc5", "name": "l(r:p1rdt34-p1rdt77)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a9c4411-f402-464c-ad25-d439b87ef768"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31b06630-2aae-4fe7-9e31-f911c91121cd"}}}], "length": {"value": 0.034869, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4d75f989-6c51-479c-9043-91fcc989f80c", "name": "l(r:p1rdt34-p1rdt38)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b45513a3-8e88-45e9-99d3-6d244c90c256"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a9c4411-f402-464c-ad25-d439b87ef768"}}}], "length": {"value": 0.0394108, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1116ca8a-ac78-49d1-a542-1aa99e1517ef", "name": "l(r:p1rdt31-p1rdt38)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "668d32be-c07a-4387-86a5-e9754af11e9c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b45513a3-8e88-45e9-99d3-6d244c90c256"}}}], "length": {"value": 0.11407100000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "210bf30a-f181-4110-a885-4370b8e42955", "name": "l(r:p1rdt74-p1rdt85)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b82a9a2-b1d1-44eb-a451-946643ef613d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b884fef-8b8f-4ed5-9033-b8177d1c7d70"}}}], "length": {"value": 0.06744590000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4701ebe3-0051-4850-a1be-a674e0d32c1f", "name": "l(r:p1rdt456-p1rdt489)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf205ba7-ac66-4318-aeca-c75eb96cbd1e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cee642e7-12f0-4746-841e-d8cda6fff57e"}}}], "length": {"value": 0.0171007, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7fcd71f7-07a2-4583-92de-d8b76e4fd4fb", "name": "l(r:p1rdt456-p1rdt465)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b092ee09-4c5e-46b5-8ec2-51f99254c220"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf205ba7-ac66-4318-aeca-c75eb96cbd1e"}}}], "length": {"value": 0.0831843, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3d67899c-d0bf-484f-8833-ae3a12e7848e", "name": "l(r:p1rdt46-p1rdt70)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05082892-d69e-4c8f-ba19-c2a627e1c345"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50f3b5f3-3fb5-4fb9-b2e6-b37200af0901"}}}], "length": {"value": 0.0729594, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f96ebf1e-dadb-4961-b8fe-d0177fe34940", "name": "l(r:p1rdt458-p1rdt46)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b61caefd-d5aa-4019-9ac0-aaf8cedc71d0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05082892-d69e-4c8f-ba19-c2a627e1c345"}}}], "length": {"value": 0.139036, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b72cd657-5085-4543-b5f5-8c6a58f68b97", "name": "l(r:p1rdt52-p1rdt72)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2faff95d-f394-427a-9d62-75224f830c9e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6fb1323-f697-4423-a70d-838056200402"}}}], "length": {"value": 0.0184816, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b002135e-3155-4d9a-b8a6-8d2e34cb07e2", "name": "l(r:p1rdt49-p1rdt72)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "137c345c-77cc-4324-bc0e-e0ba896a5f43"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2faff95d-f394-427a-9d62-75224f830c9e"}}}], "length": {"value": 0.141958, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3db69a18-f698-4e11-bb2f-e1e47b900949", "name": "l(r:p1rdt49-p1rdt56)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1d8f5898-7d36-4e40-9980-76d11ef18adb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "137c345c-77cc-4324-bc0e-e0ba896a5f43"}}}], "length": {"value": 0.148385, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "dc672da8-44a3-4894-9c60-5e070b83e7e1", "name": "l(r:p1rdt472-p1rdt56)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fa14b51-a977-4e40-8f9c-28249e576fcf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1d8f5898-7d36-4e40-9980-76d11ef18adb"}}}], "length": {"value": 0.0472436, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c228649f-9ed3-4986-8dac-f0425e9a697a", "name": "l(r:p1rdt458-p1rdt472)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b61caefd-d5aa-4019-9ac0-aaf8cedc71d0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fa14b51-a977-4e40-8f9c-28249e576fcf"}}}], "length": {"value": 0.0781062, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5f1274d2-0fdd-4db3-ba3f-daa46530bbe0", "name": "l(r:p1rdt458-p1rdt468)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04fc215c-7f3e-45e1-a49c-727b0fcdae93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b61caefd-d5aa-4019-9ac0-aaf8cedc71d0"}}}], "length": {"value": 0.11485, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f4afc337-a6c2-4125-b7fe-0719d5e891df", "name": "l(r:p1rdt50-p1rdt53)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c5d8237-0351-4eb2-83e6-13975b37bfa7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7305e2b-0a48-4630-8b8e-c3819f1c9cd1"}}}], "length": {"value": 0.0672176, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "678b9437-c595-43ea-a97d-0017be14cc4d", "name": "l(r:p1rdt50-p1rdt59)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ea7e0bb-bdc5-429a-8889-2f12c94db72e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c5d8237-0351-4eb2-83e6-13975b37bfa7"}}}], "length": {"value": 0.04918, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "60803bca-2ed6-40da-b226-2af544fcb274", "name": "l(r:p1rdt40-p1rdt59)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "577124ac-ea2b-4a60-be47-14b0f5db305e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ea7e0bb-bdc5-429a-8889-2f12c94db72e"}}}], "length": {"value": 0.0516608, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c2559856-65db-4f83-b07d-064dcaedd41f", "name": "l(r:p1rdt40-p1rdt457)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12fef7fc-57f0-4494-becd-4724b84dbbcb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "577124ac-ea2b-4a60-be47-14b0f5db305e"}}}], "length": {"value": 0.0503098, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e0135291-8bce-40e5-95ba-795bc181843a", "name": "l(r:p1rdt457-p1rdt474)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d709af4b-1115-403b-a68d-76c63c93adf2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12fef7fc-57f0-4494-becd-4724b84dbbcb"}}}], "length": {"value": 0.0841745, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b7308a7d-344b-49a7-8d80-685d673ce399", "name": "l(r:p1rdt468-p1rdt474)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5814195b-dd60-4a1e-9af6-b9b84fa4c0c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d709af4b-1115-403b-a68d-76c63c93adf2"}}}], "length": {"value": 0.047055900000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f21f7000-fa58-438d-b295-aeed9c3310fb", "name": "l(r:p1rdt63-p1rdt65)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9397c58-45a1-4ec3-bd84-b4cd5b52dc80"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab2b6727-4d87-4b00-bd49-ba7a6b1b9ce6"}}}], "length": {"value": 0.0933284, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e85cf5e4-69ad-413f-807d-77e3f696eda8", "name": "l(r:p1rdt467-p1rdt65)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ae86125-88c3-44fb-9fe9-1a5d820606f6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9397c58-45a1-4ec3-bd84-b4cd5b52dc80"}}}], "length": {"value": 0.0141041, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a1591c79-b7e3-488b-963c-3d090d44e462", "name": "l(r:p1rdt467-p1rdt469)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48179f57-b0b9-491b-b654-81583768923a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ae86125-88c3-44fb-9fe9-1a5d820606f6"}}}], "length": {"value": 0.045227800000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bf2293fa-d697-40b8-94a8-bbc3360bdc05", "name": "l(r:p1rdt464-p1rdt469)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a634585d-0c70-428e-a3b2-1ec4717d7878"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48179f57-b0b9-491b-b654-81583768923a"}}}], "length": {"value": 0.0950357, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6164d4c1-cfac-48db-b35f-c1fee483f069", "name": "l(r:p1rdt464-p1rdt480)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e5c3d02-1cd2-45e4-90d3-10b135c65f13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a634585d-0c70-428e-a3b2-1ec4717d7878"}}}], "length": {"value": 0.0188143, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "028d1427-12bf-4d80-a0c8-754796fbd8f3", "name": "l(r:p1rdt473-p1rdt480)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76880999-6f79-4fc6-9367-1c419eee26d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e5c3d02-1cd2-45e4-90d3-10b135c65f13"}}}], "length": {"value": 0.100218, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0eac6646-cb23-4f01-9532-2d11c95be7b3", "name": "l(r:p1rdt453-p1rdt473)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1bb6f93-7aed-47d7-99db-7c17352a42b8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76880999-6f79-4fc6-9367-1c419eee26d5"}}}], "length": {"value": 0.0334417, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "550c5f51-4e56-469e-a157-549ea20e8a21", "name": "l(r:p1rdt452-p1rdt453)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d51e6f65-c45c-4f10-a17f-6ef684a0a06c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1bb6f93-7aed-47d7-99db-7c17352a42b8"}}}], "length": {"value": 0.0352317, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "928cf5c6-ff32-4265-a171-caa8f2190066", "name": "l(r:p1rdt452-p1rdt466)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b20fa59a-8573-461a-9c4a-0d47e40d2601"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d51e6f65-c45c-4f10-a17f-6ef684a0a06c"}}}], "length": {"value": 0.13529, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "fd92e905-34f3-437b-8590-4225eebd2e8e", "name": "l(r:p1rdt466-p1rdt478)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64ba6716-89f9-49a4-9793-ba80ae41bcd0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b20fa59a-8573-461a-9c4a-0d47e40d2601"}}}], "length": {"value": 0.100595, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ee3e7c72-665e-47d8-af76-5876a9d9e1c5", "name": "l(r:p1rdt459-p1rdt471)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12d5c579-0570-44db-a751-8eeb92355af9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eed7e6a8-2b4a-4a54-b69a-e3e1a0614213"}}}], "length": {"value": 0.0917334, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5c3199b2-6cca-49c7-aefa-1566475579bf", "name": "l(r:p1rdt459-p1rdt462)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fcfdc5bf-1c87-42e2-8b35-1f7125d3b5ed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12d5c579-0570-44db-a751-8eeb92355af9"}}}], "length": {"value": 0.0703754, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0db2afbf-8d20-4298-92d5-5f6af25ef9eb", "name": "l(r:p1rdt462-p1rdt487)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfb0d992-ab18-4f73-933e-a01ce73ef3b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fcfdc5bf-1c87-42e2-8b35-1f7125d3b5ed"}}}], "length": {"value": 0.0779035, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e9594c65-f9cd-4dd8-801d-a56ca367ddf8", "name": "l(r:p1rdt16787-p1rdt16790)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4774ed1a-85ec-4ca0-8e9a-3b232588fb0c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4bc644c-9875-4846-8b0f-dfa0568de623"}}}], "length": {"value": 0.0992107, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "cadfd571-1a5b-44b9-9fb5-de61bc3fedf8", "name": "l(r:p1rdt16790-p1rdt16911)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4774ed1a-85ec-4ca0-8e9a-3b232588fb0c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d29266e8-ce67-45bf-93d9-710d4684ce0b"}}}], "length": {"value": 0.388046, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "029ca061-b298-4b43-8c5a-f7ac6278b9be", "name": "l(r:p1rdt16790-p1rdt16911)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d29266e8-ce67-45bf-93d9-710d4684ce0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "725fbd98-74ba-4143-8947-da9fdc209889"}}}], "length": {"value": 3.63254, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b2c407c7-c4ae-4f38-879d-6ee603c0a3ac", "name": "l(r:p1rdt16790-p1rdt487)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d53ff9fd-2b16-4026-88fa-2c112d4949c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a1b5b099-df99-4729-a26d-f0882e93136f"}}}], "length": {"value": 0.110567, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f2ae3c18-4521-4101-98d7-6eb006416a16", "name": "l(r:p1rdt16790-p1rdt487)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a1b5b099-df99-4729-a26d-f0882e93136f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4774ed1a-85ec-4ca0-8e9a-3b232588fb0c"}}}], "length": {"value": 5.746810000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9061f19a-d9eb-48b0-9aa6-ee230b7b9499", "name": "l(r:p1rdt484-p1rdt487)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b57b8e2b-62c2-49a0-801d-02cab8092ebd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfb0d992-ab18-4f73-933e-a01ce73ef3b2"}}}], "length": {"value": 0.0512407, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0a5c4a2b-b730-4d42-aa11-f36b01a58a20", "name": "l(r:p1rdt484-p1rdt486)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd2f4b00-6e8b-4faa-a760-7c28f8d36a36"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b57b8e2b-62c2-49a0-801d-02cab8092ebd"}}}], "length": {"value": 0.0914543, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e4317dc5-b30e-44c0-a5fc-e0c630cfe5d6", "name": "l(r:p1rdt482-p1rdt486)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10c2463d-8563-4737-aa7d-e1195c0af9f6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd2f4b00-6e8b-4faa-a760-7c28f8d36a36"}}}], "length": {"value": 0.018752, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ea04bd86-9e92-4818-a4ff-74fa02d6a46e", "name": "l(r:p1rdt482-p1rdt485)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4064b6c-40b4-418b-95ab-4f9bb0363b14"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10c2463d-8563-4737-aa7d-e1195c0af9f6"}}}], "length": {"value": 0.103372, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "256555f0-2f34-42b5-b04a-e8766a7dd987", "name": "l(r:p1rdt476-p1rdt477)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d1eb09d-dff4-4fa3-b96f-ef59b63d6128"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5421facb-0713-404c-97e9-56669fc762b3"}}}], "length": {"value": 0.0550546, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a651515b-87f2-44e9-827e-68ed7e4d130e", "name": "l(r:p1rdt477-p1rdt479)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85acd1fb-6da3-432a-9508-855ca991641b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d1eb09d-dff4-4fa3-b96f-ef59b63d6128"}}}], "length": {"value": 0.06993920000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8f1ebb1d-e621-479d-aa1b-1d0fea5807b5", "name": "l(r:p1rdt454-p1rdt479)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "82459f47-0c6f-4173-8c35-5a9fe5db9713"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85acd1fb-6da3-432a-9508-855ca991641b"}}}], "length": {"value": 0.0357544, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f6e2d9ab-2762-48b9-8da9-cc62bc28adae", "name": "l(r:p1rdt454-p1rdt455)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "183de04a-a665-4112-a912-1df68b61d164"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "82459f47-0c6f-4173-8c35-5a9fe5db9713"}}}], "length": {"value": 0.0689016, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4816e19f-838d-41f2-a889-d1697bb121b3", "name": "l(r:p1rdt455-p1rdt460)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59b616e5-76b8-406c-843f-5c71398af81b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "183de04a-a665-4112-a912-1df68b61d164"}}}], "length": {"value": 0.0565594, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8ca3ee16-bba0-44b3-a3dd-3ea6a58222ea", "name": "l(r:p1rdt460-p1rdt470)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59b616e5-76b8-406c-843f-5c71398af81b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86178159-ccd7-45a3-b711-ac237321d52a"}}}], "length": {"value": 0.106222, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "06b66ecc-6e3f-4117-a516-0557d7bb1370", "name": "l(r:p1rdt460-p1rdt483)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69b5d686-dae0-44c5-a261-f1a73bcb168e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59b616e5-76b8-406c-843f-5c71398af81b"}}}], "length": {"value": 0.106104, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7bdb4c42-40ee-4d95-8b61-c34a1e59a269", "name": "l(r:p1rdt483-p1rdt485)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d899b807-b194-4f65-bad5-a39e8bc61906"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69b5d686-dae0-44c5-a261-f1a73bcb168e"}}}], "length": {"value": 0.19624000000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ca24f954-e522-4093-b3ca-f315003201e2", "name": "l(r:p1rdt279-p1rdt89)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "232adbbb-2715-44be-8db5-ee062ebf4e46"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "416118a8-65b7-4d9e-90a2-454f065bfddb"}}}], "length": {"value": 0.30139, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "49d16b3e-d9c3-46dd-95bb-e5daf8e7a58c", "name": "l(r:p1rdt279-p1rdt89)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "416118a8-65b7-4d9e-90a2-454f065bfddb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac4ad276-90cb-48c0-bfd0-1f2aa0233ce2"}}}], "length": {"value": 0.197349, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a29ed3d7-71e4-416f-abb4-38952e31a0a5", "name": "l(r:p1rdt16424-p1rdt16427)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d50d3e76-470b-47c2-ada2-da944962b322"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "18e3da78-83fc-4b8e-9d45-41adb9b753ad"}}}], "length": {"value": 0.112509, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ecf392c2-a6e6-4d2c-8690-e08a70243f01", "name": "l(r:p1rdt16427-p1rdt16847)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e35a4f7-19c1-4f59-9adc-b267f6088264"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a6382a2-8c21-4cb4-a39b-3f1ac62cc705"}}}], "length": {"value": 0.160318, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b33f1be7-ab62-4068-9cdd-a6b06ddb0dd2", "name": "l(r:p1rdt16427-p1rdt16847)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a6382a2-8c21-4cb4-a39b-3f1ac62cc705"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d50d3e76-470b-47c2-ada2-da944962b322"}}}], "length": {"value": 3.5139, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "81012bf1-6b78-4db4-9e2c-bad624e98440", "name": "l(r:p1rdt16404-p1rdt16847)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61d5dee2-30f8-434d-8c03-76bccff72549"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e35a4f7-19c1-4f59-9adc-b267f6088264"}}}], "length": {"value": 1.15724, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9ae94c4c-3829-4c79-9e4a-a9d47c147dd6", "name": "l(r:p1rdt16394-p1rdt16404)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5b51836-1807-4fab-b877-94a62021569f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61d5dee2-30f8-434d-8c03-76bccff72549"}}}], "length": {"value": 0.518625, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a4046167-8caa-4f89-90f0-2f76d4ead86f", "name": "l(r:p1rdt16394-p1rdt16603)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5a9e0f5-d824-4a76-a4f0-88aab072280e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5b51836-1807-4fab-b877-94a62021569f"}}}], "length": {"value": 0.709035, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3583561b-9771-4681-a564-fd0842692302", "name": "l(r:p1rdt16603-p1rdt16604)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98a946e8-3c8a-49ec-be8a-5610c7fc596c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5a9e0f5-d824-4a76-a4f0-88aab072280e"}}}], "length": {"value": 0.17277, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "906bae77-46ff-4ffe-aa1a-8abca937d44b", "name": "l(r:p1rdt16604-p1rdt257)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ef71bd7-4c82-4296-a6ac-64516ffe96c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "282d8a89-8b14-476b-9e55-b310d8b9396d"}}}], "length": {"value": 0.261511, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "fd814da9-2a6f-4e0b-b2a0-78a6ae1902b8", "name": "l(r:p1rdt209-p1rdt257)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcb27aab-e828-41a6-ad98-d197897a1a69"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fb307f7-3690-4931-999a-4daab4d8c9e5"}}}], "length": {"value": 0.76493, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "071d214f-abee-4f75-a132-0f7658f857bb", "name": "l(r:p1rdt209-p1rdt210)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d782d5e-3960-415c-9e33-6742777a5a0a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcb27aab-e828-41a6-ad98-d197897a1a69"}}}], "length": {"value": 0.184587, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "530e99b6-8a7f-4641-903b-78a595344f17", "name": "l(r:p1rdt211-p1rdt278)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9401940-26a4-40f3-9b9a-5231a5c4e171"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b89bfea1-97cd-41f7-af59-9602a3fc6c06"}}}], "length": {"value": 0.23979600000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d122d673-6fba-4f7f-84e6-34ad0b010b7b", "name": "l(r:p1rdt210-p1rdt211)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d782d5e-3960-415c-9e33-6742777a5a0a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9401940-26a4-40f3-9b9a-5231a5c4e171"}}}], "length": {"value": 0.156188, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "59cdecc0-9e7a-45b1-97e7-6faaaa4f4ffa", "name": "l(r:p1rdt210-p1rdt44)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1be5e34-ad5e-4c78-8067-8e0194c661a4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d782d5e-3960-415c-9e33-6742777a5a0a"}}}], "length": {"value": 1.1888300000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "11448296-bdc4-4e49-9f35-5b5f6fcea1ef", "name": "l(r:p1rdt259-p1rdt44)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0b5743e-c3fd-49c7-879e-9be7d00c480f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33a0a070-9cce-4a82-bd22-24a65f02ef97"}}}], "length": {"value": 0.515436, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "929db262-2207-4a98-873f-3fe8228c418b", "name": "l(r:p1rdt43-p1rdt47)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7728581d-66fc-4e7e-b2b0-85fa02c90523"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ea0531d-530c-4088-86a1-3de96a8938ea"}}}], "length": {"value": 0.165779, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8725d8ec-6b1e-43d3-aac1-c50e038ef687", "name": "l(r:p1rdt48-p1rdt51)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1667a8c6-aeb4-4f22-97b8-62ffefcc12a4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f5cef5c-bcaf-4cd9-afbb-a18bd14dfcd4"}}}], "length": {"value": 0.04269860000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ef4f28ba-8efb-4df9-b243-d434142431d2", "name": "l(r:p1rdt43-p1rdt48)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7728581d-66fc-4e7e-b2b0-85fa02c90523"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1667a8c6-aeb4-4f22-97b8-62ffefcc12a4"}}}], "length": {"value": 0.175272, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5cc6da99-b1cd-4ddb-a42e-7a75db0bf7a7", "name": "l(r:p1rdt43-p1rdt60)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d99e903-3536-4a73-b0d5-ca11f5af6e32"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7728581d-66fc-4e7e-b2b0-85fa02c90523"}}}], "length": {"value": 0.0427769, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6df6cf40-acb9-42fb-99e3-a21ce4101b90", "name": "l(r:p1rdt58-p1rdt60)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a4ccf80-2611-4089-9353-439809aa7854"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d99e903-3536-4a73-b0d5-ca11f5af6e32"}}}], "length": {"value": 0.0448322, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c70146f3-efa7-47d1-9cbb-88314168e430", "name": "l(r:p1rdt58-p1rdt69)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7238345a-1fc7-4f3f-bc8b-88cf7582c75c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a4ccf80-2611-4089-9353-439809aa7854"}}}], "length": {"value": 0.0519836, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "cfb6c001-f792-4ff8-95cf-625dea85b422", "name": "l(r:p1rdt61-p1rdt71)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bcea1fd6-3c51-48af-8528-d3d7bc8e4f01"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "744725a8-af2a-47cf-948f-9d453a932e32"}}}], "length": {"value": 0.0913144, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "98b2bf94-0765-4f57-860d-b02450dd0b62", "name": "l(r:p1rdt150-p1rdt71)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eab6b8c5-ee7a-4779-b5eb-5205dbe5253c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf5b238a-832f-4f45-8a36-2248549e1723"}}}], "length": {"value": 0.0753659, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d510bfdb-9843-422e-8bb1-2f789219abfc", "name": "l(r:p1rdt150-p1rdt71)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf5b238a-832f-4f45-8a36-2248549e1723"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bcea1fd6-3c51-48af-8528-d3d7bc8e4f01"}}}], "length": {"value": 1.27669, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "de6d22bc-1b8f-4f30-bb8b-c8da620b8eba", "name": "l(r:p1rdt374-p1rdt376)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f2a0358-b10d-4b62-8f8d-9a5054fae87d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d425a00d-c0e9-465d-9d9b-af4d64708fba"}}}], "length": {"value": 0.108011, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ff7901c8-0aff-456b-8d81-a1b8d4a2f3b2", "name": "l(r:p1rdt335-p1rdt376)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0de112ae-d04a-4673-98af-0699e4890429"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f2a0358-b10d-4b62-8f8d-9a5054fae87d"}}}], "length": {"value": 0.20898, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5298fbca-8076-473f-8580-b288d0c98374", "name": "l(r:p1rdt415-p1rdt417)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "101c6236-a474-45c8-b065-f5fa045b1107"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "71fa675e-bc20-46f7-b6f1-c88962f9f3cb"}}}], "length": {"value": 0.074738, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e5c8a281-4e52-4e82-9f86-f4ff7e5c363d", "name": "l(r:p1rdt415-p1rdt419)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19116f3c-29ae-4819-ba72-dd0f8afa5078"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "101c6236-a474-45c8-b065-f5fa045b1107"}}}], "length": {"value": 0.232463, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d9a13636-4929-4a92-891e-92960b15b975", "name": "l(r:p1rdt180-p1rdt5098)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9100fbd6-863e-48b2-94ed-aca1ef0947bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5258d4de-be4c-478d-b752-7f4efb0af0a5"}}}], "length": {"value": 0.41780500000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d3025355-e4bb-43e1-8a1f-b9bd5316b188", "name": "l(r:p1rdt6578-p1rdt6584)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9f273a36-c30d-4962-81f4-26f8d20e1cf4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e257530-1fe2-410b-83a1-57789e6ddeda"}}}], "length": {"value": 0.0679586, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9aa5d5e1-1d2f-4b82-a77d-c3f2172ae856", "name": "l(r:p1rdt6584-p1rdt6588)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9f273a36-c30d-4962-81f4-26f8d20e1cf4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1648fe3-a7f9-47aa-b168-d2b56cf220e7"}}}], "length": {"value": 0.0883424, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1eba036d-0e03-407a-85b6-8ba160dad1b3", "name": "l(r:p1rdt6590-p1rdt6591)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1d0a85a-62dc-46d2-bae1-d43d07743a34"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5291ea2b-6990-407b-b8d4-d6868bf37310"}}}], "length": {"value": 0.043231000000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a5bf29ac-89bd-4638-b20b-ed48bd580674", "name": "l(r:p1rdt6584-p1rdt6591)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9f273a36-c30d-4962-81f4-26f8d20e1cf4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1d0a85a-62dc-46d2-bae1-d43d07743a34"}}}], "length": {"value": 0.125784, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f6953e73-a087-4102-a892-1ebe433cef19", "name": "l(r:p1rdt6584-p1rdt6587)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d77add8e-ba22-4b44-9c0b-0bddc251a573"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b918e583-d163-4136-aaf8-62085c7b0c17"}}}], "length": {"value": 0.115903, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f95cb8d3-6bac-4f3f-9987-04072432b638", "name": "l(r:p1rdt6584-p1rdt6587)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b918e583-d163-4136-aaf8-62085c7b0c17"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9f273a36-c30d-4962-81f4-26f8d20e1cf4"}}}], "length": {"value": 0.0307942, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f6679ba4-efdc-4874-8d11-4cf6f748a362", "name": "l(r:p1rdt6580-p1rdt6587)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68298e92-fca3-44e9-9271-f79be47c9c63"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d77add8e-ba22-4b44-9c0b-0bddc251a573"}}}], "length": {"value": 0.286666, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "818206bb-ebe5-4922-a8c2-df51bbeaebf3", "name": "l(r:p1rdt5098-p1rdt6580)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9100fbd6-863e-48b2-94ed-aca1ef0947bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68298e92-fca3-44e9-9271-f79be47c9c63"}}}], "length": {"value": 0.782623, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "de8392a4-82a2-4c6f-9329-507a13f1a963", "name": "l(r:p1rdt5098-p1rdt8169)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb3d775d-8d92-498b-989c-387278ec8e9e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9100fbd6-863e-48b2-94ed-aca1ef0947bd"}}}], "length": {"value": 0.639283, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "76bbbb7c-66cd-4a27-99f1-bb859a6066fd", "name": "l(r:p1rdt414-p1rdt418)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16b7f1e9-3405-4c5f-96c7-d5c08d791907"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3034e62-dd19-4ecb-bb39-6d0566e3a2ef"}}}], "length": {"value": 0.140409, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1a1011d6-d015-42ba-ac6e-da7e2a76d943", "name": "l(r:p1rdt416-p1rdt418)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16b7f1e9-3405-4c5f-96c7-d5c08d791907"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba78164d-d6ae-413b-8d24-067d8d38b28f"}}}], "length": {"value": 0.317261, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ddd205c9-12db-4ebd-8427-ef30fb02d0cd", "name": "l(r:p1rdt416-p1rdt418)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba78164d-d6ae-413b-8d24-067d8d38b28f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d16d5f5e-a376-4e39-a845-d2cde8800da3"}}}], "length": {"value": 0.00719095, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1ef9f953-073c-41dc-9fab-1bb29279ed90", "name": "l(r:p1rdt418-p1rdt8201)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e3d41a7-06a4-460b-aa6c-3a60c8d2de10"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16b7f1e9-3405-4c5f-96c7-d5c08d791907"}}}], "length": {"value": 0.383696, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "52d6e202-09f8-43f8-a1e1-d5a09e7a420b", "name": "l(r:p1rdt8180-p1rdt8201)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63928702-c44a-4e83-9cca-7ce77bdbd2b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e3d41a7-06a4-460b-aa6c-3a60c8d2de10"}}}], "length": {"value": 0.144684, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1b5efc51-00cf-4947-b82a-1d0bc2f4a0ce", "name": "l(r:p1rdt6265-p1rdt9055)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "246ad62e-5a10-4031-94e7-1732f58f1da9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cd9ea283-dbd2-4f38-b298-86a191c99bd2"}}}], "length": {"value": 0.418878, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d2ad08b2-3802-428b-90bc-4116ddde21dc", "name": "l(r:p1rdt6265-p1rdt9055)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cd9ea283-dbd2-4f38-b298-86a191c99bd2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d316c13-77c1-4412-baf9-801f7e5ae407"}}}], "length": {"value": 0.0741307, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6784aa1f-ad7a-4d72-bb32-3a288b673f0f", "name": "l(r:p1rdt5560-p1rdt9055)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30adfcd5-405b-47ea-be54-55c5a47c835f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "708f65d6-b869-4d26-930d-0e669caf4ffb"}}}], "length": {"value": 0.254007, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "fc1f504a-bedc-4016-b92a-65b5bc1fe559", "name": "l(r:p1rdt5560-p1rdt9055)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "708f65d6-b869-4d26-930d-0e669caf4ffb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "246ad62e-5a10-4031-94e7-1732f58f1da9"}}}], "length": {"value": 0.116066, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "660f83ca-a09b-4b56-aa68-675d218b0194", "name": "l(r:p1rdt7737-p1rdt7753)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d2ea25e-3d48-4b1d-9e52-768752de2e09"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d142315b-a247-4a4d-a178-73e3c150a188"}}}], "length": {"value": 0.0669715, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "48e7142e-612f-4100-8d25-23220ea89d75", "name": "l(r:p1rdt7737-p1rdt7791)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4413ca7f-fdd1-484e-a0ba-3ff2447ebfef"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0946738d-95de-4ad6-9d56-c043cb64c0e4"}}}], "length": {"value": 0.249534, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e62453e6-b369-467e-88c6-b611ede7388d", "name": "l(r:p1rdt7737-p1rdt7791)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0946738d-95de-4ad6-9d56-c043cb64c0e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d2ea25e-3d48-4b1d-9e52-768752de2e09"}}}], "length": {"value": 0.0184373, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "37724e03-70aa-4ea1-8b09-81dd8f5d16fa", "name": "l(r:p1rdt7286-p1rdt7791)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02351140-e632-49e2-83e4-7e5bc1c8856a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4413ca7f-fdd1-484e-a0ba-3ff2447ebfef"}}}], "length": {"value": 0.158647, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "62eb02c6-39e5-4a17-8074-8f98b78fcba3", "name": "l(r:p1rdt7286-p1rdt7289)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f8375b7-7bdd-409c-9fa1-5c13bd233364"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02351140-e632-49e2-83e4-7e5bc1c8856a"}}}], "length": {"value": 0.04388460000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "df4ec83d-e66f-4915-88ba-7af7ae387aea", "name": "l(r:p1rdt7289-p1rdt7293)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f8375b7-7bdd-409c-9fa1-5c13bd233364"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4afa9bec-d8da-4449-ab96-9f875bae3c33"}}}], "length": {"value": 0.16261800000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a4c26044-940e-462b-9054-1e0d4b8c36e4", "name": "l(r:p1rdt5568-p1rdt7289)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c83b6ee-20fc-4ca0-a778-44735283afd5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f8375b7-7bdd-409c-9fa1-5c13bd233364"}}}], "length": {"value": 0.600473, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a4279547-718a-4091-8aa8-b7d14015a34a", "name": "l(r:p1rdt5551-p1rdt5568)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8aa126c-9b2b-4ae0-a4fc-36d4201762a0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65eb08cf-6350-410a-88c2-3b318d3a262a"}}}], "length": {"value": 0.0882294, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1369a137-ea26-496f-a49e-07fe1c36db1c"}}}}, {"uuid": "60d3b874-c356-4c2d-8bcd-365734606fc3", "name": "l(r:p1rdt5551-p1rdt5568)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65eb08cf-6350-410a-88c2-3b318d3a262a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64aba8d5-1dd3-4741-a8ba-26801e275ba8"}}}], "length": {"value": 0.0161184, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a6b9e998-dc46-46e3-b86b-5d83295608dd", "name": "l(r:p1rdt5548-p1rdt5577)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c49b671-0b2b-43c9-bcb5-21c7b7e716ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fead5749-3ba7-4ead-a604-e8adbd18f8c2"}}}], "length": {"value": 0.160305, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1369a137-ea26-496f-a49e-07fe1c36db1c"}}}}, {"uuid": "7ddab2ca-bfb1-4594-b119-011f70f0dd90", "name": "l(r:p1rdt182-p1rdt304)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c51ccb17-eed6-4ce0-b839-e7b26001fe3e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08e378d4-4ca6-4c9e-93fa-36ff87a3cf0f"}}}], "length": {"value": 0.7293, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "129d30ae-597e-45cf-b893-7a0bf9dba703", "name": "l(r:p1rdt304-p1rdt305)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b936973-54dc-41e7-a413-8932c31f0793"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c51ccb17-eed6-4ce0-b839-e7b26001fe3e"}}}], "length": {"value": 0.171066, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "86281a7e-9023-4f94-a293-57e7d50db505", "name": "l(r:p1rdt303-p1rdt305)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9672c49b-8316-4907-b204-7505483210b0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b936973-54dc-41e7-a413-8932c31f0793"}}}], "length": {"value": 0.3440750000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "312c6354-e82f-404e-8e44-2dcf1c65f8bf", "name": "l(r:p1rdt177-p1rdt303)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ad84ef4-4dcc-42f7-99ed-b8d21cebc465"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9672c49b-8316-4907-b204-7505483210b0"}}}], "length": {"value": 0.47439500000000007, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f5774d9c-24b9-411c-a015-e6e4b59caef7", "name": "l(r:p1rdt178-p1rdt306)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57a78c71-e5a8-4dfd-8359-e368b7b198fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6912a245-ac1c-4ddd-b021-3bc35cbbe2c5"}}}], "length": {"value": 1.21943, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c7cb6ba7-cba6-40f8-a51e-07fb728cc8a3", "name": "l(r:p1rdt177-p1rdt306)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ad84ef4-4dcc-42f7-99ed-b8d21cebc465"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57a78c71-e5a8-4dfd-8359-e368b7b198fa"}}}], "length": {"value": 0.644981, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0217c83c-f2af-4c1c-ac7f-0a81411e1e63", "name": "l(r:p1rdt177-p1rdt8105)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3f91816-7c3f-4fc7-98a5-6dee55e52e9f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ad84ef4-4dcc-42f7-99ed-b8d21cebc465"}}}], "length": {"value": 1.4039100000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "2ed246a3-dfad-450b-b7f1-ab6f298571c4", "name": "l(r:p1rdt8105-p1rdt8111)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2c69fef-4afb-4bb3-9828-096b812de54a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37229b7c-80a2-4d01-af6a-818bdfcc1f54"}}}], "length": {"value": 0.0910676, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "12928856-aaca-4156-8f34-04878d8ad992", "name": "l(r:p1rdt8105-p1rdt8111)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37229b7c-80a2-4d01-af6a-818bdfcc1f54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3f91816-7c3f-4fc7-98a5-6dee55e52e9f"}}}], "length": {"value": 0.186172, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "aa0b22a4-6d2d-44c3-bf03-9f5e189ed04f", "name": "l(r:p1rdt8111-p1rdt8146)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2c69fef-4afb-4bb3-9828-096b812de54a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc34073b-94f6-4c75-8144-8f624bac9cc7"}}}], "length": {"value": 0.0135199, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bd0c3d35-c8cb-4701-b32e-a31567ad572d", "name": "l(r:p1rdt8111-p1rdt8138)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9929e0d4-3e33-4f5f-b718-6a629cc52242"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3a54311-da27-45d7-95c3-eee07761fbe4"}}}], "length": {"value": 0.198155, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "817adbcf-58d7-4cf2-b4cb-c18d1bc0c604", "name": "l(r:p1rdt8111-p1rdt8138)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3a54311-da27-45d7-95c3-eee07761fbe4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2c69fef-4afb-4bb3-9828-096b812de54a"}}}], "length": {"value": 0.00299557, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "95236d9f-791c-4a01-a0fd-cb767ec941fa", "name": "l(r:p1rdt251-p1rdt252)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b801037a-e1bb-4c5c-8d18-ed285c8c1d3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69b2ee46-ab5f-48c8-a26b-170ed2b57fcb"}}}], "length": {"value": 0.0455935, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "c1ec8649-6347-41c8-8e9c-1a2e0a37841e", "name": "l(r:p1rdt251-p1rdt446)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3dfe357-889d-42e0-a59a-821c9f843456"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b801037a-e1bb-4c5c-8d18-ed285c8c1d3b"}}}], "length": {"value": 0.620095, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "02b836f0-26df-4939-85a9-506b1779e82b", "name": "l(r:p1rdt468-p1rdt481)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cf3136f-6dbe-4ed7-b9cb-e9f73b191f76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a180b972-cf0e-4a2e-9bcf-a0ad90bb3d83"}}}], "length": {"value": 0.100395, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "dcd73329-a55d-4e12-a3ff-f205c33136f3", "name": "l(r:p1rdt475-p1rdt481)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c39140c6-8892-480a-81b9-738c67ed1591"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cf3136f-6dbe-4ed7-b9cb-e9f73b191f76"}}}], "length": {"value": 0.0369015, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "a299d137-b589-4bab-9836-867f1cdfec55", "name": "l(r:p1rdt461-p1rdt475)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc35f44e-d8d9-41d0-b014-caa3d8d7a91e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c39140c6-8892-480a-81b9-738c67ed1591"}}}], "length": {"value": 0.0590418, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "cc87ca48-40d2-40fa-9407-459ef56a38b8", "name": "l(r:p1rdt461-p1rdt478)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eba354c-f4bf-4c49-a8ad-998ab9489e5a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc35f44e-d8d9-41d0-b014-caa3d8d7a91e"}}}], "length": {"value": 0.0960031, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d6d87a15-b966-4e10-bace-11ae16b68c35", "name": "l(r:p1rdt465-p1rdt478)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a94f7afe-e8b0-4b24-8196-6b05e98c3830"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eba354c-f4bf-4c49-a8ad-998ab9489e5a"}}}], "length": {"value": 0.0203603, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "485b7ea4-6076-4866-bc63-7950ab5f04be", "name": "l(r:p1rdt465-p1rdt488)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fa474a3-1d6b-454b-9170-6a8d13789c43"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a94f7afe-e8b0-4b24-8196-6b05e98c3830"}}}], "length": {"value": 0.148866, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "c56be5eb-6989-4184-86ff-3b60dff1d2be", "name": "l(r:p1rdt463-p1rdt488)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7637cfdb-6a14-4313-95d4-e25beba178f3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fa474a3-1d6b-454b-9170-6a8d13789c43"}}}], "length": {"value": 0.0269677, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "85776a35-68a0-48b2-b32c-4fcf63f765bf", "name": "l(r:p1rdt463-p1rdt82)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7627cbc6-c54a-432b-8cba-59e448f6d45a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7637cfdb-6a14-4313-95d4-e25beba178f3"}}}], "length": {"value": 0.14966800000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "95bc8f10-ed30-43b9-88b7-71e259b40cd0", "name": "l(r:p1rdt78-p1rdt82)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36bfd1f1-80ca-4b7d-a68b-9aa77ceff96e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7627cbc6-c54a-432b-8cba-59e448f6d45a"}}}], "length": {"value": 0.0637409, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "9c2f5d3e-aed7-46b7-a9db-8653f9ca9dab", "name": "l(r:p1rdt78-p1rdt85)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fc415bc-f457-4e9f-bbd4-783a71b67ad6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36bfd1f1-80ca-4b7d-a68b-9aa77ceff96e"}}}], "length": {"value": 0.0375885, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "6a1cad6b-2cac-431d-af4c-21b2a59172a9", "name": "l(r:p1rdt81-p1rdt85)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "063e25be-2abb-49ae-b459-ddd08ba93bb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fc415bc-f457-4e9f-bbd4-783a71b67ad6"}}}], "length": {"value": 0.0219108, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "90683555-cb96-4ee2-8b94-86a64832f1b8", "name": "l(r:p1rdt79-p1rdt81)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b32c9763-ddff-435b-a28c-8f65111c6cb2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "063e25be-2abb-49ae-b459-ddd08ba93bb3"}}}], "length": {"value": 0.0220447, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "372cf68c-8148-4394-a412-526fb4273f82", "name": "l(r:p1rdt76-p1rdt79)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfbb212a-9882-4468-86ac-578c93fde1d8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b32c9763-ddff-435b-a28c-8f65111c6cb2"}}}], "length": {"value": 0.0442698, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "24ae7f1a-6a8a-4a84-aed9-7438bb1bec6e", "name": "l(r:p1rdt31-p1rdt76)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7c543753-fa26-41df-b7a6-3664395c0d45"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfbb212a-9882-4468-86ac-578c93fde1d8"}}}], "length": {"value": 0.117156, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f53f5aae-c274-43c4-b7af-d3041298dfff", "name": "l(r:p1rdt31-p1rdt36)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8dcdfef-b40e-4f1c-9b7c-e84846f68c5a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7c543753-fa26-41df-b7a6-3664395c0d45"}}}], "length": {"value": 0.088569, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "e93867c8-7f0e-49a3-8db2-3f7907cc4bff", "name": "l(r:p1rdt32-p1rdt36)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "834e959c-8ee6-4fff-b1fc-54c20fc0f20b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8dcdfef-b40e-4f1c-9b7c-e84846f68c5a"}}}], "length": {"value": 0.10601200000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "5231e2a7-fda4-48de-a8e5-a4f8a504694d", "name": "l(r:p1rdt234-p1rdt32)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80331f15-8b31-454c-a289-49cb79923252"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "834e959c-8ee6-4fff-b1fc-54c20fc0f20b"}}}], "length": {"value": 0.0518824, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "198b7f01-439d-4fea-bb64-8e615b1d0219", "name": "l(r:p1rdt233-p1rdt485)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f5ed5d5-93fc-4f3c-a78b-df7019863b67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "445f61a4-8045-4558-a3c1-bb44336737ec"}}}], "length": {"value": 0.123436, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "c8e84a6d-4476-4110-8a87-5bff5dfd82d6", "name": "l(r:p1rdt233-p1rdt236)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "190d6c51-94b6-462e-8fee-cce57f1ab66d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f5ed5d5-93fc-4f3c-a78b-df7019863b67"}}}], "length": {"value": 0.0731224, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "ac72dac2-d88d-478e-9c53-c5d07d08999e", "name": "l(r:p1rdt234-p1rdt236)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80331f15-8b31-454c-a289-49cb79923252"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "190d6c51-94b6-462e-8fee-cce57f1ab66d"}}}], "length": {"value": 0.175361, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "bff96efe-7ad7-4117-8d5e-ed34b5e1b0d0", "name": "l(r:p1rdt234-p1rdt235)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14b85850-d83e-4a5e-83c3-ccb485bb85aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80331f15-8b31-454c-a289-49cb79923252"}}}], "length": {"value": 0.10401900000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "4b67aeb5-bf41-404b-b4d6-ed2773d5f4a9", "name": "l(r:p1rdt235-p1rdt30)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fa95a19-0e0a-49b3-bb86-7103fbaa4110"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14b85850-d83e-4a5e-83c3-ccb485bb85aa"}}}], "length": {"value": 0.07237510000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "9e0dc484-5292-4398-b046-2bb0b8595c8c", "name": "l(r:p1rdt30-p1rdt35)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "edc22f66-e919-448e-b990-76033c281d43"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fa95a19-0e0a-49b3-bb86-7103fbaa4110"}}}], "length": {"value": 0.108408, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "57e13003-4b6c-451f-b816-8653b0a58096", "name": "l(r:p1rdt35-p1rdt84)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e9f4b13-5fb5-46b2-9258-83582d47d61a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "edc22f66-e919-448e-b990-76033c281d43"}}}], "length": {"value": 0.0706611, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "30145750-aaff-48a3-b83b-9b27874f2bc3", "name": "l(r:p1rdt33-p1rdt84)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f55e4012-a11d-4883-baac-9c013aff6058"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e9f4b13-5fb5-46b2-9258-83582d47d61a"}}}], "length": {"value": 0.08205580000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f055d7d6-9d6d-4aa0-955c-8987e1322223", "name": "l(r:p1rdt33-p1rdt39)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a01c83d1-4adb-4b2a-8de3-441d7c1dd054"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f55e4012-a11d-4883-baac-9c013aff6058"}}}], "length": {"value": 0.0532669, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "ab5f4002-be54-4c6e-8532-bd6c2fa76205", "name": "l(r:p1rdt39-p1rdt73)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc531967-1a7b-4424-83ee-e1131c6fd94c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a01c83d1-4adb-4b2a-8de3-441d7c1dd054"}}}], "length": {"value": 0.0177535, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "664a630b-6756-439e-a71a-12b73095c4bf", "name": "l(r:p1rdt73-p1rdt75)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "510ea93c-7dd1-4fa3-ba3f-6c362856c7c1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc531967-1a7b-4424-83ee-e1131c6fd94c"}}}], "length": {"value": 0.0510053, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "17c999b3-2206-4299-a8c6-d725bd804b3c", "name": "l(r:p1rdt75-p1rdt83)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aa0b7c2-9d55-4faf-8778-76a6f23bcf3e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "510ea93c-7dd1-4fa3-ba3f-6c362856c7c1"}}}], "length": {"value": 0.0608389, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "a03c0ec0-e778-49bd-babf-57f483e5f78d", "name": "l(r:p1rdt80-p1rdt83)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b03f8e29-a5b2-4bed-b68c-219276674b6a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aa0b7c2-9d55-4faf-8778-76a6f23bcf3e"}}}], "length": {"value": 0.10093, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "8435eda2-aebc-4043-8961-853e603285bf", "name": "l(r:p1rdt263-p1rdt80)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e26e5dc-8c98-4fcd-b125-3265eb00f3f2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b03f8e29-a5b2-4bed-b68c-219276674b6a"}}}], "length": {"value": 0.7842920000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "b8f9d0e5-0e06-4d03-a44d-6fbdf10da8a4", "name": "l(r:p1rdt263-p1rdt277)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "add5e39f-f02e-4a61-a156-d5721cec25d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e26e5dc-8c98-4fcd-b125-3265eb00f3f2"}}}], "length": {"value": 0.731992, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "2f9e0bfb-0ba5-4693-8dbb-8500785d1fa7", "name": "l(r:p1rdt276-p1rdt277)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "186ffdfe-2346-4218-bd6b-b813ea6b3b62"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "add5e39f-f02e-4a61-a156-d5721cec25d5"}}}], "length": {"value": 0.376236, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "095deedb-f5aa-4b88-8ec2-fa9270de8eee", "name": "l(r:p1rdt44-p1rdt69)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9396562e-4f87-4e04-b248-502b851fe19e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1bf1493-fb0d-40b4-8953-42e851a128d1"}}}], "length": {"value": 0.096072, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "16c1200d-d591-4bd8-aa0f-4d52544f6dca", "name": "l(r:p1rdt44-p1rdt69)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1bf1493-fb0d-40b4-8953-42e851a128d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d9ee2ff-e2bc-4d76-b173-5ba5cc48c9b3"}}}], "length": {"value": 0.103033, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d2e808c0-fed6-463f-887f-0e7be56eabd4", "name": "l(r:p1rdt41-p1rdt69)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5b5b3ae-f657-4fd4-a311-ab1dbe9d749e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9396562e-4f87-4e04-b248-502b851fe19e"}}}], "length": {"value": 0.0379066, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "ccf449d9-5f73-457c-ad76-1fc3f639c69d", "name": "l(r:p1rdt41-p1rdt54)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a898f4c-f522-4e69-be4a-e935e339e011"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5b5b3ae-f657-4fd4-a311-ab1dbe9d749e"}}}], "length": {"value": 0.0700668, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "0bf9bcaf-d009-493b-b258-a20b48a817ea", "name": "l(r:p1rdt42-p1rdt54)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a778171c-22a1-4320-9e3c-43888d734e34"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a898f4c-f522-4e69-be4a-e935e339e011"}}}], "length": {"value": 0.0819124, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "fe298b54-0758-4c2f-937f-b4e520788b5d", "name": "l(r:p1rdt42-p1rdt45)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29a79372-9c75-4a9c-81df-a7491b87e58a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a778171c-22a1-4320-9e3c-43888d734e34"}}}], "length": {"value": 0.109393, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "7752518c-dbd5-4bcf-98ba-736e959ee9fd", "name": "l(r:p1rdt150-p1rdt45)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12451cbc-eb14-4814-b274-12eb2241c78a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "666bb367-692a-4127-8f77-d86d651768a1"}}}], "length": {"value": 0.181242, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "1af5f53b-c460-4041-bb80-361236411275", "name": "l(r:p1rdt150-p1rdt45)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "666bb367-692a-4127-8f77-d86d651768a1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29a79372-9c75-4a9c-81df-a7491b87e58a"}}}], "length": {"value": 1.27197, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "9f74db70-41c8-4e3a-954c-bbda4ce07e86", "name": "l(r:p1rdt150-p1rdt260)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba0ef4a3-43ba-469b-8ce8-ca7a5a984071"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e885b3e5-18fb-4454-b8e7-d82b4c72f6e8"}}}], "length": {"value": 0.105488, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "43084528-6f58-47a7-8115-80e604d313d3", "name": "l(r:p1rdt150-p1rdt260)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e885b3e5-18fb-4454-b8e7-d82b4c72f6e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12451cbc-eb14-4814-b274-12eb2241c78a"}}}], "length": {"value": 0.49255100000000007, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "19fa5caf-ed6f-48b1-aef3-26ccfa1abc3b", "name": "l(r:p1rdt260-p1rdt279)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "153bb615-5ee5-4eec-bcf7-94ea0098aeb6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba0ef4a3-43ba-469b-8ce8-ca7a5a984071"}}}], "length": {"value": 0.693281, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "b5f6404e-7ee0-44ba-83b2-4d2a8b780d6d", "name": "l(r:p1rdt276-p1rdt279)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7140d97e-416e-47ec-9f86-46ad6f9abece"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "153bb615-5ee5-4eec-bcf7-94ea0098aeb6"}}}], "length": {"value": 0.296948, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "a22eecf7-0b6c-4b67-b1b6-ef07cf773782", "name": "l(r:p1rdt237-p1rdt276)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3ca9bee-26b0-4ef4-8555-6494ffdd6a17"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "767b59ef-ecd9-4b17-8233-2033a02b2971"}}}], "length": {"value": 0.558882, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "3aa27888-757a-4ade-a479-17348bb56293", "name": "l(r:p1rdt237-p1rdt276)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "767b59ef-ecd9-4b17-8233-2033a02b2971"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "186ffdfe-2346-4218-bd6b-b813ea6b3b62"}}}], "length": {"value": 0.599014, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "3494f392-4b57-4668-b618-de109c41f74b", "name": "l(r:p1rdt237-p1rdt445)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11571d26-573f-49f7-99fd-828dde97afd8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8c8b8f8-7a41-4d16-b509-2d7c7af9509d"}}}], "length": {"value": 0.477235, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "23768e60-635b-4d3f-be8d-50fde874d64a", "name": "l(r:p1rdt438-p1rdt445)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10620dcc-049c-4417-b4ac-922a56c0d4a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11571d26-573f-49f7-99fd-828dde97afd8"}}}], "length": {"value": 0.109204, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "418c0e4f-5a25-445f-91f1-8a7745ad0c0b", "name": "l(r:p1rdt438-p1rdt446)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3dfe357-889d-42e0-a59a-821c9f843456"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10620dcc-049c-4417-b4ac-922a56c0d4a2"}}}], "length": {"value": 0.05910800000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "0e0c3e54-806e-4c0f-9753-303f0f99e48d", "name": "l(r:p1rdt28-p1rdt446)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e71eb2d5-cd10-498d-b9eb-ae337b2f8af6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3dfe357-889d-42e0-a59a-821c9f843456"}}}], "length": {"value": 2.20796, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d440b633-33ea-4a79-a563-f95e7e886d44", "name": "l(r:p1rdt28-p1rdt29)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b238dc5-7d8e-4b2d-8449-4dc212d7d227"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e71eb2d5-cd10-498d-b9eb-ae337b2f8af6"}}}], "length": {"value": 0.24769, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "60bac6f6-9fdd-4815-92c7-20ba11b7d04a", "name": "l(r:p1rdt29-p1rdt335)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b07c4a6-39a7-4521-bce7-3f1ca0ff4a66"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b238dc5-7d8e-4b2d-8449-4dc212d7d227"}}}], "length": {"value": 0.899533, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "ad61cfe0-a656-43cd-97b6-04704f1d3e5b", "name": "l(r:p1rdt335-p1rdt419)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2efeaf5-2055-4718-a064-7c5e00b7d87d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b07c4a6-39a7-4521-bce7-3f1ca0ff4a66"}}}], "length": {"value": 1.90653, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "e66e4d18-0d3a-4652-bd28-391e4e42b5ca", "name": "l(r:p1rdt419-p1rdt420)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4cf05060-0a39-49a9-a761-79fb136e2965"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81cfd2a2-295c-4b73-abba-05ffee810523"}}}], "length": {"value": 0.238058, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "e475a674-9e0e-438b-956a-b0c948b066b6", "name": "l(r:p1rdt420-p1rdt8167)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eb3d4eb-71fc-46f3-b588-d223568c411c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4cf05060-0a39-49a9-a761-79fb136e2965"}}}], "length": {"value": 0.4863970000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "cc58970e-64bc-4597-914e-37cb30e8ffc9", "name": "l(r:p1rdt8167-p1rdt8180)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c93a476-4ad5-41cd-a07b-e2ccc9ef2c3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eb3d4eb-71fc-46f3-b588-d223568c411c"}}}], "length": {"value": 0.163613, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "62e99707-ce49-47b4-a983-1959eeb7a76e", "name": "l(r:p1rdt8169-p1rdt8180)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c93a476-4ad5-41cd-a07b-e2ccc9ef2c3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6bdb2cf-9373-4d56-a5f9-cb8fa9c67e55"}}}], "length": {"value": 0.222344, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "a780ffe2-7718-4b83-b86a-e0fe3fb9d703", "name": "l(r:p1rdt8174-p1rdt8180)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "498a07ee-e12b-459a-a01f-f663a4a8428a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c93a476-4ad5-41cd-a07b-e2ccc9ef2c3b"}}}], "length": {"value": 0.527921, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "6617344b-9ba8-444d-bb97-2a58fedb9fbd", "name": "l(r:p1rdt8174-p1rdt8195)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8997dae6-8970-4762-98e9-0617375633d6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b0f9433-e0a3-458a-8687-c9cf38d0bbb3"}}}], "length": {"value": 0.115815, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "84d5b120-0d32-4f1b-a36d-b5c13c2111a5", "name": "l(r:p1rdt7757-p1rdt8195)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "081feb5c-d5d5-405e-85d4-f1dd0916fc3d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8997dae6-8970-4762-98e9-0617375633d6"}}}], "length": {"value": 0.279303, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "9ddeb1c5-3ca3-4e2d-9c80-477ec8adb6be", "name": "l(r:p1rdt5560-p1rdt7757)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68117bef-16c5-40c9-9356-76ef5c056650"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b64b7bd6-06e4-45f7-b987-efc7d09b91f8"}}}], "length": {"value": 0.322295, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "1e9bf254-9c79-4ea5-8fad-7bda32329ae5", "name": "l(r:p1rdt5560-p1rdt7757)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b64b7bd6-06e4-45f7-b987-efc7d09b91f8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "081feb5c-d5d5-405e-85d4-f1dd0916fc3d"}}}], "length": {"value": 0.349419, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "15fcd358-cd82-4f30-b9a7-7166929792fe", "name": "l(r:p1rdt5560-p1rdt5564)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8444c9ea-ff7a-4b0a-9ea6-9c18770565cb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68117bef-16c5-40c9-9356-76ef5c056650"}}}], "length": {"value": 0.08906480000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "224b5f84-1923-4354-9d26-d73c5031bd42", "name": "l(r:p1rdt5563-p1rdt5564)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad24f98d-f022-4e62-b80b-426052810759"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8444c9ea-ff7a-4b0a-9ea6-9c18770565cb"}}}], "length": {"value": 0.0604798, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "33a61b6a-9e2b-42e9-ad56-90f1398207e6", "name": "l(r:p1rdt5557-p1rdt5563)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c94489ed-4399-4dab-bab6-02b79f240f63"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fbc31b75-f942-4bae-8712-f1666d8b7f26"}}}], "length": {"value": 0.0599682, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "20b4ef91-8e73-4465-8325-4d24a3b897d5", "name": "l(r:p1rdt5557-p1rdt5565)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "efe7243f-340b-4114-be7c-f7494e78384f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bfe92e2e-285d-4c58-8e0b-a462dd73fa41"}}}], "length": {"value": 0.058444, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "6efab38c-c3e9-4312-b685-21a2d96b021e", "name": "l(r:p1rdt5561-p1rdt5565)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8bd0860f-2b3e-4c90-a571-cfc6aa649e5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bebca5d7-2d4f-4655-a965-9faafd7a8125"}}}], "length": {"value": 0.047072, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "029915e5-6ffa-4e8a-992f-299338154773", "name": "l(r:p1rdt5551-p1rdt5561)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27ab530f-a58e-4113-80f6-63f768910204"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf97a458-469e-4609-bb33-97454e7c2b68"}}}], "length": {"value": 0.0283038, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "f198382a-0a0f-4e03-9ae9-b2efa019c2ca", "name": "l(r:p1rdt5548-p1rdt5551)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d447cf8-7b2b-45f1-8084-6fe4897e1853"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ec70f12-a676-48cd-b626-34f8d7f6a5bf"}}}], "length": {"value": 0.0368985, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "a4b33341-bd57-4d7b-b4aa-f10eebfda207", "name": "l(r:p1rdt5548-p1rdt5566)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10f43169-4b4b-4dbe-8f09-af72d427d6c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23163dba-070c-435c-bb90-77be7ded002a"}}}], "length": {"value": 0.0390774, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "40c04881-ef90-4bbb-9776-4086b7596654", "name": "l(r:p1rdt5566-p1rdt5574)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf619f04-1fa5-4be7-8a76-669b79436d3e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c264e6de-a898-421d-a2fe-ce6548aa477e"}}}], "length": {"value": 0.00976661, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "3d33cc3f-87f4-4ed0-91cc-87931b9584c8", "name": "l(r:p1rdt5574-p1rdt8138)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17b633c6-214d-4428-bded-df737f50ffb6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c8fd701-7842-49c1-b630-7ae1ad49739f"}}}], "length": {"value": 0.295682, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "596de436-8b70-4b86-90d6-c950c609a1a1", "name": "l(r:p1rdt5574-p1rdt8138)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c8fd701-7842-49c1-b630-7ae1ad49739f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9906676-e9b9-4d51-b1c2-a6b6fe187faa"}}}], "length": {"value": 0.00299767, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "1e2f5da7-2523-420f-9a3f-8207dba32215", "name": "l(r:p1rdt6488-p1rdt8138)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63b2f1e6-5e15-4433-85ee-ff7bb7218b96"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "548ba541-a511-486c-876c-c841a6e482af"}}}], "length": {"value": 0.512556, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "05321a30-75f0-40c2-b4b8-86477a6638ba", "name": "l(r:p1rdt6488-p1rdt8138)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "548ba541-a511-486c-876c-c841a6e482af"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17b633c6-214d-4428-bded-df737f50ffb6"}}}], "length": {"value": 1.64392, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "0aea12b8-2186-4836-85d6-b58d4342e6b6", "name": "l(r:p1rdt6488-p1rhs7_1247)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ed5e3889-e8c8-4215-adb8-9880f8937da5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63b2f1e6-5e15-4433-85ee-ff7bb7218b96"}}}], "length": {"value": 0.640605, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "56c3525d-82f8-42be-a65c-cf7759d85f2d", "name": "l(r:p1rdt5551lv-p1rlv11506)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9dec144-ef2e-44fe-990a-c9d70b740410"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "82988650-787d-41de-bca7-4f3c08ccad15"}}}], "length": {"value": 0.0327608, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "5c2ec73d-3368-4c1c-9ef2-795598c70ec1", "name": "l(r:p1rdt5565lv-p1rlv11522)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60dc1291-a843-4abf-bfc6-ff8afc8c0b98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "176b348f-9ecf-4a82-bdf9-f2e5d5a07af7"}}}], "length": {"value": 0.05525650000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "6dacb7f0-677a-488e-9ecc-948c66479101", "name": "l(r:p1rdt5563lv-p1rlv11520)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a150dd3-61a4-4df9-90e2-6c72f80af819"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22054033-4e69-41b0-b321-a4d086d20574"}}}], "length": {"value": 0.0488534, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "96e610fa-0320-4fdb-a89f-9dc0244a5f46", "name": "l(r:p1rdt252lv-p1rlv440)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5fd6466-e740-4f06-a842-798195d62154"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a23f97bc-e7ef-4f64-9e64-314f4a4e17d8"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "3281c6b4-cd7b-405e-b82d-01608de0b3bf", "name": "padswitch(r:p1rdt5551-p1rdt5568)p1r_14627", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "514ad102-b590-4ad8-a258-2b6fa8dcbeb1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8aa126c-9b2b-4ae0-a4fc-36d4201762a0"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "6ba5defb-3101-4ef8-8d06-36719f7dad94"}}}}, {"uuid": "bf6157a4-7aa1-4ed3-b5bb-c658cc930d54", "name": "padswitch(r:p1rdt5551-p1rdt5568)p1r_14628", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64aba8d5-1dd3-4741-a8ba-26801e275ba8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c83b6ee-20fc-4ca0-a778-44735283afd5"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "b477d9d0-158a-46f2-92c2-f5870d9f433b", "name": "padswitch(r:p1rdt5548-p1rdt5577)p1r_14631", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25ee6008-ddbc-4e7b-8a57-ff38c16368a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c49b671-0b2b-43c9-bcb5-21c7b7e716ce"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "fa89ef5e-f965-457f-a553-4831f61b03c7"}}}}, {"uuid": "53cb1567-da04-45d8-9bf4-0dd5a812110d", "name": "padswitch(r:p1rdt5548-p1rdt5577)p1r_14632", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fead5749-3ba7-4ead-a604-e8adbd18f8c2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1c8b424-4509-4fd2-93e2-4fd54f6cf49a"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "3baa725a-9b39-45f8-86af-c6afda2cdf9f"}}}}, {"uuid": "f1d7385c-f334-4abd-acbc-268a6e1aa5fb", "name": "padswitch(r:p1rdt5557-p1rdt5563)p1r_14619", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cca8918c-30e6-4619-a5e0-8c0d3451f9c4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c94489ed-4399-4dab-bab6-02b79f240f63"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "2f835dde-37f4-47dd-ab96-214dd85d3c9e", "name": "padswitch(r:p1rdt5557-p1rdt5563)p1r_14620", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fbc31b75-f942-4bae-8712-f1666d8b7f26"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad24f98d-f022-4e62-b80b-426052810759"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "2419ddcd-627b-4faa-9878-65d4baf7d064"}}}}, {"uuid": "89b15386-98d4-4c15-bfd2-f82b5eea6b2a", "name": "padswitch(r:p1rdt5557-p1rdt5565)p1r_14621", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5e479d3-aae0-47b8-b707-bad1191df1e7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "efe7243f-340b-4114-be7c-f7494e78384f"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "ab2720f4-bdaa-4e93-a718-9d3398ce76a4"}}}}, {"uuid": "e2976123-591b-407f-8e3f-879e531049f6", "name": "padswitch(r:p1rdt5557-p1rdt5565)p1r_14622", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bfe92e2e-285d-4c58-8e0b-a462dd73fa41"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cca8918c-30e6-4619-a5e0-8c0d3451f9c4"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "bb21ddca-c238-4ca4-9574-9f21459c4f5a", "name": "padswitch(r:p1rdt5561-p1rdt5565)p1r_14623", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "756f6cd8-301b-4fac-b414-d72853616c6e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8bd0860f-2b3e-4c90-a571-cfc6aa649e5b"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "f58eeeef-b7c0-4252-b089-8de5183abc7c", "name": "padswitch(r:p1rdt5561-p1rdt5565)p1r_14624", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bebca5d7-2d4f-4655-a965-9faafd7a8125"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5e479d3-aae0-47b8-b707-bad1191df1e7"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "74d1d12a-803b-48eb-8e5b-0df008dc80b1", "name": "padswitch(r:p1rdt5551-p1rdt5561)p1r_14625", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f7fed4f-197e-4a79-97e5-df595377736b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27ab530f-a58e-4113-80f6-63f768910204"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "772c9103-cfcf-4ab9-ac69-f02423fe009f", "name": "padswitch(r:p1rdt5551-p1rdt5561)p1r_14626", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf97a458-469e-4609-bb33-97454e7c2b68"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "756f6cd8-301b-4fac-b414-d72853616c6e"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "278a53ba-f477-4f46-be13-b05dcff80778", "name": "padswitch(r:p1rdt5548-p1rdt5551)p1r_14629", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bf1b63d-fbce-42f8-9948-2e09bfa67409"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d447cf8-7b2b-45f1-8084-6fe4897e1853"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "c01372a2-4296-4877-a1f3-dd8c06d37f74"}}}}, {"uuid": "020e3a1d-353f-48a4-a297-a32861f78a5c", "name": "padswitch(r:p1rdt5548-p1rdt5551)p1r_14630", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ec70f12-a676-48cd-b626-34f8d7f6a5bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f7fed4f-197e-4a79-97e5-df595377736b"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "75397079-8541-4fed-9f2e-283746d35392", "name": "padswitch(r:p1rdt5548-p1rdt5566)p1r_14633", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fed9557-b170-4817-8bd8-efc3b9f7c982"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10f43169-4b4b-4dbe-8f09-af72d427d6c7"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4900e609-ebb1-44db-852b-602449095f15"}}}}, {"uuid": "9fbe0ee9-ae7d-4233-af14-ea12e83dc720", "name": "padswitch(r:p1rdt5548-p1rdt5566)p1r_14634", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23163dba-070c-435c-bb90-77be7ded002a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bf1b63d-fbce-42f8-9948-2e09bfa67409"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "d4fd35e4-7997-430a-854e-c1cdde29c7cc", "name": "padswitch(r:p1rdt5566-p1rdt5574)p1r_14635", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9906676-e9b9-4d51-b1c2-a6b6fe187faa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf619f04-1fa5-4be7-8a76-669b79436d3e"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "f3caa620-fb40-4165-abf4-46f624ae5a85", "name": "padswitch(r:p1rdt5566-p1rdt5574)p1r_14636", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c264e6de-a898-421d-a2fe-ce6548aa477e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fed9557-b170-4817-8bd8-efc3b9f7c982"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "8e708baa-3ad1-4899-8c29-fc507efdc551", "name": "fuse(r:p1rdt31-p1rdt38)p1r_16627", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7c543753-fa26-41df-b7a6-3664395c0d45"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "668d32be-c07a-4387-86a5-e9754af11e9c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "5ef87d33-a0f9-4b56-9457-0d7cb679088c", "name": "fuse(r:p1rdt210-p1rdt44)p1r_16628", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d9ee2ff-e2bc-4d76-b173-5ba5cc48c9b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1be5e34-ad5e-4c78-8067-8e0194c661a4"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "251fa307-5e1e-4ffa-a841-ff333862a949", "name": "fuse(r:p1rdt259-p1rdt44)p1r_16629", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d9ee2ff-e2bc-4d76-b173-5ba5cc48c9b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0b5743e-c3fd-49c7-879e-9be7d00c480f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "105be1c0-9f28-4814-ab44-267fbb4f0af7", "name": "fuse(r:p1rdt58-p1rdt69)p1r_16631", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9396562e-4f87-4e04-b248-502b851fe19e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7238345a-1fc7-4f3f-bc8b-88cf7582c75c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "c452d159-ea97-4544-ab4a-93d0e7ce8631", "name": "fuse(r:p1rdt37-p1rdt80)p1r_16632", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b03f8e29-a5b2-4bed-b68c-219276674b6a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a2b529c9-4695-42f3-a0e3-69bbb34ff285"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "da4bb223-04fc-4e5d-b2db-f16866497bb6", "name": "fuse(r:p1rdt74-p1rdt85)p1r_16633", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fc415bc-f457-4e9f-bbd4-783a71b67ad6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b82a9a2-b1d1-44eb-a451-946643ef613d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "58221277-9ee4-4071-8967-a1d0bdcbbf92", "name": "fuse(r:p1rdt150-p1rdt71)p1r_16651", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12451cbc-eb14-4814-b274-12eb2241c78a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eab6b8c5-ee7a-4779-b5eb-5205dbe5253c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "74603d74-9f0d-4842-b655-cfdee489dad0", "name": "fuse(r:p1rdt251-p1rdt254)p1r_16679", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b801037a-e1bb-4c5c-8d18-ed285c8c1d3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9c899bc-796a-4e92-88db-6aa11f8777cb"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "25c5e70e-dd57-4030-b431-72effcf942e6", "name": "fuse(r:p1rdt252-p1rdt385)p1r_16680", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69b2ee46-ab5f-48c8-a26b-170ed2b57fcb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22179eaa-fd19-4619-8b31-52bcb36ec683"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770"}}}}, {"uuid": "af70abad-e2d2-466e-ac06-19c43f7ce09a", "name": "fuse(r:p1rdt261-p1rdt277)p1r_16684", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "add5e39f-f02e-4a61-a156-d5721cec25d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bbe3ac37-aca0-47fd-ac5d-be390cad10ab"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "5cb48d44-c6a0-4b2a-ae95-38168b6ed9e6", "name": "fuse(r:p1rdt279-p1rdt89)p1r_16685", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "153bb615-5ee5-4eec-bcf7-94ea0098aeb6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "232adbbb-2715-44be-8db5-ee062ebf4e46"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "ae0efabc-30d4-4b0b-87f1-14de9ef567fc", "name": "fuse(r:p1rdt335-p1rdt376)p1r_16692", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b07c4a6-39a7-4521-bce7-3f1ca0ff4a66"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0de112ae-d04a-4673-98af-0699e4890429"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "804bf703-8117-4553-b55c-90b0e0138f28", "name": "fuse(r:p1rdt415-p1rdt419)p1r_16706", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81cfd2a2-295c-4b73-abba-05ffee810523"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19116f3c-29ae-4819-ba72-dd0f8afa5078"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "cc0d8f4f-cb74-41bf-915f-657a26c4dce0", "name": "fuse(r:p1rdt456-p1rdt465)p1r_16710", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a94f7afe-e8b0-4b24-8196-6b05e98c3830"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b092ee09-4c5e-46b5-8ec2-51f99254c220"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "9d67edf0-3af2-46a6-b5a7-af017e3a23be", "name": "fuse(r:p1rdt458-p1rdt468)p1r_16711", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a180b972-cf0e-4a2e-9bcf-a0ad90bb3d83"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04fc215c-7f3e-45e1-a49c-727b0fcdae93"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770"}}}}, {"uuid": "e812226f-f357-4c18-96e8-9949554baf21", "name": "fuse(r:p1rdt468-p1rdt474)p1r_16712", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a180b972-cf0e-4a2e-9bcf-a0ad90bb3d83"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5814195b-dd60-4a1e-9af6-b9b84fa4c0c7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "9860b763-07dc-4e8d-8870-1afd3a7f37e2", "name": "fuse(r:p1rdt466-p1rdt478)p1r_16713", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eba354c-f4bf-4c49-a8ad-998ab9489e5a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64ba6716-89f9-49a4-9793-ba80ae41bcd0"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "da8c1709-80de-4678-8309-269d2f230e38", "name": "fuse(r:p1rdt482-p1rdt485)p1r_16714", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "445f61a4-8045-4558-a3c1-bb44336737ec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4064b6c-40b4-418b-95ab-4f9bb0363b14"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770"}}}}, {"uuid": "c04ff227-206a-442c-a266-475342372f3b", "name": "fuse(r:p1rdt483-p1rdt485)p1r_16715", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "445f61a4-8045-4558-a3c1-bb44336737ec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d899b807-b194-4f65-bad5-a39e8bc61906"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "2b29065b-ab29-4a29-992e-6fa020baefb0", "name": "fuse(r:p1rdt5548-p1rdt5577)p1r_17662", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bf1b63d-fbce-42f8-9948-2e09bfa67409"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25ee6008-ddbc-4e7b-8a57-ff38c16368a2"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "73f75b89-55b4-4a16-9fa1-8771daf3d5be"}}}}, {"uuid": "ac5b78b4-1db7-4049-8ac8-190123ae26d7", "name": "fuse(r:p1rdt5551-p1rdt5568)p1r_17664", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f7fed4f-197e-4a79-97e5-df595377736b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "514ad102-b590-4ad8-a258-2b6fa8dcbeb1"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "861d64ae-aba6-4135-a3ca-f177438722a2"}}}}, {"uuid": "6de2926c-cdd7-4dbe-954c-e5e73d440add", "name": "fuse(r:p1rdt5560-p1rdt9055)p1r_17668", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68117bef-16c5-40c9-9356-76ef5c056650"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30adfcd5-405b-47ea-be54-55c5a47c835f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "b77c5f87-769c-4ad7-b6b5-9fbe48d98a9e", "name": "fuse(r:p1rdt6488-p1rdt7300)p1r_17851", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63b2f1e6-5e15-4433-85ee-ff7bb7218b96"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47f8ed28-4bff-47d9-8ffe-4509e9c5b7fc"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "3228c925-05c0-4c64-b9fc-c95e6716280b", "name": "fuse(r:p1rdt7757-p1rdt7795)p1r_18078", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "081feb5c-d5d5-405e-85d4-f1dd0916fc3d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0cd22d3e-1e2a-4a99-9967-b9df95837915"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "5bbe221f-b4a5-48b0-807d-e4b8038385f1", "name": "fuse(r:p1rdt8111-p1rdt8138)p1r_18142", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17b633c6-214d-4428-bded-df737f50ffb6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9929e0d4-3e33-4f5f-b718-6a629cc52242"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "1f205dc8-03e2-4638-9e38-39bda752ee14", "name": "fuse(r:p1rdt5098-p1rdt8169)p1r_18150", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6bdb2cf-9373-4d56-a5f9-cb8fa9c67e55"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb3d775d-8d92-498b-989c-387278ec8e9e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "7a9f88b5-9266-4dc3-94d4-4b1fd3397487", "name": "fuse(r:p1rdt6266-p1rdt8174)p1r_18152", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b0f9433-e0a3-458a-8687-c9cf38d0bbb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d07105ef-1ba3-4775-aeb4-650b5ea8736e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770"}}}}, {"uuid": "d30f8def-15f6-47be-ab3f-8814ccb37121", "name": "fuse(r:p1rdt8180-p1rdt8201)p1r_18154", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c93a476-4ad5-41cd-a07b-e2ccc9ef2c3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63928702-c44a-4e83-9cca-7ce77bdbd2b3"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "6b0a6718-181b-4c20-9dc3-45257942ad04", "name": "goab_disswitch(r:p1rdt335-p1rdt419)p1r_20734", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81cfd2a2-295c-4b73-abba-05ffee810523"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2efeaf5-2055-4718-a064-7c5e00b7d87d"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "2419ddcd-627b-4faa-9878-65d4baf7d064"}}}}, {"uuid": "a8dbe250-f335-4a33-8967-d9144ec88082", "name": "goab_disswitch(r:p1rdt276-p1rdt279)p1r_20887", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "186ffdfe-2346-4218-bd6b-b813ea6b3b62"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7140d97e-416e-47ec-9f86-46ad6f9abece"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "466a17b2-2a29-4496-8652-610b208f7f1b", "name": "disswitch(r:p1rdt181-p1rdt297)p1r_20911", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d32493ec-06be-48ef-959e-779c79c507a3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2fddf29e-6eef-4c60-ad8b-4580440973b3"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "7351fbec-02bf-4cbf-aea9-09a23aa2a9b8", "name": "goab_disswitch(r:p1rdt237-p1rdt276)p1r_20993", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8c8b8f8-7a41-4d16-b509-2d7c7af9509d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3ca9bee-26b0-4ef4-8555-6494ffdd6a17"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "2a5a5f0e-3473-4d3f-ac60-0c576781cacc", "name": "disswitch(r:p1rdt16790-p1rdt487)p1r_21007", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfb0d992-ab18-4f73-933e-a01ce73ef3b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d53ff9fd-2b16-4026-88fa-2c112d4949c5"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "e7ce538c-39a2-4585-8cd8-85cefb5001b7", "name": "disswitch(r:p1rdt16604-p1rdt257)p1r_21113", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fb307f7-3690-4931-999a-4daab4d8c9e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ef71bd7-4c82-4296-a6ac-64516ffe96c5"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "2d897f3c-bcb4-45c3-8f45-79a7882361d3", "name": "disswitch(r:p1rdt270-p1rdt298)p1r_21212", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a468f13-c61f-4c01-aa27-c75fb02030e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2c76250-d7ea-4da4-8008-dac1a579e974"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "05155e19-68bb-4b06-a90e-2af3c0f63384", "name": "recloser_disswitch(r:p1rdt8174-p1rdt8180)p1r_21285", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b0f9433-e0a3-458a-8687-c9cf38d0bbb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "498a07ee-e12b-459a-a01f-f663a4a8428a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "b8590a64-3624-43d1-8279-40a7928d98a9"}}}}, {"uuid": "4d2272d5-4fc9-48e9-84db-9b8f3f9f327a", "name": "disswitch(r:p1rdt383-p1rdt7300)p1r_21354", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05f14a3e-053e-4b65-b962-da7804b9e2c1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9240d01-bf5d-41ed-8c53-c1f04af1a236"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "c57b3c83-e7ed-4283-84e7-230a16052433", "name": "l(r:p1rdt383-p1rdt7300)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ac1506-77e9-4b90-ad3d-18be099063a9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16ace27f-f5fa-4fd1-840e-8cae55dbe1b2"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "40a26197-da2a-4e22-a50a-3922efd7762c"}}}}, {"uuid": "dfe3055b-071a-4b16-a1f5-8817c9563e7c", "name": "l(r:p1rdt383-p1rdt7300)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16ace27f-f5fa-4fd1-840e-8cae55dbe1b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d49257c8-f8eb-4024-9c02-461d18cdd3d5"}}}], "length": {"value": 2.9030580000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4bd7147d-d66a-4be7-afc9-1ac8815e7212", "name": "l(r:p1rdt181-p1rdt66)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24681ab1-3904-4509-85e6-d9bb1dba4c8e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6b5c947-b0c5-4e20-bd74-bf847bdacd30"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "40a26197-da2a-4e22-a50a-3922efd7762c"}}}}, {"uuid": "239c598c-522f-4509-8755-3e56148c7ce9", "name": "l(r:p1rdt181-p1rdt66)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6b5c947-b0c5-4e20-bd74-bf847bdacd30"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99615f32-0614-4c23-a1e1-b3e8e5688cce"}}}], "length": {"value": 1.8166859999999998, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c0340108-7ee4-45aa-91e0-afcce5d859a4", "name": "l(r:p1rdt181-p1rdt297)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d87f56c0-0a3f-4a94-8f60-1ece461290d0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "71abd5f1-ca61-4754-a2ef-7b5d4e635f99"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "40a26197-da2a-4e22-a50a-3922efd7762c"}}}}, {"uuid": "ef009cf0-e83d-4133-b85e-647ec7c82b7f", "name": "l(r:p1rdt181-p1rdt297)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "71abd5f1-ca61-4754-a2ef-7b5d4e635f99"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79d0fee6-369b-4f95-a2d2-cd05232652e3"}}}], "length": {"value": 4.570002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d448bbc0-7a67-4bb2-94aa-7d605ebab0df", "name": "l(r:p1rdt270-p1rdt298)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac7c613f-190c-493e-8e89-3ef48e8efdb9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0fad7ee-b65c-460c-94ca-fe9546a5b140"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "40a26197-da2a-4e22-a50a-3922efd7762c"}}}}, {"uuid": "c9722f40-a6c0-4a05-a737-bd2ff278c33d", "name": "l(r:p1rdt270-p1rdt298)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0fad7ee-b65c-460c-94ca-fe9546a5b140"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7eca59ac-01f1-40d7-a0ec-51f355285e01"}}}], "length": {"value": 2.6162099999999997, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3e4e6114-3df1-4523-b480-028a3f01d2e4", "name": "l(r:p1rdt16604-p1rdt257)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "282d8a89-8b14-476b-9e55-b310d8b9396d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8064f1d-11b7-4913-8344-175c1388be3e"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "40a26197-da2a-4e22-a50a-3922efd7762c"}}}}, {"uuid": "642f1479-fef3-4ab0-869d-276f7aaeca18", "name": "l(r:p1rdt16604-p1rdt257)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8064f1d-11b7-4913-8344-175c1388be3e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98a946e8-3c8a-49ec-be8a-5610c7fc596c"}}}], "length": {"value": 2.362599, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a7288c5c-c39d-4983-bd6a-e028ec000d5f", "name": "l(r:p1rdt7711-p1rhs7_1247)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1548dd91-bc3d-4a2c-903f-48e11159c558"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2131350-dc34-4d8d-8c9f-c29e25bc654c"}}}], "length": {"value": 2.34083, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "dfffd734-a5e2-42da-a25d-4360affa98b0", "name": "l(r:p1rdt7711lv-p1rlv16411)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64b60527-0853-4973-8d7a-78ba5e377799"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ed6276c-a57b-40be-a1f1-34aaaba0ac28"}}}], "length": {"value": 0.0104732, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "4eb8fe85-248b-4062-b84b-bd291bf09b51", "name": "l(r:p1rdt7711lv-p1rlv20414)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64b60527-0853-4973-8d7a-78ba5e377799"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0a92e79-0ca2-4a10-9050-9e8d7442b019"}}}], "length": {"value": 0.0104732, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "9e9dcf4a-3b83-4e15-a8d0-6f5351cdc13c", "name": "l(r:p1rdt8473lv-p1rlv18169)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "439728c5-fee5-4dfa-9894-261ba6c40e95"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c1eac45-623a-4f0a-874d-a4b56a8e2ea7"}}}], "length": {"value": 0.0202596, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "8285453f-abc7-420b-93ac-60cb9aaef09e", "name": "l(r:p1rdt8473lv-p1rlv18194)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "439728c5-fee5-4dfa-9894-261ba6c40e95"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "949f4cce-f321-4bf0-830b-489edc9964c7"}}}], "length": {"value": 0.0202596, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "d9d639df-5b76-47fe-9b75-d4e7ec515ae1", "name": "l(r:p1rdt6028lv-p1rlv12518)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35f6f747-811d-4fe2-a9c7-991248572c74"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72f659b6-d302-4887-a2f6-1a477ad3324c"}}}], "length": {"value": 0.0196521, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "9475313a-299b-446b-91ed-94cdb2d345d5", "name": "l(r:p1rdt6028lv-p1rlv12528)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35f6f747-811d-4fe2-a9c7-991248572c74"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9660b80-0fce-4be4-b541-743d5811133c"}}}], "length": {"value": 0.0563852, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "ffe84a3b-76b8-4dec-9c29-0084691588fe", "name": "l(r:p1rdt6028lv-p1rlv12534)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35f6f747-811d-4fe2-a9c7-991248572c74"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8796d817-aad6-4d22-b3d4-baf8a686c9df"}}}], "length": {"value": 0.00754144, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "4a309f30-e352-4599-9dee-ffca476a4e9e", "name": "l(r:p1rdt6028lv-p1rlv12536)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35f6f747-811d-4fe2-a9c7-991248572c74"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e89452f3-ce44-46d3-a259-f66044e01c2c"}}}], "length": {"value": 0.0368264, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "7399e1c5-5e83-4fa9-a9b6-9d3a1a693f55", "name": "l(r:p1rdt9478lv-p1rlv20501)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddf38626-1223-429f-a903-98f1c975020b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cebe1b53-cca6-4bd4-a9f0-616ffb9750b3"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "f3e4b646-2702-4787-930b-a42a5c45d53f", "name": "l(r:p1rdt6232lv-p1rlv12985)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e2630e1-a215-4740-9327-fa004e89863d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df3aae83-f4b0-4db2-9301-dff1664ac23e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "8e5baa4c-dd50-4330-b9cb-45f46ac26d1c", "name": "l(r:p1rdt6232-p1rdt9478)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c49b6e87-5834-4e7e-a64c-b4ec0f7d4995"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b59ad93a-cca2-4a77-8515-a645ddd2a320"}}}], "length": {"value": 0.08088850000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d287939e-187e-44ce-adc8-c5deb1efe035", "name": "l(r:p1rdt6028-p1rdt9478)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e39cb1db-d6a6-4b6c-bc73-920e0c34c292"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f77960bf-f017-400c-b505-16e7c2e90fe7"}}}], "length": {"value": 0.29557, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "38175911-904e-413e-b9f3-ba12b0d54714", "name": "l(r:p1rdt6028-p1rdt8473)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3a83211-0829-4e2c-b618-3f1fcaba3e87"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e39cb1db-d6a6-4b6c-bc73-920e0c34c292"}}}], "length": {"value": 0.233087, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "24ba44ff-6a1e-424c-802a-5e685da39576", "name": "l(r:p1rdt7711-p1rdt8473)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2131350-dc34-4d8d-8c9f-c29e25bc654c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3a83211-0829-4e2c-b618-3f1fcaba3e87"}}}], "length": {"value": 0.502313, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "c94a5bb4-b7c5-4f79-9cf8-1375d4c8b6cb", "name": "l(r:p1rdt8493lv-p1rlv18201)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c330731a-fd2c-40c7-8fce-94f7e17cf6d9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ead37cb8-af1e-4a46-9466-6ff298b7f8b7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "248b171b-5e13-4070-b36a-12d088475c3c", "name": "l(r:p1rdt7711-p1rdt8493)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2131350-dc34-4d8d-8c9f-c29e25bc654c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfb41891-7063-44b8-9286-1fe763e49924"}}}], "length": {"value": 0.719466, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "5cd18c4b-7e66-4567-99aa-adbf0e339973", "name": "l(r:p1rdt6028-p1rdt9478)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f77960bf-f017-400c-b505-16e7c2e90fe7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "409a29cf-ddd5-4031-92ca-db6cd2410704"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "937849ae-e1ac-40fe-b786-984a89a281f3", "name": "l(r:p1rdt6028-p1rdt9478)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "409a29cf-ddd5-4031-92ca-db6cd2410704"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c49b6e87-5834-4e7e-a64c-b4ec0f7d4995"}}}], "length": {"value": 2.66913, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "87fc45c2-660b-4f99-b658-eb377ae27502", "name": "l(r:p1rdt93lv-p1rlv183)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0921e58d-1ada-4556-8b01-8f22d3bf4ee2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3df778b4-e60b-4e17-b24b-67742d090f42"}}}], "length": {"value": 0.062918, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0c7ce66f-32b1-4f29-8c1b-ff8cb7cbe189", "name": "l(r:p1rdt93lv-p1rlv204)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0921e58d-1ada-4556-8b01-8f22d3bf4ee2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d663fcdc-6c67-4bc9-99ed-12439f75804f"}}}], "length": {"value": 0.0275441, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c67015ab-e194-4fac-82b0-87878c41d658", "name": "l(r:p1rdm198-p1rlv206)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2be21180-bfa8-4cd1-a3c5-68602896d657"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90aa0d14-285a-4468-bbde-8d76f65b1780"}}}], "length": {"value": 0.047457, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "04bb6407-6835-4d3c-8629-76af3bf1c2ae", "name": "l(r:p1rdm198-p1rdt93lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0921e58d-1ada-4556-8b01-8f22d3bf4ee2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2be21180-bfa8-4cd1-a3c5-68602896d657"}}}], "length": {"value": 0.0116535, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8364cd7f-2820-4bcf-bb37-67dadafb4bb2", "name": "l(r:p1rdm199-p1rlv207)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a70fd02-3816-451f-a509-2ad767068eb4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6627102c-4524-4e69-bb4d-5b93226df412"}}}], "length": {"value": 0.0665106, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a2920457-6a3e-4fb5-95d3-b5dfbe0a7490", "name": "l(r:p1rdm196-p1rlv184)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6065e92f-dd89-4aeb-94af-173d81a49df1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42ca8327-5dcc-415a-820c-ef6ec038b3d8"}}}], "length": {"value": 0.0719696, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "382af86a-c688-4778-b6b8-2005858ec39b", "name": "l(r:p1rdm196-p1rdm199)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a70fd02-3816-451f-a509-2ad767068eb4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6065e92f-dd89-4aeb-94af-173d81a49df1"}}}], "length": {"value": 0.0157359, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "796dcb0c-914a-4476-8a88-6a5c6023faca", "name": "l(r:p1rdm199-p1rdt93lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0921e58d-1ada-4556-8b01-8f22d3bf4ee2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a70fd02-3816-451f-a509-2ad767068eb4"}}}], "length": {"value": 0.00889089, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "2d347746-0969-4a8a-b986-c40ef4f4c015"}}}}, {"uuid": "3a950c68-44a5-458a-ae67-40de974d8047", "name": "l(r:p1rdt99lv-p1rlv190)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef6be92d-5d1b-40e2-a2c2-9d0c1f0bf596"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33b6400e-c84e-43cf-b254-99f946e5a308"}}}], "length": {"value": 0.040055, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4ab7dd7f-8f59-4338-807a-6a59fdb9d2c6", "name": "l(r:p1rdt99lv-p1rlv202)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef6be92d-5d1b-40e2-a2c2-9d0c1f0bf596"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "de2366e4-30da-429a-82b9-c0ef27eeab47"}}}], "length": {"value": 0.040055, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c79aa124-41f0-475e-b27b-c7974a25b335", "name": "l(r:p1rdt101lv-p1rlv193)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1277a701-9fbd-4853-a809-962475e016c4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84223c1b-69e4-4ebc-8274-8706bb412780"}}}], "length": {"value": 0.060663, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "5ef15021-e9f7-4934-ad47-fa982ef83d7f", "name": "l(r:p1rdt108lv-p1rlv212)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3aa8d6f2-8d84-42d6-8e7b-89e3b1efa03c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a982feac-5730-4fe0-a1b8-25c06b36e3b0"}}}], "length": {"value": 0.0158014, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9ba90c4e-cda5-4a96-8214-9766f675c80a", "name": "l(r:p1rdt6121lv-p1rlv12687)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "448cc5e0-391f-4a6b-8199-25cef4593edf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "163c3824-6847-4b94-9e81-08f15f4667a1"}}}], "length": {"value": 0.0852199, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b466ad0c-36a2-4215-b99e-1e2e9147cca4", "name": "l(r:p1rdt6123lv-p1rlv12713)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e81ba94-5857-42e4-aeee-58542cef0fb6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff16aad0-98c1-4563-a844-e0ce909c1a79"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "6db4a71c-d59e-49fb-b9ee-3aebd949e6ab", "name": "l(r:p1rdt8017lv-p1rlv17006)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8428de0e-4b06-4f19-bffb-5fed32f96f67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b53edd15-5a3e-4b7a-97c4-046582bb4801"}}}], "length": {"value": 0.0396626, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6f7024dc-43c4-4070-b610-d88c786d2e4b", "name": "l(r:p1rdt8043lv-p1rlv17103)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a367e687-b29a-44b4-a943-7b94762e549e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ff9eb4c-2523-48e0-8490-619d26b9cca4"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b797d3a2-ee2f-4f54-b06e-9fa0e6dbb21e", "name": "l(r:p1rdt8065lv-p1rlv17155)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8bb025c5-31eb-4771-b433-e1dcad03b3ed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3c6c52e-cf93-467a-a303-94b96b33a3da"}}}], "length": {"value": 0.00641649, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6f467e58-32b6-4e07-9a32-2fcae57445d9", "name": "l(r:p1rdm17752-p1rlv17164)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62e77e46-bf33-474f-907b-81d36aae8975"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "041caa30-2985-44ca-8013-e11a9bda7dff"}}}], "length": {"value": 0.0585553, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "aa9f431f-8d45-4d2f-b3ef-6ed973e7fdfe", "name": "l(r:p1rdm17752-p1rdt8068lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd01eed6-0e70-42e7-ac29-4bfd2f70366a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62e77e46-bf33-474f-907b-81d36aae8975"}}}], "length": {"value": 0.00975828, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "46cadd28-41d2-4b33-b229-53938b6526d2", "name": "l(r:p1rdm17753-p1rlv17199)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "46b5c5bc-6738-4520-b98c-32bd43f4c91c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5768eaca-abe3-4347-af78-02b50ec6f2a9"}}}], "length": {"value": 0.07246250000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "815be72a-4590-47bf-b23a-93bee76e3ffc", "name": "l(r:p1rdm17753-p1rdt8068lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd01eed6-0e70-42e7-ac29-4bfd2f70366a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "46b5c5bc-6738-4520-b98c-32bd43f4c91c"}}}], "length": {"value": 0.00869985, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "07d3ecbb-c8d8-4498-b7de-9dede233fa9a", "name": "l(r:p1rdt8070lv-p1rlv17167)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0bcd460-ccf2-42ee-83c6-bada397ab4d6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b4e44ab-e644-4e48-b1b2-82dc15d38d17"}}}], "length": {"value": 0.0455049, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e1c383ad-81e0-4ef4-8d77-433f8c2369fc", "name": "l(r:p1rdt8190lv-p1rlv17376)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f21f4e99-8877-4bb0-9956-9240bc6db3d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c9970ae-e914-407d-8222-12c08638a854"}}}], "length": {"value": 0.0538062, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "5c4315d9-3bd5-4e8d-8f59-4e452cc39791", "name": "l(r:p1rdt8204lv-p1rlv17402)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d12bf6fb-8dac-4729-bcda-1ee61c63f6e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc7fa312-1baf-4f23-925f-a281071183a6"}}}], "length": {"value": 0.020109400000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "930a8c5d-1c84-449e-aeb0-b249e1fc8fbe", "name": "l(r:p1rdt8208lv-p1rlv17413)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ecf11723-eb6d-423c-ac0c-85fa2d1ba846"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f147f7e5-33e8-430b-9822-715e772debb3"}}}], "length": {"value": 0.058289, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "49a21a95-e38f-4a69-be2a-b889705a3a47", "name": "l(r:p1rdt8578lv-p1rlv18362)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1a593e3-4735-47d2-b893-dd2d07c3c47c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a28b095-45f5-43ec-983b-c1de596d4cb5"}}}], "length": {"value": 0.0205693, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "dc98da20-4587-480f-8cb1-3a411d9e0658", "name": "l(r:p1rdt8578lv-p1rlv18364)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1a593e3-4735-47d2-b893-dd2d07c3c47c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d1c3d0a-9def-4516-8429-386f1d70f506"}}}], "length": {"value": 0.0370574, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f8487d44-54da-4eec-870f-b9de934b0640", "name": "l(r:p1rdt8578lv-p1rlv18367)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1a593e3-4735-47d2-b893-dd2d07c3c47c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "408c825d-17ac-4aea-9fc7-fff420657fc7"}}}], "length": {"value": 0.018828, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cce59d54-5697-4708-a924-410992705356", "name": "l(r:p1rdt8583lv-p1rlv18370)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "134bac3d-5b7e-48d7-950e-01e5b7d43852"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905e171c-13d7-4f8d-b88a-7501b2327d81"}}}], "length": {"value": 0.0934621, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "72285fbb-7891-4916-bd04-d67ce9189e58", "name": "l(r:p1rdt8584lv-p1rlv18371)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8ba1042-fcfd-47a8-aa0f-8b13618d3212"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58792e8c-3ad9-45bb-ac47-01983cca2a2b"}}}], "length": {"value": 0.0568796, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0ed44728-cace-4d39-8182-28659b1113a8", "name": "l(r:p1rdt10491lv-p1rlv22745)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8f14e6e-ee96-4ae9-86ba-4a07cf103b65"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a86348e4-7573-4903-b223-90155579923e"}}}], "length": {"value": 0.00860717, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "69f39247-71ec-4488-a1b5-9cd9caff8cb6", "name": "l(r:p1rdm23269-p1rlv22758)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee8b6bab-9edd-4250-b57b-3a76b432fb54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db05b7f0-d2a8-4876-876e-ef0e9b469580"}}}], "length": {"value": 0.0077383, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "545f2993-60ea-4122-8ac8-124799e17c31", "name": "l(r:p1rdm23269-p1rdt10491lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8f14e6e-ee96-4ae9-86ba-4a07cf103b65"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee8b6bab-9edd-4250-b57b-3a76b432fb54"}}}], "length": {"value": 0.017970700000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a19ed19d-f5f9-42c8-b5d1-520605196747", "name": "l(r:p1rdt8065-p1rdt8070)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473520c7-0098-4bc2-a46f-07efd6c3759c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "862f3566-9443-4b82-8f05-c994581e131a"}}}], "length": {"value": 0.11506000000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f82ea167-4bb5-4acb-8736-ba3098b01929", "name": "l(r:p1rdt8068-p1rdt8070)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473520c7-0098-4bc2-a46f-07efd6c3759c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f5fbb8b-0c32-4aa7-acaf-7ea2b5e56505"}}}], "length": {"value": 0.0454225, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "2cfe2726-ca82-4184-af38-1db485d3622d", "name": "l(r:p1rdt8043-p1rdt8070)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "691c1909-3b71-4e07-abf0-95aaabfa23bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbafbe81-1649-4bae-b9af-c4b1757392f0"}}}], "length": {"value": 1.20903, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c939ca25-23bc-45e6-afb1-34c98b300b8d", "name": "l(r:p1rdt8043-p1rdt8070)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbafbe81-1649-4bae-b9af-c4b1757392f0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473520c7-0098-4bc2-a46f-07efd6c3759c"}}}], "length": {"value": 0.714168, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1a6283f9-eca9-4da3-9aec-868e430d702b", "name": "l(r:p1rdt10491-p1rdt8043)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "691c1909-3b71-4e07-abf0-95aaabfa23bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ca19324f-0855-4633-be68-b16c872e196d"}}}], "length": {"value": 0.143178, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f42fe8fc-80ec-4c50-a106-91fa534f3edc", "name": "l(r:p1rdt10491-p1rdt8043)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ca19324f-0855-4633-be68-b16c872e196d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4737e613-8cf5-45d7-a3f5-71af051ece4c"}}}], "length": {"value": 1.81692, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d5dee6d5-a427-4319-b9b9-44bc16841f5f", "name": "l(r:p1rdt8017-p1rdt8043)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6378abd-969e-4ec8-93eb-2cc39cdb18eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "feda8d99-6fae-4c6e-bf52-f87894687da5"}}}], "length": {"value": 0.18707900000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ccb7a0ac-a308-4217-afd4-043b2b325c6b", "name": "l(r:p1rdt8017-p1rdt8043)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "feda8d99-6fae-4c6e-bf52-f87894687da5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "691c1909-3b71-4e07-abf0-95aaabfa23bb"}}}], "length": {"value": 0.534353, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "db26ea21-d0ad-492d-88d3-62e4b8b52675", "name": "l(r:p1rdt101-p1rdt8017)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a09cdbca-4e7b-4d9a-b479-515074964171"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1aeba4b-536e-4067-a7a5-627470ae0711"}}}], "length": {"value": 0.331129, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b5b98590-9dc7-4cd0-a4d2-066a47550a6e", "name": "l(r:p1rdt101-p1rdt8017)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1aeba4b-536e-4067-a7a5-627470ae0711"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c1a4365-a594-48be-b138-aa6935c34481"}}}], "length": {"value": 2.00417, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e7f6e4db-47b4-40d6-b0c7-8836d796842d", "name": "l(r:p1rdt101-p1rdt8017)_s2", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c1a4365-a594-48be-b138-aa6935c34481"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6378abd-969e-4ec8-93eb-2cc39cdb18eb"}}}], "length": {"value": 0.0990287, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "358ea440-8af5-49f3-a7e5-bf3ece06fe47", "name": "l(r:p1rdt101-p1rdt108)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e61ce952-a643-45aa-a466-8aa15ecceb48"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d8e5d83-cd9c-4527-9eef-6219c98dfe93"}}}], "length": {"value": 0.0862881, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e86bf583-73fe-41bb-bdae-274719a15774", "name": "l(r:p1rdt108-p1rdt93)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4f100ee-0152-4e27-bf0e-2c7dea1537ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e61ce952-a643-45aa-a466-8aa15ecceb48"}}}], "length": {"value": 0.0403624, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "73cf1758-bfb1-404d-80ef-ae8deceb880c", "name": "l(r:p1rdt8204-p1rdt8208)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e2b4d77-2388-4897-86fe-06409fa9d222"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa2342e6-2d40-424a-830c-a84af4632b6e"}}}], "length": {"value": 0.29712, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bc1ca79c-0481-4721-87d4-46e512a8cdcd", "name": "l(r:p1rdt8190-p1rdt8208)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a761aef-a766-40e2-b8d7-e5a918cece18"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e2b4d77-2388-4897-86fe-06409fa9d222"}}}], "length": {"value": 0.056324900000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e3ede097-3f6e-463a-8da9-8632b7c482b3", "name": "l(r:p1rdt8190-p1rdt99)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b860d5c-43e4-429e-b945-378020e3f926"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6be75535-8c32-47ea-bad5-986daaed0921"}}}], "length": {"value": 1.66165, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "700118f2-7a55-4195-9574-c5978603f45e", "name": "l(r:p1rdt8190-p1rdt99)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6be75535-8c32-47ea-bad5-986daaed0921"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a761aef-a766-40e2-b8d7-e5a918cece18"}}}], "length": {"value": 0.18014, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1b462af5-d08e-4ef0-a01e-73536834674c", "name": "l(r:p1rdt6121-p1rdt6123)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddf8f344-dcca-418d-850e-745f18d29660"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17f807ba-6ad6-4fd9-9dd0-2c0bacea5b24"}}}], "length": {"value": 0.192685, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d1b3aa3f-5f80-4d51-a2cd-0171c797aabb", "name": "l(r:p1rdt8583-p1rdt8584)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0747505-3381-4df0-a86e-3859acac8496"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b601580-3091-4d8c-9718-1367c7ed385f"}}}], "length": {"value": 0.11744700000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5a01c8c2-afff-4ba5-957f-a2692170814e", "name": "l(r:p1rdt93-p1rdt99)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "092a9d51-a39c-4c05-905e-93fb1ae96ba2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3d15ce6-878d-4dd5-bb33-5a0f6c11dded"}}}], "length": {"value": 0.141059, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "9a0a937c-8779-4945-b7a2-5c75476497cb", "name": "l(r:p1rdt93-p1rdt99)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3d15ce6-878d-4dd5-bb33-5a0f6c11dded"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "900d49ce-4834-4f99-8d74-a5e9d2f63ea0"}}}], "length": {"value": 0.0271696, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "bcaefac9-1c3b-4558-a4c8-277deff0ddcc", "name": "l(r:p1rdt6121-p1rdt99)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2390c014-d418-4d63-8438-529a036487db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49c9e6df-3490-4df1-88a0-8a83ca6cdd1e"}}}], "length": {"value": 0.978472, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "0aff09d1-b70c-477f-bd3b-0d2d1a8a6a03", "name": "l(r:p1rdt6121-p1rdt99)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49c9e6df-3490-4df1-88a0-8a83ca6cdd1e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "092a9d51-a39c-4c05-905e-93fb1ae96ba2"}}}], "length": {"value": 0.2822120000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "ec452fcc-6021-44bc-9ae1-4cb5035bb351", "name": "l(r:p1rdt6121-p1rdt8578)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb866499-9e9c-4394-bd76-d4320ba4934b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "af229e5c-a70f-4354-bddc-4a2698802741"}}}], "length": {"value": 0.28336300000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "439d6b78-6099-4abb-8944-85f4bdab8a16", "name": "l(r:p1rdt6121-p1rdt8578)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "af229e5c-a70f-4354-bddc-4a2698802741"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2390c014-d418-4d63-8438-529a036487db"}}}], "length": {"value": 3.58548, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "1950c059-99fb-4401-9f5c-76a93b596633", "name": "l(r:p1rdt8578-p1rdt8583)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dbb79e10-21ba-4f04-b8a3-0cf711d26d40"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "975237e9-bd83-4a30-83ab-221eb7f85c65"}}}], "length": {"value": 0.101019, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "562e52da-0402-4236-9daa-19322b4c4c58", "name": "l(r:p1rdt8578-p1rdt8583)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "975237e9-bd83-4a30-83ab-221eb7f85c65"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb866499-9e9c-4394-bd76-d4320ba4934b"}}}], "length": {"value": 0.293916, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "2e7af12b-e8d8-4dd6-b6a9-cd3b777924ce", "name": "l(r:p1rdt8583-p1rhs7_1247)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec7726f8-0afb-4c35-8a1b-0691a8fb400d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dbb79e10-21ba-4f04-b8a3-0cf711d26d40"}}}], "length": {"value": 1.53928, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "7393d5be-c8ab-4241-b345-50487d39c030", "name": "fuse(r:p1rdt108-p1rdt93)p1r_16636", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "900d49ce-4834-4f99-8d74-a5e9d2f63ea0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4f100ee-0152-4e27-bf0e-2c7dea1537ad"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "3b608405-4c97-4531-bc3d-fd9d98d5eef0", "name": "fuse(r:p1rdt8190-p1rdt99)p1r_16637", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "092a9d51-a39c-4c05-905e-93fb1ae96ba2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b860d5c-43e4-429e-b945-378020e3f926"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "872c97b3-853e-44ec-9dc5-76b3b0c97047", "name": "fuse(r:p1rdt6121-p1rdt6123)p1r_17782", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2390c014-d418-4d63-8438-529a036487db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddf8f344-dcca-418d-850e-745f18d29660"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "eebb5679-e562-4c44-912d-f2a3cf81f9a7", "name": "fuse(r:p1rdt8583-p1rdt8584)p1r_18243", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dbb79e10-21ba-4f04-b8a3-0cf711d26d40"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0747505-3381-4df0-a86e-3859acac8496"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "96f5f10a-4b99-43c0-ace7-9392756edbb1", "name": "disswitch(r:p1rdt101-p1rdt8017)p1r_21072", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d8e5d83-cd9c-4527-9eef-6219c98dfe93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a09cdbca-4e7b-4d9a-b479-515074964171"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}], "time_series": {"directory": "p1rhs7_1247_time_series"}} \ No newline at end of file +{"name": null, "description": null, "uuid": "46939f3b-e363-402b-96d5-075fea00bb3c", "data_format_version": "1.4.4", "components": [{"uuid": "b3ec0470-4645-4817-8d9e-36a62dd25e7b", "name": "", "limit_type": "min", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "base"}}, "value": {"value": 37.84531014537997, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}}, {"uuid": "6f2e6cad-94d8-43ba-82be-43800c8ff5c3", "name": "", "limit_type": "max", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "base"}}, "value": {"value": 41.82902700278839, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}}, {"uuid": "198717db-85ba-42fb-bb64-8404694680f4", "name": "", "x": 38.64060097099336, "y": -122.50688851789585, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "574ab810-c1b0-4662-8c4d-f32ab6893a36", "name": "p1rhs7_69", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "b3ec0470-4645-4817-8d9e-36a62dd25e7b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "6f2e6cad-94d8-43ba-82be-43800c8ff5c3"}}}], "nominal_voltage": {"value": 39.83716857408418, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "198717db-85ba-42fb-bb64-8404694680f4"}}}}, {"uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e", "name": "", "limit_type": "min", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "base"}}, "value": {"value": 6.839579963954902, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}}, {"uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4", "name": "", "limit_type": "max", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "base"}}, "value": {"value": 7.559535749634366, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}}, {"uuid": "43cd04c2-460c-452d-86bf-a5589f142291", "name": "", "x": 38.64000605387684, "y": -122.50715315149552, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "30052484-94f2-43a3-abb7-9314d4593c20", "name": "sb10_p1rhs7_1247_bus_10_6", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "43cd04c2-460c-452d-86bf-a5589f142291"}}}}, {"uuid": "03718c17-c4ff-4e1c-8455-8fcf4a4af180", "name": "", "x": 38.63991059999376, "y": -122.50713209215856, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ed5e3889-e8c8-4215-adb8-9880f8937da5", "name": "p1rdt6488-p1rhs7_1247x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "03718c17-c4ff-4e1c-8455-8fcf4a4af180"}}}}, {"uuid": "0488d677-5c3a-4447-9757-a609b80ee957", "name": "", "x": 38.64000458987126, "y": -122.50680575213045, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "23779a0d-9859-4591-b4ce-7ec704401d42", "name": "sb10_p1rhs7_1247_bus_10_7", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0488d677-5c3a-4447-9757-a609b80ee957"}}}}, {"uuid": "55ae0586-0c23-44a5-9795-611001c2b35b", "name": "", "x": 38.63990849507586, "y": -122.50663270624317, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1548dd91-bc3d-4a2c-903f-48e11159c558", "name": "p1rdt7711-p1rhs7_1247x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "55ae0586-0c23-44a5-9795-611001c2b35b"}}}}, {"uuid": "fef667d2-e160-4e42-93ec-3fe9b5fa8815", "name": "", "x": 38.64015019482659, "y": -122.50741272190496, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f4d9a6e8-eb1b-454c-ae94-2eb435218fb9", "name": "sb10_p1rhs7_1247_bus_10_4", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fef667d2-e160-4e42-93ec-3fe9b5fa8815"}}}}, {"uuid": "2b867617-7e8c-4db9-ade6-b774fb29b86d", "name": "", "x": 38.64000705978231, "y": -122.50739198857364, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "14208aa5-3197-4c90-adf9-3067dae9b5f9", "name": "p1rdt5342-p1rhs7_1247x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2b867617-7e8c-4db9-ade6-b774fb29b86d"}}}}, {"uuid": "d32bc420-6934-4d7e-91ab-1e3398b02d2c", "name": "", "x": 38.640146717948795, "y": -122.5065876467693, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2427b8de-af1a-44f8-9774-724e635057fb", "name": "sb10_p1rhs7_1247_bus_10_5", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d32bc420-6934-4d7e-91ab-1e3398b02d2c"}}}}, {"uuid": "e9c98454-f906-4403-becb-00deac9c5c8c", "name": "", "x": 38.64000266679855, "y": -122.50634979050211, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ec7726f8-0afb-4c35-8a1b-0691a8fb400d", "name": "p1rdt8583-p1rhs7_1247x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e9c98454-f906-4403-becb-00deac9c5c8c"}}}}, {"uuid": "08b140ca-c960-474e-ac23-6e6580d6298c", "name": "", "x": 38.640398325892065, "y": -122.5068899064944, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "001adbd4-6616-4dce-83d2-025e896ada51", "name": "sb10_p1rhs7_1247_node_10_7", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "08b140ca-c960-474e-ac23-6e6580d6298c"}}}}, {"uuid": "0783a135-88c7-4b30-86a9-f2f6557c594a", "name": "", "x": 38.64033927342312, "y": -122.50702059026854, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3856ea8d-83da-4d2e-8f66-fae6c69b5db1", "name": "sb10_p1rhs7_1247_bus_10_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0783a135-88c7-4b30-86a9-f2f6557c594a"}}}}, {"uuid": "07d60bfb-ce5e-4d51-9638-eb8860046b02", "name": "", "x": 38.64024290434973, "y": -122.50678240569646, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c975b603-30a6-4ed1-bbae-696d1c5b0a3d", "name": "sb10_p1rhs7_1247_bus_10_3", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "07d60bfb-ce5e-4d51-9638-eb8860046b02"}}}}, {"uuid": "7fd62588-3463-4a61-8c5d-1bb88b8c086a", "name": "", "x": 38.640245008643895, "y": -122.50728179394365, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6263cae0-e97a-4044-a130-e971a626d3c1", "name": "sb10_p1rhs7_1247_bus_10_2", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7fd62588-3463-4a61-8c5d-1bb88b8c086a"}}}}, {"uuid": "09d479e2-73cb-4c6e-9182-419e2c7d9217", "name": "", "x": 38.64044600709302, "y": -122.50688957976658, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16bb904e-b153-4b0a-97f5-53ad7c6606d8", "name": "sb10_p1rhs7_1247_node_10_6", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "b3ec0470-4645-4817-8d9e-36a62dd25e7b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "6f2e6cad-94d8-43ba-82be-43800c8ff5c3"}}}], "nominal_voltage": {"value": 39.83716857408418, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "09d479e2-73cb-4c6e-9182-419e2c7d9217"}}}}, {"uuid": "154210fc-9811-4963-880a-2605cc049534", "name": "", "x": 38.64052944919371, "y": -122.50688900799106, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ca7962b4-686c-4bee-af8d-f1851b835adb", "name": "sb10_p1rhs7_1247_node_10_5", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "b3ec0470-4645-4817-8d9e-36a62dd25e7b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "6f2e6cad-94d8-43ba-82be-43800c8ff5c3"}}}], "nominal_voltage": {"value": 39.83716857408418, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "154210fc-9811-4963-880a-2605cc049534"}}}}, {"uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc", "name": "", "limit_type": "min", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "base"}}, "value": {"value": 0.11408441319187004, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}}, {"uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5", "name": "", "limit_type": "max", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "base"}}, "value": {"value": 0.12609329879101427, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}}, {"uuid": "c9b5dc22-6b6c-4e4f-bb66-434e7a4937bf", "name": "", "x": 38.58930068802498, "y": -122.47407241728135, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3541a1a-9680-4baf-9b87-a1322cb1a16a", "name": "p1rdt4964lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c9b5dc22-6b6c-4e4f-bb66-434e7a4937bf"}}}}, {"uuid": "cececd48-9462-4a04-90f8-afe07e75e821", "name": "", "x": 38.58928688389361, "y": -122.47412342379597, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "02e86824-b793-4080-9401-c6995a365baf", "name": "p1rlv10170", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cececd48-9462-4a04-90f8-afe07e75e821"}}}}, {"uuid": "b99a2ad7-5611-486b-890e-ec585d6cdc15", "name": "", "x": 38.58730261534203, "y": -122.47493972983303, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ab731358-e17f-4c48-b6f8-c7bb4c7701de", "name": "p1rdt4980lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b99a2ad7-5611-486b-890e-ec585d6cdc15"}}}}, {"uuid": "88aed81c-9aee-49c7-b399-6d35c3018dbd", "name": "", "x": 38.586999682758396, "y": -122.47455116112062, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "58f2b2c3-4f6f-4fd2-abb9-42ff665692bd", "name": "p1rlv10189", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "88aed81c-9aee-49c7-b399-6d35c3018dbd"}}}}, {"uuid": "d25f087f-69b4-4209-ac90-8818cc55484e", "name": "", "x": 38.5874921997227, "y": -122.47522897778698, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6b4caeee-6304-4a25-a7d8-44c6014b5e37", "name": "p1rlv10574", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d25f087f-69b4-4209-ac90-8818cc55484e"}}}}, {"uuid": "d4aaf336-5d7e-46b9-9bb6-f7d1ed0c4e09", "name": "", "x": 38.587371992400946, "y": -122.47517995477224, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aad9ea92-9403-4ac0-9aaf-7e845b8c7bb5", "name": "p1rlv10596", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d4aaf336-5d7e-46b9-9bb6-f7d1ed0c4e09"}}}}, {"uuid": "5b862a31-20f0-4f36-926e-88ecbddd6658", "name": "", "x": 38.58881837779083, "y": -122.47343065419352, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0375d197-ccd2-4ed8-9439-857b700cefb8", "name": "p1rdt5017lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5b862a31-20f0-4f36-926e-88ecbddd6658"}}}}, {"uuid": "609e696a-a153-4e81-a0de-294f1949fda2", "name": "", "x": 38.58885966670059, "y": -122.47344264204159, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3317d7c2-2588-426d-91fc-3d765b932da6", "name": "p1rlv10262", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "609e696a-a153-4e81-a0de-294f1949fda2"}}}}, {"uuid": "8925aa98-b97a-4609-928a-4c2fb1511718", "name": "", "x": 38.62911239194669, "y": -122.48794713837246, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7e33e473-8d5b-4704-bdab-56032991f94e", "name": "p1rdt5126lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8925aa98-b97a-4609-928a-4c2fb1511718"}}}}, {"uuid": "83e7ddaa-1339-44f6-924d-5a5f6a3cf8cf", "name": "", "x": 38.6290864193847, "y": -122.48790451626458, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8f7116b9-96c1-42c8-850f-7787f5fd0f96", "name": "p1rlv10491", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "83e7ddaa-1339-44f6-924d-5a5f6a3cf8cf"}}}}, {"uuid": "84da10da-2cca-45f7-9864-c2b1098caa40", "name": "", "x": 38.625434851806375, "y": -122.44516017839125, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dd4b469b-001b-4914-8e51-e98fe3f6babb", "name": "p1rdm10619", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "84da10da-2cca-45f7-9864-c2b1098caa40"}}}}, {"uuid": "791f4ebc-b1a0-4617-b265-6f27b679cd92", "name": "", "x": 38.625158815750815, "y": -122.44586307086524, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "31f26b28-fc9d-4b3d-b204-cf40f3478c44", "name": "p1rlv10521", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "791f4ebc-b1a0-4617-b265-6f27b679cd92"}}}}, {"uuid": "905821af-0745-45f1-9947-ecdae59a1230", "name": "", "x": 38.625299188790116, "y": -122.44505783200565, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e28a5f3a-4447-469a-85dd-e232d8c6d728", "name": "p1rdm10620", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "905821af-0745-45f1-9947-ecdae59a1230"}}}}, {"uuid": "fc3d809d-3c65-4bcc-8227-0daa8d5f70f7", "name": "", "x": 38.62519279357018, "y": -122.44542626681253, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "73ada6ad-ace7-46c1-80f7-2cb33cf4cdb3", "name": "p1rlv10641", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fc3d809d-3c65-4bcc-8227-0daa8d5f70f7"}}}}, {"uuid": "fe8f593f-9830-4c8d-8ac2-c631589cabcb", "name": "", "x": 38.625591389135096, "y": -122.44526633659068, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5f114a56-98d7-4fe8-b0b1-b8c4bc791cf9", "name": "p1rdt5140lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fe8f593f-9830-4c8d-8ac2-c631589cabcb"}}}}, {"uuid": "c0c3cf78-7bf0-4327-987d-79699acfeb78", "name": "", "x": 38.62571524353723, "y": -122.44537629052095, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e09d217e-44a5-4013-8d48-8546d6bb1dc3", "name": "p1rdm10621", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c0c3cf78-7bf0-4327-987d-79699acfeb78"}}}}, {"uuid": "b087818c-f0c4-44e8-86b3-a358f5f73403", "name": "", "x": 38.62565276187416, "y": -122.44550314021144, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "07f95ba5-92dd-465f-a38d-8e878243262b", "name": "p1rlv20071", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b087818c-f0c4-44e8-86b3-a358f5f73403"}}}}, {"uuid": "8efabcfe-13b9-41a1-adeb-db0ab55a0905", "name": "", "x": 38.622332296573816, "y": -122.44976008456518, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e071635-4071-470d-be09-4484cb90441a", "name": "p1rdt5142lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8efabcfe-13b9-41a1-adeb-db0ab55a0905"}}}}, {"uuid": "fe5c7977-cf01-48d0-8145-1e49d6d26df0", "name": "", "x": 38.62217684357621, "y": -122.44988366265912, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35d47036-a044-4c67-b5b5-0006e2a3b68e", "name": "p1rlv10523", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fe5c7977-cf01-48d0-8145-1e49d6d26df0"}}}}, {"uuid": "919ab874-ec10-4b43-841d-de5560c6f8ce", "name": "", "x": 38.62245506643117, "y": -122.44964029908394, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a5717e0-080e-46ae-918a-64fe4fcba5d7", "name": "p1rlv10616", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "919ab874-ec10-4b43-841d-de5560c6f8ce"}}}}, {"uuid": "2108dc95-1071-454c-a014-d592b62560ac", "name": "", "x": 38.58825755415666, "y": -122.46710557327793, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ec20ad2-b04f-43fc-ad8d-d41746549a57", "name": "p1rdt5153lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2108dc95-1071-454c-a014-d592b62560ac"}}}}, {"uuid": "8ae7ce00-9a27-47f2-9b8b-068f0cd24e76", "name": "", "x": 38.58776776322457, "y": -122.46703633124763, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a302271d-4cf3-45ff-9308-b9cf31fbefa3", "name": "p1rlv10538", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8ae7ce00-9a27-47f2-9b8b-068f0cd24e76"}}}}, {"uuid": "cae2d3e5-816f-4b6b-958a-6c6d061dfe81", "name": "", "x": 38.58793840849323, "y": -122.4669087674479, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cfbe5665-c020-455a-addc-d3f9514735ed", "name": "p1rlv10586", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cae2d3e5-816f-4b6b-958a-6c6d061dfe81"}}}}, {"uuid": "b2f0ad91-48b4-488d-b58e-a9a570478b91", "name": "", "x": 38.58801998355576, "y": -122.46701150268488, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b91354e-ce50-44d0-a959-fa451bb9cf20", "name": "p1rlv10610", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b2f0ad91-48b4-488d-b58e-a9a570478b91"}}}}, {"uuid": "daf9b693-80a3-42ee-8706-c161353b3bee", "name": "", "x": 38.62299459252021, "y": -122.44285578875113, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "85351f49-cb19-4f71-a6ae-a21f5a48af6f", "name": "p1rdt5155lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "daf9b693-80a3-42ee-8706-c161353b3bee"}}}}, {"uuid": "7717760f-23fb-40cd-a9b0-f0188f35b9f2", "name": "", "x": 38.62296860365152, "y": -122.44281318670158, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4829cd2f-7e61-4386-89ce-89d77d5ef5cf", "name": "p1rlv10540", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7717760f-23fb-40cd-a9b0-f0188f35b9f2"}}}}, {"uuid": "9413b231-e7d1-4a46-adac-dcb6f32db7d4", "name": "", "x": 38.623416278049106, "y": -122.44435741173649, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ba7e3a6b-f62f-432f-afe7-2ebbfc9abd59", "name": "p1rdt5159lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9413b231-e7d1-4a46-adac-dcb6f32db7d4"}}}}, {"uuid": "1c49be6d-fc4c-418f-9b44-644a6e2a42e2", "name": "", "x": 38.62339028972311, "y": -122.44431480889065, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6c722b89-fdaf-416f-863e-02b443375ba1", "name": "p1rlv10544", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1c49be6d-fc4c-418f-9b44-644a6e2a42e2"}}}}, {"uuid": "57af24fc-2f2e-4145-b371-ee77999bac6c", "name": "", "x": 38.62398776024399, "y": -122.44276641347568, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48efdcb9-083c-4e17-a1d2-acb1388f085e", "name": "p1rdt5172lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "57af24fc-2f2e-4145-b371-ee77999bac6c"}}}}, {"uuid": "1d70710d-9a07-4242-a38f-5d47bc190b51", "name": "", "x": 38.62338766087452, "y": -122.44294734474045, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c8a10822-398f-441e-a5ca-73303d832183", "name": "p1rlv10563", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d70710d-9a07-4242-a38f-5d47bc190b51"}}}}, {"uuid": "eb9ecf04-f209-4a45-9ca6-f9115d073e72", "name": "", "x": 38.618803618131444, "y": -122.45181229136102, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dd4155b2-ca55-41d7-bd35-98a5eec8c39a", "name": "p1rdt5179lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eb9ecf04-f209-4a45-9ca6-f9115d073e72"}}}}, {"uuid": "ef045117-9d8f-4b4a-a616-40bcd5391aa5", "name": "", "x": 38.61925559252727, "y": -122.4515026734116, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "94677ede-fd5c-4fbb-bfcd-98cf67b56913", "name": "p1rlv10573", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef045117-9d8f-4b4a-a616-40bcd5391aa5"}}}}, {"uuid": "fd077f51-6fff-413f-bf0e-4488154496fc", "name": "", "x": 38.61839344506758, "y": -122.45214101800151, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a0431d17-75da-48c1-965c-875f61b0e9bf", "name": "p1rlv10583", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fd077f51-6fff-413f-bf0e-4488154496fc"}}}}, {"uuid": "be95eaa2-f600-4067-97f2-e6070d375414", "name": "", "x": 38.62221649276758, "y": -122.44627684656544, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ae26acb3-c2c9-479c-9d19-c30bf00aa8c5", "name": "p1rdt5180lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be95eaa2-f600-4067-97f2-e6070d375414"}}}}, {"uuid": "be1285dd-72ff-4444-817f-574f0346a2c9", "name": "", "x": 38.622228136819786, "y": -122.44632961498499, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25141e20-0a65-4905-b37f-954ed1a8751c", "name": "p1rlv10576", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be1285dd-72ff-4444-817f-574f0346a2c9"}}}}, {"uuid": "10c2c882-6746-444f-b809-677b728156cf", "name": "", "x": 38.58486127149263, "y": -122.47507613100927, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3bbde2e8-42c0-486b-9759-78898d177f93", "name": "p1rdt5183lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10c2c882-6746-444f-b809-677b728156cf"}}}}, {"uuid": "560205af-2471-40f9-8e3e-65f51ade10de", "name": "", "x": 38.584860090382186, "y": -122.47502224179047, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cdfa726f-5606-4ae2-b358-ad664dd7b0e3", "name": "p1rlv10582", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "560205af-2471-40f9-8e3e-65f51ade10de"}}}}, {"uuid": "3337f64c-470e-47ce-a97e-4d4570af0515", "name": "", "x": 38.6246895952918, "y": -122.44633371298471, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1656cc28-8a5b-40da-887f-25605dd336aa", "name": "p1rdt5184lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3337f64c-470e-47ce-a97e-4d4570af0515"}}}}, {"uuid": "6bd43a1d-48a8-4497-b3e4-8d0ec3aab2bc", "name": "", "x": 38.624682565233414, "y": -122.4461539331612, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "53019a8a-b453-4add-9d2d-e4ab380fce67", "name": "p1rlv10589", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6bd43a1d-48a8-4497-b3e4-8d0ec3aab2bc"}}}}, {"uuid": "ddc1bf24-6112-491d-b9b2-c3ffeaac64de", "name": "", "x": 38.624602168391775, "y": -122.44630389385829, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "feb19590-c5f4-4982-9e99-20599f08cfe7", "name": "p1rlv10600", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ddc1bf24-6112-491d-b9b2-c3ffeaac64de"}}}}, {"uuid": "41225cc6-cdcb-463a-a44f-1fbec5c8f0f3", "name": "", "x": 38.62484662068028, "y": -122.44654326007226, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "374d5417-b2c4-4d16-9b91-d2f519921fd8", "name": "p1rlv10621", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "41225cc6-cdcb-463a-a44f-1fbec5c8f0f3"}}}}, {"uuid": "463f4f85-69a4-45bc-87ec-d0f8a40b0c82", "name": "", "x": 38.649308955445846, "y": -122.40285111885804, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf05c1bb-39cc-48b3-a576-18913e0cff13", "name": "p1rdt5195lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "463f4f85-69a4-45bc-87ec-d0f8a40b0c82"}}}}, {"uuid": "4935e47a-85c4-40c5-83a4-8c706d58814d", "name": "", "x": 38.649342089627496, "y": -122.40283537845332, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1b175fcb-d1ee-44eb-8f89-826e40c5db1d", "name": "p1rlv10615", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4935e47a-85c4-40c5-83a4-8c706d58814d"}}}}, {"uuid": "4d8947e5-f3a0-43f2-bb3c-c156b337ea40", "name": "", "x": 38.64914651543566, "y": -122.40280650016945, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3184f056-3b5f-403d-86a0-f9b28d6bb3e3", "name": "p1rlv10634", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d8947e5-f3a0-43f2-bb3c-c156b337ea40"}}}}, {"uuid": "26aa33e2-1edf-424f-b548-410cbaee9b20", "name": "", "x": 38.58803256102546, "y": -122.4709126113251, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "03e7bfdb-ff8b-4142-95ef-8d848ff5d2db", "name": "p1rdt5200lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "26aa33e2-1edf-424f-b548-410cbaee9b20"}}}}, {"uuid": "eedd822e-ac93-4283-b769-4a115d88068e", "name": "", "x": 38.58800658229211, "y": -122.47087001955629, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32406d7d-51f9-4c16-900b-526985e5f62b", "name": "p1rlv10627", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eedd822e-ac93-4283-b769-4a115d88068e"}}}}, {"uuid": "5e69e0e7-a169-409b-aa08-29275566fae9", "name": "", "x": 38.62310262007371, "y": -122.44472743619623, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b8162a8c-5339-4f42-bd7a-b6dbc5ff463b", "name": "p1rdt5201lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5e69e0e7-a169-409b-aa08-29275566fae9"}}}}, {"uuid": "8a684d6a-e879-403d-b98a-145e2c82abb8", "name": "", "x": 38.623076631881446, "y": -122.44468483339944, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e183b3e8-d995-4f1e-baee-8d9d4add157e", "name": "p1rlv10629", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8a684d6a-e879-403d-b98a-145e2c82abb8"}}}}, {"uuid": "009b7291-1ad4-4e31-812f-20a22582b7f8", "name": "", "x": 38.647579222155, "y": -122.40883933742933, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "39eaedd7-75b6-449f-8ff6-6e31f6e74504", "name": "p1rdt5202lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "009b7291-1ad4-4e31-812f-20a22582b7f8"}}}}, {"uuid": "737a5433-f6cd-4820-bed5-b01766e07a38", "name": "", "x": 38.64738178775039, "y": -122.40899959560872, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8d60a935-dc9b-48ea-8ee7-9b682452035e", "name": "p1rlv10630", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "737a5433-f6cd-4820-bed5-b01766e07a38"}}}}, {"uuid": "a1331dcf-bb83-4354-a0d1-9adaf14bd4a2", "name": "", "x": 38.645656291690415, "y": -122.4075034535507, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "599a2995-33d5-4bcc-8cd3-585ea37577cd", "name": "p1rdt5206lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a1331dcf-bb83-4354-a0d1-9adaf14bd4a2"}}}}, {"uuid": "76105b9d-ef6e-4669-aa1a-d7354b4c1846", "name": "", "x": 38.64561400003638, "y": -122.40750498256921, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e9510bd0-2bba-4522-bfbe-20b94ea400b6", "name": "p1rlv10637", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "76105b9d-ef6e-4669-aa1a-d7354b4c1846"}}}}, {"uuid": "3b3ae9e8-ee45-4b39-a9d2-b653896ffc6e", "name": "", "x": 38.65641154150713, "y": -122.39587823120766, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c650eda9-132b-4419-a055-ad68037c7772", "name": "p1rdt5218lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3b3ae9e8-ee45-4b39-a9d2-b653896ffc6e"}}}}, {"uuid": "f8592191-94d2-423d-a9cc-66bf4448c219", "name": "", "x": 38.656425923289945, "y": -122.39592902455765, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8198c1c5-67e0-49b9-b11a-1f266f7f4bcb", "name": "p1rlv10663", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f8592191-94d2-423d-a9cc-66bf4448c219"}}}}, {"uuid": "cc50144a-f184-4913-a41b-8e0739907a56", "name": "", "x": 38.641472751242716, "y": -122.48093037801921, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5f252d81-66ee-40a6-bce7-2891e06b39e4", "name": "p1rdt5236lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc50144a-f184-4913-a41b-8e0739907a56"}}}}, {"uuid": "6a6587af-c013-4f7f-a20c-cca2a39b8c90", "name": "", "x": 38.64148709617754, "y": -122.48098117829157, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d3d48c0e-704d-4205-94a2-ee74be7ae350", "name": "p1rlv10720", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a6587af-c013-4f7f-a20c-cca2a39b8c90"}}}}, {"uuid": "69d6c981-12fa-4fb6-b646-c5cc5e4d9eaf", "name": "", "x": 38.641937121819915, "y": -122.50369495559332, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e01069aa-388b-4362-9d02-a164f173dc20", "name": "p1rdt5342lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "69d6c981-12fa-4fb6-b646-c5cc5e4d9eaf"}}}}, {"uuid": "dc80310e-0c48-4dc4-ba11-988bd5a787f0", "name": "", "x": 38.64182806242219, "y": -122.50347514079304, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75dbf8f0-4cb6-49b7-a2a5-f98e9ff4b8df", "name": "p1rlv10955", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dc80310e-0c48-4dc4-ba11-988bd5a787f0"}}}}, {"uuid": "f9149994-925b-428c-8a33-66b8460df8e8", "name": "", "x": 38.642018719214704, "y": -122.50380705470455, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0a8fc823-6fe8-4a3b-9437-68aa751f5e3b", "name": "p1rlv11048", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f9149994-925b-428c-8a33-66b8460df8e8"}}}}, {"uuid": "86ec09c9-13eb-44cd-a1b1-3711d57cfccb", "name": "", "x": 38.642205431006985, "y": -122.4576909223735, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "34a1276e-c702-4c69-b7b1-566d400da2de", "name": "p1rdt5472lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "86ec09c9-13eb-44cd-a1b1-3711d57cfccb"}}}}, {"uuid": "c8226150-c622-4980-9f33-95cb9cf66220", "name": "", "x": 38.64217944750302, "y": -122.4576483036143, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f949a06a-817e-4666-95bb-9536ce06a694", "name": "p1rlv11380", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c8226150-c622-4980-9f33-95cb9cf66220"}}}}, {"uuid": "d51b82c8-7885-4679-b8ed-12a631d090e7", "name": "", "x": 38.63960343978653, "y": -122.45649923239668, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5d181674-9355-488b-8a3f-5b7c844c35a5", "name": "p1rdt5475lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d51b82c8-7885-4679-b8ed-12a631d090e7"}}}}, {"uuid": "c119fba5-939c-479d-8bec-f034962dca28", "name": "", "x": 38.63981590397471, "y": -122.45628682931535, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e0c23aea-471f-4d10-9500-1bc14a67d7e7", "name": "p1rlv11384", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c119fba5-939c-479d-8bec-f034962dca28"}}}}, {"uuid": "f9b337b1-5557-4cd2-90b5-fe2127096eaf", "name": "", "x": 38.63963394395313, "y": -122.45652552675769, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7f512d86-c9d9-4f58-9d5a-418d0732dc94", "name": "p1rlv11386", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f9b337b1-5557-4cd2-90b5-fe2127096eaf"}}}}, {"uuid": "ee00163c-6526-4f99-80db-96be6a310440", "name": "", "x": 38.63927702838603, "y": -122.4566815679821, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9fd316b0-fd98-4193-9c1b-aaa7d92a4284", "name": "p1rlv11397", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ee00163c-6526-4f99-80db-96be6a310440"}}}}, {"uuid": "68f4463f-0f9f-4317-a2f9-fbe04b0afa9d", "name": "", "x": 38.639428183564455, "y": -122.46174457730311, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0888f4c5-e037-4891-99fb-fd43934ffae0", "name": "p1rdt5476lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "68f4463f-0f9f-4317-a2f9-fbe04b0afa9d"}}}}, {"uuid": "49097a9b-5c02-4d19-9fce-192f24b100ec", "name": "", "x": 38.639434265073014, "y": -122.46179953026234, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2115e8bb-fe49-49ad-8687-68feca212557", "name": "p1rlv11385", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "49097a9b-5c02-4d19-9fce-192f24b100ec"}}}}, {"uuid": "9f133821-96eb-4579-aee6-925be1a09527", "name": "", "x": 38.642101120835456, "y": -122.45608173877747, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fafd64c3-efe5-4684-b06f-44e4c8555aa4", "name": "p1rdt5477lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9f133821-96eb-4579-aee6-925be1a09527"}}}}, {"uuid": "1cf42564-0cee-4e41-85fc-b6e4694082f9", "name": "", "x": 38.64166518451146, "y": -122.45668651807028, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cbca8c57-0da4-4368-9821-7a9ca4282173", "name": "p1rlv11387", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1cf42564-0cee-4e41-85fc-b6e4694082f9"}}}}, {"uuid": "c753ea66-6b44-4f63-9692-64bd0a9737e0", "name": "", "x": 38.63719096576592, "y": -122.45830192704182, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5107bc9c-f463-49f6-a92f-23c5730475e2", "name": "p1rdt5478lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c753ea66-6b44-4f63-9692-64bd0a9737e0"}}}}, {"uuid": "6e9acac3-2384-45c3-b797-5bcce4603394", "name": "", "x": 38.63771659092773, "y": -122.4583249236366, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "12377bf0-f258-4c29-ab26-e938c95ee25c", "name": "p1rlv11388", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6e9acac3-2384-45c3-b797-5bcce4603394"}}}}, {"uuid": "38e78d90-477b-4736-9dde-04ab72558727", "name": "", "x": 38.63670708849592, "y": -122.4582865622578, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "97aa01fe-2e60-4617-8c89-d36f425087fe", "name": "p1rlv11398", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "38e78d90-477b-4736-9dde-04ab72558727"}}}}, {"uuid": "4f990b5f-70ec-4d45-b79a-ee56910b1e0d", "name": "", "x": 38.64171847326658, "y": -122.45537480795159, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "004f56b2-ec94-4189-91b8-46b4af22faa6", "name": "p1rdm11569", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4f990b5f-70ec-4d45-b79a-ee56910b1e0d"}}}}, {"uuid": "b46ddb8c-258a-46e0-9cc5-ce3594b0f2a0", "name": "", "x": 38.64245774536079, "y": -122.45464667599991, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9b6420b1-3456-42fc-9266-c2b84e063cec", "name": "p1rlv11390", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b46ddb8c-258a-46e0-9cc5-ce3594b0f2a0"}}}}, {"uuid": "94a3ded1-2e9b-42c2-9115-27ab1198f1ad", "name": "", "x": 38.641798080115834, "y": -122.45558638857214, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "44ac9e38-8ae3-4102-822b-1c638a6c878a", "name": "p1rdt5480lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "94a3ded1-2e9b-42c2-9115-27ab1198f1ad"}}}}, {"uuid": "9c167415-a423-4f44-bf0d-2c02116b5458", "name": "", "x": 38.64189515756268, "y": -122.45575404043835, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8be902f6-4cca-4ce5-9f73-a1f96c65d8ef", "name": "p1rdm11570", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9c167415-a423-4f44-bf0d-2c02116b5458"}}}}, {"uuid": "b944b2db-b9e5-412c-9cf9-8b7a3f920690", "name": "", "x": 38.64223524158617, "y": -122.45524587802178, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a215d7dd-8081-4355-9c38-4fd3d2c859c7", "name": "p1rlv11401", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b944b2db-b9e5-412c-9cf9-8b7a3f920690"}}}}, {"uuid": "1b663de6-20e1-48d3-b3c9-6f141c4a5ca7", "name": "", "x": 38.64020129527885, "y": -122.45644080950349, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f213ee9e-6ae7-4e82-9f25-6fc456f45576", "name": "p1rdt5481lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1b663de6-20e1-48d3-b3c9-6f141c4a5ca7"}}}}, {"uuid": "eab215e8-2ae0-46fd-a218-fd08beaa74e3", "name": "", "x": 38.64014090557112, "y": -122.45641076765583, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e740a352-ac8f-4ae2-ace3-254fccd7f96f", "name": "p1rlv11392", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eab215e8-2ae0-46fd-a218-fd08beaa74e3"}}}}, {"uuid": "22a6c911-8788-4f98-b55b-a8a2368bf128", "name": "", "x": 38.640303433007105, "y": -122.45647848222762, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "996d3e44-142c-42fa-bf4f-2bd1777122dd", "name": "p1rlv11394", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "22a6c911-8788-4f98-b55b-a8a2368bf128"}}}}, {"uuid": "7db0ae48-3ebd-433d-9568-05f0c398309d", "name": "", "x": 38.64168447824798, "y": -122.45542011758508, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8a73d544-9f33-49d9-b648-c806addf3c06", "name": "p1rdt5483lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7db0ae48-3ebd-433d-9568-05f0c398309d"}}}}, {"uuid": "81ff1e3e-2885-4592-9965-5945d231f979", "name": "", "x": 38.64195529639681, "y": -122.45512160027936, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "29922f55-f36a-4b9e-8836-5f9dadd641b7", "name": "p1rlv11395", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "81ff1e3e-2885-4592-9965-5945d231f979"}}}}, {"uuid": "288eb15e-e98b-4fdb-824b-6b63988c8235", "name": "", "x": 38.6393583769313, "y": -122.45589692178642, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "40eaefce-482f-4a89-bec1-2c11bac2bfb7", "name": "p1rdt5485lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "288eb15e-e98b-4fdb-824b-6b63988c8235"}}}}, {"uuid": "9a233f64-0a3f-4005-ac29-8df3dc67c147", "name": "", "x": 38.63937273269481, "y": -122.45594771545282, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "68a9eead-8197-4e82-a444-2a4544ec9ddb", "name": "p1rlv11399", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9a233f64-0a3f-4005-ac29-8df3dc67c147"}}}}, {"uuid": "67bfd210-882e-4eb2-b12d-7335778f6e07", "name": "", "x": 38.57143813832739, "y": -122.49015904841082, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "28a6e44b-c6c7-4556-b4d8-d55359391c66", "name": "p1rdt5650lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "67bfd210-882e-4eb2-b12d-7335778f6e07"}}}}, {"uuid": "e6ad383e-e706-44b6-8583-c21c9e8f308d", "name": "", "x": 38.57142432703484, "y": -122.49021003925405, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "834a5733-5264-4adf-861a-25e494df3e37", "name": "p1rlv11671", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e6ad383e-e706-44b6-8583-c21c9e8f308d"}}}}, {"uuid": "3aaeb5f6-c3be-4c8d-ac2c-284fc845d759", "name": "", "x": 38.65464557723489, "y": -122.39724791960451, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "38d1de19-1f51-4875-acc2-a75e3d1a290e", "name": "p1rdt5653lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3aaeb5f6-c3be-4c8d-ac2c-284fc845d759"}}}}, {"uuid": "196dcfb1-cbe1-481a-b575-c37dc4ed0da8", "name": "", "x": 38.65508992916787, "y": -122.39723667691878, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "45f2a901-e4f7-4055-a3e2-b60c61d5033e", "name": "p1rlv11674", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "196dcfb1-cbe1-481a-b575-c37dc4ed0da8"}}}}, {"uuid": "63fded38-9e61-45e7-8ae6-58ed56c3a1c9", "name": "", "x": 38.57263362388283, "y": -122.495683769354, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "87e8c57e-67ff-439c-b28b-0fbdbfd62ea6", "name": "p1rdt5656lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "63fded38-9e61-45e7-8ae6-58ed56c3a1c9"}}}}, {"uuid": "59d4774b-339b-4dc2-9d3d-807731c082ae", "name": "", "x": 38.5726198101849, "y": -122.49573476001369, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8b2f121a-2202-43c0-8684-81913a5d6ea9", "name": "p1rlv11677", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59d4774b-339b-4dc2-9d3d-807731c082ae"}}}}, {"uuid": "c8f6dffd-c572-4d99-b2a4-19421d74334c", "name": "", "x": 38.57280585377797, "y": -122.4929323788313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ea73a91a-b052-486e-810b-1a5ad281e07b", "name": "p1rdt5662lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c8f6dffd-c572-4d99-b2a4-19421d74334c"}}}}, {"uuid": "d4bd3e1e-9577-4201-9f8e-450e5cb4257e", "name": "", "x": 38.57242796617633, "y": -122.49307054728973, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "02aef971-5f4a-4ca8-aa33-cce34517bd44", "name": "p1rlv11684", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d4bd3e1e-9577-4201-9f8e-450e5cb4257e"}}}}, {"uuid": "1c8ccecf-94f0-4086-9894-43ca68c27898", "name": "", "x": 38.56680617078412, "y": -122.49719640898832, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16a67a88-5d11-4eca-85fe-38c948ad362c", "name": "p1rdt5663lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1c8ccecf-94f0-4086-9894-43ca68c27898"}}}}, {"uuid": "da50b7f4-c1bf-47df-ab82-73a5722737b9", "name": "", "x": 38.5668199513191, "y": -122.49730717896358, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cda8e361-98b6-49bd-a3ff-30a036a3dc6f", "name": "p1rlv11686", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "da50b7f4-c1bf-47df-ab82-73a5722737b9"}}}}, {"uuid": "b4ec8b1c-107b-490d-9bb4-eb8aa4f0a2a2", "name": "", "x": 38.56665994983674, "y": -122.49716304017915, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e5b71ca5-a7ab-42f7-824a-bc43fc1708cc", "name": "p1rdm11909", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b4ec8b1c-107b-490d-9bb4-eb8aa4f0a2a2"}}}}, {"uuid": "23b77dd8-f10c-4624-953a-3e440aa570f4", "name": "", "x": 38.566580963860986, "y": -122.49765717235252, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "449098c3-4f65-4350-863f-4b7bc1f14493", "name": "p1rlv15645", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "23b77dd8-f10c-4624-953a-3e440aa570f4"}}}}, {"uuid": "1ba63c10-373f-4350-b961-c90fd652abb4", "name": "", "x": 38.5707010215685, "y": -122.51444963387745, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6d456893-4d89-455a-b1a5-4863aad6293a", "name": "p1rdt5728lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1ba63c10-373f-4350-b961-c90fd652abb4"}}}}, {"uuid": "1f21215a-9d08-4812-8efd-536b0eded845", "name": "", "x": 38.57009391258443, "y": -122.51433495859402, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f0ba1408-17da-4678-8b04-90c616c3fb48", "name": "p1rlv11779", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1f21215a-9d08-4812-8efd-536b0eded845"}}}}, {"uuid": "d07cefa0-6a4a-4ea1-833c-1f8c7239b2ec", "name": "", "x": 38.57127534957151, "y": -122.51454511366566, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3890375-c01d-44d2-93f9-8d9d60da8852", "name": "p1rlv11783", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d07cefa0-6a4a-4ea1-833c-1f8c7239b2ec"}}}}, {"uuid": "65b9e11a-d035-49fe-9c2f-a18adc520bfa", "name": "", "x": 38.56955818331602, "y": -122.51459989092113, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "95f81d7a-a6af-4843-bfa1-002abc7ff870", "name": "p1rdt5729lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65b9e11a-d035-49fe-9c2f-a18adc520bfa"}}}}, {"uuid": "03cf9cc3-74d3-41be-ac9e-4c958be1448f", "name": "", "x": 38.56953222036641, "y": -122.51455729408103, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6e9a574d-9537-417a-a811-e22d84b8ea53", "name": "p1rlv11780", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "03cf9cc3-74d3-41be-ac9e-4c958be1448f"}}}}, {"uuid": "0a193e3d-f76a-4d4c-a33b-8d6eb8250e44", "name": "", "x": 38.57213402094206, "y": -122.51802514483155, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2dd206bc-965d-46c9-8fdb-8c158c7bba05", "name": "p1rdt5730lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a193e3d-f76a-4d4c-a33b-8d6eb8250e44"}}}}, {"uuid": "0198df5e-1335-4d36-b7fa-ea83c51eda03", "name": "", "x": 38.57199490295793, "y": -122.51856958078595, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b66df0bc-6159-42fa-bf49-b8ad17d0e6aa", "name": "p1rlv11784", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0198df5e-1335-4d36-b7fa-ea83c51eda03"}}}}, {"uuid": "1dd4f217-6d64-4bf3-be52-b765773001a9", "name": "", "x": 38.572056756934636, "y": -122.51827070037027, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b15fc66-89d9-483b-9c9f-9b0f39a63b29", "name": "p1rlv11786", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1dd4f217-6d64-4bf3-be52-b765773001a9"}}}}, {"uuid": "3142c953-b8bb-4934-aa7e-9394d697aafe", "name": "", "x": 38.572019292356316, "y": -122.51792656501027, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "64ee7f4c-b91a-4a25-b85d-a91b83777c1f", "name": "p1rdm12071", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3142c953-b8bb-4934-aa7e-9394d697aafe"}}}}, {"uuid": "ea02cc30-f701-4e2e-af04-30113338ce57", "name": "", "x": 38.571920919935685, "y": -122.51811089442202, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "28fd9f7c-0195-4529-a972-aa60eced47d2", "name": "p1rlv11781", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea02cc30-f701-4e2e-af04-30113338ce57"}}}}, {"uuid": "bb99e5fd-69c7-462b-8027-3c89a73aaa07", "name": "", "x": 38.56688129837257, "y": -122.51477378591451, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6e414162-eda7-4cf2-9116-fc24af9461bf", "name": "p1rdt5731lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bb99e5fd-69c7-462b-8027-3c89a73aaa07"}}}}, {"uuid": "a7bd841c-64ad-46a9-9b40-c7c407b24606", "name": "", "x": 38.5669221751359, "y": -122.51444813822336, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "496fc854-bbf8-463b-b16c-12dd1b444cc6", "name": "p1rlv11782", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a7bd841c-64ad-46a9-9b40-c7c407b24606"}}}}, {"uuid": "9b3e1b1d-5f5a-4ed6-bba2-f666acf4a2f6", "name": "", "x": 38.56702296960097, "y": -122.51484921518147, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7103c2f0-8160-434f-b4b3-edfbd7e97464", "name": "p1rdm12075", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9b3e1b1d-5f5a-4ed6-bba2-f666acf4a2f6"}}}}, {"uuid": "72915b72-842d-4d23-8777-a66df68ae209", "name": "", "x": 38.5670581599183, "y": -122.51464236147093, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ed0eb774-fcc3-417f-a8a4-fbdb825cc106", "name": "p1rlv11785", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "72915b72-842d-4d23-8777-a66df68ae209"}}}}, {"uuid": "ac2ebf07-87cc-46ac-affc-3aad7a0927ef", "name": "", "x": 38.57345429314894, "y": -122.51994138004522, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9974869d-7d87-4a27-9606-076cd7799953", "name": "p1rdt5840lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ac2ebf07-87cc-46ac-affc-3aad7a0927ef"}}}}, {"uuid": "dc36d120-77b5-4b62-95f8-a90964499200", "name": "", "x": 38.57328942198139, "y": -122.51998442674298, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1dfd848-b639-41b5-ad95-2c03a51bd36b", "name": "p1rlv12028", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dc36d120-77b5-4b62-95f8-a90964499200"}}}}, {"uuid": "0c5bf3c3-b2bf-4b42-95ef-eb2a0f8846dd", "name": "", "x": 38.573586478514756, "y": -122.51990209164686, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fc4d79bb-8ba3-4146-9d50-16db48ffec22", "name": "p1rlv12157", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0c5bf3c3-b2bf-4b42-95ef-eb2a0f8846dd"}}}}, {"uuid": "b2724222-42d6-4b39-9bdc-a131b20c18d3", "name": "", "x": 38.61540289404265, "y": -122.4340916885271, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "751d2f2e-bb6f-4ca6-9e86-0e2b5ff3f92a", "name": "p1rdt5923lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b2724222-42d6-4b39-9bdc-a131b20c18d3"}}}}, {"uuid": "f3ca5954-1325-4b71-ab86-ab13dee31042", "name": "", "x": 38.615385277507826, "y": -122.43359039737986, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "df9d9de2-6929-48a4-a390-c0e2f129b374", "name": "p1rlv12214", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f3ca5954-1325-4b71-ab86-ab13dee31042"}}}}, {"uuid": "00db6112-34c3-46a6-abeb-4f179fbbd1a9", "name": "", "x": 38.615361354746774, "y": -122.43423382325552, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c4d26673-c304-41de-8b5b-149552601ba4", "name": "p1rlv12217", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "00db6112-34c3-46a6-abeb-4f179fbbd1a9"}}}}, {"uuid": "63fba15d-7056-4866-a483-76cfd4b7b3d1", "name": "", "x": 38.61582271842178, "y": -122.43459776600604, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cee79fe8-f140-4be9-aa6b-d56e37fb6857", "name": "p1rlv12222", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "63fba15d-7056-4866-a483-76cfd4b7b3d1"}}}}, {"uuid": "ef651d7a-fc6b-426f-b064-fc2e60a74988", "name": "", "x": 38.61514654148174, "y": -122.43395232342587, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e8e1f797-9417-447c-8a08-cf00a462ef14", "name": "p1rlv12225", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef651d7a-fc6b-426f-b064-fc2e60a74988"}}}}, {"uuid": "7c88c271-f3f6-45d4-9919-0e24699d4215", "name": "", "x": 38.586418831345604, "y": -122.50394128809963, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d654945d-b71d-4943-86a2-5830fca200c9", "name": "p1rdt6038lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7c88c271-f3f6-45d4-9919-0e24699d4215"}}}}, {"uuid": "ab853430-e034-4565-b98b-2589bd82df86", "name": "", "x": 38.58644635289331, "y": -122.50405591684549, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b42c2471-9114-4042-980e-dd226ad024a3", "name": "p1rlv12538", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ab853430-e034-4565-b98b-2589bd82df86"}}}}, {"uuid": "3d46fae0-0a33-4fd5-ac7e-6282cd5526e1", "name": "", "x": 38.583699762043224, "y": -122.50722384389097, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e5ae7bbf-f53e-4ae2-8145-bf56ce935094", "name": "p1rdt6043lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3d46fae0-0a33-4fd5-ac7e-6282cd5526e1"}}}}, {"uuid": "8037a8ee-3906-490a-9533-13016db8fd6c", "name": "", "x": 38.583590695705574, "y": -122.50712562826531, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4c42d772-e2a8-45d4-9cf2-2edd7a567b35", "name": "p1rlv12552", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8037a8ee-3906-490a-9533-13016db8fd6c"}}}}, {"uuid": "2aa9b7fa-506a-4f8c-8242-7ecbcfa25a2d", "name": "", "x": 38.58378667878022, "y": -122.50658466351123, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b3e53a11-6c13-4d27-89f2-2abbd28f69ac", "name": "p1rdm12875", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2aa9b7fa-506a-4f8c-8242-7ecbcfa25a2d"}}}}, {"uuid": "65da88d8-f338-4c87-9275-83b61c7bfc38", "name": "", "x": 38.58345266624825, "y": -122.50644917302039, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a29aec49-62a4-41ec-a67c-a84470a23f7b", "name": "p1rlv12553", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65da88d8-f338-4c87-9275-83b61c7bfc38"}}}}, {"uuid": "ea0e1728-da0c-415a-b2d8-63292335ef42", "name": "", "x": 38.58361036220623, "y": -122.50751586004849, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b748c697-b624-43f0-b375-5024d8cff92b", "name": "p1rdm12876", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea0e1728-da0c-415a-b2d8-63292335ef42"}}}}, {"uuid": "279d7791-7332-446f-84ff-965c7c9af534", "name": "", "x": 38.58369185365201, "y": -122.50760715446228, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75a47101-b6df-473e-9c7b-96e076c17931", "name": "p1rlv12559", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "279d7791-7332-446f-84ff-965c7c9af534"}}}}, {"uuid": "533b497d-f2b9-4c9a-b5d2-76e4e9c93a3c", "name": "", "x": 38.58357450876428, "y": -122.50756203032971, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3082eb6b-1a9f-4b6e-930e-f58173fe02ac", "name": "p1rdm12877", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "533b497d-f2b9-4c9a-b5d2-76e4e9c93a3c"}}}}, {"uuid": "efefb47a-9073-4b89-a2b8-7be8b197bb61", "name": "", "x": 38.58361995350426, "y": -122.5076535708703, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8b0417d3-820d-4daa-aec5-3dcf34e40e00", "name": "p1rlv12562", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "efefb47a-9073-4b89-a2b8-7be8b197bb61"}}}}, {"uuid": "6989f2f9-0ff1-40bd-a0b5-15527010b9ad", "name": "", "x": 38.583744918789954, "y": -122.50735404765867, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b2e2d1a7-039c-4b29-a061-b814ac675e3b", "name": "p1rdt6046lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6989f2f9-0ff1-40bd-a0b5-15527010b9ad"}}}}, {"uuid": "efcefbeb-719b-4ce3-b9ad-5d962103723a", "name": "", "x": 38.5839884657107, "y": -122.50742142633933, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4fe4d6ae-cca5-476c-981a-a1dcd27b1e84", "name": "p1rlv12557", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "efcefbeb-719b-4ce3-b9ad-5d962103723a"}}}}, {"uuid": "313e68dc-5043-4c00-aeb7-0a6788fddbe1", "name": "", "x": 38.5843554229652, "y": -122.50614844559887, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "21e75ccd-7e21-4f0d-890c-81aa6b33b109", "name": "p1rdt6047lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "313e68dc-5043-4c00-aeb7-0a6788fddbe1"}}}}, {"uuid": "a3824258-2643-48e3-8a13-8ebabaac90ac", "name": "", "x": 38.584325151037234, "y": -122.50605283115296, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0a427f20-861a-4616-9443-265beaeccca3", "name": "p1rlv12558", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a3824258-2643-48e3-8a13-8ebabaac90ac"}}}}, {"uuid": "1b8d5c33-b1ec-42d0-a6da-c5736badbefd", "name": "", "x": 38.605026243337974, "y": -122.47603639568145, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "01be483b-09f4-450e-a39d-78692c40ee8b", "name": "p1rdt6208lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1b8d5c33-b1ec-42d0-a6da-c5736badbefd"}}}}, {"uuid": "39d40bfc-7bc0-40d3-8121-d070af0c9f8b", "name": "", "x": 38.60501243846355, "y": -122.47608741299466, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "019e419c-9f88-455a-bf48-b89531ed9e51", "name": "p1rlv12936", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "39d40bfc-7bc0-40d3-8121-d070af0c9f8b"}}}}, {"uuid": "384d4ef5-af8c-43a0-a01a-b48e88a27593", "name": "", "x": 38.60004659977005, "y": -122.48124037604637, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "73f78740-2ec5-4ad8-b7fb-40f4a72b730e", "name": "p1rdt6221lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "384d4ef5-af8c-43a0-a01a-b48e88a27593"}}}}, {"uuid": "e8e66f12-8da3-41bd-b6fa-3dcac2ae471f", "name": "", "x": 38.60002062477275, "y": -122.48119777346218, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8418804f-aad5-49df-9916-f427da5089c1", "name": "p1rlv12959", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e8e66f12-8da3-41bd-b6fa-3dcac2ae471f"}}}}, {"uuid": "5aef84c3-b54b-424d-8ebe-45dc09d4dd79", "name": "", "x": 38.604436381862065, "y": -122.47563389239149, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3154eee7-a1ba-4b9d-9e91-bab55529d358", "name": "p1rdt6226lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5aef84c3-b54b-424d-8ebe-45dc09d4dd79"}}}}, {"uuid": "a4d56043-79b9-4411-b7b6-c7e551d90dfa", "name": "", "x": 38.604742034520584, "y": -122.47609857017211, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be845651-8e1c-4b6d-8633-fcbdfb1fd5d4", "name": "p1rlv12971", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a4d56043-79b9-4411-b7b6-c7e551d90dfa"}}}}, {"uuid": "2b9957d6-67cd-47ad-8f4b-d0ec588d795e", "name": "", "x": 38.60407996866283, "y": -122.47516164611108, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "646058a3-cda7-4723-bd0f-05d305fe7c11", "name": "p1rlv20185", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2b9957d6-67cd-47ad-8f4b-d0ec588d795e"}}}}, {"uuid": "459fe982-19fb-4fc7-937f-3429aa535d9f", "name": "", "x": 38.61627084774632, "y": -122.45497361088964, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "72ce0706-6b32-4b4b-9bf3-fd1f5a6af5ca", "name": "p1rdt6268lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "459fe982-19fb-4fc7-937f-3429aa535d9f"}}}}, {"uuid": "9667d696-5ea7-451e-9dd5-318e13202abf", "name": "", "x": 38.616595375163186, "y": -122.45499188425644, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3072c6c-3a40-4e49-bd00-febc8268b135", "name": "p1rlv13043", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9667d696-5ea7-451e-9dd5-318e13202abf"}}}}, {"uuid": "5b18d64b-c7b4-4e7f-b793-a467aa5f1eb0", "name": "", "x": 38.61557658935668, "y": -122.45489621541526, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4209bdad-276f-4e07-93e0-78b162ce95cf", "name": "p1rlv13047", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5b18d64b-c7b4-4e7f-b793-a467aa5f1eb0"}}}}, {"uuid": "f0178992-d931-4425-b1f8-6cf772629d45", "name": "", "x": 38.61659769116569, "y": -122.45488097254983, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "21c6ea4f-ec9d-424e-8743-7175408f9e2c", "name": "p1rlv13054", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f0178992-d931-4425-b1f8-6cf772629d45"}}}}, {"uuid": "cb47612f-823d-4fd9-b8da-f9f951b87220", "name": "", "x": 38.615484628332915, "y": -122.45948878298002, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "79c91fa8-15ad-4e8d-96bd-2cad395dd280", "name": "p1rdt6269lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb47612f-823d-4fd9-b8da-f9f951b87220"}}}}, {"uuid": "5f7b1184-1a50-4c3b-abc1-6f10d6b0e56b", "name": "", "x": 38.61545864547562, "y": -122.45944617926628, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fa31c772-8460-4624-a123-64b87ca8d332", "name": "p1rlv13044", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5f7b1184-1a50-4c3b-abc1-6f10d6b0e56b"}}}}, {"uuid": "e5f6f0cd-c468-47f3-8889-ba4631b16481", "name": "", "x": 38.61293890712679, "y": -122.45937135963467, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5adb2083-3d46-48a7-8996-37c0781b0215", "name": "p1rdt6270lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e5f6f0cd-c468-47f3-8889-ba4631b16481"}}}}, {"uuid": "d0437a27-08ad-41e0-a4a5-0be10eada9ba", "name": "", "x": 38.61312062731428, "y": -122.45970448051091, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6070414d-09e7-48a7-aec0-c105cc0f1a93", "name": "p1rlv13045", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d0437a27-08ad-41e0-a4a5-0be10eada9ba"}}}}, {"uuid": "a6648dc2-4180-476b-84b9-d71723671f17", "name": "", "x": 38.61305606107207, "y": -122.459383355912, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5edc15fb-49d5-4052-8fad-4979578f6ed1", "name": "p1rlv13046", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a6648dc2-4180-476b-84b9-d71723671f17"}}}}, {"uuid": "6e31ef12-0466-48cc-9ff0-19a2da1c50f8", "name": "", "x": 38.612568269488285, "y": -122.45913432583363, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "86d59550-d7c8-47e1-a6bc-14b2d50de58c", "name": "p1rlv13052", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6e31ef12-0466-48cc-9ff0-19a2da1c50f8"}}}}, {"uuid": "a27adeee-5e06-4c0b-935d-a908465d154f", "name": "", "x": 38.61201252826336, "y": -122.45742705644044, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1335e64c-9f37-4e73-a37f-8f76737cabff", "name": "p1rdt6271lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a27adeee-5e06-4c0b-935d-a908465d154f"}}}}, {"uuid": "e19ce3da-55ab-4c6b-ad4c-5f038c6b2ffb", "name": "", "x": 38.6124662872462, "y": -122.45657372759852, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "569078be-37c2-4c05-8455-91945eb7fdb9", "name": "p1rlv13048", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e19ce3da-55ab-4c6b-ad4c-5f038c6b2ffb"}}}}, {"uuid": "f6a8b3a9-1c2a-45e7-a53b-b1002f1822ad", "name": "", "x": 38.61056246852402, "y": -122.45546646876214, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "04422e0a-1952-422d-a201-5fafef1875db", "name": "p1rdt6272lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f6a8b3a9-1c2a-45e7-a53b-b1002f1822ad"}}}}, {"uuid": "d0a8d9b3-58c2-4f85-9b1b-a839988d3996", "name": "", "x": 38.61046043697304, "y": -122.45545178295872, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3ed85192-4c5a-4c15-ba21-1ba883b03ddd", "name": "p1rlv13049", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d0a8d9b3-58c2-4f85-9b1b-a839988d3996"}}}}, {"uuid": "170ec7fe-fcf7-4acf-b429-559cbeaf6976", "name": "", "x": 38.61065269092905, "y": -122.4554887580758, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e058437-0138-4305-a33e-d8fa61aed8cc", "name": "p1rlv13053", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "170ec7fe-fcf7-4acf-b429-559cbeaf6976"}}}}, {"uuid": "bc8f8b98-5280-45f9-8ac4-52ad1f005535", "name": "", "x": 38.61008611720184, "y": -122.45635048585197, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2b6739c0-1b15-42c1-9fdd-4d7f604a03ce", "name": "p1rdm13376", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bc8f8b98-5280-45f9-8ac4-52ad1f005535"}}}}, {"uuid": "68405c44-dbe2-4a6b-9268-accf72aead68", "name": "", "x": 38.61016439157834, "y": -122.45574115998643, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e9a855b0-538e-4fab-91f1-93b4ece09409", "name": "p1rlv13051", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "68405c44-dbe2-4a6b-9268-accf72aead68"}}}}, {"uuid": "e2efd60d-46ec-4832-9b23-6f31a690ecb5", "name": "", "x": 38.61026024108263, "y": -122.45636462882881, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b1db8c80-e791-4c31-a6f2-713aa665bf41", "name": "p1rdt6274lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e2efd60d-46ec-4832-9b23-6f31a690ecb5"}}}}, {"uuid": "cbd8342d-f215-4a5b-9bb6-d8f6f08670f7", "name": "", "x": 38.610392670089375, "y": -122.45638262926296, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e395985-4c66-49c9-9252-94d8078b8e8e", "name": "p1rdm13377", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cbd8342d-f215-4a5b-9bb6-d8f6f08670f7"}}}}, {"uuid": "4e8da740-8364-40d4-81e3-115c6cd3df80", "name": "", "x": 38.610432528075556, "y": -122.45587299013495, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16584dfd-537d-4b0d-a651-c73d0beabc6d", "name": "p1rlv13056", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4e8da740-8364-40d4-81e3-115c6cd3df80"}}}}, {"uuid": "fbf44c78-ce05-4b63-960e-76194f6ae49f", "name": "", "x": 38.610983387394924, "y": -122.45878265444647, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ba567584-fbee-44eb-b3f1-da24a0ce66a0", "name": "p1rdt6275lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fbf44c78-ce05-4b63-960e-76194f6ae49f"}}}}, {"uuid": "5111021a-6b72-40f1-b986-267d9c612a93", "name": "", "x": 38.61089111139205, "y": -122.45892869017909, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "387df3d3-5f03-47f4-8b16-bea8815e63d1", "name": "p1rlv13055", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5111021a-6b72-40f1-b986-267d9c612a93"}}}}, {"uuid": "b1bffdbe-f800-471c-a218-2352f3de7841", "name": "", "x": 38.611024903573316, "y": -122.45862905688004, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c83997dc-872f-494f-8c8a-7266c854fc48", "name": "p1rlv13058", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b1bffdbe-f800-471c-a218-2352f3de7841"}}}}, {"uuid": "8daf5a93-0aba-4efe-b6f8-87702fbd5e96", "name": "", "x": 38.61593370015664, "y": -122.45611332456588, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2f20ace2-5ec8-4451-b7e7-66f46c2c487b", "name": "p1rdt6276lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8daf5a93-0aba-4efe-b6f8-87702fbd5e96"}}}}, {"uuid": "cb93529c-6913-4fbe-a725-7e4dee686cdb", "name": "", "x": 38.616214343979955, "y": -122.45638463812467, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2c63d163-75bd-4d91-bcfa-229a2e331b1f", "name": "p1rlv13057", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb93529c-6913-4fbe-a725-7e4dee686cdb"}}}}, {"uuid": "ac857cdd-f51e-4fa1-9097-01222c65d188", "name": "", "x": 38.61560758048402, "y": -122.45574597720416, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8d2fa164-4c03-4bcd-a386-749ccd4e9001", "name": "p1rlv13062", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ac857cdd-f51e-4fa1-9097-01222c65d188"}}}}, {"uuid": "59b0c5c4-2dde-4be1-92d4-fc14c7f28bfc", "name": "", "x": 38.61608078908832, "y": -122.45806664881565, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e582b04d-a8d8-4ee9-8576-1e5941623c0b", "name": "p1rdt6277lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59b0c5c4-2dde-4be1-92d4-fc14c7f28bfc"}}}}, {"uuid": "ea6ecbce-6597-489c-806f-0b38415136ee", "name": "", "x": 38.616096280398985, "y": -122.45813147961287, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a1779b5b-1a6c-4511-9d4b-88026b430173", "name": "p1rlv13059", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea6ecbce-6597-489c-806f-0b38415136ee"}}}}, {"uuid": "b3dc1c19-d603-4d73-8550-c2b4745ed0ab", "name": "", "x": 38.616472312390336, "y": -122.45760251208678, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2b37eabc-787a-491f-bc4f-956f43a862ff", "name": "p1rdt6278lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b3dc1c19-d603-4d73-8550-c2b4745ed0ab"}}}}, {"uuid": "88ff6605-6274-48d5-a8df-b913f605e687", "name": "", "x": 38.61659895813833, "y": -122.45770269368248, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8767a040-da31-48d9-9473-0941856bcedc", "name": "p1rlv13060", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "88ff6605-6274-48d5-a8df-b913f605e687"}}}}, {"uuid": "d35605b8-f529-4dd5-ae8a-7cd432ad68bb", "name": "", "x": 38.635969271978226, "y": -122.41468609161443, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3a38eb6d-a625-42a1-95f6-bbf078d1447a", "name": "p1rdt6345lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d35605b8-f529-4dd5-ae8a-7cd432ad68bb"}}}}, {"uuid": "4016c322-b0a6-4180-bc76-3154deee1dad", "name": "", "x": 38.63598364556035, "y": -122.41473687445114, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c29c3206-b71d-41d1-8ad7-a693c8c25d4d", "name": "p1rlv13185", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4016c322-b0a6-4180-bc76-3154deee1dad"}}}}, {"uuid": "6cb57e62-5516-46bd-a1bd-16b0ff15d7fd", "name": "", "x": 38.638887372960305, "y": -122.42670366638174, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e40008af-ff50-42bd-8897-f663c27a436f", "name": "p1rdt6347lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6cb57e62-5516-46bd-a1bd-16b0ff15d7fd"}}}}, {"uuid": "e79a71dd-ab3c-4e4f-b0da-a0a3d2960fd9", "name": "", "x": 38.63887629434703, "y": -122.42675582564294, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ffbd17b6-b1a2-4e55-9052-67a84419bb9d", "name": "p1rlv13187", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e79a71dd-ab3c-4e4f-b0da-a0a3d2960fd9"}}}}, {"uuid": "effbfb8c-623e-49b9-a2a9-7c2b94ad9651", "name": "", "x": 38.63741237955581, "y": -122.41088141259655, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d84ac329-f314-41be-a2ee-89bc74789a18", "name": "p1rdt6348lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "effbfb8c-623e-49b9-a2a9-7c2b94ad9651"}}}}, {"uuid": "b0eb5a62-8284-4550-a2a3-f5fe56a755e1", "name": "", "x": 38.63776633109597, "y": -122.41081354844057, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "67ffcd9f-ba90-4da7-b3b6-46310e321590", "name": "p1rlv13188", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b0eb5a62-8284-4550-a2a3-f5fe56a755e1"}}}}, {"uuid": "05557a96-5314-4ed4-b7f0-eb914262c728", "name": "", "x": 38.63725354679822, "y": -122.41099009448936, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3f6d09e9-3592-4560-8626-0d7cb71ca56a", "name": "p1rlv13191", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "05557a96-5314-4ed4-b7f0-eb914262c728"}}}}, {"uuid": "6b814f18-4e8f-4dc6-a472-a092ced2af22", "name": "", "x": 38.63720762179658, "y": -122.41081812238316, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2e3e10c6-6ce2-4efa-be50-80e8b9bffe29", "name": "p1rlv13195", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6b814f18-4e8f-4dc6-a472-a092ced2af22"}}}}, {"uuid": "723dc179-b0d4-453a-a37d-3602709a2654", "name": "", "x": 38.63750552004759, "y": -122.4109190928234, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2cdd7c49-e758-4009-8db5-d0b5748f919c", "name": "p1rlv13201", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "723dc179-b0d4-453a-a37d-3602709a2654"}}}}, {"uuid": "855b9038-87f7-4d5d-b419-c8e7d259873c", "name": "", "x": 38.64190459200407, "y": -122.42077252919503, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fdfa0310-7dc5-4181-a64e-cc2522370547", "name": "p1rdt6349lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "855b9038-87f7-4d5d-b419-c8e7d259873c"}}}}, {"uuid": "a02fd54c-e29a-4c35-bbfb-ae25adf08bd4", "name": "", "x": 38.6420159229094, "y": -122.42084455001161, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "268361f6-d5ac-4002-80a6-f56f3b33599c", "name": "p1rlv13189", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a02fd54c-e29a-4c35-bbfb-ae25adf08bd4"}}}}, {"uuid": "06e6e604-e32f-43a8-a8e3-cb370f644ed3", "name": "", "x": 38.636198973427064, "y": -122.41018025968964, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0138b892-d18e-497c-9857-c4d5676deac2", "name": "p1rdt6350lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "06e6e604-e32f-43a8-a8e3-cb370f644ed3"}}}}, {"uuid": "1854b823-e587-42c6-9322-3428ce6ce9b2", "name": "", "x": 38.63617297274995, "y": -122.41013766183407, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3dbc593c-3949-4fa4-8738-d92540dbf998", "name": "p1rlv13190", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1854b823-e587-42c6-9322-3428ce6ce9b2"}}}}, {"uuid": "2166852d-80a3-428b-8d53-254aa32d4239", "name": "", "x": 38.634295860150814, "y": -122.41680227142706, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "015322ae-7712-488f-9569-33fc785e4f62", "name": "p1rdt6353lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2166852d-80a3-428b-8d53-254aa32d4239"}}}}, {"uuid": "7e881470-549e-48ee-adf6-abc91359e7f6", "name": "", "x": 38.634321357711805, "y": -122.41675918344534, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2d5ba889-d8f7-44ca-86b2-40939fa95df2", "name": "p1rlv13194", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7e881470-549e-48ee-adf6-abc91359e7f6"}}}}, {"uuid": "527d288f-2043-4812-9466-eedc4d8ab423", "name": "", "x": 38.63633728483974, "y": -122.42060300525114, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0fd10fd1-b67f-422c-b976-582e2bb4e0ec", "name": "p1rdm13558", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "527d288f-2043-4812-9466-eedc4d8ab423"}}}}, {"uuid": "1dca3f46-9489-4e6b-8c7c-ebe7d8fde286", "name": "", "x": 38.63688282698339, "y": -122.41975985681357, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "27013147-3d8f-4d75-a7a7-24457dc6d62a", "name": "p1rlv13196", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1dca3f46-9489-4e6b-8c7c-ebe7d8fde286"}}}}, {"uuid": "8cc62ace-11fa-4dd3-a1d9-b50e2ad0e7a0", "name": "", "x": 38.63646127576851, "y": -122.42073591122158, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f06a08bd-05ea-4914-b0d0-07cd0e83bfbc", "name": "p1rdt6354lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8cc62ace-11fa-4dd3-a1d9-b50e2ad0e7a0"}}}}, {"uuid": "c604b145-f503-41b1-9dc4-2f31cad75e9b", "name": "", "x": 38.63663597134643, "y": -122.42086486559913, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "786efaf4-c281-4def-9a4e-2ffbf37e08be", "name": "p1rdm13559", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c604b145-f503-41b1-9dc4-2f31cad75e9b"}}}}, {"uuid": "a95d2d49-eb75-4e81-a97c-4fd013ac2e53", "name": "", "x": 38.63697733189416, "y": -122.42007329323263, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fed30a3f-12a5-4545-b5d5-5c13a131a256", "name": "p1rlv13200", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a95d2d49-eb75-4e81-a97c-4fd013ac2e53"}}}}, {"uuid": "a8acb079-e050-43db-b97d-4a7c0aed2fdf", "name": "", "x": 38.64208811872309, "y": -122.42143750947257, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f1d14a79-4d18-43fe-8790-57ea9adf83a8", "name": "p1rdt6355lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8acb079-e050-43db-b97d-4a7c0aed2fdf"}}}}, {"uuid": "ecb37bad-3593-475c-827e-ec4e7777c96f", "name": "", "x": 38.64203661805849, "y": -122.42138444352005, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7b077d0f-74ec-4a04-8eb8-cf02ad16077d", "name": "p1rlv13197", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ecb37bad-3593-475c-827e-ec4e7777c96f"}}}}, {"uuid": "76c93f4d-c02a-44ff-b4b5-6f417c2b54a4", "name": "", "x": 38.637121227961, "y": -122.41980119772418, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "548724aa-110a-428f-b71a-acdf0051dc39", "name": "p1rdt6356lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "76c93f4d-c02a-44ff-b4b5-6f417c2b54a4"}}}}, {"uuid": "a6b8ea32-a985-4859-ab59-f6d7b0d0da63", "name": "", "x": 38.6370952307597, "y": -122.41975859580664, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ad7545fb-8a41-4ed7-a178-e90f19bfa9d5", "name": "p1rlv13199", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a6b8ea32-a985-4859-ab59-f6d7b0d0da63"}}}}, {"uuid": "ddfdec26-8ee3-49e0-9a72-cb7236e92342", "name": "", "x": 38.625625701122225, "y": -122.46597233146389, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e36cfaaa-3996-4cc6-aa4f-170f20c5d1e0", "name": "p1rdt6409lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ddfdec26-8ee3-49e0-9a72-cb7236e92342"}}}}, {"uuid": "b2a436d9-b0f8-48e2-aeb6-3e0d1f57befc", "name": "", "x": 38.625599720610666, "y": -122.46592971942587, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "473b080b-1412-40dc-a452-09d43a462098", "name": "p1rlv13316", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b2a436d9-b0f8-48e2-aeb6-3e0d1f57befc"}}}}, {"uuid": "0b946f90-2e39-4fd3-b0ba-8544c409d55c", "name": "", "x": 38.578857638178405, "y": -122.51077785799649, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7", "name": "p1rdt6498lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0b946f90-2e39-4fd3-b0ba-8544c409d55c"}}}}, {"uuid": "1d821ba2-72a7-4d64-b2d1-a334142c0759", "name": "", "x": 38.57893830123369, "y": -122.5108886242969, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "353889fb-da44-4cf8-ae0e-d20541f36d7e", "name": "p1rlv13597", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d821ba2-72a7-4d64-b2d1-a334142c0759"}}}}, {"uuid": "467c88e4-d134-4fa8-9e81-73a5a3be69ab", "name": "", "x": 38.57885671632947, "y": -122.51077437155158, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6015a810-79da-480f-b1a1-fd6a4abdba37", "name": "p1rlv13631", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "467c88e4-d134-4fa8-9e81-73a5a3be69ab"}}}}, {"uuid": "d9c52a80-2697-4d5e-914c-a915bfd7285f", "name": "", "x": 38.579117623107756, "y": -122.51066927591476, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f92273c9-90b8-4819-b036-9d69afb5aed6", "name": "p1rlv13696", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d9c52a80-2697-4d5e-914c-a915bfd7285f"}}}}, {"uuid": "b7b04bac-1b23-4b18-bc24-f9ee42054770", "name": "", "x": 38.57882896139523, "y": -122.51060235083729, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1fe3c958-296f-4b51-8b2b-74bb34ddb5a6", "name": "p1rlv13702", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b7b04bac-1b23-4b18-bc24-f9ee42054770"}}}}, {"uuid": "9aaf3362-751e-4e7d-ab80-e0243d0b72f8", "name": "", "x": 38.578814411150496, "y": -122.51075566702022, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c9efacf5-5b96-4670-b6f1-dc398485cde9", "name": "p1rlv13703", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9aaf3362-751e-4e7d-ab80-e0243d0b72f8"}}}}, {"uuid": "1d16ca37-4d9e-4caa-adb7-d56ca9da816a", "name": "", "x": 38.57878534253772, "y": -122.51094706458596, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "457c6c9d-5020-4cf3-9c1e-c36012a619d2", "name": "p1rlv13724", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d16ca37-4d9e-4caa-adb7-d56ca9da816a"}}}}, {"uuid": "8390b3b1-225b-4c6a-896a-3fb330512d9c", "name": "", "x": 38.58016810697636, "y": -122.51189059526916, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ce39f1f5-b784-4919-9d3d-f6149f39595e", "name": "p1rdm13996", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8390b3b1-225b-4c6a-896a-3fb330512d9c"}}}}, {"uuid": "7d953cf8-edae-40e4-91a0-6f7cb240f34b", "name": "", "x": 38.5798974214499, "y": -122.5118120619195, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "59953c2f-244e-4bb8-ab24-b28d82b195e1", "name": "p1rlv13598", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7d953cf8-edae-40e4-91a0-6f7cb240f34b"}}}}, {"uuid": "93963b59-7c3d-4dd6-ac3e-0ad59a026255", "name": "", "x": 38.57980967492142, "y": -122.51170181808382, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aeea20e0-9908-4f28-aa5d-068244e3861b", "name": "p1rlv13626", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "93963b59-7c3d-4dd6-ac3e-0ad59a026255"}}}}, {"uuid": "1ad6b39f-4277-41f1-9a59-2045f78b2e42", "name": "", "x": 38.57989689465763, "y": -122.51168577702153, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cc33013a-6a90-46a7-9127-f32288111c14", "name": "p1rlv13635", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1ad6b39f-4277-41f1-9a59-2045f78b2e42"}}}}, {"uuid": "5eeeb5e6-f8c4-4529-a6ba-bfc863eb4f1e", "name": "", "x": 38.579743504522455, "y": -122.51164089263591, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7b3e7495-7732-42ce-8d53-a5f1b7383ce4", "name": "p1rlv20504", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5eeeb5e6-f8c4-4529-a6ba-bfc863eb4f1e"}}}}, {"uuid": "c3a02a5e-5c58-4beb-a733-0ec716c360ff", "name": "", "x": 38.5802287989983, "y": -122.5117616084684, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bb05d831-1556-4f56-8065-d9d16657caa3", "name": "p1rdt6499lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c3a02a5e-5c58-4beb-a733-0ec716c360ff"}}}}, {"uuid": "a99ef52b-4365-4bea-9c0d-269b26323d76", "name": "", "x": 38.58030555227583, "y": -122.51158054354175, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f85240e6-bbbe-4b90-8419-a00a3ca9613f", "name": "p1rdm13999", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a99ef52b-4365-4bea-9c0d-269b26323d76"}}}}, {"uuid": "3faf2268-1c3c-4bf5-bd88-7c9001bd6c12", "name": "", "x": 38.57988706857757, "y": -122.51149067050049, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3839c291-3f45-46c3-973f-6a9615fcf81b", "name": "p1rlv13698", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3faf2268-1c3c-4bf5-bd88-7c9001bd6c12"}}}}, {"uuid": "149c7dea-71cc-4482-83fc-8194d3d50a88", "name": "", "x": 38.58035293960693, "y": -122.51140410649425, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ea740eb8-42c6-4417-97d6-7c73f1fc2bc8", "name": "p1rdm14000", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "149c7dea-71cc-4482-83fc-8194d3d50a88"}}}}, {"uuid": "108611d9-9d63-47a3-aae9-ef2cdacf6787", "name": "", "x": 38.580220356921046, "y": -122.5114539704366, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "642597e6-fe60-442f-b356-2be6f21677b2", "name": "p1rlv13726", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "108611d9-9d63-47a3-aae9-ef2cdacf6787"}}}}, {"uuid": "17774d75-030e-4f6b-b9fc-a5ea4e90bb77", "name": "", "x": 38.58083948102145, "y": -122.5097420033343, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a20a4242-8a76-49f3-9bf5-3d7aaf751cdc", "name": "p1rdt6500lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "17774d75-030e-4f6b-b9fc-a5ea4e90bb77"}}}}, {"uuid": "fca68e74-8079-476d-8e08-9403ecc91752", "name": "", "x": 38.58075318348773, "y": -122.50956749241811, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "216537dd-ea7b-461c-b821-99491c41b7f0", "name": "p1rlv13613", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fca68e74-8079-476d-8e08-9403ecc91752"}}}}, {"uuid": "946b4384-4111-4b9d-baa0-3d02c5634209", "name": "", "x": 38.58094565510626, "y": -122.50948667802179, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "83aa4266-e486-4e00-a09b-7bcdc613a9b5", "name": "p1rdm14004", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "946b4384-4111-4b9d-baa0-3d02c5634209"}}}}, {"uuid": "98f2af76-03e7-4ca3-8482-85d5bb432b8c", "name": "", "x": 38.580815639747385, "y": -122.50941781578797, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f823a90c-effd-489c-9e0a-c110ccb7b9e8", "name": "p1rlv13618", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "98f2af76-03e7-4ca3-8482-85d5bb432b8c"}}}}, {"uuid": "273b3d0e-7740-4807-828e-a1e37aa9d0e9", "name": "", "x": 38.58094199565767, "y": -122.50946287997223, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ff282b99-30bb-4c1d-acb9-02fafe241577", "name": "p1rdm14007", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "273b3d0e-7740-4807-828e-a1e37aa9d0e9"}}}}, {"uuid": "43d3fb88-4440-485a-a7d4-1cfa651312fb", "name": "", "x": 38.580561868772826, "y": -122.50907511585717, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1c61a243-7736-46a0-a950-7cc811381158", "name": "p1rlv13653", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "43d3fb88-4440-485a-a7d4-1cfa651312fb"}}}}, {"uuid": "57b109ad-77d4-4e35-8c6a-2d1b67884755", "name": "", "x": 38.58103524253283, "y": -122.50935977822509, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3c0ae3b1-ac0d-43c9-9a1e-c73bd10e3ad8", "name": "p1rdm14002", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "57b109ad-77d4-4e35-8c6a-2d1b67884755"}}}}, {"uuid": "974a1a48-d33c-48aa-aeb5-230ce3105a1c", "name": "", "x": 38.58069699573112, "y": -122.50906271510544, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d2a60818-4310-4100-9aa8-35ef37aa5f40", "name": "p1rlv13599", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "974a1a48-d33c-48aa-aeb5-230ce3105a1c"}}}}, {"uuid": "fabd8bb6-7edf-42be-8e6b-5663ec1f9863", "name": "", "x": 38.58115055848325, "y": -122.50921129101727, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d576dffc-af75-488e-8c51-19aa726f0505", "name": "p1rdm14005", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fabd8bb6-7edf-42be-8e6b-5663ec1f9863"}}}}, {"uuid": "631cb3f9-1cef-4bac-96dc-ab0058dd06c9", "name": "", "x": 38.58066046743406, "y": -122.50894815487301, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "62a29ac5-7227-43b2-b602-b1189cc93839", "name": "p1rlv13648", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "631cb3f9-1cef-4bac-96dc-ab0058dd06c9"}}}}, {"uuid": "e50ab3f8-8db4-47ab-851d-95ec1d4566e7", "name": "", "x": 38.58075404919642, "y": -122.50977414282289, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7e5abf33-75a2-446f-9c6c-1f3384b78c24", "name": "p1rdm14008", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e50ab3f8-8db4-47ab-851d-95ec1d4566e7"}}}}, {"uuid": "45f7226f-8189-4fdd-986c-9f3171a508b2", "name": "", "x": 38.58080831157611, "y": -122.50981969761952, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4671f981-e26e-4f26-9698-7f9068ce6dec", "name": "p1rlv13687", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "45f7226f-8189-4fdd-986c-9f3171a508b2"}}}}, {"uuid": "4690aac7-835d-4f30-ae06-41a51aaf2b24", "name": "", "x": 38.580709327387154, "y": -122.50985481311328, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "592b8095-ba99-4993-a445-9af51fa89f57", "name": "p1rdm14009", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4690aac7-835d-4f30-ae06-41a51aaf2b24"}}}}, {"uuid": "c77d28e1-b011-4ecc-a915-17583b1adf98", "name": "", "x": 38.580745614457776, "y": -122.50991197100555, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "44aa3f37-e0db-4050-b47f-ac14b7fa6534", "name": "p1rlv13719", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c77d28e1-b011-4ecc-a915-17583b1adf98"}}}}, {"uuid": "810ea90d-e32b-4403-a753-626d87d2255b", "name": "", "x": 38.58065559384605, "y": -122.50993554454202, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33445b16-68bf-4606-8ac5-def4763fb95d", "name": "p1rdm14006", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "810ea90d-e32b-4403-a753-626d87d2255b"}}}}, {"uuid": "8cb81b56-81c0-4541-bf0e-8d99301e93e7", "name": "", "x": 38.58069192894027, "y": -122.51000418300181, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3310c14a-d1ee-4d0c-8428-d002703c61d5", "name": "p1rlv13652", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8cb81b56-81c0-4541-bf0e-8d99301e93e7"}}}}, {"uuid": "d5eb11ec-20a7-43a6-bcbe-8e80506573b5", "name": "", "x": 38.580115053283016, "y": -122.51211138251598, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923", "name": "p1rdt6501lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d5eb11ec-20a7-43a6-bcbe-8e80506573b5"}}}}, {"uuid": "e0c5a120-ac0a-43a9-80c0-9d910c4b0d14", "name": "", "x": 38.57996098198724, "y": -122.5119264394613, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "59ab6d81-a91c-4350-8f94-abe02e3e1555", "name": "p1rlv13600", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e0c5a120-ac0a-43a9-80c0-9d910c4b0d14"}}}}, {"uuid": "c9ff9645-8f59-4b3a-b2b6-f8365fc0a052", "name": "", "x": 38.58025012153835, "y": -122.51210817586814, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "29838633-5c95-4b73-8227-cfa7f4aedc32", "name": "p1rlv13606", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c9ff9645-8f59-4b3a-b2b6-f8365fc0a052"}}}}, {"uuid": "b28ac41e-68ec-478f-8f63-b7474b7cb521", "name": "", "x": 38.58018699193046, "y": -122.51209712213534, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a5e8caf4-4d81-4bbd-98df-6622c5ad0563", "name": "p1rlv13608", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b28ac41e-68ec-478f-8f63-b7474b7cb521"}}}}, {"uuid": "a75547f7-63ae-4c46-88ef-c390878cd28c", "name": "", "x": 38.580430450820984, "y": -122.5121299176103, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f693a1d2-5499-4810-9458-f205eda265fa", "name": "p1rlv13619", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a75547f7-63ae-4c46-88ef-c390878cd28c"}}}}, {"uuid": "36b4f113-3755-49cf-8d87-c2a79648b0d1", "name": "", "x": 38.58039473905232, "y": -122.51221052513978, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4540b2cb-ee21-4515-a7ca-fbca371f060d", "name": "p1rlv13622", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "36b4f113-3755-49cf-8d87-c2a79648b0d1"}}}}, {"uuid": "b1b116f3-0151-42b2-a8aa-ac02307e8906", "name": "", "x": 38.57999120125346, "y": -122.51201057019674, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "30c470ac-39d1-4379-9ae7-790d912bce2c", "name": "p1rlv13637", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b1b116f3-0151-42b2-a8aa-ac02307e8906"}}}}, {"uuid": "0870751c-5e1a-47c1-ab38-434e9da36a6c", "name": "", "x": 38.580262816627275, "y": -122.51171636414, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0b7d4c6f-98b5-4cec-b8a4-9311b5fc92bd", "name": "p1rdm14016", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0870751c-5e1a-47c1-ab38-434e9da36a6c"}}}}, {"uuid": "1221665c-1324-49ea-93f7-2780a566c268", "name": "", "x": 38.58050168270344, "y": -122.5119227801456, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "de45dc59-3e0a-4b33-8cf4-d5213b0140c1", "name": "p1rlv13683", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1221665c-1324-49ea-93f7-2780a566c268"}}}}, {"uuid": "16be71f9-5715-4ab6-8469-27d24af8c118", "name": "", "x": 38.58090324022768, "y": -122.51898480487121, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7682e9f7-1272-4781-b128-34c7329afe49", "name": "p1rdt6502lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "16be71f9-5715-4ab6-8469-27d24af8c118"}}}}, {"uuid": "a8cffd85-3289-411b-aba3-fe19b3957850", "name": "", "x": 38.5809550747074, "y": -122.51912974155378, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "91953a27-bbc7-494a-bec2-a12b4c0f6af6", "name": "p1rlv13601", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8cffd85-3289-411b-aba3-fe19b3957850"}}}}, {"uuid": "d1656f14-981b-475f-950b-06cfa738b307", "name": "", "x": 38.580818625476454, "y": -122.51882066658119, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "987b05d5-9bb9-434d-98b3-623ee5014870", "name": "p1rlv13634", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1656f14-981b-475f-950b-06cfa738b307"}}}}, {"uuid": "576e3987-1203-4abc-b2aa-d321607a4c09", "name": "", "x": 38.579472359669175, "y": -122.51077416509521, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "387e7785-8d40-4ddd-8c2b-14a83d4e7401", "name": "p1rdt6505lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "576e3987-1203-4abc-b2aa-d321607a4c09"}}}}, {"uuid": "117edca2-b846-4d13-9e09-6fbfb439c0a0", "name": "", "x": 38.579542563399, "y": -122.5109993333898, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c9b83bdf-b564-4997-bfc7-1be2f2e58199", "name": "p1rlv13604", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "117edca2-b846-4d13-9e09-6fbfb439c0a0"}}}}, {"uuid": "ee47ad29-c529-4e7b-a7dd-b2020a1a2885", "name": "", "x": 38.579306628363845, "y": -122.51061059015836, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c39dc6f1-08b5-4bc1-a6ae-be0076af56aa", "name": "p1rlv13605", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ee47ad29-c529-4e7b-a7dd-b2020a1a2885"}}}}, {"uuid": "0dec7af5-bd71-4eb9-b72c-26a08ebea42c", "name": "", "x": 38.57932426767413, "y": -122.51051862504016, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a7be734c-88e2-42c1-8061-f4632bd05759", "name": "p1rlv13654", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0dec7af5-bd71-4eb9-b72c-26a08ebea42c"}}}}, {"uuid": "2116346b-bc4a-4280-8b61-ba47b65fca49", "name": "", "x": 38.57968631853392, "y": -122.51089503204967, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8df1a69e-5b18-4eef-ab60-543a97257297", "name": "p1rlv13676", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2116346b-bc4a-4280-8b61-ba47b65fca49"}}}}, {"uuid": "e3d45cb8-548e-48b2-8d6b-213cd2b0dc2e", "name": "", "x": 38.579406764605274, "y": -122.51085100517132, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a822fdb0-b531-49b0-89da-b517e5ae6e3a", "name": "p1rlv13715", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e3d45cb8-548e-48b2-8d6b-213cd2b0dc2e"}}}}, {"uuid": "b166c449-a23e-4a12-b4cc-82d2661db536", "name": "", "x": 38.57531283222509, "y": -122.51744138284937, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f5844baa-5e0f-4edd-9122-fe4255adad0b", "name": "p1rdt6507lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b166c449-a23e-4a12-b4cc-82d2661db536"}}}}, {"uuid": "5eb22c70-3464-4dba-a0ef-ad656df3001f", "name": "", "x": 38.57505206910961, "y": -122.5168960568265, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "17d92377-b4f1-4194-89cd-130bddb9b77c", "name": "p1rlv13610", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5eb22c70-3464-4dba-a0ef-ad656df3001f"}}}}, {"uuid": "09e5d099-7b4a-4e2d-b26a-9262b490061d", "name": "", "x": 38.57545948963316, "y": -122.51735253068708, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5a2f5fad-c0a9-4f62-a318-ef00c0d4f470", "name": "p1rdm14031", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "09e5d099-7b4a-4e2d-b26a-9262b490061d"}}}}, {"uuid": "143b6497-07f4-4643-9cde-7468e190cad4", "name": "", "x": 38.57508745244601, "y": -122.5167350997636, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e5ab8bce-7c02-4c7b-962e-3fb44a3ab7a9", "name": "p1rlv13712", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "143b6497-07f4-4643-9cde-7468e190cad4"}}}}, {"uuid": "90a1cfbd-701d-4453-a895-51357736c657", "name": "", "x": 38.58028384394968, "y": -122.51110778698562, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5", "name": "p1rdt6508lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "90a1cfbd-701d-4453-a895-51357736c657"}}}}, {"uuid": "86ae937a-a60c-4ae1-a7c8-387f40e1eb91", "name": "", "x": 38.58035447758333, "y": -122.51120048333938, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "630b2a63-622f-4f78-8390-77c69ba7e393", "name": "p1rlv13611", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "86ae937a-a60c-4ae1-a7c8-387f40e1eb91"}}}}, {"uuid": "56eecfee-9e33-4531-a77b-2f2f7c11b0b4", "name": "", "x": 38.58037206939203, "y": -122.51109703650175, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5868c24b-2a58-459b-8650-a6072241aca8", "name": "p1rlv13666", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "56eecfee-9e33-4531-a77b-2f2f7c11b0b4"}}}}, {"uuid": "061c6dbf-e40a-4035-a3a4-ba8cb2fe1a04", "name": "", "x": 38.57994856849807, "y": -122.51111138826255, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f777bc74-e6f3-4e80-bb72-0764964db21e", "name": "p1rlv13685", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "061c6dbf-e40a-4035-a3a4-ba8cb2fe1a04"}}}}, {"uuid": "f562c711-b88d-409b-8e2e-eb3672b70456", "name": "", "x": 38.58024590590882, "y": -122.51109789179142, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aa7a324e-d367-49a5-820a-b18e72243265", "name": "p1rlv13701", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f562c711-b88d-409b-8e2e-eb3672b70456"}}}}, {"uuid": "2d927b29-01ab-4d50-a650-33eccd1a79d9", "name": "", "x": 38.5799747881709, "y": -122.51091603723427, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "286623b3-af08-4a60-896a-1f5b85fe04a5", "name": "p1rlv13707", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2d927b29-01ab-4d50-a650-33eccd1a79d9"}}}}, {"uuid": "063db81f-f1ad-43f7-88ab-eff9687a417b", "name": "", "x": 38.58041348455226, "y": -122.51100123505434, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "572123ef-d255-42a9-9c61-95d99aaff775", "name": "p1rdm14033", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "063db81f-f1ad-43f7-88ab-eff9687a417b"}}}}, {"uuid": "61501da2-c1a2-4b94-b083-88cfce749eb4", "name": "", "x": 38.58026296994941, "y": -122.51086815956218, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c808261e-a49e-4954-bdc4-a8b63d0ee25b", "name": "p1rlv13651", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "61501da2-c1a2-4b94-b083-88cfce749eb4"}}}}, {"uuid": "4b2e985c-70d7-4dd4-a2d1-1e17ef074d29", "name": "", "x": 38.58047071823679, "y": -122.5109815591307, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9657a993-0005-4ffc-8c9f-18e80a491070", "name": "p1rlv13728", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4b2e985c-70d7-4dd4-a2d1-1e17ef074d29"}}}}, {"uuid": "b204f9a6-7874-4654-b240-9f95ec20a3a3", "name": "", "x": 38.5802039677474, "y": -122.51142297137118, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f817a28f-c650-4eb4-84c0-751fe5053c75", "name": "p1rdt6509lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b204f9a6-7874-4654-b240-9f95ec20a3a3"}}}}, {"uuid": "3d63084b-d34f-45cc-acbb-fd7c7f5a12e0", "name": "", "x": 38.58031071328429, "y": -122.51151076251458, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6eda3e97-a618-41ab-ae55-ba67f6bb0234", "name": "p1rlv13612", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3d63084b-d34f-45cc-acbb-fd7c7f5a12e0"}}}}, {"uuid": "6497e293-e1f6-435a-bce1-81d85ff0cc34", "name": "", "x": 38.58038280670725, "y": -122.51151027418985, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e47df44a-79f1-423b-a295-c9c354795895", "name": "p1rlv13628", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6497e293-e1f6-435a-bce1-81d85ff0cc34"}}}}, {"uuid": "1c58cbeb-4ec0-4ca2-ac37-c2b219acb7ac", "name": "", "x": 38.58025300210597, "y": -122.51162119713781, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b65a5fd-f38e-447a-a51a-e7a214ba6bcc", "name": "p1rdm14041", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1c58cbeb-4ec0-4ca2-ac37-c2b219acb7ac"}}}}, {"uuid": "fde75755-8187-4131-a5d4-4019004aa484", "name": "", "x": 38.580112887543876, "y": -122.51161542971188, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3bd69c55-2141-4c8e-becf-efa4bff8a63e", "name": "p1rlv13627", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fde75755-8187-4131-a5d4-4019004aa484"}}}}, {"uuid": "e4998f27-5b4d-4c16-ab05-f4dac5151539", "name": "", "x": 38.580175969292135, "y": -122.51161500252242, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "122e0772-7de6-4117-b1d3-caafbbbc8e22", "name": "p1rlv13659", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e4998f27-5b4d-4c16-ab05-f4dac5151539"}}}}, {"uuid": "b4d08695-c287-4103-a10a-c5f5e7de9242", "name": "", "x": 38.58035042352862, "y": -122.51170963762122, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3d6fd13-2f04-4f23-97a3-cdf99159174c", "name": "p1rlv13660", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b4d08695-c287-4103-a10a-c5f5e7de9242"}}}}, {"uuid": "d88a5ec5-7a6d-401d-9412-e96155fdde62", "name": "", "x": 38.58048939096295, "y": -122.51181556577525, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f9aa7e62-8974-4ef0-aa5a-bcd545245aea", "name": "p1rlv13677", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d88a5ec5-7a6d-401d-9412-e96155fdde62"}}}}, {"uuid": "75d80de5-97ee-4db0-a01b-be74d82659b4", "name": "", "x": 38.58024561739162, "y": -122.51180603102428, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1252c522-5ced-4f4c-908c-f58501ad6f92", "name": "p1rdm14040", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "75d80de5-97ee-4db0-a01b-be74d82659b4"}}}}, {"uuid": "72b5ddf0-cdde-4895-9453-c7f24c784a2d", "name": "", "x": 38.580128349144296, "y": -122.51168024007933, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a5746d1-24a6-4ae4-b5dc-cef23b56660d", "name": "p1rlv13624", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "72b5ddf0-cdde-4895-9453-c7f24c784a2d"}}}}, {"uuid": "bd429e21-2c9a-44b9-8545-365dc7b0f4b3", "name": "", "x": 38.580312054434806, "y": -122.51183221682473, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6097c903-70fc-4635-a66c-fee2243ba545", "name": "p1rlv13721", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bd429e21-2c9a-44b9-8545-365dc7b0f4b3"}}}}, {"uuid": "8afa5cca-cf73-4ba5-8115-0096b37ddc9f", "name": "", "x": 38.580296766700286, "y": -122.51131091827517, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9be8942c-8459-4c1d-a3b0-a89ee5cced4e", "name": "p1rdm14043", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8afa5cca-cf73-4ba5-8115-0096b37ddc9f"}}}}, {"uuid": "29f2bebe-42ef-47a3-a9af-271923a11423", "name": "", "x": 38.5799938666379, "y": -122.51116848511225, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2b3fe33f-fdcf-42f5-be08-8da15a4d4958", "name": "p1rlv13633", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "29f2bebe-42ef-47a3-a9af-271923a11423"}}}}, {"uuid": "c53689db-2b77-4c25-b14e-1fb5d913ade2", "name": "", "x": 38.5799041333983, "y": -122.51126093949996, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "54887ca7-ae23-42d0-a715-aed8baa38ade", "name": "p1rlv13663", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c53689db-2b77-4c25-b14e-1fb5d913ade2"}}}}, {"uuid": "9ab32b8a-c150-4705-a799-5d52c7489517", "name": "", "x": 38.580282671809215, "y": -122.5112698550077, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32bec8ad-b312-4502-a2a1-6a4c9b2dd87a", "name": "p1rlv13672", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9ab32b8a-c150-4705-a799-5d52c7489517"}}}}, {"uuid": "36454f81-98b1-4198-a09a-d38e5d78e1a2", "name": "", "x": 38.58020166258251, "y": -122.51129336562714, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60fe0a16-aa4d-4fe8-9f39-81bfa13b505f", "name": "p1rlv13686", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "36454f81-98b1-4198-a09a-d38e5d78e1a2"}}}}, {"uuid": "0a18e2cb-16df-4c1c-81b6-dbb05c76fbe1", "name": "", "x": 38.57904493503404, "y": -122.51120538916284, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5d62fe3b-7644-46d1-8a15-e86d95ae8b2a", "name": "p1rdt6510lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a18e2cb-16df-4c1c-81b6-dbb05c76fbe1"}}}}, {"uuid": "f3325332-f006-4607-a16a-4f00a69b75f0", "name": "", "x": 38.5789032137621, "y": -122.51111847447159, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3de8b994-01ba-4eae-b9cf-7fb174d32355", "name": "p1rlv13614", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f3325332-f006-4607-a16a-4f00a69b75f0"}}}}, {"uuid": "ba7db288-60ce-4c65-a595-a56e7f503a45", "name": "", "x": 38.5791652716089, "y": -122.51128890787042, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "85b910cd-def8-41d8-ad47-3c074a54ad8d", "name": "p1rlv13680", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ba7db288-60ce-4c65-a595-a56e7f503a45"}}}}, {"uuid": "82223b46-a986-42df-938c-4dbe70b435f8", "name": "", "x": 38.57913785305847, "y": -122.51119724847887, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "58e2b774-ac04-435e-9e03-573b3aa94cfb", "name": "p1rlv20467", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "82223b46-a986-42df-938c-4dbe70b435f8"}}}}, {"uuid": "50b458e0-d55c-4e4a-843a-96e5759c930a", "name": "", "x": 38.58046789565426, "y": -122.5107496740826, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5702c88a-92e4-40ce-8a51-684fe6662789", "name": "p1rdt6512lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "50b458e0-d55c-4e4a-843a-96e5759c930a"}}}}, {"uuid": "cd9c9ac2-fe35-4dc5-99b4-d2982e164998", "name": "", "x": 38.58036118662805, "y": -122.51064935740038, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "850d5b69-14cf-4a18-8cb0-4f1b3033b0aa", "name": "p1rlv13616", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cd9c9ac2-fe35-4dc5-99b4-d2982e164998"}}}}, {"uuid": "3ebbb7c2-14b8-4efd-a122-9e8fedbeb88b", "name": "", "x": 38.58035246292223, "y": -122.510718301644, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "20009de0-cbe7-4b4f-a046-425a6ae71925", "name": "p1rlv13643", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3ebbb7c2-14b8-4efd-a122-9e8fedbeb88b"}}}}, {"uuid": "4bb71e49-0e3e-4855-95cd-ac756bef5eca", "name": "", "x": 38.58049679372011, "y": -122.51075176502394, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3fe0466e-cce5-4c6c-b13f-cedd349b6944", "name": "p1rlv13646", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4bb71e49-0e3e-4855-95cd-ac756bef5eca"}}}}, {"uuid": "6c71be1f-dd4f-4c0a-9aba-36a2ddb80c23", "name": "", "x": 38.5801239858384, "y": -122.51063551633443, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3fa2041e-34c4-4f1f-a329-74969c3da75f", "name": "p1rlv13650", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c71be1f-dd4f-4c0a-9aba-36a2ddb80c23"}}}}, {"uuid": "26581ec2-f996-4c6a-944b-6969311a7b5b", "name": "", "x": 38.580207508083255, "y": -122.510535591989, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e290046b-c936-4f51-b4ef-632bf572ab7f", "name": "p1rlv13725", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "26581ec2-f996-4c6a-944b-6969311a7b5b"}}}}, {"uuid": "91b7f1e8-60ef-4282-9431-17ad4a4ed438", "name": "", "x": 38.580513953094915, "y": -122.51054499300294, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e3ed4387-9ecb-43c4-a392-e72bc5cb32b6", "name": "p1rdm14062", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "91b7f1e8-60ef-4282-9431-17ad4a4ed438"}}}}, {"uuid": "bff6a849-e000-42dd-a1ca-7d6cef0fe830", "name": "", "x": 38.580216231682456, "y": -122.51046664786318, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "70cf02cc-8f1b-48ab-b9e6-50c3e58ad9ae", "name": "p1rlv13664", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bff6a849-e000-42dd-a1ca-7d6cef0fe830"}}}}, {"uuid": "5fd72616-7318-4cb3-8643-7fa32865504e", "name": "", "x": 38.58042383633111, "y": -122.5105456046176, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60f08cde-51d3-4b51-9ab5-b61c8043950f", "name": "p1rlv13681", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5fd72616-7318-4cb3-8643-7fa32865504e"}}}}, {"uuid": "55257008-f143-4a2f-b906-8ce95b1b534f", "name": "", "x": 38.58052339680616, "y": -122.51064825672786, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fdbfe616-f51f-416a-94ce-6e676d300226", "name": "p1rlv13717", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "55257008-f143-4a2f-b906-8ce95b1b534f"}}}}, {"uuid": "23176e93-7407-464d-bc9a-52c55cf5818d", "name": "", "x": 38.5805590114763, "y": -122.5105446871946, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0fe37b51-0258-4812-9d96-3cc28c4bd55b", "name": "p1rlv20509", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "23176e93-7407-464d-bc9a-52c55cf5818d"}}}}, {"uuid": "ec46f3c7-03e2-4c29-94a5-0dc5d4fb3c9f", "name": "", "x": 38.580430683168224, "y": -122.51091156777555, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "485928ba-ff70-4be2-89ff-721ff82269fb", "name": "p1rdm14063", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ec46f3c7-03e2-4c29-94a5-0dc5d4fb3c9f"}}}}, {"uuid": "e216cc59-9ec4-4e42-9d09-5a00f7118d8d", "name": "", "x": 38.580046353830355, "y": -122.51078926317813, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b2f95b8b-190c-4df2-9dd2-daee5efde34b", "name": "p1rlv13671", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e216cc59-9ec4-4e42-9d09-5a00f7118d8d"}}}}, {"uuid": "248a8ebb-00ae-4a38-8a4f-10d10e9c56ef", "name": "", "x": 38.5800731009349, "y": -122.51072019695825, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "17936036-1191-4f91-bc12-2298db7b77e3", "name": "p1rlv13714", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "248a8ebb-00ae-4a38-8a4f-10d10e9c56ef"}}}}, {"uuid": "5aa22a9c-1ce1-4621-93e7-b53b9e38c72c", "name": "", "x": 38.580347829371135, "y": -122.51152987084961, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ad6bef77-8f39-43b4-b2d7-58aa6e45a60b", "name": "p1rdt6514lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5aa22a9c-1ce1-4621-93e7-b53b9e38c72c"}}}}, {"uuid": "10a7ab33-dca2-44a2-bc4d-09ca6dbebcfa", "name": "", "x": 38.57949879960493, "y": -122.51130960918293, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "80f60ab3-722f-4765-8b91-4fd0196171d7", "name": "p1rlv13623", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10a7ab33-dca2-44a2-bc4d-09ca6dbebcfa"}}}}, {"uuid": "ab4f132b-fd01-4949-81d2-a31a140fcc7e", "name": "", "x": 38.57935703047459, "y": -122.51121121339025, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bb3b4207-12ad-46e6-b4de-59149a46f8a1", "name": "p1rlv13716", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ab4f132b-fd01-4949-81d2-a31a140fcc7e"}}}}, {"uuid": "eefb9220-0cb8-4f72-885d-44b3115ed714", "name": "", "x": 38.58034931676033, "y": -122.51127026442917, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "395dac73-8fae-4718-a28c-191a76a298f2", "name": "p1rdm14072", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eefb9220-0cb8-4f72-885d-44b3115ed714"}}}}, {"uuid": "f49e9feb-241d-4ae8-a52f-be30473ffb53", "name": "", "x": 38.57957036570457, "y": -122.51118283635456, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "653bdc0d-5b21-4640-861b-b88ddb5c651a", "name": "p1rlv13640", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f49e9feb-241d-4ae8-a52f-be30473ffb53"}}}}, {"uuid": "31dfa6e7-23d1-4264-b514-b8738ffa1920", "name": "", "x": 38.58109531398495, "y": -122.50927974477071, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b92f8bcd-91ce-42bd-be69-0b43cb9d4122", "name": "p1rdt6515lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "31dfa6e7-23d1-4264-b514-b8738ffa1920"}}}}, {"uuid": "67a2a8dc-35a0-49b1-85b2-43530b524e93", "name": "", "x": 38.580433778313484, "y": -122.50861675365525, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4c667408-52a0-4258-8e93-557c94520a1e", "name": "p1rlv13625", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "67a2a8dc-35a0-49b1-85b2-43530b524e93"}}}}, {"uuid": "d632ea7f-fd46-4991-a3bf-ed80f588f4d9", "name": "", "x": 38.58052341301346, "y": -122.50850133423494, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7538ab85-10b4-4f60-98f8-179e954173b0", "name": "p1rlv19156", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d632ea7f-fd46-4991-a3bf-ed80f588f4d9"}}}}, {"uuid": "06e2a999-5f7e-46c8-bf9b-88a07f0a6653", "name": "", "x": 38.58046037950707, "y": -122.50851324468255, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fed6fcd4-3c97-4f62-a1a7-0b66394218e1", "name": "p1rlv19163", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "06e2a999-5f7e-46c8-bf9b-88a07f0a6653"}}}}, {"uuid": "df7ea0fc-8400-41d7-97a9-b5124ecf0dbb", "name": "", "x": 38.580379081602544, "y": -122.50846787535407, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ebd10471-ab4c-4cb7-a822-a83ef20e9854", "name": "p1rlv19165", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "df7ea0fc-8400-41d7-97a9-b5124ecf0dbb"}}}}, {"uuid": "71c50c0a-c945-48cf-90f3-ca1f580683fc", "name": "", "x": 38.58118341315065, "y": -122.50918052803313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c2659bd3-f6ca-4d74-87c8-f92596986cb5", "name": "p1rdm14075", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "71c50c0a-c945-48cf-90f3-ca1f580683fc"}}}}, {"uuid": "2943ec98-4018-405c-ac02-33c2cd62a6ce", "name": "", "x": 38.58079429345362, "y": -122.50862577812117, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1acad56e-b6d6-4fa7-a925-f242c1558eef", "name": "p1rlv13645", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2943ec98-4018-405c-ac02-33c2cd62a6ce"}}}}, {"uuid": "a3f4101a-c9ca-45b8-ab85-d07e7ec45422", "name": "", "x": 38.57910373167705, "y": -122.51042872774359, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "119a8559-8e6c-4314-9bbd-37ef3adde415", "name": "p1rdt6516lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a3f4101a-c9ca-45b8-ab85-d07e7ec45422"}}}}, {"uuid": "8578e75a-d652-46c2-a395-6865bcbad53c", "name": "", "x": 38.579216271561, "y": -122.51055379999012, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b4358536-b06f-486d-b336-3a8576b428d0", "name": "p1rlv13629", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8578e75a-d652-46c2-a395-6865bcbad53c"}}}}, {"uuid": "8432571b-e34a-43d5-9e64-26876c6c1f96", "name": "", "x": 38.57907136448223, "y": -122.51038257383402, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "db3908f7-94f5-43a7-a3de-1f6c9b72ebd4", "name": "p1rlv13638", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8432571b-e34a-43d5-9e64-26876c6c1f96"}}}}, {"uuid": "fc5a608f-136d-45a3-b9d3-55b3b6c1f5d9", "name": "", "x": 38.57899879076654, "y": -122.51026826026441, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "091b545a-eb31-4bea-a0a6-5aa9c7a8397f", "name": "p1rlv13692", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fc5a608f-136d-45a3-b9d3-55b3b6c1f5d9"}}}}, {"uuid": "40f54f9d-097d-45d1-a5d8-f1a1f6a5fc6b", "name": "", "x": 38.579225763250356, "y": -122.51066854219654, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5a230534-6927-4af8-ba54-6ab4c9c32d21", "name": "p1rlv13708", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "40f54f9d-097d-45d1-a5d8-f1a1f6a5fc6b"}}}}, {"uuid": "7af31148-260a-4af0-929e-efbf262969e1", "name": "", "x": 38.578028811911885, "y": -122.51471027861992, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5783bae9-2c74-473f-bf18-db40bc975409", "name": "p1rdt6517lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7af31148-260a-4af0-929e-efbf262969e1"}}}}, {"uuid": "44e91cd6-7c3b-4399-82ed-b6d033f98399", "name": "", "x": 38.577889883003294, "y": -122.51448911519815, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f474e4ba-6300-4014-afe9-c245e08cf3c5", "name": "p1rlv13630", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "44e91cd6-7c3b-4399-82ed-b6d033f98399"}}}}, {"uuid": "7bdf2223-6574-4b58-aadb-d8e61843899a", "name": "", "x": 38.577945523946006, "y": -122.51486759582244, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "822f96e6-61c5-455d-8a53-a494b49c9237", "name": "p1rdm14084", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7bdf2223-6574-4b58-aadb-d8e61843899a"}}}}, {"uuid": "a906ae70-357e-4896-84e5-143cc3bd8545", "name": "", "x": 38.577881918670876, "y": -122.51474173870584, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4eb10938-4b73-406c-bed4-0bd01e0bc20d", "name": "p1rlv13641", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a906ae70-357e-4896-84e5-143cc3bd8545"}}}}, {"uuid": "143669c5-e2c1-4511-91b3-1ce3d7e385ed", "name": "", "x": 38.575528992640834, "y": -122.51891559878237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d9b16b03-1922-4aeb-8e70-d0e1387fbcab", "name": "p1rdt6518lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "143669c5-e2c1-4511-91b3-1ce3d7e385ed"}}}}, {"uuid": "9602fb20-3991-42c9-a5a7-a99c1dea8d9b", "name": "", "x": 38.5754218018766, "y": -122.51914367215898, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a8753d37-07f1-45c6-a483-43cbfb6bf107", "name": "p1rlv13647", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9602fb20-3991-42c9-a5a7-a99c1dea8d9b"}}}}, {"uuid": "5f715d2f-2c1a-4619-96c9-21d42566e2be", "name": "", "x": 38.57580840851501, "y": -122.51892297252556, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c597db56-a6af-472d-a7a2-e331175a2aae", "name": "p1rdm14085", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5f715d2f-2c1a-4619-96c9-21d42566e2be"}}}}, {"uuid": "bba05f6a-3c85-4a4a-81a0-c367140f6a1f", "name": "", "x": 38.57579807527307, "y": -122.51860159809428, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7b712121-d0c2-488a-9224-bea72928796f", "name": "p1rlv13632", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bba05f6a-3c85-4a4a-81a0-c367140f6a1f"}}}}, {"uuid": "df87e52c-507b-4c49-89b5-d67af8264dd1", "name": "", "x": 38.57533041118428, "y": -122.51883432018805, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "180c5680-acd1-4988-ac36-1f351c3f9418", "name": "p1rdm14087", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "df87e52c-507b-4c49-89b5-d67af8264dd1"}}}}, {"uuid": "4395a690-5c9a-46b3-adb7-ac922592d62f", "name": "", "x": 38.57533575960138, "y": -122.51944669646048, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "02f2e50e-d42d-47d1-9274-d840042b64d1", "name": "p1rlv20154", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4395a690-5c9a-46b3-adb7-ac922592d62f"}}}}, {"uuid": "11000b69-6f7e-48dc-859f-2cdd46f95489", "name": "", "x": 38.575287380857716, "y": -122.5193282488865, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "11a125b8-023c-4748-98a9-d74e9e0a7d23", "name": "p1rlv20161", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "11000b69-6f7e-48dc-859f-2cdd46f95489"}}}}, {"uuid": "ee4d4eec-5dfb-4f0b-b0f6-1164bf7d8847", "name": "", "x": 38.58088300114921, "y": -122.50941317390307, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "606673ea-bcd2-459a-a0af-efb8b31c600c", "name": "p1rdt6519lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ee4d4eec-5dfb-4f0b-b0f6-1164bf7d8847"}}}}, {"uuid": "d8ed7224-a9d9-4391-b993-936a9f14dbc6", "name": "", "x": 38.58045459525182, "y": -122.5092825015312, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d4d3fe62-b327-4fc6-b2aa-795c9475019a", "name": "p1rlv13636", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d8ed7224-a9d9-4391-b993-936a9f14dbc6"}}}}, {"uuid": "cc47d065-a18b-4a0d-bbb1-a923026636c1", "name": "", "x": 38.5808931056819, "y": -122.50952733350167, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3e06b069-62f8-40c8-9abc-d4cc83937e41", "name": "p1rdm14090", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc47d065-a18b-4a0d-bbb1-a923026636c1"}}}}, {"uuid": "8316b40c-759e-4de9-82e2-b7599bcc368e", "name": "", "x": 38.58036317851489, "y": -122.5089731408155, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32b75c61-4e97-4e21-a786-8aab7a2d88f8", "name": "p1rlv13678", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8316b40c-759e-4de9-82e2-b7599bcc368e"}}}}, {"uuid": "2b9af43c-355e-4977-af5d-fe2deaa37cb9", "name": "", "x": 38.580046706763056, "y": -122.51235461842337, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "13c02cd3-cff3-4988-95b9-3993b9541427", "name": "p1rdt6520lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2b9af43c-355e-4977-af5d-fe2deaa37cb9"}}}}, {"uuid": "07a6bf40-9c43-494c-a5e0-aedfb16e2e8b", "name": "", "x": 38.580041773656525, "y": -122.51253040494485, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5484eab0-53a8-471c-92ec-29c11c08e740", "name": "p1rlv13639", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "07a6bf40-9c43-494c-a5e0-aedfb16e2e8b"}}}}, {"uuid": "d1a1887e-68b9-4ba7-bb1e-9559ec608ccd", "name": "", "x": 38.5799894527048, "y": -122.51227067031124, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "607d3b54-2cea-476b-afe2-ea40c6c02ddc", "name": "p1rlv13669", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1a1887e-68b9-4ba7-bb1e-9559ec608ccd"}}}}, {"uuid": "0a2e9171-72f9-4d27-851c-45eabbd30ece", "name": "", "x": 38.57993605226405, "y": -122.51243176231385, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "db3abe20-2ffb-4bf8-b425-5613701bd3f2", "name": "p1rdm14092", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a2e9171-72f9-4d27-851c-45eabbd30ece"}}}}, {"uuid": "3e3df82e-7e0f-40fc-aef7-434dfc7f6cd8", "name": "", "x": 38.579872492217575, "y": -122.51231738436074, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2e55b944-ffad-47bf-8348-799afa4c7a1d", "name": "p1rlv13662", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e3df82e-7e0f-40fc-aef7-434dfc7f6cd8"}}}}, {"uuid": "7ede4855-ada0-4ba8-b0c6-2cef3422a414", "name": "", "x": 38.57984627020021, "y": -122.51251273462697, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c0c27b40-83a9-4938-bc12-a2ae57d5eafb", "name": "p1rdm14096", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7ede4855-ada0-4ba8-b0c6-2cef3422a414"}}}}, {"uuid": "88e1daf5-aee2-4047-8cda-6569b0fbeae0", "name": "", "x": 38.57983668465647, "y": -122.51237503029868, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "284bbc5d-bb49-404d-823e-08ec543c90b8", "name": "p1rlv13679", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "88e1daf5-aee2-4047-8cda-6569b0fbeae0"}}}}, {"uuid": "a229c490-a965-4a8a-b3d8-c55d37bf829d", "name": "", "x": 38.57981055069724, "y": -122.51248335572157, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eb3a7829-4233-4af9-9679-08bd114bc00e", "name": "p1rdm14097", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a229c490-a965-4a8a-b3d8-c55d37bf829d"}}}}, {"uuid": "9ccf5d63-0b54-4e31-90f0-2d4a9ce2a633", "name": "", "x": 38.57972969205857, "y": -122.51265129155006, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4f409299-5ac0-4f31-a217-d0aef7fbc4d2", "name": "p1rlv13705", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9ccf5d63-0b54-4e31-90f0-2d4a9ce2a633"}}}}, {"uuid": "8f222518-4a99-4211-9e54-fd4adc5c5032", "name": "", "x": 38.58009749717621, "y": -122.51224697801528, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8a990c6c-4227-4896-8ea6-e92ce5360087", "name": "p1rdm14094", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8f222518-4a99-4211-9e54-fd4adc5c5032"}}}}, {"uuid": "fa7fa1c1-aa2d-4cac-bf81-c50e1d993e77", "name": "", "x": 38.580215414329274, "y": -122.51242987363875, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9467d2d3-ad80-4bc7-aa9f-cd6e76494552", "name": "p1rlv13673", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa7fa1c1-aa2d-4cac-bf81-c50e1d993e77"}}}}, {"uuid": "9bc63553-29f4-4a9a-b99b-5521c3a3c329", "name": "", "x": 38.58029613681535, "y": -122.51233748122965, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c532e298-bdd5-416e-8ebe-a082489ffee6", "name": "p1rlv13675", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9bc63553-29f4-4a9a-b99b-5521c3a3c329"}}}}, {"uuid": "d688086c-831c-45c9-9d48-2f297d145d3d", "name": "", "x": 38.5803966658545, "y": -122.51095681258643, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d0e4e42c-8dcd-47be-bfe8-b8b1eb4a5f24", "name": "p1rdt6521lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d688086c-831c-45c9-9d48-2f297d145d3d"}}}}, {"uuid": "c69b4e5a-4201-42e7-810c-2cf0ebcc7981", "name": "", "x": 38.579486477877886, "y": -122.51051752411439, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ce53d307-fc73-487a-8f6a-3a0e0787bf79", "name": "p1rlv13670", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c69b4e5a-4201-42e7-810c-2cf0ebcc7981"}}}}, {"uuid": "690138af-24c1-49be-867e-6680bd0377bf", "name": "", "x": 38.57976641593619, "y": -122.51065339312383, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1de2ebf2-3207-4bf7-9702-4c729d99a6cf", "name": "p1rlv13694", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "690138af-24c1-49be-867e-6680bd0377bf"}}}}, {"uuid": "1a45c60d-d023-4cae-a611-68068c4a0593", "name": "", "x": 38.579567775011846, "y": -122.51056289521121, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d73963d7-acf4-48b3-8e54-6ee9f403d36f", "name": "p1rlv13695", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1a45c60d-d023-4cae-a611-68068c4a0593"}}}}, {"uuid": "caab1a9d-2a8c-4eed-959a-9039332e3168", "name": "", "x": 38.58050191288654, "y": -122.51070442912985, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c12be3d4-719e-4567-91d9-c0ff24b783f1", "name": "p1rdm14098", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "caab1a9d-2a8c-4eed-959a-9039332e3168"}}}}, {"uuid": "754ba22d-779c-4aa4-b7ce-548fb7f221dc", "name": "", "x": 38.579756732183114, "y": -122.51049272837687, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "479d1486-ed05-44fa-8fab-64035623f267", "name": "p1rlv13642", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "754ba22d-779c-4aa4-b7ce-548fb7f221dc"}}}}, {"uuid": "4d31dd12-f830-474c-9bda-1130c7c4b4f8", "name": "", "x": 38.58037890435985, "y": -122.51109366072052, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1db9a47a-f0ed-4141-b08e-f01a2ffd804f", "name": "p1rdm14100", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d31dd12-f830-474c-9bda-1130c7c4b4f8"}}}}, {"uuid": "8a46299e-61ca-4b07-a11b-4ca253e6e6cf", "name": "", "x": 38.57950522126574, "y": -122.51068960750169, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9a3c050c-cc0d-460e-af02-ce3421431474", "name": "p1rlv13682", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8a46299e-61ca-4b07-a11b-4ca253e6e6cf"}}}}, {"uuid": "c77f9530-ec0a-4054-9a05-006d849ef1ad", "name": "", "x": 38.57973678683187, "y": -122.51254142741766, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "66df2481-ae4f-4f39-aef4-7af09ce1a8fb", "name": "p1rdt6523lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c77f9530-ec0a-4054-9a05-006d849ef1ad"}}}}, {"uuid": "f39c6dd4-71cf-4d64-bcb4-da1faefa9fbc", "name": "", "x": 38.5799209440274, "y": -122.51313219164904, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "43867e2f-79ee-4cec-bed3-0cad0727118c", "name": "p1rlv13649", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f39c6dd4-71cf-4d64-bcb4-da1faefa9fbc"}}}}, {"uuid": "38154626-549f-4873-8768-aab4b840920b", "name": "", "x": 38.58054870314674, "y": -122.51023477359377, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2844042b-3f65-4a8b-8bab-56b42971e6ad", "name": "p1rdm14107", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "38154626-549f-4873-8768-aab4b840920b"}}}}, {"uuid": "28d5033a-494a-4830-857c-27385f72f97e", "name": "", "x": 38.58037752934179, "y": -122.51024741691637, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e8c0a04e-6e22-4da5-9907-7ae8097deb10", "name": "p1rlv13656", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "28d5033a-494a-4830-857c-27385f72f97e"}}}}, {"uuid": "6a791e00-55dc-4756-be50-d51a7faea780", "name": "", "x": 38.58064802372938, "y": -122.51028002263617, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "71c26ca3-0d61-46b8-a95b-710e0b760b62", "name": "p1rlv13690", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a791e00-55dc-4756-be50-d51a7faea780"}}}}, {"uuid": "1307498e-2f33-4f26-9a24-ed1f4799a1a1", "name": "", "x": 38.580549321580946, "y": -122.51038626364308, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0ec2137a-f978-4808-a023-21f13464998b", "name": "p1rdt6524lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1307498e-2f33-4f26-9a24-ed1f4799a1a1"}}}}, {"uuid": "97e975d1-b903-4ebf-b362-88304a9e927a", "name": "", "x": 38.58052253264507, "y": -122.51044160695697, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2256f06d-59e9-4822-987f-7d26f40415c0", "name": "p1rdm14109", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "97e975d1-b903-4ebf-b362-88304a9e927a"}}}}, {"uuid": "980817ce-f98e-4842-9e4e-62861e103709", "name": "", "x": 38.58056754300597, "y": -122.51042982053421, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ecf9ee9-2a3c-431b-84c8-02c7c7aaacb1", "name": "p1rlv13700", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "980817ce-f98e-4842-9e4e-62861e103709"}}}}, {"uuid": "6b9561d7-37ff-4c73-939a-cae0bfc6f012", "name": "", "x": 38.579048350921525, "y": -122.51041447766671, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f8905812-7e3b-4875-87b5-da95999c5bb0", "name": "p1rdt6527lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6b9561d7-37ff-4c73-939a-cae0bfc6f012"}}}}, {"uuid": "171206bc-5e24-403f-8776-7735ef98c781", "name": "", "x": 38.57906268295511, "y": -122.51046524008142, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ef8e6ec-86d3-429c-89b4-6c7260701e70", "name": "p1rlv13661", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "171206bc-5e24-403f-8776-7735ef98c781"}}}}, {"uuid": "29a9d0b7-9834-4fb6-9592-8530158d8ade", "name": "", "x": 38.581032746102906, "y": -122.50929836357719, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d097d9be-dd3a-4616-a873-8ab5013c4e72", "name": "p1rdt6528lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "29a9d0b7-9834-4fb6-9592-8530158d8ade"}}}}, {"uuid": "b43a9112-3dd0-4606-b9e2-b2c280cccd50", "name": "", "x": 38.580921613298514, "y": -122.50890045296518, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d6cdd514-204d-4a86-b0f3-a9bc4990a2aa", "name": "p1rlv13667", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b43a9112-3dd0-4606-b9e2-b2c280cccd50"}}}}, {"uuid": "7b51efa8-65e3-4715-b4c4-3e3fc9865126", "name": "", "x": 38.58083655075754, "y": -122.508633001311, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "850df31b-ee95-4903-93b7-6e5911e8f8a0", "name": "p1rlv13691", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7b51efa8-65e3-4715-b4c4-3e3fc9865126"}}}}, {"uuid": "7124613f-6902-4611-8bf2-0685d7cdd0ca", "name": "", "x": 38.581173273294354, "y": -122.50945964206286, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b51fe8ae-f6d7-48c7-9f84-22fc7c1c1ba9", "name": "p1rdm14115", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7124613f-6902-4611-8bf2-0685d7cdd0ca"}}}}, {"uuid": "f6ed6571-05e2-410b-a5cb-bc043ce84079", "name": "", "x": 38.58081366588884, "y": -122.50894711172428, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6e5db11f-0418-4119-9c71-26619456fd7b", "name": "p1rlv13689", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f6ed6571-05e2-410b-a5cb-bc043ce84079"}}}}, {"uuid": "f1617a39-6b0b-473b-925f-e682bab9adfc", "name": "", "x": 38.57747782265656, "y": -122.51577372256881, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e4ee2d3a-e97c-4ec4-9fa0-d7db1b3e9253", "name": "p1rdt6530lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f1617a39-6b0b-473b-925f-e682bab9adfc"}}}}, {"uuid": "3e778788-41ab-4bac-aa92-c2f1a99a4d9e", "name": "", "x": 38.57719931368139, "y": -122.51529738764073, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ec49353-14d1-4917-83bc-ca62cd94bf30", "name": "p1rlv13684", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e778788-41ab-4bac-aa92-c2f1a99a4d9e"}}}}, {"uuid": "b3fcdf02-4c33-493d-9575-5ea120899df5", "name": "", "x": 38.578752758421444, "y": -122.51042399893916, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bf4a2da0-682a-4119-b398-feaa6f5a8498", "name": "p1rdt6531lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b3fcdf02-4c33-493d-9575-5ea120899df5"}}}}, {"uuid": "dc1038de-320a-4318-bcb0-e653ac19b58f", "name": "", "x": 38.57871154896236, "y": -122.51041164293123, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c5815b75-1226-4221-9bcb-bc75ce85fa17", "name": "p1rlv13693", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dc1038de-320a-4318-bcb0-e653ac19b58f"}}}}, {"uuid": "95a9d089-ce98-467f-8ea9-9b42f507f74f", "name": "", "x": 38.58148963770846, "y": -122.5089654708908, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75c95c35-ea3f-4958-9512-606f78de92b5", "name": "p1rdm14120", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "95a9d089-ce98-467f-8ea9-9b42f507f74f"}}}}, {"uuid": "d03f9226-6e80-4991-b4fc-56e75e294b1f", "name": "", "x": 38.581272297668534, "y": -122.50871436904568, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e60fc98a-9c1d-4975-a9b9-e37271b4ac81", "name": "p1rlv13706", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d03f9226-6e80-4991-b4fc-56e75e294b1f"}}}}, {"uuid": "3c14900e-d03a-4b45-805a-10573b24aa91", "name": "", "x": 38.58157778587544, "y": -122.50884357066717, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c0c3e71a-52a1-49b9-a899-c13d639ac0a6", "name": "p1rdt6532lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3c14900e-d03a-4b45-805a-10573b24aa91"}}}}, {"uuid": "9540f591-cdc2-440a-94fd-1e5f0e14566d", "name": "", "x": 38.581615271240324, "y": -122.50883832397932, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7194199d-e430-4b76-ae77-4c7f51477eed", "name": "p1rdm14121", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9540f591-cdc2-440a-94fd-1e5f0e14566d"}}}}, {"uuid": "fcad0d46-75ae-46e8-b3c1-38c221ef9313", "name": "", "x": 38.5814179357273, "y": -122.50838439741678, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6e396aca-4116-40a0-8f17-bcd41f709ea5", "name": "p1rlv19151", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fcad0d46-75ae-46e8-b3c1-38c221ef9313"}}}}, {"uuid": "e22ae8fc-869d-4fcc-a72c-f32024a9b73d", "name": "", "x": 38.58107483274763, "y": -122.50959807912284, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "10f0e9fa-75b8-4eaa-a2ad-b6a3fb4ae859", "name": "p1rdt6535lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e22ae8fc-869d-4fcc-a72c-f32024a9b73d"}}}}, {"uuid": "0bddd491-bc72-4bbc-94d6-54da98b4518e", "name": "", "x": 38.58061410818166, "y": -122.50863848671041, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d2bfaa34-267c-4dfd-8b6d-4ab444ac4048", "name": "p1rlv13711", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0bddd491-bc72-4bbc-94d6-54da98b4518e"}}}}, {"uuid": "88973f79-5169-4a1b-921d-7cd7c4ba37ab", "name": "", "x": 38.58093200049442, "y": -122.50908714544045, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b93e7299-60a4-49d6-9d34-885860588861", "name": "p1rdt6536lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "88973f79-5169-4a1b-921d-7cd7c4ba37ab"}}}}, {"uuid": "cd358d57-6ede-4102-b78b-91c55b2a32d8", "name": "", "x": 38.58096835695191, "y": -122.50930196751384, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ee766a99-bb6f-4d5c-8513-9d462103f6fc", "name": "p1rlv13713", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cd358d57-6ede-4102-b78b-91c55b2a32d8"}}}}, {"uuid": "3c0b623a-bb42-42e7-96ad-2d9e0d3d3aed", "name": "", "x": 38.58099515130269, "y": -122.50924438048082, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a0f1846b-2515-48ef-9241-0276932f8e75", "name": "p1rlv13723", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3c0b623a-bb42-42e7-96ad-2d9e0d3d3aed"}}}}, {"uuid": "19e3403c-a263-4796-b98b-3831b386ca8d", "name": "", "x": 38.58098269315429, "y": -122.5094004338482, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "57ac4a24-2ddb-46c2-873d-c0b4f3e0600a", "name": "p1rdm14127", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "19e3403c-a263-4796-b98b-3831b386ca8d"}}}}, {"uuid": "d78ff223-7105-40b8-bf1b-61b854c6f63a", "name": "", "x": 38.581152353955275, "y": -122.50952282376217, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cd0effe0-d186-41a8-8197-24144fbc6218", "name": "p1rlv20478", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d78ff223-7105-40b8-bf1b-61b854c6f63a"}}}}, {"uuid": "14987673-7f92-410c-ab47-2773ed46e137", "name": "", "x": 38.575043333110195, "y": -122.51764982578192, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b34f50ff-9a1f-439e-81a8-dfcee658926b", "name": "p1rdt6539lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "14987673-7f92-410c-ab47-2773ed46e137"}}}}, {"uuid": "1276727e-e436-4f80-afa1-9972acfe3f6f", "name": "", "x": 38.57528171570155, "y": -122.51795068214895, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "36019623-eb62-412c-a591-41494980c9b7", "name": "p1rlv13727", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1276727e-e436-4f80-afa1-9972acfe3f6f"}}}}, {"uuid": "016059b9-2ab8-4187-9495-83fc87cb1e18", "name": "", "x": 38.57506491492146, "y": -122.51782585098714, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "006c2753-37b3-4b59-82a6-8ce95f316e26", "name": "p1rlv20450", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "016059b9-2ab8-4187-9495-83fc87cb1e18"}}}}, {"uuid": "51262455-014d-42fc-a2c6-b55e1fecf6c2", "name": "", "x": 38.660324342235185, "y": -122.44998273762167, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "36ab64e0-65cb-4515-9c06-4762a398672a", "name": "p1rdm14185", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "51262455-014d-42fc-a2c6-b55e1fecf6c2"}}}}, {"uuid": "b6bdd6fb-bd85-419a-818b-875257aff1db", "name": "", "x": 38.6601489758078, "y": -122.44970425964786, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "01a18948-75cf-4caf-951f-17a9c8d1f6bc", "name": "p1rlv13784", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b6bdd6fb-bd85-419a-818b-875257aff1db"}}}}, {"uuid": "9f0f8df4-1f7f-44b5-9ff9-a1e84cc3bf9c", "name": "", "x": 38.660528052085354, "y": -122.4498277884296, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4a43920a-a200-40fe-b5b6-3cdba0c7e784", "name": "p1rdt6574lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9f0f8df4-1f7f-44b5-9ff9-a1e84cc3bf9c"}}}}, {"uuid": "1af54902-4345-44cc-8578-75cb2bb7fef3", "name": "", "x": 38.66069273125682, "y": -122.44975004725573, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7f2b4d47-9668-4bcc-933b-1f422f423e3e", "name": "p1rdm14186", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1af54902-4345-44cc-8578-75cb2bb7fef3"}}}}, {"uuid": "c7901057-6ff0-4903-aead-e90a06af9e66", "name": "", "x": 38.66068307092049, "y": -122.44961219759635, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ffd737b-a273-4a6c-91c6-351b5719f658", "name": "p1rlv13812", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c7901057-6ff0-4903-aead-e90a06af9e66"}}}}, {"uuid": "8b51ed47-dfcb-4c2e-ac55-4c15c9ca7323", "name": "", "x": 38.659329203857624, "y": -122.45168740029418, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "608e485b-13ce-493b-be96-ab83ad733c92", "name": "p1rdt6581lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8b51ed47-dfcb-4c2e-ac55-4c15c9ca7323"}}}}, {"uuid": "f950a428-2ee0-42b5-bca3-f9b32c5e4d26", "name": "", "x": 38.66001044613518, "y": -122.45222637580909, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "65052833-aec9-4363-a0cf-4d70fa9bb0ce", "name": "p1rlv13797", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f950a428-2ee0-42b5-bca3-f9b32c5e4d26"}}}}, {"uuid": "44852aa5-fa2c-4502-9c7e-66f3665c8c8e", "name": "", "x": 38.65980253637742, "y": -122.45209003761849, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0aef2ef8-706c-4316-be01-0707ddf0ac7c", "name": "p1rlv13811", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "44852aa5-fa2c-4502-9c7e-66f3665c8c8e"}}}}, {"uuid": "405d3e33-0803-4bab-bab6-03ae336215f7", "name": "", "x": 38.659439276645934, "y": -122.45149514678252, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b8b7c677-d0bf-47d0-8a2a-78417faa49b9", "name": "p1rdm14205", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "405d3e33-0803-4bab-bab6-03ae336215f7"}}}}, {"uuid": "d0122f2a-41cc-4246-90f8-a04abd00afa7", "name": "", "x": 38.660111562159514, "y": -122.45204568307697, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dc5fcb56-435a-4a0d-b442-7489a98ad1cd", "name": "p1rlv13792", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d0122f2a-41cc-4246-90f8-a04abd00afa7"}}}}, {"uuid": "7d3f6c6b-b89e-4239-8ced-0de9f6cea967", "name": "", "x": 38.65993673921714, "y": -122.45188213185789, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c9725b6c-5bac-456a-bb6a-ce16a5e6b1a5", "name": "p1rlv13794", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7d3f6c6b-b89e-4239-8ced-0de9f6cea967"}}}}, {"uuid": "5807dfff-f120-476d-b028-21c8ea93379e", "name": "", "x": 38.66019931022639, "y": -122.45214448227058, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "83d60921-a1f2-4b9c-9709-d2be59b82db5", "name": "p1rlv13805", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5807dfff-f120-476d-b028-21c8ea93379e"}}}}, {"uuid": "762a9906-8f58-46f4-8c29-6a02b47cc88d", "name": "", "x": 38.65918069105062, "y": -122.45208328210967, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "487eef02-df2d-47fe-a20b-ce1c23064495", "name": "p1rdm14210", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "762a9906-8f58-46f4-8c29-6a02b47cc88d"}}}}, {"uuid": "883511c6-7a7d-486b-8068-fcb271ee85b0", "name": "", "x": 38.65967739844402, "y": -122.45230936703297, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "604cb559-0f18-4ef7-8bcd-a07a7e7f96d7", "name": "p1rlv19691", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "883511c6-7a7d-486b-8068-fcb271ee85b0"}}}}, {"uuid": "93ef6245-d527-43bb-bc70-7d08a2b64e0e", "name": "", "x": 38.6320710830909, "y": -122.46441945032754, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e7b9897e-b820-424c-adf8-7416de585357", "name": "p1rdt6847lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "93ef6245-d527-43bb-bc70-7d08a2b64e0e"}}}}, {"uuid": "7ee9b2d7-249f-4fa4-85bc-5e321dccdcdf", "name": "", "x": 38.632085435147204, "y": -122.46447024061165, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "06135bd7-6a77-4f04-a439-4ce8c245447d", "name": "p1rlv14434", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7ee9b2d7-249f-4fa4-85bc-5e321dccdcdf"}}}}, {"uuid": "d54e3cca-aebe-44b5-9000-f52ec82f8845", "name": "", "x": 38.62923340048788, "y": -122.45439823840434, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "94c9fa37-fc5c-4243-b0ca-f70840febaee", "name": "p1rdt6848lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d54e3cca-aebe-44b5-9000-f52ec82f8845"}}}}, {"uuid": "ead318c5-17a0-4d28-9e0b-0029efe1f9ba", "name": "", "x": 38.62920980622029, "y": -122.45452876435519, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d07f5065-df41-484d-8e8a-80b2ff4e0e9b", "name": "p1rlv14435", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ead318c5-17a0-4d28-9e0b-0029efe1f9ba"}}}}, {"uuid": "ef518207-8f21-4771-84fd-ac07da8214a1", "name": "", "x": 38.62930775436262, "y": -122.45427527251405, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ad66e41a-88ab-443e-b10e-9e7b5b899119", "name": "p1rlv14436", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef518207-8f21-4771-84fd-ac07da8214a1"}}}}, {"uuid": "1ee5b07a-7cbd-4569-b1aa-52fb1b80f325", "name": "", "x": 38.648478696952125, "y": -122.39365801344734, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "09a476ff-48a0-4d27-9cf0-c007e2e98acb", "name": "p1rdt6995lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1ee5b07a-7cbd-4569-b1aa-52fb1b80f325"}}}}, {"uuid": "c4dd9eca-e51f-46cd-9b27-abc8d242acdf", "name": "", "x": 38.6484526903026, "y": -122.39361541442939, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c9efa4c9-9832-4aa8-bf44-be0fe1e80cd5", "name": "p1rlv14828", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c4dd9eca-e51f-46cd-9b27-abc8d242acdf"}}}}, {"uuid": "a6befc82-8adc-4a0d-a14e-865e43d77c0a", "name": "", "x": 38.64916844328969, "y": -122.39459452477139, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "536d7c56-85a6-4167-b4f6-2f39936cd662", "name": "p1rdt7015lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a6befc82-8adc-4a0d-a14e-865e43d77c0a"}}}}, {"uuid": "d69748df-ccc3-48ce-9654-18f617d9fb69", "name": "", "x": 38.64918282560407, "y": -122.39464531276182, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d73b0321-e181-4ecd-b431-9aa6985d56d0", "name": "p1rlv14908", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d69748df-ccc3-48ce-9654-18f617d9fb69"}}}}, {"uuid": "8fcb6705-048d-4877-a0bc-e606511d2295", "name": "", "x": 38.56296537249011, "y": -122.50762584426352, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1a371c8b-1993-432c-b2c6-21b18bec27da", "name": "p1rdt7036lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8fcb6705-048d-4877-a0bc-e606511d2295"}}}}, {"uuid": "9037b898-87b5-4754-92ad-23b3c26383e7", "name": "", "x": 38.56302965746093, "y": -122.50745371127641, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3c39b0c-9c92-4934-876f-ee5f542f95cc", "name": "p1rlv14952", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9037b898-87b5-4754-92ad-23b3c26383e7"}}}}, {"uuid": "125c32e8-53ea-4b99-a462-4873a5fbd551", "name": "", "x": 38.562911104383154, "y": -122.50779489358709, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "260ea1f0-7235-47fc-a576-3d647618290e", "name": "p1rdm15468", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "125c32e8-53ea-4b99-a462-4873a5fbd551"}}}}, {"uuid": "dfd993e3-9f3d-4b0c-bd6a-abd0bcfed918", "name": "", "x": 38.56269409956021, "y": -122.50762420325977, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "19231152-1fd1-4e07-a5d9-603c765b2cae", "name": "p1rlv15008", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dfd993e3-9f3d-4b0c-bd6a-abd0bcfed918"}}}}, {"uuid": "adac6dc8-8be6-48fb-949a-6b94d12f7d4b", "name": "", "x": 38.56256229551184, "y": -122.50269706817427, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "046f6c53-8d9c-43a1-88ce-169ade9e9557", "name": "p1rdt7038lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "adac6dc8-8be6-48fb-949a-6b94d12f7d4b"}}}}, {"uuid": "8ca7ccc6-e0d8-4b03-856f-60ac9d14b366", "name": "", "x": 38.562607012632625, "y": -122.50261641391278, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a9e128f5-eb18-44df-8ec4-35bd049ef630", "name": "p1rlv14954", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8ca7ccc6-e0d8-4b03-856f-60ac9d14b366"}}}}, {"uuid": "e911b985-e79e-4f2c-93b3-ef325ec3ea1e", "name": "", "x": 38.56228530015727, "y": -122.50538482056976, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cd6a9808-9889-4f16-825d-c9763357c293", "name": "p1rdt7046lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e911b985-e79e-4f2c-93b3-ef325ec3ea1e"}}}}, {"uuid": "859e95c6-17e7-4a0d-9a9d-6892808b6de9", "name": "", "x": 38.56236063103573, "y": -122.50548009684834, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "884ff47e-8e20-4ae8-97bd-287d0ca9dc1b", "name": "p1rlv14974", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "859e95c6-17e7-4a0d-9a9d-6892808b6de9"}}}}, {"uuid": "971c2a17-55d8-4d9f-9371-a6f61aafe5a7", "name": "", "x": 38.558417547967906, "y": -122.507932804306, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf93e681-3ab6-4929-95f1-1da6d5dd28fa", "name": "p1rdt7054lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "971c2a17-55d8-4d9f-9371-a6f61aafe5a7"}}}}, {"uuid": "08d23886-0c5d-44c8-b2ad-7ea381317beb", "name": "", "x": 38.55834318385272, "y": -122.50806707079614, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f4f8b1bc-83c3-4819-9d98-9491df98d494", "name": "p1rlv14992", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "08d23886-0c5d-44c8-b2ad-7ea381317beb"}}}}, {"uuid": "2b6a7bde-a0c4-449f-8fe4-d8400882bf90", "name": "", "x": 38.55812685464717, "y": -122.50805706795369, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a914ec3a-4883-42a7-b25d-133a1410b8d9", "name": "p1rlv15056", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2b6a7bde-a0c4-449f-8fe4-d8400882bf90"}}}}, {"uuid": "5e15ee0b-3693-41ac-8cb0-055c517b69d7", "name": "", "x": 38.558469106593094, "y": -122.50800882572935, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25a6c92d-ea7f-4ede-af16-713ceedfc7b0", "name": "p1rdm15533", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5e15ee0b-3693-41ac-8cb0-055c517b69d7"}}}}, {"uuid": "356f834c-0b74-448a-bb21-123afc00d12d", "name": "", "x": 38.558289451182375, "y": -122.50814777833953, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2182c9fd-fd3d-4cb1-b525-192480823e2f", "name": "p1rlv15046", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "356f834c-0b74-448a-bb21-123afc00d12d"}}}}, {"uuid": "1aaf2a4d-ff03-454e-a713-9582309fa5ce", "name": "", "x": 38.559657411750145, "y": -122.50277093263843, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bc33ade7-4471-40b8-8e9b-1846e0ad60e8", "name": "p1rdt7061lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1aaf2a4d-ff03-454e-a713-9582309fa5ce"}}}}, {"uuid": "637627d3-e56a-4bc8-9ff8-1a6c5760087b", "name": "", "x": 38.55937583329394, "y": -122.50291811146595, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cc29de5b-3a3f-40c0-bde4-9a57f5f62b5c", "name": "p1rlv15007", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "637627d3-e56a-4bc8-9ff8-1a6c5760087b"}}}}, {"uuid": "2c405f7c-6e09-4705-a315-e45355677bb1", "name": "", "x": 38.563364746370645, "y": -122.50424505524006, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f4445ca5-2fed-4352-ab78-66e072a4f482", "name": "p1rdm15583", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2c405f7c-6e09-4705-a315-e45355677bb1"}}}}, {"uuid": "55ebc70c-c0d4-4a17-bcc7-8a77aee0e74b", "name": "", "x": 38.56324735128747, "y": -122.50418847116366, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "07e3b847-cc9a-4f84-bc00-cb4396b6dea0", "name": "p1rlv15027", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "55ebc70c-c0d4-4a17-bcc7-8a77aee0e74b"}}}}, {"uuid": "c5817b8f-ea88-454f-88ee-92b03f9a1ddf", "name": "", "x": 38.56307400876931, "y": -122.50435786467884, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1ff878e1-3143-4f8e-aa92-74d0a9046417", "name": "p1rdt7067lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c5817b8f-ea88-454f-88ee-92b03f9a1ddf"}}}}, {"uuid": "a34ca3d2-08f9-4046-8516-8323c5dbc0bb", "name": "", "x": 38.562913772741126, "y": -122.50415632890832, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5ad4c131-0be7-46e5-8a32-5ff92552dfe6", "name": "p1rdm15584", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a34ca3d2-08f9-4046-8516-8323c5dbc0bb"}}}}, {"uuid": "e8c80a4b-9086-4dc3-828c-6661b91adb34", "name": "", "x": 38.563057133200985, "y": -122.50396021637685, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "80a74c6f-c9ec-4742-8fce-ad73c0a6c459", "name": "p1rlv15197", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e8c80a4b-9086-4dc3-828c-6661b91adb34"}}}}, {"uuid": "63c74f01-b8e6-49bc-8ad2-88e28191cae0", "name": "", "x": 38.559099227598956, "y": -122.50637076262426, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9a1566f1-7f0d-41d7-adad-425c9a344eb0", "name": "p1rdt7069lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "63c74f01-b8e6-49bc-8ad2-88e28191cae0"}}}}, {"uuid": "12d42c56-9b80-4486-a359-8e37f81f809d", "name": "", "x": 38.558729158203484, "y": -122.50556236696406, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "baccbdab-efc0-487d-b00d-38d3d4be57b4", "name": "p1rlv15045", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "12d42c56-9b80-4486-a359-8e37f81f809d"}}}}, {"uuid": "56999ec8-df70-47e8-a22e-684768da3d2c", "name": "", "x": 38.56237327512186, "y": -122.49906112727943, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "844bdc22-2e32-43ee-8e0b-26f3f4c107b8", "name": "p1rdt7070lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "56999ec8-df70-47e8-a22e-684768da3d2c"}}}}, {"uuid": "e3bc0fa3-6811-498e-a16c-8320d0a293f7", "name": "", "x": 38.5623473065519, "y": -122.49901854030558, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "366c9c98-59f1-46d5-b39c-4046703e5e4b", "name": "p1rlv15064", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e3bc0fa3-6811-498e-a16c-8320d0a293f7"}}}}, {"uuid": "a83cc9c4-4b11-4010-aa19-b53e73508459", "name": "", "x": 38.56125382119533, "y": -122.50733957591181, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0e0577c2-8275-4303-ad11-2c4f56df3f5c", "name": "p1rdt7075lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a83cc9c4-4b11-4010-aa19-b53e73508459"}}}}, {"uuid": "9a93678c-2745-43ef-87e0-0b312f04dcc6", "name": "", "x": 38.56131680649824, "y": -122.50731619031008, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a56b9ad8-c53b-4652-bf94-a7a7dfb8b306", "name": "p1rlv15082", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9a93678c-2745-43ef-87e0-0b312f04dcc6"}}}}, {"uuid": "5c7c788f-e292-4ed5-b8b6-2d92179a1549", "name": "", "x": 38.561391603460336, "y": -122.50795843776592, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d86bd7f-7759-4d74-9c74-d58010498f92", "name": "p1rdt7080lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5c7c788f-e292-4ed5-b8b6-2d92179a1549"}}}}, {"uuid": "67d11589-d890-4924-88d4-c67f869a6f93", "name": "", "x": 38.561343164924004, "y": -122.50782854332392, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "161d4e7b-30f2-447c-a369-1bfa3ba2cd70", "name": "p1rlv15109", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "67d11589-d890-4924-88d4-c67f869a6f93"}}}}, {"uuid": "95c151ef-ad3e-4f24-a147-4c639e3a18d2", "name": "", "x": 38.56161341947106, "y": -122.5078037444857, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bb6d8f13-f04e-4b80-a8dc-e16af1dc860e", "name": "p1rlv15125", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "95c151ef-ad3e-4f24-a147-4c639e3a18d2"}}}}, {"uuid": "4b3c05ad-cedd-477b-93ed-febea5d5232f", "name": "", "x": 38.559858339047835, "y": -122.50687058401597, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d0c96fe-78c2-4303-ac5c-bbe440f19666", "name": "p1rdt7087lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4b3c05ad-cedd-477b-93ed-febea5d5232f"}}}}, {"uuid": "db357bf8-bd4f-49eb-b3b1-04933eed13f3", "name": "", "x": 38.56006676468359, "y": -122.5064714121144, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bdee6d84-9253-4fba-b713-3e41d706e999", "name": "p1rlv15163", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "db357bf8-bd4f-49eb-b3b1-04933eed13f3"}}}}, {"uuid": "7c2faef8-a10d-4e28-bc4d-8542fee740d0", "name": "", "x": 38.55723982473556, "y": -122.5059256790796, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0f1652e8-6cf7-43d4-8474-e61a74873675", "name": "p1rdt7088lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7c2faef8-a10d-4e28-bc4d-8542fee740d0"}}}}, {"uuid": "5715e666-b8a9-484f-ba5f-8126a94010c7", "name": "", "x": 38.55722600645399, "y": -122.50597665691777, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2d2f8fcb-c279-49d5-88be-39e6a1d1990b", "name": "p1rlv15170", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5715e666-b8a9-484f-ba5f-8126a94010c7"}}}}, {"uuid": "0b91e779-c081-46eb-ba57-0400b5966cb1", "name": "", "x": 38.55763186186392, "y": -122.50515401038457, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "73cfcce9-a925-4f29-9cde-6dd6f50735e1", "name": "p1rdt7089lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0b91e779-c081-46eb-ba57-0400b5966cb1"}}}}, {"uuid": "7645a840-49f1-4f3d-bf88-0d557ff10242", "name": "", "x": 38.5576058954936, "y": -122.50511142397353, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dc7cd505-823c-49bb-9e49-3681267dbef0", "name": "p1rlv15171", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7645a840-49f1-4f3d-bf88-0d557ff10242"}}}}, {"uuid": "1846601f-ea73-4a6d-b41f-f06723617295", "name": "", "x": 38.55819291339373, "y": -122.50729514639205, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5d6a4c80-d261-4350-8224-8fe5191459c7", "name": "p1rdt7090lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1846601f-ea73-4a6d-b41f-f06723617295"}}}}, {"uuid": "5f1f5eaa-fca2-4063-8623-d2c87240ac98", "name": "", "x": 38.558186799297566, "y": -122.50731063399988, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e218b01d-f713-4baf-9688-7e77ea413c8c", "name": "p1rlv15180", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5f1f5eaa-fca2-4063-8623-d2c87240ac98"}}}}, {"uuid": "d41eed58-eb05-4eb6-91b8-26ead7b42739", "name": "", "x": 38.643254518897194, "y": -122.45483995487372, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6718b871-3967-4c29-83e5-441799c7fb92", "name": "p1rdt7201lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d41eed58-eb05-4eb6-91b8-26ead7b42739"}}}}, {"uuid": "b9bae9e3-62cb-4c3b-a8b7-2fdb6158be87", "name": "", "x": 38.64314352984028, "y": -122.45483682254313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fd21ae8b-7841-43b4-871f-316c4b8b4cd2", "name": "p1rlv15394", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b9bae9e3-62cb-4c3b-a8b7-2fdb6158be87"}}}}, {"uuid": "8c6660ec-b375-4cc2-8f0d-b4269bbad1e5", "name": "", "x": 38.64359496143701, "y": -122.45501725670924, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5ec1f313-f341-498c-b1c2-6669b1cbc629", "name": "p1rlv15399", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8c6660ec-b375-4cc2-8f0d-b4269bbad1e5"}}}}, {"uuid": "862f0625-04be-4c1c-9407-0449f1b4e76d", "name": "", "x": 38.643369459814934, "y": -122.45497300119509, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8bc46399-0276-4ae7-aa8b-4cdd3d3555e8", "name": "p1rlv15419", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "862f0625-04be-4c1c-9407-0449f1b4e76d"}}}}, {"uuid": "6d0c0017-941d-496d-a360-3f767288ac7d", "name": "", "x": 38.643190246717545, "y": -122.45519268460242, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "335df4da-50d2-4fbe-a271-ac04257d35c7", "name": "p1rlv15478", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6d0c0017-941d-496d-a360-3f767288ac7d"}}}}, {"uuid": "f9f10379-c1aa-4451-908d-38eecfa2b445", "name": "", "x": 38.6429090279938, "y": -122.45418759719459, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "37ccfa64-1373-49b2-85f6-279abea3c945", "name": "p1rlv15523", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f9f10379-c1aa-4451-908d-38eecfa2b445"}}}}, {"uuid": "f75bd794-6d16-46ee-99bd-adaf4993874e", "name": "", "x": 38.64844611776415, "y": -122.46453889053006, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5d5e45d6-867a-4442-8258-2c04891dbc4b", "name": "p1rdt7220lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f75bd794-6d16-46ee-99bd-adaf4993874e"}}}}, {"uuid": "16ccf6c7-32c1-4714-b004-edbd0fcf2460", "name": "", "x": 38.64842013673824, "y": -122.46449626559803, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f9ca373a-b1c3-464d-bbe3-c05b728beb30", "name": "p1rlv15418", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "16ccf6c7-32c1-4714-b004-edbd0fcf2460"}}}}, {"uuid": "6226913c-7d7d-477d-95e9-54bb8abd2648", "name": "", "x": 38.64544505846416, "y": -122.42121162161781, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d6a6156f-e72a-41f0-a307-e6030de24fde", "name": "p1rdt7224lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6226913c-7d7d-477d-95e9-54bb8abd2648"}}}}, {"uuid": "27cb7911-2e9b-464c-93c0-ac632f6ff630", "name": "", "x": 38.64521777279914, "y": -122.42138184387917, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "921f8f54-ff83-4d2f-8bf4-ee80bab64ce8", "name": "p1rlv15487", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "27cb7911-2e9b-464c-93c0-ac632f6ff630"}}}}, {"uuid": "69b27ea4-60b0-4eda-81a3-4486c128089b", "name": "", "x": 38.64535123894055, "y": -122.42103603545684, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "79c5341b-3cd2-41a3-8bbf-e50857b00dae", "name": "p1rdm15891", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "69b27ea4-60b0-4eda-81a3-4486c128089b"}}}}, {"uuid": "09527da2-781f-41bf-b313-d35ece88a326", "name": "", "x": 38.64513570345144, "y": -122.42118715458822, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "26009a7e-9bfc-4967-af28-4d8937539eb1", "name": "p1rlv15423", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "09527da2-781f-41bf-b313-d35ece88a326"}}}}, {"uuid": "bb839b26-b6d1-4449-a1b9-452e490d2a89", "name": "", "x": 38.64529779575312, "y": -122.42116286827518, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "34e0ffc2-da17-441b-bd4d-26d5a1104712", "name": "p1rlv15474", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bb839b26-b6d1-4449-a1b9-452e490d2a89"}}}}, {"uuid": "a328fc38-9751-4e00-9895-2603399f0135", "name": "", "x": 38.648428944357136, "y": -122.46102923499245, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2087cee5-9f6e-4400-8ca8-bbb120cd4dae", "name": "p1rdt7248lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a328fc38-9751-4e00-9895-2603399f0135"}}}}, {"uuid": "750db3fa-bb1a-4d04-b712-ff839caf5bfb", "name": "", "x": 38.64843531677844, "y": -122.46107118044478, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "544be417-0db6-45a7-8314-ec40944781fa", "name": "p1rlv15466", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "750db3fa-bb1a-4d04-b712-ff839caf5bfb"}}}}, {"uuid": "862f5d4c-08c7-48f1-a229-70ced1db006d", "name": "", "x": 38.648497708978724, "y": -122.4609213210892, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3c4e3eac-0b1a-4feb-b39f-079c6d2c1d82", "name": "p1rlv15483", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "862f5d4c-08c7-48f1-a229-70ced1db006d"}}}}, {"uuid": "32bfc63e-f0fa-4281-8265-4295041aa664", "name": "", "x": 38.64803011681224, "y": -122.46114316554923, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6579cc93-2b08-4010-816d-3bef509000cd", "name": "p1rlv15488", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "32bfc63e-f0fa-4281-8265-4295041aa664"}}}}, {"uuid": "6a9646be-d91a-42e6-b44c-c57056f16ac4", "name": "", "x": 38.64867815080695, "y": -122.46096593584461, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b09822b3-a220-48ff-ad4f-62fca602f8b6", "name": "p1rlv15542", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a9646be-d91a-42e6-b44c-c57056f16ac4"}}}}, {"uuid": "009068dc-1050-4ede-85b3-38c88606ebaa", "name": "", "x": 38.64806971694897, "y": -122.4591176468453, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b4f7df4-5453-459d-8599-48fd5f29a9c6", "name": "p1rdt7253lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "009068dc-1050-4ede-85b3-38c88606ebaa"}}}}, {"uuid": "4f4045d5-a424-4828-8712-a5e2d27af07c", "name": "", "x": 38.6480437339618, "y": -122.45907502411583, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6749066f-4739-41ec-8369-8da49dd9e1c8", "name": "p1rlv15484", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4f4045d5-a424-4828-8712-a5e2d27af07c"}}}}, {"uuid": "ce488c5f-6b15-495e-a1dc-3e08aea6376a", "name": "", "x": 38.650849807011845, "y": -122.4260111114199, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1130272e-b98e-496f-aeb9-c094cf9cd824", "name": "p1rdt7268lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ce488c5f-6b15-495e-a1dc-3e08aea6376a"}}}}, {"uuid": "6a086fd3-e4a3-4194-82d1-3d55ac26d4a6", "name": "", "x": 38.650823812052785, "y": -122.42596849916298, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6eec860d-08cf-4690-93e6-d909429d363d", "name": "p1rlv15525", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a086fd3-e4a3-4194-82d1-3d55ac26d4a6"}}}}, {"uuid": "654a9de7-dcb0-4746-8171-280e65546dae", "name": "", "x": 38.56642393843708, "y": -122.500066081999, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d304e5e0-2cc1-4167-9fad-6fc72228d828", "name": "p1rdt7298lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "654a9de7-dcb0-4746-8171-280e65546dae"}}}}, {"uuid": "6a642350-2238-4a5c-825f-8e833548e191", "name": "", "x": 38.56639797023211, "y": -122.50002349228465, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "688da57a-6f10-4ef8-8763-202a88c3a495", "name": "p1rlv15603", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a642350-2238-4a5c-825f-8e833548e191"}}}}, {"uuid": "81704916-b78c-4299-8fc1-4958e3705545", "name": "", "x": 38.586910904171326, "y": -122.52012069769289, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "43df4c14-a198-4d51-87f4-80000198cd47", "name": "p1rdt7301lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "81704916-b78c-4299-8fc1-4958e3705545"}}}}, {"uuid": "9fcd0830-ea92-460e-88c4-2f39c88f4ed7", "name": "", "x": 38.58688494322849, "y": -122.52007808865979, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c32ce070-e690-4fc1-92ac-f857691de578", "name": "p1rlv15606", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9fcd0830-ea92-460e-88c4-2f39c88f4ed7"}}}}, {"uuid": "a00d66f5-e5d7-4a85-b1e2-41d52b447303", "name": "", "x": 38.56306853879527, "y": -122.5102770561152, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3e2a141f-436a-45c0-9c15-179301a439c8", "name": "p1rdt7302lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a00d66f5-e5d7-4a85-b1e2-41d52b447303"}}}}, {"uuid": "aa80928f-e27e-42d3-ab52-19e97aa61d61", "name": "", "x": 38.56308491307865, "y": -122.51055992850522, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32291502-d7be-4b45-8af7-cb217448e73f", "name": "p1rlv15607", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aa80928f-e27e-42d3-ab52-19e97aa61d61"}}}}, {"uuid": "cd52fc3f-b014-47cf-820c-b191189ba802", "name": "", "x": 38.563191661348114, "y": -122.51022633928095, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2715a637-d6f0-4e7b-b43e-20836bf4e614", "name": "p1rlv15638", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cd52fc3f-b014-47cf-820c-b191189ba802"}}}}, {"uuid": "62d95444-7296-4d3a-8cb0-3fa5dd858b1b", "name": "", "x": 38.56290700610434, "y": -122.51179679741092, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0926064a-1c87-450a-b282-23708de8aec4", "name": "p1rdt7306lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "62d95444-7296-4d3a-8cb0-3fa5dd858b1b"}}}}, {"uuid": "bf198d6d-a6e0-4737-a4e7-8a2939338d8d", "name": "", "x": 38.56368313784799, "y": -122.511382300603, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5ab2d6dc-f5bb-4320-86f3-bf08bb7cf93f", "name": "p1rlv15614", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bf198d6d-a6e0-4737-a4e7-8a2939338d8d"}}}}, {"uuid": "5fea1be8-832e-410d-af35-560129d549bc", "name": "", "x": 38.57387166576081, "y": -122.5068092396372, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6ce9dd2c-9e17-46b7-a6f4-e85077664432", "name": "p1rdt7307lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5fea1be8-832e-410d-af35-560129d549bc"}}}}, {"uuid": "e984cc18-d43d-4279-98ad-7a297ad808c9", "name": "", "x": 38.573802276520816, "y": -122.50677924408086, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6106bbe7-7a47-4c50-8b2a-d46d7432bccf", "name": "p1rlv15617", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e984cc18-d43d-4279-98ad-7a297ad808c9"}}}}, {"uuid": "60d115bb-a2f5-47fd-ad21-f774776aafdc", "name": "", "x": 38.573945931269776, "y": -122.50665198381543, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0bb184ad-cb26-4317-8c40-f2c8a9f80dab", "name": "p1rlv19146", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "60d115bb-a2f5-47fd-ad21-f774776aafdc"}}}}, {"uuid": "6243e000-7c2a-4199-aba2-ca01fe1b1dd7", "name": "", "x": 38.57392039558398, "y": -122.50700803276428, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "546433b3-d70e-49ed-9037-ec88adda79b9", "name": "p1rlv19147", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6243e000-7c2a-4199-aba2-ca01fe1b1dd7"}}}}, {"uuid": "1df6c2be-0b95-47ed-8ccf-650263d8acdb", "name": "", "x": 38.563303651285544, "y": -122.5126284769322, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e2d6046b-9ece-4295-a180-41bf2ce47ce6", "name": "p1rdt7311lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1df6c2be-0b95-47ed-8ccf-650263d8acdb"}}}}, {"uuid": "daba764b-a0fc-4c47-b9d1-f41023553bb6", "name": "", "x": 38.56384855592281, "y": -122.51215022095688, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1151b559-3ae0-4863-9363-9b395bbfc403", "name": "p1rlv15622", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "daba764b-a0fc-4c47-b9d1-f41023553bb6"}}}}, {"uuid": "1f14723b-86dc-4a46-a672-3ed1ff4b6072", "name": "", "x": 38.56815134225955, "y": -122.50546068410047, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "97844fdb-b016-4ca3-8777-b0553ead9297", "name": "p1rdt7314lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1f14723b-86dc-4a46-a672-3ed1ff4b6072"}}}}, {"uuid": "ea07bd82-2337-41b7-ac6c-4158f09b55a2", "name": "", "x": 38.56817687324023, "y": -122.50541766691859, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ec0bca53-a58b-4004-8dba-8defca9db4c7", "name": "p1rlv15629", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea07bd82-2337-41b7-ac6c-4158f09b55a2"}}}}, {"uuid": "502ec234-aaf7-4749-8910-9336c0c13d45", "name": "", "x": 38.56855471658057, "y": -122.50523980787194, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "22b1ecce-d5df-4f42-abb2-9f4c3d3a28c5", "name": "p1rdt7318lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "502ec234-aaf7-4749-8910-9336c0c13d45"}}}}, {"uuid": "7ae0df86-6d12-44d0-9fd4-967a2abacbfa", "name": "", "x": 38.568569050828, "y": -122.50529056187261, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a5af6dae-d20f-4a31-9544-b9455cd639bd", "name": "p1rlv15634", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7ae0df86-6d12-44d0-9fd4-967a2abacbfa"}}}}, {"uuid": "c125e674-85b7-4f60-93b0-24e4722e6cc3", "name": "", "x": 38.60115277629168, "y": -122.46102699453549, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "58be5cbe-5a7c-4fa5-972d-e03100b3bb46", "name": "p1rdt7550lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c125e674-85b7-4f60-93b0-24e4722e6cc3"}}}}, {"uuid": "d96464bf-d57f-4a79-95ab-73e600c00eb4", "name": "", "x": 38.60105048076314, "y": -122.46095488399553, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5984e209-9f0e-4844-91e6-902c8329f13c", "name": "p1rlv16114", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d96464bf-d57f-4a79-95ab-73e600c00eb4"}}}}, {"uuid": "f04f0ccb-57e8-461b-80fb-4acde4ab77df", "name": "", "x": 38.60120431220644, "y": -122.46109154303083, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "807b0bef-0d34-44a9-a2a9-0c0a11f4ea8e", "name": "p1rlv16178", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f04f0ccb-57e8-461b-80fb-4acde4ab77df"}}}}, {"uuid": "6b7c2c76-7774-48ee-910e-81eb26d11585", "name": "", "x": 38.60318695205525, "y": -122.45853113684389, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1c4d7ee3-fc5d-4a17-a717-3d6b6d5a67ae", "name": "p1rdt7551lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6b7c2c76-7774-48ee-910e-81eb26d11585"}}}}, {"uuid": "6cf6c48f-0c39-4e82-aaa5-9850a4ea3d6c", "name": "", "x": 38.6034004318743, "y": -122.45853704613184, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "52d1b79d-5c6b-4b44-9998-600c6debd999", "name": "p1rlv16115", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6cf6c48f-0c39-4e82-aaa5-9850a4ea3d6c"}}}}, {"uuid": "ce389c53-ae3e-4477-bd2e-926434e7d3c2", "name": "", "x": 38.60293177722496, "y": -122.45852908328547, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6efff4f7-c67b-4cfb-a72d-30b6616825b1", "name": "p1rlv16157", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ce389c53-ae3e-4477-bd2e-926434e7d3c2"}}}}, {"uuid": "86be8abe-cfa1-408c-9fae-445d6897801f", "name": "", "x": 38.601851120199065, "y": -122.45542100224573, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1f5d6708-cef4-4aac-9fa0-c738953c788f", "name": "p1rdt7552lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "86be8abe-cfa1-408c-9fae-445d6897801f"}}}}, {"uuid": "7d645f59-ab39-476e-b903-ae66856dfb97", "name": "", "x": 38.60199783561238, "y": -122.45535495885304, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "972f8088-b67b-47d0-a86f-49179dfb1c92", "name": "p1rlv16116", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7d645f59-ab39-476e-b903-ae66856dfb97"}}}}, {"uuid": "5306fedc-377c-405e-8294-70ab141da9c9", "name": "", "x": 38.60173719494335, "y": -122.45550622371668, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "92a37082-36d4-4eca-95e4-88dbcacd6db5", "name": "p1rlv16197", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5306fedc-377c-405e-8294-70ab141da9c9"}}}}, {"uuid": "2f0e73df-0c62-40a8-a734-286365ac0370", "name": "", "x": 38.60639320900444, "y": -122.45582291610495, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e7a672b2-d127-4fb5-8cc4-8115b8ef3f60", "name": "p1rdt7553lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2f0e73df-0c62-40a8-a734-286365ac0370"}}}}, {"uuid": "9c579c2e-db54-4d6b-906e-b3e3396c2a73", "name": "", "x": 38.606405183855294, "y": -122.45547094869913, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "204899ec-81e4-4a72-bf70-69b3428a49a1", "name": "p1rlv16117", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9c579c2e-db54-4d6b-906e-b3e3396c2a73"}}}}, {"uuid": "2bf36cf3-92b0-4202-afe5-e4a82e38ea10", "name": "", "x": 38.60746648825486, "y": -122.45829224306911, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "86a6d184-d883-4e27-aee5-b89c82163284", "name": "p1rdt7554lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2bf36cf3-92b0-4202-afe5-e4a82e38ea10"}}}}, {"uuid": "2df0eb30-a882-4def-ab77-29e11f4fd85d", "name": "", "x": 38.60753796176142, "y": -122.45877011077201, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bca0b3a0-d4cb-4a4a-9b14-aa23d9e5e5fe", "name": "p1rlv16118", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2df0eb30-a882-4def-ab77-29e11f4fd85d"}}}}, {"uuid": "c4771003-2c0d-47fc-bf08-901d4c211e51", "name": "", "x": 38.60761943761314, "y": -122.45884989486198, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c840cf3f-be15-448b-8c03-8942c586b135", "name": "p1rlv16139", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c4771003-2c0d-47fc-bf08-901d4c211e51"}}}}, {"uuid": "14b6738b-41dd-4f20-ab31-7fd70218af0b", "name": "", "x": 38.60732511225313, "y": -122.45756577239354, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "68aa5cc5-f6bf-4417-8653-747c56b37b5e", "name": "p1rlv16201", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "14b6738b-41dd-4f20-ab31-7fd70218af0b"}}}}, {"uuid": "0b85b1e3-d355-43b8-8b7a-6468a77acd10", "name": "", "x": 38.60729988695483, "y": -122.45795645616205, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf413742-18c8-483d-b8f1-f125f95323da", "name": "p1rlv16209", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0b85b1e3-d355-43b8-8b7a-6468a77acd10"}}}}, {"uuid": "988e9a2d-9ed8-4c63-b121-042df9ce3188", "name": "", "x": 38.599910107670105, "y": -122.4605115694972, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0de9c581-b78b-44d6-8693-59b995e2a3bb", "name": "p1rdt7555lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "988e9a2d-9ed8-4c63-b121-042df9ce3188"}}}}, {"uuid": "53064509-7052-4af7-87fe-e13f6ad6d921", "name": "", "x": 38.60005645544839, "y": -122.46036515331646, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c0d6e608-d5bf-40d6-9efd-f3b0922e7d77", "name": "p1rlv16119", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "53064509-7052-4af7-87fe-e13f6ad6d921"}}}}, {"uuid": "7829fac3-fe6e-4708-aebe-204569ca6f84", "name": "", "x": 38.607794956621454, "y": -122.45548336703727, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0b593ec6-e1e3-48c2-b352-f7966f206aa9", "name": "p1rdt7559lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7829fac3-fe6e-4708-aebe-204569ca6f84"}}}}, {"uuid": "84d7a033-8e7b-4fb0-9cc0-c8644b232b05", "name": "", "x": 38.60770977446864, "y": -122.45501316679001, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6da4b2d0-66c7-43fb-9aab-3bbac03aa989", "name": "p1rlv16124", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "84d7a033-8e7b-4fb0-9cc0-c8644b232b05"}}}}, {"uuid": "cb0b839a-cd6f-491d-932b-83f7ff4c8736", "name": "", "x": 38.60025024332015, "y": -122.46073516079042, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "05e30abd-3c40-4dbd-9261-ca8a8abd9c56", "name": "p1rdt7561lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb0b839a-cd6f-491d-932b-83f7ff4c8736"}}}}, {"uuid": "e788a403-3ee0-4bc1-83e8-447ea9a8a20a", "name": "", "x": 38.60030209684127, "y": -122.46086860989422, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bd41f55a-4b5d-4c19-9787-801072b3b946", "name": "p1rlv16126", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e788a403-3ee0-4bc1-83e8-447ea9a8a20a"}}}}, {"uuid": "4124fd29-4733-49fc-a471-b50ad153de68", "name": "", "x": 38.60042704179853, "y": -122.46060354272663, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "102b9460-ea9a-4099-b16f-40b8fdf99ef7", "name": "p1rlv16133", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4124fd29-4733-49fc-a471-b50ad153de68"}}}}, {"uuid": "0d6f3592-9121-45e3-9cbe-84457185ba70", "name": "", "x": 38.60180967142113, "y": -122.46424249788332, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f7588b3b-f54c-483d-b354-b9908483019a", "name": "p1rdt7564lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0d6f3592-9121-45e3-9cbe-84457185ba70"}}}}, {"uuid": "8dec918d-10ab-432a-b8bb-e415a12f101b", "name": "", "x": 38.60183518685866, "y": -122.46419944605898, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "676de1a3-2dfd-4faa-a057-7739e825d136", "name": "p1rlv16135", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8dec918d-10ab-432a-b8bb-e415a12f101b"}}}}, {"uuid": "31d60c7f-e3f0-4686-8e19-b56bd4e1464a", "name": "", "x": 38.6078075576706, "y": -122.45772713266135, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f2b3b9e1-3d98-44c1-bd38-9325623a1553", "name": "p1rdt7570lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "31d60c7f-e3f0-4686-8e19-b56bd4e1464a"}}}}, {"uuid": "fa7474fe-414e-4687-8d13-9b47b7f5bf2e", "name": "", "x": 38.60779838775444, "y": -122.45777980644779, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6d21c357-1033-45e1-84a0-b82ceafe6ab8", "name": "p1rlv16146", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa7474fe-414e-4687-8d13-9b47b7f5bf2e"}}}}, {"uuid": "14c8ea02-6b8a-4683-a209-b207e62df26b", "name": "", "x": 38.60626762047214, "y": -122.45581795786703, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "69bf048e-54cd-4e41-a23e-485b0cd98fae", "name": "p1rdt7572lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "14c8ea02-6b8a-4683-a209-b207e62df26b"}}}}, {"uuid": "2814eb4a-ef43-4726-81b5-35cb10bb963a", "name": "", "x": 38.60645647275145, "y": -122.45487334223284, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b15792ca-a6bd-47e5-8c67-5c3076174848", "name": "p1rlv16149", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2814eb4a-ef43-4726-81b5-35cb10bb963a"}}}}, {"uuid": "84a70399-13e1-4ea7-b2cd-5a587410bf53", "name": "", "x": 38.60650078143132, "y": -122.45471221720932, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1aacea55-115d-46c3-9590-725cf5040f38", "name": "p1rlv16200", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "84a70399-13e1-4ea7-b2cd-5a587410bf53"}}}}, {"uuid": "644491c8-32e3-415d-a8b2-9cdc7acd7dfa", "name": "", "x": 38.606181337381166, "y": -122.4557827336667, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33a848c7-076e-4025-863b-ce9151bcc3ac", "name": "p1rdm16630", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "644491c8-32e3-415d-a8b2-9cdc7acd7dfa"}}}}, {"uuid": "1cd42c9f-87d5-443d-bc3d-baf635075a0e", "name": "", "x": 38.60633132723502, "y": -122.45509250327417, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b85e180a-8eb4-4acc-a816-d99758cc16ea", "name": "p1rlv16158", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1cd42c9f-87d5-443d-bc3d-baf635075a0e"}}}}, {"uuid": "756f2ab1-9338-45a3-9e5c-bf0de418e671", "name": "", "x": 38.60650742609989, "y": -122.45740736442846, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a742708-0f8b-42d0-a977-b5ce5e36a042", "name": "p1rdt7574lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "756f2ab1-9338-45a3-9e5c-bf0de418e671"}}}}, {"uuid": "b72df13b-b760-4f9c-8e84-7384a4026df1", "name": "", "x": 38.606502198240534, "y": -122.45735394894129, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "74edd9e9-24a5-4b36-8ca8-24ef2fa3e972", "name": "p1rlv16156", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b72df13b-b760-4f9c-8e84-7384a4026df1"}}}}, {"uuid": "bd429532-7ff5-4e19-8118-d02b72b2445d", "name": "", "x": 38.59916576086806, "y": -122.46399319639457, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "56b05024-7907-458d-a5c3-0e54ffbabdb5", "name": "p1rdt7576lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bd429532-7ff5-4e19-8118-d02b72b2445d"}}}}, {"uuid": "7198a865-1cfe-44a8-8fab-751b1cc8a6af", "name": "", "x": 38.59972953494432, "y": -122.46374387036614, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4fb5abb7-dd79-49aa-9185-88a90bb45bc7", "name": "p1rlv16168", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7198a865-1cfe-44a8-8fab-751b1cc8a6af"}}}}, {"uuid": "89474c6b-5738-4943-9265-a4fb35b3a0a5", "name": "", "x": 38.603712525417045, "y": -122.46283870922412, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4d00b7fe-0384-4c12-a0cf-8895458d3b80", "name": "p1rdt7579lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "89474c6b-5738-4943-9265-a4fb35b3a0a5"}}}}, {"uuid": "332633b6-3eb5-4d54-8439-cfecf21faba5", "name": "", "x": 38.60368654376888, "y": -122.46279611119927, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cbbe8401-53a1-4ce7-9ce1-02f547055d95", "name": "p1rlv16177", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "332633b6-3eb5-4d54-8439-cfecf21faba5"}}}}, {"uuid": "e75397fa-6344-480e-8b24-b7e3fb47e90b", "name": "", "x": 38.601513560330964, "y": -122.46255652294417, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "abc940b0-c9f5-4582-adaf-ad7f4a79a35f", "name": "p1rdt7588lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e75397fa-6344-480e-8b24-b7e3fb47e90b"}}}}, {"uuid": "1dbfb486-355e-48bb-9547-1c5af9aab2e8", "name": "", "x": 38.601499761325734, "y": -122.46260754027634, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0ca42395-8d67-4e83-80ec-159cacb490f8", "name": "p1rlv16206", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1dbfb486-355e-48bb-9547-1c5af9aab2e8"}}}}, {"uuid": "f01e60a2-6edb-4fa2-90ef-fa24804682ad", "name": "", "x": 38.63266298601826, "y": -122.4216856102529, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "53e9cf92-1c91-428f-bdff-64257257ad5b", "name": "p1rdt7589lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f01e60a2-6edb-4fa2-90ef-fa24804682ad"}}}}, {"uuid": "4e04d8fd-20ec-4f89-8bbf-cf16549031aa", "name": "", "x": 38.632738611285475, "y": -122.42182684518295, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9fd05f3c-df77-45bc-8686-458b681a3d08", "name": "p1rlv16210", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4e04d8fd-20ec-4f89-8bbf-cf16549031aa"}}}}, {"uuid": "6dea6e95-aba5-4fce-b04c-34f7c28df0ab", "name": "", "x": 38.63262911078122, "y": -122.4215519854009, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "56b91b3f-dfdd-41bf-9d2e-a8183077c752", "name": "p1rlv16235", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6dea6e95-aba5-4fce-b04c-34f7c28df0ab"}}}}, {"uuid": "226e95df-79cb-49c6-99eb-7ce9f9be1eda", "name": "", "x": 38.63109043622211, "y": -122.42673165565434, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ff1e0d26-d845-43c3-9aaf-01d1c007b9a1", "name": "p1rdt7598lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "226e95df-79cb-49c6-99eb-7ce9f9be1eda"}}}}, {"uuid": "a34d4271-e724-4b08-9a1e-9e75013aa774", "name": "", "x": 38.631104804579536, "y": -122.42678243753235, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b9761003-33fa-482a-967b-b508ab67c19f", "name": "p1rlv16221", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a34d4271-e724-4b08-9a1e-9e75013aa774"}}}}, {"uuid": "7115795f-d38c-435c-bd32-d79fd0c3e2be", "name": "", "x": 38.59926349646212, "y": -122.48320976110043, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d838502-3769-4d70-839b-26fd628ce478", "name": "p1rdt7599lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7115795f-d38c-435c-bd32-d79fd0c3e2be"}}}}, {"uuid": "c3f465b9-0d5a-4166-b70d-0b31c3a84cab", "name": "", "x": 38.59924968840877, "y": -122.4832607729825, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4809afc1-2d3d-491d-80e5-9cd4e8da08f2", "name": "p1rlv16222", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c3f465b9-0d5a-4166-b70d-0b31c3a84cab"}}}}, {"uuid": "7e356edd-9a1e-4a20-b1e2-05ff729a0ab9", "name": "", "x": 38.63045512607571, "y": -122.42581761149648, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d3488ff0-696f-4180-bc70-41ff37f9c365", "name": "p1rdt7605lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7e356edd-9a1e-4a20-b1e2-05ff729a0ab9"}}}}, {"uuid": "dba9df17-dbb7-40e0-8389-32f86a83d0ce", "name": "", "x": 38.63042913104939, "y": -122.4257750112935, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b8767650-39c5-4d4a-80ce-af408c246599", "name": "p1rlv16228", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dba9df17-dbb7-40e0-8389-32f86a83d0ce"}}}}, {"uuid": "ba3209f3-ddc3-42d2-9fb6-73352cdcc890", "name": "", "x": 38.62802329409922, "y": -122.420609783299, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0fdfea70-187a-4bbc-ba3f-69cb74c4d5c5", "name": "p1rdt7612lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ba3209f3-ddc3-42d2-9fb6-73352cdcc890"}}}}, {"uuid": "f517027f-3138-4efe-b5c1-6b209dd16b66", "name": "", "x": 38.62799729719169, "y": -122.42056718642846, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9642fa30-e5f7-42f1-8fda-ab75a265d25a", "name": "p1rlv16239", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f517027f-3138-4efe-b5c1-6b209dd16b66"}}}}, {"uuid": "eae6de67-8927-41f1-b2b4-566cb14958c4", "name": "", "x": 38.56073046128886, "y": -122.50852889395006, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "269e9ba5-bc54-4cbd-9140-4b1bea74fc53", "name": "p1rdt7615lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eae6de67-8927-41f1-b2b4-566cb14958c4"}}}}, {"uuid": "dfa27b4c-8f60-4a6f-8e32-e240e90c01fa", "name": "", "x": 38.56046440447144, "y": -122.50887900476087, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e82036d9-e6c8-42c3-b45b-30bef6902bbc", "name": "p1rlv16242", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dfa27b4c-8f60-4a6f-8e32-e240e90c01fa"}}}}, {"uuid": "6ee0bd86-1680-444a-a29c-1dc0ca96d7f2", "name": "", "x": 38.56073966572795, "y": -122.50857474214654, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "978533ca-ef57-4cb6-9e7f-b3c6d1bbd7d5", "name": "p1rlv16261", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6ee0bd86-1680-444a-a29c-1dc0ca96d7f2"}}}}, {"uuid": "47348236-35ea-4e14-9db4-04f53ff4cb88", "name": "", "x": 38.562034810135316, "y": -122.51158858609705, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "65458dd3-50e0-48d3-a0db-0015707d3cea", "name": "p1rdm16694", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "47348236-35ea-4e14-9db4-04f53ff4cb88"}}}}, {"uuid": "51f24211-6a02-4069-9407-7162a0e828bf", "name": "", "x": 38.56202613361287, "y": -122.51166899029859, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "268549c6-0c8b-44ac-b933-316b36645366", "name": "p1rlv16253", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "51f24211-6a02-4069-9407-7162a0e828bf"}}}}, {"uuid": "84b11cd9-6ad0-4a24-a958-715b6fc7be35", "name": "", "x": 38.56186788179104, "y": -122.51113810898512, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6af13868-ecb1-4110-be3f-537741287035", "name": "p1rdt7616lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "84b11cd9-6ad0-4a24-a958-715b6fc7be35"}}}}, {"uuid": "7d5808cb-7939-481a-8de5-91a65946aa43", "name": "", "x": 38.56181598959075, "y": -122.51098173878029, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "83d31d7a-8900-4f2e-9183-8a10f07e2bdd", "name": "p1rdm16695", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7d5808cb-7939-481a-8de5-91a65946aa43"}}}}, {"uuid": "9e3cb4e1-00a3-40b7-a310-e1d3288381c9", "name": "", "x": 38.561797870283755, "y": -122.51095890578438, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c620d4b9-a849-4bf6-b108-118836866602", "name": "p1rlv16270", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9e3cb4e1-00a3-40b7-a310-e1d3288381c9"}}}}, {"uuid": "301d7474-7394-4adb-83c5-de8da079d030", "name": "", "x": 38.56163474835187, "y": -122.51074193179929, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "766647d4-7c3c-4058-b30c-dbc593b88ecb", "name": "p1rdm16693", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "301d7474-7394-4adb-83c5-de8da079d030"}}}}, {"uuid": "ee0e3777-b5c5-4c55-8a82-0a2aa0ec819c", "name": "", "x": 38.56165286770099, "y": -122.51076476468909, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "20818cc7-617e-4ab7-8f7c-31eea6496a02", "name": "p1rlv16243", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ee0e3777-b5c5-4c55-8a82-0a2aa0ec819c"}}}}, {"uuid": "effa99d5-0528-4214-9f65-c85da4d99cb0", "name": "", "x": 38.563138374369146, "y": -122.50973711139406, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4be4af94-fee7-40d6-9061-9a0fe0e7377e", "name": "p1rdt7617lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "effa99d5-0528-4214-9f65-c85da4d99cb0"}}}}, {"uuid": "daf01f10-6d6c-445b-9fdd-f5006c1c211b", "name": "", "x": 38.56309099533974, "y": -122.50985972349204, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e0164339-acc1-4b95-aa31-3af42cf943f7", "name": "p1rlv16244", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "daf01f10-6d6c-445b-9fdd-f5006c1c211b"}}}}, {"uuid": "53d2cce6-a3d7-4ce1-b40e-37e98b714398", "name": "", "x": 38.563135188623946, "y": -122.50965281749981, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4d1fb8eb-57aa-4366-afe5-b79174f3a4c7", "name": "p1rdm16697", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "53d2cce6-a3d7-4ce1-b40e-37e98b714398"}}}}, {"uuid": "767e8d01-6f03-4aab-bbdd-e7516fac9674", "name": "", "x": 38.563267563002256, "y": -122.50965942729142, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "04647fad-19dc-4ed8-8820-aa312674145c", "name": "p1rlv16255", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "767e8d01-6f03-4aab-bbdd-e7516fac9674"}}}}, {"uuid": "e6e642bd-5a02-4bab-9654-a8d16102dcd4", "name": "", "x": 38.64626899154278, "y": -122.41892573953396, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "795f4296-7c54-4e96-8468-52903af39708", "name": "p1rdm16699", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e6e642bd-5a02-4bab-9654-a8d16102dcd4"}}}}, {"uuid": "75f5fcc1-c81f-49ae-a4c9-1fe46bb70e41", "name": "", "x": 38.64646884092825, "y": -122.4192458831601, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5c6a5f39-0654-4e73-8050-c6c4ad9d54e6", "name": "p1rlv16252", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "75f5fcc1-c81f-49ae-a4c9-1fe46bb70e41"}}}}, {"uuid": "86e7ee95-7549-4c76-908c-030d93ec9795", "name": "", "x": 38.64614340209092, "y": -122.41904166679946, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "acb015a8-a9f8-492b-ab3f-b107bd956f91", "name": "p1rdm16698", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "86e7ee95-7549-4c76-908c-030d93ec9795"}}}}, {"uuid": "cb0a2f85-7a50-463d-bb48-789ac1c19a51", "name": "", "x": 38.646106728547146, "y": -122.41891555875277, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3783c838-b72e-42cd-8b0b-3005bca3cf5e", "name": "p1rlv16245", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb0a2f85-7a50-463d-bb48-789ac1c19a51"}}}}, {"uuid": "4a2288ec-9b7d-4dba-b1ba-c617235fedd4", "name": "", "x": 38.64641551310019, "y": -122.41882510751344, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "49f37435-54fc-42b4-baba-94f0611c8c76", "name": "p1rdt7618lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4a2288ec-9b7d-4dba-b1ba-c617235fedd4"}}}}, {"uuid": "25ca9092-333a-4071-952e-beb0df30161f", "name": "", "x": 38.64677146238617, "y": -122.41848500827774, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "73030a97-0574-4802-80d1-14fefeafa63a", "name": "p1rdm16700", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "25ca9092-333a-4071-952e-beb0df30161f"}}}}, {"uuid": "7a39814a-94fc-4129-9a0b-165f7813be33", "name": "", "x": 38.64669874248704, "y": -122.41835919083687, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "19aeb510-ac0e-4279-8db0-8de282beccc8", "name": "p1rlv16267", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7a39814a-94fc-4129-9a0b-165f7813be33"}}}}, {"uuid": "0630d605-bb3f-43f0-b776-d4ada20f11aa", "name": "", "x": 38.56141189302572, "y": -122.50849775727877, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3a205379-48f9-444c-baf8-dc84fc9c6d8a", "name": "p1rdt7619lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0630d605-bb3f-43f0-b776-d4ada20f11aa"}}}}, {"uuid": "15292442-11f0-4f4b-8858-9f1431a817b7", "name": "", "x": 38.561113439797154, "y": -122.50892049903847, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dd2dc2db-787a-4732-bae4-01186082a92d", "name": "p1rlv16246", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "15292442-11f0-4f4b-8858-9f1431a817b7"}}}}, {"uuid": "7388c6fa-ce1e-47ab-a43a-73bf44b2dacd", "name": "", "x": 38.56276173762939, "y": -122.51370313533468, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9af91c50-929d-4ac6-9272-7c44d17a0094", "name": "p1rdt7620lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7388c6fa-ce1e-47ab-a43a-73bf44b2dacd"}}}}, {"uuid": "90982ae6-16f2-483c-944a-57039dcebb07", "name": "", "x": 38.56259236273701, "y": -122.5134672071745, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a8d5e9b7-dc95-41f9-8547-99d5e2eba874", "name": "p1rlv16247", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "90982ae6-16f2-483c-944a-57039dcebb07"}}}}, {"uuid": "5106ecc5-1a2f-41bc-b6c8-3ae15176b9e9", "name": "", "x": 38.56176044882826, "y": -122.50995307443512, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60f0bddf-6e4b-495c-a98d-f3940d69a5e9", "name": "p1rdt7621lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5106ecc5-1a2f-41bc-b6c8-3ae15176b9e9"}}}}, {"uuid": "97ebfd06-ca63-41d2-ae54-9e9c8da085a2", "name": "", "x": 38.561693460357375, "y": -122.50969704739022, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "feb24768-feab-40f0-acc3-0b2bb500133a", "name": "p1rlv16248", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "97ebfd06-ca63-41d2-ae54-9e9c8da085a2"}}}}, {"uuid": "5ced85f7-f461-4760-989d-da3f0b33b912", "name": "", "x": 38.63755744615242, "y": -122.465948154899, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e2075fb-9691-447e-9a73-f88649310bc1", "name": "p1rdt7624lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ced85f7-f461-4760-989d-da3f0b33b912"}}}}, {"uuid": "5bc50684-7a0d-436b-972b-fe999f8f51db", "name": "", "x": 38.63754827273094, "y": -122.46600084949326, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32a9302f-2d40-4c2a-bde9-e4039694fed7", "name": "p1rlv16256", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5bc50684-7a0d-436b-972b-fe999f8f51db"}}}}, {"uuid": "cbff86f3-b1ca-4bb9-b929-b7706ddb1140", "name": "", "x": 38.56312481406225, "y": -122.50942641108807, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a6b1e3b6-ce3a-4ad6-a046-6608530b2ec2", "name": "p1rdt7625lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cbff86f3-b1ca-4bb9-b929-b7706ddb1140"}}}}, {"uuid": "ca85a7fc-d2bf-4ae4-bde9-edd5d0c42655", "name": "", "x": 38.56379044489856, "y": -122.50902854183389, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "935c99a6-bef6-4417-872c-0685011c440c", "name": "p1rlv16257", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ca85a7fc-d2bf-4ae4-bde9-edd5d0c42655"}}}}, {"uuid": "9094241e-f572-4ca2-a2f7-73618f62dfb3", "name": "", "x": 38.5622508740622, "y": -122.51221444287553, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "56f8eed1-77ae-4d65-80aa-7ae148350333", "name": "p1rdt7626lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9094241e-f572-4ca2-a2f7-73618f62dfb3"}}}}, {"uuid": "40f7128c-ed34-4a06-8927-100507e5ed27", "name": "", "x": 38.562245476566225, "y": -122.51240209551142, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fdf35585-e2b3-4463-a6a8-acb352f25003", "name": "p1rlv16260", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "40f7128c-ed34-4a06-8927-100507e5ed27"}}}}, {"uuid": "6de641fa-7013-4aa1-9223-c0f5bcdcc02b", "name": "", "x": 38.56232619942912, "y": -122.51230972629801, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fc746539-662a-4fe4-8774-6ba2dc538118", "name": "p1rlv16269", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6de641fa-7013-4aa1-9223-c0f5bcdcc02b"}}}}, {"uuid": "00cd9384-7f49-423e-b329-029dcc4041a7", "name": "", "x": 38.56258212321864, "y": -122.51385355991457, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "90d8891c-6e6d-46b9-8f88-acc9453c6541", "name": "p1rdt7627lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "00cd9384-7f49-423e-b329-029dcc4041a7"}}}}, {"uuid": "124e10ea-1bf0-41b7-a040-a7913288ddea", "name": "", "x": 38.562602805051284, "y": -122.51381147731462, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2797febc-f5e7-4cb3-b26f-ace990dc6920", "name": "p1rlv16262", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "124e10ea-1bf0-41b7-a040-a7913288ddea"}}}}, {"uuid": "e8a8f728-47d8-4295-b6f3-42e071ca524f", "name": "", "x": 38.56133819555369, "y": -122.51026584276248, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ad2599f-313b-49c6-abaa-19177e1a9edc", "name": "p1rdt7630lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e8a8f728-47d8-4295-b6f3-42e071ca524f"}}}}, {"uuid": "6fb5ec76-7803-4c02-9ae4-bb649280dfc2", "name": "", "x": 38.56092456814972, "y": -122.50968682475795, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e8835446-b333-4be9-96bd-57ff9d01ebd3", "name": "p1rlv16266", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6fb5ec76-7803-4c02-9ae4-bb649280dfc2"}}}}, {"uuid": "86853692-b205-4618-a7a5-8176c8cb9876", "name": "", "x": 38.5616967364387, "y": -122.50900438404291, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4861056b-b634-4900-94bb-d6c995387351", "name": "p1rdt7631lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "86853692-b205-4618-a7a5-8176c8cb9876"}}}}, {"uuid": "eb7a2999-86c8-4f6f-a010-1615b513d664", "name": "", "x": 38.561466725079015, "y": -122.50935425276774, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ba6ebe7f-b6b9-4f89-8bbf-7bffd63e10ef", "name": "p1rlv16268", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eb7a2999-86c8-4f6f-a010-1615b513d664"}}}}, {"uuid": "3398e448-e018-40e6-a50b-4504d0b77a7b", "name": "", "x": 38.637592171075106, "y": -122.45349611008078, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bfa76dc8-4007-4e52-9692-2eec7cb574e0", "name": "p1rdt7699lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3398e448-e018-40e6-a50b-4504d0b77a7b"}}}}, {"uuid": "dcb8b703-4cb4-4039-9993-9d9b04402c41", "name": "", "x": 38.63759072492407, "y": -122.45258089846875, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f58421d6-268b-417f-a579-c9c51d010697", "name": "p1rlv16416", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dcb8b703-4cb4-4039-9993-9d9b04402c41"}}}}, {"uuid": "1e841da1-29f5-41d4-8ba5-c88ecf63ee18", "name": "", "x": 38.63777525230912, "y": -122.45349869276687, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e60bfe9e-d2fa-4576-87f3-0a866b88d07d", "name": "p1rdm16862", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1e841da1-29f5-41d4-8ba5-c88ecf63ee18"}}}}, {"uuid": "37827724-bd74-4a74-8d3f-92058b8bebf4", "name": "", "x": 38.63771801473168, "y": -122.45282121950886, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9d908890-4fe4-4349-92de-464c4165b185", "name": "p1rlv16395", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "37827724-bd74-4a74-8d3f-92058b8bebf4"}}}}, {"uuid": "8e7d6de1-f6ed-4806-9ef0-24d1d6dbbf11", "name": "", "x": 38.636816322579385, "y": -122.45331816430568, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0cc95d09-c799-488e-81e8-50326a7da1ea", "name": "p1rdt7701lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8e7d6de1-f6ed-4806-9ef0-24d1d6dbbf11"}}}}, {"uuid": "db27e2bb-978f-4758-9ed3-644b0176ec4d", "name": "", "x": 38.63714867725408, "y": -122.45248085191842, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "323373a9-8e7d-4fb4-8970-dcc0e6d26c98", "name": "p1rlv16397", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "db27e2bb-978f-4758-9ed3-644b0176ec4d"}}}}, {"uuid": "5762879f-fed8-408b-b69c-2693dac42fd6", "name": "", "x": 38.634315239366806, "y": -122.45108169056164, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8ef392d6-b408-4a7f-8a67-9fe43e1df582", "name": "p1rdt7704lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5762879f-fed8-408b-b69c-2693dac42fd6"}}}}, {"uuid": "dbfb266a-0b63-477e-8649-ac94dbb2b196", "name": "", "x": 38.63384513963928, "y": -122.45197349911196, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "571a4c92-95b6-4bc0-a25d-0d9239a41a89", "name": "p1rlv20070", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dbfb266a-0b63-477e-8649-ac94dbb2b196"}}}}, {"uuid": "0e217484-8e6b-4d4d-af52-4413a7a594c3", "name": "", "x": 38.634430184568174, "y": -122.45121471447422, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0797f1d0-3499-4f88-a749-fc576240f791", "name": "p1rdm16872", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0e217484-8e6b-4d4d-af52-4413a7a594c3"}}}}, {"uuid": "fa4839ee-ecfc-4d14-8f46-c4b0651ff87c", "name": "", "x": 38.63430515491296, "y": -122.45145694554178, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eeb598c2-f0b9-44df-bfaa-be66e4dc3920", "name": "p1rlv16401", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa4839ee-ecfc-4d14-8f46-c4b0651ff87c"}}}}, {"uuid": "a9f961bd-cefe-4dae-ab39-0e189f5bff80", "name": "", "x": 38.63414958801971, "y": -122.4509525977873, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c5e00667-6368-49d3-a5dd-c574c79dba21", "name": "p1rdm16873", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a9f961bd-cefe-4dae-ab39-0e189f5bff80"}}}}, {"uuid": "1481206c-4e04-432b-a9f1-67ab90498892", "name": "", "x": 38.63394415582507, "y": -122.45134480308546, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d0b689f0-d4b1-4419-bff8-f72436625c60", "name": "p1rlv20068", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1481206c-4e04-432b-a9f1-67ab90498892"}}}}, {"uuid": "e97df275-6dc5-479d-a4d3-e0c412bde049", "name": "", "x": 38.633795319458095, "y": -122.45167161174345, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3f0e3c74-2d63-4612-b0e5-d986ebee0086", "name": "p1rlv20069", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e97df275-6dc5-479d-a4d3-e0c412bde049"}}}}, {"uuid": "a1266fd6-c0ee-49b8-82fc-cc6fce9a2e1b", "name": "", "x": 38.63640935476333, "y": -122.45301103214067, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "59a62487-c709-428e-9e97-c7c285a1305c", "name": "p1rdt7712lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a1266fd6-c0ee-49b8-82fc-cc6fce9a2e1b"}}}}, {"uuid": "5ad66ee7-9785-4523-a2f9-c52cd5d0b5a8", "name": "", "x": 38.636725727850084, "y": -122.45261045736181, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "99f97a6b-4e94-4a35-ad00-12e7004ab5e3", "name": "p1rlv16412", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ad66ee7-9785-4523-a2f9-c52cd5d0b5a8"}}}}, {"uuid": "3d37469f-053d-4c17-a339-a46fa2bfeb6a", "name": "", "x": 38.634298404574224, "y": -122.452544518945, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f6d10a4e-e7bc-4448-bca3-a5f2117b6198", "name": "p1rdt7718lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3d37469f-053d-4c17-a339-a46fa2bfeb6a"}}}}, {"uuid": "74a7237e-d8c7-411c-83b2-d4013f798b7a", "name": "", "x": 38.63419311757913, "y": -122.45254929248175, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f367b63c-c4cb-4810-a270-8bd0153b7b32", "name": "p1rlv16422", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "74a7237e-d8c7-411c-83b2-d4013f798b7a"}}}}, {"uuid": "4bac0a18-2477-438a-94a0-812507fc8fcd", "name": "", "x": 38.634445386111494, "y": -122.4525358843223, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c2242f1c-542f-4c1f-b3e6-19482cccde8d", "name": "p1rlv16424", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4bac0a18-2477-438a-94a0-812507fc8fcd"}}}}, {"uuid": "0a20861b-7864-4182-b71d-404098b80998", "name": "", "x": 38.65497278403905, "y": -122.46523250990784, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "96dcd934-01a0-4719-89bc-a18430edf179", "name": "p1rdt7735lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a20861b-7864-4182-b71d-404098b80998"}}}}, {"uuid": "fe1bfd41-fe22-4cbe-ab09-2fa1f2f47f5a", "name": "", "x": 38.65486042898651, "y": -122.46493056100381, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8e090544-3c8e-4716-9dae-0b311a1017ea", "name": "p1rlv16445", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fe1bfd41-fe22-4cbe-ab09-2fa1f2f47f5a"}}}}, {"uuid": "63c6b927-d3dc-4646-aec2-7061f58953c5", "name": "", "x": 38.653199252282036, "y": -122.46489297492766, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5ed564b5-8d49-4ff7-94c2-b245981472e8", "name": "p1rdt7790lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "63c6b927-d3dc-4646-aec2-7061f58953c5"}}}}, {"uuid": "98406b17-db64-435a-89ca-371b67b5b8e4", "name": "", "x": 38.65291599440307, "y": -122.46539322901351, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "53d578d8-8492-471b-8f66-233e489a3652", "name": "p1rlv16570", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "98406b17-db64-435a-89ca-371b67b5b8e4"}}}}, {"uuid": "38850062-35c5-42c4-8473-53df10d67257", "name": "", "x": 38.62241982511306, "y": -122.43971932407153, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b9dd5bb5-1410-4635-8a85-d23d7c3e55ad", "name": "p1rdt7954lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "38850062-35c5-42c4-8473-53df10d67257"}}}}, {"uuid": "40b7450c-e6b0-4a78-af62-e7c24b136327", "name": "", "x": 38.62265588015955, "y": -122.43879451092451, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7578563f-d4b3-423b-a8f5-3ee91a042d19", "name": "p1rlv16905", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "40b7450c-e6b0-4a78-af62-e7c24b136327"}}}}, {"uuid": "36950be0-4fd3-451a-9fac-8409812f4199", "name": "", "x": 38.622543574694504, "y": -122.43980628940227, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e982887d-97c6-4af5-b536-a15a372b3379", "name": "p1rdm17416", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "36950be0-4fd3-451a-9fac-8409812f4199"}}}}, {"uuid": "f39b6cba-092a-4569-9a47-5b35d3249d8e", "name": "", "x": 38.62287193593768, "y": -122.43874687668992, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4faf40b9-9ade-45b5-ade8-3f1833605cd1", "name": "p1rlv16882", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f39b6cba-092a-4569-9a47-5b35d3249d8e"}}}}, {"uuid": "967a9ca5-e96e-430d-84d9-5cdc3b729f49", "name": "", "x": 38.62281759636039, "y": -122.43998044342054, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3a96167-4b09-49c9-baf7-4fb588ecb002", "name": "p1rdt7973lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "967a9ca5-e96e-430d-84d9-5cdc3b729f49"}}}}, {"uuid": "756b813f-44fd-4a19-ba1d-6f9e311b850f", "name": "", "x": 38.623145420142684, "y": -122.43939954007212, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c2308dc3-d10b-4049-862d-caf3356fa9a7", "name": "p1rlv16912", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "756b813f-44fd-4a19-ba1d-6f9e311b850f"}}}}, {"uuid": "edeba34e-bd5b-47af-bada-d48b971f09c9", "name": "", "x": 38.62309085570953, "y": -122.43929657626467, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "11a633b0-2b09-4c66-94d4-d1c24cdd9cf5", "name": "p1rlv16988", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "edeba34e-bd5b-47af-bada-d48b971f09c9"}}}}, {"uuid": "29f78aa6-2219-41f0-b8fd-73cfb14343d6", "name": "", "x": 38.622914421161234, "y": -122.44009059423414, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "53ed549a-9c24-4bdd-9e40-aee5308d8120", "name": "p1rdm17505", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "29f78aa6-2219-41f0-b8fd-73cfb14343d6"}}}}, {"uuid": "b591bafa-ff50-4f54-a8fb-5aca6caab3c9", "name": "", "x": 38.62313800426249, "y": -122.43973273911827, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4c570ef7-c483-4c1e-b0fd-8712e8e9a7cd", "name": "p1rlv16904", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b591bafa-ff50-4f54-a8fb-5aca6caab3c9"}}}}, {"uuid": "b8e4d113-43ab-498e-ba02-2cda8df4a829", "name": "", "x": 38.618288153419634, "y": -122.43508780454101, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cb63be48-94ec-4c9f-9991-77892e14171b", "name": "p1rdt7983lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b8e4d113-43ab-498e-ba02-2cda8df4a829"}}}}, {"uuid": "786f1d10-0412-4963-9e25-0d1e156451c2", "name": "", "x": 38.6178110723834, "y": -122.43578826842699, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "07e01053-37f3-4b9f-a9f1-d51bccd29803", "name": "p1rlv16919", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "786f1d10-0412-4963-9e25-0d1e156451c2"}}}}, {"uuid": "ecbeb3c5-deaf-40f8-b0f7-c5efa49d8122", "name": "", "x": 38.617981016890134, "y": -122.43552274050253, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dfa28657-cd8e-4700-a189-83e021f77bee", "name": "p1rlv17033", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ecbeb3c5-deaf-40f8-b0f7-c5efa49d8122"}}}}, {"uuid": "9b9c7472-9dea-4ebe-8b54-92c0d3484b0a", "name": "", "x": 38.60009989462982, "y": -122.45165246954828, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "415fe6e9-953e-40f6-8ae8-43834e4e6ce4", "name": "p1rdt7986lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9b9c7472-9dea-4ebe-8b54-92c0d3484b0a"}}}}, {"uuid": "ae9eb3b3-537f-40c2-943f-3469e0711386", "name": "", "x": 38.60019584777296, "y": -122.45157886471317, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ce315d98-1556-429b-aebb-0c868892396a", "name": "p1rlv16922", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ae9eb3b3-537f-40c2-943f-3469e0711386"}}}}, {"uuid": "e1274621-2f83-4c64-9c96-f50c8d474a6c", "name": "", "x": 38.5999461596242, "y": -122.45214347781915, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7dff1455-5154-429f-a33f-044d8501281d", "name": "p1rlv16957", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e1274621-2f83-4c64-9c96-f50c8d474a6c"}}}}, {"uuid": "85b83e09-ec12-486f-ad2e-0555a1ba557f", "name": "", "x": 38.60009505177635, "y": -122.45122362894173, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "19130741-0fe1-4a12-8a55-96355609bccb", "name": "p1rlv17063", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "85b83e09-ec12-486f-ad2e-0555a1ba557f"}}}}, {"uuid": "6897a9e4-802b-4dc9-a6ca-c8eca130dd9c", "name": "", "x": 38.61708288860949, "y": -122.43744053773406, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "94f12107-697c-4278-95e0-32b6eb49fdb3", "name": "p1rdt7988lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6897a9e4-802b-4dc9-a6ca-c8eca130dd9c"}}}}, {"uuid": "999335b2-ae36-40cb-9fd3-b2738191bb3d", "name": "", "x": 38.61700772395571, "y": -122.43739120644287, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ba1d053-4462-4eb4-aca6-5ede38aa283c", "name": "p1rlv16926", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "999335b2-ae36-40cb-9fd3-b2738191bb3d"}}}}, {"uuid": "52cf2f27-de63-46c8-92e2-0e220ca503d5", "name": "", "x": 38.6171461348718, "y": -122.43747450374505, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5439f343-8176-4d92-99d4-bb9209817f6b", "name": "p1rlv17106", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "52cf2f27-de63-46c8-92e2-0e220ca503d5"}}}}, {"uuid": "f1373852-4d12-4fab-86ca-a37b50a04f22", "name": "", "x": 38.62030446603571, "y": -122.4376486590166, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f5b22c57-7912-4e9f-9b06-6a8ff706a58d", "name": "p1rdt8012lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f1373852-4d12-4fab-86ca-a37b50a04f22"}}}}, {"uuid": "0a779003-8296-47e1-b30a-ece8f8025987", "name": "", "x": 38.619635701851216, "y": -122.43854235774572, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "57e8aa34-3967-4f22-a978-cb513c49c153", "name": "p1rlv16992", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a779003-8296-47e1-b30a-ece8f8025987"}}}}, {"uuid": "3b30dab7-8ea2-4d20-afae-2bb1a6efded1", "name": "", "x": 38.61994945069005, "y": -122.43819529796752, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bd48a076-5f8f-426a-b294-183700d1a123", "name": "p1rlv17069", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3b30dab7-8ea2-4d20-afae-2bb1a6efded1"}}}}, {"uuid": "a2a5e5d8-edf7-451c-b710-08f3ebe5620f", "name": "", "x": 38.60637102325893, "y": -122.45140950104778, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a6c5d7ff-cfcd-4b30-98db-eb44a95d6841", "name": "p1rdt8015lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a2a5e5d8-edf7-451c-b710-08f3ebe5620f"}}}}, {"uuid": "6a96ff2a-cd9b-4d06-8c13-ef04fa2bd59d", "name": "", "x": 38.60632273742159, "y": -122.45132550281518, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f23214ee-3032-4403-9084-8117e89cb1cf", "name": "p1rlv17001", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a96ff2a-cd9b-4d06-8c13-ef04fa2bd59d"}}}}, {"uuid": "d18a87e9-8f1c-4a7a-bf3f-195c6b8f25a2", "name": "", "x": 38.60636860276844, "y": -122.45149742797311, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "213e6d98-ad57-4034-b2d0-4b096554cac2", "name": "p1rlv17028", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d18a87e9-8f1c-4a7a-bf3f-195c6b8f25a2"}}}}, {"uuid": "74928a51-a3eb-4475-a089-b643f8e3cddd", "name": "", "x": 38.620582059906845, "y": -122.43797607749299, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "972fe574-f88e-4a8d-8845-d5baa2f378a7", "name": "p1rdt8034lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "74928a51-a3eb-4475-a089-b643f8e3cddd"}}}}, {"uuid": "57807a14-3fcd-490d-a976-2296f5ca4a86", "name": "", "x": 38.620214408134636, "y": -122.43835802321873, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "92aff718-b70f-4ea4-b38b-fae69a470c58", "name": "p1rlv17059", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "57807a14-3fcd-490d-a976-2296f5ca4a86"}}}}, {"uuid": "652294b0-563d-4bfd-b434-dcdbf4f1f2c8", "name": "", "x": 38.59894295708058, "y": -122.46830816449578, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9951633b-4311-4ca2-9316-3801be13fe97", "name": "p1rdt8149lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "652294b0-563d-4bfd-b434-dcdbf4f1f2c8"}}}}, {"uuid": "24cd4106-fd1e-4e94-a044-53af52c6d2ca", "name": "", "x": 38.598821308346544, "y": -122.46812594296912, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d9778ed5-f0c0-44de-b0d4-60659a54fa3b", "name": "p1rlv17319", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "24cd4106-fd1e-4e94-a044-53af52c6d2ca"}}}}, {"uuid": "f10ee951-5720-4c53-bd7f-7ff21679759b", "name": "", "x": 38.598867566369016, "y": -122.46838972837861, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4970bc03-bc57-4a42-b0cb-66002af1709e", "name": "p1rlv17334", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f10ee951-5720-4c53-bd7f-7ff21679759b"}}}}, {"uuid": "be323039-e11a-4d50-ae15-10c1ce1c9187", "name": "", "x": 38.59870152218132, "y": -122.4669250043453, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6cd1ae47-6aaa-4b57-ba44-1e74f6ea54b7", "name": "p1rdt8150lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be323039-e11a-4d50-ae15-10c1ce1c9187"}}}}, {"uuid": "2876bba6-9299-413f-b90c-6f858847f3c5", "name": "", "x": 38.59827116190417, "y": -122.46741050201447, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "79991b02-c0f1-4b9b-a55e-e9b4ff7c17d9", "name": "p1rlv17320", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2876bba6-9299-413f-b90c-6f858847f3c5"}}}}, {"uuid": "7dbc0a5b-096f-467d-8654-2443b4048e03", "name": "", "x": 38.599111058885946, "y": -122.46644716803104, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6ceb2d77-2da7-44df-9f28-69ed35835775", "name": "p1rlv17326", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7dbc0a5b-096f-467d-8654-2443b4048e03"}}}}, {"uuid": "7e3afdac-e798-4f5f-a6bf-8b16a3ecc303", "name": "", "x": 38.599727655355764, "y": -122.4681198081272, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75a8deb5-b46b-4d4c-876c-b44b2258a6fa", "name": "p1rdt8151lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7e3afdac-e798-4f5f-a6bf-8b16a3ecc303"}}}}, {"uuid": "65e01278-ee98-422b-a1ee-5e7071567570", "name": "", "x": 38.599692587118206, "y": -122.46815246602429, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "00ed745d-78ae-47f6-b6ef-4edf8794ca6a", "name": "p1rdt8151lv-p1rlv17321x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65e01278-ee98-422b-a1ee-5e7071567570"}}}}, {"uuid": "e413bf90-133e-4824-8fae-b54739e28318", "name": "", "x": 38.599654808831716, "y": -122.46817784954497, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "94ce8ee2-6f57-407a-93e9-c06f79d66262", "name": "p1rdt8151lv-p1rlv17321xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e413bf90-133e-4824-8fae-b54739e28318"}}}}, {"uuid": "b16cfa2e-327a-4cd1-af35-0b3f8d8e6192", "name": "", "x": 38.59971750379885, "y": -122.46702835755418, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ce41ac7c-06c5-435a-957d-c9dda83c1893", "name": "p1rlv17321", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b16cfa2e-327a-4cd1-af35-0b3f8d8e6192"}}}}, {"uuid": "51b25475-572c-43ef-b08b-4bc4bc2e516d", "name": "", "x": 38.599821698957996, "y": -122.46814152774704, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "abb24254-be79-45d4-8d9b-246b3e89c00f", "name": "p1rlv20188", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "51b25475-572c-43ef-b08b-4bc4bc2e516d"}}}}, {"uuid": "73645010-aad0-4777-9ab9-4d588ae8adc5", "name": "", "x": 38.59932106464093, "y": -122.4698880830305, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7a542ca5-b24e-44dc-8b68-c00aa024afad", "name": "p1rdt8153lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "73645010-aad0-4777-9ab9-4d588ae8adc5"}}}}, {"uuid": "bcc547e6-c25f-4156-a23e-52ef6e3c66a3", "name": "", "x": 38.59930726241313, "y": -122.4699390974389, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9b96606c-9336-4299-be8d-295c84943a9d", "name": "p1rlv17325", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bcc547e6-c25f-4156-a23e-52ef6e3c66a3"}}}}, {"uuid": "12a4a536-86b1-4eea-a894-3802183a70e7", "name": "", "x": 38.5995160751222, "y": -122.47116135904078, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32fefbef-e10b-4758-8c2e-ccafad49aa5d", "name": "p1rdt8154lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "12a4a536-86b1-4eea-a894-3802183a70e7"}}}}, {"uuid": "bc792def-db51-4a96-a8b0-19f05e3269c4", "name": "", "x": 38.59950227233904, "y": -122.4712123733502, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a43eb022-d5e0-47c8-aa36-6ca0d212ab07", "name": "p1rlv17328", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bc792def-db51-4a96-a8b0-19f05e3269c4"}}}}, {"uuid": "c3d91646-a40b-40ca-80bb-61f7e6f26a01", "name": "", "x": 38.598945724578684, "y": -122.46814818814434, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "51812cd8-eec8-4862-8413-d25a7e9862dc", "name": "p1rdt8155lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c3d91646-a40b-40ca-80bb-61f7e6f26a01"}}}}, {"uuid": "fc85bc7f-eb62-491d-a8dd-e16c26eaa370", "name": "", "x": 38.59855694337255, "y": -122.46746183798086, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "61ef37c1-f14f-4b79-a428-d51a6f0d076a", "name": "p1rlv17329", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fc85bc7f-eb62-491d-a8dd-e16c26eaa370"}}}}, {"uuid": "85a37c02-3c14-40bb-9d81-588a0997012f", "name": "", "x": 38.59929944436906, "y": -122.4682372527046, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cb2a5041-28a1-4fda-905b-caf53ebbefe3", "name": "p1rdm17903", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "85a37c02-3c14-40bb-9d81-588a0997012f"}}}}, {"uuid": "600dd5af-b1ef-4e7d-9206-2af3992c0b0d", "name": "", "x": 38.599299287824266, "y": -122.46820280233233, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48ad7bb0-8dd7-457a-b77d-6db2071c2fe7", "name": "p1rlv17330", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "600dd5af-b1ef-4e7d-9206-2af3992c0b0d"}}}}, {"uuid": "c6354fad-0bf0-4b9f-8e5b-9393b20d716a", "name": "", "x": 38.59897593725153, "y": -122.46956906444683, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fa6d4429-8a95-4ebd-9e3a-9867734245bd", "name": "p1rdt8157lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c6354fad-0bf0-4b9f-8e5b-9393b20d716a"}}}}, {"uuid": "bafc48cf-5d8c-4306-98a9-d215091f7b50", "name": "", "x": 38.598949958035, "y": -122.46952646674691, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33b66eb9-3b21-4f92-b19b-6a0eef4134d8", "name": "p1rlv17333", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bafc48cf-5d8c-4306-98a9-d215091f7b50"}}}}, {"uuid": "90af01ca-1950-494d-b325-b227d69c91bf", "name": "", "x": 38.64315249575866, "y": -122.47114976892446, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e1dd4660-3cd0-4709-b1ef-1c598e5e39fb", "name": "p1rdt8159lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "90af01ca-1950-494d-b325-b227d69c91bf"}}}}, {"uuid": "fb4f265f-b768-470b-b88f-c854b51fcff9", "name": "", "x": 38.64322634740489, "y": -122.47091189149079, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a5d0a174-d49d-4c7e-a669-092f6408edf4", "name": "p1rlv20480", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fb4f265f-b768-470b-b88f-c854b51fcff9"}}}}, {"uuid": "e08079d3-edd1-4bc8-b081-44dd5362f947", "name": "", "x": 38.64301980977188, "y": -122.47107428162515, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3484e698-3a4e-4a88-aaa3-1dc88cd9ac89", "name": "p1rdm17907", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e08079d3-edd1-4bc8-b081-44dd5362f947"}}}}, {"uuid": "bda4f4c6-ba52-422b-bb2d-4154135e8feb", "name": "", "x": 38.64306413997204, "y": -122.47091308420728, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0b645969-9136-42a9-b5ac-7d2f1ff71959", "name": "p1rlv17336", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bda4f4c6-ba52-422b-bb2d-4154135e8feb"}}}}, {"uuid": "cea73a9b-9f97-4242-820d-0a18752b434b", "name": "", "x": 38.643206712841376, "y": -122.47055581957126, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7af262b7-285c-4d06-b7ff-2f2a1971055a", "name": "p1rlv20492", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cea73a9b-9f97-4242-820d-0a18752b434b"}}}}, {"uuid": "dcb6e9c3-b78b-427f-835d-56f4c83eb710", "name": "", "x": 38.64331796921429, "y": -122.47124445290501, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6112cc26-bc37-4c72-8ef6-cd88f1296693", "name": "p1rdm17908", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dcb6e9c3-b78b-427f-835d-56f4c83eb710"}}}}, {"uuid": "0b5adf50-29df-4ada-9ca9-a7c149090ecb", "name": "", "x": 38.64340709749659, "y": -122.47102547122093, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8934db59-0c39-4838-9f8c-59a563cd9d54", "name": "p1rlv20455", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0b5adf50-29df-4ada-9ca9-a7c149090ecb"}}}}, {"uuid": "4410ab61-f4d7-4686-b7a5-9283f71a955f", "name": "", "x": 38.647797936596966, "y": -122.46665816549304, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "232fed6b-fe0f-4a44-93e9-e6675b50c39c", "name": "p1rdt8160lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4410ab61-f4d7-4686-b7a5-9283f71a955f"}}}}, {"uuid": "6ba1a4ef-2877-4400-a039-d27b9912e1d2", "name": "", "x": 38.64781228772558, "y": -122.4667089672996, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d5d7049e-9d30-474c-9033-3ad9b4487f7a", "name": "p1rlv17337", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6ba1a4ef-2877-4400-a039-d27b9912e1d2"}}}}, {"uuid": "a8334a25-2ec8-45e1-90a0-56ac56a0edc3", "name": "", "x": 38.644602062665655, "y": -122.47222549352858, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ac7e489e-7249-4702-9ed6-131cad34500f", "name": "p1rdt8161lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8334a25-2ec8-45e1-90a0-56ac56a0edc3"}}}}, {"uuid": "14ba7656-3e7a-48eb-84c9-cff77db459fd", "name": "", "x": 38.644748791082094, "y": -122.47278523601162, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "331389ab-5d04-4648-83b4-3043198c774f", "name": "p1rlv17338", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "14ba7656-3e7a-48eb-84c9-cff77db459fd"}}}}, {"uuid": "0680cc6e-da56-4ac2-b868-8618f91b4a6a", "name": "", "x": 38.617206962751396, "y": -122.42934627658663, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9560197a-21d1-4601-8bcb-213df4844f4a", "name": "p1rdt8346lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0680cc6e-da56-4ac2-b868-8618f91b4a6a"}}}}, {"uuid": "87600d73-a33f-43c6-92ff-0cbccc7eef41", "name": "", "x": 38.61718096900156, "y": -122.4293036828715, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7acb4e7d-cb06-4848-952d-7c68bb34b6db", "name": "p1rlv17702", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "87600d73-a33f-43c6-92ff-0cbccc7eef41"}}}}, {"uuid": "d12a0724-e31b-404e-8bac-0c3f130fa7e6", "name": "", "x": 38.61731941811156, "y": -122.46431093057339, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "408d5d7b-fc71-46bb-8de0-2d4e628c29b6", "name": "p1rdt8405lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d12a0724-e31b-404e-8bac-0c3f130fa7e6"}}}}, {"uuid": "59b1e009-bbd6-4229-8a8f-0ffc8ba2fd39", "name": "", "x": 38.61734493344011, "y": -122.46426786943886, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a52db2ff-b782-40c1-828a-c65f6929b2fc", "name": "p1rlv17781", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59b1e009-bbd6-4229-8a8f-0ffc8ba2fd39"}}}}, {"uuid": "4baa2cfd-b95d-4843-9f15-6446ca83fe8b", "name": "", "x": 38.62043416913732, "y": -122.45626485935486, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3fe0f77-a7c1-48e3-94aa-30b69f20ca65", "name": "p1rdt8408lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4baa2cfd-b95d-4843-9f15-6446ca83fe8b"}}}}, {"uuid": "1eae8901-0307-473a-a766-33150cf5b60b", "name": "", "x": 38.62067425594847, "y": -122.4561786638706, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9c9c1d9f-eeff-454f-b3d0-7e7de837694c", "name": "p1rlv17787", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1eae8901-0307-473a-a766-33150cf5b60b"}}}}, {"uuid": "bab9d82d-9b34-48ac-b25c-565c4824842b", "name": "", "x": 38.62014326917501, "y": -122.45633200676872, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b40fac8c-a99b-4baa-940a-26565ba7d62b", "name": "p1rlv18044", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bab9d82d-9b34-48ac-b25c-565c4824842b"}}}}, {"uuid": "c80213c4-13ed-4f25-a3db-f0e44ee86016", "name": "", "x": 38.62377947083559, "y": -122.45617863919693, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fca92353-c013-4c41-8507-ec8704410834", "name": "p1rdt8414lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c80213c4-13ed-4f25-a3db-f0e44ee86016"}}}}, {"uuid": "3bbdb11f-382f-4722-98b6-18945dc957b4", "name": "", "x": 38.623816236226766, "y": -122.4555001331194, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d9dba02d-086c-4906-9c6f-86532e3384c0", "name": "p1rlv17798", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3bbdb11f-382f-4722-98b6-18945dc957b4"}}}}, {"uuid": "f094ddcf-5d31-4a5f-853f-8314aa17aa7b", "name": "", "x": 38.59895000377746, "y": -122.46337821887984, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cfe35c35-8164-4825-81e3-10a2ece2cb27", "name": "p1rdt8422lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f094ddcf-5d31-4a5f-853f-8314aa17aa7b"}}}}, {"uuid": "0036a891-6aaf-4b34-8cf0-810e4e8d6bf0", "name": "", "x": 38.59842227673629, "y": -122.46362727672292, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3887a879-0783-4703-8a24-32b7e3b4f39d", "name": "p1rlv17810", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0036a891-6aaf-4b34-8cf0-810e4e8d6bf0"}}}}, {"uuid": "b81a4b3e-aeac-4baf-bc74-00bc42937f30", "name": "", "x": 38.59798139328054, "y": -122.46377984508203, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6f7776e4-a81f-48d2-b3c0-d70bfa48164e", "name": "p1rlv17847", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b81a4b3e-aeac-4baf-bc74-00bc42937f30"}}}}, {"uuid": "6e44a3e6-b8a2-4262-8184-2c558056127d", "name": "", "x": 38.598224600790864, "y": -122.46375506824658, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75e55237-b847-4fb7-a141-a0771bd868c6", "name": "p1rlv17876", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6e44a3e6-b8a2-4262-8184-2c558056127d"}}}}, {"uuid": "3e55eaf4-6618-482f-b4e3-c232453615b3", "name": "", "x": 38.59902589482566, "y": -122.46358833294255, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a7421f5c-bf5c-4d01-aa14-ba657f242080", "name": "p1rdm18545", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e55eaf4-6618-482f-b4e3-c232453615b3"}}}}, {"uuid": "e8a52517-868f-4231-8bad-cc741df29cce", "name": "", "x": 38.598360195447086, "y": -122.46384592887894, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2716887e-1701-4a78-805b-96da0781c7f8", "name": "p1rlv17961", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e8a52517-868f-4231-8bad-cc741df29cce"}}}}, {"uuid": "0ddbc6a9-40f9-4e00-a77f-e50a854446b3", "name": "", "x": 38.597552657762314, "y": -122.45740568785139, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cdc5ef2a-c0d0-4702-b6c6-df08af1e8746", "name": "p1rdt8434lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0ddbc6a9-40f9-4e00-a77f-e50a854446b3"}}}}, {"uuid": "c280eb31-f020-492f-8511-02bbf631c40b", "name": "", "x": 38.59741052481255, "y": -122.45723847553955, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0827675c-2467-403d-822e-5f74cd6296c5", "name": "p1rlv17857", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c280eb31-f020-492f-8511-02bbf631c40b"}}}}, {"uuid": "e0797818-9133-4fd4-93f8-5ecdb12592b1", "name": "", "x": 38.59577787216432, "y": -122.45996961185554, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b24c9345-625f-499d-96cf-30b2de5839b6", "name": "p1rdt8436lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e0797818-9133-4fd4-93f8-5ecdb12592b1"}}}}, {"uuid": "6b2266b6-8a5f-4e6d-8b4b-b4d91bf314c5", "name": "", "x": 38.59575188947818, "y": -122.45992701953358, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f44b0293-61e5-4054-b2d7-4a113df92b3c", "name": "p1rlv17877", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6b2266b6-8a5f-4e6d-8b4b-b4d91bf314c5"}}}}, {"uuid": "235a5cab-5833-447d-938d-8458cbfe5858", "name": "", "x": 38.61790022449083, "y": -122.4571375571412, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a38f544-e250-4fc9-942c-946c5cde0a33", "name": "p1rdt8439lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "235a5cab-5833-447d-938d-8458cbfe5858"}}}}, {"uuid": "ae72de9d-225e-480d-9e53-9d298035cd06", "name": "", "x": 38.61807504073576, "y": -122.45730102691826, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3f74f217-4765-406d-9646-d8f46377ef0a", "name": "p1rlv17897", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ae72de9d-225e-480d-9e53-9d298035cd06"}}}}, {"uuid": "d1f565f4-1b19-4624-acab-6843789b0f04", "name": "", "x": 38.597579593964674, "y": -122.45871858209406, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c6460e5c-839d-4f9e-b9d6-b187fddb9ab6", "name": "p1rdm18631", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1f565f4-1b19-4624-acab-6843789b0f04"}}}}, {"uuid": "e30f89b8-4654-434d-a298-685c0c334130", "name": "", "x": 38.59739305808095, "y": -122.45930564328731, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ab733d49-bb36-4631-8824-1967f98f758a", "name": "p1rlv17909", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e30f89b8-4654-434d-a298-685c0c334130"}}}}, {"uuid": "b0e348c6-668d-45f5-89d6-80130a49de58", "name": "", "x": 38.59774507812581, "y": -122.45881317872153, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "049362b4-49de-4e80-921e-ff763aaab2d1", "name": "p1rdt8440lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b0e348c6-668d-45f5-89d6-80130a49de58"}}}}, {"uuid": "6eb673d0-753b-41b4-9d72-6e3b93827970", "name": "", "x": 38.59785985557703, "y": -122.45891169861048, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7633fe6b-a48b-4e7d-90e6-a38b8a861936", "name": "p1rdm18632", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6eb673d0-753b-41b4-9d72-6e3b93827970"}}}}, {"uuid": "7b013b37-85eb-43c0-8866-e81aa9d95460", "name": "", "x": 38.59783092542888, "y": -122.45911464995726, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1ccaf70a-35d8-4f16-b632-e282fe30b5ca", "name": "p1rlv17969", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7b013b37-85eb-43c0-8866-e81aa9d95460"}}}}, {"uuid": "50b1484b-4818-4428-9e9a-3bde30411fd7", "name": "", "x": 38.592426036395636, "y": -122.46351864990689, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "72c8f08a-0ba5-413e-a805-f9436b41ff29", "name": "p1rdt8441lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "50b1484b-4818-4428-9e9a-3bde30411fd7"}}}}, {"uuid": "a04c8189-e692-459c-a5f1-48dde6ab4744", "name": "", "x": 38.59244738401374, "y": -122.46362580620794, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3eb66d3-0271-4842-8893-9a58f64e0279", "name": "p1rlv17912", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a04c8189-e692-459c-a5f1-48dde6ab4744"}}}}, {"uuid": "8a776ad0-780d-4247-ade1-f5cf9ea31a4b", "name": "", "x": 38.597607065823205, "y": -122.46357324186411, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6b5ae28a-95f8-4023-aa23-36809fe96b10", "name": "p1rdt8442lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8a776ad0-780d-4247-ade1-f5cf9ea31a4b"}}}}, {"uuid": "b197b384-d376-4d94-876a-0a809b11da97", "name": "", "x": 38.597593266344134, "y": -122.46362425623258, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2812bbb1-0bb0-499f-a394-0995784bb7bc", "name": "p1rlv17926", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b197b384-d376-4d94-876a-0a809b11da97"}}}}, {"uuid": "867451dd-75d8-47b5-bd21-ccfa0b329ea5", "name": "", "x": 38.59572176348798, "y": -122.45708645620138, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "978920e8-edf9-4bee-85f9-45f4081ed0ca", "name": "p1rdt8444lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "867451dd-75d8-47b5-bd21-ccfa0b329ea5"}}}}, {"uuid": "105845cf-c40d-4173-81fd-b74861397ce6", "name": "", "x": 38.59568814197167, "y": -122.45699881396531, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "215a5974-e23b-46f0-bde9-f5ad16fdfaf8", "name": "p1rlv17960", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "105845cf-c40d-4173-81fd-b74861397ce6"}}}}, {"uuid": "10f191de-e023-4808-85f5-012176f1336e", "name": "", "x": 38.595797079946, "y": -122.45717024246757, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "86917829-123c-4fda-9809-dc61430a9fef", "name": "p1rlv18071", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10f191de-e023-4808-85f5-012176f1336e"}}}}, {"uuid": "e52bb183-08e0-4285-8429-5d7606c19fe0", "name": "", "x": 38.61751627823996, "y": -122.46078567224485, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7e0923da-550b-479f-b3d8-3e0320db6701", "name": "p1rdt8445lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e52bb183-08e0-4285-8429-5d7606c19fe0"}}}}, {"uuid": "a8649d36-5197-4a25-b6b5-550f77429a73", "name": "", "x": 38.61713929235215, "y": -122.46152369067127, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ec99daac-e0be-4ea1-ba4f-185d4943396d", "name": "p1rlv17962", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8649d36-5197-4a25-b6b5-550f77429a73"}}}}, {"uuid": "664da3a5-5133-402f-8d86-f3c67ca71d77", "name": "", "x": 38.62155491914008, "y": -122.45674368662482, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5dbc3459-6a17-4075-899a-6aab16fb3ab7", "name": "p1rdt8447lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "664da3a5-5133-402f-8d86-f3c67ca71d77"}}}}, {"uuid": "98a16178-ae9b-49b9-9dba-5f7325d4f142", "name": "", "x": 38.6215289352912, "y": -122.45670108034808, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0771ebfa-5eaf-4ae8-94f1-86de7a656f58", "name": "p1rlv17987", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "98a16178-ae9b-49b9-9dba-5f7325d4f142"}}}}, {"uuid": "605fd3a1-c920-45b2-ad64-ca60322bc1c0", "name": "", "x": 38.59745455680166, "y": -122.45591485249561, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8b4216c8-9e99-446c-ad09-5a09f046dd59", "name": "p1rdt8450lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "605fd3a1-c920-45b2-ad64-ca60322bc1c0"}}}}, {"uuid": "f8e8c7c1-26b6-495f-9e34-86907f86c0ad", "name": "", "x": 38.597480069191974, "y": -122.45587180037909, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4aeda1c7-41be-43c8-82e5-d7a347db86a8", "name": "p1rlv18053", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f8e8c7c1-26b6-495f-9e34-86907f86c0ad"}}}}, {"uuid": "ac621d29-9618-4700-9b16-28e6618b6676", "name": "", "x": 38.623331409033426, "y": -122.45649925442898, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d094b779-ebcc-4837-9ccb-31808e2a544b", "name": "p1rdt8456lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ac621d29-9618-4700-9b16-28e6618b6676"}}}}, {"uuid": "722dda28-849d-4e17-a584-550e06ef2a68", "name": "", "x": 38.62321497484187, "y": -122.45604459936547, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c4863d28-4ee2-479d-accb-60b54f472fe7", "name": "p1rlv18100", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "722dda28-849d-4e17-a584-550e06ef2a68"}}}}, {"uuid": "dc23a352-01e5-4e67-9210-bb6fbafba6c4", "name": "", "x": 38.62104504107823, "y": -122.4556217772947, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e597d8da-e876-44a5-a109-1ce84527c557", "name": "p1rdt8458lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dc23a352-01e5-4e67-9210-bb6fbafba6c4"}}}}, {"uuid": "f36410e9-465d-44f3-8ab5-6e0fd2624084", "name": "", "x": 38.62101905682373, "y": -122.45557917172717, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "115a848f-f6f3-48f0-9f33-5a9103f1a892", "name": "p1rlv18129", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f36410e9-465d-44f3-8ab5-6e0fd2624084"}}}}, {"uuid": "804f0048-b140-4280-ba5b-87306c6feacc", "name": "", "x": 38.6478890270985, "y": -122.44178196559784, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "edb15d92-f98a-4fa2-8129-ad8a39e0dc0c", "name": "p1rdt8470lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "804f0048-b140-4280-ba5b-87306c6feacc"}}}}, {"uuid": "4ba6adc1-6162-4155-a2bd-22b86bf1188e", "name": "", "x": 38.6478781196749, "y": -122.4418348710007, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "431692e5-2917-41ea-aafc-96be180b7e27", "name": "p1rlv18166", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ba6adc1-6162-4155-a2bd-22b86bf1188e"}}}}, {"uuid": "b73e98fa-cf90-4060-8e49-9e9faf47c7fb", "name": "", "x": 38.59296538348102, "y": -122.52138816471086, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a84e1424-7faf-4077-9461-b39460f10ef0", "name": "p1rdt8490lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b73e98fa-cf90-4060-8e49-9e9faf47c7fb"}}}}, {"uuid": "ed117aae-82ac-4c66-942a-b71b10ab7463", "name": "", "x": 38.59301371324328, "y": -122.5214951600568, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1c3e08a8-ea88-423d-b361-69509f7ab8fa", "name": "p1rlv18192", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ed117aae-82ac-4c66-942a-b71b10ab7463"}}}}, {"uuid": "5ebb3cfc-a5b0-49a9-a24f-877580473c4b", "name": "", "x": 38.59294983327106, "y": -122.521300375614, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5a7cb078-af6c-4cd5-9aca-48f515f6e711", "name": "p1rlv18198", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ebb3cfc-a5b0-49a9-a24f-877580473c4b"}}}}, {"uuid": "de057e16-abb7-41f6-af51-aebbadc2b25b", "name": "", "x": 38.59325808671421, "y": -122.5203178073169, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "127e4cc7-6413-4482-9ec3-40f8bde02d0c", "name": "p1rdt8492lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "de057e16-abb7-41f6-af51-aebbadc2b25b"}}}}, {"uuid": "ef8d5eb6-940c-46a1-831a-9669016160a2", "name": "", "x": 38.59327241449537, "y": -122.5203685817209, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c5e240e8-b27d-4181-a7ee-a004d3f5c58a", "name": "p1rlv18197", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef8d5eb6-940c-46a1-831a-9669016160a2"}}}}, {"uuid": "a61ec7ca-3ace-4736-9144-904c04e0c148", "name": "", "x": 38.60984174522787, "y": -122.47657385883775, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "95a1a7c7-6055-47c9-a742-c1b81f6c7478", "name": "p1rdt8802lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a61ec7ca-3ace-4736-9144-904c04e0c148"}}}}, {"uuid": "a6e85fe6-c716-4a0f-a8c2-0f24fd3a2386", "name": "", "x": 38.609856091968865, "y": -122.47662463597939, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9178fdee-311f-40f5-bdd6-9b474a05247e", "name": "p1rlv18960", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a6e85fe6-c716-4a0f-a8c2-0f24fd3a2386"}}}}, {"uuid": "2f141231-7a01-4055-8435-d27aaab6e5a0", "name": "", "x": 38.60811019336638, "y": -122.4764535430088, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "715c92fa-2470-4869-8d5f-0b4f3f8360d4", "name": "p1rdt8805lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2f141231-7a01-4055-8435-d27aaab6e5a0"}}}}, {"uuid": "8dee19e0-8f93-421c-89dc-21a73c4b7405", "name": "", "x": 38.60841504125986, "y": -122.4772548473748, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eef4f0cf-6e51-45e1-8b6e-84171f7cbef6", "name": "p1rlv18967", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8dee19e0-8f93-421c-89dc-21a73c4b7405"}}}}, {"uuid": "44c9f757-2bb1-4fa1-b546-bd34b4b7f2f9", "name": "", "x": 38.581410942364535, "y": -122.50908841868979, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f6ff626c-d2fc-4b97-9013-4fd544d946a2", "name": "p1rdt8898lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "44c9f757-2bb1-4fa1-b546-bd34b4b7f2f9"}}}}, {"uuid": "57fd1592-5243-4363-8282-086d2487b045", "name": "", "x": 38.58102797028686, "y": -122.50847493360112, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2cf28b5d-d8d4-4883-a396-2d1ad9b70564", "name": "p1rlv19157", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "57fd1592-5243-4363-8282-086d2487b045"}}}}, {"uuid": "f3f75cf1-080c-47d4-977e-453e2b885282", "name": "", "x": 38.58165154784808, "y": -122.50878549370569, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "09d59048-6e1b-4f7f-b161-81163809eb25", "name": "p1rdm19752", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f3f75cf1-080c-47d4-977e-453e2b885282"}}}}, {"uuid": "e8ccc470-71ba-4c98-aee7-701cc49838f9", "name": "", "x": 38.581235479806075, "y": -122.50853092416536, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "67a4600d-65c3-40d7-ad28-e8e37ff77dcb", "name": "p1rlv19149", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e8ccc470-71ba-4c98-aee7-701cc49838f9"}}}}, {"uuid": "b56887ea-0407-49d2-a1d7-9cbc77058ca0", "name": "", "x": 38.581243768243056, "y": -122.5083586529402, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c7c1d210-ee87-46c5-b408-ad221cbeed04", "name": "p1rlv19160", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b56887ea-0407-49d2-a1d7-9cbc77058ca0"}}}}, {"uuid": "240e4997-1186-4c77-b45b-065a2ebd972c", "name": "", "x": 38.58115574730252, "y": -122.50928817819602, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a7664d29-bbc0-4465-a00a-82af048b86e5", "name": "p1rdm19755", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "240e4997-1186-4c77-b45b-065a2ebd972c"}}}}, {"uuid": "2d04d1e5-eafb-4f34-b561-44619bce9aa4", "name": "", "x": 38.58064928716368, "y": -122.50843159103809, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "994f6392-f4e5-4ff8-9eeb-5849cd035912", "name": "p1rlv19166", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2d04d1e5-eafb-4f34-b561-44619bce9aa4"}}}}, {"uuid": "e8c464bc-8647-472f-ae74-067475e1724b", "name": "", "x": 38.58121826088946, "y": -122.50725268309377, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d53c0a2-78cc-4988-85a4-884ef039f5fa", "name": "p1rdt8901lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e8c464bc-8647-472f-ae74-067475e1724b"}}}}, {"uuid": "11091ed9-9278-418b-a4b8-3759b0797ce7", "name": "", "x": 38.58123620687723, "y": -122.50802972585609, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16df6b90-d049-4160-b148-b888e03acb82", "name": "p1rlv19161", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "11091ed9-9278-418b-a4b8-3759b0797ce7"}}}}, {"uuid": "064e0b49-6ead-4a53-af44-38565a7e6781", "name": "", "x": 38.65991234943945, "y": -122.43854233081237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e111e213-bcbe-42c4-b6ab-2c734ff5341c", "name": "p1rdt8904lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "064e0b49-6ead-4a53-af44-38565a7e6781"}}}}, {"uuid": "40047848-7a14-4001-aecf-88ae0011c629", "name": "", "x": 38.660223463841156, "y": -122.43823709517063, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1f8c76ca-40ea-4f7d-8042-66edd484f065", "name": "p1rlv19168", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "40047848-7a14-4001-aecf-88ae0011c629"}}}}, {"uuid": "f8047d0f-fd7f-4cd1-a199-62ef50463692", "name": "", "x": 38.659990269866015, "y": -122.43846878718209, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e0fc7d43-4f82-4100-99bf-6e30e03e95ce", "name": "p1rlv19174", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f8047d0f-fd7f-4cd1-a199-62ef50463692"}}}}, {"uuid": "184974a9-5002-4bab-bace-c579e696241d", "name": "", "x": 38.659792348994905, "y": -122.43853929357995, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8b9386f2-376d-4439-a9a4-3eefc238dafe", "name": "p1rdm19776", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "184974a9-5002-4bab-bace-c579e696241d"}}}}, {"uuid": "97d3a98b-859b-4c49-9814-8854ec2c9ea8", "name": "", "x": 38.659815187445474, "y": -122.43766561018224, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "50750ddb-80db-4d5f-bc62-4bbfc600a7ef", "name": "p1rlv19184", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "97d3a98b-859b-4c49-9814-8854ec2c9ea8"}}}}, {"uuid": "6760425d-5a9c-4a69-a620-335a6a50dd5a", "name": "", "x": 38.66094193321756, "y": -122.4420778873007, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be2777cc-f3fd-491f-a10b-4ed381cb948d", "name": "p1rdt8905lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6760425d-5a9c-4a69-a620-335a6a50dd5a"}}}}, {"uuid": "e4fb0dbb-9f87-44eb-8fc2-c6fa5b3b190c", "name": "", "x": 38.66079928545388, "y": -122.4418071207425, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be4e8183-9148-477e-aa1b-ff31a5324273", "name": "p1rlv19169", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e4fb0dbb-9f87-44eb-8fc2-c6fa5b3b190c"}}}}, {"uuid": "cdebdf2f-ce8a-4206-9a08-febb53cf2595", "name": "", "x": 38.66134282316126, "y": -122.44240057565185, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fffe26f7-c4cc-420e-ab17-754cb0d9e659", "name": "p1rlv19171", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cdebdf2f-ce8a-4206-9a08-febb53cf2595"}}}}, {"uuid": "a3f6aa7b-1b7e-4b4c-99f6-ba8b0c163e86", "name": "", "x": 38.661324142709425, "y": -122.44226279573506, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "21fec301-b67c-4042-a074-caf406c7f0b5", "name": "p1rlv19173", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a3f6aa7b-1b7e-4b4c-99f6-ba8b0c163e86"}}}}, {"uuid": "e1a509d5-5978-458c-b5a3-4a6ad7aa48bb", "name": "", "x": 38.660891099685436, "y": -122.44216271154556, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "47e24942-486d-46f1-a40f-0da5c93c013a", "name": "p1rlv19188", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e1a509d5-5978-458c-b5a3-4a6ad7aa48bb"}}}}, {"uuid": "8daf8c62-fb93-452e-a50f-f20fd4575028", "name": "", "x": 38.660438772467124, "y": -122.44179842559906, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d7daa1d3-6249-447d-a260-65de5ec0a470", "name": "p1rlv19194", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8daf8c62-fb93-452e-a50f-f20fd4575028"}}}}, {"uuid": "f5014d04-b09d-4eb3-ab03-0922624e3ed6", "name": "", "x": 38.65966647434038, "y": -122.44177391418427, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c306f79a-0240-465e-a486-d0f11614fc57", "name": "p1rdt8911lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5014d04-b09d-4eb3-ab03-0922624e3ed6"}}}}, {"uuid": "ef46d329-2e90-4650-bdbe-4d60014873d6", "name": "", "x": 38.659762694003604, "y": -122.44175769963816, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "89bde057-807b-415c-9135-267c6bf43c44", "name": "p1rlv19183", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef46d329-2e90-4650-bdbe-4d60014873d6"}}}}, {"uuid": "f91d9e6c-5898-4087-987a-3ebafb3c94ca", "name": "", "x": 38.659528505871954, "y": -122.44178250448644, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4a8ae6dc-884d-48d8-9995-fe3936ad019c", "name": "p1rlv20296", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f91d9e6c-5898-4087-987a-3ebafb3c94ca"}}}}, {"uuid": "0edbaaa4-6519-455b-9246-8a1c2a9156ca", "name": "", "x": 38.66174426844995, "y": -122.44236029493588, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2fbbca23-6473-4344-ac2e-cc97078b3d8d", "name": "p1rdt8915lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0edbaaa4-6519-455b-9246-8a1c2a9156ca"}}}}, {"uuid": "6b82329d-8f91-4a11-af20-f5eea8feb9c7", "name": "", "x": 38.66176977524987, "y": -122.44231719933447, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5fecc64a-4783-4ecb-a0d0-7e60d1cf6184", "name": "p1rlv19189", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6b82329d-8f91-4a11-af20-f5eea8feb9c7"}}}}, {"uuid": "9b3f7497-3003-404d-b677-bcdb323c6ab4", "name": "", "x": 38.66022824513094, "y": -122.4403032002883, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d268e33-708d-4bae-8348-cad27fd0d81a", "name": "p1rdt8916lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9b3f7497-3003-404d-b677-bcdb323c6ab4"}}}}, {"uuid": "04b52ef4-71da-4abc-bfca-23d50fefdad0", "name": "", "x": 38.66024260770121, "y": -122.44035400544816, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4aee02d4-8663-455b-a197-55b6b1470895", "name": "p1rlv19190", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "04b52ef4-71da-4abc-bfca-23d50fefdad0"}}}}, {"uuid": "3a99f762-bf86-47c2-a9c5-ba32b79116be", "name": "", "x": 38.655203793367576, "y": -122.45620231524185, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6752e8f4-9e37-476d-aec2-4a2fe7c1e2dc", "name": "p1rdt9075lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3a99f762-bf86-47c2-a9c5-ba32b79116be"}}}}, {"uuid": "2f6f79fa-c192-4f73-8fe9-34244be1e20a", "name": "", "x": 38.65518999754597, "y": -122.45625337194336, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33dcb037-4cc8-480f-aac4-bc95e54e165e", "name": "p1rlv19667", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2f6f79fa-c192-4f73-8fe9-34244be1e20a"}}}}, {"uuid": "18e29a87-cfae-409d-a4d0-59cdfda79164", "name": "", "x": 38.659371136386014, "y": -122.45366040420096, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bdd64386-e256-47f8-8cef-1c933f993a29", "name": "p1rdt9076lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "18e29a87-cfae-409d-a4d0-59cdfda79164"}}}}, {"uuid": "510bb7b0-5542-41e1-85d9-ab5f40613641", "name": "", "x": 38.65966620569122, "y": -122.45316394323339, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "14b1ab4e-b22d-4a98-8131-fc72c923c735", "name": "p1rlv19698", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "510bb7b0-5542-41e1-85d9-ab5f40613641"}}}}, {"uuid": "12fed0c5-f799-4023-b80f-43c58a88eefd", "name": "", "x": 38.65923252263959, "y": -122.45353105574254, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fd00c91a-01a8-4aad-b740-b06a654d631b", "name": "p1rdm20204", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "12fed0c5-f799-4023-b80f-43c58a88eefd"}}}}, {"uuid": "6ba53ded-0201-4663-a8a2-5703783675ba", "name": "", "x": 38.65913430903858, "y": -122.45372718962375, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6427f66-2e22-40bb-83f1-2a8b1be9191a", "name": "p1rlv19668", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6ba53ded-0201-4663-a8a2-5703783675ba"}}}}, {"uuid": "7a201e5f-5a2b-4c99-866d-0b8445ce2f1e", "name": "", "x": 38.659402236788104, "y": -122.45320795008209, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48654a82-ac11-4542-94ec-8f731138e1a8", "name": "p1rlv19699", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7a201e5f-5a2b-4c99-866d-0b8445ce2f1e"}}}}, {"uuid": "3219c596-244a-4592-ac08-1498542b882a", "name": "", "x": 38.65946805558687, "y": -122.45379361501921, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ce8f50bb-90fb-49b8-8a16-1bbbb6a0c82c", "name": "p1rdm20205", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3219c596-244a-4592-ac08-1498542b882a"}}}}, {"uuid": "8c0543e4-bfd1-4ea1-abd8-9f20075a02f4", "name": "", "x": 38.65960231517979, "y": -122.45359720642892, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "47f5777d-2c8d-48c2-bf28-386f3f3dbac4", "name": "p1rlv19686", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8c0543e4-bfd1-4ea1-abd8-9f20075a02f4"}}}}, {"uuid": "61eb89b7-5c68-4fe6-a2cf-65b8a9334552", "name": "", "x": 38.652242872397366, "y": -122.46144885825713, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6b83eaaa-a092-42ca-a746-db4d9658d62b", "name": "p1rdt9077lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "61eb89b7-5c68-4fe6-a2cf-65b8a9334552"}}}}, {"uuid": "d2c378d1-16dd-475a-96e9-e684db274429", "name": "", "x": 38.65239205276167, "y": -122.4611909367415, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "96d3079a-02f1-4c89-ad75-fd0a438c9cf4", "name": "p1rlv19669", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d2c378d1-16dd-475a-96e9-e684db274429"}}}}, {"uuid": "955a59ba-ed77-4cb8-ba64-6835fb9101a6", "name": "", "x": 38.65223106297542, "y": -122.46145646522658, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0031ab1b-d82d-40a5-b41e-bc6f6cb53069", "name": "p1rlv19675", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "955a59ba-ed77-4cb8-ba64-6835fb9101a6"}}}}, {"uuid": "54b6622c-d1f3-4f49-9fe9-b34c2b16e965", "name": "", "x": 38.65203392082483, "y": -122.46169927854602, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35fe21a1-f817-426e-9e42-f1f33876dd7d", "name": "p1rlv19695", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "54b6622c-d1f3-4f49-9fe9-b34c2b16e965"}}}}, {"uuid": "52222e5e-929d-40e5-9033-af986edf0e1c", "name": "", "x": 38.658511634388226, "y": -122.45377906068661, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7f0e4f59-8a46-4abf-9f06-e0383a59a45d", "name": "p1rdt9084lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "52222e5e-929d-40e5-9033-af986edf0e1c"}}}}, {"uuid": "7d2fecb9-f2e2-4813-bc4a-f2dd44b73ae1", "name": "", "x": 38.65890081567661, "y": -122.4539013635132, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "83afc678-d577-4ef1-afa2-8e3f915a158b", "name": "p1rlv19681", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7d2fecb9-f2e2-4813-bc4a-f2dd44b73ae1"}}}}, {"uuid": "87d5d0d0-3503-4fb3-90d4-b7010024e8e1", "name": "", "x": 38.65082653264708, "y": -122.46112619224643, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "565bbfb1-a28f-4db2-be48-cbd58972025a", "name": "p1rdt9085lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "87d5d0d0-3503-4fb3-90d4-b7010024e8e1"}}}}, {"uuid": "024c67e1-26f2-4e2d-a9e1-2363314f620e", "name": "", "x": 38.65123799892708, "y": -122.46107316768796, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "811acd48-b61c-4a42-b76e-f995961c450e", "name": "p1rlv19682", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "024c67e1-26f2-4e2d-a9e1-2363314f620e"}}}}, {"uuid": "e9eeb7a0-71f8-42f2-8fde-92047b07a318", "name": "", "x": 38.650795641302004, "y": -122.46090410093127, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ec27727b-2bb8-4df2-9ddf-46282728c2c0", "name": "p1rdm20223", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e9eeb7a0-71f8-42f2-8fde-92047b07a318"}}}}, {"uuid": "0e0f0e38-cf93-421d-b57f-3480c11f4488", "name": "", "x": 38.65132742554806, "y": -122.46092309986851, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1b5d936f-b3e0-408e-aabd-d3ebb7b869b0", "name": "p1rlv19701", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0e0f0e38-cf93-421d-b57f-3480c11f4488"}}}}, {"uuid": "f408d815-1e53-4979-87cd-e7df5fb7d70f", "name": "", "x": 38.65246361026913, "y": -122.46218753579743, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f8108ac8-2807-4a40-85c2-db21efaadadb", "name": "p1rdt9089lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f408d815-1e53-4979-87cd-e7df5fb7d70f"}}}}, {"uuid": "35ae0831-567f-4d28-ba9e-19a634226d71", "name": "", "x": 38.65247796334516, "y": -122.46223833997352, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "578b5df8-1dd8-41d9-b6dc-db75db5b115e", "name": "p1rlv19689", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "35ae0831-567f-4d28-ba9e-19a634226d71"}}}}, {"uuid": "7fb01aed-5f5d-4a4a-8919-592230ce46fe", "name": "", "x": 38.65140101826137, "y": -122.46336158947928, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6fc84159-09b1-4ca9-9a7a-a4fecab19f83", "name": "p1rdt9090lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7fb01aed-5f5d-4a4a-8919-592230ce46fe"}}}}, {"uuid": "67c1af07-75b2-4ed0-80c3-3d37cc36508d", "name": "", "x": 38.651714420003884, "y": -122.4627704444441, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e2709a70-1a7d-454c-90fd-377e416a0071", "name": "p1rlv19690", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "67c1af07-75b2-4ed0-80c3-3d37cc36508d"}}}}, {"uuid": "b8912d59-aeda-43db-8f27-552d50bb9d26", "name": "", "x": 38.650846513531, "y": -122.46155124895908, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1e93ea18-150d-4d80-bac7-f3e1b87c5b4e", "name": "p1rdt9091lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b8912d59-aeda-43db-8f27-552d50bb9d26"}}}}, {"uuid": "ff33634d-a59f-408c-ac9f-96661327410f", "name": "", "x": 38.65126752046812, "y": -122.4616130767133, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b10b272a-2efb-4e19-9921-d4081fb45778", "name": "p1rlv19692", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ff33634d-a59f-408c-ac9f-96661327410f"}}}}, {"uuid": "43134dcc-0533-4dab-bdbd-171362ac4a36", "name": "", "x": 38.65985495091543, "y": -122.45426942925806, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2f0726b7-3050-4c78-9c06-b9fd0c863ff3", "name": "p1rdt9093lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "43134dcc-0533-4dab-bdbd-171362ac4a36"}}}}, {"uuid": "80050a7c-ddcb-47cd-bd59-7f16d2859412", "name": "", "x": 38.65961615387016, "y": -122.45463151295169, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "37f72c85-61f7-4a42-94b0-6a627195458c", "name": "p1rlv19702", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "80050a7c-ddcb-47cd-bd59-7f16d2859412"}}}}, {"uuid": "f4631a44-4de8-418b-94ae-9e7331f02e3b", "name": "", "x": 38.629339299867084, "y": -122.45270506395599, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1c01a9b2-b002-4279-905e-950452f64f32", "name": "p1rdt9264lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f4631a44-4de8-418b-94ae-9e7331f02e3b"}}}}, {"uuid": "27ed1f16-03eb-42ce-8702-a73fa474132f", "name": "", "x": 38.629416853696135, "y": -122.45255114958653, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aaea76fa-797e-46c5-a70f-a973977db841", "name": "p1rlv20064", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "27ed1f16-03eb-42ce-8702-a73fa474132f"}}}}, {"uuid": "881403a8-f760-42b5-8e71-49adf089ec98", "name": "", "x": 38.629219943787845, "y": -122.4528398621658, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ea48ffa1-bdb3-4c15-96c9-ff7d7f34824f", "name": "p1rlv20065", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "881403a8-f760-42b5-8e71-49adf089ec98"}}}}, {"uuid": "b4544aa4-b735-4c64-84e5-139bf0f516a2", "name": "", "x": 38.62682787398021, "y": -122.443538396124, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "77d62813-61d3-4afd-9f21-869e2ea23e17", "name": "p1rdt9265lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b4544aa4-b735-4c64-84e5-139bf0f516a2"}}}}, {"uuid": "d260b95e-211c-4042-a884-17ace9831ea6", "name": "", "x": 38.626801885358226, "y": -122.44349579157367, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f450eeb4-3d87-4ae5-a6d6-958d7efd2712", "name": "p1rlv20066", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d260b95e-211c-4042-a884-17ace9831ea6"}}}}, {"uuid": "88a974e9-a865-4c00-8ffc-1e39aa989a25", "name": "", "x": 38.63354009061449, "y": -122.4470022329432, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "78278589-be2d-4d99-9c03-92c221348917", "name": "p1rdt9266lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "88a974e9-a865-4c00-8ffc-1e39aa989a25"}}}}, {"uuid": "0c7edbb5-8c60-4dd4-8097-98444bf41092", "name": "", "x": 38.6335544502105, "y": -122.44705302069676, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "66a710fb-26c7-4465-b7ea-43ec107008dc", "name": "p1rlv20067", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0c7edbb5-8c60-4dd4-8097-98444bf41092"}}}}, {"uuid": "59e72f91-e9dd-4f26-9cdd-f72aaafbf0b6", "name": "", "x": 38.57668432917656, "y": -122.5244581272183, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "208f222c-45db-445f-ba0b-a4a195ca68a6", "name": "p1rdt9298lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59e72f91-e9dd-4f26-9cdd-f72aaafbf0b6"}}}}, {"uuid": "af9dc8ee-cee4-460f-9c97-b2613c61e390", "name": "", "x": 38.57703900731173, "y": -122.52455160092381, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ffc82be6-f3f8-4a68-b6e6-da60b137329c", "name": "p1rlv20130", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "af9dc8ee-cee4-460f-9c97-b2613c61e390"}}}}, {"uuid": "4d3a48b7-fd17-4c40-ad5a-1107322e7fa2", "name": "", "x": 38.57648055489435, "y": -122.52532048800711, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "180fad26-0e7d-4e2c-ba17-c8e3315ca278", "name": "p1rdt9302lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d3a48b7-fd17-4c40-ad5a-1107322e7fa2"}}}}, {"uuid": "55752a53-a905-418a-94b6-4741fc94dd93", "name": "", "x": 38.57700673397096, "y": -122.52548171913072, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d635a151-2d13-47e9-8043-a214415a5b5e", "name": "p1rlv20138", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "55752a53-a905-418a-94b6-4741fc94dd93"}}}}, {"uuid": "6be69bf2-e2da-4ffd-8e12-9ecb59720f76", "name": "", "x": 38.57718617464166, "y": -122.52237333536553, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d4940a0e-dcc2-45fb-baa9-aadc84f8e882", "name": "p1rdt9310lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6be69bf2-e2da-4ffd-8e12-9ecb59720f76"}}}}, {"uuid": "ab4905b9-4e99-49bb-a83d-8bfaa642964a", "name": "", "x": 38.576705284221035, "y": -122.5222692278727, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9d615e93-a289-41ec-bda0-3b72bf15677e", "name": "p1rlv20146", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ab4905b9-4e99-49bb-a83d-8bfaa642964a"}}}}, {"uuid": "95a5439a-0a5c-4f7b-ae08-bed7b34b0ecf", "name": "", "x": 38.57637456989155, "y": -122.51922519254137, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b9e0aa7d-9097-4370-8f5e-52a5885da85c", "name": "p1rdt9311lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "95a5439a-0a5c-4f7b-ae08-bed7b34b0ecf"}}}}, {"uuid": "85a764e0-e69e-45dc-8957-3b9ca0ab1fd3", "name": "", "x": 38.576279327246795, "y": -122.51948236126216, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16b2add7-6a6d-4359-ad6f-f60edf435a4c", "name": "p1rlv20147", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "85a764e0-e69e-45dc-8957-3b9ca0ab1fd3"}}}}, {"uuid": "88a233ee-71b3-424d-a3b1-cf5eb54ab2a0", "name": "", "x": 38.57622563406502, "y": -122.51957456046857, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e938635b-e0d2-4e1b-a312-5a8f51e1dd7a", "name": "p1rlv20163", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "88a233ee-71b3-424d-a3b1-cf5eb54ab2a0"}}}}, {"uuid": "252394b9-5e80-462d-b1ad-93684148d1b5", "name": "", "x": 38.57944374835563, "y": -122.52129067940982, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0a21f5ca-51ef-4f81-8229-163182f011cf", "name": "p1rdt9312lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "252394b9-5e80-462d-b1ad-93684148d1b5"}}}}, {"uuid": "f1070023-ce6c-4a46-a28b-44adc0b27a78", "name": "", "x": 38.579207205820964, "y": -122.52143752839837, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a4a0c2f2-f75e-4c9c-b3f7-d8d9ada9cb82", "name": "p1rlv20148", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f1070023-ce6c-4a46-a28b-44adc0b27a78"}}}}, {"uuid": "0c82b69e-699d-4e19-95a1-17d14b7c7c9b", "name": "", "x": 38.57963859321071, "y": -122.52114764756729, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "27dfea92-734e-49d3-b245-dc933df66889", "name": "p1rlv20160", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0c82b69e-699d-4e19-95a1-17d14b7c7c9b"}}}}, {"uuid": "aa912d24-a8bb-448b-a77f-ee94b50f811c", "name": "", "x": 38.57499954420577, "y": -122.51877161682458, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3df13d91-365e-411b-917d-b28df5989280", "name": "p1rdt9314lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aa912d24-a8bb-448b-a77f-ee94b50f811c"}}}}, {"uuid": "03254f1e-f392-4daf-802c-1b58ee985315", "name": "", "x": 38.57488526903181, "y": -122.5194726576567, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3eb214b9-827f-4995-a862-907be02b029d", "name": "p1rlv20473", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "03254f1e-f392-4daf-802c-1b58ee985315"}}}}, {"uuid": "99be95b3-5b0a-4a25-88ec-b2a960507eeb", "name": "", "x": 38.57479824917913, "y": -122.51872307044951, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d5930295-0e44-4498-ae22-7647b72c1fa1", "name": "p1rdm20686", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "99be95b3-5b0a-4a25-88ec-b2a960507eeb"}}}}, {"uuid": "fa40295b-b2bc-4dca-a1a5-18c69a4d7b10", "name": "", "x": 38.574765880638516, "y": -122.5196187229471, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "956f4975-7383-4e0b-9114-d333a6ec4005", "name": "p1rlv20151", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa40295b-b2bc-4dca-a1a5-18c69a4d7b10"}}}}, {"uuid": "842bddbc-e3f4-415c-9892-b5c663d506b7", "name": "", "x": 38.57481830117202, "y": -122.51921657510196, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a7a43aa6-2be8-4320-8089-57d388633c6b", "name": "p1rlv20456", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "842bddbc-e3f4-415c-9892-b5c663d506b7"}}}}, {"uuid": "b7d25399-f31a-4e49-adba-a78ff86c5b8b", "name": "", "x": 38.57661532605132, "y": -122.51941521089782, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8c97a99f-545b-49cd-b1fe-4fd9e04bf37f", "name": "p1rdt9316lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b7d25399-f31a-4e49-adba-a78ff86c5b8b"}}}}, {"uuid": "be71b6c1-afc0-467f-8b9b-c08c14272f70", "name": "", "x": 38.57645998524856, "y": -122.51958447974425, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ef20846d-d685-4c65-8dfb-bc23317501c5", "name": "p1rlv20153", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be71b6c1-afc0-467f-8b9b-c08c14272f70"}}}}, {"uuid": "2a99897f-364d-411e-8bbe-72f557ebc745", "name": "", "x": 38.6051181986353, "y": -122.47354850924762, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a68a1c01-a04c-4af6-b1c8-02ddd1d67e0b", "name": "p1rdt9333lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2a99897f-364d-411e-8bbe-72f557ebc745"}}}}, {"uuid": "de597ed3-ec97-4454-aed4-09dd7a03ce13", "name": "", "x": 38.605233794489806, "y": -122.47322379683654, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "20f93381-3834-4265-b1ec-5767d171ce0a", "name": "p1rlv20182", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "de597ed3-ec97-4454-aed4-09dd7a03ce13"}}}}, {"uuid": "c9d78551-0fd5-43ed-8b68-579cb2336594", "name": "", "x": 38.589035386079345, "y": -122.51706377791538, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e98299cb-8bad-49ea-8627-f3cfe01b9e23", "name": "p1rdt9377lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c9d78551-0fd5-43ed-8b68-579cb2336594"}}}}, {"uuid": "d490540a-d433-41f2-b9e7-eca6fa93417a", "name": "", "x": 38.58906092117887, "y": -122.51702075225897, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fb7a8747-a076-469c-a150-35f6763157ec", "name": "p1rlv20277", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d490540a-d433-41f2-b9e7-eca6fa93417a"}}}}, {"uuid": "26eb7692-c5a5-4207-b2ef-2f5b4fc9f7de", "name": "", "x": 38.554956569072154, "y": -122.5078416303234, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9e37f182-5a60-470d-8f5b-ba145cc27973", "name": "p1rdt9381lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "26eb7692-c5a5-4207-b2ef-2f5b4fc9f7de"}}}}, {"uuid": "cff5bde2-44fa-4d0e-a743-f67d7e951b2c", "name": "", "x": 38.55506084687392, "y": -122.50759593781095, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3f23405b-432f-45ff-a7b1-0b7147cddfc8", "name": "p1rlv20281", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cff5bde2-44fa-4d0e-a743-f67d7e951b2c"}}}}, {"uuid": "095f699d-7656-4788-95ba-fb5548a06de8", "name": "", "x": 38.55481960527157, "y": -122.50809108490742, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9e5718ad-0b70-4ea4-b2f2-31f0ea5c5d5b", "name": "p1rlv20309", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "095f699d-7656-4788-95ba-fb5548a06de8"}}}}, {"uuid": "afabc397-de9a-4321-856d-b35e976cd844", "name": "", "x": 38.658604016675696, "y": -122.44126850823349, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "abd09ea6-221c-47d9-beec-1062e0dd4aa7", "name": "p1rdt9384lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "afabc397-de9a-4321-856d-b35e976cd844"}}}}, {"uuid": "fbc5a56d-565b-4454-b6d6-7d72d0bfe51f", "name": "", "x": 38.65866093691784, "y": -122.4412720400857, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25837ab0-0fb8-4346-94ad-561ff9ff7f0c", "name": "p1rlv20284", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fbc5a56d-565b-4454-b6d6-7d72d0bfe51f"}}}}, {"uuid": "1d71f24e-2901-42c3-a813-a3acd99d09c3", "name": "", "x": 38.55588955861104, "y": -122.50676017270496, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fc7e0a25-d6d6-4b07-b3dc-4fe5646915e2", "name": "p1rdt9396lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d71f24e-2901-42c3-a813-a3acd99d09c3"}}}}, {"uuid": "25e2bcaf-cac0-4e8f-91e9-d28d24280f7e", "name": "", "x": 38.55589072497332, "y": -122.5068140409716, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "da62d78e-e221-423a-8da0-8d36ce1f7508", "name": "p1rlv20300", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "25e2bcaf-cac0-4e8f-91e9-d28d24280f7e"}}}}, {"uuid": "1b4f1d5d-7d2c-437f-90c6-9aa0e49f8009", "name": "", "x": 38.62027530963716, "y": -122.47939957508689, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8180ee90-a46e-4d85-9742-d47b24f5e169", "name": "p1rdt9413lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1b4f1d5d-7d2c-437f-90c6-9aa0e49f8009"}}}}, {"uuid": "9fc146a4-e41f-4cf3-b41f-4854efeea77d", "name": "", "x": 38.62004720247463, "y": -122.47879011072362, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c23afdc0-ab93-4d43-8eec-613eab21cd74", "name": "p1rlv20333", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9fc146a4-e41f-4cf3-b41f-4854efeea77d"}}}}, {"uuid": "02cb45f3-fe94-4dd8-9573-6a0f478a879c", "name": "", "x": 38.620529773744515, "y": -122.47990087956352, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4b5d2dfa-895b-4afc-a7fe-449960adba41", "name": "p1rlv20358", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "02cb45f3-fe94-4dd8-9573-6a0f478a879c"}}}}, {"uuid": "e94a07cf-e35c-478c-a311-9ca498f5c3ae", "name": "", "x": 38.591063428696835, "y": -122.52153986948501, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a015abb-ec63-4b31-9314-283b8499646e", "name": "p1rdt9463lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e94a07cf-e35c-478c-a311-9ca498f5c3ae"}}}}, {"uuid": "25620ccf-e94e-4be9-bfe7-91878762980d", "name": "", "x": 38.59108896543552, "y": -122.52149684417888, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e4b5327a-85a3-496c-859c-f887a38513cd", "name": "p1rlv20432", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "25620ccf-e94e-4be9-bfe7-91878762980d"}}}}, {"uuid": "cca09bca-16e9-499c-b095-0c1950ecc547", "name": "", "x": 38.57979403494598, "y": -122.51418658341599, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4dbe1628-cd17-4f37-af2b-dd752c290fa4", "name": "p1rdt9468lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cca09bca-16e9-499c-b095-0c1950ecc547"}}}}, {"uuid": "e157a12b-a7d2-4147-bcd2-b3ab3a70ddae", "name": "", "x": 38.57980836535011, "y": -122.514237347121, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c37708d8-1e83-4e76-ac7f-0d29ba6b7c4e", "name": "p1rlv20451", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e157a12b-a7d2-4147-bcd2-b3ab3a70ddae"}}}}, {"uuid": "f80fb467-df08-4b12-85da-2108e641dcd6", "name": "", "x": 38.64987390299784, "y": -122.46561468579733, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "09613257-d4cb-4c50-b35a-8aefc637c0c9", "name": "p1rdt9469lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f80fb467-df08-4b12-85da-2108e641dcd6"}}}}, {"uuid": "a8be240d-00b9-4f9d-adf9-0f1168744f6a", "name": "", "x": 38.649915988400906, "y": -122.4656103988514, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a4e21b79-d2be-4a53-be46-32331e61f89c", "name": "p1rlv20453", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8be240d-00b9-4f9d-adf9-0f1168744f6a"}}}}, {"uuid": "8860d0ef-e55e-447d-93df-ae60d3936aa0", "name": "", "x": 38.65045746320294, "y": -122.46638434729005, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1ab8727-2758-4513-8a7d-e02381faf1e4", "name": "p1rdt9470lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8860d0ef-e55e-447d-93df-ae60d3936aa0"}}}}, {"uuid": "057230d4-bf01-4042-ad61-30c7db0f897e", "name": "", "x": 38.650379000628085, "y": -122.46634293498136, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9dfcfdbf-0051-4eef-bea6-97446cee21e4", "name": "p1rlv20459", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "057230d4-bf01-4042-ad61-30c7db0f897e"}}}}, {"uuid": "5cf1438a-80c4-4c22-aaed-3469743e85b4", "name": "", "x": 38.65057767311801, "y": -122.46643339731892, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9af153ed-ed39-4433-ac12-19dfdb7b6bef", "name": "p1rlv20499", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5cf1438a-80c4-4c22-aaed-3469743e85b4"}}}}, {"uuid": "7b65f4e9-580d-47dc-b34e-28f81d668390", "name": "", "x": 38.56377829551582, "y": -122.5132715911584, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c14c3211-a0d5-464f-820c-cab04764d907", "name": "p1rdt9473lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7b65f4e9-580d-47dc-b34e-28f81d668390"}}}}, {"uuid": "8a3e10a2-8282-43c8-b4da-fda1b1669c94", "name": "", "x": 38.5639962321023, "y": -122.51298713404236, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4759390d-43ec-45c9-9cca-320020dc1150", "name": "p1rlv20465", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8a3e10a2-8282-43c8-b4da-fda1b1669c94"}}}}, {"uuid": "cb26fbb7-596c-4de9-b34e-101dc678ca65", "name": "", "x": 38.5746780928461, "y": -122.51786998579286, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6a8f268-6a5a-4b23-bd91-53c6b031442a", "name": "p1rdt9479lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb26fbb7-596c-4de9-b34e-101dc678ca65"}}}}, {"uuid": "e39e8d8e-0d46-4628-94c5-07b594071e7e", "name": "", "x": 38.574723226995864, "y": -122.51801181420616, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cacd3e49-55aa-4f05-bd7d-ae8aba0af87f", "name": "p1rlv20502", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e39e8d8e-0d46-4628-94c5-07b594071e7e"}}}}, {"uuid": "7c12f6c5-55e6-49d1-bd94-2352ee3b1586", "name": "", "x": 38.65513908341776, "y": -122.34387958999741, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ac361065-6b3c-4ac6-96d5-9b474eb3b80f", "name": "p1rdt16638lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7c12f6c5-55e6-49d1-bd94-2352ee3b1586"}}}}, {"uuid": "0207b470-cf6d-4629-9b3c-ad531fda5dab", "name": "", "x": 38.655190554276075, "y": -122.34392111738993, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aa4eed95-33b7-4827-8744-52d14149b386", "name": "p1rlv38126", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0207b470-cf6d-4629-9b3c-ad531fda5dab"}}}}, {"uuid": "533bb500-770c-4d2c-9cc1-28775d01f44e", "name": "", "x": 38.65630824124314, "y": -122.34286109532569, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bae9a352-584d-4cf0-9ebd-eb280b684e78", "name": "p1rdt16725lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "533bb500-770c-4d2c-9cc1-28775d01f44e"}}}}, {"uuid": "ff5a7ad7-1d65-4c62-8ae0-267a310fb193", "name": "", "x": 38.65627492173817, "y": -122.34284238795301, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6cbb9976-253c-4863-899f-9218c4496688", "name": "p1rlv38269", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ff5a7ad7-1d65-4c62-8ae0-267a310fb193"}}}}, {"uuid": "f8eacce3-9525-4b06-8b1b-f7019fa7c45f", "name": "", "x": 38.62034621533613, "y": -122.43765627693834, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6bfb33cd-0cf1-455d-81e7-3d0472fa1b41", "name": "p1rdt8012", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f8eacce3-9525-4b06-8b1b-f7019fa7c45f"}}}}, {"uuid": "804049e0-ce7b-491e-99fa-e410e6a6a3be", "name": "", "x": 38.618246403950295, "y": -122.43508018831336, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e261b565-1f57-4cdc-bdd6-e045ee55d290", "name": "p1rdt7983", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "804049e0-ce7b-491e-99fa-e410e6a6a3be"}}}}, {"uuid": "6bfa5767-f2b2-4c1a-99b7-7b23d5fb2141", "name": "", "x": 38.620540310627334, "y": -122.43796845936235, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3f83d22a-fa1e-4a4e-aab9-a9dea8ee06e5", "name": "p1rdt8034", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6bfa5767-f2b2-4c1a-99b7-7b23d5fb2141"}}}}, {"uuid": "d27b544e-9687-455f-ba58-9ed436c5a572", "name": "", "x": 38.622378075951055, "y": -122.4397117047474, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "21e15d54-eab8-4204-9ed6-407fd8684700", "name": "p1rdt7954", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d27b544e-9687-455f-ba58-9ed436c5a572"}}}}, {"uuid": "81d253a0-1d96-4c57-8981-717e38dcce21", "name": "", "x": 38.62277584721677, "y": -122.43997282390552, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "016e4575-cd41-4993-be9b-5e5236a139ae", "name": "p1rdt7973", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "81d253a0-1d96-4c57-8981-717e38dcce21"}}}}, {"uuid": "4d3f203c-47be-4223-8720-2528ecc712e5", "name": "", "x": 38.62402950921016, "y": -122.44277403473237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ea481f8-b9c7-4067-9bfb-4f7cdc5dee15", "name": "p1rdt5172", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d3f203c-47be-4223-8720-2528ecc712e5"}}}}, {"uuid": "0e03e381-7790-4e61-94b7-9d458b302a4d", "name": "", "x": 38.62300895388021, "y": -122.44290656824234, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16712e10-4c7f-428b-917b-135ab3c2d4b3", "name": "p1rdt5155", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0e03e381-7790-4e61-94b7-9d458b302a4d"}}}}, {"uuid": "bf821b66-093f-4603-ad7e-32bed64b35bc", "name": "", "x": 38.623287659052096, "y": -122.4427643158668, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "afc636ed-f90c-4c48-822b-e86890d36f3b", "name": "p1rdt5155-p1rdt5172x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bf821b66-093f-4603-ad7e-32bed64b35bc"}}}}, {"uuid": "0363d42a-c376-4ae4-8b0d-bb484444fee6", "name": "", "x": 38.623116980624474, "y": -122.4447782161465, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9c289632-ba52-4b65-b6da-ac76b1477246", "name": "p1rdt5201", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0363d42a-c376-4ae4-8b0d-bb484444fee6"}}}}, {"uuid": "840097f5-3c7a-4849-b762-f137bdea4c16", "name": "", "x": 38.62329628881549, "y": -122.44457929911667, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ee606236-08d7-4258-96c9-e9104f15b467", "name": "p1rdt5159-p1rdt5201x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "840097f5-3c7a-4849-b762-f137bdea4c16"}}}}, {"uuid": "7f834bdd-4114-42ce-9e63-53bc785fec0a", "name": "", "x": 38.6234306387608, "y": -122.44440819183146, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "90fb2270-4759-4779-80c1-7f93d66e1c53", "name": "p1rdt5159", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7f834bdd-4114-42ce-9e63-53bc785fec0a"}}}}, {"uuid": "37141299-89a0-41ed-982a-51081d6b3d42", "name": "", "x": 38.62215863028796, "y": -122.44620579183537, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "86d3f96e-ffe2-459f-a2f1-b63d7bf138b8", "name": "p1rdt5180-p1rdt5201x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "37141299-89a0-41ed-982a-51081d6b3d42"}}}}, {"uuid": "6e4501c1-afa6-454f-bb4e-7186b7feb938", "name": "", "x": 38.615444643589946, "y": -122.4340993039006, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6fec8a81-a151-4d8f-adc7-6d6d87d7759f", "name": "p1rdt5923", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6e4501c1-afa6-454f-bb4e-7186b7feb938"}}}}, {"uuid": "da1cc01b-26a4-4326-b5b2-37141fb8691d", "name": "", "x": 38.61722132993687, "y": -122.42939704924423, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "14b429c3-41da-4123-b661-40cbdfaf33e0", "name": "p1rdt8346", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "da1cc01b-26a4-4326-b5b2-37141fb8691d"}}}}, {"uuid": "5a082e29-1507-4b02-b095-69b11f571dda", "name": "", "x": 38.617041139275344, "y": -122.43743292025952, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48e4b67a-0a47-48f0-b787-0a639db89caa", "name": "p1rdt7988", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5a082e29-1507-4b02-b095-69b11f571dda"}}}}, {"uuid": "4ed19a51-3310-41a4-aff9-28d8a46ca419", "name": "", "x": 38.62223049910566, "y": -122.44617598691588, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "893d2436-cd6c-40ad-90af-64ba1ac23f6e", "name": "p1rdt5180-p1rdt7988x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ed19a51-3310-41a4-aff9-28d8a46ca419"}}}}, {"uuid": "43402875-9dea-4473-be24-75b831aa6d6f", "name": "", "x": 38.62337315716766, "y": -122.45650688359399, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0089e5ea-d706-4a74-812f-654ae73eabcf", "name": "p1rdt8456", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "43402875-9dea-4473-be24-75b831aa6d6f"}}}}, {"uuid": "4cea5a72-5bb5-4f43-8eda-1ef360771178", "name": "", "x": 38.62156927448908, "y": -122.45679446794591, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "13b8cfc1-d8eb-4f47-b024-c1daacf3771d", "name": "p1rdt8447", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4cea5a72-5bb5-4f43-8eda-1ef360771178"}}}}, {"uuid": "cb3e167d-c2cb-4736-8f66-8143d56bd1cf", "name": "", "x": 38.6238198104542, "y": -122.456272029401, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "34054ef8-8942-4471-ac14-43c6a37e5a16", "name": "p1rdt8414-p1rdt8456x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb3e167d-c2cb-4736-8f66-8143d56bd1cf"}}}}, {"uuid": "8cb1f65f-d4fc-4d14-9857-6d98b2cc3094", "name": "", "x": 38.610218492856475, "y": -122.45635700104502, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8a53624b-8538-4cce-b588-c774875af31b", "name": "p1rdt6274", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8cb1f65f-d4fc-4d14-9857-6d98b2cc3094"}}}}, {"uuid": "fdc5de1c-ebb2-4bff-8945-795a93fc75f8", "name": "", "x": 38.61055108690851, "y": -122.4555659540378, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3ac93b23-1041-486e-a16e-861082c92f35", "name": "p1rdt6272-p1rdt6274x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fdc5de1c-ebb2-4bff-8945-795a93fc75f8"}}}}, {"uuid": "e57a56c3-8dcc-4aa1-91fc-48c8b8f06c8e", "name": "", "x": 38.610520720245056, "y": -122.45545884146962, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "034bda10-d48e-449c-9255-247cbf718683", "name": "p1rdt6272", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e57a56c3-8dcc-4aa1-91fc-48c8b8f06c8e"}}}}, {"uuid": "c16f990c-0ff1-414b-8380-ee7d791b0f96", "name": "", "x": 38.61197078011171, "y": -122.45741942756798, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0a75c5e2-2277-42b4-87d4-6eadff5c06f1", "name": "p1rdt6271", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c16f990c-0ff1-414b-8380-ee7d791b0f96"}}}}, {"uuid": "2dd1c6fe-9e94-4b4a-97e5-0fe2f1fb7e6d", "name": "", "x": 38.61207637689822, "y": -122.45737706222091, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "28954596-f060-4fa8-9f13-dfaa633bb739", "name": "p1rdt6270-p1rdt6271xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2dd1c6fe-9e94-4b4a-97e5-0fe2f1fb7e6d"}}}}, {"uuid": "0ca652d0-115a-441c-8eb8-5cf8c840706d", "name": "", "x": 38.6128563737481, "y": -122.45907473259327, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "898611f5-c343-4cca-8e5e-60cf0bfd796b", "name": "p1rdt6270-p1rdt6271xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0ca652d0-115a-441c-8eb8-5cf8c840706d"}}}}, {"uuid": "496b5d51-e112-464a-bb9c-4049894d8dee", "name": "", "x": 38.613028815797925, "y": -122.45946476660588, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b81bd5c2-96bb-445e-9eb8-d72360fd8a94", "name": "p1rdt6270-p1rdt6271xxxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "496b5d51-e112-464a-bb9c-4049894d8dee"}}}}, {"uuid": "d05a1a5c-0920-4097-babd-b5923ba0ddbd", "name": "", "x": 38.603726878082334, "y": -122.46288947925576, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "76f6a27f-0e4f-48b8-9dbd-31c6ffc4ec75", "name": "p1rdt7579", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d05a1a5c-0920-4097-babd-b5923ba0ddbd"}}}}, {"uuid": "417b978b-18e3-4121-a1bf-51f957cfd9dd", "name": "", "x": 38.60179587168076, "y": -122.46429351511154, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fa33ca9e-e16d-4c49-8a70-c6c30cf7b038", "name": "p1rdt7564", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "417b978b-18e3-4121-a1bf-51f957cfd9dd"}}}}, {"uuid": "38d20a1b-d399-4ab6-bf7c-aae66fa23a4c", "name": "", "x": 38.601539075146476, "y": -122.46251347070827, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8f2dabc2-0b52-490c-b13a-32c268f6bd33", "name": "p1rdt7588", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "38d20a1b-d399-4ab6-bf7c-aae66fa23a4c"}}}}, {"uuid": "4e241cc8-3082-4fd0-88d1-fc267588d21d", "name": "", "x": 38.60742474012847, "y": -122.4582846144434, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0f6de990-0988-4126-86ca-d1fd72c555fe", "name": "p1rdt7554", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4e241cc8-3082-4fd0-88d1-fc267588d21d"}}}}, {"uuid": "9b8ba534-6195-4b35-89f5-2a4c3c722bf4", "name": "", "x": 38.607801140709334, "y": -122.45761981019629, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2bdb2b51-0526-4995-bb5e-a2bd495488d4", "name": "p1rdt7554-p1rdt7570x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9b8ba534-6195-4b35-89f5-2a4c3c722bf4"}}}}, {"uuid": "4c45e384-de6e-47e6-a9ad-b6aae63c720c", "name": "", "x": 38.607753208324574, "y": -122.4554757397103, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f239ef4e-83f0-4a2c-ada3-8e30cef38472", "name": "p1rdt7559", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c45e384-de6e-47e6-a9ad-b6aae63c720c"}}}}, {"uuid": "3156fc94-96bd-4a53-b84b-3ddb7c65c545", "name": "", "x": 38.60740955675949, "y": -122.45440672587179, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ff343735-753a-48ca-92b1-ea778c9e0b5c", "name": "p1rdt7559-p1rdt8015x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3156fc94-96bd-4a53-b84b-3ddb7c65c545"}}}}, {"uuid": "e810c55c-bf24-40b9-8584-0ea6ba45bdd3", "name": "", "x": 38.60632927470628, "y": -122.45140187652409, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cc543f54-740b-4a7f-b1c5-eb3783a8ade0", "name": "p1rdt8015", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e810c55c-bf24-40b9-8584-0ea6ba45bdd3"}}}}, {"uuid": "7bf553bc-03a7-4134-b7e6-ce6194ed1aad", "name": "", "x": 38.60785880448065, "y": -122.45543337407624, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "09814176-7891-4fe1-addf-b47aa106c40d", "name": "p1rdt7559-p1rdt7570xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7bf553bc-03a7-4134-b7e6-ce6194ed1aad"}}}}, {"uuid": "2a3f447c-2df8-43bd-98a5-56059107b4e9", "name": "", "x": 38.607591729699735, "y": -122.45675980389136, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1dbec6c9-5c87-4f56-bd92-4a30d39ad094", "name": "p1rdt7559-p1rdt7570x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2a3f447c-2df8-43bd-98a5-56059107b4e9"}}}}, {"uuid": "3e452e28-6a28-4350-8544-cdbfbe2a921a", "name": "", "x": 38.601892868535366, "y": -122.45542862865831, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "db899c48-a801-4f83-b59d-e587ba80019d", "name": "p1rdt7552", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e452e28-6a28-4350-8544-cdbfbe2a921a"}}}}, {"uuid": "373ec05f-2d67-4736-8ebe-e41faea4f4ff", "name": "", "x": 38.60005814605219, "y": -122.4516448455036, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "93a5388e-ffd7-403e-b6cf-26b7e81feed1", "name": "p1rdt7986", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "373ec05f-2d67-4736-8ebe-e41faea4f4ff"}}}}, {"uuid": "fb5c1be3-22fd-4000-8e6b-267de4b40db1", "name": "", "x": 38.60314520391628, "y": -122.45852350850332, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2f0f3112-1395-48bf-88c1-8dd4b171478d", "name": "p1rdt7551", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fb5c1be3-22fd-4000-8e6b-267de4b40db1"}}}}, {"uuid": "928e2eec-1973-4044-bad0-d4fcdf464563", "name": "", "x": 38.60020849529689, "y": -122.46072753146206, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fc6bd64f-1ad3-4bd9-b590-7d4b673a94b5", "name": "p1rdt7561", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "928e2eec-1973-4044-bad0-d4fcdf464563"}}}}, {"uuid": "1741a3e1-3d98-4b45-9891-d9daf0f8513c", "name": "", "x": 38.60111102829196, "y": -122.46101936494843, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dead8520-e2f5-499b-9316-77780f9b1dfe", "name": "p1rdt7550", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1741a3e1-3d98-4b45-9891-d9daf0f8513c"}}}}, {"uuid": "af4f08f0-94de-4726-88ae-e00fcd4eaa36", "name": "", "x": 38.597594406004944, "y": -122.45741331498996, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f28de397-0db4-486a-8ce6-9f65c68703b3", "name": "p1rdt8434", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "af4f08f0-94de-4726-88ae-e00fcd4eaa36"}}}}, {"uuid": "45dc3818-21a6-4584-80fc-2019452cf93a", "name": "", "x": 38.597440760670644, "y": -122.45596586818255, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "184f95d4-cde1-4bf1-8a74-ebc7097cb10e", "name": "p1rdt8450", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "45dc3818-21a6-4584-80fc-2019452cf93a"}}}}, {"uuid": "799600d7-d852-4c9b-8f6e-1102fdded8ce", "name": "", "x": 38.597703329969455, "y": -122.45880555075607, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bbfe31b1-38ce-4ae4-9143-bf08c81617e8", "name": "p1rdt8440", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "799600d7-d852-4c9b-8f6e-1102fdded8ce"}}}}, {"uuid": "44c7d264-7191-4b9e-acb0-88e311db57b3", "name": "", "x": 38.59658206909063, "y": -122.45932321062192, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "516ca275-0d8e-4a9a-ab59-89cb66b95d93", "name": "p1rdt8436-p1rdt8440x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "44c7d264-7191-4b9e-acb0-88e311db57b3"}}}}, {"uuid": "9df146b4-516e-4ea5-bda7-c1a73ae15633", "name": "", "x": 38.59579222604902, "y": -122.46002037573007, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fcc42825-2690-4965-a99b-e78285a9b84e", "name": "p1rdt8436", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9df146b4-516e-4ea5-bda7-c1a73ae15633"}}}}, {"uuid": "c6913b29-d9ba-47a3-a192-1193e7e5403c", "name": "", "x": 38.596573779354905, "y": -122.45753186177956, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5f6e9b43-ceca-4a80-9569-696375a6ff5b", "name": "p1rdt8440-p1rdt8444x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c6913b29-d9ba-47a3-a192-1193e7e5403c"}}}}, {"uuid": "0a73aed7-d223-4038-9ac0-5b92a4d1987c", "name": "", "x": 38.5957635117617, "y": -122.45709408297363, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "685fbdbf-47af-4cc2-97ce-354dd04ce915", "name": "p1rdt8444", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a73aed7-d223-4038-9ac0-5b92a4d1987c"}}}}, {"uuid": "bf112380-b4c4-4738-a1d4-d798c1f01364", "name": "", "x": 38.599951855708426, "y": -122.46051919867074, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c0075333-98fe-4ee8-bb64-a18119b817c0", "name": "p1rdt7555", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bf112380-b4c4-4738-a1d4-d798c1f01364"}}}}, {"uuid": "f068e58c-2e16-4f15-8bf8-2f3eae98f96a", "name": "", "x": 38.601199336202434, "y": -122.46001207089114, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1e068b84-fbff-4546-b708-ca91ffe92b69", "name": "p1rdt7551-p1rdt7561x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f068e58c-2e16-4f15-8bf8-2f3eae98f96a"}}}}, {"uuid": "5cb7897b-26e3-4fb1-8110-0c2b58852939", "name": "", "x": 38.60649944562754, "y": -122.45751394231347, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1d8c14d0-8247-4a44-98c1-4534aa9037a2", "name": "p1rdt7551-p1rdt7574x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5cb7897b-26e3-4fb1-8110-0c2b58852939"}}}}, {"uuid": "7080975e-bc07-4286-ac0c-b487ce747aa8", "name": "", "x": 38.60635191905131, "y": -122.45581093557001, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ddf629eb-ea60-4fce-b731-7ebb33665829", "name": "p1rdt7553", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7080975e-bc07-4286-ac0c-b487ce747aa8"}}}}, {"uuid": "ece1113e-bcd2-4196-a2a1-14453f132e65", "name": "", "x": 38.606309626265485, "y": -122.45581243510644, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d4307e78-304a-4175-8e81-9cb23d99f394", "name": "p1rdt7572", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ece1113e-bcd2-4196-a2a1-14453f132e65"}}}}, {"uuid": "cbdc1d01-82c3-4ee4-babc-404553de25e5", "name": "", "x": 38.60642288565036, "y": -122.45576012137332, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f00dd033-8e7c-43af-bd16-1de2954e07be", "name": "p1rdt7553-p1rdt7574xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cbdc1d01-82c3-4ee4-babc-404553de25e5"}}}}, {"uuid": "c187bbb9-4399-4b90-a4f6-ea17d84c91b1", "name": "", "x": 38.60650133107034, "y": -122.45676802538416, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7744d8d9-73a8-4274-9c91-5542620942f5", "name": "p1rdt7553-p1rdt7574x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c187bbb9-4399-4b90-a4f6-ea17d84c91b1"}}}}, {"uuid": "e6eab6d5-ecec-4a44-9135-ace4449f9a3f", "name": "", "x": 38.616823684704634, "y": -122.45485169561282, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a9722136-480b-44cb-8b0e-0b3165712688", "name": "p1rdt5179-p1rdt6273x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e6eab6d5-ecec-4a44-9135-ace4449f9a3f"}}}}, {"uuid": "cbcad839-30cf-45d7-8aeb-5541d365147b", "name": "", "x": 38.61884536658003, "y": -122.45181991735679, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d22f1247-b756-4498-8cf8-fef7d1e859ff", "name": "p1rdt5179", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cbcad839-30cf-45d7-8aeb-5541d365147b"}}}}, {"uuid": "32980d01-7147-4efb-9208-6924bc7a6c36", "name": "", "x": 38.620392420969665, "y": -122.45625723062152, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "28af960e-6f27-483a-8029-0c5f1641f51d", "name": "p1rdt8408", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "32980d01-7147-4efb-9208-6924bc7a6c36"}}}}, {"uuid": "6eb63711-311c-48b0-a200-7708a569b3be", "name": "", "x": 38.62105939691115, "y": -122.45567255802798, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "433162b1-2a9b-4187-ba28-ec57503d76f6", "name": "p1rdt8458", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6eb63711-311c-48b0-a200-7708a569b3be"}}}}, {"uuid": "34790c46-d3a6-4ef4-a144-f8aa7791f306", "name": "", "x": 38.61794197262064, "y": -122.4571451861387, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "07f340ca-58c2-4331-8265-a39a45c87b75", "name": "p1rdt8439", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "34790c46-d3a6-4ef4-a144-f8aa7791f306"}}}}, {"uuid": "2882cbbd-35ac-40a5-8eba-2fa1353c5ab1", "name": "", "x": 38.619657499896064, "y": -122.45651946734527, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3430524c-820d-4f17-ba1b-377aeef4bbcd", "name": "p1rdt8408-p1rdt8439x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2882cbbd-35ac-40a5-8eba-2fa1353c5ab1"}}}}, {"uuid": "950056a4-f77d-43ed-abc8-f0ebb5f1eacf", "name": "", "x": 38.61643197384722, "y": -122.45750913060422, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "19d5304c-574f-4646-8095-d2dcbbea86e7", "name": "p1rdt6278-p1rdt8439x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "950056a4-f77d-43ed-abc8-f0ebb5f1eacf"}}}}, {"uuid": "46372221-c5d6-4e25-9937-70ae8e4a5744", "name": "", "x": 38.61757719949048, "y": -122.46073569903709, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a8c69243-872f-4e25-9d03-82692bbf8779", "name": "p1rdt8405-p1rdt8445x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "46372221-c5d6-4e25-9937-70ae8e4a5744"}}}}, {"uuid": "0193f084-2414-465f-8507-c518ab5551df", "name": "", "x": 38.61750461268671, "y": -122.46257773961285, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1e3ecdca-4b27-4a9d-8599-637924e86602", "name": "p1rdt8405-p1rdt8445xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0193f084-2414-465f-8507-c518ab5551df"}}}}, {"uuid": "559151e0-4417-49f0-a82d-3d35634b96df", "name": "", "x": 38.61747453032813, "y": -122.46077804087776, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bc0ee90f-1f9e-435e-bac4-86a4688c48fc", "name": "p1rdt8445", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "559151e0-4417-49f0-a82d-3d35634b96df"}}}}, {"uuid": "bd56f243-69e2-4d25-88e4-d5062a621ab9", "name": "", "x": 38.58085055283345, "y": -122.50956971443162, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bf648a0d-3262-4150-892b-55c3b117050a", "name": "p1rdt6500-p1rdt6519xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bd56f243-69e2-4d25-88e4-d5062a621ab9"}}}}, {"uuid": "4f978e8c-71c9-4108-8bd4-dd7e04c67d03", "name": "", "x": 38.58085769734513, "y": -122.50951590453553, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5789c3b2-eb91-4e4c-85e8-24f5893e1a2c", "name": "p1rdt6500-p1rdt6519xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4f978e8c-71c9-4108-8bd4-dd7e04c67d03"}}}}, {"uuid": "1a89ad58-99e8-48ca-b84d-4d30890fd198", "name": "", "x": 38.580324139975936, "y": -122.51120115232804, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c0824c21-244b-4d4e-85d6-238ac4908b5a", "name": "p1rdt6505-p1rdt6508x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1a89ad58-99e8-48ca-b84d-4d30890fd198"}}}}, {"uuid": "a9ea404f-0da3-492e-ad2b-10b63708892f", "name": "", "x": 38.57943061458019, "y": -122.51076650882104, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eb1c1e50-902d-443d-8c9a-b728d2f6b6f1", "name": "p1rdt6505", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a9ea404f-0da3-492e-ad2b-10b63708892f"}}}}, {"uuid": "845aaad9-1218-47c7-8b04-b96551dfcf6b", "name": "", "x": 38.57967511307611, "y": -122.5126018254279, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "66b7b2e9-7658-4de0-8197-3829c6179353", "name": "p1rdt6510-p1rdt6523x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "845aaad9-1218-47c7-8b04-b96551dfcf6b"}}}}, {"uuid": "0aa3f3d5-e5aa-42de-9954-8117a443544a", "name": "", "x": 38.57908668009848, "y": -122.5112130456528, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "848c04de-e4d5-4520-9dce-0073776c2ae4", "name": "p1rdt6510", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0aa3f3d5-e5aa-42de-9954-8117a443544a"}}}}, {"uuid": "80fce609-371e-4216-a76f-a73c72f53ba1", "name": "", "x": 38.57473976942866, "y": -122.51780959626444, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e07d8bc1-2f8a-4067-a2a7-b903dd042ce3", "name": "p1rdt5730-p1rdt9479x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "80fce609-371e-4216-a76f-a73c72f53ba1"}}}}, {"uuid": "ae73743c-8548-4137-a180-59f6280b9424", "name": "", "x": 38.57217576563056, "y": -122.51803280458198, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d5897bb2-1f72-4aeb-9090-74e2411b5786", "name": "p1rdt5730", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ae73743c-8548-4137-a180-59f6280b9424"}}}}, {"uuid": "ae5a3785-7653-4bf5-8675-35a3db35f092", "name": "", "x": 38.5747498946316, "y": -122.51790816237944, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e7f9286b-4209-402a-a365-1d27da4efb75", "name": "p1rdt5840-p1rdt9479x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ae5a3785-7653-4bf5-8675-35a3db35f092"}}}}, {"uuid": "693261a2-e33f-420e-98d7-aba12afe2b54", "name": "", "x": 38.57341254858641, "y": -122.51993371906103, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35722d90-049e-4c67-9654-acce0572e6c2", "name": "p1rdt5840", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "693261a2-e33f-420e-98d7-aba12afe2b54"}}}}, {"uuid": "a649e8d5-4a5d-4cc5-af0e-8100bd84e39b", "name": "", "x": 38.576726073438714, "y": -122.52446579115181, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "61ba1001-8b9d-481c-b205-45c6e0beadc1", "name": "p1rdt9298", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a649e8d5-4a5d-4cc5-af0e-8100bd84e39b"}}}}, {"uuid": "5ef16793-c098-41e2-b98c-4f9e4e7eefc7", "name": "", "x": 38.576522299104546, "y": -122.52532815241987, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f4a41fe9-62ce-45ba-abcd-086ba429baa0", "name": "p1rdt9302", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ef16793-c098-41e2-b98c-4f9e4e7eefc7"}}}}, {"uuid": "1dc016b2-4413-4089-9171-3916a1d89cab", "name": "", "x": 38.57714443025326, "y": -122.52236567259841, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3035d22c-c39f-4f07-9fe9-29888b16057d", "name": "p1rdt9310", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1dc016b2-4413-4089-9171-3916a1d89cab"}}}}, {"uuid": "b7ae5a8f-66ef-4d60-9134-78c031712321", "name": "", "x": 38.57657358147667, "y": -122.51940754990198, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "644c5887-31f1-436c-bbf6-dae5a70743a2", "name": "p1rdt9316", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b7ae5a8f-66ef-4d60-9134-78c031712321"}}}}, {"uuid": "8efefa1d-8ecd-4c4d-9e24-01b27035c531", "name": "", "x": 38.57940200391493, "y": -122.5212830170439, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b8721684-5439-482c-b8e5-be330d3cf745", "name": "p1rdt9312", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8efefa1d-8ecd-4c4d-9e24-01b27035c531"}}}}, {"uuid": "f194676e-4380-4328-ab02-daf91a9df474", "name": "", "x": 38.57641631447873, "y": -122.5192328534116, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7011f1dc-1e7d-4961-9a23-620b7f5737af", "name": "p1rdt9311", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f194676e-4380-4328-ab02-daf91a9df474"}}}}, {"uuid": "b9a6ab8a-47b8-4813-b138-81c932fd688f", "name": "", "x": 38.57548870286482, "y": -122.51882223524302, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "95d939ff-e20d-42b3-bb88-f1975f9fa0aa", "name": "p1rdt6518-p1rdt9311x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b9a6ab8a-47b8-4813-b138-81c932fd688f"}}}}, {"uuid": "659d0d06-e371-4b97-a79c-b5e43f8c7802", "name": "", "x": 38.56957251351933, "y": -122.5146506475286, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "77d2122b-cbb7-4844-bbb2-55e939431e50", "name": "p1rdt5729", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "659d0d06-e371-4b97-a79c-b5e43f8c7802"}}}}, {"uuid": "491c68dc-d6da-48bf-ae44-2d31c3d9cc06", "name": "", "x": 38.569500663957065, "y": -122.51470628390435, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "52f308f4-35db-49ec-a599-f8380489f952", "name": "p1rdt5729-p1rdt5731x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "491c68dc-d6da-48bf-ae44-2d31c3d9cc06"}}}}, {"uuid": "73967e47-18f3-483a-b10a-771124b63d48", "name": "", "x": 38.56683955344907, "y": -122.51476612858174, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "95cd61cf-f1cb-4af2-9d3b-e42978642003", "name": "p1rdt5731", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "73967e47-18f3-483a-b10a-771124b63d48"}}}}, {"uuid": "c7c257cd-2ea4-4e0e-9bb1-7f376fac96bf", "name": "", "x": 38.57065927664959, "y": -122.51444197635051, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b55c58cf-153e-4aa3-b099-8a1db05a6ae5", "name": "p1rdt5728", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c7c257cd-2ea4-4e0e-9bb1-7f376fac96bf"}}}}, {"uuid": "8ca253b4-42a5-4f7b-a94f-f26b95862d14", "name": "", "x": 38.57561216943165, "y": -122.51516613679155, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "66ef2ffb-e67d-47eb-ae59-194c538ab861", "name": "p1rdt5728-p1rdt6537x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8ca253b4-42a5-4f7b-a94f-f26b95862d14"}}}}, {"uuid": "34dad3c6-ccba-4a06-b54f-a9247d0f4c5f", "name": "", "x": 38.579768071852676, "y": -122.5141439807202, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9b5695dd-714e-4de1-a63a-f142ff0460e1", "name": "p1rdt9468", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "34dad3c6-ccba-4a06-b54f-a9247d0f4c5f"}}}}, {"uuid": "90fe05b7-f3d0-4489-a2c8-35e8cb9c8b41", "name": "", "x": 38.58086149565407, "y": -122.51897714369541, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e6348d4-7fcb-4546-af84-8ece75b6332f", "name": "p1rdt6502", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "90fe05b7-f3d0-4489-a2c8-35e8cb9c8b41"}}}}, {"uuid": "24c5be44-0224-48e1-b290-3d4953eec426", "name": "", "x": 38.580154407405615, "y": -122.51201736754072, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ddfa01c0-4d12-4f96-ab50-0082ef9914a6", "name": "p1rdt6501-p1rdt9468x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "24c5be44-0224-48e1-b290-3d4953eec426"}}}}, {"uuid": "93db63be-461c-4dab-8933-25baf8c11b03", "name": "", "x": 38.58045994181232, "y": -122.51074519698878, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7e4fd2ed-daa1-4a22-936f-8d51ee928d99", "name": "p1rdt6501-p1rdt9468x_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "93db63be-461c-4dab-8933-25baf8c11b03"}}}}, {"uuid": "10535ec6-eb7b-492e-a01d-5671139f021b", "name": "", "x": 38.58028290845341, "y": -122.51146113028999, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "42f09ae1-037a-4565-9cd2-0187c45b7866", "name": "p1rdt6509-p1rdt6514x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10535ec6-eb7b-492e-a01d-5671139f021b"}}}}, {"uuid": "0679c775-bf98-4471-bcd1-d965416cb97f", "name": "", "x": 38.580317644679276, "y": -122.51149205289134, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0737f6ec-0d5d-4cff-b4b7-9910c7076984", "name": "p1rdt6514", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0679c775-bf98-4471-bcd1-d965416cb97f"}}}}, {"uuid": "ecc88ed7-fb40-4552-8972-44bc465197f2", "name": "", "x": 38.57914402812339, "y": -122.51052209118085, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60b93cd6-c9fc-46ef-8b37-6b14d0773df6", "name": "p1rdt6498-p1rdt6516x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ecc88ed7-fb40-4552-8972-44bc465197f2"}}}}, {"uuid": "36242e7c-2807-441f-bc4d-826953103893", "name": "", "x": 38.578899383271626, "y": -122.51078551451845, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f5c5466f-b7e4-4844-967b-9e8b11c68b44", "name": "p1rdt6498", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "36242e7c-2807-441f-bc4d-826953103893"}}}}, {"uuid": "0317cab2-2dea-4ee4-9adb-5d6193ef7f1b", "name": "", "x": 38.566808328998086, "y": -122.50026076244916, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1f6ad7d-f7ea-4b94-956c-ec4a3b2028d5", "name": "p1rdt7298-p1rdt7313x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0317cab2-2dea-4ee4-9adb-5d6193ef7f1b"}}}}, {"uuid": "7eb6d4fd-b3a0-4a74-bd1c-256d42ed5872", "name": "", "x": 38.56643827491598, "y": -122.50011683345299, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b658bf21-450c-4e6b-9dec-c5023a05fd19", "name": "p1rdt7298", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7eb6d4fd-b3a0-4a74-bd1c-256d42ed5872"}}}}, {"uuid": "a581d35a-62ba-4b17-881e-badaf252f4fd", "name": "", "x": 38.56306630294141, "y": -122.50758361380268, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "28d17238-8db8-41da-960c-317183423576", "name": "p1rdt7036-p1rdt7091xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a581d35a-62ba-4b17-881e-badaf252f4fd"}}}}, {"uuid": "52b1a853-b828-4e73-b319-cc93eab563e6", "name": "", "x": 38.56354447960164, "y": -122.50839891620973, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "770cf0ab-50f1-489b-b2ea-d23ba186d10b", "name": "p1rdt7036-p1rdt7091x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "52b1a853-b828-4e73-b319-cc93eab563e6"}}}}, {"uuid": "54e92f2f-4588-4cda-9b5f-6f20e3c81165", "name": "", "x": 38.56300711787946, "y": -122.50763349737177, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "52068090-b613-46d7-a31f-ad3ca26382d5", "name": "p1rdt7036", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "54e92f2f-4588-4cda-9b5f-6f20e3c81165"}}}}, {"uuid": "3a0dbb41-c169-4ec0-8293-06ea239c1640", "name": "", "x": 38.562803482644604, "y": -122.51371079164413, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "97be7ac3-a710-4de8-a666-276813582cd6", "name": "p1rdt7620", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3a0dbb41-c169-4ec0-8293-06ea239c1640"}}}}, {"uuid": "b5ba243f-bb48-42fc-9d16-bfcab7c4716d", "name": "", "x": 38.56262386822574, "y": -122.51386121629318, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5bddd75e-1974-41ee-ab51-625c7485a573", "name": "p1rdt7627", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b5ba243f-bb48-42fc-9d16-bfcab7c4716d"}}}}, {"uuid": "e16bdb71-55c9-4a8f-8864-3327a56f5392", "name": "", "x": 38.56326190620687, "y": -122.51262082119965, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b3a4dfb4-e1b3-43b9-ae42-b0cec47ff4ad", "name": "p1rdt7311", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e16bdb71-55c9-4a8f-8864-3327a56f5392"}}}}, {"uuid": "4837ebc1-7a64-454a-95d7-ad5dc94def01", "name": "", "x": 38.56382004055108, "y": -122.51327924731947, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e4d8bafa-711d-4fd7-8374-7eeaeb43edcd", "name": "p1rdt9473", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4837ebc1-7a64-454a-95d7-ad5dc94def01"}}}}, {"uuid": "d1d35578-3675-44f4-b9e5-3512fa60f90f", "name": "", "x": 38.56294875123604, "y": -122.51180445263074, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "607c7275-da9a-4620-b019-59a66e98c2e6", "name": "p1rdt7306", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1d35578-3675-44f4-b9e5-3512fa60f90f"}}}}, {"uuid": "aa3b4b1d-2dd2-46e6-b28d-96be15961943", "name": "", "x": 38.5622926191724, "y": -122.5122220982717, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "56d67e3e-46af-4e2c-86a8-191d97b0ce8a", "name": "p1rdt7626", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aa3b4b1d-2dd2-46e6-b28d-96be15961943"}}}}, {"uuid": "8d521c86-54cb-4653-b5c6-8d9cae9e2cb8", "name": "", "x": 38.56302679357027, "y": -122.51026940176808, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3a65c4d3-2fc6-48c8-b944-68c4229db3dd", "name": "p1rdt7302", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8d521c86-54cb-4653-b5c6-8d9cae9e2cb8"}}}}, {"uuid": "a9e57660-7319-4bfc-a3d2-fcf715fdcfa9", "name": "", "x": 38.56309662911135, "y": -122.5097294573527, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "01c9d31d-c3bb-4950-9bbd-00377c252ddc", "name": "p1rdt7617", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a9e57660-7319-4bfc-a3d2-fcf715fdcfa9"}}}}, {"uuid": "c255184c-f2ed-4139-8383-2022a4b54427", "name": "", "x": 38.56316201817732, "y": -122.50953508538782, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a11cf3d9-90bb-4de8-b637-6ec9128525ec", "name": "p1rdt7617-p1rdt7625x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c255184c-f2ed-4139-8383-2022a4b54427"}}}}, {"uuid": "467d86b5-04a7-4310-966c-b874fd20f77e", "name": "", "x": 38.56129645031688, "y": -122.51025818859465, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "723e2b5c-414c-4f3d-ba23-d2df4bc63e75", "name": "p1rdt7630", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "467d86b5-04a7-4310-966c-b874fd20f77e"}}}}, {"uuid": "6edb6e11-ef87-458b-9e88-98c9e94188dc", "name": "", "x": 38.56190962697, "y": -122.51114576371964, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c7167a2e-9e83-441e-a15b-0256848c3f6d", "name": "p1rdt7616", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6edb6e11-ef87-458b-9e88-98c9e94188dc"}}}}, {"uuid": "b03f4ed4-9c9d-4423-9868-5308cb6b1368", "name": "", "x": 38.56171870357492, "y": -122.50994542040628, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aa48cf27-3b07-4460-ad9c-8d9862238645", "name": "p1rdt7621", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b03f4ed4-9c9d-4423-9868-5308cb6b1368"}}}}, {"uuid": "f92f9ef8-f56e-4f46-aa51-c53171f745c3", "name": "", "x": 38.56318612934499, "y": -122.50945665578503, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "53df7b6e-bd8c-43f2-860d-8869aec5d079", "name": "p1rdt7621-p1rdt7625x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f92f9ef8-f56e-4f46-aa51-c53171f745c3"}}}}, {"uuid": "7cf7bb6c-4bb7-464a-be3a-91cd2396461f", "name": "", "x": 38.55823465883282, "y": -122.50730279853406, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "08d3a02a-555d-4ad1-9b13-d413b7a16eef", "name": "p1rdt7090", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7cf7bb6c-4bb7-464a-be3a-91cd2396461f"}}}}, {"uuid": "3cc41f38-ab18-423e-8f7c-520e94039dcb", "name": "", "x": 38.558375802568776, "y": -122.50792515178091, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3cf406b-69e6-4aee-a6fc-272dad7693a4", "name": "p1rdt7054", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3cc41f38-ab18-423e-8f7c-520e94039dcb"}}}}, {"uuid": "685168bc-7964-448d-9c19-26d528fd2eae", "name": "", "x": 38.55914097308907, "y": -122.50637841432136, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aae22557-7d34-401d-82c9-2d2710ff2915", "name": "p1rdt7069", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "685168bc-7964-448d-9c19-26d528fd2eae"}}}}, {"uuid": "cfab6ae3-c499-4fe4-bd80-17d2c1ba2a07", "name": "", "x": 38.55990008450235, "y": -122.50687823607828, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f614382d-3883-4f6b-b1f6-c8e83d84ee22", "name": "p1rdt7087", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cfab6ae3-c499-4fe4-bd80-17d2c1ba2a07"}}}}, {"uuid": "73e43a9d-07db-47c1-94a1-988b0a844d27", "name": "", "x": 38.561212075777895, "y": -122.50733192344723, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8cebb186-4d9e-4d2c-b0d9-100056d34942", "name": "p1rdt7075", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "73e43a9d-07db-47c1-94a1-988b0a844d27"}}}}, {"uuid": "e987d9bf-0536-4244-9f47-a482bed25baa", "name": "", "x": 38.56134985808187, "y": -122.50795078492914, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "662e2a1c-9a54-4ac3-b478-98e3a478349d", "name": "p1rdt7080", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e987d9bf-0536-4244-9f47-a482bed25baa"}}}}, {"uuid": "db51b889-2677-4f16-9c3d-ee199f25a1a3", "name": "", "x": 38.56137014768056, "y": -122.50849010412762, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "161d6f3b-8bd9-4fa8-9442-c6ff008e8d3d", "name": "p1rdt7619", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "db51b889-2677-4f16-9c3d-ee199f25a1a3"}}}}, {"uuid": "c1c279b4-65c1-4732-a079-66f1aa2a03a9", "name": "", "x": 38.56077220663575, "y": -122.5085365470598, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "105df8ff-ec38-4cd6-b557-c318b4023bd0", "name": "p1rdt7615", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c1c279b4-65c1-4732-a079-66f1aa2a03a9"}}}}, {"uuid": "f337a156-4901-495b-b237-6edff9890775", "name": "", "x": 38.561738481750105, "y": -122.50901203752454, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b9e53141-a773-4127-9558-3887070a8f36", "name": "p1rdt7631", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f337a156-4901-495b-b237-6edff9890775"}}}}, {"uuid": "5ffbe342-0944-4873-987b-e7b8ca04bcbb", "name": "", "x": 38.56310083575031, "y": -122.50950410932236, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "460f5de9-8d4f-468a-b67a-b3b05354a9ce", "name": "p1rdt7625-p1rdt7631x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ffbe342-0944-4873-987b-e7b8ca04bcbb"}}}}, {"uuid": "4a433241-8ed9-4429-92a8-1ce38f0ba622", "name": "", "x": 38.5810553987312, "y": -122.5094376679452, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fec078c2-a5d8-4317-a8ac-bc25772f6358", "name": "p1rdt6515-p1rdt6535xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4a433241-8ed9-4429-92a8-1ce38f0ba622"}}}}, {"uuid": "d74595fc-2533-48bd-a6b5-323641953b72", "name": "", "x": 38.58105426448104, "y": -122.50949283188041, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f5a05d0e-8cf2-4ab8-bdfd-24b8cd12ad67", "name": "p1rdt6515-p1rdt6535xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d74595fc-2533-48bd-a6b5-323641953b72"}}}}, {"uuid": "5e32b2a0-a40b-4f7a-b599-26082e03f999", "name": "", "x": 38.58100676420751, "y": -122.50921942626415, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "04c1e05a-9cbb-4e53-9412-1cffd3976bed", "name": "p1rdt6515-p1rdt6536xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5e32b2a0-a40b-4f7a-b599-26082e03f999"}}}}, {"uuid": "f6d2dfe0-3d18-4c2c-b520-52cbb246dd08", "name": "", "x": 38.58098452673457, "y": -122.50917228702704, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5aa6899b-19a2-41e6-b445-f9fe2536c8d9", "name": "p1rdt6515-p1rdt6536xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f6d2dfe0-3d18-4c2c-b520-52cbb246dd08"}}}}, {"uuid": "995470a2-9f55-4576-97e3-0af02bcc170b", "name": "", "x": 38.58182522217373, "y": -122.50873063816502, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d21061fa-1011-44f7-8a20-26fcf0550f52", "name": "p1rdt8901-p1rdt8902x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "995470a2-9f55-4576-97e3-0af02bcc170b"}}}}, {"uuid": "1974122e-33d7-4966-a35c-5e21f25bdbb4", "name": "", "x": 38.581260006183335, "y": -122.50726033751013, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f23ab51c-56f3-4421-b66e-7cdcf109787d", "name": "p1rdt8901", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1974122e-33d7-4966-a35c-5e21f25bdbb4"}}}}, {"uuid": "6a6c8e90-6c34-4143-ae2d-51c7114ee9e2", "name": "", "x": 38.589021563154894, "y": -122.51711477621102, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "61972a50-ce24-4ec1-8535-402665b55a55", "name": "p1rdt9377", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a6c8e90-6c34-4143-ae2d-51c7114ee9e2"}}}}, {"uuid": "007ab400-5c36-4d26-ae49-7a6f16f74ac6", "name": "", "x": 38.58692523202436, "y": -122.52017146759988, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "84200441-4c26-4966-a4b7-6b91fb43f02e", "name": "p1rdt7301", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "007ab400-5c36-4d26-ae49-7a6f16f74ac6"}}}}, {"uuid": "bffa8083-006e-415c-b5d9-eb6a34928792", "name": "", "x": 38.581769930879894, "y": -122.50871878720857, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "43c862de-b014-4b24-8b34-54dae6edcf5a", "name": "p1rdt8902-p1rdt9377x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bffa8083-006e-415c-b5d9-eb6a34928792"}}}}, {"uuid": "de4f5afd-459e-4cbf-aa49-cd504cb83abb", "name": "", "x": 38.5814032621987, "y": -122.50967321866453, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32e86968-974e-4bcc-b562-1d4209771cf0", "name": "p1rdt8902-p1rdt9377x_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "de4f5afd-459e-4cbf-aa49-cd504cb83abb"}}}}, {"uuid": "6a742844-a654-453e-919e-80445d759442", "name": "", "x": 38.59300712782786, "y": -122.52139582849708, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "37c41a4b-e439-42a1-b9a7-0582c528f0e5", "name": "p1rdt8490", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a742844-a654-453e-919e-80445d759442"}}}}, {"uuid": "b6439b84-94cd-405b-b7ee-069f0c9d898c", "name": "", "x": 38.59104960383041, "y": -122.5215908683816, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "271ab023-4425-40d8-8080-2481c71309b5", "name": "p1rdt9463", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b6439b84-94cd-405b-b7ee-069f0c9d898c"}}}}, {"uuid": "39925f06-fa1e-450f-95b8-ba4e101482e4", "name": "", "x": 38.59323212584656, "y": -122.52027519448441, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "307d9c6d-d5ee-4490-95d3-5a9b1d171e54", "name": "p1rdt8492", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "39925f06-fa1e-450f-95b8-ba4e101482e4"}}}}, {"uuid": "39bd7fbf-764d-4497-aaba-76a78b273ff5", "name": "", "x": 38.59334183117795, "y": -122.52026098011822, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "605c34bc-3f7c-4eb7-8df0-fcd00d261921", "name": "p1rdt7599-p1rdt8492x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "39bd7fbf-764d-4497-aaba-76a78b273ff5"}}}}, {"uuid": "f5319190-a0b2-4d37-9550-a0f2b572bf96", "name": "", "x": 38.59572620360423, "y": -122.50628475874987, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3833996b-287c-4a13-9e7c-6834047f3691", "name": "p1rdt7599-p1rdt8492xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5319190-a0b2-4d37-9550-a0f2b572bf96"}}}}, {"uuid": "f38d56e1-87e0-41f8-b63c-a5019038e230", "name": "", "x": 38.60515752123577, "y": -122.47345444080051, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7f6d3fab-3b83-40c9-85c4-cfeddd0d317a", "name": "p1rdt6226-p1rdt9333xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f38d56e1-87e0-41f8-b63c-a5019038e230"}}}}, {"uuid": "7d2b8e82-3663-4e48-9e89-e8e528cc8114", "name": "", "x": 38.60491485090167, "y": -122.474443511017, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "76f24b35-1b82-4760-9817-80c166073f37", "name": "p1rdt6226-p1rdt9333x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7d2b8e82-3663-4e48-9e89-e8e528cc8114"}}}}, {"uuid": "68343b22-8902-4816-b01b-158043d770b3", "name": "", "x": 38.60439463477556, "y": -122.4756262540049, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d81fc6d7-3400-41d4-91d7-b350d7def98d", "name": "p1rdt6226", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "68343b22-8902-4816-b01b-158043d770b3"}}}}, {"uuid": "4f54bf78-ef0f-44fc-9eab-cf069c5c976f", "name": "", "x": 38.572765543379965, "y": -122.49283903354065, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "36c3c493-ff68-4bb8-a3f4-043c5f847bd3", "name": "p1rdt5650-p1rdt5662x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4f54bf78-ef0f-44fc-9eab-cf069c5c976f"}}}}, {"uuid": "a982988a-244f-4f1c-aac3-e1f1824ffd2c", "name": "", "x": 38.57146366361991, "y": -122.49011602390345, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c8f1c67e-9e29-45a3-a2a3-c2f3493a6898", "name": "p1rdt5650", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a982988a-244f-4f1c-aac3-e1f1824ffd2c"}}}}, {"uuid": "1f15fd9f-5dec-450c-985a-6838f958d682", "name": "", "x": 38.566867108561745, "y": -122.49714650199947, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "81f0e00e-bc49-448a-8e69-0569ed6a8c1a", "name": "p1rdt5658-p1rdt5663x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1f15fd9f-5dec-450c-985a-6838f958d682"}}}}, {"uuid": "f75a053a-7d19-4d97-a68d-be7390bb27ae", "name": "", "x": 38.56722225496197, "y": -122.49589645931059, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e67d07fb-aec5-4120-8254-32bfcd91e378", "name": "p1rdt5658-p1rdt5663xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f75a053a-7d19-4d97-a68d-be7390bb27ae"}}}}, {"uuid": "2fa9bd24-74db-46e1-9028-ab707e76db9d", "name": "", "x": 38.56676442477756, "y": -122.497188761547, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7356d982-36fd-46cb-9300-8889502e8dc8", "name": "p1rdt5663", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2fa9bd24-74db-46e1-9028-ab707e76db9d"}}}}, {"uuid": "825e0b55-7892-413f-9b90-fe1673ed473f", "name": "", "x": 38.563115754357725, "y": -122.50436551560664, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b470fa62-70d4-4cc5-8f7e-b9cda37481e0", "name": "p1rdt7067", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "825e0b55-7892-413f-9b90-fe1673ed473f"}}}}, {"uuid": "a92aaa91-6e7b-4ef0-9c9b-44040d044206", "name": "", "x": 38.562327045687596, "y": -122.50539247201371, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9bb8596a-bcb2-4282-bf1b-9939a9af87d9", "name": "p1rdt7046", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a92aaa91-6e7b-4ef0-9c9b-44040d044206"}}}}, {"uuid": "08c625af-eec7-4383-83b2-1f963a0cd6e9", "name": "", "x": 38.56260404120564, "y": -122.50270471808909, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fb3a9847-70d0-4004-95ef-63884c6c1cdc", "name": "p1rdt7038", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "08c625af-eec7-4383-83b2-1f963a0cd6e9"}}}}, {"uuid": "aeaaaaea-e526-430b-9d4a-421fafdb5bad", "name": "", "x": 38.562387612025795, "y": -122.4991118756889, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ac6e8ccf-75ec-42e0-a3cb-9ab86e2731a4", "name": "p1rdt7070", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aeaaaaea-e526-430b-9d4a-421fafdb5bad"}}}}, {"uuid": "635cd087-1d7c-47b3-b8a7-fec348f9b62f", "name": "", "x": 38.56242616294009, "y": -122.5018066922163, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e9cb2d8d-1991-463c-9e6b-88f5624f28c3", "name": "p1rdt7038-p1rdt7070x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "635cd087-1d7c-47b3-b8a7-fec348f9b62f"}}}}, {"uuid": "bcf8098e-ebef-4e7d-a388-84e59af95fb8", "name": "", "x": 38.55588435346, "y": -122.5067067908326, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0a597011-5e60-46fe-90d6-85728ff0ffa3", "name": "p1rdt9396", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bcf8098e-ebef-4e7d-a388-84e59af95fb8"}}}}, {"uuid": "09a7dcb1-00b7-4ecb-a625-2d5c4eed9235", "name": "", "x": 38.55491482364518, "y": -122.50783397819646, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b5791345-57dc-4f54-ab54-ea63e6a54ee0", "name": "p1rdt9381", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "09a7dcb1-00b7-4ecb-a625-2d5c4eed9235"}}}}, {"uuid": "53098f16-a96d-4396-ad7d-244d0c2c5f88", "name": "", "x": 38.557265355979126, "y": -122.50588266860625, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ac70c13b-5f4f-45f3-880a-b4b476ea552a", "name": "p1rdt7088", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "53098f16-a96d-4396-ad7d-244d0c2c5f88"}}}}, {"uuid": "c3e8351c-dd1c-4e18-b0d2-d7247c861a1f", "name": "", "x": 38.55764619612384, "y": -122.50520475670933, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "31cd4834-477f-4060-8efd-0504c8e8eaa9", "name": "p1rdt7089", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c3e8351c-dd1c-4e18-b0d2-d7247c861a1f"}}}}, {"uuid": "d29fd631-620d-43b6-846e-6fbd7db41afb", "name": "", "x": 38.55961566604152, "y": -122.50276328297903, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75947ffd-3765-443b-bef8-b6af746ef624", "name": "p1rdt7061", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d29fd631-620d-43b6-846e-6fbd7db41afb"}}}}, {"uuid": "81184bc6-d55f-4e11-abb5-4dbf0edbf6ab", "name": "", "x": 38.55890205970878, "y": -122.50382809113916, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "324f5d62-9feb-4fe4-bc1b-3dcf01898148", "name": "p1rdt7061-p1rdt7089x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "81184bc6-d55f-4e11-abb5-4dbf0edbf6ab"}}}}, {"uuid": "d9a8273a-d0fb-452e-b442-66d402d6ecf2", "name": "", "x": 38.560425566891645, "y": -122.50182050287499, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "84578de8-d5de-41fe-b637-42425e97b7db", "name": "p1rdt7061-p1rdt7070x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d9a8273a-d0fb-452e-b442-66d402d6ecf2"}}}}, {"uuid": "adff7086-5c4d-4692-ab27-39fd2c9e06e3", "name": "", "x": 38.56719749877506, "y": -122.49557460649763, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "02407b52-58c3-403c-9b5b-38695f435476", "name": "p1rdt5658-p1rdt7070x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "adff7086-5c4d-4692-ab27-39fd2c9e06e3"}}}}, {"uuid": "f380a6bd-42ac-4e94-852b-71eb43d521f4", "name": "", "x": 38.58873407774302, "y": -122.47343765394794, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c0843e99-e917-473c-bec7-ee0c3ddec601", "name": "p1rdt5017-p1rdt5200x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f380a6bd-42ac-4e94-852b-71eb43d521f4"}}}}, {"uuid": "21b5d83a-8c2e-4161-94a0-5316a279921c", "name": "", "x": 38.58804691015901, "y": -122.47096337199758, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "799ab435-c0a4-4515-8125-e8ca2fb7632d", "name": "p1rdt5200", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "21b5d83a-8c2e-4161-94a0-5316a279921c"}}}}, {"uuid": "44f794c1-8e6e-4411-a416-500797f57171", "name": "", "x": 38.599124013036686, "y": -122.46398556528375, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1b28595b-dcbe-4d1b-92c4-94acf370bb1f", "name": "p1rdt7576", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "44f794c1-8e6e-4411-a416-500797f57171"}}}}, {"uuid": "59b6cf59-ca9a-4f11-a6e9-118bc61c0fc8", "name": "", "x": 38.59899175164701, "y": -122.4633858496211, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4ce65512-7d5f-4514-b55c-1775e80dd94d", "name": "p1rdt8422", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59b6cf59-ca9a-4f11-a6e9-118bc61c0fc8"}}}}, {"uuid": "036c8efd-7db2-4870-82f2-3b943df50d82", "name": "", "x": 38.59980734698757, "y": -122.46809510052073, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75a31fa2-4df8-418a-a215-d0d450ced9a3", "name": "p1rdt7576-p1rdt8151xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "036c8efd-7db2-4870-82f2-3b943df50d82"}}}}, {"uuid": "5ddda534-1bae-4376-9940-923ffa5b0268", "name": "", "x": 38.59985029320267, "y": -122.46810315325398, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "df71ab4b-258c-4812-9537-6d425bacb468", "name": "p1rdt7576-p1rdt8151xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ddda534-1bae-4376-9940-923ffa5b0268"}}}}, {"uuid": "a77eb685-3722-4073-b5e1-fe119b376547", "name": "", "x": 38.59989292024887, "y": -122.46810581013978, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c951cf67-3297-407f-805c-55d9c03fb519", "name": "p1rdt7576-p1rdt8151x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a77eb685-3722-4073-b5e1-fe119b376547"}}}}, {"uuid": "63cc9012-4b26-4a85-b7cd-a17d2b412999", "name": "", "x": 38.59895094748302, "y": -122.46820159887727, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1613a53e-5194-4d26-b83b-475d9f02a32c", "name": "p1rdt8155", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "63cc9012-4b26-4a85-b7cd-a17d2b412999"}}}}, {"uuid": "e1bf1831-29fd-4c8c-a2d8-2caca097b732", "name": "", "x": 38.59895213180579, "y": -122.4682554984801, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b706c56-20f1-49ed-9cbe-0ec1491b83e0", "name": "p1rdt8149", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e1bf1831-29fd-4c8c-a2d8-2caca097b732"}}}}, {"uuid": "67b4a3bb-1120-4c1f-a699-5860c8fa90eb", "name": "", "x": 38.5924677842981, "y": -122.4635262800833, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8b423745-cc70-4c3a-adb0-f648170b4ab1", "name": "p1rdt8441", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "67b4a3bb-1120-4c1f-a699-5860c8fa90eb"}}}}, {"uuid": "a3ed93a5-c0ba-4cc1-ae05-71fcbd30574b", "name": "", "x": 38.59106375235361, "y": -122.46454322086704, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dac2cb8c-428b-49c4-8368-35608c050390", "name": "p1rdt5153-p1rdt8441xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a3ed93a5-c0ba-4cc1-ae05-71fcbd30574b"}}}}, {"uuid": "f0f6cd73-360a-4152-8fca-73066c995f16", "name": "", "x": 38.5891703292866, "y": -122.46631406470807, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dff898c1-a386-4219-9e8d-2d08b49f9098", "name": "p1rdt5153-p1rdt8441x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f0f6cd73-360a-4152-8fca-73066c995f16"}}}}, {"uuid": "0293898d-b01c-4468-ab99-40e98ee44971", "name": "", "x": 38.58821580644588, "y": -122.46709794144316, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eb8dae66-287a-4b8a-9cda-6ae02cb8f8a9", "name": "p1rdt5153", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0293898d-b01c-4468-ab99-40e98ee44971"}}}}, {"uuid": "94f325f3-6d2a-45bc-908f-e3cea41f7886", "name": "", "x": 38.59865977452597, "y": -122.46691737157991, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "78081763-07d2-4989-b492-e1c5178c4097", "name": "p1rdt8150", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "94f325f3-6d2a-45bc-908f-e3cea41f7886"}}}}, {"uuid": "fb3cd9d4-237f-4530-bd9a-6177b42a039b", "name": "", "x": 38.59382920785335, "y": -122.46428153625678, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "83b76782-be09-4733-a35c-6f3f26059a4d", "name": "p1rdt8150-p1rdt8441x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fb3cd9d4-237f-4530-bd9a-6177b42a039b"}}}}, {"uuid": "ba950250-6005-4961-ba68-6eea3fdd90dd", "name": "", "x": 38.59741418959317, "y": -122.46389890047125, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f2ef098d-d7e6-4530-a5cc-b6472ec9ffdc", "name": "p1rdt8150-p1rdt8442x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ba950250-6005-4961-ba68-6eea3fdd90dd"}}}}, {"uuid": "2202743d-a855-497a-87e1-851058c746c5", "name": "", "x": 38.597632581049226, "y": -122.46353019233372, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f6700763-e6dc-4626-ac2b-22985f0043be", "name": "p1rdt8442", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2202743d-a855-497a-87e1-851058c746c5"}}}}, {"uuid": "105d022a-345a-4dc1-add4-903d032442f7", "name": "", "x": 38.59878207629303, "y": -122.46742572315105, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b7280d1f-5ff9-45ee-9949-ecc70509a2a1", "name": "p1rdt8150-p1rdt8155x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "105d022a-345a-4dc1-add4-903d032442f7"}}}}, {"uuid": "358f69b2-02c9-48c0-8e3a-5a7b150a456d", "name": "", "x": 38.59899028699417, "y": -122.46961983252689, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9a30e197-897f-4516-b4e5-f70081e6f8c7", "name": "p1rdt8157", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "358f69b2-02c9-48c0-8e3a-5a7b150a456d"}}}}, {"uuid": "ae0a5a8f-0550-45d5-af05-1ee69e000ba1", "name": "", "x": 38.59975154279307, "y": -122.4680237146737, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b0a6628e-afc1-4daf-8a29-7626ac2aa5dd", "name": "p1rdt8151-p1rdt8155x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ae0a5a8f-0550-45d5-af05-1ee69e000ba1"}}}}, {"uuid": "2f1aa61f-7af2-40d3-b303-0f0bc8d88847", "name": "", "x": 38.64164273016234, "y": -122.45541248693772, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f903015c-95a7-4d6e-b2a5-e9705c050c6e", "name": "p1rdt5483", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2f1aa61f-7af2-40d3-b303-0f0bc8d88847"}}}}, {"uuid": "273a046e-c5ce-4125-9e31-028bb8292c8c", "name": "", "x": 38.64024304330955, "y": -122.45644844030662, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d29d8b74-a24d-4474-9752-c1ffa1aa7f7c", "name": "p1rdt5481", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "273a046e-c5ce-4125-9e31-028bb8292c8c"}}}}, {"uuid": "68c9a036-808f-4fad-8506-4a7896b8996d", "name": "", "x": 38.641756332042426, "y": -122.45557875811565, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2568f11c-8a37-4a55-8bce-9f0d56ac386a", "name": "p1rdt5480", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "68c9a036-808f-4fad-8506-4a7896b8996d"}}}}, {"uuid": "6a9bbaf7-c083-4fc4-802d-91e2d4b0f4db", "name": "", "x": 38.642142868875986, "y": -122.45608936956037, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a7d7f462-1ab5-4fd8-baaa-7e576eead5c7", "name": "p1rdt5477", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a9bbaf7-c083-4fc4-802d-91e2d4b0f4db"}}}}, {"uuid": "33ece59e-3a10-4c95-950d-ecedcc29e1d0", "name": "", "x": 38.64281235221596, "y": -122.45532194437911, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "df1d5615-4a0b-4041-8940-f13de9f7036a", "name": "p1rdt5477-p1rdt7201x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "33ece59e-3a10-4c95-950d-ecedcc29e1d0"}}}}, {"uuid": "000a5153-68d8-45da-89ab-617a8cd6cb36", "name": "", "x": 38.64321277078752, "y": -122.4548323247065, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f64ed4a2-6afb-447c-8c6b-15935e050a6d", "name": "p1rdt7201", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "000a5153-68d8-45da-89ab-617a8cd6cb36"}}}}, {"uuid": "f7c432d6-1633-4358-86dc-895b71dd2c40", "name": "", "x": 38.642219786001824, "y": -122.45774171841002, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a8c3f7f-b9be-4c5e-b6f0-8f2fc18935fa", "name": "p1rdt5472", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f7c432d6-1633-4358-86dc-895b71dd2c40"}}}}, {"uuid": "d7d5b93b-1a5a-4f71-95e8-3f2b1a9a411b", "name": "", "x": 38.64221051314406, "y": -122.45768209005053, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "595463a5-2019-4c94-b72d-c824c2aef347", "name": "p1rdt5472-p1rdt5477x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d7d5b93b-1a5a-4f71-95e8-3f2b1a9a411b"}}}}, {"uuid": "0d4453f9-bd03-4074-82f5-92e6944000d8", "name": "", "x": 38.63937777553964, "y": -122.46168143344667, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d69527e6-70b6-43e2-8b9e-7c8570ad5ddf", "name": "p1rdt5472-p1rdt5476x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0d4453f9-bd03-4074-82f5-92e6944000d8"}}}}, {"uuid": "7c7cf273-8a35-4f1b-b0df-652e02e8d7c4", "name": "", "x": 38.634273490971374, "y": -122.45107406346328, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "02ea9067-6a2a-48b6-b5f1-10992b9fbd77", "name": "p1rdt7704", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7c7cf273-8a35-4f1b-b0df-652e02e8d7c4"}}}}, {"uuid": "7f99c451-b1c2-40d3-9f37-2911f14e0083", "name": "", "x": 38.633218038007875, "y": -122.44832866649233, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f633393e-4d67-4646-838b-14f25641b426", "name": "p1rdt7704-p1rdt9266x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7f99c451-b1c2-40d3-9f37-2911f14e0083"}}}}, {"uuid": "983285a7-75f5-4a80-b562-57390f24885f", "name": "", "x": 38.63351410324478, "y": -122.44695962318366, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6fbb2bd0-d109-4248-85f3-266fe479677f", "name": "p1rdt9266", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "983285a7-75f5-4a80-b562-57390f24885f"}}}}, {"uuid": "91a6b8b3-39c6-43fb-9476-f82b581450b9", "name": "", "x": 38.63645110302719, "y": -122.45301866057562, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4462b9c6-748f-48e9-9ff9-7f20a06cf456", "name": "p1rdt7712", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "91a6b8b3-39c6-43fb-9476-f82b581450b9"}}}}, {"uuid": "c6e2115c-5e23-404f-8d02-cfc7459bceb4", "name": "", "x": 38.63434015287993, "y": -122.45255214689988, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "048e2bab-67f2-4975-81a1-bbc9f2f9cd88", "name": "p1rdt7718", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c6e2115c-5e23-404f-8d02-cfc7459bceb4"}}}}, {"uuid": "b8a68cb6-346c-42b7-abe2-6eed14ab959d", "name": "", "x": 38.636858070821944, "y": -122.45332579295936, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "74968ebc-53c5-4fc6-8172-3ffa9dea7683", "name": "p1rdt7701", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b8a68cb6-346c-42b7-abe2-6eed14ab959d"}}}}, {"uuid": "a9d37e1d-5173-4635-a52b-7cf55ef8c650", "name": "", "x": 38.63763391930191, "y": -122.4535037389147, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ec849ee4-3d69-46a9-9a2a-242a3943e46c", "name": "p1rdt7699", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a9d37e1d-5173-4635-a52b-7cf55ef8c650"}}}}, {"uuid": "4260e8f1-7798-4deb-9e31-1fca3abf1a52", "name": "", "x": 38.63933239277819, "y": -122.45585430535672, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3cfb3a23-3a93-4d89-8b70-e4730ebbce1a", "name": "p1rdt5485", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4260e8f1-7798-4deb-9e31-1fca3abf1a52"}}}}, {"uuid": "bc656b69-36a4-43ff-b71d-c180a2f08d8e", "name": "", "x": 38.638463291461264, "y": -122.45417138292237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "890cd47a-994b-4dca-8d59-25164f04c927", "name": "p1rdt5485-p1rdt7699x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bc656b69-36a4-43ff-b71d-c180a2f08d8e"}}}}, {"uuid": "6a726f29-4815-4b7e-9cdd-3ba9cab41478", "name": "", "x": 38.639561691754864, "y": -122.45649160162748, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2b9e57e0-6dc8-4831-ac7d-36f8608b7a8d", "name": "p1rdt5475", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a726f29-4815-4b7e-9cdd-3ba9cab41478"}}}}, {"uuid": "ea984b77-b138-4d35-84e2-6f5e1b3be68a", "name": "", "x": 38.63942177536906, "y": -122.46162651516015, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ae343ca3-3337-4528-b117-38a51e6d023f", "name": "p1rdt5475-p1rdt5476x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea984b77-b138-4d35-84e2-6f5e1b3be68a"}}}}, {"uuid": "c6a41314-ff2d-43b3-b5cc-6e2a28deffa6", "name": "", "x": 38.63947133387594, "y": -122.46167250985621, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4c977e6c-43f0-4d7e-b19f-82f0de97dab2", "name": "p1rdt5476-p1rdt5478x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c6a41314-ff2d-43b3-b5cc-6e2a28deffa6"}}}}, {"uuid": "4979c1e5-b450-4e65-96a4-18e6717e9de6", "name": "", "x": 38.637232713702204, "y": -122.4583095586275, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9a97491e-2c98-4584-9b74-5593f17faeda", "name": "p1rdt5478", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4979c1e5-b450-4e65-96a4-18e6717e9de6"}}}}, {"uuid": "2eb92f32-3756-41cd-b0da-65a66c24a381", "name": "", "x": 38.629275148712736, "y": -122.45440586693407, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "96399e51-1243-4e7f-ae3a-5e2c67123aae", "name": "p1rdt6848", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2eb92f32-3756-41cd-b0da-65a66c24a381"}}}}, {"uuid": "02d00be7-cb00-4607-bd85-777ce7f0a710", "name": "", "x": 38.62915793743979, "y": -122.45307010539497, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2b764d22-debb-4d88-8221-ff79307e609f", "name": "p1rdt6848-p1rdt9264x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "02d00be7-cb00-4607-bd85-777ce7f0a710"}}}}, {"uuid": "2777bf8f-fb4b-4519-88c5-7462abde8f9a", "name": "", "x": 38.62929755153899, "y": -122.45269743640755, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6bdf3994-bb0c-44f4-b1ea-ab29e73bd39c", "name": "p1rdt9264", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2777bf8f-fb4b-4519-88c5-7462abde8f9a"}}}}, {"uuid": "d6f76c08-aa28-4f37-96e7-37ad79f4b724", "name": "", "x": 38.63204510201893, "y": -122.46437683506844, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3e92b102-eaee-41cc-a2fc-c6c4b3bfb58b", "name": "p1rdt6847", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d6f76c08-aa28-4f37-96e7-37ad79f4b724"}}}}, {"uuid": "597d61bf-b7a2-48d5-9bb2-6befc99d855a", "name": "", "x": 38.637551036439916, "y": -122.4658407872937, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be9350ab-7ad2-4a89-a374-94bf69588d7f", "name": "p1rdt6847-p1rdt7624x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "597d61bf-b7a2-48d5-9bb2-6befc99d855a"}}}}, {"uuid": "854252b7-a9be-439b-b237-47caad78812a", "name": "", "x": 38.63745413036962, "y": -122.41088901665674, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4d6c5b78-35c4-475a-8837-776dea236c95", "name": "p1rdt6348", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "854252b7-a9be-439b-b237-47caad78812a"}}}}, {"uuid": "601cbd90-802e-4147-93e4-1a0dee2ea031", "name": "", "x": 38.63621334895868, "y": -122.41023104176281, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c935f1c0-e36c-407d-a2e8-4181c4b0733e", "name": "p1rdt6350", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "601cbd90-802e-4147-93e4-1a0dee2ea031"}}}}, {"uuid": "e5e50d5c-d080-4d8d-b9cf-869a003ee1f5", "name": "", "x": 38.635943272929005, "y": -122.41464349224492, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "40280da5-767c-4610-b6a8-ff411e1c33e8", "name": "p1rdt6345", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e5e50d5c-d080-4d8d-b9cf-869a003ee1f5"}}}}, {"uuid": "2fb72ea7-b013-493a-940f-9e1e8a973dd2", "name": "", "x": 38.637135599334236, "y": -122.41985198242058, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1bdfc1ac-98a4-43dd-bb2c-837d0a2c15f9", "name": "p1rdt6356", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2fb72ea7-b013-493a-940f-9e1e8a973dd2"}}}}, {"uuid": "65123f8f-99b8-4bc5-a743-806f7f6963d0", "name": "", "x": 38.63428208141972, "y": -122.41685332058216, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8e51e0d9-24b6-40ac-859a-51ea74c93e76", "name": "p1rdt6353", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65123f8f-99b8-4bc5-a743-806f7f6963d0"}}}}, {"uuid": "ad2a38c2-3edd-4b63-9187-242b9e02e7b1", "name": "", "x": 38.637037161169054, "y": -122.41998840936154, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2040b1a2-85bc-405a-9dab-138561b5e3ac", "name": "p1rdt6354-p1rdt6356x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ad2a38c2-3edd-4b63-9187-242b9e02e7b1"}}}}, {"uuid": "3be1ed3b-9da6-42c9-8228-52e392d086e4", "name": "", "x": 38.6365030259924, "y": -122.42074352091329, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1a05e7c9-4bff-46fd-b356-8120b481b053", "name": "p1rdt6354", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3be1ed3b-9da6-42c9-8228-52e392d086e4"}}}}, {"uuid": "150904ad-1522-4a28-9697-1c2bfb036cd7", "name": "", "x": 38.63888731873398, "y": -122.42664972566449, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c7166849-6ecd-4270-bf52-d0579838336a", "name": "p1rdt6347", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "150904ad-1522-4a28-9697-1c2bfb036cd7"}}}}, {"uuid": "4d009f86-5794-4639-91c0-2a5ac3e6cdce", "name": "", "x": 38.63046949482658, "y": -122.42586839274048, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6e36f1f1-6993-46b0-bafa-9530fd1652ef", "name": "p1rdt7605", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d009f86-5794-4639-91c0-2a5ac3e6cdce"}}}}, {"uuid": "4ae5dbc6-e0bc-49e8-b304-6f7ac9362bd2", "name": "", "x": 38.63106444152601, "y": -122.42668905474402, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f95e5fa5-a84c-42a4-b519-8d344e816ecd", "name": "p1rdt7598", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ae5dbc6-e0bc-49e8-b304-6f7ac9362bd2"}}}}, {"uuid": "a5f8fa10-b048-48a1-860f-3b120eb360fa", "name": "", "x": 38.632704736208574, "y": -122.42169322012252, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5f9809eb-41e0-40a8-b43a-93556f767f68", "name": "p1rdt7589", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a5f8fa10-b048-48a1-860f-3b120eb360fa"}}}}, {"uuid": "0ce8819e-f17b-461b-8c62-5afbaabea831", "name": "", "x": 38.62803766509506, "y": -122.4206605617657, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3410d88a-3e9c-427e-a79e-5c602455ed1d", "name": "p1rdt7612", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0ce8819e-f17b-461b-8c62-5afbaabea831"}}}}, {"uuid": "5d59340d-16c5-4b89-8091-5c32f734632c", "name": "", "x": 38.64794018977543, "y": -122.44170447330542, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6163371c-55ef-4900-a3ef-2e4e8fc2894a", "name": "p1rdt6347-p1rdt8470x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5d59340d-16c5-4b89-8091-5c32f734632c"}}}}, {"uuid": "1965718d-a8b3-400b-a48b-dcee8657a6ac", "name": "", "x": 38.65468732876317, "y": -122.39725551743196, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "769c14db-ac3f-438d-9f7d-c7eb2d3074b5", "name": "p1rdt5653", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1965718d-a8b3-400b-a48b-dcee8657a6ac"}}}}, {"uuid": "29c6209f-ca61-4fb8-987f-c2da46ad0d9b", "name": "", "x": 38.65539216836069, "y": -122.39642965058673, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "98f2c16a-cdbd-49a3-b60d-4be6e9158480", "name": "p1rdt5218-p1rdt5653x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "29c6209f-ca61-4fb8-987f-c2da46ad0d9b"}}}}, {"uuid": "9ccf40bd-2c7a-40e1-a90b-72438700a78e", "name": "", "x": 38.65638553565669, "y": -122.3958356267157, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9dda7f7c-3b21-46a0-88a3-2b7f028b7772", "name": "p1rdt5218", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9ccf40bd-2c7a-40e1-a90b-72438700a78e"}}}}, {"uuid": "c08bee5c-777a-4666-8eec-9b3dd673bfbc", "name": "", "x": 38.649267204221246, "y": -122.40284351830519, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "58c6d858-d457-4fe6-a45b-b9b2b73cad8c", "name": "p1rdt5195", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c08bee5c-777a-4666-8eec-9b3dd673bfbc"}}}}, {"uuid": "f1105e91-4b0f-4530-adf0-ed1cb33735f5", "name": "", "x": 38.649760224171196, "y": -122.40177465588245, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fbc486eb-4f08-4602-a101-1298d4a46b32", "name": "p1rdt5195_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f1105e91-4b0f-4530-adf0-ed1cb33735f5"}}}}, {"uuid": "49651b45-fc27-43ca-af8d-9789a4a6004a", "name": "", "x": 38.648493079669315, "y": -122.39370880076001, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3741c9d4-d03a-4b2f-be57-52a8977351ad", "name": "p1rdt6995", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "49651b45-fc27-43ca-af8d-9789a4a6004a"}}}}, {"uuid": "4b0305c0-1037-4ef4-949a-597397ef270e", "name": "", "x": 38.648911595375175, "y": -122.39447297420028, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2d4d11a9-8de3-4dbe-8974-6005ed40f363", "name": "p1rdt6995-p1rdt7015x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4b0305c0-1037-4ef4-949a-597397ef270e"}}}}, {"uuid": "a7bc3009-8e8d-4e17-b616-c76252626a6c", "name": "", "x": 38.64914243697819, "y": -122.39455192500522, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6278a0d-f5d3-4b11-aee9-3bb23f9954a8", "name": "p1rdt7015", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a7bc3009-8e8d-4e17-b616-c76252626a6c"}}}}, {"uuid": "abb1e08a-855e-4897-a673-308816a942cc", "name": "", "x": 38.65509732869403, "y": -122.34387202316023, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6c0d417e-c787-4b0a-a39e-b19ef274b36b", "name": "p1rdt16638", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "abb1e08a-855e-4897-a673-308816a942cc"}}}}, {"uuid": "8297b428-5b23-4152-ab9c-87c2979a4b24", "name": "", "x": 38.656349996019614, "y": -122.34286866169235, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c2d0eb0b-bbb6-4b3e-bdc6-4c8a0e7d466f", "name": "p1rdt16725", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8297b428-5b23-4152-ab9c-87c2979a4b24"}}}}, {"uuid": "9a600806-0174-49eb-91db-fe69ef61fe1b", "name": "", "x": 38.65481285259022, "y": -122.34567144468134, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ddb8e50b-2619-4e74-aee6-84dc4e11389e", "name": "p1rdt16638-p1rdt6995x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9a600806-0174-49eb-91db-fe69ef61fe1b"}}}}, {"uuid": "39e782d2-a807-49ed-80d0-94565d915d21", "name": "", "x": 38.649657570740004, "y": -122.40108599864732, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9056795d-5c81-4fb9-96bc-51d63b32b187", "name": "p1rdt5195-p1rdt6995x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "39e782d2-a807-49ed-80d0-94565d915d21"}}}}, {"uuid": "cd10cffe-a98a-4acd-b67f-fc34e733b7f8", "name": "", "x": 38.647538844802774, "y": -122.40874594362695, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "227d848c-cddc-4561-996b-f8f7a60a5a89", "name": "p1rdt5195-p1rdt5202xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cd10cffe-a98a-4acd-b67f-fc34e733b7f8"}}}}, {"uuid": "089f2e83-3db8-4d79-9106-f2ded1bf5cc7", "name": "", "x": 38.64780415928914, "y": -122.40698510373619, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "43e1b69a-c6dd-447e-82d9-921998de9837", "name": "p1rdt5195-p1rdt5202xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "089f2e83-3db8-4d79-9106-f2ded1bf5cc7"}}}}, {"uuid": "26852e48-00b2-4987-9615-bb92ddc4d19d", "name": "", "x": 38.64819471408059, "y": -122.40580973948633, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8e2f2704-4dee-4c78-b199-256b907156f3", "name": "p1rdt5195-p1rdt5202x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "26852e48-00b2-4987-9615-bb92ddc4d19d"}}}}, {"uuid": "5ce2d535-677f-4124-97e4-ce80c6f3a10b", "name": "", "x": 38.64756484598567, "y": -122.4087885476493, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "97e4f179-9d60-4183-8326-eb0ab98a53eb", "name": "p1rdt5202", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ce2d535-677f-4124-97e4-ce80c6f3a10b"}}}}, {"uuid": "2e5194ca-81e3-4cce-b22d-e2f1ba68986d", "name": "", "x": 38.646212863621486, "y": -122.4077336633597, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "17fedb14-6008-43fd-b7e9-342a113f27a6", "name": "p1rdt5202-p1rdt5206x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2e5194ca-81e3-4cce-b22d-e2f1ba68986d"}}}}, {"uuid": "87956ea9-4e14-4028-a086-a242d4767471", "name": "", "x": 38.64569758673296, "y": -122.40751541256846, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2ed081eb-6b56-43b8-9cf8-e7ffdd8222f2", "name": "p1rdt5206", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "87956ea9-4e14-4028-a086-a242d4767471"}}}}, {"uuid": "f78d39fc-8180-40e0-b698-65cd5bfa44c7", "name": "", "x": 38.65086417573999, "y": -122.42606190704704, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a21680f1-33a7-44e1-9293-98c6861ba2a5", "name": "p1rdt7268", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f78d39fc-8180-40e0-b698-65cd5bfa44c7"}}}}, {"uuid": "70e977d3-80cc-4570-8493-adcde3e97600", "name": "", "x": 38.64877414711051, "y": -122.41168870941135, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6e61d2f-f75e-4335-aec9-4722942be9f1", "name": "p1rdt5202-p1rdt7268x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "70e977d3-80cc-4570-8493-adcde3e97600"}}}}, {"uuid": "72701ad2-e31a-4773-8b69-a2d3ae194283", "name": "", "x": 38.64212986886906, "y": -122.42144512012567, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "88cc1382-6b14-4500-8a21-662fce6a0c0b", "name": "p1rdt6355", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "72701ad2-e31a-4773-8b69-a2d3ae194283"}}}}, {"uuid": "c0ec56eb-72c0-4ca6-8556-375e1b1f7cc1", "name": "", "x": 38.64194634219145, "y": -122.4207801394437, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3c1edcfa-e0e4-4493-a9bb-e6033185ce67", "name": "p1rdt6349", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c0ec56eb-72c0-4ca6-8556-375e1b1f7cc1"}}}}, {"uuid": "bf893988-405e-4ab8-b905-b745f43a9a00", "name": "", "x": 38.64540330832493, "y": -122.421204010774, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eeab7dfa-540c-4275-b159-f6ac4d1350f9", "name": "p1rdt7224", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bf893988-405e-4ab8-b905-b745f43a9a00"}}}}, {"uuid": "a6dbd015-0a15-482b-9236-103a366e1112", "name": "", "x": 38.64637376282259, "y": -122.41881749796097, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b0fef9b3-a4bd-421c-8a54-cbf6f44c460d", "name": "p1rdt7618", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a6dbd015-0a15-482b-9236-103a366e1112"}}}}, {"uuid": "4c5c6dcd-63b8-41a2-8093-8cca2d72aeea", "name": "", "x": 38.649069267013274, "y": -122.42574072103456, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "22978d10-c9dc-4c84-8025-5749c730daa6", "name": "p1rdt7224-p1rdt7268x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c5c6dcd-63b8-41a2-8093-8cca2d72aeea"}}}}, {"uuid": "c46f4e0b-dc3c-4a3f-be3f-38e560bf6190", "name": "", "x": 38.64786537466463, "y": -122.44168489363972, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6225b33-2abc-4f77-9d65-459794f56353", "name": "p1rdt7268-p1rdt8470x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c46f4e0b-dc3c-4a3f-be3f-38e560bf6190"}}}}, {"uuid": "927a4063-4d22-46e6-ac4f-c015458ef7d8", "name": "", "x": 38.65324099971405, "y": -122.46490061193234, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "97198258-8ba3-4950-8747-3241c6a4fcee", "name": "p1rdt7790", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "927a4063-4d22-46e6-ac4f-c015458ef7d8"}}}}, {"uuid": "8f7b0799-74df-4334-8e29-dd46150745c8", "name": "", "x": 38.65493103663836, "y": -122.46522487253812, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "62078787-3ae2-47b3-8f67-8e89e110c8be", "name": "p1rdt7735", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8f7b0799-74df-4334-8e29-dd46150745c8"}}}}, {"uuid": "d818e1c1-0ba9-41c1-a9de-6fd225be8ae4", "name": "", "x": 38.651340821800964, "y": -122.4634244039528, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "15a7847f-aa96-4206-b4c6-422802f4e0a6", "name": "p1rdt7790-p1rdt9090x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d818e1c1-0ba9-41c1-a9de-6fd225be8ae4"}}}}, {"uuid": "fb91d7f3-340f-4966-b7e0-d358967a4734", "name": "", "x": 38.65962472553894, "y": -122.44176628998517, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "26613f51-86bf-4ae1-86c0-f23e48cf606e", "name": "p1rdt8911", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fb91d7f3-340f-4966-b7e0-d358967a4734"}}}}, {"uuid": "1bab182c-4582-47c6-8d17-29842e513a82", "name": "", "x": 38.65931212124818, "y": -122.44176119733557, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7bc7d623-3ca7-4c4e-b11c-f373e90d06b6", "name": "p1rdt8911-p1rdt9384x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1bab182c-4582-47c6-8d17-29842e513a82"}}}}, {"uuid": "b5c3aa09-2214-445c-bfa5-3d3f96eb953f", "name": "", "x": 38.65864576551388, "y": -122.44127613204223, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6eb9c7a5-5ab1-4d9b-a59e-538b68ad0bb9", "name": "p1rdt9384", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b5c3aa09-2214-445c-bfa5-3d3f96eb953f"}}}}, {"uuid": "92919a40-4844-490d-a018-5e9680adcac0", "name": "", "x": 38.660983681991716, "y": -122.44208551181131, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "924fc042-6ddc-484b-b09f-c65b35817d25", "name": "p1rdt8905", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "92919a40-4844-490d-a018-5e9680adcac0"}}}}, {"uuid": "b8032e4e-ca80-4e94-918c-c9de73f29a0c", "name": "", "x": 38.66020225533911, "y": -122.44026057728638, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "adcc33f8-72a3-434c-a021-6c5973713a91", "name": "p1rdt8916", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b8032e4e-ca80-4e94-918c-c9de73f29a0c"}}}}, {"uuid": "1df05fd9-2ce1-423d-a9c2-c03c77b85391", "name": "", "x": 38.66014117583918, "y": -122.43986982074505, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5584edfb-c31e-4e1d-87d3-b8161a59b15b", "name": "p1rdt8904-p1rdt8916x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1df05fd9-2ce1-423d-a9c2-c03c77b85391"}}}}, {"uuid": "822ecf5e-9bf8-48d7-ae80-9241a08d5eef", "name": "", "x": 38.659870600443035, "y": -122.43853470846769, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2edd17c2-6dfb-4f86-8998-b90a99755e96", "name": "p1rdt8904", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "822ecf5e-9bf8-48d7-ae80-9241a08d5eef"}}}}, {"uuid": "cfdaa503-512b-4f4b-b7d2-25964bd60174", "name": "", "x": 38.66173047874001, "y": -122.44241135887862, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "361385c6-bb6d-4bbc-ab7d-4a5774e03d82", "name": "p1rdt8915", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cfdaa503-512b-4f4b-b7d2-25964bd60174"}}}}, {"uuid": "e09dc659-3e15-4f79-91c9-b52d623601ea", "name": "", "x": 38.66056980039024, "y": -122.44983541740483, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25a9ec20-35b9-4262-a02d-cafa63e5ee42", "name": "p1rdt6574", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e09dc659-3e15-4f79-91c9-b52d623601ea"}}}}, {"uuid": "17b20f9d-2e67-45af-a1f1-f14bdf5b6629", "name": "", "x": 38.66134287929267, "y": -122.44811296163041, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c9ef9958-5d9e-4907-91cd-4c5d099daaf1", "name": "p1rdt6574-p1rdt8915x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "17b20f9d-2e67-45af-a1f1-f14bdf5b6629"}}}}, {"uuid": "c909eedd-a3ad-4f87-a346-40647f90f3ca", "name": "", "x": 38.65937095205677, "y": -122.45169503023163, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "599c6ed9-5ff7-4c97-a469-adceecaaf902", "name": "p1rdt6581", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c909eedd-a3ad-4f87-a346-40647f90f3ca"}}}}, {"uuid": "169793d1-b20d-4e43-a918-a31b39feffe4", "name": "", "x": 38.658524104486, "y": -122.45387735426675, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6114624f-81c8-4d9c-8f9a-3ab73158596e", "name": "p1rdt6581-p1rdt9084x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "169793d1-b20d-4e43-a918-a31b39feffe4"}}}}, {"uuid": "32d60b45-d56c-403d-99e5-72dbc6f6ee64", "name": "", "x": 38.65932938830671, "y": -122.45365277312096, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b2ce5116-c4f0-4ac7-a34f-3ba44c99d04b", "name": "p1rdt9076", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "32d60b45-d56c-403d-99e5-72dbc6f6ee64"}}}}, {"uuid": "ed78c300-b738-4256-82ac-69932d19430e", "name": "", "x": 38.6598966989538, "y": -122.45427706074868, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c29179f3-0b4e-449c-8562-a8fcb675be6c", "name": "p1rdt9093", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ed78c300-b738-4256-82ac-69932d19430e"}}}}, {"uuid": "67e13266-9238-4cad-9947-2673df4847a6", "name": "", "x": 38.658584295641674, "y": -122.4538145255183, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "12b4dc99-fe50-457c-90aa-48a2fb19ebf1", "name": "p1rdt9076-p1rdt9084x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "67e13266-9238-4cad-9947-2673df4847a6"}}}}, {"uuid": "783adc37-8f14-4fc0-9882-7ff2167cccc1", "name": "", "x": 38.65080476587911, "y": -122.46154361413883, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "563c6bb3-d8ed-4fce-ad66-3892426248df", "name": "p1rdt9091", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "783adc37-8f14-4fc0-9882-7ff2167cccc1"}}}}, {"uuid": "f8ebc8aa-10ca-4c4b-a76e-7b55f47da7af", "name": "", "x": 38.65078478496911, "y": -122.46111855767518, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7fcdf409-885c-4c95-834e-988842ed3f5c", "name": "p1rdt9085", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f8ebc8aa-10ca-4c4b-a76e-7b55f47da7af"}}}}, {"uuid": "20bb0b23-1255-4362-8a41-c2cb5865a639", "name": "", "x": 38.6513283597693, "y": -122.46332611842509, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf719d10-8168-4d80-894e-1b1516f033e8", "name": "p1rdt9090-p1rdt9091x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "20bb0b23-1255-4362-8a41-c2cb5865a639"}}}}, {"uuid": "9969e473-9935-40da-9183-2c6da735131b", "name": "", "x": 38.64979039983577, "y": -122.4656039969192, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a5f6a2ec-3ddd-4ba7-9c55-88b4d82e7735", "name": "p1rdt9469-p1rdt9470x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9969e473-9935-40da-9183-2c6da735131b"}}}}, {"uuid": "6263920c-9fc3-4b2e-a546-abbddd42605f", "name": "", "x": 38.65049921056124, "y": -122.46639198488886, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "acf91e46-ba32-44c3-a829-14c80a693d7d", "name": "p1rdt9470", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6263920c-9fc3-4b2e-a546-abbddd42605f"}}}}, {"uuid": "0a73ebe0-b63d-458f-a694-bef5e5e35908", "name": "", "x": 38.62473134403656, "y": -122.446341336382, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "431b672b-cb45-4294-b1f9-1d63f4efc8db", "name": "p1rdt5184", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a73ebe0-b63d-458f-a694-bef5e5e35908"}}}}, {"uuid": "40171f66-03ca-44d5-a7d9-dd81cd1d77d0", "name": "", "x": 38.62489829777773, "y": -122.44603739457851, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ceb58d66-3cb3-416d-aedf-f4949432eb37", "name": "p1rdt5140-p1rdt5184x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "40171f66-03ca-44d5-a7d9-dd81cd1d77d0"}}}}, {"uuid": "3c7c92ef-f3c4-4b07-a237-27029a3a135b", "name": "", "x": 38.625549640330384, "y": -122.44525871373254, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4b0fd055-d0ac-4678-a8e5-679e12741736", "name": "p1rdt5140", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3c7c92ef-f3c4-4b07-a237-27029a3a135b"}}}}, {"uuid": "ad9b4b7a-0931-459e-98b2-2be8e2026ce0", "name": "", "x": 38.62488841554401, "y": -122.44776290196933, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "50332aed-ecfd-465a-977e-c24ed6462860", "name": "p1rdt5154", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ad9b4b7a-0931-459e-98b2-2be8e2026ce0"}}}}, {"uuid": "8e9f56d8-7fca-4f4e-ae86-e65be9cb8c4f", "name": "", "x": 38.62229054802191, "y": -122.44975245942024, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d579047b-82f6-49bf-bd7b-28c818d44bb3", "name": "p1rdt5142", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8e9f56d8-7fca-4f4e-ae86-e65be9cb8c4f"}}}}, {"uuid": "d8684006-5b25-49fb-a434-cfc2f1c5dec1", "name": "", "x": 38.62220258438888, "y": -122.44622230651564, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c6316fa2-dd57-46d4-89c0-f11dd675d686", "name": "p1rdt5180", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d8684006-5b25-49fb-a434-cfc2f1c5dec1"}}}}, {"uuid": "0c16fccb-d717-44aa-9f38-45a6246e6956", "name": "", "x": 38.62380545487311, "y": -122.4562212466049, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b48f78d-1092-4536-bfb3-029da6a70dff", "name": "p1rdt8414", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0c16fccb-d717-44aa-9f38-45a6246e6956"}}}}, {"uuid": "1c64bcc6-45c2-4d20-8bf9-0e11de4c7265", "name": "", "x": 38.623626833691524, "y": -122.455467102224, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "50f71b3d-83ce-4526-8057-4a38042b7295", "name": "p1rdt5142-p1rdt8414x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1c64bcc6-45c2-4d20-8bf9-0e11de4c7265"}}}}, {"uuid": "0b35d36d-70fc-40d5-914c-1a06b686e5a9", "name": "", "x": 38.62564005248976, "y": -122.46602311753331, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "42929633-40d4-4e13-a0aa-a7682f328226", "name": "p1rdt6409", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0b35d36d-70fc-40d5-914c-1a06b686e5a9"}}}}, {"uuid": "319a6f16-24d3-4b77-b1e8-7f7402459352", "name": "", "x": 38.62467409594971, "y": -122.4578141983919, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c8648275-54c9-48e3-82e0-33119313924d", "name": "p1rdt6409-p1rdt8414x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "319a6f16-24d3-4b77-b1e8-7f7402459352"}}}}, {"uuid": "1e5d5efe-22c3-4d18-9fba-2f30ab355a68", "name": "", "x": 38.62028911584838, "y": -122.47934854754749, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f750e531-5ade-40a9-9bb0-042220ce9807", "name": "p1rdt9413", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1e5d5efe-22c3-4d18-9fba-2f30ab355a68"}}}}, {"uuid": "c9ef1203-c178-47da-b18f-e0dc8a149ce5", "name": "", "x": 38.607806368453346, "y": -122.45767322666612, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f9b94106-b7c5-4ce9-9c19-053487848c2a", "name": "p1rdt7570", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c9ef1203-c178-47da-b18f-e0dc8a149ce5"}}}}, {"uuid": "1ea6e363-b354-4950-a115-36df79ac7e00", "name": "", "x": 38.60650861543276, "y": -122.45746126944624, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fd487832-bc77-406f-a995-4b099fad7c64", "name": "p1rdt7574", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1ea6e363-b354-4950-a115-36df79ac7e00"}}}}, {"uuid": "a90235cd-9b37-4856-b9de-bb34434bd0c2", "name": "", "x": 38.61094163932077, "y": -122.45877502518786, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "08d4c459-5bc5-4cad-8e74-613c4a08cb35", "name": "p1rdt6275", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a90235cd-9b37-4856-b9de-bb34434bd0c2"}}}}, {"uuid": "2d935bfb-e43c-45ee-b5df-0d97d91514f4", "name": "", "x": 38.6129133935745, "y": -122.45941441983003, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3cf36152-b3af-49f7-b693-5d465db1f283", "name": "p1rdt6270", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2d935bfb-e43c-45ee-b5df-0d97d91514f4"}}}}, {"uuid": "dfb10ac3-d01d-4ffb-a16b-d27afac7c0cb", "name": "", "x": 38.61549898247823, "y": -122.4595395605965, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b5ef97a6-6c60-46eb-acce-6469b273658a", "name": "p1rdt6269", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dfb10ac3-d01d-4ffb-a16b-d27afac7c0cb"}}}}, {"uuid": "7ef54c91-36ce-43c7-8b71-0385b3d8dc94", "name": "", "x": 38.617305618456946, "y": -122.4643619588085, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60829dab-c129-4017-961a-81435d8afa93", "name": "p1rdt8405", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7ef54c91-36ce-43c7-8b71-0385b3d8dc94"}}}}, {"uuid": "f73d9123-c351-479d-ba0d-bfd88fcaeac1", "name": "", "x": 38.62031463672319, "y": -122.47930548988975, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16ecb938-cd0c-4be5-a915-be0d84d351f2", "name": "p1rdt8405-p1rdt9413x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f73d9123-c351-479d-ba0d-bfd88fcaeac1"}}}}, {"uuid": "1031a2c7-4eb4-4229-8c5a-3ba72e4b2638", "name": "", "x": 38.574957799581, "y": -122.51876395636346, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d25f8d60-8aa7-4975-96dc-eba7696fa8ae", "name": "p1rdt9314", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1031a2c7-4eb4-4229-8c5a-3ba72e4b2638"}}}}, {"uuid": "43aaaf9a-7585-41cb-8661-2358b2f561e5", "name": "", "x": 38.57551466426878, "y": -122.51886483712937, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d39c608-5688-4e22-8ac4-96b896265274", "name": "p1rdt6518", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "43aaaf9a-7585-41cb-8661-2358b2f561e5"}}}}, {"uuid": "31845f68-2f99-480e-95bc-602b2a660cb5", "name": "", "x": 38.57472269246426, "y": -122.51786257188046, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d9b006c3-79f8-4a27-b76a-d1b458ff2a21", "name": "p1rdt9479", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "31845f68-2f99-480e-95bc-602b2a660cb5"}}}}, {"uuid": "635efc5b-e76d-40a8-b026-2e8350de069e", "name": "", "x": 38.57508507780314, "y": -122.51765748560604, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9707f264-8f82-4483-8337-6c89d709faf7", "name": "p1rdt6539", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "635efc5b-e76d-40a8-b026-2e8350de069e"}}}}, {"uuid": "d5df494f-b6e9-4370-9ff0-795e3592612e", "name": "", "x": 38.575354576929136, "y": -122.51744904257968, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0db3e719-4dba-4b45-af70-c35546c19eb4", "name": "p1rdt6507", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d5df494f-b6e9-4370-9ff0-795e3592612e"}}}}, {"uuid": "6f46c81f-1ceb-4611-9652-4535d88f4fc6", "name": "", "x": 38.577519567449535, "y": -122.51578138154942, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "40ec7437-80f0-49e8-806a-c696b1402713", "name": "p1rdt6530", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6f46c81f-1ceb-4611-9652-4535d88f4fc6"}}}}, {"uuid": "33e0291b-9d5f-4928-95dc-45d472013d5d", "name": "", "x": 38.57798706705615, "y": -122.51470262020904, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b56340a0-81f0-4028-9283-532f0d92a412", "name": "p1rdt6517", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "33e0291b-9d5f-4928-95dc-45d472013d5d"}}}}, {"uuid": "f4d81409-19b9-4e42-a06c-3ce62f8ab4f9", "name": "", "x": 38.579746916502536, "y": -122.51263999956761, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "608945f2-9b19-43bc-83d9-0fe8787b06b4", "name": "p1rdt6517-p1rdt6523x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f4d81409-19b9-4e42-a06c-3ce62f8ab4f9"}}}}, {"uuid": "07f3008d-00cd-4df8-8bea-83653784bac1", "name": "", "x": 38.58000496177514, "y": -122.51234696117584, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "24028ccd-3fd3-4461-b83c-54266f91a385", "name": "p1rdt6520", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "07f3008d-00cd-4df8-8bea-83653784bac1"}}}}, {"uuid": "e3fa98f5-3d51-4345-84df-74893d453208", "name": "", "x": 38.57971971243869, "y": -122.51259440779317, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b540c710-395d-4a35-8dc3-59d37609df09", "name": "p1rdt6523", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e3fa98f5-3d51-4345-84df-74893d453208"}}}}, {"uuid": "515c2487-0a37-42d4-9ec4-2f5d75840d25", "name": "", "x": 38.58012887408336, "y": -122.51206038960157, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "99fa55d1-867c-4db0-8697-b532da10d6d4", "name": "p1rdt6501", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "515c2487-0a37-42d4-9ec4-2f5d75840d25"}}}}, {"uuid": "582e1fdd-0784-4e10-9065-38231440dc00", "name": "", "x": 38.580187053973766, "y": -122.51175395124783, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "89434ebc-1e79-4414-9925-1a14f8e72fd6", "name": "p1rdt6499", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "582e1fdd-0784-4e10-9065-38231440dc00"}}}}, {"uuid": "e50403c5-4866-4194-bb01-be0e09fa1377", "name": "", "x": 38.580244659409736, "y": -122.51143788792888, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e67c889f-e940-4242-9c83-4b5ab673d8a8", "name": "p1rdt6509", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e50403c5-4866-4194-bb01-be0e09fa1377"}}}}, {"uuid": "e659b9f0-3f1e-4b24-ab87-a5123dd51b1c", "name": "", "x": 38.58030980831637, "y": -122.51115038887805, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e165d0d-3f13-4d87-9c4b-fdfa8829f1f3", "name": "p1rdt6508", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e659b9f0-3f1e-4b24-ab87-a5123dd51b1c"}}}}, {"uuid": "b615cc6e-c30f-4996-882a-a05a0058354e", "name": "", "x": 38.580354920781474, "y": -122.5109491558155, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "302d2adf-2199-47b2-9f3c-e428bb409b6f", "name": "p1rdt6521", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b615cc6e-c30f-4996-882a-a05a0058354e"}}}}, {"uuid": "46ab54f2-6e29-4b41-b41f-06337d4964f7", "name": "", "x": 38.58042615056892, "y": -122.51074201742463, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6f7572ed-6443-4e6e-8fb8-0b060b9f17ce", "name": "p1rdt6512", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "46ab54f2-6e29-4b41-b41f-06337d4964f7"}}}}, {"uuid": "3b809375-b5a2-4775-a0b9-2676d6fda7d7", "name": "", "x": 38.58053498950995, "y": -122.5103355002012, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1ef8c502-c06f-43e5-90e6-23bd0ebcf155", "name": "p1rdt6524", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3b809375-b5a2-4775-a0b9-2676d6fda7d7"}}}}, {"uuid": "d69f12ba-021d-452d-bb69-d958c3a8cb16", "name": "", "x": 38.56382999437341, "y": -122.50863846453362, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6372a592-5e2d-41c8-819b-f56bfbb58e19", "name": "p1rdt7091", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d69f12ba-021d-452d-bb69-d958c3a8cb16"}}}}, {"uuid": "69d63238-38a7-42a0-8a20-6c9477697ccb", "name": "", "x": 38.5636996056699, "y": -122.50885698702933, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2324afa4-5274-4392-9a0e-be8dc2bebeba", "name": "p1rdt7091-p1rdt7625x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "69d63238-38a7-42a0-8a20-6c9477697ccb"}}}}, {"uuid": "37c17271-1d66-4530-babf-ba7c9bb6114e", "name": "", "x": 38.56314359789373, "y": -122.50948068684706, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3e6cbe9-d1d3-4c59-981f-dad980f0999b", "name": "p1rdt7625", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "37c17271-1d66-4530-babf-ba7c9bb6114e"}}}}, {"uuid": "dbff52e8-5b75-4845-8a22-7f8073c4f4bc", "name": "", "x": 38.56813752425825, "y": -122.50551166975698, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0cf1844f-a32e-40f2-bc96-05fad3bdd88d", "name": "p1rdt7314", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dbff52e8-5b75-4845-8a22-7f8073c4f4bc"}}}}, {"uuid": "bda52bf5-41bc-46b2-9c3d-66ebc4d33d9b", "name": "", "x": 38.56852875024663, "y": -122.50519721502558, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e86bc267-1607-4aa3-916f-ed826b0adfdc", "name": "p1rdt7318", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bda52bf5-41bc-46b2-9c3d-66ebc4d33d9b"}}}}, {"uuid": "f6353f32-6099-411d-a61a-5f3301e972e7", "name": "", "x": 38.57391341112913, "y": -122.50681689306278, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "231b5cf9-ec2c-47d1-aada-5454926561dd", "name": "p1rdt7307", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f6353f32-6099-411d-a61a-5f3301e972e7"}}}}, {"uuid": "17d081fe-5198-48d6-90b7-5bfaead55094", "name": "", "x": 38.57883713707986, "y": -122.51041811805065, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8431ef4c-78dd-4a39-b15a-95818cfe1d86", "name": "p1rdt6531-p1rdt7307x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "17d081fe-5198-48d6-90b7-5bfaead55094"}}}}, {"uuid": "1a2eb0e7-c58b-47f3-9b0b-89750d713fe9", "name": "", "x": 38.57902238646377, "y": -122.51037187678122, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "483b2d65-b496-4c6f-b01d-66aa3d9d4334", "name": "p1rdt6527", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1a2eb0e7-c58b-47f3-9b0b-89750d713fe9"}}}}, {"uuid": "353fee29-202d-4129-a38e-30d19f45d48a", "name": "", "x": 38.57879504932116, "y": -122.51042237415348, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "385eabe4-8c8e-4354-96ec-931e6c25574d", "name": "p1rdt6531", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "353fee29-202d-4129-a38e-30d19f45d48a"}}}}, {"uuid": "9feadd92-cb06-4c71-af76-75d239af08d9", "name": "", "x": 38.57912969611421, "y": -122.51047132869749, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5bd908fd-8bb8-42c1-8d1b-27c4e2574450", "name": "p1rdt6516", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9feadd92-cb06-4c71-af76-75d239af08d9"}}}}, {"uuid": "f6082925-7139-4fd8-aabe-610e992c29c1", "name": "", "x": 38.57925217424879, "y": -122.51051911433764, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6191a237-532b-44e2-86a8-d9ed56b914b5", "name": "p1rdt6516-p1rdt6524x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f6082925-7139-4fd8-aabe-610e992c29c1"}}}}, {"uuid": "fea2501d-3188-46ea-999f-cd8c413e6241", "name": "", "x": 38.580795923241645, "y": -122.50969387468216, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6a3d9ed9-e2e4-4332-89a2-358441869830", "name": "p1rdt6500-p1rdt6524x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fea2501d-3188-46ea-999f-cd8c413e6241"}}}}, {"uuid": "033688ee-3963-47a5-b30e-240a541604b3", "name": "", "x": 38.58050902502442, "y": -122.51029289847199, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "97b7ef3c-ef16-4c4d-8559-722c5c67749a", "name": "p1rdt6500-p1rdt6524xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "033688ee-3963-47a5-b30e-240a541604b3"}}}}, {"uuid": "5dac2af1-c479-42f6-95d6-e100063c675f", "name": "", "x": 38.58110574867303, "y": -122.50932633681218, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "18b822d0-cbe4-48d7-a818-87e25412d241", "name": "p1rdt6500-p1rdt6515xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5dac2af1-c479-42f6-95d6-e100063c675f"}}}}, {"uuid": "e564fdf3-ba34-4758-b781-3ed6d147914d", "name": "", "x": 38.58088888848231, "y": -122.50970513801667, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0043b26d-8a33-4e32-a963-c4638f943775", "name": "p1rdt6500-p1rdt6515x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e564fdf3-ba34-4758-b781-3ed6d147914d"}}}}, {"uuid": "e0de6dd3-0811-4bf9-a6ab-34bca44c5080", "name": "", "x": 38.58110455057315, "y": -122.5093365351204, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "04c3a970-215a-4e16-a798-80496ffad438", "name": "p1rdt6515-p1rdt6528xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e0de6dd3-0811-4bf9-a6ab-34bca44c5080"}}}}, {"uuid": "cf445906-c1c3-4e18-86a9-61dd94fab3a3", "name": "", "x": 38.58101245616958, "y": -122.50933552593602, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8dcd059f-292b-4f7a-96c1-a3dc185f1eec", "name": "p1rdt6515-p1rdt6528x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cf445906-c1c3-4e18-86a9-61dd94fab3a3"}}}}, {"uuid": "003fd690-4612-4698-bd6f-501feea117d2", "name": "", "x": 38.58147116472299, "y": -122.50902570371277, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "918984ec-3b5f-4174-9bca-771bb10e0f60", "name": "p1rdt6528-p1rdt8898xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "003fd690-4612-4698-bd6f-501feea117d2"}}}}, {"uuid": "0753826c-0c48-45ad-856a-f3ea5b33be40", "name": "", "x": 38.5810944181135, "y": -122.50923796161061, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0156ae64-03dc-4ec0-89c8-8b09a6fc9090", "name": "p1rdt6528-p1rdt8898x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0753826c-0c48-45ad-856a-f3ea5b33be40"}}}}, {"uuid": "fb1daff8-5e70-4d5f-80eb-6a7f365b58e0", "name": "", "x": 38.581587918670415, "y": -122.50894214477799, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b51e96e7-2d7f-42af-9115-c9b1cfb3131c", "name": "p1rdt6532-p1rdt8898x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fb1daff8-5e70-4d5f-80eb-6a7f365b58e0"}}}}, {"uuid": "26aa73db-5454-4f33-ba1b-b5e77e453ecf", "name": "", "x": 38.5813985191289, "y": -122.5089902200945, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "af1707bf-0b2e-4f76-96e7-c01338300d45", "name": "p1rdt6532-p1rdt8898xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "26aa73db-5454-4f33-ba1b-b5e77e453ecf"}}}}, {"uuid": "3573d3c0-5f83-4628-8077-f75cd6245d5b", "name": "", "x": 38.581811295389215, "y": -122.50861649779817, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e4a0469e-1a4a-466d-b18d-f3017b6415ae", "name": "p1rdt6532-p1rdt8902xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3573d3c0-5f83-4628-8077-f75cd6245d5b"}}}}, {"uuid": "311042de-27e1-40a3-87b6-e39cf7548d48", "name": "", "x": 38.581516114078376, "y": -122.50890397337818, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4f373554-9d8a-4a9c-b418-25e67fbb43a9", "name": "p1rdt6532-p1rdt8902x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "311042de-27e1-40a3-87b6-e39cf7548d48"}}}}, {"uuid": "c8f27702-2cc7-4484-93fd-58e51c0fb16e", "name": "", "x": 38.58365359761406, "y": -122.50734451106864, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "68b101ef-d71a-44d2-b1c2-4fc5e9f62499", "name": "p1rdt6052-p1rdt8902x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c8f27702-2cc7-4484-93fd-58e51c0fb16e"}}}}, {"uuid": "a9c3cd5e-cc7b-414b-b943-114ee1ba9f67", "name": "", "x": 38.58185095473939, "y": -122.50866687243757, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "468b1ce8-18fa-423b-99ca-1f3784437721", "name": "p1rdt6052-p1rdt8902xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a9c3cd5e-cc7b-414b-b943-114ee1ba9f67"}}}}, {"uuid": "b27f0dc4-65b4-473e-abdb-c08955bb9f83", "name": "", "x": 38.58373478464309, "y": -122.50725547084005, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "99e2ec8b-60fc-4a79-9eed-0d617babcb1d", "name": "p1rdt6046-p1rdt6052x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b27f0dc4-65b4-473e-abdb-c08955bb9f83"}}}}, {"uuid": "bc30bfc5-b613-42c4-8648-b0da774761d0", "name": "", "x": 38.583726243675486, "y": -122.5073799941088, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "49c69b43-f43b-4576-bbfa-d06b1d27de95", "name": "p1rdt6046-p1rdt6052xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bc30bfc5-b613-42c4-8648-b0da774761d0"}}}}, {"uuid": "fd4305f4-813c-4155-9c8f-cc87a063a114", "name": "", "x": 38.583771567152084, "y": -122.5072620145205, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be3d7f84-84e7-46fc-a9ce-b3e0cf74d1d3", "name": "p1rdt6043-p1rdt6046x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fd4305f4-813c-4155-9c8f-cc87a063a114"}}}}, {"uuid": "65e729c9-72ca-4616-b134-969f2edf5e19", "name": "", "x": 38.583673113710276, "y": -122.507315876951, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a147dd91-5597-40ff-93f9-0522ad3c726c", "name": "p1rdt6043-p1rdt6046xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65e729c9-72ca-4616-b134-969f2edf5e19"}}}}, {"uuid": "78471c56-df6e-47cb-97a4-ec628ff465c4", "name": "", "x": 38.583737845666946, "y": -122.50660841152015, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6f01bba4-b8e8-45ed-af3b-1ac5a287ad46", "name": "p1rdt6043-p1rdt6045xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "78471c56-df6e-47cb-97a4-ec628ff465c4"}}}}, {"uuid": "5dd9ba6c-e61b-463f-a515-95b3ddfd6abd", "name": "", "x": 38.58376143292759, "y": -122.50716343767925, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48d6768a-45e6-48a5-b22d-d5d418cb6221", "name": "p1rdt6043-p1rdt6045x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5dd9ba6c-e61b-463f-a515-95b3ddfd6abd"}}}}, {"uuid": "fcc2a891-40fa-4b5c-bdd9-244cef4e93a7", "name": "", "x": 38.584313677622774, "y": -122.50614079151774, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "34a9d21e-bcf7-4266-9834-60a72878ddd4", "name": "p1rdt6047", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fcc2a891-40fa-4b5c-bdd9-244cef4e93a7"}}}}, {"uuid": "e939a1b6-cedc-4d65-858d-686681519111", "name": "", "x": 38.58376381148312, "y": -122.50665101380328, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0396342e-2dc8-4a01-9da9-513953f9b5fa", "name": "p1rdt6045", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e939a1b6-cedc-4d65-858d-686681519111"}}}}, {"uuid": "b1e530e0-7893-4451-964c-130b7125f7f1", "name": "", "x": 38.58637708588061, "y": -122.50393363509188, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f8898950-d712-40dc-99b5-33882b96b225", "name": "p1rdt6038", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b1e530e0-7893-4451-964c-130b7125f7f1"}}}}, {"uuid": "da6f6b5b-8559-41f7-af03-efce97dc18cd", "name": "", "x": 38.59928901894631, "y": -122.48316671744382, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a086b782-3a8d-44e9-9948-cb7f051219e3", "name": "p1rdt7599", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "da6f6b5b-8559-41f7-af03-efce97dc18cd"}}}}, {"uuid": "609ac35d-fcd1-4ca4-ac26-5508b44e4ee4", "name": "", "x": 38.58770893471679, "y": -122.5028146867888, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3cfe89e9-a7a8-456d-966b-67429017f456", "name": "p1rdt6038-p1rdt7599x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "609ac35d-fcd1-4ca4-ac26-5508b44e4ee4"}}}}, {"uuid": "9b4fde9b-7944-467b-a9f5-52d268a644ee", "name": "", "x": 38.600060944468346, "y": -122.4812911472599, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0809ec5e-d36f-4bea-91b3-962ad6c29606", "name": "p1rdt6221", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9b4fde9b-7944-467b-a9f5-52d268a644ee"}}}}, {"uuid": "24852869-a1c5-4db0-95e5-c320b2bdc195", "name": "", "x": 38.60505176311642, "y": -122.47599334604853, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cdfc617f-fbfb-4e9a-862e-cd5a296748cb", "name": "p1rdt6208", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "24852869-a1c5-4db0-95e5-c320b2bdc195"}}}}, {"uuid": "d3816b74-5540-46d7-bb85-811d4c985b35", "name": "", "x": 38.60037508320662, "y": -122.48099954218519, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e1a5a109-eee6-46be-be53-3fbe4a406575", "name": "p1rdt6208-p1rdt6221x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d3816b74-5540-46d7-bb85-811d4c985b35"}}}}, {"uuid": "09ec30ea-572f-4201-ab0e-bcaa5f62e366", "name": "", "x": 38.60815051684694, "y": -122.4765469245405, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "89f0c671-9d27-4dec-bd37-dc6c56f07e5d", "name": "p1rdt6208-p1rdt8805x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "09ec30ea-572f-4201-ab0e-bcaa5f62e366"}}}}, {"uuid": "af24f76a-b2a7-4be6-998a-9c8b47186469", "name": "", "x": 38.57279151417879, "y": -122.49288162437385, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "17e89212-bc51-4fc2-83d1-4c74a285be23", "name": "p1rdt5662", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "af24f76a-b2a7-4be6-998a-9c8b47186469"}}}}, {"uuid": "9223305e-a3da-4bbd-ada6-4a46ca8d1722", "name": "", "x": 38.57272640832975, "y": -122.49539881317247, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6f2bb66-d966-4228-8a13-96c57e8fbfba", "name": "p1rdt5656-p1rdt5662x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9223305e-a3da-4bbd-ada6-4a46ca8d1722"}}}}, {"uuid": "82ef4fd2-7195-44ec-84b9-64fa3ab7a3f0", "name": "", "x": 38.57265915120934, "y": -122.49564074606137, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f417a58d-5a47-4310-bac6-e8bb95fffc19", "name": "p1rdt5656", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "82ef4fd2-7195-44ec-84b9-64fa3ab7a3f0"}}}}, {"uuid": "4a9b2caa-f848-47c9-a059-957fa52f8f06", "name": "", "x": 38.58485209359688, "y": -122.4751287858777, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "23f0bb81-3c30-45a5-89ca-2011e3881ddb", "name": "p1rdt5183", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4a9b2caa-f848-47c9-a059-957fa52f8f06"}}}}, {"uuid": "b270cdf3-cf3c-4029-a234-1c61167c5fda", "name": "", "x": 38.57451035345935, "y": -122.49113876914703, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a05b2959-a8dd-417b-b566-8f84384a3559", "name": "p1rdt5183-p1rdt5662x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b270cdf3-cf3c-4029-a234-1c61167c5fda"}}}}, {"uuid": "2a0c5a2b-f586-42b2-8ffd-fe3202072fa0", "name": "", "x": 38.58726329125732, "y": -122.47503377407112, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35487e15-57cb-4e19-bef7-49074e5eb9ee", "name": "p1rdt4980-p1rdt5183x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2a0c5a2b-f586-42b2-8ffd-fe3202072fa0"}}}}, {"uuid": "d21b0e02-57ba-4706-b64c-bf0090e0ea77", "name": "", "x": 38.588776084576374, "y": -122.47343214290899, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6c09f718-9379-4281-86f6-55c46e46aec6", "name": "p1rdt5017", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d21b0e02-57ba-4706-b64c-bf0090e0ea77"}}}}, {"uuid": "156e698e-e740-43b4-a724-4c7512ab895f", "name": "", "x": 38.58727709580159, "y": -122.47498276916237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6ddb0629-4947-47ca-83f9-9b7c073db235", "name": "p1rdt4980", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "156e698e-e740-43b4-a724-4c7512ab895f"}}}}, {"uuid": "ddb76e34-841b-49c0-b867-d88bea22d92a", "name": "", "x": 38.58932620721099, "y": -122.47402937641733, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f7f13598-e628-457c-9ba6-d9a0123e882c", "name": "p1rdt4964", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ddb76e34-841b-49c0-b867-d88bea22d92a"}}}}, {"uuid": "22773cea-500b-4798-8aa4-1df98c90efb3", "name": "", "x": 38.58925865771824, "y": -122.47388020936008, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf1c765f-ca54-48cf-806f-6a1b5719c4b0", "name": "p1rdt4964-p1rdt5017x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "22773cea-500b-4798-8aa4-1df98c90efb3"}}}}, {"uuid": "ab497915-2f5e-4f84-afff-5092914cbc85", "name": "", "x": 38.599541593142376, "y": -122.47111831101633, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "42ab6054-1866-49c5-b2ab-3cf27199c1c8", "name": "p1rdt8154", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ab497915-2f5e-4f84-afff-5092914cbc85"}}}}, {"uuid": "6f44f73f-9fc9-4ff0-b2a7-29b6a0732165", "name": "", "x": 38.59202547989681, "y": -122.47391743009182, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fb1e0d86-907d-4564-a90e-c1400917d3ca", "name": "p1rdt4964-p1rdt8154x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6f44f73f-9fc9-4ff0-b2a7-29b6a0732165"}}}}, {"uuid": "ae7ca9ea-21fa-4d1d-81bd-d01623b8672e", "name": "", "x": 38.599346582191174, "y": -122.4698450346779, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b44d5021-4fdb-4618-bcb2-237ecf2e10e4", "name": "p1rdt8153", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ae7ca9ea-21fa-4d1d-81bd-d01623b8672e"}}}}, {"uuid": "da4c3120-9386-4ac0-a965-1d368dc4eb77", "name": "", "x": 38.59932444954078, "y": -122.4697759036714, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "40962258-28d3-4406-9e9e-121f373cce25", "name": "p1rdt8151-p1rdt8153x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "da4c3120-9386-4ac0-a965-1d368dc4eb77"}}}}, {"uuid": "a605e89a-2a49-4fb3-a6a6-235d6b52275e", "name": "", "x": 38.599762625990174, "y": -122.46808190408947, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6c794942-d5ce-481f-9c6a-563a2180a4ba", "name": "p1rdt8151", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a605e89a-2a49-4fb3-a6a6-235d6b52275e"}}}}, {"uuid": "cb85fe25-d34d-4660-90eb-26a04f0f26af", "name": "", "x": 38.605132002398605, "y": -122.47349749138557, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0da91bf8-b687-47df-a7dc-41e6166fd667", "name": "p1rdt9333", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb85fe25-d34d-4660-90eb-26a04f0f26af"}}}}, {"uuid": "5bf299c2-dd95-465a-bd1c-6550b9c7ecd1", "name": "", "x": 38.60218088899386, "y": -122.47169573381588, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0aef77ef-aaaa-4a6e-90ef-87348baaf1a0", "name": "p1rdt8154-p1rdt9333x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5bf299c2-dd95-465a-bd1c-6550b9c7ecd1"}}}}, {"uuid": "7ed57c9a-f3a4-432d-931f-5fcbd8226827", "name": "", "x": 38.608136170076634, "y": -122.47649614861295, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3444af6b-f9d4-4229-b6b2-2114300c3f94", "name": "p1rdt8805", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7ed57c9a-f3a4-432d-931f-5fcbd8226827"}}}}, {"uuid": "9361e3c5-5508-49d1-8324-50197f15d00b", "name": "", "x": 38.609815768546184, "y": -122.4765312522036, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "26ccaeff-3a34-4835-8906-1145148549c6", "name": "p1rdt8802", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9361e3c5-5508-49d1-8324-50197f15d00b"}}}}, {"uuid": "f2365584-be6c-4540-994c-e874243d629f", "name": "", "x": 38.609928396533334, "y": -122.47651694646427, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "401576cc-4ad6-42cd-bf1c-4022da720711", "name": "p1rdt8802-p1rdt9413xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f2365584-be6c-4540-994c-e874243d629f"}}}}, {"uuid": "f510224a-87d0-4a9f-8bfe-1825b789e2b8", "name": "", "x": 38.618837809141326, "y": -122.47838533286804, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e527bf48-b574-43bd-9a5d-484654dc76fe", "name": "p1rdt8802-p1rdt9413x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f510224a-87d0-4a9f-8bfe-1825b789e2b8"}}}}, {"uuid": "f194c891-16c9-4a51-b620-232d3a58f3c7", "name": "", "x": 38.62912673381444, "y": -122.48799793138168, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c0dafde2-c08e-4624-9212-e0fea9e47c2c", "name": "p1rdt5126", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f194c891-16c9-4a51-b620-232d3a58f3c7"}}}}, {"uuid": "93aa763a-d394-4fea-a89b-8ff3e9f2f138", "name": "", "x": 38.64192278671691, "y": -122.50364415036834, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4c8f9ea6-06fb-4fd0-8629-ceea4f32189f", "name": "p1rdt5342", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "93aa763a-d394-4fea-a89b-8ff3e9f2f138"}}}}, {"uuid": "e897b484-4f5d-4511-96ed-69f112c49f0c", "name": "", "x": 38.63755626056743, "y": -122.46589422645306, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7e240270-762d-49f0-a4e4-29fcd6273ce5", "name": "p1rdt7624", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e897b484-4f5d-4511-96ed-69f112c49f0c"}}}}, {"uuid": "0d2d5b6d-abe4-4eb9-ab07-26bdb36af719", "name": "", "x": 38.63942506778048, "y": -122.46168548768624, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b077dc9c-1c6f-4403-ae0c-954e7cc0c692", "name": "p1rdt5476", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0d2d5b6d-abe4-4eb9-ab07-26bdb36af719"}}}}, {"uuid": "148a4099-82af-42f4-b914-66cf29ec0d00", "name": "", "x": 38.643194242872035, "y": -122.47115740856567, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "42b9c576-ddba-4be1-bc64-a37d8cbdfa84", "name": "p1rdt8159", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "148a4099-82af-42f4-b914-66cf29ec0d00"}}}}, {"uuid": "91243721-ce14-4cc8-a69c-acbee3ff9fda", "name": "", "x": 38.64188879325188, "y": -122.47007141909909, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d1ab9716-b9f3-44e5-b9f6-cd83d0904dd3", "name": "p1rdt7624-p1rdt8159x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "91243721-ce14-4cc8-a69c-acbee3ff9fda"}}}}, {"uuid": "cff42dc3-ba94-4c55-a541-87283cc47044", "name": "", "x": 38.64458771393313, "y": -122.47217469285334, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25946c74-15c2-412c-baed-8de5f7aecf98", "name": "p1rdt8161", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cff42dc3-ba94-4c55-a541-87283cc47044"}}}}, {"uuid": "ced643af-8d28-41e7-81bc-9298c8c8a7c1", "name": "", "x": 38.64808407134208, "y": -122.45916844730037, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f31b09da-e4cc-409e-9634-1907480039ff", "name": "p1rdt7253", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ced643af-8d28-41e7-81bc-9298c8c8a7c1"}}}}, {"uuid": "9f7fd998-363e-47bc-a5ec-6acba95517ae", "name": "", "x": 38.64789780072754, "y": -122.44172571021984, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "442de065-9e2a-4ff8-9100-1298d3fe0f6f", "name": "p1rdt8470", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9f7fd998-363e-47bc-a5ec-6acba95517ae"}}}}, {"uuid": "33742eaa-2507-43f4-8e91-c5c625e02232", "name": "", "x": 38.648387196658014, "y": -122.46102160071564, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7a006c5f-e960-4ae2-a37f-d23d7b873a22", "name": "p1rdt7248", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "33742eaa-2507-43f4-8e91-c5c625e02232"}}}}, {"uuid": "7104919f-4adc-4a80-8457-659bf8f006bc", "name": "", "x": 38.64846046981178, "y": -122.46458969235934, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a2f1a631-48f7-4291-9adb-588a66620ebf", "name": "p1rdt7220", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7104919f-4adc-4a80-8457-659bf8f006bc"}}}}, {"uuid": "60ab8c09-8396-4f17-b6fd-aa407a787161", "name": "", "x": 38.64777195633766, "y": -122.46661554016796, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "38b72c12-2e2f-4d83-8f5a-9d8503dc29eb", "name": "p1rdt8160", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "60ab8c09-8396-4f17-b6fd-aa407a787161"}}}}, {"uuid": "11246cdc-f535-43ac-bc2f-283ef1067f9a", "name": "", "x": 38.655229305360514, "y": -122.45615922843626, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "907828f5-8e26-41c4-8fbc-a3744608181a", "name": "p1rdt9075", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "11246cdc-f535-43ac-bc2f-283ef1067f9a"}}}}, {"uuid": "e870ef83-64a3-438a-8029-6d8886b57301", "name": "", "x": 38.65752720541336, "y": -122.45501513442589, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c10b6848-6c57-4243-8cb9-ec28d0a4c9dd", "name": "p1rdt9075-p1rdt9084x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e870ef83-64a3-438a-8029-6d8886b57301"}}}}, {"uuid": "815040ca-6a4c-4405-8579-ff7a3f914bfc", "name": "", "x": 38.65853988991046, "y": -122.45382366130036, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4251587d-600f-40a0-9aec-229fb2e3f2df", "name": "p1rdt9084", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "815040ca-6a4c-4405-8579-ff7a3f914bfc"}}}}, {"uuid": "cd1cc0f4-b4ac-4522-bdd8-e3dc70594d6a", "name": "", "x": 38.652201124748096, "y": -122.4614412233577, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0b7f2f09-976a-45da-8186-229aeedeb689", "name": "p1rdt9077", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cd1cc0f4-b4ac-4522-bdd8-e3dc70594d6a"}}}}, {"uuid": "9d8b7eaa-852a-4c6d-b0c9-1b2426b9217a", "name": "", "x": 38.65243762839318, "y": -122.46214490936109, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1b4ec275-bea8-45f2-94cb-5e24e82179d8", "name": "p1rdt9089", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9d8b7eaa-852a-4c6d-b0c9-1b2426b9217a"}}}}, {"uuid": "0616daa6-3191-4406-9a69-d24e5f3a9dd4", "name": "", "x": 38.65135661168091, "y": -122.46337071841116, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "52c72b52-1c6c-46f6-adbe-1054eb233c20", "name": "p1rdt9090", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0616daa6-3191-4406-9a69-d24e5f3a9dd4"}}}}, {"uuid": "e4ace3e4-f86a-4403-840c-5233a8d47f89", "name": "", "x": 38.65237921170061, "y": -122.46231727928001, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e4d2db3-67c5-4fef-996a-5774803c89b1", "name": "p1rdt9089-p1rdt9090x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e4ace3e4-f86a-4403-840c-5233a8d47f89"}}}}, {"uuid": "f6b9afad-4208-4121-9829-dc64e012f791", "name": "", "x": 38.649831613431125, "y": -122.46561633896845, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3fd32c7-2866-4699-93a8-dd3a9997d349", "name": "p1rdt9469", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f6b9afad-4208-4121-9829-dc64e012f791"}}}}, {"uuid": "b4d949aa-8e70-4f2e-b001-812a6d42b686", "name": "", "x": 38.65039847441097, "y": -122.46468794326384, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "708803a5-3daf-4892-96e3-b182e2d214ec", "name": "p1rdt9090-p1rdt9469x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b4d949aa-8e70-4f2e-b001-812a6d42b686"}}}}, {"uuid": "ba7b18f7-6460-41e0-9b2b-3f9af5c9c69c", "name": "", "x": 38.64456173566906, "y": -122.4721320674015, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c8ecbd5b-6db5-44a0-b2a8-0233d4eb5b20", "name": "p1rdt8160-p1rdt8161xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ba7b18f7-6460-41e0-9b2b-3f9af5c9c69c"}}}}, {"uuid": "331f72b2-c8fa-4979-a0f4-6b7c8286c289", "name": "", "x": 38.645703216313166, "y": -122.47060639662344, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cc9cbaf2-05bd-49aa-bd14-a363d4970d0f", "name": "p1rdt8160-p1rdt8161x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "331f72b2-c8fa-4979-a0f4-6b7c8286c289"}}}}, {"uuid": "d7c8d0dd-b7e9-4606-b2ed-56da52b32e46", "name": "", "x": 38.641446776145905, "y": -122.48088775120242, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "22db53ea-6d9a-4527-9b36-34a4bcd2c74f", "name": "p1rdt5236", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d7c8d0dd-b7e9-4606-b2ed-56da52b32e46"}}}}, {"uuid": "f3e02c92-fbc6-412b-8ea3-c179fa8c1404", "name": "", "x": 38.64423596256915, "y": -122.47297284989183, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "67967bdd-155c-49fd-8d4c-29b40415a243", "name": "p1rdt5236-p1rdt8161x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f3e02c92-fbc6-412b-8ea3-c179fa8c1404"}}}}, {"uuid": "4ae6ae6c-48be-4637-a5e1-b25dc9fa53b0", "name": "", "x": 38.64189681984152, "y": -122.50360151499711, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9bbfae79-a578-4ff2-b622-3dddd9859ac8", "name": "p1rdt5236-p1rdt5342x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ae6ae6c-48be-4637-a5e1-b25dc9fa53b0"}}}}, {"uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac", "name": "", "limit_type": "min", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "base"}}, "value": {"value": 0.26327172275046934, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}}, {"uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b", "name": "", "limit_type": "max", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "base"}}, "value": {"value": 0.2909845356715714, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}}, {"uuid": "c506c458-594e-4c5f-9e1f-7e22db8220b6", "name": "", "x": 38.62487405627925, "y": -122.44771212016306, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9750085f-4afd-48ee-89f3-edbe9687b242", "name": "p1rdt5154lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c506c458-594e-4c5f-9e1f-7e22db8220b6"}}}}, {"uuid": "090a2c8f-a953-4cac-b416-8e61fbf2d4b4", "name": "", "x": 38.62484806916583, "y": -122.44766951523545, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "08331744-08b7-455e-b2ca-284cae95fb06", "name": "p1rlv10539", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "090a2c8f-a953-4cac-b416-8e61fbf2d4b4"}}}}, {"uuid": "80a16f1a-9fbf-462f-b254-04a16da0b948", "name": "", "x": 38.62592881156844, "y": -122.44183363220685, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7235cf3a-dd26-47f7-884c-6335024a3064", "name": "p1rdt7632lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "80a16f1a-9fbf-462f-b254-04a16da0b948"}}}}, {"uuid": "18196f08-5ffc-4531-9ce1-984f0bd06c0b", "name": "", "x": 38.62591502181451, "y": -122.4418846707521, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "606bf8f6-d745-4220-8cae-e01ffd22f669", "name": "p1rlv16271", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "18196f08-5ffc-4531-9ce1-984f0bd06c0b"}}}}, {"uuid": "4739b7b5-d6d6-4a0f-bdca-ee44962ae707", "name": "", "x": 38.6268422350558, "y": -122.44358917844923, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b336e76f-17f3-4f5d-ba84-f24c3a4e3eed", "name": "p1rdt9265", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4739b7b5-d6d6-4a0f-bdca-ee44962ae707"}}}}, {"uuid": "9eb2fe35-b2d7-4c73-bc6a-9b8f07206031", "name": "", "x": 38.62595431848947, "y": -122.4417905580223, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "36e7cd28-6795-41d5-847d-92347871384f", "name": "p1rdt7632", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9eb2fe35-b2d7-4c73-bc6a-9b8f07206031"}}}}, {"uuid": "525621bc-eb00-4748-9592-9b3796d898ad", "name": "", "x": 38.626761518561686, "y": -122.44366797538842, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60837f06-40cb-4f12-b36f-fe5e502c96d9", "name": "p1rdt5140-p1rdt9265x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "525621bc-eb00-4748-9592-9b3796d898ad"}}}}, {"uuid": "0510f432-bc9d-4b48-a131-cc95b95f987b", "name": "", "x": 38.61321159266958, "y": -122.45774317693665, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a6614f5e-517f-46cf-b049-09337d57228a", "name": "p1rdt6279lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0510f432-bc9d-4b48-a131-cc95b95f987b"}}}}, {"uuid": "ffeb8cee-60ff-44ce-9b89-c90087251208", "name": "", "x": 38.613584450478484, "y": -122.45866725103048, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d46fd47-37f5-48a0-ba0d-d0746e6e6da3", "name": "p1rlv13061", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ffeb8cee-60ff-44ce-9b89-c90087251208"}}}}, {"uuid": "a7225ef2-cbbe-49a3-8b48-2c2e91ae95c5", "name": "", "x": 38.6133095747888, "y": -122.45770086863982, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cb21415c-fc85-4197-82e5-545cb7be2ce9", "name": "p1rdt6270-p1rdt6279x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a7225ef2-cbbe-49a3-8b48-2c2e91ae95c5"}}}}, {"uuid": "099a9c55-b1e0-4be0-af0f-adc080f914d6", "name": "", "x": 38.612910443068216, "y": -122.45907432656523, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e1565cfb-f699-47db-9cbf-a76c32e3ea69", "name": "p1rdt6270-p1rdt6279xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "099a9c55-b1e0-4be0-af0f-adc080f914d6"}}}}, {"uuid": "0c2c958b-2765-4873-9426-4fa8b298bc4c", "name": "", "x": 38.61301688005345, "y": -122.45941707430568, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5c579309-9c05-4bae-ab97-2eca485e5ea7", "name": "p1rdt6270-p1rdt6279xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0c2c958b-2765-4873-9426-4fa8b298bc4c"}}}}, {"uuid": "be1c5948-74ad-4790-a797-5c9bd7d6e7f9", "name": "", "x": 38.61683166262397, "y": -122.45474510217191, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "07992f45-0c92-4a10-837d-4f58599d9b75", "name": "p1rdt6273lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be1c5948-74ad-4790-a797-5c9bd7d6e7f9"}}}}, {"uuid": "6be47282-79b1-4511-94e5-ba580ff9b1bf", "name": "", "x": 38.61682643350382, "y": -122.4546916792451, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "051eba03-4728-4626-8add-5410b5326dc7", "name": "p1rlv13050", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6be47282-79b1-4511-94e5-ba580ff9b1bf"}}}}, {"uuid": "b647496e-436e-4fc4-84b3-eded4e8a1dbb", "name": "", "x": 38.6162564916241, "y": -122.45492283366434, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b2f8b91d-339f-4151-90df-b0cad5c2f05a", "name": "p1rdt6268", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b647496e-436e-4fc4-84b3-eded4e8a1dbb"}}}}, {"uuid": "db758a6a-9d1d-4ea1-816d-048640f12fc9", "name": "", "x": 38.61683285323747, "y": -122.45479901485551, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4d04f281-f394-432b-8b5c-cc1acb741369", "name": "p1rdt6273", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "db758a6a-9d1d-4ea1-816d-048640f12fc9"}}}}, {"uuid": "57780dd4-af7d-49dd-9de4-ad650c6a06a4", "name": "", "x": 38.61589336043255, "y": -122.45601994462623, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b31c2adb-e4f4-4211-aac7-f317bf325d12", "name": "p1rdt6268-p1rdt6276xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "57780dd4-af7d-49dd-9de4-ad650c6a06a4"}}}}, {"uuid": "d29d0187-de06-4d15-97ce-b21f4a1f04fa", "name": "", "x": 38.61634551176407, "y": -122.45552215649514, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ce404489-b775-486b-9379-a30c801f6f94", "name": "p1rdt6268-p1rdt6276xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d29d0187-de06-4d15-97ce-b21f4a1f04fa"}}}}, {"uuid": "8012248e-cccf-438a-8364-34bcc51f62c8", "name": "", "x": 38.61623050711647, "y": -122.4548802311643, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "68d2e030-852f-44f6-9e02-d5587a1fc6a0", "name": "p1rdt6268-p1rdt6276x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8012248e-cccf-438a-8364-34bcc51f62c8"}}}}, {"uuid": "a176b6e8-4da7-46f4-9ac6-cced26eb5e19", "name": "", "x": 38.616457957404585, "y": -122.4575517341824, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "51eefb94-724e-4dfe-9823-0f6cf8f56101", "name": "p1rdt6278", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a176b6e8-4da7-46f4-9ac6-cced26eb5e19"}}}}, {"uuid": "cc466d34-d930-4734-9094-61f34464eca8", "name": "", "x": 38.61591934452827, "y": -122.45606254734442, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "315af04d-a032-43a8-a2da-b9e68fd21f39", "name": "p1rdt6276", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc466d34-d930-4734-9094-61f34464eca8"}}}}, {"uuid": "1f9d8fc5-698a-40b8-adc4-7b10d6df6183", "name": "", "x": 38.616039041002885, "y": -122.45805901946764, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1dd4f893-7921-41c3-9e9e-d33e3680a999", "name": "p1rdt6277", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1f9d8fc5-698a-40b8-adc4-7b10d6df6183"}}}}, {"uuid": "d1d13ad6-e94b-45fe-8357-d6f81f83b860", "name": "", "x": 38.61556885068546, "y": -122.45905436217652, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "699595d6-8e08-41b1-8c3a-2aef170bb5f7", "name": "p1rdt6269-p1rdt6277x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1d13ad6-e94b-45fe-8357-d6f81f83b860"}}}}, {"uuid": "36918a38-3551-4a37-9465-3fda5261e1f9", "name": "", "x": 38.58377814515449, "y": -122.50670177876174, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "70bad714-71c1-4341-ac40-76312417dd03", "name": "p1rdt6045lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "36918a38-3551-4a37-9465-3fda5261e1f9"}}}}, {"uuid": "9e1584f4-9724-4c9e-ac13-d6b255344a7e", "name": "", "x": 38.58357344171333, "y": -122.50663601797484, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cc71e486-4a44-466d-bc57-85591b269949", "name": "p1rlv12555", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9e1584f4-9724-4c9e-ac13-d6b255344a7e"}}}}, {"uuid": "451fea3b-acbb-4e8f-9fea-77a4fda7de34", "name": "", "x": 38.58366602224418, "y": -122.50744271243232, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9d830a1b-6971-4f4d-99bd-945e0785b5aa", "name": "p1rdt6052lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "451fea3b-acbb-4e8f-9fea-77a4fda7de34"}}}}, {"uuid": "659f553d-9923-4b22-86f3-a0526d8303ff", "name": "", "x": 38.583654744101715, "y": -122.507354817808, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "29476f95-f85b-4843-a847-3d9d99da3b74", "name": "p1rlv12567", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "659f553d-9923-4b22-86f3-a0526d8303ff"}}}}, {"uuid": "95152bb2-254c-4961-8510-d3ef791e29bc", "name": "", "x": 38.58176166095416, "y": -122.50864860767257, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d1c8eb9-7f79-49ad-9e93-6c7cdcc95e22", "name": "p1rdt8902lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "95152bb2-254c-4961-8510-d3ef791e29bc"}}}}, {"uuid": "81cdea77-c892-4abd-93bc-946ff7be1759", "name": "", "x": 38.58164914879979, "y": -122.50832144611942, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a02024b5-aa74-4e07-b043-a7a0e8b3e816", "name": "p1rlv19164", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "81cdea77-c892-4abd-93bc-946ff7be1759"}}}}, {"uuid": "309b639b-14c0-47a6-8c13-ad4e20b47956", "name": "", "x": 38.57552859055316, "y": -122.51515559102107, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c3f191ff-f8f2-4f13-af83-e67d1fdd366a", "name": "p1rdt6537lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "309b639b-14c0-47a6-8c13-ad4e20b47956"}}}}, {"uuid": "5cf221cf-25ef-476c-af52-9402540f80d9", "name": "", "x": 38.575486581492186, "y": -122.51516107668057, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fe1a5da7-bdac-46a6-ab32-addc4f02a296", "name": "p1rlv13720", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5cf221cf-25ef-476c-af52-9402540f80d9"}}}}, {"uuid": "b8957f06-0823-465f-8389-1f4b1f7e4316", "name": "", "x": 38.575576829321776, "y": -122.51521644999882, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "45aca6e5-a8ee-4f45-80f3-e227379d33af", "name": "p1rdt6530-p1rdt6537x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b8957f06-0823-465f-8389-1f4b1f7e4316"}}}}, {"uuid": "af35ac47-262a-4419-82ab-afddde769dc1", "name": "", "x": 38.57557088455815, "y": -122.51515412712796, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "902291fa-9561-4f40-a4b7-4fd9fdded417", "name": "p1rdt6537", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "af35ac47-262a-4419-82ab-afddde769dc1"}}}}, {"uuid": "7cdaa1b9-0c0d-4944-9718-3cdadc5f131b", "name": "", "x": 38.56672395074998, "y": -122.5002666540795, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "41e61263-feb6-4264-965a-fd1309d997a1", "name": "p1rdt7313lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7cdaa1b9-0c0d-4944-9718-3cdadc5f131b"}}}}, {"uuid": "a5a69c8d-398f-44f6-a78a-cb55e8a7fb4d", "name": "", "x": 38.566682740186856, "y": -122.50025430587122, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "13eabcb1-332a-4c7a-8042-214ada721424", "name": "p1rlv15628", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a5a69c8d-398f-44f6-a78a-cb55e8a7fb4d"}}}}, {"uuid": "6dab9a69-1039-4816-bab2-3d238cf7bc4b", "name": "", "x": 38.566766241557346, "y": -122.50026502368816, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1a3a5e1c-77a2-4a9d-89e0-7d1c94176787", "name": "p1rdt7313", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6dab9a69-1039-4816-bab2-3d238cf7bc4b"}}}}, {"uuid": "44f035bc-740e-4f8c-86ee-3b2ed3b46052", "name": "", "x": 38.563855959465826, "y": -122.50868105587648, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f0c42b48-7ca4-465f-b17c-048cb5f6d79b", "name": "p1rdt7091lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "44f035bc-740e-4f8c-86ee-3b2ed3b46052"}}}}, {"uuid": "912aee73-148f-4e1f-af3c-8095f22549b6", "name": "", "x": 38.56387029221525, "y": -122.50873180728178, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "64634ab5-a5b0-45ae-9763-7d0be029350f", "name": "p1rlv15196", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "912aee73-148f-4e1f-af3c-8095f22549b6"}}}}, {"uuid": "3e40222f-8bb5-4b72-b0a8-3c1677f45386", "name": "", "x": 38.56720551439007, "y": -122.4954680905678, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f718935b-704d-4374-9172-856511e1eddd", "name": "p1rdt5658lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e40222f-8bb5-4b72-b0a8-3c1677f45386"}}}}, {"uuid": "e55dae49-706c-4edc-b323-1c5994e7842a", "name": "", "x": 38.56720030404839, "y": -122.4954147012043, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4747e0f3-2a66-4e5a-8160-ac0aabe34489", "name": "p1rlv11679", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e55dae49-706c-4edc-b323-1c5994e7842a"}}}}, {"uuid": "a496582f-3ab4-48b4-8bbe-9d948841118a", "name": "", "x": 38.56720668600247, "y": -122.49552196704039, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "81d6db26-881f-4cae-9514-df4c1e71c76e", "name": "p1rdt5658", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a496582f-3ab4-48b4-8bbe-9d948841118a"}}}}, {"uuid": "1e229978-bde6-49d6-88ef-a59ac7598fc7", "name": "", "x": 38.65216422809464, "y": -122.48679328426424, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0bab7e6b-74a6-4fe4-95e1-4ef96084f730", "name": "p1rdt5236-p1rdt8138x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1e229978-bde6-49d6-88ef-a59ac7598fc7"}}}}, {"uuid": "8e8eb4b7-82cc-4705-8d79-553180a38da3", "name": "", "x": 38.61289959602905, "y": -122.4594654458467, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "658514b3-59fd-44b7-95d6-a34cafcb47c5", "name": "p1rdt6270-p1rdt6271x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8e8eb4b7-82cc-4705-8d79-553180a38da3"}}}}, {"uuid": "cef73316-4e05-44ba-b446-d7d3a9c4fde4", "name": "", "x": 38.58084780242867, "y": -122.5096251869554, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c9938a5c-b1cd-4592-814d-324ff2eb6644", "name": "p1rdt6500-p1rdt6519x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cef73316-4e05-44ba-b446-d7d3a9c4fde4"}}}}, {"uuid": "10ccc3bc-3003-4ac7-b98e-a169941c9b43", "name": "", "x": 38.58086518694643, "y": -122.50946246615781, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "addd9f38-279f-4d9e-b216-38faef1940c7", "name": "p1rdt6519", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10ccc3bc-3003-4ac7-b98e-a169941c9b43"}}}}, {"uuid": "95e0e7cd-6529-4d7c-a009-4b5b33ed93ec", "name": "", "x": 38.58105786983961, "y": -122.50938072179505, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "acd6da90-895c-4d2c-80b4-1712b3949993", "name": "p1rdt6515-p1rdt6535x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "95e0e7cd-6529-4d7c-a009-4b5b33ed93ec"}}}}, {"uuid": "18ac8c15-27a3-4d77-af88-1d8055d5385e", "name": "", "x": 38.581060631396625, "y": -122.50954681794376, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b13053e-033e-4fe9-8eb3-89389e4bdc2b", "name": "p1rdt6535", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "18ac8c15-27a3-4d77-af88-1d8055d5385e"}}}}, {"uuid": "a4a67019-41da-4511-8cc7-c84f86f0e2b8", "name": "", "x": 38.58103206808594, "y": -122.50926637153142, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e0103161-4b16-4d25-a1f3-5a939317461f", "name": "p1rdt6515-p1rdt6536x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a4a67019-41da-4511-8cc7-c84f86f0e2b8"}}}}, {"uuid": "ba0629ba-5833-457a-b255-6ff9469bcdcf", "name": "", "x": 38.58096111560494, "y": -122.50912674534362, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8f5cda74-5e33-4c52-8b2c-76bcd5e6c5cb", "name": "p1rdt6536", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ba0629ba-5833-457a-b255-6ff9469bcdcf"}}}}, {"uuid": "ece0a614-8728-4152-bad4-c2f58d2cff06", "name": "", "x": 38.580843572870805, "y": -122.50968387919501, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "78b3b940-c277-441f-b2b3-83525ed85fcb", "name": "p1rdt6500", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ece0a614-8728-4152-bad4-c2f58d2cff06"}}}}, {"uuid": "a6631bf9-7546-47a7-b00b-9c15f3d90c15", "name": "", "x": 38.58105789188953, "y": -122.50931876846892, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f1537ab1-dc7c-4bbd-b347-fc740d54fcf7", "name": "p1rdt6515", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a6631bf9-7546-47a7-b00b-9c15f3d90c15"}}}}, {"uuid": "af42ea4f-a084-4c6c-9c59-95018e4fa65f", "name": "", "x": 38.58107734523138, "y": -122.50929094375307, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6ef5115d-ad7b-4671-b984-b9fd5969bf61", "name": "p1rdt6528", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "af42ea4f-a084-4c6c-9c59-95018e4fa65f"}}}}, {"uuid": "a3ccc5ea-84ec-45d4-9bc1-bd1015516736", "name": "", "x": 38.581426753801445, "y": -122.50903479519879, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9d887dbc-43bd-413e-8e72-5c95a2ed0be8", "name": "p1rdt8898", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a3ccc5ea-84ec-45d4-9bc1-bd1015516736"}}}}, {"uuid": "876c20e0-46d2-4171-bdcd-67bcae4f8a23", "name": "", "x": 38.581560713176216, "y": -122.50889655325749, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d9f12ed7-454c-4cc9-a631-377121a07ba5", "name": "p1rdt6532", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "876c20e0-46d2-4171-bdcd-67bcae4f8a23"}}}}, {"uuid": "549b0bcc-dd32-407b-a3ba-c7ee12c8c856", "name": "", "x": 38.5818039862915, "y": -122.50867642493746, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4f44ec9b-338a-4ae1-a26b-26422f218c13", "name": "p1rdt8902", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "549b0bcc-dd32-407b-a3ba-c7ee12c8c856"}}}}, {"uuid": "8ac7b79d-e22a-43be-ae62-480551b5dfe1", "name": "", "x": 38.58368183290747, "y": -122.50738908690626, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c10f182d-aa76-4633-9a84-f41e20b97da1", "name": "p1rdt6052", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8ac7b79d-e22a-43be-ae62-480551b5dfe1"}}}}, {"uuid": "58116fa8-1381-4b41-93df-1ced21da2f7f", "name": "", "x": 38.58371771254211, "y": -122.50730845553447, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "67bc3ce6-e23d-4899-b0e8-9783225338ff", "name": "p1rdt6046", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "58116fa8-1381-4b41-93df-1ced21da2f7f"}}}}, {"uuid": "bb9375da-bd01-4e61-94d0-a3db80a2f7d9", "name": "", "x": 38.58374436086863, "y": -122.50721642241469, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "87e05b2f-c346-452c-9c72-a6db090c3124", "name": "p1rdt6043", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bb9375da-bd01-4e61-94d0-a3db80a2f7d9"}}}}, {"uuid": "bf36148b-0b67-4e21-ba79-bb14f0d9b9a2", "name": "", "x": 38.613253340793605, "y": -122.45775080611988, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "632d8db5-5220-4188-94f0-f6131253820b", "name": "p1rdt6279", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bf36148b-0b67-4e21-ba79-bb14f0d9b9a2"}}}}, {"uuid": "3aa676ae-ebff-47f5-8913-13e464709b7d", "name": "", "x": 38.58052230427394, "y": -122.51054930766253, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "edf27f1d-b486-434e-92be-963bdeb26090", "name": "p1rdt6501-p1rdt9468x_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3aa676ae-ebff-47f5-8913-13e464709b7d"}}}}, {"uuid": "6eae70b0-8f38-48a1-8e62-c39823216437", "name": "", "x": 38.58140313016848, "y": -122.50982713555175, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e62ba05d-920f-4f55-b1c6-3aa078e0073d", "name": "p1rdt8902-p1rdt9377x_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6eae70b0-8f38-48a1-8e62-c39823216437"}}}}, {"uuid": "9cecf942-f125-4fc9-9f2d-23b443d58d44", "name": "", "x": 38.649913359314574, "y": -122.40176189052858, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8ccc9dcb-3a72-4f11-9bcf-e3a7f1a21985", "name": "p1rdt5195_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9cecf942-f125-4fc9-9f2d-23b443d58d44"}}}}, {"uuid": "54c5be93-4f2a-45c3-9b63-c3f7a44b0522", "name": "", "x": 38.68940056320115, "y": -122.44266975467744, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6b3c997d-cd47-439c-aeb9-326e12c2b869", "name": "p1rdt28lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "54c5be93-4f2a-45c3-9b63-c3f7a44b0522"}}}}, {"uuid": "14523271-bd86-41a7-aced-3e5e00efc0df", "name": "", "x": 38.68955085092013, "y": -122.44265311463495, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8ccef6af-4bf6-44dc-b292-2bf9503a374a", "name": "p1rlv51", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "14523271-bd86-41a7-aced-3e5e00efc0df"}}}}, {"uuid": "d1625529-9e08-4fbd-818b-487e4402e667", "name": "", "x": 38.689199515506125, "y": -122.44267883689947, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b3c62646-6132-41ef-ba14-a06789885cd5", "name": "p1rlv53", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1625529-9e08-4fbd-818b-487e4402e667"}}}}, {"uuid": "ab3986aa-349f-43ce-8609-e96791097421", "name": "", "x": 38.68719967792895, "y": -122.44202477655993, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "61fc3980-6aa4-415c-91c1-10d32c7c359c", "name": "p1rdt29lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ab3986aa-349f-43ce-8609-e96791097421"}}}}, {"uuid": "1232b5c1-d445-40db-859a-e61961a053ad", "name": "", "x": 38.68717368875977, "y": -122.44198213704887, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fec0a162-4b0c-4577-b878-8dbc7c9935fc", "name": "p1rlv52", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1232b5c1-d445-40db-859a-e61961a053ad"}}}}, {"uuid": "c345d1a1-14da-4a8c-a8bb-3e2c621c0204", "name": "", "x": 38.70237353390803, "y": -122.38204661340717, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4d2be3b5-dbfc-4099-af9a-96368e60fe23", "name": "p1rdt30lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c345d1a1-14da-4a8c-a8bb-3e2c621c0204"}}}}, {"uuid": "bc6d9158-f2b3-4cb0-9930-c6984365a7fc", "name": "", "x": 38.702248770449096, "y": -122.38177565760685, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "346dad85-3bf8-41a6-97ea-6b3b40a7f22e", "name": "p1rlv62", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bc6d9158-f2b3-4cb0-9930-c6984365a7fc"}}}}, {"uuid": "a7109162-f295-4719-8eaf-7cdf8aee7649", "name": "", "x": 38.70225996977785, "y": -122.382189570322, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c89ec162-cda3-4c40-8833-3fff085538ba", "name": "p1rdm56", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a7109162-f295-4719-8eaf-7cdf8aee7649"}}}}, {"uuid": "e4ce90f8-02a1-46dd-96c2-c7b8972e5363", "name": "", "x": 38.70215104431212, "y": -122.38204100448107, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "20010301-32ce-4cc0-ab59-04ef3bcd35d7", "name": "p1rlv54", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e4ce90f8-02a1-46dd-96c2-c7b8972e5363"}}}}, {"uuid": "e1200df2-4a75-4e15-8956-eaeb9ff30ccf", "name": "", "x": 38.70125472363682, "y": -122.37955319837823, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "59ff3c1b-38f4-4a33-86fa-e956951c0f2c", "name": "p1rdm58", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e1200df2-4a75-4e15-8956-eaeb9ff30ccf"}}}}, {"uuid": "a1fd30d9-7410-4c78-ba22-7372d3d81998", "name": "", "x": 38.701204180575694, "y": -122.37968411246109, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "36bdbc4e-edfa-425a-8e4c-e6123b567555", "name": "p1rlv55", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a1fd30d9-7410-4c78-ba22-7372d3d81998"}}}}, {"uuid": "4662f7a8-368e-4162-b872-3bc8f29531a6", "name": "", "x": 38.70120618742273, "y": -122.37889811298928, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f678ceb4-b717-44a5-9db9-f698bece6935", "name": "p1rdm60", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4662f7a8-368e-4162-b872-3bc8f29531a6"}}}}, {"uuid": "1b5b11ca-9f19-43b7-b13f-e7164ddc0619", "name": "", "x": 38.701314750425446, "y": -122.37897767463447, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25b891ce-797a-4a4d-b664-4225fba806c4", "name": "p1rlv152", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1b5b11ca-9f19-43b7-b13f-e7164ddc0619"}}}}, {"uuid": "833f8c3b-2661-4791-8f47-042ec9e5cd7a", "name": "", "x": 38.70133109954647, "y": -122.37964493055146, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3510eedd-535c-4e58-b81e-c5ec09030479", "name": "p1rdt31lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "833f8c3b-2661-4791-8f47-042ec9e5cd7a"}}}}, {"uuid": "3acc2e31-a59c-40ed-95ee-1341730b1e49", "name": "", "x": 38.7016002020804, "y": -122.3801252205059, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3a0a4841-bf31-4498-98d9-115cc159981c", "name": "p1rdm59", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3acc2e31-a59c-40ed-95ee-1341730b1e49"}}}}, {"uuid": "d52a647b-da63-4a12-93c7-3e1012a0e903", "name": "", "x": 38.701475019236376, "y": -122.38031030323685, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a32ee184-f677-4333-b7ee-7bc30ab41467", "name": "p1rlv58", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d52a647b-da63-4a12-93c7-3e1012a0e903"}}}}, {"uuid": "a84c9fe6-6be3-4d57-b05a-1e617ace728e", "name": "", "x": 38.70278615488254, "y": -122.38061347297433, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e374d6d6-1e75-4808-b65a-c7033e1bd528", "name": "p1rdt32lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a84c9fe6-6be3-4d57-b05a-1e617ace728e"}}}}, {"uuid": "675a026f-8f3a-4d6a-b336-f2a97a0172d3", "name": "", "x": 38.70279286082068, "y": -122.38071294165577, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ec2c1edd-78b1-4436-85cc-2fbc7d880b87", "name": "p1rlv414", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "675a026f-8f3a-4d6a-b336-f2a97a0172d3"}}}}, {"uuid": "3435bd69-9f3b-43ca-98a0-ec2de3c18d97", "name": "", "x": 38.70248568513053, "y": -122.3805660873002, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cef7aa37-7ca0-4130-9bcd-1804a811245a", "name": "p1rdm61", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3435bd69-9f3b-43ca-98a0-ec2de3c18d97"}}}}, {"uuid": "4e71fca8-0890-4db7-be87-fe294459781e", "name": "", "x": 38.702478683531616, "y": -122.38094565722146, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4694811a-ba43-4c78-b957-5209b1d961e2", "name": "p1rlv56", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4e71fca8-0890-4db7-be87-fe294459781e"}}}}, {"uuid": "4854c4d7-5bd8-4724-af9a-4acd5b27e364", "name": "", "x": 38.70162164245257, "y": -122.38472111973375, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "065c8583-45e5-466c-b4c0-1c66bf970abe", "name": "p1rdt33lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4854c4d7-5bd8-4724-af9a-4acd5b27e364"}}}}, {"uuid": "4199baea-30b5-43b2-b88c-0c1faf4aee21", "name": "", "x": 38.701985008267755, "y": -122.38473348273297, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0f7dbd18-1cbe-49d3-b490-3c46cf8e37f1", "name": "p1rlv170", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4199baea-30b5-43b2-b88c-0c1faf4aee21"}}}}, {"uuid": "78bbc070-dc8e-4410-8d4e-4f606565bf7c", "name": "", "x": 38.70159540402429, "y": -122.38433431596432, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b0538c66-18d7-440e-9efd-6b2945d50f2b", "name": "p1rdm63", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "78bbc070-dc8e-4410-8d4e-4f606565bf7c"}}}}, {"uuid": "fa50dadb-5ee3-46b3-a4eb-9ab06e3f7516", "name": "", "x": 38.70131629597425, "y": -122.38438270952352, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "925cb3b7-4ced-4a36-913f-e6851ed79b98", "name": "p1rlv57", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa50dadb-5ee3-46b3-a4eb-9ab06e3f7516"}}}}, {"uuid": "1d46a1cc-204e-4ea8-8397-e723f39f0b45", "name": "", "x": 38.70167064130821, "y": -122.38493167921865, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cfa2eaff-b163-46ce-b6e5-516680d39bc3", "name": "p1rdm64", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d46a1cc-204e-4ea8-8397-e723f39f0b45"}}}}, {"uuid": "7e6bb48b-c23f-44a8-978e-196d3e00c442", "name": "", "x": 38.70145424916845, "y": -122.38491053257476, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d22bf2f5-74cc-47c7-ae3b-410fba27c113", "name": "p1rlv61", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7e6bb48b-c23f-44a8-978e-196d3e00c442"}}}}, {"uuid": "0bcbb846-2e59-45fb-83c2-51c537155626", "name": "", "x": 38.7023106935151, "y": -122.37870903978225, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "72ee0111-4849-4280-b3c9-c0627d1a6c09", "name": "p1rdm66", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0bcbb846-2e59-45fb-83c2-51c537155626"}}}}, {"uuid": "4825661b-6b25-4827-b894-da341ab1f2d2", "name": "", "x": 38.7024768400754, "y": -122.37889862189955, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b80bdb24-4bbf-4a57-bd5f-6a5ec9d484dd", "name": "p1rlv59", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4825661b-6b25-4827-b894-da341ab1f2d2"}}}}, {"uuid": "363693fc-8724-4e30-9695-ca77f5fdac20", "name": "", "x": 38.70222160936453, "y": -122.37888535297411, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "553a6868-acec-4492-a52d-5aa08414c612", "name": "p1rdt34lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "363693fc-8724-4e30-9695-ca77f5fdac20"}}}}, {"uuid": "236fb449-47ee-42e4-993c-3997b0af760e", "name": "", "x": 38.70217983407473, "y": -122.37897019250839, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "713c1538-ceb4-46df-a996-6c591c0f8e40", "name": "p1rdm67", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "236fb449-47ee-42e4-993c-3997b0af760e"}}}}, {"uuid": "8587aa60-c8a0-494d-8deb-56c4d60053f5", "name": "", "x": 38.70224401225384, "y": -122.37917664191762, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "64a67ed2-a563-4378-b6ac-d9a95339e862", "name": "p1rlv67", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8587aa60-c8a0-494d-8deb-56c4d60053f5"}}}}, {"uuid": "a4d2bd60-6cec-4e24-9421-7fcc9429131d", "name": "", "x": 38.701765866802305, "y": -122.38301785787249, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f98cc066-fca3-4489-9770-047caee3e742", "name": "p1rdt35lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a4d2bd60-6cec-4e24-9421-7fcc9429131d"}}}}, {"uuid": "afa28b82-3110-4dbb-add6-0fa5d3d6fb16", "name": "", "x": 38.701398104123946, "y": -122.38280649214893, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7eb0d1e8-f85e-493e-b69b-26437fdb8ad9", "name": "p1rlv60", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "afa28b82-3110-4dbb-add6-0fa5d3d6fb16"}}}}, {"uuid": "8a2dda54-7737-47d5-82f8-ae2431bf65a0", "name": "", "x": 38.7018668128423, "y": -122.38282546368364, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "23861598-ab3c-4648-9de9-3ee4316f2cb4", "name": "p1rdm69", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8a2dda54-7737-47d5-82f8-ae2431bf65a0"}}}}, {"uuid": "9e951376-bb88-44f2-a35f-e171716fdd96", "name": "", "x": 38.701495649868505, "y": -122.3825066502607, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3e00fd9b-92b3-49c4-bcc2-957b9d2c7bad", "name": "p1rlv65", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9e951376-bb88-44f2-a35f-e171716fdd96"}}}}, {"uuid": "84576a85-50a9-45c2-ab04-9bd1cad70427", "name": "", "x": 38.701815325965796, "y": -122.38044139197483, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6a4fb658-c3ba-428a-82bf-b38ae68dd908", "name": "p1rdt36lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "84576a85-50a9-45c2-ab04-9bd1cad70427"}}}}, {"uuid": "38e99712-7679-4054-95fa-2634f8c37d8a", "name": "", "x": 38.701925218075054, "y": -122.38023741663469, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8300f90c-9a3b-400d-af04-072125dce84f", "name": "p1rlv63", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "38e99712-7679-4054-95fa-2634f8c37d8a"}}}}, {"uuid": "5f6775b3-6eb9-4eae-a0a4-44ca49b16b7e", "name": "", "x": 38.70179061086173, "y": -122.38718468697783, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "074f23bd-2fb2-4480-ae4b-f1c1f754613e", "name": "p1rdm71", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5f6775b3-6eb9-4eae-a0a4-44ca49b16b7e"}}}}, {"uuid": "9a15968a-34bf-40cb-9cbf-7467e5fd4b46", "name": "", "x": 38.70156139001374, "y": -122.38697566423983, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5efd07ee-012a-40a4-97bb-07c1a5ed898c", "name": "p1rlv64", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9a15968a-34bf-40cb-9cbf-7467e5fd4b46"}}}}, {"uuid": "96e3b526-172d-4c2c-aefc-89b5cea154dc", "name": "", "x": 38.7020086293725, "y": -122.38751633252258, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "590e467f-47a6-4c7e-ae3a-83cec8dd87e3", "name": "p1rdm72", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "96e3b526-172d-4c2c-aefc-89b5cea154dc"}}}}, {"uuid": "0997e9e0-7e96-449d-bbc7-a790b2928a00", "name": "", "x": 38.7022335504919, "y": -122.38744541239329, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3fcd1ee-e6e0-4ca3-aacf-cc527b07482a", "name": "p1rlv162", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0997e9e0-7e96-449d-bbc7-a790b2928a00"}}}}, {"uuid": "437cad19-f247-4f11-a9b0-8298d9bda0d4", "name": "", "x": 38.701696448473875, "y": -122.3875919728995, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "90a16370-67f7-4abd-992c-990d1eb8f17e", "name": "p1rdt37lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "437cad19-f247-4f11-a9b0-8298d9bda0d4"}}}}, {"uuid": "e106eb24-7a01-47e1-a694-69754915affd", "name": "", "x": 38.7014985369188, "y": -122.38819919157115, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35807695-5d6d-4544-a748-a96c56b705d1", "name": "p1rdm73", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e106eb24-7a01-47e1-a694-69754915affd"}}}}, {"uuid": "626c124b-2053-457c-ab89-54c6053f1645", "name": "", "x": 38.701670353304884, "y": -122.38831272923629, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6278f6ee-7332-4de8-9d2c-83bb637f489f", "name": "p1rlv457", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "626c124b-2053-457c-ab89-54c6053f1645"}}}}, {"uuid": "5493f5af-7894-49fc-9333-23343effb6c7", "name": "", "x": 38.70178443656836, "y": -122.37918061552492, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "352f8404-f923-468a-92a5-1be2f82ffb97", "name": "p1rdm74", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5493f5af-7894-49fc-9333-23343effb6c7"}}}}, {"uuid": "421b72f0-1f89-4f6c-a02b-5fd568cf930e", "name": "", "x": 38.701833201230905, "y": -122.37934517294276, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e90eb8a2-5db0-4861-96ef-a6991a0386eb", "name": "p1rlv66", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "421b72f0-1f89-4f6c-a02b-5fd568cf930e"}}}}, {"uuid": "33e19b23-b8c7-42b8-babb-ef9a8fd5ed1a", "name": "", "x": 38.701967149573, "y": -122.37911401099093, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "752aca33-7682-4e8c-a8b1-624467e02958", "name": "p1rdt38lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "33e19b23-b8c7-42b8-babb-ef9a8fd5ed1a"}}}}, {"uuid": "4c76e541-3e5a-43d7-aaa5-8196b790733b", "name": "", "x": 38.70235732979096, "y": -122.37866677526797, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2332f175-22ca-4894-b63d-246f5c11c572", "name": "p1rdm75", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c76e541-3e5a-43d7-aaa5-8196b790733b"}}}}, {"uuid": "f32f7bc5-6f90-4089-bec7-957167f1b819", "name": "", "x": 38.70211516673608, "y": -122.37867174586772, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c22aa2c8-a6fc-4b27-a875-e07e3f50ecac", "name": "p1rlv68", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f32f7bc5-6f90-4089-bec7-957167f1b819"}}}}, {"uuid": "da3b2612-960a-4760-b9db-3d1126101c02", "name": "", "x": 38.70178670019972, "y": -122.38549505637238, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "131099af-6f69-4531-bebf-e457ff5d7624", "name": "p1rdm76", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "da3b2612-960a-4760-b9db-3d1126101c02"}}}}, {"uuid": "c4fc819d-a932-4943-a7a8-b0008212d9bb", "name": "", "x": 38.701430782199786, "y": -122.38558924083848, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "876ffb0b-f33c-45b2-a085-7b34103ecffc", "name": "p1rlv69", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c4fc819d-a932-4943-a7a8-b0008212d9bb"}}}}, {"uuid": "0c79e619-8b46-4eb9-bbc3-ee2b7d368108", "name": "", "x": 38.701700119673376, "y": -122.38533518862636, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "623ec6b4-cb70-4437-9d79-5ec577bc3199", "name": "p1rdt39lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0c79e619-8b46-4eb9-bbc3-ee2b7d368108"}}}}, {"uuid": "8d15705c-b29e-458e-bd87-cc5cf3dbeb93", "name": "", "x": 38.70169870333672, "y": -122.38512694165256, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a909c826-1682-47f0-926c-0a67c9ff2a3a", "name": "p1rdm77", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8d15705c-b29e-458e-bd87-cc5cf3dbeb93"}}}}, {"uuid": "64ec693c-962c-4b4a-9a29-91692e5a3162", "name": "", "x": 38.701429210818716, "y": -122.38529025109813, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e53e7714-06d1-4f85-89c5-f152629e8ab7", "name": "p1rlv70", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "64ec693c-962c-4b4a-9a29-91692e5a3162"}}}}, {"uuid": "2e095ced-7dff-4118-9fbf-14b823e34b71", "name": "", "x": 38.6940139373904, "y": -122.37587462456409, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0d08444c-79a3-4ba0-8c69-1855a600dea0", "name": "p1rdt40lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2e095ced-7dff-4118-9fbf-14b823e34b71"}}}}, {"uuid": "0528c2c9-59dc-445a-bef7-3c20da20571c", "name": "", "x": 38.694063719222605, "y": -122.37569816102457, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "46cd88d0-b2c4-492a-af3d-d9ae886d0089", "name": "p1rlv143", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0528c2c9-59dc-445a-bef7-3c20da20571c"}}}}, {"uuid": "8b6a46f9-678f-4bdb-a630-5ce3f058dd3c", "name": "", "x": 38.69389087842103, "y": -122.37592566558304, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "435b1814-b0a6-40e3-a446-efe5b7fce133", "name": "p1rdm78", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8b6a46f9-678f-4bdb-a630-5ce3f058dd3c"}}}}, {"uuid": "a236f6f0-a10f-4bf6-a548-7064bf59a629", "name": "", "x": 38.69394647992354, "y": -122.3762126554526, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d7791de-0cf6-4901-8b95-2d67870f09f5", "name": "p1rlv71", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a236f6f0-a10f-4bf6-a548-7064bf59a629"}}}}, {"uuid": "f171115a-d335-42de-bb3e-cf5763cbcfa4", "name": "", "x": 38.69007704448215, "y": -122.37273530129958, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "793d0bf4-4d9f-4df4-bc95-d528dd7d31d5", "name": "p1rdt41lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f171115a-d335-42de-bb3e-cf5763cbcfa4"}}}}, {"uuid": "856fb6a1-3188-4dd5-8c7a-893d5944fa36", "name": "", "x": 38.68993682745413, "y": -122.37294747048301, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fc710fc3-ae5f-478e-997b-85467db7c93c", "name": "p1rlv72", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "856fb6a1-3188-4dd5-8c7a-893d5944fa36"}}}}, {"uuid": "a8e4f13a-5f5a-476e-b077-18b4f9da8bd1", "name": "", "x": 38.69017871415686, "y": -122.37268089773576, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "188047cd-3f14-4240-91fe-30113d48152b", "name": "p1rlv88", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8e4f13a-5f5a-476e-b077-18b4f9da8bd1"}}}}, {"uuid": "f760aebd-d2f9-4cdb-b451-2aba7e341a70", "name": "", "x": 38.69058527350743, "y": -122.3740266335316, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8fb27dc9-b404-49d1-84dd-0cde418b037d", "name": "p1rdt42lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f760aebd-d2f9-4cdb-b451-2aba7e341a70"}}}}, {"uuid": "cc1fe186-7eff-40cc-9087-6a08b3f0ffe7", "name": "", "x": 38.69045558452261, "y": -122.37389730590256, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "540e0121-fc39-4c2c-9fbc-012c020f5994", "name": "p1rlv86", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc1fe186-7eff-40cc-9087-6a08b3f0ffe7"}}}}, {"uuid": "d3dae137-37c2-4439-a8f7-287d04577a69", "name": "", "x": 38.690475022656685, "y": -122.3741615988237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c5f4300c-037f-42b5-a390-31ec1e8396b3", "name": "p1rdm82", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d3dae137-37c2-4439-a8f7-287d04577a69"}}}}, {"uuid": "ef7eaa33-52e1-434c-ab86-e12bd472fcf6", "name": "", "x": 38.69028492385651, "y": -122.37400227840031, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f4e2991c-1404-44da-bbb5-5a2ebc43bde4", "name": "p1rlv73", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef7eaa33-52e1-434c-ab86-e12bd472fcf6"}}}}, {"uuid": "9138a962-fd56-4f0f-8b21-acd66f15530f", "name": "", "x": 38.69038564798742, "y": -122.37430035768564, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5696ebea-257d-4cc1-9ae4-61c98563b706", "name": "p1rdm86", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9138a962-fd56-4f0f-8b21-acd66f15530f"}}}}, {"uuid": "dbb08176-39c0-4dbc-bf74-460d00d2f441", "name": "", "x": 38.690005204334135, "y": -122.37393572632347, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "afc70b80-ab76-440c-b05b-149458051675", "name": "p1rlv108", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dbb08176-39c0-4dbc-bf74-460d00d2f441"}}}}, {"uuid": "493507a6-2031-493a-ad6b-ef369cb0a201", "name": "", "x": 38.690672040311505, "y": -122.37392991440464, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "49a07eb5-9c9b-479c-a345-b09f72725a21", "name": "p1rdm83", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "493507a6-2031-493a-ad6b-ef369cb0a201"}}}}, {"uuid": "2233f4a7-d806-4388-900b-9d41df1e287d", "name": "", "x": 38.69071765074636, "y": -122.37403300248825, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0ef51371-3fa2-400a-a2b4-3afa97ff2419", "name": "p1rlv75", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2233f4a7-d806-4388-900b-9d41df1e287d"}}}}, {"uuid": "021c8fa6-1ab5-4a3b-b913-398dd6563305", "name": "", "x": 38.69090781102859, "y": -122.374203821834, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c5c96953-6710-4765-b5bd-4359e03e4c63", "name": "p1rlv130", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "021c8fa6-1ab5-4a3b-b913-398dd6563305"}}}}, {"uuid": "04e8ac20-3f95-4330-ad5d-f2b52e4280e4", "name": "", "x": 38.690788633118785, "y": -122.37382541248327, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ae45c08d-f629-4ff9-9c23-838b6e34da88", "name": "p1rdm84", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "04e8ac20-3f95-4330-ad5d-f2b52e4280e4"}}}}, {"uuid": "a8c38f40-05f1-4874-8046-4003ead1c4b8", "name": "", "x": 38.69085275864737, "y": -122.37402032667815, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e4dd2283-6100-48ce-b4bc-0e37b7b4e409", "name": "p1rlv79", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8c38f40-05f1-4874-8046-4003ead1c4b8"}}}}, {"uuid": "6c2fe5a3-78de-415f-9829-d2fa73ee39cb", "name": "", "x": 38.6908423930519, "y": -122.37376745173289, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d93360fa-3106-4444-9488-e73c6997ab71", "name": "p1rdm87", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c2fe5a3-78de-415f-9829-d2fa73ee39cb"}}}}, {"uuid": "59650fe8-d7a3-4405-94bf-13ea9d2f0b8e", "name": "", "x": 38.69085830065978, "y": -122.37390131828276, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "919a48e8-b378-4dd5-8e33-a2602fb58bc0", "name": "p1rlv115", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59650fe8-d7a3-4405-94bf-13ea9d2f0b8e"}}}}, {"uuid": "ca498dfc-d663-4237-a8fa-b38fa64f72e5", "name": "", "x": 38.6907528455112, "y": -122.37219295067007, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b812c54c-1689-47cf-beba-55faea943380", "name": "p1rdm90", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ca498dfc-d663-4237-a8fa-b38fa64f72e5"}}}}, {"uuid": "3eae7d71-071a-434a-936e-6fdec158239c", "name": "", "x": 38.69077167044301, "y": -122.37234226546438, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8e6de569-7f61-439e-a402-850c4f071ab3", "name": "p1rlv117", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3eae7d71-071a-434a-936e-6fdec158239c"}}}}, {"uuid": "0268316d-2bf7-483d-9aa8-55b9a7921399", "name": "", "x": 38.69123428534169, "y": -122.37237669444208, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "274aa0ec-f229-454c-b52d-23130bacb97e", "name": "p1rdt43lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0268316d-2bf7-483d-9aa8-55b9a7921399"}}}}, {"uuid": "3c4120d9-5325-4f01-8812-99a68d778116", "name": "", "x": 38.69134864004529, "y": -122.37238321787136, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0c82df28-72fa-4cf0-a844-8a6bf90e548b", "name": "p1rdm91", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3c4120d9-5325-4f01-8812-99a68d778116"}}}}, {"uuid": "4b05856f-25b9-4d86-8769-f887c528efb3", "name": "", "x": 38.691310990079565, "y": -122.37208458594603, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "54ca5205-5b71-42f2-8e24-c24f768a7a5c", "name": "p1rlv137", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4b05856f-25b9-4d86-8769-f887c528efb3"}}}}, {"uuid": "e736d97a-899f-460c-8076-87e1284f06d6", "name": "", "x": 38.69147492155732, "y": -122.37240511152062, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "acbf36c3-9c53-417f-98c1-fa1b5d4b60f4", "name": "p1rdm89", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e736d97a-899f-460c-8076-87e1284f06d6"}}}}, {"uuid": "36cb466e-9a0d-404d-bb08-cbf2ab13e1cf", "name": "", "x": 38.69153009984452, "y": -122.37261160297146, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5861410e-9d6d-423e-b967-2f2af65610b8", "name": "p1rlv74", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "36cb466e-9a0d-404d-bb08-cbf2ab13e1cf"}}}}, {"uuid": "66056a0b-621e-4e55-bd59-a4d2a449b4ab", "name": "", "x": 38.68938630771864, "y": -122.37020536032335, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c813f8a2-226b-431d-a41a-195cf5e8b01a", "name": "p1rdt44lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "66056a0b-621e-4e55-bd59-a4d2a449b4ab"}}}}, {"uuid": "4d54cf4d-36c1-4945-87e0-3fd1a67d9930", "name": "", "x": 38.68939678035235, "y": -122.37025840439561, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3354497f-6de7-405d-9fca-a9c77463dc27", "name": "p1rlv76", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d54cf4d-36c1-4945-87e0-3fd1a67d9930"}}}}, {"uuid": "e60fd94a-3e00-42ec-9121-2277b286d677", "name": "", "x": 38.690057823403926, "y": -122.37534955818452, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a5151d03-c8b3-41f2-a2cd-743aa8ea0fea", "name": "p1rdm93", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e60fd94a-3e00-42ec-9121-2277b286d677"}}}}, {"uuid": "6aa6e8f9-2731-4404-98c5-2d662c4bad90", "name": "", "x": 38.690220088213884, "y": -122.37535964547071, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f88a22a3-7e6c-4fc5-a8f4-a08cdaa3f5d6", "name": "p1rlv77", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6aa6e8f9-2731-4404-98c5-2d662c4bad90"}}}}, {"uuid": "eb9baf82-ce99-4bd0-b3d6-0bd99fd767c6", "name": "", "x": 38.68996899986402, "y": -122.37559179451463, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4dece5f0-ab6c-40ed-9ec6-0b1377d19e78", "name": "p1rdm94", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eb9baf82-ce99-4bd0-b3d6-0bd99fd767c6"}}}}, {"uuid": "e0a75be7-9eaf-4cdf-895a-1fe48b985539", "name": "", "x": 38.69013175574531, "y": -122.37569386454011, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ee33d90b-2f70-4c9d-863d-6486b95280b8", "name": "p1rlv119", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e0a75be7-9eaf-4cdf-895a-1fe48b985539"}}}}, {"uuid": "f33811d4-8e5e-4b75-98e4-e9e3ee105acd", "name": "", "x": 38.69009885909427, "y": -122.37512675776652, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e276abc-bb27-47e4-9de8-adaccbf964dd", "name": "p1rdt45lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f33811d4-8e5e-4b75-98e4-e9e3ee105acd"}}}}, {"uuid": "68d8f819-82c6-4f68-9d22-add5ca1a825e", "name": "", "x": 38.690225535592255, "y": -122.37469269533909, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a363b9b6-b80f-42cf-942e-17e723376ae6", "name": "p1rdm95", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "68d8f819-82c6-4f68-9d22-add5ca1a825e"}}}}, {"uuid": "1a0ff510-44f5-4e40-bac9-94d0f3d35467", "name": "", "x": 38.690035314507966, "y": -122.37451037852996, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "41960437-e2e6-4746-89c2-81c81602ca1b", "name": "p1rlv132", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1a0ff510-44f5-4e40-bac9-94d0f3d35467"}}}}, {"uuid": "c13588a5-fd65-4f01-ae00-29a3387c1182", "name": "", "x": 38.69396497728804, "y": -122.37461414459213, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2e93e7ed-6686-4fb2-8410-867f2cdbdab2", "name": "p1rdm96", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c13588a5-fd65-4f01-ae00-29a3387c1182"}}}}, {"uuid": "6c7ef76f-bde8-48eb-ad13-be3a39952c52", "name": "", "x": 38.69396985964566, "y": -122.37499754256292, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ae76f058-b79a-4c0f-90be-f9cd7a02bcfc", "name": "p1rlv78", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c7ef76f-bde8-48eb-ad13-be3a39952c52"}}}}, {"uuid": "05ef71ac-c109-4339-afed-73fc1b83ea7f", "name": "", "x": 38.694118107766265, "y": -122.3746013122857, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fdd576f2-a7e2-46eb-b2b0-818c4a97e694", "name": "p1rdm97", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "05ef71ac-c109-4339-afed-73fc1b83ea7f"}}}}, {"uuid": "c48aa8da-1798-4362-b5b7-73a858fb724c", "name": "", "x": 38.69415593578412, "y": -122.37493445252295, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "46ee0e6c-daf7-4412-94a7-5332a6a97656", "name": "p1rlv87", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c48aa8da-1798-4362-b5b7-73a858fb724c"}}}}, {"uuid": "b54fc4bd-352b-4d49-b123-d8ec37be6db1", "name": "", "x": 38.69382389629988, "y": -122.3746653446421, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aacdcb46-43e3-4147-ac25-3a9c1223e13a", "name": "p1rdt46lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b54fc4bd-352b-4d49-b123-d8ec37be6db1"}}}}, {"uuid": "e2d6efe2-38ba-4c3b-b704-9868be4eaae7", "name": "", "x": 38.69332609771847, "y": -122.37479218972346, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "70024d6c-94dd-4367-aeec-92d4bc5eec04", "name": "p1rdm98", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e2d6efe2-38ba-4c3b-b704-9868be4eaae7"}}}}, {"uuid": "948b06e4-a51d-4cd8-9bbb-9811f9996cee", "name": "", "x": 38.69336355649941, "y": -122.37505633665255, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ea9e5f8c-8477-403c-9d3a-911c4e5ab5c8", "name": "p1rlv138", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "948b06e4-a51d-4cd8-9bbb-9811f9996cee"}}}}, {"uuid": "f5d7283b-3a19-4218-880f-573c260dbb07", "name": "", "x": 38.69221243814819, "y": -122.3732880387573, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f031530a-b3fc-4f8e-b0ac-139009d1256c", "name": "p1rdt47lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5d7283b-3a19-4218-880f-573c260dbb07"}}}}, {"uuid": "9763b498-7e70-4ea0-9f4b-4bcd8a123c33", "name": "", "x": 38.692092560795636, "y": -122.3733081060302, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ab7e1b4a-f8ec-4211-b7a0-d7f9057f576a", "name": "p1rlv80", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9763b498-7e70-4ea0-9f4b-4bcd8a123c33"}}}}, {"uuid": "3ebad1dc-7b5d-4af3-8e2f-3e90cf714ce3", "name": "", "x": 38.69236265310078, "y": -122.37325975482375, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "db8f484a-94d5-4d20-8ebf-6708b1601a0d", "name": "p1rlv92", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3ebad1dc-7b5d-4af3-8e2f-3e90cf714ce3"}}}}, {"uuid": "29dc9d0c-aa67-46c7-9211-3b7d980cf123", "name": "", "x": 38.69245991415173, "y": -122.3717601018108, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2f1790fe-a399-46e3-b9e3-5979837777ce", "name": "p1rdt48lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "29dc9d0c-aa67-46c7-9211-3b7d980cf123"}}}}, {"uuid": "74ea0e90-f021-45c2-985c-a3cb88385ae9", "name": "", "x": 38.69259843146321, "y": -122.37185485582063, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ef92e40c-fe3c-4f7f-b844-884e1079e491", "name": "p1rlv81", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "74ea0e90-f021-45c2-985c-a3cb88385ae9"}}}}, {"uuid": "ed97c978-5fd5-4907-ba53-bcb6fa43fb14", "name": "", "x": 38.69231864911266, "y": -122.37177681198607, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a02925cd-7c5b-475f-9e91-30d639bb3c33", "name": "p1rlv120", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ed97c978-5fd5-4907-ba53-bcb6fa43fb14"}}}}, {"uuid": "7335310a-682c-4c5b-b04f-96fb5d0bacdd", "name": "", "x": 38.6924795549249, "y": -122.37153393231236, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fd7286c0-4c57-435f-bed2-fd9a927de8cc", "name": "p1rdm103", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7335310a-682c-4c5b-b04f-96fb5d0bacdd"}}}}, {"uuid": "240896b9-48a3-485b-afb2-209b3f5be2ac", "name": "", "x": 38.69255749370678, "y": -122.3714717809419, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4b02739e-d082-4c54-8deb-8ccc83ab82ab", "name": "p1rlv122", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "240896b9-48a3-485b-afb2-209b3f5be2ac"}}}}, {"uuid": "ed627fe4-0241-47e2-8e66-d0911edf3483", "name": "", "x": 38.693056440809926, "y": -122.37376716989863, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1e5bcc7e-f35c-4bbf-a7ff-a82817488b11", "name": "p1rdt49lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ed627fe4-0241-47e2-8e66-d0911edf3483"}}}}, {"uuid": "9c7705ad-1ce1-4efa-8baa-ac126fb5596d", "name": "", "x": 38.69309336879344, "y": -122.37340286288783, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "da2538bd-189b-4699-823b-ed459d94b422", "name": "p1rlv146", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9c7705ad-1ce1-4efa-8baa-ac126fb5596d"}}}}, {"uuid": "ff84e052-dc91-47d5-bf3f-d8465156a1f6", "name": "", "x": 38.693365493783084, "y": -122.37373395481842, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2409ced2-7817-40af-951f-33d725e9d75a", "name": "p1rdm104", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ff84e052-dc91-47d5-bf3f-d8465156a1f6"}}}}, {"uuid": "7fab99d1-39c7-4a67-a26a-a490bd18a53e", "name": "", "x": 38.69333125539768, "y": -122.3735427494079, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c3ddd704-2530-4392-8e9e-06e047b12f41", "name": "p1rlv82", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7fab99d1-39c7-4a67-a26a-a490bd18a53e"}}}}, {"uuid": "34c1c8cf-98d9-40f7-b221-800f7416fd25", "name": "", "x": 38.69285166538173, "y": -122.3737039387965, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a8385921-c183-4c26-bc99-bf5f0364c18b", "name": "p1rdm105", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "34c1c8cf-98d9-40f7-b221-800f7416fd25"}}}}, {"uuid": "559f04ef-a41b-4fc7-a97a-f8206ab479b3", "name": "", "x": 38.69285080314527, "y": -122.3735429639113, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "096e92a6-ea34-435e-a059-57d5234e1654", "name": "p1rlv107", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "559f04ef-a41b-4fc7-a97a-f8206ab479b3"}}}}, {"uuid": "af091acb-e936-456d-99d0-a49daa8431ea", "name": "", "x": 38.69316443073551, "y": -122.37605094152133, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8208c617-caa9-46a5-b28a-8a5b0d9898a2", "name": "p1rdt50lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "af091acb-e936-456d-99d0-a49daa8431ea"}}}}, {"uuid": "e529b33c-2b5c-4d79-84c2-a61b3b4aecc8", "name": "", "x": 38.69310634340839, "y": -122.3758289932297, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6ae7b1fe-08c4-4848-867e-e2426a325a99", "name": "p1rlv127", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e529b33c-2b5c-4d79-84c2-a61b3b4aecc8"}}}}, {"uuid": "f47c80f2-4d96-4104-a074-926b1622c44f", "name": "", "x": 38.69329674648888, "y": -122.37604581609166, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7948c980-abf7-4357-9ff8-4be9122a3167", "name": "p1rdm107", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f47c80f2-4d96-4104-a074-926b1622c44f"}}}}, {"uuid": "65d557de-e7d9-4492-96b2-9b1bf64cbb04", "name": "", "x": 38.69321156388965, "y": -122.37581260405913, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "24c3e8d8-1520-4a05-84af-a70da6140b4d", "name": "p1rlv83", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65d557de-e7d9-4492-96b2-9b1bf64cbb04"}}}}, {"uuid": "ff8cd1ac-4285-4784-8478-d357b8b3d1ce", "name": "", "x": 38.69331611852453, "y": -122.37629862181807, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6184fe8d-ae60-426a-8c0c-a3cc56c5b67e", "name": "p1rlv123", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ff8cd1ac-4285-4784-8478-d357b8b3d1ce"}}}}, {"uuid": "a9bb9f0a-c1ee-4814-8831-4afd88339097", "name": "", "x": 38.692999373711416, "y": -122.37604839940005, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c2deeb6a-3ea7-44d9-9ee0-b013733dadc4", "name": "p1rdm110", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a9bb9f0a-c1ee-4814-8831-4afd88339097"}}}}, {"uuid": "c03cc8c8-a4ae-4a69-bea0-b62060e3309c", "name": "", "x": 38.692941715957275, "y": -122.37590693919702, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cbdefe7a-517b-495b-88b8-dcf15a9429ff", "name": "p1rlv135", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c03cc8c8-a4ae-4a69-bea0-b62060e3309c"}}}}, {"uuid": "be69abca-c06f-493d-baf9-5ac7009a85d4", "name": "", "x": 38.692481049048034, "y": -122.37128492416231, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "09d7f030-a9b4-4705-82af-6cf140ba64d1", "name": "p1rdt51lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be69abca-c06f-493d-baf9-5ac7009a85d4"}}}}, {"uuid": "462dc74b-1c9a-44f1-a2d7-8681441fa9d6", "name": "", "x": 38.69252947996807, "y": -122.37076308321973, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "55e7538f-4bde-4810-a237-ac0cad7ba805", "name": "p1rlv84", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "462dc74b-1c9a-44f1-a2d7-8681441fa9d6"}}}}, {"uuid": "de0ee001-0810-4d03-9b34-91f9ab41b7cb", "name": "", "x": 38.6922695134408, "y": -122.37101833090937, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0060c029-188f-4725-a935-8d0d9cc892f7", "name": "p1rlv93", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "de0ee001-0810-4d03-9b34-91f9ab41b7cb"}}}}, {"uuid": "a39ff69c-ac92-4842-90cc-f3461b549300", "name": "", "x": 38.69210249623662, "y": -122.37348049869223, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a5dd2d9f-42d5-48c4-b1e1-34ae6aa555df", "name": "p1rdm113", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a39ff69c-ac92-4842-90cc-f3461b549300"}}}}, {"uuid": "90a4515d-a43d-4958-b510-8804455e348b", "name": "", "x": 38.69211341663018, "y": -122.37383686081611, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dcc52dd9-bacb-4e49-a057-d3747f89a7f7", "name": "p1rlv85", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "90a4515d-a43d-4958-b510-8804455e348b"}}}}, {"uuid": "3871a0c1-a5e7-4f51-9ba1-836ee2375900", "name": "", "x": 38.69236400854256, "y": -122.37351271362792, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f42789f3-35c3-4d0d-adda-2044adce92c0", "name": "p1rdm114", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3871a0c1-a5e7-4f51-9ba1-836ee2375900"}}}}, {"uuid": "96de4a8f-3d07-40c8-9322-a027d76c4048", "name": "", "x": 38.69234050594775, "y": -122.37364337983433, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6a1f01bc-d1f1-4d92-b1e2-1f8223624c52", "name": "p1rlv91", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "96de4a8f-3d07-40c8-9322-a027d76c4048"}}}}, {"uuid": "5f73ddf1-4313-4186-92b7-7545d7cb1de3", "name": "", "x": 38.691649262567026, "y": -122.37351497173694, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c70a7331-8c41-4370-b053-3eae432d52ae", "name": "p1rdt52lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5f73ddf1-4313-4186-92b7-7545d7cb1de3"}}}}, {"uuid": "8bbf286f-4457-45c4-a843-ea91d2a17f4d", "name": "", "x": 38.691390973585875, "y": -122.37355569590474, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d2d46cd2-9caf-47a7-b134-a29fccd91b9c", "name": "p1rdm115", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8bbf286f-4457-45c4-a843-ea91d2a17f4d"}}}}, {"uuid": "3cc3de65-5492-4f37-9a52-c57850ceb521", "name": "", "x": 38.691389371784915, "y": -122.37325674863969, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "db2d4080-1f43-47a3-9f3a-e25d1e4f5076", "name": "p1rlv94", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3cc3de65-5492-4f37-9a52-c57850ceb521"}}}}, {"uuid": "dc46f775-942e-4b57-a70e-ebee5a398f00", "name": "", "x": 38.69141053564886, "y": -122.3738429881131, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "85afc796-3fe5-4027-b84e-10d502124636", "name": "p1rlv103", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dc46f775-942e-4b57-a70e-ebee5a398f00"}}}}, {"uuid": "9f9870ad-18ce-4f8e-aafd-27e9a5ce0884", "name": "", "x": 38.691455037994594, "y": -122.373739113497, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4b7dbf54-f6bc-4e20-b2f3-8c63a44dd993", "name": "p1rlv144", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9f9870ad-18ce-4f8e-aafd-27e9a5ce0884"}}}}, {"uuid": "d1dd480a-e298-46fc-bde3-865df51decce", "name": "", "x": 38.69127394993667, "y": -122.37357971347488, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a0d6e82b-cba7-4c7e-8715-d73c3530bad7", "name": "p1rdm116", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1dd480a-e298-46fc-bde3-865df51decce"}}}}, {"uuid": "fd74d192-e637-48d7-8d35-d8fbaeb298f5", "name": "", "x": 38.691299813396455, "y": -122.37336101652306, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "82f19d5c-0941-411d-8baa-3ba029471dae", "name": "p1rlv98", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fd74d192-e637-48d7-8d35-d8fbaeb298f5"}}}}, {"uuid": "b6cdcfae-cff8-4e49-ad15-f9b8de0e80f3", "name": "", "x": 38.69128456220349, "y": -122.37387858172916, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b45d086e-8e0d-42f4-a8ec-6d3a9579a96b", "name": "p1rlv136", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b6cdcfae-cff8-4e49-ad15-f9b8de0e80f3"}}}}, {"uuid": "8ddc7d7f-da7a-419c-9197-b4d0540b8ba5", "name": "", "x": 38.69265743519212, "y": -122.37614335951521, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "329f78a6-af13-4ceb-bc87-4660d497c22e", "name": "p1rdm122", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8ddc7d7f-da7a-419c-9197-b4d0540b8ba5"}}}}, {"uuid": "10bc977a-803e-4f0f-ba15-de1ba41eb822", "name": "", "x": 38.69254776576972, "y": -122.37585684466497, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d3367cc2-b096-4cfb-ae71-038eb9e06b46", "name": "p1rlv125", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10bc977a-803e-4f0f-ba15-de1ba41eb822"}}}}, {"uuid": "ce535576-0e9b-4e7c-b655-cde66068e7df", "name": "", "x": 38.692649343871935, "y": -122.37631591047503, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aa8af0a4-4d55-41e4-83d1-4fe349920e38", "name": "p1rlv148", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ce535576-0e9b-4e7c-b655-cde66068e7df"}}}}, {"uuid": "911b88f2-844c-45e2-ae9a-b20256b0016c", "name": "", "x": 38.69275631408947, "y": -122.37609650577265, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8d595142-3854-4152-b64a-6cda8396a523", "name": "p1rdm121", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "911b88f2-844c-45e2-ae9a-b20256b0016c"}}}}, {"uuid": "c13e3655-f460-4dd1-aecb-af05f8e64a35", "name": "", "x": 38.69270022130948, "y": -122.3757175352468, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "66748ae6-b6ef-4228-bb0f-f9a121f0e1a3", "name": "p1rlv111", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c13e3655-f460-4dd1-aecb-af05f8e64a35"}}}}, {"uuid": "341b2db8-4359-479b-94c7-4683b22cf69d", "name": "", "x": 38.692882349552875, "y": -122.37607241348934, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e2e27276-ea6c-40a3-92d3-4648ec9d235d", "name": "p1rdm123", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "341b2db8-4359-479b-94c7-4683b22cf69d"}}}}, {"uuid": "6513d061-1878-4780-8a4f-3b4468228566", "name": "", "x": 38.692817981929934, "y": -122.37583149911002, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "499fb461-ccb6-436a-8078-eec9beffb4a9", "name": "p1rlv131", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6513d061-1878-4780-8a4f-3b4468228566"}}}}, {"uuid": "5305b25b-d732-4948-8e2a-120bdd4e9ee1", "name": "", "x": 38.69257937121657, "y": -122.37618250960169, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2536a0eb-a35c-40d4-9773-b78379e7481a", "name": "p1rdt53lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5305b25b-d732-4948-8e2a-120bdd4e9ee1"}}}}, {"uuid": "71836ddb-b0aa-495c-a6dd-453ad997e814", "name": "", "x": 38.69241474350349, "y": -122.3762604541736, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e9f62740-f47f-4c97-bae7-4380fe83fcbc", "name": "p1rdm124", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "71836ddb-b0aa-495c-a6dd-453ad997e814"}}}}, {"uuid": "0078fa0b-43fb-419f-bd42-e6fd99824e8f", "name": "", "x": 38.69237796229021, "y": -122.37612278955407, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eb69a6a9-3eaf-4fc3-82be-0eec77455a82", "name": "p1rlv141", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0078fa0b-43fb-419f-bd42-e6fd99824e8f"}}}}, {"uuid": "d7bb4578-cd1e-44b4-a117-fcfb149a76f4", "name": "", "x": 38.69212730175752, "y": -122.37643542970159, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d1071344-55a0-4684-9fbf-5729ec1f21c2", "name": "p1rdm120", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d7bb4578-cd1e-44b4-a117-fcfb149a76f4"}}}}, {"uuid": "f1b03aac-33b7-4dd4-9479-ae369e39696d", "name": "", "x": 38.692072620801916, "y": -122.37632091820853, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "24d75e9a-0249-48ca-ad10-32738bb6a519", "name": "p1rlv89", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f1b03aac-33b7-4dd4-9479-ae369e39696d"}}}}, {"uuid": "a53dd899-1fb1-46fd-b738-e94aa524e450", "name": "", "x": 38.690545533550726, "y": -122.37333707739843, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "57889d14-4aac-4aee-a9e2-677a047e8054", "name": "p1rdt54lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a53dd899-1fb1-46fd-b738-e94aa524e450"}}}}, {"uuid": "d58e8629-1002-48f1-8063-585740bce5a9", "name": "", "x": 38.690111985440346, "y": -122.3736818329642, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e06b2ac7-926e-4caf-afac-386910d4ea5e", "name": "p1rlv90", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d58e8629-1002-48f1-8063-585740bce5a9"}}}}, {"uuid": "e419a944-3cee-407a-af22-419361162c4c", "name": "", "x": 38.69031825985071, "y": -122.37349606102795, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4fe82ede-430d-454d-b9d0-e212d0621ea1", "name": "p1rlv105", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e419a944-3cee-407a-af22-419361162c4c"}}}}, {"uuid": "6f475d0a-f83e-4632-b565-29f42721ed71", "name": "", "x": 38.69409341663082, "y": -122.37388461682215, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "85ad3bf0-7e82-4e32-8106-faddcf725bdf", "name": "p1rdt56lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6f475d0a-f83e-4632-b565-29f42721ed71"}}}}, {"uuid": "20af2ea4-a9f6-4e7d-9cf0-b224359b9df0", "name": "", "x": 38.693962208985816, "y": -122.37409671723277, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "31508077-f731-47cb-94a9-869d7910e406", "name": "p1rlv96", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "20af2ea4-a9f6-4e7d-9cf0-b224359b9df0"}}}}, {"uuid": "a9937757-1991-4707-aad9-564a014df7a1", "name": "", "x": 38.694453827235925, "y": -122.37334499797639, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a60b127d-0530-495e-b3b9-2ebabf070fa1", "name": "p1rdm131", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a9937757-1991-4707-aad9-564a014df7a1"}}}}, {"uuid": "508ecc8e-1f06-4f5a-8b96-19bce68709b4", "name": "", "x": 38.69441870621642, "y": -122.37351778932282, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a11ba246-99d9-4cf5-a557-bec53c75e6fb", "name": "p1rlv804", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "508ecc8e-1f06-4f5a-8b96-19bce68709b4"}}}}, {"uuid": "c05965fd-98d6-49ab-b7ed-438036a0cab8", "name": "", "x": 38.69031197102896, "y": -122.37232328557447, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4bf5bf18-363d-4f4e-bf10-9ffc601c0f30", "name": "p1rdm133", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c05965fd-98d6-49ab-b7ed-438036a0cab8"}}}}, {"uuid": "16c92af6-c70a-4596-b4d0-70df593ccca4", "name": "", "x": 38.69039362804738, "y": -122.37242605719072, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bc4a448a-c6cb-4714-b8e6-b75bc6bc219c", "name": "p1rlv99", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "16c92af6-c70a-4596-b4d0-70df593ccca4"}}}}, {"uuid": "4c1aabbe-0b3e-4cb5-8d6c-f778f2aea5ba", "name": "", "x": 38.69048579257096, "y": -122.37227974908389, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e3367c40-9f47-42d9-b627-bc502b170f2a", "name": "p1rdt58lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c1aabbe-0b3e-4cb5-8d6c-f778f2aea5ba"}}}}, {"uuid": "d328a29f-ee37-4a80-a029-55b6cb1e5ea2", "name": "", "x": 38.69060891171015, "y": -122.37224020218359, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32e76273-c930-4506-9610-8cbfca04af67", "name": "p1rdm134", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d328a29f-ee37-4a80-a029-55b6cb1e5ea2"}}}}, {"uuid": "8a619225-2829-4897-911e-5c71a4d46e70", "name": "", "x": 38.69066464553883, "y": -122.37255017170527, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48d1be49-5aca-4e18-8b85-2a1274b3f26d", "name": "p1rlv101", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8a619225-2829-4897-911e-5c71a4d46e70"}}}}, {"uuid": "4e0e8d3c-7c65-411b-9610-d85c9d4654d5", "name": "", "x": 38.69344092722396, "y": -122.37604456356478, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a7b11b31-78f1-41fa-b511-df76daad0efc", "name": "p1rdm135", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4e0e8d3c-7c65-411b-9610-d85c9d4654d5"}}}}, {"uuid": "e138768b-008a-4552-b69b-4aa8538cf63a", "name": "", "x": 38.69344227667356, "y": -122.37629752630082, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "62a0d673-eaba-4032-9038-8095e2d53999", "name": "p1rlv100", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e138768b-008a-4552-b69b-4aa8538cf63a"}}}}, {"uuid": "fe421763-978a-4d59-8ddf-5f15b7e8f858", "name": "", "x": 38.69361499553134, "y": -122.37604702739569, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8aca9934-9439-4ce6-9ee3-475980324054", "name": "p1rdt59lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fe421763-978a-4d59-8ddf-5f15b7e8f858"}}}}, {"uuid": "1a258a18-33ff-49b6-af22-3f303a0cb210", "name": "", "x": 38.69374688178432, "y": -122.37596141343235, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a415176a-ddab-47a0-9ce7-54c53c4c0f11", "name": "p1rdm136", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1a258a18-33ff-49b6-af22-3f303a0cb210"}}}}, {"uuid": "20b67a46-6909-495f-95d4-ec7eeead6efe", "name": "", "x": 38.69371837494324, "y": -122.37568568791933, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0dbaab50-3abc-4207-82dc-5fcc5be68aad", "name": "p1rlv121", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "20b67a46-6909-495f-95d4-ec7eeead6efe"}}}}, {"uuid": "6ee52466-2ac9-43a0-afb5-55b532be96bf", "name": "", "x": 38.69088191916026, "y": -122.37220729684483, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d2517cea-05d3-4b7f-b9fc-0df0fde81235", "name": "p1rdt60lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6ee52466-2ac9-43a0-afb5-55b532be96bf"}}}}, {"uuid": "ebddd272-2642-4382-93c8-732a7e251cf7", "name": "", "x": 38.690940600905, "y": -122.3719153472003, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "06a432e3-dd37-4c52-b954-6652bb529c8e", "name": "p1rlv102", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ebddd272-2642-4382-93c8-732a7e251cf7"}}}}, {"uuid": "d34b3076-2883-4efd-a327-df823cfc09ce", "name": "", "x": 38.6914549432012, "y": -122.37540639973672, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e53344e0-e328-4acd-b159-e1f8cc246996", "name": "p1rdm138", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d34b3076-2883-4efd-a327-df823cfc09ce"}}}}, {"uuid": "65aeaed9-9c37-4058-be93-e0d605ed9fe2", "name": "", "x": 38.69137249020519, "y": -122.3751541495459, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c76c5b8f-1994-470c-a024-b97c73b9bb41", "name": "p1rlv104", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65aeaed9-9c37-4058-be93-e0d605ed9fe2"}}}}, {"uuid": "03b11a14-27fc-4ea8-843f-062716cd853d", "name": "", "x": 38.69120075557791, "y": -122.37558860981264, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "70f11a44-826f-45b8-9dc3-0f51ce6c9733", "name": "p1rdt61lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "03b11a14-27fc-4ea8-843f-062716cd853d"}}}}, {"uuid": "3143231f-7aee-4214-acd2-38fc402f9656", "name": "", "x": 38.69118822551713, "y": -122.37608712916376, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "022bda10-6b1a-408b-a231-adb63e189d14", "name": "p1rdm139", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3143231f-7aee-4214-acd2-38fc402f9656"}}}}, {"uuid": "13ab2b32-9d28-4487-81f1-93b0f2bdb41c", "name": "", "x": 38.691080519301316, "y": -122.37616855391688, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e5ca78b-6151-4a35-8a04-1bab215f0f10", "name": "p1rlv124", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "13ab2b32-9d28-4487-81f1-93b0f2bdb41c"}}}}, {"uuid": "8313fe5a-77d6-4a80-a7cd-5eef33ed7059", "name": "", "x": 38.693600768265796, "y": -122.37276202285804, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fac6d4e1-b14d-4973-9626-6a4bde2d2a42", "name": "p1rdt63lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8313fe5a-77d6-4a80-a7cd-5eef33ed7059"}}}}, {"uuid": "d428aee0-32db-49a7-b1b4-0ec78e144463", "name": "", "x": 38.69345061514859, "y": -122.37280180665408, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c76fc99c-c160-4ed0-85dd-ec3da962bb24", "name": "p1rlv109", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d428aee0-32db-49a7-b1b4-0ec78e144463"}}}}, {"uuid": "08ec40fb-604c-4457-9274-469a0579239f", "name": "", "x": 38.6932526134289, "y": -122.3728495309013, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25edc94b-a44b-4200-8cde-73941c2818b8", "name": "p1rlv112", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "08ec40fb-604c-4457-9274-469a0579239f"}}}}, {"uuid": "ed2e38b0-cdbf-45f9-9605-3518d40c2b3c", "name": "", "x": 38.69373045846697, "y": -122.37289135400576, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "21b14d95-6634-4f0e-a380-d5e57328d825", "name": "p1rdm143", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ed2e38b0-cdbf-45f9-9605-3518d40c2b3c"}}}}, {"uuid": "73fade0f-c897-4b49-8bd1-e189d59eef12", "name": "", "x": 38.69364972680421, "y": -122.37296105211496, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8b515111-3455-471a-aba8-92c82624a195", "name": "p1rlv139", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "73fade0f-c897-4b49-8bd1-e189d59eef12"}}}}, {"uuid": "b345efc1-ee77-4dc0-8990-db5453affdff", "name": "", "x": 38.6938583426107, "y": -122.37321220673307, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "09182ca9-8ea2-4d1c-9c3e-5850a77c1b66", "name": "p1rdm145", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b345efc1-ee77-4dc0-8990-db5453affdff"}}}}, {"uuid": "d8c833e7-f9ae-40b3-954e-fc43f94fe057", "name": "", "x": 38.69399264902756, "y": -122.37305004970418, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2756378a-0c67-47cf-969d-bdb9e55c8a4b", "name": "p1rlv113", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d8c833e7-f9ae-40b3-954e-fc43f94fe057"}}}}, {"uuid": "1fe742ec-1cfe-4dc9-bc90-282a353ece23", "name": "", "x": 38.69377761075648, "y": -122.37328190461031, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "56bc8935-c658-424c-83d8-0d13bf8d292a", "name": "p1rlv128", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1fe742ec-1cfe-4dc9-bc90-282a353ece23"}}}}, {"uuid": "4fc8e4df-cce5-4fd7-a029-1788d5853eb5", "name": "", "x": 38.694126443783816, "y": -122.37332088048717, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2ae9cb89-7cb8-48c6-a5bc-4178ee364ae8", "name": "p1rdt65lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4fc8e4df-cce5-4fd7-a029-1788d5853eb5"}}}}, {"uuid": "026d3939-bb21-4f6c-855c-b54a7898f18e", "name": "", "x": 38.694562147559466, "y": -122.3733785499152, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "de7551d6-5168-440c-8fe2-9f17e0904c29", "name": "p1rdm147", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "026d3939-bb21-4f6c-855c-b54a7898f18e"}}}}, {"uuid": "e11d221e-d445-4bf9-b913-3b02f6e74ea6", "name": "", "x": 38.69465084301279, "y": -122.37311329835559, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e7ffe87d-4424-4495-83c1-6765d385207c", "name": "p1rlv838", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e11d221e-d445-4bf9-b913-3b02f6e74ea6"}}}}, {"uuid": "9dfdfc2c-853e-4c2b-9385-252d60851f2d", "name": "", "x": 38.767616650522, "y": -122.38054158855523, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dfb9fa3b-c758-4c2e-bc51-f297b1ed21bf", "name": "p1rdt66lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9dfdfc2c-853e-4c2b-9385-252d60851f2d"}}}}, {"uuid": "2538c3eb-b1bc-4ee5-8b00-fa5f18ac8f48", "name": "", "x": 38.767590639077596, "y": -122.38049892417555, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d7934cd3-dcd6-4b67-8206-8a3636b6f75d", "name": "p1rlv114", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2538c3eb-b1bc-4ee5-8b00-fa5f18ac8f48"}}}}, {"uuid": "342627f1-23fc-4fc1-801a-3d315338bc32", "name": "", "x": 38.76719268838157, "y": -122.36058092984808, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bd2d6296-a302-4027-9e5f-c24a56a1a1ac", "name": "p1rdt68lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "342627f1-23fc-4fc1-801a-3d315338bc32"}}}}, {"uuid": "d877fb1b-68a6-4726-933b-8b5b97ff3748", "name": "", "x": 38.76717558814645, "y": -122.36126774194496, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "247e37b3-d6d0-41d7-a6b3-ee29d415da50", "name": "p1rlv118", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d877fb1b-68a6-4726-933b-8b5b97ff3748"}}}}, {"uuid": "da398a4c-6151-40cc-aced-2f61d4aa4fc6", "name": "", "x": 38.689974435374744, "y": -122.37228069359776, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7057debb-bd4d-4156-a253-0f3a14cdd784", "name": "p1rdt69lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "da398a4c-6151-40cc-aced-2f61d4aa4fc6"}}}}, {"uuid": "28269207-9ffd-447f-813e-276f53697dd2", "name": "", "x": 38.68985295036364, "y": -122.37243078084407, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c6c42586-4f46-45c6-910f-90fca771cfd2", "name": "p1rlv129", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "28269207-9ffd-447f-813e-276f53697dd2"}}}}, {"uuid": "750d9357-0219-4629-9238-6ea19caae837", "name": "", "x": 38.68983375524, "y": -122.37221248161097, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "47b7d9f8-ca72-4a77-af67-74ee561f7f10", "name": "p1rlv140", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "750d9357-0219-4629-9238-6ea19caae837"}}}}, {"uuid": "ef755cd7-5294-40c4-91c0-5cf1aacdfadb", "name": "", "x": 38.69318495516089, "y": -122.37483189069003, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "02440066-bc62-4629-96c5-4b497827de5b", "name": "p1rdt70lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef755cd7-5294-40c4-91c0-5cf1aacdfadb"}}}}, {"uuid": "35da9aa8-9637-4cb6-bec3-23001af4bfad", "name": "", "x": 38.69327375078167, "y": -122.3751146121051, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "31dc8280-eb14-4f87-85d7-8eae17013fe7", "name": "p1rlv133", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "35da9aa8-9637-4cb6-bec3-23001af4bfad"}}}}, {"uuid": "e492d455-8b95-4140-896e-122720e148d6", "name": "", "x": 38.69171296593506, "y": -122.37647352235795, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "43d5d2c5-10f6-4e89-91fa-5186f269b659", "name": "p1rdm155", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e492d455-8b95-4140-896e-122720e148d6"}}}}, {"uuid": "e65435ef-abb3-4ac1-89e5-c476f3b500f1", "name": "", "x": 38.69171223017465, "y": -122.37633554599886, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "425bdcfa-9753-4ef5-bb38-9e014ae779dc", "name": "p1rlv134", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e65435ef-abb3-4ac1-89e5-c476f3b500f1"}}}}, {"uuid": "23e3a742-b04c-4e8f-b57d-1ab749ef5509", "name": "", "x": 38.69147969326603, "y": -122.37638705727157, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e71f106d-4b41-405f-bce9-3d06b336a554", "name": "p1rdt71lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "23e3a742-b04c-4e8f-b57d-1ab749ef5509"}}}}, {"uuid": "7f986097-b809-478f-8770-78aac41b94ff", "name": "", "x": 38.69139677338097, "y": -122.37632678646379, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8357e543-eba0-4863-9d95-e34d84a3fae7", "name": "p1rdm156", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7f986097-b809-478f-8770-78aac41b94ff"}}}}, {"uuid": "7ee686cc-84ec-4ff3-9f8f-854f628ac999", "name": "", "x": 38.691395853444895, "y": -122.37615431677973, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1704e67-dfa3-4a6b-a3f4-7ebba9d27537", "name": "p1rlv145", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7ee686cc-84ec-4ff3-9f8f-854f628ac999"}}}}, {"uuid": "0431b8bc-cdf5-4f6e-b49c-eb912990b029", "name": "", "x": 38.69181140426288, "y": -122.37350205897214, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4b59eeab-d997-4186-ab59-0424644d5aeb", "name": "p1rdt72lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0431b8bc-cdf5-4f6e-b49c-eb912990b029"}}}}, {"uuid": "41d95e2a-ac27-4824-827e-3f927ed8ecc1", "name": "", "x": 38.6918879083499, "y": -122.37326787315344, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "070d9a60-c6f2-424c-bd0f-66c52d349f0c", "name": "p1rlv147", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "41d95e2a-ac27-4824-827e-3f927ed8ecc1"}}}}, {"uuid": "bcf6bf7b-ed30-4d11-94d5-a4e84b67a7c4", "name": "", "x": 38.70177173843472, "y": -122.38529743886787, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35f3fd4d-f962-4e4e-89d8-8b41a07ff57d", "name": "p1rdm158", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bcf6bf7b-ed30-4d11-94d5-a4e84b67a7c4"}}}}, {"uuid": "e036b17c-2c45-421a-a0ad-22e901b75472", "name": "", "x": 38.70192489270885, "y": -122.38529750774045, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "063e89ea-6dd0-404f-abfb-21686f3041ed", "name": "p1rlv149", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e036b17c-2c45-421a-a0ad-22e901b75472"}}}}, {"uuid": "dc1f28a1-6b0e-494c-9128-161bf7611a05", "name": "", "x": 38.701762667089824, "y": -122.38553586657494, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4f027d15-df82-4989-93e5-a3b40c862b08", "name": "p1rdt73lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dc1f28a1-6b0e-494c-9128-161bf7611a05"}}}}, {"uuid": "45cb53cc-d42e-45c1-8dea-12d137daf666", "name": "", "x": 38.7017739969935, "y": -122.38573580631073, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7b8d2667-d52b-46b3-ace4-2ad2b4e3050e", "name": "p1rdm159", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "45cb53cc-d42e-45c1-8dea-12d137daf666"}}}}, {"uuid": "ce5d58a5-24be-4e25-851b-2d3cc071d845", "name": "", "x": 38.70192743071094, "y": -122.38578049451348, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5187e006-621e-4c15-9604-0272ae62887c", "name": "p1rlv167", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ce5d58a5-24be-4e25-851b-2d3cc071d845"}}}}, {"uuid": "183e0605-103e-45e9-9163-63593da28942", "name": "", "x": 38.70203671550442, "y": -122.37747640223225, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bb4a799f-0e03-4ba6-b8ce-8f5e117fd2c2", "name": "p1rdm160", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "183e0605-103e-45e9-9163-63593da28942"}}}}, {"uuid": "b8296ec7-3cda-410c-8834-0221de56b03e", "name": "", "x": 38.70208317973028, "y": -122.37774050453031, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0b9979ec-4e43-4feb-a617-28191e9dd9d8", "name": "p1rlv150", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b8296ec7-3cda-410c-8834-0221de56b03e"}}}}, {"uuid": "9c87a630-51fc-447a-8893-3882b474b13b", "name": "", "x": 38.702169092358545, "y": -122.37748277827959, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "37880102-8a9c-4f7b-930a-b29a94241866", "name": "p1rdt74lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9c87a630-51fc-447a-8893-3882b474b13b"}}}}, {"uuid": "4e339b8e-d334-4e6e-b8b0-f354cfa78884", "name": "", "x": 38.70233414912363, "y": -122.37748532373683, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "243cdb10-5012-48b5-809f-1952913bf655", "name": "p1rdm161", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4e339b8e-d334-4e6e-b8b0-f354cfa78884"}}}}, {"uuid": "f5b304ee-ff90-4eae-9d5e-de243e25ae8c", "name": "", "x": 38.702308461860476, "y": -122.3777385521559, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0e326756-7ead-4099-a065-9f2de5693197", "name": "p1rlv169", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5b304ee-ff90-4eae-9d5e-de243e25ae8c"}}}}, {"uuid": "edb1309f-17be-473e-9536-b73605ba9cc7", "name": "", "x": 38.70182389972923, "y": -122.38611886200323, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "699bbf24-59ba-4dba-8bd4-1cf04a7e6e47", "name": "p1rdt75lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "edb1309f-17be-473e-9536-b73605ba9cc7"}}}}, {"uuid": "89e8b4bd-54f6-445d-98bc-cbfabb734b35", "name": "", "x": 38.70198343088721, "y": -122.38614802224237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "345b5c48-cd35-418e-bc08-50c06f5dff09", "name": "p1rlv151", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "89e8b4bd-54f6-445d-98bc-cbfabb734b35"}}}}, {"uuid": "fe33c8c8-9a84-4be4-9d3a-b3f0264e9519", "name": "", "x": 38.701353959316926, "y": -122.37840985382832, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4ecf2223-f120-45b4-8aab-a36d60161aec", "name": "p1rdt76lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fe33c8c8-9a84-4be4-9d3a-b3f0264e9519"}}}}, {"uuid": "8c23f4f5-3dcd-403e-892a-0178fb27e88f", "name": "", "x": 38.70149204336824, "y": -122.37842413503941, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5ccdfbc7-d3a6-4f74-ad32-25ff11a2e3b7", "name": "p1rlv154", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8c23f4f5-3dcd-403e-892a-0178fb27e88f"}}}}, {"uuid": "aeb979fd-4489-43fd-97d9-b0b766b3b211", "name": "", "x": 38.70130360088785, "y": -122.37857526759122, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0bd295ef-2c38-4c6b-915a-73900e920b92", "name": "p1rdm163", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aeb979fd-4489-43fd-97d9-b0b766b3b211"}}}}, {"uuid": "71b04380-49f0-49d3-b901-8a86282d5917", "name": "", "x": 38.70119454861773, "y": -122.37840371014978, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ebbe09dd-7560-4eff-9e32-803f14b4ce7c", "name": "p1rlv153", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "71b04380-49f0-49d3-b901-8a86282d5917"}}}}, {"uuid": "ca1e267b-7f14-4898-83f6-e667edcf4f24", "name": "", "x": 38.702363895820405, "y": -122.37852761379413, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3fd9bf7-ecdd-4dcb-966a-f426d5f2ee81", "name": "p1rdt77lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ca1e267b-7f14-4898-83f6-e667edcf4f24"}}}}, {"uuid": "b239dd78-4f54-4445-a01c-6bb955e0e274", "name": "", "x": 38.70251884097236, "y": -122.37832324388756, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2452d5af-5aba-4d4b-8cd9-27a95fe6b34d", "name": "p1rlv155", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b239dd78-4f54-4445-a01c-6bb955e0e274"}}}}, {"uuid": "447d14e7-4cba-4661-a6d7-a03c610b24ec", "name": "", "x": 38.70156690402656, "y": -122.3772504726202, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e110db24-1653-41b5-8496-821dfff05769", "name": "p1rdm166", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "447d14e7-4cba-4661-a6d7-a03c610b24ec"}}}}, {"uuid": "b80bc469-eb08-4031-91e6-8f576656fd95", "name": "", "x": 38.70172886217702, "y": -122.37720306729005, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7f607e6b-9540-4845-9f0c-6c334eb0e807", "name": "p1rlv156", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b80bc469-eb08-4031-91e6-8f576656fd95"}}}}, {"uuid": "07ca0dfe-b006-46d0-b7d7-c4e4d17b93f4", "name": "", "x": 38.7015268414049, "y": -122.37702834108411, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6f0255b7-5369-40eb-8814-959b0d4245b6", "name": "p1rdt78lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "07ca0dfe-b006-46d0-b7d7-c4e4d17b93f4"}}}}, {"uuid": "aa172697-4d3c-4c21-ad14-791eaaaae1de", "name": "", "x": 38.701501251821085, "y": -122.3767680365563, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c108a0c2-3093-4222-9547-5ac08f6d8a4a", "name": "p1rdm167", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aa172697-4d3c-4c21-ad14-791eaaaae1de"}}}}, {"uuid": "aa54beeb-e05e-40ae-b161-8212e8387d82", "name": "", "x": 38.701672466226256, "y": -122.3767665504658, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a0ae6c02-c29e-4bf9-b1d4-ecc7e37e7de2", "name": "p1rlv159", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aa54beeb-e05e-40ae-b161-8212e8387d82"}}}}, {"uuid": "fbaafc47-9f3c-4277-aaf2-71b0af1b7b7f", "name": "", "x": 38.701573552558834, "y": -122.37796740020737, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "624d03d5-ac53-4d58-ac86-62834fa13c61", "name": "p1rdt79lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fbaafc47-9f3c-4277-aaf2-71b0af1b7b7f"}}}}, {"uuid": "5d4081fd-db54-430c-9651-49ca8ccb19c8", "name": "", "x": 38.70167012893807, "y": -122.378020087898, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "61460072-bdc5-4a70-96fa-8ecfa71623f4", "name": "p1rlv164", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5d4081fd-db54-430c-9651-49ca8ccb19c8"}}}}, {"uuid": "5ddc2017-08f1-4c34-af08-946e29dacc50", "name": "", "x": 38.70151736520935, "y": -122.37810191210743, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "937989ee-4525-4394-b04f-37d77a2c910c", "name": "p1rdm168", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ddc2017-08f1-4c34-af08-946e29dacc50"}}}}, {"uuid": "6e2f44f8-35c0-4ebe-be9e-289c5eb1dec3", "name": "", "x": 38.701243377810904, "y": -122.37795080752997, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4355a473-4643-4f72-afe8-80ce773ca8e8", "name": "p1rlv157", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6e2f44f8-35c0-4ebe-be9e-289c5eb1dec3"}}}}, {"uuid": "f766d922-c367-4ee9-9fb6-96a42381bf45", "name": "", "x": 38.70217305711017, "y": -122.38794268559874, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3ce05c72-facf-447f-ba14-cc2ef64579a8", "name": "p1rdt80lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f766d922-c367-4ee9-9fb6-96a42381bf45"}}}}, {"uuid": "6a03f728-1d34-40e8-9d44-4347597d087c", "name": "", "x": 38.70228005247363, "y": -122.38772102191264, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b1cd7284-17fb-4382-a29d-dd8c5bfd7541", "name": "p1rlv158", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a03f728-1d34-40e8-9d44-4347597d087c"}}}}, {"uuid": "35d2c24a-971e-45b2-a2e3-22eccd876c81", "name": "", "x": 38.7016172629152, "y": -122.37771401826583, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1b610625-09e3-4b72-a8fe-b0c36f5e137c", "name": "p1rdt81lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "35d2c24a-971e-45b2-a2e3-22eccd876c81"}}}}, {"uuid": "f378ac7d-d200-4e41-a406-ab7054564695", "name": "", "x": 38.701704338541916, "y": -122.37767478667475, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fd2fae5a-e5dd-4ad4-8acc-422de00ae83e", "name": "p1rlv160", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f378ac7d-d200-4e41-a406-ab7054564695"}}}}, {"uuid": "85bcfea0-d3da-47ac-b484-16d7e9deb5ef", "name": "", "x": 38.7014372533443, "y": -122.37659609024615, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e2dad274-0d92-42fa-bf1e-a22af034211f", "name": "p1rdm172", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "85bcfea0-d3da-47ac-b484-16d7e9deb5ef"}}}}, {"uuid": "67b2edbf-fb9a-4042-9878-0abb256c07b4", "name": "", "x": 38.701284735816664, "y": -122.3767239154521, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4842819e-3f17-47da-a8bf-c3402c3c00b7", "name": "p1rlv161", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "67b2edbf-fb9a-4042-9878-0abb256c07b4"}}}}, {"uuid": "8faa352b-237f-48a0-9eeb-1ca7041e4a54", "name": "", "x": 38.701286056772844, "y": -122.37644037803527, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9872669f-fd85-458a-8951-ec12965fb42b", "name": "p1rdt82lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8faa352b-237f-48a0-9eeb-1ca7041e4a54"}}}}, {"uuid": "e2c58a52-518f-4c8c-9b38-b8662ad5ade7", "name": "", "x": 38.70116550444912, "y": -122.3763339478172, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "44bdfec0-2d44-442d-b562-ac786c61a76a", "name": "p1rdm173", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e2c58a52-518f-4c8c-9b38-b8662ad5ade7"}}}}, {"uuid": "c8e5702d-def0-482b-8f6a-0620e7bbbeff", "name": "", "x": 38.70118248419553, "y": -122.37613829900104, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b7538477-32ab-4db6-872d-83be7ec89fd9", "name": "p1rlv830", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c8e5702d-def0-482b-8f6a-0620e7bbbeff"}}}}, {"uuid": "3adcb55d-9b1a-46b3-b905-26ad4c6bff2d", "name": "", "x": 38.70185461418825, "y": -122.38682011107082, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8dac1e07-5eb6-4945-a3d9-95b77310358d", "name": "p1rdt83lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3adcb55d-9b1a-46b3-b905-26ad4c6bff2d"}}}}, {"uuid": "4a73fce2-8e99-4a9f-bc75-215c102dbda8", "name": "", "x": 38.702004410202626, "y": -122.38671135342908, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "471bad88-4514-4b02-aa1a-1d2aaa15557f", "name": "p1rlv163", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4a73fce2-8e99-4a9f-bc75-215c102dbda8"}}}}, {"uuid": "fbb96684-d951-42a4-a1f6-ce4c0c253377", "name": "", "x": 38.70161136737774, "y": -122.38394317395175, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d9de64e4-b140-4526-af3c-1f7ceaa687bf", "name": "p1rdm175", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fbb96684-d951-42a4-a1f6-ce4c0c253377"}}}}, {"uuid": "5a097ffc-12e8-463a-bd24-dd8185e42490", "name": "", "x": 38.701999398350054, "y": -122.38404334662313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9e7880c9-0932-4395-abf9-2274e400f280", "name": "p1rlv165", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5a097ffc-12e8-463a-bd24-dd8185e42490"}}}}, {"uuid": "61710186-ca37-4767-9c87-d70a0b168e59", "name": "", "x": 38.70158970365277, "y": -122.38378988145172, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bdb8aaf1-0e21-42e0-a72d-666646561235", "name": "p1rdt84lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "61710186-ca37-4767-9c87-d70a0b168e59"}}}}, {"uuid": "5d8a0ae0-27e3-4461-b370-f4c1e51c40dd", "name": "", "x": 38.701645776351214, "y": -122.38363237450628, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8a6bf0b9-809d-48fb-b8bd-375df052b6cc", "name": "p1rdm176", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5d8a0ae0-27e3-4461-b370-f4c1e51c40dd"}}}}, {"uuid": "209596cf-c99f-4561-a520-381ebd08802a", "name": "", "x": 38.70187142242643, "y": -122.3836994386808, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "21d333f7-7426-4fa6-8ab2-c6118055ece1", "name": "p1rlv166", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "209596cf-c99f-4561-a520-381ebd08802a"}}}}, {"uuid": "a079cab2-18b3-4986-9bd6-e862df6a3992", "name": "", "x": 38.70159534277448, "y": -122.37751697598218, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "40f4034e-c735-419b-80cd-d729d75f4692", "name": "p1rdt85lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a079cab2-18b3-4986-9bd6-e862df6a3992"}}}}, {"uuid": "d5be180e-e603-44df-91b2-15bf09529aaa", "name": "", "x": 38.70142358074945, "y": -122.3774127173029, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "470fe3ed-5b24-438a-ba6d-cdd9f774e5ad", "name": "p1rlv168", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d5be180e-e603-44df-91b2-15bf09529aaa"}}}}, {"uuid": "9ad1b5f7-6de7-45a6-82fa-a019f2a2d2dd", "name": "", "x": 38.69187926915615, "y": -122.40371977394915, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29", "name": "p1rdt89lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9ad1b5f7-6de7-45a6-82fa-a019f2a2d2dd"}}}}, {"uuid": "2dcf3d7d-5bad-4a2a-89df-cc749726edb1", "name": "", "x": 38.69174128032129, "y": -122.40438031441046, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1186295-59ff-48a8-b31d-0f7cd40df1ab", "name": "p1rlv174", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2dcf3d7d-5bad-4a2a-89df-cc749726edb1"}}}}, {"uuid": "b8b95dc9-b571-48bb-b6a5-505568391f8f", "name": "", "x": 38.69209810103375, "y": -122.40366444006949, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "905e9287-bdb6-44e0-b0af-f59ab4ad4d8e", "name": "p1rlv175", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b8b95dc9-b571-48bb-b6a5-505568391f8f"}}}}, {"uuid": "fd83f614-e9b0-4c57-8f6b-38f4f1283fb9", "name": "", "x": 38.69217885130816, "y": -122.4035947777604, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "931c8cee-89fe-447d-8788-af1e5f9f8775", "name": "p1rlv176", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fd83f614-e9b0-4c57-8f6b-38f4f1283fb9"}}}}, {"uuid": "d368bf8f-c6cb-4bf9-ac2a-89d02da7ed90", "name": "", "x": 38.6915327307124, "y": -122.40412907570833, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "090d6084-5cc6-473d-99c0-a6309571d633", "name": "p1rlv177", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d368bf8f-c6cb-4bf9-ac2a-89d02da7ed90"}}}}, {"uuid": "f010dad3-54f5-452e-a9dc-a82317b93f0f", "name": "", "x": 38.69192571259695, "y": -122.40343589909303, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a9debf70-62f4-4870-ad8b-bffc4bc4ad3f", "name": "p1rlv178", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f010dad3-54f5-452e-a9dc-a82317b93f0f"}}}}, {"uuid": "3b0576c8-db7c-411b-9c1c-bfa9f59cbb2b", "name": "", "x": 38.69194238589858, "y": -122.40317129254535, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fb03260b-d7d7-4779-ab2c-37c9a1e34d66", "name": "p1rlv179", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3b0576c8-db7c-411b-9c1c-bfa9f59cbb2b"}}}}, {"uuid": "1d052612-64a8-4667-9de7-cadc1ee125d3", "name": "", "x": 38.690562886551874, "y": -122.39178515337943, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d156fdde-5620-4a6f-b8c1-a3ab986fcc88", "name": "p1rdt150lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d052612-64a8-4667-9de7-cadc1ee125d3"}}}}, {"uuid": "30a89bc3-9ed4-40c7-9ecb-6c588b8c5880", "name": "", "x": 38.69053687920906, "y": -122.3917425303033, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8d3a86df-2ac5-4959-b857-562795ce84ba", "name": "p1rlv285", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "30a89bc3-9ed4-40c7-9ecb-6c588b8c5880"}}}}, {"uuid": "53d8affc-2792-4637-a447-6a4e58c78313", "name": "", "x": 38.66809150084286, "y": -122.48424417400362, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d64d858-a9f7-430f-890e-a456f8913c30", "name": "p1rdt177lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "53d8affc-2792-4637-a447-6a4e58c78313"}}}}, {"uuid": "7607cd8e-f257-4a6d-b55c-9a898d29baf6", "name": "", "x": 38.66811702312487, "y": -122.4842010892547, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "57b88281-b728-4779-82b1-4cc9eb4b41b1", "name": "p1rlv337", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7607cd8e-f257-4a6d-b55c-9a898d29baf6"}}}}, {"uuid": "de0c745d-5ced-43d0-9095-ed76c1548f39", "name": "", "x": 38.681876674272594, "y": -122.49390622766961, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b3314fa8-a838-4028-abb5-043425fd0785", "name": "p1rdt178lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "de0c745d-5ced-43d0-9095-ed76c1548f39"}}}}, {"uuid": "81b033cd-6820-4e9d-9d4a-fe4406f73e5e", "name": "", "x": 38.68190220002097, "y": -122.49386313799357, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e6b2aba6-a289-4a50-a131-2064047d1341", "name": "p1rlv338", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "81b033cd-6820-4e9d-9d4a-fe4406f73e5e"}}}}, {"uuid": "a7b6930a-f33e-4110-8b61-e7e73d1f1ddc", "name": "", "x": 38.66898414531813, "y": -122.45869594003535, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c3e633bc-311e-4698-a413-9c6cf09c42a8", "name": "p1rdt180lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a7b6930a-f33e-4110-8b61-e7e73d1f1ddc"}}}}, {"uuid": "6b1f1532-b5d7-4977-bb8a-eeb24a23de79", "name": "", "x": 38.66899849994981, "y": -122.45874675513116, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bb4797d6-b46e-4058-8985-d9f4b660f0a7", "name": "p1rlv340", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6b1f1532-b5d7-4977-bb8a-eeb24a23de79"}}}}, {"uuid": "ea35ba17-1f44-4509-80ca-f02601f3838a", "name": "", "x": 38.75302665769167, "y": -122.36662619401973, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "05401825-91f8-41f8-9204-ab5806458594", "name": "p1rdt181lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea35ba17-1f44-4509-80ca-f02601f3838a"}}}}, {"uuid": "53a2fe42-5fec-4c3f-bb86-47337d445449", "name": "", "x": 38.75299240671526, "y": -122.36643483348682, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "54f0ea2c-3849-4ff0-ad8c-e3f65515d178", "name": "p1rlv341", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "53a2fe42-5fec-4c3f-bb86-47337d445449"}}}}, {"uuid": "d7210e3a-8ceb-4042-887e-2baf51dd5726", "name": "", "x": 38.75309371224946, "y": -122.36683673194118, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "13754fdb-4039-49fb-b584-8437191dfb2b", "name": "p1rlv342", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d7210e3a-8ceb-4042-887e-2baf51dd5726"}}}}, {"uuid": "953e5e3a-8f85-4748-8249-0703ee775dc5", "name": "", "x": 38.67877405858776, "y": -122.47520020508532, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "db407ddd-fb81-4767-99e1-9aeab12fc770", "name": "p1rdt182lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "953e5e3a-8f85-4748-8249-0703ee775dc5"}}}}, {"uuid": "2f6bbaf5-24aa-40e8-b566-845c59a445a2", "name": "", "x": 38.6787480814273, "y": -122.47515755839895, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0197ef22-9f8f-48a9-84de-663a7ce22773", "name": "p1rlv343", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2f6bbaf5-24aa-40e8-b566-845c59a445a2"}}}}, {"uuid": "35e5b909-f634-4a8b-b66b-4e8bede0808f", "name": "", "x": 38.68506507552232, "y": -122.35588924552482, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4724ea16-dc31-48f8-98b8-b9a223e9a4bb", "name": "p1rdt209lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "35e5b909-f634-4a8b-b66b-4e8bede0808f"}}}}, {"uuid": "1ba1a288-120a-4dbf-bfb8-42f4858ad738", "name": "", "x": 38.68512263068088, "y": -122.3560076800405, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7e1ea241-5329-4db5-996a-df09a9c25687", "name": "p1rlv377", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1ba1a288-120a-4dbf-bfb8-42f4858ad738"}}}}, {"uuid": "4df59d4a-6893-4f1b-b48e-0db3cf09f7af", "name": "", "x": 38.68504927407323, "y": -122.35577838786406, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "50225dcf-40bc-44b5-9dec-072ac5b2334e", "name": "p1rlv379", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4df59d4a-6893-4f1b-b48e-0db3cf09f7af"}}}}, {"uuid": "1885af1b-3bcd-4472-8d94-a5c3f52eb2c6", "name": "", "x": 38.684623418522186, "y": -122.35792952524736, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "05f6a3bf-d465-4f16-8205-616d1f4dd465", "name": "p1rdt210lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1885af1b-3bcd-4472-8d94-a5c3f52eb2c6"}}}}, {"uuid": "61baa391-c9f5-4078-ac02-6dd3b54a83b1", "name": "", "x": 38.684597398947716, "y": -122.35788691809313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d3ff63a0-bf3f-43b0-807c-935467b4fe46", "name": "p1rlv378", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "61baa391-c9f5-4078-ac02-6dd3b54a83b1"}}}}, {"uuid": "10baed55-38a3-44cd-93db-649b00e85837", "name": "", "x": 38.68355474726837, "y": -122.35674337268465, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1d5af6ce-9a4c-414a-bbd8-15d82f50cb57", "name": "p1rdt211lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10baed55-38a3-44cd-93db-649b00e85837"}}}}, {"uuid": "08ef91ea-1f5d-4f98-98c3-eb8f6fa34493", "name": "", "x": 38.68358022206023, "y": -122.35670023394748, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0ee07ef9-b7b0-4457-be1c-78e754dbcfc7", "name": "p1rlv380", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "08ef91ea-1f5d-4f98-98c3-eb8f6fa34493"}}}}, {"uuid": "16164883-d887-47fc-aabd-993c8668dba9", "name": "", "x": 38.70346378054364, "y": -122.37754850885149, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "591461d4-20da-4165-a210-4dbaedd81016", "name": "p1rdt233lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "16164883-d887-47fc-aabd-993c8668dba9"}}}}, {"uuid": "646ac96d-cdc9-49c3-a0f1-3ae8e77da6b9", "name": "", "x": 38.703632263710084, "y": -122.37756607257536, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b54aae8-5a94-4e04-882f-748e1c5f1390", "name": "p1rlv415", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "646ac96d-cdc9-49c3-a0f1-3ae8e77da6b9"}}}}, {"uuid": "6c429ce0-0fef-418f-9d71-d67238478aa4", "name": "", "x": 38.70329902987842, "y": -122.37760346268222, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "99abc7dc-8e15-420f-9bc9-0e6229d4dab3", "name": "p1rlv416", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c429ce0-0fef-418f-9d71-d67238478aa4"}}}}, {"uuid": "9497beca-f842-4ee6-a8e5-508ab4b0b459", "name": "", "x": 38.70344498505631, "y": -122.37793571026356, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "019c88af-413c-4331-84f7-923a1df0a303", "name": "p1rdm434", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9497beca-f842-4ee6-a8e5-508ab4b0b459"}}}}, {"uuid": "0262bf06-9770-4733-99e9-cf98f80a689b", "name": "", "x": 38.703688840272775, "y": -122.37803710181561, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6b33ed36-116b-4741-9374-6927bd537427", "name": "p1rlv412", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0262bf06-9770-4733-99e9-cf98f80a689b"}}}}, {"uuid": "32ce07e1-cf47-4abf-b3bf-24f51f6cfdb1", "name": "", "x": 38.703449772341166, "y": -122.3771421382582, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e3b3eb51-c011-4f2c-8a10-c43c9c86217b", "name": "p1rdm437", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "32ce07e1-cf47-4abf-b3bf-24f51f6cfdb1"}}}}, {"uuid": "294366aa-f7eb-4e04-8d91-2eceb5798884", "name": "", "x": 38.70363888674939, "y": -122.37711749672587, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e7935b9c-b631-432c-a322-9beea73f1fc4", "name": "p1rlv419", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "294366aa-f7eb-4e04-8d91-2eceb5798884"}}}}, {"uuid": "6bcfb4f6-2e39-4863-80fb-e741b4350228", "name": "", "x": 38.70342206460632, "y": -122.37701587380883, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1a713d96-e13f-447e-ab9f-012af3e26afe", "name": "p1rdm438", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6bcfb4f6-2e39-4863-80fb-e741b4350228"}}}}, {"uuid": "d9702311-ea42-4ddf-ae4e-121430adc593", "name": "", "x": 38.703538904912854, "y": -122.37695735772205, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be4d7ed8-5ddd-4127-87ab-eb3f48a580c2", "name": "p1rlv420", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d9702311-ea42-4ddf-ae4e-121430adc593"}}}}, {"uuid": "ad647b8c-5c1a-41de-9194-421c09929204", "name": "", "x": 38.70315939892254, "y": -122.38015776111975, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "adb2d039-e162-43f7-8498-1374581a75fc", "name": "p1rdm439", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ad647b8c-5c1a-41de-9194-421c09929204"}}}}, {"uuid": "760681c9-084f-4e36-a61d-5f3745e7cd14", "name": "", "x": 38.70329481206863, "y": -122.38020259377379, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8408ac87-a086-46bc-9d88-cca79e17dd62", "name": "p1rlv413", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "760681c9-084f-4e36-a61d-5f3745e7cd14"}}}}, {"uuid": "d0c778bc-b90c-47b5-8172-39b840e24616", "name": "", "x": 38.70311258602368, "y": -122.38036119573296, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e480f304-b192-4107-91e1-131d481657b2", "name": "p1rdt234lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d0c778bc-b90c-47b5-8172-39b840e24616"}}}}, {"uuid": "dcdc577e-1e4f-42be-b252-c5958b06d753", "name": "", "x": 38.7029185925103, "y": -122.38063135468911, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "84570b2e-efeb-477e-be1c-43b9d2922fda", "name": "p1rdm440", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dcdc577e-1e4f-42be-b252-c5958b06d753"}}}}, {"uuid": "3fe19806-a4a8-4e42-a1c2-255007fc068e", "name": "", "x": 38.7029199228882, "y": -122.38034781076358, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "49dbdd44-a36a-46b5-aef8-558ef7693315", "name": "p1rlv417", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3fe19806-a4a8-4e42-a1c2-255007fc068e"}}}}, {"uuid": "f7a94d2a-3acd-4984-af0d-c281cf5c686d", "name": "", "x": 38.702857286057856, "y": -122.38150193355499, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d8a6708a-d098-4e02-aac6-4aba7fdc71a5", "name": "p1rdt235lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f7a94d2a-3acd-4984-af0d-c281cf5c686d"}}}}, {"uuid": "25aebc37-4fc6-4413-8a7a-b0c4254ee4f0", "name": "", "x": 38.70300468515236, "y": -122.38157364260027, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "12dcb168-1bfe-448b-8d9a-f5cb4c61aafe", "name": "p1rlv421", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "25aebc37-4fc6-4413-8a7a-b0c4254ee4f0"}}}}, {"uuid": "deb1598d-1ec1-41d1-8f30-df41804e8290", "name": "", "x": 38.70336335384591, "y": -122.37836945726418, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7dd709e3-c5ec-4a01-8297-11f4d1261c3a", "name": "p1rdt236lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "deb1598d-1ec1-41d1-8f30-df41804e8290"}}}}, {"uuid": "4713b3a2-a889-4ee0-b304-c3718091deae", "name": "", "x": 38.70357389491814, "y": -122.3784521142025, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aa7bb51b-8ba8-4a05-872a-7f5ce084fe88", "name": "p1rlv422", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4713b3a2-a889-4ee0-b304-c3718091deae"}}}}, {"uuid": "299ac3a7-1294-41c6-bdfe-f81fcbac0440", "name": "", "x": 38.70326683877779, "y": -122.37832826777388, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6c1e9680-f7de-497c-953a-54f4db2899e2", "name": "p1rlv423", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "299ac3a7-1294-41c6-bdfe-f81fcbac0440"}}}}, {"uuid": "69492088-1302-4501-8eb1-50d1ab439d19", "name": "", "x": 38.69944370500361, "y": -122.41580872476209, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b72726f3-250c-4d98-86bc-5120137bd0f1", "name": "p1rdt237lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "69492088-1302-4501-8eb1-50d1ab439d19"}}}}, {"uuid": "98d78dd8-503b-4dca-8dd9-5465a16c50ee", "name": "", "x": 38.69954841432615, "y": -122.41568889821919, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e1a91c8c-aabd-4fad-8306-908f186a5744", "name": "p1rlv424", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "98d78dd8-503b-4dca-8dd9-5465a16c50ee"}}}}, {"uuid": "85c0e239-6490-4ec7-87dd-d66b31f76a42", "name": "", "x": 38.69927637037365, "y": -122.4159171313363, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "753035df-8705-48eb-92b3-c4bef603b66b", "name": "p1rlv449", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "85c0e239-6490-4ec7-87dd-d66b31f76a42"}}}}, {"uuid": "9558861f-5a1b-4bd9-ba31-559c8aa3081b", "name": "", "x": 38.70680842002751, "y": -122.42486556791981, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "42dff28c-89e7-4b56-bf23-3dcdd3ca216f", "name": "p1rdt251lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9558861f-5a1b-4bd9-ba31-559c8aa3081b"}}}}, {"uuid": "e1935b1d-1c47-4379-ae94-01784a6da9a1", "name": "", "x": 38.70631853264042, "y": -122.42524857112629, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2f771660-4dad-43df-b38b-7da5f6180a25", "name": "p1rlv439", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e1935b1d-1c47-4379-ae94-01784a6da9a1"}}}}, {"uuid": "dee0ea3a-c26d-4a97-b33b-933c3b68df0b", "name": "", "x": 38.70720720644569, "y": -122.42453989136035, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0d665758-71e1-4478-b39d-671f78f623e5", "name": "p1rlv445", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dee0ea3a-c26d-4a97-b33b-933c3b68df0b"}}}}, {"uuid": "ce5d7daa-a960-4160-80bd-5a74b7ce65ff", "name": "", "x": 38.70744608256419, "y": -122.42546956600445, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "acce3105-f519-491c-921a-df1294795742", "name": "p1rlv446", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ce5d7daa-a960-4160-80bd-5a74b7ce65ff"}}}}, {"uuid": "29f44b7f-784a-4c81-83d9-75ac5e82c9e1", "name": "", "x": 38.70608276722945, "y": -122.42495143556884, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "042873fa-10df-4de0-a040-ac429b8bf7d9", "name": "p1rlv447", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "29f44b7f-784a-4c81-83d9-75ac5e82c9e1"}}}}, {"uuid": "5305ea3c-176d-4627-80b2-70f68e3b3249", "name": "", "x": 38.70711624377896, "y": -122.42436810473787, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4bb83d65-630d-4f1d-8e3d-8937a5a05524", "name": "p1rlv448", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5305ea3c-176d-4627-80b2-70f68e3b3249"}}}}, {"uuid": "8c2a657b-ca27-44ca-9109-2bc7768188c8", "name": "", "x": 38.78777229039905, "y": -122.347029423475, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "704fece3-3b83-4c0b-bcd1-d463b3cdaf6b", "name": "p1rdt253lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8c2a657b-ca27-44ca-9109-2bc7768188c8"}}}}, {"uuid": "793f6ac1-bd76-48ee-b6b1-d7f4fea5c5fb", "name": "", "x": 38.78740834836766, "y": -122.34691362308135, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0a778b00-482c-4b81-8213-f17202a105fa", "name": "p1rlv441", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "793f6ac1-bd76-48ee-b6b1-d7f4fea5c5fb"}}}}, {"uuid": "c229e0d5-b101-4f6e-b560-2f2e9acc9bab", "name": "", "x": 38.78809447859801, "y": -122.3471376433436, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "30f29674-3083-4da2-95e2-a1f11a7eb7f8", "name": "p1rlv444", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c229e0d5-b101-4f6e-b560-2f2e9acc9bab"}}}}, {"uuid": "41ca8386-0452-4bf9-be70-2fadb63707ca", "name": "", "x": 38.706805740104386, "y": -122.42594225497479, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "655d8f44-aa2f-4548-a1ca-83fcce9fa7aa", "name": "p1rdt254lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "41ca8386-0452-4bf9-be70-2fadb63707ca"}}}}, {"uuid": "3c269399-d74c-4d59-a8d2-dafb03efc520", "name": "", "x": 38.70689780217361, "y": -122.42576147929557, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6cd667a9-c0ef-49ce-b6ee-7e474d9ae761", "name": "p1rlv442", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3c269399-d74c-4d59-a8d2-dafb03efc520"}}}}, {"uuid": "e57dd29b-9cd7-424b-a501-9ee3096a6870", "name": "", "x": 38.706755483647314, "y": -122.4261421504902, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c2100c17-c0e6-47e9-87f8-72016b22dd4b", "name": "p1rlv443", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e57dd29b-9cd7-424b-a501-9ee3096a6870"}}}}, {"uuid": "538a31a7-d921-47e6-9d70-ef1da95cfcb4", "name": "", "x": 38.68872418378523, "y": -122.3484131511325, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e4c28500-44f7-47c6-b8a8-d1e3468494e3", "name": "p1rdt257lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "538a31a7-d921-47e6-9d70-ef1da95cfcb4"}}}}, {"uuid": "7d61257b-f6a2-48da-9a96-61fb9f4ca7c8", "name": "", "x": 38.68876626401415, "y": -122.34840879300008, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bb46f1ae-0cdb-45d1-b389-639cdf345f8e", "name": "p1rlv452", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7d61257b-f6a2-48da-9a96-61fb9f4ca7c8"}}}}, {"uuid": "80be5501-4a72-4a0b-a037-72d42ecb1ebd", "name": "", "x": 38.69599975733859, "y": -122.39252773638533, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ad9ffaef-f21b-43da-9f67-3a8271edb6bd", "name": "p1rdt258lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "80be5501-4a72-4a0b-a037-72d42ecb1ebd"}}}}, {"uuid": "98e49797-c26c-470d-af4f-29283772b7f7", "name": "", "x": 38.695944209864116, "y": -122.39278871278485, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f6a8a3c7-5165-48b7-8233-30d3af045442", "name": "p1rlv453", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "98e49797-c26c-470d-af4f-29283772b7f7"}}}}, {"uuid": "f90c9866-5b26-4071-a4fc-b0a7d6c52f2d", "name": "", "x": 38.69600232943997, "y": -122.39183378308958, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "85f0d94e-c096-4d53-ae05-f0dc59f73d02", "name": "p1rlv456", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f90c9866-5b26-4071-a4fc-b0a7d6c52f2d"}}}}, {"uuid": "de4f8fed-9482-452a-90c9-5e7caec23923", "name": "", "x": 38.69599911358809, "y": -122.39294923817128, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "76b212f9-2e27-4064-a2c5-079786afb1d1", "name": "p1rlv460", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "de4f8fed-9482-452a-90c9-5e7caec23923"}}}}, {"uuid": "54918463-a6a7-4a05-bf52-c9011253cbfc", "name": "", "x": 38.68471814126827, "y": -122.36995372008337, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c6a0feb3-78c1-4d69-8d18-2a8c3abdcf54", "name": "p1rdt259lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "54918463-a6a7-4a05-bf52-c9011253cbfc"}}}}, {"uuid": "661f61fe-a47e-42bd-9f59-20f5526dc5b4", "name": "", "x": 38.684738584166, "y": -122.36987703423111, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3493b0ed-43a2-4602-a7ad-a817331c9d8e", "name": "p1rlv454", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "661f61fe-a47e-42bd-9f59-20f5526dc5b4"}}}}, {"uuid": "9a532ae9-3d3d-4204-b6db-339efb98c7a9", "name": "", "x": 38.68473945129645, "y": -122.37003799082656, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "552153cc-f5be-42ee-9985-9361c2e7e2a1", "name": "p1rlv455", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9a532ae9-3d3d-4204-b6db-339efb98c7a9"}}}}, {"uuid": "02d1b4b0-73de-4ac2-9167-0f91c0a87843", "name": "", "x": 38.69417505217448, "y": -122.39691277672273, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d8d796d8-6750-4ca5-ae07-1b07331ce6ee", "name": "p1rdt260lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "02d1b4b0-73de-4ac2-9167-0f91c0a87843"}}}}, {"uuid": "c2a504be-9d17-43d9-a528-ac7860584549", "name": "", "x": 38.69444988952913, "y": -122.39658452058625, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ec66e302-748d-4300-ba65-719de0a906bb", "name": "p1rlv458", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c2a504be-9d17-43d9-a528-ac7860584549"}}}}, {"uuid": "3faab6eb-e94a-4a73-8298-c56a3209c291", "name": "", "x": 38.69489061384813, "y": -122.39641983065454, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "76dd0f1b-4109-4707-a547-f0ab1b6e148f", "name": "p1rlv461", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3faab6eb-e94a-4a73-8298-c56a3209c291"}}}}, {"uuid": "e28b20ea-136d-493a-b93f-1d8c8d2e0275", "name": "", "x": 38.69609340912066, "y": -122.39266578758262, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fe4ec5b6-61fb-4b66-9e43-19d81af88966", "name": "p1rdt261lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e28b20ea-136d-493a-b93f-1d8c8d2e0275"}}}}, {"uuid": "32b9738c-437a-49e1-bcf9-ba63fbef1757", "name": "", "x": 38.69613569697208, "y": -122.39266409008623, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4c112196-bcbc-41bc-99a9-f3657c335c7a", "name": "p1rlv459", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "32b9738c-437a-49e1-bcf9-ba63fbef1757"}}}}, {"uuid": "fc0b9de9-847e-4f4c-9650-639faab16240", "name": "", "x": 38.69746455104433, "y": -122.39109295618859, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "30952601-1479-4770-9b77-9fe3465310b7", "name": "p1rdt262lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fc0b9de9-847e-4f4c-9650-639faab16240"}}}}, {"uuid": "4bce323d-cade-48f6-bd80-19de38309d9c", "name": "", "x": 38.697566588571334, "y": -122.39110756675504, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9176da24-7eb5-4b0b-99dd-886c3f974798", "name": "p1rlv462", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4bce323d-cade-48f6-bd80-19de38309d9c"}}}}, {"uuid": "614237e9-0299-4752-b3bd-ac572efbc93f", "name": "", "x": 38.69741333633857, "y": -122.39109736665547, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "895d0235-3ee6-4f06-9978-9d615d721ebd", "name": "p1rlv464", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "614237e9-0299-4752-b3bd-ac572efbc93f"}}}}, {"uuid": "85ef6f5a-7f9c-417e-a030-2cddbc51d968", "name": "", "x": 38.69796207835795, "y": -122.39189498505252, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2c7501f4-0394-4766-a3c5-b17fda7f3817", "name": "p1rdt263lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "85ef6f5a-7f9c-417e-a030-2cddbc51d968"}}}}, {"uuid": "020235d3-cf73-4472-bd30-ddd25a084052", "name": "", "x": 38.69793607105191, "y": -122.39185235758016, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ff9d9cca-1878-478d-a190-b58c9098f13e", "name": "p1rlv463", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "020235d3-cf73-4472-bd30-ddd25a084052"}}}}, {"uuid": "a47e9ee1-03b2-4ff9-935d-f8a781ece2cd", "name": "", "x": 38.7505574694735, "y": -122.41550076869619, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d33a03d6-fddc-4e47-8018-cd7d290b30b0", "name": "p1rdt270lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a47e9ee1-03b2-4ff9-935d-f8a781ece2cd"}}}}, {"uuid": "dbb5ba0e-ba1e-4371-bcd8-6e1f788e6252", "name": "", "x": 38.75057184305653, "y": -122.41555163249289, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2e589527-d388-4364-87d2-2f4af1a14509", "name": "p1rlv474", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dbb5ba0e-ba1e-4371-bcd8-6e1f788e6252"}}}}, {"uuid": "18d6fe25-b7b6-445a-ae4b-e251280306d0", "name": "", "x": 38.77190208512443, "y": -122.36444610004378, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6715c6a-6869-412a-8e59-e5c2eb03c56b", "name": "p1rdt275lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "18d6fe25-b7b6-445a-ae4b-e251280306d0"}}}}, {"uuid": "f5d52a4c-e524-4515-8bd6-5a25557f9ba1", "name": "", "x": 38.77188833047837, "y": -122.36449725722824, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cb55ec0b-b6f7-48a7-8dae-dda95fc34499", "name": "p1rlv480", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5d52a4c-e524-4515-8bd6-5a25557f9ba1"}}}}, {"uuid": "e49c6293-1f6d-43c7-9f99-3bad9fb91f2e", "name": "", "x": 38.6981164551154, "y": -122.40319272296294, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b478b4f8-8d5e-47b0-a56a-8b991dc8d944", "name": "p1rdt276lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e49c6293-1f6d-43c7-9f99-3bad9fb91f2e"}}}}, {"uuid": "c92307a0-d75e-4ba8-8c7a-0fc694691602", "name": "", "x": 38.69831357847344, "y": -122.40315284432228, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8d9e77ad-42c6-4413-96e6-debfed3c442a", "name": "p1rlv481", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c92307a0-d75e-4ba8-8c7a-0fc694691602"}}}}, {"uuid": "78102e48-a7be-4d96-894e-01561d3adb23", "name": "", "x": 38.697080868964996, "y": -122.39900074624246, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "24486e15-ff1e-45b3-aa02-703263f04844", "name": "p1rdt277lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "78102e48-a7be-4d96-894e-01561d3adb23"}}}}, {"uuid": "4daf40d1-d481-436a-ab75-fc0ab9938839", "name": "", "x": 38.696472678672315, "y": -122.39914337613104, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8d4b708f-cc15-4ee3-87e0-4d26fec02f1e", "name": "p1rlv482", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4daf40d1-d481-436a-ab75-fc0ab9938839"}}}}, {"uuid": "7a0f4694-1f59-45db-ac24-c397b84f74bf", "name": "", "x": 38.682836254431685, "y": -122.35413994526482, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a8af5824-d5d7-4cba-98b7-d72993909f22", "name": "p1rdt278lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7a0f4694-1f59-45db-ac24-c397b84f74bf"}}}}, {"uuid": "ae9edf40-7cf8-4a90-b1fb-e195a11a717e", "name": "", "x": 38.682850654364266, "y": -122.35419074861349, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d059a618-6f09-404b-b1a0-0e7aa0c55c45", "name": "p1rlv483", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ae9edf40-7cf8-4a90-b1fb-e195a11a717e"}}}}, {"uuid": "5e812994-8ece-4fc5-8b76-348599a6e2ce", "name": "", "x": 38.696321369018115, "y": -122.40303140946239, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2d6856ee-d113-45ec-99e0-8a915a89a56c", "name": "p1rdm508", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5e812994-8ece-4fc5-8b76-348599a6e2ce"}}}}, {"uuid": "b52b0521-4625-42cf-a321-7a6ef164fc92", "name": "", "x": 38.6966231134774, "y": -122.40212045173747, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fde62b60-c5f6-44d6-b2f2-211c21b02033", "name": "p1rlv484", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b52b0521-4625-42cf-a321-7a6ef164fc92"}}}}, {"uuid": "ef878753-5b7b-4b1e-adac-6f6766e7a2bf", "name": "", "x": 38.69619520198978, "y": -122.40301175619707, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4bf679fe-712f-4db6-9df9-debb29b7ee73", "name": "p1rdt279lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef878753-5b7b-4b1e-adac-6f6766e7a2bf"}}}}, {"uuid": "38f0df30-9996-4460-baaf-8cf45c0bdea2", "name": "", "x": 38.69610445115518, "y": -122.40290672048755, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9c3bf9bd-d12a-47d7-b2e2-3f31f3a0419b", "name": "p1rdm509", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "38f0df30-9996-4460-baaf-8cf45c0bdea2"}}}}, {"uuid": "6a1f742e-0281-41f8-a274-ca742d98c351", "name": "", "x": 38.69640566539714, "y": -122.40189227549035, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f8d2c379-7e19-46c4-8c6e-533fa9db7764", "name": "p1rlv485", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a1f742e-0281-41f8-a274-ca742d98c351"}}}}, {"uuid": "958a623e-a829-4d3b-b310-b6a20945b961", "name": "", "x": 38.762845986496735, "y": -122.35672935763573, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e4eafd2-0f68-4e2a-a62c-89cb877004d4", "name": "p1rdt280lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "958a623e-a829-4d3b-b310-b6a20945b961"}}}}, {"uuid": "13e2dd00-cffc-4b7a-8ed9-55c3876df7bd", "name": "", "x": 38.762552303891766, "y": -122.35627912797126, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a54b2228-9e7d-4e6b-939d-ab2765454522", "name": "p1rlv486", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "13e2dd00-cffc-4b7a-8ed9-55c3876df7bd"}}}}, {"uuid": "4ee1cc19-733f-450e-b658-7f8074b32937", "name": "", "x": 38.75426623013744, "y": -122.36483936695494, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3e01a56d-1bfc-4169-9c3e-1373f9dbeb38", "name": "p1rdt281lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ee1cc19-733f-450e-b658-7f8074b32937"}}}}, {"uuid": "63783525-ad46-428b-b194-e5e2392a991c", "name": "", "x": 38.754777075984755, "y": -122.36484236876056, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be2d5799-907e-46fd-a389-120aea352775", "name": "p1rlv487", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "63783525-ad46-428b-b194-e5e2392a991c"}}}}, {"uuid": "e050f717-a215-4406-852a-29b4e392e4c5", "name": "", "x": 38.7537136313869, "y": -122.3648287764951, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "97c38794-7c60-4ff8-b09b-7503c9604409", "name": "p1rlv523", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e050f717-a215-4406-852a-29b4e392e4c5"}}}}, {"uuid": "3f49fa54-5e18-452b-ac04-7e82caec4a6b", "name": "", "x": 38.723225529795435, "y": -122.41097744489697, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7a8430e1-656f-4fe2-a11b-00adf429d75d", "name": "p1rdt297lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3f49fa54-5e18-452b-ac04-7e82caec4a6b"}}}}, {"uuid": "800c1fd5-f75b-4ea4-8955-de1e60878b43", "name": "", "x": 38.72307124027624, "y": -122.41075789575113, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bef074be-aac4-4d82-a832-641729756802", "name": "p1rlv524", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "800c1fd5-f75b-4ea4-8955-de1e60878b43"}}}}, {"uuid": "40ccb968-5212-4fa6-8793-3d76b678e286", "name": "", "x": 38.72334331826878, "y": -122.41110077065662, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3ab8e220-faf9-4108-80f8-22d2fe326c3d", "name": "p1rlv526", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "40ccb968-5212-4fa6-8793-3d76b678e286"}}}}, {"uuid": "429e93d6-a631-4ce5-9c3c-aa5a0aa6cedf", "name": "", "x": 38.72448847815554, "y": -122.41245231274745, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33e93250-9c11-4650-9469-412129855857", "name": "p1rdt298lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "429e93d6-a631-4ce5-9c3c-aa5a0aa6cedf"}}}}, {"uuid": "0688d8cc-a312-4660-8627-495ceab33df7", "name": "", "x": 38.72453056079826, "y": -122.41244798967669, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a42f8b99-82c6-4c90-81ea-6ccb38eacfab", "name": "p1rlv525", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0688d8cc-a312-4660-8627-495ceab33df7"}}}}, {"uuid": "fab5aa33-d64c-4dcc-b8ff-14c2773f63ad", "name": "", "x": 38.670540900167985, "y": -122.47976645470963, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6353ab92-f66f-47d8-97ac-058cf030ff82", "name": "p1rdt303lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fab5aa33-d64c-4dcc-b8ff-14c2773f63ad"}}}}, {"uuid": "9eb06290-2b92-41e0-9020-16bf69db06ca", "name": "", "x": 38.67056642076858, "y": -122.47972336691173, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32a1d9d7-31c7-4def-88d4-e4d41bd21572", "name": "p1rlv531", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9eb06290-2b92-41e0-9020-16bf69db06ca"}}}}, {"uuid": "8fb02675-4391-4938-a19f-1fd47ec0ceda", "name": "", "x": 38.67227127773109, "y": -122.47626596196271, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6a22ac71-bf3a-4016-86ce-fb25f471be5b", "name": "p1rdt304lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8fb02675-4391-4938-a19f-1fd47ec0ceda"}}}}, {"uuid": "98e5c374-ce1a-433a-8af6-cdab22541808", "name": "", "x": 38.67217810662493, "y": -122.4762166840671, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1362feeb-2e2c-4dd1-9f49-239c952c6120", "name": "p1rlv532", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "98e5c374-ce1a-433a-8af6-cdab22541808"}}}}, {"uuid": "b1b16ed0-c803-4ef8-af4d-bcfbdb7bd045", "name": "", "x": 38.67233171369118, "y": -122.47630752878543, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1f79bc5f-375f-4ecd-b828-eb7b137d7cab", "name": "p1rlv533", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b1b16ed0-c803-4ef8-af4d-bcfbdb7bd045"}}}}, {"uuid": "98bbd597-db60-4a2a-8e22-d8fd7c316c09", "name": "", "x": 38.67073161586084, "y": -122.47582091564139, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "90948977-fe1a-43b3-a8a4-86c080ae4906", "name": "p1rdt305lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "98bbd597-db60-4a2a-8e22-d8fd7c316c09"}}}}, {"uuid": "7f11a1c9-7fc0-498c-a911-6ffb6fc8d6be", "name": "", "x": 38.67104039312592, "y": -122.47571918109917, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0eb7074c-0745-4089-9329-aa3495f9b460", "name": "p1rlv534", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7f11a1c9-7fc0-498c-a911-6ffb6fc8d6be"}}}}, {"uuid": "ce2d9c5a-57c3-4ef1-b7d9-f4624daa6515", "name": "", "x": 38.67049996143512, "y": -122.47578059875961, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9cc91945-564c-4ace-bb53-77150b107b41", "name": "p1rlv535", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ce2d9c5a-57c3-4ef1-b7d9-f4624daa6515"}}}}, {"uuid": "58063c7b-e265-41f6-9754-559892ab8f15", "name": "", "x": 38.6707171128322, "y": -122.47597443436533, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d2ea78a8-b9c5-4760-b153-51b45565069e", "name": "p1rlv536", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "58063c7b-e265-41f6-9754-559892ab8f15"}}}}, {"uuid": "3a81837a-b6e1-4684-9525-903af091b574", "name": "", "x": 38.671226697580636, "y": -122.49048662526606, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "53eba878-66fa-4d30-8af4-1f583abe5f16", "name": "p1rdt306lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3a81837a-b6e1-4684-9525-903af091b574"}}}}, {"uuid": "31601fbd-a6ef-4c97-97da-e3c1cee1ddcf", "name": "", "x": 38.67124103844962, "y": -122.49053744844569, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9f2dfc9e-0b72-4465-b46a-d4e2a7a08f64", "name": "p1rlv537", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "31601fbd-a6ef-4c97-97da-e3c1cee1ddcf"}}}}, {"uuid": "1447dd15-b11d-4b92-aee8-fa7c9a86ea06", "name": "", "x": 38.685116671576026, "y": -122.45208329969167, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b8e448ea-e66d-4e16-80c0-8e742d7cac55", "name": "p1rdt335lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1447dd15-b11d-4b92-aee8-fa7c9a86ea06"}}}}, {"uuid": "20dab0fc-7fd8-4fca-bbe2-8c2946d2e18d", "name": "", "x": 38.68493681955931, "y": -122.45218585265648, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75628d41-a82d-4425-8aa2-9f377c771a4c", "name": "p1rlv588", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "20dab0fc-7fd8-4fca-bbe2-8c2946d2e18d"}}}}, {"uuid": "e11e5579-8701-4498-9418-0b99d6060f71", "name": "", "x": 38.6854049831095, "y": -122.45209030229843, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7a1c60be-f1a1-48d6-b396-4cca6d8c4e62", "name": "p1rlv589", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e11e5579-8701-4498-9418-0b99d6060f71"}}}}, {"uuid": "d9e96ec4-e74e-4618-9ee7-65d34c892888", "name": "", "x": 38.685061363444774, "y": -122.45183997708463, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "81ce208e-7244-418a-9867-b55b95ba0716", "name": "p1rlv590", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d9e96ec4-e74e-4618-9ee7-65d34c892888"}}}}, {"uuid": "10862e71-ec7d-4875-839a-324f8b84aa90", "name": "", "x": 38.68749417205864, "y": -122.45093337637859, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35993388-185f-4d1d-9dcb-16eb7556728f", "name": "p1rdt374lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10862e71-ec7d-4875-839a-324f8b84aa90"}}}}, {"uuid": "5987b6b3-bd40-4102-a885-a2b6b4a0a8d3", "name": "", "x": 38.687468186113925, "y": -122.45089073343217, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6e58890e-e6ce-4dda-91c0-5ccfdb5c420d", "name": "p1rlv657", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5987b6b3-bd40-4102-a885-a2b6b4a0a8d3"}}}}, {"uuid": "4b47f1f1-e215-42c1-aa5a-82bd5ed4ed38", "name": "", "x": 38.687021635585204, "y": -122.45201778533264, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d354e81e-b007-4bbe-b1db-50d7afacd0e0", "name": "p1rdt376lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4b47f1f1-e215-42c1-aa5a-82bd5ed4ed38"}}}}, {"uuid": "540e4606-3bc9-471d-b851-891dddd4bfbf", "name": "", "x": 38.68703599315794, "y": -122.452068611773, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "15751ee2-6783-472f-ad57-ec978234fec4", "name": "p1rlv660", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "540e4606-3bc9-471d-b851-891dddd4bfbf"}}}}, {"uuid": "b09e519e-2b26-438c-b80c-dc0e164fea9c", "name": "", "x": 38.67908332659903, "y": -122.51991969614502, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8569c197-174f-46ef-96c2-e0c674d7b046", "name": "p1rdt383lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b09e519e-2b26-438c-b80c-dc0e164fea9c"}}}}, {"uuid": "35e022ae-36d9-4824-88d4-cf5c8316580d", "name": "", "x": 38.67905736564, "y": -122.51987703293702, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eb25bf05-ce7f-405a-8c17-fd166748f7d3", "name": "p1rlv672", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "35e022ae-36d9-4824-88d4-cf5c8316580d"}}}}, {"uuid": "72ad716e-f1d2-48f5-a747-b3d15a844fd9", "name": "", "x": 38.679023967859024, "y": -122.52913908431695, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c56b4839-f007-4c9b-93a7-9147399f983f", "name": "p1rdt384lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "72ad716e-f1d2-48f5-a747-b3d15a844fd9"}}}}, {"uuid": "4cc9de64-df79-4551-84a0-ef1dbd2fec0c", "name": "", "x": 38.67837935182842, "y": -122.52878337051408, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "31d3267c-7020-4660-9a0b-49cd9d94a5d0", "name": "p1rlv673", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4cc9de64-df79-4551-84a0-ef1dbd2fec0c"}}}}, {"uuid": "17902503-2dce-426d-8ec3-66c36f03f7c9", "name": "", "x": 38.71691820009889, "y": -122.41937517163929, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "579c3e97-d1dc-4306-91e6-4cbbed29f882", "name": "p1rdt385lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "17902503-2dce-426d-8ec3-66c36f03f7c9"}}}}, {"uuid": "0575f243-1568-49fc-92d7-26cd6182fbca", "name": "", "x": 38.716892202729326, "y": -122.41933252291317, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "449992d6-a91b-40ea-9792-5166a5f2c849", "name": "p1rlv674", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0575f243-1568-49fc-92d7-26cd6182fbca"}}}}, {"uuid": "3a464616-ff46-4e66-bc71-73f7cb619077", "name": "", "x": 38.6691571170927, "y": -122.47438402684668, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "29a78735-964b-4381-bea0-01e5b1b79be9", "name": "p1rdt414lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3a464616-ff46-4e66-bc71-73f7cb619077"}}}}, {"uuid": "59455f0e-ff8f-4b31-b73e-898b6fbaf586", "name": "", "x": 38.669005790542414, "y": -122.47417070346637, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "93069f0f-fce7-47cd-b7b3-77e861f59573", "name": "p1rlv716", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59455f0e-ff8f-4b31-b73e-898b6fbaf586"}}}}, {"uuid": "4d4d97a1-ea59-48d6-b28a-5ea47726fe0d", "name": "", "x": 38.66935018999187, "y": -122.47460499537559, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1fdcbc55-681f-4fe5-8142-4945b25f6fef", "name": "p1rlv726", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d4d97a1-ea59-48d6-b28a-5ea47726fe0d"}}}}, {"uuid": "7488598b-5c4a-42eb-9cbf-5b2ea2c5d1db", "name": "", "x": 38.67353500851874, "y": -122.4699836494228, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "789d55de-619d-43cd-b056-ebe1be4c2dea", "name": "p1rdt415lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7488598b-5c4a-42eb-9cbf-5b2ea2c5d1db"}}}}, {"uuid": "8f512abc-7a0e-4beb-995e-afdea04ecb04", "name": "", "x": 38.67341206301482, "y": -122.47006900065233, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dd8fd159-f747-4ee4-a426-787f4eef4b42", "name": "p1rlv717", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8f512abc-7a0e-4beb-995e-afdea04ecb04"}}}}, {"uuid": "a5d9e4a8-f3b6-4cdb-9db1-c58f8b044a15", "name": "", "x": 38.673699700951325, "y": -122.46990593984998, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c3658479-7369-4bd9-be54-e7768c93a808", "name": "p1rlv724", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a5d9e4a8-f3b6-4cdb-9db1-c58f8b044a15"}}}}, {"uuid": "e0b96858-aa03-46db-b180-5ee0b94c7331", "name": "", "x": 38.67143528847217, "y": -122.47049470940273, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "473f5822-3412-4f3d-836e-f62314efa5b2", "name": "p1rdt416lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e0b96858-aa03-46db-b180-5ee0b94c7331"}}}}, {"uuid": "0afc18f9-d7cd-4f29-9b20-fee7da27741d", "name": "", "x": 38.67144963800081, "y": -122.4705455286412, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c4a1453b-98a3-4c2d-8ac2-c8b2ab1bfa4f", "name": "p1rlv718", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0afc18f9-d7cd-4f29-9b20-fee7da27741d"}}}}, {"uuid": "f4989904-872f-47d3-8701-93590820f835", "name": "", "x": 38.67352761620833, "y": -122.47084715807108, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "98bb09be-6506-49e8-8fd8-1a01d6861162", "name": "p1rdt417lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f4989904-872f-47d3-8701-93590820f835"}}}}, {"uuid": "e5c56170-5e6a-4e5e-93de-83a3668da549", "name": "", "x": 38.673541965589685, "y": -122.47089797885619, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d3153167-8b4c-40e4-abb7-3bdef86950c3", "name": "p1rlv719", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e5c56170-5e6a-4e5e-93de-83a3668da549"}}}}, {"uuid": "533f6e2a-609f-4f35-b833-e72a97fa7768", "name": "", "x": 38.669563658980074, "y": -122.47284200415966, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e189aaf-7650-49b4-83dd-94a29111aca2", "name": "p1rdt418lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "533f6e2a-609f-4f35-b833-e72a97fa7768"}}}}, {"uuid": "01cf012e-58c9-48bf-be58-f1427fe77a7e", "name": "", "x": 38.66958917702078, "y": -122.4727989145224, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cdbc11b7-5abf-4ff8-8d26-53faf4b1f3f5", "name": "p1rlv720", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "01cf012e-58c9-48bf-be58-f1427fe77a7e"}}}}, {"uuid": "203182a1-7f0b-4a5e-9a20-44d4dd2260c2", "name": "", "x": 38.67286897139167, "y": -122.46744763392057, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0d9603d6-5e5e-4cc0-aa86-1bdb80f7e1cf", "name": "p1rdt419lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "203182a1-7f0b-4a5e-9a20-44d4dd2260c2"}}}}, {"uuid": "43884182-507e-4cb3-964f-cbc372ccc34f", "name": "", "x": 38.67213944190893, "y": -122.46765283859665, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf12b67c-4df5-4dcb-a2e2-6ae2d0f82e65", "name": "p1rlv721", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "43884182-507e-4cb3-964f-cbc372ccc34f"}}}}, {"uuid": "398a58c5-8907-45e0-9604-09c0300e703e", "name": "", "x": 38.673435838033924, "y": -122.46736734084595, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7551be44-a4ca-4edb-b823-6495d163201e", "name": "p1rlv723", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "398a58c5-8907-45e0-9604-09c0300e703e"}}}}, {"uuid": "8c4e5f78-75c4-4283-98d4-ee2a1e884b43", "name": "", "x": 38.673174243579794, "y": -122.46731180115961, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b2bcbabc-a7fc-4230-8ec1-b6050af9cf58", "name": "p1rlv725", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8c4e5f78-75c4-4283-98d4-ee2a1e884b43"}}}}, {"uuid": "772b3248-d2cb-4f0b-ae16-539c1bc90128", "name": "", "x": 38.67078274236132, "y": -122.4676946740554, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "51673983-9230-421b-8501-bf71601b1b13", "name": "p1rdt420lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "772b3248-d2cb-4f0b-ae16-539c1bc90128"}}}}, {"uuid": "573c2087-0c8d-47da-9307-3efabbf971d7", "name": "", "x": 38.670756762481666, "y": -122.4676520348216, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4b7c6c65-e18c-4e79-b419-8894deb0d345", "name": "p1rlv722", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "573c2087-0c8d-47da-9307-3efabbf971d7"}}}}, {"uuid": "af8bd291-62f7-4b54-ba88-d62e96f0c893", "name": "", "x": 38.70121723278343, "y": -122.42203089954941, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "41f19802-32ca-4afc-8418-fe93e3ced1bb", "name": "p1rdt438lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "af8bd291-62f7-4b54-ba88-d62e96f0c893"}}}}, {"uuid": "b19a4f8f-5cf0-47ea-9609-4688e1df6de3", "name": "", "x": 38.70105000563393, "y": -122.4222662235864, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "80983704-a98f-46dc-a09f-700bd7df1a29", "name": "p1rlv749", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b19a4f8f-5cf0-47ea-9609-4688e1df6de3"}}}}, {"uuid": "4f2f25dd-3d70-420e-968d-3be4cdda8b52", "name": "", "x": 38.70143522055596, "y": -122.42180311856214, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b3c3b0fb-5a5d-439e-a350-b97ba0df41a0", "name": "p1rlv756", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4f2f25dd-3d70-420e-968d-3be4cdda8b52"}}}}, {"uuid": "4c670b17-732d-4dd3-98fc-a09595996303", "name": "", "x": 38.70124602203702, "y": -122.42077844448052, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bc7e7e51-f849-4bf4-b720-462daeb21932", "name": "p1rdt445lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c670b17-732d-4dd3-98fc-a09595996303"}}}}, {"uuid": "4ccd8de8-d3e4-446c-baf4-2b5f353790d1", "name": "", "x": 38.7012715204705, "y": -122.42073531744347, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e368704b-6c4b-4afb-a577-4b0d7a96dd65", "name": "p1rlv764", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ccd8de8-d3e4-446c-baf4-2b5f353790d1"}}}}, {"uuid": "1cc0b3d4-8021-4b32-8abb-e969a4fb62aa", "name": "", "x": 38.7015601074417, "y": -122.42258142494296, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0727e1f5-f2ca-4e19-9dc3-89e185002e52", "name": "p1rdt446lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1cc0b3d4-8021-4b32-8abb-e969a4fb62aa"}}}}, {"uuid": "c900b3f3-baf8-427c-8542-c5f2ffa1355a", "name": "", "x": 38.70157447780686, "y": -122.4226322555927, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "07381934-8e9b-4447-a330-e8af484331f1", "name": "p1rlv766", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c900b3f3-baf8-427c-8542-c5f2ffa1355a"}}}}, {"uuid": "4a885b64-5e1b-46ae-883a-62e3888a8c6a", "name": "", "x": 38.69708395346926, "y": -122.37425747756579, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "44f86829-17fc-4e83-b2a5-705454293161", "name": "p1rdt452lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4a885b64-5e1b-46ae-883a-62e3888a8c6a"}}}}, {"uuid": "918a6e1b-0380-4647-a2bd-aafaaf6b3a88", "name": "", "x": 38.69705554229972, "y": -122.37452973492258, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "180adab2-e49b-42e9-9aeb-42be0a7686c5", "name": "p1rlv786", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "918a6e1b-0380-4647-a2bd-aafaaf6b3a88"}}}}, {"uuid": "8dad0c31-e9b0-4799-b268-7c2874861bb7", "name": "", "x": 38.69721614595881, "y": -122.37422935064228, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b4fed6c4-6907-4601-9671-6f83d582dc45", "name": "p1rdm812", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8dad0c31-e9b0-4799-b268-7c2874861bb7"}}}}, {"uuid": "d3fc1810-0682-44c8-b0c8-c28ddb55de10", "name": "", "x": 38.69725422113334, "y": -122.3746085006707, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d00977fb-8d2a-44ca-aa9e-034894d6e280", "name": "p1rlv775", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d3fc1810-0682-44c8-b0c8-c28ddb55de10"}}}}, {"uuid": "75499f39-83de-43a8-a654-d945fb405baf", "name": "", "x": 38.6969100698522, "y": -122.37428951464027, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "090024f2-1724-4789-96da-174d1f5e65ec", "name": "p1rdm814", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "75499f39-83de-43a8-a654-d945fb405baf"}}}}, {"uuid": "a51d797c-e6f0-4b32-b7b9-c278c8b44c8c", "name": "", "x": 38.69694740684703, "y": -122.37453067672068, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4c5b1f75-47c0-45c3-9ef3-f97a445b242e", "name": "p1rlv776", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a51d797c-e6f0-4b32-b7b9-c278c8b44c8c"}}}}, {"uuid": "fa3c1915-fa2a-4d21-a0f6-6488b0414d01", "name": "", "x": 38.69672717493211, "y": -122.37432163006257, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d58e1471-844f-46ef-9d9a-43753b1dee25", "name": "p1rdt453lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa3c1915-fa2a-4d21-a0f6-6488b0414d01"}}}}, {"uuid": "fea9bebc-eef7-4fe5-b640-a25baff0a50c", "name": "", "x": 38.696649943652076, "y": -122.37428890620298, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ecd0e9ae-cbf4-4435-8a57-ad23e3e037b4", "name": "p1rdm815", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fea9bebc-eef7-4fe5-b640-a25baff0a50c"}}}}, {"uuid": "566e28aa-36fb-42ab-a68d-202b695174ed", "name": "", "x": 38.69663225777152, "y": -122.37457941885675, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "def7e507-cb62-42f5-8451-b8a742ef4eb2", "name": "p1rlv819", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "566e28aa-36fb-42ab-a68d-202b695174ed"}}}}, {"uuid": "7d2179fa-de53-465f-87d5-363053bbc7d5", "name": "", "x": 38.70111870876331, "y": -122.37432184237016, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d2e41779-98fa-453d-b4df-10a5dd61a4b5", "name": "p1rdm816", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7d2179fa-de53-465f-87d5-363053bbc7d5"}}}}, {"uuid": "3eef0e56-9c2d-4b51-ba64-e4b46a209297", "name": "", "x": 38.70112000065753, "y": -122.37456333253593, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6fb1fca8-7985-4356-a8de-7433fef7a454", "name": "p1rlv777", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3eef0e56-9c2d-4b51-ba64-e4b46a209297"}}}}, {"uuid": "253db7aa-5fce-4b55-9ec6-020f592f3b00", "name": "", "x": 38.70157181887224, "y": -122.3742643698461, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0b3e7941-9bdd-48f9-a4a5-a553da9bbb57", "name": "p1rdt454lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "253db7aa-5fce-4b55-9ec6-020f592f3b00"}}}}, {"uuid": "2d928d67-5f6a-413b-ae62-6f67424a1c6d", "name": "", "x": 38.70172394100054, "y": -122.37459257247573, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "87e4ddc3-ccc3-48af-bc35-d7d85f324ee7", "name": "p1rdm817", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2d928d67-5f6a-413b-ae62-6f67424a1c6d"}}}}, {"uuid": "b22926f4-6b7d-47e3-ae23-fadd82a8b5ac", "name": "", "x": 38.701795539168316, "y": -122.37449994744384, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e9ce2439-fcc7-4965-81ee-f875db83b003", "name": "p1rlv789", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b22926f4-6b7d-47e3-ae23-fadd82a8b5ac"}}}}, {"uuid": "66477536-d6bd-43e1-8c9e-745b5321f80e", "name": "", "x": 38.7013420827754, "y": -122.37396339276478, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bf188897-9db5-4ff4-8c5b-5932a8a794cf", "name": "p1rdm818", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "66477536-d6bd-43e1-8c9e-745b5321f80e"}}}}, {"uuid": "23378020-dbad-4f0d-b057-ffe4e0117567", "name": "", "x": 38.70145818262173, "y": -122.37376687845641, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3126c61-9602-45cf-8d57-27d26c14ca7e", "name": "p1rlv800", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "23378020-dbad-4f0d-b057-ffe4e0117567"}}}}, {"uuid": "846a1025-c69e-451f-9377-15537603c6e1", "name": "", "x": 38.70201519147799, "y": -122.37513054558815, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b757a90a-ade8-486f-90f1-e7c5e13708ba", "name": "p1rdm819", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "846a1025-c69e-451f-9377-15537603c6e1"}}}}, {"uuid": "fc9c2527-9baf-4404-96ae-ee464d18a789", "name": "", "x": 38.70182669191501, "y": -122.37527018819917, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "80d58665-ee8a-4f4e-a906-dc15aa3d8c6f", "name": "p1rlv778", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fc9c2527-9baf-4404-96ae-ee464d18a789"}}}}, {"uuid": "ce8a26f6-92ff-436e-bfa0-57e400e499d7", "name": "", "x": 38.7019178147915, "y": -122.37492836596363, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "53b40b3c-db5a-4fa0-bedb-f293c6eac473", "name": "p1rdt455lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ce8a26f6-92ff-436e-bfa0-57e400e499d7"}}}}, {"uuid": "87337660-1d35-46ef-9aa5-4733c6572e85", "name": "", "x": 38.70180590348404, "y": -122.37475286106623, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ea28f170-6bf0-47f7-a089-8375dff2ad4a", "name": "p1rdm820", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "87337660-1d35-46ef-9aa5-4733c6572e85"}}}}, {"uuid": "43ef4919-06d3-41a8-a235-9fbe88ea5687", "name": "", "x": 38.701671533532036, "y": -122.37490353316474, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d0089ee3-0cb4-434c-adc4-c91a8441ef0a", "name": "p1rlv787", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "43ef4919-06d3-41a8-a235-9fbe88ea5687"}}}}, {"uuid": "29077723-8ec8-453b-8c57-cdfce7b38831", "name": "", "x": 38.70149204551021, "y": -122.37504309725601, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "052949b1-9e85-4be7-993c-9e97efda3657", "name": "p1rlv811", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "29077723-8ec8-453b-8c57-cdfce7b38831"}}}}, {"uuid": "2c30f199-abfe-4d48-b1ca-b49cf7589e41", "name": "", "x": 38.69874038147765, "y": -122.37499407083057, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6abe982-a205-4607-bacf-08e9d7cb6f54", "name": "p1rdt456lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2c30f199-abfe-4d48-b1ca-b49cf7589e41"}}}}, {"uuid": "dd0efdae-a64f-41af-ba64-43b865c65806", "name": "", "x": 38.6988698234033, "y": -122.37507741848081, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33492e0f-c907-46c6-a529-503480b642bb", "name": "p1rlv837", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dd0efdae-a64f-41af-ba64-43b865c65806"}}}}, {"uuid": "0199de53-9365-434d-aa43-d2c1589ff2db", "name": "", "x": 38.69908332769086, "y": -122.37455807209501, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e3cae47a-4077-44e6-9761-fc30d85c3442", "name": "p1rdm822", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0199de53-9365-434d-aa43-d2c1589ff2db"}}}}, {"uuid": "e7862db2-6252-4c87-8f40-cc4b08525a6b", "name": "", "x": 38.699192938897575, "y": -122.3748331116339, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fbc761bf-480c-465c-9479-279832c50bc2", "name": "p1rlv779", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e7862db2-6252-4c87-8f40-cc4b08525a6b"}}}}, {"uuid": "fde861ab-384e-4d57-9c4b-8d29c452a1a4", "name": "", "x": 38.69872582718306, "y": -122.37511317064184, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "84ca6719-0bbc-440a-b0eb-23b8f32dcf47", "name": "p1rdm823", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fde861ab-384e-4d57-9c4b-8d29c452a1a4"}}}}, {"uuid": "a276efc9-12d7-4647-8126-ba4bf608023b", "name": "", "x": 38.69852447935862, "y": -122.37506494784137, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be4b6c4e-78d0-4c8e-907c-619f1e43c149", "name": "p1rlv831", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a276efc9-12d7-4647-8126-ba4bf608023b"}}}}, {"uuid": "dc7c9480-fff2-4481-9abb-71107106b522", "name": "", "x": 38.69449656825178, "y": -122.37575189359077, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "866745cc-62c9-429f-8389-fcc5a1710f17", "name": "p1rdt457lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dc7c9480-fff2-4481-9abb-71107106b522"}}}}, {"uuid": "fa6c14d6-12bd-4418-bb7c-5b75aabf228d", "name": "", "x": 38.69441132364952, "y": -122.37550717957821, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "20dcf67f-f04f-498a-830d-557ba7b4d867", "name": "p1rlv780", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa6c14d6-12bd-4418-bb7c-5b75aabf228d"}}}}, {"uuid": "845013de-0fa5-4507-86c0-0171eb46dab6", "name": "", "x": 38.694628638419935, "y": -122.3757007735009, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bf7e29df-0880-4c8c-aa5c-c43f24dd820e", "name": "p1rdm826", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "845013de-0fa5-4507-86c0-0171eb46dab6"}}}}, {"uuid": "4c292e42-91c1-425c-ab9d-78892c7e4836", "name": "", "x": 38.694609633506126, "y": -122.37551695428785, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2d1a96d5-f971-4116-9642-769ef5b97e7c", "name": "p1rlv783", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c292e42-91c1-425c-ab9d-78892c7e4836"}}}}, {"uuid": "be8d4ef3-4f9e-4921-94e3-a481ca49b2ff", "name": "", "x": 38.69466560426392, "y": -122.3758729377002, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eb137176-0642-4d87-ae40-1b7b0e1cb214", "name": "p1rlv795", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be8d4ef3-4f9e-4921-94e3-a481ca49b2ff"}}}}, {"uuid": "1a861ef0-a169-461f-abde-6f601141ce10", "name": "", "x": 38.694926011094644, "y": -122.37569818860291, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8fafab6a-7d1c-4b87-94b3-5bc4d09ff95d", "name": "p1rdm827", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1a861ef0-a169-461f-abde-6f601141ce10"}}}}, {"uuid": "01722373-7ba3-4bf0-a6df-8a4d2d2d63d4", "name": "", "x": 38.69489143888521, "y": -122.37597446682435, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3fe9bb3f-e3c1-4b59-b39f-f62271a55bdd", "name": "p1rlv791", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "01722373-7ba3-4bf0-a6df-8a4d2d2d63d4"}}}}, {"uuid": "9fc67f87-3522-4d69-a9a3-b9248ad5e601", "name": "", "x": 38.694187760198, "y": -122.37583109428404, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dc2d45e2-caa5-4f7d-976e-ccb045c30559", "name": "p1rdm829", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9fc67f87-3522-4d69-a9a3-b9248ad5e601"}}}}, {"uuid": "719b05d2-eba8-4118-9171-d1406b60336f", "name": "", "x": 38.694161769492204, "y": -122.3760268023747, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1ecc45b2-1fbe-4a31-995f-e2f8fffe61a7", "name": "p1rlv801", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "719b05d2-eba8-4118-9171-d1406b60336f"}}}}, {"uuid": "b6e99fb2-ec36-4ae6-9455-b941776f70f0", "name": "", "x": 38.69415358661105, "y": -122.37565138406234, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "11064c6f-3b7a-43b5-96ca-7ef96be3815e", "name": "p1rlv817", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b6e99fb2-ec36-4ae6-9455-b941776f70f0"}}}}, {"uuid": "f55d31ca-bc69-454e-8549-05d666f255d3", "name": "", "x": 38.695030276964474, "y": -122.37497283941411, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c668ab72-249e-4463-a3b4-863c7fe826c1", "name": "p1rdm831", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f55d31ca-bc69-454e-8549-05d666f255d3"}}}}, {"uuid": "ba483e47-e191-4d8f-aa43-0cdc306972f9", "name": "", "x": 38.69496811967224, "y": -122.37514586658888, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "98c5ba15-a339-478a-a79f-9298fab16a54", "name": "p1rlv781", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ba483e47-e191-4d8f-aa43-0cdc306972f9"}}}}, {"uuid": "b26f7ad4-878d-4d83-a117-65a1974f593c", "name": "", "x": 38.69490966180515, "y": -122.37485492226794, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "67e071ab-e3dc-4779-9e81-585547cd22ca", "name": "p1rdt458lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b26f7ad4-878d-4d83-a117-65a1974f593c"}}}}, {"uuid": "1c4ced69-d921-431e-a0ed-4f7bda33c6ce", "name": "", "x": 38.69482154193585, "y": -122.37469867853063, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "92f03cbf-2585-4e0e-ab0a-cda0b267b34d", "name": "p1rdm832", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1c4ced69-d921-431e-a0ed-4f7bda33c6ce"}}}}, {"uuid": "1da019c9-03b8-4947-aabc-fe8b39b50d8d", "name": "", "x": 38.69478038429, "y": -122.37489849683361, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c3bc013f-c78d-4a3c-b27f-826c3025de0e", "name": "p1rlv843", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1da019c9-03b8-4947-aabc-fe8b39b50d8d"}}}}, {"uuid": "379cb4d3-78c7-4221-af0f-e1a5b188a4bb", "name": "", "x": 38.701681041918285, "y": -122.37384145943425, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9eb57d99-ae80-43da-b0cb-b26bdd583e1a", "name": "p1rdt459lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "379cb4d3-78c7-4221-af0f-e1a5b188a4bb"}}}}, {"uuid": "e4637786-72a5-4382-96af-a9d4bb9b3ddd", "name": "", "x": 38.7019010899339, "y": -122.37401601985513, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "78a4f54a-017a-41b0-85c8-b3e408c21c08", "name": "p1rlv782", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e4637786-72a5-4382-96af-a9d4bb9b3ddd"}}}}, {"uuid": "77846b24-5292-42be-bdfc-2dd8cb5fe3f7", "name": "", "x": 38.70217626105635, "y": -122.37544717401559, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "028bc055-0ee6-4729-8cd2-15bd7153f975", "name": "p1rdt460lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "77846b24-5292-42be-bdfc-2dd8cb5fe3f7"}}}}, {"uuid": "b26c164b-bd1d-4e3b-b693-7687b88241a5", "name": "", "x": 38.70212578404628, "y": -122.37558959231082, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2823b5b9-bcc3-4b30-9874-89dc33ec80d2", "name": "p1rlv784", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b26c164b-bd1d-4e3b-b693-7687b88241a5"}}}}, {"uuid": "10c6883a-43b8-4c15-b651-d1ef7659c9b6", "name": "", "x": 38.702286881592116, "y": -122.37538118676348, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9b1c34f1-2613-46aa-9a9f-686ee518e559", "name": "p1rlv797", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10c6883a-43b8-4c15-b651-d1ef7659c9b6"}}}}, {"uuid": "b4b4ec33-db46-469e-a833-d5e498acc9ff", "name": "", "x": 38.702257020866284, "y": -122.37485243501904, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "790d0b88-fed2-4c90-bfdf-44d3c31d3d8d", "name": "p1rdm837", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b4b4ec33-db46-469e-a833-d5e498acc9ff"}}}}, {"uuid": "8295e92c-cbac-4f52-982a-bf37131d64d8", "name": "", "x": 38.70215746639765, "y": -122.37477280015747, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0d9f269a-e476-4b82-a258-479d812d008d", "name": "p1rlv806", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8295e92c-cbac-4f52-982a-bf37131d64d8"}}}}, {"uuid": "b98023ea-f8a2-432c-81a7-f05c1eec5f47", "name": "", "x": 38.702419502723, "y": -122.37467564114138, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e0e1d710-2ab1-43ca-a7c1-8f05a6c0b753", "name": "p1rdm835", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b98023ea-f8a2-432c-81a7-f05c1eec5f47"}}}}, {"uuid": "3396a052-4e10-4614-970a-e52b38290a46", "name": "", "x": 38.702500140978806, "y": -122.37481581739344, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "59662cef-c126-4188-ad86-844f6cabaf34", "name": "p1rlv796", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3396a052-4e10-4614-970a-e52b38290a46"}}}}, {"uuid": "e7917d2d-5f0a-4c8d-8ea2-3fd31c3312ae", "name": "", "x": 38.702324093645906, "y": -122.3755993680085, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "83fdcccd-6a26-4311-aad3-da67dac5af42", "name": "p1rdm838", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e7917d2d-5f0a-4c8d-8ea2-3fd31c3312ae"}}}}, {"uuid": "076990c7-d743-4fbb-89e1-5ebc4b093ce1", "name": "", "x": 38.70238649707223, "y": -122.37547232235222, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fb4a881f-684d-48e4-a6f0-5832f73d140a", "name": "p1rlv810", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "076990c7-d743-4fbb-89e1-5ebc4b093ce1"}}}}, {"uuid": "46076791-3910-4848-af07-6360ab1902cb", "name": "", "x": 38.70245104977729, "y": -122.37574776762911, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "344c24ef-9d54-4c1a-9aa4-852a76ddbec7", "name": "p1rdm839", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "46076791-3910-4848-af07-6360ab1902cb"}}}}, {"uuid": "364fe691-43cc-4586-8fbb-f3eed45bd625", "name": "", "x": 38.702223773417444, "y": -122.37590677054554, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d7ce197c-cee4-40df-b1d7-be13f1be8bb1", "name": "p1rlv822", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "364fe691-43cc-4586-8fbb-f3eed45bd625"}}}}, {"uuid": "69fe6bcf-63e7-4326-8de4-0eb763d1cef8", "name": "", "x": 38.70257800572197, "y": -122.37589616777406, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f0649432-ddb6-4648-8efe-27ee1fd959e4", "name": "p1rdm840", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "69fe6bcf-63e7-4326-8de4-0eb763d1cef8"}}}}, {"uuid": "e3ed841d-238a-473c-a6d8-4520609914f3", "name": "", "x": 38.70249776336369, "y": -122.37605786929961, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48e97be9-1f80-457f-a56e-79f54458c620", "name": "p1rlv839", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e3ed841d-238a-473c-a6d8-4520609914f3"}}}}, {"uuid": "fb47db4c-2eb8-46db-9d85-36ca6f7eac85", "name": "", "x": 38.69757588310151, "y": -122.37577864853107, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "505b390e-ffd3-482a-8ae9-b8d6bd8be94f", "name": "p1rdm841", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fb47db4c-2eb8-46db-9d85-36ca6f7eac85"}}}}, {"uuid": "7a77042f-fabf-48ca-b7bc-e10792c76c69", "name": "", "x": 38.69764123251456, "y": -122.37620356241798, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fa98d6c6-7086-4033-a9af-c0a33e802942", "name": "p1rlv785", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7a77042f-fabf-48ca-b7bc-e10792c76c69"}}}}, {"uuid": "f5f55bde-5e43-4018-86ad-8b885d9136a3", "name": "", "x": 38.697416472212836, "y": -122.37577251090494, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fd9a4931-435b-4b48-907c-024c0b8a4816", "name": "p1rdt461lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5f55bde-5e43-4018-86ad-8b885d9136a3"}}}}, {"uuid": "ebe1a657-73a9-459f-b0e0-fec2ca16456a", "name": "", "x": 38.69704403287731, "y": -122.37574877318404, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "172dd9d0-eab4-4481-9edd-f868e6ed87d9", "name": "p1rdm842", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ebe1a657-73a9-459f-b0e0-fec2ca16456a"}}}}, {"uuid": "3ccc8255-f565-4d1d-a03a-3ea1fc03d740", "name": "", "x": 38.69698334699525, "y": -122.37619777752667, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0e8c4bc9-0688-43e6-93a8-9664c9b618b7", "name": "p1rlv793", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3ccc8255-f565-4d1d-a03a-3ea1fc03d740"}}}}, {"uuid": "c0565ae7-3fec-4631-b6f3-a84c739859a2", "name": "", "x": 38.702201293623176, "y": -122.37338841314656, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d96f458-607c-4820-90b1-6fb2625ace7f", "name": "p1rdt462lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c0565ae7-3fec-4631-b6f3-a84c739859a2"}}}}, {"uuid": "117ffc96-232e-4015-aac7-6296e312ddff", "name": "", "x": 38.70221229583861, "y": -122.37323129022502, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bf42fa7f-370e-400e-8f6d-76eb8c70ecb9", "name": "p1rlv790", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "117ffc96-232e-4015-aac7-6296e312ddff"}}}}, {"uuid": "66ee1141-41be-44d4-b986-8ebb97d5a851", "name": "", "x": 38.702384188075854, "y": -122.3733562927121, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3ac64728-e64c-4241-8a3f-b884f11c6393", "name": "p1rdm843", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "66ee1141-41be-44d4-b986-8ebb97d5a851"}}}}, {"uuid": "860e4eab-613f-40e5-be26-b497bf4248c4", "name": "", "x": 38.70231135824942, "y": -122.37321892523424, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c9f470d9-6ead-4413-ad8a-7ccc69ae9237", "name": "p1rlv788", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "860e4eab-613f-40e5-be26-b497bf4248c4"}}}}, {"uuid": "dd8c6bac-9564-42dc-9c64-f3f6da327a3c", "name": "", "x": 38.7025463910665, "y": -122.37335487708582, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2086cded-e13c-4683-824e-9e15f99e12e8", "name": "p1rdm846", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dd8c6bac-9564-42dc-9c64-f3f6da327a3c"}}}}, {"uuid": "4c0f531e-29cb-4717-b893-ab2bbcda29c3", "name": "", "x": 38.70252953923245, "y": -122.37357352972886, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6e2a8871-7bc4-497f-9954-38db92cb3eba", "name": "p1rlv864", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c0f531e-29cb-4717-b893-ab2bbcda29c3"}}}}, {"uuid": "c59df0b4-eab3-43e2-9baa-fb2da89819cf", "name": "", "x": 38.702105331447335, "y": -122.37345072820672, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b4620a0-c781-422e-8cc7-3ceed9a0c8dc", "name": "p1rdm845", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c59df0b4-eab3-43e2-9baa-fb2da89819cf"}}}}, {"uuid": "f1970de7-55c0-4d65-a1ad-1d38a4180337", "name": "", "x": 38.70188944897217, "y": -122.37299658085036, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "024961c3-25f4-4a15-a52a-7f88dc652766", "name": "p1rlv840", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f1970de7-55c0-4d65-a1ad-1d38a4180337"}}}}, {"uuid": "c6c1d19e-c4b9-419a-a813-bc297120bd26", "name": "", "x": 38.702162992217495, "y": -122.3735922043492, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "abdfa5db-c398-4638-805d-6d55597e1921", "name": "p1rlv865", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c6c1d19e-c4b9-419a-a813-bc297120bd26"}}}}, {"uuid": "b294bc07-25bb-471e-adef-295df19ea6ae", "name": "", "x": 38.702251051988306, "y": -122.37373696284877, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1a7cca48-fd4b-4630-a479-55f2b6ada03b", "name": "p1rlv867", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b294bc07-25bb-471e-adef-295df19ea6ae"}}}}, {"uuid": "4ee440dd-1144-418b-b9e5-686ac95fe047", "name": "", "x": 38.70003035932669, "y": -122.37586478778037, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f660c35e-85f8-4f0e-b03b-806006c76c67", "name": "p1rdt463lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ee440dd-1144-418b-b9e5-686ac95fe047"}}}}, {"uuid": "6c8c6605-54a0-4f74-a558-cea62a6e6755", "name": "", "x": 38.7000284875326, "y": -122.37604482598387, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f806232e-0a52-46d5-80f7-7ea3a914137a", "name": "p1rlv792", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c8c6605-54a0-4f74-a558-cea62a6e6755"}}}}, {"uuid": "a1a9621f-11fc-426f-87dd-3d67019f0b3b", "name": "", "x": 38.699938225668625, "y": -122.37578973798107, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c397a5a5-21bc-4f4d-9f24-7af1219b70e7", "name": "p1rdm850", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a1a9621f-11fc-426f-87dd-3d67019f0b3b"}}}}, {"uuid": "28e708f2-3c1d-404d-8dcb-ecb29b51303c", "name": "", "x": 38.69980443234621, "y": -122.37627677000896, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bada1117-5605-4aec-9314-8013ed243e3c", "name": "p1rlv860", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "28e708f2-3c1d-404d-8dcb-ecb29b51303c"}}}}, {"uuid": "21cd6750-0958-4f0b-9fd8-b9f9372c0348", "name": "", "x": 38.69546877867281, "y": -122.373869079739, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "749e07aa-74ce-40f2-a352-9c55f9914377", "name": "p1rdt464lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "21cd6750-0958-4f0b-9fd8-b9f9372c0348"}}}}, {"uuid": "65f83ebc-aea0-429a-a6b4-dc69a6e34403", "name": "", "x": 38.6953493322175, "y": -122.37396963727394, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4eecc456-41af-4242-ab30-d8ca45d55a2c", "name": "p1rlv794", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65f83ebc-aea0-429a-a6b4-dc69a6e34403"}}}}, {"uuid": "efde92d7-4f87-4aa8-833a-398f86a5bcd0", "name": "", "x": 38.69564655774635, "y": -122.37393116894758, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "17b42dae-f856-4945-ba7a-9d3f47e049fe", "name": "p1rdm852", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "efde92d7-4f87-4aa8-833a-398f86a5bcd0"}}}}, {"uuid": "ede6db0e-440b-4e2d-8435-9539c4f9fe4c", "name": "", "x": 38.69550381660122, "y": -122.37420977320264, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d209dff6-7a24-41ef-947a-8c6f79c2d65c", "name": "p1rlv825", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ede6db0e-440b-4e2d-8435-9539c4f9fe4c"}}}}, {"uuid": "6c196105-5de5-4ebf-8534-5b9673501c2d", "name": "", "x": 38.69529421784077, "y": -122.37377463240384, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "08c93f8a-9600-4ffd-8e18-576d433ce777", "name": "p1rdm853", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c196105-5de5-4ebf-8534-5b9673501c2d"}}}}, {"uuid": "00f12ce4-6279-4f7f-b351-ef6b4d9d1895", "name": "", "x": 38.6954016143038, "y": -122.37363570614771, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8e3a1bd0-69fe-42bb-993d-2094ecc658ce", "name": "p1rlv829", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "00f12ce4-6279-4f7f-b351-ef6b4d9d1895"}}}}, {"uuid": "a12d289b-3eb4-436f-9fcb-4e06e31acedf", "name": "", "x": 38.6980078724581, "y": -122.37567139741331, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d5ad091a-3b6a-4069-a642-104c28a94dc4", "name": "p1rdm855", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a12d289b-3eb4-436f-9fcb-4e06e31acedf"}}}}, {"uuid": "e1b7c1d6-d5c9-416e-b644-68ca8ac89c67", "name": "", "x": 38.69804305798535, "y": -122.3755100974583, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e0f8ee8-795f-4bea-bf7a-e2c477eefb89", "name": "p1rlv809", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e1b7c1d6-d5c9-416e-b644-68ca8ac89c67"}}}}, {"uuid": "5f783c36-4d6c-46a7-a596-a1775597daf0", "name": "", "x": 38.69840981645937, "y": -122.37572585292882, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "433b0872-49c4-452c-941c-8083a72840ce", "name": "p1rdt465lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5f783c36-4d6c-46a7-a596-a1775597daf0"}}}}, {"uuid": "e28eaec9-f284-4eaf-8033-7359f6a39638", "name": "", "x": 38.69867415513827, "y": -122.37556210766509, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eaf112db-b9dc-4d90-b030-3e26188aaf2b", "name": "p1rdm856", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e28eaec9-f284-4eaf-8033-7359f6a39638"}}}}, {"uuid": "6f275d6c-b659-4a8f-9701-15a2f8ced9bc", "name": "", "x": 38.69855682418657, "y": -122.37552862894972, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d5e2c3a2-32c0-4bb9-9802-265cec784974", "name": "p1rlv862", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6f275d6c-b659-4a8f-9701-15a2f8ced9bc"}}}}, {"uuid": "13e20615-a6e4-4635-9781-ad96b92e29cd", "name": "", "x": 38.6988553632223, "y": -122.37574452723823, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eb73d9f2-aefb-430c-babd-ac02422eb212", "name": "p1rdm854", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "13e20615-a6e4-4635-9781-ad96b92e29cd"}}}}, {"uuid": "b48c379e-4147-4789-8a0b-4f78bd953f0b", "name": "", "x": 38.69885849252648, "y": -122.3763309850566, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c30005d7-7e42-4a08-8935-0c7227fba4a6", "name": "p1rlv798", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b48c379e-4147-4789-8a0b-4f78bd953f0b"}}}}, {"uuid": "b9e5cf5a-e99c-413d-b8a9-d68c8495cc17", "name": "", "x": 38.697834262777405, "y": -122.37522442460597, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c274aa99-a566-4915-83af-7115bec586b1", "name": "p1rdm857", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b9e5cf5a-e99c-413d-b8a9-d68c8495cc17"}}}}, {"uuid": "d06026e0-9130-4360-96b9-adbed16f39bd", "name": "", "x": 38.69763601444608, "y": -122.37522614936233, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6f706d9d-0cb1-453b-9ca5-377f7d766099", "name": "p1rlv799", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d06026e0-9130-4360-96b9-adbed16f39bd"}}}}, {"uuid": "d3d04da5-e3f9-4ba5-96af-05e7b20a1b7b", "name": "", "x": 38.69792563161655, "y": -122.37492861747332, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f422478c-0d77-48c8-87fb-e883d945f8a6", "name": "p1rdt466lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d3d04da5-e3f9-4ba5-96af-05e7b20a1b7b"}}}}, {"uuid": "6a7949b0-112b-4610-a8e8-2178e83b8af6", "name": "", "x": 38.69756758613625, "y": -122.37422628827595, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "caa7d639-522c-4fd6-8b74-73a337bd67d2", "name": "p1rdm858", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a7949b0-112b-4610-a8e8-2178e83b8af6"}}}}, {"uuid": "be08b287-4bce-4f87-b15e-4e011958954e", "name": "", "x": 38.69752942558697, "y": -122.37436063848634, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7a134556-828b-4e0c-8773-2f207802e33a", "name": "p1rlv815", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be08b287-4bce-4f87-b15e-4e011958954e"}}}}, {"uuid": "11ac6b38-60a5-49b9-8a0a-540db3fefb3c", "name": "", "x": 38.694252540223, "y": -122.37330828127818, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "23ed76af-dcb2-4333-ae4c-d7439a37cf87", "name": "p1rdt467lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "11ac6b38-60a5-49b9-8a0a-540db3fefb3c"}}}}, {"uuid": "d1963ecf-1914-499a-8472-b5247aebbf28", "name": "", "x": 38.69427815650523, "y": -122.37304358141793, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b2436086-d5c4-4b70-a402-e7d1b6f5b77e", "name": "p1rlv802", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1963ecf-1914-499a-8472-b5247aebbf28"}}}}, {"uuid": "3be967c7-0670-4f96-b81c-c29550a7414c", "name": "", "x": 38.695512481684965, "y": -122.37583108066667, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3a4bf0e0-92f0-4cd9-afc5-65d9ed242271", "name": "p1rdm861", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3be967c7-0670-4f96-b81c-c29550a7414c"}}}}, {"uuid": "efeb21c5-4624-459c-9e98-5cc05610708d", "name": "", "x": 38.69558659678035, "y": -122.3762099095591, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "81802469-7320-47e9-b826-fbb33bd371ab", "name": "p1rlv823", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "efeb21c5-4624-459c-9e98-5cc05610708d"}}}}, {"uuid": "033a2a11-14fb-4987-9143-4c5ea81d6861", "name": "", "x": 38.695386323591904, "y": -122.37583217708425, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3bfca289-c04c-45d9-8104-40089fc1737e", "name": "p1rdm860", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "033a2a11-14fb-4987-9143-4c5ea81d6861"}}}}, {"uuid": "a8f165ab-776e-40e3-8147-22b245234707", "name": "", "x": 38.6953513829787, "y": -122.3760394653489, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "018c978c-5673-4090-9792-b75ee161f6d2", "name": "p1rlv803", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8f165ab-776e-40e3-8147-22b245234707"}}}}, {"uuid": "a29fd963-e063-4256-9052-473ca445a911", "name": "", "x": 38.69564629017529, "y": -122.3756964667581, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b368fb8f-7f4d-4558-b6b2-2e1db4087727", "name": "p1rdt468lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a29fd963-e063-4256-9052-473ca445a911"}}}}, {"uuid": "f35e8328-37b1-44a2-a763-afa113575634", "name": "", "x": 38.696223821296954, "y": -122.37572140485321, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1daf402d-faec-4230-b4ab-1efa6283ac0f", "name": "p1rdm862", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f35e8328-37b1-44a2-a763-afa113575634"}}}}, {"uuid": "0c90b1a8-53a5-4b65-b599-aa1c94439206", "name": "", "x": 38.696252021310734, "y": -122.37593964620868, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2eb57fc4-636d-4923-9f4a-d308b062599f", "name": "p1rlv833", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0c90b1a8-53a5-4b65-b599-aa1c94439206"}}}}, {"uuid": "4c5c36ba-98c8-4540-bd20-b43167f47a63", "name": "", "x": 38.69464965312743, "y": -122.37341980651155, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d12ab15f-746d-462b-b395-e2b330ba1226", "name": "p1rdt469lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c5c36ba-98c8-4540-bd20-b43167f47a63"}}}}, {"uuid": "a5345d32-563a-4acd-b251-ba5e631ee422", "name": "", "x": 38.6946876894052, "y": -122.37326246422553, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0475b34e-14ab-48e4-9df7-7444de1cde7d", "name": "p1rlv805", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a5345d32-563a-4acd-b251-ba5e631ee422"}}}}, {"uuid": "087c125b-3c1d-4629-a9c6-0573dbf2e0c5", "name": "", "x": 38.70251978737086, "y": -122.37458961698891, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "15ab2647-a801-4cb5-a1f7-528118ff5dea", "name": "p1rdt470lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "087c125b-3c1d-4629-a9c6-0573dbf2e0c5"}}}}, {"uuid": "689170c1-88d4-43af-91c5-010c0ce51404", "name": "", "x": 38.70270494012969, "y": -122.37435402129528, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ab33ce2f-3131-4cfb-8df2-329fb4aa76b7", "name": "p1rlv858", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "689170c1-88d4-43af-91c5-010c0ce51404"}}}}, {"uuid": "f578b711-1e16-41bc-aea1-727982d2a44c", "name": "", "x": 38.70236818204675, "y": -122.3747179490724, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d861761c-3fe7-437d-917d-8beb24318a42", "name": "p1rdm864", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f578b711-1e16-41bc-aea1-727982d2a44c"}}}}, {"uuid": "186932a4-38ef-4136-bf3f-59f1cf536dfd", "name": "", "x": 38.702215723425525, "y": -122.37440030860232, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aa259be8-8a61-461a-9e58-d4aaf1ce82db", "name": "p1rlv807", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "186932a4-38ef-4136-bf3f-59f1cf536dfd"}}}}, {"uuid": "0a7684b2-4e2a-4be3-aaf0-80e9592fb790", "name": "", "x": 38.701111976317726, "y": -122.37359342043746, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "40d98c0b-4c66-4581-9553-f5f57c4b27b9", "name": "p1rdt471lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a7684b2-4e2a-4be3-aaf0-80e9592fb790"}}}}, {"uuid": "85ea6224-1682-4dce-aec8-40cb358842c6", "name": "", "x": 38.7012040803456, "y": -122.37343559224011, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "06746d4d-3db8-45b1-888e-d3d9e405ccaf", "name": "p1rlv826", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "85ea6224-1682-4dce-aec8-40cb358842c6"}}}}, {"uuid": "50db1ac5-4754-41e4-9d37-bda897dc343b", "name": "", "x": 38.701232962213865, "y": -122.37378034278039, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "467753c6-5c1f-4a9d-8a7d-21419b25565f", "name": "p1rdm866", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "50db1ac5-4754-41e4-9d37-bda897dc343b"}}}}, {"uuid": "dedcff52-3cd3-467f-9c45-71a2c3e1ba7b", "name": "", "x": 38.70131313984175, "y": -122.37360714205926, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9dcb86a4-e6d7-48b4-b5c2-904635de271b", "name": "p1rlv808", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dedcff52-3cd3-467f-9c45-71a2c3e1ba7b"}}}}, {"uuid": "38d6ab03-3e7f-4fd9-883e-cfa2538e6a9f", "name": "", "x": 38.69441071978218, "y": -122.3742383194926, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f026a1d3-23b0-4454-a09b-e1c08cc06392", "name": "p1rdt472lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "38d6ab03-3e7f-4fd9-883e-cfa2538e6a9f"}}}}, {"uuid": "13e8ba29-89b7-4d05-a57a-3f34b24cc43e", "name": "", "x": 38.69453022804182, "y": -122.37414926221291, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6b4834dc-6bdf-4102-bc13-589392b2e75a", "name": "p1rlv866", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "13e8ba29-89b7-4d05-a57a-3f34b24cc43e"}}}}, {"uuid": "f2a7e3eb-ae43-49d8-b76c-8971895da950", "name": "", "x": 38.69435012529591, "y": -122.37417382958121, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f0ca3ea5-ad01-4e52-883a-c07805f613dd", "name": "p1rdm868", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f2a7e3eb-ae43-49d8-b76c-8971895da950"}}}}, {"uuid": "2576f1fb-b6fb-4af7-8366-e83fc7c59d2f", "name": "", "x": 38.69438573967901, "y": -122.37409302632886, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "26fea867-af5f-4213-b9c3-487975d1285e", "name": "p1rlv812", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2576f1fb-b6fb-4af7-8366-e83fc7c59d2f"}}}}, {"uuid": "7cbb35e7-df97-4165-aed4-3095857f8894", "name": "", "x": 38.69659862303915, "y": -122.37433121095306, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0aa0c31f-baa3-4db8-87d9-0a4ab9a83a8a", "name": "p1rdm870", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7cbb35e7-df97-4165-aed4-3095857f8894"}}}}, {"uuid": "c2ef7e3c-d290-41bb-8503-30c839028bfd", "name": "", "x": 38.69661091258349, "y": -122.37395864008647, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "10d44b60-55c0-4d78-abbb-52c8cd67134b", "name": "p1rlv813", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c2ef7e3c-d290-41bb-8503-30c839028bfd"}}}}, {"uuid": "a0e9fbf2-0b6f-4d7f-8873-daa40e499cae", "name": "", "x": 38.696471493549275, "y": -122.3743203106189, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1f435ec5-8c03-45ba-925b-83bad9501047", "name": "p1rdt473lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a0e9fbf2-0b6f-4d7f-8873-daa40e499cae"}}}}, {"uuid": "a099f1a8-ca54-48a4-85f5-70fbea769a79", "name": "", "x": 38.69629742532447, "y": -122.37431785096992, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "67c560cc-d815-41d4-8087-b66beaacb404", "name": "p1rdm871", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a099f1a8-ca54-48a4-85f5-70fbea769a79"}}}}, {"uuid": "d682dfc2-070f-47a5-a193-156d255f04d9", "name": "", "x": 38.6963229822717, "y": -122.37404164512883, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dd8c54fd-14d4-46fa-8bef-59c1097d5026", "name": "p1rlv818", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d682dfc2-070f-47a5-a193-156d255f04d9"}}}}, {"uuid": "d100526f-6d59-48eb-8c30-a2e68b037935", "name": "", "x": 38.695202937157, "y": -122.37577229914999, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "839858f4-3b18-40c3-86f3-e27225e6aba4", "name": "p1rdt474lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d100526f-6d59-48eb-8c30-a2e68b037935"}}}}, {"uuid": "cc9ae46b-eb99-4a30-b30b-6b6e84f4c59e", "name": "", "x": 38.695250110678316, "y": -122.37563787569754, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b8065f3-8286-4f99-aa56-b9b631a2f838", "name": "p1rlv814", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc9ae46b-eb99-4a30-b30b-6b6e84f4c59e"}}}}, {"uuid": "39fb4e3a-9f26-4cfc-9385-c44381ad05b3", "name": "", "x": 38.69519831370313, "y": -122.37606379343438, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1c89db91-40fe-4de6-973e-5d8c23e35080", "name": "p1rlv827", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "39fb4e3a-9f26-4cfc-9385-c44381ad05b3"}}}}, {"uuid": "9c3d2d3a-8524-4e4a-a0b2-c952bd788674", "name": "", "x": 38.69669246979562, "y": -122.37572883039154, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0ec705b7-fdaa-4eca-96eb-5dabb8256c78", "name": "p1rdm874", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9c3d2d3a-8524-4e4a-a0b2-c952bd788674"}}}}, {"uuid": "9eb67d1a-af44-45e3-8bdb-c4ad6a6e4c48", "name": "", "x": 38.696700867165035, "y": -122.37561376379026, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0d6de7c2-fd2c-4071-8e90-1513f521cf87", "name": "p1rlv816", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9eb67d1a-af44-45e3-8bdb-c4ad6a6e4c48"}}}}, {"uuid": "f6f806f4-f6c8-4acc-b5d4-dc9e58c721ea", "name": "", "x": 38.69688462197356, "y": -122.37574263565365, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1be3e20a-3890-4e9c-b568-ca99421e751c", "name": "p1rdt475lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f6f806f4-f6c8-4acc-b5d4-dc9e58c721ea"}}}}, {"uuid": "41f402a8-5a0d-43bb-92ca-31ba1dcfa4df", "name": "", "x": 38.69722432005433, "y": -122.37575870547994, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c17541ac-d30f-4f0a-9660-f9b9f7012b3a", "name": "p1rdm875", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "41f402a8-5a0d-43bb-92ca-31ba1dcfa4df"}}}}, {"uuid": "3d63d01d-b418-490e-98e2-bd17b4c6be29", "name": "", "x": 38.697222293760795, "y": -122.37537924143979, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d437c83c-cbd1-41bf-b455-21123e82d59f", "name": "p1rlv834", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3d63d01d-b418-490e-98e2-bd17b4c6be29"}}}}, {"uuid": "67a0c060-3859-4b1c-be3d-76b775d3991e", "name": "", "x": 38.70013424053621, "y": -122.37444144316905, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2ffde8c6-9dba-4f13-bda5-a0edf17c736d", "name": "p1rdt476lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "67a0c060-3859-4b1c-be3d-76b775d3991e"}}}}, {"uuid": "ced3b102-df6d-43e6-b894-4e4cf7a0fc03", "name": "", "x": 38.700172278057, "y": -122.37428408934844, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "12556ab7-c50a-4624-9d84-b85585822245", "name": "p1rlv836", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ced3b102-df6d-43e6-b894-4e4cf7a0fc03"}}}}, {"uuid": "6a4ba861-04bc-46c0-9877-3f78ef3e6dcc", "name": "", "x": 38.700326331213084, "y": -122.37444374611572, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f83e2ade-1911-4124-9fbe-6f482d68eba9", "name": "p1rdm878", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a4ba861-04bc-46c0-9877-3f78ef3e6dcc"}}}}, {"uuid": "650858b8-9d22-4882-8e53-a5090bc3e20b", "name": "", "x": 38.700363298980754, "y": -122.37461592326322, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e8f304a4-6e39-4288-9b9b-e41bb37c6019", "name": "p1rlv842", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "650858b8-9d22-4882-8e53-a5090bc3e20b"}}}}, {"uuid": "69c25aa2-cce5-47a1-bd11-f511d4e7ef98", "name": "", "x": 38.69999291375323, "y": -122.3744466507155, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "260b560c-e6d6-4069-b67f-067c468a7768", "name": "p1rdm879", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "69c25aa2-cce5-47a1-bd11-f511d4e7ef98"}}}}, {"uuid": "0b280d8d-3c4c-40e9-9412-11a35d68ccb0", "name": "", "x": 38.699967724899935, "y": -122.37479186664717, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "009758e3-b4ae-427a-9c30-f2a8bb2953d1", "name": "p1rlv868", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0b280d8d-3c4c-40e9-9412-11a35d68ccb0"}}}}, {"uuid": "74720137-2719-4bda-bd40-f1e0e83c7549", "name": "", "x": 38.69983071065769, "y": -122.37444806374667, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e5331a4f-ab91-4fea-a301-11b7afb6c8ca", "name": "p1rdm876", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "74720137-2719-4bda-bd40-f1e0e83c7549"}}}}, {"uuid": "4acdc884-dafb-47f0-9aef-0750c98c89a2", "name": "", "x": 38.69982305246386, "y": -122.37470112738258, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "41e1e576-4cc9-4fea-9d87-d436f000a675", "name": "p1rlv820", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4acdc884-dafb-47f0-9aef-0750c98c89a2"}}}}, {"uuid": "be4b1091-7833-463e-9423-9a59a5df48db", "name": "", "x": 38.70067167519556, "y": -122.37445621396152, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7c94703b-303a-4713-95c0-b2933fe0e70b", "name": "p1rdt477lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be4b1091-7833-463e-9423-9a59a5df48db"}}}}, {"uuid": "45c28223-7f02-491e-a73b-3b9744100bd2", "name": "", "x": 38.700632038038435, "y": -122.37431458299233, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5578d8b4-7c1e-444f-8d27-8c9bf733f420", "name": "p1rlv821", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "45c28223-7f02-491e-a73b-3b9744100bd2"}}}}, {"uuid": "ffdcebf1-e780-4f8b-91bb-fc038927b448", "name": "", "x": 38.700597838321514, "y": -122.37465988051781, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "08c3f5ef-c2d5-4ce2-8fc7-b665d8cbbab6", "name": "p1rlv828", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ffdcebf1-e780-4f8b-91bb-fc038927b448"}}}}, {"uuid": "f5cc1ded-e0f7-495c-ae2c-fbbe9b223fcf", "name": "", "x": 38.69822971347937, "y": -122.37575041780734, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c93c776d-68b8-4e4e-8e5e-d5e34003473c", "name": "p1rdt478lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5cc1ded-e0f7-495c-ae2c-fbbe9b223fcf"}}}}, {"uuid": "3f010d14-4b1e-42be-b585-e0ced44c54ea", "name": "", "x": 38.69822653688614, "y": -122.37611798096295, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "20ce76b6-9305-4525-b77e-b7300edc2c81", "name": "p1rlv824", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3f010d14-4b1e-42be-b585-e0ced44c54ea"}}}}, {"uuid": "ee288a4b-1410-407e-bb84-038feb7a9f5a", "name": "", "x": 38.70127438508099, "y": -122.37425546173934, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8037b713-d948-43c9-8370-fb8fcf6dec15", "name": "p1rdt479lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ee288a4b-1410-407e-bb84-038feb7a9f5a"}}}}, {"uuid": "eb04d832-c5da-4476-b767-3f3132f84fd6", "name": "", "x": 38.701326152810886, "y": -122.3743545350747, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "10373c0d-6a3c-4160-a174-22de447d4c38", "name": "p1rlv832", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eb04d832-c5da-4476-b767-3f3132f84fd6"}}}}, {"uuid": "8a561549-d427-4eb0-aff8-0cac6f22dd4a", "name": "", "x": 38.69561552385404, "y": -122.3739765254889, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "423402f9-4160-481b-9951-a955f8314075", "name": "p1rdt480lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8a561549-d427-4eb0-aff8-0cac6f22dd4a"}}}}, {"uuid": "58cd95d9-c795-4a7d-bf6a-852a7830e1c7", "name": "", "x": 38.69578897651805, "y": -122.37360932935272, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3bc35476-5839-4095-bea5-36e32450b890", "name": "p1rlv835", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "58cd95d9-c795-4a7d-bf6a-852a7830e1c7"}}}}, {"uuid": "1e7206f1-15d5-4231-864e-462f41dde77f", "name": "", "x": 38.69655114284914, "y": -122.37573403506332, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1761b021-00e0-4880-9f05-62cf67aef0e6", "name": "p1rdt481lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1e7206f1-15d5-4231-864e-462f41dde77f"}}}}, {"uuid": "cf2f06ed-eba1-449a-9286-5b45dc3920ec", "name": "", "x": 38.69650464427591, "y": -122.37599494765684, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4eb6c1b4-f09a-44a5-a13f-64051183736d", "name": "p1rlv841", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cf2f06ed-eba1-449a-9286-5b45dc3920ec"}}}}, {"uuid": "ea3ccfaa-4380-4f10-a9e3-de4b5e7d3502", "name": "", "x": 38.70357693514638, "y": -122.37510942987323, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c445ea76-5167-4d55-b0c5-cc53dadc5b5e", "name": "p1rdt482lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea3ccfaa-4380-4f10-a9e3-de4b5e7d3502"}}}}, {"uuid": "d417a786-cd49-46fd-ae63-d886ea429ad5", "name": "", "x": 38.70335811800441, "y": -122.37516485990416, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "26294827-db76-40b6-b652-1e41efdf15dc", "name": "p1rlv844", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d417a786-cd49-46fd-ae63-d886ea429ad5"}}}}, {"uuid": "0dab527d-342b-4f34-87fb-05ef650c3c36", "name": "", "x": 38.70345472163367, "y": -122.37469250108072, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3929a951-8b8b-42e9-a839-40c29e680108", "name": "p1rdm887", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0dab527d-342b-4f34-87fb-05ef650c3c36"}}}}, {"uuid": "d45f0194-8734-4ee3-9e7f-98f34d433fb6", "name": "", "x": 38.703250684927625, "y": -122.37476725706298, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "145d3757-ca09-45ca-9199-465b6b43fbb7", "name": "p1rlv846", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d45f0194-8734-4ee3-9e7f-98f34d433fb6"}}}}, {"uuid": "66e67166-f14a-476d-8648-058991b142e5", "name": "", "x": 38.70365739465258, "y": -122.37551877012066, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0318cdac-5c7b-4711-a0d7-9c7e104c8281", "name": "p1rdm888", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "66e67166-f14a-476d-8648-058991b142e5"}}}}, {"uuid": "a3ae50f4-d19a-4bfa-8ff0-1f84947d8884", "name": "", "x": 38.70348320380497, "y": -122.3754933077317, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e484d77-29ac-4903-afa3-f677283db883", "name": "p1rlv848", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a3ae50f4-d19a-4bfa-8ff0-1f84947d8884"}}}}, {"uuid": "dd460952-fe9a-4bfb-adf2-3abd1eaf4da5", "name": "", "x": 38.702921323422025, "y": -122.3755291486841, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "475b6a50-9814-4016-bb88-be5b1b2ac31d", "name": "p1rdt483lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dd460952-fe9a-4bfb-adf2-3abd1eaf4da5"}}}}, {"uuid": "b23389d5-db2a-42ee-8d67-2310f4899dc8", "name": "", "x": 38.703007845457876, "y": -122.37538641519177, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b053d449-b15b-4292-9a73-9b7d104a8e38", "name": "p1rlv845", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b23389d5-db2a-42ee-8d67-2310f4899dc8"}}}}, {"uuid": "240ea3e2-73c5-4635-bc37-fc108951680c", "name": "", "x": 38.70304524173173, "y": -122.37563909815356, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48b5535c-f00d-4b48-a23a-87f3f212302f", "name": "p1rlv851", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "240ea3e2-73c5-4635-bc37-fc108951680c"}}}}, {"uuid": "82a21e9b-7754-4024-88a0-ae654168e5df", "name": "", "x": 38.702817687028535, "y": -122.37521556434297, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5ea0f4f5-2024-45a8-9f8f-f5963e7d2727", "name": "p1rlv859", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "82a21e9b-7754-4024-88a0-ae654168e5df"}}}}, {"uuid": "669a2a11-e7f7-4f0e-b8c2-68e80fbec40b", "name": "", "x": 38.70279292587802, "y": -122.37564129224644, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "18ea7daf-9665-4d68-b255-12d41bdb2396", "name": "p1rdm892", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "669a2a11-e7f7-4f0e-b8c2-68e80fbec40b"}}}}, {"uuid": "5dc4e885-9a73-4f8e-b1ae-d50867b07dbb", "name": "", "x": 38.70291988195477, "y": -122.37578969289967, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "10611e08-75e2-4422-ac0f-cfb98c7eae4b", "name": "p1rlv855", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5dc4e885-9a73-4f8e-b1ae-d50867b07dbb"}}}}, {"uuid": "d4b2664f-dc7b-4cdb-b3b2-d960e5421cac", "name": "", "x": 38.70292245928232, "y": -122.37627268549726, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0398ef91-eeb8-4d34-b05e-e88adabdd487", "name": "p1rdm890", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d4b2664f-dc7b-4cdb-b3b2-d960e5421cac"}}}}, {"uuid": "2b9bff87-4eb3-4876-9012-61e1b232fe89", "name": "", "x": 38.703110285036146, "y": -122.37600654493566, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a95877ca-8600-4e95-82ac-c51cb82acf16", "name": "p1rlv849", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2b9bff87-4eb3-4876-9012-61e1b232fe89"}}}}, {"uuid": "9251def0-f2e1-4f6e-941b-d92daf95dca5", "name": "", "x": 38.703228109041184, "y": -122.37391642365674, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f396745a-5edb-4ab8-8bc7-2b181719cbf4", "name": "p1rdt484lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9251def0-f2e1-4f6e-941b-d92daf95dca5"}}}}, {"uuid": "49e501ea-9bde-4e92-adc9-d234bbe0089e", "name": "", "x": 38.703036634136346, "y": -122.3740291205105, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "283142ff-4884-4adc-9d4c-f8615505415a", "name": "p1rlv847", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "49e501ea-9bde-4e92-adc9-d234bbe0089e"}}}}, {"uuid": "fa8c24ff-8763-42d3-8d11-c9086c1ba728", "name": "", "x": 38.70327135825731, "y": -122.37410757698957, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e96e4c25-4664-45ae-b77c-9e0047f65c8b", "name": "p1rdm895", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa8c24ff-8763-42d3-8d11-c9086c1ba728"}}}}, {"uuid": "d321aa56-ea46-4547-b406-d12d6edaf433", "name": "", "x": 38.70311835119867, "y": -122.37414341195237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25f84b28-695b-4d32-b96c-914226444b9f", "name": "p1rlv856", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d321aa56-ea46-4547-b406-d12d6edaf433"}}}}, {"uuid": "7db6af4b-6a64-498f-a521-1854f01504d8", "name": "", "x": 38.703669352612835, "y": -122.37607068899858, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60637f4b-8538-4b21-988c-1b13adecc647", "name": "p1rdm896", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7db6af4b-6a64-498f-a521-1854f01504d8"}}}}, {"uuid": "b3c65356-acf8-47e2-8334-90564c73b6ca", "name": "", "x": 38.70391277989249, "y": -122.3760915746208, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f8d49057-9c70-4489-95bb-36b5b574e13d", "name": "p1rlv850", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b3c65356-acf8-47e2-8334-90564c73b6ca"}}}}, {"uuid": "e8a3be83-b908-4eb8-b9a2-4785c43e8598", "name": "", "x": 38.70359885298128, "y": -122.37627393150467, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "da38ec0a-f37d-4a5c-8da0-93410a8fb475", "name": "p1rdt485lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e8a3be83-b908-4eb8-b9a2-4785c43e8598"}}}}, {"uuid": "650cf4f4-5e7c-4f74-b727-66f7380cd60a", "name": "", "x": 38.703581080158116, "y": -122.37641646997498, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3464daa0-06b2-4d5d-9901-bb34050fe619", "name": "p1rdm897", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "650cf4f4-5e7c-4f74-b727-66f7380cd60a"}}}}, {"uuid": "42113e48-8448-48b0-9eb0-8fcced6b8af6", "name": "", "x": 38.703436102309, "y": -122.37626822341811, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "365eff25-8ccb-448b-894f-ad662fe6d684", "name": "p1rlv853", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "42113e48-8448-48b0-9eb0-8fcced6b8af6"}}}}, {"uuid": "05bc81c2-2d04-4cf3-a9a5-7f23fd30a9e3", "name": "", "x": 38.703390597071916, "y": -122.37449755221637, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9d9b6dee-73e1-43ab-ac9b-7d20fb77b6df", "name": "p1rdm898", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "05bc81c2-2d04-4cf3-a9a5-7f23fd30a9e3"}}}}, {"uuid": "7e983a28-7cb7-4af9-b2ce-4ffd390611f0", "name": "", "x": 38.70324715473682, "y": -122.37463680676714, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32142941-c546-4356-ba80-123b9128b5de", "name": "p1rlv852", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7e983a28-7cb7-4af9-b2ce-4ffd390611f0"}}}}, {"uuid": "897928d1-20b8-4749-8364-0b0632b5ca5a", "name": "", "x": 38.70348000850968, "y": -122.37489531232455, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5401d366-a5a2-4753-82b7-ce4fa08a1227", "name": "p1rdt486lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "897928d1-20b8-4749-8364-0b0632b5ca5a"}}}}, {"uuid": "4d064814-1c38-4d96-9a35-d3efdb32c61b", "name": "", "x": 38.70361123258167, "y": -122.37531216321483, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e5e11ab-e042-4038-85c4-162521871722", "name": "p1rdm899", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d064814-1c38-4d96-9a35-d3efdb32c61b"}}}}, {"uuid": "8ee66b9b-0ed0-4790-a55e-d4442e53b1b7", "name": "", "x": 38.703799916455935, "y": -122.3752070170666, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a28cc17a-125d-4b7b-a697-230e3f8853b5", "name": "p1rlv857", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8ee66b9b-0ed0-4790-a55e-d4442e53b1b7"}}}}, {"uuid": "738b4b76-6e5f-44ae-a070-587d3e0c8e90", "name": "", "x": 38.70291683599943, "y": -122.37353789637632, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "47fbd02f-6c12-4bd6-9d6d-2e0cddbfcd88", "name": "p1rdt487lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "738b4b76-6e5f-44ae-a070-587d3e0c8e90"}}}}, {"uuid": "db92746b-b776-4bb9-bdff-ba0791a8c89d", "name": "", "x": 38.702960786540345, "y": -122.373328259674, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2461b6f0-9a40-4b6f-9669-be479da039f3", "name": "p1rlv854", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "db92746b-b776-4bb9-bdff-ba0791a8c89d"}}}}, {"uuid": "eafb6508-d461-4b86-9216-758ab0e8ab85", "name": "", "x": 38.699795636236686, "y": -122.375786328938, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e517b810-e6b9-4c89-b47d-1921fcf88edc", "name": "p1rdt488lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eafb6508-d461-4b86-9216-758ab0e8ab85"}}}}, {"uuid": "b72997ac-862f-46db-a691-047ec1506a3f", "name": "", "x": 38.69977340921936, "y": -122.37552954904456, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "09a7be46-a1bf-459d-836b-beb64324809b", "name": "p1rlv863", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b72997ac-862f-46db-a691-047ec1506a3f"}}}}, {"uuid": "9b4b2a81-aca2-4dfe-b222-4bd3d89f2356", "name": "", "x": 38.699886904548684, "y": -122.37583204363513, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d7f4223-382b-4b9a-9157-baede39de271", "name": "p1rdm901", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9b4b2a81-aca2-4dfe-b222-4bd3d89f2356"}}}}, {"uuid": "d07a2474-09ad-4312-9dd3-89afa4b4b404", "name": "", "x": 38.699878813753116, "y": -122.37554765578757, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6a07d30f-6909-4d74-be8a-1ff8343b4419", "name": "p1rlv861", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d07a2474-09ad-4312-9dd3-89afa4b4b404"}}}}, {"uuid": "65525a66-1773-4ea2-b271-524a8bc99e2f", "name": "", "x": 38.69880247694915, "y": -122.37480953523237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25637062-8ca3-4694-a27b-7be93e89fe1f", "name": "p1rdt489lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65525a66-1773-4ea2-b271-524a8bc99e2f"}}}}, {"uuid": "3d4e34d0-f420-48ce-9811-dd970d236fa2", "name": "", "x": 38.698651585469364, "y": -122.37471132813891, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1fb4003d-498a-494d-89ca-f222d921f63a", "name": "p1rlv869", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3d4e34d0-f420-48ce-9811-dd970d236fa2"}}}}, {"uuid": "b6387c92-387a-45c9-87dc-051d39df6ccd", "name": "", "x": 38.759686999725254, "y": -122.44226913015365, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "601a7504-69fc-4c21-a1d8-1a59751d439c", "name": "p1rdm7860", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b6387c92-387a-45c9-87dc-051d39df6ccd"}}}}, {"uuid": "daba7bcc-f84f-4392-823d-cf77c8291e5e", "name": "", "x": 38.759611722163974, "y": -122.44160216619036, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fd7a84bb-8aa4-4668-9791-a363741823e9", "name": "p1rlv7783", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "daba7bcc-f84f-4392-823d-cf77c8291e5e"}}}}, {"uuid": "f417b4b4-aaed-4be9-aa1d-29ac29530106", "name": "", "x": 38.759987059360896, "y": -122.4422362456647, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8ae14df0-ab3b-47ba-9f83-c09f03999c76", "name": "p1rdt3776lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f417b4b4-aaed-4be9-aa1d-29ac29530106"}}}}, {"uuid": "3d1135bd-0816-4b36-bbc4-3735e50292b3", "name": "", "x": 38.760119212628396, "y": -122.44219670856471, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "391504f7-3b2f-47f0-aadd-47de5c89b16b", "name": "p1rdm7861", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3d1135bd-0816-4b36-bbc4-3735e50292b3"}}}}, {"uuid": "811d2f8e-757f-4164-9b75-2c45d474b794", "name": "", "x": 38.76011816883335, "y": -122.4419780350059, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "24e665a0-3ba6-46a7-bc02-327b6f77c409", "name": "p1rlv7784", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "811d2f8e-757f-4164-9b75-2c45d474b794"}}}}, {"uuid": "08c1e17d-fdf8-42ae-9eb9-e06c74feb269", "name": "", "x": 38.75891156323847, "y": -122.44466513486701, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4662f3f5-e75b-4b75-a6d6-7ada745d5cca", "name": "p1rdt3777lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "08c1e17d-fdf8-42ae-9eb9-e06c74feb269"}}}}, {"uuid": "44fc4fff-3b31-4f55-8b28-afc7b1803074", "name": "", "x": 38.75891004710453, "y": -122.44564742267218, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9af62e3c-9357-4505-a2f6-3b4252dab81b", "name": "p1rlv7786", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "44fc4fff-3b31-4f55-8b28-afc7b1803074"}}}}, {"uuid": "d07200f5-dcef-4fc8-b31d-44f9a58cb3af", "name": "", "x": 38.75892205855218, "y": -122.44438129888907, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "90158ee6-01aa-48ce-867f-8e459e7a5e09", "name": "p1rdm7862", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d07200f5-dcef-4fc8-b31d-44f9a58cb3af"}}}}, {"uuid": "2c94939f-e53a-4390-a61c-2fdeaf2224ef", "name": "", "x": 38.758813649325106, "y": -122.44432459271447, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1571d1a3-a151-4972-8cb1-aeb36b660abc", "name": "p1rlv7785", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2c94939f-e53a-4390-a61c-2fdeaf2224ef"}}}}, {"uuid": "2abed101-61b0-40f8-9656-14aa9bb44653", "name": "", "x": 38.665452782208654, "y": -122.46042242219686, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e734d7a2-9161-41c0-ba78-9f9f87120acd", "name": "p1rdt5098lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2abed101-61b0-40f8-9656-14aa9bb44653"}}}}, {"uuid": "349e93eb-bbeb-4cf6-962a-1da6b3e846fb", "name": "", "x": 38.66549109565642, "y": -122.46029967067366, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "09926231-b077-4aa6-afd8-acf89744865a", "name": "p1rlv10453", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "349e93eb-bbeb-4cf6-962a-1da6b3e846fb"}}}}, {"uuid": "ec821adf-cbe4-4f10-99c3-85668031f401", "name": "", "x": 38.665383753359855, "y": -122.46047289225729, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9a639e8d-ac8c-46e8-a4b5-6c551612b209", "name": "p1rlv10468", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ec821adf-cbe4-4f10-99c3-85668031f401"}}}}, {"uuid": "7096e027-1f66-45c2-8594-9b2f6171bb76", "name": "", "x": 38.665480227274244, "y": -122.45989744815324, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d40fc87f-1b73-4ed4-a397-dbc94312dcad", "name": "p1rlv10482", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7096e027-1f66-45c2-8594-9b2f6171bb76"}}}}, {"uuid": "1761a6d4-5d26-409e-b522-e6548258829b", "name": "", "x": 38.665521469030836, "y": -122.46102359049253, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "efd01236-6ba3-424e-829b-3f3950ce6265", "name": "p1rlv10517", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1761a6d4-5d26-409e-b522-e6548258829b"}}}}, {"uuid": "9dc653ac-d7a4-4f89-a699-b360eff11ffe", "name": "", "x": 38.65349301133138, "y": -122.48412729471077, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "91754be7-2a91-4a0e-9856-43d08ecc7c70", "name": "p1rdt5548lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9dc653ac-d7a4-4f89-a699-b360eff11ffe"}}}}, {"uuid": "32548a03-8760-4329-b730-0eb4180d6402", "name": "", "x": 38.65285475188867, "y": -122.48386195652688, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "773a6b9e-d708-4f7c-a901-9406bcc3dcde", "name": "p1rlv11503", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "32548a03-8760-4329-b730-0eb4180d6402"}}}}, {"uuid": "6daffc64-545f-48b6-b9dd-c01a7caf0cd9", "name": "", "x": 38.65294527277444, "y": -122.48395324626152, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f7efbb32-55d4-409b-a37f-bf01d0620d40", "name": "p1rlv19645", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6daffc64-545f-48b6-b9dd-c01a7caf0cd9"}}}}, {"uuid": "d52b4ce6-a2a9-4d89-b20c-badbd780ff8b", "name": "", "x": 38.65351451941317, "y": -122.48429393725958, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c4c77c78-e261-4d17-93ff-caad4d86246b", "name": "p1rdm11706", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d52b4ce6-a2a9-4d89-b20c-badbd780ff8b"}}}}, {"uuid": "5c8ae331-4dc1-4b73-8eb7-19d3d44f688f", "name": "", "x": 38.65313573125618, "y": -122.48422769840043, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9e90f763-682e-4771-976c-9cd736b72133", "name": "p1rlv19640", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5c8ae331-4dc1-4b73-8eb7-19d3d44f688f"}}}}, {"uuid": "e12efe67-ffe9-45e6-8d49-c58f292ff6e8", "name": "", "x": 38.65401139999537, "y": -122.48253201007375, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "15ae4af0-db43-4f1b-bd8c-c6be31d034aa", "name": "p1rdm11719", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e12efe67-ffe9-45e6-8d49-c58f292ff6e8"}}}}, {"uuid": "3ba0dc35-2b37-4a80-ade1-eac0f9902e85", "name": "", "x": 38.65384898920333, "y": -122.48248720829615, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "84b9d44e-2c8d-4cee-a9d2-327a41ab8dad", "name": "p1rlv11513", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3ba0dc35-2b37-4a80-ade1-eac0f9902e85"}}}}, {"uuid": "0bf7988f-5ebc-458b-826c-ec6efad5e132", "name": "", "x": 38.65406486613757, "y": -122.48238206755065, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "05b867e6-2f18-49e7-9869-55bd5048c201", "name": "p1rdt5557lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0bf7988f-5ebc-458b-826c-ec6efad5e132"}}}}, {"uuid": "dcf43b02-4298-41d4-ad1c-92d87578993e", "name": "", "x": 38.654054728485086, "y": -122.4821409504333, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "effa94d0-34ae-4cbe-b8da-fd1693d47b3a", "name": "p1rdm11720", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dcf43b02-4298-41d4-ad1c-92d87578993e"}}}}, {"uuid": "4931ad26-9e32-4cb4-85cd-f7485acc5477", "name": "", "x": 38.65329740432264, "y": -122.48206595565533, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bf457d88-958c-446a-9584-73be8c609bbe", "name": "p1rlv19574", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4931ad26-9e32-4cb4-85cd-f7485acc5477"}}}}, {"uuid": "f173e132-e022-46a1-b3cf-6fb8b348146f", "name": "", "x": 38.655212268996365, "y": -122.4810200626239, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d5838960-8556-4e4a-95e9-8ba9ffc85141", "name": "p1rdt5560lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f173e132-e022-46a1-b3cf-6fb8b348146f"}}}}, {"uuid": "edd6a9c5-95e0-4cbc-9328-cd8be4f904c6", "name": "", "x": 38.655330800417374, "y": -122.48132726741721, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "86d82a1e-1596-4fb3-9f3d-44c9553396d2", "name": "p1rlv11516", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "edd6a9c5-95e0-4cbc-9328-cd8be4f904c6"}}}}, {"uuid": "3fcef969-b8f3-49c8-ad03-1838c6eac971", "name": "", "x": 38.65375449158675, "y": -122.48352206240394, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "133a0221-0cd5-46d2-af84-e80e7951c96d", "name": "p1rdt5561lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3fcef969-b8f3-49c8-ad03-1838c6eac971"}}}}, {"uuid": "5a41b4bf-e666-4b1b-834e-521504b72b04", "name": "", "x": 38.65442296031636, "y": -122.48389667390005, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "179d1d84-0dfe-4920-a039-009f33bc1d8d", "name": "p1rlv11517", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5a41b4bf-e666-4b1b-834e-521504b72b04"}}}}, {"uuid": "2f613491-2ee1-4f3f-9d9a-e20f2d3640a5", "name": "", "x": 38.65445021577995, "y": -122.48126863552662, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8deb73b9-51fc-447d-9da7-14a6dccff646", "name": "p1rdt5564lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2f613491-2ee1-4f3f-9d9a-e20f2d3640a5"}}}}, {"uuid": "5397d76e-8423-4b26-b76a-ed3deff45a7c", "name": "", "x": 38.65452001830409, "y": -122.48139057750333, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f8f0f8a2-f528-45bd-8fbd-22f6699fe7e0", "name": "p1rlv11521", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5397d76e-8423-4b26-b76a-ed3deff45a7c"}}}}, {"uuid": "d1eb9046-a524-4a94-b3ce-001d80998cd8", "name": "", "x": 38.653503595754145, "y": -122.48459005947156, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "95a5450a-6630-41b8-863f-0c1f3fcfa7ab", "name": "p1rdt5566lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1eb9046-a524-4a94-b3ce-001d80998cd8"}}}}, {"uuid": "c57fc713-783d-4b5e-a8bc-8461f19caa7a", "name": "", "x": 38.652722315413676, "y": -122.48448349500988, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "69eba934-3f80-4abc-b5e8-9cdc79aa05a3", "name": "p1rlv11523", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c57fc713-783d-4b5e-a8bc-8461f19caa7a"}}}}, {"uuid": "bb4f6529-f339-4286-bf82-44fc21a9adef", "name": "", "x": 38.65290868561374, "y": -122.48312227902461, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "613d178b-a566-408d-bad0-e4a170eea971", "name": "p1rdt5568lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bb4f6529-f339-4286-bf82-44fc21a9adef"}}}}, {"uuid": "317c2a79-f30d-438a-93a0-556de85f2806", "name": "", "x": 38.65290346928153, "y": -122.48306882713341, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b97ebb0-09a4-4c42-a10e-e3aff344aa44", "name": "p1rlv11526", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "317c2a79-f30d-438a-93a0-556de85f2806"}}}}, {"uuid": "aff86a89-8b6f-444c-a1a3-218129998f5b", "name": "", "x": 38.6535709305957, "y": -122.48453866803233, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0460a67f-dcc1-4829-99f8-7a0b6a8cedbc", "name": "p1rdm11742", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aff86a89-8b6f-444c-a1a3-218129998f5b"}}}}, {"uuid": "3e312389-c9f7-417a-be1e-7d41819eff67", "name": "", "x": 38.652965879895014, "y": -122.48453921146539, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "21b18539-fba6-4b52-b8bf-38c2a6c4abfb", "name": "p1rlv11533", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e312389-c9f7-417a-be1e-7d41819eff67"}}}}, {"uuid": "f3df1aff-a25f-42fd-82d9-c0e51c70bc8f", "name": "", "x": 38.65330877367878, "y": -122.48464018641775, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8f0e181a-fa89-4c5d-a1cb-6080f91331da", "name": "p1rlv19643", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f3df1aff-a25f-42fd-82d9-c0e51c70bc8f"}}}}, {"uuid": "6e5af62d-2fbe-4dfd-b7d1-8a1040a5ab7e", "name": "", "x": 38.65345372369736, "y": -122.48479084547154, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "248e065d-80ed-4926-9625-295c83da6b61", "name": "p1rdt5574lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6e5af62d-2fbe-4dfd-b7d1-8a1040a5ab7e"}}}}, {"uuid": "981c76fc-50f5-4e40-ae36-c33893f91beb", "name": "", "x": 38.65346288080924, "y": -122.48484594711942, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6554d73d-5cf7-4531-a524-78e70b36fd8d", "name": "p1rdm11743", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "981c76fc-50f5-4e40-ae36-c33893f91beb"}}}}, {"uuid": "365c2b7e-424c-4246-8ec1-4d1f39dbbcbb", "name": "", "x": 38.65324635107003, "y": -122.48479003561559, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "813f887e-6807-4ffc-90bf-bd30cde9a9df", "name": "p1rlv19610", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "365c2b7e-424c-4246-8ec1-4d1f39dbbcbb"}}}}, {"uuid": "e1ac22f0-6134-44d1-8d4f-f2948df6203a", "name": "", "x": 38.65211076864418, "y": -122.48360342410952, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "21ef4ae6-b80e-49f1-8d00-1cb6e27bc8f9", "name": "p1rdt5577lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e1ac22f0-6134-44d1-8d4f-f2948df6203a"}}}}, {"uuid": "c8697d6c-15d8-4c61-a6de-4f056fdb7afb", "name": "", "x": 38.65211742852992, "y": -122.48423500000004, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1148946c-8c37-4482-afce-5082cd2b7ad4", "name": "p1rdt5577lv-p1rlv11540x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c8697d6c-15d8-4c61-a6de-4f056fdb7afb"}}}}, {"uuid": "53948b43-71df-47cc-80ba-c157d05bf7d7", "name": "", "x": 38.65207242155051, "y": -122.48424681497777, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f79b14c8-e77d-49c1-9336-e7407ad4c94d", "name": "p1rlv11540", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "53948b43-71df-47cc-80ba-c157d05bf7d7"}}}}, {"uuid": "2a1c2b55-25ee-42cc-8a93-81ebf49aae00", "name": "", "x": 38.65279916105022, "y": -122.4835175838475, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "752bcf04-7a44-42b0-9a46-44c243b78eb5", "name": "p1rdt5577lv-p1rlv19608x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2a1c2b55-25ee-42cc-8a93-81ebf49aae00"}}}}, {"uuid": "bcf33a8f-8984-4542-a3db-d89c5f01df6e", "name": "", "x": 38.652193358258536, "y": -122.48306224209226, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f917b142-d59f-4a51-8c3b-913feb53411d", "name": "p1rlv19608", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bcf33a8f-8984-4542-a3db-d89c5f01df6e"}}}}, {"uuid": "4483501b-cdce-4aa1-833e-1d89f54498eb", "name": "", "x": 38.66703472717699, "y": -122.47875999417263, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a5559c15-cdac-4a4d-a2a0-b99c9befb310", "name": "p1rdm13355", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4483501b-cdce-4aa1-833e-1d89f54498eb"}}}}, {"uuid": "8e65ba3a-d5dc-4516-9dcc-39816f28eb6c", "name": "", "x": 38.666963198566314, "y": -122.47888695389291, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1564c5f9-8b80-41b4-af09-2a55dee0718b", "name": "p1rlv13033", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8e65ba3a-d5dc-4516-9dcc-39816f28eb6c"}}}}, {"uuid": "358567fb-7670-4972-bc4a-8361e82ef171", "name": "", "x": 38.66717310843214, "y": -122.47884342821176, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a9859b30-0238-493e-be1a-cb6717413ba9", "name": "p1rdt6261lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "358567fb-7670-4972-bc4a-8361e82ef171"}}}}, {"uuid": "9605bc5c-3d00-4414-ba84-af1384312959", "name": "", "x": 38.667278908257714, "y": -122.47895363367641, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ba5e6363-0b23-4726-8013-f3d040511005", "name": "p1rdm13356", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9605bc5c-3d00-4414-ba84-af1384312959"}}}}, {"uuid": "d06077af-253f-4440-a72d-e4097453ec3e", "name": "", "x": 38.66717220353242, "y": -122.4792762580999, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "23aae8f1-8b9f-4453-9643-b49ffdc80889", "name": "p1rlv13036", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d06077af-253f-4440-a72d-e4097453ec3e"}}}}, {"uuid": "1edf8d84-7823-4da1-a9cf-7d60fa171495", "name": "", "x": 38.66655673727605, "y": -122.48006632205775, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c2172b57-622b-44c1-8388-f1e2b1def312", "name": "p1rdt6262lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1edf8d84-7823-4da1-a9cf-7d60fa171495"}}}}, {"uuid": "e08f8ab0-1195-4113-aad2-d08a9ef594fb", "name": "", "x": 38.66654421125099, "y": -122.47991300856037, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3b7bff1-90da-4ee2-8a0f-8e291a7e8ac8", "name": "p1rlv13034", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e08f8ab0-1195-4113-aad2-d08a9ef594fb"}}}}, {"uuid": "cc8e6a88-7c99-4b4d-a6a2-b5b5983b91f3", "name": "", "x": 38.66654838989604, "y": -122.48021581199129, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c6839f65-9d3b-4bd6-89a4-0c8feb33e98a", "name": "p1rlv13040", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc8e6a88-7c99-4b4d-a6a2-b5b5983b91f3"}}}}, {"uuid": "ff16a8d5-a522-4782-b3a5-3bae4ab23764", "name": "", "x": 38.66690377458573, "y": -122.48086176489268, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4717b000-fd39-4647-9fbd-5152323dacee", "name": "p1rdt6263lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ff16a8d5-a522-4782-b3a5-3bae4ab23764"}}}}, {"uuid": "1220e772-0453-4a0b-b571-cc0a62841ce9", "name": "", "x": 38.66687779947186, "y": -122.48081912313049, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c6d309ef-b082-4022-a265-4891cdcd6db9", "name": "p1rlv13035", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1220e772-0453-4a0b-b571-cc0a62841ce9"}}}}, {"uuid": "03fd6629-3635-4d50-8480-1e1e39c348ec", "name": "", "x": 38.66255558019544, "y": -122.47741013877915, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e916c16-525d-4092-b627-ad44b4bf4ee8", "name": "p1rdt6264lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "03fd6629-3635-4d50-8480-1e1e39c348ec"}}}}, {"uuid": "5b083b59-faa7-407f-94c6-95a8fb7db4e9", "name": "", "x": 38.66254447908395, "y": -122.47746230770055, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7f5d04aa-74fb-4d1a-ac91-6c01a56a94b5", "name": "p1rlv13037", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5b083b59-faa7-407f-94c6-95a8fb7db4e9"}}}}, {"uuid": "f42abcc6-9394-4f6f-afa6-91874259a980", "name": "", "x": 38.66061026704863, "y": -122.48036217979423, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e6bb5544-e583-4ded-9a10-23be70f5598e", "name": "p1rdt6265lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f42abcc6-9394-4f6f-afa6-91874259a980"}}}}, {"uuid": "c47455e5-7a81-46e7-8b23-13a1b138d9b2", "name": "", "x": 38.660735364357585, "y": -122.48075957945385, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9a8b4502-31fd-4dce-8717-9860880075b4", "name": "p1rlv13038", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c47455e5-7a81-46e7-8b23-13a1b138d9b2"}}}}, {"uuid": "768cb989-5a66-410d-bed8-df0e10c19744", "name": "", "x": 38.660452382345134, "y": -122.47994557664096, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "34d43081-e4a3-4f1b-8b90-5965458452d0", "name": "p1rlv13039", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "768cb989-5a66-410d-bed8-df0e10c19744"}}}}, {"uuid": "c00988a8-164a-4ae9-87ff-eda2c2eb1e48", "name": "", "x": 38.66246119968208, "y": -122.47659512275703, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8af5f9d5-965c-4a0c-a811-67d3bed744ee", "name": "p1rdt6266lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c00988a8-164a-4ae9-87ff-eda2c2eb1e48"}}}}, {"uuid": "c8e8dfff-c156-4d84-b476-8dbf65fb2e45", "name": "", "x": 38.66248671917567, "y": -122.47655203872152, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60144ce1-d4d6-4725-b543-f881894356a5", "name": "p1rlv13041", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c8e8dfff-c156-4d84-b476-8dbf65fb2e45"}}}}, {"uuid": "62fb1dd6-10cf-453b-a9db-bf538e6415e4", "name": "", "x": 38.6652765486321, "y": -122.4794367281912, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d0ddd898-3193-4bff-80f4-fd4a7eae9aec", "name": "p1rdt6267lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "62fb1dd6-10cf-453b-a9db-bf538e6415e4"}}}}, {"uuid": "74b1a318-c73f-40ae-a0e6-13095293a6a8", "name": "", "x": 38.665302069155366, "y": -122.47939364345397, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "296cd07e-c2e3-4031-abad-9c870a65105d", "name": "p1rlv13042", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "74b1a318-c73f-40ae-a0e6-13095293a6a8"}}}}, {"uuid": "f4e4a449-0026-4c8d-b73e-666ad21ff0e4", "name": "", "x": 38.64756555827549, "y": -122.50910380696413, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b1155c2c-544c-45f4-969f-b3ec4f6773bb", "name": "p1rdt6488lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f4e4a449-0026-4c8d-b73e-666ad21ff0e4"}}}}, {"uuid": "941c708e-42ff-43af-9af5-da57099f33ff", "name": "", "x": 38.647565542168486, "y": -122.50904985776398, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3243ca2f-a97e-4fbc-981d-85eded2e5e6b", "name": "p1rlv13513", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "941c708e-42ff-43af-9af5-da57099f33ff"}}}}, {"uuid": "59de6cf1-c8b9-4799-9a3e-2d4543e023f1", "name": "", "x": 38.66460136270918, "y": -122.44791156272083, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "555453a3-3fb7-426a-bbd2-9e588d4bd01d", "name": "p1rdt6578lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59de6cf1-c8b9-4799-9a3e-2d4543e023f1"}}}}, {"uuid": "73222e13-9809-4b5b-b542-81f2e9da8236", "name": "", "x": 38.66482282070209, "y": -122.4484080912382, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b0ca6e47-afec-4d61-885a-e38176b32444", "name": "p1rlv13823", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "73222e13-9809-4b5b-b542-81f2e9da8236"}}}}, {"uuid": "89f1ffe4-82cc-44f4-b229-a1afaf6f6224", "name": "", "x": 38.66450541345186, "y": -122.44798523933892, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b2fe65b3-6fcc-4416-bca4-9a0f6551b801", "name": "p1rdm14192", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "89f1ffe4-82cc-44f4-b229-a1afaf6f6224"}}}}, {"uuid": "3480b5cb-c591-42d2-9162-b0b478d1a56f", "name": "", "x": 38.664643133522475, "y": -122.44852441239391, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "47a7519a-b550-41e6-99e3-c2115db425fe", "name": "p1rlv13789", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3480b5cb-c591-42d2-9162-b0b478d1a56f"}}}}, {"uuid": "05f1416d-d004-448f-b835-8e7320ea9e88", "name": "", "x": 38.664533911991846, "y": -122.4482953651979, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "94ac9254-cdbf-4864-b22b-bcfb0a827700", "name": "p1rlv13796", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "05f1416d-d004-448f-b835-8e7320ea9e88"}}}}, {"uuid": "91603163-b327-419b-a562-9c486068b876", "name": "", "x": 38.66474807177311, "y": -122.44784544493244, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e0be7c1-65b8-4de4-89f2-56b6bf1ea321", "name": "p1rdm14194", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "91603163-b327-419b-a562-9c486068b876"}}}}, {"uuid": "51acf417-9cd8-46f7-97c9-1dcf69d8d859", "name": "", "x": 38.664827245819765, "y": -122.44803626546826, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "028d5ead-7c34-400b-bcc1-c4d706c965d3", "name": "p1rlv13814", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "51acf417-9cd8-46f7-97c9-1dcf69d8d859"}}}}, {"uuid": "99ed1f5c-706f-4524-beb7-df5068132667", "name": "", "x": 38.66661910169782, "y": -122.45155134514903, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5de250a8-ecca-4ab4-9f09-685aaf92d13d", "name": "p1rdt6580lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "99ed1f5c-706f-4524-beb7-df5068132667"}}}}, {"uuid": "c929ea7a-c3b7-4391-8edc-8285bd035f71", "name": "", "x": 38.666738131523914, "y": -122.4513475088475, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "251f270f-4238-4fe6-8ab3-f884fca7a42d", "name": "p1rlv13791", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c929ea7a-c3b7-4391-8edc-8285bd035f71"}}}}, {"uuid": "b64d8094-1b15-4af2-acb7-1e043d25b76f", "name": "", "x": 38.66668551808711, "y": -122.45165826434774, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ab29ca66-d59b-4aa6-b5f6-165add0bc331", "name": "p1rlv13810", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b64d8094-1b15-4af2-acb7-1e043d25b76f"}}}}, {"uuid": "52721818-3941-4aff-9668-b15d64e4bdbd", "name": "", "x": 38.666731383536465, "y": -122.45183033352055, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "99957459-46a6-4b2b-9813-69b11ca7dad1", "name": "p1rlv13815", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "52721818-3941-4aff-9668-b15d64e4bdbd"}}}}, {"uuid": "247043b9-09d5-4c87-b578-344fd897a004", "name": "", "x": 38.66641388074643, "y": -122.4513844669654, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "36c12a74-a2ca-439a-a69f-308dd5cb1207", "name": "p1rlv13819", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "247043b9-09d5-4c87-b578-344fd897a004"}}}}, {"uuid": "ea0e7b78-57d9-4a45-8c88-1895800c3377", "name": "", "x": 38.66518206185532, "y": -122.44754723338062, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4d944119-3782-49dd-8b24-1f68d8ee687c", "name": "p1rdt6584lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea0e7b78-57d9-4a45-8c88-1895800c3377"}}}}, {"uuid": "d1cbf045-63a5-47f4-8bc1-deba3702bf62", "name": "", "x": 38.66553515936385, "y": -122.4484945814938, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e96bcc5b-07c5-4289-aec4-0224395c5e8a", "name": "p1rlv13817", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1cbf045-63a5-47f4-8bc1-deba3702bf62"}}}}, {"uuid": "a2f9db05-7e24-4244-8ad2-e1510b25c7d1", "name": "", "x": 38.664864895136674, "y": -122.44777558197904, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "39af24f1-0fa2-465e-a288-2b620d9e9d59", "name": "p1rdm14215", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a2f9db05-7e24-4244-8ad2-e1510b25c7d1"}}}}, {"uuid": "feda626a-d10e-404b-8da3-429c769d4502", "name": "", "x": 38.66522828205339, "y": -122.4483934862407, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "accec892-a236-462d-b714-1178393ec992", "name": "p1rlv13801", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "feda626a-d10e-404b-8da3-429c769d4502"}}}}, {"uuid": "8c3e1a23-2e50-4e2b-bd42-b64588a6a090", "name": "", "x": 38.66526883647157, "y": -122.44743914288946, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32db643a-7c82-4816-8629-7935cab09567", "name": "p1rdm14218", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8c3e1a23-2e50-4e2b-bd42-b64588a6a090"}}}}, {"uuid": "3993ede8-b98b-4f7e-8582-45a688300ddf", "name": "", "x": 38.66568002523225, "y": -122.4480376675357, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6ade9991-a857-4619-8094-c18f824aaeb9", "name": "p1rlv13822", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3993ede8-b98b-4f7e-8582-45a688300ddf"}}}}, {"uuid": "c957710d-5b59-48d4-a705-163d7bef81c0", "name": "", "x": 38.665376485198, "y": -122.44733486613728, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e81f150f-30cd-4c9a-b5b7-7a633633702d", "name": "p1rdm14216", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c957710d-5b59-48d4-a705-163d7bef81c0"}}}}, {"uuid": "0640235f-69e2-44df-a002-75850f23e028", "name": "", "x": 38.66561322577763, "y": -122.44785029518839, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c26fba44-3b81-47de-81e6-522f2daf0534", "name": "p1rlv13807", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0640235f-69e2-44df-a002-75850f23e028"}}}}, {"uuid": "9a67951a-5d21-4aaf-8cf1-055c0e9b6ed4", "name": "", "x": 38.6660700064695, "y": -122.44833835279438, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9c587698-7940-4edb-9105-f31f1304f7e9", "name": "p1rdt6587lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9a67951a-5d21-4aaf-8cf1-055c0e9b6ed4"}}}}, {"uuid": "94a40471-e692-4c82-9db0-8a67ada7ed7d", "name": "", "x": 38.66604401958438, "y": -122.44829572341504, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1c795ac7-3b49-4158-996d-2fb1f0337847", "name": "p1rlv13808", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "94a40471-e692-4c82-9db0-8a67ada7ed7d"}}}}, {"uuid": "fa34ac6d-08b7-48d7-a2f6-0fb2f91ccd62", "name": "", "x": 38.665782733034895, "y": -122.44688743442987, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "61045f72-ca3d-4e0d-ac3d-db5fbf099b38", "name": "p1rdt6588lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa34ac6d-08b7-48d7-a2f6-0fb2f91ccd62"}}}}, {"uuid": "18f4c8ab-3825-40dd-ae7c-e806892501d8", "name": "", "x": 38.66551610253854, "y": -122.44636826305491, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "687996da-ab03-4544-b0d9-b79b8ac88e95", "name": "p1rlv13809", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "18f4c8ab-3825-40dd-ae7c-e806892501d8"}}}}, {"uuid": "774d8c44-6377-428c-89ae-01326c5972f4", "name": "", "x": 38.66470818578833, "y": -122.44621086682648, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a289017a-8ab9-4412-857a-694b3aa2c63d", "name": "p1rdt6590lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "774d8c44-6377-428c-89ae-01326c5972f4"}}}}, {"uuid": "aca2fbd4-467d-4bf7-8341-2b23f9d30c2b", "name": "", "x": 38.66472254581389, "y": -122.44626167635215, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a2caa70b-9143-4676-834b-bfc7cb41330c", "name": "p1rlv13820", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aca2fbd4-467d-4bf7-8341-2b23f9d30c2b"}}}}, {"uuid": "51a9a4f7-cb5d-4fe5-9213-71fe12585bae", "name": "", "x": 38.66450288065584, "y": -122.44662624081425, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8a7c2e99-857f-4119-be4a-daaca586f056", "name": "p1rdt6591lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "51a9a4f7-cb5d-4fe5-9213-71fe12585bae"}}}}, {"uuid": "bd002735-2c22-4505-9f8a-7fed31956b37", "name": "", "x": 38.664476893151246, "y": -122.44658361298364, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "66e6c732-919a-4851-9f76-5580ea71669d", "name": "p1rlv13821", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bd002735-2c22-4505-9f8a-7fed31956b37"}}}}, {"uuid": "53ce4353-6591-4b16-8c1b-6a572722d9d2", "name": "", "x": 38.650925590961236, "y": -122.47648370205337, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8ad975da-cce7-49cb-be78-20c4abf8975e", "name": "p1rdt7286lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "53ce4353-6591-4b16-8c1b-6a572722d9d2"}}}}, {"uuid": "1f533a6b-7428-41c4-9100-81e5b64c526d", "name": "", "x": 38.65091178622824, "y": -122.47653475192051, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "17bf6d8f-8215-4294-b921-cc3e34476f1e", "name": "p1rlv15585", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1f533a6b-7428-41c4-9100-81e5b64c526d"}}}}, {"uuid": "7bd1bc68-a2a4-45a5-8c9c-3c8b6a13e850", "name": "", "x": 38.650690731688435, "y": -122.47687130836174, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "56d21681-3c57-4575-af17-f2bbf9874a10", "name": "p1rdt7289lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7bd1bc68-a2a4-45a5-8c9c-3c8b6a13e850"}}}}, {"uuid": "ab2a10f9-9b8c-4c25-a988-03a6d071f099", "name": "", "x": 38.6509152754639, "y": -122.47733687713344, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ef2a4478-4644-4bd3-9548-ab1d0be338b5", "name": "p1rlv15590", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ab2a10f9-9b8c-4c25-a988-03a6d071f099"}}}}, {"uuid": "9baa86b9-b0df-4541-ad87-bc928134642d", "name": "", "x": 38.650433450846926, "y": -122.47639803350314, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c04c9ad1-4277-47de-9cec-9ce86e17b4f1", "name": "p1rlv15591", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9baa86b9-b0df-4541-ad87-bc928134642d"}}}}, {"uuid": "c5d952d0-6fca-404d-bafd-c21da4301161", "name": "", "x": 38.64948736383664, "y": -122.47579982496423, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a9b0c16f-f433-4aa1-8d00-dc1573dfb5e3", "name": "p1rdt7293lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c5d952d0-6fca-404d-bafd-c21da4301161"}}}}, {"uuid": "90c36dbe-020f-474a-abb4-c1e99f474701", "name": "", "x": 38.64940610565797, "y": -122.47576594155083, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "629e2259-2a59-4b20-b8bf-7b3b2c4a48f9", "name": "p1rlv15595", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "90c36dbe-020f-474a-abb4-c1e99f474701"}}}}, {"uuid": "cee60e10-1306-4dec-9856-0151cfeda93e", "name": "", "x": 38.64955676013305, "y": -122.47582982129457, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "af6b7d1b-896f-44ac-8038-748c74507253", "name": "p1rlv15598", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cee60e10-1306-4dec-9856-0151cfeda93e"}}}}, {"uuid": "15fe8ec5-07e2-4234-a2a7-51372760b4ae", "name": "", "x": 38.654450185149294, "y": -122.50266398158654, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2c1ea087-8a4d-49ca-af35-b86aed849c98", "name": "p1rdm16003", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "15fe8ec5-07e2-4234-a2a7-51372760b4ae"}}}}, {"uuid": "a779adaf-c56f-4ee1-b671-6b1ebacd5ed8", "name": "", "x": 38.65486320126965, "y": -122.50230485132435, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1ae1bbf1-459f-4346-b525-393b7d1dc958", "name": "p1rlv15599", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a779adaf-c56f-4ee1-b671-6b1ebacd5ed8"}}}}, {"uuid": "6c968024-4d09-403e-8de9-24c501753797", "name": "", "x": 38.65438386391856, "y": -122.5025685251368, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e67d2b31-f05a-4160-83ae-55154224a9ca", "name": "p1rdt7294lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c968024-4d09-403e-8de9-24c501753797"}}}}, {"uuid": "3a8505e3-0148-40ca-8dea-f61cc48f9601", "name": "", "x": 38.65435022729933, "y": -122.50246929784952, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "84040096-aca8-4cee-8539-83ae8f875e98", "name": "p1rdm16004", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3a8505e3-0148-40ca-8dea-f61cc48f9601"}}}}, {"uuid": "1214be7e-500a-4096-ad98-58bc00c5743b", "name": "", "x": 38.65468208995729, "y": -122.50209923605257, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "200aa7d8-0a43-4086-b0e7-f63cae75671d", "name": "p1rlv15618", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1214be7e-500a-4096-ad98-58bc00c5743b"}}}}, {"uuid": "fb368e45-5c62-4a91-958e-6df0c1eec86a", "name": "", "x": 38.653703111752435, "y": -122.50076138596326, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "381018f1-11cd-4519-ad24-d3419116ea84", "name": "p1rdm16011", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fb368e45-5c62-4a91-958e-6df0c1eec86a"}}}}, {"uuid": "eb97ab60-a0ad-46ff-81c6-1ab952ef9d01", "name": "", "x": 38.653216389940184, "y": -122.5007417792492, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "95b45d46-b7e7-46e2-98d9-5034e2fa0a17", "name": "p1rlv15604", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eb97ab60-a0ad-46ff-81c6-1ab952ef9d01"}}}}, {"uuid": "6432a19e-5501-4437-a6b0-cd8612d69898", "name": "", "x": 38.65369179013314, "y": -122.5008839086118, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4cee417a-3410-4907-8621-f0d3fcbc047c", "name": "p1rdt7299lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6432a19e-5501-4437-a6b0-cd8612d69898"}}}}, {"uuid": "799f4d77-24d9-4527-bf0a-c0834026128f", "name": "", "x": 38.653722262619546, "y": -122.50102558146277, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60d0a9cf-54f3-4049-9957-29839b7beb08", "name": "p1rdm16012", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "799f4d77-24d9-4527-bf0a-c0834026128f"}}}}, {"uuid": "ff26d6fb-1052-422a-81b1-50b88edd8bbd", "name": "", "x": 38.65323563888248, "y": -122.5010289572013, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "43ed408e-35e2-4bca-9060-a0c211aea1e7", "name": "p1rlv15616", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ff26d6fb-1052-422a-81b1-50b88edd8bbd"}}}}, {"uuid": "dc6d07f1-791e-4b94-9a88-dbf295621c02", "name": "", "x": 38.65171836396122, "y": -122.5073219402769, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "135a6a49-6562-4c6e-a41f-f5f78c0ac3e6", "name": "p1rdt7300lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dc6d07f1-791e-4b94-9a88-dbf295621c02"}}}}, {"uuid": "d1113cbb-086c-48b3-8046-8852b680c9f0", "name": "", "x": 38.65167635588258, "y": -122.5073274367839, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dcbee2ff-bf73-4834-bc3c-46fa0cfcad7c", "name": "p1rlv15605", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1113cbb-086c-48b3-8046-8852b680c9f0"}}}}, {"uuid": "dd0c9180-337b-4bc7-a31a-2e7577171c37", "name": "", "x": 38.65243771052424, "y": -122.50266243015153, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7cbc8145-b198-46f1-a3fd-55a05637e618", "name": "p1rdt7303lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dd0c9180-337b-4bc7-a31a-2e7577171c37"}}}}, {"uuid": "73ce9fe1-705c-4d8e-80a9-5002c8210d4b", "name": "", "x": 38.65185163082318, "y": -122.5019234602924, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "13d6bce6-9066-43a1-b2b6-00a2a4398958", "name": "p1rlv15608", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "73ce9fe1-705c-4d8e-80a9-5002c8210d4b"}}}}, {"uuid": "c3756008-99bf-4ec0-be53-adb1369cb151", "name": "", "x": 38.65403878438859, "y": -122.50195031171204, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f5094655-6494-44a9-b0ff-c5b418dcc11e", "name": "p1rdt7308lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c3756008-99bf-4ec0-be53-adb1369cb151"}}}}, {"uuid": "381a41d9-1504-45db-8a4a-b27efaca3000", "name": "", "x": 38.65437369075951, "y": -122.50163017248886, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "905a4857-5d3d-4e51-9ab0-70d634170f92", "name": "p1rlv15619", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "381a41d9-1504-45db-8a4a-b27efaca3000"}}}}, {"uuid": "4fbcffd8-86e8-496d-a8d0-357e53dacafa", "name": "", "x": 38.65414032051154, "y": -122.50185014901611, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4363602a-eb9c-41b8-8130-7bb839f4eb5a", "name": "p1rlv15641", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4fbcffd8-86e8-496d-a8d0-357e53dacafa"}}}}, {"uuid": "8d28b870-3e9d-4d30-9b6a-31be9b81e034", "name": "", "x": 38.65415951784417, "y": -122.50212583870878, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2fba947f-089b-47f3-8720-e8f3e35c097c", "name": "p1rdm16029", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8d28b870-3e9d-4d30-9b6a-31be9b81e034"}}}}, {"uuid": "6011a0aa-03d4-41bc-9cd5-35dc2c621d40", "name": "", "x": 38.65402792759886, "y": -122.50230311224807, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "13f790a1-18c0-498f-8525-fbaf0350947b", "name": "p1rlv15623", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6011a0aa-03d4-41bc-9cd5-35dc2c621d40"}}}}, {"uuid": "7bcce16d-87e0-4d10-8d57-fc5b8f524a87", "name": "", "x": 38.65396880738655, "y": -122.5017823813949, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "154999cc-f6d5-458a-8504-e4692344d372", "name": "p1rdm16030", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7bcce16d-87e0-4d10-8d57-fc5b8f524a87"}}}}, {"uuid": "ced6ff7a-a03f-4dbf-af5e-aade5a1de2b0", "name": "", "x": 38.654067738651435, "y": -122.50173572574505, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bb08eda2-b277-4bfd-9ea0-9c36765400bd", "name": "p1rlv15625", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ced6ff7a-a03f-4dbf-af5e-aade5a1de2b0"}}}}, {"uuid": "ada35336-5f78-4415-b3ea-9cc7c7352964", "name": "", "x": 38.65379214946685, "y": -122.49984533771044, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a289e26d-2d86-4fdf-942b-881b91ca18eb", "name": "p1rdt7316lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ada35336-5f78-4415-b3ea-9cc7c7352964"}}}}, {"uuid": "f1c90b98-2c9f-413b-b598-8e9a43a467cb", "name": "", "x": 38.653302578004016, "y": -122.49982178319588, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ccbef4c-6bf7-4892-a3b9-b51aca495137", "name": "p1rlv15632", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f1c90b98-2c9f-413b-b598-8e9a43a467cb"}}}}, {"uuid": "9249d58e-8a76-44e5-ab7a-bbf6e295e37f", "name": "", "x": 38.65235598284797, "y": -122.5051810906482, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16c465cf-c4ae-4702-ba6c-0b7704eda764", "name": "p1rdt7317lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9249d58e-8a76-44e5-ab7a-bbf6e295e37f"}}}}, {"uuid": "4cde1297-67a1-4116-829e-576e190346d1", "name": "", "x": 38.65233001653422, "y": -122.50513844857348, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ce7b60c8-43ee-441d-9f18-5b2722dcc0a7", "name": "p1rlv15633", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4cde1297-67a1-4116-829e-576e190346d1"}}}}, {"uuid": "36a11850-ce0c-4dc2-9025-e1a728e855f8", "name": "", "x": 38.65388017043282, "y": -122.50146517734701, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c855f7bb-1f33-4c3e-9deb-e3f9c5aba07d", "name": "p1rdt7321lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "36a11850-ce0c-4dc2-9025-e1a728e855f8"}}}}, {"uuid": "70d3109c-f76c-4c96-a280-3e806f70f125", "name": "", "x": 38.654218486038864, "y": -122.50116005048001, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "83c2de51-1b04-483c-8ce7-14b9e5e027b9", "name": "p1rlv15640", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "70d3109c-f76c-4c96-a280-3e806f70f125"}}}}, {"uuid": "540b9bcf-c9d5-4cb2-8966-7c8b6f1c4e02", "name": "", "x": 38.65226101532919, "y": -122.47461094321253, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35be767a-53a1-4fe1-b320-9542dd859d97", "name": "p1rdt7737lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "540b9bcf-c9d5-4cb2-8966-7c8b6f1c4e02"}}}}, {"uuid": "9128b7b1-69e3-423d-ab24-0b8fb59a92b2", "name": "", "x": 38.652194262671, "y": -122.47453893224326, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f5f1e7aa-d93a-4164-8bc0-f920259304a8", "name": "p1rlv16450", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9128b7b1-69e3-423d-ab24-0b8fb59a92b2"}}}}, {"uuid": "45717d17-588c-4eb9-a4be-b1c9e571652a", "name": "", "x": 38.65248920521251, "y": -122.47462474258207, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d9c505d7-3fb9-4eb5-89c6-c9c8da32fd05", "name": "p1rlv16463", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "45717d17-588c-4eb9-a4be-b1c9e571652a"}}}}, {"uuid": "0576c8e0-7b96-4420-b9f8-447650c20d43", "name": "", "x": 38.652235798683144, "y": -122.47438525528987, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "27afe70a-9123-4b0c-9f50-b5355aafcf7a", "name": "p1rlv16507", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0576c8e0-7b96-4420-b9f8-447650c20d43"}}}}, {"uuid": "ea134be6-84da-486d-a0fb-15deb4c9bca9", "name": "", "x": 38.652238275903315, "y": -122.4749368672296, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "344c6b21-94c9-4912-a19e-69fbae5eed27", "name": "p1rlv16584", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea134be6-84da-486d-a0fb-15deb4c9bca9"}}}}, {"uuid": "82e95af2-0e57-4cfe-9c63-c699df52bc84", "name": "", "x": 38.65261600612352, "y": -122.47400628819638, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c7482f0c-eb85-4e30-a09a-eb9f15bbc22b", "name": "p1rdt7753lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "82e95af2-0e57-4cfe-9c63-c699df52bc84"}}}}, {"uuid": "f0d43a70-8ec5-408b-bb0e-9092293d6456", "name": "", "x": 38.652627105759464, "y": -122.4739541259785, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d400b1b2-8404-4b80-b110-6f96e000314f", "name": "p1rlv16475", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f0d43a70-8ec5-408b-bb0e-9092293d6456"}}}}, {"uuid": "83cbec58-3089-49b8-91b1-3572e4a05cab", "name": "", "x": 38.658298169770895, "y": -122.47497347035102, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d343e634-0936-4f21-9e2c-079e19f0dfa1", "name": "p1rdt7757lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "83cbec58-3089-49b8-91b1-3572e4a05cab"}}}}, {"uuid": "b74099d8-228c-463c-a617-41b1b8d455ef", "name": "", "x": 38.65825842964543, "y": -122.47499635592735, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fa6db7ee-126d-4aa9-9733-35ff1c1d5992", "name": "p1rlv16483", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b74099d8-228c-463c-a617-41b1b8d455ef"}}}}, {"uuid": "05f73af5-dbf7-4f27-99c1-3a2dcde31799", "name": "", "x": 38.65819457523532, "y": -122.47482442341177, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0333a34b-4027-4d9a-9d4a-f867c8a317bc", "name": "p1rlv16530", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "05f73af5-dbf7-4f27-99c1-3a2dcde31799"}}}}, {"uuid": "9256eb4c-375b-42f1-8ad0-bcc74e8ae8d9", "name": "", "x": 38.658358587646056, "y": -122.4752254901639, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2f7be042-6681-4694-872d-a1cb701016c7", "name": "p1rlv16541", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9256eb4c-375b-42f1-8ad0-bcc74e8ae8d9"}}}}, {"uuid": "55908553-18e6-47d5-8215-e9cf09c30dea", "name": "", "x": 38.65188446678294, "y": -122.47516262760837, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "28e5f84f-2fac-4b5c-a669-b16988e4d6ae", "name": "p1rdt7791lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "55908553-18e6-47d5-8215-e9cf09c30dea"}}}}, {"uuid": "3e84f813-0859-4f02-bd54-f544f2df4bd7", "name": "", "x": 38.65192675650909, "y": -122.47516097998692, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "90d9dbe9-f9c9-4a4e-8ada-cb459778687b", "name": "p1rlv16573", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e84f813-0859-4f02-bd54-f544f2df4bd7"}}}}, {"uuid": "04928077-4f80-411d-97b8-360cb32be1a4", "name": "", "x": 38.65926840087407, "y": -122.47227383933975, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3959f944-18f5-4daa-a454-3c6bfb7158ff", "name": "p1rdt7795lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "04928077-4f80-411d-97b8-360cb32be1a4"}}}}, {"uuid": "1c69b90b-d0e1-4028-b482-1ca4036e8cc5", "name": "", "x": 38.659242422649335, "y": -122.47223120521224, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4f9ecb3f-8b64-4598-a9d1-d794c6800d33", "name": "p1rlv16604", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1c69b90b-d0e1-4028-b482-1ca4036e8cc5"}}}}, {"uuid": "3a49aadf-859f-4e49-b74b-d23355a7ffe5", "name": "", "x": 38.65559599442719, "y": -122.48692988350368, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b2ec0ba-a854-4631-b97a-4674123d6fe6", "name": "p1rdt8105lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3a49aadf-859f-4e49-b74b-d23355a7ffe5"}}}}, {"uuid": "4ed7c063-ce74-4874-bf3b-1cec6aacd6f6", "name": "", "x": 38.65559859235702, "y": -122.4868763747223, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ba567aae-a893-41d3-8fd1-8357d3cab35d", "name": "p1rlv17239", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ed7c063-ce74-4874-bf3b-1cec6aacd6f6"}}}}, {"uuid": "8ded3db0-024b-49be-9acc-a695799cecde", "name": "", "x": 38.65564415406407, "y": -122.48699097808593, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ac80cbea-e10a-491a-ba36-06e9fcf74217", "name": "p1rlv17280", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8ded3db0-024b-49be-9acc-a695799cecde"}}}}, {"uuid": "e0f12590-98d4-4ed7-88fc-5fa5e8fe6dff", "name": "", "x": 38.65331243461887, "y": -122.48752476984971, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d3a01639-0851-466b-abc6-adf52342e772", "name": "p1rdm17827", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e0f12590-98d4-4ed7-88fc-5fa5e8fe6dff"}}}}, {"uuid": "e1d2445b-e46e-4799-9c98-9252d8c2b600", "name": "", "x": 38.652961085543296, "y": -122.48755025792832, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "acfdbe95-2d82-463a-9d1f-6fd2688adf16", "name": "p1rlv17246", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e1d2445b-e46e-4799-9c98-9252d8c2b600"}}}}, {"uuid": "1bb45f7b-4b3a-4a44-9f4d-3048f9a15419", "name": "", "x": 38.65328712796407, "y": -122.48771232590543, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b639e55-2e33-4582-bb96-06a9d33a3419", "name": "p1rdt8111lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1bb45f7b-4b3a-4a44-9f4d-3048f9a15419"}}}}, {"uuid": "7da01a9e-f940-4a01-ac34-2a764e845b0c", "name": "", "x": 38.653333923034495, "y": -122.48782204194723, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5f70da59-a879-487b-802e-6b7158e425ca", "name": "p1rdm17828", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7da01a9e-f940-4a01-ac34-2a764e845b0c"}}}}, {"uuid": "a34da1cb-8ad8-4e47-b317-055a6b86c735", "name": "", "x": 38.65282666757047, "y": -122.4877236014364, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "04eb7e32-e372-4cb0-94a7-ee418f400bda", "name": "p1rlv17303", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a34da1cb-8ad8-4e47-b317-055a6b86c735"}}}}, {"uuid": "494046db-61b9-449a-9a55-d9608b0d5234", "name": "", "x": 38.65208064789989, "y": -122.48678276121687, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dca9b40e-ed8a-4f75-a703-91539f6c3075", "name": "p1rdt8138lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "494046db-61b9-449a-9a55-d9608b0d5234"}}}}, {"uuid": "7c64b2fd-a133-4a8c-9fcb-743e9393fa45", "name": "", "x": 38.65203864087114, "y": -122.4867882697381, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "04388b89-16fc-40b3-a060-5bc52032874e", "name": "p1rlv17291", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7c64b2fd-a133-4a8c-9fcb-743e9393fa45"}}}}, {"uuid": "1088c6d5-a0f6-4aec-b76a-562b554e8ef7", "name": "", "x": 38.65325699793473, "y": -122.48785970145335, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2bee3961-990e-47ac-b49b-d305f8fe0af8", "name": "p1rdt8146lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1088c6d5-a0f6-4aec-b76a-562b554e8ef7"}}}}, {"uuid": "56ebb882-ddef-4c87-b835-7a021bf78079", "name": "", "x": 38.65356656926306, "y": -122.48793668955402, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "84ebd9bb-dc50-483d-a3c6-044682d4020c", "name": "p1rlv17311", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "56ebb882-ddef-4c87-b835-7a021bf78079"}}}}, {"uuid": "c69bb444-8523-4fdb-99e3-e8c089f4c256", "name": "", "x": 38.66673594751398, "y": -122.46980033939064, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa", "name": "p1rdt8167lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c69bb444-8523-4fdb-99e3-e8c089f4c256"}}}}, {"uuid": "b5629075-98c4-481e-8592-5d57793c505c", "name": "", "x": 38.66651447553529, "y": -122.46928074240148, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8ead5953-70f2-4db2-ba4d-d203c91d85c1", "name": "p1rlv17345", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b5629075-98c4-481e-8592-5d57793c505c"}}}}, {"uuid": "098d3ef0-d2ce-45d0-b04b-b6fa2a56d0b0", "name": "", "x": 38.66618245827339, "y": -122.4695935453166, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf6f74e5-7aa3-4333-bd37-3ce486d54a01", "name": "p1rlv17357", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "098d3ef0-d2ce-45d0-b04b-b6fa2a56d0b0"}}}}, {"uuid": "688ea7b2-7e09-464c-9685-92079311bc8a", "name": "", "x": 38.6673297300225, "y": -122.47020579507135, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d38cdffb-41be-48aa-8a03-c6525dd01037", "name": "p1rlv17397", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "688ea7b2-7e09-464c-9685-92079311bc8a"}}}}, {"uuid": "3dc7dadf-fb8b-4fe0-bf61-9116073c4629", "name": "", "x": 38.66639617857814, "y": -122.46902873548488, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "63177299-2842-4e0d-bf17-7bd2b0afe9a2", "name": "p1rlv17400", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3dc7dadf-fb8b-4fe0-bf61-9116073c4629"}}}}, {"uuid": "ad90541b-98b5-45cd-aea6-3f4573d2327e", "name": "", "x": 38.66678976962103, "y": -122.47037069875277, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b50de14e-9a09-4f61-8998-0979f33b0d0a", "name": "p1rlv17405", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ad90541b-98b5-45cd-aea6-3f4573d2327e"}}}}, {"uuid": "43488034-d332-485e-b8da-3a24da45e181", "name": "", "x": 38.66709595196411, "y": -122.47032246448548, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "86b2527b-73c3-41c4-8ac2-7cb0e8bc2a7a", "name": "p1rlv17415", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "43488034-d332-485e-b8da-3a24da45e181"}}}}, {"uuid": "ff26a39a-d362-48b4-b352-4a4d2839995a", "name": "", "x": 38.66477303429095, "y": -122.46767335323095, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6349165a-d47a-4cf4-84f9-df5c5f3a0e98", "name": "p1rdt8169lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ff26a39a-d362-48b4-b352-4a4d2839995a"}}}}, {"uuid": "443ccb79-9a64-4ac3-b93f-fa60e82b93dd", "name": "", "x": 38.66481200983204, "y": -122.467465715666, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d98640c6-d8aa-44e4-9ecf-5998152d3f7d", "name": "p1rlv17347", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "443ccb79-9a64-4ac3-b93f-fa60e82b93dd"}}}}, {"uuid": "f004f264-53e5-4fd1-8448-926cf4132117", "name": "", "x": 38.664771291883746, "y": -122.46842004356215, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2695decb-d268-46b2-8604-9c33dc90518b", "name": "p1rlv17351", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f004f264-53e5-4fd1-8448-926cf4132117"}}}}, {"uuid": "21b4086a-2833-4014-96f2-2209265c8dbd", "name": "", "x": 38.66479314943949, "y": -122.4672819466205, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9d61897a-cdac-4b4a-8812-8a8692a3d958", "name": "p1rlv17403", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "21b4086a-2833-4014-96f2-2209265c8dbd"}}}}, {"uuid": "f0bd1e1c-ade2-43ea-875c-2be47a63315b", "name": "", "x": 38.661451147924325, "y": -122.47380185053476, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4903e82a-8cfb-406e-b4bf-5e01068419a3", "name": "p1rdt8174lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f0bd1e1c-ade2-43ea-875c-2be47a63315b"}}}}, {"uuid": "56156265-30ca-4fec-b4a3-d59a1ce3950c", "name": "", "x": 38.66119075710339, "y": -122.4737681067613, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f34e3e4e-bebd-4148-bcc7-cbfbecd73a2f", "name": "p1rlv17353", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "56156265-30ca-4fec-b4a3-d59a1ce3950c"}}}}, {"uuid": "8e5ea8b0-2606-496e-b62b-336950b8c3ad", "name": "", "x": 38.66166044070652, "y": -122.47400603929611, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "08709e25-b030-4801-ae00-c4879556d8b1", "name": "p1rlv17378", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8e5ea8b0-2606-496e-b62b-336950b8c3ad"}}}}, {"uuid": "20ce5bab-71b6-436d-abd2-2689fe8b4c7c", "name": "", "x": 38.66156929181106, "y": -122.47377683037024, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e1ad135-904d-47ed-ae74-32b38e1c2f88", "name": "p1rlv17383", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "20ce5bab-71b6-436d-abd2-2689fe8b4c7c"}}}}, {"uuid": "b0fbd10a-9771-4bd7-8373-783698ea0919", "name": "", "x": 38.66528062582966, "y": -122.47017186379257, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e8e03b63-853e-4cfe-bf4a-3779b2026637", "name": "p1rdt8180lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b0fbd10a-9771-4bd7-8373-783698ea0919"}}}}, {"uuid": "51433068-e7bc-4d85-ab18-651de34b6f21", "name": "", "x": 38.665280591504875, "y": -122.4701179030113, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c705333f-6f1a-4a76-a02e-eaa859e99b70", "name": "p1rlv17361", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "51433068-e7bc-4d85-ab18-651de34b6f21"}}}}, {"uuid": "689be9de-1a3d-4405-9fc9-4e242c05dec8", "name": "", "x": 38.66045657865189, "y": -122.47345917790395, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "782d6008-7fec-46b6-9461-9e33b79539d3", "name": "p1rdt8195lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "689be9de-1a3d-4405-9fc9-4e242c05dec8"}}}}, {"uuid": "cb0259a5-54e7-49a0-9eda-41e167976f9b", "name": "", "x": 38.66053224527863, "y": -122.47362350869747, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e835b413-3307-49ef-ad69-cf18a5ae7cfb", "name": "p1rlv17385", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb0259a5-54e7-49a0-9eda-41e167976f9b"}}}}, {"uuid": "1a251dab-2e8e-4c18-aeec-e3ad49945911", "name": "", "x": 38.660557365368454, "y": -122.47319806082461, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "55382019-a1a5-40fd-b90a-072af40c2258", "name": "p1rlv17387", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1a251dab-2e8e-4c18-aeec-e3ad49945911"}}}}, {"uuid": "2a87817d-94cb-4638-8c68-d8fc549cb84a", "name": "", "x": 38.66087354418496, "y": -122.47336814960953, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "169a22de-bb0a-4056-8910-151125c4ff9e", "name": "p1rlv17391", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2a87817d-94cb-4638-8c68-d8fc549cb84a"}}}}, {"uuid": "7e225669-7357-4c5f-a6b8-e6c959f1a8d3", "name": "", "x": 38.66027039448875, "y": -122.47351048965503, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "65de341c-589f-4bf9-a708-26fcc94a6c0a", "name": "p1rlv17407", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7e225669-7357-4c5f-a6b8-e6c959f1a8d3"}}}}, {"uuid": "b9619af0-f534-4ed8-b443-1108e70cd926", "name": "", "x": 38.66016282543937, "y": -122.47363770635508, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "67003f0f-6690-469e-82c0-63949ee5241e", "name": "p1rlv17417", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b9619af0-f534-4ed8-b443-1108e70cd926"}}}}, {"uuid": "1d442fee-a8d8-44b1-b273-76993ff7d240", "name": "", "x": 38.66642010101456, "y": -122.47095566992769, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "76e33e4f-05be-44d1-a503-fed82b4da974", "name": "p1rdt8201lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d442fee-a8d8-44b1-b273-76993ff7d240"}}}}, {"uuid": "fb83ab4d-1060-4dd9-9f30-4b8f22cb1510", "name": "", "x": 38.66660266134409, "y": -122.47084335519723, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ea560bcb-f930-4f42-ae45-3a60f36fdbb7", "name": "p1rlv17394", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fb83ab4d-1060-4dd9-9f30-4b8f22cb1510"}}}}, {"uuid": "48c5cddc-037d-4d5b-b65a-c400b0f007e8", "name": "", "x": 38.66627923556136, "y": -122.47106413182223, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "64a56527-23a9-4229-aa25-f6a45f2187f4", "name": "p1rlv17416", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "48c5cddc-037d-4d5b-b65a-c400b0f007e8"}}}}, {"uuid": "cb371e53-908c-4a9f-a2b4-4fac71dc0dec", "name": "", "x": 38.658114052272616, "y": -122.48189066352298, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8c1f6cd8-cde1-45cc-87ca-1355efa38077", "name": "p1rdt9055lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb371e53-908c-4a9f-a2b4-4fac71dc0dec"}}}}, {"uuid": "76473ac2-56a8-4fac-a4da-1dbaf863b311", "name": "", "x": 38.658139573766896, "y": -122.48184758396665, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be1b9922-2426-4726-9e5a-bcd33f444b57", "name": "p1rlv19616", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "76473ac2-56a8-4fac-a4da-1dbaf863b311"}}}}, {"uuid": "4dc345dd-f015-495c-886a-f88a38d01b1d", "name": "", "x": 38.65791058099435, "y": -122.46275595471984, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "afb4c195-8bb6-47d5-88f3-76adb9cda250", "name": "p1rdt9086lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4dc345dd-f015-495c-886a-f88a38d01b1d"}}}}, {"uuid": "9c47b247-8e1b-4242-9fa7-3d602fc71749", "name": "", "x": 38.657936095394604, "y": -122.46271286857773, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "19894180-0890-4585-b4e2-55500af3c41a", "name": "p1rlv19683", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9c47b247-8e1b-4242-9fa7-3d602fc71749"}}}}, {"uuid": "78134a20-f557-4c7c-bdfc-f58d76af56d2", "name": "", "x": 38.69033987948928, "y": -122.31517238474055, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "40b03cbe-470d-493a-854a-900557ac20c8", "name": "p1rdt16394lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "78134a20-f557-4c7c-bdfc-f58d76af56d2"}}}}, {"uuid": "c5989fcd-1f6f-4491-88d2-00fe769d047a", "name": "", "x": 38.690138170140635, "y": -122.31563821475763, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f827fe9e-1ffe-456c-a57b-c3374aef8ad8", "name": "p1rlv37689", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c5989fcd-1f6f-4491-88d2-00fe769d047a"}}}}, {"uuid": "f89b95b1-f645-487d-b039-3554fc023a6f", "name": "", "x": 38.69038758916915, "y": -122.3151414107498, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "da3cd593-6f05-41ba-9609-f6f1e307e998", "name": "p1rlv37691", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f89b95b1-f645-487d-b039-3554fc023a6f"}}}}, {"uuid": "c45145a7-e48a-45a9-b733-91ed9471b83f", "name": "", "x": 38.690565522935835, "y": -122.31474877047064, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "01c9efda-0adf-4932-8f54-2938964371d2", "name": "p1rlv37703", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c45145a7-e48a-45a9-b733-91ed9471b83f"}}}}, {"uuid": "065fe856-5120-4d7c-96e9-00c8304e4ee3", "name": "", "x": 38.68956634076771, "y": -122.30929268806497, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "38b0bd7c-0898-497f-bb24-4add0fd92932", "name": "p1rdt16404lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "065fe856-5120-4d7c-96e9-00c8304e4ee3"}}}}, {"uuid": "f48745c0-959b-4078-b13d-3e5d27fd30a0", "name": "", "x": 38.68932901734512, "y": -122.30982786050683, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "38bda697-2888-467e-bab0-62896a62503f", "name": "p1rlv37710", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f48745c0-959b-4078-b13d-3e5d27fd30a0"}}}}, {"uuid": "a534a629-8809-4af4-8251-f12881581d93", "name": "", "x": 38.68985442947351, "y": -122.30876497515673, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f8d998a0-628e-4009-a6c8-07af906f6d43", "name": "p1rlv37732", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a534a629-8809-4af4-8251-f12881581d93"}}}}, {"uuid": "f671dd9e-c96a-4c72-a7f2-32b8324f73df", "name": "", "x": 38.71319629081823, "y": -122.2618537891679, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "58dce206-0571-4a37-b24b-2e674e0c0d3b", "name": "p1rdm37174", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f671dd9e-c96a-4c72-a7f2-32b8324f73df"}}}}, {"uuid": "3dc216d4-8c44-41bb-a2eb-0d33315315ef", "name": "", "x": 38.713341484062944, "y": -122.26201332345111, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b24da1e-9a6e-4545-9ad4-a9f0e9675fd1", "name": "p1rlv37776", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3dc216d4-8c44-41bb-a2eb-0d33315315ef"}}}}, {"uuid": "0344c586-dfad-4b14-85d0-f6ac8106e33a", "name": "", "x": 38.71333206265715, "y": -122.26149980897426, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "23775c66-0b90-443d-8566-491405876e9d", "name": "p1rdt16424lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0344c586-dfad-4b14-85d0-f6ac8106e33a"}}}}, {"uuid": "990f60d2-63fa-4bd2-86bb-fd9b7e60eaad", "name": "", "x": 38.713372298566235, "y": -122.26118486465606, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d21a9584-0fe7-48a6-a46e-ac33e948a471", "name": "p1rdm37175", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "990f60d2-63fa-4bd2-86bb-fd9b7e60eaad"}}}}, {"uuid": "f5b8af75-ea5b-40bf-ba70-84760d41fac7", "name": "", "x": 38.71352621311042, "y": -122.26129830022444, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f5aaed5d-8312-4707-a047-634e433bf49f", "name": "p1rlv37778", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5b8af75-ea5b-40bf-ba70-84760d41fac7"}}}}, {"uuid": "72f2febe-f3c7-4987-8225-28831e04951b", "name": "", "x": 38.71269200809747, "y": -122.26236108033618, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "980376ed-54fd-434c-b58e-0bbd6eaa9954", "name": "p1rdt16427lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "72f2febe-f3c7-4987-8225-28831e04951b"}}}}, {"uuid": "16355f17-6818-4e54-8516-4c17b62d5f1e", "name": "", "x": 38.71269522836307, "y": -122.26242253360313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0d7181ee-ef64-4ded-b619-00ac09d55bf5", "name": "p1rlv37782", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "16355f17-6818-4e54-8516-4c17b62d5f1e"}}}}, {"uuid": "ba848da2-4966-44bb-878b-7dc0e31f2430", "name": "", "x": 38.684304380145115, "y": -122.31768680277943, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "26bc650a-6838-4320-8afa-b8d2f22e96e8", "name": "p1rdt16603lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ba848da2-4966-44bb-878b-7dc0e31f2430"}}}}, {"uuid": "dcfb8e68-db83-4b06-a59d-4820b9154406", "name": "", "x": 38.68458254841867, "y": -122.31796762036473, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "10be49a0-301a-4c7e-8ab7-49c14e483079", "name": "p1rlv38046", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dcfb8e68-db83-4b06-a59d-4820b9154406"}}}}, {"uuid": "bb368911-48db-4b83-b838-5c483aa7c0a3", "name": "", "x": 38.68382003837408, "y": -122.31702058531167, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0935a86b-b9fb-4058-8381-a41f67d6c9dd", "name": "p1rlv38047", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bb368911-48db-4b83-b838-5c483aa7c0a3"}}}}, {"uuid": "fd245f8b-6db6-41f1-b94c-9b6191e22523", "name": "", "x": 38.684447916688484, "y": -122.31806087736241, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9db6122d-1e51-46ac-9cea-ac436e189cd8", "name": "p1rlv38052", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fd245f8b-6db6-41f1-b94c-9b6191e22523"}}}}, {"uuid": "867a88ab-030c-47f8-8e55-ba767e4fd31c", "name": "", "x": 38.68318595308261, "y": -122.31906558684712, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d31da07-e20a-4fb8-95f4-d91450395471", "name": "p1rdt16604lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "867a88ab-030c-47f8-8e55-ba767e4fd31c"}}}}, {"uuid": "a92bf90f-f106-4803-b7cd-a94b7ec6a0e7", "name": "", "x": 38.68325558877688, "y": -122.31912993455164, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5da7ff68-5f4c-4d56-88fc-7736df03c0bf", "name": "p1rlv38048", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a92bf90f-f106-4803-b7cd-a94b7ec6a0e7"}}}}, {"uuid": "1be34c71-cd62-4229-a445-4640d75a7920", "name": "", "x": 38.683074628268045, "y": -122.31900518071453, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cafc6c03-240d-499d-a3d8-983b554dd007", "name": "p1rlv38050", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1be34c71-cd62-4229-a445-4640d75a7920"}}}}, {"uuid": "85f3f994-ebf6-4123-8306-7c66f4fe90fe", "name": "", "x": 38.72488522966494, "y": -122.31175617505791, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a4a3b828-bddf-4314-b9a5-03b9dfcd2618", "name": "p1rdt16787lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "85f3f994-ebf6-4123-8306-7c66f4fe90fe"}}}}, {"uuid": "4cb84e15-fc68-4ec5-ab40-cf063445d1c9", "name": "", "x": 38.72480906566549, "y": -122.31154585900022, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a25b3511-86cf-404e-944f-273d3f94c05a", "name": "p1rlv38414", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4cb84e15-fc68-4ec5-ab40-cf063445d1c9"}}}}, {"uuid": "a1e6aa75-b873-4007-a204-cf87e0d543ff", "name": "", "x": 38.724919569400605, "y": -122.3119474333546, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a6e4595c-0ad9-4501-b86f-c559917d4b86", "name": "p1rlv38419", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a1e6aa75-b873-4007-a204-cf87e0d543ff"}}}}, {"uuid": "37841bc9-c1dc-4418-bcb3-7309b15e549c", "name": "", "x": 38.725467899287466, "y": -122.31258369528427, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9c261090-bc22-4d81-9a9e-75227cd7c99e", "name": "p1rdt16790lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "37841bc9-c1dc-4418-bcb3-7309b15e549c"}}}}, {"uuid": "788ddba8-11aa-4aa0-8e92-f9c2adc10b3d", "name": "", "x": 38.725441863299416, "y": -122.312541080781, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "201112bb-3dc7-4a15-9af6-155626ac1ae5", "name": "p1rlv38417", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "788ddba8-11aa-4aa0-8e92-f9c2adc10b3d"}}}}, {"uuid": "5793a67e-5c04-4b95-ba75-d4fe24c7dea9", "name": "", "x": 38.69566612075781, "y": -122.29850531296424, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e1abef1d-4ffc-4696-91ca-e81ac36cce61", "name": "p1rdt16847lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5793a67e-5c04-4b95-ba75-d4fe24c7dea9"}}}}, {"uuid": "a380a296-2b02-4d46-bfde-f814f84ed80a", "name": "", "x": 38.695297864066646, "y": -122.29823690772227, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a0764c32-4f46-473a-9a72-cccc45ae28d7", "name": "p1rlv38535", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a380a296-2b02-4d46-bfde-f814f84ed80a"}}}}, {"uuid": "14b0b62d-7296-422d-9cc1-708bd7167a8c", "name": "", "x": 38.69607606503067, "y": -122.29876976693473, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5ff930f9-63f0-4cab-b74a-3db7eb99f9eb", "name": "p1rlv38536", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "14b0b62d-7296-422d-9cc1-708bd7167a8c"}}}}, {"uuid": "4d757316-db89-48f9-b906-07965b862b6a", "name": "", "x": 38.74356263285725, "y": -122.27336627842594, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0df1550a-7e69-42e9-8059-3a36ecb3d253", "name": "p1rdt16911lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d757316-db89-48f9-b906-07965b862b6a"}}}}, {"uuid": "28b52fe4-3ee2-48fe-9797-05cbf31832d3", "name": "", "x": 38.74357721508068, "y": -122.27335107450713, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4a3851f7-2dd3-447b-918f-7a8c954f21d1", "name": "p1rlv38638", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "28b52fe4-3ee2-48fe-9797-05cbf31832d3"}}}}, {"uuid": "752654c3-b2fa-4808-8238-2c2cfff7aadc", "name": "", "x": 38.67909765473299, "y": -122.51997053087246, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d49257c8-f8eb-4024-9c02-461d18cdd3d5", "name": "p1rdt383", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "752654c3-b2fa-4808-8238-2c2cfff7aadc"}}}}, {"uuid": "46aeb7f3-d13e-4a01-8839-fdd865ccf46d", "name": "", "x": 38.67949973700607, "y": -122.52574842403467, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8d8cd980-268f-4adb-a6ee-70edf7784542", "name": "p1rdt383-p1rdt384x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "46aeb7f3-d13e-4a01-8839-fdd865ccf46d"}}}}, {"uuid": "a23443c6-1d62-4ffa-9f5b-5736dfcce6aa", "name": "", "x": 38.6790657111712, "y": -122.52914676125815, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7adf2f4b-f0fd-4c53-abcf-d90fe1a2b4c4", "name": "p1rdt384", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a23443c6-1d62-4ffa-9f5b-5736dfcce6aa"}}}}, {"uuid": "90950951-2a50-4431-b77b-57d9b3dbe8c7", "name": "", "x": 38.651801942472055, "y": -122.5073324871614, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f9240d01-bf5d-41ed-8c53-c1f04af1a236", "name": "p1rdt383-p1rdt7300x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "90950951-2a50-4431-b77b-57d9b3dbe8c7"}}}}, {"uuid": "4d44044a-2d92-4b3c-9aab-774930b93609", "name": "", "x": 38.65515241674437, "y": -122.50889970027711, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e5ac1506-77e9-4b90-ad3d-18be099063a9", "name": "p1rdt383-p1rdt7300x_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d44044a-2d92-4b3c-9aab-774930b93609"}}}}, {"uuid": "05fc9700-79a2-4dc4-bf3d-f5de2a903094", "name": "", "x": 38.653733535353965, "y": -122.50089156658129, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d065da7b-7e88-4e63-a47c-959f4d4c6e1c", "name": "p1rdt7299", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "05fc9700-79a2-4dc4-bf3d-f5de2a903094"}}}}, {"uuid": "c914feb5-e9de-422b-aeaf-cfc62dd17293", "name": "", "x": 38.65375040418197, "y": -122.49983768034305, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6322bf4d-0976-4bae-94c0-f76f83ccb9bf", "name": "p1rdt7316", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c914feb5-e9de-422b-aeaf-cfc62dd17293"}}}}, {"uuid": "ab222d15-220f-49d0-9978-7493ba856d51", "name": "", "x": 38.65383842524826, "y": -122.5014575190295, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b468be25-1324-46ab-9424-887741ca1134", "name": "p1rdt7321", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ab222d15-220f-49d0-9978-7493ba856d51"}}}}, {"uuid": "9819f669-9c19-41ec-86fe-e3a06b9a4003", "name": "", "x": 38.65408052954152, "y": -122.50195797033598, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d2e605b4-fe7a-4571-947d-8ae19de627d8", "name": "p1rdt7308", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9819f669-9c19-41ec-86fe-e3a06b9a4003"}}}}, {"uuid": "dd3454db-2254-4e87-a37a-95cfce8f56ef", "name": "", "x": 38.65442560903119, "y": -122.50257618415456, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a955da2d-e212-4026-b1fb-0021a04ded07", "name": "p1rdt7294", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dd3454db-2254-4e87-a37a-95cfce8f56ef"}}}}, {"uuid": "27154954-bf7a-47cd-b84f-cfe43e152146", "name": "", "x": 38.652479455643565, "y": -122.5026700890289, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e6f24e3a-088a-4d1b-8292-03015289d88e", "name": "p1rdt7303", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "27154954-bf7a-47cd-b84f-cfe43e152146"}}}}, {"uuid": "ac160d78-43c2-4240-98f5-e6ae472758ac", "name": "", "x": 38.652370317308936, "y": -122.50523190353242, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48efebbb-c70a-47d3-aae3-0e39088fc455", "name": "p1rdt7317", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ac160d78-43c2-4240-98f5-e6ae472758ac"}}}}, {"uuid": "03e38011-c0fb-4e11-9933-4cd3cac852ba", "name": "", "x": 38.65220758039855, "y": -122.50510436245315, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e9980c6-3edc-4b4a-be98-cec731419c30", "name": "p1rdt7303-p1rdt7317x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "03e38011-c0fb-4e11-9933-4cd3cac852ba"}}}}, {"uuid": "5860e8c6-343d-4d04-bad2-41ef009e292b", "name": "", "x": 38.65176065727734, "y": -122.50732046975546, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "05f14a3e-053e-4b65-b962-da7804b9e2c1", "name": "p1rdt7300", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5860e8c6-343d-4d04-bad2-41ef009e292b"}}}}, {"uuid": "07ba29a5-2151-46cd-a5ab-f359ec3ab19c", "name": "", "x": 38.64755417890137, "y": -122.50920989641365, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "47f8ed28-4bff-47d9-8ffe-4509e9c5b7fc", "name": "p1rdt6488-p1rdt7300x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "07ba29a5-2151-46cd-a5ab-f359ec3ab19c"}}}}, {"uuid": "2f8c22fe-e901-48d9-9eef-46f361d4dc9c", "name": "", "x": 38.64759956755727, "y": -122.50867546400877, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b96c1e20-68ac-4548-a068-86483c7fa921", "name": "p1rdt6488-p1rdt7300xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2f8c22fe-e901-48d9-9eef-46f361d4dc9c"}}}}, {"uuid": "0840458c-3040-4065-b329-753f2e9edfff", "name": "", "x": 38.659282749601154, "y": -122.47232465037078, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bee93ff6-6ff8-4572-b339-c8e897dac81b", "name": "p1rdt7795", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0840458c-3040-4065-b329-753f2e9edfff"}}}}, {"uuid": "218dc36b-329c-4f26-a80d-dc68a2c4a6cc", "name": "", "x": 38.65789678232331, "y": -122.46280701212554, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75ee3b24-7407-45ba-94d5-abe187306f13", "name": "p1rdt9086", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "218dc36b-329c-4f26-a80d-dc68a2c4a6cc"}}}}, {"uuid": "ead0976b-5a32-4ecb-90c0-3f17d38fc9bf", "name": "", "x": 38.6582588467901, "y": -122.47506760778616, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0cd22d3e-1e2a-4a99-9967-b9df95837915", "name": "p1rdt7757-p1rdt7795x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ead0976b-5a32-4ecb-90c0-3f17d38fc9bf"}}}}, {"uuid": "575a3212-4155-4852-a5f4-bb331a4bbb26", "name": "", "x": 38.66713136194248, "y": -122.47883578171474, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "53e5fee4-5a31-448e-8bd0-d8996468d085", "name": "p1rdt6261", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "575a3212-4155-4852-a5f4-bb331a4bbb26"}}}}, {"uuid": "c526aa31-5e92-4d33-af90-0c67bd587449", "name": "", "x": 38.66662516142702, "y": -122.47987793918193, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6c00c7b1-0aec-4669-9679-cbc1476e0526", "name": "p1rdt6261-p1rdt6262x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c526aa31-5e92-4d33-af90-0c67bd587449"}}}}, {"uuid": "8d4d5410-3d6d-4a36-8d81-2eb1e14929e8", "name": "", "x": 38.66651499085745, "y": -122.4800586749112, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf092ec9-ecda-4216-9ac0-0bc035973515", "name": "p1rdt6262", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8d4d5410-3d6d-4a36-8d81-2eb1e14929e8"}}}}, {"uuid": "4c9a6417-dd7e-4201-97f3-4b1de459f448", "name": "", "x": 38.666918119613086, "y": -122.48091258305858, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c61df077-693e-4e67-aea6-ee60b99406d1", "name": "p1rdt6263", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c9a6417-dd7e-4201-97f3-4b1de459f448"}}}}, {"uuid": "7ca3f583-3b6e-4756-99c2-2beee9dd510f", "name": "", "x": 38.66244739498498, "y": -122.4766461808176, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e22d08f0-2afc-426a-a0c0-6b00cc1103aa", "name": "p1rdt6266", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7ca3f583-3b6e-4756-99c2-2beee9dd510f"}}}}, {"uuid": "dfcbece4-24cf-4df0-b723-98cebf605a35", "name": "", "x": 38.663631853304395, "y": -122.47754329911722, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cab917a3-5cc2-46d5-9cee-971591841f12", "name": "p1rdt6261-p1rdt6266x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dfcbece4-24cf-4df0-b723-98cebf605a35"}}}}, {"uuid": "d4d80403-25d9-41a5-9e44-5bc2e1041169", "name": "", "x": 38.66255554922429, "y": -122.47735618000138, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4a03d20d-664a-4e80-abec-a36910787829", "name": "p1rdt6264", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d4d80403-25d9-41a5-9e44-5bc2e1041169"}}}}, {"uuid": "7f90f9c9-ada7-4545-805f-74e7ff76cce2", "name": "", "x": 38.66324435870563, "y": -122.47754611470971, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9b6508ce-e51b-4173-8b54-3f3eb7a2cd71", "name": "p1rdt6266-p1rdt6267x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7f90f9c9-ada7-4545-805f-74e7ff76cce2"}}}}, {"uuid": "edabaa6d-c4da-4492-a840-5b6a75d9064f", "name": "", "x": 38.66526274271137, "y": -122.47948778772573, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a1d9cfa7-0024-4896-a263-2715086f2ad6", "name": "p1rdt6267", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "edabaa6d-c4da-4492-a840-5b6a75d9064f"}}}}, {"uuid": "3d879b6c-dee9-4e19-a2b9-c9353631ef11", "name": "", "x": 38.66146360124312, "y": -122.4739001517938, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d07105ef-1ba3-4775-aeb4-650b5ea8736e", "name": "p1rdt6266-p1rdt8174x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3d879b6c-dee9-4e19-a2b9-c9353631ef11"}}}}, {"uuid": "fa6491bf-299d-44eb-ad2d-891e877aa105", "name": "", "x": 38.75306841044715, "y": -122.36663378364803, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "79d0fee6-369b-4f95-a2d2-cd05232652e3", "name": "p1rdt181", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa6491bf-299d-44eb-ad2d-891e877aa105"}}}}, {"uuid": "c072f967-5c31-42c3-8e9b-35184b126f3f", "name": "", "x": 38.754868310420626, "y": -122.36837472635783, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "24681ab1-3904-4509-85e6-d9bb1dba4c8e", "name": "p1rdt181_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c072f967-5c31-42c3-8e9b-35184b126f3f"}}}}, {"uuid": "2ad22731-6846-4b63-baa9-765766802509", "name": "", "x": 38.771927561946114, "y": -122.36440291040475, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0d4e6a87-0313-419f-8feb-7ea3a29f59ae", "name": "p1rdt275", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2ad22731-6846-4b63-baa9-765766802509"}}}}, {"uuid": "665fada7-7a88-4136-9eab-40f5c884f0b2", "name": "", "x": 38.78773053668457, "y": -122.34702184190017, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1a85646-be2b-4b15-9c2f-cc603c7e06df", "name": "p1rdt253", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "665fada7-7a88-4136-9eab-40f5c884f0b2"}}}}, {"uuid": "b4b135e0-c9a9-4999-9448-44a19e6f2767", "name": "", "x": 38.76715093535089, "y": -122.36057334237034, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eb9e5f0f-8bcf-4019-a786-3f24334e9ae7", "name": "p1rdt68", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b4b135e0-c9a9-4999-9448-44a19e6f2767"}}}}, {"uuid": "32e939e4-5261-4ed7-9bef-2dc70b0e4447", "name": "", "x": 38.77038045634796, "y": -122.36232121374398, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8435bee2-05ea-4208-9520-809129624d70", "name": "p1rdt275-p1rdt68x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "32e939e4-5261-4ed7-9bef-2dc70b0e4447"}}}}, {"uuid": "54cceeea-9aa0-4d66-8115-b4b848862660", "name": "", "x": 38.762804233208215, "y": -122.3567217728313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e9cb7919-b8bd-46c1-a173-90a5d241c46e", "name": "p1rdt280", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "54cceeea-9aa0-4d66-8115-b4b848862660"}}}}, {"uuid": "8845fc18-33d7-47e8-a26b-2bf3b16d7ee2", "name": "", "x": 38.754224477281774, "y": -122.36483177825646, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ac745c6f-6e78-4a68-affa-649f91d3aa7c", "name": "p1rdt281", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8845fc18-33d7-47e8-a26b-2bf3b16d7ee2"}}}}, {"uuid": "cd2affdb-33a9-4f80-bda0-c84fa9ffaa09", "name": "", "x": 38.762332092473166, "y": -122.35720189679247, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4425707e-f2b0-419f-828e-a4642ee34b5a", "name": "p1rdt280-p1rdt281x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cd2affdb-33a9-4f80-bda0-c84fa9ffaa09"}}}}, {"uuid": "d1a7b63c-63eb-4950-aaa9-c61ee1ba140b", "name": "", "x": 38.72318515388558, "y": -122.41088395202819, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2fddf29e-6eef-4c60-ad8b-4580440973b3", "name": "p1rdt181-p1rdt297x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1a7b63c-63eb-4950-aaa9-c61ee1ba140b"}}}}, {"uuid": "851a2f84-14c6-409d-8071-4667378696d9", "name": "", "x": 38.726937156537616, "y": -122.40539968889463, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d87f56c0-0a3f-4a94-8f60-1ece461290d0", "name": "p1rdt181-p1rdt297x_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "851a2f84-14c6-409d-8071-4667378696d9"}}}}, {"uuid": "759e1907-5ba4-48d6-919d-b558f46832b1", "name": "", "x": 38.759945311222936, "y": -122.44222861124264, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "170a2bcb-d7ce-4617-855b-9111b84262ed", "name": "p1rdt3776", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "759e1907-5ba4-48d6-919d-b558f46832b1"}}}}, {"uuid": "7668d332-5379-4200-a145-37c5d95aa7ac", "name": "", "x": 38.75895331123435, "y": -122.44467277060775, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5f9af980-79c4-4daf-b8fc-44e02953f98b", "name": "p1rdt3777", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7668d332-5379-4200-a145-37c5d95aa7ac"}}}}, {"uuid": "02b963dd-7858-4cea-b384-6910759c8ab5", "name": "", "x": 38.7505314706947, "y": -122.41545810153862, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7eca59ac-01f1-40d7-a0ec-51f355285e01", "name": "p1rdt270", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "02b963dd-7858-4cea-b384-6910759c8ab5"}}}}, {"uuid": "0006edd5-9a24-4cdf-8952-aeacecc849f2", "name": "", "x": 38.75941275867633, "y": -122.44145409385084, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6168ebbc-8fd5-49a0-94db-887814eceaba", "name": "p1rdt270-p1rdt3776x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0006edd5-9a24-4cdf-8952-aeacecc849f2"}}}}, {"uuid": "27c267c2-ebc5-4f52-93a6-6ee6fa420984", "name": "", "x": 38.724404971590296, "y": -122.41244167570912, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e2c76250-d7ea-4da4-8008-dac1a579e974", "name": "p1rdt270-p1rdt298x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "27c267c2-ebc5-4f52-93a6-6ee6fa420984"}}}}, {"uuid": "b13b2b3e-f03d-40da-ab3d-d9146809b14f", "name": "", "x": 38.72936375125469, "y": -122.41301863676793, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ac7c613f-190c-493e-8e89-3ef48e8efdb9", "name": "p1rdt270-p1rdt298x_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b13b2b3e-f03d-40da-ab3d-d9146809b14f"}}}}, {"uuid": "f23ba844-eefe-4850-91bd-642274b7cd43", "name": "", "x": 38.72321115431449, "y": -122.41092660136522, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d32493ec-06be-48ef-959e-779c79c507a3", "name": "p1rdt297", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f23ba844-eefe-4850-91bd-642274b7cd43"}}}}, {"uuid": "f64c9648-faca-44e7-8a97-9c3c8dc95507", "name": "", "x": 38.72444619013448, "y": -122.4124539994752, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7a468f13-c61f-4c01-aa27-c75fb02030e0", "name": "p1rdt298", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f64c9648-faca-44e7-8a97-9c3c8dc95507"}}}}, {"uuid": "546b8fad-55ef-4415-a10c-2b3d67c1758c", "name": "", "x": 38.716932571899626, "y": -122.4194260124673, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "91f76b91-e00a-4a88-8ee8-ec403c2c7d96", "name": "p1rdt385", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "546b8fad-55ef-4415-a10c-2b3d67c1758c"}}}}, {"uuid": "5c83ea19-2401-4a56-b711-6b8cc4186995", "name": "", "x": 38.70723340886135, "y": -122.42474689668317, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "22179eaa-fd19-4619-8b31-52bcb36ec683", "name": "p1rdt252-p1rdt385x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5c83ea19-2401-4a56-b711-6b8cc4186995"}}}}, {"uuid": "215d5350-57f3-47a2-ad91-9221da3b8bdc", "name": "", "x": 38.7068487847659, "y": -122.42495904757907, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f9c899bc-796a-4e92-88db-6aa11f8777cb", "name": "p1rdt251-p1rdt254x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "215d5350-57f3-47a2-ad91-9221da3b8bdc"}}}}, {"uuid": "ef1d5226-a8f9-4454-a993-7cb000b03794", "name": "", "x": 38.706847489569306, "y": -122.42594987463313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ab802e3-3a0a-413c-8865-e3b3d08e44a8", "name": "p1rdt254", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef1d5226-a8f9-4454-a993-7cb000b03794"}}}}, {"uuid": "3c286a77-6cc8-436e-9fc7-c2d3036ddaba", "name": "", "x": 38.69595800578408, "y": -122.39252013725728, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8e28087b-b80e-4043-b0f0-0bc82c91f5e8", "name": "p1rdt258", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3c286a77-6cc8-436e-9fc7-c2d3036ddaba"}}}}, {"uuid": "804b2239-d5e8-48c0-9827-b37ecf5b0754", "name": "", "x": 38.697506302675386, "y": -122.39110055463347, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf660777-f77e-4d9b-afff-73a84274c270", "name": "p1rdt262", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "804b2239-d5e8-48c0-9827-b37ecf5b0754"}}}}, {"uuid": "c54df0ed-ada6-4bb9-a22a-77c5b1643b95", "name": "", "x": 38.6960521884224, "y": -122.39265347986003, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "209cebda-044a-42a3-b2f0-fe5b76b80643", "name": "p1rdt261", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c54df0ed-ada6-4bb9-a22a-77c5b1643b95"}}}}, {"uuid": "c2026069-787d-446d-98d6-de87e2aceec7", "name": "", "x": 38.696015106037905, "y": -122.39255812819005, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be0fa139-8da7-4cba-9e49-faf4a4814035", "name": "p1rdt258-p1rdt261x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c2026069-787d-446d-98d6-de87e2aceec7"}}}}, {"uuid": "4caf55e0-0b8c-407e-811a-83af58390919", "name": "", "x": 38.69712125423101, "y": -122.39909419849987, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bbe3ac37-aca0-47fd-ac5d-be390cad10ab", "name": "p1rdt261-p1rdt277x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4caf55e0-0b8c-407e-811a-83af58390919"}}}}, {"uuid": "4f2e309d-192c-4ca8-a1de-e92bdeb74d0c", "name": "", "x": 38.702132662964175, "y": -122.38784923319449, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a2b529c9-4695-42f3-a0e3-69bbb34ff285", "name": "p1rdt37-p1rdt80x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4f2e309d-192c-4ca8-a1de-e92bdeb74d0c"}}}}, {"uuid": "81d8b59a-049e-4f0c-be85-a34d084e4b44", "name": "", "x": 38.70165469665771, "y": -122.38758437608678, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9dcbfdc3-b597-4e9e-a86f-4d0ff396ba70", "name": "p1rdt37", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "81d8b59a-049e-4f0c-be85-a34d084e4b44"}}}}, {"uuid": "8f6e7c1a-1fd0-4353-ae0c-01e914a08470", "name": "", "x": 38.70226336170039, "y": -122.37889294477628, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a9c4411-f402-464c-ad25-d439b87ef768", "name": "p1rdt34", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8f6e7c1a-1fd0-4353-ae0c-01e914a08470"}}}}, {"uuid": "df30e6d5-4f96-4c9e-822f-7dc4d01fc1c6", "name": "", "x": 38.70240564817688, "y": -122.37853520540186, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "31b06630-2aae-4fe7-9e31-f911c91121cd", "name": "p1rdt77", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "df30e6d5-4f96-4c9e-822f-7dc4d01fc1c6"}}}}, {"uuid": "07e40688-ddb5-443c-82d8-7dfb1870c9b0", "name": "", "x": 38.70192539724856, "y": -122.37910641908904, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b45513a3-8e88-45e9-99d3-6d244c90c256", "name": "p1rdt38", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "07e40688-ddb5-443c-82d8-7dfb1870c9b0"}}}}, {"uuid": "26fcf062-38f3-4fc4-944a-64a938b61bab", "name": "", "x": 38.70129185446362, "y": -122.37973917584448, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "668d32be-c07a-4387-86a5-e9754af11e9c", "name": "p1rdt31-p1rdt38x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "26fcf062-38f3-4fc4-944a-64a938b61bab"}}}}, {"uuid": "ed47d79a-4bc3-482c-a4a9-cbd1e0f3ff3d", "name": "", "x": 38.701554940346995, "y": -122.37742353030349, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2b82a9a2-b1d1-44eb-a451-946643ef613d", "name": "p1rdt74-p1rdt85x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ed47d79a-4bc3-482c-a4a9-cbd1e0f3ff3d"}}}}, {"uuid": "eea93f53-2784-47ad-9645-52baa3baf1fb", "name": "", "x": 38.702210844779025, "y": -122.37749036925975, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b884fef-8b8f-4ed5-9033-b8177d1c7d70", "name": "p1rdt74", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eea93f53-2784-47ad-9645-52baa3baf1fb"}}}}, {"uuid": "147c7c3d-719e-47e9-9fbe-5d5d89ded094", "name": "", "x": 38.69878213406897, "y": -122.37500166002606, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf205ba7-ac66-4318-aeca-c75eb96cbd1e", "name": "p1rdt456", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "147c7c3d-719e-47e9-9fbe-5d5d89ded094"}}}}, {"uuid": "16e64a55-a47c-4563-9842-a45162327cac", "name": "", "x": 38.698844229551156, "y": -122.37481712432647, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cee642e7-12f0-4746-841e-d8cda6fff57e", "name": "p1rdt489", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "16e64a55-a47c-4563-9842-a45162327cac"}}}}, {"uuid": "2156d576-a0de-4c7f-8b6b-83a2796d5de4", "name": "", "x": 38.698450220223094, "y": -122.375819293565, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b092ee09-4c5e-46b5-8ec2-51f99254c220", "name": "p1rdt456-p1rdt465x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2156d576-a0de-4c7f-8b6b-83a2796d5de4"}}}}, {"uuid": "154ca468-f940-41a0-813f-c7a6390c0c78", "name": "", "x": 38.693782143657465, "y": -122.37465775612712, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "05082892-d69e-4c8f-ba19-c2a627e1c345", "name": "p1rdt46", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "154ca468-f940-41a0-813f-c7a6390c0c78"}}}}, {"uuid": "c6b93af1-6cb1-4ff7-847d-a8f8e24da09c", "name": "", "x": 38.69314320252447, "y": -122.37482430214054, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "50f3b5f3-3fb5-4fb9-b2e6-b37200af0901", "name": "p1rdt70", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c6b93af1-6cb1-4ff7-847d-a8f8e24da09c"}}}}, {"uuid": "c1697cd7-1b88-45cc-b5f6-415d8eb7a1bc", "name": "", "x": 38.69495141442872, "y": -122.3748625110079, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b61caefd-d5aa-4019-9ac0-aaf8cedc71d0", "name": "p1rdt458", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c1697cd7-1b88-45cc-b5f6-415d8eb7a1bc"}}}}, {"uuid": "886222cb-cab4-4cd2-836a-660c88e16dfa", "name": "", "x": 38.69185315698694, "y": -122.37350964662168, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2faff95d-f394-427a-9d62-75224f830c9e", "name": "p1rdt72", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "886222cb-cab4-4cd2-836a-660c88e16dfa"}}}}, {"uuid": "0ee4f148-fd6a-46ed-ad40-dd2c07a2bdea", "name": "", "x": 38.69169101529133, "y": -122.37352255937813, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a6fb1323-f697-4423-a70d-838056200402", "name": "p1rdt52", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0ee4f148-fd6a-46ed-ad40-dd2c07a2bdea"}}}}, {"uuid": "ec8d68dd-493a-4fc5-92b6-8771c3237b37", "name": "", "x": 38.693098193510316, "y": -122.37377475782415, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "137c345c-77cc-4324-bc0e-e0ba896a5f43", "name": "p1rdt49", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ec8d68dd-493a-4fc5-92b6-8771c3237b37"}}}}, {"uuid": "0990a9d9-e9d3-40e6-8e79-7a8bd3f851c3", "name": "", "x": 38.694135169317704, "y": -122.37389220491741, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1d8f5898-7d36-4e40-9980-76d11ef18adb", "name": "p1rdt56", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0990a9d9-e9d3-40e6-8e79-7a8bd3f851c3"}}}}, {"uuid": "560d2c90-f0c1-4f09-b2ab-5bdb242b8f86", "name": "", "x": 38.69445247244586, "y": -122.37424590782481, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6fa14b51-a977-4e40-8f9c-28249e576fcf", "name": "p1rdt472", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "560d2c90-f0c1-4f09-b2ab-5bdb242b8f86"}}}}, {"uuid": "5dc257f9-663e-496e-82ab-f02badf92781", "name": "", "x": 38.695584690016524, "y": -122.37575707999054, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "04fc215c-7f3e-45e1-a49c-727b0fcdae93", "name": "p1rdt458-p1rdt468x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5dc257f9-663e-496e-82ab-f02badf92781"}}}}, {"uuid": "c0ce7def-bf8a-4994-9211-1090a6708213", "name": "", "x": 38.69312267817216, "y": -122.37604335226409, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0c5d8237-0351-4eb2-83e6-13975b37bfa7", "name": "p1rdt50", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c0ce7def-bf8a-4994-9211-1090a6708213"}}}}, {"uuid": "a6e05e13-c59b-487a-a856-c53af892ec53", "name": "", "x": 38.69253761865749, "y": -122.37617492032506, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e7305e2b-0a48-4630-8b8e-c3819f1c9cd1", "name": "p1rdt53", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a6e05e13-c59b-487a-a856-c53af892ec53"}}}}, {"uuid": "d0d9e0b2-5201-4618-9538-651dea7a923c", "name": "", "x": 38.69357324297057, "y": -122.37603943809668, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4ea7e0bb-bdc5-429a-8889-2f12c94db72e", "name": "p1rdt59", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d0d9e0b2-5201-4618-9538-651dea7a923c"}}}}, {"uuid": "e2fdec26-5a5b-48a2-a148-888c835ac073", "name": "", "x": 38.69405568995833, "y": -122.37588221381021, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "577124ac-ea2b-4a60-be47-14b0f5db305e", "name": "p1rdt40", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e2fdec26-5a5b-48a2-a148-888c835ac073"}}}}, {"uuid": "49b5489f-b73f-492f-be37-43f9823f28f6", "name": "", "x": 38.69445481567878, "y": -122.37574430437743, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "12fef7fc-57f0-4494-becd-4724b84dbbcb", "name": "p1rdt457", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "49b5489f-b73f-492f-be37-43f9823f28f6"}}}}, {"uuid": "d2981dd6-bb67-4a21-b888-fa072ef2814d", "name": "", "x": 38.69524468972365, "y": -122.37577988845278, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d709af4b-1115-403b-a68d-76c63c93adf2", "name": "p1rdt474", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d2981dd6-bb67-4a21-b888-fa072ef2814d"}}}}, {"uuid": "036ca743-6e5f-4397-b298-e6da7abbbd82", "name": "", "x": 38.695656536068775, "y": -122.3757951768077, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5814195b-dd60-4a1e-9af6-b9b84fa4c0c7", "name": "p1rdt468-p1rdt474x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "036ca743-6e5f-4397-b298-e6da7abbbd82"}}}}, {"uuid": "7de12271-b8bc-4949-9775-db2f3d0fa8b9", "name": "", "x": 38.69416819650434, "y": -122.37332846825741, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f9397c58-45a1-4ec3-bd84-b4cd5b52dc80", "name": "p1rdt65", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7de12271-b8bc-4949-9775-db2f3d0fa8b9"}}}}, {"uuid": "f574c707-7785-4ef9-9cf6-4f890606558b", "name": "", "x": 38.69364252102314, "y": -122.37276961025155, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ab2b6727-4d87-4b00-bd49-ba7a6b1b9ce6", "name": "p1rdt63", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f574c707-7785-4ef9-9cf6-4f890606558b"}}}}, {"uuid": "ddcf1e4b-2864-4c58-9602-0c22fa480875", "name": "", "x": 38.69429429294349, "y": -122.37331586905341, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4ae86125-88c3-44fb-9fe9-1a5d820606f6", "name": "p1rdt467", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ddcf1e4b-2864-4c58-9602-0c22fa480875"}}}}, {"uuid": "df901f95-bfa5-4f1a-be8d-56be09dc1b3a", "name": "", "x": 38.69469140583874, "y": -122.37342739439052, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48179f57-b0b9-491b-b654-81583768923a", "name": "p1rdt469", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "df901f95-bfa5-4f1a-be8d-56be09dc1b3a"}}}}, {"uuid": "956e346e-1e34-4cec-b6f1-259a87f18ad5", "name": "", "x": 38.69542702599285, "y": -122.37386149152691, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a634585d-0c70-428e-a3b2-1ec4717d7878", "name": "p1rdt464", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "956e346e-1e34-4cec-b6f1-259a87f18ad5"}}}}, {"uuid": "09d2e6ee-2f60-4e01-83a5-962fd176bb64", "name": "", "x": 38.69557377117983, "y": -122.37396893690091, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2e5c3d02-1cd2-45e4-90d3-10b135c65f13", "name": "p1rdt480", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "09d2e6ee-2f60-4e01-83a5-962fd176bb64"}}}}, {"uuid": "5a7937d8-a3eb-45f2-b178-6c3eead7e7cc", "name": "", "x": 38.69642974090264, "y": -122.37431272204606, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "76880999-6f79-4fc6-9367-1c419eee26d5", "name": "p1rdt473", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5a7937d8-a3eb-45f2-b178-6c3eead7e7cc"}}}}, {"uuid": "fea57a38-f4cb-464a-aeee-8c88416598f1", "name": "", "x": 38.69676892757635, "y": -122.37432921866969, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d1bb6f93-7aed-47d7-99db-7c17352a42b8", "name": "p1rdt453", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fea57a38-f4cb-464a-aeee-8c88416598f1"}}}}, {"uuid": "7de38676-e68c-41bd-b881-6545360d00a9", "name": "", "x": 38.697042200822686, "y": -122.37424988896967, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d51e6f65-c45c-4f10-a17f-6ef684a0a06c", "name": "p1rdt452", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7de38676-e68c-41bd-b881-6545360d00a9"}}}}, {"uuid": "d1220ca0-5321-4d82-a08a-3738153e2860", "name": "", "x": 38.69788387901549, "y": -122.3749210284041, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b20fa59a-8573-461a-9c4a-0d47e40d2601", "name": "p1rdt466", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1220ca0-5321-4d82-a08a-3738153e2860"}}}}, {"uuid": "c75db6cf-545e-48dc-8ac1-330cef2f7643", "name": "", "x": 38.69827011722288, "y": -122.37584385822461, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "64ba6716-89f9-49a4-9793-ba80ae41bcd0", "name": "p1rdt466-p1rdt478x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c75db6cf-545e-48dc-8ac1-330cef2f7643"}}}}, {"uuid": "715de1e8-65e3-4ad3-9996-d73649cb2471", "name": "", "x": 38.701722794560474, "y": -122.37384904824599, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "12d5c579-0570-44db-a751-8eeb92355af9", "name": "p1rdt459", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "715de1e8-65e3-4ad3-9996-d73649cb2471"}}}}, {"uuid": "a4a0e6c6-1a05-444c-8d95-22a456abb8b6", "name": "", "x": 38.701153728978355, "y": -122.37360100904912, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eed7e6a8-2b4a-4a54-b69a-e3e1a0614213", "name": "p1rdt471", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a4a0e6c6-1a05-444c-8d95-22a456abb8b6"}}}}, {"uuid": "9c8b7067-51d1-4537-b1ae-3e54b168100a", "name": "", "x": 38.702243046289325, "y": -122.3733960017453, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fcfdc5bf-1c87-42e2-8b35-1f7125d3b5ed", "name": "p1rdt462", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9c8b7067-51d1-4537-b1ae-3e54b168100a"}}}}, {"uuid": "f13eb1dc-c712-49aa-af69-41037bc6049a", "name": "", "x": 38.702902444369066, "y": -122.37348707489292, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dfb0d992-ab18-4f73-933e-a01ce73ef3b2", "name": "p1rdt487", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f13eb1dc-c712-49aa-af69-41037bc6049a"}}}}, {"uuid": "76e35c9a-9560-4eeb-8df3-09560a9c278e", "name": "", "x": 38.72548231736972, "y": -122.31263452007998, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4774ed1a-85ec-4ca0-8e9a-3b232588fb0c", "name": "p1rdt16790", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "76e35c9a-9560-4eeb-8df3-09560a9c278e"}}}}, {"uuid": "0265a43f-a1e0-4db0-b8c6-5963dd5ac674", "name": "", "x": 38.7248434734621, "y": -122.31174862017714, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d4bc644c-9875-4846-8b0f-dfa0568de623", "name": "p1rdt16787", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0265a43f-a1e0-4db0-b8c6-5963dd5ac674"}}}}, {"uuid": "20c89e0d-0eeb-4562-be97-b9842e309720", "name": "", "x": 38.741935598212194, "y": -122.27647050486847, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d29266e8-ce67-45bf-93d9-710d4684ce0b", "name": "p1rdt16790-p1rdt16911x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "20c89e0d-0eeb-4562-be97-b9842e309720"}}}}, {"uuid": "7e5d3205-621f-494a-ab6d-fad769918f9e", "name": "", "x": 38.743604391211804, "y": -122.2733738127215, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "725fbd98-74ba-4143-8947-da9fdc209889", "name": "p1rdt16911", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7e5d3205-621f-494a-ab6d-fad769918f9e"}}}}, {"uuid": "42ca79ed-f62f-4ac0-9102-c9659c386bdb", "name": "", "x": 38.70287643040543, "y": -122.37344445127026, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d53ff9fd-2b16-4026-88fa-2c112d4949c5", "name": "p1rdt16790-p1rdt487xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "42ca79ed-f62f-4ac0-9102-c9659c386bdb"}}}}, {"uuid": "c0e3a7e7-c16f-4b7d-a18a-6aab1ae6d4da", "name": "", "x": 38.703325006090246, "y": -122.37234754500905, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a1b5b099-df99-4729-a26d-f0882e93136f", "name": "p1rdt16790-p1rdt487x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c0e3a7e7-c16f-4b7d-a18a-6aab1ae6d4da"}}}}, {"uuid": "21750166-4903-4b4c-ba19-0e6b7f9489e0", "name": "", "x": 38.70318635641241, "y": -122.37390883465856, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b57b8e2b-62c2-49a0-801d-02cab8092ebd", "name": "p1rdt484", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "21750166-4903-4b4c-ba19-0e6b7f9489e0"}}}}, {"uuid": "2b9e9c66-5072-4da7-8003-57c1fa927b48", "name": "", "x": 38.70352176107739, "y": -122.37490290192596, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bd2f4b00-6e8b-4faa-a760-7c28f8d36a36", "name": "p1rdt486", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2b9e9c66-5072-4da7-8003-57c1fa927b48"}}}}, {"uuid": "d8957db5-cbe5-4d00-85fe-945d701e8053", "name": "", "x": 38.7035351825914, "y": -122.37510184014613, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "10c2463d-8563-4737-aa7d-e1195c0af9f6", "name": "p1rdt482", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d8957db5-cbe5-4d00-85fe-945d701e8053"}}}}, {"uuid": "d3f45a56-1323-4e5a-bb45-4854c58e77f0", "name": "", "x": 38.70367069880678, "y": -122.37631203298449, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e4064b6c-40b4-418b-95ab-4f9bb0363b14", "name": "p1rdt482-p1rdt485x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d3f45a56-1323-4e5a-bb45-4854c58e77f0"}}}}, {"uuid": "95d9dc99-1cb5-461e-a945-a57274c2eebd", "name": "", "x": 38.70062992258327, "y": -122.37444862489892, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d1eb09d-dff4-4fa3-b96f-ef59b63d6128", "name": "p1rdt477", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "95d9dc99-1cb5-461e-a945-a57274c2eebd"}}}}, {"uuid": "0a21d1b9-6ab1-49d5-a780-884c93792a4d", "name": "", "x": 38.70017599315202, "y": -122.374449032179, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5421facb-0713-404c-97e9-56669fc762b3", "name": "p1rdt476", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a21d1b9-6ab1-49d5-a780-884c93792a4d"}}}}, {"uuid": "5d69f592-01fb-4253-8b5f-8e5d349e1d8a", "name": "", "x": 38.7012326324604, "y": -122.37424787273476, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "85acd1fb-6da3-432a-9508-855ca991641b", "name": "p1rdt479", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5d69f592-01fb-4253-8b5f-8e5d349e1d8a"}}}}, {"uuid": "5cef3667-c445-4b39-bb1f-8c1ab800b88d", "name": "", "x": 38.70153006625403, "y": -122.37425678080724, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "82459f47-0c6f-4173-8c35-5a9fe5db9713", "name": "p1rdt454", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5cef3667-c445-4b39-bb1f-8c1ab800b88d"}}}}, {"uuid": "c3d04bfb-0722-4c14-b3e2-2a08a319c69e", "name": "", "x": 38.701876062215334, "y": -122.37492077650421, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "183de04a-a665-4112-a912-1df68b61d164", "name": "p1rdt455", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c3d04bfb-0722-4c14-b3e2-2a08a319c69e"}}}}, {"uuid": "98278fc0-28a5-42e6-bb31-86f9b808baa4", "name": "", "x": 38.70221801359906, "y": -122.37545476381091, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "59b616e5-76b8-406c-843f-5c71398af81b", "name": "p1rdt460", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "98278fc0-28a5-42e6-bb31-86f9b808baa4"}}}}, {"uuid": "dea738bd-0034-4241-af54-c69d1a1de21a", "name": "", "x": 38.702478034778096, "y": -122.37458202766794, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "86178159-ccd7-45a3-b711-ac237321d52a", "name": "p1rdt470", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dea738bd-0034-4241-af54-c69d1a1de21a"}}}}, {"uuid": "17dc86f4-06a4-4f36-a0c0-053ed5d6918b", "name": "", "x": 38.702879570888186, "y": -122.37552155877664, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "69b5d686-dae0-44c5-a261-f1a73bcb168e", "name": "p1rdt483", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "17dc86f4-06a4-4f36-a0c0-053ed5d6918b"}}}}, {"uuid": "f3209dfb-0d4c-454f-b128-6d905623f51c", "name": "", "x": 38.703660453271056, "y": -122.37621331185325, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d899b807-b194-4f65-bad5-a39e8bc61906", "name": "p1rdt483-p1rdt485x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f3209dfb-0d4c-454f-b128-6d905623f51c"}}}}, {"uuid": "3cdd14db-f66c-40e6-a154-04d71f132931", "name": "", "x": 38.696234466020165, "y": -122.4029175301028, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "232adbbb-2715-44be-8db5-ee062ebf4e46", "name": "p1rdt279-p1rdt89x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3cdd14db-f66c-40e6-a154-04d71f132931"}}}}, {"uuid": "d36ac9a4-d6a8-48ba-a00f-294724d9c50b", "name": "", "x": 38.6936090734191, "y": -122.40307695118932, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "416118a8-65b7-4d9e-90a2-454f065bfddb", "name": "p1rdt279-p1rdt89xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d36ac9a4-d6a8-48ba-a00f-294724d9c50b"}}}}, {"uuid": "5a37f945-3b6c-4993-8b09-bd86f15e9ca8", "name": "", "x": 38.691921020060555, "y": -122.4037273791967, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ac4ad276-90cb-48c0-bfd0-1f2aa0233ce2", "name": "p1rdt89", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5a37f945-3b6c-4993-8b09-bd86f15e9ca8"}}}}, {"uuid": "1d7465a0-15cf-41d5-961d-c03eaf8bcc3c", "name": "", "x": 38.71273376728585, "y": -122.26236860525948, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d50d3e76-470b-47c2-ada2-da944962b322", "name": "p1rdt16427", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d7465a0-15cf-41d5-961d-c03eaf8bcc3c"}}}}, {"uuid": "832689e9-558f-4425-9e83-1b5db67ee44f", "name": "", "x": 38.713290303421466, "y": -122.26149228450026, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "18e3da78-83fc-4b8e-9d45-41adb9b753ad", "name": "p1rdt16424", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "832689e9-558f-4425-9e83-1b5db67ee44f"}}}}, {"uuid": "7fec0620-591f-4608-b812-80cf87d91f9d", "name": "", "x": 38.69570787792313, "y": -122.29851285731566, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8e35a4f7-19c1-4f59-9adc-b267f6088264", "name": "p1rdt16847", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7fec0620-591f-4608-b812-80cf87d91f9d"}}}}, {"uuid": "6704537b-9d53-40b6-b9e8-e67e3d651524", "name": "", "x": 38.71191996461427, "y": -122.26381070914681, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a6382a2-8c21-4cb4-a39b-3f1ac62cc705", "name": "p1rdt16427-p1rdt16847x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6704537b-9d53-40b6-b9e8-e67e3d651524"}}}}, {"uuid": "cc64522b-669a-4319-93fb-4f32f3956d1b", "name": "", "x": 38.68960809733261, "y": -122.30930023811142, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "61d5dee2-30f8-434d-8c03-76bccff72549", "name": "p1rdt16404", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc64522b-669a-4319-93fb-4f32f3956d1b"}}}}, {"uuid": "27628ce8-d3dd-4b33-8235-963ca36f778a", "name": "", "x": 38.69038163570117, "y": -122.31517993828531, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c5b51836-1807-4fab-b877-94a62021569f", "name": "p1rdt16394", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "27628ce8-d3dd-4b33-8235-963ca36f778a"}}}}, {"uuid": "420ccfac-7dbd-4510-83b6-2bea0e849955", "name": "", "x": 38.684262624044464, "y": -122.31767924836156, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b5a9e0f5-d824-4a76-a4f0-88aab072280e", "name": "p1rdt16603", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "420ccfac-7dbd-4510-83b6-2bea0e849955"}}}}, {"uuid": "88bd7eea-2f21-4a0d-879d-c3a70ed66def", "name": "", "x": 38.68314419705685, "y": -122.31905803173453, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "98a946e8-3c8a-49ec-be8a-5610c7fc596c", "name": "p1rdt16604", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "88bd7eea-2f21-4a0d-879d-c3a70ed66def"}}}}, {"uuid": "4fd2ad5d-d4e0-480c-a014-3cc3aa2fa98d", "name": "", "x": 38.68864067156756, "y": -122.34840259338564, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ef71bd7-4c82-4296-a6ac-64516ffe96c5", "name": "p1rdt16604-p1rdt257x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4fd2ad5d-d4e0-480c-a014-3cc3aa2fa98d"}}}}, {"uuid": "f00cd8ba-b7f8-491a-b665-015a9277eadf", "name": "", "x": 38.68800685251441, "y": -122.34473682420163, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "282d8a89-8b14-476b-9e55-b310d8b9396d", "name": "p1rdt16604-p1rdt257x_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f00cd8ba-b7f8-491a-b665-015a9277eadf"}}}}, {"uuid": "1e961363-685e-4320-a9c9-c6a11ef0dc32", "name": "", "x": 38.68510682934324, "y": -122.35589682226349, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dcb27aab-e828-41a6-ad98-d197897a1a69", "name": "p1rdt209", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1e961363-685e-4320-a9c9-c6a11ef0dc32"}}}}, {"uuid": "a0cc6f33-f3de-4070-97bb-48c0aa09dfbf", "name": "", "x": 38.688681896745614, "y": -122.34841487443683, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3fb307f7-3690-4931-999a-4daab4d8c9e5", "name": "p1rdt257", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a0cc6f33-f3de-4070-97bb-48c0aa09dfbf"}}}}, {"uuid": "c26732ea-f986-41bc-95b2-b21b77a33f93", "name": "", "x": 38.68463781682152, "y": -122.35798033063733, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5d782d5e-3960-415c-9e33-6742777a5a0a", "name": "p1rdt210", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c26732ea-f986-41bc-95b2-b21b77a33f93"}}}}, {"uuid": "49ded750-7593-4589-9e1f-5c12c16bb481", "name": "", "x": 38.683540995258845, "y": -122.35679446809597, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b9401940-26a4-40f3-9b9a-5231a5c4e171", "name": "p1rdt211", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "49ded750-7593-4589-9e1f-5c12c16bb481"}}}}, {"uuid": "365a5752-e72f-4dc2-b314-1e000a8741e4", "name": "", "x": 38.68281023348963, "y": -122.35409734055312, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b89bfea1-97cd-41f7-af59-9602a3fc6c06", "name": "p1rdt278", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "365a5752-e72f-4dc2-b314-1e000a8741e4"}}}}, {"uuid": "8d37cf05-96a3-4d8e-bc5c-a40817f491c0", "name": "", "x": 38.68941008309863, "y": -122.37010832848992, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d1be5e34-ad5e-4c78-8067-8e0194c661a4", "name": "p1rdt210-p1rdt44x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8d37cf05-96a3-4d8e-bc5c-a40817f491c0"}}}}, {"uuid": "d48bab44-c136-4b4b-b5ef-2edb555ca1aa", "name": "", "x": 38.689335231948924, "y": -122.37012765218032, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f0b5743e-c3fd-49c7-879e-9be7d00c480f", "name": "p1rdt259-p1rdt44x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d48bab44-c136-4b4b-b5ef-2edb555ca1aa"}}}}, {"uuid": "d3241610-de63-4356-9931-09d85e05faa4", "name": "", "x": 38.68475989424937, "y": -122.36996130497471, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33a0a070-9cce-4a82-bd22-24a65f02ef97", "name": "p1rdt259", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d3241610-de63-4356-9931-09d85e05faa4"}}}}, {"uuid": "6861d9ef-ae9d-4bcd-b45d-e3cea1fee6da", "name": "", "x": 38.69119253254578, "y": -122.3723691075126, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7728581d-66fc-4e7e-b2b0-85fa02c90523", "name": "p1rdt43", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6861d9ef-ae9d-4bcd-b45d-e3cea1fee6da"}}}}, {"uuid": "99953f4d-982e-4c24-b529-2f7f64d2139a", "name": "", "x": 38.69217068541305, "y": -122.3732804512017, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1ea0531d-530c-4088-86a1-3de96a8938ea", "name": "p1rdt47", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "99953f4d-982e-4c24-b529-2f7f64d2139a"}}}}, {"uuid": "b9bda6ac-99c6-477c-960d-36334462a180", "name": "", "x": 38.692501666976284, "y": -122.37176768850954, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1667a8c6-aeb4-4f22-97b8-62ffefcc12a4", "name": "p1rdt48", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b9bda6ac-99c6-477c-960d-36334462a180"}}}}, {"uuid": "6fa6d556-40b3-48e9-9dd4-53c85726e76f", "name": "", "x": 38.69243929619441, "y": -122.37127733774665, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4f5cef5c-bcaf-4cd9-afbb-a18bd14dfcd4", "name": "p1rdt51", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6fa6d556-40b3-48e9-9dd4-53c85726e76f"}}}}, {"uuid": "a02913b0-c109-4683-9794-a5abb4af1cd6", "name": "", "x": 38.69084016635201, "y": -122.37219971004839, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d99e903-3536-4a73-b0d5-ca11f5af6e32", "name": "p1rdt60", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a02913b0-c109-4683-9794-a5abb4af1cd6"}}}}, {"uuid": "b593050b-e132-4544-810f-e168f484e82a", "name": "", "x": 38.69044403976456, "y": -122.37227216228393, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a4ccf80-2611-4089-9353-439809aa7854", "name": "p1rdt58", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b593050b-e132-4544-810f-e168f484e82a"}}}}, {"uuid": "faf45571-2233-4e14-8dbd-a4cb9bb93984", "name": "", "x": 38.690014841841176, "y": -122.3723741213489, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7238345a-1fc7-4f3f-bc8b-88cf7582c75c", "name": "p1rdt58-p1rdt69x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "faf45571-2233-4e14-8dbd-a4cb9bb93984"}}}}, {"uuid": "cb7173bb-4199-4353-9284-a0bc9e239ac0", "name": "", "x": 38.691521445820555, "y": -122.37639464686723, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bcea1fd6-3c51-48af-8528-d3d7bc8e4f01", "name": "p1rdt71", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb7173bb-4199-4353-9284-a0bc9e239ac0"}}}}, {"uuid": "6063cb06-32cd-4338-85e5-260df69cd2de", "name": "", "x": 38.69124250818054, "y": -122.37559619861726, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "744725a8-af2a-47cf-948f-9d453a932e32", "name": "p1rdt61", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6063cb06-32cd-4338-85e5-260df69cd2de"}}}}, {"uuid": "ddcdbfed-3171-4fa1-b47a-20f5a01c95ab", "name": "", "x": 38.69156944308755, "y": -122.37634466226288, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eab6b8c5-ee7a-4779-b5eb-5205dbe5253c", "name": "p1rdt150-p1rdt71x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ddcdbfed-3171-4fa1-b47a-20f5a01c95ab"}}}}, {"uuid": "91db4e45-8d24-4b88-9548-edc1fcce5953", "name": "", "x": 38.69156345018649, "y": -122.37716473257039, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf5b238a-832f-4f45-8a36-2248549e1723", "name": "p1rdt150-p1rdt71xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "91db4e45-8d24-4b88-9548-edc1fcce5953"}}}}, {"uuid": "ef35acf6-032c-4963-a01f-2230eacca63a", "name": "", "x": 38.686995650033, "y": -122.45197514226767, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0f2a0358-b10d-4b62-8f8d-9a5054fae87d", "name": "p1rdt376", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef35acf6-032c-4963-a01f-2230eacca63a"}}}}, {"uuid": "8f3f93e7-1578-47b2-86b9-794346f706ac", "name": "", "x": 38.68750853010239, "y": -122.45098420292979, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d425a00d-c0e9-465d-9d9b-af4d64708fba", "name": "p1rdt374", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8f3f93e7-1578-47b2-86b9-794346f706ac"}}}}, {"uuid": "19d36e6c-2460-47b8-9e33-b4dcbcb80539", "name": "", "x": 38.68515597552901, "y": -122.45198911454673, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0de112ae-d04a-4673-98af-0699e4890429", "name": "p1rdt335-p1rdt376x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "19d36e6c-2460-47b8-9e33-b4dcbcb80539"}}}}, {"uuid": "af233a4c-7d45-41d9-a62c-72de519562f2", "name": "", "x": 38.67357675550989, "y": -122.4699912914106, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "101c6236-a474-45c8-b065-f5fa045b1107", "name": "p1rdt415", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "af233a4c-7d45-41d9-a62c-72de519562f2"}}}}, {"uuid": "9f19600a-edcd-46ba-ae35-6e1056793679", "name": "", "x": 38.67350163747049, "y": -122.4708045160677, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "71fa675e-bc20-46f7-b6f1-c88962f9f3cb", "name": "p1rdt417", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9f19600a-edcd-46ba-ae35-6e1056793679"}}}}, {"uuid": "bea72cbb-7842-4b45-817f-7fb1e09441f5", "name": "", "x": 38.67293062003175, "y": -122.46738711812904, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "19116f3c-29ae-4819-ba72-dd0f8afa5078", "name": "p1rdt415-p1rdt419x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bea72cbb-7842-4b45-817f-7fb1e09441f5"}}}}, {"uuid": "8d8841bf-aa27-4b28-ac54-de67f23e7732", "name": "", "x": 38.665494529835904, "y": -122.46043005782059, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9100fbd6-863e-48b2-94ed-aca1ef0947bd", "name": "p1rdt5098", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8d8841bf-aa27-4b28-ac54-de67f23e7732"}}}}, {"uuid": "5813a119-def8-4d45-b4bb-5d832ab51878", "name": "", "x": 38.66895816218114, "y": -122.45865330515163, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5258d4de-be4c-478d-b752-7f4efb0af0a5", "name": "p1rdt180", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5813a119-def8-4d45-b4bb-5d832ab51878"}}}}, {"uuid": "8c5463e5-55d2-48d9-b10f-67b2ccace9cd", "name": "", "x": 38.66514031344027, "y": -122.44753960527862, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9f273a36-c30d-4962-81f4-26f8d20e1cf4", "name": "p1rdt6584", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8c5463e5-55d2-48d9-b10f-67b2ccace9cd"}}}}, {"uuid": "71bd4c9c-02a9-484c-aca4-ac5ffddf68dd", "name": "", "x": 38.66464311110499, "y": -122.44791919098567, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e257530-1fe2-410b-83a1-57789e6ddeda", "name": "p1rdt6578", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "71bd4c9c-02a9-484c-aca4-ac5ffddf68dd"}}}}, {"uuid": "6a0a739a-8c43-452d-ac2c-72a7a7e2d4d6", "name": "", "x": 38.66574098458345, "y": -122.44687980665202, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1648fe3-a7f9-47aa-b168-d2b56cf220e7", "name": "p1rdt6588", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a0a739a-8c43-452d-ac2c-72a7a7e2d4d6"}}}}, {"uuid": "c3aa5e75-c547-4302-a29e-0a307e7e49c0", "name": "", "x": 38.66451724050103, "y": -122.44667705028046, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1d0a85a-62dc-46d2-bae1-d43d07743a34", "name": "p1rdt6591", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c3aa5e75-c547-4302-a29e-0a307e7e49c0"}}}}, {"uuid": "9e340273-38a6-48fe-869c-873f661a3243", "name": "", "x": 38.664682198133455, "y": -122.446168239027, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5291ea2b-6990-407b-b8d4-d6868bf37310", "name": "p1rdt6590", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9e340273-38a6-48fe-869c-873f661a3243"}}}}, {"uuid": "48f38dca-aa76-4927-9b84-65ffec914a19", "name": "", "x": 38.666084365577824, "y": -122.44838916371525, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d77add8e-ba22-4b44-9c0b-0bddc251a573", "name": "p1rdt6587", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "48f38dca-aa76-4927-9b84-65ffec914a19"}}}}, {"uuid": "70b56e2a-5e1c-4c12-a230-51d8f4fdc039", "name": "", "x": 38.6658846543716, "y": -122.44807809992015, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b918e583-d163-4136-aaf8-62085c7b0c17", "name": "p1rdt6584-p1rdt6587x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "70b56e2a-5e1c-4c12-a230-51d8f4fdc039"}}}}, {"uuid": "42b72520-be1d-4c12-a534-0a09bcbf8c0b", "name": "", "x": 38.66666084985903, "y": -122.45155897573034, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "68298e92-fca3-44e9-9271-f79be47c9c63", "name": "p1rdt6580", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "42b72520-be1d-4c12-a534-0a09bcbf8c0b"}}}}, {"uuid": "9700ef27-7399-42c3-a41c-ba76f3a5ba0d", "name": "", "x": 38.66481336487895, "y": -122.46776680294279, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cb3d775d-8d92-498b-989c-387278ec8e9e", "name": "p1rdt5098-p1rdt8169x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9700ef27-7399-42c3-a41c-ba76f3a5ba0d"}}}}, {"uuid": "f5375e9b-fd09-4d67-abb9-558b3cc8346c", "name": "", "x": 38.66954985597873, "y": -122.47289306798201, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16b7f1e9-3405-4c5f-96c7-d5c08d791907", "name": "p1rdt418", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5375e9b-fd09-4d67-abb9-558b3cc8346c"}}}}, {"uuid": "0dd337d1-0ca4-48d8-8854-be2ef5efcfc5", "name": "", "x": 38.669198863842276, "y": -122.47439167095719, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3034e62-dd19-4ecb-bb39-6d0566e3a2ef", "name": "p1rdt414", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0dd337d1-0ca4-48d8-8854-be2ef5efcfc5"}}}}, {"uuid": "451ee1d6-69bb-4c5a-add8-b26af72700e1", "name": "", "x": 38.669612414212985, "y": -122.47279835298632, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ba78164d-d6ae-413b-8d24-067d8d38b28f", "name": "p1rdt416-p1rdt418x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "451ee1d6-69bb-4c5a-add8-b26af72700e1"}}}}, {"uuid": "13226904-e2e9-4814-b434-26821b104bc7", "name": "", "x": 38.671409309606254, "y": -122.47045206876079, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d16d5f5e-a376-4e39-a845-d2cde8800da3", "name": "p1rdt416", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "13226904-e2e9-4814-b434-26821b104bc7"}}}}, {"uuid": "48de8757-efa8-483a-8c9c-5c4f6109a371", "name": "", "x": 38.666461847991535, "y": -122.47096331177207, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1e3d41a7-06a4-460b-aa6c-3a60c8d2de10", "name": "p1rdt8201", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "48de8757-efa8-483a-8c9c-5c4f6109a371"}}}}, {"uuid": "ab0cc721-fe40-47c1-af8d-c996d017fdd8", "name": "", "x": 38.66526928202583, "y": -122.47027798516622, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "63928702-c44a-4e83-9cca-7ce77bdbd2b3", "name": "p1rdt8180-p1rdt8201x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ab0cc721-fe40-47c1-af8d-c996d017fdd8"}}}}, {"uuid": "22822696-ace4-4b6e-9db9-cf01859dd5b7", "name": "", "x": 38.658100245225164, "y": -122.48194171749711, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "246ad62e-5a10-4031-94e7-1732f58f1da9", "name": "p1rdt9055", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "22822696-ace4-4b6e-9db9-cf01859dd5b7"}}}}, {"uuid": "42866221-5545-4352-b430-fcf9cba1b4d0", "name": "", "x": 38.658393900938755, "y": -122.48112128391094, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cd9ea283-dbd2-4f38-b298-86a191c99bd2", "name": "p1rdt6265-p1rdt9055x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "42866221-5545-4352-b430-fcf9cba1b4d0"}}}}, {"uuid": "e03f9558-f8a9-4c77-88dd-fd9becc4fa78", "name": "", "x": 38.66056852061021, "y": -122.48035453306898, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2d316c13-77c1-4412-baf9-801f7e5ae407", "name": "p1rdt6265", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e03f9558-f8a9-4c77-88dd-fd9becc4fa78"}}}}, {"uuid": "60ff6017-72bc-4e90-890f-a061fd92703b", "name": "", "x": 38.65517194896592, "y": -122.48092661777345, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "30adfcd5-405b-47ea-be54-55c5a47c835f", "name": "p1rdt5560-p1rdt9055x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "60ff6017-72bc-4e90-890f-a061fd92703b"}}}}, {"uuid": "486eb953-e908-4a2e-a027-ef91dd99a6d8", "name": "", "x": 38.65725844991055, "y": -122.4811294760667, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "708f65d6-b869-4d26-930d-0e669caf4ffb", "name": "p1rdt5560-p1rdt9055xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "486eb953-e908-4a2e-a027-ef91dd99a6d8"}}}}, {"uuid": "28380f22-c0fa-475d-b399-b1cf74e2d018", "name": "", "x": 38.65230276217263, "y": -122.47461858577147, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d2ea25e-3d48-4b1d-9e52-768752de2e09", "name": "p1rdt7737", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "28380f22-c0fa-475d-b399-b1cf74e2d018"}}}}, {"uuid": "8f2f7c97-e09b-479b-837d-464111202a96", "name": "", "x": 38.65261575836355, "y": -122.4740602281008, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d142315b-a247-4a4d-a178-73e3c150a188", "name": "p1rdt7753", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8f2f7c97-e09b-479b-837d-464111202a96"}}}}, {"uuid": "5e5b7087-e9b0-48be-b147-19fd7f3264c1", "name": "", "x": 38.65184325416811, "y": -122.47515027973938, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4413ca7f-fdd1-484e-a0ba-3ff2447ebfef", "name": "p1rdt7791", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5e5b7087-e9b0-48be-b147-19fd7f3264c1"}}}}, {"uuid": "5d9e1eac-53fe-4947-b515-8daa7226ff69", "name": "", "x": 38.65207704845808, "y": -122.47515639717327, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0946738d-95de-4ad6-9d56-c043cb64c0e4", "name": "p1rdt7737-p1rdt7791x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5d9e1eac-53fe-4947-b515-8daa7226ff69"}}}}, {"uuid": "2826c794-b792-4ddc-8cc3-299a0c520ed3", "name": "", "x": 38.650951110512295, "y": -122.47644062493562, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "02351140-e632-49e2-83e4-7e5bc1c8856a", "name": "p1rdt7286", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2826c794-b792-4ddc-8cc3-299a0c520ed3"}}}}, {"uuid": "bd1fc43e-5a7b-4ff3-a94b-13041d21829c", "name": "", "x": 38.650648984972726, "y": -122.4768636646543, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8f8375b7-7bdd-409c-9fa1-5c13bd233364", "name": "p1rdt7289", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bd1fc43e-5a7b-4ff3-a94b-13041d21829c"}}}}, {"uuid": "1021a436-70ff-46d2-a2b1-36a6647e3118", "name": "", "x": 38.64944561704761, "y": -122.4757921819993, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4afa9bec-d8da-4449-ab96-9f875bae3c33", "name": "p1rdt7293", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1021a436-70ff-46d2-a2b1-36a6647e3118"}}}}, {"uuid": "69c7c6c7-1a98-4695-8108-a198c0b20ae5", "name": "", "x": 38.65290986333587, "y": -122.48317621935037, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0c83b6ee-20fc-4ca0-a778-44735283afd5", "name": "p1rdt5568", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "69c7c6c7-1a98-4695-8108-a198c0b20ae5"}}}}, {"uuid": "4426b99d-b785-4e5c-8972-5c972cdc1537", "name": "", "x": 38.653647469597004, "y": -122.48368389304464, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c8aa126c-9b2b-4ae0-a4fc-36d4201762a0", "name": "p1rdt5551-p1rdt5568xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4426b99d-b785-4e5c-8972-5c972cdc1537"}}}}, {"uuid": "ead5b8ed-3484-430c-a8ae-dc48d05070f0", "name": "", "x": 38.653032242675096, "y": -122.48324009208464, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "65eb08cf-6350-410a-88c2-3b318d3a262a", "name": "p1rdt5551-p1rdt5568xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ead5b8ed-3484-430c-a8ae-dc48d05070f0"}}}}, {"uuid": "3e1daa0b-ddcc-4ad5-9f93-673e981a9174", "name": "", "x": 38.652900682241246, "y": -122.48322892310364, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "64aba8d5-1dd3-4741-a8ba-26801e275ba8", "name": "p1rdt5551-p1rdt5568xxxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e1daa0b-ddcc-4ad5-9f93-673e981a9174"}}}}, {"uuid": "231d6b41-e4d1-42bc-9618-d294db1cb3a1", "name": "", "x": 38.65348179379366, "y": -122.4842621130032, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0c49b671-0b2b-43c9-bcb5-21c7b7e716ce", "name": "p1rdt5548-p1rdt5577xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "231d6b41-e4d1-42bc-9618-d294db1cb3a1"}}}}, {"uuid": "ea0b67e7-491e-44da-a05f-d51bc1dc6c07", "name": "", "x": 38.652151086540165, "y": -122.48369686652708, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fead5749-3ba7-4ead-a604-e8adbd18f8c2", "name": "p1rdt5548-p1rdt5577xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea0b67e7-491e-44da-a05f-d51bc1dc6c07"}}}}, {"uuid": "202ca4fc-f7c0-4c03-85d6-93e58cf5c199", "name": "", "x": 38.67222953111598, "y": -122.47625831645591, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c51ccb17-eed6-4ce0-b839-e7b26001fe3e", "name": "p1rdt304", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "202ca4fc-f7c0-4c03-85d6-93e58cf5c199"}}}}, {"uuid": "cf4d842f-4898-4504-99b0-7952f53b6158", "name": "", "x": 38.67878840609695, "y": -122.47525103045935, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "08e378d4-4ca6-4c9e-93fa-36ff87a3cf0f", "name": "p1rdt182", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cf4d842f-4898-4504-99b0-7952f53b6158"}}}}, {"uuid": "78af3e58-f400-406c-bd8e-efa3077f8637", "name": "", "x": 38.67077336251232, "y": -122.47582856074445, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7b936973-54dc-41e7-a413-8932c31f0793", "name": "p1rdt305", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "78af3e58-f400-406c-bd8e-efa3077f8637"}}}}, {"uuid": "8019fa58-ddff-4d58-9d54-6ba68f47b6af", "name": "", "x": 38.670527094141356, "y": -122.4798175179331, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9672c49b-8316-4907-b204-7505483210b0", "name": "p1rdt303", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8019fa58-ddff-4d58-9d54-6ba68f47b6af"}}}}, {"uuid": "d4d6f94f-f802-4308-9407-6b6546edf927", "name": "", "x": 38.66807769283756, "y": -122.48429523464395, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3ad84ef4-4dcc-42f7-99ed-b8d21cebc465", "name": "p1rdt177", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d4d6f94f-f802-4308-9407-6b6546edf927"}}}}, {"uuid": "4d1b6692-00b6-48e4-badf-57286e495511", "name": "", "x": 38.67120072595356, "y": -122.49044397744001, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "57a78c71-e5a8-4dfd-8359-e368b7b198fa", "name": "p1rdt306", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d1b6692-00b6-48e4-badf-57286e495511"}}}}, {"uuid": "ceeea650-e1b4-4e66-90cd-57fbde5fae70", "name": "", "x": 38.68186286213555, "y": -122.49395729632428, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6912a245-ac1c-4ddd-b021-3bc35cbbe2c5", "name": "p1rdt178", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ceeea650-e1b4-4e66-90cd-57fbde5fae70"}}}}, {"uuid": "365d0a90-7e2b-4a3a-b6cb-9ec8a40f3ee9", "name": "", "x": 38.65563774049388, "y": -122.48693753355442, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3f91816-7c3f-4fc7-98a5-6dee55e52e9f", "name": "p1rdt8105", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "365d0a90-7e2b-4a3a-b6cb-9ec8a40f3ee9"}}}}, {"uuid": "5275819a-01e1-4e57-8757-365b836edff4", "name": "", "x": 38.65332887399879, "y": -122.4877199764791, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f2c69fef-4afb-4bb3-9828-096b812de54a", "name": "p1rdt8111", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5275819a-01e1-4e57-8757-365b836edff4"}}}}, {"uuid": "d6c9dab0-2688-471e-9207-5a682545447e", "name": "", "x": 38.65397853262116, "y": -122.48734763535352, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "37229b7c-80a2-4d01-af6a-818bdfcc1f54", "name": "p1rdt8105-p1rdt8111x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d6c9dab0-2688-471e-9207-5a682545447e"}}}}, {"uuid": "0cd3484e-7c70-4cad-97ef-8a3cfa794239", "name": "", "x": 38.653298743960605, "y": -122.48786735210962, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fc34073b-94f6-4c75-8144-8f624bac9cc7", "name": "p1rdt8146", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0cd3484e-7c70-4cad-97ef-8a3cfa794239"}}}}, {"uuid": "10dac104-0d6e-41d9-8fc3-8f17a40b3a12", "name": "", "x": 38.65338804911886, "y": -122.48767001324168, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9929e0d4-3e33-4f5f-b718-6a629cc52242", "name": "p1rdt8111-p1rdt8138xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10dac104-0d6e-41d9-8fc3-8f17a40b3a12"}}}}, {"uuid": "0e5fd983-d874-4f22-ad29-f0f286977194", "name": "", "x": 38.65220693629279, "y": -122.48673933307626, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3a54311-da27-45d7-95c3-eee07761fbe4", "name": "p1rdt8111-p1rdt8138x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0e5fd983-d874-4f22-ad29-f0f286977194"}}}}, {"uuid": "fa457226-617f-4a99-b897-6225df98cda6", "name": "", "x": 38.706834415392834, "y": -122.42490821272983, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b801037a-e1bb-4c5c-8d18-ed285c8c1d3b", "name": "p1rdt251", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa457226-617f-4a99-b897-6225df98cda6"}}}}, {"uuid": "e5389bd2-8ce8-4204-97bd-aee05bb56864", "name": "", "x": 38.70723865207442, "y": -122.42480038439254, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "69b2ee46-ab5f-48c8-a26b-170ed2b57fcb", "name": "p1rdt252", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e5389bd2-8ce8-4204-97bd-aee05bb56864"}}}}, {"uuid": "39cabe12-2278-40ba-9afa-b474d3d17fae", "name": "", "x": 38.70153411123505, "y": -122.42253878409483, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3dfe357-889d-42e0-a59a-821c9f843456", "name": "p1rdt446", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "39cabe12-2278-40ba-9afa-b474d3d17fae"}}}}, {"uuid": "13201431-68c1-4d67-ab30-848923d4ecd2", "name": "", "x": 38.696509390287886, "y": -122.37572644565952, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2cf3136f-6dbe-4ed7-b9cb-e9f73b191f76", "name": "p1rdt481", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "13201431-68c1-4d67-ab30-848923d4ecd2"}}}}, {"uuid": "bb919fde-343d-4af8-b649-1a441fcbe691", "name": "", "x": 38.69562927890001, "y": -122.37574956469108, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a180b972-cf0e-4a2e-9bcf-a0ad90bb3d83", "name": "p1rdt468", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bb919fde-343d-4af8-b649-1a441fcbe691"}}}}, {"uuid": "116b3e5d-3798-43ce-a998-c53f4ba9e37b", "name": "", "x": 38.696842869414894, "y": -122.37573504621221, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c39140c6-8892-480a-81b9-738c67ed1591", "name": "p1rdt475", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "116b3e5d-3798-43ce-a998-c53f4ba9e37b"}}}}, {"uuid": "ee055b10-cabe-4d1d-8c63-0991b1e0c92a", "name": "", "x": 38.697374719659294, "y": -122.37576492139411, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fc35f44e-d8d9-41d0-b014-caa3d8d7a91e", "name": "p1rdt461", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ee055b10-cabe-4d1d-8c63-0991b1e0c92a"}}}}, {"uuid": "ec600ace-eeeb-4966-b6d6-37f79e672b78", "name": "", "x": 38.69825572660699, "y": -122.37579303954152, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2eba354c-f4bf-4c49-a8ad-998ab9489e5a", "name": "p1rdt478", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ec600ace-eeeb-4966-b6d6-37f79e672b78"}}}}, {"uuid": "84847f25-821b-400e-a799-cd3cf8fa9ba5", "name": "", "x": 38.69843582959593, "y": -122.37576847475998, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a94f7afe-e8b0-4b24-8196-6b05e98c3830", "name": "p1rdt465", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "84847f25-821b-400e-a799-cd3cf8fa9ba5"}}}}, {"uuid": "b3af6a2d-b395-43bc-805c-a33d0eac214e", "name": "", "x": 38.699753883698804, "y": -122.37577873918647, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0fa474a3-1d6b-454b-9170-6a8d13789c43", "name": "p1rdt488", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b3af6a2d-b395-43bc-805c-a33d0eac214e"}}}}, {"uuid": "bea7aa80-5487-4162-a59d-41c01b796663", "name": "", "x": 38.699988606794975, "y": -122.37585719796019, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7637cfdb-6a14-4313-95d4-e25beba178f3", "name": "p1rdt463", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bea7aa80-5487-4162-a59d-41c01b796663"}}}}, {"uuid": "d0ae0a33-8d9d-4e46-baff-4744dbc33df5", "name": "", "x": 38.701244304283534, "y": -122.3764327877571, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7627cbc6-c54a-432b-8cba-59e448f6d45a", "name": "p1rdt82", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d0ae0a33-8d9d-4e46-baff-4744dbc33df5"}}}}, {"uuid": "feb8f7d0-ddd9-49a4-9035-25a0f5fa1802", "name": "", "x": 38.701568593856685, "y": -122.37703593173678, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "36bfd1f1-80ca-4b7d-a68b-9aa77ceff96e", "name": "p1rdt78", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "feb8f7d0-ddd9-49a4-9035-25a0f5fa1802"}}}}, {"uuid": "61ff3521-9b61-4365-b8d2-19db719ca287", "name": "", "x": 38.70158095287149, "y": -122.37746615460954, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6fc415bc-f457-4e9f-bbd4-783a71b67ad6", "name": "p1rdt85", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "61ff3521-9b61-4365-b8d2-19db719ca287"}}}}, {"uuid": "8dc7b52a-7147-455e-9b0a-451e50e06055", "name": "", "x": 38.701575510504455, "y": -122.37770642721351, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "063e25be-2abb-49ae-b459-ddd08ba93bb3", "name": "p1rdt81", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8dc7b52a-7147-455e-9b0a-451e50e06055"}}}}, {"uuid": "f44e3248-9cf9-47bd-87c6-7258b7bcf930", "name": "", "x": 38.701531800163046, "y": -122.37795980901173, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b32c9763-ddff-435b-a28c-8f65111c6cb2", "name": "p1rdt79", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f44e3248-9cf9-47bd-87c6-7258b7bcf930"}}}}, {"uuid": "8e69fd51-7eb9-4fd3-b2d6-8a48a810d9a3", "name": "", "x": 38.70139571168677, "y": -122.37841744526864, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dfbb212a-9882-4468-86ac-578c93fde1d8", "name": "p1rdt76", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8e69fd51-7eb9-4fd3-b2d6-8a48a810d9a3"}}}}, {"uuid": "28739721-e132-4b04-86a9-56f6ea3da7da", "name": "", "x": 38.70130561638834, "y": -122.3796880720142, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7c543753-fa26-41df-b7a6-3664395c0d45", "name": "p1rdt31", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "28739721-e132-4b04-86a9-56f6ea3da7da"}}}}, {"uuid": "62463952-0717-41bf-9839-1f1550b7af30", "name": "", "x": 38.70185707821067, "y": -122.38044898464344, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e8dcdfef-b40e-4f1c-9b7c-e84846f68c5a", "name": "p1rdt36", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "62463952-0717-41bf-9839-1f1550b7af30"}}}}, {"uuid": "9101c6b5-0c1a-49cf-a987-2070793803fa", "name": "", "x": 38.702744402653344, "y": -122.38060588011899, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "834e959c-8ee6-4fff-b1fc-54c20fc0f20b", "name": "p1rdt32", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9101c6b5-0c1a-49cf-a987-2070793803fa"}}}}, {"uuid": "f4a0f3e7-a651-456a-8d40-60652fb7afc2", "name": "", "x": 38.70315433826527, "y": -122.38036878848187, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "80331f15-8b31-454c-a289-49cb79923252", "name": "p1rdt234", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f4a0f3e7-a651-456a-8d40-60652fb7afc2"}}}}, {"uuid": "2d354866-5878-4547-971d-7695b52967f8", "name": "", "x": 38.70342202813448, "y": -122.37754091771487, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8f5ed5d5-93fc-4f3c-a78b-df7019863b67", "name": "p1rdt233", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2d354866-5878-4547-971d-7695b52967f8"}}}}, {"uuid": "ff295c7d-9e68-4562-91ff-1c05b39881db", "name": "", "x": 38.70364344183274, "y": -122.37626641561926, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "445f61a4-8045-4558-a3c1-bb44336737ec", "name": "p1rdt485", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ff295c7d-9e68-4562-91ff-1c05b39881db"}}}}, {"uuid": "5593c229-b3c9-4d0d-bc4f-0be1328a3af8", "name": "", "x": 38.70340510620564, "y": -122.37837704887761, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "190d6c51-94b6-462e-8fee-cce57f1ab66d", "name": "p1rdt236", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5593c229-b3c9-4d0d-bc4f-0be1328a3af8"}}}}, {"uuid": "673128da-caab-4282-9357-c1d62f2c2ece", "name": "", "x": 38.70289903823247, "y": -122.38150952694326, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "14b85850-d83e-4a5e-83c3-ccb485bb85aa", "name": "p1rdt235", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "673128da-caab-4282-9357-c1d62f2c2ece"}}}}, {"uuid": "a374df4b-0d29-44b7-9bac-64b8948c031e", "name": "", "x": 38.70241528605291, "y": -122.38205420706528, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4fa95a19-0e0a-49b3-bb86-7103fbaa4110", "name": "p1rdt30", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a374df4b-0d29-44b7-9bac-64b8948c031e"}}}}, {"uuid": "27886ea0-4c87-411a-b113-73a096f62fda", "name": "", "x": 38.70180761889256, "y": -122.38302545203672, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "edc22f66-e919-448e-b990-76033c281d43", "name": "p1rdt35", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "27886ea0-4c87-411a-b113-73a096f62fda"}}}}, {"uuid": "236076ef-b7c1-4fb9-8263-b3a045928901", "name": "", "x": 38.70163145569769, "y": -122.3837974760483, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1e9f4b13-5fb5-46b2-9258-83582d47d61a", "name": "p1rdt84", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "236076ef-b7c1-4fb9-8263-b3a045928901"}}}}, {"uuid": "7b7eef78-375f-456d-852b-00b1d572d559", "name": "", "x": 38.70166339444126, "y": -122.38472871487578, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f55e4012-a11d-4883-baac-9c013aff6058", "name": "p1rdt33", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7b7eef78-375f-456d-852b-00b1d572d559"}}}}, {"uuid": "247189ff-cc8a-46c5-a8c4-302aa83aca0a", "name": "", "x": 38.7017418716262, "y": -122.38534278443267, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a01c83d1-4adb-4b2a-8de3-441d7c1dd054", "name": "p1rdt39", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "247189ff-cc8a-46c5-a8c4-302aa83aca0a"}}}}, {"uuid": "bd8ee146-d20a-4486-a4a6-8cc95bd84b7d", "name": "", "x": 38.701720915150304, "y": -122.38552827095313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dc531967-1a7b-4424-83ee-e1131c6fd94c", "name": "p1rdt73", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bd8ee146-d20a-4486-a4a6-8cc95bd84b7d"}}}}, {"uuid": "93962e5e-5dec-4444-8f0a-d3dcffea81d1", "name": "", "x": 38.70178214782518, "y": -122.38611126603591, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "510ea93c-7dd1-4fa3-ba3f-6c362856c7c1", "name": "p1rdt75", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "93962e5e-5dec-4444-8f0a-d3dcffea81d1"}}}}, {"uuid": "31ad3b66-1fa1-490b-bef3-43e3c128eca3", "name": "", "x": 38.70181286232661, "y": -122.3868125146921, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0aa0b7c2-9d55-4faf-8778-76a6f23bcf3e", "name": "p1rdt83", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "31ad3b66-1fa1-490b-bef3-43e3c128eca3"}}}}, {"uuid": "526cccc9-2c2a-4ed8-afcb-3a615e136d3a", "name": "", "x": 38.70215867171945, "y": -122.38789186166865, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b03f8e29-a5b2-4bed-b68c-219276674b6a", "name": "p1rdt80", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "526cccc9-2c2a-4ed8-afcb-3a615e136d3a"}}}}, {"uuid": "be8ad268-a3cf-443d-a0ec-9b264dda0a90", "name": "", "x": 38.697976462001364, "y": -122.39194580684853, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6e26e5dc-8c98-4fcd-b125-3265eb00f3f2", "name": "p1rdt263", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be8ad268-a3cf-443d-a0ec-9b264dda0a90"}}}}, {"uuid": "e49f82ab-a211-49e8-85c6-8633476c0695", "name": "", "x": 38.69710687368567, "y": -122.39904337583427, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "add5e39f-f02e-4a61-a156-d5721cec25d5", "name": "p1rdt277", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e49f82ab-a211-49e8-85c6-8633476c0695"}}}}, {"uuid": "78223a48-666e-4fcb-bebe-4311d1ecde6b", "name": "", "x": 38.69810207651738, "y": -122.40314189875019, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "186ffdfe-2346-4218-bd6b-b813ea6b3b62", "name": "p1rdt276", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "78223a48-666e-4fcb-bebe-4311d1ecde6b"}}}}, {"uuid": "01232a55-73d4-431f-b4e2-ab26730f7c11", "name": "", "x": 38.690000449751984, "y": -122.37232330919996, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9396562e-4f87-4e04-b248-502b851fe19e", "name": "p1rdt69", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "01232a55-73d4-431f-b4e2-ab26730f7c11"}}}}, {"uuid": "c3618ba1-cc9e-482c-b16e-58f3afed5c90", "name": "", "x": 38.689693582568, "y": -122.3712823494636, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b1bf1493-fb0d-40b4-8953-42e851a128d1", "name": "p1rdt44-p1rdt69x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c3618ba1-cc9e-482c-b16e-58f3afed5c90"}}}}, {"uuid": "abafd7f4-0cb8-4405-b252-6d3fa278f0eb", "name": "", "x": 38.68937758378194, "y": -122.37014905131693, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d9ee2ff-e2bc-4d76-b173-5ba5cc48c9b3", "name": "p1rdt44", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "abafd7f4-0cb8-4405-b252-6d3fa278f0eb"}}}}, {"uuid": "03aced16-e52e-475b-a740-04f3b1bf820b", "name": "", "x": 38.69011879726304, "y": -122.37274288833332, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f5b5b3ae-f657-4fd4-a311-ab1dbe9d749e", "name": "p1rdt41", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "03aced16-e52e-475b-a740-04f3b1bf820b"}}}}, {"uuid": "36d91d90-2790-49d6-b119-47c834f4234b", "name": "", "x": 38.690503780808164, "y": -122.3733294899771, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5a898f4c-f522-4e69-be4a-e935e339e011", "name": "p1rdt54", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "36d91d90-2790-49d6-b119-47c834f4234b"}}}}, {"uuid": "aaa1d980-d87f-4d7b-ac4e-4b123d9d1355", "name": "", "x": 38.690543520806486, "y": -122.37401904570497, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a778171c-22a1-4320-9e3c-43888d734e34", "name": "p1rdt42", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aaa1d980-d87f-4d7b-ac4e-4b123d9d1355"}}}}, {"uuid": "947f010e-99dd-41e2-96b2-bffab8e65938", "name": "", "x": 38.69014061173149, "y": -122.37513434619457, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "29a79372-9c75-4a9c-81df-a7491b87e58a", "name": "p1rdt45", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "947f010e-99dd-41e2-96b2-bffab8e65938"}}}}, {"uuid": "b407de02-85af-4ee9-8cd1-d1819848c2a8", "name": "", "x": 38.69057727021838, "y": -122.39183596993689, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "12451cbc-eb14-4814-b274-12eb2241c78a", "name": "p1rdt150", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b407de02-85af-4ee9-8cd1-d1819848c2a8"}}}}, {"uuid": "20710a8e-91b2-4c39-a742-bbc05da3aea2", "name": "", "x": 38.690031528872375, "y": -122.37717801542972, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "666bb367-692a-4127-8f77-d86d651768a1", "name": "p1rdt150-p1rdt45x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "20710a8e-91b2-4c39-a742-bbc05da3aea2"}}}}, {"uuid": "8ae76df5-4eda-4ab4-b4a6-5a6cc3bc0572", "name": "", "x": 38.694133300872906, "y": -122.39690517522077, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ba0ef4a3-43ba-469b-8ce8-ca7a5a984071", "name": "p1rdt260", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8ae76df5-4eda-4ab4-b4a6-5a6cc3bc0572"}}}}, {"uuid": "d3ad0f96-fc3e-4803-a9e7-5fb27f447339", "name": "", "x": 38.693518695228036, "y": -122.39600590196753, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e885b3e5-18fb-4454-b8e7-d82b4c72f6e8", "name": "p1rdt150-p1rdt260x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d3ad0f96-fc3e-4803-a9e7-5fb27f447339"}}}}, {"uuid": "3163f4ff-97fe-45fc-a29c-50928b93536f", "name": "", "x": 38.69620897416254, "y": -122.40296066033352, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "153bb615-5ee5-4eec-bcf7-94ea0098aeb6", "name": "p1rdt279", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3163f4ff-97fe-45fc-a29c-50928b93536f"}}}}, {"uuid": "a8a933b7-550e-458e-a813-a122f7e87ffb", "name": "", "x": 38.69807607310296, "y": -122.40309926707015, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7140d97e-416e-47ec-9f86-46ad6f9abece", "name": "p1rdt276-p1rdt279x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8a933b7-550e-458e-a813-a122f7e87ffb"}}}}, {"uuid": "aa93ecf8-6317-4e7e-8477-1c893b5d069b", "name": "", "x": 38.69819542243506, "y": -122.40314157925388, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c3ca9bee-26b0-4ef4-8555-6494ffdd6a17", "name": "p1rdt237-p1rdt276x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aa93ecf8-6317-4e7e-8477-1c893b5d069b"}}}}, {"uuid": "0ca3bc30-a32a-4240-89b1-4f3e26a789a5", "name": "", "x": 38.69933414700199, "y": -122.4089172598197, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "767b59ef-ecd9-4b17-8233-2033a02b2971", "name": "p1rdt237-p1rdt276xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0ca3bc30-a32a-4240-89b1-4f3e26a789a5"}}}}, {"uuid": "3781b958-1ce3-4d50-b11e-7a414f9249c8", "name": "", "x": 38.70123224209162, "y": -122.42082954062212, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "11571d26-573f-49f7-99fd-828dde97afd8", "name": "p1rdt445", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3781b958-1ce3-4d50-b11e-7a414f9249c8"}}}}, {"uuid": "597b89b3-1ee6-4948-af20-fb9177ddd8a9", "name": "", "x": 38.69940195487717, "y": -122.41580111174017, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b8c8b8f8-7a41-4d16-b509-2d7c7af9509d", "name": "p1rdt237", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "597b89b3-1ee6-4948-af20-fb9177ddd8a9"}}}}, {"uuid": "6c603289-21a7-43aa-9f84-f41ba7f6e016", "name": "", "x": 38.701258982520905, "y": -122.42203851637785, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "10620dcc-049c-4417-b4ac-922a56c0d4a2", "name": "p1rdt438", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c603289-21a7-43aa-9f84-f41ba7f6e016"}}}}, {"uuid": "cc52b747-000a-4eb9-8b06-9966684ef16d", "name": "", "x": 38.689358814642475, "y": -122.44266212701238, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e71eb2d5-cd10-498d-b9eb-ae337b2f8af6", "name": "p1rdt28", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc52b747-000a-4eb9-8b06-9966684ef16d"}}}}, {"uuid": "564731ca-f9e0-45c3-9794-cebe993202f6", "name": "", "x": 38.68721403983049, "y": -122.44207560107604, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b238dc5-7d8e-4b2d-8449-4dc212d7d227", "name": "p1rdt29", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "564731ca-f9e0-45c3-9794-cebe993202f6"}}}}, {"uuid": "9d4e97bd-a73c-4ed1-aad4-1c56fcfeb7f5", "name": "", "x": 38.68513046534505, "y": -122.45203222088253, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b07c4a6-39a7-4521-bce7-3f1ca0ff4a66", "name": "p1rdt335", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9d4e97bd-a73c-4ed1-aad4-1c56fcfeb7f5"}}}}, {"uuid": "74004cc2-1c07-40eb-b690-9af1a3df1329", "name": "", "x": 38.672940788437906, "y": -122.46748581101485, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d2efeaf5-2055-4718-a064-7c5e00b7d87d", "name": "p1rdt335-p1rdt419x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "74004cc2-1c07-40eb-b690-9af1a3df1329"}}}}, {"uuid": "bd6d72a5-0be7-43d2-8bdd-a587714676de", "name": "", "x": 38.670797093100916, "y": -122.46774549226095, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4cf05060-0a39-49a9-a761-79fb136e2965", "name": "p1rdt420", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bd6d72a5-0be7-43d2-8bdd-a587714676de"}}}}, {"uuid": "a7442dd9-11f1-4aa7-b011-7fe9acac7b86", "name": "", "x": 38.67291356677607, "y": -122.46744017800017, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "81cfd2a2-295c-4b73-abba-05ffee810523", "name": "p1rdt419", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a7442dd9-11f1-4aa7-b011-7fe9acac7b86"}}}}, {"uuid": "31607d9b-e1df-4994-b05a-19e19b826848", "name": "", "x": 38.66669420046755, "y": -122.46979269819516, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2eb3d4eb-71fc-46f3-b588-d223568c411c", "name": "p1rdt8167", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "31607d9b-e1df-4994-b05a-19e19b826848"}}}}, {"uuid": "755607de-9ddc-4da7-90ee-fa14c364aa50", "name": "", "x": 38.66526952797366, "y": -122.47022403577644, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3c93a476-4ad5-41cd-a07b-e2ccc9ef2c3b", "name": "p1rdt8180", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "755607de-9ddc-4da7-90ee-fa14c364aa50"}}}}, {"uuid": "ba2d9fb2-095f-4bb5-8b20-417d9d825944", "name": "", "x": 38.66479901416412, "y": -122.46771598894871, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f6bdb2cf-9373-4d56-a5f9-cb8fa9c67e55", "name": "p1rdt8169", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ba2d9fb2-095f-4bb5-8b20-417d9d825944"}}}}, {"uuid": "1859b7c8-60c3-43f1-b2f2-20c000be300e", "name": "", "x": 38.66152380322448, "y": -122.47383733708416, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "498a07ee-e12b-459a-a01f-f663a4a8428a", "name": "p1rdt8174-p1rdt8180x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1859b7c8-60c3-43f1-b2f2-20c000be300e"}}}}, {"uuid": "91f2ce3d-3736-4c91-8287-a517bda95203", "name": "", "x": 38.6604983255136, "y": -122.47346682060977, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8997dae6-8970-4762-98e9-0617375633d6", "name": "p1rdt8195", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "91f2ce3d-3736-4c91-8287-a517bda95203"}}}}, {"uuid": "d9edddcb-9fa1-475f-9bf6-503a8412b109", "name": "", "x": 38.66147939586647, "y": -122.47384646091422, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6b0f9433-e0a3-458a-8687-c9cf38d0bbb3", "name": "p1rdt8174", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d9edddcb-9fa1-475f-9bf6-503a8412b109"}}}}, {"uuid": "cb97c63c-d7ff-485c-9dfe-4e26ebff9985", "name": "", "x": 38.658272650826795, "y": -122.47501655241358, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "081feb5c-d5d5-405e-85d4-f1dd0916fc3d", "name": "p1rdt7757", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb97c63c-d7ff-485c-9dfe-4e26ebff9985"}}}}, {"uuid": "14c338c8-ab4b-486b-a84b-27dda3b552bc", "name": "", "x": 38.655197924044465, "y": -122.48096925268166, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "68117bef-16c5-40c9-9356-76ef5c056650", "name": "p1rdt5560", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "14c338c8-ab4b-486b-a84b-27dda3b552bc"}}}}, {"uuid": "cd9b5143-5e3c-47a8-8356-96be17119efb", "name": "", "x": 38.6571578603823, "y": -122.47877412021943, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b64b7bd6-06e4-45f7-b987-efc7d09b91f8", "name": "p1rdt5560-p1rdt7757x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cd9b5143-5e3c-47a8-8356-96be17119efb"}}}}, {"uuid": "7a8878fb-4cdc-4fa9-b40d-55bc8657a357", "name": "", "x": 38.6544084693578, "y": -122.48126098888899, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8444c9ea-ff7a-4b0a-9ea6-9c18770565cb", "name": "p1rdt5564", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7a8878fb-4cdc-4fa9-b40d-55bc8657a357"}}}}, {"uuid": "c1427e78-5470-44e6-90f6-405b0dcda489", "name": "", "x": 38.65411176650942, "y": -122.48165516473325, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ad24f98d-f022-4e62-b80b-426052810759", "name": "p1rdt5563", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c1427e78-5470-44e6-90f6-405b0dcda489"}}}}, {"uuid": "ad5db67d-1964-4568-ad89-8f27ba79aa8d", "name": "", "x": 38.65399305368811, "y": -122.48234388532953, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c94489ed-4399-4dab-bab6-02b79f240f63", "name": "p1rdt5557-p1rdt5563x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ad5db67d-1964-4568-ad89-8f27ba79aa8d"}}}}, {"uuid": "b159b55d-cc9f-46ad-bf19-5d08b45496f4", "name": "", "x": 38.65409795953588, "y": -122.48170621590174, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fbc31b75-f942-4bae-8712-f1666d8b7f26", "name": "p1rdt5557-p1rdt5563xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b159b55d-cc9f-46ad-bf19-5d08b45496f4"}}}}, {"uuid": "cbcd009a-0c20-4d15-a018-6b45b447e5a2", "name": "", "x": 38.65386072697981, "y": -122.48298842075683, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "efe7243f-340b-4114-be7c-f7494e78384f", "name": "p1rdt5557-p1rdt5565xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cbcd009a-0c20-4d15-a018-6b45b447e5a2"}}}}, {"uuid": "0a21d5f6-b987-4af0-8cad-052a586d9aaf", "name": "", "x": 38.6540547104338, "y": -122.48228339829146, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bfe92e2e-285d-4c58-8e0b-a462dd73fa41", "name": "p1rdt5557-p1rdt5565x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a21d5f6-b987-4af0-8cad-052a586d9aaf"}}}}, {"uuid": "53b7a282-efd7-49b9-8b4c-e3660d062d2f", "name": "", "x": 38.653744336845875, "y": -122.48342339339821, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8bd0860f-2b3e-4c90-a571-cfc6aa649e5b", "name": "p1rdt5561-p1rdt5565x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "53b7a282-efd7-49b9-8b4c-e3660d062d2f"}}}}, {"uuid": "83fe7a48-cf07-4fea-aee2-6f82ef002e17", "name": "", "x": 38.653922384064785, "y": -122.48292793438009, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bebca5d7-2d4f-4655-a965-9faafd7a8125", "name": "p1rdt5561-p1rdt5565xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "83fe7a48-cf07-4fea-aee2-6f82ef002e17"}}}}, {"uuid": "e16a0510-15af-4338-ad06-536625606dae", "name": "", "x": 38.653656874338274, "y": -122.48382172207613, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "27ab530f-a58e-4113-80f6-63f768910204", "name": "p1rdt5551-p1rdt5561x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e16a0510-15af-4338-ad06-536625606dae"}}}}, {"uuid": "4d8bd976-82f1-4fab-984f-87546cf80006", "name": "", "x": 38.65368267949884, "y": -122.4834838792017, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bf97a458-469e-4609-bb33-97454e7c2b68", "name": "p1rdt5551-p1rdt5561xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d8bd976-82f1-4fab-984f-87546cf80006"}}}}, {"uuid": "0d7f3c2b-6d04-41bd-b92d-4a2665f338a3", "name": "", "x": 38.65357363505309, "y": -122.48418848997771, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d447cf8-7b2b-45f1-8084-6fe4897e1853", "name": "p1rdt5548-p1rdt5551x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0d7f3c2b-6d04-41bd-b92d-4a2665f338a3"}}}}, {"uuid": "bf13386c-86ca-40dc-8ce9-f0367315b4ae", "name": "", "x": 38.65359832142837, "y": -122.48384598170813, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5ec70f12-a676-48cd-b626-34f8d7f6a5bf", "name": "p1rdt5548-p1rdt5551xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bf13386c-86ca-40dc-8ce9-f0367315b4ae"}}}}, {"uuid": "58902d6a-effa-4407-ade5-fc151647b853", "name": "", "x": 38.65344193779202, "y": -122.48465054385285, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "10f43169-4b4b-4dbe-8f09-af72d427d6c7", "name": "p1rdt5548-p1rdt5566xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "58902d6a-effa-4407-ade5-fc151647b853"}}}}, {"uuid": "fa35428d-ad2e-4833-92af-155777d08869", "name": "", "x": 38.65355345327659, "y": -122.48411429646117, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "23163dba-070c-435c-bb90-77be7ded002a", "name": "p1rdt5548-p1rdt5566x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa35428d-ad2e-4833-92af-155777d08869"}}}}, {"uuid": "62505c49-18d7-4dc7-88a2-27afcb42e823", "name": "", "x": 38.65349305461597, "y": -122.48469671958328, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bf619f04-1fa5-4be7-8a76-669b79436d3e", "name": "p1rdt5566-p1rdt5574xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "62505c49-18d7-4dc7-88a2-27afcb42e823"}}}}, {"uuid": "d3ac96ef-09fb-4bae-b143-3a065d9d9ad1", "name": "", "x": 38.65351374951022, "y": -122.48468872832316, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c264e6de-a898-421d-a2fe-ce6548aa477e", "name": "p1rdt5566-p1rdt5574x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d3ac96ef-09fb-4bae-b143-3a065d9d9ad1"}}}}, {"uuid": "06702de2-f8c8-4589-8236-bca704fa692d", "name": "", "x": 38.6521229408726, "y": -122.4867812786121, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "17b633c6-214d-4428-bded-df737f50ffb6", "name": "p1rdt8138", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "06702de2-f8c8-4589-8236-bca704fa692d"}}}}, {"uuid": "0173173b-eac5-4e26-8f41-c21afd87760e", "name": "", "x": 38.65212339039547, "y": -122.48678923108443, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2c8fd701-7842-49c1-b630-7ae1ad49739f", "name": "p1rdt5574-p1rdt8138x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0173173b-eac5-4e26-8f41-c21afd87760e"}}}}, {"uuid": "7596258b-68d1-4f85-b881-4661a9159a6c", "name": "", "x": 38.6534675320259, "y": -122.48473979533868, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e9906676-e9b9-4d51-b1c2-a6b6fe187faa", "name": "p1rdt5574", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7596258b-68d1-4f85-b881-4661a9159a6c"}}}}, {"uuid": "2f74bd6e-72a9-42da-a509-e0390ecfbf81", "name": "", "x": 38.64755444307129, "y": -122.50915596024865, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "63b2f1e6-5e15-4433-85ee-ff7bb7218b96", "name": "p1rdt6488", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2f74bd6e-72a9-42da-a509-e0390ecfbf81"}}}}, {"uuid": "0bbf498a-e4cc-40d6-a250-682263afe9bd", "name": "", "x": 38.647519963483695, "y": -122.50475738860712, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "548ba541-a511-486c-876c-c841a6e482af", "name": "p1rdt6488-p1rdt8138x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0bbf498a-e4cc-40d6-a250-682263afe9bd"}}}}, {"uuid": "e0bc28a4-d366-4769-b729-d481f566e45b", "name": "", "x": 38.653569957917405, "y": -122.48377667700575, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a9dec144-ef2e-44fe-990a-c9d70b740410", "name": "p1rdt5551lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e0bc28a4-d366-4769-b729-d481f566e45b"}}}}, {"uuid": "0edb9ce5-61b9-441c-8a5a-d23c20926863", "name": "", "x": 38.653349320804885, "y": -122.48361706572747, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "82988650-787d-41de-bca7-4f3c08ccad15", "name": "p1rlv11506", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0edb9ce5-61b9-441c-8a5a-d23c20926863"}}}}, {"uuid": "a749a880-49d7-464e-abad-60ef90fb20cf", "name": "", "x": 38.65393253922449, "y": -122.48302660355507, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60dc1291-a843-4abf-bfc6-ff8afc8c0b98", "name": "p1rdt5565lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a749a880-49d7-464e-abad-60ef90fb20cf"}}}}, {"uuid": "edd8090c-62f3-41ba-b6c3-d35d218dc4e9", "name": "", "x": 38.65344458882935, "y": -122.48274295264503, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "176b348f-9ecf-4a82-bdf9-f2e5d5a07af7", "name": "p1rlv11522", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "edd8090c-62f3-41ba-b6c3-d35d218dc4e9"}}}}, {"uuid": "f15e74bc-cd3f-4502-bdbc-ac249f73eea8", "name": "", "x": 38.65413728795049, "y": -122.4816120875077, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0a150dd3-61a4-4df9-90e2-6c72f80af819", "name": "p1rdt5563lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f15e74bc-cd3f-4502-bdbc-ac249f73eea8"}}}}, {"uuid": "4ba1e7ab-c731-42a2-b1cf-1a4a3eee3337", "name": "", "x": 38.65368296548394, "y": -122.48162646334242, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "22054033-4e69-41b0-b321-a4d086d20574", "name": "p1rlv11520", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ba1e7ab-c731-42a2-b1cf-1a4a3eee3337"}}}}, {"uuid": "2721271a-309e-4478-a9f3-411791dd008f", "name": "", "x": 38.707239856986014, "y": -122.42485436421835, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c5fd6466-e740-4f06-a842-798195d62154", "name": "p1rdt252lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2721271a-309e-4478-a9f3-411791dd008f"}}}}, {"uuid": "8c301039-3b06-4026-9cfd-61173d74a637", "name": "", "x": 38.70723070261674, "y": -122.4249071150479, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a23f97bc-e7ef-4f64-9e64-314f4a4e17d8", "name": "p1rlv440", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8c301039-3b06-4026-9cfd-61173d74a637"}}}}, {"uuid": "beb8a8dd-d1ae-4c46-a0b8-9164b1204cd1", "name": "", "x": 38.65363370971865, "y": -122.48373653900416, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "514ad102-b590-4ad8-a258-2b6fa8dcbeb1", "name": "p1rdt5551-p1rdt5568x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "beb8a8dd-d1ae-4c46-a0b8-9164b1204cd1"}}}}, {"uuid": "5fd03be4-748d-4158-a92d-24b0cc0a9305", "name": "", "x": 38.65350635684874, "y": -122.48421628994025, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25ee6008-ddbc-4e7b-8a57-ff38c16368a2", "name": "p1rdt5548-p1rdt5577x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5fd03be4-748d-4158-a92d-24b0cc0a9305"}}}}, {"uuid": "bf563631-9bac-4a2c-9536-752dae925812", "name": "", "x": 38.65213674275478, "y": -122.48364605819339, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1c8b424-4509-4fd2-93e2-4fd54f6cf49a", "name": "p1rdt5577", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bf563631-9bac-4a2c-9536-752dae925812"}}}}, {"uuid": "406f41ee-91ce-4a71-849a-80eed4ccd2c4", "name": "", "x": 38.65403765024386, "y": -122.48233644072755, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cca8918c-30e6-4619-a5e0-8c0d3451f9c4", "name": "p1rdt5557", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "406f41ee-91ce-4a71-849a-80eed4ccd2c4"}}}}, {"uuid": "bbda2575-698a-42f3-b5bf-3a83b99b842a", "name": "", "x": 38.65390532358046, "y": -122.48298097656864, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b5e479d3-aae0-47b8-b707-bad1191df1e7", "name": "p1rdt5565", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bbda2575-698a-42f3-b5bf-3a83b99b842a"}}}}, {"uuid": "c0e900d1-a01a-4a5a-9d85-1a6d12778a63", "name": "", "x": 38.65372727613462, "y": -122.48347643534002, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "756f6cd8-301b-4fac-b414-d72853616c6e", "name": "p1rdt5561", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c0e900d1-a01a-4a5a-9d85-1a6d12778a63"}}}}, {"uuid": "ddd5810d-928e-4fa9-96db-426ae8d4092e", "name": "", "x": 38.653615927095316, "y": -122.48379127781236, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5f7fed4f-197e-4a79-97e5-df595377736b", "name": "p1rdt5551", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ddd5810d-928e-4fa9-96db-426ae8d4092e"}}}}, {"uuid": "99b54ad7-1ddb-4d8c-8305-c45ad70177b3", "name": "", "x": 38.653529895117565, "y": -122.48416522717811, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6bf1b63d-fbce-42f8-9948-2e09bfa67409", "name": "p1rdt5548", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "99b54ad7-1ddb-4d8c-8305-c45ad70177b3"}}}}, {"uuid": "25286f23-9994-4df7-a510-04d00e26e939", "name": "", "x": 38.65348653464999, "y": -122.48464310081867, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9fed9557-b170-4817-8bd8-efc3b9f7c982", "name": "p1rdt5566", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "25286f23-9994-4df7-a510-04d00e26e939"}}}}, {"uuid": "1f82ec4b-389f-44b2-8e92-0331097de9d4", "name": "", "x": 38.65857449295584, "y": -122.51047390361627, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16ace27f-f5fa-4fd1-840e-8cae55dbe1b2", "name": "p1rdt383-p1rdt7300x_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1f82ec4b-389f-44b2-8e92-0331097de9d4"}}}}, {"uuid": "11d5fb2d-a11f-4cca-a32d-a54a006ec224", "name": "", "x": 38.755774152251824, "y": -122.36924141377668, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e6b5c947-b0c5-4e20-bd74-bf847bdacd30", "name": "p1rdt181_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "11d5fb2d-a11f-4cca-a32d-a54a006ec224"}}}}, {"uuid": "a94365ec-ba7e-41ad-9b88-27ea9076b835", "name": "", "x": 38.76763103931847, "y": -122.38059245720176, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "99615f32-0614-4c23-a1e1-b3e8e5688cce", "name": "p1rdt66", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a94365ec-ba7e-41ad-9b88-27ea9076b835"}}}}, {"uuid": "8e2b886e-e1fc-41ea-a1e8-76febb13f1e2", "name": "", "x": 38.73066670610679, "y": -122.39985796643494, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "71abd5f1-ca61-4754-a2ef-7b5d4e635f99", "name": "p1rdt181-p1rdt297x_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8e2b886e-e1fc-41ea-a1e8-76febb13f1e2"}}}}, {"uuid": "4d02be35-fcba-456e-b90e-38db765a0ac1", "name": "", "x": 38.73098682493839, "y": -122.41321244241928, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b0fad7ee-b65c-460c-94ca-fe9546a5b140", "name": "p1rdt270-p1rdt298x_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d02be35-fcba-456e-b90e-38db765a0ac1"}}}}, {"uuid": "639ab63c-d85d-49e0-bfb2-74b043b6dcba", "name": "", "x": 38.68766311446792, "y": -122.34290029588801, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b8064f1d-11b7-4913-8344-175c1388be3e", "name": "p1rdt16604-p1rdt257x_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "639ab63c-d85d-49e0-bfb2-74b043b6dcba"}}}}, {"uuid": "d63106f2-69d0-425e-9c68-7a00109bd753", "name": "", "x": 38.6006266312945, "y": -122.52427556411426, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e2131350-dc34-4d8d-8c9f-c29e25bc654c", "name": "p1rdt7711", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d63106f2-69d0-425e-9c68-7a00109bd753"}}}}, {"uuid": "15ce6336-bc93-4d4a-8034-cf23d75b7464", "name": "", "x": 38.60058489010104, "y": -122.52426789727744, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "64b60527-0853-4973-8d7a-78ba5e377799", "name": "p1rdt7711lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "15ce6336-bc93-4d4a-8034-cf23d75b7464"}}}}, {"uuid": "b247caad-f974-4017-a99d-5bfa5bf2b928", "name": "", "x": 38.600468680548644, "y": -122.5242248045325, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3ed6276c-a57b-40be-a1f1-34aaaba0ac28", "name": "p1rlv16411", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b247caad-f974-4017-a99d-5bfa5bf2b928"}}}}, {"uuid": "a07a22f5-d840-47dd-9319-457197a96756", "name": "", "x": 38.60059554402563, "y": -122.52439622804972, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e0a92e79-0ca2-4a10-9050-9e8d7442b019", "name": "p1rlv20414", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a07a22f5-d840-47dd-9319-457197a96756"}}}}, {"uuid": "6eedbed5-071e-429f-9cb3-c1cf4e13a452", "name": "", "x": 38.59743372341483, "y": -122.52848624702995, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "439728c5-fee5-4dfa-9894-261ba6c40e95", "name": "p1rdt8473lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6eedbed5-071e-429f-9cb3-c1cf4e13a452"}}}}, {"uuid": "8f49bd92-9100-4688-a6c3-8c7dab784aa0", "name": "", "x": 38.59755648297391, "y": -122.52834367013348, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3c1eac45-623a-4f0a-874d-a4b56a8e2ea7", "name": "p1rlv18169", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8f49bd92-9100-4688-a6c3-8c7dab784aa0"}}}}, {"uuid": "c750bbe3-7c46-4b17-8dda-052506550e67", "name": "", "x": 38.59726926605651, "y": -122.52863263826859, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "949f4cce-f321-4bf0-830b-489edc9964c7", "name": "p1rlv18194", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c750bbe3-7c46-4b17-8dda-052506550e67"}}}}, {"uuid": "c7fc9e30-46b9-4818-b666-3885d4c69c23", "name": "", "x": 38.5973486590682, "y": -122.53115453060339, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35f6f747-811d-4fe2-a9c7-991248572c74", "name": "p1rdt6028lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c7fc9e30-46b9-4818-b666-3885d4c69c23"}}}}, {"uuid": "d612deb0-ae01-4e0e-8f3c-4dc7320ec9aa", "name": "", "x": 38.597359644970844, "y": -122.53094024225281, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "72f659b6-d302-4887-a2f6-1a477ad3324c", "name": "p1rlv12518", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d612deb0-ae01-4e0e-8f3c-4dc7320ec9aa"}}}}, {"uuid": "f82d5b04-ca0c-4334-a89a-1e8dcc3def3c", "name": "", "x": 38.597740803009394, "y": -122.53160381152783, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f9660b80-0fce-4be4-b541-743d5811133c", "name": "p1rlv12528", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f82d5b04-ca0c-4334-a89a-1e8dcc3def3c"}}}}, {"uuid": "0d020d98-a846-403c-9afb-ee0db1c7029d", "name": "", "x": 38.59730635717321, "y": -122.53113580939358, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8796d817-aad6-4d22-b3d4-baf8a686c9df", "name": "p1rlv12534", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0d020d98-a846-403c-9afb-ee0db1c7029d"}}}}, {"uuid": "7e1a9607-6da1-4730-9899-d1a9821d629a", "name": "", "x": 38.597059503153865, "y": -122.53096119189571, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e89452f3-ce44-46d3-a259-f66044e01c2c", "name": "p1rlv12536", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7e1a9607-6da1-4730-9899-d1a9821d629a"}}}}, {"uuid": "64714c99-eb77-45de-8558-c4ccb0182909", "name": "", "x": 38.598068610661386, "y": -122.54952501293569, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ddf38626-1223-429f-a903-98f1c975020b", "name": "p1rdt9478lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "64714c99-eb77-45de-8558-c4ccb0182909"}}}}, {"uuid": "f8becd39-60a8-4e1e-9c22-bb224d6ad808", "name": "", "x": 38.59809415769325, "y": -122.54948199323535, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cebe1b53-cca6-4bd4-a9f0-616ffb9750b3", "name": "p1rlv20501", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f8becd39-60a8-4e1e-9c22-bb224d6ad808"}}}}, {"uuid": "eba7b3a6-8113-470f-a84e-d5f0ed18ecb5", "name": "", "x": 38.59772028985937, "y": -122.55034252722092, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3e2630e1-a215-4740-9327-fa004e89863d", "name": "p1rdt6232lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eba7b3a6-8113-470f-a84e-d5f0ed18ecb5"}}}}, {"uuid": "6d3aa3aa-641b-4303-8721-8f50561f013f", "name": "", "x": 38.59770645245217, "y": -122.5503935254409, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "df3aae83-f4b0-4db2-9301-dff1664ac23e", "name": "p1rlv12985", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6d3aa3aa-641b-4303-8721-8f50561f013f"}}}}, {"uuid": "abda40da-fda1-41de-a3fa-a0c7ca091e4f", "name": "", "x": 38.59805477361372, "y": -122.54957601155624, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c49b6e87-5834-4e7e-a64c-b4ec0f7d4995", "name": "p1rdt9478", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "abda40da-fda1-41de-a3fa-a0c7ca091e4f"}}}}, {"uuid": "7465d552-f9fd-4c18-bbcb-046e2214089f", "name": "", "x": 38.59774583719626, "y": -122.55029950801654, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b59ad93a-cca2-4a77-8515-a645ddd2a320", "name": "p1rdt6232", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7465d552-f9fd-4c18-bbcb-046e2214089f"}}}}, {"uuid": "a45aed2c-9785-4267-b6c9-93de8a2eb205", "name": "", "x": 38.59739040278303, "y": -122.53116220049235, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e39cb1db-d6a6-4b6c-bc73-920e0c34c292", "name": "p1rdt6028", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a45aed2c-9785-4267-b6c9-93de8a2eb205"}}}}, {"uuid": "47744c39-d0fa-4c6b-8dd3-2d10ae71edc2", "name": "", "x": 38.602431647117115, "y": -122.53503011701754, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f77960bf-f017-400c-b505-16e7c2e90fe7", "name": "p1rdt6028_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "47744c39-d0fa-4c6b-8dd3-2d10ae71edc2"}}}}, {"uuid": "73fddd2a-9c61-4c25-bfc8-9b3588a86e04", "name": "", "x": 38.597391979534734, "y": -122.52847857868831, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b3a83211-0829-4e2c-b618-3f1fcaba3e87", "name": "p1rdt8473", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "73fddd2a-9c61-4c25-bfc8-9b3588a86e04"}}}}, {"uuid": "d47488e2-6469-4439-a236-085f77265a79", "name": "", "x": 38.59407749157057, "y": -122.52505662658886, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c330731a-fd2c-40c7-8fce-94f7e17cf6d9", "name": "p1rdt8493lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d47488e2-6469-4439-a236-085f77265a79"}}}}, {"uuid": "c5d6d872-0cb7-44a4-8b2a-1680dd82e11e", "name": "", "x": 38.594091817303486, "y": -122.52510740253169, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ead37cb8-af1e-4a46-9466-6ff298b7f8b7", "name": "p1rlv18201", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c5d6d872-0cb7-44a4-8b2a-1680dd82e11e"}}}}, {"uuid": "d543b5e5-21eb-4d18-83f8-f17b77f46c83", "name": "", "x": 38.59405153241799, "y": -122.52501401155037, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cfb41891-7063-44b8-9286-1fe763e49924", "name": "p1rdt8493", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d543b5e5-21eb-4d18-83f8-f17b77f46c83"}}}}, {"uuid": "e2336c83-39fe-4b64-9b84-2eb2f4408be8", "name": "", "x": 38.6026030514407, "y": -122.53507494861152, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "409a29cf-ddd5-4031-92ca-db6cd2410704", "name": "p1rdt6028_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e2336c83-39fe-4b64-9b84-2eb2f4408be8"}}}}, {"uuid": "84a1a7b9-2f6d-432e-8a26-762b186fd77d", "name": "", "x": 38.67296456591668, "y": -122.57311952323086, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0921e58d-1ada-4556-8b01-8f22d3bf4ee2", "name": "p1rdt93lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "84a1a7b9-2f6d-432e-8a26-762b186fd77d"}}}}, {"uuid": "19391878-f7ac-418c-985a-d1d03bec6f38", "name": "", "x": 38.67288108818913, "y": -122.57387827884625, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3df778b4-e60b-4e17-b24b-67742d090f42", "name": "p1rlv183", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "19391878-f7ac-418c-985a-d1d03bec6f38"}}}}, {"uuid": "08de448b-f269-408e-8555-53810fe0aea3", "name": "", "x": 38.67284336560701, "y": -122.57341867755696, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d663fcdc-6c67-4bc9-99ed-12439f75804f", "name": "p1rlv204", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "08de448b-f269-408e-8555-53810fe0aea3"}}}}, {"uuid": "afc1a4c5-298c-454e-94d8-c72167c86521", "name": "", "x": 38.672896260917035, "y": -122.57309648596055, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2be21180-bfa8-4cd1-a3c5-68602896d657", "name": "p1rdm198", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "afc1a4c5-298c-454e-94d8-c72167c86521"}}}}, {"uuid": "f2445300-d709-40be-9352-addfc8d3546e", "name": "", "x": 38.67255503590974, "y": -122.57343188427429, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "90aa0d14-285a-4468-bbde-8d76f65b1780", "name": "p1rlv206", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f2445300-d709-40be-9352-addfc8d3546e"}}}}, {"uuid": "38a53f09-a685-40f7-b20c-a7170caea4fb", "name": "", "x": 38.67306781717814, "y": -122.57318743231879, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6a70fd02-3816-451f-a509-2ad767068eb4", "name": "p1rdm199", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "38a53f09-a685-40f7-b20c-a7170caea4fb"}}}}, {"uuid": "0c9426a0-9096-48e9-90ab-ad9746ad6f6f", "name": "", "x": 38.67309761817342, "y": -122.5739459691624, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6627102c-4524-4e69-bb4d-5b93226df412", "name": "p1rlv207", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0c9426a0-9096-48e9-90ab-ad9746ad6f6f"}}}}, {"uuid": "6210c740-6072-4fd5-8cb2-494c338084d5", "name": "", "x": 38.673202949412286, "y": -122.57317513422406, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6065e92f-dd89-4aeb-94af-173d81a49df1", "name": "p1rdm196", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6210c740-6072-4fd5-8cb2-494c338084d5"}}}}, {"uuid": "383df165-d455-44d1-aaa7-d9d026fa4bf3", "name": "", "x": 38.67319695527533, "y": -122.57400285874593, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "42ca8327-5dcc-415a-820c-ef6ec038b3d8", "name": "p1rlv184", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "383df165-d455-44d1-aaa7-d9d026fa4bf3"}}}}, {"uuid": "0fb5e2e8-91ff-4337-ae5c-5874c4a5a5b4", "name": "", "x": 38.6716242440999, "y": -122.57350240564409, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ef6be92d-5d1b-40e2-a2c2-9d0c1f0bf596", "name": "p1rdt99lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0fb5e2e8-91ff-4337-ae5c-5874c4a5a5b4"}}}}, {"uuid": "121accee-3c5d-4d8e-afbd-aa488401ee1b", "name": "", "x": 38.67172785280663, "y": -122.57395408806927, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33b6400e-c84e-43cf-b254-99f946e5a308", "name": "p1rlv190", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "121accee-3c5d-4d8e-afbd-aa488401ee1b"}}}}, {"uuid": "9ab562c3-fcf0-48cb-91a8-6a775a66e30e", "name": "", "x": 38.671562374281784, "y": -122.57305842624851, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "de2366e4-30da-429a-82b9-c0ef27eeab47", "name": "p1rlv202", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9ab562c3-fcf0-48cb-91a8-6a775a66e30e"}}}}, {"uuid": "371eadd3-a103-436e-b114-f0c24aaa1d57", "name": "", "x": 38.674085731551074, "y": -122.57304573384614, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1277a701-9fbd-4853-a809-962475e016c4", "name": "p1rdt101lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "371eadd3-a103-436e-b114-f0c24aaa1d57"}}}}, {"uuid": "11a58949-2b98-49be-b558-d21e2a7bea41", "name": "", "x": 38.674164000252716, "y": -122.57229574382116, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "84223c1b-69e4-4ebc-8274-8706bb412780", "name": "p1rlv193", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "11a58949-2b98-49be-b558-d21e2a7bea41"}}}}, {"uuid": "3042c514-d9a7-4cbf-b292-08e4f7e3bf5f", "name": "", "x": 38.673326264900375, "y": -122.57317042703883, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3aa8d6f2-8d84-42d6-8e7b-89e3b1efa03c", "name": "p1rdt108lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3042c514-d9a7-4cbf-b292-08e4f7e3bf5f"}}}}, {"uuid": "fba9d52a-56da-4743-9f43-d8e41e614e35", "name": "", "x": 38.673338794652196, "y": -122.57335825878279, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a982feac-5730-4fe0-a1b8-25c06b36e3b0", "name": "p1rlv212", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fba9d52a-56da-4743-9f43-d8e41e614e35"}}}}, {"uuid": "6f53652c-c937-430f-839f-ab69e81b2b63", "name": "", "x": 38.661367233687706, "y": -122.56984548041399, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "448cc5e0-391f-4a6b-8199-25cef4593edf", "name": "p1rdt6121lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6f53652c-c937-430f-839f-ab69e81b2b63"}}}}, {"uuid": "489d0901-4beb-4fa1-98a8-56a8df5765df", "name": "", "x": 38.66161605427373, "y": -122.56888775894382, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "163c3824-6847-4b94-9e81-08f15f4667a1", "name": "p1rlv12687", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "489d0901-4beb-4fa1-98a8-56a8df5765df"}}}}, {"uuid": "18b06d68-ca94-4d75-b53f-e26986e76248", "name": "", "x": 38.66221308963423, "y": -122.56844471302269, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e81ba94-5857-42e4-aeee-58542cef0fb6", "name": "p1rdt6123lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "18b06d68-ca94-4d75-b53f-e26986e76248"}}}}, {"uuid": "5ab40600-e462-49b4-a6e1-97fcebd2e9c8", "name": "", "x": 38.662187146256294, "y": -122.5684020420726, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ff16aad0-98c1-4563-a844-e0ce909c1a79", "name": "p1rlv12713", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ab40600-e462-49b4-a6e1-97fcebd2e9c8"}}}}, {"uuid": "48892e13-368b-44ee-824c-fa7c114949e5", "name": "", "x": 38.666474403379304, "y": -122.59876007752939, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8428de0e-4b06-4f19-bffb-5fed32f96f67", "name": "p1rdt8017lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "48892e13-368b-44ee-824c-fa7c114949e5"}}}}, {"uuid": "4417ff6d-d2ea-4fe9-88cb-de12f1a6ab25", "name": "", "x": 38.666431086206416, "y": -122.59829258598047, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b53edd15-5a3e-4b7a-97c4-046582bb4801", "name": "p1rlv17006", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4417ff6d-d2ea-4fe9-88cb-de12f1a6ab25"}}}}, {"uuid": "308b380d-d41b-45f3-96de-9e617604886e", "name": "", "x": 38.66353413238862, "y": -122.60568928818653, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a367e687-b29a-44b4-a943-7b94762e549e", "name": "p1rdt8043lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "308b380d-d41b-45f3-96de-9e617604886e"}}}}, {"uuid": "08f15de6-260e-419d-911e-b628e755ff37", "name": "", "x": 38.6635082025271, "y": -122.60564660289965, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8ff9eb4c-2523-48e0-8490-619d26b9cca4", "name": "p1rlv17103", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "08f15de6-260e-419d-911e-b628e755ff37"}}}}, {"uuid": "3f5eea31-80ca-4830-9a4c-66869b9db1a5", "name": "", "x": 38.656285239065134, "y": -122.61480721656375, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8bb025c5-31eb-4771-b433-e1dcad03b3ed", "name": "p1rdt8065lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3f5eea31-80ca-4830-9a4c-66869b9db1a5"}}}}, {"uuid": "c7d84cbf-8e4a-40fa-948c-a37206aa3f12", "name": "", "x": 38.65636014038154, "y": -122.61479929639421, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3c6c52e-cf93-467a-a303-94b96b33a3da", "name": "p1rlv17155", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c7d84cbf-8e4a-40fa-948c-a37206aa3f12"}}}}, {"uuid": "57105b01-9e4d-457c-a82e-90b19eb89a1a", "name": "", "x": 38.65653706419615, "y": -122.61653379624518, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "62e77e46-bf33-474f-907b-81d36aae8975", "name": "p1rdm17752", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "57105b01-9e4d-457c-a82e-90b19eb89a1a"}}}}, {"uuid": "59295e4b-87ad-415c-8961-0244dffcbade", "name": "", "x": 38.656142018437656, "y": -122.61698412819987, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "041caa30-2985-44ca-8013-e11a9bda7dff", "name": "p1rlv17164", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59295e4b-87ad-415c-8961-0244dffcbade"}}}}, {"uuid": "73d19644-a33b-400d-bc6c-0b09086220d9", "name": "", "x": 38.65646182364152, "y": -122.61643827928047, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dd01eed6-0e70-42e7-ac29-4bfd2f70366a", "name": "p1rdt8068lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "73d19644-a33b-400d-bc6c-0b09086220d9"}}}}, {"uuid": "e8387e72-4704-4ccd-ba30-31f1bae60656", "name": "", "x": 38.6564643300682, "y": -122.61633880273914, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "46b5c5bc-6738-4520-b98c-32bd43f4c91c", "name": "p1rdm17753", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e8387e72-4704-4ccd-ba30-31f1bae60656"}}}}, {"uuid": "04a61433-ab27-4c19-8d09-b9a8f24e0620", "name": "", "x": 38.65583419030237, "y": -122.6165490366375, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5768eaca-abe3-4347-af78-02b50ec6f2a9", "name": "p1rlv17199", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "04a61433-ab27-4c19-8d09-b9a8f24e0620"}}}}, {"uuid": "e26f0031-1622-4dc5-844f-d31e2652eff3", "name": "", "x": 38.656487161757404, "y": -122.6159209581833, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d0bcd460-ccf2-42ee-83c6-bada397ab4d6", "name": "p1rdt8070lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e26f0031-1622-4dc5-844f-d31e2652eff3"}}}}, {"uuid": "ddb8eca2-3f6e-48b5-9bd6-8b8c916885cf", "name": "", "x": 38.65609360641926, "y": -122.61596151268897, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2b4e44ab-e644-4e48-b1b2-82dc15d38d17", "name": "p1rlv17167", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ddb8eca2-3f6e-48b5-9bd6-8b8c916885cf"}}}}, {"uuid": "5d80fb83-4c57-405b-be79-fefbfe9f0f29", "name": "", "x": 38.66692113690325, "y": -122.58783715855819, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f21f4e99-8877-4bb0-9956-9240bc6db3d1", "name": "p1rdt8190lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5d80fb83-4c57-405b-be79-fefbfe9f0f29"}}}}, {"uuid": "0ec4963f-c030-40aa-8f4c-bf6e68b00d71", "name": "", "x": 38.66724289358908, "y": -122.58733754347764, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8c9970ae-e914-407d-8222-12c08638a854", "name": "p1rlv17376", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0ec4963f-c030-40aa-8f4c-bf6e68b00d71"}}}}, {"uuid": "d61466da-7b42-4518-90f7-f4815488ce05", "name": "", "x": 38.664369444812806, "y": -122.58690973341812, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d12bf6fb-8dac-4729-bcda-1ee61c63f6e8", "name": "p1rdt8204lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d61466da-7b42-4518-90f7-f4815488ce05"}}}}, {"uuid": "0a451f8e-953d-4a4d-8347-edad82693b2c", "name": "", "x": 38.66416826088575, "y": -122.58688392637725, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dc7fa312-1baf-4f23-925f-a281071183a6", "name": "p1rlv17402", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a451f8e-953d-4a4d-8347-edad82693b2c"}}}}, {"uuid": "4b26802d-e23c-4468-b2c3-580cea831428", "name": "", "x": 38.6664926486277, "y": -122.58749879976138, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ecf11723-eb6d-423c-ac0c-85fa2d1ba846", "name": "p1rdt8208lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4b26802d-e23c-4468-b2c3-580cea831428"}}}}, {"uuid": "4ac2c5c1-618e-4106-b26e-5c3773bf4c79", "name": "", "x": 38.666718636185976, "y": -122.58689226135496, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f147f7e5-33e8-430b-9822-715e772debb3", "name": "p1rlv17413", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ac2c5c1-618e-4106-b26e-5c3773bf4c79"}}}}, {"uuid": "f901d18c-7e76-4de4-83f3-504b150840d2", "name": "", "x": 38.6508349878355, "y": -122.52772270990391, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f1a593e3-4735-47d2-b893-dd2d07c3c47c", "name": "p1rdt8578lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f901d18c-7e76-4de4-83f3-504b150840d2"}}}}, {"uuid": "fa2bab8c-4741-4c89-a36e-0f401dc5f8f6", "name": "", "x": 38.6509409741122, "y": -122.52789042198899, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5a28b095-45f5-43ec-983b-c1de596d4cb5", "name": "p1rlv18362", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa2bab8c-4741-4c89-a36e-0f401dc5f8f6"}}}}, {"uuid": "54e5f769-3d1c-4b01-8a58-c3530ce25014", "name": "", "x": 38.65066839894964, "y": -122.52734059189255, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8d1c3d0a-9def-4516-8429-386f1d70f506", "name": "p1rlv18364", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "54e5f769-3d1c-4b01-8a58-c3530ce25014"}}}}, {"uuid": "3d133081-f320-481d-93db-a3b5dcc28d51", "name": "", "x": 38.650824008938194, "y": -122.52793715797524, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "408c825d-17ac-4aea-9fc7-fff420657fc7", "name": "p1rlv18367", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3d133081-f320-481d-93db-a3b5dcc28d51"}}}}, {"uuid": "fa1ac5d2-b7cb-453b-9242-5ea28ea7b3ab", "name": "", "x": 38.647860789632105, "y": -122.5254589040337, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "134bac3d-5b7e-48d7-950e-01e5b7d43852", "name": "p1rdt8583lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa1ac5d2-b7cb-453b-9242-5ea28ea7b3ab"}}}}, {"uuid": "d536c44b-825c-4165-812f-b5fa407dad21", "name": "", "x": 38.64817724906055, "y": -122.52638016767358, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "905e171c-13d7-4f8d-b88a-7501b2327d81", "name": "p1rlv18370", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d536c44b-825c-4165-812f-b5fa407dad21"}}}}, {"uuid": "a6f0e76a-a551-45f5-a544-955ccc0eb60d", "name": "", "x": 38.64706546256806, "y": -122.5262571069094, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a8ba1042-fcfd-47a8-aa0f-8b13618d3212", "name": "p1rdt8584lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a6f0e76a-a551-45f5-a544-955ccc0eb60d"}}}}, {"uuid": "7891f0b1-efd2-44fb-9612-2be3e5dd1ef6", "name": "", "x": 38.64750833323082, "y": -122.52657595427343, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "58792e8c-3ad9-45bb-ac47-01983cca2a2b", "name": "p1rlv18371", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7891f0b1-efd2-44fb-9612-2be3e5dd1ef6"}}}}, {"uuid": "ee4e0a8b-2d46-4187-a857-a2e71a918ff8", "name": "", "x": 38.66789379909343, "y": -122.62737431712556, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c8f14e6e-ee96-4ae9-86ba-4a07cf103b65", "name": "p1rdt10491lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ee4e0a8b-2d46-4187-a857-a2e71a918ff8"}}}}, {"uuid": "2655db2b-f896-45ca-817d-dba842af8f70", "name": "", "x": 38.66785523664377, "y": -122.62747399595972, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a86348e4-7573-4903-b223-90155579923e", "name": "p1rlv22745", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2655db2b-f896-45ca-817d-dba842af8f70"}}}}, {"uuid": "3acca42a-228d-405c-b242-24b9b408046c", "name": "", "x": 38.66771072023337, "y": -122.6273712914315, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ee8b6bab-9edd-4250-b57b-3a76b432fb54", "name": "p1rdm23269", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3acca42a-228d-405c-b242-24b9b408046c"}}}}, {"uuid": "e82104cd-1fd3-4a40-84ae-355f99fe8c59", "name": "", "x": 38.66773801158078, "y": -122.62745161373962, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "db05b7f0-d2a8-4876-876e-ef0e9b469580", "name": "p1rlv22758", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e82104cd-1fd3-4a40-84ae-355f99fe8c59"}}}}, {"uuid": "5b6968d5-f9b5-4ee7-adba-3b83bc1f93d0", "name": "", "x": 38.656528899791525, "y": -122.61592868327206, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "473520c7-0098-4bc2-a46f-07efd6c3759c", "name": "p1rdt8070", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5b6968d5-f9b5-4ee7-adba-3b83bc1f93d0"}}}}, {"uuid": "7bb0f297-562b-497d-b9ce-36499e5b1011", "name": "", "x": 38.6563269771708, "y": -122.61481494098487, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "862f3566-9443-4b82-8f05-c994581e131a", "name": "p1rdt8065", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7bb0f297-562b-497d-b9ce-36499e5b1011"}}}}, {"uuid": "5b97a273-c1db-4cad-ba97-ea0ec4645596", "name": "", "x": 38.65650356164319, "y": -122.61644600466717, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7f5fbb8b-0c32-4aa7-acaf-7ea2b5e56505", "name": "p1rdt8068", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5b97a273-c1db-4cad-ba97-ea0ec4645596"}}}}, {"uuid": "3e57a0ea-ffba-40e1-804e-eaa3a7897315", "name": "", "x": 38.663548423315845, "y": -122.60574012937602, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "691c1909-3b71-4e07-abf0-95aaabfa23bb", "name": "p1rdt8043", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e57a0ea-ffba-40e1-804e-eaa3a7897315"}}}}, {"uuid": "ed6aebf5-9450-4578-881d-cae98151a49d", "name": "", "x": 38.65907117917629, "y": -122.61161258790305, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cbafbe81-1649-4bae-b9af-c4b1757392f0", "name": "p1rdt8043-p1rdt8070x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ed6aebf5-9450-4578-881d-cae98151a49d"}}}}, {"uuid": "6c8fea95-a7aa-4e43-ab48-30f65042e891", "name": "", "x": 38.66743589391774, "y": -122.62597035336422, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ca19324f-0855-4633-be68-b16c872e196d", "name": "p1rdt10491-p1rdt8043x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c8fea95-a7aa-4e43-ab48-30f65042e891"}}}}, {"uuid": "99689df4-980e-4bb2-b002-ae9a37ffd539", "name": "", "x": 38.667852061856834, "y": -122.62736658421983, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4737e613-8cf5-45d7-a3f5-71af051ece4c", "name": "p1rdt10491", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "99689df4-980e-4bb2-b002-ae9a37ffd539"}}}}, {"uuid": "6499ec0f-5e4c-4c55-9d87-b9feec61c306", "name": "", "x": 38.666432664329825, "y": -122.59875236139737, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6378abd-969e-4ec8-93eb-2cc39cdb18eb", "name": "p1rdt8017", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6499ec0f-5e4c-4c55-9d87-b9feec61c306"}}}}, {"uuid": "f8c35a56-8487-4552-91de-996ae7e93a21", "name": "", "x": 38.665466700320124, "y": -122.60006059980222, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "feda8d99-6fae-4c6e-bf52-f87894687da5", "name": "p1rdt8017-p1rdt8043x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f8c35a56-8487-4552-91de-996ae7e93a21"}}}}, {"uuid": "b47e2761-7265-4eda-9f5e-916e5198314b", "name": "", "x": 38.67412513347839, "y": -122.57295162842586, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a09cdbca-4e7b-4d9a-b479-515074964171", "name": "p1rdt101-p1rdt8017x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b47e2761-7265-4eda-9f5e-916e5198314b"}}}}, {"uuid": "0d8f64aa-a831-414b-b33d-90920ccc73f2", "name": "", "x": 38.67372843812363, "y": -122.57642531522278, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b1aeba4b-536e-4067-a7a5-627470ae0711", "name": "p1rdt101-p1rdt8017xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0d8f64aa-a831-414b-b33d-90920ccc73f2"}}}}, {"uuid": "cb64d0c5-316b-4ef4-9fc4-06dc369727d9", "name": "", "x": 38.6667923442126, "y": -122.59769681955328, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8c1a4365-a594-48be-b138-aa6935c34481", "name": "p1rdt101-p1rdt8017xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb64d0c5-316b-4ef4-9fc4-06dc369727d9"}}}}, {"uuid": "6b0aaced-0cdb-4e3b-9ab8-ec56496f99ba", "name": "", "x": 38.67336800550842, "y": -122.57317812900477, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e61ce952-a643-45aa-a466-8aa15ecceb48", "name": "p1rdt108", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6b0aaced-0cdb-4e3b-9ab8-ec56496f99ba"}}}}, {"uuid": "cc9a67b6-79b9-4193-be24-d3b00a83c29d", "name": "", "x": 38.67409957836356, "y": -122.57299468560076, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2d8e5d83-cd9c-4527-9eef-6219c98dfe93", "name": "p1rdt101", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc9a67b6-79b9-4193-be24-d3b00a83c29d"}}}}, {"uuid": "cbcc0bc7-f2c6-4318-8fe8-f233849842d7", "name": "", "x": 38.673004812616185, "y": -122.57321304352497, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a4f100ee-0152-4e27-bf0e-2c7dea1537ad", "name": "p1rdt108-p1rdt93x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cbcc0bc7-f2c6-4318-8fe8-f233849842d7"}}}}, {"uuid": "80f718dd-80a7-4d45-98b2-65163070d903", "name": "", "x": 38.66653438838322, "y": -122.58750650935949, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8e2b4d77-2388-4897-86fe-06409fa9d222", "name": "p1rdt8208", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "80f718dd-80a7-4d45-98b2-65163070d903"}}}}, {"uuid": "c15f08e7-d9f7-403e-a6d8-3b883874c9fc", "name": "", "x": 38.6643277050057, "y": -122.58690202438763, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fa2342e6-2d40-424a-830c-a84af4632b6e", "name": "p1rdt8204", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c15f08e7-d9f7-403e-a6d8-3b883874c9fc"}}}}, {"uuid": "914c9442-7ee2-4f65-83b0-5589227565a3", "name": "", "x": 38.66696287663581, "y": -122.58784486869551, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0a761aef-a766-40e2-b8d7-e5a918cece18", "name": "p1rdt8190", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "914c9442-7ee2-4f65-83b0-5589227565a3"}}}}, {"uuid": "2b710d2f-ba85-48eb-b045-0a1e53513481", "name": "", "x": 38.66701682299843, "y": -122.58779500809689, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b860d5c-43e4-429e-b945-378020e3f926", "name": "p1rdt8190-p1rdt99xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2b710d2f-ba85-48eb-b045-0a1e53513481"}}}}, {"uuid": "45f324c1-53a0-4c45-84bb-8247a59540a3", "name": "", "x": 38.67081351738392, "y": -122.57529296188245, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6be75535-8c32-47ea-bad5-986daaed0921", "name": "p1rdt8190-p1rdt99x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "45f324c1-53a0-4c45-84bb-8247a59540a3"}}}}, {"uuid": "bd0ae6f7-68ed-42de-91dc-6e78b005e83b", "name": "", "x": 38.661326984313604, "y": -122.56975197710662, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ddf8f344-dcca-418d-850e-745f18d29660", "name": "p1rdt6121-p1rdt6123x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bd0ae6f7-68ed-42de-91dc-6e78b005e83b"}}}}, {"uuid": "1062a7cd-f594-4e16-9327-1fee2a297714", "name": "", "x": 38.6622273967057, "y": -122.56849554572818, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "17f807ba-6ad6-4fd9-9dd0-2c0bacea5b24", "name": "p1rdt6123", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1062a7cd-f594-4e16-9327-1fee2a297714"}}}}, {"uuid": "b1a6adaf-4169-404d-815c-821d17c42c72", "name": "", "x": 38.64782050495066, "y": -122.52536544340624, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d0747505-3381-4df0-a86e-3859acac8496", "name": "p1rdt8583-p1rdt8584x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b1a6adaf-4169-404d-815c-821d17c42c72"}}}}, {"uuid": "6fe736f3-597d-4832-a078-7f9462c6089a", "name": "", "x": 38.64710720626507, "y": -122.52626477895555, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2b601580-3091-4d8c-9718-1367c7ed385f", "name": "p1rdt8584", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6fe736f3-597d-4832-a078-7f9462c6089a"}}}}, {"uuid": "b74c66f5-7370-4363-aadb-c2963556dbbb", "name": "", "x": 38.67166598469829, "y": -122.57351010762986, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "092a9d51-a39c-4c05-905e-93fb1ae96ba2", "name": "p1rdt99", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b74c66f5-7370-4363-aadb-c2963556dbbb"}}}}, {"uuid": "c251ee2b-6d25-444e-84ed-7a550939f36b", "name": "", "x": 38.671869985546934, "y": -122.57338996774229, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e3d15ce6-878d-4dd5-bb33-5a0f6c11dded", "name": "p1rdt93-p1rdt99x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c251ee2b-6d25-444e-84ed-7a550939f36b"}}}}, {"uuid": "3c977c81-252d-4ac1-99d0-aac8f9743cbc", "name": "", "x": 38.67299050757224, "y": -122.5731622022605, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "900d49ce-4834-4f99-8d74-a5e9d2f63ea0", "name": "p1rdt93", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3c977c81-252d-4ac1-99d0-aac8f9743cbc"}}}}, {"uuid": "2bd1ce4a-a2d6-48af-9731-0ffbbac3c303", "name": "", "x": 38.66135292720275, "y": -122.56979464804087, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2390c014-d418-4d63-8438-529a036487db", "name": "p1rdt6121", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2bd1ce4a-a2d6-48af-9731-0ffbbac3c303"}}}}, {"uuid": "c7db02d4-5bc2-4f36-97d1-dfc8a8bdabb6", "name": "", "x": 38.66910358694126, "y": -122.57345236501213, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "49c9e6df-3490-4df1-88a0-8a83ca6cdd1e", "name": "p1rdt6121-p1rdt99x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c7db02d4-5bc2-4f36-97d1-dfc8a8bdabb6"}}}}, {"uuid": "697424df-cd5f-4975-84bb-60f564edf569", "name": "", "x": 38.650793244252796, "y": -122.52771503663553, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bb866499-9e9c-4394-bd76-d4320ba4934b", "name": "p1rdt8578", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "697424df-cd5f-4975-84bb-60f564edf569"}}}}, {"uuid": "35989896-71ba-4201-91dc-e454d727ee91", "name": "", "x": 38.660311758411375, "y": -122.56710257404733, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "af229e5c-a70f-4354-bddc-4a2698802741", "name": "p1rdt6121-p1rdt8578x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "35989896-71ba-4201-91dc-e454d727ee91"}}}}, {"uuid": "939671ba-5e71-4c33-a5b6-6ae2212229dc", "name": "", "x": 38.64784646411654, "y": -122.52540809020192, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dbb79e10-21ba-4f04-b8a3-0cf711d26d40", "name": "p1rdt8583", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "939671ba-5e71-4c33-a5b6-6ae2212229dc"}}}}, {"uuid": "1d950e8d-70ee-4f99-a69a-f6c10714f0b3", "name": "", "x": 38.648598745729544, "y": -122.52587175663075, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "975237e9-bd83-4a30-83ab-221eb7f85c65", "name": "p1rdt8578-p1rdt8583x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d950e8d-70ee-4f99-a69a-f6c10714f0b3"}}}}, {"uuid": "614fdcef-422b-4210-b725-39f50e5db0bf", "name": "635840a4-7200-4618-8afc-99b9529d4031_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_voltagesource_equipment", "type": "PhaseVoltageSourceEquipment", "serialized_type": "base"}}, "r0": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Resistance", "serialized_type": "quantity"}}}, "r1": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Resistance", "serialized_type": "quantity"}}}, "x0": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Reactance", "serialized_type": "quantity"}}}, "x1": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Reactance", "serialized_type": "quantity"}}}, "voltage": {"value": 39.838337182448036, "units": "kilovolt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "angle": {"value": 0.0, "units": "degree", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Angle", "serialized_type": "quantity"}}}}, {"uuid": "14c8c055-5866-4494-860e-192d157bb809", "name": "635840a4-7200-4618-8afc-99b9529d4031_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_voltagesource_equipment", "type": "PhaseVoltageSourceEquipment", "serialized_type": "base"}}, "r0": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Resistance", "serialized_type": "quantity"}}}, "r1": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Resistance", "serialized_type": "quantity"}}}, "x0": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Reactance", "serialized_type": "quantity"}}}, "x1": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Reactance", "serialized_type": "quantity"}}}, "voltage": {"value": 39.838337182448036, "units": "kilovolt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "angle": {"value": 120.0, "units": "degree", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Angle", "serialized_type": "quantity"}}}}, {"uuid": "00dfcdee-b9ee-489c-a339-b4615d17c496", "name": "635840a4-7200-4618-8afc-99b9529d4031_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_voltagesource_equipment", "type": "PhaseVoltageSourceEquipment", "serialized_type": "base"}}, "r0": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Resistance", "serialized_type": "quantity"}}}, "r1": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Resistance", "serialized_type": "quantity"}}}, "x0": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Reactance", "serialized_type": "quantity"}}}, "x1": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Reactance", "serialized_type": "quantity"}}}, "voltage": {"value": 39.838337182448036, "units": "kilovolt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "angle": {"value": 240.0, "units": "degree", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Angle", "serialized_type": "quantity"}}}}, {"uuid": "ff5789ac-35ae-461f-8d88-cd7b58b34ab3", "name": "635840a4-7200-4618-8afc-99b9529d4031", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.voltagesource_equipment", "type": "VoltageSourceEquipment", "serialized_type": "base"}}, "sources": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_voltagesource_equipment", "type": "PhaseVoltageSourceEquipment", "serialized_type": "composed_component", "uuid": "614fdcef-422b-4210-b725-39f50e5db0bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_voltagesource_equipment", "type": "PhaseVoltageSourceEquipment", "serialized_type": "composed_component", "uuid": "14c8c055-5866-4494-860e-192d157bb809"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_voltagesource_equipment", "type": "PhaseVoltageSourceEquipment", "serialized_type": "composed_component", "uuid": "00dfcdee-b9ee-489c-a339-b4615d17c496"}}}]}, {"uuid": "267037ac-94da-4162-9484-f2f5d9cab688", "name": "source", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_vsource", "type": "DistributionVoltageSource", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "574ab810-c1b0-4662-8c4d-f32ab6893a36"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.voltagesource_equipment", "type": "VoltageSourceEquipment", "serialized_type": "composed_component", "uuid": "ff5789ac-35ae-461f-8d88-cd7b58b34ab3"}}}}, {"uuid": "e5469e34-b4db-4115-9139-ffc60bb49bbd", "name": "546d6ea1-cd18-4228-8edd-9598526a92df_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.840334051658807, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.3948056193408553, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "67309e73-810a-4c78-8158-ce7710efe7e3", "name": "0de45f54-cece-4e94-844c-81772bee923e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e5469e34-b4db-4115-9139-ffc60bb49bbd"}}}]}, {"uuid": "d8d6bc4a-d96f-43ae-bc69-823255ae76bd", "name": "load_p1rlv10170_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02e86824-b793-4080-9401-c6995a365baf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "67309e73-810a-4c78-8158-ce7710efe7e3"}}}}, {"uuid": "20c0e7c7-8721-449c-8c78-09d4f3da035a", "name": "8ee826d6-19c9-4320-b5fa-c5423073ad16_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.840334051658807, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.3948056193408553, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4b2bfcd5-d8c2-4fcf-a9ef-c821a2fc7a47", "name": "7cd431cb-01ba-4354-b594-83a35144906b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "20c0e7c7-8721-449c-8c78-09d4f3da035a"}}}]}, {"uuid": "4299a3aa-ba1d-4f0a-832e-e4ee9347ae96", "name": "load_p1rlv10170_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02e86824-b793-4080-9401-c6995a365baf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4b2bfcd5-d8c2-4fcf-a9ef-c821a2fc7a47"}}}}, {"uuid": "129db834-e664-434f-8575-b55557c4d16d", "name": "3159695e-34c3-44b2-99ac-8f94ad58ec5f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5675771284059596, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.814222257775612, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1fa7a333-c682-4f9f-b838-214a1d8e9d1c", "name": "1c0a9cd1-4dfa-42e3-9507-6749ffbb8be3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "129db834-e664-434f-8575-b55557c4d16d"}}}]}, {"uuid": "b92a9605-b0ce-432e-98e8-89764b805b42", "name": "load_p1rlv10189_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58f2b2c3-4f6f-4fd2-abb9-42ff665692bd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1fa7a333-c682-4f9f-b838-214a1d8e9d1c"}}}}, {"uuid": "3b57b23f-b611-422d-8dfb-191cdc583f6f", "name": "0d6e89aa-c113-496d-b3b7-27aaa1bc6294_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5675771284059596, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.814222257775612, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5ed83898-2733-4cea-a50f-5d2f64738b3f", "name": "45b095f5-c1e1-4fd2-9c6f-b5c6cbd9d6fe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3b57b23f-b611-422d-8dfb-191cdc583f6f"}}}]}, {"uuid": "18684a60-bdcf-4ecb-b451-206191b5b387", "name": "load_p1rlv10189_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58f2b2c3-4f6f-4fd2-abb9-42ff665692bd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5ed83898-2733-4cea-a50f-5d2f64738b3f"}}}}, {"uuid": "b50974d8-7716-4e1f-a154-58141fe96159", "name": "07638998-4261-4040-9283-9a1ceeb6a17a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2859398622891502, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31064660144885853, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8262d88d-f6d6-4195-84e4-1ef29d502f23", "name": "c5ca30e9-1a76-466f-8aac-a8ac6cca0e2a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b50974d8-7716-4e1f-a154-58141fe96159"}}}]}, {"uuid": "f0b7de95-2441-47ba-b581-d2b2deff0a7c", "name": "load_p1rlv10262_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3317d7c2-2588-426d-91fc-3d765b932da6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8262d88d-f6d6-4195-84e4-1ef29d502f23"}}}}, {"uuid": "8a589d2d-8bb5-4a2d-a783-bae8c6be7f51", "name": "53619472-8b4a-4e99-8f1e-373fe1c283b8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2859398622891502, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31064660144885853, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d1078032-48da-45a9-9514-1bd009f80425", "name": "cae9ace2-76c6-4edb-a648-864e751d71b3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a589d2d-8bb5-4a2d-a783-bae8c6be7f51"}}}]}, {"uuid": "bd031773-5a92-44a8-b655-5ce11b5a4e7b", "name": "load_p1rlv10262_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3317d7c2-2588-426d-91fc-3d765b932da6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d1078032-48da-45a9-9514-1bd009f80425"}}}}, {"uuid": "993432e9-66d3-4fc9-affe-9f6530caeac7", "name": "91274f2d-6b69-4a31-922c-34d0fd405697_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.598111299087247, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3022070914124596, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5c9059e0-2b4a-4ed3-8029-709216e1ff3f", "name": "ee60a67d-83a4-4707-a5ce-a17eb9457a3b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "993432e9-66d3-4fc9-affe-9f6530caeac7"}}}]}, {"uuid": "efed8560-d920-49e0-8ae6-7fa50af9ebef", "name": "load_p1rlv10491_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f7116b9-96c1-42c8-850f-7787f5fd0f96"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5c9059e0-2b4a-4ed3-8029-709216e1ff3f"}}}}, {"uuid": "804be5d0-f940-44d3-87a2-1666ca6bfd99", "name": "8472f830-52fe-4e78-8f35-3650a707dfc3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.598111299087247, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3022070914124596, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e15b851c-dbf3-403b-9ce4-125e3739f110", "name": "5ae5f7ac-f7e3-44c4-81ed-2fd9c6cc7ceb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "804be5d0-f940-44d3-87a2-1666ca6bfd99"}}}]}, {"uuid": "c9f4b35b-fff0-42fe-9c01-70fec1a715f5", "name": "load_p1rlv10491_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f7116b9-96c1-42c8-850f-7787f5fd0f96"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e15b851c-dbf3-403b-9ce4-125e3739f110"}}}}, {"uuid": "2335485c-19cd-4605-9529-64275bc82eb0", "name": "a7ad5af2-a876-40d2-be51-500cc561015e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.388743979084916, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.03502268140121, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "867db88d-63b7-4bee-905f-784adcb5e721", "name": "3ef95a16-ca14-44b8-8a43-40eb5ab8cc7c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2335485c-19cd-4605-9529-64275bc82eb0"}}}]}, {"uuid": "0dc080b9-936f-4c3a-8e91-4be50f2719d3", "name": "load_p1rlv10521_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31f26b28-fc9d-4b3d-b204-cf40f3478c44"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "867db88d-63b7-4bee-905f-784adcb5e721"}}}}, {"uuid": "8418f1e2-1166-44ca-93f2-2f746cabc291", "name": "d8b85703-88cb-4147-9b12-71cc788bb321_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.388743979084916, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.03502268140121, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aa1ebe23-a640-41b4-bf0e-695a31d0e2b9", "name": "b4b52ff8-feab-429c-bfa7-67cfc1e912a9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8418f1e2-1166-44ca-93f2-2f746cabc291"}}}]}, {"uuid": "88b9c328-7f31-4d26-a036-a54f56ce234b", "name": "load_p1rlv10521_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31f26b28-fc9d-4b3d-b204-cf40f3478c44"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aa1ebe23-a640-41b4-bf0e-695a31d0e2b9"}}}}, {"uuid": "8c834a48-84b5-4861-bb74-d75985b72713", "name": "5d0dc6e4-fbab-47f9-8a91-231f6c1cdacb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0052757727111112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4127143879372469, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "88c22e57-29b7-47d0-b622-ffe83d964647", "name": "0ccc4eb5-9755-4d5f-a364-0f965120d933", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8c834a48-84b5-4861-bb74-d75985b72713"}}}]}, {"uuid": "9af6766f-1fd9-4825-a24d-8626cd72f11f", "name": "load_p1rlv10523_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35d47036-a044-4c67-b5b5-0006e2a3b68e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "88c22e57-29b7-47d0-b622-ffe83d964647"}}}}, {"uuid": "8e2f3d41-662e-4980-a1b7-c7fb900caf45", "name": "6647fe10-6588-4164-9eb3-fea25d2a9462_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0052757727111112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4127143879372469, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b8189c3a-08fd-4911-a1b5-f0955e23a3a3", "name": "cb7b10a1-ef90-490e-a741-057dbb9d5a98", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8e2f3d41-662e-4980-a1b7-c7fb900caf45"}}}]}, {"uuid": "5d074c7c-783a-49b5-bbf6-863562eb73a0", "name": "load_p1rlv10523_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35d47036-a044-4c67-b5b5-0006e2a3b68e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b8189c3a-08fd-4911-a1b5-f0955e23a3a3"}}}}, {"uuid": "61dccb8d-ca08-485b-a85d-1ddcd11916ad", "name": "88a2a0b3-fce5-4f48-bfa4-7b1781a741ff_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.346612792133217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8934968317135462, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0338a4f1-fc36-4a79-8794-79a666eb2c08", "name": "fa4c633e-4531-48d1-a321-07ff0c9e763c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "61dccb8d-ca08-485b-a85d-1ddcd11916ad"}}}]}, {"uuid": "92703db3-7c03-43fd-ad1e-f9cfeba4b985", "name": "load_p1rlv10538_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a302271d-4cf3-45ff-9308-b9cf31fbefa3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0338a4f1-fc36-4a79-8794-79a666eb2c08"}}}}, {"uuid": "98bcc0db-9132-4a3c-b610-06c2a350389a", "name": "325c85da-bcf2-4095-a07b-f0d830768108_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.346612792133217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8934968317135462, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ca6b885e-c8f9-4c05-959a-8d15c50227f0", "name": "d67af9d6-ac8e-411c-9161-2fdf6f6679fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "98bcc0db-9132-4a3c-b610-06c2a350389a"}}}]}, {"uuid": "b731739f-fa18-4fad-905c-87443cfce5d5", "name": "load_p1rlv10538_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a302271d-4cf3-45ff-9308-b9cf31fbefa3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ca6b885e-c8f9-4c05-959a-8d15c50227f0"}}}}, {"uuid": "6163aa2a-d4cd-4dfd-ad54-185653ab500b", "name": "561cc921-b931-499a-9b8b-b842a3b37e3b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.732212626630997, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.8695385943463294, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a968d13-c9e7-46a9-91eb-97e0d61a66b4", "name": "561cc921-b931-499a-9b8b-b842a3b37e3b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.732212626630997, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.8695385943463294, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "265d3447-d136-4cd0-89e8-91663f91a7fb", "name": "561cc921-b931-499a-9b8b-b842a3b37e3b_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.732212626630997, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.8695385943463294, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ce4815e4-79ce-4a08-8a1b-ea8a864d4c9b", "name": "1d264e18-a308-48d9-8e38-d4620f923977", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6163aa2a-d4cd-4dfd-ad54-185653ab500b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0a968d13-c9e7-46a9-91eb-97e0d61a66b4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "265d3447-d136-4cd0-89e8-91663f91a7fb"}}}]}, {"uuid": "5a1b9a31-aa33-4417-9163-777f1be8b93c", "name": "load_p1rlv10539", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08331744-08b7-455e-b2ca-284cae95fb06"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ce4815e4-79ce-4a08-8a1b-ea8a864d4c9b"}}}}, {"uuid": "4acb4341-939b-4101-99e7-6eabbbfe10dc", "name": "1b203d67-d092-48e6-9fdd-033bd70091ff_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3798783675992279, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6151141774255103, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "029b3287-e402-41d2-ba35-dc675176b103", "name": "16e47c63-28f8-404d-af33-fb21391635d6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4acb4341-939b-4101-99e7-6eabbbfe10dc"}}}]}, {"uuid": "02684642-c54a-4ad2-85bf-c0eac2537c9d", "name": "load_p1rlv10540_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4829cd2f-7e61-4386-89ce-89d77d5ef5cf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "029b3287-e402-41d2-ba35-dc675176b103"}}}}, {"uuid": "779f5336-f165-4153-927c-a3b56b0c95df", "name": "4c549c39-eef7-4182-949e-97c202c2c5cf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3798783675992279, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6151141774255103, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "36fa9d3b-a675-47fe-8787-cbff3d8847d9", "name": "936c33b0-831b-434b-b429-dc6b6e5a83fe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "779f5336-f165-4153-927c-a3b56b0c95df"}}}]}, {"uuid": "2be448aa-639b-445d-93b9-eff7ac15c311", "name": "load_p1rlv10540_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4829cd2f-7e61-4386-89ce-89d77d5ef5cf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "36fa9d3b-a675-47fe-8787-cbff3d8847d9"}}}}, {"uuid": "872c6067-a8d5-4cf8-9df4-5bffa0ff49f2", "name": "75df7eb9-d32f-44f3-bffe-0c74d23011a3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9115470716545817, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7511996531223851, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b4e1f0ad-c09e-4b3d-91a8-e3e50dcc5fa4", "name": "e09b0864-5e4c-4a3f-bdf7-c34e3e6c2884", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "872c6067-a8d5-4cf8-9df4-5bffa0ff49f2"}}}]}, {"uuid": "447fbe14-d0f5-428a-ae6e-897576c45644", "name": "load_p1rlv10544_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c722b89-fdaf-416f-863e-02b443375ba1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b4e1f0ad-c09e-4b3d-91a8-e3e50dcc5fa4"}}}}, {"uuid": "d8732fcd-8c59-44e7-a017-e1215105f5fa", "name": "72fe6248-d802-4be6-8a03-77d6d027095e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9115470716545817, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7511996531223851, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "443403d0-6584-4bf0-a96a-f0f8755d8610", "name": "8b01779b-6a18-45ef-9644-0f429d6aa12b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d8732fcd-8c59-44e7-a017-e1215105f5fa"}}}]}, {"uuid": "4c73c470-77cf-4169-81a9-d2e62d49ce9a", "name": "load_p1rlv10544_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c722b89-fdaf-416f-863e-02b443375ba1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "443403d0-6584-4bf0-a96a-f0f8755d8610"}}}}, {"uuid": "34640cc1-c224-4d24-b99f-215e00359092", "name": "fc449386-6b31-4ddc-b229-a11c4e93b3fc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6295328634326751, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9988748196040309, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e761bf5d-8dac-40fe-bcc1-784c02d7c9e0", "name": "0d32055b-85ed-43e6-84b0-ea0daf522bd5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "34640cc1-c224-4d24-b99f-215e00359092"}}}]}, {"uuid": "43ed04f3-eff1-4a13-8cf6-62a67d684189", "name": "load_p1rlv10563_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8a10822-398f-441e-a5ca-73303d832183"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e761bf5d-8dac-40fe-bcc1-784c02d7c9e0"}}}}, {"uuid": "2bb093c4-e0e8-4fbe-b20d-2c543a778bb4", "name": "882a7e93-5e51-4249-ad96-1a17e1d7aef4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6295328634326751, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9988748196040309, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ec28bff4-9338-43fc-be62-87fa847f6b55", "name": "1c446171-7668-4308-bfea-5de0daefc0d8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2bb093c4-e0e8-4fbe-b20d-2c543a778bb4"}}}]}, {"uuid": "1f8e033b-4c97-4409-a9ed-ef376cf47405", "name": "load_p1rlv10563_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8a10822-398f-441e-a5ca-73303d832183"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ec28bff4-9338-43fc-be62-87fa847f6b55"}}}}, {"uuid": "1f09440e-cd9a-4892-8523-67a089753aaa", "name": "f3ba15c3-6897-4cf9-b966-1be649810e54_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.140962173014189, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10805830108563602, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d6e738d1-f311-47c7-8ff0-3779b081757e", "name": "0f67960a-e395-41cb-a379-2cf8e66d43c4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1f09440e-cd9a-4892-8523-67a089753aaa"}}}]}, {"uuid": "63d2901e-e1f7-46b7-9244-31a4776e7c0a", "name": "load_p1rlv10573_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94677ede-fd5c-4fbb-bfcd-98cf67b56913"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d6e738d1-f311-47c7-8ff0-3779b081757e"}}}}, {"uuid": "4f079056-6c3e-4ff4-a67f-efe20d6a13e6", "name": "7b2273a6-6447-4fb9-916b-ff2a0a658219_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.140962173014189, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10805830108563602, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0aca7f90-a560-460a-9f18-8ba07af4701d", "name": "3aec8eb6-8ec5-4038-9e34-f5081eae467d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4f079056-6c3e-4ff4-a67f-efe20d6a13e6"}}}]}, {"uuid": "072eddd9-9ee0-4cee-894b-68a9ea4c645b", "name": "load_p1rlv10573_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94677ede-fd5c-4fbb-bfcd-98cf67b56913"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0aca7f90-a560-460a-9f18-8ba07af4701d"}}}}, {"uuid": "73e7c137-a605-4cb7-bbf3-26cdeed2315f", "name": "87f74108-c47a-4732-8a5e-ba596786e074_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6027984746974515, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12293402966163972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ba9cf4ad-f3fd-4227-a19b-2aaad62123f8", "name": "22278bf8-f8dd-4f1c-ab87-9b73b7dbe1d7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "73e7c137-a605-4cb7-bbf3-26cdeed2315f"}}}]}, {"uuid": "4f33ad95-2a70-4770-a098-910ca9f52b56", "name": "load_p1rlv10574_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b4caeee-6304-4a25-a7d8-44c6014b5e37"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ba9cf4ad-f3fd-4227-a19b-2aaad62123f8"}}}}, {"uuid": "875f2236-e580-4421-bef0-f41c0eed5036", "name": "d4a9c871-3f9d-48a9-a724-ec5889420a13_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6027984746974515, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12293402966163972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "98ae50de-25e8-45e5-9aaf-3f1a06befbc1", "name": "dd6ab7a6-3919-4a87-995c-03d757d7f8e2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "875f2236-e580-4421-bef0-f41c0eed5036"}}}]}, {"uuid": "f9a00871-20ba-4f21-bebb-33613bf841e2", "name": "load_p1rlv10574_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b4caeee-6304-4a25-a7d8-44c6014b5e37"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "98ae50de-25e8-45e5-9aaf-3f1a06befbc1"}}}}, {"uuid": "091bf3dc-4ce0-4c92-b4f3-148a0f482cdf", "name": "dc3fc21e-dadf-45ba-8bec-19f14fc3a3c7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.535252812300099, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.708042162201308, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "424df63a-d4c4-49df-9896-f4bf2b07c473", "name": "228ebb4b-92bf-41c6-9d2b-4a7c1797794f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "091bf3dc-4ce0-4c92-b4f3-148a0f482cdf"}}}]}, {"uuid": "cfbdf53b-5867-474e-b60c-f40634e804eb", "name": "load_p1rlv10576_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25141e20-0a65-4905-b37f-954ed1a8751c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "424df63a-d4c4-49df-9896-f4bf2b07c473"}}}}, {"uuid": "7019b336-5d5d-484f-b921-9e5aca1d3c6d", "name": "59fe0be2-26b2-41b7-bdc7-7ba3350faf0f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.535252812300099, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.708042162201308, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8cee5bc4-c540-4440-ad24-55b653fd412a", "name": "b4b37538-0702-4489-94ad-1451bdbccbff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7019b336-5d5d-484f-b921-9e5aca1d3c6d"}}}]}, {"uuid": "f9ccbd09-813c-4072-bc2f-1aa56b889574", "name": "load_p1rlv10576_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25141e20-0a65-4905-b37f-954ed1a8751c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8cee5bc4-c540-4440-ad24-55b653fd412a"}}}}, {"uuid": "ce073e85-7f43-43d1-88c2-155ddf7a246d", "name": "00f06c4c-ddc4-4abf-afb5-bdceb596c710_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.261177426225613, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7908181369947367, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a8f9af20-7f19-4bf7-be41-a37c69963df6", "name": "702b8ae1-6285-494d-b679-55db28da0e5f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ce073e85-7f43-43d1-88c2-155ddf7a246d"}}}]}, {"uuid": "32de3124-470c-493e-8a0b-1157ef1af7ae", "name": "load_p1rlv10582_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdfa726f-5606-4ae2-b358-ad664dd7b0e3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a8f9af20-7f19-4bf7-be41-a37c69963df6"}}}}, {"uuid": "f9edb153-baa9-45c1-a696-5e44278f86b3", "name": "ad721249-ca51-45d8-962e-0a9e773e5d9d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.261177426225613, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7908181369947367, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "baaa64b4-3737-4051-9f0b-9d3727462fde", "name": "44ff648c-5a1e-45c3-89bb-8ace748e5de5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f9edb153-baa9-45c1-a696-5e44278f86b3"}}}]}, {"uuid": "442c6a76-1f2b-444a-9201-70b55cf27e61", "name": "load_p1rlv10582_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdfa726f-5606-4ae2-b358-ad664dd7b0e3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "baaa64b4-3737-4051-9f0b-9d3727462fde"}}}}, {"uuid": "33441858-6598-49d0-8453-71c6d90501c5", "name": "1e4ff4e9-c297-4aa5-84e2-f849bcffb5d2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "506125d1-1fed-441c-a96c-ff7cc5ab005f", "name": "8a782648-1632-4447-8a78-89d4d790e3c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "33441858-6598-49d0-8453-71c6d90501c5"}}}]}, {"uuid": "b419a8f6-93e5-4c8f-96c2-6e7960421ba5", "name": "load_p1rlv10583_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0431d17-75da-48c1-965c-875f61b0e9bf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "506125d1-1fed-441c-a96c-ff7cc5ab005f"}}}}, {"uuid": "46ae0867-dcb5-467b-8c07-d3a5302c3791", "name": "010b32c2-c545-4787-be8e-2f7c02fb95ad_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b8dd710d-416d-4930-9f88-b0fefa62cea2", "name": "e09b0ffd-aa74-4154-815a-e46564fce253", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "46ae0867-dcb5-467b-8c07-d3a5302c3791"}}}]}, {"uuid": "9e6b3a5b-3f3a-4880-ba5f-dae0d358a4e7", "name": "load_p1rlv10583_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0431d17-75da-48c1-965c-875f61b0e9bf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b8dd710d-416d-4930-9f88-b0fefa62cea2"}}}}, {"uuid": "a71bb0d6-7cd5-4cb0-aa39-4b03fcbf501f", "name": "6e85531c-5724-434e-bf41-258885a0b74e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.283752349161772, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1583018658461228, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a14c57e3-8928-429f-b8b6-434759fd2792", "name": "05c4c798-47ad-4584-b26d-777b063fcd5b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a71bb0d6-7cd5-4cb0-aa39-4b03fcbf501f"}}}]}, {"uuid": "affed099-9528-466f-9ba6-f50f7bd56991", "name": "load_p1rlv10586_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfbe5665-c020-455a-addc-d3f9514735ed"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a14c57e3-8928-429f-b8b6-434759fd2792"}}}}, {"uuid": "706a7727-9c14-44bb-9f42-f5769b154fbf", "name": "0f2287e2-6648-4316-a7e5-c85a81a46ccb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.283752349161772, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1583018658461228, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "65400728-b7be-4d80-bb6e-68e381270709", "name": "50ffc628-e234-4147-8964-d3c900648e60", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "706a7727-9c14-44bb-9f42-f5769b154fbf"}}}]}, {"uuid": "aca6ee26-2121-4078-a1fb-7eefb2af7234", "name": "load_p1rlv10586_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfbe5665-c020-455a-addc-d3f9514735ed"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "65400728-b7be-4d80-bb6e-68e381270709"}}}}, {"uuid": "998df9b0-50aa-4706-962c-b6a9c63af559", "name": "d8a9d3c7-8558-4027-ab66-7f6ca44c0b08_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.580529910152944, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3492768846801997, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f740fd31-5393-4c25-9cbd-5143edc3f377", "name": "865924bd-36b9-4409-8ca2-1d232656ec43", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "998df9b0-50aa-4706-962c-b6a9c63af559"}}}]}, {"uuid": "98a2757d-3c5d-47f5-a5ef-a267cb357eac", "name": "load_p1rlv10589_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53019a8a-b453-4add-9d2d-e4ab380fce67"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f740fd31-5393-4c25-9cbd-5143edc3f377"}}}}, {"uuid": "c736f350-7e92-4bcd-a808-503bf3dded9c", "name": "8e8b7b9b-4a12-48fd-a14c-20c44555255a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.580529910152944, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3492768846801997, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "179147ef-6495-4bc7-9ace-5174b9ffd0fb", "name": "c488a22b-700a-4256-a5a1-a4d9e1d21a6e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c736f350-7e92-4bcd-a808-503bf3dded9c"}}}]}, {"uuid": "b467a724-c9b6-4c0a-90eb-b75a3fd0f403", "name": "load_p1rlv10589_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53019a8a-b453-4add-9d2d-e4ab380fce67"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "179147ef-6495-4bc7-9ace-5174b9ffd0fb"}}}}, {"uuid": "e0c1e9bf-a608-43ec-b3ab-ff05515704f1", "name": "30465b35-19b7-4740-949a-2d5f1389c11f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.781684048838155, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7643971440160673, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0924a091-904d-42f7-b649-d8c4e062b684", "name": "ec220ee0-75c1-431e-9f5d-98b007931647", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e0c1e9bf-a608-43ec-b3ab-ff05515704f1"}}}]}, {"uuid": "43b43c8c-05dc-4444-9fed-3c3eea1e50be", "name": "load_p1rlv10596_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aad9ea92-9403-4ac0-9aaf-7e845b8c7bb5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0924a091-904d-42f7-b649-d8c4e062b684"}}}}, {"uuid": "212866d9-892a-44ab-9d78-1fa02458a3cc", "name": "f82a8ffb-3899-42d7-8198-177451892f51_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.781684048838155, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7643971440160673, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "516ee468-42ac-4367-941a-45593dd976de", "name": "b737aa9d-6fdd-472a-913f-78c8fe79ed87", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "212866d9-892a-44ab-9d78-1fa02458a3cc"}}}]}, {"uuid": "7b7838ce-89c4-413f-9761-111972a4b000", "name": "load_p1rlv10596_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aad9ea92-9403-4ac0-9aaf-7e845b8c7bb5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "516ee468-42ac-4367-941a-45593dd976de"}}}}, {"uuid": "4d25b7f3-e1e0-432c-bbd2-20c4982bffda", "name": "b7d458c4-81f5-4535-9a34-c06bdafbc719_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.133667846972055, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2625504562375869, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "291e100a-66a8-41c0-bb8e-9d18f760f9dc", "name": "2aa56bbc-393b-4963-891e-67d320f18d6c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4d25b7f3-e1e0-432c-bbd2-20c4982bffda"}}}]}, {"uuid": "7fd0a1eb-8e77-42a0-8a43-1990b29e2e1a", "name": "load_p1rlv10600_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "feb19590-c5f4-4982-9e99-20599f08cfe7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "291e100a-66a8-41c0-bb8e-9d18f760f9dc"}}}}, {"uuid": "93c34184-8439-410b-ab1a-54995d21afe4", "name": "1d458fa6-b09d-4bc8-ade0-0eaf6f62856b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.133667846972055, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2625504562375869, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8afd019e-2169-40ea-b70e-02b9578356bb", "name": "207faf6b-8f69-40e4-97fe-33d345d76c58", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "93c34184-8439-410b-ab1a-54995d21afe4"}}}]}, {"uuid": "e6bf0bb1-8209-47b9-9304-84e1a3ec0e95", "name": "load_p1rlv10600_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "feb19590-c5f4-4982-9e99-20599f08cfe7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8afd019e-2169-40ea-b70e-02b9578356bb"}}}}, {"uuid": "b5dece36-50a7-4842-bbf9-9cdcf07baef7", "name": "8767fde3-ad7a-414e-bc9e-ca67510d2a2c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.35395787140957025, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.14845654114897794, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "71bb45c2-d377-4a99-a4d5-f04aab1c26a7", "name": "1a4c4159-647d-4a55-940a-3d3bc5b56df3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5dece36-50a7-4842-bbf9-9cdcf07baef7"}}}]}, {"uuid": "962db928-09f8-4d43-9e77-fd32dd920c61", "name": "load_p1rlv10610_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b91354e-ce50-44d0-a959-fa451bb9cf20"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "71bb45c2-d377-4a99-a4d5-f04aab1c26a7"}}}}, {"uuid": "3b307419-3523-499b-8ab5-3e84ec6d323b", "name": "bb104de1-36db-46bf-81e0-7ebfe6c1d871_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.35395787140957025, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.14845654114897794, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c328b7ae-4b82-457d-8a1a-9810e282362a", "name": "376a780a-f7e2-4b6a-9e1c-adbbc7cad426", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3b307419-3523-499b-8ab5-3e84ec6d323b"}}}]}, {"uuid": "295f6e77-8da3-43b6-8193-d01761e2adff", "name": "load_p1rlv10610_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b91354e-ce50-44d0-a959-fa451bb9cf20"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c328b7ae-4b82-457d-8a1a-9810e282362a"}}}}, {"uuid": "5a920664-46e5-44a4-abf9-38560768e114", "name": "fc0d786d-53e1-449d-9803-734d144740c8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9149869461814677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5767582022429075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "47fe32f7-b3b9-4ee4-902c-48cc953c93f6", "name": "e6cb8855-dec5-415f-911d-297d7831ccb9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5a920664-46e5-44a4-abf9-38560768e114"}}}]}, {"uuid": "3da235eb-7577-4aab-8863-c8474cb6de00", "name": "load_p1rlv10615_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b175fcb-d1ee-44eb-8f89-826e40c5db1d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "47fe32f7-b3b9-4ee4-902c-48cc953c93f6"}}}}, {"uuid": "4d15b95c-82d8-4b91-aeb5-50fbe216e6de", "name": "f61c42da-6a48-4219-ab9b-8fc1f38764dd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9149869461814677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5767582022429075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8c4eedf7-f50b-42fd-8871-6790d0feb8a4", "name": "c9fda510-ad07-4e41-a244-893e99990fa6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4d15b95c-82d8-4b91-aeb5-50fbe216e6de"}}}]}, {"uuid": "6601651a-f399-4530-9b0b-c9fd05796b8e", "name": "load_p1rlv10615_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b175fcb-d1ee-44eb-8f89-826e40c5db1d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8c4eedf7-f50b-42fd-8871-6790d0feb8a4"}}}}, {"uuid": "2b7045b6-1362-42cf-bb6c-31cf6d4cae79", "name": "ed9bb46e-4447-4388-b0d3-1b09ad2dc42d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7464189326227366, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4011494318939581, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bec56e7a-528d-4b92-b5d0-486b1cbee7fc", "name": "a26888a3-858e-406b-ac7a-2ab68649b0c6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2b7045b6-1362-42cf-bb6c-31cf6d4cae79"}}}]}, {"uuid": "236e5d7e-1f9a-461d-844a-39414ced353d", "name": "load_p1rlv10616_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a5717e0-080e-46ae-918a-64fe4fcba5d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bec56e7a-528d-4b92-b5d0-486b1cbee7fc"}}}}, {"uuid": "4e4ad82d-6794-4073-ac45-9bf871ccf4c6", "name": "ce82cb31-9d2e-498a-a992-9599980183e2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7464189326227366, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4011494318939581, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a2a28822-0c17-4424-bb12-be4aa4b6af2a", "name": "24e55c3b-f642-4d33-84ba-33e0d4172e30", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4e4ad82d-6794-4073-ac45-9bf871ccf4c6"}}}]}, {"uuid": "43c97500-210e-4c50-abff-6d9608e600f9", "name": "load_p1rlv10616_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a5717e0-080e-46ae-918a-64fe4fcba5d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a2a28822-0c17-4424-bb12-be4aa4b6af2a"}}}}, {"uuid": "463f6149-b5d4-438f-a16d-4586f0bc0a43", "name": "422be16a-bf20-40ce-ad49-3394e9c866a2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.316539553342243, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9980015331306656, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d6cd3808-bd69-4b1c-a105-5654fa60cf31", "name": "91573b38-6c73-490f-82a5-e86402cf9f87", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "463f6149-b5d4-438f-a16d-4586f0bc0a43"}}}]}, {"uuid": "29eea145-22f9-4150-94ad-3764b540ef65", "name": "load_p1rlv10621_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "374d5417-b2c4-4d16-9b91-d2f519921fd8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d6cd3808-bd69-4b1c-a105-5654fa60cf31"}}}}, {"uuid": "1644862a-e0b2-4ebb-830d-5aa02ef2083c", "name": "029f2c31-f226-4c23-bfc7-08d84532d0e7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.316539553342243, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9980015331306656, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0d6655f1-c352-4e7b-980a-9045ce071e1e", "name": "a1e08948-18d1-4591-9457-112ac5261a7e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1644862a-e0b2-4ebb-830d-5aa02ef2083c"}}}]}, {"uuid": "2ed5b3ea-f3ae-475e-8aa6-c5bfe5aa1b73", "name": "load_p1rlv10621_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "374d5417-b2c4-4d16-9b91-d2f519921fd8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0d6655f1-c352-4e7b-980a-9045ce071e1e"}}}}, {"uuid": "c31478e6-d929-4e98-b045-c71b4087ad9e", "name": "c06ea238-dd56-4f76-a18a-9b96099385f1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.45600682921886, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9975893759791478, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7b0fcda8-4fd9-4888-a3c8-7a064f3a0514", "name": "20858e21-f5be-4bc2-a069-a8068e7695f4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c31478e6-d929-4e98-b045-c71b4087ad9e"}}}]}, {"uuid": "9ee800d6-2926-45c5-b6d4-172a40ee6b6e", "name": "load_p1rlv10627_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32406d7d-51f9-4c16-900b-526985e5f62b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7b0fcda8-4fd9-4888-a3c8-7a064f3a0514"}}}}, {"uuid": "8d18bbd5-8fcc-4978-8b60-29e2529c0513", "name": "6ae0e2e9-df9d-4148-97f8-233de83aa4f4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.45600682921886, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9975893759791478, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4b6b3d03-cac6-4782-b4c3-d9055a264d8b", "name": "db365dd3-dfa0-4c92-9bfc-e5963b6beced", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8d18bbd5-8fcc-4978-8b60-29e2529c0513"}}}]}, {"uuid": "a2c989ea-ede9-4302-b016-020257901a81", "name": "load_p1rlv10627_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32406d7d-51f9-4c16-900b-526985e5f62b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4b6b3d03-cac6-4782-b4c3-d9055a264d8b"}}}}, {"uuid": "653ced00-1a70-4461-a7f6-a46782d611fb", "name": "b0d67803-8e00-442d-b29d-be88928222a0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.625789834877447, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.7705314525486966, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f000b9e4-f294-460c-9c34-682dee4dd32f", "name": "8089d052-21f9-42c0-a786-82669cbf06ec", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "653ced00-1a70-4461-a7f6-a46782d611fb"}}}]}, {"uuid": "7bbb89a7-837a-40c9-81e6-6140afcbb9bc", "name": "load_p1rlv10629_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e183b3e8-d995-4f1e-baee-8d9d4add157e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f000b9e4-f294-460c-9c34-682dee4dd32f"}}}}, {"uuid": "c75500b4-b35d-407d-8f47-15b6ddee22c7", "name": "6a8d26b5-3a9c-429a-9e31-330ff08e2951_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.625789834877447, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.7705314525486966, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e561abf6-354f-47f3-b5b8-2822f6d8891b", "name": "9627e5cb-4670-4bea-8f37-6b4ac968697f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c75500b4-b35d-407d-8f47-15b6ddee22c7"}}}]}, {"uuid": "d30485b2-f695-4972-b2a0-8205cb6a63c6", "name": "load_p1rlv10629_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e183b3e8-d995-4f1e-baee-8d9d4add157e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e561abf6-354f-47f3-b5b8-2822f6d8891b"}}}}, {"uuid": "0be7dab3-4ef7-4396-908e-c67399cca48a", "name": "bdcfe216-985a-423d-a716-8996ebdea531_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.125662061080136, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6733739749908499, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "28e783ef-c07f-4016-a491-53d49ddc21c8", "name": "26f86049-1b09-4339-ac49-8d0f10195020", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0be7dab3-4ef7-4396-908e-c67399cca48a"}}}]}, {"uuid": "09da0e23-f708-49f8-b813-bda8c90d15ae", "name": "load_p1rlv10630_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d60a935-dc9b-48ea-8ee7-9b682452035e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "28e783ef-c07f-4016-a491-53d49ddc21c8"}}}}, {"uuid": "c647e0fd-2e92-431a-8bb0-efebf3669424", "name": "b698fe6e-a967-423a-be37-144d8a5edea4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.125662061080136, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6733739749908499, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b71ca818-e973-4c59-9900-3bf0adb156fa", "name": "314aeea4-6250-4fa3-a96c-542ebc6e63f0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c647e0fd-2e92-431a-8bb0-efebf3669424"}}}]}, {"uuid": "5785d1c0-ba23-47eb-8707-a652c3394c89", "name": "load_p1rlv10630_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d60a935-dc9b-48ea-8ee7-9b682452035e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b71ca818-e973-4c59-9900-3bf0adb156fa"}}}}, {"uuid": "28b97377-d18d-4b60-9fca-e275e912c1c0", "name": "1eb51cbf-a614-4010-8d85-3031944396ef_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4699462180170992, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3815978523472859, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a04d5ba8-580f-4c23-afea-273c028b13a0", "name": "3ca967da-a3b3-44f3-a92f-2c7122f74989", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "28b97377-d18d-4b60-9fca-e275e912c1c0"}}}]}, {"uuid": "bb0803a9-ffed-4930-85ac-23fc778bea77", "name": "load_p1rlv10634_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3184f056-3b5f-403d-86a0-f9b28d6bb3e3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a04d5ba8-580f-4c23-afea-273c028b13a0"}}}}, {"uuid": "a7f4f6a8-df1c-44b1-9861-e21c9ec35731", "name": "9b69478f-847b-4ba5-9717-b8f663214aff_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4699462180170992, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3815978523472859, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "955bb2fc-75c9-456e-b65a-14916d6ced7b", "name": "2527f77e-53d9-412a-a32a-f3ea5d666ff1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a7f4f6a8-df1c-44b1-9861-e21c9ec35731"}}}]}, {"uuid": "b95dbc99-087a-46b2-bee8-c253dafd753a", "name": "load_p1rlv10634_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3184f056-3b5f-403d-86a0-f9b28d6bb3e3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "955bb2fc-75c9-456e-b65a-14916d6ced7b"}}}}, {"uuid": "a027f1ba-5e36-4e14-8867-e8750b9b3e88", "name": "77d960dd-6e4b-4835-af96-4ff160700260_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.444725768387703, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6902267912659802, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "751a9fe0-cc15-4d54-976f-9c9b44796aa8", "name": "f869e91b-9bbd-41eb-b0d9-b723b1f74a78", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a027f1ba-5e36-4e14-8867-e8750b9b3e88"}}}]}, {"uuid": "074c693a-da67-459d-b817-3848a9649671", "name": "load_p1rlv10637_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9510bd0-2bba-4522-bfbe-20b94ea400b6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "751a9fe0-cc15-4d54-976f-9c9b44796aa8"}}}}, {"uuid": "70233a64-93d7-48a5-a06f-0600b5583265", "name": "97d43e0e-f26c-4fdc-ba4f-dbe0fac30736_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.444725768387703, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6902267912659802, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e046118c-7973-4191-a90f-8d40c5b13230", "name": "da65b232-5e9a-486f-a95b-08db42c934d3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "70233a64-93d7-48a5-a06f-0600b5583265"}}}]}, {"uuid": "78a39f4f-3259-49ea-a016-d0b6b770a82a", "name": "load_p1rlv10637_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9510bd0-2bba-4522-bfbe-20b94ea400b6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e046118c-7973-4191-a90f-8d40c5b13230"}}}}, {"uuid": "fadd79c0-580a-4d5e-9b5e-4da9d0191025", "name": "421e5657-d3b4-4c77-910e-a3470738ed61_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.639205904339139, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.495473092652384, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "296cc9cb-beef-41c6-ae8e-7d039b1b7402", "name": "ca951ebf-49ea-4e9c-926c-27e69045a428", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fadd79c0-580a-4d5e-9b5e-4da9d0191025"}}}]}, {"uuid": "83f977da-d0de-4535-baeb-367c8d9a3bed", "name": "load_p1rlv10641_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73ada6ad-ace7-46c1-80f7-2cb33cf4cdb3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "296cc9cb-beef-41c6-ae8e-7d039b1b7402"}}}}, {"uuid": "6244ef9d-3ee0-4a79-a3cf-e130b5de1618", "name": "082e46e7-c3cd-4225-8e60-096b9eb9a590_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.639205904339139, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.495473092652384, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "521f0d48-d008-471b-b45d-f7bf007a4ceb", "name": "ca87f831-2281-423e-803b-1aac098aaabb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6244ef9d-3ee0-4a79-a3cf-e130b5de1618"}}}]}, {"uuid": "6bb625d2-9233-43f7-8321-cfc6b33e6e72", "name": "load_p1rlv10641_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73ada6ad-ace7-46c1-80f7-2cb33cf4cdb3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "521f0d48-d008-471b-b45d-f7bf007a4ceb"}}}}, {"uuid": "f91053fa-fba9-4b1a-94f3-b5dfda7e789f", "name": "55e3c28f-a550-42dc-b7cc-cb2f5f0dddfd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5996895391512607, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5332968923160806, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "da312d03-f181-4ea8-8476-b4e00dc50cb3", "name": "67cf474e-c021-428e-a983-8816bde7e8f8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f91053fa-fba9-4b1a-94f3-b5dfda7e789f"}}}]}, {"uuid": "e3969318-5b8f-4511-815b-c97286011e74", "name": "load_p1rlv10663_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8198c1c5-67e0-49b9-b11a-1f266f7f4bcb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "da312d03-f181-4ea8-8476-b4e00dc50cb3"}}}}, {"uuid": "6957f6ed-5631-42d6-9d60-cee07aa633d1", "name": "a2574217-f0bc-401c-aa12-2fe1c5ab5bb8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5996895391512607, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5332968923160806, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "85f0f261-6c1b-4794-ac26-c0f8f6be3265", "name": "da6eba67-b155-4618-ae2b-bf28e68e16c8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6957f6ed-5631-42d6-9d60-cee07aa633d1"}}}]}, {"uuid": "90ca281a-a8a7-4109-9b92-b7053ff76551", "name": "load_p1rlv10663_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8198c1c5-67e0-49b9-b11a-1f266f7f4bcb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "85f0f261-6c1b-4794-ac26-c0f8f6be3265"}}}}, {"uuid": "364ef7a1-6b22-425f-aa38-1667cc9652de", "name": "b02ac72c-6bab-4491-a7df-9856c068a576_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9149869461814677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5767582022429075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "12c2a122-0ec2-4129-90ee-9a330e839fb7", "name": "a142bbc2-148a-4fa0-be13-8a785682e3e2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "364ef7a1-6b22-425f-aa38-1667cc9652de"}}}]}, {"uuid": "e5b3e471-5f92-44ad-b659-16e3ab78dcf4", "name": "load_p1rlv10720_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3d48c0e-704d-4205-94a2-ee74be7ae350"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "12c2a122-0ec2-4129-90ee-9a330e839fb7"}}}}, {"uuid": "2ebeaab4-4842-4216-bd44-71dc5c2a7f6f", "name": "c7a07059-5ecf-411b-bee2-5ceb38f53633_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9149869461814677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5767582022429075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "41144dbe-6edf-48e6-931c-82121205ff38", "name": "212c5a0a-514f-4b2c-8912-4cef4b7adb80", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2ebeaab4-4842-4216-bd44-71dc5c2a7f6f"}}}]}, {"uuid": "d4f4e6d2-0731-455b-a58f-11e4d5d1b78e", "name": "load_p1rlv10720_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3d48c0e-704d-4205-94a2-ee74be7ae350"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "41144dbe-6edf-48e6-931c-82121205ff38"}}}}, {"uuid": "7049ada4-9114-4342-95bf-162266ecb2ba", "name": "209d18ad-3da4-4a0a-a18d-139fd7eff92e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.459276697523187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8425022918187992, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b16a6e95-c8f5-4782-94af-ed256de9d106", "name": "bb9c6d31-7bb7-4c8a-b7fc-eb53006db484", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7049ada4-9114-4342-95bf-162266ecb2ba"}}}]}, {"uuid": "a45093a1-aeb2-4aad-9a1c-57eef425994a", "name": "load_p1rlv10955_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75dbf8f0-4cb6-49b7-a2a5-f98e9ff4b8df"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b16a6e95-c8f5-4782-94af-ed256de9d106"}}}}, {"uuid": "da9d1374-3cb5-497a-97ba-27c9750ad746", "name": "0730f85a-c922-453d-bd82-9ee41aa7376d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.459276697523187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8425022918187992, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "08eb6627-ce4a-4673-957c-3df6796e63f0", "name": "b114394d-af7c-435f-ad7a-d1779837681a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "da9d1374-3cb5-497a-97ba-27c9750ad746"}}}]}, {"uuid": "d03d68b7-65eb-4249-be52-dd2a1dbe7650", "name": "load_p1rlv10955_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75dbf8f0-4cb6-49b7-a2a5-f98e9ff4b8df"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "08eb6627-ce4a-4673-957c-3df6796e63f0"}}}}, {"uuid": "f40aa2e5-798f-468f-93f9-958f2ae92bfd", "name": "811e6f6f-9ece-4150-80f3-983552fe8aac_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.42648220197083947, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17627708866943506, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e8a38e5e-7db6-4ecb-b58c-9dcaac9f11eb", "name": "71370420-00b4-4479-aee6-1c11890b72a5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f40aa2e5-798f-468f-93f9-958f2ae92bfd"}}}]}, {"uuid": "e5e82ab0-0cc3-4445-a080-eff62f94cd34", "name": "load_p1rlv11048_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a8fc823-6fe8-4a3b-9437-68aa751f5e3b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e8a38e5e-7db6-4ecb-b58c-9dcaac9f11eb"}}}}, {"uuid": "1013b4ee-68cb-4342-936f-ce6ebcddd288", "name": "b1fd9cc5-31c7-4176-b403-2656e3c2ce7a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.42648220197083947, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17627708866943506, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b678eeac-b15d-4766-8549-1eb6d5dc61bf", "name": "474536a9-ccf9-4eb4-9c23-35857083a349", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1013b4ee-68cb-4342-936f-ce6ebcddd288"}}}]}, {"uuid": "65b91a42-c72a-48d4-a306-71c83189ddca", "name": "load_p1rlv11048_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a8fc823-6fe8-4a3b-9437-68aa751f5e3b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b678eeac-b15d-4766-8549-1eb6d5dc61bf"}}}}, {"uuid": "8bb152c5-aaf8-40a7-8604-4360a5122b95", "name": "e31634b5-7017-47ab-b867-88b81e3a7163_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0788570276665777, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5949433355568994, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cf79dcb8-43f9-49d0-ab1e-f6e5cd137ec8", "name": "ea8a6cc2-20d2-42ad-a5cb-78d22731cb1c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8bb152c5-aaf8-40a7-8604-4360a5122b95"}}}]}, {"uuid": "ee8dcbf3-9e3a-431f-9108-40418a72d162", "name": "load_p1rlv11380_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f949a06a-817e-4666-95bb-9536ce06a694"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cf79dcb8-43f9-49d0-ab1e-f6e5cd137ec8"}}}}, {"uuid": "9fb0c3ac-d337-4dde-bedc-2f4bbba5ddef", "name": "f5c2b463-2dea-4336-8db0-a1001296e30a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0788570276665777, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5949433355568994, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5508212d-10cb-4e84-a89a-a39c0ba9e6e7", "name": "5db1c0a2-9f61-413e-b9fc-253e73f7889b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9fb0c3ac-d337-4dde-bedc-2f4bbba5ddef"}}}]}, {"uuid": "2dcd8ef1-01fd-44a8-af9e-6a40ebde70ab", "name": "load_p1rlv11380_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f949a06a-817e-4666-95bb-9536ce06a694"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5508212d-10cb-4e84-a89a-a39c0ba9e6e7"}}}}, {"uuid": "f11640f5-490c-4a9d-adbe-3a2bddcc1d95", "name": "630809d5-43e2-4522-b987-732d50a76bca_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.122083974307247, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.832996158964583, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "278ca58d-0aec-48ce-8f6d-022a2552ce18", "name": "ae7fadf0-a2dc-452a-a866-31b4daec1911", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f11640f5-490c-4a9d-adbe-3a2bddcc1d95"}}}]}, {"uuid": "34642993-ddc9-4c08-bf35-b04592e73168", "name": "load_p1rlv11384_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0c23aea-471f-4d10-9500-1bc14a67d7e7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "278ca58d-0aec-48ce-8f6d-022a2552ce18"}}}}, {"uuid": "360fefe8-8b88-4807-aa47-17a5de0df06d", "name": "d0ae83c6-a7c4-4e1a-95e5-bebea8ece424_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.122083974307247, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.832996158964583, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3bb00d31-4128-4f55-bdd8-9a989ab63a16", "name": "cd66eb38-760d-4dac-9177-b9385426979f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "360fefe8-8b88-4807-aa47-17a5de0df06d"}}}]}, {"uuid": "1431994c-a7e8-4e06-8ba2-4384f422d5b7", "name": "load_p1rlv11384_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0c23aea-471f-4d10-9500-1bc14a67d7e7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3bb00d31-4128-4f55-bdd8-9a989ab63a16"}}}}, {"uuid": "526a60db-5260-4cfe-a3d6-ce7cbc422a6b", "name": "cbaffa95-fa01-45a7-99ef-34477a88115a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 10.509020108523046, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.6522347064707315, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "79136e75-b2b8-4bd4-9360-0d672af1e684", "name": "55cb41d2-e75a-414e-8893-9f575d733c50", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "526a60db-5260-4cfe-a3d6-ce7cbc422a6b"}}}]}, {"uuid": "0cf0d892-3e55-4a93-a396-6b5d00cba278", "name": "load_p1rlv11385_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2115e8bb-fe49-49ad-8687-68feca212557"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "79136e75-b2b8-4bd4-9360-0d672af1e684"}}}}, {"uuid": "b2722973-8fe5-41d6-856b-01957ca2efb6", "name": "4c8dfd26-9575-44c2-8877-ec3dceddecec_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 10.509020108523046, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.6522347064707315, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c3a4d236-5526-4eaf-b69c-81f9f7b57cb6", "name": "eb107080-b20d-42c3-9e00-87dc33942c0e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b2722973-8fe5-41d6-856b-01957ca2efb6"}}}]}, {"uuid": "899f5896-8be0-4757-b0be-e3235ceff34b", "name": "load_p1rlv11385_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2115e8bb-fe49-49ad-8687-68feca212557"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c3a4d236-5526-4eaf-b69c-81f9f7b57cb6"}}}}, {"uuid": "98be4d9c-2302-41b6-9f5b-4124b7bedc5b", "name": "be52d5eb-3fdd-4f36-bc38-914bdf52b39f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.480517361983766, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0183082338731784, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e52315c8-e7e3-4682-8066-90ef82614883", "name": "0259a1c5-11af-4e90-a192-7575b8ccd45d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "98be4d9c-2302-41b6-9f5b-4124b7bedc5b"}}}]}, {"uuid": "4c2cd8dc-dc30-464f-a4f6-ae32fbbd247e", "name": "load_p1rlv11386_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f512d86-c9d9-4f58-9d5a-418d0732dc94"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e52315c8-e7e3-4682-8066-90ef82614883"}}}}, {"uuid": "9efa0853-fb2f-400c-ad76-17bc96185208", "name": "2d808018-f753-4122-8b76-c102272718fc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.480517361983766, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0183082338731784, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "78a80a75-a6a5-4450-b3a2-26efb704dc06", "name": "6a48081b-2edc-4ef6-96ff-51221e6a3bb5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9efa0853-fb2f-400c-ad76-17bc96185208"}}}]}, {"uuid": "f3b9c812-99d0-42c0-aaba-a48a0440d18c", "name": "load_p1rlv11386_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f512d86-c9d9-4f58-9d5a-418d0732dc94"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "78a80a75-a6a5-4450-b3a2-26efb704dc06"}}}}, {"uuid": "449a0c3d-1ba5-4099-9a54-1e94666184c9", "name": "16305d34-b9f3-4562-b126-f1a81d200b85_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4651344294517608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7736313908316925, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e7421110-4b71-4cca-9a89-108b52acf66b", "name": "16ac7d63-c464-4a44-91d6-7f7731be9d2b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "449a0c3d-1ba5-4099-9a54-1e94666184c9"}}}]}, {"uuid": "18607566-7803-4c38-875a-dcd43eb95cda", "name": "load_p1rlv11387_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbca8c57-0da4-4368-9821-7a9ca4282173"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e7421110-4b71-4cca-9a89-108b52acf66b"}}}}, {"uuid": "28751ce9-4f0f-43d8-a5a6-82b259be16d2", "name": "048de35a-8050-4d9a-99e1-996a10b8d873_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4651344294517608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7736313908316925, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "46cf857e-b861-4c96-9ddd-8f93f3999ff3", "name": "62942fa3-ff93-4763-b6e4-7e47e0ee32a5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "28751ce9-4f0f-43d8-a5a6-82b259be16d2"}}}]}, {"uuid": "242d0f50-b01f-465a-b6ad-42e3957d6adc", "name": "load_p1rlv11387_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbca8c57-0da4-4368-9821-7a9ca4282173"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "46cf857e-b861-4c96-9ddd-8f93f3999ff3"}}}}, {"uuid": "65dcd61c-606d-40c5-ac84-5c883bfd958a", "name": "7e0228c2-e3a9-4eb2-9609-4c43c4c479a4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4359784649582454, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.14838741475370543, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b35b4c6e-6f59-4eff-bcaa-d55880e1a26c", "name": "448c1537-1044-4341-8cc4-17303fdc01f6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "65dcd61c-606d-40c5-ac84-5c883bfd958a"}}}]}, {"uuid": "061ac5e1-4491-4054-a774-49521eab7009", "name": "load_p1rlv11388_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12377bf0-f258-4c29-ab26-e938c95ee25c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b35b4c6e-6f59-4eff-bcaa-d55880e1a26c"}}}}, {"uuid": "4c928ce3-4607-4184-a739-4aec1d7d889a", "name": "2631c714-8f91-4974-becb-b4af853a819c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4359784649582454, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.14838741475370543, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bcbddbf6-2fa2-44d7-8332-a0de0780b2c5", "name": "8b212604-4f4d-4843-a575-054512258d30", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4c928ce3-4607-4184-a739-4aec1d7d889a"}}}]}, {"uuid": "8a4b10c5-a6db-4ed7-8e35-6f998a22b4ae", "name": "load_p1rlv11388_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12377bf0-f258-4c29-ab26-e938c95ee25c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bcbddbf6-2fa2-44d7-8332-a0de0780b2c5"}}}}, {"uuid": "79d552d3-cee0-4a5c-b1a2-75be1d6a51c7", "name": "3bdb2f3f-9a78-4cc3-a63c-8cf570881f21_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5261964028176471, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5335215898246958, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7a49efe3-5daa-47c4-815e-2716df97977c", "name": "5fdfa4f1-eddf-4d3d-b9d7-0e9b2936dc09", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "79d552d3-cee0-4a5c-b1a2-75be1d6a51c7"}}}]}, {"uuid": "4ddb8c43-6e0c-4309-8132-cca83f8e4659", "name": "load_p1rlv11390_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b6420b1-3456-42fc-9266-c2b84e063cec"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7a49efe3-5daa-47c4-815e-2716df97977c"}}}}, {"uuid": "44b3e1b7-6f21-40fb-90f8-ada5d654828f", "name": "b0bbc030-b3ae-48cb-add4-c76f9579a136_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5261964028176471, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5335215898246958, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a1a95b33-a327-433e-a614-fe431f7fa246", "name": "592346aa-cb58-403e-b561-9fd691bdeddb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "44b3e1b7-6f21-40fb-90f8-ada5d654828f"}}}]}, {"uuid": "8b62b715-2222-4d0f-bb32-eb15d0362481", "name": "load_p1rlv11390_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b6420b1-3456-42fc-9266-c2b84e063cec"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a1a95b33-a327-433e-a614-fe431f7fa246"}}}}, {"uuid": "559142c0-923c-48cb-a663-08acf9b99abe", "name": "edd46b4f-039e-4197-bea5-a0a193e9034c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.056520022279634, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8635401886215074, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "755f07e7-916c-4a53-8b8e-fdbe8a86ed7e", "name": "8800987f-4611-48c6-be6e-61646d7a93f9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "559142c0-923c-48cb-a663-08acf9b99abe"}}}]}, {"uuid": "2f3b07f5-6d3b-47c6-b03f-62a581a26356", "name": "load_p1rlv11392_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e740a352-ac8f-4ae2-ace3-254fccd7f96f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "755f07e7-916c-4a53-8b8e-fdbe8a86ed7e"}}}}, {"uuid": "4574b2d1-fc8e-49ff-a25a-fc07d36b301d", "name": "e63794ba-c4ae-44ae-b439-bd3343a501d5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.056520022279634, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8635401886215074, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "756fa955-9680-480f-85b2-d5b52b29f99e", "name": "083c63fe-380e-41f3-9ba3-62772e37b557", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4574b2d1-fc8e-49ff-a25a-fc07d36b301d"}}}]}, {"uuid": "59c6d232-98a9-47e1-bed2-5e872041a8d2", "name": "load_p1rlv11392_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e740a352-ac8f-4ae2-ace3-254fccd7f96f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "756fa955-9680-480f-85b2-d5b52b29f99e"}}}}, {"uuid": "462390c9-21da-4beb-9fc6-0f0467cb6409", "name": "d7557778-2990-4193-bcab-760f907a022b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6676306342135938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5123446143614628, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a15ae177-76ec-43f0-a0c2-a1026e8ec787", "name": "dae2d185-f280-4645-9d77-2ef82f12b93c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "462390c9-21da-4beb-9fc6-0f0467cb6409"}}}]}, {"uuid": "278597eb-7589-4179-9c56-8147c045a63a", "name": "load_p1rlv11394_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "996d3e44-142c-42fa-bf4f-2bd1777122dd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a15ae177-76ec-43f0-a0c2-a1026e8ec787"}}}}, {"uuid": "3b3c4397-6414-48a5-990a-6ad45810e2a0", "name": "78e01f6b-d1e6-4496-bbec-41c47850519e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6676306342135938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5123446143614628, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ddd93c03-41d9-4a3c-81c1-1ba375c6c355", "name": "e342d2f3-4b04-4da0-9630-4b32275eb7c6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3b3c4397-6414-48a5-990a-6ad45810e2a0"}}}]}, {"uuid": "ab65142c-9c13-4a8c-8cc7-b104c63b5259", "name": "load_p1rlv11394_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "996d3e44-142c-42fa-bf4f-2bd1777122dd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ddd93c03-41d9-4a3c-81c1-1ba375c6c355"}}}}, {"uuid": "06de4b0e-2909-42a2-959d-aa5a6a240436", "name": "db623204-32c1-44e5-adc3-3c160b103c96_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0716401691896973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6949594139700135, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cb377bff-e6f7-4447-8797-48e32b35cd1a", "name": "0379a339-a2ec-462f-bf7e-b2e2e2a3cc96", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "06de4b0e-2909-42a2-959d-aa5a6a240436"}}}]}, {"uuid": "1e04e619-d127-4ea3-87ed-5eb9556ac87d", "name": "load_p1rlv11395_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29922f55-f36a-4b9e-8836-5f9dadd641b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cb377bff-e6f7-4447-8797-48e32b35cd1a"}}}}, {"uuid": "58db2d51-9c85-4843-83a6-cf19e369b34f", "name": "1c0b8270-742b-4189-8212-bf9144bc65af_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0716401691896973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6949594139700135, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "35c29600-c66e-4dc1-92ab-5574ce2dfe4e", "name": "cad04e0d-401c-4383-901c-67f3f7902974", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58db2d51-9c85-4843-83a6-cf19e369b34f"}}}]}, {"uuid": "908db140-2d30-4690-96be-fe82a41c7d68", "name": "load_p1rlv11395_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29922f55-f36a-4b9e-8836-5f9dadd641b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "35c29600-c66e-4dc1-92ab-5574ce2dfe4e"}}}}, {"uuid": "d5614689-653e-472f-9267-639e0d79a5f1", "name": "fa235b5c-542f-425f-8e7d-585216fa16af_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.8145950466373417, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09093602970127403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "736b85df-cb4e-4e9b-83cf-08ae8f791c33", "name": "9d31ebe3-0876-4f4a-962e-66d5f02222c8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d5614689-653e-472f-9267-639e0d79a5f1"}}}]}, {"uuid": "eb1321da-6da4-4467-b70d-211ce256bd9d", "name": "load_p1rlv11397_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fd316b0-fd98-4193-9c1b-aaa7d92a4284"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "736b85df-cb4e-4e9b-83cf-08ae8f791c33"}}}}, {"uuid": "c9ca1464-7f8d-4a34-9c17-7bcd4af77466", "name": "32f1b799-0314-4cee-9183-a6e1d85e616a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.8145950466373417, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09093602970127403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7ec03626-15d0-482f-8e2c-732f4fa3238e", "name": "de74e497-95d5-40ed-bb4b-e8d05267a90c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9ca1464-7f8d-4a34-9c17-7bcd4af77466"}}}]}, {"uuid": "716a39f1-ba9a-4a83-b6b0-1e8b432d48ac", "name": "load_p1rlv11397_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fd316b0-fd98-4193-9c1b-aaa7d92a4284"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7ec03626-15d0-482f-8e2c-732f4fa3238e"}}}}, {"uuid": "c88b7522-4bd8-49d0-bc8e-b13cc33d39ac", "name": "ac5c5c8d-2059-4ae0-a96e-2e4ef1fc7da5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 23.859207702115498, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3391872562704328, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d557504b-7f7f-4144-bab4-599b9a9b4147", "name": "b361a8d0-1846-477b-ad03-cdb801178674", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c88b7522-4bd8-49d0-bc8e-b13cc33d39ac"}}}]}, {"uuid": "1227d484-abf8-457b-9a16-2712f4293348", "name": "load_p1rlv11398_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97aa01fe-2e60-4617-8c89-d36f425087fe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d557504b-7f7f-4144-bab4-599b9a9b4147"}}}}, {"uuid": "5095d65a-f8f9-43ad-9509-bd1a682fb4de", "name": "1fdd615c-4a8b-45df-a664-b7afad3317cc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 23.859207702115498, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3391872562704328, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1100417b-7762-42c1-84e3-9df8982977b1", "name": "67c88a92-b4bf-420a-842a-9d6c7bf6ff8b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5095d65a-f8f9-43ad-9509-bd1a682fb4de"}}}]}, {"uuid": "ab6196e1-93f6-4f4a-ba8f-dfceaed4b375", "name": "load_p1rlv11398_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97aa01fe-2e60-4617-8c89-d36f425087fe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1100417b-7762-42c1-84e3-9df8982977b1"}}}}, {"uuid": "c85d0dcd-b204-4eab-b636-4bd71b02ac73", "name": "a34faa76-5042-44d6-a7c0-7fa364a76449_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.936474762797392, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1018059929469786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "93ed52e0-29fd-47f1-bcff-9e635f2710c4", "name": "fe1551b2-4899-4058-ba17-33095af84ca7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c85d0dcd-b204-4eab-b636-4bd71b02ac73"}}}]}, {"uuid": "0dd259e1-6337-42d8-8b1a-f1167ba06871", "name": "load_p1rlv11399_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68a9eead-8197-4e82-a444-2a4544ec9ddb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "93ed52e0-29fd-47f1-bcff-9e635f2710c4"}}}}, {"uuid": "475d83d0-97e4-4073-9eb4-c4054a6a73c6", "name": "58181977-2e65-49af-bac7-75f122b75525_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.936474762797392, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1018059929469786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "412f3c1c-8bd1-4f9a-8b78-ff10d0dc33af", "name": "442532b1-69f9-4bd4-be04-fd2195a09331", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "475d83d0-97e4-4073-9eb4-c4054a6a73c6"}}}]}, {"uuid": "14f5c982-a941-47eb-bbe3-5a71b7002ef0", "name": "load_p1rlv11399_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68a9eead-8197-4e82-a444-2a4544ec9ddb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "412f3c1c-8bd1-4f9a-8b78-ff10d0dc33af"}}}}, {"uuid": "1c93c64e-c366-4e8e-be51-80ed7c2dc1ab", "name": "a8d1b8f8-964b-4152-88cf-546f652122a5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7362273540893955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24527287728713068, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1f94519d-76c3-44f3-a4aa-a413daa3fc09", "name": "e9273d34-b533-405f-ab46-06cf3d1cbebd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1c93c64e-c366-4e8e-be51-80ed7c2dc1ab"}}}]}, {"uuid": "1a8b6d99-326a-4863-aafb-24b633c2de28", "name": "load_p1rlv11401_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a215d7dd-8081-4355-9c38-4fd3d2c859c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1f94519d-76c3-44f3-a4aa-a413daa3fc09"}}}}, {"uuid": "ed3a85b5-cc99-4309-803f-597146e69b7e", "name": "c2716fdb-6260-4b4e-99ee-3110b4c6e13b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7362273540893955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24527287728713068, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e6c2ba32-641e-40be-9196-97d7f0cdc413", "name": "e8b64d33-8988-4766-ac6b-b5cf996fed76", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ed3a85b5-cc99-4309-803f-597146e69b7e"}}}]}, {"uuid": "d2095444-e584-4f9e-96d6-7ee82d3f56cf", "name": "load_p1rlv11401_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a215d7dd-8081-4355-9c38-4fd3d2c859c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e6c2ba32-641e-40be-9196-97d7f0cdc413"}}}}, {"uuid": "19e6f0e2-d912-4218-9fd1-fd4d0924d194", "name": "217e84b9-c92a-4813-bda6-016f6ec450d4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.993849790823018, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8230403105677124, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "81000f39-1c4b-48e4-b9af-0b7e8a375a30", "name": "3e931a47-39f4-49a1-b7c1-d1a5dca4f47a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "19e6f0e2-d912-4218-9fd1-fd4d0924d194"}}}]}, {"uuid": "880c8a8f-8311-4eea-85c3-081629e5d51a", "name": "load_p1rlv11671_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "834a5733-5264-4adf-861a-25e494df3e37"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "81000f39-1c4b-48e4-b9af-0b7e8a375a30"}}}}, {"uuid": "fa41be16-4f77-4d8b-8d3c-5bded2c2b3d2", "name": "3a0c9a3d-d0d9-4cef-b356-9296bc4e6ebb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.993849790823018, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8230403105677124, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5de76861-367c-419e-9ebf-d23598dc70c8", "name": "c79e609b-1aa4-4707-894b-5b353a30e4b3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fa41be16-4f77-4d8b-8d3c-5bded2c2b3d2"}}}]}, {"uuid": "ffffb06b-53dd-40e2-88d0-c56f9b9119a7", "name": "load_p1rlv11671_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "834a5733-5264-4adf-861a-25e494df3e37"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5de76861-367c-419e-9ebf-d23598dc70c8"}}}}, {"uuid": "7b0aea3d-5a84-4c93-8187-72c99666a6e7", "name": "9ef80507-36c4-4ed5-a827-d4bab96aa770_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.207629741893862, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.47552489685620736, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cdaab1e9-9218-4f89-879c-17def2df400d", "name": "b090e00b-d7e5-485d-998b-bb3e5a4156b2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b0aea3d-5a84-4c93-8187-72c99666a6e7"}}}]}, {"uuid": "4280bfa9-be32-40fd-bdb0-2e913cfe06f7", "name": "load_p1rlv11674_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "45f2a901-e4f7-4055-a3e2-b60c61d5033e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cdaab1e9-9218-4f89-879c-17def2df400d"}}}}, {"uuid": "942399c1-c215-463d-ab01-2b5b49c33988", "name": "2ada6355-9751-4aa1-8e94-23629ffcbcea_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.207629741893862, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.47552489685620736, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "88679627-5a13-4b2f-9104-c1ab907ef8d2", "name": "7dc64782-55da-4ebf-9774-248dfaf2aeb3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "942399c1-c215-463d-ab01-2b5b49c33988"}}}]}, {"uuid": "3afad982-a47a-4bfd-b962-d5030608149a", "name": "load_p1rlv11674_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "45f2a901-e4f7-4055-a3e2-b60c61d5033e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "88679627-5a13-4b2f-9104-c1ab907ef8d2"}}}}, {"uuid": "7fdeae6b-bad2-4d38-a3eb-b1b886bb88b2", "name": "58c28d80-812f-4f45-b252-f3b925518e56_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.350180554065672, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.234423023465851, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "78047efa-5aae-4c22-bbfd-1e309fce9b3d", "name": "5014b4f3-eb2f-4d8a-b195-fedddd1a282a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7fdeae6b-bad2-4d38-a3eb-b1b886bb88b2"}}}]}, {"uuid": "e21bce72-76a7-41e5-bfdb-2fd16a75d549", "name": "load_p1rlv11677_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b2f121a-2202-43c0-8684-81913a5d6ea9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "78047efa-5aae-4c22-bbfd-1e309fce9b3d"}}}}, {"uuid": "3fb2b49c-5421-416a-81b8-ed45941c710b", "name": "010a5d40-5063-4cec-b10e-a8c6e97802f0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.350180554065672, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.234423023465851, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cbba316b-4388-493d-bebf-b65b224f77b1", "name": "9dc512e3-833a-4d0a-901e-d9d6f764a902", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3fb2b49c-5421-416a-81b8-ed45941c710b"}}}]}, {"uuid": "82bec9a8-854a-4931-b6be-6add2702d1a6", "name": "load_p1rlv11677_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b2f121a-2202-43c0-8684-81913a5d6ea9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cbba316b-4388-493d-bebf-b65b224f77b1"}}}}, {"uuid": "73a7b9d9-ecd8-46e9-8986-42f2efd7f8c6", "name": "84a7323c-c0fb-4d34-8f47-c23cb918fafe_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.646242553828346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.7481060562472628, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2a45bee3-8c33-4cbe-a582-6377ecc23b9f", "name": "84a7323c-c0fb-4d34-8f47-c23cb918fafe_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.646242553828346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.7481060562472628, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7b0b3590-6acf-417b-9bb2-452f23225443", "name": "84a7323c-c0fb-4d34-8f47-c23cb918fafe_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.646242553828346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.7481060562472628, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f34e4e1c-6c8f-4059-adc9-2b64ec93e326", "name": "f086a3d6-c467-4700-abc5-5d2277d44341", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "73a7b9d9-ecd8-46e9-8986-42f2efd7f8c6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2a45bee3-8c33-4cbe-a582-6377ecc23b9f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b0b3590-6acf-417b-9bb2-452f23225443"}}}]}, {"uuid": "199bfa85-465c-4650-8ef3-90f96b88b204", "name": "load_p1rlv11679", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4747e0f3-2a66-4e5a-8160-ac0aabe34489"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f34e4e1c-6c8f-4059-adc9-2b64ec93e326"}}}}, {"uuid": "0e0463d4-ce3e-4fc6-9932-5ad1716ba8a4", "name": "065c9709-49a5-4a99-969e-d1ab3384fb45_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5348201699646123, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21241824123648728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f04a5ba1-dccd-43ea-9d4c-422a4ef9bc8f", "name": "a950f1cc-c8ce-471b-b119-37def2974705", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0e0463d4-ce3e-4fc6-9932-5ad1716ba8a4"}}}]}, {"uuid": "eeae5cd3-47cb-420f-82eb-e82981fc3166", "name": "load_p1rlv11684_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02aef971-5f4a-4ca8-aa33-cce34517bd44"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f04a5ba1-dccd-43ea-9d4c-422a4ef9bc8f"}}}}, {"uuid": "c113a2d0-7a1a-4ef0-b68c-e48e85a1090f", "name": "54701ebb-2c42-4b9d-9413-2113bdd4b2d5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5348201699646123, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21241824123648728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "146aded8-811d-43e7-93c3-2ff6315ddb15", "name": "4fdd7731-7414-4d6a-b123-66bb72d3735f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c113a2d0-7a1a-4ef0-b68c-e48e85a1090f"}}}]}, {"uuid": "39427790-3cc9-4d35-b072-1b8584b28d52", "name": "load_p1rlv11684_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02aef971-5f4a-4ca8-aa33-cce34517bd44"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "146aded8-811d-43e7-93c3-2ff6315ddb15"}}}}, {"uuid": "0f0f3eff-f75b-412b-b376-fd15c18d9230", "name": "711648f9-ebb7-4f4e-b932-f24da15200e6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7134847388598258, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.27646838411203456, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2074fde9-c64d-43a4-9028-6b9f09dd0c72", "name": "910b07e4-fe64-4347-a582-ae11ab6afa54", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0f0f3eff-f75b-412b-b376-fd15c18d9230"}}}]}, {"uuid": "f74274b2-e40e-49ec-a06e-9124509405b4", "name": "load_p1rlv11686_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cda8e361-98b6-49bd-a3ff-30a036a3dc6f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2074fde9-c64d-43a4-9028-6b9f09dd0c72"}}}}, {"uuid": "5b421636-ffa4-4703-9f40-c5fa17a9ef1a", "name": "0009cc4f-de5f-4ad5-aa48-0ff3c85e7cb0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7134847388598258, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.27646838411203456, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a935d79-007f-4e78-9f82-58519fc58985", "name": "64531b1b-d21e-47e0-90b2-87975e64e9bc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b421636-ffa4-4703-9f40-c5fa17a9ef1a"}}}]}, {"uuid": "0128e4c0-7225-4072-81cb-76e07c494424", "name": "load_p1rlv11686_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cda8e361-98b6-49bd-a3ff-30a036a3dc6f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a935d79-007f-4e78-9f82-58519fc58985"}}}}, {"uuid": "bcaa9aa5-7611-4cab-8e97-f648f007f6ec", "name": "8ac0ffc9-1f1f-4e44-b05b-3c6c4e9f4bcf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.685213211371405, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7584354740780123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b6106aee-0e71-4823-9b54-b821dbe6e9e3", "name": "2518ab62-028f-406d-8805-cd8ff9e7c663", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bcaa9aa5-7611-4cab-8e97-f648f007f6ec"}}}]}, {"uuid": "2f03a659-6950-4b38-824c-fcab53770ada", "name": "load_p1rlv11779_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0ba1408-17da-4678-8b04-90c616c3fb48"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b6106aee-0e71-4823-9b54-b821dbe6e9e3"}}}}, {"uuid": "54d15814-1f86-46d8-ba4e-8005594b9e8c", "name": "673f5872-4f13-461c-8547-73d1563f4ca2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.685213211371405, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7584354740780123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "68e84740-bc6d-46b3-b5a1-de230ba2ba8c", "name": "d8fcf121-24ec-4589-af9b-16f85e167894", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "54d15814-1f86-46d8-ba4e-8005594b9e8c"}}}]}, {"uuid": "36b3f0e7-e125-444a-953f-0f418ce90d34", "name": "load_p1rlv11779_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0ba1408-17da-4678-8b04-90c616c3fb48"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "68e84740-bc6d-46b3-b5a1-de230ba2ba8c"}}}}, {"uuid": "2bc5ddc5-f9cf-4c31-a698-e45162a59f52", "name": "de86f7c4-960b-434d-a501-6e2a48c45b5e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8140781365796688, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5845737413475921, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f8b6903-d695-4864-8bd1-5d6ef43823d3", "name": "9f5d99d3-8bbb-4f4b-82b3-c6fa3a499604", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2bc5ddc5-f9cf-4c31-a698-e45162a59f52"}}}]}, {"uuid": "ae28e7f9-10c4-4478-beb9-3cda7def6e12", "name": "load_p1rlv11780_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e9a574d-9537-417a-a811-e22d84b8ea53"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f8b6903-d695-4864-8bd1-5d6ef43823d3"}}}}, {"uuid": "0bb832a9-296f-4ab9-b79f-c6729e9a95f1", "name": "b62bc94e-46b0-4893-b9d9-63b0d76a65c4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8140781365796688, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5845737413475921, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d6007af3-04d8-4d6b-98a0-75e82c07ad9e", "name": "aa693dc2-7f08-4d51-bd8d-957884a3cb4b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0bb832a9-296f-4ab9-b79f-c6729e9a95f1"}}}]}, {"uuid": "2b081bb3-2ae6-44e9-bff1-82782c105da7", "name": "load_p1rlv11780_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e9a574d-9537-417a-a811-e22d84b8ea53"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d6007af3-04d8-4d6b-98a0-75e82c07ad9e"}}}}, {"uuid": "384cf2bf-2e3f-496f-8c9f-7c60d688c039", "name": "8a16d511-aa5c-4d7e-8a2a-dc06a8786cf8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.511185229285174, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8722130080127372, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6a3dec04-d7d9-4d23-9487-257b4c3812db", "name": "49c94614-c682-4183-a3ee-47532aeabbd9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "384cf2bf-2e3f-496f-8c9f-7c60d688c039"}}}]}, {"uuid": "d9cfe7dd-04e6-4dcf-ab7f-2acbe28a3430", "name": "load_p1rlv11781_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28fd9f7c-0195-4529-a972-aa60eced47d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6a3dec04-d7d9-4d23-9487-257b4c3812db"}}}}, {"uuid": "d02a4dfd-0db0-4c84-a0d0-55acac4da244", "name": "f894fb6a-1944-4860-81b8-0d511b69b152_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.511185229285174, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8722130080127372, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "04f35fd9-0ef5-4f14-a6e3-cefc0476f467", "name": "65a6d6bc-d2e4-4d3c-87c0-3c49631c0586", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d02a4dfd-0db0-4c84-a0d0-55acac4da244"}}}]}, {"uuid": "784301f3-c814-4f30-a094-a5ad526eafc4", "name": "load_p1rlv11781_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28fd9f7c-0195-4529-a972-aa60eced47d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "04f35fd9-0ef5-4f14-a6e3-cefc0476f467"}}}}, {"uuid": "c29d78d2-6f86-4a75-8639-46b5737b9f3a", "name": "da9297a7-e14d-4032-80c3-bd916fb0f82e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9571742049653674, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.37384849940856246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c91df66f-cf2c-4308-9e5e-6ae3c4236103", "name": "598bffc5-e44d-4424-b327-473c6b33c699", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c29d78d2-6f86-4a75-8639-46b5737b9f3a"}}}]}, {"uuid": "d4d57c2d-e4fb-45e4-8ca1-5861e1d03e26", "name": "load_p1rlv11782_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "496fc854-bbf8-463b-b16c-12dd1b444cc6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c91df66f-cf2c-4308-9e5e-6ae3c4236103"}}}}, {"uuid": "59ec2523-a40e-4626-83a9-942fb8b00d3c", "name": "0175315c-636a-4bdf-8ec1-9ece9762cfd7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9571742049653674, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.37384849940856246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "55fe2d83-23b8-4e04-bb5f-c0c39fa59d22", "name": "7ffab4d1-ae5f-47c4-bc80-1b5ef215933d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "59ec2523-a40e-4626-83a9-942fb8b00d3c"}}}]}, {"uuid": "dc1725f4-043c-489e-ad6e-a489b6a3ddde", "name": "load_p1rlv11782_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "496fc854-bbf8-463b-b16c-12dd1b444cc6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "55fe2d83-23b8-4e04-bb5f-c0c39fa59d22"}}}}, {"uuid": "719f3565-2a90-447f-b37f-62c4575685a5", "name": "74b0364c-70f7-4cfa-9a50-696d19276a50_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6943701970081404, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21264462112520055, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "04a97427-3eb0-4dd5-8318-2b1618f2db99", "name": "25c4c1f0-dda3-4377-ab72-f6328c96ad2c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "719f3565-2a90-447f-b37f-62c4575685a5"}}}]}, {"uuid": "c0d0846d-b13d-4842-be91-f5890fae2efa", "name": "load_p1rlv11783_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3890375-c01d-44d2-93f9-8d9d60da8852"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "04a97427-3eb0-4dd5-8318-2b1618f2db99"}}}}, {"uuid": "a833347b-51ca-4335-a3b7-2815a8802252", "name": "715e0283-8919-4ab8-8785-bd42398faa71_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6943701970081404, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21264462112520055, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d4366736-a6a8-4466-bdda-dd0d4f71e800", "name": "c972beca-c3aa-48b8-9bb8-2e95b0231cd1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a833347b-51ca-4335-a3b7-2815a8802252"}}}]}, {"uuid": "7a0211f4-3574-4963-8c61-ef4aa454aab7", "name": "load_p1rlv11783_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3890375-c01d-44d2-93f9-8d9d60da8852"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d4366736-a6a8-4466-bdda-dd0d4f71e800"}}}}, {"uuid": "74aeab76-c309-4409-b010-a63870f4cc44", "name": "2bb9988e-44b9-4e7a-a6e6-1457f5fd33ec_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.991741378519742, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22993168819558238, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "70c39461-4170-4085-8dd6-3521bdb1cee8", "name": "f6e7cbfd-d137-4329-92ee-5b9518fb7227", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "74aeab76-c309-4409-b010-a63870f4cc44"}}}]}, {"uuid": "bbaa94b7-26a0-4490-b73f-3f48efcd8109", "name": "load_p1rlv11784_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b66df0bc-6159-42fa-bf49-b8ad17d0e6aa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "70c39461-4170-4085-8dd6-3521bdb1cee8"}}}}, {"uuid": "14682214-bd52-4703-aeee-3855f6362b25", "name": "b01eff19-3110-434c-8ce9-8d5f9e392f71_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.991741378519742, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22993168819558238, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4c696357-ac6d-45a4-962b-355e9c7383a4", "name": "419de2c8-9215-4618-8fc3-0beef31859c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "14682214-bd52-4703-aeee-3855f6362b25"}}}]}, {"uuid": "f229a1db-0bdf-43d2-865e-4cddd2b3dd8c", "name": "load_p1rlv11784_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b66df0bc-6159-42fa-bf49-b8ad17d0e6aa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4c696357-ac6d-45a4-962b-355e9c7383a4"}}}}, {"uuid": "81aa2444-620f-45cc-98de-960fa593c2a6", "name": "5f30cec8-7b02-4fd1-b591-a2178d76d175_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9304883858291884, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.26579705258029934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5b8b6400-52cf-4605-af6d-5c3539407e22", "name": "892222e6-9006-4e8c-b1aa-6f9b3a88f2ca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "81aa2444-620f-45cc-98de-960fa593c2a6"}}}]}, {"uuid": "67f8b117-f8aa-4709-9095-1e625b55aaea", "name": "load_p1rlv11785_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ed0eb774-fcc3-417f-a8a4-fbdb825cc106"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5b8b6400-52cf-4605-af6d-5c3539407e22"}}}}, {"uuid": "1a8a6352-2858-476d-b4ae-541f4571c5d7", "name": "7cc3f58f-d2dc-4bee-9e76-d93a317bd5c2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9304883858291884, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.26579705258029934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "96c26c44-bee9-4f3d-8e1d-05ca261685b3", "name": "3fa9c194-4aa5-456e-a3bb-6475f8f83efb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1a8a6352-2858-476d-b4ae-541f4571c5d7"}}}]}, {"uuid": "7097c4ee-e786-4b71-b2a3-dd97cf49206a", "name": "load_p1rlv11785_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ed0eb774-fcc3-417f-a8a4-fbdb825cc106"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "96c26c44-bee9-4f3d-8e1d-05ca261685b3"}}}}, {"uuid": "b645010e-a80c-4a8e-847c-83155db97703", "name": "48b0ad64-80f4-4225-8b12-69d1c1fce2b4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9049571169929809, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.186253723079565, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "634e1d2e-df5c-4213-ab8a-387c3beb319a", "name": "43db1fb5-a161-48cd-b379-8efe6752dab5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b645010e-a80c-4a8e-847c-83155db97703"}}}]}, {"uuid": "70aaccc7-152f-4181-a716-cb618ede64a9", "name": "load_p1rlv11786_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b15fc66-89d9-483b-9c9f-9b0f39a63b29"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "634e1d2e-df5c-4213-ab8a-387c3beb319a"}}}}, {"uuid": "a27cf930-a2b9-45cb-833a-29d62bb98417", "name": "843c52bb-2b47-41ee-b817-12e7df53e0e9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9049571169929809, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.186253723079565, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4d47c6dc-872d-406b-a442-3bc658bf26b7", "name": "d430dd13-01cb-4cda-9824-6fb09a44693f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a27cf930-a2b9-45cb-833a-29d62bb98417"}}}]}, {"uuid": "257419d1-b753-4d96-bdce-38e1a1cd8134", "name": "load_p1rlv11786_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b15fc66-89d9-483b-9c9f-9b0f39a63b29"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4d47c6dc-872d-406b-a442-3bc658bf26b7"}}}}, {"uuid": "b05a753d-3db7-48b3-b47a-249c98ff3be1", "name": "a4b00cd0-fd5a-4f22-9a52-ed3053b4ee85_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.074192704000552, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.129078804753558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c988968-65a0-4532-a19d-556a07293824", "name": "44cf0c3d-0316-4a19-8733-0a867704b781", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b05a753d-3db7-48b3-b47a-249c98ff3be1"}}}]}, {"uuid": "e253f6fb-990c-4d8b-8948-9a3229cac708", "name": "load_p1rlv12028_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1dfd848-b639-41b5-ad95-2c03a51bd36b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c988968-65a0-4532-a19d-556a07293824"}}}}, {"uuid": "203f3b4c-a1b7-4d7d-8dde-44bba643968d", "name": "a49857dd-c662-47fa-b3d3-1bc2676ae6c5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.074192704000552, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.129078804753558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "07a841f3-9e9e-435e-8921-90257903027f", "name": "5e806831-a196-41a9-9872-c316842d0c89", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "203f3b4c-a1b7-4d7d-8dde-44bba643968d"}}}]}, {"uuid": "f55cbd96-3d00-4c50-9b1e-7949b1ccf7fa", "name": "load_p1rlv12028_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1dfd848-b639-41b5-ad95-2c03a51bd36b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "07a841f3-9e9e-435e-8921-90257903027f"}}}}, {"uuid": "552e95b7-8899-4680-b787-bd09d88fcbad", "name": "d624f5a9-8df5-49d9-8aab-f0ab2829963b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9920550244580673, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.016709072862991, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4a17a3d5-f916-40a8-9a3c-a75fabf7c4b9", "name": "04652eab-da1b-44bb-b119-da71f87b7c49", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "552e95b7-8899-4680-b787-bd09d88fcbad"}}}]}, {"uuid": "15f6d0d3-47f6-405d-860f-4c1f270e1b38", "name": "load_p1rlv12157_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc4d79bb-8ba3-4146-9d50-16db48ffec22"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4a17a3d5-f916-40a8-9a3c-a75fabf7c4b9"}}}}, {"uuid": "616909e4-20b5-4c69-8ff7-6e76d1373619", "name": "9a778301-544c-4279-8090-78f38718cff6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9920550244580673, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.016709072862991, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a0eda67-fcf7-4f79-9913-20f1f19267d3", "name": "3797bb29-31a1-4c97-b879-c67117445909", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "616909e4-20b5-4c69-8ff7-6e76d1373619"}}}]}, {"uuid": "7cf4078b-8cea-45d9-b31f-65e4f30ac480", "name": "load_p1rlv12157_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc4d79bb-8ba3-4146-9d50-16db48ffec22"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0a0eda67-fcf7-4f79-9913-20f1f19267d3"}}}}, {"uuid": "93349afb-bb23-4e5a-96c4-865535c7fce2", "name": "387701da-b42d-4acc-9a36-d349f1506115_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4651344294517608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7736313908316925, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bbe48d7c-1401-44fa-9c7f-809f2a444159", "name": "a44c1150-9305-4d3e-b8c4-f08012ed1336", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "93349afb-bb23-4e5a-96c4-865535c7fce2"}}}]}, {"uuid": "90927d12-f7db-4258-9750-300ae537663f", "name": "load_p1rlv12214_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df9d9de2-6929-48a4-a390-c0e2f129b374"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bbe48d7c-1401-44fa-9c7f-809f2a444159"}}}}, {"uuid": "940f19a6-726f-4ae7-ab9c-62ed4a687ede", "name": "c22de480-94ab-4386-8777-6352bb23c4a9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4651344294517608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7736313908316925, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a359518f-9c6f-44f3-bba7-02c74e67773b", "name": "7cafa9c5-8e2b-4908-8492-7901adf43b91", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "940f19a6-726f-4ae7-ab9c-62ed4a687ede"}}}]}, {"uuid": "be825c77-6ca2-4d5d-99a4-53a5543c2ea2", "name": "load_p1rlv12214_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df9d9de2-6929-48a4-a390-c0e2f129b374"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a359518f-9c6f-44f3-bba7-02c74e67773b"}}}}, {"uuid": "8000ba09-9e9b-47e7-9248-e5cd7eb89b1f", "name": "9390d150-0a92-45a1-a68b-a305c8617dcd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.84153235443771, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.447226409705929, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7c1a452d-e2b6-417d-a4f3-f8b3e9b59441", "name": "413ffaf3-a662-40e4-a1cb-4187df3cca66", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8000ba09-9e9b-47e7-9248-e5cd7eb89b1f"}}}]}, {"uuid": "a5fee8da-8631-4a13-a56e-4b3ac2d97499", "name": "load_p1rlv12217_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4d26673-c304-41de-8b5b-149552601ba4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7c1a452d-e2b6-417d-a4f3-f8b3e9b59441"}}}}, {"uuid": "c90df63f-8a49-4713-98f6-06f17ab46792", "name": "ea12689a-7116-40d9-a027-ca1635ed75dc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.84153235443771, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.447226409705929, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0e05b6fc-4c45-4fd7-9c22-8340c45a3606", "name": "8b56535d-9f54-4ad3-9c6a-791882e318e3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c90df63f-8a49-4713-98f6-06f17ab46792"}}}]}, {"uuid": "e485265f-9f8d-4245-ad17-5d4e5e1c3807", "name": "load_p1rlv12217_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4d26673-c304-41de-8b5b-149552601ba4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0e05b6fc-4c45-4fd7-9c22-8340c45a3606"}}}}, {"uuid": "eb75ab7d-98c0-4140-aef1-328cd7e4116d", "name": "0760525e-b253-41d0-b2cd-687cd73d9c1e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.799969889792979, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7055837837850989, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "042dfb11-6154-4b13-9408-0cd2ab142536", "name": "ab587f0c-6725-497c-ad32-aa49117ef7a8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eb75ab7d-98c0-4140-aef1-328cd7e4116d"}}}]}, {"uuid": "bc041c92-4b53-4a56-a2fb-e457b789cd43", "name": "load_p1rlv12222_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cee79fe8-f140-4be9-aa6b-d56e37fb6857"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "042dfb11-6154-4b13-9408-0cd2ab142536"}}}}, {"uuid": "b0d438e5-c608-402c-b4f6-9f25bd01a42e", "name": "c6b2d280-584e-43d4-a753-6be9b18ab723_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.799969889792979, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7055837837850989, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e7a368d6-2f67-4798-acb9-d269a780643e", "name": "d8f0ae6e-e5fc-404e-94db-798335a77be1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b0d438e5-c608-402c-b4f6-9f25bd01a42e"}}}]}, {"uuid": "79f820d2-8c76-454c-8b6f-c034813dfa94", "name": "load_p1rlv12222_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cee79fe8-f140-4be9-aa6b-d56e37fb6857"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e7a368d6-2f67-4798-acb9-d269a780643e"}}}}, {"uuid": "8a292298-d87c-40ba-99b3-0870bd235430", "name": "4aff0686-b279-4769-8696-0f117f3f32ab_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0087998942532215, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8303357169547151, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7a23e6bd-80a6-48f6-9573-655b5666a234", "name": "4fab9f05-0766-47da-9a87-043511271416", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a292298-d87c-40ba-99b3-0870bd235430"}}}]}, {"uuid": "1711e0a2-ee71-472d-9af5-5fa31beeaac0", "name": "load_p1rlv12225_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8e1f797-9417-447c-8a08-cf00a462ef14"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7a23e6bd-80a6-48f6-9573-655b5666a234"}}}}, {"uuid": "4f1b5334-965c-4525-a322-5fe06c498bb7", "name": "ea7d87bf-96a1-4601-b23b-bda186f96246_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0087998942532215, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8303357169547151, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bdaf1aa2-43b3-47cd-9d94-8e7d2bb7b510", "name": "398b200b-5935-44e0-ab49-e5e703cf9715", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4f1b5334-965c-4525-a322-5fe06c498bb7"}}}]}, {"uuid": "4b1b40e1-5681-448e-a18b-39482f3ba885", "name": "load_p1rlv12225_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8e1f797-9417-447c-8a08-cf00a462ef14"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bdaf1aa2-43b3-47cd-9d94-8e7d2bb7b510"}}}}, {"uuid": "b8deb33a-f898-4d69-97ce-bf091c2f724e", "name": "384f4eb4-eab8-4690-886d-9cf71c4744d7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "55635006-f0f4-4f03-80e7-0beecf5255f6", "name": "6d2bbb29-4ca4-4dd4-8fef-eb4cb60eb63e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b8deb33a-f898-4d69-97ce-bf091c2f724e"}}}]}, {"uuid": "d0db2faa-7719-4473-9f95-ecdc785a82de", "name": "load_p1rlv12538_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b42c2471-9114-4042-980e-dd226ad024a3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "55635006-f0f4-4f03-80e7-0beecf5255f6"}}}}, {"uuid": "38ca2981-1679-4764-a838-f05b5da5b7b2", "name": "e4d803a9-4542-4d57-88bc-b050a947ef29_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b0938b16-1cb9-4e1a-8d43-6ef059d68218", "name": "5ecac895-5d8e-4356-a367-3fc11dfe5b1a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "38ca2981-1679-4764-a838-f05b5da5b7b2"}}}]}, {"uuid": "4bdaf9b4-ca85-4214-b3d0-fab6ecc04fa0", "name": "load_p1rlv12538_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b42c2471-9114-4042-980e-dd226ad024a3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b0938b16-1cb9-4e1a-8d43-6ef059d68218"}}}}, {"uuid": "7af170d2-f91e-49a1-b46a-9d1b3fdac5c2", "name": "fbc4c379-57b8-4715-be21-42a6b2e361f4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.019297318507635, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.02246974709606756, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1fac8763-3ee1-43e7-bcf3-41617c46e963", "name": "f8e332fc-ec82-416e-b3d6-8b14e1a23653", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7af170d2-f91e-49a1-b46a-9d1b3fdac5c2"}}}]}, {"uuid": "28b67365-ae57-4a50-9c3f-0d620c71a219", "name": "load_p1rlv12552_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c42d772-e2a8-45d4-9cf2-2edd7a567b35"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1fac8763-3ee1-43e7-bcf3-41617c46e963"}}}}, {"uuid": "a378f8a4-8021-485f-860d-aa2a2032d46d", "name": "c6a7766f-684b-4d18-8619-a3e8a6fb87ce_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.019297318507635, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.02246974709606756, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f2ffd1ed-8ac4-4d30-bf95-beddb8475dfb", "name": "87f2a343-b853-4cce-827f-1d2dbc76cb67", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a378f8a4-8021-485f-860d-aa2a2032d46d"}}}]}, {"uuid": "9667ccde-7679-492a-80de-2ab510342e72", "name": "load_p1rlv12552_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c42d772-e2a8-45d4-9cf2-2edd7a567b35"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f2ffd1ed-8ac4-4d30-bf95-beddb8475dfb"}}}}, {"uuid": "31838ae9-5bec-4bfe-83d3-5a758bb306f4", "name": "8d2dfc6e-c33b-4d6c-be06-4b5f020bb41a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2219087879829873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3595087789107823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "13e11be6-6fef-46bd-a8ff-df8d3810df63", "name": "7e84ed5f-2b1e-4383-92e9-5ec8f0524021", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "31838ae9-5bec-4bfe-83d3-5a758bb306f4"}}}]}, {"uuid": "5dda57ed-b319-494c-9d87-380540189d12", "name": "load_p1rlv12553_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a29aec49-62a4-41ec-a67c-a84470a23f7b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "13e11be6-6fef-46bd-a8ff-df8d3810df63"}}}}, {"uuid": "10f2e55a-4148-43f9-a8e9-4720e944f9db", "name": "f9bc0bd6-0fa0-4d6b-aa84-287b48754b10_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2219087879829873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3595087789107823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1efcf0f6-12e0-457b-994d-41864b64821c", "name": "f4aef277-ad74-480c-8e1d-45906fd74985", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "10f2e55a-4148-43f9-a8e9-4720e944f9db"}}}]}, {"uuid": "7ce39498-91c4-4f3a-bdee-ca51755f3d8f", "name": "load_p1rlv12553_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a29aec49-62a4-41ec-a67c-a84470a23f7b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1efcf0f6-12e0-457b-994d-41864b64821c"}}}}, {"uuid": "e17e5f3b-1fa7-4e02-83f1-70a065023638", "name": "0500e3cd-6e22-4a48-bd68-2da9bc824009_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "77c2f716-98c7-4441-bb4a-bb0c0f6784c8", "name": "0500e3cd-6e22-4a48-bd68-2da9bc824009_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bf053ec5-8ce2-4779-9c8a-07b6844e1fbc", "name": "0500e3cd-6e22-4a48-bd68-2da9bc824009_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c5a6b4d5-ace0-436b-827a-428dd72a82ca", "name": "a105b17e-37ea-4df0-8c38-0552a55db7ce", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e17e5f3b-1fa7-4e02-83f1-70a065023638"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "77c2f716-98c7-4441-bb4a-bb0c0f6784c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bf053ec5-8ce2-4779-9c8a-07b6844e1fbc"}}}]}, {"uuid": "c6d2bf5b-f470-40ce-b8e4-96cfd0e92a44", "name": "load_p1rlv12555", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc71e486-4a44-466d-bc57-85591b269949"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c5a6b4d5-ace0-436b-827a-428dd72a82ca"}}}}, {"uuid": "1cbd663f-6a1c-4ea8-bded-0d70d902cae6", "name": "f1be257d-cb3a-4fc0-8586-41749bc934a6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.885552109924766, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6041260127278384, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ffec3052-3abb-4450-8007-84eb1a135bdd", "name": "4dc44239-3a7f-4899-a30b-0117e115c1b5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1cbd663f-6a1c-4ea8-bded-0d70d902cae6"}}}]}, {"uuid": "7db8574c-df37-49fc-8c22-8dbf718a039b", "name": "load_p1rlv12557_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fe4d6ae-cca5-476c-981a-a1dcd27b1e84"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ffec3052-3abb-4450-8007-84eb1a135bdd"}}}}, {"uuid": "b0bf587d-8b6c-44a5-a550-676ae3aeb192", "name": "f4b5e26d-8b61-4ee2-8ecf-038f2fb4bca0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.885552109924766, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6041260127278384, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e6120965-3163-44d8-8795-e883b0e34afe", "name": "d3b636f0-790f-4e54-9421-c06065a70246", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b0bf587d-8b6c-44a5-a550-676ae3aeb192"}}}]}, {"uuid": "2ce60fb7-a0a5-4497-b6c9-5145427b22f3", "name": "load_p1rlv12557_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fe4d6ae-cca5-476c-981a-a1dcd27b1e84"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e6120965-3163-44d8-8795-e883b0e34afe"}}}}, {"uuid": "fceb259d-954e-4c0d-a150-78ac533baca1", "name": "e0c5a270-abfa-4883-8baf-ed86fb59ffb0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.408318732620361, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.41814988562464883, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "94430f1e-1b47-4835-9d87-a26d30ac25f4", "name": "5d608f62-d235-48f6-905d-fb4ad378a38e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fceb259d-954e-4c0d-a150-78ac533baca1"}}}]}, {"uuid": "b52d40e1-7dd4-4d66-932d-26e4adbf6420", "name": "load_p1rlv12558_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a427f20-861a-4616-9443-265beaeccca3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "94430f1e-1b47-4835-9d87-a26d30ac25f4"}}}}, {"uuid": "b67cc3a7-efc2-4b73-8760-243e73ec84e9", "name": "a519c9c5-243d-4164-8d71-d9ebf568709c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.408318732620361, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.41814988562464883, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7dad946a-64e6-471e-9d5a-f5c2b56b4453", "name": "28666f42-b2e8-4084-a71f-177b3f358f9a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b67cc3a7-efc2-4b73-8760-243e73ec84e9"}}}]}, {"uuid": "32210c0c-5a99-44d3-89da-dcd3a4957933", "name": "load_p1rlv12558_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a427f20-861a-4616-9443-265beaeccca3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7dad946a-64e6-471e-9d5a-f5c2b56b4453"}}}}, {"uuid": "a7aeb239-b12f-43d8-9254-ceaa8ce5e63e", "name": "7d4a04f8-e89e-4c6a-baff-658b68f7e66d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4ef0e256-0104-4670-ab8e-66c781b92406", "name": "dae4cac6-0ccf-403a-8a0b-4866a8108bc2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a7aeb239-b12f-43d8-9254-ceaa8ce5e63e"}}}]}, {"uuid": "01613cf8-4c62-4ab0-aaf7-05cb942bf041", "name": "load_p1rlv12559_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a47101-b6df-473e-9c7b-96e076c17931"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4ef0e256-0104-4670-ab8e-66c781b92406"}}}}, {"uuid": "512b1fd5-c86c-41ad-a872-0d065db783c7", "name": "65a5f5f0-0ae7-4772-9834-824f5cd68277_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ac9edb43-7944-49af-972a-36bc7f104596", "name": "450e2d61-d419-4788-9fe1-76e179c9155e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "512b1fd5-c86c-41ad-a872-0d065db783c7"}}}]}, {"uuid": "f31a4f65-f744-4d57-848a-782d2ce69a80", "name": "load_p1rlv12559_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a47101-b6df-473e-9c7b-96e076c17931"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ac9edb43-7944-49af-972a-36bc7f104596"}}}}, {"uuid": "8d05d7db-5906-45a2-b1df-57fb6360a6b9", "name": "f2f96b59-653b-4115-b388-497ff52e86b5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4cff9875-7386-458a-9b64-80156936c140", "name": "5af06e9b-23e0-4f6e-a121-7535fd7f88ca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8d05d7db-5906-45a2-b1df-57fb6360a6b9"}}}]}, {"uuid": "c907954e-7703-4c1f-9a10-7dfbbb090930", "name": "load_p1rlv12562_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b0417d3-820d-4daa-aec5-3dcf34e40e00"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4cff9875-7386-458a-9b64-80156936c140"}}}}, {"uuid": "31402909-c881-44f6-9600-4af29e18b80c", "name": "258b099f-96f3-42c9-97ce-6c940296fb86_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d734fea1-2101-4015-8765-d044ecca754e", "name": "718893c7-d6f5-46c0-89e9-ddff0d94b2ef", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "31402909-c881-44f6-9600-4af29e18b80c"}}}]}, {"uuid": "7d67f5e1-9d72-499d-a95a-be3277402376", "name": "load_p1rlv12562_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b0417d3-820d-4daa-aec5-3dcf34e40e00"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d734fea1-2101-4015-8765-d044ecca754e"}}}}, {"uuid": "57030d1d-0515-409b-aa4a-387c467d26ac", "name": "1a257e80-dfde-40c4-aa55-d37da79da837_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "350a7ad6-f872-4619-ae5f-cfd457befd45", "name": "1a257e80-dfde-40c4-aa55-d37da79da837_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "81199978-dcd1-47b2-8456-f39100ae2842", "name": "1a257e80-dfde-40c4-aa55-d37da79da837_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "320af1ec-76c0-4573-9c87-c3be63bcca88", "name": "6dade334-e8c5-4f6d-8279-8cd008e9a44d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "57030d1d-0515-409b-aa4a-387c467d26ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "350a7ad6-f872-4619-ae5f-cfd457befd45"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "81199978-dcd1-47b2-8456-f39100ae2842"}}}]}, {"uuid": "17b19812-d10c-4cc3-8e0b-b93942f5974c", "name": "load_p1rlv12567", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29476f95-f85b-4843-a847-3d9d99da3b74"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "320af1ec-76c0-4573-9c87-c3be63bcca88"}}}}, {"uuid": "f44bfd34-ad29-4174-a161-329b1224269d", "name": "36a08b46-936f-47a7-a34b-83acf6359197_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1813646779377422, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20173832232537287, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b8f01aa2-00fd-4dcd-95d3-ee92c7dc38da", "name": "ce99f5ba-9e66-476d-9b98-d5895b6afb7a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f44bfd34-ad29-4174-a161-329b1224269d"}}}]}, {"uuid": "8c1c77d8-e76c-4eda-bff9-22efc95cca94", "name": "load_p1rlv12936_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "019e419c-9f88-455a-bf48-b89531ed9e51"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b8f01aa2-00fd-4dcd-95d3-ee92c7dc38da"}}}}, {"uuid": "7f3d1ad9-9edb-4501-95e7-11dd23a50986", "name": "f8e1f177-5d01-4890-bfdc-99a3c60f7353_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1813646779377422, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20173832232537287, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "59dc5206-5cf4-4a62-8f4a-564ccced3760", "name": "7e6fccaf-608c-460d-b620-86aa98026b84", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7f3d1ad9-9edb-4501-95e7-11dd23a50986"}}}]}, {"uuid": "64ecfe23-c977-4298-9dc8-22e8d727ecc3", "name": "load_p1rlv12936_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "019e419c-9f88-455a-bf48-b89531ed9e51"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "59dc5206-5cf4-4a62-8f4a-564ccced3760"}}}}, {"uuid": "afa36572-c7ae-4d30-a2cf-34a94041a92f", "name": "95dd7527-7120-47c6-9afa-d40a630910f0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.674261199298095, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1525334183561808, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c66704e3-e385-47ce-b33a-e2c4375ef14e", "name": "7b00e015-39f0-4fc3-86ed-c4037ef252ea", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "afa36572-c7ae-4d30-a2cf-34a94041a92f"}}}]}, {"uuid": "a215654e-7a13-4de0-8afb-2f584ea13270", "name": "load_p1rlv12959_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8418804f-aad5-49df-9916-f427da5089c1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c66704e3-e385-47ce-b33a-e2c4375ef14e"}}}}, {"uuid": "ec3f59ba-2ece-4e43-8236-8c9de91b7627", "name": "5341f2d5-824e-4ce2-a368-edbf3ae10d37_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.674261199298095, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1525334183561808, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5dfda74d-6533-41b2-b54f-7101f1bd6c06", "name": "63791f0a-1239-4534-a7b3-c82111e806d7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ec3f59ba-2ece-4e43-8236-8c9de91b7627"}}}]}, {"uuid": "a9e2e550-8519-457a-9432-96ca8f3494ab", "name": "load_p1rlv12959_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8418804f-aad5-49df-9916-f427da5089c1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5dfda74d-6533-41b2-b54f-7101f1bd6c06"}}}}, {"uuid": "6bafed9c-a79a-43e6-a2a6-6262cbf57402", "name": "6465f966-6ad2-4637-b178-c99221f13579_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.622949952431687, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7401570066486144, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aa680a67-4712-49b6-a6ef-d2abb1acc56c", "name": "c0e0b38a-4d53-4faf-bc78-726feff62d84", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6bafed9c-a79a-43e6-a2a6-6262cbf57402"}}}]}, {"uuid": "a267a065-bc37-434d-b77a-bd9be5993b1e", "name": "load_p1rlv12971_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be845651-8e1c-4b6d-8633-fcbdfb1fd5d4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aa680a67-4712-49b6-a6ef-d2abb1acc56c"}}}}, {"uuid": "d9161e28-a0e8-4632-ae36-7b0369feafe5", "name": "ecbbdcd3-87d4-4093-8c08-7131f570fb59_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.622949952431687, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7401570066486144, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9836cc02-f8d9-4b59-aaeb-a80e647f8b53", "name": "5183ea73-8c25-4849-b8c8-ac8d8262be00", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d9161e28-a0e8-4632-ae36-7b0369feafe5"}}}]}, {"uuid": "aa3223c1-16c1-4b3f-99e7-4134ca4d6bf0", "name": "load_p1rlv12971_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be845651-8e1c-4b6d-8633-fcbdfb1fd5d4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9836cc02-f8d9-4b59-aaeb-a80e647f8b53"}}}}, {"uuid": "bf2243f3-2f82-411a-a167-14dd3432096e", "name": "0e011f34-06de-4749-9462-166fa6b5bab8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.629144238694082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9654448182756213, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0e6b89e2-09ac-43e4-9fdf-5d1f0467c088", "name": "6d835633-768b-4507-aef7-efebcacfcf21", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bf2243f3-2f82-411a-a167-14dd3432096e"}}}]}, {"uuid": "ef085e54-6201-46d3-8f05-3179724d75da", "name": "load_p1rlv13043_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3072c6c-3a40-4e49-bd00-febc8268b135"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0e6b89e2-09ac-43e4-9fdf-5d1f0467c088"}}}}, {"uuid": "048c2b39-a731-4873-a791-7b25cf4be610", "name": "da303c9d-b1f7-4042-8a61-3318d0388810_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.629144238694082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9654448182756213, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "68485ccc-34ca-4e0d-b041-cf3abda83f2c", "name": "9503fa22-df99-4b16-9624-ba5058855d48", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "048c2b39-a731-4873-a791-7b25cf4be610"}}}]}, {"uuid": "cf1311b1-6044-4a3b-b741-8eba3f6a730f", "name": "load_p1rlv13043_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3072c6c-3a40-4e49-bd00-febc8268b135"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "68485ccc-34ca-4e0d-b041-cf3abda83f2c"}}}}, {"uuid": "29ea63e7-0679-4c22-8880-178658313e08", "name": "b0f23629-383c-4a33-8600-91e1c7d72d0b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.67656735172194, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8569955192100605, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a9952cc1-e7a5-411b-bc2b-9b562df4ea90", "name": "2018957d-e361-4656-a49e-7af6f7dd0ec2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "29ea63e7-0679-4c22-8880-178658313e08"}}}]}, {"uuid": "1ecebcd9-1364-4d70-ad28-909bb5b9d8fa", "name": "load_p1rlv13044_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa31c772-8460-4624-a123-64b87ca8d332"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a9952cc1-e7a5-411b-bc2b-9b562df4ea90"}}}}, {"uuid": "72973c4b-1480-4f11-b02c-02b2e34a71c3", "name": "adebbaae-4278-4f65-999f-fd3d7c4d898c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.67656735172194, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8569955192100605, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b55a038b-402f-4d21-8478-cd30f0dffba0", "name": "5b690348-d90e-445d-8fed-7350db417d1e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72973c4b-1480-4f11-b02c-02b2e34a71c3"}}}]}, {"uuid": "abb52718-5636-4abc-9e4b-b1ad17398d48", "name": "load_p1rlv13044_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa31c772-8460-4624-a123-64b87ca8d332"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b55a038b-402f-4d21-8478-cd30f0dffba0"}}}}, {"uuid": "3627100b-bd13-4957-bf7f-5b3dcb399273", "name": "2f7e63ee-606e-4006-8054-fa280fed04a2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.927062407458527, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.5614641711041375, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9696f3af-6d44-4089-8061-b37461d4c4bf", "name": "dcca069b-2167-4bef-9609-3a4a5e037504", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3627100b-bd13-4957-bf7f-5b3dcb399273"}}}]}, {"uuid": "beb721c2-d839-4335-bb0b-504d29a38675", "name": "load_p1rlv13045_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6070414d-09e7-48a7-aec0-c105cc0f1a93"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9696f3af-6d44-4089-8061-b37461d4c4bf"}}}}, {"uuid": "23f1d753-acb9-4529-8473-9d9b923aae89", "name": "838a49c5-8699-4ad8-bef6-e7c55e73e980_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.927062407458527, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.5614641711041375, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9e38c316-0bf1-4c33-b03d-6c2bf7a7b6f4", "name": "8496860e-e0bc-4f29-904a-b4ae24142a88", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "23f1d753-acb9-4529-8473-9d9b923aae89"}}}]}, {"uuid": "39d37fbc-2cb3-45bc-8cf5-cd01fbc253ab", "name": "load_p1rlv13045_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6070414d-09e7-48a7-aec0-c105cc0f1a93"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9e38c316-0bf1-4c33-b03d-6c2bf7a7b6f4"}}}}, {"uuid": "3d8a2220-4e4f-4e81-9717-bb8186a3a84a", "name": "aaf7daa9-44e0-4720-816a-bd6211d51e77_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 15.279136617573831, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5014115237228067, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8fed5cf1-3790-4d6a-abea-a0cdedfcbf66", "name": "86e517e9-c448-4f71-a223-b4a9e03e56ca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3d8a2220-4e4f-4e81-9717-bb8186a3a84a"}}}]}, {"uuid": "d201c1a8-8405-407a-b693-d3e6ecbdfc3b", "name": "load_p1rlv13046_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5edc15fb-49d5-4052-8fad-4979578f6ed1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8fed5cf1-3790-4d6a-abea-a0cdedfcbf66"}}}}, {"uuid": "9693a4ba-33c3-4686-95d8-bd54caac41d7", "name": "192aec90-8be0-407e-8eb1-02d103b8aa8f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 15.279136617573831, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5014115237228067, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6101ba57-b6a3-4b6f-96e4-155b9aaec470", "name": "fa37179a-b466-4601-80e7-601e4e1ea5e6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9693a4ba-33c3-4686-95d8-bd54caac41d7"}}}]}, {"uuid": "c0555aca-c68c-4f8e-9f96-4d02f0aa6ac2", "name": "load_p1rlv13046_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5edc15fb-49d5-4052-8fad-4979578f6ed1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6101ba57-b6a3-4b6f-96e4-155b9aaec470"}}}}, {"uuid": "e4bb654e-d037-44c7-93fb-136954260713", "name": "aedd0946-c9f5-4c4e-9a2d-a162cffd94db_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3374419606114465, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8276898777002473, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "336d306b-9868-4071-b9ad-f2f0b5a68ee8", "name": "bf70eb87-479c-41be-acc2-1f40468a8d77", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e4bb654e-d037-44c7-93fb-136954260713"}}}]}, {"uuid": "a8845610-255f-4497-9140-7e0b22d0ea41", "name": "load_p1rlv13047_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4209bdad-276f-4e07-93e0-78b162ce95cf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "336d306b-9868-4071-b9ad-f2f0b5a68ee8"}}}}, {"uuid": "0e5dc84b-05ee-499d-b21a-da930b8ff0e7", "name": "0f30c492-a1c2-433d-932c-4fadbc3cda54_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3374419606114465, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8276898777002473, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fce9ecb2-402a-4b36-b60f-4380bc572ff2", "name": "97aad36b-aaba-4ba4-8b0f-69233cde3781", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0e5dc84b-05ee-499d-b21a-da930b8ff0e7"}}}]}, {"uuid": "ea5f208e-4405-479a-9249-fdd564e27ac7", "name": "load_p1rlv13047_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4209bdad-276f-4e07-93e0-78b162ce95cf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fce9ecb2-402a-4b36-b60f-4380bc572ff2"}}}}, {"uuid": "a2344f4d-580f-4d1f-8ca7-96074f3a11ca", "name": "ece2f7cf-fbf5-46d5-89e6-03413649b91b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3862445486686554, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0100117110086289, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2ab11757-34f2-4b89-b71a-6fdd1a84a1db", "name": "c0c1eaed-9da8-478f-a901-91ac11e47dd5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a2344f4d-580f-4d1f-8ca7-96074f3a11ca"}}}]}, {"uuid": "da3b6c00-95ce-4543-b2b6-ad5d48e8ed50", "name": "load_p1rlv13048_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "569078be-37c2-4c05-8455-91945eb7fdb9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2ab11757-34f2-4b89-b71a-6fdd1a84a1db"}}}}, {"uuid": "6ccf68b4-da02-4d62-aef9-3c67796369ee", "name": "216328c0-676a-4590-9934-5ddf303cf7d0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3862445486686554, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0100117110086289, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6c2cb862-2147-4b66-9321-30946bf3fddf", "name": "c93767ca-1ca8-472b-9e64-148c1794dace", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6ccf68b4-da02-4d62-aef9-3c67796369ee"}}}]}, {"uuid": "6fccad50-53ea-47b2-b9a4-c004ab2e0953", "name": "load_p1rlv13048_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "569078be-37c2-4c05-8455-91945eb7fdb9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6c2cb862-2147-4b66-9321-30946bf3fddf"}}}}, {"uuid": "88a28a37-de8a-40f3-85a8-ecf02873796a", "name": "8e5e686d-f46a-4930-adcf-16b20d576e59_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.734495706390117, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.8488351310797768, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "02143f59-781d-4f3c-ae65-f5cdf7219e27", "name": "a05253a1-6c79-4fe6-8718-0385e58be912", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "88a28a37-de8a-40f3-85a8-ecf02873796a"}}}]}, {"uuid": "f24deddc-0423-4117-9703-7a99a11e928c", "name": "load_p1rlv13049_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ed85192-4c5a-4c15-ba21-1ba883b03ddd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "02143f59-781d-4f3c-ae65-f5cdf7219e27"}}}}, {"uuid": "a1c08b21-8534-4b31-8cb2-a5d67b33899e", "name": "a63d29ec-7a7d-4e93-841b-a67584b88102_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.734495706390117, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.8488351310797768, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "620b6660-d420-44fc-a878-b0ce12065187", "name": "2326f173-a2c2-4284-84a3-088d473aad62", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a1c08b21-8534-4b31-8cb2-a5d67b33899e"}}}]}, {"uuid": "216972e7-f384-4784-97d7-16866891173d", "name": "load_p1rlv13049_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ed85192-4c5a-4c15-ba21-1ba883b03ddd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "620b6660-d420-44fc-a878-b0ce12065187"}}}}, {"uuid": "5330a24c-1c74-4447-91f5-72636276f9cc", "name": "7c121eb7-6fec-4992-bc39-b0896d5a6423_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 23.2179949774968, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.953694721257675, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6aa3263e-c151-4899-9e82-4a851d6b2b6d", "name": "7c121eb7-6fec-4992-bc39-b0896d5a6423_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 23.2179949774968, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.953694721257675, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c69ddaa1-e2dd-411d-9010-ab6cd872259d", "name": "7c121eb7-6fec-4992-bc39-b0896d5a6423_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 23.2179949774968, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.953694721257675, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "54f818ce-e227-429b-81c2-73c52d992eb5", "name": "0f41eb01-df7d-4d64-b994-d868d16dd02d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5330a24c-1c74-4447-91f5-72636276f9cc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6aa3263e-c151-4899-9e82-4a851d6b2b6d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c69ddaa1-e2dd-411d-9010-ab6cd872259d"}}}]}, {"uuid": "82e9cc65-bb9f-47af-8448-b3675c52f170", "name": "load_p1rlv13050", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "051eba03-4728-4626-8add-5410b5326dc7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "54f818ce-e227-429b-81c2-73c52d992eb5"}}}}, {"uuid": "3c5de08d-4489-4eff-9d3a-df139e6261fa", "name": "b6c5b2c4-f466-45a3-8919-d20bc877b7ca_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.295504020074436, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.753636562958712, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d96577ec-a347-4d9e-b275-74c4e3582e5a", "name": "c16beac3-a33a-4ec1-b3c2-6dd358eb7e26", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3c5de08d-4489-4eff-9d3a-df139e6261fa"}}}]}, {"uuid": "deba2370-2c00-4278-9e40-74318b254dc7", "name": "load_p1rlv13051_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9a855b0-538e-4fab-91f1-93b4ece09409"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d96577ec-a347-4d9e-b275-74c4e3582e5a"}}}}, {"uuid": "2277f042-b321-4549-85c5-bfeefe010c0f", "name": "05b5aa46-f5c1-46a7-a7be-a0916dc3e831_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.295504020074436, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.753636562958712, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "386bd9d3-bf89-4d7f-95d5-9484beb56654", "name": "9ff705f6-657e-4c3b-a184-d722838b010d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2277f042-b321-4549-85c5-bfeefe010c0f"}}}]}, {"uuid": "e9e13a15-8f79-48f8-b00d-112c0955c7ff", "name": "load_p1rlv13051_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9a855b0-538e-4fab-91f1-93b4ece09409"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "386bd9d3-bf89-4d7f-95d5-9484beb56654"}}}}, {"uuid": "e47fc9f6-a620-41d6-8e5e-a4dea78f1d8c", "name": "02707f24-6de0-4f61-9067-fc376ceb4c35_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 19.860755218124574, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.283352762304049, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "90d2a991-1be9-4d3d-b25c-d641f5852ce0", "name": "98b94bea-0497-48c9-83cf-43dc2f58673e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e47fc9f6-a620-41d6-8e5e-a4dea78f1d8c"}}}]}, {"uuid": "c45e9911-1996-4701-87fe-231c8d794fe3", "name": "load_p1rlv13052_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86d59550-d7c8-47e1-a6bc-14b2d50de58c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "90d2a991-1be9-4d3d-b25c-d641f5852ce0"}}}}, {"uuid": "0b19b038-939c-4e2e-8045-86bfef6c145a", "name": "b60560c0-d5ed-443f-ae13-4cc320357fa6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 19.860755218124574, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.283352762304049, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fe9ce19d-3988-4f6f-acf3-8ac26188214c", "name": "21ef59b3-9520-42d9-a4b4-7d46fe81973d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0b19b038-939c-4e2e-8045-86bfef6c145a"}}}]}, {"uuid": "94a58535-40fd-430f-a363-0df23068f8eb", "name": "load_p1rlv13052_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86d59550-d7c8-47e1-a6bc-14b2d50de58c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fe9ce19d-3988-4f6f-acf3-8ac26188214c"}}}}, {"uuid": "8c55e953-e9d0-4f9a-afda-2b8357ad3322", "name": "e5be8e83-343d-4fe3-bd2d-f1ea52abcf56_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.272941497663945, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5660410395064467, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ec02be12-6aad-48e2-a97a-42a76367cb01", "name": "f2b0c48e-02b6-40cf-8f81-327201ddb0b1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8c55e953-e9d0-4f9a-afda-2b8357ad3322"}}}]}, {"uuid": "b030444d-c176-4df9-93ed-356fa73af275", "name": "load_p1rlv13053_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e058437-0138-4305-a33e-d8fa61aed8cc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ec02be12-6aad-48e2-a97a-42a76367cb01"}}}}, {"uuid": "b9a4594e-ecff-4fe1-abef-288a6ec861c7", "name": "a5ccbeed-776c-4cb9-9e01-d994993b293b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.272941497663945, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5660410395064467, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c7e076c8-071b-44a4-82b9-3a65877b8dfa", "name": "4b5acf6d-494a-47de-ad73-bfda2139e333", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b9a4594e-ecff-4fe1-abef-288a6ec861c7"}}}]}, {"uuid": "2593ff8d-6b0c-41be-bf36-255ad70efd32", "name": "load_p1rlv13053_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e058437-0138-4305-a33e-d8fa61aed8cc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c7e076c8-071b-44a4-82b9-3a65877b8dfa"}}}}, {"uuid": "b0c56a5f-1836-4722-a7a7-f077bf3f4645", "name": "d029c9ef-058f-4751-b3cd-a83bf3b24772_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.124330522658403, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7653447086077897, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "98e6961c-f75a-4769-bfdd-47154e878802", "name": "5b818057-a251-4108-ba28-169f909cd66b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b0c56a5f-1836-4722-a7a7-f077bf3f4645"}}}]}, {"uuid": "9839d392-3d5d-4f32-8fb9-d9cdcecf9708", "name": "load_p1rlv13054_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21c6ea4f-ec9d-424e-8743-7175408f9e2c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "98e6961c-f75a-4769-bfdd-47154e878802"}}}}, {"uuid": "13880019-47f5-4b84-9104-ca8a4447df61", "name": "ddc63b09-7b10-4163-87cc-483774534e70_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.124330522658403, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7653447086077897, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "11e31fd7-ec52-4f61-9efb-5a0f0e2a8a45", "name": "cc0e63a9-f9df-434a-bbf6-394f9c1a79ac", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "13880019-47f5-4b84-9104-ca8a4447df61"}}}]}, {"uuid": "4e56214a-a749-4596-8cee-c667bf524484", "name": "load_p1rlv13054_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21c6ea4f-ec9d-424e-8743-7175408f9e2c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "11e31fd7-ec52-4f61-9efb-5a0f0e2a8a45"}}}}, {"uuid": "03c39f62-f346-4ecf-87da-b9ca705e9875", "name": "9928165b-4e5b-4c16-8a43-36d49a23f7a1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.470164086158317, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2411725730358465, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c5708940-7781-463f-bcd1-37b6c01a4cf1", "name": "9746de90-03dd-4bd0-9bcb-c40970aad705", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "03c39f62-f346-4ecf-87da-b9ca705e9875"}}}]}, {"uuid": "dbd96bdb-7497-4e12-a129-f75678931540", "name": "load_p1rlv13055_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387df3d3-5f03-47f4-8b16-bea8815e63d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c5708940-7781-463f-bcd1-37b6c01a4cf1"}}}}, {"uuid": "6f125292-8e7d-415c-87ba-4b4ba7d74463", "name": "b9af170a-b3b6-4e59-9859-9f671b00ecdb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.470164086158317, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2411725730358465, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c10703b2-a476-4671-9c7d-3bc15b542600", "name": "93dd0309-9f55-4a16-adda-c7157a769eac", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6f125292-8e7d-415c-87ba-4b4ba7d74463"}}}]}, {"uuid": "1cf14206-e3aa-4595-b8ce-69a46738d4b2", "name": "load_p1rlv13055_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387df3d3-5f03-47f4-8b16-bea8815e63d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c10703b2-a476-4671-9c7d-3bc15b542600"}}}}, {"uuid": "99c97419-8203-4111-ab56-df4a04e8149f", "name": "b93feca9-d48c-4c0c-b938-910cd5a29adf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.8145950466373417, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09093602970127403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f4184d92-ab07-4d9b-803f-435931250b82", "name": "ef23f723-a264-4e32-9a5d-84f6b35da717", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "99c97419-8203-4111-ab56-df4a04e8149f"}}}]}, {"uuid": "284761d0-ff7d-48c2-8436-493918426886", "name": "load_p1rlv13056_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16584dfd-537d-4b0d-a651-c73d0beabc6d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f4184d92-ab07-4d9b-803f-435931250b82"}}}}, {"uuid": "81b1de48-f250-4a8e-9b53-21944e42f4ed", "name": "70ec6cdc-04cb-4891-bdeb-6b8d57f70743_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.8145950466373417, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09093602970127403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "19359e76-6088-4b0e-8f47-c33f8a19d2f8", "name": "ace47199-3291-4db6-bc3b-65e5536c2fd6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "81b1de48-f250-4a8e-9b53-21944e42f4ed"}}}]}, {"uuid": "367c65ab-12a7-4272-8839-3190caeb0b1e", "name": "load_p1rlv13056_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16584dfd-537d-4b0d-a651-c73d0beabc6d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "19359e76-6088-4b0e-8f47-c33f8a19d2f8"}}}}, {"uuid": "6c5c1197-8967-44f0-85b2-dd43d1bf8829", "name": "fcb5b0f9-8055-434e-a248-0b9d1358fa16_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b535f1cc-a786-4654-808f-1f463aae6dc8", "name": "841c3407-202a-4de9-8727-64ed789e4708", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c5c1197-8967-44f0-85b2-dd43d1bf8829"}}}]}, {"uuid": "31c3c8e3-e973-44e8-8690-5b04d68c366f", "name": "load_p1rlv13057_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c63d163-75bd-4d91-bcfa-229a2e331b1f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b535f1cc-a786-4654-808f-1f463aae6dc8"}}}}, {"uuid": "79a4a57b-5123-4f98-8e18-1d35c301ddd6", "name": "bc86e892-aced-4a06-b06e-d828beeab8ac_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "85960692-2cde-4d5a-b06e-e13af7db5812", "name": "fb457142-7b1a-4c62-a316-43045a4c6b27", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "79a4a57b-5123-4f98-8e18-1d35c301ddd6"}}}]}, {"uuid": "fd8f7923-db76-49bc-a8a3-66b4445c641e", "name": "load_p1rlv13057_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c63d163-75bd-4d91-bcfa-229a2e331b1f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "85960692-2cde-4d5a-b06e-e13af7db5812"}}}}, {"uuid": "72ea28b0-b695-4847-8b76-01579e4b31e6", "name": "cd345cd3-f1ff-41f5-a1a3-c11ab919a3e8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.875608242018149, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1961787734858456, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e9e358ae-8ebc-4bbc-aacf-73d7af4f2b43", "name": "468eefb5-0eb9-4a7c-a496-c98bd42b4734", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72ea28b0-b695-4847-8b76-01579e4b31e6"}}}]}, {"uuid": "a5e733fd-c2a1-42ae-a63b-4b11bfa9d4ad", "name": "load_p1rlv13058_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c83997dc-872f-494f-8c8a-7266c854fc48"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e9e358ae-8ebc-4bbc-aacf-73d7af4f2b43"}}}}, {"uuid": "fa7d9d10-6d78-4c79-8731-d4c36a133c7b", "name": "7d9a7113-b197-45a8-88c4-551125329b8a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.875608242018149, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1961787734858456, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7d1c59aa-705c-45c6-b82f-b7178e590441", "name": "a3343969-c521-4491-8340-33b943ea446a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fa7d9d10-6d78-4c79-8731-d4c36a133c7b"}}}]}, {"uuid": "fbd1c302-0e7e-41ea-8740-e1992463426f", "name": "load_p1rlv13058_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c83997dc-872f-494f-8c8a-7266c854fc48"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7d1c59aa-705c-45c6-b82f-b7178e590441"}}}}, {"uuid": "f0d8f92a-2aa8-4431-b312-ceb670228bc3", "name": "6e80263e-b0f6-4134-8069-1f1b7dbdc9d0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.516258392707745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.82351986644914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8d6d47de-9c11-42bd-853a-3d70debb739a", "name": "d4eb75ca-db27-4f11-a549-7e032883373b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f0d8f92a-2aa8-4431-b312-ceb670228bc3"}}}]}, {"uuid": "1c110a7c-5cdc-43a4-b1f8-747810ee5d26", "name": "load_p1rlv13059_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a1779b5b-1a6c-4511-9d4b-88026b430173"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8d6d47de-9c11-42bd-853a-3d70debb739a"}}}}, {"uuid": "8392a5f2-8483-4178-8754-587db4aabfb1", "name": "f1e5901c-94b7-463f-9101-552c870f7ba5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.516258392707745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.82351986644914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "818d8732-8073-4359-aa2a-4354c7097e22", "name": "3fd08c63-7fde-40fd-9774-52d88dda9756", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8392a5f2-8483-4178-8754-587db4aabfb1"}}}]}, {"uuid": "baecbf82-3a54-4bec-8e4f-b5150a2aaa5c", "name": "load_p1rlv13059_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a1779b5b-1a6c-4511-9d4b-88026b430173"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "818d8732-8073-4359-aa2a-4354c7097e22"}}}}, {"uuid": "4a61925b-63ad-4878-bc40-638e85e45994", "name": "5aa02a8b-c7a8-436e-a0a9-b6678a5c7f62_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3225810719994042, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7007930471414398, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1bfb56c0-4096-4c8c-8132-c0d23ee1f565", "name": "a962c033-de0a-49a5-938a-78efb020e111", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4a61925b-63ad-4878-bc40-638e85e45994"}}}]}, {"uuid": "a20be27f-4923-49db-83c7-31bc05844f05", "name": "load_p1rlv13060_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8767a040-da31-48d9-9473-0941856bcedc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1bfb56c0-4096-4c8c-8132-c0d23ee1f565"}}}}, {"uuid": "a0650809-8db7-442f-9baf-4b1823c29dac", "name": "11a2873e-9d09-40a4-88ec-071c2a439041_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3225810719994042, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7007930471414398, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "11e7c63b-d762-436a-ab74-35f68452aa97", "name": "c22d50fb-5daa-45ee-ae34-1913bc061277", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a0650809-8db7-442f-9baf-4b1823c29dac"}}}]}, {"uuid": "54f04642-4939-42fd-84ee-dc703d2e192c", "name": "load_p1rlv13060_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8767a040-da31-48d9-9473-0941856bcedc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "11e7c63b-d762-436a-ab74-35f68452aa97"}}}}, {"uuid": "f09616a9-d057-472b-be37-d3dde12abaa4", "name": "6818e893-548b-4084-ab88-2c7a3f9b4ae8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.20841006074213, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.2893238389393127, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "05d08ee4-9edf-462f-ab42-6f6ab946315a", "name": "6818e893-548b-4084-ab88-2c7a3f9b4ae8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.20841006074213, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.2893238389393127, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5b5f5f56-b919-4163-9f77-d0372d0dfc9c", "name": "6818e893-548b-4084-ab88-2c7a3f9b4ae8_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.20841006074213, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.2893238389393127, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7cbd7f03-3a65-4248-ac54-402c42382bd1", "name": "18abeb5f-69d6-4190-8139-c09f1ecb7b47", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f09616a9-d057-472b-be37-d3dde12abaa4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "05d08ee4-9edf-462f-ab42-6f6ab946315a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b5f5f56-b919-4163-9f77-d0372d0dfc9c"}}}]}, {"uuid": "aefdeb5a-7e28-4e59-a971-9e1880d00e58", "name": "load_p1rlv13061", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d46fd47-37f5-48a0-ba0d-d0746e6e6da3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7cbd7f03-3a65-4248-ac54-402c42382bd1"}}}}, {"uuid": "6a5e0cda-f071-41b3-89c3-bc3895ae79fd", "name": "0d619baf-e5ab-4247-ae0b-9be1dc720473_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c7020c42-d410-4138-b783-2833e5b95e5d", "name": "99999fa5-08e3-4da4-a649-53dbbd1068f7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6a5e0cda-f071-41b3-89c3-bc3895ae79fd"}}}]}, {"uuid": "95215704-3da1-4ebf-82f9-6059829ad086", "name": "load_p1rlv13062_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d2fa164-4c03-4bcd-a386-749ccd4e9001"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c7020c42-d410-4138-b783-2833e5b95e5d"}}}}, {"uuid": "46910cb5-2278-4ebc-b869-a4176999f6a2", "name": "8019d56f-4594-4922-9645-636324369ed9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "80fc95da-435d-45a0-a2c9-560a5a2f6aa0", "name": "27053b5a-0961-4ef7-a1fc-1cd4ecca27c1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "46910cb5-2278-4ebc-b869-a4176999f6a2"}}}]}, {"uuid": "b9c24b71-6e11-4019-8154-506058e4c412", "name": "load_p1rlv13062_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d2fa164-4c03-4bcd-a386-749ccd4e9001"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "80fc95da-435d-45a0-a2c9-560a5a2f6aa0"}}}}, {"uuid": "f455affc-aa35-47f2-9204-d82535afe51e", "name": "f7144831-4e15-4ed2-aedc-52b063299ed5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7083181921938193, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5666922324635131, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d410a840-d501-424e-866e-c57fd35ed41b", "name": "62e4edf4-f84f-4ca5-b758-65ce2968d898", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f455affc-aa35-47f2-9204-d82535afe51e"}}}]}, {"uuid": "e1bdea92-19fa-4287-b18d-26335d377399", "name": "load_p1rlv13185_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c29c3206-b71d-41d1-8ad7-a693c8c25d4d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d410a840-d501-424e-866e-c57fd35ed41b"}}}}, {"uuid": "2e60e5d6-561c-42b0-8601-c04b7998b6c8", "name": "352fe72c-c94f-441e-84ce-c82499836e28_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7083181921938193, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5666922324635131, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f4f3c19-5175-404f-9c92-e25705eb2ba8", "name": "defe891f-b26d-4dbc-9a31-c5346d2e5ce6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2e60e5d6-561c-42b0-8601-c04b7998b6c8"}}}]}, {"uuid": "38d145c4-18bd-4d9e-a258-5ecd2fd7429b", "name": "load_p1rlv13185_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c29c3206-b71d-41d1-8ad7-a693c8c25d4d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f4f3c19-5175-404f-9c92-e25705eb2ba8"}}}}, {"uuid": "cb8dd4b9-478e-47ca-9faa-4093149e4ba4", "name": "6d4551ec-1524-4d41-a79c-0698ba79ae98_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.774034588817963, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.005441618856208, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0367dad2-f61f-42d8-84b1-beb3a9f41e18", "name": "7ec19d5f-61eb-4752-b91e-7418eebc93a8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cb8dd4b9-478e-47ca-9faa-4093149e4ba4"}}}]}, {"uuid": "c488ff8d-b283-48e1-926a-a87c8c8c974d", "name": "load_p1rlv13187_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ffbd17b6-b1a2-4e55-9052-67a84419bb9d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0367dad2-f61f-42d8-84b1-beb3a9f41e18"}}}}, {"uuid": "44ac4961-909d-4886-bad7-ad68cddce4d2", "name": "b5cd8e31-7da9-43c0-a8b3-2d09ba56c7c0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.774034588817963, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.005441618856208, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "71866af3-3b03-49b5-8ed8-2fcb0c02fb5d", "name": "0a7ca848-f6e4-4330-b1ba-bcc12a3de282", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "44ac4961-909d-4886-bad7-ad68cddce4d2"}}}]}, {"uuid": "7f56d7c7-f838-4fcb-89c1-2d348c29a4c7", "name": "load_p1rlv13187_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ffbd17b6-b1a2-4e55-9052-67a84419bb9d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "71866af3-3b03-49b5-8ed8-2fcb0c02fb5d"}}}}, {"uuid": "90accc6c-537a-4e94-b3d9-599bc4d64d05", "name": "4038a0af-b705-4717-9396-d519d296d2bd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.028781788264419, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6709073147144231, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1f1260f7-8479-4de9-9e97-75aad039f9d2", "name": "b06a4187-870a-460c-b8eb-49f511949b47", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "90accc6c-537a-4e94-b3d9-599bc4d64d05"}}}]}, {"uuid": "abb8d875-6105-4ed3-8a3c-c50530500a31", "name": "load_p1rlv13188_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67ffcd9f-ba90-4da7-b3b6-46310e321590"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1f1260f7-8479-4de9-9e97-75aad039f9d2"}}}}, {"uuid": "3ed24d70-5c45-4cd8-92ce-2d822e741459", "name": "e40b61a4-2e7d-42de-a2ec-5134d7e60e86_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.028781788264419, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6709073147144231, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "66d43c17-fd3c-4cff-beed-d3cf878028df", "name": "908786ce-d194-4c28-a6cb-a687c3d12f93", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3ed24d70-5c45-4cd8-92ce-2d822e741459"}}}]}, {"uuid": "9719e5cb-9795-4a7a-bdea-f89f7f132c4c", "name": "load_p1rlv13188_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67ffcd9f-ba90-4da7-b3b6-46310e321590"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "66d43c17-fd3c-4cff-beed-d3cf878028df"}}}}, {"uuid": "749e6bd0-8c6d-4d4f-be52-4afd163f1e24", "name": "c9a3c089-66dc-4582-8ede-10c963e974e4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6702758059963014, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.7275069224848631, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dab591e8-b136-4923-a683-e9971efb1b7c", "name": "3fa3ab7c-8f40-43ca-9727-3fbeca5f3e7b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "749e6bd0-8c6d-4d4f-be52-4afd163f1e24"}}}]}, {"uuid": "7d6f4ffd-ea62-44ad-940b-8f4102b7b3c6", "name": "load_p1rlv13189_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "268361f6-d5ac-4002-80a6-f56f3b33599c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dab591e8-b136-4923-a683-e9971efb1b7c"}}}}, {"uuid": "9a5cacf7-835a-49cf-acd7-b750f5c58c18", "name": "ab341bf9-86dc-4140-a854-37cb7399eacb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6702758059963014, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.7275069224848631, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1012a10a-56cf-4ac9-9911-897ba8019bfb", "name": "44268273-eb53-429a-8f44-2a6a4a41b061", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9a5cacf7-835a-49cf-acd7-b750f5c58c18"}}}]}, {"uuid": "bca953e6-f28c-436e-b66c-e5009a64a975", "name": "load_p1rlv13189_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "268361f6-d5ac-4002-80a6-f56f3b33599c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1012a10a-56cf-4ac9-9911-897ba8019bfb"}}}}, {"uuid": "395a2561-b788-4737-9b64-e078b6546749", "name": "e3699a39-4ba1-4a3c-bf6d-2e51ffb98753_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.667455481738122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8122169683202977, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "35ed602a-8684-4906-8cc5-28d4667ee3d0", "name": "fecd8dfc-615e-4e60-aa7f-ad1c564bd08e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "395a2561-b788-4737-9b64-e078b6546749"}}}]}, {"uuid": "a2a392ac-8ce7-4c1f-89fb-f905f3fcfbc4", "name": "load_p1rlv13190_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3dbc593c-3949-4fa4-8738-d92540dbf998"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "35ed602a-8684-4906-8cc5-28d4667ee3d0"}}}}, {"uuid": "fafb4c38-c350-42f5-b9bf-65b115e4be2a", "name": "75db384a-c407-4fe0-b583-acac860ef089_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.667455481738122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8122169683202977, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "edb4253e-fdd3-411f-990e-16e38c36492c", "name": "5fca91c1-9303-45b0-9c0a-6a572f1e48a2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fafb4c38-c350-42f5-b9bf-65b115e4be2a"}}}]}, {"uuid": "f2da2ffb-270d-4757-bbf1-9064b5ccbad5", "name": "load_p1rlv13190_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3dbc593c-3949-4fa4-8738-d92540dbf998"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "edb4253e-fdd3-411f-990e-16e38c36492c"}}}}, {"uuid": "15e0ada5-9a29-4e07-97ec-108affc305b4", "name": "500052cb-f666-4032-a2b2-bab8b21a3486_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.921717825926216, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5520868751081406, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "34f6ee7b-b630-4c41-93d1-81d672c2eb6a", "name": "d32ebdcd-458d-46eb-809d-09c340eac5ad", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "15e0ada5-9a29-4e07-97ec-108affc305b4"}}}]}, {"uuid": "6ef49a1a-54aa-4ea5-b8ec-a869524870c2", "name": "load_p1rlv13191_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f6d09e9-3592-4560-8626-0d7cb71ca56a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "34f6ee7b-b630-4c41-93d1-81d672c2eb6a"}}}}, {"uuid": "b91f19a4-1fa5-42e2-bc4c-63d94394b78b", "name": "293b3bea-f770-484c-af08-4aa060d931cf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.921717825926216, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5520868751081406, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "21b89c3c-7d8f-44f2-be4c-2729adb154b6", "name": "855faf25-9d72-460b-81f3-1f2d5b31611a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b91f19a4-1fa5-42e2-bc4c-63d94394b78b"}}}]}, {"uuid": "13399b76-ec3f-4106-959d-3a94f7c1ce5f", "name": "load_p1rlv13191_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f6d09e9-3592-4560-8626-0d7cb71ca56a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "21b89c3c-7d8f-44f2-be4c-2729adb154b6"}}}}, {"uuid": "9feed621-db52-4acd-aa85-7f7d9f2ec289", "name": "cdbb55a3-b472-4d02-925d-3f772077109b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5300176124233262, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6781680527999017, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "048611e6-65d1-4c10-a692-96661c2a8918", "name": "d17a7a92-cbd8-4c79-9bdc-cc7740946c9b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9feed621-db52-4acd-aa85-7f7d9f2ec289"}}}]}, {"uuid": "4f0ccd3a-8be6-405b-985a-749cf90427ca", "name": "load_p1rlv13194_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d5ba889-d8f7-44ca-86b2-40939fa95df2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "048611e6-65d1-4c10-a692-96661c2a8918"}}}}, {"uuid": "2475c74c-94c4-46d5-8d6d-bac499071094", "name": "8e9d3c6d-fe0b-4f56-bb2b-6ce8739d7903_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5300176124233262, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6781680527999017, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "adda3498-b470-40e0-ad6d-84898623c771", "name": "d70c74cf-2de6-4495-8cb0-9eb84d9b96d0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2475c74c-94c4-46d5-8d6d-bac499071094"}}}]}, {"uuid": "e20cfae8-25b8-4116-9fe0-d5f20ebe404a", "name": "load_p1rlv13194_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d5ba889-d8f7-44ca-86b2-40939fa95df2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "adda3498-b470-40e0-ad6d-84898623c771"}}}}, {"uuid": "bbf7c688-0003-4d2e-8ecd-7359df36e721", "name": "c3def5f5-ec1e-4744-82c5-7166a5e86bde_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5670847441713207, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5540004468841006, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4abf7b78-c528-4955-94e5-48b90677531d", "name": "7880990d-bbf5-4fb9-98dc-41446ae0eaa8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bbf7c688-0003-4d2e-8ecd-7359df36e721"}}}]}, {"uuid": "5edc1716-e850-46c9-a684-263e46e62c9f", "name": "load_p1rlv13195_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e3e10c6-6ce2-4efa-be50-80e8b9bffe29"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4abf7b78-c528-4955-94e5-48b90677531d"}}}}, {"uuid": "02148270-d3f4-4c59-a2db-180eaa5f6e7d", "name": "0ab68643-d170-4d11-9c01-c0b81c3e2af2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5670847441713207, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5540004468841006, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2c5372b0-f45f-4a43-85e2-dde672b97a62", "name": "d1c9efd6-80e1-43dc-8b93-a1edd8d4263f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "02148270-d3f4-4c59-a2db-180eaa5f6e7d"}}}]}, {"uuid": "490acbcf-dec4-4965-9313-3498325efe09", "name": "load_p1rlv13195_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e3e10c6-6ce2-4efa-be50-80e8b9bffe29"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2c5372b0-f45f-4a43-85e2-dde672b97a62"}}}}, {"uuid": "6ae648fb-d09e-4c41-87e0-ca3a8d0da424", "name": "43c5e241-13d0-45b1-bce1-197bff3fa4ed_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.565985425671141, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8139237791533422, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "16e574a4-551a-4860-bf7f-1b8f4617b7ab", "name": "2875abd9-9f4b-4fcc-a8c8-6c53d49e4ae6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6ae648fb-d09e-4c41-87e0-ca3a8d0da424"}}}]}, {"uuid": "44c680a2-9eeb-4116-b0d5-0e2bba96cec1", "name": "load_p1rlv13196_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27013147-3d8f-4d75-a7a7-24457dc6d62a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "16e574a4-551a-4860-bf7f-1b8f4617b7ab"}}}}, {"uuid": "68149fca-3636-4d63-9aaf-a9776af7b4e5", "name": "7b062a3e-0dc2-44f1-8468-4e827b78a170_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.565985425671141, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8139237791533422, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "39d7fb73-eecd-4c90-a1b8-eea91fa80906", "name": "e2a1874f-f68a-4327-92c9-7c5bd349cba2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "68149fca-3636-4d63-9aaf-a9776af7b4e5"}}}]}, {"uuid": "18e6f764-9dc2-401a-aca6-387a640cb498", "name": "load_p1rlv13196_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27013147-3d8f-4d75-a7a7-24457dc6d62a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "39d7fb73-eecd-4c90-a1b8-eea91fa80906"}}}}, {"uuid": "cd3bf1f7-178e-4e37-af1c-71ee3fda84e2", "name": "8676102d-bd6e-4b64-8139-35261d0b516a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.88875250566531, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3533612733571443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3cb4cecc-fd03-46ca-8a7a-11f6d3c25706", "name": "6f4eef1e-5b06-427a-84e7-3dff9c0dd9ce", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cd3bf1f7-178e-4e37-af1c-71ee3fda84e2"}}}]}, {"uuid": "86dc39cd-37d2-4751-b049-62efd6d1d044", "name": "load_p1rlv13197_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b077d0f-74ec-4a04-8eb8-cf02ad16077d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3cb4cecc-fd03-46ca-8a7a-11f6d3c25706"}}}}, {"uuid": "00470f98-ca1d-4fe8-9eed-62ae6a5acb98", "name": "d9e8a415-8eb6-413a-bf6d-0d82fe874249_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.88875250566531, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3533612733571443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2d6ec1b4-1f84-43d0-a8f9-f697149b8cd9", "name": "65b56eab-9f11-4f42-820b-a98de379bc18", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "00470f98-ca1d-4fe8-9eed-62ae6a5acb98"}}}]}, {"uuid": "4941ce80-fbd4-4920-9b61-4a7973328dd5", "name": "load_p1rlv13197_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b077d0f-74ec-4a04-8eb8-cf02ad16077d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2d6ec1b4-1f84-43d0-a8f9-f697149b8cd9"}}}}, {"uuid": "d2d312dd-e429-44ee-b1da-478fe98a0d04", "name": "6b12e10f-4c38-48df-8729-363a813877c5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5401800544546385, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5525745253976501, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0e2ff513-8470-4dd8-bb10-1303f457ef6d", "name": "a4a5ac02-22f4-4b08-aa51-dd56d2eb35b5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d2d312dd-e429-44ee-b1da-478fe98a0d04"}}}]}, {"uuid": "ab52a8d9-56d7-4505-96f6-43958c808cbb", "name": "load_p1rlv13199_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad7545fb-8a41-4ed7-a178-e90f19bfa9d5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0e2ff513-8470-4dd8-bb10-1303f457ef6d"}}}}, {"uuid": "f5108d12-4535-409d-89cf-f89b367b6bb8", "name": "0c23895e-b538-43eb-9188-29f3b222bf8a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5401800544546385, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5525745253976501, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4024c612-bd14-466c-99e8-09f9b24f32bb", "name": "c2842eae-ba25-4847-bfa8-2fc534e875b6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f5108d12-4535-409d-89cf-f89b367b6bb8"}}}]}, {"uuid": "680b353e-4b9e-4cfd-8563-474184c7c4a4", "name": "load_p1rlv13199_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad7545fb-8a41-4ed7-a178-e90f19bfa9d5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4024c612-bd14-466c-99e8-09f9b24f32bb"}}}}, {"uuid": "5836d2d8-73bf-4713-aa19-2ebdb75d814e", "name": "3aa35252-4a62-4093-a046-1f26b5cccc96_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4622944887503224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10483650830237357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f3830231-d432-4ea1-a877-c43e1eb23c26", "name": "4406571f-ea0c-40d5-a95f-1d6ff0358e22", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5836d2d8-73bf-4713-aa19-2ebdb75d814e"}}}]}, {"uuid": "0cdce4ca-4ae0-4ef2-ab2e-21943cabf260", "name": "load_p1rlv13200_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fed30a3f-12a5-4545-b5d5-5c13a131a256"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f3830231-d432-4ea1-a877-c43e1eb23c26"}}}}, {"uuid": "24e9efc8-e540-453e-9c06-acb8376f8c87", "name": "e00d3e41-118b-4b67-9282-585e3a1062a6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4622944887503224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10483650830237357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e3e004c0-59f7-4008-bfc3-b21a8a3c2ec1", "name": "e944d3f7-b958-4ad8-babc-f3b650222041", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "24e9efc8-e540-453e-9c06-acb8376f8c87"}}}]}, {"uuid": "5cbfb4b6-8fe8-4226-9c2b-6a740d74a7dc", "name": "load_p1rlv13200_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fed30a3f-12a5-4545-b5d5-5c13a131a256"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e3e004c0-59f7-4008-bfc3-b21a8a3c2ec1"}}}}, {"uuid": "bf2b6285-13cf-417c-9019-df8d6d921784", "name": "72893fec-4075-4f0c-8439-ec735f3c3781_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.195601026095605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4379463760124337, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0690c0af-36e8-4faf-9931-a3452f52186f", "name": "b34d8a4c-b257-436f-8c55-a9c836295b91", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bf2b6285-13cf-417c-9019-df8d6d921784"}}}]}, {"uuid": "3c26dedc-4fc5-4269-ac0d-51bb1fe00d43", "name": "load_p1rlv13201_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cdd7c49-e758-4009-8db5-d0b5748f919c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0690c0af-36e8-4faf-9931-a3452f52186f"}}}}, {"uuid": "0381ba9f-4f61-4e8b-8f3e-33df9c63f2be", "name": "9255e6bf-8dac-41ed-818f-a3af6456b1a5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.195601026095605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4379463760124337, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1bb6d719-9f60-4715-acf7-328790d4356c", "name": "9c0ddcdd-a56e-4be5-a7dd-f0299fc3231b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0381ba9f-4f61-4e8b-8f3e-33df9c63f2be"}}}]}, {"uuid": "95beee2e-b0cd-4efd-a08f-b5aa0d3b96a2", "name": "load_p1rlv13201_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cdd7c49-e758-4009-8db5-d0b5748f919c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1bb6d719-9f60-4715-acf7-328790d4356c"}}}}, {"uuid": "f03edf52-7271-4a3e-ae1f-53a895760067", "name": "acb7d454-6f87-41e9-9a36-d2c551b386b6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8140414184691503, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34693077623207685, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7fe60fff-7fd7-4d9d-9182-8c33ae3cc32f", "name": "dab218dc-48d1-42fd-97bc-69e46edfd8ee", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f03edf52-7271-4a3e-ae1f-53a895760067"}}}]}, {"uuid": "9702e0ce-9c9a-4469-a0a1-a78d4c62d7f2", "name": "load_p1rlv13316_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473b080b-1412-40dc-a452-09d43a462098"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7fe60fff-7fd7-4d9d-9182-8c33ae3cc32f"}}}}, {"uuid": "3d64967f-5c6c-4c44-baff-4cea9d9023d4", "name": "ee63e168-4c6b-458f-9279-3f5f3a415f27_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8140414184691503, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34693077623207685, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d71051fc-5760-4907-b6d4-890667fc0d5b", "name": "048ee0ab-8d53-47d7-b9ed-62a8e4068d7b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3d64967f-5c6c-4c44-baff-4cea9d9023d4"}}}]}, {"uuid": "b6dbfe6e-a255-4b3a-b58c-e03141eab622", "name": "load_p1rlv13316_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473b080b-1412-40dc-a452-09d43a462098"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d71051fc-5760-4907-b6d4-890667fc0d5b"}}}}, {"uuid": "dac1c5ce-10b4-4584-9591-5e05bef98c5d", "name": "937de26d-9b11-4d11-ab4a-279351ae6c89_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a0c87f0-5315-4a11-85e7-c6b554c99a2b", "name": "fcf85268-ac67-4816-9093-b27b458df88f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dac1c5ce-10b4-4584-9591-5e05bef98c5d"}}}]}, {"uuid": "edc77fc3-e069-4d18-96c9-61760d32f742", "name": "load_p1rlv13597_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "353889fb-da44-4cf8-ae0e-d20541f36d7e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0a0c87f0-5315-4a11-85e7-c6b554c99a2b"}}}}, {"uuid": "26e8b0dc-2ac3-4742-ac43-55c0bb67b561", "name": "e0a5dbc6-77a6-4835-998c-1543298e0f8f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d9e348bd-8fff-4da1-98f1-8a90ff9da829", "name": "7ac170e6-bc12-4fef-b7e3-5c414b03ece6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "26e8b0dc-2ac3-4742-ac43-55c0bb67b561"}}}]}, {"uuid": "1d33447a-cabc-4c04-8811-f06c7603e54e", "name": "load_p1rlv13597_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "353889fb-da44-4cf8-ae0e-d20541f36d7e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d9e348bd-8fff-4da1-98f1-8a90ff9da829"}}}}, {"uuid": "37c4d4ed-d4bc-46ee-b908-0a71a5aa6518", "name": "800bea90-02ed-4d86-a2d7-34d14bf5aad6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "041a363b-8459-4191-a6f5-4685aeb8936b", "name": "ecc00417-30b1-427f-a6f3-81ae9febefaf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "37c4d4ed-d4bc-46ee-b908-0a71a5aa6518"}}}]}, {"uuid": "6033b316-93cf-415e-841e-82f4e21dbc25", "name": "load_p1rlv13598_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59953c2f-244e-4bb8-ab24-b28d82b195e1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "041a363b-8459-4191-a6f5-4685aeb8936b"}}}}, {"uuid": "c7f4cc2e-d190-4b9b-82c7-99a025144f6e", "name": "3e28f879-bbd7-4454-b56a-0e32fb67f207_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4913cce6-590b-4348-900a-b797faf546fd", "name": "20331403-4b6e-4cf2-837a-2862b0536e98", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c7f4cc2e-d190-4b9b-82c7-99a025144f6e"}}}]}, {"uuid": "63dca524-7496-41cc-9c8c-adcfbbe727bc", "name": "load_p1rlv13598_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59953c2f-244e-4bb8-ab24-b28d82b195e1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4913cce6-590b-4348-900a-b797faf546fd"}}}}, {"uuid": "c88ab96a-c49c-422b-bfd3-498b6fc68c01", "name": "1e50911e-2f5c-4f91-8819-6bbb0a799416_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cb268438-07b7-4715-968d-4f6ab65bcc52", "name": "49bf7cd1-6dfb-4119-b3d1-0f9ba6162d72", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c88ab96a-c49c-422b-bfd3-498b6fc68c01"}}}]}, {"uuid": "9be21e16-3c8d-4128-ab14-c6911cd8c684", "name": "load_p1rlv13599_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2a60818-4310-4100-9aa8-35ef37aa5f40"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cb268438-07b7-4715-968d-4f6ab65bcc52"}}}}, {"uuid": "bfcd7e85-efbc-4cfa-b47b-9ae669d6966c", "name": "bc0bb68d-ed14-4e89-9996-9bb3483c92c5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5e70eb0d-153f-4fb3-a538-2b0c4a1dc9fc", "name": "c3e6a5e6-3a47-4917-9dba-1bb6074677eb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bfcd7e85-efbc-4cfa-b47b-9ae669d6966c"}}}]}, {"uuid": "bdc775ec-84d1-4a2c-bb98-c1e19e71da3c", "name": "load_p1rlv13599_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2a60818-4310-4100-9aa8-35ef37aa5f40"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5e70eb0d-153f-4fb3-a538-2b0c4a1dc9fc"}}}}, {"uuid": "86a1a85e-300d-4da9-84ff-1fe5a2e5461f", "name": "c7009d2b-05c2-440b-b854-afa1d3a88ecb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.940151571607843, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7360323556900852, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3b91ff6a-d898-4df2-b1d2-53ce9e03bb81", "name": "348b7989-2c3f-46ef-b687-739cb14395a3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "86a1a85e-300d-4da9-84ff-1fe5a2e5461f"}}}]}, {"uuid": "e17443e8-f800-420d-803b-6bd11600508f", "name": "load_p1rlv13600_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59ab6d81-a91c-4350-8f94-abe02e3e1555"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3b91ff6a-d898-4df2-b1d2-53ce9e03bb81"}}}}, {"uuid": "34d0ec8c-f568-4d5b-81ed-0a449f709d4e", "name": "61bad4c4-8759-486c-8089-62cce9f8522a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.940151571607843, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7360323556900852, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "928b9698-5fd4-4dcb-b44f-e91ba1da74bc", "name": "e1242757-0cfe-4113-96b9-c8744221d741", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "34d0ec8c-f568-4d5b-81ed-0a449f709d4e"}}}]}, {"uuid": "7ecbba76-6fc2-4902-8f7e-ed8a8223ba90", "name": "load_p1rlv13600_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59ab6d81-a91c-4350-8f94-abe02e3e1555"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "928b9698-5fd4-4dcb-b44f-e91ba1da74bc"}}}}, {"uuid": "95ebc42e-d8ed-4efc-9e8d-d01fdf170ded", "name": "0ceedc81-bfb3-4288-961c-0e49525bf1d9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.872515319591797, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7328111219910317, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bf6f99c3-a9c4-4e4b-820c-a2e12bfe4966", "name": "f3195a99-0a13-4b39-8ab3-dc1c65446089", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "95ebc42e-d8ed-4efc-9e8d-d01fdf170ded"}}}]}, {"uuid": "fb643b41-122e-4bf0-b101-29d55e2bc232", "name": "load_p1rlv13601_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91953a27-bbc7-494a-bec2-a12b4c0f6af6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bf6f99c3-a9c4-4e4b-820c-a2e12bfe4966"}}}}, {"uuid": "07ad6e5f-b4ba-43fc-8288-53ecc9792bdd", "name": "b9747aa8-2e9e-4db4-94d7-2b04e560536a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.872515319591797, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7328111219910317, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "51667fa2-0da1-4cca-ad8a-6a60cfc43683", "name": "4cef8fd1-a3ff-4f2b-abb8-d9bcf4da4242", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "07ad6e5f-b4ba-43fc-8288-53ecc9792bdd"}}}]}, {"uuid": "b5b4f2e8-4da2-4bb5-9f06-43efb167b2a9", "name": "load_p1rlv13601_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91953a27-bbc7-494a-bec2-a12b4c0f6af6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "51667fa2-0da1-4cca-ad8a-6a60cfc43683"}}}}, {"uuid": "ea1ce7af-6d0a-423b-bc32-74905847c262", "name": "b61e5da4-890c-407d-a6f0-8fd358dda581_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.308477864741614, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307751830484037, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a45011c6-1d24-462b-99f0-9537120e1f35", "name": "614283b0-7844-438c-9863-4124f7dfc777", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ea1ce7af-6d0a-423b-bc32-74905847c262"}}}]}, {"uuid": "5402fdc5-a823-41d7-9db4-622ed2bf74bf", "name": "load_p1rlv13604_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9b83bdf-b564-4997-bfc7-1be2f2e58199"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a45011c6-1d24-462b-99f0-9537120e1f35"}}}}, {"uuid": "7378b82f-38ce-4c28-a550-c37b78d7b46c", "name": "86fa24a9-15a6-4d02-b561-bb5e1e8eba63_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.308477864741614, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307751830484037, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "13368055-1611-4a68-a552-3ecc6be93c50", "name": "58a60a73-ac22-4a59-9aa9-d024c3804259", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7378b82f-38ce-4c28-a550-c37b78d7b46c"}}}]}, {"uuid": "6c4e0cf3-fbb2-48bd-a319-e909a6b7afdc", "name": "load_p1rlv13604_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9b83bdf-b564-4997-bfc7-1be2f2e58199"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "13368055-1611-4a68-a552-3ecc6be93c50"}}}}, {"uuid": "96374ea5-49ab-4bb4-9b0f-e042b6f86caf", "name": "d2525f13-738e-4d5c-8557-092bc2a7aea9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0263288002917053, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.546221099657035, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6ac379df-438b-4c9a-9cee-907cb9ac2b96", "name": "d690a139-4ae2-45e1-9f14-79bf3d186cd3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "96374ea5-49ab-4bb4-9b0f-e042b6f86caf"}}}]}, {"uuid": "aa4e9307-1124-451d-bab1-24bd64df40db", "name": "load_p1rlv13605_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c39dc6f1-08b5-4bc1-a6ae-be0076af56aa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6ac379df-438b-4c9a-9cee-907cb9ac2b96"}}}}, {"uuid": "30529f9d-37bc-4c22-9856-0356ce450b19", "name": "2d6e29aa-c304-4568-a7ce-9e4ceaebc081_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0263288002917053, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.546221099657035, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "232736c1-342b-4abb-815a-85de36131904", "name": "cbb570ad-e05a-49e4-af04-6f5c1e6881c1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "30529f9d-37bc-4c22-9856-0356ce450b19"}}}]}, {"uuid": "88f60a05-1c81-46dc-b19b-d233db420470", "name": "load_p1rlv13605_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c39dc6f1-08b5-4bc1-a6ae-be0076af56aa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "232736c1-342b-4abb-815a-85de36131904"}}}}, {"uuid": "263e7d44-927e-42de-9b33-bc043e89c1c4", "name": "9a2d242b-b087-4c69-8f6d-278d9910f3d0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3058115791316, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6614039959360709, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3da29d94-7b41-43c1-93a6-dfa9f53858d7", "name": "9aa3ae61-c7b5-47b7-aa9d-5c8c80616f35", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "263e7d44-927e-42de-9b33-bc043e89c1c4"}}}]}, {"uuid": "513733d5-ddd6-4f64-84e2-3b9839127ace", "name": "load_p1rlv13606_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29838633-5c95-4b73-8227-cfa7f4aedc32"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3da29d94-7b41-43c1-93a6-dfa9f53858d7"}}}}, {"uuid": "c3508a5a-022c-43f9-9b4e-2ae2096aaa94", "name": "2aab3bd4-5cf8-4bcd-8736-1ba0c8b52714_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3058115791316, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6614039959360709, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "db7406f9-285f-4b88-a7df-591a5a6e057e", "name": "7e72a4ff-304d-46fd-b528-4db1ec619d00", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c3508a5a-022c-43f9-9b4e-2ae2096aaa94"}}}]}, {"uuid": "c3367ac3-ed0f-4f82-9322-d35372941dad", "name": "load_p1rlv13606_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29838633-5c95-4b73-8227-cfa7f4aedc32"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "db7406f9-285f-4b88-a7df-591a5a6e057e"}}}}, {"uuid": "d7118512-4d9f-4803-a23a-381c995f83d5", "name": "8f5f7a71-ef92-4554-b3f5-ec6859e30f41_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a684586-7b36-4a30-97ad-40077a5b1a2a", "name": "8bd626f0-1c1f-4b3d-97d1-a826eba24e2a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d7118512-4d9f-4803-a23a-381c995f83d5"}}}]}, {"uuid": "e224fb14-299d-47f6-9ef1-eda559eb944e", "name": "load_p1rlv13608_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5e8caf4-4d81-4bbd-98df-6622c5ad0563"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a684586-7b36-4a30-97ad-40077a5b1a2a"}}}}, {"uuid": "28630b53-5791-4151-9f80-b012654e5bbe", "name": "22d967d4-e19a-4c1e-8516-2630a06cb526_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "17a1254d-30de-4ff2-9c67-8f9c56bcdcdb", "name": "b8b4fca4-7ce8-4b31-8cea-14e2ee0c4126", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "28630b53-5791-4151-9f80-b012654e5bbe"}}}]}, {"uuid": "9e615355-12ee-4e44-8d83-55496ef1fcf3", "name": "load_p1rlv13608_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5e8caf4-4d81-4bbd-98df-6622c5ad0563"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "17a1254d-30de-4ff2-9c67-8f9c56bcdcdb"}}}}, {"uuid": "1feccc53-8a55-4dc6-9f14-4cf6e7aeebdc", "name": "8e9ec97c-4e8e-477f-ae8c-95e2d6519669_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5204227867871802, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7134940441409878, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "efc5b363-454a-4a41-938c-d9814f2c1f71", "name": "56b8d8b3-7160-498a-adf8-e9d5489fc83e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1feccc53-8a55-4dc6-9f14-4cf6e7aeebdc"}}}]}, {"uuid": "db709395-c523-49cd-bc4c-951458b96c38", "name": "load_p1rlv13610_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17d92377-b4f1-4194-89cd-130bddb9b77c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "efc5b363-454a-4a41-938c-d9814f2c1f71"}}}}, {"uuid": "3d4a40ad-cf2f-48cc-91b8-c510fcfd720a", "name": "2f6e39fc-02dc-4ced-b0c9-d2e034212c8b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5204227867871802, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7134940441409878, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "22cf121f-0a5e-4231-a163-421c123a468b", "name": "ac3812fd-6712-48ea-a30a-3a72ae609341", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3d4a40ad-cf2f-48cc-91b8-c510fcfd720a"}}}]}, {"uuid": "30ca95f8-c26e-4560-b35e-048e5962d8eb", "name": "load_p1rlv13610_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17d92377-b4f1-4194-89cd-130bddb9b77c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "22cf121f-0a5e-4231-a163-421c123a468b"}}}}, {"uuid": "a9e4bce4-e5ea-4dbe-9c8b-0996a5871289", "name": "b0ee7b25-6a5f-4828-bb53-791e41cee671_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2489699911360574, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6200743429841856, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ace91704-0ee2-4020-8008-431ae1f26054", "name": "eebf7c81-db20-425a-8370-c45b1c52bb94", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a9e4bce4-e5ea-4dbe-9c8b-0996a5871289"}}}]}, {"uuid": "2f7690c2-b063-4a26-95de-fd6e37f8f5e8", "name": "load_p1rlv13611_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "630b2a63-622f-4f78-8390-77c69ba7e393"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ace91704-0ee2-4020-8008-431ae1f26054"}}}}, {"uuid": "38d953b6-3f7b-4e8e-be9a-ae293ecbf7d8", "name": "42816fc3-6691-4291-a26a-fc09ab7e3bc0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2489699911360574, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6200743429841856, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5dd03872-be94-4cdd-a533-e296b0ac4845", "name": "594456f4-453a-4fc6-af35-02d1f8ae5882", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "38d953b6-3f7b-4e8e-be9a-ae293ecbf7d8"}}}]}, {"uuid": "911a5c75-08be-456c-973b-9a4c69d19096", "name": "load_p1rlv13611_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "630b2a63-622f-4f78-8390-77c69ba7e393"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5dd03872-be94-4cdd-a533-e296b0ac4845"}}}}, {"uuid": "ceabb95c-76b6-47da-a2a5-4e08546fcc2b", "name": "025048b4-8552-4dc2-9bb0-12431180acd8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0788570276665777, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5949433355568994, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e582b791-1f79-4fe0-9652-895edb6344c8", "name": "d53d11c2-17ce-4f3c-a9fd-6078dad4bbd9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ceabb95c-76b6-47da-a2a5-4e08546fcc2b"}}}]}, {"uuid": "61c13545-2cec-4589-b92e-12a351832386", "name": "load_p1rlv13612_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6eda3e97-a618-41ab-ae55-ba67f6bb0234"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e582b791-1f79-4fe0-9652-895edb6344c8"}}}}, {"uuid": "38891ee9-4cab-4112-95d0-c271e8712dac", "name": "2a6196bf-11e5-4c12-ae76-cd971eb48e56_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0788570276665777, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5949433355568994, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2c0dfc31-f7c5-448a-b043-29789cc89020", "name": "7df2e922-0b73-4fa6-9815-4813fb83d211", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "38891ee9-4cab-4112-95d0-c271e8712dac"}}}]}, {"uuid": "950cc650-04a5-4d24-bcbe-53ff2c5a8a71", "name": "load_p1rlv13612_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6eda3e97-a618-41ab-ae55-ba67f6bb0234"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2c0dfc31-f7c5-448a-b043-29789cc89020"}}}}, {"uuid": "615db8c4-a370-422f-8b4d-781af51be9d4", "name": "ef027f39-0c3c-4bc3-8c3f-55acd3dc42f9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4038244377730775, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.30842299757959857, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "577b1b4d-48de-488a-b861-edbf0baf30ba", "name": "05b1a662-a415-49ce-a317-1d02d95e6738", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "615db8c4-a370-422f-8b4d-781af51be9d4"}}}]}, {"uuid": "dd4d943d-5659-4a56-b23f-4c946dda2361", "name": "load_p1rlv13613_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "216537dd-ea7b-461c-b821-99491c41b7f0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "577b1b4d-48de-488a-b861-edbf0baf30ba"}}}}, {"uuid": "5dc94bd8-c89f-4a2d-89cb-5ec7d3fd4fd5", "name": "a779b030-b0ef-4643-9c38-2a0b46685b34_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4038244377730775, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.30842299757959857, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "099b682b-fba1-4215-bfcf-8fc8cec8d482", "name": "858472de-7dc6-4d68-b184-da80b2f6fe29", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5dc94bd8-c89f-4a2d-89cb-5ec7d3fd4fd5"}}}]}, {"uuid": "3c640205-45c4-40ae-9e42-96ac27b81452", "name": "load_p1rlv13613_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "216537dd-ea7b-461c-b821-99491c41b7f0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "099b682b-fba1-4215-bfcf-8fc8cec8d482"}}}}, {"uuid": "c401073b-65fd-4fcc-a753-63093a15d2a7", "name": "aa64dd19-278b-4f71-b580-5e4a6d3dd375_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8b433e2b-9be7-4845-9f80-726834f5e0a3", "name": "80429f8b-4518-49fa-821e-18823aba8c08", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c401073b-65fd-4fcc-a753-63093a15d2a7"}}}]}, {"uuid": "513e3258-3983-4da3-bcc3-6daa810f2225", "name": "load_p1rlv13614_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3de8b994-01ba-4eae-b9cf-7fb174d32355"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8b433e2b-9be7-4845-9f80-726834f5e0a3"}}}}, {"uuid": "c8bf0b27-96cd-421f-8407-d565d173abd1", "name": "da73a03b-3f48-4f38-9384-ac4f10889abd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "650cf6ba-fe0c-4878-b263-0128aa0144d0", "name": "5a5810e9-1f98-404f-a07c-e1219374cffa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c8bf0b27-96cd-421f-8407-d565d173abd1"}}}]}, {"uuid": "7406de4a-2f49-4d2a-8c76-cafbe9ba85c2", "name": "load_p1rlv13614_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3de8b994-01ba-4eae-b9cf-7fb174d32355"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "650cf6ba-fe0c-4878-b263-0128aa0144d0"}}}}, {"uuid": "c661fa66-2f5a-43d5-99bf-3ff16796aaed", "name": "c0e4c6b3-3279-479f-ac5d-8dc382c17966_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5937162117629007, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7166618655640316, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7153f498-dbb9-489e-b8e7-8f16d884d4c2", "name": "e9e9f350-68d2-45c2-ba4d-47d5bba6f8e0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c661fa66-2f5a-43d5-99bf-3ff16796aaed"}}}]}, {"uuid": "f9a7de0e-1624-4e03-a4d4-0bf885f4db72", "name": "load_p1rlv13616_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "850d5b69-14cf-4a18-8cb0-4f1b3033b0aa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7153f498-dbb9-489e-b8e7-8f16d884d4c2"}}}}, {"uuid": "84568431-202f-46d3-a1a7-6cf36056966d", "name": "4c3f9928-dd45-4c08-8226-a9af82946f53_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5937162117629007, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7166618655640316, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4ff9e464-1d53-4124-aa0c-1d94088c75da", "name": "f60b7063-cd28-448b-8075-e90671f50e66", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "84568431-202f-46d3-a1a7-6cf36056966d"}}}]}, {"uuid": "63f4474e-0953-4d5e-b2d1-64cf24a77cc6", "name": "load_p1rlv13616_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "850d5b69-14cf-4a18-8cb0-4f1b3033b0aa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4ff9e464-1d53-4124-aa0c-1d94088c75da"}}}}, {"uuid": "0243729f-a4f3-4b56-a9ab-92767d1d70a5", "name": "6358a027-9c78-4156-8d36-a3bb6ae9dea7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.32403643380503, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6293121819683343, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ec564e10-1096-40d1-aabf-086dcfce9ad1", "name": "bfbd1fab-efe8-4742-9ec7-e067bf5b8101", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0243729f-a4f3-4b56-a9ab-92767d1d70a5"}}}]}, {"uuid": "9d936c16-a4ef-41d3-a02b-81a91da4ab6f", "name": "load_p1rlv13618_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f823a90c-effd-489c-9e0a-c110ccb7b9e8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ec564e10-1096-40d1-aabf-086dcfce9ad1"}}}}, {"uuid": "982da60c-87b4-4c34-ab26-f5fc1800475c", "name": "7d175011-18a2-48ee-9860-86faf3a84ead_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.32403643380503, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6293121819683343, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a60f819f-3886-44bb-b377-d01b1a10dbb7", "name": "b5976cb3-6e35-4410-b95d-deb0d34c43e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "982da60c-87b4-4c34-ab26-f5fc1800475c"}}}]}, {"uuid": "ecfe68a2-0142-4266-a254-a2845e55b700", "name": "load_p1rlv13618_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f823a90c-effd-489c-9e0a-c110ccb7b9e8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a60f819f-3886-44bb-b377-d01b1a10dbb7"}}}}, {"uuid": "1a69abb9-b58e-4d90-82f6-eb37166b9bd1", "name": "8fb1d5ac-e728-4989-a7bc-cee6ea816c78_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f3a8970e-e470-4043-80aa-fb20167e1294", "name": "5abaf938-70c7-4202-81f3-18640982dbd3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1a69abb9-b58e-4d90-82f6-eb37166b9bd1"}}}]}, {"uuid": "81bfac05-e086-4de0-83c9-c6e2a05cc9a7", "name": "load_p1rlv13619_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f693a1d2-5499-4810-9458-f205eda265fa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f3a8970e-e470-4043-80aa-fb20167e1294"}}}}, {"uuid": "26cc3290-18c5-492c-a8b9-e11d1ac7ae2b", "name": "d10fdde6-9faf-436f-8462-ad79941e50fd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50973f29-fe75-4d0e-9ddb-b975772b2ce8", "name": "afdb77a0-c05b-4936-8e17-42daaec74c50", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "26cc3290-18c5-492c-a8b9-e11d1ac7ae2b"}}}]}, {"uuid": "9e9747fe-1fab-4906-80cc-2990dc64a58d", "name": "load_p1rlv13619_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f693a1d2-5499-4810-9458-f205eda265fa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50973f29-fe75-4d0e-9ddb-b975772b2ce8"}}}}, {"uuid": "540b6425-7b6a-418a-9407-b741ccfbc1f0", "name": "331275d4-11df-4025-bd14-639b10811382_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3711169311548215, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.698133467399761, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dd8c0a0d-94a1-4a22-8ae4-7f99f1e72767", "name": "cba0580c-e34b-4136-934a-1954c8bef28e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "540b6425-7b6a-418a-9407-b741ccfbc1f0"}}}]}, {"uuid": "cd00aa99-b5c4-414d-8e55-6ec7ae7ed2cf", "name": "load_p1rlv13622_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4540b2cb-ee21-4515-a7ca-fbca371f060d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dd8c0a0d-94a1-4a22-8ae4-7f99f1e72767"}}}}, {"uuid": "b69fd5c7-dfe1-4a99-bafc-eeaa6547cdde", "name": "b932ded9-91ac-49b2-9cf7-60be0a24b0de_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3711169311548215, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.698133467399761, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b511ff2f-d16a-4da3-8c26-026b36bcf320", "name": "81520e07-1b5e-47f8-831d-fbc974227fc0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b69fd5c7-dfe1-4a99-bafc-eeaa6547cdde"}}}]}, {"uuid": "be39051c-160a-4255-82db-c4f94178fc78", "name": "load_p1rlv13622_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4540b2cb-ee21-4515-a7ca-fbca371f060d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b511ff2f-d16a-4da3-8c26-026b36bcf320"}}}}, {"uuid": "16db1fde-6327-40dc-b52c-9f4a9422dcab", "name": "b644319d-53f3-449a-8718-b090f40475ed_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6a2b4aa1-0e89-41f0-b2ee-237b8b4595cb", "name": "3194b37e-7435-4ed6-af61-d734630c7a8b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "16db1fde-6327-40dc-b52c-9f4a9422dcab"}}}]}, {"uuid": "823d3c38-d418-44a7-b3e7-990cef254e23", "name": "load_p1rlv13623_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80f60ab3-722f-4765-8b91-4fd0196171d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6a2b4aa1-0e89-41f0-b2ee-237b8b4595cb"}}}}, {"uuid": "6abe6328-7df4-44da-be3e-ba9d24e13cf2", "name": "5663592a-6245-44f0-8eec-b827b8056d8e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "386b9a03-f06a-44a2-8c0a-a07514b3e02c", "name": "efd73571-4bdf-4f76-8caa-8ca5bc2e86ce", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6abe6328-7df4-44da-be3e-ba9d24e13cf2"}}}]}, {"uuid": "a548b0cf-d329-424c-9939-c106e24fd913", "name": "load_p1rlv13623_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80f60ab3-722f-4765-8b91-4fd0196171d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "386b9a03-f06a-44a2-8c0a-a07514b3e02c"}}}}, {"uuid": "6353637a-3b3c-4a60-98ca-da3849ffab62", "name": "83606068-7e13-44f5-bd59-8eb99d849b7e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.611133182200907, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.07668264048246332, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5e111da4-7213-4700-aef8-69237ad31af7", "name": "55b70704-76f8-4604-abe8-e6358eb78676", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6353637a-3b3c-4a60-98ca-da3849ffab62"}}}]}, {"uuid": "87bf233e-57f9-4173-b00a-ad70cdf98074", "name": "load_p1rlv13624_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a5746d1-24a6-4ae4-b5dc-cef23b56660d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5e111da4-7213-4700-aef8-69237ad31af7"}}}}, {"uuid": "e7d644a0-c392-4633-988e-6be09deff0c3", "name": "035df44e-9561-422c-998f-a75dbe9ae4d4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.611133182200907, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.07668264048246332, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dd42cc15-e607-43c0-abb3-28e853c03221", "name": "fd2bc551-42c3-4ced-98c1-ba15d124bc6f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e7d644a0-c392-4633-988e-6be09deff0c3"}}}]}, {"uuid": "32fa6b51-eaaf-436a-bf91-636c328ee365", "name": "load_p1rlv13624_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a5746d1-24a6-4ae4-b5dc-cef23b56660d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dd42cc15-e607-43c0-abb3-28e853c03221"}}}}, {"uuid": "de0e49fe-3bdc-4a7d-b7d7-8338ab3dd376", "name": "777e7565-5332-4b34-962b-6a3114ca9330_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "900c9dcb-6b50-42ef-b05e-f4269e808dc3", "name": "ff4eb721-cb89-4c0e-8201-228b68fcbabe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "de0e49fe-3bdc-4a7d-b7d7-8338ab3dd376"}}}]}, {"uuid": "2706875b-9294-4ba4-bf0e-031c0118dbcc", "name": "load_p1rlv13625_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c667408-52a0-4258-8e93-557c94520a1e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "900c9dcb-6b50-42ef-b05e-f4269e808dc3"}}}}, {"uuid": "3ca686af-a312-424b-ad0a-a2857bea5608", "name": "da0f3f06-1012-4b11-b775-12810257b6b1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dbf022ae-cc92-42fb-80a6-57b5f4af35c9", "name": "e78818ab-c2d2-45d7-8e49-4178d541aa87", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3ca686af-a312-424b-ad0a-a2857bea5608"}}}]}, {"uuid": "3f8f8afb-ed05-41b4-b003-9dbd2533152e", "name": "load_p1rlv13625_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c667408-52a0-4258-8e93-557c94520a1e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dbf022ae-cc92-42fb-80a6-57b5f4af35c9"}}}}, {"uuid": "b5b8ebb5-3bad-4a3e-9274-6b3fe9628924", "name": "0d3c68fa-98b9-4457-9623-b2ddbef6bad9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2167250892906645, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5534364726692191, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "495030ab-3b27-4d33-b025-282b4b044338", "name": "2b498706-f03c-4f51-be0e-276bb22b8961", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5b8ebb5-3bad-4a3e-9274-6b3fe9628924"}}}]}, {"uuid": "56acabce-8878-49c1-b94c-af9220f4e454", "name": "load_p1rlv13626_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aeea20e0-9908-4f28-aa5d-068244e3861b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "495030ab-3b27-4d33-b025-282b4b044338"}}}}, {"uuid": "60e32a94-a8bc-42dd-8a92-eba24c87b680", "name": "b56423f4-655b-404a-9ed5-c661669886fd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2167250892906645, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5534364726692191, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1d65980a-33fe-4dfd-9088-9855d7e3a557", "name": "6243df8a-9e5d-47cb-b112-436fe69e32bd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "60e32a94-a8bc-42dd-8a92-eba24c87b680"}}}]}, {"uuid": "94ea13bc-304f-49d4-84d0-97ddf66b1fba", "name": "load_p1rlv13626_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aeea20e0-9908-4f28-aa5d-068244e3861b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1d65980a-33fe-4dfd-9088-9855d7e3a557"}}}}, {"uuid": "2ebe26fa-10b8-4996-a592-cf2d510877fc", "name": "fd6b2f83-f55c-4178-84d4-25f825f42afc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "29d57d91-dfb5-45cd-8116-2ed75b39201d", "name": "b9a16346-3061-4545-8663-f33e340b22b3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2ebe26fa-10b8-4996-a592-cf2d510877fc"}}}]}, {"uuid": "a9f67b6f-8541-4045-be0d-ac8ec292b43e", "name": "load_p1rlv13627_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bd69c55-2141-4c8e-becf-efa4bff8a63e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "29d57d91-dfb5-45cd-8116-2ed75b39201d"}}}}, {"uuid": "d390e1cb-6ad3-4c4e-8727-81af1319dbf9", "name": "e001b741-a080-4706-be40-76b9d706fd05_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aaccb708-0a7f-4541-9e29-2794fd6b3222", "name": "689efcce-d483-476d-8917-ae96f946d395", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d390e1cb-6ad3-4c4e-8727-81af1319dbf9"}}}]}, {"uuid": "1fe6206e-10f8-4593-a6d9-66b3a1e11005", "name": "load_p1rlv13627_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bd69c55-2141-4c8e-becf-efa4bff8a63e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aaccb708-0a7f-4541-9e29-2794fd6b3222"}}}}, {"uuid": "5502d664-87dc-4e88-928a-98ea7b6e2f1c", "name": "c876f41e-35b4-4931-9d0b-d9c056f9e7cf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6027984746974515, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12293402966163972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "83b5da43-aa46-4ca2-b714-e3e8d4d9aaa9", "name": "2d19e5a5-a6ec-41e1-82d1-d8affbe0489e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5502d664-87dc-4e88-928a-98ea7b6e2f1c"}}}]}, {"uuid": "f69095ba-372d-4810-8411-694971f43d18", "name": "load_p1rlv13628_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e47df44a-79f1-423b-a295-c9c354795895"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "83b5da43-aa46-4ca2-b714-e3e8d4d9aaa9"}}}}, {"uuid": "03010734-757c-40c6-8d5b-a9ba3e866412", "name": "c2fbd6ce-63a8-45aa-9508-6fc3cd17844f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6027984746974515, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12293402966163972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "28f34706-c5c5-47c0-8346-6aa590cb993d", "name": "f1053a09-9888-4e41-9153-fdb1d0b05c4b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "03010734-757c-40c6-8d5b-a9ba3e866412"}}}]}, {"uuid": "79aedce6-a8bc-4f93-b31b-189b72b22de8", "name": "load_p1rlv13628_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e47df44a-79f1-423b-a295-c9c354795895"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "28f34706-c5c5-47c0-8346-6aa590cb993d"}}}}, {"uuid": "00ece0df-1a03-4625-9c72-a0ca6a712f83", "name": "4e76d46b-b0e8-436f-9961-83e68ced5a03_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b240055e-61a7-4a40-8728-b15c9c4e3528", "name": "6954db8d-9915-4086-89b0-dd442cd5b3cb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "00ece0df-1a03-4625-9c72-a0ca6a712f83"}}}]}, {"uuid": "56bffc71-20a4-4d90-8fff-3853b9736046", "name": "load_p1rlv13629_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b4358536-b06f-486d-b336-3a8576b428d0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b240055e-61a7-4a40-8728-b15c9c4e3528"}}}}, {"uuid": "b5346d4f-4346-47c1-ad51-489a5fc3e057", "name": "ee48d810-87be-476c-b6e6-fde84b05eff7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4a16f94c-68e7-4d9b-a619-fb3c0c6948e1", "name": "a7574a04-fc39-4357-9ec9-540175bf69c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5346d4f-4346-47c1-ad51-489a5fc3e057"}}}]}, {"uuid": "d512e023-534b-4887-8712-d2b367fd903e", "name": "load_p1rlv13629_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b4358536-b06f-486d-b336-3a8576b428d0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4a16f94c-68e7-4d9b-a619-fb3c0c6948e1"}}}}, {"uuid": "db5ab1aa-2d9c-4125-94ab-3823975c45a3", "name": "44d7417b-8f31-4b33-a119-6accec609369_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.501244965400895, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7307193315393806, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d7b6bd43-b473-493b-bf4f-e32b4826ed05", "name": "cee0d6e8-87e3-4fd9-b102-fbbf8d850eb5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "db5ab1aa-2d9c-4125-94ab-3823975c45a3"}}}]}, {"uuid": "2af4f9b5-566b-464a-89b4-4f17c9947451", "name": "load_p1rlv13630_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f474e4ba-6300-4014-afe9-c245e08cf3c5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d7b6bd43-b473-493b-bf4f-e32b4826ed05"}}}}, {"uuid": "699807f1-fae9-44bc-88b0-f349cb4bed56", "name": "221e650d-7f9e-4569-b6d8-d9725b7f3b9d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.501244965400895, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7307193315393806, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "19f39d00-78bc-4894-a883-664fbe549f75", "name": "1bbe9954-28bc-42a3-9d62-ef25f2d9ce00", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "699807f1-fae9-44bc-88b0-f349cb4bed56"}}}]}, {"uuid": "e8373eda-07bd-4a9d-acc2-aa85eef3e840", "name": "load_p1rlv13630_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f474e4ba-6300-4014-afe9-c245e08cf3c5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "19f39d00-78bc-4894-a883-664fbe549f75"}}}}, {"uuid": "e3c35c21-d745-4909-889f-6bff9dea666a", "name": "8996a840-c56b-4244-a5bd-a936ab7e4f43_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7837050665512109, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.44874911637056014, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5ca7329c-2183-473b-95a9-77f2be94a3ca", "name": "0944f457-4c1a-46bc-b7c0-8ca6b1c791ce", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e3c35c21-d745-4909-889f-6bff9dea666a"}}}]}, {"uuid": "0a898f62-ea5c-418a-acc7-02c3c134dc37", "name": "load_p1rlv13631_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6015a810-79da-480f-b1a1-fd6a4abdba37"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5ca7329c-2183-473b-95a9-77f2be94a3ca"}}}}, {"uuid": "68c8d2e9-bf41-4d52-b183-24dae14b5724", "name": "248fdd00-1485-49b2-9fa5-142adc189657_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7837050665512109, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.44874911637056014, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b92698dc-2935-4f96-a813-b16d1e060ed2", "name": "1c437de2-b58b-4c30-af12-93c0d6925bcd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "68c8d2e9-bf41-4d52-b183-24dae14b5724"}}}]}, {"uuid": "91760696-f2be-4ed0-8a50-98d918418a84", "name": "load_p1rlv13631_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6015a810-79da-480f-b1a1-fd6a4abdba37"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b92698dc-2935-4f96-a813-b16d1e060ed2"}}}}, {"uuid": "625c002a-2b35-4e06-b117-f555d3def42e", "name": "05f7d4e7-22f5-4b84-ab66-ce7cc8d7b3fd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.008167500419157, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.871384812064858, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aae35308-2937-4f39-993b-ca2d5432f45b", "name": "0a7ea9ae-5600-43f7-aa3d-735141c55119", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "625c002a-2b35-4e06-b117-f555d3def42e"}}}]}, {"uuid": "d4468576-026b-47a1-ae83-e2a50b6701c7", "name": "load_p1rlv13632_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b712121-d0c2-488a-9224-bea72928796f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aae35308-2937-4f39-993b-ca2d5432f45b"}}}}, {"uuid": "85454153-f482-43f0-9863-54d33d19ad67", "name": "806f51fe-a83c-42ca-9771-481c667cb9fd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.008167500419157, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.871384812064858, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c5fb0cff-fe68-4ed9-b59f-4c1190ab0bf5", "name": "c5b13880-b54d-4f04-99cb-1632c874ae4a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "85454153-f482-43f0-9863-54d33d19ad67"}}}]}, {"uuid": "d2cb09f8-4845-4eb7-952d-96a7ea7bd35b", "name": "load_p1rlv13632_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b712121-d0c2-488a-9224-bea72928796f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c5fb0cff-fe68-4ed9-b59f-4c1190ab0bf5"}}}}, {"uuid": "4c650d9a-e789-4024-b747-a4f9b23a6fcb", "name": "c444ea98-6fdd-40da-bcdb-076334c4a3c8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4201171911594663, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7913664471178815, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7ddcbf16-7aee-400a-867b-1625d9b2aae7", "name": "e682a673-e790-4b62-937b-bbd1709020ea", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4c650d9a-e789-4024-b747-a4f9b23a6fcb"}}}]}, {"uuid": "a24f56d6-69d9-4acf-adf0-a7c175597c41", "name": "load_p1rlv13633_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b3fe33f-fdcf-42f5-be08-8da15a4d4958"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7ddcbf16-7aee-400a-867b-1625d9b2aae7"}}}}, {"uuid": "97c7df5d-7d20-4f19-a8df-ff4d27029248", "name": "919b3572-0eda-41a4-a30b-d2ebdca56740_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4201171911594663, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7913664471178815, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7d65b2fe-e861-403c-aacd-ff1a8c6f452e", "name": "2528e6e0-563d-4ad3-aef0-30576fc5cb62", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "97c7df5d-7d20-4f19-a8df-ff4d27029248"}}}]}, {"uuid": "c293303e-86dc-4b84-8db2-eedc97de8c50", "name": "load_p1rlv13633_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b3fe33f-fdcf-42f5-be08-8da15a4d4958"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7d65b2fe-e861-403c-aacd-ff1a8c6f452e"}}}}, {"uuid": "09ccac70-d664-460f-b367-a6828d226496", "name": "67a46fb3-067e-4411-9ca2-215ad98086df_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0491915565570302, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1506537762556939, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a9167dd0-eec4-4187-8d69-1b16829d38bb", "name": "0bcb7770-1b34-4ff2-a46b-7ab95042a64a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "09ccac70-d664-460f-b367-a6828d226496"}}}]}, {"uuid": "4174bb0a-452a-46f0-b4e9-42e67e6fb9f1", "name": "load_p1rlv13634_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "987b05d5-9bb9-434d-98b3-623ee5014870"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a9167dd0-eec4-4187-8d69-1b16829d38bb"}}}}, {"uuid": "a60ff0c5-8c9e-4430-bbe3-e61a9c4b32a2", "name": "a3ef54f3-b048-4cf2-b05c-35382e96d908_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0491915565570302, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1506537762556939, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bd28c65e-c687-47b6-afd7-6bd5a68ec166", "name": "461fcc9c-2fd7-4eab-9c4d-c95afcb50ac7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a60ff0c5-8c9e-4430-bbe3-e61a9c4b32a2"}}}]}, {"uuid": "fda346e7-2464-4bd6-8a0c-8e34f4705a79", "name": "load_p1rlv13634_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "987b05d5-9bb9-434d-98b3-623ee5014870"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bd28c65e-c687-47b6-afd7-6bd5a68ec166"}}}}, {"uuid": "03501c13-ff46-45d2-862c-55d026d69060", "name": "fa7fa910-1b72-44d2-88c9-2c5d4f2160ff_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.31125911334339, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6469035988597648, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "99b34702-aefb-4ecf-9662-efca449d746a", "name": "61b45131-846f-46d6-9521-ecd7655136f7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "03501c13-ff46-45d2-862c-55d026d69060"}}}]}, {"uuid": "2a209559-4d1c-4f42-9a45-244995b2999e", "name": "load_p1rlv13635_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc33013a-6a90-46a7-9127-f32288111c14"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "99b34702-aefb-4ecf-9662-efca449d746a"}}}}, {"uuid": "44aa3bec-ea60-44c4-844a-2e34f39d5b9d", "name": "d29dc4e2-aa32-48e4-831a-60e96c6c3418_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.31125911334339, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6469035988597648, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e2c7b5ec-90a9-45c2-bebe-68f2d9cf2fdf", "name": "ceecdb9d-06d8-43cb-8edc-f252113ff87f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "44aa3bec-ea60-44c4-844a-2e34f39d5b9d"}}}]}, {"uuid": "a846042f-a399-4b23-88b5-28a16125f77f", "name": "load_p1rlv13635_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc33013a-6a90-46a7-9127-f32288111c14"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e2c7b5ec-90a9-45c2-bebe-68f2d9cf2fdf"}}}}, {"uuid": "71f32ea8-d8a0-4783-b914-d623b778fdc7", "name": "e316d186-53a6-4f1c-9669-1116390b9f54_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d1ea5d58-0f18-4498-82c6-9d28a73a51a3", "name": "8ae641c4-13c7-49ad-937c-d462cbf99050", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "71f32ea8-d8a0-4783-b914-d623b778fdc7"}}}]}, {"uuid": "dde7312b-6aa6-4692-91ae-bd663ed25cb0", "name": "load_p1rlv13636_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4d3fe62-b327-4fc6-b2aa-795c9475019a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d1ea5d58-0f18-4498-82c6-9d28a73a51a3"}}}}, {"uuid": "50ebb994-5b3b-45b1-81a3-9101ce95a4ed", "name": "896c2f10-b80d-4849-bac7-9f63bbed8a43_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e70432b1-a134-47c3-b5c5-f7b43d821f3f", "name": "a3f8379e-dbf1-4014-ac38-e848ac421bca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "50ebb994-5b3b-45b1-81a3-9101ce95a4ed"}}}]}, {"uuid": "51241fc7-c76e-4bf9-a2ef-90652f4efae3", "name": "load_p1rlv13636_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4d3fe62-b327-4fc6-b2aa-795c9475019a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e70432b1-a134-47c3-b5c5-f7b43d821f3f"}}}}, {"uuid": "4c46cf04-de7e-4d34-bbfc-5cb180717b6e", "name": "16d6aa2b-a551-495d-af08-1e3622784797_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.942829069048031, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.025560880160820944, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "24d7765a-f07e-4e6b-8a5a-4df51bbf830a", "name": "2e3b5926-fa3e-41d3-bc84-1ba6532ae963", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4c46cf04-de7e-4d34-bbfc-5cb180717b6e"}}}]}, {"uuid": "3e2bd199-1a25-451c-a362-e3b28bbac774", "name": "load_p1rlv13637_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30c470ac-39d1-4379-9ae7-790d912bce2c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "24d7765a-f07e-4e6b-8a5a-4df51bbf830a"}}}}, {"uuid": "6a526513-421e-4dbf-9980-3c77433e854d", "name": "ed201a0a-e610-42cf-a003-a35c43a1cb2b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.942829069048031, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.025560880160820944, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b9cd2d9b-dd5e-4ea7-b10e-746c7a702745", "name": "69434e8b-8305-48f1-a6cb-4c5294aaae7f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6a526513-421e-4dbf-9980-3c77433e854d"}}}]}, {"uuid": "a00fc30c-06aa-41c0-a402-c6f017e5d5fc", "name": "load_p1rlv13637_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30c470ac-39d1-4379-9ae7-790d912bce2c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b9cd2d9b-dd5e-4ea7-b10e-746c7a702745"}}}}, {"uuid": "ad6f4b40-f5a4-47a2-964b-8ce502f3d7dc", "name": "11087ee2-87bd-4257-97dd-3f6eed4c5119_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9149869461814677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5767582022429075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "31e2e4b3-dc1e-466a-8d38-c2eac6c6dd63", "name": "9fcf32bf-adc6-4c44-b307-bd05599604cd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ad6f4b40-f5a4-47a2-964b-8ce502f3d7dc"}}}]}, {"uuid": "a15380e8-2648-4beb-8e30-e530c615396d", "name": "load_p1rlv13638_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db3908f7-94f5-43a7-a3de-1f6c9b72ebd4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "31e2e4b3-dc1e-466a-8d38-c2eac6c6dd63"}}}}, {"uuid": "c53ddde5-2039-402e-980c-16a0f3fdc516", "name": "f3182493-3ea8-4919-807c-2e5cf477f3b3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9149869461814677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5767582022429075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2d627562-5a99-4b97-810f-c0c324d6f7b2", "name": "4858ab75-c396-46a5-b5e9-eaf5f0a5acc5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c53ddde5-2039-402e-980c-16a0f3fdc516"}}}]}, {"uuid": "f767f99c-517e-4293-a22e-558482926470", "name": "load_p1rlv13638_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db3908f7-94f5-43a7-a3de-1f6c9b72ebd4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2d627562-5a99-4b97-810f-c0c324d6f7b2"}}}}, {"uuid": "2819f386-8f44-43b5-9d6c-678d19e3f8d7", "name": "3616b5fe-6980-4925-b3b2-eb27bbe1c497_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fd9ff23c-59b5-463a-b58b-27cdc50735ec", "name": "1c5e5eb7-33b3-4022-aaf7-45d672d8e2c0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2819f386-8f44-43b5-9d6c-678d19e3f8d7"}}}]}, {"uuid": "059d17b4-fe64-4805-bcd9-4e46f9e09235", "name": "load_p1rlv13639_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5484eab0-53a8-471c-92ec-29c11c08e740"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fd9ff23c-59b5-463a-b58b-27cdc50735ec"}}}}, {"uuid": "de1bfb30-3df8-4d09-8f71-222396ce7e69", "name": "0e34e63a-5733-4135-bba1-695543fae735_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f13d4010-6d55-4efe-8655-7521453e11e0", "name": "6210fd61-0848-43e8-9c2e-9c3bf700b9d0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "de1bfb30-3df8-4d09-8f71-222396ce7e69"}}}]}, {"uuid": "4f648b6f-b7e4-43fd-a91e-349c254189ca", "name": "load_p1rlv13639_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5484eab0-53a8-471c-92ec-29c11c08e740"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f13d4010-6d55-4efe-8655-7521453e11e0"}}}}, {"uuid": "ab18cebe-9955-405f-9911-fce8c9913a46", "name": "a471f35b-e72d-47c8-a43d-26e19b81faf7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "35d3008f-4e32-404e-a695-2aa7301c897b", "name": "2be52492-a9d7-4b9f-89e5-d7b666a6aff9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ab18cebe-9955-405f-9911-fce8c9913a46"}}}]}, {"uuid": "d9ba6877-fcb0-40d9-b3cc-e37733bf6458", "name": "load_p1rlv13640_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "653bdc0d-5b21-4640-861b-b88ddb5c651a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "35d3008f-4e32-404e-a695-2aa7301c897b"}}}}, {"uuid": "953924ef-3e84-4553-af18-876f4fe0fd5c", "name": "78c3d82f-a316-4d54-ab96-884224053acc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a3df4cb4-5997-4ca3-b6f5-33fe3f32a2bc", "name": "3b687e1f-5ad4-4334-8641-3a62e52c296d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "953924ef-3e84-4553-af18-876f4fe0fd5c"}}}]}, {"uuid": "98cf1c27-dbb5-4800-89c9-71335ef9faa2", "name": "load_p1rlv13640_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "653bdc0d-5b21-4640-861b-b88ddb5c651a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a3df4cb4-5997-4ca3-b6f5-33fe3f32a2bc"}}}}, {"uuid": "ff2bf355-ab80-4b01-998e-54880051bf9f", "name": "459eab03-c1ca-4265-8a6a-9806f03973e9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.725954562298933, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5866148963219024, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4adc22ee-af0f-46e4-b844-5de2777fadf9", "name": "f391628c-8d56-441e-bfda-3cc31ac49988", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ff2bf355-ab80-4b01-998e-54880051bf9f"}}}]}, {"uuid": "d30fa88e-eabd-48e1-b026-ecd2d7782dfc", "name": "load_p1rlv13641_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eb10938-4b73-406c-bed4-0bd01e0bc20d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4adc22ee-af0f-46e4-b844-5de2777fadf9"}}}}, {"uuid": "69cb7403-840f-440d-8a1a-b06c9aa92f0b", "name": "580fa1fd-d871-413b-a8f9-88bddf9d386a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.725954562298933, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5866148963219024, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82fc3122-1cc5-4744-9415-94b09dbd774f", "name": "8c1a17d5-8cde-4691-abb5-c4ad3ea0e1df", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "69cb7403-840f-440d-8a1a-b06c9aa92f0b"}}}]}, {"uuid": "ea414bd3-b37a-4371-a878-61328ce839fa", "name": "load_p1rlv13641_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eb10938-4b73-406c-bed4-0bd01e0bc20d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "82fc3122-1cc5-4744-9415-94b09dbd774f"}}}}, {"uuid": "d09f2a83-b5c9-4235-8679-a4570d4805f2", "name": "20d07da0-dae0-496c-9ca0-289a628db7bd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2219087879829873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3595087789107823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3831569f-5f73-48f2-a9ab-5a3616063410", "name": "3f700706-7d45-470d-8e42-ada404cb71e3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d09f2a83-b5c9-4235-8679-a4570d4805f2"}}}]}, {"uuid": "34ff9b20-48f4-434c-ad64-8773342da568", "name": "load_p1rlv13642_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "479d1486-ed05-44fa-8fab-64035623f267"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3831569f-5f73-48f2-a9ab-5a3616063410"}}}}, {"uuid": "ac8690af-35ef-4cf7-b728-5df66b0ec6ae", "name": "320e79cb-daa5-4360-97d5-7529918e9f19_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2219087879829873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3595087789107823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a4d6c511-9b88-47d5-9bf8-534ffb5d64a7", "name": "b03c670e-e129-426d-aa5d-d6c19f68019a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ac8690af-35ef-4cf7-b728-5df66b0ec6ae"}}}]}, {"uuid": "870c0741-671e-4fa5-8178-f061a1a30553", "name": "load_p1rlv13642_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "479d1486-ed05-44fa-8fab-64035623f267"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a4d6c511-9b88-47d5-9bf8-534ffb5d64a7"}}}}, {"uuid": "bd325d4d-1161-45e0-a72f-a63d6d594d11", "name": "0118f287-e659-44ea-b124-d4d4f7bd2f1f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0be1befb-4b3d-4ad7-a4af-35cac5f8452c", "name": "7f87bdbe-b5a6-4d42-b7eb-dac0ca68e3e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bd325d4d-1161-45e0-a72f-a63d6d594d11"}}}]}, {"uuid": "5ae8d23c-13f6-490b-bd31-a17c15dfad21", "name": "load_p1rlv13643_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20009de0-cbe7-4b4f-a046-425a6ae71925"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0be1befb-4b3d-4ad7-a4af-35cac5f8452c"}}}}, {"uuid": "c89ef2e0-f868-4dcd-bc19-b27e14951e25", "name": "f557316c-bda0-43e6-a08d-0bce1708c1af_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "393b1cad-6b55-4973-b28a-56692c2e4274", "name": "b9dca927-1456-4f14-a146-5f470c572560", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c89ef2e0-f868-4dcd-bc19-b27e14951e25"}}}]}, {"uuid": "0602d8b5-0a43-4a93-ba8a-e7eff78736a5", "name": "load_p1rlv13643_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20009de0-cbe7-4b4f-a046-425a6ae71925"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "393b1cad-6b55-4973-b28a-56692c2e4274"}}}}, {"uuid": "c1bbb515-b8c7-4c98-87e1-d29e17219acf", "name": "2489afdb-0ac5-4c87-b749-afc4d5c17807_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "45444b45-4777-4dcb-a5b6-a5318dd48642", "name": "95c301f7-5f36-46bb-a632-f91056dfd942", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c1bbb515-b8c7-4c98-87e1-d29e17219acf"}}}]}, {"uuid": "34afd116-cf35-4dee-8632-2c2db844aa7c", "name": "load_p1rlv13645_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1acad56e-b6d6-4fa7-a925-f242c1558eef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "45444b45-4777-4dcb-a5b6-a5318dd48642"}}}}, {"uuid": "729dec84-6190-48e8-8f28-1f1ac1ed1cae", "name": "5f2bf744-bd3e-4593-8c59-6ee59ce6ec97_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "545fd949-ca5f-4021-a9cb-70214da669b1", "name": "8e52d775-cd93-470f-a449-467dd1bd7da5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "729dec84-6190-48e8-8f28-1f1ac1ed1cae"}}}]}, {"uuid": "bab4d514-42f6-48f7-a8f0-3912a1e1a1c8", "name": "load_p1rlv13645_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1acad56e-b6d6-4fa7-a925-f242c1558eef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "545fd949-ca5f-4021-a9cb-70214da669b1"}}}}, {"uuid": "7de9fa63-d7d8-42be-8950-590bc369ae2a", "name": "1d3651b2-1ade-49fb-ab57-a9b07ad20ade_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4519136613739017, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7054970531635038, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c531f4fd-237f-4a4e-b8df-650e5c906732", "name": "956fe972-4e01-481c-84e7-1b6cbfeb7f20", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7de9fa63-d7d8-42be-8950-590bc369ae2a"}}}]}, {"uuid": "5599b81a-cb04-4ba8-95c5-f2ce0818c160", "name": "load_p1rlv13646_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fe0466e-cce5-4c6c-b13f-cedd349b6944"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c531f4fd-237f-4a4e-b8df-650e5c906732"}}}}, {"uuid": "d90b4bd1-901f-4ed8-b6c2-18f91fb1fbe0", "name": "288608e5-0375-438e-9815-90b527a03a3c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4519136613739017, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7054970531635038, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "615b821c-a77c-4577-9683-6b35a7e599b8", "name": "27907f11-b1a1-49ea-ac02-b474b0ee1296", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d90b4bd1-901f-4ed8-b6c2-18f91fb1fbe0"}}}]}, {"uuid": "49d1c147-c2e7-4c73-8f8c-c68335fae76f", "name": "load_p1rlv13646_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fe0466e-cce5-4c6c-b13f-cedd349b6944"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "615b821c-a77c-4577-9683-6b35a7e599b8"}}}}, {"uuid": "8ded91d9-819a-41a7-9317-5644c2b21466", "name": "ea7f762c-ce75-4d60-ace7-be83382b67ef_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7813411640480736, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4182052484168413, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "badfcc26-ec8f-4d69-827c-6970fb6fffba", "name": "2a06c444-3e0e-4bed-901f-2fcc499def0b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ded91d9-819a-41a7-9317-5644c2b21466"}}}]}, {"uuid": "a8732407-5084-4d7d-bc08-770676d828cd", "name": "load_p1rlv13647_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8753d37-07f1-45c6-a483-43cbfb6bf107"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "badfcc26-ec8f-4d69-827c-6970fb6fffba"}}}}, {"uuid": "b5e8a61b-47e3-4497-a372-da74225c037d", "name": "698ba49f-a12a-4a1c-a60e-3a4224a3fdf4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7813411640480736, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4182052484168413, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9905e932-f6db-4c5a-9953-3ae517967290", "name": "a8e4cb2a-552f-477b-990a-7d4864067f6b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5e8a61b-47e3-4497-a372-da74225c037d"}}}]}, {"uuid": "929e7d4b-7ca0-420b-a59f-8131acee3c6e", "name": "load_p1rlv13647_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8753d37-07f1-45c6-a483-43cbfb6bf107"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9905e932-f6db-4c5a-9953-3ae517967290"}}}}, {"uuid": "d9f54d7b-c79c-4e40-98df-ea703f5ac70d", "name": "e5c3a58c-b408-4539-89ca-bf1cf35ce61e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1343287185333217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10429894918818222, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "090bd7d6-3f1f-4e27-b141-78a2939dc01f", "name": "01cc5f96-812a-4b61-b1ee-ae944d1e9e2f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d9f54d7b-c79c-4e40-98df-ea703f5ac70d"}}}]}, {"uuid": "655fa1cb-f8f2-445b-8380-e4606ad75131", "name": "load_p1rlv13648_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62a29ac5-7227-43b2-b602-b1189cc93839"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "090bd7d6-3f1f-4e27-b141-78a2939dc01f"}}}}, {"uuid": "8a0039a2-6d46-4a15-89fd-0e48ddfa2026", "name": "13fc6f7a-f857-4fb9-9f1c-3fa2e404205f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1343287185333217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10429894918818222, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "edd294c3-09a4-4f8a-843d-59f0732f18cd", "name": "2de0392e-0063-46cd-873d-8218831e2e65", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a0039a2-6d46-4a15-89fd-0e48ddfa2026"}}}]}, {"uuid": "7f04e3b5-99a3-417b-9ea6-f2daab8d6fe8", "name": "load_p1rlv13648_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62a29ac5-7227-43b2-b602-b1189cc93839"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "edd294c3-09a4-4f8a-843d-59f0732f18cd"}}}}, {"uuid": "c0691bdd-89f2-488e-914c-503562a2c816", "name": "d5241df9-210a-4632-ba1f-31f5903cefa6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "905b259c-5f98-4478-a1d2-fcbedf1ada7e", "name": "03f14100-0af1-4c78-872a-9c54c3c9bdad", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c0691bdd-89f2-488e-914c-503562a2c816"}}}]}, {"uuid": "274e8dac-f955-4b5d-877d-34b969f045d4", "name": "load_p1rlv13649_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43867e2f-79ee-4cec-bed3-0cad0727118c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "905b259c-5f98-4478-a1d2-fcbedf1ada7e"}}}}, {"uuid": "adf27202-e69a-467a-9e93-2b422c27b8f5", "name": "b86a783e-92c5-4b8b-8f04-8de9193fa62b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b7b902de-dea3-4126-ab0b-8d5a36d63c29", "name": "03e22a3c-06dd-436a-a577-32b9e21ca18c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "adf27202-e69a-467a-9e93-2b422c27b8f5"}}}]}, {"uuid": "06d40c7c-d7d4-443a-b8aa-91d579b4708f", "name": "load_p1rlv13649_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43867e2f-79ee-4cec-bed3-0cad0727118c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b7b902de-dea3-4126-ab0b-8d5a36d63c29"}}}}, {"uuid": "d7d5af8b-daf2-4e4e-9b0d-ed795ed513cc", "name": "658f477d-eaba-4943-a7ee-2a81555af2a2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2570744264864886, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.02246974709606756, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bc03626c-630c-437c-81dd-3315b3978341", "name": "48a360e8-d80c-47b5-b6ba-5ff066efe523", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d7d5af8b-daf2-4e4e-9b0d-ed795ed513cc"}}}]}, {"uuid": "e539658e-9b51-4f32-8034-dfd8818aab1c", "name": "load_p1rlv13650_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fa2041e-34c4-4f1f-a329-74969c3da75f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bc03626c-630c-437c-81dd-3315b3978341"}}}}, {"uuid": "f6a3c7a8-3d24-4f7b-b91c-cb9c3f0b4f3f", "name": "e9d2125e-d841-4d9e-9531-0deabe5a9e78_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2570744264864886, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.02246974709606756, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d0336c96-d254-48cb-a8ab-5ca8ee4e509a", "name": "f759eb0e-e52e-4935-8183-af965777f183", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f6a3c7a8-3d24-4f7b-b91c-cb9c3f0b4f3f"}}}]}, {"uuid": "21214c31-8a2f-45c9-91dd-98abd124759a", "name": "load_p1rlv13650_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fa2041e-34c4-4f1f-a329-74969c3da75f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d0336c96-d254-48cb-a8ab-5ca8ee4e509a"}}}}, {"uuid": "dced574f-ef99-4a2b-ad7a-a26535c32b88", "name": "bed9e268-e4a4-4f24-85be-f266452ffd30_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d0c5d89c-bf53-4014-9e6c-fa9efe4580a4", "name": "4ef69988-cd3c-42a1-a5d2-6cddc8fe53ce", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dced574f-ef99-4a2b-ad7a-a26535c32b88"}}}]}, {"uuid": "4408d259-bb84-44ec-b02f-067428660b1d", "name": "load_p1rlv13651_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c808261e-a49e-4954-bdc4-a8b63d0ee25b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d0c5d89c-bf53-4014-9e6c-fa9efe4580a4"}}}}, {"uuid": "d1fc4eeb-9cc6-4172-b6d4-7289ca5ec624", "name": "a178b7f7-d214-4e92-b211-dec0140ceedb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4aa2831b-6bb2-4cc4-b21f-c46883712692", "name": "e7ae22a7-1090-4452-b54d-fd3f31d49079", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d1fc4eeb-9cc6-4172-b6d4-7289ca5ec624"}}}]}, {"uuid": "373dc048-2ea4-417c-8487-61c88a796053", "name": "load_p1rlv13651_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c808261e-a49e-4954-bdc4-a8b63d0ee25b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4aa2831b-6bb2-4cc4-b21f-c46883712692"}}}}, {"uuid": "69dfdb76-e6ee-4abd-9f38-d45756695404", "name": "36741a16-86b3-44a9-a284-dc5f6ede04b7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9eb220af-0b1b-474d-8a61-2dc6f753fbc0", "name": "ad9f0501-1f15-475c-ada7-35b8c17f18d2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "69dfdb76-e6ee-4abd-9f38-d45756695404"}}}]}, {"uuid": "e3181116-934c-4c25-bd6e-f1e06020124d", "name": "load_p1rlv13652_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3310c14a-d1ee-4d0c-8428-d002703c61d5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9eb220af-0b1b-474d-8a61-2dc6f753fbc0"}}}}, {"uuid": "b2c54594-b1f9-4654-a1b7-420fb0dc3ecf", "name": "62d8c279-f33b-48e5-a06f-2b23ab118224_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2f905575-f631-4ca9-b41d-5ee46496fbfb", "name": "a4c287e9-487e-469e-90ae-cc3f25dee8a0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b2c54594-b1f9-4654-a1b7-420fb0dc3ecf"}}}]}, {"uuid": "e4a891ed-1399-4dae-bb21-1c5fd0c3f2ff", "name": "load_p1rlv13652_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3310c14a-d1ee-4d0c-8428-d002703c61d5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2f905575-f631-4ca9-b41d-5ee46496fbfb"}}}}, {"uuid": "e8bc5267-78dd-4572-b99c-9781edf1a03b", "name": "79722852-e477-4e90-bf4d-de348b8f8c31_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "304e5081-f254-4df0-aae5-f92b694735e8", "name": "9c23987e-3fbd-447d-900b-dd0b801ca8c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e8bc5267-78dd-4572-b99c-9781edf1a03b"}}}]}, {"uuid": "604756e6-8f23-42e6-8335-c7165a48f07b", "name": "load_p1rlv13653_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c61a243-7736-46a0-a950-7cc811381158"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "304e5081-f254-4df0-aae5-f92b694735e8"}}}}, {"uuid": "95b6cfff-b677-446f-8b23-227e177a695b", "name": "48a93325-7a1d-4671-8fae-2adbe2094009_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "70026483-7529-4ffe-8f3b-b6cae4805814", "name": "4e95a876-9d1b-41a0-865f-9347f0ce019a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "95b6cfff-b677-446f-8b23-227e177a695b"}}}]}, {"uuid": "cacbe185-64b6-4e12-b4d8-3d92da57d657", "name": "load_p1rlv13653_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c61a243-7736-46a0-a950-7cc811381158"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "70026483-7529-4ffe-8f3b-b6cae4805814"}}}}, {"uuid": "4215e0af-da77-4d2e-a0be-8d321ac4f6d0", "name": "7ff3ae74-0d5b-45c6-b5dd-9a103a883b8c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82b2e12e-7a54-461c-9aeb-a222f058ec8e", "name": "8a57889c-3821-45cc-9438-a0a84fa702c4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4215e0af-da77-4d2e-a0be-8d321ac4f6d0"}}}]}, {"uuid": "b972ad59-d151-468c-bbd8-0fe62c96767f", "name": "load_p1rlv13654_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7be734c-88e2-42c1-8061-f4632bd05759"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "82b2e12e-7a54-461c-9aeb-a222f058ec8e"}}}}, {"uuid": "e3fd7e6b-3be9-468b-bb42-7a08e9ec8e27", "name": "e67ffab9-dfac-41eb-bbf4-9ebff2f3e456_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1fc8c2fb-8515-4441-b436-ab518d71744e", "name": "cb0ab9b6-7b48-4770-9f04-f90333d35c5e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e3fd7e6b-3be9-468b-bb42-7a08e9ec8e27"}}}]}, {"uuid": "d10b8868-8b0b-47ff-be2a-454a09676e6b", "name": "load_p1rlv13654_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7be734c-88e2-42c1-8061-f4632bd05759"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1fc8c2fb-8515-4441-b436-ab518d71744e"}}}}, {"uuid": "56b5f355-041e-4dba-ba09-03809c3c5b2e", "name": "a40afe02-c157-4c26-9cf8-bd7fa2dd4dd2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6323867069620042, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.40255171211713736, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "baeaae15-0168-4ba2-837d-7809208f82e6", "name": "7dd8ae54-e6f6-436b-a88f-4802f0aee048", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "56b5f355-041e-4dba-ba09-03809c3c5b2e"}}}]}, {"uuid": "349940a9-30e6-4bcf-b4ea-7dc077419d78", "name": "load_p1rlv13656_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8c0a04e-6e22-4da5-9907-7ae8097deb10"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "baeaae15-0168-4ba2-837d-7809208f82e6"}}}}, {"uuid": "b952e3d4-9a7c-40a3-9164-9d0dd955044a", "name": "8dc31abf-deda-4dfa-b7bf-e8f0ac40e338_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6323867069620042, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.40255171211713736, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c0c3b87a-70c4-4b94-b70b-f055b01e00b8", "name": "7196cb5a-f515-4eb5-aa7d-88db8da976a5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b952e3d4-9a7c-40a3-9164-9d0dd955044a"}}}]}, {"uuid": "37c16384-4d78-48e7-881c-0d1f7e0836e3", "name": "load_p1rlv13656_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8c0a04e-6e22-4da5-9907-7ae8097deb10"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c0c3b87a-70c4-4b94-b70b-f055b01e00b8"}}}}, {"uuid": "1f18b628-04c5-4373-aba7-c517e5f25cfd", "name": "286482c8-f090-4cae-8a2e-a73d7db99feb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3136780250521567, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6274781256964336, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "81b85d52-3498-43a8-936c-0438a3a1e77a", "name": "624e03d2-a2a3-40e9-a4ce-1cb0baf735ec", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1f18b628-04c5-4373-aba7-c517e5f25cfd"}}}]}, {"uuid": "65dd228a-3e18-4462-8f6e-0b8ef359f3c7", "name": "load_p1rlv13659_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "122e0772-7de6-4117-b1d3-caafbbbc8e22"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "81b85d52-3498-43a8-936c-0438a3a1e77a"}}}}, {"uuid": "4a0d6619-6653-4170-94df-7f94241e7756", "name": "e731fb7a-2aac-4405-9829-9a124878e978_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3136780250521567, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6274781256964336, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a9b8aef4-770c-4605-91fb-cf5f65bac8ad", "name": "cc3f61f1-61e1-4095-be99-dd251406fe77", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4a0d6619-6653-4170-94df-7f94241e7756"}}}]}, {"uuid": "869b76e9-b831-42f3-8bfe-4034fcee94b6", "name": "load_p1rlv13659_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "122e0772-7de6-4117-b1d3-caafbbbc8e22"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a9b8aef4-770c-4605-91fb-cf5f65bac8ad"}}}}, {"uuid": "1e3a44b0-0311-4a0a-920f-31d3cb8071ea", "name": "a6035deb-21e9-40d2-b1e3-5a81cf2ca1fa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.451252731053624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.713074208581691, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a7a72458-f0a7-4e0f-bab5-35516828e6fa", "name": "05101890-58cb-4a6a-998d-7a80d1a38c47", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1e3a44b0-0311-4a0a-920f-31d3cb8071ea"}}}]}, {"uuid": "aa4f58db-b7d9-429e-a7b8-d50bf374567d", "name": "load_p1rlv13660_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3d6fd13-2f04-4f23-97a3-cdf99159174c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a7a72458-f0a7-4e0f-bab5-35516828e6fa"}}}}, {"uuid": "f7ac0d69-63e9-40a3-81c8-4d9210203563", "name": "68272a3f-b73a-49ac-b04a-74e14740c79c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.451252731053624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.713074208581691, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b2a24286-1b0d-43bd-afe4-9a13c48cf1dd", "name": "9722d5dd-1118-4ef5-be44-6db735db2110", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f7ac0d69-63e9-40a3-81c8-4d9210203563"}}}]}, {"uuid": "d8533016-a154-475b-ae9b-fe6c0e150256", "name": "load_p1rlv13660_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3d6fd13-2f04-4f23-97a3-cdf99159174c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b2a24286-1b0d-43bd-afe4-9a13c48cf1dd"}}}}, {"uuid": "49b8597a-96da-4788-9afb-f420e2d395d7", "name": "f0537617-b121-403f-ba70-6877fc568219_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "16d19764-29c0-4188-95fd-b5ccbb16d11f", "name": "2e81f190-f3c8-4018-9677-fd85b083ba16", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "49b8597a-96da-4788-9afb-f420e2d395d7"}}}]}, {"uuid": "fd271e1a-15aa-4d19-ac28-1921b1f5a1a5", "name": "load_p1rlv13661_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ef8e6ec-86d3-429c-89b4-6c7260701e70"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "16d19764-29c0-4188-95fd-b5ccbb16d11f"}}}}, {"uuid": "6ee4c0dc-6e94-42a4-883c-00fe63e6c34a", "name": "758a5607-2d31-45ef-b75f-52aed25d24fd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ff2dc44d-7d99-4780-9681-ce8f29bd282b", "name": "0eefbf1a-f69c-4f42-a699-ea939db89f8c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6ee4c0dc-6e94-42a4-883c-00fe63e6c34a"}}}]}, {"uuid": "a56c3c6c-7ab4-4461-850f-b48a81dc968d", "name": "load_p1rlv13661_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ef8e6ec-86d3-429c-89b4-6c7260701e70"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ff2dc44d-7d99-4780-9681-ce8f29bd282b"}}}}, {"uuid": "f8133e03-31d5-42d7-bd88-4cc213bcb5b7", "name": "0ba1e3ee-b48a-4b3d-b892-f58040d5479b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2219087879829873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3595087789107823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "df9dad07-8131-40cb-9a8f-064c58479727", "name": "2f22329d-168a-44bd-9637-93fb93b0ccc0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8133e03-31d5-42d7-bd88-4cc213bcb5b7"}}}]}, {"uuid": "14568d59-4779-4b82-bd4c-7d6f84a4677a", "name": "load_p1rlv13662_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e55b944-ffad-47bf-8348-799afa4c7a1d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "df9dad07-8131-40cb-9a8f-064c58479727"}}}}, {"uuid": "50e89d97-6a00-4d85-8890-0efccc86d1d6", "name": "2fad6a38-3c6a-498d-9e60-183787ca00b4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2219087879829873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3595087789107823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4980cbef-343f-4f1c-8a0c-b1bb4d46f7a8", "name": "888f46ed-ff0c-4187-a262-a4883c066470", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "50e89d97-6a00-4d85-8890-0efccc86d1d6"}}}]}, {"uuid": "99b31d76-0371-49fb-aee3-ea5f640aca86", "name": "load_p1rlv13662_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e55b944-ffad-47bf-8348-799afa4c7a1d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4980cbef-343f-4f1c-8a0c-b1bb4d46f7a8"}}}}, {"uuid": "35f09a5f-e76d-4143-a0a1-6b6528905ecf", "name": "e92bb2ae-6b5b-4423-90a4-55f00d52ee1d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4037437915385973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5086059213404144, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c6cf5817-c9e9-42bd-8fa8-1d2f0deb9b7a", "name": "e9e871ed-52e9-4ea3-a1e7-ee2dce5ddc1d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "35f09a5f-e76d-4143-a0a1-6b6528905ecf"}}}]}, {"uuid": "69ddfb6d-3d94-4dab-81e2-68581c898457", "name": "load_p1rlv13663_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54887ca7-ae23-42d0-a715-aed8baa38ade"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c6cf5817-c9e9-42bd-8fa8-1d2f0deb9b7a"}}}}, {"uuid": "553e3b41-b83a-479c-9900-962640ead61c", "name": "8fdeee45-7875-4773-939f-6c2eededbcea_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4037437915385973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5086059213404144, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "00a29a22-4c22-47bf-bd3a-c7811900b5c7", "name": "15aea7ce-4acb-45f9-9a2d-6cec7461ff24", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "553e3b41-b83a-479c-9900-962640ead61c"}}}]}, {"uuid": "de470297-775d-41a9-a47c-c5d09e70a32c", "name": "load_p1rlv13663_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54887ca7-ae23-42d0-a715-aed8baa38ade"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "00a29a22-4c22-47bf-bd3a-c7811900b5c7"}}}}, {"uuid": "b93948c1-dbe7-4ace-bdfd-789dc22a235e", "name": "424fbac6-cc35-412a-8694-f8c7ff2dbe5d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.171921265639173, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.29621618517422543, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "370843e6-cc97-4f14-bd5d-71ce37f2fd6d", "name": "da0ddf58-b766-4b91-93f4-ce4eac28b240", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b93948c1-dbe7-4ace-bdfd-789dc22a235e"}}}]}, {"uuid": "f2fcf549-f097-41f8-8ff2-c5cee47e5668", "name": "load_p1rlv13664_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70cf02cc-8f1b-48ab-b9e6-50c3e58ad9ae"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "370843e6-cc97-4f14-bd5d-71ce37f2fd6d"}}}}, {"uuid": "3116d69b-7117-4fd8-b4e9-76d7811456b4", "name": "7fbb6319-51f4-447f-b58e-f3c627cbc17b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.171921265639173, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.29621618517422543, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a81205d-cea1-4b5b-bf2b-ef3f9c494db7", "name": "1681ffde-b20c-43e2-be25-1228adb048cb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3116d69b-7117-4fd8-b4e9-76d7811456b4"}}}]}, {"uuid": "e5513cae-ff8c-4f6a-82a0-f7fe9d4d4983", "name": "load_p1rlv13664_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70cf02cc-8f1b-48ab-b9e6-50c3e58ad9ae"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a81205d-cea1-4b5b-bf2b-ef3f9c494db7"}}}}, {"uuid": "561dd82a-ae45-4f18-b612-97489aafacb7", "name": "0510710f-c864-4bc0-a449-3dd4188e126d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6009666033769583, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.30487867399122176, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "298f4a0a-6d5a-4036-9050-3b41e1d5f3a5", "name": "fa52f6fb-68d6-49a3-a8ed-829fba2b4bfa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "561dd82a-ae45-4f18-b612-97489aafacb7"}}}]}, {"uuid": "f19c4f4e-5559-4646-b2ae-a189dca4a78e", "name": "load_p1rlv13666_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5868c24b-2a58-459b-8650-a6072241aca8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "298f4a0a-6d5a-4036-9050-3b41e1d5f3a5"}}}}, {"uuid": "2d6621c8-2e92-45df-b7e3-67b7c537e629", "name": "68f1ea3e-f95b-4303-b2a6-98908bdf41d3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6009666033769583, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.30487867399122176, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ce9c0f2e-efd6-4773-b074-1efb58ce18f8", "name": "2d068a03-d5cf-44f3-8e39-40e41e6e57b1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2d6621c8-2e92-45df-b7e3-67b7c537e629"}}}]}, {"uuid": "65c1c2bb-7594-4118-8ba2-bbd216d7ea0f", "name": "load_p1rlv13666_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5868c24b-2a58-459b-8650-a6072241aca8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ce9c0f2e-efd6-4773-b074-1efb58ce18f8"}}}}, {"uuid": "06e41b5d-b214-4e44-8975-b0649d93fe60", "name": "59d31c8d-fdd0-46b2-9502-0fd377ff435a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10b6ca4c-b522-4c46-a7f0-743befb358a6", "name": "a202078d-d353-405c-8692-4abd9581de19", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "06e41b5d-b214-4e44-8975-b0649d93fe60"}}}]}, {"uuid": "4f0a7fbd-d525-4b67-b610-ecc4dbc20dee", "name": "load_p1rlv13667_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d6cdd514-204d-4a86-b0f3-a9bc4990a2aa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10b6ca4c-b522-4c46-a7f0-743befb358a6"}}}}, {"uuid": "ac4210ab-7389-4005-a2ef-073ae6873999", "name": "d8bea9da-89f9-4072-860e-9420f53c46e6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e534cee0-6684-4f52-bc0e-6cd84309dc93", "name": "dea8c815-395b-4c6a-899d-054e1a145d92", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ac4210ab-7389-4005-a2ef-073ae6873999"}}}]}, {"uuid": "858e4943-fb33-4590-9ee4-155d15a843e1", "name": "load_p1rlv13667_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d6cdd514-204d-4a86-b0f3-a9bc4990a2aa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e534cee0-6684-4f52-bc0e-6cd84309dc93"}}}}, {"uuid": "c08997c7-db55-40c4-bf71-998de5dc6a71", "name": "9355b24d-6e65-4b80-8e20-c4cf4483930b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.243385388928283, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18185664736822973, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "843280bd-9358-4b99-85d7-c0dd09bf6f7b", "name": "8c70ecf7-eaa5-4b44-adf6-b23c782fbcc0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c08997c7-db55-40c4-bf71-998de5dc6a71"}}}]}, {"uuid": "823f5fdd-d975-4ec1-a4c5-7eb9e943a700", "name": "load_p1rlv13669_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "607d3b54-2cea-476b-afe2-ea40c6c02ddc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "843280bd-9358-4b99-85d7-c0dd09bf6f7b"}}}}, {"uuid": "669b92ac-4005-42e9-989d-1da0b09a1c0d", "name": "c9ff654e-5d95-48b2-9c5d-aaa5f5920f16_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.243385388928283, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18185664736822973, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "13843380-871f-4a44-97d5-19edb10e8cd1", "name": "7857066d-2d99-4610-9671-18cdf4e6d73f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "669b92ac-4005-42e9-989d-1da0b09a1c0d"}}}]}, {"uuid": "42d869a0-9001-4c85-96d5-1bd32d6d9a19", "name": "load_p1rlv13669_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "607d3b54-2cea-476b-afe2-ea40c6c02ddc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "13843380-871f-4a44-97d5-19edb10e8cd1"}}}}, {"uuid": "c824570f-41c3-4658-98ee-b5d38899b6fb", "name": "5420d868-605b-4836-9448-e01ad2898845_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ad43811a-0dce-48b2-8dad-193d26dc5c7e", "name": "94d0f2f7-b64e-4f42-9c92-9cbce5357977", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c824570f-41c3-4658-98ee-b5d38899b6fb"}}}]}, {"uuid": "4eec0c4e-00d7-4bec-949d-5a1648f8cc2e", "name": "load_p1rlv13670_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce53d307-fc73-487a-8f6a-3a0e0787bf79"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ad43811a-0dce-48b2-8dad-193d26dc5c7e"}}}}, {"uuid": "cd9f93af-ec5b-4d27-9244-d0d906a65dca", "name": "ddd68ff7-775d-4432-b32b-67e2f60fa9fa_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fadec189-327c-4c49-9a41-e9f44f088a90", "name": "f30ed151-47fc-40fe-9c37-0b39891ad867", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cd9f93af-ec5b-4d27-9244-d0d906a65dca"}}}]}, {"uuid": "3c0757fe-078a-4f99-9037-7bf31dd78c2c", "name": "load_p1rlv13670_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce53d307-fc73-487a-8f6a-3a0e0787bf79"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fadec189-327c-4c49-9a41-e9f44f088a90"}}}}, {"uuid": "cce1d914-3897-415d-94c9-0bda66e7584b", "name": "a9637591-c10b-4105-8b34-4ea3820ade8e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9288466752414104, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5041700498617779, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "83e11efa-0cb8-4d77-a6fb-48c4441831cd", "name": "c980a120-d7d0-4495-9d41-52fcb27a478c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cce1d914-3897-415d-94c9-0bda66e7584b"}}}]}, {"uuid": "a20a8092-569d-43be-b17c-299bca2d34fb", "name": "load_p1rlv13671_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2f95b8b-190c-4df2-9dd2-daee5efde34b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "83e11efa-0cb8-4d77-a6fb-48c4441831cd"}}}}, {"uuid": "98e84956-76ab-4a79-ac91-0c753fc10395", "name": "4ecc3f34-13d4-49e2-9636-c3822922023a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9288466752414104, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5041700498617779, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "406dfc6a-2106-4f9a-bb1a-e36b1874ac5c", "name": "865d5e0b-db3c-441b-a3ec-9d306b528262", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "98e84956-76ab-4a79-ac91-0c753fc10395"}}}]}, {"uuid": "05cffae3-c68a-4ca1-9c2c-6d472dcac594", "name": "load_p1rlv13671_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2f95b8b-190c-4df2-9dd2-daee5efde34b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "406dfc6a-2106-4f9a-bb1a-e36b1874ac5c"}}}}, {"uuid": "eac080d0-ce9f-4a11-9e89-064e9652e90a", "name": "5c0125ca-ef8b-4355-ad66-e1e6c40caf68_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c6d2010-b22f-4f29-a013-2e6988795d7b", "name": "80d25aa9-7fde-4ccf-a1b1-35cd5fab65b4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eac080d0-ce9f-4a11-9e89-064e9652e90a"}}}]}, {"uuid": "8d4e629f-b47d-4680-be3c-57609d082098", "name": "load_p1rlv13672_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32bec8ad-b312-4502-a2a1-6a4c9b2dd87a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c6d2010-b22f-4f29-a013-2e6988795d7b"}}}}, {"uuid": "029cbe02-f40e-47e9-8a6a-d7387d5abab2", "name": "50f4da33-f660-4b22-bf6b-fe34737078fb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3b0fd302-f287-459a-ae23-7476c857531f", "name": "a26442c2-5ac1-47c4-a2b3-b4ab086af933", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "029cbe02-f40e-47e9-8a6a-d7387d5abab2"}}}]}, {"uuid": "8a1bf579-c074-4fed-986e-85b6783e25cc", "name": "load_p1rlv13672_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32bec8ad-b312-4502-a2a1-6a4c9b2dd87a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3b0fd302-f287-459a-ae23-7476c857531f"}}}}, {"uuid": "693b4667-daea-4e40-bfff-dd1959206f97", "name": "fc721459-308e-4879-bc34-b613e7f7c85c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7935386970404408, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "55f52881-bd1e-4e64-92b8-eebaa9951c1d", "name": "d510a2f4-a1e2-4e21-af2f-a876e4b9c568", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "693b4667-daea-4e40-bfff-dd1959206f97"}}}]}, {"uuid": "e3e6f22c-25bc-4daa-ba19-48a3f4bf03d1", "name": "load_p1rlv13673_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9467d2d3-ad80-4bc7-aa9f-cd6e76494552"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "55f52881-bd1e-4e64-92b8-eebaa9951c1d"}}}}, {"uuid": "8fca9d32-1a27-4937-ab5d-7af131c409a2", "name": "0537dda4-bdba-4b71-b8b6-1d9426ed5389_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7935386970404408, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d8163229-e0c4-41cf-a995-7a616b434812", "name": "2c77a221-82e8-4961-ae91-366e528cbae6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8fca9d32-1a27-4937-ab5d-7af131c409a2"}}}]}, {"uuid": "189e9cc4-5dee-4a05-b818-18d261acbaf3", "name": "load_p1rlv13673_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9467d2d3-ad80-4bc7-aa9f-cd6e76494552"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d8163229-e0c4-41cf-a995-7a616b434812"}}}}, {"uuid": "cdcbb941-fd4c-47f7-99d4-b5833522ee8e", "name": "fcd8614f-b0c9-4179-a0bd-6de5a6d6295a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3711169311548215, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.698133467399761, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a39d1a35-4104-4eed-bd3a-065a7b917b55", "name": "ec8fff74-3bfd-4245-a89b-a6c8db3c0025", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cdcbb941-fd4c-47f7-99d4-b5833522ee8e"}}}]}, {"uuid": "a82d7413-7003-40aa-a574-389c577ecef9", "name": "load_p1rlv13675_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c532e298-bdd5-416e-8ebe-a082489ffee6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a39d1a35-4104-4eed-bd3a-065a7b917b55"}}}}, {"uuid": "f8c09000-4b28-45b6-a38a-de39aa272539", "name": "3bd3720d-ffed-4317-a656-460de94fe06e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3711169311548215, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.698133467399761, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8c8addae-8650-47cd-9563-df844c7de159", "name": "f50d2292-b086-4db1-8466-6afb06457711", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8c09000-4b28-45b6-a38a-de39aa272539"}}}]}, {"uuid": "60ee37ce-bbe8-486f-b6e2-c9b26c754bd1", "name": "load_p1rlv13675_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c532e298-bdd5-416e-8ebe-a082489ffee6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8c8addae-8650-47cd-9563-df844c7de159"}}}}, {"uuid": "0fff1cf9-f15e-4586-b11a-72f58c6f6003", "name": "a98e48cc-d122-4e98-a9c0-1fadf8c53d63_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3cc3a673-8856-4f3b-9c8f-f7daaa17fb65", "name": "cb431138-581d-4918-b0c8-cae906037191", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0fff1cf9-f15e-4586-b11a-72f58c6f6003"}}}]}, {"uuid": "b627c3b4-2b03-4e8f-a8be-61431fb5fd12", "name": "load_p1rlv13676_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8df1a69e-5b18-4eef-ab60-543a97257297"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3cc3a673-8856-4f3b-9c8f-f7daaa17fb65"}}}}, {"uuid": "6a22ceca-21eb-466d-9d9e-c24cc239af5d", "name": "742fed2a-5e6e-4add-9b6b-9ac27249fd3a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a0765586-2c2e-40b8-b1cf-e8c980220f17", "name": "7629d3d9-c942-4811-958e-2bd2ac62601e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6a22ceca-21eb-466d-9d9e-c24cc239af5d"}}}]}, {"uuid": "131c54ad-6996-45ed-96ad-bca519031e12", "name": "load_p1rlv13676_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8df1a69e-5b18-4eef-ab60-543a97257297"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a0765586-2c2e-40b8-b1cf-e8c980220f17"}}}}, {"uuid": "2159daa7-94bc-4a90-b7e3-9380fe01ef2f", "name": "95d4f202-1a21-460c-bb0e-64573f95dc6f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 12.611907582113087, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.885290064059574, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "526c56c3-9921-4fa4-a847-f1aaf7e2bf36", "name": "f0684b75-8c89-4aee-b462-56154d3d838e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2159daa7-94bc-4a90-b7e3-9380fe01ef2f"}}}]}, {"uuid": "38ef36d4-caaa-44ce-822a-172645112c72", "name": "load_p1rlv13677_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9aa7e62-8974-4ef0-aa5a-bcd545245aea"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "526c56c3-9921-4fa4-a847-f1aaf7e2bf36"}}}}, {"uuid": "d47e11d8-d612-4fd1-8682-c3435b00d0fa", "name": "38ec15b0-ee6b-4572-9bfb-3094e633a9c6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 12.611907582113087, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.885290064059574, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5adc2c36-14a6-47ba-8065-699e914c5cac", "name": "7715ca32-ff8b-41d5-b13e-652d37d6fbba", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d47e11d8-d612-4fd1-8682-c3435b00d0fa"}}}]}, {"uuid": "30eb92bc-4c73-40a8-b189-220ec402e1a5", "name": "load_p1rlv13677_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9aa7e62-8974-4ef0-aa5a-bcd545245aea"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5adc2c36-14a6-47ba-8065-699e914c5cac"}}}}, {"uuid": "13171c16-3766-48a6-b85d-fce1b4c23608", "name": "f1180b47-ce6c-459c-83e7-24fe85daf4e6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6b7e05ca-5d8d-4687-9c91-c46be0e94393", "name": "ced260df-4a12-44dd-880b-4d67e0c60293", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "13171c16-3766-48a6-b85d-fce1b4c23608"}}}]}, {"uuid": "b60bbcc8-db1c-4b2c-9ab8-17791087b760", "name": "load_p1rlv13678_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32b75c61-4e97-4e21-a786-8aab7a2d88f8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6b7e05ca-5d8d-4687-9c91-c46be0e94393"}}}}, {"uuid": "b62f2251-d24d-45e7-980e-ef4d9b47a504", "name": "1c1f827a-7066-412b-bf61-608d040d4916_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "56ae25bf-98c2-4005-ac11-543cc9eddeb7", "name": "d22d54e4-5e52-4472-8bf7-9a78ff6df048", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b62f2251-d24d-45e7-980e-ef4d9b47a504"}}}]}, {"uuid": "a0329e2e-1fa6-46e3-824e-c7da00ff962b", "name": "load_p1rlv13678_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32b75c61-4e97-4e21-a786-8aab7a2d88f8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "56ae25bf-98c2-4005-ac11-543cc9eddeb7"}}}}, {"uuid": "1216f196-6d86-4e3b-bda0-7366a867f755", "name": "02fab3ec-855e-490e-896f-7a706d20c1d4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5877230897388055, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4388767979233367, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f958ad87-2a98-4e6a-a293-8057d8fe389f", "name": "91e84414-0314-4efb-aba4-d8fed00ee89e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1216f196-6d86-4e3b-bda0-7366a867f755"}}}]}, {"uuid": "73b7d0ef-ca91-438c-868f-4ce161d78b94", "name": "load_p1rlv13679_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "284bbc5d-bb49-404d-823e-08ec543c90b8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f958ad87-2a98-4e6a-a293-8057d8fe389f"}}}}, {"uuid": "97ce0ac1-19b9-4960-8f86-e49ce43b4fdd", "name": "15a4960a-ad64-43bb-8715-67624839e8bb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5877230897388055, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4388767979233367, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a345b66d-51c6-4718-92d2-1e66017171ec", "name": "646d7312-411e-4fa8-8089-802c3b8ac94a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "97ce0ac1-19b9-4960-8f86-e49ce43b4fdd"}}}]}, {"uuid": "f5ffe810-c070-4042-bd16-a1d1047e555d", "name": "load_p1rlv13679_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "284bbc5d-bb49-404d-823e-08ec543c90b8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a345b66d-51c6-4718-92d2-1e66017171ec"}}}}, {"uuid": "c8b1c45d-d4d0-4928-935c-3866c5267d73", "name": "fc9cbd12-67da-4ddf-9e17-a4cc9d3d7a39_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "90e84820-53f8-4ec5-ab30-c1b8adeba609", "name": "a6367165-e64e-4785-83c4-49e85d650317", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c8b1c45d-d4d0-4928-935c-3866c5267d73"}}}]}, {"uuid": "0fb1c0b4-f597-4755-9070-7a24b5f8b93a", "name": "load_p1rlv13680_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85b910cd-def8-41d8-ad47-3c074a54ad8d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "90e84820-53f8-4ec5-ab30-c1b8adeba609"}}}}, {"uuid": "24e8ad5a-5435-4bd3-a930-36188d2f4313", "name": "0a87ea87-5580-41e4-a52e-41639b7d996c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ea4d6a04-3fdf-4e82-baad-0269aed2b904", "name": "996cd32f-f05e-4470-b8d1-10acdbd6854d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "24e8ad5a-5435-4bd3-a930-36188d2f4313"}}}]}, {"uuid": "21437a63-b495-4b76-876c-e5f86f7be7fc", "name": "load_p1rlv13680_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85b910cd-def8-41d8-ad47-3c074a54ad8d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ea4d6a04-3fdf-4e82-baad-0269aed2b904"}}}}, {"uuid": "6632eb7e-bae8-4711-8280-ac3a0a991206", "name": "28893ff5-412e-40a3-a212-52e2782d34ef_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "000ac7b0-24c3-4950-972d-e20658228342", "name": "8afd517a-a595-4d9f-b888-4b98d003878a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6632eb7e-bae8-4711-8280-ac3a0a991206"}}}]}, {"uuid": "369fe88d-458f-495d-a6fc-e2299dcaa1d3", "name": "load_p1rlv13681_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60f08cde-51d3-4b51-9ab5-b61c8043950f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "000ac7b0-24c3-4950-972d-e20658228342"}}}}, {"uuid": "73ed9a9b-8b1c-4d72-997d-3b3f06174e72", "name": "d307541e-6390-420b-90bc-c354842c8c4e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ad96ba65-d3c8-4412-a032-176eab395487", "name": "6105ce88-9320-477f-b2d2-85e6dd5ad86d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "73ed9a9b-8b1c-4d72-997d-3b3f06174e72"}}}]}, {"uuid": "82b351e5-a3aa-47e2-9520-cc902c46a692", "name": "load_p1rlv13681_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60f08cde-51d3-4b51-9ab5-b61c8043950f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ad96ba65-d3c8-4412-a032-176eab395487"}}}}, {"uuid": "865ddcf7-98d3-41f6-bf38-defee83d97b8", "name": "7ed0c62d-bcff-4b32-a663-d21ae0bf8ac3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5757409771642927, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7652901499575055, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "059b3c81-83a8-4bb0-8f63-a8de9452fb9b", "name": "4fffba48-2ddb-4844-95b5-c2808665038f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "865ddcf7-98d3-41f6-bf38-defee83d97b8"}}}]}, {"uuid": "629d17c4-bebd-48c9-879e-0c0e033ca412", "name": "load_p1rlv13682_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a3c050c-cc0d-460e-af02-ce3421431474"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "059b3c81-83a8-4bb0-8f63-a8de9452fb9b"}}}}, {"uuid": "1295811e-de6a-44ad-a13e-dda7e4e2cf61", "name": "9152cc72-9051-4239-b8f0-9b3dc8e0a72a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5757409771642927, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7652901499575055, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "591fd267-9404-4294-ae61-8c65df29bcb9", "name": "330bb019-c54a-4ecb-a332-7035a124455b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1295811e-de6a-44ad-a13e-dda7e4e2cf61"}}}]}, {"uuid": "47422c8c-3417-4dac-9c86-ffc9609bda7c", "name": "load_p1rlv13682_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a3c050c-cc0d-460e-af02-ce3421431474"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "591fd267-9404-4294-ae61-8c65df29bcb9"}}}}, {"uuid": "0db7c061-169a-4013-b150-b5f93a5140e5", "name": "b70b337e-55a5-4def-a326-eaaf47f57728_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5877230897388055, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4388767979233367, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "872b1bac-ff07-4d30-adf6-317dd41a1de5", "name": "2675fd69-b097-4d9b-9475-e2f3719c7a70", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0db7c061-169a-4013-b150-b5f93a5140e5"}}}]}, {"uuid": "668da774-22b3-42e2-a6b1-0280c9816f6a", "name": "load_p1rlv13683_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "de45dc59-3e0a-4b33-8cf4-d5213b0140c1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "872b1bac-ff07-4d30-adf6-317dd41a1de5"}}}}, {"uuid": "0e2ad523-f99c-4929-8d16-91ef3629506b", "name": "07fbfeaa-dc3a-4b54-b01e-0afb2c1c0371_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5877230897388055, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4388767979233367, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "54c1eeed-950d-4379-b00d-847f964c7ac4", "name": "d63dc4c7-07a6-4451-b606-6641acdcc48a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0e2ad523-f99c-4929-8d16-91ef3629506b"}}}]}, {"uuid": "ee5e2946-2306-4eaa-af5e-901222eea510", "name": "load_p1rlv13683_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "de45dc59-3e0a-4b33-8cf4-d5213b0140c1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "54c1eeed-950d-4379-b00d-847f964c7ac4"}}}}, {"uuid": "aa9fa668-8b5c-4c16-aa75-31f5d381c321", "name": "be235377-0688-4d31-a2cf-c9e6c94bc6e7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5202593896091736, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6973445820856009, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c859be38-862f-42d2-8694-e366a9f2128c", "name": "84e237c2-c2a7-4aa4-b35b-8229b8b5a493", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aa9fa668-8b5c-4c16-aa75-31f5d381c321"}}}]}, {"uuid": "f5fe6a40-9cf3-4744-bef2-05e7f64a97fc", "name": "load_p1rlv13684_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ec49353-14d1-4917-83bc-ca62cd94bf30"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c859be38-862f-42d2-8694-e366a9f2128c"}}}}, {"uuid": "2cd83c37-2373-4eda-af9a-c268cdd40bba", "name": "4b4456a7-c3f4-4a2e-88af-a0635f507705_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5202593896091736, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6973445820856009, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d89384a1-0e1f-41bf-8082-168c05d69b38", "name": "45cc88fb-5813-44e0-b1f4-9cd14a9451bc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2cd83c37-2373-4eda-af9a-c268cdd40bba"}}}]}, {"uuid": "6397bd60-fbca-423c-aaae-fe883c0a045e", "name": "load_p1rlv13684_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ec49353-14d1-4917-83bc-ca62cd94bf30"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d89384a1-0e1f-41bf-8082-168c05d69b38"}}}}, {"uuid": "c1bedbde-cb3b-48cf-83a8-2820a7cbe371", "name": "efdbfcfc-3608-4192-8ee7-1f4bfb75171f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3a9035cd-3ef0-4eb6-a016-ddba363a86a7", "name": "b77753f9-7255-4fa0-8139-9968b8f1520b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c1bedbde-cb3b-48cf-83a8-2820a7cbe371"}}}]}, {"uuid": "19754d34-82fa-46dd-84ee-d2646d6b799d", "name": "load_p1rlv13685_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f777bc74-e6f3-4e80-bb72-0764964db21e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3a9035cd-3ef0-4eb6-a016-ddba363a86a7"}}}}, {"uuid": "71467a1e-1ede-47b9-9bfd-85c4bac34c8f", "name": "4704cf25-87d5-43f7-83d1-c6088b025dd4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "36f533fa-a479-4daa-b3e0-5a2c5dbb51c3", "name": "3006d40c-9556-418a-aab0-e2444e2207a5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "71467a1e-1ede-47b9-9bfd-85c4bac34c8f"}}}]}, {"uuid": "3eabe4a1-6c61-4686-922c-e3a0e40af83e", "name": "load_p1rlv13685_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f777bc74-e6f3-4e80-bb72-0764964db21e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "36f533fa-a479-4daa-b3e0-5a2c5dbb51c3"}}}}, {"uuid": "94e6fa50-42fc-41e9-9abb-201d8e23d94f", "name": "fa86f889-dfcb-41a6-8f73-d9d7d90bf208_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ebee099f-241a-4c7d-b75d-2058d800889d", "name": "a9495890-1185-489f-b8c4-26fb7b1d0232", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "94e6fa50-42fc-41e9-9abb-201d8e23d94f"}}}]}, {"uuid": "91bc007c-1af6-48a0-a5e6-d8f0d37d137e", "name": "load_p1rlv13686_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60fe0a16-aa4d-4fe8-9f39-81bfa13b505f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ebee099f-241a-4c7d-b75d-2058d800889d"}}}}, {"uuid": "1112faee-e8b7-4260-880a-43e211c9ced0", "name": "39a3bdc6-ca82-438b-b699-d645d3ca387a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c9a78a4-19b6-4b48-9b0f-f5d183778f42", "name": "c339dea3-5781-414f-9f68-233cf2e25740", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1112faee-e8b7-4260-880a-43e211c9ced0"}}}]}, {"uuid": "d3c9ea73-77eb-488a-b9c1-b52499a39dba", "name": "load_p1rlv13686_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60fe0a16-aa4d-4fe8-9f39-81bfa13b505f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c9a78a4-19b6-4b48-9b0f-f5d183778f42"}}}}, {"uuid": "0f1e6ac0-70aa-4af0-a939-10d6bcc816b0", "name": "94db7979-8999-44bf-bf37-2b918522fb47_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4786893203254163, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3666592754227633, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8de6b990-1453-4ed8-abf9-d39634ea2aee", "name": "dacc3adb-a90c-4aea-b34a-559baea1c165", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0f1e6ac0-70aa-4af0-a939-10d6bcc816b0"}}}]}, {"uuid": "62d4d493-6a6b-41cd-ba20-e0f18e875b39", "name": "load_p1rlv13687_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4671f981-e26e-4f26-9698-7f9068ce6dec"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8de6b990-1453-4ed8-abf9-d39634ea2aee"}}}}, {"uuid": "332f9759-59a9-4733-84d5-01ddeb74945d", "name": "ab8b8986-c290-4ceb-8151-476952ad0e4f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4786893203254163, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3666592754227633, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "df94fbb6-0cd0-4e7a-8a43-22c6ff208d97", "name": "bc05459c-41f7-465c-a4a3-e1c5fd8cec2a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "332f9759-59a9-4733-84d5-01ddeb74945d"}}}]}, {"uuid": "29645c13-d3d0-4b4c-bbbf-afd5222598a3", "name": "load_p1rlv13687_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4671f981-e26e-4f26-9698-7f9068ce6dec"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "df94fbb6-0cd0-4e7a-8a43-22c6ff208d97"}}}}, {"uuid": "bd4ddb24-8e29-4b96-af3b-96f25a7494de", "name": "1319ad49-c4e4-44ac-9f97-597c74220ab2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7344cd86-6533-4184-a373-c02ab9549fca", "name": "332dc737-3c56-4c9e-bef6-ea2937774ea8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bd4ddb24-8e29-4b96-af3b-96f25a7494de"}}}]}, {"uuid": "4e62be72-5efb-4974-b102-b27fd9db4d5a", "name": "load_p1rlv13689_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e5db11f-0418-4119-9c71-26619456fd7b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7344cd86-6533-4184-a373-c02ab9549fca"}}}}, {"uuid": "5f414c6b-8fd3-4126-bd2a-bb61f3c48abe", "name": "d83021b0-7f17-4b5c-b199-976f49090c11_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "efbe0b52-16e1-4632-9ca6-3f01d3a7c2f6", "name": "4ccaf277-0aec-4dce-bdd6-8036eab4f00f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5f414c6b-8fd3-4126-bd2a-bb61f3c48abe"}}}]}, {"uuid": "392ed64a-44d5-409a-bcb8-7b53d7cb16be", "name": "load_p1rlv13689_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e5db11f-0418-4119-9c71-26619456fd7b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "efbe0b52-16e1-4632-9ca6-3f01d3a7c2f6"}}}}, {"uuid": "3200f720-b710-45ce-9dcf-f6448fe8fb4f", "name": "6f5a230a-2bc8-448d-ad0c-ca40306ac670_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "63d99ad2-499f-4001-8c6b-02d3b68cf97a", "name": "57e7ef2c-f725-4c38-a0d1-37ad2dc3eecf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3200f720-b710-45ce-9dcf-f6448fe8fb4f"}}}]}, {"uuid": "9530d4ad-f493-4ae8-b3f2-3e303d647d75", "name": "load_p1rlv13690_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "71c26ca3-0d61-46b8-a95b-710e0b760b62"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "63d99ad2-499f-4001-8c6b-02d3b68cf97a"}}}}, {"uuid": "7823cc66-5ff2-4c20-ab5d-91512e9d2c41", "name": "833ab35f-38f3-4673-b957-be716b6dcec7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2e2346ec-1d8b-496c-8acb-0feed9154b43", "name": "b15f16e7-cad3-4f3e-ae5f-129f399a4890", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7823cc66-5ff2-4c20-ab5d-91512e9d2c41"}}}]}, {"uuid": "bf76abe8-4b18-41e3-af4e-b76279eb2699", "name": "load_p1rlv13690_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "71c26ca3-0d61-46b8-a95b-710e0b760b62"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2e2346ec-1d8b-496c-8acb-0feed9154b43"}}}}, {"uuid": "e1737a50-5fd7-4b33-870f-d5b087c76427", "name": "fb5a4aa2-45c2-4ab6-9c67-965f1b1d50cb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7ba0cafd-5471-4410-a509-d82014858abd", "name": "ac7f08f8-7179-400f-9966-1643b06fc540", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e1737a50-5fd7-4b33-870f-d5b087c76427"}}}]}, {"uuid": "4b3eeef6-2fdc-4483-9a15-7d8a4f1f2ed0", "name": "load_p1rlv13691_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "850df31b-ee95-4903-93b7-6e5911e8f8a0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7ba0cafd-5471-4410-a509-d82014858abd"}}}}, {"uuid": "2ae22984-622d-4a1d-85f5-ce7064c1ae74", "name": "3cc735fc-385d-43f0-a35a-333df4a3392b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "124668c6-413a-4b80-bdda-2c889f127fc4", "name": "18b11031-e37c-4533-a5ae-8f60821f73cd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2ae22984-622d-4a1d-85f5-ce7064c1ae74"}}}]}, {"uuid": "24ccb9aa-e453-4fad-a5c8-1e8a306ff1eb", "name": "load_p1rlv13691_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "850df31b-ee95-4903-93b7-6e5911e8f8a0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "124668c6-413a-4b80-bdda-2c889f127fc4"}}}}, {"uuid": "3df4c39e-8ae1-4947-b3bc-19df9c776026", "name": "f6f6fdb3-fe43-4c07-8b28-4962430c7165_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.1140699739098325, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.0691290550182753, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9644c026-329a-4a1f-998b-60ece9776419", "name": "1f5df881-3b77-4b4a-bd21-a995d244dd40", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3df4c39e-8ae1-4947-b3bc-19df9c776026"}}}]}, {"uuid": "92ded483-725f-40c6-84b3-98a6015cec71", "name": "load_p1rlv13692_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "091b545a-eb31-4bea-a0a6-5aa9c7a8397f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9644c026-329a-4a1f-998b-60ece9776419"}}}}, {"uuid": "d509bf1b-6112-4ef3-8154-002006554632", "name": "8079b172-9551-4da3-afd7-57c2a2d1d119_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.1140699739098325, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.0691290550182753, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "272b06f6-e51d-4f01-8e44-3e9511586061", "name": "f002eb9c-8fd9-40ef-bda6-b972d6ca4b2b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d509bf1b-6112-4ef3-8154-002006554632"}}}]}, {"uuid": "e1bfcb4c-83c9-4e63-a718-ede158d8b3a9", "name": "load_p1rlv13692_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "091b545a-eb31-4bea-a0a6-5aa9c7a8397f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "272b06f6-e51d-4f01-8e44-3e9511586061"}}}}, {"uuid": "f549d4ee-7d2c-458a-8865-413d3613ff12", "name": "eb9d67ed-dbaf-4e6a-aa5f-36a91f666e0b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e41d8d1c-8dd4-4bf2-a16c-50fca8aa045e", "name": "2830747a-ac37-40dc-8c02-935d3b9912ec", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f549d4ee-7d2c-458a-8865-413d3613ff12"}}}]}, {"uuid": "d55f90b8-e894-4da7-860a-3958326632e3", "name": "load_p1rlv13693_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5815b75-1226-4221-9bcb-bc75ce85fa17"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e41d8d1c-8dd4-4bf2-a16c-50fca8aa045e"}}}}, {"uuid": "476a69e1-a9e0-4928-b7f3-552cc90bf303", "name": "38c60878-bd82-4df7-848f-9985598f5fe7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "655ebaf4-0818-4331-ae7d-7146bedafebc", "name": "1ab0c66e-95fd-4115-80fd-a9db9b12c908", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "476a69e1-a9e0-4928-b7f3-552cc90bf303"}}}]}, {"uuid": "149e6a50-bc4c-437f-9e56-86146effe61a", "name": "load_p1rlv13693_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5815b75-1226-4221-9bcb-bc75ce85fa17"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "655ebaf4-0818-4331-ae7d-7146bedafebc"}}}}, {"uuid": "a62dc22d-1f8d-46b2-8556-ca0dc332c559", "name": "8e6a59bb-fad2-4318-9066-580c5077702b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8bd92f03-a0f4-48ce-9b3d-09bffcd2412d", "name": "6557eb3f-9fea-4473-a24d-7b4ce0e44fc6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a62dc22d-1f8d-46b2-8556-ca0dc332c559"}}}]}, {"uuid": "4a37d94a-f80d-47e0-b65b-01e2960318e1", "name": "load_p1rlv13694_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1de2ebf2-3207-4bf7-9702-4c729d99a6cf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8bd92f03-a0f4-48ce-9b3d-09bffcd2412d"}}}}, {"uuid": "71d8bcb0-42da-4718-bf2d-e7d363ead5c4", "name": "a96590fd-adbb-41d9-a01a-98631e5a4933_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aa9a819d-caee-485b-88bf-f4ae3727b769", "name": "b739da1c-6f92-41cb-81d2-12f6cbf701d1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "71d8bcb0-42da-4718-bf2d-e7d363ead5c4"}}}]}, {"uuid": "9b9c8591-0453-4c68-bf4a-37c70b29ae2f", "name": "load_p1rlv13694_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1de2ebf2-3207-4bf7-9702-4c729d99a6cf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aa9a819d-caee-485b-88bf-f4ae3727b769"}}}}, {"uuid": "09c4d5f1-71c4-469b-8603-f1b25c00d631", "name": "4c485e30-41bd-4083-8717-dbc40101c2f3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.17188390355877, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.554870220420769, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a3ee682c-b1c7-44c4-bff6-a4d8acad378c", "name": "d6029c33-cd14-49e9-888f-548ed4366560", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "09c4d5f1-71c4-469b-8603-f1b25c00d631"}}}]}, {"uuid": "4f0a34ae-c8fc-44bd-9c7c-c804db865c3b", "name": "load_p1rlv13695_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d73963d7-acf4-48b3-8e54-6ee9f403d36f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a3ee682c-b1c7-44c4-bff6-a4d8acad378c"}}}}, {"uuid": "a14f6598-dcf3-4222-aff9-03aa785c3232", "name": "7324e4d5-eff6-4b91-8842-ad45bb36e2fb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.17188390355877, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.554870220420769, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "38fd2fc8-af2c-4375-bb14-2735753fd5ba", "name": "01c38178-5c60-4a27-b3b1-b8c4762989e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a14f6598-dcf3-4222-aff9-03aa785c3232"}}}]}, {"uuid": "ae6c0fd0-d614-4c0f-90ef-5fc0b3295f59", "name": "load_p1rlv13695_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d73963d7-acf4-48b3-8e54-6ee9f403d36f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "38fd2fc8-af2c-4375-bb14-2735753fd5ba"}}}}, {"uuid": "5eb73892-27e2-4054-8588-b0de1be5cdee", "name": "a3430b8f-8606-44be-b936-cc51b83628d6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.170918611307458, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.575413421893771, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e031df21-cbfa-4b1e-8a85-d904674671a8", "name": "a35ed688-1237-412d-8710-5425de3c9f82", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5eb73892-27e2-4054-8588-b0de1be5cdee"}}}]}, {"uuid": "cab9456a-bb12-404e-a3a4-c1d4a783098f", "name": "load_p1rlv13696_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f92273c9-90b8-4819-b036-9d69afb5aed6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e031df21-cbfa-4b1e-8a85-d904674671a8"}}}}, {"uuid": "ae2a96b5-8402-4705-b3ef-47eb2956246d", "name": "aebf8306-45df-47e3-8094-e02d25e14710_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.170918611307458, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.575413421893771, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "545bb6e9-937c-4335-8831-35cbfa5fc324", "name": "b7f7404f-11dd-4e22-8878-ad6ae3c5a2ca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ae2a96b5-8402-4705-b3ef-47eb2956246d"}}}]}, {"uuid": "0125f75c-efd6-4957-8ac0-1e8d533a3b87", "name": "load_p1rlv13696_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f92273c9-90b8-4819-b036-9d69afb5aed6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "545bb6e9-937c-4335-8831-35cbfa5fc324"}}}}, {"uuid": "483eaae2-214c-421b-b39c-b03f28d630fe", "name": "6bfb24b7-09c7-4f6c-a33c-d67aea19d82a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2370181650987906, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5806603708512078, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6e1fad86-4bfd-4d5f-8057-b77f7ec6b87f", "name": "6872893f-2e86-4889-9cf0-3945d3f9b966", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "483eaae2-214c-421b-b39c-b03f28d630fe"}}}]}, {"uuid": "fe5131a4-e117-4bfc-8606-a1410341e010", "name": "load_p1rlv13697_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c808261e-a49e-4954-bdc4-a8b63d0ee25b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6e1fad86-4bfd-4d5f-8057-b77f7ec6b87f"}}}}, {"uuid": "8a9fb659-c0b2-49a0-9cbc-4c1489f3ddbd", "name": "e2f294d7-0cb7-467e-89cf-090a4f35106e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2370181650987906, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5806603708512078, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b6121fa9-05bb-4af6-ace7-6219736b9224", "name": "e6ad07be-0efa-4e50-8ae6-c3e29b1d6a86", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a9fb659-c0b2-49a0-9cbc-4c1489f3ddbd"}}}]}, {"uuid": "05f1dfea-f98f-4ad7-b5f1-125332718265", "name": "load_p1rlv13697_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c808261e-a49e-4954-bdc4-a8b63d0ee25b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b6121fa9-05bb-4af6-ace7-6219736b9224"}}}}, {"uuid": "994053b2-2dcd-4e45-99c1-0143b8d3a3f4", "name": "9633f640-6a82-4afc-8062-185d65b30729_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cac11212-2c59-40b9-a2a9-c754625bb9fe", "name": "38b59a81-9591-40cb-ab35-f1578767f4a6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "994053b2-2dcd-4e45-99c1-0143b8d3a3f4"}}}]}, {"uuid": "cf7355e4-9d2e-4ae6-9384-4cbac3892452", "name": "load_p1rlv13698_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3839c291-3f45-46c3-973f-6a9615fcf81b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cac11212-2c59-40b9-a2a9-c754625bb9fe"}}}}, {"uuid": "48520c39-4eb5-43e5-86ce-ee13fd69508b", "name": "879b2b6d-5a7e-43a3-b01d-cf1172000d71_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1a354e32-b9f7-48a2-9d67-16babb502626", "name": "62fd14d7-3f51-4606-8237-98874714c9e6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "48520c39-4eb5-43e5-86ce-ee13fd69508b"}}}]}, {"uuid": "3be1397a-8a05-4668-9b09-656b568aab4b", "name": "load_p1rlv13698_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3839c291-3f45-46c3-973f-6a9615fcf81b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1a354e32-b9f7-48a2-9d67-16babb502626"}}}}, {"uuid": "29c3eb53-e8e6-434d-b8b9-b5d0eeeef957", "name": "f2b3afb2-d9d1-4df0-bc47-cb542a352e1a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9800785435301127, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2597629929517743, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "efea7d55-d9c3-40d8-9974-1ec710094411", "name": "fdc6bcae-ed53-44fc-a78d-8e226ddf0975", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "29c3eb53-e8e6-434d-b8b9-b5d0eeeef957"}}}]}, {"uuid": "78ea114e-84ee-4615-baf9-4817aefbf5b8", "name": "load_p1rlv13700_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ecf9ee9-2a3c-431b-84c8-02c7c7aaacb1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "efea7d55-d9c3-40d8-9974-1ec710094411"}}}}, {"uuid": "3ac6bc75-465b-42b3-852e-eeb5e2d1037e", "name": "501c5d20-904e-4849-b8b3-9edea9c96d6e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9800785435301127, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2597629929517743, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "396a415b-295f-4d6d-962d-c35b69dbfb00", "name": "6233a0aa-0d77-4a61-a4d0-eea1dbb1ac97", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3ac6bc75-465b-42b3-852e-eeb5e2d1037e"}}}]}, {"uuid": "e240f08b-a2bd-43ef-9bc3-418489941ef9", "name": "load_p1rlv13700_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ecf9ee9-2a3c-431b-84c8-02c7c7aaacb1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "396a415b-295f-4d6d-962d-c35b69dbfb00"}}}}, {"uuid": "c7596c6f-33bf-4ce8-94b7-ce8450625e3e", "name": "7fa0faeb-9e91-41c9-a0ee-8f12863cd6ec_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.547211686956079, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18814377021524833, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e3af9236-7fa2-4281-89b0-939b2cc9f155", "name": "dc89826e-cbd4-4e83-a5dd-8763bef64cb9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c7596c6f-33bf-4ce8-94b7-ce8450625e3e"}}}]}, {"uuid": "eb4e4727-b4f0-46ec-826a-dbb1737983cb", "name": "load_p1rlv13701_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa7a324e-d367-49a5-820a-b18e72243265"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e3af9236-7fa2-4281-89b0-939b2cc9f155"}}}}, {"uuid": "64f28cd5-6b3a-49ee-b88b-876bf0d5f347", "name": "a33c02eb-f545-461b-bc95-84d092c7914e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.547211686956079, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18814377021524833, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "83710f86-c125-4c89-92ad-3a6ded5b40b9", "name": "e727b800-0e89-42c7-8c25-e590764f428a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "64f28cd5-6b3a-49ee-b88b-876bf0d5f347"}}}]}, {"uuid": "deae30e2-4d1e-4e45-92b3-0d11ee422fcb", "name": "load_p1rlv13701_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa7a324e-d367-49a5-820a-b18e72243265"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "83710f86-c125-4c89-92ad-3a6ded5b40b9"}}}}, {"uuid": "700b9b2f-11c3-4d94-b9b7-14206f86098b", "name": "ec7828bd-32bf-4859-b88f-9d00dbada00e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "13bab12d-d6b7-45e9-ba69-182dcf8a0a9b", "name": "741e51a1-eebf-437e-91ba-84cc74e720fc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "700b9b2f-11c3-4d94-b9b7-14206f86098b"}}}]}, {"uuid": "6a27aee9-62a0-48e0-a446-8b3d4f3219e7", "name": "load_p1rlv13702_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fe3c958-296f-4b51-8b2b-74bb34ddb5a6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "13bab12d-d6b7-45e9-ba69-182dcf8a0a9b"}}}}, {"uuid": "a9754e34-ddf1-4994-8ce0-4913a3e58681", "name": "b0090678-8998-4d48-a463-dd05e6730437_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "936f4ea1-214f-4414-8b34-6ce0bf9879d7", "name": "54c22d49-2d81-4419-89f9-1ad89c5904de", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a9754e34-ddf1-4994-8ce0-4913a3e58681"}}}]}, {"uuid": "b405cc7f-aac6-4979-b0e8-4bc67aaf6e2e", "name": "load_p1rlv13702_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fe3c958-296f-4b51-8b2b-74bb34ddb5a6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "936f4ea1-214f-4414-8b34-6ce0bf9879d7"}}}}, {"uuid": "ad6f3996-5250-4903-900c-98cc80721468", "name": "e8a90a05-9c86-433f-a9ad-9ad3bb2f8b82_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2769071780208345, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4029118207034132, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "95c019d8-e7bf-4afd-a080-a6f621649229", "name": "05eeeca4-83c7-4501-b26c-d31da230df29", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ad6f3996-5250-4903-900c-98cc80721468"}}}]}, {"uuid": "3dab6f65-4632-4a3b-b353-50d00476b9c7", "name": "load_p1rlv13703_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9efacf5-5b96-4670-b6f1-dc398485cde9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "95c019d8-e7bf-4afd-a080-a6f621649229"}}}}, {"uuid": "97c46857-975d-412a-a4e0-5809874f5c16", "name": "ecb942cd-9b32-4043-b0e8-dc7a236faee7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2769071780208345, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4029118207034132, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f5e1e662-9c2f-48a5-85fb-d172280f7787", "name": "a31d2e6f-e64f-4b3d-b7d7-d3bb98c08c73", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "97c46857-975d-412a-a4e0-5809874f5c16"}}}]}, {"uuid": "bcb30f07-f390-431a-9ff8-0cde94b4035a", "name": "load_p1rlv13703_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9efacf5-5b96-4670-b6f1-dc398485cde9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f5e1e662-9c2f-48a5-85fb-d172280f7787"}}}}, {"uuid": "67e20fc8-11d1-4dc4-b232-49a9104fdd94", "name": "ddfc1f7d-1036-4cfa-9a48-fa1ba44fd782_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5d75438e-9f5d-481a-973d-ae138fa0337f", "name": "5fc81374-3427-4e96-8835-d0eb39e298a4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "67e20fc8-11d1-4dc4-b232-49a9104fdd94"}}}]}, {"uuid": "3b180503-e355-4f5c-9e1e-c2dca49a1d38", "name": "load_p1rlv13705_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f409299-5ac0-4f31-a217-d0aef7fbc4d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5d75438e-9f5d-481a-973d-ae138fa0337f"}}}}, {"uuid": "4b785ece-1a3a-4873-93a0-aaff723e54ea", "name": "26668d8a-2dbe-4359-a6bb-451d9a76228c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0b47fcab-65b9-4a82-b1bb-a2a21beb6138", "name": "903b60ff-3b21-4883-8b18-faae551c3d75", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4b785ece-1a3a-4873-93a0-aaff723e54ea"}}}]}, {"uuid": "284635fd-7a8a-4cf2-b20e-40b17b78ba7b", "name": "load_p1rlv13705_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f409299-5ac0-4f31-a217-d0aef7fbc4d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0b47fcab-65b9-4a82-b1bb-a2a21beb6138"}}}}, {"uuid": "c19162f1-9baa-4f3a-8e29-091896a65a63", "name": "44433df7-721c-49f3-9d4a-3f79a6898b62_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "49ba3689-a5c8-4f05-88d4-29a5f9a32264", "name": "bc6dd17f-97b0-46bb-b18d-a96ac1e78365", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c19162f1-9baa-4f3a-8e29-091896a65a63"}}}]}, {"uuid": "6ffcabfc-6189-4923-9459-f810143a516a", "name": "load_p1rlv13706_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e60fc98a-9c1d-4975-a9b9-e37271b4ac81"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "49ba3689-a5c8-4f05-88d4-29a5f9a32264"}}}}, {"uuid": "43c584f4-0f3c-4289-bee3-b8198dccaf4d", "name": "4807c297-4619-4dbb-ac3a-93b5cd05776e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ee8dd868-18b6-4d0f-881b-f0cc44f0ca24", "name": "d7cfc5db-df8b-4faa-ab3e-40d38ee914fa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "43c584f4-0f3c-4289-bee3-b8198dccaf4d"}}}]}, {"uuid": "bc3cf296-500e-48df-8860-073864e4dd2b", "name": "load_p1rlv13706_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e60fc98a-9c1d-4975-a9b9-e37271b4ac81"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ee8dd868-18b6-4d0f-881b-f0cc44f0ca24"}}}}, {"uuid": "6413e194-03e5-48c7-88a6-50f535f3a72a", "name": "ff48c4d2-8b8a-42b7-8b13-547e96dc9bd6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1f78e963-e9df-4f71-b59b-b7020b109583", "name": "7e30d6c4-12cd-4aab-8b47-451df08c4733", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6413e194-03e5-48c7-88a6-50f535f3a72a"}}}]}, {"uuid": "e95cd4c6-356c-4db2-be42-22421b873317", "name": "load_p1rlv13707_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "286623b3-af08-4a60-896a-1f5b85fe04a5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1f78e963-e9df-4f71-b59b-b7020b109583"}}}}, {"uuid": "3366db9e-3cf3-4151-8361-83b441a1f30e", "name": "22f79fb6-2b63-4702-ab85-effb7f238529_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a0851e07-4737-49ff-84ad-daa6bc98b911", "name": "694b01b0-174c-47ff-8dd6-2ba5e1fe9d3d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3366db9e-3cf3-4151-8361-83b441a1f30e"}}}]}, {"uuid": "56d76667-0cdd-48ef-a18b-ed51d5d65d1e", "name": "load_p1rlv13707_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "286623b3-af08-4a60-896a-1f5b85fe04a5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a0851e07-4737-49ff-84ad-daa6bc98b911"}}}}, {"uuid": "75952726-7480-4eb3-8fca-e410a5609a32", "name": "1171d848-94aa-4d3f-85e2-f6b2a083abf4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "66c585a7-9929-4d9e-b2c0-4038ef131727", "name": "97b55cae-aa0a-4c34-987e-efdb2ef1e497", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "75952726-7480-4eb3-8fca-e410a5609a32"}}}]}, {"uuid": "49afa33d-2db8-4c25-baf0-db76d22a5b78", "name": "load_p1rlv13708_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a230534-6927-4af8-ba54-6ab4c9c32d21"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "66c585a7-9929-4d9e-b2c0-4038ef131727"}}}}, {"uuid": "6f76b578-9e6c-4143-9fa1-0a9d00e81721", "name": "58d582ca-d92e-49a9-afa0-3d49ad5ddf68_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "75a5498f-0a83-4d9a-a17e-bdde0fccc40d", "name": "3842aa62-58e8-4549-b39a-ef1b378b39d4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6f76b578-9e6c-4143-9fa1-0a9d00e81721"}}}]}, {"uuid": "e17a4e5a-76ab-4e2b-9deb-0ddc2436202c", "name": "load_p1rlv13708_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a230534-6927-4af8-ba54-6ab4c9c32d21"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "75a5498f-0a83-4d9a-a17e-bdde0fccc40d"}}}}, {"uuid": "b23ca2b3-f01b-4a70-9c20-3ef8d65883bc", "name": "92063d80-548f-4737-aba3-d38c65b55fda_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "58ee1ba5-d4cd-483f-b539-6f48b5664106", "name": "620fd620-3af1-4383-9614-c5fa3611b9b6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b23ca2b3-f01b-4a70-9c20-3ef8d65883bc"}}}]}, {"uuid": "6bd8147e-4da1-41f0-ab34-81bf5be88280", "name": "load_p1rlv13711_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2bfaa34-267c-4dfd-8b6d-4ab444ac4048"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "58ee1ba5-d4cd-483f-b539-6f48b5664106"}}}}, {"uuid": "b216556a-58a2-4ff4-b485-d2e41df9d5c5", "name": "46df789e-0b71-4086-9338-f9f9abed9eea_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6508feb2-672c-4f09-bedf-352defe69273", "name": "8a7044d2-9623-4090-9535-7b77ebdfd4e1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b216556a-58a2-4ff4-b485-d2e41df9d5c5"}}}]}, {"uuid": "29ab3c31-513d-4ba8-92a0-46a0df8c64dc", "name": "load_p1rlv13711_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2bfaa34-267c-4dfd-8b6d-4ab444ac4048"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6508feb2-672c-4f09-bedf-352defe69273"}}}}, {"uuid": "6418ab48-9339-4497-855a-b597731a1243", "name": "cc53d833-c02e-462e-aaa6-5805e0b3df3b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7545306166330135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0868234997236217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "146c8f5e-86e7-4955-9415-724b425e7d92", "name": "b490587e-dcfa-48bf-bb38-9da514ff2a94", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6418ab48-9339-4497-855a-b597731a1243"}}}]}, {"uuid": "ff3b22fc-25ef-4ea2-ad20-a01769dd6228", "name": "load_p1rlv13712_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ab8bce-7c02-4c7b-962e-3fb44a3ab7a9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "146c8f5e-86e7-4955-9415-724b425e7d92"}}}}, {"uuid": "97ab516e-1b75-4db4-a02f-2a3e534364ed", "name": "edbd1e33-e791-41c6-adbf-15ff89ddf2f5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7545306166330135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0868234997236217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4f328d12-489d-4a0a-ac22-c15f688ebf38", "name": "cf4b514d-e94c-426f-ac7e-479f28cfb2ed", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "97ab516e-1b75-4db4-a02f-2a3e534364ed"}}}]}, {"uuid": "6bd90a3f-7030-4ebd-8435-2deaa7b3287c", "name": "load_p1rlv13712_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ab8bce-7c02-4c7b-962e-3fb44a3ab7a9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4f328d12-489d-4a0a-ac22-c15f688ebf38"}}}}, {"uuid": "aa2897bb-6c94-4c97-beed-05beeab0409b", "name": "7eb4941e-aab2-4b82-97d4-e5a1bea33332_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fd3fa0fb-eefc-44ed-bd10-dbc69cc69dbd", "name": "409fecca-9d80-4bfd-a225-8e9f1fa11b15", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aa2897bb-6c94-4c97-beed-05beeab0409b"}}}]}, {"uuid": "01e08a61-f12d-44e2-97f7-d9d92ef0dd55", "name": "load_p1rlv13713_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee766a99-bb6f-4d5c-8513-9d462103f6fc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fd3fa0fb-eefc-44ed-bd10-dbc69cc69dbd"}}}}, {"uuid": "72227943-9753-4764-89fd-9a52b2ff60b7", "name": "992e2843-abba-4520-b23a-1ae2deee57db_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c853f8ef-2cf1-4a41-8fb3-40148f6182d7", "name": "e07790a4-62ba-4aad-9b20-dee50a745a9d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72227943-9753-4764-89fd-9a52b2ff60b7"}}}]}, {"uuid": "d6d84b9a-453c-41d6-a1fc-e90bfc7c4af3", "name": "load_p1rlv13713_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee766a99-bb6f-4d5c-8513-9d462103f6fc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c853f8ef-2cf1-4a41-8fb3-40148f6182d7"}}}}, {"uuid": "754509b2-e93c-4cc1-ba8e-8f881a1b87e6", "name": "fcfdc003-f539-4d06-97f6-74b531454884_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9972586284721718, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5405993695804993, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8e3a8735-5c81-4955-ade7-ef788305f464", "name": "d85f1cf8-8756-4671-afc2-58fc47a83939", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "754509b2-e93c-4cc1-ba8e-8f881a1b87e6"}}}]}, {"uuid": "4618bcd0-4a49-42cb-a947-1ad974ae77c8", "name": "load_p1rlv13714_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17936036-1191-4f91-bc12-2298db7b77e3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8e3a8735-5c81-4955-ade7-ef788305f464"}}}}, {"uuid": "b47fcbac-90fa-4e88-97c5-2a030255e0c9", "name": "7d7b8d24-c368-427a-a6c5-39287240dca0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9972586284721718, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5405993695804993, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "98e26e6f-9bb9-4e70-8144-92a64d3fff47", "name": "be31ff26-26d7-4011-b6e4-9a2d9c7656d3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b47fcbac-90fa-4e88-97c5-2a030255e0c9"}}}]}, {"uuid": "6a9508d2-1734-48c3-8444-79bb54072e1b", "name": "load_p1rlv13714_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17936036-1191-4f91-bc12-2298db7b77e3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "98e26e6f-9bb9-4e70-8144-92a64d3fff47"}}}}, {"uuid": "9e151eb7-5f81-440f-974d-fe976df01299", "name": "1d91d7eb-1e63-4f9f-b435-1197599db6d1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "57633dc2-dcd6-4729-a316-4e096ed1f292", "name": "36e71770-34f7-46bb-afd0-ed2986df6ca6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9e151eb7-5f81-440f-974d-fe976df01299"}}}]}, {"uuid": "c812a679-890c-4d0f-98d9-0d1f7d45f99d", "name": "load_p1rlv13715_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a822fdb0-b531-49b0-89da-b517e5ae6e3a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "57633dc2-dcd6-4729-a316-4e096ed1f292"}}}}, {"uuid": "92649058-d744-41bd-91d4-969ee02e3557", "name": "71d0b39e-c5df-4efb-b9d0-b7bb3e2d3f60_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f2dfe100-e76c-4b08-ab10-7eafc439ced1", "name": "d7fb2e79-b36a-4da1-9450-e76fda612f21", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "92649058-d744-41bd-91d4-969ee02e3557"}}}]}, {"uuid": "5523e36f-b164-4cd1-b47f-790f9d2080f0", "name": "load_p1rlv13715_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a822fdb0-b531-49b0-89da-b517e5ae6e3a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f2dfe100-e76c-4b08-ab10-7eafc439ced1"}}}}, {"uuid": "6fcedadc-5687-4d32-801f-41ea8517173a", "name": "b9c70ccf-2ea5-4a70-8329-c5a5c75154eb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0fb544c1-e897-425d-9c92-9a04c78144f4", "name": "5b8ab658-643d-4572-9f87-1dfc56ee539d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6fcedadc-5687-4d32-801f-41ea8517173a"}}}]}, {"uuid": "9373a3d8-431a-4e5b-bc97-72b35793721a", "name": "load_p1rlv13716_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb3b4207-12ad-46e6-b4de-59149a46f8a1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0fb544c1-e897-425d-9c92-9a04c78144f4"}}}}, {"uuid": "6c990dc3-9aae-434f-be73-936224343e7d", "name": "a1327074-a0dd-4963-980d-8c1955fa3f43_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "07876a8a-aef7-4bb8-83b4-1ce723379caa", "name": "e9b74712-8026-4896-b0d9-748f9f85c33b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c990dc3-9aae-434f-be73-936224343e7d"}}}]}, {"uuid": "0d8ddad1-6cb5-490c-a4a7-08840429a56d", "name": "load_p1rlv13716_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb3b4207-12ad-46e6-b4de-59149a46f8a1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "07876a8a-aef7-4bb8-83b4-1ce723379caa"}}}}, {"uuid": "7b4d227c-71c5-44be-a753-27a2e2d3c822", "name": "d7ba2655-5d70-485e-a3e2-d7dab97b4ffb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "083c693f-7451-4a82-98a6-fd33ae600b7a", "name": "254e231c-54d2-4360-84e4-cb99d595c499", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b4d227c-71c5-44be-a753-27a2e2d3c822"}}}]}, {"uuid": "40c3c225-3dc3-4e2a-8cb6-a855fc0d6d40", "name": "load_p1rlv13717_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdbfe616-f51f-416a-94ce-6e676d300226"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "083c693f-7451-4a82-98a6-fd33ae600b7a"}}}}, {"uuid": "5fd7b8b0-61ac-48cd-ab38-7094e02b1c97", "name": "fd0f1747-45ce-40d0-b4b5-2f8db2d3681c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d98c18a0-87e8-428f-a555-1a94776ba879", "name": "db0912c1-87b2-4d95-b1f8-28ada67f3122", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5fd7b8b0-61ac-48cd-ab38-7094e02b1c97"}}}]}, {"uuid": "0015d220-ad70-47b2-b3a3-4672d57385af", "name": "load_p1rlv13717_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdbfe616-f51f-416a-94ce-6e676d300226"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d98c18a0-87e8-428f-a555-1a94776ba879"}}}}, {"uuid": "25542898-6b2c-4f16-af7d-d7b082c9a12a", "name": "385d9c16-4654-417c-b777-7aa08f6a082a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6027984746974515, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12293402966163972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4632ff26-1435-4900-8c24-064f89444d78", "name": "ae548c79-9b0f-4aec-bbd3-caf8815c145e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "25542898-6b2c-4f16-af7d-d7b082c9a12a"}}}]}, {"uuid": "e97f8a95-0a85-4426-a5d7-bf700b901a92", "name": "load_p1rlv13719_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44aa3f37-e0db-4050-b47f-ac14b7fa6534"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4632ff26-1435-4900-8c24-064f89444d78"}}}}, {"uuid": "0ead7666-1788-4c58-9475-78f07dbfb2c7", "name": "ad3f2d2e-c3ce-4ceb-b06e-a313b53c404b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6027984746974515, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12293402966163972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4f684ec0-59a6-4e94-8609-46ee2f369b86", "name": "93bf93cf-51e3-4a04-bcd7-07e3527deb4e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0ead7666-1788-4c58-9475-78f07dbfb2c7"}}}]}, {"uuid": "0c2ba3a8-52db-4453-98c3-67ef3943039d", "name": "load_p1rlv13719_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44aa3f37-e0db-4050-b47f-ac14b7fa6534"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4f684ec0-59a6-4e94-8609-46ee2f369b86"}}}}, {"uuid": "065ac14e-ad43-4f8a-83bc-458d5a376d9e", "name": "2cfb0ada-7713-4150-b59c-1764af325937_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.693271865954936, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.115673740909077, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f032b135-567f-41e1-8f02-30eeb30cae74", "name": "2cfb0ada-7713-4150-b59c-1764af325937_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.693271865954936, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.115673740909077, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f66981dc-9a7f-4d48-9c9a-d014312e2040", "name": "2cfb0ada-7713-4150-b59c-1764af325937_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.693271865954936, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.115673740909077, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8b79ad69-4cec-4070-b217-a724f6a87163", "name": "18df2ab4-f102-49e3-b6d5-46c286393f54", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "065ac14e-ad43-4f8a-83bc-458d5a376d9e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f032b135-567f-41e1-8f02-30eeb30cae74"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f66981dc-9a7f-4d48-9c9a-d014312e2040"}}}]}, {"uuid": "40539eb5-04a1-47e8-a33d-f250c4efcda6", "name": "load_p1rlv13720", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fe1a5da7-bdac-46a6-ab32-addc4f02a296"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8b79ad69-4cec-4070-b217-a724f6a87163"}}}}, {"uuid": "a4bea439-76cd-4468-a365-8b99869e18b0", "name": "ff334ece-0414-4a5d-978d-16814908ce78_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.498014754859445, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0be10e40-addc-44a0-95b8-17c2667d64b0", "name": "865d928c-09a8-4aa7-89d9-5402b1f98597", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a4bea439-76cd-4468-a365-8b99869e18b0"}}}]}, {"uuid": "4532d3a3-933d-4350-bf56-5f09d7e02f59", "name": "load_p1rlv13721_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6097c903-70fc-4635-a66c-fee2243ba545"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0be10e40-addc-44a0-95b8-17c2667d64b0"}}}}, {"uuid": "cf061642-a570-42d7-b6a1-bda4f7bf11ad", "name": "376a1a9f-7a87-4dc5-8f2b-c2e69d99aedb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.498014754859445, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2f0f3560-d5e9-45dc-8fa1-57c4492d0228", "name": "b2f84c5f-390e-4a57-b294-a258c93c856b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cf061642-a570-42d7-b6a1-bda4f7bf11ad"}}}]}, {"uuid": "e2a2af36-b6fb-44d1-9b8d-8a541a55cbc9", "name": "load_p1rlv13721_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6097c903-70fc-4635-a66c-fee2243ba545"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2f0f3560-d5e9-45dc-8fa1-57c4492d0228"}}}}, {"uuid": "cbaebd38-060c-47f8-a31d-82317d5498d4", "name": "8400bf58-7f39-43b7-8782-b26400ae2afa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0772156037646567, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.01984596164170695, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "adb63022-7bff-420c-9630-a71369c1173d", "name": "93f5ad57-9582-470d-b478-7cf205431bde", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cbaebd38-060c-47f8-a31d-82317d5498d4"}}}]}, {"uuid": "5913b235-7f23-44d3-9bed-4855db1ffb03", "name": "load_p1rlv13723_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0f1846b-2515-48ef-9241-0276932f8e75"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "adb63022-7bff-420c-9630-a71369c1173d"}}}}, {"uuid": "63a5c690-9991-4d51-b11e-65fa0936739c", "name": "e646f638-eead-4a67-a015-aabf77b9dfdd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0772156037646567, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.01984596164170695, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a4afb26a-6c9f-4511-b59f-42dc4d6fc4b6", "name": "fbda14f5-a977-4076-bac2-a87ecd3c5a6b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "63a5c690-9991-4d51-b11e-65fa0936739c"}}}]}, {"uuid": "4978d1b9-2594-4bf0-af8d-9600ad7d7685", "name": "load_p1rlv13723_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0f1846b-2515-48ef-9241-0276932f8e75"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a4afb26a-6c9f-4511-b59f-42dc4d6fc4b6"}}}}, {"uuid": "3b053fe4-7517-4e8b-a5db-7c0200c5301f", "name": "09d2550e-5249-4897-86b2-15f06064b6df_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6277722044378486, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6969686665668667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7370b0bd-80cd-433b-9192-bc43c5e1a7be", "name": "7c3ad141-20bd-4f8a-ae12-33ad20556a42", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3b053fe4-7517-4e8b-a5db-7c0200c5301f"}}}]}, {"uuid": "a45714a0-7b14-4206-955f-80f8c450db3d", "name": "load_p1rlv13724_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "457c6c9d-5020-4cf3-9c1e-c36012a619d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7370b0bd-80cd-433b-9192-bc43c5e1a7be"}}}}, {"uuid": "58a76492-a584-4280-918a-07b715d387df", "name": "7b59b86e-a70a-42ac-a0ac-c35549727ff6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6277722044378486, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6969686665668667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a143659c-ad8d-4069-a8e5-cb7f495a2ab8", "name": "ddac1d04-e4a4-4508-b483-e46fc85dcad2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58a76492-a584-4280-918a-07b715d387df"}}}]}, {"uuid": "2f81c172-7861-4ac1-8635-9c7b7be1eea0", "name": "load_p1rlv13724_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "457c6c9d-5020-4cf3-9c1e-c36012a619d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a143659c-ad8d-4069-a8e5-cb7f495a2ab8"}}}}, {"uuid": "4f7e210b-8657-4907-afb0-2fdeb6ad39f8", "name": "7f12debb-47ea-4b10-814d-ebf7df7088b1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4699462180170992, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3815978523472859, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f722faea-19a7-4445-a5ba-aabe9951ae25", "name": "91821276-4178-4e96-9357-2242c8f18dcf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4f7e210b-8657-4907-afb0-2fdeb6ad39f8"}}}]}, {"uuid": "b3032777-00a4-4e8d-b124-8e1154386c77", "name": "load_p1rlv13725_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e290046b-c936-4f51-b4ef-632bf572ab7f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f722faea-19a7-4445-a5ba-aabe9951ae25"}}}}, {"uuid": "0e7e24f0-18d9-4954-a6ec-adedf0f98db4", "name": "fadc48c3-d531-4be2-b3d2-977404485f0c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4699462180170992, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3815978523472859, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "16112990-2183-48fd-b59c-e1c31239ab37", "name": "01c5727b-1947-47bd-aa23-129b2373e7f0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0e7e24f0-18d9-4954-a6ec-adedf0f98db4"}}}]}, {"uuid": "ecf2d690-b53e-409e-bd12-3fe278a4a408", "name": "load_p1rlv13725_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e290046b-c936-4f51-b4ef-632bf572ab7f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "16112990-2183-48fd-b59c-e1c31239ab37"}}}}, {"uuid": "ea59716e-ff02-4fe0-96c9-98334af45343", "name": "ccb1f4b6-7666-40ab-805b-387e4127deff_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.559543722017981, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7101531402521069, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "024d4b5b-caec-4dd8-9523-0dd3f77ec616", "name": "77ee0385-e9d9-4ce9-9814-3f1f72612aa2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ea59716e-ff02-4fe0-96c9-98334af45343"}}}]}, {"uuid": "a1074246-39b6-4a84-9bb3-bab5de04efcb", "name": "load_p1rlv13726_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "642597e6-fe60-442f-b356-2be6f21677b2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "024d4b5b-caec-4dd8-9523-0dd3f77ec616"}}}}, {"uuid": "8097c180-7252-4a8f-a0c2-31caa4e0bcd5", "name": "d5075581-9fed-4669-a63b-22e5f594bb9f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.559543722017981, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7101531402521069, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1612c2b3-272a-438e-a8a2-9c070b656f67", "name": "f41c0c3f-0dbb-445c-89f4-14d751b99d4c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8097c180-7252-4a8f-a0c2-31caa4e0bcd5"}}}]}, {"uuid": "772e3056-1184-4bbd-8456-11bb88f849a8", "name": "load_p1rlv13726_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "642597e6-fe60-442f-b356-2be6f21677b2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1612c2b3-272a-438e-a8a2-9c070b656f67"}}}}, {"uuid": "570b274f-388c-4c5e-8765-e1f43c2d99c8", "name": "a73059bb-e437-48a1-a2e4-b6ea38a2ec24_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.70898089652498, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7830599711618245, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a3e04680-3dfe-4696-aa2f-3d698a557628", "name": "914c2206-d850-42aa-9034-897718169bba", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "570b274f-388c-4c5e-8765-e1f43c2d99c8"}}}]}, {"uuid": "32c8420d-bc08-4ddf-8ad2-5c1a91750b99", "name": "load_p1rlv13727_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36019623-eb62-412c-a591-41494980c9b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a3e04680-3dfe-4696-aa2f-3d698a557628"}}}}, {"uuid": "045e5b4c-a5d1-493d-b89f-abaec81c479b", "name": "595944c9-4275-4c6a-8559-118d0090546e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.70898089652498, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7830599711618245, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1f4e5df6-c5db-4a5d-8c90-987416e54d98", "name": "923d034c-aa7d-4a9f-b117-fc14c9d85510", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "045e5b4c-a5d1-493d-b89f-abaec81c479b"}}}]}, {"uuid": "23ec0f8d-ad28-4acf-833c-91ed0581460c", "name": "load_p1rlv13727_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36019623-eb62-412c-a591-41494980c9b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1f4e5df6-c5db-4a5d-8c90-987416e54d98"}}}}, {"uuid": "2f09022f-95e8-4f03-94eb-632b3deb5bb2", "name": "5e42c9ef-4052-4d9d-96a7-e6436c2a4815_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 12.611907582113087, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.885290064059574, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c9f56e64-a595-48aa-a382-bcb537d235f4", "name": "e80b2ee4-a8a5-4d22-b5bb-257be53e5acc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2f09022f-95e8-4f03-94eb-632b3deb5bb2"}}}]}, {"uuid": "9a416140-7041-43b6-b2bd-25ee741cb466", "name": "load_p1rlv13728_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9657a993-0005-4ffc-8c9f-18e80a491070"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c9f56e64-a595-48aa-a382-bcb537d235f4"}}}}, {"uuid": "6835f5d8-a666-42d4-9f3f-4c86fe3ed12a", "name": "cac9a18c-75a4-4d56-a1cd-2880d62c8486_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 12.611907582113087, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.885290064059574, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "053915d4-d4ac-42e4-b303-1e25bbde93b1", "name": "2f2112f0-e24c-4a82-9929-c3bc07c98c09", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6835f5d8-a666-42d4-9f3f-4c86fe3ed12a"}}}]}, {"uuid": "92fc514e-a83d-4451-935b-c49f7cee00a2", "name": "load_p1rlv13728_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9657a993-0005-4ffc-8c9f-18e80a491070"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "053915d4-d4ac-42e4-b303-1e25bbde93b1"}}}}, {"uuid": "0b48ddbd-a8b0-489e-9867-ef8439109a26", "name": "9297ef60-e9ea-4582-843d-ca70d318c44d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.028781788264419, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6709073147144231, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "12d5a0f8-56fc-40b7-8f45-1bf67557aee7", "name": "a105314f-aa53-4476-942b-c5766d404511", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0b48ddbd-a8b0-489e-9867-ef8439109a26"}}}]}, {"uuid": "e2fe9658-1741-473a-bd57-9eb0b2f3485f", "name": "load_p1rlv13784_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01a18948-75cf-4caf-951f-17a9c8d1f6bc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "12d5a0f8-56fc-40b7-8f45-1bf67557aee7"}}}}, {"uuid": "7306ded9-8b69-4dbe-86d5-7ea4fb33190c", "name": "086b660b-e051-4ebe-8a74-ed7483f89e33_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.028781788264419, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6709073147144231, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e85fd6fb-5334-49b7-8a84-405c8bb4daa7", "name": "9494e3dd-556a-41ff-a9ef-3612c4ae268e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7306ded9-8b69-4dbe-86d5-7ea4fb33190c"}}}]}, {"uuid": "d4e8b427-9fc7-4230-85f4-304d66ccd6c9", "name": "load_p1rlv13784_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01a18948-75cf-4caf-951f-17a9c8d1f6bc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e85fd6fb-5334-49b7-8a84-405c8bb4daa7"}}}}, {"uuid": "ae3335b0-295f-42bf-9b0d-e8c237fc40ce", "name": "4060d010-a34b-4f61-8baf-4b0fe8cf82ab_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7293ed3d-db31-4b0f-84ed-e1072d29fbec", "name": "fb539322-9819-40d4-b232-831a1dde2861", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ae3335b0-295f-42bf-9b0d-e8c237fc40ce"}}}]}, {"uuid": "e8de7c85-8abc-4098-92f1-6c262259c9af", "name": "load_p1rlv13792_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc5fcb56-435a-4a0d-b442-7489a98ad1cd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7293ed3d-db31-4b0f-84ed-e1072d29fbec"}}}}, {"uuid": "d2033207-79e4-41b4-872b-3ed0e60c5126", "name": "d4f5c4fa-ad8a-4e7b-a6ca-6797dbe1c260_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "be6d7968-c8a6-4621-aded-3efc1b5efcdf", "name": "042507ee-5a14-4ec3-9d92-871b2b26fa62", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d2033207-79e4-41b4-872b-3ed0e60c5126"}}}]}, {"uuid": "474c83a9-55f4-443c-b6fd-1267c438ab86", "name": "load_p1rlv13792_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc5fcb56-435a-4a0d-b442-7489a98ad1cd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "be6d7968-c8a6-4621-aded-3efc1b5efcdf"}}}}, {"uuid": "5b948bc6-9a04-4795-bfa9-01eb6d87861c", "name": "f74d6c3d-0371-4640-ab31-1c93d9435f40_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1648375907215343, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4430202395847888, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3757cab6-2ee7-4a95-9d71-ee3846d99760", "name": "f29f50b2-b0c2-4aac-9fb3-11b6e10eacf8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b948bc6-9a04-4795-bfa9-01eb6d87861c"}}}]}, {"uuid": "729053e2-f61f-4ddf-a62e-79e8d78caee2", "name": "load_p1rlv13794_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9725b6c-5bac-456a-bb6a-ce16a5e6b1a5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3757cab6-2ee7-4a95-9d71-ee3846d99760"}}}}, {"uuid": "22f8b219-1ab3-4775-8009-4d45ab313fe2", "name": "cf79beb3-0468-457c-93c0-5927e700c10b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1648375907215343, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4430202395847888, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e19d4fa9-8881-432a-96f0-f4c01ce935d6", "name": "3a35aef1-8f52-4b9f-8de2-b4a9e23b2983", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "22f8b219-1ab3-4775-8009-4d45ab313fe2"}}}]}, {"uuid": "1a73fa78-912f-42a0-b075-c5e4f8e75dab", "name": "load_p1rlv13794_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9725b6c-5bac-456a-bb6a-ce16a5e6b1a5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e19d4fa9-8881-432a-96f0-f4c01ce935d6"}}}}, {"uuid": "2b094398-1b00-4649-8d7d-ec234c2cddf5", "name": "62c30933-adac-4a05-b9f2-bee562077aa1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9518333270985427, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3340330193202704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3f11dbf6-443f-4bdf-aee0-650b675953bc", "name": "9a000fbc-b2e7-4a6c-9203-504fefd68405", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2b094398-1b00-4649-8d7d-ec234c2cddf5"}}}]}, {"uuid": "88688a62-05b0-48d5-a2fc-b720e3b3611e", "name": "load_p1rlv13797_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65052833-aec9-4363-a0cf-4d70fa9bb0ce"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3f11dbf6-443f-4bdf-aee0-650b675953bc"}}}}, {"uuid": "b9ce6736-7aa9-4e91-a962-bf314292f154", "name": "85fdcf94-c44a-429f-aab8-c3604ee2a35e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9518333270985427, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3340330193202704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1e15fbf3-d3eb-46e6-9043-f08cba648a41", "name": "72e7bea1-9154-4c38-b781-660b6f0b1f12", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b9ce6736-7aa9-4e91-a962-bf314292f154"}}}]}, {"uuid": "b7f8b025-5f44-4628-aebc-fb733bf3a827", "name": "load_p1rlv13797_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65052833-aec9-4363-a0cf-4d70fa9bb0ce"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1e15fbf3-d3eb-46e6-9043-f08cba648a41"}}}}, {"uuid": "d008dff8-0eca-43b2-a489-dddf1259f8b1", "name": "8263be69-f301-49f1-ad74-aff7cea45575_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.661093206685493, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9884186563142763, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2c148610-e18e-42ff-86f5-86f7e7d46e1c", "name": "33001303-0875-48b6-9db5-97731631a2ce", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d008dff8-0eca-43b2-a489-dddf1259f8b1"}}}]}, {"uuid": "1c9bbfba-9960-4261-8309-cf060c9695a0", "name": "load_p1rlv13805_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83d60921-a1f2-4b9c-9709-d2be59b82db5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2c148610-e18e-42ff-86f5-86f7e7d46e1c"}}}}, {"uuid": "d99dc7bf-d409-4931-8fca-5f94a2b89c2d", "name": "f1db1921-7c69-4ceb-a463-94b278426670_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.661093206685493, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9884186563142763, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "46ebd613-17d9-427f-9c79-d5e5beeb5dec", "name": "98235c32-1c83-4c03-8da0-0d2c93bd8a2a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d99dc7bf-d409-4931-8fca-5f94a2b89c2d"}}}]}, {"uuid": "f1119480-14dc-4bfe-bc02-83f47b1c6f79", "name": "load_p1rlv13805_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83d60921-a1f2-4b9c-9709-d2be59b82db5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "46ebd613-17d9-427f-9c79-d5e5beeb5dec"}}}}, {"uuid": "f99e86d1-f09c-4c75-a62c-86a281b8e3de", "name": "b85266ba-b80c-4fd8-a566-d2195631ff4e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4464370236076721, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16599396793014964, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bf53e031-d4a6-48aa-a830-5c127fd126cb", "name": "c7f377ac-0f6f-45f4-94d6-62ce97af7fd5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f99e86d1-f09c-4c75-a62c-86a281b8e3de"}}}]}, {"uuid": "b310fa6b-3561-4f44-8c02-3fe5845177b1", "name": "load_p1rlv13811_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aef2ef8-706c-4316-be01-0707ddf0ac7c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bf53e031-d4a6-48aa-a830-5c127fd126cb"}}}}, {"uuid": "54c9112e-beac-4376-98fb-29a9fcd58369", "name": "497ad5bf-510b-454f-8e94-b0e25fc99de0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4464370236076721, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16599396793014964, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3f6629e0-d2f9-4154-9736-947e7689538b", "name": "72b40a6b-934a-44df-974f-5f432dfb5ea5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "54c9112e-beac-4376-98fb-29a9fcd58369"}}}]}, {"uuid": "4ae17924-c7b0-46b0-96b7-eb50d517392e", "name": "load_p1rlv13811_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aef2ef8-706c-4316-be01-0707ddf0ac7c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3f6629e0-d2f9-4154-9736-947e7689538b"}}}}, {"uuid": "bdab4977-8247-45c9-b12d-2c32d8ab1531", "name": "dd9d5f22-24e3-4e93-822d-9f8855946932_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4868228207229564, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16976956391895093, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ec7818b8-f415-4595-9286-203cafa19f52", "name": "3406079d-61de-4f6a-98e0-94b3c6186342", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bdab4977-8247-45c9-b12d-2c32d8ab1531"}}}]}, {"uuid": "d85187ab-becb-484f-9857-aa2f29732078", "name": "load_p1rlv13812_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ffd737b-a273-4a6c-91c6-351b5719f658"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ec7818b8-f415-4595-9286-203cafa19f52"}}}}, {"uuid": "bedef87c-cbc5-4343-8474-fdc4146c18ef", "name": "ccd49114-65bb-46d0-b5bf-20327daf6b3a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4868228207229564, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16976956391895093, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a33faf8d-ee17-4d08-ae59-f31c6d3430b7", "name": "e985d90e-4301-48f8-ac94-7932b0618b99", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bedef87c-cbc5-4343-8474-fdc4146c18ef"}}}]}, {"uuid": "2f70ad94-00e8-4947-9e08-561f3609687b", "name": "load_p1rlv13812_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ffd737b-a273-4a6c-91c6-351b5719f658"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a33faf8d-ee17-4d08-ae59-f31c6d3430b7"}}}}, {"uuid": "4ec6c000-17d6-4c00-bb2f-69d9421922fb", "name": "ed2a0538-3156-40d4-ba8a-b0061f7ae68a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2596055778412756, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4460523908595607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b3f55c19-e53c-43aa-b18a-7806debc8e10", "name": "fcfe9690-2ba1-4777-8755-0e648a44743e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4ec6c000-17d6-4c00-bb2f-69d9421922fb"}}}]}, {"uuid": "23a8dfde-cdf0-451c-b9bc-aee846edd2e6", "name": "load_p1rlv14434_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06135bd7-6a77-4f04-a439-4ce8c245447d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b3f55c19-e53c-43aa-b18a-7806debc8e10"}}}}, {"uuid": "50ec0c20-f152-4fd9-bdc8-ee03a07ede22", "name": "32214626-4faa-45ff-abe3-5416beeae5df_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2596055778412756, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4460523908595607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "37ced1c4-aaba-4f1f-85f2-327c2445e6f8", "name": "5f0e1323-82cf-4eed-9712-6fd2cc97e929", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "50ec0c20-f152-4fd9-bdc8-ee03a07ede22"}}}]}, {"uuid": "0a8f122e-7a9a-482f-a8c6-baeea7a29ca9", "name": "load_p1rlv14434_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06135bd7-6a77-4f04-a439-4ce8c245447d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "37ced1c4-aaba-4f1f-85f2-327c2445e6f8"}}}}, {"uuid": "2d0e31de-a0df-46f1-af90-1b937b60ca43", "name": "7cbf61d5-0ee4-47ce-9378-2b7d7c9764b9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.904546554088597, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7711735109904765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1aa2825e-0efd-4844-a72b-6df0455193e5", "name": "3c187500-8a3f-4463-8769-bf684e0c7eaf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2d0e31de-a0df-46f1-af90-1b937b60ca43"}}}]}, {"uuid": "081fe3c5-fef8-4a22-bc81-65e9d2728088", "name": "load_p1rlv14435_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d07f5065-df41-484d-8e8a-80b2ff4e0e9b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1aa2825e-0efd-4844-a72b-6df0455193e5"}}}}, {"uuid": "471a413f-2eaa-4197-bece-c67b603b162a", "name": "8ee074cf-d8bd-40db-acdd-38204fd9aa91_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.904546554088597, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7711735109904765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b734a13b-49ba-4216-981a-a1c26b8442c2", "name": "17d0d18e-bb91-411a-b7f1-b8ea738d3cfb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "471a413f-2eaa-4197-bece-c67b603b162a"}}}]}, {"uuid": "99d1a71f-f989-47fc-9f83-39b676d187bd", "name": "load_p1rlv14435_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d07f5065-df41-484d-8e8a-80b2ff4e0e9b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b734a13b-49ba-4216-981a-a1c26b8442c2"}}}}, {"uuid": "5e9875d5-2bd2-4a80-9fb0-5aa1837a67ca", "name": "f7f82c80-17c7-4f51-b255-1e93d8e027cc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.756100999166533, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1794980420068588, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "80d5b990-bd78-4ae5-a3b9-1d77a3da445b", "name": "7445fd14-5983-48a7-87ca-6e5659032878", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5e9875d5-2bd2-4a80-9fb0-5aa1837a67ca"}}}]}, {"uuid": "b9f752a7-b6e4-405d-add0-812f294bcf81", "name": "load_p1rlv14436_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad66e41a-88ab-443e-b10e-9e7b5b899119"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "80d5b990-bd78-4ae5-a3b9-1d77a3da445b"}}}}, {"uuid": "aff84010-8b8c-4a7f-9d4c-2c43694a952c", "name": "dbbbf139-0f95-48f5-acaa-086e1c44c25d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.756100999166533, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1794980420068588, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5cf4d181-0b70-4419-be75-5d3190cb1735", "name": "bef3bd59-9ee9-45c6-abb9-3fb7e9de4705", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aff84010-8b8c-4a7f-9d4c-2c43694a952c"}}}]}, {"uuid": "5564228d-f485-4130-86a3-04573a3e29b9", "name": "load_p1rlv14436_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad66e41a-88ab-443e-b10e-9e7b5b899119"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5cf4d181-0b70-4419-be75-5d3190cb1735"}}}}, {"uuid": "0dbe7793-0d47-4fe5-b038-3b999b242fae", "name": "4750cf80-9c97-4274-a712-b73798096b15_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7653657521185364, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4426471780914222, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3b82e80a-6324-40d2-b374-9db33fa5ef57", "name": "594897a8-f6aa-4272-b22b-26448d576c26", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0dbe7793-0d47-4fe5-b038-3b999b242fae"}}}]}, {"uuid": "82aca4f2-6c5b-4bc0-aae2-b5a49a64d263", "name": "load_p1rlv14828_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9efa4c9-9832-4aa8-bf44-be0fe1e80cd5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3b82e80a-6324-40d2-b374-9db33fa5ef57"}}}}, {"uuid": "5903d2f9-91a7-435c-a8cb-1f11fb6a26a6", "name": "87761cbc-dbf1-499a-a572-16632761c2ef_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7653657521185364, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4426471780914222, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "68492e2a-6570-4bce-a33d-57f001e3234d", "name": "a6054e8b-ee23-467a-bcd2-bc1425d9c6de", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5903d2f9-91a7-435c-a8cb-1f11fb6a26a6"}}}]}, {"uuid": "4c2198f5-7b12-499e-8ed8-99d3054d67db", "name": "load_p1rlv14828_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9efa4c9-9832-4aa8-bf44-be0fe1e80cd5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "68492e2a-6570-4bce-a33d-57f001e3234d"}}}}, {"uuid": "2f9dd3b5-b8b8-4e57-b14a-7648ea564701", "name": "045a91b1-8843-4bc1-8108-7545409dc696_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1976836424562762, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1051220183522544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c44694fe-ec4b-4975-90d4-b20dfc47bfda", "name": "27abf23f-031c-4ff8-a27f-946c42b90b7d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2f9dd3b5-b8b8-4e57-b14a-7648ea564701"}}}]}, {"uuid": "62705e48-23c3-40f1-ba30-985371f037f0", "name": "load_p1rlv14908_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d73b0321-e181-4ecd-b431-9aa6985d56d0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c44694fe-ec4b-4975-90d4-b20dfc47bfda"}}}}, {"uuid": "13973059-1455-492f-aa8d-4f0949f37171", "name": "de2f93d0-3b7f-47ef-847c-60e38ab38cf5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1976836424562762, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1051220183522544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c586f4c7-ef88-4352-8862-0775454adae6", "name": "41def184-fcb6-41ff-a21f-b6c96c5b1e91", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "13973059-1455-492f-aa8d-4f0949f37171"}}}]}, {"uuid": "5fb5c5f4-eb51-4b8f-964d-bda964502433", "name": "load_p1rlv14908_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d73b0321-e181-4ecd-b431-9aa6985d56d0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c586f4c7-ef88-4352-8862-0775454adae6"}}}}, {"uuid": "c451fcb3-16fc-4ab4-b742-9685f3c20147", "name": "046c2e5c-9bcd-49b7-985d-ff87924957d4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9dc3c26b-791e-418e-8438-ab88c139d380", "name": "793240ef-b02c-4623-b140-29599685560b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c451fcb3-16fc-4ab4-b742-9685f3c20147"}}}]}, {"uuid": "d353f84e-cf15-45cb-8dfe-3c455036fa82", "name": "load_p1rlv14952_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3c39b0c-9c92-4934-876f-ee5f542f95cc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9dc3c26b-791e-418e-8438-ab88c139d380"}}}}, {"uuid": "ada1f288-eb32-40fa-a93c-b178dc471a25", "name": "e6624cbc-01a1-4d75-a74d-6f51903b1cb6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7978430e-b47f-471e-abf3-c557209eb1af", "name": "71ca7f34-1f1f-4d74-b942-b183995d7a2b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ada1f288-eb32-40fa-a93c-b178dc471a25"}}}]}, {"uuid": "9c5c9761-f21a-4ed3-bbc7-c95e9ac88e6e", "name": "load_p1rlv14952_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3c39b0c-9c92-4934-876f-ee5f542f95cc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7978430e-b47f-471e-abf3-c557209eb1af"}}}}, {"uuid": "55ab0755-f6d0-4afe-a977-e9fe416d48e2", "name": "9a9b70aa-72c9-48c4-a97a-893f6c40a381_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.374506393438246, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.694445400364831, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0edb6602-5e0c-49db-af53-afaac6863971", "name": "81b0d1c0-35ef-4ae8-a27d-231ab99ead98", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "55ab0755-f6d0-4afe-a977-e9fe416d48e2"}}}]}, {"uuid": "ba37f6a9-d2e1-45fd-93f2-5592c7c07386", "name": "load_p1rlv14954_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9e128f5-eb18-44df-8ec4-35bd049ef630"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0edb6602-5e0c-49db-af53-afaac6863971"}}}}, {"uuid": "1b602400-59f5-47f9-9bde-fdaac8e37572", "name": "94af954a-5059-44d9-af06-f44215920afb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.374506393438246, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.694445400364831, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7b432e8c-65cf-4990-a136-2379e96e5e79", "name": "1ddba20c-906e-43c1-99f8-eb531288b44e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1b602400-59f5-47f9-9bde-fdaac8e37572"}}}]}, {"uuid": "3acda848-9982-497f-bebc-bed963f86579", "name": "load_p1rlv14954_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9e128f5-eb18-44df-8ec4-35bd049ef630"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7b432e8c-65cf-4990-a136-2379e96e5e79"}}}}, {"uuid": "faaf63ea-d3bd-4351-83df-e6a9432ebd55", "name": "6af9cafb-9b46-471d-a620-d791cde8077a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.749950841708346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2019248045205122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fc221dbf-f8e8-4ad9-bbf9-d8ae1e8a99f3", "name": "77966535-8c36-425a-9913-dcd3e54c7a90", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "faaf63ea-d3bd-4351-83df-e6a9432ebd55"}}}]}, {"uuid": "02ceef6f-f4f0-4a1d-bf34-d2b1cae4ccc5", "name": "load_p1rlv14974_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "884ff47e-8e20-4ae8-97bd-287d0ca9dc1b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fc221dbf-f8e8-4ad9-bbf9-d8ae1e8a99f3"}}}}, {"uuid": "a47ccb41-9101-4862-9919-266c22934ac6", "name": "41281d89-de87-494a-b10d-2065930fe40d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.749950841708346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2019248045205122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a7de7a39-b75c-496a-aa48-cac2e1e4e315", "name": "af67500e-fe6b-4ac5-b512-ab34bdc795d8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a47ccb41-9101-4862-9919-266c22934ac6"}}}]}, {"uuid": "935fef31-6064-44c6-b4e7-1d67031960e8", "name": "load_p1rlv14974_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "884ff47e-8e20-4ae8-97bd-287d0ca9dc1b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a7de7a39-b75c-496a-aa48-cac2e1e4e315"}}}}, {"uuid": "1c8a1050-9e99-4748-a965-b48dc79e1a7b", "name": "208ed43a-7564-4026-8572-a2af145b4198_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.446531565278448, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9314679219387375, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3d6ac767-6b08-40a3-afe2-fd754bdb6e44", "name": "6c859f0b-a1fc-46b5-9113-1bd2784ae024", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1c8a1050-9e99-4748-a965-b48dc79e1a7b"}}}]}, {"uuid": "e1739cc0-2f69-4dd4-8772-857e3b95a2da", "name": "load_p1rlv14992_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4f8b1bc-83c3-4819-9d98-9491df98d494"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3d6ac767-6b08-40a3-afe2-fd754bdb6e44"}}}}, {"uuid": "fa59870f-88a2-4890-9295-c01066faa555", "name": "b35a08ad-9702-4e0a-8707-72a6299a3d62_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.446531565278448, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9314679219387375, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a0f7b08-80b8-4e40-9c1f-5305c35720f2", "name": "f299f9be-c5b0-42ab-b5f5-5f804bd03d2f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fa59870f-88a2-4890-9295-c01066faa555"}}}]}, {"uuid": "9419b869-2e79-4f11-9b36-8a2d43f5ca86", "name": "load_p1rlv14992_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4f8b1bc-83c3-4819-9d98-9491df98d494"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0a0f7b08-80b8-4e40-9c1f-5305c35720f2"}}}}, {"uuid": "2d368127-8205-4442-9a21-37ee30d3f334", "name": "cab7b5f5-254d-4612-b29a-ee256010e346_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.667455481738122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8122169683202977, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f1435521-c53a-4628-ba0c-29fab58ef34f", "name": "424231c3-871e-42ab-b340-3810cde2a19c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2d368127-8205-4442-9a21-37ee30d3f334"}}}]}, {"uuid": "e519484b-3290-497d-8b32-be3a202acc1d", "name": "load_p1rlv15007_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc29de5b-3a3f-40c0-bde4-9a57f5f62b5c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f1435521-c53a-4628-ba0c-29fab58ef34f"}}}}, {"uuid": "af7b4c86-76f9-4a08-808b-3faf1fda48be", "name": "3dfb5887-53cb-4e9d-862f-0c648e2d0aae_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.667455481738122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8122169683202977, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "be2aac07-1e00-474e-a6c3-5451a234ac7d", "name": "633c8a6c-8ee7-43de-8e99-a75ffe5c6223", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "af7b4c86-76f9-4a08-808b-3faf1fda48be"}}}]}, {"uuid": "333f0478-984e-4add-baac-b5bded1c612d", "name": "load_p1rlv15007_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc29de5b-3a3f-40c0-bde4-9a57f5f62b5c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "be2aac07-1e00-474e-a6c3-5451a234ac7d"}}}}, {"uuid": "3b4a6592-f755-44ef-8cf2-2744c004d806", "name": "7df558ba-4f9b-4d05-802a-84fe6da2eba6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7847716543397305, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8567239737527961, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c10a1df-1289-4c5d-95cc-6ae363879d1b", "name": "f699cd67-9d6c-42de-af3e-3b5b25db4abf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3b4a6592-f755-44ef-8cf2-2744c004d806"}}}]}, {"uuid": "e796f84b-ec7a-4323-9053-423934ab8911", "name": "load_p1rlv15008_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19231152-1fd1-4e07-a5d9-603c765b2cae"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c10a1df-1289-4c5d-95cc-6ae363879d1b"}}}}, {"uuid": "155d9294-2026-4595-a10f-5d1d3370d942", "name": "d1ff1274-c897-4045-a6ab-1bc942556d49_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7847716543397305, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8567239737527961, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4cf1c416-9a98-4133-abfb-d14595d37519", "name": "58be0c17-d02f-4a51-81ea-eb67be621b58", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "155d9294-2026-4595-a10f-5d1d3370d942"}}}]}, {"uuid": "e4f20f75-2bf9-44b6-9665-9dcfd0831802", "name": "load_p1rlv15008_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19231152-1fd1-4e07-a5d9-603c765b2cae"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4cf1c416-9a98-4133-abfb-d14595d37519"}}}}, {"uuid": "88061b2d-03dd-4bef-b2aa-c5113d39db92", "name": "3d8d4048-7d53-47a2-9ff8-b98a7c5a734d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6848010607962993, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6615616037111118, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "33b2a2ec-137a-40da-bab7-0d9db8e29dba", "name": "2c8cc345-ec14-454c-a3df-7999de4b373e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "88061b2d-03dd-4bef-b2aa-c5113d39db92"}}}]}, {"uuid": "ef3cd349-73a6-4848-b20b-cdd1218fcd31", "name": "load_p1rlv15027_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07e3b847-cc9a-4f84-bc00-cb4396b6dea0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "33b2a2ec-137a-40da-bab7-0d9db8e29dba"}}}}, {"uuid": "0bb0048a-e1a5-4541-9c5b-7b1754279a93", "name": "36d9565b-932f-4eac-8928-c87b2db194cc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6848010607962993, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6615616037111118, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4010dd0f-be87-4210-ab11-20b47a6824f2", "name": "5a251cb6-cfea-45a4-a2ab-a30edaea99f1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0bb0048a-e1a5-4541-9c5b-7b1754279a93"}}}]}, {"uuid": "14061709-05d6-4809-a0fb-8de5dbb878c7", "name": "load_p1rlv15027_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07e3b847-cc9a-4f84-bc00-cb4396b6dea0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4010dd0f-be87-4210-ab11-20b47a6824f2"}}}}, {"uuid": "aa3ecebd-b7f6-453c-b107-f9de938836e8", "name": "18d1cbb6-315b-4ac8-8058-357d964badc0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.297417532176794, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2780703813036578, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "065b9b89-c7a5-42c6-a9ad-b1f750c56c53", "name": "23ed7327-4f19-48a3-b8ec-a1246c3101a3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aa3ecebd-b7f6-453c-b107-f9de938836e8"}}}]}, {"uuid": "abf89700-c23c-4f1f-9986-f9363dd66505", "name": "load_p1rlv15045_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "baccbdab-efc0-487d-b00d-38d3d4be57b4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "065b9b89-c7a5-42c6-a9ad-b1f750c56c53"}}}}, {"uuid": "e82a813c-40b1-4474-94ad-105922c9197a", "name": "be588434-76bf-42da-8db0-63712217a3ad_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.297417532176794, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2780703813036578, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6fdb5567-a8c7-45aa-9049-70c86ad648bf", "name": "892b9695-55fc-43ed-a900-4ad2df7299a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e82a813c-40b1-4474-94ad-105922c9197a"}}}]}, {"uuid": "5e9e9d33-d84f-422b-aec3-bd7049a99b07", "name": "load_p1rlv15045_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "baccbdab-efc0-487d-b00d-38d3d4be57b4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6fdb5567-a8c7-45aa-9049-70c86ad648bf"}}}}, {"uuid": "54f59e7b-dbde-4448-9adf-2c3b2b205aee", "name": "0d9b2913-0b05-4723-a677-45647949f9dd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3054635933061174, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.028189505661142127, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "35859e7f-0203-421f-b7e1-95a5d1f8bdad", "name": "5aabebba-312c-4cd1-9dcb-ab9c9f89edef", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "54f59e7b-dbde-4448-9adf-2c3b2b205aee"}}}]}, {"uuid": "7b61f36b-0fd8-4db1-8d5e-3bd2e69ded78", "name": "load_p1rlv15046_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2182c9fd-fd3d-4cb1-b525-192480823e2f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "35859e7f-0203-421f-b7e1-95a5d1f8bdad"}}}}, {"uuid": "d5da2654-9c5d-4151-b380-9a54ef5dff84", "name": "76b214c4-32dd-43ae-ae73-5a04d373e4c6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3054635933061174, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.028189505661142127, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fbcde39a-5be9-4ee4-a007-905fc48dd499", "name": "6d9364c1-db81-416b-bf4a-944575d28809", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d5da2654-9c5d-4151-b380-9a54ef5dff84"}}}]}, {"uuid": "c8817eda-96ee-4de0-974b-5a4ee8e2d700", "name": "load_p1rlv15046_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2182c9fd-fd3d-4cb1-b525-192480823e2f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fbcde39a-5be9-4ee4-a007-905fc48dd499"}}}}, {"uuid": "0ed66465-c93e-4bbc-b6d8-f8733570df59", "name": "d483b59c-359c-4b8a-b4ee-4bd199f54e33_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.605318582042619, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.38786447308176675, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82256a60-b4fc-44df-9a90-638422679924", "name": "019726b9-c3ea-4490-adab-f9f7dd742641", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0ed66465-c93e-4bbc-b6d8-f8733570df59"}}}]}, {"uuid": "399a3df4-6083-444d-9d10-92ade5bb7bbe", "name": "load_p1rlv15056_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a914ec3a-4883-42a7-b25d-133a1410b8d9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "82256a60-b4fc-44df-9a90-638422679924"}}}}, {"uuid": "f7a4e74b-d00d-493e-8ed3-48318ab6318d", "name": "74a33022-3750-4c48-9101-1b0b94dab6ab_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.605318582042619, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.38786447308176675, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5833379c-cf4a-404e-bc1f-c2005aa40cef", "name": "ddac8155-a00a-4162-849f-c9787c308814", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f7a4e74b-d00d-493e-8ed3-48318ab6318d"}}}]}, {"uuid": "e2c58061-9dbe-45ce-a721-8992f3b96cae", "name": "load_p1rlv15056_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a914ec3a-4883-42a7-b25d-133a1410b8d9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5833379c-cf4a-404e-bc1f-c2005aa40cef"}}}}, {"uuid": "084827a7-20ea-4302-b255-ff892f846062", "name": "45eed0da-500b-4355-8d8b-3fa3d64c28b7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.038374933892965, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6403266957226059, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c1901508-d644-40b5-af80-37c5ad1ef045", "name": "35ff5b24-e1f4-4870-8339-b09c76f3720c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "084827a7-20ea-4302-b255-ff892f846062"}}}]}, {"uuid": "3f51b6de-6dd3-4676-bb1e-e6b39419098e", "name": "load_p1rlv15064_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "366c9c98-59f1-46d5-b39c-4046703e5e4b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c1901508-d644-40b5-af80-37c5ad1ef045"}}}}, {"uuid": "5e1dd03d-0244-4a37-81c9-224edc02ae81", "name": "ee724805-ca62-43cc-b825-61971b140f9f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.038374933892965, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6403266957226059, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e51d4f22-e74d-40ed-b32e-1e608c2e9942", "name": "7e215efb-c2fa-4670-a122-ab9e908d23c0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5e1dd03d-0244-4a37-81c9-224edc02ae81"}}}]}, {"uuid": "85803038-b368-41b8-a135-3e5c87d7c73e", "name": "load_p1rlv15064_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "366c9c98-59f1-46d5-b39c-4046703e5e4b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e51d4f22-e74d-40ed-b32e-1e608c2e9942"}}}}, {"uuid": "7ef14852-87ee-49f6-a01e-3b2f0d54d045", "name": "7764dae3-4df1-4ec9-a275-9586e0c11678_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5369480608064634, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2969034126636569, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "392c267e-bbf0-4ebf-9128-1bb9f19f45c2", "name": "0e554282-ef8b-4bd7-9f95-bd3134747501", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7ef14852-87ee-49f6-a01e-3b2f0d54d045"}}}]}, {"uuid": "4c962874-3ff5-4ffd-9a2e-03dd51d5caa5", "name": "load_p1rlv15082_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a56b9ad8-c53b-4652-bf94-a7a7dfb8b306"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "392c267e-bbf0-4ebf-9128-1bb9f19f45c2"}}}}, {"uuid": "afd3dd67-a714-44d8-b648-025a873bcc66", "name": "9e168c79-e6f8-46e4-9b5f-308d69d2a3de_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5369480608064634, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2969034126636569, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d78aa811-e5de-47d2-8a6e-ca859e6d274d", "name": "8ffaefe2-8f9b-40ee-8efb-997d246a6f78", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "afd3dd67-a714-44d8-b648-025a873bcc66"}}}]}, {"uuid": "0e534536-98df-4d0e-a2b2-c57f662230ad", "name": "load_p1rlv15082_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a56b9ad8-c53b-4652-bf94-a7a7dfb8b306"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d78aa811-e5de-47d2-8a6e-ca859e6d274d"}}}}, {"uuid": "8a16342a-f4dc-49bc-a03d-0b6ef94b5c8a", "name": "2ee01cca-a911-4d27-b1f1-32145c9f8a0b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.694404982351279, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0468171481890831, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dce3bd76-dd92-4a29-bdae-8f511f6a66de", "name": "1ab69093-721c-4b03-a875-566ccccd6991", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a16342a-f4dc-49bc-a03d-0b6ef94b5c8a"}}}]}, {"uuid": "3ea19cfb-febf-4c3e-834f-4bb5374952c5", "name": "load_p1rlv15109_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "161d4e7b-30f2-447c-a369-1bfa3ba2cd70"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dce3bd76-dd92-4a29-bdae-8f511f6a66de"}}}}, {"uuid": "16f16d5b-6d41-4e21-8374-2b49c353e3ae", "name": "9ffa5173-e5de-4d02-98a8-40351f2d63c0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.694404982351279, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0468171481890831, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f06eae7f-b1db-45c7-8ec8-81018096d1ed", "name": "fc22c1f4-36ec-4c93-83d8-52906a7c3b5c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "16f16d5b-6d41-4e21-8374-2b49c353e3ae"}}}]}, {"uuid": "77da50e4-307b-46ce-9a51-879e6dc63b3e", "name": "load_p1rlv15109_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "161d4e7b-30f2-447c-a369-1bfa3ba2cd70"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f06eae7f-b1db-45c7-8ec8-81018096d1ed"}}}}, {"uuid": "31580ad3-7e99-4aa5-8204-f7f827d1ba17", "name": "451c0e75-b2d5-42a5-a87a-b70884307d2f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9518333270985427, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3340330193202704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "643ee3e6-5e93-441a-adb3-a7e109757722", "name": "e1085673-f52e-4199-b3d0-537d5669de47", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "31580ad3-7e99-4aa5-8204-f7f827d1ba17"}}}]}, {"uuid": "4370f7f8-8420-4bbe-a500-4e4c6f80e0ae", "name": "load_p1rlv15125_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb6d8f13-f04e-4b80-a8dc-e16af1dc860e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "643ee3e6-5e93-441a-adb3-a7e109757722"}}}}, {"uuid": "a85898a5-2e15-440e-b099-8b28ced7c56d", "name": "0308184c-c1ca-4b58-a025-7bfc339d1646_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9518333270985427, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3340330193202704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e72c23e9-be35-479c-b4ad-f19d089ff9f0", "name": "923523d9-abbf-4aa6-b18c-e9c265f73f11", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a85898a5-2e15-440e-b099-8b28ced7c56d"}}}]}, {"uuid": "b13aabec-dc96-44ec-aaeb-f00a782ba1b1", "name": "load_p1rlv15125_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb6d8f13-f04e-4b80-a8dc-e16af1dc860e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e72c23e9-be35-479c-b4ad-f19d089ff9f0"}}}}, {"uuid": "367fdd34-4284-448b-9b5b-14e8c663b7f4", "name": "87f0776a-0237-453d-ad1f-4eb39b4fea02_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.386602840079273, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.360256050049383, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "59541744-25fc-4a62-85f1-6fd5a167211e", "name": "df98da5e-a000-4aa1-873a-297a7e9fd7f6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "367fdd34-4284-448b-9b5b-14e8c663b7f4"}}}]}, {"uuid": "5ed7c0aa-1d90-4cb5-b068-f3bde5ccae4f", "name": "load_p1rlv15163_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdee6d84-9253-4fba-b713-3e41d706e999"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "59541744-25fc-4a62-85f1-6fd5a167211e"}}}}, {"uuid": "6a34efdc-e3cc-45b7-a203-7bf5b2c81eb8", "name": "5786607c-5f81-40a4-889f-ee57750faeb2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.386602840079273, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.360256050049383, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4f3a6f0a-3726-4ff0-9e98-0f1b860ef874", "name": "c46c090a-58bb-49eb-b6be-1396413b297f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6a34efdc-e3cc-45b7-a203-7bf5b2c81eb8"}}}]}, {"uuid": "ba90f2b2-b807-4a1a-b4d7-7610eb475222", "name": "load_p1rlv15163_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdee6d84-9253-4fba-b713-3e41d706e999"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4f3a6f0a-3726-4ff0-9e98-0f1b860ef874"}}}}, {"uuid": "0a6bd41f-0854-469a-bfba-2a896c3a06cd", "name": "2ff222e2-6676-45cd-91b2-7c319b22d5eb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0472938281946713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.40441110210881914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "94810cc7-42eb-448b-86bf-3e77db5adbf2", "name": "12e0771d-de5e-44a2-bf41-a3380bdb0e0b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0a6bd41f-0854-469a-bfba-2a896c3a06cd"}}}]}, {"uuid": "f4cdda81-b2ef-465c-a7ad-ab4debb3e111", "name": "load_p1rlv15170_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d2f8fcb-c279-49d5-88be-39e6a1d1990b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "94810cc7-42eb-448b-86bf-3e77db5adbf2"}}}}, {"uuid": "6ea36083-ee4d-4b49-a387-e7ffb21a84d3", "name": "e38edbdf-acca-456f-9f26-475bd1e7d4ca_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0472938281946713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.40441110210881914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7698473e-55ad-4675-ab96-c68f73e202f5", "name": "f10da870-1a98-4f9d-afa0-1508d9e6ff83", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6ea36083-ee4d-4b49-a387-e7ffb21a84d3"}}}]}, {"uuid": "f5153213-5736-4896-bac5-e95ec3efd810", "name": "load_p1rlv15170_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d2f8fcb-c279-49d5-88be-39e6a1d1990b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7698473e-55ad-4675-ab96-c68f73e202f5"}}}}, {"uuid": "f59209e3-2b75-467b-bf26-981f82c0e69f", "name": "70a64c03-6187-4053-b7cb-e3b2c5bf19e7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.664483224984605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9538644530515166, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "856d1ccc-4a6d-4801-8277-40e6862d50d0", "name": "5f63d5f7-f371-4ccf-9779-492f8bb8b7bc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f59209e3-2b75-467b-bf26-981f82c0e69f"}}}]}, {"uuid": "c2829c3c-272c-4006-ac8d-2617e0370e62", "name": "load_p1rlv15171_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc7cd505-823c-49bb-9e49-3681267dbef0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "856d1ccc-4a6d-4801-8277-40e6862d50d0"}}}}, {"uuid": "d051dd30-ae89-4c67-bd43-6fc4bedd9e0a", "name": "9178c9dd-5219-4698-8f52-aff2f22d2a89_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.664483224984605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9538644530515166, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "122d26a5-f9de-45b9-9ceb-b225d56dc0a6", "name": "f07b5511-be53-44ef-a699-ffefe90618e7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d051dd30-ae89-4c67-bd43-6fc4bedd9e0a"}}}]}, {"uuid": "e9c8b1e2-fa10-41aa-b5e8-0d968a4089c8", "name": "load_p1rlv15171_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc7cd505-823c-49bb-9e49-3681267dbef0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "122d26a5-f9de-45b9-9ceb-b225d56dc0a6"}}}}, {"uuid": "cf9ef428-0e5a-41c0-9c22-c7f3d850f628", "name": "eb19f670-a0bc-4be3-b2a4-fddbb14459d8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.13715702476687, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3795210711832634, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6d52cec0-b460-40fd-81ac-984c9828e283", "name": "5c25944f-08e8-4657-bb47-4a19930fa56b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cf9ef428-0e5a-41c0-9c22-c7f3d850f628"}}}]}, {"uuid": "97641359-1a44-4cd8-bf51-68f7244a794f", "name": "load_p1rlv15180_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e218b01d-f713-4baf-9688-7e77ea413c8c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6d52cec0-b460-40fd-81ac-984c9828e283"}}}}, {"uuid": "0b591a3e-599f-4ac2-ba18-13d14f36399b", "name": "097eb900-2025-4532-bd56-c5e7a836dfd5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.13715702476687, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3795210711832634, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eb3821c5-b7f6-4dc7-a87d-0f997549dd8f", "name": "b2d3304c-0cd9-4650-98f7-ad3323236733", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0b591a3e-599f-4ac2-ba18-13d14f36399b"}}}]}, {"uuid": "80234a72-b646-458d-abc5-b1b670dfbea6", "name": "load_p1rlv15180_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e218b01d-f713-4baf-9688-7e77ea413c8c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eb3821c5-b7f6-4dc7-a87d-0f997549dd8f"}}}}, {"uuid": "ed6adb50-d2ca-49e7-a0af-b3b711ba22b9", "name": "48cad7ff-4b21-496f-9b7e-9111795dc989_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3ad66fff-9252-46e1-b701-234b54d06850", "name": "48cad7ff-4b21-496f-9b7e-9111795dc989_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "489a8e34-f115-4e1f-ba31-2e6c13f264dc", "name": "48cad7ff-4b21-496f-9b7e-9111795dc989_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2222dae9-b9d5-49d4-aa6d-52ccb4e86ffc", "name": "5a1590d8-ac99-4377-8c29-883964d907e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ed6adb50-d2ca-49e7-a0af-b3b711ba22b9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3ad66fff-9252-46e1-b701-234b54d06850"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "489a8e34-f115-4e1f-ba31-2e6c13f264dc"}}}]}, {"uuid": "e5e211ef-445f-464a-84c5-1d7868cc3b32", "name": "load_p1rlv15196", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64634ab5-a5b0-45ae-9763-7d0be029350f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2222dae9-b9d5-49d4-aa6d-52ccb4e86ffc"}}}}, {"uuid": "4f307380-46d3-47c5-bba9-20e079c512ef", "name": "e6b472bb-8ae6-4320-a7b4-b9e96dd4c826_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4727091425662127, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8266013407121705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b8d65bc3-6366-42e6-ac9e-caccf2d56ab6", "name": "d51de9e1-d937-49e5-aae4-012dc576d5af", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4f307380-46d3-47c5-bba9-20e079c512ef"}}}]}, {"uuid": "ddbe7663-6055-4269-bf3f-4f47ab59854f", "name": "load_p1rlv15197_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80a74c6f-c9ec-4742-8fce-ad73c0a6c459"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b8d65bc3-6366-42e6-ac9e-caccf2d56ab6"}}}}, {"uuid": "05ade002-e5e3-4957-983a-7f25931b4b86", "name": "c243d62d-2a4c-4ae1-a4e4-14354d15208b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4727091425662127, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8266013407121705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ca6a98e8-6a77-4566-8bdf-e2588884c9ff", "name": "a28bcc36-e94a-4c0d-9c1d-7c39e9077f4c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "05ade002-e5e3-4957-983a-7f25931b4b86"}}}]}, {"uuid": "774fbd6f-5d4f-41c7-9763-5dd3326edeb4", "name": "load_p1rlv15197_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80a74c6f-c9ec-4742-8fce-ad73c0a6c459"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ca6a98e8-6a77-4566-8bdf-e2588884c9ff"}}}}, {"uuid": "1a64cd3e-a5e7-4c88-a5c9-6a434d68f282", "name": "99fafce9-bcbf-4dbf-b1ea-efde3eec11e6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0052757727111112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4127143879372469, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "53d4034f-4912-4542-8654-099b40e784aa", "name": "c1de5b63-1ec2-43b6-a095-e8a2bd069689", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1a64cd3e-a5e7-4c88-a5c9-6a434d68f282"}}}]}, {"uuid": "14b42caf-a810-40b6-8ce9-ecf6b5736e12", "name": "load_p1rlv15394_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd21ae8b-7841-43b4-871f-316c4b8b4cd2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "53d4034f-4912-4542-8654-099b40e784aa"}}}}, {"uuid": "aaf24261-ff1e-401a-8dc7-a40cd8c20954", "name": "fde98af1-a25f-4925-abb1-965c61a64a24_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0052757727111112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4127143879372469, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "93905f3d-11ae-48b8-a283-dbb7b338bb5e", "name": "b1a83f36-c226-4a2c-a50f-aff46bc2b790", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aaf24261-ff1e-401a-8dc7-a40cd8c20954"}}}]}, {"uuid": "128c9748-eb61-41b0-982c-2c4247dfc49e", "name": "load_p1rlv15394_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd21ae8b-7841-43b4-871f-316c4b8b4cd2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "93905f3d-11ae-48b8-a283-dbb7b338bb5e"}}}}, {"uuid": "992cfd71-f12f-4830-9dec-091fa7812f7d", "name": "7f690059-902d-4fb4-a079-c3235de18eb5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2767849318619047, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.48605417385422345, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "442d77e5-1dca-4571-a3e5-ac4e43a550ed", "name": "1f87872c-f748-4725-a7ea-bceb11b82b15", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "992cfd71-f12f-4830-9dec-091fa7812f7d"}}}]}, {"uuid": "934e91ae-163b-4971-abd3-a22c61cc0d93", "name": "load_p1rlv15399_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ec1f313-f341-498c-b1c2-6669b1cbc629"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "442d77e5-1dca-4571-a3e5-ac4e43a550ed"}}}}, {"uuid": "9248525f-1675-4fc4-9811-af7fd9d4f41c", "name": "3e590369-cf2f-4e43-9c1e-24d74b8f9b9f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2767849318619047, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.48605417385422345, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0b2184b1-a104-41e6-9370-e2099151cc50", "name": "9a3c549e-db8d-45ca-b44e-ec1e12111b3c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9248525f-1675-4fc4-9811-af7fd9d4f41c"}}}]}, {"uuid": "191ea403-3045-4b32-a91f-e399b4afbde0", "name": "load_p1rlv15399_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ec1f313-f341-498c-b1c2-6669b1cbc629"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0b2184b1-a104-41e6-9370-e2099151cc50"}}}}, {"uuid": "f63f659e-6f78-4805-890a-ab555465155b", "name": "0f710b31-0344-4368-9937-9c8df3e60cde_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.962031206451152, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.4366749645571537, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5c0485ab-103f-4e09-adac-9ea1fd468772", "name": "2f07204f-afcd-4e4f-a142-362e75288834", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f63f659e-6f78-4805-890a-ab555465155b"}}}]}, {"uuid": "c089d7eb-49d0-4147-a56e-a1d180a82959", "name": "load_p1rlv15418_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9ca373a-b1c3-464d-bbe3-c05b728beb30"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5c0485ab-103f-4e09-adac-9ea1fd468772"}}}}, {"uuid": "7acbdd19-a91c-419d-b26e-0dfa678951c5", "name": "1095f810-19fd-4e77-acf7-75afaf7eda5e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.962031206451152, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.4366749645571537, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "441f6f39-d3fa-4365-a20e-46ad21d3c6e2", "name": "2e040e4d-bf95-4452-b67f-8367ad8815a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7acbdd19-a91c-419d-b26e-0dfa678951c5"}}}]}, {"uuid": "c713637f-bc7f-4b41-9a3a-30c148f5104e", "name": "load_p1rlv15418_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9ca373a-b1c3-464d-bbe3-c05b728beb30"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "441f6f39-d3fa-4365-a20e-46ad21d3c6e2"}}}}, {"uuid": "d3a9d3fd-1a34-44e4-8200-eee0a284acb4", "name": "b74939b1-fd6e-4f11-8c62-f7dc92cabb82_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.365256087534968, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9406994095530364, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2373d602-d50f-45db-9d74-e71e15007f0e", "name": "2292044b-f6fb-4e61-9d67-9be2743fc8fc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d3a9d3fd-1a34-44e4-8200-eee0a284acb4"}}}]}, {"uuid": "20a84130-1e07-46c3-a786-3c298f7ca770", "name": "load_p1rlv15419_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8bc46399-0276-4ae7-aa8b-4cdd3d3555e8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2373d602-d50f-45db-9d74-e71e15007f0e"}}}}, {"uuid": "f27afbe4-10a3-4ac5-ade2-6bbdd2efb2b0", "name": "cfbae373-28f1-4fdc-ba91-f768f9d0da3f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.365256087534968, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9406994095530364, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ae825d0a-d7ce-4115-ae2e-a1da6ac61fc6", "name": "eded9cdc-5c13-460c-9134-1d7e65e17b67", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f27afbe4-10a3-4ac5-ade2-6bbdd2efb2b0"}}}]}, {"uuid": "be3c7974-aaf8-4b57-9b76-b60866b6f18b", "name": "load_p1rlv15419_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8bc46399-0276-4ae7-aa8b-4cdd3d3555e8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ae825d0a-d7ce-4115-ae2e-a1da6ac61fc6"}}}}, {"uuid": "16476ff1-9623-445d-bc5e-aaa6a2b810a5", "name": "7194d1ad-2e55-4e2b-b643-bb700216f4cb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e1d8e8c1-34c8-4b1c-b9e1-b84b5bbb3cfc", "name": "3a932951-92ce-4fbc-85c0-2c5bcdd3ef0e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "16476ff1-9623-445d-bc5e-aaa6a2b810a5"}}}]}, {"uuid": "ac52531c-a55e-4bf0-b5d2-4d084bb9e315", "name": "load_p1rlv15423_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26009a7e-9bfc-4967-af28-4d8937539eb1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e1d8e8c1-34c8-4b1c-b9e1-b84b5bbb3cfc"}}}}, {"uuid": "c486cd31-8e17-47ee-961e-aec42080087a", "name": "ea850e56-120c-4fac-a9cc-4cddaf1d3bb5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "44f1561b-29cb-47ea-a612-238ac8057242", "name": "187a98ff-7ce4-48b4-a14c-4c538f2bd4eb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c486cd31-8e17-47ee-961e-aec42080087a"}}}]}, {"uuid": "e4273425-20a2-41e6-954c-5ab2df4e2a7a", "name": "load_p1rlv15423_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26009a7e-9bfc-4967-af28-4d8937539eb1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "44f1561b-29cb-47ea-a612-238ac8057242"}}}}, {"uuid": "dbcddb3b-e55f-4b76-9fcf-1d9114e1a182", "name": "f9f528d9-9744-4621-bbec-785f15cc7011_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7411160800233395, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1601349573814363, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "233a1839-ef2e-4e0a-8020-9cb19c9c05ea", "name": "59c9eeb9-e4a9-4356-953a-d0ec6c056115", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dbcddb3b-e55f-4b76-9fcf-1d9114e1a182"}}}]}, {"uuid": "5fc4312b-569e-4e54-b8d5-a8c5e7e0f957", "name": "load_p1rlv15466_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "544be417-0db6-45a7-8314-ec40944781fa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "233a1839-ef2e-4e0a-8020-9cb19c9c05ea"}}}}, {"uuid": "9611ddc9-264a-4100-afb5-47f14ffa366d", "name": "8eb7a877-fc86-45d3-ad46-dff8762e76c8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7411160800233395, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1601349573814363, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "49e70e43-82bf-4626-a209-25e0c3b241f4", "name": "c5532ae5-59cd-4da1-8f85-47d57292a6ea", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9611ddc9-264a-4100-afb5-47f14ffa366d"}}}]}, {"uuid": "bd4cd469-9871-4f86-aa59-8c4c8eeb4afe", "name": "load_p1rlv15466_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "544be417-0db6-45a7-8314-ec40944781fa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "49e70e43-82bf-4626-a209-25e0c3b241f4"}}}}, {"uuid": "9ddeff1c-1865-47b5-9a20-6f4480f52a6a", "name": "74631308-8cae-47cc-9953-c2d80336a11f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7411160800233395, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1601349573814363, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c2945fa0-ff8a-4d7f-8392-1840ea3e35d1", "name": "0c493fbc-aa14-4ae8-951e-aa0d4692833d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9ddeff1c-1865-47b5-9a20-6f4480f52a6a"}}}]}, {"uuid": "1ada6dce-48f3-4868-a6f9-c9413cb6bba8", "name": "load_p1rlv15474_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34e0ffc2-da17-441b-bd4d-26d5a1104712"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c2945fa0-ff8a-4d7f-8392-1840ea3e35d1"}}}}, {"uuid": "0f3eb859-0b60-4406-bf90-21daf8463516", "name": "cb2f7f14-4b4f-4142-ab3d-d86c1f877024_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7411160800233395, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1601349573814363, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5a9977ae-9a9b-4938-9b27-cc4a50d6a106", "name": "d7c4b4ea-d122-4f14-86d5-d8b00795d057", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0f3eb859-0b60-4406-bf90-21daf8463516"}}}]}, {"uuid": "4d230c80-1c74-4403-ac4b-a51751d36efe", "name": "load_p1rlv15474_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34e0ffc2-da17-441b-bd4d-26d5a1104712"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5a9977ae-9a9b-4938-9b27-cc4a50d6a106"}}}}, {"uuid": "bde46da1-4eb0-4327-a607-f4125b62957e", "name": "b4ab7e8c-1e80-4c6d-8097-271037e152d5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.84153235443771, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.447226409705929, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c721f5cd-7665-48e9-822b-b643ca760c4c", "name": "b1002f59-669b-4a7a-b223-b0ce571d42ed", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bde46da1-4eb0-4327-a607-f4125b62957e"}}}]}, {"uuid": "a6d4f5dd-727d-412a-acf1-c047ac85db94", "name": "load_p1rlv15478_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "335df4da-50d2-4fbe-a271-ac04257d35c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c721f5cd-7665-48e9-822b-b643ca760c4c"}}}}, {"uuid": "7b1ce745-357c-4b01-aa87-985d6a6d93ef", "name": "130d584d-ee27-4cf0-b7f9-a354626a372c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.84153235443771, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.447226409705929, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cecd57ee-2d04-4090-8ab6-96fb8a32602c", "name": "d1c5099b-ce74-4f1a-beee-013966dd559c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b1ce745-357c-4b01-aa87-985d6a6d93ef"}}}]}, {"uuid": "5610562d-4d19-4e4b-96d9-2e6f54c7a8d1", "name": "load_p1rlv15478_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "335df4da-50d2-4fbe-a271-ac04257d35c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cecd57ee-2d04-4090-8ab6-96fb8a32602c"}}}}, {"uuid": "10d4058c-cc51-4884-8918-3eabe6c30d8f", "name": "5c33781b-3404-4773-8418-6f4559d102a7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6639c955-f5ea-4a95-8885-340171b23e94", "name": "bc182204-578a-4009-9d2a-53d116b4eb8a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "10d4058c-cc51-4884-8918-3eabe6c30d8f"}}}]}, {"uuid": "339cf270-76e3-42a4-8e2a-30f9527fc3cf", "name": "load_p1rlv15483_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c4e3eac-0b1a-4feb-b39f-079c6d2c1d82"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6639c955-f5ea-4a95-8885-340171b23e94"}}}}, {"uuid": "02eec10f-baad-4d72-8fd2-adfd32006494", "name": "232ddfb9-0f86-4bb7-9e22-c382d8cbeca8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "270f4f58-9952-408d-8edf-87be15ede35d", "name": "24482191-182f-4110-8be8-9af3853180fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "02eec10f-baad-4d72-8fd2-adfd32006494"}}}]}, {"uuid": "5c1376af-a293-4081-a620-91d404fa10f0", "name": "load_p1rlv15483_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c4e3eac-0b1a-4feb-b39f-079c6d2c1d82"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "270f4f58-9952-408d-8edf-87be15ede35d"}}}}, {"uuid": "4d9460f9-f8ea-45a4-a8d8-d4823488d408", "name": "f20cdf6d-fab2-4571-a162-b620ee122f03_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "45439d97-58ce-42f2-bec5-c7b74da13429", "name": "25743876-2804-4dfe-96a3-9e9f6cfed976", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4d9460f9-f8ea-45a4-a8d8-d4823488d408"}}}]}, {"uuid": "5fa72b88-1b29-4b26-a54d-c967ea3e6cd2", "name": "load_p1rlv15484_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6749066f-4739-41ec-8369-8da49dd9e1c8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "45439d97-58ce-42f2-bec5-c7b74da13429"}}}}, {"uuid": "94c50990-e8f0-40b8-a2de-e85f1cdc0cb3", "name": "8257838d-9cc7-4b87-99c8-b8116910d4d4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6ae8cefd-e967-4b54-a346-a5c769ef7a4a", "name": "f817426f-5b7e-4fbc-93b5-7a4f97bf6835", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "94c50990-e8f0-40b8-a2de-e85f1cdc0cb3"}}}]}, {"uuid": "3801303e-0611-4e7b-b70a-2ae965aa8ee3", "name": "load_p1rlv15484_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6749066f-4739-41ec-8369-8da49dd9e1c8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6ae8cefd-e967-4b54-a346-a5c769ef7a4a"}}}}, {"uuid": "2a510bae-755d-43de-b23b-ab8993ce13df", "name": "a8d69f35-1632-45b7-8cd5-541ffa86e572_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5041010955030301, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21577690333785765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "14f155fe-c1f1-44d3-99b0-b99ce0157e64", "name": "8b9a313a-c161-41b2-9dc5-5decb4da3eca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2a510bae-755d-43de-b23b-ab8993ce13df"}}}]}, {"uuid": "6fb69007-5eb9-4a48-9d3b-b7e35932f1b2", "name": "load_p1rlv15487_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "921f8f54-ff83-4d2f-8bf4-ee80bab64ce8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "14f155fe-c1f1-44d3-99b0-b99ce0157e64"}}}}, {"uuid": "bb7f3243-53f3-4af8-901c-e5b6688d9085", "name": "f413b114-08d9-4268-9af4-1a112227dab0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5041010955030301, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21577690333785765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "09e7c2bd-e5e6-47a5-89ee-c10bc7fa7efd", "name": "8d2c276d-6085-4e57-9f7e-cad935bc1bae", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bb7f3243-53f3-4af8-901c-e5b6688d9085"}}}]}, {"uuid": "2f9dfbab-cc48-4d6e-a657-2522ba676563", "name": "load_p1rlv15487_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "921f8f54-ff83-4d2f-8bf4-ee80bab64ce8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "09e7c2bd-e5e6-47a5-89ee-c10bc7fa7efd"}}}}, {"uuid": "4c5a3559-3711-4630-a2cb-1f593c502807", "name": "b30379a4-c9c8-4d1e-a238-a2c504c90b8b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7909002853206712, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1704468602852825, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a291a66b-7b02-4c1e-88d4-80d6f3907695", "name": "10fd141f-c5e0-4494-a3d7-1509990cdf8d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4c5a3559-3711-4630-a2cb-1f593c502807"}}}]}, {"uuid": "e4e71f45-134a-4075-b697-9d222843e30d", "name": "load_p1rlv15488_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6579cc93-2b08-4010-816d-3bef509000cd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a291a66b-7b02-4c1e-88d4-80d6f3907695"}}}}, {"uuid": "3d218d4b-6589-4683-9d50-4f072cf955f9", "name": "a46442de-50e9-4cb2-8bd5-76f12638c054_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7909002853206712, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1704468602852825, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "273f8495-5041-4d50-be86-c5df21cf1202", "name": "e814b988-a237-4f36-a2e0-9eca92db73a3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3d218d4b-6589-4683-9d50-4f072cf955f9"}}}]}, {"uuid": "8ad3ab49-7155-403f-8f7a-db1c665052f7", "name": "load_p1rlv15488_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6579cc93-2b08-4010-816d-3bef509000cd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "273f8495-5041-4d50-be86-c5df21cf1202"}}}}, {"uuid": "9ddaceec-25b1-4e2f-97fe-e0f3bda9eab1", "name": "45abe17e-911f-4a38-90ef-29bf9a2995e1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4163439957648214, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5697938312046736, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f807423-4bcf-462f-9765-e7afcb199c02", "name": "9d8d17ff-60b3-450b-9fa9-181929912aa2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9ddaceec-25b1-4e2f-97fe-e0f3bda9eab1"}}}]}, {"uuid": "b693eeb6-80f6-474f-a21a-04fd615fc669", "name": "load_p1rlv15523_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37ccfa64-1373-49b2-85f6-279abea3c945"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f807423-4bcf-462f-9765-e7afcb199c02"}}}}, {"uuid": "b680a583-c323-4b66-8846-9e0cb1692ee2", "name": "241c0c4f-891a-4ae2-8bd9-8f4b17b2df31_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4163439957648214, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5697938312046736, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "88ae3fc4-dee9-4abb-b7cd-9f1c0c9a2e73", "name": "6b3d4b15-8bbc-4566-bfcc-58aef5610e62", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b680a583-c323-4b66-8846-9e0cb1692ee2"}}}]}, {"uuid": "5ab1fe3e-972c-4829-a87c-bab6ec203b43", "name": "load_p1rlv15523_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37ccfa64-1373-49b2-85f6-279abea3c945"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "88ae3fc4-dee9-4abb-b7cd-9f1c0c9a2e73"}}}}, {"uuid": "bcff2667-a612-43db-b611-5390a5c76156", "name": "896c245a-fddc-4280-b962-53dc8c8b7a65_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2037641724563426, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8275766375494601, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "64635c39-be3f-42a4-b66f-6e623db59e30", "name": "1b4a8ece-7618-47d6-a6ca-d72ab84ae452", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bcff2667-a612-43db-b611-5390a5c76156"}}}]}, {"uuid": "7a60fee1-177c-4473-bb96-ec8044cd167e", "name": "load_p1rlv15525_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6eec860d-08cf-4690-93e6-d909429d363d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "64635c39-be3f-42a4-b66f-6e623db59e30"}}}}, {"uuid": "a56079a2-f22d-4a10-9c2b-2a5a03e028d1", "name": "3353557b-0762-4889-a95f-cbbe120e2d22_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2037641724563426, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8275766375494601, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f5c77b29-b8ef-416b-bd23-ded5d646be5d", "name": "c72c9697-395f-4e8e-8c22-f88adb1c4dbc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a56079a2-f22d-4a10-9c2b-2a5a03e028d1"}}}]}, {"uuid": "ea9b4f68-5e35-439b-a1a2-820e07a5e96b", "name": "load_p1rlv15525_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6eec860d-08cf-4690-93e6-d909429d363d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f5c77b29-b8ef-416b-bd23-ded5d646be5d"}}}}, {"uuid": "f4cd6ac1-0942-444e-a0a8-7c10cdce52b3", "name": "280a77ec-ddcc-443d-993b-a39b278f4390_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.679689620441751, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9077324041357607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "80f4e690-25c1-4a86-87f6-54781fcab371", "name": "b0b7c20a-83e7-4f0c-8716-e548fb66a9f5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f4cd6ac1-0942-444e-a0a8-7c10cdce52b3"}}}]}, {"uuid": "91886b57-b270-4644-aaee-be8a5767e737", "name": "load_p1rlv15542_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b09822b3-a220-48ff-ad4f-62fca602f8b6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "80f4e690-25c1-4a86-87f6-54781fcab371"}}}}, {"uuid": "602a35b7-dba3-42fb-8c10-66468760c864", "name": "ffe9df7b-cc38-4e0f-b2c5-46dff8650db3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.679689620441751, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9077324041357607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c0697a93-163a-4601-81ad-de35e394789c", "name": "455cb216-13e7-48e4-aba4-19da4d9e19cf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "602a35b7-dba3-42fb-8c10-66468760c864"}}}]}, {"uuid": "50d02109-4fa7-425c-b1ec-cf5ea46ed546", "name": "load_p1rlv15542_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b09822b3-a220-48ff-ad4f-62fca602f8b6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c0697a93-163a-4601-81ad-de35e394789c"}}}}, {"uuid": "b5b2ec6f-7406-4e8c-8117-e3743b7aab68", "name": "e5ce500f-b8f4-4f7b-ba76-4a77731bf6f3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7539305984890898, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4187015133753737, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bfce76b1-d370-4fd8-a7f4-a3a9b2e2ce59", "name": "8934b0b2-50fc-4d11-bcbf-0a7501b30eea", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5b2ec6f-7406-4e8c-8117-e3743b7aab68"}}}]}, {"uuid": "e9e2fd04-1682-4241-8f34-246164c32690", "name": "load_p1rlv15603_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "688da57a-6f10-4ef8-8763-202a88c3a495"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bfce76b1-d370-4fd8-a7f4-a3a9b2e2ce59"}}}}, {"uuid": "42e70254-ef9d-47f3-9073-ef5f07401849", "name": "893cabcb-4969-4b8d-910c-775e1f80c569_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7539305984890898, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4187015133753737, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9d85ee74-4d56-475d-8d7d-6a212fd7253b", "name": "e3947cd9-083b-421a-8219-af7133a189fd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "42e70254-ef9d-47f3-9073-ef5f07401849"}}}]}, {"uuid": "67f7ca6b-7c11-434c-8855-4784b10b10f6", "name": "load_p1rlv15603_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "688da57a-6f10-4ef8-8763-202a88c3a495"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9d85ee74-4d56-475d-8d7d-6a212fd7253b"}}}}, {"uuid": "6ffcd115-2598-4bac-bcfc-fb62b8aa15e3", "name": "ad64bf0d-2411-4167-9270-bbf569eec871_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.69722938823788, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6546008506549251, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5bd3bed4-f868-4755-a420-30d0862d64e3", "name": "4be4563f-baab-4b66-a639-dae8729f5310", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6ffcd115-2598-4bac-bcfc-fb62b8aa15e3"}}}]}, {"uuid": "ba1acbf2-320f-4439-a3a9-058703243ea8", "name": "load_p1rlv15606_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c32ce070-e690-4fc1-92ac-f857691de578"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5bd3bed4-f868-4755-a420-30d0862d64e3"}}}}, {"uuid": "f0b37315-8176-4bcd-9b23-2b6f1208dd34", "name": "5ea4e10e-9355-47fc-aefc-ca29575c354e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.69722938823788, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6546008506549251, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e5cbc980-da5d-4976-8239-da70f4814fb8", "name": "38104937-5235-4578-9a80-ed28ecf1f1e0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f0b37315-8176-4bcd-9b23-2b6f1208dd34"}}}]}, {"uuid": "d314859a-4fed-404b-9eb0-4c1bf2504af3", "name": "load_p1rlv15606_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c32ce070-e690-4fc1-92ac-f857691de578"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e5cbc980-da5d-4976-8239-da70f4814fb8"}}}}, {"uuid": "000d3dc0-f13e-4cd1-8023-a518239f75cc", "name": "3e28fefb-5c4e-4f45-9665-959cfbf8e030_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6722127407962883, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033140171384262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "487b316a-6eae-46d8-8da4-a49b958aa033", "name": "41e083f6-fd8b-4d8c-a88c-fbf39b16359a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "000d3dc0-f13e-4cd1-8023-a518239f75cc"}}}]}, {"uuid": "99ab83ce-9bfe-4afe-9493-096f255b300d", "name": "load_p1rlv15607_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32291502-d7be-4b45-8af7-cb217448e73f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "487b316a-6eae-46d8-8da4-a49b958aa033"}}}}, {"uuid": "d0ce0434-a2e1-43af-9811-5850e3713675", "name": "0927996e-7a89-435c-8ac2-9da5f99cdc6f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6722127407962883, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033140171384262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6275d4d4-c7e3-479c-ade6-ca9995459a49", "name": "a78fce1b-9591-4a78-a53e-fef3558fa051", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d0ce0434-a2e1-43af-9811-5850e3713675"}}}]}, {"uuid": "ed46658d-25fa-4de9-93a1-c07bf5b43be0", "name": "load_p1rlv15607_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32291502-d7be-4b45-8af7-cb217448e73f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6275d4d4-c7e3-479c-ade6-ca9995459a49"}}}}, {"uuid": "37e6eb60-0fee-4f18-8a8a-691d4dd6f260", "name": "b17a6cc9-d01c-400d-b251-544ea778886f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.054093584716578, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9114545444360403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8d6d7a31-22b3-4faf-8a02-d37e283c22cb", "name": "6e65c48a-a827-4617-88b1-a1772b15461b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "37e6eb60-0fee-4f18-8a8a-691d4dd6f260"}}}]}, {"uuid": "02ec340a-8c87-4c2b-955e-5aae9a00fb2e", "name": "load_p1rlv15614_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ab2d6dc-f5bb-4320-86f3-bf08bb7cf93f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8d6d7a31-22b3-4faf-8a02-d37e283c22cb"}}}}, {"uuid": "3efb4f1c-9dca-4aa3-87db-2a1037365171", "name": "91fa5bca-4df5-4bf9-a30a-46da7bf654db_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.054093584716578, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9114545444360403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "702de970-2fb2-42de-a18b-eaa10e04da4d", "name": "339375d0-a740-4ced-85a1-ea41a96bd866", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3efb4f1c-9dca-4aa3-87db-2a1037365171"}}}]}, {"uuid": "38b862f2-5180-4529-8e6d-63b195d21ccd", "name": "load_p1rlv15614_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ab2d6dc-f5bb-4320-86f3-bf08bb7cf93f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "702de970-2fb2-42de-a18b-eaa10e04da4d"}}}}, {"uuid": "4ed6d4fa-482b-4e4c-a3af-9717ec5571f1", "name": "04a9c41e-514e-46d8-a981-f56c82f86ab6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0288569450045768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2608148575838028, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "760078dd-1eb6-403e-ae47-5fcb613d909f", "name": "90450a01-a2f4-4bdf-bddf-cf971963920d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4ed6d4fa-482b-4e4c-a3af-9717ec5571f1"}}}]}, {"uuid": "363d5f05-c5c1-45fb-8ad1-72cfdc49b352", "name": "load_p1rlv15617_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6106bbe7-7a47-4c50-8b2a-d46d7432bccf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "760078dd-1eb6-403e-ae47-5fcb613d909f"}}}}, {"uuid": "337b3c0a-48de-4e1f-abb0-f7113dfa905c", "name": "f5a3bfb4-2f3c-4665-8f9e-37812e09fe7d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0288569450045768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2608148575838028, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4af8db5e-535a-4b92-b15a-94b672e51c83", "name": "c364696d-a746-482f-a694-2077f40a5a0a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "337b3c0a-48de-4e1f-abb0-f7113dfa905c"}}}]}, {"uuid": "746f94ee-b1ee-4d67-9ea8-0137b0dd340f", "name": "load_p1rlv15617_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6106bbe7-7a47-4c50-8b2a-d46d7432bccf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4af8db5e-535a-4b92-b15a-94b672e51c83"}}}}, {"uuid": "118b10ed-dfde-40ac-bce5-9b60a224ee16", "name": "c423dd2c-9fdf-45de-a9ca-ae80ac1330ca_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3483029031483318, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6505451661884267, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c096a36-d6ee-4d43-8f51-db90300a191b", "name": "17e66d5e-3d71-4238-ad31-0c9e1bd1cea6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "118b10ed-dfde-40ac-bce5-9b60a224ee16"}}}]}, {"uuid": "9b240a29-afa4-4865-8113-dce61285e40a", "name": "load_p1rlv15622_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1151b559-3ae0-4863-9363-9b395bbfc403"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c096a36-d6ee-4d43-8f51-db90300a191b"}}}}, {"uuid": "2b7add0b-c3d1-4d2e-a2a9-20a31032ceaf", "name": "221e5460-385d-4650-90cb-ba64d3817077_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3483029031483318, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6505451661884267, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9f4c6cc9-7df8-41ef-b43b-9b6fa5d9299d", "name": "3a46e619-76b4-44c1-b1e1-10acbd222b4d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2b7add0b-c3d1-4d2e-a2a9-20a31032ceaf"}}}]}, {"uuid": "960c7b61-0dcc-4347-ad5f-706dd7dd4230", "name": "load_p1rlv15622_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1151b559-3ae0-4863-9363-9b395bbfc403"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9f4c6cc9-7df8-41ef-b43b-9b6fa5d9299d"}}}}, {"uuid": "4e34e414-770f-4d2a-8a5b-2541c00f2c38", "name": "4fda3b3e-5dfa-4b73-8a3d-f338684f3ebe_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 12.451565419664076, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.11178199687988, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e87b6646-27e9-40f3-b312-4ae56d20f783", "name": "4fda3b3e-5dfa-4b73-8a3d-f338684f3ebe_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 12.451565419664076, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.11178199687988, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "544c217e-5f15-498a-9750-46173095f189", "name": "4fda3b3e-5dfa-4b73-8a3d-f338684f3ebe_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 12.451565419664076, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.11178199687988, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5619dbe0-729d-496b-a53c-dfa9b5098b3d", "name": "6cd198bd-eba6-4100-9ef6-fd07bee7d54e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4e34e414-770f-4d2a-8a5b-2541c00f2c38"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e87b6646-27e9-40f3-b312-4ae56d20f783"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "544c217e-5f15-498a-9750-46173095f189"}}}]}, {"uuid": "81a3d98f-432e-40e7-9b4c-5838469bd7f6", "name": "load_p1rlv15628", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13eabcb1-332a-4c7a-8042-214ada721424"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5619dbe0-729d-496b-a53c-dfa9b5098b3d"}}}}, {"uuid": "0d0d1323-1ea5-4f85-b268-c6c09adbb522", "name": "8d1d965a-01d1-4b25-85ba-b67975992f72_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0240502132333855, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5295456567023789, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fc8b04d3-ff3a-4865-8fde-5b1bd3b1a8ad", "name": "9b6b6641-24b2-4219-9311-1328277c753a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0d0d1323-1ea5-4f85-b268-c6c09adbb522"}}}]}, {"uuid": "d3b8c2d1-689b-453e-91e9-7b2d36b89d4d", "name": "load_p1rlv15629_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec0bca53-a58b-4004-8dba-8defca9db4c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fc8b04d3-ff3a-4865-8fde-5b1bd3b1a8ad"}}}}, {"uuid": "8fd15230-b131-4c8c-8c58-3f1431ff2688", "name": "c3d46240-f821-4126-bc47-1abfa5d04a49_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0240502132333855, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5295456567023789, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "584328b2-9bf0-49d5-ba52-666575ee7fe6", "name": "e9380927-a696-4fef-ad69-eb89d8704985", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8fd15230-b131-4c8c-8c58-3f1431ff2688"}}}]}, {"uuid": "0ce4f795-f79d-4360-9d3d-c469cefe50ef", "name": "load_p1rlv15629_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec0bca53-a58b-4004-8dba-8defca9db4c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "584328b2-9bf0-49d5-ba52-666575ee7fe6"}}}}, {"uuid": "07faca36-6635-455b-bb11-e5d33dc5fb41", "name": "7a86b912-7590-4f5c-8842-22c89ee1209f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.459276697523187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8425022918187992, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f26f51b1-e972-4612-b052-a598f9da1ed2", "name": "ce8fc209-c9b3-4f81-8c4c-b966dc154461", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "07faca36-6635-455b-bb11-e5d33dc5fb41"}}}]}, {"uuid": "3c23a9e5-e695-4862-a1ed-1b7013922081", "name": "load_p1rlv15634_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5af6dae-d20f-4a31-9544-b9455cd639bd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f26f51b1-e972-4612-b052-a598f9da1ed2"}}}}, {"uuid": "062c5c69-88c0-4ff2-ad09-c6b4f4e6e5c7", "name": "e977cde3-24e0-48e7-952e-4cd42a95a60b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.459276697523187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8425022918187992, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "29e202bb-523d-4a00-92c4-a61cf33b8014", "name": "a8451a90-b696-43d8-9d36-15a3a6a6e378", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "062c5c69-88c0-4ff2-ad09-c6b4f4e6e5c7"}}}]}, {"uuid": "2bec8ef3-d1d1-4375-b3ad-4fcd521998da", "name": "load_p1rlv15634_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5af6dae-d20f-4a31-9544-b9455cd639bd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "29e202bb-523d-4a00-92c4-a61cf33b8014"}}}}, {"uuid": "f4c2e805-198e-4d18-93b9-2bef44ea8c3a", "name": "df77f211-3a0a-498a-89e3-b082fc8ee120_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6524083002915736, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21201745820683848, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "157134c6-e79c-411e-91d9-9ea70e645daa", "name": "57a7b7d3-f679-41f1-9db7-41157808fb4f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f4c2e805-198e-4d18-93b9-2bef44ea8c3a"}}}]}, {"uuid": "48fe9c33-79f4-47bd-9ba3-6a4d2b94dcef", "name": "load_p1rlv15638_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2715a637-d6f0-4e7b-b43e-20836bf4e614"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "157134c6-e79c-411e-91d9-9ea70e645daa"}}}}, {"uuid": "d17d3786-2de1-4665-8df1-993edcc55061", "name": "2ac54f16-2236-410d-99e9-770bb50b4cd1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6524083002915736, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21201745820683848, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "973e1374-c51c-4bbb-b95f-6b9283457b45", "name": "a7af89c0-c088-456c-baf2-7af4041c5da8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d17d3786-2de1-4665-8df1-993edcc55061"}}}]}, {"uuid": "4b180f70-5021-40fe-a7f3-6558f7c9cbd0", "name": "load_p1rlv15638_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2715a637-d6f0-4e7b-b43e-20836bf4e614"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "973e1374-c51c-4bbb-b95f-6b9283457b45"}}}}, {"uuid": "34ae07d1-4965-456f-83b7-f0911007dd8b", "name": "ee1d6b15-d1a0-4357-b0bd-3694826cf032_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1219512592986662, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8685822493081499, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "609d6800-53ba-4091-b201-c639a89f9b22", "name": "14b4f633-e879-4cc6-a1e6-73404bf779da", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "34ae07d1-4965-456f-83b7-f0911007dd8b"}}}]}, {"uuid": "8a26e622-7b55-4e5d-a0c0-c74de1ab2a4d", "name": "load_p1rlv15645_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "449098c3-4f65-4350-863f-4b7bc1f14493"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "609d6800-53ba-4091-b201-c639a89f9b22"}}}}, {"uuid": "6705cba9-52b3-44f6-be0d-5b207c79af4e", "name": "b14e774b-701d-4159-be78-c4cb209404a7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1219512592986662, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8685822493081499, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "292da20d-3df1-41dd-bedc-52931193eedc", "name": "e58612bc-30a2-4e29-b570-95ec6244c410", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6705cba9-52b3-44f6-be0d-5b207c79af4e"}}}]}, {"uuid": "b156a757-1c66-49db-9928-f98fc3643bce", "name": "load_p1rlv15645_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "449098c3-4f65-4350-863f-4b7bc1f14493"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "292da20d-3df1-41dd-bedc-52931193eedc"}}}}, {"uuid": "d3bc3cbe-2ba2-483c-9915-bcb5ce6828ef", "name": "9a5d157c-5747-4591-9475-03cad3a8c47e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.567401274738218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6497123013243786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "343e3115-3ac2-45ff-bdd7-ba9f1eeef288", "name": "137085b1-cbcb-4fee-a841-5b1852556baa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d3bc3cbe-2ba2-483c-9915-bcb5ce6828ef"}}}]}, {"uuid": "c7d94431-5e19-498e-820d-04507086783f", "name": "load_p1rlv16114_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5984e209-9f0e-4844-91e6-902c8329f13c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "343e3115-3ac2-45ff-bdd7-ba9f1eeef288"}}}}, {"uuid": "563d990f-0a48-4bd7-b6be-72ff20388a91", "name": "711144a8-1d7f-4d35-a0a6-e068c2cad6a0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.567401274738218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6497123013243786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "905c6c36-2f29-4f53-9434-9f23eac4da33", "name": "7231060f-4920-43b1-8d1f-19720e20748a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "563d990f-0a48-4bd7-b6be-72ff20388a91"}}}]}, {"uuid": "2d1287d2-7d33-4437-b0d3-ec9948e8b482", "name": "load_p1rlv16114_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5984e209-9f0e-4844-91e6-902c8329f13c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "905c6c36-2f29-4f53-9434-9f23eac4da33"}}}}, {"uuid": "4aadcbeb-c078-40bf-85e3-dc67375c909d", "name": "13cd89b5-b77c-4a31-9214-e520fd74f0ab_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7463758536661063, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1812611818115355, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "13578549-07e9-4bbe-ae2d-0e6934e18e02", "name": "44ce35c9-dc72-4262-bf60-5f311fe0d931", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4aadcbeb-c078-40bf-85e3-dc67375c909d"}}}]}, {"uuid": "271b69d3-beeb-4543-b1cf-1f1820fc4db1", "name": "load_p1rlv16115_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52d1b79d-5c6b-4b44-9998-600c6debd999"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "13578549-07e9-4bbe-ae2d-0e6934e18e02"}}}}, {"uuid": "7d7debbd-e8f9-4216-b4e4-0ae296e425e7", "name": "443a895b-503d-424b-a6d4-48b372820048_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7463758536661063, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1812611818115355, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "20226c39-1722-4a0b-8de8-c3711613ea03", "name": "f44b6716-a448-474e-b9ec-2dd11690db6e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7d7debbd-e8f9-4216-b4e4-0ae296e425e7"}}}]}, {"uuid": "96585543-3d95-45a8-bdc5-a5c1a3ec6ad6", "name": "load_p1rlv16115_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52d1b79d-5c6b-4b44-9998-600c6debd999"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "20226c39-1722-4a0b-8de8-c3711613ea03"}}}}, {"uuid": "7eaaac68-1b01-4f3f-8872-e0a5be83a3b3", "name": "d8d7bb65-b83f-4950-84a4-763f72a4230a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.915650640127065, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8660189470929796, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aefbedba-7672-4b17-9874-24e2cd6fb05a", "name": "55329a86-bb37-49ad-8576-42ccfd21db71", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7eaaac68-1b01-4f3f-8872-e0a5be83a3b3"}}}]}, {"uuid": "88bb12b4-c9e0-438a-9efc-f9ffaeb42d1d", "name": "load_p1rlv16116_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "972f8088-b67b-47d0-a86f-49179dfb1c92"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aefbedba-7672-4b17-9874-24e2cd6fb05a"}}}}, {"uuid": "04857d11-51c4-4ba0-ace8-5adbbacb71ea", "name": "b2e208d9-3790-47b8-b509-ceac371b0cbd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.915650640127065, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8660189470929796, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3098cd40-5dd6-4996-b1bc-fc3eb5f29afe", "name": "7060432c-11ff-45fc-bb69-17cfbbdfb27c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "04857d11-51c4-4ba0-ace8-5adbbacb71ea"}}}]}, {"uuid": "20214244-ec78-4484-b061-527c9dcfdbd9", "name": "load_p1rlv16116_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "972f8088-b67b-47d0-a86f-49179dfb1c92"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3098cd40-5dd6-4996-b1bc-fc3eb5f29afe"}}}}, {"uuid": "e40a3821-f79c-41ff-a11f-257beeec8693", "name": "a4c79aa9-b586-4019-a8cc-1f031e7905d7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8805170689043904, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.699573894302905, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f706d3b6-bcec-4143-947c-09637f36eb4b", "name": "4a9a3c69-4fac-494e-911d-a58c92abf5fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e40a3821-f79c-41ff-a11f-257beeec8693"}}}]}, {"uuid": "728535a5-4d13-458c-aa9a-988562645181", "name": "load_p1rlv16117_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "204899ec-81e4-4a72-bf70-69b3428a49a1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f706d3b6-bcec-4143-947c-09637f36eb4b"}}}}, {"uuid": "abced025-b8ad-43f5-b022-9c333946660d", "name": "fd6642d2-1b4c-4abb-a17c-1b3bc7447566_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8805170689043904, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.699573894302905, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "70e0dfdd-638f-4f98-ab98-9c223d03f62a", "name": "24ccfd03-28f7-438c-b20e-4534cf87b92e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "abced025-b8ad-43f5-b022-9c333946660d"}}}]}, {"uuid": "fe1c3a28-1973-4061-9d97-344b8b71c76b", "name": "load_p1rlv16117_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "204899ec-81e4-4a72-bf70-69b3428a49a1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "70e0dfdd-638f-4f98-ab98-9c223d03f62a"}}}}, {"uuid": "bac6a7f5-ae27-4fe8-a7cf-97cddabffe8c", "name": "e7fc5122-4ade-4b30-ade6-8435292aa7a3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.667455481738122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8122169683202977, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a44049d7-2b72-4a70-ae59-d4cf28f4dd96", "name": "dfd9db79-c670-4723-b1e2-f1d594819506", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bac6a7f5-ae27-4fe8-a7cf-97cddabffe8c"}}}]}, {"uuid": "a54790f2-6d25-4017-8b73-843660042c32", "name": "load_p1rlv16118_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bca0b3a0-d4cb-4a4a-9b14-aa23d9e5e5fe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a44049d7-2b72-4a70-ae59-d4cf28f4dd96"}}}}, {"uuid": "80b5eeea-9887-41a7-85cb-7fe8263902b9", "name": "1287e37f-dfea-4530-88d3-63e5043f53ba_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.667455481738122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8122169683202977, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "982851d7-722b-4f52-80d3-f957ddec7727", "name": "c6aae283-785e-4c94-99c2-c8e66c57a1c1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "80b5eeea-9887-41a7-85cb-7fe8263902b9"}}}]}, {"uuid": "ffeafe96-58a7-470c-8b86-2f5b72c44780", "name": "load_p1rlv16118_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bca0b3a0-d4cb-4a4a-9b14-aa23d9e5e5fe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "982851d7-722b-4f52-80d3-f957ddec7727"}}}}, {"uuid": "25bbbf41-6602-406b-a32c-c824e7d3bce3", "name": "0b667be0-259d-40f1-9575-2c4e63ff572c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7938373145978153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7193647721316423, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "32413a08-1791-444a-ba67-b830c75c7308", "name": "9a1dab1c-b535-4779-8363-a9f1fe9c4feb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "25bbbf41-6602-406b-a32c-c824e7d3bce3"}}}]}, {"uuid": "9dfd712f-d2cf-46ce-9818-46b2e312025e", "name": "load_p1rlv16119_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0d6e608-d5bf-40d6-9efd-f3b0922e7d77"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "32413a08-1791-444a-ba67-b830c75c7308"}}}}, {"uuid": "786605ce-febf-4166-a149-578bf4bb7da0", "name": "cd48b049-2a20-4ed6-b62c-246263e50b6e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7938373145978153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7193647721316423, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "97395db4-d9c1-4d66-aebe-354134b5507e", "name": "9b4fcdb4-3f1c-4478-8682-b5bb89d111fa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "786605ce-febf-4166-a149-578bf4bb7da0"}}}]}, {"uuid": "6c33851b-87c1-46b9-b27f-c13e571c86ce", "name": "load_p1rlv16119_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0d6e608-d5bf-40d6-9efd-f3b0922e7d77"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "97395db4-d9c1-4d66-aebe-354134b5507e"}}}}, {"uuid": "9379c229-f655-4b12-b5b2-ba95f386a272", "name": "bbd65c20-107d-4409-bdde-9ece0c47256b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3480679486659737, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1241770602848328, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "98069f9e-e37e-45ff-99c5-a57a5a77b0b6", "name": "39a00932-92f4-4396-9859-712f0cd45ddc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9379c229-f655-4b12-b5b2-ba95f386a272"}}}]}, {"uuid": "36732ab5-69dc-40c4-9af4-545e9f2c1d0e", "name": "load_p1rlv16124_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6da4b2d0-66c7-43fb-9aab-3bbac03aa989"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "98069f9e-e37e-45ff-99c5-a57a5a77b0b6"}}}}, {"uuid": "7fcc4de7-0719-40e5-9825-8270e73b0247", "name": "a89a7b08-6b09-47c6-a293-ac726779012b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3480679486659737, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1241770602848328, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a6ed8840-408f-46f0-8c09-e37395a9689c", "name": "33f4efba-208a-4673-b449-f8178987c22c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7fcc4de7-0719-40e5-9825-8270e73b0247"}}}]}, {"uuid": "4fc30b64-b173-47ad-955a-f430d7614906", "name": "load_p1rlv16124_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6da4b2d0-66c7-43fb-9aab-3bbac03aa989"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a6ed8840-408f-46f0-8c09-e37395a9689c"}}}}, {"uuid": "84b6495b-045c-4c87-964c-fb0e558e77de", "name": "4c9cc6ed-5aa4-4a20-888b-79f41b0769f6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6733980323267108, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22626974414284334, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4c058a44-e6ea-4de2-bfb9-d76d5ea629b5", "name": "774e1dff-e6e3-4619-ab4b-3303bc8b65c0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "84b6495b-045c-4c87-964c-fb0e558e77de"}}}]}, {"uuid": "d7ba0cd2-bb48-4804-a327-3721f52bfcea", "name": "load_p1rlv16126_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd41f55a-4b5d-4c19-9787-801072b3b946"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4c058a44-e6ea-4de2-bfb9-d76d5ea629b5"}}}}, {"uuid": "d2d481de-1a78-47c2-86e7-445c35b9b344", "name": "a5af0b62-a953-4f46-8b72-045b3490302b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6733980323267108, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22626974414284334, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "516af154-ecbc-4845-8119-06afe55f66f3", "name": "5ffd92d1-5896-49c7-9684-bf107e2205c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d2d481de-1a78-47c2-86e7-445c35b9b344"}}}]}, {"uuid": "8d7846f5-8730-4e0d-88f5-3e63a4dcc72d", "name": "load_p1rlv16126_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd41f55a-4b5d-4c19-9787-801072b3b946"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "516af154-ecbc-4845-8119-06afe55f66f3"}}}}, {"uuid": "5f332d82-e662-4f4d-ab2a-35c89f90831e", "name": "8905e9c5-ac07-4274-9110-4be751a1f451_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5788343693478561, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0852895205351165, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "04912ec8-5a17-4a85-84f7-0c39abc03477", "name": "746ffaf8-e596-4d3e-82fc-8d4900947fd5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5f332d82-e662-4f4d-ab2a-35c89f90831e"}}}]}, {"uuid": "0a976511-8ae9-4638-8c2c-63edd65633a5", "name": "load_p1rlv16133_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "102b9460-ea9a-4099-b16f-40b8fdf99ef7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "04912ec8-5a17-4a85-84f7-0c39abc03477"}}}}, {"uuid": "43a599a2-b62b-4612-8d2f-5884d76620fd", "name": "0d6082fc-9bea-4439-bc0d-ac1ef6436de8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5788343693478561, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0852895205351165, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9139257c-f68d-4bf2-9810-823f373b594a", "name": "342dc2c1-513f-46d8-b794-8d02a17882cd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "43a599a2-b62b-4612-8d2f-5884d76620fd"}}}]}, {"uuid": "74dd4588-7d28-4eb5-9a8d-313f8d179c7e", "name": "load_p1rlv16133_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "102b9460-ea9a-4099-b16f-40b8fdf99ef7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9139257c-f68d-4bf2-9810-823f373b594a"}}}}, {"uuid": "c0619dfd-a505-47a8-9336-79b3ec4dfb0c", "name": "0ca9810b-c5a2-430d-b6fa-554f188fa7fb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6153595559076463, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2889565281407196, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50198a08-3a43-40dc-8571-73b5bb9cd346", "name": "bfabcc6a-d17b-45ff-a2bd-afb9646f33d0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c0619dfd-a505-47a8-9336-79b3ec4dfb0c"}}}]}, {"uuid": "a2a22920-3529-4a47-9552-fee1019b5ed2", "name": "load_p1rlv16135_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "676de1a3-2dfd-4faa-a057-7739e825d136"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50198a08-3a43-40dc-8571-73b5bb9cd346"}}}}, {"uuid": "5043792a-ef7c-4496-a15d-0af4f7af8cce", "name": "9ed3f16b-eb01-4ebd-8e6a-5e66e0002290_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6153595559076463, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2889565281407196, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dcca11b3-d501-43f0-a281-3bc327b529ce", "name": "4a16d233-6640-4ea1-b6d8-ecb6386d9d6c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5043792a-ef7c-4496-a15d-0af4f7af8cce"}}}]}, {"uuid": "e470734e-dcd9-48c2-815a-0c9c72d1085d", "name": "load_p1rlv16135_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "676de1a3-2dfd-4faa-a057-7739e825d136"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dcca11b3-d501-43f0-a281-3bc327b529ce"}}}}, {"uuid": "cbc9698a-1fef-4fad-8688-d01851548ad5", "name": "7b8bc565-3431-4565-aa4f-646ed7b35c4c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0226237890173833, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.014132802344601372, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aef4db55-d145-4590-8c3a-d09b87ccc493", "name": "3cff0272-99e6-4877-af42-f17a0280d099", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cbc9698a-1fef-4fad-8688-d01851548ad5"}}}]}, {"uuid": "5829fc66-d124-4fd0-973b-6a56109a6c70", "name": "load_p1rlv16139_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c840cf3f-be15-448b-8c03-8942c586b135"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aef4db55-d145-4590-8c3a-d09b87ccc493"}}}}, {"uuid": "610f4b2f-b458-4e1a-a61a-d6632506d009", "name": "b4ba9738-c756-4d73-b5b0-0e95b8cd887d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0226237890173833, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.014132802344601372, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8d4da3d0-1148-4838-9d94-9ade8464da1e", "name": "0260069a-20b1-4411-94cc-9ffb795ebca1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "610f4b2f-b458-4e1a-a61a-d6632506d009"}}}]}, {"uuid": "91c435bb-76f2-471a-809d-13817bea407c", "name": "load_p1rlv16139_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c840cf3f-be15-448b-8c03-8942c586b135"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8d4da3d0-1148-4838-9d94-9ade8464da1e"}}}}, {"uuid": "6042efec-a7ab-418b-92e5-3ab83efbb079", "name": "56214b0e-f9e7-491d-a861-a80f43f5f299_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2601927423507288, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13915962527089715, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f6b6d87d-8daf-4cbb-9619-84739c833ecb", "name": "7a214c76-fcac-455f-b323-84b6a728afad", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6042efec-a7ab-418b-92e5-3ab83efbb079"}}}]}, {"uuid": "47b4cccd-4f53-45f0-9b6e-01951fc190d6", "name": "load_p1rlv16146_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6d21c357-1033-45e1-84a0-b82ceafe6ab8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f6b6d87d-8daf-4cbb-9619-84739c833ecb"}}}}, {"uuid": "fd23a6b8-cf91-41dc-b37f-77c1188910ba", "name": "f5874288-2c7b-457e-a546-a9300f69e414_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2601927423507288, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13915962527089715, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c729d70-656f-48bf-874f-573f7d3fad6c", "name": "d42b61b5-1b5d-4c92-8376-63d5c0d743ef", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fd23a6b8-cf91-41dc-b37f-77c1188910ba"}}}]}, {"uuid": "3b572804-1bf4-452f-8c8a-7e83f2a7df9d", "name": "load_p1rlv16146_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6d21c357-1033-45e1-84a0-b82ceafe6ab8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c729d70-656f-48bf-874f-573f7d3fad6c"}}}}, {"uuid": "944e9d08-58c5-471c-b02f-d03631e3b3fd", "name": "4cf50889-ff51-4daa-9594-f9ca031ddf2f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.954715654212962, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.874926311982217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ba4c0a9a-ea5a-47e6-9087-6ccffa088ae3", "name": "06820ee3-82e9-4d51-8bd8-82afe2e820d6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "944e9d08-58c5-471c-b02f-d03631e3b3fd"}}}]}, {"uuid": "e1d9d634-aada-4a41-9782-7b61414d440c", "name": "load_p1rlv16149_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b15792ca-a6bd-47e5-8c67-5c3076174848"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ba4c0a9a-ea5a-47e6-9087-6ccffa088ae3"}}}}, {"uuid": "d82e6c12-c88d-44bf-acac-1c129736f972", "name": "60850e0b-cb39-4f3d-8296-63d7efa32f9f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.954715654212962, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.874926311982217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d0d23c7c-b137-4edb-aa89-8cd506803c05", "name": "1f02f919-b8d7-4dcc-be93-0416be171418", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d82e6c12-c88d-44bf-acac-1c129736f972"}}}]}, {"uuid": "eee641f4-7495-49d4-b0c4-ccad20246869", "name": "load_p1rlv16149_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b15792ca-a6bd-47e5-8c67-5c3076174848"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d0d23c7c-b137-4edb-aa89-8cd506803c05"}}}}, {"uuid": "3fb5e67e-7604-49e0-84b3-242f0a723658", "name": "4f023723-4c1c-4054-982b-8b339729e62e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.199861964544811, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5137601155429989, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "babc2fd3-3af8-477f-83da-3053e5d55d9a", "name": "3a352fc0-24f9-40ff-a303-68dd6b65b760", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3fb5e67e-7604-49e0-84b3-242f0a723658"}}}]}, {"uuid": "62d2f921-6b29-450f-8efd-cc005b8fc836", "name": "load_p1rlv16156_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "74edd9e9-24a5-4b36-8ca8-24ef2fa3e972"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "babc2fd3-3af8-477f-83da-3053e5d55d9a"}}}}, {"uuid": "c638bf32-7feb-4a80-98d7-3f15f7f07683", "name": "c15e25d9-ee81-47b4-93ca-1da39af6a5ec_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.199861964544811, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5137601155429989, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "02dc8948-4499-440f-9062-51b4df1185ed", "name": "af9e2be7-aec7-47c4-9506-4e350d02b583", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c638bf32-7feb-4a80-98d7-3f15f7f07683"}}}]}, {"uuid": "ea4d056f-ebac-4652-a3bb-2f0393cf3e9b", "name": "load_p1rlv16156_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "74edd9e9-24a5-4b36-8ca8-24ef2fa3e972"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "02dc8948-4499-440f-9062-51b4df1185ed"}}}}, {"uuid": "95af027f-f060-48cf-ba7f-7a6bfe81e4d9", "name": "7444f369-9eab-404e-875f-0a874429e148_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8668291909105112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7572719732007044, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2977e7e4-a182-4eda-a621-665cdfea8b72", "name": "7723bebb-c070-4919-b2a4-43332f162739", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "95af027f-f060-48cf-ba7f-7a6bfe81e4d9"}}}]}, {"uuid": "f8017a87-cdf4-45bd-82eb-e1c5d21ff905", "name": "load_p1rlv16157_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6efff4f7-c67b-4cfb-a72d-30b6616825b1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2977e7e4-a182-4eda-a621-665cdfea8b72"}}}}, {"uuid": "0d1ea309-327f-4df9-a825-c720410aea31", "name": "2cd1e795-b6d5-4a6c-aed6-ef98f90064e8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8668291909105112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7572719732007044, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2f7cb9e1-5e4f-43bc-adab-f41910e887df", "name": "0e55a0a1-2deb-495a-9a56-f39a4c2ff82b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0d1ea309-327f-4df9-a825-c720410aea31"}}}]}, {"uuid": "289f48fe-200b-4ef8-bb85-415fb62457eb", "name": "load_p1rlv16157_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6efff4f7-c67b-4cfb-a72d-30b6616825b1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2f7cb9e1-5e4f-43bc-adab-f41910e887df"}}}}, {"uuid": "aadd63b4-0be3-4930-aa43-d0e89a049dde", "name": "340caec7-a6a9-4f57-a9f1-7c0cdd25330e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.927062407458527, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.5614641711041375, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "94718418-e166-4c74-a9f9-afa3c38c5c5e", "name": "10bccbfd-02a7-465a-ae9d-34e6334107d8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aadd63b4-0be3-4930-aa43-d0e89a049dde"}}}]}, {"uuid": "ad302c42-a4e0-4487-baea-30eb493be87c", "name": "load_p1rlv16158_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b85e180a-8eb4-4acc-a816-d99758cc16ea"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "94718418-e166-4c74-a9f9-afa3c38c5c5e"}}}}, {"uuid": "35d8cb9b-ea2b-4ad7-84b6-3ea93abe91cd", "name": "14d8755e-45f8-4f0a-ace9-26a251575b0d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.927062407458527, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.5614641711041375, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e7a4f331-391c-41c2-8708-af3c62c444b1", "name": "ad66d882-04f1-42ea-9b5d-85bf29f490a6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "35d8cb9b-ea2b-4ad7-84b6-3ea93abe91cd"}}}]}, {"uuid": "3d2b97fa-a69b-400b-8c6a-7edcc9ec5e98", "name": "load_p1rlv16158_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b85e180a-8eb4-4acc-a816-d99758cc16ea"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e7a4f331-391c-41c2-8708-af3c62c444b1"}}}}, {"uuid": "8fa57b6a-1070-49a0-ab8c-6fc7653fa1b5", "name": "d8de8e69-c8e2-40bf-ab7d-b1efcb08417f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6923563615826267, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8186846587164974, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f8c69361-b012-4381-9baf-f47e2ace3e35", "name": "7352512f-5a4e-42bf-a268-c90fbaa10bfb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8fa57b6a-1070-49a0-ab8c-6fc7653fa1b5"}}}]}, {"uuid": "ae35f4ab-be01-4151-b28c-bc457b2eaf1e", "name": "load_p1rlv16168_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fb5abb7-dd79-49aa-9185-88a90bb45bc7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f8c69361-b012-4381-9baf-f47e2ace3e35"}}}}, {"uuid": "5518dcf0-ca6d-4c31-8e14-b1fbfcbfc9a4", "name": "8f65fe76-7ec3-4c39-8ade-f8cda2b5adb4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6923563615826267, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8186846587164974, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ee0339eb-6bb9-4623-a309-40f8be220020", "name": "7b56c783-647d-4445-a892-aeeeb23f2214", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5518dcf0-ca6d-4c31-8e14-b1fbfcbfc9a4"}}}]}, {"uuid": "e1291582-16b4-44ff-8b20-af36b4546a35", "name": "load_p1rlv16168_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fb5abb7-dd79-49aa-9185-88a90bb45bc7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ee0339eb-6bb9-4623-a309-40f8be220020"}}}}, {"uuid": "759b6c81-1eff-41f0-91b3-2fa957406b90", "name": "6ceb5dc2-80f4-4575-a4de-ab9a62fd34ed_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.160237576416993, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 5.832362811342285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9e794faa-cc78-43af-92ad-d55e903534c0", "name": "79d156a2-e7af-4303-a866-c151ec2d5e3b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "759b6c81-1eff-41f0-91b3-2fa957406b90"}}}]}, {"uuid": "d37c76fa-d11a-45d6-b583-c9f1d1afe258", "name": "load_p1rlv16177_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbbe8401-53a1-4ce7-9ce1-02f547055d95"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9e794faa-cc78-43af-92ad-d55e903534c0"}}}}, {"uuid": "1ef1acd9-ea6f-4427-8451-dd0f3a5e227b", "name": "ece91088-fedf-4f6c-8fd4-020c63ffe0ae_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.160237576416993, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 5.832362811342285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "11f69efc-00f8-446d-a326-f00471de567f", "name": "ecf2035a-b5a3-40e3-8b14-7cc42e5d2d52", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1ef1acd9-ea6f-4427-8451-dd0f3a5e227b"}}}]}, {"uuid": "11b248f1-2e87-4e52-99d5-ace7c2a21dd7", "name": "load_p1rlv16177_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbbe8401-53a1-4ce7-9ce1-02f547055d95"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "11f69efc-00f8-446d-a326-f00471de567f"}}}}, {"uuid": "7db3fc2b-717d-425d-8ce2-4c368ad8a20a", "name": "31da6973-780b-499b-be21-8c61b7e98b6c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.060834559711965, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4528637167980347, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1ff20224-d53d-4d70-9fc9-a1f7ebf9208d", "name": "0ec4d3cb-1481-450d-b00b-af279a4ef278", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7db3fc2b-717d-425d-8ce2-4c368ad8a20a"}}}]}, {"uuid": "28082638-16ec-4f1c-8f35-73032dfe4ae6", "name": "load_p1rlv16178_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "807b0bef-0d34-44a9-a2a9-0c0a11f4ea8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1ff20224-d53d-4d70-9fc9-a1f7ebf9208d"}}}}, {"uuid": "811f9d5d-2c38-4000-ad90-2407c8ba381b", "name": "2ef15f6f-7918-40d9-b6ca-cc29041b0dbd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.060834559711965, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4528637167980347, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2a3acf25-d5eb-4013-b4a4-c3ae643867c7", "name": "ea4bf838-2578-43ad-adbb-7653cfafd7e0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "811f9d5d-2c38-4000-ad90-2407c8ba381b"}}}]}, {"uuid": "ecac8be1-ae8c-4ff3-a56b-ef59dff62e08", "name": "load_p1rlv16178_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "807b0bef-0d34-44a9-a2a9-0c0a11f4ea8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2a3acf25-d5eb-4013-b4a4-c3ae643867c7"}}}}, {"uuid": "cd990560-ccf7-4e47-b0a8-e54eaf37e8dd", "name": "9b055f05-34e8-4444-b73c-ac788fd443a8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8288850538480296, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31695217299610473, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b66da1a3-044a-46d1-bc15-fd8daeca6076", "name": "9d20ad51-c6df-4719-bbb3-fc460d08236b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cd990560-ccf7-4e47-b0a8-e54eaf37e8dd"}}}]}, {"uuid": "bb67aa8e-9868-4bb1-8164-10d1048423fa", "name": "load_p1rlv16197_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "92a37082-36d4-4eca-95e4-88dbcacd6db5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b66da1a3-044a-46d1-bc15-fd8daeca6076"}}}}, {"uuid": "9f6bbe6b-f152-41c4-9e9b-b4c8e195801f", "name": "24cc580e-f578-4485-b2b0-0fd8d9984bc2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8288850538480296, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31695217299610473, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2fac40fd-4c72-4eab-a08a-7602d5b740a2", "name": "77a10d6c-ca60-44f0-b5b2-ce72b05c0f2d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9f6bbe6b-f152-41c4-9e9b-b4c8e195801f"}}}]}, {"uuid": "61115f7b-14ea-43b1-98ab-6a4501c7e755", "name": "load_p1rlv16197_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "92a37082-36d4-4eca-95e4-88dbcacd6db5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2fac40fd-4c72-4eab-a08a-7602d5b740a2"}}}}, {"uuid": "51f2c6a7-abf8-40e1-b63a-5de2319c2e2e", "name": "8b4c8e30-f340-4d25-b10e-33fb7f7905c5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5775901800387742, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6237657200291109, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "597b73a2-1034-487f-99c0-2d74dc99d141", "name": "887f0fd4-281b-4a24-8373-82d40fd5bab5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "51f2c6a7-abf8-40e1-b63a-5de2319c2e2e"}}}]}, {"uuid": "fb695a11-0908-4b19-a9be-e8d1859b4c5c", "name": "load_p1rlv16200_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1aacea55-115d-46c3-9590-725cf5040f38"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "597b73a2-1034-487f-99c0-2d74dc99d141"}}}}, {"uuid": "e534beb3-a4d4-48f8-a6e7-7359ec2f1afe", "name": "a6e1477d-0917-4b47-9805-9ce404d0acf9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5775901800387742, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6237657200291109, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f8e68d22-1c77-4be7-ab6d-8b8d1a688b41", "name": "4b0eb596-282f-40d0-85d6-92ba67973883", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e534beb3-a4d4-48f8-a6e7-7359ec2f1afe"}}}]}, {"uuid": "188a1dbc-8092-4633-9710-6db102bbac68", "name": "load_p1rlv16200_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1aacea55-115d-46c3-9590-725cf5040f38"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f8e68d22-1c77-4be7-ab6d-8b8d1a688b41"}}}}, {"uuid": "d64fad99-5581-447e-a562-7368e6df2f92", "name": "925da18f-b233-4144-a409-1b24377fec95_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4950137537296666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31506625700854357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c1a632ee-3fca-43e2-a0b4-e237df300bec", "name": "e5fd1e11-75bd-45cf-8120-169d18ecd45b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d64fad99-5581-447e-a562-7368e6df2f92"}}}]}, {"uuid": "8113cfc0-7014-447a-aa9a-a78e4b9a2255", "name": "load_p1rlv16201_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68aa5cc5-f6bf-4417-8653-747c56b37b5e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c1a632ee-3fca-43e2-a0b4-e237df300bec"}}}}, {"uuid": "a0016079-70b3-4a6d-a640-8c3b1e6f6366", "name": "051018c9-0438-41c2-aad2-042ec84613e5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4950137537296666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31506625700854357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "690ba879-c2fe-4b7d-bf13-de4c8ff82366", "name": "eb8acc83-e967-44f1-97f1-480a94e04f1a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a0016079-70b3-4a6d-a640-8c3b1e6f6366"}}}]}, {"uuid": "1a299d11-654b-42f2-9549-0e1ebc5bfee8", "name": "load_p1rlv16201_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68aa5cc5-f6bf-4417-8653-747c56b37b5e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "690ba879-c2fe-4b7d-bf13-de4c8ff82366"}}}}, {"uuid": "82f80507-7e59-4d25-92e4-063d5352e131", "name": "2b930e05-b5ca-4776-b53c-2e93994c5ae3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.668048225868244, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.178282395400973, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "44a99c88-77f8-4547-a76c-e4cd0ceb5057", "name": "6a5b1ff0-2a62-4dae-b3c2-3f72552aaf24", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "82f80507-7e59-4d25-92e4-063d5352e131"}}}]}, {"uuid": "4e5070b5-da69-4033-a231-1ac0d07dd50f", "name": "load_p1rlv16206_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ca42395-8d67-4e83-80ec-159cacb490f8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "44a99c88-77f8-4547-a76c-e4cd0ceb5057"}}}}, {"uuid": "10efa989-c321-4627-b3ea-58a01ecb6c67", "name": "3087cff4-d666-4dc9-983f-07818d2217b4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.668048225868244, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.178282395400973, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6171b61a-c649-477b-b369-585b3d4f9d67", "name": "fcfee667-3a76-4915-a802-ec7625d41b65", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "10efa989-c321-4627-b3ea-58a01ecb6c67"}}}]}, {"uuid": "e6be7fda-f439-4963-ac3f-0d593ded7427", "name": "load_p1rlv16206_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ca42395-8d67-4e83-80ec-159cacb490f8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6171b61a-c649-477b-b369-585b3d4f9d67"}}}}, {"uuid": "6e3a2dd8-9d14-4656-97e1-29404e1858ed", "name": "db2f9d9c-7cc0-48af-b2fa-b337078e7f43_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8202631342288826, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.26720803692022926, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4ca4a8b8-2848-4562-84e4-b3091cabb297", "name": "a05549c7-64ca-4f21-8d1c-9ff1b5cf4180", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6e3a2dd8-9d14-4656-97e1-29404e1858ed"}}}]}, {"uuid": "38baae80-9e2b-4574-b0b8-80c9191778ea", "name": "load_p1rlv16209_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf413742-18c8-483d-b8f1-f125f95323da"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4ca4a8b8-2848-4562-84e4-b3091cabb297"}}}}, {"uuid": "0a051704-0824-4b50-9da2-9a88776bbf00", "name": "00f42130-c93c-426a-8da9-b9e3b3889a1a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8202631342288826, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.26720803692022926, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5072fd2e-6a5d-4f41-94d4-f4b07524235e", "name": "d5b24dcc-7afd-4cb1-a5ef-103b1cf30946", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0a051704-0824-4b50-9da2-9a88776bbf00"}}}]}, {"uuid": "4506020b-9977-4001-b008-07eb54d22c69", "name": "load_p1rlv16209_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf413742-18c8-483d-b8f1-f125f95323da"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5072fd2e-6a5d-4f41-94d4-f4b07524235e"}}}}, {"uuid": "f9622ad8-9c05-4623-94d2-fc3db1729d57", "name": "7ac7b347-6227-4658-8a0e-8d53c99901eb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.621947646480353, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0332384495271123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fa3d3118-0271-46bd-a8fc-ea328754fe18", "name": "cd84c6d0-7df2-4a20-845b-24648ee492c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f9622ad8-9c05-4623-94d2-fc3db1729d57"}}}]}, {"uuid": "da1537bc-3902-43ab-92af-239cf99fac5e", "name": "load_p1rlv16210_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fd05f3c-df77-45bc-8686-458b681a3d08"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fa3d3118-0271-46bd-a8fc-ea328754fe18"}}}}, {"uuid": "73b43497-48f7-4318-bc2b-74717054e651", "name": "2ef7c5ad-edd9-4aea-b435-2de079dea7a2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.621947646480353, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0332384495271123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f7675120-31a6-41cd-a416-bfe9e9b58a99", "name": "7c507e19-95e4-471d-8f33-0ca7d1770368", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "73b43497-48f7-4318-bc2b-74717054e651"}}}]}, {"uuid": "a85789d2-5bdf-40c4-8db0-32a010ac2bb9", "name": "load_p1rlv16210_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fd05f3c-df77-45bc-8686-458b681a3d08"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f7675120-31a6-41cd-a416-bfe9e9b58a99"}}}}, {"uuid": "bd71cb50-0006-42e9-ad81-75ecd8b79a48", "name": "f3080d62-ac16-4d83-8083-e140467ac72e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.08053934867757, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.19082517830123075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b64a5f67-da86-43f2-98ed-6d4f37fc6df6", "name": "9d0be648-054f-4b89-81b6-d49caf009d06", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bd71cb50-0006-42e9-ad81-75ecd8b79a48"}}}]}, {"uuid": "687d59e4-ec09-42fa-8290-945ee573225e", "name": "load_p1rlv16221_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9761003-33fa-482a-967b-b508ab67c19f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b64a5f67-da86-43f2-98ed-6d4f37fc6df6"}}}}, {"uuid": "c92936ad-112a-42cf-a795-6beca08af2e6", "name": "90c9377d-b6c7-4142-bdcc-518269e98dc2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.08053934867757, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.19082517830123075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "248dedcd-95bc-4a77-8661-b69cae451e77", "name": "27753590-42a1-496c-a0eb-79e1a17dd545", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c92936ad-112a-42cf-a795-6beca08af2e6"}}}]}, {"uuid": "25e15c21-5534-423f-b539-7fcdee678078", "name": "load_p1rlv16221_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9761003-33fa-482a-967b-b508ab67c19f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "248dedcd-95bc-4a77-8661-b69cae451e77"}}}}, {"uuid": "2e3a56f0-26d6-49c4-8278-48212669b3a8", "name": "a2b6d15a-95b2-48e7-9736-fea5cb3cf4d2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.0707881481560175, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.1283140369898392, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7d012a1d-6742-41dd-88a6-1cf39c22a3ff", "name": "86520804-049f-4fb5-8729-020319b66c13", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2e3a56f0-26d6-49c4-8278-48212669b3a8"}}}]}, {"uuid": "63aab616-7791-487d-a08b-51972220df8a", "name": "load_p1rlv16222_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4809afc1-2d3d-491d-80e5-9cd4e8da08f2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7d012a1d-6742-41dd-88a6-1cf39c22a3ff"}}}}, {"uuid": "f8befad7-db52-4f5b-bf30-4ec36de002d5", "name": "52968539-b947-42a1-b6e9-cad8ddf1b9e4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.0707881481560175, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.1283140369898392, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bf537ed1-e312-40d7-9588-585e4082e6de", "name": "eeab61f2-224c-4641-98d5-f33d205fe2bf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8befad7-db52-4f5b-bf30-4ec36de002d5"}}}]}, {"uuid": "9dc56401-aa82-4081-871e-dba02af9eb1d", "name": "load_p1rlv16222_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4809afc1-2d3d-491d-80e5-9cd4e8da08f2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bf537ed1-e312-40d7-9588-585e4082e6de"}}}}, {"uuid": "6d324efc-b032-4759-9496-6fcc6bf9f013", "name": "6730beef-de2e-4ef5-8580-c2053e941b70_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7997673490012955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.772957044307952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e7aef740-a876-4527-8c3a-81de3fb33468", "name": "e3c53125-15b6-4022-929c-1aade13ba79e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6d324efc-b032-4759-9496-6fcc6bf9f013"}}}]}, {"uuid": "1dd65483-4544-46ca-87b9-86004f8af419", "name": "load_p1rlv16228_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8767650-39c5-4d4a-80ce-af408c246599"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e7aef740-a876-4527-8c3a-81de3fb33468"}}}}, {"uuid": "08768275-2e22-4df1-8fcf-f8786fd610ab", "name": "75ed1a21-6584-4154-8564-29660d44dd60_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7997673490012955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.772957044307952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "86278f7c-6d66-40a6-9db0-49a2cb509a8a", "name": "017f4552-9fda-4e60-a865-b73ac6f60513", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "08768275-2e22-4df1-8fcf-f8786fd610ab"}}}]}, {"uuid": "23331b8c-8dbd-41bb-96e7-4a9ee02aa8ce", "name": "load_p1rlv16228_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8767650-39c5-4d4a-80ce-af408c246599"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "86278f7c-6d66-40a6-9db0-49a2cb509a8a"}}}}, {"uuid": "2384208f-c3da-4a5f-8774-5ed0b42d1775", "name": "9fb213e2-f60e-45b8-9dec-810063737f0f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.941898785419248, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8498359578625553, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d033bc93-d36e-4320-b499-6180fc5e3379", "name": "6ed32a0e-dbac-4c67-90da-a12fae14e1c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2384208f-c3da-4a5f-8774-5ed0b42d1775"}}}]}, {"uuid": "90c28d38-88fc-4f21-a316-fcf16d1a1721", "name": "load_p1rlv16235_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56b91b3f-dfdd-41bf-9d2e-a8183077c752"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d033bc93-d36e-4320-b499-6180fc5e3379"}}}}, {"uuid": "8ef99890-745e-4393-8325-fb5aa64640bc", "name": "cfc09689-4a41-4315-af0c-0f9e1c456e86_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.941898785419248, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8498359578625553, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "925e289d-82ac-4ac3-8e06-044ce8c912dc", "name": "c19e020c-bc6d-4120-b46a-4ab23c053afc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ef99890-745e-4393-8325-fb5aa64640bc"}}}]}, {"uuid": "f7a053ff-c115-476d-8880-bde065bababd", "name": "load_p1rlv16235_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56b91b3f-dfdd-41bf-9d2e-a8183077c752"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "925e289d-82ac-4ac3-8e06-044ce8c912dc"}}}}, {"uuid": "25e3363b-55dd-43a6-aa7c-52a7119bfeea", "name": "17149634-af64-479f-b5a7-cb5c71a5e4ed_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.992945339168608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.937847717707562, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "208c43d1-94a0-4344-90df-52dc7bd511d7", "name": "d6af770d-529f-4890-9352-0930b950bbb3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "25e3363b-55dd-43a6-aa7c-52a7119bfeea"}}}]}, {"uuid": "02061d0f-f540-4f78-aa26-193fbcf05a3c", "name": "load_p1rlv16239_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9642fa30-e5f7-42f1-8fda-ab75a265d25a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "208c43d1-94a0-4344-90df-52dc7bd511d7"}}}}, {"uuid": "87ba6520-cd25-4ef3-ac5b-39ccf50910aa", "name": "4e13ba8f-b575-487a-8493-6579b0d9c471_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.992945339168608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.937847717707562, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "00d96727-8577-4bde-9d0d-28049794d64a", "name": "47aeb06f-b5f7-464f-b4ff-c4d59927eb8f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "87ba6520-cd25-4ef3-ac5b-39ccf50910aa"}}}]}, {"uuid": "f591e871-f291-4273-b6bb-54f9144cd7f4", "name": "load_p1rlv16239_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9642fa30-e5f7-42f1-8fda-ab75a265d25a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "00d96727-8577-4bde-9d0d-28049794d64a"}}}}, {"uuid": "46676f65-412e-48ff-9fb8-53394bd9f99a", "name": "91b27021-aa12-45e7-aa70-f6bc9731a5b4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9337862827800336, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34425772205755256, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "415a56cf-38ae-4744-89b4-1e397956b57e", "name": "cf8aa6d7-3d6f-4c32-97a6-8b10840f41ba", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "46676f65-412e-48ff-9fb8-53394bd9f99a"}}}]}, {"uuid": "807b2c7b-8421-4be2-9991-525a59224a3a", "name": "load_p1rlv16242_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e82036d9-e6c8-42c3-b45b-30bef6902bbc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "415a56cf-38ae-4744-89b4-1e397956b57e"}}}}, {"uuid": "b8173146-9863-4a87-9624-704836c1d974", "name": "2907befd-8fc1-4310-b863-979de3223721_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9337862827800336, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34425772205755256, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cdd8a788-aa78-4ca7-9f7d-a5b151748276", "name": "fc5124bd-3d4c-4027-a48c-6b95c5adf4ee", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b8173146-9863-4a87-9624-704836c1d974"}}}]}, {"uuid": "c856e52e-6577-42dc-b16d-98eb2b4ba2d7", "name": "load_p1rlv16242_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e82036d9-e6c8-42c3-b45b-30bef6902bbc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cdd8a788-aa78-4ca7-9f7d-a5b151748276"}}}}, {"uuid": "bb93cf86-abd1-416e-9d9a-a6c9bd1ce715", "name": "ad19cd3b-2575-4a5b-b842-a965054e127a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7430249960912554, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9646854683366036, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7c4fa019-913f-42d9-8487-43baf7140118", "name": "85a9a0cd-f507-4cdf-9c94-9642caedde3c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bb93cf86-abd1-416e-9d9a-a6c9bd1ce715"}}}]}, {"uuid": "34c8cbbb-410b-4176-b515-fc86aa512951", "name": "load_p1rlv16243_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20818cc7-617e-4ab7-8f7c-31eea6496a02"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7c4fa019-913f-42d9-8487-43baf7140118"}}}}, {"uuid": "3d681fe6-c130-41b9-b824-051414bea0ef", "name": "b35ab247-2792-4051-a8cd-d1379991b7b5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7430249960912554, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9646854683366036, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c0caf009-8d97-4ccf-a18e-1c4744b66c66", "name": "7fa22bc4-e544-4985-8c30-952326b87d83", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3d681fe6-c130-41b9-b824-051414bea0ef"}}}]}, {"uuid": "067e83ef-33c4-4d7e-b6d2-b897ea32998f", "name": "load_p1rlv16243_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20818cc7-617e-4ab7-8f7c-31eea6496a02"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c0caf009-8d97-4ccf-a18e-1c4744b66c66"}}}}, {"uuid": "bbb7d194-ee30-4c7e-82bf-d6a343c5c099", "name": "c973ef57-4bea-4bf2-a02f-0b9f74f561b2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2766983969851713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5028612878254624, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0be0b900-102a-4d59-842e-2b164d4f82a4", "name": "02e72792-8785-464d-b508-fbbd4ee69536", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bbb7d194-ee30-4c7e-82bf-d6a343c5c099"}}}]}, {"uuid": "13aefa76-b966-4fcc-8857-ad70e07e674b", "name": "load_p1rlv16244_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0164339-acc1-4b95-aa31-3af42cf943f7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0be0b900-102a-4d59-842e-2b164d4f82a4"}}}}, {"uuid": "a78da743-46a7-4c08-a8e1-ceaf896565d8", "name": "ae676b84-86dd-4afa-a0a7-51a4b2fba285_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2766983969851713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5028612878254624, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a629ed77-26cc-4809-8503-c28eae2996f2", "name": "78479dde-0af5-487b-83df-a28f1a9a92fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a78da743-46a7-4c08-a8e1-ceaf896565d8"}}}]}, {"uuid": "fc7bdb18-05b5-4508-89cf-6b2d0be753ae", "name": "load_p1rlv16244_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0164339-acc1-4b95-aa31-3af42cf943f7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a629ed77-26cc-4809-8503-c28eae2996f2"}}}}, {"uuid": "49f92419-0d54-443b-8d43-33d0b1876020", "name": "26f20116-38be-47a3-a72d-30669c1a648e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.13715702476687, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3795210711832634, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6f4efc49-d644-487e-9eff-4333bb378c29", "name": "99f989f4-5b24-45b4-9f1b-0e1a29073b7f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "49f92419-0d54-443b-8d43-33d0b1876020"}}}]}, {"uuid": "79fe76ff-6ba6-465f-95d8-8a6c22d2ab39", "name": "load_p1rlv16245_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3783c838-b72e-42cd-8b0b-3005bca3cf5e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6f4efc49-d644-487e-9eff-4333bb378c29"}}}}, {"uuid": "009fce19-1ad7-46eb-a6a7-2de897f44fe7", "name": "7a433bcd-05e4-4262-b28a-b0dccca99d3e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.13715702476687, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3795210711832634, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b117b8fd-198c-4662-b556-190230cca40b", "name": "fbdb871d-ac90-4986-afb4-98f9f3c46423", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "009fce19-1ad7-46eb-a6a7-2de897f44fe7"}}}]}, {"uuid": "3a382cd8-e1bc-4c1b-9592-198db8d95239", "name": "load_p1rlv16245_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3783c838-b72e-42cd-8b0b-3005bca3cf5e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b117b8fd-198c-4662-b556-190230cca40b"}}}}, {"uuid": "c2a99cd4-f825-458d-884c-65bedb2d91ce", "name": "bb10f447-0dd9-47bb-9b43-bb2438d3ad0c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.133603663599094, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7fbeaf93-c0a2-41e2-93c1-81d2463975fc", "name": "4d94c9b3-5a90-493c-a165-f922cec9ba41", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c2a99cd4-f825-458d-884c-65bedb2d91ce"}}}]}, {"uuid": "cc498e82-9ab9-40a7-b1e3-362b034829b2", "name": "load_p1rlv16246_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd2dc2db-787a-4732-bae4-01186082a92d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7fbeaf93-c0a2-41e2-93c1-81d2463975fc"}}}}, {"uuid": "8fd4c161-fb13-4a88-ad9f-6d89a71bc353", "name": "7c4bb292-324f-44f6-ab57-7d5ef8525060_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.133603663599094, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6b2cf3bb-66d6-44aa-9f18-3339fa5074de", "name": "8e4d0312-8875-4ed0-bf5e-94b2e7461be0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8fd4c161-fb13-4a88-ad9f-6d89a71bc353"}}}]}, {"uuid": "3d44bacf-37ae-4eeb-9ec0-31965edfded3", "name": "load_p1rlv16246_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd2dc2db-787a-4732-bae4-01186082a92d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6b2cf3bb-66d6-44aa-9f18-3339fa5074de"}}}}, {"uuid": "4d5e82c2-d868-4b53-a073-007053cd037b", "name": "20d0f761-6902-4647-9a0e-5e6c1c69413f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0472938281946713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.40441110210881914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "03eef06c-dfb2-4e26-80eb-b44907416c52", "name": "7b959a9f-b5f7-4d58-aebb-ee74e4f8b29b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4d5e82c2-d868-4b53-a073-007053cd037b"}}}]}, {"uuid": "f2fe1b05-e077-42ca-8efb-c10275765edd", "name": "load_p1rlv16247_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8d5e9b7-dc95-41f9-8547-99d5e2eba874"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "03eef06c-dfb2-4e26-80eb-b44907416c52"}}}}, {"uuid": "b1b47682-7ade-48a9-9a13-7e549a05e897", "name": "11ad2d15-c8ad-4963-8a08-54201a231804_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0472938281946713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.40441110210881914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6e7104d0-2c2d-41a3-9fb8-9d72be0b0dcc", "name": "c0a8c15a-8ba9-44ac-98c5-b3d045ad36dc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b1b47682-7ade-48a9-9a13-7e549a05e897"}}}]}, {"uuid": "8111a614-f55e-4424-8ee4-434bbcae8351", "name": "load_p1rlv16247_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8d5e9b7-dc95-41f9-8547-99d5e2eba874"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6e7104d0-2c2d-41a3-9fb8-9d72be0b0dcc"}}}}, {"uuid": "9ff37076-e004-4425-a80c-3d3d8c99522d", "name": "2549db86-05ca-4352-bb29-e32892d23a92_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.398785600945231, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1157218527290627, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4613a88c-f171-4465-bc15-c79e9df82900", "name": "0c625c40-07ce-44eb-9850-e9eb6a7c6ba8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9ff37076-e004-4425-a80c-3d3d8c99522d"}}}]}, {"uuid": "9d5ffda1-a68b-4bd1-85eb-2989a2b9fb13", "name": "load_p1rlv16248_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "feb24768-feab-40f0-acc3-0b2bb500133a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4613a88c-f171-4465-bc15-c79e9df82900"}}}}, {"uuid": "0a7dc028-61ac-49b0-9e30-18f48a26ad17", "name": "807c8942-2d0d-455f-afc7-13dfc93159de_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.398785600945231, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1157218527290627, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "28bb9324-fb40-438d-a836-6880409cf4f9", "name": "fbc6768a-8fd6-4b85-a6be-605f380e2b45", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0a7dc028-61ac-49b0-9e30-18f48a26ad17"}}}]}, {"uuid": "8485dd6a-1c4a-49e3-803f-5635ffbe888b", "name": "load_p1rlv16248_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "feb24768-feab-40f0-acc3-0b2bb500133a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "28bb9324-fb40-438d-a836-6880409cf4f9"}}}}, {"uuid": "cdb85435-3309-47db-acb8-3a4839a89c95", "name": "8c0a59e0-937c-4bfb-bf0a-c0e84b341307_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c8744706-ab22-439f-abb2-6e1d0a500e5e", "name": "66c41bf8-3865-446e-a90b-1d5888d1f614", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cdb85435-3309-47db-acb8-3a4839a89c95"}}}]}, {"uuid": "ce7419eb-0876-4a0d-b3d2-2e8cc904a6ea", "name": "load_p1rlv16252_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5c6a5f39-0654-4e73-8050-c6c4ad9d54e6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c8744706-ab22-439f-abb2-6e1d0a500e5e"}}}}, {"uuid": "e477f4cc-f400-4b29-89ac-275cfab6836f", "name": "df8251ad-abb0-4b52-b0c6-32bcf56fc79f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3b142e78-a993-450e-84ba-90be31f9ed69", "name": "1312c866-677e-447c-9620-99ea07dd6e0e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e477f4cc-f400-4b29-89ac-275cfab6836f"}}}]}, {"uuid": "2350796d-9a55-42a8-9a85-fdefcd538274", "name": "load_p1rlv16252_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5c6a5f39-0654-4e73-8050-c6c4ad9d54e6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3b142e78-a993-450e-84ba-90be31f9ed69"}}}}, {"uuid": "e3b7d7a4-5f3a-41a4-b70a-5e0ec4999e4b", "name": "ee6b1bea-4ade-4e58-a2c1-0ea641f587d7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.430610855643826, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18457628630998096, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1db2a9f7-c324-4edd-9719-093ac13f48d1", "name": "0d069785-32ae-4270-b536-d1544147545c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e3b7d7a4-5f3a-41a4-b70a-5e0ec4999e4b"}}}]}, {"uuid": "33949412-5af7-4de0-9332-1bc2058e7b37", "name": "load_p1rlv16253_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "268549c6-0c8b-44ac-b933-316b36645366"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1db2a9f7-c324-4edd-9719-093ac13f48d1"}}}}, {"uuid": "53cc9afa-9837-48ce-923f-20253d4fbcf7", "name": "6f33ad52-125d-41ed-b940-d62e20895233_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.430610855643826, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18457628630998096, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9ba7469e-8d1d-4dd6-9195-589e6a163b26", "name": "e7513ceb-a589-46a9-97f8-ad86a84e318a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "53cc9afa-9837-48ce-923f-20253d4fbcf7"}}}]}, {"uuid": "74f69ee4-622b-4963-9559-731cd64ccc6a", "name": "load_p1rlv16253_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "268549c6-0c8b-44ac-b933-316b36645366"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9ba7469e-8d1d-4dd6-9195-589e6a163b26"}}}}, {"uuid": "03ab610d-cdc2-4e3e-9333-3355d230c63e", "name": "c4ca1ade-179d-432e-83aa-2c08fc697d4d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4644531671008476, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4817339405405778, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "73bc9f62-480f-46cf-afcd-8c5b94b12949", "name": "7a7f61eb-ff66-4592-b711-e8f68fb6f976", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "03ab610d-cdc2-4e3e-9333-3355d230c63e"}}}]}, {"uuid": "30737f1f-4319-4ba3-b143-efc491f42666", "name": "load_p1rlv16255_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04647fad-19dc-4ed8-8820-aa312674145c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "73bc9f62-480f-46cf-afcd-8c5b94b12949"}}}}, {"uuid": "4b23e311-7943-422d-8036-795d226c5056", "name": "4c2b9662-225b-4476-a820-ebea7dd6cd13_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4644531671008476, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4817339405405778, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9abfb742-8cbc-45c7-9c87-4371f7aaccb0", "name": "15e086d0-210c-410b-8705-47d18a32229a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4b23e311-7943-422d-8036-795d226c5056"}}}]}, {"uuid": "ed5cb148-e823-4091-ada6-468a35548c2b", "name": "load_p1rlv16255_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04647fad-19dc-4ed8-8820-aa312674145c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9abfb742-8cbc-45c7-9c87-4371f7aaccb0"}}}}, {"uuid": "b9206117-0529-4264-b73e-55b2500c05e3", "name": "ab5cd4c7-7ee7-4c21-8057-038063eaf9e2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8706127135667018, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16715860689265086, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5ea928af-bad6-4091-8dc7-75ba862f7511", "name": "bec19463-4229-4d6e-b63c-15a0450d2b4c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b9206117-0529-4264-b73e-55b2500c05e3"}}}]}, {"uuid": "7ef08658-1307-4121-8016-74f46feb38bd", "name": "load_p1rlv16256_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32a9302f-2d40-4c2a-bde9-e4039694fed7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5ea928af-bad6-4091-8dc7-75ba862f7511"}}}}, {"uuid": "4400e645-c15b-423d-a001-1fafe395d053", "name": "f9fdfbe0-2bf8-4b72-a366-e3da05e258ae_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8706127135667018, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16715860689265086, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dda8c1a5-525e-4364-af26-78e19424f467", "name": "d63cdbd6-502d-4681-99e2-a8eeb953b257", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4400e645-c15b-423d-a001-1fafe395d053"}}}]}, {"uuid": "cdeb8b48-47ad-4bf8-92c3-0363ebc6a782", "name": "load_p1rlv16256_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32a9302f-2d40-4c2a-bde9-e4039694fed7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dda8c1a5-525e-4364-af26-78e19424f467"}}}}, {"uuid": "beac4282-b4c7-4eb0-93de-2a41be630a43", "name": "925a2eb7-b2e0-46cc-b80b-bf4f2b8a93d5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5300176124233262, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6781680527999017, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d502673e-7dd3-45a6-a579-ffb9a55848f8", "name": "01ef29b7-8ff1-4800-936c-664779c361a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "beac4282-b4c7-4eb0-93de-2a41be630a43"}}}]}, {"uuid": "d28047d9-c03a-4972-8fc7-efa3a0ce86d9", "name": "load_p1rlv16257_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "935c99a6-bef6-4417-872c-0685011c440c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d502673e-7dd3-45a6-a579-ffb9a55848f8"}}}}, {"uuid": "994e5651-413a-4b97-a2b2-d5943a71cb58", "name": "828072ef-0a9d-4974-829c-5645d4bedae7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5300176124233262, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6781680527999017, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7ba5b6f2-9cab-41b0-a932-9d854bd3325b", "name": "a8b422ff-9d3e-4557-bdcd-773a89766f6f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "994e5651-413a-4b97-a2b2-d5943a71cb58"}}}]}, {"uuid": "2ba63650-a710-4e26-a30d-86e871c82e66", "name": "load_p1rlv16257_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "935c99a6-bef6-4417-872c-0685011c440c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7ba5b6f2-9cab-41b0-a932-9d854bd3325b"}}}}, {"uuid": "2f6b96cc-4721-4475-95e9-eaa8a0e85f03", "name": "63625f2b-020f-4476-9e1c-9d712ccdd87d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6722127407962883, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033140171384262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "811a9b5d-2a61-4b6c-a2e0-5ce107bc00b6", "name": "73230dbd-3733-4264-9aa6-d13e34b20755", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2f6b96cc-4721-4475-95e9-eaa8a0e85f03"}}}]}, {"uuid": "52ab00f6-292c-455d-bbba-80c1f0b5f91b", "name": "load_p1rlv16260_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdf35585-e2b3-4463-a6a8-acb352f25003"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "811a9b5d-2a61-4b6c-a2e0-5ce107bc00b6"}}}}, {"uuid": "c15b2547-d011-4db6-9d04-f1e717f0f08c", "name": "54f7a169-8b0d-47b2-8b14-27e16b6a261d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6722127407962883, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033140171384262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1af14652-b203-4f34-9074-6cdb51a10016", "name": "e9a088d2-69ef-4170-877b-8920df6b8e71", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c15b2547-d011-4db6-9d04-f1e717f0f08c"}}}]}, {"uuid": "2d908939-4308-4f5b-be72-53cc9f4d1d1e", "name": "load_p1rlv16260_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdf35585-e2b3-4463-a6a8-acb352f25003"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1af14652-b203-4f34-9074-6cdb51a10016"}}}}, {"uuid": "cc7c06ce-5557-4741-adbd-bc87cfa866a0", "name": "bb5a6a11-424e-401c-afe5-bd05c2743423_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2418080165747822, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43915934621283365, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e320a0b7-fe42-471c-8a89-4b6bdc6b5d40", "name": "362883ee-229b-4629-a632-6584f97529e5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cc7c06ce-5557-4741-adbd-bc87cfa866a0"}}}]}, {"uuid": "6842b389-cbce-4f73-840a-cc799b7336fa", "name": "load_p1rlv16261_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "978533ca-ef57-4cb6-9e7f-b3c6d1bbd7d5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e320a0b7-fe42-471c-8a89-4b6bdc6b5d40"}}}}, {"uuid": "f808bfb1-0f63-49a6-b4d7-84c408cf8403", "name": "2a7b63c6-3aa6-455e-acdc-a90973682fd4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2418080165747822, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43915934621283365, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "76000378-abb6-474c-b2ef-c9a5911ca0e0", "name": "0df3c89f-82a2-4420-9285-06a1a22b331f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f808bfb1-0f63-49a6-b4d7-84c408cf8403"}}}]}, {"uuid": "da0c47c7-3c79-431b-a175-2dcfd601d834", "name": "load_p1rlv16261_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "978533ca-ef57-4cb6-9e7f-b3c6d1bbd7d5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "76000378-abb6-474c-b2ef-c9a5911ca0e0"}}}}, {"uuid": "63fe4f3f-90de-445b-8136-d4cdd933eed8", "name": "3cffff74-ca06-4e9a-9232-7d0df38f01a8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3461402320099836, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.810674183062217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "97783810-fe85-49f2-b7b1-4af46cbb2455", "name": "3c85ce4a-02e0-4569-9661-7e6e18d6fcc6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "63fe4f3f-90de-445b-8136-d4cdd933eed8"}}}]}, {"uuid": "2478ec7b-45fe-451f-96aa-9cd41b6f9263", "name": "load_p1rlv16262_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2797febc-f5e7-4cb3-b26f-ace990dc6920"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "97783810-fe85-49f2-b7b1-4af46cbb2455"}}}}, {"uuid": "b5bd882c-07e7-4870-a1b0-72e8c0a74c42", "name": "ca1173a9-81dd-4995-b2c8-8be9f00d3b44_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3461402320099836, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.810674183062217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ad7e9c8c-0ea3-4832-aaef-b9d7c92f3ba2", "name": "0ddc8173-4d7f-46b0-91fa-215a138b9994", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5bd882c-07e7-4870-a1b0-72e8c0a74c42"}}}]}, {"uuid": "6dbd4747-2e7a-43d5-82c0-b479ca86714f", "name": "load_p1rlv16262_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2797febc-f5e7-4cb3-b26f-ace990dc6920"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ad7e9c8c-0ea3-4832-aaef-b9d7c92f3ba2"}}}}, {"uuid": "766c6dc0-d413-4dbb-a420-6b1533031cf2", "name": "7fb9e6ab-e824-4df2-a9cb-5005dcccf9b0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0052757727111112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4127143879372469, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9c4de1e6-0bd5-48b5-be95-30f7a4348c4a", "name": "a7c4d71c-995e-451f-a474-d0549dc2595b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "766c6dc0-d413-4dbb-a420-6b1533031cf2"}}}]}, {"uuid": "0219d6c8-98f6-4b98-ba29-a7464b82d3a0", "name": "load_p1rlv16266_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8835446-b333-4be9-96bd-57ff9d01ebd3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9c4de1e6-0bd5-48b5-be95-30f7a4348c4a"}}}}, {"uuid": "6dd6e2aa-1372-49e8-b910-cfe96b05329f", "name": "83b3b560-4487-470e-949c-4bba6d48ced2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0052757727111112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4127143879372469, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bfa003ca-bc4f-40f9-86c4-6a26450c4ff9", "name": "53a515c2-8ea2-459f-bea2-aca4afe2b4cc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6dd6e2aa-1372-49e8-b910-cfe96b05329f"}}}]}, {"uuid": "c786b4c3-1774-4050-8f6c-dc85c54dcd2e", "name": "load_p1rlv16266_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8835446-b333-4be9-96bd-57ff9d01ebd3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bfa003ca-bc4f-40f9-86c4-6a26450c4ff9"}}}}, {"uuid": "ac644023-aa22-402b-ace4-4f36a5673237", "name": "e670b296-ded9-440d-ab06-b3f8559514b0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.794005533851084, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6855099409421886, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "34c86588-a163-48ef-b08d-7eb6cef459c9", "name": "907ea48a-5646-4b42-92a1-dbb5541aa5db", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ac644023-aa22-402b-ace4-4f36a5673237"}}}]}, {"uuid": "499f83ff-6b0f-4a37-8418-a9a3cf315367", "name": "load_p1rlv16267_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19aeb510-ac0e-4279-8db0-8de282beccc8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "34c86588-a163-48ef-b08d-7eb6cef459c9"}}}}, {"uuid": "a80fc465-3c9d-438b-90e2-02ba863feea8", "name": "633da08d-3a5e-43ac-894b-3b2ccf0b86bf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.794005533851084, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6855099409421886, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "443427c2-6d12-4a22-b3d0-b408d981790a", "name": "17416c46-f23f-4b83-8ea4-a680905559b6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a80fc465-3c9d-438b-90e2-02ba863feea8"}}}]}, {"uuid": "127ee3f0-2b6f-46e0-953b-289dcd335a77", "name": "load_p1rlv16267_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19aeb510-ac0e-4279-8db0-8de282beccc8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "443427c2-6d12-4a22-b3d0-b408d981790a"}}}}, {"uuid": "fbe6e7b4-6025-4fac-b687-23e5575e10a1", "name": "44017a22-e3fc-440b-b8d4-7a098e0e770b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.996798907530164, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8717719006522443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a9e73675-bd7f-4896-a8ef-b46736678299", "name": "e6fc554d-c5a0-41bd-8cfc-9b4ea5d0a630", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fbe6e7b4-6025-4fac-b687-23e5575e10a1"}}}]}, {"uuid": "45761486-6e20-4090-94b4-f9d63478adc5", "name": "load_p1rlv16268_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba6ebe7f-b6b9-4f89-8bbf-7bffd63e10ef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a9e73675-bd7f-4896-a8ef-b46736678299"}}}}, {"uuid": "18caad4c-d890-448a-9ace-972ec6a6835f", "name": "5e667111-1000-4735-bc29-2f67e6a70057_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.996798907530164, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8717719006522443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dc1f1735-3f44-4f61-b875-f12cb02307da", "name": "a5de17ab-6886-4664-96b3-3b91edcb5728", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "18caad4c-d890-448a-9ace-972ec6a6835f"}}}]}, {"uuid": "ec9dbc63-2f0e-4689-9ab4-bc7d0fb48a81", "name": "load_p1rlv16268_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba6ebe7f-b6b9-4f89-8bbf-7bffd63e10ef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dc1f1735-3f44-4f61-b875-f12cb02307da"}}}}, {"uuid": "2bb55537-b3e1-4402-ae93-99f3cfc641a0", "name": "d8204634-e3fb-46cc-be88-bf688e8403ec_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.363798145332242, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4037116383567407, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "18b116f5-1ea8-404d-bac8-f2a3ef26b69b", "name": "f51befad-0132-4880-b571-049060304211", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2bb55537-b3e1-4402-ae93-99f3cfc641a0"}}}]}, {"uuid": "9bc29a80-f4ba-400b-b9d9-5db241d12b87", "name": "load_p1rlv16269_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc746539-662a-4fe4-8774-6ba2dc538118"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "18b116f5-1ea8-404d-bac8-f2a3ef26b69b"}}}}, {"uuid": "a9bcdd6a-962b-4507-947d-e42dd45d6fb1", "name": "90a80808-5225-4d5b-a3b3-22321a5f0a94_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.363798145332242, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4037116383567407, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d7b1fa47-0d96-46d5-b6cc-b9d9ecb31cec", "name": "f475d6a4-7e59-4bd1-a7d3-a45749669581", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a9bcdd6a-962b-4507-947d-e42dd45d6fb1"}}}]}, {"uuid": "4f175f3f-77a2-4b06-92d1-e3eae1b6a441", "name": "load_p1rlv16269_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc746539-662a-4fe4-8774-6ba2dc538118"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d7b1fa47-0d96-46d5-b6cc-b9d9ecb31cec"}}}}, {"uuid": "88028e8a-b39f-47f5-ae02-9827bed072f6", "name": "2a31ba10-cda3-4d2c-ad58-4118a881432a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.715296910036079, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.4546814180149177, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b8db8593-7b21-4054-b8b1-7e099912bdc2", "name": "89ed205c-4a38-46e9-afc3-163d886fe797", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "88028e8a-b39f-47f5-ae02-9827bed072f6"}}}]}, {"uuid": "858ffea9-e5e4-4ffc-9d42-b093f732e45a", "name": "load_p1rlv16270_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c620d4b9-a849-4bf6-b108-118836866602"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b8db8593-7b21-4054-b8b1-7e099912bdc2"}}}}, {"uuid": "4fb48713-2e5d-478a-8411-d43906004b3f", "name": "9fbcd029-fe06-4367-8b92-13840b382478_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.715296910036079, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.4546814180149177, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "453a6785-1ac8-404d-89d2-1428d14db38d", "name": "2ee690ab-de60-49c3-af76-f76b89005969", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4fb48713-2e5d-478a-8411-d43906004b3f"}}}]}, {"uuid": "ec15395f-4ea3-4a6d-92b1-88e1ec5f0d99", "name": "load_p1rlv16270_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c620d4b9-a849-4bf6-b108-118836866602"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "453a6785-1ac8-404d-89d2-1428d14db38d"}}}}, {"uuid": "5e911122-0db2-45dd-ac44-255e1ce2411c", "name": "03277084-12fe-4790-9668-fe8bb0eb03b1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.381399729703326, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.39528166539642545, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "32b235f2-0766-401f-8138-ad69dd2b6554", "name": "03277084-12fe-4790-9668-fe8bb0eb03b1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.381399729703326, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.39528166539642545, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fae6af08-41bc-4ece-913d-30dbceb3662d", "name": "03277084-12fe-4790-9668-fe8bb0eb03b1_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.381399729703326, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.39528166539642545, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "653f0d5d-08e0-47e1-a06d-715772f43c9d", "name": "8d7aafb3-8c0d-44f7-a78c-8cd67e83374a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5e911122-0db2-45dd-ac44-255e1ce2411c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "32b235f2-0766-401f-8138-ad69dd2b6554"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fae6af08-41bc-4ece-913d-30dbceb3662d"}}}]}, {"uuid": "d43dadee-e804-47c5-b631-82815e8ff5a5", "name": "load_p1rlv16271", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "606bf8f6-d745-4220-8cae-e01ffd22f669"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "653f0d5d-08e0-47e1-a06d-715772f43c9d"}}}}, {"uuid": "8ff3666a-1963-476c-b693-6e282e2a9e80", "name": "e2a47060-377d-427a-a38f-820686e5aa38_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.200687176070838, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9185981858680964, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f9123dcb-c7b3-422d-a8ea-8221e79caf63", "name": "0220b4c2-aa64-438f-ab3b-53e41f2f2d09", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ff3666a-1963-476c-b693-6e282e2a9e80"}}}]}, {"uuid": "031b5c59-2c52-4aec-8004-569f6c5a58d6", "name": "load_p1rlv16395_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d908890-4fe4-4349-92de-464c4165b185"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f9123dcb-c7b3-422d-a8ea-8221e79caf63"}}}}, {"uuid": "94238b3a-7fbf-4103-85a7-29eed43f218a", "name": "4e22a016-eb19-423a-bd1a-f2163e3af209_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.200687176070838, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9185981858680964, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "df08e771-7168-481a-ac9d-db1982a6beba", "name": "59f2bd06-7d04-442c-8ebd-4482658d2f47", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "94238b3a-7fbf-4103-85a7-29eed43f218a"}}}]}, {"uuid": "e193f5cd-04c5-410c-9bc1-24636b2ade55", "name": "load_p1rlv16395_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d908890-4fe4-4349-92de-464c4165b185"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "df08e771-7168-481a-ac9d-db1982a6beba"}}}}, {"uuid": "5e8f9a6c-45eb-41d2-a216-cdb7483ef44f", "name": "1566d76b-0145-466e-82c6-a75d0c430211_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.2106819008595595, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9283160881681002, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8c99023a-c460-4f29-b354-305ff8386f11", "name": "34e343f9-2dce-4c6f-9eea-d1134fa429fc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5e8f9a6c-45eb-41d2-a216-cdb7483ef44f"}}}]}, {"uuid": "78ba092a-6d63-42c4-9de8-782f0fe22265", "name": "load_p1rlv16397_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "323373a9-8e7d-4fb4-8970-dcc0e6d26c98"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8c99023a-c460-4f29-b354-305ff8386f11"}}}}, {"uuid": "63422d23-642b-4d3b-81af-4314d3fcd30a", "name": "7078de00-ecb8-4875-9964-76435221690b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.2106819008595595, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9283160881681002, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bb56652e-af5e-41f7-a9ee-946da3e3082c", "name": "98160b95-d28a-4371-a8da-a13f3b99df61", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "63422d23-642b-4d3b-81af-4314d3fcd30a"}}}]}, {"uuid": "fa96bddd-c21e-4501-99b6-78db3a2ca659", "name": "load_p1rlv16397_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "323373a9-8e7d-4fb4-8970-dcc0e6d26c98"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bb56652e-af5e-41f7-a9ee-946da3e3082c"}}}}, {"uuid": "e0b8d152-b240-434a-abe9-c4a70a2db003", "name": "38583533-e4ea-4249-8e7e-1c4ed998db82_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.920542613760824, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4990926315178331, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9e3961fc-f9f8-4891-951a-23e65d454092", "name": "a0ae2021-193a-4953-980f-f36acf97e0fd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e0b8d152-b240-434a-abe9-c4a70a2db003"}}}]}, {"uuid": "e4861e25-be6b-4ee7-8e99-6ede3986573d", "name": "load_p1rlv16401_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eeb598c2-f0b9-44df-bfaa-be66e4dc3920"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9e3961fc-f9f8-4891-951a-23e65d454092"}}}}, {"uuid": "3eb79a2e-5060-4dbc-9c72-5a4579c04793", "name": "5c536cf4-fa72-451d-be0d-a0e6fd1991be_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.920542613760824, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4990926315178331, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "895c87e5-e252-4913-a419-0644656b383d", "name": "62f3429e-8711-4c19-a7bb-3ce027f757a4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3eb79a2e-5060-4dbc-9c72-5a4579c04793"}}}]}, {"uuid": "a4fc401f-e024-44ee-bdbf-fce51a70f474", "name": "load_p1rlv16401_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eeb598c2-f0b9-44df-bfaa-be66e4dc3920"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "895c87e5-e252-4913-a419-0644656b383d"}}}}, {"uuid": "0cb39cce-8587-42be-8a63-ae3f59f5498a", "name": "eaf5cd82-120d-4055-93ae-a5c5fadd5609_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.747873943758341, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9398519580990949, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a7d066f-f450-4423-a697-67bfabe799b6", "name": "2e5625b0-4790-436b-8bf6-f13c9400d604", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0cb39cce-8587-42be-8a63-ae3f59f5498a"}}}]}, {"uuid": "972c7a59-6ae7-404e-81c7-fa45c57dfe21", "name": "load_p1rlv16412_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99f97a6b-4e94-4a35-ad00-12e7004ab5e3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0a7d066f-f450-4423-a697-67bfabe799b6"}}}}, {"uuid": "a8d982e1-2a2e-460e-883b-a181406ff941", "name": "9c75b838-e827-4110-a6bf-ef41c34de906_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.747873943758341, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9398519580990949, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dbaadde4-0d3c-44c0-b295-8e7e110e0148", "name": "1305a3ed-9851-45cb-8f23-09fdbd0d484b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a8d982e1-2a2e-460e-883b-a181406ff941"}}}]}, {"uuid": "71897fc9-f974-473a-8e44-b653f2d4c7c9", "name": "load_p1rlv16412_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99f97a6b-4e94-4a35-ad00-12e7004ab5e3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dbaadde4-0d3c-44c0-b295-8e7e110e0148"}}}}, {"uuid": "fb4a62a0-6b8b-4aa4-a292-412cd593e270", "name": "bd94fb3e-a911-4262-9c76-ea0664b61703_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9024769844937937, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4778358547008617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fd827a6d-018c-4b7a-bb2a-6ed130bd6e6e", "name": "59cdad1d-5b1e-4c9b-bfc1-512f9c41b5a2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fb4a62a0-6b8b-4aa4-a292-412cd593e270"}}}]}, {"uuid": "2ce8b856-2d26-4281-aaab-596c3aa921b1", "name": "load_p1rlv16416_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f58421d6-268b-417f-a579-c9c51d010697"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fd827a6d-018c-4b7a-bb2a-6ed130bd6e6e"}}}}, {"uuid": "39d86888-aaa7-4a94-b9ec-9444c822057c", "name": "c8dbd97e-f5f6-4daa-a313-2c40117c05c7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9024769844937937, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4778358547008617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "847117f1-9f81-41be-b42e-fd15caeb15e1", "name": "ef194679-6d04-4f0d-9bd6-d5cb958e0160", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "39d86888-aaa7-4a94-b9ec-9444c822057c"}}}]}, {"uuid": "144a5cf3-f2a4-499f-8c1d-a996c5975237", "name": "load_p1rlv16416_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f58421d6-268b-417f-a579-c9c51d010697"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "847117f1-9f81-41be-b42e-fd15caeb15e1"}}}}, {"uuid": "b5b3d6cf-cf26-41b1-92fa-2c00a700f522", "name": "e3c3d445-ec7d-4307-a035-29b44e2cffc9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.100297733607771, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.379845362785626, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "48234896-3c26-4383-bf9c-7bb1d6ccc698", "name": "d661ec93-2b74-4ca4-acae-c25a38675b40", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5b3d6cf-cf26-41b1-92fa-2c00a700f522"}}}]}, {"uuid": "50b75eea-371d-414e-84a7-a37d6213dc2f", "name": "load_p1rlv16422_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f367b63c-c4cb-4810-a270-8bd0153b7b32"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "48234896-3c26-4383-bf9c-7bb1d6ccc698"}}}}, {"uuid": "f76aa752-5d3c-4be3-8a2d-1fabc5243c2c", "name": "674f99af-8538-4b59-ab83-3a7769bc1e72_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.100297733607771, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.379845362785626, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7cfa42c3-e840-422f-80a5-74b8ec5dde7b", "name": "da5a56e2-0034-4629-8766-d31f5dbcf160", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f76aa752-5d3c-4be3-8a2d-1fabc5243c2c"}}}]}, {"uuid": "84ee1d2a-1808-4c42-b6ba-45fe48465d3e", "name": "load_p1rlv16422_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f367b63c-c4cb-4810-a270-8bd0153b7b32"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7cfa42c3-e840-422f-80a5-74b8ec5dde7b"}}}}, {"uuid": "acb00d95-db2f-40e8-beb1-a4e8a45da78d", "name": "b4cdad6e-5ab2-4a57-ab7e-e4f723888a64_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7146312183983485, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.11264482158049681, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "be571320-8f57-4664-9bb6-d56b2d52f5a2", "name": "13c3ce49-f12c-4cf8-bdad-35c19c524a2a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "acb00d95-db2f-40e8-beb1-a4e8a45da78d"}}}]}, {"uuid": "545bdbcc-1bb9-4d47-88c5-63387a19ba86", "name": "load_p1rlv16424_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2242f1c-542f-4c1f-b3e6-19482cccde8d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "be571320-8f57-4664-9bb6-d56b2d52f5a2"}}}}, {"uuid": "ddbcc4d0-063e-42c3-aed6-33dbcc9717b4", "name": "6301a0e2-3050-41f1-82f2-e9b469ea8890_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7146312183983485, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.11264482158049681, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "de5e16e3-2362-49da-8da5-dd4fab6e1d8f", "name": "a907226d-90ca-4a98-b898-33882224f3d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ddbcc4d0-063e-42c3-aed6-33dbcc9717b4"}}}]}, {"uuid": "ca76d76a-35c5-4ce5-bb21-a6c2111d97f8", "name": "load_p1rlv16424_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2242f1c-542f-4c1f-b3e6-19482cccde8d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "de5e16e3-2362-49da-8da5-dd4fab6e1d8f"}}}}, {"uuid": "0957b252-5e47-41f7-b6a2-e6577b17d3ce", "name": "bc925ba2-7d8a-4708-b132-5ece3fa00e87_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.793928923123666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.7667648924934154, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "60d2dcc2-e172-4041-abfb-5298882919e7", "name": "5d0b074a-5d1c-4241-a268-95c5b2571918", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0957b252-5e47-41f7-b6a2-e6577b17d3ce"}}}]}, {"uuid": "ed7f906d-4b9f-4f83-8d0a-58f61acbdb93", "name": "load_p1rlv16445_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e090544-3c8e-4716-9dae-0b311a1017ea"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "60d2dcc2-e172-4041-abfb-5298882919e7"}}}}, {"uuid": "883d160b-99e7-4ffd-8b68-43ee7cb47fea", "name": "4426ee03-4e04-42bf-93e1-5f2e1c49824f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.793928923123666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.7667648924934154, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "55dfe357-873c-47e5-ab06-37d5c04becd5", "name": "921d10ba-5e6b-49f7-b86e-1cd9aa75fb05", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "883d160b-99e7-4ffd-8b68-43ee7cb47fea"}}}]}, {"uuid": "1e183d4f-b8fd-497d-a0ad-f733ce506ce7", "name": "load_p1rlv16445_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e090544-3c8e-4716-9dae-0b311a1017ea"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "55dfe357-873c-47e5-ab06-37d5c04becd5"}}}}, {"uuid": "5a211146-e012-456c-acc9-8cc008eca9a0", "name": "3e340988-092c-4bf0-884c-e6848c72bdba_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5124251878637117, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2529156883724651, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "23ee6240-dfad-4b00-9260-13fe18d5afeb", "name": "c47a35b0-fcfc-44d7-ad74-1fce01a4fee3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5a211146-e012-456c-acc9-8cc008eca9a0"}}}]}, {"uuid": "f8f20623-08e0-49eb-8fd4-80a55e1449e2", "name": "load_p1rlv16570_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53d578d8-8492-471b-8f66-233e489a3652"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "23ee6240-dfad-4b00-9260-13fe18d5afeb"}}}}, {"uuid": "e6193a80-06aa-4c97-bb3a-f13e1fa7f569", "name": "2e814c98-0b7a-40b2-bfd4-cfbb60c0e567_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5124251878637117, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2529156883724651, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d87b565f-a5cf-4cb5-ac56-00d16fe1fba6", "name": "806e10c4-878d-48c1-b69f-077aed7b90ab", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e6193a80-06aa-4c97-bb3a-f13e1fa7f569"}}}]}, {"uuid": "8c31522e-cd10-4472-9fa2-5b897e757d1c", "name": "load_p1rlv16570_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53d578d8-8492-471b-8f66-233e489a3652"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d87b565f-a5cf-4cb5-ac56-00d16fe1fba6"}}}}, {"uuid": "4306f62f-dad2-4a33-bc8d-b31aaa97026e", "name": "1ab8d14c-2283-4cd0-ba17-80293c683a51_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9337862827800336, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34425772205755256, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cb6a0dc7-444c-4267-956a-8b9390366a6c", "name": "ad737204-4fee-40ca-a2c2-99bd4fb6f4d0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4306f62f-dad2-4a33-bc8d-b31aaa97026e"}}}]}, {"uuid": "13635ed1-a73b-4dc9-994c-9462be78e2f2", "name": "load_p1rlv16882_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4faf40b9-9ade-45b5-ade8-3f1833605cd1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cb6a0dc7-444c-4267-956a-8b9390366a6c"}}}}, {"uuid": "5bcd5511-2529-4eb7-8457-f438d0ac891c", "name": "11edd1eb-b4c5-453c-88e0-6f85e656d400_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9337862827800336, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34425772205755256, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bedbef98-fe52-4764-884c-77bb39d1915b", "name": "2d845e5b-b7bc-441a-80ac-faf2ef20b6fa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5bcd5511-2529-4eb7-8457-f438d0ac891c"}}}]}, {"uuid": "fe9e25b6-5829-4ee2-95d3-fc3be395fe81", "name": "load_p1rlv16882_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4faf40b9-9ade-45b5-ade8-3f1833605cd1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bedbef98-fe52-4764-884c-77bb39d1915b"}}}}, {"uuid": "67097ee4-b9be-4d31-9082-f7cf66ee0049", "name": "7e3c2e38-0f54-4726-8760-d92e4426f3d5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7142625617629952, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4166771141877461, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "14d97bf2-c194-4d47-a769-752dcc747f0f", "name": "5a6eaf75-f71b-43c8-ac57-516d27edcc59", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "67097ee4-b9be-4d31-9082-f7cf66ee0049"}}}]}, {"uuid": "8b5cf97f-791d-48cb-ad48-c2d8996a3bb1", "name": "load_p1rlv16904_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c570ef7-c483-4c1e-b0fd-8712e8e9a7cd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "14d97bf2-c194-4d47-a769-752dcc747f0f"}}}}, {"uuid": "e4e83eb7-f622-4640-af52-46e1d50e9da0", "name": "9a014efa-0f29-42bb-aca3-cb1ecfc50a01_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7142625617629952, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4166771141877461, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8af8e30a-1df0-4b5e-a815-a5afb6dbceb1", "name": "4e8548d9-9864-4a11-ae5f-66f3b465cc8b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e4e83eb7-f622-4640-af52-46e1d50e9da0"}}}]}, {"uuid": "857cf48e-9845-4a5a-bf80-2ceb844a67c1", "name": "load_p1rlv16904_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c570ef7-c483-4c1e-b0fd-8712e8e9a7cd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8af8e30a-1df0-4b5e-a815-a5afb6dbceb1"}}}}, {"uuid": "df222f2e-23dd-468f-abac-32289594b03b", "name": "f655d0ce-0bc4-45c4-bb49-ab4042a2ba9e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9815403167210675, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24442739866112323, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bc3ab1a5-9b77-46b0-9f7c-253a91bd57d3", "name": "bae5a9cd-a7ea-4ee4-9283-9944acb0cd4d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "df222f2e-23dd-468f-abac-32289594b03b"}}}]}, {"uuid": "d4a1993f-3687-4bac-b090-3ff6435c1d4e", "name": "load_p1rlv16905_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7578563f-d4b3-423b-a8f5-3ee91a042d19"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bc3ab1a5-9b77-46b0-9f7c-253a91bd57d3"}}}}, {"uuid": "fa94f8b3-d59f-46a5-a6bb-e9b83759f5cc", "name": "b3c28b6d-786a-4772-9800-eea955d5fc28_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9815403167210675, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24442739866112323, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "694a5d1c-d56c-47f4-b69f-6da3db4ec8cb", "name": "8f57c6a1-5078-4d04-9e2a-232279038f1a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fa94f8b3-d59f-46a5-a6bb-e9b83759f5cc"}}}]}, {"uuid": "a91940b7-1c3f-47c8-93b0-e337ac5fb2d4", "name": "load_p1rlv16905_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7578563f-d4b3-423b-a8f5-3ee91a042d19"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "694a5d1c-d56c-47f4-b69f-6da3db4ec8cb"}}}}, {"uuid": "866ee746-a9bb-4d9c-ac8d-b42925c2c936", "name": "16d64a28-9219-4b9e-8f02-0912ba526235_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1343287185333217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10429894918818222, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d281b117-2cfb-4d45-8fed-08e1d7ffcf94", "name": "a81c35a6-347a-4126-a0e4-f8d300079da2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "866ee746-a9bb-4d9c-ac8d-b42925c2c936"}}}]}, {"uuid": "ad5a7f1b-50a3-44c6-9f2c-ea3d4ba82a5c", "name": "load_p1rlv16912_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2308dc3-d10b-4049-862d-caf3356fa9a7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d281b117-2cfb-4d45-8fed-08e1d7ffcf94"}}}}, {"uuid": "44ebafdb-92a3-4071-b231-b704f0339e29", "name": "3a39d6e5-1381-45d2-a9fc-0ad7b0f1f80f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1343287185333217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10429894918818222, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "185703fc-cf0d-4f5b-b80f-56147a287127", "name": "952ebf46-a3d9-4ca9-b4e1-f01b4ce8a248", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "44ebafdb-92a3-4071-b231-b704f0339e29"}}}]}, {"uuid": "fd6e366d-3ed9-4ed3-ad86-5d5dab393117", "name": "load_p1rlv16912_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2308dc3-d10b-4049-862d-caf3356fa9a7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "185703fc-cf0d-4f5b-b80f-56147a287127"}}}}, {"uuid": "73edb9fc-934c-47f0-9015-56196051abfa", "name": "b74a2985-70da-447e-8ac4-c0bd47dea132_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2143639459232007, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7122713279236396, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4710cb21-5f36-4516-ac1e-c0d9f0c0ef39", "name": "53f178ef-52ba-47fa-b976-d30d5d10ccbe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "73edb9fc-934c-47f0-9015-56196051abfa"}}}]}, {"uuid": "43230887-62aa-439a-85e3-abc02603d949", "name": "load_p1rlv16919_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07e01053-37f3-4b9f-a9f1-d51bccd29803"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4710cb21-5f36-4516-ac1e-c0d9f0c0ef39"}}}}, {"uuid": "86d6c8a3-2319-4a32-a922-c9ac44d610dd", "name": "318b9101-6f0f-4353-b5c1-8a27537eef2b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2143639459232007, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7122713279236396, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "919cfc31-0be3-4208-bf84-58b3309fc292", "name": "1b4463c8-f9b7-4cfb-90a3-709b2892605d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "86d6c8a3-2319-4a32-a922-c9ac44d610dd"}}}]}, {"uuid": "a3d23238-a2d4-4e9e-8634-ebbb3d8e4a49", "name": "load_p1rlv16919_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07e01053-37f3-4b9f-a9f1-d51bccd29803"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "919cfc31-0be3-4208-bf84-58b3309fc292"}}}}, {"uuid": "90d19537-202e-4e99-9cdf-927be743f348", "name": "7f3a53b7-4837-4378-a8e1-fc886f275bc3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.639612501586281, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0977377571892493, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ae8b7549-b9c4-42b7-b6aa-eecd7bb1aa64", "name": "c645099e-0bfa-4f86-a6b3-d9b7c7a32c74", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "90d19537-202e-4e99-9cdf-927be743f348"}}}]}, {"uuid": "357d6e7d-d014-4950-8144-fd7502b9f6de", "name": "load_p1rlv16922_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce315d98-1556-429b-aebb-0c868892396a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ae8b7549-b9c4-42b7-b6aa-eecd7bb1aa64"}}}}, {"uuid": "f035a725-f539-40d0-b933-6da8edcb77d5", "name": "d0cf8fdd-fa68-49a4-8977-cf240c7ad71d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.639612501586281, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0977377571892493, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e643043d-ffbf-476a-ac58-ece88d41d61b", "name": "b31151a5-91b8-4e1d-93b7-31bbd6026038", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f035a725-f539-40d0-b933-6da8edcb77d5"}}}]}, {"uuid": "b40d9973-ff90-40bc-81dc-47776eb3ec4d", "name": "load_p1rlv16922_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce315d98-1556-429b-aebb-0c868892396a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e643043d-ffbf-476a-ac58-ece88d41d61b"}}}}, {"uuid": "269e746a-750e-4682-a328-d6112a6b4c81", "name": "a1e2c112-06a4-43cd-8c40-d406276e9962_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8791002615066037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24190904367644575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d77d41b1-5754-48bd-a7e9-50f52f40292b", "name": "94f922d3-6550-4f04-a21f-e2607de92a1a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "269e746a-750e-4682-a328-d6112a6b4c81"}}}]}, {"uuid": "3bf281d4-9ac9-4acf-9a5b-40552c83d5aa", "name": "load_p1rlv16926_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ba1d053-4462-4eb4-aca6-5ede38aa283c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d77d41b1-5754-48bd-a7e9-50f52f40292b"}}}}, {"uuid": "c1f34f7a-2f15-42c3-b742-defc4351a6d7", "name": "e8c1986b-032b-42ac-970b-c9e7d2f39d4f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8791002615066037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24190904367644575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8e73e7fb-0082-427b-bd92-3eab59da11f8", "name": "3b75e35b-133f-42a5-959b-c9303ca23409", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c1f34f7a-2f15-42c3-b742-defc4351a6d7"}}}]}, {"uuid": "c6019ae8-df4a-41f0-97a2-855d85873f24", "name": "load_p1rlv16926_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ba1d053-4462-4eb4-aca6-5ede38aa283c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8e73e7fb-0082-427b-bd92-3eab59da11f8"}}}}, {"uuid": "e4798d07-13c7-4501-b729-ce5eda382096", "name": "78e0bede-b943-41f4-bae9-36cc1b941ed1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.618088489787842, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20923793518521916, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c1a46fd4-dc1f-4a50-921e-34cb0e661c0a", "name": "a477015b-a6b4-4d59-8118-6409d2d5163a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e4798d07-13c7-4501-b729-ce5eda382096"}}}]}, {"uuid": "d25e070f-7ee8-4373-901d-635190d93b31", "name": "load_p1rlv16957_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7dff1455-5154-429f-a33f-044d8501281d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c1a46fd4-dc1f-4a50-921e-34cb0e661c0a"}}}}, {"uuid": "f4578af1-d2ff-4d34-aeb0-e1f28782f43a", "name": "a8087e06-51a4-4993-be20-3a0a57beb633_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.618088489787842, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20923793518521916, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9318be11-995a-4a84-8c1b-fdec953d1314", "name": "bc987390-8d02-46bb-96c3-abc5e3303f43", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f4578af1-d2ff-4d34-aeb0-e1f28782f43a"}}}]}, {"uuid": "b2bfe792-092e-441f-9a3f-1dc753a5797c", "name": "load_p1rlv16957_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7dff1455-5154-429f-a33f-044d8501281d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9318be11-995a-4a84-8c1b-fdec953d1314"}}}}, {"uuid": "820bf4c1-a84c-44fc-bc19-11ed37eede7a", "name": "b21a5757-7bac-4856-9a9c-fc91a7957da8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.625738069985529, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4783299291729874, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ae2df8a9-90b4-4937-8ba7-7d29299cf81a", "name": "1bbaf78b-e251-4fb1-b435-eeb6c539182c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "820bf4c1-a84c-44fc-bc19-11ed37eede7a"}}}]}, {"uuid": "c8dc1e85-f14e-49ac-8c5b-575e8bd62139", "name": "load_p1rlv16988_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11a633b0-2b09-4c66-94d4-d1c24cdd9cf5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ae2df8a9-90b4-4937-8ba7-7d29299cf81a"}}}}, {"uuid": "4fa90c01-ad5c-46ea-9b67-f1f85fb22042", "name": "63dc0f2c-4e69-4774-ae09-76780325d50b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.625738069985529, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4783299291729874, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ce4e0397-bcde-4b5f-8f7d-ce18e8885f2f", "name": "97149d3e-e2d8-419c-be96-c1abb64771c0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4fa90c01-ad5c-46ea-9b67-f1f85fb22042"}}}]}, {"uuid": "7a3dccae-2afa-4b23-b00a-910ae9ee1e94", "name": "load_p1rlv16988_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11a633b0-2b09-4c66-94d4-d1c24cdd9cf5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ce4e0397-bcde-4b5f-8f7d-ce18e8885f2f"}}}}, {"uuid": "4e5f4c5a-680a-4f82-9034-36b07c8af7df", "name": "b885c838-d5dd-401e-ab5b-f72e6a9b3074_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.857442654178314, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2722739314206026, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "70e96277-938a-41c9-872a-8953540c78f5", "name": "ea7d936e-d128-4341-a104-320475c1e68b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4e5f4c5a-680a-4f82-9034-36b07c8af7df"}}}]}, {"uuid": "0779aa7d-23e6-469b-bb88-25f2c5129f2f", "name": "load_p1rlv16992_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57e8aa34-3967-4f22-a978-cb513c49c153"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "70e96277-938a-41c9-872a-8953540c78f5"}}}}, {"uuid": "06636b1d-a342-42c8-8bd7-c49a0ab471d8", "name": "166da0d3-69b9-4e6c-90d7-1000d285d483_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.857442654178314, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2722739314206026, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "518e716f-a60e-4234-b173-d798f3671506", "name": "ab9fd947-c1b8-4877-a6eb-1c2f4401f41f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "06636b1d-a342-42c8-8bd7-c49a0ab471d8"}}}]}, {"uuid": "5bc1200b-19a4-4abd-ba8a-00031764829e", "name": "load_p1rlv16992_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57e8aa34-3967-4f22-a978-cb513c49c153"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "518e716f-a60e-4234-b173-d798f3671506"}}}}, {"uuid": "611fc267-7aa7-4bd8-8a31-aa63454e8e6c", "name": "fc502c9f-1d0c-4059-8f4c-88cd04fc680a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.5934418714018275, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3543697694181257, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "226fb417-254c-4e53-a5be-e88fa31856ff", "name": "0f9c2336-ba2c-4fe5-a661-2f9548ed1a65", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "611fc267-7aa7-4bd8-8a31-aa63454e8e6c"}}}]}, {"uuid": "7d3dd409-551e-4f07-a551-c0f615947d75", "name": "load_p1rlv17001_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f23214ee-3032-4403-9084-8117e89cb1cf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "226fb417-254c-4e53-a5be-e88fa31856ff"}}}}, {"uuid": "5c9d54af-9d15-445e-a04b-4b145ad9f1d8", "name": "5b9f9520-e11b-4645-b326-179d276830e7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.5934418714018275, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3543697694181257, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "30f29dcc-36bf-448b-8a1a-d8548da4f9ad", "name": "28b1e0c3-9834-405c-a87f-2705fc391994", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5c9d54af-9d15-445e-a04b-4b145ad9f1d8"}}}]}, {"uuid": "0310305e-5c68-4087-9f9c-31846d771f30", "name": "load_p1rlv17001_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f23214ee-3032-4403-9084-8117e89cb1cf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "30f29dcc-36bf-448b-8a1a-d8548da4f9ad"}}}}, {"uuid": "df4178c3-55ce-4da9-9e72-0d46e025bcfb", "name": "f7ccd451-931b-4ad7-86d7-540ffdf4d7f1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4585094523583652, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.19519922093662737, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "05dbd0b9-81d8-43a3-8b26-a8d014421a8e", "name": "e289882a-20f6-4105-93ed-2b41595bc8e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "df4178c3-55ce-4da9-9e72-0d46e025bcfb"}}}]}, {"uuid": "c7872ad2-77a0-4783-a58a-0014484bc2fd", "name": "load_p1rlv17028_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "213e6d98-ad57-4034-b2d0-4b096554cac2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "05dbd0b9-81d8-43a3-8b26-a8d014421a8e"}}}}, {"uuid": "9691ae32-fcce-4a5d-b7f9-2e0fd069df12", "name": "990c2f2a-51fa-4f7e-9be8-63cd80dfc8eb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4585094523583652, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.19519922093662737, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f5dbb8ee-a3ac-45d5-8565-cb868d8dcacc", "name": "2e596eab-4423-44c3-bfcd-fe7eab956605", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9691ae32-fcce-4a5d-b7f9-2e0fd069df12"}}}]}, {"uuid": "5118ee7c-01df-439c-8062-4621c59ad19d", "name": "load_p1rlv17028_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "213e6d98-ad57-4034-b2d0-4b096554cac2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f5dbb8ee-a3ac-45d5-8565-cb868d8dcacc"}}}}, {"uuid": "1075be6b-e219-473d-9788-5f8402ae986e", "name": "bc79087e-5b48-4f36-9565-0f6d889bf24a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3439175585507637, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8866404836608991, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b96068ac-8105-447b-87cc-d2dcd76627e9", "name": "c457924a-fe6c-41c2-8832-7e0dc9f8d167", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1075be6b-e219-473d-9788-5f8402ae986e"}}}]}, {"uuid": "de3a713a-805a-4f59-becb-1cf5a6bbf5bc", "name": "load_p1rlv17033_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfa28657-cd8e-4700-a189-83e021f77bee"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b96068ac-8105-447b-87cc-d2dcd76627e9"}}}}, {"uuid": "2b1955b1-62bc-4564-8fe6-35dd39d88f5b", "name": "aa89ade7-79fb-43ce-8080-59b9f57aaa03_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3439175585507637, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8866404836608991, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7b42fd45-8da2-44d9-8b3e-fcb8e439a5d7", "name": "c8b90da3-b732-4357-bb28-78406c91eb32", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2b1955b1-62bc-4564-8fe6-35dd39d88f5b"}}}]}, {"uuid": "abb1148b-4003-47e2-ac8c-b32e08454fca", "name": "load_p1rlv17033_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfa28657-cd8e-4700-a189-83e021f77bee"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7b42fd45-8da2-44d9-8b3e-fcb8e439a5d7"}}}}, {"uuid": "17e5dbaa-c769-4f03-b356-192bf295035c", "name": "191cfe11-c72d-45aa-a247-60bed4ebb772_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7956093485713416, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7629429667228578, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d53f386f-2df8-408d-9e51-aff2cce29ac9", "name": "e265aef2-bb12-431c-92b3-2353267e0ac9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "17e5dbaa-c769-4f03-b356-192bf295035c"}}}]}, {"uuid": "1002f375-c3f6-45cf-b9b1-cc1a38a48e60", "name": "load_p1rlv17059_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "92aff718-b70f-4ea4-b38b-fae69a470c58"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d53f386f-2df8-408d-9e51-aff2cce29ac9"}}}}, {"uuid": "f94714fc-b314-4c3b-a711-f8834d368c24", "name": "dc84c758-bc43-4d6e-8462-d0abdf0f5e91_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7956093485713416, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7629429667228578, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "845cf96b-513d-4834-8ba3-17f15390fbea", "name": "c47f2ca8-56e9-4890-bbe9-6a4ddf9cf345", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f94714fc-b314-4c3b-a711-f8834d368c24"}}}]}, {"uuid": "ffdaa977-c02b-4879-b639-18cc117150d5", "name": "load_p1rlv17059_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "92aff718-b70f-4ea4-b38b-fae69a470c58"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "845cf96b-513d-4834-8ba3-17f15390fbea"}}}}, {"uuid": "770ec631-db34-4b22-a286-0fe45386701a", "name": "352c6d36-cef7-4877-a5a5-ec706ac1b8aa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.969457727539003, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.134389471891055, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "70d017a7-e7af-4d32-a9ae-897881641612", "name": "02b55e58-5a28-4d94-be7a-8c095ffa4eb6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "770ec631-db34-4b22-a286-0fe45386701a"}}}]}, {"uuid": "d95d2f6f-c70e-4459-a852-b572c68f28be", "name": "load_p1rlv17063_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19130741-0fe1-4a12-8a55-96355609bccb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "70d017a7-e7af-4d32-a9ae-897881641612"}}}}, {"uuid": "e6f2358b-ab56-4521-bcd1-15842e7b60ed", "name": "e79d1d03-c7e9-4c3b-b406-1223c85893ee_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.969457727539003, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.134389471891055, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a79830b3-943c-443d-a83d-447940d123f8", "name": "a4593dd7-d942-489a-8b71-eb99f9f1c908", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e6f2358b-ab56-4521-bcd1-15842e7b60ed"}}}]}, {"uuid": "bd0c6050-31cd-4e76-be8f-e483919759fd", "name": "load_p1rlv17063_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19130741-0fe1-4a12-8a55-96355609bccb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a79830b3-943c-443d-a83d-447940d123f8"}}}}, {"uuid": "33fe1973-a21a-4bc8-a818-d2c6639e7533", "name": "714f5256-64f5-4ab0-9b88-7cc020a3ccc9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.922263051512463, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2402658775286277, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a2d73a08-0e8b-4a47-a01e-a4f6632a470b", "name": "c2a74168-1a0f-4204-b165-0b081563d7b0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "33fe1973-a21a-4bc8-a818-d2c6639e7533"}}}]}, {"uuid": "f7903183-a52b-4683-8bad-4d0773ce9007", "name": "load_p1rlv17069_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd48a076-5f8f-426a-b294-183700d1a123"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a2d73a08-0e8b-4a47-a01e-a4f6632a470b"}}}}, {"uuid": "4c5af2eb-8b35-4734-9ad2-817b3ccb6d3b", "name": "70c41a48-a083-4243-ab1d-5fd668ee1edb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.922263051512463, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2402658775286277, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5a08b7b6-26cd-4f5b-a3ef-7ad7476b292e", "name": "f6d0aaa9-95e7-47e3-bf15-8b5ba3ce733e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4c5af2eb-8b35-4734-9ad2-817b3ccb6d3b"}}}]}, {"uuid": "f578c8c4-fa8b-4d9e-9f07-4c804ebfbc3f", "name": "load_p1rlv17069_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd48a076-5f8f-426a-b294-183700d1a123"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5a08b7b6-26cd-4f5b-a3ef-7ad7476b292e"}}}}, {"uuid": "51f7d4f2-a266-4996-b80f-15338891adf1", "name": "1d06895b-42d8-4db3-8829-f756b36c3c76_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5365841293045384, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.535303100231416, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a0d7f2db-b0fe-45ca-8542-f5eedcbeab49", "name": "9de10aa4-24d6-4bf3-9b8a-57d7aa0b9870", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "51f7d4f2-a266-4996-b80f-15338891adf1"}}}]}, {"uuid": "c9d48c81-6c8c-490f-95dd-1ce2d8a0ae45", "name": "load_p1rlv17106_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5439f343-8176-4d92-99d4-bb9209817f6b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a0d7f2db-b0fe-45ca-8542-f5eedcbeab49"}}}}, {"uuid": "20a98f1d-cf86-4461-a79d-c2dc156064c9", "name": "21ab1c11-8243-4bec-8fd0-3e7c7fd1de67_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5365841293045384, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.535303100231416, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6d94ddb0-3dbb-4efe-acff-dfb997f912cd", "name": "12fe9e74-038d-4364-9813-9f3e5ad55a03", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "20a98f1d-cf86-4461-a79d-c2dc156064c9"}}}]}, {"uuid": "50ad8a88-7520-4cdc-ba7d-ff0d57068c1c", "name": "load_p1rlv17106_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5439f343-8176-4d92-99d4-bb9209817f6b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6d94ddb0-3dbb-4efe-acff-dfb997f912cd"}}}}, {"uuid": "8b36242e-6bd4-47a0-9b19-7bb52e4578f9", "name": "9cb374a1-06ea-4585-bed0-445caf08d05e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2874196130666418, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9219654181970236, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f6e11f36-1899-48eb-96e7-39b8e13aa53b", "name": "f1c45f95-14b0-4fe5-9278-4a588750554a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8b36242e-6bd4-47a0-9b19-7bb52e4578f9"}}}]}, {"uuid": "565a8900-809c-4de8-b22c-475b29b2a605", "name": "load_p1rlv17319_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9778ed5-f0c0-44de-b0d4-60659a54fa3b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f6e11f36-1899-48eb-96e7-39b8e13aa53b"}}}}, {"uuid": "ec253a61-eec6-4c57-9c65-7249402675e7", "name": "e5099b75-2916-449c-8052-583f32c20b53_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2874196130666418, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9219654181970236, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e1f66be1-8a64-4033-a446-a9cc4fd4d9c6", "name": "70dce794-59c9-46b4-a978-c63bcdd5170d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ec253a61-eec6-4c57-9c65-7249402675e7"}}}]}, {"uuid": "cf9a64fa-bfdf-49fd-9f95-5e01a1c9fb3b", "name": "load_p1rlv17319_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9778ed5-f0c0-44de-b0d4-60659a54fa3b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e1f66be1-8a64-4033-a446-a9cc4fd4d9c6"}}}}, {"uuid": "09753040-0e6b-4a7d-a2b7-32b34a52ae43", "name": "2c09bf7e-ea77-4ef0-8287-7831413ec4c3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.685213211371405, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7584354740780123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a6a57f47-e0a0-4271-bb83-ecadd10e445b", "name": "114d8058-bcfa-4ee0-b269-3af3608c887d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "09753040-0e6b-4a7d-a2b7-32b34a52ae43"}}}]}, {"uuid": "b8cc302b-3bc8-4b2e-8269-f92fa01fa7c1", "name": "load_p1rlv17320_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79991b02-c0f1-4b9b-a55e-e9b4ff7c17d9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a6a57f47-e0a0-4271-bb83-ecadd10e445b"}}}}, {"uuid": "1339bbd1-699a-457b-86a0-9548e35bffc5", "name": "448ee8a0-22e7-4fe1-803c-4b11107f1619_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.685213211371405, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7584354740780123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "657035af-f4c6-4e4a-9f57-3089797e7891", "name": "2b655e73-8a0e-402c-984b-80f6099048e2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1339bbd1-699a-457b-86a0-9548e35bffc5"}}}]}, {"uuid": "c7144a5c-c9bb-4a10-bd62-2874b0420620", "name": "load_p1rlv17320_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79991b02-c0f1-4b9b-a55e-e9b4ff7c17d9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "657035af-f4c6-4e4a-9f57-3089797e7891"}}}}, {"uuid": "d4da6f6f-0243-45bf-93a6-017baa6f7913", "name": "f760ccd8-5c94-4f50-b4f4-915c44375080_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.651721747239447, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.750976002130125, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0837056c-39b6-4fdb-8d38-7dbdb9184762", "name": "df662db3-42c8-4c75-8d37-5391bef3944e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d4da6f6f-0243-45bf-93a6-017baa6f7913"}}}]}, {"uuid": "239d1bff-f9a1-4edc-bc72-e064e2f577c4", "name": "load_p1rlv17321_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce41ac7c-06c5-435a-957d-c9dda83c1893"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0837056c-39b6-4fdb-8d38-7dbdb9184762"}}}}, {"uuid": "37295526-b584-45ad-92f9-39939c9a4ebf", "name": "a74f6ab6-e8f9-4028-8cf2-8b6085846259_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.651721747239447, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.750976002130125, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c7f44cb0-11c8-4f88-9771-59efe5287350", "name": "e5470d52-e1cb-4b55-973e-749cfe5b1e86", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "37295526-b584-45ad-92f9-39939c9a4ebf"}}}]}, {"uuid": "1b3480aa-cbb6-4442-a899-573ac7b41435", "name": "load_p1rlv17321_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce41ac7c-06c5-435a-957d-c9dda83c1893"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c7f44cb0-11c8-4f88-9771-59efe5287350"}}}}, {"uuid": "235d75c4-2295-44ab-8df0-5cd891f92385", "name": "7e97fd9b-b041-41f6-ae16-1532d47e3390_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.737986692242784, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8906640815201406, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "903aae3b-fcbc-44bf-8758-2d1c89fe8b18", "name": "61bd174e-2446-48ac-a280-97adb323c08d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "235d75c4-2295-44ab-8df0-5cd891f92385"}}}]}, {"uuid": "1535ffaa-5001-4f52-8f80-2852bafe92ad", "name": "load_p1rlv17325_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b96606c-9336-4299-be8d-295c84943a9d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "903aae3b-fcbc-44bf-8758-2d1c89fe8b18"}}}}, {"uuid": "d0a83ebe-9d26-4422-a27d-d362ea0d2275", "name": "15f958a3-c7c3-47b4-9e02-9681fef221f7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.737986692242784, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8906640815201406, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6881f547-3f6e-4678-83c3-557c9ad34cfd", "name": "36aa2e1a-aabb-49f5-b74b-8dd8cb98a9ae", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d0a83ebe-9d26-4422-a27d-d362ea0d2275"}}}]}, {"uuid": "4970ad7b-7fdc-4b8e-a6d9-fb76fc0b981c", "name": "load_p1rlv17325_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b96606c-9336-4299-be8d-295c84943a9d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6881f547-3f6e-4678-83c3-557c9ad34cfd"}}}}, {"uuid": "f8cd7541-9f9c-4029-9050-ac9ae9981b61", "name": "3dd2dcda-5b20-4521-9e1c-533b0f4e2d7d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6912886909314806, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4972799611827758, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ef49f829-a2f1-487a-92ae-0a19154aead2", "name": "a1cb7b13-e07d-4b3a-b665-a622a752c384", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8cd7541-9f9c-4029-9050-ac9ae9981b61"}}}]}, {"uuid": "e86268fa-8ad4-49fe-8411-13873c95c5c1", "name": "load_p1rlv17326_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ceb2d77-2da7-44df-9f28-69ed35835775"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ef49f829-a2f1-487a-92ae-0a19154aead2"}}}}, {"uuid": "cf2f9671-7166-4bed-b0e5-cdfe1a3e3407", "name": "b001c8e1-fbe3-4315-9012-5d7b53544280_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6912886909314806, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4972799611827758, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d12cd93b-3287-4394-ad01-9fe19d458e21", "name": "4194c18c-2067-4de4-a9b2-b7305de03e5d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cf2f9671-7166-4bed-b0e5-cdfe1a3e3407"}}}]}, {"uuid": "04c053de-c88f-429f-8ab5-3ded39fef042", "name": "load_p1rlv17326_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ceb2d77-2da7-44df-9f28-69ed35835775"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d12cd93b-3287-4394-ad01-9fe19d458e21"}}}}, {"uuid": "dcad649d-8185-48c6-b750-d5f463a7a21f", "name": "f871a1d5-2c75-44b5-9c2b-723355efeb26_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8996652652050283, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6342298940221502, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f010069f-ea35-4345-9daa-b8507cb0699f", "name": "ebbd0d99-b2f3-4e55-be22-f03e43cb34d0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dcad649d-8185-48c6-b750-d5f463a7a21f"}}}]}, {"uuid": "af64a22c-b338-4f1d-99e4-adc3f6ce48cd", "name": "load_p1rlv17328_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a43eb022-d5e0-47c8-aa36-6ca0d212ab07"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f010069f-ea35-4345-9daa-b8507cb0699f"}}}}, {"uuid": "33b5235b-19af-4e31-8616-eeb491886df0", "name": "59a7faed-ede4-4c0c-8cd0-53d4d59b4b4b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8996652652050283, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6342298940221502, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "362f1e4e-e82c-4263-ad7a-1736626d9256", "name": "a3751d2c-9cb4-4c6e-8aa2-9609fffb808c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "33b5235b-19af-4e31-8616-eeb491886df0"}}}]}, {"uuid": "a5b20244-ff63-44b8-8128-e65520ab9992", "name": "load_p1rlv17328_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a43eb022-d5e0-47c8-aa36-6ca0d212ab07"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "362f1e4e-e82c-4263-ad7a-1736626d9256"}}}}, {"uuid": "502af279-7eef-4cd6-bc11-335a2d01c6a6", "name": "23f5e75d-4b35-4623-8af6-52bc6d890237_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.965154260277072, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307595255595673, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "03e0b75d-f196-4789-b772-0d0bfcdd7467", "name": "05f90df4-2094-4b44-bcff-622bcb412f47", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "502af279-7eef-4cd6-bc11-335a2d01c6a6"}}}]}, {"uuid": "421c3101-a04f-42d9-8430-d2215058afef", "name": "load_p1rlv17329_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61ef37c1-f14f-4b79-a428-d51a6f0d076a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "03e0b75d-f196-4789-b772-0d0bfcdd7467"}}}}, {"uuid": "bf4e7f5c-06b7-48c3-917d-f780ba6569af", "name": "2c20c9c8-ab35-439c-95b8-88a2bec362ee_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.965154260277072, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307595255595673, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4a990b69-4720-4896-a637-88307f139368", "name": "1c6d8545-b014-47e2-b39c-5c9b64403991", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bf4e7f5c-06b7-48c3-917d-f780ba6569af"}}}]}, {"uuid": "2d364ee8-89df-47d3-925d-bc76de773f9f", "name": "load_p1rlv17329_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61ef37c1-f14f-4b79-a428-d51a6f0d076a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4a990b69-4720-4896-a637-88307f139368"}}}}, {"uuid": "73300fee-aac5-4356-8768-a4c425db1b5c", "name": "d1e15fa3-2da0-4791-91b5-615a9f354c5c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.356365911619733, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.9144830945937485, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f87347ec-7156-4651-b922-6d73776421c8", "name": "b99d852e-feb2-4e27-bfa0-3d0a37d1b68f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "73300fee-aac5-4356-8768-a4c425db1b5c"}}}]}, {"uuid": "e33a1b8c-05d1-4e88-aea1-642e6a4b9283", "name": "load_p1rlv17330_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48ad7bb0-8dd7-457a-b77d-6db2071c2fe7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f87347ec-7156-4651-b922-6d73776421c8"}}}}, {"uuid": "e730a872-297b-4984-9f32-ea11e1223742", "name": "bd4c8eca-463f-417e-ad06-5b4f0592da20_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.356365911619733, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.9144830945937485, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "521fd1db-d248-4a5c-837d-8765dbe26545", "name": "de103423-d263-4bc4-8e5f-616aef1079b5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e730a872-297b-4984-9f32-ea11e1223742"}}}]}, {"uuid": "d780e515-74d8-40c6-a7b7-c9071c69af6d", "name": "load_p1rlv17330_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48ad7bb0-8dd7-457a-b77d-6db2071c2fe7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "521fd1db-d248-4a5c-837d-8765dbe26545"}}}}, {"uuid": "1bfcde87-02bf-4ce9-8ed4-7209cb2e19d7", "name": "0295af67-ecd0-486b-af5e-69d9a5cdfe46_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.255903801273714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9789336651099453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "80309df0-588d-49c0-ad64-99b3de9933af", "name": "e0617d38-b588-4c31-9ee1-be55b341fb67", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1bfcde87-02bf-4ce9-8ed4-7209cb2e19d7"}}}]}, {"uuid": "366eed2b-9cc7-4cc8-9a6d-f23d8620b83d", "name": "load_p1rlv17333_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33b66eb9-3b21-4f92-b19b-6a0eef4134d8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "80309df0-588d-49c0-ad64-99b3de9933af"}}}}, {"uuid": "6ae4fcd8-c7f9-45bb-aac8-956b026448cc", "name": "cff104dd-acb7-4b9a-91d7-e355b76ea6b7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.255903801273714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9789336651099453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "abf2ae54-b1d6-4d72-a05f-98f931da19aa", "name": "bd7f4c86-5f03-4e9d-a761-526843704029", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6ae4fcd8-c7f9-45bb-aac8-956b026448cc"}}}]}, {"uuid": "b58c0573-6035-407e-b046-33984fd2092c", "name": "load_p1rlv17333_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33b66eb9-3b21-4f92-b19b-6a0eef4134d8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "abf2ae54-b1d6-4d72-a05f-98f931da19aa"}}}}, {"uuid": "38389ae1-540a-4b72-aa42-af02254ae37f", "name": "657c8f54-5aaa-4854-8bec-9057bdcd69c8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4460841500077097, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.15562665537022718, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dee75f5a-8383-4ed1-9bcb-b2bcf07eb44c", "name": "5f368daa-20fb-4310-ab20-38e603dd0dda", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "38389ae1-540a-4b72-aa42-af02254ae37f"}}}]}, {"uuid": "76335f13-60ce-41e1-9026-922a1d9ecad6", "name": "load_p1rlv17334_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4970bc03-bc57-4a42-b0cb-66002af1709e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dee75f5a-8383-4ed1-9bcb-b2bcf07eb44c"}}}}, {"uuid": "7f4ebfe0-40c5-4bc9-8d1b-595aba889280", "name": "d1f4d03d-b29c-4558-a26c-8a63b1703fbb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4460841500077097, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.15562665537022718, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f40e8fbd-f09a-4cdc-8726-aadbe95b7361", "name": "9e000e2d-2767-4d2f-9a5a-ebc1aace4bc6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7f4ebfe0-40c5-4bc9-8d1b-595aba889280"}}}]}, {"uuid": "4f7252ce-8e0f-41f4-ae5f-1e75102a5f20", "name": "load_p1rlv17334_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4970bc03-bc57-4a42-b0cb-66002af1709e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f40e8fbd-f09a-4cdc-8726-aadbe95b7361"}}}}, {"uuid": "7770234d-62d4-4e13-93b8-9faa62388024", "name": "4c0ed79f-20c9-4da8-9fc7-9b40e54ee282_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.359977223622412, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2969054470018346, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d1ccdca0-093d-4453-a542-dfb77fd0c26f", "name": "735ac888-54bc-4df2-8549-bcd8f865f7ae", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7770234d-62d4-4e13-93b8-9faa62388024"}}}]}, {"uuid": "d7fc5468-3384-4827-b882-e6713879f684", "name": "load_p1rlv17336_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b645969-9136-42a9-b5ac-7d2f1ff71959"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d1ccdca0-093d-4453-a542-dfb77fd0c26f"}}}}, {"uuid": "bc11a223-15f9-48b8-b73b-8370380bc9fd", "name": "19cfeaa7-2b0c-4f67-ac42-d0300df652fb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.359977223622412, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2969054470018346, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e69fe531-0740-4468-9fe7-288bd3769e5f", "name": "5ff19b73-e67a-42e3-9192-f3a4f27649df", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bc11a223-15f9-48b8-b73b-8370380bc9fd"}}}]}, {"uuid": "8396bf77-6765-45f5-82e9-242a84e70f48", "name": "load_p1rlv17336_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b645969-9136-42a9-b5ac-7d2f1ff71959"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e69fe531-0740-4468-9fe7-288bd3769e5f"}}}}, {"uuid": "0f8feaae-af20-4ec3-8b23-e952cb4a6d6e", "name": "83159870-f9d3-442a-97aa-8a42631c32f5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.157838539018536, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.1846823736377714, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "98bd2f16-26b5-47f5-87b1-b3b75c6eb722", "name": "b53c729d-dc99-403d-9bfb-61ee0f06c0ac", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0f8feaae-af20-4ec3-8b23-e952cb4a6d6e"}}}]}, {"uuid": "6e1b9ad7-c909-4865-8432-e7ff483d75c1", "name": "load_p1rlv17337_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5d7049e-9d30-474c-9033-3ad9b4487f7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "98bd2f16-26b5-47f5-87b1-b3b75c6eb722"}}}}, {"uuid": "23ea3d41-4fb0-400f-b006-de183516f61c", "name": "b9274f04-6d81-4bdc-b6b4-9d251c80c79f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.157838539018536, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.1846823736377714, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5e6a5815-3cb1-4b23-9e57-d203e5d85c62", "name": "97315a0a-6423-4943-9a7c-8b41539a03cb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "23ea3d41-4fb0-400f-b006-de183516f61c"}}}]}, {"uuid": "684f5533-f848-4fe6-afd9-8445ebb46174", "name": "load_p1rlv17337_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5d7049e-9d30-474c-9033-3ad9b4487f7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5e6a5815-3cb1-4b23-9e57-d203e5d85c62"}}}}, {"uuid": "5c054edd-c1ec-4d63-b7fd-2207354a66cc", "name": "0b5b75ef-8e44-46a6-a040-396856a4ca71_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.241859724602562, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.250877899038581, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "62397ab6-6a05-426d-8dc3-584c053fff44", "name": "883f491d-1400-4a65-a1fa-92903e5d220f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5c054edd-c1ec-4d63-b7fd-2207354a66cc"}}}]}, {"uuid": "f32efdb4-559e-490e-b395-2486691c556e", "name": "load_p1rlv17338_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "331389ab-5d04-4648-83b4-3043198c774f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "62397ab6-6a05-426d-8dc3-584c053fff44"}}}}, {"uuid": "69d97f87-0ce5-4dad-84fe-c0820689c482", "name": "5c9344f5-ed54-4a4e-9556-05651f149697_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.241859724602562, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.250877899038581, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bdd66b0e-efdd-4dbb-a880-a563704bab7f", "name": "dc6d0468-96f6-4234-8881-da3ca3c8a732", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "69d97f87-0ce5-4dad-84fe-c0820689c482"}}}]}, {"uuid": "24b04968-809c-4f9e-82c9-2393f24ced06", "name": "load_p1rlv17338_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "331389ab-5d04-4648-83b4-3043198c774f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bdd66b0e-efdd-4dbb-a880-a563704bab7f"}}}}, {"uuid": "7d6f6682-4b16-4d78-8341-02dff6a588fe", "name": "5fcda203-655d-453f-95e9-d856be4dda50_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.949137985829372, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.575540256876006, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e10dccc6-c7b1-47cd-88f9-ba4e865bb912", "name": "349bdcdc-edbb-489d-acac-32c5c19e07d2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7d6f6682-4b16-4d78-8341-02dff6a588fe"}}}]}, {"uuid": "72c9ade7-113c-41e7-9225-8cff048b643b", "name": "load_p1rlv17702_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7acb4e7d-cb06-4848-952d-7c68bb34b6db"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e10dccc6-c7b1-47cd-88f9-ba4e865bb912"}}}}, {"uuid": "be52c1ba-3322-4d4f-a639-ed481cdafb06", "name": "1c903b5f-69b3-4a5f-826c-408a365c6bd8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.949137985829372, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.575540256876006, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "450b1b56-3277-4891-bb72-afcc79768b33", "name": "2789a382-ddb9-43ab-bc92-aec08e51abb1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "be52c1ba-3322-4d4f-a639-ed481cdafb06"}}}]}, {"uuid": "5fc87cb6-ada6-4067-b553-daebcf1caece", "name": "load_p1rlv17702_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7acb4e7d-cb06-4848-952d-7c68bb34b6db"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "450b1b56-3277-4891-bb72-afcc79768b33"}}}}, {"uuid": "54432679-b6b2-4d78-ab72-45c674f6e4c7", "name": "cbff83cc-f4cb-4058-a0fc-21d41805ea63_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.965154260277072, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307595255595673, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b029dfda-8738-4211-924a-5b1ccf2b13c9", "name": "e0b5bc66-cdee-4562-9a95-1f343869399a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "54432679-b6b2-4d78-ab72-45c674f6e4c7"}}}]}, {"uuid": "f405c86c-6283-4e82-94df-f7684c805921", "name": "load_p1rlv17781_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a52db2ff-b782-40c1-828a-c65f6929b2fc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b029dfda-8738-4211-924a-5b1ccf2b13c9"}}}}, {"uuid": "1e999895-719f-4b49-b2c7-7a104578adb6", "name": "8bc0e0ee-ff40-4d1e-baee-9f86e3507dbf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.965154260277072, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307595255595673, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2079d6c3-7144-4c92-bc10-aeffc20e685f", "name": "9a9e85ad-5a1d-44fb-b0e2-22b93b6b85b5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1e999895-719f-4b49-b2c7-7a104578adb6"}}}]}, {"uuid": "a61d4b03-911d-42f1-9f8d-c407beccdbeb", "name": "load_p1rlv17781_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a52db2ff-b782-40c1-828a-c65f6929b2fc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2079d6c3-7144-4c92-bc10-aeffc20e685f"}}}}, {"uuid": "3d87410e-83fa-4503-a32b-42bffa2ade70", "name": "9ebe8467-6d47-4b96-aa2a-cc848e2cf97e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.4509454152189125, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9978822313633423, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "198a11c5-9d1e-4caf-a3fd-831192a81b57", "name": "846dcd18-3cee-466e-83b5-1959f08516b3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3d87410e-83fa-4503-a32b-42bffa2ade70"}}}]}, {"uuid": "48206521-093e-4330-82af-1b8be5c79b02", "name": "load_p1rlv17787_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c9c1d9f-eeff-454f-b3d0-7e7de837694c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "198a11c5-9d1e-4caf-a3fd-831192a81b57"}}}}, {"uuid": "163ec51c-f0c1-492c-9666-21946210daaf", "name": "29b335a2-eaf9-48da-817a-17d7c348ac1d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.4509454152189125, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9978822313633423, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8058e3d1-c5b1-4e29-bd83-99287167a6c4", "name": "e1e33dda-f889-4d56-993e-273a46436294", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "163ec51c-f0c1-492c-9666-21946210daaf"}}}]}, {"uuid": "a7bfce45-0f3d-4e66-b3ea-051b6d8c0cf3", "name": "load_p1rlv17787_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c9c1d9f-eeff-454f-b3d0-7e7de837694c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8058e3d1-c5b1-4e29-bd83-99287167a6c4"}}}}, {"uuid": "7b857081-2d81-4bc4-a793-593d6a41b721", "name": "69e968b9-c607-4afc-8481-09a084bce421_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8534881847076217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.812795269620709, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0adc15f9-14b0-4e0c-b445-d886b5f3c16e", "name": "a0a04716-5d5d-4c1e-aa2b-43c7fad31167", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b857081-2d81-4bc4-a793-593d6a41b721"}}}]}, {"uuid": "78c99f01-deb9-4359-9ee0-bb0448e0955b", "name": "load_p1rlv17798_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9dba02d-086c-4906-9c6f-86532e3384c0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0adc15f9-14b0-4e0c-b445-d886b5f3c16e"}}}}, {"uuid": "8555fc92-e9ab-4ffe-b86c-713c278c23fb", "name": "ac94db1f-9834-4f23-8a46-337a25965209_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8534881847076217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.812795269620709, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0cc910e3-3490-41d8-bbf8-a3487362ef2d", "name": "4a6c21e0-2ca4-442d-8d28-1b9ffe7f3dcf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8555fc92-e9ab-4ffe-b86c-713c278c23fb"}}}]}, {"uuid": "aa5c1c56-5a37-4ada-9466-b39ca4a4ea34", "name": "load_p1rlv17798_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9dba02d-086c-4906-9c6f-86532e3384c0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0cc910e3-3490-41d8-bbf8-a3487362ef2d"}}}}, {"uuid": "5f9ef80b-6b91-445d-a78e-777ec0e81b50", "name": "f92c31a2-9402-4e54-9e0f-1de381a81ec1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6844632506969115, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4071315730781585, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d7df6801-627e-4f73-ad3d-f2e3d628eff9", "name": "9efd73ab-497f-47f0-8980-6551b60ee625", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5f9ef80b-6b91-445d-a78e-777ec0e81b50"}}}]}, {"uuid": "3f9bdf0e-f89f-46e9-a0d2-587640eb27bc", "name": "load_p1rlv17810_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3887a879-0783-4703-8a24-32b7e3b4f39d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d7df6801-627e-4f73-ad3d-f2e3d628eff9"}}}}, {"uuid": "14d19e97-d917-49f8-8726-06d23e6a61f8", "name": "58baa9eb-f123-4e37-8b30-8735fcd7f441_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6844632506969115, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4071315730781585, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "445ea327-9707-4c4e-b794-9288514689f9", "name": "52f7ab9d-9e50-48b6-81f3-75cd2228557b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "14d19e97-d917-49f8-8726-06d23e6a61f8"}}}]}, {"uuid": "2f28be03-818a-4f93-af62-e804e4f8052b", "name": "load_p1rlv17810_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3887a879-0783-4703-8a24-32b7e3b4f39d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "445ea327-9707-4c4e-b794-9288514689f9"}}}}, {"uuid": "e14a7e0c-44e6-4636-9145-5902e8696f58", "name": "3454769d-7d63-4a7f-9fe0-6062947119bf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.136651452497737, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.586908988148888, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "25e771ac-e957-447e-8569-3b5b9a12e970", "name": "5674eef4-41c9-43f4-bbe8-54b74a5533d8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e14a7e0c-44e6-4636-9145-5902e8696f58"}}}]}, {"uuid": "c72a25b6-0826-41ad-a0d8-f7b0c4265083", "name": "load_p1rlv17847_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f7776e4-a81f-48d2-b3c0-d70bfa48164e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "25e771ac-e957-447e-8569-3b5b9a12e970"}}}}, {"uuid": "4cf6afae-55af-4626-8b4e-7dbefc832603", "name": "330a397d-5aff-4cbf-aff8-b9fcc9e7f79f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.136651452497737, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.586908988148888, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "35baf397-b50d-4e62-9f61-77b4a7ea8418", "name": "444cc47d-e24e-4637-85d4-6a37566cd207", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4cf6afae-55af-4626-8b4e-7dbefc832603"}}}]}, {"uuid": "eee5393e-00d6-46c7-b18b-a0f91f0d99fe", "name": "load_p1rlv17847_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f7776e4-a81f-48d2-b3c0-d70bfa48164e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "35baf397-b50d-4e62-9f61-77b4a7ea8418"}}}}, {"uuid": "6e098042-e93f-4831-8ac8-ae75c7f70985", "name": "ef62be26-4c67-45c8-99db-2e14e7c2275b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3135149757913545, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7371070877725675, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7a47240f-01a4-41ee-b4b9-72dc87b5daec", "name": "ceca9648-b1df-47a9-9014-80d9e01f1dd8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6e098042-e93f-4831-8ac8-ae75c7f70985"}}}]}, {"uuid": "5498629b-d009-4516-acf5-664b97cf89c2", "name": "load_p1rlv17857_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0827675c-2467-403d-822e-5f74cd6296c5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7a47240f-01a4-41ee-b4b9-72dc87b5daec"}}}}, {"uuid": "a47d8cd3-ed11-4b5f-9db3-c4a0034a9ca4", "name": "fb659191-f009-41b2-b21f-120fa0247c8f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3135149757913545, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7371070877725675, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fca87ce0-49b3-4835-820a-8be2bcae6903", "name": "251ff752-b29c-40ce-bba4-4314bc46db73", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a47d8cd3-ed11-4b5f-9db3-c4a0034a9ca4"}}}]}, {"uuid": "c858a7f0-8223-4efb-a2d9-b2882fb6d971", "name": "load_p1rlv17857_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0827675c-2467-403d-822e-5f74cd6296c5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fca87ce0-49b3-4835-820a-8be2bcae6903"}}}}, {"uuid": "785da82f-5373-452b-8227-90ab120ca7b4", "name": "56bf38fa-cd89-4dbe-8b53-49af2e32ed1f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.443583112785006, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2576306570382033, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fef70936-b654-42b2-be1b-86b55a67b30a", "name": "79526ef0-8a1f-4b6e-843f-8bb1698ea65f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "785da82f-5373-452b-8227-90ab120ca7b4"}}}]}, {"uuid": "a4d5dbc3-0330-411d-8a82-6a7737083b0e", "name": "load_p1rlv17876_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75e55237-b847-4fb7-a141-a0771bd868c6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fef70936-b654-42b2-be1b-86b55a67b30a"}}}}, {"uuid": "1e9a1961-e7a9-4146-80c2-cf66003e17ba", "name": "72125487-3fd7-4146-bfb6-029c8fb66e97_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.443583112785006, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2576306570382033, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b1747e1a-b340-4027-b5b4-cdc0451196ad", "name": "66e84d45-331d-4185-a59d-2323e03033d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1e9a1961-e7a9-4146-80c2-cf66003e17ba"}}}]}, {"uuid": "57dc88b8-3fa0-4d70-9b9e-b9d84be074a7", "name": "load_p1rlv17876_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75e55237-b847-4fb7-a141-a0771bd868c6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b1747e1a-b340-4027-b5b4-cdc0451196ad"}}}}, {"uuid": "2a816c78-b7c5-4dae-86bc-556d575808b4", "name": "f8759381-73dd-4b2d-9110-80d5e846c70e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1426015471760884, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5928311844731246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cc7bc10a-874e-4459-af46-b5b0f7ad1bc6", "name": "93601803-22d6-4ad7-bb7d-e7211b2a59ff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2a816c78-b7c5-4dae-86bc-556d575808b4"}}}]}, {"uuid": "7a66ce02-8f45-4802-ae36-c25ff587b520", "name": "load_p1rlv17877_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f44b0293-61e5-4054-b2d7-4a113df92b3c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cc7bc10a-874e-4459-af46-b5b0f7ad1bc6"}}}}, {"uuid": "0c3e0615-8667-4df0-b786-134737220183", "name": "e87fd7ce-4d9e-463c-8d0a-3c500e9b8401_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1426015471760884, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5928311844731246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2efdaf05-7c0b-491c-9674-03bc78329797", "name": "f88041bf-92ed-424b-820b-e0481e549c88", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0c3e0615-8667-4df0-b786-134737220183"}}}]}, {"uuid": "613a4a65-8be2-4936-a8bd-f65d054605f7", "name": "load_p1rlv17877_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f44b0293-61e5-4054-b2d7-4a113df92b3c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2efdaf05-7c0b-491c-9674-03bc78329797"}}}}, {"uuid": "747c2cc6-2d86-4f59-9ca8-530bb0f6ba8d", "name": "46b5cdf4-3ff2-4a1c-bef2-2d57a001d3ef_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.67620786252276, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6753067705079763, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0af8c976-a6e0-4470-bc59-1d8800943c1a", "name": "1d4b0369-7042-401d-a28a-16884ca6b2c7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "747c2cc6-2d86-4f59-9ca8-530bb0f6ba8d"}}}]}, {"uuid": "e3f310df-f0c4-4b89-9432-0bab91f2241d", "name": "load_p1rlv17897_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f74f217-4765-406d-9646-d8f46377ef0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0af8c976-a6e0-4470-bc59-1d8800943c1a"}}}}, {"uuid": "0c405577-dccd-493a-bd4b-e52011412b9e", "name": "deab8b54-668c-47ff-8a8c-9d158ba82837_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.67620786252276, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6753067705079763, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c33af26c-c73a-4bf3-8252-dd6b48f69ce1", "name": "bd9a4bb0-985a-4626-9645-2d8b3c4c0fec", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0c405577-dccd-493a-bd4b-e52011412b9e"}}}]}, {"uuid": "3ac79b34-2d50-40be-baa0-efbb85f6253d", "name": "load_p1rlv17897_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f74f217-4765-406d-9646-d8f46377ef0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c33af26c-c73a-4bf3-8252-dd6b48f69ce1"}}}}, {"uuid": "673954b0-f374-4cea-81d2-77aae21ac239", "name": "c7ca9f33-6dee-4b99-ab2e-c6fd7b8f141c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3841896439528762, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.62886585412856, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "43870935-1fbe-4419-a912-eabaf277738d", "name": "1f44b787-71df-4d82-892f-ed486384c677", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "673954b0-f374-4cea-81d2-77aae21ac239"}}}]}, {"uuid": "f146f258-d046-4e2f-92cf-fa17ae5d53a8", "name": "load_p1rlv17909_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab733d49-bb36-4631-8824-1967f98f758a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "43870935-1fbe-4419-a912-eabaf277738d"}}}}, {"uuid": "b0f16155-341f-4fef-9b89-4ba76fa3fa9b", "name": "184ed837-46d1-48b6-9e40-41454e4f4529_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3841896439528762, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.62886585412856, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0cc76fc8-659e-45fa-8c82-49735e94aa6e", "name": "756b0c1d-4183-4f16-93fb-62c0a6c14c1b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b0f16155-341f-4fef-9b89-4ba76fa3fa9b"}}}]}, {"uuid": "8b089298-c576-4ac5-8380-4d3a995dd365", "name": "load_p1rlv17909_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab733d49-bb36-4631-8824-1967f98f758a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0cc76fc8-659e-45fa-8c82-49735e94aa6e"}}}}, {"uuid": "85580e6f-4336-4378-8593-aa5e7f997af6", "name": "c78d97da-dbb2-40cc-a767-670b78cef609_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5290895920961123, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.36247808422876804, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "737497c3-2c01-4ab2-a5db-da56979d37c2", "name": "ab66c99b-9660-48d5-a102-d31d5ad73bc4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "85580e6f-4336-4378-8593-aa5e7f997af6"}}}]}, {"uuid": "554a2fbd-8de1-491f-9962-641362d00fec", "name": "load_p1rlv17912_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3eb66d3-0271-4842-8893-9a58f64e0279"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "737497c3-2c01-4ab2-a5db-da56979d37c2"}}}}, {"uuid": "35e16783-6c79-4cb2-8388-75a45ee8381c", "name": "27882881-f8f6-46ab-afa3-e2c94a85c378_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5290895920961123, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.36247808422876804, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "32cacb6c-cb9e-4d0b-bb0b-6ecc9421fcf1", "name": "2b39f0f8-eee4-4971-9ef8-b5929d463593", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "35e16783-6c79-4cb2-8388-75a45ee8381c"}}}]}, {"uuid": "ab4939ac-f9c6-4ce9-9625-94b0d4bcd5dc", "name": "load_p1rlv17912_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3eb66d3-0271-4842-8893-9a58f64e0279"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "32cacb6c-cb9e-4d0b-bb0b-6ecc9421fcf1"}}}}, {"uuid": "f121e983-b923-4500-a667-b0c458477d72", "name": "c4c3ef96-98c9-4de0-87a3-17dba1f39788_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.53872088738556, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0484090155056416, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "58b14df9-08c0-4c7d-8ffc-c69eb560f186", "name": "7454fbd0-0e55-4473-851a-edf12b088e6e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f121e983-b923-4500-a667-b0c458477d72"}}}]}, {"uuid": "72a62921-b6d9-4e38-948d-caef55f4832f", "name": "load_p1rlv17926_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2812bbb1-0bb0-499f-a394-0995784bb7bc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "58b14df9-08c0-4c7d-8ffc-c69eb560f186"}}}}, {"uuid": "c9d24559-cd5e-43ad-b30e-90aa7792fc53", "name": "467c2215-dde7-4a09-a503-571ccf8670c0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.53872088738556, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0484090155056416, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "873ca082-8d2a-4bbd-b64a-200399a7fa2e", "name": "ba080ed0-a082-40d1-870d-4cd6e9d28483", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9d24559-cd5e-43ad-b30e-90aa7792fc53"}}}]}, {"uuid": "dfa5b295-8bae-42f3-bac4-7cbd34dbd9b5", "name": "load_p1rlv17926_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2812bbb1-0bb0-499f-a394-0995784bb7bc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "873ca082-8d2a-4bbd-b64a-200399a7fa2e"}}}}, {"uuid": "a51df733-a1a0-44c8-b6da-4e51ae456dab", "name": "9727774c-93bc-41c4-8516-53ded346a01a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9243645178497548, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1029763549760416, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0b144409-29f3-4aae-973f-de0f15942722", "name": "f9d605d1-f989-4bbe-8d7d-3ee66c387489", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a51df733-a1a0-44c8-b6da-4e51ae456dab"}}}]}, {"uuid": "8dcabd59-b0bb-4578-9b9a-ddf3e05199bc", "name": "load_p1rlv17960_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "215a5974-e23b-46f0-bde9-f5ad16fdfaf8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0b144409-29f3-4aae-973f-de0f15942722"}}}}, {"uuid": "18d35654-eabd-48ad-b40e-e1a5f9d70b65", "name": "49f0a928-a1cd-4c63-b22d-ca6193302c0f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9243645178497548, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1029763549760416, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aed5f5f5-d1fc-428c-a25d-04a11d59a468", "name": "175c910f-8a28-4c5a-91dc-3c92d43f6a92", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "18d35654-eabd-48ad-b40e-e1a5f9d70b65"}}}]}, {"uuid": "7d94f70f-8b62-40ed-8e1a-3ef30f8baa32", "name": "load_p1rlv17960_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "215a5974-e23b-46f0-bde9-f5ad16fdfaf8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aed5f5f5-d1fc-428c-a25d-04a11d59a468"}}}}, {"uuid": "bef3716f-841e-42a0-b5c6-ad05d7d4b39e", "name": "40099928-ff6e-442e-926b-0313269e41dc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.498014754859445, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "38bf2759-9d5a-4191-81c9-7b6a88469a70", "name": "824f1227-95e5-416c-a14b-112fac6a710b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bef3716f-841e-42a0-b5c6-ad05d7d4b39e"}}}]}, {"uuid": "994236b6-d001-4192-9f84-405c6a284793", "name": "load_p1rlv17961_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2716887e-1701-4a78-805b-96da0781c7f8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "38bf2759-9d5a-4191-81c9-7b6a88469a70"}}}}, {"uuid": "e0606768-9b13-4f11-a250-4360c3e94b74", "name": "428da6b8-fa3a-4e61-9877-bb07755f3169_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.498014754859445, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dff768e5-d8c7-42b4-b30a-4e42f71261e9", "name": "9caf0ad2-af21-40a4-9e1a-a10322d5057f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e0606768-9b13-4f11-a250-4360c3e94b74"}}}]}, {"uuid": "eb5a0498-5956-4b87-9295-49e532a7dfe7", "name": "load_p1rlv17961_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2716887e-1701-4a78-805b-96da0781c7f8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dff768e5-d8c7-42b4-b30a-4e42f71261e9"}}}}, {"uuid": "9efb896d-0011-455d-b26f-581c13ab6ba1", "name": "e8f4e742-6ae7-41d1-aea6-4737074853a8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4651344294517608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7736313908316925, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1e24c802-acb4-4c9d-8e8b-82548499c030", "name": "20f50e06-ba44-4c08-a440-ac3d0c0ff194", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9efb896d-0011-455d-b26f-581c13ab6ba1"}}}]}, {"uuid": "522399a3-eb8a-4295-a203-4ad7992130ab", "name": "load_p1rlv17962_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec99daac-e0be-4ea1-ba4f-185d4943396d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1e24c802-acb4-4c9d-8e8b-82548499c030"}}}}, {"uuid": "929ca6ca-a3ce-42e9-a5e6-6a795631e22f", "name": "b3e41a9f-aa35-425f-ac89-4956de4a32e6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4651344294517608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7736313908316925, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a0ae656-44fb-451e-9ce3-335ca2aa43ad", "name": "5fd5411c-5965-4e7f-bef9-5bcb02bfb77e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "929ca6ca-a3ce-42e9-a5e6-6a795631e22f"}}}]}, {"uuid": "1cc045b5-a3a0-4869-a60f-a759e5eb16dd", "name": "load_p1rlv17962_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec99daac-e0be-4ea1-ba4f-185d4943396d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a0ae656-44fb-451e-9ce3-335ca2aa43ad"}}}}, {"uuid": "80c1306a-2395-499e-8d7b-a00ea5cbc1f5", "name": "36e9c8af-fb21-4fd7-ab9a-069eb5405324_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.107858967059457, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3651352875232526, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "575b6888-0bd4-41d2-b5c0-3b2efbd2bc27", "name": "4da172cc-66c4-41ea-a05f-8bc6c686b27a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "80c1306a-2395-499e-8d7b-a00ea5cbc1f5"}}}]}, {"uuid": "1a13d31f-dd8c-48db-9566-bb8555ff2eb6", "name": "load_p1rlv17969_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ccaf70a-35d8-4f16-b632-e282fe30b5ca"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "575b6888-0bd4-41d2-b5c0-3b2efbd2bc27"}}}}, {"uuid": "356eac4e-c227-4733-ad20-430ccd100a54", "name": "3bb91beb-def4-4ac9-837d-d19d44558d5b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.107858967059457, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3651352875232526, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4b44aed9-c5e4-43b8-850e-8d81021d55fa", "name": "c94f6aee-952d-4b57-8918-e23555512cf6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "356eac4e-c227-4733-ad20-430ccd100a54"}}}]}, {"uuid": "9bc6eff4-5e3a-4c95-9a8d-c503e9b2f022", "name": "load_p1rlv17969_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ccaf70a-35d8-4f16-b632-e282fe30b5ca"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4b44aed9-c5e4-43b8-850e-8d81021d55fa"}}}}, {"uuid": "7c8c52d7-c1da-4a84-9f8b-6da12b106261", "name": "e8394590-bd10-43e1-8be7-11875e03895a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8939358223380807, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6690937458929831, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "15f03cc3-4b5f-44ca-bf57-a3bfdbcaf20c", "name": "e884a5e6-d820-4ea9-88d5-f95975577ddd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7c8c52d7-c1da-4a84-9f8b-6da12b106261"}}}]}, {"uuid": "761d9060-9915-4396-823f-9d89270cc816", "name": "load_p1rlv17987_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0771ebfa-5eaf-4ae8-94f1-86de7a656f58"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "15f03cc3-4b5f-44ca-bf57-a3bfdbcaf20c"}}}}, {"uuid": "09143581-c632-4b97-9e2d-846f065ae568", "name": "c79622ae-1a19-4bd6-9a02-44a40c1271ed_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8939358223380807, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6690937458929831, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0770b80e-1ba4-4142-bbad-cb21fc5a7bf0", "name": "8e94e562-b508-49aa-9243-e8ee4ca25e68", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "09143581-c632-4b97-9e2d-846f065ae568"}}}]}, {"uuid": "55c4c05e-ffa0-4950-ab16-60ea16d44777", "name": "load_p1rlv17987_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0771ebfa-5eaf-4ae8-94f1-86de7a656f58"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0770b80e-1ba4-4142-bbad-cb21fc5a7bf0"}}}}, {"uuid": "7d268e87-7787-4271-8a16-4ca5cbd5b1ad", "name": "8f2eb056-9539-463c-bd7d-a24c464d0f5b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0404861968223509, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5307917165881004, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f336219e-e2ac-4bc3-a323-65e4d9edb635", "name": "c8fffeef-26c4-4fb7-a4e3-d188a91238ac", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7d268e87-7787-4271-8a16-4ca5cbd5b1ad"}}}]}, {"uuid": "c7e08a67-99af-4662-9700-745aab48ccab", "name": "load_p1rlv18044_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b40fac8c-a99b-4baa-940a-26565ba7d62b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f336219e-e2ac-4bc3-a323-65e4d9edb635"}}}}, {"uuid": "fd34ef56-f97c-4d4e-91c8-1b0e1d0d6fd7", "name": "7e460095-9f92-44b2-b8b5-9fab9d29e144_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0404861968223509, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5307917165881004, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "420f9a97-b7fc-4c97-b066-8df50a178869", "name": "329acef9-99ed-4b46-8b52-a131f586e947", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fd34ef56-f97c-4d4e-91c8-1b0e1d0d6fd7"}}}]}, {"uuid": "47e7ab04-3e9f-430e-be73-1584529a1096", "name": "load_p1rlv18044_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b40fac8c-a99b-4baa-940a-26565ba7d62b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "420f9a97-b7fc-4c97-b066-8df50a178869"}}}}, {"uuid": "5df3cb72-beb9-4ad3-b570-6d9cc60d23da", "name": "1b28d631-8654-4420-a891-23e721aae671_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.199673234956728, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.25859312667494616, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3adf9d10-fdb0-4c38-bf75-0d97ef0b4aaa", "name": "ec3d2672-b86c-4faf-9e3e-1457857bc427", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5df3cb72-beb9-4ad3-b570-6d9cc60d23da"}}}]}, {"uuid": "f12b8f76-6571-4c39-bfdd-40132252b81e", "name": "load_p1rlv18053_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4aeda1c7-41be-43c8-82e5-d7a347db86a8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3adf9d10-fdb0-4c38-bf75-0d97ef0b4aaa"}}}}, {"uuid": "79bf0340-ffdb-466c-9259-6dc5218d6227", "name": "4d063cd1-4fff-4f98-8177-f8adbb31c500_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.199673234956728, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.25859312667494616, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "60274c84-23f5-44ff-99e7-ad3b25f47512", "name": "3afce734-0a45-4eba-88ab-17b0dbd76aa7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "79bf0340-ffdb-466c-9259-6dc5218d6227"}}}]}, {"uuid": "4654b7ec-a734-477b-b98c-9cb10503571f", "name": "load_p1rlv18053_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4aeda1c7-41be-43c8-82e5-d7a347db86a8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "60274c84-23f5-44ff-99e7-ad3b25f47512"}}}}, {"uuid": "3e27d3ad-838f-4703-8e56-d400c5f8a3ce", "name": "3fcdee97-11a1-400c-b114-7c40df65b086_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7675749799903273, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6204429178040327, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "958bd145-fde9-484a-acfb-51e25fc3f9c8", "name": "ed7798d9-a2ac-41f6-b2e8-c2c2edac844e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3e27d3ad-838f-4703-8e56-d400c5f8a3ce"}}}]}, {"uuid": "88995c28-9ad6-4253-b4e5-abd41ca9e893", "name": "load_p1rlv18071_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86917829-123c-4fda-9809-dc61430a9fef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "958bd145-fde9-484a-acfb-51e25fc3f9c8"}}}}, {"uuid": "e771654a-ed9a-4ad0-b64e-2fbfa5239ffd", "name": "fa50f85a-044f-49a5-923f-a7bcddb40686_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7675749799903273, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6204429178040327, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b099b994-1dac-48a6-bafa-305c627fe7bd", "name": "34354eae-b6d8-4527-8a04-babf22ff2f34", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e771654a-ed9a-4ad0-b64e-2fbfa5239ffd"}}}]}, {"uuid": "1a472225-fbb8-44a1-b0ef-094c201ca96d", "name": "load_p1rlv18071_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86917829-123c-4fda-9809-dc61430a9fef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b099b994-1dac-48a6-bafa-305c627fe7bd"}}}}, {"uuid": "03075fc0-3dbe-4162-8d65-f42b924a9a81", "name": "cea04c29-238b-4c69-ab2d-8c7e7dd7b301_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2005170978204305, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8833048630127251, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cccf2bd5-fc9b-4b22-ad4f-6e60c8241b9b", "name": "6ca40b0d-06cc-469c-8da4-ce0f4ad063d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "03075fc0-3dbe-4162-8d65-f42b924a9a81"}}}]}, {"uuid": "28148e11-d3f7-4090-99b7-f2914a7771c7", "name": "load_p1rlv18100_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4863d28-4ee2-479d-accb-60b54f472fe7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cccf2bd5-fc9b-4b22-ad4f-6e60c8241b9b"}}}}, {"uuid": "d1cb8122-5757-430c-8855-0127ca1873f2", "name": "27c4cb99-9a24-411d-9960-24b11ac0eaec_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2005170978204305, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8833048630127251, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b05810b3-1268-45d7-9846-95cd0ad29b3c", "name": "5a0826ab-1ad9-460a-9b0c-cd7b6a386ea4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d1cb8122-5757-430c-8855-0127ca1873f2"}}}]}, {"uuid": "33841819-e3a2-4fec-a57f-b1864081f314", "name": "load_p1rlv18100_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4863d28-4ee2-479d-accb-60b54f472fe7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b05810b3-1268-45d7-9846-95cd0ad29b3c"}}}}, {"uuid": "8c72effc-f49a-4c58-ad55-22badf2f583d", "name": "2e352eb8-6201-4c37-ba59-10a9cb0eb2f3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2075389461119934, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3167249782629938, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "986789eb-fe6d-4ef7-840f-e5fcbf1e3bc0", "name": "bde6c827-9d2c-411b-a06d-3ba379010267", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8c72effc-f49a-4c58-ad55-22badf2f583d"}}}]}, {"uuid": "f2cfd818-8882-43e9-addd-e0ad44040a28", "name": "load_p1rlv18129_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "115a848f-f6f3-48f0-9f33-5a9103f1a892"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "986789eb-fe6d-4ef7-840f-e5fcbf1e3bc0"}}}}, {"uuid": "5a2ce607-31a7-40a7-8a80-162bb5787360", "name": "021e46a8-a5d4-4dc6-aa79-874afe956e42_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2075389461119934, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3167249782629938, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e9dab9c4-3f86-4dc0-bf0d-ba3fc0e13621", "name": "4569044e-ce09-49e1-9104-2878e36f1ec2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5a2ce607-31a7-40a7-8a80-162bb5787360"}}}]}, {"uuid": "4dbcd618-27f3-417a-9b1d-07e0894cd8f9", "name": "load_p1rlv18129_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "115a848f-f6f3-48f0-9f33-5a9103f1a892"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e9dab9c4-3f86-4dc0-bf0d-ba3fc0e13621"}}}}, {"uuid": "ed97d495-4878-4728-805d-f857a3a611ec", "name": "fc62f661-92ad-4639-88e3-9dca6a64180c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3268329182243828, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6606620655388332, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "12991d25-4c53-47d7-ab45-adc402c143d3", "name": "736cf412-ac15-4084-8de1-411be757913f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ed97d495-4878-4728-805d-f857a3a611ec"}}}]}, {"uuid": "f1da61cb-3884-4f89-b184-c3708d29eb39", "name": "load_p1rlv18166_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "431692e5-2917-41ea-aafc-96be180b7e27"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "12991d25-4c53-47d7-ab45-adc402c143d3"}}}}, {"uuid": "9d66f1fa-41a6-4581-ab8c-81e89618b04b", "name": "4cdb61f2-3a90-4f0c-ab4c-7a53207cf31a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3268329182243828, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6606620655388332, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d9c8f299-4954-40a4-a240-cd2adae70530", "name": "e14d0abd-926d-4b2e-83f2-6afa1fdc9b5b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9d66f1fa-41a6-4581-ab8c-81e89618b04b"}}}]}, {"uuid": "ebf7542b-7eda-4a54-ab7f-c9324bbf5e8d", "name": "load_p1rlv18166_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "431692e5-2917-41ea-aafc-96be180b7e27"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d9c8f299-4954-40a4-a240-cd2adae70530"}}}}, {"uuid": "ab46062b-f641-4da2-96c8-8c433018dd78", "name": "6972b329-1f10-4ef6-ad40-e76563e89199_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cc9487f5-2aab-43b3-992e-54f57e90d5c8", "name": "a56b133d-f339-48b0-b8e0-08351d898d96", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ab46062b-f641-4da2-96c8-8c433018dd78"}}}]}, {"uuid": "fb84b9e0-2dfe-44a9-a3f1-93c28e583a40", "name": "load_p1rlv18192_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c3e08a8-ea88-423d-b361-69509f7ab8fa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cc9487f5-2aab-43b3-992e-54f57e90d5c8"}}}}, {"uuid": "951d662a-0416-45f2-9997-c6e140565f83", "name": "45acbd5f-b7e8-46f1-a2e5-e99e1003350d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8434317b-50f4-4029-ab69-190b32871133", "name": "640917a0-312a-47c7-b00a-50b0d8a1dbf9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "951d662a-0416-45f2-9997-c6e140565f83"}}}]}, {"uuid": "2b1900a9-e3e5-4074-8d8d-25af0c96225a", "name": "load_p1rlv18192_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c3e08a8-ea88-423d-b361-69509f7ab8fa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8434317b-50f4-4029-ab69-190b32871133"}}}}, {"uuid": "b61f3f55-672b-4cad-aa77-43e4ce9bc1fc", "name": "75ffe928-d893-4390-b50f-05c00ef1ff76_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.948680292874151, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.769988963438003, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4882a0c1-919d-4da2-bc38-44888d427089", "name": "dc460813-a025-4a1b-9de4-26291cf0936d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b61f3f55-672b-4cad-aa77-43e4ce9bc1fc"}}}]}, {"uuid": "a07e8600-88ab-4422-91ff-ca68999aa185", "name": "load_p1rlv18197_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5e240e8-b27d-4181-a7ee-a004d3f5c58a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4882a0c1-919d-4da2-bc38-44888d427089"}}}}, {"uuid": "d0976f00-4aaa-4faa-9f7b-963cf6661a53", "name": "f4ed0f48-252c-4744-a8be-47521bb9e690_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.948680292874151, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.769988963438003, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9b834b4a-d6dd-458e-aa5e-c4b66586c32f", "name": "1d36f195-ab24-4b30-bc04-92e9ff7f7c9e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d0976f00-4aaa-4faa-9f7b-963cf6661a53"}}}]}, {"uuid": "e45885c7-2504-4309-9bf3-26a2709f647b", "name": "load_p1rlv18197_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5e240e8-b27d-4181-a7ee-a004d3f5c58a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9b834b4a-d6dd-458e-aa5e-c4b66586c32f"}}}}, {"uuid": "b44a5637-33ac-43e4-9b88-35bcc319c1f3", "name": "03c05035-fe62-4427-a676-da984a6bb1d9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1698158732703443, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8490689598373361, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7f7cd507-7c9d-44bc-8133-69917dbfc87c", "name": "ea4fc29e-6ff7-42a4-bb90-eab6be3af249", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b44a5637-33ac-43e4-9b88-35bcc319c1f3"}}}]}, {"uuid": "c4fbfa3b-3dc0-41e9-b442-03e16247c0a4", "name": "load_p1rlv18198_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a7cb078-af6c-4cd5-9aca-48f515f6e711"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7f7cd507-7c9d-44bc-8133-69917dbfc87c"}}}}, {"uuid": "e479fb2f-4e22-4c7a-b453-75f36c005814", "name": "50472ce7-6c1e-4b22-83fa-668d103c6d6f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1698158732703443, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8490689598373361, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f4b23009-956b-4690-aabc-ec574695bed0", "name": "69dad363-7f6e-43f7-ba5a-a1783a4cf1a8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e479fb2f-4e22-4c7a-b453-75f36c005814"}}}]}, {"uuid": "1a5ed19a-7d46-43e6-9691-6d3f55153c9f", "name": "load_p1rlv18198_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a7cb078-af6c-4cd5-9aca-48f515f6e711"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f4b23009-956b-4690-aabc-ec574695bed0"}}}}, {"uuid": "276ea94c-e3c1-4cc5-9859-3a79835d1732", "name": "7e861e6f-9889-4f20-a5da-ebcb502d6916_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1801024488747824, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6406661654566495, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "08b7b6d3-4881-4ee5-9ec6-4bfc51ec49ce", "name": "3f5ce7bc-bb23-445c-8e73-acaedd6d90a8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "276ea94c-e3c1-4cc5-9859-3a79835d1732"}}}]}, {"uuid": "299e6517-f4c9-4ce7-9581-76c2055f841a", "name": "load_p1rlv18960_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9178fdee-311f-40f5-bdd6-9b474a05247e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "08b7b6d3-4881-4ee5-9ec6-4bfc51ec49ce"}}}}, {"uuid": "72d93b5a-33ab-47bb-9adb-4ff1c9b299df", "name": "1696a9c2-4c7e-4554-aca7-0a06eb4fdd48_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1801024488747824, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6406661654566495, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "09b995d5-0033-485f-b28a-8760affaac32", "name": "464a37f8-2e6d-4d9c-bb83-37ddc44d0fab", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72d93b5a-33ab-47bb-9adb-4ff1c9b299df"}}}]}, {"uuid": "51ed28f6-fde9-4502-9bde-3b93db46f283", "name": "load_p1rlv18960_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9178fdee-311f-40f5-bdd6-9b474a05247e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "09b995d5-0033-485f-b28a-8760affaac32"}}}}, {"uuid": "899a49e6-7b69-4db2-8d09-8925b0ce3fb1", "name": "8053ebbb-7ea6-4faa-aa26-0b9f67c1feff_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2045141672666357, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3046267940472902, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "51a0facb-5b80-4fbb-9975-cb7581507496", "name": "91d20e8a-8b70-460f-b8fb-8ae972a78dc1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "899a49e6-7b69-4db2-8d09-8925b0ce3fb1"}}}]}, {"uuid": "2f8f440f-bdcc-448e-8f86-8b00ebb2acfc", "name": "load_p1rlv18967_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eef4f0cf-6e51-45e1-8b6e-84171f7cbef6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "51a0facb-5b80-4fbb-9975-cb7581507496"}}}}, {"uuid": "a725c8c0-7954-4257-9a35-a61da37a2e42", "name": "70fcedb9-cf7e-4485-9a0f-9e1e11138e2f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2045141672666357, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3046267940472902, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fe11e8fd-a436-4ca3-bd2b-cc95dca6b5fa", "name": "13bd4487-3d1d-4764-b85b-3eba9ec1eeef", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a725c8c0-7954-4257-9a35-a61da37a2e42"}}}]}, {"uuid": "9cc09d32-0935-4602-a270-cf01750eee4d", "name": "load_p1rlv18967_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eef4f0cf-6e51-45e1-8b6e-84171f7cbef6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fe11e8fd-a436-4ca3-bd2b-cc95dca6b5fa"}}}}, {"uuid": "1bc226e4-d825-48c6-b833-fe32cf0ae345", "name": "177bb8d7-148a-41b3-b2de-a89663e90700_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1222862909492073, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34523553920221683, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "125c1e25-a0ec-48cd-8e28-e7715a931e54", "name": "e722f372-88ba-4e37-8b0a-bd6dc16ffd8b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1bc226e4-d825-48c6-b833-fe32cf0ae345"}}}]}, {"uuid": "2f9a01e1-3bf0-4357-891e-89f0f5382d4b", "name": "load_p1rlv19146_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0bb184ad-cb26-4317-8c40-f2c8a9f80dab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "125c1e25-a0ec-48cd-8e28-e7715a931e54"}}}}, {"uuid": "d34e1d78-8d7c-417c-8892-0c55830d30ab", "name": "ff88758b-f910-4a31-8511-29aa0ed51445_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1222862909492073, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34523553920221683, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1ece6b38-82a3-43f4-84c9-09f1840cdf2b", "name": "a65f33d6-bdcc-4356-a949-430509372f0f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d34e1d78-8d7c-417c-8892-0c55830d30ab"}}}]}, {"uuid": "d93487e0-e966-46e0-8d01-1def495b974d", "name": "load_p1rlv19146_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0bb184ad-cb26-4317-8c40-f2c8a9f80dab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1ece6b38-82a3-43f4-84c9-09f1840cdf2b"}}}}, {"uuid": "69f7dbef-382f-4102-a948-57f2c415c946", "name": "a189b0be-1b52-4fcf-a047-5b79aafa0cb8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4868228207229564, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16976956391895093, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d130eab6-4e26-4eef-a078-d7c0b36a6ffc", "name": "90529770-274c-4c96-bb3b-977a5634b8af", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "69f7dbef-382f-4102-a948-57f2c415c946"}}}]}, {"uuid": "6e5c4f0f-df78-4714-9ce1-7d7261bf01ac", "name": "load_p1rlv19147_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "546433b3-d70e-49ed-9037-ec88adda79b9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d130eab6-4e26-4eef-a078-d7c0b36a6ffc"}}}}, {"uuid": "0a53069c-3064-4f06-872d-870fd265d2c3", "name": "6b8cac3e-b265-423f-8f4f-f24c760d8254_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4868228207229564, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16976956391895093, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "36dc5985-18ba-4e5e-9854-e0c0d806f1f2", "name": "487d7df3-d4f2-4ca3-b2f5-ddc7e6da5c1c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0a53069c-3064-4f06-872d-870fd265d2c3"}}}]}, {"uuid": "f6467e30-51e9-4a90-940c-a4135378cf12", "name": "load_p1rlv19147_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "546433b3-d70e-49ed-9037-ec88adda79b9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "36dc5985-18ba-4e5e-9854-e0c0d806f1f2"}}}}, {"uuid": "e0a27af4-c819-4cc9-9bec-a802754241a8", "name": "61c65a95-d6be-490c-865f-253fc9479b67_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "11b78b7d-430d-4a8d-bef5-0b834f29a3da", "name": "5165893a-7e75-4e7b-bb10-423a322366b4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e0a27af4-c819-4cc9-9bec-a802754241a8"}}}]}, {"uuid": "b4ee36f5-ff72-4a5a-9ce9-8298c7940304", "name": "load_p1rlv19149_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67a4600d-65c3-40d7-ad28-e8e37ff77dcb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "11b78b7d-430d-4a8d-bef5-0b834f29a3da"}}}}, {"uuid": "b126c6f7-d987-4d64-9271-4040e5e45fb2", "name": "411a8146-f899-45ca-9bf0-aab8e89c51e5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1deb3031-dd5d-4979-9be3-b3d7671c2f97", "name": "99cfbb7d-055c-4999-a3f9-841bc2001a22", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b126c6f7-d987-4d64-9271-4040e5e45fb2"}}}]}, {"uuid": "f7ecb440-0f55-4077-972a-53257e3a5828", "name": "load_p1rlv19149_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67a4600d-65c3-40d7-ad28-e8e37ff77dcb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1deb3031-dd5d-4979-9be3-b3d7671c2f97"}}}}, {"uuid": "2006ec6b-bb56-40ed-8a9f-8176087493fb", "name": "c814eae1-c780-4d8c-8f56-b953a77c46d9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9f955821-e89b-4b40-b4a1-6af5dd0b3574", "name": "8bc15210-bb12-457c-8ea0-0edd3dda432d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2006ec6b-bb56-40ed-8a9f-8176087493fb"}}}]}, {"uuid": "447a6f1f-7647-4dcf-9712-01fbb936a123", "name": "load_p1rlv19151_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e396aca-4116-40a0-8f17-bcd41f709ea5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9f955821-e89b-4b40-b4a1-6af5dd0b3574"}}}}, {"uuid": "c4fd19b7-b22f-46e5-b563-0298fb65e63c", "name": "ad996323-23ba-4d5d-b88c-159e5e2cbaaf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c137e1f1-bdbb-49ff-8f40-580b7e0f4224", "name": "ec44ced7-7c3c-4fde-b7fa-6b14d50146c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c4fd19b7-b22f-46e5-b563-0298fb65e63c"}}}]}, {"uuid": "c32a760d-f772-45ff-b58c-786f29590e79", "name": "load_p1rlv19151_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e396aca-4116-40a0-8f17-bcd41f709ea5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c137e1f1-bdbb-49ff-8f40-580b7e0f4224"}}}}, {"uuid": "c979f935-316d-4b43-8d51-0fae19c3ce1f", "name": "fa22fc25-8a81-4d5e-af8a-9ee320db2b53_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "99e06090-15dd-44ff-9d44-643acab3c309", "name": "f015c1fc-bc74-4fcb-a5c5-4c00e9b6e1a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c979f935-316d-4b43-8d51-0fae19c3ce1f"}}}]}, {"uuid": "67d5f06f-741f-4d64-8663-e91765b579ce", "name": "load_p1rlv19156_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7538ab85-10b4-4f60-98f8-179e954173b0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "99e06090-15dd-44ff-9d44-643acab3c309"}}}}, {"uuid": "63861aec-1ad6-4dff-a6b7-8e477408f934", "name": "266481a1-df1e-48ee-ab0c-e02cc76fe11c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5e21c6ee-1022-4216-8086-614971d8d0dc", "name": "bc1f8952-aa82-438a-b2de-7e231781adc7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "63861aec-1ad6-4dff-a6b7-8e477408f934"}}}]}, {"uuid": "9eccf85d-4195-48ef-b3e4-2066df60f2ca", "name": "load_p1rlv19156_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7538ab85-10b4-4f60-98f8-179e954173b0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5e21c6ee-1022-4216-8086-614971d8d0dc"}}}}, {"uuid": "ab78db94-1f0e-4dd7-83d1-9c218fb6c801", "name": "a4afcba3-8368-4025-a240-a48948785ede_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "03f0b66f-8782-437d-893c-4ab306535a7e", "name": "fd9b05bb-cd06-495e-ad6b-02b803e6ef0a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ab78db94-1f0e-4dd7-83d1-9c218fb6c801"}}}]}, {"uuid": "fb7b6520-f031-46e5-ab58-5a32c3720f76", "name": "load_p1rlv19157_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cf28b5d-d8d4-4883-a396-2d1ad9b70564"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "03f0b66f-8782-437d-893c-4ab306535a7e"}}}}, {"uuid": "4aec0a3d-5ed1-4d04-872b-4ea2c9a0270f", "name": "2b8246dc-5e8d-4877-b179-32172f58dbeb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "41a0cbe4-e162-4b07-8626-a429f97eb724", "name": "616828e3-a43b-4bd1-8729-bfc0edf8fea0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4aec0a3d-5ed1-4d04-872b-4ea2c9a0270f"}}}]}, {"uuid": "dfd1c368-60c2-4c49-a3d6-658df1829401", "name": "load_p1rlv19157_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cf28b5d-d8d4-4883-a396-2d1ad9b70564"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "41a0cbe4-e162-4b07-8626-a429f97eb724"}}}}, {"uuid": "656bb808-01e5-498d-b7e6-9d46d58c4339", "name": "e40be9cf-19b0-49f8-91cf-e7ed028086cb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cfb03cdd-df7b-4b87-835c-c55f81af6284", "name": "4b6fcb01-dac6-49ef-86a5-0aa8362e52c5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "656bb808-01e5-498d-b7e6-9d46d58c4339"}}}]}, {"uuid": "8b847b39-7e24-4032-b73b-2d85750c95c6", "name": "load_p1rlv19160_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7c1d210-ee87-46c5-b408-ad221cbeed04"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cfb03cdd-df7b-4b87-835c-c55f81af6284"}}}}, {"uuid": "204671b2-3428-47fe-846a-7027d0e70063", "name": "af954102-ced1-4ef2-aa4d-f783f34441d0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d77f185c-0a07-499e-94e4-504cda314ca5", "name": "355cf035-3998-4d46-9cef-82b52ea8b04f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "204671b2-3428-47fe-846a-7027d0e70063"}}}]}, {"uuid": "56a631ee-ab12-4070-82c8-c6afb5a609eb", "name": "load_p1rlv19160_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7c1d210-ee87-46c5-b408-ad221cbeed04"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d77f185c-0a07-499e-94e4-504cda314ca5"}}}}, {"uuid": "1257114c-fea5-441e-93ad-1e4d27afac16", "name": "5316039a-415e-4595-b908-92332fae7858_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c9e8216b-acd6-40a8-900a-1997fd54b543", "name": "a8fd5c09-0540-4cf1-96f7-2ccc4453783f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1257114c-fea5-441e-93ad-1e4d27afac16"}}}]}, {"uuid": "5e1657e0-b2a4-46b2-9af1-b71e3627f267", "name": "load_p1rlv19161_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16df6b90-d049-4160-b148-b888e03acb82"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c9e8216b-acd6-40a8-900a-1997fd54b543"}}}}, {"uuid": "29918bf7-fa41-4fc0-8435-78a1b354e19e", "name": "1dfbdde7-c939-48ca-ac88-d954a09977c3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8faaf976-ea71-4910-9243-aee1cb5d3875", "name": "90456313-14d1-4cfb-a466-8c19ad4da216", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "29918bf7-fa41-4fc0-8435-78a1b354e19e"}}}]}, {"uuid": "d570bd79-b4de-4cb4-b574-33abb71b1d14", "name": "load_p1rlv19161_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16df6b90-d049-4160-b148-b888e03acb82"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8faaf976-ea71-4910-9243-aee1cb5d3875"}}}}, {"uuid": "ba2ff638-568b-4237-b84f-6b8c4a91bc05", "name": "4cccfcec-862f-4664-bc65-7422e770750e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7930e8d4-bccc-4cf3-ae0f-3a50b581908a", "name": "b97340dc-d707-4767-8f8a-4206a3059695", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ba2ff638-568b-4237-b84f-6b8c4a91bc05"}}}]}, {"uuid": "4dfa51cb-050b-4616-880a-0ee67149a094", "name": "load_p1rlv19163_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fed6fcd4-3c97-4f62-a1a7-0b66394218e1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7930e8d4-bccc-4cf3-ae0f-3a50b581908a"}}}}, {"uuid": "b8d6d56e-9c72-4836-a2df-3cfa8013d452", "name": "7c3bf019-abfc-4bf4-8cf1-e4ee76528b6e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "78416a8d-5298-4100-90be-2e4fbc91d751", "name": "113e1321-cf95-47fb-9d92-56087fa014ad", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b8d6d56e-9c72-4836-a2df-3cfa8013d452"}}}]}, {"uuid": "f3f19601-292b-41de-af2e-8f3b1c6b0ae1", "name": "load_p1rlv19163_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fed6fcd4-3c97-4f62-a1a7-0b66394218e1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "78416a8d-5298-4100-90be-2e4fbc91d751"}}}}, {"uuid": "26aaa96b-786e-465c-a2d1-c8894affa276", "name": "de992046-31fd-456e-98b2-a83d9c206b75_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3913635530264314, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9282144314028667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aba50749-2a23-4445-9c0c-330d4aa4cf87", "name": "de992046-31fd-456e-98b2-a83d9c206b75_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3913635530264314, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9282144314028667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "717e806b-fad7-4a1d-916d-8b9115a4d843", "name": "de992046-31fd-456e-98b2-a83d9c206b75_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3913635530264314, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9282144314028667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b979ccd5-2f40-4746-a988-7df3e6b51ee6", "name": "c19c01a7-bb70-4fbf-a2ef-a87e599a4cc5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "26aaa96b-786e-465c-a2d1-c8894affa276"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aba50749-2a23-4445-9c0c-330d4aa4cf87"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "717e806b-fad7-4a1d-916d-8b9115a4d843"}}}]}, {"uuid": "3d93ef47-7f16-49ac-9061-3becf93bfb2e", "name": "load_p1rlv19164", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a02024b5-aa74-4e07-b043-a7a0e8b3e816"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b979ccd5-2f40-4746-a988-7df3e6b51ee6"}}}}, {"uuid": "44176e23-55fa-417c-9129-d715bc9d37e0", "name": "59d63d88-9fc3-472f-8ae1-7306b898b5b5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ff428f8c-2c3a-46ad-bb5b-4f6b3daa897a", "name": "793c4ce9-ef93-447c-969f-d8e370b4e3dc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "44176e23-55fa-417c-9129-d715bc9d37e0"}}}]}, {"uuid": "c19138fe-01ee-49cb-a8d6-b4871fe9a83d", "name": "load_p1rlv19165_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ebd10471-ab4c-4cb7-a822-a83ef20e9854"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ff428f8c-2c3a-46ad-bb5b-4f6b3daa897a"}}}}, {"uuid": "bd2d7e35-1845-408c-b298-02efde1b9cc8", "name": "30aadc1d-05e6-4d31-8f9e-392ba2a57f56_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5c200c50-9ade-4276-ac85-c37b94497797", "name": "4fe8aa86-072e-40d4-8c13-0a754e43967c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bd2d7e35-1845-408c-b298-02efde1b9cc8"}}}]}, {"uuid": "40f5f2ab-ba0c-40cb-bebf-3a82bfd0403b", "name": "load_p1rlv19165_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ebd10471-ab4c-4cb7-a822-a83ef20e9854"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5c200c50-9ade-4276-ac85-c37b94497797"}}}}, {"uuid": "db3a33cb-eb5f-4d19-8040-6ec5f2a248af", "name": "a0625715-56f8-4fdf-b453-3d7c15955b12_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c91b903a-179b-4b9c-8a91-ca04a45d4c0e", "name": "81bc24f8-de82-433f-8707-28c12fd0084a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "db3a33cb-eb5f-4d19-8040-6ec5f2a248af"}}}]}, {"uuid": "39bbf73a-53c6-4b2b-913c-1c0af0433c80", "name": "load_p1rlv19166_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "994f6392-f4e5-4ff8-9eeb-5849cd035912"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c91b903a-179b-4b9c-8a91-ca04a45d4c0e"}}}}, {"uuid": "8d2ed1ec-5a98-4037-90f6-92b438806eed", "name": "1094c4fe-7f5e-4bc1-a61c-0c9559c421da_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f285ff05-ecb6-4188-8db3-8a067e42b5ee", "name": "18649bc0-1baa-4dee-ab9d-f81face75a14", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8d2ed1ec-5a98-4037-90f6-92b438806eed"}}}]}, {"uuid": "07192b48-5d44-4d05-a633-d35c26bff647", "name": "load_p1rlv19166_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "994f6392-f4e5-4ff8-9eeb-5849cd035912"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f285ff05-ecb6-4188-8db3-8a067e42b5ee"}}}}, {"uuid": "51a86754-b9fd-4736-924c-c05f7f8f24cf", "name": "e0397dfc-2399-4620-a56c-99c8d416d2bc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6733980323267108, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22626974414284334, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50c4c48d-222e-4c54-8b4a-f763bdd5b7ce", "name": "44939ef2-1366-47f1-8979-9355dc7e84ee", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "51a86754-b9fd-4736-924c-c05f7f8f24cf"}}}]}, {"uuid": "e04e6f75-8d46-4726-bc92-bc890f422c32", "name": "load_p1rlv19168_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f8c76ca-40ea-4f7d-8042-66edd484f065"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50c4c48d-222e-4c54-8b4a-f763bdd5b7ce"}}}}, {"uuid": "f3bb7e45-84ac-4e2e-8c6c-125d4bcc1ede", "name": "a8ea18d3-c0a0-4561-80db-be47d3e3b27a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6733980323267108, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22626974414284334, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4e293a52-1321-43e4-986f-ff0fca24cd10", "name": "ebfa6fc3-90e8-4825-b481-5a41ede38177", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f3bb7e45-84ac-4e2e-8c6c-125d4bcc1ede"}}}]}, {"uuid": "29924464-4e3b-4d6c-9dcd-7a76c3a12c3c", "name": "load_p1rlv19168_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f8c76ca-40ea-4f7d-8042-66edd484f065"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4e293a52-1321-43e4-986f-ff0fca24cd10"}}}}, {"uuid": "96ad5f29-86ea-420a-a9cd-cbe7ca2e48eb", "name": "7db4b8c9-b98e-45ba-8a81-e9ce5bd4bb30_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0288569450045768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2608148575838028, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "23503b5a-e59b-4bb1-99f8-1e372e32a039", "name": "62c2d498-c75f-447d-8219-db50186f09b6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "96ad5f29-86ea-420a-a9cd-cbe7ca2e48eb"}}}]}, {"uuid": "e7dff548-5064-438a-a413-9aff670679b5", "name": "load_p1rlv19169_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4e8183-9148-477e-aa1b-ff31a5324273"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "23503b5a-e59b-4bb1-99f8-1e372e32a039"}}}}, {"uuid": "7386bf6b-5ea9-40f9-81d4-65cc62638403", "name": "4b60ec54-5e0c-4c8f-b177-4f0bffa4eab6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0288569450045768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2608148575838028, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b3b308a3-95f6-4303-ba39-ab01f40fb440", "name": "0a6d326f-8727-46a0-ac05-12991b041c50", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7386bf6b-5ea9-40f9-81d4-65cc62638403"}}}]}, {"uuid": "95cd4e39-549f-4256-bf1b-88f6a43ef741", "name": "load_p1rlv19169_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4e8183-9148-477e-aa1b-ff31a5324273"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b3b308a3-95f6-4303-ba39-ab01f40fb440"}}}}, {"uuid": "3e51eee4-c9b9-48b9-a509-6f5d3e28c164", "name": "ccaac138-77af-4e48-916d-b215032ae845_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9179777962446224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3481400399277513, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f5d6c979-9438-4c19-8522-4d45c399fcb9", "name": "88fa76d0-d740-4eb3-8795-a964b43c92f7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3e51eee4-c9b9-48b9-a509-6f5d3e28c164"}}}]}, {"uuid": "3f6ce2c3-d243-479a-a3f8-620a114cebfe", "name": "load_p1rlv19171_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fffe26f7-c4cc-420e-ab17-754cb0d9e659"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f5d6c979-9438-4c19-8522-4d45c399fcb9"}}}}, {"uuid": "d6c1250f-f71d-4f1a-bb72-14dfd31baa8a", "name": "16f46533-7fb7-48d6-a498-b14c5792acee_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9179777962446224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3481400399277513, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6a2bd906-7f88-4096-9f94-b57562a4e999", "name": "1226bbba-e446-4d18-ba7f-61609911329c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d6c1250f-f71d-4f1a-bb72-14dfd31baa8a"}}}]}, {"uuid": "5b046daf-851a-4c1b-bf0d-1ec757448c4d", "name": "load_p1rlv19171_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fffe26f7-c4cc-420e-ab17-754cb0d9e659"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6a2bd906-7f88-4096-9f94-b57562a4e999"}}}}, {"uuid": "f5c47ead-457b-4112-ad8c-4800362713a6", "name": "f3fed72c-794e-4ccf-bc98-1ddfbcffbf3e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2767849318619047, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.48605417385422345, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f0954b2-7595-4880-a85c-16379689a5a3", "name": "1f0ab7cf-00b3-4787-82dd-921330051fe0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f5c47ead-457b-4112-ad8c-4800362713a6"}}}]}, {"uuid": "de37a26e-d354-4d16-9ee2-102d49f9e97c", "name": "load_p1rlv19173_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21fec301-b67c-4042-a074-caf406c7f0b5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f0954b2-7595-4880-a85c-16379689a5a3"}}}}, {"uuid": "2755ca43-8485-4ee8-9f11-17dfc565e8b4", "name": "bf502988-57ea-4c56-817e-faeb9c732a97_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2767849318619047, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.48605417385422345, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "56afcfe9-dd5a-47a8-a53d-ba1dbef8cef0", "name": "c11a0f4c-9a5b-42bf-815d-2910e39bb476", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2755ca43-8485-4ee8-9f11-17dfc565e8b4"}}}]}, {"uuid": "fa66facc-d041-44f5-865d-955b3f553535", "name": "load_p1rlv19173_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21fec301-b67c-4042-a074-caf406c7f0b5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "56afcfe9-dd5a-47a8-a53d-ba1dbef8cef0"}}}}, {"uuid": "a8ae73b7-6e03-45d9-88de-409827be9cba", "name": "c2bd9970-2177-4852-a67c-9100fdfe36c5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4675207102133878, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42773122049615037, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b13a61e3-6de6-4b4d-ac19-c5e0a0b750b2", "name": "a98c29a4-7501-485a-9244-e39748d5e127", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a8ae73b7-6e03-45d9-88de-409827be9cba"}}}]}, {"uuid": "a0c7ea11-2c63-436f-879b-8ec104b8b6af", "name": "load_p1rlv19174_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0fc7d43-4f82-4100-99bf-6e30e03e95ce"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b13a61e3-6de6-4b4d-ac19-c5e0a0b750b2"}}}}, {"uuid": "fce4b9b9-ef25-43db-b488-7c2ccd0c63ed", "name": "827cf8ba-b9b6-4746-bab5-e2cecc2e9125_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4675207102133878, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42773122049615037, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7a4cae4e-d607-441d-8748-6f41ba771bd7", "name": "7fb7b1de-b694-4253-aed5-7dfb0b2b674f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fce4b9b9-ef25-43db-b488-7c2ccd0c63ed"}}}]}, {"uuid": "f84efad9-2336-4892-ac50-8af41feac531", "name": "load_p1rlv19174_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0fc7d43-4f82-4100-99bf-6e30e03e95ce"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7a4cae4e-d607-441d-8748-6f41ba771bd7"}}}}, {"uuid": "e654623f-313c-4b11-9315-ba6f2ef0b77e", "name": "dc4c20ae-4a63-412e-810d-23b4fd6c1190_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4660310317378347, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6643122913958558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "04555b76-290e-4556-b6b5-aa452336de03", "name": "c47057d9-5386-48fb-b604-4f93f2f5d2e1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e654623f-313c-4b11-9315-ba6f2ef0b77e"}}}]}, {"uuid": "061d6c99-a938-4855-b40a-9ef3068c8ecb", "name": "load_p1rlv19183_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "89bde057-807b-415c-9135-267c6bf43c44"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "04555b76-290e-4556-b6b5-aa452336de03"}}}}, {"uuid": "d0c2da70-16d4-4628-b508-621ecdfeeed0", "name": "c4771986-d8bf-440d-9b02-89deba7df031_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4660310317378347, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6643122913958558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6df221e1-7eb3-418c-ae30-18231f96db2c", "name": "4d7441d4-a0b8-4f87-a28f-9cc6381503b8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d0c2da70-16d4-4628-b508-621ecdfeeed0"}}}]}, {"uuid": "8ac36c2a-9eb2-4707-94ab-d7fed5c8d220", "name": "load_p1rlv19183_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "89bde057-807b-415c-9135-267c6bf43c44"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6df221e1-7eb3-418c-ae30-18231f96db2c"}}}}, {"uuid": "b079212d-2bdf-4bca-ae52-116cbe4167c7", "name": "860c4415-3bb1-4dc0-8a44-3322d4fe5bf7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.515259426400046, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4440975656599118, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3d8f19ec-f5a5-40d6-a2dd-707046dd3177", "name": "3c640dd5-a945-4231-8a4f-1bff34e77eb3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b079212d-2bdf-4bca-ae52-116cbe4167c7"}}}]}, {"uuid": "b6de3fac-4d6b-4a52-a9e2-e974cac85e5d", "name": "load_p1rlv19184_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50750ddb-80db-4d5f-bc62-4bbfc600a7ef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3d8f19ec-f5a5-40d6-a2dd-707046dd3177"}}}}, {"uuid": "75f6a9a4-4da0-4ec3-84b7-005556956265", "name": "89105886-e868-4927-8559-64821a385e04_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.515259426400046, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4440975656599118, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "efc0f742-5b1f-43a0-b2d4-5573c1a4d140", "name": "6e84dfc1-a870-431a-a07e-760ec8df0377", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "75f6a9a4-4da0-4ec3-84b7-005556956265"}}}]}, {"uuid": "971cc166-3ac8-4edc-b2a2-3530ffcaff58", "name": "load_p1rlv19184_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50750ddb-80db-4d5f-bc62-4bbfc600a7ef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "efc0f742-5b1f-43a0-b2d4-5573c1a4d140"}}}}, {"uuid": "754642c3-e803-4f34-baff-f09e25515573", "name": "baa45f2f-c3a6-49db-858a-ebdf21e7d73f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4040789998842194, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4565305929598704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5a7516eb-2e14-471b-b1a5-80ff03ee3fa7", "name": "d751e070-701e-4082-850e-878f679e40fa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "754642c3-e803-4f34-baff-f09e25515573"}}}]}, {"uuid": "66f572e4-3523-4380-9a62-0e30fd1a5db1", "name": "load_p1rlv19188_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47e24942-486d-46f1-a40f-0da5c93c013a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5a7516eb-2e14-471b-b1a5-80ff03ee3fa7"}}}}, {"uuid": "dad37bec-9b09-4868-9885-d2bcb994668d", "name": "32b1c83a-d83e-49c3-a245-2eeb2851a00a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4040789998842194, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4565305929598704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8014c6ba-e17d-4245-a9f8-48da6e5f0bd4", "name": "c16b5c3a-cb3c-48ec-80a5-95cc90f22f7b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dad37bec-9b09-4868-9885-d2bcb994668d"}}}]}, {"uuid": "e438f8bd-9345-4a19-a5dd-8239ac819ea3", "name": "load_p1rlv19188_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47e24942-486d-46f1-a40f-0da5c93c013a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8014c6ba-e17d-4245-a9f8-48da6e5f0bd4"}}}}, {"uuid": "7a9d7dc7-316b-40fa-b29f-90498d17c758", "name": "26b13717-8147-43cd-b52a-6d4b427ecf93_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.600795001494098, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2809795860066686, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eecd4421-78a7-416b-a3a3-deaf14e94d32", "name": "8205e059-91bc-4214-a0aa-c7c79f3147f7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7a9d7dc7-316b-40fa-b29f-90498d17c758"}}}]}, {"uuid": "1098ee10-5a4e-4a3c-b15d-d74068a9626a", "name": "load_p1rlv19189_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5fecc64a-4783-4ecb-a0d0-7e60d1cf6184"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eecd4421-78a7-416b-a3a3-deaf14e94d32"}}}}, {"uuid": "b052e304-473c-4eb4-860a-9a0bc656d98c", "name": "5d5bbf5b-4aec-4c9d-8284-8b9c4382b100_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.600795001494098, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2809795860066686, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7b3d9326-cef3-4965-890b-b628e4d53fec", "name": "754cf4af-6527-48c8-95e7-26b2c749a595", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b052e304-473c-4eb4-860a-9a0bc656d98c"}}}]}, {"uuid": "7473f293-ed7f-4335-bafc-5a15171814ac", "name": "load_p1rlv19189_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5fecc64a-4783-4ecb-a0d0-7e60d1cf6184"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7b3d9326-cef3-4965-890b-b628e4d53fec"}}}}, {"uuid": "00b124f3-cc84-430f-97a4-73423875313a", "name": "ceee5312-17ae-4fbf-b3d8-9867944bd18c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0490448796184286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8093782533373945, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "afbf58b1-8dca-4241-b36b-51ca85dc011d", "name": "2a4fd228-46cf-41a5-9624-030a18ec5c56", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "00b124f3-cc84-430f-97a4-73423875313a"}}}]}, {"uuid": "7a57a2de-df82-4671-9dcd-3f69ee3acdfb", "name": "load_p1rlv19190_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4aee02d4-8663-455b-a197-55b6b1470895"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "afbf58b1-8dca-4241-b36b-51ca85dc011d"}}}}, {"uuid": "04f380b5-c1ee-4699-8ded-bef9e45c57bb", "name": "857dc4d5-e612-450a-a93b-fa84a87f8f28_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0490448796184286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8093782533373945, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "006b69f8-f94f-41c8-87f5-22b2ee2e8765", "name": "d9ddc10a-cf53-4859-9d95-35c61f4addc0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "04f380b5-c1ee-4699-8ded-bef9e45c57bb"}}}]}, {"uuid": "7f756e00-95e8-4749-99b7-6533fb0bc45e", "name": "load_p1rlv19190_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4aee02d4-8663-455b-a197-55b6b1470895"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "006b69f8-f94f-41c8-87f5-22b2ee2e8765"}}}}, {"uuid": "7ed29888-5e04-490f-aa78-e62dd67093f3", "name": "a040e458-a970-4c7d-9686-89d2fcbe69ff_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7073298240395912, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.27247283022117846, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a0042c48-29f7-4122-9d41-8e1b226a1fa2", "name": "684f1f72-1aed-481a-bd57-43848c78bb39", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7ed29888-5e04-490f-aa78-e62dd67093f3"}}}]}, {"uuid": "5a6858d9-dc19-4959-bfe2-02bb18b2bb2f", "name": "load_p1rlv19194_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7daa1d3-6249-447d-a260-65de5ec0a470"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a0042c48-29f7-4122-9d41-8e1b226a1fa2"}}}}, {"uuid": "f3072aaf-be87-40e4-84fc-c06c6ea3506e", "name": "a7671389-ac45-4876-be86-4ad168ed35a0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7073298240395912, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.27247283022117846, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ed4e9771-7f88-46a3-a65f-5a9bd2944670", "name": "14dcf3fc-3c25-4d56-801f-913d72d024fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f3072aaf-be87-40e4-84fc-c06c6ea3506e"}}}]}, {"uuid": "bfd4db25-0215-426a-b567-04a4ac298abd", "name": "load_p1rlv19194_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7daa1d3-6249-447d-a260-65de5ec0a470"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ed4e9771-7f88-46a3-a65f-5a9bd2944670"}}}}, {"uuid": "3e86aca5-6aab-4f92-ae50-2bddbb36e1be", "name": "af904d00-c1d6-47a9-8edc-0af7c25654b2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5757409771642927, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7652901499575055, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d9809f00-acc3-4d7e-9b89-1477725e87a3", "name": "e0954155-7e81-40da-9db5-b2d1b498ce7a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3e86aca5-6aab-4f92-ae50-2bddbb36e1be"}}}]}, {"uuid": "eac7a319-9e7b-4f16-ad17-ce684bc7550d", "name": "load_p1rlv19667_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33dcb037-4cc8-480f-aac4-bc95e54e165e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d9809f00-acc3-4d7e-9b89-1477725e87a3"}}}}, {"uuid": "ccde68f5-b039-4bda-ae4c-9efd64edbf23", "name": "b40bf064-50a2-4e66-a1e0-0d7e208df0bc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5757409771642927, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7652901499575055, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d5d225fe-1f02-44a7-9290-99e5d55a6faa", "name": "c8517da0-0aae-4d9e-80d3-b8b25f936384", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ccde68f5-b039-4bda-ae4c-9efd64edbf23"}}}]}, {"uuid": "159a267b-a341-462f-af3b-8d2fa2d7a9d3", "name": "load_p1rlv19667_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33dcb037-4cc8-480f-aac4-bc95e54e165e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d5d225fe-1f02-44a7-9290-99e5d55a6faa"}}}}, {"uuid": "ea589c8f-cc85-4486-a172-dcfb51a011cf", "name": "6ff93963-157c-49bf-808e-721b4befa146_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.539100612527363, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.549143952601146, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ae4c2fae-3337-426c-b97e-93002c961cff", "name": "f70c2f5e-b770-488a-ac4d-23d574d34886", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ea589c8f-cc85-4486-a172-dcfb51a011cf"}}}]}, {"uuid": "dd60ac8b-a84d-40ba-9706-2eefe88e3183", "name": "load_p1rlv19668_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6427f66-2e22-40bb-83f1-2a8b1be9191a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ae4c2fae-3337-426c-b97e-93002c961cff"}}}}, {"uuid": "ef8495a0-4d6b-4995-9400-667c6fe969bb", "name": "9f15c2b1-07cb-41d4-84c2-b17acd8dffbf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.539100612527363, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.549143952601146, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c6c85d9c-f0c9-47a9-9a63-ed573637a24e", "name": "c979cb7e-77c5-47f1-b96d-fba1ec56a04b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ef8495a0-4d6b-4995-9400-667c6fe969bb"}}}]}, {"uuid": "4e059a4d-2a38-4306-845c-491ec42a2875", "name": "load_p1rlv19668_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6427f66-2e22-40bb-83f1-2a8b1be9191a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c6c85d9c-f0c9-47a9-9a63-ed573637a24e"}}}}, {"uuid": "f27f007c-2e11-4bdb-bb7e-100621d0bc49", "name": "44437314-92d0-4a62-9834-4fb8eaae5d2e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4037437915385973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5086059213404144, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b949ff1c-0f56-4d40-a461-22cc4cdac93d", "name": "8bae368a-487c-4de4-831a-d8fc546f342b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f27f007c-2e11-4bdb-bb7e-100621d0bc49"}}}]}, {"uuid": "8a5023e4-c0f5-44a0-a855-3398bd2dc9c9", "name": "load_p1rlv19669_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96d3079a-02f1-4c89-ad75-fd0a438c9cf4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b949ff1c-0f56-4d40-a461-22cc4cdac93d"}}}}, {"uuid": "d33f15fc-edf5-4bfa-a3d5-74552ed68265", "name": "61b541aa-9206-4840-ac4f-706ef534c1f5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4037437915385973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5086059213404144, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "117008e9-c0bf-4cc9-b860-289a2d757b15", "name": "8a0f45ea-92a7-4798-8d8f-ebe97c55be71", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d33f15fc-edf5-4bfa-a3d5-74552ed68265"}}}]}, {"uuid": "a21aa7c8-8062-4e99-a92d-1883e14314dc", "name": "load_p1rlv19669_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96d3079a-02f1-4c89-ad75-fd0a438c9cf4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "117008e9-c0bf-4cc9-b860-289a2d757b15"}}}}, {"uuid": "2603ec16-0540-4eeb-a2cd-701568cc54c0", "name": "179e0570-a4a0-4b27-babd-3f4c9ccc0700_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.308477864741614, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307751830484037, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bb9e05e9-b83a-4c56-868c-c22d46686968", "name": "ccb173c5-314b-446f-99a3-56f5a6f88a2e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2603ec16-0540-4eeb-a2cd-701568cc54c0"}}}]}, {"uuid": "10d06a86-24d8-43c3-be81-9e7524c167b8", "name": "load_p1rlv19675_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0031ab1b-d82d-40a5-b41e-bc6f6cb53069"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bb9e05e9-b83a-4c56-868c-c22d46686968"}}}}, {"uuid": "19e75e2a-07c5-4b8d-9791-c5f455991a2b", "name": "eeea6a3d-a27e-466c-b070-2ecd8d446e1f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.308477864741614, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307751830484037, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d7ca90cb-332d-4801-bedc-06caa0a9d9b9", "name": "69c8d922-d412-4b91-aa6a-1c77f7b1828a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "19e75e2a-07c5-4b8d-9791-c5f455991a2b"}}}]}, {"uuid": "d2997514-1651-4b24-9fbe-70e223296d34", "name": "load_p1rlv19675_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0031ab1b-d82d-40a5-b41e-bc6f6cb53069"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d7ca90cb-332d-4801-bedc-06caa0a9d9b9"}}}}, {"uuid": "3a9b348e-e778-4211-801f-9e6f1d945b9c", "name": "9930f8d0-e7ac-478b-a9f3-6b79645baaaa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4359784649582454, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.14838741475370543, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f5ab5822-1abe-4c20-b73a-0de7d7ba03a1", "name": "ef801244-6147-4689-a91b-878c0eaf26d9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3a9b348e-e778-4211-801f-9e6f1d945b9c"}}}]}, {"uuid": "ad50bdea-72ac-428a-acdf-166a01d5d7af", "name": "load_p1rlv19681_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83afc678-d577-4ef1-afa2-8e3f915a158b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f5ab5822-1abe-4c20-b73a-0de7d7ba03a1"}}}}, {"uuid": "59538ed4-fede-470a-822f-3b8d98eb3227", "name": "29f77274-9da6-4ea5-a124-b6f948542cf6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4359784649582454, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.14838741475370543, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0338d20b-ad9a-42c7-8b29-7ed52185693a", "name": "4a81538b-7048-42c6-b044-9669b84e90c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "59538ed4-fede-470a-822f-3b8d98eb3227"}}}]}, {"uuid": "b3a4b610-473d-4d59-9f38-1d36ac630f13", "name": "load_p1rlv19681_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83afc678-d577-4ef1-afa2-8e3f915a158b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0338d20b-ad9a-42c7-8b29-7ed52185693a"}}}}, {"uuid": "d1d0c3a6-4a7f-400b-a363-43c849f9c524", "name": "66047564-508a-4cec-b8ce-63f7ef123416_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4849313480010438, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7277224910757479, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "77941e17-d559-4b1f-b3a3-600923300a63", "name": "3935ff4f-cb25-4218-b2e7-8cd01e2a9328", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d1d0c3a6-4a7f-400b-a363-43c849f9c524"}}}]}, {"uuid": "10735e5a-5755-40a0-8e82-1d583800ddcd", "name": "load_p1rlv19682_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "811acd48-b61c-4a42-b76e-f995961c450e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "77941e17-d559-4b1f-b3a3-600923300a63"}}}}, {"uuid": "fe7d7d58-2846-4202-8450-e78c57fe55f0", "name": "67b3f1c5-2afe-4529-a0f5-ef4b9c245518_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4849313480010438, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7277224910757479, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "42a267db-803a-4bc8-a40d-d8ab8ee7b199", "name": "7fc602c6-9be3-4295-b436-83f2fc0ea5e2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fe7d7d58-2846-4202-8450-e78c57fe55f0"}}}]}, {"uuid": "53946547-2e1c-4c77-a55f-c649d926f97d", "name": "load_p1rlv19682_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "811acd48-b61c-4a42-b76e-f995961c450e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "42a267db-803a-4bc8-a40d-d8ab8ee7b199"}}}}, {"uuid": "d26bc30f-0158-4c51-917f-c60ce491b3fb", "name": "b8d0cf34-a770-4338-910b-adc97ba3d421_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2440101223346245, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10648703060010346, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1acdbbdd-5dcb-4b9e-9a4e-5bc71457e53d", "name": "a127345d-9a3b-48db-bf79-acbad49eb2aa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d26bc30f-0158-4c51-917f-c60ce491b3fb"}}}]}, {"uuid": "1ed25cf3-552c-44cd-b511-1701113ba3c8", "name": "load_p1rlv19686_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47f5777d-2c8d-48c2-bf28-386f3f3dbac4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1acdbbdd-5dcb-4b9e-9a4e-5bc71457e53d"}}}}, {"uuid": "af93eee8-f9bb-442b-a583-01f70afd4be2", "name": "6d593d1f-33a6-427a-b162-895b1023099a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2440101223346245, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10648703060010346, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "65e22d17-96fc-4665-886e-7e790749b309", "name": "303f0c22-2214-43e0-8822-e0bf37a2d074", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "af93eee8-f9bb-442b-a583-01f70afd4be2"}}}]}, {"uuid": "edfb7a27-0781-491e-8b2c-05146ed035ea", "name": "load_p1rlv19686_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47f5777d-2c8d-48c2-bf28-386f3f3dbac4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "65e22d17-96fc-4665-886e-7e790749b309"}}}}, {"uuid": "8a3bd121-0a2f-44af-8082-f24496c7efe4", "name": "048758ca-e638-4bfd-8d21-93557dbc8592_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.895690985965537, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9400572249599172, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "80125096-6207-409a-b0d9-669647c2319a", "name": "08ab45e8-b3a6-4390-a198-d173f57dec21", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a3bd121-0a2f-44af-8082-f24496c7efe4"}}}]}, {"uuid": "5305c7c6-d109-4a09-b2a2-f92de08df8bd", "name": "load_p1rlv19689_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "578b5df8-1dd8-41d9-b6dc-db75db5b115e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "80125096-6207-409a-b0d9-669647c2319a"}}}}, {"uuid": "69ac157c-6e9f-4962-b7cd-69c3655c9828", "name": "bc38a9b4-53f4-432b-a1d0-61ccee37928b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.895690985965537, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9400572249599172, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "43567337-5bcb-4f0c-8318-114fb73d774a", "name": "b7bfa72b-5be3-4ee8-98c8-62cfb2e5ba89", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "69ac157c-6e9f-4962-b7cd-69c3655c9828"}}}]}, {"uuid": "54029791-40d2-46d2-b363-b156e77814c3", "name": "load_p1rlv19689_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "578b5df8-1dd8-41d9-b6dc-db75db5b115e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "43567337-5bcb-4f0c-8318-114fb73d774a"}}}}, {"uuid": "c165eb8f-b5a6-4e6d-9104-35e132a992cc", "name": "c3532b3a-9e3e-417c-9ee3-307cd4b961fd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.308477864741614, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307751830484037, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1b649937-0e7f-494f-b253-419d69e74bab", "name": "76d649ac-cd9e-4f5c-8296-c2ba742698b1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c165eb8f-b5a6-4e6d-9104-35e132a992cc"}}}]}, {"uuid": "c66fa230-0cb1-48ff-ae1e-b329cd193928", "name": "load_p1rlv19690_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2709a70-1a7d-454c-90fd-377e416a0071"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1b649937-0e7f-494f-b253-419d69e74bab"}}}}, {"uuid": "4e74008a-5710-4b3a-b8df-8f73b24776d4", "name": "0347b171-ddc6-480b-8f2e-881491975645_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.308477864741614, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307751830484037, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8b8100cd-4d06-4016-874c-663fb29a2a84", "name": "e0c941a5-31a2-43c6-8d2c-7bab3fe96d52", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4e74008a-5710-4b3a-b8df-8f73b24776d4"}}}]}, {"uuid": "f5b02566-069f-4c58-a0a6-5eed94d9e47c", "name": "load_p1rlv19690_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2709a70-1a7d-454c-90fd-377e416a0071"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8b8100cd-4d06-4016-874c-663fb29a2a84"}}}}, {"uuid": "77165c56-c89d-4ebb-ad57-9b1e28126383", "name": "48fa7aea-32e0-4c8a-bbd1-1cebf6f5d9b6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5901541038441702, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.07457634724192848, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fc34bb05-87f4-4799-a01d-3927f582bcd6", "name": "34f24218-15e1-4f5c-9d09-301a0c1f76cb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "77165c56-c89d-4ebb-ad57-9b1e28126383"}}}]}, {"uuid": "9b820f03-083c-4edf-81ea-27dfe2aee5e5", "name": "load_p1rlv19691_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "604cb559-0f18-4ef7-8bcd-a07a7e7f96d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fc34bb05-87f4-4799-a01d-3927f582bcd6"}}}}, {"uuid": "3a4a5f53-1e04-402a-a6db-3045fa896c82", "name": "788da8c3-0c69-4a0a-8924-972af172aebf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5901541038441702, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.07457634724192848, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "58a9b220-c202-49b7-be70-961245a29423", "name": "05b00e44-bc66-4e6e-a026-9cdc0e5901ac", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3a4a5f53-1e04-402a-a6db-3045fa896c82"}}}]}, {"uuid": "88111d81-0056-4c62-8fa1-ad8367b8b2d7", "name": "load_p1rlv19691_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "604cb559-0f18-4ef7-8bcd-a07a7e7f96d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "58a9b220-c202-49b7-be70-961245a29423"}}}}, {"uuid": "cf87f2b7-175d-4ce8-84c5-e47d6819cd32", "name": "f611a5d7-dea6-405a-9320-609bc39ca2c3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.424079283052672, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.088828085193726, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "28d0d815-3de0-490c-94ae-4c4fa92969da", "name": "f40f87e8-d79c-4aea-a77f-fe8f67002d74", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cf87f2b7-175d-4ce8-84c5-e47d6819cd32"}}}]}, {"uuid": "620421db-9084-49f1-afa1-15b5180d2e9d", "name": "load_p1rlv19692_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b10b272a-2efb-4e19-9921-d4081fb45778"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "28d0d815-3de0-490c-94ae-4c4fa92969da"}}}}, {"uuid": "6201eba7-27e1-4bfa-9236-6be455ae382f", "name": "874ea8ba-2e4a-4758-8910-ffb5aba63a6d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.424079283052672, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.088828085193726, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8fc451d1-1b3a-4027-b6e4-5ab4e353ac33", "name": "c428ca70-9ec6-42e4-9498-df2ce9a9ac01", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6201eba7-27e1-4bfa-9236-6be455ae382f"}}}]}, {"uuid": "89953e12-96e9-494d-a5bc-45969cf03417", "name": "load_p1rlv19692_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b10b272a-2efb-4e19-9921-d4081fb45778"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8fc451d1-1b3a-4027-b6e4-5ab4e353ac33"}}}}, {"uuid": "3e120d1d-e367-4433-8b5c-5cfa4c05bfc7", "name": "c623f11b-f702-4be1-b6b2-d417ae367f0e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.01164824929789, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.30321095330991316, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8e3290d6-521b-4a69-9aa7-a5478a53a9a7", "name": "54f4d3c8-6a3a-4744-a32c-5dacea40d4b8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3e120d1d-e367-4433-8b5c-5cfa4c05bfc7"}}}]}, {"uuid": "98a8d7ce-fa0d-4b53-b172-4c1b6aba6bf7", "name": "load_p1rlv19695_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35fe21a1-f817-426e-9e42-f1f33876dd7d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8e3290d6-521b-4a69-9aa7-a5478a53a9a7"}}}}, {"uuid": "eec4bf16-f1ed-4404-8554-8574940fe947", "name": "272ae202-08fa-4d80-839a-9a3080a1e95f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.01164824929789, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.30321095330991316, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7f95e30e-ea29-451d-87fb-c069d649283a", "name": "6493fce6-8465-4769-9eee-2221707dc58f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eec4bf16-f1ed-4404-8554-8574940fe947"}}}]}, {"uuid": "c20c99cb-c78e-4ae5-aa2e-2accbced38cf", "name": "load_p1rlv19695_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35fe21a1-f817-426e-9e42-f1f33876dd7d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7f95e30e-ea29-451d-87fb-c069d649283a"}}}}, {"uuid": "f145327e-2162-42b6-8a11-26b2bfde7600", "name": "a9857ff6-34b2-4ec8-843b-b4f93dab0a28_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.445994317964332, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8597073331859654, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0c3432cf-d00e-420c-ad29-b45eceacc58a", "name": "632e3014-86c5-401b-9e6a-ea8235b3a564", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f145327e-2162-42b6-8a11-26b2bfde7600"}}}]}, {"uuid": "e7c985a2-dd3e-4ea6-a120-8c6d8e866d63", "name": "load_p1rlv19698_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14b1ab4e-b22d-4a98-8131-fc72c923c735"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0c3432cf-d00e-420c-ad29-b45eceacc58a"}}}}, {"uuid": "b8c806b8-d2d3-4b6e-9b57-3cb8b968f85c", "name": "d51b1bd3-7852-492c-a51e-5ca1e90b38b4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.445994317964332, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8597073331859654, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6354f900-88a1-49f8-bd70-306ee4e16e14", "name": "0a0e1126-55ca-455d-8658-67827e307025", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b8c806b8-d2d3-4b6e-9b57-3cb8b968f85c"}}}]}, {"uuid": "a9fe8784-2888-44a7-afa3-24d828418cda", "name": "load_p1rlv19698_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14b1ab4e-b22d-4a98-8131-fc72c923c735"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6354f900-88a1-49f8-bd70-306ee4e16e14"}}}}, {"uuid": "f317c62a-0a34-4e0b-bffb-508a05b0080c", "name": "162071be-39d3-423a-9165-bfd64e018cd2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4663769608466568, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5502546109327153, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fc82c7e2-b64e-46ce-ac11-0609a93d3242", "name": "ca1e6878-747f-48b5-aafb-2e7baf793657", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f317c62a-0a34-4e0b-bffb-508a05b0080c"}}}]}, {"uuid": "888dbe4f-cd30-4381-bcec-a643f2c74829", "name": "load_p1rlv19699_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48654a82-ac11-4542-94ec-8f731138e1a8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fc82c7e2-b64e-46ce-ac11-0609a93d3242"}}}}, {"uuid": "462bcf4f-c7e0-42f4-b852-f1a30a0b2a49", "name": "678cde70-2782-44ef-94fa-676fc2adb482_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4663769608466568, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5502546109327153, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cf65c499-b81c-4756-b5fc-cb82c815f025", "name": "f57da8ee-9669-44e5-b79d-404a52a01290", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "462bcf4f-c7e0-42f4-b852-f1a30a0b2a49"}}}]}, {"uuid": "fbe73a3c-692a-4ac9-851d-923425420048", "name": "load_p1rlv19699_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48654a82-ac11-4542-94ec-8f731138e1a8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cf65c499-b81c-4756-b5fc-cb82c815f025"}}}}, {"uuid": "179a4141-de77-4c08-a44c-94bc38111e71", "name": "b8edef17-753c-4640-ac88-234b59bd56b6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.331677082668279, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10958157805626084, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "de6c7d43-35c0-417e-9fbd-95f4c1c8135d", "name": "757edf94-1466-40b6-96a7-ca913b133456", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "179a4141-de77-4c08-a44c-94bc38111e71"}}}]}, {"uuid": "4e5e96cb-f1a5-43fa-93cb-23867576491d", "name": "load_p1rlv19701_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b5d936f-b3e0-408e-aabd-d3ebb7b869b0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "de6c7d43-35c0-417e-9fbd-95f4c1c8135d"}}}}, {"uuid": "240b3ec9-bc79-4c17-a8ee-8a8a425aa703", "name": "a68403b6-c7d7-45d0-83a6-4cfb97dc1f03_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.331677082668279, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10958157805626084, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c529a6f8-27f2-45db-aa1e-b8735c436127", "name": "928f825a-6ba2-4c81-a7c3-16861b88d2fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "240b3ec9-bc79-4c17-a8ee-8a8a425aa703"}}}]}, {"uuid": "51fa4197-1ba0-4eb2-b976-cb70045c9dfc", "name": "load_p1rlv19701_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b5d936f-b3e0-408e-aabd-d3ebb7b869b0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c529a6f8-27f2-45db-aa1e-b8735c436127"}}}}, {"uuid": "156a0ac9-458f-4c46-a04e-17ab1c6a23b4", "name": "932c9135-e467-4500-aee5-e3c7f125befa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 10.082274628538993, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.081607403669262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "326677db-6a41-4e8b-980e-90d10d1b78e7", "name": "60006b6a-3bcf-4371-a609-3fc2fb90e38a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "156a0ac9-458f-4c46-a04e-17ab1c6a23b4"}}}]}, {"uuid": "f9d708c9-eff7-4751-bcfa-65f0229b06c6", "name": "load_p1rlv19702_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37f72c85-61f7-4a42-94b0-6a627195458c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "326677db-6a41-4e8b-980e-90d10d1b78e7"}}}}, {"uuid": "42ff104e-d487-488b-8198-ae0df3abe8a3", "name": "6210e0b1-6210-4b7e-ab87-a9bed2bc7dc2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 10.082274628538993, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.081607403669262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0bdc9d7e-fba8-49d4-9a57-658e2eb6cdd9", "name": "c227d2e3-0c90-4d1c-8c71-cc21d84664af", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "42ff104e-d487-488b-8198-ae0df3abe8a3"}}}]}, {"uuid": "6c4ddb26-7f82-4578-95a1-80c652ba322a", "name": "load_p1rlv19702_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37f72c85-61f7-4a42-94b0-6a627195458c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0bdc9d7e-fba8-49d4-9a57-658e2eb6cdd9"}}}}, {"uuid": "3184dfb6-fe85-425b-8a2c-c8fcabee3cd9", "name": "434fc340-de1b-4a82-8747-2248052d2c85_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3786182488338723, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5359363058124609, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b2355f90-4b19-4f76-80f4-adbeb95f2861", "name": "e61cb651-ad75-433a-9e9b-e9b2fda0facc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3184dfb6-fe85-425b-8a2c-c8fcabee3cd9"}}}]}, {"uuid": "dd16986e-9178-4da5-94b5-abcd4a1cc80e", "name": "load_p1rlv20064_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aaea76fa-797e-46c5-a70f-a973977db841"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b2355f90-4b19-4f76-80f4-adbeb95f2861"}}}}, {"uuid": "3feb125e-0d30-4fa3-82b5-0a90a68f4f14", "name": "875ba8f6-e4f4-4981-89ed-f27d39ef2d03_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3786182488338723, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5359363058124609, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "faf06bc4-7f26-4a7b-981a-687b60237334", "name": "d62f7ca0-6d08-4cd6-8386-a2ad5803c0a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3feb125e-0d30-4fa3-82b5-0a90a68f4f14"}}}]}, {"uuid": "57d2795d-d45e-4749-ac18-4571bed715e7", "name": "load_p1rlv20064_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aaea76fa-797e-46c5-a70f-a973977db841"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "faf06bc4-7f26-4a7b-981a-687b60237334"}}}}, {"uuid": "697fca7f-f900-4399-9c9d-b7205ca2b896", "name": "1d1f1f6b-373d-428a-802b-e75f3af3d344_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9024769844937937, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4778358547008617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c89f6f9b-6be1-4081-a28f-ed71a35d83d4", "name": "81dd230b-be00-4e12-8599-9ff89e8d8aeb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "697fca7f-f900-4399-9c9d-b7205ca2b896"}}}]}, {"uuid": "f79d6824-33e0-4ddd-951e-c7a5dac2dc56", "name": "load_p1rlv20065_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea48ffa1-bdb3-4c15-96c9-ff7d7f34824f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c89f6f9b-6be1-4081-a28f-ed71a35d83d4"}}}}, {"uuid": "ad82f3f6-4fb0-493e-93e1-77619dfd382d", "name": "3e63e9a2-9263-49c9-8ce1-3b47b443769f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9024769844937937, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4778358547008617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "73056679-3214-4d0f-83d7-ea183b641d86", "name": "bbc86f6c-acca-45bc-b5c8-5c8e39c6bde2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ad82f3f6-4fb0-493e-93e1-77619dfd382d"}}}]}, {"uuid": "3fa11059-f23c-4332-afc5-f519c6bc4dfa", "name": "load_p1rlv20065_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea48ffa1-bdb3-4c15-96c9-ff7d7f34824f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "73056679-3214-4d0f-83d7-ea183b641d86"}}}}, {"uuid": "82613dda-2b0e-4576-ae18-3bae3f4b0bc1", "name": "12d6d0c1-1c78-4fba-80b4-98cd493320f6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9149869461814677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5767582022429075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "785fa984-c159-4e43-95ba-4838988535f5", "name": "33e33e39-b784-4951-a35e-45fe11e0de3a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "82613dda-2b0e-4576-ae18-3bae3f4b0bc1"}}}]}, {"uuid": "c8b6dbe3-fffb-47f6-b40d-5d02da5b6d2b", "name": "load_p1rlv20066_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f450eeb4-3d87-4ae5-a6d6-958d7efd2712"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "785fa984-c159-4e43-95ba-4838988535f5"}}}}, {"uuid": "173dc49f-cf27-46a6-9b3c-0c661da60210", "name": "5bc0a30a-237a-4fd5-8bc2-85472c196b45_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9149869461814677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5767582022429075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f540a76d-b5bb-431a-b2f2-50d5e78ab247", "name": "378ad036-0bbd-4070-b526-a3133b72d989", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "173dc49f-cf27-46a6-9b3c-0c661da60210"}}}]}, {"uuid": "db1b57aa-7de9-440d-883d-9651cdeae0a4", "name": "load_p1rlv20066_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f450eeb4-3d87-4ae5-a6d6-958d7efd2712"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f540a76d-b5bb-431a-b2f2-50d5e78ab247"}}}}, {"uuid": "2e8cf59c-6701-435e-8544-46ba106c78c7", "name": "8033911c-8184-4264-a0e0-42e5f03c32bf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1800d4d6-8a1e-44bf-ad2f-c6feda9f0b59", "name": "d8ec233b-e55b-463f-83ae-b0ae42abe0e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2e8cf59c-6701-435e-8544-46ba106c78c7"}}}]}, {"uuid": "1e865edd-ffaa-43ba-8b6e-a1d20c8ff803", "name": "load_p1rlv20067_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66a710fb-26c7-4465-b7ea-43ec107008dc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1800d4d6-8a1e-44bf-ad2f-c6feda9f0b59"}}}}, {"uuid": "92818016-ab6d-4337-8604-dcd511bd4151", "name": "2b659a4c-5e5c-44b8-96c0-52aac0b9da6c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a6c90a3d-94da-42ea-be63-43fde770dfde", "name": "f4b0e80f-9d14-4c13-8d38-047e9c58748d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "92818016-ab6d-4337-8604-dcd511bd4151"}}}]}, {"uuid": "7b858e2b-5879-4899-adc7-9d076a7f0ef4", "name": "load_p1rlv20067_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66a710fb-26c7-4465-b7ea-43ec107008dc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a6c90a3d-94da-42ea-be63-43fde770dfde"}}}}, {"uuid": "7677d201-3380-417a-9a52-9ef8fa9dfee1", "name": "63199bcf-5a1a-47bc-8d0a-44308165240b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9909c8b7-5b23-4575-9321-50732255db2a", "name": "3b9e654b-3b09-4b7c-b5b8-3f4660f31a85", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7677d201-3380-417a-9a52-9ef8fa9dfee1"}}}]}, {"uuid": "4152a1b5-d3f7-42db-9171-67392eaf7efd", "name": "load_p1rlv20068_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0b689f0-d4b1-4419-bff8-f72436625c60"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9909c8b7-5b23-4575-9321-50732255db2a"}}}}, {"uuid": "3e63513a-bb72-4d31-a2f9-70ec25c0b612", "name": "9b4bfbff-5ae6-4715-abfa-3af5790cc2d2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8943da66-5e87-482c-b323-437b555f1300", "name": "e7d84638-533e-4bd0-ae06-10a0dd73c4ab", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3e63513a-bb72-4d31-a2f9-70ec25c0b612"}}}]}, {"uuid": "3a0d0e67-4e45-466a-a48b-e5f651e188f6", "name": "load_p1rlv20068_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0b689f0-d4b1-4419-bff8-f72436625c60"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8943da66-5e87-482c-b323-437b555f1300"}}}}, {"uuid": "5605eca0-70bb-4c8b-956a-95ff334d8a43", "name": "f301133a-2df9-4eaf-80fe-f3b6c5d7880f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4037437915385973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5086059213404144, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "273da72e-70f8-4e20-b811-1d5aa8ac1840", "name": "f6722d02-839c-40da-add4-3dd5022b89e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5605eca0-70bb-4c8b-956a-95ff334d8a43"}}}]}, {"uuid": "efba0dc4-178b-4e97-82ec-7abb378997a4", "name": "load_p1rlv20069_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f0e3c74-2d63-4612-b0e5-d986ebee0086"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "273da72e-70f8-4e20-b811-1d5aa8ac1840"}}}}, {"uuid": "d8cb5421-7324-4513-b981-cd8ecdbea96f", "name": "27462fda-ccf8-499d-9b18-ca37ec941ee7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4037437915385973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5086059213404144, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1988d2a9-1029-4430-9f27-d5a16a35948c", "name": "9e4309a5-8321-4913-b06e-df37e6c2ff78", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d8cb5421-7324-4513-b981-cd8ecdbea96f"}}}]}, {"uuid": "398b0ec5-319c-4b3a-acb2-211ad4bd8015", "name": "load_p1rlv20069_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f0e3c74-2d63-4612-b0e5-d986ebee0086"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1988d2a9-1029-4430-9f27-d5a16a35948c"}}}}, {"uuid": "3ba36142-8efd-4af0-aabe-3d6c4e896e98", "name": "19143221-bbf3-412f-a922-844fb1f84b47_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1342890945582846, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10427649324668606, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4beddc3f-4f50-4de9-98bd-a0a3c47d55bb", "name": "420dc19a-c423-4269-929b-8e02f608bb34", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3ba36142-8efd-4af0-aabe-3d6c4e896e98"}}}]}, {"uuid": "ea4428f7-8e83-4552-88eb-60da17163578", "name": "load_p1rlv20070_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "571a4c92-95b6-4bc0-a25d-0d9239a41a89"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4beddc3f-4f50-4de9-98bd-a0a3c47d55bb"}}}}, {"uuid": "70456e11-39d7-47ac-b13e-e03e80311b70", "name": "3281dec8-098a-4ae7-be46-083646516e30_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1342890945582846, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10427649324668606, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4afa5e1a-3342-4e5a-83e8-598613d982bc", "name": "55e58dec-bb57-497a-b7ce-60d7f8574200", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "70456e11-39d7-47ac-b13e-e03e80311b70"}}}]}, {"uuid": "bc306be1-27e3-49cd-a6f3-ed5053de4e79", "name": "load_p1rlv20070_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "571a4c92-95b6-4bc0-a25d-0d9239a41a89"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4afa5e1a-3342-4e5a-83e8-598613d982bc"}}}}, {"uuid": "5f5aa3ad-0611-4475-ac97-843774f3e43a", "name": "388bb2a2-2f73-4610-b003-0829cde0cc95_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.025235929487997, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.9672019739719726, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "497e18cb-741a-46d2-93b0-dcb6dfbbb0ee", "name": "3810dbc5-14a3-413a-9555-92bd8326934b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5f5aa3ad-0611-4475-ac97-843774f3e43a"}}}]}, {"uuid": "6fddd001-4af1-4f25-86b8-830cf26fd999", "name": "load_p1rlv20071_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07f95ba5-92dd-465f-a38d-8e878243262b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "497e18cb-741a-46d2-93b0-dcb6dfbbb0ee"}}}}, {"uuid": "badae621-2271-4fbb-92b9-b7997198bc09", "name": "91f81205-3a31-4aeb-9c65-2bdb639fdc05_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.025235929487997, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.9672019739719726, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "686825c9-98a4-4205-ad4f-b655f3770986", "name": "be7d6cf5-80ec-45c1-9e63-37840f8f0eb5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "badae621-2271-4fbb-92b9-b7997198bc09"}}}]}, {"uuid": "09ab72cc-9134-4f4c-9d62-e7368620535e", "name": "load_p1rlv20071_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07f95ba5-92dd-465f-a38d-8e878243262b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "686825c9-98a4-4205-ad4f-b655f3770986"}}}}, {"uuid": "29885444-289e-4567-ac79-716f71b96499", "name": "d6cacb35-de42-4a55-960a-d2fcc20768b0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7653657521185364, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4426471780914222, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "23605292-f6c1-413b-959f-537dfae499e0", "name": "eb57cc4b-8ee1-44ab-a060-0031eb2d1e1a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "29885444-289e-4567-ac79-716f71b96499"}}}]}, {"uuid": "ea97d3d0-d113-42a9-8f4c-98ccd4431741", "name": "load_p1rlv20130_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ffc82be6-f3f8-4a68-b6e6-da60b137329c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "23605292-f6c1-413b-959f-537dfae499e0"}}}}, {"uuid": "628949c4-d977-44b9-83b5-dfc1b83a448b", "name": "a30ce11a-0069-4dc4-9a77-50344fff2ff4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7653657521185364, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4426471780914222, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a61035e4-5d72-4fb3-9918-8fd2bea3a19e", "name": "a97b7f72-290e-4cc7-942a-142650c7bd59", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "628949c4-d977-44b9-83b5-dfc1b83a448b"}}}]}, {"uuid": "814285a8-0508-4c27-b4cd-6e37590517af", "name": "load_p1rlv20130_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ffc82be6-f3f8-4a68-b6e6-da60b137329c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a61035e4-5d72-4fb3-9918-8fd2bea3a19e"}}}}, {"uuid": "37974511-b79e-4aa4-925a-ae52e6643350", "name": "02ac4d7e-f9c1-4888-8e64-96658f31aa7a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1976836424562762, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1051220183522544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "19a3a383-8f39-431d-a32e-0dfac9c66e47", "name": "4716de37-396d-4f84-9047-19015fc4b6f4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "37974511-b79e-4aa4-925a-ae52e6643350"}}}]}, {"uuid": "67877203-07fb-4971-969c-ca1db78cc7c1", "name": "load_p1rlv20138_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d635a151-2d13-47e9-8043-a214415a5b5e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "19a3a383-8f39-431d-a32e-0dfac9c66e47"}}}}, {"uuid": "329f48ca-3283-47e6-9989-c954e7417b71", "name": "f51afa32-de0f-47ab-a4c2-33c692d05346_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1976836424562762, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1051220183522544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "231b0252-b3b4-443d-99cc-1d0e0bb83657", "name": "e5aa4617-1d5e-460f-9043-0d7d915adec8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "329f48ca-3283-47e6-9989-c954e7417b71"}}}]}, {"uuid": "68a7350c-507f-4869-8bad-6bd0a7069723", "name": "load_p1rlv20138_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d635a151-2d13-47e9-8043-a214415a5b5e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "231b0252-b3b4-443d-99cc-1d0e0bb83657"}}}}, {"uuid": "77e49f4b-b3d3-40b3-834f-4c5168226a08", "name": "5fd864fc-b3a0-438c-9346-f231f66958a9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.839175601618853, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4557221316666175, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "78eab5a8-b3fc-48e7-ac43-fd2dd2da903e", "name": "1f056fd1-addf-4713-8e1b-327857a8743d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "77e49f4b-b3d3-40b3-834f-4c5168226a08"}}}]}, {"uuid": "0667c28e-dd8f-4765-b149-bc0a11a22f81", "name": "load_p1rlv20146_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d615e93-a289-41ec-bda0-3b72bf15677e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "78eab5a8-b3fc-48e7-ac43-fd2dd2da903e"}}}}, {"uuid": "506ef5e7-43e3-4523-9e28-9b4722bf0634", "name": "428b8f72-9bcb-4e02-98fc-1659b2b540e2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.839175601618853, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4557221316666175, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c30682c8-b30f-44c9-908c-fc579a66c330", "name": "1fcbb4ac-279f-46a5-868c-3e5365b9bcc8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "506ef5e7-43e3-4523-9e28-9b4722bf0634"}}}]}, {"uuid": "9b0e659d-e509-4ce2-ba46-cca8bfc2a219", "name": "load_p1rlv20146_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d615e93-a289-41ec-bda0-3b72bf15677e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c30682c8-b30f-44c9-908c-fc579a66c330"}}}}, {"uuid": "8e9732f9-6379-4fd0-ac97-9181c8e829d9", "name": "03898ed5-122c-4c49-b780-cd35835216b3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "afd04a47-3d32-4c66-a95c-2d82fcf9cb75", "name": "913241c2-4cb9-4656-aa6f-c928a21d86df", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8e9732f9-6379-4fd0-ac97-9181c8e829d9"}}}]}, {"uuid": "536437b6-5ff9-472d-a83d-fb5675e57c4a", "name": "load_p1rlv20147_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16b2add7-6a6d-4359-ad6f-f60edf435a4c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "afd04a47-3d32-4c66-a95c-2d82fcf9cb75"}}}}, {"uuid": "3731ebe0-ebd8-47e6-9f23-11292962762b", "name": "76137a33-2e13-4efa-aa08-b7f3288379e1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dc3fa00c-5670-4fcc-914d-cb2e2c2380c9", "name": "6048944f-1622-4c7a-9d8b-15c68d67f7dc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3731ebe0-ebd8-47e6-9f23-11292962762b"}}}]}, {"uuid": "598879fc-5988-40ba-b8b1-b7f009c0bd4b", "name": "load_p1rlv20147_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16b2add7-6a6d-4359-ad6f-f60edf435a4c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dc3fa00c-5670-4fcc-914d-cb2e2c2380c9"}}}}, {"uuid": "f10a8db9-e4a7-409d-9fe0-0a9c827524fe", "name": "d2ab8b89-50f4-4fe5-b697-631e8ee4a2bb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7025097104959883, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.553651846257773, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "09f7234d-2f4c-442f-b595-e940779f8e6f", "name": "18d573c6-341a-43af-9f4b-a773e08d4034", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f10a8db9-e4a7-409d-9fe0-0a9c827524fe"}}}]}, {"uuid": "9cd2c69b-6267-4d9c-8085-cee3d6348e34", "name": "load_p1rlv20148_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4a0c2f2-f75e-4c9c-b3f7-d8d9ada9cb82"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "09f7234d-2f4c-442f-b595-e940779f8e6f"}}}}, {"uuid": "662c15fd-8273-4d2a-826c-d63dd0d541a0", "name": "4d2a8b9a-7a08-41c2-9a1f-d7be80a8fc28_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7025097104959883, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.553651846257773, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "13b2ca4a-12c6-4d03-93e8-8035a24731c4", "name": "1accd70c-77fe-4a8b-9f62-a48f71f4108a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "662c15fd-8273-4d2a-826c-d63dd0d541a0"}}}]}, {"uuid": "7dcaeb95-0db1-4839-81dd-b2ffa143a131", "name": "load_p1rlv20148_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4a0c2f2-f75e-4c9c-b3f7-d8d9ada9cb82"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "13b2ca4a-12c6-4d03-93e8-8035a24731c4"}}}}, {"uuid": "3b7d566a-fd60-40c0-888b-37195221ec56", "name": "1eb5f63e-f4c5-47bc-880a-0419ffdc4f60_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.277248598662887, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.143515736159974, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e3821511-30df-465b-acb5-3df5a9431900", "name": "5a7edf86-266b-48de-b000-e3261d2d65ca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3b7d566a-fd60-40c0-888b-37195221ec56"}}}]}, {"uuid": "682c2dbc-2d9f-46b3-a0fc-e78562e8149f", "name": "load_p1rlv20151_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "956f4975-7383-4e0b-9114-d333a6ec4005"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e3821511-30df-465b-acb5-3df5a9431900"}}}}, {"uuid": "6bb11e99-c093-4512-9392-c9dd988042ea", "name": "0acfd7e0-8c71-493f-9322-f74be44fd197_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.277248598662887, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.143515736159974, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3e0146d7-6870-4a6e-a581-9c1c0b4e462b", "name": "5570bc04-89fc-468f-9de1-40cead4ef94f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6bb11e99-c093-4512-9392-c9dd988042ea"}}}]}, {"uuid": "dce30ee9-99e3-4096-a1d2-edfb09ca8731", "name": "load_p1rlv20151_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "956f4975-7383-4e0b-9114-d333a6ec4005"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3e0146d7-6870-4a6e-a581-9c1c0b4e462b"}}}}, {"uuid": "2101c4d2-a7bb-4ec5-a9e0-472a22d2b9ca", "name": "9375f020-eb43-4a91-90bb-7d3471fee0f3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "da803e70-4bd3-4d0f-8a3b-890e59ec93c0", "name": "b8408681-1c10-4ebc-99ce-10c4bb6796e5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2101c4d2-a7bb-4ec5-a9e0-472a22d2b9ca"}}}]}, {"uuid": "e8b7955f-7191-4b62-a82e-079f0f2abdc7", "name": "load_p1rlv20153_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef20846d-d685-4c65-8dfb-bc23317501c5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "da803e70-4bd3-4d0f-8a3b-890e59ec93c0"}}}}, {"uuid": "1322af1c-d5fb-4850-be2e-41cdd0694ee3", "name": "c062e370-2bf3-4980-8f36-b57052d378a5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9353a53d-fd76-4406-82a0-30c0d857bcd0", "name": "f05ecb8f-2027-458d-9583-302b49f3a150", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1322af1c-d5fb-4850-be2e-41cdd0694ee3"}}}]}, {"uuid": "19356f3f-57d5-443b-94c5-61013aa67221", "name": "load_p1rlv20153_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef20846d-d685-4c65-8dfb-bc23317501c5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9353a53d-fd76-4406-82a0-30c0d857bcd0"}}}}, {"uuid": "582666e3-88bd-4406-b4c6-e73bb4b91ba0", "name": "d0e74089-9406-42cb-968c-941ee84e139e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1698158732703443, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8490689598373361, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "53567545-db94-412e-add3-0c889695de31", "name": "8e64aa07-d1a1-4ea2-907b-ace2c89cb4c5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "582666e3-88bd-4406-b4c6-e73bb4b91ba0"}}}]}, {"uuid": "d8613fd8-c758-4c40-98a7-b36993886851", "name": "load_p1rlv20154_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02f2e50e-d42d-47d1-9274-d840042b64d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "53567545-db94-412e-add3-0c889695de31"}}}}, {"uuid": "40f79b36-4145-4613-88ba-89a19ec6e0bf", "name": "f0e82a30-446e-4f1d-9f99-5d6ca2981ced_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1698158732703443, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8490689598373361, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0edebbfd-e6b6-4891-a964-32309e76baf4", "name": "298418b6-5cc5-4ffd-9476-59d005dbfdaa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "40f79b36-4145-4613-88ba-89a19ec6e0bf"}}}]}, {"uuid": "01e845a4-e721-4c3f-8d26-7cb4412b84df", "name": "load_p1rlv20154_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02f2e50e-d42d-47d1-9274-d840042b64d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0edebbfd-e6b6-4891-a964-32309e76baf4"}}}}, {"uuid": "b32c0a9a-d334-4681-857d-fd8ab3a6549d", "name": "cf52475d-8d2b-425a-a6b6-6bd1227771c0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5577393205082823, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5087722503146331, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "01689471-6c73-4ce9-9bac-cb43ee06a20c", "name": "e5d46a68-b1fc-4ec5-86d7-dd92c1328c97", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b32c0a9a-d334-4681-857d-fd8ab3a6549d"}}}]}, {"uuid": "0819d7bb-f90e-43bd-b41a-14b444d08141", "name": "load_p1rlv20160_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27dfea92-734e-49d3-b245-dc933df66889"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "01689471-6c73-4ce9-9bac-cb43ee06a20c"}}}}, {"uuid": "27394fdb-622e-44b6-81d5-1eb9981f00c6", "name": "6e7dcfe2-6b4d-4558-9672-5295b6aa6270_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5577393205082823, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5087722503146331, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "32efff42-1c9a-4a6a-843c-5a318886d726", "name": "4e734bd3-f26b-482b-a8a8-49499875d26a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "27394fdb-622e-44b6-81d5-1eb9981f00c6"}}}]}, {"uuid": "1d5eca10-7bad-482f-80c6-247f8151e31f", "name": "load_p1rlv20160_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27dfea92-734e-49d3-b245-dc933df66889"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "32efff42-1c9a-4a6a-843c-5a318886d726"}}}}, {"uuid": "0755fb9f-6568-4c32-b652-1f92318543fe", "name": "e5463d44-becb-400d-ba47-359a9bf4eed7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.826891988709754, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.5850639012710004, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9906031f-a5da-425e-addb-376808d02468", "name": "b4611dd5-8fd7-4751-bbe7-21bc6d40f9da", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0755fb9f-6568-4c32-b652-1f92318543fe"}}}]}, {"uuid": "f76f88c6-153e-4c33-a478-49634987fdd8", "name": "load_p1rlv20161_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11a125b8-023c-4748-98a9-d74e9e0a7d23"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9906031f-a5da-425e-addb-376808d02468"}}}}, {"uuid": "440780fa-ac19-42bc-b756-9c76d5ee9ca9", "name": "e4e3cfe7-e4c9-4af4-9494-7498213372f2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.826891988709754, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.5850639012710004, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cd182b10-c001-4a5b-9e43-44dc7c455daa", "name": "6753785b-9a38-40d4-ba64-dc7aeda6e217", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "440780fa-ac19-42bc-b756-9c76d5ee9ca9"}}}]}, {"uuid": "befc5031-d584-4387-97d0-6d05dd3b0f94", "name": "load_p1rlv20161_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11a125b8-023c-4748-98a9-d74e9e0a7d23"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cd182b10-c001-4a5b-9e43-44dc7c455daa"}}}}, {"uuid": "2b9916e3-1cc3-40c2-b106-100fbca32bc4", "name": "f482b61d-a170-49f3-adcd-14b9a9aaa2d0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "12c1a588-267c-4df0-92de-712705362eb2", "name": "d546f682-d596-48d1-8a10-beb069f9b663", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2b9916e3-1cc3-40c2-b106-100fbca32bc4"}}}]}, {"uuid": "3186e30a-1daf-47a1-b3a7-7de94b934a1e", "name": "load_p1rlv20163_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e938635b-e0d2-4e1b-a312-5a8f51e1dd7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "12c1a588-267c-4df0-92de-712705362eb2"}}}}, {"uuid": "40513ecc-0631-4feb-bff0-b823f8acbaee", "name": "c21439ba-4ca7-42c0-b8f4-7897a3e295b8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8bb247fa-584b-4826-a3eb-332fb347f14d", "name": "7dbadad6-bb74-4c3f-be9c-5e5f75360e4a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "40513ecc-0631-4feb-bff0-b823f8acbaee"}}}]}, {"uuid": "973dea5e-dd8c-415b-8833-e13c3546485a", "name": "load_p1rlv20163_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e938635b-e0d2-4e1b-a312-5a8f51e1dd7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8bb247fa-584b-4826-a3eb-332fb347f14d"}}}}, {"uuid": "fc046cf8-edf0-4a1f-8754-5be4bb0b4419", "name": "9aa214a9-ac1c-4ac4-be04-d682e3102515_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3462824541838714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7901197550518754, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82ff972c-2cb6-4f7b-bfe3-e8685c86e393", "name": "5a0f9488-66ab-41bf-876b-3a5ad925add7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fc046cf8-edf0-4a1f-8754-5be4bb0b4419"}}}]}, {"uuid": "61c13976-6f8e-4718-8f43-36f89629245a", "name": "load_p1rlv20182_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20f93381-3834-4265-b1ec-5767d171ce0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "82ff972c-2cb6-4f7b-bfe3-e8685c86e393"}}}}, {"uuid": "f5c5ca8e-be6e-4b48-a905-8cd79528f7df", "name": "e7161faf-4531-4d2d-b504-93f71e0fe967_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3462824541838714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7901197550518754, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4eeebcf3-056a-4f59-af07-063d2c3aebeb", "name": "9d0e8107-35e5-4c97-8abe-24118b0ed9d9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f5c5ca8e-be6e-4b48-a905-8cd79528f7df"}}}]}, {"uuid": "812e9359-28ca-4c4c-846e-f1c369d693f9", "name": "load_p1rlv20182_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20f93381-3834-4265-b1ec-5767d171ce0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4eeebcf3-056a-4f59-af07-063d2c3aebeb"}}}}, {"uuid": "a9830c46-efc9-4e6e-9226-0f99af835107", "name": "b61530f2-b813-4330-9c11-d81eedb917b0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8755168938707782, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2009555085079469, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ee98b128-df25-43d4-87c1-f8fe889abcaa", "name": "2142c271-ebf2-4614-8dde-8b98e597f647", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a9830c46-efc9-4e6e-9226-0f99af835107"}}}]}, {"uuid": "88397929-e8cf-468a-ac8a-28e3eb47a3a0", "name": "load_p1rlv20185_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "646058a3-cda7-4723-bd0f-05d305fe7c11"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ee98b128-df25-43d4-87c1-f8fe889abcaa"}}}}, {"uuid": "0d3ad7f6-d3a8-4024-b3c9-bbb592967dab", "name": "0dde55ff-6f5f-4f03-9926-2b0a217728a2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8755168938707782, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2009555085079469, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "277ea683-fcbe-4395-9b33-9052b99b4481", "name": "6177fe72-01fb-4006-b437-863e53d5a251", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0d3ad7f6-d3a8-4024-b3c9-bbb592967dab"}}}]}, {"uuid": "2fe7edb6-18ed-4a59-9a6f-bfb4d2f50581", "name": "load_p1rlv20185_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "646058a3-cda7-4723-bd0f-05d305fe7c11"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "277ea683-fcbe-4395-9b33-9052b99b4481"}}}}, {"uuid": "6e1a9f5a-f7a2-433b-af26-26c9c15d62fe", "name": "8c5d2dcb-b540-4936-9483-c1517b9a0575_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.554325896527151, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5828877012431191, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6d786114-559e-4567-b1a9-491f2ba465f9", "name": "0c229e2e-de38-4ee7-ac97-67c3b5c717cc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6e1a9f5a-f7a2-433b-af26-26c9c15d62fe"}}}]}, {"uuid": "5847e5be-d646-444e-8211-899235c6ef51", "name": "load_p1rlv20188_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abb24254-be79-45d4-8d9b-246b3e89c00f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6d786114-559e-4567-b1a9-491f2ba465f9"}}}}, {"uuid": "3631cd29-11c0-4a70-b9e6-6177be8b554f", "name": "7f4d2eb1-a8d4-4749-ab9e-e92a0cc31f26_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.554325896527151, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5828877012431191, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "115437c8-e691-44ea-9e83-6dc374bc9259", "name": "5b5dfff3-f56a-4af6-b785-50418eaaec42", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3631cd29-11c0-4a70-b9e6-6177be8b554f"}}}]}, {"uuid": "3f45176f-1df3-4292-bc58-2721e0dee7ef", "name": "load_p1rlv20188_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abb24254-be79-45d4-8d9b-246b3e89c00f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "115437c8-e691-44ea-9e83-6dc374bc9259"}}}}, {"uuid": "49562469-1301-4363-95cd-3046593c0adb", "name": "fcd3d06a-e2dc-452a-b50c-2fbaf06ff7b6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0363799452523006, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8773696756055507, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "da655a3b-6207-4105-b2b5-d69624f20812", "name": "6b8dbe70-8270-40b3-a00b-ecd9df03bb39", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "49562469-1301-4363-95cd-3046593c0adb"}}}]}, {"uuid": "7cf357d4-27c1-4541-8cd7-0855ad1b1dc5", "name": "load_p1rlv20277_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb7a8747-a076-469c-a150-35f6763157ec"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "da655a3b-6207-4105-b2b5-d69624f20812"}}}}, {"uuid": "48452f3a-9d18-4066-8409-178fb47c9120", "name": "369c1a0f-a6e3-4469-a1b5-0acd2f52c8e1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0363799452523006, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8773696756055507, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2f45548d-b2ca-4afd-a1d4-558c5eddf0ff", "name": "73e856f3-f8ba-4274-bcc0-4db94de2ad3f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "48452f3a-9d18-4066-8409-178fb47c9120"}}}]}, {"uuid": "a6be9839-5c1b-4d4f-b05c-c986bb22e30b", "name": "load_p1rlv20277_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb7a8747-a076-469c-a150-35f6763157ec"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2f45548d-b2ca-4afd-a1d4-558c5eddf0ff"}}}}, {"uuid": "d41bcd97-b083-4899-8741-6defb5b6dbb0", "name": "23084baa-fb64-4ed3-a74b-f025044ac26b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1813646779377422, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20173832232537287, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9d614edf-f3c2-4712-99e3-094059223132", "name": "e5308187-bb32-4cfb-8b2b-1f60d283de51", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d41bcd97-b083-4899-8741-6defb5b6dbb0"}}}]}, {"uuid": "a1a5093b-f3d8-4fd9-b381-116dec74cf27", "name": "load_p1rlv20281_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f23405b-432f-45ff-a7b1-0b7147cddfc8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9d614edf-f3c2-4712-99e3-094059223132"}}}}, {"uuid": "71c2e802-a315-4089-9729-f73dd906daee", "name": "b4f5e80a-6212-47ed-9404-91a51057ecd2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1813646779377422, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20173832232537287, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b9ba64f9-1cbc-4a5d-be48-20111b1287ef", "name": "8acbf98f-0273-431c-abf0-20ea79a0bc28", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "71c2e802-a315-4089-9729-f73dd906daee"}}}]}, {"uuid": "1755aad6-21f9-4bb5-b0d6-a7ae5e6b3ad5", "name": "load_p1rlv20281_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f23405b-432f-45ff-a7b1-0b7147cddfc8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b9ba64f9-1cbc-4a5d-be48-20111b1287ef"}}}}, {"uuid": "689f32c9-d186-48b3-a8ec-429949952c0f", "name": "01463a59-3f92-4fbd-baed-8cf8b363221e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2766983969851713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5028612878254624, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3f980f97-c5a3-4719-8006-0b9d4aa8b5a3", "name": "3ba769f6-84c3-4d18-b2a7-f90181ad0bc0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "689f32c9-d186-48b3-a8ec-429949952c0f"}}}]}, {"uuid": "e1d8f0c8-3c29-4b77-acc9-9b57270a4d1a", "name": "load_p1rlv20284_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25837ab0-0fb8-4346-94ad-561ff9ff7f0c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3f980f97-c5a3-4719-8006-0b9d4aa8b5a3"}}}}, {"uuid": "97a52d88-a34a-4ad5-b103-602e9e4264e9", "name": "0200df23-bb54-4357-b643-2d48e26695e3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2766983969851713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5028612878254624, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7902ab99-1ca8-45de-a413-dd2372e8f08c", "name": "42525e2f-3479-401f-b10c-276c5855ea32", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "97a52d88-a34a-4ad5-b103-602e9e4264e9"}}}]}, {"uuid": "5c7ebc0b-5d52-45c2-9464-3daa5289b5de", "name": "load_p1rlv20284_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25837ab0-0fb8-4346-94ad-561ff9ff7f0c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7902ab99-1ca8-45de-a413-dd2372e8f08c"}}}}, {"uuid": "d3ea8fe8-e245-4310-bdcd-c00b9ae6a0a0", "name": "d3bf749d-369b-4f9a-a81f-d7cdd696a223_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.883515343353138, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18989418857380705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c49e716e-4a88-4679-aae4-91b2e7bfd7af", "name": "a8a5d2be-83a1-4e95-8713-add634e266c8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d3ea8fe8-e245-4310-bdcd-c00b9ae6a0a0"}}}]}, {"uuid": "73cd87f9-90e9-426c-8cdb-dd9fae4321f5", "name": "load_p1rlv20296_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a8ae6dc-884d-48d8-9995-fe3936ad019c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c49e716e-4a88-4679-aae4-91b2e7bfd7af"}}}}, {"uuid": "e9a77572-7cc3-44e3-aa73-162851150d07", "name": "ed77ba44-c96a-4c66-b55e-6ad9b009db3e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.883515343353138, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18989418857380705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6e3749ca-15f3-4e70-ba98-cb72a5d62b4d", "name": "23aebaf6-1ac9-49fc-8bff-f7387b987557", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e9a77572-7cc3-44e3-aa73-162851150d07"}}}]}, {"uuid": "209538f5-f332-4d02-adf0-a57fe9255933", "name": "load_p1rlv20296_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a8ae6dc-884d-48d8-9995-fe3936ad019c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6e3749ca-15f3-4e70-ba98-cb72a5d62b4d"}}}}, {"uuid": "674e61df-acfa-4ba9-a25c-a0ef9c3d7234", "name": "52a05c32-4595-4e35-8b75-9dfc10adb02f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.882765489125589, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7706550587664386, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3d96ba4a-9748-4117-9115-0ec6e4a84d97", "name": "f149b8f3-ffe6-4eb8-9c70-3037d949c8ce", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "674e61df-acfa-4ba9-a25c-a0ef9c3d7234"}}}]}, {"uuid": "e583e114-43fa-4279-8479-0a9b6f760cd8", "name": "load_p1rlv20300_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da62d78e-e221-423a-8da0-8d36ce1f7508"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3d96ba4a-9748-4117-9115-0ec6e4a84d97"}}}}, {"uuid": "231f7ff9-e2a6-422f-868e-484d14a19fb3", "name": "61ae5d4b-8e33-4476-9faf-c4e177b90cfc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.882765489125589, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7706550587664386, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "814c2e34-5564-4e3c-b825-299f449c1549", "name": "6647d065-688f-4a0c-be0e-57e96810df79", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "231f7ff9-e2a6-422f-868e-484d14a19fb3"}}}]}, {"uuid": "8167385d-15e1-43ed-87a9-157820a44468", "name": "load_p1rlv20300_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da62d78e-e221-423a-8da0-8d36ce1f7508"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "814c2e34-5564-4e3c-b825-299f449c1549"}}}}, {"uuid": "a69441e7-20bf-4633-9680-549d96bc42b5", "name": "e26b65fb-b834-4d3d-abd7-e0398420cb28_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.693241087582845, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5112522017919784, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10eadc14-2c10-4e7e-9c68-5db44d506d7d", "name": "9dacf371-4b31-4a2a-a482-d985e56df868", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a69441e7-20bf-4633-9680-549d96bc42b5"}}}]}, {"uuid": "c60d84a8-585f-4b23-9e8f-683aaaf84f41", "name": "load_p1rlv20309_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e5718ad-0b70-4ea4-b2f2-31f0ea5c5d5b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10eadc14-2c10-4e7e-9c68-5db44d506d7d"}}}}, {"uuid": "3845555f-4b62-4dfc-b4b7-37d8efd82575", "name": "604a9fac-d7a2-44b0-8c14-02e979a21980_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.693241087582845, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5112522017919784, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3061bc64-6954-4cb0-af8c-42bea15eb1ff", "name": "8711a927-6ff3-4819-b6d6-1e02c035eaeb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3845555f-4b62-4dfc-b4b7-37d8efd82575"}}}]}, {"uuid": "d2319eca-b2e2-493f-bbc5-9c465e6d19f1", "name": "load_p1rlv20309_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e5718ad-0b70-4ea4-b2f2-31f0ea5c5d5b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3061bc64-6954-4cb0-af8c-42bea15eb1ff"}}}}, {"uuid": "ab26b536-8e98-4cbd-826e-632038c7aa68", "name": "43a3ddac-87b5-4f7d-a777-e36b7cd087a7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.771789007275423, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6748983225226206, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "94e5a2f6-c580-487f-b991-e648af18c2b3", "name": "789e3f04-ec58-4372-a305-0e7d67f232dd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ab26b536-8e98-4cbd-826e-632038c7aa68"}}}]}, {"uuid": "67d5a93f-9cc6-4996-875a-ead4a2259149", "name": "load_p1rlv20333_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c23afdc0-ab93-4d43-8eec-613eab21cd74"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "94e5a2f6-c580-487f-b991-e648af18c2b3"}}}}, {"uuid": "1f0b1832-82ee-4ba8-8223-466b960951ce", "name": "846779ae-8e22-4d09-81e5-17492a80c258_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.771789007275423, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6748983225226206, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ef8fd0ff-288b-430f-b0cf-cda84570432d", "name": "739f4418-858f-4ed2-9995-c7d33f959819", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1f0b1832-82ee-4ba8-8223-466b960951ce"}}}]}, {"uuid": "63ab5d3b-31a1-40da-b0d8-5e02c8252274", "name": "load_p1rlv20333_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c23afdc0-ab93-4d43-8eec-613eab21cd74"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ef8fd0ff-288b-430f-b0cf-cda84570432d"}}}}, {"uuid": "2c59ab6a-27f7-4bf4-b196-491740e3eea2", "name": "1bf779d5-b9fb-4c49-a1ec-8c5e9c95ad86_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4663769608466568, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5502546109327153, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f0b41a56-9e28-4e39-853a-5fd6b3a3f759", "name": "35f13eff-e9a2-464e-9b8c-a394a22fba9c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2c59ab6a-27f7-4bf4-b196-491740e3eea2"}}}]}, {"uuid": "947a6e02-28d8-48d0-a08b-2755c2ef0a5a", "name": "load_p1rlv20358_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b5d2dfa-895b-4afc-a7fe-449960adba41"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f0b41a56-9e28-4e39-853a-5fd6b3a3f759"}}}}, {"uuid": "f2d0f53c-e96d-4415-9be7-7c18d2921e78", "name": "1d8dc242-b4c0-4991-a303-dd2696fd8062_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4663769608466568, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5502546109327153, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "add10e60-b423-40da-9574-89fe3fd70430", "name": "dab80639-1aba-48f6-82a0-59a1e3a61146", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f2d0f53c-e96d-4415-9be7-7c18d2921e78"}}}]}, {"uuid": "1ff5e68d-e4ac-4cbf-ab60-fa72da086e84", "name": "load_p1rlv20358_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b5d2dfa-895b-4afc-a7fe-449960adba41"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "add10e60-b423-40da-9574-89fe3fd70430"}}}}, {"uuid": "b721e110-586f-4991-b001-e8231b9a661a", "name": "4f4600d5-3b68-43ae-9fc4-682eb9a82ec5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.234980013002153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7303750309107965, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "84307684-e352-4ed0-8167-f34fd87e6a0e", "name": "a37056e5-15cf-46ee-a399-2919d04cef17", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b721e110-586f-4991-b001-e8231b9a661a"}}}]}, {"uuid": "24a685f1-f697-42a7-8baf-26bd8d3a777c", "name": "load_p1rlv20432_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4b5327a-85a3-496c-859c-f887a38513cd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "84307684-e352-4ed0-8167-f34fd87e6a0e"}}}}, {"uuid": "cfe04cf1-1d36-49b4-8437-1c3cfb4ad9ac", "name": "fe88a424-87cc-4d87-8469-62f10e845aae_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.234980013002153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7303750309107965, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dad3dd9c-6e71-48c0-bfcf-864ab6075d33", "name": "5b53255a-f320-42bd-b033-28f0ee0d898d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cfe04cf1-1d36-49b4-8437-1c3cfb4ad9ac"}}}]}, {"uuid": "b338d19c-0240-4a2f-a921-41e0f09d9388", "name": "load_p1rlv20432_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4b5327a-85a3-496c-859c-f887a38513cd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dad3dd9c-6e71-48c0-bfcf-864ab6075d33"}}}}, {"uuid": "2f56313c-3d79-46a7-a0ca-9d045bd29bea", "name": "582f7ddf-5577-4b76-a74c-572604dea4bc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.875485744114147, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.294896241985991, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1702993d-c1f9-4973-b193-3a8585e423a0", "name": "c096483d-27aa-424a-ab54-603c3cb0b381", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2f56313c-3d79-46a7-a0ca-9d045bd29bea"}}}]}, {"uuid": "883a1c8e-13a5-43b7-8fcf-15e3d109de8d", "name": "load_p1rlv20450_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "006c2753-37b3-4b59-82a6-8ce95f316e26"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1702993d-c1f9-4973-b193-3a8585e423a0"}}}}, {"uuid": "ce653358-2d5e-4f72-b43b-295514bc1cad", "name": "cc6468ed-786c-4572-82a8-5d6b57b04a3b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.875485744114147, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.294896241985991, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "18b9c629-85b9-42dc-ab5d-6d5c3b3071cc", "name": "82ea8c9f-863a-4388-a0ae-d3d2203bccbc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ce653358-2d5e-4f72-b43b-295514bc1cad"}}}]}, {"uuid": "b534e7d7-118c-4848-95ae-fcc2f4ed6e5f", "name": "load_p1rlv20450_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "006c2753-37b3-4b59-82a6-8ce95f316e26"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "18b9c629-85b9-42dc-ab5d-6d5c3b3071cc"}}}}, {"uuid": "5b9b6951-75e2-4637-a256-d849e3b06acf", "name": "656a36cf-f25b-4120-8099-158fe0f59230_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b8a0bdaa-7756-4107-b440-71e5df460e62", "name": "18d974a3-94a5-4caa-bd9f-2a1e5338cd51", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b9b6951-75e2-4637-a256-d849e3b06acf"}}}]}, {"uuid": "dd86f627-1fdb-4186-8fd2-5a821ad6b167", "name": "load_p1rlv20451_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c37708d8-1e83-4e76-ac7f-0d29ba6b7c4e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b8a0bdaa-7756-4107-b440-71e5df460e62"}}}}, {"uuid": "2c4105ad-2941-4a5e-8da0-084fe4c47413", "name": "358342e3-0ff1-4fbe-bfe9-b931af7cada5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "11e14820-7282-4d71-a652-1df122e93ae3", "name": "ed38027a-bde9-4103-bada-f0cbe9f21e63", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2c4105ad-2941-4a5e-8da0-084fe4c47413"}}}]}, {"uuid": "d0489582-81ad-47e8-ac14-e3d9782482a9", "name": "load_p1rlv20451_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c37708d8-1e83-4e76-ac7f-0d29ba6b7c4e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "11e14820-7282-4d71-a652-1df122e93ae3"}}}}, {"uuid": "04a63073-b106-4c96-af0d-750e7142c296", "name": "3789b483-2c9e-4cdc-850b-1f6a72bcef77_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.250267265771566, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8009319586825154, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f16238df-3368-4a62-8c92-7c5c72897070", "name": "fa0828f4-8786-4eab-b890-f711c0f4100e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "04a63073-b106-4c96-af0d-750e7142c296"}}}]}, {"uuid": "81cb1766-7c52-4734-b2c2-41c66ce8a702", "name": "load_p1rlv20453_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4e21b79-d2be-4a53-be46-32331e61f89c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f16238df-3368-4a62-8c92-7c5c72897070"}}}}, {"uuid": "d5049aa4-9273-407c-94cf-05ca8a440bb5", "name": "9aed6232-19be-49ed-8f87-15b4a5c57259_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.250267265771566, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8009319586825154, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82923a7e-5484-4585-9ca1-a210dbd4353c", "name": "f8f24d31-bdc4-422b-bb31-6ea4a915fff6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d5049aa4-9273-407c-94cf-05ca8a440bb5"}}}]}, {"uuid": "3130ec59-302e-4764-b6ec-7a2c174c82fc", "name": "load_p1rlv20453_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4e21b79-d2be-4a53-be46-32331e61f89c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "82923a7e-5484-4585-9ca1-a210dbd4353c"}}}}, {"uuid": "5fed4409-884d-4852-aaca-6254e421f131", "name": "48f05232-d2cd-4c7f-b426-e33a74da8e37_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8249779386922644, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12555321354723425, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5cf1d9db-65c5-40e1-a2ad-8266c84ccbeb", "name": "45f27dfc-ed96-4912-abc5-76bb39a907a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5fed4409-884d-4852-aaca-6254e421f131"}}}]}, {"uuid": "d759ae69-49ba-4eae-9068-7d6580520328", "name": "load_p1rlv20455_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8934db59-0c39-4838-9f8c-59a563cd9d54"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5cf1d9db-65c5-40e1-a2ad-8266c84ccbeb"}}}}, {"uuid": "229b6a23-244e-4532-9a35-bca51bcf0c42", "name": "59d624f6-8c91-48de-bad6-4f0278258187_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8249779386922644, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12555321354723425, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cef84716-de5d-4d70-ac0d-8789997937fd", "name": "f1b9614f-d493-439e-8adb-16d290302ab6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "229b6a23-244e-4532-9a35-bca51bcf0c42"}}}]}, {"uuid": "dcfeb706-43bf-4843-a816-558d7581b181", "name": "load_p1rlv20455_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8934db59-0c39-4838-9f8c-59a563cd9d54"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cef84716-de5d-4d70-ac0d-8789997937fd"}}}}, {"uuid": "6d1cbd3e-0a5d-405e-b2a1-5a12b82418ab", "name": "7d23ff30-ed71-4481-9b7e-5f6e41217722_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8374792851175116, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3203908676737591, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "84f5cd6e-2311-496e-b43d-4ca722b1bd78", "name": "663baad0-b0d9-45a7-927e-a0e5745d093d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6d1cbd3e-0a5d-405e-b2a1-5a12b82418ab"}}}]}, {"uuid": "15618555-50c1-4539-9f13-79af73f29385", "name": "load_p1rlv20456_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7a43aa6-2be8-4320-8089-57d388633c6b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "84f5cd6e-2311-496e-b43d-4ca722b1bd78"}}}}, {"uuid": "3d0161c8-eb1c-4ee5-9650-143e945be3cf", "name": "0532cf22-4356-42b2-9e53-0041df647378_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8374792851175116, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3203908676737591, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e1f2743d-7186-44c8-8f9a-eaa189699efd", "name": "92bd0fa1-7f76-4bc0-9d50-9025b4331053", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3d0161c8-eb1c-4ee5-9650-143e945be3cf"}}}]}, {"uuid": "287913e4-5259-480f-8263-e9c579b303b3", "name": "load_p1rlv20456_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7a43aa6-2be8-4320-8089-57d388633c6b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e1f2743d-7186-44c8-8f9a-eaa189699efd"}}}}, {"uuid": "34dc3d17-22d5-4269-b173-57f37f258b5d", "name": "a7178ff2-912b-40c4-83e7-d36982eb2cf3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "daccca9a-4139-4678-8213-c2c1a0d5452b", "name": "c42dc409-047a-4727-b120-e73d258a5d04", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "34dc3d17-22d5-4269-b173-57f37f258b5d"}}}]}, {"uuid": "0427d862-2997-45d5-8577-931c32fbd39d", "name": "load_p1rlv20459_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dfcfdbf-0051-4eef-bea6-97446cee21e4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "daccca9a-4139-4678-8213-c2c1a0d5452b"}}}}, {"uuid": "945cb6b6-8779-42d6-9cb7-b12d175781b1", "name": "bdf587e2-5289-4da2-966b-c4c582a9b1eb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ef5f0664-db91-4bdd-8bb9-3db366347fb4", "name": "6b3f9973-e997-4894-b53c-4f7487109a22", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "945cb6b6-8779-42d6-9cb7-b12d175781b1"}}}]}, {"uuid": "4fa9fb29-e1fd-4f0c-9408-5b718718758e", "name": "load_p1rlv20459_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dfcfdbf-0051-4eef-bea6-97446cee21e4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ef5f0664-db91-4bdd-8bb9-3db366347fb4"}}}}, {"uuid": "401ed287-96c4-47ad-bb6b-c09376d9100b", "name": "fbb8c89b-8c5f-4ce4-ac79-225a79a3328c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8140781365796688, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5845737413475921, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "41ccd785-e72f-49fe-8791-f254aa1574ef", "name": "1b19f048-ac7a-4b40-bfe7-bc60a1426077", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "401ed287-96c4-47ad-bb6b-c09376d9100b"}}}]}, {"uuid": "8793d403-b23e-48cc-9bd9-4c73108709e0", "name": "load_p1rlv20465_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4759390d-43ec-45c9-9cca-320020dc1150"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "41ccd785-e72f-49fe-8791-f254aa1574ef"}}}}, {"uuid": "7fe82b55-5c16-40c9-b10e-5bc64c7fc02d", "name": "b5e45d5d-1bf7-4a54-a0d0-98e9e7e76ef7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8140781365796688, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5845737413475921, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f8024279-8d0b-4396-80aa-b0ebebd0bb90", "name": "18145921-4d73-4934-baed-7944f959f685", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7fe82b55-5c16-40c9-b10e-5bc64c7fc02d"}}}]}, {"uuid": "1ccceec8-8328-4dad-825d-786eb05ffcf0", "name": "load_p1rlv20465_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4759390d-43ec-45c9-9cca-320020dc1150"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f8024279-8d0b-4396-80aa-b0ebebd0bb90"}}}}, {"uuid": "ec91887c-9c4e-45fb-9283-1d9509dc8801", "name": "69b9e34b-1f8a-4670-bfba-5681e8c2ea10_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "565c66a1-9d75-4eb6-9103-dd216b5b89de", "name": "0d7f9147-a203-4140-96f3-5d6a51114635", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ec91887c-9c4e-45fb-9283-1d9509dc8801"}}}]}, {"uuid": "0d76342c-2396-4214-a4bf-f456d4521254", "name": "load_p1rlv20467_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58e2b774-ac04-435e-9e03-573b3aa94cfb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "565c66a1-9d75-4eb6-9103-dd216b5b89de"}}}}, {"uuid": "329fcd7f-6421-421b-a1e9-a0c9774a3398", "name": "c992e272-c468-4173-b205-553f230c7f23_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "83d890be-1de3-4c73-b7f3-4533594fb921", "name": "963b00b2-8d48-461e-aa6b-f857cca4ce80", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "329fcd7f-6421-421b-a1e9-a0c9774a3398"}}}]}, {"uuid": "8018e55d-e577-4e29-81d2-c6b758885388", "name": "load_p1rlv20467_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58e2b774-ac04-435e-9e03-573b3aa94cfb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "83d890be-1de3-4c73-b7f3-4533594fb921"}}}}, {"uuid": "7a1018dc-731c-4c84-8596-ccae7cce63bf", "name": "a66deca1-7605-4fe6-af3e-a2b629aaaf29_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9559171691321495, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6431a71d-fb58-4b2b-8728-b2f14b275221", "name": "99a19f84-1a9f-4e1c-8ba7-d9c94a2d0e14", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7a1018dc-731c-4c84-8596-ccae7cce63bf"}}}]}, {"uuid": "3d34d545-10cb-4ec2-844c-f8aa84b45fdb", "name": "load_p1rlv20469_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60fe0a16-aa4d-4fe8-9f39-81bfa13b505f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6431a71d-fb58-4b2b-8728-b2f14b275221"}}}}, {"uuid": "fc3a51b6-688a-4fe9-8c0f-4da7edd2e08e", "name": "ad5093ab-3779-47c2-834b-3b4c0e4ff47c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9559171691321495, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f374207e-cb43-4462-a20a-bc0597568d97", "name": "62de9be0-ce10-4551-ae7a-ecfc395afad7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fc3a51b6-688a-4fe9-8c0f-4da7edd2e08e"}}}]}, {"uuid": "7a2fe99a-ab27-4605-a90e-794c1864d276", "name": "load_p1rlv20469_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60fe0a16-aa4d-4fe8-9f39-81bfa13b505f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f374207e-cb43-4462-a20a-bc0597568d97"}}}}, {"uuid": "9652105b-26c8-43e1-86c9-fa3508510c4b", "name": "695f24d1-bcff-4c46-96de-e6e71d9e5aaf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.772705532239135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.33568286747913667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5091744d-12e4-4e1b-8838-937c50b63054", "name": "8675ddbe-5371-4ce2-a56e-5ec053964822", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9652105b-26c8-43e1-86c9-fa3508510c4b"}}}]}, {"uuid": "9745b2e8-cce1-42d7-bcb4-17d99d414e3e", "name": "load_p1rlv20473_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3eb214b9-827f-4995-a862-907be02b029d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5091744d-12e4-4e1b-8838-937c50b63054"}}}}, {"uuid": "be39e594-4f05-4bee-9b74-0fac136bb8ec", "name": "bc764a14-2cde-40d3-b6d5-84493c3f6efd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.772705532239135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.33568286747913667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d0a874a8-6ba0-4050-a7cc-c432c61f2415", "name": "15c7b000-6321-4bef-bfa7-4977989eaf80", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "be39e594-4f05-4bee-9b74-0fac136bb8ec"}}}]}, {"uuid": "52a31c24-3b82-4447-8912-06dbd691546d", "name": "load_p1rlv20473_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3eb214b9-827f-4995-a862-907be02b029d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d0a874a8-6ba0-4050-a7cc-c432c61f2415"}}}}, {"uuid": "1d21b064-5365-4048-872a-21abd9d21293", "name": "203c3bda-70e3-493b-b693-f5588be13c2f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "735cda5d-5016-48cd-aaa0-463cd519da98", "name": "157da864-e8b2-4903-b5ed-8c0fe72c4782", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1d21b064-5365-4048-872a-21abd9d21293"}}}]}, {"uuid": "80f467e5-7f90-44a6-8356-7cf7914e5f6d", "name": "load_p1rlv20478_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cd0effe0-d186-41a8-8197-24144fbc6218"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "735cda5d-5016-48cd-aaa0-463cd519da98"}}}}, {"uuid": "7709f9bd-c129-48d8-b9a6-eb8ed8f0e5f1", "name": "068ba0fc-60a4-41bf-bd57-90aea5217b06_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5fb3ed72-dd15-40c3-9fe4-84422b9d980e", "name": "dc761561-95d5-4345-a360-e22a514fd231", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7709f9bd-c129-48d8-b9a6-eb8ed8f0e5f1"}}}]}, {"uuid": "6c849935-fc6e-4c1e-9641-f6249caab38e", "name": "load_p1rlv20478_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cd0effe0-d186-41a8-8197-24144fbc6218"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5fb3ed72-dd15-40c3-9fe4-84422b9d980e"}}}}, {"uuid": "fd483ed2-68e3-445f-b375-06f936328d53", "name": "3d0dde73-4edb-4ff9-81ec-866af2313355_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4437884187508536, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6647073432497462, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "564d4ca5-373b-4f67-b677-422237e5ea0c", "name": "81315c28-c714-483b-af7d-e470c300d902", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fd483ed2-68e3-445f-b375-06f936328d53"}}}]}, {"uuid": "eade93de-ff75-4263-ab36-37f6392c70f8", "name": "load_p1rlv20480_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5d0a174-d49d-4c7e-a669-092f6408edf4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "564d4ca5-373b-4f67-b677-422237e5ea0c"}}}}, {"uuid": "1ce17efe-78d1-4851-ac9e-8ade9592e23b", "name": "bcf26ca4-bb62-446c-ba60-137cc3419286_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4437884187508536, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6647073432497462, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5d58b329-940f-499f-99e1-f5e6ebdd66d0", "name": "c2488af4-3aee-404f-9a2b-844cc1c7ef27", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1ce17efe-78d1-4851-ac9e-8ade9592e23b"}}}]}, {"uuid": "d89233ce-3b5c-40c2-8148-39cb020e8556", "name": "load_p1rlv20480_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5d0a174-d49d-4c7e-a669-092f6408edf4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5d58b329-940f-499f-99e1-f5e6ebdd66d0"}}}}, {"uuid": "39cdc73d-09f9-44e8-822c-9c513c93ff9e", "name": "565e2c77-bd5f-48f1-a5b6-232fd14fd774_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.109177669729331, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5486693289215298, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "66863d2d-5d48-44a0-996e-27f9e773740f", "name": "0cd7736a-ed87-4516-b385-4b23997e7ddd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "39cdc73d-09f9-44e8-822c-9c513c93ff9e"}}}]}, {"uuid": "3be81848-c16d-4e15-8043-56eab74dec44", "name": "load_p1rlv20492_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7af262b7-285c-4d06-b7ff-2f2a1971055a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "66863d2d-5d48-44a0-996e-27f9e773740f"}}}}, {"uuid": "3f800f84-d5ef-474a-be18-715755ebc8ca", "name": "cad3c948-664a-4ddd-a2ae-731cf726bb28_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.109177669729331, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5486693289215298, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f657e04d-89e2-439a-b2c5-dcdcbc637963", "name": "3c70cbae-4ecd-4f93-a71d-6ae728057831", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3f800f84-d5ef-474a-be18-715755ebc8ca"}}}]}, {"uuid": "cc77e7e8-e03c-4713-b2fa-215d3f2c2243", "name": "load_p1rlv20492_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7af262b7-285c-4d06-b7ff-2f2a1971055a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f657e04d-89e2-439a-b2c5-dcdcbc637963"}}}}, {"uuid": "39a51d11-5f0c-46c0-b4c7-2af2dd954ebc", "name": "81a41b58-eb9a-4539-a878-7dba2c28b143_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9444657359992037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.058006608995704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "37b07b41-077a-45c0-9324-13d6a7ba74d4", "name": "de4576f0-f6f8-4e80-8ef6-1773aa55e02e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "39a51d11-5f0c-46c0-b4c7-2af2dd954ebc"}}}]}, {"uuid": "2909b0c0-845f-4562-af72-2f9305e7abba", "name": "load_p1rlv20499_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af153ed-ed39-4433-ac12-19dfdb7b6bef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "37b07b41-077a-45c0-9324-13d6a7ba74d4"}}}}, {"uuid": "fb25be19-608e-41ef-9a56-cfd291dce449", "name": "a6005aed-4468-4377-9284-35ef79ff1428_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9444657359992037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.058006608995704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5ad5caa6-9a08-49c6-904c-a1a531c6ef73", "name": "2e525d33-9f5a-4a97-b599-023512e9421b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fb25be19-608e-41ef-9a56-cfd291dce449"}}}]}, {"uuid": "4a126325-c6b8-473a-a8f8-57f06397f106", "name": "load_p1rlv20499_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af153ed-ed39-4433-ac12-19dfdb7b6bef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5ad5caa6-9a08-49c6-904c-a1a531c6ef73"}}}}, {"uuid": "6d3471e3-3363-42fc-9259-5602fc27ed6c", "name": "1b7f7368-03e3-49c2-aca1-32a570bc7c83_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7956093485713416, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7629429667228578, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "373e538b-b9e4-4ca6-a1f2-6f2097d56b4b", "name": "b4accc81-346a-4c78-adb5-a3e46f18d6ca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6d3471e3-3363-42fc-9259-5602fc27ed6c"}}}]}, {"uuid": "46bb7b31-1c51-4577-a18f-e029061f6d23", "name": "load_p1rlv20502_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cacd3e49-55aa-4f05-bd7d-ae8aba0af87f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "373e538b-b9e4-4ca6-a1f2-6f2097d56b4b"}}}}, {"uuid": "8288e370-9098-494a-965c-85088e722ff3", "name": "05b0d269-5681-4ae5-888d-3811295a6736_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7956093485713416, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7629429667228578, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "141d6878-08dd-4335-838c-ad91b1d41622", "name": "a2055bd1-9ce8-4515-a48e-55eec6b1e260", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8288e370-9098-494a-965c-85088e722ff3"}}}]}, {"uuid": "d8f4b17f-af30-4202-a34d-50a18a3b0803", "name": "load_p1rlv20502_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cacd3e49-55aa-4f05-bd7d-ae8aba0af87f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "141d6878-08dd-4335-838c-ad91b1d41622"}}}}, {"uuid": "3359d395-ff77-4ea4-9c0c-99736773de9c", "name": "32c12bb3-5eca-41a1-99de-3f8946788258_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1419f1bb-43f7-42df-90f7-d852fab4f04f", "name": "a1ab948c-b0c8-467b-8e1d-009a593a9d49", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3359d395-ff77-4ea4-9c0c-99736773de9c"}}}]}, {"uuid": "f5b597dd-6be9-4387-86cd-b9353cfb2945", "name": "load_p1rlv20504_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b3e7495-7732-42ce-8d53-a5f1b7383ce4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1419f1bb-43f7-42df-90f7-d852fab4f04f"}}}}, {"uuid": "1b9c8237-cdcc-4788-8dc9-a2e38cae3cfd", "name": "9fc3d9d1-be67-42d0-b13b-fbe934a1f866_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10916cfb-46ea-418a-9fe5-97fc48b4b6ef", "name": "0f24b9ae-8dad-43d2-9345-f895af4434c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1b9c8237-cdcc-4788-8dc9-a2e38cae3cfd"}}}]}, {"uuid": "d4de4534-9b56-46f9-80ab-765f25e29ca7", "name": "load_p1rlv20504_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b3e7495-7732-42ce-8d53-a5f1b7383ce4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10916cfb-46ea-418a-9fe5-97fc48b4b6ef"}}}}, {"uuid": "c9eb1619-3c3d-4f08-8a82-c8c2946520b8", "name": "cbf50237-7e76-43f1-a222-375cca9e6ed2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4699462180170992, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3815978523472859, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9432afde-7c88-4d3e-868e-97f3205456a3", "name": "6d2fbc95-5243-4480-99fe-ceee1232380c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9eb1619-3c3d-4f08-8a82-c8c2946520b8"}}}]}, {"uuid": "b276dd5f-841c-4c7a-aa73-fbd5e223bf2f", "name": "load_p1rlv20509_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fe37b51-0258-4812-9d96-3cc28c4bd55b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9432afde-7c88-4d3e-868e-97f3205456a3"}}}}, {"uuid": "c8c20fa6-a023-4e8d-a933-7d2719c5465a", "name": "42b7aab2-d56b-4355-88df-e601c8f31bdb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4699462180170992, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3815978523472859, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e7ded97f-bbc4-4b6f-ae64-81781795ede1", "name": "c378b47a-4b56-42f7-8cc0-a1aeeffc51c8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c8c20fa6-a023-4e8d-a933-7d2719c5465a"}}}]}, {"uuid": "f4dfab8b-a25e-41f8-a9f4-e82697795162", "name": "load_p1rlv20509_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fe37b51-0258-4812-9d96-3cc28c4bd55b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e7ded97f-bbc4-4b6f-ae64-81781795ede1"}}}}, {"uuid": "9bf4e191-bba9-4688-86c3-11e2a3b1556c", "name": "486fa29e-1442-4521-b654-5df94e5acf1b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.996798907530164, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8717719006522443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "22e04164-803c-48f5-a56d-12cf40f867a1", "name": "d9db1151-69f7-4de1-9369-643383b87847", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9bf4e191-bba9-4688-86c3-11e2a3b1556c"}}}]}, {"uuid": "d09f7d54-3513-4a3b-bf4f-7fda658684de", "name": "load_p1rlv38126_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa4eed95-33b7-4827-8744-52d14149b386"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "22e04164-803c-48f5-a56d-12cf40f867a1"}}}}, {"uuid": "6736f48a-4c11-43b4-891f-9f29b71f0493", "name": "cd2cfbb2-88c7-4456-88bb-e68221dbd5bf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.996798907530164, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8717719006522443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ca6624d5-7866-48be-9078-6446a8a1c9d2", "name": "9a1029dd-92d1-4ec6-b1c5-2b26f4e507e6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6736f48a-4c11-43b4-891f-9f29b71f0493"}}}]}, {"uuid": "948ee14d-09ae-452c-9a1a-fe2b0b24d3d2", "name": "load_p1rlv38126_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa4eed95-33b7-4827-8744-52d14149b386"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ca6624d5-7866-48be-9078-6446a8a1c9d2"}}}}, {"uuid": "5a62a170-8408-4aee-ac89-b87283b59ca9", "name": "492571f6-4b8e-4149-8af4-782cf955b9e6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.771789007275423, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6748983225226206, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2bc2e514-fab8-4c9f-b7b8-411b8efda667", "name": "9501e8c1-8685-4967-a88e-abf0af5efe9d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5a62a170-8408-4aee-ac89-b87283b59ca9"}}}]}, {"uuid": "397cd87a-7d75-4f45-aa6f-52fe2df03ef8", "name": "load_p1rlv38269_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cbb9976-253c-4863-899f-9218c4496688"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2bc2e514-fab8-4c9f-b7b8-411b8efda667"}}}}, {"uuid": "5214f41f-f6cf-482d-a6ea-e38a09940a99", "name": "0a35ab40-62f0-409a-b114-8c09acffbd43_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.771789007275423, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6748983225226206, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5352644d-0db9-4d77-a7a8-6e0a66ca84b7", "name": "c2b502d9-0a08-4b93-9f2c-0c0ce6dd602b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5214f41f-f6cf-482d-a6ea-e38a09940a99"}}}]}, {"uuid": "fa091356-cbf4-4839-924a-1f6693e3ebbf", "name": "load_p1rlv38269_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cbb9976-253c-4863-899f-9218c4496688"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5352644d-0db9-4d77-a7a8-6e0a66ca84b7"}}}}, {"uuid": "64759ea8-ca8d-455d-ad79-a86f6f4c1078", "name": "2f2a96b2-f5cc-4111-9081-3f1c4b1fe5cd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.981510789736824, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31377757670385525, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "22684b35-2628-4241-8a5b-8bb62902e667", "name": "ddc680e4-e90e-4c70-9b8a-9d25ea26c9d4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "64759ea8-ca8d-455d-ad79-a86f6f4c1078"}}}]}, {"uuid": "02800fdd-973c-4ea6-947e-16920dc24b19", "name": "load_p1rlv51_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ccef6af-4bf6-44dc-b292-2bf9503a374a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "22684b35-2628-4241-8a5b-8bb62902e667"}}}}, {"uuid": "d369ec5a-9562-4ae3-9425-61193f466f3d", "name": "7255ae90-e0cc-4211-a37d-c7c594174568_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.981510789736824, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31377757670385525, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b3a1c1ea-ecc3-4918-9a3e-a9f251be8050", "name": "ce92b254-0249-4534-aa24-f59f9a14d49e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d369ec5a-9562-4ae3-9425-61193f466f3d"}}}]}, {"uuid": "b960c0ed-e728-42b5-ac3e-4f16188cf698", "name": "load_p1rlv51_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ccef6af-4bf6-44dc-b292-2bf9503a374a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b3a1c1ea-ecc3-4918-9a3e-a9f251be8050"}}}}, {"uuid": "61de8132-a291-4b6f-b49b-0b80c583fa54", "name": "13eef270-75e1-49cd-8450-61946b6a081a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5300176124233262, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6781680527999017, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d2143736-d7cb-4e9f-afd6-b762c6c77b83", "name": "96862f7e-44cc-4402-84fc-0a409a7fa1cf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "61de8132-a291-4b6f-b49b-0b80c583fa54"}}}]}, {"uuid": "dc46ae74-9f32-4dee-a22d-5d2f43234fac", "name": "load_p1rlv52_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fec0a162-4b0c-4577-b878-8dbc7c9935fc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d2143736-d7cb-4e9f-afd6-b762c6c77b83"}}}}, {"uuid": "51693030-21ed-433c-b940-8ddbee99ba4d", "name": "94e31f3c-0b45-4c7f-bb84-7f07ffa8a8c2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5300176124233262, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6781680527999017, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "851be08c-93cb-4463-b140-7ed120d378ce", "name": "72332b31-1f7b-4287-a60c-aedf13b24f80", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "51693030-21ed-433c-b940-8ddbee99ba4d"}}}]}, {"uuid": "81a65548-4893-4ebc-9d8f-1b53055dd9e2", "name": "load_p1rlv52_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fec0a162-4b0c-4577-b878-8dbc7c9935fc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "851be08c-93cb-4463-b140-7ed120d378ce"}}}}, {"uuid": "6abbf5df-fbd7-4a80-b490-df552d7a8b46", "name": "b47ca072-cfb7-4733-ad27-193f2f0bfe6b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6434260893942235, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2588956175598443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9e94ad99-4c13-4173-a92b-b7a2de0883ad", "name": "bce8dc23-2a13-447a-9cdb-1cd11f8da7d6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6abbf5df-fbd7-4a80-b490-df552d7a8b46"}}}]}, {"uuid": "fef89029-ffd0-4547-be17-2f8e25fd98c1", "name": "load_p1rlv53_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3c62646-6132-41ef-ba14-a06789885cd5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9e94ad99-4c13-4173-a92b-b7a2de0883ad"}}}}, {"uuid": "052c9588-be83-4b6d-b4e1-ce941bdc6797", "name": "6598428b-fe64-4bf0-b56b-cdda485c2999_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6434260893942235, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2588956175598443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7c9ba43e-b36b-4613-b5a1-25f468b059aa", "name": "d65071fc-6b69-4311-919e-214df90c62b4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "052c9588-be83-4b6d-b4e1-ce941bdc6797"}}}]}, {"uuid": "36946610-1dcc-4134-898b-141d86caebe6", "name": "load_p1rlv53_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3c62646-6132-41ef-ba14-a06789885cd5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7c9ba43e-b36b-4613-b5a1-25f468b059aa"}}}}, {"uuid": "cd4813cb-75e1-4fd1-995f-64aef6215ba9", "name": "9791f066-d559-48f2-8046-be65a4f4d83d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0716401691896973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6949594139700135, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "58b06842-060e-44f2-9f15-d2251967f3b2", "name": "c7e96f2d-342a-4a67-b4cc-f82c59ede79a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cd4813cb-75e1-4fd1-995f-64aef6215ba9"}}}]}, {"uuid": "56cd5e9f-8740-49f4-bb1e-5f4d8f19cfd7", "name": "load_p1rlv54_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20010301-32ce-4cc0-ab59-04ef3bcd35d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "58b06842-060e-44f2-9f15-d2251967f3b2"}}}}, {"uuid": "9c30dcb0-c947-4edc-accb-c0a02c230337", "name": "27a47eaa-eb7a-462e-9760-416f68e5ac5f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0716401691896973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6949594139700135, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6ec27cbf-3b73-4702-b082-dd7b3b1f2564", "name": "d40e052a-8972-4156-910d-04ea499fcc4e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9c30dcb0-c947-4edc-accb-c0a02c230337"}}}]}, {"uuid": "b6b82de1-3192-4c3e-9309-5d13723dfe0d", "name": "load_p1rlv54_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20010301-32ce-4cc0-ab59-04ef3bcd35d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6ec27cbf-3b73-4702-b082-dd7b3b1f2564"}}}}, {"uuid": "fa51dbf9-43bf-446a-9e23-9efce2fb5435", "name": "55e2003d-1b32-40de-8240-29a1f5add95d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3786182488338723, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5359363058124609, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "da3ee55b-aa13-409a-b48a-99c1ccbc9b50", "name": "ef778de1-7ba1-488d-b6e6-68ce6932d203", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fa51dbf9-43bf-446a-9e23-9efce2fb5435"}}}]}, {"uuid": "2f30ac26-a181-4f7c-8a9b-67ee9ead036d", "name": "load_p1rlv55_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36bdbc4e-edfa-425a-8e4c-e6123b567555"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "da3ee55b-aa13-409a-b48a-99c1ccbc9b50"}}}}, {"uuid": "312bc123-0043-4a03-a59d-87fdba87803e", "name": "03cfedd2-dd35-417e-97af-1239244ed228_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3786182488338723, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5359363058124609, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "273079c0-858a-4afc-842d-2db5866bcf6a", "name": "5f32ef60-0009-4b89-ab29-c49613ccf917", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "312bc123-0043-4a03-a59d-87fdba87803e"}}}]}, {"uuid": "487a0692-f420-4664-ba69-a3aaef52c74e", "name": "load_p1rlv55_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36bdbc4e-edfa-425a-8e4c-e6123b567555"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "273079c0-858a-4afc-842d-2db5866bcf6a"}}}}, {"uuid": "0b790946-d246-4c1b-b6d6-0067e4edf3e2", "name": "819ed8f1-a309-4e64-b58c-d80fd571d234_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b87f61d9-a337-4489-9654-b435a567edda", "name": "91ecacfa-eeb4-463b-a4b8-65ff42bbf590", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0b790946-d246-4c1b-b6d6-0067e4edf3e2"}}}]}, {"uuid": "a7ceae31-cc7f-49f5-a440-9c93041c8419", "name": "load_p1rlv56_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4694811a-ba43-4c78-b957-5209b1d961e2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b87f61d9-a337-4489-9654-b435a567edda"}}}}, {"uuid": "4997efb3-15ef-42ea-8a37-5a1d0d1aae2a", "name": "08d09627-4dd8-4c74-91ab-32d60227f297_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6f4634be-569c-45ec-a487-1965bfde5f15", "name": "83670ef5-637f-41d3-b84c-b45d9db70a0c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4997efb3-15ef-42ea-8a37-5a1d0d1aae2a"}}}]}, {"uuid": "070e0bec-c5d5-4935-a573-6a66c8208aff", "name": "load_p1rlv56_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4694811a-ba43-4c78-b957-5209b1d961e2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6f4634be-569c-45ec-a487-1965bfde5f15"}}}}, {"uuid": "ffa4dcab-7823-4f11-bf6a-11622e0b391d", "name": "82fe1b29-d541-46e7-b4b4-8e6e83de5da7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.511185229285174, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8722130080127372, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "31ac6afe-5d0b-494a-b26a-64cf8af68dc9", "name": "c4bda4a5-c91e-4fb1-b56f-ceac0da95f0a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ffa4dcab-7823-4f11-bf6a-11622e0b391d"}}}]}, {"uuid": "eca7e6a5-2e72-498f-98d6-4eca7a795e56", "name": "load_p1rlv57_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "925cb3b7-4ced-4a36-913f-e6851ed79b98"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "31ac6afe-5d0b-494a-b26a-64cf8af68dc9"}}}}, {"uuid": "8aa935a4-9605-4cb6-a05a-b8ebe51f985f", "name": "1126d6d6-6c31-495d-a583-9f93adb3930d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.511185229285174, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8722130080127372, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "804e20fc-ab81-4717-9429-66555387373a", "name": "8ee07f7d-15e5-4163-93f6-810e6c316b6f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8aa935a4-9605-4cb6-a05a-b8ebe51f985f"}}}]}, {"uuid": "1f3e6253-b8e5-4ab5-bdfd-46f9af4444d3", "name": "load_p1rlv57_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "925cb3b7-4ced-4a36-913f-e6851ed79b98"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "804e20fc-ab81-4717-9429-66555387373a"}}}}, {"uuid": "7bfa137b-d37c-442b-ae63-6721da62faca", "name": "3192da5c-462e-401a-ad0d-4ba86cbbac55_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "128dcbb1-a554-4a8c-a0ef-3f10fc6ece9a", "name": "6f48bd8b-c745-40a4-849d-120e366ef0a5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7bfa137b-d37c-442b-ae63-6721da62faca"}}}]}, {"uuid": "c6258ea2-4e94-495b-adcc-c27da8522fb8", "name": "load_p1rlv58_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a32ee184-f677-4333-b7ee-7bc30ab41467"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "128dcbb1-a554-4a8c-a0ef-3f10fc6ece9a"}}}}, {"uuid": "fbb74d60-d121-4c49-a358-66d3b15539f3", "name": "9777a21c-8520-4b8f-94ab-3a37c0672550_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b3f31c27-b8c8-496c-a1c1-6f526e6e4732", "name": "c6816637-b73c-498b-9c46-71c14dd403a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fbb74d60-d121-4c49-a358-66d3b15539f3"}}}]}, {"uuid": "96d1444f-c24b-41c0-89f4-083ac4adab31", "name": "load_p1rlv58_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a32ee184-f677-4333-b7ee-7bc30ab41467"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b3f31c27-b8c8-496c-a1c1-6f526e6e4732"}}}}, {"uuid": "e84d0660-066d-48bc-802c-5cbe6cac2b47", "name": "7ad86ff7-eac6-485e-9469-bb1107c41554_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8939358223380807, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6690937458929831, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "55fe9328-dfab-47ae-939b-f73d69f8ee61", "name": "5e2d0fd5-190f-4dca-90ea-7b395e67f368", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e84d0660-066d-48bc-802c-5cbe6cac2b47"}}}]}, {"uuid": "acf318a8-c7db-41ba-a49a-0d3705a9601e", "name": "load_p1rlv59_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b80bdb24-4bbf-4a57-bd5f-6a5ec9d484dd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "55fe9328-dfab-47ae-939b-f73d69f8ee61"}}}}, {"uuid": "07378ae1-451f-4351-85fa-e652d35d8dbd", "name": "3020cb8a-bacd-4e6c-b4dc-9d71e3b2a96f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8939358223380807, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6690937458929831, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4be7d08b-7d54-4074-9279-18ddfbf4b64d", "name": "944dac61-6bb8-4e25-b5b8-0ac042289404", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "07378ae1-451f-4351-85fa-e652d35d8dbd"}}}]}, {"uuid": "8156076c-aeb1-483e-8f62-90c96d0db843", "name": "load_p1rlv59_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b80bdb24-4bbf-4a57-bd5f-6a5ec9d484dd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4be7d08b-7d54-4074-9279-18ddfbf4b64d"}}}}, {"uuid": "9fd2f010-f617-43a1-90da-a2983bd347c4", "name": "899e1c08-546f-46cd-b858-30141d86191d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1603354468169496, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7593773040340845, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7ffe70a7-2162-4583-80f7-e23d5e9296ff", "name": "da86087f-0581-442c-ae58-fb5788a8094e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9fd2f010-f617-43a1-90da-a2983bd347c4"}}}]}, {"uuid": "40f63329-991b-4813-a3d9-3c0a33f74e01", "name": "load_p1rlv60_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7eb0d1e8-f85e-493e-b69b-26437fdb8ad9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7ffe70a7-2162-4583-80f7-e23d5e9296ff"}}}}, {"uuid": "dc057a50-c489-4f71-97d1-ad27dabaf0d4", "name": "feccd281-58a7-44c6-acad-281c415ca87d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1603354468169496, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7593773040340845, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d548187e-8179-4289-8ff0-3f449d1423ab", "name": "ffa07784-97a4-4bb1-aee9-d15a204eab67", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dc057a50-c489-4f71-97d1-ad27dabaf0d4"}}}]}, {"uuid": "59d7a530-4a41-4dca-a713-21c2102fdf1f", "name": "load_p1rlv60_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7eb0d1e8-f85e-493e-b69b-26437fdb8ad9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d548187e-8179-4289-8ff0-3f449d1423ab"}}}}, {"uuid": "ff35e51b-04ff-4f09-b482-99c27f5da1f3", "name": "f3126d12-75df-4d11-aa4a-a9c08cb9733f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9029063430901945, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8881818750925909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "329ffebf-7a8b-4470-ba34-ac91d74aa28b", "name": "2e847882-3c19-42d4-b0b9-2fdb6d848b33", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ff35e51b-04ff-4f09-b482-99c27f5da1f3"}}}]}, {"uuid": "c5b6c803-9bdd-4411-9f38-652d7968ea5a", "name": "load_p1rlv61_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d22bf2f5-74cc-47c7-ae3b-410fba27c113"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "329ffebf-7a8b-4470-ba34-ac91d74aa28b"}}}}, {"uuid": "8ce51ded-7745-44fc-9206-13f7b36d6891", "name": "3a2fdfa3-b04e-43f7-a3f9-18dc7f50dce9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9029063430901945, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8881818750925909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8210ad11-07f5-4373-9f5d-e77c22d9abef", "name": "c1260533-0133-42de-b91c-5b0f83659704", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ce51ded-7745-44fc-9206-13f7b36d6891"}}}]}, {"uuid": "578e25d2-3757-46ed-889a-360cc36ff3a2", "name": "load_p1rlv61_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d22bf2f5-74cc-47c7-ae3b-410fba27c113"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8210ad11-07f5-4373-9f5d-e77c22d9abef"}}}}, {"uuid": "3c87086a-2cd0-4d24-ab10-d38c58d4b720", "name": "76ddcb3d-8614-4e58-8f65-6f687775ca97_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4622944887503224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10483650830237357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5a347ad2-b6db-42a6-afdf-d1a8a92880b2", "name": "596a8497-bd49-420e-be09-72d24a3a98b7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3c87086a-2cd0-4d24-ab10-d38c58d4b720"}}}]}, {"uuid": "66875e4d-eb39-46ea-a39f-ee24343197db", "name": "load_p1rlv62_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "346dad85-3bf8-41a6-97ea-6b3b40a7f22e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5a347ad2-b6db-42a6-afdf-d1a8a92880b2"}}}}, {"uuid": "100071b2-0732-4f24-8a62-8be1cac1ccdf", "name": "6fdbc8d9-0d4c-4c6f-8661-8f6efc71b762_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4622944887503224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10483650830237357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "44334bee-647e-482e-b736-2ee9d2617deb", "name": "5338051a-88f9-4394-9b46-461b8ba3d191", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "100071b2-0732-4f24-8a62-8be1cac1ccdf"}}}]}, {"uuid": "04f417f8-f826-4bd9-b00e-01479da822d7", "name": "load_p1rlv62_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "346dad85-3bf8-41a6-97ea-6b3b40a7f22e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "44334bee-647e-482e-b736-2ee9d2617deb"}}}}, {"uuid": "8599c743-3264-4e27-b07b-8e70f18fc831", "name": "a4e57bc0-47f2-442e-916e-f28a36b42111_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7083181921938193, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5666922324635131, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "898bad6c-4120-423c-a19a-20da7d4feb01", "name": "5af4bc67-65a3-4da2-b651-b3acc3aef15f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8599c743-3264-4e27-b07b-8e70f18fc831"}}}]}, {"uuid": "78f2f1fb-da78-4ba9-9ad8-070d19f70556", "name": "load_p1rlv63_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8300f90c-9a3b-400d-af04-072125dce84f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "898bad6c-4120-423c-a19a-20da7d4feb01"}}}}, {"uuid": "01f9af62-6d2a-496a-bc8c-344e644cdf96", "name": "28c9d240-6539-4301-8c02-f9fdf480e77a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7083181921938193, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5666922324635131, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "86f365c8-5fb9-4b3e-b9de-50644f943c86", "name": "895b62dd-e0d9-407c-8610-7c3f92f4726a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "01f9af62-6d2a-496a-bc8c-344e644cdf96"}}}]}, {"uuid": "27a20244-06ca-45c4-9084-e1fcc1951a4c", "name": "load_p1rlv63_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8300f90c-9a3b-400d-af04-072125dce84f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "86f365c8-5fb9-4b3e-b9de-50644f943c86"}}}}, {"uuid": "b862f914-18e8-4f3f-a2ab-b4004b0a270c", "name": "c970302a-774f-49bf-b5e0-c2b30e2d230f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "07dab6b3-42a2-4c75-b6aa-e203b274546a", "name": "27d68dc6-3c92-412f-8cd5-96a426254f98", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b862f914-18e8-4f3f-a2ab-b4004b0a270c"}}}]}, {"uuid": "0ad073d3-f5f3-49ce-b085-f94653b6a7b8", "name": "load_p1rlv64_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5efd07ee-012a-40a4-97bb-07c1a5ed898c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "07dab6b3-42a2-4c75-b6aa-e203b274546a"}}}}, {"uuid": "3834f18a-3307-46e7-b128-2cb05ee29fdf", "name": "f42af146-ac7b-40bc-9d07-dc48db61df81_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "70b7f579-bc96-4d4f-8e5b-2676ad9989e2", "name": "35679726-0cd8-413c-9bb7-e7e069ee3ab3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3834f18a-3307-46e7-b128-2cb05ee29fdf"}}}]}, {"uuid": "62f41ebe-0ac1-445e-aa1c-f1b1ee6206c2", "name": "load_p1rlv64_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5efd07ee-012a-40a4-97bb-07c1a5ed898c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "70b7f579-bc96-4d4f-8e5b-2676ad9989e2"}}}}, {"uuid": "59222fb2-eed2-4531-886d-4ab391f26fd8", "name": "a4f53f0f-efda-4c30-9c32-c8d0501a6236_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.987999469244499, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42543082019456707, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aef24bb2-0143-4d23-b28f-76869b6f4d9d", "name": "def2e903-ba3c-4a94-a5f9-dc2fa49a6e46", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "59222fb2-eed2-4531-886d-4ab391f26fd8"}}}]}, {"uuid": "9efc84d7-f9d5-4795-8efd-d75517ccc450", "name": "load_p1rlv65_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e00fd9b-92b3-49c4-bcc2-957b9d2c7bad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aef24bb2-0143-4d23-b28f-76869b6f4d9d"}}}}, {"uuid": "ec001aa8-96b4-426f-ae24-a955358fb564", "name": "006c88d4-217f-4d52-b295-77ce7136abec_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.987999469244499, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42543082019456707, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5575b206-a4d9-4886-b943-6f83eb2da744", "name": "71eb4998-e8dc-46bd-983e-8f6ed559d229", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ec001aa8-96b4-426f-ae24-a955358fb564"}}}]}, {"uuid": "53fe26dd-75ad-46a7-ab2a-913f6a4efeb5", "name": "load_p1rlv65_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e00fd9b-92b3-49c4-bcc2-957b9d2c7bad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5575b206-a4d9-4886-b943-6f83eb2da744"}}}}, {"uuid": "afaef95b-19ae-4d4c-9bd7-29a86ae18b21", "name": "206317db-612b-4704-927f-fbf96927fc4e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4760012569901637, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5456626743322578, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "318e8349-3abc-4e20-b2d2-61184ad007af", "name": "12335a28-a671-4308-894b-a566e26d5169", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "afaef95b-19ae-4d4c-9bd7-29a86ae18b21"}}}]}, {"uuid": "601e7dc9-3f13-4d78-9de3-cac4d1420926", "name": "load_p1rlv66_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e90eb8a2-5db0-4861-96ef-a6991a0386eb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "318e8349-3abc-4e20-b2d2-61184ad007af"}}}}, {"uuid": "1ffcaa05-a532-4271-a582-0ef155917abf", "name": "98dda52b-a2a6-48d9-9ab8-0cb3f98c2c57_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4760012569901637, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5456626743322578, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c9ac0b1d-2a67-4235-b228-a001c83548de", "name": "51011efb-57db-45c9-b4c6-a38f0d590ca6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1ffcaa05-a532-4271-a582-0ef155917abf"}}}]}, {"uuid": "ca7d9648-ce04-409b-a2cb-3c41f2fd3466", "name": "load_p1rlv66_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e90eb8a2-5db0-4861-96ef-a6991a0386eb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c9ac0b1d-2a67-4235-b228-a001c83548de"}}}}, {"uuid": "01480de0-d6dc-4f77-b6fd-baec76795330", "name": "910685f4-8a79-4fb1-8e40-76a0dbc16746_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3018265224045242, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4135325648663858, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "48caeb22-cef1-44ce-8b7f-334baa96534a", "name": "deaf7d4c-d47c-456a-84d0-9426b6fa3647", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "01480de0-d6dc-4f77-b6fd-baec76795330"}}}]}, {"uuid": "56967678-ef97-4b84-8234-803c2743fc1d", "name": "load_p1rlv67_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64a67ed2-a563-4378-b6ac-d9a95339e862"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "48caeb22-cef1-44ce-8b7f-334baa96534a"}}}}, {"uuid": "b4172dd9-f9b8-41e5-99d2-3d6915d07d17", "name": "dc492572-240c-40df-9781-57f5e10675f7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3018265224045242, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4135325648663858, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0f4419de-9c75-4f53-8c77-250c21b8d5a6", "name": "22ea51f2-fbaa-46da-bb8e-d4317fbffd90", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b4172dd9-f9b8-41e5-99d2-3d6915d07d17"}}}]}, {"uuid": "fe5c82ba-f77a-4a58-b55b-703dbebd90a2", "name": "load_p1rlv67_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64a67ed2-a563-4378-b6ac-d9a95339e862"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0f4419de-9c75-4f53-8c77-250c21b8d5a6"}}}}, {"uuid": "7ada4d37-f4d3-40ed-9acd-d5faba481be4", "name": "e25d5b2a-2237-4c29-8fe4-17b6a3691be9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0137187800791063, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5284248988065299, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "543d61c1-6beb-4d3f-ad74-6ac05c55b839", "name": "585ee9d5-3a0b-4e15-af3a-7f3d401331c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7ada4d37-f4d3-40ed-9acd-d5faba481be4"}}}]}, {"uuid": "349f2751-aa29-4c04-984e-19e73fec0a3e", "name": "load_p1rlv68_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c22aa2c8-a6fc-4b27-a875-e07e3f50ecac"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "543d61c1-6beb-4d3f-ad74-6ac05c55b839"}}}}, {"uuid": "2b5d429b-3513-498e-95c9-5e9dcf8f77f7", "name": "13fb1350-2b2d-47f8-94b4-f87982450d96_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0137187800791063, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5284248988065299, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eacc52d2-bcce-4dcc-b6fa-08595047ae7b", "name": "246247a2-c496-41cf-88df-973e7f0884ee", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2b5d429b-3513-498e-95c9-5e9dcf8f77f7"}}}]}, {"uuid": "bc8c3905-1e5c-4811-9bfd-9689ad2d7792", "name": "load_p1rlv68_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c22aa2c8-a6fc-4b27-a875-e07e3f50ecac"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eacc52d2-bcce-4dcc-b6fa-08595047ae7b"}}}}, {"uuid": "fdb23bcf-6111-45ce-ba6c-9007569fce0e", "name": "3808ebb1-face-4a6e-ac7a-7c748c7b669e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7457942211533133, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8784341351558463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b97a3dfb-cc9f-4973-ba82-2213198cebe0", "name": "6768ceee-43be-427e-942b-0db671a29204", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fdb23bcf-6111-45ce-ba6c-9007569fce0e"}}}]}, {"uuid": "efaa2824-5c5f-4090-a1d0-e423cd416f50", "name": "load_p1rlv69_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "876ffb0b-f33c-45b2-a085-7b34103ecffc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b97a3dfb-cc9f-4973-ba82-2213198cebe0"}}}}, {"uuid": "4bc44e80-80e4-4ce6-ac5f-0c25e7ec3613", "name": "34f1e2e2-5b8c-4c0c-bff0-c252aa0692cb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7457942211533133, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8784341351558463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7c06383e-92cc-4e56-819a-5e3f04c47953", "name": "851c42dc-9eee-420a-b9f2-c2aaf0f5858d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4bc44e80-80e4-4ce6-ac5f-0c25e7ec3613"}}}]}, {"uuid": "4e205fd5-defb-40c6-9ee3-9503b82895d3", "name": "load_p1rlv69_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "876ffb0b-f33c-45b2-a085-7b34103ecffc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7c06383e-92cc-4e56-819a-5e3f04c47953"}}}}, {"uuid": "9318faf6-43f3-4b64-b795-832075723229", "name": "db559aeb-98cf-423d-a41a-7164ba97f874_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9024769844937937, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4778358547008617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eba25c14-7d83-4638-8dd7-0112ebd2975b", "name": "1b4e6b62-4c77-4826-a67a-a1f3ff117cd5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9318faf6-43f3-4b64-b795-832075723229"}}}]}, {"uuid": "b67279ba-f49e-43db-945d-e40605cabca3", "name": "load_p1rlv70_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e53e7714-06d1-4f85-89c5-f152629e8ab7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eba25c14-7d83-4638-8dd7-0112ebd2975b"}}}}, {"uuid": "051edfd9-73cd-4d9e-b201-66ecec1ba31a", "name": "23733246-02ee-4dbb-81e6-1328a944508e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9024769844937937, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4778358547008617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f696d473-ce5b-47cc-b65b-283c16067c2a", "name": "b6029e0d-b18c-45df-bae2-892a50823b72", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "051edfd9-73cd-4d9e-b201-66ecec1ba31a"}}}]}, {"uuid": "aa5c61af-18a1-453f-a3f4-a01a6ff35a85", "name": "load_p1rlv70_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e53e7714-06d1-4f85-89c5-f152629e8ab7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f696d473-ce5b-47cc-b65b-283c16067c2a"}}}}, {"uuid": "a5d6224c-b3d0-431d-9687-6aee701eed15", "name": "dcae4974-9e3e-475f-a5f0-c032a786fb75_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.67620786252276, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6753067705079763, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e8511645-a7d1-4737-8cc2-82d08e7818e6", "name": "437ee150-f220-427c-b24f-f817c64d804c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a5d6224c-b3d0-431d-9687-6aee701eed15"}}}]}, {"uuid": "753210c9-2537-407d-8134-f6994ae34c0f", "name": "load_p1rlv71_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d7791de-0cf6-4901-8b95-2d67870f09f5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e8511645-a7d1-4737-8cc2-82d08e7818e6"}}}}, {"uuid": "932477c7-093b-4a62-a26c-00c103b7afb4", "name": "c0c3200b-1955-40cd-a5ec-d8b3427fb9e7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.67620786252276, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6753067705079763, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1979701e-0c8f-4afd-82d1-72025b72e5b5", "name": "8fc03c47-5d22-4a89-ab4e-017f7f49625f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "932477c7-093b-4a62-a26c-00c103b7afb4"}}}]}, {"uuid": "f1e0849b-033d-4707-a5da-2f479ad9b242", "name": "load_p1rlv71_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d7791de-0cf6-4901-8b95-2d67870f09f5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1979701e-0c8f-4afd-82d1-72025b72e5b5"}}}}, {"uuid": "171f09a9-7d92-4ebd-bc33-a8ce323d7740", "name": "601db640-ac9c-4700-8e3d-ce9c23046380_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7083181921938193, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5666922324635131, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "64770796-9427-46e0-87b6-dba6df0d845f", "name": "0b8bba1b-3692-4a6b-9087-cacf89b0b8c6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "171f09a9-7d92-4ebd-bc33-a8ce323d7740"}}}]}, {"uuid": "73bd524a-2a7b-4850-9219-476e289e193a", "name": "load_p1rlv72_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc710fc3-ae5f-478e-997b-85467db7c93c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "64770796-9427-46e0-87b6-dba6df0d845f"}}}}, {"uuid": "18482ac3-1e93-4767-965b-b1551c7ec390", "name": "17d289a0-09c1-4ba9-8024-35bf760e95dd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7083181921938193, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5666922324635131, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e2005fa8-788f-49f4-a6fc-2a3fcb0789b1", "name": "30d7102e-5d90-496d-b7b2-5d74ecb4c561", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "18482ac3-1e93-4767-965b-b1551c7ec390"}}}]}, {"uuid": "2f4bbdec-435b-4b1c-b766-2dc3fd9d6b0b", "name": "load_p1rlv72_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc710fc3-ae5f-478e-997b-85467db7c93c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e2005fa8-788f-49f4-a6fc-2a3fcb0789b1"}}}}, {"uuid": "95a44352-4c4c-4538-a12b-b845882ef1b0", "name": "5dfa04b0-3d87-4fcf-89d3-d2d88f53864c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9051339071763382, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34139556761684264, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c1da838c-955a-49f5-96d2-5b319c046b1b", "name": "6cb71f3e-84ab-4eb1-8d64-e94b484e234f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "95a44352-4c4c-4538-a12b-b845882ef1b0"}}}]}, {"uuid": "72d6dc0d-dbd3-4ed7-99c7-a9079120b408", "name": "load_p1rlv73_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4e2991c-1404-44da-bbb5-5a2ebc43bde4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c1da838c-955a-49f5-96d2-5b319c046b1b"}}}}, {"uuid": "09f3f48f-ccec-44e7-945e-17e6b940dae3", "name": "637008f6-2fb8-4ce9-b3c3-4d5fdb03370d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9051339071763382, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34139556761684264, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8dad0dd4-67e1-45e0-8d3f-29b4204c8f7a", "name": "ba48f13c-9b3f-4f92-bf0f-c05e4b1713f8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "09f3f48f-ccec-44e7-945e-17e6b940dae3"}}}]}, {"uuid": "2c9f38cb-dd0e-47c2-8989-5b42a798d63b", "name": "load_p1rlv73_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4e2991c-1404-44da-bbb5-5a2ebc43bde4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8dad0dd4-67e1-45e0-8d3f-29b4204c8f7a"}}}}, {"uuid": "aced7483-5ca3-4fe3-9a80-7ad42326f6b3", "name": "eeff11e3-ccc5-4d5b-8432-d16b4d08dda8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.4509454152189125, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9978822313633423, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1066ce43-8f62-4734-b2f1-0d2d4e925c63", "name": "e1e3028b-662a-4460-aee6-532ec71815f3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aced7483-5ca3-4fe3-9a80-7ad42326f6b3"}}}]}, {"uuid": "79acc9d8-71a7-41c0-a471-9d9f27e2d3fc", "name": "load_p1rlv74_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5861410e-9d6d-423e-b967-2f2af65610b8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1066ce43-8f62-4734-b2f1-0d2d4e925c63"}}}}, {"uuid": "60451775-92b6-4bf4-9f2c-5448fe20d483", "name": "6d5fcafa-ab52-4b90-a0e2-edcb0734040a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.4509454152189125, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9978822313633423, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "343a81e9-b88c-4f56-8722-4252ebf06a78", "name": "07205db1-1d6a-4850-8bd6-bca3b295fa0e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "60451775-92b6-4bf4-9f2c-5448fe20d483"}}}]}, {"uuid": "dad038de-44f9-459a-bb66-d26063065fe2", "name": "load_p1rlv74_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5861410e-9d6d-423e-b967-2f2af65610b8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "343a81e9-b88c-4f56-8722-4252ebf06a78"}}}}, {"uuid": "e6727a08-79b7-4316-b1fb-92835a5f95c5", "name": "2ead64c7-e386-418d-8808-33609a3ceda3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6211116916449642, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3778136238343289, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8e88cc6c-66b8-49cf-a605-634760d875b6", "name": "d71f38b7-e1be-4217-bdd4-9bf759822e90", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e6727a08-79b7-4316-b1fb-92835a5f95c5"}}}]}, {"uuid": "bd3d2042-a713-4793-9d03-bf8942a59c48", "name": "load_p1rlv75_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ef51371-3fa2-400a-a2b4-3afa97ff2419"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8e88cc6c-66b8-49cf-a605-634760d875b6"}}}}, {"uuid": "7b61b33f-2010-4907-8271-5ff87054e074", "name": "1e148a6c-faa9-4a61-950f-6fd0b951acd4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6211116916449642, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3778136238343289, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "008bf0e6-0413-4467-8e83-1c8f960b4d47", "name": "99b717d0-dd73-4623-a3ab-281f3b99990e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b61b33f-2010-4907-8271-5ff87054e074"}}}]}, {"uuid": "cf336d44-81c4-4f45-81a3-dd94dada5711", "name": "load_p1rlv75_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ef51371-3fa2-400a-a2b4-3afa97ff2419"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "008bf0e6-0413-4467-8e83-1c8f960b4d47"}}}}, {"uuid": "401ab11c-c2ca-4af5-83c5-07c0363178e9", "name": "29ee0be8-831d-4de6-9384-3a20b0130b9b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9972586284721718, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5405993695804993, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8aa83d12-59f5-4bd1-9bab-eb86f3b8f9cd", "name": "49ad30de-c56a-46fa-b952-3da284311066", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "401ab11c-c2ca-4af5-83c5-07c0363178e9"}}}]}, {"uuid": "86acebf5-6adf-437e-bb88-4355e0a18752", "name": "load_p1rlv76_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3354497f-6de7-405d-9fca-a9c77463dc27"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8aa83d12-59f5-4bd1-9bab-eb86f3b8f9cd"}}}}, {"uuid": "a2bc55db-41cc-4697-9041-f6afcc88f075", "name": "5192ad56-41bf-4e17-ba69-df91196fded9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9972586284721718, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5405993695804993, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "212c4d7c-ce43-4ee7-99ea-d311eeb73f6b", "name": "46651f50-b9b3-4d1a-ab92-766edd5c0ea7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a2bc55db-41cc-4697-9041-f6afcc88f075"}}}]}, {"uuid": "829a24fa-03e0-4bb7-85bd-18af6a600c59", "name": "load_p1rlv76_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3354497f-6de7-405d-9fca-a9c77463dc27"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "212c4d7c-ce43-4ee7-99ea-d311eeb73f6b"}}}}, {"uuid": "907cd593-47d9-414c-9363-fc74d801bac8", "name": "5670f2ba-5ba8-4ff2-ac56-2b3074e6c8bc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5906266465914705, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5909884959248153, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "242af08d-0057-4a60-ad70-584db34fe2da", "name": "3bffc9ae-98d9-4564-a1d7-a2043f167347", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "907cd593-47d9-414c-9363-fc74d801bac8"}}}]}, {"uuid": "5b1e63c2-8a7f-49e8-81b4-33c812d96e66", "name": "load_p1rlv77_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f88a22a3-7e6c-4fc5-a8f4-a08cdaa3f5d6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "242af08d-0057-4a60-ad70-584db34fe2da"}}}}, {"uuid": "6c51c685-cd8d-428b-961a-6e577b49da69", "name": "c153e376-cd37-4afd-a4f0-44059fb3bd42_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5906266465914705, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5909884959248153, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f034abf0-9bf2-432b-9076-d81d579ab322", "name": "87ae233a-d756-446d-b7c6-f68f6b8809a8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c51c685-cd8d-428b-961a-6e577b49da69"}}}]}, {"uuid": "863be99e-0075-4534-ac07-5c38053fd75f", "name": "load_p1rlv77_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f88a22a3-7e6c-4fc5-a8f4-a08cdaa3f5d6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f034abf0-9bf2-432b-9076-d81d579ab322"}}}}, {"uuid": "e00ae0f3-c833-4c32-bc1b-62e2800b2ae3", "name": "54b10842-69f3-44d3-983a-1e05f6d6847e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.307297155025492, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20108954410245963, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "49074f23-3cec-4e91-8619-29b4df38c43f", "name": "954509de-44bf-4a2f-adb7-3266478e3ce0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e00ae0f3-c833-4c32-bc1b-62e2800b2ae3"}}}]}, {"uuid": "7ccb5eb7-4b8e-4d08-ba79-67b2d36c0e28", "name": "load_p1rlv78_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae76f058-b79a-4c0f-90be-f9cd7a02bcfc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "49074f23-3cec-4e91-8619-29b4df38c43f"}}}}, {"uuid": "513edbe7-9f8a-47e7-b306-d5ee792f8316", "name": "3fd72f79-30f1-4872-b8ce-b5bf993ace92_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.307297155025492, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20108954410245963, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "67d51062-6006-4e4b-870e-daf7b42dd301", "name": "25a078b4-10c4-4992-ab76-c8d1267af0e8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "513edbe7-9f8a-47e7-b306-d5ee792f8316"}}}]}, {"uuid": "01058f72-29ef-4ad0-ac3b-29577e185af8", "name": "load_p1rlv78_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae76f058-b79a-4c0f-90be-f9cd7a02bcfc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "67d51062-6006-4e4b-870e-daf7b42dd301"}}}}, {"uuid": "f6a96aff-44b9-4310-8cec-c6c2b14b33a8", "name": "b7379432-13b6-4763-a2ca-4bbfbad3f8fb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3315344999322854, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13574204648198762, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1d093d27-94a2-420f-9153-e4364aa561fe", "name": "bdb6170b-c44d-4582-8da9-2ce5e6b2894e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f6a96aff-44b9-4310-8cec-c6c2b14b33a8"}}}]}, {"uuid": "c2d61fb1-e7cb-4984-9dd4-61311694f5ff", "name": "load_p1rlv79_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4dd2283-6100-48ce-b4bc-0e37b7b4e409"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1d093d27-94a2-420f-9153-e4364aa561fe"}}}}, {"uuid": "7e58475c-002a-4f30-8c93-c7f602f794bf", "name": "af5fd900-aa6b-47ea-8c41-bcdfb62950b1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3315344999322854, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13574204648198762, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "678e4c04-ef44-4a06-ad06-ecd15fc903b3", "name": "45d74966-1781-49fc-9ee4-83e8c62a0e43", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7e58475c-002a-4f30-8c93-c7f602f794bf"}}}]}, {"uuid": "90b6d2ad-8447-41d3-8410-66bc45c0a8c4", "name": "load_p1rlv79_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4dd2283-6100-48ce-b4bc-0e37b7b4e409"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "678e4c04-ef44-4a06-ad06-ecd15fc903b3"}}}}, {"uuid": "8e73e272-ff08-4f45-ba2f-09fc3e5a8fa5", "name": "8c8ae855-b307-4833-a21c-c40bc511bc49_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.949137985829372, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.575540256876006, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6bea2e1f-72c3-4820-ab6e-e50a770156b9", "name": "289ae79d-4446-4fa2-afb5-8bda2d97054e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8e73e272-ff08-4f45-ba2f-09fc3e5a8fa5"}}}]}, {"uuid": "36240d9c-fa6e-4e7c-8806-54998ae16ba6", "name": "load_p1rlv80_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab7e1b4a-f8ec-4211-b7a0-d7f9057f576a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6bea2e1f-72c3-4820-ab6e-e50a770156b9"}}}}, {"uuid": "56d0a40d-1c01-4253-bd49-17a4ff33393f", "name": "6bde1f81-0fb4-4d6c-bcb2-37ff2712533a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.949137985829372, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.575540256876006, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8c2651f3-50f5-46e6-9e5f-1325b9300ce7", "name": "3a1244f7-b0f9-41df-9551-4a5222d91c23", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "56d0a40d-1c01-4253-bd49-17a4ff33393f"}}}]}, {"uuid": "9f53e5b8-cc13-4f88-8d06-dbf7d9f9250d", "name": "load_p1rlv80_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab7e1b4a-f8ec-4211-b7a0-d7f9057f576a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8c2651f3-50f5-46e6-9e5f-1325b9300ce7"}}}}, {"uuid": "dacbc3fd-e8fc-41e1-979a-f31318a804a7", "name": "1216a7da-abd7-4d65-893a-79470bfa76d5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.94390101914808, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4734308884348923, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "64d85114-19cb-4b9c-87b4-d99dd2964eb7", "name": "3aebcaa7-c27a-4c99-9dd4-d9ff99542bf0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dacbc3fd-e8fc-41e1-979a-f31318a804a7"}}}]}, {"uuid": "9b5ab49d-17fc-4a4b-824e-c2fd0dc8bc23", "name": "load_p1rlv81_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef92e40c-fe3c-4f7f-b844-884e1079e491"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "64d85114-19cb-4b9c-87b4-d99dd2964eb7"}}}}, {"uuid": "da745182-9985-4a61-8f4e-b5de2ad03235", "name": "46efe056-862e-4385-a344-c132c8299364_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.94390101914808, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4734308884348923, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ee387653-80e7-474e-846c-81b5f5b6a6d2", "name": "26c2ebf2-3c81-4891-8188-e08d41dd10a8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "da745182-9985-4a61-8f4e-b5de2ad03235"}}}]}, {"uuid": "f89298d2-b950-41d4-8276-101df4186a6e", "name": "load_p1rlv81_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef92e40c-fe3c-4f7f-b844-884e1079e491"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ee387653-80e7-474e-846c-81b5f5b6a6d2"}}}}, {"uuid": "af5a52a2-3fe9-4359-93fd-d55143549a28", "name": "1d6d2c06-1203-4968-ac98-b4d4ac8dc5b7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8534881847076217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.812795269620709, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "38eab04b-b674-49e4-bc32-07f6e0824eab", "name": "4e16fa12-982b-48ad-a47a-f250918d5af4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "af5a52a2-3fe9-4359-93fd-d55143549a28"}}}]}, {"uuid": "a62a54a5-6697-443b-a32b-361d4df7db89", "name": "load_p1rlv82_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3ddd704-2530-4392-8e9e-06e047b12f41"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "38eab04b-b674-49e4-bc32-07f6e0824eab"}}}}, {"uuid": "58a22351-641e-471f-8761-366370ea2434", "name": "c93e98c4-b94c-4d47-ae80-bd03cfe25cb2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8534881847076217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.812795269620709, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6fc40c4f-722e-4b46-a59a-49a12373a9cb", "name": "97c7b1a9-89fd-4b27-a3af-81893c03fdeb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58a22351-641e-471f-8761-366370ea2434"}}}]}, {"uuid": "8859a756-2afb-4ba2-b94c-856c2e66a892", "name": "load_p1rlv82_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3ddd704-2530-4392-8e9e-06e047b12f41"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6fc40c4f-722e-4b46-a59a-49a12373a9cb"}}}}, {"uuid": "6bd10507-5bba-4bd0-bef6-a72f290a6b67", "name": "6f2028c5-16e7-4328-8e03-13bf0033686e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.67620786252276, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6753067705079763, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b953ab0d-ba0c-4318-a252-6adef9567579", "name": "f4a2ebc7-287c-4c3b-a6f6-f3ce4a3586f1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6bd10507-5bba-4bd0-bef6-a72f290a6b67"}}}]}, {"uuid": "7665a9b0-76d2-400a-96c0-6f0990926a37", "name": "load_p1rlv83_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24c3e8d8-1520-4a05-84af-a70da6140b4d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b953ab0d-ba0c-4318-a252-6adef9567579"}}}}, {"uuid": "f70363eb-715d-40c7-a5fc-d7a56e04daf3", "name": "ef0c837c-6f9d-47a1-b498-882f08d091ce_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.67620786252276, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6753067705079763, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "78a15a68-4494-4c64-a4d8-7922e66e8997", "name": "f00b83e2-3f0d-4136-bbee-68ce5e3fc5c8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f70363eb-715d-40c7-a5fc-d7a56e04daf3"}}}]}, {"uuid": "88b75824-d49f-4113-a8c6-40ab676f6052", "name": "load_p1rlv83_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24c3e8d8-1520-4a05-84af-a70da6140b4d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "78a15a68-4494-4c64-a4d8-7922e66e8997"}}}}, {"uuid": "ad189afa-a8cc-4feb-aac9-4d99560096bb", "name": "e8272f62-d3e6-4e83-875d-129826f5a230_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2851011950034972, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5829386425893015, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "acd82457-1844-4bec-8ac5-5a37bf06e070", "name": "0374fa7b-d2bf-45ee-b82d-3ce35d0efd09", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ad189afa-a8cc-4feb-aac9-4d99560096bb"}}}]}, {"uuid": "051b254a-b970-418d-92f0-2373c3f21681", "name": "load_p1rlv84_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "55e7538f-4bde-4810-a237-ac0cad7ba805"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "acd82457-1844-4bec-8ac5-5a37bf06e070"}}}}, {"uuid": "1b337f5d-481e-47a9-94e2-6c18b30933c2", "name": "54310b84-29a0-4191-990c-fc85dcf39f15_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2851011950034972, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5829386425893015, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fb46c6ba-5700-4c6f-9aca-52a6c4a67e00", "name": "ad3546ac-85e1-4a6a-be55-77848057669d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1b337f5d-481e-47a9-94e2-6c18b30933c2"}}}]}, {"uuid": "11d28132-44eb-4000-b730-9f6b60fb5574", "name": "load_p1rlv84_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "55e7538f-4bde-4810-a237-ac0cad7ba805"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fb46c6ba-5700-4c6f-9aca-52a6c4a67e00"}}}}, {"uuid": "8ea51f72-6007-45f2-934c-ee720a2a2a6d", "name": "e93d34db-209b-410b-99e8-74e2a10f1f24_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.904546554088597, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7711735109904765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ccf23164-9fe3-498a-8339-0cd4afaaac3b", "name": "34eb3b6c-c8a2-40b9-b54c-561072b6b44d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ea51f72-6007-45f2-934c-ee720a2a2a6d"}}}]}, {"uuid": "23d33e7c-c398-44ea-9d3b-24dfc98d40c8", "name": "load_p1rlv85_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcc52dd9-bacb-4e49-a057-d3747f89a7f7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ccf23164-9fe3-498a-8339-0cd4afaaac3b"}}}}, {"uuid": "55918753-a6a5-4ae9-a332-7fe46c0295e7", "name": "d5657e75-94e2-4bd5-9b06-70f7046f60c4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.904546554088597, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7711735109904765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7069ce04-1c39-41c2-be08-6a3ca23bbda5", "name": "a581fb52-0345-443c-8a00-55901ea16962", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "55918753-a6a5-4ae9-a332-7fe46c0295e7"}}}]}, {"uuid": "c4dba301-7f1a-4f27-a876-cf8834058be0", "name": "load_p1rlv85_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcc52dd9-bacb-4e49-a057-d3747f89a7f7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7069ce04-1c39-41c2-be08-6a3ca23bbda5"}}}}, {"uuid": "35c623f4-72bb-454f-917f-134d2d188e73", "name": "b7492d0b-7810-4e67-b9ff-6ba1915425df_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8309189378455104, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6069744647018672, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c1b59f56-d91c-4edc-bdb4-5b6d88df2d73", "name": "17d3e626-6bd6-420f-b575-cfec57187186", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "35c623f4-72bb-454f-917f-134d2d188e73"}}}]}, {"uuid": "78febb96-7b66-4d6e-941a-633a0723f10e", "name": "load_p1rlv86_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "540e0121-fc39-4c2c-9fbc-012c020f5994"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c1b59f56-d91c-4edc-bdb4-5b6d88df2d73"}}}}, {"uuid": "cb5d3869-1d7a-4b61-85bd-8d1a5aa2b9dd", "name": "93bb007f-267b-4671-9657-383b7126fe63_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8309189378455104, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6069744647018672, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e4bbaed5-dcd9-4e1e-868b-1af88726dd4e", "name": "175acd64-2275-44e6-bd26-30a79b5a1ec6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cb5d3869-1d7a-4b61-85bd-8d1a5aa2b9dd"}}}]}, {"uuid": "9b25e5dd-b353-4e2b-bdd0-8b2f40cc299b", "name": "load_p1rlv86_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "540e0121-fc39-4c2c-9fbc-012c020f5994"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e4bbaed5-dcd9-4e1e-868b-1af88726dd4e"}}}}, {"uuid": "f8606531-663e-47cf-8178-789276058169", "name": "6ab123dc-6c35-4df5-8209-24b8745916dd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6155541211188646, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3901757582026717, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7c78dccd-a904-40f6-aae0-535fd349386c", "name": "d096316e-5678-4fdc-96ea-49e7e048da3b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8606531-663e-47cf-8178-789276058169"}}}]}, {"uuid": "20f2b601-a6da-407d-9ddf-87c50e403dec", "name": "load_p1rlv87_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "46ee0e6c-daf7-4412-94a7-5332a6a97656"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7c78dccd-a904-40f6-aae0-535fd349386c"}}}}, {"uuid": "9b3e1397-1275-46d9-9b9a-44746c91dd20", "name": "258bad8c-9602-4318-9c3c-e2a3e4e2e011_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6155541211188646, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3901757582026717, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3b78c1ee-1cbb-4069-aec6-ee865c5810cf", "name": "fc6c0202-3e9d-4df9-840e-d229a3b85917", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9b3e1397-1275-46d9-9b9a-44746c91dd20"}}}]}, {"uuid": "3be5a22a-d467-4a98-a15c-ee8144f64ffa", "name": "load_p1rlv87_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "46ee0e6c-daf7-4412-94a7-5332a6a97656"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3b78c1ee-1cbb-4069-aec6-ee865c5810cf"}}}}, {"uuid": "98718c72-49ed-4f8b-94f4-4486786a2f17", "name": "8d2cd1f7-4c5f-4548-8f39-8c21701f2f80_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3439175585507637, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8866404836608991, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a834a5c7-98fd-4c36-a1a2-117df752ee7d", "name": "66056a6c-7515-44a0-8fe2-220d35df50b5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "98718c72-49ed-4f8b-94f4-4486786a2f17"}}}]}, {"uuid": "31a2910b-97f0-435f-8446-edb59ff49f20", "name": "load_p1rlv88_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "188047cd-3f14-4240-91fe-30113d48152b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a834a5c7-98fd-4c36-a1a2-117df752ee7d"}}}}, {"uuid": "2205e2f6-a33f-480b-871b-dff81b6dfe6f", "name": "74a63789-fa7d-45df-9e5f-00cf98af8d57_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3439175585507637, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8866404836608991, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "811f21d5-64e0-4d1f-aa87-f48fe0c030be", "name": "22c86dd0-3ef8-43a5-a22d-be5e7a8838b3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2205e2f6-a33f-480b-871b-dff81b6dfe6f"}}}]}, {"uuid": "13edc7c2-1815-4ec8-864b-37a1be4f09ed", "name": "load_p1rlv88_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "188047cd-3f14-4240-91fe-30113d48152b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "811f21d5-64e0-4d1f-aa87-f48fe0c030be"}}}}, {"uuid": "58590f5d-13ba-4b38-bd02-39cb9b23f78c", "name": "e9546252-1b58-4899-9c11-7318389954bc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.872515319591797, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7328111219910317, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "84b98861-33f5-4f04-a307-ce744f52b0a2", "name": "324e5a11-5970-42e7-b780-a2a7a153e909", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58590f5d-13ba-4b38-bd02-39cb9b23f78c"}}}]}, {"uuid": "9df16e4f-d791-4919-8ac9-6fa71869a7f6", "name": "load_p1rlv89_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24d75e9a-0249-48ca-ad10-32738bb6a519"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "84b98861-33f5-4f04-a307-ce744f52b0a2"}}}}, {"uuid": "4411040a-b8aa-4292-8c6f-6b01cd8a0937", "name": "0215f688-785c-42bb-9301-214b3f14d55b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.872515319591797, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7328111219910317, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d71ed8bc-50f6-4a34-bd20-821b33cb7331", "name": "d6b371e7-a88d-4ac8-90bc-da731158d936", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4411040a-b8aa-4292-8c6f-6b01cd8a0937"}}}]}, {"uuid": "68f4c66d-4cd7-49d8-bf03-0e936b39cc47", "name": "load_p1rlv89_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24d75e9a-0249-48ca-ad10-32738bb6a519"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d71ed8bc-50f6-4a34-bd20-821b33cb7331"}}}}, {"uuid": "f0818f91-427a-4dac-859a-9db5b784179b", "name": "606a83fe-20ef-45bd-92c5-f5146a296b44_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6767459289154356, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5300288174067083, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4e5f0c53-8b54-448d-a458-e7d628e7e647", "name": "7d1c415d-e8dc-4012-ba79-b478fef95e10", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f0818f91-427a-4dac-859a-9db5b784179b"}}}]}, {"uuid": "2938636d-de76-44c7-8bae-5ca12ea547e5", "name": "load_p1rlv90_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e06b2ac7-926e-4caf-afac-386910d4ea5e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4e5f0c53-8b54-448d-a458-e7d628e7e647"}}}}, {"uuid": "737e66f7-4b97-4feb-9812-0697f1b837ea", "name": "98a76c71-fc18-4ba7-aaae-ffd2f60dbabf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6767459289154356, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5300288174067083, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "383a78a2-9fcc-402b-a8c8-d9401b3d9bc1", "name": "5bdef5f2-0868-4b5e-8d9b-45781ef23db4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "737e66f7-4b97-4feb-9812-0697f1b837ea"}}}]}, {"uuid": "4e1fefc7-4df0-49fd-9047-d74b8256fd10", "name": "load_p1rlv90_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e06b2ac7-926e-4caf-afac-386910d4ea5e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "383a78a2-9fcc-402b-a8c8-d9401b3d9bc1"}}}}, {"uuid": "18090cd0-1050-4ea4-9081-1b5987f13ed5", "name": "859d3065-e984-44a5-80da-e2ac323cea76_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.089287670026504, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22715368737478026, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dd1b2f42-bfb0-4733-be1f-244a6f9aff0f", "name": "904dc742-32db-4a73-a9b3-ec2156ab46bf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "18090cd0-1050-4ea4-9081-1b5987f13ed5"}}}]}, {"uuid": "99780ee0-abf9-4307-b4e4-ed14d98ebf73", "name": "load_p1rlv91_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a1f01bc-d1f1-4d92-b1e2-1f8223624c52"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dd1b2f42-bfb0-4733-be1f-244a6f9aff0f"}}}}, {"uuid": "fb746a89-e5d8-407e-983a-f03e98d40634", "name": "b0033884-40dc-422f-a2ca-e44dfe1edc9f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.089287670026504, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22715368737478026, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "29c942c6-c2bb-4192-9690-6d377bdf7fa1", "name": "43d21665-1ce2-4376-aa4a-c9603e1290cd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fb746a89-e5d8-407e-983a-f03e98d40634"}}}]}, {"uuid": "9f5996d0-70d0-46af-a97f-981b46824f37", "name": "load_p1rlv91_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a1f01bc-d1f1-4d92-b1e2-1f8223624c52"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "29c942c6-c2bb-4192-9690-6d377bdf7fa1"}}}}, {"uuid": "fe1ba8b5-2e95-43ff-a991-580ba9a4d8e8", "name": "6159d973-f677-4323-8366-eed9b570ef52_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.298373512871933, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.08780226018253445, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6ddbae49-7bba-48e9-b129-7c86cceadc16", "name": "4afa950b-0abb-4e3f-8041-4d9ee05e086c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fe1ba8b5-2e95-43ff-a991-580ba9a4d8e8"}}}]}, {"uuid": "6e7fa03a-2160-4bc3-9a4f-cc003402162c", "name": "load_p1rlv92_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db8f484a-94d5-4d20-8ebf-6708b1601a0d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6ddbae49-7bba-48e9-b129-7c86cceadc16"}}}}, {"uuid": "f8b727ed-1984-40fc-9771-1efd1d55309f", "name": "bd82d5a0-503b-4b3c-b694-64730b273252_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.298373512871933, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.08780226018253445, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5bd4562a-8138-450e-a625-2848c9a1501a", "name": "75349981-2801-4269-9d4f-7e93fd11a841", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8b727ed-1984-40fc-9771-1efd1d55309f"}}}]}, {"uuid": "614d03f1-10f5-420d-b6f1-ae9627c6077f", "name": "load_p1rlv92_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db8f484a-94d5-4d20-8ebf-6708b1601a0d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5bd4562a-8138-450e-a625-2848c9a1501a"}}}}, {"uuid": "acc5f822-9896-4ed6-b7f9-961c04a79fcf", "name": "2d5e9b56-2043-4d51-b09f-0eae337cba7c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1206689642843692, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34257205075767067, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a5557f1-421f-4b7b-928f-124c33d795b9", "name": "3c2684f6-00a4-4532-85da-7a965986254c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "acc5f822-9896-4ed6-b7f9-961c04a79fcf"}}}]}, {"uuid": "c54cefdf-63d6-4bcf-bfae-bcfa3a804ce2", "name": "load_p1rlv93_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0060c029-188f-4725-a935-8d0d9cc892f7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a5557f1-421f-4b7b-928f-124c33d795b9"}}}}, {"uuid": "c677df67-d23d-4c53-a4ad-da31ba873674", "name": "f61f8ad5-a993-4e20-be49-6f3094aae04a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1206689642843692, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34257205075767067, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ae9693df-240a-4ac1-ac44-1fa9ec0c4ac9", "name": "e82986f7-3cd6-4361-b8cd-9dcceedd0c16", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c677df67-d23d-4c53-a4ad-da31ba873674"}}}]}, {"uuid": "cba07de9-9ed8-4aaf-915f-356b567f28e9", "name": "load_p1rlv93_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0060c029-188f-4725-a935-8d0d9cc892f7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ae9693df-240a-4ac1-ac44-1fa9ec0c4ac9"}}}}, {"uuid": "f5710e93-0e63-4dda-8322-b339e9baffcc", "name": "a60b88aa-9ce2-438b-acfd-d3a51a091e64_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.365256087534968, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9406994095530364, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d3515b45-b2cd-4e6d-82dc-9d0d1fcf1ff6", "name": "90eba57b-5b28-40a8-8df5-43435c8b0322", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f5710e93-0e63-4dda-8322-b339e9baffcc"}}}]}, {"uuid": "81751aa3-7248-4487-bbb0-b75319417ef3", "name": "load_p1rlv94_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db2d4080-1f43-47a3-9f3a-e25d1e4f5076"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d3515b45-b2cd-4e6d-82dc-9d0d1fcf1ff6"}}}}, {"uuid": "2bcf0af3-f731-4831-b95e-ab9b2c537f24", "name": "4511a972-ce32-4d4c-9040-93b763ddb4f0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.365256087534968, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9406994095530364, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6746918e-c2fb-499a-a5de-c0c2e352830c", "name": "dacd287d-7ee9-4588-a9d7-cc997c4f5b54", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2bcf0af3-f731-4831-b95e-ab9b2c537f24"}}}]}, {"uuid": "3da52a7f-22d5-4c46-9943-4acb1cf2e86d", "name": "load_p1rlv94_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db2d4080-1f43-47a3-9f3a-e25d1e4f5076"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6746918e-c2fb-499a-a5de-c0c2e352830c"}}}}, {"uuid": "9da11bbe-1bb9-4cbe-aaea-cba496a39b01", "name": "7b735d2a-834d-4e2a-bdd2-b01ed3d8ad3d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2874196130666418, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9219654181970236, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "99b4f378-964b-4383-ad8c-0846925d399a", "name": "0c9ff4eb-c022-4e78-8ab2-7bb6a0a5d5b5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9da11bbe-1bb9-4cbe-aaea-cba496a39b01"}}}]}, {"uuid": "7403fe65-1672-4aa6-bd34-9eec32802b07", "name": "load_p1rlv96_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31508077-f731-47cb-94a9-869d7910e406"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "99b4f378-964b-4383-ad8c-0846925d399a"}}}}, {"uuid": "d2b635de-b7b8-4569-9d7e-06f777a219b5", "name": "4a173121-e8c8-4e35-b054-6f8ceb91a0ae_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2874196130666418, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9219654181970236, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e36bcef7-5406-4902-b65c-0dccf635ba6c", "name": "e39255b9-2c3d-4945-acad-e7ab0a898bea", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d2b635de-b7b8-4569-9d7e-06f777a219b5"}}}]}, {"uuid": "07546d73-cdde-49cf-9284-ed9c72056d08", "name": "load_p1rlv96_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31508077-f731-47cb-94a9-869d7910e406"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e36bcef7-5406-4902-b65c-0dccf635ba6c"}}}}, {"uuid": "c16641aa-8d69-474e-83f8-c5385964d545", "name": "04e55605-b003-4b7c-9d1e-ca79dd286853_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.297832728168154, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6109723215697453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c423ba8b-348a-4c26-81c6-ccd5725736f5", "name": "eaeca3f8-e3de-487d-8694-519965bca661", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c16641aa-8d69-474e-83f8-c5385964d545"}}}]}, {"uuid": "ff0f1762-f691-4ce5-ab27-622a05e5025f", "name": "load_p1rlv98_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "82f19d5c-0941-411d-8baa-3ba029471dae"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c423ba8b-348a-4c26-81c6-ccd5725736f5"}}}}, {"uuid": "bf1c9d20-3c94-45dd-b6cd-2ce537df9f0a", "name": "671e29c0-a4f8-4e6f-8a68-960733b787f0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.297832728168154, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6109723215697453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bc14a11d-391f-4b84-8e60-875d7f8679d5", "name": "9fb52573-f6d7-4fcf-925f-e50b3885a9c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bf1c9d20-3c94-45dd-b6cd-2ce537df9f0a"}}}]}, {"uuid": "7905d68d-503b-472c-967a-7778a52f0994", "name": "load_p1rlv98_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "82f19d5c-0941-411d-8baa-3ba029471dae"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bc14a11d-391f-4b84-8e60-875d7f8679d5"}}}}, {"uuid": "7e69ce24-4795-4dbb-b16c-ef9fa0af989d", "name": "6117d5a6-e73f-4b72-89d1-9c9623c39420_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5294251690866196, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6012221542672356, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c78366f5-22c9-4231-a55e-c5b776304b75", "name": "8c7efc8e-047f-4943-afc9-6ddbb1c58202", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7e69ce24-4795-4dbb-b16c-ef9fa0af989d"}}}]}, {"uuid": "e8df70c9-8f8f-4739-abab-34b80d2a23b0", "name": "load_p1rlv99_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc4a448a-c6cb-4714-b8e6-b75bc6bc219c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c78366f5-22c9-4231-a55e-c5b776304b75"}}}}, {"uuid": "c56ce2ea-ddf1-4f61-bb61-b570626f985a", "name": "202db26d-789c-46af-9ccb-e957aec15c92_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5294251690866196, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6012221542672356, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e5fa98dd-17e0-4883-a85e-6066e6729a98", "name": "fdfadd89-1aab-4f45-9ca4-33d1a298628e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c56ce2ea-ddf1-4f61-bb61-b570626f985a"}}}]}, {"uuid": "cd4a408f-1a33-428f-8101-bed597fcb8c3", "name": "load_p1rlv99_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc4a448a-c6cb-4714-b8e6-b75bc6bc219c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e5fa98dd-17e0-4883-a85e-6066e6729a98"}}}}, {"uuid": "184da65b-8dc6-4ca7-8329-4e9be7d55810", "name": "e1145f98-92e2-4c52-a121-c70a893fee4f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.779437116944347, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0510023138100544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "abf9b856-24e3-43b0-993e-941a700e5987", "name": "c4030a1e-6309-4395-954e-04d3068913d1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "184da65b-8dc6-4ca7-8329-4e9be7d55810"}}}]}, {"uuid": "f15e6046-885a-43de-bd29-9aab72b45f9a", "name": "load_p1rlv100_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62a0d673-eaba-4032-9038-8095e2d53999"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "abf9b856-24e3-43b0-993e-941a700e5987"}}}}, {"uuid": "cfd38289-4519-4c78-9e88-aa9280b90980", "name": "75c824d7-7ace-4c79-ad40-933f5f7e2c5e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.779437116944347, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0510023138100544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "04280e76-fa83-4fed-9f67-b16b1e5b6b49", "name": "3a94513d-40ef-46e5-b7ea-92d4868cf199", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cfd38289-4519-4c78-9e88-aa9280b90980"}}}]}, {"uuid": "215191e3-9ef4-4b21-b313-d2806787197c", "name": "load_p1rlv100_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62a0d673-eaba-4032-9038-8095e2d53999"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "04280e76-fa83-4fed-9f67-b16b1e5b6b49"}}}}, {"uuid": "5b4e2d80-8248-4202-a3e8-45a7ae4710f9", "name": "8247a08c-fdb0-411b-8148-73efe847f6ce_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.684904254134122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42635901069761617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "041fd195-9980-4855-8874-8c010832cf81", "name": "0f69f44e-235d-4ce5-9212-23afb844695f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b4e2d80-8248-4202-a3e8-45a7ae4710f9"}}}]}, {"uuid": "3ee2b65f-9dd7-4934-8212-cd6ef1a27825", "name": "load_p1rlv101_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48d1be49-5aca-4e18-8b85-2a1274b3f26d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "041fd195-9980-4855-8874-8c010832cf81"}}}}, {"uuid": "06baf80c-e581-4a2d-8094-32f6084c37d2", "name": "28e8fd55-991f-4d03-a67c-f331858403d8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.684904254134122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42635901069761617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bf9a217b-e25f-4108-8a18-7d0780f3baab", "name": "e6385cf4-58b6-4786-a1b8-c7b9f35d2275", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "06baf80c-e581-4a2d-8094-32f6084c37d2"}}}]}, {"uuid": "9824b145-a3bb-4887-bf47-ca9d0d0e83ed", "name": "load_p1rlv101_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48d1be49-5aca-4e18-8b85-2a1274b3f26d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bf9a217b-e25f-4108-8a18-7d0780f3baab"}}}}, {"uuid": "235cb1eb-79de-4ad0-8c13-d63c4b99b76d", "name": "deb4cd16-3566-4648-9436-d95d86e4dbd4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3841896439528762, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.62886585412856, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8621e40e-4298-42dc-804a-4591b2e0be9c", "name": "4ab2e48e-e6e1-4262-8492-5932347eb446", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "235cb1eb-79de-4ad0-8c13-d63c4b99b76d"}}}]}, {"uuid": "ae29ac6d-f514-4368-abfe-21c408a60c50", "name": "load_p1rlv102_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06a432e3-dd37-4c52-b954-6652bb529c8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8621e40e-4298-42dc-804a-4591b2e0be9c"}}}}, {"uuid": "1d62996a-acb8-4e7a-a168-70dff02adce8", "name": "eeed8d1d-bef3-4c78-a573-cfe779410549_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3841896439528762, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.62886585412856, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ab2839d8-b9ee-435e-bddd-23a2cc6eb79b", "name": "cda44325-54f8-43ee-ba3b-8a801e25efc0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1d62996a-acb8-4e7a-a168-70dff02adce8"}}}]}, {"uuid": "328b551e-2c99-47e8-94d6-1e6d8062cb39", "name": "load_p1rlv102_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06a432e3-dd37-4c52-b954-6652bb529c8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ab2839d8-b9ee-435e-bddd-23a2cc6eb79b"}}}}, {"uuid": "148e865f-b291-44ae-b89a-29810ad5eaa7", "name": "967f2b60-182a-4b89-968b-14af128f040a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2440101223346245, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10648703060010346, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b829b28a-b328-4762-aca6-6fa9fe5838a9", "name": "b40fd67d-119e-4af8-a80c-6f4c065633f9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "148e865f-b291-44ae-b89a-29810ad5eaa7"}}}]}, {"uuid": "fdd5293f-73d1-4c96-8bfc-9c3a25fc0331", "name": "load_p1rlv103_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85afc796-3fe5-4027-b84e-10d502124636"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b829b28a-b328-4762-aca6-6fa9fe5838a9"}}}}, {"uuid": "b0bedc38-f5ec-4329-986f-8320ea45375f", "name": "0640dbbc-4f29-42ba-a44f-a9bafca5c79b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2440101223346245, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10648703060010346, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "368d54dd-4d93-4beb-8956-ab1d59f80508", "name": "b93ea6cb-86f8-4177-be13-5264cefa5c3e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b0bedc38-f5ec-4329-986f-8320ea45375f"}}}]}, {"uuid": "e8f19935-fdb6-422c-a4ea-650290277367", "name": "load_p1rlv103_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85afc796-3fe5-4027-b84e-10d502124636"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "368d54dd-4d93-4beb-8956-ab1d59f80508"}}}}, {"uuid": "aea1ad96-2ffc-46ed-b4b6-62581ccf1126", "name": "2843f780-0c39-4f88-9e82-8a49607d6a80_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.651721747239447, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.750976002130125, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ba45d071-0691-4fb5-a0fa-d9fbb2f0a8f1", "name": "7344c816-a488-4607-869f-eca427b482d9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aea1ad96-2ffc-46ed-b4b6-62581ccf1126"}}}]}, {"uuid": "0f430a54-77f8-46b6-bbc2-0a0f6f19955f", "name": "load_p1rlv104_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c76c5b8f-1994-470c-a024-b97c73b9bb41"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ba45d071-0691-4fb5-a0fa-d9fbb2f0a8f1"}}}}, {"uuid": "79e38f7e-8b83-4854-b01a-4431739ddef2", "name": "eeefaf38-2a4e-4ed2-a228-202d34333004_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.651721747239447, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.750976002130125, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d960e788-92fb-47d2-8fca-56b2768f1a29", "name": "b7563fdf-9304-4cbf-b1bc-ee9f9adad567", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "79e38f7e-8b83-4854-b01a-4431739ddef2"}}}]}, {"uuid": "bd4d9be8-ecf0-4c23-82f2-e58b4760da60", "name": "load_p1rlv104_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c76c5b8f-1994-470c-a024-b97c73b9bb41"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d960e788-92fb-47d2-8fca-56b2768f1a29"}}}}, {"uuid": "2e8536ec-1a2e-4e27-85a8-b467888ca835", "name": "13b2f988-564c-443c-baad-c2eb203cf2aa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c1ec30df-0bdb-4026-9bc4-a04b856b74e9", "name": "140b9b1c-e959-4ce0-bffa-25f4579b2333", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2e8536ec-1a2e-4e27-85a8-b467888ca835"}}}]}, {"uuid": "d8bfa8fc-8fbd-4255-90e5-e27ccaaa2648", "name": "load_p1rlv105_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fe82ede-430d-454d-b9d0-e212d0621ea1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c1ec30df-0bdb-4026-9bc4-a04b856b74e9"}}}}, {"uuid": "f8007fef-a4cb-415b-a99b-a5914e404d70", "name": "7684eece-222c-4a8a-92f3-bc8020f4d912_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3105f80b-d304-4233-a025-1f6c2ecd50d3", "name": "4f238f30-c677-4975-a961-050e8ea1bed9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8007fef-a4cb-415b-a99b-a5914e404d70"}}}]}, {"uuid": "578f8926-bd9e-4b24-a882-5acb77252820", "name": "load_p1rlv105_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fe82ede-430d-454d-b9d0-e212d0621ea1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3105f80b-d304-4233-a025-1f6c2ecd50d3"}}}}, {"uuid": "14fae872-1b77-45ce-add0-e7976b3630fd", "name": "ed854caa-4326-4a77-93b2-0b14fe09ff85_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.30121669259111117, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.11773911124465561, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9b677954-9657-4c65-ba63-087dba6ab1bb", "name": "f6bc12e0-cfc4-4bc2-b323-86d2ea685920", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "14fae872-1b77-45ce-add0-e7976b3630fd"}}}]}, {"uuid": "f6200b6c-6b46-41fb-b3c5-1862a8054e9d", "name": "load_p1rlv107_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "096e92a6-ea34-435e-a059-57d5234e1654"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9b677954-9657-4c65-ba63-087dba6ab1bb"}}}}, {"uuid": "8ae42569-ca98-43cd-a5f8-37969e71c278", "name": "5691c38e-10b3-48f2-bf5a-2fe899952497_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.30121669259111117, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.11773911124465561, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3c6b4294-6bed-4537-9fa8-ee36816240ed", "name": "63298650-1925-432c-800a-ed81441ae492", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ae42569-ca98-43cd-a5f8-37969e71c278"}}}]}, {"uuid": "ffaf6895-8364-48e3-8054-1985456b2eab", "name": "load_p1rlv107_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "096e92a6-ea34-435e-a059-57d5234e1654"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3c6b4294-6bed-4537-9fa8-ee36816240ed"}}}}, {"uuid": "c35b2abf-c50e-4d68-ad3d-9ae50af82d54", "name": "d0ef8001-1275-4a80-a82a-0af9540d10b9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.522559572152904, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23989402539717328, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e88bd1c6-bc36-40cd-b0c1-7c15933cc79f", "name": "e42ef0cb-6e24-4453-a4b7-866902a90c1e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c35b2abf-c50e-4d68-ad3d-9ae50af82d54"}}}]}, {"uuid": "069c0311-57f5-4fb5-9df1-29924928c296", "name": "load_p1rlv108_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "afc70b80-ab76-440c-b05b-149458051675"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e88bd1c6-bc36-40cd-b0c1-7c15933cc79f"}}}}, {"uuid": "71b788fb-ce89-48a2-aceb-69953c603aab", "name": "79c06ebe-683b-49e5-ad12-61270762b53d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.522559572152904, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23989402539717328, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cf8a5e2f-b19e-41a5-8bff-338e32c1e09c", "name": "fa4c6444-08bd-47a2-97ed-04ada0ff6b1e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "71b788fb-ce89-48a2-aceb-69953c603aab"}}}]}, {"uuid": "3fd99e63-6ab6-44a5-b868-531cf263e5f9", "name": "load_p1rlv108_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "afc70b80-ab76-440c-b05b-149458051675"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cf8a5e2f-b19e-41a5-8bff-338e32c1e09c"}}}}, {"uuid": "8f1d6e19-6d64-4f97-855a-c6626c5778af", "name": "b3e647d6-daaa-422c-871a-4016fbbdddf6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5369480608064634, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2969034126636569, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "516685fd-7351-4510-9728-85aacad9a207", "name": "55c7787a-4d3a-4737-a3a5-8165bcc1d472", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8f1d6e19-6d64-4f97-855a-c6626c5778af"}}}]}, {"uuid": "054abb3b-f1d6-4857-817d-e614797894a3", "name": "load_p1rlv109_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c76fc99c-c160-4ed0-85dd-ec3da962bb24"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "516685fd-7351-4510-9728-85aacad9a207"}}}}, {"uuid": "d62c79c8-4ebc-4d85-9274-1a052f286007", "name": "5ba0d181-1f41-4828-9153-763fc26a1566_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5369480608064634, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2969034126636569, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c979a193-0990-4901-a9ce-244a39c8b763", "name": "ae7c6d8c-3bfe-4e99-8b38-53f7bc6eef9e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d62c79c8-4ebc-4d85-9274-1a052f286007"}}}]}, {"uuid": "1650bce1-bb01-4df4-84aa-eea243ec7930", "name": "load_p1rlv109_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c76fc99c-c160-4ed0-85dd-ec3da962bb24"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c979a193-0990-4901-a9ce-244a39c8b763"}}}}, {"uuid": "24517943-5fde-4054-a339-befca697a048", "name": "4a5ecdab-80cf-4c43-aa11-c20c7ec88038_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4292209363155218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1643515800752328, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f171827b-d16c-4336-9893-c9d50b9e59e0", "name": "b14c8827-88b8-436f-9b1f-b3b1d850c4cf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "24517943-5fde-4054-a339-befca697a048"}}}]}, {"uuid": "d765a2ab-2053-435f-8de7-4c64abc39b0e", "name": "load_p1rlv111_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66748ae6-b6ef-4228-bb0f-f9a121f0e1a3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f171827b-d16c-4336-9893-c9d50b9e59e0"}}}}, {"uuid": "5b0e7b80-45b2-493b-8d9c-424d3d62917b", "name": "d450675c-b18c-41b0-a158-ea2f17f93e06_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4292209363155218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1643515800752328, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f5ab6d2-eb37-49ce-b90a-6435b99c77cd", "name": "3502e7b3-7a68-4ce9-8819-f7679319c5e4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b0e7b80-45b2-493b-8d9c-424d3d62917b"}}}]}, {"uuid": "072461f1-614b-4520-9bef-105e7407bd14", "name": "load_p1rlv111_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66748ae6-b6ef-4228-bb0f-f9a121f0e1a3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f5ab6d2-eb37-49ce-b90a-6435b99c77cd"}}}}, {"uuid": "a129d215-5479-4777-9afd-005fee86592b", "name": "35399736-e507-42af-9286-645d637ea53c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.554325896527151, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5828877012431191, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2ea15295-5d76-48a2-ad39-163db0210208", "name": "b60cd738-ea7d-451b-9fd2-10a38368b834", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a129d215-5479-4777-9afd-005fee86592b"}}}]}, {"uuid": "d37897bf-4995-482d-afae-238a3e5a4765", "name": "load_p1rlv112_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25edc94b-a44b-4200-8cde-73941c2818b8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2ea15295-5d76-48a2-ad39-163db0210208"}}}}, {"uuid": "0ad87fe1-fd4e-495a-a783-359e0194239e", "name": "c665dc92-5a1c-489b-947b-d94f6473342b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.554325896527151, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5828877012431191, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5d7aca6c-9fb3-4efd-9124-b1b7c09671cc", "name": "c95acac6-e43d-4abf-96a7-26ee5bd498a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0ad87fe1-fd4e-495a-a783-359e0194239e"}}}]}, {"uuid": "52b08107-3aaf-466d-aaa2-91607658bc6a", "name": "load_p1rlv112_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25edc94b-a44b-4200-8cde-73941c2818b8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5d7aca6c-9fb3-4efd-9124-b1b7c09671cc"}}}}, {"uuid": "f55f35ca-f906-479e-ada5-5b15d640dd78", "name": "0391e0ae-e8b6-4758-af68-2b1e73941310_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0288569450045768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2608148575838028, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5d05da5e-7c57-4473-894a-9cbd25435b09", "name": "ec30e385-acc1-45b8-ad4f-a7e08a1a93d0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f55f35ca-f906-479e-ada5-5b15d640dd78"}}}]}, {"uuid": "e5606f88-9627-4fde-819e-6a380b5a979b", "name": "load_p1rlv113_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2756378a-0c67-47cf-969d-bdb9e55c8a4b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5d05da5e-7c57-4473-894a-9cbd25435b09"}}}}, {"uuid": "35a42fc6-3d27-405c-b689-6461c37d0bf0", "name": "2e8e1a08-4c19-4975-a423-2bf62e7d8243_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0288569450045768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2608148575838028, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "663fbd3f-6296-4deb-8d4b-239d3aedb205", "name": "b241c0d4-30a7-46eb-bbf8-ae3c01cdc319", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "35a42fc6-3d27-405c-b689-6461c37d0bf0"}}}]}, {"uuid": "42b5dc58-5ed3-42bb-a34e-9f6785057db3", "name": "load_p1rlv113_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2756378a-0c67-47cf-969d-bdb9e55c8a4b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "663fbd3f-6296-4deb-8d4b-239d3aedb205"}}}}, {"uuid": "ee0e5033-82a3-4694-bbb8-33ad3d267e04", "name": "a7547c44-ed9f-4704-a038-b3fbd10d21a0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7419011483459746, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17632142927590772, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c8eeb9e6-96c3-4a2b-bc38-71d012f39165", "name": "50f3db76-64cf-4e1b-a57e-c7172cc3fa46", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ee0e5033-82a3-4694-bbb8-33ad3d267e04"}}}]}, {"uuid": "a14b9591-bce8-4a3f-9c90-e1f4b8a6954b", "name": "load_p1rlv114_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7934cd3-dcd6-4b67-8206-8a3636b6f75d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c8eeb9e6-96c3-4a2b-bc38-71d012f39165"}}}}, {"uuid": "9f118354-5ba0-4d57-b544-d315fa665779", "name": "197f306d-8b59-49a8-b384-bec24c9297a5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7419011483459746, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17632142927590772, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "97559216-4f7a-4506-b67e-9278e3f53e4c", "name": "5b8e997f-2eae-4714-9dc7-c452c92d4a90", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9f118354-5ba0-4d57-b544-d315fa665779"}}}]}, {"uuid": "9d62d752-2c7b-4ee0-8f15-1839d9751b31", "name": "load_p1rlv114_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7934cd3-dcd6-4b67-8206-8a3636b6f75d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "97559216-4f7a-4506-b67e-9278e3f53e4c"}}}}, {"uuid": "b6fd0128-bc95-4086-9e43-7c8ccf220076", "name": "5cd4b925-275d-4ca5-b7bd-64fda137a71d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.883515343353138, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18989418857380705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "878e8f33-af62-487e-9af6-6d0c498d84c8", "name": "8e522171-e97f-471d-8866-b02f7a5f77d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b6fd0128-bc95-4086-9e43-7c8ccf220076"}}}]}, {"uuid": "57839523-1c75-459f-a365-3cd8fbb9fde7", "name": "load_p1rlv115_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "919a48e8-b378-4dd5-8e33-a2602fb58bc0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "878e8f33-af62-487e-9af6-6d0c498d84c8"}}}}, {"uuid": "862cf827-2fa0-4e3a-9d53-d3de3cfff5ee", "name": "1b7f0e82-7b47-4d9b-ac23-d5091debc8bf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.883515343353138, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18989418857380705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1ff35b48-6c02-4af4-943b-a9c4140b8678", "name": "9b5134e1-42e0-4eee-a0b1-f27c6d61ab86", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "862cf827-2fa0-4e3a-9d53-d3de3cfff5ee"}}}]}, {"uuid": "a5b6fcd7-3c22-4997-bb4a-90ad17d41503", "name": "load_p1rlv115_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "919a48e8-b378-4dd5-8e33-a2602fb58bc0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1ff35b48-6c02-4af4-943b-a9c4140b8678"}}}}, {"uuid": "23f0b4e3-06ad-46a0-8acb-16543172da24", "name": "19b07006-31d9-4290-bbb7-26a3a12507fd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7362273540893955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24527287728713068, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e1548353-7017-48de-a9e3-439c9a0bba57", "name": "85aa85ca-0027-4da8-b581-95318cc8a814", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "23f0b4e3-06ad-46a0-8acb-16543172da24"}}}]}, {"uuid": "b5abfb5c-782d-4495-9bd1-e78f868ffb9d", "name": "load_p1rlv117_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e6de569-7f61-439e-a402-850c4f071ab3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e1548353-7017-48de-a9e3-439c9a0bba57"}}}}, {"uuid": "53447ca1-e6c3-4a00-9395-443683755039", "name": "a1db1749-39b2-4dc5-9bb5-b31dca0be6c1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7362273540893955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24527287728713068, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2d59efa9-d691-4ccc-b6a5-27c0fc8f2426", "name": "2f4bafcf-2bc3-4dcc-86e1-1a9567cbaf83", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "53447ca1-e6c3-4a00-9395-443683755039"}}}]}, {"uuid": "80f37d62-ee74-4124-a567-ee5a167a8543", "name": "load_p1rlv117_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e6de569-7f61-439e-a402-850c4f071ab3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2d59efa9-d691-4ccc-b6a5-27c0fc8f2426"}}}}, {"uuid": "e2e4aab7-cf99-48e7-8453-2f94b42aff45", "name": "806914aa-76f2-4988-b1d7-30aca0006156_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.074192704000552, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.129078804753558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "59d83935-cfff-4b37-9176-83da5cd721ff", "name": "98dea8e0-46fc-4d34-bf83-c423a96b79c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e2e4aab7-cf99-48e7-8453-2f94b42aff45"}}}]}, {"uuid": "4e09f639-e11f-4eab-89f1-fafcd4d8cb28", "name": "load_p1rlv118_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "247e37b3-d6d0-41d7-a6b3-ee29d415da50"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "59d83935-cfff-4b37-9176-83da5cd721ff"}}}}, {"uuid": "84bb5902-a714-4e27-aa5d-9b93b75ab90a", "name": "d3b07c70-907f-49c6-b00f-8af495f1e472_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.074192704000552, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.129078804753558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e8ec978d-abb5-4c1a-9abc-40e33eaad1f7", "name": "cefc2605-e448-422f-b93b-4c11333bf9fd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "84bb5902-a714-4e27-aa5d-9b93b75ab90a"}}}]}, {"uuid": "72198056-05f5-4903-8c74-c691d4a32759", "name": "load_p1rlv118_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "247e37b3-d6d0-41d7-a6b3-ee29d415da50"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e8ec978d-abb5-4c1a-9abc-40e33eaad1f7"}}}}, {"uuid": "719a89dd-b219-461d-81df-9f94b751432c", "name": "72182001-19d6-49c5-900d-f269aff2bea9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9571923411347831, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7946531538551662, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "59b30b42-f074-4170-92eb-b8bca83fa949", "name": "9bf0adc2-c199-423c-9395-851dadee10ea", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "719a89dd-b219-461d-81df-9f94b751432c"}}}]}, {"uuid": "33eaf0d1-0bf8-44c0-b0e5-452a215c3cb7", "name": "load_p1rlv119_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee33d90b-2f70-4c9d-863d-6486b95280b8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "59b30b42-f074-4170-92eb-b8bca83fa949"}}}}, {"uuid": "a8d19fde-9e9f-4fbf-8126-909580c17469", "name": "4e0c6550-e775-46e3-9879-acb13d1bdc30_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9571923411347831, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7946531538551662, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "583f5ac1-4c54-4883-8660-c250b7e3cb04", "name": "33bc3b30-57e1-46aa-bc52-31df7304976a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a8d19fde-9e9f-4fbf-8126-909580c17469"}}}]}, {"uuid": "cfe435c8-1fe6-4078-bdb4-a7d971412db5", "name": "load_p1rlv119_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee33d90b-2f70-4c9d-863d-6486b95280b8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "583f5ac1-4c54-4883-8660-c250b7e3cb04"}}}}, {"uuid": "27bf5446-2162-4885-b371-253ccb53de9b", "name": "f8adb0fa-f9c1-493e-b521-27f42c67975b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.297832728168154, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6109723215697453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4611dda0-db86-4242-915a-95dba9b96f8d", "name": "b7856dc6-74d1-4807-a9ee-fc7deb551e87", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "27bf5446-2162-4885-b371-253ccb53de9b"}}}]}, {"uuid": "82a70d6b-169a-4b40-8005-32e139b77ad0", "name": "load_p1rlv120_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a02925cd-7c5b-475f-9e91-30d639bb3c33"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4611dda0-db86-4242-915a-95dba9b96f8d"}}}}, {"uuid": "fad7872b-c335-45bc-aa98-e49b2eca9feb", "name": "ab1c6fed-c9bf-41cb-9a4b-bedce3492fb6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.297832728168154, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6109723215697453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b8fd66d8-f1ee-4917-b670-e9270f82689d", "name": "8566d8fa-2057-401d-860c-630f8ef812f8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fad7872b-c335-45bc-aa98-e49b2eca9feb"}}}]}, {"uuid": "7630ba82-773b-4559-9b9c-8880d22169e5", "name": "load_p1rlv120_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a02925cd-7c5b-475f-9e91-30d639bb3c33"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b8fd66d8-f1ee-4917-b670-e9270f82689d"}}}}, {"uuid": "13b895c5-18b1-4554-a332-4f8bdb4cb7e6", "name": "051a4bcc-e931-46ee-9d3c-808bd76a3c3f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.876043044068563, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8047319040687714, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e59e9b91-2be7-427f-8d2a-b439f06209a6", "name": "fada6878-7d42-49a2-807e-377e437143ff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "13b895c5-18b1-4554-a332-4f8bdb4cb7e6"}}}]}, {"uuid": "afb00e2d-1f8c-48e1-8edf-bb710714ed07", "name": "load_p1rlv121_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0dbaab50-3abc-4207-82dc-5fcc5be68aad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e59e9b91-2be7-427f-8d2a-b439f06209a6"}}}}, {"uuid": "a27d63eb-6dcd-40dc-8442-7c8671032d02", "name": "857e4ea9-3b0f-4208-9244-0af42af4a7e3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.876043044068563, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8047319040687714, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2718d551-8cf3-4600-9dc3-b4c3665e8a0e", "name": "33a47752-67d3-4b44-bde6-d9c114f75f21", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a27d63eb-6dcd-40dc-8442-7c8671032d02"}}}]}, {"uuid": "8ce1fecd-0c60-473b-869a-8a5bf9ff6166", "name": "load_p1rlv121_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0dbaab50-3abc-4207-82dc-5fcc5be68aad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2718d551-8cf3-4600-9dc3-b4c3665e8a0e"}}}}, {"uuid": "49b0e4ba-7ca3-4d34-af13-7e25824e6a76", "name": "1b47beed-07a2-45ae-b215-79e50838f478_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2437699409140923, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5571842941855458, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "84efaaec-d9f7-483f-9ab6-fc0a55a52f8c", "name": "7e10c91e-d599-4df1-a1fe-96851d0cf4a5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "49b0e4ba-7ca3-4d34-af13-7e25824e6a76"}}}]}, {"uuid": "e595319f-e5d3-498c-a031-e65dbe57223c", "name": "load_p1rlv122_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b02739e-d082-4c54-8deb-8ccc83ab82ab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "84efaaec-d9f7-483f-9ab6-fc0a55a52f8c"}}}}, {"uuid": "962e79fe-c222-4e40-9c9f-abbc2ce59cb0", "name": "067aa084-2c75-4d15-97aa-78b3e0b0a153_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2437699409140923, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5571842941855458, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7fa14ede-ebce-495f-9e9f-41b61144d1ff", "name": "3ad50f32-b317-4906-82aa-07733944795c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "962e79fe-c222-4e40-9c9f-abbc2ce59cb0"}}}]}, {"uuid": "eeffb200-c11b-446a-a198-cb403bac7beb", "name": "load_p1rlv122_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b02739e-d082-4c54-8deb-8ccc83ab82ab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7fa14ede-ebce-495f-9e9f-41b61144d1ff"}}}}, {"uuid": "8baad36a-cd5c-4c30-adee-29e71781f3fd", "name": "0dfa85db-08dc-409e-970c-c904c5c307bf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9353742885016981, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3630006054680373, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3c97fce8-7ca0-4309-b2eb-511d255f7ca8", "name": "b2bdc887-8e68-4385-a40f-325bfc8eab82", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8baad36a-cd5c-4c30-adee-29e71781f3fd"}}}]}, {"uuid": "f81f35ba-48df-4e21-9762-47dd4726f97d", "name": "load_p1rlv123_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6184fe8d-ae60-426a-8c0c-a3cc56c5b67e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3c97fce8-7ca0-4309-b2eb-511d255f7ca8"}}}}, {"uuid": "78b81e4a-3d2f-426f-b57f-85fbb095427c", "name": "c66c5166-c614-43f0-b2ea-ec48f019e1a1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9353742885016981, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3630006054680373, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4f4521b7-d7f6-4ec4-acff-ed7bc763dae0", "name": "416a179a-0784-4248-a2eb-67f0088efceb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "78b81e4a-3d2f-426f-b57f-85fbb095427c"}}}]}, {"uuid": "7c31539f-f638-4d65-965a-9d3ea5776d58", "name": "load_p1rlv123_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6184fe8d-ae60-426a-8c0c-a3cc56c5b67e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4f4521b7-d7f6-4ec4-acff-ed7bc763dae0"}}}}, {"uuid": "b3b2c077-f49b-4ef2-a732-d105b0c18c23", "name": "564c20b2-c549-4e21-a5d2-8ad1ba2d061a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4794755457968312, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.46197673612457824, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0fd74c8f-5b7d-440d-ab7b-58c8362163a4", "name": "e570946e-a438-4421-bcc5-7d72ca2612b9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b3b2c077-f49b-4ef2-a732-d105b0c18c23"}}}]}, {"uuid": "686de60c-d247-410b-b7f5-5fcfa2b57dd2", "name": "load_p1rlv124_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e5ca78b-6151-4a35-8a04-1bab215f0f10"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0fd74c8f-5b7d-440d-ab7b-58c8362163a4"}}}}, {"uuid": "3fda8210-f058-400a-95f6-942ca84ae691", "name": "1ce44c52-127a-4e74-b8ef-551022d11d8e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4794755457968312, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.46197673612457824, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b1c9a482-b6ba-4487-9ea8-6c9b7b2aa794", "name": "6aee4861-997c-47f7-a71a-8e27165836d7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3fda8210-f058-400a-95f6-942ca84ae691"}}}]}, {"uuid": "ae132a9a-c8c1-4756-9475-eaee18f1b99a", "name": "load_p1rlv124_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e5ca78b-6151-4a35-8a04-1bab215f0f10"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b1c9a482-b6ba-4487-9ea8-6c9b7b2aa794"}}}}, {"uuid": "b612dfd9-e950-4218-9a85-4200a50d317b", "name": "d1a68747-d3aa-44a9-8aa7-2f4992abe586_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "93059b3a-00fa-44b9-9ad6-92cd637f51fe", "name": "53bd28d2-e9a5-4b07-8ae7-1ed70eb98476", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b612dfd9-e950-4218-9a85-4200a50d317b"}}}]}, {"uuid": "b1748623-6759-4b31-93a1-5bf78c59fb76", "name": "load_p1rlv125_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3367cc2-b096-4cfb-ae71-038eb9e06b46"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "93059b3a-00fa-44b9-9ad6-92cd637f51fe"}}}}, {"uuid": "4c023815-5ad6-4f31-95d2-146176a71953", "name": "fcc40596-9760-41d7-94ed-8f6f7cd31098_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4a3e0581-451c-4c23-a56f-cf3fe911cef8", "name": "fe993a5d-8671-43a7-8e67-9d9689673f1d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4c023815-5ad6-4f31-95d2-146176a71953"}}}]}, {"uuid": "37e8cddf-d42e-4ce9-885b-d33d9cfe3388", "name": "load_p1rlv125_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3367cc2-b096-4cfb-ae71-038eb9e06b46"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4a3e0581-451c-4c23-a56f-cf3fe911cef8"}}}}, {"uuid": "8d060410-1b28-4508-841f-1a239a00d098", "name": "bea2eb65-94f6-44d6-a077-5c7ecacd7036_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5229589832640044, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3359880712066463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e4521922-851e-47ab-bd82-4c196fade484", "name": "a34ea912-dd78-4e06-8965-d6a42c1c87db", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8d060410-1b28-4508-841f-1a239a00d098"}}}]}, {"uuid": "4ef7ff68-ddbb-4dc5-8c3a-fd7218a0591c", "name": "load_p1rlv127_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ae7b1fe-08c4-4848-867e-e2426a325a99"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e4521922-851e-47ab-bd82-4c196fade484"}}}}, {"uuid": "9d1fb586-95ba-4e57-889e-356da6c25cb4", "name": "c59cec42-74f7-4e00-b345-b23208a2b15f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5229589832640044, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3359880712066463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fee10c7c-3ab1-48aa-b412-8bd7d2573dce", "name": "9b24d381-d5f0-43e9-bb9c-fa7a959c0857", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9d1fb586-95ba-4e57-889e-356da6c25cb4"}}}]}, {"uuid": "ac210a2b-1851-4e76-816d-e4e7b4899f93", "name": "load_p1rlv127_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ae7b1fe-08c4-4848-867e-e2426a325a99"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fee10c7c-3ab1-48aa-b412-8bd7d2573dce"}}}}, {"uuid": "b2b15cde-b33b-4e37-b2cf-5316406072de", "name": "64283c63-b3dc-4aee-bf3c-cc0f8573e2f1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4040789998842194, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4565305929598704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "79f9cf11-c820-47a1-9b74-f7369ae38b9f", "name": "47ef9dc3-4340-4d69-b3a7-a480ff9a4e5b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b2b15cde-b33b-4e37-b2cf-5316406072de"}}}]}, {"uuid": "cec1091b-7501-4f4e-b710-95c483f07f5d", "name": "load_p1rlv128_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56bc8935-c658-424c-83d8-0d13bf8d292a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "79f9cf11-c820-47a1-9b74-f7369ae38b9f"}}}}, {"uuid": "f8773ad2-a5dd-4a15-9301-b781dc157354", "name": "ca7087ae-5b39-413c-a0fc-bee47dafc86e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4040789998842194, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4565305929598704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "732c4bbf-d4bf-4149-8316-f476c8c78a2d", "name": "06b6bbb7-9c54-4598-b096-9dc27b8102b1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8773ad2-a5dd-4a15-9301-b781dc157354"}}}]}, {"uuid": "f9ac8698-72e1-42bb-90f8-d43a78c28a3d", "name": "load_p1rlv128_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56bc8935-c658-424c-83d8-0d13bf8d292a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "732c4bbf-d4bf-4149-8316-f476c8c78a2d"}}}}, {"uuid": "eedc1026-34be-47de-a2e0-f3e6ea500bf1", "name": "6b5e0677-f402-49ad-b4ac-193d1f15bed2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7537427041030689, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.37349948863112625, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4574fab1-142f-4cb8-a0b1-dac68b4ab565", "name": "3c75864d-6bb4-4f6f-9f9b-72ae7985f0fd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eedc1026-34be-47de-a2e0-f3e6ea500bf1"}}}]}, {"uuid": "d7f4afb4-7503-4c66-8194-4661a71cb399", "name": "load_p1rlv129_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6c42586-4f46-45c6-910f-90fca771cfd2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4574fab1-142f-4cb8-a0b1-dac68b4ab565"}}}}, {"uuid": "24d808e0-a25d-41bc-8aaf-9990eccb7ab4", "name": "56088df8-55c7-4fdc-896a-5f04e6ccb015_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7537427041030689, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.37349948863112625, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f39fe77-3d73-48ab-92ba-9fb9f8622ce2", "name": "f250c745-893d-400e-85f3-dccb3b92119b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "24d808e0-a25d-41bc-8aaf-9990eccb7ab4"}}}]}, {"uuid": "d92713c4-e2f3-475e-80e6-43f4332b0f7c", "name": "load_p1rlv129_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6c42586-4f46-45c6-910f-90fca771cfd2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f39fe77-3d73-48ab-92ba-9fb9f8622ce2"}}}}, {"uuid": "7206e78c-dc01-4a88-87dc-92f12b81c5ed", "name": "85c77c54-09b7-4b11-99df-3d2d2fb35559_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.297832728168154, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6109723215697453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4a29d63e-dea1-442d-a272-760c694e029c", "name": "9222c3b6-9c12-463a-8ec0-a7a065b61a82", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7206e78c-dc01-4a88-87dc-92f12b81c5ed"}}}]}, {"uuid": "c0a5d83c-19a2-4bbe-b430-96cd86c3ec5d", "name": "load_p1rlv130_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5c96953-6710-4765-b5bd-4359e03e4c63"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4a29d63e-dea1-442d-a272-760c694e029c"}}}}, {"uuid": "79588cfd-8b16-4b36-a195-5326be554ce5", "name": "a1928b35-55c4-4a97-bb90-117bc2179089_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.297832728168154, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6109723215697453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "780efec7-3429-400e-826c-6f883f72604d", "name": "36491887-4033-4fee-a6d9-2f3cac618305", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "79588cfd-8b16-4b36-a195-5326be554ce5"}}}]}, {"uuid": "7e42a97a-9ca0-445f-89dc-e988ed19372b", "name": "load_p1rlv130_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5c96953-6710-4765-b5bd-4359e03e4c63"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "780efec7-3429-400e-826c-6f883f72604d"}}}}, {"uuid": "9b2700f3-4011-4344-bdf5-7dc7f7441c55", "name": "3e5929fc-8438-437c-8433-c5f322bc79ba_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3885774782241163, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12624891415512582, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "390771cc-dc65-47c4-8419-4787ae8f5e54", "name": "b665265e-dc12-4058-8a80-9a4aaf2a8bcf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9b2700f3-4011-4344-bdf5-7dc7f7441c55"}}}]}, {"uuid": "5413e231-368b-4a65-8ed8-a723bdf8923d", "name": "load_p1rlv131_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "499fb461-ccb6-436a-8078-eec9beffb4a9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "390771cc-dc65-47c4-8419-4787ae8f5e54"}}}}, {"uuid": "c4778803-e672-41a7-94e1-30a30aa54414", "name": "343e43df-a998-42a9-a472-71fac05ed739_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3885774782241163, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12624891415512582, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1822e842-8251-466f-b5a8-9dfbd1cf9d26", "name": "747b0fbe-bcf2-4d83-b894-a7ebfa1d1448", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c4778803-e672-41a7-94e1-30a30aa54414"}}}]}, {"uuid": "3a3aa4b8-ceae-4213-a03e-7a8dc52d0961", "name": "load_p1rlv131_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "499fb461-ccb6-436a-8078-eec9beffb4a9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1822e842-8251-466f-b5a8-9dfbd1cf9d26"}}}}, {"uuid": "39b9e37a-0501-4cc6-b4a9-74a2fc2b9cf0", "name": "8a32d994-7583-4752-b441-2f6e02dd5b1d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0137187800791063, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5284248988065299, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8e10c4cb-8e1d-4851-8987-ae9eace6d8d0", "name": "f6478ee6-3a57-4bba-94ee-56361b3e3858", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "39b9e37a-0501-4cc6-b4a9-74a2fc2b9cf0"}}}]}, {"uuid": "3f42414d-fc02-43d7-91a3-6ad9eb55c592", "name": "load_p1rlv132_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41960437-e2e6-4746-89c2-81c81602ca1b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8e10c4cb-8e1d-4851-8987-ae9eace6d8d0"}}}}, {"uuid": "69280a7b-28c9-4d85-877f-dd1248b7248b", "name": "1f19a2e4-25a5-407b-8454-2be5b63972a5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0137187800791063, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5284248988065299, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "164140b5-919a-4b39-93e9-6db867cf4762", "name": "7fb42886-cae4-444b-92db-facbd41dab72", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "69280a7b-28c9-4d85-877f-dd1248b7248b"}}}]}, {"uuid": "ae0dee1d-c463-4e8f-ae0a-82810bc1685d", "name": "load_p1rlv132_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41960437-e2e6-4746-89c2-81c81602ca1b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "164140b5-919a-4b39-93e9-6db867cf4762"}}}}, {"uuid": "fb417fec-33bd-4084-8f82-6d11748f2047", "name": "a9795b2b-4b87-4110-8a14-78afd0d49d64_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.046232297850773, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7285366000251032, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3064bd57-4ffc-4deb-8735-6d075a485d9f", "name": "96357b25-56ee-4f8d-9da2-a3e83610934a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fb417fec-33bd-4084-8f82-6d11748f2047"}}}]}, {"uuid": "e3f43d0b-7c14-40bf-8d16-648e9e170049", "name": "load_p1rlv133_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31dc8280-eb14-4f87-85d7-8eae17013fe7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3064bd57-4ffc-4deb-8735-6d075a485d9f"}}}}, {"uuid": "f985227a-08b1-43a1-8e47-a22acac88d68", "name": "710369ac-a8d0-4c38-93a8-46b84dd1d8a7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.046232297850773, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7285366000251032, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d3331dab-f1a0-40fa-81e9-63713ffc2b94", "name": "f3f63640-6d2d-44e9-9790-fa94d65bf3a0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f985227a-08b1-43a1-8e47-a22acac88d68"}}}]}, {"uuid": "a4597a71-10a4-4e27-b3cf-0a95e3532ec2", "name": "load_p1rlv133_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31dc8280-eb14-4f87-85d7-8eae17013fe7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d3331dab-f1a0-40fa-81e9-63713ffc2b94"}}}}, {"uuid": "c93cb390-e017-4571-8bdc-951a3c7934e2", "name": "09bdff91-2037-4c18-ba7b-a04c66ed49b6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.749950841708346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2019248045205122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c73fef17-c587-4230-b668-dff1db537a28", "name": "154ddc07-d012-4fdd-9991-5b1ca9c716dd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c93cb390-e017-4571-8bdc-951a3c7934e2"}}}]}, {"uuid": "347cf23e-5bb8-4ca9-bf4c-f95fe4d6aed4", "name": "load_p1rlv134_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "425bdcfa-9753-4ef5-bb38-9e014ae779dc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c73fef17-c587-4230-b668-dff1db537a28"}}}}, {"uuid": "a92c0e23-02e5-4950-8be3-f8c9e8c4591d", "name": "2a8bc7d6-7297-4097-8dfd-1c6494a98a65_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.749950841708346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2019248045205122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e19a7870-8be5-4d5e-8652-16b430939a8d", "name": "868745ea-71dc-4326-a57b-7f61af0d2ab9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a92c0e23-02e5-4950-8be3-f8c9e8c4591d"}}}]}, {"uuid": "266eefbd-2122-4ee6-9540-516ad6889ef8", "name": "load_p1rlv134_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "425bdcfa-9753-4ef5-bb38-9e014ae779dc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e19a7870-8be5-4d5e-8652-16b430939a8d"}}}}, {"uuid": "95ec5f2b-b490-42f4-8ee2-9ca02be4da2c", "name": "45df5033-41fe-4d79-b003-347016b718a8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.42648220197083947, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17627708866943506, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d5775010-abb6-406d-84d4-10da14e4a029", "name": "fb2cf978-0429-4a12-969a-5bb046e1aa57", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "95ec5f2b-b490-42f4-8ee2-9ca02be4da2c"}}}]}, {"uuid": "941505d8-b4bb-420d-ad6e-167a2ebd2c3a", "name": "load_p1rlv135_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbdefe7a-517b-495b-88b8-dcf15a9429ff"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d5775010-abb6-406d-84d4-10da14e4a029"}}}}, {"uuid": "bad99740-a014-4f26-bf2e-7387137923c8", "name": "79792ac0-069b-447a-a970-b0bc553883d1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.42648220197083947, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17627708866943506, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50f95d46-0ac6-48ff-95ad-00338df71ef2", "name": "0394e936-e0cc-4fd8-8fcc-9cfc4332f150", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bad99740-a014-4f26-bf2e-7387137923c8"}}}]}, {"uuid": "bc126c2c-755e-4200-8d8f-962a94855b9c", "name": "load_p1rlv135_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbdefe7a-517b-495b-88b8-dcf15a9429ff"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50f95d46-0ac6-48ff-95ad-00338df71ef2"}}}}, {"uuid": "9f3b6ec2-dfbd-409b-a2c6-525a9ff654ff", "name": "39164d37-47d5-414e-8a10-a40a4ab83b24_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.42648220197083947, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17627708866943506, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d0e4956c-feaf-42b5-9ee4-c963a2a26935", "name": "15277c3b-7fa8-4388-a600-0b7f97c905a4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9f3b6ec2-dfbd-409b-a2c6-525a9ff654ff"}}}]}, {"uuid": "2d231a9c-7512-4f43-8277-1487fc229652", "name": "load_p1rlv136_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b45d086e-8e0d-42f4-a8ec-6d3a9579a96b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d0e4956c-feaf-42b5-9ee4-c963a2a26935"}}}}, {"uuid": "fdafdf3b-73b3-453a-87c2-2df8084bb98c", "name": "ca06e9b0-4117-4eff-bf25-bbfe498d6009_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.42648220197083947, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17627708866943506, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9cc6a9b8-8464-4424-b3b3-4d2cc9d97dd5", "name": "25312fce-d271-4992-a5e5-ddb8d59e7ff5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fdafdf3b-73b3-453a-87c2-2df8084bb98c"}}}]}, {"uuid": "1cdcc87f-f562-47be-91b4-f48dd1775575", "name": "load_p1rlv136_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b45d086e-8e0d-42f4-a8ec-6d3a9579a96b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9cc6a9b8-8464-4424-b3b3-4d2cc9d97dd5"}}}}, {"uuid": "0086126c-4d2d-4fc7-96e6-03d8d4cac9d3", "name": "f3fd3a9b-7921-449c-8770-15e549537819_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7847716543397305, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8567239737527961, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "505c74a3-c96f-4c02-a72f-d0f90e0437a1", "name": "a5512df3-8486-4353-af08-2fc11ccb626e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0086126c-4d2d-4fc7-96e6-03d8d4cac9d3"}}}]}, {"uuid": "c16d5956-bcaf-4e19-bbb4-a2d9c7c50985", "name": "load_p1rlv137_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54ca5205-5b71-42f2-8e24-c24f768a7a5c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "505c74a3-c96f-4c02-a72f-d0f90e0437a1"}}}}, {"uuid": "db699610-605d-413c-8ff6-f42b1562e0cf", "name": "286e5f6e-1ae8-4f8b-8acf-22c703327965_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7847716543397305, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8567239737527961, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6a7d692c-a117-4247-8287-b3f354c302fd", "name": "bbcd4a4f-a0ec-4892-93b6-87e6bf5f4997", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "db699610-605d-413c-8ff6-f42b1562e0cf"}}}]}, {"uuid": "b741fa39-d83e-4937-81da-2c267cac540d", "name": "load_p1rlv137_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54ca5205-5b71-42f2-8e24-c24f768a7a5c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6a7d692c-a117-4247-8287-b3f354c302fd"}}}}, {"uuid": "682e5096-46cf-4550-a322-c4ab8b58f66e", "name": "fa81627e-9a5c-4990-b78c-b6a34af2247d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3464174292990054, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8802812503815668, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f4389e8d-94fe-424c-ab95-9398108a0c98", "name": "02f8a4fb-67f2-46db-a057-566bd62223f2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "682e5096-46cf-4550-a322-c4ab8b58f66e"}}}]}, {"uuid": "a13d6162-7194-4ef1-9525-14c7daa057bc", "name": "load_p1rlv138_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea9e5f8c-8477-403c-9d3a-911c4e5ab5c8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f4389e8d-94fe-424c-ab95-9398108a0c98"}}}}, {"uuid": "31687a1d-b0c0-4fdf-b82d-bc308aabefd0", "name": "177ce2f3-6ac7-4c15-946b-12bb54870dea_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3464174292990054, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8802812503815668, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "95e0385d-8d99-4303-b089-6f2829172f7e", "name": "2dc4c056-d7cb-4f5b-a146-5befc5393a1a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "31687a1d-b0c0-4fdf-b82d-bc308aabefd0"}}}]}, {"uuid": "dcd3190d-0b75-48da-8b22-cc7d18a61203", "name": "load_p1rlv138_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea9e5f8c-8477-403c-9d3a-911c4e5ab5c8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "95e0385d-8d99-4303-b089-6f2829172f7e"}}}}, {"uuid": "b1a1e4ef-f08c-4195-99b1-234afd20d768", "name": "d35c880e-0ed2-4c1d-a930-f6984f03b3be_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d041a1dd-add3-4622-b9a3-3318ab972cfa", "name": "785d81d9-4a00-4d38-8461-704019109825", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b1a1e4ef-f08c-4195-99b1-234afd20d768"}}}]}, {"uuid": "9d10a1c4-d3ce-4795-a27d-1d6c70a0f364", "name": "load_p1rlv139_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b515111-3455-471a-aba8-92c82624a195"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d041a1dd-add3-4622-b9a3-3318ab972cfa"}}}}, {"uuid": "659e1f70-3a5c-4fe3-b175-ae2b937d5072", "name": "72b548ea-22ba-43cf-8b60-272236c601e5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "315adfbb-45bd-4aef-b975-b33240c1baaa", "name": "1bc333f7-d58e-4446-a171-8fb28b2036bd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "659e1f70-3a5c-4fe3-b175-ae2b937d5072"}}}]}, {"uuid": "d2dc7c04-36f4-41ec-9710-1fc569efcafc", "name": "load_p1rlv139_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b515111-3455-471a-aba8-92c82624a195"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "315adfbb-45bd-4aef-b975-b33240c1baaa"}}}}, {"uuid": "034b2e6c-75c2-4ec8-b37f-f667c33a99c5", "name": "088bc71c-b927-42da-9b52-f7e65500ea96_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.209150400251685, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2205162973996855, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "19a5d21e-61b9-463f-9019-13b26647196e", "name": "d56465c5-95d2-4be6-bfed-60413c14803f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "034b2e6c-75c2-4ec8-b37f-f667c33a99c5"}}}]}, {"uuid": "5f355174-2450-47b3-8699-e6f5ab544c8c", "name": "load_p1rlv140_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47b7d9f8-ca72-4a77-af67-74ee561f7f10"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "19a5d21e-61b9-463f-9019-13b26647196e"}}}}, {"uuid": "63bb7c2e-c2b4-40b4-b982-f5fa68dd616f", "name": "a7a86684-abbb-4eba-bb58-2664751d69a4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.209150400251685, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2205162973996855, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "15829817-4b74-4da6-8886-2ceb190a7d6a", "name": "26b8d213-19be-48eb-9e30-43b201a201e2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "63bb7c2e-c2b4-40b4-b982-f5fa68dd616f"}}}]}, {"uuid": "078efe7b-e8c2-4b0a-8724-18637fa38f8e", "name": "load_p1rlv140_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47b7d9f8-ca72-4a77-af67-74ee561f7f10"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "15829817-4b74-4da6-8886-2ceb190a7d6a"}}}}, {"uuid": "eda14cb6-5a95-4051-932e-1aaf61b27387", "name": "d6dac862-178a-429b-b99c-fdc55e6ecf30_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.151480398016275, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.11399865992730775, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "44a09194-ef66-4ffc-878e-d75e35308de7", "name": "4ebb344d-82dc-499a-9c40-c415cfc56f7b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eda14cb6-5a95-4051-932e-1aaf61b27387"}}}]}, {"uuid": "fc3a2ef7-4d6c-4256-850a-721c0c740e0d", "name": "load_p1rlv141_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb69a6a9-3eaf-4fc3-82be-0eec77455a82"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "44a09194-ef66-4ffc-878e-d75e35308de7"}}}}, {"uuid": "38871f1f-85b5-4b3b-af00-f94e78fd4eae", "name": "f5a7f030-cd46-44b6-a68d-99662bdd96d6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.151480398016275, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.11399865992730775, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ae6826a1-1972-422c-8398-5a8baefac133", "name": "ad2ef29a-cada-4bf4-a441-2bfd7068ee86", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "38871f1f-85b5-4b3b-af00-f94e78fd4eae"}}}]}, {"uuid": "ca231060-9de7-45a2-b588-e95b9061ebb8", "name": "load_p1rlv141_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb69a6a9-3eaf-4fc3-82be-0eec77455a82"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ae6826a1-1972-422c-8398-5a8baefac133"}}}}, {"uuid": "11514d8b-42b8-44ec-b770-f820efbc3626", "name": "b3b92ae2-3d05-4a7c-b72e-47c331e7a3f2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9029063430901945, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8881818750925909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b0adad72-9bdc-41ec-8a01-baf64e8da41f", "name": "bee29b63-4f88-4222-881d-7ad9afaad9c8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "11514d8b-42b8-44ec-b770-f820efbc3626"}}}]}, {"uuid": "c9a36645-5b3b-40d0-853e-4c24719fea23", "name": "load_p1rlv143_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "46cd88d0-b2c4-492a-af3d-d9ae886d0089"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b0adad72-9bdc-41ec-8a01-baf64e8da41f"}}}}, {"uuid": "8e1d9cc7-4be8-4426-beb6-ad38017a7ab5", "name": "8e55faaf-86ba-45d3-9a60-33e353e2969a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9029063430901945, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8881818750925909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b5c00744-639c-41ea-96ca-c1f09800fc3a", "name": "66ff36d7-5b31-4475-84ee-e223b11c1d90", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8e1d9cc7-4be8-4426-beb6-ad38017a7ab5"}}}]}, {"uuid": "b13f3e78-16f0-46ea-a28a-6bd223312662", "name": "load_p1rlv143_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "46cd88d0-b2c4-492a-af3d-d9ae886d0089"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b5c00744-639c-41ea-96ca-c1f09800fc3a"}}}}, {"uuid": "6efba862-2084-4197-8842-7a4e3e7cbe55", "name": "ca51752d-e464-48b4-89bb-3cab4889764a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9024769844937937, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4778358547008617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4618b6bb-3217-4c40-81e5-337da883d284", "name": "d6d818ce-0039-4dc7-92b2-95d506c66f3d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6efba862-2084-4197-8842-7a4e3e7cbe55"}}}]}, {"uuid": "6dfbe3aa-d122-4dd0-adae-a501ba9ce94f", "name": "load_p1rlv144_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b7dbf54-f6bc-4e20-b2f3-8c63a44dd993"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4618b6bb-3217-4c40-81e5-337da883d284"}}}}, {"uuid": "9b3d7385-18b7-4c12-87d4-28509ac71622", "name": "8b41385c-d319-435b-878e-1abaaf86169d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9024769844937937, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4778358547008617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cfddae17-0b75-403e-8c4b-abf94636a6da", "name": "bd484a3e-574e-4959-9058-98b297b870ba", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9b3d7385-18b7-4c12-87d4-28509ac71622"}}}]}, {"uuid": "651d58ec-8f41-4a45-87bf-325c1f4cd4ab", "name": "load_p1rlv144_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b7dbf54-f6bc-4e20-b2f3-8c63a44dd993"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cfddae17-0b75-403e-8c4b-abf94636a6da"}}}}, {"uuid": "596e3b96-2e23-4f01-90df-cd04c0f0f94c", "name": "a681cdc9-4b50-46b7-8c08-2d8bffbb7144_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5478654763148745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5646840796232575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "64174510-2d82-4a24-91df-ec21ad651c75", "name": "94f59b95-5d40-449e-982f-797659492681", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "596e3b96-2e23-4f01-90df-cd04c0f0f94c"}}}]}, {"uuid": "2c8ea63a-1b5f-4324-8f57-3190d9421025", "name": "load_p1rlv145_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1704e67-dfa3-4a6b-a3f4-7ebba9d27537"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "64174510-2d82-4a24-91df-ec21ad651c75"}}}}, {"uuid": "26401bca-ca42-4b35-96cb-c083a9c82b1e", "name": "40b6c346-3a2f-4b29-a7b6-747e501f9941_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5478654763148745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5646840796232575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c752fc03-cc98-431f-bdef-07b64f2c5114", "name": "7fd9d5e3-d134-4162-8ad5-5b57c4b8eb78", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "26401bca-ca42-4b35-96cb-c083a9c82b1e"}}}]}, {"uuid": "033e9386-a8ca-41a0-b92b-a0e2abb19756", "name": "load_p1rlv145_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1704e67-dfa3-4a6b-a3f4-7ebba9d27537"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c752fc03-cc98-431f-bdef-07b64f2c5114"}}}}, {"uuid": "b304661b-8f12-449a-8f41-f02a8a8c80e2", "name": "9e58965c-d189-4f80-86fe-7f5fb1bf3fcf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8309189378455104, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6069744647018672, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a64c60f-711f-4c47-ad03-c64950c901a1", "name": "2e28f36a-4df6-4074-806a-a131dde98fd9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b304661b-8f12-449a-8f41-f02a8a8c80e2"}}}]}, {"uuid": "b2e7ecf7-0e4c-444d-8662-2650fcbbdf78", "name": "load_p1rlv146_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da2538bd-189b-4699-823b-ed459d94b422"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a64c60f-711f-4c47-ad03-c64950c901a1"}}}}, {"uuid": "c0bafccd-dcf8-4967-8689-6d2494d0b36c", "name": "2c66c959-d921-48eb-b2fe-7f3c076980f0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8309189378455104, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6069744647018672, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6fdf8d05-e64c-493f-945d-164885fb3387", "name": "fd78a750-5fc4-431b-bf2f-b6cdba25cfd6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c0bafccd-dcf8-4967-8689-6d2494d0b36c"}}}]}, {"uuid": "23482389-4769-43fa-8b5f-093a6f1dbc66", "name": "load_p1rlv146_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da2538bd-189b-4699-823b-ed459d94b422"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6fdf8d05-e64c-493f-945d-164885fb3387"}}}}, {"uuid": "d96d1306-0ca2-444f-bd3a-14e7ce69c39c", "name": "79ef7648-0e4f-47f3-9552-070c1daf8b7e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.3355603190645935, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9435041304985261, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4e188817-c68e-43ff-b1b3-d8b89b6313f8", "name": "2e1300a2-b142-4cf7-b428-44ae641f3b33", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d96d1306-0ca2-444f-bd3a-14e7ce69c39c"}}}]}, {"uuid": "44fd75f0-0108-48e9-91b3-66e8bd787b59", "name": "load_p1rlv147_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "070d9a60-c6f2-424c-bd0f-66c52d349f0c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4e188817-c68e-43ff-b1b3-d8b89b6313f8"}}}}, {"uuid": "4f99e19b-0c10-4aa1-a8d2-49724a8051ad", "name": "6d8d7835-2274-4924-9a05-990a5b79ed12_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.3355603190645935, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9435041304985261, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "56054ae6-3682-47ac-a664-23bb779230da", "name": "2dbd413d-f2d8-468d-9705-7dd87674f442", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4f99e19b-0c10-4aa1-a8d2-49724a8051ad"}}}]}, {"uuid": "bcbb05e5-afc4-4792-87d5-52bea1b4b377", "name": "load_p1rlv147_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "070d9a60-c6f2-424c-bd0f-66c52d349f0c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "56054ae6-3682-47ac-a664-23bb779230da"}}}}, {"uuid": "58883f3e-fe3f-4f4a-b34b-a98fbc741f50", "name": "f46cb48f-eaaa-4ffb-9352-6dc4011d0fbb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8322096344455547, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7991596594888891, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "467b71c4-89b2-41bb-a169-4113dd36049d", "name": "2f7cc6c9-2406-41b0-a256-0bf75d1c8276", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58883f3e-fe3f-4f4a-b34b-a98fbc741f50"}}}]}, {"uuid": "6592f31a-023d-4bb6-bff2-43300edf4703", "name": "load_p1rlv148_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa8af0a4-4d55-41e4-83d1-4fe349920e38"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "467b71c4-89b2-41bb-a169-4113dd36049d"}}}}, {"uuid": "f3b31322-4a81-4bd1-81b9-bcc2afe6fdf5", "name": "4dffbdd2-5c5c-4770-bd8d-35347cb4a8c6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8322096344455547, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7991596594888891, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b2180f75-44f0-42d8-88f3-f1346b5158b9", "name": "abba6f94-a44b-4def-8331-63b5e15689d0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f3b31322-4a81-4bd1-81b9-bcc2afe6fdf5"}}}]}, {"uuid": "222251ff-23fc-4c53-b67b-5d791152038f", "name": "load_p1rlv148_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa8af0a4-4d55-41e4-83d1-4fe349920e38"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b2180f75-44f0-42d8-88f3-f1346b5158b9"}}}}, {"uuid": "b18a0e35-3710-4ac6-8659-b140bcddb054", "name": "0f329b93-21bb-46c9-81b6-04efa26cb4d7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4856814769108864, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8267323554826451, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c299fdab-1be2-44cc-96e2-6818b024cf1a", "name": "7a46dd14-b0c7-4773-90e5-a77125b014aa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b18a0e35-3710-4ac6-8659-b140bcddb054"}}}]}, {"uuid": "7d8e659d-c80b-4311-97a0-4bccb4c72934", "name": "load_p1rlv149_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "063e89ea-6dd0-404f-abfb-21686f3041ed"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c299fdab-1be2-44cc-96e2-6818b024cf1a"}}}}, {"uuid": "d9f6edac-f43c-41d2-9855-3e5d321a5557", "name": "c29d21b1-bfc1-401b-98a6-fdb5f43c054f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4856814769108864, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8267323554826451, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c7ac34c1-7a2f-4670-8fc2-8f72b68d431a", "name": "be672881-04e7-4295-b56d-1fd88d691219", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d9f6edac-f43c-41d2-9855-3e5d321a5557"}}}]}, {"uuid": "9b6cbfe0-93bd-470e-a7c2-b85265e317a0", "name": "load_p1rlv149_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "063e89ea-6dd0-404f-abfb-21686f3041ed"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c7ac34c1-7a2f-4670-8fc2-8f72b68d431a"}}}}, {"uuid": "2755d3e5-9a94-44af-9a22-f04a395f82bd", "name": "77049928-0e3f-4ffa-a8eb-edc8a66ec445_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4363904318707768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7717292253609904, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6bf52870-b994-4ac6-a78e-f09d89990a8e", "name": "7d6ae7c1-3b27-41a7-bd5b-17fbd7f49a36", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2755d3e5-9a94-44af-9a22-f04a395f82bd"}}}]}, {"uuid": "c9162abe-7b46-4442-b723-313a2f140b94", "name": "load_p1rlv150_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b9979ec-4e43-4feb-a617-28191e9dd9d8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6bf52870-b994-4ac6-a78e-f09d89990a8e"}}}}, {"uuid": "cc94c4fb-e6d2-4258-99f2-80cc480e81f8", "name": "56adb619-83e9-403c-b508-c29461a2acdf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4363904318707768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7717292253609904, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "923dac6e-dac9-4b6a-88b9-f90ce0af4d15", "name": "12e1cf39-01d8-4998-9719-5ff883dbd7c5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cc94c4fb-e6d2-4258-99f2-80cc480e81f8"}}}]}, {"uuid": "38d8ebb4-802c-4053-9ffc-dad485aa76c3", "name": "load_p1rlv150_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b9979ec-4e43-4feb-a617-28191e9dd9d8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "923dac6e-dac9-4b6a-88b9-f90ce0af4d15"}}}}, {"uuid": "4a96dd5c-c1cf-4bda-8faa-6c177cac16a0", "name": "6cdc4319-9a33-4da3-a140-3084bd8675d2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.371919551924291, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7891526087442801, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e6169458-cf82-4d24-9754-3f8c1bd6a7fc", "name": "045e2802-f6e2-4e20-8056-bdb6b7c4142f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4a96dd5c-c1cf-4bda-8faa-6c177cac16a0"}}}]}, {"uuid": "0cda9978-67ba-4878-a11b-9c6683e1b644", "name": "load_p1rlv151_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "345b5c48-cd35-418e-bc08-50c06f5dff09"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e6169458-cf82-4d24-9754-3f8c1bd6a7fc"}}}}, {"uuid": "fd0d566a-eb29-49c1-b499-db0fef89ceeb", "name": "410cbe2a-d7b3-412a-b5a5-1d5e77cbc28c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.371919551924291, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7891526087442801, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "24d62fae-b96b-411a-a99a-e92cb4e74a46", "name": "bb1f18f6-0cad-4534-b8bd-2d97729aef38", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fd0d566a-eb29-49c1-b499-db0fef89ceeb"}}}]}, {"uuid": "43d28bc8-e7f1-4742-8311-292f1796ff7c", "name": "load_p1rlv151_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "345b5c48-cd35-418e-bc08-50c06f5dff09"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "24d62fae-b96b-411a-a99a-e92cb4e74a46"}}}}, {"uuid": "bb9f90a6-0e2c-480b-abaf-2caaf59df40d", "name": "b55ad8a0-3c28-4dad-be50-b52c8aad5aef_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1381537134701794, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42848704523913217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6aa1373f-1958-42b9-8eb0-2aa8619f5abb", "name": "96966198-f951-452f-9a42-229b7fd330b1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bb9f90a6-0e2c-480b-abaf-2caaf59df40d"}}}]}, {"uuid": "1a727775-9d19-408b-aa4a-28ef8bac6e71", "name": "load_p1rlv152_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25b891ce-797a-4a4d-b664-4225fba806c4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6aa1373f-1958-42b9-8eb0-2aa8619f5abb"}}}}, {"uuid": "50d91c7a-0fab-42dd-9308-c8d005ab6688", "name": "351c5236-9e35-4471-833c-dc9da4e7e306_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1381537134701794, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42848704523913217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4cb66431-8190-4793-9e90-23f1cdb1cb25", "name": "7f716e77-1e2b-4a56-95cb-dc1a96d25136", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "50d91c7a-0fab-42dd-9308-c8d005ab6688"}}}]}, {"uuid": "21fe823b-b24d-4c2c-a164-eb7bf5f9c199", "name": "load_p1rlv152_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25b891ce-797a-4a4d-b664-4225fba806c4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4cb66431-8190-4793-9e90-23f1cdb1cb25"}}}}, {"uuid": "ad038307-bf63-4325-aaf3-7073f33fc11c", "name": "41412b4d-fb58-44a6-af9d-eac87b314ace_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.567401274738218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6497123013243786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9589c15d-3d6c-4085-a001-b653159fda79", "name": "a02eb120-8919-40e8-9966-15fa07f620d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ad038307-bf63-4325-aaf3-7073f33fc11c"}}}]}, {"uuid": "3ad36ef3-8756-4f87-937c-8b411a17f018", "name": "load_p1rlv153_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ebbe09dd-7560-4eff-9e32-803f14b4ce7c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9589c15d-3d6c-4085-a001-b653159fda79"}}}}, {"uuid": "3d6b9794-cc04-4a3c-8508-8c264e5770c7", "name": "b1908562-73cc-4fb3-aad9-109c6f7b8693_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.567401274738218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6497123013243786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "28f9d670-2046-4464-aebf-afde5cb96ba4", "name": "c59fabc3-bbb0-4ff5-99d0-a1e491b30a5e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3d6b9794-cc04-4a3c-8508-8c264e5770c7"}}}]}, {"uuid": "88e1d099-0fe2-4cf9-9696-2cd72fa5929d", "name": "load_p1rlv153_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ebbe09dd-7560-4eff-9e32-803f14b4ce7c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "28f9d670-2046-4464-aebf-afde5cb96ba4"}}}}, {"uuid": "ff01f4eb-995f-4752-b365-bba2b9223d49", "name": "4dc3d221-3521-416a-b5e5-46ff24f0c3e1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6235247805381197, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5206515777483778, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "47d88b93-6ce7-4903-bac2-9c34abcdfe9e", "name": "de3bf5d6-9721-4ffb-96a8-2dde7c116d90", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ff01f4eb-995f-4752-b365-bba2b9223d49"}}}]}, {"uuid": "fe71efd1-7d64-4c4a-ac74-446d584f4c5e", "name": "load_p1rlv154_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ccdfbc7-d3a6-4f74-ad32-25ff11a2e3b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "47d88b93-6ce7-4903-bac2-9c34abcdfe9e"}}}}, {"uuid": "0614c34a-114c-40d2-a8c2-2d1a046eeed4", "name": "99ae88cc-c8fe-4c25-9c77-2dbe4f065ce2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6235247805381197, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5206515777483778, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "addce10f-e9ee-486f-b31b-e941253493a8", "name": "b453f214-b5c5-42a8-837e-0a729f59b610", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0614c34a-114c-40d2-a8c2-2d1a046eeed4"}}}]}, {"uuid": "8c98171c-35a4-4280-bc3b-6e54c2785507", "name": "load_p1rlv154_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ccdfbc7-d3a6-4f74-ad32-25ff11a2e3b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "addce10f-e9ee-486f-b31b-e941253493a8"}}}}, {"uuid": "5fd7bfc3-e074-4c73-af9b-c9afd6066292", "name": "551775ff-9f39-42b0-830d-e330ac2d1791_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.108706484347092, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9298438232381894, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f6a57a7d-a667-482a-be6f-e450371abb29", "name": "aeea7305-281e-4470-af56-a22592c1c7ff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5fd7bfc3-e074-4c73-af9b-c9afd6066292"}}}]}, {"uuid": "18f9ee3a-9c84-4710-beab-a5bb978ec532", "name": "load_p1rlv155_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2452d5af-5aba-4d4b-8cd9-27a95fe6b34d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f6a57a7d-a667-482a-be6f-e450371abb29"}}}}, {"uuid": "3a47ae95-d7cb-4523-93c2-230fb065d89b", "name": "c95d57ba-4cf0-4346-bd63-3f17baf8f9cb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.108706484347092, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9298438232381894, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e6a822a7-b8d1-4bb4-9a75-ab11afaa184f", "name": "d725a57f-a94b-41c7-a169-d697f57dadb1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3a47ae95-d7cb-4523-93c2-230fb065d89b"}}}]}, {"uuid": "8e9ded2b-34fc-4efa-8c3c-dca36a27429a", "name": "load_p1rlv155_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2452d5af-5aba-4d4b-8cd9-27a95fe6b34d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e6a822a7-b8d1-4bb4-9a75-ab11afaa184f"}}}}, {"uuid": "948fd41c-89a2-42c7-af9e-4063c6d0b180", "name": "fc5973c9-b174-43c4-8cdf-7a83995d7b04_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7537427041030689, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.37349948863112625, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "abf8107a-a30b-4316-a765-541a893ce591", "name": "c1c669b4-f5a0-43c9-968d-302e6cb121e3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "948fd41c-89a2-42c7-af9e-4063c6d0b180"}}}]}, {"uuid": "5d8cfb02-36f5-4d97-980b-1c7bedf17ccf", "name": "load_p1rlv156_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f607e6b-9540-4845-9f0c-6c334eb0e807"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "abf8107a-a30b-4316-a765-541a893ce591"}}}}, {"uuid": "935ef1c3-72e1-436e-bc15-f545f6b403df", "name": "5191cadc-6d3e-48d3-8e78-1380f62e6742_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7537427041030689, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.37349948863112625, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82073bd9-631c-47e5-9919-c1b48349e72d", "name": "469bcafc-5ecb-4cc8-890e-900f450020c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "935ef1c3-72e1-436e-bc15-f545f6b403df"}}}]}, {"uuid": "9db2b8c0-d340-498e-859f-41389b498e69", "name": "load_p1rlv156_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f607e6b-9540-4845-9f0c-6c334eb0e807"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "82073bd9-631c-47e5-9919-c1b48349e72d"}}}}, {"uuid": "bbb9af72-1b21-4719-acda-ff7ca257537b", "name": "fdb83a04-3f11-4a69-8f2d-ca418085afcd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.095937077188644, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9158391685680531, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10e19920-3702-415e-83da-bc6eb9517f3d", "name": "78eb2ff1-0b89-4b2a-85b9-3fe469d614d9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bbb9af72-1b21-4719-acda-ff7ca257537b"}}}]}, {"uuid": "5f7c3981-32f3-4b90-bed6-25b9d01fc927", "name": "load_p1rlv157_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4355a473-4643-4f72-afe8-80ce773ca8e8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10e19920-3702-415e-83da-bc6eb9517f3d"}}}}, {"uuid": "175e92fa-a479-4df5-b9c0-237f7d031d69", "name": "3d0ce575-376f-4ba3-a146-4f3a1499a5e3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.095937077188644, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9158391685680531, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7a5f84b4-faf1-4cf8-8940-65f8f657c018", "name": "2c3d94ef-3441-4046-9dc3-92fa55fe52a1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "175e92fa-a479-4df5-b9c0-237f7d031d69"}}}]}, {"uuid": "fbe3ca78-571d-4ae4-860f-991921cbbcaf", "name": "load_p1rlv157_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4355a473-4643-4f72-afe8-80ce773ca8e8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7a5f84b4-faf1-4cf8-8940-65f8f657c018"}}}}, {"uuid": "8cdd07ea-28f2-4a13-9de0-e26993ff5341", "name": "4ee96c19-3806-4064-94b6-eeb44c18e551_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8840297592093247, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9532534150802011, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "899d4299-2a0e-4ae5-b0b9-1390e0fcc535", "name": "d78e16a0-bffa-49d7-ac9b-8b36e97e82d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8cdd07ea-28f2-4a13-9de0-e26993ff5341"}}}]}, {"uuid": "8de3c047-03a9-4aba-9e64-f6ab42a642a6", "name": "load_p1rlv158_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1cd7284-17fb-4382-a29d-dd8c5bfd7541"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "899d4299-2a0e-4ae5-b0b9-1390e0fcc535"}}}}, {"uuid": "0c8d86db-65a9-4c7d-af73-c853594251e4", "name": "3eb1bae5-9be0-415d-844d-fc6a79d0ac7e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8840297592093247, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9532534150802011, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "778bb6f1-53ee-4071-b98f-50c7a63b20a1", "name": "4146d0a9-becf-474c-90ce-ea5b8fc8844e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0c8d86db-65a9-4c7d-af73-c853594251e4"}}}]}, {"uuid": "e41e26d9-4dcc-4f50-ac1a-dc1a9f2fdeed", "name": "load_p1rlv158_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1cd7284-17fb-4382-a29d-dd8c5bfd7541"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "778bb6f1-53ee-4071-b98f-50c7a63b20a1"}}}}, {"uuid": "d68b2e1c-0cbf-46c4-913b-f7d400006ae7", "name": "9f845cf9-8a36-4ec0-bba1-3983a908f7e8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.374654272561421, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4772638197977597, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e6f5f0bb-c625-4ae5-80f5-ea8be9ed6188", "name": "27cc8d66-ef3e-4ce0-bd01-0b412d29c7b7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d68b2e1c-0cbf-46c4-913b-f7d400006ae7"}}}]}, {"uuid": "83135160-8d59-48d8-89f3-a13a2e5a666d", "name": "load_p1rlv159_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0ae6c02-c29e-4bf9-b1d4-ecc7e37e7de2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e6f5f0bb-c625-4ae5-80f5-ea8be9ed6188"}}}}, {"uuid": "3cfea8c2-b638-47d9-b2ac-ef32e676f050", "name": "1b8759f5-240f-4f14-bb73-b120b24050f6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.374654272561421, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4772638197977597, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c5d16f5c-a56f-4d89-9ba4-0e87a25ae1e4", "name": "9632e604-abee-4381-a8da-ef8a40bb3c5d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3cfea8c2-b638-47d9-b2ac-ef32e676f050"}}}]}, {"uuid": "3c29eda9-ab0f-4b5b-998f-68e75fdc6376", "name": "load_p1rlv159_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0ae6c02-c29e-4bf9-b1d4-ecc7e37e7de2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c5d16f5c-a56f-4d89-9ba4-0e87a25ae1e4"}}}}, {"uuid": "b9ddc7cb-eb34-46b9-8a35-4504b55c290c", "name": "7428b4e2-67cc-42de-88ea-cbee112a2d17_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.442421826038779, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9571745396829384, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6c0b14c3-394b-4868-b1d3-5d7e95265052", "name": "bb27f7e2-8d35-46f2-a528-59ef9a686b87", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b9ddc7cb-eb34-46b9-8a35-4504b55c290c"}}}]}, {"uuid": "f9560b22-0982-4d00-8b31-a029346a264e", "name": "load_p1rlv160_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd2fae5a-e5dd-4ad4-8acc-422de00ae83e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6c0b14c3-394b-4868-b1d3-5d7e95265052"}}}}, {"uuid": "af343575-9b10-43f2-9a7b-35f179fb9685", "name": "2970a6c2-819e-455d-a867-daa7338e6234_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.442421826038779, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9571745396829384, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c5f5f382-7b6d-4bae-a150-b970b5ee303f", "name": "ea134b02-0b2f-4a4f-be02-7a0cd5401977", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "af343575-9b10-43f2-9a7b-35f179fb9685"}}}]}, {"uuid": "8133c7b7-4525-4ca0-a609-363f6efc7d54", "name": "load_p1rlv160_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd2fae5a-e5dd-4ad4-8acc-422de00ae83e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c5f5f382-7b6d-4bae-a150-b970b5ee303f"}}}}, {"uuid": "328d8c3e-0611-4a1e-b691-dc74728b29c5", "name": "af682978-efe2-47c9-a254-c3c11fc0d851_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0ff97ff9-a544-4896-8d12-a2f3de1ce723", "name": "589c8a5d-0a70-4a9c-9b5b-8a80a9d0e905", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "328d8c3e-0611-4a1e-b691-dc74728b29c5"}}}]}, {"uuid": "0628e2d9-5b47-44ae-87b3-22c5f8b928e3", "name": "load_p1rlv161_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4842819e-3f17-47da-a8bf-c3402c3c00b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0ff97ff9-a544-4896-8d12-a2f3de1ce723"}}}}, {"uuid": "8a242f35-2441-445f-8acf-0276263fed46", "name": "25040100-e180-4f0b-8556-982cff6f28b8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bfc0ef6d-9d70-45f9-b448-da730be6008c", "name": "195665b6-661d-4ba2-b416-f11523a8957c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a242f35-2441-445f-8acf-0276263fed46"}}}]}, {"uuid": "9f3ac376-58ea-4e67-860a-22cb60ee101b", "name": "load_p1rlv161_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4842819e-3f17-47da-a8bf-c3402c3c00b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bfc0ef6d-9d70-45f9-b448-da730be6008c"}}}}, {"uuid": "0c866a74-80b4-4de8-ab0f-8af6d5e99cc7", "name": "0d2de203-31e0-414e-86dd-b5ecdf23e2ed_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8374792851175116, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3203908676737591, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2dd7a99d-e8de-47c1-9d13-4bf7dd8f3b77", "name": "9df39120-b9c3-4747-bddc-d26981985449", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0c866a74-80b4-4de8-ab0f-8af6d5e99cc7"}}}]}, {"uuid": "cdccd113-7867-400e-9bfc-673b6504e025", "name": "load_p1rlv162_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3fcd1ee-e6e0-4ca3-aacf-cc527b07482a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2dd7a99d-e8de-47c1-9d13-4bf7dd8f3b77"}}}}, {"uuid": "d2422cd1-af9d-45dc-8c9c-7288cfc5a26b", "name": "bde66f82-50c0-41b3-b680-4d7bddd49d6e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8374792851175116, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3203908676737591, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0f1052fb-c159-459d-bf3e-737a269fb736", "name": "d2e1b2a4-fcf6-4c91-a810-c2e59000da86", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d2422cd1-af9d-45dc-8c9c-7288cfc5a26b"}}}]}, {"uuid": "b329cd69-c9b0-4878-ac79-27870fdbbe7e", "name": "load_p1rlv162_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3fcd1ee-e6e0-4ca3-aacf-cc527b07482a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0f1052fb-c159-459d-bf3e-737a269fb736"}}}}, {"uuid": "96517525-e2c4-4d6d-aa67-3c78f0ede687", "name": "6c840f55-ebfd-43cc-9769-381ffbf540d5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.255903801273714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9789336651099453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f698c194-b969-456c-9959-4ebbdb8258f3", "name": "98aae7db-d220-421a-acee-cdddcf98741b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "96517525-e2c4-4d6d-aa67-3c78f0ede687"}}}]}, {"uuid": "008c43f1-f5ea-44de-b929-426e8ea6a8ac", "name": "load_p1rlv163_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "471bad88-4514-4b02-aa1a-1d2aaa15557f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f698c194-b969-456c-9959-4ebbdb8258f3"}}}}, {"uuid": "156e6d01-cde8-4bc7-a0cc-ba85375c0343", "name": "0dd99461-0697-4bf2-90a3-f24b43c866bf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.255903801273714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9789336651099453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10d3b8af-7878-4ddd-a72f-04d0d6d5de38", "name": "9fe24db1-0e1e-490c-8da4-76b48f4d9ed3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "156e6d01-cde8-4bc7-a0cc-ba85375c0343"}}}]}, {"uuid": "b5ba124b-48a8-4202-9869-3c0a2845cefa", "name": "load_p1rlv163_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "471bad88-4514-4b02-aa1a-1d2aaa15557f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10d3b8af-7878-4ddd-a72f-04d0d6d5de38"}}}}, {"uuid": "ae092096-ac18-4e26-8ec9-767664b6f311", "name": "469ae3f3-b681-4f98-a225-2dfd2453a804_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.634023352191214, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2934174607236286, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "11d28751-2dc2-4643-ade5-056105ccf36c", "name": "0b58701e-29db-4654-93f6-13763353b25f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ae092096-ac18-4e26-8ec9-767664b6f311"}}}]}, {"uuid": "b4e237d5-30ca-442d-8332-301533b55a01", "name": "load_p1rlv164_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61460072-bdc5-4a70-96fa-8ecfa71623f4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "11d28751-2dc2-4643-ade5-056105ccf36c"}}}}, {"uuid": "b59962b8-410d-4873-8558-4dbe02ecb8fe", "name": "a0671619-9046-42c9-b892-98a56904909a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.634023352191214, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2934174607236286, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dc46ae19-b1eb-4477-87fb-ee2ba7499455", "name": "154e2be4-cb1f-478b-9e94-8f93b38d66c4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b59962b8-410d-4873-8558-4dbe02ecb8fe"}}}]}, {"uuid": "1b646ba1-bbb4-4502-b283-b240fdd81ce4", "name": "load_p1rlv164_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61460072-bdc5-4a70-96fa-8ecfa71623f4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dc46ae19-b1eb-4477-87fb-ee2ba7499455"}}}}, {"uuid": "bb4fa101-0970-45f9-a5db-ebad81aacb1c", "name": "8361d8ec-a547-4a5a-8787-e617c97ed8fb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.916354724025409, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9016755043678467, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3f4de5dd-749e-4e87-909a-e035a519fcdd", "name": "cc92d500-45e7-42e1-ae9b-13d8bb2f2fff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bb4fa101-0970-45f9-a5db-ebad81aacb1c"}}}]}, {"uuid": "0b35ffa2-4fa3-4ab2-84fa-08aaa61760c4", "name": "load_p1rlv165_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e7880c9-0932-4395-abf9-2274e400f280"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3f4de5dd-749e-4e87-909a-e035a519fcdd"}}}}, {"uuid": "d3f6d1d9-b892-4800-b2a5-7dad65648d40", "name": "96e6e68a-0043-4f91-9a2a-5b6b8b9aa970_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.916354724025409, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9016755043678467, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1d03c60f-63b8-4b5a-baba-e7e71a7e9690", "name": "ce24492e-0581-4b7b-918c-0c97ae277ba3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d3f6d1d9-b892-4800-b2a5-7dad65648d40"}}}]}, {"uuid": "468330c1-1a98-49d0-9b35-871faab87fbc", "name": "load_p1rlv165_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e7880c9-0932-4395-abf9-2274e400f280"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1d03c60f-63b8-4b5a-baba-e7e71a7e9690"}}}}, {"uuid": "768dc0db-9dfb-47b2-aac9-7217b1b0cbee", "name": "dc3081f4-2919-49bb-96a1-2f070a62ebc3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0137187800791063, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5284248988065299, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d9c6e84e-8f73-401c-88e7-e518034cdd97", "name": "4934d0b2-27f2-4f83-a544-8afa0eb732ae", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "768dc0db-9dfb-47b2-aac9-7217b1b0cbee"}}}]}, {"uuid": "0c371311-d835-4725-93c2-38caf4340198", "name": "load_p1rlv166_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21d333f7-7426-4fa6-8ab2-c6118055ece1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d9c6e84e-8f73-401c-88e7-e518034cdd97"}}}}, {"uuid": "085d4979-f0e8-4a81-b766-4edceb93e79e", "name": "bf77bda4-8aa9-4eba-89dd-84980b634d82_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0137187800791063, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5284248988065299, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b0114f8e-42b3-4cf6-bf82-0b5a74d34435", "name": "585e8691-2f0c-4b61-84c7-c44b11f02892", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "085d4979-f0e8-4a81-b766-4edceb93e79e"}}}]}, {"uuid": "4842b8c9-483a-4000-b8e4-e92115d3362f", "name": "load_p1rlv166_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21d333f7-7426-4fa6-8ab2-c6118055ece1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b0114f8e-42b3-4cf6-bf82-0b5a74d34435"}}}}, {"uuid": "e3d3f347-2cc5-4163-b195-f4feba41a7fd", "name": "76df4f4c-e521-4730-8e19-8b809222dc22_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.438316346451239, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6915244213249778, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bad3c5a9-944e-4467-ae32-a39f8d2467de", "name": "98d01b2b-b1f1-4250-9f1d-41f70ff5d409", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e3d3f347-2cc5-4163-b195-f4feba41a7fd"}}}]}, {"uuid": "edf53ba9-4c8d-48d7-8acc-70d10e07dd76", "name": "load_p1rlv167_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5187e006-621e-4c15-9604-0272ae62887c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bad3c5a9-944e-4467-ae32-a39f8d2467de"}}}}, {"uuid": "f4199876-e02c-443b-8a34-a7b5569f45be", "name": "52482e87-111f-48b8-acd8-e110e76daa7d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.438316346451239, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6915244213249778, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "549f4461-fd8e-4e37-b9ef-b0d574c9ce4d", "name": "793f7997-5e15-45b1-9c9c-14738a369d89", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f4199876-e02c-443b-8a34-a7b5569f45be"}}}]}, {"uuid": "c9d4f26a-59c2-47b0-82c3-cad585ad2f67", "name": "load_p1rlv167_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5187e006-621e-4c15-9604-0272ae62887c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "549f4461-fd8e-4e37-b9ef-b0d574c9ce4d"}}}}, {"uuid": "8214ae9e-a98a-47c7-bf7a-310a375c354b", "name": "d0eb3fa8-a282-44f2-8e59-84f3c3ccbabd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.639612501586281, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0977377571892493, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6742fd24-2bc0-431d-b30d-4dc763353622", "name": "ef806c3e-41af-4e54-9db4-fd35effb1c39", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8214ae9e-a98a-47c7-bf7a-310a375c354b"}}}]}, {"uuid": "9cf5e44e-7289-461c-87bd-47979c4da230", "name": "load_p1rlv168_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "470fe3ed-5b24-438a-ba6d-cdd9f774e5ad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6742fd24-2bc0-431d-b30d-4dc763353622"}}}}, {"uuid": "3cb772b7-4657-4d8c-b525-85caf30002e2", "name": "166a84a5-46bf-463f-a30d-ac639c12ef84_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.639612501586281, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0977377571892493, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1a1b7a21-7a66-4d44-a8a0-09649c122699", "name": "3cef0015-9633-4bbc-97cd-151780b2104d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3cb772b7-4657-4d8c-b525-85caf30002e2"}}}]}, {"uuid": "6cab2d7f-7acf-4f13-a544-9b4d10e51b6e", "name": "load_p1rlv168_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "470fe3ed-5b24-438a-ba6d-cdd9f774e5ad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1a1b7a21-7a66-4d44-a8a0-09649c122699"}}}}, {"uuid": "383399fd-31e7-4be4-99a8-6525097749ec", "name": "43b935d3-1a10-4adf-9410-46944594ccb7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.684904254134122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42635901069761617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f44b0661-5eed-4671-8837-51e4c5c01de3", "name": "d59b11a3-8cb6-49c5-95c5-60f8d1118f4b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "383399fd-31e7-4be4-99a8-6525097749ec"}}}]}, {"uuid": "1fd860c2-0753-45b8-baa9-3dc334d13763", "name": "load_p1rlv169_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e326756-7ead-4099-a065-9f2de5693197"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f44b0661-5eed-4671-8837-51e4c5c01de3"}}}}, {"uuid": "eeae9ebe-ad30-4b1e-b628-12e620aa68ec", "name": "3718c088-26e2-46ec-8ae8-2a1e26017e5f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.684904254134122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42635901069761617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fb2e612d-b1e6-4bc5-984a-fa6fe8fb9df5", "name": "2772f810-9754-4bd1-9c53-5e888bfd626a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eeae9ebe-ad30-4b1e-b628-12e620aa68ec"}}}]}, {"uuid": "9dc019fb-8428-44bd-a4e0-82641341dbcd", "name": "load_p1rlv169_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e326756-7ead-4099-a065-9f2de5693197"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fb2e612d-b1e6-4bc5-984a-fa6fe8fb9df5"}}}}, {"uuid": "1bd5db0e-8d36-4d2c-b7c0-993a45f5424c", "name": "c90b3a0a-1417-4e01-974d-e7498f6e4231_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7812856221781264, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.29493523962554685, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c16e7813-54ab-4d3e-b29f-e5b94c25edef", "name": "91b96749-f6a7-4aaa-8ef1-27ee7f1d7098", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1bd5db0e-8d36-4d2c-b7c0-993a45f5424c"}}}]}, {"uuid": "4b2fd52a-2379-40cc-b0e7-5233f221bf47", "name": "load_p1rlv170_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f7dbd18-1cbe-49d3-b490-3c46cf8e37f1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c16e7813-54ab-4d3e-b29f-e5b94c25edef"}}}}, {"uuid": "59335f20-1ff3-4163-8844-d0bccb5c1dd8", "name": "fd8c620e-38b3-4a2f-8207-a0ec2ba4c534_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7812856221781264, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.29493523962554685, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c7a14033-b9a3-4231-8824-61308ee49db0", "name": "ed26bab6-3b3c-4663-8439-73d41ffca540", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "59335f20-1ff3-4163-8844-d0bccb5c1dd8"}}}]}, {"uuid": "0b0521c1-45dd-4a1f-8d44-d93a0eaf0b10", "name": "load_p1rlv170_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f7dbd18-1cbe-49d3-b490-3c46cf8e37f1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c7a14033-b9a3-4231-8824-61308ee49db0"}}}}, {"uuid": "86845da4-bb7d-4900-9c00-c6be83efd8ca", "name": "a6904d60-3eda-4ac0-9945-67a01bc5e6d7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7997673490012955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.772957044307952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f8da8d9c-2705-4d59-9e4a-99d23673be05", "name": "b389c1ff-fe5b-4cb8-8253-5b50ddf92ea7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "86845da4-bb7d-4900-9c00-c6be83efd8ca"}}}]}, {"uuid": "b861f8df-f309-4edb-a49e-5abbc43f7496", "name": "load_p1rlv174_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1186295-59ff-48a8-b31d-0f7cd40df1ab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f8da8d9c-2705-4d59-9e4a-99d23673be05"}}}}, {"uuid": "6cada501-95eb-4758-ae39-fe53048531d5", "name": "27711f95-8460-40c6-9724-4f27c75fc0eb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7997673490012955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.772957044307952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7d080bb8-d0ae-4e18-a50e-af67f4a22adb", "name": "38120dbf-2229-4a03-a721-2a227cae7ab8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6cada501-95eb-4758-ae39-fe53048531d5"}}}]}, {"uuid": "5ef0ca22-9b94-4e1c-87b4-ce7fb335b3f8", "name": "load_p1rlv174_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1186295-59ff-48a8-b31d-0f7cd40df1ab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7d080bb8-d0ae-4e18-a50e-af67f4a22adb"}}}}, {"uuid": "32d09fa6-77c4-4c1b-bb61-807cfc09ff43", "name": "c480aefe-44ba-44d6-9062-01b0ef9fd938_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2562100051220524, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.06533962175647968, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e648a41d-31dd-415d-a78b-6f023dfdd28d", "name": "a2b00fbb-9868-459e-91e2-464d724fbbb0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "32d09fa6-77c4-4c1b-bb61-807cfc09ff43"}}}]}, {"uuid": "13593603-abcb-4843-9994-1637c6b41373", "name": "load_p1rlv175_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905e9287-bdb6-44e0-b0af-f59ab4ad4d8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e648a41d-31dd-415d-a78b-6f023dfdd28d"}}}}, {"uuid": "93daaec5-a80d-4c09-a45c-c9e4efe1553c", "name": "4d0e3ca5-98a1-478f-99f3-4c2abe4fecec_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2562100051220524, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.06533962175647968, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "912c8def-e8ae-4a1e-9ad7-0e603c08a529", "name": "4f5b5bcc-a092-48a9-8a4b-19eb8dbf520b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "93daaec5-a80d-4c09-a45c-c9e4efe1553c"}}}]}, {"uuid": "a64c2d9e-7189-4d59-a635-5f3fea3d070e", "name": "load_p1rlv175_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905e9287-bdb6-44e0-b0af-f59ab4ad4d8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "912c8def-e8ae-4a1e-9ad7-0e603c08a529"}}}}, {"uuid": "698bdf1b-1257-4c31-85f8-bacacde1eb47", "name": "babffe7a-fa6f-40a4-a3d7-450c5fbb1531_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6697995975485909, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.41657408993223344, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "407f8084-cfa0-4adf-afe9-7ad0952ad9a8", "name": "180a6a17-b6a5-4caa-a113-9d8208147f1c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "698bdf1b-1257-4c31-85f8-bacacde1eb47"}}}]}, {"uuid": "9d01e606-f835-479b-b804-4f81eef27ac3", "name": "load_p1rlv176_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "931c8cee-89fe-447d-8788-af1e5f9f8775"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "407f8084-cfa0-4adf-afe9-7ad0952ad9a8"}}}}, {"uuid": "99e5d20b-27ce-4d39-b06a-3c44e17dcda4", "name": "e30615b3-a943-46c8-b4e7-5117468922d2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6697995975485909, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.41657408993223344, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e2b94225-1356-4853-bfa6-176c0a433f9b", "name": "a37c0ac8-c612-4374-9882-9cc962aea7b7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "99e5d20b-27ce-4d39-b06a-3c44e17dcda4"}}}]}, {"uuid": "036940e5-1dde-482f-8a28-985360b13eb8", "name": "load_p1rlv176_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "931c8cee-89fe-447d-8788-af1e5f9f8775"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e2b94225-1356-4853-bfa6-176c0a433f9b"}}}}, {"uuid": "8e2d83b6-5e0f-4403-98cc-978ff787b4ca", "name": "42c249c8-a282-4f34-9fa9-663f5b585402_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4063851199490187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16385595528128288, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "811492a9-f6d4-4b8c-80c0-f863291bfcf7", "name": "e9a6c2c9-1727-417b-9248-d78e56d70a45", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8e2d83b6-5e0f-4403-98cc-978ff787b4ca"}}}]}, {"uuid": "29c19a1f-f23f-4648-97ec-b4c8b61f383f", "name": "load_p1rlv177_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "090d6084-5cc6-473d-99c0-a6309571d633"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "811492a9-f6d4-4b8c-80c0-f863291bfcf7"}}}}, {"uuid": "df803f20-308e-4fe6-844b-d129655543e6", "name": "13f10b9b-e510-446b-a882-74a62ae51dc9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4063851199490187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16385595528128288, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c1b844f0-b3b1-4af5-9201-f97f01504132", "name": "6662538b-8582-480c-b4b6-1ccd18cd440c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "df803f20-308e-4fe6-844b-d129655543e6"}}}]}, {"uuid": "d329efae-e466-4e6b-8fb8-24065f82fa03", "name": "load_p1rlv177_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "090d6084-5cc6-473d-99c0-a6309571d633"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c1b844f0-b3b1-4af5-9201-f97f01504132"}}}}, {"uuid": "29520ab8-c7dd-456f-b4db-2b585ff86051", "name": "9b00560f-85e3-4b99-9b63-bb2a4d907d18_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3919966449037446, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.25526897783955566, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eae97a79-5117-4b6a-9c56-897666501298", "name": "e875f6e1-849f-4df7-bbbb-0b36d4833763", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "29520ab8-c7dd-456f-b4db-2b585ff86051"}}}]}, {"uuid": "44644e90-47ad-4157-a7f5-2dd87e9b3172", "name": "load_p1rlv178_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9debf70-62f4-4870-ad8b-bffc4bc4ad3f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eae97a79-5117-4b6a-9c56-897666501298"}}}}, {"uuid": "0a3b3667-f263-4612-968a-c393477614a0", "name": "8428cf0f-b9e1-4726-a653-40ca39b5e34e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3919966449037446, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.25526897783955566, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0c3ae6b3-dc8d-4283-af06-4e0a124a1079", "name": "d670777d-88ca-4db2-925a-b09d361259bd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0a3b3667-f263-4612-968a-c393477614a0"}}}]}, {"uuid": "d628e1e1-2c23-427b-86a1-8a5297639e27", "name": "load_p1rlv178_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9debf70-62f4-4870-ad8b-bffc4bc4ad3f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0c3ae6b3-dc8d-4283-af06-4e0a124a1079"}}}}, {"uuid": "ea998f67-c04a-4494-98c4-064f1a9f2336", "name": "fa1d8715-c8b9-4f92-9f0d-5f38fd60569d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2601927423507288, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13915962527089715, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "428a7349-08ef-465b-8e74-58ac9d3fe537", "name": "75b7c4a3-cf9d-4665-8a74-5895e7bd2fb6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ea998f67-c04a-4494-98c4-064f1a9f2336"}}}]}, {"uuid": "7a97bfc2-9f49-403d-b794-3f116aba6c9a", "name": "load_p1rlv179_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb03260b-d7d7-4779-ab2c-37c9a1e34d66"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "428a7349-08ef-465b-8e74-58ac9d3fe537"}}}}, {"uuid": "4ad41fa7-5d89-41fa-b3e1-a38addab38d1", "name": "0d7f7e8e-b66a-4544-9ac6-0f8fae22229d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2601927423507288, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13915962527089715, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "58befe5b-f61e-4628-a5d3-a10a18294c9b", "name": "73013f72-7f5e-476f-8c35-1d744b0417ef", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4ad41fa7-5d89-41fa-b3e1-a38addab38d1"}}}]}, {"uuid": "651090f6-dde3-4268-b0f7-9b8f180e98f5", "name": "load_p1rlv179_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb03260b-d7d7-4779-ab2c-37c9a1e34d66"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "58befe5b-f61e-4628-a5d3-a10a18294c9b"}}}}, {"uuid": "ed163f46-f389-484a-94fc-a9b331c41498", "name": "a216477c-85cb-41c9-82fb-76a01c8fefea_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2659851154673674, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7880475847724098, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "842b74ac-4c55-4a3a-ab3f-7c4334c352ef", "name": "601af922-d980-495a-8064-27c3cdb0b3bd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ed163f46-f389-484a-94fc-a9b331c41498"}}}]}, {"uuid": "45f3055c-726c-485c-bdd8-1117acdc412a", "name": "load_p1rlv285_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d3a86df-2ac5-4959-b857-562795ce84ba"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "842b74ac-4c55-4a3a-ab3f-7c4334c352ef"}}}}, {"uuid": "c8ac35f5-ff97-4160-9768-d475b43c0558", "name": "b3738bf2-a2c6-46f6-8e66-384b2579bf42_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2659851154673674, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7880475847724098, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a258932-2782-467b-b763-1a702c820449", "name": "a51f40ca-ad49-4ccd-b8ac-c34e8ab16026", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c8ac35f5-ff97-4160-9768-d475b43c0558"}}}]}, {"uuid": "6479420b-32b6-41c7-a90d-68d7d778a703", "name": "load_p1rlv285_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d3a86df-2ac5-4959-b857-562795ce84ba"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0a258932-2782-467b-b763-1a702c820449"}}}}, {"uuid": "1c177bae-3836-497a-9053-d4ead03fbd3c", "name": "e3d417f2-bf21-4f7c-8f2f-5987506a39da_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7aa7dc8d-fb03-4602-a9c7-2c8a3f57e11e", "name": "fe88390d-2742-4c94-9aac-b19ed839235a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1c177bae-3836-497a-9053-d4ead03fbd3c"}}}]}, {"uuid": "4556cea0-a96e-4e33-89b2-36d259fbf452", "name": "load_p1rlv337_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57b88281-b728-4779-82b1-4cc9eb4b41b1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7aa7dc8d-fb03-4602-a9c7-2c8a3f57e11e"}}}}, {"uuid": "f1501d64-73bc-43d1-b883-0c114a180b3f", "name": "b1dd7efd-f593-4adc-8da9-7256bd29e94f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "472244fd-1054-4fbf-a42e-caac2dc2776d", "name": "41ced716-013c-4d5c-a7ed-ff05a893b220", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f1501d64-73bc-43d1-b883-0c114a180b3f"}}}]}, {"uuid": "9ea99031-1a73-4860-8941-03176411c5bf", "name": "load_p1rlv337_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57b88281-b728-4779-82b1-4cc9eb4b41b1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "472244fd-1054-4fbf-a42e-caac2dc2776d"}}}}, {"uuid": "d204acfa-ed37-4a6b-95eb-8de35bfabbc1", "name": "515ac681-bc87-4785-98b5-8f8a94c86b73_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2045141672666357, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3046267940472902, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7289962d-1ada-451f-b2c9-e221764be8f2", "name": "21c661fe-a346-4b28-aa4e-23df3068ca6c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d204acfa-ed37-4a6b-95eb-8de35bfabbc1"}}}]}, {"uuid": "6cbf86aa-64e8-43d6-a2b2-92c2c3acfb3f", "name": "load_p1rlv338_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6b2aba6-a289-4a50-a131-2064047d1341"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7289962d-1ada-451f-b2c9-e221764be8f2"}}}}, {"uuid": "42fbd9cf-1d1c-4abc-85bd-116b6ddf9bfa", "name": "14038502-db61-4a46-b69e-1c39f41d22a3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2045141672666357, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3046267940472902, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1ee17721-78a2-48e2-b84d-63ff7d2774e2", "name": "854c52d5-f691-4c09-b7aa-2defe0872bad", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "42fbd9cf-1d1c-4abc-85bd-116b6ddf9bfa"}}}]}, {"uuid": "c5486f4c-d67c-491a-a3b9-721e60f5bfe3", "name": "load_p1rlv338_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6b2aba6-a289-4a50-a131-2064047d1341"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1ee17721-78a2-48e2-b84d-63ff7d2774e2"}}}}, {"uuid": "6439cd2a-e885-4ff0-886a-36d603472278", "name": "6809aa00-7d60-4f12-bccd-5637e38d38b4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.749950841708346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2019248045205122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "05626810-c934-47c1-9b5e-0be633089952", "name": "9e0a0824-5fa4-4caa-a072-29dd33106920", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6439cd2a-e885-4ff0-886a-36d603472278"}}}]}, {"uuid": "3923f8d0-d62f-4abe-a647-2a3892b503e7", "name": "load_p1rlv340_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb4797d6-b46e-4058-8985-d9f4b660f0a7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "05626810-c934-47c1-9b5e-0be633089952"}}}}, {"uuid": "6c6c9a34-29b0-4314-9fe4-d2c4c3852ee8", "name": "96a9059b-9ada-4807-a11d-56012857b21e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.749950841708346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2019248045205122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6e25347e-dd30-4db8-99fb-a71a4a549692", "name": "ab84c3c8-001a-4eb0-8134-2b8035150c17", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c6c9a34-29b0-4314-9fe4-d2c4c3852ee8"}}}]}, {"uuid": "eb14f439-9aa1-4079-96fe-45e6e5847e93", "name": "load_p1rlv340_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb4797d6-b46e-4058-8985-d9f4b660f0a7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6e25347e-dd30-4db8-99fb-a71a4a549692"}}}}, {"uuid": "ab205c2d-87ef-4ce5-90dc-e70ae13d27f4", "name": "2005a09f-d78d-4c2c-8b43-2a9aba13acc5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7771517670040275, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8838563298920215, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e6a4afe8-741d-460d-9bcc-f3f77a31cc45", "name": "09c46746-251c-4784-8f41-c60a076be7f3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ab205c2d-87ef-4ce5-90dc-e70ae13d27f4"}}}]}, {"uuid": "561c4565-dc97-4f33-8ad7-42971c29c365", "name": "load_p1rlv341_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54f0ea2c-3849-4ff0-ad8c-e3f65515d178"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e6a4afe8-741d-460d-9bcc-f3f77a31cc45"}}}}, {"uuid": "fbebc68b-d886-4b60-bf1b-7197de9935e5", "name": "d6adca28-a492-4e3b-88dd-c246096a3336_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7771517670040275, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8838563298920215, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "191609e9-fb6c-46b6-95dd-29c9168574f4", "name": "156033c8-3e75-405d-af6e-0eb9dc3de4fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fbebc68b-d886-4b60-bf1b-7197de9935e5"}}}]}, {"uuid": "afcd055b-9509-4910-b384-8233cc9e4e6b", "name": "load_p1rlv341_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54f0ea2c-3849-4ff0-ad8c-e3f65515d178"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "191609e9-fb6c-46b6-95dd-29c9168574f4"}}}}, {"uuid": "f63cca78-c62d-445c-8a2e-215e0eab54d9", "name": "b7983a4b-95a0-45fe-b036-0f5c851a90fa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.4540014644243024, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4055170204295049, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82e02e2e-8676-4814-862e-8c81992484b3", "name": "914f473c-173c-49fd-8ea2-c63522e0a60e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f63cca78-c62d-445c-8a2e-215e0eab54d9"}}}]}, {"uuid": "a78c25f5-e873-4dd8-b731-2c3ff4901b82", "name": "load_p1rlv342_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13754fdb-4039-49fb-b584-8437191dfb2b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "82e02e2e-8676-4814-862e-8c81992484b3"}}}}, {"uuid": "3acb654a-aa3c-4022-915f-e73e57b302cd", "name": "241003e9-2fef-4a7f-9350-0e620c9a620c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.4540014644243024, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4055170204295049, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3b3af3e2-a813-4fdc-9902-68f5e308c8d5", "name": "9f040f50-6d2d-4f18-bc6f-2ab763c4f055", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3acb654a-aa3c-4022-915f-e73e57b302cd"}}}]}, {"uuid": "29b09a02-af7d-4f10-a1a5-5b3bb8ac37a8", "name": "load_p1rlv342_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13754fdb-4039-49fb-b584-8437191dfb2b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3b3af3e2-a813-4fdc-9902-68f5e308c8d5"}}}}, {"uuid": "46d2407f-a957-4126-a965-30b5fbbce9d9", "name": "48f60e72-1afb-466c-9907-47aa705e05f0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.13715702476687, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3795210711832634, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "780f8a0e-2872-4cd4-9a86-380a9be5d8a3", "name": "45b5032e-3500-4368-8510-e49470dc54fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "46d2407f-a957-4126-a965-30b5fbbce9d9"}}}]}, {"uuid": "7ca6a310-ece1-4515-b89c-91799dfde079", "name": "load_p1rlv343_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0197ef22-9f8f-48a9-84de-663a7ce22773"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "780f8a0e-2872-4cd4-9a86-380a9be5d8a3"}}}}, {"uuid": "31aaa454-e1df-4166-aa08-efef0b899f81", "name": "3e9d777a-3af9-40a3-b89f-aaa24aa1797e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.13715702476687, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3795210711832634, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cbe8525b-a364-4c00-bada-3cb6d22575fa", "name": "85dab30e-30a4-423c-b797-cd08b694cbdd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "31aaa454-e1df-4166-aa08-efef0b899f81"}}}]}, {"uuid": "1404590a-7410-49e3-a904-b7e2f385f6a7", "name": "load_p1rlv343_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0197ef22-9f8f-48a9-84de-663a7ce22773"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cbe8525b-a364-4c00-bada-3cb6d22575fa"}}}}, {"uuid": "004d9144-06c7-40fa-a842-d07cf3457dac", "name": "98219f76-b003-414b-a065-9d41a2cd7b67_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.2930994643856595, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9073205938076818, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a757014b-52d3-40d4-849a-0de412ddaca2", "name": "ffe8f721-ff1c-41e6-adeb-b778f310e837", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "004d9144-06c7-40fa-a842-d07cf3457dac"}}}]}, {"uuid": "f8c96c76-4500-4902-be1e-8995417b8744", "name": "load_p1rlv377_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e1ea241-5329-4db5-996a-df09a9c25687"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a757014b-52d3-40d4-849a-0de412ddaca2"}}}}, {"uuid": "0dcf4eab-54e8-4541-8890-27e214ff59b7", "name": "a5c27446-e8c1-4d61-bfbd-9c778dabe13c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.2930994643856595, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9073205938076818, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "427eb9c6-1136-418d-abde-61d3a2b4041d", "name": "5432649f-73cd-4435-a788-f7d1b72d0967", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0dcf4eab-54e8-4541-8890-27e214ff59b7"}}}]}, {"uuid": "5ad57ec9-af8b-4b00-a356-ecf78415ae20", "name": "load_p1rlv377_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e1ea241-5329-4db5-996a-df09a9c25687"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "427eb9c6-1136-418d-abde-61d3a2b4041d"}}}}, {"uuid": "94c37143-9b5c-474e-99b2-b002ffbfccb4", "name": "3a44a044-db43-48e8-a935-f5e04bd91034_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.651809392632849, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.766759151751063, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "97f2d645-e451-42da-aece-d78a6970ecfc", "name": "a92532cc-0b0b-49f2-ae7c-ea34320889c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "94c37143-9b5c-474e-99b2-b002ffbfccb4"}}}]}, {"uuid": "d80a4f02-d2e1-4f5a-80e8-45a4378ac616", "name": "load_p1rlv378_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3ff63a0-bf3f-43b0-807c-935467b4fe46"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "97f2d645-e451-42da-aece-d78a6970ecfc"}}}}, {"uuid": "0e323603-a17e-407b-83af-62febe03a71c", "name": "ecaa4e08-c740-4566-8601-9a1491659c6e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.651809392632849, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.766759151751063, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "60f67866-5481-4e96-8dd8-0240b485e74e", "name": "76c22656-994c-4b14-9c13-7b9f159d03dc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0e323603-a17e-407b-83af-62febe03a71c"}}}]}, {"uuid": "8d2908f9-6481-4036-9550-bc9b126c0e7a", "name": "load_p1rlv378_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3ff63a0-bf3f-43b0-807c-935467b4fe46"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "60f67866-5481-4e96-8dd8-0240b485e74e"}}}}, {"uuid": "290ee85f-789b-4ced-8dea-094061874c37", "name": "de0a417d-6eae-4df1-9d8e-97a3d259a85c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.096838644473719, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3876192860701033, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6e4cac71-6f88-414e-9062-1212fb7c57de", "name": "d818b75f-425c-4d11-992e-fbae2b838669", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "290ee85f-789b-4ced-8dea-094061874c37"}}}]}, {"uuid": "73f6f7ba-a150-4170-96bf-a852b546e239", "name": "load_p1rlv379_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50225dcf-40bc-44b5-9dec-072ac5b2334e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6e4cac71-6f88-414e-9062-1212fb7c57de"}}}}, {"uuid": "117a6938-112f-45c1-8ae5-c713f9d0a91b", "name": "d1460c02-979f-46df-9f4e-92cd244a3564_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.096838644473719, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3876192860701033, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9f33b4de-345c-4f35-8e17-a9a339cf2869", "name": "022bd3c9-10ad-44f1-b125-18dea4f660f5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "117a6938-112f-45c1-8ae5-c713f9d0a91b"}}}]}, {"uuid": "34220f1f-be21-4cc4-8bb4-4b7eade70fcb", "name": "load_p1rlv379_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50225dcf-40bc-44b5-9dec-072ac5b2334e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9f33b4de-345c-4f35-8e17-a9a339cf2869"}}}}, {"uuid": "b0b45149-b134-4171-b53b-6dd758d0a7a4", "name": "0010f4b1-dc0e-4d20-b884-f9e6ec67d62e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5996895391512607, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5332968923160806, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "24a9217d-fe72-4420-8696-febd57d3910f", "name": "834f12fe-e7fb-4be2-924c-e758065cedb2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b0b45149-b134-4171-b53b-6dd758d0a7a4"}}}]}, {"uuid": "f534baff-d593-496b-b97d-4d6125708942", "name": "load_p1rlv380_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ee07ef9-b7b0-4457-be1c-78e754dbcfc7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "24a9217d-fe72-4420-8696-febd57d3910f"}}}}, {"uuid": "13a657a3-c0e6-4664-bbdf-f01b5a50223b", "name": "cd7ba6a9-1d52-499b-9fde-a6e4f4375cb7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5996895391512607, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5332968923160806, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fb8d2ec8-db5f-492e-8273-caea9dfba693", "name": "4c6be107-899d-468e-b909-872fd2bdd8a9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "13a657a3-c0e6-4664-bbdf-f01b5a50223b"}}}]}, {"uuid": "75ccf78c-c765-41a6-bb56-37de514dfd86", "name": "load_p1rlv380_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ee07ef9-b7b0-4457-be1c-78e754dbcfc7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fb8d2ec8-db5f-492e-8273-caea9dfba693"}}}}, {"uuid": "9edb37d5-caa0-4b00-9a26-a1aef7b642d2", "name": "2f2f95a1-ff09-4219-9373-12da064989c4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2825930802168721, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5903675615779559, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9f696408-f8d5-435c-b48a-a1b120d685f5", "name": "f3de3b82-5836-4416-aeac-2bd18e3337a2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9edb37d5-caa0-4b00-9a26-a1aef7b642d2"}}}]}, {"uuid": "1201db9d-fab3-415c-8e76-196f246cee65", "name": "load_p1rlv412_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b33ed36-116b-4741-9374-6927bd537427"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9f696408-f8d5-435c-b48a-a1b120d685f5"}}}}, {"uuid": "73ab955f-6770-4bd4-8b30-d11d86f9c7e3", "name": "f5f99842-6cc1-45f2-9739-1134e07d34ec_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2825930802168721, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5903675615779559, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fd4a14f5-a2b4-4f81-821c-6ddbe1b5a91a", "name": "ec891b7a-d6d3-4735-8205-10cb67fdb0b6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "73ab955f-6770-4bd4-8b30-d11d86f9c7e3"}}}]}, {"uuid": "1b537d77-e45c-4ae0-8dea-bc86cdd481b6", "name": "load_p1rlv412_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b33ed36-116b-4741-9374-6927bd537427"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fd4a14f5-a2b4-4f81-821c-6ddbe1b5a91a"}}}}, {"uuid": "84949f0b-d44d-4a0a-9a39-3365a68a2314", "name": "b66335e1-8e77-471c-a647-d252b422f28a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5218330234822437, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6111559757217505, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "956c3863-e83f-4114-89f4-119b9934a4bc", "name": "f20afc4a-dda8-4342-a86a-736bfec026d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "84949f0b-d44d-4a0a-9a39-3365a68a2314"}}}]}, {"uuid": "257f2e68-1456-4e2f-8fe7-fe6c17012ce3", "name": "load_p1rlv413_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8408ac87-a086-46bc-9d88-cca79e17dd62"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "956c3863-e83f-4114-89f4-119b9934a4bc"}}}}, {"uuid": "b2175bbc-4c32-40bb-9689-315b3bcc6d77", "name": "4d03acdd-3b5a-4a2f-9bde-c864876ffc0f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5218330234822437, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6111559757217505, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5607d053-3b06-4109-a565-cfa46dd43ff6", "name": "114afa60-6b70-4d0d-88be-b71871e0249b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b2175bbc-4c32-40bb-9689-315b3bcc6d77"}}}]}, {"uuid": "3cd0305c-20bb-422f-ade5-5c72aa5bf079", "name": "load_p1rlv413_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8408ac87-a086-46bc-9d88-cca79e17dd62"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5607d053-3b06-4109-a565-cfa46dd43ff6"}}}}, {"uuid": "25658ac8-9f93-4d5c-92bd-34dd271c0f9e", "name": "668f02ae-de18-4809-9dd7-a058c84d5985_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.307247144150686, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17783357819798717, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a7fe75cd-0f4b-4b3c-ae8b-71f0919b3f14", "name": "fb1e58e1-f7b4-4623-8ba6-1d4e7529a98e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "25658ac8-9f93-4d5c-92bd-34dd271c0f9e"}}}]}, {"uuid": "35b4e3bb-abfb-4915-bf67-85f1523b4a79", "name": "load_p1rlv414_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec2c1edd-78b1-4436-85cc-2fbc7d880b87"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a7fe75cd-0f4b-4b3c-ae8b-71f0919b3f14"}}}}, {"uuid": "b0150c1f-3a29-4ff7-826e-65ce32bf3402", "name": "3eb4c88f-abac-453f-9d93-39ef129a1d8f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.307247144150686, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17783357819798717, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ff753503-a4c9-4e5b-a4dd-6695e34a72cf", "name": "30305ae5-0ba2-41ba-8318-c583c284b3b7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b0150c1f-3a29-4ff7-826e-65ce32bf3402"}}}]}, {"uuid": "4bdf7a06-175a-4680-9f3f-f675b8c9e04b", "name": "load_p1rlv414_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec2c1edd-78b1-4436-85cc-2fbc7d880b87"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ff753503-a4c9-4e5b-a4dd-6695e34a72cf"}}}}, {"uuid": "5a4ad912-137b-4edb-80e4-bdf9777227e0", "name": "b5e7052a-bbd0-4b2c-ab85-b69824d5cd68_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5478654763148745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5646840796232575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2d39b745-c630-47ab-9da9-88d2b940963e", "name": "100b605b-2a00-4b97-9ec6-48a6ccc8f450", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5a4ad912-137b-4edb-80e4-bdf9777227e0"}}}]}, {"uuid": "a9fd2337-e212-4577-b3e0-d54b489d242f", "name": "load_p1rlv415_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b54aae8-5a94-4e04-882f-748e1c5f1390"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2d39b745-c630-47ab-9da9-88d2b940963e"}}}}, {"uuid": "9752f792-cdad-4a22-8069-f260252ead54", "name": "79c4a47c-32a3-4c67-9a2b-803120fdff31_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5478654763148745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5646840796232575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5bb18331-14c7-4223-b4e8-25be9b609caa", "name": "46a57404-cee0-492b-84c7-8022e3de81fc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9752f792-cdad-4a22-8069-f260252ead54"}}}]}, {"uuid": "544ef15a-50b6-4c3e-bcfb-05594c086a25", "name": "load_p1rlv415_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b54aae8-5a94-4e04-882f-748e1c5f1390"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5bb18331-14c7-4223-b4e8-25be9b609caa"}}}}, {"uuid": "236f88fc-0b20-4017-9d1f-675e72532aa8", "name": "5d27f300-a078-47fe-8758-e12c363092a5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2437699409140923, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5571842941855458, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fe160672-65f9-422a-9671-4bdc27a622cb", "name": "f786ba5b-b576-41c9-b08d-f961568173e3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "236f88fc-0b20-4017-9d1f-675e72532aa8"}}}]}, {"uuid": "4ff614f9-c0c4-40d4-bfa4-88e78ed45956", "name": "load_p1rlv416_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99abc7dc-8e15-420f-9bc9-0e6229d4dab3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fe160672-65f9-422a-9671-4bdc27a622cb"}}}}, {"uuid": "8aed49d1-541b-4b5c-9f2e-3c5cff27502e", "name": "1e7379ad-fa51-40c3-90eb-d3c5e01261aa_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2437699409140923, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5571842941855458, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1d2b8e34-0dc2-4c63-81ad-6d79487b2e54", "name": "40629f65-fa44-4e45-a92a-3643edc7dc74", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8aed49d1-541b-4b5c-9f2e-3c5cff27502e"}}}]}, {"uuid": "82c78be7-41d1-4915-8907-9969c6287ce0", "name": "load_p1rlv416_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99abc7dc-8e15-420f-9bc9-0e6229d4dab3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1d2b8e34-0dc2-4c63-81ad-6d79487b2e54"}}}}, {"uuid": "55122e3e-f38d-4d1b-86da-c7401f27692e", "name": "fcbad943-9a9c-47ee-a121-c4676330ce18_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1698158732703443, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8490689598373361, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ef1bdc26-4c6e-4e24-8d2f-6bb4f0406a79", "name": "2f060849-2e72-4eea-b384-048580d8e5fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "55122e3e-f38d-4d1b-86da-c7401f27692e"}}}]}, {"uuid": "cd8c15e0-e322-449b-bce6-7a643e578731", "name": "load_p1rlv417_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49dbdd44-a36a-46b5-aef8-558ef7693315"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ef1bdc26-4c6e-4e24-8d2f-6bb4f0406a79"}}}}, {"uuid": "74a63396-c2b6-4f4b-af3f-43efe8e564a9", "name": "c7df32c2-cdf3-45b5-90fc-57e75e7e30b1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1698158732703443, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8490689598373361, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "49b098d1-e734-47b1-a9da-6c4a48a0520a", "name": "30e3bf61-f498-4702-81ef-3a75714458e8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "74a63396-c2b6-4f4b-af3f-43efe8e564a9"}}}]}, {"uuid": "f8e88484-6c6e-45e3-a52a-e736bf05bff7", "name": "load_p1rlv417_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49dbdd44-a36a-46b5-aef8-558ef7693315"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "49b098d1-e734-47b1-a9da-6c4a48a0520a"}}}}, {"uuid": "ab938fa9-a68b-400e-a8e7-d64902836b00", "name": "32268d5a-2da6-4aa3-b876-ced5699e0813_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "58a9e0b3-d78c-4ac9-9604-2a109b6f58a4", "name": "b375611a-bb86-4e95-801c-434f495d8c60", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ab938fa9-a68b-400e-a8e7-d64902836b00"}}}]}, {"uuid": "e39d1d14-3bf8-4464-ae5e-e71464d9438f", "name": "load_p1rlv418_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b54aae8-5a94-4e04-882f-748e1c5f1390"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "58a9e0b3-d78c-4ac9-9604-2a109b6f58a4"}}}}, {"uuid": "1f37b3c6-3ecf-43ad-9e38-3a3dc3a0cc26", "name": "6f014ce4-d03c-4b4e-945a-3d1eba73bdec_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "63163c6c-7cba-4439-850c-9084634f2124", "name": "f4ba3843-c683-4ff0-92b9-ef860b481e32", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1f37b3c6-3ecf-43ad-9e38-3a3dc3a0cc26"}}}]}, {"uuid": "f244f5bf-9001-4806-a729-a2167668ce93", "name": "load_p1rlv418_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b54aae8-5a94-4e04-882f-748e1c5f1390"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "63163c6c-7cba-4439-850c-9084634f2124"}}}}, {"uuid": "55a6f0de-1376-4b1c-b506-a6f1d294f948", "name": "0165d7b3-8b43-47c0-8136-0fbfff30a059_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7500687162104853, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7707974088873139, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b043d947-32fc-4198-b244-45fc8c302d0a", "name": "bf1977d4-2132-4dfc-97c4-179e2d725e4a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "55a6f0de-1376-4b1c-b506-a6f1d294f948"}}}]}, {"uuid": "d8182e93-d5f4-4313-ade2-e469a3bb5d8c", "name": "load_p1rlv419_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7935b9c-b631-432c-a322-9beea73f1fc4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b043d947-32fc-4198-b244-45fc8c302d0a"}}}}, {"uuid": "dd9ae778-2841-4cae-80ae-503efc54ca9c", "name": "6f2adaac-f7b6-408c-9907-ab7bc43f7bee_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7500687162104853, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7707974088873139, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2c97cf19-a37a-4490-bae2-368b37e51bca", "name": "7962d5af-9a27-4c06-9a06-c5c13eb29a5b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dd9ae778-2841-4cae-80ae-503efc54ca9c"}}}]}, {"uuid": "6fba622d-d85c-4cfa-b494-58951b880d4e", "name": "load_p1rlv419_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7935b9c-b631-432c-a322-9beea73f1fc4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2c97cf19-a37a-4490-bae2-368b37e51bca"}}}}, {"uuid": "2a3896a4-969d-48ca-baab-71091982350d", "name": "3cff9dd6-70ac-4346-b7e0-30d7b4c5b2cf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6434260893942235, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2588956175598443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6447e97c-5dd4-4d30-a85b-0bc2e08e72db", "name": "5995a59c-f31e-42b9-b7b1-7f975115716b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2a3896a4-969d-48ca-baab-71091982350d"}}}]}, {"uuid": "0aa79a4c-aea1-4025-9923-8593ea232b24", "name": "load_p1rlv420_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4d7ed8-5ddd-4127-87ab-eb3f48a580c2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6447e97c-5dd4-4d30-a85b-0bc2e08e72db"}}}}, {"uuid": "cdec3867-35e4-4fb8-8021-a976b3d2b085", "name": "9cd4ca9f-c37d-4ab7-9917-3d19039f140a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6434260893942235, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2588956175598443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "25b0c049-def9-4072-b041-5bf6ee171db9", "name": "d0b9cd2b-09f6-49ae-aa4e-88d98a0ebd82", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cdec3867-35e4-4fb8-8021-a976b3d2b085"}}}]}, {"uuid": "94167872-f880-4f9c-af3a-1e15003d571b", "name": "load_p1rlv420_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4d7ed8-5ddd-4127-87ab-eb3f48a580c2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "25b0c049-def9-4072-b041-5bf6ee171db9"}}}}, {"uuid": "3c53efed-5f98-4e1d-9121-1df30d025cc9", "name": "62b17c48-45de-45fd-9566-27fe55bf2649_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6669289783709, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.056901546523703654, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "996a80b3-261b-43a1-91c5-21c792a73994", "name": "8b92c237-c090-4e84-b560-99c2e5c9ae24", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3c53efed-5f98-4e1d-9121-1df30d025cc9"}}}]}, {"uuid": "563cc9c0-de0d-400a-8f79-e346ad461693", "name": "load_p1rlv421_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12dcb168-1bfe-448b-8d9a-f5cb4c61aafe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "996a80b3-261b-43a1-91c5-21c792a73994"}}}}, {"uuid": "7de77097-4a79-4bfe-b65e-29cbf44811c2", "name": "6e0fe43e-b16c-4f7e-9349-d521a6f60151_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6669289783709, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.056901546523703654, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0fde27dd-70e3-42a9-b281-117a5b6ded40", "name": "9d4161dc-d429-4582-96aa-69a6db295ab8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7de77097-4a79-4bfe-b65e-29cbf44811c2"}}}]}, {"uuid": "c797796a-12c9-439b-903d-d720319a9f5d", "name": "load_p1rlv421_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12dcb168-1bfe-448b-8d9a-f5cb4c61aafe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0fde27dd-70e3-42a9-b281-117a5b6ded40"}}}}, {"uuid": "05991d9c-522e-4349-a36c-fd44e2dd07f1", "name": "324242e3-d208-4a59-9931-b871fa753018_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.933146793098512, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9686684100837105, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9cfd504c-4877-491c-912c-fbe81dace76d", "name": "1c7d4e5f-3295-40b5-81f0-0c4074306a7c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "05991d9c-522e-4349-a36c-fd44e2dd07f1"}}}]}, {"uuid": "ff597d6c-e00d-46a3-ba9b-b0e0829959ac", "name": "load_p1rlv422_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa7bb51b-8ba8-4a05-872a-7f5ce084fe88"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9cfd504c-4877-491c-912c-fbe81dace76d"}}}}, {"uuid": "c10cf9cb-91fc-4e09-8683-2c939cc3a0bb", "name": "da66753e-185f-4c0c-a216-68566b61192d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.933146793098512, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9686684100837105, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4d9d9d46-178a-427d-9a33-efb4da3cefdc", "name": "cd2b9061-a50c-466b-be80-2aefbd0c6ce2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c10cf9cb-91fc-4e09-8683-2c939cc3a0bb"}}}]}, {"uuid": "2b22dc58-7860-4849-a2c5-d982f61301e8", "name": "load_p1rlv422_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa7bb51b-8ba8-4a05-872a-7f5ce084fe88"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4d9d9d46-178a-427d-9a33-efb4da3cefdc"}}}}, {"uuid": "33520d61-57c6-4233-8f24-2ca00485cd8f", "name": "b29beaa2-d8b8-47b8-abe4-d78d560ae6a2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0491915565570302, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1506537762556939, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "94a80965-d56a-49e4-99d1-7130b1ec198b", "name": "74a55b1d-5afa-4d60-9810-cb3ec599c176", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "33520d61-57c6-4233-8f24-2ca00485cd8f"}}}]}, {"uuid": "bfa11df5-c4a4-4ab5-9b53-898280a44040", "name": "load_p1rlv423_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c1e9680-f7de-497c-953a-54f4db2899e2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "94a80965-d56a-49e4-99d1-7130b1ec198b"}}}}, {"uuid": "a118a7a2-88e6-42c5-89d9-6b41a6ab039e", "name": "e3e4422d-36a0-4d91-a6e5-924efb122083_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0491915565570302, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1506537762556939, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3182748a-a6d3-48e9-941a-e62456a53155", "name": "98a6588c-0e54-4694-a589-f9f6c573c398", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a118a7a2-88e6-42c5-89d9-6b41a6ab039e"}}}]}, {"uuid": "ccf1c0f6-b41e-4007-9928-38c149b8bd6e", "name": "load_p1rlv423_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c1e9680-f7de-497c-953a-54f4db2899e2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3182748a-a6d3-48e9-941a-e62456a53155"}}}}, {"uuid": "4b837012-2e6a-4090-970b-750f34a1077a", "name": "510ecdc7-345f-4f8a-ac44-5323ed39c728_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.048430097374791, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0714377119995753, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bca6a3d7-d6ea-448c-870e-e5499cb6e352", "name": "cc5170e1-d5c0-4e1e-bcdf-4f86e9f197ee", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4b837012-2e6a-4090-970b-750f34a1077a"}}}]}, {"uuid": "00ca86be-72b4-4af6-9b27-7d5bd262f58b", "name": "load_p1rlv424_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1a91c8c-aabd-4fad-8306-908f186a5744"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bca6a3d7-d6ea-448c-870e-e5499cb6e352"}}}}, {"uuid": "5ee2aac4-fd28-492c-9fbf-e14dcfeb1f56", "name": "565efea5-5d16-4069-b9fe-e78a3eb0aedd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.048430097374791, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0714377119995753, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8491090d-1a03-4ae5-bc2b-f1030da5f1f0", "name": "eb6eef64-a023-4f01-8fcf-4239d57adb32", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5ee2aac4-fd28-492c-9fbf-e14dcfeb1f56"}}}]}, {"uuid": "3d6b51d0-c70c-4997-b523-7e7d83ed4353", "name": "load_p1rlv424_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1a91c8c-aabd-4fad-8306-908f186a5744"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8491090d-1a03-4ae5-bc2b-f1030da5f1f0"}}}}, {"uuid": "4c4d408d-bb5c-4094-8251-2bc68ca55034", "name": "310a4edf-3ccc-42ce-a1a4-b52e410a0b85_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8920557288657344, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21990443750848332, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "65ef3c3d-4484-4297-aba5-6eab04605e0f", "name": "24317571-168d-4b75-88d9-4f43c51bc8cf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4c4d408d-bb5c-4094-8251-2bc68ca55034"}}}]}, {"uuid": "d306d9a0-8ad6-4e4a-9f58-981adc0e3883", "name": "load_p1rlv439_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f771660-4dad-43df-b38b-7da5f6180a25"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "65ef3c3d-4484-4297-aba5-6eab04605e0f"}}}}, {"uuid": "3ce337f3-148a-4e7d-9b88-c7750feec37b", "name": "c3a89a09-dc57-4336-ab2b-cad574ec511b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8920557288657344, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21990443750848332, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7c5b24e7-f210-4a14-978c-d3f2bb483082", "name": "2587354e-c5c0-4ba2-ac28-50bec7d9a608", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3ce337f3-148a-4e7d-9b88-c7750feec37b"}}}]}, {"uuid": "256a6866-9c80-4f16-82fd-de7eaae686d7", "name": "load_p1rlv439_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f771660-4dad-43df-b38b-7da5f6180a25"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7c5b24e7-f210-4a14-978c-d3f2bb483082"}}}}, {"uuid": "5261793a-bf29-4c04-8a01-f2d88cc6722d", "name": "2df4b933-77e6-4412-9d27-90b3200a8993_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 16.24059147715281, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.317949795825311, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c4b10fa3-3e22-4c45-9915-cdb65b4cd420", "name": "2df4b933-77e6-4412-9d27-90b3200a8993_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 16.24059147715281, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.317949795825311, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bef03be8-2fa9-4053-97dd-093966a78bee", "name": "2df4b933-77e6-4412-9d27-90b3200a8993_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 16.24059147715281, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.317949795825311, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0bce5227-fc0c-42c0-a499-e53e72b093b7", "name": "58ae15dd-8489-4925-9705-4352ad3f5f7c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5261793a-bf29-4c04-8a01-f2d88cc6722d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c4b10fa3-3e22-4c45-9915-cdb65b4cd420"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bef03be8-2fa9-4053-97dd-093966a78bee"}}}]}, {"uuid": "b1e406c4-63ea-4a23-9d16-363dd259c73b", "name": "load_p1rlv440", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a23f97bc-e7ef-4f64-9e64-314f4a4e17d8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0bce5227-fc0c-42c0-a499-e53e72b093b7"}}}}, {"uuid": "9894d818-8308-4bbc-9f1e-d9074e63f268", "name": "4ad605bf-5a6e-4a72-9956-2536b0fc3b8a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4856814769108864, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8267323554826451, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c542f525-2856-42c6-9de3-5a1f4448113a", "name": "c9021d60-4ed5-4971-adc8-a100beff3342", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9894d818-8308-4bbc-9f1e-d9074e63f268"}}}]}, {"uuid": "5634e75d-43ab-46fd-a2f7-8f7fd2130563", "name": "load_p1rlv441_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a778b00-482c-4b81-8213-f17202a105fa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c542f525-2856-42c6-9de3-5a1f4448113a"}}}}, {"uuid": "25db585c-f02f-4651-9b6a-4fde07288939", "name": "9e1ec08a-7e98-41f3-aec3-501011911653_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4856814769108864, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8267323554826451, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "308df291-ae5e-463c-b62e-5f1df7e8c52f", "name": "a53be65f-b7dc-44ce-bc4c-8cf2befe86cf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "25db585c-f02f-4651-9b6a-4fde07288939"}}}]}, {"uuid": "67265199-e9b6-4225-bd80-a5303316a244", "name": "load_p1rlv441_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a778b00-482c-4b81-8213-f17202a105fa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "308df291-ae5e-463c-b62e-5f1df7e8c52f"}}}}, {"uuid": "9487f595-09d1-4a90-beeb-96cd696e5b1d", "name": "6a0a6019-6ae9-4cb3-8832-1f1ae030f058_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.930214175792893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.08514782397789, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "453f8cfc-b505-47b5-a735-bd50a661eff3", "name": "a2903bfb-4002-4629-aa28-100a4ac73fbf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9487f595-09d1-4a90-beeb-96cd696e5b1d"}}}]}, {"uuid": "6d52ad2a-64bf-47cf-8206-746d44da5175", "name": "load_p1rlv442_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cd667a9-c0ef-49ce-b6ee-7e474d9ae761"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "453f8cfc-b505-47b5-a735-bd50a661eff3"}}}}, {"uuid": "216ec404-c4bd-4582-a482-e9adf27caac9", "name": "b58ba976-9653-4229-9372-2c11f1567a42_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.930214175792893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.08514782397789, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2fce8bd0-bd8d-47c6-a08f-db1e08281e9a", "name": "3de521c0-c2e3-4a13-b814-a09c6af31021", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "216ec404-c4bd-4582-a482-e9adf27caac9"}}}]}, {"uuid": "57e4bfe6-8249-482d-9a03-7ad1b74d4c0a", "name": "load_p1rlv442_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cd667a9-c0ef-49ce-b6ee-7e474d9ae761"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2fce8bd0-bd8d-47c6-a08f-db1e08281e9a"}}}}, {"uuid": "9d74f642-1a58-435c-9922-c95f0a9d371a", "name": "ef632798-1b8c-46da-93d8-b0772f08d5f5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7859412473782077, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.762455747973555, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a79978f4-da2d-4611-9e3e-c29a191a7c4c", "name": "0406b84e-e9a4-4851-a993-006de690057e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9d74f642-1a58-435c-9922-c95f0a9d371a"}}}]}, {"uuid": "55cacdf5-2f34-4f91-a63c-67bda85ddefd", "name": "load_p1rlv443_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2100c17-c0e6-47e9-87f8-72016b22dd4b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a79978f4-da2d-4611-9e3e-c29a191a7c4c"}}}}, {"uuid": "b92e692b-da63-4550-a63f-c76c7e192283", "name": "fc7a501e-9c79-454e-be5c-c64f19f2ba0a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7859412473782077, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.762455747973555, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1a7e41f3-f106-40cd-b1c9-468f9c6f612b", "name": "3fce7f30-a9c4-47c8-a6fa-7dcfafdf4e9f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b92e692b-da63-4550-a63f-c76c7e192283"}}}]}, {"uuid": "e74a9ba3-c552-4ba4-ab09-d0ac5a978fcd", "name": "load_p1rlv443_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2100c17-c0e6-47e9-87f8-72016b22dd4b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1a7e41f3-f106-40cd-b1c9-468f9c6f612b"}}}}, {"uuid": "ba02ec92-c842-49fd-a668-18b6792718d9", "name": "315ec56e-8ab3-4602-b49d-bc960908c944_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1461342593009323, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5165512162199262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fc06d0ff-46e7-414c-a1a0-9fec97e1ed9a", "name": "b9047550-16e2-4235-bc0a-cdc6804ea240", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ba02ec92-c842-49fd-a668-18b6792718d9"}}}]}, {"uuid": "97174b9f-f9fe-4498-b530-e8d01c2c0522", "name": "load_p1rlv444_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30f29674-3083-4da2-95e2-a1f11a7eb7f8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fc06d0ff-46e7-414c-a1a0-9fec97e1ed9a"}}}}, {"uuid": "a686f642-643e-46b3-b1c7-f36193346147", "name": "bc70b632-df4e-49f4-a0d2-9586c52f1e8e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1461342593009323, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5165512162199262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "505ad3a5-7414-4fda-b5a4-22e9cc3d8765", "name": "393488ca-8f05-47f5-baaa-e7031131f84e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a686f642-643e-46b3-b1c7-f36193346147"}}}]}, {"uuid": "0a1432fb-6cad-4f4b-901c-b36108aedbff", "name": "load_p1rlv444_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30f29674-3083-4da2-95e2-a1f11a7eb7f8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "505ad3a5-7414-4fda-b5a4-22e9cc3d8765"}}}}, {"uuid": "697c28aa-80d6-4999-95db-098093347a29", "name": "f18426f4-6aa9-4aa9-8422-6d06a64a1243_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3269645363150677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5800133371554559, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a2eef9f-d812-4a82-ba33-8a0826a6fcfd", "name": "f4587ba9-bfbe-4da6-b1be-e6563afc89e6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "697c28aa-80d6-4999-95db-098093347a29"}}}]}, {"uuid": "7cf88d07-693e-4f44-9c68-da32cee2458a", "name": "load_p1rlv445_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d665758-71e1-4478-b39d-671f78f623e5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a2eef9f-d812-4a82-ba33-8a0826a6fcfd"}}}}, {"uuid": "93de3409-9b99-43c0-b071-432c2d9c2e37", "name": "32d226d5-0ef5-4eb9-8b29-fea2daef4505_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3269645363150677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5800133371554559, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0242c41e-10a4-437a-846a-b1ac803df3a3", "name": "212a1fef-e01a-457b-b81f-5e7385b6de57", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "93de3409-9b99-43c0-b071-432c2d9c2e37"}}}]}, {"uuid": "17ce9b5b-47c0-4564-8cd7-2905a8590713", "name": "load_p1rlv445_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d665758-71e1-4478-b39d-671f78f623e5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0242c41e-10a4-437a-846a-b1ac803df3a3"}}}}, {"uuid": "b1ebaca0-d070-46a2-baf4-37aa4cc91c98", "name": "c13b909a-5ec0-4470-982d-8d00eef6dd35_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.810132764673673, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.37076490271254653, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "47e98740-9410-49dc-bed7-d38f767046cf", "name": "626559fd-4634-49fc-8d96-151af2878a5e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b1ebaca0-d070-46a2-baf4-37aa4cc91c98"}}}]}, {"uuid": "9ee773f3-ecf1-4c59-b54e-bb9eedf8e0c5", "name": "load_p1rlv446_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acce3105-f519-491c-921a-df1294795742"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "47e98740-9410-49dc-bed7-d38f767046cf"}}}}, {"uuid": "37f518c3-137c-4023-b8ad-36e6b4dd34a9", "name": "585e9a13-274d-4cc5-bc4d-4885c2b50332_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.810132764673673, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.37076490271254653, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e968e1ca-f469-47e8-bf0f-725ddeedea33", "name": "8e71cb50-7cce-49c4-8217-d40239f37d78", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "37f518c3-137c-4023-b8ad-36e6b4dd34a9"}}}]}, {"uuid": "3bfe5804-c45b-43d3-829e-c49058179c31", "name": "load_p1rlv446_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acce3105-f519-491c-921a-df1294795742"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e968e1ca-f469-47e8-bf0f-725ddeedea33"}}}}, {"uuid": "cbbf026e-f948-4aed-be19-605541ad1420", "name": "cd7abfd6-7f0e-4a14-b7e3-ce91d3553671_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.606460911827677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.1012105340517033, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "80ccb464-d7bc-45ce-88ae-1568eed1f7df", "name": "5b26b15c-9edc-40c4-993a-8e67a69dec14", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cbbf026e-f948-4aed-be19-605541ad1420"}}}]}, {"uuid": "adcf1f3d-8e55-4089-8a27-4424b2d292dd", "name": "load_p1rlv447_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "042873fa-10df-4de0-a040-ac429b8bf7d9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "80ccb464-d7bc-45ce-88ae-1568eed1f7df"}}}}, {"uuid": "17cc2108-3c91-4142-9885-a7ab233506b5", "name": "7a1dda18-7e0c-4e50-aad9-429562d6d099_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.606460911827677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.1012105340517033, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dbe26070-4c19-4de3-8c5d-ee36a45cb679", "name": "d4c7bb47-ea9a-4416-a135-b1e974019adc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "17cc2108-3c91-4142-9885-a7ab233506b5"}}}]}, {"uuid": "3be041c5-000b-4d30-b42f-7219011ace44", "name": "load_p1rlv447_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "042873fa-10df-4de0-a040-ac429b8bf7d9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dbe26070-4c19-4de3-8c5d-ee36a45cb679"}}}}, {"uuid": "0302377c-9560-40df-b94e-7d47958e7e2f", "name": "36e137af-4506-41c5-88d4-13cc37413ad7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.241801892330501, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.45459688794228914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b76e2b4d-44de-488e-a2b0-fe0ab4d9fc6a", "name": "0fc2a879-4524-4454-8d0c-af1cd2f4ddc9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0302377c-9560-40df-b94e-7d47958e7e2f"}}}]}, {"uuid": "eab61bbb-5785-4d80-921a-cc241f8d8ffb", "name": "load_p1rlv448_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bb83d65-630d-4f1d-8e3d-8937a5a05524"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b76e2b4d-44de-488e-a2b0-fe0ab4d9fc6a"}}}}, {"uuid": "04c1ee12-8cdc-4a0f-871d-eb504a594131", "name": "f9a9fd1c-da0f-499b-8ed9-4e1e75ba09bc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.241801892330501, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.45459688794228914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a9d755ea-888b-484b-b184-f574920bbd11", "name": "31f55e2b-c26e-419e-a2d2-82d1ffb69f9a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "04c1ee12-8cdc-4a0f-871d-eb504a594131"}}}]}, {"uuid": "01eeac4e-7618-4bd3-b15c-a531cc23386a", "name": "load_p1rlv448_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bb83d65-630d-4f1d-8e3d-8937a5a05524"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a9d755ea-888b-484b-b184-f574920bbd11"}}}}, {"uuid": "f6f07fed-ee95-42bb-9b2f-99cdbcc98836", "name": "6c3bbabf-0f96-4ad5-baf6-a8243db13b5f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.290770207979584, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.15121699106508624, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a3c85719-80c2-4257-aadc-5358eebfe11b", "name": "fafbfad2-39cd-4a47-8588-f97146a2a530", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f6f07fed-ee95-42bb-9b2f-99cdbcc98836"}}}]}, {"uuid": "ba3cad7c-886c-4aec-bac5-7664880c8a25", "name": "load_p1rlv449_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "753035df-8705-48eb-92b3-c4bef603b66b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a3c85719-80c2-4257-aadc-5358eebfe11b"}}}}, {"uuid": "9fe52978-caa5-4c34-854e-f4eb88ec571f", "name": "c5e484af-10f2-4d14-882c-a3305f0f92d8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.290770207979584, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.15121699106508624, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "16df0960-22c5-4e53-895d-1586ecbecb14", "name": "6abf24ac-9d6c-4c58-a7a0-73fcf29fa5d6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9fe52978-caa5-4c34-854e-f4eb88ec571f"}}}]}, {"uuid": "fd3f66c4-070f-4567-8f8f-046fd7fc7953", "name": "load_p1rlv449_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "753035df-8705-48eb-92b3-c4bef603b66b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "16df0960-22c5-4e53-895d-1586ecbecb14"}}}}, {"uuid": "bddf4021-0bda-4b02-8584-83cb52ea6df6", "name": "573539e9-7e06-4a2e-8d2e-c61eecc3042d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.074192704000552, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.129078804753558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6529e2b5-4cec-4e70-ae8e-0fb735fc49c7", "name": "e9bfea5c-766e-4e0f-98cd-af636b88abd9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bddf4021-0bda-4b02-8584-83cb52ea6df6"}}}]}, {"uuid": "f56e4e94-fe53-4378-9421-65c4497ea5d9", "name": "load_p1rlv452_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb46f1ae-0cdb-45d1-b389-639cdf345f8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6529e2b5-4cec-4e70-ae8e-0fb735fc49c7"}}}}, {"uuid": "8baa3ae2-948d-4504-8e5f-96544b5bff7d", "name": "0704b8cb-b9f0-413b-844a-b8232935edf0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.074192704000552, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.129078804753558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "57d1c980-b6f4-4f7b-9cbe-9be88495d841", "name": "a302670d-46d5-4562-bd79-162909ef155a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8baa3ae2-948d-4504-8e5f-96544b5bff7d"}}}]}, {"uuid": "33892645-c73d-42da-9133-c45f150cfe05", "name": "load_p1rlv452_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb46f1ae-0cdb-45d1-b389-639cdf345f8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "57d1c980-b6f4-4f7b-9cbe-9be88495d841"}}}}, {"uuid": "99f3b56a-cb1e-43d1-bd43-4c73175033c1", "name": "cc4294ad-1de6-403b-b2b5-71056cc2f3fe_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2596055778412756, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4460523908595607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9b0b62d1-9bd0-450b-9454-3dae35c5bb13", "name": "66d2645b-5405-436b-a633-5b7d8b80ad2c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "99f3b56a-cb1e-43d1-bd43-4c73175033c1"}}}]}, {"uuid": "26f59976-54ab-440b-a03f-d9ddaecc9239", "name": "load_p1rlv453_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6a8a3c7-5165-48b7-8233-30d3af045442"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9b0b62d1-9bd0-450b-9454-3dae35c5bb13"}}}}, {"uuid": "7bcd775c-fb87-4ffd-be72-aa4957ceb9fc", "name": "e5e9ddd3-8c92-4393-8c95-8ff5ce52a467_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2596055778412756, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4460523908595607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "795c5ff0-765b-4d2e-84e6-b605b9f21f84", "name": "db356f00-6f24-406a-8f64-46b49003841a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7bcd775c-fb87-4ffd-be72-aa4957ceb9fc"}}}]}, {"uuid": "cd277a1a-45ef-4295-9a91-09ec9aec78d8", "name": "load_p1rlv453_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6a8a3c7-5165-48b7-8233-30d3af045442"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "795c5ff0-765b-4d2e-84e6-b605b9f21f84"}}}}, {"uuid": "af2dfd1e-d3d1-4abc-8e58-088d954abeb0", "name": "0c037c26-3125-41e7-8397-dae2b1fc74c8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4699462180170992, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3815978523472859, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bb461309-e0cf-4887-9031-9ac78ac63cb4", "name": "2b0e6d4f-78ed-4a16-b402-7009875520fe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "af2dfd1e-d3d1-4abc-8e58-088d954abeb0"}}}]}, {"uuid": "d51fe97e-f43a-4667-a760-d9a9eed3d4b7", "name": "load_p1rlv454_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3493b0ed-43a2-4602-a7ad-a817331c9d8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bb461309-e0cf-4887-9031-9ac78ac63cb4"}}}}, {"uuid": "5cad70c7-ac45-4b90-a5f3-78e154cc8341", "name": "dd000ba0-8605-43d7-8515-81e634f62533_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4699462180170992, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3815978523472859, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fc6fb7d6-1359-476d-97b1-20bd867f3a18", "name": "6598e321-ea38-42c7-a989-a50e7ae0ac62", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5cad70c7-ac45-4b90-a5f3-78e154cc8341"}}}]}, {"uuid": "215467aa-97f1-4ba5-8bcf-bad6a898e4f8", "name": "load_p1rlv454_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3493b0ed-43a2-4602-a7ad-a817331c9d8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fc6fb7d6-1359-476d-97b1-20bd867f3a18"}}}}, {"uuid": "c1266b4d-e8a3-48a2-9297-e10fe963cf5e", "name": "29fc98bb-2656-41f5-ad5e-1431eb3fb30b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5202593896091736, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6973445820856009, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "96cd17e7-f798-45b1-8136-6e07bd96d687", "name": "2bbad14f-f795-44e7-8b67-3c821ac4df2b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c1266b4d-e8a3-48a2-9297-e10fe963cf5e"}}}]}, {"uuid": "f0320455-ed71-4eeb-b7cb-3891fd5c8df6", "name": "load_p1rlv455_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "552153cc-f5be-42ee-9985-9361c2e7e2a1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "96cd17e7-f798-45b1-8136-6e07bd96d687"}}}}, {"uuid": "4a5816d1-5d8a-4d59-9761-844ac1fca02d", "name": "de884caa-1c0a-4d92-9115-9f212e96e999_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5202593896091736, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6973445820856009, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "20c248bc-ee70-493f-abc6-aef541a4bb02", "name": "0837a3bd-373a-4210-b7ca-d37bd7aac7cd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4a5816d1-5d8a-4d59-9761-844ac1fca02d"}}}]}, {"uuid": "e503e50d-78e4-4333-bd39-09478619af1c", "name": "load_p1rlv455_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "552153cc-f5be-42ee-9985-9361c2e7e2a1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "20c248bc-ee70-493f-abc6-aef541a4bb02"}}}}, {"uuid": "6d04a185-16bf-47d6-9f92-deb00c1096f4", "name": "78026fdd-52f3-43d6-bb7e-c54fee37d7d9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.664483224984605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9538644530515166, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "704246ad-9aa3-4b64-8adc-72cdeefbf279", "name": "450c3cf4-a57c-4818-9ed7-c910ce08ddae", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6d04a185-16bf-47d6-9f92-deb00c1096f4"}}}]}, {"uuid": "04d7b81b-9fb7-418b-b8ae-51d232702c4d", "name": "load_p1rlv456_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85f0d94e-c096-4d53-ae05-f0dc59f73d02"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "704246ad-9aa3-4b64-8adc-72cdeefbf279"}}}}, {"uuid": "f8906971-5101-4f75-a721-5b7cc3867d5d", "name": "a6fbb3e3-65df-4eaf-8ea6-1ce7d4ce30c2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.664483224984605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9538644530515166, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bda896e9-bf5f-4151-aea7-4cb9f002a0f3", "name": "0305c1c2-bb42-495e-b37e-c56caa95ae85", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8906971-5101-4f75-a721-5b7cc3867d5d"}}}]}, {"uuid": "b3693e19-7baa-4575-ab10-58ea8a3303e5", "name": "load_p1rlv456_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85f0d94e-c096-4d53-ae05-f0dc59f73d02"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bda896e9-bf5f-4151-aea7-4cb9f002a0f3"}}}}, {"uuid": "07259dfc-789d-432d-b8a8-7201249a0d4a", "name": "f9e0814c-a28f-4273-af2f-71fc3f0ddb91_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.001928314210379, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4572901775510755, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8e28387d-892b-4c4a-9bfc-5d99ddc34b9d", "name": "5ade5781-13d3-48eb-92c9-b1b1b675db52", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "07259dfc-789d-432d-b8a8-7201249a0d4a"}}}]}, {"uuid": "6396f646-0b7b-4db8-905b-1aaa0fc529ac", "name": "load_p1rlv457_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6278f6ee-7332-4de8-9d2c-83bb637f489f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8e28387d-892b-4c4a-9bfc-5d99ddc34b9d"}}}}, {"uuid": "eef9909b-7dfb-4201-ba64-64972a7510b2", "name": "659fa35c-9f5f-4372-8a85-75793de72145_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.001928314210379, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4572901775510755, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f0beaee8-0dff-41be-8079-7008b9f38793", "name": "39099389-cdfc-4a1f-816c-c93dfa19271a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eef9909b-7dfb-4201-ba64-64972a7510b2"}}}]}, {"uuid": "cd573da9-d64f-4198-8f46-34a079f6602d", "name": "load_p1rlv457_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6278f6ee-7332-4de8-9d2c-83bb637f489f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f0beaee8-0dff-41be-8079-7008b9f38793"}}}}, {"uuid": "c788b54e-b76d-42bb-b55d-f9517ddd652b", "name": "fdfcd836-32ea-4c57-a20d-a8d0068a30d3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.24613321897865, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9528039237137753, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f06e3d1c-158f-416f-a682-7a7e66916b4c", "name": "2600ca77-2070-413e-9efb-f80804cb32fe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c788b54e-b76d-42bb-b55d-f9517ddd652b"}}}]}, {"uuid": "33524da1-876d-4466-9090-b54091e6186f", "name": "load_p1rlv458_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec66e302-748d-4300-ba65-719de0a906bb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f06e3d1c-158f-416f-a682-7a7e66916b4c"}}}}, {"uuid": "00b54568-a399-4168-b6b2-108bddace79b", "name": "3684c6ad-023a-42d3-be59-ed89bf121656_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.24613321897865, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9528039237137753, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2a2dfb4e-141c-4d8d-a7de-4dad5ba04eb7", "name": "05729729-e11a-4080-8e71-641b55183fda", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "00b54568-a399-4168-b6b2-108bddace79b"}}}]}, {"uuid": "c1a77fe8-1909-4bc7-ae97-94b06c52435b", "name": "load_p1rlv458_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec66e302-748d-4300-ba65-719de0a906bb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2a2dfb4e-141c-4d8d-a7de-4dad5ba04eb7"}}}}, {"uuid": "a03db4c5-93b6-4bd5-8db4-6a563dcdb30e", "name": "6aa860cd-622e-4014-af12-abc266d26b30_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.502751049099443, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7555421856436744, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ba26bf17-ab63-4273-a0bb-faf9bad4de4c", "name": "717ae0b6-4d1f-464a-a299-f077fbb35b0a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a03db4c5-93b6-4bd5-8db4-6a563dcdb30e"}}}]}, {"uuid": "f23ab323-54c8-435f-b1fd-8e60cf8cd52c", "name": "load_p1rlv459_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c112196-bcbc-41bc-99a9-f3657c335c7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ba26bf17-ab63-4273-a0bb-faf9bad4de4c"}}}}, {"uuid": "8ef17114-2bb3-45d9-841e-3bd09e0e7c5f", "name": "90727a7c-dec7-417b-b2f0-57aab2169b89_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.502751049099443, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7555421856436744, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3a502be6-0db3-4667-b815-6a8ee1a44e72", "name": "4a9ecb98-9a3c-4d9b-a503-5e0e697e9acd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ef17114-2bb3-45d9-841e-3bd09e0e7c5f"}}}]}, {"uuid": "f800f59e-b573-4dfb-8d51-8b8de0ced0be", "name": "load_p1rlv459_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c112196-bcbc-41bc-99a9-f3657c335c7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3a502be6-0db3-4667-b815-6a8ee1a44e72"}}}}, {"uuid": "e36a1032-84f7-47fb-99f7-ba68f0b1c98f", "name": "f9131d78-d7bf-409d-804a-fc58fdaac44d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8202631342288826, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.26720803692022926, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0cf0611e-cc09-4f7e-a2bd-4fd7c593d2f4", "name": "0e0565b4-bd83-4f37-81b9-95f041a12d3e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e36a1032-84f7-47fb-99f7-ba68f0b1c98f"}}}]}, {"uuid": "bb55e834-c0df-4bda-8242-dcccf3fe15eb", "name": "load_p1rlv460_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76b212f9-2e27-4064-a2c5-079786afb1d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0cf0611e-cc09-4f7e-a2bd-4fd7c593d2f4"}}}}, {"uuid": "2b4a72cb-bb3d-4bc4-bd92-709af163a462", "name": "928a7425-e29f-43af-abfa-86f7dc12bd20_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8202631342288826, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.26720803692022926, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "86cc4222-c03b-482f-90aa-46d44bb2aeef", "name": "9df527a7-87df-4771-bbfc-7d7d2a3f0eff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2b4a72cb-bb3d-4bc4-bd92-709af163a462"}}}]}, {"uuid": "3071b825-5459-4be8-8b76-f333c316f4c7", "name": "load_p1rlv460_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76b212f9-2e27-4064-a2c5-079786afb1d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "86cc4222-c03b-482f-90aa-46d44bb2aeef"}}}}, {"uuid": "1681dc0a-7a40-434e-8dba-1f19db51925a", "name": "bbe8984b-a62b-45d1-b9f7-12adcba1965e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4622944887503224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10483650830237357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5152946d-17ad-452a-8d50-3ab5b14d25ec", "name": "c3dc8d70-ae93-40ba-b524-b4d321e9f59f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1681dc0a-7a40-434e-8dba-1f19db51925a"}}}]}, {"uuid": "77243974-dd20-4014-b17d-913466af3faf", "name": "load_p1rlv461_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76dd0f1b-4109-4707-a547-f0ab1b6e148f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5152946d-17ad-452a-8d50-3ab5b14d25ec"}}}}, {"uuid": "7578199c-24c3-47ee-8412-ae5e4b092da4", "name": "5bdbdf12-504c-40f1-947d-aa28ee8f89ae_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4622944887503224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10483650830237357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1af4b0d4-e28b-424b-9db1-b7e5869961ab", "name": "6beb972c-9312-4ba8-be20-e79b4ada60e2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7578199c-24c3-47ee-8412-ae5e4b092da4"}}}]}, {"uuid": "a432c673-e52c-41e5-9676-f3fb7b3a04af", "name": "load_p1rlv461_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76dd0f1b-4109-4707-a547-f0ab1b6e148f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1af4b0d4-e28b-424b-9db1-b7e5869961ab"}}}}, {"uuid": "74ed2102-5079-49a3-961d-c854ee51c3cf", "name": "70864144-ffa6-4574-9ecc-4a5c7a3a4b29_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3786182488338723, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5359363058124609, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8b5d7657-81f0-47be-bf22-bebb1d57940b", "name": "caf9718a-fa65-4a51-9361-02be5286f5a6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "74ed2102-5079-49a3-961d-c854ee51c3cf"}}}]}, {"uuid": "f07a0d15-0adc-40e9-aa3c-e16810c2f41e", "name": "load_p1rlv462_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9176da24-7eb5-4b0b-99dd-886c3f974798"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8b5d7657-81f0-47be-bf22-bebb1d57940b"}}}}, {"uuid": "144dbe08-6967-4a00-8ff3-45902a02f650", "name": "8c97b50e-20d1-4d7f-9104-ac19c7d6d5c7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3786182488338723, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5359363058124609, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eb331271-5ef8-45ee-98a5-5e50fea9bb53", "name": "ead2c979-3975-4844-801f-17fa2f40abd4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "144dbe08-6967-4a00-8ff3-45902a02f650"}}}]}, {"uuid": "dbb406a5-e5db-4542-bab9-85656860b5cc", "name": "load_p1rlv462_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9176da24-7eb5-4b0b-99dd-886c3f974798"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eb331271-5ef8-45ee-98a5-5e50fea9bb53"}}}}, {"uuid": "c9b8b2db-fc98-4b73-9372-7b7f56fc06fd", "name": "d38aa64b-6817-4902-b4af-29d0405521ac_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.746284303820433, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6724067157838972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8affc3e7-cc33-47aa-8b64-46f8752acfd2", "name": "832568a2-1b70-43bd-b287-a8ecc7b6008e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9b8b2db-fc98-4b73-9372-7b7f56fc06fd"}}}]}, {"uuid": "bbb2b72b-01b7-4567-a526-08186d132dff", "name": "load_p1rlv463_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff9d9cca-1878-478d-a190-b58c9098f13e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8affc3e7-cc33-47aa-8b64-46f8752acfd2"}}}}, {"uuid": "8493882e-5fe4-4431-b91d-23f766fb3835", "name": "2b44ede7-f0d3-40cf-9ef5-3911382d78f7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.746284303820433, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6724067157838972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7f0a4bf9-4787-4faf-b94f-27e068b9fd23", "name": "ae16dc1f-98a8-471a-8950-fc2f7856f811", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8493882e-5fe4-4431-b91d-23f766fb3835"}}}]}, {"uuid": "0692a8dd-5767-4faa-8ed2-22f06e6818a5", "name": "load_p1rlv463_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff9d9cca-1878-478d-a190-b58c9098f13e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7f0a4bf9-4787-4faf-b94f-27e068b9fd23"}}}}, {"uuid": "90b9c581-1af5-4535-a4e6-5c0bb62f15cd", "name": "589c50c8-66ad-464a-b072-b39b7b629c8e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6697995975485909, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.41657408993223344, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bdff3310-45b0-4cd2-9fbb-76ac2646ed22", "name": "a584c625-4eaf-4447-a60f-da33dbd2aad3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "90b9c581-1af5-4535-a4e6-5c0bb62f15cd"}}}]}, {"uuid": "0ac20aca-a1b8-4ca7-8af5-c18603f14c87", "name": "load_p1rlv464_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "895d0235-3ee6-4f06-9978-9d615d721ebd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bdff3310-45b0-4cd2-9fbb-76ac2646ed22"}}}}, {"uuid": "045e93db-d4b2-4939-8648-121b125682a9", "name": "78c10fdf-2c51-4a7e-b931-5f4249b795a5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6697995975485909, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.41657408993223344, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1836608f-4a1a-4787-a25b-a3e6d90cf0fb", "name": "40119705-7971-4e0c-9403-92879dc6f264", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "045e93db-d4b2-4939-8648-121b125682a9"}}}]}, {"uuid": "70712bd9-cf0d-4d57-b077-5f8c62d2c443", "name": "load_p1rlv464_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "895d0235-3ee6-4f06-9978-9d615d721ebd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1836608f-4a1a-4787-a25b-a3e6d90cf0fb"}}}}, {"uuid": "23f7b572-b420-4566-a98c-b0957a8d3705", "name": "5540f6f1-1e88-429e-8a19-7fbed822563b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.39658717665728, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7677987041236869, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "231541f9-de2a-43fe-8f6d-b1fa16116d70", "name": "68e7af5f-ee63-47a5-9fbc-85802e26b14b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "23f7b572-b420-4566-a98c-b0957a8d3705"}}}]}, {"uuid": "4dbb057b-7a4c-46b0-b651-b7953221ee68", "name": "load_p1rlv474_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e589527-d388-4364-87d2-2f4af1a14509"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "231541f9-de2a-43fe-8f6d-b1fa16116d70"}}}}, {"uuid": "a1f1dbc9-434a-4bda-a3be-744652481039", "name": "c1626b19-390a-438b-bb22-3a67618e84e3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.39658717665728, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7677987041236869, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e05045f9-527b-4c22-b442-7e07341cff95", "name": "16229ae1-0f2c-49a1-b497-ecb55f58586d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a1f1dbc9-434a-4bda-a3be-744652481039"}}}]}, {"uuid": "a2b46400-933c-4daf-8d8a-0db79c8d68c8", "name": "load_p1rlv474_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e589527-d388-4364-87d2-2f4af1a14509"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e05045f9-527b-4c22-b442-7e07341cff95"}}}}, {"uuid": "abf3daaf-3351-4985-aa87-859e07d1038e", "name": "3aa690da-241d-46f3-bb64-0117330bb2c2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0286208645240644, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.052486030755511705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "55898de9-b406-4e16-9444-fc188a12b038", "name": "a5533b53-cc31-4481-93a7-e7a1a2fe8c05", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "abf3daaf-3351-4985-aa87-859e07d1038e"}}}]}, {"uuid": "043b62da-c1eb-4c2e-98d3-267b9c8c764c", "name": "load_p1rlv480_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb55ec0b-b6f7-48a7-8dae-dda95fc34499"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "55898de9-b406-4e16-9444-fc188a12b038"}}}}, {"uuid": "fb39a764-5af3-48da-9038-0a882971a76f", "name": "ae6d6173-39cd-4f95-a615-43c904298ad5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0286208645240644, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.052486030755511705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d268605c-e163-4f4e-a55d-89769662b069", "name": "1ce324fd-d025-41ff-b7a3-c63373a72816", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fb39a764-5af3-48da-9038-0a882971a76f"}}}]}, {"uuid": "f055d64c-5f91-48e8-a3a0-3e00176d588a", "name": "load_p1rlv480_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb55ec0b-b6f7-48a7-8dae-dda95fc34499"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d268605c-e163-4f4e-a55d-89769662b069"}}}}, {"uuid": "01d86a82-6b19-4195-af70-50b97e15278b", "name": "0ce8fcdc-7ce8-4c03-8425-b80a2e092b64_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.344060161619426, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2705527109429713, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "084a4884-2c0f-4fc8-9f28-9ef621e2d7db", "name": "df7e8996-7993-4e74-86f4-57f32eec8344", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "01d86a82-6b19-4195-af70-50b97e15278b"}}}]}, {"uuid": "9d37f739-515f-41ac-95e3-b2c68f6180f2", "name": "load_p1rlv481_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d9e77ad-42c6-4413-96e6-debfed3c442a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "084a4884-2c0f-4fc8-9f28-9ef621e2d7db"}}}}, {"uuid": "55980176-93de-43e5-b013-471374eb1320", "name": "635de8d9-6a09-4e38-b23f-1f821810a8c3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.344060161619426, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2705527109429713, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4ff8aadf-bf74-4264-afc9-654c2b1a74d2", "name": "0a1e8ade-aee1-422e-8547-341980381f49", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "55980176-93de-43e5-b013-471374eb1320"}}}]}, {"uuid": "f6153836-4bed-404c-bdf1-63eb9f24e1f9", "name": "load_p1rlv481_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d9e77ad-42c6-4413-96e6-debfed3c442a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4ff8aadf-bf74-4264-afc9-654c2b1a74d2"}}}}, {"uuid": "aa79d731-94a7-48dd-8d59-5d7e0353e921", "name": "f68c64e8-6ce9-4752-b6f1-f633305cc042_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7771517670040275, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8838563298920215, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "346e1f94-ef53-4328-85d8-3e731cbed0bc", "name": "b543513b-8bbd-4ee6-af00-6b2c45657b65", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aa79d731-94a7-48dd-8d59-5d7e0353e921"}}}]}, {"uuid": "5330f48f-076b-49f1-82a8-aa95d814afc0", "name": "load_p1rlv482_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d4b708f-cc15-4ee3-87e0-4d26fec02f1e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "346e1f94-ef53-4328-85d8-3e731cbed0bc"}}}}, {"uuid": "fa809bda-ab1f-468c-a1c0-00ae4155b327", "name": "1df30ee9-3d2f-4c8e-b8f7-1c8c8560c726_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7771517670040275, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8838563298920215, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "61d43de4-349e-45e0-9fad-ca8b5cb8a96b", "name": "222bd2f6-8ef5-451f-99d4-e12b6a9b7b18", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fa809bda-ab1f-468c-a1c0-00ae4155b327"}}}]}, {"uuid": "d784bc94-505d-48cc-9eb3-5d431ef40017", "name": "load_p1rlv482_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d4b708f-cc15-4ee3-87e0-4d26fec02f1e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "61d43de4-349e-45e0-9fad-ca8b5cb8a96b"}}}}, {"uuid": "1825ac5b-af7c-47f2-9768-71fb16fe3580", "name": "7e3d9b34-b59b-4b5f-80c0-4b6df9e76ec6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.028781788264419, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6709073147144231, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "75baf9e4-7868-4e67-b246-614b1840a719", "name": "1027a59c-2df8-4068-94f2-2a7dce473b00", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1825ac5b-af7c-47f2-9768-71fb16fe3580"}}}]}, {"uuid": "5f58554e-ae27-4ee3-b8ce-2ce2b4da05e1", "name": "load_p1rlv483_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d059a618-6f09-404b-b1a0-0e7aa0c55c45"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "75baf9e4-7868-4e67-b246-614b1840a719"}}}}, {"uuid": "3bc1d7e1-1784-42d6-8c39-e8e06455df71", "name": "4a61aa61-fe56-4b0f-9a5f-2f33c303efd8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.028781788264419, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6709073147144231, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f0079fd6-6054-417f-8616-d1e9750b4fae", "name": "b2202614-2c1e-42be-9eda-0fc84316a583", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3bc1d7e1-1784-42d6-8c39-e8e06455df71"}}}]}, {"uuid": "9a558047-9b01-41d0-848f-110b5dc5a875", "name": "load_p1rlv483_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d059a618-6f09-404b-b1a0-0e7aa0c55c45"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f0079fd6-6054-417f-8616-d1e9750b4fae"}}}}, {"uuid": "7fd86059-1fb0-4850-8383-80f9c0d89b07", "name": "78b7cde0-9788-4784-bda5-b2e87c3762ce_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2cae686a-7690-4c89-87fb-f6411445c88a", "name": "4b8f45ca-515d-4011-beb3-1d7dff9174f4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7fd86059-1fb0-4850-8383-80f9c0d89b07"}}}]}, {"uuid": "0a5c43a0-66a6-47dc-a6a2-81c017f57312", "name": "load_p1rlv484_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fde62b60-c5f6-44d6-b2f2-211c21b02033"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2cae686a-7690-4c89-87fb-f6411445c88a"}}}}, {"uuid": "91f21c3a-09a1-463e-bd18-697a4cef3d1d", "name": "cae84f22-cbc8-4490-87ec-65a09cce4be7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c22693f2-4e3e-4332-90df-348f8224e354", "name": "ed9ef4a6-f1f0-4298-a291-139014d1ed1b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "91f21c3a-09a1-463e-bd18-697a4cef3d1d"}}}]}, {"uuid": "2efcaf50-890a-472b-8585-0b0aed28c88c", "name": "load_p1rlv484_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fde62b60-c5f6-44d6-b2f2-211c21b02033"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c22693f2-4e3e-4332-90df-348f8224e354"}}}}, {"uuid": "7c82752e-6238-4694-b6fc-1de01350b614", "name": "0a2fdbf3-b2e1-4e28-bda9-b206aeef6354_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1427818095792333, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033588044558321, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bede68a2-9953-41f7-81c5-67e173e1f7b5", "name": "b81a309e-cfd3-495d-8bc6-b8876ab86522", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7c82752e-6238-4694-b6fc-1de01350b614"}}}]}, {"uuid": "961d3415-4d1b-469d-ad95-d2fb2cba8f9f", "name": "load_p1rlv485_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d2c379-7e19-46c4-8c6e-533fa9db7764"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bede68a2-9953-41f7-81c5-67e173e1f7b5"}}}}, {"uuid": "c9782cba-ea23-4cc0-8eeb-ab8863e342d1", "name": "e23f1faf-8f46-47c3-9fcb-ecf840026784_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1427818095792333, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033588044558321, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2cbeff2f-e022-4b7d-84c0-a0669e5273fc", "name": "15584f6e-d34b-4bab-a9b2-27de606bf26a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9782cba-ea23-4cc0-8eeb-ab8863e342d1"}}}]}, {"uuid": "71f48568-c9c7-48f3-b31a-c98da55e2867", "name": "load_p1rlv485_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d2c379-7e19-46c4-8c6e-533fa9db7764"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2cbeff2f-e022-4b7d-84c0-a0669e5273fc"}}}}, {"uuid": "ef005c11-6613-4d1f-a3f9-ef1660f354cc", "name": "8574ce8c-c0ac-458f-b3d1-5d56ab2dfd00_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5348201699646123, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21241824123648728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f345581f-8b31-49e3-b909-744fd85f1da8", "name": "2583cce9-86fe-4153-b471-f6f480cd262f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ef005c11-6613-4d1f-a3f9-ef1660f354cc"}}}]}, {"uuid": "d781c621-8a08-4bd9-8932-b022ced80680", "name": "load_p1rlv486_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a54b2228-9e7d-4e6b-939d-ab2765454522"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f345581f-8b31-49e3-b909-744fd85f1da8"}}}}, {"uuid": "8b485a7f-3820-452a-ad3a-dbf638044106", "name": "f82bda5c-6bd7-457a-bd8d-5a3d236abcc9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5348201699646123, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21241824123648728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eb877549-0aa6-41ab-a159-3eb8f8a8d16e", "name": "7ec9eede-273c-464c-8684-5216cab393e3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8b485a7f-3820-452a-ad3a-dbf638044106"}}}]}, {"uuid": "7c85c75e-9c64-411f-b5f6-fc3e067e7dad", "name": "load_p1rlv486_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a54b2228-9e7d-4e6b-939d-ab2765454522"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eb877549-0aa6-41ab-a159-3eb8f8a8d16e"}}}}, {"uuid": "37587ae2-c7e3-4b8e-bc53-2e1bd69f1b94", "name": "dbb8d51a-9d04-47a0-8808-9d984c3f20b9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.735884899619907, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7862059386133167, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2a04339c-e49e-4079-8dfa-72d503319bb3", "name": "ed24707c-33ab-4e77-a007-3fc31e829c35", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "37587ae2-c7e3-4b8e-bc53-2e1bd69f1b94"}}}]}, {"uuid": "caa60bdc-63e7-41df-9f56-3480e49958e3", "name": "load_p1rlv487_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2d5799-907e-46fd-a389-120aea352775"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2a04339c-e49e-4079-8dfa-72d503319bb3"}}}}, {"uuid": "635823f5-2af2-4722-8628-1c8309c068f0", "name": "53db1c7b-b1ea-4eda-804a-4739b66213c7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.735884899619907, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7862059386133167, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "785d5de7-2553-4f05-8d72-6e79c2b533a0", "name": "de29166c-4d19-4cc6-a3ba-2cfc74254d6d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "635823f5-2af2-4722-8628-1c8309c068f0"}}}]}, {"uuid": "492910aa-850c-43d9-8fd0-a8b444dd4d33", "name": "load_p1rlv487_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2d5799-907e-46fd-a389-120aea352775"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "785d5de7-2553-4f05-8d72-6e79c2b533a0"}}}}, {"uuid": "114a88fc-4cce-4a85-8877-b8af701eb28b", "name": "f66e6768-368c-4b9a-93d1-5bfa67109daa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4382677398578904, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21115535117680156, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "15e403be-c270-4b31-b9ee-89554f382fd3", "name": "3905f176-648c-47db-9614-82224653a856", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "114a88fc-4cce-4a85-8877-b8af701eb28b"}}}]}, {"uuid": "119a4e4a-f6be-4b55-9900-87c023e626f3", "name": "load_p1rlv523_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97c38794-7c60-4ff8-b09b-7503c9604409"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "15e403be-c270-4b31-b9ee-89554f382fd3"}}}}, {"uuid": "494fd173-51a7-443c-8d92-b653a872f414", "name": "343b7015-d5e0-4d33-9063-52885cdf5728_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4382677398578904, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21115535117680156, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c61863b-4b03-449a-ba74-5a0b3b6f1240", "name": "517586d4-15d7-438c-865e-10fa3790e5ad", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "494fd173-51a7-443c-8d92-b653a872f414"}}}]}, {"uuid": "42101e58-1bef-43a2-8cf3-8b619ff04974", "name": "load_p1rlv523_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97c38794-7c60-4ff8-b09b-7503c9604409"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c61863b-4b03-449a-ba74-5a0b3b6f1240"}}}}, {"uuid": "44f33879-a83f-42d3-b0fd-b054eebfa36c", "name": "d5a8bbba-4bf9-4548-b809-990af5652257_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0716401691896973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6949594139700135, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b670fe47-e049-4a45-bd32-37a9bddc3c4a", "name": "c20e5090-9efa-4101-9164-97e4f547dc7b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "44f33879-a83f-42d3-b0fd-b054eebfa36c"}}}]}, {"uuid": "023c8818-27f6-42ae-a0a0-75b5b12371d4", "name": "load_p1rlv524_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bef074be-aac4-4d82-a832-641729756802"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b670fe47-e049-4a45-bd32-37a9bddc3c4a"}}}}, {"uuid": "3eaf7dfa-6b10-49c8-9220-412dd0c53f54", "name": "b174c88c-0b68-4811-a183-e2455e7deccd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0716401691896973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6949594139700135, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7dd02363-2c3f-4a2d-b42a-cf75c83efe12", "name": "babb8a4d-c0a4-4183-bfb7-5f5a6f2d9682", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3eaf7dfa-6b10-49c8-9220-412dd0c53f54"}}}]}, {"uuid": "7490587f-d2a9-4d03-b135-bf1f15912727", "name": "load_p1rlv524_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bef074be-aac4-4d82-a832-641729756802"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7dd02363-2c3f-4a2d-b42a-cf75c83efe12"}}}}, {"uuid": "0daa0bde-626f-4c61-91dc-fd9fcbd0228f", "name": "59d87379-9909-4561-9fe0-803c1cc97921_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6848010607962993, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6615616037111118, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "668bb1d4-8d20-4fc2-b12a-c853b2093b6c", "name": "ef894c10-fdff-4acf-8a4f-28340bd89565", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0daa0bde-626f-4c61-91dc-fd9fcbd0228f"}}}]}, {"uuid": "89affe1d-df30-4472-aa79-d9d41a960af9", "name": "load_p1rlv525_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a42f8b99-82c6-4c90-81ea-6ccb38eacfab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "668bb1d4-8d20-4fc2-b12a-c853b2093b6c"}}}}, {"uuid": "eceeb9ce-cae8-464e-a1dd-f974d4982328", "name": "da7affbb-c986-4a59-aebe-0921c814e735_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6848010607962993, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6615616037111118, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "827c6e55-1c05-4aec-977d-63675c508fce", "name": "0c6e6671-1359-4d87-912d-0245395bea05", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eceeb9ce-cae8-464e-a1dd-f974d4982328"}}}]}, {"uuid": "565dc000-ec57-49d2-b399-cdc496915202", "name": "load_p1rlv525_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a42f8b99-82c6-4c90-81ea-6ccb38eacfab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "827c6e55-1c05-4aec-977d-63675c508fce"}}}}, {"uuid": "6fce8211-ec65-4b35-b79a-3e48952231d3", "name": "3c91c04b-92ea-45f7-9066-7c4023db5805_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9444657359992037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.058006608995704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4c12a34f-4cc3-44ff-b6a1-a2d2e06a2d01", "name": "5e5d11ea-47a7-4336-913a-e6e84156ba69", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6fce8211-ec65-4b35-b79a-3e48952231d3"}}}]}, {"uuid": "702b22c3-6391-4c00-b2a0-213473b1de53", "name": "load_p1rlv526_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ab8e220-faf9-4108-80f8-22d2fe326c3d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4c12a34f-4cc3-44ff-b6a1-a2d2e06a2d01"}}}}, {"uuid": "8612b553-2a6f-4eb5-95d6-19616c0c0001", "name": "1eac6aa3-3aa4-4f02-9e94-8b3f243b0661_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9444657359992037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.058006608995704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d30d2b5d-97a4-4bcd-8926-9437ae9121e2", "name": "2d8fbce5-1be7-41ca-87ed-b35b6f047dba", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8612b553-2a6f-4eb5-95d6-19616c0c0001"}}}]}, {"uuid": "f25a304e-9871-4686-8346-4e54947de4a3", "name": "load_p1rlv526_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ab8e220-faf9-4108-80f8-22d2fe326c3d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d30d2b5d-97a4-4bcd-8926-9437ae9121e2"}}}}, {"uuid": "c4adf770-4bf0-4ff9-b5e8-a2c0b0b0ed8f", "name": "59be0bf8-dd2b-4ee8-86ff-94aae3288264_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6722127407962883, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033140171384262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a6bdab56-e0b0-4621-8573-17afc2217e60", "name": "72ac885e-4a24-491b-bc5f-2df60f7c5985", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c4adf770-4bf0-4ff9-b5e8-a2c0b0b0ed8f"}}}]}, {"uuid": "1f909f54-5f67-4499-805b-268740afd001", "name": "load_p1rlv531_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32a1d9d7-31c7-4def-88d4-e4d41bd21572"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a6bdab56-e0b0-4621-8573-17afc2217e60"}}}}, {"uuid": "d0306536-ef63-46b5-8ad7-b0c2012c02ce", "name": "e6f65fcf-9b46-4b85-b626-363e8e3abf2c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6722127407962883, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033140171384262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a5029a49-6811-4590-9b37-08466159575e", "name": "8ba2dbc3-975d-4a74-9ad2-aab7450cacc3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d0306536-ef63-46b5-8ad7-b0c2012c02ce"}}}]}, {"uuid": "d29693fc-93cc-4dcb-a81e-ec915a22a887", "name": "load_p1rlv531_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32a1d9d7-31c7-4def-88d4-e4d41bd21572"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a5029a49-6811-4590-9b37-08466159575e"}}}}, {"uuid": "ff1ce328-5ff0-4a6a-8cc3-720b36e308db", "name": "3901e228-d7d3-4c2b-9623-61fcdd03d1d2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.813063869628266, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3555509200852155, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aa62e060-7c3f-4658-a5bb-6ac27d8eab7e", "name": "df21c81a-f687-4bfe-9a36-e095194a10cf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ff1ce328-5ff0-4a6a-8cc3-720b36e308db"}}}]}, {"uuid": "1bf2ee86-4b3a-4a51-bd37-3c02cc5b2eb2", "name": "load_p1rlv532_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1362feeb-2e2c-4dd1-9f49-239c952c6120"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aa62e060-7c3f-4658-a5bb-6ac27d8eab7e"}}}}, {"uuid": "2d4d05d7-da58-4665-ad42-9d5aaf1c1cc8", "name": "c15b620e-3633-49f2-946b-5e9f3ff7ee89_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.813063869628266, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3555509200852155, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f2a566e1-d88c-4f40-93e4-eb51f9da04d1", "name": "99fd0bef-ba99-4d29-ab3f-d0833baaa501", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2d4d05d7-da58-4665-ad42-9d5aaf1c1cc8"}}}]}, {"uuid": "4bbb646b-f5e5-434a-9150-ae55074d0217", "name": "load_p1rlv532_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1362feeb-2e2c-4dd1-9f49-239c952c6120"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f2a566e1-d88c-4f40-93e4-eb51f9da04d1"}}}}, {"uuid": "d10892f4-2562-4589-abbb-e58c3bbbdbe5", "name": "9dcb1517-15a2-4fcd-949e-c7735a62b8eb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.789788128831495, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 5.104197877675544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d15b6add-9538-4b27-8b4f-eebe82806984", "name": "67e36378-dce1-4fd2-9824-8f9da766bd2c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d10892f4-2562-4589-abbb-e58c3bbbdbe5"}}}]}, {"uuid": "ad822df3-0d76-4929-945d-38f5589067a4", "name": "load_p1rlv533_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f79bc5f-375f-4ecd-b828-eb7b137d7cab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d15b6add-9538-4b27-8b4f-eebe82806984"}}}}, {"uuid": "ae02b387-1fd5-4a79-8eed-9a740d62b494", "name": "4823141d-b517-4d47-9c11-5a9d94ba773f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.789788128831495, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 5.104197877675544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "99541b60-fd2b-4302-bed5-43ba04e59d08", "name": "8099a6a3-dd55-4a38-a314-51295e3bfa2a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ae02b387-1fd5-4a79-8eed-9a740d62b494"}}}]}, {"uuid": "c2badedc-6ebd-477c-9ff0-9d83cd96671f", "name": "load_p1rlv533_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f79bc5f-375f-4ecd-b828-eb7b137d7cab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "99541b60-fd2b-4302-bed5-43ba04e59d08"}}}}, {"uuid": "6fd8c910-05ab-4e2e-96ca-a0bf62a01f30", "name": "8d91e304-d583-4a4b-862e-370c05d9fbe4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.504585200899067, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1614896338945686, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "90ff893c-5696-4cba-a481-4a0bb14f3407", "name": "ae047cdb-aeef-4a48-a4c9-b5f1e0c2c7c3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6fd8c910-05ab-4e2e-96ca-a0bf62a01f30"}}}]}, {"uuid": "43ed6dc8-dc77-4444-bf68-f73ff89a3407", "name": "load_p1rlv534_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0eb7074c-0745-4089-9329-aa3495f9b460"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "90ff893c-5696-4cba-a481-4a0bb14f3407"}}}}, {"uuid": "cedc9d19-d4d6-4694-a37c-887b76cad22f", "name": "9064d56b-453f-427f-98e9-e6bbff3cbfc1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.504585200899067, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1614896338945686, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3a43066d-745a-46de-982f-db83487f1a5f", "name": "d5034cec-1823-4361-8099-fa7676d8340e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cedc9d19-d4d6-4694-a37c-887b76cad22f"}}}]}, {"uuid": "d6d0bf46-ec50-4d26-b2d2-9fbf24a065cb", "name": "load_p1rlv534_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0eb7074c-0745-4089-9329-aa3495f9b460"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3a43066d-745a-46de-982f-db83487f1a5f"}}}}, {"uuid": "8eb73e5a-26ba-49e3-87b4-22016ac4eb9d", "name": "12013ea5-b812-4b9b-ad08-995006bf8ba9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.469077677978515, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3943727551399522, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b5b64d97-745a-4e70-b8d7-dce5eb3aadfc", "name": "ae3f01dd-2c40-41ef-bdf2-e9af34d6c3e7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8eb73e5a-26ba-49e3-87b4-22016ac4eb9d"}}}]}, {"uuid": "5a3c7273-5a95-4fd9-9e3a-4abfb773fbd2", "name": "load_p1rlv535_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9cc91945-564c-4ace-bb53-77150b107b41"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b5b64d97-745a-4e70-b8d7-dce5eb3aadfc"}}}}, {"uuid": "315291bc-784c-4b13-8505-fd4e1186ae77", "name": "9a714b62-4a2c-4c1d-97c4-7b429b3fffa9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.469077677978515, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3943727551399522, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eaa12b68-16e4-4231-8b3c-10991027b469", "name": "544f1730-6a8c-4030-83ff-11bc4f5f839f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "315291bc-784c-4b13-8505-fd4e1186ae77"}}}]}, {"uuid": "c7984dc5-3d90-44ff-9829-6ac742cd1eed", "name": "load_p1rlv535_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9cc91945-564c-4ace-bb53-77150b107b41"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eaa12b68-16e4-4231-8b3c-10991027b469"}}}}, {"uuid": "a6ace854-9e20-4e34-a8ac-01f0302fcf6d", "name": "43c90ffd-1e6d-4ea6-aada-9d1a91bf8efe_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.363394523648868, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.5065914416455906, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "065f8d03-acd9-4aef-bf32-ec679cb85d63", "name": "a3ed8f2e-1670-44f9-8eae-31627a7f6e4b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a6ace854-9e20-4e34-a8ac-01f0302fcf6d"}}}]}, {"uuid": "0255150b-1a31-4522-8e00-e52cf5303f41", "name": "load_p1rlv536_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2ea78a8-b9c5-4760-b153-51b45565069e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "065f8d03-acd9-4aef-bf32-ec679cb85d63"}}}}, {"uuid": "5c656de1-ba9d-489b-ae10-b9b2cc439b5b", "name": "7e21c187-648b-45f5-8192-47fa6cd85fdf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.363394523648868, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.5065914416455906, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9103a65d-75a8-4b3c-b9ff-c75118cc02df", "name": "daf7cc08-4973-45f6-9c31-f9245ec99d6f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5c656de1-ba9d-489b-ae10-b9b2cc439b5b"}}}]}, {"uuid": "c2ee4201-1d4a-4e30-aacf-9278043885fc", "name": "load_p1rlv536_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2ea78a8-b9c5-4760-b153-51b45565069e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9103a65d-75a8-4b3c-b9ff-c75118cc02df"}}}}, {"uuid": "0ca2ed02-9ad9-4b9d-9119-90d61a8f442c", "name": "d67ef7d5-94b0-4f8e-ab83-8624470c1e4e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.116603176693932, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3416039415731394, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e5767b74-2bf6-4ae0-acb8-f7db26c54e9d", "name": "fb42b4a2-841e-4022-a801-c14a2c0472a3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0ca2ed02-9ad9-4b9d-9119-90d61a8f442c"}}}]}, {"uuid": "72b2862e-3870-432b-ace8-81c712ed9d0d", "name": "load_p1rlv537_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9f2dfc9e-0b72-4465-b46a-d4e2a7a08f64"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e5767b74-2bf6-4ae0-acb8-f7db26c54e9d"}}}}, {"uuid": "23162cba-e334-4c24-8a3d-fe1db1c34086", "name": "9c924ee9-38fd-4520-9b2c-6cb755f2ff7e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.116603176693932, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3416039415731394, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "887a9b49-4c57-496a-900a-ca04d7b633c4", "name": "e54f1c45-bd2d-438b-8427-ecfd4fe61f5f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "23162cba-e334-4c24-8a3d-fe1db1c34086"}}}]}, {"uuid": "cc0d6925-8787-4d18-8616-fbf30f6c7a5a", "name": "load_p1rlv537_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9f2dfc9e-0b72-4465-b46a-d4e2a7a08f64"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "887a9b49-4c57-496a-900a-ca04d7b633c4"}}}}, {"uuid": "f479d563-a28f-487c-aba5-5b707ed429ad", "name": "ca60cbb9-048c-4e48-890a-7f6fbbe22e57_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6767459289154356, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5300288174067083, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "15daf489-d6f4-44b4-8486-5ef3e50832ad", "name": "0e758f65-c58a-4d6f-8f86-94670c97cafc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f479d563-a28f-487c-aba5-5b707ed429ad"}}}]}, {"uuid": "439e259e-fd7b-4f6b-87d9-7e0edc642f0a", "name": "load_p1rlv588_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75628d41-a82d-4425-8aa2-9f377c771a4c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "15daf489-d6f4-44b4-8486-5ef3e50832ad"}}}}, {"uuid": "0fbd767f-ece8-4ab5-ac8f-0e3782a2ad01", "name": "24e1c251-d056-4a30-bc82-aa0495716368_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6767459289154356, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5300288174067083, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a3aa04d-8ef0-49a2-ae2e-c077b3917d37", "name": "94f5cf50-5df4-4976-a4e9-e867721ce02b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0fbd767f-ece8-4ab5-ac8f-0e3782a2ad01"}}}]}, {"uuid": "3273b0f0-7ce3-4acf-ac66-549e19fb080b", "name": "load_p1rlv588_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75628d41-a82d-4425-8aa2-9f377c771a4c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0a3aa04d-8ef0-49a2-ae2e-c077b3917d37"}}}}, {"uuid": "5454428d-4b56-4c90-907c-d2e9f84a7cfd", "name": "c60191c3-09f3-420e-8bb1-27609dba5428_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8288850538480296, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31695217299610473, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "656c4d3a-9a01-4536-a830-009e8a1c604a", "name": "49d4c517-8c33-4849-91f9-ddd6d490ca31", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5454428d-4b56-4c90-907c-d2e9f84a7cfd"}}}]}, {"uuid": "6c13ec2c-acf6-4759-8425-ea576533c0dc", "name": "load_p1rlv589_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a1c60be-f1a1-48d6-b396-4cca6d8c4e62"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "656c4d3a-9a01-4536-a830-009e8a1c604a"}}}}, {"uuid": "ec435995-213c-4d1e-9b6b-df574871d42d", "name": "40b103c5-1c82-4aee-970a-e97519bb40a7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8288850538480296, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31695217299610473, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "faf98a77-df0a-477b-9f0f-6c363b5d2123", "name": "d7863b9b-b520-4877-b8bb-f9ef347b1395", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ec435995-213c-4d1e-9b6b-df574871d42d"}}}]}, {"uuid": "5c7d4191-8a3a-41c7-96f9-0bf89787fb72", "name": "load_p1rlv589_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a1c60be-f1a1-48d6-b396-4cca6d8c4e62"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "faf98a77-df0a-477b-9f0f-6c363b5d2123"}}}}, {"uuid": "3beaa7fe-e44e-44c0-8550-d2dae7715ac7", "name": "790e25fc-e449-4b27-ac54-1c45374122f5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.696455257947775, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.26943121901999684, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9a4ea290-c792-4ca9-8131-861a4fe68281", "name": "7302f3af-6f22-4f34-8c25-ece13254bfd8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3beaa7fe-e44e-44c0-8550-d2dae7715ac7"}}}]}, {"uuid": "7af173ca-da42-4ca5-b075-bdda3d3b89b8", "name": "load_p1rlv590_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81ce208e-7244-418a-9867-b55b95ba0716"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9a4ea290-c792-4ca9-8131-861a4fe68281"}}}}, {"uuid": "a849ebcb-fdce-4c2e-9923-7e6dd4671f26", "name": "aa41234b-e5d6-46df-bfa3-f936d97f3b39_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.696455257947775, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.26943121901999684, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "63e9d6da-3858-4395-859b-5e91c85df054", "name": "2aba41cc-ff74-4ae2-8f3c-83d6584d1cdc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a849ebcb-fdce-4c2e-9923-7e6dd4671f26"}}}]}, {"uuid": "8821a99d-8519-45d6-8371-606244795fe4", "name": "load_p1rlv590_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81ce208e-7244-418a-9867-b55b95ba0716"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "63e9d6da-3858-4395-859b-5e91c85df054"}}}}, {"uuid": "e23c6472-6af6-4c1e-932d-82123696e1c7", "name": "9f2ff2ae-cb4c-4205-874f-eb54aa1f32c9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.201469129926609, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0819349187657892, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6ed963ec-d8f3-47a6-b9ef-1624186b18da", "name": "ed5a8730-72c7-42e7-accc-d7028a2d3820", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e23c6472-6af6-4c1e-932d-82123696e1c7"}}}]}, {"uuid": "cbc47274-6a9a-4433-b62e-9b0e76aa835d", "name": "load_p1rlv657_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e58890e-e6ce-4dda-91c0-5ccfdb5c420d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6ed963ec-d8f3-47a6-b9ef-1624186b18da"}}}}, {"uuid": "65b73121-cc40-40d2-bddb-6b806f9c9c6d", "name": "eb47a207-eec2-4443-8388-f1644c875527_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.201469129926609, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0819349187657892, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d759b4b2-abec-4247-9cdb-3a0eafa5c792", "name": "d19accf4-becc-4df4-b130-93ba848b0f46", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "65b73121-cc40-40d2-bddb-6b806f9c9c6d"}}}]}, {"uuid": "abab5b2f-4b1c-487f-9c44-2e6d023e44f8", "name": "load_p1rlv657_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e58890e-e6ce-4dda-91c0-5ccfdb5c420d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d759b4b2-abec-4247-9cdb-3a0eafa5c792"}}}}, {"uuid": "0adb4448-1fc9-4ca0-aaab-5784dc663298", "name": "03cf9e18-143d-46fa-b23a-2636cc112a71_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1427818095792333, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033588044558321, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7ecc59f0-062e-4ed5-8351-d96ea59cb8f0", "name": "2961c013-da08-4474-ac53-1bd736e3b497", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0adb4448-1fc9-4ca0-aaab-5784dc663298"}}}]}, {"uuid": "997296ac-dae1-4e24-91df-20a54b89fd04", "name": "load_p1rlv660_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15751ee2-6783-472f-ad57-ec978234fec4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7ecc59f0-062e-4ed5-8351-d96ea59cb8f0"}}}}, {"uuid": "930ffc53-d75a-41a4-8954-7b674d2f4af9", "name": "107ff0d1-7f72-41fb-ae12-5f0d4767108e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1427818095792333, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033588044558321, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "67c3a1d4-fc5a-4a0c-8e6e-b8450ea2d0db", "name": "25c8bf86-cc0a-427c-9964-cf4625f8a763", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "930ffc53-d75a-41a4-8954-7b674d2f4af9"}}}]}, {"uuid": "acb5b681-5b80-45dc-b349-c71b951c0130", "name": "load_p1rlv660_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15751ee2-6783-472f-ad57-ec978234fec4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "67c3a1d4-fc5a-4a0c-8e6e-b8450ea2d0db"}}}}, {"uuid": "73e32d34-7add-44a2-ad8b-44f65d59b253", "name": "78b53566-5bcd-4798-971c-7e9eda98137f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7935386970404408, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "353c28a6-2d33-4062-9cb5-cdaa5812041f", "name": "7868a77f-5078-42de-8c51-9bfb7ac7066e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "73e32d34-7add-44a2-ad8b-44f65d59b253"}}}]}, {"uuid": "00ee95d8-2b16-4183-adf1-e90910dbd1d1", "name": "load_p1rlv672_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb25bf05-ce7f-405a-8c17-fd166748f7d3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "353c28a6-2d33-4062-9cb5-cdaa5812041f"}}}}, {"uuid": "454c48ee-7a4d-4380-8af5-b777bf2faf5a", "name": "be5dac99-946a-4df5-8952-d1147d3fdd3b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7935386970404408, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "67770ecd-bc51-43f6-a467-df322344d97f", "name": "9b7192a2-8782-4dd6-925b-2fd55240b789", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "454c48ee-7a4d-4380-8af5-b777bf2faf5a"}}}]}, {"uuid": "2539222d-42f5-4f63-97e7-8c79633002cd", "name": "load_p1rlv672_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb25bf05-ce7f-405a-8c17-fd166748f7d3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "67770ecd-bc51-43f6-a467-df322344d97f"}}}}, {"uuid": "8a2565fc-2d10-411c-8b58-83ef9b8ba177", "name": "623d7d87-a72d-40d7-b15b-85211aeb8f62_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6873327290171372, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.38872845841522474, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "943ccbbf-545d-4d49-9fd9-da21451999ea", "name": "a0ff9f0f-f8db-4490-bb2a-c6659b925e09", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a2565fc-2d10-411c-8b58-83ef9b8ba177"}}}]}, {"uuid": "c22f9cd1-7aeb-4504-8fde-e07798bc325c", "name": "load_p1rlv673_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31d3267c-7020-4660-9a0b-49cd9d94a5d0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "943ccbbf-545d-4d49-9fd9-da21451999ea"}}}}, {"uuid": "52af43a7-2e10-476d-8f79-b64cc7623bfb", "name": "afc205a7-9f2d-4fd7-b294-a779ae841c7c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6873327290171372, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.38872845841522474, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "45401b66-ff96-4eea-9815-3750c71f19fe", "name": "2210476a-d427-48ac-aade-1e24916762a3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "52af43a7-2e10-476d-8f79-b64cc7623bfb"}}}]}, {"uuid": "56dd86e6-118f-4e7b-be9e-80e878193209", "name": "load_p1rlv673_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31d3267c-7020-4660-9a0b-49cd9d94a5d0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "45401b66-ff96-4eea-9815-3750c71f19fe"}}}}, {"uuid": "f23b238e-c41b-443f-976a-5439245d3616", "name": "282b9f7a-558f-4bae-be6b-4b852c874a38_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.629144238694082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9654448182756213, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1669e9ce-f614-4955-a87e-dd5775809296", "name": "465f7b3a-9ee2-4371-a88c-221f1773518a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f23b238e-c41b-443f-976a-5439245d3616"}}}]}, {"uuid": "bbeff04d-d4e6-49a0-8728-228f48fafd80", "name": "load_p1rlv674_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "449992d6-a91b-40ea-9792-5166a5f2c849"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1669e9ce-f614-4955-a87e-dd5775809296"}}}}, {"uuid": "697cc389-c07a-4dc3-86ea-c2559e23b687", "name": "413ebfd2-b99c-47df-90c6-dc5d1d8ea19e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.629144238694082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9654448182756213, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d1530a61-86d4-4018-bd0f-dcb9c860acb7", "name": "f8554fd1-2ba0-4cc7-b987-61922233324b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "697cc389-c07a-4dc3-86ea-c2559e23b687"}}}]}, {"uuid": "2a50a4d9-31db-4326-8b24-51ddf0b96e18", "name": "load_p1rlv674_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "449992d6-a91b-40ea-9792-5166a5f2c849"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d1530a61-86d4-4018-bd0f-dcb9c860acb7"}}}}, {"uuid": "e4d98caf-81e1-4441-b631-5c089e5d1282", "name": "a82f2924-5745-42c2-b066-45d94daed215_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2527429497469504, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5005012096685874, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1df1739a-2fb0-45e1-9b23-8363bbc5125c", "name": "df7aed15-398f-410c-829d-3b9905adf57a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e4d98caf-81e1-4441-b631-5c089e5d1282"}}}]}, {"uuid": "ede5311a-13dd-4156-8805-07596031707f", "name": "load_p1rlv716_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "93069f0f-fce7-47cd-b7b3-77e861f59573"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1df1739a-2fb0-45e1-9b23-8363bbc5125c"}}}}, {"uuid": "58392726-d0ac-4fe6-9dba-23581fc55985", "name": "f9fbe0ae-67ea-4039-9754-89cd2da347b0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2527429497469504, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5005012096685874, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2b89be86-388c-400b-b82c-a5e26babb039", "name": "acacb8f3-dd51-4dc1-9b99-7c14d0cd1ba5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58392726-d0ac-4fe6-9dba-23581fc55985"}}}]}, {"uuid": "1f87880a-e02f-4c82-a483-7f3d08ad74f0", "name": "load_p1rlv716_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "93069f0f-fce7-47cd-b7b3-77e861f59573"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2b89be86-388c-400b-b82c-a5e26babb039"}}}}, {"uuid": "bf496c73-e70e-423a-96b1-fec14de1cae3", "name": "f310019d-dc68-401e-a608-8f9873831b88_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.916354724025409, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9016755043678467, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ee026057-b475-41b4-9779-c9e655f595e4", "name": "55e3eda6-0059-4f6f-99e1-fd657134df3d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bf496c73-e70e-423a-96b1-fec14de1cae3"}}}]}, {"uuid": "bfa2a69f-a518-48d9-b301-9ecedffbc7df", "name": "load_p1rlv717_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd8fd159-f747-4ee4-a426-787f4eef4b42"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ee026057-b475-41b4-9779-c9e655f595e4"}}}}, {"uuid": "28596690-1a72-4eb3-88be-d63b33a6aa7b", "name": "e4e5404d-c770-4339-b715-c92a48adccff_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.916354724025409, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9016755043678467, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "38f4e1b1-3d21-4665-9b25-7d4717c4cf7d", "name": "588b544f-3513-4e91-b239-0cb86d9d9ab0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "28596690-1a72-4eb3-88be-d63b33a6aa7b"}}}]}, {"uuid": "afeb6c0e-ac4d-455f-aaf8-562288cbf02c", "name": "load_p1rlv717_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd8fd159-f747-4ee4-a426-787f4eef4b42"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "38f4e1b1-3d21-4665-9b25-7d4717c4cf7d"}}}}, {"uuid": "68031fd5-2533-4e56-9d65-f86eb933be4f", "name": "6db53d39-c949-4671-af40-bb2a932b8663_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.786120494572624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2344198860247402, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f056302a-9feb-4ed2-99b8-d266c61b39a6", "name": "af07bc93-3dcf-4220-8b1c-ecada1320a11", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "68031fd5-2533-4e56-9d65-f86eb933be4f"}}}]}, {"uuid": "977afcb1-5009-4ac4-b614-e3ca9da3a132", "name": "load_p1rlv718_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4a1453b-98a3-4c2d-8ac2-c8b2ab1bfa4f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f056302a-9feb-4ed2-99b8-d266c61b39a6"}}}}, {"uuid": "3585aea3-3794-4904-9bea-6f6577ba20d1", "name": "4ebb5e28-2f63-4b4f-b4b3-1e3f25027fba_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.786120494572624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2344198860247402, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f395d072-a839-4ac6-b22a-ba64f15a695f", "name": "dc5bb47e-ac2d-4fd7-9799-2d2244310396", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3585aea3-3794-4904-9bea-6f6577ba20d1"}}}]}, {"uuid": "acd07cca-61e9-4d04-a311-705836ab8e65", "name": "load_p1rlv718_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4a1453b-98a3-4c2d-8ac2-c8b2ab1bfa4f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f395d072-a839-4ac6-b22a-ba64f15a695f"}}}}, {"uuid": "b18f4b09-ed17-44bc-91ed-0c1ab5fd29f0", "name": "352ee402-7303-457c-8250-6c8740280031_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.872791085416893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.761492956317497, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6c62ae6d-d04e-4992-ae3f-25bd74f7a2f5", "name": "5b7571da-3ce0-486f-b952-4b3fea385372", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b18f4b09-ed17-44bc-91ed-0c1ab5fd29f0"}}}]}, {"uuid": "79c3a6fa-cd50-451c-96b7-2b35828c1130", "name": "load_p1rlv719_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3153167-8b4c-40e4-abb7-3bdef86950c3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6c62ae6d-d04e-4992-ae3f-25bd74f7a2f5"}}}}, {"uuid": "446dea59-a20d-4230-9868-466622a8596f", "name": "49bc3b2c-a430-418b-ae9b-1dbfe1acf7da_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.872791085416893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.761492956317497, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ed8a7b8a-0b5f-4835-96b4-03b2e8233240", "name": "022113f8-efad-4ccb-b324-6be956eedc22", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "446dea59-a20d-4230-9868-466622a8596f"}}}]}, {"uuid": "5d798181-b869-42ea-ad5c-4ffb250a43c6", "name": "load_p1rlv719_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3153167-8b4c-40e4-abb7-3bdef86950c3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ed8a7b8a-0b5f-4835-96b4-03b2e8233240"}}}}, {"uuid": "78dca5a5-2c84-4ac1-b8e3-d85046b179ac", "name": "4885aac2-d383-42d3-b012-fa12ac7c001b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.000000644073754, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1655557120603839, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b7861d22-0711-4175-8380-6949e323537c", "name": "c240c5ca-e0d0-49f6-89b3-f39f936d3cf4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "78dca5a5-2c84-4ac1-b8e3-d85046b179ac"}}}]}, {"uuid": "ae80bdbe-4444-4eac-97fb-51bcb6cc2d84", "name": "load_p1rlv720_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdbc11b7-5abf-4ff8-8d26-53faf4b1f3f5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b7861d22-0711-4175-8380-6949e323537c"}}}}, {"uuid": "1d863231-f17e-4b90-b3c8-a71a7ff0d81e", "name": "5428a001-da2b-48f0-8ac3-13506a749c4a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.000000644073754, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1655557120603839, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f0bdde55-7be0-4905-8777-cd2aff83f410", "name": "4154317d-cfc9-4a54-9941-94974a1c7930", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1d863231-f17e-4b90-b3c8-a71a7ff0d81e"}}}]}, {"uuid": "0d1c5f25-f550-471e-a519-97e3204a3ce9", "name": "load_p1rlv720_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdbc11b7-5abf-4ff8-8d26-53faf4b1f3f5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f0bdde55-7be0-4905-8777-cd2aff83f410"}}}}, {"uuid": "eb054f98-f757-4381-a754-386a4f692c7e", "name": "cd70e24d-36fb-4c38-9091-a607a7510221_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5041010955030301, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21577690333785765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1769bd12-ea2f-4e78-b9b4-d466df50ed95", "name": "e3a31a47-8ce6-4377-b101-b708d47ee0c4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eb054f98-f757-4381-a754-386a4f692c7e"}}}]}, {"uuid": "90a60c4d-b19b-45e9-88a5-f37644403db8", "name": "load_p1rlv721_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf12b67c-4df5-4dcb-a2e2-6ae2d0f82e65"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1769bd12-ea2f-4e78-b9b4-d466df50ed95"}}}}, {"uuid": "e6ccadcb-551c-4fce-9af8-b2c1ce35e751", "name": "adb54d5f-cca1-41b2-b7f0-30b4ca644bd3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5041010955030301, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21577690333785765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6d569f9f-5b10-4009-a8e9-d27ed169cb1c", "name": "f2aed3a1-839d-4ccd-b083-5939d16814d8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e6ccadcb-551c-4fce-9af8-b2c1ce35e751"}}}]}, {"uuid": "36af70ed-991f-4f4d-a0c6-02bfeb5237a9", "name": "load_p1rlv721_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf12b67c-4df5-4dcb-a2e2-6ae2d0f82e65"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6d569f9f-5b10-4009-a8e9-d27ed169cb1c"}}}}, {"uuid": "5f3616e6-0f56-49dc-962f-5a9371bb503e", "name": "be256f82-a4ca-4c22-aa1c-f53f933a408d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6733980323267108, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22626974414284334, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "900a87a8-5526-4eb4-b5a0-979080a61198", "name": "f62b6131-8890-4ca4-ac96-d20f59ace51b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5f3616e6-0f56-49dc-962f-5a9371bb503e"}}}]}, {"uuid": "ce2e7d49-8d13-4420-86ed-e25fa9f409cb", "name": "load_p1rlv722_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b7c6c65-e18c-4e79-b419-8894deb0d345"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "900a87a8-5526-4eb4-b5a0-979080a61198"}}}}, {"uuid": "91a1f911-9c6e-4f9d-b57a-24870fb2799a", "name": "3ced0a9a-c4e6-4a5a-ac86-9fed36368435_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6733980323267108, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22626974414284334, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8c040eae-447e-41cd-98e3-95b28f9c3636", "name": "9c50eea9-4cd9-45ca-9f4b-53d8c330a52f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "91a1f911-9c6e-4f9d-b57a-24870fb2799a"}}}]}, {"uuid": "af969afc-6753-4848-a059-1b3dd13285ac", "name": "load_p1rlv722_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b7c6c65-e18c-4e79-b419-8894deb0d345"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8c040eae-447e-41cd-98e3-95b28f9c3636"}}}}, {"uuid": "d0e3b089-c79e-4876-95b1-fb7d504380c2", "name": "4948e182-fabc-4164-82d3-ddf56e545b76_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2596055778412756, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4460523908595607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "120e19ed-92c5-4d00-b8b3-c9761ba75852", "name": "a7cc84eb-7b9c-4b97-a044-1f3f2bfadd43", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d0e3b089-c79e-4876-95b1-fb7d504380c2"}}}]}, {"uuid": "cc7beee9-ae31-4720-b679-66236113c044", "name": "load_p1rlv723_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7551be44-a4ca-4edb-b823-6495d163201e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "120e19ed-92c5-4d00-b8b3-c9761ba75852"}}}}, {"uuid": "f56ecadc-4862-4e7b-8afa-2d10acd0e581", "name": "0fde8a58-763b-43d1-93d1-4de9b34f2660_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2596055778412756, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4460523908595607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e82878f4-7239-4c3a-8d86-512ea4be2428", "name": "0b72b0d5-3710-48c1-8165-3fc647a05336", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f56ecadc-4862-4e7b-8afa-2d10acd0e581"}}}]}, {"uuid": "c03cf62f-3808-464a-b0b0-216bc94398b6", "name": "load_p1rlv723_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7551be44-a4ca-4edb-b823-6495d163201e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e82878f4-7239-4c3a-8d86-512ea4be2428"}}}}, {"uuid": "206ccb98-6132-4ee4-9c61-598990f1ef36", "name": "414d01c4-24ab-4828-bed6-9792187e017e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.794005533851084, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6855099409421886, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b839b6ba-2d40-44a3-8a83-1b9c240ff553", "name": "fe0822bd-009c-49aa-8c17-d6519e77523a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "206ccb98-6132-4ee4-9c61-598990f1ef36"}}}]}, {"uuid": "cda0e6a3-6816-4724-9d32-66cf642a638b", "name": "load_p1rlv724_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3658479-7369-4bd9-be54-e7768c93a808"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b839b6ba-2d40-44a3-8a83-1b9c240ff553"}}}}, {"uuid": "ab4a0044-8726-4027-8728-cab4f9c28832", "name": "d9befc77-f563-4e77-8348-4a35a3f6204c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.794005533851084, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6855099409421886, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5013d830-da3a-4cc4-bae0-872873f72f9d", "name": "3179e716-63ce-4f4e-84f7-a115095ff69b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ab4a0044-8726-4027-8728-cab4f9c28832"}}}]}, {"uuid": "32b32edf-0faa-4b81-8ce6-dc1f54bb4230", "name": "load_p1rlv724_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3658479-7369-4bd9-be54-e7768c93a808"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5013d830-da3a-4cc4-bae0-872873f72f9d"}}}}, {"uuid": "b17267ee-47c5-411a-a31b-ebe7f1237538", "name": "8ab8e5d0-1269-44e5-8fbe-90c56e6bea92_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7997673490012955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.772957044307952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "63ea1069-71be-457d-9839-65489224aa34", "name": "55100585-da78-4e58-bb3e-7b5689090e75", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b17267ee-47c5-411a-a31b-ebe7f1237538"}}}]}, {"uuid": "18c72770-ada5-451b-a875-7af3a4e7e5e4", "name": "load_p1rlv725_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2bcbabc-a7fc-4230-8ec1-b6050af9cf58"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "63ea1069-71be-457d-9839-65489224aa34"}}}}, {"uuid": "202490d4-2e13-4030-9563-cd2d19bd3793", "name": "5d799024-2182-434b-a3aa-eb41f7d2d023_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7997673490012955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.772957044307952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2eba0569-eddf-44d2-b873-54968c0ff842", "name": "fc05ed22-e71c-46e6-94df-0433df5a2457", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "202490d4-2e13-4030-9563-cd2d19bd3793"}}}]}, {"uuid": "f7902d74-d4ed-43ba-af65-9db169a096e8", "name": "load_p1rlv725_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2bcbabc-a7fc-4230-8ec1-b6050af9cf58"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2eba0569-eddf-44d2-b873-54968c0ff842"}}}}, {"uuid": "35be8c28-4603-4c6d-b4bd-a972a67044dc", "name": "4020d951-95a0-453f-b69f-2cd0350929b1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.762685564172624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.7175951697927787, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4fefaa1d-8570-4fdd-908d-f3877c473c07", "name": "394b95f6-b12a-4cc1-98de-303c5877fe0a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "35be8c28-4603-4c6d-b4bd-a972a67044dc"}}}]}, {"uuid": "0b358c72-6f60-48ae-8c2c-3c786b5a52fc", "name": "load_p1rlv726_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fdcbc55-681f-4fe5-8142-4945b25f6fef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4fefaa1d-8570-4fdd-908d-f3877c473c07"}}}}, {"uuid": "654ab3ed-1580-4c7a-a3db-4cd47906bb85", "name": "aacb3ee5-917c-4517-b756-44a73b1213d8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.762685564172624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.7175951697927787, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2e4cb72a-c229-4b25-b5c8-012e536eb05a", "name": "d39ceafe-765a-4fa3-bbb0-01872c9a5dc1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "654ab3ed-1580-4c7a-a3db-4cd47906bb85"}}}]}, {"uuid": "bd703703-bee0-41ea-9c5a-2bb2e1a77c77", "name": "load_p1rlv726_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fdcbc55-681f-4fe5-8142-4945b25f6fef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2e4cb72a-c229-4b25-b5c8-012e536eb05a"}}}}, {"uuid": "c9b17eaa-a404-4df1-aa43-fad0d049acac", "name": "914c059f-404a-49d2-be3f-3a4bbfa166d8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.981510789736824, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31377757670385525, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2e07e5a2-10ac-4133-a440-a0264b5555a1", "name": "b7887293-b0cd-4eb6-9448-45496ea31cbc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9b17eaa-a404-4df1-aa43-fad0d049acac"}}}]}, {"uuid": "7a93df03-8bc9-4742-b9f2-132964907df8", "name": "load_p1rlv749_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80983704-a98f-46dc-a09f-700bd7df1a29"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2e07e5a2-10ac-4133-a440-a0264b5555a1"}}}}, {"uuid": "1ccee909-af72-488c-ac95-cf3da56f22d5", "name": "fa888314-932e-4416-ab8a-3efe94677372_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.981510789736824, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31377757670385525, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4465aaeb-7114-4a39-88d9-ae13308d7239", "name": "d2c1e38f-6d88-4622-a3c7-9e43fa043ade", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1ccee909-af72-488c-ac95-cf3da56f22d5"}}}]}, {"uuid": "1748effe-25e9-4eb7-bf52-0121f8ec8725", "name": "load_p1rlv749_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80983704-a98f-46dc-a09f-700bd7df1a29"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4465aaeb-7114-4a39-88d9-ae13308d7239"}}}}, {"uuid": "97595f54-fa68-4bc7-a5d8-08e42f71deb9", "name": "5a922f5f-0a3a-4a86-b0b2-2bd83a97c70e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3612560165719545, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7198526424662817, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2284f4af-57f8-481e-845b-620d59dd587c", "name": "25785f91-6b3b-4678-ab4f-a5c1c5582b2e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "97595f54-fa68-4bc7-a5d8-08e42f71deb9"}}}]}, {"uuid": "4068cc20-6387-452c-b2d9-f20698ada793", "name": "load_p1rlv756_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3c3b0fb-5a5d-439e-a350-b97ba0df41a0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2284f4af-57f8-481e-845b-620d59dd587c"}}}}, {"uuid": "6dfd623a-6445-4a09-814a-c64d2133b497", "name": "78e36fd2-0a28-4227-bc4a-c4a8a7015c3b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3612560165719545, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7198526424662817, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2f73c189-c676-4215-b467-dc29671c2291", "name": "757afc2b-5fc3-49df-86c7-eb3e0da98a49", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6dfd623a-6445-4a09-814a-c64d2133b497"}}}]}, {"uuid": "6ad9daeb-12ab-4094-8f0a-f1d464b428a0", "name": "load_p1rlv756_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3c3b0fb-5a5d-439e-a350-b97ba0df41a0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2f73c189-c676-4215-b467-dc29671c2291"}}}}, {"uuid": "095ab4d6-8a69-462d-a850-f0b13520dbc4", "name": "14aa8b69-3b5d-4b12-9027-e1f27c344633_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.910200682298975, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5555412020426419, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a53fa2df-1c44-4551-970d-eaf3bf4ff3aa", "name": "671c0fa0-40f7-43af-8879-e9ed849c7b38", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "095ab4d6-8a69-462d-a850-f0b13520dbc4"}}}]}, {"uuid": "49bfdc0b-b1f1-4793-a1ee-c23ebccfb7ca", "name": "load_p1rlv764_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e368704b-6c4b-4afb-a577-4b0d7a96dd65"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a53fa2df-1c44-4551-970d-eaf3bf4ff3aa"}}}}, {"uuid": "98e825f3-67b7-4c37-94e4-ba4cd44d1c77", "name": "75b95e6b-993e-49d1-beaf-05ad1485d9dc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.910200682298975, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5555412020426419, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ac754445-1442-4550-905e-8e707d74471b", "name": "cba8842f-933e-489e-addf-3b06dcb6b8f1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "98e825f3-67b7-4c37-94e4-ba4cd44d1c77"}}}]}, {"uuid": "76bba039-59f2-4f78-8883-71aa2de6a56f", "name": "load_p1rlv764_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e368704b-6c4b-4afb-a577-4b0d7a96dd65"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ac754445-1442-4550-905e-8e707d74471b"}}}}, {"uuid": "da122198-fdf4-4f17-91f4-a07f00b0635a", "name": "d2b79295-98d1-4ac5-9fd4-50f63968a697_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4856814769108864, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8267323554826451, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "981253cf-9ec0-46de-96c7-894d0ea481f3", "name": "14cc4b68-7bdb-4ee6-85d8-136e91f1acbc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "da122198-fdf4-4f17-91f4-a07f00b0635a"}}}]}, {"uuid": "bd077c4a-347f-469a-9666-a1ffd44e74e9", "name": "load_p1rlv766_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07381934-8e9b-4447-a330-e8af484331f1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "981253cf-9ec0-46de-96c7-894d0ea481f3"}}}}, {"uuid": "44b0c0d9-18c0-456c-badf-3f0150e3ff71", "name": "376debc5-4871-42ec-a45b-c7ca0f7641fb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4856814769108864, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8267323554826451, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "24537064-7722-4085-ae94-ad0a58eafd75", "name": "a38cdba4-704d-4fa8-ba52-cd2636dd6f24", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "44b0c0d9-18c0-456c-badf-3f0150e3ff71"}}}]}, {"uuid": "cb470b47-d7b1-400f-8605-511c302fd177", "name": "load_p1rlv766_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07381934-8e9b-4447-a330-e8af484331f1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "24537064-7722-4085-ae94-ad0a58eafd75"}}}}, {"uuid": "2d0835b7-8d42-4dbe-bab2-b7cf2bd0a3ce", "name": "c9a27d67-ee66-48b5-9c74-241a63a61769_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7083181921938193, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5666922324635131, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b009a683-06f5-412d-b28a-2d70d330b918", "name": "12fdd19f-c9c9-4712-87a7-0eb4cfeeea43", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2d0835b7-8d42-4dbe-bab2-b7cf2bd0a3ce"}}}]}, {"uuid": "af3c78f3-2c17-4189-920c-66419131c6f5", "name": "load_p1rlv775_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d00977fb-8d2a-44ca-aa9e-034894d6e280"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b009a683-06f5-412d-b28a-2d70d330b918"}}}}, {"uuid": "bfa66587-5224-4964-bf22-adc45a8102b5", "name": "efb56f1f-ea09-462e-bf7a-c0d3aef7d273_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7083181921938193, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5666922324635131, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "af7f6606-be0b-4ffb-9ad5-14dc2b7b129c", "name": "f4304dad-8b4c-4aec-b5ba-69374fbc18a6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bfa66587-5224-4964-bf22-adc45a8102b5"}}}]}, {"uuid": "e98e2389-7cf7-4dd2-92bd-be1be91c4a06", "name": "load_p1rlv775_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d00977fb-8d2a-44ca-aa9e-034894d6e280"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "af7f6606-be0b-4ffb-9ad5-14dc2b7b129c"}}}}, {"uuid": "c647da92-87b1-48a3-92c2-188de6a9533d", "name": "7da23661-24f7-4c1d-84c2-5e0d59552fad_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.779437116944347, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0510023138100544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bba4366b-4b54-4a75-a4b3-4ba63f4de749", "name": "91699525-1af6-4e00-b7c7-5cd4d14db0dd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c647da92-87b1-48a3-92c2-188de6a9533d"}}}]}, {"uuid": "bf3f6187-ae8e-4b4a-bac1-260d3b7c7bba", "name": "load_p1rlv776_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c5b1f75-47c0-45c3-9ef3-f97a445b242e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bba4366b-4b54-4a75-a4b3-4ba63f4de749"}}}}, {"uuid": "ed7c1fbd-90bd-42f8-bdda-65b54bacce7c", "name": "0b724cdf-7e23-40d8-85ef-44b2fef77f36_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.779437116944347, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0510023138100544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "68bafba1-5b2b-40db-b17e-442cca8e5d82", "name": "c9bae9e4-9c6d-4106-81be-52b260b3b36e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ed7c1fbd-90bd-42f8-bdda-65b54bacce7c"}}}]}, {"uuid": "8f8d4df1-5a48-4c4c-b74b-f1c95de4cc03", "name": "load_p1rlv776_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c5b1f75-47c0-45c3-9ef3-f97a445b242e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "68bafba1-5b2b-40db-b17e-442cca8e5d82"}}}}, {"uuid": "0df6d500-fb5a-4499-a196-31a12b23a034", "name": "be8c7f3b-9a68-4c98-9632-9cdbf579b8cb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3483029031483318, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6505451661884267, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b0a276b7-d3fc-4c8f-9da5-216c398babf3", "name": "334fc552-b885-4faa-bb7e-c1332260f2e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0df6d500-fb5a-4499-a196-31a12b23a034"}}}]}, {"uuid": "da976a87-52f4-48fc-b48d-c87ee7f367c3", "name": "load_p1rlv777_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fb1fca8-7985-4356-a8de-7433fef7a454"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b0a276b7-d3fc-4c8f-9da5-216c398babf3"}}}}, {"uuid": "f184f240-c154-4d08-99f3-6d35887d55fc", "name": "a20f9e8b-6285-4a23-bf3c-811d440ca941_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3483029031483318, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6505451661884267, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8fd141ec-66ef-48ae-b92c-051f229c57bd", "name": "88f79e12-1637-4b3c-84a6-497f9c34b51c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f184f240-c154-4d08-99f3-6d35887d55fc"}}}]}, {"uuid": "88825692-476f-466b-852c-5593f1a76bd5", "name": "load_p1rlv777_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fb1fca8-7985-4356-a8de-7433fef7a454"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8fd141ec-66ef-48ae-b92c-051f229c57bd"}}}}, {"uuid": "e3d3a257-3499-4ef3-a6fb-094615787127", "name": "58a200ee-cf6d-4ebd-8eee-13d37cba4efe_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.993849790823018, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8230403105677124, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dbc24d2f-ac5a-4014-9727-f3022d456fe8", "name": "4d093c92-29a0-4276-b2aa-0fc8f4ea3b6d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e3d3a257-3499-4ef3-a6fb-094615787127"}}}]}, {"uuid": "cf15fdf4-d3ca-4b4f-8331-3cfee831711f", "name": "load_p1rlv778_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80d58665-ee8a-4f4e-a906-dc15aa3d8c6f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dbc24d2f-ac5a-4014-9727-f3022d456fe8"}}}}, {"uuid": "ad44b362-b8d0-43f7-88fa-5e95294fc979", "name": "83ad46c7-97e5-41bc-a258-e129c9919c7d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.993849790823018, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8230403105677124, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "af72f8ad-1709-4aa0-bd4f-a57fe996c2b8", "name": "a4c6f312-dfb4-4684-90b7-89d96afcd6e1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ad44b362-b8d0-43f7-88fa-5e95294fc979"}}}]}, {"uuid": "c1643d04-ee94-4c42-a3fa-5a9649da51c2", "name": "load_p1rlv778_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80d58665-ee8a-4f4e-a906-dc15aa3d8c6f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "af72f8ad-1709-4aa0-bd4f-a57fe996c2b8"}}}}, {"uuid": "8fda77fb-2ca6-4aae-833e-2dc48e283d3a", "name": "8f978ad7-6b29-4136-bb49-a260293e3694_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9928270585646484, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0482885249865175, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "be510307-835d-455c-a22a-907e1c4aaf34", "name": "a4e10a40-6b35-4702-b2ef-dff0376c1927", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8fda77fb-2ca6-4aae-833e-2dc48e283d3a"}}}]}, {"uuid": "bd460ab7-6f33-4ad8-bab9-c7975ca760fe", "name": "load_p1rlv779_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fbc761bf-480c-465c-9479-279832c50bc2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "be510307-835d-455c-a22a-907e1c4aaf34"}}}}, {"uuid": "757268af-82cf-4c04-8286-0ce4dfa4b093", "name": "3ee4a450-9481-4eb5-b237-5c5a878e489a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9928270585646484, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0482885249865175, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d89ab889-d4db-4be6-9a90-26f73ba46828", "name": "b35d9fbe-013c-4a1c-83b9-4ab26d855305", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "757268af-82cf-4c04-8286-0ce4dfa4b093"}}}]}, {"uuid": "95c38f40-9c71-4894-8b76-b5299a47976e", "name": "load_p1rlv779_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fbc761bf-480c-465c-9479-279832c50bc2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d89ab889-d4db-4be6-9a90-26f73ba46828"}}}}, {"uuid": "de388c37-805e-46eb-be1f-9964021fb441", "name": "6eb3ddcf-b9b7-46c4-b045-4a3c23614f63_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1813646779377422, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20173832232537287, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7747797d-7399-4cfd-94fb-22f3f4208b34", "name": "cd15d90f-9046-4e94-80cc-c53c23cbcc2d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "de388c37-805e-46eb-be1f-9964021fb441"}}}]}, {"uuid": "e1ef1997-11c2-4bde-9614-10e1366bbfa7", "name": "load_p1rlv780_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20dcf67f-f04f-498a-830d-557ba7b4d867"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7747797d-7399-4cfd-94fb-22f3f4208b34"}}}}, {"uuid": "1d52a042-3b51-466c-b0b9-9793f90674f1", "name": "c6cc7966-7cb6-477f-b0aa-90853888976c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1813646779377422, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20173832232537287, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fb5b0f15-a6a3-4798-9359-04c664a0b337", "name": "de37e0df-b3dc-4372-8ca5-780e264ad2dc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1d52a042-3b51-466c-b0b9-9793f90674f1"}}}]}, {"uuid": "eaefd462-04ca-4b42-9951-de5390cfad14", "name": "load_p1rlv780_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20dcf67f-f04f-498a-830d-557ba7b4d867"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fb5b0f15-a6a3-4798-9359-04c664a0b337"}}}}, {"uuid": "df814907-32b4-490b-85d9-6989f1b2c207", "name": "07d5c973-7b09-4ca3-a5f4-762245e9177f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.774034588817963, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.005441618856208, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6ddcad46-046e-4970-bf6c-38a406e4c1a4", "name": "92d1d692-2e0d-4fc2-88ab-4c4eb635fa55", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "df814907-32b4-490b-85d9-6989f1b2c207"}}}]}, {"uuid": "1de06a56-a8a4-480a-a591-c39f83bf866b", "name": "load_p1rlv781_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98c5ba15-a339-478a-a79f-9298fab16a54"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6ddcad46-046e-4970-bf6c-38a406e4c1a4"}}}}, {"uuid": "ae008260-0220-4b43-bb09-b7a4db443cd6", "name": "9e31d366-716f-40d7-b4b5-357d54d0210a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.774034588817963, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.005441618856208, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f9734d7e-7513-4ce5-a13d-dbc4a0bbddb0", "name": "f503e21e-f463-4a19-8165-e9b74dfdb2bf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ae008260-0220-4b43-bb09-b7a4db443cd6"}}}]}, {"uuid": "2788224b-ffa0-4a6d-a6cb-1f419fca2c75", "name": "load_p1rlv781_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98c5ba15-a339-478a-a79f-9298fab16a54"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f9734d7e-7513-4ce5-a13d-dbc4a0bbddb0"}}}}, {"uuid": "d0474588-6987-431b-b039-72a024c5dae3", "name": "ab458b61-6fdc-437e-81f1-1481b840cc6c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7457942211533133, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8784341351558463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8e6e17c4-cccb-448b-bc16-ddf2158f70eb", "name": "8d70e38a-f57a-492f-9eba-5eb3f9019373", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d0474588-6987-431b-b039-72a024c5dae3"}}}]}, {"uuid": "bdf2cf7b-27a6-44ac-bff7-46e9c4ca9478", "name": "load_p1rlv782_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78a4f54a-017a-41b0-85c8-b3e408c21c08"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8e6e17c4-cccb-448b-bc16-ddf2158f70eb"}}}}, {"uuid": "6c14eafc-a7e2-46ce-9633-4b0777173e5b", "name": "1a084ecc-2ae8-4b1f-89b3-57a1d6d523cb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7457942211533133, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8784341351558463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "99378bc7-2911-4588-b03d-343b24aff733", "name": "b06b5fa9-00fe-479c-9711-aa527b5edbb0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c14eafc-a7e2-46ce-9633-4b0777173e5b"}}}]}, {"uuid": "e354d758-9648-4666-9d70-b77f5f1f4737", "name": "load_p1rlv782_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78a4f54a-017a-41b0-85c8-b3e408c21c08"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "99378bc7-2911-4588-b03d-343b24aff733"}}}}, {"uuid": "b24be7a9-3b59-4dc6-9298-d2905610d3aa", "name": "67db29c6-ad14-4b02-ad74-5ad57266c59e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0085854932437286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7150296414254909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8b88af4f-60ed-40e2-b8bf-1abff861db1e", "name": "12db7d6d-fa2f-4fca-bb8b-337ae132b8d9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b24be7a9-3b59-4dc6-9298-d2905610d3aa"}}}]}, {"uuid": "aade8390-df77-43bb-aaa2-244c12fee2fa", "name": "load_p1rlv783_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d1a96d5-f971-4116-9642-769ef5b97e7c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8b88af4f-60ed-40e2-b8bf-1abff861db1e"}}}}, {"uuid": "d5a5cd6a-c6a5-4fc5-8189-3a3b37c9b27a", "name": "ca63e231-3b8d-41bf-ac0b-0063b1db375a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0085854932437286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7150296414254909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ed040046-fa14-42be-9b37-7f7367b7dd4c", "name": "03707f96-fecf-4a1a-90ac-9a69dad2f714", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d5a5cd6a-c6a5-4fc5-8189-3a3b37c9b27a"}}}]}, {"uuid": "d52c6675-0c5d-4f90-bbac-83a9d5e1fb0a", "name": "load_p1rlv783_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d1a96d5-f971-4116-9642-769ef5b97e7c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ed040046-fa14-42be-9b37-7f7367b7dd4c"}}}}, {"uuid": "619dcfdf-f040-45a9-85f7-1e3ef0ec179a", "name": "7eb8803a-c167-4382-a54b-b2af56d8c932_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.965154260277072, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307595255595673, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50a79a8f-7190-4a2d-9d6d-5523568e51f8", "name": "c2d95147-22cb-4130-980a-eab5c2c596d6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "619dcfdf-f040-45a9-85f7-1e3ef0ec179a"}}}]}, {"uuid": "80dfbff6-7bba-43d8-9d0e-4164c32441c6", "name": "load_p1rlv784_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2823b5b9-bcc3-4b30-9874-89dc33ec80d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50a79a8f-7190-4a2d-9d6d-5523568e51f8"}}}}, {"uuid": "deb8610a-ede2-4a10-9146-967487bff884", "name": "294b3492-4155-4b3e-9a69-ac3490d2a85d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.965154260277072, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307595255595673, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1aef9c37-bb70-4ff6-ba21-a0d54c639258", "name": "aef5eabe-1271-4dde-9863-73bfb164f73a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "deb8610a-ede2-4a10-9146-967487bff884"}}}]}, {"uuid": "913c5b60-19da-4ec3-b487-ec0578ce1904", "name": "load_p1rlv784_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2823b5b9-bcc3-4b30-9874-89dc33ec80d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1aef9c37-bb70-4ff6-ba21-a0d54c639258"}}}}, {"uuid": "c9e7b15c-61f7-4b86-90e4-bfc2aad74f55", "name": "7713e8c5-850d-43cb-a2c3-91f3834f43d7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.948680292874151, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.769988963438003, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "45345969-43ff-4427-b01b-d383cffda331", "name": "1790b739-e6c0-4648-b2ae-649d4abe5778", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9e7b15c-61f7-4b86-90e4-bfc2aad74f55"}}}]}, {"uuid": "3ac66ec1-6fb6-4c36-a2c3-e32d08f7d9ac", "name": "load_p1rlv785_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa98d6c6-7086-4033-a9af-c0a33e802942"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "45345969-43ff-4427-b01b-d383cffda331"}}}}, {"uuid": "fb9f3072-5ef5-48d6-9d07-2d2658810068", "name": "bd9c4191-59de-45a1-814b-d90568788fe8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.948680292874151, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.769988963438003, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "593c1512-b383-4ac8-98a4-827a2fcb93a6", "name": "177fe3d7-2b35-484b-875f-e7d560930137", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fb9f3072-5ef5-48d6-9d07-2d2658810068"}}}]}, {"uuid": "e1ddc0aa-3e8d-4766-a484-644f692e29e1", "name": "load_p1rlv785_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa98d6c6-7086-4033-a9af-c0a33e802942"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "593c1512-b383-4ac8-98a4-827a2fcb93a6"}}}}, {"uuid": "bc760cd2-a200-4bfd-9186-1f7acd7a1a81", "name": "456087ae-8687-410b-a07b-5303e9da9193_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0491915565570302, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1506537762556939, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5b15a43f-f62b-4614-9c68-35ba1f43fb5c", "name": "186ec91e-c15b-4f56-98ff-82750ff6d8db", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bc760cd2-a200-4bfd-9186-1f7acd7a1a81"}}}]}, {"uuid": "d859e8e9-e36f-418b-a618-7d5a905ca868", "name": "load_p1rlv786_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180adab2-e49b-42e9-9aeb-42be0a7686c5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5b15a43f-f62b-4614-9c68-35ba1f43fb5c"}}}}, {"uuid": "3a1c632a-ce42-42cb-ae94-48b8907ff209", "name": "bb5dcfcf-f220-438e-a891-8f1e45366dbb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0491915565570302, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1506537762556939, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aae090e5-66ce-4226-a0dc-088b17d1c483", "name": "c65f9925-017a-4930-8312-dade9bf74b58", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3a1c632a-ce42-42cb-ae94-48b8907ff209"}}}]}, {"uuid": "8dd7c44e-a653-498e-be77-b6b12110969f", "name": "load_p1rlv786_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180adab2-e49b-42e9-9aeb-42be0a7686c5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aae090e5-66ce-4226-a0dc-088b17d1c483"}}}}, {"uuid": "473251b2-1ab4-4ce0-bfea-f97b3f8f6ebb", "name": "79beb2c9-bac5-4287-a9ef-9ce61c94224a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.246762625041277, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42085270345980447, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0891e070-d97c-48e0-ba7d-2b680fa93ce3", "name": "adaf6100-1d2d-4134-a35b-50bc5f41a61d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "473251b2-1ab4-4ce0-bfea-f97b3f8f6ebb"}}}]}, {"uuid": "85d88516-8681-4092-8522-e96e03808247", "name": "load_p1rlv787_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0089ee3-0cb4-434c-adc4-c91a8441ef0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0891e070-d97c-48e0-ba7d-2b680fa93ce3"}}}}, {"uuid": "65eaa6dd-e9ea-4531-b49b-9e6c44dfb463", "name": "fc3a09c9-d1fc-47ad-ba9f-e05638d984b6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.246762625041277, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42085270345980447, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5183e717-19d2-4093-a229-bfdecdd6a6b7", "name": "57ceeb5c-7caa-4188-ac3e-484dd9a20a93", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "65eaa6dd-e9ea-4531-b49b-9e6c44dfb463"}}}]}, {"uuid": "fa119cc4-4020-42a3-bed6-cb4c53fe15f7", "name": "load_p1rlv787_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0089ee3-0cb4-434c-adc4-c91a8441ef0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5183e717-19d2-4093-a229-bfdecdd6a6b7"}}}}, {"uuid": "7eb3f9c1-caf9-45b3-854a-b2e7498e6012", "name": "caa89576-3694-45c2-b0d2-dfa67d478a27_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8660061383019082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.44544683702444765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "30ce92a9-817f-477c-a08d-b1c98ef75f61", "name": "1f49a407-37ad-484a-8b93-f026dedbc504", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7eb3f9c1-caf9-45b3-854a-b2e7498e6012"}}}]}, {"uuid": "a6ef7793-92d0-4190-9487-746bd46b1fe3", "name": "load_p1rlv788_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9f470d9-6ead-4413-ad8a-7ccc69ae9237"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "30ce92a9-817f-477c-a08d-b1c98ef75f61"}}}}, {"uuid": "1fe997d5-481e-4bb5-886a-36f042ab7a4a", "name": "76064b24-cdad-4a93-b0aa-69817f67638c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8660061383019082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.44544683702444765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4b9db413-91c2-4b76-9e16-748421872017", "name": "f135eded-859b-48d6-a770-7d6ce70bceb3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1fe997d5-481e-4bb5-886a-36f042ab7a4a"}}}]}, {"uuid": "a1293b75-945a-4a8b-9e75-47fe77b2ac08", "name": "load_p1rlv788_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9f470d9-6ead-4413-ad8a-7ccc69ae9237"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4b9db413-91c2-4b76-9e16-748421872017"}}}}, {"uuid": "2995fa38-c796-407f-b921-aa40a63a21a5", "name": "da1c4ecf-5cec-4267-81c4-b45fc78f34d1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1146755706450526, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5956233891083068, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3f242781-55ca-45dc-80f0-7e15ad23a6ca", "name": "63e7d2cd-0504-4847-8012-5e2723d55f6a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2995fa38-c796-407f-b921-aa40a63a21a5"}}}]}, {"uuid": "07f0059d-15e9-4a01-9e08-bee0656f3c1b", "name": "load_p1rlv789_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9ce2439-fcc7-4965-81ee-f875db83b003"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3f242781-55ca-45dc-80f0-7e15ad23a6ca"}}}}, {"uuid": "cd40daea-6940-49fa-b2d8-685091be24c7", "name": "7cc7695b-9b9e-42fc-b8fd-de7fda9a3f7f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1146755706450526, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5956233891083068, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "abd3d946-ff0d-4c90-b67c-3a474857170f", "name": "cfc12075-8e2f-4e2d-9c71-5c99072bdd41", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cd40daea-6940-49fa-b2d8-685091be24c7"}}}]}, {"uuid": "8e04a276-1831-4a10-89ac-8e0cc810ac43", "name": "load_p1rlv789_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9ce2439-fcc7-4965-81ee-f875db83b003"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "abd3d946-ff0d-4c90-b67c-3a474857170f"}}}}, {"uuid": "67358195-51ef-441c-a590-de52ce404ae5", "name": "313602cc-e67f-4578-abdd-9f8eb3be2c03_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.507865878359724, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5977385470921427, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a32bf0e6-797a-4730-a940-ac2793a72dda", "name": "390e6fa0-70fa-4622-953b-612514c57b46", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "67358195-51ef-441c-a590-de52ce404ae5"}}}]}, {"uuid": "32d4ada8-ea2a-4266-9e2e-0aee1c3746c3", "name": "load_p1rlv790_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf42fa7f-370e-400e-8f6d-76eb8c70ecb9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a32bf0e6-797a-4730-a940-ac2793a72dda"}}}}, {"uuid": "059c12b8-7a4d-474e-b868-f82f1115f672", "name": "d3aa0c32-6da1-4087-b743-172cc3bf2a07_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.507865878359724, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5977385470921427, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bc4817fe-0da3-43f5-ad60-a477d7c8576b", "name": "2a94ff1c-f549-461e-8968-54329535288e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "059c12b8-7a4d-474e-b868-f82f1115f672"}}}]}, {"uuid": "cd07f9ea-7435-4b93-8fcc-a44d99da4aae", "name": "load_p1rlv790_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf42fa7f-370e-400e-8f6d-76eb8c70ecb9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bc4817fe-0da3-43f5-ad60-a477d7c8576b"}}}}, {"uuid": "f2079efb-f07c-41bc-94c2-584ae629605d", "name": "86210398-a9a8-4879-9e3c-b7e182dc94e5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.8801930784369265, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0115137645096066, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "58867ff1-aac8-41f5-a8f6-037f853e3cd6", "name": "72ae5231-2aed-4bdb-b71a-f9c042ea9b3f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f2079efb-f07c-41bc-94c2-584ae629605d"}}}]}, {"uuid": "6d6e5bd0-4069-4b2b-8a3b-a4b8156b0b6b", "name": "load_p1rlv791_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fe9bb3f-e3c1-4b59-b39f-f62271a55bdd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "58867ff1-aac8-41f5-a8f6-037f853e3cd6"}}}}, {"uuid": "cc6c614d-1f66-4f40-a958-de8b63523d00", "name": "1d8a2af4-40d4-47c0-a99f-71754c62732e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.8801930784369265, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0115137645096066, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d576a3e9-8707-405e-ad02-8b47148a6b96", "name": "458448a9-d21f-4598-ba66-2148ed15878b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cc6c614d-1f66-4f40-a958-de8b63523d00"}}}]}, {"uuid": "1fb64f7e-30c1-4b55-b646-32d6d63c9137", "name": "load_p1rlv791_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fe9bb3f-e3c1-4b59-b39f-f62271a55bdd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d576a3e9-8707-405e-ad02-8b47148a6b96"}}}}, {"uuid": "c8ca456b-103e-40a8-826f-9658b81c0c8c", "name": "a58593df-f306-44d4-956d-19bd50b79f7a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7628538083737542, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7287957147649712, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d505cfe9-c55f-44e1-a8d2-8b1fffbb1241", "name": "106e892e-878c-4a5c-ad20-d2887fbfb751", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c8ca456b-103e-40a8-826f-9658b81c0c8c"}}}]}, {"uuid": "31f2fd4f-1cac-4765-a201-816b91860a72", "name": "load_p1rlv792_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f806232e-0a52-46d5-80f7-7ea3a914137a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d505cfe9-c55f-44e1-a8d2-8b1fffbb1241"}}}}, {"uuid": "92485c07-f490-4bbc-a625-20051376dba7", "name": "e18075de-75e7-40cb-a8c4-29a5ff6f87ed_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7628538083737542, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7287957147649712, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "967be153-6d35-4c97-a427-d053a9ef357e", "name": "a2138130-423b-4e33-8b77-76ebb1b6dafa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "92485c07-f490-4bbc-a625-20051376dba7"}}}]}, {"uuid": "b24d80d1-0fb7-41c9-98d8-b2e48b6d99c1", "name": "load_p1rlv792_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f806232e-0a52-46d5-80f7-7ea3a914137a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "967be153-6d35-4c97-a427-d053a9ef357e"}}}}, {"uuid": "4f125316-f1dc-4264-a48a-3eb422837b73", "name": "ca0b469e-5b49-4e05-a6e6-f1796455c4fe_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3510125413548424, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5621017434083633, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7f3c53b7-1c9e-4f38-aa93-41bfe2410c5f", "name": "096b7ce4-2993-4f74-a691-64c767bd5807", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4f125316-f1dc-4264-a48a-3eb422837b73"}}}]}, {"uuid": "6624cffa-97dd-4f2f-a93c-6283af6764c1", "name": "load_p1rlv793_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e8c4bc9-0688-43e6-93a8-9664c9b618b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7f3c53b7-1c9e-4f38-aa93-41bfe2410c5f"}}}}, {"uuid": "48ff241c-9d0d-4e99-9630-c7c010dcbfc4", "name": "458cf665-3d81-4248-8d50-75e991f6dd7a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3510125413548424, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5621017434083633, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "25886f1d-2b99-4844-9818-12e1072e4078", "name": "fdb32a95-93af-4633-951a-7ce676661d31", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "48ff241c-9d0d-4e99-9630-c7c010dcbfc4"}}}]}, {"uuid": "ba48e384-469b-4bfe-b930-408e95243541", "name": "load_p1rlv793_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e8c4bc9-0688-43e6-93a8-9664c9b618b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "25886f1d-2b99-4844-9818-12e1072e4078"}}}}, {"uuid": "a433be39-5d29-46d5-af99-b5433f4eb28e", "name": "4cbdee84-762e-4ffe-b5ca-739d59c579f6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8660061383019082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.44544683702444765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "563fee7b-f9a7-4c21-ad96-84ff8c32ca24", "name": "794f19a1-12cb-4fd3-8a38-28db448457eb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a433be39-5d29-46d5-af99-b5433f4eb28e"}}}]}, {"uuid": "d4736669-6c0f-458e-b2bf-564059c09a88", "name": "load_p1rlv794_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eecc456-41af-4242-ab30-d8ca45d55a2c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "563fee7b-f9a7-4c21-ad96-84ff8c32ca24"}}}}, {"uuid": "ed90e9c2-75fc-4ccb-a6ea-9678e556a42b", "name": "fa8d3016-4cf5-4d13-b2fa-6e4f6cd801c1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8660061383019082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.44544683702444765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "46083046-bc68-4957-9762-f7c32f3ed87a", "name": "73f557bd-a82b-4859-a8a7-96565bb7ca35", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ed90e9c2-75fc-4ccb-a6ea-9678e556a42b"}}}]}, {"uuid": "77460682-1d6c-4df8-8eae-c8393e31aca8", "name": "load_p1rlv794_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eecc456-41af-4242-ab30-d8ca45d55a2c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "46083046-bc68-4957-9762-f7c32f3ed87a"}}}}, {"uuid": "6c710181-e2b6-4826-b884-cb0d10b219a0", "name": "253e183e-ba89-4e13-b8ad-ff127796e36c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.083951745833768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9853982282300497, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0653bc01-11d5-4990-9a66-94333ae0f39e", "name": "94bdb433-37d8-4f57-8525-84aec78cf6a4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c710181-e2b6-4826-b884-cb0d10b219a0"}}}]}, {"uuid": "1842e1ea-1f3a-44f6-86da-050c29265f33", "name": "load_p1rlv795_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb137176-0642-4d87-ae40-1b7b0e1cb214"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0653bc01-11d5-4990-9a66-94333ae0f39e"}}}}, {"uuid": "c9e78314-1f2b-48b3-86db-2504aa47b9d1", "name": "517dfb60-554d-4efb-95e7-209b287750bd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.083951745833768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9853982282300497, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e17db933-2332-4184-acb3-983d9976b88d", "name": "00024c62-6f74-4838-ac6f-c4e4ab032493", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9e78314-1f2b-48b3-86db-2504aa47b9d1"}}}]}, {"uuid": "11d0c30a-c620-42e1-9c1b-108bbaf9c2c8", "name": "load_p1rlv795_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb137176-0642-4d87-ae40-1b7b0e1cb214"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e17db933-2332-4184-acb3-983d9976b88d"}}}}, {"uuid": "dd4817ff-9567-48fc-a612-d4f252b795a5", "name": "34accbdf-746d-4883-9760-04afcf68e08e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0085854932437286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7150296414254909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "755376c1-8d90-4413-bb42-962c9347ffbf", "name": "29e47ff3-8353-40ff-8f54-01b484e9267c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dd4817ff-9567-48fc-a612-d4f252b795a5"}}}]}, {"uuid": "32b85a02-d101-4205-852e-f12e6d5349e0", "name": "load_p1rlv796_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59662cef-c126-4188-ad86-844f6cabaf34"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "755376c1-8d90-4413-bb42-962c9347ffbf"}}}}, {"uuid": "d09ed02f-0edd-4bc2-83fd-f36c855f6ec6", "name": "764f4a73-d05f-4d60-9bd3-bf7d1e36c0e1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0085854932437286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7150296414254909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "79449805-4e72-494a-87d2-57dad2817656", "name": "7bba4b8f-3ec6-4e8c-bf7d-471827c3cd54", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d09ed02f-0edd-4bc2-83fd-f36c855f6ec6"}}}]}, {"uuid": "44f27ce1-c9f1-4f28-a727-53e65be90070", "name": "load_p1rlv796_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59662cef-c126-4188-ad86-844f6cabaf34"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "79449805-4e72-494a-87d2-57dad2817656"}}}}, {"uuid": "b5f8d76c-a753-4d81-b731-5d3dff6e99d9", "name": "5a907586-3b6b-44f9-b487-1a3d596627ed_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.127438645009231, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8176304041402817, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c6a0a7a4-5fe0-4b41-8a8f-0a33c6123d0b", "name": "0926481c-375c-45c6-8bc9-796e6fccc09b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5f8d76c-a753-4d81-b731-5d3dff6e99d9"}}}]}, {"uuid": "a12f00cb-3c93-410c-a003-2b94e48aeec0", "name": "load_p1rlv797_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b1c34f1-2613-46aa-9a9f-686ee518e559"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c6a0a7a4-5fe0-4b41-8a8f-0a33c6123d0b"}}}}, {"uuid": "1518672b-3dd9-496d-8565-f93c0eed2369", "name": "7a4a591f-f997-471d-ab7e-16e7d400ace9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.127438645009231, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8176304041402817, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a47ee959-4933-4ad4-ae2c-7fe6b20ce82a", "name": "ac50e232-492f-46d1-8e34-e3bfc191470b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1518672b-3dd9-496d-8565-f93c0eed2369"}}}]}, {"uuid": "cf856919-7fc5-4818-8d6f-28087f021ebe", "name": "load_p1rlv797_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b1c34f1-2613-46aa-9a9f-686ee518e559"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a47ee959-4933-4ad4-ae2c-7fe6b20ce82a"}}}}, {"uuid": "d4417dbc-b4db-49bd-8feb-627965850552", "name": "7bd8265e-cdf2-4bc7-ad3d-09ac6aeb4d16_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.839033632547656, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.36892018645953045, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b7b0c9cb-b446-4f62-9873-638405bd7a3d", "name": "437537d8-a0dd-416a-a449-1a6a634f5d26", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d4417dbc-b4db-49bd-8feb-627965850552"}}}]}, {"uuid": "1a71adb8-ddc6-4746-9b53-90cfd4bf60ac", "name": "load_p1rlv798_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c30005d7-7e42-4a08-8935-0c7227fba4a6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b7b0c9cb-b446-4f62-9873-638405bd7a3d"}}}}, {"uuid": "86ef5b5f-77f6-450d-b85a-2d57d870054c", "name": "9345b937-0745-4a39-8b8e-cca85f4d14b4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.839033632547656, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.36892018645953045, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6df4ee25-a6ea-4b19-9eeb-8e5124bd1fdf", "name": "335aa7fd-9a7a-43c0-94a5-69d03ad5089a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "86ef5b5f-77f6-450d-b85a-2d57d870054c"}}}]}, {"uuid": "475ac95f-30e7-4ab2-b9f6-97693f55195d", "name": "load_p1rlv798_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c30005d7-7e42-4a08-8935-0c7227fba4a6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6df4ee25-a6ea-4b19-9eeb-8e5124bd1fdf"}}}}, {"uuid": "27620e64-36f4-40ba-978e-de18bc4e532b", "name": "62e4942b-d3a0-498c-948a-12e3b7f8dcad_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.046232297850773, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7285366000251032, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cac38115-fa29-4a33-b1ef-955dc8b3b3f4", "name": "4ddf73be-47d5-41d8-a0af-f1089e7f3fa8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "27620e64-36f4-40ba-978e-de18bc4e532b"}}}]}, {"uuid": "ed1b18d9-960b-4b41-9994-578e21b4add9", "name": "load_p1rlv799_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f706d9d-0cb1-453b-9ca5-377f7d766099"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cac38115-fa29-4a33-b1ef-955dc8b3b3f4"}}}}, {"uuid": "58b99372-8eba-4bfd-9257-73cafdb761d2", "name": "fe6be4cf-f2be-4f13-9b0d-2925c42f365e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.046232297850773, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7285366000251032, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "09e0bc18-e092-4871-9310-559dd3979e4f", "name": "afbdf141-92fc-44c6-8829-317e342e3cd2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58b99372-8eba-4bfd-9257-73cafdb761d2"}}}]}, {"uuid": "191e9bea-c480-48d9-95bb-178ae994ab05", "name": "load_p1rlv799_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f706d9d-0cb1-453b-9ca5-377f7d766099"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "09e0bc18-e092-4871-9310-559dd3979e4f"}}}}, {"uuid": "cdc15692-4ad5-4014-a5ed-35a494709340", "name": "9a65e01b-2a25-4c33-9767-a0c5f3a169d9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2795803428770153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1698974287191981, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "30c757e1-f5f5-478f-8cfe-1b6a8ad5bf87", "name": "238dc65a-8496-493e-ba24-9caa91cdd716", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cdc15692-4ad5-4014-a5ed-35a494709340"}}}]}, {"uuid": "e20c0dc1-5195-4f50-8e05-0dd4080c5b83", "name": "load_p1rlv800_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3126c61-9602-45cf-8d57-27d26c14ca7e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "30c757e1-f5f5-478f-8cfe-1b6a8ad5bf87"}}}}, {"uuid": "f8b39291-b936-4c7e-a0c8-c43db1817944", "name": "7f80a2f3-4e2c-4048-bf17-54d0f67df2f1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2795803428770153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1698974287191981, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d540a418-a6ec-4518-bc0e-61fc04cc42b2", "name": "ae58a800-02f8-4f30-a632-f7d4f32f9846", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8b39291-b936-4c7e-a0c8-c43db1817944"}}}]}, {"uuid": "4cbeba7c-b5dd-4e8f-bbee-7081b2b5b5f8", "name": "load_p1rlv800_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3126c61-9602-45cf-8d57-27d26c14ca7e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d540a418-a6ec-4518-bc0e-61fc04cc42b2"}}}}, {"uuid": "e25eb9c7-da87-4f68-9322-79e1381c82c9", "name": "4a7ac419-9d21-4faa-bf7a-df40e3c17cc5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2142575595505583, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8511261488468437, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c1b13cd-f503-4295-800a-46586da7cbaa", "name": "d29ba3ab-cbae-4437-9a3a-154ba2c85de5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e25eb9c7-da87-4f68-9322-79e1381c82c9"}}}]}, {"uuid": "d1a79f47-823e-489e-9102-bfd8661a0698", "name": "load_p1rlv801_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ecc45b2-1fbe-4a31-995f-e2f8fffe61a7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c1b13cd-f503-4295-800a-46586da7cbaa"}}}}, {"uuid": "7c34c779-171c-4a0e-9e87-e7988cb61122", "name": "0ab8dd7e-65d8-4fd1-a56e-86ebbc67d9a5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2142575595505583, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8511261488468437, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "620ff808-897f-4bb3-8cf6-1a3e02e6a00d", "name": "7b4b2a27-3f17-4c47-bda6-8f9c0aaf4e06", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7c34c779-171c-4a0e-9e87-e7988cb61122"}}}]}, {"uuid": "04816d23-d595-4b23-9d7c-736dd614d965", "name": "load_p1rlv801_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ecc45b2-1fbe-4a31-995f-e2f8fffe61a7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "620ff808-897f-4bb3-8cf6-1a3e02e6a00d"}}}}, {"uuid": "6a83fbb7-afe1-47d8-b2da-92214e07d67a", "name": "b078b8bf-7601-453e-a44d-d6208a434655_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.621947646480353, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0332384495271123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9b9deaaf-bc34-40fb-82b1-6502cd1d6393", "name": "c5ab4f42-4ac5-43ff-9588-89aa16263451", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6a83fbb7-afe1-47d8-b2da-92214e07d67a"}}}]}, {"uuid": "226177fd-fc5f-43d1-92ad-aa76bcd7f486", "name": "load_p1rlv802_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2436086-d5c4-4b70-a402-e7d1b6f5b77e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9b9deaaf-bc34-40fb-82b1-6502cd1d6393"}}}}, {"uuid": "edadc232-577f-4196-9c92-4982f9b32db8", "name": "a8b3a10b-50ff-4be6-b58b-612ba1efca1d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.621947646480353, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0332384495271123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f8c9d64d-a92c-4fab-a690-34c10f1e6876", "name": "de4abd99-b477-48f0-854d-a5de0fbab94f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "edadc232-577f-4196-9c92-4982f9b32db8"}}}]}, {"uuid": "5513bc2f-7647-49ad-acf0-cad7dc4344b8", "name": "load_p1rlv802_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2436086-d5c4-4b70-a402-e7d1b6f5b77e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f8c9d64d-a92c-4fab-a690-34c10f1e6876"}}}}, {"uuid": "4a6e72dc-0fd5-4a6d-a760-6bca463c7958", "name": "2d097c22-693f-465b-ab51-97c98658be1b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.991433457795887, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5982568468826307, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "93e40e12-3a0b-4142-b1b8-2798f6023a59", "name": "6324b962-f7ac-4458-92f4-14eff840fa9d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4a6e72dc-0fd5-4a6d-a760-6bca463c7958"}}}]}, {"uuid": "1a518b9a-23c3-404f-8aa6-9fef87d86748", "name": "load_p1rlv803_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "018c978c-5673-4090-9792-b75ee161f6d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "93e40e12-3a0b-4142-b1b8-2798f6023a59"}}}}, {"uuid": "f1d9e12c-3c70-4e12-b43a-42993ad845bf", "name": "4584a0d0-a1a7-4113-89fd-c3670eef0f71_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.991433457795887, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5982568468826307, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "13304da8-6eed-4a95-be24-9c06f1773a88", "name": "40305169-1355-4f4b-b05e-9a9f83d02553", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f1d9e12c-3c70-4e12-b43a-42993ad845bf"}}}]}, {"uuid": "4119dd23-3bfa-4b70-a7b2-b5cfe56c9ba1", "name": "load_p1rlv803_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "018c978c-5673-4090-9792-b75ee161f6d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "13304da8-6eed-4a95-be24-9c06f1773a88"}}}}, {"uuid": "c1fb01ee-0a2a-408e-b93d-63b1e0ae075c", "name": "0453fe34-a68d-4aa6-b3f3-f8be97681717_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.292799122473319, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5385753507809203, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f3134e33-7b18-431b-b107-337c262ecfb1", "name": "c1f9910b-dff3-4cd6-a77d-a29738ad9094", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c1fb01ee-0a2a-408e-b93d-63b1e0ae075c"}}}]}, {"uuid": "22899ffe-ad39-4be8-963a-658a3c025e92", "name": "load_p1rlv804_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a11ba246-99d9-4cf5-a557-bec53c75e6fb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f3134e33-7b18-431b-b107-337c262ecfb1"}}}}, {"uuid": "0577474f-713e-42a1-8360-6b5315691b7b", "name": "841c637a-f73e-4be3-851d-44ee71e33f7e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.292799122473319, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5385753507809203, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a70eccf7-9561-45ff-8e98-edcb8caddc1c", "name": "0bfa7b8d-3957-40b6-a517-47cc3bccd8c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0577474f-713e-42a1-8360-6b5315691b7b"}}}]}, {"uuid": "0d0dfa2c-b47a-4f09-894d-383a0abaa69f", "name": "load_p1rlv804_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a11ba246-99d9-4cf5-a557-bec53c75e6fb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a70eccf7-9561-45ff-8e98-edcb8caddc1c"}}}}, {"uuid": "cb90b3f2-2054-4a12-9bc1-174278764562", "name": "482d07e2-73a2-47d8-8077-9f733d11d325_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.987999469244499, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42543082019456707, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "02b2e4ae-c602-4a01-8dd0-8d4927f5c6bc", "name": "5f096ec6-979d-4f96-b37f-e4c023012d2c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cb90b3f2-2054-4a12-9bc1-174278764562"}}}]}, {"uuid": "94306602-9d91-4717-ac32-7601a7eec3a6", "name": "load_p1rlv805_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0475b34e-14ab-48e4-9df7-7444de1cde7d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "02b2e4ae-c602-4a01-8dd0-8d4927f5c6bc"}}}}, {"uuid": "e6faa0df-44b4-4ab4-918b-1ac3460b4f1a", "name": "354eb4e2-ce6d-4c16-bebc-38a7c83ac69b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.987999469244499, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42543082019456707, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9d416776-a183-456b-b3f3-1e4c13d23875", "name": "0e5a2587-eec9-45b4-b4aa-e20da2ae3c80", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e6faa0df-44b4-4ab4-918b-1ac3460b4f1a"}}}]}, {"uuid": "7f0817b8-99e8-4e61-bae4-015564a8978b", "name": "load_p1rlv805_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0475b34e-14ab-48e4-9df7-7444de1cde7d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9d416776-a183-456b-b3f3-1e4c13d23875"}}}}, {"uuid": "a1ae1f2a-6525-4488-8ddb-939e2c0a6bd9", "name": "86da67d3-dce4-40fa-924a-bfd2f591e54f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4950137537296666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31506625700854357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1176d2d0-4537-427d-99f7-59a44be17d94", "name": "db2b683a-b000-4b9c-9f6c-6fa3b027495e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a1ae1f2a-6525-4488-8ddb-939e2c0a6bd9"}}}]}, {"uuid": "09209c20-e17c-4675-b697-6afbacbb6e84", "name": "load_p1rlv806_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d9f269a-e476-4b82-a258-479d812d008d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1176d2d0-4537-427d-99f7-59a44be17d94"}}}}, {"uuid": "449e2e01-3cda-4040-bc51-39368c4a4046", "name": "a35047b0-fa29-4029-8d3a-5db7b73ea064_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4950137537296666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31506625700854357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7b3eeaba-f61b-4142-ae6e-89b24fce4547", "name": "a1528b96-8255-40de-8286-0171a4fe4581", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "449e2e01-3cda-4040-bc51-39368c4a4046"}}}]}, {"uuid": "dcc8b148-384f-4fa3-812b-52a49190219f", "name": "load_p1rlv806_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d9f269a-e476-4b82-a258-479d812d008d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7b3eeaba-f61b-4142-ae6e-89b24fce4547"}}}}, {"uuid": "71b51c74-d6e6-4e69-ac4a-677a95d0675a", "name": "21e2b630-e823-42b6-bf6d-863135e0c886_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.107858967059457, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3651352875232526, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ed616a72-ab12-4ce3-bace-d557ffc4cf34", "name": "e5242d07-16b8-465d-a1e4-90a257ee9cd7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "71b51c74-d6e6-4e69-ac4a-677a95d0675a"}}}]}, {"uuid": "fa476b20-630e-4d59-9f0f-a8d14a86554f", "name": "load_p1rlv807_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa259be8-8a61-461a-9e58-d4aaf1ce82db"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ed616a72-ab12-4ce3-bace-d557ffc4cf34"}}}}, {"uuid": "72f20477-33d2-4d5f-98ed-d5010b124c54", "name": "6ffe1ec2-6fcf-4f97-87fc-26865a0b7b7e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.107858967059457, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3651352875232526, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8b348d9f-802d-4db1-af83-c40d16a11169", "name": "54895934-cecc-4d92-8979-d00e62ba2e97", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72f20477-33d2-4d5f-98ed-d5010b124c54"}}}]}, {"uuid": "1d5c684d-9e7e-4e27-9f6c-89984f50cbb4", "name": "load_p1rlv807_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa259be8-8a61-461a-9e58-d4aaf1ce82db"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8b348d9f-802d-4db1-af83-c40d16a11169"}}}}, {"uuid": "10863d87-e2c5-4f8a-95c4-f779a208f6d2", "name": "cd9fef9d-a919-4b00-921e-8c2298a2343b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.847886228314274, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0445060168814917, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9d60dc14-18d9-41dc-bac8-1dc54d1cdd83", "name": "c37b3af4-0023-4302-82e0-be5197005d2b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "10863d87-e2c5-4f8a-95c4-f779a208f6d2"}}}]}, {"uuid": "c3bf69ee-2387-463a-a620-8889c6e696ed", "name": "load_p1rlv808_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dcb86a4-e6d7-48b4-b5c2-904635de271b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9d60dc14-18d9-41dc-bac8-1dc54d1cdd83"}}}}, {"uuid": "0ff26188-9f62-4401-8eaf-cfb058a40d76", "name": "f8daf638-4988-4e32-a558-2f17ccc10c4c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.847886228314274, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0445060168814917, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1108b691-7c26-477f-9c44-852d57e6c28a", "name": "36964797-4a01-4e6b-8193-17fdf9418144", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0ff26188-9f62-4401-8eaf-cfb058a40d76"}}}]}, {"uuid": "275d8b4b-180a-4ba5-8afe-6c5a984f910e", "name": "load_p1rlv808_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dcb86a4-e6d7-48b4-b5c2-904635de271b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1108b691-7c26-477f-9c44-852d57e6c28a"}}}}, {"uuid": "b90c43fd-9545-43d5-aa26-284f131d6951", "name": "fadbe899-067e-4fda-bd48-0fcb3363d23c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.739385174805638, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.976019322648958, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "861fff20-0acd-41c1-a98a-ffd197592db2", "name": "5c1659e7-028e-4567-bd50-da2566583a1d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b90c43fd-9545-43d5-aa26-284f131d6951"}}}]}, {"uuid": "9b75a966-d766-4da4-b3a9-99bb64317eaa", "name": "load_p1rlv809_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e0f8ee8-795f-4bea-bf7a-e2c477eefb89"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "861fff20-0acd-41c1-a98a-ffd197592db2"}}}}, {"uuid": "67a83380-fd27-4dbf-9f41-5025a8c30e9d", "name": "c4165a6b-63a1-4dbf-b432-ba5eb71b30bd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.739385174805638, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.976019322648958, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a2dcb90f-3ae2-411f-9321-5e5cf47b9fe9", "name": "1d108e2d-210d-4c1b-8fea-98eaaaac21cd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "67a83380-fd27-4dbf-9f41-5025a8c30e9d"}}}]}, {"uuid": "3f913e9e-d1c1-4fff-b236-303d44b401dc", "name": "load_p1rlv809_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e0f8ee8-795f-4bea-bf7a-e2c477eefb89"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a2dcb90f-3ae2-411f-9321-5e5cf47b9fe9"}}}}, {"uuid": "411f0651-0785-4e4f-99cc-b3715b12ea36", "name": "c1c6ca54-dd95-46f0-b798-4c803fd7167e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8309189378455104, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6069744647018672, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "03f741ce-96ad-4a1b-8277-ce411a51c68b", "name": "c368e4cc-7046-4395-bb00-5dce2f763b1b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "411f0651-0785-4e4f-99cc-b3715b12ea36"}}}]}, {"uuid": "28a09673-3ba1-4c43-9c43-3b7aa624b2a8", "name": "load_p1rlv810_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb4a881f-684d-48e4-a6f0-5832f73d140a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "03f741ce-96ad-4a1b-8277-ce411a51c68b"}}}}, {"uuid": "7901af69-6f57-4a73-b623-9e63c9300013", "name": "d8d7a554-5a06-4356-8cd0-15d4eb3e4a88_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8309189378455104, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6069744647018672, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f103a8ea-9301-4fda-81c7-a2f0b00444ea", "name": "0c4a7bcb-a22e-4fa1-abc1-71508477e6a6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7901af69-6f57-4a73-b623-9e63c9300013"}}}]}, {"uuid": "9704a4db-8a6e-4150-a7a1-4434d753063b", "name": "load_p1rlv810_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb4a881f-684d-48e4-a6f0-5832f73d140a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f103a8ea-9301-4fda-81c7-a2f0b00444ea"}}}}, {"uuid": "58540381-46f0-4842-b1f7-6f12c33c1aaa", "name": "3a3f1738-9558-40b1-803f-36ade87a88d0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7362273540893955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24527287728713068, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "535428b8-7298-4e27-8f95-a29be5db7f75", "name": "69a403d1-f846-495a-8ee7-1090e160611e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58540381-46f0-4842-b1f7-6f12c33c1aaa"}}}]}, {"uuid": "6aa9335f-11aa-4850-b488-a3b57ff0810c", "name": "load_p1rlv811_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "052949b1-9e85-4be7-993c-9e97efda3657"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "535428b8-7298-4e27-8f95-a29be5db7f75"}}}}, {"uuid": "d8097276-eed1-4787-91df-157c2fe5246c", "name": "74da4ae4-969e-4389-ba97-5e937297c4b4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7362273540893955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24527287728713068, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ff4d4f14-c6e8-4311-97fb-9a84145923c4", "name": "590a0c92-c812-41de-ae77-37676b1dd971", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d8097276-eed1-4787-91df-157c2fe5246c"}}}]}, {"uuid": "5e75c977-5c96-49b7-b33e-bd0dddd5db3b", "name": "load_p1rlv811_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "052949b1-9e85-4be7-993c-9e97efda3657"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ff4d4f14-c6e8-4311-97fb-9a84145923c4"}}}}, {"uuid": "d9c9c1f7-9a73-43ad-89bd-318929ad3ab7", "name": "1069ede5-9826-4402-8e4a-ceb7acb95f5b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0599252267318962, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3748861224482183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50152347-5bdb-49be-b9e0-01759af6ed74", "name": "b2bf3543-58fa-4099-9477-15cd1ff1a0b7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d9c9c1f7-9a73-43ad-89bd-318929ad3ab7"}}}]}, {"uuid": "82dea5fe-cd3a-42bd-a5f2-9d088a939774", "name": "load_p1rlv812_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26fea867-af5f-4213-b9c3-487975d1285e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50152347-5bdb-49be-b9e0-01759af6ed74"}}}}, {"uuid": "4c83845b-74b7-4ab5-8191-373fe40720fd", "name": "6faaffee-3331-4355-aa1e-1c718446170d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0599252267318962, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3748861224482183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "667a104b-536d-42cb-816c-35a837cf2f9c", "name": "f4293f81-a29c-4b0d-9b5e-0819f2ea6af3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4c83845b-74b7-4ab5-8191-373fe40720fd"}}}]}, {"uuid": "d01e44be-07f1-4f33-9f4d-b8b64c9f8c4e", "name": "load_p1rlv812_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26fea867-af5f-4213-b9c3-487975d1285e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "667a104b-536d-42cb-816c-35a837cf2f9c"}}}}, {"uuid": "74c8e1af-8f80-4b63-8126-b89b014016fe", "name": "80123125-5b25-452c-aa68-8772e6db11d1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7457942211533133, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8784341351558463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bc2a2099-56de-42de-8494-e78cc7abf913", "name": "3f111631-2636-4a5d-95d6-45a74a6c73c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "74c8e1af-8f80-4b63-8126-b89b014016fe"}}}]}, {"uuid": "c527ba67-9ea4-4e8e-b824-7e21912984ae", "name": "load_p1rlv813_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10d44b60-55c0-4d78-abbb-52c8cd67134b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bc2a2099-56de-42de-8494-e78cc7abf913"}}}}, {"uuid": "76e54313-3a38-4657-9e11-ca3a54a65c86", "name": "6e582f0d-b6ca-41f6-9d92-3c66c8efced8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7457942211533133, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8784341351558463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7bd4b1d3-e002-4251-8d5f-b1ab9b73ea9f", "name": "2547f8ca-a395-4e67-854e-078bfad68612", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "76e54313-3a38-4657-9e11-ca3a54a65c86"}}}]}, {"uuid": "020e8cbe-3954-4821-8e3a-e5aeec53bd36", "name": "load_p1rlv813_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10d44b60-55c0-4d78-abbb-52c8cd67134b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7bd4b1d3-e002-4251-8d5f-b1ab9b73ea9f"}}}}, {"uuid": "58ad71a3-0c2d-44a6-b0ee-7505907d451c", "name": "852e816c-ea4f-467b-8a6e-39eccd098c5c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.559104904760759, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9054328372998879, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "67877123-5ca0-4a19-a3b5-dd96d917765e", "name": "4a6c75be-9ab3-4470-b580-fb976de83b81", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58ad71a3-0c2d-44a6-b0ee-7505907d451c"}}}]}, {"uuid": "35d25ebf-a90f-48cc-8646-7ffa7626e103", "name": "load_p1rlv814_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b8065f3-8286-4f99-aa56-b9b631a2f838"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "67877123-5ca0-4a19-a3b5-dd96d917765e"}}}}, {"uuid": "bc3882ff-f092-48c8-bfeb-1052dde4966e", "name": "12d12581-ea08-41f0-971d-8554dadfd08d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.559104904760759, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9054328372998879, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0280bd4b-f7b8-455d-b020-1545d7160332", "name": "a5919842-32a2-4d76-9d02-bdb0b1001d6f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bc3882ff-f092-48c8-bfeb-1052dde4966e"}}}]}, {"uuid": "64cf4715-7576-460b-a418-5f1026488522", "name": "load_p1rlv814_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b8065f3-8286-4f99-aa56-b9b631a2f838"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0280bd4b-f7b8-455d-b020-1545d7160332"}}}}, {"uuid": "16ea51e7-cc44-48d1-ae9b-8225235d9388", "name": "0614d656-6794-4b42-b0fc-736838c79079_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5424601784243566, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31457775613808403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0bba08a5-c480-4c68-91bd-ee13541689d4", "name": "d5448476-a6b8-4f95-9116-644f14416659", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "16ea51e7-cc44-48d1-ae9b-8225235d9388"}}}]}, {"uuid": "f74b3e0a-a07f-41e6-aebd-8ab1b254bb5b", "name": "load_p1rlv815_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a134556-828b-4e0c-8773-2f207802e33a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0bba08a5-c480-4c68-91bd-ee13541689d4"}}}}, {"uuid": "ad0b2281-280e-4076-8064-667a6d21ed4f", "name": "de19320e-a7de-4eb0-99aa-bfe8567f4a97_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5424601784243566, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31457775613808403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f2d71091-b353-43e0-8aa5-403a8f7cb0b4", "name": "4275bf63-4eb4-4851-96cb-99b331938601", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ad0b2281-280e-4076-8064-667a6d21ed4f"}}}]}, {"uuid": "6e68ad30-1e54-48c4-91e8-bf82491286e3", "name": "load_p1rlv815_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a134556-828b-4e0c-8773-2f207802e33a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f2d71091-b353-43e0-8aa5-403a8f7cb0b4"}}}}, {"uuid": "cc6a60b4-daec-4a6e-9d12-9ae8392dd142", "name": "63c541fe-b2e0-4195-add5-1638ee13af84_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.357764823379774, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7869023210214492, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b2886171-89c1-477c-83a0-d51f6cb7b994", "name": "3bf69e6f-2184-4351-891b-529fb58f8505", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cc6a60b4-daec-4a6e-9d12-9ae8392dd142"}}}]}, {"uuid": "1d166bab-8038-4240-bd6a-990676496f71", "name": "load_p1rlv816_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d6de7c2-fd2c-4071-8e90-1513f521cf87"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b2886171-89c1-477c-83a0-d51f6cb7b994"}}}}, {"uuid": "29adaec0-7aae-48a3-ab81-8e9adb2b7dd8", "name": "5b8fe093-71c0-4840-b92f-1c8335949f70_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.357764823379774, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7869023210214492, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "edc520af-667a-4ee9-b69c-602f2ee46cd9", "name": "57027629-6e91-4bed-bfee-cbdba2e2ee83", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "29adaec0-7aae-48a3-ab81-8e9adb2b7dd8"}}}]}, {"uuid": "f806dba9-9864-4a17-98e6-8c7e5e404f25", "name": "load_p1rlv816_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d6de7c2-fd2c-4071-8e90-1513f521cf87"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "edc520af-667a-4ee9-b69c-602f2ee46cd9"}}}}, {"uuid": "40ec427d-4957-4781-9f16-defc4fee8c6c", "name": "275b825d-0d85-47d5-80e1-e7f977a40dcb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1206689642843692, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34257205075767067, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f2e22e49-ad98-46fc-b3f6-b9815b9ab095", "name": "2c11f1b6-aa7c-40a6-b8b2-4e732406033b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "40ec427d-4957-4781-9f16-defc4fee8c6c"}}}]}, {"uuid": "75abaeea-16a0-4cc7-aec6-20c6a7b98961", "name": "load_p1rlv817_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11064c6f-3b7a-43b5-96ca-7ef96be3815e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f2e22e49-ad98-46fc-b3f6-b9815b9ab095"}}}}, {"uuid": "fdebb9b4-7dad-44e1-89fa-07845bbeafad", "name": "55c9250e-e64e-4954-8dbf-d93791a576e9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1206689642843692, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34257205075767067, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aae121fb-b12e-4312-b17b-f4a5fe5a6853", "name": "04384dfc-7214-4f2b-b449-060dc7a9c122", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fdebb9b4-7dad-44e1-89fa-07845bbeafad"}}}]}, {"uuid": "4c88d4b3-eeee-49c9-8200-c22d72a7e5c1", "name": "load_p1rlv817_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11064c6f-3b7a-43b5-96ca-7ef96be3815e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aae121fb-b12e-4312-b17b-f4a5fe5a6853"}}}}, {"uuid": "6cfcc2d1-35cc-4487-9fad-d776a52e44a4", "name": "546d460b-d910-4839-bab8-8fa5e7633188_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6669289783709, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.056901546523703654, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "03355bda-6ec3-41d7-bd7e-561878806338", "name": "7515a17d-db96-49cb-92eb-82f1034f0bfb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6cfcc2d1-35cc-4487-9fad-d776a52e44a4"}}}]}, {"uuid": "4dfc5955-660e-4595-a330-c040395a985c", "name": "load_p1rlv818_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd8c54fd-14d4-46fa-8bef-59c1097d5026"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "03355bda-6ec3-41d7-bd7e-561878806338"}}}}, {"uuid": "22c85500-9369-41ae-b2fd-df9cf5491168", "name": "c0d8a78f-2c84-47e6-a6f1-4539baf2a4c1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6669289783709, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.056901546523703654, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5ec7b202-9be4-4f06-90dd-c373fd66e271", "name": "18450587-18dd-495a-b503-26c3b7666697", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "22c85500-9369-41ae-b2fd-df9cf5491168"}}}]}, {"uuid": "5b11581f-6f3b-4e07-9631-582873c4ad2d", "name": "load_p1rlv818_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd8c54fd-14d4-46fa-8bef-59c1097d5026"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5ec7b202-9be4-4f06-90dd-c373fd66e271"}}}}, {"uuid": "29b9d5df-74fd-4d30-b8db-b1dc6baf59c5", "name": "700c68e8-f6bd-4e87-83ee-f0234d7744c5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.195601026095605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4379463760124337, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fe86b1ac-9749-4799-8245-57e5a38f23cb", "name": "01909453-2a47-428b-95f7-da66d28dbf70", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "29b9d5df-74fd-4d30-b8db-b1dc6baf59c5"}}}]}, {"uuid": "89ca12ad-7ca6-44eb-844b-402ac986d9ed", "name": "load_p1rlv819_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "def7e507-cb62-42f5-8451-b8a742ef4eb2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fe86b1ac-9749-4799-8245-57e5a38f23cb"}}}}, {"uuid": "2c2b7e63-bd59-4911-9dff-b60fb2ca9df0", "name": "9d2c38c2-cc88-474b-97b5-d32bf1220fb9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.195601026095605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4379463760124337, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9d7081f1-3610-4720-83ee-674d84afb519", "name": "deb735ed-88c7-483c-972c-ef5226dc0706", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2c2b7e63-bd59-4911-9dff-b60fb2ca9df0"}}}]}, {"uuid": "2360163a-c6ae-4a56-8b0f-268bf5d7f355", "name": "load_p1rlv819_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "def7e507-cb62-42f5-8451-b8a742ef4eb2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9d7081f1-3610-4720-83ee-674d84afb519"}}}}, {"uuid": "359e99f9-c749-4a63-9430-3d7d1687bf3a", "name": "dc8fcfe6-1b8d-4b27-9304-228eafb3bea7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.008167500419157, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.871384812064858, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "08081de5-092d-418d-8bf1-7a0776a98115", "name": "d6882342-2d99-4ee8-8620-51e18126df5d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "359e99f9-c749-4a63-9430-3d7d1687bf3a"}}}]}, {"uuid": "61583365-45ef-467f-bb32-f91025a8734e", "name": "load_p1rlv820_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41e1e576-4cc9-4fea-9d87-d436f000a675"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "08081de5-092d-418d-8bf1-7a0776a98115"}}}}, {"uuid": "2069248f-6ee1-48af-aef7-8148d4d28b60", "name": "f63716d2-ce08-4e7a-984e-76afa17927f9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.008167500419157, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.871384812064858, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2f52cef4-03b0-41b0-9cd8-e2ac77c6d1ca", "name": "f96170a8-efbe-4507-b6e8-ecf270701de9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2069248f-6ee1-48af-aef7-8148d4d28b60"}}}]}, {"uuid": "c8915dd6-3369-4fb4-acb5-5a4cd2081813", "name": "load_p1rlv820_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41e1e576-4cc9-4fea-9d87-d436f000a675"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2f52cef4-03b0-41b0-9cd8-e2ac77c6d1ca"}}}}, {"uuid": "924ed092-c747-45a6-83f1-d75008562baf", "name": "e48461e1-8dc1-479e-b509-d84abb5c5a92_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4363904318707768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7717292253609904, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3f825a39-24df-424e-9e0a-f0438f84d933", "name": "77fe357d-9cfb-4a07-82ac-389991596cde", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "924ed092-c747-45a6-83f1-d75008562baf"}}}]}, {"uuid": "516e8fd2-c4d4-49cd-b34a-7d09cbed8e5c", "name": "load_p1rlv821_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5578d8b4-7c1e-444f-8d27-8c9bf733f420"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3f825a39-24df-424e-9e0a-f0438f84d933"}}}}, {"uuid": "625516ba-61e6-4261-a54c-2f53d81cb1e4", "name": "43a1433d-0afd-42b1-988d-c93b6e2936e8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4363904318707768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7717292253609904, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "93d746a0-40ed-4eeb-a100-03d3b7d228dd", "name": "efadacd5-7018-4c44-8c40-90ffd6627a3e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "625516ba-61e6-4261-a54c-2f53d81cb1e4"}}}]}, {"uuid": "025864c7-1d2b-4f23-a563-57f117b54b95", "name": "load_p1rlv821_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5578d8b4-7c1e-444f-8d27-8c9bf733f420"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "93d746a0-40ed-4eeb-a100-03d3b7d228dd"}}}}, {"uuid": "9f385489-470c-4e4f-82ec-3e20b74fd3df", "name": "c396dca3-3bd5-4b66-8636-2b783f47eabc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3307696614484872, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.07740524652130432, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b108c76f-15e9-4990-af33-62b7addf308b", "name": "69701d81-85c2-43f5-be5e-bee3f7404249", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9f385489-470c-4e4f-82ec-3e20b74fd3df"}}}]}, {"uuid": "8382cc38-6044-45e3-9e0d-62ddfd873277", "name": "load_p1rlv822_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7ce197c-cee4-40df-b1d7-be13f1be8bb1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b108c76f-15e9-4990-af33-62b7addf308b"}}}}, {"uuid": "dd3e4e3a-3559-4027-afba-d627613059c6", "name": "21d52caf-ca54-492b-bc47-fa637a275d66_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3307696614484872, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.07740524652130432, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ba7bb2be-efad-4c03-8020-82c7b135863b", "name": "43163c38-efba-4c0e-9669-cef371ff9323", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dd3e4e3a-3559-4027-afba-d627613059c6"}}}]}, {"uuid": "1e56c001-43d9-4ef4-aa50-f82a1f42232d", "name": "load_p1rlv822_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7ce197c-cee4-40df-b1d7-be13f1be8bb1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ba7bb2be-efad-4c03-8020-82c7b135863b"}}}}, {"uuid": "43c1785d-9bed-4a42-877f-ad25a083d32e", "name": "de719e1f-e982-40a1-9d77-d4931c9ef1fe_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.396349422902612, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13402564403017767, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e5a93594-c464-46e5-94e3-ee0e9672a6f4", "name": "e81a1162-8c21-42ce-8159-51bf411564ae", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "43c1785d-9bed-4a42-877f-ad25a083d32e"}}}]}, {"uuid": "c6e5319e-9f6a-411c-af04-8f7bcbd5054c", "name": "load_p1rlv823_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81802469-7320-47e9-b826-fbb33bd371ab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e5a93594-c464-46e5-94e3-ee0e9672a6f4"}}}}, {"uuid": "732af354-3640-4143-8ab9-7f60cd75a7cb", "name": "67f449d4-29d0-41e9-926a-721a49b03abe_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.396349422902612, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13402564403017767, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e9e0b6ba-dd5c-4271-b788-e17debd0e9c1", "name": "99758b48-4b27-4629-9166-a329db484aa3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "732af354-3640-4143-8ab9-7f60cd75a7cb"}}}]}, {"uuid": "e28c0ad6-88fe-40ff-a288-8d5abdb44e54", "name": "load_p1rlv823_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81802469-7320-47e9-b826-fbb33bd371ab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e9e0b6ba-dd5c-4271-b788-e17debd0e9c1"}}}}, {"uuid": "ae0714a0-73be-4bae-8c83-bc9c9fa06ecf", "name": "6dcc93be-02a0-41ac-967f-e1079869c476_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2520868864654517, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.447133871274774, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7a24802e-526b-47a6-9ca6-2663b791840e", "name": "fd57d0f7-5105-4000-a96c-fa2643f11a48", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ae0714a0-73be-4bae-8c83-bc9c9fa06ecf"}}}]}, {"uuid": "7481a3f9-8384-48c9-9635-ee667876d70b", "name": "load_p1rlv824_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20ce76b6-9305-4525-b77e-b7300edc2c81"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7a24802e-526b-47a6-9ca6-2663b791840e"}}}}, {"uuid": "02a872db-8965-4030-be6c-e5eba07a0186", "name": "3bc89a2e-df99-411e-bfd7-7b60f6a0df53_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2520868864654517, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.447133871274774, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2d7c4db9-f57c-4683-9f7a-326a08a232cb", "name": "273da339-2e96-45f0-bf5a-361c5fabb759", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "02a872db-8965-4030-be6c-e5eba07a0186"}}}]}, {"uuid": "2da7ec48-a219-4860-b157-b952d788b1fd", "name": "load_p1rlv824_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20ce76b6-9305-4525-b77e-b7300edc2c81"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2d7c4db9-f57c-4683-9f7a-326a08a232cb"}}}}, {"uuid": "c25e60ea-748b-4dc8-91bd-11ba47a59b90", "name": "7705d927-687f-472f-9f3f-97f76e32d931_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.107858967059457, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3651352875232526, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ed082447-de8b-4db0-bcac-8321cd5b5865", "name": "dc510fb5-a27f-499e-aec2-85cfc57e665c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c25e60ea-748b-4dc8-91bd-11ba47a59b90"}}}]}, {"uuid": "1f09f953-cee0-45a4-a758-5408113a1b67", "name": "load_p1rlv825_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d209dff6-7a24-41ef-947a-8c6f79c2d65c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ed082447-de8b-4db0-bcac-8321cd5b5865"}}}}, {"uuid": "b148e492-bf6a-4644-97ab-97692805a008", "name": "4c356a34-1433-4277-8245-e8dd31188a15_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.107858967059457, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3651352875232526, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bd5e69ea-8e7b-4aa2-a197-465d10b3de6c", "name": "a23ea15f-02e5-4161-83df-0f68f951e1f5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b148e492-bf6a-4644-97ab-97692805a008"}}}]}, {"uuid": "2eae6474-5984-44cd-b557-74368e1ba0e5", "name": "load_p1rlv825_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d209dff6-7a24-41ef-947a-8c6f79c2d65c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bd5e69ea-8e7b-4aa2-a197-465d10b3de6c"}}}}, {"uuid": "6c33c342-8e5a-488a-b638-33e7ed70acb4", "name": "4d3811cd-4607-4ed9-b2a6-97940954c71a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.253869376169332, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.6228339639204339, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ce4c46dc-0f47-4985-bcbb-c278f75f57e5", "name": "820dcb99-deb3-45f7-8924-45da135769cc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c33c342-8e5a-488a-b638-33e7ed70acb4"}}}]}, {"uuid": "e1d6bb83-68ec-4e1c-8e31-96aaa50a140b", "name": "load_p1rlv826_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06746d4d-3db8-45b1-888e-d3d9e405ccaf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ce4c46dc-0f47-4985-bcbb-c278f75f57e5"}}}}, {"uuid": "a561e955-6cdb-4877-92b3-76a511ec69dd", "name": "6907b347-f27e-4119-81ce-258996b075ab_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.253869376169332, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.6228339639204339, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4d9d58e4-826f-4533-976a-07a74519c72c", "name": "5336a82c-6365-4ec0-808d-6e5f1c778f25", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a561e955-6cdb-4877-92b3-76a511ec69dd"}}}]}, {"uuid": "57fb6b3f-38b0-4c6b-896e-e458a17c2e13", "name": "load_p1rlv826_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06746d4d-3db8-45b1-888e-d3d9e405ccaf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4d9d58e4-826f-4533-976a-07a74519c72c"}}}}, {"uuid": "59863883-9c7c-4105-aad3-649bc7f1c86c", "name": "42a04cbe-98b1-4573-bbdb-a4ed8fefdb84_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7037919474579788, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6943112548118018, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a0da3511-7362-46bb-ad2b-e10a83884207", "name": "ba8319d8-b6c4-4d55-8ecd-2d7863eaa07c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "59863883-9c7c-4105-aad3-649bc7f1c86c"}}}]}, {"uuid": "97e3d9fc-8e5e-4414-b212-0538210a1add", "name": "load_p1rlv827_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c89db91-40fe-4de6-973e-5d8c23e35080"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a0da3511-7362-46bb-ad2b-e10a83884207"}}}}, {"uuid": "983a7419-bc91-4c68-9e29-fbe68f06fe48", "name": "1f6e40aa-31bc-4190-91b8-d783c587d4fe_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7037919474579788, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6943112548118018, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a361842b-d762-4198-ade6-c746a872ea4f", "name": "30b629ce-6a69-4159-996f-c797e585ae37", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "983a7419-bc91-4c68-9e29-fbe68f06fe48"}}}]}, {"uuid": "06acf64c-354f-444c-bf0c-99db6ed05d02", "name": "load_p1rlv827_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c89db91-40fe-4de6-973e-5d8c23e35080"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a361842b-d762-4198-ade6-c746a872ea4f"}}}}, {"uuid": "c0da35c7-38c3-4a5f-b49c-fd926354dc45", "name": "629fac6e-d544-4445-869f-cd6d0ef5e52c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8668291909105112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7572719732007044, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7fd263c3-70d0-417c-9a9f-204208d60db4", "name": "40370cd1-6e63-4ebf-a139-9431d9e4f6a0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c0da35c7-38c3-4a5f-b49c-fd926354dc45"}}}]}, {"uuid": "0667d89d-8655-4719-910e-b5c90e028e24", "name": "load_p1rlv828_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08c3f5ef-c2d5-4ce2-8fc7-b665d8cbbab6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7fd263c3-70d0-417c-9a9f-204208d60db4"}}}}, {"uuid": "cc6c55e1-5bfe-48df-8608-a17fa1321933", "name": "3959c432-385d-4a8d-89c9-41cd743eb8ca_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8668291909105112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7572719732007044, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "214e9093-d512-4c67-bf8a-ef70b8086f41", "name": "cbd2b3d4-fd43-4096-8e91-63b2907967d8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cc6c55e1-5bfe-48df-8608-a17fa1321933"}}}]}, {"uuid": "ea5bcc31-c953-4505-8c46-60511b2f876e", "name": "load_p1rlv828_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08c3f5ef-c2d5-4ce2-8fc7-b665d8cbbab6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "214e9093-d512-4c67-bf8a-ef70b8086f41"}}}}, {"uuid": "7ad6bc0c-b62f-44ae-9c37-ab3b4052d7c8", "name": "f30d3093-c727-47e3-baba-93875c057f3e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7400090938863744, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.257745187793523, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "401a8519-192c-42da-a41a-bdad27ed8419", "name": "0aa20863-91fe-49fe-a3ed-41231982e601", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7ad6bc0c-b62f-44ae-9c37-ab3b4052d7c8"}}}]}, {"uuid": "0ff83211-0502-4e70-a369-18a16f4ae90c", "name": "load_p1rlv829_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e3a1bd0-69fe-42bb-993d-2094ecc658ce"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "401a8519-192c-42da-a41a-bdad27ed8419"}}}}, {"uuid": "a4bf3895-2bb5-4ee3-8cfe-2e09c907fd8c", "name": "e6fa068a-bf15-4d7d-8332-e191453e2acd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7400090938863744, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.257745187793523, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eb8fdc59-30ac-483d-9df4-0dec6bb85ceb", "name": "7740e9e8-162d-4b41-8c1a-212cea502eb9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a4bf3895-2bb5-4ee3-8cfe-2e09c907fd8c"}}}]}, {"uuid": "299e04bb-1d60-423e-8d18-56645cf724fc", "name": "load_p1rlv829_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e3a1bd0-69fe-42bb-993d-2094ecc658ce"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eb8fdc59-30ac-483d-9df4-0dec6bb85ceb"}}}}, {"uuid": "91821f0d-42c1-443d-bab5-f4dbfa137736", "name": "6d6ba518-b330-41aa-8db4-9eee5d01dcf6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9541125560071345, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3732603805546264, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9608867c-46ad-4f6e-bad2-a4ebf473085b", "name": "03eaea5d-cfcd-4011-9944-96a383b5746f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "91821f0d-42c1-443d-bab5-f4dbfa137736"}}}]}, {"uuid": "b9160f40-3f3a-4063-b2c5-28972fb67dcc", "name": "load_p1rlv830_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b7538477-32ab-4db6-872d-83be7ec89fd9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9608867c-46ad-4f6e-bad2-a4ebf473085b"}}}}, {"uuid": "faae66b1-94b7-4b3f-a513-844e1d4e3b59", "name": "d939b1ac-1f94-4ebf-833e-d6c7748a8701_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9541125560071345, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3732603805546264, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "22ba8929-046b-4dda-a245-91697081fac6", "name": "b88128e3-e68d-4911-a40b-e6b57028509d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "faae66b1-94b7-4b3f-a513-844e1d4e3b59"}}}]}, {"uuid": "c080c3d3-8276-4554-85db-b92e863ffa05", "name": "load_p1rlv830_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b7538477-32ab-4db6-872d-83be7ec89fd9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "22ba8929-046b-4dda-a245-91697081fac6"}}}}, {"uuid": "610b56f9-d801-45ae-91db-df6cf2d35a48", "name": "853c8726-a620-4d7a-90e1-56e680eb8707_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.746284303820433, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6724067157838972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5ef1cd69-1981-4100-ae90-f109a7a00c4e", "name": "e3db4086-7eaf-4569-aff4-b6855d4845ff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "610b56f9-d801-45ae-91db-df6cf2d35a48"}}}]}, {"uuid": "717c1f69-4334-47b0-9273-fe51d52e1411", "name": "load_p1rlv831_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4b6c4e-78d0-4c8e-907c-619f1e43c149"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5ef1cd69-1981-4100-ae90-f109a7a00c4e"}}}}, {"uuid": "67766f61-4a1d-4ae4-949d-345e1fa00a3b", "name": "f577a9b9-c12a-4073-8d3b-edfaeceec0a7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.746284303820433, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6724067157838972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b309dd9b-3303-4986-bf5d-7b6a9125fbfa", "name": "30b217c3-5083-4f0f-83d1-5a83ff59cdec", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "67766f61-4a1d-4ae4-949d-345e1fa00a3b"}}}]}, {"uuid": "a9025d91-ecf5-40e7-a428-35f87c18338b", "name": "load_p1rlv831_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4b6c4e-78d0-4c8e-907c-619f1e43c149"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b309dd9b-3303-4986-bf5d-7b6a9125fbfa"}}}}, {"uuid": "afc3c4de-ab14-43a4-8d9e-9707108c6cb5", "name": "6bee1ada-96fe-4d3d-81f5-c1d0a73bad25_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.250267265771566, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8009319586825154, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ac573839-6e5c-4f36-9a7b-539fa20cd575", "name": "d8c6d513-2c81-4cfe-a307-6e39d448e951", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "afc3c4de-ab14-43a4-8d9e-9707108c6cb5"}}}]}, {"uuid": "0b4ab97a-46d5-4222-be17-9a01904cb32e", "name": "load_p1rlv832_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10373c0d-6a3c-4160-a174-22de447d4c38"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ac573839-6e5c-4f36-9a7b-539fa20cd575"}}}}, {"uuid": "7229411d-e4f1-4f2b-99a0-e7ba1ae18b31", "name": "35c3f57a-bf1f-413d-ad43-41a74ca34e27_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.250267265771566, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8009319586825154, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8b0cd29d-184f-4521-ad39-ea089bf07926", "name": "24c33887-3572-4423-9d5b-cdf7de2cbe5b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7229411d-e4f1-4f2b-99a0-e7ba1ae18b31"}}}]}, {"uuid": "7ba46c6f-ba1c-47d7-9b7a-06e1e5719ae1", "name": "load_p1rlv832_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10373c0d-6a3c-4160-a174-22de447d4c38"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8b0cd29d-184f-4521-ad39-ea089bf07926"}}}}, {"uuid": "9e1344e8-665f-4802-bc78-adc16aec041a", "name": "2bccc6c8-546c-4581-b75f-badf5b5cb7d4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1212324580541053, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5100712782164012, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2651276c-e3e2-4864-afc8-1da4343802b9", "name": "f3efb4cd-794e-4529-9c3c-341c54217828", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9e1344e8-665f-4802-bc78-adc16aec041a"}}}]}, {"uuid": "21b607ba-0654-4239-be2d-fadce2328dd7", "name": "load_p1rlv833_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eb57fc4-636d-4923-9f4a-d308b062599f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2651276c-e3e2-4864-afc8-1da4343802b9"}}}}, {"uuid": "f12af18a-47fa-47d1-a761-95ec62686d35", "name": "9886c5ae-49a6-4fa0-b833-409938e3701e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1212324580541053, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5100712782164012, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "49bcbe3a-fe71-406c-a18b-38410946c071", "name": "624ef648-caab-4363-9633-a4af7656fbae", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f12af18a-47fa-47d1-a761-95ec62686d35"}}}]}, {"uuid": "3dfe3a27-efa3-4260-a84f-c3af41c6c947", "name": "load_p1rlv833_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eb57fc4-636d-4923-9f4a-d308b062599f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "49bcbe3a-fe71-406c-a18b-38410946c071"}}}}, {"uuid": "828de88b-2da7-4949-a09d-a7e48e037427", "name": "fe52519e-3b08-4cdc-8dff-5c6c8dea6a26_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.107858967059457, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3651352875232526, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f2fbfcd4-8d69-47a6-af51-318cfac95969", "name": "1c968931-2b64-4deb-8271-85610cbaf286", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "828de88b-2da7-4949-a09d-a7e48e037427"}}}]}, {"uuid": "0d46b9b6-70f9-43ca-8440-b4e9bad211fa", "name": "load_p1rlv834_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d437c83c-cbd1-41bf-b455-21123e82d59f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f2fbfcd4-8d69-47a6-af51-318cfac95969"}}}}, {"uuid": "15c45dba-5e69-4c70-b57e-2ee55683f89b", "name": "bce8a9a9-d325-4088-bed5-f1e9efafb067_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.107858967059457, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3651352875232526, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b25d3f8b-b0bc-49a0-bbc9-2b0517ac3c39", "name": "04c293e5-c570-4ee9-be1c-98e3b93fcdd0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "15c45dba-5e69-4c70-b57e-2ee55683f89b"}}}]}, {"uuid": "56510e77-31ae-4502-8883-767e359af33c", "name": "load_p1rlv834_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d437c83c-cbd1-41bf-b455-21123e82d59f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b25d3f8b-b0bc-49a0-bbc9-2b0517ac3c39"}}}}, {"uuid": "308e0b97-6215-4e63-aecc-72d5a156ebd0", "name": "b591c622-741a-4b41-966e-7b0e3ac368f4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1426015471760884, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5928311844731246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "646a7475-4643-4898-805a-75f320668a09", "name": "7680aef7-bdbe-4eed-89a3-72d8d86ee122", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "308e0b97-6215-4e63-aecc-72d5a156ebd0"}}}]}, {"uuid": "f54d8273-6c0f-48c5-9266-581a386820c2", "name": "load_p1rlv835_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bc35476-5839-4095-bea5-36e32450b890"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "646a7475-4643-4898-805a-75f320668a09"}}}}, {"uuid": "a9b9efc3-5b10-4a82-ae2f-6772a746aa4d", "name": "7c4c87bf-59d0-4f19-a53d-841f529cb164_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1426015471760884, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5928311844731246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "657e4375-2b1e-420b-8447-a12cd7246c24", "name": "e6529a33-34f4-4c52-920d-4fbf92b78d5d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a9b9efc3-5b10-4a82-ae2f-6772a746aa4d"}}}]}, {"uuid": "8858b368-17f9-43a7-895a-67d5d3a09b35", "name": "load_p1rlv835_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bc35476-5839-4095-bea5-36e32450b890"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "657e4375-2b1e-420b-8447-a12cd7246c24"}}}}, {"uuid": "6b543206-afcc-4053-af5a-60eae057d2dd", "name": "9f53b4f5-d81a-4842-bb37-dab765efb4a0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.941898785419248, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8498359578625553, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "17c99f84-2e3f-4355-afd0-0e5d869deccb", "name": "9bd960e5-1579-4c69-a241-2c964d985a09", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6b543206-afcc-4053-af5a-60eae057d2dd"}}}]}, {"uuid": "625a15f2-f4b1-4664-becf-522994dfcc67", "name": "load_p1rlv836_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12556ab7-c50a-4624-9d84-b85585822245"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "17c99f84-2e3f-4355-afd0-0e5d869deccb"}}}}, {"uuid": "18b48cec-54f1-4030-8722-dc2c86f02589", "name": "bb4b9f21-c379-4328-9541-8879c5c3f1e8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.941898785419248, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8498359578625553, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5f7fb70e-fa24-40c4-b113-ee644f4111bd", "name": "424ea7c6-2b33-4b83-88f3-23b0ef04e6d9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "18b48cec-54f1-4030-8722-dc2c86f02589"}}}]}, {"uuid": "b434d51d-ba3f-4122-87f2-6ff564f6efdc", "name": "load_p1rlv836_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12556ab7-c50a-4624-9d84-b85585822245"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5f7fb70e-fa24-40c4-b113-ee644f4111bd"}}}}, {"uuid": "15ca6d0b-f87e-47b7-9e40-dab53f7172ed", "name": "745a9d60-cfb1-4af2-b253-0383da07e4e7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4663769608466568, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5502546109327153, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e1a94eab-8ce7-4787-b6c2-86c56ef4334e", "name": "48636bca-59fb-48b8-bdf7-303c97e0d622", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "15ca6d0b-f87e-47b7-9e40-dab53f7172ed"}}}]}, {"uuid": "8c7dd958-fab7-4776-90a0-0cc111dc9d1e", "name": "load_p1rlv837_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33492e0f-c907-46c6-a529-503480b642bb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e1a94eab-8ce7-4787-b6c2-86c56ef4334e"}}}}, {"uuid": "c813fd7f-5cc8-44e7-b411-b841482231f8", "name": "d0cf8302-c91b-43e5-90ed-f81efb1848d5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4663769608466568, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5502546109327153, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d004d951-a13f-4dfc-bbf9-e685e2ba6ccb", "name": "5659efd3-414f-444b-aaa0-0aa0e9454b67", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c813fd7f-5cc8-44e7-b411-b841482231f8"}}}]}, {"uuid": "5744bba1-a670-436a-b29c-c45ce46cfe5c", "name": "load_p1rlv837_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33492e0f-c907-46c6-a529-503480b642bb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d004d951-a13f-4dfc-bbf9-e685e2ba6ccb"}}}}, {"uuid": "e59167f2-ae8c-484a-aed5-6e7518c1e6b6", "name": "f76b109d-e72b-427d-a9aa-b13a297e3018_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3464174292990054, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8802812503815668, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "62c8c8bb-5f9f-42fe-9919-7742b22a5265", "name": "c92d20d8-9859-482f-82c6-033771a0b76b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e59167f2-ae8c-484a-aed5-6e7518c1e6b6"}}}]}, {"uuid": "20ab6f62-5c4e-4508-90ad-6fe1a71ab34a", "name": "load_p1rlv838_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7ffe87d-4424-4495-83c1-6765d385207c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "62c8c8bb-5f9f-42fe-9919-7742b22a5265"}}}}, {"uuid": "c82016b9-e40e-4e2a-b866-4c0541f9db78", "name": "adeda6f9-bfa2-4159-8b66-912227216c35_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3464174292990054, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8802812503815668, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ff51bfab-4d8d-4e23-9397-b7eb2553ca6e", "name": "e31a30f3-80b5-43ae-b498-a38eb7e2f8db", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c82016b9-e40e-4e2a-b866-4c0541f9db78"}}}]}, {"uuid": "a0507800-213a-4e03-b02b-72090c6c2e93", "name": "load_p1rlv838_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7ffe87d-4424-4495-83c1-6765d385207c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ff51bfab-4d8d-4e23-9397-b7eb2553ca6e"}}}}, {"uuid": "8791ab4c-c618-4962-a1ef-ae457fefd9f1", "name": "b7168462-c24d-43bb-b983-55d3b9b9c877_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3086582709384027, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12628327836733033, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0d61d9c4-026e-44a3-9fc9-57e3a534a981", "name": "8b80649c-86e8-4ea2-9fc4-c25a8da3d6ae", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8791ab4c-c618-4962-a1ef-ae457fefd9f1"}}}]}, {"uuid": "5c2fe452-6368-42d8-b1f6-801d4285f1e9", "name": "load_p1rlv839_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48e97be9-1f80-457f-a56e-79f54458c620"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0d61d9c4-026e-44a3-9fc9-57e3a534a981"}}}}, {"uuid": "e9891289-6645-40d0-b3f4-3fe938d4bf4f", "name": "a9c3ba8d-6e50-4b4b-b2ee-49b081413bb5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3086582709384027, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12628327836733033, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "709a13e8-7896-411c-8060-b8656b4b1b2d", "name": "079e76c7-3459-47d4-b774-90bfc1ec9ccd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e9891289-6645-40d0-b3f4-3fe938d4bf4f"}}}]}, {"uuid": "2a329d21-97c6-47ac-a98c-2406bd17b0cc", "name": "load_p1rlv839_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48e97be9-1f80-457f-a56e-79f54458c620"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "709a13e8-7896-411c-8060-b8656b4b1b2d"}}}}, {"uuid": "01bc638c-a479-4e7d-805a-d7137f576946", "name": "eafe6c48-c593-468e-880b-d8c42d7e1e87_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4950137537296666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31506625700854357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "de546a87-f52b-4343-b6d8-ee5fdc026203", "name": "d42df018-de45-407f-9f08-2f702c2f0468", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "01bc638c-a479-4e7d-805a-d7137f576946"}}}]}, {"uuid": "990c975d-7dac-4138-ae0e-698b5d9d1b39", "name": "load_p1rlv840_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "024961c3-25f4-4a15-a52a-7f88dc652766"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "de546a87-f52b-4343-b6d8-ee5fdc026203"}}}}, {"uuid": "ec04d3e5-797c-48a5-8ab7-57dd0a77a3c9", "name": "9f29c20c-d852-4c24-877d-0bbb7058be6c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4950137537296666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31506625700854357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f42e8ec-3919-43ad-9346-b9ee5da3f499", "name": "4332240a-aa4d-464f-88a9-7b0f4ae0b295", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ec04d3e5-797c-48a5-8ab7-57dd0a77a3c9"}}}]}, {"uuid": "ab9f5e05-2970-4924-8a85-aae4fe263b3e", "name": "load_p1rlv840_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "024961c3-25f4-4a15-a52a-7f88dc652766"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f42e8ec-3919-43ad-9346-b9ee5da3f499"}}}}, {"uuid": "9785cfe5-256a-486d-a324-1bd5f30a5e19", "name": "1702e774-78fc-4206-b45b-14bb4f2aa4ba_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9614713621548963, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.170985110067395, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "475962a7-6780-4135-86e3-009d5d683a6b", "name": "7ca65b02-a7da-434d-9c31-f495b72c312c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9785cfe5-256a-486d-a324-1bd5f30a5e19"}}}]}, {"uuid": "cfa6d704-c332-44d1-ba2e-31172bba49da", "name": "load_p1rlv841_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eb6c1b4-f09a-44a5-a13f-64051183736d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "475962a7-6780-4135-86e3-009d5d683a6b"}}}}, {"uuid": "8f3aa178-a4a2-4884-b53f-a8f2409614ba", "name": "16a86396-039a-474c-aa5f-a2e098358315_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9614713621548963, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.170985110067395, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "04943b34-4a8a-422e-aef7-d4470dc9b981", "name": "2c38238e-59a3-4fd1-93ff-671ebc712e95", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8f3aa178-a4a2-4884-b53f-a8f2409614ba"}}}]}, {"uuid": "e7720fb8-1f33-4c47-be4b-88e5a430b611", "name": "load_p1rlv841_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eb6c1b4-f09a-44a5-a13f-64051183736d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "04943b34-4a8a-422e-aef7-d4470dc9b981"}}}}, {"uuid": "b7af79f8-1862-46b0-b51f-0c825baf15d9", "name": "64556f90-f1e4-4e44-a053-a9d536fb1e79_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8285317723273034, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9836303634928509, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "48ca5f56-bf1f-45f8-b8bb-9b040ded4573", "name": "0b6cf306-da1f-4286-a5a2-521ba012fd54", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b7af79f8-1862-46b0-b51f-0c825baf15d9"}}}]}, {"uuid": "0940874a-e752-42c9-90ae-e7be990bb853", "name": "load_p1rlv842_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8f304a4-6e39-4288-9b9b-e41bb37c6019"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "48ca5f56-bf1f-45f8-b8bb-9b040ded4573"}}}}, {"uuid": "627dcd89-b96d-4c13-8abd-b98c9111fd73", "name": "df20d7e6-68c2-4695-b4f1-fa4ca288c8dc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8285317723273034, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9836303634928509, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8ba1a638-dfb0-4e1d-b530-78df11b9d5f1", "name": "cb3c7422-da41-45c7-9a9d-993d5a4a6897", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "627dcd89-b96d-4c13-8abd-b98c9111fd73"}}}]}, {"uuid": "cb3eaf0a-c353-43bc-94b1-764ed209ad42", "name": "load_p1rlv842_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8f304a4-6e39-4288-9b9b-e41bb37c6019"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8ba1a638-dfb0-4e1d-b530-78df11b9d5f1"}}}}, {"uuid": "9829bdca-2176-4d31-8c70-d08643ab2027", "name": "59648600-ec8c-4903-afae-2622087f494a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7943609059660943, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8824322096654456, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b701fec3-1eb1-4beb-b725-fb95c0b2c7c7", "name": "86103c0d-dcad-49b9-aa08-f4b555bae597", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9829bdca-2176-4d31-8c70-d08643ab2027"}}}]}, {"uuid": "13454edd-3943-4d68-9ce7-b08db819335a", "name": "load_p1rlv843_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3bc013f-c78d-4a3c-b27f-826c3025de0e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b701fec3-1eb1-4beb-b725-fb95c0b2c7c7"}}}}, {"uuid": "36e9cb2d-c336-43c7-958f-597584a7b4d6", "name": "ce8e56f3-a73d-41f0-97db-1f768e25f537_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7943609059660943, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8824322096654456, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c4a7ab30-c1ad-4ce7-97b2-2604f23ea4f3", "name": "6a5bd58b-6aba-407c-9d12-4cc182b603fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "36e9cb2d-c336-43c7-958f-597584a7b4d6"}}}]}, {"uuid": "eb0a4e99-8354-47ec-a036-a49ce41f9bcc", "name": "load_p1rlv843_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3bc013f-c78d-4a3c-b27f-826c3025de0e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c4a7ab30-c1ad-4ce7-97b2-2604f23ea4f3"}}}}, {"uuid": "ffa75d2e-5c98-4afa-b23b-f70dd0be73a3", "name": "ed64f055-1c53-4159-a244-06b2e908e817_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.062987656442733, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.2699236524876967, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ca2f73cf-b69b-4011-ab51-ca490b35fd76", "name": "3facab19-f51f-47e3-b137-1a3803f920ee", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ffa75d2e-5c98-4afa-b23b-f70dd0be73a3"}}}]}, {"uuid": "946b5b25-8afa-4bde-9b2a-c736d884eec9", "name": "load_p1rlv844_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26294827-db76-40b6-b652-1e41efdf15dc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ca2f73cf-b69b-4011-ab51-ca490b35fd76"}}}}, {"uuid": "c6f6f984-64c4-4396-89fd-c9c47042fc28", "name": "b62398c0-d470-441b-a912-a47fced3a655_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.062987656442733, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.2699236524876967, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "28fc005b-75dd-46c7-b9db-d5e8c6127aa1", "name": "772310ab-cafb-49ea-8f32-60a74196f0f6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c6f6f984-64c4-4396-89fd-c9c47042fc28"}}}]}, {"uuid": "a7e0dcd0-a7c6-4adb-b88f-f492af62b272", "name": "load_p1rlv844_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26294827-db76-40b6-b652-1e41efdf15dc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "28fc005b-75dd-46c7-b9db-d5e8c6127aa1"}}}}, {"uuid": "b4003b35-2b3b-4af0-8de4-604977581c97", "name": "8cb5ff7f-5aef-42bf-9119-a05dad52b9f9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.910200682298975, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5555412020426419, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ab226e6d-82fd-41e8-b993-5b84b51eb4ff", "name": "39b0862f-feb7-4da5-885d-73d78e073189", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b4003b35-2b3b-4af0-8de4-604977581c97"}}}]}, {"uuid": "8376fc1a-b59f-43cb-a5a8-44d0b44d29ab", "name": "load_p1rlv845_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b053d449-b15b-4292-9a73-9b7d104a8e38"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ab226e6d-82fd-41e8-b993-5b84b51eb4ff"}}}}, {"uuid": "c3958938-cbd3-472a-9c99-95806bb84b3f", "name": "f59a083b-e6d9-4685-aeb1-0cf60622c86e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.910200682298975, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5555412020426419, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "00461c76-6c87-4612-bc51-1d0989527a7b", "name": "0c09ca8e-8769-4600-a588-90eca8873146", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c3958938-cbd3-472a-9c99-95806bb84b3f"}}}]}, {"uuid": "d0b71404-56b4-4fe4-ab8d-b5cf552f66b9", "name": "load_p1rlv845_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b053d449-b15b-4292-9a73-9b7d104a8e38"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "00461c76-6c87-4612-bc51-1d0989527a7b"}}}}, {"uuid": "a55e9cf6-429f-4c71-87de-16ec31853880", "name": "a262e4df-1fef-433b-9ab9-abd8ae469f43_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.772705532239135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.33568286747913667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fa5a99e8-9d11-4954-acc6-47fc1451bbac", "name": "4fcfc64d-9655-48a4-9536-f39ed0b9f374", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a55e9cf6-429f-4c71-87de-16ec31853880"}}}]}, {"uuid": "638ffa96-1e7e-4d99-8bee-907f52cbcc88", "name": "load_p1rlv846_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "145d3757-ca09-45ca-9199-465b6b43fbb7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fa5a99e8-9d11-4954-acc6-47fc1451bbac"}}}}, {"uuid": "2929e2ac-0e30-46eb-b71b-5364e978fe8d", "name": "8365ebed-ff8a-4203-a100-4913109d1bdd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.772705532239135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.33568286747913667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fb5a7159-cbc6-49b0-b1cb-ebcc1dec4b1a", "name": "f5d2c0ae-6b91-4a0b-8817-e22c4ba36710", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2929e2ac-0e30-46eb-b71b-5364e978fe8d"}}}]}, {"uuid": "fec9c5f7-9aa9-48ac-92b1-e3d93fee3c65", "name": "load_p1rlv846_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "145d3757-ca09-45ca-9199-465b6b43fbb7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fb5a7159-cbc6-49b0-b1cb-ebcc1dec4b1a"}}}}, {"uuid": "fa3f6062-4671-4203-8049-c4fad65a9237", "name": "5ecc8f7c-532c-4803-93d5-a8b2ff8bf3aa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2075389461119934, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3167249782629938, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "33d3cde7-a420-435c-8b91-31dfe50c2860", "name": "50247295-4690-4540-bb6a-ccbbdb6d5bf7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fa3f6062-4671-4203-8049-c4fad65a9237"}}}]}, {"uuid": "9c473154-b8b2-4064-9a6a-89dc5a54b69f", "name": "load_p1rlv847_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "283142ff-4884-4adc-9d4c-f8615505415a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "33d3cde7-a420-435c-8b91-31dfe50c2860"}}}}, {"uuid": "c9fc333b-5a54-4b28-a6d4-cd6ccdfe2b6b", "name": "53b25bbb-72d0-4a3d-86a3-0fa55219cfd3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2075389461119934, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3167249782629938, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "969e7e4a-dd5b-46ae-b883-2eb2b40f848b", "name": "e35fb445-415a-4951-853a-47d951f12a41", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9fc333b-5a54-4b28-a6d4-cd6ccdfe2b6b"}}}]}, {"uuid": "14a2504d-01b8-4aac-8748-b0376320ab33", "name": "load_p1rlv847_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "283142ff-4884-4adc-9d4c-f8615505415a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "969e7e4a-dd5b-46ae-b883-2eb2b40f848b"}}}}, {"uuid": "c09d2a7a-d38b-4a5f-86b4-9aea3f3f91b7", "name": "cb6907ad-7410-4473-b3f4-3da1ba202a27_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4794755457968312, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.46197673612457824, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6d3e07b4-1a35-48c9-8adc-6f52113102d6", "name": "e8755510-0e03-4a73-9cce-6b4a79f27838", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c09d2a7a-d38b-4a5f-86b4-9aea3f3f91b7"}}}]}, {"uuid": "4ebbbbb3-7e08-4715-aceb-51a122998f2f", "name": "load_p1rlv848_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e484d77-29ac-4903-afa3-f677283db883"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6d3e07b4-1a35-48c9-8adc-6f52113102d6"}}}}, {"uuid": "51a4e04c-711d-4bd6-8316-c648e2b89856", "name": "6235b454-706d-49e7-ac71-a9344113b912_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4794755457968312, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.46197673612457824, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fd740f4a-7f4c-4795-9bd3-939ec892f916", "name": "d30fa4e9-56e8-4d00-8ca9-0f242173d56f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "51a4e04c-711d-4bd6-8316-c648e2b89856"}}}]}, {"uuid": "5a98bb20-7c07-4b1b-bd7b-d5c289466cf2", "name": "load_p1rlv848_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e484d77-29ac-4903-afa3-f677283db883"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fd740f4a-7f4c-4795-9bd3-939ec892f916"}}}}, {"uuid": "8cab14d9-0a0f-40bf-9b68-d1e2e46939f8", "name": "fd72b7b0-105f-4add-bbd1-d9df40e05337_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.292799122473319, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5385753507809203, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cf07e1f2-31e7-488d-bdb8-479391d57add", "name": "c9581250-75c5-46bd-bb58-d7a7bbd303f7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8cab14d9-0a0f-40bf-9b68-d1e2e46939f8"}}}]}, {"uuid": "4472bb76-70f3-44ff-9d15-46518c7d0d04", "name": "load_p1rlv849_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a95877ca-8600-4e95-82ac-c51cb82acf16"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cf07e1f2-31e7-488d-bdb8-479391d57add"}}}}, {"uuid": "da281240-6876-4756-b99e-99707b3e4b53", "name": "b446a498-18f1-40f2-b50d-fe77f39b60b8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.292799122473319, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5385753507809203, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7e6c224f-9f73-450b-9560-75283650ef2c", "name": "98426f92-904d-4b94-b1e0-99d6c346f267", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "da281240-6876-4756-b99e-99707b3e4b53"}}}]}, {"uuid": "a388bf38-0fb8-4c4b-8736-53457df89b59", "name": "load_p1rlv849_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a95877ca-8600-4e95-82ac-c51cb82acf16"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7e6c224f-9f73-450b-9560-75283650ef2c"}}}}, {"uuid": "079e87a7-2dcf-4c41-82c1-d355db6fd5b7", "name": "da6e5544-3742-4ded-9307-e762416cee5e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.737986692242784, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8906640815201406, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b71072af-4d15-4d1d-bfc9-3edcda196026", "name": "e94dd721-a476-469d-a978-b2f77a3e172c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "079e87a7-2dcf-4c41-82c1-d355db6fd5b7"}}}]}, {"uuid": "b4ac23ec-155a-40fd-85f4-77c43c345631", "name": "load_p1rlv850_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d49057-9c70-4489-95bb-36b5b574e13d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b71072af-4d15-4d1d-bfc9-3edcda196026"}}}}, {"uuid": "c95ac71a-681f-4509-9eba-895a289012d8", "name": "e333efe5-158e-43aa-bdac-155844fbd620_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.737986692242784, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8906640815201406, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "87ddf4da-1542-4022-ad08-cf51913dcf99", "name": "178dc8e1-2375-4a0d-b439-b31c05197025", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c95ac71a-681f-4509-9eba-895a289012d8"}}}]}, {"uuid": "ae73fe56-081e-4996-9bff-d4b073c8dd98", "name": "load_p1rlv850_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d49057-9c70-4489-95bb-36b5b574e13d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "87ddf4da-1542-4022-ad08-cf51913dcf99"}}}}, {"uuid": "938176d6-c264-46f9-b916-44fa987b069a", "name": "2d46fa4e-175e-4ec6-b74d-5dfa3815b18e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6295328634326751, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9988748196040309, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f74787d6-5835-45fa-9290-422bed794f4d", "name": "fa19786d-68d6-4c6a-a062-9235f7c8dfee", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "938176d6-c264-46f9-b916-44fa987b069a"}}}]}, {"uuid": "8a15f266-4f98-4288-8ba5-263a877aeb48", "name": "load_p1rlv851_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48b5535c-f00d-4b48-a23a-87f3f212302f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f74787d6-5835-45fa-9290-422bed794f4d"}}}}, {"uuid": "6b120a3a-f663-4d9f-a57c-ddfd8f2dec4b", "name": "ca2a0e01-00ff-4ef4-aaa5-8aae694aea9f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6295328634326751, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9988748196040309, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fb9087aa-1791-47a4-adeb-a6547ac17b6c", "name": "31097e7a-9eec-4dfa-9a62-3b613bf8bf26", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6b120a3a-f663-4d9f-a57c-ddfd8f2dec4b"}}}]}, {"uuid": "ac397b0f-76ec-4e36-b6c8-415905f2bb6f", "name": "load_p1rlv851_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48b5535c-f00d-4b48-a23a-87f3f212302f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fb9087aa-1791-47a4-adeb-a6547ac17b6c"}}}}, {"uuid": "c2a1f7b5-19ab-47aa-937f-05f52627dddc", "name": "659a36bd-a7aa-4dec-9acf-d31fbb16260a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.072248840478098, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4856137999354615, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f9ad31eb-3ffb-4797-a746-b1604ab4f2b7", "name": "2bdc508a-656f-4100-861f-98a999f72776", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c2a1f7b5-19ab-47aa-937f-05f52627dddc"}}}]}, {"uuid": "32ef83b5-8cc7-4a68-93b8-41764a6abcaa", "name": "load_p1rlv852_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32142941-c546-4356-ba80-123b9128b5de"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f9ad31eb-3ffb-4797-a746-b1604ab4f2b7"}}}}, {"uuid": "86075a23-c51e-49ba-af91-77ff46df6dd3", "name": "01103004-1ff0-4f2c-99f8-3cc408fc55a0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.072248840478098, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4856137999354615, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c6d823a9-35a7-45f1-b243-e78bf6fe23b5", "name": "36396a64-3c5d-4b86-945a-0b3d3cd6d5db", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "86075a23-c51e-49ba-af91-77ff46df6dd3"}}}]}, {"uuid": "ae20b46b-5e41-4a03-9a59-55b7522c841d", "name": "load_p1rlv852_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32142941-c546-4356-ba80-123b9128b5de"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c6d823a9-35a7-45f1-b243-e78bf6fe23b5"}}}}, {"uuid": "96605a2b-6efd-43aa-8a81-f5fc0dba3f0e", "name": "deaf567c-a026-4554-a0a7-687792ab63e9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0307394237991176, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0095205649117913, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "123eebfc-2042-4715-ab91-25732d479e72", "name": "c4872abd-c3bc-4209-8802-bc99fe0f02c3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "96605a2b-6efd-43aa-8a81-f5fc0dba3f0e"}}}]}, {"uuid": "0f13dd75-128f-4674-8647-5b56add5b599", "name": "load_p1rlv853_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "365eff25-8ccb-448b-894f-ad662fe6d684"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "123eebfc-2042-4715-ab91-25732d479e72"}}}}, {"uuid": "8facf6cb-c11b-4172-92b8-83e781a3b8f1", "name": "7cd73183-8983-48c8-b26e-296f3dbe8117_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0307394237991176, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0095205649117913, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "95f41b66-dea3-421b-8f9a-154274c833cf", "name": "9e2d777a-b466-42de-837a-34372aee43f6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8facf6cb-c11b-4172-92b8-83e781a3b8f1"}}}]}, {"uuid": "758828f8-84b9-4627-aa37-55b2e0484323", "name": "load_p1rlv853_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "365eff25-8ccb-448b-894f-ad662fe6d684"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "95f41b66-dea3-421b-8f9a-154274c833cf"}}}}, {"uuid": "717840ac-6dd6-4827-bd43-a554fb72da8c", "name": "d0ee04c6-6faf-4755-9ffa-0969c8e06caf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.621947646480353, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0332384495271123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "64472809-31e9-4821-a8a2-607cb1c44575", "name": "aaa6b3c4-c3d3-457f-b6a7-c3ab9f5eb44e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "717840ac-6dd6-4827-bd43-a554fb72da8c"}}}]}, {"uuid": "9bb9e900-0cbe-480f-b913-d84926db0a02", "name": "load_p1rlv854_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2461b6f0-9a40-4b6f-9669-be479da039f3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "64472809-31e9-4821-a8a2-607cb1c44575"}}}}, {"uuid": "16562700-f4db-4517-abbb-5aa91fff7652", "name": "d3a5a834-ea15-484f-9dde-fcdb1d49033b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.621947646480353, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0332384495271123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cfd37b6d-06db-482a-afb3-8fa4f7a686b5", "name": "411c31b0-e7a3-40e7-adda-02517fe0908e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "16562700-f4db-4517-abbb-5aa91fff7652"}}}]}, {"uuid": "b83a0389-140e-4844-80a2-41f2bffe2b90", "name": "load_p1rlv854_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2461b6f0-9a40-4b6f-9669-be479da039f3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cfd37b6d-06db-482a-afb3-8fa4f7a686b5"}}}}, {"uuid": "f600b2dc-6cdb-4b19-97ad-d56551e79ab4", "name": "e150596e-4503-4ecf-9026-bf049ae0d6fc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.037961707989467, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3691190849967326, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "224dd4bd-f3ff-4f50-97d3-2fdc005e0de3", "name": "ed0f82f0-768d-456c-b6e9-0ee41ce84c6a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f600b2dc-6cdb-4b19-97ad-d56551e79ab4"}}}]}, {"uuid": "7a5ba2e4-3885-4be5-b672-99b3fae2d8c3", "name": "load_p1rlv855_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10611e08-75e2-4422-ac0f-cfb98c7eae4b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "224dd4bd-f3ff-4f50-97d3-2fdc005e0de3"}}}}, {"uuid": "6e323aa2-ba11-48d0-81ef-41387111c606", "name": "eac6cc37-cbe4-4fb4-8a1d-bc90e9fa3754_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.037961707989467, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3691190849967326, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5c3af5ce-5414-41ea-9c5c-89efe6d0d90a", "name": "93900ca9-c875-4baf-81a9-4f3c3d29dace", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6e323aa2-ba11-48d0-81ef-41387111c606"}}}]}, {"uuid": "ceb6e0a6-d1af-4b49-83a3-ec99e79b538f", "name": "load_p1rlv855_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10611e08-75e2-4422-ac0f-cfb98c7eae4b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5c3af5ce-5414-41ea-9c5c-89efe6d0d90a"}}}}, {"uuid": "6df6841e-86ca-4dec-8dcd-4d1e7737d659", "name": "98ba7850-57fc-45a0-b3e0-7d705b57c157_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0599252267318962, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3748861224482183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "84f46b25-5bba-449b-bb71-0fd1708d7b9c", "name": "e9e7e068-991b-428e-bba2-5378e50498cc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6df6841e-86ca-4dec-8dcd-4d1e7737d659"}}}]}, {"uuid": "621bdbbe-256c-4cc9-be75-89226e86b452", "name": "load_p1rlv856_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25f84b28-695b-4d32-b96c-914226444b9f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "84f46b25-5bba-449b-bb71-0fd1708d7b9c"}}}}, {"uuid": "04f372ca-5429-44cc-8e92-039e9872f677", "name": "c7fc900a-9761-4cd4-8341-b345266840fb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0599252267318962, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3748861224482183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1166a1ab-a5b1-456c-8bd7-a71a202292ff", "name": "d9b7e884-83d2-470d-bda2-9909f008c41d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "04f372ca-5429-44cc-8e92-039e9872f677"}}}]}, {"uuid": "ae996b2d-1dea-4f61-99a5-a53fcb898980", "name": "load_p1rlv856_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25f84b28-695b-4d32-b96c-914226444b9f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1166a1ab-a5b1-456c-8bd7-a71a202292ff"}}}}, {"uuid": "9b8f6789-1de8-413d-a3c4-5410bef958a2", "name": "88d15826-274e-4901-8860-5e4d7a9c38d6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7943609059660943, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8824322096654456, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2eeb66ef-6a15-4ad6-add3-1a48e608df1b", "name": "c859bfb6-b1e9-467f-a6ba-c0a872cd4dac", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9b8f6789-1de8-413d-a3c4-5410bef958a2"}}}]}, {"uuid": "2afb5f2d-a7d6-4d0d-814f-9ed02e37d632", "name": "load_p1rlv857_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a28cc17a-125d-4b7b-a697-230e3f8853b5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2eeb66ef-6a15-4ad6-add3-1a48e608df1b"}}}}, {"uuid": "9aa8e408-47da-4da3-b3eb-a373bf49b2b0", "name": "b4a34dc0-77f6-48fd-974b-3e39b8b29a49_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7943609059660943, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8824322096654456, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "234024af-de66-4b33-8129-d6b8059bdd80", "name": "75c1079f-de07-4098-bd81-29f4198fc437", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9aa8e408-47da-4da3-b3eb-a373bf49b2b0"}}}]}, {"uuid": "094df460-37a3-4b56-a3b9-f5b2b6be0ba3", "name": "load_p1rlv857_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a28cc17a-125d-4b7b-a697-230e3f8853b5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "234024af-de66-4b33-8129-d6b8059bdd80"}}}}, {"uuid": "7323b44d-a2c5-4f50-b500-5800eb2f378e", "name": "a23685aa-5fd7-4cf5-a7a7-40e6e2203420_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.360087651208046, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7361845082285076, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a1c70345-7ac7-4ce2-a973-c7c9094de834", "name": "9a73ab21-8bd4-42fc-8948-6e32c8dee34d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7323b44d-a2c5-4f50-b500-5800eb2f378e"}}}]}, {"uuid": "2d3bce52-a0d9-407c-9a3d-47bad3f824a1", "name": "load_p1rlv858_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab33ce2f-3131-4cfb-8df2-329fb4aa76b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a1c70345-7ac7-4ce2-a973-c7c9094de834"}}}}, {"uuid": "a75b42ea-cf4f-482a-818d-e620e774eaba", "name": "6cd91bc1-b5b9-4e8d-9a2a-e6ae360b7edb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.360087651208046, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7361845082285076, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a51406a8-a8d8-4294-a054-2829c350a2c5", "name": "0b07e4b1-3489-4d32-9b21-cdb8c09841d9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a75b42ea-cf4f-482a-818d-e620e774eaba"}}}]}, {"uuid": "bd4c08fd-1f86-4ca0-861b-d97428390c2a", "name": "load_p1rlv858_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab33ce2f-3131-4cfb-8df2-329fb4aa76b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a51406a8-a8d8-4294-a054-2829c350a2c5"}}}}, {"uuid": "35086a57-9857-4866-a09e-231dd9f6fca0", "name": "e8a02a80-3e02-43f8-86aa-0139292ee6c8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.292799122473319, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5385753507809203, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "092c0dd2-64c4-4fdb-b042-0fba4bd9bd72", "name": "b309218d-ff40-4e21-b696-16d8cb4504e8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "35086a57-9857-4866-a09e-231dd9f6fca0"}}}]}, {"uuid": "ea82bf4d-44fc-471f-bb20-faa13e025ddc", "name": "load_p1rlv859_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ea0f4f5-2024-45a8-9f8f-f5963e7d2727"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "092c0dd2-64c4-4fdb-b042-0fba4bd9bd72"}}}}, {"uuid": "15eca634-df48-414d-a350-28d6a67c60ac", "name": "10d83fbf-95e7-4c47-84ea-795b3e674406_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.292799122473319, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5385753507809203, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4f3dd59b-9b2a-4fa7-b2f0-77b46d74ea85", "name": "5909bc2c-6ea9-400d-a1ac-7ec4cf3b3195", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "15eca634-df48-414d-a350-28d6a67c60ac"}}}]}, {"uuid": "1d319791-32ab-4a13-9b3a-4c28dfee0e16", "name": "load_p1rlv859_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ea0f4f5-2024-45a8-9f8f-f5963e7d2727"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4f3dd59b-9b2a-4fa7-b2f0-77b46d74ea85"}}}}, {"uuid": "3946463d-5ba0-4265-99c7-f95fda7d6324", "name": "c226f9fe-97d4-4f13-a604-ed5ef5335011_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5424601784243566, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31457775613808403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9b716c1f-225f-4a38-b498-7f218bc827ff", "name": "ec4ad5d1-316c-48cc-adf4-d43151ae92d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3946463d-5ba0-4265-99c7-f95fda7d6324"}}}]}, {"uuid": "5ea998e1-259b-4b48-86ae-f263a6e51b5c", "name": "load_p1rlv860_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bada1117-5605-4aec-9314-8013ed243e3c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9b716c1f-225f-4a38-b498-7f218bc827ff"}}}}, {"uuid": "39e0e2ea-3427-41a3-a24c-f874143fd4cf", "name": "c975a955-75c7-4e7c-b1bf-c42d83f0ee8d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5424601784243566, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31457775613808403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ab3bcd05-6f6f-4d10-8807-13db4da37a09", "name": "90e3bd87-98c5-4cff-b849-90a6c5e49d55", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "39e0e2ea-3427-41a3-a24c-f874143fd4cf"}}}]}, {"uuid": "087c8d07-6c8a-4ea0-8c2e-36d042741e85", "name": "load_p1rlv860_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bada1117-5605-4aec-9314-8013ed243e3c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ab3bcd05-6f6f-4d10-8807-13db4da37a09"}}}}, {"uuid": "b615cda8-1baf-4369-99b6-e1aa112b1d04", "name": "b0859b4f-82e2-43c9-a5e7-4d90cbf261fc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2766983969851713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5028612878254624, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2b07c294-9599-4629-ab6a-de6a01d14c82", "name": "e7546a56-0a12-4d9c-8664-ed7e6eb841c1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b615cda8-1baf-4369-99b6-e1aa112b1d04"}}}]}, {"uuid": "96800c02-0db3-4db9-b8b6-28b7fc263295", "name": "load_p1rlv861_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a07d30f-6909-4d74-be8a-1ff8343b4419"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2b07c294-9599-4629-ab6a-de6a01d14c82"}}}}, {"uuid": "4659d82a-2d77-4710-82ac-960b753b0425", "name": "3bbc9222-9155-4c7a-9d39-cb8512724ca8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2766983969851713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5028612878254624, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "72a5a44c-ba79-466f-abea-f385d63ff89d", "name": "e23362be-3012-4f38-9444-437cf2f9fb67", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4659d82a-2d77-4710-82ac-960b753b0425"}}}]}, {"uuid": "1cf2e81e-bfb4-48c2-9ef3-c4244e1d4176", "name": "load_p1rlv861_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a07d30f-6909-4d74-be8a-1ff8343b4419"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "72a5a44c-ba79-466f-abea-f385d63ff89d"}}}}, {"uuid": "36119b84-0eeb-4a54-a521-ea143e122c70", "name": "f8af5d24-b499-47a4-bf61-a9a39a38a305_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.037961707989467, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3691190849967326, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aaa7a400-9669-453e-987b-e49830388166", "name": "b597c1da-1f78-4424-92de-98ee97ef58bd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "36119b84-0eeb-4a54-a521-ea143e122c70"}}}]}, {"uuid": "49da019f-d34e-4676-a7c3-83d7fdd9f1d1", "name": "load_p1rlv862_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5e2c3a2-32c0-4bb9-9802-265cec784974"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aaa7a400-9669-453e-987b-e49830388166"}}}}, {"uuid": "5006d372-3b1d-408c-abe2-6f3208eac730", "name": "ba8b441d-bec1-43f1-8574-b8a92ff222ba_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.037961707989467, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3691190849967326, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f31efed1-ba00-4062-ab30-6e483d25fc84", "name": "210c84bb-bc4c-4f53-ad8c-625114ae5c83", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5006d372-3b1d-408c-abe2-6f3208eac730"}}}]}, {"uuid": "fd3a664f-196a-43fa-bfdc-53efd02af17c", "name": "load_p1rlv862_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5e2c3a2-32c0-4bb9-9802-265cec784974"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f31efed1-ba00-4062-ab30-6e483d25fc84"}}}}, {"uuid": "ace38ad0-adb5-413b-b79d-668ae95cb220", "name": "ceae3b7d-532d-4b92-a59b-64dee73af957_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1350143243427975, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1351898450115188, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d7fbc366-1f07-41d0-bec5-af65c6df29d4", "name": "15d9ac3c-7a40-46a9-9835-115380acddf0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ace38ad0-adb5-413b-b79d-668ae95cb220"}}}]}, {"uuid": "5966ebaa-cfd3-4095-ade4-1f653ab63ea7", "name": "load_p1rlv863_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09a7be46-a1bf-459d-836b-beb64324809b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d7fbc366-1f07-41d0-bec5-af65c6df29d4"}}}}, {"uuid": "1d53c84b-81f1-420c-8482-438a751eed35", "name": "3da80d10-b10f-4974-a8f9-5dd2816e5bd9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1350143243427975, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1351898450115188, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "37c8776e-dbfe-404b-b52e-a7685eca1be1", "name": "e545727b-1cfe-4117-be2f-530ecedfdadf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1d53c84b-81f1-420c-8482-438a751eed35"}}}]}, {"uuid": "7033a7f2-be4e-454a-a54a-997dfcea2f79", "name": "load_p1rlv863_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09a7be46-a1bf-459d-836b-beb64324809b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "37c8776e-dbfe-404b-b52e-a7685eca1be1"}}}}, {"uuid": "679bc03a-95ec-4dac-b478-740fb11b7f8b", "name": "026f57e0-a554-4cd6-aff1-1162bc769970_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0404861968223509, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5307917165881004, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0b92cee6-e830-479d-98b9-5b58f61604e9", "name": "d677f903-718f-4ebe-acc8-9aa5591d70a4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "679bc03a-95ec-4dac-b478-740fb11b7f8b"}}}]}, {"uuid": "7fb1a340-9cdd-4d27-87c6-975d10aab344", "name": "load_p1rlv864_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e2a8871-7bc4-497f-9954-38db92cb3eba"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0b92cee6-e830-479d-98b9-5b58f61604e9"}}}}, {"uuid": "51792ec8-29d7-4f26-8ccf-07b1c59ea1fe", "name": "441a7382-13b0-4a4b-a9cb-a6efc1080bce_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0404861968223509, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5307917165881004, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50e57df0-1fc7-4e3b-a217-56d086a3f85d", "name": "f845ac47-866f-4ed9-bd8d-b7b2968e8703", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "51792ec8-29d7-4f26-8ccf-07b1c59ea1fe"}}}]}, {"uuid": "5f436709-285d-4efc-b7a5-b90e8d251195", "name": "load_p1rlv864_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e2a8871-7bc4-497f-9954-38db92cb3eba"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50e57df0-1fc7-4e3b-a217-56d086a3f85d"}}}}, {"uuid": "38cc0407-c5ca-4e8b-89f6-76d0f546dc24", "name": "222da507-c072-4b19-a029-97d7de16ca33_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.396349422902612, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13402564403017767, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a83ec3a0-5d64-4bfe-ae1a-d5fb9a412442", "name": "d6ed423b-17ab-463e-9c6f-6c4ea05e864c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "38cc0407-c5ca-4e8b-89f6-76d0f546dc24"}}}]}, {"uuid": "c2714419-2921-4ab1-b9c6-5aa354bac9c6", "name": "load_p1rlv865_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abdfa5db-c398-4638-805d-6d55597e1921"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a83ec3a0-5d64-4bfe-ae1a-d5fb9a412442"}}}}, {"uuid": "8144f7d5-cfad-47c7-bc29-c99638c052ee", "name": "5a0fbef2-a383-4d19-b9b5-a19466da2dcf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.396349422902612, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13402564403017767, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6527d9ad-e156-4133-acb9-f3e5763eec6c", "name": "d1944846-4e8d-4ef5-8a4c-1555100cb335", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8144f7d5-cfad-47c7-bc29-c99638c052ee"}}}]}, {"uuid": "13136e7a-d669-4975-b669-a1c432915c92", "name": "load_p1rlv865_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abdfa5db-c398-4638-805d-6d55597e1921"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6527d9ad-e156-4133-acb9-f3e5763eec6c"}}}}, {"uuid": "42bfd63a-37b3-4f04-8158-3ef4471651bf", "name": "3f3992b8-a126-4bb3-b05c-89840855c1f0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3885774782241163, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12624891415512582, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "560745e8-0452-43ef-81d7-630181294706", "name": "cce335ea-f452-48ad-8707-9c2d3280e24c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "42bfd63a-37b3-4f04-8158-3ef4471651bf"}}}]}, {"uuid": "b2b6fa33-8085-4b64-82cd-4fe96219ea44", "name": "load_p1rlv866_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b4834dc-6bdf-4102-bc13-589392b2e75a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "560745e8-0452-43ef-81d7-630181294706"}}}}, {"uuid": "968e05c7-a79f-4514-a3de-87e33419cff2", "name": "85ae0cf9-82bc-4d01-b049-fcd4b6fb9ac1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3885774782241163, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12624891415512582, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d1de2c42-fc5f-4cb4-92ec-5e9beac9c261", "name": "c12a43c2-a29e-4bcd-bdeb-7a0306225d8c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "968e05c7-a79f-4514-a3de-87e33419cff2"}}}]}, {"uuid": "faa57801-b454-43b6-bdda-eeaafa76b9e8", "name": "load_p1rlv866_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b4834dc-6bdf-4102-bc13-589392b2e75a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d1de2c42-fc5f-4cb4-92ec-5e9beac9c261"}}}}, {"uuid": "1c879820-7c35-46b9-8168-00f7e509aef4", "name": "403f8627-c8d6-40e8-bfcb-47c03dcf74d8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6434260893942235, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2588956175598443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "171928bd-80b9-42bb-a91e-b9ab7ae8989a", "name": "f8b5b9e7-4f04-4cdd-bb13-380da2aeb0ea", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1c879820-7c35-46b9-8168-00f7e509aef4"}}}]}, {"uuid": "c6967476-77ef-442f-bfdb-222f6502e733", "name": "load_p1rlv867_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a7cca48-fd4b-4630-a479-55f2b6ada03b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "171928bd-80b9-42bb-a91e-b9ab7ae8989a"}}}}, {"uuid": "114181e2-86b0-4925-9cc9-0d7ca64c7407", "name": "1c2a3eea-1172-431e-87b2-17ad9df21235_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6434260893942235, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2588956175598443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "28a7f3f9-cd2e-428a-a9bd-d33a2e4fed11", "name": "0de580cd-f883-4a16-8008-61a93c33a7da", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "114181e2-86b0-4925-9cc9-0d7ca64c7407"}}}]}, {"uuid": "385a2115-4295-4941-a7fb-a59564b4f508", "name": "load_p1rlv867_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a7cca48-fd4b-4630-a479-55f2b6ada03b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "28a7f3f9-cd2e-428a-a9bd-d33a2e4fed11"}}}}, {"uuid": "b9f7f963-fb43-4e1e-871d-38f0d87206ca", "name": "a1d0da70-7bc9-493c-94ef-abe966f8bcdb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b25e2402-e84a-4a40-80a0-ce8be1a5322b", "name": "2e2a91d1-2bc1-4316-a111-5371893ddf75", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b9f7f963-fb43-4e1e-871d-38f0d87206ca"}}}]}, {"uuid": "2e469aa9-dbf8-4b95-8f28-e8a2fb8c1ea1", "name": "load_p1rlv868_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "009758e3-b4ae-427a-9c30-f2a8bb2953d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b25e2402-e84a-4a40-80a0-ce8be1a5322b"}}}}, {"uuid": "8328adfe-9dc1-4885-b0eb-17be3134c569", "name": "18746686-2a2d-4f4e-bad6-fd16dbe2a33f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "467c6f11-7830-4b68-b6d9-a210abde83f1", "name": "18413f31-a538-4d0d-bd03-11a127f553d3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8328adfe-9dc1-4885-b0eb-17be3134c569"}}}]}, {"uuid": "547a971b-dbf5-4c1f-91ab-7385e3c89f7a", "name": "load_p1rlv868_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "009758e3-b4ae-427a-9c30-f2a8bb2953d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "467c6f11-7830-4b68-b6d9-a210abde83f1"}}}}, {"uuid": "eb92c93e-422c-40d0-b704-4fc3df412ad6", "name": "ffe3ad19-366b-4fd2-9f71-a5b150b6eb7c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.338024948143216, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9096814401074484, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d3416bc5-2dff-48ff-a630-f670458c570d", "name": "d0e0e291-1ed0-4993-8ee3-a05937ce6327", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eb92c93e-422c-40d0-b704-4fc3df412ad6"}}}]}, {"uuid": "4d86c288-ca8d-41fb-8c4d-b10435f7da15", "name": "load_p1rlv869_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fb4003d-498a-494d-89ca-f222d921f63a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d3416bc5-2dff-48ff-a630-f670458c570d"}}}}, {"uuid": "3201dcf9-4b41-468e-a205-000c11004b4e", "name": "6dcbacc4-865b-4a74-be53-090263776564_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.338024948143216, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9096814401074484, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b7edcd35-a7b1-48bc-af27-1b3853eb3475", "name": "6f04df3d-66d0-447a-92b9-abd6bf18984b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3201dcf9-4b41-468e-a205-000c11004b4e"}}}]}, {"uuid": "61512b03-7ff1-4d52-8b9f-426e1d071061", "name": "load_p1rlv869_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fb4003d-498a-494d-89ca-f222d921f63a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b7edcd35-a7b1-48bc-af27-1b3853eb3475"}}}}, {"uuid": "c5372011-7783-401d-9a42-ba2d894a238e", "name": "f1f19423-67b8-402b-8984-0f898b9811cf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4212042062341066, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7562106926743815, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7dbdc0a2-3f64-4373-859d-3a26df047799", "name": "eb64a4e4-6070-40ec-bc13-6a2922d7cd73", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c5372011-7783-401d-9a42-ba2d894a238e"}}}]}, {"uuid": "4d51d8cd-d0e6-4b8e-a4ad-5247983a09be", "name": "load_p1rlv7783_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd7a84bb-8aa4-4668-9791-a363741823e9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7dbdc0a2-3f64-4373-859d-3a26df047799"}}}}, {"uuid": "356fabb2-65b3-430b-a312-5aa18a3c401c", "name": "13d0f027-f3af-4bb2-82ae-f9bbfede334a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4212042062341066, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7562106926743815, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7341ff5f-3431-4fc3-8e0b-f52c7bc7373a", "name": "d5d33575-ebee-4695-b382-0da403d99f1f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "356fabb2-65b3-430b-a312-5aa18a3c401c"}}}]}, {"uuid": "e04e1abb-c60f-41f0-a774-c47db62edcb7", "name": "load_p1rlv7783_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd7a84bb-8aa4-4668-9791-a363741823e9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7341ff5f-3431-4fc3-8e0b-f52c7bc7373a"}}}}, {"uuid": "1713edaf-ac0f-44a1-98ba-b0cce436bc52", "name": "17302292-37b7-4d04-a4ad-5f84bccad702_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7101501378288513, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4527501720520811, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0199c07e-7ae5-4eae-8840-bc887b10f47c", "name": "21e0d40f-8044-479d-8281-30ccfe9937af", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1713edaf-ac0f-44a1-98ba-b0cce436bc52"}}}]}, {"uuid": "96a58958-439a-468e-b3d9-56cbf024da8c", "name": "load_p1rlv7784_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24e665a0-3ba6-46a7-bc02-327b6f77c409"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0199c07e-7ae5-4eae-8840-bc887b10f47c"}}}}, {"uuid": "dcdf6c24-e443-4d30-b513-55002574edab", "name": "b5c7351b-44db-4dad-a029-13aaf73a1b56_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7101501378288513, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4527501720520811, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "96ae4a60-29b4-4c2a-994d-969e5605b8e5", "name": "ba592037-68f9-4d58-8f80-54b47f0019dc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dcdf6c24-e443-4d30-b513-55002574edab"}}}]}, {"uuid": "0dd29067-5363-4676-abfc-354c6ff02846", "name": "load_p1rlv7784_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24e665a0-3ba6-46a7-bc02-327b6f77c409"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "96ae4a60-29b4-4c2a-994d-969e5605b8e5"}}}}, {"uuid": "1f4bd4b8-5e77-4a63-b4ce-b7fb5e07d7d7", "name": "00369e15-8a8a-4925-b8e2-ab8a0b504b7f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7392455382108751, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4362253237121403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "810e40dc-14f6-45be-b35f-0f870f133692", "name": "5b77ab36-8077-415f-aa20-26ad0a9095f3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1f4bd4b8-5e77-4a63-b4ce-b7fb5e07d7d7"}}}]}, {"uuid": "b29d32c3-c841-4de0-a9bb-6c3bd598ecf0", "name": "load_p1rlv7785_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1571d1a3-a151-4972-8cb1-aeb36b660abc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "810e40dc-14f6-45be-b35f-0f870f133692"}}}}, {"uuid": "fe5e92cf-14d5-40c8-80c9-994efda6330b", "name": "2c63d8f0-6314-4200-907f-007d8fdc7b8a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7392455382108751, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4362253237121403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8eb3fe60-7f0f-4d31-96ea-b471cece8da8", "name": "010de59b-39bf-4135-9331-e5121db1ff1d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fe5e92cf-14d5-40c8-80c9-994efda6330b"}}}]}, {"uuid": "491c2e8e-4768-402a-9265-b6aed108f402", "name": "load_p1rlv7785_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1571d1a3-a151-4972-8cb1-aeb36b660abc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8eb3fe60-7f0f-4d31-96ea-b471cece8da8"}}}}, {"uuid": "c4d52b83-c123-4dad-a510-e4e0acb90ef8", "name": "86cc9856-6517-480c-bd1f-5cb3042f8f64_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4818511326065424, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6748395523926414, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e73684a1-b61e-4422-a2d1-b6d0db4ad5cb", "name": "e55cf8bd-e951-4401-887c-da8167795169", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c4d52b83-c123-4dad-a510-e4e0acb90ef8"}}}]}, {"uuid": "199b5478-37e0-4ed6-8017-12a45432003a", "name": "load_p1rlv7786_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af62e3c-9357-4505-a2f6-3b4252dab81b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e73684a1-b61e-4422-a2d1-b6d0db4ad5cb"}}}}, {"uuid": "34a004b2-eea5-415a-8e47-262212d2a7d5", "name": "d016a180-f514-4118-b5ab-0bee72e27724_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4818511326065424, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6748395523926414, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "105167fd-90f0-40a8-a0b1-c598a4aff4a7", "name": "26f2e62d-d3bb-478c-b5ad-f367a0eca836", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "34a004b2-eea5-415a-8e47-262212d2a7d5"}}}]}, {"uuid": "3dd5337e-db69-4d76-b98f-47d0ed2a0fa6", "name": "load_p1rlv7786_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af62e3c-9357-4505-a2f6-3b4252dab81b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "105167fd-90f0-40a8-a0b1-c598a4aff4a7"}}}}, {"uuid": "98e8bc3a-ae30-47a4-b7d1-281b95a25c74", "name": "457cbb44-1f6e-4e4a-a8d2-a1c3fd8ad123_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9705664843982345, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20295664886439999, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10ff4285-30ed-41a3-8f7e-9ebc82a27b21", "name": "5374c77e-7f21-431e-a7b2-e576db6ca92a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "98e8bc3a-ae30-47a4-b7d1-281b95a25c74"}}}]}, {"uuid": "5377086a-e04a-491c-8e54-efd38306a144", "name": "load_p1rlv10453_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09926231-b077-4aa6-afd8-acf89744865a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10ff4285-30ed-41a3-8f7e-9ebc82a27b21"}}}}, {"uuid": "8a0a012e-28ce-42d7-a4bd-9ee349d700bc", "name": "25f0cc32-c195-40fb-83d4-0d08a5fdd278_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9705664843982345, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20295664886439999, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fbc1bd32-f7d7-4287-adfb-b99cc1a70bc5", "name": "d67682f3-c1e0-4618-abe0-2b29d2af39ff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a0a012e-28ce-42d7-a4bd-9ee349d700bc"}}}]}, {"uuid": "bd7d0a1e-d67b-4a4e-a2c0-a7a1b73037af", "name": "load_p1rlv10453_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09926231-b077-4aa6-afd8-acf89744865a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fbc1bd32-f7d7-4287-adfb-b99cc1a70bc5"}}}}, {"uuid": "10730986-0710-4e81-990f-23beb309d894", "name": "c2d3e7d3-19b1-44f4-b6fa-b8cd5157c579_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9288135994675786, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3237835349774649, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4db3bb81-f55f-4f61-a851-1a862c76b727", "name": "58e3f632-f96c-40e1-a83e-23ef309dba25", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "10730986-0710-4e81-990f-23beb309d894"}}}]}, {"uuid": "3a7f5ff3-b2dd-454a-99fc-5b591d560ba5", "name": "load_p1rlv10468_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a639e8d-ac8c-46e8-a4b5-6c551612b209"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4db3bb81-f55f-4f61-a851-1a862c76b727"}}}}, {"uuid": "c7776e75-cfc5-4157-8f3a-7503c9711283", "name": "20e4f9b1-b0fa-458b-b0ce-e9170c32f91d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9288135994675786, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3237835349774649, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a6dc196c-5ae1-4ab2-805f-2810cbff7632", "name": "5083f26e-7835-4fd1-93f4-b27ec12194b4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c7776e75-cfc5-4157-8f3a-7503c9711283"}}}]}, {"uuid": "339c7105-f33b-45e5-abcf-ef13c4974cbf", "name": "load_p1rlv10468_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a639e8d-ac8c-46e8-a4b5-6c551612b209"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a6dc196c-5ae1-4ab2-805f-2810cbff7632"}}}}, {"uuid": "c1025d61-e42a-41dd-8a3c-2bb129424d05", "name": "a10cf00c-67ac-4213-ad57-a683b93ef409_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.137360281336931, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.443734948632237, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c8407680-4514-4a23-a4e1-14107c4aa215", "name": "00e230a2-ffb8-423f-88ad-611c74946da7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c1025d61-e42a-41dd-8a3c-2bb129424d05"}}}]}, {"uuid": "d5c520ff-f7a9-48be-870b-1d2208006878", "name": "load_p1rlv10482_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d40fc87f-1b73-4ed4-a397-dbc94312dcad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c8407680-4514-4a23-a4e1-14107c4aa215"}}}}, {"uuid": "6634dc96-29a7-43b5-81a6-334cba43847c", "name": "e237970c-6462-4344-af07-c9d1ad1343a4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.137360281336931, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.443734948632237, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e887fdb7-614b-4d04-b57a-0d1cc3fd571e", "name": "00e2e47e-f8b0-489e-947f-2a9f364dce18", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6634dc96-29a7-43b5-81a6-334cba43847c"}}}]}, {"uuid": "997faa1f-d5f7-441a-869d-4e69da540525", "name": "load_p1rlv10482_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d40fc87f-1b73-4ed4-a397-dbc94312dcad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e887fdb7-614b-4d04-b57a-0d1cc3fd571e"}}}}, {"uuid": "fe4be1fd-0512-4eb7-9f7f-11886ff23ff1", "name": "64750c64-f3ba-45b1-816b-750e7b1e9b4d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.982015016710447, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5720113989287618, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "078f82f7-4f75-410d-a499-337abb2ebaac", "name": "3e87d6fc-2a31-40a4-9ce4-830ded723b7a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fe4be1fd-0512-4eb7-9f7f-11886ff23ff1"}}}]}, {"uuid": "cca90958-3097-4288-b429-b28e1fd1caf7", "name": "load_p1rlv10517_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "efd01236-6ba3-424e-829b-3f3950ce6265"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "078f82f7-4f75-410d-a499-337abb2ebaac"}}}}, {"uuid": "a170ae41-2689-494f-aa57-d9df60f90d08", "name": "c9c3960e-61bf-4a9b-bba7-44c9143e27e6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.982015016710447, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5720113989287618, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "269b3854-5224-400f-839d-f2b589390694", "name": "d192040d-7e21-4a69-b5fb-8ea8137bca90", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a170ae41-2689-494f-aa57-d9df60f90d08"}}}]}, {"uuid": "36344287-a32a-46aa-a960-835474341ea3", "name": "load_p1rlv10517_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "efd01236-6ba3-424e-829b-3f3950ce6265"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "269b3854-5224-400f-839d-f2b589390694"}}}}, {"uuid": "adcf0a93-9a94-431d-9ebc-6835e5a8059a", "name": "2036e332-5afc-465e-9d87-d99c6f411b95_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.160991762543576, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9056130261441641, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2c486189-5467-480d-a6ad-ae7c6290458c", "name": "eaabd49c-a213-4fd5-9cca-291701c002fa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "adcf0a93-9a94-431d-9ebc-6835e5a8059a"}}}]}, {"uuid": "65822cb1-153e-4fbc-8610-1b9fc2dc485c", "name": "load_p1rlv11503_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "773a6b9e-d708-4f7c-a901-9406bcc3dcde"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2c486189-5467-480d-a6ad-ae7c6290458c"}}}}, {"uuid": "6799b0b2-e42f-4ddc-bc71-b87a75fc8f59", "name": "edc9e2eb-7c62-47ab-ba2c-c1119079824a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.160991762543576, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9056130261441641, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c30fe11c-27f9-4a6f-8a66-50f3396162a4", "name": "834f3ff6-6233-4dd4-a5a0-dafe3f984f1b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6799b0b2-e42f-4ddc-bc71-b87a75fc8f59"}}}]}, {"uuid": "6949907d-ea62-46ba-b015-cc5a3054b94b", "name": "load_p1rlv11503_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "773a6b9e-d708-4f7c-a901-9406bcc3dcde"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c30fe11c-27f9-4a6f-8a66-50f3396162a4"}}}}, {"uuid": "320bb1ad-fb4a-4e8a-991d-a2cef4662f2b", "name": "45904608-adc0-44ee-b20b-377a44260f1c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 15.606876661659024, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.2167580478298823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a224ecb-4f16-4ea5-8f6f-384ece3a523c", "name": "45904608-adc0-44ee-b20b-377a44260f1c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 15.606876661659024, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.2167580478298823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "68e57e33-9943-44b8-b264-b5560c1d4b4c", "name": "45904608-adc0-44ee-b20b-377a44260f1c_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 15.606876661659024, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.2167580478298823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4748482d-bd45-4d2c-870e-3fb5e1a21449", "name": "a4709721-35d1-451c-abcd-4ef6fdbb9e7c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "320bb1ad-fb4a-4e8a-991d-a2cef4662f2b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0a224ecb-4f16-4ea5-8f6f-384ece3a523c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "68e57e33-9943-44b8-b264-b5560c1d4b4c"}}}]}, {"uuid": "1c4e8311-a62b-4a80-b43d-dc5ded5311c3", "name": "load_p1rlv11506", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "82988650-787d-41de-bca7-4f3c08ccad15"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4748482d-bd45-4d2c-870e-3fb5e1a21449"}}}}, {"uuid": "95c9105d-b00f-4e2d-932b-b74067800d34", "name": "cefbed57-dfef-4d79-b045-a385ca1060a0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 10.178690882168185, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.8011442962112136, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4addb2d3-a678-4527-be47-baab300fcbc5", "name": "1bf14111-5b0a-48df-9573-c9b4a0915629", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "95c9105d-b00f-4e2d-932b-b74067800d34"}}}]}, {"uuid": "be46345e-157c-4ee5-8acb-761ea129e52c", "name": "load_p1rlv11513_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84b9d44e-2c8d-4cee-a9d2-327a41ab8dad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4addb2d3-a678-4527-be47-baab300fcbc5"}}}}, {"uuid": "a8ab0468-5638-4f7a-8350-694c2857b3b2", "name": "abaaafc3-3725-42e3-a946-bd918dcaad8f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 10.178690882168185, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.8011442962112136, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ec915dd7-5306-43d9-aa73-5e9131b64835", "name": "c54f0076-4198-48b3-b38d-657bf46d4e2e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a8ab0468-5638-4f7a-8350-694c2857b3b2"}}}]}, {"uuid": "622a3b87-1a77-42d7-ba31-d9a7b2703765", "name": "load_p1rlv11513_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84b9d44e-2c8d-4cee-a9d2-327a41ab8dad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ec915dd7-5306-43d9-aa73-5e9131b64835"}}}}, {"uuid": "c66757e7-156b-47a2-bf3c-60b350e5671b", "name": "227d777e-40c2-48b4-90bb-65961da9a105_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2659851154673674, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7880475847724098, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0b50e2b1-205e-433c-9316-e198d133f206", "name": "54b20506-3d9b-4132-851d-4475eebc75b2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c66757e7-156b-47a2-bf3c-60b350e5671b"}}}]}, {"uuid": "a94a1d11-35e4-461d-ba20-7085e88df6a2", "name": "load_p1rlv11516_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86d82a1e-1596-4fb3-9f3d-44c9553396d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0b50e2b1-205e-433c-9316-e198d133f206"}}}}, {"uuid": "9cb4e692-7ff1-4d87-82a1-033a7139968e", "name": "791e23e8-102a-43c4-baa3-d5c8ae44f2d8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2659851154673674, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7880475847724098, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d679bb72-207d-4856-892d-58dd46d23339", "name": "c7194d59-734a-4c7d-839b-5429638241f6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9cb4e692-7ff1-4d87-82a1-033a7139968e"}}}]}, {"uuid": "050ba298-c20a-4ec0-beb3-b94e3808c5ec", "name": "load_p1rlv11516_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86d82a1e-1596-4fb3-9f3d-44c9553396d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d679bb72-207d-4856-892d-58dd46d23339"}}}}, {"uuid": "e89a76ae-f8b2-42fb-a46a-b59b5774aa94", "name": "10fb628e-fe01-4f5b-b631-dd5fda3853b9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.902887215219663, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.111231385342157, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10ea2792-e7fa-4609-8180-c5ffb4d298ea", "name": "e8c790b6-8571-498c-b018-36135359b8db", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e89a76ae-f8b2-42fb-a46a-b59b5774aa94"}}}]}, {"uuid": "8299b35d-b954-47de-8828-e54a4b3d5896", "name": "load_p1rlv11517_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "179d1d84-0dfe-4920-a039-009f33bc1d8d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10ea2792-e7fa-4609-8180-c5ffb4d298ea"}}}}, {"uuid": "9653af9d-2182-458d-b7b2-1dc199a9116d", "name": "6017e7e0-c29c-4d8b-8bde-e5e9ca1f6340_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.902887215219663, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.111231385342157, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a479e565-1151-4019-80aa-a642f090d9be", "name": "0ab2c7d4-ca0c-4bcc-af61-7866d7984102", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9653af9d-2182-458d-b7b2-1dc199a9116d"}}}]}, {"uuid": "b740edad-3e1a-4df3-afce-70e52538d492", "name": "load_p1rlv11517_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "179d1d84-0dfe-4920-a039-009f33bc1d8d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a479e565-1151-4019-80aa-a642f090d9be"}}}}, {"uuid": "bccabf64-2cc5-4387-9063-037efea74407", "name": "1861f9e2-4187-4864-b570-207cc6126bb6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.815209062299411, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.284220525554307, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7f72e181-164e-4eca-9e0b-189f57e4a521", "name": "1861f9e2-4187-4864-b570-207cc6126bb6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.815209062299411, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.284220525554307, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d62011ec-36d9-4fd0-b81f-4d5f7e76902d", "name": "1861f9e2-4187-4864-b570-207cc6126bb6_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.815209062299411, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.284220525554307, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "615c3356-445c-4f98-b970-8b8bcf87321c", "name": "e30959d0-13f7-44fe-86ec-b383372d22e1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bccabf64-2cc5-4387-9063-037efea74407"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7f72e181-164e-4eca-9e0b-189f57e4a521"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d62011ec-36d9-4fd0-b81f-4d5f7e76902d"}}}]}, {"uuid": "2948aa17-5f03-4d92-9ea6-60b285cfde09", "name": "load_p1rlv11520", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22054033-4e69-41b0-b321-a4d086d20574"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "615c3356-445c-4f98-b970-8b8bcf87321c"}}}}, {"uuid": "376e485b-5ffb-4d5a-ab9c-64c132605a26", "name": "0650d81b-3963-4552-9f0d-b6acae375567_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.368937976023913, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.122061037955929, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e7fbaefc-92c8-4fa6-a238-3e6675385749", "name": "6d7f0b7e-8a13-40aa-91d7-3116020e24e4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "376e485b-5ffb-4d5a-ab9c-64c132605a26"}}}]}, {"uuid": "24ac8477-c762-4578-83f9-36c4764ce044", "name": "load_p1rlv11521_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8f0f8a2-f528-45bd-8fbd-22f6699fe7e0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e7fbaefc-92c8-4fa6-a238-3e6675385749"}}}}, {"uuid": "caae9a53-cd7f-4831-9508-c2fee2b76934", "name": "0a722b1d-473f-4b6c-95f4-4fbd79aa4363_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.368937976023913, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.122061037955929, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f0b2e0be-2a69-47bc-afc9-0bb2f64630a5", "name": "b13519da-e21b-4c44-92a3-01a34458956d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "caae9a53-cd7f-4831-9508-c2fee2b76934"}}}]}, {"uuid": "80fb38d5-a103-45ea-86fb-d8189b370241", "name": "load_p1rlv11521_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8f0f8a2-f528-45bd-8fbd-22f6699fe7e0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f0b2e0be-2a69-47bc-afc9-0bb2f64630a5"}}}}, {"uuid": "4fed72ed-a1e0-4262-aaaf-9c856ccf37b2", "name": "52385853-2633-446a-b93e-aa1b1774eb15_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.71666338297624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.8739990837811158, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0aae9508-102f-4e20-96f8-94b35ed671f6", "name": "52385853-2633-446a-b93e-aa1b1774eb15_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.71666338297624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.8739990837811158, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cc9d9e94-7981-4ee8-bcbf-f5701ba564c1", "name": "52385853-2633-446a-b93e-aa1b1774eb15_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.71666338297624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.8739990837811158, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2a91d892-91c6-46ae-8e47-a9f3b59fc4eb", "name": "41d8b914-1843-44e5-9884-4acfb3532ffa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4fed72ed-a1e0-4262-aaaf-9c856ccf37b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0aae9508-102f-4e20-96f8-94b35ed671f6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cc9d9e94-7981-4ee8-bcbf-f5701ba564c1"}}}]}, {"uuid": "c6a2d41d-89f4-40a1-ae53-15df7b87dd3d", "name": "load_p1rlv11522", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "176b348f-9ecf-4a82-bdf9-f2e5d5a07af7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2a91d892-91c6-46ae-8e47-a9f3b59fc4eb"}}}}, {"uuid": "2e1897ab-fffe-4051-9e23-ec687c8aef6d", "name": "c465d6c6-c4fd-4311-bd32-332bd93cf1cb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 20.596071016561904, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.1080231298812775, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2c067e42-b521-4917-b01a-4328455c627c", "name": "e109b65b-daae-4732-99bc-a5349c5862f2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2e1897ab-fffe-4051-9e23-ec687c8aef6d"}}}]}, {"uuid": "f928863f-0387-490e-b720-40d3ac320fcc", "name": "load_p1rlv11523_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69eba934-3f80-4abc-b5e8-9cdc79aa05a3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2c067e42-b521-4917-b01a-4328455c627c"}}}}, {"uuid": "e0a9ad2d-dbd1-4237-b3e2-5ec5a2c10f3a", "name": "9bcd81db-6dfb-40ba-bf8d-fd41202caeaf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 20.596071016561904, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.1080231298812775, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4899fddb-d844-4080-b45a-7bccd4a40de6", "name": "994ac187-1add-4de4-94e1-448e7bd00ee9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e0a9ad2d-dbd1-4237-b3e2-5ec5a2c10f3a"}}}]}, {"uuid": "a80e2788-c6e3-46ce-955b-5bef549c5386", "name": "load_p1rlv11523_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69eba934-3f80-4abc-b5e8-9cdc79aa05a3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4899fddb-d844-4080-b45a-7bccd4a40de6"}}}}, {"uuid": "65d4d5d7-783c-4164-9c8c-6c80d4c32877", "name": "fbee6fff-73fa-44c2-88bb-e8f585e06115_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.560490892963857, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.302618625091914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10815e19-d32c-4147-a949-9fef4a5bc497", "name": "4ab78c27-a37e-49bf-b595-8b2419cac41f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "65d4d5d7-783c-4164-9c8c-6c80d4c32877"}}}]}, {"uuid": "d8524e9d-cf8b-47cd-92c0-a98c04a69555", "name": "load_p1rlv11526_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b97ebb0-09a4-4c42-a10e-e3aff344aa44"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10815e19-d32c-4147-a949-9fef4a5bc497"}}}}, {"uuid": "51e5b752-3e23-46c1-9104-8d1d07336b1f", "name": "088aeaee-f16d-455b-b6d9-55ceb9ab8cb3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.560490892963857, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.302618625091914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d2e76bd6-ce54-4e45-afc2-c40a892add08", "name": "88cdaf35-1444-46f0-8a69-9a7b75dfe1b2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "51e5b752-3e23-46c1-9104-8d1d07336b1f"}}}]}, {"uuid": "262f3cf0-072f-4bb0-ae69-bed19095daee", "name": "load_p1rlv11526_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b97ebb0-09a4-4c42-a10e-e3aff344aa44"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d2e76bd6-ce54-4e45-afc2-c40a892add08"}}}}, {"uuid": "081b87d0-9953-4e94-a14c-6869f5aff188", "name": "9e28f35b-2950-4018-b931-ce4c4c0e68c5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.930214175792893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.08514782397789, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c4f46244-6662-4298-a101-badc385e322a", "name": "a13bffde-fdec-4d49-9362-91ba5f7576b4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "081b87d0-9953-4e94-a14c-6869f5aff188"}}}]}, {"uuid": "9a43a335-3b65-4527-a2e0-01cfe39458a8", "name": "load_p1rlv11533_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21b18539-fba6-4b52-b8bf-38c2a6c4abfb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c4f46244-6662-4298-a101-badc385e322a"}}}}, {"uuid": "99521e7b-f1a6-438c-98d8-173782182e76", "name": "bab3eb24-732d-46b7-8d01-cd470539adfe_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.930214175792893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.08514782397789, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4fd952c7-7b2a-4e24-9952-342418d3823b", "name": "9ff22554-db4e-4376-8f63-da8436d1a4e4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "99521e7b-f1a6-438c-98d8-173782182e76"}}}]}, {"uuid": "8b08b8fd-c3d6-4cf2-84f5-3a95d96b51ad", "name": "load_p1rlv11533_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21b18539-fba6-4b52-b8bf-38c2a6c4abfb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4fd952c7-7b2a-4e24-9952-342418d3823b"}}}}, {"uuid": "ddf295d3-4ca7-45b8-bab0-2d2bedc79adf", "name": "164eb96d-8724-440d-841e-984dfc18b446_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.679125701108364, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8113232260660387, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "11b71362-a9ff-4ef3-91d7-b68749e0d98c", "name": "ae9b73d9-29a3-4d82-a958-b574c12d172e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ddf295d3-4ca7-45b8-bab0-2d2bedc79adf"}}}]}, {"uuid": "0920b786-6c42-4116-a887-236dade23449", "name": "load_p1rlv11540_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f79b14c8-e77d-49c1-9336-e7407ad4c94d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "11b71362-a9ff-4ef3-91d7-b68749e0d98c"}}}}, {"uuid": "8e30adb3-f06b-4cd3-bb78-0d53c73b9a12", "name": "a65e0dea-444d-422c-859a-f131dddcc40d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.679125701108364, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8113232260660387, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5b1b211b-f5c6-4161-9358-4937f7abcf73", "name": "9a4b4965-a41b-4d43-a8a7-48fa3accb31f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8e30adb3-f06b-4cd3-bb78-0d53c73b9a12"}}}]}, {"uuid": "e4f076a8-8c21-4468-995f-cb3d3a523c31", "name": "load_p1rlv11540_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f79b14c8-e77d-49c1-9336-e7407ad4c94d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5b1b211b-f5c6-4161-9358-4937f7abcf73"}}}}, {"uuid": "4fa4e50c-0268-4490-9d23-af532cb741af", "name": "ed9a947f-533f-4db7-9220-295975ae80ed_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c32e1d70-5898-46d9-bdfe-474a13392868", "name": "68ccf7df-d110-494b-be42-8264b9530d4d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4fa4e50c-0268-4490-9d23-af532cb741af"}}}]}, {"uuid": "4c5802e3-88ed-4e3e-929b-910aeb4c85f1", "name": "load_p1rlv13033_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1564c5f9-8b80-41b4-af09-2a55dee0718b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c32e1d70-5898-46d9-bdfe-474a13392868"}}}}, {"uuid": "ce96a1c1-4da1-4feb-ab24-94101677e52a", "name": "ac092c22-a341-4f4b-8b0e-06392057556b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "629c4abf-b246-4c2f-be64-fc45ce958904", "name": "2dca5672-682f-4a17-8c6a-9c7e92a4b7c3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ce96a1c1-4da1-4feb-ab24-94101677e52a"}}}]}, {"uuid": "ad7a7ba1-03a7-421c-af74-453a372d2ea2", "name": "load_p1rlv13033_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1564c5f9-8b80-41b4-af09-2a55dee0718b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "629c4abf-b246-4c2f-be64-fc45ce958904"}}}}, {"uuid": "c09b2358-e1d4-413e-b86c-89d5aeea06c6", "name": "709debc3-2c8b-473c-b17c-aa380a193726_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.074192704000552, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.129078804753558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a399b34-ceb0-4ca8-ab6b-fbeb5d6f11c7", "name": "2f4af060-e488-4b5c-bbdc-53115064906c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c09b2358-e1d4-413e-b86c-89d5aeea06c6"}}}]}, {"uuid": "8a1dd38f-312a-47da-905c-79698fc4f27c", "name": "load_p1rlv13034_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3b7bff1-90da-4ee2-8a0f-8e291a7e8ac8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a399b34-ceb0-4ca8-ab6b-fbeb5d6f11c7"}}}}, {"uuid": "223ca125-2a2e-42c1-a0f0-1828dd36ffba", "name": "5cbc8aa5-1d48-4762-9892-454566c93f99_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.074192704000552, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.129078804753558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a6972633-51d9-4e1e-be81-d289073144bd", "name": "4f0c4078-005c-4e05-a7c1-0bc96ee69bb0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "223ca125-2a2e-42c1-a0f0-1828dd36ffba"}}}]}, {"uuid": "fb379ee7-427c-476e-ac35-a702194e4e69", "name": "load_p1rlv13034_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3b7bff1-90da-4ee2-8a0f-8e291a7e8ac8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a6972633-51d9-4e1e-be81-d289073144bd"}}}}, {"uuid": "138ba538-6925-4490-b7f9-acb50c759789", "name": "3c7fb123-b99c-46f9-9eec-1cafe1d9f2e8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8791002615066037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24190904367644575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50264ea1-2130-4ac4-8d83-06f7624bd00e", "name": "44c01c96-1d1c-4b12-a737-fa38d53e233c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "138ba538-6925-4490-b7f9-acb50c759789"}}}]}, {"uuid": "349eb58c-b111-4f6d-92c2-159ecb9b146c", "name": "load_p1rlv13035_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6d309ef-b082-4022-a265-4891cdcd6db9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50264ea1-2130-4ac4-8d83-06f7624bd00e"}}}}, {"uuid": "b87dfe47-5295-4a04-b72a-5be002a781e1", "name": "6e915124-e0ea-436f-9543-a77188bab4cd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8791002615066037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24190904367644575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2fa5a665-5deb-467b-bc9f-e71f2bfdf9cf", "name": "bee7ab42-c47c-4c2f-8de9-ccab5a61c6bf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b87dfe47-5295-4a04-b72a-5be002a781e1"}}}]}, {"uuid": "e46287b6-7827-4592-b1f2-e687e6f7c00a", "name": "load_p1rlv13035_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6d309ef-b082-4022-a265-4891cdcd6db9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2fa5a665-5deb-467b-bc9f-e71f2bfdf9cf"}}}}, {"uuid": "b1401c39-ec75-4e7a-8caa-59de8c4e3727", "name": "7ec60f8a-d974-4b77-92e3-6cbdb06326b0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.131827489381682, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6495252596209705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "99ced9d6-782f-4da9-9093-b8b75d9454c2", "name": "19e9f87e-4cc7-4702-8545-744ffab5f522", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b1401c39-ec75-4e7a-8caa-59de8c4e3727"}}}]}, {"uuid": "74249f5e-7c0c-44ef-a2be-d9cadb9b8d06", "name": "load_p1rlv13036_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23aae8f1-8b9f-4453-9643-b49ffdc80889"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "99ced9d6-782f-4da9-9093-b8b75d9454c2"}}}}, {"uuid": "bb7a935e-ef3f-4259-9dce-2efb49419534", "name": "8451fc2b-9ede-464e-80ad-cec49e4e429f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.131827489381682, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6495252596209705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5a4776db-fe9d-4c72-b386-e630b5d5e0c9", "name": "c75f3183-02be-4b10-b581-a012f3bdcff2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bb7a935e-ef3f-4259-9dce-2efb49419534"}}}]}, {"uuid": "d0d08220-f82e-4813-9e86-d7f5cb6054e5", "name": "load_p1rlv13036_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23aae8f1-8b9f-4453-9643-b49ffdc80889"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5a4776db-fe9d-4c72-b386-e630b5d5e0c9"}}}}, {"uuid": "77d82711-d253-462f-9ce5-586d5710551c", "name": "d87b062f-7549-4bee-af82-d39450b08042_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5976710782342964, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7583664749710641, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "671b0544-3d59-4a1b-8ec2-057c16dd2d81", "name": "05306373-07f2-441b-a327-a67270b22e0d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "77d82711-d253-462f-9ce5-586d5710551c"}}}]}, {"uuid": "15c35e98-5054-4b11-b7b4-e8429f0b12fc", "name": "load_p1rlv13037_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f5d04aa-74fb-4d1a-ac91-6c01a56a94b5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "671b0544-3d59-4a1b-8ec2-057c16dd2d81"}}}}, {"uuid": "f31d5dca-c798-4cd4-b33b-6ef36ff34bc7", "name": "7dbc7a03-397e-4144-b496-f0c6fa124214_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5976710782342964, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7583664749710641, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a3e03fb2-566e-4710-a10c-7991ba3eeca0", "name": "4280b610-705e-4bf3-ba2f-30e609aa9084", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f31d5dca-c798-4cd4-b33b-6ef36ff34bc7"}}}]}, {"uuid": "1cd6f0e8-61a1-4056-9be8-650d4ddfb3c8", "name": "load_p1rlv13037_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f5d04aa-74fb-4d1a-ac91-6c01a56a94b5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a3e03fb2-566e-4710-a10c-7991ba3eeca0"}}}}, {"uuid": "79a2c1dd-04cb-47c4-aea3-5ad30f4dd768", "name": "635abd80-13c7-475c-af2d-43f4c81f0b5c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3798783675992279, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6151141774255103, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "74679bbb-a484-4253-95c3-882a57fe12a8", "name": "7a58bd99-3ac7-4f56-92ae-cdd643b0c927", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "79a2c1dd-04cb-47c4-aea3-5ad30f4dd768"}}}]}, {"uuid": "5502f1c8-b1b7-4e4b-a292-e5983d56926a", "name": "load_p1rlv13038_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a8b4502-31fd-4dce-8717-9860880075b4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "74679bbb-a484-4253-95c3-882a57fe12a8"}}}}, {"uuid": "8ad46779-2f5a-4b34-9123-594b28c7eef7", "name": "5dce28a7-bf93-405d-8b27-8d86926ff647_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3798783675992279, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6151141774255103, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fe24ccb4-a072-4c0e-9c69-7397187c0cf7", "name": "4477297e-dda0-42e2-bb36-9d0b9e1a7d1a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ad46779-2f5a-4b34-9123-594b28c7eef7"}}}]}, {"uuid": "b4ade9d1-a099-4144-8c8f-1313629a488b", "name": "load_p1rlv13038_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a8b4502-31fd-4dce-8717-9860880075b4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fe24ccb4-a072-4c0e-9c69-7397187c0cf7"}}}}, {"uuid": "f0d3a250-3125-47eb-beed-cb4d47fa06b4", "name": "177b4262-69d7-456e-a722-ddb895f56358_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9179777962446224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3481400399277513, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4bbd2f71-2995-4f3a-8fa8-bbdbc13b5f7b", "name": "e4ad0457-669c-4703-8935-20a525526720", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f0d3a250-3125-47eb-beed-cb4d47fa06b4"}}}]}, {"uuid": "8016b94a-61cd-4674-9c60-0410c68b8445", "name": "load_p1rlv13039_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34d43081-e4a3-4f1b-8b90-5965458452d0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4bbd2f71-2995-4f3a-8fa8-bbdbc13b5f7b"}}}}, {"uuid": "07e8ba08-4868-403a-8a82-8ca90c974837", "name": "b8559d4c-4ddd-4d69-af4d-82e49146b816_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9179777962446224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3481400399277513, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4d0f1690-75ce-4f79-9841-9acb4c42984c", "name": "5287314b-d1e0-4ade-b0b3-387b6329da2c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "07e8ba08-4868-403a-8a82-8ca90c974837"}}}]}, {"uuid": "b9f95b3b-f26e-4c6a-a080-a497e15d7e02", "name": "load_p1rlv13039_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34d43081-e4a3-4f1b-8b90-5965458452d0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4d0f1690-75ce-4f79-9841-9acb4c42984c"}}}}, {"uuid": "e29843ac-90b9-437c-9117-ccf066515291", "name": "29e3febd-4892-42b4-b287-c9ebfb418d08_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4464370236076721, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16599396793014964, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "03f4d81e-7c78-4db0-89f5-bee053df019a", "name": "d4430213-5d8e-4f92-af83-09a386b39a7e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e29843ac-90b9-437c-9117-ccf066515291"}}}]}, {"uuid": "c9b00953-9433-444e-a5c9-287baab06620", "name": "load_p1rlv13040_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6839f65-9d3b-4bd6-89a4-0c8feb33e98a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "03f4d81e-7c78-4db0-89f5-bee053df019a"}}}}, {"uuid": "2e0477a3-1ea7-4d91-81c7-3e83d4dea658", "name": "ecf11542-81c2-4406-a311-e724aa04cf7a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4464370236076721, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16599396793014964, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ddcc766b-ec42-4d26-bd83-7ddc9efec038", "name": "8083a4d1-79d3-4022-9268-102584301916", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2e0477a3-1ea7-4d91-81c7-3e83d4dea658"}}}]}, {"uuid": "09a05117-9020-4a21-8ab8-0ef14c99c774", "name": "load_p1rlv13040_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6839f65-9d3b-4bd6-89a4-0c8feb33e98a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ddcc766b-ec42-4d26-bd83-7ddc9efec038"}}}}, {"uuid": "9fd53137-bf5a-4f5f-a0b4-8276d87bb04e", "name": "6c17db69-bff2-4e56-a3c1-bb3723cd6918_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6434260893942235, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2588956175598443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3782e5b3-e7f7-4d7f-b4b4-58875e227199", "name": "f2e69ca8-aaf9-43be-9bee-272320ab0e80", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9fd53137-bf5a-4f5f-a0b4-8276d87bb04e"}}}]}, {"uuid": "1e04bc67-8ff5-44ca-8784-51571cb550f5", "name": "load_p1rlv13041_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60144ce1-d4d6-4725-b543-f881894356a5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3782e5b3-e7f7-4d7f-b4b4-58875e227199"}}}}, {"uuid": "30335b57-8e08-4154-960d-cdb9c5ede14d", "name": "6231824f-1b85-4d24-800d-f11202944c11_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6434260893942235, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2588956175598443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "119a9724-a20e-416d-809e-b714471622b9", "name": "184a31ea-7142-4290-9059-ff71e29618bd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "30335b57-8e08-4154-960d-cdb9c5ede14d"}}}]}, {"uuid": "d020a635-aab4-4f6b-83b6-a53650efb072", "name": "load_p1rlv13041_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60144ce1-d4d6-4725-b543-f881894356a5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "119a9724-a20e-416d-809e-b714471622b9"}}}}, {"uuid": "55db8cce-9446-48f3-8af9-62589b3bd742", "name": "b428e6d6-918d-4b4d-971d-7391125b8f9b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4148353854888571, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6393114443430603, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "294d20fe-cf8c-46f0-9f89-0657ecce2434", "name": "deaccebf-96cd-40dd-b573-7ca8f71d8aa1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "55db8cce-9446-48f3-8af9-62589b3bd742"}}}]}, {"uuid": "d794cf69-32cb-405e-aea3-c90086351290", "name": "load_p1rlv13042_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "296cd07e-c2e3-4031-abad-9c870a65105d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "294d20fe-cf8c-46f0-9f89-0657ecce2434"}}}}, {"uuid": "9eb257c7-77e7-41ba-b202-3ff32c0bae0f", "name": "32b13cdb-a6a7-4fa4-9149-82f44136ffe0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4148353854888571, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6393114443430603, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bd71a0f0-6c1d-48ed-bf4a-8de6a137936e", "name": "8f98108c-29bd-4c2f-ad46-00c13335eece", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9eb257c7-77e7-41ba-b202-3ff32c0bae0f"}}}]}, {"uuid": "3d035aed-8608-46c0-983e-7d889e4949f9", "name": "load_p1rlv13042_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "296cd07e-c2e3-4031-abad-9c870a65105d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bd71a0f0-6c1d-48ed-bf4a-8de6a137936e"}}}}, {"uuid": "425e2de3-13e4-4801-a064-4d6ab2e349ce", "name": "2aafb20a-ab3e-4270-8650-395ae93416dd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.478593979285423, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7308840963144931, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "291002f8-5c77-41b0-b8e0-60cd4dbfc1da", "name": "e96ce69e-4a0b-451e-beb7-464af7b99a7f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "425e2de3-13e4-4801-a064-4d6ab2e349ce"}}}]}, {"uuid": "f7547184-7196-4c0c-9432-e18539ec7017", "name": "load_p1rlv13513_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3243ca2f-a97e-4fbc-981d-85eded2e5e6b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "291002f8-5c77-41b0-b8e0-60cd4dbfc1da"}}}}, {"uuid": "fed2bcf4-ae62-4152-aa92-ec9cbf205825", "name": "f582a945-a569-495f-b213-31a28a011ac9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.478593979285423, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7308840963144931, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f12ac523-0ead-4cbf-969c-b26ceaaeec58", "name": "eb431eed-b218-4601-9fa7-f4a8dabafcff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fed2bcf4-ae62-4152-aa92-ec9cbf205825"}}}]}, {"uuid": "737befe8-c05e-4ae8-baf6-f2e2a1d20f28", "name": "load_p1rlv13513_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3243ca2f-a97e-4fbc-981d-85eded2e5e6b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f12ac523-0ead-4cbf-969c-b26ceaaeec58"}}}}, {"uuid": "1a5b8ef6-4d4b-4207-aaae-0b8a6562ae2c", "name": "e127eac9-8755-4774-a29d-89f9e6b418a0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.516258392707745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.82351986644914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "03330f10-9cb3-42e2-aef8-e02084fc5dec", "name": "a8790ecc-0157-4088-82d4-7aa10c681ebb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1a5b8ef6-4d4b-4207-aaae-0b8a6562ae2c"}}}]}, {"uuid": "059c3995-844d-453c-932d-52647f7dbc4c", "name": "load_p1rlv13789_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47a7519a-b550-41e6-99e3-c2115db425fe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "03330f10-9cb3-42e2-aef8-e02084fc5dec"}}}}, {"uuid": "2e22c9e7-f048-46f8-bc69-5861cfd05527", "name": "8c2a521a-38cb-4686-8fa9-386999634546_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.516258392707745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.82351986644914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eae585db-5e8d-4d76-8203-27d0420f79b4", "name": "188cd438-df8d-4b24-b92d-fddfbb0a2ebe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2e22c9e7-f048-46f8-bc69-5861cfd05527"}}}]}, {"uuid": "5cf01015-ea31-4da1-939a-778efe5c2762", "name": "load_p1rlv13789_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47a7519a-b550-41e6-99e3-c2115db425fe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eae585db-5e8d-4d76-8203-27d0420f79b4"}}}}, {"uuid": "15995836-e2ba-4cf9-b118-fff27f395444", "name": "a6f8ebb6-0854-4d92-9356-401305b2a257_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3786182488338723, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5359363058124609, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6151c915-f4c7-4240-b24d-ee4967125fff", "name": "08169670-c1b9-4102-9b44-fc13d2303d0c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "15995836-e2ba-4cf9-b118-fff27f395444"}}}]}, {"uuid": "4e713549-1fcf-420c-ba99-1a57feebc8e5", "name": "load_p1rlv13791_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "251f270f-4238-4fe6-8ab3-f884fca7a42d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6151c915-f4c7-4240-b24d-ee4967125fff"}}}}, {"uuid": "7dfb398c-2767-42a5-a503-e4c1a92dab37", "name": "787f56e7-2686-4704-aafa-30bc043d4c7d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3786182488338723, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5359363058124609, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "01d1aabe-0a01-4e59-a48f-7c981a2fdc1a", "name": "22519096-b6e1-40e2-975d-736497e787ed", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7dfb398c-2767-42a5-a503-e4c1a92dab37"}}}]}, {"uuid": "db355cce-248a-4b61-815d-b564ae9f0424", "name": "load_p1rlv13791_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "251f270f-4238-4fe6-8ab3-f884fca7a42d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "01d1aabe-0a01-4e59-a48f-7c981a2fdc1a"}}}}, {"uuid": "5b2c074c-c20e-4eab-b9a8-e92b48974001", "name": "8fde2c8d-0b7d-43c0-b5e3-9724c9e6f07c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4950137537296666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31506625700854357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5c88bd25-3fea-4b53-a5c3-29d534c2286e", "name": "86a0e8fc-47a8-451c-b70d-2cb2c944eb6e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b2c074c-c20e-4eab-b9a8-e92b48974001"}}}]}, {"uuid": "2bb93d01-77c6-4fb0-b5b0-918cc6184ea8", "name": "load_p1rlv13796_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94ac9254-cdbf-4864-b22b-bcfb0a827700"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5c88bd25-3fea-4b53-a5c3-29d534c2286e"}}}}, {"uuid": "eb63e254-b796-476a-afba-e8ebb47b74e4", "name": "cf5e3c94-b0f7-462e-a355-b258ae53f695_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4950137537296666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31506625700854357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "23da9e2b-d468-4008-b47f-d63d8c87dadb", "name": "6a1fe7ff-ccbd-46ac-b9ad-285f127c3344", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eb63e254-b796-476a-afba-e8ebb47b74e4"}}}]}, {"uuid": "2f75fc92-6b34-4785-8154-8f0b31b77142", "name": "load_p1rlv13796_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94ac9254-cdbf-4864-b22b-bcfb0a827700"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "23da9e2b-d468-4008-b47f-d63d8c87dadb"}}}}, {"uuid": "62825484-a85f-4497-9f3f-aa09f9016fe1", "name": "52fad3e9-45c9-4056-a73b-cb0e42e846c1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.008167500419157, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.871384812064858, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "40ad2075-2f27-43f9-bf26-24398179c740", "name": "15638478-3799-4f8d-a195-0cf7ad60607a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "62825484-a85f-4497-9f3f-aa09f9016fe1"}}}]}, {"uuid": "8e3b48bc-f743-4918-a2a8-d5c73997b5a5", "name": "load_p1rlv13801_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "accec892-a236-462d-b714-1178393ec992"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "40ad2075-2f27-43f9-bf26-24398179c740"}}}}, {"uuid": "da810e7f-f506-45e9-913d-f97a58abd11e", "name": "648f7673-2b7c-4917-9c63-f95e75196436_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.008167500419157, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.871384812064858, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1f8ea155-e6d1-4317-8ea6-a50f177cd91d", "name": "6e917f1f-4044-42e1-adfd-a0279c5d3d2d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "da810e7f-f506-45e9-913d-f97a58abd11e"}}}]}, {"uuid": "a0320d1d-20ae-462f-9746-521cd612a5bd", "name": "load_p1rlv13801_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "accec892-a236-462d-b714-1178393ec992"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1f8ea155-e6d1-4317-8ea6-a50f177cd91d"}}}}, {"uuid": "888affa1-c032-49bf-b439-d454732e868e", "name": "aa1d1c01-f032-40a4-85be-478812f1eec9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7055277650263714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24030088917661724, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f3390525-aa36-4b5e-b5c7-05b031722646", "name": "ac90927c-2c18-439c-9388-1849753638b9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "888affa1-c032-49bf-b439-d454732e868e"}}}]}, {"uuid": "0f26d234-dc12-4b26-9669-c0cc9f06d569", "name": "load_p1rlv13807_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c26fba44-3b81-47de-81e6-522f2daf0534"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f3390525-aa36-4b5e-b5c7-05b031722646"}}}}, {"uuid": "e816eb48-5381-4aa3-8477-15717e4343b5", "name": "3f3c2bee-1196-4b7f-aa9a-6b7f6163e03a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7055277650263714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24030088917661724, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "67b6d902-8b82-47cf-a989-f252d66071a4", "name": "4f177047-2b91-4fcc-aee1-b7321b7be182", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e816eb48-5381-4aa3-8477-15717e4343b5"}}}]}, {"uuid": "6d8a4cc7-ad2d-4b8e-9bdf-c6ca602aad0c", "name": "load_p1rlv13807_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c26fba44-3b81-47de-81e6-522f2daf0534"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "67b6d902-8b82-47cf-a989-f252d66071a4"}}}}, {"uuid": "d1cf8902-36ff-4259-8e06-9c26e6496790", "name": "4d637426-9411-4538-9c9c-90c7616f7121_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5041010955030301, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21577690333785765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4459f193-4f92-46a4-8eed-add2c2837094", "name": "95fb1d20-7bb6-49df-901a-9410ab8b79e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d1cf8902-36ff-4259-8e06-9c26e6496790"}}}]}, {"uuid": "3e004b64-3af9-48f6-9dfd-fc8b13172d45", "name": "load_p1rlv13808_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c795ac7-3b49-4158-996d-2fb1f0337847"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4459f193-4f92-46a4-8eed-add2c2837094"}}}}, {"uuid": "2f4c2dc2-6bdb-4037-90cb-691a2702b98b", "name": "958bc998-f198-4634-9716-9c72eefb2a1c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5041010955030301, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21577690333785765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "27270979-b92b-4d35-af3a-2c0e04df552b", "name": "0c08438e-daba-4da3-a5dc-db54fa184471", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2f4c2dc2-6bdb-4037-90cb-691a2702b98b"}}}]}, {"uuid": "74ab9452-4a60-4e6f-8072-464d74ee30df", "name": "load_p1rlv13808_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c795ac7-3b49-4158-996d-2fb1f0337847"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "27270979-b92b-4d35-af3a-2c0e04df552b"}}}}, {"uuid": "09eac509-8dac-41fe-9bce-64d8745425df", "name": "7dd53474-539f-4945-ac4c-c735c42112a5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0716753053645807, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8046017922971841, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "595de68a-b010-43ba-b21e-cc78f49bf48c", "name": "f02bea0f-dbc3-4422-a398-93888ea0def0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "09eac509-8dac-41fe-9bce-64d8745425df"}}}]}, {"uuid": "5c7db3cf-10d4-4267-8217-45a53afc7161", "name": "load_p1rlv13809_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "687996da-ab03-4544-b0d9-b79b8ac88e95"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "595de68a-b010-43ba-b21e-cc78f49bf48c"}}}}, {"uuid": "e5a9e2ec-ffef-4651-b51a-9f5316c82fb3", "name": "d7ece7d1-ce61-48ea-9df6-aa24014abecc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0716753053645807, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8046017922971841, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "efe80323-ab9b-4e01-815f-7fd0ce6c61df", "name": "92358e67-308f-4f32-b27a-e88559370266", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e5a9e2ec-ffef-4651-b51a-9f5316c82fb3"}}}]}, {"uuid": "0f2cf445-d144-43b5-80e0-38fd27f20829", "name": "load_p1rlv13809_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "687996da-ab03-4544-b0d9-b79b8ac88e95"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "efe80323-ab9b-4e01-815f-7fd0ce6c61df"}}}}, {"uuid": "764a156c-e82c-4978-9206-f52ce77f1f99", "name": "c1836a03-add8-4694-8d66-c2a6ed431151_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2437684685157903, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09956111056866535, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ae3347f6-7775-4433-814b-7ba9513e963e", "name": "bd38cf53-e217-4b92-a4c4-d1ffe15199df", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "764a156c-e82c-4978-9206-f52ce77f1f99"}}}]}, {"uuid": "55eed416-e9d9-4d58-8026-22b2f3f7cfe3", "name": "load_p1rlv13810_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab29ca66-d59b-4aa6-b5f6-165add0bc331"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ae3347f6-7775-4433-814b-7ba9513e963e"}}}}, {"uuid": "5cb79924-30c9-43e2-9a96-729fd0ac694c", "name": "3debea35-c388-41e2-83e2-aa90977b6cc3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2437684685157903, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09956111056866535, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2e0910b7-f02c-4d0e-bf15-f0b81921172f", "name": "f99681c6-3e7c-4c69-85c3-db72b795048f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5cb79924-30c9-43e2-9a96-729fd0ac694c"}}}]}, {"uuid": "8c2da7f0-f23d-49e5-a56f-820d68cb01a9", "name": "load_p1rlv13810_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab29ca66-d59b-4aa6-b5f6-165add0bc331"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2e0910b7-f02c-4d0e-bf15-f0b81921172f"}}}}, {"uuid": "8982f43c-2ab5-484c-91cd-8e23d4654b47", "name": "072f3713-115a-432e-b689-83fa9f6ad36d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.291842017688742, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7877197601951852, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0e13e8a7-69f7-4384-b6c2-6f9ab0821da4", "name": "a275ccd5-d06c-427c-b582-d3fa7d408111", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8982f43c-2ab5-484c-91cd-8e23d4654b47"}}}]}, {"uuid": "77fbe0a1-4002-4304-b6e3-b6284061bd2f", "name": "load_p1rlv13814_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028d5ead-7c34-400b-bcc1-c4d706c965d3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0e13e8a7-69f7-4384-b6c2-6f9ab0821da4"}}}}, {"uuid": "9c01f881-0f25-4d6f-a0dd-993098bd49f3", "name": "f2d86489-1f92-4a87-bfff-a752fdc6953b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.291842017688742, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7877197601951852, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d84a97b2-613d-4893-b775-76dcb6d72baf", "name": "beb70e77-2905-4532-b661-ae7947ab1dd9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9c01f881-0f25-4d6f-a0dd-993098bd49f3"}}}]}, {"uuid": "725fc8ff-fe31-4c43-a721-a77c74959288", "name": "load_p1rlv13814_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028d5ead-7c34-400b-bcc1-c4d706c965d3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d84a97b2-613d-4893-b775-76dcb6d72baf"}}}}, {"uuid": "9485e0ab-76b3-4249-95c6-c9694fbcc55f", "name": "186fb67b-61b4-4e51-85e1-ea65bdfd5178_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5478654763148745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5646840796232575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82a2547d-e285-4e42-9a0d-ba17743e95e5", "name": "c4052cf7-690b-460a-9695-67409665f911", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9485e0ab-76b3-4249-95c6-c9694fbcc55f"}}}]}, {"uuid": "61cacffc-8e4f-446d-9a8a-931f9727a422", "name": "load_p1rlv13815_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99957459-46a6-4b2b-9813-69b11ca7dad1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "82a2547d-e285-4e42-9a0d-ba17743e95e5"}}}}, {"uuid": "66b8279c-9e1c-45f4-b507-e46cf979f5c6", "name": "191437de-ee79-45c6-be63-1bbce4377cfc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5478654763148745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5646840796232575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6ef4d2cf-ba8f-4ed5-8ce4-e3056b1156af", "name": "c7fff845-744f-4630-aa26-cd67a5961399", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "66b8279c-9e1c-45f4-b507-e46cf979f5c6"}}}]}, {"uuid": "76a08ec6-32a3-435c-9c52-2118ff199523", "name": "load_p1rlv13815_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99957459-46a6-4b2b-9813-69b11ca7dad1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6ef4d2cf-ba8f-4ed5-8ce4-e3056b1156af"}}}}, {"uuid": "a17c41d6-24e9-4b26-b9f9-de67964bb309", "name": "874e3fbd-6b4d-407a-8383-51ddc0d9aef7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0085854932437286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7150296414254909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "81850b27-a9b8-4fab-b10e-81a89ac0bc87", "name": "fc960aa0-6058-4889-b9e8-5a07b2878577", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a17c41d6-24e9-4b26-b9f9-de67964bb309"}}}]}, {"uuid": "f8444c20-8eea-40ac-a488-93a9711e5ff0", "name": "load_p1rlv13817_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e96bcc5b-07c5-4289-aec4-0224395c5e8a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "81850b27-a9b8-4fab-b10e-81a89ac0bc87"}}}}, {"uuid": "d54c2be7-a14b-4aef-8853-4acd41e72c47", "name": "3c0522c5-f6f6-4b47-a464-522778742137_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0085854932437286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7150296414254909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "12e364e5-acfd-4e1d-89f6-21c9acd3d848", "name": "d620051e-a9a4-445e-aa26-8eca2cc48ec2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d54c2be7-a14b-4aef-8853-4acd41e72c47"}}}]}, {"uuid": "010ca500-2acf-4ce6-a039-674b272f9de8", "name": "load_p1rlv13817_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e96bcc5b-07c5-4289-aec4-0224395c5e8a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "12e364e5-acfd-4e1d-89f6-21c9acd3d848"}}}}, {"uuid": "4ed34c37-e2e9-4a65-a903-8a7caf11552c", "name": "78d7d066-06b1-4597-8e7d-fbf0e4036139_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1381537134701794, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42848704523913217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c0b7b5ac-4a0b-49c2-92c7-27cadd156772", "name": "aebf1b77-f7cf-43a9-a950-21464c55fb9e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4ed34c37-e2e9-4a65-a903-8a7caf11552c"}}}]}, {"uuid": "a8a6ea27-b4a4-4d06-8c4f-af8f1127daad", "name": "load_p1rlv13819_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36c12a74-a2ca-439a-a69f-308dd5cb1207"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c0b7b5ac-4a0b-49c2-92c7-27cadd156772"}}}}, {"uuid": "781fe3f1-6b6c-48b9-abd9-77d5b7369aae", "name": "5f1443a2-975b-4cb0-86c4-0b677d3a55db_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1381537134701794, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42848704523913217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "35ede9f1-60a6-4d8d-9701-723de6433418", "name": "efef0562-da88-4e42-aade-749922d559fa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "781fe3f1-6b6c-48b9-abd9-77d5b7369aae"}}}]}, {"uuid": "109422e2-02b7-4e4c-a09f-06afab81a341", "name": "load_p1rlv13819_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36c12a74-a2ca-439a-a69f-308dd5cb1207"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "35ede9f1-60a6-4d8d-9701-723de6433418"}}}}, {"uuid": "66d4d596-e4c7-4a54-a4e6-38df808f0693", "name": "14e258f3-02bd-4e24-95a2-41a1a66bfdb7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.3612796720379805, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.3972907909814523, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a31f4fb0-d83d-4ad1-86a9-4cfdf5a4bee9", "name": "9b2c0e73-1ff0-4035-bd34-92cd7d49c9be", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "66d4d596-e4c7-4a54-a4e6-38df808f0693"}}}]}, {"uuid": "85c9ad07-5dc3-47c3-aa58-1945480e5aff", "name": "load_p1rlv13820_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a2caa70b-9143-4676-834b-bfc7cb41330c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a31f4fb0-d83d-4ad1-86a9-4cfdf5a4bee9"}}}}, {"uuid": "b927f7b1-4142-4df3-a0fa-95a333a7982f", "name": "2a448f2a-f40c-4c5d-bd9f-5e1dc505e62d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.3612796720379805, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.3972907909814523, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bc7e8ec9-7648-41d1-8858-e4c8ddaaef33", "name": "98b412f3-26ab-4cfa-a65f-55021acba615", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b927f7b1-4142-4df3-a0fa-95a333a7982f"}}}]}, {"uuid": "d09ba371-5421-4487-90ee-5e8bfd642999", "name": "load_p1rlv13820_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a2caa70b-9143-4676-834b-bfc7cb41330c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bc7e8ec9-7648-41d1-8858-e4c8ddaaef33"}}}}, {"uuid": "ad98ac11-5d4c-4742-b631-47f8b8ad5445", "name": "ab8854ef-b22e-4714-8819-41beee60bb75_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.635130525488038, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.332876746135676, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a8dbac4e-81f6-40fa-8b95-8d36357946af", "name": "4d40fbdc-7093-474b-be43-a3bb70b4d5ff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ad98ac11-5d4c-4742-b631-47f8b8ad5445"}}}]}, {"uuid": "d501dc5e-ac3c-457d-9bc2-ea5a144144eb", "name": "load_p1rlv13821_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66e6c732-919a-4851-9f76-5580ea71669d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a8dbac4e-81f6-40fa-8b95-8d36357946af"}}}}, {"uuid": "8f0e7ca1-035f-45eb-b40d-b347ef767d4f", "name": "ca440c4c-f25c-4309-98c9-edf583c1ec98_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.635130525488038, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.332876746135676, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "57e80d64-eb9a-4869-acfa-665c994e1148", "name": "8ae6d28a-801a-45b2-8390-e0422e4f9124", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8f0e7ca1-035f-45eb-b40d-b347ef767d4f"}}}]}, {"uuid": "a78a4b78-fc95-4288-bc8f-85602712d6c7", "name": "load_p1rlv13821_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66e6c732-919a-4851-9f76-5580ea71669d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "57e80d64-eb9a-4869-acfa-665c994e1148"}}}}, {"uuid": "355253ea-407d-4eb0-9b8d-c609e3b8b8cc", "name": "6ebb2d5e-69fc-474d-bda3-d3b44a463d0c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7812856221781264, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.29493523962554685, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ff2e9217-8807-434d-a450-744efe345e72", "name": "3752c325-d5c2-4d40-8e38-7b04fc71177a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "355253ea-407d-4eb0-9b8d-c609e3b8b8cc"}}}]}, {"uuid": "68efcac0-34fe-4dd9-a0e2-fe0c3d757d94", "name": "load_p1rlv13822_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ade9991-a857-4619-8094-c18f824aaeb9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ff2e9217-8807-434d-a450-744efe345e72"}}}}, {"uuid": "6bd0f62f-8edf-4810-99be-e798cac24cf2", "name": "356dfa36-fd2a-4a57-8e5d-1a9549308602_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7812856221781264, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.29493523962554685, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6407febc-5c2c-4ba9-803c-40af9378c220", "name": "32c9cd48-906e-4915-b516-d48f6bb09d2c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6bd0f62f-8edf-4810-99be-e798cac24cf2"}}}]}, {"uuid": "4da4f5d5-66ee-4fcb-aea2-ce75b8f24a11", "name": "load_p1rlv13822_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ade9991-a857-4619-8094-c18f824aaeb9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6407febc-5c2c-4ba9-803c-40af9378c220"}}}}, {"uuid": "46b7186f-23aa-404f-89fe-b1da22b8988b", "name": "71a40a7d-0b07-4707-9fc8-7453aa248bbb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1222862909492073, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34523553920221683, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c03ecb1d-7a8d-432a-87f1-649a7a2c0bd8", "name": "9143989a-51bb-4e7f-bbaf-2e6f00feef4c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "46b7186f-23aa-404f-89fe-b1da22b8988b"}}}]}, {"uuid": "b18c5017-b58a-4d8e-99df-186b1dba584a", "name": "load_p1rlv13823_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0ca6e47-afec-4d61-885a-e38176b32444"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c03ecb1d-7a8d-432a-87f1-649a7a2c0bd8"}}}}, {"uuid": "bc9b1700-bb49-4cb1-ba5d-5f80b5313fde", "name": "19de82c2-7a92-46ca-bc78-b9aa550e0efc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1222862909492073, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34523553920221683, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "481ac917-3cd4-4104-bab6-aad3b2b02a90", "name": "1612e353-bc27-4924-95ca-d05df4a50023", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bc9b1700-bb49-4cb1-ba5d-5f80b5313fde"}}}]}, {"uuid": "96ad3f28-9350-4e7f-abbc-430e1bb63746", "name": "load_p1rlv13823_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0ca6e47-afec-4d61-885a-e38176b32444"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "481ac917-3cd4-4104-bab6-aad3b2b02a90"}}}}, {"uuid": "79f3753a-7149-4157-b5e4-68982efaa8ca", "name": "093cd540-9bbc-4ee5-a1e0-2e2ef4a34478_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0669054080609572, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7994840804155045, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f2b10606-cf40-4f5e-bb6b-1183f05e041e", "name": "acb548ef-de03-45bf-bf02-d36ee7faa744", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "79f3753a-7149-4157-b5e4-68982efaa8ca"}}}]}, {"uuid": "9c321716-f7ca-445e-b012-ab6f30c94193", "name": "load_p1rlv15585_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17bf6d8f-8215-4294-b921-cc3e34476f1e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f2b10606-cf40-4f5e-bb6b-1183f05e041e"}}}}, {"uuid": "e0082e7d-626d-4758-b35b-36b85a8bff3c", "name": "35e9eec9-3f85-4855-bfa4-52cf1d9cba4e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0669054080609572, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7994840804155045, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1edba1d9-3282-4395-a1ac-8fd917612c27", "name": "d0a1ea2f-1355-4c4d-878f-841f1e375af0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e0082e7d-626d-4758-b35b-36b85a8bff3c"}}}]}, {"uuid": "1cc5b71c-3d4d-4387-9b29-4375835ef133", "name": "load_p1rlv15585_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17bf6d8f-8215-4294-b921-cc3e34476f1e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1edba1d9-3282-4395-a1ac-8fd917612c27"}}}}, {"uuid": "54f40cb1-f555-4f22-9b86-3ed586a0c349", "name": "c29e80eb-35b5-42ba-9bbe-89cbf4d903da_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5604078463831266, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5882122505209306, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "059e1513-1fe8-44d2-9898-82d08b870b03", "name": "9b67a0dd-e06b-428b-bdf8-4ccfb9e0750b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "54f40cb1-f555-4f22-9b86-3ed586a0c349"}}}]}, {"uuid": "73b6699e-ca8b-43e4-b03e-082e1cc0e819", "name": "load_p1rlv15590_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef2a4478-4644-4bd3-9548-ab1d0be338b5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "059e1513-1fe8-44d2-9898-82d08b870b03"}}}}, {"uuid": "0e336d83-0a40-46ee-b0c8-a82812cf81a4", "name": "43ad8f4c-662d-4fb5-a5f9-a48dbaa271a7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5604078463831266, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5882122505209306, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2461bc70-0a3e-46b4-ad45-4297c1165017", "name": "4bf42159-d677-40ea-8cc5-b5591969ab5d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0e336d83-0a40-46ee-b0c8-a82812cf81a4"}}}]}, {"uuid": "7e04a4d6-9633-4b85-8c34-9d443e029fd6", "name": "load_p1rlv15590_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef2a4478-4644-4bd3-9548-ab1d0be338b5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2461bc70-0a3e-46b4-ad45-4297c1165017"}}}}, {"uuid": "f944fca3-773c-4d7f-8b9c-9c768d5194b2", "name": "9a7d04aa-5710-4fb1-bafb-40d7ed8d7695_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.478593979285423, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7308840963144931, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "17274469-c61a-4e5b-9160-1467f85cf8cf", "name": "931f85c8-2769-4c0e-9348-bb5827062179", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f944fca3-773c-4d7f-8b9c-9c768d5194b2"}}}]}, {"uuid": "a5d49acc-5c50-4480-842c-23e9d28d87bf", "name": "load_p1rlv15591_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c04c9ad1-4277-47de-9cec-9ce86e17b4f1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "17274469-c61a-4e5b-9160-1467f85cf8cf"}}}}, {"uuid": "0a49d7eb-c234-4ada-b568-908ac6cb8e4a", "name": "666b1c83-9b0c-4428-a813-b474316ec8f4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.478593979285423, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7308840963144931, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4148c82d-646b-4921-bc7a-6c5bf7f63ec7", "name": "c7b85c79-340b-4ef3-9ed6-191a807611d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0a49d7eb-c234-4ada-b568-908ac6cb8e4a"}}}]}, {"uuid": "ac304791-72f7-4e03-8c61-3aba5baa1c72", "name": "load_p1rlv15591_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c04c9ad1-4277-47de-9cec-9ce86e17b4f1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4148c82d-646b-4921-bc7a-6c5bf7f63ec7"}}}}, {"uuid": "d31de800-7b5e-4b79-8a91-b2ccf0116ef6", "name": "e1eb7567-068e-4f7f-9e16-f511bd93e9f6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.948793644259809, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2896354077041818, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2975b96e-edfa-4ad7-84f0-03367cdabd07", "name": "5e49d6ea-6260-48be-91dd-179c0bc5b5b4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d31de800-7b5e-4b79-8a91-b2ccf0116ef6"}}}]}, {"uuid": "3a9ac693-9be6-498c-ac0d-72e6efaca5cf", "name": "load_p1rlv15595_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "629e2259-2a59-4b20-b8bf-7b3b2c4a48f9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2975b96e-edfa-4ad7-84f0-03367cdabd07"}}}}, {"uuid": "ee77396d-e109-43f4-9c40-6bf91f21ab36", "name": "261e2ad9-5239-44cc-8678-56fd57346b98_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.948793644259809, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2896354077041818, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eeb2ed11-f664-42aa-9324-d0f09b516145", "name": "b870489c-6cb3-4057-80e7-9cd9924ce7b2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ee77396d-e109-43f4-9c40-6bf91f21ab36"}}}]}, {"uuid": "176c85cb-d0d6-4c48-b671-648e88751c24", "name": "load_p1rlv15595_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "629e2259-2a59-4b20-b8bf-7b3b2c4a48f9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eeb2ed11-f664-42aa-9324-d0f09b516145"}}}}, {"uuid": "a0cb21e7-4b27-494e-bb3c-081400c00bc8", "name": "7667dd6b-9cfc-4f76-a0e9-130988b27064_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6211116916449642, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3778136238343289, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "71b9d2b3-acfd-4691-9f5f-adf773dd27d8", "name": "f26b0db5-6978-4f0a-a69e-fc122b3225bb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a0cb21e7-4b27-494e-bb3c-081400c00bc8"}}}]}, {"uuid": "bf2cc4c4-abae-4bad-9ca5-5ea2c5f8bbfc", "name": "load_p1rlv15598_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "af6b7d1b-896f-44ac-8038-748c74507253"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "71b9d2b3-acfd-4691-9f5f-adf773dd27d8"}}}}, {"uuid": "81dfd6e0-dbbb-41cf-81aa-9fb817150959", "name": "8b6a8b1c-53fd-4091-9649-2bfb2059685f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6211116916449642, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3778136238343289, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10db06a2-89ef-4e34-9cbb-f016a6dc8746", "name": "60ca488e-a6f0-43aa-9158-5c4134a82e18", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "81dfd6e0-dbbb-41cf-81aa-9fb817150959"}}}]}, {"uuid": "ab44ad34-bc95-4072-8e13-b0f8a2f34e93", "name": "load_p1rlv15598_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "af6b7d1b-896f-44ac-8038-748c74507253"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10db06a2-89ef-4e34-9cbb-f016a6dc8746"}}}}, {"uuid": "de0aecc7-b36d-4357-a63e-d9785ef9bd9e", "name": "e8956775-6849-4664-a683-f47391afb338_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6626119076444468, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.30654437548368263, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "be09f5f7-fed8-43b1-b26d-c8aec95e842a", "name": "84b3e339-af7c-41c6-b51d-3c1a69a7ecf2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "de0aecc7-b36d-4357-a63e-d9785ef9bd9e"}}}]}, {"uuid": "62789cd6-098e-4f7b-8814-72c8eb1034f7", "name": "load_p1rlv15599_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ae1bbf1-459f-4346-b525-393b7d1dc958"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "be09f5f7-fed8-43b1-b26d-c8aec95e842a"}}}}, {"uuid": "8f1f6184-fcb4-4f3a-8e3f-f9f39682703d", "name": "a0dec14d-ea6f-4bfe-8b30-760d5443cf0a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6626119076444468, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.30654437548368263, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "01885877-0367-499f-83f1-52c8a24fec2e", "name": "ebec3fea-a57f-42a2-ab97-b2a72764c4a9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8f1f6184-fcb4-4f3a-8e3f-f9f39682703d"}}}]}, {"uuid": "ee2fb437-7c18-43e0-a778-72bbb4ecaf9d", "name": "load_p1rlv15599_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ae1bbf1-459f-4346-b525-393b7d1dc958"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "01885877-0367-499f-83f1-52c8a24fec2e"}}}}, {"uuid": "e56b29a0-5f6f-4023-90d3-cfe2d5ef010b", "name": "168abaa0-2fb2-4799-a684-581c86f41a4f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5348201699646123, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21241824123648728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b5869fd3-257a-473f-b5d2-282d0b26d37c", "name": "40231832-f936-4a1e-8d34-f03562bbd8aa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e56b29a0-5f6f-4023-90d3-cfe2d5ef010b"}}}]}, {"uuid": "5c5f9ae0-221c-48b9-86c2-5f669de204a3", "name": "load_p1rlv15604_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95b45d46-b7e7-46e2-98d9-5034e2fa0a17"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b5869fd3-257a-473f-b5d2-282d0b26d37c"}}}}, {"uuid": "87de1d2f-cb99-4681-b480-a5253cd1986a", "name": "0ee55c44-0e48-4ead-8915-bd8a7ece68c4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5348201699646123, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21241824123648728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "524946ab-d09d-4447-8882-4767d74df004", "name": "a25383b2-0b5e-4385-a110-4074e5c8c5b4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "87de1d2f-cb99-4681-b480-a5253cd1986a"}}}]}, {"uuid": "3fee4c6e-4a64-4574-bd57-4bfcba0420d2", "name": "load_p1rlv15604_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95b45d46-b7e7-46e2-98d9-5034e2fa0a17"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "524946ab-d09d-4447-8882-4767d74df004"}}}}, {"uuid": "662ce46f-3407-471f-a2d1-7adef310daae", "name": "b17569db-16f1-46a4-82ef-66575d501701_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7411160800233395, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1601349573814363, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bfcb1024-72a9-490c-8f55-ccb820aca246", "name": "0d318d79-dcc9-40fd-a6ea-08c8a1ae04be", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "662ce46f-3407-471f-a2d1-7adef310daae"}}}]}, {"uuid": "cb8b01f1-db5f-4676-8d79-e4ccbf10fae9", "name": "load_p1rlv15605_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcbee2ff-bf73-4834-bc3c-46fa0cfcad7c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bfcb1024-72a9-490c-8f55-ccb820aca246"}}}}, {"uuid": "205aab40-1007-48e6-83a7-4510a1f97591", "name": "8175f2e1-ebdb-424a-a3c2-2caf2256e5fc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7411160800233395, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1601349573814363, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1dedfe32-2b65-4f1a-a054-b0de2a8836b9", "name": "1a392444-0d33-46c5-8e8d-cbd0f3964e7c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "205aab40-1007-48e6-83a7-4510a1f97591"}}}]}, {"uuid": "3864a69d-0240-4a2a-83cd-4d7e71841b86", "name": "load_p1rlv15605_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcbee2ff-bf73-4834-bc3c-46fa0cfcad7c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1dedfe32-2b65-4f1a-a054-b0de2a8836b9"}}}}, {"uuid": "828cc09a-fe2a-4ee1-9a72-a9b480f38b6e", "name": "fa3d92fd-97ad-40ff-9d8f-f84c88373f5c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1813646779377422, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20173832232537287, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fc35cab6-95e9-44c5-b70f-05b92b4d412d", "name": "fc0295ec-7b0d-4e55-bd2d-8d88ed0eabb7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "828cc09a-fe2a-4ee1-9a72-a9b480f38b6e"}}}]}, {"uuid": "f3c39724-bce3-49eb-a332-5055b6ee129b", "name": "load_p1rlv15608_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13d6bce6-9066-43a1-b2b6-00a2a4398958"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fc35cab6-95e9-44c5-b70f-05b92b4d412d"}}}}, {"uuid": "c83a74b2-d475-4147-808e-0dccf1a9a3b4", "name": "3d38d38b-5d2d-4970-b5e3-886dde0671c1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1813646779377422, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20173832232537287, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "002ae075-c151-4cc2-9fb9-85a86472f2f9", "name": "a87fb5a0-40b5-4eee-b194-d1f698ed5f37", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c83a74b2-d475-4147-808e-0dccf1a9a3b4"}}}]}, {"uuid": "9055524e-3ac0-4565-b9cd-93f4591fcec6", "name": "load_p1rlv15608_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13d6bce6-9066-43a1-b2b6-00a2a4398958"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "002ae075-c151-4cc2-9fb9-85a86472f2f9"}}}}, {"uuid": "4212ded5-f581-4764-a59d-65fa5f2a198c", "name": "5d907014-cc5a-402a-8bf4-c18f781cafa2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.046232297850773, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7285366000251032, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "46d7587a-7dad-42d6-b692-57ee52c08570", "name": "443cdf73-68ba-4425-9e0d-2be0e1cf4df1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4212ded5-f581-4764-a59d-65fa5f2a198c"}}}]}, {"uuid": "e5249452-bd5d-4408-aa97-f2be5b14b2f0", "name": "load_p1rlv15616_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43ed408e-35e2-4bca-9060-a0c211aea1e7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "46d7587a-7dad-42d6-b692-57ee52c08570"}}}}, {"uuid": "0384f4b8-3dd0-4a01-b3f9-5c3a03a67deb", "name": "82d07e53-05b9-4605-8c73-35c475f1fa40_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.046232297850773, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7285366000251032, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "acb2dbdb-58a4-4de6-9fc8-e8efcb0a1324", "name": "a2877474-25d5-4c42-a694-63c46491a769", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0384f4b8-3dd0-4a01-b3f9-5c3a03a67deb"}}}]}, {"uuid": "a44343d7-5bcb-4693-96f3-3ad2aa61a044", "name": "load_p1rlv15616_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43ed408e-35e2-4bca-9060-a0c211aea1e7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "acb2dbdb-58a4-4de6-9fc8-e8efcb0a1324"}}}}, {"uuid": "eabfde0e-54b8-44df-bd7e-aea1271f9ace", "name": "0f43caab-2a22-4b0f-8055-033e5a86d4da_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2795803428770153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1698974287191981, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f9eb67dd-74bc-4c46-831e-e02d1fb1d898", "name": "88e50214-eb50-4621-b000-3d73ab001257", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eabfde0e-54b8-44df-bd7e-aea1271f9ace"}}}]}, {"uuid": "dea108c1-e877-4a90-8f38-feaf33fb1e3b", "name": "load_p1rlv15618_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "200aa7d8-0a43-4086-b0e7-f63cae75671d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f9eb67dd-74bc-4c46-831e-e02d1fb1d898"}}}}, {"uuid": "72e1553d-91d7-47c0-a4eb-4e5b1bb3bed1", "name": "80570795-9843-475c-9431-752d767622cc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2795803428770153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1698974287191981, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9519faae-cb8f-4544-8ea7-cb5f9a681c54", "name": "d14c1fab-bf8a-42c8-8b83-33d7dd168bf8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72e1553d-91d7-47c0-a4eb-4e5b1bb3bed1"}}}]}, {"uuid": "9e1f6c2e-94d7-4757-b33b-82228d4eabd2", "name": "load_p1rlv15618_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "200aa7d8-0a43-4086-b0e7-f63cae75671d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9519faae-cb8f-4544-8ea7-cb5f9a681c54"}}}}, {"uuid": "b092f45d-9015-4c29-a4a7-b76faa9b58f0", "name": "9c39cbd7-0fe5-4467-a773-210bfae39bd0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8454259827639654, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5306926284494342, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "065a8765-34d9-4f06-9611-d4f0c1216795", "name": "a23ad787-c2d5-496e-925e-33372bfc20a6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b092f45d-9015-4c29-a4a7-b76faa9b58f0"}}}]}, {"uuid": "f762ccda-562f-486a-9c52-40097d41b4da", "name": "load_p1rlv15619_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905a4857-5d3d-4e51-9ab0-70d634170f92"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "065a8765-34d9-4f06-9611-d4f0c1216795"}}}}, {"uuid": "e4498d19-aa92-4345-a2ac-ff62048aeb4c", "name": "fbbad8a2-7d6a-4e4d-b380-17af10ae674a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8454259827639654, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5306926284494342, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d223123b-5936-4b5f-8033-2e9c6b2c90fb", "name": "3dc826b0-e993-46b2-acdb-f78e8576f816", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e4498d19-aa92-4345-a2ac-ff62048aeb4c"}}}]}, {"uuid": "d30393bc-6418-416e-83ac-29f25e4da89f", "name": "load_p1rlv15619_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905a4857-5d3d-4e51-9ab0-70d634170f92"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d223123b-5936-4b5f-8033-2e9c6b2c90fb"}}}}, {"uuid": "3ea87847-071d-451f-bd19-6d82c1ce111f", "name": "aa9ec67c-7807-4a16-acdf-62bc65f7fa19_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5924067901709626, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.46681640832512994, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "08427ead-ad00-4a10-a10d-e7d4da17a254", "name": "a2e361e0-b106-43a0-906c-35a429e96aea", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3ea87847-071d-451f-bd19-6d82c1ce111f"}}}]}, {"uuid": "1904ede3-a1c8-4565-adc7-d679845b0c95", "name": "load_p1rlv15623_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13f790a1-18c0-498f-8525-fbaf0350947b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "08427ead-ad00-4a10-a10d-e7d4da17a254"}}}}, {"uuid": "4f3fa56d-4b8b-47bc-8a88-d4518112bfbb", "name": "49271121-f195-4dc2-9617-3e41417e9f63_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5924067901709626, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.46681640832512994, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ddfbadbd-d94a-463c-b3fa-a1586a9f8ff3", "name": "e9f05cd5-7af3-4225-81e8-0d9267e8fa64", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4f3fa56d-4b8b-47bc-8a88-d4518112bfbb"}}}]}, {"uuid": "95a7b4d1-8c53-42fd-8fe4-74537a2ee45a", "name": "load_p1rlv15623_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13f790a1-18c0-498f-8525-fbaf0350947b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ddfbadbd-d94a-463c-b3fa-a1586a9f8ff3"}}}}, {"uuid": "1d62a7aa-8b10-44bd-ace9-bf5f8061dd23", "name": "f3ee2678-10a3-407d-a28b-1259924b2b44_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6658189308849048, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3864031015392916, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ee3e309b-bd35-40cd-b2b0-6498a1ff6210", "name": "df422b58-6f34-4522-86e9-cd47c632de13", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1d62a7aa-8b10-44bd-ace9-bf5f8061dd23"}}}]}, {"uuid": "fa99cc7b-2e73-4524-b411-78eacbc75990", "name": "load_p1rlv15625_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb08eda2-b277-4bfd-9ea0-9c36765400bd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ee3e309b-bd35-40cd-b2b0-6498a1ff6210"}}}}, {"uuid": "2a5215a6-8da4-4afa-a0b7-3cef1822b4ef", "name": "8877d052-007c-40eb-a879-4f58aa9e7211_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6658189308849048, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3864031015392916, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b6bfe314-6117-4811-b014-92996f13c84f", "name": "6fa26fb9-a44a-4269-84ab-a6b6259ca31f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2a5215a6-8da4-4afa-a0b7-3cef1822b4ef"}}}]}, {"uuid": "87950dc1-c23f-454f-845e-94f5fbb13603", "name": "load_p1rlv15625_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb08eda2-b277-4bfd-9ea0-9c36765400bd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b6bfe314-6117-4811-b014-92996f13c84f"}}}}, {"uuid": "be3ca802-c7d2-47de-972d-322cd93807e5", "name": "a17e6c75-25ef-446e-861a-3263eef75cc6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3315344999322854, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13574204648198762, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "93b4ac9f-fd66-4459-b9b2-a60a7625fdd6", "name": "1b46f718-4f26-4402-a080-7744de60b05b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "be3ca802-c7d2-47de-972d-322cd93807e5"}}}]}, {"uuid": "ad0a8ed6-24d4-4e8f-ac53-88c9b689021e", "name": "load_p1rlv15632_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ccbef4c-6bf7-4892-a3b9-b51aca495137"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "93b4ac9f-fd66-4459-b9b2-a60a7625fdd6"}}}}, {"uuid": "c810fca3-d772-4a8f-9082-c6e72ac4e6db", "name": "6d0f8720-ca97-4483-85b1-fcfbc3d9a247_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3315344999322854, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13574204648198762, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eb7dc31a-acec-41e8-9d07-1c90bf9490b1", "name": "d7af0015-c346-4b4e-a53e-6fa094559f64", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c810fca3-d772-4a8f-9082-c6e72ac4e6db"}}}]}, {"uuid": "b326beb8-6531-4490-84c5-a9014d18cd2f", "name": "load_p1rlv15632_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ccbef4c-6bf7-4892-a3b9-b51aca495137"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eb7dc31a-acec-41e8-9d07-1c90bf9490b1"}}}}, {"uuid": "9e89186f-82c8-41ae-9f16-c28e00c70659", "name": "d62a87d2-b3fd-4ff1-a057-d63355bf6822_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4063851199490187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16385595528128288, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bbc4101b-7e69-4f71-ae4f-53856d686d1e", "name": "2c8f31ec-0268-4a3f-801f-a40f82c15c62", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9e89186f-82c8-41ae-9f16-c28e00c70659"}}}]}, {"uuid": "375a5e05-3568-4779-b978-37d6522d61fb", "name": "load_p1rlv15633_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce7b60c8-43ee-441d-9f18-5b2722dcc0a7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bbc4101b-7e69-4f71-ae4f-53856d686d1e"}}}}, {"uuid": "9f5b58b3-7848-4775-845e-a70f87019061", "name": "35b90394-c4d5-42e8-b3ed-6a734fc56860_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4063851199490187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16385595528128288, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f85b18e2-a935-4f00-bcc3-eb8850675b5f", "name": "d22eb452-a604-4f20-9803-82933df8d181", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9f5b58b3-7848-4775-845e-a70f87019061"}}}]}, {"uuid": "fd01f3fc-80cc-451d-ba6b-6cdba33c7311", "name": "load_p1rlv15633_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce7b60c8-43ee-441d-9f18-5b2722dcc0a7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f85b18e2-a935-4f00-bcc3-eb8850675b5f"}}}}, {"uuid": "2300e2b1-e466-437d-af39-12dc106ea0f1", "name": "7083a3fa-3140-4ecb-8a87-8c51ca8cac19_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.416529851525178, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1922168413006689, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7b14e0f6-ca0f-4794-8615-bd6fd05cc72d", "name": "ec7fc012-219d-49fd-a2f2-21417ffd3ed0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2300e2b1-e466-437d-af39-12dc106ea0f1"}}}]}, {"uuid": "cc963929-deac-4c2d-93ca-eec6f3895b48", "name": "load_p1rlv15640_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83c2de51-1b04-483c-8ce7-14b9e5e027b9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7b14e0f6-ca0f-4794-8615-bd6fd05cc72d"}}}}, {"uuid": "c18fc0b9-d5ea-4253-b272-6a950aa0a4a2", "name": "20882bd3-8746-4413-a346-e24319680df6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.416529851525178, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1922168413006689, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "73414de7-7f37-44cd-a4ca-74716bb26fa2", "name": "106eb0d3-138e-4640-8725-abd2ec7b195f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c18fc0b9-d5ea-4253-b272-6a950aa0a4a2"}}}]}, {"uuid": "8de61cc1-a633-4ef4-ad8d-12c1c479f199", "name": "load_p1rlv15640_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83c2de51-1b04-483c-8ce7-14b9e5e027b9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "73414de7-7f37-44cd-a4ca-74716bb26fa2"}}}}, {"uuid": "27831177-8035-4f9b-b8ff-9d9ea31439af", "name": "69f11f40-bb60-4012-8526-4aad1d2aa1ab_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7538406343539102, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42176934505781605, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4e2d6287-dbf6-47f8-b6f0-bf31d11f7660", "name": "9556de5c-ea12-4b65-ba76-b3e4676b8b38", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "27831177-8035-4f9b-b8ff-9d9ea31439af"}}}]}, {"uuid": "0b6ca4e4-706a-4f46-abf0-c6bc68a0ddac", "name": "load_p1rlv15641_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4363602a-eb9c-41b8-8130-7bb839f4eb5a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4e2d6287-dbf6-47f8-b6f0-bf31d11f7660"}}}}, {"uuid": "873fe6a2-2e17-4658-b8f6-1a976d9d758f", "name": "8823a533-2fa9-4c9d-b797-0df5529291c2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7538406343539102, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42176934505781605, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "de902fe0-2d32-42b3-a757-0dba337785ad", "name": "89d360e4-e1c1-43c5-bad9-2f3f7ea7c261", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "873fe6a2-2e17-4658-b8f6-1a976d9d758f"}}}]}, {"uuid": "434acaad-5c0d-49d4-a568-2850f9fd6300", "name": "load_p1rlv15641_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4363602a-eb9c-41b8-8130-7bb839f4eb5a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "de902fe0-2d32-42b3-a757-0dba337785ad"}}}}, {"uuid": "b5d548f7-c235-4f56-a5e8-73b437dfec64", "name": "2dcf3af2-8b6d-4f62-ace6-d8e121983252_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.735884899619907, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7862059386133167, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ea218f6e-dfd3-438b-adcf-852aa343204b", "name": "28b3c749-4582-4f26-9e07-d9887cd70465", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5d548f7-c235-4f56-a5e8-73b437dfec64"}}}]}, {"uuid": "31e35185-7faa-4548-a082-94b778d715eb", "name": "load_p1rlv16450_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5f1e7aa-d93a-4164-8bc0-f920259304a8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ea218f6e-dfd3-438b-adcf-852aa343204b"}}}}, {"uuid": "92762c3b-686c-4ce0-9e31-45def15ff6d2", "name": "82753a5d-5757-46fd-b47b-63058b1199e2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.735884899619907, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7862059386133167, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5a3f23f0-a34b-4071-93c5-5d8151415cd1", "name": "8e27ec17-be51-429a-8af7-638943f57ef9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "92762c3b-686c-4ce0-9e31-45def15ff6d2"}}}]}, {"uuid": "6dd3a333-b113-4ad1-9cfc-2ee8193aa02c", "name": "load_p1rlv16450_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5f1e7aa-d93a-4164-8bc0-f920259304a8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5a3f23f0-a34b-4071-93c5-5d8151415cd1"}}}}, {"uuid": "d18f355d-432d-4a81-9f79-60ce72b17264", "name": "cb98fa40-de8c-4a97-bb6c-3b878a09ab9c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5229589832640044, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3359880712066463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7ce996db-a06e-43c8-b644-32f3f75d9413", "name": "8e4e1985-8cc9-45fc-8143-fc433d8de810", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d18f355d-432d-4a81-9f79-60ce72b17264"}}}]}, {"uuid": "9fb0240a-337c-448b-9787-66aea3750bf3", "name": "load_p1rlv16463_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9c505d7-3fb9-4eb5-89c6-c9c8da32fd05"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7ce996db-a06e-43c8-b644-32f3f75d9413"}}}}, {"uuid": "3e585105-6eb1-4266-852c-d96bef3e20ae", "name": "9ac799f5-91b0-4380-a5f3-e07f877df701_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5229589832640044, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3359880712066463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8c691fc0-826c-469b-8458-924b9d4bb2a5", "name": "8bbcadb3-5213-4a50-8ee5-177fdb53534a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3e585105-6eb1-4266-852c-d96bef3e20ae"}}}]}, {"uuid": "22237d0f-60d8-42bf-a53a-99468f18ea7d", "name": "load_p1rlv16463_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9c505d7-3fb9-4eb5-89c6-c9c8da32fd05"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8c691fc0-826c-469b-8458-924b9d4bb2a5"}}}}, {"uuid": "72f9e304-6f77-4048-b244-b47d987386d5", "name": "4354d6de-b840-4a59-921c-48546a5918ba_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.868352089343376, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.8531787232937273, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "93240c18-7579-465b-b310-1d14ad8e8dd2", "name": "1b380adb-20db-4447-a4b5-36eb7224e1cd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72f9e304-6f77-4048-b244-b47d987386d5"}}}]}, {"uuid": "abdb5a0e-b49e-4045-8a50-c71f708e8057", "name": "load_p1rlv16475_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d400b1b2-8404-4b80-b110-6f96e000314f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "93240c18-7579-465b-b310-1d14ad8e8dd2"}}}}, {"uuid": "888d1efa-55da-4fa0-8fdb-34cd43bddd9c", "name": "a7c7a516-35b1-4b3f-879d-b052684964fa_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.868352089343376, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.8531787232937273, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "de871ffd-f009-4ca8-a997-be1e4f88ae66", "name": "28e02cf2-5047-48fa-b542-ae2aa753401c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "888d1efa-55da-4fa0-8fdb-34cd43bddd9c"}}}]}, {"uuid": "7022f268-f6f5-4642-84f1-7377872a39a4", "name": "load_p1rlv16475_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d400b1b2-8404-4b80-b110-6f96e000314f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "de871ffd-f009-4ca8-a997-be1e4f88ae66"}}}}, {"uuid": "e54ec48a-9076-420f-9ddf-0ab004897c81", "name": "ad316ba8-bdcf-4aee-9cab-506969847b73_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8816313976351899, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.38647586315113985, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b570d166-7b24-49d5-88c7-3c2de440b7aa", "name": "46e26fb5-cd03-4009-bee3-b4653939f1ce", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e54ec48a-9076-420f-9ddf-0ab004897c81"}}}]}, {"uuid": "8dc71af4-8b75-4782-aebf-fbdb147c277f", "name": "load_p1rlv16483_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa6db7ee-126d-4aa9-9733-35ff1c1d5992"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b570d166-7b24-49d5-88c7-3c2de440b7aa"}}}}, {"uuid": "7c2bbc90-c373-4787-802b-91686bbd16d5", "name": "090e10fe-03aa-46ba-94f3-4af619297bc0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8816313976351899, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.38647586315113985, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "74fecb5e-7b8c-4aad-8bf6-f551ad043802", "name": "e5f549bd-698c-4aeb-a297-e7da4d5ac566", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7c2bbc90-c373-4787-802b-91686bbd16d5"}}}]}, {"uuid": "4efd8407-afeb-45a9-a658-989c9fd49d4c", "name": "load_p1rlv16483_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa6db7ee-126d-4aa9-9733-35ff1c1d5992"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "74fecb5e-7b8c-4aad-8bf6-f551ad043802"}}}}, {"uuid": "6a389484-bc0c-4d4a-9d31-54a1bac5a030", "name": "517e95b3-d4e7-426f-a862-33d7532e6650_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8285317723273034, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9836303634928509, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50c5124f-e767-48e1-8fa3-c1f23dc1d946", "name": "a0ff77a5-a9f2-47c3-a9f0-0e6549119ed2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6a389484-bc0c-4d4a-9d31-54a1bac5a030"}}}]}, {"uuid": "f0aac045-0e01-4455-a8d7-50f8a24b39c3", "name": "load_p1rlv16507_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27afe70a-9123-4b0c-9f50-b5355aafcf7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50c5124f-e767-48e1-8fa3-c1f23dc1d946"}}}}, {"uuid": "c1f72a93-2c6d-40f0-9e88-066edd0bc299", "name": "2473520e-3c51-4226-8681-2bf2d8f864ed_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8285317723273034, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9836303634928509, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "46e400db-45a5-4016-81f6-e5e8c50fe0cf", "name": "ae99d7bd-fb17-4727-8fa6-b70d61ae23d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c1f72a93-2c6d-40f0-9e88-066edd0bc299"}}}]}, {"uuid": "f9802863-0ac4-4648-9bc4-1868376b0046", "name": "load_p1rlv16507_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27afe70a-9123-4b0c-9f50-b5355aafcf7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "46e400db-45a5-4016-81f6-e5e8c50fe0cf"}}}}, {"uuid": "f3ad0ef9-ac5b-424c-8d55-c35e3ec43d71", "name": "5d16bf4b-825c-48d8-a9f2-9591f938775a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6976007564693765, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0012223642000246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ffe7b4e6-144c-462e-b003-deb4036a99ea", "name": "3d434c4a-07a6-4e66-ac93-41189685d682", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f3ad0ef9-ac5b-424c-8d55-c35e3ec43d71"}}}]}, {"uuid": "fd615f28-bdaf-4b10-9f8b-29ce22898ce0", "name": "load_p1rlv16530_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0333a34b-4027-4d9a-9d4a-f867c8a317bc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ffe7b4e6-144c-462e-b003-deb4036a99ea"}}}}, {"uuid": "00566696-d4c5-4a31-a3ea-5c779c66ed5f", "name": "a348b52e-9808-4ede-8bdb-17768e1e41f4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6976007564693765, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0012223642000246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c715d386-cc2d-42e8-89f5-4da411227d56", "name": "e6ec601a-04c7-431c-883b-c60ba0d73b21", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "00566696-d4c5-4a31-a3ea-5c779c66ed5f"}}}]}, {"uuid": "5b4755a8-7f30-4e67-99cc-615124fa8969", "name": "load_p1rlv16530_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0333a34b-4027-4d9a-9d4a-f867c8a317bc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c715d386-cc2d-42e8-89f5-4da411227d56"}}}}, {"uuid": "7c3feb6e-7699-4b8b-bf81-a1303d4ac613", "name": "b00d351f-caff-4efb-8285-802db0138ef5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4622944887503224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10483650830237357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4aae7ad0-4668-4e2e-b349-05395e064136", "name": "c6792b81-42b7-4e82-b405-1329e781b3c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7c3feb6e-7699-4b8b-bf81-a1303d4ac613"}}}]}, {"uuid": "a6fd724d-b412-4387-baec-28ba0a8ae5c1", "name": "load_p1rlv16541_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f7be042-6681-4694-872d-a1cb701016c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4aae7ad0-4668-4e2e-b349-05395e064136"}}}}, {"uuid": "d789f394-4e99-4645-94a6-dd32d419c082", "name": "b66e098d-d15f-4275-b427-18e96faa709b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4622944887503224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10483650830237357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6377f5e3-4e07-4044-bdd0-6e24cf13cf0b", "name": "1276e012-d2e9-4117-a1a2-3d977832a75a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d789f394-4e99-4645-94a6-dd32d419c082"}}}]}, {"uuid": "87a3f4ec-41e0-4b20-ab89-7fb590e660c7", "name": "load_p1rlv16541_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f7be042-6681-4694-872d-a1cb701016c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6377f5e3-4e07-4044-bdd0-6e24cf13cf0b"}}}}, {"uuid": "6c69e703-71cd-486d-ad05-17837f07fddc", "name": "2ced9ebc-d211-443f-9e72-af7d95d3849a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.962510599658346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.39927803268124257, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3e01c7b8-27b5-4ec3-8f06-3389efbecb65", "name": "9af5c881-7e46-4b5e-a998-959c23794c2e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c69e703-71cd-486d-ad05-17837f07fddc"}}}]}, {"uuid": "94d30e7c-66e1-41e1-9fd0-101444495776", "name": "load_p1rlv16573_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90d9dbe9-f9c9-4a4e-8ada-cb459778687b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3e01c7b8-27b5-4ec3-8f06-3389efbecb65"}}}}, {"uuid": "676745fc-79d7-458c-9e05-6e092caa2b3f", "name": "1a1a8e15-1ec4-4929-97f2-cc5316e1bc83_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.962510599658346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.39927803268124257, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0e2c3022-4cb6-446b-ae2c-3428b4af05af", "name": "336a777f-09ce-4bf3-b11a-3cbe06f7619d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "676745fc-79d7-458c-9e05-6e092caa2b3f"}}}]}, {"uuid": "1b19dde5-8cdf-4897-a926-2c48ebc763a9", "name": "load_p1rlv16573_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90d9dbe9-f9c9-4a4e-8ada-cb459778687b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0e2c3022-4cb6-446b-ae2c-3428b4af05af"}}}}, {"uuid": "17418aba-721c-4315-94ab-f8def94d1c19", "name": "fce4c617-6785-4a22-b6a1-ff8dec801232_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6976007564693765, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0012223642000246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ddd490af-260d-46e4-8ca9-b21cc6bc2d46", "name": "f35dc42e-9781-4443-84df-4a624454cc9f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "17418aba-721c-4315-94ab-f8def94d1c19"}}}]}, {"uuid": "397456e3-3cb5-470b-be37-3e79d3c899ed", "name": "load_p1rlv16584_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "344c6b21-94c9-4912-a19e-69fbae5eed27"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ddd490af-260d-46e4-8ca9-b21cc6bc2d46"}}}}, {"uuid": "f6211fd3-d0ef-414f-8de3-78c78457a87b", "name": "6aa9bc57-2165-459d-b3a6-36c43fcac88b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6976007564693765, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0012223642000246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2a865d4a-7f45-47ee-92b3-1f9e5a08b46e", "name": "81959ead-a5ed-4ab3-b74d-0ab0b5855cbe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f6211fd3-d0ef-414f-8de3-78c78457a87b"}}}]}, {"uuid": "b535f7e2-9aa2-4481-8507-d774c5c8dd99", "name": "load_p1rlv16584_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "344c6b21-94c9-4912-a19e-69fbae5eed27"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2a865d4a-7f45-47ee-92b3-1f9e5a08b46e"}}}}, {"uuid": "7648cf74-49da-4631-b023-8a26cdff5a97", "name": "db32424a-4750-4cf6-8cb1-bca90476f529_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4820522770729507, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1125677048872814, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "80554816-b458-45b0-8147-a0037851a770", "name": "7166e439-29ab-4ca8-97ad-b062ea3cdbf4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7648cf74-49da-4631-b023-8a26cdff5a97"}}}]}, {"uuid": "4e358a7e-2f97-47f3-b250-04a30db6372c", "name": "load_p1rlv16604_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f9ecb3f-8b64-4598-a9d1-d794c6800d33"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "80554816-b458-45b0-8147-a0037851a770"}}}}, {"uuid": "d64daa14-f7d7-453a-b0a2-b461372c8200", "name": "8a74909b-00b5-4d43-a62c-e396702c1c31_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4820522770729507, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1125677048872814, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "888cb114-7f8f-4d27-b18c-9a8bdf45a92e", "name": "2ac3ef4a-cebc-4d3c-a28c-3690ee0ba266", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d64daa14-f7d7-453a-b0a2-b461372c8200"}}}]}, {"uuid": "e0a235d2-9c25-45cd-a2c3-f08de8da1c81", "name": "load_p1rlv16604_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f9ecb3f-8b64-4598-a9d1-d794c6800d33"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "888cb114-7f8f-4d27-b18c-9a8bdf45a92e"}}}}, {"uuid": "6b32ecbb-ef6d-492e-8dcb-52e75307d744", "name": "ad0f3347-eb7f-4599-800f-4b0b8801488a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8791002615066037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24190904367644575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "050f8a43-86e9-440e-9013-a602a5347d35", "name": "a22947a6-bcbc-4935-aba8-86f0843db3d7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6b32ecbb-ef6d-492e-8dcb-52e75307d744"}}}]}, {"uuid": "c35648e4-98a8-4b53-93f4-c9832c9a4772", "name": "load_p1rlv17239_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba567aae-a893-41d3-8fd1-8357d3cab35d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "050f8a43-86e9-440e-9013-a602a5347d35"}}}}, {"uuid": "145622c3-10b0-43f9-b6eb-5fba18da4dc7", "name": "cbe728db-d030-4a08-a9ae-2f266c38827d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8791002615066037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24190904367644575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2d231892-6703-4130-9edf-3084ca95ef2d", "name": "4ea83401-f40a-499f-bbf0-b3f2158897dc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "145622c3-10b0-43f9-b6eb-5fba18da4dc7"}}}]}, {"uuid": "fa50fe3e-5e73-434b-8f50-8a2a6a1d4b63", "name": "load_p1rlv17239_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba567aae-a893-41d3-8fd1-8357d3cab35d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2d231892-6703-4130-9edf-3084ca95ef2d"}}}}, {"uuid": "fcd97511-4190-4064-a54f-9874215e5e8f", "name": "59d5dc07-dbbc-48cc-bfdc-ea9b13fbbd10_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.664483224984605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9538644530515166, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e271eab7-9cd8-42f1-b8c0-0c11acf307d8", "name": "52fd7431-2ac2-402d-ac11-d8f5d4afe61b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fcd97511-4190-4064-a54f-9874215e5e8f"}}}]}, {"uuid": "d2090903-e858-43d0-bed5-eacf872228dd", "name": "load_p1rlv17246_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acfdbe95-2d82-463a-9d1f-6fd2688adf16"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e271eab7-9cd8-42f1-b8c0-0c11acf307d8"}}}}, {"uuid": "1e737e3c-83b0-4326-bf8f-b6acae50638d", "name": "9ee4961e-7303-4ff5-834c-32b092f8dde4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.664483224984605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9538644530515166, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d2309fed-4bd6-4ec1-a07c-9776f9d23797", "name": "d8a40c85-27ed-4609-81cb-53106e525a8b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1e737e3c-83b0-4326-bf8f-b6acae50638d"}}}]}, {"uuid": "6deb03f4-71f9-4740-b29a-428e44a88afa", "name": "load_p1rlv17246_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acfdbe95-2d82-463a-9d1f-6fd2688adf16"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d2309fed-4bd6-4ec1-a07c-9776f9d23797"}}}}, {"uuid": "5b8bf031-4224-4dba-9afb-32fd4c970315", "name": "131b04d8-6670-4981-b729-cd45182c9312_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7073298240395912, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.27247283022117846, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ecdec3fa-0fe5-4adc-94e0-b2686c04e60d", "name": "2f40d2d5-37f0-45ff-bdf2-74489ec2cbf1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b8bf031-4224-4dba-9afb-32fd4c970315"}}}]}, {"uuid": "2a0175b3-9542-4c41-845a-5ef0855a6df3", "name": "load_p1rlv17280_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac80cbea-e10a-491a-ba36-06e9fcf74217"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ecdec3fa-0fe5-4adc-94e0-b2686c04e60d"}}}}, {"uuid": "d9fa4f4e-b7d1-4935-8353-239744c09582", "name": "88ca2756-2a7b-46ec-a7bb-074c65e03a8f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7073298240395912, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.27247283022117846, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9a872ec0-9bac-4b01-9536-7be722032b24", "name": "ad7fd0b0-d4bf-4805-9b76-018d3d997a28", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d9fa4f4e-b7d1-4935-8353-239744c09582"}}}]}, {"uuid": "711295f8-9158-44a8-8b6f-5f1498447996", "name": "load_p1rlv17280_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac80cbea-e10a-491a-ba36-06e9fcf74217"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9a872ec0-9bac-4b01-9536-7be722032b24"}}}}, {"uuid": "67a9a2c0-4038-4037-a2e9-7ff562687f15", "name": "23c1537f-8d8f-42ec-8c6b-6d3010087c0a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7675749799903273, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6204429178040327, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f8fc3ba-b7a7-436a-8419-5672be6c1c6a", "name": "a2d63641-53a1-4222-9271-95b4e71989a1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "67a9a2c0-4038-4037-a2e9-7ff562687f15"}}}]}, {"uuid": "b0ea80f7-43ec-44ce-afb5-79f392497f53", "name": "load_p1rlv17291_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04388b89-16fc-40b3-a060-5bc52032874e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f8fc3ba-b7a7-436a-8419-5672be6c1c6a"}}}}, {"uuid": "6676d674-277d-4c80-8d60-99a5c2e5f3c4", "name": "e6c387a3-ca6b-4306-accd-7e17124f02ae_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7675749799903273, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6204429178040327, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "292dc273-0cd2-4e35-aa1c-0c07bfb32add", "name": "0fd2deb4-9d5f-4a37-8208-13600ea0174d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6676d674-277d-4c80-8d60-99a5c2e5f3c4"}}}]}, {"uuid": "8b720fc4-a00e-41f8-9c68-51dc8f90af7f", "name": "load_p1rlv17291_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04388b89-16fc-40b3-a060-5bc52032874e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "292dc273-0cd2-4e35-aa1c-0c07bfb32add"}}}}, {"uuid": "10e86e9d-ca57-4db7-90d5-16cae37b75ba", "name": "80cbee2f-3ab1-4e74-937c-8f4e543a84e4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8744605841296944, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5892496700768608, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "256c9e8a-d0d8-4d4f-b53b-36e6005cab1b", "name": "30d361c3-0aab-4780-8248-faffdfce3d12", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "10e86e9d-ca57-4db7-90d5-16cae37b75ba"}}}]}, {"uuid": "ddea90dc-2e99-4402-91a1-84c31229f44e", "name": "load_p1rlv17303_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04eb7e32-e372-4cb0-94a7-ee418f400bda"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "256c9e8a-d0d8-4d4f-b53b-36e6005cab1b"}}}}, {"uuid": "2069dad0-4b69-4bcb-8fbf-3000584dfdbc", "name": "252eef92-b83b-4753-a651-aa2df01fb01c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8744605841296944, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5892496700768608, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4205920b-6ffd-4d2e-9965-9c548b00f7ca", "name": "29b34c55-66ec-4ca0-8156-33a3be3c9160", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2069dad0-4b69-4bcb-8fbf-3000584dfdbc"}}}]}, {"uuid": "5a0db9b8-a303-4e8f-8ce6-48034af5b2ce", "name": "load_p1rlv17303_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04eb7e32-e372-4cb0-94a7-ee418f400bda"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4205920b-6ffd-4d2e-9965-9c548b00f7ca"}}}}, {"uuid": "39fd1708-e184-4b5d-9036-627aa4903a72", "name": "f2a8f814-c6b3-47c8-b5d0-91d7bc1c9606_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.446531565278448, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9314679219387375, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2166fe2c-b301-44e5-a91b-374f6818f1b4", "name": "74c3edab-08c0-42f4-9445-44987245fb8f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "39fd1708-e184-4b5d-9036-627aa4903a72"}}}]}, {"uuid": "116e8dc6-181a-4c69-85f1-d6db4517f88d", "name": "load_p1rlv17311_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84ebd9bb-dc50-483d-a3c6-044682d4020c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2166fe2c-b301-44e5-a91b-374f6818f1b4"}}}}, {"uuid": "d45d4101-f6dd-4c03-8d23-4e324061add4", "name": "f28f4b69-0589-4998-834b-45744772adcb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.446531565278448, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9314679219387375, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a4efd325-ab67-4330-8d7d-a62e6aec7d3e", "name": "183af1aa-33b5-47d7-895a-7bab90843791", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d45d4101-f6dd-4c03-8d23-4e324061add4"}}}]}, {"uuid": "b50f50bb-1c6e-428f-87db-f970d8bd0257", "name": "load_p1rlv17311_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84ebd9bb-dc50-483d-a3c6-044682d4020c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a4efd325-ab67-4330-8d7d-a62e6aec7d3e"}}}}, {"uuid": "3b56692e-8300-4a54-b121-6b2f3e460062", "name": "6110bf2f-bfca-4a3b-9a92-e766fd8b17b9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.1528026683641635, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1483162213006746, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "025f9caf-f565-4cfd-afee-aee4bbdd1814", "name": "ed801105-f860-41fb-b2cb-97abb0aba42d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3b56692e-8300-4a54-b121-6b2f3e460062"}}}]}, {"uuid": "dc660c7e-6795-4d0c-b2d2-a293b5ad6c20", "name": "load_p1rlv17345_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ead5953-70f2-4db2-ba4d-d203c91d85c1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "025f9caf-f565-4cfd-afee-aee4bbdd1814"}}}}, {"uuid": "e3547a41-5cc3-4d5a-b8c1-443e4d8458eb", "name": "2c56459d-f1c9-4ea4-a11a-6145c16e5d9c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.1528026683641635, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1483162213006746, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "66a2f399-d485-4762-85b5-8a8609023535", "name": "396cda2b-d69c-48ed-a339-5569d54a14c4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e3547a41-5cc3-4d5a-b8c1-443e4d8458eb"}}}]}, {"uuid": "c7c05374-7e21-4d77-91d3-ef29d9ff446d", "name": "load_p1rlv17345_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ead5953-70f2-4db2-ba4d-d203c91d85c1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "66a2f399-d485-4762-85b5-8a8609023535"}}}}, {"uuid": "54c6339c-d9dd-4aee-9394-c9e0b47a0ad4", "name": "2142fbb6-48f3-4fa5-96e6-6078c0281251_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5261964028176471, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5335215898246958, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "38a6dfe5-5a67-41af-8cdb-f85c2ed8074f", "name": "3abae5ba-902f-489b-ac67-d322cfc39009", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "54c6339c-d9dd-4aee-9394-c9e0b47a0ad4"}}}]}, {"uuid": "ef1c7d14-31c7-428c-9e7f-77573cc919e4", "name": "load_p1rlv17347_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d98640c6-d8aa-44e4-9ecf-5998152d3f7d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "38a6dfe5-5a67-41af-8cdb-f85c2ed8074f"}}}}, {"uuid": "d8bdd3b2-05e8-4baa-989c-71c97851d72a", "name": "478c6353-119e-4c78-99f0-8843ffd338db_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5261964028176471, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5335215898246958, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "383e8d73-e53c-4d55-8738-c313c36771e2", "name": "17dae6e6-7c19-4bae-b2cf-b0cc703ca8d4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d8bdd3b2-05e8-4baa-989c-71c97851d72a"}}}]}, {"uuid": "e63b5a6b-93d0-430a-8209-4d24137aebea", "name": "load_p1rlv17347_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d98640c6-d8aa-44e4-9ecf-5998152d3f7d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "383e8d73-e53c-4d55-8738-c313c36771e2"}}}}, {"uuid": "ae5cf2b9-af7a-496d-94ee-9bf57047dee6", "name": "e5e8940f-84fa-4ec3-8975-714342c23e01_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1461342593009323, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5165512162199262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6fab1a1c-4a75-4dd4-930a-b92164297677", "name": "a37d4c59-cf96-4e28-b72c-4b0f54142d95", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ae5cf2b9-af7a-496d-94ee-9bf57047dee6"}}}]}, {"uuid": "0db124db-f2cf-452e-af15-005da2d72994", "name": "load_p1rlv17351_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2695decb-d268-46b2-8604-9c33dc90518b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6fab1a1c-4a75-4dd4-930a-b92164297677"}}}}, {"uuid": "72d51562-9cfa-4874-ab5b-1a14664df786", "name": "4c5373c5-b67d-4963-ad2a-c14c49a86058_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1461342593009323, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5165512162199262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "864ed71a-eb04-45e5-b8fa-07574a13b6e3", "name": "73a98dfa-1d29-4054-a6e4-d627fa9e4407", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72d51562-9cfa-4874-ab5b-1a14664df786"}}}]}, {"uuid": "2cb117f5-e198-4644-b51e-fea0f165b412", "name": "load_p1rlv17351_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2695decb-d268-46b2-8604-9c33dc90518b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "864ed71a-eb04-45e5-b8fa-07574a13b6e3"}}}}, {"uuid": "a1508534-c554-4a7d-ac1d-5ad0675b7b51", "name": "3ca2e239-a8d3-48d2-8295-0bd4717ea50c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3232710990419903, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5137832846214487, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f36cea0-29e7-467b-8526-a245406e1116", "name": "7874fd6c-3bb4-4bc4-ba13-b84a17dc0816", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a1508534-c554-4a7d-ac1d-5ad0675b7b51"}}}]}, {"uuid": "8295aded-e172-4d6b-a633-3b9c8e2455d9", "name": "load_p1rlv17353_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f34e3e4e-bebd-4148-bcc7-cbfbecd73a2f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f36cea0-29e7-467b-8526-a245406e1116"}}}}, {"uuid": "c9828856-d2c7-48b9-8226-5488cececd61", "name": "24908e2e-d087-4018-b785-36f46ac813b3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3232710990419903, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5137832846214487, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0add286a-19e4-4b8d-9bda-00b9c2e5fcfa", "name": "a7a56e81-5fdc-4f18-baf3-05794ccd7f2e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9828856-d2c7-48b9-8226-5488cececd61"}}}]}, {"uuid": "2767aad3-6719-4959-afa3-9482f210f809", "name": "load_p1rlv17353_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f34e3e4e-bebd-4148-bcc7-cbfbecd73a2f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0add286a-19e4-4b8d-9bda-00b9c2e5fcfa"}}}}, {"uuid": "9bc673b5-7b9b-4aa3-ad4e-22d7ec4068b9", "name": "0f4380b6-64d1-427f-8eb3-dd485b015c70_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5604078463831266, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5882122505209306, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "56dc1c65-0c11-445a-a030-11c2775fcfe1", "name": "f4992301-55dc-469d-bbd6-a908b8faa4c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9bc673b5-7b9b-4aa3-ad4e-22d7ec4068b9"}}}]}, {"uuid": "9fe63a69-17bf-46d7-8bc0-704c3f433fae", "name": "load_p1rlv17357_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf6f74e5-7aa3-4333-bd37-3ce486d54a01"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "56dc1c65-0c11-445a-a030-11c2775fcfe1"}}}}, {"uuid": "8d77143d-1380-4250-a50a-e2244879c93d", "name": "c833d713-1517-4209-bc87-50c6feb870d5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5604078463831266, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5882122505209306, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "60323c30-163d-4b00-8887-89f05a5c7679", "name": "ad5709c4-84f7-4133-b49e-13f5194ccf6e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8d77143d-1380-4250-a50a-e2244879c93d"}}}]}, {"uuid": "fa9b2054-5253-4415-8889-259ad0b84cb5", "name": "load_p1rlv17357_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf6f74e5-7aa3-4333-bd37-3ce486d54a01"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "60323c30-163d-4b00-8887-89f05a5c7679"}}}}, {"uuid": "0004e21c-fcf1-4336-8757-a830465658bd", "name": "7252e071-aae1-44aa-a36f-3458e438804d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.567401274738218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6497123013243786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b2137268-c524-4b5f-a351-ffca79fa6184", "name": "c96b7d7f-9fbb-4a4e-ac22-6c17f2a937e0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0004e21c-fcf1-4336-8757-a830465658bd"}}}]}, {"uuid": "5866fcc4-8763-4e06-8c22-e45bba83eeda", "name": "load_p1rlv17361_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c705333f-6f1a-4a76-a02e-eaa859e99b70"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b2137268-c524-4b5f-a351-ffca79fa6184"}}}}, {"uuid": "aa0b02dc-dd07-40da-953a-4563476e6b85", "name": "583fa5ad-46f4-4b34-a1fd-8b637038e0b6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.567401274738218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6497123013243786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3c48eb75-79db-455e-acea-d04d9228136e", "name": "40a2a226-9af9-465a-98a1-30ac408dc218", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aa0b02dc-dd07-40da-953a-4563476e6b85"}}}]}, {"uuid": "df57747a-1083-4403-b872-5fa1c16e3951", "name": "load_p1rlv17361_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c705333f-6f1a-4a76-a02e-eaa859e99b70"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3c48eb75-79db-455e-acea-d04d9228136e"}}}}, {"uuid": "21bb361e-140f-456c-867f-44050003f17a", "name": "a83313d8-cf7c-4295-8b8f-b5ccfde74f81_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.582045467287543, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.1165769169460202, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0344d223-50ec-43ff-9c12-5c3fae83d370", "name": "652b3ce1-f545-4216-a860-97b04ba23934", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "21bb361e-140f-456c-867f-44050003f17a"}}}]}, {"uuid": "9406461e-6e4c-4502-a0a6-9614beb56faf", "name": "load_p1rlv17378_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08709e25-b030-4801-ae00-c4879556d8b1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0344d223-50ec-43ff-9c12-5c3fae83d370"}}}}, {"uuid": "713e7ec4-ff6e-4d92-b490-46362a155cb1", "name": "1ac7f2e1-6b1d-4883-afdd-319145a5ce64_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.582045467287543, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.1165769169460202, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d0345c42-36a9-4e16-95a9-4918e096f297", "name": "37bd6084-79d6-414b-a304-86a2d943c6a4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "713e7ec4-ff6e-4d92-b490-46362a155cb1"}}}]}, {"uuid": "9e157d0c-0565-4de8-92f7-1bc70e4014bb", "name": "load_p1rlv17378_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08709e25-b030-4801-ae00-c4879556d8b1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d0345c42-36a9-4e16-95a9-4918e096f297"}}}}, {"uuid": "43bb55d1-718c-46de-8ca2-64642aa77b21", "name": "cb9facd3-eec8-422b-8dc2-06031991e10e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.833192950896713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0261472784856227, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e11461e0-e866-4176-85d0-d4ba5f5eaaf2", "name": "f44f14d3-16b1-42c3-9d87-a8f0f6e278f6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "43bb55d1-718c-46de-8ca2-64642aa77b21"}}}]}, {"uuid": "3c4a47db-8ffa-4ba2-852d-3df52e0e6aa6", "name": "load_p1rlv17383_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e1ad135-904d-47ed-ae74-32b38e1c2f88"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e11461e0-e866-4176-85d0-d4ba5f5eaaf2"}}}}, {"uuid": "6fe8413f-9acd-4df9-804d-3d71bd46fca3", "name": "b1eaef3e-9804-4d8a-a91a-acc53f697d5a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.833192950896713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0261472784856227, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6770a518-c900-41f2-a123-1488f7553cb8", "name": "259d81e9-8e67-4f7f-b719-ca0ba0de5c84", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6fe8413f-9acd-4df9-804d-3d71bd46fca3"}}}]}, {"uuid": "5212b428-d8b3-4f9a-a450-7f11c353f06e", "name": "load_p1rlv17383_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e1ad135-904d-47ed-ae74-32b38e1c2f88"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6770a518-c900-41f2-a123-1488f7553cb8"}}}}, {"uuid": "4ab1034a-22fe-4aaf-bf2b-3173f0915153", "name": "1e4d1724-790f-4aa3-a8d2-7ddcac6701a7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4147996191793286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7367936950300052, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "806d8710-c2d5-4753-b051-9ab47963f96f", "name": "7d275180-3049-4299-b88f-ef15fa8c8e3b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4ab1034a-22fe-4aaf-bf2b-3173f0915153"}}}]}, {"uuid": "356607c3-77d9-4189-9190-1ddafe1a961f", "name": "load_p1rlv17385_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e835b413-3307-49ef-ad69-cf18a5ae7cfb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "806d8710-c2d5-4753-b051-9ab47963f96f"}}}}, {"uuid": "838a242a-9611-443f-8c74-a88ff07a6caf", "name": "b2524670-8066-4464-960c-cb129261ded3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4147996191793286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7367936950300052, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4b5a2eae-e238-40d8-8baf-092e6388f195", "name": "dc596592-87c6-4f2e-aa82-a131c6439d44", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "838a242a-9611-443f-8c74-a88ff07a6caf"}}}]}, {"uuid": "4cc6a621-48bf-468c-8e56-766fac8208f2", "name": "load_p1rlv17385_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e835b413-3307-49ef-ad69-cf18a5ae7cfb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4b5a2eae-e238-40d8-8baf-092e6388f195"}}}}, {"uuid": "88b390e3-39d8-45bf-ae83-4d940000f48d", "name": "44b92c1f-cb76-49b0-900f-2ce73682d7aa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4341422169696036, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7357531788704136, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2965e5ae-a370-491d-bdb3-cc58fce2fb1b", "name": "c6281ae0-d87a-4b54-8fd1-9841a114e928", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "88b390e3-39d8-45bf-ae83-4d940000f48d"}}}]}, {"uuid": "697b77fe-e657-4fd7-b89b-d800d852f3a8", "name": "load_p1rlv17387_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "55382019-a1a5-40fd-b90a-072af40c2258"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2965e5ae-a370-491d-bdb3-cc58fce2fb1b"}}}}, {"uuid": "52de8749-2ec3-468f-a447-0c09d80b121f", "name": "b3e054d4-a5c9-4c00-bfb1-417a6151ff6c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4341422169696036, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7357531788704136, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "62c675f5-9c89-4388-b098-c8b697565974", "name": "ac2db679-d9a8-4f39-9764-967a6122356c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "52de8749-2ec3-468f-a447-0c09d80b121f"}}}]}, {"uuid": "4fa2fec5-5280-47dd-ace4-31d79610be5d", "name": "load_p1rlv17387_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "55382019-a1a5-40fd-b90a-072af40c2258"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "62c675f5-9c89-4388-b098-c8b697565974"}}}}, {"uuid": "0ca0f37c-a67b-40c0-945f-75485e693773", "name": "d89e5876-38f6-491b-ac24-1332746712e1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3557486353305213, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.524803205527562, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "229a6a7d-4723-41f9-b305-086b43fbf58e", "name": "b786ccbb-08f3-45f5-8f8d-e4fcf7fbd606", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0ca0f37c-a67b-40c0-945f-75485e693773"}}}]}, {"uuid": "f1f220d6-2c2d-4e91-bba9-6db42c260a03", "name": "load_p1rlv17391_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "169a22de-bb0a-4056-8910-151125c4ff9e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "229a6a7d-4723-41f9-b305-086b43fbf58e"}}}}, {"uuid": "3dbbb271-6748-435a-ac2a-880d5a37dc41", "name": "92c492ce-5b88-465c-8762-6a7de937bdd0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3557486353305213, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.524803205527562, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "187b5a26-62fe-4ec7-8514-c24ec27c8921", "name": "08f3dbc1-7f29-4b75-93f8-50b00087a8c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3dbbb271-6748-435a-ac2a-880d5a37dc41"}}}]}, {"uuid": "1002dba4-77bd-4cc9-b627-2a849d502d9b", "name": "load_p1rlv17391_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "169a22de-bb0a-4056-8910-151125c4ff9e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "187b5a26-62fe-4ec7-8514-c24ec27c8921"}}}}, {"uuid": "7b009349-73d7-4acb-9521-a26b06608d33", "name": "c837bdf3-fdf5-44f6-a1a8-7ee9ec55368f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.0707881481560175, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.1283140369898392, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "579385c8-f0f6-4477-b08a-a8ab9272c314", "name": "b6b4f40e-9c6f-4edf-a93e-c3923f293c9d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b009349-73d7-4acb-9521-a26b06608d33"}}}]}, {"uuid": "bb753700-3f23-44b4-b12e-611167da5587", "name": "load_p1rlv17394_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea560bcb-f930-4f42-ae45-3a60f36fdbb7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "579385c8-f0f6-4477-b08a-a8ab9272c314"}}}}, {"uuid": "3019877e-d0cb-43f8-8ab8-7519b5ad0168", "name": "82621ccf-7bba-48da-acb6-e4a98de4bbbf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.0707881481560175, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.1283140369898392, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ed8335fc-7c31-4da7-94a9-4666fecbf066", "name": "435980bf-ebd6-4c7b-9691-da263768536d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3019877e-d0cb-43f8-8ab8-7519b5ad0168"}}}]}, {"uuid": "ac8d96c4-d602-4fd1-9be2-5b10ed7c810c", "name": "load_p1rlv17394_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea560bcb-f930-4f42-ae45-3a60f36fdbb7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ed8335fc-7c31-4da7-94a9-4666fecbf066"}}}}, {"uuid": "5a5e5d7a-03e7-4a56-843e-84c1f6073e79", "name": "e496bdb3-1418-4e6b-a79b-952a4ec8d05a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.772705532239135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.33568286747913667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "70f7dfe6-a16a-426e-9286-34c5a396ced9", "name": "2979b272-bbde-4390-9125-d87da755935e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5a5e5d7a-03e7-4a56-843e-84c1f6073e79"}}}]}, {"uuid": "a69d0934-805d-44c8-8035-3bb4e1ad5e76", "name": "load_p1rlv17397_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d38cdffb-41be-48aa-8a03-c6525dd01037"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "70f7dfe6-a16a-426e-9286-34c5a396ced9"}}}}, {"uuid": "f35f7daf-422b-4ca4-af37-55eb6cef9b4c", "name": "8a1965b2-8b0c-4bc1-bc76-807ba9d11f4d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.772705532239135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.33568286747913667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dd91b777-3ae2-4333-923c-44c405bace58", "name": "0f76aa58-5610-4d56-bd20-56a677fd9318", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f35f7daf-422b-4ca4-af37-55eb6cef9b4c"}}}]}, {"uuid": "144ad946-e543-4e87-8c77-837a8d8da3b0", "name": "load_p1rlv17397_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d38cdffb-41be-48aa-8a03-c6525dd01037"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dd91b777-3ae2-4333-923c-44c405bace58"}}}}, {"uuid": "2407d8a8-67ea-4de5-9750-c11eb0683256", "name": "1db87372-bb6e-458b-a85f-4b38c1970474_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.072452566650022, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.19566580727582514, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e7c63da0-a165-46bd-aaf3-9d0575264d2f", "name": "0e15e527-5779-4f67-b1fe-61159d545837", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2407d8a8-67ea-4de5-9750-c11eb0683256"}}}]}, {"uuid": "3c899519-7224-4885-9d02-ee292723af0b", "name": "load_p1rlv17400_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63177299-2842-4e0d-bf17-7bd2b0afe9a2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e7c63da0-a165-46bd-aaf3-9d0575264d2f"}}}}, {"uuid": "3a3f2217-6cfb-4fad-89ac-4d06b8bc5bac", "name": "31309af2-1f78-4d21-9067-f5f127248951_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.072452566650022, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.19566580727582514, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d2669ad4-1f07-4b52-890e-83578641b89f", "name": "fb7a1148-b012-479a-adc2-a72ddc85c28e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3a3f2217-6cfb-4fad-89ac-4d06b8bc5bac"}}}]}, {"uuid": "7ef8ddb5-6d01-40c3-a749-97ba63adcdc0", "name": "load_p1rlv17400_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63177299-2842-4e0d-bf17-7bd2b0afe9a2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d2669ad4-1f07-4b52-890e-83578641b89f"}}}}, {"uuid": "5b874b04-da0b-4a51-bc6f-b387b1b951bd", "name": "59b22aa8-fbba-47e3-ab06-2534e76dd4d8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.799969889792979, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7055837837850989, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "24009d36-0cfe-4c27-8da0-4724252c4a08", "name": "f6c70340-8718-4978-baad-62577cbddc6d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b874b04-da0b-4a51-bc6f-b387b1b951bd"}}}]}, {"uuid": "d447dc1f-1c26-48c1-a2e3-570c6805d19c", "name": "load_p1rlv17403_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d61897a-cdac-4b4a-8812-8a8692a3d958"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "24009d36-0cfe-4c27-8da0-4724252c4a08"}}}}, {"uuid": "c1bd056d-22a3-4b0d-b9b6-30dab96ccba7", "name": "f5c00162-a7ca-4860-8b51-9d1298ee15be_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.799969889792979, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7055837837850989, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "af5e10e5-e0dc-4186-8e57-3edc6f6e524c", "name": "1efdaafa-c6c4-417f-8ea5-c2cf301c0219", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c1bd056d-22a3-4b0d-b9b6-30dab96ccba7"}}}]}, {"uuid": "764b567c-a4e5-4d1f-a784-9dda29a803e5", "name": "load_p1rlv17403_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d61897a-cdac-4b4a-8812-8a8692a3d958"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "af5e10e5-e0dc-4186-8e57-3edc6f6e524c"}}}}, {"uuid": "5c7e67f9-eb74-4072-bd15-aaf6c3dfadf1", "name": "982ef7b8-e286-439a-ae6c-c7188ec2f61a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2075389461119934, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3167249782629938, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7842d907-a8f8-4936-b8eb-c87fb3c1212a", "name": "37fe09d7-e1c6-460c-82f8-2ecbf0af9189", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5c7e67f9-eb74-4072-bd15-aaf6c3dfadf1"}}}]}, {"uuid": "e5ee68a5-e0bc-4a07-9fde-5f3a7730db64", "name": "load_p1rlv17405_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b50de14e-9a09-4f61-8998-0979f33b0d0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7842d907-a8f8-4936-b8eb-c87fb3c1212a"}}}}, {"uuid": "01b8414f-5666-464c-8250-fe528292c693", "name": "06d7800b-e9df-45f5-8302-dd539204b00e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2075389461119934, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3167249782629938, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b91c17c7-c950-4a98-bfcc-ac5bb84edf1e", "name": "c1b90e55-7f45-45e5-8a76-35326021fb6b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "01b8414f-5666-464c-8250-fe528292c693"}}}]}, {"uuid": "8a18a6a3-16ec-4cb1-a1b9-d836e6e65e29", "name": "load_p1rlv17405_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b50de14e-9a09-4f61-8998-0979f33b0d0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b91c17c7-c950-4a98-bfcc-ac5bb84edf1e"}}}}, {"uuid": "f588d3ad-fa76-478d-a91d-7bfce980b80b", "name": "3aaf73cf-4754-4d6a-a3af-42a02d25ccfd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2162240825393356, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.47013804182089236, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0be405d0-1eca-469c-80fc-ae833e8edba7", "name": "1c3b8c48-1d81-408e-94d1-45c355e21042", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f588d3ad-fa76-478d-a91d-7bfce980b80b"}}}]}, {"uuid": "a79e9642-e380-4811-94a3-a8e3ef214797", "name": "load_p1rlv17407_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65de341c-589f-4bf9-a708-26fcc94a6c0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0be405d0-1eca-469c-80fc-ae833e8edba7"}}}}, {"uuid": "39f99665-53c4-4897-8ee8-39b15c3c2d3d", "name": "90a1466b-6d62-48c2-820f-ff45af8d6778_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2162240825393356, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.47013804182089236, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ce0e992d-7170-43f0-b60a-0bc2db1ddd4f", "name": "5a438f1e-3ff8-47f7-a75c-272825c559c7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "39f99665-53c4-4897-8ee8-39b15c3c2d3d"}}}]}, {"uuid": "43efa592-e32e-40e2-bdd9-1b958d3c908d", "name": "load_p1rlv17407_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65de341c-589f-4bf9-a708-26fcc94a6c0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ce0e992d-7170-43f0-b60a-0bc2db1ddd4f"}}}}, {"uuid": "9de5024a-5503-4cee-bd35-09ef1bf4e580", "name": "7a92c937-bcf1-473f-aa95-62ac42cde235_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2816928104449037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4107329194522798, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "347d276f-d16b-46bf-99e7-1c5edbff94ab", "name": "aab4f704-c723-4488-9b50-f2debc755a5e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9de5024a-5503-4cee-bd35-09ef1bf4e580"}}}]}, {"uuid": "8350ccd7-b3f4-40f6-85b2-ccce48b7a5cd", "name": "load_p1rlv17415_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86b2527b-73c3-41c4-8ac2-7cb0e8bc2a7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "347d276f-d16b-46bf-99e7-1c5edbff94ab"}}}}, {"uuid": "b65a617e-98cd-4679-b909-11df11aba0ff", "name": "ce339973-1e65-4efc-8f33-b9f2860fe8bb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2816928104449037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4107329194522798, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "77228ec7-1d24-4bdb-933c-2eef13a771d5", "name": "37f2666b-debc-48db-b76c-446fbf120c0e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b65a617e-98cd-4679-b909-11df11aba0ff"}}}]}, {"uuid": "bd730a82-6946-45dd-849e-314b29a96e03", "name": "load_p1rlv17415_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86b2527b-73c3-41c4-8ac2-7cb0e8bc2a7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "77228ec7-1d24-4bdb-933c-2eef13a771d5"}}}}, {"uuid": "be257be2-6154-459a-9727-7434eab3ae9b", "name": "71b95e00-0e54-42ef-9fbb-ba7688857464_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.524011463187128, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7498872254128004, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d2e3f0b4-e35d-47aa-aa3c-057777b11819", "name": "16446f09-2dc2-43b1-abdd-bc9b03e70549", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "be257be2-6154-459a-9727-7434eab3ae9b"}}}]}, {"uuid": "aab56419-c994-43b3-acb6-4dc12758f78e", "name": "load_p1rlv17416_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64a56527-23a9-4229-aa25-f6a45f2187f4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d2e3f0b4-e35d-47aa-aa3c-057777b11819"}}}}, {"uuid": "9c6ca403-fd85-4b35-8892-013f17f967c1", "name": "dbeb95f5-8f49-47f6-9494-bd80cecb550e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.524011463187128, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7498872254128004, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fc931318-a8a4-493d-8371-27e3480f96e4", "name": "fea0aa3d-333a-4590-beec-7efce1279967", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9c6ca403-fd85-4b35-8892-013f17f967c1"}}}]}, {"uuid": "9361bc29-535d-4b5e-ab5c-b66b504f9f0c", "name": "load_p1rlv17416_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64a56527-23a9-4229-aa25-f6a45f2187f4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fc931318-a8a4-493d-8371-27e3480f96e4"}}}}, {"uuid": "9476faa4-9250-476c-8b03-68ef2566c80d", "name": "ee8ddc70-1c84-4dee-851c-1e58d1c6a2b7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.887268818021247, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.0124643291307467, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5031ad5c-b431-4be9-8d68-e0332e5699bb", "name": "52519b40-3f15-4cd1-b12a-27b5543ef4b5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9476faa4-9250-476c-8b03-68ef2566c80d"}}}]}, {"uuid": "c3fa75f3-7af0-4bd3-89e9-711d7614221f", "name": "load_p1rlv17417_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67003f0f-6690-469e-82c0-63949ee5241e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5031ad5c-b431-4be9-8d68-e0332e5699bb"}}}}, {"uuid": "1d75b5b1-a939-4899-9865-3e31ae1af64f", "name": "b9cbac1c-1576-4db1-a031-24fb551f1495_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.887268818021247, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.0124643291307467, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "85a852a4-0bd8-49ab-96ff-d748358a5287", "name": "b9af2d56-3844-4983-92db-339d49d0ef67", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1d75b5b1-a939-4899-9865-3e31ae1af64f"}}}]}, {"uuid": "14c2f474-05ed-47f4-a37f-e4c8361d4cb2", "name": "load_p1rlv17417_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67003f0f-6690-469e-82c0-63949ee5241e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "85a852a4-0bd8-49ab-96ff-d748358a5287"}}}}, {"uuid": "8cbbd0b1-9a4e-45dc-a1c9-b42a1661df65", "name": "3b3605a5-1da1-44ca-8aa7-b65e0fe15dd0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1219512592986662, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8685822493081499, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c8ae20d1-5b04-4bcc-a716-a7b254a720b4", "name": "7c39d8b1-a023-4667-9efd-77168170d85a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8cbbd0b1-9a4e-45dc-a1c9-b42a1661df65"}}}]}, {"uuid": "73aba28a-da22-4d76-8ef8-a166f2a20c31", "name": "load_p1rlv19574_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf457d88-958c-446a-9584-73be8c609bbe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c8ae20d1-5b04-4bcc-a716-a7b254a720b4"}}}}, {"uuid": "491cda37-a219-453c-bd7a-f818d86d7c69", "name": "d5bedc31-12ea-41fa-8b0e-3b77d6a70181_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1219512592986662, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8685822493081499, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "88ee732c-b169-4bbe-8ff7-5080f5252a9e", "name": "b827c4c3-d0e7-4405-a386-12643b337264", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "491cda37-a219-453c-bd7a-f818d86d7c69"}}}]}, {"uuid": "ebd41626-5df8-4131-9e56-6557ffebf1f1", "name": "load_p1rlv19574_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf457d88-958c-446a-9584-73be8c609bbe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "88ee732c-b169-4bbe-8ff7-5080f5252a9e"}}}}, {"uuid": "01b83cc5-088b-4535-b8c6-2f6d119cdc29", "name": "e9084385-43f4-4dcc-a766-b59a6f16cf00_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.817160338362793, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.8654854383625104, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2e5ea7d6-5d3e-4ab2-a2a8-f4b47aceb960", "name": "434ed16a-7e6f-4fc1-9fab-5afd87d35143", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "01b83cc5-088b-4535-b8c6-2f6d119cdc29"}}}]}, {"uuid": "ff4b85f9-f026-4da1-bb90-b0daebe67df4", "name": "load_p1rlv19608_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f917b142-d59f-4a51-8c3b-913feb53411d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2e5ea7d6-5d3e-4ab2-a2a8-f4b47aceb960"}}}}, {"uuid": "fc108728-c806-46c7-9d22-68ded33066cc", "name": "c02ebb55-f9f3-468b-9fc6-b92bc289e1f3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.817160338362793, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.8654854383625104, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "31ed6c2a-ae9e-4a5e-aa55-bef73c08d0d7", "name": "c516f3fc-4e7c-484f-9646-592d6aba09da", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fc108728-c806-46c7-9d22-68ded33066cc"}}}]}, {"uuid": "cd9175ba-3277-41e9-9fe7-929229dfdf54", "name": "load_p1rlv19608_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f917b142-d59f-4a51-8c3b-913feb53411d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "31ed6c2a-ae9e-4a5e-aa55-bef73c08d0d7"}}}}, {"uuid": "861b9adc-05fe-4dee-ae1f-f543c31f61eb", "name": "48772389-aa31-4394-b8e2-a2d7dccbce94_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.931347600748843, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.97768534997531, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cf3c100b-93d4-4c17-8d10-cdb0d190a302", "name": "e2672745-f7ac-400b-b48c-7b1c6bc1726e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "861b9adc-05fe-4dee-ae1f-f543c31f61eb"}}}]}, {"uuid": "3eead1e5-07f0-4ee7-84c6-07dcd4f130b0", "name": "load_p1rlv19610_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "813f887e-6807-4ffc-90bf-bd30cde9a9df"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cf3c100b-93d4-4c17-8d10-cdb0d190a302"}}}}, {"uuid": "01550101-b582-41aa-ae25-30f44134001d", "name": "28fec7d8-95f1-4a68-b4d3-a15cbfab2792_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.931347600748843, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.97768534997531, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3e1afdcd-ce9c-4989-8c68-15db2c7114bf", "name": "8255ef47-9ab6-4f7d-b7e6-8ef9d13464aa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "01550101-b582-41aa-ae25-30f44134001d"}}}]}, {"uuid": "c27da2d6-a9d3-47c2-9056-b49f5f2fff1f", "name": "load_p1rlv19610_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "813f887e-6807-4ffc-90bf-bd30cde9a9df"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3e1afdcd-ce9c-4989-8c68-15db2c7114bf"}}}}, {"uuid": "5985b63c-147a-4326-bafe-41ba848dea30", "name": "8638f04b-97f9-478b-8801-4cc733147fde_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5877230897388055, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4388767979233367, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "795a41ee-4f11-4851-bb52-ec20deb75787", "name": "52439e00-1f5a-4a03-badb-53c010a26c68", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5985b63c-147a-4326-bafe-41ba848dea30"}}}]}, {"uuid": "1296b321-b4be-4bed-8bf8-b44a0438459a", "name": "load_p1rlv19616_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be1b9922-2426-4726-9e5a-bcd33f444b57"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "795a41ee-4f11-4851-bb52-ec20deb75787"}}}}, {"uuid": "2d397e2e-5344-4333-820f-7894baf42aef", "name": "79d92001-bc92-4823-9e1c-851734be8689_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5877230897388055, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4388767979233367, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c32a656-137e-4d99-97c7-0e842dae33e9", "name": "80876c3d-d8c5-47d7-ae76-e3a9ab056fa7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2d397e2e-5344-4333-820f-7894baf42aef"}}}]}, {"uuid": "2a53dcc4-8c69-4632-b1af-ef95e2bbb525", "name": "load_p1rlv19616_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be1b9922-2426-4726-9e5a-bcd33f444b57"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c32a656-137e-4d99-97c7-0e842dae33e9"}}}}, {"uuid": "3ffd9aeb-ffaf-4c77-988f-21934028f3fb", "name": "a70da804-57f4-494b-905e-f44e64ad7b5f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.925260736902077, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.726135012516628, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "00c79078-4ffb-4f0f-855a-ca8dc265cd1e", "name": "272f4a4f-b213-4932-b85f-8e9af0e5892c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3ffd9aeb-ffaf-4c77-988f-21934028f3fb"}}}]}, {"uuid": "c74b9f6c-f9ba-4508-a774-4728d5a2ee91", "name": "load_p1rlv19640_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e90f763-682e-4771-976c-9cd736b72133"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "00c79078-4ffb-4f0f-855a-ca8dc265cd1e"}}}}, {"uuid": "c23552af-3ba4-41b2-b568-a394025c6c76", "name": "62b10e40-2852-42e5-9e8e-a772162d2bc9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.925260736902077, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.726135012516628, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6bed2d9c-e8f4-4ae5-a8c9-40896dc8e08e", "name": "3f9169a6-f8b4-41a8-b7de-17d6058ae1ac", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c23552af-3ba4-41b2-b568-a394025c6c76"}}}]}, {"uuid": "a05f7e5d-2673-4d13-a1c9-eef49f17ca26", "name": "load_p1rlv19640_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e90f763-682e-4771-976c-9cd736b72133"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6bed2d9c-e8f4-4ae5-a8c9-40896dc8e08e"}}}}, {"uuid": "56027744-baa0-42d5-8b68-edfd1bf583b5", "name": "bd45c2ed-6be0-4f81-bd1e-36effbf40114_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3571348598185444, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7897285261495656, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b736c69d-5be1-415c-a425-ec5654f8f039", "name": "a23be684-93ce-4cd6-becf-d7a52813160e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "56027744-baa0-42d5-8b68-edfd1bf583b5"}}}]}, {"uuid": "592c8ae4-e706-4b2d-a646-93ff39996f17", "name": "load_p1rlv19643_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f0e181a-fa89-4c5d-a1cb-6080f91331da"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b736c69d-5be1-415c-a425-ec5654f8f039"}}}}, {"uuid": "c814fe75-4519-48fa-ad9a-2661876cb633", "name": "1980c37a-587b-4e2b-9f3f-d44f334738a3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3571348598185444, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7897285261495656, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fe957262-5f7c-47d7-90b5-8f04f058c6e9", "name": "75889327-7bc0-4064-96ce-be904f063c04", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c814fe75-4519-48fa-ad9a-2661876cb633"}}}]}, {"uuid": "b694819c-01b7-4cb7-a06a-d517d4bd8c90", "name": "load_p1rlv19643_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f0e181a-fa89-4c5d-a1cb-6080f91331da"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fe957262-5f7c-47d7-90b5-8f04f058c6e9"}}}}, {"uuid": "84877362-3505-4637-8a0a-cdac5d81880b", "name": "e9b04e35-cdbd-4958-a7bb-35daa42ee745_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.354599726773856, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.636709731909327, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50de177e-e986-4594-8655-d4e28e80b481", "name": "3645d95c-8b84-4396-820b-2a6475d87400", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "84877362-3505-4637-8a0a-cdac5d81880b"}}}]}, {"uuid": "de328b1d-637f-4e00-8587-c7674fc4b3e2", "name": "load_p1rlv19645_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7efbb32-55d4-409b-a37f-bf01d0620d40"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50de177e-e986-4594-8655-d4e28e80b481"}}}}, {"uuid": "1c560954-9a26-45dc-824c-d2fd2586fc48", "name": "41a3ab7d-0a41-4f58-b572-b432521ee0df_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.354599726773856, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.636709731909327, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d50067a1-8c81-4f68-954a-fc8fab41c905", "name": "e0e37918-3471-4814-afda-69fb3338c899", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1c560954-9a26-45dc-824c-d2fd2586fc48"}}}]}, {"uuid": "db057238-fe08-440a-8938-d471bbdb491b", "name": "load_p1rlv19645_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7efbb32-55d4-409b-a37f-bf01d0620d40"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d50067a1-8c81-4f68-954a-fc8fab41c905"}}}}, {"uuid": "5cfa9f24-fb2e-49eb-9407-fed20b015f3b", "name": "d379a36f-5756-47b3-8ca0-a98f811e3598_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1763634802125313, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8050824744595734, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5c1a0340-3f57-4656-98ff-967ad63d2363", "name": "73089cdc-992d-4e0e-91de-9f8dea577196", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5cfa9f24-fb2e-49eb-9407-fed20b015f3b"}}}]}, {"uuid": "b5a20c0a-b9dd-4aba-8196-cf6292d1eb80", "name": "load_p1rlv19683_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19894180-0890-4585-b4e2-55500af3c41a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5c1a0340-3f57-4656-98ff-967ad63d2363"}}}}, {"uuid": "20fee792-37d4-4207-9023-dd663ac217a8", "name": "d4b61c7e-2966-4cd3-86b5-207b3da141d7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1763634802125313, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8050824744595734, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a455b71-a883-4b54-abf0-167c0928995b", "name": "4d363972-a584-4fc8-8320-0827e3556b23", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "20fee792-37d4-4207-9023-dd663ac217a8"}}}]}, {"uuid": "36f8c773-9a3e-4bae-b0db-fc25a31d0d23", "name": "load_p1rlv19683_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19894180-0890-4585-b4e2-55500af3c41a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a455b71-a883-4b54-abf0-167c0928995b"}}}}, {"uuid": "98cab855-e394-4444-8423-672ff982150f", "name": "b1b5f5e3-d8d1-4f6f-8b7b-4b1c42aaf35b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7055277650263714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24030088917661724, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a85f6b6-de93-4523-9c7d-1ace1ea283ec", "name": "aae51e6e-b2e7-4c5f-b5d0-d72d3b04a775", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "98cab855-e394-4444-8423-672ff982150f"}}}]}, {"uuid": "2adf5309-aace-4f00-bed6-ed4e7bf836ce", "name": "load_p1rlv37689_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f827fe9e-1ffe-456c-a57b-c3374aef8ad8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0a85f6b6-de93-4523-9c7d-1ace1ea283ec"}}}}, {"uuid": "c87318a7-0a2d-4353-959c-35db301a0857", "name": "2d96a672-ef1f-4027-9e52-530ec682c50e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7055277650263714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24030088917661724, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8ec9c9b7-ab9f-491f-9c1e-32faf27ddc30", "name": "c7f10edc-5d68-4589-89e7-b23d4b7e966b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c87318a7-0a2d-4353-959c-35db301a0857"}}}]}, {"uuid": "858d9eec-d859-4213-9573-c97d163c8c71", "name": "load_p1rlv37689_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f827fe9e-1ffe-456c-a57b-c3374aef8ad8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8ec9c9b7-ab9f-491f-9c1e-32faf27ddc30"}}}}, {"uuid": "86aabb6c-bae3-4a95-8565-6a0e0c767b23", "name": "0404afe2-c99a-439e-bec4-76d53cb6dc65_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.991433457795887, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5982568468826307, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6b10a72c-3057-428c-b0c4-5cd3762cd47c", "name": "623fd40d-3aab-4ef4-96dc-6464c1c13bff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "86aabb6c-bae3-4a95-8565-6a0e0c767b23"}}}]}, {"uuid": "2b4781d6-4030-4d0b-9b8d-26f217c668e9", "name": "load_p1rlv37691_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da3cd593-6f05-41ba-9609-f6f1e307e998"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6b10a72c-3057-428c-b0c4-5cd3762cd47c"}}}}, {"uuid": "5493cb3e-8215-40c5-9d74-817a0fa2af4a", "name": "7dd65da8-bc6e-404d-9358-d414e807e6df_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.991433457795887, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5982568468826307, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b0f43b4f-d9a9-4d34-bf7f-629916a21f88", "name": "c48de185-469d-4a88-bc12-b03777829130", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5493cb3e-8215-40c5-9d74-817a0fa2af4a"}}}]}, {"uuid": "4561c13f-6bf9-4990-a9e7-23a58b2df2e8", "name": "load_p1rlv37691_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da3cd593-6f05-41ba-9609-f6f1e307e998"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b0f43b4f-d9a9-4d34-bf7f-629916a21f88"}}}}, {"uuid": "c77b0fe6-fd6d-423f-9782-f42f4e139504", "name": "3d48ae85-0040-459a-9849-d48248b838ae_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9233060787231575, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.431469772224645, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8b877d53-04ab-4102-874b-cb892fa21f1f", "name": "0011e870-a629-4810-b98a-1dcd94344fa9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c77b0fe6-fd6d-423f-9782-f42f4e139504"}}}]}, {"uuid": "c4eccd81-0ac9-473f-b1b0-50cd3a52c637", "name": "load_p1rlv37703_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01c9efda-0adf-4932-8f54-2938964371d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8b877d53-04ab-4102-874b-cb892fa21f1f"}}}}, {"uuid": "83dfc415-cd1b-40d8-ad51-de06357e06e5", "name": "fbc35b91-860a-4f01-aeea-64536975e4c5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9233060787231575, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.431469772224645, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0691e60b-1d86-4f19-b917-91d72314e28f", "name": "9e6c4158-1c0b-4ddb-917a-70f78209c62b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "83dfc415-cd1b-40d8-ad51-de06357e06e5"}}}]}, {"uuid": "2653101b-973b-4458-840e-2d2e1856bb38", "name": "load_p1rlv37703_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01c9efda-0adf-4932-8f54-2938964371d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0691e60b-1d86-4f19-b917-91d72314e28f"}}}}, {"uuid": "1a073c58-9dd9-412e-a2fa-dff5fafef051", "name": "f58579e3-c492-435b-a453-142e6abb9e9c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5500863393357383, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3576036143879098, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a7e703dd-da55-44a3-9e7c-14d344c4d2fc", "name": "62ec24a3-0acd-41eb-ba42-3ffd327e1896", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1a073c58-9dd9-412e-a2fa-dff5fafef051"}}}]}, {"uuid": "cc3f5d8c-a0ce-49d0-920a-f2fa6fddc0a1", "name": "load_p1rlv37710_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38bda697-2888-467e-bab0-62896a62503f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a7e703dd-da55-44a3-9e7c-14d344c4d2fc"}}}}, {"uuid": "b7358bdb-3dff-4dd8-a8b7-700381fa7043", "name": "ccf907b8-6bd1-45fe-bafe-b26b9ecbaf16_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5500863393357383, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3576036143879098, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "394f38b0-a2d4-48fe-b92e-e2df4d1a8720", "name": "1195b5b4-2083-4043-a818-76e24534b81d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b7358bdb-3dff-4dd8-a8b7-700381fa7043"}}}]}, {"uuid": "534db35e-7b40-4f9d-a0fd-a97b5e54190a", "name": "load_p1rlv37710_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38bda697-2888-467e-bab0-62896a62503f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "394f38b0-a2d4-48fe-b92e-e2df4d1a8720"}}}}, {"uuid": "6f56ae76-1918-43f7-89a3-77b983b8bb29", "name": "b722e849-b111-4203-855b-f505ba11eb7b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2045141672666357, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3046267940472902, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b364fae8-133e-49f4-b5a3-761aad2becc9", "name": "f4ac8e2a-7c9b-4795-959b-cd96e9b89fb5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6f56ae76-1918-43f7-89a3-77b983b8bb29"}}}]}, {"uuid": "9e3f743f-e24d-486d-85ae-927080312cd0", "name": "load_p1rlv37732_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d998a0-628e-4009-a6c8-07af906f6d43"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b364fae8-133e-49f4-b5a3-761aad2becc9"}}}}, {"uuid": "ebe3272a-9772-4c74-876b-eeca1b7cebc0", "name": "6fecf92d-9e03-4f24-9d19-d5a6046488d2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2045141672666357, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3046267940472902, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cc9452be-8e52-4b91-96d8-092b3a3c5c39", "name": "ac7cf685-62c6-47f5-af2f-2c0d68dd981a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ebe3272a-9772-4c74-876b-eeca1b7cebc0"}}}]}, {"uuid": "f94b41ae-f7e2-45a9-8982-d1f2a4c17754", "name": "load_p1rlv37732_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d998a0-628e-4009-a6c8-07af906f6d43"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cc9452be-8e52-4b91-96d8-092b3a3c5c39"}}}}, {"uuid": "c2393e52-03c1-41ff-a32e-c1ac1d17ba93", "name": "776d405b-dd5a-49ab-aeea-98dcac4f6649_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.106965589535082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4202201192794711, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2ee241d8-7db3-4353-858e-63fdc838be4d", "name": "14dad654-46fe-471d-ad8d-bbf20a170c22", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c2393e52-03c1-41ff-a32e-c1ac1d17ba93"}}}]}, {"uuid": "15228525-13a8-4f68-9e9a-afeb20048a91", "name": "load_p1rlv37776_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b24da1e-9a6e-4545-9ad4-a9f0e9675fd1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2ee241d8-7db3-4353-858e-63fdc838be4d"}}}}, {"uuid": "a0ed8fb5-9e42-4c0e-873b-cf78be7f20be", "name": "372a9612-a533-4703-8742-e10f26fd3696_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.106965589535082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4202201192794711, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e80daaf8-3d12-4628-8de2-e4372eedada7", "name": "121fa53a-e7f5-4720-8f34-227d39a96dd8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a0ed8fb5-9e42-4c0e-873b-cf78be7f20be"}}}]}, {"uuid": "306bb777-27dc-416c-96b8-0447cad5164d", "name": "load_p1rlv37776_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b24da1e-9a6e-4545-9ad4-a9f0e9675fd1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e80daaf8-3d12-4628-8de2-e4372eedada7"}}}}, {"uuid": "d93d7ca7-c729-4125-bfd0-2f82fa5a471f", "name": "9fd20af8-340a-405a-9370-74c501099235_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2167250892906645, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5534364726692191, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "734a6bb3-dae1-4e22-be5d-527c73a6540a", "name": "2b66fee4-6134-478a-b846-d39ac761d1b5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d93d7ca7-c729-4125-bfd0-2f82fa5a471f"}}}]}, {"uuid": "a68c442d-21fb-41e6-95df-690b8cd20ab7", "name": "load_p1rlv37778_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5aaed5d-8312-4707-a047-634e433bf49f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "734a6bb3-dae1-4e22-be5d-527c73a6540a"}}}}, {"uuid": "139fc5dd-4ca9-4a4e-82e3-8b80b42bb469", "name": "9c3a510f-8e0a-4448-bc99-f8bae25c5d9f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2167250892906645, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5534364726692191, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "86030c64-9459-40d0-b8e1-71d5ae1714d0", "name": "924ac7c7-beb4-4989-b768-0880dcd98530", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "139fc5dd-4ca9-4a4e-82e3-8b80b42bb469"}}}]}, {"uuid": "e486422a-1d43-4a96-bc12-12ab56910f1a", "name": "load_p1rlv37778_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5aaed5d-8312-4707-a047-634e433bf49f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "86030c64-9459-40d0-b8e1-71d5ae1714d0"}}}}, {"uuid": "74ee0370-3552-4051-b115-3d9a4a803ca9", "name": "1d4e7e8d-41c6-4b7c-9fe1-c52d8786e85b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.902887215219663, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.111231385342157, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4bb58eb7-9b1b-49ed-be9f-dd90df587a32", "name": "5255aa2d-5cfc-4751-b610-3faf2f23d324", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "74ee0370-3552-4051-b115-3d9a4a803ca9"}}}]}, {"uuid": "d440d345-0229-4755-b7a7-bd7e8c8d8d62", "name": "load_p1rlv37782_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d7181ee-ef64-4ded-b619-00ac09d55bf5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4bb58eb7-9b1b-49ed-be9f-dd90df587a32"}}}}, {"uuid": "2f33d06a-54a0-48c0-bfcf-aec8a3f39520", "name": "45c722ba-3606-42aa-801a-02dbe9f10be2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.902887215219663, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.111231385342157, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "35d7c016-72d7-473e-b225-83d5a38ed0ad", "name": "086f70d3-b36c-4f63-bbbd-4ecc9a894bab", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2f33d06a-54a0-48c0-bfcf-aec8a3f39520"}}}]}, {"uuid": "5c8f4d9e-dd5b-4d8a-be06-f85681e95b9d", "name": "load_p1rlv37782_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d7181ee-ef64-4ded-b619-00ac09d55bf5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "35d7c016-72d7-473e-b225-83d5a38ed0ad"}}}}, {"uuid": "0e1bf61f-7a87-4871-aa7b-22c7e79ee653", "name": "79649c1e-e16e-4278-89ec-21d847472dda_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9179777962446224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3481400399277513, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a2723ae6-1a19-4f11-bd92-98787ee42be2", "name": "5d77a13a-856c-45bf-8e0f-19b712c6e3a3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0e1bf61f-7a87-4871-aa7b-22c7e79ee653"}}}]}, {"uuid": "8d154921-728c-48a5-b4a7-bcc8c97708bb", "name": "load_p1rlv38046_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10be49a0-301a-4c7e-8ab7-49c14e483079"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a2723ae6-1a19-4f11-bd92-98787ee42be2"}}}}, {"uuid": "ed625f7a-68a1-410e-b8df-84452f66f6b8", "name": "59123853-e958-47af-b720-f91604eef741_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9179777962446224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3481400399277513, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8faee505-53f5-47af-9023-87d9ff1df03b", "name": "9eef8f72-c435-49be-afdb-c937371c9361", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ed625f7a-68a1-410e-b8df-84452f66f6b8"}}}]}, {"uuid": "4af84904-a5e3-4004-9f0c-6ed1b7231689", "name": "load_p1rlv38046_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10be49a0-301a-4c7e-8ab7-49c14e483079"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8faee505-53f5-47af-9023-87d9ff1df03b"}}}}, {"uuid": "1df809e0-3274-4384-9c54-d21577f02b53", "name": "4938b5d6-73b1-485a-9b79-9c1f12c4f1a8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.567401274738218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6497123013243786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5b46ccb1-8f48-4fbc-9c82-e415a0ad9d07", "name": "42eb82be-9e48-4f8c-b18a-eeadcad25a56", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1df809e0-3274-4384-9c54-d21577f02b53"}}}]}, {"uuid": "dfde6f3a-b403-417f-8c61-c644f709f0d3", "name": "load_p1rlv38047_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0935a86b-b9fb-4058-8381-a41f67d6c9dd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5b46ccb1-8f48-4fbc-9c82-e415a0ad9d07"}}}}, {"uuid": "f5f4bd81-a812-4107-ac47-065bed44c722", "name": "fc72493e-0be6-4f75-9cb3-001f243338b0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.567401274738218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6497123013243786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7aee0163-ee99-4c05-95b5-44654457a3cc", "name": "f08bd294-0d21-416b-8f98-1b1cc7cdc5a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f5f4bd81-a812-4107-ac47-065bed44c722"}}}]}, {"uuid": "f4651df5-82c7-4ab0-bd4e-5137e3353b1f", "name": "load_p1rlv38047_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0935a86b-b9fb-4058-8381-a41f67d6c9dd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7aee0163-ee99-4c05-95b5-44654457a3cc"}}}}, {"uuid": "a01cc709-6a93-436c-be8f-404385b978ed", "name": "0341cac6-411d-407b-bb85-f0594adc83fc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7055277650263714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24030088917661724, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "57c21e44-3c60-41c7-bf81-b13fffe7fa16", "name": "cf4d6a99-9857-443c-99c3-64407ec0a059", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a01cc709-6a93-436c-be8f-404385b978ed"}}}]}, {"uuid": "bdfa7b18-fee2-4bf2-9188-13278de4f43f", "name": "load_p1rlv38048_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5da7ff68-5f4c-4d56-88fc-7736df03c0bf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "57c21e44-3c60-41c7-bf81-b13fffe7fa16"}}}}, {"uuid": "f1942386-e836-4587-bcf8-0c1144583744", "name": "896c9f6e-9acb-4270-a40c-35a23d98683d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7055277650263714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24030088917661724, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4227af12-679c-41e9-9c94-3eed1c08f7c6", "name": "a47147a2-c190-4c6e-985d-d08f6c5a3735", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f1942386-e836-4587-bcf8-0c1144583744"}}}]}, {"uuid": "e924c390-81b4-455c-9168-e1bd8492dbef", "name": "load_p1rlv38048_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5da7ff68-5f4c-4d56-88fc-7736df03c0bf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4227af12-679c-41e9-9c94-3eed1c08f7c6"}}}}, {"uuid": "2c6e618c-9bd8-4a23-907b-e1b1054dc113", "name": "45e67a46-945d-46bc-a0e1-2da48c439ab3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3461402320099836, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.810674183062217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4a1be0c9-b577-4e0b-af32-43b02a73f6c3", "name": "71d6dfc0-198c-4a85-bcd4-d01618dd45d9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2c6e618c-9bd8-4a23-907b-e1b1054dc113"}}}]}, {"uuid": "1ad5c597-4a47-4353-9489-946f00e9c421", "name": "load_p1rlv38050_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cafc6c03-240d-499d-a3d8-983b554dd007"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4a1be0c9-b577-4e0b-af32-43b02a73f6c3"}}}}, {"uuid": "f4508784-7f40-4dc9-ad9d-315d99b5c956", "name": "2d00b450-e4c5-4f89-b86e-a120c04dcc5c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3461402320099836, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.810674183062217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "302ac0e1-a6d5-4edc-9313-27fe87f5939b", "name": "9dd76531-cda9-4ed8-a169-0315ae4c992e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f4508784-7f40-4dc9-ad9d-315d99b5c956"}}}]}, {"uuid": "cf8abd4e-54cb-4645-9afe-f58ba3325547", "name": "load_p1rlv38050_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cafc6c03-240d-499d-a3d8-983b554dd007"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "302ac0e1-a6d5-4edc-9313-27fe87f5939b"}}}}, {"uuid": "2db1953f-8ac5-4836-9b25-02934a423246", "name": "3fefc103-bd15-49d7-87e5-56ada79cf4ce_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5229589832640044, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3359880712066463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3a6e37bd-3209-44ad-9074-aa81b0812b1d", "name": "324d4778-60b7-42fc-9066-ef23bde6e01f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2db1953f-8ac5-4836-9b25-02934a423246"}}}]}, {"uuid": "14f17525-bfe4-475a-a678-6316279102a6", "name": "load_p1rlv38052_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9db6122d-1e51-46ac-9cea-ac436e189cd8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3a6e37bd-3209-44ad-9074-aa81b0812b1d"}}}}, {"uuid": "00387573-1e1f-4645-9f4f-ec988a7e403d", "name": "fc70e151-175c-4ed3-b3d0-797ba65b6651_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5229589832640044, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3359880712066463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7df7a2f1-c087-4459-b464-df267e33d2ac", "name": "0170b546-2ac5-4288-bcaf-bbd96c66050c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "00387573-1e1f-4645-9f4f-ec988a7e403d"}}}]}, {"uuid": "aa000fe1-41ac-4646-98a4-d4d129240649", "name": "load_p1rlv38052_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9db6122d-1e51-46ac-9cea-ac436e189cd8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7df7a2f1-c087-4459-b464-df267e33d2ac"}}}}, {"uuid": "ddba05ec-071b-41c5-8bb7-5c3b8a924a32", "name": "4d7fe478-3369-4513-8f00-61cbffbd24de_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6912886909314806, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4972799611827758, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "49edfd08-7cb8-48ad-97ae-f3c8d7f24eae", "name": "069b9506-9dda-4954-a57a-b0e605bcff0b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ddba05ec-071b-41c5-8bb7-5c3b8a924a32"}}}]}, {"uuid": "37ee0175-44d4-4a8b-b904-22f3be239243", "name": "load_p1rlv38414_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a25b3511-86cf-404e-944f-273d3f94c05a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "49edfd08-7cb8-48ad-97ae-f3c8d7f24eae"}}}}, {"uuid": "72dc9b8f-422e-469c-8384-57ec67ffd3dd", "name": "178b63c7-ed29-45ce-b987-87d42a938880_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6912886909314806, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4972799611827758, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e05fa500-dcfe-4eb0-a404-e10a89b8bfb5", "name": "8f8ed8fa-059c-467b-919c-368f708c9254", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72dc9b8f-422e-469c-8384-57ec67ffd3dd"}}}]}, {"uuid": "03aafef1-9f4a-40c0-ab85-7f1c8f3ca2d4", "name": "load_p1rlv38414_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a25b3511-86cf-404e-944f-273d3f94c05a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e05fa500-dcfe-4eb0-a404-e10a89b8bfb5"}}}}, {"uuid": "922dde16-f073-4cba-89cd-a40353cca45c", "name": "ebf5b4b2-e731-4331-be5b-f322820089ad_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6878718453957338, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9600190343762964, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8cebfff3-32a0-4c4c-a852-dfa1f641987d", "name": "bda622e7-45b3-4ff7-867c-481d3a79b9c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "922dde16-f073-4cba-89cd-a40353cca45c"}}}]}, {"uuid": "51a15ddd-7db2-4da1-a796-936153825f09", "name": "load_p1rlv38417_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "201112bb-3dc7-4a15-9af6-155626ac1ae5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8cebfff3-32a0-4c4c-a852-dfa1f641987d"}}}}, {"uuid": "2c8a9662-1226-4af2-aecf-f8cd908d8f43", "name": "22ef792c-56e0-4d18-9df7-f59e6a870b97_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6878718453957338, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9600190343762964, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1605947c-01ca-43fe-af9e-54f7a5d541dc", "name": "26506bde-e643-4406-af63-c70ff8a8c062", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2c8a9662-1226-4af2-aecf-f8cd908d8f43"}}}]}, {"uuid": "e24cf5b6-9e5c-424f-9d57-f2710d51ee80", "name": "load_p1rlv38417_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "201112bb-3dc7-4a15-9af6-155626ac1ae5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1605947c-01ca-43fe-af9e-54f7a5d541dc"}}}}, {"uuid": "40bee9c3-6f8e-4820-9b82-c561e4dd8cd5", "name": "b3e8f28b-546c-4b70-ae2f-cbfd56534bb2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1e9537dc-a42d-4f9d-82f4-d287f4a35c2f", "name": "d1e6d7cd-2d4c-443f-a229-feddf0d9f0f7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "40bee9c3-6f8e-4820-9b82-c561e4dd8cd5"}}}]}, {"uuid": "00fe2b7b-033a-492a-8759-3b3af439d698", "name": "load_p1rlv38419_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6e4595c-0ad9-4501-b86f-c559917d4b86"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1e9537dc-a42d-4f9d-82f4-d287f4a35c2f"}}}}, {"uuid": "4b9d5d48-e313-4aaa-b53d-24fccd78187f", "name": "a2179bea-f33a-48c1-bc9f-61ae16e84437_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6e0f2455-0479-4f0c-a49f-27a274acd027", "name": "e69754bc-3284-4f21-aca4-5b9887bc5486", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4b9d5d48-e313-4aaa-b53d-24fccd78187f"}}}]}, {"uuid": "679b326d-63be-4613-8983-a59fc0fa4c32", "name": "load_p1rlv38419_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6e4595c-0ad9-4501-b86f-c559917d4b86"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6e0f2455-0479-4f0c-a49f-27a274acd027"}}}}, {"uuid": "5e332f41-3784-41b1-bdd5-1b456b231b94", "name": "223ee756-b983-49a0-a8d7-5da73d7a9854_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4437884187508536, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6647073432497462, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "08881b61-ad46-4516-8ea2-fd49b9927b0d", "name": "207cf4ad-47c0-4517-9b0a-4cff9241790a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5e332f41-3784-41b1-bdd5-1b456b231b94"}}}]}, {"uuid": "8e95af66-31ca-450a-9aca-8e106892bc76", "name": "load_p1rlv38535_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0764c32-4f46-473a-9a72-cccc45ae28d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "08881b61-ad46-4516-8ea2-fd49b9927b0d"}}}}, {"uuid": "f31c8764-bc97-4b4f-9cde-1bff89246fc5", "name": "9a7854f0-9599-41e2-9500-3224aa894639_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4437884187508536, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6647073432497462, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ca22f49a-9bb5-4730-9763-f1547662a06c", "name": "31ed3613-f5be-4a5d-8fd7-4c68c8981c8f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f31c8764-bc97-4b4f-9cde-1bff89246fc5"}}}]}, {"uuid": "58393dd1-90b2-4398-bbe7-3f69c8f25e00", "name": "load_p1rlv38535_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0764c32-4f46-473a-9a72-cccc45ae28d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ca22f49a-9bb5-4730-9763-f1547662a06c"}}}}, {"uuid": "d454f0ed-1569-430e-a940-9d11311f731b", "name": "f04f697d-37ba-4d73-95d1-f96a5f7ecc37_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5614762943111877, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5370528430833497, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d0dc1e81-ba82-445e-b840-c4eb3368537d", "name": "65336003-5aff-4e73-9c30-20dfe7f3ad78", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d454f0ed-1569-430e-a940-9d11311f731b"}}}]}, {"uuid": "d8642f17-a073-4fc4-b101-e1bde0153ea3", "name": "load_p1rlv38536_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ff930f9-63f0-4cab-b74a-3db7eb99f9eb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d0dc1e81-ba82-445e-b840-c4eb3368537d"}}}}, {"uuid": "5f99d8e8-222c-428c-b58d-bedefaed8cff", "name": "34fb25d7-73ca-40bd-a16e-924046d35039_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5614762943111877, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5370528430833497, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7717126d-86db-447c-b9ee-e99387684c27", "name": "7a840a3c-59e7-403f-850b-0ed4f56e8cda", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5f99d8e8-222c-428c-b58d-bedefaed8cff"}}}]}, {"uuid": "f132d970-074f-4152-9cf2-133e45e0e521", "name": "load_p1rlv38536_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ff930f9-63f0-4cab-b74a-3db7eb99f9eb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7717126d-86db-447c-b9ee-e99387684c27"}}}}, {"uuid": "70674b72-a9af-4244-a49c-a946d23cd5d4", "name": "bceb8436-c19d-430a-8583-8e705606fc45_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.025577912376512, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6479907691217454, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4b2e37ea-aabf-48dc-8e2b-7f18d626f96c", "name": "e3309c21-0a36-47e8-86bb-7cc362d97460", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "70674b72-a9af-4244-a49c-a946d23cd5d4"}}}]}, {"uuid": "80296163-decf-4c33-9c29-f346c1e8894b", "name": "load_p1rlv38638_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a3851f7-2dd3-447b-918f-7a8c954f21d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4b2e37ea-aabf-48dc-8e2b-7f18d626f96c"}}}}, {"uuid": "5f88a3fa-aabe-40f5-98e8-b4c86b5127f2", "name": "14f0875b-323b-4763-accf-cc6bcf457c6a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.025577912376512, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6479907691217454, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "821814a0-8f88-41d6-833d-160deb4cc4d3", "name": "ecc2ace6-5ab0-40de-9f3b-4ca05e791e59", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5f88a3fa-aabe-40f5-98e8-b4c86b5127f2"}}}]}, {"uuid": "23e8e6e7-c753-4b47-b081-311d3606c52a", "name": "load_p1rlv38638_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a3851f7-2dd3-447b-918f-7a8c954f21d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "821814a0-8f88-41d6-833d-160deb4cc4d3"}}}}, {"uuid": "e0395ca4-5b57-46fa-a42b-a3439c90eed9", "name": "6be7f68a-6e69-4489-b82d-f3b9a8918363_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9441129975170507, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3957038740694923, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f9262875-977b-478e-9cf8-77465f491ce9", "name": "6be7f68a-6e69-4489-b82d-f3b9a8918363_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9441129975170507, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3957038740694923, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8ff257d5-f8f4-44d2-bef4-ea55e776524c", "name": "6be7f68a-6e69-4489-b82d-f3b9a8918363_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9441129975170507, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3957038740694923, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "636fdd99-94b2-4fd8-92ef-dd9197f93ae7", "name": "e70df2d2-9cd0-4d1a-944e-4f0ab30a0962", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e0395ca4-5b57-46fa-a42b-a3439c90eed9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f9262875-977b-478e-9cf8-77465f491ce9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ff257d5-f8f4-44d2-bef4-ea55e776524c"}}}]}, {"uuid": "e184e575-2f3d-45e6-be66-31e4057bd428", "name": "load_p1rlv12518", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72f659b6-d302-4887-a2f6-1a477ad3324c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "636fdd99-94b2-4fd8-92ef-dd9197f93ae7"}}}}, {"uuid": "c5214aa9-c215-401b-9460-cc4c162c5548", "name": "b3583558-bd86-450e-bf77-a42b5aedf621_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3777678420633588, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24446119545004893, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0735b653-7b01-4570-a36e-ceb8ba68e689", "name": "b3583558-bd86-450e-bf77-a42b5aedf621_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3777678420633588, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24446119545004893, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ea3aef81-1188-4650-b68c-5f1a6b83a171", "name": "b3583558-bd86-450e-bf77-a42b5aedf621_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3777678420633588, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24446119545004893, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "afe2c2f2-60ae-474a-84c9-2fb36790d4c8", "name": "26e5f4ef-16f1-46f8-9a3e-9b9ceea7fc24", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c5214aa9-c215-401b-9460-cc4c162c5548"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0735b653-7b01-4570-a36e-ceb8ba68e689"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ea3aef81-1188-4650-b68c-5f1a6b83a171"}}}]}, {"uuid": "f2fb4ebc-698b-4e4f-81b1-6f918e58f23b", "name": "load_p1rlv12528", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9660b80-0fce-4be4-b541-743d5811133c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "afe2c2f2-60ae-474a-84c9-2fb36790d4c8"}}}}, {"uuid": "d799aa9a-afa6-40bc-be59-538d75cef5f6", "name": "e4ebfcf1-30b4-48e9-846b-9c02955861b4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5605855582192873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.02826560468920274, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b12c6d01-4460-4311-a904-c5d13143e75b", "name": "e4ebfcf1-30b4-48e9-846b-9c02955861b4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5605855582192873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.02826560468920274, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "37ef4d0b-b249-4220-a095-69f148aae9ad", "name": "e4ebfcf1-30b4-48e9-846b-9c02955861b4_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5605855582192873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.02826560468920274, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e482f27d-250f-4b0d-8721-098972b804e9", "name": "ca91ac77-bba4-4c41-bf16-c13e29e3f08d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d799aa9a-afa6-40bc-be59-538d75cef5f6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b12c6d01-4460-4311-a904-c5d13143e75b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "37ef4d0b-b249-4220-a095-69f148aae9ad"}}}]}, {"uuid": "c339ffc7-6711-43e4-a6ff-fd769736859f", "name": "load_p1rlv12534", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8796d817-aad6-4d22-b3d4-baf8a686c9df"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e482f27d-250f-4b0d-8721-098972b804e9"}}}}, {"uuid": "a89241f1-f525-4741-95f7-15ebe25f2bf7", "name": "ef38231c-6604-44b3-8ec3-f055074b9f60_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.424752506471074, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.0314252036301887, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "908dbfa2-35f6-4640-9846-29f2d49780b9", "name": "ef38231c-6604-44b3-8ec3-f055074b9f60_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.424752506471074, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.0314252036301887, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "777d5c0c-a10b-4048-97cf-3f3b8987e260", "name": "ef38231c-6604-44b3-8ec3-f055074b9f60_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.424752506471074, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.0314252036301887, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "980ad2f3-5855-4bdc-a897-8daa2e64c474", "name": "136af5b7-a726-451f-900a-e124c28ab761", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a89241f1-f525-4741-95f7-15ebe25f2bf7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "908dbfa2-35f6-4640-9846-29f2d49780b9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "777d5c0c-a10b-4048-97cf-3f3b8987e260"}}}]}, {"uuid": "a74387f0-d972-424b-a0e5-b02d4661ba19", "name": "load_p1rlv12536", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e89452f3-ce44-46d3-a259-f66044e01c2c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "980ad2f3-5855-4bdc-a897-8daa2e64c474"}}}}, {"uuid": "9fa1b332-67ae-4b1c-b3e6-f7a01d4f4309", "name": "e72d8412-519c-4c9b-91b4-d30cabeed95e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0622945809345516, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23624651294541713, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "29f0f8e2-d893-4275-8fee-fc83bc3daa0f", "name": "e72d8412-519c-4c9b-91b4-d30cabeed95e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0622945809345516, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23624651294541713, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c5aa709c-3d6e-4efe-be9c-b404f5629251", "name": "e72d8412-519c-4c9b-91b4-d30cabeed95e_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0622945809345516, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23624651294541713, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5629edce-626f-4f5b-b520-c93cfdc3cc70", "name": "3e0e46c7-cb9f-493c-aa0d-20896a8d1c74", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9fa1b332-67ae-4b1c-b3e6-f7a01d4f4309"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "29f0f8e2-d893-4275-8fee-fc83bc3daa0f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c5aa709c-3d6e-4efe-be9c-b404f5629251"}}}]}, {"uuid": "930c0be3-c6a4-412b-beaf-86f6ec4e901e", "name": "load_p1rlv12985", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df3aae83-f4b0-4db2-9301-dff1664ac23e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5629edce-626f-4f5b-b520-c93cfdc3cc70"}}}}, {"uuid": "ddcd9421-d4d4-4ef3-9f27-f7b5eb64edb3", "name": "24b8b12b-5d1b-46af-a09c-026c4839e859_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.23597191427304684, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09897102743265196, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "379f3f51-cca1-443a-a710-48a9a2856435", "name": "24b8b12b-5d1b-46af-a09c-026c4839e859_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.23597191427304684, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09897102743265196, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ca194c22-8ad4-4093-9b0a-df28ce7dc6d2", "name": "24b8b12b-5d1b-46af-a09c-026c4839e859_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.23597191427304684, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09897102743265196, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8cbaefc5-2d8b-49c8-9e44-885cf1424ae4", "name": "d9bbcea0-08b6-43e9-a41d-40b6878a1638", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ddcd9421-d4d4-4ef3-9f27-f7b5eb64edb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "379f3f51-cca1-443a-a710-48a9a2856435"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ca194c22-8ad4-4093-9b0a-df28ce7dc6d2"}}}]}, {"uuid": "d5cde358-4af8-4e17-9e0a-74099ddb837c", "name": "load_p1rlv16411", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ed6276c-a57b-40be-a1f1-34aaaba0ac28"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8cbaefc5-2d8b-49c8-9e44-885cf1424ae4"}}}}, {"uuid": "75af38b7-bb56-4c47-8f76-f921a8286af9", "name": "77502651-0c93-4d82-9ec9-c1e25cf5e25a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7828407995320632, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7683556122374539, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "547c1fb1-1e21-43de-9124-e75a72e23d31", "name": "77502651-0c93-4d82-9ec9-c1e25cf5e25a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7828407995320632, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7683556122374539, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6a9f4749-ed1a-46fc-8dfa-46c60b940f65", "name": "77502651-0c93-4d82-9ec9-c1e25cf5e25a_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7828407995320632, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7683556122374539, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "90cea8c6-e1fc-4a53-9a62-fbb951d13dc3", "name": "c35e4979-a43e-4803-a90a-5d57dbc220f7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "75af38b7-bb56-4c47-8f76-f921a8286af9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "547c1fb1-1e21-43de-9124-e75a72e23d31"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6a9f4749-ed1a-46fc-8dfa-46c60b940f65"}}}]}, {"uuid": "92d8cb69-f945-46f1-8d83-82c2569dbeb0", "name": "load_p1rlv18169", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c1eac45-623a-4f0a-874d-a4b56a8e2ea7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "90cea8c6-e1fc-4a53-9a62-fbb951d13dc3"}}}}, {"uuid": "75109933-e360-431a-ae56-6a8713fb4e4f", "name": "0c352d6e-62c5-4ca5-aa5f-694c59a9bde2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7765583938143562, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2953468263898592, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "52932e4b-3f68-4d39-9cdf-6831b48e90a2", "name": "0c352d6e-62c5-4ca5-aa5f-694c59a9bde2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7765583938143562, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2953468263898592, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ce695ebd-ff35-4c4e-8193-4b63fcbae6ad", "name": "0c352d6e-62c5-4ca5-aa5f-694c59a9bde2_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7765583938143562, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2953468263898592, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fa9731e1-8866-4fab-8d71-5c264f3aa4a3", "name": "ceabf2fd-a4fe-49a3-b040-998bc449584e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "75109933-e360-431a-ae56-6a8713fb4e4f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "52932e4b-3f68-4d39-9cdf-6831b48e90a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ce695ebd-ff35-4c4e-8193-4b63fcbae6ad"}}}]}, {"uuid": "7a8af673-1f29-42b4-bdc1-b854078775d7", "name": "load_p1rlv18194", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "949f4cce-f321-4bf0-830b-489edc9964c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fa9731e1-8866-4fab-8d71-5c264f3aa4a3"}}}}, {"uuid": "9387af20-49dd-475f-8324-8380a627105a", "name": "f3505cd8-102f-4866-a8e6-83220722e696_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3791309816618758, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4243669985282459, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "68b9e4ad-9706-461f-a964-bdf6fbec6b39", "name": "f3505cd8-102f-4866-a8e6-83220722e696_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3791309816618758, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4243669985282459, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5767b6a3-e20f-4fb6-b4e9-f280bf9623f1", "name": "f3505cd8-102f-4866-a8e6-83220722e696_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3791309816618758, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4243669985282459, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c78d81df-08be-4abd-8543-ba1e3bc71ced", "name": "540ed8e3-c387-4cc6-a726-b7aa52ff1f02", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9387af20-49dd-475f-8324-8380a627105a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "68b9e4ad-9706-461f-a964-bdf6fbec6b39"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5767b6a3-e20f-4fb6-b4e9-f280bf9623f1"}}}]}, {"uuid": "92845255-cba9-4f50-9388-b5806893844f", "name": "load_p1rlv18201", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ead37cb8-af1e-4a46-9466-6ff298b7f8b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c78d81df-08be-4abd-8543-ba1e3bc71ced"}}}}, {"uuid": "66e107e0-5a8d-442d-af88-d909e6806c1d", "name": "cfed4f37-a7eb-470e-9e6e-7429c56af142_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.969330641054165, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5731466084062546, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "788ad97c-109f-4389-8ab7-e5d1aa18711d", "name": "cfed4f37-a7eb-470e-9e6e-7429c56af142_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.969330641054165, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5731466084062546, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1a1efbec-cf76-4c1f-b9d1-8e1f4f40f85f", "name": "cfed4f37-a7eb-470e-9e6e-7429c56af142_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.969330641054165, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5731466084062546, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eb130b96-b1a6-4ad9-92bb-f7c950649d87", "name": "bb4f4ca4-46cc-4d38-974c-bdc47816551a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "66e107e0-5a8d-442d-af88-d909e6806c1d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "788ad97c-109f-4389-8ab7-e5d1aa18711d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1a1efbec-cf76-4c1f-b9d1-8e1f4f40f85f"}}}]}, {"uuid": "1d20a067-0c6f-4dd1-96ae-00fbe68df8be", "name": "load_p1rlv20414", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0a92e79-0ca2-4a10-9050-9e8d7442b019"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eb130b96-b1a6-4ad9-92bb-f7c950649d87"}}}}, {"uuid": "c3167d2e-7abd-4ec9-b7db-189aa1ce6350", "name": "d7a5cbb2-952d-451b-a9c5-797b0d94e7f3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.231046440619022, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3410918425021952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82f1e837-f7ff-45a7-99cd-9947a49f530b", "name": "d7a5cbb2-952d-451b-a9c5-797b0d94e7f3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.231046440619022, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3410918425021952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b62f9ca8-ad3c-458e-8c6c-329a36d278d6", "name": "d7a5cbb2-952d-451b-a9c5-797b0d94e7f3_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.231046440619022, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3410918425021952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "80fd6578-bbee-4566-9069-5278cad9984b", "name": "d76b08ad-4f91-4cda-9fc7-106a67597cb1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c3167d2e-7abd-4ec9-b7db-189aa1ce6350"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "82f1e837-f7ff-45a7-99cd-9947a49f530b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b62f9ca8-ad3c-458e-8c6c-329a36d278d6"}}}]}, {"uuid": "0f1e4fed-f27c-407f-bb1b-0a713223b7c4", "name": "load_p1rlv20501", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cebe1b53-cca6-4bd4-a9f0-616ffb9750b3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "80fd6578-bbee-4566-9069-5278cad9984b"}}}}, {"uuid": "d452202d-9209-43e3-9f1b-676ca771bf58", "name": "b438d550-9204-4deb-b624-2af3f3f95abf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.718035027374153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.747804250682338, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e61ddcce-02b6-49db-8ac0-51d03bffec33", "name": "153d6d88-fe56-4daa-8fe9-2cc8ef339106", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d452202d-9209-43e3-9f1b-676ca771bf58"}}}]}, {"uuid": "742d6d8b-18ae-42cc-9249-c8f8e8f4f378", "name": "load_p1rlv183_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3df778b4-e60b-4e17-b24b-67742d090f42"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e61ddcce-02b6-49db-8ac0-51d03bffec33"}}}}, {"uuid": "50a6d660-3a31-481e-a6c6-f9690dbb7ca1", "name": "ea228642-f5c5-468e-a9dd-409a56d9f874_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.718035027374153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.747804250682338, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8bda7891-b82b-426f-b18c-5eb0fb925fd2", "name": "10d93e0c-b904-4504-aacd-b5f5838c6695", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "50a6d660-3a31-481e-a6c6-f9690dbb7ca1"}}}]}, {"uuid": "48054bdd-5552-4b5b-be40-7d539c24e9dd", "name": "load_p1rlv183_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3df778b4-e60b-4e17-b24b-67742d090f42"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8bda7891-b82b-426f-b18c-5eb0fb925fd2"}}}}, {"uuid": "c2546b6f-fccd-47a4-b41a-52ade98419c7", "name": "a75381a0-7cd8-4979-84c6-33a9b055fcfa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.127855103696037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.9003395103499228, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4e801885-fc8b-44e6-8cff-8ca4ce49e685", "name": "4d068117-da86-4eb2-98b5-8795e125680a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c2546b6f-fccd-47a4-b41a-52ade98419c7"}}}]}, {"uuid": "c8e3ab78-fc66-4999-a4a3-9f6f6034ea51", "name": "load_p1rlv184_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42ca8327-5dcc-415a-820c-ef6ec038b3d8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4e801885-fc8b-44e6-8cff-8ca4ce49e685"}}}}, {"uuid": "66861fae-18d4-4b12-89f9-a42a505c43fe", "name": "f1233123-1f28-4f98-a380-9a86a8c78985_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.127855103696037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.9003395103499228, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2c03d88e-748c-47a3-b381-2286aeb0abd2", "name": "6f60df77-8937-41d3-b043-9b28c08007c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "66861fae-18d4-4b12-89f9-a42a505c43fe"}}}]}, {"uuid": "db648879-6a88-469a-b3ad-bab23c777335", "name": "load_p1rlv184_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42ca8327-5dcc-415a-820c-ef6ec038b3d8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2c03d88e-748c-47a3-b381-2286aeb0abd2"}}}}, {"uuid": "344cdbb3-a80c-404d-9261-eab3f95c614f", "name": "9c4438d4-ff81-4106-afbc-33f8775b30ce_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.1997144025033135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.11221312599546865, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "83102fd9-ad7e-4a54-8f3b-de4b3131ce41", "name": "6e16813c-5d8c-4a79-810c-0c69e27021cc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "344cdbb3-a80c-404d-9261-eab3f95c614f"}}}]}, {"uuid": "958e832c-6fa1-49f6-b718-480453e9d335", "name": "load_p1rlv190_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33b6400e-c84e-43cf-b254-99f946e5a308"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "83102fd9-ad7e-4a54-8f3b-de4b3131ce41"}}}}, {"uuid": "51739107-d681-47db-a519-530a5d81e380", "name": "81398e9c-c69f-44f1-ae1f-52bf38236f43_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.1997144025033135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.11221312599546865, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4ce391b4-aef8-4ab8-918f-0b278f46c29c", "name": "e6cd5f06-51c1-4e78-a54c-b363b90f918e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "51739107-d681-47db-a519-530a5d81e380"}}}]}, {"uuid": "f5fc5e6d-4a64-4320-b5f3-efa23416a9d2", "name": "load_p1rlv190_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33b6400e-c84e-43cf-b254-99f946e5a308"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4ce391b4-aef8-4ab8-918f-0b278f46c29c"}}}}, {"uuid": "f9119206-6129-4831-af07-d5ed4b642c85", "name": "e8661d29-1ea4-4741-ad74-bd78340ddd97_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.549201052937441, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.4274432384427707, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "71a46f8f-842d-4937-a801-10ae42b24e5f", "name": "6a3d3aef-865d-46e9-a960-161498a719fe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f9119206-6129-4831-af07-d5ed4b642c85"}}}]}, {"uuid": "81c21836-45b0-4154-82ae-266770c938c2", "name": "load_p1rlv193_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84223c1b-69e4-4ebc-8274-8706bb412780"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "71a46f8f-842d-4937-a801-10ae42b24e5f"}}}}, {"uuid": "58f983e5-4e84-49bc-91b5-e3a89fdfa15b", "name": "c5f60dda-40d2-4501-b095-c3a416842481_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.549201052937441, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.4274432384427707, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "64473a35-4b5a-4b3b-9df1-622a7c2e80f0", "name": "6eb521f5-3493-4631-9d8e-09e4fdf20bb4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58f983e5-4e84-49bc-91b5-e3a89fdfa15b"}}}]}, {"uuid": "30dac874-159f-460d-82b9-04974e73e308", "name": "load_p1rlv193_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84223c1b-69e4-4ebc-8274-8706bb412780"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "64473a35-4b5a-4b3b-9df1-622a7c2e80f0"}}}}, {"uuid": "a628d381-76e4-40cf-bc24-857e04147606", "name": "22ff9d9d-ac24-4905-9832-998eae8c6b4e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.052819039029729, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6406126314043256, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "45fd4d14-39df-4fa4-b612-a444a80083df", "name": "e5b3eba3-131f-4d1b-ac25-750cf0a4f239", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a628d381-76e4-40cf-bc24-857e04147606"}}}]}, {"uuid": "5557aa36-6bc2-494a-8072-27bd794500fb", "name": "load_p1rlv202_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "de2366e4-30da-429a-82b9-c0ef27eeab47"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "45fd4d14-39df-4fa4-b612-a444a80083df"}}}}, {"uuid": "23222d19-9d59-45d2-a78d-58fc93fd5c6a", "name": "73133d72-263e-4d0d-987b-43979afa5ec3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.052819039029729, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6406126314043256, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "18272da0-9eb7-4022-ba19-f26531774504", "name": "51166873-b93f-4926-9e62-57215002bd49", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "23222d19-9d59-45d2-a78d-58fc93fd5c6a"}}}]}, {"uuid": "ce162529-8696-48ac-a532-4fcc622d5dcd", "name": "load_p1rlv202_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "de2366e4-30da-429a-82b9-c0ef27eeab47"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "18272da0-9eb7-4022-ba19-f26531774504"}}}}, {"uuid": "d11e80ed-46b6-44dd-afc2-5a36e25a5ea6", "name": "7b83fc9d-61ee-4397-8667-a8588c3bc7c9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 10.312489622510887, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5278845211341558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "86764a50-118f-4ae0-904c-3eb7d9149897", "name": "a56124cc-b228-47df-b16e-25063ca6be04", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d11e80ed-46b6-44dd-afc2-5a36e25a5ea6"}}}]}, {"uuid": "a54e9ee0-d987-4d48-8ca7-d8104322c7c8", "name": "load_p1rlv204_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d663fcdc-6c67-4bc9-99ed-12439f75804f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "86764a50-118f-4ae0-904c-3eb7d9149897"}}}}, {"uuid": "57c0a953-1df6-4ccd-bc63-5a6de34ae501", "name": "48bffe9b-9342-4db0-9ae8-708b0d958dc6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 10.312489622510887, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5278845211341558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "99a56edd-9cc3-431a-8528-a4b629d07122", "name": "c8f70a44-fc85-4b43-84d4-1d98126976c7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "57c0a953-1df6-4ccd-bc63-5a6de34ae501"}}}]}, {"uuid": "f5df41fa-acf8-47b6-87fa-8f483834918a", "name": "load_p1rlv204_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d663fcdc-6c67-4bc9-99ed-12439f75804f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "99a56edd-9cc3-431a-8528-a4b629d07122"}}}}, {"uuid": "63d5acfc-0745-4111-8177-dd66ae09918b", "name": "8d4d1bae-d8e2-4947-998e-f570b1a6b343_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9264329962341185, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3633013910451994, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "54707afb-12f1-4423-950c-81e7e8b8cb3d", "name": "461691a0-b77c-4154-a045-49dcb5767ddc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "63d5acfc-0745-4111-8177-dd66ae09918b"}}}]}, {"uuid": "0db73d3b-1367-4883-92fb-b35b5fe61489", "name": "load_p1rlv206_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90aa0d14-285a-4468-bbde-8d76f65b1780"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "54707afb-12f1-4423-950c-81e7e8b8cb3d"}}}}, {"uuid": "cafb2fa3-b0e4-42e8-b518-09654adfe279", "name": "0cfa0843-e053-415d-9e17-f093387d41dc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9264329962341185, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3633013910451994, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9f52038c-27b1-4970-ae57-228257c9bf35", "name": "76c3855d-0b8d-4cb8-9027-5eb6091bd9a4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cafb2fa3-b0e4-42e8-b518-09654adfe279"}}}]}, {"uuid": "ab252666-2ea9-4e1c-aa7a-e49d13cad5fe", "name": "load_p1rlv206_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90aa0d14-285a-4468-bbde-8d76f65b1780"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9f52038c-27b1-4970-ae57-228257c9bf35"}}}}, {"uuid": "0e86c524-7124-441d-8f10-66f45ed36a68", "name": "8ba30a99-87f5-446e-ace9-b55d7af9360b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.495920496244223, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.518490967551786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "239be45a-d09b-44fb-9a2b-b33b6edd3876", "name": "6e0cfa39-9b52-47ac-87fe-e50f8b5afb6c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0e86c524-7124-441d-8f10-66f45ed36a68"}}}]}, {"uuid": "dadd83f6-5ccf-4bac-ab6f-cae797485027", "name": "load_p1rlv207_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6627102c-4524-4e69-bb4d-5b93226df412"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "239be45a-d09b-44fb-9a2b-b33b6edd3876"}}}}, {"uuid": "9ab22791-181c-4d6f-9cc0-3b61593d3e1d", "name": "ffba4d1d-3ac4-4596-8520-a1ba07ae099e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.495920496244223, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.518490967551786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b22fe0e0-baee-4fe0-b605-ddd37c2ffc6a", "name": "4c32cfe6-8a80-42a6-8417-c3d18f08fcac", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9ab22791-181c-4d6f-9cc0-3b61593d3e1d"}}}]}, {"uuid": "4775bbae-5798-4601-a801-b706bf2c4ee6", "name": "load_p1rlv207_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6627102c-4524-4e69-bb4d-5b93226df412"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b22fe0e0-baee-4fe0-b605-ddd37c2ffc6a"}}}}, {"uuid": "cbc3c1e0-4de2-487d-9596-35203ed448d3", "name": "7f5018a1-d799-4607-bdb7-1808ad52c298_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.1298927880171155, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3569806362972607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eb992e66-c752-4374-a1e0-6b6209cd65af", "name": "f42b3cc4-474a-4489-9d4b-4eec13d43e4b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cbc3c1e0-4de2-487d-9596-35203ed448d3"}}}]}, {"uuid": "925eea4e-1656-49bf-8ff1-d56eb17907ab", "name": "load_p1rlv212_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a982feac-5730-4fe0-a1b8-25c06b36e3b0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eb992e66-c752-4374-a1e0-6b6209cd65af"}}}}, {"uuid": "4154954c-7a18-456b-8622-52f9c2893e7c", "name": "69490a8c-b272-46ef-a77f-31b698c067c7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.1298927880171155, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3569806362972607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f0618bd8-742f-4511-a715-4b51b8f630cb", "name": "90e2596a-5f5a-4214-bd68-9ceaea0de7cf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4154954c-7a18-456b-8622-52f9c2893e7c"}}}]}, {"uuid": "82788e05-b8cc-4374-b70a-1b283d49b619", "name": "load_p1rlv212_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a982feac-5730-4fe0-a1b8-25c06b36e3b0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f0618bd8-742f-4511-a715-4b51b8f630cb"}}}}, {"uuid": "d0f61b3d-9dd8-45cc-b426-9ef0aaac7c1b", "name": "d7e028a1-2a14-4d50-8030-c93bc7628a90_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.583696505537418, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4678810835686954, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "25f54090-d0d6-42d4-b9aa-0b3231c4361b", "name": "082a6d0f-4854-44e3-9719-141d16201519", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d0f61b3d-9dd8-45cc-b426-9ef0aaac7c1b"}}}]}, {"uuid": "0720a126-2cc3-4dc6-af38-58177f078903", "name": "load_p1rlv12687_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "163c3824-6847-4b94-9e81-08f15f4667a1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "25f54090-d0d6-42d4-b9aa-0b3231c4361b"}}}}, {"uuid": "4a209186-c2ca-47e3-91c2-43756ee9d9d1", "name": "eb25abe8-65f1-4081-a59a-54ed4be1f40b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.583696505537418, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4678810835686954, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5df58dd4-8b5e-4767-8d0b-014a76f208cc", "name": "0c67fd09-9f70-4278-b5c3-87ba4c32d4a4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4a209186-c2ca-47e3-91c2-43756ee9d9d1"}}}]}, {"uuid": "587b7bd5-45c9-4d29-a103-1654b7609e31", "name": "load_p1rlv12687_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "163c3824-6847-4b94-9e81-08f15f4667a1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5df58dd4-8b5e-4767-8d0b-014a76f208cc"}}}}, {"uuid": "7c9572f6-3d24-49ce-8e4b-bd40d675d2ff", "name": "24658cf7-3b72-4072-aa99-2aa43e79f68e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.073647835052278, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9870900939844905, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "78dc3bd2-faee-4bfa-a8ad-e73cef6d4bb8", "name": "10dbcd6c-c7d5-4021-8409-dbecd8397b67", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7c9572f6-3d24-49ce-8e4b-bd40d675d2ff"}}}]}, {"uuid": "acd5ef5c-b674-4b1a-bb31-a05b03cac46d", "name": "load_p1rlv12713_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff16aad0-98c1-4563-a844-e0ce909c1a79"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "78dc3bd2-faee-4bfa-a8ad-e73cef6d4bb8"}}}}, {"uuid": "6c8c64d5-8232-48f3-b779-e284a0d79625", "name": "2e710491-6935-4c22-a3fb-03a66154e627_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.073647835052278, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9870900939844905, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f197177b-277e-4088-b0ad-e2d741d93d9f", "name": "b7ff3a42-4e19-4355-b425-f3c12537a70e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c8c64d5-8232-48f3-b779-e284a0d79625"}}}]}, {"uuid": "3f3a20a9-a720-4b31-a158-a8d5a99ac7c5", "name": "load_p1rlv12713_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff16aad0-98c1-4563-a844-e0ce909c1a79"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f197177b-277e-4088-b0ad-e2d741d93d9f"}}}}, {"uuid": "f165255b-c573-44e3-84cd-49783a88ab2e", "name": "1dbad6e5-8c1a-4011-bea1-bff55d509e1c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.717517070184915, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6715744239051029, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "420a0bce-f51c-4b62-8e6b-9a387e86a735", "name": "b4b542a3-23bc-49fe-8b97-9061f3eb79d0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f165255b-c573-44e3-84cd-49783a88ab2e"}}}]}, {"uuid": "18ffffa2-9edd-4b1e-9e65-5b6c6bae3648", "name": "load_p1rlv17006_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b53edd15-5a3e-4b7a-97c4-046582bb4801"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "420a0bce-f51c-4b62-8e6b-9a387e86a735"}}}}, {"uuid": "3a246336-b14b-440f-bc6a-b422db5dbaf9", "name": "eb6052a5-cda9-4e21-bc34-c012cb2a45c9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.717517070184915, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6715744239051029, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "daf286f3-ba08-4a4a-a63b-e2444b88c23b", "name": "34263f6f-fb33-4385-b0da-d5e94b1c7962", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3a246336-b14b-440f-bc6a-b422db5dbaf9"}}}]}, {"uuid": "60052a5b-71bb-4bc8-8e08-ce9093d39625", "name": "load_p1rlv17006_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b53edd15-5a3e-4b7a-97c4-046582bb4801"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "daf286f3-ba08-4a4a-a63b-e2444b88c23b"}}}}, {"uuid": "7b15de94-09be-4c5d-bcad-51da9006d9b8", "name": "4e35b209-fd6d-4c40-8295-c4c03decf7ed_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.232057012168481, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2513317849586886, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a0b81f47-b2c7-481f-b0d6-0a682a1f9e12", "name": "1cd07c6b-4cb5-4c8c-894d-049edc6327bf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b15de94-09be-4c5d-bcad-51da9006d9b8"}}}]}, {"uuid": "062e62cb-fef0-435f-8624-d1ce4dce2226", "name": "load_p1rlv17103_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ff9eb4c-2523-48e0-8490-619d26b9cca4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a0b81f47-b2c7-481f-b0d6-0a682a1f9e12"}}}}, {"uuid": "cf5c4bd5-036b-40d7-b817-cc747db47804", "name": "3052e4cd-e42c-46e4-a14f-22b6800c7106_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.232057012168481, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2513317849586886, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fa3a0152-406c-41d9-823e-8e9d0c488cb3", "name": "7de8fa38-01f0-48ce-bd95-b70f4741c401", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cf5c4bd5-036b-40d7-b817-cc747db47804"}}}]}, {"uuid": "97bbad00-72ba-4f7f-9c82-ae75e91ccf17", "name": "load_p1rlv17103_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ff9eb4c-2523-48e0-8490-619d26b9cca4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fa3a0152-406c-41d9-823e-8e9d0c488cb3"}}}}, {"uuid": "41fbaba5-530d-45c4-8ac2-003cdc444c4b", "name": "2e037faf-fd59-47a0-b8d8-baff8428d902_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2219087879829873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3595087789107823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c00fb412-46d2-4e3b-b892-4c29ed9a96dc", "name": "34327e4c-a3bf-4a34-bb48-d1805c4c2b46", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "41fbaba5-530d-45c4-8ac2-003cdc444c4b"}}}]}, {"uuid": "94e1ce9a-0ea6-41c7-8acd-3c47597808c8", "name": "load_p1rlv17155_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3c6c52e-cf93-467a-a303-94b96b33a3da"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c00fb412-46d2-4e3b-b892-4c29ed9a96dc"}}}}, {"uuid": "bcd3781d-68d3-49c8-98f2-5d2dfd72d02c", "name": "c24d5d86-507c-4da1-a740-cbfa6e9b70d8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2219087879829873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3595087789107823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "367d3fb3-38e1-46a9-afe8-6002ec634b34", "name": "096662e5-09d2-4d3f-83b8-7e5c0313d32b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bcd3781d-68d3-49c8-98f2-5d2dfd72d02c"}}}]}, {"uuid": "ea2204e5-c733-4c5d-9f57-f1ae7993930e", "name": "load_p1rlv17155_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3c6c52e-cf93-467a-a303-94b96b33a3da"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "367d3fb3-38e1-46a9-afe8-6002ec634b34"}}}}, {"uuid": "5ca29a6b-8871-4316-9614-9cdc26b525c3", "name": "b34ee401-7b3b-4bd1-aecd-b49dc4a423cd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.942829069048031, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.025560880160820944, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "28234f8d-0f72-4591-a0e5-92555cccad67", "name": "26114456-b716-42bd-b5cd-0cb881ca3c1e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5ca29a6b-8871-4316-9614-9cdc26b525c3"}}}]}, {"uuid": "3788a4d6-fb67-408b-a39a-382a54c99337", "name": "load_p1rlv17164_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "041caa30-2985-44ca-8013-e11a9bda7dff"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "28234f8d-0f72-4591-a0e5-92555cccad67"}}}}, {"uuid": "d1180f7a-4072-4682-9e72-f7710c39e782", "name": "1c5d76ca-3c9e-4297-a20f-bd64dbf176a2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.942829069048031, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.025560880160820944, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "62763e78-f998-4c71-9591-66a454e2912d", "name": "3d73307b-f167-4794-a374-6943ca16307f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d1180f7a-4072-4682-9e72-f7710c39e782"}}}]}, {"uuid": "607dd42d-074f-451c-abe2-2be23e589cec", "name": "load_p1rlv17164_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "041caa30-2985-44ca-8013-e11a9bda7dff"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "62763e78-f998-4c71-9591-66a454e2912d"}}}}, {"uuid": "21a8d94a-5f88-43e9-86ad-5de85cc4c1bc", "name": "d6f25302-9bf5-4b6b-8109-772358bb7981_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.232057012168481, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2513317849586886, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d8ce9ad7-c027-48cb-8677-3e76b8508613", "name": "fc57ffc1-a1a5-4772-ab6c-285ce5f0b9be", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "21a8d94a-5f88-43e9-86ad-5de85cc4c1bc"}}}]}, {"uuid": "921af739-3a49-488e-b908-a755178667b5", "name": "load_p1rlv17167_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b4e44ab-e644-4e48-b1b2-82dc15d38d17"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d8ce9ad7-c027-48cb-8677-3e76b8508613"}}}}, {"uuid": "c95623eb-7e70-4230-89ec-95912a3b104e", "name": "870b8ada-fd08-4206-9fc5-01346c9ff362_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.232057012168481, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2513317849586886, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1ce786d2-8a25-4b49-a086-d96fa76a8d08", "name": "d75ae0f2-7d95-4690-b229-56fce3ab59ee", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c95623eb-7e70-4230-89ec-95912a3b104e"}}}]}, {"uuid": "b4f5139d-e8a9-4b09-81cc-226782639deb", "name": "load_p1rlv17167_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b4e44ab-e644-4e48-b1b2-82dc15d38d17"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1ce786d2-8a25-4b49-a086-d96fa76a8d08"}}}}, {"uuid": "7446423d-82b3-4d10-bcf9-723674add925", "name": "d3372449-16d8-484a-a833-f29fb227400d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9560799536695528, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.499516661128582, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6819cfd1-4ede-49bb-80b3-81faba8c4337", "name": "26394e59-96de-4fcd-bdf3-b8c99b381804", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7446423d-82b3-4d10-bcf9-723674add925"}}}]}, {"uuid": "a26b6799-9da9-46b0-974d-186fa2a110ef", "name": "load_p1rlv17199_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5768eaca-abe3-4347-af78-02b50ec6f2a9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6819cfd1-4ede-49bb-80b3-81faba8c4337"}}}}, {"uuid": "aec4bb52-4e0e-4666-b311-aff796a6e741", "name": "9fd2156c-d0a8-4aeb-a216-5711fc5b8345_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9560799536695528, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.499516661128582, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6bbfcac3-e8d6-49b5-b0ed-56f508d367d2", "name": "0504995a-08d3-4acf-a5ec-f035fb0edd55", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aec4bb52-4e0e-4666-b311-aff796a6e741"}}}]}, {"uuid": "f16ea12a-d96f-4c89-aae1-a9e2f73b498e", "name": "load_p1rlv17199_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5768eaca-abe3-4347-af78-02b50ec6f2a9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6bbfcac3-e8d6-49b5-b0ed-56f508d367d2"}}}}, {"uuid": "9501db4f-4d34-46ab-b337-a9b58a0ecc04", "name": "c7920de9-9700-44da-88a2-baee1b71a3fa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4651344294517608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7736313908316925, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3e397dca-c5aa-41b9-a651-a5594d57ce82", "name": "b3217784-6b6f-4cbb-ae04-0586946430b3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9501db4f-4d34-46ab-b337-a9b58a0ecc04"}}}]}, {"uuid": "486b1fa9-c97d-4d8f-8dd5-a12f4ed1f6a4", "name": "load_p1rlv17376_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c9970ae-e914-407d-8222-12c08638a854"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3e397dca-c5aa-41b9-a651-a5594d57ce82"}}}}, {"uuid": "d1c9d7de-ec26-4339-b074-a8feed5b6bd3", "name": "b9ef11a0-e24d-411d-9d2d-b1d7f910cbf7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4651344294517608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7736313908316925, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3f324903-fa8c-4c76-a937-15d2f343d5e4", "name": "365eec18-9d98-4ef6-a549-3c01f3c032ad", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d1c9d7de-ec26-4339-b074-a8feed5b6bd3"}}}]}, {"uuid": "e074293a-eec0-4036-a797-8b60e105c83f", "name": "load_p1rlv17376_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c9970ae-e914-407d-8222-12c08638a854"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3f324903-fa8c-4c76-a937-15d2f343d5e4"}}}}, {"uuid": "ead23219-08fe-44ab-820a-d0d14103563b", "name": "ba31d245-a5df-4e40-bd84-2537388de1de_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f20bbd88-d644-4460-b91b-f7d7a0dd9c33", "name": "e7afd31e-cc94-4190-bd64-93c2978c75e8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ead23219-08fe-44ab-820a-d0d14103563b"}}}]}, {"uuid": "c7830443-55ae-4071-84cd-61cb658dfa1d", "name": "load_p1rlv17402_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc7fa312-1baf-4f23-925f-a281071183a6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f20bbd88-d644-4460-b91b-f7d7a0dd9c33"}}}}, {"uuid": "c032abac-cd1f-4a1e-bbd5-d4802c4799f8", "name": "7aee58e6-4854-4da3-b1b6-cd96d079e46f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d9b0b461-3686-46ed-a372-44fe942df55a", "name": "08b8a5f8-54ac-4bef-9a93-f060a37836e7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c032abac-cd1f-4a1e-bbd5-d4802c4799f8"}}}]}, {"uuid": "c4c2d28d-64de-4aef-9b56-71b581140ea8", "name": "load_p1rlv17402_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc7fa312-1baf-4f23-925f-a281071183a6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d9b0b461-3686-46ed-a372-44fe942df55a"}}}}, {"uuid": "c6d70775-0474-4758-9e2b-53a281b01f2b", "name": "951110b2-1b20-46ea-97ea-669c68971c74_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cece30de-5748-49d0-95c9-04aae051c96b", "name": "934dfe2f-a3da-4353-ab7d-ff5cf4bd4aca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c6d70775-0474-4758-9e2b-53a281b01f2b"}}}]}, {"uuid": "4de72967-d0e0-4245-a2c9-90ed95c634db", "name": "load_p1rlv17413_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f147f7e5-33e8-430b-9822-715e772debb3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cece30de-5748-49d0-95c9-04aae051c96b"}}}}, {"uuid": "410be76a-d3e6-4fe5-8234-da21b56ab803", "name": "86f67b91-abe0-4707-b5b7-1fc268250b03_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a1f185f9-ed32-4e4d-8ab5-4cb30f46e1fa", "name": "be5f5a1e-d7c2-4cc0-b2ec-ebb2f4d99001", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "410be76a-d3e6-4fe5-8234-da21b56ab803"}}}]}, {"uuid": "c17dc359-c1e8-4ac0-b8b5-6f4911806a06", "name": "load_p1rlv17413_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f147f7e5-33e8-430b-9822-715e772debb3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a1f185f9-ed32-4e4d-8ab5-4cb30f46e1fa"}}}}, {"uuid": "2b1560aa-044b-4355-a313-8393ed56e206", "name": "7091f011-29cf-4970-a077-57d16406022c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.892763602300674, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6648734705927571, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4bc73f95-dad0-426c-9936-a29efa07e8e8", "name": "54d54f42-88ad-4e97-8ab7-0abf5a820925", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2b1560aa-044b-4355-a313-8393ed56e206"}}}]}, {"uuid": "bdf7f58c-d310-4d81-a73e-f4b0b1a4ce42", "name": "load_p1rlv18362_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a28b095-45f5-43ec-983b-c1de596d4cb5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4bc73f95-dad0-426c-9936-a29efa07e8e8"}}}}, {"uuid": "257a4574-d5ef-4c96-9b9f-d77e051fafe0", "name": "91b731da-63f3-4bc2-b6e9-af3b83093c8d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.892763602300674, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6648734705927571, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d8380065-441a-43ce-be4c-f8346bb2f521", "name": "2874337f-dfcb-4793-be27-1510b75a005f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "257a4574-d5ef-4c96-9b9f-d77e051fafe0"}}}]}, {"uuid": "d490ecf2-bbea-47c7-acb6-20d2732d4e2e", "name": "load_p1rlv18362_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a28b095-45f5-43ec-983b-c1de596d4cb5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d8380065-441a-43ce-be4c-f8346bb2f521"}}}}, {"uuid": "75ddb8f7-60f7-490b-bf33-5873e706c7bf", "name": "87c379cb-60d1-4d1c-a9cd-99664fa99d1c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6733980323267108, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22626974414284334, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "584dc0fb-4cac-4f30-9134-437168f50f38", "name": "b498951a-0c47-4046-ad51-574662d33fe5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "75ddb8f7-60f7-490b-bf33-5873e706c7bf"}}}]}, {"uuid": "16da4765-2a94-42b2-8fa3-ee4d896e71d7", "name": "load_p1rlv18364_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d1c3d0a-9def-4516-8429-386f1d70f506"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "584dc0fb-4cac-4f30-9134-437168f50f38"}}}}, {"uuid": "92e69644-de04-43d7-b2e1-0e3bd74982eb", "name": "266a88e0-df41-41ca-bfb6-60e12a5941f7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6733980323267108, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22626974414284334, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e9864b39-af63-4922-a8d4-02e847767bcc", "name": "a91ad431-0ff6-4239-b74c-a5d9e3850a5c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "92e69644-de04-43d7-b2e1-0e3bd74982eb"}}}]}, {"uuid": "da244663-5b6a-4fd8-a1f5-ac4badf33a37", "name": "load_p1rlv18364_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d1c3d0a-9def-4516-8429-386f1d70f506"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e9864b39-af63-4922-a8d4-02e847767bcc"}}}}, {"uuid": "a9ddfd1d-3312-40ce-bb2e-0ad14e5534c0", "name": "1952fc3c-5bb1-4426-aedd-3b281fbbcce4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5880239691905954, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.38099900657746644, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4b8ad38a-67e8-44ef-85a8-e7448d462d0f", "name": "66287ea0-a48c-4197-8596-01b7383329a5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a9ddfd1d-3312-40ce-bb2e-0ad14e5534c0"}}}]}, {"uuid": "b9c897cb-86a2-49e9-9eb4-373574153ce3", "name": "load_p1rlv18367_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "408c825d-17ac-4aea-9fc7-fff420657fc7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4b8ad38a-67e8-44ef-85a8-e7448d462d0f"}}}}, {"uuid": "743c8186-d479-45e9-b3bc-a35e639913a6", "name": "5dd5f3e7-b82b-4663-aa29-5f66bf7ec617_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5880239691905954, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.38099900657746644, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "accd5657-d180-46cc-b3f6-078c5d6c4023", "name": "ef824912-fe95-47a6-a947-dc3cd4ae0fe6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "743c8186-d479-45e9-b3bc-a35e639913a6"}}}]}, {"uuid": "2bb645d5-61aa-411d-a6ca-d3858ae387f3", "name": "load_p1rlv18367_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "408c825d-17ac-4aea-9fc7-fff420657fc7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "accd5657-d180-46cc-b3f6-078c5d6c4023"}}}}, {"uuid": "7b1b9654-8f6f-41f8-9949-7c667f121221", "name": "ae93fb7d-8b86-4bc8-8c76-23340af3316e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.287089484997603, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1789824543876289, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "40b0ac72-0e92-4d11-8da5-eac2a4d51459", "name": "a32daa16-e1f3-4307-b131-b623a894e02a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b1b9654-8f6f-41f8-9949-7c667f121221"}}}]}, {"uuid": "188c068c-f0d5-42db-b95f-b14c18ac3ead", "name": "load_p1rlv18370_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905e171c-13d7-4f8d-b88a-7501b2327d81"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "40b0ac72-0e92-4d11-8da5-eac2a4d51459"}}}}, {"uuid": "68317224-66ee-48bc-b78a-da4bb713889f", "name": "e2e5bbaa-022b-4234-992f-0c2ac3cf90a1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.287089484997603, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1789824543876289, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "41fea339-814b-42d1-8c26-64a3fa35ebbe", "name": "18efa5ce-5d1b-485f-9ecc-c872b07928f1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "68317224-66ee-48bc-b78a-da4bb713889f"}}}]}, {"uuid": "9ae409db-c6ba-45ca-9a8a-331455db2e0e", "name": "load_p1rlv18370_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905e171c-13d7-4f8d-b88a-7501b2327d81"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "41fea339-814b-42d1-8c26-64a3fa35ebbe"}}}}, {"uuid": "793805f3-a494-4fa1-a522-74e0ac925749", "name": "dfb5f81d-e24b-45c7-8605-ddb09f7d9eb3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2520868864654517, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.447133871274774, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d5aa70af-2ee7-4b7d-b94f-3ea222b385c2", "name": "125e24fe-6596-4d6d-94db-5dbf4bc5e421", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "793805f3-a494-4fa1-a522-74e0ac925749"}}}]}, {"uuid": "0f43e824-7939-4679-98c8-608f518dd550", "name": "load_p1rlv18371_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58792e8c-3ad9-45bb-ac47-01983cca2a2b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d5aa70af-2ee7-4b7d-b94f-3ea222b385c2"}}}}, {"uuid": "69f19827-944b-4a54-a28e-0dfe9c47b0fc", "name": "390f6dbf-4017-4c8e-bceb-b4bfeb8f2003_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2520868864654517, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.447133871274774, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e70868cc-51f0-42a5-819e-83d4b3dbf361", "name": "931fc67d-b740-4547-9b8b-b33ffdbde5cb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "69f19827-944b-4a54-a28e-0dfe9c47b0fc"}}}]}, {"uuid": "67f1c6b3-83b2-48f1-9099-9b28b64418ad", "name": "load_p1rlv18371_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58792e8c-3ad9-45bb-ac47-01983cca2a2b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e70868cc-51f0-42a5-819e-83d4b3dbf361"}}}}, {"uuid": "b686fa6e-2461-4808-9066-25867f45ba9d", "name": "420e1a0a-ffcb-4581-8b92-d552392c4fee_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8791002615066037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24190904367644575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b9fcde9a-cbbd-4ec9-92f8-ff41efd0cf35", "name": "7c92f79e-4b96-4736-b8a9-6742d7ac1ddb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b686fa6e-2461-4808-9066-25867f45ba9d"}}}]}, {"uuid": "b7724836-8957-44b6-a1ee-1e13527201ca", "name": "load_p1rlv22745_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a86348e4-7573-4903-b223-90155579923e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b9fcde9a-cbbd-4ec9-92f8-ff41efd0cf35"}}}}, {"uuid": "53db9d3b-3c21-40c5-80a9-ef617736c9a8", "name": "5ff251b3-da3d-4586-825b-ac39058ba513_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8791002615066037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24190904367644575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5a8333e2-17ee-4e51-a880-051e78240562", "name": "4aaed0fb-53e6-4c5b-9cab-4e1899e05ed4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "53db9d3b-3c21-40c5-80a9-ef617736c9a8"}}}]}, {"uuid": "85381bbb-b76b-4491-8426-3f1f546557da", "name": "load_p1rlv22745_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a86348e4-7573-4903-b223-90155579923e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5a8333e2-17ee-4e51-a880-051e78240562"}}}}, {"uuid": "2616a540-3729-4d1c-9e19-3e6dd7591c99", "name": "0d546f4b-fb69-4955-892c-71bff61644ad_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4163439957648214, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5697938312046736, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "573e0cb7-9d98-4b90-8399-be6d8152d6aa", "name": "8080e54c-51ef-46b6-b0ec-6207aec4ee3e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2616a540-3729-4d1c-9e19-3e6dd7591c99"}}}]}, {"uuid": "e52b1a47-a419-442d-ad0a-75dd5602f688", "name": "load_p1rlv22758_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db05b7f0-d2a8-4876-876e-ef0e9b469580"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "573e0cb7-9d98-4b90-8399-be6d8152d6aa"}}}}, {"uuid": "6e457b9f-df86-4742-8b47-d0463266fc5c", "name": "f96e1a4f-9a54-4b4c-b072-9ccb0d534841_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4163439957648214, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5697938312046736, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6733e95a-a926-463a-b097-3eadebfffe1b", "name": "f77f6636-5ffb-4446-a8c7-6d920b16449a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6e457b9f-df86-4742-8b47-d0463266fc5c"}}}]}, {"uuid": "462e1f9c-3a5f-4f5b-a281-0d93e7ab513d", "name": "load_p1rlv22758_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db05b7f0-d2a8-4876-876e-ef0e9b469580"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6733e95a-a926-463a-b097-3eadebfffe1b"}}}}, {"uuid": "e4ea7fd7-7dd6-4aa3-b984-f4806c69c9cd", "name": "", "resistance": 0.33831264, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 3, "connection_type": "DELTA", "tap_positions": [1.0, 1.0, 1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 39.838337182448036, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 30000.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "9a9d218f-3818-4abe-9c9f-7fee34acb7cc", "name": "", "resistance": 0.33831264, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 3, "connection_type": "STAR", "tap_positions": [1.03125, 1.03125, 1.03125], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.199769053117783, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 30000.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "0ff22131-b16e-4e2e-808a-862b62584bf5", "name": "5ea8fd3b-2d5b-4c48-84db-0b2934c03576", "pct_no_load_loss": 0.0, "pct_full_load_loss": 0.67662528, "coupling_sequences": [[1, 2]], "winding_reactances": [7.40307669516232], "is_center_tapped": false, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "e4ea7fd7-7dd6-4aa3-b984-f4806c69c9cd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "9a9d218f-3818-4abe-9c9f-7fee34acb7cc"}}}]}, {"uuid": "43f6bef8-6670-432e-967e-238f41116cd3", "name": "", "resistance": 0.266272, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.2, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 25.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "d7f56744-2b80-450f-96df-d394c22746ae", "name": "", "resistance": 0.532544, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 0.12, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 25.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "fc204377-0430-4e39-92d8-12637b9626bd", "name": "c90ce3f4-34f4-43b1-9398-685a67188e1f", "pct_no_load_loss": 0.472, "pct_full_load_loss": 0.798816, "coupling_sequences": [[1, 2], [1, 3], [2, 3]], "winding_reactances": [2.4, 1.6, 2.4], "is_center_tapped": true, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "43f6bef8-6670-432e-967e-238f41116cd3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "d7f56744-2b80-450f-96df-d394c22746ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "d7f56744-2b80-450f-96df-d394c22746ae"}}}]}, {"uuid": "409027f9-8175-46a5-9446-3197e251f48e", "name": "", "resistance": 0.41605, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.2, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 10.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "9482a710-e97e-42d4-9afe-b8a7af1d4dd2", "name": "", "resistance": 0.832101, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 0.12, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 10.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39", "name": "4e1e5ead-0aba-4efa-8a66-7f0837cdfdb3", "pct_no_load_loss": 0.68, "pct_full_load_loss": 1.248151, "coupling_sequences": [[1, 2], [1, 3], [2, 3]], "winding_reactances": [1.08, 0.72, 1.08], "is_center_tapped": true, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "409027f9-8175-46a5-9446-3197e251f48e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "9482a710-e97e-42d4-9afe-b8a7af1d4dd2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "9482a710-e97e-42d4-9afe-b8a7af1d4dd2"}}}]}, {"uuid": "af41736a-6c75-4cfe-a051-04f517ad6634", "name": "", "resistance": 0.16642, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.2, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 75.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "a59da237-5e2b-4026-aa20-285c4f5ac91a", "name": "", "resistance": 0.33284, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 0.12, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 75.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "e2f53d7d-7442-4b42-8617-11656e408189", "name": "7069cfb8-3af7-4776-b0a7-3ee93d0a6d00", "pct_no_load_loss": 0.38, "pct_full_load_loss": 0.49926, "coupling_sequences": [[1, 2], [1, 3], [2, 3]], "winding_reactances": [2.4, 1.6, 2.4], "is_center_tapped": true, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "af41736a-6c75-4cfe-a051-04f517ad6634"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "a59da237-5e2b-4026-aa20-285c4f5ac91a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "a59da237-5e2b-4026-aa20-285c4f5ac91a"}}}]}, {"uuid": "e45fd6cc-f0ba-4fec-a6cc-8de2e6071dd5", "name": "", "resistance": 0.87204, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 3, "connection_type": "STAR", "tap_positions": [1.0, 1.0, 1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.199769053117783, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 75.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "cedafdc8-4789-49a5-b801-1112786f4229", "name": "", "resistance": 0.87204, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 3, "connection_type": "STAR", "tap_positions": [1.0, 1.0, 1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 0.27713625866050806, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 75.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39", "name": "25e347d1-54f4-4401-a111-bc5b034415d8", "pct_no_load_loss": 0.6, "pct_full_load_loss": 1.74408, "coupling_sequences": [[1, 2]], "winding_reactances": [3.24], "is_center_tapped": false, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "e45fd6cc-f0ba-4fec-a6cc-8de2e6071dd5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "cedafdc8-4789-49a5-b801-1112786f4229"}}}]}, {"uuid": "5f0d2c9e-13b8-4f29-8af9-6188720eedac", "name": "", "resistance": 0.199704, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.2, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 50.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "43ae60da-acbb-41be-b1e9-850c4e760ec4", "name": "", "resistance": 0.399408, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 0.12, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 50.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208", "name": "dcf66ff7-2c37-4071-944c-a1a7c55efdd0", "pct_no_load_loss": 0.37, "pct_full_load_loss": 0.599112, "coupling_sequences": [[1, 2], [1, 3], [2, 3]], "winding_reactances": [2.4, 1.6, 2.4], "is_center_tapped": true, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "5f0d2c9e-13b8-4f29-8af9-6188720eedac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "43ae60da-acbb-41be-b1e9-850c4e760ec4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "43ae60da-acbb-41be-b1e9-850c4e760ec4"}}}]}, {"uuid": "a0c12460-ccac-452f-9740-c1574cf5bb1f", "name": "", "resistance": 0.266272, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.2, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 50.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "f6e9a1ac-c88b-4fe2-a154-24f5f7642ecf", "name": "", "resistance": 0.532544, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 0.12, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 50.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "fac52057-f5c2-4934-9fe6-6517159b5db2", "name": "c008ed76-f669-42ff-b5cd-d16b05f9d6a9", "pct_no_load_loss": 0.472, "pct_full_load_loss": 0.798816, "coupling_sequences": [[1, 2], [1, 3], [2, 3]], "winding_reactances": [2.4, 1.6, 2.4], "is_center_tapped": true, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "a0c12460-ccac-452f-9740-c1574cf5bb1f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "f6e9a1ac-c88b-4fe2-a154-24f5f7642ecf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "f6e9a1ac-c88b-4fe2-a154-24f5f7642ecf"}}}]}, {"uuid": "777a7223-aa6f-4f59-8319-64339d066aab", "name": "93ddfc44-8481-4bdf-ab60-e9ff52bb462f", "pct_no_load_loss": 0.37, "pct_full_load_loss": 0.798816, "coupling_sequences": [[1, 2], [1, 3], [2, 3]], "winding_reactances": [2.4, 1.6, 2.4], "is_center_tapped": true, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "a0c12460-ccac-452f-9740-c1574cf5bb1f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "f6e9a1ac-c88b-4fe2-a154-24f5f7642ecf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "f6e9a1ac-c88b-4fe2-a154-24f5f7642ecf"}}}]}, {"uuid": "bd55901d-7c9b-4820-ae8e-57c9ca06328f", "name": "", "resistance": 0.266272, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.2, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 75.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "cd8890eb-9546-4f24-acce-6fcf2ee84c86", "name": "", "resistance": 0.532544, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 0.12, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 75.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "5b183af9-59bd-450e-bea6-e545db99accd", "name": "9d1848f6-5882-41b9-b2a8-c82d69262c5d", "pct_no_load_loss": 0.37, "pct_full_load_loss": 0.798816, "coupling_sequences": [[1, 2], [1, 3], [2, 3]], "winding_reactances": [2.4, 1.6, 2.4], "is_center_tapped": true, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "bd55901d-7c9b-4820-ae8e-57c9ca06328f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "cd8890eb-9546-4f24-acce-6fcf2ee84c86"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "cd8890eb-9546-4f24-acce-6fcf2ee84c86"}}}]}, {"uuid": "d7f8bb16-2fa2-44b9-9ef9-402d0cdb4de0", "name": "", "resistance": 0.41605, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.2, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 25.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "13913f15-8cf3-4455-991c-233f79168c29", "name": "", "resistance": 0.832101, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 0.12, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 25.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "7ecefea9-516a-4cb1-8c06-cac3a09bcc5e", "name": "c3e09961-f803-4e36-b0bb-ca80f2402057", "pct_no_load_loss": 0.68, "pct_full_load_loss": 1.248151, "coupling_sequences": [[1, 2], [1, 3], [2, 3]], "winding_reactances": [1.08, 0.72, 1.08], "is_center_tapped": true, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "d7f8bb16-2fa2-44b9-9ef9-402d0cdb4de0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "13913f15-8cf3-4455-991c-233f79168c29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "13913f15-8cf3-4455-991c-233f79168c29"}}}]}, {"uuid": "cb14ae0e-2eb0-4352-9990-bab8587ecbc3", "name": "sb10_p1rhs7_1247_trans_301", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16bb904e-b153-4b0a-97f5-53ad7c6606d8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "001adbd4-6616-4dce-83d2-025e896ada51"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0ff22131-b16e-4e2e-808a-862b62584bf5"}}}}, {"uuid": "0f8211a9-3a1c-4289-91ed-70595408cdb6", "name": "tr(r:p1rdt4964-p1rdt4964lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7f13598-e628-457c-9ba6-d9a0123e882c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3541a1a-9680-4baf-9b87-a1322cb1a16a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3541a1a-9680-4baf-9b87-a1322cb1a16a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "4459a649-5f2a-49a5-ad44-234e0a27c101", "name": "tr(r:p1rdt4980-p1rdt4980lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ddb0629-4947-47ca-83f9-9b7c073db235"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab731358-e17f-4c48-b6f8-c7bb4c7701de"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab731358-e17f-4c48-b6f8-c7bb4c7701de"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "a14eb44e-8274-4874-9188-51fccadf71e2", "name": "tr(r:p1rdt5017-p1rdt5017lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c09f718-9379-4281-86f6-55c46e46aec6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0375d197-ccd2-4ed8-9439-857b700cefb8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0375d197-ccd2-4ed8-9439-857b700cefb8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f59e21f9-fe45-41c0-9dfb-d93eeb5c5a9b", "name": "tr(r:p1rdt5126-p1rdt5126lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0dafde2-c08e-4624-9212-e0fea9e47c2c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e33e473-8d5b-4704-bdab-56032991f94e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e33e473-8d5b-4704-bdab-56032991f94e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "a224a322-e724-45d6-b4de-232506f9f06e", "name": "tr(r:p1rdt5140-p1rdt5140lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b0fd055-d0ac-4678-a8e5-679e12741736"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f114a56-98d7-4fe8-b0b1-b8c4bc791cf9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f114a56-98d7-4fe8-b0b1-b8c4bc791cf9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "8d206fac-69f4-4fad-9199-94c1209314a0", "name": "tr(r:p1rdt5142-p1rdt5142lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d579047b-82f6-49bf-bd7b-28c818d44bb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e071635-4071-470d-be09-4484cb90441a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e071635-4071-470d-be09-4484cb90441a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "316c1908-f8c8-4724-99c8-68acd6ca28e6", "name": "tr(r:p1rdt5153-p1rdt5153lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb8dae66-287a-4b8a-9cda-6ae02cb8f8a9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ec20ad2-b04f-43fc-ad8d-d41746549a57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ec20ad2-b04f-43fc-ad8d-d41746549a57"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "f6e301fe-1473-4823-8abc-5bb307b2ce1a", "name": "tr(r:p1rdt5154-p1rdt5154lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50332aed-ecfd-465a-977e-c24ed6462860"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9750085f-4afd-48ee-89f3-edbe9687b242"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "5e034209-8f4d-4112-bf2e-fc5d831d0b41", "name": "tr(r:p1rdt5155-p1rdt5155lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16712e10-4c7f-428b-917b-135ab3c2d4b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85351f49-cb19-4f71-a6ae-a21f5a48af6f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85351f49-cb19-4f71-a6ae-a21f5a48af6f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "5a444dd7-7ccc-4ad8-bdb1-e278ecb6ab5b", "name": "tr(r:p1rdt5159-p1rdt5159lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90fb2270-4759-4779-80c1-7f93d66e1c53"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba7e3a6b-f62f-432f-afe7-2ebbfc9abd59"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba7e3a6b-f62f-432f-afe7-2ebbfc9abd59"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "224f6b7f-ed33-4683-96f3-f5463456d1f4", "name": "tr(r:p1rdt5172-p1rdt5172lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ea481f8-b9c7-4067-9bfb-4f7cdc5dee15"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48efdcb9-083c-4e17-a1d2-acb1388f085e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48efdcb9-083c-4e17-a1d2-acb1388f085e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d096b871-d8cf-49e3-a9d8-bce4ee870d37", "name": "tr(r:p1rdt5179-p1rdt5179lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d22f1247-b756-4498-8cf8-fef7d1e859ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd4155b2-ca55-41d7-bd35-98a5eec8c39a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd4155b2-ca55-41d7-bd35-98a5eec8c39a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "03f5affd-877c-44f3-a574-df7d0a34d7bf", "name": "tr(r:p1rdt5180-p1rdt5180lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6316fa2-dd57-46d4-89c0-f11dd675d686"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae26acb3-c2c9-479c-9d19-c30bf00aa8c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae26acb3-c2c9-479c-9d19-c30bf00aa8c5"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "1b56638f-139e-4db8-93ee-87c32a4330ef", "name": "tr(r:p1rdt5183-p1rdt5183lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23f0bb81-3c30-45a5-89ca-2011e3881ddb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bbde2e8-42c0-486b-9759-78898d177f93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bbde2e8-42c0-486b-9759-78898d177f93"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4d397307-5f03-484b-bb97-2343016c603d", "name": "tr(r:p1rdt5184-p1rdt5184lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "431b672b-cb45-4294-b1f9-1d63f4efc8db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1656cc28-8a5b-40da-887f-25605dd336aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1656cc28-8a5b-40da-887f-25605dd336aa"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "7cee3b1b-3e70-4066-ae18-13419331a26b", "name": "tr(r:p1rdt5195-p1rdt5195lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58c6d858-d457-4fe6-a45b-b9b2b73cad8c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf05c1bb-39cc-48b3-a576-18913e0cff13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf05c1bb-39cc-48b3-a576-18913e0cff13"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "39039b81-4e2f-42c7-b890-1bf3d089058a", "name": "tr(r:p1rdt5200-p1rdt5200lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "799ab435-c0a4-4515-8125-e8ca2fb7632d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "03e7bfdb-ff8b-4142-95ef-8d848ff5d2db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "03e7bfdb-ff8b-4142-95ef-8d848ff5d2db"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "02b53edb-2e1f-4263-9d58-d6f7837fee8b", "name": "tr(r:p1rdt5201-p1rdt5201lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c289632-ba52-4b65-b6da-ac76b1477246"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8162a8c-5339-4f42-bd7a-b6dbc5ff463b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8162a8c-5339-4f42-bd7a-b6dbc5ff463b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "403188b7-0c92-46b1-b0a0-72798d290fa2", "name": "tr(r:p1rdt5202-p1rdt5202lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97e4f179-9d60-4183-8326-eb0ab98a53eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "39eaedd7-75b6-449f-8ff6-6e31f6e74504"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "39eaedd7-75b6-449f-8ff6-6e31f6e74504"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b875dd86-44ae-41fc-b621-1d50fd1369ab", "name": "tr(r:p1rdt5206-p1rdt5206lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ed081eb-6b56-43b8-9cf8-e7ffdd8222f2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "599a2995-33d5-4bcc-8cd3-585ea37577cd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "599a2995-33d5-4bcc-8cd3-585ea37577cd"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "cfd7929a-5a92-40d0-8117-68f69e67d917", "name": "tr(r:p1rdt5218-p1rdt5218lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dda7f7c-3b21-46a0-88a3-2b7f028b7772"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c650eda9-132b-4419-a055-ad68037c7772"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c650eda9-132b-4419-a055-ad68037c7772"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "e226528d-6510-43cc-9946-faedc99958f7", "name": "tr(r:p1rdt5236-p1rdt5236lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22db53ea-6d9a-4527-9b36-34a4bcd2c74f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f252d81-66ee-40a6-bce7-2891e06b39e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f252d81-66ee-40a6-bce7-2891e06b39e4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "897a5ce1-914d-454b-a71c-5980ff30cc2f", "name": "tr(r:p1rdt5342-p1rdt5342lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c8f9ea6-06fb-4fd0-8629-ceea4f32189f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e01069aa-388b-4362-9d02-a164f173dc20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e01069aa-388b-4362-9d02-a164f173dc20"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "519868f4-b58e-4fdc-b749-5324585674fa", "name": "tr(r:p1rdt5472-p1rdt5472lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a8c3f7f-b9be-4c5e-b6f0-8f2fc18935fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34a1276e-c702-4c69-b7b1-566d400da2de"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34a1276e-c702-4c69-b7b1-566d400da2de"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "3afcd18e-c615-4125-9695-1bf38cf70f51", "name": "tr(r:p1rdt5475-p1rdt5475lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b9e57e0-6dc8-4831-ac7d-36f8608b7a8d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d181674-9355-488b-8a3f-5b7c844c35a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d181674-9355-488b-8a3f-5b7c844c35a5"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "5cd3e55d-3396-480b-b9cd-00b92b563c79", "name": "tr(r:p1rdt5476-p1rdt5476lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b077dc9c-1c6f-4403-ae0c-954e7cc0c692"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0888f4c5-e037-4891-99fb-fd43934ffae0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0888f4c5-e037-4891-99fb-fd43934ffae0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "38e532e3-559a-4907-853d-7cd08b7d5493", "name": "tr(r:p1rdt5477-p1rdt5477lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7d7f462-1ab5-4fd8-baaa-7e576eead5c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fafd64c3-efe5-4684-b06f-44e4c8555aa4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fafd64c3-efe5-4684-b06f-44e4c8555aa4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "473cf7e7-cc10-4402-a7d2-42b4288be59b", "name": "tr(r:p1rdt5478-p1rdt5478lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a97491e-2c98-4584-9b74-5593f17faeda"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5107bc9c-f463-49f6-a92f-23c5730475e2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5107bc9c-f463-49f6-a92f-23c5730475e2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "f3d168ab-98b0-4f71-a258-4db4b923422f", "name": "tr(r:p1rdt5480-p1rdt5480lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2568f11c-8a37-4a55-8bce-9f0d56ac386a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44ac9e38-8ae3-4102-822b-1c638a6c878a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44ac9e38-8ae3-4102-822b-1c638a6c878a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6ab40212-5945-4e0d-be6c-547813180165", "name": "tr(r:p1rdt5481-p1rdt5481lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d29d8b74-a24d-4474-9752-c1ffa1aa7f7c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f213ee9e-6ae7-4e82-9f25-6fc456f45576"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f213ee9e-6ae7-4e82-9f25-6fc456f45576"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "804a9ecc-be85-4926-84d2-1879c6008a6e", "name": "tr(r:p1rdt5483-p1rdt5483lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f903015c-95a7-4d6e-b2a5-e9705c050c6e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a73d544-9f33-49d9-b648-c806addf3c06"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a73d544-9f33-49d9-b648-c806addf3c06"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "e47a7160-32cb-47d7-a35d-f30bb1d87bc9", "name": "tr(r:p1rdt5485-p1rdt5485lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cfb3a23-3a93-4d89-8b70-e4730ebbce1a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40eaefce-482f-4a89-bec1-2c11bac2bfb7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40eaefce-482f-4a89-bec1-2c11bac2bfb7"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "3c03d8f3-d40a-4b30-8f4b-39116f72993e", "name": "tr(r:p1rdt5650-p1rdt5650lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8f1c67e-9e29-45a3-a2a3-c2f3493a6898"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28a6e44b-c6c7-4556-b4d8-d55359391c66"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28a6e44b-c6c7-4556-b4d8-d55359391c66"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "442a6df8-1877-4263-a9de-b6a18ae053ad", "name": "tr(r:p1rdt5653-p1rdt5653lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "769c14db-ac3f-438d-9f7d-c7eb2d3074b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38d1de19-1f51-4875-acc2-a75e3d1a290e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38d1de19-1f51-4875-acc2-a75e3d1a290e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b88a89f2-d5e8-45bd-939b-2476952d2902", "name": "tr(r:p1rdt5656-p1rdt5656lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f417a58d-5a47-4310-bac6-e8bb95fffc19"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "87e8c57e-67ff-439c-b28b-0fbdbfd62ea6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "87e8c57e-67ff-439c-b28b-0fbdbfd62ea6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "a62dc441-3832-46a8-9fe3-5ad01441938c", "name": "tr(r:p1rdt5658-p1rdt5658lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81d6db26-881f-4cae-9514-df4c1e71c76e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f718935b-704d-4374-9172-856511e1eddd"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "1bc7dee2-3a73-4bf6-b9e5-5a51eb44b4ff", "name": "tr(r:p1rdt5662-p1rdt5662lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17e89212-bc51-4fc2-83d1-4c74a285be23"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea73a91a-b052-486e-810b-1a5ad281e07b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea73a91a-b052-486e-810b-1a5ad281e07b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "48c1ed45-922f-4c58-b9d0-26d6c91138f3", "name": "tr(r:p1rdt5663-p1rdt5663lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7356d982-36fd-46cb-9300-8889502e8dc8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16a67a88-5d11-4eca-85fe-38c948ad362c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16a67a88-5d11-4eca-85fe-38c948ad362c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "85ffc857-6af0-4a86-bcdd-734da36e5718", "name": "tr(r:p1rdt5728-p1rdt5728lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b55c58cf-153e-4aa3-b099-8a1db05a6ae5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6d456893-4d89-455a-b1a5-4863aad6293a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6d456893-4d89-455a-b1a5-4863aad6293a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4f92fde2-27d2-48b7-aab1-425ccf2fedee", "name": "tr(r:p1rdt5729-p1rdt5729lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "77d2122b-cbb7-4844-bbb2-55e939431e50"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95f81d7a-a6af-4843-bfa1-002abc7ff870"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95f81d7a-a6af-4843-bfa1-002abc7ff870"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "0783f792-d931-4d06-a008-d6dff90de5cb", "name": "tr(r:p1rdt5730-p1rdt5730lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5897bb2-1f72-4aeb-9090-74e2411b5786"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2dd206bc-965d-46c9-8fdb-8c158c7bba05"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2dd206bc-965d-46c9-8fdb-8c158c7bba05"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "5a2f8d06-f5c2-4ff9-befb-b1580884d748", "name": "tr(r:p1rdt5731-p1rdt5731lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95cd61cf-f1cb-4af2-9d3b-e42978642003"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e414162-eda7-4cf2-9116-fc24af9461bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e414162-eda7-4cf2-9116-fc24af9461bf"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6d3ddf78-01dd-4545-865b-513b8a016d38", "name": "tr(r:p1rdt5840-p1rdt5840lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35722d90-049e-4c67-9654-acce0572e6c2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9974869d-7d87-4a27-9606-076cd7799953"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9974869d-7d87-4a27-9606-076cd7799953"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "7a69c32d-25c9-4ba6-9763-bc883b42aec6", "name": "tr(r:p1rdt5923-p1rdt5923lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fec8a81-a151-4d8f-adc7-6d6d87d7759f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "751d2f2e-bb6f-4ca6-9e86-0e2b5ff3f92a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "751d2f2e-bb6f-4ca6-9e86-0e2b5ff3f92a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "7c2647c5-6bca-4086-b50e-8dc4d3699dd7", "name": "tr(r:p1rdt6038-p1rdt6038lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8898950-d712-40dc-99b5-33882b96b225"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d654945d-b71d-4943-86a2-5830fca200c9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d654945d-b71d-4943-86a2-5830fca200c9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4f7e809a-a82d-4bf0-ac51-229280ce4fd9", "name": "tr(r:p1rdt6043-p1rdt6043lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "87e05b2f-c346-452c-9c72-a6db090c3124"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ae7bbf-f53e-4ae2-8145-bf56ce935094"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ae7bbf-f53e-4ae2-8145-bf56ce935094"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fac52057-f5c2-4934-9fe6-6517159b5db2"}}}}, {"uuid": "df4304d6-f35e-4caa-b702-71b3da08c77f", "name": "tr(r:p1rdt6045-p1rdt6045lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0396342e-2dc8-4a01-9da9-513953f9b5fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70bad714-71c1-4341-ac40-76312417dd03"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "1fda4c61-98bf-494b-a4be-a77eef41867b", "name": "tr(r:p1rdt6046-p1rdt6046lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67bc3ce6-e23d-4899-b0e8-9783225338ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2e2d1a7-039c-4b29-a061-b814ac675e3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2e2d1a7-039c-4b29-a061-b814ac675e3b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "123088f7-943a-4feb-845b-85900240a87f", "name": "tr(r:p1rdt6047-p1rdt6047lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34a9d21e-bcf7-4266-9834-60a72878ddd4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21e75ccd-7e21-4f0d-890c-81aa6b33b109"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21e75ccd-7e21-4f0d-890c-81aa6b33b109"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "62ef838d-937e-4760-aabd-f8478054f480", "name": "tr(r:p1rdt6052-p1rdt6052lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c10f182d-aa76-4633-9a84-f41e20b97da1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d830a1b-6971-4f4d-99bd-945e0785b5aa"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "e1db1007-4c7e-413b-9d88-ee84e9bd8284", "name": "tr(r:p1rdt6208-p1rdt6208lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdfc617f-fbfb-4e9a-862e-cd5a296748cb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01be483b-09f4-450e-a39d-78692c40ee8b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01be483b-09f4-450e-a39d-78692c40ee8b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b0843684-b05b-4654-bc0e-d00707551a2b", "name": "tr(r:p1rdt6221-p1rdt6221lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0809ec5e-d36f-4bea-91b3-962ad6c29606"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73f78740-2ec5-4ad8-b7fb-40f4a72b730e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73f78740-2ec5-4ad8-b7fb-40f4a72b730e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "cf49bac9-27de-4e9d-98a7-f4a7be482fcf", "name": "tr(r:p1rdt6226-p1rdt6226lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d81fc6d7-3400-41d4-91d7-b350d7def98d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3154eee7-a1ba-4b9d-9e91-bab55529d358"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3154eee7-a1ba-4b9d-9e91-bab55529d358"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f910561f-ff5c-4353-ad1e-f22354339f22", "name": "tr(r:p1rdt6268-p1rdt6268lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2f8b91d-339f-4151-90df-b0cad5c2f05a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72ce0706-6b32-4b4b-9bf3-fd1f5a6af5ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72ce0706-6b32-4b4b-9bf3-fd1f5a6af5ca"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "d630f404-730d-43bf-adf8-c8d3a01cf56a", "name": "tr(r:p1rdt6269-p1rdt6269lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5ef97a6-6c60-46eb-acce-6469b273658a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79c91fa8-15ad-4e8d-96bd-2cad395dd280"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79c91fa8-15ad-4e8d-96bd-2cad395dd280"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "194e335f-7fd7-49b3-8533-23c4e6813e0e", "name": "tr(r:p1rdt6270-p1rdt6270lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cf36152-b3af-49f7-b693-5d465db1f283"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5adb2083-3d46-48a7-8996-37c0781b0215"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5adb2083-3d46-48a7-8996-37c0781b0215"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "cbbbeabe-626d-49b9-8577-1ddaec69fd68", "name": "tr(r:p1rdt6271-p1rdt6271lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a75c5e2-2277-42b4-87d4-6eadff5c06f1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1335e64c-9f37-4e73-a37f-8f76737cabff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1335e64c-9f37-4e73-a37f-8f76737cabff"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "74954554-5d2e-4b28-bb8d-40c669296046", "name": "tr(r:p1rdt6272-p1rdt6272lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "034bda10-d48e-449c-9255-247cbf718683"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04422e0a-1952-422d-a201-5fafef1875db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04422e0a-1952-422d-a201-5fafef1875db"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "cd6959a3-3d4c-4eae-aeee-0c9406c769c6", "name": "tr(r:p1rdt6273-p1rdt6273lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d04f281-f394-432b-8b5c-cc1acb741369"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07992f45-0c92-4a10-837d-4f58599d9b75"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "55aac547-fb88-4aa6-8809-ecd9a876ffa4", "name": "tr(r:p1rdt6274-p1rdt6274lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a53624b-8538-4cce-b588-c774875af31b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1db8c80-e791-4c31-a6f2-713aa665bf41"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1db8c80-e791-4c31-a6f2-713aa665bf41"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "0ba41d6b-5061-4da6-a3ac-bb25ac6bf459", "name": "tr(r:p1rdt6275-p1rdt6275lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08d4c459-5bc5-4cad-8e74-613c4a08cb35"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba567584-fbee-44eb-b3f1-da24a0ce66a0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba567584-fbee-44eb-b3f1-da24a0ce66a0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "0dd85bf1-32ee-4efa-9b79-2c455df5d785", "name": "tr(r:p1rdt6276-p1rdt6276lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "315af04d-a032-43a8-a2da-b9e68fd21f39"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f20ace2-5ec8-4451-b7e7-66f46c2c487b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f20ace2-5ec8-4451-b7e7-66f46c2c487b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ecf6f04d-159d-4f51-bf3e-799ca3b33afb", "name": "tr(r:p1rdt6277-p1rdt6277lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1dd4f893-7921-41c3-9e9e-d33e3680a999"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e582b04d-a8d8-4ee9-8576-1e5941623c0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e582b04d-a8d8-4ee9-8576-1e5941623c0b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "8e37ba75-2f21-4e53-a316-b5fab0dd5024", "name": "tr(r:p1rdt6278-p1rdt6278lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51eefb94-724e-4dfe-9823-0f6cf8f56101"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b37eabc-787a-491f-bc4f-956f43a862ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b37eabc-787a-491f-bc4f-956f43a862ff"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4a4f2957-d5d5-4b14-b64a-3c47edce713f", "name": "tr(r:p1rdt6279-p1rdt6279lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "632d8db5-5220-4188-94f0-f6131253820b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6614f5e-517f-46cf-b049-09337d57228a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "6f6b8188-d30e-42a1-93eb-2a1b1bc0bdad", "name": "tr(r:p1rdt6345-p1rdt6345lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40280da5-767c-4610-b6a8-ff411e1c33e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a38eb6d-a625-42a1-95f6-bbf078d1447a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a38eb6d-a625-42a1-95f6-bbf078d1447a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "70aa8f42-99ed-452a-b36c-f06fa56744da", "name": "tr(r:p1rdt6347-p1rdt6347lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7166849-6ecd-4270-bf52-d0579838336a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e40008af-ff50-42bd-8897-f663c27a436f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e40008af-ff50-42bd-8897-f663c27a436f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a13e6c46-4605-4824-91c2-352fb915a87b", "name": "tr(r:p1rdt6348-p1rdt6348lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d6c5b78-35c4-475a-8837-776dea236c95"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d84ac329-f314-41be-a2ee-89bc74789a18"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d84ac329-f314-41be-a2ee-89bc74789a18"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "4ff0e214-7067-4064-9386-9806caf80eaf", "name": "tr(r:p1rdt6349-p1rdt6349lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c1edcfa-e0e4-4493-a9bb-e6033185ce67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdfa0310-7dc5-4181-a64e-cc2522370547"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdfa0310-7dc5-4181-a64e-cc2522370547"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "11b74794-1c6f-47e4-a54f-433e3831c90c", "name": "tr(r:p1rdt6350-p1rdt6350lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c935f1c0-e36c-407d-a2e8-4181c4b0733e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0138b892-d18e-497c-9857-c4d5676deac2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0138b892-d18e-497c-9857-c4d5676deac2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4cd1169b-f163-4253-b934-0f8715170853", "name": "tr(r:p1rdt6353-p1rdt6353lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e51e0d9-24b6-40ac-859a-51ea74c93e76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "015322ae-7712-488f-9569-33fc785e4f62"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "015322ae-7712-488f-9569-33fc785e4f62"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c6442bf3-7517-47a1-a505-20f615795f42", "name": "tr(r:p1rdt6354-p1rdt6354lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a05e7c9-4bff-46fd-b356-8120b481b053"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f06a08bd-05ea-4914-b0d0-07cd0e83bfbc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f06a08bd-05ea-4914-b0d0-07cd0e83bfbc"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a2e09203-34e7-4304-9ef8-79ced26ee5cf", "name": "tr(r:p1rdt6355-p1rdt6355lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "88cc1382-6b14-4500-8a21-662fce6a0c0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1d14a79-4d18-43fe-8790-57ea9adf83a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1d14a79-4d18-43fe-8790-57ea9adf83a8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "7a9d98cb-9394-474e-837a-3acb6f94652b", "name": "tr(r:p1rdt6356-p1rdt6356lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1bdfc1ac-98a4-43dd-bb2c-837d0a2c15f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "548724aa-110a-428f-b71a-acdf0051dc39"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "548724aa-110a-428f-b71a-acdf0051dc39"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "058d6f19-56cc-412c-b1e5-cbcabe0dc8ca", "name": "tr(r:p1rdt6409-p1rdt6409lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42929633-40d4-4e13-a0aa-a7682f328226"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e36cfaaa-3996-4cc6-aa4f-170f20c5d1e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e36cfaaa-3996-4cc6-aa4f-170f20c5d1e0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a340529f-91b6-49c6-9dca-e2917c92ce4f", "name": "tr(r:p1rdt6498-p1rdt6498lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5c5466f-b7e4-4844-967b-9e8b11c68b44"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "e9dd0225-3992-43ea-8011-c92f7dd12ae0", "name": "tr(r:p1rdt6499-p1rdt6499lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "89434ebc-1e79-4414-9925-1a14f8e72fd6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb05d831-1556-4f56-8065-d9d16657caa3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb05d831-1556-4f56-8065-d9d16657caa3"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "78d55ca8-45d5-442d-8aff-41943123d90d", "name": "tr(r:p1rdt6500-p1rdt6500lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78b3b940-c277-441f-b2b3-83525ed85fcb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a20a4242-8a76-49f3-9bf5-3d7aaf751cdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a20a4242-8a76-49f3-9bf5-3d7aaf751cdc"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "4f669b5d-d8e9-463a-b26f-2a4ee9987301", "name": "tr(r:p1rdt6501-p1rdt6501lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99fa55d1-867c-4db0-8697-b532da10d6d4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "5b183af9-59bd-450e-bea6-e545db99accd"}}}}, {"uuid": "34a8f0cc-8b8d-4cbe-a72c-4953ada66769", "name": "tr(r:p1rdt6502-p1rdt6502lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e6348d4-7fcb-4546-af84-8ece75b6332f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7682e9f7-1272-4781-b128-34c7329afe49"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7682e9f7-1272-4781-b128-34c7329afe49"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d400dd14-c9f5-47a1-b904-0451078eb91b", "name": "tr(r:p1rdt6505-p1rdt6505lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb1c1e50-902d-443d-8c9a-b728d2f6b6f1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387e7785-8d40-4ddd-8c2b-14a83d4e7401"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387e7785-8d40-4ddd-8c2b-14a83d4e7401"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "aa0dde85-1b90-4171-9964-b45e0fba3d62", "name": "tr(r:p1rdt6507-p1rdt6507lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0db3e719-4dba-4b45-af70-c35546c19eb4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5844baa-5e0f-4edd-9122-fe4255adad0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5844baa-5e0f-4edd-9122-fe4255adad0b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "30e44c45-a02c-4cea-8908-3cc302637263", "name": "tr(r:p1rdt6508-p1rdt6508lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e165d0d-3f13-4d87-9c4b-fdfa8829f1f3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "e492a34f-e6bb-4fe5-81a5-90fd87eabde0", "name": "tr(r:p1rdt6509-p1rdt6509lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67c889f-e940-4242-9c83-4b5ab673d8a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f817a28f-c650-4eb4-84c0-751fe5053c75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f817a28f-c650-4eb4-84c0-751fe5053c75"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "c9ced24a-5b5b-4df7-8d09-09dd0242098b", "name": "tr(r:p1rdt6510-p1rdt6510lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "848c04de-e4d5-4520-9dce-0073776c2ae4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d62fe3b-7644-46d1-8a15-e86d95ae8b2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d62fe3b-7644-46d1-8a15-e86d95ae8b2a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "5b183af9-59bd-450e-bea6-e545db99accd"}}}}, {"uuid": "c4d3abcf-3d44-4600-8d3d-8ecbac558601", "name": "tr(r:p1rdt6512-p1rdt6512lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f7572ed-6443-4e6e-8fb8-0b060b9f17ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "c95fd30e-d8ee-4e73-8137-8809191cc304", "name": "tr(r:p1rdt6514-p1rdt6514lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0737f6ec-0d5d-4cff-b4b7-9910c7076984"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad6bef77-8f39-43b4-b2d7-58aa6e45a60b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad6bef77-8f39-43b4-b2d7-58aa6e45a60b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "f8a778f3-59c0-4bec-8421-fe311691a98e", "name": "tr(r:p1rdt6515-p1rdt6515lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1537ab1-dc7c-4bbd-b347-fc740d54fcf7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b92f8bcd-91ce-42bd-be69-0b43cb9d4122"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b92f8bcd-91ce-42bd-be69-0b43cb9d4122"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "04865f1a-c24c-4c01-9c2c-2f0900f03c59", "name": "tr(r:p1rdt6516-p1rdt6516lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5bd908fd-8bb8-42c1-8d1b-27c4e2574450"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "119a8559-8e6c-4314-9bbd-37ef3adde415"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "119a8559-8e6c-4314-9bbd-37ef3adde415"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "28fdc699-4ca3-4224-ab12-104819ba90f7", "name": "tr(r:p1rdt6517-p1rdt6517lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b56340a0-81f0-4028-9283-532f0d92a412"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5783bae9-2c74-473f-bf18-db40bc975409"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5783bae9-2c74-473f-bf18-db40bc975409"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f389fc04-f3b3-4f77-9b76-fd9e9c700eab", "name": "tr(r:p1rdt6518-p1rdt6518lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d39c608-5688-4e22-8ac4-96b896265274"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b16b03-1922-4aeb-8e70-d0e1387fbcab"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b16b03-1922-4aeb-8e70-d0e1387fbcab"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "ef0eea90-233c-45ea-8067-2c1f4945c601", "name": "tr(r:p1rdt6519-p1rdt6519lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "addd9f38-279f-4d9e-b216-38faef1940c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "606673ea-bcd2-459a-a0af-efb8b31c600c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "606673ea-bcd2-459a-a0af-efb8b31c600c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "59e61f1f-ded0-4c99-a73c-1f0eece1beda", "name": "tr(r:p1rdt6520-p1rdt6520lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24028ccd-3fd3-4461-b83c-54266f91a385"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13c02cd3-cff3-4988-95b9-3993b9541427"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13c02cd3-cff3-4988-95b9-3993b9541427"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "d566312d-edfe-48bf-928b-511d9fa3d857", "name": "tr(r:p1rdt6521-p1rdt6521lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "302d2adf-2199-47b2-9f3c-e428bb409b6f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0e4e42c-8dcd-47be-bfe8-b8b1eb4a5f24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0e4e42c-8dcd-47be-bfe8-b8b1eb4a5f24"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "01a96d6a-0929-49a6-b5bb-16ac567b9a88", "name": "tr(r:p1rdt6523-p1rdt6523lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b540c710-395d-4a35-8dc3-59d37609df09"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66df2481-ae4f-4f39-aef4-7af09ce1a8fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66df2481-ae4f-4f39-aef4-7af09ce1a8fb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "4121aff5-c528-4441-9261-8852d46e58af", "name": "tr(r:p1rdt6524-p1rdt6524lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ef8c502-c06f-43e5-90e6-23bd0ebcf155"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ec2137a-f978-4808-a023-21f13464998b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ec2137a-f978-4808-a023-21f13464998b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "0913bb9f-6019-467a-9487-635b1c029c69", "name": "tr(r:p1rdt6527-p1rdt6527lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "483b2d65-b496-4c6f-b01d-66aa3d9d4334"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8905812-7e3b-4875-87b5-da95999c5bb0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8905812-7e3b-4875-87b5-da95999c5bb0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "516355b6-65e5-4e7f-96cc-f5f66a86fee1", "name": "tr(r:p1rdt6528-p1rdt6528lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ef5115d-ad7b-4671-b984-b9fd5969bf61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d097d9be-dd3a-4616-a873-8ab5013c4e72"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d097d9be-dd3a-4616-a873-8ab5013c4e72"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "314abd89-9ffb-4e76-bde9-35cd4f3410d0", "name": "tr(r:p1rdt6530-p1rdt6530lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40ec7437-80f0-49e8-806a-c696b1402713"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4ee2d3a-e97c-4ec4-9fa0-d7db1b3e9253"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4ee2d3a-e97c-4ec4-9fa0-d7db1b3e9253"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1e893589-336e-4ed7-ae34-9ffb1e76b82b", "name": "tr(r:p1rdt6531-p1rdt6531lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "385eabe4-8c8e-4354-96ec-931e6c25574d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf4a2da0-682a-4119-b398-feaa6f5a8498"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf4a2da0-682a-4119-b398-feaa6f5a8498"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "aaf01e94-e631-4cbd-9b80-5dd82eae3e7f", "name": "tr(r:p1rdt6532-p1rdt6532lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9f12ed7-454c-4cc9-a631-377121a07ba5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0c3e71a-52a1-49b9-a899-c13d639ac0a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0c3e71a-52a1-49b9-a899-c13d639ac0a6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "16c6d40c-8621-46f3-a9d9-eb9f155486b7", "name": "tr(r:p1rdt6535-p1rdt6535lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b13053e-033e-4fe9-8eb3-89389e4bdc2b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10f0e9fa-75b8-4eaa-a2ad-b6a3fb4ae859"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10f0e9fa-75b8-4eaa-a2ad-b6a3fb4ae859"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "1636c5ab-0f83-47b9-b0b9-95c17d558f42", "name": "tr(r:p1rdt6536-p1rdt6536lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f5cda74-5e33-4c52-8b2c-76bcd5e6c5cb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b93e7299-60a4-49d6-9d34-885860588861"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b93e7299-60a4-49d6-9d34-885860588861"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "81e7d228-2f50-4e9c-a1a5-06c06422eaec", "name": "tr(r:p1rdt6537-p1rdt6537lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "902291fa-9561-4f40-a4b7-4fd9fdded417"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3f191ff-f8f2-4f13-af83-e67d1fdd366a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "a14a1967-2de3-44cf-b403-5c2c78717e13", "name": "tr(r:p1rdt6539-p1rdt6539lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9707f264-8f82-4483-8337-6c89d709faf7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b34f50ff-9a1f-439e-81a8-dfcee658926b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b34f50ff-9a1f-439e-81a8-dfcee658926b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "0982378f-fc34-40cc-8889-8feb46b3d3a3", "name": "tr(r:p1rdt6574-p1rdt6574lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25a9ec20-35b9-4262-a02d-cafa63e5ee42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a43920a-a200-40fe-b5b6-3cdba0c7e784"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a43920a-a200-40fe-b5b6-3cdba0c7e784"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "078928ee-8198-4b34-9e44-3d2464af89ec", "name": "tr(r:p1rdt6581-p1rdt6581lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "599c6ed9-5ff7-4c97-a469-adceecaaf902"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "608e485b-13ce-493b-be96-ab83ad733c92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "608e485b-13ce-493b-be96-ab83ad733c92"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "f15ffb13-3e9f-44b6-9603-dab244b5181f", "name": "tr(r:p1rdt6847-p1rdt6847lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e92b102-eaee-41cc-a2fc-c6c4b3bfb58b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7b9897e-b820-424c-adf8-7416de585357"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7b9897e-b820-424c-adf8-7416de585357"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "e3df7eb1-aff6-4359-acc7-d144d166201d", "name": "tr(r:p1rdt6848-p1rdt6848lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96399e51-1243-4e7f-ae3a-5e2c67123aae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94c9fa37-fc5c-4243-b0ca-f70840febaee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94c9fa37-fc5c-4243-b0ca-f70840febaee"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "d992636b-1b45-4cf4-9b69-e4a53bf53fdf", "name": "tr(r:p1rdt6995-p1rdt6995lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3741c9d4-d03a-4b2f-be57-52a8977351ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09a476ff-48a0-4d27-9cf0-c007e2e98acb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09a476ff-48a0-4d27-9cf0-c007e2e98acb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6973bac5-8bc7-4183-ac29-4d1c42f19e00", "name": "tr(r:p1rdt7015-p1rdt7015lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6278a0d-f5d3-4b11-aee9-3bb23f9954a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "536d7c56-85a6-4167-b4f6-2f39936cd662"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "536d7c56-85a6-4167-b4f6-2f39936cd662"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a0c75282-007a-41ab-9904-5fad1ba4ac01", "name": "tr(r:p1rdt7036-p1rdt7036lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52068090-b613-46d7-a31f-ad3ca26382d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a371c8b-1993-432c-b2c6-21b18bec27da"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a371c8b-1993-432c-b2c6-21b18bec27da"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "2d40d74c-19e5-4154-811a-bf6f0c3b4793", "name": "tr(r:p1rdt7038-p1rdt7038lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb3a9847-70d0-4004-95ef-63884c6c1cdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "046f6c53-8d9c-43a1-88ce-169ade9e9557"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "046f6c53-8d9c-43a1-88ce-169ade9e9557"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "57d5d60c-4bbd-4830-b62b-aef430bbbb13", "name": "tr(r:p1rdt7046-p1rdt7046lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9bb8596a-bcb2-4282-bf1b-9939a9af87d9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cd6a9808-9889-4f16-825d-c9763357c293"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cd6a9808-9889-4f16-825d-c9763357c293"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "88d0b3b4-df75-431e-a234-b9c4c40cd0f7", "name": "tr(r:p1rdt7054-p1rdt7054lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3cf406b-69e6-4aee-a6fc-272dad7693a4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf93e681-3ab6-4929-95f1-1da6d5dd28fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf93e681-3ab6-4929-95f1-1da6d5dd28fa"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9d5af3ee-6de8-428a-bce8-ff4ba5108c9f", "name": "tr(r:p1rdt7061-p1rdt7061lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75947ffd-3765-443b-bef8-b6af746ef624"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc33ade7-4471-40b8-8e9b-1846e0ad60e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc33ade7-4471-40b8-8e9b-1846e0ad60e8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "7b8e2373-7990-4ad0-ac7b-fea580be3edb", "name": "tr(r:p1rdt7067-p1rdt7067lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b470fa62-70d4-4cc5-8f7e-b9cda37481e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ff878e1-3143-4f8e-aa92-74d0a9046417"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ff878e1-3143-4f8e-aa92-74d0a9046417"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "c5a5b6ad-87d0-4856-83d7-f4e3fd1bf17a", "name": "tr(r:p1rdt7069-p1rdt7069lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aae22557-7d34-401d-82c9-2d2710ff2915"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a1566f1-7f0d-41d7-adad-425c9a344eb0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a1566f1-7f0d-41d7-adad-425c9a344eb0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "74945b57-66b3-460b-8963-4876d9317ea5", "name": "tr(r:p1rdt7070-p1rdt7070lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac6e8ccf-75ec-42e0-a3cb-9ab86e2731a4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "844bdc22-2e32-43ee-8e0b-26f3f4c107b8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "844bdc22-2e32-43ee-8e0b-26f3f4c107b8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "56ede37f-8654-4ee4-98d5-b4ca3c882a01", "name": "tr(r:p1rdt7075-p1rdt7075lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8cebb186-4d9e-4d2c-b0d9-100056d34942"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e0577c2-8275-4303-ad11-2c4f56df3f5c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e0577c2-8275-4303-ad11-2c4f56df3f5c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "3c44ca10-17d2-4bc0-8731-abfad4747034", "name": "tr(r:p1rdt7080-p1rdt7080lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "662e2a1c-9a54-4ac3-b478-98e3a478349d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d86bd7f-7759-4d74-9c74-d58010498f92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d86bd7f-7759-4d74-9c74-d58010498f92"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "23574f4e-125b-4c27-9e9f-edd96225a600", "name": "tr(r:p1rdt7087-p1rdt7087lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f614382d-3883-4f6b-b1f6-c8e83d84ee22"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d0c96fe-78c2-4303-ac5c-bbe440f19666"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d0c96fe-78c2-4303-ac5c-bbe440f19666"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "fe0147a8-371a-4e44-a456-842e99895e5b", "name": "tr(r:p1rdt7088-p1rdt7088lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac70c13b-5f4f-45f3-880a-b4b476ea552a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f1652e8-6cf7-43d4-8474-e61a74873675"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f1652e8-6cf7-43d4-8474-e61a74873675"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "49996ff9-e4f6-4f1f-abb7-8f8f1d042cb6", "name": "tr(r:p1rdt7089-p1rdt7089lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31cd4834-477f-4060-8efd-0504c8e8eaa9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73cfcce9-a925-4f29-9cde-6dd6f50735e1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73cfcce9-a925-4f29-9cde-6dd6f50735e1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "625b6c93-5baf-422e-bbe0-ac474e8c21b5", "name": "tr(r:p1rdt7090-p1rdt7090lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08d3a02a-555d-4ad1-9b13-d413b7a16eef"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d6a4c80-d261-4350-8224-8fe5191459c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d6a4c80-d261-4350-8224-8fe5191459c7"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c9e88619-7030-488f-8581-b184ead99804", "name": "tr(r:p1rdt7091-p1rdt7091lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6372a592-5e2d-41c8-819b-f56bfbb58e19"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0c42b48-7ca4-465f-b17c-048cb5f6d79b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "900a59fa-b9e1-4d82-96ad-d7a0e70edd73", "name": "tr(r:p1rdt7201-p1rdt7201lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f64ed4a2-6afb-447c-8c6b-15935e050a6d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6718b871-3967-4c29-83e5-441799c7fb92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6718b871-3967-4c29-83e5-441799c7fb92"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "ebdb125c-15f7-4ac7-8898-a0749c1a885a", "name": "tr(r:p1rdt7220-p1rdt7220lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a2f1a631-48f7-4291-9adb-588a66620ebf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d5e45d6-867a-4442-8258-2c04891dbc4b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d5e45d6-867a-4442-8258-2c04891dbc4b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "46e0dc9d-bf0c-4247-8399-4bba2bf59842", "name": "tr(r:p1rdt7224-p1rdt7224lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eeab7dfa-540c-4275-b159-f6ac4d1350f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d6a6156f-e72a-41f0-a307-e6030de24fde"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d6a6156f-e72a-41f0-a307-e6030de24fde"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c6728992-0569-4ad6-a2ee-a89c059a8cb9", "name": "tr(r:p1rdt7248-p1rdt7248lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a006c5f-e960-4ae2-a37f-d23d7b873a22"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2087cee5-9f6e-4400-8ca8-bbb120cd4dae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2087cee5-9f6e-4400-8ca8-bbb120cd4dae"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "c26eb6ec-9734-4824-8244-a225695d909b", "name": "tr(r:p1rdt7253-p1rdt7253lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f31b09da-e4cc-409e-9634-1907480039ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b4f7df4-5453-459d-8599-48fd5f29a9c6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b4f7df4-5453-459d-8599-48fd5f29a9c6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "13b3b35f-051e-4e07-9ad6-700afdf01778", "name": "tr(r:p1rdt7268-p1rdt7268lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a21680f1-33a7-44e1-9293-98c6861ba2a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1130272e-b98e-496f-aeb9-c094cf9cd824"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1130272e-b98e-496f-aeb9-c094cf9cd824"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "2bf5204f-ad9c-4982-ae22-74ef1aeca8c5", "name": "tr(r:p1rdt7298-p1rdt7298lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b658bf21-450c-4e6b-9dec-c5023a05fd19"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d304e5e0-2cc1-4167-9fad-6fc72228d828"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d304e5e0-2cc1-4167-9fad-6fc72228d828"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "8b3fc746-d9f0-45d0-ad16-d61574e7758f", "name": "tr(r:p1rdt7301-p1rdt7301lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84200441-4c26-4966-a4b7-6b91fb43f02e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43df4c14-a198-4d51-87f4-80000198cd47"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43df4c14-a198-4d51-87f4-80000198cd47"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f3cf9fd8-981a-45c4-8d3c-5f8be4e28074", "name": "tr(r:p1rdt7302-p1rdt7302lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a65c4d3-2fc6-48c8-b944-68c4229db3dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e2a141f-436a-45c0-9c15-179301a439c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e2a141f-436a-45c0-9c15-179301a439c8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "64a649e8-0397-468e-8602-656f8d0a2792", "name": "tr(r:p1rdt7306-p1rdt7306lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "607c7275-da9a-4620-b019-59a66e98c2e6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0926064a-1c87-450a-b282-23708de8aec4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0926064a-1c87-450a-b282-23708de8aec4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "0d51ff9e-3968-4c9c-b1a5-f15632d49f89", "name": "tr(r:p1rdt7307-p1rdt7307lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "231b5cf9-ec2c-47d1-aada-5454926561dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ce9dd2c-9e17-46b7-a6f4-e85077664432"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ce9dd2c-9e17-46b7-a6f4-e85077664432"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6a3a1abe-b81d-478b-9726-5826aada08d9", "name": "tr(r:p1rdt7311-p1rdt7311lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3a4dfb4-e1b3-43b9-ae42-b0cec47ff4ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2d6046b-9ece-4295-a180-41bf2ce47ce6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2d6046b-9ece-4295-a180-41bf2ce47ce6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9d5b01f2-1d26-4772-9ec5-58ed8abd8ee8", "name": "tr(r:p1rdt7313-p1rdt7313lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a3a5e1c-77a2-4a9d-89e0-7d1c94176787"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41e61263-feb6-4264-965a-fd1309d997a1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "34cd711d-2476-4079-bee1-db83e6e89155", "name": "tr(r:p1rdt7314-p1rdt7314lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0cf1844f-a32e-40f2-bc96-05fad3bdd88d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97844fdb-b016-4ca3-8777-b0553ead9297"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97844fdb-b016-4ca3-8777-b0553ead9297"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "92d3cf9e-563c-4377-b3aa-ebfc60ed645e", "name": "tr(r:p1rdt7318-p1rdt7318lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e86bc267-1607-4aa3-916f-ed826b0adfdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22b1ecce-d5df-4f42-abb2-9f4c3d3a28c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22b1ecce-d5df-4f42-abb2-9f4c3d3a28c5"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "0b6fafe7-545d-452c-b7f3-62b2c442f7dd", "name": "tr(r:p1rdt7550-p1rdt7550lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dead8520-e2f5-499b-9316-77780f9b1dfe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58be5cbe-5a7c-4fa5-972d-e03100b3bb46"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58be5cbe-5a7c-4fa5-972d-e03100b3bb46"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4fbe1b16-45a1-4f4f-b54c-4bd9dacab9b2", "name": "tr(r:p1rdt7551-p1rdt7551lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f0f3112-1395-48bf-88c1-8dd4b171478d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c4d7ee3-fc5d-4a17-a717-3d6b6d5a67ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c4d7ee3-fc5d-4a17-a717-3d6b6d5a67ae"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f6bb901b-e888-474e-937e-b47c34f55eec", "name": "tr(r:p1rdt7552-p1rdt7552lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db899c48-a801-4f83-b59d-e587ba80019d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f5d6708-cef4-4aac-9fa0-c738953c788f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f5d6708-cef4-4aac-9fa0-c738953c788f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9ef9d653-e17c-46b4-b8eb-308dcc2d2329", "name": "tr(r:p1rdt7553-p1rdt7553lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddf629eb-ea60-4fce-b731-7ebb33665829"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7a672b2-d127-4fb5-8cc4-8115b8ef3f60"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7a672b2-d127-4fb5-8cc4-8115b8ef3f60"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "1ad1e6cb-ac02-4298-94d9-b6e7b217363f", "name": "tr(r:p1rdt7554-p1rdt7554lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f6de990-0988-4126-86ca-d1fd72c555fe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86a6d184-d883-4e27-aee5-b89c82163284"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86a6d184-d883-4e27-aee5-b89c82163284"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "bd4532f5-197c-4d9d-88b6-69e85596cebd", "name": "tr(r:p1rdt7555-p1rdt7555lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0075333-98fe-4ee8-bb64-a18119b817c0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0de9c581-b78b-44d6-8693-59b995e2a3bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0de9c581-b78b-44d6-8693-59b995e2a3bb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6236b757-e2d7-4dc9-9418-64e399e056c9", "name": "tr(r:p1rdt7559-p1rdt7559lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f239ef4e-83f0-4a2c-ada3-8e30cef38472"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b593ec6-e1e3-48c2-b352-f7966f206aa9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b593ec6-e1e3-48c2-b352-f7966f206aa9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1d28deb4-7339-4686-a9aa-b3814787aab1", "name": "tr(r:p1rdt7561-p1rdt7561lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc6bd64f-1ad3-4bd9-b590-7d4b673a94b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05e30abd-3c40-4dbd-9261-ca8a8abd9c56"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05e30abd-3c40-4dbd-9261-ca8a8abd9c56"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "bb32295e-91d3-4b0d-a30b-f527438019eb", "name": "tr(r:p1rdt7564-p1rdt7564lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa33ca9e-e16d-4c49-8a70-c6c30cf7b038"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7588b3b-f54c-483d-b354-b9908483019a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7588b3b-f54c-483d-b354-b9908483019a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "38f3f4b0-05b8-469e-9bf4-9aa64b723b84", "name": "tr(r:p1rdt7570-p1rdt7570lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9b94106-b7c5-4ce9-9c19-053487848c2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2b3b9e1-3d98-44c1-bd38-9325623a1553"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2b3b9e1-3d98-44c1-bd38-9325623a1553"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c839a693-631e-43a1-943f-063d3e8cac8a", "name": "tr(r:p1rdt7572-p1rdt7572lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4307e78-304a-4175-8e81-9cb23d99f394"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69bf048e-54cd-4e41-a23e-485b0cd98fae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69bf048e-54cd-4e41-a23e-485b0cd98fae"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "14f1f8fd-687c-4967-a86b-790552e9bb2b", "name": "tr(r:p1rdt7574-p1rdt7574lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd487832-bc77-406f-a995-4b099fad7c64"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a742708-0f8b-42d0-a977-b5ce5e36a042"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a742708-0f8b-42d0-a977-b5ce5e36a042"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "40be45f1-06bb-4504-b1e8-03427c7e92c8", "name": "tr(r:p1rdt7576-p1rdt7576lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b28595b-dcbe-4d1b-92c4-94acf370bb1f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56b05024-7907-458d-a5c3-0e54ffbabdb5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56b05024-7907-458d-a5c3-0e54ffbabdb5"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a60ca7e5-fadd-4a55-9aaf-a6336c346d87", "name": "tr(r:p1rdt7579-p1rdt7579lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76f6a27f-0e4f-48b8-9dbd-31c6ffc4ec75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d00b7fe-0384-4c12-a0cf-8895458d3b80"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d00b7fe-0384-4c12-a0cf-8895458d3b80"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "dd238be0-3718-42e1-a1c0-47e911dee99f", "name": "tr(r:p1rdt7588-p1rdt7588lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f2dabc2-0b52-490c-b13a-32c268f6bd33"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abc940b0-c9f5-4582-adaf-ad7f4a79a35f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abc940b0-c9f5-4582-adaf-ad7f4a79a35f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "306bd8de-2bed-4392-b5cd-af1639de22f7", "name": "tr(r:p1rdt7589-p1rdt7589lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f9809eb-41e0-40a8-b43a-93556f767f68"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53e9cf92-1c91-428f-bdff-64257257ad5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53e9cf92-1c91-428f-bdff-64257257ad5b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "76c04b04-3f7a-4a92-8244-2b76e218fa05", "name": "tr(r:p1rdt7598-p1rdt7598lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f95e5fa5-a84c-42a4-b519-8d344e816ecd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff1e0d26-d845-43c3-9aaf-01d1c007b9a1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff1e0d26-d845-43c3-9aaf-01d1c007b9a1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b1a1407b-f572-4475-89dd-fdc7487a6303", "name": "tr(r:p1rdt7599-p1rdt7599lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a086b782-3a8d-44e9-9948-cb7f051219e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d838502-3769-4d70-839b-26fd628ce478"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d838502-3769-4d70-839b-26fd628ce478"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "be508024-b14e-4860-a815-fba0b7e63239", "name": "tr(r:p1rdt7605-p1rdt7605lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e36f1f1-6993-46b0-bafa-9530fd1652ef"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3488ff0-696f-4180-bc70-41ff37f9c365"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3488ff0-696f-4180-bc70-41ff37f9c365"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ab99af7f-f37b-440c-88b1-ff14dfa3d7c1", "name": "tr(r:p1rdt7612-p1rdt7612lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3410d88a-3e9c-427e-a79e-5c602455ed1d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fdfea70-187a-4bbc-ba3f-69cb74c4d5c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fdfea70-187a-4bbc-ba3f-69cb74c4d5c5"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "5633eb80-82db-48b3-b73b-40e06940ca5c", "name": "tr(r:p1rdt7615-p1rdt7615lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "105df8ff-ec38-4cd6-b557-c318b4023bd0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "269e9ba5-bc54-4cbd-9140-4b1bea74fc53"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "269e9ba5-bc54-4cbd-9140-4b1bea74fc53"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "20e0b0a7-7df7-4a70-90c4-c2e51e42f8d2", "name": "tr(r:p1rdt7616-p1rdt7616lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7167a2e-9e83-441e-a15b-0256848c3f6d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6af13868-ecb1-4110-be3f-537741287035"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6af13868-ecb1-4110-be3f-537741287035"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "ab1caeed-4f38-4dd1-8946-e1f37a4e07cf", "name": "tr(r:p1rdt7617-p1rdt7617lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01c9d31d-c3bb-4950-9bbd-00377c252ddc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4be4af94-fee7-40d6-9061-9a0fe0e7377e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4be4af94-fee7-40d6-9061-9a0fe0e7377e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "48f92b1a-dfcd-45a9-a9c8-46f9c5a3464f", "name": "tr(r:p1rdt7618-p1rdt7618lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0fef9b3-a4bd-421c-8a54-cbf6f44c460d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49f37435-54fc-42b4-baba-94f0611c8c76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49f37435-54fc-42b4-baba-94f0611c8c76"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9ba2159e-0ded-4752-ab15-e81614b1a3f6", "name": "tr(r:p1rdt7619-p1rdt7619lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "161d6f3b-8bd9-4fa8-9442-c6ff008e8d3d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a205379-48f9-444c-baf8-dc84fc9c6d8a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a205379-48f9-444c-baf8-dc84fc9c6d8a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ceab5e31-ac40-491f-8469-d2987e18c247", "name": "tr(r:p1rdt7620-p1rdt7620lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97be7ac3-a710-4de8-a666-276813582cd6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af91c50-929d-4ac6-9272-7c44d17a0094"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af91c50-929d-4ac6-9272-7c44d17a0094"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "bdcbb6b6-4e44-48e9-8d5b-4602c5816566", "name": "tr(r:p1rdt7621-p1rdt7621lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa48cf27-3b07-4460-ad9c-8d9862238645"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60f0bddf-6e4b-495c-a98d-f3940d69a5e9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60f0bddf-6e4b-495c-a98d-f3940d69a5e9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "654c6e8e-e5cc-4433-b8a9-4f1e0ff9afb9", "name": "tr(r:p1rdt7624-p1rdt7624lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e240270-762d-49f0-a4e4-29fcd6273ce5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e2075fb-9691-447e-9a73-f88649310bc1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e2075fb-9691-447e-9a73-f88649310bc1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "3e444053-e0f6-4c5e-b83a-778c710b6246", "name": "tr(r:p1rdt7625-p1rdt7625lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3e6cbe9-d1d3-4c59-981f-dad980f0999b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6b1e3b6-ce3a-4ad6-a046-6608530b2ec2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6b1e3b6-ce3a-4ad6-a046-6608530b2ec2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b3029529-3d87-4bf6-855d-9e4acc2459cb", "name": "tr(r:p1rdt7626-p1rdt7626lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56d67e3e-46af-4e2c-86a8-191d97b0ce8a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56f8eed1-77ae-4d65-80aa-7ae148350333"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56f8eed1-77ae-4d65-80aa-7ae148350333"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9123f9a8-9439-48d0-8966-b3c4d4d710e1", "name": "tr(r:p1rdt7627-p1rdt7627lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5bddd75e-1974-41ee-ab51-625c7485a573"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90d8891c-6e6d-46b9-8f88-acc9453c6541"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90d8891c-6e6d-46b9-8f88-acc9453c6541"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9afa56ce-eb98-472e-a5c6-91206e1a8521", "name": "tr(r:p1rdt7630-p1rdt7630lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "723e2b5c-414c-4f3d-ba23-d2df4bc63e75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ad2599f-313b-49c6-abaa-19177e1a9edc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ad2599f-313b-49c6-abaa-19177e1a9edc"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b9fc1aba-239f-4d0d-8085-2dd63d6da04b", "name": "tr(r:p1rdt7631-p1rdt7631lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9e53141-a773-4127-9558-3887070a8f36"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4861056b-b634-4900-94bb-d6c995387351"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4861056b-b634-4900-94bb-d6c995387351"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "752c4be4-3b4b-44b4-ae38-4efa162ae539", "name": "tr(r:p1rdt7632-p1rdt7632lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36e7cd28-6795-41d5-847d-92347871384f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7235cf3a-dd26-47f7-884c-6335024a3064"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "e911abc7-52f8-4093-a459-c3ca4018ece3", "name": "tr(r:p1rdt7699-p1rdt7699lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec849ee4-3d69-46a9-9a2a-242a3943e46c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bfa76dc8-4007-4e52-9692-2eec7cb574e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bfa76dc8-4007-4e52-9692-2eec7cb574e0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f4c59d36-a424-406c-abe0-7ec431462ff8", "name": "tr(r:p1rdt7701-p1rdt7701lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "74968ebc-53c5-4fc6-8172-3ffa9dea7683"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0cc95d09-c799-488e-81e8-50326a7da1ea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0cc95d09-c799-488e-81e8-50326a7da1ea"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "76f31e46-6028-4e28-9c78-d861c071c648", "name": "tr(r:p1rdt7704-p1rdt7704lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02ea9067-6a2a-48b6-b5f1-10992b9fbd77"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ef392d6-b408-4a7f-8a67-9fe43e1df582"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ef392d6-b408-4a7f-8a67-9fe43e1df582"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "aded564b-854a-4916-b3de-3ee4098f53f2", "name": "tr(r:p1rdt7712-p1rdt7712lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4462b9c6-748f-48e9-9ff9-7f20a06cf456"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59a62487-c709-428e-9e97-c7c285a1305c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59a62487-c709-428e-9e97-c7c285a1305c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ac1905ca-2d2b-4806-8ad1-5ac7cd2f4526", "name": "tr(r:p1rdt7718-p1rdt7718lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "048e2bab-67f2-4975-81a1-bbc9f2f9cd88"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6d10a4e-e7bc-4448-bca3-a5f2117b6198"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6d10a4e-e7bc-4448-bca3-a5f2117b6198"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a39660fd-d276-4af3-afe6-1cd2ff97fa07", "name": "tr(r:p1rdt7735-p1rdt7735lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62078787-3ae2-47b3-8f67-8e89e110c8be"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96dcd934-01a0-4719-89bc-a18430edf179"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96dcd934-01a0-4719-89bc-a18430edf179"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "ce2cab85-3bda-4e0e-9cbc-d2bea2fe03e1", "name": "tr(r:p1rdt7790-p1rdt7790lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97198258-8ba3-4950-8747-3241c6a4fcee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ed564b5-8d49-4ff7-94c2-b245981472e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ed564b5-8d49-4ff7-94c2-b245981472e8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c43106ec-5430-410d-a310-0f90dbe8b582", "name": "tr(r:p1rdt7954-p1rdt7954lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21e15d54-eab8-4204-9ed6-407fd8684700"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9dd5bb5-1410-4635-8a85-d23d7c3e55ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9dd5bb5-1410-4635-8a85-d23d7c3e55ad"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9cba1db2-bbe9-438b-a0ae-cbe9c6042c84", "name": "tr(r:p1rdt7973-p1rdt7973lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "016e4575-cd41-4993-be9b-5e5236a139ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3a96167-4b09-49c9-baf7-4fb588ecb002"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3a96167-4b09-49c9-baf7-4fb588ecb002"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "73995ff5-d40e-411d-80e1-03503328178f", "name": "tr(r:p1rdt7983-p1rdt7983lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e261b565-1f57-4cdc-bdd6-e045ee55d290"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb63be48-94ec-4c9f-9991-77892e14171b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb63be48-94ec-4c9f-9991-77892e14171b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "ee7e1b81-29bd-4324-bd7f-edb721cfe6d1", "name": "tr(r:p1rdt7986-p1rdt7986lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "93a5388e-ffd7-403e-b6cf-26b7e81feed1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "415fe6e9-953e-40f6-8ae8-43834e4e6ce4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "415fe6e9-953e-40f6-8ae8-43834e4e6ce4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "40ae26e7-8612-4ca1-af9a-6138c75b525a", "name": "tr(r:p1rdt7988-p1rdt7988lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48e4b67a-0a47-48f0-b787-0a639db89caa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94f12107-697c-4278-95e0-32b6eb49fdb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94f12107-697c-4278-95e0-32b6eb49fdb3"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "68d17fd2-4b36-4948-b180-d122e210a188", "name": "tr(r:p1rdt8012-p1rdt8012lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bfb33cd-0cf1-455d-81e7-3d0472fa1b41"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5b22c57-7912-4e9f-9b06-6a8ff706a58d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5b22c57-7912-4e9f-9b06-6a8ff706a58d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "4d09727b-7ad9-4895-b375-82bcd4bbeee8", "name": "tr(r:p1rdt8015-p1rdt8015lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc543f54-740b-4a7f-b1c5-eb3783a8ade0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6c5d7ff-cfcd-4b30-98db-eb44a95d6841"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6c5d7ff-cfcd-4b30-98db-eb44a95d6841"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9312b2f6-1773-4a40-bf4a-1a6db143517c", "name": "tr(r:p1rdt8034-p1rdt8034lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f83d22a-fa1e-4a4e-aab9-a9dea8ee06e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "972fe574-f88e-4a8d-8845-d5baa2f378a7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "972fe574-f88e-4a8d-8845-d5baa2f378a7"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "67d378fb-5a38-42c9-85a2-d6c5d30de182", "name": "tr(r:p1rdt8149-p1rdt8149lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b706c56-20f1-49ed-9cbe-0ec1491b83e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9951633b-4311-4ca2-9316-3801be13fe97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9951633b-4311-4ca2-9316-3801be13fe97"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b0592825-0ebc-47eb-b648-6b5e9eca65f6", "name": "tr(r:p1rdt8150-p1rdt8150lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78081763-07d2-4989-b492-e1c5178c4097"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cd1ae47-6aaa-4b57-ba44-1e74f6ea54b7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cd1ae47-6aaa-4b57-ba44-1e74f6ea54b7"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d471ae12-2ba6-4052-a460-048edfdc8258", "name": "tr(r:p1rdt8151-p1rdt8151lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c794942-d5ce-481f-9c6a-563a2180a4ba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a8deb5-b46b-4d4c-876c-b44b2258a6fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a8deb5-b46b-4d4c-876c-b44b2258a6fa"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "49759203-777f-49ae-b598-ca28caffe71e", "name": "tr(r:p1rdt8153-p1rdt8153lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b44d5021-4fdb-4618-bcb2-237ecf2e10e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a542ca5-b24e-44dc-8b68-c00aa024afad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a542ca5-b24e-44dc-8b68-c00aa024afad"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a7da70e8-efbf-4e0b-a7f7-eeb682445e70", "name": "tr(r:p1rdt8154-p1rdt8154lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42ab6054-1866-49c5-b2ab-3cf27199c1c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32fefbef-e10b-4758-8c2e-ccafad49aa5d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32fefbef-e10b-4758-8c2e-ccafad49aa5d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "cdab182b-63a8-43ed-a657-4a881f34363d", "name": "tr(r:p1rdt8155-p1rdt8155lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1613a53e-5194-4d26-b83b-475d9f02a32c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51812cd8-eec8-4862-8413-d25a7e9862dc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51812cd8-eec8-4862-8413-d25a7e9862dc"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "8e5d5e35-2a37-4ca3-b6d8-ac657a25cc53", "name": "tr(r:p1rdt8157-p1rdt8157lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a30e197-897f-4516-b4e5-f70081e6f8c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa6d4429-8a95-4ebd-9e3a-9867734245bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa6d4429-8a95-4ebd-9e3a-9867734245bd"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9c6e09ab-62cf-4cf2-ad4b-85f28da49b1b", "name": "tr(r:p1rdt8159-p1rdt8159lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42b9c576-ddba-4be1-bc64-a37d8cbdfa84"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1dd4660-3cd0-4709-b1ef-1c598e5e39fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1dd4660-3cd0-4709-b1ef-1c598e5e39fb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "4e23e836-b3c0-414d-8b6b-35675ebd0a0a", "name": "tr(r:p1rdt8160-p1rdt8160lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38b72c12-2e2f-4d83-8f5a-9d8503dc29eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "232fed6b-fe0f-4a44-93e9-e6675b50c39c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "232fed6b-fe0f-4a44-93e9-e6675b50c39c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "36e7363c-1995-4a3a-86c5-a0ace2ea4bd8", "name": "tr(r:p1rdt8161-p1rdt8161lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25946c74-15c2-412c-baed-8de5f7aecf98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac7e489e-7249-4702-9ed6-131cad34500f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac7e489e-7249-4702-9ed6-131cad34500f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "ce00bda5-ef31-4200-abe8-7edb6e2ce469", "name": "tr(r:p1rdt8346-p1rdt8346lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14b429c3-41da-4123-b661-40cbdfaf33e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9560197a-21d1-4601-8bcb-213df4844f4a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9560197a-21d1-4601-8bcb-213df4844f4a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "e76e538a-44eb-4381-8e37-7fb09b2f63a2", "name": "tr(r:p1rdt8405-p1rdt8405lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60829dab-c129-4017-961a-81435d8afa93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "408d5d7b-fc71-46bb-8de0-2d4e628c29b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "408d5d7b-fc71-46bb-8de0-2d4e628c29b6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d7e934e2-03f8-4a6a-ab5d-ad3b3dd48470", "name": "tr(r:p1rdt8408-p1rdt8408lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28af960e-6f27-483a-8029-0c5f1641f51d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3fe0f77-a7c1-48e3-94aa-30b69f20ca65"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3fe0f77-a7c1-48e3-94aa-30b69f20ca65"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "95aaee68-75c3-4a09-afe8-2ae7e6764680", "name": "tr(r:p1rdt8414-p1rdt8414lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b48f78d-1092-4536-bfb3-029da6a70dff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fca92353-c013-4c41-8507-ec8704410834"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fca92353-c013-4c41-8507-ec8704410834"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "2a2e6bf5-cdb1-4881-a7ba-b0751befd246", "name": "tr(r:p1rdt8422-p1rdt8422lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ce65512-7d5f-4514-b55c-1775e80dd94d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfe35c35-8164-4825-81e3-10a2ece2cb27"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfe35c35-8164-4825-81e3-10a2ece2cb27"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "704a77eb-97a5-44a1-ab78-f3e5768a865c", "name": "tr(r:p1rdt8434-p1rdt8434lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f28de397-0db4-486a-8ce6-9f65c68703b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdc5ef2a-c0d0-4702-b6c6-df08af1e8746"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdc5ef2a-c0d0-4702-b6c6-df08af1e8746"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1ccbc567-041b-40ab-b2c1-6da64ae2a300", "name": "tr(r:p1rdt8436-p1rdt8436lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fcc42825-2690-4965-a99b-e78285a9b84e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b24c9345-625f-499d-96cf-30b2de5839b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b24c9345-625f-499d-96cf-30b2de5839b6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "db06099d-51cd-4922-8556-5fc046213ce9", "name": "tr(r:p1rdt8439-p1rdt8439lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07f340ca-58c2-4331-8265-a39a45c87b75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a38f544-e250-4fc9-942c-946c5cde0a33"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a38f544-e250-4fc9-942c-946c5cde0a33"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c1cf0331-e671-4257-a481-22857029dcff", "name": "tr(r:p1rdt8440-p1rdt8440lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bbfe31b1-38ce-4ae4-9143-bf08c81617e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "049362b4-49de-4e80-921e-ff763aaab2d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "049362b4-49de-4e80-921e-ff763aaab2d1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "bb01e69d-d66e-4622-a9d2-49439101442f", "name": "tr(r:p1rdt8441-p1rdt8441lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b423745-cc70-4c3a-adb0-f648170b4ab1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72c8f08a-0ba5-413e-a805-f9436b41ff29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72c8f08a-0ba5-413e-a805-f9436b41ff29"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d9636448-6ac3-4dab-b534-39f3b2189242", "name": "tr(r:p1rdt8442-p1rdt8442lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6700763-e6dc-4626-ac2b-22985f0043be"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b5ae28a-95f8-4023-aa23-36809fe96b10"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b5ae28a-95f8-4023-aa23-36809fe96b10"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "f401dbb6-1c00-4683-a97f-240f0d404ec0", "name": "tr(r:p1rdt8444-p1rdt8444lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "685fbdbf-47af-4cc2-97ce-354dd04ce915"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "978920e8-edf9-4bee-85f9-45f4081ed0ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "978920e8-edf9-4bee-85f9-45f4081ed0ca"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "e78e59b0-1628-44f3-9f40-434870c7485b", "name": "tr(r:p1rdt8445-p1rdt8445lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc0ee90f-1f9e-435e-bac4-86a4688c48fc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e0923da-550b-479f-b3d8-3e0320db6701"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e0923da-550b-479f-b3d8-3e0320db6701"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ba075575-7d34-4581-bd89-580a7809f865", "name": "tr(r:p1rdt8447-p1rdt8447lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13b8cfc1-d8eb-4f47-b024-c1daacf3771d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5dbc3459-6a17-4075-899a-6aab16fb3ab7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5dbc3459-6a17-4075-899a-6aab16fb3ab7"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "68fa5476-e1d3-4fcb-aae1-82554760837b", "name": "tr(r:p1rdt8450-p1rdt8450lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "184f95d4-cde1-4bf1-8a74-ebc7097cb10e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b4216c8-9e99-446c-ad09-5a09f046dd59"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b4216c8-9e99-446c-ad09-5a09f046dd59"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "832c98de-e0df-4a23-a77c-8bae8f9c82a2", "name": "tr(r:p1rdt8456-p1rdt8456lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0089e5ea-d706-4a74-812f-654ae73eabcf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d094b779-ebcc-4837-9ccb-31808e2a544b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d094b779-ebcc-4837-9ccb-31808e2a544b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f1be4587-95df-49ac-b27e-27bf9042374d", "name": "tr(r:p1rdt8458-p1rdt8458lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "433162b1-2a9b-4187-ba28-ec57503d76f6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e597d8da-e876-44a5-a109-1ce84527c557"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e597d8da-e876-44a5-a109-1ce84527c557"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1be9aa15-7b2b-40a1-9e35-67939a2032bf", "name": "tr(r:p1rdt8470-p1rdt8470lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "442de065-9e2a-4ff8-9100-1298d3fe0f6f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "edb15d92-f98a-4fa2-8129-ad8a39e0dc0c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "edb15d92-f98a-4fa2-8129-ad8a39e0dc0c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "978ee383-d478-4f12-a155-7192f5c3a6c6", "name": "tr(r:p1rdt8490-p1rdt8490lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37c41a4b-e439-42a1-b9a7-0582c528f0e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a84e1424-7faf-4077-9461-b39460f10ef0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a84e1424-7faf-4077-9461-b39460f10ef0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "eb250ab0-b078-4fd6-890a-38d97425c873", "name": "tr(r:p1rdt8492-p1rdt8492lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "307d9c6d-d5ee-4490-95d3-5a9b1d171e54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "127e4cc7-6413-4482-9ec3-40f8bde02d0c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "127e4cc7-6413-4482-9ec3-40f8bde02d0c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "325e4fe1-dddd-4f95-bd62-a4992948ea11", "name": "tr(r:p1rdt8802-p1rdt8802lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26ccaeff-3a34-4835-8906-1145148549c6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95a1a7c7-6055-47c9-a742-c1b81f6c7478"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95a1a7c7-6055-47c9-a742-c1b81f6c7478"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "7e8bf118-8d3d-438f-8fad-151a16e1fcba", "name": "tr(r:p1rdt8805-p1rdt8805lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3444af6b-f9d4-4229-b6b2-2114300c3f94"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "715c92fa-2470-4869-8d5f-0b4f3f8360d4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "715c92fa-2470-4869-8d5f-0b4f3f8360d4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "32c72906-a147-498a-a113-be950d59104f", "name": "tr(r:p1rdt8898-p1rdt8898lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d887dbc-43bd-413e-8e72-5c95a2ed0be8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6ff626c-d2fc-4b97-9013-4fd544d946a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6ff626c-d2fc-4b97-9013-4fd544d946a2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "ef3714fd-edab-4865-a2ad-4ee8d9fde607", "name": "tr(r:p1rdt8901-p1rdt8901lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f23ab51c-56f3-4421-b66e-7cdcf109787d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d53c0a2-78cc-4988-85a4-884ef039f5fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d53c0a2-78cc-4988-85a4-884ef039f5fa"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "955c5326-6c66-4d62-bf37-292638de7f37", "name": "tr(r:p1rdt8902-p1rdt8902lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f44ec9b-338a-4ae1-a26b-26422f218c13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d1c8eb9-7f79-49ad-9e93-6c7cdcc95e22"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "1ee50b0d-7af3-4a06-b0ea-4bc31090e03c", "name": "tr(r:p1rdt8904-p1rdt8904lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2edd17c2-6dfb-4f86-8998-b90a99755e96"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e111e213-bcbe-42c4-b6ab-2c734ff5341c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e111e213-bcbe-42c4-b6ab-2c734ff5341c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "90046b1e-ffaf-44e0-87b3-cb95655e8345", "name": "tr(r:p1rdt8905-p1rdt8905lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "924fc042-6ddc-484b-b09f-c65b35817d25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2777cc-f3fd-491f-a10b-4ed381cb948d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2777cc-f3fd-491f-a10b-4ed381cb948d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "eec52181-4f73-420b-8698-07ba3d2a5ba4", "name": "tr(r:p1rdt8911-p1rdt8911lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26613f51-86bf-4ae1-86c0-f23e48cf606e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c306f79a-0240-465e-a486-d0f11614fc57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c306f79a-0240-465e-a486-d0f11614fc57"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "63095410-c01a-4602-bc80-e104ffc07c8f", "name": "tr(r:p1rdt8915-p1rdt8915lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "361385c6-bb6d-4bbc-ab7d-4a5774e03d82"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2fbbca23-6473-4344-ac2e-cc97078b3d8d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2fbbca23-6473-4344-ac2e-cc97078b3d8d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "40e3269c-7a28-4e20-9fa3-df93e3a99468", "name": "tr(r:p1rdt8916-p1rdt8916lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "adcc33f8-72a3-434c-a021-6c5973713a91"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d268e33-708d-4bae-8348-cad27fd0d81a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d268e33-708d-4bae-8348-cad27fd0d81a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "e40cccd7-b398-4341-a909-7d8cef79eb67", "name": "tr(r:p1rdt9075-p1rdt9075lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "907828f5-8e26-41c4-8fbc-a3744608181a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6752e8f4-9e37-476d-aec2-4a2fe7c1e2dc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6752e8f4-9e37-476d-aec2-4a2fe7c1e2dc"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "adc3a07a-82a2-4e00-a6c8-1099bb4e0b40", "name": "tr(r:p1rdt9076-p1rdt9076lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2ce5116-c4f0-4ac7-a34f-3ba44c99d04b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdd64386-e256-47f8-8cef-1c933f993a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdd64386-e256-47f8-8cef-1c933f993a29"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "8f50d2c0-fc10-4b59-b588-c78fee9366a5", "name": "tr(r:p1rdt9077-p1rdt9077lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b7f2f09-976a-45da-8186-229aeedeb689"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b83eaaa-a092-42ca-a746-db4d9658d62b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b83eaaa-a092-42ca-a746-db4d9658d62b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "7ecefea9-516a-4cb1-8c06-cac3a09bcc5e"}}}}, {"uuid": "557e8429-9e93-4160-bcc4-3af879a36ea8", "name": "tr(r:p1rdt9084-p1rdt9084lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4251587d-600f-40a0-9aec-229fb2e3f2df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f0e4f59-8a46-4abf-9f06-e0383a59a45d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f0e4f59-8a46-4abf-9f06-e0383a59a45d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "eec76648-0280-4fe0-af8d-9f996d84c74a", "name": "tr(r:p1rdt9085-p1rdt9085lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7fcdf409-885c-4c95-834e-988842ed3f5c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "565bbfb1-a28f-4db2-be48-cbd58972025a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "565bbfb1-a28f-4db2-be48-cbd58972025a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "b66392de-bea5-4d55-91a6-d82ab4d1b213", "name": "tr(r:p1rdt9089-p1rdt9089lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b4ec275-bea8-45f2-94cb-5e24e82179d8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8108ac8-2807-4a40-85c2-db21efaadadb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8108ac8-2807-4a40-85c2-db21efaadadb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "ed549b0d-f520-47b7-a35d-6cd2a3169d35", "name": "tr(r:p1rdt9090-p1rdt9090lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52c72b52-1c6c-46f6-adbe-1054eb233c20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fc84159-09b1-4ca9-9a7a-a4fecab19f83"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fc84159-09b1-4ca9-9a7a-a4fecab19f83"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "dd3d2dc6-ddf3-4f3b-80f3-cdfaa7eee7d2", "name": "tr(r:p1rdt9091-p1rdt9091lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "563c6bb3-d8ed-4fce-ad66-3892426248df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e93ea18-150d-4d80-bac7-f3e1b87c5b4e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e93ea18-150d-4d80-bac7-f3e1b87c5b4e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "fe126484-9dac-44a4-b9a7-d0b95131a9d9", "name": "tr(r:p1rdt9093-p1rdt9093lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c29179f3-0b4e-449c-8562-a8fcb675be6c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f0726b7-3050-4c78-9c06-b9fd0c863ff3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f0726b7-3050-4c78-9c06-b9fd0c863ff3"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "658d959f-56a4-46f3-9c64-ca76eaf73c1e", "name": "tr(r:p1rdt9264-p1rdt9264lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bdf3994-bb0c-44f4-b1ea-ab29e73bd39c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c01a9b2-b002-4279-905e-950452f64f32"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c01a9b2-b002-4279-905e-950452f64f32"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a17c260a-bae1-4173-8fee-fc9ea0a4b0f0", "name": "tr(r:p1rdt9265-p1rdt9265lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b336e76f-17f3-4f5d-ba84-f24c3a4e3eed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "77d62813-61d3-4afd-9f21-869e2ea23e17"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "77d62813-61d3-4afd-9f21-869e2ea23e17"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "c682f3a2-335b-4876-b3f3-f17e582fb5fb", "name": "tr(r:p1rdt9266-p1rdt9266lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fbb2bd0-d109-4248-85f3-266fe479677f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78278589-be2d-4d99-9c03-92c221348917"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78278589-be2d-4d99-9c03-92c221348917"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4d59ae8b-6777-434b-8467-62a8e2a3f6f4", "name": "tr(r:p1rdt9298-p1rdt9298lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61ba1001-8b9d-481c-b205-45c6e0beadc1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "208f222c-45db-445f-ba0b-a4a195ca68a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "208f222c-45db-445f-ba0b-a4a195ca68a6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "bf58b1a3-eb94-4a84-8bf6-222f3696dfcb", "name": "tr(r:p1rdt9302-p1rdt9302lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4a41fe9-62ce-45ba-abcd-086ba429baa0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180fad26-0e7d-4e2c-ba17-c8e3315ca278"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180fad26-0e7d-4e2c-ba17-c8e3315ca278"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "3276927a-5d0f-4e74-818b-d91b6f65ebdd", "name": "tr(r:p1rdt9310-p1rdt9310lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3035d22c-c39f-4f07-9fe9-29888b16057d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4940a0e-dcc2-45fb-baa9-aadc84f8e882"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4940a0e-dcc2-45fb-baa9-aadc84f8e882"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "daf94052-bd8a-473d-8d00-900a40a66ce6", "name": "tr(r:p1rdt9311-p1rdt9311lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7011f1dc-1e7d-4961-9a23-620b7f5737af"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9e0aa7d-9097-4370-8f5e-52a5885da85c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9e0aa7d-9097-4370-8f5e-52a5885da85c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "31a8d47b-fb37-4710-af26-3c40bd619792", "name": "tr(r:p1rdt9312-p1rdt9312lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8721684-5439-482c-b8e5-be330d3cf745"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a21f5ca-51ef-4f81-8229-163182f011cf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a21f5ca-51ef-4f81-8229-163182f011cf"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b6d6629c-ebae-47e9-826d-42a5addc585d", "name": "tr(r:p1rdt9314-p1rdt9314lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d25f8d60-8aa7-4975-96dc-eba7696fa8ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3df13d91-365e-411b-917d-b28df5989280"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3df13d91-365e-411b-917d-b28df5989280"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "3f1254d8-6ad4-49ed-91f4-40f1125f1d3c", "name": "tr(r:p1rdt9316-p1rdt9316lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "644c5887-31f1-436c-bbf6-dae5a70743a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c97a99f-545b-49cd-b1fe-4fd9e04bf37f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c97a99f-545b-49cd-b1fe-4fd9e04bf37f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "26117ef4-73d0-4826-814c-c5b074c7979d", "name": "tr(r:p1rdt9333-p1rdt9333lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0da91bf8-b687-47df-a7dc-41e6166fd667"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a68a1c01-a04c-4af6-b1c8-02ddd1d67e0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a68a1c01-a04c-4af6-b1c8-02ddd1d67e0b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "a951a707-992b-4291-83f8-194955fad7e9", "name": "tr(r:p1rdt9377-p1rdt9377lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61972a50-ce24-4ec1-8535-402665b55a55"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e98299cb-8bad-49ea-8627-f3cfe01b9e23"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e98299cb-8bad-49ea-8627-f3cfe01b9e23"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9d097eb6-0536-4329-9e47-689931548ec9", "name": "tr(r:p1rdt9381-p1rdt9381lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5791345-57dc-4f54-ab54-ea63e6a54ee0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e37f182-5a60-470d-8f5b-ba145cc27973"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e37f182-5a60-470d-8f5b-ba145cc27973"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "bb2e720c-aead-4e23-990b-b5d38b5fc81c", "name": "tr(r:p1rdt9384-p1rdt9384lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6eb9c7a5-5ab1-4d9b-a59e-538b68ad0bb9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abd09ea6-221c-47d9-beec-1062e0dd4aa7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abd09ea6-221c-47d9-beec-1062e0dd4aa7"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "35b8a83c-ef5a-4306-832c-66fbeafd2d4a", "name": "tr(r:p1rdt9396-p1rdt9396lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a597011-5e60-46fe-90d6-85728ff0ffa3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc7e0a25-d6d6-4b07-b3dc-4fe5646915e2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc7e0a25-d6d6-4b07-b3dc-4fe5646915e2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d3d8a817-bbdd-4e5c-a3e4-0432297353b5", "name": "tr(r:p1rdt9413-p1rdt9413lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f750e531-5ade-40a9-9bb0-042220ce9807"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8180ee90-a46e-4d85-9742-d47b24f5e169"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8180ee90-a46e-4d85-9742-d47b24f5e169"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f57739f9-f91a-47bd-ab2b-41bc22a489c3", "name": "tr(r:p1rdt9463-p1rdt9463lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "271ab023-4425-40d8-8080-2481c71309b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a015abb-ec63-4b31-9314-283b8499646e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a015abb-ec63-4b31-9314-283b8499646e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "85d043cd-32d6-4018-a524-c982b2241a28", "name": "tr(r:p1rdt9468-p1rdt9468lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b5695dd-714e-4de1-a63a-f142ff0460e1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4dbe1628-cd17-4f37-af2b-dd752c290fa4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4dbe1628-cd17-4f37-af2b-dd752c290fa4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "631e9419-1b56-46f4-baa0-837e133891b1", "name": "tr(r:p1rdt9469-p1rdt9469lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3fd32c7-2866-4699-93a8-dd3a9997d349"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09613257-d4cb-4c50-b35a-8aefc637c0c9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09613257-d4cb-4c50-b35a-8aefc637c0c9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "de8ccb6c-d747-4480-b079-fd149cfb48d4", "name": "tr(r:p1rdt9470-p1rdt9470lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acf91e46-ba32-44c3-a829-14c80a693d7d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1ab8727-2758-4513-8a7d-e02381faf1e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1ab8727-2758-4513-8a7d-e02381faf1e4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "abf8851d-3ebe-42f7-aaba-d53fec8ddcfb", "name": "tr(r:p1rdt9473-p1rdt9473lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4d8bafa-711d-4fd7-8374-7eeaeb43edcd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c14c3211-a0d5-464f-820c-cab04764d907"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c14c3211-a0d5-464f-820c-cab04764d907"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4a2ad2ab-089f-4dac-a5a0-897f492a374c", "name": "tr(r:p1rdt9479-p1rdt9479lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b006c3-79f8-4a27-b76a-d1b458ff2a21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6a8f268-6a5a-4b23-bd91-53c6b031442a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6a8f268-6a5a-4b23-bd91-53c6b031442a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1a93d30f-d1a4-4015-8c87-b38dda765cb8", "name": "tr(r:p1rdt16638-p1rdt16638lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c0d417e-c787-4b0a-a39e-b19ef274b36b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac361065-6b3c-4ac6-96d5-9b474eb3b80f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac361065-6b3c-4ac6-96d5-9b474eb3b80f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "25afcea6-d24a-41da-92e4-6285c2cd8d94", "name": "tr(r:p1rdt16725-p1rdt16725lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2d0eb0b-bbb6-4b3e-bdc6-4c8a0e7d466f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bae9a352-584d-4cf0-9ebd-eb280b684e78"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bae9a352-584d-4cf0-9ebd-eb280b684e78"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f5a6c76a-0ecf-4a13-89aa-362ecadefd29", "name": "tr(r:p1rdt28-p1rdt28lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e71eb2d5-cd10-498d-b9eb-ae337b2f8af6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b3c997d-cd47-439c-aeb9-326e12c2b869"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b3c997d-cd47-439c-aeb9-326e12c2b869"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "86f8773c-114a-4b4c-b9e3-f2717953ca11", "name": "tr(r:p1rdt29-p1rdt29lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b238dc5-7d8e-4b2d-8449-4dc212d7d227"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61fc3980-6aa4-415c-91c1-10d32c7c359c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61fc3980-6aa4-415c-91c1-10d32c7c359c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c02272a2-6a29-4dc3-bc03-1478a851798d", "name": "tr(r:p1rdt30-p1rdt30lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fa95a19-0e0a-49b3-bb86-7103fbaa4110"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d2be3b5-dbfc-4099-af9a-96368e60fe23"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d2be3b5-dbfc-4099-af9a-96368e60fe23"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "3426e057-9462-4775-84b0-7991d0317028", "name": "tr(r:p1rdt31-p1rdt31lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7c543753-fa26-41df-b7a6-3664395c0d45"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3510eedd-535c-4e58-b81e-c5ec09030479"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3510eedd-535c-4e58-b81e-c5ec09030479"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "06dad8ed-fa0c-4bfc-835f-beac3577743f", "name": "tr(r:p1rdt32-p1rdt32lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "834e959c-8ee6-4fff-b1fc-54c20fc0f20b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e374d6d6-1e75-4808-b65a-c7033e1bd528"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e374d6d6-1e75-4808-b65a-c7033e1bd528"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4d7dca1d-26ad-41f4-ae1b-09c3150c2ff2", "name": "tr(r:p1rdt33-p1rdt33lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f55e4012-a11d-4883-baac-9c013aff6058"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "065c8583-45e5-466c-b4c0-1c66bf970abe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "065c8583-45e5-466c-b4c0-1c66bf970abe"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "07af1c2e-7068-4f93-89df-8790c6dfe1c5", "name": "tr(r:p1rdt34-p1rdt34lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a9c4411-f402-464c-ad25-d439b87ef768"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "553a6868-acec-4492-a52d-5aa08414c612"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "553a6868-acec-4492-a52d-5aa08414c612"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "045e1e63-2c81-46df-aaf1-4d47299340da", "name": "tr(r:p1rdt35-p1rdt35lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "edc22f66-e919-448e-b990-76033c281d43"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f98cc066-fca3-4489-9770-047caee3e742"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f98cc066-fca3-4489-9770-047caee3e742"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "686d21ca-2738-4df6-85e2-c888af76c985", "name": "tr(r:p1rdt36-p1rdt36lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8dcdfef-b40e-4f1c-9b7c-e84846f68c5a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a4fb658-c3ba-428a-82bf-b38ae68dd908"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a4fb658-c3ba-428a-82bf-b38ae68dd908"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c5b237cb-07a9-4965-9cd9-3e14350dcdea", "name": "tr(r:p1rdt37-p1rdt37lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dcbfdc3-b597-4e9e-a86f-4d0ff396ba70"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90a16370-67f7-4abd-992c-990d1eb8f17e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90a16370-67f7-4abd-992c-990d1eb8f17e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "da3f8abb-ffb8-4aea-ab9c-4af9437c8824", "name": "tr(r:p1rdt38-p1rdt38lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b45513a3-8e88-45e9-99d3-6d244c90c256"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "752aca33-7682-4e8c-a8b1-624467e02958"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "752aca33-7682-4e8c-a8b1-624467e02958"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f893bdea-9004-4473-94ab-1c3988f9d1b5", "name": "tr(r:p1rdt39-p1rdt39lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a01c83d1-4adb-4b2a-8de3-441d7c1dd054"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "623ec6b4-cb70-4437-9d79-5ec577bc3199"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "623ec6b4-cb70-4437-9d79-5ec577bc3199"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a4e4a009-9d22-4aa9-9fcc-1b5aa8981612", "name": "tr(r:p1rdt40-p1rdt40lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "577124ac-ea2b-4a60-be47-14b0f5db305e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d08444c-79a3-4ba0-8c69-1855a600dea0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d08444c-79a3-4ba0-8c69-1855a600dea0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1fc2c7da-303e-48e2-b221-3ef3ba1d67ec", "name": "tr(r:p1rdt41-p1rdt41lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5b5b3ae-f657-4fd4-a311-ab1dbe9d749e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "793d0bf4-4d9f-4df4-bc95-d528dd7d31d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "793d0bf4-4d9f-4df4-bc95-d528dd7d31d5"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "80968e2c-9233-46d1-bc47-325532bf9287", "name": "tr(r:p1rdt42-p1rdt42lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a778171c-22a1-4320-9e3c-43888d734e34"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8fb27dc9-b404-49d1-84dd-0cde418b037d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8fb27dc9-b404-49d1-84dd-0cde418b037d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "68f7ceff-6b60-422e-bd73-d4d1a0f6e584", "name": "tr(r:p1rdt43-p1rdt43lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7728581d-66fc-4e7e-b2b0-85fa02c90523"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "274aa0ec-f229-454c-b52d-23130bacb97e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "274aa0ec-f229-454c-b52d-23130bacb97e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "8a76055a-3d2f-4462-98c5-e1f8ff4d0cb5", "name": "tr(r:p1rdt44-p1rdt44lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d9ee2ff-e2bc-4d76-b173-5ba5cc48c9b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c813f8a2-226b-431d-a41a-195cf5e8b01a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c813f8a2-226b-431d-a41a-195cf5e8b01a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "16131cf6-271d-4626-98a8-fbae6ee38baf", "name": "tr(r:p1rdt45-p1rdt45lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29a79372-9c75-4a9c-81df-a7491b87e58a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e276abc-bb27-47e4-9de8-adaccbf964dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e276abc-bb27-47e4-9de8-adaccbf964dd"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "76a4d98e-68c5-49bf-910b-f3f35032d52f", "name": "tr(r:p1rdt46-p1rdt46lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05082892-d69e-4c8f-ba19-c2a627e1c345"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aacdcb46-43e3-4147-ac25-3a9c1223e13a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aacdcb46-43e3-4147-ac25-3a9c1223e13a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f0cbaba9-64ec-4d25-8744-ef1281846908", "name": "tr(r:p1rdt47-p1rdt47lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ea0531d-530c-4088-86a1-3de96a8938ea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f031530a-b3fc-4f8e-b0ac-139009d1256c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f031530a-b3fc-4f8e-b0ac-139009d1256c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b0be705e-8c18-4891-b919-bb25a7238d83", "name": "tr(r:p1rdt48-p1rdt48lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1667a8c6-aeb4-4f22-97b8-62ffefcc12a4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f1790fe-a399-46e3-b9e3-5979837777ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f1790fe-a399-46e3-b9e3-5979837777ce"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b0e0d3ff-8ba6-472a-a5eb-d28c6ce44f6c", "name": "tr(r:p1rdt49-p1rdt49lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "137c345c-77cc-4324-bc0e-e0ba896a5f43"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e5bcc7e-f35c-4bbf-a7ff-a82817488b11"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e5bcc7e-f35c-4bbf-a7ff-a82817488b11"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "26b88ccb-02b0-4122-b422-897c4c26a389", "name": "tr(r:p1rdt50-p1rdt50lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c5d8237-0351-4eb2-83e6-13975b37bfa7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8208c617-caa9-46a5-b28a-8a5b0d9898a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8208c617-caa9-46a5-b28a-8a5b0d9898a2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "cc35b6a6-16d4-488e-97ec-7b14db0fa4c0", "name": "tr(r:p1rdt51-p1rdt51lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f5cef5c-bcaf-4cd9-afbb-a18bd14dfcd4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09d7f030-a9b4-4705-82af-6cf140ba64d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09d7f030-a9b4-4705-82af-6cf140ba64d1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "0e0c6d92-cc6e-448f-a29c-1e3178238ad3", "name": "tr(r:p1rdt52-p1rdt52lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6fb1323-f697-4423-a70d-838056200402"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c70a7331-8c41-4370-b053-3eae432d52ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c70a7331-8c41-4370-b053-3eae432d52ae"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "5050b907-1a62-46d6-82b0-89342148ec87", "name": "tr(r:p1rdt53-p1rdt53lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7305e2b-0a48-4630-8b8e-c3819f1c9cd1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2536a0eb-a35c-40d4-9773-b78379e7481a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2536a0eb-a35c-40d4-9773-b78379e7481a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "28ce3059-1ead-42c2-bdee-4daff71b5662", "name": "tr(r:p1rdt54-p1rdt54lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a898f4c-f522-4e69-be4a-e935e339e011"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57889d14-4aac-4aee-a9e2-677a047e8054"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57889d14-4aac-4aee-a9e2-677a047e8054"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a7a2f704-cd96-459a-b12e-4435494a6582", "name": "tr(r:p1rdt56-p1rdt56lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1d8f5898-7d36-4e40-9980-76d11ef18adb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85ad3bf0-7e82-4e32-8106-faddcf725bdf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85ad3bf0-7e82-4e32-8106-faddcf725bdf"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "0c05cc28-0486-48b9-95ba-0b91bb9b6203", "name": "tr(r:p1rdt58-p1rdt58lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a4ccf80-2611-4089-9353-439809aa7854"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3367c40-9f47-42d9-b627-bc502b170f2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3367c40-9f47-42d9-b627-bc502b170f2a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ffc7aa30-29d5-4db5-aab5-dd84d3d0772b", "name": "tr(r:p1rdt59-p1rdt59lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ea7e0bb-bdc5-429a-8889-2f12c94db72e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8aca9934-9439-4ce6-9ee3-475980324054"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8aca9934-9439-4ce6-9ee3-475980324054"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1696924f-e157-42db-86ef-900c1b1cf8bb", "name": "tr(r:p1rdt60-p1rdt60lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d99e903-3536-4a73-b0d5-ca11f5af6e32"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2517cea-05d3-4b7f-b9fc-0df0fde81235"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2517cea-05d3-4b7f-b9fc-0df0fde81235"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "89ed6c2c-a1ba-4a20-8835-2c08c61547b5", "name": "tr(r:p1rdt61-p1rdt61lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "744725a8-af2a-47cf-948f-9d453a932e32"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70f11a44-826f-45b8-9dc3-0f51ce6c9733"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70f11a44-826f-45b8-9dc3-0f51ce6c9733"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "08edc741-554e-4ef1-bd93-218dc727e5ef", "name": "tr(r:p1rdt63-p1rdt63lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab2b6727-4d87-4b00-bd49-ba7a6b1b9ce6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fac6d4e1-b14d-4973-9626-6a4bde2d2a42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fac6d4e1-b14d-4973-9626-6a4bde2d2a42"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "5ad5756b-21d2-45ca-a385-c7e2b2f1bb99", "name": "tr(r:p1rdt65-p1rdt65lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9397c58-45a1-4ec3-bd84-b4cd5b52dc80"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ae9cb89-7cb8-48c6-a5bc-4178ee364ae8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ae9cb89-7cb8-48c6-a5bc-4178ee364ae8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "72eed041-134e-4a31-a0d0-02a861b323f4", "name": "tr(r:p1rdt66-p1rdt66lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99615f32-0614-4c23-a1e1-b3e8e5688cce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfb9fa3b-c758-4c2e-bc51-f297b1ed21bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfb9fa3b-c758-4c2e-bc51-f297b1ed21bf"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f8d59a4d-dfb6-49b3-83c6-0454d6bfd414", "name": "tr(r:p1rdt68-p1rdt68lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb9e5f0f-8bcf-4019-a786-3f24334e9ae7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd2d6296-a302-4027-9e5f-c24a56a1a1ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd2d6296-a302-4027-9e5f-c24a56a1a1ac"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "5e8def15-b1ef-4d36-afe9-0db73af1d8f4", "name": "tr(r:p1rdt69-p1rdt69lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9396562e-4f87-4e04-b248-502b851fe19e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7057debb-bd4d-4156-a253-0f3a14cdd784"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7057debb-bd4d-4156-a253-0f3a14cdd784"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "00e0932e-3680-4ecb-a35f-b8f379416748", "name": "tr(r:p1rdt70-p1rdt70lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50f3b5f3-3fb5-4fb9-b2e6-b37200af0901"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02440066-bc62-4629-96c5-4b497827de5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02440066-bc62-4629-96c5-4b497827de5b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "aec13c01-30e8-4332-b54a-8dac2e56eb19", "name": "tr(r:p1rdt71-p1rdt71lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bcea1fd6-3c51-48af-8528-d3d7bc8e4f01"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e71f106d-4b41-405f-bce9-3d06b336a554"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e71f106d-4b41-405f-bce9-3d06b336a554"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1f2db932-2776-43d2-b812-944ba379f05d", "name": "tr(r:p1rdt72-p1rdt72lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2faff95d-f394-427a-9d62-75224f830c9e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b59eeab-d997-4186-ab59-0424644d5aeb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b59eeab-d997-4186-ab59-0424644d5aeb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a54d9c9c-facb-438a-9923-8a3535cb078c", "name": "tr(r:p1rdt73-p1rdt73lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc531967-1a7b-4424-83ee-e1131c6fd94c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f027d15-df82-4989-93e5-a3b40c862b08"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f027d15-df82-4989-93e5-a3b40c862b08"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "e5380797-1d80-4e0a-945e-4762a3c8c342", "name": "tr(r:p1rdt74-p1rdt74lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b884fef-8b8f-4ed5-9033-b8177d1c7d70"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37880102-8a9c-4f7b-930a-b29a94241866"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37880102-8a9c-4f7b-930a-b29a94241866"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ea369155-ad0d-4a7c-a74b-c12c8e2ecdea", "name": "tr(r:p1rdt75-p1rdt75lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "510ea93c-7dd1-4fa3-ba3f-6c362856c7c1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "699bbf24-59ba-4dba-8bd4-1cf04a7e6e47"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "699bbf24-59ba-4dba-8bd4-1cf04a7e6e47"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "147887b1-2e3e-4a7e-b06c-a473fb5f6bab", "name": "tr(r:p1rdt76-p1rdt76lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfbb212a-9882-4468-86ac-578c93fde1d8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ecf2223-f120-45b4-8aab-a36d60161aec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ecf2223-f120-45b4-8aab-a36d60161aec"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "86c622f6-2403-4cab-95f8-aff9389bf18a", "name": "tr(r:p1rdt77-p1rdt77lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31b06630-2aae-4fe7-9e31-f911c91121cd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3fd9bf7-ecdd-4dcb-966a-f426d5f2ee81"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3fd9bf7-ecdd-4dcb-966a-f426d5f2ee81"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4a5f4547-b555-41df-9f08-d6c0903360f2", "name": "tr(r:p1rdt78-p1rdt78lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36bfd1f1-80ca-4b7d-a68b-9aa77ceff96e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f0255b7-5369-40eb-8814-959b0d4245b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f0255b7-5369-40eb-8814-959b0d4245b6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ecc7b1e7-8a00-4c32-93e5-f1f981ed361a", "name": "tr(r:p1rdt79-p1rdt79lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b32c9763-ddff-435b-a28c-8f65111c6cb2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "624d03d5-ac53-4d58-ac86-62834fa13c61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "624d03d5-ac53-4d58-ac86-62834fa13c61"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "da68cb40-2f31-4750-a2b6-b091f4654833", "name": "tr(r:p1rdt80-p1rdt80lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b03f8e29-a5b2-4bed-b68c-219276674b6a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ce05c72-facf-447f-ba14-cc2ef64579a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ce05c72-facf-447f-ba14-cc2ef64579a8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "87aeed9d-f5cd-4e6f-810f-c6099cb337fb", "name": "tr(r:p1rdt81-p1rdt81lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "063e25be-2abb-49ae-b459-ddd08ba93bb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b610625-09e3-4b72-a8fe-b0c36f5e137c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b610625-09e3-4b72-a8fe-b0c36f5e137c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "83fcf4f2-0d36-4f7a-b36f-b4151a82bc3c", "name": "tr(r:p1rdt82-p1rdt82lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7627cbc6-c54a-432b-8cba-59e448f6d45a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9872669f-fd85-458a-8951-ec12965fb42b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9872669f-fd85-458a-8951-ec12965fb42b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a617b3b6-59a8-4e36-a4ea-11874a9cd427", "name": "tr(r:p1rdt83-p1rdt83lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aa0b7c2-9d55-4faf-8778-76a6f23bcf3e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8dac1e07-5eb6-4945-a3d9-95b77310358d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8dac1e07-5eb6-4945-a3d9-95b77310358d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d41dfd2f-d99a-4bd0-910f-036f4aebe455", "name": "tr(r:p1rdt84-p1rdt84lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e9f4b13-5fb5-46b2-9258-83582d47d61a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdb8aaf1-0e21-42e0-a72d-666646561235"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdb8aaf1-0e21-42e0-a72d-666646561235"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "26f6d003-75a7-4f8c-b229-262ff28235a3", "name": "tr(r:p1rdt85-p1rdt85lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fc415bc-f457-4e9f-bbd4-783a71b67ad6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40f4034e-c735-419b-80cd-d729d75f4692"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40f4034e-c735-419b-80cd-d729d75f4692"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "110f66e7-2818-450b-a67e-5acde54125dc", "name": "tr(r:p1rdt89-p1rdt89lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac4ad276-90cb-48c0-bfd0-1f2aa0233ce2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "468963dd-428d-4810-a28c-1904bc06fa64", "name": "tr(r:p1rdt150-p1rdt150lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12451cbc-eb14-4814-b274-12eb2241c78a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d156fdde-5620-4a6f-b8c1-a3ab986fcc88"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d156fdde-5620-4a6f-b8c1-a3ab986fcc88"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "4ffdedbd-6f86-4c39-ba6a-51dbb16741b8", "name": "tr(r:p1rdt177-p1rdt177lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ad84ef4-4dcc-42f7-99ed-b8d21cebc465"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d64d858-a9f7-430f-890e-a456f8913c30"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d64d858-a9f7-430f-890e-a456f8913c30"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6d4ef4b9-6445-45ff-9620-36a122a1de83", "name": "tr(r:p1rdt178-p1rdt178lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6912a245-ac1c-4ddd-b021-3bc35cbbe2c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3314fa8-a838-4028-abb5-043425fd0785"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3314fa8-a838-4028-abb5-043425fd0785"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "38f32bd3-69bf-4ea6-b2fd-ec94b21cce20", "name": "tr(r:p1rdt180-p1rdt180lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5258d4de-be4c-478d-b752-7f4efb0af0a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3e633bc-311e-4698-a413-9c6cf09c42a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3e633bc-311e-4698-a413-9c6cf09c42a8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "16bc9340-852f-45b4-8c50-5aafae060aaf", "name": "tr(r:p1rdt181-p1rdt181lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79d0fee6-369b-4f95-a2d2-cd05232652e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05401825-91f8-41f8-9204-ab5806458594"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05401825-91f8-41f8-9204-ab5806458594"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "fd2bbd2d-e55a-4574-9301-aa415ede0134", "name": "tr(r:p1rdt182-p1rdt182lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08e378d4-4ca6-4c9e-93fa-36ff87a3cf0f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db407ddd-fb81-4767-99e1-9aeab12fc770"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db407ddd-fb81-4767-99e1-9aeab12fc770"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "8cfbd069-d0c7-45ae-a317-62a2b705c48e", "name": "tr(r:p1rdt209-p1rdt209lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcb27aab-e828-41a6-ad98-d197897a1a69"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4724ea16-dc31-48f8-98b8-b9a223e9a4bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4724ea16-dc31-48f8-98b8-b9a223e9a4bb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "12ffe536-6060-4f3e-907b-af4d833feb8b", "name": "tr(r:p1rdt210-p1rdt210lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d782d5e-3960-415c-9e33-6742777a5a0a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05f6a3bf-d465-4f16-8205-616d1f4dd465"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05f6a3bf-d465-4f16-8205-616d1f4dd465"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "938e5105-62c4-4dab-b455-5ac4f54fcb4d", "name": "tr(r:p1rdt211-p1rdt211lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9401940-26a4-40f3-9b9a-5231a5c4e171"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1d5af6ce-9a4c-414a-bbd8-15d82f50cb57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1d5af6ce-9a4c-414a-bbd8-15d82f50cb57"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "91a80b45-db0d-4e91-b5a9-5fb6548e00dc", "name": "tr(r:p1rdt233-p1rdt233lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f5ed5d5-93fc-4f3c-a78b-df7019863b67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "591461d4-20da-4165-a210-4dbaedd81016"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "591461d4-20da-4165-a210-4dbaedd81016"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "228841e9-58e9-49e3-804f-445cc0619ab5", "name": "tr(r:p1rdt234-p1rdt234lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80331f15-8b31-454c-a289-49cb79923252"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e480f304-b192-4107-91e1-131d481657b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e480f304-b192-4107-91e1-131d481657b2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "40659e90-bb60-4c4f-a678-ce45935e490f", "name": "tr(r:p1rdt235-p1rdt235lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14b85850-d83e-4a5e-83c3-ccb485bb85aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d8a6708a-d098-4e02-aac6-4aba7fdc71a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d8a6708a-d098-4e02-aac6-4aba7fdc71a5"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a5c0e877-4159-4080-9098-05bf7f634c74", "name": "tr(r:p1rdt236-p1rdt236lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "190d6c51-94b6-462e-8fee-cce57f1ab66d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7dd709e3-c5ec-4a01-8297-11f4d1261c3a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7dd709e3-c5ec-4a01-8297-11f4d1261c3a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "7769b43e-a233-4400-b584-7a9f35d5a83e", "name": "tr(r:p1rdt237-p1rdt237lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8c8b8f8-7a41-4d16-b509-2d7c7af9509d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b72726f3-250c-4d98-86bc-5120137bd0f1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b72726f3-250c-4d98-86bc-5120137bd0f1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "7d4d8011-cd32-41e0-bdbf-c7f5d31224e2", "name": "tr(r:p1rdt251-p1rdt251lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b801037a-e1bb-4c5c-8d18-ed285c8c1d3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42dff28c-89e7-4b56-bf23-3dcdd3ca216f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42dff28c-89e7-4b56-bf23-3dcdd3ca216f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "0f9e6d0b-d35a-481b-b931-182fab18aed5", "name": "tr(r:p1rdt252-p1rdt252lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69b2ee46-ab5f-48c8-a26b-170ed2b57fcb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5fd6466-e740-4f06-a842-798195d62154"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "72716a86-0835-4f9b-8e47-9a6051a19336", "name": "tr(r:p1rdt253-p1rdt253lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1a85646-be2b-4b15-9c2f-cc603c7e06df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "704fece3-3b83-4c0b-bcd1-d463b3cdaf6b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "704fece3-3b83-4c0b-bcd1-d463b3cdaf6b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d1c72dc1-3fc7-4da6-9a5d-72909f222914", "name": "tr(r:p1rdt254-p1rdt254lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ab802e3-3a0a-413c-8865-e3b3d08e44a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "655d8f44-aa2f-4548-a1ca-83fcce9fa7aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "655d8f44-aa2f-4548-a1ca-83fcce9fa7aa"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "bf18b63e-79ca-428f-a8b3-d5a935d41cbd", "name": "tr(r:p1rdt257-p1rdt257lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fb307f7-3690-4931-999a-4daab4d8c9e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4c28500-44f7-47c6-b8a8-d1e3468494e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4c28500-44f7-47c6-b8a8-d1e3468494e3"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "96da8edc-0a10-48ed-bb7d-3658fda97e9f", "name": "tr(r:p1rdt258-p1rdt258lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e28087b-b80e-4043-b0f0-0bc82c91f5e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad9ffaef-f21b-43da-9f67-3a8271edb6bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad9ffaef-f21b-43da-9f67-3a8271edb6bd"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c3a4c349-43bd-4f33-98fa-ccf7e44ca6f5", "name": "tr(r:p1rdt259-p1rdt259lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33a0a070-9cce-4a82-bd22-24a65f02ef97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6a0feb3-78c1-4d69-8d18-2a8c3abdcf54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6a0feb3-78c1-4d69-8d18-2a8c3abdcf54"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ecbce8a2-3f89-4fa2-a55a-3bd07a3ac13f", "name": "tr(r:p1rdt260-p1rdt260lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba0ef4a3-43ba-469b-8ce8-ca7a5a984071"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d8d796d8-6750-4ca5-ae07-1b07331ce6ee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d8d796d8-6750-4ca5-ae07-1b07331ce6ee"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6d2548c2-862a-4a2f-b2c3-1d8870d42a76", "name": "tr(r:p1rdt261-p1rdt261lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "209cebda-044a-42a3-b2f0-fe5b76b80643"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fe4ec5b6-61fb-4b66-9e43-19d81af88966"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fe4ec5b6-61fb-4b66-9e43-19d81af88966"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4bd983f3-706d-4920-a462-e4bf12558318", "name": "tr(r:p1rdt262-p1rdt262lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf660777-f77e-4d9b-afff-73a84274c270"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30952601-1479-4770-9b77-9fe3465310b7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30952601-1479-4770-9b77-9fe3465310b7"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "034163b4-1e88-4baa-a811-5fbd58057562", "name": "tr(r:p1rdt263-p1rdt263lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e26e5dc-8c98-4fcd-b125-3265eb00f3f2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c7501f4-0394-4766-a3c5-b17fda7f3817"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c7501f4-0394-4766-a3c5-b17fda7f3817"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "559841a4-f8e4-4cdd-b1c6-04b11c6d09dc", "name": "tr(r:p1rdt270-p1rdt270lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7eca59ac-01f1-40d7-a0ec-51f355285e01"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d33a03d6-fddc-4e47-8018-cd7d290b30b0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d33a03d6-fddc-4e47-8018-cd7d290b30b0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c6c81cef-c3ee-431b-a3ab-6ad7205c02a8", "name": "tr(r:p1rdt275-p1rdt275lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d4e6a87-0313-419f-8feb-7ea3a29f59ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6715c6a-6869-412a-8e59-e5c2eb03c56b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6715c6a-6869-412a-8e59-e5c2eb03c56b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6bb22125-784e-40ef-bbc5-22745e6216db", "name": "tr(r:p1rdt276-p1rdt276lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "186ffdfe-2346-4218-bd6b-b813ea6b3b62"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b478b4f8-8d5e-47b0-a56a-8b991dc8d944"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b478b4f8-8d5e-47b0-a56a-8b991dc8d944"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ae187547-57ce-46fc-9314-8dda6c95cd4f", "name": "tr(r:p1rdt277-p1rdt277lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "add5e39f-f02e-4a61-a156-d5721cec25d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24486e15-ff1e-45b3-aa02-703263f04844"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24486e15-ff1e-45b3-aa02-703263f04844"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4676c5fd-19ba-4329-a862-9e9801bd00a8", "name": "tr(r:p1rdt278-p1rdt278lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b89bfea1-97cd-41f7-af59-9602a3fc6c06"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8af5824-d5d7-4cba-98b7-d72993909f22"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8af5824-d5d7-4cba-98b7-d72993909f22"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d0bfd334-fcc6-47b4-bfc1-72eb7bb1598c", "name": "tr(r:p1rdt279-p1rdt279lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "153bb615-5ee5-4eec-bcf7-94ea0098aeb6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bf679fe-712f-4db6-9df9-debb29b7ee73"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bf679fe-712f-4db6-9df9-debb29b7ee73"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "da111543-380a-4eb1-88b8-031590d01eda", "name": "tr(r:p1rdt280-p1rdt280lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9cb7919-b8bd-46c1-a173-90a5d241c46e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e4eafd2-0f68-4e2a-a62c-89cb877004d4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e4eafd2-0f68-4e2a-a62c-89cb877004d4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "655bfadd-98d9-4039-821c-21dbe9549447", "name": "tr(r:p1rdt281-p1rdt281lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac745c6f-6e78-4a68-affa-649f91d3aa7c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e01a56d-1bfc-4169-9c3e-1373f9dbeb38"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e01a56d-1bfc-4169-9c3e-1373f9dbeb38"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "015e49ce-e6a5-4944-aaf3-b61823a75f58", "name": "tr(r:p1rdt297-p1rdt297lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d32493ec-06be-48ef-959e-779c79c507a3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a8430e1-656f-4fe2-a11b-00adf429d75d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a8430e1-656f-4fe2-a11b-00adf429d75d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d68d8140-dff3-41be-a497-53455f71c1f6", "name": "tr(r:p1rdt298-p1rdt298lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a468f13-c61f-4c01-aa27-c75fb02030e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33e93250-9c11-4650-9469-412129855857"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33e93250-9c11-4650-9469-412129855857"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b887118e-e038-4a64-9fa7-6038d52ec663", "name": "tr(r:p1rdt303-p1rdt303lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9672c49b-8316-4907-b204-7505483210b0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6353ab92-f66f-47d8-97ac-058cf030ff82"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6353ab92-f66f-47d8-97ac-058cf030ff82"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "5d8d8e70-8ce0-42db-a87f-175f615651be", "name": "tr(r:p1rdt304-p1rdt304lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c51ccb17-eed6-4ce0-b839-e7b26001fe3e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a22ac71-bf3a-4016-86ce-fb25f471be5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a22ac71-bf3a-4016-86ce-fb25f471be5b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "0f017bf0-d183-4c7b-80ed-7c974ee6f0bd", "name": "tr(r:p1rdt305-p1rdt305lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b936973-54dc-41e7-a413-8932c31f0793"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90948977-fe1a-43b3-a8a4-86c080ae4906"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90948977-fe1a-43b3-a8a4-86c080ae4906"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "d74936db-efae-41d6-84f2-34c53eef6e48", "name": "tr(r:p1rdt306-p1rdt306lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57a78c71-e5a8-4dfd-8359-e368b7b198fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53eba878-66fa-4d30-8af4-1f583abe5f16"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53eba878-66fa-4d30-8af4-1f583abe5f16"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b13ff87f-aca0-42a0-a97e-45cfc6179f01", "name": "tr(r:p1rdt335-p1rdt335lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b07c4a6-39a7-4521-bce7-3f1ca0ff4a66"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8e448ea-e66d-4e16-80c0-8e742d7cac55"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8e448ea-e66d-4e16-80c0-8e742d7cac55"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1b3a45a4-d129-4c3f-8eb1-9066ad24ac9c", "name": "tr(r:p1rdt374-p1rdt374lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d425a00d-c0e9-465d-9d9b-af4d64708fba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35993388-185f-4d1d-9dcb-16eb7556728f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35993388-185f-4d1d-9dcb-16eb7556728f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "0c577442-ca1d-4668-b313-e9fbb1e29ad8", "name": "tr(r:p1rdt376-p1rdt376lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f2a0358-b10d-4b62-8f8d-9a5054fae87d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d354e81e-b007-4bbe-b1db-50d7afacd0e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d354e81e-b007-4bbe-b1db-50d7afacd0e0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "de6b39ba-8c53-4f20-8506-bd2983c7866c", "name": "tr(r:p1rdt383-p1rdt383lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d49257c8-f8eb-4024-9c02-461d18cdd3d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8569c197-174f-46ef-96c2-e0c674d7b046"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8569c197-174f-46ef-96c2-e0c674d7b046"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b775f5a3-abc7-439d-8cc2-1dfdb80e9ee2", "name": "tr(r:p1rdt384-p1rdt384lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7adf2f4b-f0fd-4c53-abcf-d90fe1a2b4c4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c56b4839-f007-4c9b-93a7-9147399f983f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c56b4839-f007-4c9b-93a7-9147399f983f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "dfb875e0-909c-48e0-a0f3-c240ef90cdec", "name": "tr(r:p1rdt385-p1rdt385lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91f76b91-e00a-4a88-8ee8-ec403c2c7d96"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "579c3e97-d1dc-4306-91e6-4cbbed29f882"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "579c3e97-d1dc-4306-91e6-4cbbed29f882"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "fb2a2471-54f3-48e3-9ee1-13f4e72e499a", "name": "tr(r:p1rdt414-p1rdt414lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3034e62-dd19-4ecb-bb39-6d0566e3a2ef"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29a78735-964b-4381-bea0-01e5b1b79be9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29a78735-964b-4381-bea0-01e5b1b79be9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "860da100-ad3e-4792-8a28-931f8187fdf3", "name": "tr(r:p1rdt415-p1rdt415lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "101c6236-a474-45c8-b065-f5fa045b1107"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "789d55de-619d-43cd-b056-ebe1be4c2dea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "789d55de-619d-43cd-b056-ebe1be4c2dea"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "feeba731-1ea5-4dc1-9a62-c0e1d7795eea", "name": "tr(r:p1rdt416-p1rdt416lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d16d5f5e-a376-4e39-a845-d2cde8800da3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473f5822-3412-4f3d-836e-f62314efa5b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473f5822-3412-4f3d-836e-f62314efa5b2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "47414dae-3422-48b1-bdca-7b83009a888f", "name": "tr(r:p1rdt417-p1rdt417lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "71fa675e-bc20-46f7-b6f1-c88962f9f3cb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98bb09be-6506-49e8-8fd8-1a01d6861162"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98bb09be-6506-49e8-8fd8-1a01d6861162"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b0547079-9b1b-44dc-ab7c-c29dfea00990", "name": "tr(r:p1rdt418-p1rdt418lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16b7f1e9-3405-4c5f-96c7-d5c08d791907"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e189aaf-7650-49b4-83dd-94a29111aca2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e189aaf-7650-49b4-83dd-94a29111aca2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "469de0ef-7a25-4acd-9205-a71329a39894", "name": "tr(r:p1rdt419-p1rdt419lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81cfd2a2-295c-4b73-abba-05ffee810523"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d9603d6-5e5e-4cc0-aa86-1bdb80f7e1cf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d9603d6-5e5e-4cc0-aa86-1bdb80f7e1cf"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "47093818-356c-43f7-a773-06ced59d5483", "name": "tr(r:p1rdt420-p1rdt420lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4cf05060-0a39-49a9-a761-79fb136e2965"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51673983-9230-421b-8501-bf71601b1b13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51673983-9230-421b-8501-bf71601b1b13"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d972da8f-8281-4cb3-ba18-4eb86c2e9897", "name": "tr(r:p1rdt438-p1rdt438lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10620dcc-049c-4417-b4ac-922a56c0d4a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41f19802-32ca-4afc-8418-fe93e3ced1bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41f19802-32ca-4afc-8418-fe93e3ced1bb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1e703d7c-207c-41bd-8432-62623e3294cd", "name": "tr(r:p1rdt445-p1rdt445lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11571d26-573f-49f7-99fd-828dde97afd8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc7e7e51-f849-4bf4-b720-462daeb21932"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc7e7e51-f849-4bf4-b720-462daeb21932"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4ef117e0-3533-4ed5-a707-27b8b79018e0", "name": "tr(r:p1rdt446-p1rdt446lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3dfe357-889d-42e0-a59a-821c9f843456"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0727e1f5-f2ca-4e19-9dc3-89e185002e52"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0727e1f5-f2ca-4e19-9dc3-89e185002e52"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "31791e27-69b5-46d6-8de1-580b87fb30a0", "name": "tr(r:p1rdt452-p1rdt452lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d51e6f65-c45c-4f10-a17f-6ef684a0a06c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44f86829-17fc-4e83-b2a5-705454293161"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44f86829-17fc-4e83-b2a5-705454293161"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "dea578b9-0003-4140-837c-70a58205dfbf", "name": "tr(r:p1rdt453-p1rdt453lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1bb6f93-7aed-47d7-99db-7c17352a42b8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d58e1471-844f-46ef-9d9a-43753b1dee25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d58e1471-844f-46ef-9d9a-43753b1dee25"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "de71a091-0216-4333-98f4-8e2ee12f7aa3", "name": "tr(r:p1rdt454-p1rdt454lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "82459f47-0c6f-4173-8c35-5a9fe5db9713"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b3e7941-9bdd-48f9-a4a5-a553da9bbb57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b3e7941-9bdd-48f9-a4a5-a553da9bbb57"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "7146b2ad-9e2f-4f11-a4a5-d9ea6e8d1f02", "name": "tr(r:p1rdt455-p1rdt455lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "183de04a-a665-4112-a912-1df68b61d164"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53b40b3c-db5a-4fa0-bedb-f293c6eac473"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53b40b3c-db5a-4fa0-bedb-f293c6eac473"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c7fedd72-fdc1-4ce2-9c76-ae0aa80d0095", "name": "tr(r:p1rdt456-p1rdt456lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf205ba7-ac66-4318-aeca-c75eb96cbd1e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6abe982-a205-4607-bacf-08e9d7cb6f54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6abe982-a205-4607-bacf-08e9d7cb6f54"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "780c1284-1c66-4d72-92d1-cf26850a20c2", "name": "tr(r:p1rdt457-p1rdt457lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12fef7fc-57f0-4494-becd-4724b84dbbcb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "866745cc-62c9-429f-8389-fcc5a1710f17"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "866745cc-62c9-429f-8389-fcc5a1710f17"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "226ddf12-0560-4cd0-a652-b078040e8853", "name": "tr(r:p1rdt458-p1rdt458lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b61caefd-d5aa-4019-9ac0-aaf8cedc71d0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67e071ab-e3dc-4779-9e81-585547cd22ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67e071ab-e3dc-4779-9e81-585547cd22ca"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "50a65c14-ae69-47d6-ae06-21a2674632d0", "name": "tr(r:p1rdt459-p1rdt459lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12d5c579-0570-44db-a751-8eeb92355af9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9eb57d99-ae80-43da-b0cb-b26bdd583e1a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9eb57d99-ae80-43da-b0cb-b26bdd583e1a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "93fa4f7d-bc58-4a12-a440-e0c490ea7b13", "name": "tr(r:p1rdt460-p1rdt460lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59b616e5-76b8-406c-843f-5c71398af81b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028bc055-0ee6-4729-8cd2-15bd7153f975"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028bc055-0ee6-4729-8cd2-15bd7153f975"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "1f7a885d-21ca-439d-8116-826789387357", "name": "tr(r:p1rdt461-p1rdt461lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc35f44e-d8d9-41d0-b014-caa3d8d7a91e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd9a4931-435b-4b48-907c-024c0b8a4816"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd9a4931-435b-4b48-907c-024c0b8a4816"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f12f78be-1ac8-4e86-98fe-de6b0683fa21", "name": "tr(r:p1rdt462-p1rdt462lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fcfdc5bf-1c87-42e2-8b35-1f7125d3b5ed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d96f458-607c-4820-90b1-6fb2625ace7f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d96f458-607c-4820-90b1-6fb2625ace7f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "b7ade355-2af9-4a38-a2d7-80f3335d2f0c", "name": "tr(r:p1rdt463-p1rdt463lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7637cfdb-6a14-4313-95d4-e25beba178f3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f660c35e-85f8-4f0e-b03b-806006c76c67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f660c35e-85f8-4f0e-b03b-806006c76c67"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6148cbd4-2f8c-491c-9c54-ff853b4687d9", "name": "tr(r:p1rdt464-p1rdt464lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a634585d-0c70-428e-a3b2-1ec4717d7878"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "749e07aa-74ce-40f2-a352-9c55f9914377"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "749e07aa-74ce-40f2-a352-9c55f9914377"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "70d8c332-07fd-46c0-a5a7-a6324f5ec5bb", "name": "tr(r:p1rdt465-p1rdt465lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a94f7afe-e8b0-4b24-8196-6b05e98c3830"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "433b0872-49c4-452c-941c-8083a72840ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "433b0872-49c4-452c-941c-8083a72840ce"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "780d3254-dfcd-415b-afdf-f9fdb2cce1dd", "name": "tr(r:p1rdt466-p1rdt466lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b20fa59a-8573-461a-9c4a-0d47e40d2601"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f422478c-0d77-48c8-87fb-e883d945f8a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f422478c-0d77-48c8-87fb-e883d945f8a6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "31fd8d26-743e-4351-a4ae-a932c424b517", "name": "tr(r:p1rdt467-p1rdt467lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ae86125-88c3-44fb-9fe9-1a5d820606f6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23ed76af-dcb2-4333-ae4c-d7439a37cf87"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23ed76af-dcb2-4333-ae4c-d7439a37cf87"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4b987818-3fb4-41f5-b55b-d2cfb74befcd", "name": "tr(r:p1rdt468-p1rdt468lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a180b972-cf0e-4a2e-9bcf-a0ad90bb3d83"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b368fb8f-7f4d-4558-b6b2-2e1db4087727"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b368fb8f-7f4d-4558-b6b2-2e1db4087727"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "18968b56-3a29-41e6-8cbd-8e4fe75001da", "name": "tr(r:p1rdt469-p1rdt469lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48179f57-b0b9-491b-b654-81583768923a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d12ab15f-746d-462b-b395-e2b330ba1226"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d12ab15f-746d-462b-b395-e2b330ba1226"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "bac74da6-006a-4067-88ac-cf7b2ae508c5", "name": "tr(r:p1rdt470-p1rdt470lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86178159-ccd7-45a3-b711-ac237321d52a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15ab2647-a801-4cb5-a1f7-528118ff5dea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15ab2647-a801-4cb5-a1f7-528118ff5dea"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "58fdf097-af18-4b81-9503-d9f13735bc26", "name": "tr(r:p1rdt471-p1rdt471lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eed7e6a8-2b4a-4a54-b69a-e3e1a0614213"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40d98c0b-4c66-4581-9553-f5f57c4b27b9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40d98c0b-4c66-4581-9553-f5f57c4b27b9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "346f5458-a006-49fe-9e5e-9c356990a6a0", "name": "tr(r:p1rdt472-p1rdt472lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fa14b51-a977-4e40-8f9c-28249e576fcf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f026a1d3-23b0-4454-a09b-e1c08cc06392"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f026a1d3-23b0-4454-a09b-e1c08cc06392"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b8909095-2209-43a8-8464-b209838a828c", "name": "tr(r:p1rdt473-p1rdt473lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76880999-6f79-4fc6-9367-1c419eee26d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f435ec5-8c03-45ba-925b-83bad9501047"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f435ec5-8c03-45ba-925b-83bad9501047"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "dc6f4797-c71e-4d15-b933-feb4df8752ec", "name": "tr(r:p1rdt474-p1rdt474lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d709af4b-1115-403b-a68d-76c63c93adf2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "839858f4-3b18-40c3-86f3-e27225e6aba4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "839858f4-3b18-40c3-86f3-e27225e6aba4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "7ecefea9-516a-4cb1-8c06-cac3a09bcc5e"}}}}, {"uuid": "a492d8ab-a787-43c8-8be0-cab66a7fe3ed", "name": "tr(r:p1rdt475-p1rdt475lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c39140c6-8892-480a-81b9-738c67ed1591"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1be3e20a-3890-4e9c-b568-ca99421e751c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1be3e20a-3890-4e9c-b568-ca99421e751c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6c7260e3-92c6-44cf-9183-fc804409b3d6", "name": "tr(r:p1rdt476-p1rdt476lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5421facb-0713-404c-97e9-56669fc762b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ffde8c6-9dba-4f13-bda5-a0edf17c736d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ffde8c6-9dba-4f13-bda5-a0edf17c736d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "d82f544d-1e58-46b4-9ecf-d4338fbccc82", "name": "tr(r:p1rdt477-p1rdt477lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d1eb09d-dff4-4fa3-b96f-ef59b63d6128"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7c94703b-303a-4713-95c0-b2933fe0e70b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7c94703b-303a-4713-95c0-b2933fe0e70b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d4ce0825-6ee4-4ec0-b8e1-1563e762a41a", "name": "tr(r:p1rdt478-p1rdt478lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eba354c-f4bf-4c49-a8ad-998ab9489e5a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c93c776d-68b8-4e4e-8e5e-d5e34003473c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c93c776d-68b8-4e4e-8e5e-d5e34003473c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "50c07068-48a1-4f26-a8f9-e98aa62f0fdd", "name": "tr(r:p1rdt479-p1rdt479lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85acd1fb-6da3-432a-9508-855ca991641b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8037b713-d948-43c9-8370-fb8fcf6dec15"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8037b713-d948-43c9-8370-fb8fcf6dec15"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d06c50e8-54b3-4baf-9665-3fab274a9a46", "name": "tr(r:p1rdt480-p1rdt480lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e5c3d02-1cd2-45e4-90d3-10b135c65f13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "423402f9-4160-481b-9951-a955f8314075"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "423402f9-4160-481b-9951-a955f8314075"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "733cc0fd-6a39-4cd5-981f-4aa1b1b62549", "name": "tr(r:p1rdt481-p1rdt481lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cf3136f-6dbe-4ed7-b9cb-e9f73b191f76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1761b021-00e0-4880-9f05-62cf67aef0e6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1761b021-00e0-4880-9f05-62cf67aef0e6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "148864d6-cab0-456d-8328-a75ad9b03ce3", "name": "tr(r:p1rdt482-p1rdt482lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10c2463d-8563-4737-aa7d-e1195c0af9f6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c445ea76-5167-4d55-b0c5-cc53dadc5b5e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c445ea76-5167-4d55-b0c5-cc53dadc5b5e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "16ca4d3d-9bed-4e6b-9ece-eb18548033ae", "name": "tr(r:p1rdt483-p1rdt483lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69b5d686-dae0-44c5-a261-f1a73bcb168e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "475b6a50-9814-4016-bb88-be5b1b2ac31d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "475b6a50-9814-4016-bb88-be5b1b2ac31d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "ab0dffc8-6dfa-406d-b78d-386b299b2e2a", "name": "tr(r:p1rdt484-p1rdt484lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b57b8e2b-62c2-49a0-801d-02cab8092ebd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f396745a-5edb-4ab8-8bc7-2b181719cbf4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f396745a-5edb-4ab8-8bc7-2b181719cbf4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "2bc14fe0-06d7-4d06-b082-4fa14b69d913", "name": "tr(r:p1rdt485-p1rdt485lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "445f61a4-8045-4558-a3c1-bb44336737ec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da38ec0a-f37d-4a5c-8da0-93410a8fb475"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da38ec0a-f37d-4a5c-8da0-93410a8fb475"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "181d142b-a1d2-40c7-919b-2bfaf1cb98b1", "name": "tr(r:p1rdt486-p1rdt486lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd2f4b00-6e8b-4faa-a760-7c28f8d36a36"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5401d366-a5a2-4753-82b7-ce4fa08a1227"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5401d366-a5a2-4753-82b7-ce4fa08a1227"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "e13b87a6-1453-493b-90f8-63417bffadc3", "name": "tr(r:p1rdt487-p1rdt487lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfb0d992-ab18-4f73-933e-a01ce73ef3b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47fbd02f-6c12-4bd6-9d6d-2e0cddbfcd88"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47fbd02f-6c12-4bd6-9d6d-2e0cddbfcd88"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "bea3ce73-1bb4-443c-82bc-d9633e9913c4", "name": "tr(r:p1rdt488-p1rdt488lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fa474a3-1d6b-454b-9170-6a8d13789c43"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e517b810-e6b9-4c89-b47d-1921fcf88edc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e517b810-e6b9-4c89-b47d-1921fcf88edc"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d221e7c0-5e3a-459f-9f2a-d00e62491d88", "name": "tr(r:p1rdt489-p1rdt489lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cee642e7-12f0-4746-841e-d8cda6fff57e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25637062-8ca3-4694-a27b-7be93e89fe1f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25637062-8ca3-4694-a27b-7be93e89fe1f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "948d2dba-9df5-4bb4-af04-fb9494f3d65b", "name": "tr(r:p1rdt3776-p1rdt3776lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "170a2bcb-d7ce-4617-855b-9111b84262ed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ae14df0-ab3b-47ba-9f83-c09f03999c76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ae14df0-ab3b-47ba-9f83-c09f03999c76"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "bea0945a-b96b-4d1e-af74-0291cbd1a874", "name": "tr(r:p1rdt3777-p1rdt3777lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f9af980-79c4-4daf-b8fc-44e02953f98b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4662f3f5-e75b-4b75-a6d6-7ada745d5cca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4662f3f5-e75b-4b75-a6d6-7ada745d5cca"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1c340bc5-1d86-44e6-860a-aa40bf29d777", "name": "tr(r:p1rdt5098-p1rdt5098lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9100fbd6-863e-48b2-94ed-aca1ef0947bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e734d7a2-9161-41c0-ba78-9f9f87120acd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e734d7a2-9161-41c0-ba78-9f9f87120acd"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "7f4eefd7-8cd4-4fbc-b0c6-c16c3485fc58", "name": "tr(r:p1rdt5548-p1rdt5548lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bf1b63d-fbce-42f8-9948-2e09bfa67409"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91754be7-2a91-4a0e-9856-43d08ecc7c70"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91754be7-2a91-4a0e-9856-43d08ecc7c70"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "9ccccbb6-1805-4071-91ed-04ab43c1c51c", "name": "tr(r:p1rdt5551-p1rdt5551lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f7fed4f-197e-4a79-97e5-df595377736b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9dec144-ef2e-44fe-990a-c9d70b740410"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "c1bbd3f0-4b5f-4f5e-9f82-e2b15dd3929a", "name": "tr(r:p1rdt5557-p1rdt5557lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cca8918c-30e6-4619-a5e0-8c0d3451f9c4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05b867e6-2f18-49e7-9869-55bd5048c201"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05b867e6-2f18-49e7-9869-55bd5048c201"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "28066d5a-8a37-45e6-9713-935dbb6c1a49", "name": "tr(r:p1rdt5560-p1rdt5560lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68117bef-16c5-40c9-9356-76ef5c056650"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5838960-8556-4e4a-95e9-8ba9ffc85141"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5838960-8556-4e4a-95e9-8ba9ffc85141"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "16844ce2-d0e7-4577-8d19-df2522470625", "name": "tr(r:p1rdt5561-p1rdt5561lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "756f6cd8-301b-4fac-b414-d72853616c6e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "133a0221-0cd5-46d2-af84-e80e7951c96d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "133a0221-0cd5-46d2-af84-e80e7951c96d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "eab10644-9384-4c94-aa36-fb0daba50b19", "name": "tr(r:p1rdt5563-p1rdt5563lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad24f98d-f022-4e62-b80b-426052810759"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a150dd3-61a4-4df9-90e2-6c72f80af819"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "9a8345b1-a786-435c-b6a2-aa53580a9679", "name": "tr(r:p1rdt5564-p1rdt5564lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8444c9ea-ff7a-4b0a-9ea6-9c18770565cb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8deb73b9-51fc-447d-9da7-14a6dccff646"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8deb73b9-51fc-447d-9da7-14a6dccff646"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "3e20fcc3-e522-405e-b12e-8621cb7b680c", "name": "tr(r:p1rdt5565-p1rdt5565lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5e479d3-aae0-47b8-b707-bad1191df1e7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60dc1291-a843-4abf-bfc6-ff8afc8c0b98"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "ec61176f-dfbb-4efa-9041-5ed2ff4bf1e3", "name": "tr(r:p1rdt5566-p1rdt5566lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fed9557-b170-4817-8bd8-efc3b9f7c982"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95a5450a-6630-41b8-863f-0c1f3fcfa7ab"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95a5450a-6630-41b8-863f-0c1f3fcfa7ab"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "947b40bb-4805-40ad-a01b-6cf8e7426679", "name": "tr(r:p1rdt5568-p1rdt5568lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c83b6ee-20fc-4ca0-a778-44735283afd5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "613d178b-a566-408d-bad0-e4a170eea971"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "613d178b-a566-408d-bad0-e4a170eea971"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "64da0817-f4a8-4b5f-821e-148131beb92e", "name": "tr(r:p1rdt5574-p1rdt5574lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9906676-e9b9-4d51-b1c2-a6b6fe187faa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "248e065d-80ed-4926-9625-295c83da6b61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "248e065d-80ed-4926-9625-295c83da6b61"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "999c9328-68fe-4d34-86d9-ce9c7fb60c2f", "name": "tr(r:p1rdt5577-p1rdt5577lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1c8b424-4509-4fd2-93e2-4fd54f6cf49a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21ef4ae6-b80e-49f1-8d00-1cb6e27bc8f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21ef4ae6-b80e-49f1-8d00-1cb6e27bc8f9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "e453767e-243b-4848-8e6f-d4589c09194a", "name": "tr(r:p1rdt6261-p1rdt6261lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53e5fee4-5a31-448e-8bd0-d8996468d085"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9859b30-0238-493e-be1a-cb6717413ba9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9859b30-0238-493e-be1a-cb6717413ba9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d1f70d0a-2390-439b-9b24-5f2fd1ba1b0e", "name": "tr(r:p1rdt6262-p1rdt6262lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf092ec9-ecda-4216-9ac0-0bc035973515"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2172b57-622b-44c1-8388-f1e2b1def312"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2172b57-622b-44c1-8388-f1e2b1def312"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4c14ecdf-6121-49db-8273-ea7012401a9f", "name": "tr(r:p1rdt6263-p1rdt6263lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c61df077-693e-4e67-aea6-ee60b99406d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4717b000-fd39-4647-9fbd-5152323dacee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4717b000-fd39-4647-9fbd-5152323dacee"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f6f3fa51-a1a9-40ca-a3b6-7a6ccdb26701", "name": "tr(r:p1rdt6264-p1rdt6264lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a03d20d-664a-4e80-abec-a36910787829"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e916c16-525d-4092-b627-ad44b4bf4ee8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e916c16-525d-4092-b627-ad44b4bf4ee8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "836aa093-a7b6-4940-8c75-2a7058b9fd71", "name": "tr(r:p1rdt6265-p1rdt6265lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d316c13-77c1-4412-baf9-801f7e5ae407"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6bb5544-e583-4ded-9a10-23be70f5598e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6bb5544-e583-4ded-9a10-23be70f5598e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a7f86fff-0adf-4b9e-a9b6-97e3117ec95b", "name": "tr(r:p1rdt6266-p1rdt6266lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e22d08f0-2afc-426a-a0c0-6b00cc1103aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8af5f9d5-965c-4a0c-a811-67d3bed744ee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8af5f9d5-965c-4a0c-a811-67d3bed744ee"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "30021e75-15ad-4990-ba5f-192e884daaac", "name": "tr(r:p1rdt6267-p1rdt6267lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a1d9cfa7-0024-4896-a263-2715086f2ad6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0ddd898-3193-4bff-80f4-fd4a7eae9aec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0ddd898-3193-4bff-80f4-fd4a7eae9aec"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "5db55ec0-9b26-43e1-82d6-1c6f792b80a2", "name": "tr(r:p1rdt6488-p1rdt6488lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63b2f1e6-5e15-4433-85ee-ff7bb7218b96"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1155c2c-544c-45f4-969f-b3ec4f6773bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1155c2c-544c-45f4-969f-b3ec4f6773bb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "cca02abb-5240-4ef2-a315-f28e00a41488", "name": "tr(r:p1rdt6578-p1rdt6578lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e257530-1fe2-410b-83a1-57789e6ddeda"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "555453a3-3fb7-426a-bbd2-9e588d4bd01d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "555453a3-3fb7-426a-bbd2-9e588d4bd01d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "82e64de1-effc-4dc0-8ddc-bb009d05dc60", "name": "tr(r:p1rdt6580-p1rdt6580lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68298e92-fca3-44e9-9271-f79be47c9c63"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5de250a8-ecca-4ab4-9f09-685aaf92d13d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5de250a8-ecca-4ab4-9f09-685aaf92d13d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "405b2028-87da-44cf-b232-708b560b6d4b", "name": "tr(r:p1rdt6584-p1rdt6584lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9f273a36-c30d-4962-81f4-26f8d20e1cf4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d944119-3782-49dd-8b24-1f68d8ee687c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d944119-3782-49dd-8b24-1f68d8ee687c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "c275a539-c206-4c1b-b36e-ae22a3bf13dc", "name": "tr(r:p1rdt6587-p1rdt6587lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d77add8e-ba22-4b44-9c0b-0bddc251a573"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c587698-7940-4edb-9105-f31f1304f7e9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c587698-7940-4edb-9105-f31f1304f7e9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "8aca787a-f329-4a51-90aa-09e490eaa499", "name": "tr(r:p1rdt6588-p1rdt6588lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1648fe3-a7f9-47aa-b168-d2b56cf220e7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61045f72-ca3d-4e0d-ac3d-db5fbf099b38"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61045f72-ca3d-4e0d-ac3d-db5fbf099b38"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "95128a03-d470-48ae-9a19-83abda77d90b", "name": "tr(r:p1rdt6590-p1rdt6590lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5291ea2b-6990-407b-b8d4-d6868bf37310"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a289017a-8ab9-4412-857a-694b3aa2c63d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a289017a-8ab9-4412-857a-694b3aa2c63d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "0672aaa6-8f76-454c-95bd-e281f1293e08", "name": "tr(r:p1rdt6591-p1rdt6591lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1d0a85a-62dc-46d2-bae1-d43d07743a34"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a7c2e99-857f-4119-be4a-daaca586f056"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a7c2e99-857f-4119-be4a-daaca586f056"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "43ad826f-468f-4f62-98d4-419243839bab", "name": "tr(r:p1rdt7286-p1rdt7286lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02351140-e632-49e2-83e4-7e5bc1c8856a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ad975da-cce7-49cb-be78-20c4abf8975e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ad975da-cce7-49cb-be78-20c4abf8975e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b64f19d8-c621-4f06-afaa-159a18f970d5", "name": "tr(r:p1rdt7289-p1rdt7289lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f8375b7-7bdd-409c-9fa1-5c13bd233364"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56d21681-3c57-4575-af17-f2bbf9874a10"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56d21681-3c57-4575-af17-f2bbf9874a10"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f9343681-c623-4b98-830a-4a29714dd9c3", "name": "tr(r:p1rdt7293-p1rdt7293lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4afa9bec-d8da-4449-ab96-9f875bae3c33"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9b0c16f-f433-4aa1-8d00-dc1573dfb5e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9b0c16f-f433-4aa1-8d00-dc1573dfb5e3"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "60823e00-c5b4-4bc4-b042-fad0c40a99f2", "name": "tr(r:p1rdt7294-p1rdt7294lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a955da2d-e212-4026-b1fb-0021a04ded07"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67d2b31-f05a-4160-83ae-55154224a9ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67d2b31-f05a-4160-83ae-55154224a9ca"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "74ab20a7-57a7-4622-ae93-7d3d717abc43", "name": "tr(r:p1rdt7299-p1rdt7299lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d065da7b-7e88-4e63-a47c-959f4d4c6e1c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4cee417a-3410-4907-8621-f0d3fcbc047c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4cee417a-3410-4907-8621-f0d3fcbc047c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "169914f1-885b-4f8c-8e51-c5f5b78521a8", "name": "tr(r:p1rdt7300-p1rdt7300lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05f14a3e-053e-4b65-b962-da7804b9e2c1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "135a6a49-6562-4c6e-a41f-f5f78c0ac3e6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "135a6a49-6562-4c6e-a41f-f5f78c0ac3e6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "de07b9e3-46b7-43d8-be06-8daf46d20cfd", "name": "tr(r:p1rdt7303-p1rdt7303lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6f24e3a-088a-4d1b-8292-03015289d88e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7cbc8145-b198-46f1-a3fd-55a05637e618"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7cbc8145-b198-46f1-a3fd-55a05637e618"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c7531bac-a558-4fc5-abb3-cad5e268ecb0", "name": "tr(r:p1rdt7308-p1rdt7308lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2e605b4-fe7a-4571-947d-8ae19de627d8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5094655-6494-44a9-b0ff-c5b418dcc11e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5094655-6494-44a9-b0ff-c5b418dcc11e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "3d21883c-9d1b-4ac2-882a-5f72cfb7a512", "name": "tr(r:p1rdt7316-p1rdt7316lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6322bf4d-0976-4bae-94c0-f76f83ccb9bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a289e26d-2d86-4fdf-942b-881b91ca18eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a289e26d-2d86-4fdf-942b-881b91ca18eb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c412fc0f-8313-41e6-84c6-5d4022182b14", "name": "tr(r:p1rdt7317-p1rdt7317lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48efebbb-c70a-47d3-aae3-0e39088fc455"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16c465cf-c4ae-4702-ba6c-0b7704eda764"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16c465cf-c4ae-4702-ba6c-0b7704eda764"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "fa23fabe-02fd-4549-80aa-192a59aeac79", "name": "tr(r:p1rdt7321-p1rdt7321lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b468be25-1324-46ab-9424-887741ca1134"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c855f7bb-1f33-4c3e-9deb-e3f9c5aba07d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c855f7bb-1f33-4c3e-9deb-e3f9c5aba07d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "94144af1-4cd0-49b9-aa6a-bb93661492f8", "name": "tr(r:p1rdt7737-p1rdt7737lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d2ea25e-3d48-4b1d-9e52-768752de2e09"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35be767a-53a1-4fe1-b320-9542dd859d97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35be767a-53a1-4fe1-b320-9542dd859d97"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "53d064dd-1417-4642-8abf-df6fd0b5bb7b", "name": "tr(r:p1rdt7753-p1rdt7753lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d142315b-a247-4a4d-a178-73e3c150a188"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7482f0c-eb85-4e30-a09a-eb9f15bbc22b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7482f0c-eb85-4e30-a09a-eb9f15bbc22b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "05232de7-0f14-4d8a-8559-1177a07f9e5e", "name": "tr(r:p1rdt7757-p1rdt7757lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "081feb5c-d5d5-405e-85d4-f1dd0916fc3d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d343e634-0936-4f21-9e2c-079e19f0dfa1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d343e634-0936-4f21-9e2c-079e19f0dfa1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "51d1c01e-6f22-46ea-8d46-dd93a1b50d2e", "name": "tr(r:p1rdt7791-p1rdt7791lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4413ca7f-fdd1-484e-a0ba-3ff2447ebfef"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28e5f84f-2fac-4b5c-a669-b16988e4d6ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28e5f84f-2fac-4b5c-a669-b16988e4d6ae"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "eb25695e-13e8-42e0-a678-e5405a877c1f", "name": "tr(r:p1rdt7795-p1rdt7795lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bee93ff6-6ff8-4572-b339-c8e897dac81b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3959f944-18f5-4daa-a454-3c6bfb7158ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3959f944-18f5-4daa-a454-3c6bfb7158ff"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b2fecd2c-00e0-43d7-9dc2-60a9fddea649", "name": "tr(r:p1rdt8105-p1rdt8105lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3f91816-7c3f-4fc7-98a5-6dee55e52e9f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b2ec0ba-a854-4631-b97a-4674123d6fe6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b2ec0ba-a854-4631-b97a-4674123d6fe6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1b65440f-5d1e-4c19-b277-993ab8fb0f7b", "name": "tr(r:p1rdt8111-p1rdt8111lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2c69fef-4afb-4bb3-9828-096b812de54a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b639e55-2e33-4582-bb96-06a9d33a3419"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b639e55-2e33-4582-bb96-06a9d33a3419"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "8183c724-3202-4128-b82b-1bc73f3b6420", "name": "tr(r:p1rdt8138-p1rdt8138lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17b633c6-214d-4428-bded-df737f50ffb6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dca9b40e-ed8a-4f75-a703-91539f6c3075"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dca9b40e-ed8a-4f75-a703-91539f6c3075"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "be148e43-4847-4b1e-a963-f6389733140c", "name": "tr(r:p1rdt8146-p1rdt8146lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc34073b-94f6-4c75-8144-8f624bac9cc7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2bee3961-990e-47ac-b49b-d305f8fe0af8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2bee3961-990e-47ac-b49b-d305f8fe0af8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "dddabe2e-2289-4b4b-a2fc-1b5d8b82f030", "name": "tr(r:p1rdt8167-p1rdt8167lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eb3d4eb-71fc-46f3-b588-d223568c411c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "07bd9128-3c6c-4b6e-a209-1ac8b348eaa9", "name": "tr(r:p1rdt8169-p1rdt8169lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6bdb2cf-9373-4d56-a5f9-cb8fa9c67e55"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6349165a-d47a-4cf4-84f9-df5c5f3a0e98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6349165a-d47a-4cf4-84f9-df5c5f3a0e98"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "3205df5e-6618-4256-9cfd-c5dc7b254caa", "name": "tr(r:p1rdt8174-p1rdt8174lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b0f9433-e0a3-458a-8687-c9cf38d0bbb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4903e82a-8cfb-406e-b4bf-5e01068419a3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4903e82a-8cfb-406e-b4bf-5e01068419a3"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "ae939404-c5bd-43ff-931a-6c0769508bc9", "name": "tr(r:p1rdt8180-p1rdt8180lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c93a476-4ad5-41cd-a07b-e2ccc9ef2c3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8e03b63-853e-4cfe-bf4a-3779b2026637"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8e03b63-853e-4cfe-bf4a-3779b2026637"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "63f53b80-31a5-4067-85a7-637448289748", "name": "tr(r:p1rdt8195-p1rdt8195lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8997dae6-8970-4762-98e9-0617375633d6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "782d6008-7fec-46b6-9461-9e33b79539d3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "782d6008-7fec-46b6-9461-9e33b79539d3"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "ce4d8ec3-56e8-4acc-b3b0-dad1fdf76ef5", "name": "tr(r:p1rdt8201-p1rdt8201lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e3d41a7-06a4-460b-aa6c-3a60c8d2de10"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76e33e4f-05be-44d1-a503-fed82b4da974"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76e33e4f-05be-44d1-a503-fed82b4da974"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "4edc8596-210a-4531-a238-d6738acb9e34", "name": "tr(r:p1rdt9055-p1rdt9055lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "246ad62e-5a10-4031-94e7-1732f58f1da9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c1f6cd8-cde1-45cc-87ca-1355efa38077"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c1f6cd8-cde1-45cc-87ca-1355efa38077"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d20d0070-3f40-4462-90d1-9e42dd91adc4", "name": "tr(r:p1rdt9086-p1rdt9086lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75ee3b24-7407-45ba-94d5-abe187306f13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "afb4c195-8bb6-47d5-88f3-76adb9cda250"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "afb4c195-8bb6-47d5-88f3-76adb9cda250"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "766f3347-7aa4-4383-9703-9c0be50e9d7a", "name": "tr(r:p1rdt16394-p1rdt16394lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5b51836-1807-4fab-b877-94a62021569f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40b03cbe-470d-493a-854a-900557ac20c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40b03cbe-470d-493a-854a-900557ac20c8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "40c5e673-05ab-4012-9c8c-7bf871603311", "name": "tr(r:p1rdt16404-p1rdt16404lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61d5dee2-30f8-434d-8c03-76bccff72549"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38b0bd7c-0898-497f-bb24-4add0fd92932"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38b0bd7c-0898-497f-bb24-4add0fd92932"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "e4a24b59-1b02-49fe-8ef5-030327f3023e", "name": "tr(r:p1rdt16424-p1rdt16424lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "18e3da78-83fc-4b8e-9d45-41adb9b753ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23775c66-0b90-443d-8566-491405876e9d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23775c66-0b90-443d-8566-491405876e9d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "484f938d-d59b-4115-9cb2-2685a7b7a2cd", "name": "tr(r:p1rdt16427-p1rdt16427lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d50d3e76-470b-47c2-ada2-da944962b322"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "980376ed-54fd-434c-b58e-0bbd6eaa9954"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "980376ed-54fd-434c-b58e-0bbd6eaa9954"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "449a26bb-c9e0-421e-b94b-a44f94290b59", "name": "tr(r:p1rdt16603-p1rdt16603lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5a9e0f5-d824-4a76-a4f0-88aab072280e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26bc650a-6838-4320-8afa-b8d2f22e96e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26bc650a-6838-4320-8afa-b8d2f22e96e8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "793b342a-db39-473d-bd79-9522eb670aa7", "name": "tr(r:p1rdt16604-p1rdt16604lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98a946e8-3c8a-49ec-be8a-5610c7fc596c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d31da07-e20a-4fb8-95f4-d91450395471"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d31da07-e20a-4fb8-95f4-d91450395471"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4f26c64f-b8eb-4b58-bb0c-13d80ceb0d14", "name": "tr(r:p1rdt16787-p1rdt16787lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4bc644c-9875-4846-8b0f-dfa0568de623"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4a3b828-bddf-4314-b9a5-03b9dfcd2618"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4a3b828-bddf-4314-b9a5-03b9dfcd2618"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "76b84fae-6335-4869-b08d-8984583dd282", "name": "tr(r:p1rdt16790-p1rdt16790lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4774ed1a-85ec-4ca0-8e9a-3b232588fb0c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c261090-bc22-4d81-9a9e-75227cd7c99e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c261090-bc22-4d81-9a9e-75227cd7c99e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "857e2066-6f60-4b44-8d3c-02354b5fd872", "name": "tr(r:p1rdt16847-p1rdt16847lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e35a4f7-19c1-4f59-9adc-b267f6088264"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1abef1d-4ffc-4696-91ca-e81ac36cce61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1abef1d-4ffc-4696-91ca-e81ac36cce61"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "383a2c28-1707-4345-a2fd-dd5fc492cc54", "name": "tr(r:p1rdt16911-p1rdt16911lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "725fbd98-74ba-4143-8947-da9fdc209889"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0df1550a-7e69-42e9-8059-3a36ecb3d253"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0df1550a-7e69-42e9-8059-3a36ecb3d253"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a2ab4202-af90-45ce-b38a-724c78d23cda", "name": "tr(r:p1rdt7711-p1rdt7711lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2131350-dc34-4d8d-8c9f-c29e25bc654c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64b60527-0853-4973-8d7a-78ba5e377799"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "d0a1b468-f2c0-460e-b454-e11535f6f969", "name": "tr(r:p1rdt8473-p1rdt8473lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3a83211-0829-4e2c-b618-3f1fcaba3e87"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "439728c5-fee5-4dfa-9894-261ba6c40e95"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "6ebf15d5-5f87-45c8-b7ce-35edd541c885", "name": "tr(r:p1rdt6028-p1rdt6028lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e39cb1db-d6a6-4b6c-bc73-920e0c34c292"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35f6f747-811d-4fe2-a9c7-991248572c74"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "df70495a-02d7-450a-9a65-9e0b6b42b83f", "name": "tr(r:p1rdt9478-p1rdt9478lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c49b6e87-5834-4e7e-a64c-b4ec0f7d4995"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddf38626-1223-429f-a903-98f1c975020b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "c3da3337-5527-44f4-b208-3bbfe346a0fe", "name": "tr(r:p1rdt6232-p1rdt6232lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b59ad93a-cca2-4a77-8515-a645ddd2a320"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e2630e1-a215-4740-9327-fa004e89863d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "68bf215e-2a75-42a5-be1c-54396a95a2cf", "name": "tr(r:p1rdt8493-p1rdt8493lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfb41891-7063-44b8-9286-1fe763e49924"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c330731a-fd2c-40c7-8fce-94f7e17cf6d9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "21c9d6f7-778e-45ae-9eee-c04828838596", "name": "tr(r:p1rdt93-p1rdt93lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "900d49ce-4834-4f99-8d74-a5e9d2f63ea0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0921e58d-1ada-4556-8b01-8f22d3bf4ee2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0921e58d-1ada-4556-8b01-8f22d3bf4ee2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "4987fad3-04f3-4a44-9e95-4c76bb8da481", "name": "tr(r:p1rdt99-p1rdt99lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "092a9d51-a39c-4c05-905e-93fb1ae96ba2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef6be92d-5d1b-40e2-a2c2-9d0c1f0bf596"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef6be92d-5d1b-40e2-a2c2-9d0c1f0bf596"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "66884d82-d8ad-43ea-b952-5bef9472cc31", "name": "tr(r:p1rdt101-p1rdt101lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d8e5d83-cd9c-4527-9eef-6219c98dfe93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1277a701-9fbd-4853-a809-962475e016c4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1277a701-9fbd-4853-a809-962475e016c4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "b91fce2e-6543-43ed-b024-f99717df76a9", "name": "tr(r:p1rdt108-p1rdt108lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e61ce952-a643-45aa-a466-8aa15ecceb48"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3aa8d6f2-8d84-42d6-8e7b-89e3b1efa03c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3aa8d6f2-8d84-42d6-8e7b-89e3b1efa03c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "d4442785-5a57-40fb-9428-4491355af6e1", "name": "tr(r:p1rdt6121-p1rdt6121lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2390c014-d418-4d63-8438-529a036487db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "448cc5e0-391f-4a6b-8199-25cef4593edf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "448cc5e0-391f-4a6b-8199-25cef4593edf"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "59985662-1964-4761-9713-7d3f9e638929", "name": "tr(r:p1rdt6123-p1rdt6123lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17f807ba-6ad6-4fd9-9dd0-2c0bacea5b24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e81ba94-5857-42e4-aeee-58542cef0fb6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e81ba94-5857-42e4-aeee-58542cef0fb6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "afa627b8-bda7-4883-9053-6fe4ad39ebd2", "name": "tr(r:p1rdt8017-p1rdt8017lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6378abd-969e-4ec8-93eb-2cc39cdb18eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8428de0e-4b06-4f19-bffb-5fed32f96f67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8428de0e-4b06-4f19-bffb-5fed32f96f67"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "101e3b64-572d-4af1-b520-d6b982c7e99e", "name": "tr(r:p1rdt8043-p1rdt8043lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "691c1909-3b71-4e07-abf0-95aaabfa23bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a367e687-b29a-44b4-a943-7b94762e549e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a367e687-b29a-44b4-a943-7b94762e549e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b52a1ec1-eb6d-4410-9a09-fb90b84cc806", "name": "tr(r:p1rdt8065-p1rdt8065lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "862f3566-9443-4b82-8f05-c994581e131a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8bb025c5-31eb-4771-b433-e1dcad03b3ed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8bb025c5-31eb-4771-b433-e1dcad03b3ed"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ac790f59-9dc9-42c3-b7b0-7e682faa07f7", "name": "tr(r:p1rdt8068-p1rdt8068lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f5fbb8b-0c32-4aa7-acaf-7ea2b5e56505"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd01eed6-0e70-42e7-ac29-4bfd2f70366a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd01eed6-0e70-42e7-ac29-4bfd2f70366a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a999665e-c3af-4abd-a73a-56e5afe42a96", "name": "tr(r:p1rdt8070-p1rdt8070lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473520c7-0098-4bc2-a46f-07efd6c3759c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0bcd460-ccf2-42ee-83c6-bada397ab4d6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0bcd460-ccf2-42ee-83c6-bada397ab4d6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "ff4316bf-2fdf-402e-933a-1d92eec8d30e", "name": "tr(r:p1rdt8190-p1rdt8190lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a761aef-a766-40e2-b8d7-e5a918cece18"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f21f4e99-8877-4bb0-9956-9240bc6db3d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f21f4e99-8877-4bb0-9956-9240bc6db3d1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1fa55d6c-fec8-4ebc-baad-a862692ee4e1", "name": "tr(r:p1rdt8204-p1rdt8204lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa2342e6-2d40-424a-830c-a84af4632b6e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d12bf6fb-8dac-4729-bcda-1ee61c63f6e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d12bf6fb-8dac-4729-bcda-1ee61c63f6e8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "029066e1-edb3-4a44-997d-76fbe7264dd0", "name": "tr(r:p1rdt8208-p1rdt8208lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e2b4d77-2388-4897-86fe-06409fa9d222"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ecf11723-eb6d-423c-ac0c-85fa2d1ba846"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ecf11723-eb6d-423c-ac0c-85fa2d1ba846"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6a8d6f6f-b19a-43dc-a86f-18dfc67b7451", "name": "tr(r:p1rdt8578-p1rdt8578lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb866499-9e9c-4394-bd76-d4320ba4934b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1a593e3-4735-47d2-b893-dd2d07c3c47c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1a593e3-4735-47d2-b893-dd2d07c3c47c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1a547192-d0a9-4174-8c47-f8a34d6a8321", "name": "tr(r:p1rdt8583-p1rdt8583lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dbb79e10-21ba-4f04-b8a3-0cf711d26d40"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "134bac3d-5b7e-48d7-950e-01e5b7d43852"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "134bac3d-5b7e-48d7-950e-01e5b7d43852"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d5409af6-e60a-4f61-af90-35c4c7a32310", "name": "tr(r:p1rdt8584-p1rdt8584lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b601580-3091-4d8c-9718-1367c7ed385f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8ba1042-fcfd-47a8-aa0f-8b13618d3212"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8ba1042-fcfd-47a8-aa0f-8b13618d3212"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "21bda883-4037-4b29-95fc-2e5d0c901e4e", "name": "tr(r:p1rdt10491-p1rdt10491lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4737e613-8cf5-45d7-a3f5-71af051ece4c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8f14e6e-ee96-4ae9-86ba-4a07cf103b65"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8f14e6e-ee96-4ae9-86ba-4a07cf103b65"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482", "name": "", "limit_type": "max", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "base"}}, "value": {"value": 600.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}}, {"uuid": "d17ac250-39de-4755-ab93-d93c9ffec1f4", "name": "3974db24-e8e2-4dea-b6b3-1ce29ed132c9", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 1200.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "33fd2b05-630e-42ac-9ccf-60a8ee3f45c9", "name": "7273acf0-19b9-4e4c-b23c-268bdb215a51", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 900.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "14ee131a-95b9-49c5-b11d-450705732a22", "name": "51a33b90-9eee-4646-b0aa-862f7255c6b3", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 165.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "6ba5defb-3101-4ef8-8d06-36719f7dad94", "name": "27d4ced8-b2f8-4ebb-af19-64e0d6a72831", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 151.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "fa89ef5e-f965-457f-a553-4831f61b03c7", "name": "c53fbbfe-4cda-4768-ab94-259d70acb568", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 301.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "cbd826fb-5ba3-44b3-9c68-e5792dbd9854", "name": "62927506-2fbe-4764-b56a-e2ec536f5a4d", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 205.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "99530725-fc4c-4216-8e67-a4469035c280", "name": "0c3473a8-3f24-4fba-b819-b37916068d57", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 295.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523", "name": "179bf9a8-7aaa-4d22-8e36-ca540eaba4ff", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 325.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "fc796329-2b2a-43b9-80c9-88427ef9b994", "name": "0806190a-92f7-42c1-b527-04504919e640", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 233.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "4900e609-ebb1-44db-852b-602449095f15", "name": "5df7dfb1-43ab-41a2-9a13-560098cbf260", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 205.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "40a26197-da2a-4e22-a50a-3922efd7762c", "name": "08f3b6b5-1bbd-40e6-8b34-a1d59d7b57e2", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0412]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.7627]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[7.69673]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 165.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "3baa725a-9b39-45f8-86af-c6afda2cdf9f", "name": "92be5f47-025f-41ac-a0e4-09323ff980fd", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "2419ddcd-627b-4faa-9878-65d4baf7d064", "name": "c9f25e4e-fbf4-4152-a503-2fdd1553b4c9", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "ab2720f4-bdaa-4e93-a718-9d3398ce76a4", "name": "840ea5ca-ca79-4640-abfc-a248810bef2f", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 301.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "c01372a2-4296-4877-a1f3-dd8c06d37f74", "name": "f3d3a255-32e5-4fb0-9516-d898bf9ec850", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 370.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "42f228c5-d3cc-4ea7-9d1c-029acf33213c", "name": "3p_oh_code_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.22464633333333334, 0.05016533333333334, 0.05016533333333334], [0.05016533333333334, 0.22464633333333334, 0.05016533333333334], [0.05016533333333334, 0.05016533333333334, 0.22464633333333334]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.631065, 0.188089, 0.188089], [0.188089, 0.631065, 0.188089], [0.188089, 0.188089, 0.631065]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[2.8000000000000003, -0.6, -0.6], [-0.6, 2.8000000000000003, -0.6], [-0.6, -0.6, 2.8000000000000003]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 480.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "72184ad1-d36c-4223-8c4b-6bdd0563907c", "name": "breaker_13kv_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1e-05, 0.0, 0.0], [0.0, 1e-05, 0.0], [0.0, 0.0, 1e-05]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1e-05, 0.0, 0.0], [0.0, 1e-05, 0.0], [0.0, 0.0, 1e-05]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[2.8000000000000003, -0.6, -0.6], [-0.6, 2.8000000000000003, -0.6], [-0.6, -0.6, 2.8000000000000003]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 1200.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "9faab192-2f24-4afc-9a9c-210e7b431e38", "name": "breaker_69kv_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1e-05, 0.0, 0.0], [0.0, 1e-05, 0.0], [0.0, 0.0, 1e-05]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1e-05, 0.0, 0.0], [0.0, 1e-05, 0.0], [0.0, 0.0, 1e-05]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[2.8000000000000003, -0.6, -0.6], [-0.6, 2.8000000000000003, -0.6], [-0.6, -0.6, 2.8000000000000003]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 900.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0", "name": "1p_oh_al_4_periwinkle_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.7609666666666666, 0.3959666666666668], [0.3959666666666668, 1.7609666666666666]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.6698333333333334, 0.5686333333333333], [0.5686333333333333, 0.6698333333333334]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[36.92503333333334, -17.558966666666667], [-17.558966666666667, 36.92503333333334]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934", "name": "1p_oh_al_4/0_zuzara_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.4728, 0.20209999999999997], [0.20209999999999997, 0.4728]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.21353333333333335, 0.12473333333333335], [0.12473333333333335, 0.21353333333333335]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[41.3578, -20.447400000000002], [-20.447400000000002, 41.3578]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580", "name": "1p_oh_al_2/0_rucina_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.7166333333333332, 0.28753333333333336], [0.28753333333333336, 0.7166333333333332]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.28883333333333333, 0.1932333333333333], [0.1932333333333333, 0.28883333333333333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[39.3595, -19.342100000000002], [-19.342100000000002, 39.3595]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "2d347746-0969-4a8a-b986-c40ef4f4c015", "name": "1p_oh_al_2/0_rucina_2_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.7166333333333332, 0.28753333333333336], [0.28753333333333336, 0.7166333333333332]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.28883333333333333, 0.1932333333333333], [0.1932333333333333, 0.28883333333333333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[39.3595, -19.342100000000002], [-19.342100000000002, 39.3595]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 300.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f", "name": "1p_ug_al_1/0_brenau_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.9149, 0.3744], [0.3744, 0.9149]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.4972667, 0.3969667], [0.3969667, 0.4972667]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[36.4998, -16.313099999999995], [-16.313099999999995, 36.4998]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 205.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "09abe480-4eaa-43f7-a172-88856f758284", "name": "1p_oh_al_2/0_rucina_2_5", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.7166333333333332, 0.28753333333333336], [0.28753333333333336, 0.7166333333333332]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.28883333333333333, 0.1932333333333333], [0.1932333333333333, 0.28883333333333333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[39.3595, -19.342100000000002], [-19.342100000000002, 39.3595]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 233.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "3c9c08f9-58e9-4367-aee8-72788caa6a7c", "name": "1p_ug_al_2/0_converse_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.7793333, 0.3503333], [0.3503333, 0.7793333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.4209333, 0.3231333], [0.3231333, 0.4209333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[37.42527, -17.11183], [-17.11183, 37.42527]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 233.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398", "name": "1p_ug_al_4/0_sweetbriar_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.5462333, 0.2755333], [0.2755333, 0.5462333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.2976, 0.2043], [0.2043, 0.2976]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[39.3278, -18.6046], [-18.6046, 39.3278]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 301.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "97e8fcf2-7304-40bf-ae9b-e7cdd37a4fb7", "name": "1p_oh_al_4/0_zuzara_2_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.4728, 0.20209999999999997], [0.20209999999999997, 0.4728]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.21353333333333335, 0.12473333333333335], [0.12473333333333335, 0.21353333333333335]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[41.3578, -20.447400000000002], [-20.447400000000002, 41.3578]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 165.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "52d0c8fb-a66f-4033-93f4-79e9ae946d79", "name": "1p_oh_al_2/0_rucina_2_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.7166333333333332, 0.28753333333333336], [0.28753333333333336, 0.7166333333333332]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.28883333333333333, 0.1932333333333333], [0.1932333333333333, 0.28883333333333333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[39.3595, -19.342100000000002], [-19.342100000000002, 39.3595]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 165.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137", "name": "1p_oh_al_acsr_#2_sparrow_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0412]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.7627]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[7.69673]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 165.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "1369a137-ea26-496f-a49e-07fe1c36db1c", "name": "1p_ug_al_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.9176999999999998]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.9546999999999999]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[158.492]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 151.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "6148f90f-6cfa-4038-a641-2905e51ba219", "name": "3p_oh_al_acsr_4/0_penguin_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.3635667, 0.09006667, 0.09006667], [0.09006667, 0.3635667, 0.09006667], [0.09006667, 0.09006667, 0.3635667]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.6385333, 0.2202333, 0.2202333], [0.2202333, 0.6385333, 0.2202333], [0.2202333, 0.2202333, 0.6385333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[7.4482669999999995, -3.1846329999999994, -3.1846329999999994], [-3.1846329999999994, 7.4482669999999995, -3.1846329999999994], [-3.1846329999999994, -3.1846329999999994, 7.4482669999999995]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 325.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "39368021-558c-46e1-b3b2-1376e7863046", "name": "3p_ug_al_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.3289333, 0.05923333, 0.05923333], [0.05923333, 0.3289333, 0.05923333], [0.05923333, 0.05923333, 0.3289333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.9076, 0.6647, 0.6647], [0.6647, 0.9076, 0.6647], [0.6647, 0.6647, 0.9076]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[120.289, -59.026, -59.026], [-59.026, 120.289, -59.026], [-59.026, -59.026, 120.289]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 295.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9", "name": "3p_ug_al_350kcmil_3_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.3388667, 0.1744667, 0.1744667], [0.1744667, 0.3388667, 0.1744667], [0.1744667, 0.1744667, 0.3388667]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.5126, 0.2912, 0.2912], [0.2912, 0.5126, 0.2912], [0.2912, 0.2912, 0.5126]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[164.36499999999998, -81.63499999999999, -81.63499999999999], [-81.63499999999999, 164.36499999999998, -81.63499999999999], [-81.63499999999999, -81.63499999999999, 164.36499999999998]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 370.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "3bc006be-04ae-45f9-8629-fd4cc42dcf20", "name": "3p_oh_al_acsr_1033kcmil_curlew_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.0871, 0.0296, 0.0296], [0.0296, 0.0871, 0.0296], [0.0296, 0.0296, 0.0871]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.5382333, 0.1839333, 0.1839333], [0.1839333, 0.5382333, 0.1839333], [0.1839333, 0.1839333, 0.5382333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[8.6745, -3.8842, -3.8842], [-3.8842, 8.6745, -3.8842], [-3.8842, -3.8842, 8.6745]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 960.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "5c14e22a-39e2-4cbb-9aec-056684ef40fa", "name": "padswitch_1_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 165.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "b97451c9-daac-45bb-a300-842ddcc87c76", "name": "padswitch_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 151.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "71edde96-3e63-4b16-8a12-0f7c3c2771f1", "name": "padswitch_1_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 301.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "6b25b103-d37c-42ce-9c2a-4fed44a4146e", "name": "padswitch_1_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 205.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "b8abe50a-d021-449e-a17c-f73c1142aee4", "name": "padswitch_3_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.499563, -0.1093613, -0.1093613], [-0.1093613, 3.499563, -0.1093613], [-0.1093613, -0.1093613, 3.499563]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 295.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "140f67fe-0cf8-45a3-8e1d-7cd225dab6f1", "name": "padswitch_3_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.499563, -0.1093613, -0.1093613], [-0.1093613, 3.499563, -0.1093613], [-0.1093613, -0.1093613, 3.499563]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 325.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "6ef66588-c56f-4ab4-8152-a7ceffd19280", "name": "padswitch_3_8", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.499563, -0.1093613, -0.1093613], [-0.1093613, 3.499563, -0.1093613], [-0.1093613, -0.1093613, 3.499563]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 233.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "e6fb8431-c064-4a3e-8d04-97f3fe67c4bb", "name": "padswitch_3_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.499563, -0.1093613, -0.1093613], [-0.1093613, 3.499563, -0.1093613], [-0.1093613, -0.1093613, 3.499563]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 205.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "bb659552-de29-4980-948f-b0934dad487c", "name": "fuse_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 325.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "7428d9ad-6003-41e1-acc5-c6e01cb8cae2", "name": "fuse_1_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 165.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "dc9b42df-2b7f-4193-8152-ae871c971371", "name": "fuse_1_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "a0d4e32b-8224-4708-b512-715f8a126cff", "name": "fuse_1_6", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 295.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "1afe4efd-d8e8-446b-970c-e6ba75da4e22", "name": "fuse_1_9", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 233.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "0fcbf486-ed39-4481-96a7-243f013e9f46", "name": "padswitch_1_4", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "b8590a64-3624-43d1-8279-40a7928d98a9", "name": "padswitch_3_6", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.499563, -0.1093613, -0.1093613], [-0.1093613, 3.499563, -0.1093613], [-0.1093613, -0.1093613, 3.499563]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "1cf20eb0-ac1f-4a6f-882e-a5d94dfb8dcb", "name": "padswitch_3_9", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.499563, -0.1093613, -0.1093613], [-0.1093613, 3.499563, -0.1093613], [-0.1093613, -0.1093613, 3.499563]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 301.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "bf5bc40f-4332-47bf-baf6-f15771c7e420", "name": "padswitch_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.499563, -0.1093613, -0.1093613], [-0.1093613, 3.499563, -0.1093613], [-0.1093613, -0.1093613, 3.499563]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 370.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "39499f7e-f729-4218-afda-ccccc72332f9", "name": "fuse_1_5", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 370.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b", "name": "3p_ug_al_3_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.445, 0.1745, 0.1745], [0.1745, 0.445, 0.1745], [0.1745, 0.1745, 0.445]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.5326, 0.2912, 0.2912], [0.2912, 0.5326, 0.2912], [0.2912, 0.2912, 0.5326]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[145.291, -72.088, -72.088], [-72.088, 145.291, -72.088], [-72.088, -72.088, 145.291]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 285.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "e7b097f2-bcb0-4abe-b9b3-be9ec78c74f4", "name": "", "__metadata__": {"fields": {"module": "gdm.distribution.curve", "type": "TimeCurrentCurve", "serialized_type": "base"}}, "curve_x": {"value": [2.0, 2.1, 3.0, 4.0, 6.0, 22.0, 50.0], "units": "ampere", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Current", "serialized_type": "quantity"}}}, "curve_y": {"value": [300.0, 100.0, 10.1, 4.0, 1.4, 0.1, 0.02], "units": "second", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Time", "serialized_type": "quantity"}}}}, {"uuid": "d467095a-575e-4fb7-991f-4e2cdf643318", "name": "56320575-cdcc-4544-a3e7-3bcae477af01", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 325.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}, "delay": {"value": 0.0, "units": "second", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Time", "serialized_type": "quantity"}}}, "tcc_curve": {"__metadata__": {"fields": {"module": "gdm.distribution.curve", "type": "TimeCurrentCurve", "serialized_type": "composed_component", "uuid": "e7b097f2-bcb0-4abe-b9b3-be9ec78c74f4"}}}}, {"uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770", "name": "f7b2bfa1-8c77-4b62-850d-04620d3799e4", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 165.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}, "delay": {"value": 0.0, "units": "second", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Time", "serialized_type": "quantity"}}}, "tcc_curve": {"__metadata__": {"fields": {"module": "gdm.distribution.curve", "type": "TimeCurrentCurve", "serialized_type": "composed_component", "uuid": "e7b097f2-bcb0-4abe-b9b3-be9ec78c74f4"}}}}, {"uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482", "name": "fb7f7907-38db-42f7-a652-427c0c9d518c", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}, "delay": {"value": 0.0, "units": "second", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Time", "serialized_type": "quantity"}}}, "tcc_curve": {"__metadata__": {"fields": {"module": "gdm.distribution.curve", "type": "TimeCurrentCurve", "serialized_type": "composed_component", "uuid": "e7b097f2-bcb0-4abe-b9b3-be9ec78c74f4"}}}}, {"uuid": "861d64ae-aba6-4135-a3ca-f177438722a2", "name": "c44effc4-af4a-4a90-ba5f-b9ab992a2b0c", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 295.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}, "delay": {"value": 0.0, "units": "second", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Time", "serialized_type": "quantity"}}}, "tcc_curve": {"__metadata__": {"fields": {"module": "gdm.distribution.curve", "type": "TimeCurrentCurve", "serialized_type": "composed_component", "uuid": "e7b097f2-bcb0-4abe-b9b3-be9ec78c74f4"}}}}, {"uuid": "ab93cbf0-52fd-4d3d-a7f9-fd7cb4376fa6", "name": "291ce2f8-f492-4cb6-8b07-5df217ca3f92", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 233.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}, "delay": {"value": 0.0, "units": "second", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Time", "serialized_type": "quantity"}}}, "tcc_curve": {"__metadata__": {"fields": {"module": "gdm.distribution.curve", "type": "TimeCurrentCurve", "serialized_type": "composed_component", "uuid": "e7b097f2-bcb0-4abe-b9b3-be9ec78c74f4"}}}}, {"uuid": "73f75b89-55b4-4a16-9fa1-8771daf3d5be", "name": "8d08090f-ee79-4f79-9907-9e6c53c590a3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 370.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}, "delay": {"value": 0.0, "units": "second", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Time", "serialized_type": "quantity"}}}, "tcc_curve": {"__metadata__": {"fields": {"module": "gdm.distribution.curve", "type": "TimeCurrentCurve", "serialized_type": "composed_component", "uuid": "e7b097f2-bcb0-4abe-b9b3-be9ec78c74f4"}}}}, {"uuid": "29ee0e2a-8445-4b4f-89fe-d9e9555d89de", "name": "sb10_p1rhs7_1247_311", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30052484-94f2-43a3-abb7-9314d4593c20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ed5e3889-e8c8-4215-adb8-9880f8937da5"}}}], "length": {"value": 0.001511744, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "42f228c5-d3cc-4ea7-9d1c-029acf33213c"}}}}, {"uuid": "bac6250f-86a5-4f43-ac97-3014374e1458", "name": "sb10_p1rhs7_1247_313", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23779a0d-9859-4591-b4ce-7ec704401d42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1548dd91-bc3d-4a2c-903f-48e11159c558"}}}], "length": {"value": 0.001511744, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "42f228c5-d3cc-4ea7-9d1c-029acf33213c"}}}}, {"uuid": "fdee7cd2-4531-4679-9430-6cddbb1eda85", "name": "sb10_p1rhs7_1247_310", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4d9a6e8-eb1b-454c-ae94-2eb435218fb9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14208aa5-3197-4c90-adf9-3067dae9b5f9"}}}], "length": {"value": 0.002267616, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "42f228c5-d3cc-4ea7-9d1c-029acf33213c"}}}}, {"uuid": "516b4490-8d2f-4ed7-8c42-cc189f1caec0", "name": "sb10_p1rhs7_1247_312", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2427b8de-af1a-44f8-9774-724e635057fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec7726f8-0afb-4c35-8a1b-0691a8fb400d"}}}], "length": {"value": 0.002267616, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "42f228c5-d3cc-4ea7-9d1c-029acf33213c"}}}}, {"uuid": "acbd5efd-6ad5-4648-8703-0efb1a4b5dd9", "name": "sb10_p1rhs7_1247_354", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "001adbd4-6616-4dce-83d2-025e896ada51"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3856ea8d-83da-4d2e-8f66-fae6c69b5db1"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "d17ac250-39de-4755-ab93-d93c9ffec1f4"}}}}, {"uuid": "2e5e0aa8-9e09-438d-b554-36c2e72760e7", "name": "sb10_p1rhs7_1247_307", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c975b603-30a6-4ed1-bbae-696d1c5b0a3d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23779a0d-9859-4591-b4ce-7ec704401d42"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "d17ac250-39de-4755-ab93-d93c9ffec1f4"}}}}, {"uuid": "5ce19f15-a792-442e-a7fa-fac766595642", "name": "sb10_p1rhs7_1247_305", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6263cae0-e97a-4044-a130-e971a626d3c1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30052484-94f2-43a3-abb7-9314d4593c20"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "d17ac250-39de-4755-ab93-d93c9ffec1f4"}}}}, {"uuid": "7c2d9b1a-6e34-47c2-acf6-91b80aa94d66", "name": "sb10_p1rhs7_1247_303", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3856ea8d-83da-4d2e-8f66-fae6c69b5db1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c975b603-30a6-4ed1-bbae-696d1c5b0a3d"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "d17ac250-39de-4755-ab93-d93c9ffec1f4"}}}}, {"uuid": "069db73a-656d-42e0-906b-02395eb7257b", "name": "sb10_p1rhs7_1247_347", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16bb904e-b153-4b0a-97f5-53ad7c6606d8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ca7962b4-686c-4bee-af8d-f1851b835adb"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "33fd2b05-630e-42ac-9ccf-60a8ee3f45c9"}}}}, {"uuid": "a60ebb51-1b37-43c3-859c-de42675fe34f", "name": "sb10_p1rhs7_1247_306", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c975b603-30a6-4ed1-bbae-696d1c5b0a3d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2427b8de-af1a-44f8-9774-724e635057fb"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "d17ac250-39de-4755-ab93-d93c9ffec1f4"}}}}, {"uuid": "ffaf79ca-5c18-46fc-b1af-dc55f22795b8", "name": "sb10_p1rhs7_1247_304", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6263cae0-e97a-4044-a130-e971a626d3c1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4d9a6e8-eb1b-454c-ae94-2eb435218fb9"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "d17ac250-39de-4755-ab93-d93c9ffec1f4"}}}}, {"uuid": "a2e353c7-8d1a-4863-a935-f26557420635", "name": "sb10_p1rhs7_1247_349", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ca7962b4-686c-4bee-af8d-f1851b835adb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "574ab810-c1b0-4662-8c4d-f32ab6893a36"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "33fd2b05-630e-42ac-9ccf-60a8ee3f45c9"}}}}, {"uuid": "ecd0c793-0eab-4a56-992b-f4cdf28c9fb5", "name": "sb10_p1rhs7_1247_302", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3856ea8d-83da-4d2e-8f66-fae6c69b5db1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6263cae0-e97a-4044-a130-e971a626d3c1"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "d17ac250-39de-4755-ab93-d93c9ffec1f4"}}}}, {"uuid": "a596de2d-c583-495c-8e87-684ff992d13b", "name": "l(r:p1rdt4964lv-p1rlv10170)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3541a1a-9680-4baf-9b87-a1322cb1a16a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02e86824-b793-4080-9401-c6995a365baf"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "9679fe35-fbbc-45a3-973d-24b473884602", "name": "l(r:p1rdt4980lv-p1rlv10189)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab731358-e17f-4c48-b6f8-c7bb4c7701de"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58f2b2c3-4f6f-4fd2-abb9-42ff665692bd"}}}], "length": {"value": 0.0491385, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ba04e182-afcb-48fa-9746-2e11559cb473", "name": "l(r:p1rdt4980lv-p1rlv10574)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab731358-e17f-4c48-b6f8-c7bb4c7701de"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b4caeee-6304-4a25-a7d8-44c6014b5e37"}}}], "length": {"value": 0.0298046, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "228b5f7b-dac5-4b0e-b0b1-3a389c3dc040", "name": "l(r:p1rdt4980lv-p1rlv10596)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab731358-e17f-4c48-b6f8-c7bb4c7701de"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aad9ea92-9403-4ac0-9aaf-7e845b8c7bb5"}}}], "length": {"value": 0.0197463, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6c6b3bb5-9c25-4716-a167-aace2b875e2e", "name": "l(r:p1rdt5017lv-p1rlv10262)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0375d197-ccd2-4ed8-9439-857b700cefb8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3317d7c2-2588-426d-91fc-3d765b932da6"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "e4d5b6e9-1c05-4376-8081-8308282a46d2", "name": "l(r:p1rdt5126lv-p1rlv10491)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e33e473-8d5b-4704-bdab-56032991f94e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f7116b9-96c1-42c8-850f-7787f5fd0f96"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "fbef4d18-a197-429d-828d-09390792d6c2", "name": "l(r:p1rdm10619-p1rlv10521)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd4b469b-001b-4914-8e51-e98fe3f6babb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31f26b28-fc9d-4b3d-b204-cf40f3478c44"}}}], "length": {"value": 0.0680764, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "148f5acc-b8c0-4d21-a617-7244a63c718e", "name": "l(r:p1rdm10620-p1rlv10641)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e28a5f3a-4447-469a-85dd-e232d8c6d728"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73ada6ad-ace7-46c1-80f7-2cb33cf4cdb3"}}}], "length": {"value": 0.03407530000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "45d46b87-bb36-48a2-8d53-0a55675034bf", "name": "l(r:p1rdm10619-p1rdm10620)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd4b469b-001b-4914-8e51-e98fe3f6babb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e28a5f3a-4447-469a-85dd-e232d8c6d728"}}}], "length": {"value": 0.0178464, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f38d4a07-13c3-4b95-ae7c-7c6b7d041360", "name": "l(r:p1rdm10619-p1rdt5140lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f114a56-98d7-4fe8-b0b1-b8c4bc791cf9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd4b469b-001b-4914-8e51-e98fe3f6babb"}}}], "length": {"value": 0.0178464, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "2d347746-0969-4a8a-b986-c40ef4f4c015"}}}}, {"uuid": "d351709b-972b-4d55-8d6e-f82dce2d848d", "name": "l(r:p1rdm10621-p1rlv20071)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e09d217e-44a5-4013-8d48-8546d6bb1dc3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07f95ba5-92dd-465f-a38d-8e878243262b"}}}], "length": {"value": 0.0125414, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6b760518-573f-4b9d-a363-83b3bb356359", "name": "l(r:p1rdm10621-p1rdt5140lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f114a56-98d7-4fe8-b0b1-b8c4bc791cf9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e09d217e-44a5-4013-8d48-8546d6bb1dc3"}}}], "length": {"value": 0.0178464, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ec0ee5c6-d17f-48f6-bfe3-c14274d5bfb6", "name": "l(r:p1rdt5142lv-p1rlv10523)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e071635-4071-470d-be09-4484cb90441a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35d47036-a044-4c67-b5b5-0006e2a3b68e"}}}], "length": {"value": 0.019072, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8bc645f7-1f0e-434d-bacc-53e73e4258fe", "name": "l(r:p1rdt5142lv-p1rlv10616)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e071635-4071-470d-be09-4484cb90441a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a5717e0-080e-46ae-918a-64fe4fcba5d7"}}}], "length": {"value": 0.019072, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "587cec7d-7000-4cf3-9010-3f39f71a3747", "name": "l(r:p1rdt5153lv-p1rlv10538)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ec20ad2-b04f-43fc-ad8d-d41746549a57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a302271d-4cf3-45ff-9308-b9cf31fbefa3"}}}], "length": {"value": 0.052564700000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "ebfd9db5-3ac9-4827-98f7-d190caca7cdf", "name": "l(r:p1rdt5153lv-p1rlv10586)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ec20ad2-b04f-43fc-ad8d-d41746549a57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfbe5665-c020-455a-addc-d3f9514735ed"}}}], "length": {"value": 0.0379881, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "d76eb6de-93b6-410f-955e-c8305a62dbe6", "name": "l(r:p1rdt5153lv-p1rlv10610)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ec20ad2-b04f-43fc-ad8d-d41746549a57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b91354e-ce50-44d0-a959-fa451bb9cf20"}}}], "length": {"value": 0.0253548, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "7f0e2518-b943-445a-b36b-df23de1add14", "name": "l(r:p1rdt5155lv-p1rlv10540)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85351f49-cb19-4f71-a6ae-a21f5a48af6f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4829cd2f-7e61-4386-89ce-89d77d5ef5cf"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "5e07c049-b3d7-4d1a-9c10-f0144ef0ecfe", "name": "l(r:p1rdt5159lv-p1rlv10544)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba7e3a6b-f62f-432f-afe7-2ebbfc9abd59"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c722b89-fdaf-416f-863e-02b443375ba1"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "082ef98e-736d-4b9d-8761-8e1f28430622", "name": "l(r:p1rdt5172lv-p1rlv10563)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48efdcb9-083c-4e17-a1d2-acb1388f085e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8a10822-398f-441e-a5ca-73303d832183"}}}], "length": {"value": 0.0709049, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "de3f7150-cc4b-4cdd-8586-d90b3e9f0791", "name": "l(r:p1rdt5179lv-p1rlv10573)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd4155b2-ca55-41d7-bd35-98a5eec8c39a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94677ede-fd5c-4fbb-bfcd-98cf67b56913"}}}], "length": {"value": 0.0550518, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3957c039-612c-45ec-869b-4310f9d481bb", "name": "l(r:p1rdt5179lv-p1rlv10583)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd4155b2-ca55-41d7-bd35-98a5eec8c39a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0431d17-75da-48c1-965c-875f61b0e9bf"}}}], "length": {"value": 0.0550518, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0997b3ce-c275-4e58-aafb-272b62d6c6b6", "name": "l(r:p1rdt5180lv-p1rlv10576)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae26acb3-c2c9-479c-9d19-c30bf00aa8c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25141e20-0a65-4905-b37f-954ed1a8751c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "e5f30957-f466-42ef-b23f-40321acb3168", "name": "l(r:p1rdt5183lv-p1rlv10582)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bbde2e8-42c0-486b-9759-78898d177f93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdfa726f-5606-4ae2-b358-ad664dd7b0e3"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b6b313aa-24d6-40ba-afd6-6230958c1568", "name": "l(r:p1rdt5184lv-p1rlv10589)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1656cc28-8a5b-40da-887f-25605dd336aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53019a8a-b453-4add-9d2d-e4ab380fce67"}}}], "length": {"value": 0.0161579, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "55582f95-1e69-4d6b-b0db-f4b4992538e3", "name": "l(r:p1rdt5184lv-p1rlv10600)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1656cc28-8a5b-40da-887f-25605dd336aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "feb19590-c5f4-4982-9e99-20599f08cfe7"}}}], "length": {"value": 0.0127667, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "87f828d3-1f6d-403b-852d-3f8e3c7b7b65", "name": "l(r:p1rdt5184lv-p1rlv10621)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1656cc28-8a5b-40da-887f-25605dd336aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "374d5417-b2c4-4d16-9b91-d2f519921fd8"}}}], "length": {"value": 0.0240219, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3b197939-0e9a-4bb2-97a0-2ba01199fb47", "name": "l(r:p1rdt5195lv-p1rlv10615)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf05c1bb-39cc-48b3-a576-18913e0cff13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b175fcb-d1ee-44eb-8f89-826e40c5db1d"}}}], "length": {"value": 0.00593856, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9cd169ad-8154-4e21-addc-d48efa048977", "name": "l(r:p1rdt5195lv-p1rlv10634)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf05c1bb-39cc-48b3-a576-18913e0cff13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3184f056-3b5f-403d-86a0-f9b28d6bb3e3"}}}], "length": {"value": 0.018580700000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d25b1b60-f739-427b-bb68-d15d2a530266", "name": "l(r:p1rdt5200lv-p1rlv10627)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "03e7bfdb-ff8b-4142-95ef-8d848ff5d2db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32406d7d-51f9-4c16-900b-526985e5f62b"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "1695160c-d7a9-4b56-a36a-9bf4c210266e", "name": "l(r:p1rdt5201lv-p1rlv10629)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8162a8c-5339-4f42-bd7a-b6dbc5ff463b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e183b3e8-d995-4f1e-baee-8d9d4add157e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "91226eb3-4986-4099-afcc-ba8a616753bc", "name": "l(r:p1rdt5202lv-p1rlv10630)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "39eaedd7-75b6-449f-8ff6-6e31f6e74504"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d60a935-dc9b-48ea-8ee7-9b682452035e"}}}], "length": {"value": 0.0271144, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4ab0b458-002d-4941-8fb5-8fa003f96669", "name": "l(r:p1rdt5206lv-p1rlv10637)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "599a2995-33d5-4bcc-8cd3-585ea37577cd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9510bd0-2bba-4522-bfbe-20b94ea400b6"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "24998fa4-29c5-43de-8a56-451bf7088b34", "name": "l(r:p1rdt5218lv-p1rlv10663)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c650eda9-132b-4419-a055-ad68037c7772"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8198c1c5-67e0-49b9-b11a-1f266f7f4bcb"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "4f0bce0b-cec8-4270-90da-19caf6b4f966", "name": "l(r:p1rdt5236lv-p1rlv10720)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f252d81-66ee-40a6-bce7-2891e06b39e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3d48c0e-704d-4205-94a2-ee74be7ae350"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "52f0d3a1-455d-4799-a4f4-b36bd83a3789", "name": "l(r:p1rdt5342lv-p1rlv10955)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e01069aa-388b-4362-9d02-a164f173dc20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75dbf8f0-4cb6-49b7-a2a5-f98e9ff4b8df"}}}], "length": {"value": 0.017914800000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8823cd6f-545e-4acd-bd12-eea1e38174b4", "name": "l(r:p1rdt5342lv-p1rlv11048)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e01069aa-388b-4362-9d02-a164f173dc20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a8fc823-6fe8-4a3b-9437-68aa751f5e3b"}}}], "length": {"value": 0.017914800000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d01caf79-b234-437a-9476-0490ec03d12d", "name": "l(r:p1rdt5472lv-p1rlv11380)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34a1276e-c702-4c69-b7b1-566d400da2de"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f949a06a-817e-4666-95bb-9536ce06a694"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b63446ac-e79f-48cf-b564-dee1da12a798", "name": "l(r:p1rdt5475lv-p1rlv11384)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d181674-9355-488b-8a3f-5b7c844c35a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0c23aea-471f-4d10-9500-1bc14a67d7e7"}}}], "length": {"value": 0.0318484, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "07dc8977-0ddc-41bf-98a9-8dfec5f9d3b4", "name": "l(r:p1rdt5475lv-p1rlv11386)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d181674-9355-488b-8a3f-5b7c844c35a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f512d86-c9d9-4f58-9d5a-418d0732dc94"}}}], "length": {"value": 0.008446400000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9d9f36bf-d24f-4ab2-a186-fcf4cf92cb27", "name": "l(r:p1rdt5475lv-p1rlv11397)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d181674-9355-488b-8a3f-5b7c844c35a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fd316b0-fd98-4193-9c1b-aaa7d92a4284"}}}], "length": {"value": 0.0375424, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f8c8391e-0f26-45c6-aa81-d7d2ebd35f26", "name": "l(r:p1rdt5476lv-p1rlv11385)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0888f4c5-e037-4891-99fb-fd43934ffae0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2115e8bb-fe49-49ad-8687-68feca212557"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "54f88b11-22f1-4b51-9851-8a348fa7f66b", "name": "l(r:p1rdt5477lv-p1rlv11387)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fafd64c3-efe5-4684-b06f-44e4c8555aa4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbca8c57-0da4-4368-9821-7a9ca4282173"}}}], "length": {"value": 0.0726843, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4ecd7eab-ac7e-4a24-ac86-8a3f9931e089", "name": "l(r:p1rdt5478lv-p1rlv11388)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5107bc9c-f463-49f6-a92f-23c5730475e2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12377bf0-f258-4c29-ab26-e938c95ee25c"}}}], "length": {"value": 0.0557394, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "38a0fb7e-0479-4716-ad92-ef062f819e5b", "name": "l(r:p1rdt5478lv-p1rlv11398)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5107bc9c-f463-49f6-a92f-23c5730475e2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97aa01fe-2e60-4617-8c89-d36f425087fe"}}}], "length": {"value": 0.0557394, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b3073021-9bde-4166-9c27-e2551b7120aa", "name": "l(r:p1rdm11569-p1rlv11390)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "004f56b2-ec94-4189-91b8-46b4af22faa6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b6420b1-3456-42fc-9266-c2b84e063cec"}}}], "length": {"value": 0.110315, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "de9801d0-ebc2-474b-85f2-d670474b0d18", "name": "l(r:p1rdm11569-p1rdt5480lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44ac9e38-8ae3-4102-822b-1c638a6c878a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "004f56b2-ec94-4189-91b8-46b4af22faa6"}}}], "length": {"value": 0.0194577, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "be1cb5ab-a890-4c9b-8c5d-ca7990b7fa8b", "name": "l(r:p1rdm11570-p1rlv11401)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8be902f6-4cca-4ce5-9f73-a1f96c65d8ef"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a215d7dd-8081-4355-9c38-4fd3d2c859c7"}}}], "length": {"value": 0.0577794, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c8464817-2597-4ffb-9d58-991b40d0d49f", "name": "l(r:p1rdm11570-p1rdt5480lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44ac9e38-8ae3-4102-822b-1c638a6c878a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8be902f6-4cca-4ce5-9f73-a1f96c65d8ef"}}}], "length": {"value": 0.0194641, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "878ec4a9-cef2-42e8-8ff1-768ea4ee08b7", "name": "l(r:p1rdt5481lv-p1rlv11392)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f213ee9e-6ae7-4e82-9f25-6fc456f45576"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e740a352-ac8f-4ae2-ace3-254fccd7f96f"}}}], "length": {"value": 0.00971421, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "27b93701-b086-409f-b6c4-248ad3a79eab", "name": "l(r:p1rdt5481lv-p1rlv11394)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f213ee9e-6ae7-4e82-9f25-6fc456f45576"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "996d3e44-142c-42fa-bf4f-2bd1777122dd"}}}], "length": {"value": 0.00971421, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d927f88c-f87d-4609-b7d9-3b440a8942a8", "name": "l(r:p1rdt5483lv-p1rlv11395)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a73d544-9f33-49d9-b648-c806addf3c06"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29922f55-f36a-4b9e-8836-5f9dadd641b7"}}}], "length": {"value": 0.0408239, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b45fdc13-573f-4d62-8969-6d807aee8b95", "name": "l(r:p1rdt5485lv-p1rlv11399)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40eaefce-482f-4a89-bec1-2c11bac2bfb7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68a9eead-8197-4e82-a444-2a4544ec9ddb"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "400b640e-346e-4663-9421-ff28dce9686e", "name": "l(r:p1rdt5650lv-p1rlv11671)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28a6e44b-c6c7-4556-b4d8-d55359391c66"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "834a5733-5264-4adf-861a-25e494df3e37"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "2f30c2bf-be3e-4b60-a6e7-231231e94831", "name": "l(r:p1rdt5653lv-p1rlv11674)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38d1de19-1f51-4875-acc2-a75e3d1a290e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "45f2a901-e4f7-4055-a3e2-b60c61d5033e"}}}], "length": {"value": 0.0467126, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f1e52a68-1c9c-4651-b590-c66946bb5bd9", "name": "l(r:p1rdt5656lv-p1rlv11677)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "87e8c57e-67ff-439c-b28b-0fbdbfd62ea6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b2f121a-2202-43c0-8684-81913a5d6ea9"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "cd9590d2-b2ef-45a1-a2a0-7879503ae2da", "name": "l(r:p1rdt5662lv-p1rlv11684)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea73a91a-b052-486e-810b-1a5ad281e07b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02aef971-5f4a-4ca8-aa33-cce34517bd44"}}}], "length": {"value": 0.0429078, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0d0ec938-717a-4694-87b7-c4ffcc8becc4", "name": "l(r:p1rdt5663lv-p1rlv11686)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16a67a88-5d11-4eca-85fe-38c948ad362c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cda8e361-98b6-49bd-a3ff-30a036a3dc6f"}}}], "length": {"value": 0.0119369, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e9a6d297-511a-4374-baa4-5957c5a9660a", "name": "l(r:p1rdm11909-p1rlv15645)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5b71ca5-a7ab-42f7-824a-bc43fc1708cc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "449098c3-4f65-4350-863f-4b7bc1f14493"}}}], "length": {"value": 0.043632500000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1ac2f810-c321-44b7-95e4-0c2294035bca", "name": "l(r:p1rdm11909-p1rdt5663lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16a67a88-5d11-4eca-85fe-38c948ad362c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5b71ca5-a7ab-42f7-824a-bc43fc1708cc"}}}], "length": {"value": 0.0154548, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "367b85dd-74f1-4252-bf45-811d7899bfaa", "name": "l(r:p1rdt5728lv-p1rlv11779)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6d456893-4d89-455a-b1a5-4863aad6293a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0ba1408-17da-4678-8b04-90c616c3fb48"}}}], "length": {"value": 0.0661386, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "fadcfd18-1437-4d57-ae07-5feb2b125a65", "name": "l(r:p1rdt5728lv-p1rlv11783)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6d456893-4d89-455a-b1a5-4863aad6293a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3890375-c01d-44d2-93f9-8d9d60da8852"}}}], "length": {"value": 0.0661386, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f3b9d6c3-246a-4d60-9f2a-b29050a691c1", "name": "l(r:p1rdt5729lv-p1rlv11780)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95f81d7a-a6af-4843-bfa1-002abc7ff870"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e9a574d-9537-417a-a811-e22d84b8ea53"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b41f8809-5b99-439f-9bd6-a6fc8cb47c7c", "name": "l(r:p1rdt5730lv-p1rlv11784)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2dd206bc-965d-46c9-8fdb-8c158c7bba05"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b66df0bc-6159-42fa-bf49-b8ad17d0e6aa"}}}], "length": {"value": 0.0506895, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2c42071d-569c-4f35-8d65-90380f97501d", "name": "l(r:p1rdt5730lv-p1rlv11786)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2dd206bc-965d-46c9-8fdb-8c158c7bba05"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b15fc66-89d9-483b-9c9f-9b0f39a63b29"}}}], "length": {"value": 0.024148300000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2b57623a-601b-4dbd-bc38-661889b37a6b", "name": "l(r:p1rdm12071-p1rlv11781)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64ee7f4c-b91a-4a25-b85d-a91b83777c1f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28fd9f7c-0195-4529-a972-aa60eced47d2"}}}], "length": {"value": 0.0191276, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3d9ddc49-14e7-4dd7-a2c5-d98beb0d3444", "name": "l(r:p1rdm12071-p1rdt5730lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2dd206bc-965d-46c9-8fdb-8c158c7bba05"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64ee7f4c-b91a-4a25-b85d-a91b83777c1f"}}}], "length": {"value": 0.0173818, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8b230ec6-5ef9-47a7-990c-fafb6e26a6c3", "name": "l(r:p1rdt5731lv-p1rlv11782)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e414162-eda7-4cf2-9116-fc24af9461bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "496fc854-bbf8-463b-b16c-12dd1b444cc6"}}}], "length": {"value": 0.0292119, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a73dcae4-6fc0-4b6f-a432-3cb5ef33058b", "name": "l(r:p1rdm12075-p1rlv11785)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7103c2f0-8160-434f-b4b3-edfbd7e97464"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ed0eb774-fcc3-417f-a8a4-fbdb825cc106"}}}], "length": {"value": 0.0190573, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d6dbe381-462c-408e-87b7-e82db0872b88", "name": "l(r:p1rdm12075-p1rdt5731lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e414162-eda7-4cf2-9116-fc24af9461bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7103c2f0-8160-434f-b4b3-edfbd7e97464"}}}], "length": {"value": 0.0194685, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "40793b09-be51-4c19-855d-a9cab1a29975", "name": "l(r:p1rdt5840lv-p1rlv12028)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9974869d-7d87-4a27-9606-076cd7799953"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1dfd848-b639-41b5-ad95-2c03a51bd36b"}}}], "length": {"value": 0.0166971, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "59eddbe0-cc88-4acf-aab0-ee9589891212", "name": "l(r:p1rdt5840lv-p1rlv12157)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9974869d-7d87-4a27-9606-076cd7799953"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc4d79bb-8ba3-4146-9d50-16db48ffec22"}}}], "length": {"value": 0.0166971, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "80b0ac16-51ce-4b22-8d60-68d9d40dc483", "name": "l(r:p1rdt5923lv-p1rlv12214)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "751d2f2e-bb6f-4ca6-9e86-0e2b5ff3f92a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df9d9de2-6929-48a4-a390-c0e2f129b374"}}}], "length": {"value": 0.0436747, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "55166bbd-4d92-45f6-90c8-7e525148435b", "name": "l(r:p1rdt5923lv-p1rlv12217)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "751d2f2e-bb6f-4ca6-9e86-0e2b5ff3f92a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4d26673-c304-41de-8b5b-149552601ba4"}}}], "length": {"value": 0.0140011, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8cba7cbc-61c9-40c7-a472-15ba57ed7cc2", "name": "l(r:p1rdt5923lv-p1rlv12222)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "751d2f2e-bb6f-4ca6-9e86-0e2b5ff3f92a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cee79fe8-f140-4be9-aa6b-d56e37fb6857"}}}], "length": {"value": 0.06246270000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d23744d0-51a4-42f6-a714-7ca8bc4f452a", "name": "l(r:p1rdt5923lv-p1rlv12225)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "751d2f2e-bb6f-4ca6-9e86-0e2b5ff3f92a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8e1f797-9417-447c-8a08-cf00a462ef14"}}}], "length": {"value": 0.0351977, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "5163b09b-32f5-4b89-8d37-f90900ee57a4", "name": "l(r:p1rdt6038lv-p1rlv12538)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d654945d-b71d-4943-86a2-5830fca200c9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b42c2471-9114-4042-980e-dd226ad024a3"}}}], "length": {"value": 0.010266900000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "804e6cda-09e4-439b-b278-de2464a271a4", "name": "l(r:p1rdt6043lv-p1rlv12552)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ae7bbf-f53e-4ae2-8145-bf56ce935094"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c42d772-e2a8-45d4-9cf2-2edd7a567b35"}}}], "length": {"value": 0.0181528, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "b31deec8-a68b-4572-a9fa-62a1124c070a", "name": "l(r:p1rdm12875-p1rlv12553)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3e53a11-6c13-4d27-89f2-2abbd28f69ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a29aec49-62a4-41ec-a67c-a84470a23f7b"}}}], "length": {"value": 0.0385577, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "5ee09bf3-d8ba-4f9e-ae22-905ffbba3cfa", "name": "l(r:p1rdm12875-p1rdt6043lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ae7bbf-f53e-4ae2-8145-bf56ce935094"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3e53a11-6c13-4d27-89f2-2abbd28f69ac"}}}], "length": {"value": 0.0560413, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "d6a45977-5d4a-4d99-a466-58bc7bf18e45", "name": "l(r:p1rdm12876-p1rlv12559)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b748c697-b624-43f0-b375-5024d8cff92b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a47101-b6df-473e-9c7b-96e076c17931"}}}], "length": {"value": 0.0120531, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "09aeebd8-f06b-4d31-bf4d-0e7a60792681", "name": "l(r:p1rdm12877-p1rlv12562)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3082eb6b-1a9f-4b6e-930e-f58173fe02ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b0417d3-820d-4daa-aec5-3dcf34e40e00"}}}], "length": {"value": 0.00937768, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "d8bd73cc-9912-47ad-abdb-98e0f3860f40", "name": "l(r:p1rdm12876-p1rdm12877)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b748c697-b624-43f0-b375-5024d8cff92b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3082eb6b-1a9f-4b6e-930e-f58173fe02ac"}}}], "length": {"value": 0.00528266, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "7b24a598-5dca-4ef9-a2fb-eb6cd38fc84c", "name": "l(r:p1rdm12876-p1rdt6043lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ae7bbf-f53e-4ae2-8145-bf56ce935094"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b748c697-b624-43f0-b375-5024d8cff92b"}}}], "length": {"value": 0.0304331, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "388119d6-f740-4a34-b677-297b11d1d4a9", "name": "l(r:p1rdt6046lv-p1rlv12557)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2e2d1a7-039c-4b29-a061-b814ac675e3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fe4d6ae-cca5-476c-981a-a1dcd27b1e84"}}}], "length": {"value": 0.0315499, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "ee6ada67-4f86-4be6-b132-2aad7bf157f5", "name": "l(r:p1rdt6047lv-p1rlv12558)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21e75ccd-7e21-4f0d-890c-81aa6b33b109"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a427f20-861a-4616-9443-265beaeccca3"}}}], "length": {"value": 0.00804165, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "24ad47a8-99be-4c96-9d61-3961533ba7d0", "name": "l(r:p1rdt6208lv-p1rlv12936)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01be483b-09f4-450e-a39d-78692c40ee8b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "019e419c-9f88-455a-bf48-b89531ed9e51"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "3f467e00-f448-4c36-8cb1-d2229235a0d9", "name": "l(r:p1rdt6221lv-p1rlv12959)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73f78740-2ec5-4ad8-b7fb-40f4a72b730e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8418804f-aad5-49df-9916-f427da5089c1"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "fb81f428-e1d6-442c-82a6-cb1c5af44b3c", "name": "l(r:p1rdt6226lv-p1rlv12971)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3154eee7-a1ba-4b9d-9e91-bab55529d358"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be845651-8e1c-4b6d-8633-fcbdfb1fd5d4"}}}], "length": {"value": 0.0550308, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "209ae9db-43f7-4864-9a91-dd599c660b29", "name": "l(r:p1rdt6226lv-p1rlv20185)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3154eee7-a1ba-4b9d-9e91-bab55529d358"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "646058a3-cda7-4723-bd0f-05d305fe7c11"}}}], "length": {"value": 0.0550308, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "baa087fe-f55d-461e-98a8-a7791ca43e18", "name": "l(r:p1rdt6268lv-p1rlv13043)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72ce0706-6b32-4b4b-9bf3-fd1f5a6af5ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3072c6c-3a40-4e49-bd00-febc8268b135"}}}], "length": {"value": 0.038529200000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c319e0c1-2119-4d87-af76-491d2ce8fdec", "name": "l(r:p1rdt6268lv-p1rlv13047)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72ce0706-6b32-4b4b-9bf3-fd1f5a6af5ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4209bdad-276f-4e07-93e0-78b162ce95cf"}}}], "length": {"value": 0.0748394, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "009b3a8c-9e06-4cda-bc24-d2f036ee33a2", "name": "l(r:p1rdt6268lv-p1rlv13054)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72ce0706-6b32-4b4b-9bf3-fd1f5a6af5ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21c6ea4f-ec9d-424e-8743-7175408f9e2c"}}}], "length": {"value": 0.0369069, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a53a4533-5597-4cc6-9369-c1ea467408b4", "name": "l(r:p1rdt6269lv-p1rlv13044)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79c91fa8-15ad-4e8d-96bd-2cad395dd280"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa31c772-8460-4624-a123-64b87ca8d332"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "bc4eed45-5ff4-4307-bb2c-bb2c0189e21a", "name": "l(r:p1rdt6270lv-p1rlv13045)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5adb2083-3d46-48a7-8996-37c0781b0215"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6070414d-09e7-48a7-aec0-c105cc0f1a93"}}}], "length": {"value": 0.034086700000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8b7550b3-6d1b-4305-af43-5cc86d9bf52f", "name": "l(r:p1rdt6270lv-p1rlv13046)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5adb2083-3d46-48a7-8996-37c0781b0215"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5edc15fb-49d5-4052-8fad-4979578f6ed1"}}}], "length": {"value": 0.0160269, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "09abe480-4eaa-43f7-a172-88856f758284"}}}}, {"uuid": "93980ed3-1b22-488f-8670-d1ef74982523", "name": "l(r:p1rdt6270lv-p1rlv13052)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5adb2083-3d46-48a7-8996-37c0781b0215"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86d59550-d7c8-47e1-a6bc-14b2d50de58c"}}}], "length": {"value": 0.04494170000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "786442b2-02c0-49ce-84bc-697eb42f86e0", "name": "l(r:p1rdt6271lv-p1rlv13048)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1335e64c-9f37-4e73-a37f-8f76737cabff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "569078be-37c2-4c05-8455-91945eb7fdb9"}}}], "length": {"value": 0.0901436, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "559c20cc-21df-4271-8c6c-9082c619342d", "name": "l(r:p1rdt6272lv-p1rlv13049)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04422e0a-1952-422d-a201-5fafef1875db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ed85192-4c5a-4c15-ba21-1ba883b03ddd"}}}], "length": {"value": 0.00941805, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f04b5148-7972-4220-8564-2067c13a4eb3", "name": "l(r:p1rdt6272lv-p1rlv13053)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04422e0a-1952-422d-a201-5fafef1875db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e058437-0138-4305-a33e-d8fa61aed8cc"}}}], "length": {"value": 0.00941805, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2f3c609b-2021-408f-8726-e117aee9d249", "name": "l(r:p1rdm13376-p1rlv13051)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b6739c0-1b15-42c1-9fdd-4d7f604a03ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9a855b0-538e-4fab-91f1-93b4ece09409"}}}], "length": {"value": 0.0533824, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1160992a-885e-46ae-b199-876ea6532f62", "name": "l(r:p1rdm13376-p1rdt6274lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1db8c80-e791-4c31-a6f2-713aa665bf41"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b6739c0-1b15-42c1-9fdd-4d7f604a03ce"}}}], "length": {"value": 0.0171039, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f4585475-d917-4176-9105-3c08f98e6ae2", "name": "l(r:p1rdm13377-p1rlv13056)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e395985-4c66-49c9-9252-94d8078b8e8e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16584dfd-537d-4b0d-a651-c73d0beabc6d"}}}], "length": {"value": 0.04504020000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3415f9bf-f574-44ed-b40d-dde7483331f3", "name": "l(r:p1rdm13377-p1rdt6274lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1db8c80-e791-4c31-a6f2-713aa665bf41"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e395985-4c66-49c9-9252-94d8078b8e8e"}}}], "length": {"value": 0.0171039, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7bd303bc-c877-43d3-92ed-7bf8d2e8223a", "name": "l(r:p1rdt6275lv-p1rlv13055)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba567584-fbee-44eb-b3f1-da24a0ce66a0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387df3d3-5f03-47f4-8b16-bea8815e63d1"}}}], "length": {"value": 0.0150884, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ce961dd6-3068-4529-b5b2-7ae148f76be1", "name": "l(r:p1rdt6275lv-p1rlv13058)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba567584-fbee-44eb-b3f1-da24a0ce66a0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c83997dc-872f-494f-8c8a-7266c854fc48"}}}], "length": {"value": 0.0150884, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f7952fba-5181-4715-84ef-6c47236d1571", "name": "l(r:p1rdt6276lv-p1rlv13057)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f20ace2-5ec8-4451-b7e7-66f46c2c487b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c63d163-75bd-4d91-bcfa-229a2e331b1f"}}}], "length": {"value": 0.0435582, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "de4dd982-2e26-43e0-bd9e-d2a4a732efb1", "name": "l(r:p1rdt6276lv-p1rlv13062)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f20ace2-5ec8-4451-b7e7-66f46c2c487b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d2fa164-4c03-4bcd-a386-749ccd4e9001"}}}], "length": {"value": 0.0435582, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "085a1bfb-ff94-46ab-9c2a-9f9baee7d5e7", "name": "l(r:p1rdt6277lv-p1rlv13059)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e582b04d-a8d8-4ee9-8576-1e5941623c0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a1779b5b-1a6c-4511-9d4b-88026b430173"}}}], "length": {"value": 0.00731377, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "87f20977-ad83-4193-8443-34331741b51d", "name": "l(r:p1rdt6278lv-p1rlv13060)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b37eabc-787a-491f-bc4f-956f43a862ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8767a040-da31-48d9-9473-0941856bcedc"}}}], "length": {"value": 0.0214401, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4863f307-9b70-4638-bfb9-09034f350d4b", "name": "l(r:p1rdt6345lv-p1rlv13185)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a38eb6d-a625-42a1-95f6-bbf078d1447a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c29c3206-b71d-41d1-8ad7-a693c8c25d4d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "422ef105-d242-44fb-a517-c36ddd805f83", "name": "l(r:p1rdt6347lv-p1rlv13187)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e40008af-ff50-42bd-8897-f663c27a436f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ffbd17b6-b1a2-4e55-9052-67a84419bb9d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "f4d53aad-8c53-4280-8a58-e354c3deb985", "name": "l(r:p1rdt6348lv-p1rlv13188)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d84ac329-f314-41be-a2ee-89bc74789a18"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67ffcd9f-ba90-4da7-b3b6-46310e321590"}}}], "length": {"value": 0.0371493, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b9f20c71-b16d-49bc-b80b-42f92cd6aded", "name": "l(r:p1rdt6348lv-p1rlv13191)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d84ac329-f314-41be-a2ee-89bc74789a18"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f6d09e9-3592-4560-8626-0d7cb71ca56a"}}}], "length": {"value": 0.0217677, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "99adfcee-ce5d-4d2a-8a1e-e54a38a2c08d", "name": "l(r:p1rdt6348lv-p1rlv13195)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d84ac329-f314-41be-a2ee-89bc74789a18"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e3e10c6-6ce2-4efa-be50-80e8b9bffe29"}}}], "length": {"value": 0.0257734, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3912c661-e4ef-4616-8d05-3299ab44ff9e", "name": "l(r:p1rdt6348lv-p1rlv13201)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d84ac329-f314-41be-a2ee-89bc74789a18"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cdd7c49-e758-4009-8db5-d0b5748f919c"}}}], "length": {"value": 0.008488610000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3c1adb4d-4ff6-4c8a-8c1a-43251f741964", "name": "l(r:p1rdt6349lv-p1rlv13189)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdfa0310-7dc5-4181-a64e-cc2522370547"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "268361f6-d5ac-4002-80a6-f56f3b33599c"}}}], "length": {"value": 0.0123575, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "59797aff-2413-4c30-b02b-f1d86b4483ea", "name": "l(r:p1rdt6350lv-p1rlv13190)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0138b892-d18e-497c-9857-c4d5676deac2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3dbc593c-3949-4fa4-8738-d92540dbf998"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "5cf6510a-4dea-4772-ad91-0ea898f6570e", "name": "l(r:p1rdt6353lv-p1rlv13194)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "015322ae-7712-488f-9569-33fc785e4f62"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d5ba889-d8f7-44ca-86b2-40939fa95df2"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "3c73b898-fe34-4069-b66a-29eddd852722", "name": "l(r:p1rdm13558-p1rlv13196)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fd10fd1-b67f-422c-b976-582e2bb4e0ec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27013147-3d8f-4d75-a7a7-24457dc6d62a"}}}], "length": {"value": 0.0952802, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d43267bf-c60c-46cf-a3c3-40514c8ed391", "name": "l(r:p1rdm13558-p1rdt6354lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f06a08bd-05ea-4914-b0d0-07cd0e83bfbc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fd10fd1-b67f-422c-b976-582e2bb4e0ec"}}}], "length": {"value": 0.019710700000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b6dc79bc-04b3-4a9d-95f9-39133febe09b", "name": "l(r:p1rdm13559-p1rlv13200)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "786efaf4-c281-4def-9a4e-2ffbf37e08be"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fed30a3f-12a5-4545-b5d5-5c13a131a256"}}}], "length": {"value": 0.0781624, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "336fd466-42ce-4a03-a8b1-500c9b6320ff", "name": "l(r:p1rdm13559-p1rdt6354lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f06a08bd-05ea-4914-b0d0-07cd0e83bfbc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "786efaf4-c281-4def-9a4e-2ffbf37e08be"}}}], "length": {"value": 0.0196968, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3fb850f0-48fc-4d93-9b2f-53099e8c7a93", "name": "l(r:p1rdt6355lv-p1rlv13197)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1d14a79-4d18-43fe-8790-57ea9adf83a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b077d0f-74ec-4a04-8eb8-cf02ad16077d"}}}], "length": {"value": 0.00855264, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7445bde4-f85a-4868-beaa-c9eb3c64ae62", "name": "l(r:p1rdt6356lv-p1rlv13199)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "548724aa-110a-428f-b71a-acdf0051dc39"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad7545fb-8a41-4ed7-a178-e90f19bfa9d5"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "1b5cb726-1c52-4df2-8c39-dd309d7acca2", "name": "l(r:p1rdt6409lv-p1rlv13316)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e36cfaaa-3996-4cc6-aa4f-170f20c5d1e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473b080b-1412-40dc-a452-09d43a462098"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "9e896bae-73ca-433f-9ddc-b981c3e73cf1", "name": "l(r:p1rdt6498lv-p1rlv13597)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "353889fb-da44-4cf8-ae0e-d20541f36d7e"}}}], "length": {"value": 0.0114781, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8553403c-d26e-4b50-8608-cd168ebfbd94", "name": "l(r:p1rdt6498lv-p1rlv13631)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6015a810-79da-480f-b1a1-fd6a4abdba37"}}}], "length": {"value": 0.00314293, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "c01c83bb-3dbc-4882-b0f0-e842930869ba", "name": "l(r:p1rdt6498lv-p1rlv13696)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f92273c9-90b8-4819-b036-9d69afb5aed6"}}}], "length": {"value": 0.0270935, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1b049af0-8fb0-40ee-8c70-d2be4bee9165", "name": "l(r:p1rdt6498lv-p1rlv13702)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fe3c958-296f-4b51-8b2b-74bb34ddb5a6"}}}], "length": {"value": 0.0161535, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d15500ac-94ef-479c-a786-fdd84b84b87e", "name": "l(r:p1rdt6498lv-p1rlv13703)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9efacf5-5b96-4670-b6f1-dc398485cde9"}}}], "length": {"value": 0.0105519, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4fc94db9-da62-43ee-9583-c2c0fd98625c", "name": "l(r:p1rdt6498lv-p1rlv13724)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "457c6c9d-5020-4cf3-9c1e-c36012a619d2"}}}], "length": {"value": 0.0187626, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8091ae42-7ca0-4232-911a-682fa9fb74a3", "name": "l(r:p1rdm13996-p1rlv13598)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce39f1f5-b784-4919-9d3d-f6149f39595e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59953c2f-244e-4bb8-ab24-b28d82b195e1"}}}], "length": {"value": 0.0312105, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "01e418b1-0c88-4fa1-9b60-1516e6ba9401", "name": "l(r:p1rdm13996-p1rlv13626)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce39f1f5-b784-4919-9d3d-f6149f39595e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aeea20e0-9908-4f28-aa5d-068244e3861b"}}}], "length": {"value": 0.045519500000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "166332aa-67ba-485f-93b1-02469f1cdf58", "name": "l(r:p1rdm13996-p1rlv13635)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce39f1f5-b784-4919-9d3d-f6149f39595e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc33013a-6a90-46a7-9127-f32288111c14"}}}], "length": {"value": 0.0353648, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2b8702e0-0e6b-4594-a41c-501c6a9f441d", "name": "l(r:p1rdm13996-p1rlv20504)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce39f1f5-b784-4919-9d3d-f6149f39595e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b3e7495-7732-42ce-8d53-a5f1b7383ce4"}}}], "length": {"value": 0.0518247, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f092bdfa-1b2e-4449-91e0-4c62efc169e0", "name": "l(r:p1rdm13996-p1rdt6499lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb05d831-1556-4f56-8065-d9d16657caa3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce39f1f5-b784-4919-9d3d-f6149f39595e"}}}], "length": {"value": 0.0125057, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0581c111-e821-458c-a17c-100b3ff33c3a", "name": "l(r:p1rdm13999-p1rlv13698)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f85240e6-bbbe-4b90-8419-a00a3ca9613f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3839c291-3f45-46c3-973f-6a9615fcf81b"}}}], "length": {"value": 0.0426193, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "40b10f22-d50a-4135-8e84-81fa97145e9b", "name": "l(r:p1rdm14000-p1rlv13726)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea740eb8-42c6-4417-97d6-7c73f1fc2bc8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "642597e6-fe60-442f-b356-2be6f21677b2"}}}], "length": {"value": 0.00697416, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "072d74a7-35ce-499b-be52-d6ad80a0dc15", "name": "l(r:p1rdm13999-p1rdm14000)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f85240e6-bbbe-4b90-8419-a00a3ca9613f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea740eb8-42c6-4417-97d6-7c73f1fc2bc8"}}}], "length": {"value": 0.0139057, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5f658b70-1fd2-4e3d-ac5c-c7a295a50529", "name": "l(r:p1rdm13999-p1rdt6499lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb05d831-1556-4f56-8065-d9d16657caa3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f85240e6-bbbe-4b90-8419-a00a3ca9613f"}}}], "length": {"value": 0.0125149, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f76f9ba9-1ad5-411f-8fe0-e19d0b125427", "name": "l(r:p1rdt6500lv-p1rlv13613)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a20a4242-8a76-49f3-9bf5-3d7aaf751cdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "216537dd-ea7b-461c-b821-99491c41b7f0"}}}], "length": {"value": 0.0114283, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "ebf5f920-605f-4b2b-9361-25feec533c82", "name": "l(r:p1rdm14004-p1rlv13618)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83aa4266-e486-4e00-a09b-7bcdc613a9b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f823a90c-effd-489c-9e0a-c110ccb7b9e8"}}}], "length": {"value": 0.0123108, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "c92a290b-f056-49ba-b87b-2d53df6805ed", "name": "l(r:p1rdm14007-p1rlv13653)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff282b99-30bb-4c1d-acb9-02fafe241577"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c61a243-7736-46a0-a950-7cc811381158"}}}], "length": {"value": 0.0534886, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "a96b6494-0b33-4e6a-86cf-59557654a321", "name": "l(r:p1rdm14002-p1rlv13599)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c0ae3b1-ac0d-43c9-9a1e-c73bd10e3ad8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2a60818-4310-4100-9aa8-35ef37aa5f40"}}}], "length": {"value": 0.0432926, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "6d4b04c7-dd70-46da-9bc3-430fe1b50bb9", "name": "l(r:p1rdm14005-p1rlv13648)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d576dffc-af75-488e-8c51-19aa726f0505"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62a29ac5-7227-43b2-b602-b1189cc93839"}}}], "length": {"value": 0.0533671, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "6fe861c6-ef06-4253-98a7-6b8afb1cd014", "name": "l(r:p1rdm14002-p1rdm14005)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c0ae3b1-ac0d-43c9-9a1e-c73bd10e3ad8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d576dffc-af75-488e-8c51-19aa726f0505"}}}], "length": {"value": 0.00732814, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "b3bdf82d-ea8f-474c-92c9-d4b35eb23516", "name": "l(r:p1rdm14002-p1rdm14007)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff282b99-30bb-4c1d-acb9-02fafe241577"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c0ae3b1-ac0d-43c9-9a1e-c73bd10e3ad8"}}}], "length": {"value": 0.007327430000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "f5e00887-072c-477b-a27b-8a1bb5b644a1", "name": "l(r:p1rdm14004-p1rdm14007)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83aa4266-e486-4e00-a09b-7bcdc613a9b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff282b99-30bb-4c1d-acb9-02fafe241577"}}}], "length": {"value": 0.007320720000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "3c9c08f9-58e9-4367-aee8-72788caa6a7c"}}}}, {"uuid": "8653ff7a-8098-4538-800a-42481de0aacb", "name": "l(r:p1rdm14004-p1rdt6500lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a20a4242-8a76-49f3-9bf5-3d7aaf751cdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83aa4266-e486-4e00-a09b-7bcdc613a9b5"}}}], "length": {"value": 0.00898801, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "f731ee6a-9af9-40b1-a1a2-dadc871f741c", "name": "l(r:p1rdm14008-p1rlv13687)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e5abf33-75a2-446f-9c6c-1f3384b78c24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4671f981-e26e-4f26-9698-7f9068ce6dec"}}}], "length": {"value": 0.00688001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "c55b8ce0-a116-435e-81c7-4803d454bdde", "name": "l(r:p1rdm14009-p1rlv13719)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "592b8095-ba99-4993-a445-9af51fa89f57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44aa3f37-e0db-4050-b47f-ac14b7fa6534"}}}], "length": {"value": 0.00707054, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "1bfc33e4-b04b-4983-8901-3644068a4e2f", "name": "l(r:p1rdm14006-p1rlv13652)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33445b16-68bf-4606-8ac5-def4763fb95d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3310c14a-d1ee-4d0c-8428-d002703c61d5"}}}], "length": {"value": 0.00737761, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "55929b77-1dd1-4d96-8f47-b2896190c205", "name": "l(r:p1rdm14006-p1rdm14009)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "592b8095-ba99-4993-a445-9af51fa89f57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33445b16-68bf-4606-8ac5-def4763fb95d"}}}], "length": {"value": 0.00898801, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "195330b0-ed90-4511-a59e-4f29b3f0af24", "name": "l(r:p1rdm14008-p1rdm14009)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e5abf33-75a2-446f-9c6c-1f3384b78c24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "592b8095-ba99-4993-a445-9af51fa89f57"}}}], "length": {"value": 0.00898801, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "876bd333-5a47-4e8f-a9b1-cc4abcb2151a", "name": "l(r:p1rdm14008-p1rdt6500lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a20a4242-8a76-49f3-9bf5-3d7aaf751cdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e5abf33-75a2-446f-9c6c-1f3384b78c24"}}}], "length": {"value": 0.017982000000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "3c9c08f9-58e9-4367-aee8-72788caa6a7c"}}}}, {"uuid": "342ef8ad-e444-494e-ad4c-92901121506a", "name": "l(r:p1rdt6501lv-p1rlv13600)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59ab6d81-a91c-4350-8f94-abe02e3e1555"}}}], "length": {"value": 0.0222413, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "390e5cf1-b1e6-49ab-b980-6194c2f0c071", "name": "l(r:p1rdt6501lv-p1rlv13606)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29838633-5c95-4b73-8227-cfa7f4aedc32"}}}], "length": {"value": 0.0135771, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e9b80295-684b-4497-aeca-3ac73bfe04d1", "name": "l(r:p1rdt6501lv-p1rlv13608)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5e8caf4-4d81-4bbd-98df-6622c5ad0563"}}}], "length": {"value": 0.00679883, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5b4b52a4-31e7-4087-bb1e-24c7c491bf3e", "name": "l(r:p1rdt6501lv-p1rlv13619)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f693a1d2-5499-4810-9458-f205eda265fa"}}}], "length": {"value": 0.0334092, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "97e8fcf2-7304-40bf-ae9b-e7cdd37a4fb7"}}}}, {"uuid": "d453bf68-5c20-462a-8a81-469dded3c831", "name": "l(r:p1rdt6501lv-p1rlv13622)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4540b2cb-ee21-4515-a7ca-fbca371f060d"}}}], "length": {"value": 0.0312591, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c582d791-9861-4686-a34a-1a5ee46f781c", "name": "l(r:p1rdt6501lv-p1rlv13637)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30c470ac-39d1-4379-9ae7-790d912bce2c"}}}], "length": {"value": 0.0185945, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "99295cd8-2b7e-4cca-aa16-0b8d909f4c06", "name": "l(r:p1rdm14016-p1rlv13683)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b7d4c6f-98b5-4cec-b8a4-9311b5fc92bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "de45dc59-3e0a-4b33-8cf4-d5213b0140c1"}}}], "length": {"value": 0.0352211, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ca89eb81-8901-400a-9265-f885565a3423", "name": "l(r:p1rdm14016-p1rdt6501lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b7d4c6f-98b5-4cec-b8a4-9311b5fc92bd"}}}], "length": {"value": 0.0288269, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2db45833-0f3f-4f0f-837b-c37add7fd184", "name": "l(r:p1rdt6502lv-p1rlv13601)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7682e9f7-1272-4781-b128-34c7329afe49"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91953a27-bbc7-494a-bec2-a12b4c0f6af6"}}}], "length": {"value": 0.015644, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7c0d2bec-f934-477c-9124-d3536213c299", "name": "l(r:p1rdt6502lv-p1rlv13634)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7682e9f7-1272-4781-b128-34c7329afe49"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "987b05d5-9bb9-434d-98b3-623ee5014870"}}}], "length": {"value": 0.015644, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c18dbc35-bff3-4eed-8032-7a9d865d9cb8", "name": "l(r:p1rdt6505lv-p1rlv13604)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387e7785-8d40-4ddd-8c2b-14a83d4e7401"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9b83bdf-b564-4997-bfc7-1be2f2e58199"}}}], "length": {"value": 0.0220113, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "316eb2e4-da26-4004-9bc7-4f0f810b0c35", "name": "l(r:p1rdt6505lv-p1rlv13605)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387e7785-8d40-4ddd-8c2b-14a83d4e7401"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c39dc6f1-08b5-4bc1-a6ae-be0076af56aa"}}}], "length": {"value": 0.021993400000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c4d7cf80-30b7-49d5-bc93-a33daa9a50b4", "name": "l(r:p1rdt6505lv-p1rlv13654)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387e7785-8d40-4ddd-8c2b-14a83d4e7401"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7be734c-88e2-42c1-8061-f4632bd05759"}}}], "length": {"value": 0.0264068, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2fa21c7c-b71e-481c-8ba0-705b20e1dd84", "name": "l(r:p1rdt6505lv-p1rlv13676)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387e7785-8d40-4ddd-8c2b-14a83d4e7401"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8df1a69e-5b18-4eef-ab60-543a97257297"}}}], "length": {"value": 0.028008200000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4c9980ea-c901-4e92-bb89-6f907b3a5dca", "name": "l(r:p1rdt6505lv-p1rlv13715)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387e7785-8d40-4ddd-8c2b-14a83d4e7401"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a822fdb0-b531-49b0-89da-b517e5ae6e3a"}}}], "length": {"value": 0.00829409, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6c069c68-5c44-4ed0-b1cf-af99663412ef", "name": "l(r:p1rdt6507lv-p1rlv13610)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5844baa-5e0f-4edd-9122-fe4255adad0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17d92377-b4f1-4194-89cd-130bddb9b77c"}}}], "length": {"value": 0.0581195, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "89882ab7-3fbe-4a43-8813-4000db50953d", "name": "l(r:p1rdm14031-p1rlv13712)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a2f5fad-c0a9-4f62-a318-ef00c0d4f470"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ab8bce-7c02-4c7b-962e-3fb44a3ab7a9"}}}], "length": {"value": 0.0677651, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8f8439ca-eff8-40f9-aa8d-d359f0721d26", "name": "l(r:p1rdm14031-p1rdt6507lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5844baa-5e0f-4edd-9122-fe4255adad0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a2f5fad-c0a9-4f62-a318-ef00c0d4f470"}}}], "length": {"value": 0.0164067, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "efd01f17-490e-47c7-8d2e-568a421cec6a", "name": "l(r:p1rdt6508lv-p1rlv13611)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "630b2a63-622f-4f78-8390-77c69ba7e393"}}}], "length": {"value": 0.00515213, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5a1a2657-849d-4e13-8c0c-965a8a7ab30e", "name": "l(r:p1rdt6508lv-p1rlv13666)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5868c24b-2a58-459b-8650-a6072241aca8"}}}], "length": {"value": 0.006682040000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c45a4782-6379-4df5-896d-ba72b47ee680", "name": "l(r:p1rdt6508lv-p1rlv13685)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f777bc74-e6f3-4e80-bb72-0764964db21e"}}}], "length": {"value": 0.04116050000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "485ec2d2-baf3-4031-b775-f3a35c51e1f2", "name": "l(r:p1rdt6508lv-p1rlv13701)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa7a324e-d367-49a5-820a-b18e72243265"}}}], "length": {"value": 0.00980837, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "63ca6e20-b870-4ea1-aaea-7904c242ba8a", "name": "l(r:p1rdt6508lv-p1rlv13707)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "286623b3-af08-4a60-896a-1f5b85fe04a5"}}}], "length": {"value": 0.0432014, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4a2c57de-4589-43cc-8447-5abb34d130a0", "name": "l(r:p1rdm14033-p1rlv13651)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "572123ef-d255-42a9-9c61-95d99aaff775"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c808261e-a49e-4954-bdc4-a8b63d0ee25b"}}}], "length": {"value": 0.0148948, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d9124535-9f55-4e17-90ec-cf5341d9c500", "name": "l(r:p1rdm14033-p1rlv13728)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "572123ef-d255-42a9-9c61-95d99aaff775"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9657a993-0005-4ffc-8c9f-18e80a491070"}}}], "length": {"value": 0.00972322, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cc27c9f6-9b6e-4814-b9c7-7166cc2d1bed", "name": "l(r:p1rdm14033-p1rdt6508lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "572123ef-d255-42a9-9c61-95d99aaff775"}}}], "length": {"value": 0.0189224, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3162f10d-4158-469a-96cd-a51fa01fb20a", "name": "l(r:p1rdt6509lv-p1rlv13612)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f817a28f-c650-4eb4-84c0-751fe5053c75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6eda3e97-a618-41ab-ae55-ba67f6bb0234"}}}], "length": {"value": 0.00552959, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9d01a910-b603-4852-9d53-708297ee103a", "name": "l(r:p1rdt6509lv-p1rlv13628)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f817a28f-c650-4eb4-84c0-751fe5053c75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e47df44a-79f1-423b-a295-c9c354795895"}}}], "length": {"value": 0.0122449, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "516a46a4-a886-40b9-b1ea-e684b208f509", "name": "l(r:p1rdm14041-p1rlv13627)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b65a5fd-f38e-447a-a51a-e7a214ba6bcc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bd69c55-2141-4c8e-becf-efa4bff8a63e"}}}], "length": {"value": 0.0158712, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8cb36820-73d5-492e-8845-b9ec92e8fa18", "name": "l(r:p1rdm14041-p1rlv13659)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b65a5fd-f38e-447a-a51a-e7a214ba6bcc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "122e0772-7de6-4117-b1d3-caafbbbc8e22"}}}], "length": {"value": 0.009054330000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d8df7836-4789-448b-894e-7c1c617c95d9", "name": "l(r:p1rdm14041-p1rlv13660)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b65a5fd-f38e-447a-a51a-e7a214ba6bcc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3d6fd13-2f04-4f23-97a3-cdf99159174c"}}}], "length": {"value": 0.0113115, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "068f969c-0c98-4e0f-9524-1a21a3b8987d", "name": "l(r:p1rdm14041-p1rlv13677)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b65a5fd-f38e-447a-a51a-e7a214ba6bcc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9aa7e62-8974-4ef0-aa5a-bcd545245aea"}}}], "length": {"value": 0.0329272, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "65146649-1d08-42cb-af6c-acc8a012a05e", "name": "l(r:p1rdm14040-p1rlv13624)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1252c522-5ced-4f4c-908c-f58501ad6f92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a5746d1-24a6-4ae4-b5dc-cef23b56660d"}}}], "length": {"value": 0.00954632, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3ae44c1c-f5ef-4516-a648-5583d34cf7a6", "name": "l(r:p1rdm14040-p1rlv13721)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1252c522-5ced-4f4c-908c-f58501ad6f92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6097c903-70fc-4635-a66c-fee2243ba545"}}}], "length": {"value": 0.012462500000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "20173122-d8a7-4c92-a3b7-8ddb76680383", "name": "l(r:p1rdm14040-p1rdm14041)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b65a5fd-f38e-447a-a51a-e7a214ba6bcc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1252c522-5ced-4f4c-908c-f58501ad6f92"}}}], "length": {"value": 0.0125149, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "80fdbbc2-08c7-494f-bc26-6b81701d774b", "name": "l(r:p1rdm14041-p1rdt6509lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f817a28f-c650-4eb4-84c0-751fe5053c75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b65a5fd-f38e-447a-a51a-e7a214ba6bcc"}}}], "length": {"value": 0.0139057, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "52d0c8fb-a66f-4033-93f4-79e9ae946d79"}}}}, {"uuid": "c8f1e6a0-c36c-4ce6-99e7-ee182b295e7f", "name": "l(r:p1rdm14043-p1rlv13633)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9be8942c-8459-4c1d-a3b0-a89ee5cced4e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b3fe33f-fdcf-42f5-be08-8da15a4d4958"}}}], "length": {"value": 0.036068300000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "95e07a95-448b-4b98-80fa-457bcde4ecc4", "name": "l(r:p1rdm14043-p1rlv13663)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9be8942c-8459-4c1d-a3b0-a89ee5cced4e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54887ca7-ae23-42d0-a715-aed8baa38ade"}}}], "length": {"value": 0.0442205, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "17a54982-d8e3-4917-97dd-8e7dbe136d17", "name": "l(r:p1rdm14043-p1rlv13672)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9be8942c-8459-4c1d-a3b0-a89ee5cced4e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32bec8ad-b312-4502-a2a1-6a4c9b2dd87a"}}}], "length": {"value": 0.00371517, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "3e5beb3a-4808-431b-a276-401a1bc26c44", "name": "l(r:p1rdm14043-p1rlv13686)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9be8942c-8459-4c1d-a3b0-a89ee5cced4e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60fe0a16-aa4d-4fe8-9f39-81bfa13b505f"}}}], "length": {"value": 0.0111527, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9accb5a7-67c9-4b12-89a4-03446ebd99ee", "name": "l(r:p1rdm14043-p1rdt6509lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f817a28f-c650-4eb4-84c0-751fe5053c75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9be8942c-8459-4c1d-a3b0-a89ee5cced4e"}}}], "length": {"value": 0.0139057, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ca70462c-125c-4416-a604-f000d21623d6", "name": "l(r:p1rdt6510lv-p1rlv13614)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d62fe3b-7644-46d1-8a15-e86d95ae8b2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3de8b994-01ba-4eae-b9cf-7fb174d32355"}}}], "length": {"value": 0.01924, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bb7235ed-bd23-4bb0-99ce-00d534f6ceba", "name": "l(r:p1rdt6510lv-p1rlv13680)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d62fe3b-7644-46d1-8a15-e86d95ae8b2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85b910cd-def8-41d8-ad47-3c074a54ad8d"}}}], "length": {"value": 0.012694, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "52d0c8fb-a66f-4033-93f4-79e9ae946d79"}}}}, {"uuid": "84cbab40-20ee-4d00-86b9-42817ede7a15", "name": "l(r:p1rdt6510lv-p1rlv20467)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d62fe3b-7644-46d1-8a15-e86d95ae8b2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58e2b774-ac04-435e-9e03-573b3aa94cfb"}}}], "length": {"value": 0.00748899, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ff0d00c0-ac17-4823-ada8-ba030479f1ce", "name": "l(r:p1rdt6512lv-p1rlv13616)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "850d5b69-14cf-4a18-8cb0-4f1b3033b0aa"}}}], "length": {"value": 0.0125419, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2ab15224-388d-4616-8bd6-5a213b6945ec", "name": "l(r:p1rdt6512lv-p1rlv13643)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20009de0-cbe7-4b4f-a046-425a6ae71925"}}}], "length": {"value": 0.0106471, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9af93afe-5223-45fd-a014-1b40d134690d", "name": "l(r:p1rdt6512lv-p1rlv13646)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fe0466e-cce5-4c6c-b13f-cedd349b6944"}}}], "length": {"value": 0.00566202, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "023df541-8d16-46bf-b4d4-675baa72fc8a", "name": "l(r:p1rdt6512lv-p1rlv13650)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fa2041e-34c4-4f1f-a329-74969c3da75f"}}}], "length": {"value": 0.0342408, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "13f8ad6d-758e-44f8-8220-06aef0a4c41b", "name": "l(r:p1rdt6512lv-p1rlv13725)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e290046b-c936-4f51-b4ef-632bf572ab7f"}}}], "length": {"value": 0.0322281, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4947106f-8e2e-4805-b3b7-5e9672aadeac", "name": "l(r:p1rdm14062-p1rlv13664)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3ed4387-9ecb-43c4-a392-e72bc5cb32b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70cf02cc-8f1b-48ab-b9e6-50c3e58ad9ae"}}}], "length": {"value": 0.0332206, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "fe342819-1380-4393-a27d-ccc1439cd615", "name": "l(r:p1rdm14062-p1rlv13681)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3ed4387-9ecb-43c4-a392-e72bc5cb32b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60f08cde-51d3-4b51-9ab5-b61c8043950f"}}}], "length": {"value": 0.00918014, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "96b443e2-11df-4e89-981c-41c80cf02023", "name": "l(r:p1rdm14062-p1rlv13717)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3ed4387-9ecb-43c4-a392-e72bc5cb32b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdbfe616-f51f-416a-94ce-6e676d300226"}}}], "length": {"value": 0.00916206, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "488c4454-9ad4-484f-8d9c-aca4b7f2fd67", "name": "l(r:p1rdm14062-p1rlv20509)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3ed4387-9ecb-43c4-a392-e72bc5cb32b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fe37b51-0258-4812-9d96-3cc28c4bd55b"}}}], "length": {"value": 0.00548688, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "022d323e-07da-4138-8e8b-44b035820841", "name": "l(r:p1rdm14062-p1rdt6512lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3ed4387-9ecb-43c4-a392-e72bc5cb32b6"}}}], "length": {"value": 0.018909400000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e3150130-99fc-424b-93c8-da14b313e743", "name": "l(r:p1rdm14063-p1rlv13671)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "485928ba-ff70-4be2-89ff-721ff82269fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2f95b8b-190c-4df2-9dd2-daee5efde34b"}}}], "length": {"value": 0.0398564, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b6d97809-156e-4113-af17-e0200a96fbff", "name": "l(r:p1rdm14063-p1rlv13714)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "485928ba-ff70-4be2-89ff-721ff82269fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17936036-1191-4f91-bc12-2298db7b77e3"}}}], "length": {"value": 0.0397956, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e0a8749f-fc99-4c40-843a-c950cd6b3617", "name": "l(r:p1rdm14063-p1rdt6512lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "485928ba-ff70-4be2-89ff-721ff82269fb"}}}], "length": {"value": 0.0189224, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "033e3f67-3877-4ae0-b6ec-ed4ac02d0081", "name": "l(r:p1rdt6514lv-p1rlv13623)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad6bef77-8f39-43b4-b2d7-58aa6e45a60b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80f60ab3-722f-4765-8b91-4fd0196171d7"}}}], "length": {"value": 0.0879332, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4c3fb8e9-1d83-4791-8274-8e68fb1645a7", "name": "l(r:p1rdt6514lv-p1rlv13716)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad6bef77-8f39-43b4-b2d7-58aa6e45a60b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb3b4207-12ad-46e6-b4de-59149a46f8a1"}}}], "length": {"value": 0.107138, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b4624fcd-3303-45b7-aeab-e8182705ea7d", "name": "l(r:p1rdm14072-p1rlv13640)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "395dac73-8fae-4718-a28c-191a76a298f2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "653bdc0d-5b21-4640-861b-b88ddb5c651a"}}}], "length": {"value": 0.0819367, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c040ef88-e64c-4303-83fd-b18d037139ca", "name": "l(r:p1rdm14072-p1rdt6514lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad6bef77-8f39-43b4-b2d7-58aa6e45a60b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "395dac73-8fae-4718-a28c-191a76a298f2"}}}], "length": {"value": 0.0139057, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "caa8dcf0-ff72-42e0-b35b-3d850862220e", "name": "l(r:p1rdt6515lv-p1rlv13625)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b92f8bcd-91ce-42bd-be69-0b43cb9d4122"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c667408-52a0-4258-8e93-557c94520a1e"}}}], "length": {"value": 0.09092920000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "61b204a7-5100-4427-bab6-d2a4ff8ae7df", "name": "l(r:p1rdt6515lv-p1rlv19156)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b92f8bcd-91ce-42bd-be69-0b43cb9d4122"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7538ab85-10b4-4f60-98f8-179e954173b0"}}}], "length": {"value": 0.091396, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "c8be5034-7901-4e58-97e7-41c162aba1d0", "name": "l(r:p1rdt6515lv-p1rlv19163)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b92f8bcd-91ce-42bd-be69-0b43cb9d4122"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fed6fcd4-3c97-4f62-a1a7-0b66394218e1"}}}], "length": {"value": 0.0956659, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "6e8f9e3f-5286-4b5c-b948-13135572f5cc", "name": "l(r:p1rdt6515lv-p1rlv19165)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b92f8bcd-91ce-42bd-be69-0b43cb9d4122"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ebd10471-ab4c-4cb7-a822-a83ef20e9854"}}}], "length": {"value": 0.104528, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "188e1e24-abff-4778-add9-5cd6da283c9a", "name": "l(r:p1rdm14075-p1rlv13645)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2659bd3-f6ca-4d74-87c8-f92596986cb5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1acad56e-b6d6-4fa7-a925-f242c1558eef"}}}], "length": {"value": 0.0654705, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "3f25d6c2-6bb8-45d7-aefd-259a75c39fa3", "name": "l(r:p1rdm14075-p1rdt6515lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b92f8bcd-91ce-42bd-be69-0b43cb9d4122"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2659bd3-f6ca-4d74-87c8-f92596986cb5"}}}], "length": {"value": 0.00777706, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "7d73691e-3ace-4804-a2fc-b1e7bb2fc029", "name": "l(r:p1rdt6516lv-p1rlv13629)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "119a8559-8e6c-4314-9bbd-37ef3adde415"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b4358536-b06f-486d-b336-3a8576b428d0"}}}], "length": {"value": 0.0117712, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a9dc2406-fd4a-460a-b563-9f3869e7a46e", "name": "l(r:p1rdt6516lv-p1rlv13638)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "119a8559-8e6c-4314-9bbd-37ef3adde415"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db3908f7-94f5-43a7-a3de-1f6c9b72ebd4"}}}], "length": {"value": 0.009298230000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c42d401a-12f5-41aa-8978-0bab6fef0238", "name": "l(r:p1rdt6516lv-p1rlv13692)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "119a8559-8e6c-4314-9bbd-37ef3adde415"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "091b545a-eb31-4bea-a0a6-5aa9c7a8397f"}}}], "length": {"value": 0.022541900000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9ce6b824-e446-47d8-9b7f-8e6925a36c68", "name": "l(r:p1rdt6516lv-p1rlv13708)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "119a8559-8e6c-4314-9bbd-37ef3adde415"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a230534-6927-4af8-ba54-6ab4c9c32d21"}}}], "length": {"value": 0.020454, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "082fc58b-a217-4336-9a0d-065c229b7951", "name": "l(r:p1rdt6517lv-p1rlv13630)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5783bae9-2c74-473f-bf18-db40bc975409"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f474e4ba-6300-4014-afe9-c245e08cf3c5"}}}], "length": {"value": 0.0228311, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3c1f055c-199b-4923-bf89-d99e150d0252", "name": "l(r:p1rdm14084-p1rlv13641)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "822f96e6-61c5-455d-8a53-a494b49c9237"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eb10938-4b73-406c-bed4-0bd01e0bc20d"}}}], "length": {"value": 0.0127698, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "dfb21f10-33c3-41a3-a751-c1d7711c1c4f", "name": "l(r:p1rdm14084-p1rdt6517lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5783bae9-2c74-473f-bf18-db40bc975409"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "822f96e6-61c5-455d-8a53-a494b49c9237"}}}], "length": {"value": 0.0159549, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b10d847c-d604-4ede-9f26-ef7617eb21ce", "name": "l(r:p1rdt6518lv-p1rlv13647)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b16b03-1922-4aeb-8e70-d0e1387fbcab"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8753d37-07f1-45c6-a483-43cbfb6bf107"}}}], "length": {"value": 0.025624100000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "16c1caa6-a0ac-4132-a871-c1d589aa9772", "name": "l(r:p1rdm14085-p1rlv13632)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c597db56-a6af-472d-a7a2-e331175a2aae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b712121-d0c2-488a-9224-bea72928796f"}}}], "length": {"value": 0.028921, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "37be34c8-1e2b-49f9-8cb3-aa295a059daa", "name": "l(r:p1rdm14085-p1rdt6518lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b16b03-1922-4aeb-8e70-d0e1387fbcab"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c597db56-a6af-472d-a7a2-e331175a2aae"}}}], "length": {"value": 0.0331741, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "344cfb2a-35cd-4e8b-869a-9b28c99943fd", "name": "l(r:p1rdm14087-p1rlv20154)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180c5680-acd1-4988-ac36-1f351c3f9418"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02f2e50e-d42d-47d1-9274-d840042b64d1"}}}], "length": {"value": 0.0527706, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7ae66157-15aa-48f6-87af-00e3416e452b", "name": "l(r:p1rdm14087-p1rlv20161)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180c5680-acd1-4988-ac36-1f351c3f9418"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11a125b8-023c-4748-98a9-d74e9e0a7d23"}}}], "length": {"value": 0.04340720000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2f1e15b7-c811-40be-81ac-e05c3e936d83", "name": "l(r:p1rdm14087-p1rdt6518lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b16b03-1922-4aeb-8e70-d0e1387fbcab"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180c5680-acd1-4988-ac36-1f351c3f9418"}}}], "length": {"value": 0.0198942, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "228f74d1-87c0-4843-809b-e393c84a2239", "name": "l(r:p1rdt6519lv-p1rlv13636)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "606673ea-bcd2-459a-a0af-efb8b31c600c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4d3fe62-b327-4fc6-b2aa-795c9475019a"}}}], "length": {"value": 0.052177, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "167607d2-178f-4e8d-82c4-9bfd9975fab7", "name": "l(r:p1rdm14090-p1rlv13678)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e06b069-62f8-40c8-9abc-d4cc83937e41"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32b75c61-4e97-4e21-a786-8aab7a2d88f8"}}}], "length": {"value": 0.0759194, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "11760911-163e-44ae-af9b-fbbdf0f687b8", "name": "l(r:p1rdm14090-p1rdt6519lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "606673ea-bcd2-459a-a0af-efb8b31c600c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e06b069-62f8-40c8-9abc-d4cc83937e41"}}}], "length": {"value": 0.00898801, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "259929c5-0a19-4150-9cea-ff8dc5a0a7bd", "name": "l(r:p1rdt6520lv-p1rlv13639)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13c02cd3-cff3-4988-95b9-3993b9541427"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5484eab0-53a8-471c-92ec-29c11c08e740"}}}], "length": {"value": 0.0157099, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b03c2024-3c7a-4d2e-8e6e-7d42de59c0a2", "name": "l(r:p1rdt6520lv-p1rlv13669)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13c02cd3-cff3-4988-95b9-3993b9541427"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "607d3b54-2cea-476b-afe2-ea40c6c02ddc"}}}], "length": {"value": 0.00818072, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a2c154da-c79e-4d92-abad-f78947b543a8", "name": "l(r:p1rdm14092-p1rlv13662)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db3abe20-2ffb-4bf8-b425-5613701bd3f2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e55b944-ffad-47bf-8348-799afa4c7a1d"}}}], "length": {"value": 0.0117517, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2509fb4d-0dfc-4537-aac7-0cd0a6a4c808", "name": "l(r:p1rdm14096-p1rlv13679)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0c27b40-83a9-4938-bc12-a2ae57d5eafb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "284bbc5d-bb49-404d-823e-08ec543c90b8"}}}], "length": {"value": 0.0111879, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ad959039-7919-4664-bbfa-b8fc3bb04d8b", "name": "l(r:p1rdm14097-p1rlv13705)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb3a7829-4233-4af9-9679-08bd114bc00e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f409299-5ac0-4f31-a217-d0aef7fbc4d2"}}}], "length": {"value": 0.006644980000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f0c5ad2b-ab0c-47ff-996f-359b98a541c0", "name": "l(r:p1rdm14096-p1rdm14097)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0c27b40-83a9-4938-bc12-a2ae57d5eafb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb3a7829-4233-4af9-9679-08bd114bc00e"}}}], "length": {"value": 0.0158664, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "612c5150-f8fd-4503-afd5-72b168f3a3c8", "name": "l(r:p1rdm14092-p1rdm14096)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db3abe20-2ffb-4bf8-b425-5613701bd3f2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0c27b40-83a9-4938-bc12-a2ae57d5eafb"}}}], "length": {"value": 0.011940100000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "48f450bb-ff89-4556-9044-213f13d84df0", "name": "l(r:p1rdm14092-p1rdt6520lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13c02cd3-cff3-4988-95b9-3993b9541427"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db3abe20-2ffb-4bf8-b425-5613701bd3f2"}}}], "length": {"value": 0.0119317, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "2d347746-0969-4a8a-b986-c40ef4f4c015"}}}}, {"uuid": "83174978-498d-4a0c-9123-99b6f97be3f9", "name": "l(r:p1rdm14094-p1rlv13673)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a990c6c-4227-4896-8ea6-e92ce5360087"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9467d2d3-ad80-4bc7-aa9f-cd6e76494552"}}}], "length": {"value": 0.0209007, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d8400413-4b6f-448c-8b9f-35fd9343fb78", "name": "l(r:p1rdm14094-p1rlv13675)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a990c6c-4227-4896-8ea6-e92ce5360087"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c532e298-bdd5-416e-8ebe-a082489ffee6"}}}], "length": {"value": 0.023550600000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "47cee057-d034-469d-844a-fc4156ee7c4e", "name": "l(r:p1rdm14094-p1rdt6520lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13c02cd3-cff3-4988-95b9-3993b9541427"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a990c6c-4227-4896-8ea6-e92ce5360087"}}}], "length": {"value": 0.0125632, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fa38627e-ef06-43f8-96ec-98da2f37c21e", "name": "l(r:p1rdt6521lv-p1rlv13670)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0e4e42c-8dcd-47be-bfe8-b8b1eb4a5f24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce53d307-fc73-487a-8f6a-3a0e0787bf79"}}}], "length": {"value": 0.106379, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e0336142-b978-433d-8847-480a4107f3f4", "name": "l(r:p1rdt6521lv-p1rlv13694)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0e4e42c-8dcd-47be-bfe8-b8b1eb4a5f24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1de2ebf2-3207-4bf7-9702-4c729d99a6cf"}}}], "length": {"value": 0.07348910000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d686aa67-4e56-444b-b892-d06c1d8df229", "name": "l(r:p1rdt6521lv-p1rlv13695)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0e4e42c-8dcd-47be-bfe8-b8b1eb4a5f24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d73963d7-acf4-48b3-8e54-6ee9f403d36f"}}}], "length": {"value": 0.0966562, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ac3a550d-5246-49d8-ab21-eaaf8dd0a54a", "name": "l(r:p1rdm14098-p1rlv13642)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c12be3d4-719e-4567-91d9-c0ff24b783f1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "479d1486-ed05-44fa-8fab-64035623f267"}}}], "length": {"value": 0.0796353, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a1ad23ef-8d9b-43dd-9d37-af210c9edc45", "name": "l(r:p1rdm14098-p1rdt6521lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0e4e42c-8dcd-47be-bfe8-b8b1eb4a5f24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c12be3d4-719e-4567-91d9-c0ff24b783f1"}}}], "length": {"value": 0.0189224, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0e50b778-8db4-4046-9cbf-af628dd42567", "name": "l(r:p1rdm14100-p1rlv13682)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1db9a47a-f0ed-4141-b08e-f01a2ffd804f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a3c050c-cc0d-460e-af02-ce3421431474"}}}], "length": {"value": 0.0988767, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "26c24a09-ea79-4de4-86a7-17356670bdac", "name": "l(r:p1rdm14100-p1rdt6521lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0e4e42c-8dcd-47be-bfe8-b8b1eb4a5f24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1db9a47a-f0ed-4141-b08e-f01a2ffd804f"}}}], "length": {"value": 0.0189224, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fff836a7-3b7a-4332-8fa2-4ccc5047b40b", "name": "l(r:p1rdt6523lv-p1rlv13649)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66df2481-ae4f-4f39-aef4-7af09ce1a8fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43867e2f-79ee-4cec-bed3-0cad0727118c"}}}], "length": {"value": 0.053244900000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c912605f-1e8e-4af3-bc5a-fbd35d1f82bc", "name": "l(r:p1rdm14107-p1rlv13656)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2844042b-3f65-4a8b-8bab-56b42971e6ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8c0a04e-6e22-4da5-9907-7ae8097deb10"}}}], "length": {"value": 0.0192208, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "76751362-f6a1-47cf-a480-da419e869b1d", "name": "l(r:p1rdm14107-p1rlv13690)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2844042b-3f65-4a8b-8bab-56b42971e6ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "71c26ca3-0d61-46b8-a95b-710e0b760b62"}}}], "length": {"value": 0.0119597, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "8c4f49b2-3881-4901-9e2a-bdfedd44bb67", "name": "l(r:p1rdm14107-p1rdt6524lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ec2137a-f978-4808-a023-21f13464998b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2844042b-3f65-4a8b-8bab-56b42971e6ad"}}}], "length": {"value": 0.00891043, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "3f4222b7-7671-4abc-b6ee-713366959169", "name": "l(r:p1rdm14109-p1rlv13700)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2256f06d-59e9-4822-987f-7d26f40415c0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ecf9ee9-2a3c-431b-84c8-02c7c7aaacb1"}}}], "length": {"value": 0.0052345, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "b11a686c-caa0-43bc-9fc6-0c2a668d3c33", "name": "l(r:p1rdm14109-p1rdt6524lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ec2137a-f978-4808-a023-21f13464998b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2256f06d-59e9-4822-987f-7d26f40415c0"}}}], "length": {"value": 0.00891207, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "dac869e3-d445-4ffc-84be-6aab918f7e32", "name": "l(r:p1rdt6527lv-p1rlv13661)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8905812-7e3b-4875-87b5-da95999c5bb0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ef8e6ec-86d3-429c-89b4-6c7260701e70"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "2b6940c8-d947-4c87-a551-5c24bf4ffeb9", "name": "l(r:p1rdt6528lv-p1rlv13667)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d097d9be-dd3a-4616-a873-8ab5013c4e72"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d6cdd514-204d-4a86-b0f3-a9bc4990a2aa"}}}], "length": {"value": 0.0382292, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "3c9c08f9-58e9-4367-aee8-72788caa6a7c"}}}}, {"uuid": "c6f600b4-98d6-4e13-a8d6-9dc0d58ae55a", "name": "l(r:p1rdt6528lv-p1rlv13691)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d097d9be-dd3a-4616-a873-8ab5013c4e72"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "850df31b-ee95-4903-93b7-6e5911e8f8a0"}}}], "length": {"value": 0.0619169, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "feff346b-96b0-43c5-ae5a-f9eddc172f07", "name": "l(r:p1rdm14115-p1rlv13689)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b51fe8ae-f6d7-48c7-9f84-22fc7c1c1ba9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e5db11f-0418-4119-9c71-26619456fd7b"}}}], "length": {"value": 0.0409354, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "3c183149-1fd7-4707-9de8-d0a10af6da6f", "name": "l(r:p1rdm14115-p1rdt6528lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d097d9be-dd3a-4616-a873-8ab5013c4e72"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b51fe8ae-f6d7-48c7-9f84-22fc7c1c1ba9"}}}], "length": {"value": 0.00777706, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "67b7cc4c-7757-4d4e-8d9f-66ce36da8415", "name": "l(r:p1rdt6530lv-p1rlv13684)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4ee2d3a-e97c-4ec4-9fa0-d7db1b3e9253"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ec49353-14d1-4917-83bc-ca62cd94bf30"}}}], "length": {"value": 0.0531129, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8e8b88c6-aab7-4e5c-b8b9-c3c64a663429", "name": "l(r:p1rdt6531lv-p1rlv13693)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf4a2da0-682a-4119-b398-feaa6f5a8498"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5815b75-1226-4221-9bcb-bc75ce85fa17"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "ebaa7012-6c65-4b0d-908b-50ddad06d587", "name": "l(r:p1rdm14120-p1rlv13706)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75c95c35-ea3f-4958-9512-606f78de92b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e60fc98a-9c1d-4975-a9b9-e37271b4ac81"}}}], "length": {"value": 0.0324151, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "3c9c08f9-58e9-4367-aee8-72788caa6a7c"}}}}, {"uuid": "6d45312d-0cad-43fb-9bad-2ce0e6ad3c31", "name": "l(r:p1rdm14120-p1rdt6532lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0c3e71a-52a1-49b9-a899-c13d639ac0a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75c95c35-ea3f-4958-9512-606f78de92b5"}}}], "length": {"value": 0.00967577, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "3c9c08f9-58e9-4367-aee8-72788caa6a7c"}}}}, {"uuid": "e6ce21d6-2d77-4b8d-867a-87e52bca3ba4", "name": "l(r:p1rdm14121-p1rlv19151)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7194199d-e430-4b76-ae77-4c7f51477eed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e396aca-4116-40a0-8f17-bcd41f709ea5"}}}], "length": {"value": 0.0466133, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "9efd1997-d5b4-4e77-8930-a5f5597896ee", "name": "l(r:p1rdm14121-p1rdt6532lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0c3e71a-52a1-49b9-a899-c13d639ac0a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7194199d-e430-4b76-ae77-4c7f51477eed"}}}], "length": {"value": 0.00812092, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "c7be9070-30f3-4700-8c06-470b65f8f19f", "name": "l(r:p1rdt6535lv-p1rlv13711)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10f0e9fa-75b8-4eaa-a2ad-b6a3fb4ae859"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2bfaa34-267c-4dfd-8b6d-4ab444ac4048"}}}], "length": {"value": 0.0759779, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "f13c5842-49ff-4779-bdb6-34cd8e664711", "name": "l(r:p1rdt6536lv-p1rlv13713)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b93e7299-60a4-49d6-9d34-885860588861"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee766a99-bb6f-4d5c-8513-9d462103f6fc"}}}], "length": {"value": 0.00770954, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "858b6e8d-19a5-47af-b192-7fb99a49e5e2", "name": "l(r:p1rdt6536lv-p1rlv13723)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b93e7299-60a4-49d6-9d34-885860588861"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0f1846b-2515-48ef-9241-0276932f8e75"}}}], "length": {"value": 0.00908442, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "43e3456d-a787-4d4e-bad6-2710f05d6c28", "name": "l(r:p1rdm14127-p1rlv20478)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57ac4a24-2ddb-46c2-873d-c0b4f3e0600a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cd0effe0-d186-41a8-8197-24144fbc6218"}}}], "length": {"value": 0.0197863, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "4e91a915-48a9-4e23-8849-e14ae8fa716d", "name": "l(r:p1rdm14127-p1rdt6536lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b93e7299-60a4-49d6-9d34-885860588861"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57ac4a24-2ddb-46c2-873d-c0b4f3e0600a"}}}], "length": {"value": 0.00732814, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "9e793d61-64cc-44ff-b17b-fa7b43a1ec8f", "name": "l(r:p1rdt6539lv-p1rlv13727)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b34f50ff-9a1f-439e-81a8-dfcee658926b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36019623-eb62-412c-a591-41494980c9b7"}}}], "length": {"value": 0.0347798, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "68c65b63-27dd-4e30-9d5e-0bb769ae8388", "name": "l(r:p1rdt6539lv-p1rlv20450)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b34f50ff-9a1f-439e-81a8-dfcee658926b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "006c2753-37b3-4b59-82a6-8ce95f316e26"}}}], "length": {"value": 0.01495, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8b013ff2-c5d6-4080-83aa-2395a67efb7c", "name": "l(r:p1rdm14185-p1rlv13784)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36ab64e0-65cb-4515-9c06-4762a398672a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01a18948-75cf-4caf-951f-17a9c8d1f6bc"}}}], "length": {"value": 0.029367, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4c5e3312-2084-435a-bade-59ec2dae5db0", "name": "l(r:p1rdm14185-p1rdt6574lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a43920a-a200-40fe-b5b6-3cdba0c7e784"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36ab64e0-65cb-4515-9c06-4762a398672a"}}}], "length": {"value": 0.0286402, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2ecb58ca-d359-49c0-802f-611cc5587743", "name": "l(r:p1rdm14186-p1rlv13812)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f2b4d47-9668-4bcc-933b-1f422f423e3e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ffd737b-a273-4a6c-91c6-351b5719f658"}}}], "length": {"value": 0.011645100000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c1340aaa-b2e7-423c-a24c-4984fc6527d5", "name": "l(r:p1rdm14186-p1rdt6574lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a43920a-a200-40fe-b5b6-3cdba0c7e784"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f2b4d47-9668-4bcc-933b-1f422f423e3e"}}}], "length": {"value": 0.0169575, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "88709a42-68a3-404c-a28c-0c84626b3f70", "name": "l(r:p1rdt6581lv-p1rlv13797)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "608e485b-13ce-493b-be96-ab83ad733c92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65052833-aec9-4363-a0cf-4d70fa9bb0ce"}}}], "length": {"value": 0.0873919, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7a451c89-27b1-4961-b1d0-940b9033cd52", "name": "l(r:p1rdt6581lv-p1rlv13811)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "608e485b-13ce-493b-be96-ab83ad733c92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aef2ef8-706c-4316-be01-0707ddf0ac7c"}}}], "length": {"value": 0.06100800000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "93cc41fd-d6c5-4fe6-ae2e-4ba53376e452", "name": "l(r:p1rdm14205-p1rlv13792)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8b7c677-d0bf-47d0-8a2a-78417faa49b9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc5fcb56-435a-4a0d-b442-7489a98ad1cd"}}}], "length": {"value": 0.0873214, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ba97f8d3-dd14-4104-a0f9-e265a224b585", "name": "l(r:p1rdm14205-p1rlv13794)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8b7c677-d0bf-47d0-8a2a-78417faa49b9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9725b6c-5bac-456a-bb6a-ce16a5e6b1a5"}}}], "length": {"value": 0.0656609, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ac827c47-9381-4673-914b-eb251a3782c1", "name": "l(r:p1rdm14205-p1rlv13805)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8b7c677-d0bf-47d0-8a2a-78417faa49b9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83d60921-a1f2-4b9c-9709-d2be59b82db5"}}}], "length": {"value": 0.10165500000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "374da000-183c-490f-b8e4-90a747756774", "name": "l(r:p1rdm14205-p1rdt6581lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "608e485b-13ce-493b-be96-ab83ad733c92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8b7c677-d0bf-47d0-8a2a-78417faa49b9"}}}], "length": {"value": 0.0195453, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9b2db3aa-d79e-4506-8730-e7ec07f13f78", "name": "l(r:p1rdm14210-p1rlv19691)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "487eef02-df2d-47fe-a20b-ce1c23064495"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "604cb559-0f18-4ef7-8bcd-a07a7e7f96d7"}}}], "length": {"value": 0.0580592, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9845e9a8-a0e8-4ac8-b23f-43c8a5ec35c0", "name": "l(r:p1rdm14210-p1rdt6581lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "608e485b-13ce-493b-be96-ab83ad733c92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "487eef02-df2d-47fe-a20b-ce1c23064495"}}}], "length": {"value": 0.0390906, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c0b95dfe-dbb0-4b9d-aea3-888bbaae0e4d", "name": "l(r:p1rdt6847lv-p1rlv14434)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7b9897e-b820-424c-adf8-7416de585357"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06135bd7-6a77-4f04-a439-4ce8c245447d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "17c6ca6d-e99b-4b1e-b84a-cfdad5216da5", "name": "l(r:p1rdt6848lv-p1rlv14435)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94c9fa37-fc5c-4243-b0ca-f70840febaee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d07f5065-df41-484d-8e8a-80b2ff4e0e9b"}}}], "length": {"value": 0.012328000000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ed6ec446-d1e2-423b-95f6-3a2124d16714", "name": "l(r:p1rdt6848lv-p1rlv14436)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94c9fa37-fc5c-4243-b0ca-f70840febaee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad66e41a-88ab-443e-b10e-9e7b5b899119"}}}], "length": {"value": 0.012328000000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fab1734a-805a-45b3-bb29-8ec6cc98ff61", "name": "l(r:p1rdt6995lv-p1rlv14828)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09a476ff-48a0-4d27-9cf0-c007e2e98acb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9efa4c9-9832-4aa8-bf44-be0fe1e80cd5"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b55a7233-970e-4b46-bded-059f90e68dc0", "name": "l(r:p1rdt7015lv-p1rlv14908)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "536d7c56-85a6-4167-b4f6-2f39936cd662"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d73b0321-e181-4ecd-b431-9aa6985d56d0"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "72e2c700-4f3a-43a7-acef-5408f66d50aa", "name": "l(r:p1rdt7036lv-p1rlv14952)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a371c8b-1993-432c-b2c6-21b18bec27da"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3c39b0c-9c92-4934-876f-ee5f542f95cc"}}}], "length": {"value": 0.0147598, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d89a8c28-6964-4a2f-886e-cc984f5a7748", "name": "l(r:p1rdm15468-p1rlv15008)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "260ea1f0-7235-47fc-a576-3d647618290e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19231152-1fd1-4e07-a5d9-603c765b2cae"}}}], "length": {"value": 0.028564100000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b8d33ec2-8be0-4cba-8ff9-a32946eebaf4", "name": "l(r:p1rdm15468-p1rdt7036lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a371c8b-1993-432c-b2c6-21b18bec27da"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "260ea1f0-7235-47fc-a576-3d647618290e"}}}], "length": {"value": 0.0178658, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "97dfa04d-243a-4a4e-83a9-a041fdabcedc", "name": "l(r:p1rdt7038lv-p1rlv14954)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "046f6c53-8d9c-43a1-88ce-169ade9e9557"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9e128f5-eb18-44df-8ec4-35bd049ef630"}}}], "length": {"value": 0.00867639, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e3736839-7824-4b4e-aa1d-9cfd6a158fad", "name": "l(r:p1rdt7046lv-p1rlv14974)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cd6a9808-9889-4f16-825d-c9763357c293"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "884ff47e-8e20-4ae8-97bd-287d0ca9dc1b"}}}], "length": {"value": 0.010648, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "47d4754c-c9fb-4def-99b6-c75a6071c19d", "name": "l(r:p1rdt7054lv-p1rlv14992)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf93e681-3ab6-4929-95f1-1da6d5dd28fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4f8b1bc-83c3-4819-9d98-9491df98d494"}}}], "length": {"value": 0.0136862, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "212f4598-9e6d-4b92-a3d1-44610b4910f8", "name": "l(r:p1rdt7054lv-p1rlv15056)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf93e681-3ab6-4929-95f1-1da6d5dd28fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a914ec3a-4883-42a7-b25d-133a1410b8d9"}}}], "length": {"value": 0.0326989, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e190be67-e711-4051-bfd1-1e315ff72cb0", "name": "l(r:p1rdm15533-p1rlv15046)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25a6c92d-ea7f-4ede-af16-713ceedfc7b0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2182c9fd-fd3d-4cb1-b525-192480823e2f"}}}], "length": {"value": 0.0227649, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "37ac8bba-efa1-4bbc-bda6-22e4836756ce", "name": "l(r:p1rdm15533-p1rdt7054lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf93e681-3ab6-4929-95f1-1da6d5dd28fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25a6c92d-ea7f-4ede-af16-713ceedfc7b0"}}}], "length": {"value": 0.0107297, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2a79d577-2b03-4ef6-84e6-afb335adaea1", "name": "l(r:p1rdt7061lv-p1rlv15007)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc33ade7-4471-40b8-8e9b-1846e0ad60e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc29de5b-3a3f-40c0-bde4-9a57f5f62b5c"}}}], "length": {"value": 0.0316282, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "353ebd25-352a-4d04-9ead-4c6d9ddf80fc", "name": "l(r:p1rdm15583-p1rlv15027)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4445ca5-2fed-4352-ab78-66e072a4f482"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07e3b847-cc9a-4f84-bc00-cb4396b6dea0"}}}], "length": {"value": 0.0140589, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2559653c-404f-472f-89ab-b0aa2c33fe36", "name": "l(r:p1rdm15583-p1rdt7067lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ff878e1-3143-4f8e-aa92-74d0a9046417"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4445ca5-2fed-4352-ab78-66e072a4f482"}}}], "length": {"value": 0.06079190000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "257d6011-c8ae-4eed-b4c4-a349d68240c2", "name": "l(r:p1rdm15584-p1rlv15197)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ad4c131-0be7-46e5-8a32-5ff92552dfe6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80a74c6f-c9ec-4742-8fce-ad73c0a6c459"}}}], "length": {"value": 0.0228694, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d7e0b635-9e9d-4d19-b7fe-d028520488c2", "name": "l(r:p1rdm15584-p1rdt7067lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ff878e1-3143-4f8e-aa92-74d0a9046417"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ad4c131-0be7-46e5-8a32-5ff92552dfe6"}}}], "length": {"value": 0.0279022, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b6c37323-999f-4652-8438-a4e92ddec55f", "name": "l(r:p1rdt7069lv-p1rlv15045)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a1566f1-7f0d-41d7-adad-425c9a344eb0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "baccbdab-efc0-487d-b00d-38d3d4be57b4"}}}], "length": {"value": 0.08356350000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f4a62cdd-7ebe-4533-9ebe-30b2bc677c77", "name": "l(r:p1rdt7070lv-p1rlv15064)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "844bdc22-2e32-43ee-8e0b-26f3f4c107b8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "366c9c98-59f1-46d5-b39c-4046703e5e4b"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "a5acdfb1-a2f0-43f1-87c9-737ff5f1e24f", "name": "l(r:p1rdt7075lv-p1rlv15082)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e0577c2-8275-4303-ad11-2c4f56df3f5c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a56b9ad8-c53b-4652-bf94-a7a7dfb8b306"}}}], "length": {"value": 0.00723071, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "72eeb4f8-eec2-4e80-be4c-3ff5014734e2", "name": "l(r:p1rdt7080lv-p1rlv15109)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d86bd7f-7759-4d74-9c74-d58010498f92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "161d4e7b-30f2-447c-a369-1bfa3ba2cd70"}}}], "length": {"value": 0.0109809, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6dce47af-355e-492c-8ada-a69635288723", "name": "l(r:p1rdt7080lv-p1rlv15125)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d86bd7f-7759-4d74-9c74-d58010498f92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb6d8f13-f04e-4b80-a8dc-e16af1dc860e"}}}], "length": {"value": 0.0299076, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8cdd54a6-9f8d-4ee6-87ab-ae1b4d397431", "name": "l(r:p1rdt7087lv-p1rlv15163)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d0c96fe-78c2-4303-ac5c-bbe440f19666"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdee6d84-9253-4fba-b713-3e41d706e999"}}}], "length": {"value": 0.0407888, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "44e14507-623a-45b0-be7a-6186032730df", "name": "l(r:p1rdt7088lv-p1rlv15170)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f1652e8-6cf7-43d4-8474-e61a74873675"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d2f8fcb-c279-49d5-88be-39e6a1d1990b"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "d401fdd0-f323-47cf-9b6e-243c4816d543", "name": "l(r:p1rdt7089lv-p1rlv15171)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73cfcce9-a925-4f29-9cde-6dd6f50735e1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc7cd505-823c-49bb-9e49-3681267dbef0"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "6e104f67-822c-4dfe-821e-3d2270eaf935", "name": "l(r:p1rdt7090lv-p1rlv15180)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d6a4c80-d261-4350-8224-8fe5191459c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e218b01d-f713-4baf-9688-7e77ea413c8c"}}}], "length": {"value": 0.0031637000000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b937d1b0-3310-4bcf-9eec-ea96efd2c7d7", "name": "l(r:p1rdt7201lv-p1rlv15394)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6718b871-3967-4c29-83e5-441799c7fb92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd21ae8b-7841-43b4-871f-316c4b8b4cd2"}}}], "length": {"value": 0.0100846, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5875340a-352d-4b74-98dc-8883439cd675", "name": "l(r:p1rdt7201lv-p1rlv15399)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6718b871-3967-4c29-83e5-441799c7fb92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ec1f313-f341-498c-b1c2-6669b1cbc629"}}}], "length": {"value": 0.042765000000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "af21b504-5bae-4a97-84c8-ae9d4024e5de", "name": "l(r:p1rdt7201lv-p1rlv15419)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6718b871-3967-4c29-83e5-441799c7fb92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8bc46399-0276-4ae7-aa8b-4cdd3d3555e8"}}}], "length": {"value": 0.018884, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7be73f4f-717a-4cc3-883f-c8f78b45e694", "name": "l(r:p1rdt7201lv-p1rlv15478)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6718b871-3967-4c29-83e5-441799c7fb92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "335df4da-50d2-4fbe-a271-ac04257d35c7"}}}], "length": {"value": 0.031123500000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c680c5e9-2427-48d6-b643-b718a5387491", "name": "l(r:p1rdt7201lv-p1rlv15523)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6718b871-3967-4c29-83e5-441799c7fb92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37ccfa64-1373-49b2-85f6-279abea3c945"}}}], "length": {"value": 0.0693229, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ff3b35e7-9cbd-4064-b36f-4258d2d5cc0d", "name": "l(r:p1rdt7220lv-p1rlv15418)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d5e45d6-867a-4442-8258-2c04891dbc4b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9ca373a-b1c3-464d-bbe3-c05b728beb30"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "53336b97-0132-489e-86d2-5eec0f08b652", "name": "l(r:p1rdt7224lv-p1rlv15487)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d6a6156f-e72a-41f0-a307-e6030de24fde"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "921f8f54-ff83-4d2f-8bf4-ee80bab64ce8"}}}], "length": {"value": 0.0279743, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "907ce719-e56e-447c-b64f-d358a020f2fe", "name": "l(r:p1rdm15891-p1rlv15423)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79c5341b-3cd2-41a3-8bbf-e50857b00dae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26009a7e-9bfc-4967-af28-4d8937539eb1"}}}], "length": {"value": 0.027741000000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "393d7862-5b0a-4473-8ea7-c88cb9850068", "name": "l(r:p1rdm15891-p1rlv15474)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79c5341b-3cd2-41a3-8bbf-e50857b00dae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34e0ffc2-da17-441b-bd4d-26d5a1104712"}}}], "length": {"value": 0.0128476, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c8ea9ba6-341b-45bd-b369-354bb85e916f", "name": "l(r:p1rdm15891-p1rdt7224lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d6a6156f-e72a-41f0-a307-e6030de24fde"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79c5341b-3cd2-41a3-8bbf-e50857b00dae"}}}], "length": {"value": 0.0173084, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c4bc4441-c550-4b03-b0a0-efd60aadab66", "name": "l(r:p1rdt7248lv-p1rlv15466)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2087cee5-9f6e-4400-8ca8-bbb120cd4dae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "544be417-0db6-45a7-8314-ec40944781fa"}}}], "length": {"value": 0.00486903, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "15f7249a-14e6-4e3e-b936-42cf2e976a8b", "name": "l(r:p1rdt7248lv-p1rlv15483)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2087cee5-9f6e-4400-8ca8-bbb120cd4dae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c4e3eac-0b1a-4feb-b39f-079c6d2c1d82"}}}], "length": {"value": 0.0134294, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "04240cde-fe5e-4ae9-98d1-50fa051dd3c0", "name": "l(r:p1rdt7248lv-p1rlv15488)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2087cee5-9f6e-4400-8ca8-bbb120cd4dae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6579cc93-2b08-4010-816d-3bef509000cd"}}}], "length": {"value": 0.0434873, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2566c35a-0bf0-403c-be22-cd9edfb06e03", "name": "l(r:p1rdt7248lv-p1rlv15542)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2087cee5-9f6e-4400-8ca8-bbb120cd4dae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b09822b3-a220-48ff-ad4f-62fca602f8b6"}}}], "length": {"value": 0.0301654, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ee4e3654-f1a1-4d89-8f99-33119ceee479", "name": "l(r:p1rdt7253lv-p1rlv15484)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b4f7df4-5453-459d-8599-48fd5f29a9c6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6749066f-4739-41ec-8369-8da49dd9e1c8"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "42542b12-3e8e-4532-8026-92a216e7df40", "name": "l(r:p1rdt7268lv-p1rlv15525)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1130272e-b98e-496f-aeb9-c094cf9cd824"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6eec860d-08cf-4690-93e6-d909429d363d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "34b56bb4-acd5-442f-98dd-ae6a6000c99a", "name": "l(r:p1rdt7298lv-p1rlv15603)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d304e5e0-2cc1-4167-9fad-6fc72228d828"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "688da57a-6f10-4ef8-8763-202a88c3a495"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b91e6094-8b96-4b15-affe-53e4ab5b4c33", "name": "l(r:p1rdt7301lv-p1rlv15606)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43df4c14-a198-4d51-87f4-80000198cd47"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c32ce070-e690-4fc1-92ac-f857691de578"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "03539cf6-cfd1-4610-938a-815b5e0a0d89", "name": "l(r:p1rdt7302lv-p1rlv15607)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e2a141f-436a-45c0-9c15-179301a439c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32291502-d7be-4b45-8af7-cb217448e73f"}}}], "length": {"value": 0.0250222, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5e2c78d8-d1ca-458b-b93a-19d040944540", "name": "l(r:p1rdt7302lv-p1rlv15638)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e2a141f-436a-45c0-9c15-179301a439c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2715a637-d6f0-4e7b-b43e-20836bf4e614"}}}], "length": {"value": 0.0170411, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "114bfef7-5a42-4ad7-9635-b2c6241c80ff", "name": "l(r:p1rdt7306lv-p1rlv15614)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0926064a-1c87-450a-b282-23708de8aec4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ab2d6dc-f5bb-4320-86f3-bf08bb7cf93f"}}}], "length": {"value": 0.0921771, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "78f8538c-a644-4746-acd7-376a89bed97f", "name": "l(r:p1rdt7307lv-p1rlv15617)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ce9dd2c-9e17-46b7-a6f4-e85077664432"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6106bbe7-7a47-4c50-8b2a-d46d7432bccf"}}}], "length": {"value": 0.0103904, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "001dcfc9-4762-41f3-a424-9dcf9b505aca", "name": "l(r:p1rdt7307lv-p1rlv19146)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ce9dd2c-9e17-46b7-a6f4-e85077664432"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0bb184ad-cb26-4317-8c40-f2c8a9f80dab"}}}], "length": {"value": 0.0154412, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "653186ed-25f7-4a39-a24e-19bebabe5ff2", "name": "l(r:p1rdt7307lv-p1rlv19147)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ce9dd2c-9e17-46b7-a6f4-e85077664432"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "546433b3-d70e-49ed-9037-ec88adda79b9"}}}], "length": {"value": 0.0170949, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9cd99dc2-42f9-42a3-a539-3e46d435271c", "name": "l(r:p1rdt7311lv-p1rlv15622)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2d6046b-9ece-4295-a180-41bf2ce47ce6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1151b559-3ae0-4863-9363-9b395bbfc403"}}}], "length": {"value": 0.0755258, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "851d4bfa-61f2-4b83-92e2-03d2d1598df4", "name": "l(r:p1rdt7314lv-p1rlv15629)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97844fdb-b016-4ca3-8777-b0553ead9297"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec0bca53-a58b-4004-8dba-8defca9db4c7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "22a94b20-8087-46c1-8f36-29081323b267", "name": "l(r:p1rdt7318lv-p1rlv15634)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22b1ecce-d5df-4f42-abb2-9f4c3d3a28c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5af6dae-d20f-4a31-9544-b9455cd639bd"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "2c8762b9-a727-48e6-8626-8b0691e21672", "name": "l(r:p1rdt7550lv-p1rlv16114)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58be5cbe-5a7c-4fa5-972d-e03100b3bb46"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5984e209-9f0e-4844-91e6-902c8329f13c"}}}], "length": {"value": 0.010568, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "eb9dc53f-9107-4f64-8499-6dcf08b592a2", "name": "l(r:p1rdt7550lv-p1rlv16178)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58be5cbe-5a7c-4fa5-972d-e03100b3bb46"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "807b0bef-0d34-44a9-a2a9-0c0a11f4ea8e"}}}], "length": {"value": 0.010568, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7c32c8d6-dd37-4fda-9b4f-cefafc028e7d", "name": "l(r:p1rdt7551lv-p1rlv16115)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c4d7ee3-fc5d-4a17-a717-3d6b6d5a67ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52d1b79d-5c6b-4b44-9998-600c6debd999"}}}], "length": {"value": 0.0259188, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3b54588d-c6e8-4042-a694-8f87967ab8fa", "name": "l(r:p1rdt7551lv-p1rlv16157)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c4d7ee3-fc5d-4a17-a717-3d6b6d5a67ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6efff4f7-c67b-4cfb-a72d-30b6616825b1"}}}], "length": {"value": 0.0259188, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b929915f-3f5c-4a02-a605-4d4873b39119", "name": "l(r:p1rdt7552lv-p1rlv16116)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f5d6708-cef4-4aac-9fa0-c738953c788f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "972f8088-b67b-47d0-a86f-49179dfb1c92"}}}], "length": {"value": 0.0159262, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c71cbb71-235a-44d4-b728-c68916a4acd2", "name": "l(r:p1rdt7552lv-p1rlv16197)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f5d6708-cef4-4aac-9fa0-c738953c788f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "92a37082-36d4-4eca-95e4-88dbcacd6db5"}}}], "length": {"value": 0.0159262, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ec088b7a-ade2-41ea-864c-57e6fd14b91d", "name": "l(r:p1rdt7553lv-p1rlv16117)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7a672b2-d127-4fb5-8cc4-8115b8ef3f60"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "204899ec-81e4-4a72-bf70-69b3428a49a1"}}}], "length": {"value": 0.0305725, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a08734c0-f8c0-4514-bd5a-0a14ae6698f8", "name": "l(r:p1rdt7554lv-p1rlv16118)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86a6d184-d883-4e27-aee5-b89c82163284"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bca0b3a0-d4cb-4a4a-9b14-aa23d9e5e5fe"}}}], "length": {"value": 0.0431821, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "104b928d-0e37-4538-86e0-e3ce3f7cc27b", "name": "l(r:p1rdt7554lv-p1rlv16139)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86a6d184-d883-4e27-aee5-b89c82163284"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c840cf3f-be15-448b-8c03-8942c586b135"}}}], "length": {"value": 0.0529135, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "abbad3a6-93e2-42c7-a931-18251d488605", "name": "l(r:p1rdt7554lv-p1rlv16201)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86a6d184-d883-4e27-aee5-b89c82163284"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68aa5cc5-f6bf-4417-8653-747c56b37b5e"}}}], "length": {"value": 0.0637427, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f7fbf2cc-e76a-457d-ae93-ed19e5ec96f4", "name": "l(r:p1rdt7554lv-p1rlv16209)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86a6d184-d883-4e27-aee5-b89c82163284"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf413742-18c8-483d-b8f1-f125f95323da"}}}], "length": {"value": 0.0332888, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "da4e7bb9-ac02-48a7-8773-f803a9aa7a98", "name": "l(r:p1rdt7555lv-p1rlv16119)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0de9c581-b78b-44d6-8693-59b995e2a3bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0d6e608-d5bf-40d6-9efd-f3b0922e7d77"}}}], "length": {"value": 0.0197555, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "55ec2ab9-796c-472c-8a9d-64fbe049e120", "name": "l(r:p1rdt7559lv-p1rlv16124)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b593ec6-e1e3-48c2-b352-f7966f206aa9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6da4b2d0-66c7-43fb-9aab-3bbac03aa989"}}}], "length": {"value": 0.04179700000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a4d01ff6-e324-423e-8097-8fe2dde83c0c", "name": "l(r:p1rdt7561lv-p1rlv16126)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05e30abd-3c40-4dbd-9261-ca8a8abd9c56"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd41f55a-4b5d-4c19-9787-801072b3b946"}}}], "length": {"value": 0.014319000000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "54c5bc8b-b799-4216-ab3d-e01ebf98fd85", "name": "l(r:p1rdt7561lv-p1rlv16133)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05e30abd-3c40-4dbd-9261-ca8a8abd9c56"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "102b9460-ea9a-4099-b16f-40b8fdf99ef7"}}}], "length": {"value": 0.024141, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "08cb3840-ba64-4648-ac83-a9a0a208e7ba", "name": "l(r:p1rdt7564lv-p1rlv16135)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7588b3b-f54c-483d-b354-b9908483019a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "676de1a3-2dfd-4faa-a057-7739e825d136"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "eb5f1aa9-9ff8-40fd-8116-08d5bd2f5b05", "name": "l(r:p1rdt7570lv-p1rlv16146)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2b3b9e1-3d98-44c1-bd38-9325623a1553"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6d21c357-1033-45e1-84a0-b82ceafe6ab8"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "7d8cd8ac-49ed-4d0d-80aa-a56a0a98e204", "name": "l(r:p1rdt7572lv-p1rlv16149)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69bf048e-54cd-4e41-a23e-485b0cd98fae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b15792ca-a6bd-47e5-8c67-5c3076174848"}}}], "length": {"value": 0.0827433, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f9ca3f6b-08b6-438b-9f86-993d7fa5dd9e", "name": "l(r:p1rdt7572lv-p1rlv16200)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69bf048e-54cd-4e41-a23e-485b0cd98fae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1aacea55-115d-46c3-9590-725cf5040f38"}}}], "length": {"value": 0.0976866, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a44b7dcd-89ab-4bca-aa5d-4fbe0e9b4b31", "name": "l(r:p1rdm16630-p1rlv16158)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33a848c7-076e-4025-863b-ce9151bcc3ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b85e180a-8eb4-4acc-a816-d99758cc16ea"}}}], "length": {"value": 0.0621197, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c4c0ee7e-a839-4490-b368-ac306b9905e2", "name": "l(r:p1rdm16630-p1rdt7572lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69bf048e-54cd-4e41-a23e-485b0cd98fae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33a848c7-076e-4025-863b-ce9151bcc3ac"}}}], "length": {"value": 0.0168609, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ffb75304-be2a-4021-9df7-22035d0c632a", "name": "l(r:p1rdt7574lv-p1rlv16156)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a742708-0f8b-42d0-a977-b5ce5e36a042"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "74edd9e9-24a5-4b36-8ca8-24ef2fa3e972"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "c9189682-4127-4793-8dde-134bd7a7291f", "name": "l(r:p1rdt7576lv-p1rlv16168)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56b05024-7907-458d-a5c3-0e54ffbabdb5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fb5abb7-dd79-49aa-9185-88a90bb45bc7"}}}], "length": {"value": 0.0685246, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4d947146-90b2-45ec-bc1d-69b52e20c50d", "name": "l(r:p1rdt7579lv-p1rlv16177)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d00b7fe-0384-4c12-a0cf-8895458d3b80"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbbe8401-53a1-4ce7-9ce1-02f547055d95"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "e1f41f9d-38bc-4e6e-be1e-8944e4b9739e", "name": "l(r:p1rdt7588lv-p1rlv16206)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abc940b0-c9f5-4582-adaf-ad7f4a79a35f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ca42395-8d67-4e83-80ec-159cacb490f8"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "607adf52-d8db-4ffb-af17-e06b4b4fbc79", "name": "l(r:p1rdt7589lv-p1rlv16210)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53e9cf92-1c91-428f-bdff-64257257ad5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fd05f3c-df77-45bc-8686-458b681a3d08"}}}], "length": {"value": 0.0134298, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a5726d13-5f87-414f-b712-c0bdc1ced439", "name": "l(r:p1rdt7589lv-p1rlv16235)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53e9cf92-1c91-428f-bdff-64257257ad5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56b91b3f-dfdd-41bf-9d2e-a8183077c752"}}}], "length": {"value": 0.0134298, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "83719399-628f-43ed-9d51-afa6375509c4", "name": "l(r:p1rdt7598lv-p1rlv16221)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff1e0d26-d845-43c3-9aaf-01d1c007b9a1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9761003-33fa-482a-967b-b508ab67c19f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "28e30c05-116b-48f0-b762-f119ac7be7c2", "name": "l(r:p1rdt7599lv-p1rlv16222)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d838502-3769-4d70-839b-26fd628ce478"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4809afc1-2d3d-491d-80e5-9cd4e8da08f2"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "5b38ef2e-a672-495a-8c15-b228d75558b7", "name": "l(r:p1rdt7605lv-p1rlv16228)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3488ff0-696f-4180-bc70-41ff37f9c365"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8767650-39c5-4d4a-80ce-af408c246599"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "ec9d0c28-58f8-4219-86b8-4d3fe6dc4315", "name": "l(r:p1rdt7612lv-p1rlv16239)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fdfea70-187a-4bbc-ba3f-69cb74c4d5c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9642fa30-e5f7-42f1-8fda-ab75a265d25a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "ea4ba13f-ec5f-47ae-a475-1ff409bfad77", "name": "l(r:p1rdt7615lv-p1rlv16242)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "269e9ba5-bc54-4cbd-9140-4b1bea74fc53"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e82036d9-e6c8-42c3-b45b-30bef6902bbc"}}}], "length": {"value": 0.0438853, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "66f3614c-b762-431c-bba3-5445c8ac5bc5", "name": "l(r:p1rdt7615lv-p1rlv16261)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "269e9ba5-bc54-4cbd-9140-4b1bea74fc53"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "978533ca-ef57-4cb6-9e7f-b3c6d1bbd7d5"}}}], "length": {"value": 0.0039062, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "65534143-6fae-4784-bacd-558a8b721a34", "name": "l(r:p1rdm16694-p1rlv16253)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65458dd3-50e0-48d3-a0db-0015707d3cea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "268549c6-0c8b-44ac-b933-316b36645366"}}}], "length": {"value": 0.00713936, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "33912f3d-e42a-475f-8eb4-4cf6ed16c0e4", "name": "l(r:p1rdm16694-p1rdt7616lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6af13868-ecb1-4110-be3f-537741287035"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65458dd3-50e0-48d3-a0db-0015707d3cea"}}}], "length": {"value": 0.04559330000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1e096ee0-46cf-48e0-a5c7-6ea777f3864e", "name": "l(r:p1rdm16695-p1rlv16270)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83d31d7a-8900-4f2e-9183-8a10f07e2bdd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c620d4b9-a849-4bf6-b108-118836866602"}}}], "length": {"value": 0.00252406, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "fe55db9e-e385-467e-b205-95aee0e835b4", "name": "l(r:p1rdm16693-p1rlv16243)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "766647d4-7c3c-4058-b30c-dbc593b88ecb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20818cc7-617e-4ab7-8f7c-31eea6496a02"}}}], "length": {"value": 0.00264008, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "80ef82e9-89e1-4cdc-96a2-6fa1ad7525c5", "name": "l(r:p1rdm16693-p1rdm16695)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83d31d7a-8900-4f2e-9183-8a10f07e2bdd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "766647d4-7c3c-4058-b30c-dbc593b88ecb"}}}], "length": {"value": 0.0423278, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "cfe5162e-a033-4a41-818f-eae382c104ad", "name": "l(r:p1rdm16695-p1rdt7616lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6af13868-ecb1-4110-be3f-537741287035"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83d31d7a-8900-4f2e-9183-8a10f07e2bdd"}}}], "length": {"value": 0.0158248, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "2d347746-0969-4a8a-b986-c40ef4f4c015"}}}}, {"uuid": "81f9870b-57d8-46dd-8268-9ddfab130818", "name": "l(r:p1rdt7617lv-p1rlv16244)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4be4af94-fee7-40d6-9061-9a0fe0e7377e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0164339-acc1-4b95-aa31-3af42cf943f7"}}}], "length": {"value": 0.0112872, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "713a3da4-b5d5-4fbf-98a9-8452a1617c74", "name": "l(r:p1rdm16697-p1rlv16255)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d1fb8eb-57aa-4366-afe5-b79174f3a4c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04647fad-19dc-4ed8-8820-aa312674145c"}}}], "length": {"value": 0.0169738, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c2ff74fe-7d8e-4aeb-8e9c-f1f0a2cb7fde", "name": "l(r:p1rdm16697-p1rdt7617lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4be4af94-fee7-40d6-9061-9a0fe0e7377e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d1fb8eb-57aa-4366-afe5-b79174f3a4c7"}}}], "length": {"value": 0.0068104, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bac616b7-1504-4880-87c4-0dbc21ee3814", "name": "l(r:p1rdm16699-p1rlv16252)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "795f4296-7c54-4e96-8468-52903af39708"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5c6a5f39-0654-4e73-8050-c6c4ad9d54e6"}}}], "length": {"value": 0.0353234, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e02a1459-a30a-43eb-9142-957ff82ef685", "name": "l(r:p1rdm16698-p1rlv16245)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acb015a8-a9f8-492b-ab3f-b107bd956f91"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3783c838-b72e-42cd-8b0b-3005bca3cf5e"}}}], "length": {"value": 0.0114502, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "47db165b-0d9a-4146-8789-b79d73c2dd6c", "name": "l(r:p1rdm16698-p1rdm16699)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "795f4296-7c54-4e96-8468-52903af39708"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acb015a8-a9f8-492b-ab3f-b107bd956f91"}}}], "length": {"value": 0.0170042, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ea0f86b2-7d46-447e-afb9-c85eb9d4acac", "name": "l(r:p1rdm16699-p1rdt7618lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49f37435-54fc-42b4-baba-94f0611c8c76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "795f4296-7c54-4e96-8468-52903af39708"}}}], "length": {"value": 0.0170124, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f5a0982c-76ee-4c76-b17b-db2b29132c0a", "name": "l(r:p1rdm16700-p1rlv16267)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73030a97-0574-4802-80d1-14fefeafa63a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19aeb510-ac0e-4279-8db0-8de282beccc8"}}}], "length": {"value": 0.0129138, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ab960f3a-b750-4490-8919-1b78f1ee81f9", "name": "l(r:p1rdm16700-p1rdt7618lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49f37435-54fc-42b4-baba-94f0611c8c76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73030a97-0574-4802-80d1-14fefeafa63a"}}}], "length": {"value": 0.0510234, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "aef758c3-6056-49d2-8a02-60b50c63bd6e", "name": "l(r:p1rdt7619lv-p1rlv16246)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a205379-48f9-444c-baf8-dc84fc9c6d8a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd2dc2db-787a-4732-bae4-01186082a92d"}}}], "length": {"value": 0.0487659, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1ba0dfcc-9d4f-4d9d-9b25-d4ac783d610a", "name": "l(r:p1rdt7620lv-p1rlv16247)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af91c50-929d-4ac6-9272-7c44d17a0094"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8d5e9b7-dc95-41f9-8547-99d5e2eba874"}}}], "length": {"value": 0.029204400000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9a074422-3751-46be-a791-1c5831090b87", "name": "l(r:p1rdt7621lv-p1rlv16248)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60f0bddf-6e4b-495c-a98d-f3940d69a5e9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "feb24768-feab-40f0-acc3-0b2bb500133a"}}}], "length": {"value": 0.0226951, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8c4067c2-4a24-4294-b0b5-9e078686ce14", "name": "l(r:p1rdt7624lv-p1rlv16256)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e2075fb-9691-447e-9a73-f88649310bc1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32a9302f-2d40-4c2a-bde9-e4039694fed7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "0179bbe7-ed91-420f-bc7e-556355621ed5", "name": "l(r:p1rdt7625lv-p1rlv16257)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6b1e3b6-ce3a-4ad6-a046-6608530b2ec2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "935c99a6-bef6-4417-872c-0685011c440c"}}}], "length": {"value": 0.08197240000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b7d74205-f9f2-4629-b005-d28349a3ee52", "name": "l(r:p1rdt7626lv-p1rlv16260)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56f8eed1-77ae-4d65-80aa-7ae148350333"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdf35585-e2b3-4463-a6a8-acb352f25003"}}}], "length": {"value": 0.0157324, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "faadfdae-2d72-4662-91e7-ec1f7654ef6b", "name": "l(r:p1rdt7626lv-p1rlv16269)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56f8eed1-77ae-4d65-80aa-7ae148350333"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc746539-662a-4fe4-8774-6ba2dc538118"}}}], "length": {"value": 0.00987847, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5edfcfe0-2c44-4832-938e-e09b4621e7c1", "name": "l(r:p1rdt7627lv-p1rlv16262)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90d8891c-6e6d-46b9-8f88-acc9453c6541"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2797febc-f5e7-4cb3-b26f-ace990dc6920"}}}], "length": {"value": 0.00420024, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "18404b85-1ac1-4964-b5a4-69db35c99ef9", "name": "l(r:p1rdt7630lv-p1rlv16266)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ad2599f-313b-49c6-abaa-19177e1a9edc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8835446-b333-4be9-96bd-57ff9d01ebd3"}}}], "length": {"value": 0.0649914, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9c3cc8d2-c149-4fa9-8e26-1cfb3d5840fe", "name": "l(r:p1rdt7631lv-p1rlv16268)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4861056b-b634-4900-94bb-d6c995387351"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba6ebe7f-b6b9-4f89-8bbf-7bffd63e10ef"}}}], "length": {"value": 0.0412806, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "fe7937ea-1d97-4b06-ae00-05043b6f5450", "name": "l(r:p1rdt7699lv-p1rlv16416)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bfa76dc8-4007-4e52-9692-2eec7cb574e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f58421d6-268b-417f-a579-c9c51d010697"}}}], "length": {"value": 0.079141, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e329d231-586c-4da4-be1c-635869501cb7", "name": "l(r:p1rdm16862-p1rlv16395)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e60bfe9e-d2fa-4576-87f3-0a866b88d07d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d908890-4fe4-4349-92de-464c4165b185"}}}], "length": {"value": 0.0592066, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "468c39e1-9b75-4323-be99-3513b80c5ba1", "name": "l(r:p1rdm16862-p1rdt7699lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bfa76dc8-4007-4e52-9692-2eec7cb574e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e60bfe9e-d2fa-4576-87f3-0a866b88d07d"}}}], "length": {"value": 0.0187021, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ca527da2-14ed-422f-b70c-1bc7bd4d4a7e", "name": "l(r:p1rdt7701lv-p1rlv16397)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0cc95d09-c799-488e-81e8-50326a7da1ea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "323373a9-8e7d-4fb4-8970-dcc0e6d26c98"}}}], "length": {"value": 0.0805765, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f9812016-b945-4e02-8acf-7b54729433c8", "name": "l(r:p1rdt7704lv-p1rlv20070)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ef392d6-b408-4a7f-8a67-9fe43e1df582"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "571a4c92-95b6-4bc0-a25d-0d9239a41a89"}}}], "length": {"value": 0.0912722, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "69240808-930b-4994-9d23-dee6955da16c", "name": "l(r:p1rdm16872-p1rlv16401)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0797f1d0-3499-4f88-a749-fc576240f791"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eeb598c2-f0b9-44df-bfaa-be66e4dc3920"}}}], "length": {"value": 0.0257854, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "18b08e77-eb01-4b55-b1ce-98e572b7dd24", "name": "l(r:p1rdm16872-p1rdt7704lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ef392d6-b408-4a7f-8a67-9fe43e1df582"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0797f1d0-3499-4f88-a749-fc576240f791"}}}], "length": {"value": 0.0193937, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7cba66ff-a6ee-4381-9e47-2a5af2de3377", "name": "l(r:p1rdm16873-p1rlv20068)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5e00667-6368-49d3-a5dd-c574c79dba21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0b689f0-d4b1-4419-bff8-f72436625c60"}}}], "length": {"value": 0.0406184, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ba8749a8-823d-4c50-9058-f01580cfa960", "name": "l(r:p1rdm16873-p1rlv20069)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5e00667-6368-49d3-a5dd-c574c79dba21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f0e3c74-2d63-4612-b0e5-d986ebee0086"}}}], "length": {"value": 0.0750315, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9621505b-497f-4f4e-b57f-a04130b6eca0", "name": "l(r:p1rdm16873-p1rdt7704lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ef392d6-b408-4a7f-8a67-9fe43e1df582"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5e00667-6368-49d3-a5dd-c574c79dba21"}}}], "length": {"value": 0.019391500000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e7f8fc5c-5a80-4393-8e10-ac437b20b61d", "name": "l(r:p1rdt7712lv-p1rlv16412)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59a62487-c709-428e-9e97-c7c285a1305c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99f97a6b-4e94-4a35-ad00-12e7004ab5e3"}}}], "length": {"value": 0.0485398, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f0906201-838f-44bd-962b-5a532e582278", "name": "l(r:p1rdt7718lv-p1rlv16422)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6d10a4e-e7bc-4448-bca3-a5f2117b6198"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f367b63c-c4cb-4810-a270-8bd0153b7b32"}}}], "length": {"value": 0.013767300000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6fa6e077-a768-476b-84c5-2aa32a00b492", "name": "l(r:p1rdt7718lv-p1rlv16424)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6d10a4e-e7bc-4448-bca3-a5f2117b6198"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2242f1c-542f-4c1f-b3e6-19482cccde8d"}}}], "length": {"value": 0.013767300000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "067decd6-dc2e-405c-b604-7300ea1905a2", "name": "l(r:p1rdt7735lv-p1rlv16445)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96dcd934-01a0-4719-89bc-a18430edf179"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e090544-3c8e-4716-9dae-0b311a1017ea"}}}], "length": {"value": 0.0284282, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d86ce606-0132-488e-ba44-92843bfb8d12", "name": "l(r:p1rdt7790lv-p1rlv16570)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ed564b5-8d49-4ff7-94c2-b245981472e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53d578d8-8492-471b-8f66-233e489a3652"}}}], "length": {"value": 0.0553998, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7ea5b970-dc67-44e2-af2f-76936ea99183", "name": "l(r:p1rdt7954lv-p1rlv16905)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9dd5bb5-1410-4635-8a85-d23d7c3e55ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7578563f-d4b3-423b-a8f5-3ee91a042d19"}}}], "length": {"value": 0.0850821, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "00df3659-93b5-43ea-a55e-a0893faccc10", "name": "l(r:p1rdm17416-p1rlv16882)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e982887d-97c6-4af5-b536-a15a372b3379"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4faf40b9-9ade-45b5-ade8-3f1833605cd1"}}}], "length": {"value": 0.09884780000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "729ab8bb-81b7-460d-8b0e-e4f5ef25eda6", "name": "l(r:p1rdm17416-p1rdt7954lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9dd5bb5-1410-4635-8a85-d23d7c3e55ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e982887d-97c6-4af5-b536-a15a372b3379"}}}], "length": {"value": 0.0184307, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ef9a2339-09f7-486b-8e23-0b908af565b6", "name": "l(r:p1rdt7973lv-p1rlv16912)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3a96167-4b09-49c9-baf7-4fb588ecb002"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2308dc3-d10b-4049-862d-caf3356fa9a7"}}}], "length": {"value": 0.0637175, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2719d040-2a20-4bbc-bbf1-d5f6272f6310", "name": "l(r:p1rdt7973lv-p1rlv16988)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3a96167-4b09-49c9-baf7-4fb588ecb002"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11a633b0-2b09-4c66-94d4-d1c24cdd9cf5"}}}], "length": {"value": 0.0681669, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7cb3929d-dcf6-4fa6-bf71-8d2d79fbacd7", "name": "l(r:p1rdm17505-p1rlv16904)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53ed549a-9c24-4bdd-9e40-aee5308d8120"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c570ef7-c483-4c1e-b0fd-8712e8e9a7cd"}}}], "length": {"value": 0.0396092, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "792c1524-361f-42ca-81a5-8f88a601bd78", "name": "l(r:p1rdm17505-p1rdt7973lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3a96167-4b09-49c9-baf7-4fb588ecb002"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53ed549a-9c24-4bdd-9e40-aee5308d8120"}}}], "length": {"value": 0.0168466, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1313795b-a5f9-4cc6-a9c8-7943979110f3", "name": "l(r:p1rdt7983lv-p1rlv16919)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb63be48-94ec-4c9f-9991-77892e14171b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07e01053-37f3-4b9f-a9f1-d51bccd29803"}}}], "length": {"value": 0.079259, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "85650fc1-1735-4e05-8f26-86c5ca8437b9", "name": "l(r:p1rdt7983lv-p1rlv17033)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb63be48-94ec-4c9f-9991-77892e14171b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfa28657-cd8e-4700-a189-83e021f77bee"}}}], "length": {"value": 0.0492948, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0f5baa05-57eb-4dcd-b077-ae2d13649e82", "name": "l(r:p1rdt7986lv-p1rlv16922)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "415fe6e9-953e-40f6-8ae8-43834e4e6ce4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce315d98-1556-429b-aebb-0c868892396a"}}}], "length": {"value": 0.0143418, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "001d627b-af02-488f-b9c8-23280b783daa", "name": "l(r:p1rdt7986lv-p1rlv16957)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "415fe6e9-953e-40f6-8ae8-43834e4e6ce4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7dff1455-5154-429f-a33f-044d8501281d"}}}], "length": {"value": 0.0453768, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6476ae7e-8f41-498c-9da2-84e326f9d60a", "name": "l(r:p1rdt7986lv-p1rlv17063)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "415fe6e9-953e-40f6-8ae8-43834e4e6ce4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19130741-0fe1-4a12-8a55-96355609bccb"}}}], "length": {"value": 0.0371136, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e0da39bf-f183-4b18-9021-71a39d01f9bd", "name": "l(r:p1rdt7988lv-p1rlv16926)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94f12107-697c-4278-95e0-32b6eb49fdb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ba1d053-4462-4eb4-aca6-5ede38aa283c"}}}], "length": {"value": 0.00743277, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "150161df-4909-484b-95b0-d6b3d384dbc8", "name": "l(r:p1rdt7988lv-p1rlv17106)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94f12107-697c-4278-95e0-32b6eb49fdb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5439f343-8176-4d92-99d4-bb9209817f6b"}}}], "length": {"value": 0.00743277, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b7fe8781-6590-4253-9abb-c7288b33a95b", "name": "l(r:p1rdt8012lv-p1rlv16992)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5b22c57-7912-4e9f-9b06-6a8ff706a58d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57e8aa34-3967-4f22-a978-cb513c49c153"}}}], "length": {"value": 0.109333, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "93bde77a-daea-4cd1-9aac-96608150fd7e", "name": "l(r:p1rdt8012lv-p1rlv17069)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5b22c57-7912-4e9f-9b06-6a8ff706a58d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd48a076-5f8f-426a-b294-183700d1a123"}}}], "length": {"value": 0.0628588, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c75878bb-a8e9-45f7-ac9f-3112ab4daa2e", "name": "l(r:p1rdt8015lv-p1rlv17001)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6c5d7ff-cfcd-4b30-98db-eb44a95d6841"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f23214ee-3032-4403-9084-8117e89cb1cf"}}}], "length": {"value": 0.00814411, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4a06edff-3ac9-477f-afd1-857950e98149", "name": "l(r:p1rdt8015lv-p1rlv17028)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6c5d7ff-cfcd-4b30-98db-eb44a95d6841"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "213e6d98-ad57-4034-b2d0-4b096554cac2"}}}], "length": {"value": 0.00814411, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "963a379d-4526-40c4-a92c-040fcd1db98c", "name": "l(r:p1rdt8034lv-p1rlv17059)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "972fe574-f88e-4a8d-8845-d5baa2f378a7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "92aff718-b70f-4ea4-b38b-fae69a470c58"}}}], "length": {"value": 0.0530471, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "39ed0258-6338-449e-a516-59e9a08220e0", "name": "l(r:p1rdt8149lv-p1rlv17319)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9951633b-4311-4ca2-9316-3801be13fe97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9778ed5-f0c0-44de-b0d4-60659a54fa3b"}}}], "length": {"value": 0.0160827, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cee2f792-d80f-4b98-a645-57496b1a1a4e", "name": "l(r:p1rdt8149lv-p1rlv17334)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9951633b-4311-4ca2-9316-3801be13fe97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4970bc03-bc57-4a42-b0cb-66002af1709e"}}}], "length": {"value": 0.016006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1df0e133-12a9-410c-ac98-560dfc4918f0", "name": "l(r:p1rdt8150lv-p1rlv17320)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cd1ae47-6aaa-4b57-ba44-1e74f6ea54b7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79991b02-c0f1-4b9b-a55e-e9b4ff7c17d9"}}}], "length": {"value": 0.063086, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "815c3299-4558-40b9-b5fe-d5f0c27c11d7", "name": "l(r:p1rdt8150lv-p1rlv17326)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cd1ae47-6aaa-4b57-ba44-1e74f6ea54b7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ceb2d77-2da7-44df-9f28-69ed35835775"}}}], "length": {"value": 0.063086, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "499d0139-fa5c-45de-864f-e28786ab80fa", "name": "l(r:p1rdt8151lv-p1rlv17321)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a8deb5-b46b-4d4c-876c-b44b2258a6fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "00ed745d-78ae-47f6-b6ef-4edf8794ca6a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "4d608ad4-d94a-4b0b-8fcd-3c08ae50178c", "name": "l(r:p1rdt8151lv-p1rlv17321)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "00ed745d-78ae-47f6-b6ef-4edf8794ca6a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94ce8ee2-6f57-407a-93e9-c06f79d66262"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "4dceb5ed-b8a7-4331-90f0-5f93186eeaba", "name": "l(r:p1rdt8151lv-p1rlv17321)_s2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94ce8ee2-6f57-407a-93e9-c06f79d66262"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce41ac7c-06c5-435a-957d-c9dda83c1893"}}}], "length": {"value": 0.09433530000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d09084bb-a89a-4254-a73c-e94d3dc90fbd", "name": "l(r:p1rdt8151lv-p1rlv20188)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a8deb5-b46b-4d4c-876c-b44b2258a6fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abb24254-be79-45d4-8d9b-246b3e89c00f"}}}], "length": {"value": 0.00615959, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4ef03455-4b06-4b8f-af90-475cc6a09a60", "name": "l(r:p1rdt8153lv-p1rlv17325)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a542ca5-b24e-44dc-8b68-c00aa024afad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b96606c-9336-4299-be8d-295c84943a9d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "23108ceb-470b-432b-b6c3-701d156a5397", "name": "l(r:p1rdt8154lv-p1rlv17328)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32fefbef-e10b-4758-8c2e-ccafad49aa5d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a43eb022-d5e0-47c8-aa36-6ca0d212ab07"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "36ad5faf-d994-41eb-afb8-9a4fb8edcf6c", "name": "l(r:p1rdt8155lv-p1rlv17329)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51812cd8-eec8-4862-8413-d25a7e9862dc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61ef37c1-f14f-4b79-a428-d51a6f0d076a"}}}], "length": {"value": 0.0793038, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b52124cd-a5c9-4f18-9f6d-79b8143d4cef", "name": "l(r:p1rdm17903-p1rlv17330)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb2a5041-28a1-4fda-905b-caf53ebbefe3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48ad7bb0-8dd7-457a-b77d-6db2071c2fe7"}}}], "length": {"value": 0.0025319, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "11874623-6a90-44c5-b716-1180ab27ebdb", "name": "l(r:p1rdm17903-p1rdt8155lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51812cd8-eec8-4862-8413-d25a7e9862dc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb2a5041-28a1-4fda-905b-caf53ebbefe3"}}}], "length": {"value": 0.0391228, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a670c5be-e502-4ee5-bab3-d6830776dd9c", "name": "l(r:p1rdt8157lv-p1rlv17333)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa6d4429-8a95-4ebd-9e3a-9867734245bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33b66eb9-3b21-4f92-b19b-6a0eef4134d8"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "3c168ea4-60f1-40d7-9105-c60ebe5c0919", "name": "l(r:p1rdt8159lv-p1rlv20480)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1dd4660-3cd0-4709-b1ef-1c598e5e39fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5d0a174-d49d-4c7e-a669-092f6408edf4"}}}], "length": {"value": 0.0224012, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "42b10885-9f84-40fb-8096-ecdeabc0172c", "name": "l(r:p1rdm17907-p1rlv17336)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3484e698-3a4e-4a88-aaa3-1dc88cd9ac89"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b645969-9136-42a9-b5ac-7d2f1ff71959"}}}], "length": {"value": 0.0155741, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "711295b2-6d63-413f-8284-ba2877d64e97", "name": "l(r:p1rdm17907-p1rlv20492)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3484e698-3a4e-4a88-aaa3-1dc88cd9ac89"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7af262b7-285c-4d06-b7ff-2f2a1971055a"}}}], "length": {"value": 0.049942, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "daa257f3-0092-4324-ba2d-11ec7a94a4a1", "name": "l(r:p1rdm17907-p1rdt8159lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1dd4660-3cd0-4709-b1ef-1c598e5e39fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3484e698-3a4e-4a88-aaa3-1dc88cd9ac89"}}}], "length": {"value": 0.018672500000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2cbdeb9d-3636-4393-9326-b0240390e325", "name": "l(r:p1rdm17908-p1rlv20455)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6112cc26-bc37-4c72-8ef6-cd88f1296693"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8934db59-0c39-4838-9f8c-59a563cd9d54"}}}], "length": {"value": 0.0215008, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "06e87fff-fd19-45b8-bb9b-8cd0c6413c5a", "name": "l(r:p1rdm17908-p1rdt8159lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1dd4660-3cd0-4709-b1ef-1c598e5e39fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6112cc26-bc37-4c72-8ef6-cd88f1296693"}}}], "length": {"value": 0.0175631, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9a093498-1758-4c33-8c70-ea251e449258", "name": "l(r:p1rdt8160lv-p1rlv17337)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "232fed6b-fe0f-4a44-93e9-e6675b50c39c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5d7049e-9d30-474c-9033-3ad9b4487f7a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "259d0df0-c158-431c-8a14-d3db5f371846", "name": "l(r:p1rdt8161lv-p1rlv17338)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac7e489e-7249-4702-9ed6-131cad34500f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "331389ab-5d04-4648-83b4-3043198c774f"}}}], "length": {"value": 0.05601040000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "56875cf5-044e-43c9-b940-eee8bd16a486", "name": "l(r:p1rdt8346lv-p1rlv17702)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9560197a-21d1-4601-8bcb-213df4844f4a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7acb4e7d-cb06-4848-952d-7c68bb34b6db"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "e6dddecc-acad-4d45-849a-d67e98fe7205", "name": "l(r:p1rdt8405lv-p1rlv17781)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "408d5d7b-fc71-46bb-8de0-2d4e628c29b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a52db2ff-b782-40c1-828a-c65f6929b2fc"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b38ef92b-b5a5-4354-a862-4ff2cfcaf0e2", "name": "l(r:p1rdt8408lv-p1rlv17787)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3fe0f77-a7c1-48e3-94aa-30b69f20ca65"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c9c1d9f-eeff-454f-b3d0-7e7de837694c"}}}], "length": {"value": 0.030519200000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d2fdb455-533e-494f-b3ae-7a6f434a6456", "name": "l(r:p1rdt8408lv-p1rlv18044)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3fe0f77-a7c1-48e3-94aa-30b69f20ca65"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b40fac8c-a99b-4baa-940a-26565ba7d62b"}}}], "length": {"value": 0.030519200000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2cccc34f-8ec9-4a07-94e6-5ea9394c8395", "name": "l(r:p1rdt8414lv-p1rlv17798)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fca92353-c013-4c41-8507-ec8704410834"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9dba02d-086c-4906-9c6f-86532e3384c0"}}}], "length": {"value": 0.0626486, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3fa99df5-af3e-4d19-92fe-6c6b8fa2435f", "name": "l(r:p1rdt8422lv-p1rlv17810)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfe35c35-8164-4825-81e3-10a2ece2cb27"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3887a879-0783-4703-8a24-32b7e3b4f39d"}}}], "length": {"value": 0.064621, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "29fcd1b6-7f66-4926-8f32-6b14ca47aa39", "name": "l(r:p1rdt8422lv-p1rlv17847)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfe35c35-8164-4825-81e3-10a2ece2cb27"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f7776e4-a81f-48d2-b3c0-d70bfa48164e"}}}], "length": {"value": 0.114619, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6a2c3743-a96c-4193-afff-9f66a9993e4a", "name": "l(r:p1rdt8422lv-p1rlv17876)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfe35c35-8164-4825-81e3-10a2ece2cb27"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75e55237-b847-4fb7-a141-a0771bd868c6"}}}], "length": {"value": 0.0889709, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1cfd7122-29e2-4593-8a29-d37c7bab1574", "name": "l(r:p1rdm18545-p1rlv17961)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7421f5c-bf5c-4d01-aa14-ba657f242080"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2716887e-1701-4a78-805b-96da0781c7f8"}}}], "length": {"value": 0.07666780000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1fc0a354-eb4d-4fef-b7b3-9ac5204835bf", "name": "l(r:p1rdm18545-p1rdt8422lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfe35c35-8164-4825-81e3-10a2ece2cb27"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7421f5c-bf5c-4d01-aa14-ba657f242080"}}}], "length": {"value": 0.0192775, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6813915a-9540-4a06-8171-305ffaddeb8f", "name": "l(r:p1rdt8434lv-p1rlv17857)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdc5ef2a-c0d0-4702-b6c6-df08af1e8746"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0827675c-2467-403d-822e-5f74cd6296c5"}}}], "length": {"value": 0.0235179, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ae004d86-bb53-4a39-b217-28aba419df2a", "name": "l(r:p1rdt8436lv-p1rlv17877)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b24c9345-625f-499d-96cf-30b2de5839b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f44b0293-61e5-4054-b2d7-4a113df92b3c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "90848665-6e77-434a-9664-022c4b37b0ca", "name": "l(r:p1rdt8439lv-p1rlv17897)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a38f544-e250-4fc9-942c-946c5cde0a33"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f74f217-4765-406d-9646-d8f46377ef0a"}}}], "length": {"value": 0.0231504, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "615ebf6f-8bb0-491b-a80f-70ff9109b5c5", "name": "l(r:p1rdm18631-p1rlv17909)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6460e5c-839d-4f9e-b9d6-b187fddb9ab6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab733d49-bb36-4631-8824-1967f98f758a"}}}], "length": {"value": 0.055777700000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9d77603e-e62a-40c8-8d7b-5150e4e96a38", "name": "l(r:p1rdm18631-p1rdt8440lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "049362b4-49de-4e80-921e-ff763aaab2d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6460e5c-839d-4f9e-b9d6-b187fddb9ab6"}}}], "length": {"value": 0.017871200000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "48a7466b-1d73-416b-809a-83537dd3441d", "name": "l(r:p1rdm18632-p1rlv17969)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7633fe6b-a48b-4e7d-90e6-a38b8a861936"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ccaf70a-35d8-4f16-b632-e282fe30b5ca"}}}], "length": {"value": 0.018069200000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "19cb6fa7-25c3-47ca-a366-957be38b8701", "name": "l(r:p1rdm18632-p1rdt8440lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "049362b4-49de-4e80-921e-ff763aaab2d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7633fe6b-a48b-4e7d-90e6-a38b8a861936"}}}], "length": {"value": 0.0178577, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2caa96e4-c274-43dc-b1e4-5f11301d9ccf", "name": "l(r:p1rdt8441lv-p1rlv17912)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72c8f08a-0ba5-413e-a805-f9436b41ff29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3eb66d3-0271-4842-8893-9a58f64e0279"}}}], "length": {"value": 0.009300020000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "323d26e7-5b43-454b-a45c-aec7e307de9d", "name": "l(r:p1rdt8442lv-p1rlv17926)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b5ae28a-95f8-4023-aa23-36809fe96b10"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2812bbb1-0bb0-499f-a394-0995784bb7bc"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "186217d6-9a20-48aa-9949-c80f28bafe57", "name": "l(r:p1rdt8444lv-p1rlv17960)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "978920e8-edf9-4bee-85f9-45f4081ed0ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "215a5974-e23b-46f0-bde9-f5ad16fdfaf8"}}}], "length": {"value": 0.00946867, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a2666500-718c-4b6a-b104-d85550e22cdc", "name": "l(r:p1rdt8444lv-p1rlv18071)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "978920e8-edf9-4bee-85f9-45f4081ed0ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86917829-123c-4fda-9809-dc61430a9fef"}}}], "length": {"value": 0.00946867, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "af700dca-e6b2-417d-a811-cc93dc290724", "name": "l(r:p1rdt8445lv-p1rlv17962)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e0923da-550b-479f-b3d8-3e0320db6701"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec99daac-e0be-4ea1-ba4f-185d4943396d"}}}], "length": {"value": 0.07683860000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "529ee728-9a14-4ce5-bbf5-baa1001689c5", "name": "l(r:p1rdt8447lv-p1rlv17987)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5dbc3459-6a17-4075-899a-6aab16fb3ab7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0771ebfa-5eaf-4ae8-94f1-86de7a656f58"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "04dd8850-4fe7-4c15-8a87-50bc76145038", "name": "l(r:p1rdt8450lv-p1rlv18053)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b4216c8-9e99-446c-ad09-5a09f046dd59"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4aeda1c7-41be-43c8-82e5-d7a347db86a8"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "63c8dbef-8a8b-4ce8-95cf-6fc4728d963d", "name": "l(r:p1rdt8456lv-p1rlv18100)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d094b779-ebcc-4837-9ccb-31808e2a544b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4863d28-4ee2-479d-accb-60b54f472fe7"}}}], "length": {"value": 0.04190880000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "300dd493-34b4-4375-892d-eadd8fe22746", "name": "l(r:p1rdt8458lv-p1rlv18129)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e597d8da-e876-44a5-a109-1ce84527c557"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "115a848f-f6f3-48f0-9f33-5a9103f1a892"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "43c4c411-e502-46b8-9442-5f4d7dd2ea62", "name": "l(r:p1rdt8470lv-p1rlv18166)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "edb15d92-f98a-4fa2-8129-ad8a39e0dc0c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "431692e5-2917-41ea-aafc-96be180b7e27"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "be9ad055-8cbd-4405-8241-9bc60395472f", "name": "l(r:p1rdt8490lv-p1rlv18192)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a84e1424-7faf-4077-9461-b39460f10ef0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c3e08a8-ea88-423d-b361-69509f7ab8fa"}}}], "length": {"value": 0.0095095, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bdc387c3-9bdc-43d9-890f-0d718eba7c3a", "name": "l(r:p1rdt8490lv-p1rlv18198)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a84e1424-7faf-4077-9461-b39460f10ef0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a7cb078-af6c-4cd5-9aca-48f515f6e711"}}}], "length": {"value": 0.0095095, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f668b67f-606b-4d28-9cc3-1943007f22e4", "name": "l(r:p1rdt8492lv-p1rlv18197)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "127e4cc7-6413-4482-9ec3-40f8bde02d0c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5e240e8-b27d-4181-a7ee-a004d3f5c58a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "81b9170e-c68f-4cac-a3d4-fbc567e0a98c", "name": "l(r:p1rdt8802lv-p1rlv18960)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95a1a7c7-6055-47c9-a742-c1b81f6c7478"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9178fdee-311f-40f5-bdd6-9b474a05247e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "5c797127-ea67-442a-b638-200eacfd668c", "name": "l(r:p1rdt8805lv-p1rlv18967)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "715c92fa-2470-4869-8d5f-0b4f3f8360d4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eef4f0cf-6e51-45e1-8b6e-84171f7cbef6"}}}], "length": {"value": 0.0733915, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "dd30ae2e-bd36-4ebb-abb3-ba2b2c134191", "name": "l(r:p1rdt8898lv-p1rlv19157)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6ff626c-d2fc-4b97-9013-4fd544d946a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cf28b5d-d8d4-4883-a396-2d1ad9b70564"}}}], "length": {"value": 0.0657162, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "147a1cb3-41c2-49b8-8b56-b4683e957a72", "name": "l(r:p1rdm19752-p1rlv19149)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09d59048-6e1b-4f7f-b161-81163809eb25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67a4600d-65c3-40d7-ad28-e8e37ff77dcb"}}}], "length": {"value": 0.046789, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "0ca56993-e151-46ec-bc06-2732eef8e2a4", "name": "l(r:p1rdm19752-p1rlv19160)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09d59048-6e1b-4f7f-b161-81163809eb25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7c1d210-ee87-46c5-b408-ad221cbeed04"}}}], "length": {"value": 0.057637900000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "d4f9decd-9338-4453-85d3-5c8b5ac0490f", "name": "l(r:p1rdm19752-p1rdt8898lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6ff626c-d2fc-4b97-9013-4fd544d946a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09d59048-6e1b-4f7f-b161-81163809eb25"}}}], "length": {"value": 0.019358300000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "cb6ddaa3-2b16-42bd-bce5-bd8a267eab2f", "name": "l(r:p1rdm19755-p1rlv19166)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7664d29-bbc0-4465-a00a-82af048b86e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "994f6392-f4e5-4ff8-9eeb-5849cd035912"}}}], "length": {"value": 0.0880892, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "6a7bb342-4fcd-424d-861f-0ee25541d40f", "name": "l(r:p1rdm19755-p1rdt8898lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6ff626c-d2fc-4b97-9013-4fd544d946a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7664d29-bbc0-4465-a00a-82af048b86e5"}}}], "length": {"value": 0.0437869, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "f229b79a-47fa-4ab8-9ea2-b416d4caf8fc", "name": "l(r:p1rdt8901lv-p1rlv19161)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d53c0a2-78cc-4988-85a4-884ef039f5fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16df6b90-d049-4160-b148-b888e03acb82"}}}], "length": {"value": 0.0671759, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6bdd0d1e-8826-457f-a773-5a2a945a84ce", "name": "l(r:p1rdt8904lv-p1rlv19168)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e111e213-bcbe-42c4-b6ab-2c734ff5341c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f8c76ca-40ea-4f7d-8042-66edd484f065"}}}], "length": {"value": 0.045782800000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "741a9472-dbc2-427c-a02b-462c15f35f7b", "name": "l(r:p1rdt8904lv-p1rlv19174)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e111e213-bcbe-42c4-b6ab-2c734ff5341c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0fc7d43-4f82-4100-99bf-6e30e03e95ce"}}}], "length": {"value": 0.0128136, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "96ca1afa-d534-4724-8ecb-b6702cfd67b7", "name": "l(r:p1rdm19776-p1rlv19184)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b9386f2-376d-4439-a9a4-3eefc238dafe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50750ddb-80db-4d5f-bc62-4bbfc600a7ef"}}}], "length": {"value": 0.075847, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "72bd06c1-2522-4912-ab13-24cec5f2b774", "name": "l(r:p1rdm19776-p1rdt8904lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e111e213-bcbe-42c4-b6ab-2c734ff5341c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b9386f2-376d-4439-a9a4-3eefc238dafe"}}}], "length": {"value": 0.010418900000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a90947b1-4fd1-4387-bdff-d59c20a3fb90", "name": "l(r:p1rdt8905lv-p1rlv19169)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2777cc-f3fd-491f-a10b-4ed381cb948d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4e8183-9148-477e-aa1b-ff31a5324273"}}}], "length": {"value": 0.0299426, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "04d7afca-c271-4057-ab48-201ee8bcd8a3", "name": "l(r:p1rdt8905lv-p1rlv19171)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2777cc-f3fd-491f-a10b-4ed381cb948d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fffe26f7-c4cc-420e-ab17-754cb0d9e659"}}}], "length": {"value": 0.0502658, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "21e7a836-3ea5-407e-bd70-f3443102eebd", "name": "l(r:p1rdt8905lv-p1rlv19173)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2777cc-f3fd-491f-a10b-4ed381cb948d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21fec301-b67c-4042-a074-caf406c7f0b5"}}}], "length": {"value": 0.0431542, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7c1587be-1e8f-466e-8791-3a41354606c0", "name": "l(r:p1rdt8905lv-p1rlv19188)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2777cc-f3fd-491f-a10b-4ed381cb948d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47e24942-486d-46f1-a40f-0da5c93c013a"}}}], "length": {"value": 0.00975868, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4637e31d-b157-4290-a8cb-4596fb7db783", "name": "l(r:p1rdt8905lv-p1rlv19194)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2777cc-f3fd-491f-a10b-4ed381cb948d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7daa1d3-6249-447d-a260-65de5ec0a470"}}}], "length": {"value": 0.0629287, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3bca6f74-5988-47c8-a80c-3cd6b0a69bb6", "name": "l(r:p1rdt8911lv-p1rlv19183)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c306f79a-0240-465e-a486-d0f11614fc57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "89bde057-807b-415c-9135-267c6bf43c44"}}}], "length": {"value": 0.0132248, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7550f50f-c63b-48ad-8fdd-dc45f65120ce", "name": "l(r:p1rdt8911lv-p1rlv20296)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c306f79a-0240-465e-a486-d0f11614fc57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a8ae6dc-884d-48d8-9995-fe3936ad019c"}}}], "length": {"value": 0.0132248, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "418f522f-9800-4e1d-a31b-cf04a40a6664", "name": "l(r:p1rdt8915lv-p1rlv19189)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2fbbca23-6473-4344-ac2e-cc97078b3d8d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5fecc64a-4783-4ecb-a0d0-7e60d1cf6184"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "632311c1-925c-4de3-92fc-6b27efe14c9f", "name": "l(r:p1rdt8916lv-p1rlv19190)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d268e33-708d-4bae-8348-cad27fd0d81a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4aee02d4-8663-455b-a197-55b6b1470895"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "40f4ca55-ed5c-4973-971b-35cd67ba354e", "name": "l(r:p1rdt9075lv-p1rlv19667)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6752e8f4-9e37-476d-aec2-4a2fe7c1e2dc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33dcb037-4cc8-480f-aac4-bc95e54e165e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b4340e3d-5abb-4a2e-ab02-77baaf44385e", "name": "l(r:p1rdt9076lv-p1rlv19698)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdd64386-e256-47f8-8cef-1c933f993a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14b1ab4e-b22d-4a98-8131-fc72c923c735"}}}], "length": {"value": 0.055055700000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7a80ce41-b341-4153-b901-ce184294afbb", "name": "l(r:p1rdm20204-p1rlv19668)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd00c91a-01a8-4aad-b740-b06a654d631b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6427f66-2e22-40bb-83f1-2a8b1be9191a"}}}], "length": {"value": 0.0202803, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "049118fd-f5d6-4f65-9749-8f71e013199a", "name": "l(r:p1rdm20204-p1rlv19699)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd00c91a-01a8-4aad-b740-b06a654d631b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48654a82-ac11-4542-94ec-8f731138e1a8"}}}], "length": {"value": 0.0338608, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2c76a5dc-ab24-4233-b561-76095bf798b1", "name": "l(r:p1rdm20204-p1rdt9076lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdd64386-e256-47f8-8cef-1c933f993a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd00c91a-01a8-4aad-b740-b06a654d631b"}}}], "length": {"value": 0.0174413, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "eb46a639-7f1d-4e52-9a81-3b86dadfb400", "name": "l(r:p1rdm20205-p1rlv19686)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce8f50bb-90fb-49b8-8a16-1bbbb6a0c82c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47f5777d-2c8d-48c2-bf28-386f3f3dbac4"}}}], "length": {"value": 0.0229841, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "172f2ac8-d408-43a5-8f2f-85b7eb96c199", "name": "l(r:p1rdm20205-p1rdt9076lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdd64386-e256-47f8-8cef-1c933f993a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce8f50bb-90fb-49b8-8a16-1bbbb6a0c82c"}}}], "length": {"value": 0.017440300000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "642532af-cf6d-4892-bfa9-52b019bfbf8a", "name": "l(r:p1rdt9077lv-p1rlv19669)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b83eaaa-a092-42ca-a746-db4d9658d62b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96d3079a-02f1-4c89-ad75-fd0a438c9cf4"}}}], "length": {"value": 0.0293066, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b1bf45c3-70c8-4201-8c1a-d7d811dc7e70", "name": "l(r:p1rdt9077lv-p1rlv19675)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b83eaaa-a092-42ca-a746-db4d9658d62b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0031ab1b-d82d-40a5-b41e-bc6f6cb53069"}}}], "length": {"value": 0.00129939, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "a2668d78-c842-45e2-aeba-92c501e738bf", "name": "l(r:p1rdt9077lv-p1rlv19695)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b83eaaa-a092-42ca-a746-db4d9658d62b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35fe21a1-f817-426e-9e42-f1f33876dd7d"}}}], "length": {"value": 0.0295629, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7c77322f-3c54-4db1-b408-c1bcda2a0af3", "name": "l(r:p1rdt9084lv-p1rlv19681)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f0e4f59-8a46-4abf-9f06-e0383a59a45d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83afc678-d577-4ef1-afa2-8e3f915a158b"}}}], "length": {"value": 0.0407307, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ef70211b-06c5-4723-acbc-8f9aa7fe7d51", "name": "l(r:p1rdt9085lv-p1rlv19682)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "565bbfb1-a28f-4db2-be48-cbd58972025a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "811acd48-b61c-4a42-b76e-f995961c450e"}}}], "length": {"value": 0.0479288, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3052d3d1-b680-42ca-9619-45b322a57260", "name": "l(r:p1rdm20223-p1rlv19701)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec27727b-2bb8-4df2-9ddf-46282728c2c0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b5d936f-b3e0-408e-aabd-d3ebb7b869b0"}}}], "length": {"value": 0.05942600000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8693b634-c1ba-4076-b23e-61ae440e0c6b", "name": "l(r:p1rdm20223-p1rdt9085lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "565bbfb1-a28f-4db2-be48-cbd58972025a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec27727b-2bb8-4df2-9ddf-46282728c2c0"}}}], "length": {"value": 0.0186112, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4af17e9c-30e9-42ab-a616-44bee74bb9ea", "name": "l(r:p1rdt9089lv-p1rlv19689)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8108ac8-2807-4a40-85c2-db21efaadadb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "578b5df8-1dd8-41d9-b6dc-db75db5b115e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "a1434937-97ae-4da2-89f7-ebd1a788eb6a", "name": "l(r:p1rdt9090lv-p1rlv19690)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fc84159-09b1-4ca9-9a7a-a4fecab19f83"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2709a70-1a7d-454c-90fd-377e416a0071"}}}], "length": {"value": 0.0658315, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "67edc557-f853-458b-902b-2b073085da46", "name": "l(r:p1rdt9091lv-p1rlv19692)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e93ea18-150d-4d80-bac7-f3e1b87c5b4e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b10b272a-2efb-4e19-9921-d4081fb45778"}}}], "length": {"value": 0.0495767, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "86030b36-5fb5-416e-9704-398ab3aab79f", "name": "l(r:p1rdt9093lv-p1rlv19702)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f0726b7-3050-4c78-9c06-b9fd0c863ff3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37f72c85-61f7-4a42-94b0-6a627195458c"}}}], "length": {"value": 0.0423003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "41164760-4968-427a-ab0d-54100e9f5dc4", "name": "l(r:p1rdt9264lv-p1rlv20064)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c01a9b2-b002-4279-905e-950452f64f32"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aaea76fa-797e-46c5-a70f-a973977db841"}}}], "length": {"value": 0.0166628, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5e7381fe-5c31-423e-aa3a-7d6619d0c6d3", "name": "l(r:p1rdt9264lv-p1rlv20065)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c01a9b2-b002-4279-905e-950452f64f32"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea48ffa1-bdb3-4c15-96c9-ff7d7f34824f"}}}], "length": {"value": 0.0166628, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b84af902-253c-4e92-9494-157b730e98d1", "name": "l(r:p1rdt9265lv-p1rlv20066)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "77d62813-61d3-4afd-9f21-869e2ea23e17"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f450eeb4-3d87-4ae5-a6d6-958d7efd2712"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "2f422366-4e22-4f2c-8d50-1c6ba8a3374c", "name": "l(r:p1rdt9266lv-p1rlv20067)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78278589-be2d-4d99-9c03-92c221348917"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66a710fb-26c7-4465-b7ea-43ec107008dc"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "4f7d87f3-0ea4-4d93-b95a-cbe87c41dbc3", "name": "l(r:p1rdt9298lv-p1rlv20130)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "208f222c-45db-445f-ba0b-a4a195ca68a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ffc82be6-f3f8-4a68-b6e6-da60b137329c"}}}], "length": {"value": 0.0378956, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "bfcb695e-ecef-4564-813d-f2cb6bad6682", "name": "l(r:p1rdt9302lv-p1rlv20138)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180fad26-0e7d-4e2c-ba17-c8e3315ca278"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d635a151-2d13-47e9-8043-a214415a5b5e"}}}], "length": {"value": 0.057895600000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "39176fb1-de94-4c16-b64e-596ad25ee5f4", "name": "l(r:p1rdt9310lv-p1rlv20146)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4940a0e-dcc2-45fb-baa9-aadc84f8e882"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d615e93-a289-41ec-bda0-3b72bf15677e"}}}], "length": {"value": 0.052341200000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "71d34c49-4330-4c50-990a-3197e3ca5532", "name": "l(r:p1rdt9311lv-p1rlv20147)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9e0aa7d-9097-4370-8f5e-52a5885da85c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16b2add7-6a6d-4359-ad6f-f60edf435a4c"}}}], "length": {"value": 0.0259737, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8f3ee985-bbf9-4676-98e9-06a7c1d0a3d7", "name": "l(r:p1rdt9311lv-p1rlv20163)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9e0aa7d-9097-4370-8f5e-52a5885da85c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e938635b-e0d2-4e1b-a312-5a8f51e1dd7a"}}}], "length": {"value": 0.0357477, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ef39c360-8161-46c8-91bb-76651bc2d55f", "name": "l(r:p1rdt9312lv-p1rlv20148)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a21f5ca-51ef-4f81-8229-163182f011cf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4a0c2f2-f75e-4c9c-b3f7-d8d9ada9cb82"}}}], "length": {"value": 0.0268922, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3e7fdcaf-686b-496f-b34f-388785ad42a5", "name": "l(r:p1rdt9312lv-p1rlv20160)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a21f5ca-51ef-4f81-8229-163182f011cf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27dfea92-734e-49d3-b245-dc933df66889"}}}], "length": {"value": 0.0268922, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bc01fb01-4d37-4631-af7f-19d7e8269bbb", "name": "l(r:p1rdt9314lv-p1rlv20473)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3df13d91-365e-411b-917d-b28df5989280"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3eb214b9-827f-4995-a862-907be02b029d"}}}], "length": {"value": 0.0624435, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f48d1d5e-4709-4de9-b25d-ef596616a9fe", "name": "l(r:p1rdm20686-p1rlv20151)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5930295-0e44-4498-ae22-7647b72c1fa1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "956f4975-7383-4e0b-9114-d333a6ec4005"}}}], "length": {"value": 0.0773067, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c8ae9e69-9a3a-410a-9fd2-5ad1838b01c7", "name": "l(r:p1rdm20686-p1rlv20456)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5930295-0e44-4498-ae22-7647b72c1fa1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7a43aa6-2be8-4320-8089-57d388633c6b"}}}], "length": {"value": 0.0422263, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "97870ca0-fce4-48b0-85c2-87b76b884161", "name": "l(r:p1rdm20686-p1rdt9314lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3df13d91-365e-411b-917d-b28df5989280"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5930295-0e44-4498-ae22-7647b72c1fa1"}}}], "length": {"value": 0.0198942, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3435161e-0808-453b-ade5-697634ed4656", "name": "l(r:p1rdt9316lv-p1rlv20153)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c97a99f-545b-49cd-b1fe-4fd9e04bf37f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef20846d-d685-4c65-8dfb-bc23317501c5"}}}], "length": {"value": 0.021752800000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "633b6dd6-6a15-47ed-9d97-aebf2d9b5b6d", "name": "l(r:p1rdt9333lv-p1rlv20182)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a68a1c01-a04c-4af6-b1c8-02ddd1d67e0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20f93381-3834-4265-b1ec-5767d171ce0a"}}}], "length": {"value": 0.0263788, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b3b2c026-7b70-40e5-8478-180fd8809d5e", "name": "l(r:p1rdt9377lv-p1rlv20277)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e98299cb-8bad-49ea-8627-f3cfe01b9e23"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb7a8747-a076-469c-a150-35f6763157ec"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "087026c8-269c-4769-9c6f-af9a90b11306", "name": "l(r:p1rdt9381lv-p1rlv20281)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e37f182-5a60-470d-8f5b-ba145cc27973"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f23405b-432f-45ff-a7b1-0b7147cddfc8"}}}], "length": {"value": 0.0253793, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "59b8b45a-c9f3-49e3-8323-0d7dd87f9cb1", "name": "l(r:p1rdt9381lv-p1rlv20309)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e37f182-5a60-470d-8f5b-ba145cc27973"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e5718ad-0b70-4ea4-b2f2-31f0ea5c5d5b"}}}], "length": {"value": 0.0253793, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "26c34058-4892-4440-845b-5d3851809b0c", "name": "l(r:p1rdt9384lv-p1rlv20284)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abd09ea6-221c-47d9-beec-1062e0dd4aa7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25837ab0-0fb8-4346-94ad-561ff9ff7f0c"}}}], "length": {"value": 0.00420309, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9c16c054-b1ff-4e91-9010-39b32b8e0c3c", "name": "l(r:p1rdt9396lv-p1rlv20300)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc7e0a25-d6d6-4b07-b3dc-4fe5646915e2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da62d78e-e221-423a-8da0-8d36ce1f7508"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "d348f254-0831-467d-a2cf-24cff48b1fdc", "name": "l(r:p1rdt9413lv-p1rlv20333)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8180ee90-a46e-4d85-9742-d47b24f5e169"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c23afdc0-ab93-4d43-8eec-613eab21cd74"}}}], "length": {"value": 0.055563600000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d39e9443-e092-4bb9-890c-ec952b4704b1", "name": "l(r:p1rdt9413lv-p1rlv20358)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8180ee90-a46e-4d85-9742-d47b24f5e169"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b5d2dfa-895b-4afc-a7fe-449960adba41"}}}], "length": {"value": 0.055563600000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "5bf01fa7-0a38-4b2d-b944-93837af9be6a", "name": "l(r:p1rdt9463lv-p1rlv20432)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a015abb-ec63-4b31-9314-283b8499646e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4b5327a-85a3-496c-859c-f887a38513cd"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "e58c5ea4-bad0-4ebb-8dbd-9ba73b522dc9", "name": "l(r:p1rdt9468lv-p1rlv20451)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4dbe1628-cd17-4f37-af2b-dd752c290fa4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c37708d8-1e83-4e76-ac7f-0d29ba6b7c4e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "d36d6ce0-a328-49e6-8589-761a2846b82e", "name": "l(r:p1rdt9469lv-p1rlv20453)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09613257-d4cb-4c50-b35a-8aefc637c0c9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4e21b79-d2be-4a53-be46-32331e61f89c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "607be846-24c7-4d25-9222-e26430fd02e8", "name": "l(r:p1rdt9470lv-p1rlv20459)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1ab8727-2758-4513-8a7d-e02381faf1e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dfcfdbf-0051-4eef-bea6-97446cee21e4"}}}], "length": {"value": 0.0117286, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "03097dee-3563-430d-b479-e6da3aad6765", "name": "l(r:p1rdt9470lv-p1rlv20499)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1ab8727-2758-4513-8a7d-e02381faf1e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af153ed-ed39-4433-ac12-19dfdb7b6bef"}}}], "length": {"value": 0.0117286, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "abbb58b1-e018-43c7-8d8a-c43034cd923f", "name": "l(r:p1rdt9473lv-p1rlv20465)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c14c3211-a0d5-464f-820c-cab04764d907"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4759390d-43ec-45c9-9cca-320020dc1150"}}}], "length": {"value": 0.0334443, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4d466a6c-7eae-4477-a58b-84b46559fe6e", "name": "l(r:p1rdt9479lv-p1rlv20502)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6a8f268-6a5a-4b23-bd91-53c6b031442a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cacd3e49-55aa-4f05-bd7d-ae8aba0af87f"}}}], "length": {"value": 0.0132405, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "35f3ce10-7ea2-43a6-92f7-0e66c65507eb", "name": "l(r:p1rdt16638lv-p1rlv38126)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac361065-6b3c-4ac6-96d5-9b474eb3b80f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa4eed95-33b7-4827-8744-52d14149b386"}}}], "length": {"value": 0.00896862, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "950103b1-9ec6-4ba5-b24d-ea8b8cb59b5b", "name": "l(r:p1rdt16725lv-p1rlv38269)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bae9a352-584d-4cf0-9ebd-eb280b684e78"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cbb9976-253c-4863-899f-9218c4496688"}}}], "length": {"value": 0.00555125, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cf1cfe51-e7f4-4574-8253-da4972b54c2b", "name": "l(r:p1rdt7983-p1rdt8012)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bfb33cd-0cf1-455d-81e7-3d0472fa1b41"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e261b565-1f57-4cdc-bdd6-e045ee55d290"}}}], "length": {"value": 0.319354, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3b48fbf7-1282-4f8c-a6a8-8ae9f3b90bbf", "name": "l(r:p1rdt8012-p1rdt8034)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f83d22a-fa1e-4a4e-aab9-a9dea8ee06e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bfb33cd-0cf1-455d-81e7-3d0472fa1b41"}}}], "length": {"value": 0.0383866, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6243de73-7829-4099-a0ab-20bbf6c6ecea", "name": "l(r:p1rdt7954-p1rdt8034)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21e15d54-eab8-4204-9ed6-407fd8684700"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f83d22a-fa1e-4a4e-aab9-a9dea8ee06e5"}}}], "length": {"value": 0.256854, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9953443a-e512-47b5-b2da-2f9e9ddca7fc", "name": "l(r:p1rdt7954-p1rdt7973)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "016e4575-cd41-4993-be9b-5e5236a139ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21e15d54-eab8-4204-9ed6-407fd8684700"}}}], "length": {"value": 0.0497607, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a53ed3ef-f09a-4551-b82a-b6207878ef9a", "name": "l(r:p1rdt5172-p1rdt7973)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ea481f8-b9c7-4067-9bfb-4f7cdc5dee15"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "016e4575-cd41-4993-be9b-5e5236a139ae"}}}], "length": {"value": 0.289407, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "2c820636-d095-4272-9f89-d921819ff2af", "name": "l(r:p1rdt5155-p1rdt5172)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16712e10-4c7f-428b-917b-135ab3c2d4b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "afc636ed-f90c-4c48-822b-e86890d36f3b"}}}], "length": {"value": 0.0981862, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "cef0b639-e95b-4129-9dda-79e15491f213", "name": "l(r:p1rdt5155-p1rdt5172)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "afc636ed-f90c-4c48-822b-e86890d36f3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ea481f8-b9c7-4067-9bfb-4f7cdc5dee15"}}}], "length": {"value": 0.03419850000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "42c7cdb3-0fc1-4744-a4cb-bdb92a0ec9f0", "name": "l(r:p1rdt5155-p1rdt5201)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c289632-ba52-4b65-b6da-ac76b1477246"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16712e10-4c7f-428b-917b-135ab3c2d4b3"}}}], "length": {"value": 0.163704, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0e56a149-003c-40f3-90b4-32c09c9a86eb", "name": "l(r:p1rdt5159-p1rdt5201)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c289632-ba52-4b65-b6da-ac76b1477246"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee606236-08d7-4258-96c9-e9104f15b467"}}}], "length": {"value": 0.247666, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c41ff1f4-216c-4b99-9559-edc06bc0b68c", "name": "l(r:p1rdt5159-p1rdt5201)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee606236-08d7-4258-96c9-e9104f15b467"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90fb2270-4759-4779-80c1-7f93d66e1c53"}}}], "length": {"value": 0.0252803, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3b106144-995a-42f6-9105-373bd1547600", "name": "l(r:p1rdt5180-p1rdt5201)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86d3f96e-ffe2-459f-a2f1-b63d7bf138b8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c289632-ba52-4b65-b6da-ac76b1477246"}}}], "length": {"value": 0.165958, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "64b0948b-beb3-4234-9522-002661698319", "name": "l(r:p1rdt5923-p1rdt8346)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fec8a81-a151-4d8f-adc7-6d6d87d7759f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14b429c3-41da-4123-b661-40cbdfaf33e0"}}}], "length": {"value": 0.457454, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9be8e2a3-ed3b-4de7-8f25-6382fec041a4", "name": "l(r:p1rdt5923-p1rdt7988)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48e4b67a-0a47-48f0-b787-0a639db89caa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fec8a81-a151-4d8f-adc7-6d6d87d7759f"}}}], "length": {"value": 0.342603, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "cfb719d9-877c-4453-87ef-d4b5173d026f", "name": "l(r:p1rdt5180-p1rdt7988)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "893d2436-cd6c-40ad-90af-64ba1ac23f6e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48e4b67a-0a47-48f0-b787-0a639db89caa"}}}], "length": {"value": 0.958025, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4d35cd22-a1ac-48df-ae3c-d5a13715712d", "name": "l(r:p1rdt8447-p1rdt8456)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0089e5ea-d706-4a74-812f-654ae73eabcf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13b8cfc1-d8eb-4f47-b024-c1daacf3771d"}}}], "length": {"value": 0.30374700000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b83c03fc-f796-48d3-ad3b-2a3a22f58722", "name": "l(r:p1rdt8414-p1rdt8456)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34054ef8-8942-4471-ac14-43c6a37e5a16"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0089e5ea-d706-4a74-812f-654ae73eabcf"}}}], "length": {"value": 0.05634, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9e912236-8d08-4c01-94bf-41467552e199", "name": "l(r:p1rdt6272-p1rdt6274)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a53624b-8538-4cce-b588-c774875af31b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ac93b23-1041-486e-a16e-861082c92f35"}}}], "length": {"value": 0.108002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1c2a2bab-c82d-4a38-b710-8c8dfebf7049", "name": "l(r:p1rdt6272-p1rdt6274)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ac93b23-1041-486e-a16e-861082c92f35"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "034bda10-d48e-449c-9255-247cbf718683"}}}], "length": {"value": 0.00825442, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "923cb400-a742-4e52-948c-6c7d6cb7de45", "name": "l(r:p1rdt6271-p1rdt6274)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a75c5e2-2277-42b4-87d4-6eadff5c06f1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a53624b-8538-4cce-b588-c774875af31b"}}}], "length": {"value": 0.307488, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0a09a81b-a804-4407-b341-726e2c473678", "name": "l(r:p1rdt6270-p1rdt6271)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28954596-f060-4fa8-9f13-dfaa633bb739"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "898611f5-c343-4cca-8e5e-60cf0bfd796b"}}}], "length": {"value": 0.188113, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1369a137-ea26-496f-a49e-07fe1c36db1c"}}}}, {"uuid": "fe825001-39f1-4eda-af62-9c33a676d4b2", "name": "l(r:p1rdt6270-p1rdt6271)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "898611f5-c343-4cca-8e5e-60cf0bfd796b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b81bd5c2-96bb-445e-9eb8-d72360fd8a94"}}}], "length": {"value": 0.0296898, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "adfdca16-9dd2-4e84-828b-3cce8ceeead1", "name": "l(r:p1rdt7564-p1rdt7579)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76f6a27f-0e4f-48b8-9dbd-31c6ffc4ec75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa33ca9e-e16d-4c49-8a70-c6c30cf7b038"}}}], "length": {"value": 0.243188, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e28fa3c8-8478-435b-b24b-b2050db2515d", "name": "l(r:p1rdt7579-p1rdt7588)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76f6a27f-0e4f-48b8-9dbd-31c6ffc4ec75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f2dabc2-0b52-490c-b13a-32c268f6bd33"}}}], "length": {"value": 0.243808, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6c30a9e9-21aa-474e-8386-513a617c20c9", "name": "l(r:p1rdt7554-p1rdt7579)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f6de990-0988-4126-86ca-d1fd72c555fe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76f6a27f-0e4f-48b8-9dbd-31c6ffc4ec75"}}}], "length": {"value": 0.573836, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "558e228e-253b-4a6e-b393-6b01faeae27a", "name": "l(r:p1rdt7554-p1rdt7570)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2bdb2b51-0526-4995-bb5e-a2bd495488d4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f6de990-0988-4126-86ca-d1fd72c555fe"}}}], "length": {"value": 0.0647236, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d49f4c2c-8d0f-47c4-ae4b-a90f17979c57", "name": "l(r:p1rdt7559-p1rdt8015)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f239ef4e-83f0-4a2c-ada3-8e30cef38472"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff343735-753a-48ca-92b1-ea778c9e0b5c"}}}], "length": {"value": 0.10196200000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c0c2911d-ed07-4990-9abb-bc36add87fd0", "name": "l(r:p1rdt7559-p1rdt8015)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff343735-753a-48ca-92b1-ea778c9e0b5c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc543f54-740b-4a7f-b1c5-eb3783a8ade0"}}}], "length": {"value": 0.286466, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b9996b9e-d092-40f7-9d2d-9e261c16d724", "name": "l(r:p1rdt7559-p1rdt7570)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09814176-7891-4fe1-addf-b47aa106c40d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1dbec6c9-5c87-4f56-bd92-4a30d39ad094"}}}], "length": {"value": 0.14637200000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e4a51fb5-8e76-46ef-b920-7b77c5a4d877", "name": "l(r:p1rdt7559-p1rdt7570)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1dbec6c9-5c87-4f56-bd92-4a30d39ad094"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f239ef4e-83f0-4a2c-ada3-8e30cef38472"}}}], "length": {"value": 0.0849739, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1e1ff4ea-e8cd-413e-9ecd-a6b8b712c351", "name": "l(r:p1rdt7552-p1rdt7986)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db899c48-a801-4f83-b59d-e587ba80019d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "93a5388e-ffd7-403e-b6cf-26b7e81feed1"}}}], "length": {"value": 0.384727, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3c9d4cb9-43a5-4fef-a47c-22f1e23a19f3", "name": "l(r:p1rdt7551-p1rdt7552)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f0f3112-1395-48bf-88c1-8dd4b171478d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db899c48-a801-4f83-b59d-e587ba80019d"}}}], "length": {"value": 0.306203, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "887efa1d-3a26-4b29-9ee7-cd4d24b4122f", "name": "l(r:p1rdt7550-p1rdt7561)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc6bd64f-1ad3-4bd9-b590-7d4b673a94b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dead8520-e2f5-499b-9316-77780f9b1dfe"}}}], "length": {"value": 0.102524, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b5dbbf64-d586-472c-be8d-ec4d30c9538a", "name": "l(r:p1rdt8434-p1rdt8450)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f28de397-0db4-486a-8ce6-9f65c68703b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "184f95d4-cde1-4bf1-8a74-ebc7097cb10e"}}}], "length": {"value": 0.130615, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "310b27c0-aeca-4713-8dd9-75634008b0ca", "name": "l(r:p1rdt8434-p1rdt8440)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bbfe31b1-38ce-4ae4-9143-bf08c81617e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f28de397-0db4-486a-8ce6-9f65c68703b3"}}}], "length": {"value": 0.151253, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9d08c952-2d6b-430a-8ac4-049ad384831f", "name": "l(r:p1rdt8436-p1rdt8440)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bbfe31b1-38ce-4ae4-9143-bf08c81617e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "516ca275-0d8e-4a9a-ab59-89cb66b95d93"}}}], "length": {"value": 0.149159, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5ee7bf52-8efb-40b6-af57-c62fd8cd3acf", "name": "l(r:p1rdt8436-p1rdt8440)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "516ca275-0d8e-4a9a-ab59-89cb66b95d93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fcc42825-2690-4965-a99b-e78285a9b84e"}}}], "length": {"value": 0.105337, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "da33cb2a-7eaa-4cfc-9c3d-2a5cb32b1ee0", "name": "l(r:p1rdt8440-p1rdt8444)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bbfe31b1-38ce-4ae4-9143-bf08c81617e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f6e9b43-ceca-4a80-9569-696375a6ff5b"}}}], "length": {"value": 0.189207, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "81cb4004-68fb-40b6-a4c6-ce803572effe", "name": "l(r:p1rdt8440-p1rdt8444)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f6e9b43-ceca-4a80-9569-696375a6ff5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "685fbdbf-47af-4cc2-97ce-354dd04ce915"}}}], "length": {"value": 0.10008, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bc9ceca4-f632-4fd8-a6f7-84e549a2d515", "name": "l(r:p1rdt7555-p1rdt8440)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0075333-98fe-4ee8-bb64-a18119b817c0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bbfe31b1-38ce-4ae4-9143-bf08c81617e8"}}}], "length": {"value": 0.34151, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5f52d5ae-c7f7-405d-8cba-6f26dbf641c4", "name": "l(r:p1rdt7555-p1rdt7561)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc6bd64f-1ad3-4bd9-b590-7d4b673a94b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0075333-98fe-4ee8-bb64-a18119b817c0"}}}], "length": {"value": 0.0383631, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a5a9d7da-14d3-472d-9fbc-553a994c3f7b", "name": "l(r:p1rdt7551-p1rdt7561)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f0f3112-1395-48bf-88c1-8dd4b171478d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e068b84-fbff-4546-b708-ca91ffe92b69"}}}], "length": {"value": 0.124844, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0464cff4-421c-4922-a2f6-94dcd83b1534", "name": "l(r:p1rdt7551-p1rdt7561)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e068b84-fbff-4546-b708-ca91ffe92b69"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc6bd64f-1ad3-4bd9-b590-7d4b673a94b5"}}}], "length": {"value": 0.253169, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6d4670f0-7b81-49d7-8d20-f17d1629268c", "name": "l(r:p1rdt7551-p1rdt7574)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1d8c14d0-8247-4a44-98c1-4534aa9037a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f0f3112-1395-48bf-88c1-8dd4b171478d"}}}], "length": {"value": 0.382752, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "02a59a99-c259-48f2-92be-9d6473e77f82", "name": "l(r:p1rdt7553-p1rdt7572)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddf629eb-ea60-4fce-b731-7ebb33665829"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4307e78-304a-4175-8e81-9cb23d99f394"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0148f62b-4c0b-4711-8743-6575577331b4", "name": "l(r:p1rdt7553-p1rdt7574)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f00dd033-8e7c-43af-bd16-1de2954e07be"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7744d8d9-73a8-4274-9c91-5542620942f5"}}}], "length": {"value": 0.0977575, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "36947727-1aa5-4bcc-be37-bdb16a5a0db9", "name": "l(r:p1rdt7553-p1rdt7574)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7744d8d9-73a8-4274-9c91-5542620942f5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddf629eb-ea60-4fce-b731-7ebb33665829"}}}], "length": {"value": 0.0575736, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "14cc1fc7-59d4-4962-adf6-f9a219e7b2be", "name": "l(r:p1rdt5179-p1rdt6273)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9722136-480b-44cb-8b0e-0b3165712688"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d22f1247-b756-4498-8cf8-fef7d1e859ff"}}}], "length": {"value": 0.33969400000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ba35946f-4710-4036-87d9-e90e0fe76bc3", "name": "l(r:p1rdt8408-p1rdt8458)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28af960e-6f27-483a-8029-0c5f1641f51d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "433162b1-2a9b-4187-ba28-ec57503d76f6"}}}], "length": {"value": 0.0888364, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "71ca0f35-18a0-4a56-a50e-ad4f4c9b6f17", "name": "l(r:p1rdt8408-p1rdt8439)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07f340ca-58c2-4331-8265-a39a45c87b75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3430524c-820d-4f17-ba1b-377aeef4bbcd"}}}], "length": {"value": 0.217599, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "21683217-7a15-47db-8cb9-e443f8569fee", "name": "l(r:p1rdt8408-p1rdt8439)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3430524c-820d-4f17-ba1b-377aeef4bbcd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28af960e-6f27-483a-8029-0c5f1641f51d"}}}], "length": {"value": 0.0862144, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3871706d-53bc-4f3c-887c-1b304b0b5bc9", "name": "l(r:p1rdt6278-p1rdt8439)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19d5304c-574f-4646-8095-d2dcbbea86e7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07f340ca-58c2-4331-8265-a39a45c87b75"}}}], "length": {"value": 0.21709300000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6e3a4316-b83a-4df8-a57c-681507b74e08", "name": "l(r:p1rdt8405-p1rdt8445)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8c69243-872f-4e25-9d03-82692bbf8779"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e3ecdca-4b27-4a9d-8599-637924e86602"}}}], "length": {"value": 0.173131, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "99bc096c-88d2-40dc-84bb-74b6f5ee26b3", "name": "l(r:p1rdt8405-p1rdt8445)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e3ecdca-4b27-4a9d-8599-637924e86602"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc0ee90f-1f9e-435e-bac4-86a4688c48fc"}}}], "length": {"value": 0.152596, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "98f7d539-1e7f-40ee-8dda-dcda64bf53e9", "name": "l(r:p1rdt6500-p1rdt6519)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf648a0d-3262-4150-892b-55c3b117050a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5789c3b2-eb91-4e4c-85e8-24f5893e1a2c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1369a137-ea26-496f-a49e-07fe1c36db1c"}}}}, {"uuid": "daedf677-1099-4aa3-b007-b47edc2916ce", "name": "l(r:p1rdt6505-p1rdt6508)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0824c21-244b-4d4e-85d6-238ac4908b5a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb1c1e50-902d-443d-8c9a-b728d2f6b6f1"}}}], "length": {"value": 0.10179900000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d8c829f8-5194-4cb1-81b5-c3a846ffa9d2", "name": "l(r:p1rdt6510-p1rdt6523)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66b7b2e9-7658-4de0-8197-3829c6179353"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "848c04de-e4d5-4520-9dce-0073776c2ae4"}}}], "length": {"value": 0.167854, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "946d1cc9-2f20-4a54-9480-38deb15660e0", "name": "l(r:p1rdt5730-p1rdt9479)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e07d8bc1-2f8a-4067-a2a7-b903dd042ce3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5897bb2-1f72-4aeb-9090-74e2411b5786"}}}], "length": {"value": 0.30509600000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b0df22f1-d622-429d-8f86-7353e33fde28", "name": "l(r:p1rdt5840-p1rdt9479)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7f9286b-4209-402a-a365-1d27da4efb75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35722d90-049e-4c67-9654-acce0572e6c2"}}}], "length": {"value": 0.269952, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "10ffe1dd-0ef5-4c2b-971d-7dd0c7f0540a", "name": "l(r:p1rdt9298-p1rdt9302)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61ba1001-8b9d-481c-b205-45c6e0beadc1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4a41fe9-62ce-45ba-abcd-086ba429baa0"}}}], "length": {"value": 0.0784931, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b6cf13dc-5432-46f6-8ce7-4dcd6142e06d", "name": "l(r:p1rdt9298-p1rdt9310)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3035d22c-c39f-4f07-9fe9-29888b16057d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61ba1001-8b9d-481c-b205-45c6e0beadc1"}}}], "length": {"value": 0.189404, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ddc2c0a9-cf9d-4540-b621-99c53b060d78", "name": "l(r:p1rdt9310-p1rdt9316)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "644c5887-31f1-436c-bbf6-dae5a70743a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3035d22c-c39f-4f07-9fe9-29888b16057d"}}}], "length": {"value": 0.277772, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4617ca55-9b70-443a-912a-2c0b71d2435e", "name": "l(r:p1rdt9312-p1rdt9316)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "644c5887-31f1-436c-bbf6-dae5a70743a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8721684-5439-482c-b8e5-be330d3cf745"}}}], "length": {"value": 0.433834, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c9872dd4-7084-47d2-9b48-0a683d1d5018", "name": "l(r:p1rdt9311-p1rdt9316)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7011f1dc-1e7d-4961-9a23-620b7f5737af"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "644c5887-31f1-436c-bbf6-dae5a70743a2"}}}], "length": {"value": 0.0277071, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e40bd2c2-6249-4777-9efb-9cafe9e9e47b", "name": "l(r:p1rdt6518-p1rdt9311)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95d939ff-e20d-42b3-bb88-f1975f9fa0aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7011f1dc-1e7d-4961-9a23-620b7f5737af"}}}], "length": {"value": 0.103982, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4149df31-d706-455a-9122-9362e3df9b22", "name": "l(r:p1rdt5729-p1rdt5731)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "77d2122b-cbb7-4844-bbb2-55e939431e50"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52f308f4-35db-49ec-a599-f8380489f952"}}}], "length": {"value": 0.353232, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7b3b465f-dd27-42e7-804a-f97d4617ee2f", "name": "l(r:p1rdt5729-p1rdt5731)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52f308f4-35db-49ec-a599-f8380489f952"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95cd61cf-f1cb-4af2-9d3b-e42978642003"}}}], "length": {"value": 0.0107406, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "709aa023-da9c-4e74-80c6-9ac1241821a6", "name": "l(r:p1rdt5728-p1rdt5729)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b55c58cf-153e-4aa3-b099-8a1db05a6ae5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "77d2122b-cbb7-4844-bbb2-55e939431e50"}}}], "length": {"value": 0.125902, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f75bfbb4-dd53-4f91-99e8-d7364ccf82f6", "name": "l(r:p1rdt5728-p1rdt6537)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66ef2ffb-e67d-47eb-ae59-194c538ab861"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b55c58cf-153e-4aa3-b099-8a1db05a6ae5"}}}], "length": {"value": 0.543863, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b25e1279-aaff-4785-8b93-94d78d7a2bed", "name": "l(r:p1rdt6502-p1rdt9468)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b5695dd-714e-4de1-a63a-f142ff0460e1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e6348d4-7fcb-4546-af84-8ece75b6332f"}}}], "length": {"value": 0.434441, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7d206cf2-ecd2-4567-8615-e996c54cd96c", "name": "l(r:p1rdt6501-p1rdt9468)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddfa01c0-4d12-4f96-ab50-0082ef9914a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e4fd2ed-daa1-4a22-936f-8d51ee928d99"}}}], "length": {"value": 0.099806, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bd9d8818-aa67-4354-b9a9-81d0a90330c9", "name": "l(r:p1rdt6509-p1rdt6514)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42f09ae1-037a-4565-9cd2-0187c45b7866"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0737f6ec-0d5d-4cff-b4b7-9910c7076984"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ca790b78-4e94-4ea4-8d32-da938c5aef92", "name": "l(r:p1rdt6498-p1rdt6516)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60b93cd6-c9fc-46ef-8b37-6b14d0773df6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5c5466f-b7e4-4844-967b-9e8b11c68b44"}}}], "length": {"value": 0.0377529, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "34f48699-c9c2-4f8d-8e66-5822d807e169", "name": "l(r:p1rdt7298-p1rdt7313)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1f6ad7d-f7ea-4b94-956c-ec4a3b2028d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b658bf21-450c-4e6b-9dec-c5023a05fd19"}}}], "length": {"value": 0.0390759, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5d3b1a39-3b9f-43d5-a263-b7e274732cb7", "name": "l(r:p1rdt7036-p1rdt7091)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28d17238-8db8-41da-960c-317183423576"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "770cf0ab-50f1-489b-b2ea-d23ba186d10b"}}}], "length": {"value": 0.10505000000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "85f2d27c-47d3-49d1-9a52-3f41ebb66c72", "name": "l(r:p1rdt7036-p1rdt7091)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "770cf0ab-50f1-489b-b2ea-d23ba186d10b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52068090-b613-46d7-a31f-ad3ca26382d5"}}}], "length": {"value": 0.042633, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "81dd9e15-fe70-4d77-bf53-8ac6b6c4d15b", "name": "l(r:p1rdt7620-p1rdt7627)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97be7ac3-a710-4de8-a666-276813582cd6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5bddd75e-1974-41ee-ab51-625c7485a573"}}}], "length": {"value": 0.0237579, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6bdc087e-f95c-4fbe-bfc6-4a0c6270342d", "name": "l(r:p1rdt7311-p1rdt7620)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3a4dfb4-e1b3-43b9-ae42-b0cec47ff4ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97be7ac3-a710-4de8-a666-276813582cd6"}}}], "length": {"value": 0.142725, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ee2d29a7-a257-4805-9145-9257ecfda11e", "name": "l(r:p1rdt7311-p1rdt9473)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3a4dfb4-e1b3-43b9-ae42-b0cec47ff4ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4d8bafa-711d-4fd7-8374-7eeaeb43edcd"}}}], "length": {"value": 0.0811399, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3efc6b05-eb72-4c79-b237-e882fc3d458c", "name": "l(r:p1rdt7306-p1rdt7311)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "607c7275-da9a-4620-b019-59a66e98c2e6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3a4dfb4-e1b3-43b9-ae42-b0cec47ff4ad"}}}], "length": {"value": 0.0813524, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1ddc01b0-2a75-4050-b3a0-41dcad8ecd63", "name": "l(r:p1rdt7306-p1rdt7626)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "607c7275-da9a-4620-b019-59a66e98c2e6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56d67e3e-46af-4e2c-86a8-191d97b0ce8a"}}}], "length": {"value": 0.166342, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ac22d4a7-8ef7-47a3-8567-dbafa8b1ce03", "name": "l(r:p1rdt7302-p1rdt7306)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a65c4d3-2fc6-48c8-b944-68c4229db3dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "607c7275-da9a-4620-b019-59a66e98c2e6"}}}], "length": {"value": 0.183526, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e036c895-092e-4d78-ae61-8e6f09fca24f", "name": "l(r:p1rdt7302-p1rdt7617)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01c9d31d-c3bb-4950-9bbd-00377c252ddc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a65c4d3-2fc6-48c8-b944-68c4229db3dd"}}}], "length": {"value": 0.047802300000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "70140404-3f92-4e1f-a77d-b86b6a9a60d5", "name": "l(r:p1rdt7617-p1rdt7625)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a11cf3d9-90bb-4de8-b637-6ec9128525ec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01c9d31d-c3bb-4950-9bbd-00377c252ddc"}}}], "length": {"value": 0.0218023, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1f189dee-08e4-4079-bab5-e8a21d66de1f", "name": "l(r:p1rdt7616-p1rdt7630)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "723e2b5c-414c-4f3d-ba23-d2df4bc63e75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7167a2e-9e83-441e-a15b-0256848c3f6d"}}}], "length": {"value": 0.140205, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "fa7dc0a1-b720-42aa-93aa-5e53edf78be1", "name": "l(r:p1rdt7621-p1rdt7630)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa48cf27-3b07-4460-ad9c-8d9862238645"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "723e2b5c-414c-4f3d-ba23-d2df4bc63e75"}}}], "length": {"value": 0.0539367, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c2ab22f8-e100-4ef0-89b3-a41bcc8ad74f", "name": "l(r:p1rdt7621-p1rdt7625)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53df7b6e-bd8c-43f2-860d-8869aec5d079"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa48cf27-3b07-4460-ad9c-8d9862238645"}}}], "length": {"value": 0.18848800000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "771f897b-1f10-40db-b3d7-4066cc1d7638", "name": "l(r:p1rdt7054-p1rdt7090)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08d3a02a-555d-4ad1-9b13-d413b7a16eef"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3cf406b-69e6-4aee-a6fc-272dad7693a4"}}}], "length": {"value": 0.0578677, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "31498136-0f28-4bd8-98f5-9acb29e9649c", "name": "l(r:p1rdt7069-p1rdt7090)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aae22557-7d34-401d-82c9-2d2710ff2915"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08d3a02a-555d-4ad1-9b13-d413b7a16eef"}}}], "length": {"value": 0.128791, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "cdee7d08-5c71-4bf8-a182-b3c06db81686", "name": "l(r:p1rdt7069-p1rdt7087)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f614382d-3883-4f6b-b1f6-c8e83d84ee22"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aae22557-7d34-401d-82c9-2d2710ff2915"}}}], "length": {"value": 0.09476340000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d3bca9dc-c799-419f-9d47-eeac6c2ed7df", "name": "l(r:p1rdt7075-p1rdt7087)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8cebb186-4d9e-4d2c-b0d9-100056d34942"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f614382d-3883-4f6b-b1f6-c8e83d84ee22"}}}], "length": {"value": 0.198314, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1ee5dd7f-8852-4cb7-a544-f046413b4410", "name": "l(r:p1rdt7075-p1rdt7080)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "662e2a1c-9a54-4ac3-b478-98e3a478349d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8cebb186-4d9e-4d2c-b0d9-100056d34942"}}}], "length": {"value": 0.127901, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "389f514c-fe23-4cce-aa69-67e8571eb690", "name": "l(r:p1rdt7080-p1rdt7619)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "161d6f3b-8bd9-4fa8-9442-c6ff008e8d3d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "662e2a1c-9a54-4ac3-b478-98e3a478349d"}}}], "length": {"value": 0.059386400000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4cf5b365-3f96-468a-aeb9-3dcdf312110b", "name": "l(r:p1rdt7615-p1rdt7619)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "161d6f3b-8bd9-4fa8-9442-c6ff008e8d3d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "105df8ff-ec38-4cd6-b557-c318b4023bd0"}}}], "length": {"value": 0.217966, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3231a082-6540-4f71-a015-260c8614cb63", "name": "l(r:p1rdt7619-p1rdt7631)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9e53141-a773-4127-9558-3887070a8f36"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "161d6f3b-8bd9-4fa8-9442-c6ff008e8d3d"}}}], "length": {"value": 0.0570511, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4cc17ad4-3478-4c0c-8565-3dcaeb133743", "name": "l(r:p1rdt7625-p1rdt7631)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "460f5de9-8d4f-468a-b67a-b3b05354a9ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9e53141-a773-4127-9558-3887070a8f36"}}}], "length": {"value": 0.204577, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f8db6b2e-8307-43f8-a986-8c951fc06e7c", "name": "l(r:p1rdt6515-p1rdt6535)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fec078c2-a5d8-4317-a8ac-bc25772f6358"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5a05d0e-8cf2-4ab8-bdfd-24b8cd12ad67"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1369a137-ea26-496f-a49e-07fe1c36db1c"}}}}, {"uuid": "fcee0ed8-6baf-4eef-b433-a2ba9085968a", "name": "l(r:p1rdt6515-p1rdt6536)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04c1e05a-9cbb-4e53-9412-1cffd3976bed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5aa6899b-19a2-41e6-b445-f9fe2536c8d9"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1369a137-ea26-496f-a49e-07fe1c36db1c"}}}}, {"uuid": "16950521-fdd9-46ba-b9eb-d9f5b812710e", "name": "l(r:p1rdt8901-p1rdt8902)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d21061fa-1011-44f7-8a20-26fcf0550f52"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f23ab51c-56f3-4421-b66e-7cdcf109787d"}}}], "length": {"value": 0.309301, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b24e98ec-fd06-44e5-becf-6da45152feab", "name": "l(r:p1rdt7301-p1rdt9377)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61972a50-ce24-4ec1-8535-402665b55a55"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84200441-4c26-4966-a4b7-6b91fb43f02e"}}}], "length": {"value": 0.355831, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "33c4c723-7618-4494-9cf7-a8a01746a442", "name": "l(r:p1rdt8902-p1rdt9377)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43c862de-b014-4b24-8b34-54dae6edcf5a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32e86968-974e-4bcc-b562-1d4209771cf0"}}}], "length": {"value": 0.172034, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "04c8a47f-0b2d-4b5d-af7e-6361e20360cb", "name": "l(r:p1rdt8490-p1rdt9463)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37c41a4b-e439-42a1-b9a7-0582c528f0e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "271ab023-4425-40d8-8080-2481c71309b5"}}}], "length": {"value": 0.21351000000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "83e505b0-a9d8-4e85-ba9c-50cf7624af58", "name": "l(r:p1rdt8490-p1rdt8492)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "307d9c6d-d5ee-4490-95d3-5a9b1d171e54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37c41a4b-e439-42a1-b9a7-0582c528f0e5"}}}], "length": {"value": 0.0991871, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e2567550-8f85-4d77-96b7-a3ef3a0089e0", "name": "l(r:p1rdt7599-p1rdt8492)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "605c34bc-3f7c-4eb7-8df0-fcd00d261921"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3833996b-287c-4a13-9e7c-6834047f3691"}}}], "length": {"value": 1.29606, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5a80d1ee-2c0b-4cff-80ee-f9a438a10bca", "name": "l(r:p1rdt7599-p1rdt8492)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3833996b-287c-4a13-9e7c-6834047f3691"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "307d9c6d-d5ee-4490-95d3-5a9b1d171e54"}}}], "length": {"value": 2.04702, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7d48cc0e-c882-49ae-be92-fe816aa16373", "name": "l(r:p1rdt6226-p1rdt9333)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f6d3fab-3b83-40c9-85c4-cfeddd0d317a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76f24b35-1b82-4760-9817-80c166073f37"}}}], "length": {"value": 0.0994771, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6f3ebb5c-96d5-480e-8403-d35921fdeaae", "name": "l(r:p1rdt6226-p1rdt9333)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76f24b35-1b82-4760-9817-80c166073f37"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d81fc6d7-3400-41d4-91d7-b350d7def98d"}}}], "length": {"value": 0.117787, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5b73908d-2f28-48e9-a7e7-aa024cdccfc5", "name": "l(r:p1rdt5650-p1rdt5662)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36c3c493-ff68-4bb8-a3f4-043c5f847bd3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8f1c67e-9e29-45a3-a2a3-c2f3493a6898"}}}], "length": {"value": 0.373528, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bf809203-3662-4e57-8041-984c2164057f", "name": "l(r:p1rdt5658-p1rdt5663)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81f0e00e-bc49-448a-8e69-0569ed6a8c1a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67d07fb-aec5-4120-8254-32bfcd91e378"}}}], "length": {"value": 0.167002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "83ab7e51-98a6-4e95-b5fa-6c9c2095e331", "name": "l(r:p1rdt5658-p1rdt5663)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67d07fb-aec5-4120-8254-32bfcd91e378"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7356d982-36fd-46cb-9300-8889502e8dc8"}}}], "length": {"value": 0.0344971, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d376dca1-f218-4215-bdc9-4841f949ab27", "name": "l(r:p1rdt7046-p1rdt7067)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b470fa62-70d4-4cc5-8f7e-b9cda37481e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9bb8596a-bcb2-4282-bf1b-9939a9af87d9"}}}], "length": {"value": 0.207649, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "394c4f8d-a10c-4cc7-8d1b-605bc435f8b5", "name": "l(r:p1rdt7038-p1rdt7067)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb3a9847-70d0-4004-95ef-63884c6c1cdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b470fa62-70d4-4cc5-8f7e-b9cda37481e0"}}}], "length": {"value": 0.160885, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5af024a4-176d-4d88-92aa-1cce7304ee2e", "name": "l(r:p1rdt7038-p1rdt7070)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac6e8ccf-75ec-42e0-a3cb-9ab86e2731a4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9cb2d8d-1991-463c-9e6b-88f5624f28c3"}}}], "length": {"value": 0.0923408, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "26068bfb-36ee-4ac3-959b-e22ca0508ad2", "name": "l(r:p1rdt7038-p1rdt7070)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9cb2d8d-1991-463c-9e6b-88f5624f28c3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb3a9847-70d0-4004-95ef-63884c6c1cdc"}}}], "length": {"value": 0.238971, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a443312f-ca47-446d-960f-3de76a23b1f2", "name": "l(r:p1rdt9381-p1rdt9396)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a597011-5e60-46fe-90d6-85728ff0ffa3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5791345-57dc-4f54-ab54-ea63e6a54ee0"}}}], "length": {"value": 0.139587, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bcb59ecd-71f2-4a91-9918-2f6cfe394c47", "name": "l(r:p1rdt7088-p1rdt9396)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac70c13b-5f4f-45f3-880a-b4b476ea552a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a597011-5e60-46fe-90d6-85728ff0ffa3"}}}], "length": {"value": 0.16851400000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f066d9af-3a31-4e4e-9df6-3876ea0e5186", "name": "l(r:p1rdt7088-p1rdt7089)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31cd4834-477f-4060-8efd-0504c8e8eaa9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac70c13b-5f4f-45f3-880a-b4b476ea552a"}}}], "length": {"value": 0.07985440000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "08efaac7-6d95-4425-a194-e9fd5edb3d32", "name": "l(r:p1rdt7061-p1rdt7089)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75947ffd-3765-443b-bef8-b6af746ef624"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "324f5d62-9feb-4fe4-bc1b-3dcf01898148"}}}], "length": {"value": 0.135079, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1a1b0973-d4c6-47d7-8d97-e21a08b578a2", "name": "l(r:p1rdt7061-p1rdt7089)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "324f5d62-9feb-4fe4-bc1b-3dcf01898148"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31cd4834-477f-4060-8efd-0504c8e8eaa9"}}}], "length": {"value": 0.18246, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "552b8434-b608-4927-a5b9-ea068ccdc34d", "name": "l(r:p1rdt7061-p1rdt7070)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac6e8ccf-75ec-42e0-a3cb-9ab86e2731a4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84578de8-d5de-41fe-b637-42425e97b7db"}}}], "length": {"value": 0.128507, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3459416c-f085-4e60-9593-ce3b3585f76c", "name": "l(r:p1rdt7061-p1rdt7070)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84578de8-d5de-41fe-b637-42425e97b7db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75947ffd-3765-443b-bef8-b6af746ef624"}}}], "length": {"value": 0.322501, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a1c26b2c-7b4a-4027-88a6-1cbb94147d65", "name": "l(r:p1rdt5658-p1rdt7070)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02407b52-58c3-403c-9b5b-38695f435476"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac6e8ccf-75ec-42e0-a3cb-9ab86e2731a4"}}}], "length": {"value": 0.61978, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4c909e74-bd70-48ae-b4b9-fa6c0f49c742", "name": "l(r:p1rdt5017-p1rdt5200)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0843e99-e917-473c-bec7-ee0c3ddec601"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "799ab435-c0a4-4515-8125-e8ca2fb7632d"}}}], "length": {"value": 0.234989, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3904e139-a874-4ec4-b65c-f1113096a4b4", "name": "l(r:p1rdt7576-p1rdt8422)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b28595b-dcbe-4d1b-92c4-94acf370bb1f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ce65512-7d5f-4514-b55c-1775e80dd94d"}}}], "length": {"value": 0.0564986, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "91556012-ddc5-4cf8-828a-a6303f5cb1bd", "name": "l(r:p1rdt7576-p1rdt8151)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a31fa2-4df8-418a-a215-d0d450ced9a3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df71ab4b-258c-4812-9537-6d425bacb468"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "96c8992e-ab08-485e-8757-96b0e71fedc8", "name": "l(r:p1rdt7576-p1rdt8151)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df71ab4b-258c-4812-9537-6d425bacb468"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c951cf67-3297-407f-805c-55d9c03fb519"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "75782f97-8d8e-4957-97f0-8e2dabe321d9", "name": "l(r:p1rdt7576-p1rdt8151)_s2", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c951cf67-3297-407f-805c-55d9c03fb519"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b28595b-dcbe-4d1b-92c4-94acf370bb1f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7c6ac7b6-d8d7-455b-817c-4553072e5c9a", "name": "l(r:p1rdt8149-p1rdt8155)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1613a53e-5194-4d26-b83b-475d9f02a32c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b706c56-20f1-49ed-9cbe-0ec1491b83e0"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "40a5a234-9d35-48aa-8436-976911dc216f", "name": "l(r:p1rdt5153-p1rdt8441)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b423745-cc70-4c3a-adb0-f648170b4ab1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dac2cb8c-428b-49c4-8368-35608c050390"}}}], "length": {"value": 0.190536, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "cf871f54-cd17-4e6e-b56a-680cb64f1680", "name": "l(r:p1rdt5153-p1rdt8441)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dac2cb8c-428b-49c4-8368-35608c050390"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dff898c1-a386-4219-9e8d-2d08b49f9098"}}}], "length": {"value": 0.26071, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b28e3e27-9c0e-4a4e-89c9-565fdc854f99", "name": "l(r:p1rdt5153-p1rdt8441)_s2", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dff898c1-a386-4219-9e8d-2d08b49f9098"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb8dae66-287a-4b8a-9cda-6ae02cb8f8a9"}}}], "length": {"value": 0.128532, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "21a471ec-3f91-4bac-9f9c-2f63f39e7608", "name": "l(r:p1rdt8150-p1rdt8441)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78081763-07d2-4989-b492-e1c5178c4097"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83b76782-be09-4733-a35c-6f3f26059a4d"}}}], "length": {"value": 0.16747, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "59606c40-3050-4e1f-84d7-b3adeab006eb", "name": "l(r:p1rdt8150-p1rdt8441)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83b76782-be09-4733-a35c-6f3f26059a4d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b423745-cc70-4c3a-adb0-f648170b4ab1"}}}], "length": {"value": 0.585344, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9390eaa1-85ed-427d-b557-87485f68297d", "name": "l(r:p1rdt8150-p1rdt8442)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78081763-07d2-4989-b492-e1c5178c4097"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2ef098d-d7e6-4530-a5cc-b6472ec9ffdc"}}}], "length": {"value": 0.219381, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ae6dfad9-4b8b-4567-beea-e08350b422f2", "name": "l(r:p1rdt8150-p1rdt8442)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2ef098d-d7e6-4530-a5cc-b6472ec9ffdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6700763-e6dc-4626-ac2b-22985f0043be"}}}], "length": {"value": 0.29839800000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9914a6ee-984e-4689-83bb-a541dd092fc7", "name": "l(r:p1rdt8150-p1rdt8155)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1613a53e-5194-4d26-b83b-475d9f02a32c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b7280d1f-5ff9-45ee-9949-ecc70509a2a1"}}}], "length": {"value": 0.0723619, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "deed0a14-e67a-4500-9626-be034c9a20fa", "name": "l(r:p1rdt8150-p1rdt8155)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b7280d1f-5ff9-45ee-9949-ecc70509a2a1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78081763-07d2-4989-b492-e1c5178c4097"}}}], "length": {"value": 0.0446835, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8f14f92d-f5a4-4941-a518-79a7131e3bdd", "name": "l(r:p1rdt8155-p1rdt8157)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1613a53e-5194-4d26-b83b-475d9f02a32c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a30e197-897f-4516-b4e5-f70081e6f8c7"}}}], "length": {"value": 0.11694, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c9ae81de-99a7-45de-8eae-0dc8d72eb86c", "name": "l(r:p1rdt8151-p1rdt8155)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0a6628e-afc1-4daf-8a29-7626ac2aa5dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1613a53e-5194-4d26-b83b-475d9f02a32c"}}}], "length": {"value": 0.09203890000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "17a9aea4-714b-4a9e-bc93-6d59c828ea03", "name": "l(r:p1rdt5481-p1rdt5483)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f903015c-95a7-4d6e-b2a5-e9705c050c6e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d29d8b74-a24d-4474-9752-c1ffa1aa7f7c"}}}], "length": {"value": 0.218893, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bc927f95-acf8-4e59-9de3-a63c5a83649d", "name": "l(r:p1rdt5480-p1rdt5483)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2568f11c-8a37-4a55-8bce-9f0d56ac386a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f903015c-95a7-4d6e-b2a5-e9705c050c6e"}}}], "length": {"value": 0.0194577, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "dcc2039e-e644-4d69-b245-4b2970b5781d", "name": "l(r:p1rdt5477-p1rdt5480)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7d7f462-1ab5-4fd8-baaa-7e576eead5c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2568f11c-8a37-4a55-8bce-9f0d56ac386a"}}}], "length": {"value": 0.05838600000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "16f55ad7-24d9-4ec0-8729-a3f0c865164a", "name": "l(r:p1rdt5477-p1rdt7201)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7d7f462-1ab5-4fd8-baaa-7e576eead5c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df1d5615-4a0b-4041-8940-f13de9f7036a"}}}], "length": {"value": 0.101327, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "cb4e31da-15dd-4846-95b9-04865a0bcc59", "name": "l(r:p1rdt5477-p1rdt7201)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df1d5615-4a0b-4041-8940-f13de9f7036a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f64ed4a2-6afb-447c-8c6b-15935e050a6d"}}}], "length": {"value": 0.0635197, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1e1f4f6c-9c9c-4c7c-afa2-84cde862974f", "name": "l(r:p1rdt5472-p1rdt5477)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a8c3f7f-b9be-4c5e-b6f0-8f2fc18935fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "595463a5-2019-4c94-b72d-c824c2aef347"}}}], "length": {"value": 0.182509, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "436ac0bd-b246-48ce-94e1-7b1b0df0c7c7", "name": "l(r:p1rdt5472-p1rdt5477)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "595463a5-2019-4c94-b72d-c824c2aef347"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7d7f462-1ab5-4fd8-baaa-7e576eead5c7"}}}], "length": {"value": 0.00190877, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c20d723c-25d6-4888-b6f4-97cc3e392f79", "name": "l(r:p1rdt5472-p1rdt5476)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d69527e6-70b6-43e2-8b9e-7c8570ad5ddf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a8c3f7f-b9be-4c5e-b6f0-8f2fc18935fa"}}}], "length": {"value": 0.464713, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ac8991d3-6d78-4983-999e-61a1df7121c2", "name": "l(r:p1rdt7704-p1rdt9266)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02ea9067-6a2a-48b6-b5f1-10992b9fbd77"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f633393e-4d67-4646-838b-14f25641b426"}}}], "length": {"value": 0.327122, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "63d17b30-daf0-4906-8098-2e394c28e221", "name": "l(r:p1rdt7704-p1rdt9266)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f633393e-4d67-4646-838b-14f25641b426"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fbb2bd0-d109-4248-85f3-266fe479677f"}}}], "length": {"value": 0.119759, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "91bc4b46-c695-480b-858f-4fb349c9f026", "name": "l(r:p1rdt7704-p1rdt7712)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4462b9c6-748f-48e9-9ff9-7f20a06cf456"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02ea9067-6a2a-48b6-b5f1-10992b9fbd77"}}}], "length": {"value": 0.290826, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "74871719-24e2-4446-a5c1-6607bc9b6bd2", "name": "l(r:p1rdt7712-p1rdt7718)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4462b9c6-748f-48e9-9ff9-7f20a06cf456"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "048e2bab-67f2-4975-81a1-bbc9f2f9cd88"}}}], "length": {"value": 0.315016, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8fb5ae90-d852-4217-8ad8-7e35ff1771ef", "name": "l(r:p1rdt7701-p1rdt7712)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "74968ebc-53c5-4fc6-8172-3ffa9dea7683"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4462b9c6-748f-48e9-9ff9-7f20a06cf456"}}}], "length": {"value": 0.0526994, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "764fe5e3-4f60-49ac-b40e-80e11eef2a63", "name": "l(r:p1rdt7699-p1rdt7701)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec849ee4-3d69-46a9-9a2a-242a3943e46c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "74968ebc-53c5-4fc6-8172-3ffa9dea7683"}}}], "length": {"value": 0.0894152, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "948e03e5-6f8e-4e2a-b745-53bc7ae9fb10", "name": "l(r:p1rdt5485-p1rdt7699)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cfb3a23-3a93-4d89-8b70-e4730ebbce1a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "890cd47a-994b-4dca-8d59-25164f04c927"}}}], "length": {"value": 0.126204, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "432a59ab-ea4f-45fb-b79f-173e74a857ab", "name": "l(r:p1rdt5485-p1rdt7699)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "890cd47a-994b-4dca-8d59-25164f04c927"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec849ee4-3d69-46a9-9a2a-242a3943e46c"}}}], "length": {"value": 0.179947, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e51e0264-f754-45e2-a1b3-933e30c3cd56", "name": "l(r:p1rdt5475-p1rdt5485)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b9e57e0-6dc8-4831-ac7d-36f8608b7a8d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cfb3a23-3a93-4d89-8b70-e4730ebbce1a"}}}], "length": {"value": 0.0575139, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ecfbc31a-21c6-47a5-a744-7345eb49ee1e", "name": "l(r:p1rdt5475-p1rdt5476)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae343ca3-3337-4528-b117-38a51e6d023f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b9e57e0-6dc8-4831-ac7d-36f8608b7a8d"}}}], "length": {"value": 0.453804, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0dfee531-83f3-4357-8062-4451c875f683", "name": "l(r:p1rdt5476-p1rdt5478)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c977e6c-43f0-4d7e-b19f-82f0de97dab2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a97491e-2c98-4584-9b74-5593f17faeda"}}}], "length": {"value": 0.3849, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "63f4017a-0e53-4030-9f03-15546872260d", "name": "l(r:p1rdt6848-p1rdt9264)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96399e51-1243-4e7f-ae3a-5e2c67123aae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b764d22-debb-4d88-8221-ff79307e609f"}}}], "length": {"value": 0.24693, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "62ef9b36-dcd1-4bc0-907a-675b87e52164", "name": "l(r:p1rdt6848-p1rdt9264)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b764d22-debb-4d88-8221-ff79307e609f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bdf3994-bb0c-44f4-b1ea-ab29e73bd39c"}}}], "length": {"value": 0.116892, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3b953a51-c8a1-4a38-8773-f8a7016dfcbf", "name": "l(r:p1rdt6847-p1rdt6848)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e92b102-eaee-41cc-a2fc-c6c4b3bfb58b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96399e51-1243-4e7f-ae3a-5e2c67123aae"}}}], "length": {"value": 0.92611, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "480f3768-51e4-48e1-a449-a533eb206658", "name": "l(r:p1rdt6847-p1rdt7624)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be9350ab-7ad2-4a89-a374-94bf69588d7f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e92b102-eaee-41cc-a2fc-c6c4b3bfb58b"}}}], "length": {"value": 0.622643, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "2792a58e-fa63-427d-950f-9719c7fa27ea", "name": "l(r:p1rdt6348-p1rdt6350)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d6c5b78-35c4-475a-8837-776dea236c95"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c935f1c0-e36c-407d-a2e8-4181c4b0733e"}}}], "length": {"value": 0.150337, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bdb40655-4f94-4583-af63-540676cc787b", "name": "l(r:p1rdt6345-p1rdt6348)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40280da5-767c-4610-b6a8-ff411e1c33e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d6c5b78-35c4-475a-8837-776dea236c95"}}}], "length": {"value": 0.368527, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "50411b97-2ca0-4fd4-a03d-cd1d5a15d841", "name": "l(r:p1rdt6345-p1rdt6356)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1bdfc1ac-98a4-43dd-bb2c-837d0a2c15f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40280da5-767c-4610-b6a8-ff411e1c33e8"}}}], "length": {"value": 0.463971, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9944e15d-1d1f-4de2-b2d7-73810d8a552e", "name": "l(r:p1rdt6353-p1rdt6356)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1bdfc1ac-98a4-43dd-bb2c-837d0a2c15f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e51e0d9-24b6-40ac-859a-51ea74c93e76"}}}], "length": {"value": 0.407215, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "73284547-7d9c-4518-b0b1-abc15099090f", "name": "l(r:p1rdt6354-p1rdt6356)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1bdfc1ac-98a4-43dd-bb2c-837d0a2c15f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2040b1a2-85bc-405a-9dab-138561b5e3ac"}}}], "length": {"value": 0.108189, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6396a12f-73d3-4220-acb6-ffb04d2fd93a", "name": "l(r:p1rdt6354-p1rdt6356)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2040b1a2-85bc-405a-9dab-138561b5e3ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a05e7c9-4bff-46fd-b356-8120b481b053"}}}], "length": {"value": 0.017765, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d633367e-1657-4af7-9dfa-e9d06c37122b", "name": "l(r:p1rdt6347-p1rdt6356)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7166849-6ecd-4270-bf52-d0579838336a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1bdfc1ac-98a4-43dd-bb2c-837d0a2c15f9"}}}], "length": {"value": 0.633788, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5911af5d-66da-477a-9570-565ddc5292fb", "name": "l(r:p1rdt7598-p1rdt7605)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e36f1f1-6993-46b0-bafa-9530fd1652ef"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f95e5fa5-a84c-42a4-b519-8d344e816ecd"}}}], "length": {"value": 0.10583000000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "dd01fae1-634b-400c-a135-5dd7242a7e81", "name": "l(r:p1rdt7589-p1rdt7605)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f9809eb-41e0-40a8-b43a-93556f767f68"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e36f1f1-6993-46b0-bafa-9530fd1652ef"}}}], "length": {"value": 0.43683900000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1441ec02-dff2-4e01-af50-3ee3779998cb", "name": "l(r:p1rdt7589-p1rdt7612)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f9809eb-41e0-40a8-b43a-93556f767f68"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3410d88a-3e9c-427e-a79e-5c602455ed1d"}}}], "length": {"value": 0.525437, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "58ab57ef-9ed9-40ab-a4a0-72c5c4f3b6f6", "name": "l(r:p1rdt6347-p1rdt7589)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7166849-6ecd-4270-bf52-d0579838336a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f9809eb-41e0-40a8-b43a-93556f767f68"}}}], "length": {"value": 0.816381, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d601e0c8-87fa-4c4d-91e4-db629622c5ab", "name": "l(r:p1rdt6347-p1rdt8470)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6163371c-55ef-4900-a3ef-2e4e8fc2894a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7166849-6ecd-4270-bf52-d0579838336a"}}}], "length": {"value": 1.6455, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f9d802d6-7774-4bcd-92c8-41fed7e7cdec", "name": "l(r:p1rdt5218-p1rdt5653)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "769c14db-ac3f-438d-9f7d-c7eb2d3074b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98f2c16a-cdbd-49a3-b60d-4be6e9158480"}}}], "length": {"value": 0.123439, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ebc30854-15d0-4059-a4e4-a3b1a8071a39", "name": "l(r:p1rdt5218-p1rdt5653)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98f2c16a-cdbd-49a3-b60d-4be6e9158480"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dda7f7c-3b21-46a0-88a3-2b7f028b7772"}}}], "length": {"value": 0.122523, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4714a056-deff-4fcb-be44-1619b12bc118", "name": "l(r:p1rdt5195-p1rdt5653)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58c6d858-d457-4fe6-a45b-b9b2b73cad8c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fbc486eb-4f08-4602-a101-1298d4a46b32"}}}], "length": {"value": 0.10076600000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "242b9fb2-b832-46a9-b745-db7185470528", "name": "l(r:p1rdt6995-p1rdt7015)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3741c9d4-d03a-4b2f-be57-52a8977351ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d4d11a9-8de3-4dbe-8974-6005ed40f363"}}}], "length": {"value": 0.232606, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "699b5de4-087d-4717-9489-fb69e110294a", "name": "l(r:p1rdt6995-p1rdt7015)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d4d11a9-8de3-4dbe-8974-6005ed40f363"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6278a0d-f5d3-4b11-aee9-3bb23f9954a8"}}}], "length": {"value": 0.0860291, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f53d6c08-324f-49c9-9c3e-83864f308dc5", "name": "l(r:p1rdt16638-p1rdt16725)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c0d417e-c787-4b0a-a39e-b19ef274b36b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2d0eb0b-bbb6-4b3e-bdc6-4c8a0e7d466f"}}}], "length": {"value": 0.163486, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "176d8831-9ba5-4d7b-865b-99ea7e6aa381", "name": "l(r:p1rdt16638-p1rdt6995)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3741c9d4-d03a-4b2f-be57-52a8977351ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddb8e50b-2619-4e74-aee6-84dc4e11389e"}}}], "length": {"value": 0.166099, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b817c266-305b-4ad6-afa6-cdbd5b7def69", "name": "l(r:p1rdt16638-p1rdt6995)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddb8e50b-2619-4e74-aee6-84dc4e11389e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c0d417e-c787-4b0a-a39e-b19ef274b36b"}}}], "length": {"value": 4.23424, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "045afc0b-2012-4ca8-a295-71783d57d765", "name": "l(r:p1rdt5195-p1rdt6995)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58c6d858-d457-4fe6-a45b-b9b2b73cad8c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9056795d-5c81-4fb9-96bc-51d63b32b187"}}}], "length": {"value": 0.168784, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6a994cb4-f5f1-4df2-8d5e-c05435989755", "name": "l(r:p1rdt5195-p1rdt6995)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9056795d-5c81-4fb9-96bc-51d63b32b187"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3741c9d4-d03a-4b2f-be57-52a8977351ad"}}}], "length": {"value": 0.659388, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5c99986b-343d-4b8d-beb5-8d646498648b", "name": "l(r:p1rdt5195-p1rdt5202)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "227d848c-cddc-4561-996b-f8f7a60a5a89"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43e1b69a-c6dd-447e-82d9-921998de9837"}}}], "length": {"value": 0.168993, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bce828da-59ac-4d79-a897-197182228522", "name": "l(r:p1rdt5195-p1rdt5202)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43e1b69a-c6dd-447e-82d9-921998de9837"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e2f2704-4dee-4c78-b199-256b907156f3"}}}], "length": {"value": 0.111644, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "459455e3-ceff-404b-b7ce-cf80495c6db9", "name": "l(r:p1rdt5195-p1rdt5202)_s2", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e2f2704-4dee-4c78-b199-256b907156f3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58c6d858-d457-4fe6-a45b-b9b2b73cad8c"}}}], "length": {"value": 0.284889, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "14d0c4b1-b98e-469a-a68c-82291e282126", "name": "l(r:p1rdt5202-p1rdt5206)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97e4f179-9d60-4183-8326-eb0ab98a53eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17fedb14-6008-43fd-b7e9-342a113f27a6"}}}], "length": {"value": 0.19259500000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5b4278e7-9191-458b-b6c3-fcf736f69eaa", "name": "l(r:p1rdt5202-p1rdt5206)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17fedb14-6008-43fd-b7e9-342a113f27a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ed081eb-6b56-43b8-9cf8-e7ffdd8222f2"}}}], "length": {"value": 0.0669161, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "45ad7777-5030-4f58-baee-e3f8ffdcaa71", "name": "l(r:p1rdt5202-p1rdt7268)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a21680f1-33a7-44e1-9293-98c6861ba2a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6e61d2f-f75e-4335-aec9-4722942be9f1"}}}], "length": {"value": 0.301796, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5edc97b2-39e7-4ad3-89c4-4701b2b65678", "name": "l(r:p1rdt5202-p1rdt7268)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6e61d2f-f75e-4335-aec9-4722942be9f1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97e4f179-9d60-4183-8326-eb0ab98a53eb"}}}], "length": {"value": 1.26696, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7dcb8149-48f5-40b6-8bf7-d2a9a285cc09", "name": "l(r:p1rdt6349-p1rdt6355)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "88cc1382-6b14-4500-8a21-662fce6a0c0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c1edcfa-e0e4-4493-a9bb-e6033185ce67"}}}], "length": {"value": 0.0974401, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e157dc9b-2c86-419e-b934-ef99e273990b", "name": "l(r:p1rdt6355-p1rdt7224)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eeab7dfa-540c-4275-b159-f6ac4d1350f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "88cc1382-6b14-4500-8a21-662fce6a0c0b"}}}], "length": {"value": 0.455366, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4cbbff52-c85f-4eb7-b673-68e04d17547b", "name": "l(r:p1rdt7224-p1rdt7618)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eeab7dfa-540c-4275-b159-f6ac4d1350f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0fef9b3-a4bd-421c-8a54-cbf6f44c460d"}}}], "length": {"value": 0.282912, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d47ed6f4-4d52-4f70-a3e9-8fc6abdfb2c8", "name": "l(r:p1rdt7224-p1rdt7268)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a21680f1-33a7-44e1-9293-98c6861ba2a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22978d10-c9dc-4c84-8025-5749c730daa6"}}}], "length": {"value": 0.593134, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "2804c4ab-653b-4383-9793-17d37549fd78", "name": "l(r:p1rdt7224-p1rdt7268)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22978d10-c9dc-4c84-8025-5749c730daa6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eeab7dfa-540c-4275-b159-f6ac4d1350f9"}}}], "length": {"value": 0.197971, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c8da4fda-f3b6-4e5e-80ad-e99478be3bf2", "name": "l(r:p1rdt7268-p1rdt8470)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6225b33-2abc-4f77-9d65-459794f56353"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a21680f1-33a7-44e1-9293-98c6861ba2a5"}}}], "length": {"value": 1.40851, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8da487d2-4b45-4418-bfbc-c0dea1344931", "name": "l(r:p1rdt7735-p1rdt7790)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97198258-8ba3-4950-8747-3241c6a4fcee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62078787-3ae2-47b3-8f67-8e89e110c8be"}}}], "length": {"value": 0.206801, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f413d80b-c84b-4b47-b903-13ba7aaeb14e", "name": "l(r:p1rdt7790-p1rdt9090)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15a7847f-aa96-4206-b4c6-422802f4e0a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97198258-8ba3-4950-8747-3241c6a4fcee"}}}], "length": {"value": 0.246196, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "280746d1-8633-4f46-b5b2-5c3366afa2a9", "name": "l(r:p1rdt8911-p1rdt9384)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26613f51-86bf-4ae1-86c0-f23e48cf606e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7bc7d623-3ca7-4c4e-b11c-f373e90d06b6"}}}], "length": {"value": 0.11493, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4ea02402-fbd7-4f93-a5b3-87c7cba41c90", "name": "l(r:p1rdt8911-p1rdt9384)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7bc7d623-3ca7-4c4e-b11c-f373e90d06b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6eb9c7a5-5ab1-4d9b-a59e-538b68ad0bb9"}}}], "length": {"value": 0.0369839, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "76520eb4-9022-455a-95e2-68615f432757", "name": "l(r:p1rdt8905-p1rdt8911)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "924fc042-6ddc-484b-b09f-c65b35817d25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26613f51-86bf-4ae1-86c0-f23e48cf606e"}}}], "length": {"value": 0.148702, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "fe8ce15c-6fbe-4020-8e5d-d64427fd1c55", "name": "l(r:p1rdt8904-p1rdt8916)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "adcc33f8-72a3-434c-a021-6c5973713a91"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5584edfb-c31e-4e1d-87d3-b8161a59b15b"}}}], "length": {"value": 0.119301, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f35e4490-62b3-46a0-bb93-7194613325c6", "name": "l(r:p1rdt8904-p1rdt8916)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5584edfb-c31e-4e1d-87d3-b8161a59b15b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2edd17c2-6dfb-4f86-8998-b90a99755e96"}}}], "length": {"value": 0.0388388, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0d648254-33db-4f6c-b1a3-a5eb565882e2", "name": "l(r:p1rdt8905-p1rdt8916)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "924fc042-6ddc-484b-b09f-c65b35817d25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "adcc33f8-72a3-434c-a021-6c5973713a91"}}}], "length": {"value": 0.1748, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1f0641a1-24a2-44f6-a540-19f1d775a311", "name": "l(r:p1rdt8905-p1rdt8915)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "361385c6-bb6d-4bbc-ab7d-4a5774e03d82"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "924fc042-6ddc-484b-b09f-c65b35817d25"}}}], "length": {"value": 0.0903932, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "02e7d66a-a59b-4e2b-a49f-babf0eed8b45", "name": "l(r:p1rdt6574-p1rdt8915)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25a9ec20-35b9-4262-a02d-cafa63e5ee42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9ef9958-5d9e-4907-91cd-4c5d099daaf1"}}}], "length": {"value": 0.200113, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "01105eeb-78ae-43ca-8fef-2d73d4dd9715", "name": "l(r:p1rdt6574-p1rdt8915)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9ef9958-5d9e-4907-91cd-4c5d099daaf1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "361385c6-bb6d-4bbc-ab7d-4a5774e03d82"}}}], "length": {"value": 0.502215, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8fd323f7-0f6a-46f6-992e-bf7620907a90", "name": "l(r:p1rdt6574-p1rdt6581)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "599c6ed9-5ff7-4c97-a469-adceecaaf902"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25a9ec20-35b9-4262-a02d-cafa63e5ee42"}}}], "length": {"value": 0.214792, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5c51619f-c22d-4bab-88b1-5e86c6461402", "name": "l(r:p1rdt6581-p1rdt9084)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6114624f-81c8-4d9c-8f9a-3ab73158596e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "599c6ed9-5ff7-4c97-a469-adceecaaf902"}}}], "length": {"value": 0.220787, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8f71b6b2-940e-460b-aca1-395123d090d7", "name": "l(r:p1rdt9076-p1rdt9093)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2ce5116-c4f0-4ac7-a34f-3ba44c99d04b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c29179f3-0b4e-449c-8562-a8fcb675be6c"}}}], "length": {"value": 0.0790457, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "10112fc8-0706-4ca6-a9dc-155f2b62b426", "name": "l(r:p1rdt9076-p1rdt9084)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12b4dc99-fe50-457c-90aa-48a2fb19ebf1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2ce5116-c4f0-4ac7-a34f-3ba44c99d04b"}}}], "length": {"value": 0.143642, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7a562dd7-062c-47c7-a967-a36881222871", "name": "l(r:p1rdt9085-p1rdt9091)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "563c6bb3-d8ed-4fce-ad66-3892426248df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7fcdf409-885c-4c95-834e-988842ed3f5c"}}}], "length": {"value": 0.037383000000000007, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "816469ff-5ef9-491d-a0e5-f0cd167e7249", "name": "l(r:p1rdt9090-p1rdt9091)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf719d10-8168-4d80-894e-1b1516f033e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "563c6bb3-d8ed-4fce-ad66-3892426248df"}}}], "length": {"value": 0.176401, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f21c5d48-35f7-48b8-b0e3-e303cb6e0d3a", "name": "l(r:p1rdt9469-p1rdt9470)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5f6a2ec-3ddd-4ba7-9c55-88b4d82e7735"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acf91e46-ba32-44c3-a829-14c80a693d7d"}}}], "length": {"value": 0.0968012, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4f55c8b3-52d9-48bd-80b9-4336d109293f", "name": "l(r:p1rdt5140-p1rdt5184)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "431b672b-cb45-4294-b1f9-1d63f4efc8db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ceb58d66-3cb3-416d-aedf-f4949432eb37"}}}], "length": {"value": 0.11451800000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "87ff4d03-1265-417f-8396-f2223bf91dc2", "name": "l(r:p1rdt5140-p1rdt5184)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ceb58d66-3cb3-416d-aedf-f4949432eb37"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b0fd055-d0ac-4678-a8e5-679e12741736"}}}], "length": {"value": 0.0332053, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "049715c6-15cd-4adc-bfcb-405451aa8567", "name": "l(r:p1rdt5154-p1rdt5184)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50332aed-ecfd-465a-977e-c24ed6462860"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "431b672b-cb45-4294-b1f9-1d63f4efc8db"}}}], "length": {"value": 0.120991, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "76f0c663-18fa-4b81-a500-c47e1e85102e", "name": "l(r:p1rdt5142-p1rdt5154)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d579047b-82f6-49bf-bd7b-28c818d44bb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50332aed-ecfd-465a-977e-c24ed6462860"}}}], "length": {"value": 0.334614, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "756d1a3b-80d5-45f2-b945-05ac9c864cc7", "name": "l(r:p1rdt5142-p1rdt5180)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d579047b-82f6-49bf-bd7b-28c818d44bb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6316fa2-dd57-46d4-89c0-f11dd675d686"}}}], "length": {"value": 0.304739, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "23f00fb1-3a44-456d-adfc-200b1c385382", "name": "l(r:p1rdt5142-p1rdt8414)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b48f78d-1092-4536-bfb3-029da6a70dff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50f71b3d-83ce-4526-8057-4a38042b7295"}}}], "length": {"value": 0.0685574, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "e62ca4d7-5c98-4352-9f1d-520696b1d502", "name": "l(r:p1rdt5142-p1rdt8414)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50f71b3d-83ce-4526-8057-4a38042b7295"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d579047b-82f6-49bf-bd7b-28c818d44bb3"}}}], "length": {"value": 0.517385, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "591186a8-ed4e-49a7-a103-b77dc41ee44c", "name": "l(r:p1rdt6409-p1rdt8414)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42929633-40d4-4e13-a0aa-a7682f328226"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8648275-54c9-48e3-82e0-33119313924d"}}}], "length": {"value": 0.184195, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "712a1997-2d23-4337-adc2-b4f3245b7797", "name": "l(r:p1rdt6409-p1rdt8414)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8648275-54c9-48e3-82e0-33119313924d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b48f78d-1092-4536-bfb3-029da6a70dff"}}}], "length": {"value": 0.718647, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "40a640c0-70ae-4ede-af89-011fe2f9c3d6", "name": "l(r:p1rdt6409-p1rdt9413)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f750e531-5ade-40a9-9bb0-042220ce9807"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42929633-40d4-4e13-a0aa-a7682f328226"}}}], "length": {"value": 1.30529, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "9557eec3-679c-4760-af42-931b0ecaf811", "name": "l(r:p1rdt7570-p1rdt7574)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9b94106-b7c5-4ce9-9c19-053487848c2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd487832-bc77-406f-a995-4b099fad7c64"}}}], "length": {"value": 0.145959, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "4d38ea75-cd04-43b1-8a35-82c9b0e08cfb", "name": "l(r:p1rdt6275-p1rdt7570)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08d4c459-5bc5-4cad-8e74-613c4a08cb35"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9b94106-b7c5-4ce9-9c19-053487848c2a"}}}], "length": {"value": 0.362236, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "2e63b32d-43ae-42f8-bfbc-1179dc97926a", "name": "l(r:p1rdt6270-p1rdt6275)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cf36152-b3af-49f7-b693-5d465db1f283"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08d4c459-5bc5-4cad-8e74-613c4a08cb35"}}}], "length": {"value": 0.224093, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "a4f133cd-d305-41fc-9adf-8e347daa1943", "name": "l(r:p1rdt6269-p1rdt6270)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5ef97a6-6c60-46eb-acce-6469b273658a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cf36152-b3af-49f7-b693-5d465db1f283"}}}], "length": {"value": 0.284296, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "03db94ff-d792-433b-a8ab-a92dd86752d7", "name": "l(r:p1rdt6269-p1rdt8405)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60829dab-c129-4017-961a-81435d8afa93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5ef97a6-6c60-46eb-acce-6469b273658a"}}}], "length": {"value": 0.466915, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "afade1f8-1732-423e-b3af-635852b088ba", "name": "l(r:p1rdt8405-p1rdt9413)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16ecb938-cd0c-4be5-a915-be0d84d351f2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60829dab-c129-4017-961a-81435d8afa93"}}}], "length": {"value": 1.34967, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "aabe9c80-a880-4171-a383-28382ce12704", "name": "l(r:p1rdt6518-p1rdt9314)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d25f8d60-8aa7-4975-96dc-eba7696fa8ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d39c608-5688-4e22-8ac4-96b896265274"}}}], "length": {"value": 0.0596908, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "c08967c9-6afc-4436-b958-5f3dec162e2a", "name": "l(r:p1rdt9314-p1rdt9479)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b006c3-79f8-4a27-b76a-d1b458ff2a21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d25f8d60-8aa7-4975-96dc-eba7696fa8ae"}}}], "length": {"value": 0.23881800000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d9a45f7b-94cd-476f-b492-6be6d2c3273f", "name": "l(r:p1rdt6539-p1rdt9479)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9707f264-8f82-4483-8337-6c89d709faf7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b006c3-79f8-4a27-b76a-d1b458ff2a21"}}}], "length": {"value": 0.04213, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "5b6a5df1-5751-419e-9043-c59af2cb8468", "name": "l(r:p1rdt6507-p1rdt6539)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0db3e719-4dba-4b45-af70-c35546c19eb4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9707f264-8f82-4483-8337-6c89d709faf7"}}}], "length": {"value": 0.0349385, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "26afa7b6-b653-49b5-bf12-aa3c4938736f", "name": "l(r:p1rdt6507-p1rdt6530)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40ec7437-80f0-49e8-806a-c696b1402713"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0db3e719-4dba-4b45-af70-c35546c19eb4"}}}], "length": {"value": 0.28028700000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "221d6d6b-ad9e-406a-bf03-4b61c0d4feff", "name": "l(r:p1rdt6517-p1rdt6530)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b56340a0-81f0-4028-9283-532f0d92a412"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40ec7437-80f0-49e8-806a-c696b1402713"}}}], "length": {"value": 0.110659, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f60c7b67-fc17-4837-8efd-81efa3b23616", "name": "l(r:p1rdt6517-p1rdt6523)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "608945f2-9b19-43bc-83d9-0fe8787b06b4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b56340a0-81f0-4028-9283-532f0d92a412"}}}], "length": {"value": 0.281764, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "2c421fa7-4dd6-491c-998e-efe7bdb6b9f8", "name": "l(r:p1rdt6520-p1rdt6523)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24028ccd-3fd3-4461-b83c-54266f91a385"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b540c710-395d-4a35-8dc3-59d37609df09"}}}], "length": {"value": 0.0397382, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "ed24a3ca-3bd7-4de6-a546-05dc166ef9c8", "name": "l(r:p1rdt6501-p1rdt6520)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99fa55d1-867c-4db0-8697-b532da10d6d4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24028ccd-3fd3-4461-b83c-54266f91a385"}}}], "length": {"value": 0.0288844, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "be507d1a-0e3c-4956-b874-c26265167d1f", "name": "l(r:p1rdt6499-p1rdt6501)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "89434ebc-1e79-4414-9925-1a14f8e72fd6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99fa55d1-867c-4db0-8697-b532da10d6d4"}}}], "length": {"value": 0.0288269, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "6a77ab95-cadc-4be1-a0fe-1c155f22727c", "name": "l(r:p1rdt6499-p1rdt6509)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67c889f-e940-4242-9c83-4b5ab673d8a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "89434ebc-1e79-4414-9925-1a14f8e72fd6"}}}], "length": {"value": 0.026420600000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "b4fb2c7c-087c-479f-bb54-c153ff040105", "name": "l(r:p1rdt6508-p1rdt6509)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e165d0d-3f13-4d87-9c4b-fdfa8829f1f3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67c889f-e940-4242-9c83-4b5ab673d8a8"}}}], "length": {"value": 0.0278115, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "aac50a47-c224-459e-8507-4369a4d11f3a", "name": "l(r:p1rdt6508-p1rdt6521)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "302d2adf-2199-47b2-9f3c-e428bb409b6f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e165d0d-3f13-4d87-9c4b-fdfa8829f1f3"}}}], "length": {"value": 0.0189224, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f8244459-83a4-4ad3-a604-ec873ed20732", "name": "l(r:p1rdt6512-p1rdt6521)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f7572ed-6443-4e6e-8fb8-0b060b9f17ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "302d2adf-2199-47b2-9f3c-e428bb409b6f"}}}], "length": {"value": 0.0189224, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d5d29e6c-2471-43f5-85e9-7d24f91a352f", "name": "l(r:p1rdt6512-p1rdt6524)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ef8c502-c06f-43e5-90e6-23bd0ebcf155"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f7572ed-6443-4e6e-8fb8-0b060b9f17ce"}}}], "length": {"value": 0.0367319, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "672c8944-7a16-40e8-bdda-3b03fca4fecb", "name": "l(r:p1rdt7091-p1rdt7625)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6372a592-5e2d-41c8-819b-f56bfbb58e19"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2324afa4-5274-4392-9a0e-be8dc2bebeba"}}}], "length": {"value": 0.08221500000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f5dbe138-bea6-41cd-b524-27b90637c6e1", "name": "l(r:p1rdt7091-p1rdt7625)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2324afa4-5274-4392-9a0e-be8dc2bebeba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3e6cbe9-d1d3-4c59-981f-dad980f0999b"}}}], "length": {"value": 0.022555100000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f8e4f44c-08eb-469a-80c1-4f48efd02207", "name": "l(r:p1rdt7091-p1rdt7314)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0cf1844f-a32e-40f2-bc96-05fad3bdd88d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6372a592-5e2d-41c8-819b-f56bfbb58e19"}}}], "length": {"value": 0.55397, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "257675fc-6733-4332-ac51-3675463a4f35", "name": "l(r:p1rdt7314-p1rdt7318)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e86bc267-1607-4aa3-916f-ed826b0adfdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0cf1844f-a32e-40f2-bc96-05fad3bdd88d"}}}], "length": {"value": 0.048033200000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "e1ad2ae6-ae2b-46ab-a690-ea8d77ccc596", "name": "l(r:p1rdt7307-p1rdt7318)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "231b5cf9-ec2c-47d1-aada-5454926561dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e86bc267-1607-4aa3-916f-ed826b0adfdc"}}}], "length": {"value": 0.608118, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "12afdbdb-d635-4f2e-935d-dd9e846d84de", "name": "l(r:p1rdt6531-p1rdt7307)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8431ef4c-78dd-4a39-b15a-95818cfe1d86"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "231b5cf9-ec2c-47d1-aada-5454926561dd"}}}], "length": {"value": 0.626542, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "b628bac6-cc49-4fd0-869c-1e62b4f793f3", "name": "l(r:p1rdt6527-p1rdt6531)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "483b2d65-b496-4c6f-b01d-66aa3d9d4334"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "385eabe4-8c8e-4354-96ec-931e6c25574d"}}}], "length": {"value": 0.0295001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "00137112-a43a-4501-803e-980b8f2c0003", "name": "l(r:p1rdt6516-p1rdt6527)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5bd908fd-8bb8-42c1-8d1b-27c4e2574450"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "483b2d65-b496-4c6f-b01d-66aa3d9d4334"}}}], "length": {"value": 0.010689800000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "94115f94-82fa-4272-8a62-027168f25e3c", "name": "l(r:p1rdt6516-p1rdt6524)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ef8c502-c06f-43e5-90e6-23bd0ebcf155"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6191a237-532b-44e2-86a8-d9ed56b914b5"}}}], "length": {"value": 0.186537, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "5191d34f-932a-42dc-a5d6-0c1c0862b244", "name": "l(r:p1rdt6516-p1rdt6524)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6191a237-532b-44e2-86a8-d9ed56b914b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5bd908fd-8bb8-42c1-8d1b-27c4e2574450"}}}], "length": {"value": 0.014510300000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "310cb070-188c-4ff2-b290-6e36abcf555d", "name": "l(r:p1rdt6500-p1rdt6524)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a3d9ed9-e2e4-4332-89a2-358441869830"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97b7ef3c-ef16-4c4d-8559-722c5c67749a"}}}], "length": {"value": 0.0745596, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "beccb173-6f7b-4721-b3fb-e81b2efdd09f", "name": "l(r:p1rdt6500-p1rdt6515)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "18b822d0-cbe4-48d7-a818-87e25412d241"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0043b26d-8a33-4e32-a963-c4638f943775"}}}], "length": {"value": 0.030964300000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "de841033-13d8-4afb-bc0f-c55d72e49c5f", "name": "l(r:p1rdt6515-p1rdt6528)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04c3a970-215a-4e16-a798-80496ffad438"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8dcd059f-292b-4f7a-96c1-a3dc185f1eec"}}}], "length": {"value": 0.00777706, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "b9b34d6f-9985-4065-9d2f-788d5fa538da", "name": "l(r:p1rdt6528-p1rdt8898)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "918984ec-3b5f-4174-9bca-771bb10e0f60"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0156ae64-03dc-4ec0-89c8-8b09a6fc9090"}}}], "length": {"value": 0.0437869, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "75f64198-30d0-4129-ae28-939b6b4de497", "name": "l(r:p1rdt6532-p1rdt8898)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b51e96e7-2d7f-42af-9115-c9b1cfb3131c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "af1707bf-0b2e-4f76-96e7-c01338300d45"}}}], "length": {"value": 0.019358300000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "f1c45b69-986f-4c1d-aeaa-730d016e991d", "name": "l(r:p1rdt6532-p1rdt8902)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4a0469e-1a4a-466d-b18d-f3017b6415ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f373554-9d8a-4a9c-b418-25e67fbb43a9"}}}], "length": {"value": 0.0333077, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "88bad2e7-4dc4-4e4e-8175-a2a884f68169", "name": "l(r:p1rdt6052-p1rdt8902)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68b101ef-d71a-44d2-b1c2-4fc5e9f62499"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "468b1ce8-18fa-423b-99ca-1f3784437721"}}}], "length": {"value": 0.238793, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "eb115d37-81ae-4650-84a2-ae2f15289db2", "name": "l(r:p1rdt6046-p1rdt6052)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99e2ec8b-60fc-4a79-9eed-0d617babcb1d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49c69b43-f43b-4576-bbfa-d06b1d27de95"}}}], "length": {"value": 0.00843437, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "31a466b8-12d6-4b44-9bbb-89a8c774f869", "name": "l(r:p1rdt6043-p1rdt6046)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be3d7f84-84e7-46fc-a9ce-b3e0cf74d1d3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a147dd91-5597-40ff-93f9-0522ad3c726c"}}}], "length": {"value": 0.00839446, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "70cd133d-d616-4b6b-9e07-48fb34f306c9", "name": "l(r:p1rdt6043-p1rdt6045)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f01bba4-b8e8-45ed-af3b-1ac5a287ad46"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48d6768a-45e6-48a5-b22d-d5d418cb6221"}}}], "length": {"value": 0.04888200000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "f868b3e3-cc69-41ce-bcc7-0f7f802d7449", "name": "l(r:p1rdt6045-p1rdt6047)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34a9d21e-bcf7-4266-9834-60a72878ddd4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0396342e-2dc8-4a01-9da9-513953f9b5fa"}}}], "length": {"value": 0.08483280000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d8f16031-320a-40d2-a4bd-5b0e851ebb6c", "name": "l(r:p1rdt6038-p1rdt6047)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8898950-d712-40dc-99b5-33882b96b225"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34a9d21e-bcf7-4266-9834-60a72878ddd4"}}}], "length": {"value": 0.326021, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "598670a4-8ad9-464f-86c2-e9d706cc1558", "name": "l(r:p1rdt6038-p1rdt7599)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a086b782-3a8d-44e9-9948-cb7f051219e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cfe89e9-a7a8-456d-966b-67429017f456"}}}], "length": {"value": 0.186303, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "7223b7c0-3936-4480-8848-42bffaf1bdd0", "name": "l(r:p1rdt6038-p1rdt7599)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cfe89e9-a7a8-456d-966b-67429017f456"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8898950-d712-40dc-99b5-33882b96b225"}}}], "length": {"value": 2.13472, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "4d3942b3-144d-4b5b-82b8-ec7da5fb43f7", "name": "l(r:p1rdt6221-p1rdt7599)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0809ec5e-d36f-4bea-91b3-962ad6c29606"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a086b782-3a8d-44e9-9948-cb7f051219e3"}}}], "length": {"value": 0.192328, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d39bfedb-aa0c-466a-a29d-3c01eaa13638", "name": "l(r:p1rdt6208-p1rdt6221)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdfc617f-fbfb-4e9a-862e-cd5a296748cb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1a5a109-eee6-46be-be53-3fbe4a406575"}}}], "length": {"value": 0.728973, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "938225b2-6c7d-477d-9191-27d235904197", "name": "l(r:p1rdt6208-p1rdt6221)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1a5a109-eee6-46be-be53-3fbe4a406575"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0809ec5e-d36f-4bea-91b3-962ad6c29606"}}}], "length": {"value": 0.0421438, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "e39ddd12-2c19-406b-9cee-39fbbb7419bc", "name": "l(r:p1rdt6208-p1rdt8805)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "89f0c671-9d27-4dec-bd37-dc6c56f07e5d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdfc617f-fbfb-4e9a-862e-cd5a296748cb"}}}], "length": {"value": 0.531617, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "275d987b-6998-408d-8232-9db51e45c450", "name": "l(r:p1rdt5656-p1rdt5662)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17e89212-bc51-4fc2-83d1-4c74a285be23"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6f2bb66-d966-4228-8a13-96c57e8fbfba"}}}], "length": {"value": 0.240242, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "9904f6ea-b491-47e9-85aa-4261c1779673", "name": "l(r:p1rdt5656-p1rdt5662)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6f2bb66-d966-4228-8a13-96c57e8fbfba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f417a58d-5a47-4310-bac6-e8bb95fffc19"}}}], "length": {"value": 0.0265639, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "4573256d-e96e-413f-ac6b-b2c223599e79", "name": "l(r:p1rdt5183-p1rdt5662)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23f0bb81-3c30-45a5-89ca-2011e3881ddb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a05b2959-a8dd-417b-b566-8f84384a3559"}}}], "length": {"value": 0.290891, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "269826f4-1e62-47ca-aa90-96572f804c44", "name": "l(r:p1rdt5183-p1rdt5662)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a05b2959-a8dd-417b-b566-8f84384a3559"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17e89212-bc51-4fc2-83d1-4c74a285be23"}}}], "length": {"value": 1.81146, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "3f70e4f0-d581-4f32-bd85-f3b84da4c8ca", "name": "l(r:p1rdt4980-p1rdt5183)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35487e15-57cb-4e19-bef7-49074e5eb9ee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23f0bb81-3c30-45a5-89ca-2011e3881ddb"}}}], "length": {"value": 0.269563, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d3c03d49-abd6-4de6-8181-afe2d64d9e2a", "name": "l(r:p1rdt4980-p1rdt5017)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c09f718-9379-4281-86f6-55c46e46aec6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ddb0629-4947-47ca-83f9-9b7c073db235"}}}], "length": {"value": 0.216088, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "1c2a6e83-cb95-42de-bb6b-7b0e1cd4ea71", "name": "l(r:p1rdt4964-p1rdt5017)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7f13598-e628-457c-9ba6-d9a0123e882c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf1c765f-ca54-48cf-806f-6a1b5719c4b0"}}}], "length": {"value": 0.261316, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "eac4420e-03e8-40b1-ad16-db8f5eca18fc", "name": "l(r:p1rdt4964-p1rdt5017)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf1c765f-ca54-48cf-806f-6a1b5719c4b0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c09f718-9379-4281-86f6-55c46e46aec6"}}}], "length": {"value": 0.0641008, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "3b99e76c-8a82-4ca1-a9a0-80ecff2a4603", "name": "l(r:p1rdt4964-p1rdt8154)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42ab6054-1866-49c5-b2ab-3cf27199c1c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb1e0d86-907d-4564-a90e-c1400917d3ca"}}}], "length": {"value": 0.341502, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "55ed643d-0afa-4989-b1fd-d0adb37d81c8", "name": "l(r:p1rdt4964-p1rdt8154)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb1e0d86-907d-4564-a90e-c1400917d3ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7f13598-e628-457c-9ba6-d9a0123e882c"}}}], "length": {"value": 0.865306, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "5492331e-5c0a-4016-8ba0-bdc8e5d4f098", "name": "l(r:p1rdt8151-p1rdt8153)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b44d5021-4fdb-4618-bcb2-237ecf2e10e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40962258-28d3-4406-9e9e-121f373cce25"}}}], "length": {"value": 0.18735, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "05f00c42-916f-4b90-9aa8-833526068343", "name": "l(r:p1rdt8151-p1rdt8153)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40962258-28d3-4406-9e9e-121f373cce25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c794942-d5ce-481f-9c6a-563a2180a4ba"}}}], "length": {"value": 0.010421300000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d252c5f0-0b34-4738-8838-259761123b3c", "name": "l(r:p1rdt8153-p1rdt8154)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42ab6054-1866-49c5-b2ab-3cf27199c1c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b44d5021-4fdb-4618-bcb2-237ecf2e10e4"}}}], "length": {"value": 0.112826, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f7417ff2-16a5-4e81-a26b-dc86e9be6115", "name": "l(r:p1rdt8154-p1rdt9333)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0da91bf8-b687-47df-a7dc-41e6166fd667"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aef77ef-aaaa-4a6e-90ef-87348baaf1a0"}}}], "length": {"value": 0.37829, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "398b071f-89c3-461e-a564-1de7f6d5c967", "name": "l(r:p1rdt8154-p1rdt9333)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aef77ef-aaaa-4a6e-90ef-87348baaf1a0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42ab6054-1866-49c5-b2ab-3cf27199c1c8"}}}], "length": {"value": 0.2985030000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "76623ce2-1798-436d-8d11-cfcdc4e48d8e", "name": "l(r:p1rdt8805-p1rdt9333)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3444af6b-f9d4-4229-b6b2-2114300c3f94"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0da91bf8-b687-47df-a7dc-41e6166fd667"}}}], "length": {"value": 0.4807600000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "b055443b-30b0-4f4b-bbe3-54ed03e935bc", "name": "l(r:p1rdt8802-p1rdt8805)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26ccaeff-3a34-4835-8906-1145148549c6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3444af6b-f9d4-4229-b6b2-2114300c3f94"}}}], "length": {"value": 0.287236, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "62bc44cf-8afa-47da-9b7f-18b3ec7b3fff", "name": "l(r:p1rdt8802-p1rdt9413)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "401576cc-4ad6-42cd-bf1c-4022da720711"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e527bf48-b574-43bd-9a5d-484654dc76fe"}}}], "length": {"value": 1.38145, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "19fd814e-e169-4dc3-a33e-fae841593afd", "name": "l(r:p1rdt8802-p1rdt9413)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e527bf48-b574-43bd-9a5d-484654dc76fe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26ccaeff-3a34-4835-8906-1145148549c6"}}}], "length": {"value": 0.181709, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "06dd8bda-4d2d-43a7-a006-b168f73e922c", "name": "l(r:p1rdt5126-p1rdt9413)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0dafde2-c08e-4624-9212-e0fea9e47c2c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f750e531-5ade-40a9-9bb0-042220ce9807"}}}], "length": {"value": 1.23272, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "243ed967-e94e-485e-8b9d-afcbd257a23f", "name": "l(r:p1rdt5126-p1rdt5342)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c8f9ea6-06fb-4fd0-8629-ceea4f32189f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0dafde2-c08e-4624-9212-e0fea9e47c2c"}}}], "length": {"value": 1.97105, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "1a44ac5c-bd61-4c05-add0-330d7b09af79", "name": "l(r:p1rdt5476-p1rdt7624)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e240270-762d-49f0-a4e4-29fcd6273ce5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b077dc9c-1c6f-4403-ae0c-954e7cc0c692"}}}], "length": {"value": 0.421903, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "cc2acfa4-f76c-49fb-9790-7a02064a106b", "name": "l(r:p1rdt7624-p1rdt8159)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42b9c576-ddba-4be1-bc64-a37d8cbdfa84"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1ab9716-b9f3-44e5-b9f6-cd83d0904dd3"}}}], "length": {"value": 0.172459, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f0f84804-681f-45a5-b03b-c90ab2f2d6ff", "name": "l(r:p1rdt7624-p1rdt8159)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1ab9716-b9f3-44e5-b9f6-cd83d0904dd3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e240270-762d-49f0-a4e4-29fcd6273ce5"}}}], "length": {"value": 0.601263, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "542b2bb0-327d-4aab-a521-e1b0208513fc", "name": "l(r:p1rdt8159-p1rdt8161)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25946c74-15c2-412c-baed-8de5f7aecf98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42b9c576-ddba-4be1-bc64-a37d8cbdfa84"}}}], "length": {"value": 0.18407100000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "007f222e-ee77-4ddd-a2b9-453252e10c12", "name": "l(r:p1rdt7253-p1rdt8470)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f31b09da-e4cc-409e-9634-1907480039ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "442de065-9e2a-4ff8-9100-1298d3fe0f6f"}}}], "length": {"value": 1.51192, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f872437e-3f61-48ba-b719-7dec231c6092", "name": "l(r:p1rdt7248-p1rdt7253)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a006c5f-e960-4ae2-a37f-d23d7b873a22"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f31b09da-e4cc-409e-9634-1907480039ff"}}}], "length": {"value": 0.16946100000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "126d74f6-247e-4072-a5df-2c3d434063f3", "name": "l(r:p1rdt7220-p1rdt7248)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a2f1a631-48f7-4291-9adb-588a66620ebf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a006c5f-e960-4ae2-a37f-d23d7b873a22"}}}], "length": {"value": 0.306328, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "05aee401-6d4c-4709-8f97-3c50231daf5e", "name": "l(r:p1rdt7220-p1rdt8160)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38b72c12-2e2f-4d83-8f5a-9d8503dc29eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a2f1a631-48f7-4291-9adb-588a66620ebf"}}}], "length": {"value": 0.197573, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "95d74719-df14-429b-a976-0df68eb96622", "name": "l(r:p1rdt9075-p1rdt9084)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "907828f5-8e26-41c4-8fbc-a3744608181a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c10b6848-6c57-4243-8cb9-ec28d0a4c9dd"}}}], "length": {"value": 0.178898, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "3eafde29-da04-4c84-8fb6-7f4688eda991", "name": "l(r:p1rdt9075-p1rdt9084)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c10b6848-6c57-4243-8cb9-ec28d0a4c9dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4251587d-600f-40a0-9aec-229fb2e3f2df"}}}], "length": {"value": 0.27713400000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "fd3b2cfd-59b4-44c7-b0e7-303bae472d10", "name": "l(r:p1rdt9075-p1rdt9077)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b7f2f09-976a-45da-8186-229aeedeb689"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "907828f5-8e26-41c4-8fbc-a3744608181a"}}}], "length": {"value": 0.564064, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "347ee642-da70-4556-80d2-c3ac791c95eb", "name": "l(r:p1rdt9077-p1rdt9089)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b4ec275-bea8-45f2-94cb-5e24e82179d8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b7f2f09-976a-45da-8186-229aeedeb689"}}}], "length": {"value": 0.0696185, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f1cb1cc4-91cf-4ec1-a7a3-133827bae335", "name": "l(r:p1rdt9089-p1rdt9090)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52c72b52-1c6c-46f6-adbe-1054eb233c20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e4d2db3-67c5-4fef-996a-5774803c89b1"}}}], "length": {"value": 0.172405, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "fd0103af-8848-4f0a-8530-fac681f8ac46", "name": "l(r:p1rdt9089-p1rdt9090)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e4d2db3-67c5-4fef-996a-5774803c89b1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b4ec275-bea8-45f2-94cb-5e24e82179d8"}}}], "length": {"value": 0.0139334, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "df82aa08-b98c-4a21-89f9-d1b76cfe2af4", "name": "l(r:p1rdt9090-p1rdt9469)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3fd32c7-2866-4699-93a8-dd3a9997d349"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "708803a5-3daf-4892-96e3-b182e2d214ec"}}}], "length": {"value": 0.170175, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "fcb909f2-d354-474b-aee1-a6ca2eb94969", "name": "l(r:p1rdt9090-p1rdt9469)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "708803a5-3daf-4892-96e3-b182e2d214ec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52c72b52-1c6c-46f6-adbe-1054eb233c20"}}}], "length": {"value": 0.101162, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "2825eafe-8b85-450e-bed0-ab9a8e074f2d", "name": "l(r:p1rdt8160-p1rdt9469)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38b72c12-2e2f-4d83-8f5a-9d8503dc29eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3fd32c7-2866-4699-93a8-dd3a9997d349"}}}], "length": {"value": 0.245773, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "13deaf06-081a-4c2c-b09a-13b3d3c7335b", "name": "l(r:p1rdt8160-p1rdt8161)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8ecbd5b-6db5-44a0-b2a8-0233d4eb5b20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc9cbaf2-05bd-49aa-bd14-a363d4970d0f"}}}], "length": {"value": 0.191607, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "c5288543-a096-4660-bf4a-2929c4c54201", "name": "l(r:p1rdt8160-p1rdt8161)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc9cbaf2-05bd-49aa-bd14-a363d4970d0f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38b72c12-2e2f-4d83-8f5a-9d8503dc29eb"}}}], "length": {"value": 0.415051, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "b887aaee-21fc-4122-9966-afa362c2a743", "name": "l(r:p1rdt5236-p1rdt8161)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22db53ea-6d9a-4527-9b36-34a4bcd2c74f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67967bdd-155c-49fd-8d4c-29b40415a243"}}}], "length": {"value": 0.0839258, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f602002d-891a-4cda-82bc-55026a5de403", "name": "l(r:p1rdt5236-p1rdt8161)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67967bdd-155c-49fd-8d4c-29b40415a243"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25946c74-15c2-412c-baed-8de5f7aecf98"}}}], "length": {"value": 0.757497, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "10415944-6d9a-4497-bbb6-d304cebe9536", "name": "l(r:p1rdt5236-p1rdt5342)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9bbfae79-a578-4ff2-b622-3dddd9859ac8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22db53ea-6d9a-4527-9b36-34a4bcd2c74f"}}}], "length": {"value": 1.97703, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f8620c0f-f6b7-4b1c-abcf-c32e418abafc", "name": "l(r:p1rdt5342-p1rhs7_1247)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14208aa5-3197-4c90-adf9-3067dae9b5f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c8f9ea6-06fb-4fd0-8629-ceea4f32189f"}}}], "length": {"value": 0.373586, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "038d8c23-c731-48d4-9f20-56de4007395d", "name": "l(r:p1rdt5154lv-p1rlv10539)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9750085f-4afd-48ee-89f3-edbe9687b242"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08331744-08b7-455e-b2ca-284cae95fb06"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "4897e763-4729-42e4-a83c-2555a1a08472", "name": "l(r:p1rdt7632lv-p1rlv16271)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7235cf3a-dd26-47f7-884c-6335024a3064"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "606bf8f6-d745-4220-8cae-e01ffd22f669"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "323fd365-c57f-480b-9a0d-7f496d60a8db", "name": "l(r:p1rdt7632-p1rdt9265)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b336e76f-17f3-4f5d-ba84-f24c3a4e3eed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36e7cd28-6795-41d5-847d-92347871384f"}}}], "length": {"value": 0.178943, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "78cda3f2-1738-44fb-b107-a25d2930dde8", "name": "l(r:p1rdt5140-p1rdt9265)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b0fd055-d0ac-4678-a8e5-679e12741736"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60837f06-40cb-4f12-b36f-fe5e502c96d9"}}}], "length": {"value": 0.223266, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "455cb6d9-470c-4b2b-bfd7-589240e9226b", "name": "l(r:p1rdt5140-p1rdt9265)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60837f06-40cb-4f12-b36f-fe5e502c96d9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b336e76f-17f3-4f5d-ba84-f24c3a4e3eed"}}}], "length": {"value": 0.0122242, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "97bf6cd1-1211-4a45-8bf3-7091c7785df7", "name": "l(r:p1rdt6279lv-p1rlv13061)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6614f5e-517f-46cf-b049-09337d57228a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d46fd47-37f5-48a0-ba0d-d0746e6e6da3"}}}], "length": {"value": 0.0894278, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "a35032da-9a40-4dfe-ac94-e654ae966ae4", "name": "l(r:p1rdt6270-p1rdt6279)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb21415c-fc85-4197-82e5-545cb7be2ce9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1565cfb-f699-47db-9cbf-a76c32e3ea69"}}}], "length": {"value": 0.141369, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "f782b59f-9336-471b-a725-6924905057a8", "name": "l(r:p1rdt6270-p1rdt6279)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1565cfb-f699-47db-9cbf-a76c32e3ea69"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5c579309-9c05-4bae-ab97-2eca485e5ea7"}}}], "length": {"value": 0.0289817, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "e34d7eec-d2c0-4c8f-b361-a88dcd056e29", "name": "l(r:p1rdt6273lv-p1rlv13050)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07992f45-0c92-4a10-837d-4f58599d9b75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "051eba03-4728-4626-8add-5410b5326dc7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "f937594c-fb88-439e-99c9-fda1597eefef", "name": "l(r:p1rdt6268-p1rdt6273)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2f8b91d-339f-4151-90df-b0cad5c2f05a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d04f281-f394-432b-8b5c-cc1acb741369"}}}], "length": {"value": 0.0655674, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "6952320e-ff8d-460d-a4e6-eaf6036b287a", "name": "l(r:p1rdt6268-p1rdt6276)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b31c2adb-e4f4-4211-aac7-f317bf325d12"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce404489-b775-486b-9379-a30c801f6f94"}}}], "length": {"value": 0.246128, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "10f741eb-d2e6-4be0-af4e-b361024769a0", "name": "l(r:p1rdt6268-p1rdt6276)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce404489-b775-486b-9379-a30c801f6f94"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68d2e030-852f-44f6-9e02-d5587a1fc6a0"}}}], "length": {"value": 0.05302, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "84492e74-9344-46cb-a390-f1e004543e53", "name": "l(r:p1rdt6276-p1rdt6278)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51eefb94-724e-4dfe-9823-0f6cf8f56101"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "315af04d-a032-43a8-a2da-b9e68fd21f39"}}}], "length": {"value": 0.154279, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "62a19b90-201e-4b90-8182-f185a38720e2", "name": "l(r:p1rdt6277-p1rdt6278)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1dd4f893-7921-41c3-9e9e-d33e3680a999"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51eefb94-724e-4dfe-9823-0f6cf8f56101"}}}], "length": {"value": 0.0625926, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "b95ba635-9420-4efc-b1f4-f18ab2981eb2", "name": "l(r:p1rdt6269-p1rdt6277)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5ef97a6-6c60-46eb-acce-6469b273658a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "699595d6-8e08-41b1-8c3a-2aef170bb5f7"}}}], "length": {"value": 0.114982, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "6a531a0c-c604-445f-ad7e-c5819157e2fe", "name": "l(r:p1rdt6269-p1rdt6277)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "699595d6-8e08-41b1-8c3a-2aef170bb5f7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1dd4f893-7921-41c3-9e9e-d33e3680a999"}}}], "length": {"value": 0.0390023, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "fe16e73d-9f26-4912-b410-968f808d698e", "name": "l(r:p1rdt6045lv-p1rlv12555)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70bad714-71c1-4341-ac40-76312417dd03"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc71e486-4a44-466d-bc57-85591b269949"}}}], "length": {"value": 0.0236063, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "5d709edf-06ff-4ca8-9765-3865bab61031", "name": "l(r:p1rdt6052lv-p1rlv12567)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d830a1b-6971-4f4d-99bd-945e0785b5aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29476f95-f85b-4843-a847-3d9d99da3b74"}}}], "length": {"value": 0.0045077400000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "9c40129e-b9c4-4aff-b928-c2e84025b91f", "name": "l(r:p1rdt8902lv-p1rlv19164)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d1c8eb9-7f79-49ad-9e93-6c7cdcc95e22"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a02024b5-aa74-4e07-b043-a7a0e8b3e816"}}}], "length": {"value": 0.034742, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "90dd54ce-1778-49cf-a73f-6ed95b6c2526", "name": "l(r:p1rdt6537lv-p1rlv13720)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3f191ff-f8f2-4f13-af83-e67d1fdd366a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fe1a5da7-bdac-46a6-ab32-addc4f02a296"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "94cd3a09-1d25-466d-9330-f377442a7752", "name": "l(r:p1rdt6530-p1rdt6537)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40ec7437-80f0-49e8-806a-c696b1402713"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "45aca6e5-a8ee-4f45-80f3-e227379d33af"}}}], "length": {"value": 0.308478, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "55ed7480-a266-49da-beec-8b1b0d034468", "name": "l(r:p1rdt6530-p1rdt6537)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "45aca6e5-a8ee-4f45-80f3-e227379d33af"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "902291fa-9561-4f40-a4b7-4fd9fdded417"}}}], "length": {"value": 0.00557178, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "6f8d316a-82f6-4fc7-a734-a3c41faef455", "name": "l(r:p1rdt7313lv-p1rlv15628)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41e61263-feb6-4264-965a-fd1309d997a1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13eabcb1-332a-4c7a-8042-214ada721424"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "48ae8b06-1601-4570-9baa-08a0edd126d2", "name": "l(r:p1rdt7313-p1rdt7318)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e86bc267-1607-4aa3-916f-ed826b0adfdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a3a5e1c-77a2-4a9d-89e0-7d1c94176787"}}}], "length": {"value": 0.478103, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "e93ae957-665d-4d98-9565-61d7fa171d07", "name": "l(r:p1rdt7091lv-p1rlv15196)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0c42b48-7ca4-465f-b17c-048cb5f6d79b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64634ab5-a5b0-45ae-9763-7d0be029350f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "ced3202e-8eab-47a4-a979-fe58903c95a5", "name": "l(r:p1rdt5658lv-p1rlv11679)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f718935b-704d-4374-9172-856511e1eddd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4747e0f3-2a66-4e5a-8160-ac0aabe34489"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "e989189e-1d7f-413f-9447-be9c62919ce6", "name": "l(r:p1rdt5656-p1rdt5658)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f417a58d-5a47-4310-bac6-e8bb95fffc19"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81d6db26-881f-4cae-9514-df4c1e71c76e"}}}], "length": {"value": 0.6035390000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "5ba12d68-d1c2-4a66-b496-c299b151bf39", "name": "l(r:p1rdt5236-p1rdt8138)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0bab7e6b-74a6-4fe4-95e1-4ef96084f730"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22db53ea-6d9a-4527-9b36-34a4bcd2c74f"}}}], "length": {"value": 1.28532, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "3bc006be-04ae-45f9-8629-fd4cc42dcf20"}}}}, {"uuid": "76ff5ca6-d44b-4b4d-b1b5-c14739844a79", "name": "padswitch(r:p1rdt6270-p1rdt6271)p1r_14586", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "658514b3-59fd-44b7-95d6-a34cafcb47c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28954596-f060-4fa8-9f13-dfaa633bb739"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "47f16deb-bd0f-40f8-bed6-ee102cf95311", "name": "padswitch(r:p1rdt6270-p1rdt6271)p1r_14587", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b81bd5c2-96bb-445e-9eb8-d72360fd8a94"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a75c5e2-2277-42b4-87d4-6eadff5c06f1"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "fdb44f5f-12df-415f-a658-fc222a86212f", "name": "padswitch(r:p1rdt6500-p1rdt6519)p1r_14592", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9938a5c-b1cd-4592-814d-324ff2eb6644"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf648a0d-3262-4150-892b-55c3b117050a"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "6ba5defb-3101-4ef8-8d06-36719f7dad94"}}}}, {"uuid": "c2901c9f-984c-4dce-b45c-7e5ed1da1ce4", "name": "padswitch(r:p1rdt6500-p1rdt6519)p1r_14593", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5789c3b2-eb91-4e4c-85e8-24f5893e1a2c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "addd9f38-279f-4d9e-b216-38faef1940c7"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "fa89ef5e-f965-457f-a553-4831f61b03c7"}}}}, {"uuid": "111ecb31-3bbe-454e-8c3b-6d1f70eb1532", "name": "padswitch(r:p1rdt6515-p1rdt6535)p1r_14598", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acd6da90-895c-4d2c-80b4-1712b3949993"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fec078c2-a5d8-4317-a8ac-bc25772f6358"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "6ba5defb-3101-4ef8-8d06-36719f7dad94"}}}}, {"uuid": "bf3c2744-7527-4dae-99cf-5e2e7a4820ff", "name": "padswitch(r:p1rdt6515-p1rdt6535)p1r_14599", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5a05d0e-8cf2-4ab8-bdfd-24b8cd12ad67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b13053e-033e-4fe9-8eb3-89389e4bdc2b"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "fa89ef5e-f965-457f-a553-4831f61b03c7"}}}}, {"uuid": "2d52f48c-71fe-495c-a82d-13c4ed75d340", "name": "padswitch(r:p1rdt6515-p1rdt6536)p1r_14600", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0103161-4b16-4d25-a1f3-5a939317461f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04c1e05a-9cbb-4e53-9412-1cffd3976bed"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "6ba5defb-3101-4ef8-8d06-36719f7dad94"}}}}, {"uuid": "434eb627-cf53-4216-afff-7c43ac807514", "name": "padswitch(r:p1rdt6515-p1rdt6536)p1r_14601", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5aa6899b-19a2-41e6-b445-f9fe2536c8d9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f5cda74-5e33-4c52-8b2c-76bcd5e6c5cb"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "cbd826fb-5ba3-44b3-9c68-e5792dbd9854"}}}}, {"uuid": "28532c28-7be9-4805-8948-6769b876196e", "name": "padswitch(r:p1rdt6500-p1rdt6524)p1r_14594", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78b3b940-c277-441f-b2b3-83525ed85fcb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a3d9ed9-e2e4-4332-89a2-358441869830"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "d1d26e33-dcd5-4938-ad3f-174e4840c4f5", "name": "padswitch(r:p1rdt6500-p1rdt6524)p1r_14595", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97b7ef3c-ef16-4c4d-8559-722c5c67749a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ef8c502-c06f-43e5-90e6-23bd0ebcf155"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "c63cae3a-2224-4eff-aedd-06790f5bf45d", "name": "padswitch(r:p1rdt6500-p1rdt6515)p1r_14596", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1537ab1-dc7c-4bbd-b347-fc740d54fcf7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "18b822d0-cbe4-48d7-a818-87e25412d241"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "fc796329-2b2a-43b9-80c9-88427ef9b994"}}}}, {"uuid": "b26dbf8c-790a-40b5-ba1c-19b30138e3af", "name": "padswitch(r:p1rdt6500-p1rdt6515)p1r_14597", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0043b26d-8a33-4e32-a963-c4638f943775"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78b3b940-c277-441f-b2b3-83525ed85fcb"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "5f815f51-16da-46fa-b9b7-0a247327f57d", "name": "padswitch(r:p1rdt6515-p1rdt6528)p1r_14602", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ef5115d-ad7b-4671-b984-b9fd5969bf61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04c3a970-215a-4e16-a798-80496ffad438"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "a00c74d5-27a7-4365-a4b4-1caa240257e0", "name": "padswitch(r:p1rdt6515-p1rdt6528)p1r_14603", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8dcd059f-292b-4f7a-96c1-a3dc185f1eec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1537ab1-dc7c-4bbd-b347-fc740d54fcf7"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "fc796329-2b2a-43b9-80c9-88427ef9b994"}}}}, {"uuid": "f1f9def4-cddd-4b19-917f-09d63a013c98", "name": "padswitch(r:p1rdt6528-p1rdt8898)p1r_14604", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d887dbc-43bd-413e-8e72-5c95a2ed0be8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "918984ec-3b5f-4174-9bca-771bb10e0f60"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "1faec6b1-7f5b-4dcb-a048-3049e55d8b38", "name": "padswitch(r:p1rdt6528-p1rdt8898)p1r_14605", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0156ae64-03dc-4ec0-89c8-8b09a6fc9090"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ef5115d-ad7b-4671-b984-b9fd5969bf61"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "8e18082d-6d53-447e-b376-04046779e92e", "name": "padswitch(r:p1rdt6532-p1rdt8898)p1r_14606", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9f12ed7-454c-4cc9-a631-377121a07ba5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b51e96e7-2d7f-42af-9115-c9b1cfb3131c"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "2c2bcd91-cbfd-4595-aaff-70019c10c6fa", "name": "padswitch(r:p1rdt6532-p1rdt8898)p1r_14607", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "af1707bf-0b2e-4f76-96e7-c01338300d45"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d887dbc-43bd-413e-8e72-5c95a2ed0be8"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "c28bad83-c114-4053-9c9b-30bbedcabe0b", "name": "padswitch(r:p1rdt6532-p1rdt8902)p1r_14608", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f44ec9b-338a-4ae1-a26b-26422f218c13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4a0469e-1a4a-466d-b18d-f3017b6415ae"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "d6d0f63a-de65-45e9-bdee-6c551b470065", "name": "padswitch(r:p1rdt6532-p1rdt8902)p1r_14609", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f373554-9d8a-4a9c-b418-25e67fbb43a9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9f12ed7-454c-4cc9-a631-377121a07ba5"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "afa67d84-29d7-4458-849e-84ed0e1b595b", "name": "padswitch(r:p1rdt6052-p1rdt8902)p1r_14610", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c10f182d-aa76-4633-9a84-f41e20b97da1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68b101ef-d71a-44d2-b1c2-4fc5e9f62499"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "fa28c17c-346e-462b-82a7-05a8c4f9581e", "name": "padswitch(r:p1rdt6052-p1rdt8902)p1r_14611", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "468b1ce8-18fa-423b-99ca-1f3784437721"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f44ec9b-338a-4ae1-a26b-26422f218c13"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "b7883a9b-3e71-4054-8da3-871e4aca2b0d", "name": "padswitch(r:p1rdt6046-p1rdt6052)p1r_14612", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67bc3ce6-e23d-4899-b0e8-9783225338ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99e2ec8b-60fc-4a79-9eed-0d617babcb1d"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "6f1d6c03-5c03-49ba-8dab-68f7e30ab2cb", "name": "padswitch(r:p1rdt6046-p1rdt6052)p1r_14613", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49c69b43-f43b-4576-bbfa-d06b1d27de95"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c10f182d-aa76-4633-9a84-f41e20b97da1"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "6639a595-3f1b-44a9-86be-51fa881ce680", "name": "padswitch(r:p1rdt6043-p1rdt6046)p1r_14614", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "87e05b2f-c346-452c-9c72-a6db090c3124"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be3d7f84-84e7-46fc-a9ce-b3e0cf74d1d3"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "91227638-fd33-4479-9525-2d57047db981", "name": "padswitch(r:p1rdt6043-p1rdt6046)p1r_14615", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a147dd91-5597-40ff-93f9-0522ad3c726c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67bc3ce6-e23d-4899-b0e8-9783225338ff"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "689b9014-1cdc-4acc-8b3e-df03f6b21e70", "name": "padswitch(r:p1rdt6043-p1rdt6045)p1r_14616", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0396342e-2dc8-4a01-9da9-513953f9b5fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f01bba4-b8e8-45ed-af3b-1ac5a287ad46"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4900e609-ebb1-44db-852b-602449095f15"}}}}, {"uuid": "03180cf9-2727-4493-8873-aff288e916b6", "name": "padswitch(r:p1rdt6043-p1rdt6045)p1r_14617", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48d6768a-45e6-48a5-b22d-d5d418cb6221"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "87e05b2f-c346-452c-9c72-a6db090c3124"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "6d8a26df-5a49-4e47-869d-4d8122f519ba", "name": "padswitch(r:p1rdt6270-p1rdt6279)p1r_14588", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cf36152-b3af-49f7-b693-5d465db1f283"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb21415c-fc85-4197-82e5-545cb7be2ce9"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "7f30a525-3333-4b58-92ea-577806eca7df", "name": "padswitch(r:p1rdt6270-p1rdt6279)p1r_14589", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5c579309-9c05-4bae-ab97-2eca485e5ea7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "632d8db5-5220-4188-94f0-f6131253820b"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "636897ae-1c34-4ac7-a975-9d28d5b5e703", "name": "padswitch(r:p1rdt6268-p1rdt6276)p1r_14590", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "315af04d-a032-43a8-a2da-b9e68fd21f39"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b31c2adb-e4f4-4211-aac7-f317bf325d12"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "e469ce7f-3983-4e1e-8e32-aa82775148e2", "name": "padswitch(r:p1rdt6268-p1rdt6276)p1r_14591", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68d2e030-852f-44f6-9e02-d5587a1fc6a0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2f8b91d-339f-4151-90df-b0cad5c2f05a"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "7a4d0af0-a80d-4a34-9690-847471cef160", "name": "fuse(r:p1rdt5017-p1rdt5200)p1r_17536", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c09f718-9379-4281-86f6-55c46e46aec6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0843e99-e917-473c-bec7-ee0c3ddec601"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "2c1ba8d6-9c7d-4bff-8436-d9ee96d6015c", "name": "fuse(r:p1rdt5180-p1rdt5201)p1r_17572", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6316fa2-dd57-46d4-89c0-f11dd675d686"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86d3f96e-ffe2-459f-a2f1-b63d7bf138b8"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "b5dcf106-1044-4f87-a7f6-75974485309d", "name": "fuse(r:p1rdt5180-p1rdt7988)p1r_17573", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6316fa2-dd57-46d4-89c0-f11dd675d686"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "893d2436-cd6c-40ad-90af-64ba1ac23f6e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "82ed7871-cb02-4db6-91d5-ce60e7d4e1e2", "name": "fuse(r:p1rdt5472-p1rdt5476)p1r_17641", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b077dc9c-1c6f-4403-ae0c-954e7cc0c692"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d69527e6-70b6-43e2-8b9e-7c8570ad5ddf"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770"}}}}, {"uuid": "82617c5e-c2cc-455d-8527-5601ea90767d", "name": "fuse(r:p1rdt5475-p1rdt5476)p1r_17642", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b077dc9c-1c6f-4403-ae0c-954e7cc0c692"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae343ca3-3337-4528-b117-38a51e6d023f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770"}}}}, {"uuid": "ccf9e034-77fc-426b-b591-d140fef045d2", "name": "fuse(r:p1rdt5476-p1rdt5478)p1r_17643", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b077dc9c-1c6f-4403-ae0c-954e7cc0c692"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c977e6c-43f0-4d7e-b19f-82f0de97dab2"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "a4cfd253-7e2b-44c8-ad94-7e49d479f7d6", "name": "fuse(r:p1rdt5658-p1rdt5663)p1r_17692", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81d6db26-881f-4cae-9514-df4c1e71c76e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81f0e00e-bc49-448a-8e69-0569ed6a8c1a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "d9f2eb29-6d43-4a3e-97a3-82df1571da0f", "name": "fuse(r:p1rdt5658-p1rdt7070)p1r_17693", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81d6db26-881f-4cae-9514-df4c1e71c76e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02407b52-58c3-403c-9b5b-38695f435476"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "9b63d6fe-307e-4ee6-b4a9-7f9f2da30a37", "name": "fuse(r:p1rdt5650-p1rdt5662)p1r_17694", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17e89212-bc51-4fc2-83d1-4c74a285be23"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36c3c493-ff68-4bb8-a3f4-043c5f847bd3"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "30827bea-a4e8-4efe-b4d7-efcfb1e9320b", "name": "fuse(r:p1rdt6270-p1rdt6271)p1r_17809", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cf36152-b3af-49f7-b693-5d465db1f283"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "658514b3-59fd-44b7-95d6-a34cafcb47c5"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "f0933dbe-d79b-4dc5-a90e-5baecda8695c", "name": "fuse(r:p1rdt5179-p1rdt6273)p1r_17810", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d04f281-f394-432b-8b5c-cc1acb741369"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9722136-480b-44cb-8b0e-0b3165712688"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "af71c4ff-4d6e-4ab4-9d66-7d164afa30e7", "name": "fuse(r:p1rdt6278-p1rdt8439)p1r_17811", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51eefb94-724e-4dfe-9823-0f6cf8f56101"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19d5304c-574f-4646-8095-d2dcbbea86e7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "29527017-032c-4b43-bd84-238ae4b0d637", "name": "fuse(r:p1rdt6500-p1rdt6519)p1r_17854", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78b3b940-c277-441f-b2b3-83525ed85fcb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9938a5c-b1cd-4592-814d-324ff2eb6644"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "861d64ae-aba6-4135-a3ca-f177438722a2"}}}}, {"uuid": "5ba4b830-feba-4c34-9f6a-d9a4acea95aa", "name": "fuse(r:p1rdt6501-p1rdt9468)p1r_17855", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99fa55d1-867c-4db0-8697-b532da10d6d4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddfa01c0-4d12-4f96-ab50-0082ef9914a6"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "d467c779-b0de-4d04-a83b-e77928c92e89", "name": "fuse(r:p1rdt6505-p1rdt6508)p1r_17856", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e165d0d-3f13-4d87-9c4b-fdfa8829f1f3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0824c21-244b-4d4e-85d6-238ac4908b5a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "e57e9e13-5001-4417-a3f6-ab5934b145e3", "name": "fuse(r:p1rdt6509-p1rdt6514)p1r_17857", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67c889f-e940-4242-9c83-4b5ab673d8a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42f09ae1-037a-4565-9cd2-0187c45b7866"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "dd4f8c56-9e34-4519-b5c5-cbf9f9aef255", "name": "fuse(r:p1rdt6515-p1rdt6535)p1r_17861", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1537ab1-dc7c-4bbd-b347-fc740d54fcf7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acd6da90-895c-4d2c-80b4-1712b3949993"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "ab93cbf0-52fd-4d3d-a7f9-fd7cb4376fa6"}}}}, {"uuid": "f40fc1ae-26eb-4491-bdbb-89a93f0a5ed4", "name": "fuse(r:p1rdt6515-p1rdt6536)p1r_17862", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1537ab1-dc7c-4bbd-b347-fc740d54fcf7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0103161-4b16-4d25-a1f3-5a939317461f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "ab93cbf0-52fd-4d3d-a7f9-fd7cb4376fa6"}}}}, {"uuid": "2aa6f2b8-2a32-42fc-90f2-fa7a8c55098c", "name": "fuse(r:p1rdt6498-p1rdt6516)p1r_17863", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5bd908fd-8bb8-42c1-8d1b-27c4e2574450"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60b93cd6-c9fc-46ef-8b37-6b14d0773df6"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "29b3f03f-9571-4cf7-9677-dfd361d7772d", "name": "fuse(r:p1rdt6518-p1rdt9311)p1r_17864", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d39c608-5688-4e22-8ac4-96b896265274"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95d939ff-e20d-42b3-bb88-f1975f9fa0aa"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770"}}}}, {"uuid": "1b5e8967-c098-465d-af7c-c04a15173c41", "name": "fuse(r:p1rdt6510-p1rdt6523)p1r_17865", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b540c710-395d-4a35-8dc3-59d37609df09"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66b7b2e9-7658-4de0-8197-3829c6179353"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "3dfebf9a-38af-4642-a33a-d6e2ded3d3d3", "name": "fuse(r:p1rdt5728-p1rdt6537)p1r_17866", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "902291fa-9561-4f40-a4b7-4fd9fdded417"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66ef2ffb-e67d-47eb-ae59-194c538ab861"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "99c97fbd-6df7-451e-8cda-f3cbb38af5c8", "name": "fuse(r:p1rdt7036-p1rdt7091)p1r_17967", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6372a592-5e2d-41c8-819b-f56bfbb58e19"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28d17238-8db8-41da-960c-317183423576"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "43c81b03-5700-4da4-8f70-67963aaef0ac", "name": "fuse(r:p1rdt7298-p1rdt7313)p1r_17994", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a3a5e1c-77a2-4a9d-89e0-7d1c94176787"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1f6ad7d-f7ea-4b94-956c-ec4a3b2028d5"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "5536ecf7-d8e7-4008-b350-e418d4c32378", "name": "fuse(r:p1rdt7554-p1rdt7570)p1r_18045", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9b94106-b7c5-4ce9-9c19-053487848c2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2bdb2b51-0526-4995-bb5e-a2bd495488d4"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "6013789b-d1a7-4068-b10a-f2499431a3e3", "name": "fuse(r:p1rdt7559-p1rdt7570)p1r_18046", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9b94106-b7c5-4ce9-9c19-053487848c2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09814176-7891-4fe1-addf-b47aa106c40d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "8c46219e-0ca9-4c62-b0d1-27774f373511", "name": "fuse(r:p1rdt7551-p1rdt7574)p1r_18047", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd487832-bc77-406f-a995-4b099fad7c64"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1d8c14d0-8247-4a44-98c1-4534aa9037a2"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770"}}}}, {"uuid": "15bcd57b-3325-4415-8d0c-e10363a4d084", "name": "fuse(r:p1rdt7553-p1rdt7574)p1r_18048", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd487832-bc77-406f-a995-4b099fad7c64"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f00dd033-8e7c-43af-bd16-1de2954e07be"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "cbed5d9f-5e20-4900-b098-41ced4f2e4c7", "name": "fuse(r:p1rdt7599-p1rdt8492)p1r_18054", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a086b782-3a8d-44e9-9948-cb7f051219e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "605c34bc-3f7c-4eb7-8df0-fcd00d261921"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "87a1de9d-91b1-4052-ab8c-9c01790a77d8", "name": "fuse(r:p1rdt6847-p1rdt7624)p1r_18055", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e240270-762d-49f0-a4e4-29fcd6273ce5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be9350ab-7ad2-4a89-a374-94bf69588d7f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "a063cb46-3701-476f-b259-2890451a38db", "name": "fuse(r:p1rdt7617-p1rdt7625)p1r_18056", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3e6cbe9-d1d3-4c59-981f-dad980f0999b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a11cf3d9-90bb-4de8-b637-6ec9128525ec"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "fc77f72a-a5f7-465d-aa39-93591b6b0878", "name": "fuse(r:p1rdt7621-p1rdt7625)p1r_18057", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3e6cbe9-d1d3-4c59-981f-dad980f0999b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53df7b6e-bd8c-43f2-860d-8869aec5d079"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "d64e4be1-0395-4089-96bf-26178c53784e", "name": "fuse(r:p1rdt7625-p1rdt7631)p1r_18058", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3e6cbe9-d1d3-4c59-981f-dad980f0999b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "460f5de9-8d4f-468a-b67a-b3b05354a9ce"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "09949c3d-86ce-4fb6-a416-b2b63b50edc5", "name": "fuse(r:p1rdt7576-p1rdt8151)p1r_18146", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c794942-d5ce-481f-9c6a-563a2180a4ba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a31fa2-4df8-418a-a215-d0d450ced9a3"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "f0e0af75-4597-4f6c-930a-4e193179b902", "name": "fuse(r:p1rdt8151-p1rdt8155)p1r_18147", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c794942-d5ce-481f-9c6a-563a2180a4ba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0a6628e-afc1-4daf-8a29-7626ac2aa5dd"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "fb5f1e22-94af-4dc6-89b5-0b586358c8cb", "name": "fuse(r:p1rdt8405-p1rdt8445)p1r_18212", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60829dab-c129-4017-961a-81435d8afa93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8c69243-872f-4e25-9d03-82692bbf8779"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "70b85fee-d939-41de-9968-944ff2b25094", "name": "fuse(r:p1rdt8414-p1rdt8456)p1r_18215", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b48f78d-1092-4536-bfb3-029da6a70dff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34054ef8-8942-4471-ac14-43c6a37e5a16"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "85454510-f466-49d9-93d2-1381c0acd28a", "name": "fuse(r:p1rdt6347-p1rdt8470)p1r_18224", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "442de065-9e2a-4ff8-9100-1298d3fe0f6f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6163371c-55ef-4900-a3ef-2e4e8fc2894a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "d0487dc6-e327-4fb9-8124-bce8e04cfc95", "name": "fuse(r:p1rdt7268-p1rdt8470)p1r_18225", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "442de065-9e2a-4ff8-9100-1298d3fe0f6f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6225b33-2abc-4f77-9d65-459794f56353"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "4a4594e8-f914-4990-ba21-6c90a130e917", "name": "fuse(r:p1rdt8901-p1rdt8902)p1r_18292", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f44ec9b-338a-4ae1-a26b-26422f218c13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d21061fa-1011-44f7-8a20-26fcf0550f52"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "861d64ae-aba6-4135-a3ca-f177438722a2"}}}}, {"uuid": "c53f224c-161b-4771-a189-43944175e441", "name": "fuse(r:p1rdt8902-p1rdt9377)p1r_18293", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f44ec9b-338a-4ae1-a26b-26422f218c13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43c862de-b014-4b24-8b34-54dae6edcf5a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "861d64ae-aba6-4135-a3ca-f177438722a2"}}}}, {"uuid": "6f8f40b9-00fa-445b-a260-2f2b7058d7fb", "name": "fuse(r:p1rdt6581-p1rdt9084)p1r_18331", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4251587d-600f-40a0-9aec-229fb2e3f2df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6114624f-81c8-4d9c-8f9a-3ab73158596e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "198bb22e-539d-4ad2-99eb-c99330a282b0", "name": "fuse(r:p1rdt9076-p1rdt9084)p1r_18332", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4251587d-600f-40a0-9aec-229fb2e3f2df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12b4dc99-fe50-457c-90aa-48a2fb19ebf1"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "db412f85-aaee-44e6-b2f7-6c05006c4a3f", "name": "fuse(r:p1rdt7790-p1rdt9090)p1r_18334", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52c72b52-1c6c-46f6-adbe-1054eb233c20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15a7847f-aa96-4206-b4c6-422802f4e0a6"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "e8b8932b-1bea-473d-b138-d323af891be4", "name": "fuse(r:p1rdt9090-p1rdt9091)p1r_18335", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52c72b52-1c6c-46f6-adbe-1054eb233c20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf719d10-8168-4d80-894e-1b1516f033e8"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "36b7e8e3-1a5f-4604-9ffe-b88b6a71ea45", "name": "fuse(r:p1rdt6226-p1rdt9333)p1r_18385", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0da91bf8-b687-47df-a7dc-41e6166fd667"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f6d3fab-3b83-40c9-85c4-cfeddd0d317a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "3bf77ce1-4f77-4f4c-902e-9b4293967914", "name": "fuse(r:p1rdt9469-p1rdt9470)p1r_18407", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3fd32c7-2866-4699-93a8-dd3a9997d349"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5f6a2ec-3ddd-4ba7-9c55-88b4d82e7735"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "7d4a8786-91d9-4845-8fe5-8e8f350b4a94", "name": "fuse(r:p1rdt5730-p1rdt9479)p1r_18410", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b006c3-79f8-4a27-b76a-d1b458ff2a21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e07d8bc1-2f8a-4067-a2a7-b903dd042ce3"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "8b1e7929-00be-4710-9892-83b9f936f05c", "name": "fuse(r:p1rdt5840-p1rdt9479)p1r_18411", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b006c3-79f8-4a27-b76a-d1b458ff2a21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7f9286b-4209-402a-a365-1d27da4efb75"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "2c304709-0eb6-47d1-aa82-ab4b517d007e", "name": "recloser_disswitch(r:p1rdt8802-p1rdt9413)p1r_20691", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f750e531-5ade-40a9-9bb0-042220ce9807"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "401576cc-4ad6-42cd-bf1c-4022da720711"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "140f67fe-0cf8-45a3-8e1d-7cd225dab6f1"}}}}, {"uuid": "84d72fc4-99d1-4474-99ef-ab56621f28e6", "name": "goab_disswitch(r:p1rdt5236-p1rdt5342)p1r_20760", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c8f9ea6-06fb-4fd0-8629-ceea4f32189f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9bbfae79-a578-4ff2-b622-3dddd9859ac8"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "1848ee60-41cc-4072-ae7a-8f2e890e75ff", "name": "goab_disswitch(r:p1rdt6531-p1rdt7307)p1r_20862", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "385eabe4-8c8e-4354-96ec-931e6c25574d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8431ef4c-78dd-4a39-b15a-95818cfe1d86"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "60e69ce7-f8f6-4852-ae1e-694ae07f37f5", "name": "recloser_disswitch(r:p1rdt8405-p1rdt9413)p1r_20975", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f750e531-5ade-40a9-9bb0-042220ce9807"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16ecb938-cd0c-4be5-a915-be0d84d351f2"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "140f67fe-0cf8-45a3-8e1d-7cd225dab6f1"}}}}, {"uuid": "bb69f156-d7c0-40a5-87e3-b6c622faea56", "name": "goab_disswitch(r:p1rdt6208-p1rdt8805)p1r_20999", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3444af6b-f9d4-4229-b6b2-2114300c3f94"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "89f0c671-9d27-4dec-bd37-dc6c56f07e5d"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "b7056dc9-d1ea-4fc2-a609-6d09d60d3fac", "name": "goab_disswitch(r:p1rdt6517-p1rdt6523)p1r_21014", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b540c710-395d-4a35-8dc3-59d37609df09"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "608945f2-9b19-43bc-83d9-0fe8787b06b4"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "c505d68e-64f2-48ac-afb2-f29694bbaa79", "name": "disswitch(r:p1rdt5195-p1rdt5202)p1r_21153", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97e4f179-9d60-4183-8326-eb0ab98a53eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "227d848c-cddc-4561-996b-f8f7a60a5a89"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "ee8a464c-5fc6-41d0-9c41-36add8ffa204", "name": "goab_disswitch(r:p1rdt8160-p1rdt8161)p1r_21295", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25946c74-15c2-412c-baed-8de5f7aecf98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8ecbd5b-6db5-44a0-b2a8-0233d4eb5b20"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "0799b34e-32a2-4275-b73b-5d5b98a2674b", "name": "goab_disswitch(r:p1rdt4980-p1rdt5183)p1r_21308", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ddb0629-4947-47ca-83f9-9b7c073db235"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35487e15-57cb-4e19-bef7-49074e5eb9ee"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "ca277d25-50a6-4bf9-becf-59896b3145c3", "name": "l(r:p1rdt6501-p1rdt9468)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e4fd2ed-daa1-4a22-936f-8d51ee928d99"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "edf27f1d-b486-434e-92be-963bdeb26090"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "40a26197-da2a-4e22-a50a-3922efd7762c"}}}}, {"uuid": "22c44cd1-4a06-4e8d-9f99-9f622360b34c", "name": "l(r:p1rdt6501-p1rdt9468)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "edf27f1d-b486-434e-92be-963bdeb26090"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b5695dd-714e-4de1-a63a-f142ff0460e1"}}}], "length": {"value": 0.907254, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e3949704-59de-4ac0-a856-a028f2766fb2", "name": "l(r:p1rdt8902-p1rdt9377)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32e86968-974e-4bcc-b562-1d4209771cf0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e62ba05d-920f-4f55-b1c6-3aa078e0073d"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "40a26197-da2a-4e22-a50a-3922efd7762c"}}}}, {"uuid": "f111d805-c7d0-4e6b-beee-74b482cec4f6", "name": "l(r:p1rdt8902-p1rdt9377)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e62ba05d-920f-4f55-b1c6-3aa078e0073d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61972a50-ce24-4ec1-8535-402665b55a55"}}}], "length": {"value": 1.557306, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3a055c24-acdd-4c3d-8cc6-653f0d8be826", "name": "l(r:p1rdt5195-p1rdt5653)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fbc486eb-4f08-4602-a101-1298d4a46b32"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ccc9dcb-3a72-4f11-9bcf-e3a7f1a21985"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "40a26197-da2a-4e22-a50a-3922efd7762c"}}}}, {"uuid": "313717c1-fa7c-4f6e-b27e-12c06e71e69e", "name": "l(r:p1rdt5195-p1rdt5653)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ccc9dcb-3a72-4f11-9bcf-e3a7f1a21985"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "769c14db-ac3f-438d-9f7d-c7eb2d3074b5"}}}], "length": {"value": 0.915894, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4399bb4b-ec3f-463a-b5d0-16570e8eb9b9", "name": "l(r:p1rdt28lv-p1rlv51)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b3c997d-cd47-439c-aeb9-326e12c2b869"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ccef6af-4bf6-44dc-b292-2bf9503a374a"}}}], "length": {"value": 0.0198886, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4aaad3fe-4de0-4afb-8264-3875d74a560e", "name": "l(r:p1rdt28lv-p1rlv53)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b3c997d-cd47-439c-aeb9-326e12c2b869"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3c62646-6132-41ef-ba14-a06789885cd5"}}}], "length": {"value": 0.0198886, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d32a111a-c62d-4052-bf39-48c43dab30fb", "name": "l(r:p1rdt29lv-p1rlv52)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61fc3980-6aa4-415c-91c1-10d32c7c359c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fec0a162-4b0c-4577-b878-8dbc7c9935fc"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "537e8b73-0d40-4f17-a28d-0aae6b098e14", "name": "l(r:p1rdt30lv-p1rlv62)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d2be3b5-dbfc-4099-af9a-96368e60fe23"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "346dad85-3bf8-41a6-97ea-6b3b40a7f22e"}}}], "length": {"value": 0.028845, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "85b7ab92-76f2-4b11-843c-08ecd9d88d3d", "name": "l(r:p1rdm56-p1rlv54)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c89ec162-cda3-4c40-8833-3fff085538ba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20010301-32ce-4cc0-ab59-04ef3bcd35d7"}}}], "length": {"value": 0.0170492, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ddaa35ee-6a95-4aea-8dd8-4c94f1fce2c3", "name": "l(r:p1rdm56-p1rdt30lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d2be3b5-dbfc-4099-af9a-96368e60fe23"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c89ec162-cda3-4c40-8833-3fff085538ba"}}}], "length": {"value": 0.0189193, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9b7fb251-9269-4d78-8c55-47059d037541", "name": "l(r:p1rdm58-p1rlv55)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59ff3c1b-38f4-4a33-86fa-e956951c0f2c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36bdbc4e-edfa-425a-8e4c-e6123b567555"}}}], "length": {"value": 0.013887, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "859a2d9c-f5ee-4913-8ea2-6fdfbcfab2b9", "name": "l(r:p1rdm60-p1rlv152)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f678ceb4-b717-44a5-9db9-f698bece6935"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25b891ce-797a-4a4d-b664-4225fba806c4"}}}], "length": {"value": 0.0140747, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "aa7cc74b-1797-4884-9885-e3500e2380d9", "name": "l(r:p1rdm58-p1rdm60)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59ff3c1b-38f4-4a33-86fa-e956951c0f2c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f678ceb4-b717-44a5-9db9-f698bece6935"}}}], "length": {"value": 0.0566856, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7fb3cf19-7676-4fc4-ab81-0e769d75d414", "name": "l(r:p1rdm58-p1rdt31lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3510eedd-535c-4e58-b81e-c5ec09030479"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59ff3c1b-38f4-4a33-86fa-e956951c0f2c"}}}], "length": {"value": 0.0140094, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d9c6db05-7bc3-4ad3-84d9-f60e07fa7a5f", "name": "l(r:p1rdm59-p1rlv58)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a0a4841-bf31-4498-98d9-115cc159981c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a32ee184-f677-4333-b7ee-7bc30ab41467"}}}], "length": {"value": 0.0220532, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "19418b76-199d-4da4-a457-d31bd2cc8bd2", "name": "l(r:p1rdm59-p1rdt31lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3510eedd-535c-4e58-b81e-c5ec09030479"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a0a4841-bf31-4498-98d9-115cc159981c"}}}], "length": {"value": 0.0494128, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8b247c95-6202-4fe5-940d-4492e1bffb6c", "name": "l(r:p1rdt32lv-p1rlv414)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e374d6d6-1e75-4808-b65a-c7033e1bd528"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec2c1edd-78b1-4436-85cc-2fbc7d880b87"}}}], "length": {"value": 0.00981453, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f0dff6bc-98c3-4316-b25d-c48ba2181493", "name": "l(r:p1rdm61-p1rlv56)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cef7aa37-7ca0-4130-9bcd-1804a811245a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4694811a-ba43-4c78-b957-5209b1d961e2"}}}], "length": {"value": 0.0329346, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3bbc54a5-ff57-420e-b9f4-554e9a130e80", "name": "l(r:p1rdm61-p1rdt32lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e374d6d6-1e75-4808-b65a-c7033e1bd528"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cef7aa37-7ca0-4130-9bcd-1804a811245a"}}}], "length": {"value": 0.0318291, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6fc81b07-6ca8-4ea4-8296-3a5318abe131", "name": "l(r:p1rdt33lv-p1rlv170)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "065c8583-45e5-466c-b4c0-1c66bf970abe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f7dbd18-1cbe-49d3-b490-3c46cf8e37f1"}}}], "length": {"value": 0.0380059, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "16b7dcf9-eccc-4d50-bf94-8699ecae0e2f", "name": "l(r:p1rdm63-p1rlv57)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0538c66-18d7-440e-9efd-6b2945d50f2b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "925cb3b7-4ced-4a36-913f-e6851ed79b98"}}}], "length": {"value": 0.030867800000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2bdd73c1-d6c6-46df-925e-e5b975ebcf7e", "name": "l(r:p1rdm63-p1rdt33lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "065c8583-45e5-466c-b4c0-1c66bf970abe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0538c66-18d7-440e-9efd-6b2945d50f2b"}}}], "length": {"value": 0.0345517, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "83b76af1-5305-4dbc-bb4d-1ae26fa9de1d", "name": "l(r:p1rdm64-p1rlv61)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfa2eaff-b163-46ce-b6e5-516680d39bc3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d22bf2f5-74cc-47c7-ae3b-410fba27c113"}}}], "length": {"value": 0.0241386, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3898954b-b312-40ab-ac32-628c8dce2ca0", "name": "l(r:p1rdm64-p1rdt33lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "065c8583-45e5-466c-b4c0-1c66bf970abe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfa2eaff-b163-46ce-b6e5-516680d39bc3"}}}], "length": {"value": 0.0177518, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "02917748-21d7-4d1d-ba3e-9a59a7f04498", "name": "l(r:p1rdm66-p1rlv59)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72ee0111-4849-4280-b3c9-c0627d1a6c09"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b80bdb24-4bbf-4a57-bd5f-6a5ec9d484dd"}}}], "length": {"value": 0.024402100000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a261116f-a80b-4209-9176-cbc942356177", "name": "l(r:p1rdm66-p1rdt34lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "553a6868-acec-4492-a52d-5aa08414c612"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72ee0111-4849-4280-b3c9-c0627d1a6c09"}}}], "length": {"value": 0.0174345, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "efad20b9-c489-41bc-9b18-f645e0471962", "name": "l(r:p1rdm67-p1rlv67)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "713c1538-ceb4-46df-a996-6c591c0f8e40"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64a67ed2-a563-4378-b6ac-d9a95339e862"}}}], "length": {"value": 0.0188395, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "068b2a22-12d1-4431-9876-767c11d1380a", "name": "l(r:p1rdm67-p1rdt34lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "553a6868-acec-4492-a52d-5aa08414c612"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "713c1538-ceb4-46df-a996-6c591c0f8e40"}}}], "length": {"value": 0.009885930000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "57f5dec5-fde4-48bd-927b-f6e8e3ee8902", "name": "l(r:p1rdt35lv-p1rlv60)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f98cc066-fca3-4489-9770-047caee3e742"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7eb0d1e8-f85e-493e-b69b-26437fdb8ad9"}}}], "length": {"value": 0.0469606, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "dab845c7-99b1-4cc4-8b7b-5a2a0dd8bc4c", "name": "l(r:p1rdm69-p1rlv65)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23861598-ab3c-4648-9de9-3ee4316f2cb4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e00fd9b-92b3-49c4-bcc2-957b9d2c7bad"}}}], "length": {"value": 0.0500401, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "46a3c80f-7d6c-48a5-8c7e-9fbd9a1b6494", "name": "l(r:p1rdm69-p1rdt35lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f98cc066-fca3-4489-9770-047caee3e742"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23861598-ab3c-4648-9de9-3ee4316f2cb4"}}}], "length": {"value": 0.0188806, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9b42fd7d-449c-4d4e-adea-0857666843b0", "name": "l(r:p1rdt36lv-p1rlv63)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a4fb658-c3ba-428a-82bf-b38ae68dd908"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8300f90c-9a3b-400d-af04-072125dce84f"}}}], "length": {"value": 0.0205644, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b4da0dcf-1635-44fc-9cfa-33fecce7b0c4", "name": "l(r:p1rdm71-p1rlv64)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "074f23bd-2fb2-4480-ae4b-f1c1f754613e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5efd07ee-012a-40a4-97bb-07c1a5ed898c"}}}], "length": {"value": 0.0292333, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6bf40a82-f525-451a-b200-2331216a8321", "name": "l(r:p1rdm72-p1rlv162)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "590e467f-47a6-4c7e-ae3a-83cec8dd87e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3fcd1ee-e6e0-4ca3-aacf-cc527b07482a"}}}], "length": {"value": 0.0254773, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "11fdc903-3137-4c9b-940d-6dfaefc83a72", "name": "l(r:p1rdm71-p1rdm72)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "074f23bd-2fb2-4480-ae4b-f1c1f754613e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "590e467f-47a6-4c7e-ae3a-83cec8dd87e3"}}}], "length": {"value": 0.0457287, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1bba3325-6f85-4fd1-8d29-a1bf18d1c001", "name": "l(r:p1rdm71-p1rdt37lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90a16370-67f7-4abd-992c-990d1eb8f17e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "074f23bd-2fb2-4480-ae4b-f1c1f754613e"}}}], "length": {"value": 0.0378897, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1e35ea63-0b7a-4e0b-b5fa-533a1e06f848", "name": "l(r:p1rdm73-p1rlv457)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35807695-5d6d-4544-a748-a96c56b705d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6278f6ee-7332-4de8-9d2c-83bb637f489f"}}}], "length": {"value": 0.020988, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a802ba01-a073-46dc-a10c-aa18ea2dbc0e", "name": "l(r:p1rdm73-p1rdt37lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90a16370-67f7-4abd-992c-990d1eb8f17e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35807695-5d6d-4544-a748-a96c56b705d1"}}}], "length": {"value": 0.0568504, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "70ad305b-4b65-4e83-8e65-943e35a8510a", "name": "l(r:p1rdm74-p1rlv66)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "352f8404-f923-468a-92a5-1be2f82ffb97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e90eb8a2-5db0-4861-96ef-a6991a0386eb"}}}], "length": {"value": 0.0137711, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5adb5955-448c-40e5-95ec-8933d9be1689", "name": "l(r:p1rdm74-p1rdt38lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "752aca33-7682-4e8c-a8b1-624467e02958"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "352f8404-f923-468a-92a5-1be2f82ffb97"}}}], "length": {"value": 0.0186134, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "851de1c3-1505-4685-909f-6eddfe850ab2", "name": "l(r:p1rdm75-p1rlv68)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2332f175-22ca-4894-b63d-246f5c11c572"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c22aa2c8-a6fc-4b27-a875-e07e3f50ecac"}}}], "length": {"value": 0.0220855, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "eb01a68d-63ea-47e1-a68a-7afd7773560d", "name": "l(r:p1rdm75-p1rdt38lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "752aca33-7682-4e8c-a8b1-624467e02958"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2332f175-22ca-4894-b63d-246f5c11c572"}}}], "length": {"value": 0.0568453, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c0d8734c-4318-43b0-9e1e-c11ab3c1271b", "name": "l(r:p1rdm76-p1rlv69)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "131099af-6f69-4531-bebf-e457ff5d7624"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "876ffb0b-f33c-45b2-a085-7b34103ecffc"}}}], "length": {"value": 0.0355524, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "145e3aee-da52-4de2-a9a0-0cf95e1a2b11", "name": "l(r:p1rdm76-p1rdt39lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "623ec6b4-cb70-4437-9d79-5ec577bc3199"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "131099af-6f69-4531-bebf-e457ff5d7624"}}}], "length": {"value": 0.0177535, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "06a16ec9-6153-49da-a2be-542e268a7b4b", "name": "l(r:p1rdm77-p1rlv70)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a909c826-1682-47f0-926c-0a67c9ff2a3a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e53e7714-06d1-4f85-89c5-f152629e8ab7"}}}], "length": {"value": 0.0326608, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f396975a-7f86-4dd3-ad16-b797849c3c9b", "name": "l(r:p1rdm77-p1rdt39lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "623ec6b4-cb70-4437-9d79-5ec577bc3199"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a909c826-1682-47f0-926c-0a67c9ff2a3a"}}}], "length": {"value": 0.0177617, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5a53052c-73d6-4ee8-a0c2-559a73722330", "name": "l(r:p1rdt40lv-p1rlv143)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d08444c-79a3-4ba0-8c69-1855a600dea0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "46cd88d0-b2c4-492a-af3d-d9ae886d0089"}}}], "length": {"value": 0.016125500000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "482a0e0c-58d8-4958-aba7-344577c6f03f", "name": "l(r:p1rdm78-p1rlv71)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "435b1814-b0a6-40e3-a446-efe5b7fce133"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d7791de-0cf6-4901-8b95-2d67870f09f5"}}}], "length": {"value": 0.025679000000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2656656a-d2e7-49e3-9554-4cfd0e1b3ca5", "name": "l(r:p1rdm78-p1rdt40lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d08444c-79a3-4ba0-8c69-1855a600dea0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "435b1814-b0a6-40e3-a446-efe5b7fce133"}}}], "length": {"value": 0.0167754, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f87e81cc-c8a8-40ae-8e3f-0ac8561cdefe", "name": "l(r:p1rdt41lv-p1rlv72)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "793d0bf4-4d9f-4df4-bc95-d528dd7d31d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc710fc3-ae5f-478e-997b-85467db7c93c"}}}], "length": {"value": 0.02597, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e52746d2-07d5-4974-a61e-ff8b224c2504", "name": "l(r:p1rdt41lv-p1rlv88)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "793d0bf4-4d9f-4df4-bc95-d528dd7d31d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "188047cd-3f14-4240-91fe-30113d48152b"}}}], "length": {"value": 0.00984838, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6b64c3a9-ba1b-4cdf-ad7f-e5db328b835d", "name": "l(r:p1rdt42lv-p1rlv86)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8fb27dc9-b404-49d1-84dd-0cde418b037d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "540e0121-fc39-4c2c-9fbc-012c020f5994"}}}], "length": {"value": 0.0169027, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f58b52b9-f373-436c-9298-a94f37865466", "name": "l(r:p1rdm82-p1rlv73)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5f4300c-037f-42b5-a390-31ec1e8396b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4e2991c-1404-44da-bbb5-5a2ebc43bde4"}}}], "length": {"value": 0.025469700000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fd2626d9-6e6e-40a6-b779-ae761e65eaac", "name": "l(r:p1rdm86-p1rlv108)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5696ebea-257d-4cc1-9ae4-61c98563b706"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "afc70b80-ab76-440c-b05b-149458051675"}}}], "length": {"value": 0.05240000000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4cd09994-2b8e-4ac2-b56f-ee68addc1a41", "name": "l(r:p1rdm82-p1rdm86)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5f4300c-037f-42b5-a390-31ec1e8396b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5696ebea-257d-4cc1-9ae4-61c98563b706"}}}], "length": {"value": 0.0153424, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7708cca7-aa53-4b77-befd-c39e45b72c32", "name": "l(r:p1rdm82-p1rdt42lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8fb27dc9-b404-49d1-84dd-0cde418b037d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5f4300c-037f-42b5-a390-31ec1e8396b3"}}}], "length": {"value": 0.0153436, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e84c77e4-d941-4bb3-8e2f-0af560052a45", "name": "l(r:p1rdm83-p1rlv75)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49a07eb5-9c9b-479c-a345-b09f72725a21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ef51371-3fa2-400a-a2b4-3afa97ff2419"}}}], "length": {"value": 0.0103792, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "927bf580-0b67-4304-a620-9bc0dbd749e8", "name": "l(r:p1rdm83-p1rlv130)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49a07eb5-9c9b-479c-a345-b09f72725a21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5c96953-6710-4765-b5bd-4359e03e4c63"}}}], "length": {"value": 0.0354711, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "5634d407-bc77-4db0-b887-faa3d8d89dfd", "name": "l(r:p1rdm84-p1rlv79)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae45c08d-f629-4ff9-9c23-838b6e34da88"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4dd2283-6100-48ce-b4bc-0e37b7b4e409"}}}], "length": {"value": 0.0190078, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ead30048-de23-480f-aaa4-ed9fe5b1fc46", "name": "l(r:p1rdm87-p1rlv115)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d93360fa-3106-4444-9488-e73c6997ab71"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "919a48e8-b378-4dd5-8e33-a2602fb58bc0"}}}], "length": {"value": 0.0121631, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9d97061e-2727-4ac2-b9bf-80ebbfc55484", "name": "l(r:p1rdm84-p1rdm87)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae45c08d-f629-4ff9-9c23-838b6e34da88"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d93360fa-3106-4444-9488-e73c6997ab71"}}}], "length": {"value": 0.0078607, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "53544628-331d-4655-91a4-0552645c049b", "name": "l(r:p1rdm83-p1rdm84)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49a07eb5-9c9b-479c-a345-b09f72725a21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae45c08d-f629-4ff9-9c23-838b6e34da88"}}}], "length": {"value": 0.0149995, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1ac77898-6235-494c-b7f1-3d2c55ee09bb", "name": "l(r:p1rdm83-p1rdt42lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8fb27dc9-b404-49d1-84dd-0cde418b037d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49a07eb5-9c9b-479c-a345-b09f72725a21"}}}], "length": {"value": 0.0149938, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d4818ca2-9988-4682-8047-75b4f8e1b705", "name": "l(r:p1rdm90-p1rlv117)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b812c54c-1689-47cf-beba-55faea943380"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e6de569-7f61-439e-a402-850c4f071ab3"}}}], "length": {"value": 0.0134175, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "41a7ab78-9dfe-4430-89b0-f3ba5c13ff28", "name": "l(r:p1rdm90-p1rdt43lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "274aa0ec-f229-454c-b52d-23130bacb97e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b812c54c-1689-47cf-beba-55faea943380"}}}], "length": {"value": 0.0542235, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6bfac725-d1e2-41cf-ad2e-86634eae8994", "name": "l(r:p1rdm91-p1rlv137)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c82df28-72fa-4cf0-a844-8a6bf90e548b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54ca5205-5b71-42f2-8e24-c24f768a7a5c"}}}], "length": {"value": 0.0263424, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c4bc0a7f-44b6-4f0d-976c-999ec209e06f", "name": "l(r:p1rdm89-p1rlv74)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acbf36c3-9c53-417f-98c1-fa1b5d4b60f4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5861410e-9d6d-423e-b967-2f2af65610b8"}}}], "length": {"value": 0.0187311, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "83961bfa-b775-448b-8caf-405871623580", "name": "l(r:p1rdm89-p1rdm91)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c82df28-72fa-4cf0-a844-8a6bf90e548b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acbf36c3-9c53-417f-98c1-fa1b5d4b60f4"}}}], "length": {"value": 0.0145778, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d8f254e6-7113-400b-92d5-364565ba1e80", "name": "l(r:p1rdm91-p1rdt43lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "274aa0ec-f229-454c-b52d-23130bacb97e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c82df28-72fa-4cf0-a844-8a6bf90e548b"}}}], "length": {"value": 0.0145786, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "db357783-b1b2-4ffd-aca8-8ab881b6c351", "name": "l(r:p1rdt44lv-p1rlv76)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c813f8a2-226b-431d-a41a-195cf5e8b01a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3354497f-6de7-405d-9fca-a9c77463dc27"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "82e7c04e-ab13-4355-9b05-434f456065ad", "name": "l(r:p1rdm93-p1rlv77)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5151d03-c8b3-41f2-a2cd-743aa8ea0fea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f88a22a3-7e6c-4fc5-a8f4-a08cdaa3f5d6"}}}], "length": {"value": 0.0172005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ce7f90cf-c8da-460b-8111-0ea157b77973", "name": "l(r:p1rdm94-p1rlv119)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4dece5f0-ab6c-40ed-9ec6-0b1377d19e78"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee33d90b-2f70-4c9d-863d-6486b95280b8"}}}], "length": {"value": 0.0199779, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bd47d45f-500c-4c3d-8678-51a92d9023ea", "name": "l(r:p1rdm93-p1rdm94)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5151d03-c8b3-41f2-a2cd-743aa8ea0fea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4dece5f0-ab6c-40ed-9ec6-0b1377d19e78"}}}], "length": {"value": 0.0237669, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e1298125-2403-434a-b2db-9f772bc576f3", "name": "l(r:p1rdm93-p1rdt45lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e276abc-bb27-47e4-9de8-adaccbf964dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5151d03-c8b3-41f2-a2cd-743aa8ea0fea"}}}], "length": {"value": 0.0199888, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "96d5897f-f166-4bb2-8b66-3b7ba676cfe2", "name": "l(r:p1rdm95-p1rlv132)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a363b9b6-b80f-42cf-942e-17e723376ae6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41960437-e2e6-4746-89c2-81c81602ca1b"}}}], "length": {"value": 0.027088, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "79f574f4-b9a5-43f9-ab40-01e7afbc43b6", "name": "l(r:p1rdm95-p1rdt45lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e276abc-bb27-47e4-9de8-adaccbf964dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a363b9b6-b80f-42cf-942e-17e723376ae6"}}}], "length": {"value": 0.0399682, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "93d914a2-0ec3-414d-9502-25ee2a4943eb", "name": "l(r:p1rdm96-p1rlv78)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e93e7ed-6686-4fb2-8410-867f2cdbdab2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae76f058-b79a-4c0f-90be-f9cd7a02bcfc"}}}], "length": {"value": 0.032544800000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3e22d8ca-5f4b-48ed-afc3-1da29b5dce45", "name": "l(r:p1rdm97-p1rlv87)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdd576f2-a7e2-46eb-b2b0-818c4a97e694"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "46ee0e6c-daf7-4412-94a7-5332a6a97656"}}}], "length": {"value": 0.029464900000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e72d832f-a10c-4a41-bce6-db90e6a066d2", "name": "l(r:p1rdm96-p1rdm97)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e93e7ed-6686-4fb2-8410-867f2cdbdab2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdd576f2-a7e2-46eb-b2b0-818c4a97e694"}}}], "length": {"value": 0.0168832, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8cfe93c7-253e-4b6b-b392-aea42b09d08e", "name": "l(r:p1rdm96-p1rdt46lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aacdcb46-43e3-4147-ac25-3a9c1223e13a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e93e7ed-6686-4fb2-8410-867f2cdbdab2"}}}], "length": {"value": 0.018235, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "78991428-108e-4d6c-9398-41e4ca9a49db", "name": "l(r:p1rdm98-p1rlv138)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70024d6c-94dd-4367-aeec-92d4bc5eec04"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea9e5f8c-8477-403c-9d3a-911c4e5ab5c8"}}}], "length": {"value": 0.0236773, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c3c52273-2722-4a97-bd10-8e3dd59685c4", "name": "l(r:p1rdm98-p1rdt46lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aacdcb46-43e3-4147-ac25-3a9c1223e13a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70024d6c-94dd-4367-aeec-92d4bc5eec04"}}}], "length": {"value": 0.0547245, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d216af78-c172-4a19-a303-41195ec88d64", "name": "l(r:p1rdt47lv-p1rlv80)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f031530a-b3fc-4f8e-b0ac-139009d1256c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab7e1b4a-f8ec-4211-b7a0-d7f9057f576a"}}}], "length": {"value": 0.0117312, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "97d48ab3-ae67-4bb4-9933-c573d3b1b708", "name": "l(r:p1rdt47lv-p1rlv92)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f031530a-b3fc-4f8e-b0ac-139009d1256c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db8f484a-94d5-4d20-8ebf-6708b1601a0d"}}}], "length": {"value": 0.0191133, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "496ae067-3834-4768-96cc-4f91d6de96f4", "name": "l(r:p1rdt48lv-p1rlv81)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f1790fe-a399-46e3-b9e3-5979837777ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef92e40c-fe3c-4f7f-b844-884e1079e491"}}}], "length": {"value": 0.0151262, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "42788906-ee7c-4cb5-8863-6cdb7c3c583f", "name": "l(r:p1rdt48lv-p1rlv120)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f1790fe-a399-46e3-b9e3-5979837777ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a02925cd-7c5b-475f-9e91-30d639bb3c33"}}}], "length": {"value": 0.018014, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e6aee435-bc57-4b28-884d-c7734e4c64c1", "name": "l(r:p1rdm103-p1rlv122)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd7286c0-4c57-435f-bed2-fd9a927de8cc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b02739e-d082-4c54-8deb-8ccc83ab82ab"}}}], "length": {"value": 0.0117766, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "80537724-8dad-4e90-9c0f-536cfeb4f9aa", "name": "l(r:p1rdm103-p1rdt48lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f1790fe-a399-46e3-b9e3-5979837777ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd7286c0-4c57-435f-bed2-fd9a927de8cc"}}}], "length": {"value": 0.0197485, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0cac18f1-d0e4-45c0-9221-b52524ca2f6d", "name": "l(r:p1rdt49lv-p1rlv146)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e5bcc7e-f35c-4bbf-a7ff-a82817488b11"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da2538bd-189b-4699-823b-ed459d94b422"}}}], "length": {"value": 0.0323291, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "13eb61ae-13e2-4fcc-a1a7-33a49f742fef", "name": "l(r:p1rdm104-p1rlv82)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2409ced2-7817-40af-951f-33d725e9d75a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3ddd704-2530-4392-8e9e-06e047b12f41"}}}], "length": {"value": 0.018038, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0bf98212-8412-4b8c-8960-9f693eb62909", "name": "l(r:p1rdm104-p1rdt49lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e5bcc7e-f35c-4bbf-a7ff-a82817488b11"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2409ced2-7817-40af-951f-33d725e9d75a"}}}], "length": {"value": 0.0322986, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8527ab91-ca01-4884-958f-9bf6cadfb78d", "name": "l(r:p1rdm105-p1rlv107)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8385921-c183-4c26-bc99-bf5f0364c18b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "096e92a6-ea34-435e-a059-57d5234e1654"}}}], "length": {"value": 0.0143529, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "477a74e8-32b9-4d2f-8c62-4a8e287e6159", "name": "l(r:p1rdm105-p1rdt49lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e5bcc7e-f35c-4bbf-a7ff-a82817488b11"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8385921-c183-4c26-bc99-bf5f0364c18b"}}}], "length": {"value": 0.025904, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "eeb8dff2-6d0f-4edd-ab69-3e388cb798e4", "name": "l(r:p1rdt50lv-p1rlv127)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8208c617-caa9-46a5-b28a-8a5b0d9898a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ae7b1fe-08c4-4848-867e-e2426a325a99"}}}], "length": {"value": 0.0188957, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b4256583-e043-485c-b1d9-d6895fd573e8", "name": "l(r:p1rdm107-p1rlv83)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7948c980-abf7-4357-9ff8-4be9122a3167"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24c3e8d8-1520-4a05-84af-a70da6140b4d"}}}], "length": {"value": 0.02164, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "312ba1b5-d276-4196-b974-e562abef042c", "name": "l(r:p1rdm107-p1rlv123)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7948c980-abf7-4357-9ff8-4be9122a3167"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6184fe8d-ae60-426a-8c0c-a3cc56c5b67e"}}}], "length": {"value": 0.0223678, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ee3cd3d5-6ad3-46f8-be26-c622fe63b8e3", "name": "l(r:p1rdm107-p1rdt50lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8208c617-caa9-46a5-b28a-8a5b0d9898a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7948c980-abf7-4357-9ff8-4be9122a3167"}}}], "length": {"value": 0.01639, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d826c2fb-edda-469a-8669-c708580b5496", "name": "l(r:p1rdm110-p1rlv135)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2deeb6a-3ea7-44d9-9ee0-b013733dadc4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbdefe7a-517b-495b-88b8-dcf15a9429ff"}}}], "length": {"value": 0.0127473, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b029d869-0f98-49a8-ae56-7d0d5762a52f", "name": "l(r:p1rdm110-p1rdt50lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8208c617-caa9-46a5-b28a-8a5b0d9898a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2deeb6a-3ea7-44d9-9ee0-b013733dadc4"}}}], "length": {"value": 0.0164, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "205b7f88-30e3-477c-8222-63e49c3e5d9f", "name": "l(r:p1rdt51lv-p1rlv84)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09d7f030-a9b4-4705-82af-6cf140ba64d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "55e7538f-4bde-4810-a237-ac0cad7ba805"}}}], "length": {"value": 0.0456569, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "239e52d2-6f1c-4541-b593-743f536d2902", "name": "l(r:p1rdt51lv-p1rlv93)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09d7f030-a9b4-4705-82af-6cf140ba64d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0060c029-188f-4725-a935-8d0d9cc892f7"}}}], "length": {"value": 0.0305916, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a60d8329-112d-4656-b827-353773776f11", "name": "l(r:p1rdm113-p1rlv85)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5dd2d9f-42d5-48c4-b1e1-34ae6aa555df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcc52dd9-bacb-4e49-a057-d3747f89a7f7"}}}], "length": {"value": 0.0311927, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "5f3de303-599b-4841-99bd-cbb5d215b96a", "name": "l(r:p1rdm114-p1rlv91)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f42789f3-35c3-4d0d-adda-2044adce92c0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a1f01bc-d1f1-4d92-b1e2-1f8223624c52"}}}], "length": {"value": 0.0125623, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d83ba6fd-6457-4dda-a12d-dd5e09239ede", "name": "l(r:p1rdm113-p1rdm114)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5dd2d9f-42d5-48c4-b1e1-34ae6aa555df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f42789f3-35c3-4d0d-adda-2044adce92c0"}}}], "length": {"value": 0.0299732, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4d3d0323-36de-40d0-8acd-e15ce914b8e3", "name": "l(r:p1rdm113-p1rdt52lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c70a7331-8c41-4370-b053-3eae432d52ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5dd2d9f-42d5-48c4-b1e1-34ae6aa555df"}}}], "length": {"value": 0.0479351, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ebaf4901-4748-4e10-9bb6-f80772e1827b", "name": "l(r:p1rdm115-p1rlv94)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2d46cd2-9caf-47a7-b134-a29fccd91b9c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db2d4080-1f43-47a3-9f3a-e25d1e4f5076"}}}], "length": {"value": 0.0260186, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "55a80fa5-3bf1-418a-ad5c-7afa1fdf1e6c", "name": "l(r:p1rdm115-p1rlv103)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2d46cd2-9caf-47a7-b134-a29fccd91b9c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85afc796-3fe5-4027-b84e-10d502124636"}}}], "length": {"value": 0.0244121, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c44afe7e-8438-4d2c-a1e6-382731061903", "name": "l(r:p1rdm115-p1rlv144)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2d46cd2-9caf-47a7-b134-a29fccd91b9c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b7dbf54-f6bc-4e20-b2f3-8c63a44dd993"}}}], "length": {"value": 0.0176755, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f0aa2a13-e0c6-4712-8ce1-2b96b3454699", "name": "l(r:p1rdm116-p1rlv98)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0d6e82b-cba7-4c7e-8715-d73c3530bad7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "82f19d5c-0941-411d-8baa-3ba029471dae"}}}], "length": {"value": 0.0189352, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b9299fb3-8eb3-4d8c-beab-ef5d8bb3bd1a", "name": "l(r:p1rdm116-p1rlv136)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0d6e82b-cba7-4c7e-8715-d73c3530bad7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b45d086e-8e0d-42f4-a8ec-6d3a9579a96b"}}}], "length": {"value": 0.0258527, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "50eab12d-7e60-4f3e-86f8-77d7b63e1519", "name": "l(r:p1rdm115-p1rdm116)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2d46cd2-9caf-47a7-b134-a29fccd91b9c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0d6e82b-cba7-4c7e-8715-d73c3530bad7"}}}], "length": {"value": 0.012779, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1a90bcc3-121b-46ea-94ea-72690102cce8", "name": "l(r:p1rdm115-p1rdt52lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c70a7331-8c41-4370-b053-3eae432d52ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2d46cd2-9caf-47a7-b134-a29fccd91b9c"}}}], "length": {"value": 0.0312606, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a96a0a61-3593-4283-b799-abda634a973a", "name": "l(r:p1rdm122-p1rlv125)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "329f78a6-af13-4ceb-bc87-4660d497c22e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3367cc2-b096-4cfb-ae71-038eb9e06b46"}}}], "length": {"value": 0.027476800000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6105b98f-5c04-4aaf-8f0c-a630b2e674a6", "name": "l(r:p1rdm122-p1rlv148)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "329f78a6-af13-4ceb-bc87-4660d497c22e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa8af0a4-4d55-41e4-83d1-4fe349920e38"}}}], "length": {"value": 0.0149493, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "34c5ce67-2b3c-449c-a145-88ccef71510b", "name": "l(r:p1rdm121-p1rlv111)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d595142-3854-4152-b64a-6cda8396a523"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66748ae6-b6ef-4228-bb0f-f9a121f0e1a3"}}}], "length": {"value": 0.03370220000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f9ab571c-93e7-490b-be92-60d27d05330f", "name": "l(r:p1rdm123-p1rlv131)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2e27276-ea6c-40a3-92d3-4648ec9d235d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "499fb461-ccb6-436a-8078-eec9beffb4a9"}}}], "length": {"value": 0.0223731, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f08beed6-f030-42b2-b689-6fd6dffe7d03", "name": "l(r:p1rdm121-p1rdm123)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d595142-3854-4152-b64a-6cda8396a523"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2e27276-ea6c-40a3-92d3-4648ec9d235d"}}}], "length": {"value": 0.013548500000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6733f40f-da94-451d-ba9c-afc9bfd279e4", "name": "l(r:p1rdm121-p1rdm122)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "329f78a6-af13-4ceb-bc87-4660d497c22e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d595142-3854-4152-b64a-6cda8396a523"}}}], "length": {"value": 0.0118562, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "50295530-0eb2-46e9-b8d5-a2010ea2855a", "name": "l(r:p1rdm122-p1rdt53lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2536a0eb-a35c-40d4-9773-b78379e7481a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "329f78a6-af13-4ceb-bc87-4660d497c22e"}}}], "length": {"value": 0.0118562, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2688b58c-4fd5-467c-9a5a-8962e7d77466", "name": "l(r:p1rdm124-p1rlv141)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9f62740-f47f-4c97-bae7-4380fe83fcbc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb69a6a9-3eaf-4fc3-82be-0eec77455a82"}}}], "length": {"value": 0.0132542, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f0af7522-e5a1-45b8-a7fa-b575d9c6c63d", "name": "l(r:p1rdm120-p1rlv89)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1071344-55a0-4684-9fbf-5729ec1f21c2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24d75e9a-0249-48ca-ad10-32738bb6a519"}}}], "length": {"value": 0.010837, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c06a98a5-6584-47f6-80ff-d3e030eb948f", "name": "l(r:p1rdm120-p1rdm124)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9f62740-f47f-4c97-bae7-4380fe83fcbc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1071344-55a0-4684-9fbf-5729ec1f21c2"}}}], "length": {"value": 0.0349944, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7714abfb-4610-4b7d-9630-1be09cdc28fb", "name": "l(r:p1rdm124-p1rdt53lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2536a0eb-a35c-40d4-9773-b78379e7481a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9f62740-f47f-4c97-bae7-4380fe83fcbc"}}}], "length": {"value": 0.0174998, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e080f5fa-042f-4074-8eea-968559086793", "name": "l(r:p1rdt54lv-p1rlv90)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57889d14-4aac-4aee-a9e2-677a047e8054"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e06b2ac7-926e-4caf-afac-386910d4ea5e"}}}], "length": {"value": 0.05434540000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2e600f0e-d9b7-4e78-961b-8a6d0b046494", "name": "l(r:p1rdt54lv-p1rlv105)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57889d14-4aac-4aee-a9e2-677a047e8054"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fe82ede-430d-454d-b9d0-e212d0621ea1"}}}], "length": {"value": 0.0270168, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "26085e14-749e-4f2b-a8c0-be910144cf4c", "name": "l(r:p1rdt56lv-p1rlv96)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85ad3bf0-7e82-4e32-8106-faddcf725bdf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31508077-f731-47cb-94a9-869d7910e406"}}}], "length": {"value": 0.0243138, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d926d302-a341-4969-9971-0260425c8bef", "name": "l(r:p1rdm131-p1rlv804)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a60b127d-0530-495e-b3b9-2ebabf070fa1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a11ba246-99d9-4cf5-a557-bec53c75e6fb"}}}], "length": {"value": 0.0159541, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "23ec8047-b4d9-4836-9ad5-57087153b0b5", "name": "l(r:p1rdm131-p1rdt56lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85ad3bf0-7e82-4e32-8106-faddcf725bdf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a60b127d-0530-495e-b3b9-2ebabf070fa1"}}}], "length": {"value": 0.09807820000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3f894fd6-ef69-4853-be69-9ad20f68588d", "name": "l(r:p1rdm133-p1rlv99)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bf5bf18-363d-4f4e-bf10-9ffc601c0f30"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc4a448a-c6cb-4714-b8e6-b75bc6bc219c"}}}], "length": {"value": 0.0124594, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2680f81d-187f-458a-87c9-3e3af28acdaa", "name": "l(r:p1rdm133-p1rdt58lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3367c40-9f47-42d9-b627-bc502b170f2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bf5bf18-363d-4f4e-bf10-9ffc601c0f30"}}}], "length": {"value": 0.0166928, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "79b3a5aa-4572-4e8e-81ec-f62100bf8f85", "name": "l(r:p1rdm134-p1rlv101)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32e76273-c930-4506-9610-8cbfca04af67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48d1be49-5aca-4e18-8b85-2a1274b3f26d"}}}], "length": {"value": 0.027751, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e553c362-e091-4433-818b-930c420bf0a0", "name": "l(r:p1rdm134-p1rdt58lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3367c40-9f47-42d9-b627-bc502b170f2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32e76273-c930-4506-9610-8cbfca04af67"}}}], "length": {"value": 0.0166928, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "aab15890-22e5-493d-8c40-2a9eb3680b9c", "name": "l(r:p1rdm135-p1rlv100)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7b11b31-78f1-41fa-b511-df76daad0efc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62a0d673-eaba-4032-9038-8095e2d53999"}}}], "length": {"value": 0.0216228, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "045e775e-d108-4d2d-bff1-fd70db392191", "name": "l(r:p1rdm135-p1rdt59lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8aca9934-9439-4ce6-9ee3-475980324054"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7b11b31-78f1-41fa-b511-df76daad0efc"}}}], "length": {"value": 0.01639, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "299c7e4a-01dd-4183-8922-cd3a145251f0", "name": "l(r:p1rdm136-p1rlv121)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a415176a-ddab-47a0-9ce7-54c53c4c0f11"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0dbaab50-3abc-4207-82dc-5fcc5be68aad"}}}], "length": {"value": 0.024910800000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "def46ab3-205a-44d1-8334-ca8d8e6177c4", "name": "l(r:p1rdm136-p1rdt59lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8aca9934-9439-4ce6-9ee3-475980324054"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a415176a-ddab-47a0-9ce7-54c53c4c0f11"}}}], "length": {"value": 0.018122, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0a52364f-f121-431c-a2b3-2b5afc7a1064", "name": "l(r:p1rdt60lv-p1rlv102)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2517cea-05d3-4b7f-b9fc-0df0fde81235"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06a432e3-dd37-4c52-b954-6652bb529c8e"}}}], "length": {"value": 0.027151, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "45d4171e-dfd6-4632-a1f4-1631c7bb39fb", "name": "l(r:p1rdm138-p1rlv104)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e53344e0-e328-4acd-b159-e1f8cc246996"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c76c5b8f-1994-470c-a024-b97c73b9bb41"}}}], "length": {"value": 0.024191, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fd16c16e-bcb3-49ac-b2c8-5b3f035f1a47", "name": "l(r:p1rdm138-p1rdt61lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70f11a44-826f-45b8-9dc3-0f51ce6c9733"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e53344e0-e328-4acd-b159-e1f8cc246996"}}}], "length": {"value": 0.031133800000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8f90a935-dde4-4055-911b-e8879ea22ef8", "name": "l(r:p1rdm139-p1rlv124)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "022bda10-6b1a-408b-a231-adb63e189d14"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e5ca78b-6151-4a35-8a04-1bab215f0f10"}}}], "length": {"value": 0.0139389, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ff500abb-a8c2-406e-b3f7-762556f3baf4", "name": "l(r:p1rdm139-p1rdt61lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70f11a44-826f-45b8-9dc3-0f51ce6c9733"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "022bda10-6b1a-408b-a231-adb63e189d14"}}}], "length": {"value": 0.04687960000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "229322ea-6622-4b66-b281-0c2279fd872b", "name": "l(r:p1rdt63lv-p1rlv109)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fac6d4e1-b14d-4973-9626-6a4bde2d2a42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c76fc99c-c160-4ed0-85dd-ec3da962bb24"}}}], "length": {"value": 0.0188407, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "29137b68-38a0-4299-9224-4de2da7e7ec2", "name": "l(r:p1rdt63lv-p1rlv112)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fac6d4e1-b14d-4973-9626-6a4bde2d2a42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25edc94b-a44b-4200-8cde-73941c2818b8"}}}], "length": {"value": 0.04148810000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "90fa423f-c3aa-41a3-b1ff-5e27be2447cf", "name": "l(r:p1rdm143-p1rlv139)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21b14d95-6634-4f0e-a380-d5e57328d825"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b515111-3455-471a-aba8-92c82624a195"}}}], "length": {"value": 0.0108102, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "34f808d1-99d2-4282-862a-0ada3cd93d88", "name": "l(r:p1rdm143-p1rdt63lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fac6d4e1-b14d-4973-9626-6a4bde2d2a42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21b14d95-6634-4f0e-a380-d5e57328d825"}}}], "length": {"value": 0.016739300000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4283d362-7320-4954-872c-29955cf66239", "name": "l(r:p1rdm145-p1rlv113)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09182ca9-8ea2-4d1c-9c3e-5850a77c1b66"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2756378a-0c67-47cf-969d-bdb9e55c8a4b"}}}], "length": {"value": 0.020074400000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "040ec575-fb08-4511-ad29-6f7f2a4d7af6", "name": "l(r:p1rdm145-p1rlv128)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09182ca9-8ea2-4d1c-9c3e-5850a77c1b66"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56bc8935-c658-424c-83d8-0d13bf8d292a"}}}], "length": {"value": 0.0115543, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c1b08193-75f8-4a5a-bf68-d42b893314b1", "name": "l(r:p1rdm145-p1rdt65lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ae9cb89-7cb8-48c6-a5bc-4178ee364ae8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09182ca9-8ea2-4d1c-9c3e-5850a77c1b66"}}}], "length": {"value": 0.0459314, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0091adf2-477d-4aec-bab4-b4f1d4f1e4bd", "name": "l(r:p1rdm147-p1rlv838)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "de7551d6-5168-440c-8fe2-9f17e0904c29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7ffe87d-4424-4495-83c1-6765d385207c"}}}], "length": {"value": 0.0255431, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8d2187a7-f961-459a-84c8-fd146db95437", "name": "l(r:p1rdm147-p1rdt65lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ae9cb89-7cb8-48c6-a5bc-4178ee364ae8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "de7551d6-5168-440c-8fe2-9f17e0904c29"}}}], "length": {"value": 0.0470531, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2ae9cae5-3620-485e-bc07-7fb5feee034e", "name": "l(r:p1rdt66lv-p1rlv114)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfb9fa3b-c758-4c2e-bc51-f297b1ed21bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7934cd3-dcd6-4b67-8206-8a3636b6f75d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "8024cb11-d099-42e8-a763-d30f1bb4a619", "name": "l(r:p1rdt68lv-p1rlv118)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd2d6296-a302-4027-9e5f-c24a56a1a1ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "247e37b3-d6d0-41d7-a6b3-ee29d415da50"}}}], "length": {"value": 0.059931, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "145aef75-cb5e-433d-8d5a-8361f88a52f2", "name": "l(r:p1rdt69lv-p1rlv129)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7057debb-bd4d-4156-a253-0f3a14cdd784"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6c42586-4f46-45c6-910f-90fca771cfd2"}}}], "length": {"value": 0.0182448, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "07a96d7b-4253-4b07-938f-5f40eb0597b4", "name": "l(r:p1rdt69lv-p1rlv140)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7057debb-bd4d-4156-a253-0f3a14cdd784"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47b7d9f8-ca72-4a77-af67-74ee561f7f10"}}}], "length": {"value": 0.0205388, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "326b2815-73fb-47a1-b2b2-e52a6009bae3", "name": "l(r:p1rdt70lv-p1rlv133)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02440066-bc62-4629-96c5-4b497827de5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31dc8280-eb14-4f87-85d7-8eae17013fe7"}}}], "length": {"value": 0.027257900000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0896fb8c-8a94-4a92-8427-e52dd8da6f11", "name": "l(r:p1rdm155-p1rlv134)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43d5d2c5-10f6-4e89-91fa-5186f269b659"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "425bdcfa-9753-4ef5-bb38-9e014ae779dc"}}}], "length": {"value": 0.0117214, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "67b0fa5c-c109-4dc4-a7e5-8a596918e2c5", "name": "l(r:p1rdm155-p1rdt71lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e71f106d-4b41-405f-bce9-3d06b336a554"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43d5d2c5-10f6-4e89-91fa-5186f269b659"}}}], "length": {"value": 0.024182, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "68303935-f043-4a5f-ae67-0cef20dd642e", "name": "l(r:p1rdm156-p1rlv145)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8357e543-eba0-4863-9d95-e34d84a3fae7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1704e67-dfa3-4a6b-a3f4-7ebba9d27537"}}}], "length": {"value": 0.014900100000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bfa069fa-7070-4e5b-b9aa-1521209b1000", "name": "l(r:p1rdm156-p1rdt71lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e71f106d-4b41-405f-bce9-3d06b336a554"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8357e543-eba0-4863-9d95-e34d84a3fae7"}}}], "length": {"value": 0.013317800000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5900d375-7f71-4fe1-a29a-4d36a9287091", "name": "l(r:p1rdt72lv-p1rlv147)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b59eeab-d997-4186-ab59-0424644d5aeb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "070d9a60-c6f2-424c-bd0f-66c52d349f0c"}}}], "length": {"value": 0.021214800000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "35f35705-9799-435b-ae55-94c357a8cb75", "name": "l(r:p1rdm158-p1rlv149)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35f3fd4d-f962-4e4e-89d8-8b41a07ff57d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "063e89ea-6dd0-404f-abfb-21686f3041ed"}}}], "length": {"value": 0.0223159, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "88271973-bd02-47cf-8ce6-9297ca915d33", "name": "l(r:p1rdm158-p1rdt73lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f027d15-df82-4989-93e5-a3b40c862b08"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35f3fd4d-f962-4e4e-89d8-8b41a07ff57d"}}}], "length": {"value": 0.0177535, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "94aed7aa-d694-4d27-ac2a-69f72d010664", "name": "l(r:p1rdm159-p1rlv167)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b8d2667-d52b-46b3-ace4-2ad2b4e3050e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5187e006-621e-4c15-9604-0272ae62887c"}}}], "length": {"value": 0.0172799, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3f4794ef-c7bb-47ed-ae29-ece483a30c44", "name": "l(r:p1rdm159-p1rdt73lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f027d15-df82-4989-93e5-a3b40c862b08"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b8d2667-d52b-46b3-ace4-2ad2b4e3050e"}}}], "length": {"value": 0.0177535, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9a4c7fc8-af6b-46fd-a354-08371ebfcf7e", "name": "l(r:p1rdm160-p1rlv150)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb4a799f-0e03-4ba6-b8ce-8f5e117fd2c2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b9979ec-4e43-4feb-a617-28191e9dd9d8"}}}], "length": {"value": 0.023161300000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d7a1bde2-f7a2-4d8d-8c90-3c65fbc01fba", "name": "l(r:p1rdm160-p1rdt74lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37880102-8a9c-4f7b-930a-b29a94241866"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb4a799f-0e03-4ba6-b8ce-8f5e117fd2c2"}}}], "length": {"value": 0.0168665, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4d2c8db5-28f9-42a7-b24f-191844d2df53", "name": "l(r:p1rdm161-p1rlv169)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "243cdb10-5012-48b5-809f-1952913bf655"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e326756-7ead-4099-a065-9f2de5693197"}}}], "length": {"value": 0.0219801, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "dfdccb19-3918-4a66-8ff9-42e75bc5e315", "name": "l(r:p1rdm161-p1rdt74lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37880102-8a9c-4f7b-930a-b29a94241866"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "243cdb10-5012-48b5-809f-1952913bf655"}}}], "length": {"value": 0.0168563, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "94875e3d-2424-4911-a398-14b27da184b9", "name": "l(r:p1rdt75lv-p1rlv151)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "699bbf24-59ba-4dba-8bd4-1cf04a7e6e47"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "345b5c48-cd35-418e-bc08-50c06f5dff09"}}}], "length": {"value": 0.0195504, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a9a39282-bd02-4e82-ad57-8abf21c4bad6", "name": "l(r:p1rdt76lv-p1rlv154)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ecf2223-f120-45b4-8aab-a36d60161aec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ccdfbc7-d3a6-4f74-ad32-25ff11a2e3b7"}}}], "length": {"value": 0.013038, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "84f9badb-2feb-4fc0-9f7b-2e8a011fde0b", "name": "l(r:p1rdm163-p1rlv153)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0bd295ef-2c38-4c6b-915a-73900e920b92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ebbe09dd-7560-4eff-9e32-803f14b4ce7c"}}}], "length": {"value": 0.0190604, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9844c82d-1619-481b-9355-a508b593d8f2", "name": "l(r:p1rdm163-p1rdt76lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ecf2223-f120-45b4-8aab-a36d60161aec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0bd295ef-2c38-4c6b-915a-73900e920b92"}}}], "length": {"value": 0.0157338, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "79b6b890-dc64-4ae0-82bd-de9ffbe2e0de", "name": "l(r:p1rdt77lv-p1rlv155)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3fd9bf7-ecdd-4dcb-966a-f426d5f2ee81"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2452d5af-5aba-4d4b-8cd9-27a95fe6b34d"}}}], "length": {"value": 0.023128200000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "98981286-258e-4c7d-9452-c6c98e2b96a6", "name": "l(r:p1rdm166-p1rlv156)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e110db24-1653-41b5-8496-821dfff05769"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f607e6b-9540-4845-9f0c-6c334eb0e807"}}}], "length": {"value": 0.0182012, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8f778f87-7e35-45ec-984f-a71d2d2552a6", "name": "l(r:p1rdm166-p1rdt78lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f0255b7-5369-40eb-8814-959b0d4245b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e110db24-1653-41b5-8496-821dfff05769"}}}], "length": {"value": 0.0187893, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "29265848-23e0-4b5f-bc67-c3a69b4ec89d", "name": "l(r:p1rdm167-p1rlv159)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c108a0c2-3093-4222-9547-5ac08f6d8a4a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0ae6c02-c29e-4bf9-b1d4-ecc7e37e7de2"}}}], "length": {"value": 0.0190142, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "70765cfe-bcf3-4651-aef0-ba765d84ad6a", "name": "l(r:p1rdm167-p1rdt78lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f0255b7-5369-40eb-8814-959b0d4245b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c108a0c2-3093-4222-9547-5ac08f6d8a4a"}}}], "length": {"value": 0.0238255, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "169b1bc9-8c2a-45ba-8108-75b0f300554e", "name": "l(r:p1rdt79lv-p1rlv164)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "624d03d5-ac53-4d58-ac86-62834fa13c61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61460072-bdc5-4a70-96fa-8ecfa71623f4"}}}], "length": {"value": 0.0140409, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "289216e0-4528-483f-acbb-e2f23d34c2c3", "name": "l(r:p1rdm168-p1rlv157)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "937989ee-4525-4394-b04f-37d77a2c910c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4355a473-4643-4f72-afe8-80ce773ca8e8"}}}], "length": {"value": 0.030818, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9f6477d9-5d1d-40fe-bb83-7e5a13092058", "name": "l(r:p1rdm168-p1rdt79lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "624d03d5-ac53-4d58-ac86-62834fa13c61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "937989ee-4525-4394-b04f-37d77a2c910c"}}}], "length": {"value": 0.012795000000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bb55e3ed-4ff8-4c38-8295-e3849dbb9b29", "name": "l(r:p1rdt80lv-p1rlv158)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ce05c72-facf-447f-ba14-cc2ef64579a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1cd7284-17fb-4382-a29d-dd8c5bfd7541"}}}], "length": {"value": 0.020056, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "09956226-9e3a-4f6d-9b35-faa0073f0f10", "name": "l(r:p1rdt81lv-p1rlv160)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b610625-09e3-4b72-a8fe-b0c36f5e137c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd2fae5a-e5dd-4ad4-8acc-422de00ae83e"}}}], "length": {"value": 0.0130169, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3eead181-f910-4fda-a540-6d31c233bba1", "name": "l(r:p1rdm172-p1rlv161)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2dad274-0d92-42fa-bf1e-a22af034211f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4842819e-3f17-47da-a8bf-c3402c3c00b7"}}}], "length": {"value": 0.0198598, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9f5ed50e-7216-4609-8db5-2605f3480b51", "name": "l(r:p1rdm172-p1rdt82lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9872669f-fd85-458a-8951-ec12965fb42b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2dad274-0d92-42fa-bf1e-a22af034211f"}}}], "length": {"value": 0.0233983, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0c3c8219-32ba-4305-986d-9d50b230171f", "name": "l(r:p1rdm173-p1rlv830)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44bdfec0-2d44-442d-b562-ac786c61a76a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b7538477-32ab-4db6-872d-83be7ec89fd9"}}}], "length": {"value": 0.016941, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2e07e867-c355-4586-876e-f4e62cece9b3", "name": "l(r:p1rdm173-p1rdt82lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9872669f-fd85-458a-8951-ec12965fb42b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44bdfec0-2d44-442d-b562-ac786c61a76a"}}}], "length": {"value": 0.0146175, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fb158784-8660-4b98-bebd-f836c1d4238d", "name": "l(r:p1rdt83lv-p1rlv163)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8dac1e07-5eb6-4945-a3d9-95b77310358d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "471bad88-4514-4b02-aa1a-1d2aaa15557f"}}}], "length": {"value": 0.021129600000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "92015457-1970-4062-ad0b-862739545707", "name": "l(r:p1rdm175-p1rlv165)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9de64e4-b140-4526-af3c-1f7ceaa687bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e7880c9-0932-4395-abf9-2274e400f280"}}}], "length": {"value": 0.0440542, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6b3be467-1489-413f-8884-dffbbb55fcb7", "name": "l(r:p1rdm175-p1rdt84lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdb8aaf1-0e21-42e0-a72d-666646561235"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9de64e4-b140-4526-af3c-1f7ceaa687bf"}}}], "length": {"value": 0.0128709, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "476a440b-2b65-427e-9160-56b6f9589207", "name": "l(r:p1rdm176-p1rlv166)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a6bf0b9-809d-48fb-b8bd-375df052b6cc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21d333f7-7426-4fa6-8ab2-c6118055ece1"}}}], "length": {"value": 0.0268124, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "77c0c35b-8ab2-45bb-9665-5cfb22ed9809", "name": "l(r:p1rdm176-p1rdt84lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdb8aaf1-0e21-42e0-a72d-666646561235"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a6bf0b9-809d-48fb-b8bd-375df052b6cc"}}}], "length": {"value": 0.014891, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a0cb5616-3b4a-4ef2-a418-0f34f92e5cde", "name": "l(r:p1rdt85lv-p1rlv168)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40f4034e-c735-419b-80cd-d729d75f4692"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "470fe3ed-5b24-438a-ba6d-cdd9f774e5ad"}}}], "length": {"value": 0.0181757, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "60e2ab6d-9475-4352-8dff-e83ebfd55fd3", "name": "l(r:p1rdt89lv-p1rlv174)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1186295-59ff-48a8-b31d-0f7cd40df1ab"}}}], "length": {"value": 0.059378900000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b34af2ca-a059-4e01-93f4-75562afe5d6a", "name": "l(r:p1rdt89lv-p1rlv175)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905e9287-bdb6-44e0-b0af-f59ab4ad4d8e"}}}], "length": {"value": 0.0220486, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7a00cf1f-e224-44c2-b130-ae181cbc684b", "name": "l(r:p1rdt89lv-p1rlv176)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "931c8cee-89fe-447d-8788-af1e5f9f8775"}}}], "length": {"value": 0.0331252, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "5cbc1082-febb-4953-b261-752d2c159e74", "name": "l(r:p1rdt89lv-p1rlv177)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "090d6084-5cc6-473d-99c0-a6309571d633"}}}], "length": {"value": 0.053761, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b428ecd9-3158-4565-9fd1-6e401d34c594", "name": "l(r:p1rdt89lv-p1rlv178)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9debf70-62f4-4870-ad8b-bffc4bc4ad3f"}}}], "length": {"value": 0.0259912, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "81c89f55-1e6d-495b-a730-bfcacf30aafe", "name": "l(r:p1rdt89lv-p1rlv179)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb03260b-d7d7-4779-ab2c-37c9a1e34d66"}}}], "length": {"value": 0.0485967, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0f9cbb19-2251-459a-8fef-5974f0e19e65", "name": "l(r:p1rdt150lv-p1rlv285)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d156fdde-5620-4a6f-b8c1-a3ab986fcc88"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d3a86df-2ac5-4959-b857-562795ce84ba"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "a7fc4ccd-23ad-4d23-9c5d-01f39107d778", "name": "l(r:p1rdt177lv-p1rlv337)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d64d858-a9f7-430f-890e-a456f8913c30"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57b88281-b728-4779-82b1-4cc9eb4b41b1"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "6fe53808-07ef-4c59-8888-4ecf921fbd4a", "name": "l(r:p1rdt178lv-p1rlv338)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3314fa8-a838-4028-abb5-043425fd0785"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6b2aba6-a289-4a50-a131-2064047d1341"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "c2486b9c-458d-4c7d-a30b-2005a6509c49", "name": "l(r:p1rdt180lv-p1rlv340)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3e633bc-311e-4698-a413-9c6cf09c42a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb4797d6-b46e-4058-8985-d9f4b660f0a7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "bd6ee48d-28b5-4315-aa01-18786c9521fd", "name": "l(r:p1rdt181lv-p1rlv341)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05401825-91f8-41f8-9204-ab5806458594"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54f0ea2c-3849-4ff0-ad8c-e3f65515d178"}}}], "length": {"value": 0.0184707, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1b31f96a-78eb-4c21-a342-8e9911075c8f", "name": "l(r:p1rdt181lv-p1rlv342)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05401825-91f8-41f8-9204-ab5806458594"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13754fdb-4039-49fb-b584-8437191dfb2b"}}}], "length": {"value": 0.0184707, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6268230d-7e2d-460a-a71c-f4728aeb6115", "name": "l(r:p1rdt182lv-p1rlv343)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db407ddd-fb81-4767-99e1-9aeab12fc770"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0197ef22-9f8f-48a9-84de-663a7ce22773"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b1a02585-8b94-4e80-b57f-1077bfeba63f", "name": "l(r:p1rdt209lv-p1rlv377)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4724ea16-dc31-48f8-98b8-b9a223e9a4bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e1ea241-5329-4db5-996a-df09a9c25687"}}}], "length": {"value": 0.0107399, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "956ab7d4-2958-436c-a13d-ffd2364dc552", "name": "l(r:p1rdt209lv-p1rlv379)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4724ea16-dc31-48f8-98b8-b9a223e9a4bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50225dcf-40bc-44b5-9dec-072ac5b2334e"}}}], "length": {"value": 0.0107399, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2f7cb6af-5e60-46b7-9658-4724b60445a0", "name": "l(r:p1rdt210lv-p1rlv378)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05f6a3bf-d465-4f16-8205-616d1f4dd465"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3ff63a0-bf3f-43b0-807c-935467b4fe46"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "cf7a4cd4-9ab0-4b90-838b-e3dc4f53c107", "name": "l(r:p1rdt211lv-p1rlv380)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1d5af6ce-9a4c-414a-bbd8-15d82f50cb57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ee07ef9-b7b0-4457-be1c-78e754dbcfc7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "d5ffdfd7-04b1-491f-96ab-1d221c5a2721", "name": "l(r:p1rdt233lv-p1rlv415)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "591461d4-20da-4165-a210-4dbaedd81016"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b54aae8-5a94-4e04-882f-748e1c5f1390"}}}], "length": {"value": 0.0211272, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0505f748-32fd-40ee-adcc-f8ae4f7aa5e0", "name": "l(r:p1rdt233lv-p1rlv416)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "591461d4-20da-4165-a210-4dbaedd81016"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99abc7dc-8e15-420f-9bc9-0e6229d4dab3"}}}], "length": {"value": 0.0170787, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3e94a0ef-755f-4c61-8339-9228a6a9a348", "name": "l(r:p1rdm434-p1rlv412)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "019c88af-413c-4331-84f7-923a1df0a303"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b33ed36-116b-4741-9374-6927bd537427"}}}], "length": {"value": 0.0284617, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c321be1c-7377-4681-bef4-1a0174a2eae3", "name": "l(r:p1rdm434-p1rdt233lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "591461d4-20da-4165-a210-4dbaedd81016"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "019c88af-413c-4331-84f7-923a1df0a303"}}}], "length": {"value": 0.0343908, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6be33d65-8fea-460c-a84a-a0e3f510cfd2", "name": "l(r:p1rdm437-p1rlv419)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3b3eb51-c011-4f2c-8a10-c43c9c86217b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7935b9c-b631-432c-a322-9beea73f1fc4"}}}], "length": {"value": 0.0215859, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "98182c6b-dfb8-473b-8d57-952c06f1388d", "name": "l(r:p1rdm438-p1rlv420)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a713d96-e13f-447e-ab9f-012af3e26afe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4d7ed8-5ddd-4127-87ab-eb3f48a580c2"}}}], "length": {"value": 0.0147074, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "befe0c14-01c2-4b06-a7f9-2a47fc69e8cb", "name": "l(r:p1rdm437-p1rdm438)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3b3eb51-c011-4f2c-8a10-c43c9c86217b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a713d96-e13f-447e-ab9f-012af3e26afe"}}}], "length": {"value": 0.0117282, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "578c6339-ef3b-4716-adb1-a9e5b3ed6b05", "name": "l(r:p1rdm437-p1rdt233lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "591461d4-20da-4165-a210-4dbaedd81016"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3b3eb51-c011-4f2c-8a10-c43c9c86217b"}}}], "length": {"value": 0.0343908, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "42624629-eac1-4745-adf2-53d1be42e2d3", "name": "l(r:p1rdm439-p1rlv413)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "adb2d039-e162-43f7-8498-1374581a75fc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8408ac87-a086-46bc-9d88-cca79e17dd62"}}}], "length": {"value": 0.015615700000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5b4cc8dc-fc2d-4cb2-a6bd-7786ab4a81a2", "name": "l(r:p1rdm439-p1rdt234lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e480f304-b192-4107-91e1-131d481657b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "adb2d039-e162-43f7-8498-1374581a75fc"}}}], "length": {"value": 0.0177624, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e091d378-1707-46e2-9007-81ca0fb1783d", "name": "l(r:p1rdm440-p1rlv417)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84570b2e-efeb-477e-be1c-43b9d2922fda"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49dbdd44-a36a-46b5-aef8-558ef7693315"}}}], "length": {"value": 0.0243364, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "808b2de4-c291-4a98-bf76-253fbf95aa27", "name": "l(r:p1rdm440-p1rdt234lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e480f304-b192-4107-91e1-131d481657b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84570b2e-efeb-477e-be1c-43b9d2922fda"}}}], "length": {"value": 0.0354523, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f7407667-b6d5-4229-a8a0-b06a8bc055e6", "name": "l(r:p1rdt235lv-p1rlv421)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d8a6708a-d098-4e02-aac6-4aba7fdc71a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12dcb168-1bfe-448b-8d9a-f5cb4c61aafe"}}}], "length": {"value": 0.015099000000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8b295164-05a6-4f11-95bb-179fa6784c17", "name": "l(r:p1rdt236lv-p1rlv422)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7dd709e3-c5ec-4a01-8297-11f4d1261c3a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa7bb51b-8ba8-4a05-872a-7f5ce084fe88"}}}], "length": {"value": 0.0221266, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8526a0f0-81c9-4b1e-b0fd-6ca440c0c355", "name": "l(r:p1rdt236lv-p1rlv423)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7dd709e3-c5ec-4a01-8297-11f4d1261c3a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c1e9680-f7de-497c-953a-54f4db2899e2"}}}], "length": {"value": 0.013832, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "85e410b3-3fd8-4adf-b912-606c69de0cc1", "name": "l(r:p1rdt237lv-p1rlv424)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b72726f3-250c-4d98-86bc-5120137bd0f1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1a91c8c-aabd-4fad-8306-908f186a5744"}}}], "length": {"value": 0.0173984, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "63a6ee4f-9a39-4d73-94c7-2011f40c3e2a", "name": "l(r:p1rdt237lv-p1rlv449)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b72726f3-250c-4d98-86bc-5120137bd0f1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "753035df-8705-48eb-92b3-c4bef603b66b"}}}], "length": {"value": 0.0173984, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7090fbe2-cb8c-4c09-b6fa-da9414b54b2b", "name": "l(r:p1rdt251lv-p1rlv439)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42dff28c-89e7-4b56-bf23-3dcdd3ca216f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f771660-4dad-43df-b38b-7da5f6180a25"}}}], "length": {"value": 0.0641388, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d8826333-a219-4797-a8d9-92cd616ce986", "name": "l(r:p1rdt251lv-p1rlv445)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42dff28c-89e7-4b56-bf23-3dcdd3ca216f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d665758-71e1-4478-b39d-671f78f623e5"}}}], "length": {"value": 0.05250030000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f668b2d1-629e-440a-bc89-69bb83227759", "name": "l(r:p1rdt251lv-p1rlv446)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42dff28c-89e7-4b56-bf23-3dcdd3ca216f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acce3105-f519-491c-921a-df1294795742"}}}], "length": {"value": 0.0829969, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "bba4004f-1129-4d09-95ca-69a606870bc4", "name": "l(r:p1rdt251lv-p1rlv447)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42dff28c-89e7-4b56-bf23-3dcdd3ca216f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "042873fa-10df-4de0-a040-ac429b8bf7d9"}}}], "length": {"value": 0.0834464, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3ec5458c-b354-433b-a8d4-78268d281508", "name": "l(r:p1rdt251lv-p1rlv448)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42dff28c-89e7-4b56-bf23-3dcdd3ca216f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bb83d65-630d-4f1d-8e3d-8937a5a05524"}}}], "length": {"value": 0.0573344, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ad0a49de-fc5d-4d28-b860-b1a01394e3bc", "name": "l(r:p1rdt253lv-p1rlv441)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "704fece3-3b83-4c0b-bcd1-d463b3cdaf6b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a778b00-482c-4b81-8213-f17202a105fa"}}}], "length": {"value": 0.0393745, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e5b3ae7c-65ec-457c-83b8-b09122a326b0", "name": "l(r:p1rdt253lv-p1rlv444)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "704fece3-3b83-4c0b-bcd1-d463b3cdaf6b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30f29674-3083-4da2-95e2-a1f11a7eb7f8"}}}], "length": {"value": 0.0393745, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "66809432-ac15-4760-9231-6d4f6bfb9cf9", "name": "l(r:p1rdt254lv-p1rlv442)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "655d8f44-aa2f-4548-a1ca-83fcce9fa7aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cd667a9-c0ef-49ce-b6ee-7e474d9ae761"}}}], "length": {"value": 0.0182025, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "51d246f9-90d4-4835-bc50-b80c39ceacd0", "name": "l(r:p1rdt254lv-p1rlv443)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "655d8f44-aa2f-4548-a1ca-83fcce9fa7aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2100c17-c0e6-47e9-87f8-72016b22dd4b"}}}], "length": {"value": 0.0182025, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d0823786-024b-4ce4-a47b-e9ad39c63732", "name": "l(r:p1rdt257lv-p1rlv452)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4c28500-44f7-47c6-b8a8-d1e3468494e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb46f1ae-0cdb-45d1-b389-639cdf345f8e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "f289f501-a893-432d-90a7-87d93c77ec10", "name": "l(r:p1rdt258lv-p1rlv453)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad9ffaef-f21b-43da-9f67-3a8271edb6bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6a8a3c7-5165-48b7-8233-30d3af045442"}}}], "length": {"value": 0.0230491, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5c20bbe4-9be1-430f-95f9-596fa613a6e9", "name": "l(r:p1rdt258lv-p1rlv456)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad9ffaef-f21b-43da-9f67-3a8271edb6bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85f0d94e-c096-4d53-ae05-f0dc59f73d02"}}}], "length": {"value": 0.0595648, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0246e7a2-f298-4214-816f-1f9560d5c268", "name": "l(r:p1rdt258lv-p1rlv460)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad9ffaef-f21b-43da-9f67-3a8271edb6bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76b212f9-2e27-4064-a2c5-079786afb1d1"}}}], "length": {"value": 0.0369882, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "647e9cbe-c03f-424e-a989-fff636f9df75", "name": "l(r:p1rdt259lv-p1rlv454)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6a0feb3-78c1-4d69-8d18-2a8c3abdcf54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3493b0ed-43a2-4602-a7ad-a817331c9d8e"}}}], "length": {"value": 0.007000180000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b2c6818b-63e4-4176-97f7-3725e51b766d", "name": "l(r:p1rdt259lv-p1rlv455)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6a0feb3-78c1-4d69-8d18-2a8c3abdcf54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "552153cc-f5be-42ee-9985-9361c2e7e2a1"}}}], "length": {"value": 0.007000180000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "802e828a-0585-47a2-b9f3-0de5df57c988", "name": "l(r:p1rdt260lv-p1rlv458)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d8d796d8-6750-4ca5-ae07-1b07331ce6ee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec66e302-748d-4300-ba65-719de0a906bb"}}}], "length": {"value": 0.0434176, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "46c807d5-43c5-4672-a3dd-a19e5d31c13a", "name": "l(r:p1rdt260lv-p1rlv461)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d8d796d8-6750-4ca5-ae07-1b07331ce6ee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76dd0f1b-4109-4707-a547-f0ab1b6e148f"}}}], "length": {"value": 0.092428, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "79a59573-c06e-4a75-b3f8-53d31d0db6c5", "name": "l(r:p1rdt261lv-p1rlv459)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fe4ec5b6-61fb-4b66-9e43-19d81af88966"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c112196-bcbc-41bc-99a9-f3657c335c7a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "33cd8402-3871-4cca-bc3e-debcfdedae9b", "name": "l(r:p1rdt262lv-p1rlv462)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30952601-1479-4770-9b77-9fe3465310b7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9176da24-7eb5-4b0b-99dd-886c3f974798"}}}], "length": {"value": 0.00892698, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c4e43b97-aaab-467e-ad1b-42d7037f358b", "name": "l(r:p1rdt262lv-p1rlv464)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30952601-1479-4770-9b77-9fe3465310b7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "895d0235-3ee6-4f06-9978-9d615d721ebd"}}}], "length": {"value": 0.00892698, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a2576b3e-d1e5-4d50-a45e-1bc57c336d52", "name": "l(r:p1rdt263lv-p1rlv463)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c7501f4-0394-4766-a3c5-b17fda7f3817"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff9d9cca-1878-478d-a190-b58c9098f13e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "ccb77c32-f2aa-4914-bb43-9d5e74ae182b", "name": "l(r:p1rdt270lv-p1rlv474)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d33a03d6-fddc-4e47-8018-cd7d290b30b0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e589527-d388-4364-87d2-2f4af1a14509"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "31239fc0-0cf9-4784-9c31-840b76d2fb9d", "name": "l(r:p1rdt275lv-p1rlv480)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6715c6a-6869-412a-8e59-e5c2eb03c56b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb55ec0b-b6f7-48a7-8dae-dda95fc34499"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "8efe139e-f094-4b94-bbd7-6baf1eb8bb49", "name": "l(r:p1rdt276lv-p1rlv481)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b478b4f8-8d5e-47b0-a56a-8b991dc8d944"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d9e77ad-42c6-4413-96e6-debfed3c442a"}}}], "length": {"value": 0.0246686, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3108cca4-7ce2-4e79-91c3-6164c8569336", "name": "l(r:p1rdt277lv-p1rlv482)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24486e15-ff1e-45b3-aa02-703263f04844"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d4b708f-cc15-4ee3-87e0-4d26fec02f1e"}}}], "length": {"value": 0.0705132, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "924709b2-b4ce-4ebf-aef2-ea121372a161", "name": "l(r:p1rdt278lv-p1rlv483)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8af5824-d5d7-4cba-98b7-d72993909f22"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d059a618-6f09-404b-b1a0-0e7aa0c55c45"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "7ed80917-269f-463c-95a8-142aa98b6c52", "name": "l(r:p1rdm508-p1rlv484)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d6856ee-d113-45ec-99e0-8a915a89a56c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fde62b60-c5f6-44d6-b2f2-211c21b02033"}}}], "length": {"value": 0.0863808, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "dc284c67-9c82-4d92-ba75-22c40eb1286b", "name": "l(r:p1rdm508-p1rdt279lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bf679fe-712f-4db6-9df9-debb29b7ee73"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d6856ee-d113-45ec-99e0-8a915a89a56c"}}}], "length": {"value": 0.0129614, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "060491fd-0236-4f17-87f0-4f05976cbc99", "name": "l(r:p1rdm509-p1rlv485)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c3bf9bd-d12a-47d7-b2e2-3f31f3a0419b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d2c379-7e19-46c4-8c6e-533fa9db7764"}}}], "length": {"value": 0.0942097, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "39ff8538-f941-481e-9b42-22bd4064b712", "name": "l(r:p1rdm509-p1rdt279lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bf679fe-712f-4db6-9df9-debb29b7ee73"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c3bf9bd-d12a-47d7-b2e2-3f31f3a0419b"}}}], "length": {"value": 0.0129614, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9f41c3d1-c279-430b-97c6-bf785447f250", "name": "l(r:p1rdt280lv-p1rlv486)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e4eafd2-0f68-4e2a-a62c-89cb877004d4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a54b2228-9e7d-4e6b-939d-ab2765454522"}}}], "length": {"value": 0.0500266, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "23cca4ef-3f22-42e7-8a89-81df492f80d6", "name": "l(r:p1rdt281lv-p1rlv487)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e01a56d-1bfc-4169-9c3e-1373f9dbeb38"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2d5799-907e-46fd-a389-120aea352775"}}}], "length": {"value": 0.0588997, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9e629ff1-629c-4692-b1b2-89b36d3232b8", "name": "l(r:p1rdt281lv-p1rlv523)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e01a56d-1bfc-4169-9c3e-1373f9dbeb38"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97c38794-7c60-4ff8-b09b-7503c9604409"}}}], "length": {"value": 0.0588997, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f9183960-d27e-48f4-ae96-51a4370514fa", "name": "l(r:p1rdt297lv-p1rlv524)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a8430e1-656f-4fe2-a11b-00adf429d75d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bef074be-aac4-4d82-a832-641729756802"}}}], "length": {"value": 0.0214257, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "67082ac6-4033-43de-8e8e-060172e68525", "name": "l(r:p1rdt297lv-p1rlv526)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a8430e1-656f-4fe2-a11b-00adf429d75d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ab8e220-faf9-4108-80f8-22d2fe326c3d"}}}], "length": {"value": 0.0214257, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "84650700-4442-4d15-838e-e27a38df0870", "name": "l(r:p1rdt298lv-p1rlv525)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33e93250-9c11-4650-9469-412129855857"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a42f8b99-82c6-4c90-81ea-6ccb38eacfab"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "7b449da2-8e87-4ccd-9f7a-16c7fec58d1b", "name": "l(r:p1rdt303lv-p1rlv531)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6353ab92-f66f-47d8-97ac-058cf030ff82"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32a1d9d7-31c7-4def-88d4-e4d41bd21572"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "e0344bf6-1f0f-4397-9dfd-b63e20f8de7e", "name": "l(r:p1rdt304lv-p1rlv532)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a22ac71-bf3a-4016-86ce-fb25f471be5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1362feeb-2e2c-4dd1-9f49-239c952c6120"}}}], "length": {"value": 0.00939374, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a06c0184-9460-4a48-a932-28ad6fdc65df", "name": "l(r:p1rdt304lv-p1rlv533)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a22ac71-bf3a-4016-86ce-fb25f471be5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f79bc5f-375f-4ecd-b828-eb7b137d7cab"}}}], "length": {"value": 0.00939374, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8ba5afa0-cb40-49c4-9876-5b535d676651", "name": "l(r:p1rdt305lv-p1rlv534)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90948977-fe1a-43b3-a8a4-86c080ae4906"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0eb7074c-0745-4089-9329-aa3495f9b460"}}}], "length": {"value": 0.0332146, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "59645c30-0818-4298-96b3-c2e407a38c87", "name": "l(r:p1rdt305lv-p1rlv535)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90948977-fe1a-43b3-a8a4-86c080ae4906"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9cc91945-564c-4ace-bb53-77150b107b41"}}}], "length": {"value": 0.0280899, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f0cacb07-6f88-4b14-83a4-b12237b908e0", "name": "l(r:p1rdt305lv-p1rlv536)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90948977-fe1a-43b3-a8a4-86c080ae4906"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2ea78a8-b9c5-4760-b153-51b45565069e"}}}], "length": {"value": 0.0133525, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cce21752-5938-47bf-94e3-7a78fc6ba8c6", "name": "l(r:p1rdt306lv-p1rlv537)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53eba878-66fa-4d30-8af4-1f583abe5f16"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9f2dfc9e-0b72-4465-b46a-d4e2a7a08f64"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "7f8caa28-d1d5-4677-b1a8-caeaa8438cd5", "name": "l(r:p1rdt335lv-p1rlv588)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8e448ea-e66d-4e16-80c0-8e742d7cac55"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75628d41-a82d-4425-8aa2-9f377c771a4c"}}}], "length": {"value": 0.0252117, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a90371fa-16c1-4478-aa97-5e4dcfe53c31", "name": "l(r:p1rdt335lv-p1rlv589)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8e448ea-e66d-4e16-80c0-8e742d7cac55"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a1c60be-f1a1-48d6-b396-4cca6d8c4e62"}}}], "length": {"value": 0.0305453, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d3cd2429-6120-47a3-8205-e4b92179c8d4", "name": "l(r:p1rdt335lv-p1rlv590)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8e448ea-e66d-4e16-80c0-8e742d7cac55"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81ce208e-7244-418a-9867-b55b95ba0716"}}}], "length": {"value": 0.0192501, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8e534474-8d24-44b0-9a73-58eba8f2be88", "name": "l(r:p1rdt374lv-p1rlv657)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35993388-185f-4d1d-9dcb-16eb7556728f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e58890e-e6ce-4dda-91c0-5ccfdb5c420d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "d9844c82-b169-457d-9bc1-326623b23d77", "name": "l(r:p1rdt376lv-p1rlv660)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d354e81e-b007-4bbe-b1db-50d7afacd0e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15751ee2-6783-472f-ad57-ec978234fec4"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b54298a1-451c-4e04-b0a2-2a3ce8e8d748", "name": "l(r:p1rdt383lv-p1rlv672)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8569c197-174f-46ef-96c2-e0c674d7b046"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb25bf05-ce7f-405a-8c17-fd166748f7d3"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "6b21aab7-acec-4cf4-ad90-947d2d65d55b", "name": "l(r:p1rdt384lv-p1rlv673)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c56b4839-f007-4c9b-93a7-9147399f983f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31d3267c-7020-4660-9a0b-49cd9d94a5d0"}}}], "length": {"value": 0.0823342, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "05b78e9e-8d95-4a3a-8417-ca2d7471d413", "name": "l(r:p1rdt385lv-p1rlv674)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "579c3e97-d1dc-4306-91e6-4cbbed29f882"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "449992d6-a91b-40ea-9792-5166a5f2c849"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "13c5de65-ecbe-46fc-b13c-9b0ae93f362d", "name": "l(r:p1rdt414lv-p1rlv716)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29a78735-964b-4381-bea0-01e5b1b79be9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "93069f0f-fce7-47cd-b7b3-77e861f59573"}}}], "length": {"value": 0.0271185, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7aa72c83-7926-479e-9241-1847dffc0378", "name": "l(r:p1rdt414lv-p1rlv726)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29a78735-964b-4381-bea0-01e5b1b79be9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fdcbc55-681f-4fe5-8142-4945b25f6fef"}}}], "length": {"value": 0.0271185, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f433fa72-7ae0-4813-aec1-c749feeef425", "name": "l(r:p1rdt415lv-p1rlv717)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "789d55de-619d-43cd-b056-ebe1be4c2dea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd8fd159-f747-4ee4-a426-787f4eef4b42"}}}], "length": {"value": 0.0174256, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "40648953-ee06-4844-ac24-ebe40af874cb", "name": "l(r:p1rdt415lv-p1rlv724)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "789d55de-619d-43cd-b056-ebe1be4c2dea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3658479-7369-4bd9-be54-e7768c93a808"}}}], "length": {"value": 0.0174256, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "38efc7d5-3134-4ecb-a601-e7bab591df93", "name": "l(r:p1rdt416lv-p1rlv718)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473f5822-3412-4f3d-836e-f62314efa5b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4a1453b-98a3-4c2d-8ac2-c8b2ab1bfa4f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "42acdb9f-2a40-47c7-9aba-003a71207202", "name": "l(r:p1rdt417lv-p1rlv719)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98bb09be-6506-49e8-8fd8-1a01d6861162"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3153167-8b4c-40e4-abb7-3bdef86950c3"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "a06652f1-5337-439b-bde4-2b0916c1d9af", "name": "l(r:p1rdt418lv-p1rlv720)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e189aaf-7650-49b4-83dd-94a29111aca2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdbc11b7-5abf-4ff8-8d26-53faf4b1f3f5"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "c090ab4d-ac69-4ffb-8288-8e0f550fad74", "name": "l(r:p1rdt419lv-p1rlv721)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d9603d6-5e5e-4cc0-aa86-1bdb80f7e1cf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf12b67c-4df5-4dcb-a2e2-6ae2d0f82e65"}}}], "length": {"value": 0.08840930000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c9d83670-5d7e-4b3e-907b-e3d7877eccf2", "name": "l(r:p1rdt419lv-p1rlv723)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d9603d6-5e5e-4cc0-aa86-1bdb80f7e1cf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7551be44-a4ca-4edb-b823-6495d163201e"}}}], "length": {"value": 0.0583611, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e16c8db8-7dcb-4a01-9073-23a5a1d29c5f", "name": "l(r:p1rdt419lv-p1rlv725)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d9603d6-5e5e-4cc0-aa86-1bdb80f7e1cf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2bcbabc-a7fc-4230-8ec1-b6050af9cf58"}}}], "length": {"value": 0.0308381, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b986d57f-f8a8-4cd7-a6ec-334c76f99e58", "name": "l(r:p1rdt420lv-p1rlv722)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51673983-9230-421b-8501-bf71601b1b13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b7c6c65-e18c-4e79-b419-8894deb0d345"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "270edca9-1e67-412f-8e69-5ffb1e583c7d", "name": "l(r:p1rdt438lv-p1rlv749)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41f19802-32ca-4afc-8418-fe93e3ced1bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80983704-a98f-46dc-a09f-700bd7df1a29"}}}], "length": {"value": 0.0289764, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "538e127f-786f-4818-89c8-a58995828ae0", "name": "l(r:p1rdt438lv-p1rlv756)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41f19802-32ca-4afc-8418-fe93e3ced1bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3c3b0fb-5a5d-439e-a350-b97ba0df41a0"}}}], "length": {"value": 0.0289764, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f81dbe0e-d0d1-46b8-be6d-f9a7a1fc6ef9", "name": "l(r:p1rdt445lv-p1rlv764)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc7e7e51-f849-4bf4-b720-462daeb21932"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e368704b-6c4b-4afb-a577-4b0d7a96dd65"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "2f183098-d22d-473c-bc33-af8fab5902e3", "name": "l(r:p1rdt446lv-p1rlv766)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0727e1f5-f2ca-4e19-9dc3-89e185002e52"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07381934-8e9b-4447-a330-e8af484331f1"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "a5bb6545-64ef-40da-93ad-c0c9ab4b7840", "name": "l(r:p1rdt452lv-p1rlv786)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44f86829-17fc-4e83-b2a5-705454293161"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180adab2-e49b-42e9-9aeb-42be0a7686c5"}}}], "length": {"value": 0.0235153, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "225bdb8e-1f49-441f-8070-f7ca28084a18", "name": "l(r:p1rdm812-p1rlv775)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b4fed6c4-6907-4601-9671-6f83d582dc45"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d00977fb-8d2a-44ca-aa9e-034894d6e280"}}}], "length": {"value": 0.033048600000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "46b762a3-e999-4dbf-9c4f-a1df60636b0d", "name": "l(r:p1rdm812-p1rdt452lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44f86829-17fc-4e83-b2a5-705454293161"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b4fed6c4-6907-4601-9671-6f83d582dc45"}}}], "length": {"value": 0.0176265, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f95d010c-9470-489a-a425-a70c0d0e7256", "name": "l(r:p1rdm814-p1rlv776)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "090024f2-1724-4789-96da-174d1f5e65ec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c5b1f75-47c0-45c3-9ef3-f97a445b242e"}}}], "length": {"value": 0.0217688, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "551a73e5-acdd-437b-a6cc-6aed76529d23", "name": "l(r:p1rdm814-p1rdt453lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d58e1471-844f-46ef-9d9a-43753b1dee25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "090024f2-1724-4789-96da-174d1f5e65ec"}}}], "length": {"value": 0.0176166, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5a95a755-f19a-4c73-a19d-d006865b8bc0", "name": "l(r:p1rdm815-p1rlv819)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ecd0e9ae-cbf4-4435-8a57-ad23e3e037b4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "def7e507-cb62-42f5-8451-b8a742ef4eb2"}}}], "length": {"value": 0.022596800000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cfc97475-b1af-4388-ad2a-4ce25855b710", "name": "l(r:p1rdm815-p1rdt453lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d58e1471-844f-46ef-9d9a-43753b1dee25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ecd0e9ae-cbf4-4435-8a57-ad23e3e037b4"}}}], "length": {"value": 0.0167209, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "316d6767-840f-4299-b109-2097e8d276be", "name": "l(r:p1rdm816-p1rlv777)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2e41779-98fa-453d-b4df-10a5dd61a4b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fb1fca8-7985-4356-a8de-7433fef7a454"}}}], "length": {"value": 0.02155, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f75a9d71-e1a4-402d-bef5-4d848ec31d32", "name": "l(r:p1rdm816-p1rdt454lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b3e7941-9bdd-48f9-a4a5-a553da9bbb57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2e41779-98fa-453d-b4df-10a5dd61a4b5"}}}], "length": {"value": 0.0516187, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d259a7e7-8125-4187-bd47-e94dac2aaab6", "name": "l(r:p1rdm817-p1rlv789)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "87e4ddc3-ccc3-48af-bc35-d7d85f324ee7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9ce2439-fcc7-4965-81ee-f875db83b003"}}}], "length": {"value": 0.0112431, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "61eacf7d-42ae-4dc6-93af-6e874d82465b", "name": "l(r:p1rdm817-p1rdt454lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b3e7941-9bdd-48f9-a4a5-a553da9bbb57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "87e4ddc3-ccc3-48af-bc35-d7d85f324ee7"}}}], "length": {"value": 0.034455, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4b038cb4-9d4c-4388-b73a-07e32d9bdeac", "name": "l(r:p1rdm818-p1rlv800)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf188897-9db5-4ff4-8c5b-5932a8a794cf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3126c61-9602-45cf-8d57-27d26c14ca7e"}}}], "length": {"value": 0.0215285, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ac12c3ae-f77a-49ba-9a39-1cb0876944f4", "name": "l(r:p1rdm818-p1rdt454lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b3e7941-9bdd-48f9-a4a5-a553da9bbb57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf188897-9db5-4ff4-8c5b-5932a8a794cf"}}}], "length": {"value": 0.0352686, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6f93c84f-0710-47ab-a637-536624b07499", "name": "l(r:p1rdm819-p1rlv778)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b757a90a-ade8-486f-90f1-e7c5e13708ba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80d58665-ee8a-4f4e-a906-dc15aa3d8c6f"}}}], "length": {"value": 0.0239474, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8371aa9a-7c91-415a-8947-852337c10539", "name": "l(r:p1rdm819-p1rdt455lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53b40b3c-db5a-4fa0-bedb-f293c6eac473"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b757a90a-ade8-486f-90f1-e7c5e13708ba"}}}], "length": {"value": 0.0220829, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "56703918-b9f0-445c-923f-0b94682269a1", "name": "l(r:p1rdm820-p1rlv787)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea28f170-6bf0-47f7-a089-8375dff2ad4a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0089ee3-0cb4-434c-adc4-c91a8441ef0a"}}}], "length": {"value": 0.0195656, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "36bacdd9-ce23-4cee-9360-b33171a5e6e4", "name": "l(r:p1rdm820-p1rlv811)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea28f170-6bf0-47f7-a089-8375dff2ad4a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "052949b1-9e85-4be7-993c-9e97efda3657"}}}], "length": {"value": 0.0433217, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a9571498-62a2-471e-8799-f99e7d47a967", "name": "l(r:p1rdm820-p1rdt455lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53b40b3c-db5a-4fa0-bedb-f293c6eac473"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea28f170-6bf0-47f7-a089-8375dff2ad4a"}}}], "length": {"value": 0.0172275, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "18797b51-4af7-4275-9dee-63bd226546e9", "name": "l(r:p1rdt456lv-p1rlv837)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6abe982-a205-4607-bacf-08e9d7cb6f54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33492e0f-c907-46c6-a529-503480b642bb"}}}], "length": {"value": 0.0139503, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0a607995-b86f-4370-a9b7-e32ca59422de", "name": "l(r:p1rdm822-p1rlv779)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3cae47a-4077-44e6-9761-fc30d85c3442"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fbc761bf-480c-465c-9479-279832c50bc2"}}}], "length": {"value": 0.0269896, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f52fa39d-c9fd-4e85-85bc-c2a8df92edbc", "name": "l(r:p1rdm822-p1rdt456lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6abe982-a205-4607-bacf-08e9d7cb6f54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3cae47a-4077-44e6-9761-fc30d85c3442"}}}], "length": {"value": 0.0541811, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "656582d9-cadf-4851-9af9-1fedf3643435", "name": "l(r:p1rdm823-p1rlv831)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84ca6719-0bbc-440a-b0eb-23b8f32dcf47"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4b6c4e-78d0-4c8e-907c-619f1e43c149"}}}], "length": {"value": 0.0211142, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c7c588e1-b801-4e20-968d-74dbf8bb0382", "name": "l(r:p1rdm823-p1rdt456lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6abe982-a205-4607-bacf-08e9d7cb6f54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84ca6719-0bbc-440a-b0eb-23b8f32dcf47"}}}], "length": {"value": 0.0102805, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "836ed46a-5f6d-4870-8499-1278a9ec7351", "name": "l(r:p1rdt457lv-p1rlv780)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "866745cc-62c9-429f-8389-fcc5a1710f17"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20dcf67f-f04f-498a-830d-557ba7b4d867"}}}], "length": {"value": 0.0223005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8a6c23db-3a7c-425d-b48b-633fdc42fc2c", "name": "l(r:p1rdm826-p1rlv783)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf7e29df-0880-4c8c-aa5c-c43f24dd820e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d1a96d5-f971-4116-9642-769ef5b97e7c"}}}], "length": {"value": 0.0163209, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7ed37ca1-5449-46b0-8458-47d0591766d5", "name": "l(r:p1rdm826-p1rlv795)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf7e29df-0880-4c8c-aa5c-c43f24dd820e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb137176-0642-4d87-ae40-1b7b0e1cb214"}}}], "length": {"value": 0.0159024, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1d6bc55d-4607-481e-9105-0b616cb72843", "name": "l(r:p1rdm827-p1rlv791)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8fafab6a-7d1c-4b87-94b3-5bc4d09ff95d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fe9bb3f-e3c1-4b59-b39f-f62271a55bdd"}}}], "length": {"value": 0.0242315, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5bb2309e-ef7a-4950-be3f-4ea437e50a10", "name": "l(r:p1rdm826-p1rdm827)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf7e29df-0880-4c8c-aa5c-c43f24dd820e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8fafab6a-7d1c-4b87-94b3-5bc4d09ff95d"}}}], "length": {"value": 0.0328507, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "dad113c6-9e9e-4700-9435-c7ff0a205da7", "name": "l(r:p1rdm826-p1rdt457lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "866745cc-62c9-429f-8389-fcc5a1710f17"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf7e29df-0880-4c8c-aa5c-c43f24dd820e"}}}], "length": {"value": 0.0167732, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d1330071-2d41-4078-9307-b70a676ad0f8", "name": "l(r:p1rdm829-p1rlv801)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc2d45e2-caa5-4f7d-976e-ccb045c30559"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ecc45b2-1fbe-4a31-995f-e2f8fffe61a7"}}}], "length": {"value": 0.0173132, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6d008500-ace5-48f8-b33f-b4d50e08262d", "name": "l(r:p1rdm829-p1rlv817)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc2d45e2-caa5-4f7d-976e-ccb045c30559"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11064c6f-3b7a-43b5-96ca-7ef96be3815e"}}}], "length": {"value": 0.0169258, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bbc1606e-a1f3-4038-adcb-7d343a8b0784", "name": "l(r:p1rdm829-p1rdt457lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "866745cc-62c9-429f-8389-fcc5a1710f17"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc2d45e2-caa5-4f7d-976e-ccb045c30559"}}}], "length": {"value": 0.0335366, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9afa8eb4-0776-4773-bde9-230acba79717", "name": "l(r:p1rdm831-p1rlv781)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c668ab72-249e-4463-a3b4-863c7fe826c1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98c5ba15-a339-478a-a79f-9298fab16a54"}}}], "length": {"value": 0.0157907, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ec1f3dfe-9be2-448d-895d-a61b55020888", "name": "l(r:p1rdm831-p1rdt458lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67e071ab-e3dc-4779-9e81-585547cd22ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c668ab72-249e-4463-a3b4-863c7fe826c1"}}}], "length": {"value": 0.0148102, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "737caffb-1251-4b71-ad12-6e6bd5bcc4ab", "name": "l(r:p1rdm832-p1rlv843)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "92f03cbf-2585-4e0e-ab0a-cda0b267b34d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3bc013f-c78d-4a3c-b27f-826c3025de0e"}}}], "length": {"value": 0.0182301, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "be49c7ea-d626-4897-b7c0-0ea973232fd8", "name": "l(r:p1rdm832-p1rdt458lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67e071ab-e3dc-4779-9e81-585547cd22ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "92f03cbf-2585-4e0e-ab0a-cda0b267b34d"}}}], "length": {"value": 0.0184885, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5925af09-96ab-46bf-abc1-3ec6d4d2624c", "name": "l(r:p1rdt459lv-p1rlv782)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9eb57d99-ae80-43da-b0cb-b26bdd583e1a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78a4f54a-017a-41b0-85c8-b3e408c21c08"}}}], "length": {"value": 0.0258607, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8d191be9-fb1c-439a-ac8b-e150326846f5", "name": "l(r:p1rdt460lv-p1rlv784)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028bc055-0ee6-4729-8cd2-15bd7153f975"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2823b5b9-bcc3-4b30-9874-89dc33ec80d2"}}}], "length": {"value": 0.0153083, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "01c60984-030f-4370-8898-c1ca4a48a722", "name": "l(r:p1rdt460lv-p1rlv797)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028bc055-0ee6-4729-8cd2-15bd7153f975"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b1c34f1-2613-46aa-9a9f-686ee518e559"}}}], "length": {"value": 0.0114124, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "983e5468-f132-471e-8de4-a2d98111b7bd", "name": "l(r:p1rdm837-p1rlv806)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "790d0b88-fed2-4c90-bfdf-44d3c31d3d8d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d9f269a-e476-4b82-a258-479d812d008d"}}}], "length": {"value": 0.0126883, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2cfbe94b-e247-4450-bba8-f81b935875b7", "name": "l(r:p1rdm835-p1rlv796)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0e1d710-2ab1-43ca-a7c1-8f05a6c0b753"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59662cef-c126-4188-ad86-844f6cabaf34"}}}], "length": {"value": 0.0156616, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4fe3046b-4238-4a56-b548-8a1681e4538b", "name": "l(r:p1rdm835-p1rdm837)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "790d0b88-fed2-4c90-bfdf-44d3c31d3d8d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0e1d710-2ab1-43ca-a7c1-8f05a6c0b753"}}}], "length": {"value": 0.0179452, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2f533d69-4418-47da-be78-5ac5b4c94399", "name": "l(r:p1rdm837-p1rdt460lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028bc055-0ee6-4729-8cd2-15bd7153f975"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "790d0b88-fed2-4c90-bfdf-44d3c31d3d8d"}}}], "length": {"value": 0.0703462, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e073f275-9a06-4a39-b591-4624acf201a2", "name": "l(r:p1rdm838-p1rlv810)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83fdcccd-6a26-4311-aad3-da67dac5af42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb4a881f-684d-48e4-a6f0-5832f73d140a"}}}], "length": {"value": 0.0133783, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a23cc94c-4329-4e58-908f-3f124f3c4745", "name": "l(r:p1rdm839-p1rlv822)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "344c24ef-9d54-4c1a-9aa4-852a76ddbec7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7ce197c-cee4-40df-b1d7-be13f1be8bb1"}}}], "length": {"value": 0.026775, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9052c72c-1afa-4aae-ab91-a44fd081b6e6", "name": "l(r:p1rdm840-p1rlv839)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0649432-ddb6-4648-8efe-27ee1fd959e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48e97be9-1f80-457f-a56e-79f54458c620"}}}], "length": {"value": 0.0161282, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7b128ad7-4208-4cdc-8fe3-a452dcc56bf8", "name": "l(r:p1rdm839-p1rdm840)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "344c24ef-9d54-4c1a-9aa4-852a76ddbec7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0649432-ddb6-4648-8efe-27ee1fd959e4"}}}], "length": {"value": 0.0193155, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6751f34e-86f1-4742-bcbf-9599466eaa30", "name": "l(r:p1rdm838-p1rdm839)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83fdcccd-6a26-4311-aad3-da67dac5af42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "344c24ef-9d54-4c1a-9aa4-852a76ddbec7"}}}], "length": {"value": 0.0193228, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a3012458-a638-42aa-9386-6e16993d49e7", "name": "l(r:p1rdm838-p1rdt460lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028bc055-0ee6-4729-8cd2-15bd7153f975"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83fdcccd-6a26-4311-aad3-da67dac5af42"}}}], "length": {"value": 0.0193155, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0ea070ec-3b8d-4c37-8cf9-11c6930961e5", "name": "l(r:p1rdm841-p1rlv785)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "505b390e-ffd3-482a-8ae9-b8d6bd8be94f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa98d6c6-7086-4033-a9af-c0a33e802942"}}}], "length": {"value": 0.0383319, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "64541dee-7746-4e3a-93ea-f335ec5f5254", "name": "l(r:p1rdm841-p1rdt461lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd9a4931-435b-4b48-907c-024c0b8a4816"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "505b390e-ffd3-482a-8ae9-b8d6bd8be94f"}}}], "length": {"value": 0.0196806, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3ee4a741-0ae5-41a1-9e6f-04e31c8cbce7", "name": "l(r:p1rdm842-p1rlv793)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "172dd9d0-eab4-4481-9edd-f868e6ed87d9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e8c4bc9-0688-43e6-93a8-9664c9b618b7"}}}], "length": {"value": 0.0393311, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e73d98ae-6229-4f85-99ef-3e20d6469868", "name": "l(r:p1rdm842-p1rdt461lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd9a4931-435b-4b48-907c-024c0b8a4816"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "172dd9d0-eab4-4481-9edd-f868e6ed87d9"}}}], "length": {"value": 0.0393612, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "92814b38-b3fd-497d-bd3d-8166ce56fb13", "name": "l(r:p1rdt462lv-p1rlv790)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d96f458-607c-4820-90b1-6fb2625ace7f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf42fa7f-370e-400e-8f6d-76eb8c70ecb9"}}}], "length": {"value": 0.0135001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c513a390-dacc-41d8-84e2-d8c1c494e6af", "name": "l(r:p1rdm843-p1rlv788)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ac64728-e64c-4241-8a3f-b884f11c6393"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9f470d9-6ead-4413-ad8a-7ccc69ae9237"}}}], "length": {"value": 0.0145732, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "78bb8d17-03cd-4ee9-91a7-b347bd572978", "name": "l(r:p1rdm846-p1rlv864)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2086cded-e13c-4683-824e-9e15f99e12e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e2a8871-7bc4-497f-9954-38db92cb3eba"}}}], "length": {"value": 0.0186895, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "13f88096-53de-4f16-99b0-bb6660af5596", "name": "l(r:p1rdm843-p1rdm846)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ac64728-e64c-4241-8a3f-b884f11c6393"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2086cded-e13c-4683-824e-9e15f99e12e8"}}}], "length": {"value": 0.0176441, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c52a3921-ae5b-4628-bddd-3ff0bd8a700c", "name": "l(r:p1rdm843-p1rdt462lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d96f458-607c-4820-90b1-6fb2625ace7f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ac64728-e64c-4241-8a3f-b884f11c6393"}}}], "length": {"value": 0.0186824, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cc7add68-0788-446c-b784-1994d85a83eb", "name": "l(r:p1rdm845-p1rlv840)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b4620a0-c781-422e-8cc7-3ceed9a0c8dc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "024961c3-25f4-4a15-a52a-7f88dc652766"}}}], "length": {"value": 0.046968, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "65243760-4f2f-4d5d-8d33-e47ffe9a3b4c", "name": "l(r:p1rdm845-p1rlv865)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b4620a0-c781-422e-8cc7-3ceed9a0c8dc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abdfa5db-c398-4638-805d-6d55597e1921"}}}], "length": {"value": 0.0131897, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b331290f-e764-4cff-b625-e8475759c1a7", "name": "l(r:p1rdm845-p1rlv867)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b4620a0-c781-422e-8cc7-3ceed9a0c8dc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a7cca48-fd4b-4630-a479-55f2b6ada03b"}}}], "length": {"value": 0.0296877, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "bc9614b3-e07c-4eab-b885-d06bc6380a70", "name": "l(r:p1rdm845-p1rdt462lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d96f458-607c-4820-90b1-6fb2625ace7f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b4620a0-c781-422e-8cc7-3ceed9a0c8dc"}}}], "length": {"value": 0.0137562, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "25952ee5-154e-4e8f-9fa0-73f87e781bd5", "name": "l(r:p1rdt463lv-p1rlv792)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f660c35e-85f8-4f0e-b03b-806006c76c67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f806232e-0a52-46d5-80f7-7ea3a914137a"}}}], "length": {"value": 0.0161855, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b48f1192-2fba-4630-93a6-3be9d6b52672", "name": "l(r:p1rdm850-p1rlv860)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c397a5a5-21bc-4f4d-9f24-7af1219b70e7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bada1117-5605-4aec-9314-8013ed243e3c"}}}], "length": {"value": 0.0408644, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d33c5ecb-5a3f-4998-a939-ade4ab891a57", "name": "l(r:p1rdm850-p1rdt463lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f660c35e-85f8-4f0e-b03b-806006c76c67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c397a5a5-21bc-4f4d-9f24-7af1219b70e7"}}}], "length": {"value": 0.013479, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2e6bf64f-c3c4-4d85-9090-27d3db1d86e7", "name": "l(r:p1rdt464lv-p1rlv794)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "749e07aa-74ce-40f2-a352-9c55f9914377"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eecc456-41af-4242-ab30-d8ca45d55a2c"}}}], "length": {"value": 0.0144527, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c1905497-9abe-4faa-bd82-2075dd0d3940", "name": "l(r:p1rdm852-p1rlv825)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17b42dae-f856-4945-ba7a-9d3f47e049fe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d209dff6-7a24-41ef-947a-8c6f79c2d65c"}}}], "length": {"value": 0.0239195, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "49992f45-5856-436a-a479-f60b021e18fc", "name": "l(r:p1rdm852-p1rdt464lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "749e07aa-74ce-40f2-a352-9c55f9914377"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17b42dae-f856-4945-ba7a-9d3f47e049fe"}}}], "length": {"value": 0.0188143, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ee5d8865-3fd3-4795-a0b8-dfd4e9a93cac", "name": "l(r:p1rdm853-p1rlv829)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08c93f8a-9600-4ffd-8e18-576d433ce777"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e3a1bd0-69fe-42bb-993d-2094ecc658ce"}}}], "length": {"value": 0.016328, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bccbc133-6fa8-4fa3-a2bc-802cdda86910", "name": "l(r:p1rdm853-p1rdt464lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "749e07aa-74ce-40f2-a352-9c55f9914377"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08c93f8a-9600-4ffd-8e18-576d433ce777"}}}], "length": {"value": 0.0188277, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c3fc0daf-894b-469f-9e4e-90bd63d9f129", "name": "l(r:p1rdm855-p1rlv809)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5ad091a-3b6a-4069-a642-104c28a94dc4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e0f8ee8-795f-4bea-bf7a-e2c477eefb89"}}}], "length": {"value": 0.0141744, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1520e88a-1c47-4c6d-8a0d-2904cb8c3a88", "name": "l(r:p1rdm855-p1rdt465lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "433b0872-49c4-452c-941c-8083a72840ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5ad091a-3b6a-4069-a642-104c28a94dc4"}}}], "length": {"value": 0.0498634, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d406b735-8fac-47c1-b56e-db92b40af1d0", "name": "l(r:p1rdm856-p1rlv862)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eaf112db-b9dc-4d90-b030-3e26188aaf2b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5e2c3a2-32c0-4bb9-9802-265cec784974"}}}], "length": {"value": 0.0132627, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c94f9ba6-f842-44b4-937f-ca55007e9b89", "name": "l(r:p1rdm854-p1rlv798)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb73d9f2-aefb-430c-babd-ac02422eb212"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c30005d7-7e42-4a08-8935-0c7227fba4a6"}}}], "length": {"value": 0.0514932, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "fe2fe4cc-1ca1-49ea-ace0-0dbe19fab608", "name": "l(r:p1rdm854-p1rdm856)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eaf112db-b9dc-4d90-b030-3e26188aaf2b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb73d9f2-aefb-430c-babd-ac02422eb212"}}}], "length": {"value": 0.0253738, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2708a02c-5630-4ed5-bb7d-7e48b577f60a", "name": "l(r:p1rdm856-p1rdt465lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "433b0872-49c4-452c-941c-8083a72840ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eaf112db-b9dc-4d90-b030-3e26188aaf2b"}}}], "length": {"value": 0.0330337, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2d1d33df-5e6c-431b-a65b-5d1417397b37", "name": "l(r:p1rdm857-p1rlv799)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c274aa99-a566-4915-83af-7115bec586b1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f706d9d-0cb1-453b-9ca5-377f7d766099"}}}], "length": {"value": 0.022264, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "10265fad-8f7c-43c0-865e-ed7430319af3", "name": "l(r:p1rdm857-p1rdt466lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f422478c-0d77-48c8-87fb-e883d945f8a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c274aa99-a566-4915-83af-7115bec586b1"}}}], "length": {"value": 0.0280491, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "bc234c0a-aedd-48db-91de-21fa0c5454f3", "name": "l(r:p1rdm858-p1rlv815)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "caa7d639-522c-4fd6-8b74-73a337bd67d2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a134556-828b-4e0c-8773-2f207802e33a"}}}], "length": {"value": 0.011569, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9545bc08-0145-463c-b762-538f3e078558", "name": "l(r:p1rdm858-p1rdt466lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f422478c-0d77-48c8-87fb-e883d945f8a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "caa7d639-522c-4fd6-8b74-73a337bd67d2"}}}], "length": {"value": 0.0785759, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9953a9df-5156-41c7-bec3-13c3ee28db49", "name": "l(r:p1rdt467lv-p1rlv802)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23ed76af-dcb2-4333-ae4c-d7439a37cf87"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2436086-d5c4-4b70-a402-e7d1b6f5b77e"}}}], "length": {"value": 0.023669900000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2548bca4-fda9-4a73-910a-19b98378697f", "name": "l(r:p1rdm861-p1rlv823)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a4bf0e0-92f0-4cd9-afc5-65d9ed242271"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81802469-7320-47e9-b826-fbb33bd371ab"}}}], "length": {"value": 0.0345947, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8f4cba40-f07f-44e4-bac9-1440e21e8bee", "name": "l(r:p1rdm860-p1rlv803)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bfca289-c04c-45d9-8104-40089fc1737e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "018c978c-5673-4090-9792-b75ee161f6d2"}}}], "length": {"value": 0.0184835, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6bde25a7-76c5-4800-9e4b-43f9aeacabc8", "name": "l(r:p1rdm860-p1rdm861)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a4bf0e0-92f0-4cd9-afc5-65d9ed242271"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bfca289-c04c-45d9-8104-40089fc1737e"}}}], "length": {"value": 0.0148709, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fa82ac3a-35f9-4698-aead-a39ffd2d44cf", "name": "l(r:p1rdm861-p1rdt468lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b368fb8f-7f4d-4558-b6b2-2e1db4087727"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a4bf0e0-92f0-4cd9-afc5-65d9ed242271"}}}], "length": {"value": 0.014361200000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "835c6b61-9f3f-4249-9990-71565e51e175", "name": "l(r:p1rdm862-p1rlv833)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1daf402d-faec-4230-b4ab-1efa6283ac0f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eb57fc4-636d-4923-9f4a-d308b062599f"}}}], "length": {"value": 0.019033400000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1b317b7f-25ad-49f7-aeea-76bf76f69a9a", "name": "l(r:p1rdm862-p1rdt468lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b368fb8f-7f4d-4558-b6b2-2e1db4087727"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1daf402d-faec-4230-b4ab-1efa6283ac0f"}}}], "length": {"value": 0.0659529, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "40e9f9b9-d755-457c-ae45-10112f652013", "name": "l(r:p1rdt469lv-p1rlv805)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d12ab15f-746d-462b-b395-e2b330ba1226"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0475b34e-14ab-48e4-9df7-7444de1cde7d"}}}], "length": {"value": 0.0142913, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7eb1f89d-2f21-4647-98bc-44051405b731", "name": "l(r:p1rdt470lv-p1rlv858)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15ab2647-a801-4cb5-a1f7-528118ff5dea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab33ce2f-3131-4cfb-8df2-329fb4aa76b7"}}}], "length": {"value": 0.0299737, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8ee7e39b-981a-4a50-a8aa-4beac6fb4788", "name": "l(r:p1rdm864-p1rlv807)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d861761c-3fe7-437d-917d-8beb24318a42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa259be8-8a61-461a-9e58-d4aaf1ce82db"}}}], "length": {"value": 0.0310907, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "bcb37d15-54f7-4625-abab-989665dada61", "name": "l(r:p1rdm864-p1rdt470lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15ab2647-a801-4cb5-a1f7-528118ff5dea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d861761c-3fe7-437d-917d-8beb24318a42"}}}], "length": {"value": 0.0179311, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5baa0f0e-f822-49b5-9ad4-b3251d29ee4a", "name": "l(r:p1rdt471lv-p1rlv826)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40d98c0b-4c66-4581-9553-f5f57c4b27b9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06746d4d-3db8-45b1-888e-d3d9e405ccaf"}}}], "length": {"value": 0.0163584, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fdac3d14-fa24-42f8-9bae-84816b5ad58b", "name": "l(r:p1rdm866-p1rlv808)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "467753c6-5c1f-4a9d-8a7d-21419b25565f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dcb86a4-e6d7-48b4-b5c2-904635de271b"}}}], "length": {"value": 0.0174196, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0e801fac-7a5f-4816-949a-70e0e49ec4fc", "name": "l(r:p1rdm866-p1rdt471lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40d98c0b-4c66-4581-9553-f5f57c4b27b9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "467753c6-5c1f-4a9d-8a7d-21419b25565f"}}}], "length": {"value": 0.0199112, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "050d509c-ca7e-4b08-84a4-bc625adcd272", "name": "l(r:p1rdt472lv-p1rlv866)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f026a1d3-23b0-4454-a09b-e1c08cc06392"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b4834dc-6bdf-4102-bc13-589392b2e75a"}}}], "length": {"value": 0.0127516, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ed35c9fb-26b6-408a-a136-c0d4237551af", "name": "l(r:p1rdm868-p1rlv812)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0ca3ea5-ad01-4e52-883a-c07805f613dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26fea867-af5f-4213-b9c3-487975d1285e"}}}], "length": {"value": 0.00862481, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "54aae335-7d0d-4c7e-af07-9024a6d3f6cd", "name": "l(r:p1rdm868-p1rdt472lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f026a1d3-23b0-4454-a09b-e1c08cc06392"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0ca3ea5-ad01-4e52-883a-c07805f613dd"}}}], "length": {"value": 0.0108197, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1a29acaa-ce20-4436-aec1-4fbd44cde777", "name": "l(r:p1rdm870-p1rlv813)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aa0c31f-baa3-4db8-87d9-0a4ab9a83a8a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10d44b60-55c0-4d78-abbb-52c8cd67134b"}}}], "length": {"value": 0.0316898, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e094be1d-90f2-49a3-a4e2-2154277e7184", "name": "l(r:p1rdm870-p1rdt473lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f435ec5-8c03-45ba-925b-83bad9501047"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aa0c31f-baa3-4db8-87d9-0a4ab9a83a8a"}}}], "length": {"value": 0.0167209, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c55075c5-7299-40ca-aa59-5710f1dc5ae2", "name": "l(r:p1rdm871-p1rlv818)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67c560cc-d815-41d4-8087-b66beaacb404"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd8c54fd-14d4-46fa-8bef-59c1097d5026"}}}], "length": {"value": 0.0247114, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a4a2af30-2b5e-4c51-8842-5f18a7462994", "name": "l(r:p1rdm871-p1rdt473lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f435ec5-8c03-45ba-925b-83bad9501047"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67c560cc-d815-41d4-8087-b66beaacb404"}}}], "length": {"value": 0.016721, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "33025ab1-b5f9-4e7b-8bc9-e05b23ba208d", "name": "l(r:p1rdt474lv-p1rlv814)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "839858f4-3b18-40c3-86f3-e27225e6aba4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b8065f3-8286-4f99-aa56-b9b631a2f838"}}}], "length": {"value": 0.012214300000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4661a900-6153-47f8-ac49-284e1c025724", "name": "l(r:p1rdt474lv-p1rlv827)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "839858f4-3b18-40c3-86f3-e27225e6aba4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c89db91-40fe-4de6-973e-5d8c23e35080"}}}], "length": {"value": 0.0251297, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "97a99a43-b4cf-4a53-8be1-b6f8c9c9d923", "name": "l(r:p1rdm874-p1rlv816)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ec705b7-fdaa-4eca-96eb-5dabb8256c78"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d6de7c2-fd2c-4071-8e90-1513f521cf87"}}}], "length": {"value": 0.00993642, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5d33e469-fbbc-4dbe-8cc0-037dc6f1521d", "name": "l(r:p1rdm874-p1rdt475lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1be3e20a-3890-4e9c-b568-ca99421e751c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ec705b7-fdaa-4eca-96eb-5dabb8256c78"}}}], "length": {"value": 0.0196806, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3e499df6-5b54-4188-87f6-b114b7ddc9d2", "name": "l(r:p1rdm875-p1rlv834)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c17541ac-d30f-4f0a-9660-f9b9f7012b3a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d437c83c-cbd1-41bf-b455-21123e82d59f"}}}], "length": {"value": 0.0324009, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e4649022-4878-4685-9bfd-6c03c7634b0d", "name": "l(r:p1rdm875-p1rdt475lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1be3e20a-3890-4e9c-b568-ca99421e751c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c17541ac-d30f-4f0a-9660-f9b9f7012b3a"}}}], "length": {"value": 0.0393612, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "aea17153-d289-4fb6-bf02-3c99f43ad7b3", "name": "l(r:p1rdt476lv-p1rlv836)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ffde8c6-9dba-4f13-bda5-a0edf17c736d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12556ab7-c50a-4624-9d84-b85585822245"}}}], "length": {"value": 0.0139229, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d23cc706-758d-4c5f-bfe0-c5d897e7a67d", "name": "l(r:p1rdm878-p1rlv842)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f83e2ade-1911-4124-9fbe-6f482d68eba9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8f304a4-6e39-4288-9b9b-e41bb37c6019"}}}], "length": {"value": 0.015212700000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "34d2a6b1-8462-4bde-bf65-082e9aa25dd8", "name": "l(r:p1rdm878-p1rdt476lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ffde8c6-9dba-4f13-bda5-a0edf17c736d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f83e2ade-1911-4124-9fbe-6f482d68eba9"}}}], "length": {"value": 0.0183516, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1906dc6c-7625-4d68-9c53-d3ec88d367b4", "name": "l(r:p1rdm879-p1rlv868)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "260b560c-e6d6-4069-b67f-067c468a7768"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "009758e3-b4ae-427a-9c30-f2a8bb2953d1"}}}], "length": {"value": 0.0303242, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4573dcbc-735f-4cc2-bedf-3e3bf2bb2e6d", "name": "l(r:p1rdm876-p1rlv820)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5331a4f-ab91-4fea-a301-11b7afb6c8ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41e1e576-4cc9-4fea-9d87-d436f000a675"}}}], "length": {"value": 0.0226825, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "dad50477-3454-429d-889f-7802e2fe03db", "name": "l(r:p1rdm876-p1rdm879)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "260b560c-e6d6-4069-b67f-067c468a7768"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5331a4f-ab91-4fea-a301-11b7afb6c8ca"}}}], "length": {"value": 0.018351400000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2b2c06e9-faf7-4a27-b89e-2fd4aff2d4f9", "name": "l(r:p1rdm879-p1rdt476lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ffde8c6-9dba-4f13-bda5-a0edf17c736d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "260b560c-e6d6-4069-b67f-067c468a7768"}}}], "length": {"value": 0.018351400000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f1cee872-ffd6-4181-91ca-28bc5644d2e5", "name": "l(r:p1rdt477lv-p1rlv821)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7c94703b-303a-4713-95c0-b2933fe0e70b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5578d8b4-7c1e-444f-8d27-8c9bf733f420"}}}], "length": {"value": 0.012208200000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "dae4ec0f-7656-4005-b37e-4f869ca62aaa", "name": "l(r:p1rdt477lv-p1rlv828)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7c94703b-303a-4713-95c0-b2933fe0e70b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08c3f5ef-c2d5-4ce2-8fc7-b665d8cbbab6"}}}], "length": {"value": 0.0188029, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e31a013a-6276-486a-95ad-8156f93c04e3", "name": "l(r:p1rdt478lv-p1rlv824)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c93c776d-68b8-4e4e-8e5e-d5e34003473c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20ce76b6-9305-4525-b77e-b7300edc2c81"}}}], "length": {"value": 0.0283636, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "66a1a477-9441-4daa-8e19-9ae195db32ba", "name": "l(r:p1rdt479lv-p1rlv832)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8037b713-d948-43c9-8370-fb8fcf6dec15"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10373c0d-6a3c-4160-a174-22de447d4c38"}}}], "length": {"value": 0.012648, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1bba640c-d184-4cd8-8d9f-8d718e5d85d0", "name": "l(r:p1rdt480lv-p1rlv835)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "423402f9-4160-481b-9951-a955f8314075"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bc35476-5839-4095-bea5-36e32450b890"}}}], "length": {"value": 0.0370417, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "12477693-3b27-4bb8-9818-8febe1402966", "name": "l(r:p1rdt481lv-p1rlv841)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1761b021-00e0-4880-9f05-62cf67aef0e6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eb6c1b4-f09a-44a5-a13f-64051183736d"}}}], "length": {"value": 0.0229879, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4b8f9b84-3375-44e3-996f-8f2b9b7fc95b", "name": "l(r:p1rdt482lv-p1rlv844)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c445ea76-5167-4d55-b0c5-cc53dadc5b5e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26294827-db76-40b6-b652-1e41efdf15dc"}}}], "length": {"value": 0.0225992, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a38cf1c8-e554-4ff7-9189-f9f0861fb6f3", "name": "l(r:p1rdm887-p1rlv846)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3929a951-8b8b-42e9-a839-40c29e680108"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "145d3757-ca09-45ca-9199-465b6b43fbb7"}}}], "length": {"value": 0.025727, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "72d6b0dd-0037-4a7f-b678-dd0aa4abb16a", "name": "l(r:p1rdm887-p1rdt482lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c445ea76-5167-4d55-b0c5-cc53dadc5b5e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3929a951-8b8b-42e9-a839-40c29e680108"}}}], "length": {"value": 0.0374944, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b6f8b4d2-1bc0-4679-9713-9bcd313232ad", "name": "l(r:p1rdm888-p1rlv848)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0318cdac-5c7b-4711-a0d7-9c7e104c8281"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e484d77-29ac-4903-afa3-f677283db883"}}}], "length": {"value": 0.0169569, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "50bbf606-cb43-4516-91a8-dadf8c13416a", "name": "l(r:p1rdm888-p1rdt482lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c445ea76-5167-4d55-b0c5-cc53dadc5b5e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0318cdac-5c7b-4711-a0d7-9c7e104c8281"}}}], "length": {"value": 0.0374944, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "de9da477-e2e9-4af6-be08-69a14dcb5a12", "name": "l(r:p1rdt483lv-p1rlv845)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "475b6a50-9814-4016-bb88-be5b1b2ac31d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b053d449-b15b-4292-9a73-9b7d104a8e38"}}}], "length": {"value": 0.016859600000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6e28be69-05a4-42ac-ad11-d34b22f52d5d", "name": "l(r:p1rdt483lv-p1rlv851)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "475b6a50-9814-4016-bb88-be5b1b2ac31d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48b5535c-f00d-4b48-a23a-87f3f212302f"}}}], "length": {"value": 0.0190238, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bd6f5a20-0cfc-458e-83ac-da3256bcb423", "name": "l(r:p1rdt483lv-p1rlv859)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "475b6a50-9814-4016-bb88-be5b1b2ac31d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ea0f4f5-2024-45a8-9f8f-f5963e7d2727"}}}], "length": {"value": 0.0273815, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "16ca1d8c-f178-4b98-9b82-1048582e46dc", "name": "l(r:p1rdm892-p1rlv855)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "18ea7daf-9665-4d68-b255-12d41bdb2396"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10611e08-75e2-4422-ac0f-cfb98c7eae4b"}}}], "length": {"value": 0.0184228, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8982efe3-fe34-4f46-8ba6-0da7942cd0e9", "name": "l(r:p1rdm890-p1rlv849)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0398ef91-eeb8-4d34-b05e-e88adabdd487"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a95877ca-8600-4e95-82ac-c51cb82acf16"}}}], "length": {"value": 0.0307799, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "336123d1-06d4-42bc-91ca-b2faf7f420c1", "name": "l(r:p1rdm890-p1rdm892)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "18ea7daf-9665-4d68-b255-12d41bdb2396"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0398ef91-eeb8-4d34-b05e-e88adabdd487"}}}], "length": {"value": 0.0712019, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e18fc9dc-b6c4-48fb-a18a-e11d951be718", "name": "l(r:p1rdm892-p1rdt483lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "475b6a50-9814-4016-bb88-be5b1b2ac31d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "18ea7daf-9665-4d68-b255-12d41bdb2396"}}}], "length": {"value": 0.016043, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0fe81417-b25b-4f18-8740-612e6afbda1c", "name": "l(r:p1rdt484lv-p1rlv847)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f396745a-5edb-4ab8-8bc7-2b181719cbf4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "283142ff-4884-4adc-9d4c-f8615505415a"}}}], "length": {"value": 0.0214364, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cd25035f-8cc9-4351-99d1-da90e1465103", "name": "l(r:p1rdm895-p1rlv856)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e96e4c25-4664-45ae-b77c-9e0047f65c8b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25f84b28-695b-4d32-b96c-914226444b9f"}}}], "length": {"value": 0.0167306, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e2643c5e-63e6-45b4-9a5c-87df5a4bba08", "name": "l(r:p1rdm895-p1rdt484lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f396745a-5edb-4ab8-8bc7-2b181719cbf4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e96e4c25-4664-45ae-b77c-9e0047f65c8b"}}}], "length": {"value": 0.0181803, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e4e3f62f-6a52-4772-8105-017c43ea8625", "name": "l(r:p1rdm896-p1rlv850)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60637f4b-8538-4b21-988c-1b13adecc647"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d49057-9c70-4489-95bb-36b5b574e13d"}}}], "length": {"value": 0.0266685, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c65cddfc-7654-418e-bc98-41fa27f8c007", "name": "l(r:p1rdm896-p1rdt485lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da38ec0a-f37d-4a5c-8da0-93410a8fb475"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60637f4b-8538-4b21-988c-1b13adecc647"}}}], "length": {"value": 0.016779100000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d1a11481-6f65-4363-9e68-bb0fda7a5dc9", "name": "l(r:p1rdm897-p1rlv853)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3464daa0-06b2-4d5d-9901-bb34050fe619"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "365eff25-8ccb-448b-894f-ad662fe6d684"}}}], "length": {"value": 0.0210885, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a013e7d5-c8e8-4c90-8afd-836bd7c9313b", "name": "l(r:p1rdm897-p1rdt485lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da38ec0a-f37d-4a5c-8da0-93410a8fb475"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3464daa0-06b2-4d5d-9901-bb34050fe619"}}}], "length": {"value": 0.014660500000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1fd6bbe3-8659-48dd-aa1f-9e5788d134f1", "name": "l(r:p1rdm898-p1rlv852)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d9b6dee-73e1-43ab-ac9b-7d20fb77b6df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32142941-c546-4356-ba80-123b9128b5de"}}}], "length": {"value": 0.0198361, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c93ddd5b-ec87-4033-ba5f-d8293329e37f", "name": "l(r:p1rdm898-p1rdt486lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5401d366-a5a2-4753-82b7-ce4fa08a1227"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d9b6dee-73e1-43ab-ac9b-7d20fb77b6df"}}}], "length": {"value": 0.03692270000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0dc1cf49-c5f7-475d-958e-e7dfd2b9e65e", "name": "l(r:p1rdm899-p1rlv857)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e5e11ab-e042-4038-85c4-162521871722"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a28cc17a-125d-4b7b-a697-230e3f8853b5"}}}], "length": {"value": 0.0237034, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "00e35878-599e-4958-ab4e-26fccef53f5a", "name": "l(r:p1rdm899-p1rdt486lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5401d366-a5a2-4753-82b7-ce4fa08a1227"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e5e11ab-e042-4038-85c4-162521871722"}}}], "length": {"value": 0.0374944, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b544e958-00d0-45f4-9f80-ee015a8495ec", "name": "l(r:p1rdt487lv-p1rlv854)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47fbd02f-6c12-4bd6-9d6d-2e0cddbfcd88"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2461b6f0-9a40-4b6f-9669-be479da039f3"}}}], "length": {"value": 0.0160302, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7413aa3e-5264-431e-b1ee-96bcb81dc33c", "name": "l(r:p1rdt488lv-p1rlv863)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e517b810-e6b9-4c89-b47d-1921fcf88edc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09a7be46-a1bf-459d-836b-beb64324809b"}}}], "length": {"value": 0.022533, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ac6a59e2-26a8-4380-a237-b8c62ae89797", "name": "l(r:p1rdm901-p1rlv861)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d7f4223-382b-4b9a-9157-baede39de271"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a07d30f-6909-4d74-be8a-1ff8343b4419"}}}], "length": {"value": 0.0239784, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f1b8fe58-3e64-4bad-a83d-6dfa926eb48b", "name": "l(r:p1rdm901-p1rdt488lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e517b810-e6b9-4c89-b47d-1921fcf88edc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d7f4223-382b-4b9a-9157-baede39de271"}}}], "length": {"value": 0.0134887, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b57aaa4c-0468-4c5f-97d9-03a76be33d9d", "name": "l(r:p1rdt489lv-p1rlv869)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25637062-8ca3-4694-a27b-7be93e89fe1f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fb4003d-498a-494d-89ca-f222d921f63a"}}}], "length": {"value": 0.0208895, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "10466c86-9f76-45e1-94a1-237649c34b3b", "name": "l(r:p1rdm7860-p1rlv7783)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "601a7504-69fc-4c21-a1d8-1a59751d439c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd7a84bb-8aa4-4668-9791-a363741823e9"}}}], "length": {"value": 0.0587046, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b9060d54-e5ed-415c-9385-ff4782908000", "name": "l(r:p1rdm7860-p1rdt3776lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ae14df0-ab3b-47ba-9f83-c09f03999c76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "601a7504-69fc-4c21-a1d8-1a59751d439c"}}}], "length": {"value": 0.0312996, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "fe5691e5-0fea-4743-911a-02ac9e6cc1a0", "name": "l(r:p1rdm7861-p1rlv7784)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "391504f7-3b2f-47f0-aadd-47de5c89b16b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24e665a0-3ba6-46a7-bc02-327b6f77c409"}}}], "length": {"value": 0.0188851, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "60a19095-6b29-4d9b-89a0-147f382ffe6f", "name": "l(r:p1rdm7861-p1rdt3776lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ae14df0-ab3b-47ba-9f83-c09f03999c76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "391504f7-3b2f-47f0-aadd-47de5c89b16b"}}}], "length": {"value": 0.016714700000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b3634258-f4ed-44fb-98e6-aab051e298ed", "name": "l(r:p1rdt3777lv-p1rlv7786)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4662f3f5-e75b-4b75-a6d6-7ada745d5cca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af62e3c-9357-4505-a2f6-3b4252dab81b"}}}], "length": {"value": 0.0847582, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2ded4c2a-d082-4ebc-b7cf-7173851ecbf9", "name": "l(r:p1rdm7862-p1rlv7785)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90158ee6-01aa-48ce-867f-8e459e7a5e09"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1571d1a3-a151-4972-8cb1-aeb36b660abc"}}}], "length": {"value": 0.0135756, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cb94f9fd-5645-4d22-80c7-8bbcc0dd1f34", "name": "l(r:p1rdm7862-p1rdt3777lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4662f3f5-e75b-4b75-a6d6-7ada745d5cca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90158ee6-01aa-48ce-867f-8e459e7a5e09"}}}], "length": {"value": 0.0255604, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "17a69667-cf10-4bca-be13-6a7e0e89b592", "name": "l(r:p1rdt5098lv-p1rlv10453)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e734d7a2-9161-41c0-ba78-9f9f87120acd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09926231-b077-4aa6-afd8-acf89744865a"}}}], "length": {"value": 0.011414400000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "37668bd4-db9e-4657-a30f-6537455366f8", "name": "l(r:p1rdt5098lv-p1rlv10468)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e734d7a2-9161-41c0-ba78-9f9f87120acd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a639e8d-ac8c-46e8-a4b5-6c551612b209"}}}], "length": {"value": 0.010426000000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6f4de8f6-9f4d-4326-879d-2b1d1bd70a9b", "name": "l(r:p1rdt5098lv-p1rlv10482)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e734d7a2-9161-41c0-ba78-9f9f87120acd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d40fc87f-1b73-4ed4-a397-dbc94312dcad"}}}], "length": {"value": 0.0457378, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "eb768007-e1fd-4128-843e-a920a8d99c4a", "name": "l(r:p1rdt5098lv-p1rlv10517)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e734d7a2-9161-41c0-ba78-9f9f87120acd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "efd01236-6ba3-424e-829b-3f3950ce6265"}}}], "length": {"value": 0.0527233, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "81dde824-4245-4f8c-a4cf-9db89dc3aeb4", "name": "l(r:p1rdt5548lv-p1rlv11503)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91754be7-2a91-4a0e-9856-43d08ecc7c70"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "773a6b9e-d708-4f7c-a901-9406bcc3dcde"}}}], "length": {"value": 0.0787524, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "e169b7fb-6b4d-42f9-8e7c-3647a7d1c8a2", "name": "l(r:p1rdt5548lv-p1rlv19645)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91754be7-2a91-4a0e-9856-43d08ecc7c70"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7efbb32-55d4-409b-a37f-bf01d0620d40"}}}], "length": {"value": 0.0664224, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "4eeb407c-9ccf-4bbd-b2fb-d4024fbdc2db", "name": "l(r:p1rdm11706-p1rlv19640)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4c77c78-e261-4d17-93ff-caad4d86246b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e90f763-682e-4771-976c-9cd736b72133"}}}], "length": {"value": 0.0418249, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "a13c699c-045f-49d2-b42c-2cdbede20fb5", "name": "l(r:p1rdm11706-p1rdt5548lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91754be7-2a91-4a0e-9856-43d08ecc7c70"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4c77c78-e261-4d17-93ff-caad4d86246b"}}}], "length": {"value": 0.00976661, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "cc6ab775-6ec1-4a88-8795-fda42a10631d", "name": "l(r:p1rdm11719-p1rlv11513)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15ae4af0-db43-4f1b-bd8c-c6be31d034aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84b9d44e-2c8d-4cee-a9d2-327a41ab8dad"}}}], "length": {"value": 0.0190194, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "7790dc5f-cdac-4888-aef5-99f91b95d8f0", "name": "l(r:p1rdm11719-p1rdt5557lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05b867e6-2f18-49e7-9869-55bd5048c201"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15ae4af0-db43-4f1b-bd8c-c6be31d034aa"}}}], "length": {"value": 0.0164873, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "ebcc125c-7f65-4704-b548-f54176c23576", "name": "l(r:p1rdm11720-p1rlv19574)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "effa94d0-34ae-4cbe-b8da-fd1693d47b3a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf457d88-958c-446a-9584-73be8c609bbe"}}}], "length": {"value": 0.0842106, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "d84a4af5-3ffc-4402-94bf-55e2b8fce113", "name": "l(r:p1rdm11720-p1rdt5557lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05b867e6-2f18-49e7-9869-55bd5048c201"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "effa94d0-34ae-4cbe-b8da-fd1693d47b3a"}}}], "length": {"value": 0.0174341, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "9f3e9279-5951-47ea-9614-bfdb64faa25b", "name": "l(r:p1rdt5560lv-p1rlv11516)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5838960-8556-4e4a-95e9-8ba9ffc85141"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86d82a1e-1596-4fb3-9f3d-44c9553396d2"}}}], "length": {"value": 0.034696700000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a10879ee-8cd7-4421-8ad1-8ec8d159db76", "name": "l(r:p1rdt5561lv-p1rlv11517)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "133a0221-0cd5-46d2-af84-e80e7951c96d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "179d1d84-0dfe-4920-a039-009f33bc1d8d"}}}], "length": {"value": 0.0852615, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "3c9c08f9-58e9-4367-aee8-72788caa6a7c"}}}}, {"uuid": "85c749d5-75af-4616-a6ac-4d19148a2db2", "name": "l(r:p1rdt5564lv-p1rlv11521)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8deb73b9-51fc-447d-9da7-14a6dccff646"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8f0f8a2-f528-45bd-8fbd-22f6699fe7e0"}}}], "length": {"value": 0.0157073, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cea46a51-3c46-4491-91ff-28ee6a01fae5", "name": "l(r:p1rdt5566lv-p1rlv11523)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95a5450a-6630-41b8-863f-0c1f3fcfa7ab"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69eba934-3f80-4abc-b5e8-9cdc79aa05a3"}}}], "length": {"value": 0.0858684, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "86229bfc-1da4-4a19-9237-57b2905f74e0", "name": "l(r:p1rdt5568lv-p1rlv11526)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "613d178b-a566-408d-bad0-e4a170eea971"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b97ebb0-09a4-4c42-a10e-e3aff344aa44"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "945a8612-0351-49e2-9f34-8f08e68f05d1", "name": "l(r:p1rdm11742-p1rlv11533)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0460a67f-dcc1-4829-99f8-7a0b6a8cedbc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21b18539-fba6-4b52-b8bf-38c2a6c4abfb"}}}], "length": {"value": 0.05768530000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "93ae1764-d66b-4a19-906e-591b3a1e591f", "name": "l(r:p1rdm11742-p1rlv19643)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0460a67f-dcc1-4829-99f8-7a0b6a8cedbc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f0e181a-fa89-4c5d-a1cb-6080f91331da"}}}], "length": {"value": 0.0190181, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "3dbe6d40-2137-4381-80f7-1f5a50ac28df", "name": "l(r:p1rdm11742-p1rdt5574lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "248e065d-80ed-4926-9625-295c83da6b61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0460a67f-dcc1-4829-99f8-7a0b6a8cedbc"}}}], "length": {"value": 0.00976661, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "793d8149-e4ef-4652-883e-e9f4c27a7e76", "name": "l(r:p1rdm11743-p1rlv19610)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6554d73d-5cf7-4531-a524-78e70b36fd8d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "813f887e-6807-4ffc-90bf-bd30cde9a9df"}}}], "length": {"value": 0.0248503, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "5cc69a86-7b23-4389-bb35-5abe701b58fd", "name": "l(r:p1rdm11743-p1rdt5574lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "248e065d-80ed-4926-9625-295c83da6b61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6554d73d-5cf7-4531-a524-78e70b36fd8d"}}}], "length": {"value": 0.00976769, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "a326f1c4-da78-4141-9db0-66d576e8b34a", "name": "l(r:p1rdt5577lv-p1rlv11540)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21ef4ae6-b80e-49f1-8d00-1cb6e27bc8f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1148946c-8c37-4482-afce-5082cd2b7ad4"}}}], "length": {"value": 0.0511394, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "12bccd3a-fe76-4b06-b5e9-4ecf0bc45c74", "name": "l(r:p1rdt5577lv-p1rlv11540)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1148946c-8c37-4482-afce-5082cd2b7ad4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f79b14c8-e77d-49c1-9336-e7407ad4c94d"}}}], "length": {"value": 0.00462191, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f0e70843-a66a-4f1c-9ec8-537f478ceb4c", "name": "l(r:p1rdt5577lv-p1rlv19608)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21ef4ae6-b80e-49f1-8d00-1cb6e27bc8f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "752bcf04-7a44-42b0-9a46-44c243b78eb5"}}}], "length": {"value": 0.0743006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "8827a427-b95c-48ee-bab2-53830e656715", "name": "l(r:p1rdt5577lv-p1rlv19608)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "752bcf04-7a44-42b0-9a46-44c243b78eb5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f917b142-d59f-4a51-8c3b-913feb53411d"}}}], "length": {"value": 0.0771446, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9b7200ad-1df7-439b-b20d-bb9280f9771d", "name": "l(r:p1rdm13355-p1rlv13033)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5559c15-cdac-4a4d-a2a0-b99c9befb310"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1564c5f9-8b80-41b4-af09-2a55dee0718b"}}}], "length": {"value": 0.014252, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e1bf48e6-13e2-4a91-89cf-5d84620d1588", "name": "l(r:p1rdm13355-p1rdt6261lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9859b30-0238-493e-be1a-cb6717413ba9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5559c15-cdac-4a4d-a2a0-b99c9befb310"}}}], "length": {"value": 0.0141814, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "aa2af72e-9572-4467-97d9-6b9af030b224", "name": "l(r:p1rdm13356-p1rlv13036)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba5e6363-0b23-4726-8013-f3d040511005"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23aae8f1-8b9f-4453-9643-b49ffdc80889"}}}], "length": {"value": 0.0296258, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2ca1fa28-2d13-4dfb-b49d-74e91cec5353", "name": "l(r:p1rdm13356-p1rdt6261lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9859b30-0238-493e-be1a-cb6717413ba9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba5e6363-0b23-4726-8013-f3d040511005"}}}], "length": {"value": 0.0175481, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "17ea358b-1515-4a7e-b9cc-da4cd723e829", "name": "l(r:p1rdt6262lv-p1rlv13034)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2172b57-622b-44c1-8388-f1e2b1def312"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3b7bff1-90da-4ee2-8a0f-8e291a7e8ac8"}}}], "length": {"value": 0.012931, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cd2a9d82-271b-4297-97f5-86ec2233a7f8", "name": "l(r:p1rdt6262lv-p1rlv13040)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2172b57-622b-44c1-8388-f1e2b1def312"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6839f65-9d3b-4bd6-89a4-0c8feb33e98a"}}}], "length": {"value": 0.012931, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cbc3d861-03cf-41fd-9899-1877d9629f93", "name": "l(r:p1rdt6263lv-p1rlv13035)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4717b000-fd39-4647-9fbd-5152323dacee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6d309ef-b082-4022-a265-4891cdcd6db9"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "5f45d635-24d4-4b92-b676-91cb371f21c7", "name": "l(r:p1rdt6264lv-p1rlv13037)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e916c16-525d-4092-b627-ad44b4bf4ee8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f5d04aa-74fb-4d1a-ac91-6c01a56a94b5"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "f0aff012-ca25-4a95-afab-ae5b5acd6b86", "name": "l(r:p1rdt6265lv-p1rlv13038)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6bb5544-e583-4ded-9a10-23be70f5598e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a8b4502-31fd-4dce-8717-9860880075b4"}}}], "length": {"value": 0.0390031, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "407a9766-0e87-492a-a15d-f38706b3f5d7", "name": "l(r:p1rdt6265lv-p1rlv13039)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6bb5544-e583-4ded-9a10-23be70f5598e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34d43081-e4a3-4f1b-8b90-5965458452d0"}}}], "length": {"value": 0.0390031, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1ecf47fb-4c9d-4c2f-9b13-48fc566a1ff4", "name": "l(r:p1rdt6266lv-p1rlv13041)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8af5f9d5-965c-4a0c-a811-67d3bed744ee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60144ce1-d4d6-4725-b543-f881894356a5"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "97e95d76-b07f-4991-830b-e51976983721", "name": "l(r:p1rdt6267lv-p1rlv13042)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0ddd898-3193-4bff-80f4-fd4a7eae9aec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "296cd07e-c2e3-4031-abad-9c870a65105d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "3867ca21-d32f-4f5c-940d-37211d717384", "name": "l(r:p1rdt6488lv-p1rlv13513)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1155c2c-544c-45f4-969f-b3ec4f6773bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3243ca2f-a97e-4fbc-981d-85eded2e5e6b"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "d02d53af-3a36-4ac6-9b80-9d033180548f", "name": "l(r:p1rdt6578lv-p1rlv13823)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "555453a3-3fb7-426a-bbd2-9e588d4bd01d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0ca6e47-afec-4d61-885a-e38176b32444"}}}], "length": {"value": 0.047603, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "846f4229-8275-4972-b164-2502491188e2", "name": "l(r:p1rdm14192-p1rlv13789)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2fe65b3-6fcc-4416-bca4-9a0f6551b801"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47a7519a-b550-41e6-99e3-c2115db425fe"}}}], "length": {"value": 0.049152900000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6f4fa352-b028-47aa-9d50-18a0bb0a9afe", "name": "l(r:p1rdm14192-p1rlv13796)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2fe65b3-6fcc-4416-bca4-9a0f6551b801"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94ac9254-cdbf-4864-b22b-bcfb0a827700"}}}], "length": {"value": 0.0270402, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0b124dff-b54f-45fa-a5d5-8c433190d495", "name": "l(r:p1rdm14192-p1rdt6578lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "555453a3-3fb7-426a-bbd2-9e588d4bd01d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2fe65b3-6fcc-4416-bca4-9a0f6551b801"}}}], "length": {"value": 0.014767000000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e71fa7ac-b9d3-4a12-b0d7-044c378b6c67", "name": "l(r:p1rdm14194-p1rlv13814)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e0be7c1-65b8-4de4-89f2-56b6bf1ea321"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028d5ead-7c34-400b-bcc1-c4d706c965d3"}}}], "length": {"value": 0.0199421, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "09b39023-2ff0-4d96-a0ed-ac8b59606a15", "name": "l(r:p1rdm14194-p1rdt6578lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "555453a3-3fb7-426a-bbd2-9e588d4bd01d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e0be7c1-65b8-4de4-89f2-56b6bf1ea321"}}}], "length": {"value": 0.0147579, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "57580946-6dbd-4b0c-98d1-8cad145603ef", "name": "l(r:p1rdt6580lv-p1rlv13791)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5de250a8-ecca-4ab4-9f09-685aaf92d13d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "251f270f-4238-4fe6-8ab3-f884fca7a42d"}}}], "length": {"value": 0.021088, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "aa0e6dd2-2c0f-4177-a823-a0468aa4d055", "name": "l(r:p1rdt6580lv-p1rlv13810)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5de250a8-ecca-4ab4-9f09-685aaf92d13d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab29ca66-d59b-4aa6-b5f6-165add0bc331"}}}], "length": {"value": 0.0102831, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7a87292e-c6a6-4051-9120-26457ad60aa0", "name": "l(r:p1rdt6580lv-p1rlv13815)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5de250a8-ecca-4ab4-9f09-685aaf92d13d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99957459-46a6-4b2b-9813-69b11ca7dad1"}}}], "length": {"value": 0.0257571, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cd0d76c4-750e-4a91-bf36-2fc25a0839cf", "name": "l(r:p1rdt6580lv-p1rlv13819)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5de250a8-ecca-4ab4-9f09-685aaf92d13d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36c12a74-a2ca-439a-a69f-308dd5cb1207"}}}], "length": {"value": 0.0290939, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "506334ac-668e-40db-b38e-3b096457209b", "name": "l(r:p1rdt6584lv-p1rlv13817)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d944119-3782-49dd-8b24-1f68d8ee687c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e96bcc5b-07c5-4289-aec4-0224395c5e8a"}}}], "length": {"value": 0.0927796, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f4e84bae-8f8c-4be0-8536-cd28853d2d45", "name": "l(r:p1rdm14215-p1rlv13801)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "39af24f1-0fa2-465e-a288-2b620d9e9d59"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "accec892-a236-462d-b714-1178393ec992"}}}], "length": {"value": 0.0671973, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0a048391-5c17-4012-930f-0b72f82b3505", "name": "l(r:p1rdm14215-p1rdt6584lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d944119-3782-49dd-8b24-1f68d8ee687c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "39af24f1-0fa2-465e-a288-2b620d9e9d59"}}}], "length": {"value": 0.0384386, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "15c6bf63-883d-4801-a272-90fa9b89b00d", "name": "l(r:p1rdm14218-p1rlv13822)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32db643a-7c82-4816-8629-7935cab09567"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ade9991-a857-4619-8094-c18f824aaeb9"}}}], "length": {"value": 0.06771510000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6f9c9704-6507-461c-8562-66721f90efd2", "name": "l(r:p1rdm14216-p1rlv13807)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e81f150f-30cd-4c9a-b5b7-7a633633702d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c26fba44-3b81-47de-81e6-522f2daf0534"}}}], "length": {"value": 0.0529333, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "87f002f2-9fae-464e-bb80-cb01a6a0b754", "name": "l(r:p1rdm14216-p1rdm14218)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32db643a-7c82-4816-8629-7935cab09567"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e81f150f-30cd-4c9a-b5b7-7a633633702d"}}}], "length": {"value": 0.0151179, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b1fec959-7ba6-4215-b96e-6ba2d1d19620", "name": "l(r:p1rdm14218-p1rdt6584lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d944119-3782-49dd-8b24-1f68d8ee687c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32db643a-7c82-4816-8629-7935cab09567"}}}], "length": {"value": 0.0151258, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7c60e0a9-3fcc-4eba-95b4-8df243a36579", "name": "l(r:p1rdt6587lv-p1rlv13808)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c587698-7940-4edb-9105-f31f1304f7e9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c795ac7-3b49-4158-996d-2fb1f0337847"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "00db7f54-776f-48ee-8e74-66239598eba8", "name": "l(r:p1rdt6588lv-p1rlv13809)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61045f72-ca3d-4e0d-ac3d-db5fbf099b38"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "687996da-ab03-4544-b0d9-b79b8ac88e95"}}}], "length": {"value": 0.0528036, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7dd2b848-aa22-4412-b1d1-8022419948bd", "name": "l(r:p1rdt6590lv-p1rlv13820)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a289017a-8ab9-4412-857a-694b3aa2c63d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a2caa70b-9143-4676-834b-bfc7cb41330c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "cce20032-6f5e-4e62-a614-f8c3e1c1e558", "name": "l(r:p1rdt6591lv-p1rlv13821)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a7c2e99-857f-4119-be4a-daaca586f056"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66e6c732-919a-4851-9f76-5580ea71669d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "e2cf222a-6a6e-4c2b-88b3-ae9dc77d477b", "name": "l(r:p1rdt7286lv-p1rlv15585)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ad975da-cce7-49cb-be78-20c4abf8975e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17bf6d8f-8215-4294-b921-cc3e34476f1e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "0b6321c0-e593-4fd0-83ef-ccdacf1bca96", "name": "l(r:p1rdt7289lv-p1rlv15590)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56d21681-3c57-4575-af17-f2bbf9874a10"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef2a4478-4644-4bd3-9548-ab1d0be338b5"}}}], "length": {"value": 0.0486531, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a57e0543-e448-4364-97ea-0ec58bfe1197", "name": "l(r:p1rdt7289lv-p1rlv15591)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56d21681-3c57-4575-af17-f2bbf9874a10"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c04c9ad1-4277-47de-9cec-9ce86e17b4f1"}}}], "length": {"value": 0.0486531, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f9dc052c-0cf6-496a-bdae-32b7e4c0991c", "name": "l(r:p1rdt7293lv-p1rlv15595)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9b0c16f-f433-4aa1-8d00-dc1573dfb5e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "629e2259-2a59-4b20-b8bf-7b3b2c4a48f9"}}}], "length": {"value": 0.0100375, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b490b873-d978-4e8e-b731-5d1a1177b231", "name": "l(r:p1rdt7293lv-p1rlv15598)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9b0c16f-f433-4aa1-8d00-dc1573dfb5e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "af6b7d1b-896f-44ac-8038-748c74507253"}}}], "length": {"value": 0.0100375, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "aaeb1a63-1faf-4245-8aac-9d7ee893de31", "name": "l(r:p1rdm16003-p1rlv15599)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c1ea087-8a4d-49ca-af35-b86aed849c98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ae1bbf1-459f-4346-b525-393b7d1dc958"}}}], "length": {"value": 0.05559190000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6a2caec6-4161-4515-ba83-a4255da193f2", "name": "l(r:p1rdm16003-p1rdt7294lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67d2b31-f05a-4160-83ae-55154224a9ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c1ea087-8a4d-49ca-af35-b86aed849c98"}}}], "length": {"value": 0.0102952, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fd8a75f0-e4cc-4f0d-9f5a-a88b8512defb", "name": "l(r:p1rdm16004-p1rlv15618)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84040096-aca8-4cee-8539-83ae8f875e98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "200aa7d8-0a43-4086-b0e7-f63cae75671d"}}}], "length": {"value": 0.0495647, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2f1ec0c6-1240-41df-9dbd-567f072a135c", "name": "l(r:p1rdm16004-p1rdt7294lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67d2b31-f05a-4160-83ae-55154224a9ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84040096-aca8-4cee-8539-83ae8f875e98"}}}], "length": {"value": 0.0103008, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "228ab804-b7eb-4baa-8890-32957676b9b3", "name": "l(r:p1rdm16011-p1rlv15604)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "381018f1-11cd-4519-ad24-d3419116ea84"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95b45d46-b7e7-46e2-98d9-5034e2fa0a17"}}}], "length": {"value": 0.0544244, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8c2aa039-c379-41ae-a2bc-c5676e9b8d5c", "name": "l(r:p1rdm16011-p1rdt7299lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4cee417a-3410-4907-8621-f0d3fcbc047c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "381018f1-11cd-4519-ad24-d3419116ea84"}}}], "length": {"value": 0.011971, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e8772813-cf45-4c0c-bfb1-0fa439dccaa4", "name": "l(r:p1rdm16012-p1rlv15616)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60d0a9cf-54f3-4049-9957-29839b7beb08"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43ed408e-35e2-4bca-9060-a0c211aea1e7"}}}], "length": {"value": 0.05365020000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e0c373ed-e460-4f34-a8d1-eb847e2f7d41", "name": "l(r:p1rdm16012-p1rdt7299lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4cee417a-3410-4907-8621-f0d3fcbc047c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60d0a9cf-54f3-4049-9957-29839b7beb08"}}}], "length": {"value": 0.011961, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7fc7557d-3188-421b-9deb-23156c311c75", "name": "l(r:p1rdt7300lv-p1rlv15605)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "135a6a49-6562-4c6e-a41f-f5f78c0ac3e6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcbee2ff-bf73-4834-bc3c-46fa0cfcad7c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "fb196b4b-b9e0-4682-9687-fc7b48814c94", "name": "l(r:p1rdt7303lv-p1rlv15608)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7cbc8145-b198-46f1-a3fd-55a05637e618"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13d6bce6-9066-43a1-b2b6-00a2a4398958"}}}], "length": {"value": 0.09331, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e5a601cd-32a4-4b1b-9279-6c052d0a0c67", "name": "l(r:p1rdt7308lv-p1rlv15619)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5094655-6494-44a9-b0ff-c5b418dcc11e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905a4857-5d3d-4e51-9ab0-70d634170f92"}}}], "length": {"value": 0.0449182, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "69eca3e0-a956-498c-b4de-f0459f13be05", "name": "l(r:p1rdt7308lv-p1rlv15641)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5094655-6494-44a9-b0ff-c5b418dcc11e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4363602a-eb9c-41b8-8130-7bb839f4eb5a"}}}], "length": {"value": 0.0129519, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8b756ba9-f09a-4289-8963-ac6c4c3bb912", "name": "l(r:p1rdm16029-p1rlv15623)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2fba947f-089b-47f3-8720-e8f3e35c097c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13f790a1-18c0-498f-8525-fbaf0350947b"}}}], "length": {"value": 0.0220545, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "88313a2a-a20c-49c2-b01d-be23bb684a18", "name": "l(r:p1rdm16029-p1rdt7308lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5094655-6494-44a9-b0ff-c5b418dcc11e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2fba947f-089b-47f3-8720-e8f3e35c097c"}}}], "length": {"value": 0.0183549, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "878d6ef7-4b7f-4b3d-9231-3c35685646c9", "name": "l(r:p1rdm16030-p1rlv15625)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "154999cc-f6d5-458a-8504-e4692344d372"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb08eda2-b277-4bfd-9ea0-9c36765400bd"}}}], "length": {"value": 0.011861000000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "af04168d-2e01-467c-a933-57eb91eefb0e", "name": "l(r:p1rdm16030-p1rdt7308lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5094655-6494-44a9-b0ff-c5b418dcc11e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "154999cc-f6d5-458a-8504-e4692344d372"}}}], "length": {"value": 0.0183492, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "44d47663-a161-4cf0-81dd-d72b5e0b2ec5", "name": "l(r:p1rdt7316lv-p1rlv15632)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a289e26d-2d86-4fdf-942b-881b91ca18eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ccbef4c-6bf7-4892-a3b9-b51aca495137"}}}], "length": {"value": 0.0523363, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3d9c792d-1901-46b8-8dbc-84c2d3351fa6", "name": "l(r:p1rdt7317lv-p1rlv15633)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16c465cf-c4ae-4702-ba6c-0b7704eda764"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce7b60c8-43ee-441d-9f18-5b2722dcc0a7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "a62267fd-b877-4828-8016-462ee6d0d601", "name": "l(r:p1rdt7321lv-p1rlv15640)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c855f7bb-1f33-4c3e-9deb-e3f9c5aba07d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83c2de51-1b04-483c-8ce7-14b9e5e027b9"}}}], "length": {"value": 0.0474361, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c3f2a59a-557e-4560-948b-6a25ec8bf2ef", "name": "l(r:p1rdt7737lv-p1rlv16450)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35be767a-53a1-4fe1-b320-9542dd859d97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5f1e7aa-d93a-4164-8bc0-f920259304a8"}}}], "length": {"value": 0.0142506, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "91de1667-194c-462b-b28f-55a17f4f7220", "name": "l(r:p1rdt7737lv-p1rlv16463)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35be767a-53a1-4fe1-b320-9542dd859d97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9c505d7-3fb9-4eb5-89c6-c9c8da32fd05"}}}], "length": {"value": 0.0227335, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3a01d0fe-40b1-4fb5-91ca-df152fa306f6", "name": "l(r:p1rdt7737lv-p1rlv16507)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35be767a-53a1-4fe1-b320-9542dd859d97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27afe70a-9123-4b0c-9f50-b5355aafcf7a"}}}], "length": {"value": 0.020775, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5c538261-665c-4f36-ba3f-f5e3a08578c7", "name": "l(r:p1rdt7737lv-p1rlv16584)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35be767a-53a1-4fe1-b320-9542dd859d97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "344c6b21-94c9-4912-a19e-69fbae5eed27"}}}], "length": {"value": 0.0280855, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4edf7cf8-7538-4d21-8e74-b279ea148c65", "name": "l(r:p1rdt7753lv-p1rlv16475)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7482f0c-eb85-4e30-a09a-eb9f15bbc22b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d400b1b2-8404-4b80-b110-6f96e000314f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "2037b2b1-5524-4eb7-b64a-da1ecb5f7e62", "name": "l(r:p1rdt7757lv-p1rlv16483)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d343e634-0936-4f21-9e2c-079e19f0dfa1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa6db7ee-126d-4aa9-9733-35ff1c1d5992"}}}], "length": {"value": 0.00228078, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "8d48b987-eaf2-497c-a339-efe11a87bf39", "name": "l(r:p1rdt7757lv-p1rlv16530)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d343e634-0936-4f21-9e2c-079e19f0dfa1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0333a34b-4027-4d9a-9d4a-f867c8a317bc"}}}], "length": {"value": 0.0186713, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8b0bb813-8062-412e-b539-04750931dc13", "name": "l(r:p1rdt7757lv-p1rlv16541)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d343e634-0936-4f21-9e2c-079e19f0dfa1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f7be042-6681-4694-872d-a1cb701016c7"}}}], "length": {"value": 0.0208942, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3d9c040a-bb54-4e9d-81b5-25d6fcbcfc1b", "name": "l(r:p1rdt7791lv-p1rlv16573)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28e5f84f-2fac-4b5c-a669-b16988e4d6ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90d9dbe9-f9c9-4a4e-8ada-cb459778687b"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "af1ad058-7c6a-401b-9fc3-fbfea264ffdf", "name": "l(r:p1rdt7795lv-p1rlv16604)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3959f944-18f5-4daa-a454-3c6bfb7158ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f9ecb3f-8b64-4598-a9d1-d794c6800d33"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "504184a8-1f73-4d48-afa4-2910dbbfa798", "name": "l(r:p1rdt8105lv-p1rlv17239)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b2ec0ba-a854-4631-b97a-4674123d6fe6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba567aae-a893-41d3-8fd1-8357d3cab35d"}}}], "length": {"value": 0.00558108, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b78127ef-db34-49e5-8d34-8d267770eee9", "name": "l(r:p1rdt8105lv-p1rlv17280)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b2ec0ba-a854-4631-b97a-4674123d6fe6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac80cbea-e10a-491a-ba36-06e9fcf74217"}}}], "length": {"value": 0.00558108, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2375fd38-e5df-4013-92a0-781fb802e32a", "name": "l(r:p1rdm17827-p1rlv17246)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3a01639-0851-466b-abc6-adf52342e772"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acfdbe95-2d82-463a-9d1f-6fd2688adf16"}}}], "length": {"value": 0.0396397, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b7c185de-5d32-4bcd-8427-c286259946ea", "name": "l(r:p1rdm17827-p1rdt8111lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b639e55-2e33-4582-bb96-06a9d33a3419"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3a01639-0851-466b-abc6-adf52342e772"}}}], "length": {"value": 0.0160058, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "28b5f84b-cd7d-4034-bdb3-e59c4f80545a", "name": "l(r:p1rdm17828-p1rlv17303)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f70da59-a879-487b-802e-6b7158e425ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04eb7e32-e372-4cb0-94a7-ee418f400bda"}}}], "length": {"value": 0.051430000000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "99397bd6-6958-407d-83b1-af4d43cac71b", "name": "l(r:p1rdm17828-p1rdt8111lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b639e55-2e33-4582-bb96-06a9d33a3419"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f70da59-a879-487b-802e-6b7158e425ca"}}}], "length": {"value": 0.0135199, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0854729a-afef-4d01-8859-67d7f6de1981", "name": "l(r:p1rdt8138lv-p1rlv17291)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dca9b40e-ed8a-4f75-a703-91539f6c3075"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04388b89-16fc-40b3-a060-5bc52032874e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "db220af5-3816-480b-9981-eb1fe35cc177", "name": "l(r:p1rdt8146lv-p1rlv17311)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2bee3961-990e-47ac-b49b-d305f8fe0af8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84ebd9bb-dc50-483d-a3c6-044682d4020c"}}}], "length": {"value": 0.0332245, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0b45d3d6-5c46-46c7-9a97-1f1cf5e43e38", "name": "l(r:p1rdt8167lv-p1rlv17345)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ead5953-70f2-4db2-ba4d-d203c91d85c1"}}}], "length": {"value": 0.0506084, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a4e9e272-25a0-4302-8307-7262bf9ce2f9", "name": "l(r:p1rdt8167lv-p1rlv17357)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf6f74e5-7aa3-4333-bd37-3ce486d54a01"}}}], "length": {"value": 0.0618331, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f0a6e60c-8c24-4e7b-b4ef-7d7ae2b515e9", "name": "l(r:p1rdt8167lv-p1rlv17397)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d38cdffb-41be-48aa-8a03-c6525dd01037"}}}], "length": {"value": 0.0760567, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e1f63203-b54e-40d0-92ec-ae5ba164567c", "name": "l(r:p1rdt8167lv-p1rlv17400)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63177299-2842-4e0d-bf17-7bd2b0afe9a2"}}}], "length": {"value": 0.07573210000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "79e8a7fd-cb8f-4c8b-a89e-4c11077e7b55", "name": "l(r:p1rdt8167lv-p1rlv17405)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b50de14e-9a09-4f61-8998-0979f33b0d0a"}}}], "length": {"value": 0.0505674, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ca4872cb-e641-4360-9f84-ce34923edf34", "name": "l(r:p1rdt8167lv-p1rlv17415)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86b2527b-73c3-41c4-8ac2-7cb0e8bc2a7a"}}}], "length": {"value": 0.061751, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "93491f53-d77b-43a1-a403-c39b07514ecb", "name": "l(r:p1rdt8169lv-p1rlv17347)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6349165a-d47a-4cf4-84f9-df5c5f3a0e98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d98640c6-d8aa-44e4-9ecf-5998152d3f7d"}}}], "length": {"value": 0.0224066, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4ebf0f0a-64e1-4007-b6e9-f21155e3226d", "name": "l(r:p1rdt8169lv-p1rlv17351)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6349165a-d47a-4cf4-84f9-df5c5f3a0e98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2695decb-d268-46b2-8604-9c33dc90518b"}}}], "length": {"value": 0.0609432, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ca6b10dd-667c-47af-be39-98f12b391661", "name": "l(r:p1rdt8169lv-p1rlv17403)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6349165a-d47a-4cf4-84f9-df5c5f3a0e98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d61897a-cdac-4b4a-8812-8a8692a3d958"}}}], "length": {"value": 0.038578400000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "31224941-a62e-42aa-ae90-bd7ccc3abecf", "name": "l(r:p1rdt8174lv-p1rlv17353)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4903e82a-8cfb-406e-b4bf-5e01068419a3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f34e3e4e-bebd-4148-bcc7-cbfbecd73a2f"}}}], "length": {"value": 0.0319504, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "55dc7678-dc68-40c6-ba37-585b326681a7", "name": "l(r:p1rdt8174lv-p1rlv17378)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4903e82a-8cfb-406e-b4bf-5e01068419a3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08709e25-b030-4801-ae00-c4879556d8b1"}}}], "length": {"value": 0.0249412, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d5084996-4e4c-4102-b7a5-52e1080ebde5", "name": "l(r:p1rdt8174lv-p1rlv17383)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4903e82a-8cfb-406e-b4bf-5e01068419a3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e1ad135-904d-47ed-ae74-32b38e1c2f88"}}}], "length": {"value": 0.012372, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ced660f6-d339-46dd-ac3a-27e815f3fec5", "name": "l(r:p1rdt8180lv-p1rlv17361)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8e03b63-853e-4cfe-bf4a-3779b2026637"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c705333f-6f1a-4a76-a02e-eaa859e99b70"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "7ef593a9-0e64-4af1-a4bb-e9b4dc9a4c54", "name": "l(r:p1rdt8195lv-p1rlv17385)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "782d6008-7fec-46b6-9461-9e33b79539d3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e835b413-3307-49ef-ad69-cf18a5ae7cfb"}}}], "length": {"value": 0.014752, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4fa1bae6-7d69-404d-b5a5-f546bb5f877c", "name": "l(r:p1rdt8195lv-p1rlv17387)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "782d6008-7fec-46b6-9461-9e33b79539d3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "55382019-a1a5-40fd-b90a-072af40c2258"}}}], "length": {"value": 0.0249337, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "50184f43-49b4-43eb-ae76-8a7342e55633", "name": "l(r:p1rdt8195lv-p1rlv17391)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "782d6008-7fec-46b6-9461-9e33b79539d3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "169a22de-bb0a-4056-8910-151125c4ff9e"}}}], "length": {"value": 0.04456, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "22e31715-a179-406a-9b84-5870965a7242", "name": "l(r:p1rdt8195lv-p1rlv17407)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "782d6008-7fec-46b6-9461-9e33b79539d3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65de341c-589f-4bf9-a708-26fcc94a6c0a"}}}], "length": {"value": 0.0236267, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "121927ec-fbec-42ba-a8a6-4c6dcc5d1eda", "name": "l(r:p1rdt8195lv-p1rlv17417)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "782d6008-7fec-46b6-9461-9e33b79539d3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67003f0f-6690-469e-82c0-63949ee5241e"}}}], "length": {"value": 0.03781860000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "43975839-0903-4efe-99af-43ae782a4892", "name": "l(r:p1rdt8201lv-p1rlv17394)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76e33e4f-05be-44d1-a503-fed82b4da974"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea560bcb-f930-4f42-ae45-3a60f36fdbb7"}}}], "length": {"value": 0.020193, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ef5666b6-f1d1-4f2d-821e-4d9e2a1463fd", "name": "l(r:p1rdt8201lv-p1rlv17416)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76e33e4f-05be-44d1-a503-fed82b4da974"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64a56527-23a9-4229-aa25-f6a45f2187f4"}}}], "length": {"value": 0.020193, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cd54109f-3a49-4194-850b-5de8de484600", "name": "l(r:p1rdt9055lv-p1rlv19616)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c1f6cd8-cde1-45cc-87ca-1355efa38077"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be1b9922-2426-4726-9e5a-bcd33f444b57"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "c2a1e423-e43a-4b10-bdcb-48a75c970e7c", "name": "l(r:p1rdt9086lv-p1rlv19683)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "afb4c195-8bb6-47d5-88f3-76adb9cda250"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19894180-0890-4585-b4e2-55500af3c41a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "4372152f-0c65-44f9-895a-702b26f19bc7", "name": "l(r:p1rdt16394lv-p1rlv37689)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40b03cbe-470d-493a-854a-900557ac20c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f827fe9e-1ffe-456c-a57b-c3374aef8ad8"}}}], "length": {"value": 0.04723960000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "524c37c2-27e8-46cc-b729-44ebdf5bd414", "name": "l(r:p1rdt16394lv-p1rlv37691)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40b03cbe-470d-493a-854a-900557ac20c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da3cd593-6f05-41ba-9609-f6f1e307e998"}}}], "length": {"value": 0.00410964, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4c9840fc-3d55-44fc-8db0-51dd82d5d450", "name": "l(r:p1rdt16394lv-p1rlv37703)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40b03cbe-470d-493a-854a-900557ac20c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01c9efda-0adf-4932-8f54-2938964371d2"}}}], "length": {"value": 0.0432047, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a76599e2-b880-4448-9ff7-838401b7bccf", "name": "l(r:p1rdt16404lv-p1rlv37710)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38b0bd7c-0898-497f-bb24-4add0fd92932"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38bda697-2888-467e-bab0-62896a62503f"}}}], "length": {"value": 0.0546394, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ffd4c0f2-984f-48ca-ae4a-2d2b8d5eb0bf", "name": "l(r:p1rdt16404lv-p1rlv37732)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38b0bd7c-0898-497f-bb24-4add0fd92932"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d998a0-628e-4009-a6c8-07af906f6d43"}}}], "length": {"value": 0.0546394, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0eeb7dd7-662c-47a3-adc7-5124f65037a5", "name": "l(r:p1rdm37174-p1rlv37776)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58dce206-0571-4a37-b24b-2e674e0c0d3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b24da1e-9a6e-4545-9ad4-a9f0e9675fd1"}}}], "length": {"value": 0.020713, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9d4adf81-a656-46b4-8fdf-bcdddc2d9c0e", "name": "l(r:p1rdm37174-p1rdt16424lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23775c66-0b90-443d-8566-491405876e9d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58dce206-0571-4a37-b24b-2e674e0c0d3b"}}}], "length": {"value": 0.0336785, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2366cce2-64c7-41db-b323-61f0fe2e5dc7", "name": "l(r:p1rdm37175-p1rlv37778)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d21a9584-0fe7-48a6-a46e-ac33e948a471"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5aaed5d-8312-4707-a047-634e433bf49f"}}}], "length": {"value": 0.0194998, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ef783c84-43f7-4a0a-936a-3aaf472a6fb0", "name": "l(r:p1rdm37175-p1rdt16424lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23775c66-0b90-443d-8566-491405876e9d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d21a9584-0fe7-48a6-a46e-ac33e948a471"}}}], "length": {"value": 0.0285662, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8694b9ce-6cbf-4036-a00c-87331245e895", "name": "l(r:p1rdt16427lv-p1rlv37782)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "980376ed-54fd-434c-b58e-0bbd6eaa9954"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d7181ee-ef64-4ded-b619-00ac09d55bf5"}}}], "length": {"value": 0.00573548, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4eae6c4e-f0c8-47ad-9770-7091587932fd", "name": "l(r:p1rdt16603lv-p1rlv38046)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26bc650a-6838-4320-8afa-b8d2f22e96e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10be49a0-301a-4c7e-8ab7-49c14e483079"}}}], "length": {"value": 0.0415295, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "192935c2-108d-4a02-b3ff-d3ac800226fe", "name": "l(r:p1rdt16603lv-p1rlv38047)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26bc650a-6838-4320-8afa-b8d2f22e96e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0935a86b-b9fb-4058-8381-a41f67d6c9dd"}}}], "length": {"value": 0.07748250000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9dfd866d-0648-4a36-9c98-283e673729a5", "name": "l(r:p1rdt16603lv-p1rlv38052)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26bc650a-6838-4320-8afa-b8d2f22e96e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9db6122d-1e51-46ac-9cea-ac436e189cd8"}}}], "length": {"value": 0.0376082, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f4afa825-c031-4375-9b60-796aeee0a73b", "name": "l(r:p1rdt16604lv-p1rlv38048)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d31da07-e20a-4fb8-95f4-d91450395471"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5da7ff68-5f4c-4d56-88fc-7736df03c0bf"}}}], "length": {"value": 0.0117955, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d99baf21-59da-4cbb-9e03-56ef465544aa", "name": "l(r:p1rdt16604lv-p1rlv38050)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d31da07-e20a-4fb8-95f4-d91450395471"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cafc6c03-240d-499d-a3d8-983b554dd007"}}}], "length": {"value": 0.0117955, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5a91da0e-f196-45f7-a32f-1a612d6a008a", "name": "l(r:p1rdt16787lv-p1rlv38414)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4a3b828-bddf-4314-b9a5-03b9dfcd2618"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a25b3511-86cf-404e-944f-273d3f94c05a"}}}], "length": {"value": 0.0187798, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e0ebe0a0-cff4-4adc-a9c9-d828f00e3590", "name": "l(r:p1rdt16787lv-p1rlv38419)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4a3b828-bddf-4314-b9a5-03b9dfcd2618"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6e4595c-0ad9-4501-b86f-c559917d4b86"}}}], "length": {"value": 0.0187798, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "707a4e95-c971-4116-beca-a5ce262f9535", "name": "l(r:p1rdt16790lv-p1rlv38417)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c261090-bc22-4d81-9a9e-75227cd7c99e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "201112bb-3dc7-4a15-9af6-155626ac1ae5"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "cd1a8186-c9d0-42df-b760-b1b95294ef03", "name": "l(r:p1rdt16847lv-p1rlv38535)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1abef1d-4ffc-4696-91ca-e81ac36cce61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0764c32-4f46-473a-9a72-cccc45ae28d7"}}}], "length": {"value": 0.048719200000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4f800f6e-aceb-490a-af1d-44e393867585", "name": "l(r:p1rdt16847lv-p1rlv38536)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1abef1d-4ffc-4696-91ca-e81ac36cce61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ff930f9-63f0-4cab-b74a-3db7eb99f9eb"}}}], "length": {"value": 0.048719200000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b4b5a2d0-160e-402a-b64c-8588848606d6", "name": "l(r:p1rdt16911lv-p1rlv38638)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0df1550a-7e69-42e9-8059-3a36ecb3d253"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a3851f7-2dd3-447b-918f-7a8c954f21d1"}}}], "length": {"value": 0.00340852, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "3b3117b3-95cd-4c2a-824d-0ca04943f253", "name": "l(r:p1rdt383-p1rdt384)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d49257c8-f8eb-4024-9c02-461d18cdd3d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d8cd980-268f-4adb-a6ee-70edf7784542"}}}], "length": {"value": 0.318116, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "93296b51-3b73-4395-b23e-a1fae2d4b519", "name": "l(r:p1rdt383-p1rdt384)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d8cd980-268f-4adb-a6ee-70edf7784542"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7adf2f4b-f0fd-4c53-abcf-d90fe1a2b4c4"}}}], "length": {"value": 0.509093, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c81291a8-f04b-4694-98f0-a6fbd57c43e6", "name": "l(r:p1rdt383-p1rdt7300)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9240d01-bf5d-41ed-8c53-c1f04af1a236"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ac1506-77e9-4b90-ad3d-18be099063a9"}}}], "length": {"value": 0.32156200000000007, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1921e62c-1311-4331-a4a5-2237faa7cb47", "name": "l(r:p1rdt7299-p1rdt7316)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d065da7b-7e88-4e63-a47c-959f4d4c6e1c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6322bf4d-0976-4bae-94c0-f76f83ccb9bf"}}}], "length": {"value": 0.0919841, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bc608943-95fd-47cb-acc2-7387939774bf", "name": "l(r:p1rdt7299-p1rdt7321)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b468be25-1324-46ab-9424-887741ca1134"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d065da7b-7e88-4e63-a47c-959f4d4c6e1c"}}}], "length": {"value": 0.051956600000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "46835e0d-5eec-4eb7-8862-1b1840832c2f", "name": "l(r:p1rdt7308-p1rdt7321)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2e605b4-fe7a-4571-947d-8ae19de627d8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b468be25-1324-46ab-9424-887741ca1134"}}}], "length": {"value": 0.0493128, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c9fea982-3a6d-4605-ba75-13103b955dfa", "name": "l(r:p1rdt7294-p1rdt7308)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a955da2d-e212-4026-b1fb-0021a04ded07"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2e605b4-fe7a-4571-947d-8ae19de627d8"}}}], "length": {"value": 0.06536220000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4ababa0f-34aa-4a8d-9560-2cde2aac808b", "name": "l(r:p1rdt7294-p1rdt7303)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6f24e3a-088a-4d1b-8292-03015289d88e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a955da2d-e212-4026-b1fb-0021a04ded07"}}}], "length": {"value": 0.3131880000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6ccf7fc6-714e-490d-b5be-b1876e6189b0", "name": "l(r:p1rdt7303-p1rdt7317)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48efebbb-c70a-47d3-aae3-0e39088fc455"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e9980c6-3edc-4b4a-be98-cec731419c30"}}}], "length": {"value": 0.34252800000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f7453bad-bc6b-42fc-98f0-7a998cf4dcae", "name": "l(r:p1rdt7303-p1rdt7317)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e9980c6-3edc-4b4a-be98-cec731419c30"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6f24e3a-088a-4d1b-8292-03015289d88e"}}}], "length": {"value": 0.0175612, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "2fbd6f9c-e000-4cd5-97b9-c10833bf3ef6", "name": "l(r:p1rdt7300-p1rdt7317)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05f14a3e-053e-4b65-b962-da7804b9e2c1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48efebbb-c70a-47d3-aae3-0e39088fc455"}}}], "length": {"value": 0.19776300000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "32e79415-33cb-4732-b18b-558714277e5f", "name": "l(r:p1rdt6488-p1rdt7300)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47f8ed28-4bff-47d9-8ffe-4509e9c5b7fc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b96c1e20-68ac-4548-a068-86483c7fa921"}}}], "length": {"value": 0.249926, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a5a2b4bb-a84e-4fbd-8dfa-9a13f2336af4", "name": "l(r:p1rdt6488-p1rdt7300)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b96c1e20-68ac-4548-a068-86483c7fa921"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05f14a3e-053e-4b65-b962-da7804b9e2c1"}}}], "length": {"value": 0.473615, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7a97e04c-3261-43b6-9af9-b42fd68f65e5", "name": "l(r:p1rdt7795-p1rdt9086)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bee93ff6-6ff8-4572-b339-c8e897dac81b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75ee3b24-7407-45ba-94d5-abe187306f13"}}}], "length": {"value": 0.841194, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f85e851f-dc0f-4e6f-a583-3f1ae28d2fe2", "name": "l(r:p1rdt7757-p1rdt7795)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0cd22d3e-1e2a-4a99-9967-b9df95837915"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bee93ff6-6ff8-4572-b339-c8e897dac81b"}}}], "length": {"value": 0.262663, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c80754fc-5960-4d67-a8f1-a5785ee8c97b", "name": "l(r:p1rdt6261-p1rdt6262)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53e5fee4-5a31-448e-8bd0-d8996468d085"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c00c7b1-0aec-4669-9679-cbc1476e0526"}}}], "length": {"value": 0.107372, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6d1cc6e8-e5d0-4689-a499-12aef7ccd279", "name": "l(r:p1rdt6261-p1rdt6262)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c00c7b1-0aec-4669-9679-cbc1476e0526"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf092ec9-ecda-4216-9ac0-0bc035973515"}}}], "length": {"value": 0.0187886, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a9a90a2f-c40a-4110-9de4-a8cb8e889ceb", "name": "l(r:p1rdt6261-p1rdt6263)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53e5fee4-5a31-448e-8bd0-d8996468d085"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c61df077-693e-4e67-aea6-ee60b99406d1"}}}], "length": {"value": 0.228694, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f2d330e4-2f6f-42b5-a13b-cc2a94adeb93", "name": "l(r:p1rdt6261-p1rdt6266)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e22d08f0-2afc-426a-a0c0-6b00cc1103aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cab917a3-5cc2-46d5-9cee-971591841f12"}}}], "length": {"value": 0.435404, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bae0a560-3e11-4f98-b155-63857b58ce6c", "name": "l(r:p1rdt6261-p1rdt6266)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cab917a3-5cc2-46d5-9cee-971591841f12"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53e5fee4-5a31-448e-8bd0-d8996468d085"}}}], "length": {"value": 0.154284, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "38839979-b995-4ab9-be30-6ae67a71c723", "name": "l(r:p1rdt6264-p1rdt6266)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e22d08f0-2afc-426a-a0c0-6b00cc1103aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a03d20d-664a-4e80-abec-a36910787829"}}}], "length": {"value": 0.0739832, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1bd83f42-c21d-47a8-a7a9-1c20e7f83539", "name": "l(r:p1rdt6266-p1rdt6267)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e22d08f0-2afc-426a-a0c0-6b00cc1103aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b6508ce-e51b-4173-8b54-3f3eb7a2cd71"}}}], "length": {"value": 0.325456, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "286e59cc-f63b-468b-8d9a-61393db7e1ee", "name": "l(r:p1rdt6266-p1rdt6267)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b6508ce-e51b-4173-8b54-3f3eb7a2cd71"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a1d9cfa7-0024-4896-a263-2715086f2ad6"}}}], "length": {"value": 0.120044, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0f94cfbd-4761-471c-9562-5e218d822505", "name": "l(r:p1rdt6266-p1rdt8174)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d07105ef-1ba3-4775-aeb4-650b5ea8736e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e22d08f0-2afc-426a-a0c0-6b00cc1103aa"}}}], "length": {"value": 0.262539, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0ea0f6d8-1d8a-446a-b9d5-e7e260e8acd3", "name": "l(r:p1rdt181-p1rdt66)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79d0fee6-369b-4f95-a2d2-cd05232652e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24681ab1-3904-4509-85e6-d9bb1dba4c8e"}}}], "length": {"value": 0.20085399999999998, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "77e9c9e8-25e0-454f-8acc-7bdc292d928a", "name": "l(r:p1rdt253-p1rdt275)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d4e6a87-0313-419f-8feb-7ea3a29f59ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1a85646-be2b-4b15-9c2f-cc603c7e06df"}}}], "length": {"value": 2.31966, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "dfe7b021-ea88-4223-a261-a2701064e836", "name": "l(r:p1rdt275-p1rdt68)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb9e5f0f-8bcf-4019-a786-3f24334e9ae7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8435bee2-05ea-4208-9520-809129624d70"}}}], "length": {"value": 0.43729, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "63205bf8-f4aa-4db4-9485-c23b17d81f7d", "name": "l(r:p1rdt275-p1rdt68)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8435bee2-05ea-4208-9520-809129624d70"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d4e6a87-0313-419f-8feb-7ea3a29f59ae"}}}], "length": {"value": 0.250359, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "be6f7a14-ab8c-4e37-a3ed-5fabff553d05", "name": "l(r:p1rdt280-p1rdt68)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9cb7919-b8bd-46c1-a173-90a5d241c46e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb9e5f0f-8bcf-4019-a786-3f24334e9ae7"}}}], "length": {"value": 0.601429, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "eb7699dc-41c5-4cce-98f5-4ae362b4e94f", "name": "l(r:p1rdt280-p1rdt281)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac745c6f-6e78-4a68-affa-649f91d3aa7c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4425707e-f2b0-419f-828e-a4642ee34b5a"}}}], "length": {"value": 0.0687501, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "72c50a17-a34a-42f4-8b31-08b3bb5f9d75", "name": "l(r:p1rdt280-p1rdt281)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4425707e-f2b0-419f-828e-a4642ee34b5a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9cb7919-b8bd-46c1-a173-90a5d241c46e"}}}], "length": {"value": 1.11596, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "727137fb-8c02-4156-8941-76e9d1959c6a", "name": "l(r:p1rdt181-p1rdt281)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79d0fee6-369b-4f95-a2d2-cd05232652e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac745c6f-6e78-4a68-affa-649f91d3aa7c"}}}], "length": {"value": 0.20523500000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "27e2b305-6b95-45b4-975d-854d614df5dd", "name": "l(r:p1rdt181-p1rdt297)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2fddf29e-6eef-4c60-ad8b-4580440973b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d87f56c0-0a3f-4a94-8f60-1ece461290d0"}}}], "length": {"value": 0.5067780000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "baaa7a29-c4f4-4a42-9496-71615246d038", "name": "l(r:p1rdt3776-p1rdt3777)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "170a2bcb-d7ce-4617-855b-9111b84262ed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f9af980-79c4-4daf-b8fc-44e02953f98b"}}}], "length": {"value": 0.28751, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ab81c681-02cd-4d20-a59a-bf08c0860df2", "name": "l(r:p1rdt270-p1rdt3776)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7eca59ac-01f1-40d7-a0ec-51f355285e01"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6168ebbc-8fd5-49a0-94db-887814eceaba"}}}], "length": {"value": 0.108215, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "07586677-bd64-4204-9ced-d7f05aca7653", "name": "l(r:p1rdt270-p1rdt3776)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6168ebbc-8fd5-49a0-94db-887814eceaba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "170a2bcb-d7ce-4617-855b-9111b84262ed"}}}], "length": {"value": 2.4603700000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "263d110f-a14b-4b87-b223-8da955f62175", "name": "l(r:p1rdt270-p1rdt298)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2c76250-d7ea-4da4-8008-dac1a579e974"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac7c613f-190c-493e-8e89-3ef48e8efdb9"}}}], "length": {"value": 0.28969, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ce9a3964-79b1-4db7-a902-c27cd390c975", "name": "l(r:p1rdt297-p1rdt298)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d32493ec-06be-48ef-959e-779c79c507a3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a468f13-c61f-4c01-aa27-c75fb02030e0"}}}], "length": {"value": 0.19214800000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b7b9dea7-7dc0-419e-b621-97cdac97877f", "name": "l(r:p1rdt297-p1rdt385)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91f76b91-e00a-4a88-8ee8-ec403c2c7d96"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d32493ec-06be-48ef-959e-779c79c507a3"}}}], "length": {"value": 1.01401, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "724c28f1-72e4-4cfa-a5b6-f43bf9859db4", "name": "l(r:p1rdt252-p1rdt385)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22179eaa-fd19-4619-8b31-52bcb36ec683"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91f76b91-e00a-4a88-8ee8-ec403c2c7d96"}}}], "length": {"value": 1.1732, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "026f2218-a9fc-4fcc-8f34-747194feeaa4", "name": "l(r:p1rdt251-p1rdt254)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9c899bc-796a-4e92-88db-6aa11f8777cb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ab802e3-3a0a-413c-8865-e3b3d08e44a8"}}}], "length": {"value": 0.0898381, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0beb9ff2-61e8-46cf-8fd3-44aa828803d1", "name": "l(r:p1rdt258-p1rdt262)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e28087b-b80e-4043-b0f0-0bc82c91f5e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf660777-f77e-4d9b-afff-73a84274c270"}}}], "length": {"value": 0.208153, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "01d3c056-5715-461b-9acc-d66402ab6122", "name": "l(r:p1rdt258-p1rdt261)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "209cebda-044a-42a3-b2f0-fe5b76b80643"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be0fa139-8da7-4cba-9e49-faf4a4814035"}}}], "length": {"value": 0.38624, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f2c4710f-bc68-4564-84af-92a1aa259cb5", "name": "l(r:p1rdt258-p1rdt261)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be0fa139-8da7-4cba-9e49-faf4a4814035"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e28087b-b80e-4043-b0f0-0bc82c91f5e8"}}}], "length": {"value": 0.00488267, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8bb69a39-5b12-4e4f-b027-85e529e0df0b", "name": "l(r:p1rdt261-p1rdt277)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bbe3ac37-aca0-47fd-ac5d-be390cad10ab"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "209cebda-044a-42a3-b2f0-fe5b76b80643"}}}], "length": {"value": 0.627357, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f3609801-4049-4855-a8a0-afaaec9dfde2", "name": "l(r:p1rdt37-p1rdt80)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a2b529c9-4695-42f3-a0e3-69bbb34ff285"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dcbfdc3-b597-4e9e-a86f-4d0ff396ba70"}}}], "length": {"value": 0.120434, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "aa71e0a2-36e9-45a5-8ce4-23aa9fb93fc5", "name": "l(r:p1rdt34-p1rdt77)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a9c4411-f402-464c-ad25-d439b87ef768"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31b06630-2aae-4fe7-9e31-f911c91121cd"}}}], "length": {"value": 0.034869, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4d75f989-6c51-479c-9043-91fcc989f80c", "name": "l(r:p1rdt34-p1rdt38)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b45513a3-8e88-45e9-99d3-6d244c90c256"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a9c4411-f402-464c-ad25-d439b87ef768"}}}], "length": {"value": 0.0394108, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1116ca8a-ac78-49d1-a542-1aa99e1517ef", "name": "l(r:p1rdt31-p1rdt38)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "668d32be-c07a-4387-86a5-e9754af11e9c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b45513a3-8e88-45e9-99d3-6d244c90c256"}}}], "length": {"value": 0.11407100000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "210bf30a-f181-4110-a885-4370b8e42955", "name": "l(r:p1rdt74-p1rdt85)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b82a9a2-b1d1-44eb-a451-946643ef613d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b884fef-8b8f-4ed5-9033-b8177d1c7d70"}}}], "length": {"value": 0.06744590000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4701ebe3-0051-4850-a1be-a674e0d32c1f", "name": "l(r:p1rdt456-p1rdt489)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf205ba7-ac66-4318-aeca-c75eb96cbd1e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cee642e7-12f0-4746-841e-d8cda6fff57e"}}}], "length": {"value": 0.0171007, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7fcd71f7-07a2-4583-92de-d8b76e4fd4fb", "name": "l(r:p1rdt456-p1rdt465)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b092ee09-4c5e-46b5-8ec2-51f99254c220"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf205ba7-ac66-4318-aeca-c75eb96cbd1e"}}}], "length": {"value": 0.0831843, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3d67899c-d0bf-484f-8833-ae3a12e7848e", "name": "l(r:p1rdt46-p1rdt70)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05082892-d69e-4c8f-ba19-c2a627e1c345"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50f3b5f3-3fb5-4fb9-b2e6-b37200af0901"}}}], "length": {"value": 0.0729594, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f96ebf1e-dadb-4961-b8fe-d0177fe34940", "name": "l(r:p1rdt458-p1rdt46)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b61caefd-d5aa-4019-9ac0-aaf8cedc71d0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05082892-d69e-4c8f-ba19-c2a627e1c345"}}}], "length": {"value": 0.139036, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b72cd657-5085-4543-b5f5-8c6a58f68b97", "name": "l(r:p1rdt52-p1rdt72)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2faff95d-f394-427a-9d62-75224f830c9e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6fb1323-f697-4423-a70d-838056200402"}}}], "length": {"value": 0.0184816, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b002135e-3155-4d9a-b8a6-8d2e34cb07e2", "name": "l(r:p1rdt49-p1rdt72)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "137c345c-77cc-4324-bc0e-e0ba896a5f43"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2faff95d-f394-427a-9d62-75224f830c9e"}}}], "length": {"value": 0.141958, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3db69a18-f698-4e11-bb2f-e1e47b900949", "name": "l(r:p1rdt49-p1rdt56)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1d8f5898-7d36-4e40-9980-76d11ef18adb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "137c345c-77cc-4324-bc0e-e0ba896a5f43"}}}], "length": {"value": 0.148385, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "dc672da8-44a3-4894-9c60-5e070b83e7e1", "name": "l(r:p1rdt472-p1rdt56)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fa14b51-a977-4e40-8f9c-28249e576fcf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1d8f5898-7d36-4e40-9980-76d11ef18adb"}}}], "length": {"value": 0.0472436, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c228649f-9ed3-4986-8dac-f0425e9a697a", "name": "l(r:p1rdt458-p1rdt472)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b61caefd-d5aa-4019-9ac0-aaf8cedc71d0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fa14b51-a977-4e40-8f9c-28249e576fcf"}}}], "length": {"value": 0.0781062, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5f1274d2-0fdd-4db3-ba3f-daa46530bbe0", "name": "l(r:p1rdt458-p1rdt468)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04fc215c-7f3e-45e1-a49c-727b0fcdae93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b61caefd-d5aa-4019-9ac0-aaf8cedc71d0"}}}], "length": {"value": 0.11485, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f4afc337-a6c2-4125-b7fe-0719d5e891df", "name": "l(r:p1rdt50-p1rdt53)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c5d8237-0351-4eb2-83e6-13975b37bfa7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7305e2b-0a48-4630-8b8e-c3819f1c9cd1"}}}], "length": {"value": 0.0672176, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "678b9437-c595-43ea-a97d-0017be14cc4d", "name": "l(r:p1rdt50-p1rdt59)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ea7e0bb-bdc5-429a-8889-2f12c94db72e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c5d8237-0351-4eb2-83e6-13975b37bfa7"}}}], "length": {"value": 0.04918, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "60803bca-2ed6-40da-b226-2af544fcb274", "name": "l(r:p1rdt40-p1rdt59)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "577124ac-ea2b-4a60-be47-14b0f5db305e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ea7e0bb-bdc5-429a-8889-2f12c94db72e"}}}], "length": {"value": 0.0516608, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c2559856-65db-4f83-b07d-064dcaedd41f", "name": "l(r:p1rdt40-p1rdt457)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12fef7fc-57f0-4494-becd-4724b84dbbcb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "577124ac-ea2b-4a60-be47-14b0f5db305e"}}}], "length": {"value": 0.0503098, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e0135291-8bce-40e5-95ba-795bc181843a", "name": "l(r:p1rdt457-p1rdt474)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d709af4b-1115-403b-a68d-76c63c93adf2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12fef7fc-57f0-4494-becd-4724b84dbbcb"}}}], "length": {"value": 0.0841745, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b7308a7d-344b-49a7-8d80-685d673ce399", "name": "l(r:p1rdt468-p1rdt474)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5814195b-dd60-4a1e-9af6-b9b84fa4c0c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d709af4b-1115-403b-a68d-76c63c93adf2"}}}], "length": {"value": 0.047055900000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f21f7000-fa58-438d-b295-aeed9c3310fb", "name": "l(r:p1rdt63-p1rdt65)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9397c58-45a1-4ec3-bd84-b4cd5b52dc80"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab2b6727-4d87-4b00-bd49-ba7a6b1b9ce6"}}}], "length": {"value": 0.0933284, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e85cf5e4-69ad-413f-807d-77e3f696eda8", "name": "l(r:p1rdt467-p1rdt65)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ae86125-88c3-44fb-9fe9-1a5d820606f6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9397c58-45a1-4ec3-bd84-b4cd5b52dc80"}}}], "length": {"value": 0.0141041, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a1591c79-b7e3-488b-963c-3d090d44e462", "name": "l(r:p1rdt467-p1rdt469)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48179f57-b0b9-491b-b654-81583768923a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ae86125-88c3-44fb-9fe9-1a5d820606f6"}}}], "length": {"value": 0.045227800000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bf2293fa-d697-40b8-94a8-bbc3360bdc05", "name": "l(r:p1rdt464-p1rdt469)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a634585d-0c70-428e-a3b2-1ec4717d7878"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48179f57-b0b9-491b-b654-81583768923a"}}}], "length": {"value": 0.0950357, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6164d4c1-cfac-48db-b35f-c1fee483f069", "name": "l(r:p1rdt464-p1rdt480)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e5c3d02-1cd2-45e4-90d3-10b135c65f13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a634585d-0c70-428e-a3b2-1ec4717d7878"}}}], "length": {"value": 0.0188143, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "028d1427-12bf-4d80-a0c8-754796fbd8f3", "name": "l(r:p1rdt473-p1rdt480)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76880999-6f79-4fc6-9367-1c419eee26d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e5c3d02-1cd2-45e4-90d3-10b135c65f13"}}}], "length": {"value": 0.100218, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0eac6646-cb23-4f01-9532-2d11c95be7b3", "name": "l(r:p1rdt453-p1rdt473)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1bb6f93-7aed-47d7-99db-7c17352a42b8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76880999-6f79-4fc6-9367-1c419eee26d5"}}}], "length": {"value": 0.0334417, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "550c5f51-4e56-469e-a157-549ea20e8a21", "name": "l(r:p1rdt452-p1rdt453)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d51e6f65-c45c-4f10-a17f-6ef684a0a06c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1bb6f93-7aed-47d7-99db-7c17352a42b8"}}}], "length": {"value": 0.0352317, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "928cf5c6-ff32-4265-a171-caa8f2190066", "name": "l(r:p1rdt452-p1rdt466)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b20fa59a-8573-461a-9c4a-0d47e40d2601"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d51e6f65-c45c-4f10-a17f-6ef684a0a06c"}}}], "length": {"value": 0.13529, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "fd92e905-34f3-437b-8590-4225eebd2e8e", "name": "l(r:p1rdt466-p1rdt478)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64ba6716-89f9-49a4-9793-ba80ae41bcd0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b20fa59a-8573-461a-9c4a-0d47e40d2601"}}}], "length": {"value": 0.100595, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ee3e7c72-665e-47d8-af76-5876a9d9e1c5", "name": "l(r:p1rdt459-p1rdt471)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12d5c579-0570-44db-a751-8eeb92355af9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eed7e6a8-2b4a-4a54-b69a-e3e1a0614213"}}}], "length": {"value": 0.0917334, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5c3199b2-6cca-49c7-aefa-1566475579bf", "name": "l(r:p1rdt459-p1rdt462)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fcfdc5bf-1c87-42e2-8b35-1f7125d3b5ed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12d5c579-0570-44db-a751-8eeb92355af9"}}}], "length": {"value": 0.0703754, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0db2afbf-8d20-4298-92d5-5f6af25ef9eb", "name": "l(r:p1rdt462-p1rdt487)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfb0d992-ab18-4f73-933e-a01ce73ef3b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fcfdc5bf-1c87-42e2-8b35-1f7125d3b5ed"}}}], "length": {"value": 0.0779035, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e9594c65-f9cd-4dd8-801d-a56ca367ddf8", "name": "l(r:p1rdt16787-p1rdt16790)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4774ed1a-85ec-4ca0-8e9a-3b232588fb0c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4bc644c-9875-4846-8b0f-dfa0568de623"}}}], "length": {"value": 0.0992107, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "cadfd571-1a5b-44b9-9fb5-de61bc3fedf8", "name": "l(r:p1rdt16790-p1rdt16911)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4774ed1a-85ec-4ca0-8e9a-3b232588fb0c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d29266e8-ce67-45bf-93d9-710d4684ce0b"}}}], "length": {"value": 0.388046, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "029ca061-b298-4b43-8c5a-f7ac6278b9be", "name": "l(r:p1rdt16790-p1rdt16911)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d29266e8-ce67-45bf-93d9-710d4684ce0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "725fbd98-74ba-4143-8947-da9fdc209889"}}}], "length": {"value": 3.63254, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b2c407c7-c4ae-4f38-879d-6ee603c0a3ac", "name": "l(r:p1rdt16790-p1rdt487)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d53ff9fd-2b16-4026-88fa-2c112d4949c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a1b5b099-df99-4729-a26d-f0882e93136f"}}}], "length": {"value": 0.110567, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f2ae3c18-4521-4101-98d7-6eb006416a16", "name": "l(r:p1rdt16790-p1rdt487)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a1b5b099-df99-4729-a26d-f0882e93136f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4774ed1a-85ec-4ca0-8e9a-3b232588fb0c"}}}], "length": {"value": 5.746810000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9061f19a-d9eb-48b0-9aa6-ee230b7b9499", "name": "l(r:p1rdt484-p1rdt487)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b57b8e2b-62c2-49a0-801d-02cab8092ebd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfb0d992-ab18-4f73-933e-a01ce73ef3b2"}}}], "length": {"value": 0.0512407, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0a5c4a2b-b730-4d42-aa11-f36b01a58a20", "name": "l(r:p1rdt484-p1rdt486)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd2f4b00-6e8b-4faa-a760-7c28f8d36a36"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b57b8e2b-62c2-49a0-801d-02cab8092ebd"}}}], "length": {"value": 0.0914543, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e4317dc5-b30e-44c0-a5fc-e0c630cfe5d6", "name": "l(r:p1rdt482-p1rdt486)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10c2463d-8563-4737-aa7d-e1195c0af9f6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd2f4b00-6e8b-4faa-a760-7c28f8d36a36"}}}], "length": {"value": 0.018752, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ea04bd86-9e92-4818-a4ff-74fa02d6a46e", "name": "l(r:p1rdt482-p1rdt485)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4064b6c-40b4-418b-95ab-4f9bb0363b14"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10c2463d-8563-4737-aa7d-e1195c0af9f6"}}}], "length": {"value": 0.103372, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "256555f0-2f34-42b5-b04a-e8766a7dd987", "name": "l(r:p1rdt476-p1rdt477)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d1eb09d-dff4-4fa3-b96f-ef59b63d6128"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5421facb-0713-404c-97e9-56669fc762b3"}}}], "length": {"value": 0.0550546, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a651515b-87f2-44e9-827e-68ed7e4d130e", "name": "l(r:p1rdt477-p1rdt479)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85acd1fb-6da3-432a-9508-855ca991641b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d1eb09d-dff4-4fa3-b96f-ef59b63d6128"}}}], "length": {"value": 0.06993920000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8f1ebb1d-e621-479d-aa1b-1d0fea5807b5", "name": "l(r:p1rdt454-p1rdt479)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "82459f47-0c6f-4173-8c35-5a9fe5db9713"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85acd1fb-6da3-432a-9508-855ca991641b"}}}], "length": {"value": 0.0357544, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f6e2d9ab-2762-48b9-8da9-cc62bc28adae", "name": "l(r:p1rdt454-p1rdt455)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "183de04a-a665-4112-a912-1df68b61d164"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "82459f47-0c6f-4173-8c35-5a9fe5db9713"}}}], "length": {"value": 0.0689016, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4816e19f-838d-41f2-a889-d1697bb121b3", "name": "l(r:p1rdt455-p1rdt460)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59b616e5-76b8-406c-843f-5c71398af81b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "183de04a-a665-4112-a912-1df68b61d164"}}}], "length": {"value": 0.0565594, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8ca3ee16-bba0-44b3-a3dd-3ea6a58222ea", "name": "l(r:p1rdt460-p1rdt470)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59b616e5-76b8-406c-843f-5c71398af81b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86178159-ccd7-45a3-b711-ac237321d52a"}}}], "length": {"value": 0.106222, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "06b66ecc-6e3f-4117-a516-0557d7bb1370", "name": "l(r:p1rdt460-p1rdt483)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69b5d686-dae0-44c5-a261-f1a73bcb168e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59b616e5-76b8-406c-843f-5c71398af81b"}}}], "length": {"value": 0.106104, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7bdb4c42-40ee-4d95-8b61-c34a1e59a269", "name": "l(r:p1rdt483-p1rdt485)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d899b807-b194-4f65-bad5-a39e8bc61906"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69b5d686-dae0-44c5-a261-f1a73bcb168e"}}}], "length": {"value": 0.19624000000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ca24f954-e522-4093-b3ca-f315003201e2", "name": "l(r:p1rdt279-p1rdt89)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "232adbbb-2715-44be-8db5-ee062ebf4e46"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "416118a8-65b7-4d9e-90a2-454f065bfddb"}}}], "length": {"value": 0.30139, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "49d16b3e-d9c3-46dd-95bb-e5daf8e7a58c", "name": "l(r:p1rdt279-p1rdt89)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "416118a8-65b7-4d9e-90a2-454f065bfddb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac4ad276-90cb-48c0-bfd0-1f2aa0233ce2"}}}], "length": {"value": 0.197349, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a29ed3d7-71e4-416f-abb4-38952e31a0a5", "name": "l(r:p1rdt16424-p1rdt16427)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d50d3e76-470b-47c2-ada2-da944962b322"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "18e3da78-83fc-4b8e-9d45-41adb9b753ad"}}}], "length": {"value": 0.112509, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ecf392c2-a6e6-4d2c-8690-e08a70243f01", "name": "l(r:p1rdt16427-p1rdt16847)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e35a4f7-19c1-4f59-9adc-b267f6088264"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a6382a2-8c21-4cb4-a39b-3f1ac62cc705"}}}], "length": {"value": 0.160318, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b33f1be7-ab62-4068-9cdd-a6b06ddb0dd2", "name": "l(r:p1rdt16427-p1rdt16847)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a6382a2-8c21-4cb4-a39b-3f1ac62cc705"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d50d3e76-470b-47c2-ada2-da944962b322"}}}], "length": {"value": 3.5139, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "81012bf1-6b78-4db4-9e2c-bad624e98440", "name": "l(r:p1rdt16404-p1rdt16847)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61d5dee2-30f8-434d-8c03-76bccff72549"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e35a4f7-19c1-4f59-9adc-b267f6088264"}}}], "length": {"value": 1.15724, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9ae94c4c-3829-4c79-9e4a-a9d47c147dd6", "name": "l(r:p1rdt16394-p1rdt16404)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5b51836-1807-4fab-b877-94a62021569f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61d5dee2-30f8-434d-8c03-76bccff72549"}}}], "length": {"value": 0.518625, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a4046167-8caa-4f89-90f0-2f76d4ead86f", "name": "l(r:p1rdt16394-p1rdt16603)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5a9e0f5-d824-4a76-a4f0-88aab072280e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5b51836-1807-4fab-b877-94a62021569f"}}}], "length": {"value": 0.709035, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3583561b-9771-4681-a564-fd0842692302", "name": "l(r:p1rdt16603-p1rdt16604)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98a946e8-3c8a-49ec-be8a-5610c7fc596c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5a9e0f5-d824-4a76-a4f0-88aab072280e"}}}], "length": {"value": 0.17277, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "906bae77-46ff-4ffe-aa1a-8abca937d44b", "name": "l(r:p1rdt16604-p1rdt257)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ef71bd7-4c82-4296-a6ac-64516ffe96c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "282d8a89-8b14-476b-9e55-b310d8b9396d"}}}], "length": {"value": 0.261511, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "fd814da9-2a6f-4e0b-b2a0-78a6ae1902b8", "name": "l(r:p1rdt209-p1rdt257)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcb27aab-e828-41a6-ad98-d197897a1a69"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fb307f7-3690-4931-999a-4daab4d8c9e5"}}}], "length": {"value": 0.76493, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "071d214f-abee-4f75-a132-0f7658f857bb", "name": "l(r:p1rdt209-p1rdt210)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d782d5e-3960-415c-9e33-6742777a5a0a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcb27aab-e828-41a6-ad98-d197897a1a69"}}}], "length": {"value": 0.184587, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "530e99b6-8a7f-4641-903b-78a595344f17", "name": "l(r:p1rdt211-p1rdt278)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9401940-26a4-40f3-9b9a-5231a5c4e171"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b89bfea1-97cd-41f7-af59-9602a3fc6c06"}}}], "length": {"value": 0.23979600000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d122d673-6fba-4f7f-84e6-34ad0b010b7b", "name": "l(r:p1rdt210-p1rdt211)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d782d5e-3960-415c-9e33-6742777a5a0a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9401940-26a4-40f3-9b9a-5231a5c4e171"}}}], "length": {"value": 0.156188, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "59cdecc0-9e7a-45b1-97e7-6faaaa4f4ffa", "name": "l(r:p1rdt210-p1rdt44)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1be5e34-ad5e-4c78-8067-8e0194c661a4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d782d5e-3960-415c-9e33-6742777a5a0a"}}}], "length": {"value": 1.1888300000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "11448296-bdc4-4e49-9f35-5b5f6fcea1ef", "name": "l(r:p1rdt259-p1rdt44)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0b5743e-c3fd-49c7-879e-9be7d00c480f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33a0a070-9cce-4a82-bd22-24a65f02ef97"}}}], "length": {"value": 0.515436, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "929db262-2207-4a98-873f-3fe8228c418b", "name": "l(r:p1rdt43-p1rdt47)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7728581d-66fc-4e7e-b2b0-85fa02c90523"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ea0531d-530c-4088-86a1-3de96a8938ea"}}}], "length": {"value": 0.165779, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8725d8ec-6b1e-43d3-aac1-c50e038ef687", "name": "l(r:p1rdt48-p1rdt51)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1667a8c6-aeb4-4f22-97b8-62ffefcc12a4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f5cef5c-bcaf-4cd9-afbb-a18bd14dfcd4"}}}], "length": {"value": 0.04269860000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ef4f28ba-8efb-4df9-b243-d434142431d2", "name": "l(r:p1rdt43-p1rdt48)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7728581d-66fc-4e7e-b2b0-85fa02c90523"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1667a8c6-aeb4-4f22-97b8-62ffefcc12a4"}}}], "length": {"value": 0.175272, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5cc6da99-b1cd-4ddb-a42e-7a75db0bf7a7", "name": "l(r:p1rdt43-p1rdt60)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d99e903-3536-4a73-b0d5-ca11f5af6e32"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7728581d-66fc-4e7e-b2b0-85fa02c90523"}}}], "length": {"value": 0.0427769, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6df6cf40-acb9-42fb-99e3-a21ce4101b90", "name": "l(r:p1rdt58-p1rdt60)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a4ccf80-2611-4089-9353-439809aa7854"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d99e903-3536-4a73-b0d5-ca11f5af6e32"}}}], "length": {"value": 0.0448322, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c70146f3-efa7-47d1-9cbb-88314168e430", "name": "l(r:p1rdt58-p1rdt69)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7238345a-1fc7-4f3f-bc8b-88cf7582c75c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a4ccf80-2611-4089-9353-439809aa7854"}}}], "length": {"value": 0.0519836, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "cfb6c001-f792-4ff8-95cf-625dea85b422", "name": "l(r:p1rdt61-p1rdt71)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bcea1fd6-3c51-48af-8528-d3d7bc8e4f01"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "744725a8-af2a-47cf-948f-9d453a932e32"}}}], "length": {"value": 0.0913144, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "98b2bf94-0765-4f57-860d-b02450dd0b62", "name": "l(r:p1rdt150-p1rdt71)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eab6b8c5-ee7a-4779-b5eb-5205dbe5253c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf5b238a-832f-4f45-8a36-2248549e1723"}}}], "length": {"value": 0.0753659, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d510bfdb-9843-422e-8bb1-2f789219abfc", "name": "l(r:p1rdt150-p1rdt71)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf5b238a-832f-4f45-8a36-2248549e1723"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bcea1fd6-3c51-48af-8528-d3d7bc8e4f01"}}}], "length": {"value": 1.27669, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "de6d22bc-1b8f-4f30-bb8b-c8da620b8eba", "name": "l(r:p1rdt374-p1rdt376)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f2a0358-b10d-4b62-8f8d-9a5054fae87d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d425a00d-c0e9-465d-9d9b-af4d64708fba"}}}], "length": {"value": 0.108011, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ff7901c8-0aff-456b-8d81-a1b8d4a2f3b2", "name": "l(r:p1rdt335-p1rdt376)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0de112ae-d04a-4673-98af-0699e4890429"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f2a0358-b10d-4b62-8f8d-9a5054fae87d"}}}], "length": {"value": 0.20898, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5298fbca-8076-473f-8580-b288d0c98374", "name": "l(r:p1rdt415-p1rdt417)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "101c6236-a474-45c8-b065-f5fa045b1107"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "71fa675e-bc20-46f7-b6f1-c88962f9f3cb"}}}], "length": {"value": 0.074738, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e5c8a281-4e52-4e82-9f86-f4ff7e5c363d", "name": "l(r:p1rdt415-p1rdt419)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19116f3c-29ae-4819-ba72-dd0f8afa5078"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "101c6236-a474-45c8-b065-f5fa045b1107"}}}], "length": {"value": 0.232463, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d9a13636-4929-4a92-891e-92960b15b975", "name": "l(r:p1rdt180-p1rdt5098)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9100fbd6-863e-48b2-94ed-aca1ef0947bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5258d4de-be4c-478d-b752-7f4efb0af0a5"}}}], "length": {"value": 0.41780500000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d3025355-e4bb-43e1-8a1f-b9bd5316b188", "name": "l(r:p1rdt6578-p1rdt6584)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9f273a36-c30d-4962-81f4-26f8d20e1cf4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e257530-1fe2-410b-83a1-57789e6ddeda"}}}], "length": {"value": 0.0679586, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9aa5d5e1-1d2f-4b82-a77d-c3f2172ae856", "name": "l(r:p1rdt6584-p1rdt6588)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9f273a36-c30d-4962-81f4-26f8d20e1cf4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1648fe3-a7f9-47aa-b168-d2b56cf220e7"}}}], "length": {"value": 0.0883424, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1eba036d-0e03-407a-85b6-8ba160dad1b3", "name": "l(r:p1rdt6590-p1rdt6591)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1d0a85a-62dc-46d2-bae1-d43d07743a34"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5291ea2b-6990-407b-b8d4-d6868bf37310"}}}], "length": {"value": 0.043231000000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a5bf29ac-89bd-4638-b20b-ed48bd580674", "name": "l(r:p1rdt6584-p1rdt6591)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9f273a36-c30d-4962-81f4-26f8d20e1cf4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1d0a85a-62dc-46d2-bae1-d43d07743a34"}}}], "length": {"value": 0.125784, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f6953e73-a087-4102-a892-1ebe433cef19", "name": "l(r:p1rdt6584-p1rdt6587)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d77add8e-ba22-4b44-9c0b-0bddc251a573"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b918e583-d163-4136-aaf8-62085c7b0c17"}}}], "length": {"value": 0.115903, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f95cb8d3-6bac-4f3f-9987-04072432b638", "name": "l(r:p1rdt6584-p1rdt6587)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b918e583-d163-4136-aaf8-62085c7b0c17"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9f273a36-c30d-4962-81f4-26f8d20e1cf4"}}}], "length": {"value": 0.0307942, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f6679ba4-efdc-4874-8d11-4cf6f748a362", "name": "l(r:p1rdt6580-p1rdt6587)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68298e92-fca3-44e9-9271-f79be47c9c63"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d77add8e-ba22-4b44-9c0b-0bddc251a573"}}}], "length": {"value": 0.286666, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "818206bb-ebe5-4922-a8c2-df51bbeaebf3", "name": "l(r:p1rdt5098-p1rdt6580)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9100fbd6-863e-48b2-94ed-aca1ef0947bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68298e92-fca3-44e9-9271-f79be47c9c63"}}}], "length": {"value": 0.782623, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "de8392a4-82a2-4c6f-9329-507a13f1a963", "name": "l(r:p1rdt5098-p1rdt8169)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb3d775d-8d92-498b-989c-387278ec8e9e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9100fbd6-863e-48b2-94ed-aca1ef0947bd"}}}], "length": {"value": 0.639283, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "76bbbb7c-66cd-4a27-99f1-bb859a6066fd", "name": "l(r:p1rdt414-p1rdt418)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16b7f1e9-3405-4c5f-96c7-d5c08d791907"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3034e62-dd19-4ecb-bb39-6d0566e3a2ef"}}}], "length": {"value": 0.140409, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1a1011d6-d015-42ba-ac6e-da7e2a76d943", "name": "l(r:p1rdt416-p1rdt418)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16b7f1e9-3405-4c5f-96c7-d5c08d791907"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba78164d-d6ae-413b-8d24-067d8d38b28f"}}}], "length": {"value": 0.317261, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ddd205c9-12db-4ebd-8427-ef30fb02d0cd", "name": "l(r:p1rdt416-p1rdt418)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba78164d-d6ae-413b-8d24-067d8d38b28f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d16d5f5e-a376-4e39-a845-d2cde8800da3"}}}], "length": {"value": 0.00719095, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1ef9f953-073c-41dc-9fab-1bb29279ed90", "name": "l(r:p1rdt418-p1rdt8201)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e3d41a7-06a4-460b-aa6c-3a60c8d2de10"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16b7f1e9-3405-4c5f-96c7-d5c08d791907"}}}], "length": {"value": 0.383696, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "52d6e202-09f8-43f8-a1e1-d5a09e7a420b", "name": "l(r:p1rdt8180-p1rdt8201)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63928702-c44a-4e83-9cca-7ce77bdbd2b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e3d41a7-06a4-460b-aa6c-3a60c8d2de10"}}}], "length": {"value": 0.144684, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1b5efc51-00cf-4947-b82a-1d0bc2f4a0ce", "name": "l(r:p1rdt6265-p1rdt9055)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "246ad62e-5a10-4031-94e7-1732f58f1da9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cd9ea283-dbd2-4f38-b298-86a191c99bd2"}}}], "length": {"value": 0.418878, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d2ad08b2-3802-428b-90bc-4116ddde21dc", "name": "l(r:p1rdt6265-p1rdt9055)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cd9ea283-dbd2-4f38-b298-86a191c99bd2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d316c13-77c1-4412-baf9-801f7e5ae407"}}}], "length": {"value": 0.0741307, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6784aa1f-ad7a-4d72-bb32-3a288b673f0f", "name": "l(r:p1rdt5560-p1rdt9055)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30adfcd5-405b-47ea-be54-55c5a47c835f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "708f65d6-b869-4d26-930d-0e669caf4ffb"}}}], "length": {"value": 0.254007, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "fc1f504a-bedc-4016-b92a-65b5bc1fe559", "name": "l(r:p1rdt5560-p1rdt9055)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "708f65d6-b869-4d26-930d-0e669caf4ffb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "246ad62e-5a10-4031-94e7-1732f58f1da9"}}}], "length": {"value": 0.116066, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "660f83ca-a09b-4b56-aa68-675d218b0194", "name": "l(r:p1rdt7737-p1rdt7753)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d2ea25e-3d48-4b1d-9e52-768752de2e09"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d142315b-a247-4a4d-a178-73e3c150a188"}}}], "length": {"value": 0.0669715, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "48e7142e-612f-4100-8d25-23220ea89d75", "name": "l(r:p1rdt7737-p1rdt7791)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4413ca7f-fdd1-484e-a0ba-3ff2447ebfef"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0946738d-95de-4ad6-9d56-c043cb64c0e4"}}}], "length": {"value": 0.249534, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e62453e6-b369-467e-88c6-b611ede7388d", "name": "l(r:p1rdt7737-p1rdt7791)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0946738d-95de-4ad6-9d56-c043cb64c0e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d2ea25e-3d48-4b1d-9e52-768752de2e09"}}}], "length": {"value": 0.0184373, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "37724e03-70aa-4ea1-8b09-81dd8f5d16fa", "name": "l(r:p1rdt7286-p1rdt7791)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02351140-e632-49e2-83e4-7e5bc1c8856a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4413ca7f-fdd1-484e-a0ba-3ff2447ebfef"}}}], "length": {"value": 0.158647, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "62eb02c6-39e5-4a17-8074-8f98b78fcba3", "name": "l(r:p1rdt7286-p1rdt7289)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f8375b7-7bdd-409c-9fa1-5c13bd233364"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02351140-e632-49e2-83e4-7e5bc1c8856a"}}}], "length": {"value": 0.04388460000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "df4ec83d-e66f-4915-88ba-7af7ae387aea", "name": "l(r:p1rdt7289-p1rdt7293)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f8375b7-7bdd-409c-9fa1-5c13bd233364"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4afa9bec-d8da-4449-ab96-9f875bae3c33"}}}], "length": {"value": 0.16261800000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a4c26044-940e-462b-9054-1e0d4b8c36e4", "name": "l(r:p1rdt5568-p1rdt7289)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c83b6ee-20fc-4ca0-a778-44735283afd5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f8375b7-7bdd-409c-9fa1-5c13bd233364"}}}], "length": {"value": 0.600473, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a4279547-718a-4091-8aa8-b7d14015a34a", "name": "l(r:p1rdt5551-p1rdt5568)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8aa126c-9b2b-4ae0-a4fc-36d4201762a0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65eb08cf-6350-410a-88c2-3b318d3a262a"}}}], "length": {"value": 0.0882294, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1369a137-ea26-496f-a49e-07fe1c36db1c"}}}}, {"uuid": "60d3b874-c356-4c2d-8bcd-365734606fc3", "name": "l(r:p1rdt5551-p1rdt5568)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65eb08cf-6350-410a-88c2-3b318d3a262a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64aba8d5-1dd3-4741-a8ba-26801e275ba8"}}}], "length": {"value": 0.0161184, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a6b9e998-dc46-46e3-b86b-5d83295608dd", "name": "l(r:p1rdt5548-p1rdt5577)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c49b671-0b2b-43c9-bcb5-21c7b7e716ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fead5749-3ba7-4ead-a604-e8adbd18f8c2"}}}], "length": {"value": 0.160305, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1369a137-ea26-496f-a49e-07fe1c36db1c"}}}}, {"uuid": "7ddab2ca-bfb1-4594-b119-011f70f0dd90", "name": "l(r:p1rdt182-p1rdt304)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c51ccb17-eed6-4ce0-b839-e7b26001fe3e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08e378d4-4ca6-4c9e-93fa-36ff87a3cf0f"}}}], "length": {"value": 0.7293, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "129d30ae-597e-45cf-b893-7a0bf9dba703", "name": "l(r:p1rdt304-p1rdt305)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b936973-54dc-41e7-a413-8932c31f0793"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c51ccb17-eed6-4ce0-b839-e7b26001fe3e"}}}], "length": {"value": 0.171066, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "86281a7e-9023-4f94-a293-57e7d50db505", "name": "l(r:p1rdt303-p1rdt305)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9672c49b-8316-4907-b204-7505483210b0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b936973-54dc-41e7-a413-8932c31f0793"}}}], "length": {"value": 0.3440750000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "312c6354-e82f-404e-8e44-2dcf1c65f8bf", "name": "l(r:p1rdt177-p1rdt303)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ad84ef4-4dcc-42f7-99ed-b8d21cebc465"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9672c49b-8316-4907-b204-7505483210b0"}}}], "length": {"value": 0.47439500000000007, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f5774d9c-24b9-411c-a015-e6e4b59caef7", "name": "l(r:p1rdt178-p1rdt306)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57a78c71-e5a8-4dfd-8359-e368b7b198fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6912a245-ac1c-4ddd-b021-3bc35cbbe2c5"}}}], "length": {"value": 1.21943, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c7cb6ba7-cba6-40f8-a51e-07fb728cc8a3", "name": "l(r:p1rdt177-p1rdt306)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ad84ef4-4dcc-42f7-99ed-b8d21cebc465"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57a78c71-e5a8-4dfd-8359-e368b7b198fa"}}}], "length": {"value": 0.644981, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0217c83c-f2af-4c1c-ac7f-0a81411e1e63", "name": "l(r:p1rdt177-p1rdt8105)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3f91816-7c3f-4fc7-98a5-6dee55e52e9f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ad84ef4-4dcc-42f7-99ed-b8d21cebc465"}}}], "length": {"value": 1.4039100000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "2ed246a3-dfad-450b-b7f1-ab6f298571c4", "name": "l(r:p1rdt8105-p1rdt8111)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2c69fef-4afb-4bb3-9828-096b812de54a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37229b7c-80a2-4d01-af6a-818bdfcc1f54"}}}], "length": {"value": 0.0910676, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "12928856-aaca-4156-8f34-04878d8ad992", "name": "l(r:p1rdt8105-p1rdt8111)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37229b7c-80a2-4d01-af6a-818bdfcc1f54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3f91816-7c3f-4fc7-98a5-6dee55e52e9f"}}}], "length": {"value": 0.186172, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "aa0b22a4-6d2d-44c3-bf03-9f5e189ed04f", "name": "l(r:p1rdt8111-p1rdt8146)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2c69fef-4afb-4bb3-9828-096b812de54a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc34073b-94f6-4c75-8144-8f624bac9cc7"}}}], "length": {"value": 0.0135199, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bd0c3d35-c8cb-4701-b32e-a31567ad572d", "name": "l(r:p1rdt8111-p1rdt8138)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9929e0d4-3e33-4f5f-b718-6a629cc52242"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3a54311-da27-45d7-95c3-eee07761fbe4"}}}], "length": {"value": 0.198155, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "817adbcf-58d7-4cf2-b4cb-c18d1bc0c604", "name": "l(r:p1rdt8111-p1rdt8138)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3a54311-da27-45d7-95c3-eee07761fbe4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2c69fef-4afb-4bb3-9828-096b812de54a"}}}], "length": {"value": 0.00299557, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "95236d9f-791c-4a01-a0fd-cb767ec941fa", "name": "l(r:p1rdt251-p1rdt252)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b801037a-e1bb-4c5c-8d18-ed285c8c1d3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69b2ee46-ab5f-48c8-a26b-170ed2b57fcb"}}}], "length": {"value": 0.0455935, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "c1ec8649-6347-41c8-8e9c-1a2e0a37841e", "name": "l(r:p1rdt251-p1rdt446)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3dfe357-889d-42e0-a59a-821c9f843456"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b801037a-e1bb-4c5c-8d18-ed285c8c1d3b"}}}], "length": {"value": 0.620095, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "02b836f0-26df-4939-85a9-506b1779e82b", "name": "l(r:p1rdt468-p1rdt481)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cf3136f-6dbe-4ed7-b9cb-e9f73b191f76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a180b972-cf0e-4a2e-9bcf-a0ad90bb3d83"}}}], "length": {"value": 0.100395, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "dcd73329-a55d-4e12-a3ff-f205c33136f3", "name": "l(r:p1rdt475-p1rdt481)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c39140c6-8892-480a-81b9-738c67ed1591"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cf3136f-6dbe-4ed7-b9cb-e9f73b191f76"}}}], "length": {"value": 0.0369015, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "a299d137-b589-4bab-9836-867f1cdfec55", "name": "l(r:p1rdt461-p1rdt475)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc35f44e-d8d9-41d0-b014-caa3d8d7a91e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c39140c6-8892-480a-81b9-738c67ed1591"}}}], "length": {"value": 0.0590418, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "cc87ca48-40d2-40fa-9407-459ef56a38b8", "name": "l(r:p1rdt461-p1rdt478)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eba354c-f4bf-4c49-a8ad-998ab9489e5a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc35f44e-d8d9-41d0-b014-caa3d8d7a91e"}}}], "length": {"value": 0.0960031, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d6d87a15-b966-4e10-bace-11ae16b68c35", "name": "l(r:p1rdt465-p1rdt478)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a94f7afe-e8b0-4b24-8196-6b05e98c3830"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eba354c-f4bf-4c49-a8ad-998ab9489e5a"}}}], "length": {"value": 0.0203603, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "485b7ea4-6076-4866-bc63-7950ab5f04be", "name": "l(r:p1rdt465-p1rdt488)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fa474a3-1d6b-454b-9170-6a8d13789c43"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a94f7afe-e8b0-4b24-8196-6b05e98c3830"}}}], "length": {"value": 0.148866, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "c56be5eb-6989-4184-86ff-3b60dff1d2be", "name": "l(r:p1rdt463-p1rdt488)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7637cfdb-6a14-4313-95d4-e25beba178f3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fa474a3-1d6b-454b-9170-6a8d13789c43"}}}], "length": {"value": 0.0269677, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "85776a35-68a0-48b2-b32c-4fcf63f765bf", "name": "l(r:p1rdt463-p1rdt82)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7627cbc6-c54a-432b-8cba-59e448f6d45a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7637cfdb-6a14-4313-95d4-e25beba178f3"}}}], "length": {"value": 0.14966800000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "95bc8f10-ed30-43b9-88b7-71e259b40cd0", "name": "l(r:p1rdt78-p1rdt82)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36bfd1f1-80ca-4b7d-a68b-9aa77ceff96e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7627cbc6-c54a-432b-8cba-59e448f6d45a"}}}], "length": {"value": 0.0637409, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "9c2f5d3e-aed7-46b7-a9db-8653f9ca9dab", "name": "l(r:p1rdt78-p1rdt85)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fc415bc-f457-4e9f-bbd4-783a71b67ad6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36bfd1f1-80ca-4b7d-a68b-9aa77ceff96e"}}}], "length": {"value": 0.0375885, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "6a1cad6b-2cac-431d-af4c-21b2a59172a9", "name": "l(r:p1rdt81-p1rdt85)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "063e25be-2abb-49ae-b459-ddd08ba93bb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fc415bc-f457-4e9f-bbd4-783a71b67ad6"}}}], "length": {"value": 0.0219108, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "90683555-cb96-4ee2-8b94-86a64832f1b8", "name": "l(r:p1rdt79-p1rdt81)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b32c9763-ddff-435b-a28c-8f65111c6cb2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "063e25be-2abb-49ae-b459-ddd08ba93bb3"}}}], "length": {"value": 0.0220447, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "372cf68c-8148-4394-a412-526fb4273f82", "name": "l(r:p1rdt76-p1rdt79)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfbb212a-9882-4468-86ac-578c93fde1d8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b32c9763-ddff-435b-a28c-8f65111c6cb2"}}}], "length": {"value": 0.0442698, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "24ae7f1a-6a8a-4a84-aed9-7438bb1bec6e", "name": "l(r:p1rdt31-p1rdt76)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7c543753-fa26-41df-b7a6-3664395c0d45"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfbb212a-9882-4468-86ac-578c93fde1d8"}}}], "length": {"value": 0.117156, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f53f5aae-c274-43c4-b7af-d3041298dfff", "name": "l(r:p1rdt31-p1rdt36)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8dcdfef-b40e-4f1c-9b7c-e84846f68c5a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7c543753-fa26-41df-b7a6-3664395c0d45"}}}], "length": {"value": 0.088569, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "e93867c8-7f0e-49a3-8db2-3f7907cc4bff", "name": "l(r:p1rdt32-p1rdt36)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "834e959c-8ee6-4fff-b1fc-54c20fc0f20b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8dcdfef-b40e-4f1c-9b7c-e84846f68c5a"}}}], "length": {"value": 0.10601200000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "5231e2a7-fda4-48de-a8e5-a4f8a504694d", "name": "l(r:p1rdt234-p1rdt32)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80331f15-8b31-454c-a289-49cb79923252"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "834e959c-8ee6-4fff-b1fc-54c20fc0f20b"}}}], "length": {"value": 0.0518824, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "198b7f01-439d-4fea-bb64-8e615b1d0219", "name": "l(r:p1rdt233-p1rdt485)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f5ed5d5-93fc-4f3c-a78b-df7019863b67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "445f61a4-8045-4558-a3c1-bb44336737ec"}}}], "length": {"value": 0.123436, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "c8e84a6d-4476-4110-8a87-5bff5dfd82d6", "name": "l(r:p1rdt233-p1rdt236)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "190d6c51-94b6-462e-8fee-cce57f1ab66d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f5ed5d5-93fc-4f3c-a78b-df7019863b67"}}}], "length": {"value": 0.0731224, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "ac72dac2-d88d-478e-9c53-c5d07d08999e", "name": "l(r:p1rdt234-p1rdt236)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80331f15-8b31-454c-a289-49cb79923252"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "190d6c51-94b6-462e-8fee-cce57f1ab66d"}}}], "length": {"value": 0.175361, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "bff96efe-7ad7-4117-8d5e-ed34b5e1b0d0", "name": "l(r:p1rdt234-p1rdt235)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14b85850-d83e-4a5e-83c3-ccb485bb85aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80331f15-8b31-454c-a289-49cb79923252"}}}], "length": {"value": 0.10401900000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "4b67aeb5-bf41-404b-b4d6-ed2773d5f4a9", "name": "l(r:p1rdt235-p1rdt30)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fa95a19-0e0a-49b3-bb86-7103fbaa4110"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14b85850-d83e-4a5e-83c3-ccb485bb85aa"}}}], "length": {"value": 0.07237510000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "9e0dc484-5292-4398-b046-2bb0b8595c8c", "name": "l(r:p1rdt30-p1rdt35)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "edc22f66-e919-448e-b990-76033c281d43"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fa95a19-0e0a-49b3-bb86-7103fbaa4110"}}}], "length": {"value": 0.108408, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "57e13003-4b6c-451f-b816-8653b0a58096", "name": "l(r:p1rdt35-p1rdt84)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e9f4b13-5fb5-46b2-9258-83582d47d61a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "edc22f66-e919-448e-b990-76033c281d43"}}}], "length": {"value": 0.0706611, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "30145750-aaff-48a3-b83b-9b27874f2bc3", "name": "l(r:p1rdt33-p1rdt84)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f55e4012-a11d-4883-baac-9c013aff6058"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e9f4b13-5fb5-46b2-9258-83582d47d61a"}}}], "length": {"value": 0.08205580000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f055d7d6-9d6d-4aa0-955c-8987e1322223", "name": "l(r:p1rdt33-p1rdt39)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a01c83d1-4adb-4b2a-8de3-441d7c1dd054"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f55e4012-a11d-4883-baac-9c013aff6058"}}}], "length": {"value": 0.0532669, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "ab5f4002-be54-4c6e-8532-bd6c2fa76205", "name": "l(r:p1rdt39-p1rdt73)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc531967-1a7b-4424-83ee-e1131c6fd94c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a01c83d1-4adb-4b2a-8de3-441d7c1dd054"}}}], "length": {"value": 0.0177535, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "664a630b-6756-439e-a71a-12b73095c4bf", "name": "l(r:p1rdt73-p1rdt75)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "510ea93c-7dd1-4fa3-ba3f-6c362856c7c1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc531967-1a7b-4424-83ee-e1131c6fd94c"}}}], "length": {"value": 0.0510053, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "17c999b3-2206-4299-a8c6-d725bd804b3c", "name": "l(r:p1rdt75-p1rdt83)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aa0b7c2-9d55-4faf-8778-76a6f23bcf3e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "510ea93c-7dd1-4fa3-ba3f-6c362856c7c1"}}}], "length": {"value": 0.0608389, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "a03c0ec0-e778-49bd-babf-57f483e5f78d", "name": "l(r:p1rdt80-p1rdt83)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b03f8e29-a5b2-4bed-b68c-219276674b6a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aa0b7c2-9d55-4faf-8778-76a6f23bcf3e"}}}], "length": {"value": 0.10093, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "8435eda2-aebc-4043-8961-853e603285bf", "name": "l(r:p1rdt263-p1rdt80)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e26e5dc-8c98-4fcd-b125-3265eb00f3f2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b03f8e29-a5b2-4bed-b68c-219276674b6a"}}}], "length": {"value": 0.7842920000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "b8f9d0e5-0e06-4d03-a44d-6fbdf10da8a4", "name": "l(r:p1rdt263-p1rdt277)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "add5e39f-f02e-4a61-a156-d5721cec25d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e26e5dc-8c98-4fcd-b125-3265eb00f3f2"}}}], "length": {"value": 0.731992, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "2f9e0bfb-0ba5-4693-8dbb-8500785d1fa7", "name": "l(r:p1rdt276-p1rdt277)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "186ffdfe-2346-4218-bd6b-b813ea6b3b62"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "add5e39f-f02e-4a61-a156-d5721cec25d5"}}}], "length": {"value": 0.376236, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "095deedb-f5aa-4b88-8ec2-fa9270de8eee", "name": "l(r:p1rdt44-p1rdt69)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9396562e-4f87-4e04-b248-502b851fe19e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1bf1493-fb0d-40b4-8953-42e851a128d1"}}}], "length": {"value": 0.096072, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "16c1200d-d591-4bd8-aa0f-4d52544f6dca", "name": "l(r:p1rdt44-p1rdt69)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1bf1493-fb0d-40b4-8953-42e851a128d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d9ee2ff-e2bc-4d76-b173-5ba5cc48c9b3"}}}], "length": {"value": 0.103033, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d2e808c0-fed6-463f-887f-0e7be56eabd4", "name": "l(r:p1rdt41-p1rdt69)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5b5b3ae-f657-4fd4-a311-ab1dbe9d749e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9396562e-4f87-4e04-b248-502b851fe19e"}}}], "length": {"value": 0.0379066, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "ccf449d9-5f73-457c-ad76-1fc3f639c69d", "name": "l(r:p1rdt41-p1rdt54)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a898f4c-f522-4e69-be4a-e935e339e011"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5b5b3ae-f657-4fd4-a311-ab1dbe9d749e"}}}], "length": {"value": 0.0700668, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "0bf9bcaf-d009-493b-b258-a20b48a817ea", "name": "l(r:p1rdt42-p1rdt54)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a778171c-22a1-4320-9e3c-43888d734e34"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a898f4c-f522-4e69-be4a-e935e339e011"}}}], "length": {"value": 0.0819124, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "fe298b54-0758-4c2f-937f-b4e520788b5d", "name": "l(r:p1rdt42-p1rdt45)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29a79372-9c75-4a9c-81df-a7491b87e58a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a778171c-22a1-4320-9e3c-43888d734e34"}}}], "length": {"value": 0.109393, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "7752518c-dbd5-4bcf-98ba-736e959ee9fd", "name": "l(r:p1rdt150-p1rdt45)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12451cbc-eb14-4814-b274-12eb2241c78a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "666bb367-692a-4127-8f77-d86d651768a1"}}}], "length": {"value": 0.181242, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "1af5f53b-c460-4041-bb80-361236411275", "name": "l(r:p1rdt150-p1rdt45)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "666bb367-692a-4127-8f77-d86d651768a1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29a79372-9c75-4a9c-81df-a7491b87e58a"}}}], "length": {"value": 1.27197, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "9f74db70-41c8-4e3a-954c-bbda4ce07e86", "name": "l(r:p1rdt150-p1rdt260)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba0ef4a3-43ba-469b-8ce8-ca7a5a984071"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e885b3e5-18fb-4454-b8e7-d82b4c72f6e8"}}}], "length": {"value": 0.105488, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "43084528-6f58-47a7-8115-80e604d313d3", "name": "l(r:p1rdt150-p1rdt260)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e885b3e5-18fb-4454-b8e7-d82b4c72f6e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12451cbc-eb14-4814-b274-12eb2241c78a"}}}], "length": {"value": 0.49255100000000007, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "19fa5caf-ed6f-48b1-aef3-26ccfa1abc3b", "name": "l(r:p1rdt260-p1rdt279)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "153bb615-5ee5-4eec-bcf7-94ea0098aeb6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba0ef4a3-43ba-469b-8ce8-ca7a5a984071"}}}], "length": {"value": 0.693281, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "b5f6404e-7ee0-44ba-83b2-4d2a8b780d6d", "name": "l(r:p1rdt276-p1rdt279)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7140d97e-416e-47ec-9f86-46ad6f9abece"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "153bb615-5ee5-4eec-bcf7-94ea0098aeb6"}}}], "length": {"value": 0.296948, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "a22eecf7-0b6c-4b67-b1b6-ef07cf773782", "name": "l(r:p1rdt237-p1rdt276)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3ca9bee-26b0-4ef4-8555-6494ffdd6a17"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "767b59ef-ecd9-4b17-8233-2033a02b2971"}}}], "length": {"value": 0.558882, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "3aa27888-757a-4ade-a479-17348bb56293", "name": "l(r:p1rdt237-p1rdt276)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "767b59ef-ecd9-4b17-8233-2033a02b2971"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "186ffdfe-2346-4218-bd6b-b813ea6b3b62"}}}], "length": {"value": 0.599014, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "3494f392-4b57-4668-b618-de109c41f74b", "name": "l(r:p1rdt237-p1rdt445)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11571d26-573f-49f7-99fd-828dde97afd8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8c8b8f8-7a41-4d16-b509-2d7c7af9509d"}}}], "length": {"value": 0.477235, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "23768e60-635b-4d3f-be8d-50fde874d64a", "name": "l(r:p1rdt438-p1rdt445)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10620dcc-049c-4417-b4ac-922a56c0d4a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11571d26-573f-49f7-99fd-828dde97afd8"}}}], "length": {"value": 0.109204, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "418c0e4f-5a25-445f-91f1-8a7745ad0c0b", "name": "l(r:p1rdt438-p1rdt446)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3dfe357-889d-42e0-a59a-821c9f843456"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10620dcc-049c-4417-b4ac-922a56c0d4a2"}}}], "length": {"value": 0.05910800000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "0e0c3e54-806e-4c0f-9753-303f0f99e48d", "name": "l(r:p1rdt28-p1rdt446)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e71eb2d5-cd10-498d-b9eb-ae337b2f8af6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3dfe357-889d-42e0-a59a-821c9f843456"}}}], "length": {"value": 2.20796, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d440b633-33ea-4a79-a563-f95e7e886d44", "name": "l(r:p1rdt28-p1rdt29)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b238dc5-7d8e-4b2d-8449-4dc212d7d227"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e71eb2d5-cd10-498d-b9eb-ae337b2f8af6"}}}], "length": {"value": 0.24769, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "60bac6f6-9fdd-4815-92c7-20ba11b7d04a", "name": "l(r:p1rdt29-p1rdt335)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b07c4a6-39a7-4521-bce7-3f1ca0ff4a66"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b238dc5-7d8e-4b2d-8449-4dc212d7d227"}}}], "length": {"value": 0.899533, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "ad61cfe0-a656-43cd-97b6-04704f1d3e5b", "name": "l(r:p1rdt335-p1rdt419)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2efeaf5-2055-4718-a064-7c5e00b7d87d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b07c4a6-39a7-4521-bce7-3f1ca0ff4a66"}}}], "length": {"value": 1.90653, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "e66e4d18-0d3a-4652-bd28-391e4e42b5ca", "name": "l(r:p1rdt419-p1rdt420)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4cf05060-0a39-49a9-a761-79fb136e2965"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81cfd2a2-295c-4b73-abba-05ffee810523"}}}], "length": {"value": 0.238058, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "e475a674-9e0e-438b-956a-b0c948b066b6", "name": "l(r:p1rdt420-p1rdt8167)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eb3d4eb-71fc-46f3-b588-d223568c411c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4cf05060-0a39-49a9-a761-79fb136e2965"}}}], "length": {"value": 0.4863970000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "cc58970e-64bc-4597-914e-37cb30e8ffc9", "name": "l(r:p1rdt8167-p1rdt8180)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c93a476-4ad5-41cd-a07b-e2ccc9ef2c3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eb3d4eb-71fc-46f3-b588-d223568c411c"}}}], "length": {"value": 0.163613, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "62e99707-ce49-47b4-a983-1959eeb7a76e", "name": "l(r:p1rdt8169-p1rdt8180)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c93a476-4ad5-41cd-a07b-e2ccc9ef2c3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6bdb2cf-9373-4d56-a5f9-cb8fa9c67e55"}}}], "length": {"value": 0.222344, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "a780ffe2-7718-4b83-b86a-e0fe3fb9d703", "name": "l(r:p1rdt8174-p1rdt8180)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "498a07ee-e12b-459a-a01f-f663a4a8428a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c93a476-4ad5-41cd-a07b-e2ccc9ef2c3b"}}}], "length": {"value": 0.527921, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "6617344b-9ba8-444d-bb97-2a58fedb9fbd", "name": "l(r:p1rdt8174-p1rdt8195)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8997dae6-8970-4762-98e9-0617375633d6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b0f9433-e0a3-458a-8687-c9cf38d0bbb3"}}}], "length": {"value": 0.115815, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "84d5b120-0d32-4f1b-a36d-b5c13c2111a5", "name": "l(r:p1rdt7757-p1rdt8195)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "081feb5c-d5d5-405e-85d4-f1dd0916fc3d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8997dae6-8970-4762-98e9-0617375633d6"}}}], "length": {"value": 0.279303, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "9ddeb1c5-3ca3-4e2d-9c80-477ec8adb6be", "name": "l(r:p1rdt5560-p1rdt7757)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68117bef-16c5-40c9-9356-76ef5c056650"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b64b7bd6-06e4-45f7-b987-efc7d09b91f8"}}}], "length": {"value": 0.322295, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "1e9bf254-9c79-4ea5-8fad-7bda32329ae5", "name": "l(r:p1rdt5560-p1rdt7757)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b64b7bd6-06e4-45f7-b987-efc7d09b91f8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "081feb5c-d5d5-405e-85d4-f1dd0916fc3d"}}}], "length": {"value": 0.349419, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "15fcd358-cd82-4f30-b9a7-7166929792fe", "name": "l(r:p1rdt5560-p1rdt5564)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8444c9ea-ff7a-4b0a-9ea6-9c18770565cb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68117bef-16c5-40c9-9356-76ef5c056650"}}}], "length": {"value": 0.08906480000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "224b5f84-1923-4354-9d26-d73c5031bd42", "name": "l(r:p1rdt5563-p1rdt5564)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad24f98d-f022-4e62-b80b-426052810759"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8444c9ea-ff7a-4b0a-9ea6-9c18770565cb"}}}], "length": {"value": 0.0604798, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "33a61b6a-9e2b-42e9-ad56-90f1398207e6", "name": "l(r:p1rdt5557-p1rdt5563)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c94489ed-4399-4dab-bab6-02b79f240f63"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fbc31b75-f942-4bae-8712-f1666d8b7f26"}}}], "length": {"value": 0.0599682, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "20b4ef91-8e73-4465-8325-4d24a3b897d5", "name": "l(r:p1rdt5557-p1rdt5565)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "efe7243f-340b-4114-be7c-f7494e78384f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bfe92e2e-285d-4c58-8e0b-a462dd73fa41"}}}], "length": {"value": 0.058444, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "6efab38c-c3e9-4312-b685-21a2d96b021e", "name": "l(r:p1rdt5561-p1rdt5565)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8bd0860f-2b3e-4c90-a571-cfc6aa649e5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bebca5d7-2d4f-4655-a965-9faafd7a8125"}}}], "length": {"value": 0.047072, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "029915e5-6ffa-4e8a-992f-299338154773", "name": "l(r:p1rdt5551-p1rdt5561)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27ab530f-a58e-4113-80f6-63f768910204"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf97a458-469e-4609-bb33-97454e7c2b68"}}}], "length": {"value": 0.0283038, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "f198382a-0a0f-4e03-9ae9-b2efa019c2ca", "name": "l(r:p1rdt5548-p1rdt5551)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d447cf8-7b2b-45f1-8084-6fe4897e1853"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ec70f12-a676-48cd-b626-34f8d7f6a5bf"}}}], "length": {"value": 0.0368985, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "a4b33341-bd57-4d7b-b4aa-f10eebfda207", "name": "l(r:p1rdt5548-p1rdt5566)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10f43169-4b4b-4dbe-8f09-af72d427d6c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23163dba-070c-435c-bb90-77be7ded002a"}}}], "length": {"value": 0.0390774, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "40c04881-ef90-4bbb-9776-4086b7596654", "name": "l(r:p1rdt5566-p1rdt5574)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf619f04-1fa5-4be7-8a76-669b79436d3e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c264e6de-a898-421d-a2fe-ce6548aa477e"}}}], "length": {"value": 0.00976661, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "3d33cc3f-87f4-4ed0-91cc-87931b9584c8", "name": "l(r:p1rdt5574-p1rdt8138)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17b633c6-214d-4428-bded-df737f50ffb6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c8fd701-7842-49c1-b630-7ae1ad49739f"}}}], "length": {"value": 0.295682, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "596de436-8b70-4b86-90d6-c950c609a1a1", "name": "l(r:p1rdt5574-p1rdt8138)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c8fd701-7842-49c1-b630-7ae1ad49739f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9906676-e9b9-4d51-b1c2-a6b6fe187faa"}}}], "length": {"value": 0.00299767, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "1e2f5da7-2523-420f-9a3f-8207dba32215", "name": "l(r:p1rdt6488-p1rdt8138)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63b2f1e6-5e15-4433-85ee-ff7bb7218b96"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "548ba541-a511-486c-876c-c841a6e482af"}}}], "length": {"value": 0.512556, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "05321a30-75f0-40c2-b4b8-86477a6638ba", "name": "l(r:p1rdt6488-p1rdt8138)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "548ba541-a511-486c-876c-c841a6e482af"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17b633c6-214d-4428-bded-df737f50ffb6"}}}], "length": {"value": 1.64392, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "0aea12b8-2186-4836-85d6-b58d4342e6b6", "name": "l(r:p1rdt6488-p1rhs7_1247)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ed5e3889-e8c8-4215-adb8-9880f8937da5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63b2f1e6-5e15-4433-85ee-ff7bb7218b96"}}}], "length": {"value": 0.640605, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "56c3525d-82f8-42be-a65c-cf7759d85f2d", "name": "l(r:p1rdt5551lv-p1rlv11506)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9dec144-ef2e-44fe-990a-c9d70b740410"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "82988650-787d-41de-bca7-4f3c08ccad15"}}}], "length": {"value": 0.0327608, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "5c2ec73d-3368-4c1c-9ef2-795598c70ec1", "name": "l(r:p1rdt5565lv-p1rlv11522)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60dc1291-a843-4abf-bfc6-ff8afc8c0b98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "176b348f-9ecf-4a82-bdf9-f2e5d5a07af7"}}}], "length": {"value": 0.05525650000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "6dacb7f0-677a-488e-9ecc-948c66479101", "name": "l(r:p1rdt5563lv-p1rlv11520)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a150dd3-61a4-4df9-90e2-6c72f80af819"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22054033-4e69-41b0-b321-a4d086d20574"}}}], "length": {"value": 0.0488534, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "96e610fa-0320-4fdb-a89f-9dc0244a5f46", "name": "l(r:p1rdt252lv-p1rlv440)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5fd6466-e740-4f06-a842-798195d62154"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a23f97bc-e7ef-4f64-9e64-314f4a4e17d8"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "3281c6b4-cd7b-405e-b82d-01608de0b3bf", "name": "padswitch(r:p1rdt5551-p1rdt5568)p1r_14627", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "514ad102-b590-4ad8-a258-2b6fa8dcbeb1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8aa126c-9b2b-4ae0-a4fc-36d4201762a0"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "6ba5defb-3101-4ef8-8d06-36719f7dad94"}}}}, {"uuid": "bf6157a4-7aa1-4ed3-b5bb-c658cc930d54", "name": "padswitch(r:p1rdt5551-p1rdt5568)p1r_14628", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64aba8d5-1dd3-4741-a8ba-26801e275ba8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c83b6ee-20fc-4ca0-a778-44735283afd5"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "b477d9d0-158a-46f2-92c2-f5870d9f433b", "name": "padswitch(r:p1rdt5548-p1rdt5577)p1r_14631", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25ee6008-ddbc-4e7b-8a57-ff38c16368a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c49b671-0b2b-43c9-bcb5-21c7b7e716ce"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "fa89ef5e-f965-457f-a553-4831f61b03c7"}}}}, {"uuid": "53cb1567-da04-45d8-9bf4-0dd5a812110d", "name": "padswitch(r:p1rdt5548-p1rdt5577)p1r_14632", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fead5749-3ba7-4ead-a604-e8adbd18f8c2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1c8b424-4509-4fd2-93e2-4fd54f6cf49a"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "3baa725a-9b39-45f8-86af-c6afda2cdf9f"}}}}, {"uuid": "f1d7385c-f334-4abd-acbc-268a6e1aa5fb", "name": "padswitch(r:p1rdt5557-p1rdt5563)p1r_14619", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cca8918c-30e6-4619-a5e0-8c0d3451f9c4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c94489ed-4399-4dab-bab6-02b79f240f63"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "2f835dde-37f4-47dd-ab96-214dd85d3c9e", "name": "padswitch(r:p1rdt5557-p1rdt5563)p1r_14620", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fbc31b75-f942-4bae-8712-f1666d8b7f26"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad24f98d-f022-4e62-b80b-426052810759"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "2419ddcd-627b-4faa-9878-65d4baf7d064"}}}}, {"uuid": "89b15386-98d4-4c15-bfd2-f82b5eea6b2a", "name": "padswitch(r:p1rdt5557-p1rdt5565)p1r_14621", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5e479d3-aae0-47b8-b707-bad1191df1e7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "efe7243f-340b-4114-be7c-f7494e78384f"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "ab2720f4-bdaa-4e93-a718-9d3398ce76a4"}}}}, {"uuid": "e2976123-591b-407f-8e3f-879e531049f6", "name": "padswitch(r:p1rdt5557-p1rdt5565)p1r_14622", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bfe92e2e-285d-4c58-8e0b-a462dd73fa41"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cca8918c-30e6-4619-a5e0-8c0d3451f9c4"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "bb21ddca-c238-4ca4-9574-9f21459c4f5a", "name": "padswitch(r:p1rdt5561-p1rdt5565)p1r_14623", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "756f6cd8-301b-4fac-b414-d72853616c6e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8bd0860f-2b3e-4c90-a571-cfc6aa649e5b"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "f58eeeef-b7c0-4252-b089-8de5183abc7c", "name": "padswitch(r:p1rdt5561-p1rdt5565)p1r_14624", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bebca5d7-2d4f-4655-a965-9faafd7a8125"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5e479d3-aae0-47b8-b707-bad1191df1e7"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "74d1d12a-803b-48eb-8e5b-0df008dc80b1", "name": "padswitch(r:p1rdt5551-p1rdt5561)p1r_14625", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f7fed4f-197e-4a79-97e5-df595377736b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27ab530f-a58e-4113-80f6-63f768910204"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "772c9103-cfcf-4ab9-ac69-f02423fe009f", "name": "padswitch(r:p1rdt5551-p1rdt5561)p1r_14626", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf97a458-469e-4609-bb33-97454e7c2b68"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "756f6cd8-301b-4fac-b414-d72853616c6e"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "278a53ba-f477-4f46-be13-b05dcff80778", "name": "padswitch(r:p1rdt5548-p1rdt5551)p1r_14629", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bf1b63d-fbce-42f8-9948-2e09bfa67409"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d447cf8-7b2b-45f1-8084-6fe4897e1853"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "c01372a2-4296-4877-a1f3-dd8c06d37f74"}}}}, {"uuid": "020e3a1d-353f-48a4-a297-a32861f78a5c", "name": "padswitch(r:p1rdt5548-p1rdt5551)p1r_14630", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ec70f12-a676-48cd-b626-34f8d7f6a5bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f7fed4f-197e-4a79-97e5-df595377736b"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "75397079-8541-4fed-9f2e-283746d35392", "name": "padswitch(r:p1rdt5548-p1rdt5566)p1r_14633", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fed9557-b170-4817-8bd8-efc3b9f7c982"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10f43169-4b4b-4dbe-8f09-af72d427d6c7"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4900e609-ebb1-44db-852b-602449095f15"}}}}, {"uuid": "9fbe0ee9-ae7d-4233-af14-ea12e83dc720", "name": "padswitch(r:p1rdt5548-p1rdt5566)p1r_14634", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23163dba-070c-435c-bb90-77be7ded002a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bf1b63d-fbce-42f8-9948-2e09bfa67409"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "d4fd35e4-7997-430a-854e-c1cdde29c7cc", "name": "padswitch(r:p1rdt5566-p1rdt5574)p1r_14635", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9906676-e9b9-4d51-b1c2-a6b6fe187faa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf619f04-1fa5-4be7-8a76-669b79436d3e"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "f3caa620-fb40-4165-abf4-46f624ae5a85", "name": "padswitch(r:p1rdt5566-p1rdt5574)p1r_14636", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c264e6de-a898-421d-a2fe-ce6548aa477e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fed9557-b170-4817-8bd8-efc3b9f7c982"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "8e708baa-3ad1-4899-8c29-fc507efdc551", "name": "fuse(r:p1rdt31-p1rdt38)p1r_16627", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7c543753-fa26-41df-b7a6-3664395c0d45"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "668d32be-c07a-4387-86a5-e9754af11e9c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "5ef87d33-a0f9-4b56-9457-0d7cb679088c", "name": "fuse(r:p1rdt210-p1rdt44)p1r_16628", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d9ee2ff-e2bc-4d76-b173-5ba5cc48c9b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1be5e34-ad5e-4c78-8067-8e0194c661a4"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "251fa307-5e1e-4ffa-a841-ff333862a949", "name": "fuse(r:p1rdt259-p1rdt44)p1r_16629", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d9ee2ff-e2bc-4d76-b173-5ba5cc48c9b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0b5743e-c3fd-49c7-879e-9be7d00c480f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "105be1c0-9f28-4814-ab44-267fbb4f0af7", "name": "fuse(r:p1rdt58-p1rdt69)p1r_16631", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9396562e-4f87-4e04-b248-502b851fe19e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7238345a-1fc7-4f3f-bc8b-88cf7582c75c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "c452d159-ea97-4544-ab4a-93d0e7ce8631", "name": "fuse(r:p1rdt37-p1rdt80)p1r_16632", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b03f8e29-a5b2-4bed-b68c-219276674b6a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a2b529c9-4695-42f3-a0e3-69bbb34ff285"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "da4bb223-04fc-4e5d-b2db-f16866497bb6", "name": "fuse(r:p1rdt74-p1rdt85)p1r_16633", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fc415bc-f457-4e9f-bbd4-783a71b67ad6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b82a9a2-b1d1-44eb-a451-946643ef613d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "58221277-9ee4-4071-8967-a1d0bdcbbf92", "name": "fuse(r:p1rdt150-p1rdt71)p1r_16651", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12451cbc-eb14-4814-b274-12eb2241c78a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eab6b8c5-ee7a-4779-b5eb-5205dbe5253c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "74603d74-9f0d-4842-b655-cfdee489dad0", "name": "fuse(r:p1rdt251-p1rdt254)p1r_16679", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b801037a-e1bb-4c5c-8d18-ed285c8c1d3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9c899bc-796a-4e92-88db-6aa11f8777cb"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "25c5e70e-dd57-4030-b431-72effcf942e6", "name": "fuse(r:p1rdt252-p1rdt385)p1r_16680", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69b2ee46-ab5f-48c8-a26b-170ed2b57fcb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22179eaa-fd19-4619-8b31-52bcb36ec683"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770"}}}}, {"uuid": "af70abad-e2d2-466e-ac06-19c43f7ce09a", "name": "fuse(r:p1rdt261-p1rdt277)p1r_16684", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "add5e39f-f02e-4a61-a156-d5721cec25d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bbe3ac37-aca0-47fd-ac5d-be390cad10ab"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "5cb48d44-c6a0-4b2a-ae95-38168b6ed9e6", "name": "fuse(r:p1rdt279-p1rdt89)p1r_16685", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "153bb615-5ee5-4eec-bcf7-94ea0098aeb6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "232adbbb-2715-44be-8db5-ee062ebf4e46"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "ae0efabc-30d4-4b0b-87f1-14de9ef567fc", "name": "fuse(r:p1rdt335-p1rdt376)p1r_16692", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b07c4a6-39a7-4521-bce7-3f1ca0ff4a66"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0de112ae-d04a-4673-98af-0699e4890429"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "804bf703-8117-4553-b55c-90b0e0138f28", "name": "fuse(r:p1rdt415-p1rdt419)p1r_16706", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81cfd2a2-295c-4b73-abba-05ffee810523"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19116f3c-29ae-4819-ba72-dd0f8afa5078"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "cc0d8f4f-cb74-41bf-915f-657a26c4dce0", "name": "fuse(r:p1rdt456-p1rdt465)p1r_16710", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a94f7afe-e8b0-4b24-8196-6b05e98c3830"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b092ee09-4c5e-46b5-8ec2-51f99254c220"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "9d67edf0-3af2-46a6-b5a7-af017e3a23be", "name": "fuse(r:p1rdt458-p1rdt468)p1r_16711", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a180b972-cf0e-4a2e-9bcf-a0ad90bb3d83"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04fc215c-7f3e-45e1-a49c-727b0fcdae93"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770"}}}}, {"uuid": "e812226f-f357-4c18-96e8-9949554baf21", "name": "fuse(r:p1rdt468-p1rdt474)p1r_16712", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a180b972-cf0e-4a2e-9bcf-a0ad90bb3d83"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5814195b-dd60-4a1e-9af6-b9b84fa4c0c7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "9860b763-07dc-4e8d-8870-1afd3a7f37e2", "name": "fuse(r:p1rdt466-p1rdt478)p1r_16713", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eba354c-f4bf-4c49-a8ad-998ab9489e5a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64ba6716-89f9-49a4-9793-ba80ae41bcd0"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "da8c1709-80de-4678-8309-269d2f230e38", "name": "fuse(r:p1rdt482-p1rdt485)p1r_16714", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "445f61a4-8045-4558-a3c1-bb44336737ec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4064b6c-40b4-418b-95ab-4f9bb0363b14"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770"}}}}, {"uuid": "c04ff227-206a-442c-a266-475342372f3b", "name": "fuse(r:p1rdt483-p1rdt485)p1r_16715", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "445f61a4-8045-4558-a3c1-bb44336737ec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d899b807-b194-4f65-bad5-a39e8bc61906"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "2b29065b-ab29-4a29-992e-6fa020baefb0", "name": "fuse(r:p1rdt5548-p1rdt5577)p1r_17662", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bf1b63d-fbce-42f8-9948-2e09bfa67409"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25ee6008-ddbc-4e7b-8a57-ff38c16368a2"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "73f75b89-55b4-4a16-9fa1-8771daf3d5be"}}}}, {"uuid": "ac5b78b4-1db7-4049-8ac8-190123ae26d7", "name": "fuse(r:p1rdt5551-p1rdt5568)p1r_17664", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f7fed4f-197e-4a79-97e5-df595377736b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "514ad102-b590-4ad8-a258-2b6fa8dcbeb1"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "861d64ae-aba6-4135-a3ca-f177438722a2"}}}}, {"uuid": "6de2926c-cdd7-4dbe-954c-e5e73d440add", "name": "fuse(r:p1rdt5560-p1rdt9055)p1r_17668", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68117bef-16c5-40c9-9356-76ef5c056650"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30adfcd5-405b-47ea-be54-55c5a47c835f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "b77c5f87-769c-4ad7-b6b5-9fbe48d98a9e", "name": "fuse(r:p1rdt6488-p1rdt7300)p1r_17851", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63b2f1e6-5e15-4433-85ee-ff7bb7218b96"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47f8ed28-4bff-47d9-8ffe-4509e9c5b7fc"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "3228c925-05c0-4c64-b9fc-c95e6716280b", "name": "fuse(r:p1rdt7757-p1rdt7795)p1r_18078", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "081feb5c-d5d5-405e-85d4-f1dd0916fc3d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0cd22d3e-1e2a-4a99-9967-b9df95837915"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "5bbe221f-b4a5-48b0-807d-e4b8038385f1", "name": "fuse(r:p1rdt8111-p1rdt8138)p1r_18142", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17b633c6-214d-4428-bded-df737f50ffb6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9929e0d4-3e33-4f5f-b718-6a629cc52242"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "1f205dc8-03e2-4638-9e38-39bda752ee14", "name": "fuse(r:p1rdt5098-p1rdt8169)p1r_18150", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6bdb2cf-9373-4d56-a5f9-cb8fa9c67e55"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb3d775d-8d92-498b-989c-387278ec8e9e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "7a9f88b5-9266-4dc3-94d4-4b1fd3397487", "name": "fuse(r:p1rdt6266-p1rdt8174)p1r_18152", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b0f9433-e0a3-458a-8687-c9cf38d0bbb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d07105ef-1ba3-4775-aeb4-650b5ea8736e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770"}}}}, {"uuid": "d30f8def-15f6-47be-ab3f-8814ccb37121", "name": "fuse(r:p1rdt8180-p1rdt8201)p1r_18154", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c93a476-4ad5-41cd-a07b-e2ccc9ef2c3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63928702-c44a-4e83-9cca-7ce77bdbd2b3"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "6b0a6718-181b-4c20-9dc3-45257942ad04", "name": "goab_disswitch(r:p1rdt335-p1rdt419)p1r_20734", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81cfd2a2-295c-4b73-abba-05ffee810523"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2efeaf5-2055-4718-a064-7c5e00b7d87d"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "2419ddcd-627b-4faa-9878-65d4baf7d064"}}}}, {"uuid": "a8dbe250-f335-4a33-8967-d9144ec88082", "name": "goab_disswitch(r:p1rdt276-p1rdt279)p1r_20887", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "186ffdfe-2346-4218-bd6b-b813ea6b3b62"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7140d97e-416e-47ec-9f86-46ad6f9abece"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "466a17b2-2a29-4496-8652-610b208f7f1b", "name": "disswitch(r:p1rdt181-p1rdt297)p1r_20911", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d32493ec-06be-48ef-959e-779c79c507a3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2fddf29e-6eef-4c60-ad8b-4580440973b3"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "7351fbec-02bf-4cbf-aea9-09a23aa2a9b8", "name": "goab_disswitch(r:p1rdt237-p1rdt276)p1r_20993", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8c8b8f8-7a41-4d16-b509-2d7c7af9509d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3ca9bee-26b0-4ef4-8555-6494ffdd6a17"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "2a5a5f0e-3473-4d3f-ac60-0c576781cacc", "name": "disswitch(r:p1rdt16790-p1rdt487)p1r_21007", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfb0d992-ab18-4f73-933e-a01ce73ef3b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d53ff9fd-2b16-4026-88fa-2c112d4949c5"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "e7ce538c-39a2-4585-8cd8-85cefb5001b7", "name": "disswitch(r:p1rdt16604-p1rdt257)p1r_21113", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fb307f7-3690-4931-999a-4daab4d8c9e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ef71bd7-4c82-4296-a6ac-64516ffe96c5"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "2d897f3c-bcb4-45c3-8f45-79a7882361d3", "name": "disswitch(r:p1rdt270-p1rdt298)p1r_21212", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a468f13-c61f-4c01-aa27-c75fb02030e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2c76250-d7ea-4da4-8008-dac1a579e974"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "05155e19-68bb-4b06-a90e-2af3c0f63384", "name": "recloser_disswitch(r:p1rdt8174-p1rdt8180)p1r_21285", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b0f9433-e0a3-458a-8687-c9cf38d0bbb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "498a07ee-e12b-459a-a01f-f663a4a8428a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "b8590a64-3624-43d1-8279-40a7928d98a9"}}}}, {"uuid": "4d2272d5-4fc9-48e9-84db-9b8f3f9f327a", "name": "disswitch(r:p1rdt383-p1rdt7300)p1r_21354", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05f14a3e-053e-4b65-b962-da7804b9e2c1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9240d01-bf5d-41ed-8c53-c1f04af1a236"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "c57b3c83-e7ed-4283-84e7-230a16052433", "name": "l(r:p1rdt383-p1rdt7300)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ac1506-77e9-4b90-ad3d-18be099063a9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16ace27f-f5fa-4fd1-840e-8cae55dbe1b2"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "40a26197-da2a-4e22-a50a-3922efd7762c"}}}}, {"uuid": "dfe3055b-071a-4b16-a1f5-8817c9563e7c", "name": "l(r:p1rdt383-p1rdt7300)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16ace27f-f5fa-4fd1-840e-8cae55dbe1b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d49257c8-f8eb-4024-9c02-461d18cdd3d5"}}}], "length": {"value": 2.9030580000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4bd7147d-d66a-4be7-afc9-1ac8815e7212", "name": "l(r:p1rdt181-p1rdt66)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24681ab1-3904-4509-85e6-d9bb1dba4c8e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6b5c947-b0c5-4e20-bd74-bf847bdacd30"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "40a26197-da2a-4e22-a50a-3922efd7762c"}}}}, {"uuid": "239c598c-522f-4509-8755-3e56148c7ce9", "name": "l(r:p1rdt181-p1rdt66)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6b5c947-b0c5-4e20-bd74-bf847bdacd30"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99615f32-0614-4c23-a1e1-b3e8e5688cce"}}}], "length": {"value": 1.8166859999999998, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c0340108-7ee4-45aa-91e0-afcce5d859a4", "name": "l(r:p1rdt181-p1rdt297)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d87f56c0-0a3f-4a94-8f60-1ece461290d0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "71abd5f1-ca61-4754-a2ef-7b5d4e635f99"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "40a26197-da2a-4e22-a50a-3922efd7762c"}}}}, {"uuid": "ef009cf0-e83d-4133-b85e-647ec7c82b7f", "name": "l(r:p1rdt181-p1rdt297)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "71abd5f1-ca61-4754-a2ef-7b5d4e635f99"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79d0fee6-369b-4f95-a2d2-cd05232652e3"}}}], "length": {"value": 4.570002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d448bbc0-7a67-4bb2-94aa-7d605ebab0df", "name": "l(r:p1rdt270-p1rdt298)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac7c613f-190c-493e-8e89-3ef48e8efdb9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0fad7ee-b65c-460c-94ca-fe9546a5b140"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "40a26197-da2a-4e22-a50a-3922efd7762c"}}}}, {"uuid": "c9722f40-a6c0-4a05-a737-bd2ff278c33d", "name": "l(r:p1rdt270-p1rdt298)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0fad7ee-b65c-460c-94ca-fe9546a5b140"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7eca59ac-01f1-40d7-a0ec-51f355285e01"}}}], "length": {"value": 2.6162099999999997, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3e4e6114-3df1-4523-b480-028a3f01d2e4", "name": "l(r:p1rdt16604-p1rdt257)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "282d8a89-8b14-476b-9e55-b310d8b9396d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8064f1d-11b7-4913-8344-175c1388be3e"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "40a26197-da2a-4e22-a50a-3922efd7762c"}}}}, {"uuid": "642f1479-fef3-4ab0-869d-276f7aaeca18", "name": "l(r:p1rdt16604-p1rdt257)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8064f1d-11b7-4913-8344-175c1388be3e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98a946e8-3c8a-49ec-be8a-5610c7fc596c"}}}], "length": {"value": 2.362599, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a7288c5c-c39d-4983-bd6a-e028ec000d5f", "name": "l(r:p1rdt7711-p1rhs7_1247)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1548dd91-bc3d-4a2c-903f-48e11159c558"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2131350-dc34-4d8d-8c9f-c29e25bc654c"}}}], "length": {"value": 2.34083, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "dfffd734-a5e2-42da-a25d-4360affa98b0", "name": "l(r:p1rdt7711lv-p1rlv16411)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64b60527-0853-4973-8d7a-78ba5e377799"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ed6276c-a57b-40be-a1f1-34aaaba0ac28"}}}], "length": {"value": 0.0104732, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "4eb8fe85-248b-4062-b84b-bd291bf09b51", "name": "l(r:p1rdt7711lv-p1rlv20414)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64b60527-0853-4973-8d7a-78ba5e377799"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0a92e79-0ca2-4a10-9050-9e8d7442b019"}}}], "length": {"value": 0.0104732, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "9e9dcf4a-3b83-4e15-a8d0-6f5351cdc13c", "name": "l(r:p1rdt8473lv-p1rlv18169)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "439728c5-fee5-4dfa-9894-261ba6c40e95"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c1eac45-623a-4f0a-874d-a4b56a8e2ea7"}}}], "length": {"value": 0.0202596, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "8285453f-abc7-420b-93ac-60cb9aaef09e", "name": "l(r:p1rdt8473lv-p1rlv18194)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "439728c5-fee5-4dfa-9894-261ba6c40e95"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "949f4cce-f321-4bf0-830b-489edc9964c7"}}}], "length": {"value": 0.0202596, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "d9d639df-5b76-47fe-9b75-d4e7ec515ae1", "name": "l(r:p1rdt6028lv-p1rlv12518)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35f6f747-811d-4fe2-a9c7-991248572c74"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72f659b6-d302-4887-a2f6-1a477ad3324c"}}}], "length": {"value": 0.0196521, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "9475313a-299b-446b-91ed-94cdb2d345d5", "name": "l(r:p1rdt6028lv-p1rlv12528)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35f6f747-811d-4fe2-a9c7-991248572c74"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9660b80-0fce-4be4-b541-743d5811133c"}}}], "length": {"value": 0.0563852, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "ffe84a3b-76b8-4dec-9c29-0084691588fe", "name": "l(r:p1rdt6028lv-p1rlv12534)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35f6f747-811d-4fe2-a9c7-991248572c74"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8796d817-aad6-4d22-b3d4-baf8a686c9df"}}}], "length": {"value": 0.00754144, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "4a309f30-e352-4599-9dee-ffca476a4e9e", "name": "l(r:p1rdt6028lv-p1rlv12536)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35f6f747-811d-4fe2-a9c7-991248572c74"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e89452f3-ce44-46d3-a259-f66044e01c2c"}}}], "length": {"value": 0.0368264, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "7399e1c5-5e83-4fa9-a9b6-9d3a1a693f55", "name": "l(r:p1rdt9478lv-p1rlv20501)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddf38626-1223-429f-a903-98f1c975020b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cebe1b53-cca6-4bd4-a9f0-616ffb9750b3"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "f3e4b646-2702-4787-930b-a42a5c45d53f", "name": "l(r:p1rdt6232lv-p1rlv12985)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e2630e1-a215-4740-9327-fa004e89863d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df3aae83-f4b0-4db2-9301-dff1664ac23e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "8e5baa4c-dd50-4330-b9cb-45f46ac26d1c", "name": "l(r:p1rdt6232-p1rdt9478)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c49b6e87-5834-4e7e-a64c-b4ec0f7d4995"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b59ad93a-cca2-4a77-8515-a645ddd2a320"}}}], "length": {"value": 0.08088850000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d287939e-187e-44ce-adc8-c5deb1efe035", "name": "l(r:p1rdt6028-p1rdt9478)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e39cb1db-d6a6-4b6c-bc73-920e0c34c292"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f77960bf-f017-400c-b505-16e7c2e90fe7"}}}], "length": {"value": 0.29557, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "38175911-904e-413e-b9f3-ba12b0d54714", "name": "l(r:p1rdt6028-p1rdt8473)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3a83211-0829-4e2c-b618-3f1fcaba3e87"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e39cb1db-d6a6-4b6c-bc73-920e0c34c292"}}}], "length": {"value": 0.233087, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "24ba44ff-6a1e-424c-802a-5e685da39576", "name": "l(r:p1rdt7711-p1rdt8473)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2131350-dc34-4d8d-8c9f-c29e25bc654c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3a83211-0829-4e2c-b618-3f1fcaba3e87"}}}], "length": {"value": 0.502313, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "c94a5bb4-b7c5-4f79-9cf8-1375d4c8b6cb", "name": "l(r:p1rdt8493lv-p1rlv18201)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c330731a-fd2c-40c7-8fce-94f7e17cf6d9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ead37cb8-af1e-4a46-9466-6ff298b7f8b7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "248b171b-5e13-4070-b36a-12d088475c3c", "name": "l(r:p1rdt7711-p1rdt8493)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2131350-dc34-4d8d-8c9f-c29e25bc654c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfb41891-7063-44b8-9286-1fe763e49924"}}}], "length": {"value": 0.719466, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "5cd18c4b-7e66-4567-99aa-adbf0e339973", "name": "l(r:p1rdt6028-p1rdt9478)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f77960bf-f017-400c-b505-16e7c2e90fe7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "409a29cf-ddd5-4031-92ca-db6cd2410704"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "937849ae-e1ac-40fe-b786-984a89a281f3", "name": "l(r:p1rdt6028-p1rdt9478)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "409a29cf-ddd5-4031-92ca-db6cd2410704"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c49b6e87-5834-4e7e-a64c-b4ec0f7d4995"}}}], "length": {"value": 2.66913, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "87fc45c2-660b-4f99-b658-eb377ae27502", "name": "l(r:p1rdt93lv-p1rlv183)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0921e58d-1ada-4556-8b01-8f22d3bf4ee2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3df778b4-e60b-4e17-b24b-67742d090f42"}}}], "length": {"value": 0.062918, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0c7ce66f-32b1-4f29-8c1b-ff8cb7cbe189", "name": "l(r:p1rdt93lv-p1rlv204)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0921e58d-1ada-4556-8b01-8f22d3bf4ee2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d663fcdc-6c67-4bc9-99ed-12439f75804f"}}}], "length": {"value": 0.0275441, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c67015ab-e194-4fac-82b0-87878c41d658", "name": "l(r:p1rdm198-p1rlv206)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2be21180-bfa8-4cd1-a3c5-68602896d657"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90aa0d14-285a-4468-bbde-8d76f65b1780"}}}], "length": {"value": 0.047457, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "04bb6407-6835-4d3c-8629-76af3bf1c2ae", "name": "l(r:p1rdm198-p1rdt93lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0921e58d-1ada-4556-8b01-8f22d3bf4ee2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2be21180-bfa8-4cd1-a3c5-68602896d657"}}}], "length": {"value": 0.0116535, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8364cd7f-2820-4bcf-bb37-67dadafb4bb2", "name": "l(r:p1rdm199-p1rlv207)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a70fd02-3816-451f-a509-2ad767068eb4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6627102c-4524-4e69-bb4d-5b93226df412"}}}], "length": {"value": 0.0665106, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a2920457-6a3e-4fb5-95d3-b5dfbe0a7490", "name": "l(r:p1rdm196-p1rlv184)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6065e92f-dd89-4aeb-94af-173d81a49df1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42ca8327-5dcc-415a-820c-ef6ec038b3d8"}}}], "length": {"value": 0.0719696, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "382af86a-c688-4778-b6b8-2005858ec39b", "name": "l(r:p1rdm196-p1rdm199)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a70fd02-3816-451f-a509-2ad767068eb4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6065e92f-dd89-4aeb-94af-173d81a49df1"}}}], "length": {"value": 0.0157359, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "796dcb0c-914a-4476-8a88-6a5c6023faca", "name": "l(r:p1rdm199-p1rdt93lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0921e58d-1ada-4556-8b01-8f22d3bf4ee2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a70fd02-3816-451f-a509-2ad767068eb4"}}}], "length": {"value": 0.00889089, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "2d347746-0969-4a8a-b986-c40ef4f4c015"}}}}, {"uuid": "3a950c68-44a5-458a-ae67-40de974d8047", "name": "l(r:p1rdt99lv-p1rlv190)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef6be92d-5d1b-40e2-a2c2-9d0c1f0bf596"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33b6400e-c84e-43cf-b254-99f946e5a308"}}}], "length": {"value": 0.040055, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4ab7dd7f-8f59-4338-807a-6a59fdb9d2c6", "name": "l(r:p1rdt99lv-p1rlv202)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef6be92d-5d1b-40e2-a2c2-9d0c1f0bf596"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "de2366e4-30da-429a-82b9-c0ef27eeab47"}}}], "length": {"value": 0.040055, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c79aa124-41f0-475e-b27b-c7974a25b335", "name": "l(r:p1rdt101lv-p1rlv193)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1277a701-9fbd-4853-a809-962475e016c4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84223c1b-69e4-4ebc-8274-8706bb412780"}}}], "length": {"value": 0.060663, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "5ef15021-e9f7-4934-ad47-fa982ef83d7f", "name": "l(r:p1rdt108lv-p1rlv212)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3aa8d6f2-8d84-42d6-8e7b-89e3b1efa03c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a982feac-5730-4fe0-a1b8-25c06b36e3b0"}}}], "length": {"value": 0.0158014, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9ba90c4e-cda5-4a96-8214-9766f675c80a", "name": "l(r:p1rdt6121lv-p1rlv12687)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "448cc5e0-391f-4a6b-8199-25cef4593edf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "163c3824-6847-4b94-9e81-08f15f4667a1"}}}], "length": {"value": 0.0852199, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b466ad0c-36a2-4215-b99e-1e2e9147cca4", "name": "l(r:p1rdt6123lv-p1rlv12713)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e81ba94-5857-42e4-aeee-58542cef0fb6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff16aad0-98c1-4563-a844-e0ce909c1a79"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "6db4a71c-d59e-49fb-b9ee-3aebd949e6ab", "name": "l(r:p1rdt8017lv-p1rlv17006)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8428de0e-4b06-4f19-bffb-5fed32f96f67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b53edd15-5a3e-4b7a-97c4-046582bb4801"}}}], "length": {"value": 0.0396626, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6f7024dc-43c4-4070-b610-d88c786d2e4b", "name": "l(r:p1rdt8043lv-p1rlv17103)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a367e687-b29a-44b4-a943-7b94762e549e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ff9eb4c-2523-48e0-8490-619d26b9cca4"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b797d3a2-ee2f-4f54-b06e-9fa0e6dbb21e", "name": "l(r:p1rdt8065lv-p1rlv17155)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8bb025c5-31eb-4771-b433-e1dcad03b3ed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3c6c52e-cf93-467a-a303-94b96b33a3da"}}}], "length": {"value": 0.00641649, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6f467e58-32b6-4e07-9a32-2fcae57445d9", "name": "l(r:p1rdm17752-p1rlv17164)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62e77e46-bf33-474f-907b-81d36aae8975"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "041caa30-2985-44ca-8013-e11a9bda7dff"}}}], "length": {"value": 0.0585553, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "aa9f431f-8d45-4d2f-b3ef-6ed973e7fdfe", "name": "l(r:p1rdm17752-p1rdt8068lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd01eed6-0e70-42e7-ac29-4bfd2f70366a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62e77e46-bf33-474f-907b-81d36aae8975"}}}], "length": {"value": 0.00975828, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "46cadd28-41d2-4b33-b229-53938b6526d2", "name": "l(r:p1rdm17753-p1rlv17199)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "46b5c5bc-6738-4520-b98c-32bd43f4c91c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5768eaca-abe3-4347-af78-02b50ec6f2a9"}}}], "length": {"value": 0.07246250000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "815be72a-4590-47bf-b23a-93bee76e3ffc", "name": "l(r:p1rdm17753-p1rdt8068lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd01eed6-0e70-42e7-ac29-4bfd2f70366a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "46b5c5bc-6738-4520-b98c-32bd43f4c91c"}}}], "length": {"value": 0.00869985, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "07d3ecbb-c8d8-4498-b7de-9dede233fa9a", "name": "l(r:p1rdt8070lv-p1rlv17167)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0bcd460-ccf2-42ee-83c6-bada397ab4d6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b4e44ab-e644-4e48-b1b2-82dc15d38d17"}}}], "length": {"value": 0.0455049, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e1c383ad-81e0-4ef4-8d77-433f8c2369fc", "name": "l(r:p1rdt8190lv-p1rlv17376)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f21f4e99-8877-4bb0-9956-9240bc6db3d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c9970ae-e914-407d-8222-12c08638a854"}}}], "length": {"value": 0.0538062, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "5c4315d9-3bd5-4e8d-8f59-4e452cc39791", "name": "l(r:p1rdt8204lv-p1rlv17402)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d12bf6fb-8dac-4729-bcda-1ee61c63f6e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc7fa312-1baf-4f23-925f-a281071183a6"}}}], "length": {"value": 0.020109400000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "930a8c5d-1c84-449e-aeb0-b249e1fc8fbe", "name": "l(r:p1rdt8208lv-p1rlv17413)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ecf11723-eb6d-423c-ac0c-85fa2d1ba846"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f147f7e5-33e8-430b-9822-715e772debb3"}}}], "length": {"value": 0.058289, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "49a21a95-e38f-4a69-be2a-b889705a3a47", "name": "l(r:p1rdt8578lv-p1rlv18362)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1a593e3-4735-47d2-b893-dd2d07c3c47c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a28b095-45f5-43ec-983b-c1de596d4cb5"}}}], "length": {"value": 0.0205693, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "dc98da20-4587-480f-8cb1-3a411d9e0658", "name": "l(r:p1rdt8578lv-p1rlv18364)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1a593e3-4735-47d2-b893-dd2d07c3c47c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d1c3d0a-9def-4516-8429-386f1d70f506"}}}], "length": {"value": 0.0370574, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f8487d44-54da-4eec-870f-b9de934b0640", "name": "l(r:p1rdt8578lv-p1rlv18367)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1a593e3-4735-47d2-b893-dd2d07c3c47c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "408c825d-17ac-4aea-9fc7-fff420657fc7"}}}], "length": {"value": 0.018828, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cce59d54-5697-4708-a924-410992705356", "name": "l(r:p1rdt8583lv-p1rlv18370)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "134bac3d-5b7e-48d7-950e-01e5b7d43852"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905e171c-13d7-4f8d-b88a-7501b2327d81"}}}], "length": {"value": 0.0934621, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "72285fbb-7891-4916-bd04-d67ce9189e58", "name": "l(r:p1rdt8584lv-p1rlv18371)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8ba1042-fcfd-47a8-aa0f-8b13618d3212"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58792e8c-3ad9-45bb-ac47-01983cca2a2b"}}}], "length": {"value": 0.0568796, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0ed44728-cace-4d39-8182-28659b1113a8", "name": "l(r:p1rdt10491lv-p1rlv22745)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8f14e6e-ee96-4ae9-86ba-4a07cf103b65"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a86348e4-7573-4903-b223-90155579923e"}}}], "length": {"value": 0.00860717, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "69f39247-71ec-4488-a1b5-9cd9caff8cb6", "name": "l(r:p1rdm23269-p1rlv22758)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee8b6bab-9edd-4250-b57b-3a76b432fb54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db05b7f0-d2a8-4876-876e-ef0e9b469580"}}}], "length": {"value": 0.0077383, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "545f2993-60ea-4122-8ac8-124799e17c31", "name": "l(r:p1rdm23269-p1rdt10491lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8f14e6e-ee96-4ae9-86ba-4a07cf103b65"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee8b6bab-9edd-4250-b57b-3a76b432fb54"}}}], "length": {"value": 0.017970700000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a19ed19d-f5f9-42c8-b5d1-520605196747", "name": "l(r:p1rdt8065-p1rdt8070)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473520c7-0098-4bc2-a46f-07efd6c3759c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "862f3566-9443-4b82-8f05-c994581e131a"}}}], "length": {"value": 0.11506000000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f82ea167-4bb5-4acb-8736-ba3098b01929", "name": "l(r:p1rdt8068-p1rdt8070)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473520c7-0098-4bc2-a46f-07efd6c3759c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f5fbb8b-0c32-4aa7-acaf-7ea2b5e56505"}}}], "length": {"value": 0.0454225, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "2cfe2726-ca82-4184-af38-1db485d3622d", "name": "l(r:p1rdt8043-p1rdt8070)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "691c1909-3b71-4e07-abf0-95aaabfa23bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbafbe81-1649-4bae-b9af-c4b1757392f0"}}}], "length": {"value": 1.20903, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c939ca25-23bc-45e6-afb1-34c98b300b8d", "name": "l(r:p1rdt8043-p1rdt8070)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbafbe81-1649-4bae-b9af-c4b1757392f0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473520c7-0098-4bc2-a46f-07efd6c3759c"}}}], "length": {"value": 0.714168, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1a6283f9-eca9-4da3-9aec-868e430d702b", "name": "l(r:p1rdt10491-p1rdt8043)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "691c1909-3b71-4e07-abf0-95aaabfa23bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ca19324f-0855-4633-be68-b16c872e196d"}}}], "length": {"value": 0.143178, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f42fe8fc-80ec-4c50-a106-91fa534f3edc", "name": "l(r:p1rdt10491-p1rdt8043)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ca19324f-0855-4633-be68-b16c872e196d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4737e613-8cf5-45d7-a3f5-71af051ece4c"}}}], "length": {"value": 1.81692, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d5dee6d5-a427-4319-b9b9-44bc16841f5f", "name": "l(r:p1rdt8017-p1rdt8043)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6378abd-969e-4ec8-93eb-2cc39cdb18eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "feda8d99-6fae-4c6e-bf52-f87894687da5"}}}], "length": {"value": 0.18707900000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ccb7a0ac-a308-4217-afd4-043b2b325c6b", "name": "l(r:p1rdt8017-p1rdt8043)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "feda8d99-6fae-4c6e-bf52-f87894687da5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "691c1909-3b71-4e07-abf0-95aaabfa23bb"}}}], "length": {"value": 0.534353, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "db26ea21-d0ad-492d-88d3-62e4b8b52675", "name": "l(r:p1rdt101-p1rdt8017)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a09cdbca-4e7b-4d9a-b479-515074964171"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1aeba4b-536e-4067-a7a5-627470ae0711"}}}], "length": {"value": 0.331129, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b5b98590-9dc7-4cd0-a4d2-066a47550a6e", "name": "l(r:p1rdt101-p1rdt8017)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1aeba4b-536e-4067-a7a5-627470ae0711"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c1a4365-a594-48be-b138-aa6935c34481"}}}], "length": {"value": 2.00417, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e7f6e4db-47b4-40d6-b0c7-8836d796842d", "name": "l(r:p1rdt101-p1rdt8017)_s2", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c1a4365-a594-48be-b138-aa6935c34481"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6378abd-969e-4ec8-93eb-2cc39cdb18eb"}}}], "length": {"value": 0.0990287, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "358ea440-8af5-49f3-a7e5-bf3ece06fe47", "name": "l(r:p1rdt101-p1rdt108)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e61ce952-a643-45aa-a466-8aa15ecceb48"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d8e5d83-cd9c-4527-9eef-6219c98dfe93"}}}], "length": {"value": 0.0862881, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e86bf583-73fe-41bb-bdae-274719a15774", "name": "l(r:p1rdt108-p1rdt93)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4f100ee-0152-4e27-bf0e-2c7dea1537ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e61ce952-a643-45aa-a466-8aa15ecceb48"}}}], "length": {"value": 0.0403624, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "73cf1758-bfb1-404d-80ef-ae8deceb880c", "name": "l(r:p1rdt8204-p1rdt8208)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e2b4d77-2388-4897-86fe-06409fa9d222"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa2342e6-2d40-424a-830c-a84af4632b6e"}}}], "length": {"value": 0.29712, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bc1ca79c-0481-4721-87d4-46e512a8cdcd", "name": "l(r:p1rdt8190-p1rdt8208)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a761aef-a766-40e2-b8d7-e5a918cece18"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e2b4d77-2388-4897-86fe-06409fa9d222"}}}], "length": {"value": 0.056324900000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e3ede097-3f6e-463a-8da9-8632b7c482b3", "name": "l(r:p1rdt8190-p1rdt99)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b860d5c-43e4-429e-b945-378020e3f926"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6be75535-8c32-47ea-bad5-986daaed0921"}}}], "length": {"value": 1.66165, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "700118f2-7a55-4195-9574-c5978603f45e", "name": "l(r:p1rdt8190-p1rdt99)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6be75535-8c32-47ea-bad5-986daaed0921"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a761aef-a766-40e2-b8d7-e5a918cece18"}}}], "length": {"value": 0.18014, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1b462af5-d08e-4ef0-a01e-73536834674c", "name": "l(r:p1rdt6121-p1rdt6123)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddf8f344-dcca-418d-850e-745f18d29660"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17f807ba-6ad6-4fd9-9dd0-2c0bacea5b24"}}}], "length": {"value": 0.192685, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d1b3aa3f-5f80-4d51-a2cd-0171c797aabb", "name": "l(r:p1rdt8583-p1rdt8584)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0747505-3381-4df0-a86e-3859acac8496"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b601580-3091-4d8c-9718-1367c7ed385f"}}}], "length": {"value": 0.11744700000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5a01c8c2-afff-4ba5-957f-a2692170814e", "name": "l(r:p1rdt93-p1rdt99)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "092a9d51-a39c-4c05-905e-93fb1ae96ba2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3d15ce6-878d-4dd5-bb33-5a0f6c11dded"}}}], "length": {"value": 0.141059, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "9a0a937c-8779-4945-b7a2-5c75476497cb", "name": "l(r:p1rdt93-p1rdt99)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3d15ce6-878d-4dd5-bb33-5a0f6c11dded"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "900d49ce-4834-4f99-8d74-a5e9d2f63ea0"}}}], "length": {"value": 0.0271696, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "bcaefac9-1c3b-4558-a4c8-277deff0ddcc", "name": "l(r:p1rdt6121-p1rdt99)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2390c014-d418-4d63-8438-529a036487db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49c9e6df-3490-4df1-88a0-8a83ca6cdd1e"}}}], "length": {"value": 0.978472, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "0aff09d1-b70c-477f-bd3b-0d2d1a8a6a03", "name": "l(r:p1rdt6121-p1rdt99)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49c9e6df-3490-4df1-88a0-8a83ca6cdd1e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "092a9d51-a39c-4c05-905e-93fb1ae96ba2"}}}], "length": {"value": 0.2822120000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "ec452fcc-6021-44bc-9ae1-4cb5035bb351", "name": "l(r:p1rdt6121-p1rdt8578)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb866499-9e9c-4394-bd76-d4320ba4934b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "af229e5c-a70f-4354-bddc-4a2698802741"}}}], "length": {"value": 0.28336300000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "439d6b78-6099-4abb-8944-85f4bdab8a16", "name": "l(r:p1rdt6121-p1rdt8578)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "af229e5c-a70f-4354-bddc-4a2698802741"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2390c014-d418-4d63-8438-529a036487db"}}}], "length": {"value": 3.58548, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "1950c059-99fb-4401-9f5c-76a93b596633", "name": "l(r:p1rdt8578-p1rdt8583)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dbb79e10-21ba-4f04-b8a3-0cf711d26d40"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "975237e9-bd83-4a30-83ab-221eb7f85c65"}}}], "length": {"value": 0.101019, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "562e52da-0402-4236-9daa-19322b4c4c58", "name": "l(r:p1rdt8578-p1rdt8583)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "975237e9-bd83-4a30-83ab-221eb7f85c65"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb866499-9e9c-4394-bd76-d4320ba4934b"}}}], "length": {"value": 0.293916, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "2e7af12b-e8d8-4dd6-b6a9-cd3b777924ce", "name": "l(r:p1rdt8583-p1rhs7_1247)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec7726f8-0afb-4c35-8a1b-0691a8fb400d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dbb79e10-21ba-4f04-b8a3-0cf711d26d40"}}}], "length": {"value": 1.53928, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "7393d5be-c8ab-4241-b345-50487d39c030", "name": "fuse(r:p1rdt108-p1rdt93)p1r_16636", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "900d49ce-4834-4f99-8d74-a5e9d2f63ea0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4f100ee-0152-4e27-bf0e-2c7dea1537ad"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "3b608405-4c97-4531-bc3d-fd9d98d5eef0", "name": "fuse(r:p1rdt8190-p1rdt99)p1r_16637", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "092a9d51-a39c-4c05-905e-93fb1ae96ba2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b860d5c-43e4-429e-b945-378020e3f926"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "872c97b3-853e-44ec-9dc5-76b3b0c97047", "name": "fuse(r:p1rdt6121-p1rdt6123)p1r_17782", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2390c014-d418-4d63-8438-529a036487db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddf8f344-dcca-418d-850e-745f18d29660"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "eebb5679-e562-4c44-912d-f2a3cf81f9a7", "name": "fuse(r:p1rdt8583-p1rdt8584)p1r_18243", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dbb79e10-21ba-4f04-b8a3-0cf711d26d40"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0747505-3381-4df0-a86e-3859acac8496"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "96f5f10a-4b99-43c0-ace7-9392756edbb1", "name": "disswitch(r:p1rdt101-p1rdt8017)p1r_21072", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d8e5d83-cd9c-4527-9eef-6219c98dfe93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a09cdbca-4e7b-4d9a-b479-515074964171"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}], "time_series": {"directory": "p1rhs7_1247_time_series"}} \ No newline at end of file diff --git a/tests/models/p1rhs7_1247.json.bak b/tests/models/p1rhs7_1247.json.bak index 79cd09a..36b48bd 100644 --- a/tests/models/p1rhs7_1247.json.bak +++ b/tests/models/p1rhs7_1247.json.bak @@ -1 +1 @@ -{"name": null, "description": null, "uuid": "46939f3b-e363-402b-96d5-075fea00bb3c", "data_format_version": "1.4.0", "components": [{"uuid": "b3ec0470-4645-4817-8d9e-36a62dd25e7b", "name": "", "limit_type": "min", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "base"}}, "value": {"value": 37.84531014537997, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}}, {"uuid": "6f2e6cad-94d8-43ba-82be-43800c8ff5c3", "name": "", "limit_type": "max", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "base"}}, "value": {"value": 41.82902700278839, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}}, {"uuid": "198717db-85ba-42fb-bb64-8404694680f4", "name": "", "x": 38.64060097099336, "y": -122.50688851789585, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "574ab810-c1b0-4662-8c4d-f32ab6893a36", "name": "p1rhs7_69", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "b3ec0470-4645-4817-8d9e-36a62dd25e7b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "6f2e6cad-94d8-43ba-82be-43800c8ff5c3"}}}], "nominal_voltage": {"value": 39.83716857408418, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "198717db-85ba-42fb-bb64-8404694680f4"}}}}, {"uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e", "name": "", "limit_type": "min", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "base"}}, "value": {"value": 6.839579963954902, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}}, {"uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4", "name": "", "limit_type": "max", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "base"}}, "value": {"value": 7.559535749634366, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}}, {"uuid": "43cd04c2-460c-452d-86bf-a5589f142291", "name": "", "x": 38.64000605387684, "y": -122.50715315149552, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "30052484-94f2-43a3-abb7-9314d4593c20", "name": "sb10_p1rhs7_1247_bus_10_6", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "43cd04c2-460c-452d-86bf-a5589f142291"}}}}, {"uuid": "03718c17-c4ff-4e1c-8455-8fcf4a4af180", "name": "", "x": 38.63991059999376, "y": -122.50713209215856, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ed5e3889-e8c8-4215-adb8-9880f8937da5", "name": "p1rdt6488-p1rhs7_1247x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "03718c17-c4ff-4e1c-8455-8fcf4a4af180"}}}}, {"uuid": "0488d677-5c3a-4447-9757-a609b80ee957", "name": "", "x": 38.64000458987126, "y": -122.50680575213045, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "23779a0d-9859-4591-b4ce-7ec704401d42", "name": "sb10_p1rhs7_1247_bus_10_7", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0488d677-5c3a-4447-9757-a609b80ee957"}}}}, {"uuid": "55ae0586-0c23-44a5-9795-611001c2b35b", "name": "", "x": 38.63990849507586, "y": -122.50663270624317, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1548dd91-bc3d-4a2c-903f-48e11159c558", "name": "p1rdt7711-p1rhs7_1247x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "55ae0586-0c23-44a5-9795-611001c2b35b"}}}}, {"uuid": "fef667d2-e160-4e42-93ec-3fe9b5fa8815", "name": "", "x": 38.64015019482659, "y": -122.50741272190496, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f4d9a6e8-eb1b-454c-ae94-2eb435218fb9", "name": "sb10_p1rhs7_1247_bus_10_4", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fef667d2-e160-4e42-93ec-3fe9b5fa8815"}}}}, {"uuid": "2b867617-7e8c-4db9-ade6-b774fb29b86d", "name": "", "x": 38.64000705978231, "y": -122.50739198857364, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "14208aa5-3197-4c90-adf9-3067dae9b5f9", "name": "p1rdt5342-p1rhs7_1247x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2b867617-7e8c-4db9-ade6-b774fb29b86d"}}}}, {"uuid": "d32bc420-6934-4d7e-91ab-1e3398b02d2c", "name": "", "x": 38.640146717948795, "y": -122.5065876467693, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2427b8de-af1a-44f8-9774-724e635057fb", "name": "sb10_p1rhs7_1247_bus_10_5", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d32bc420-6934-4d7e-91ab-1e3398b02d2c"}}}}, {"uuid": "e9c98454-f906-4403-becb-00deac9c5c8c", "name": "", "x": 38.64000266679855, "y": -122.50634979050211, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ec7726f8-0afb-4c35-8a1b-0691a8fb400d", "name": "p1rdt8583-p1rhs7_1247x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e9c98454-f906-4403-becb-00deac9c5c8c"}}}}, {"uuid": "08b140ca-c960-474e-ac23-6e6580d6298c", "name": "", "x": 38.640398325892065, "y": -122.5068899064944, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "001adbd4-6616-4dce-83d2-025e896ada51", "name": "sb10_p1rhs7_1247_node_10_7", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "08b140ca-c960-474e-ac23-6e6580d6298c"}}}}, {"uuid": "0783a135-88c7-4b30-86a9-f2f6557c594a", "name": "", "x": 38.64033927342312, "y": -122.50702059026854, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3856ea8d-83da-4d2e-8f66-fae6c69b5db1", "name": "sb10_p1rhs7_1247_bus_10_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0783a135-88c7-4b30-86a9-f2f6557c594a"}}}}, {"uuid": "07d60bfb-ce5e-4d51-9638-eb8860046b02", "name": "", "x": 38.64024290434973, "y": -122.50678240569646, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c975b603-30a6-4ed1-bbae-696d1c5b0a3d", "name": "sb10_p1rhs7_1247_bus_10_3", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "07d60bfb-ce5e-4d51-9638-eb8860046b02"}}}}, {"uuid": "7fd62588-3463-4a61-8c5d-1bb88b8c086a", "name": "", "x": 38.640245008643895, "y": -122.50728179394365, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6263cae0-e97a-4044-a130-e971a626d3c1", "name": "sb10_p1rhs7_1247_bus_10_2", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7fd62588-3463-4a61-8c5d-1bb88b8c086a"}}}}, {"uuid": "09d479e2-73cb-4c6e-9182-419e2c7d9217", "name": "", "x": 38.64044600709302, "y": -122.50688957976658, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16bb904e-b153-4b0a-97f5-53ad7c6606d8", "name": "sb10_p1rhs7_1247_node_10_6", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "b3ec0470-4645-4817-8d9e-36a62dd25e7b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "6f2e6cad-94d8-43ba-82be-43800c8ff5c3"}}}], "nominal_voltage": {"value": 39.83716857408418, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "09d479e2-73cb-4c6e-9182-419e2c7d9217"}}}}, {"uuid": "154210fc-9811-4963-880a-2605cc049534", "name": "", "x": 38.64052944919371, "y": -122.50688900799106, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ca7962b4-686c-4bee-af8d-f1851b835adb", "name": "sb10_p1rhs7_1247_node_10_5", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "b3ec0470-4645-4817-8d9e-36a62dd25e7b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "6f2e6cad-94d8-43ba-82be-43800c8ff5c3"}}}], "nominal_voltage": {"value": 39.83716857408418, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "154210fc-9811-4963-880a-2605cc049534"}}}}, {"uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc", "name": "", "limit_type": "min", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "base"}}, "value": {"value": 0.11408441319187004, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}}, {"uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5", "name": "", "limit_type": "max", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "base"}}, "value": {"value": 0.12609329879101427, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}}, {"uuid": "c9b5dc22-6b6c-4e4f-bb66-434e7a4937bf", "name": "", "x": 38.58930068802498, "y": -122.47407241728135, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3541a1a-9680-4baf-9b87-a1322cb1a16a", "name": "p1rdt4964lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c9b5dc22-6b6c-4e4f-bb66-434e7a4937bf"}}}}, {"uuid": "cececd48-9462-4a04-90f8-afe07e75e821", "name": "", "x": 38.58928688389361, "y": -122.47412342379597, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "02e86824-b793-4080-9401-c6995a365baf", "name": "p1rlv10170", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cececd48-9462-4a04-90f8-afe07e75e821"}}}}, {"uuid": "b99a2ad7-5611-486b-890e-ec585d6cdc15", "name": "", "x": 38.58730261534203, "y": -122.47493972983303, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ab731358-e17f-4c48-b6f8-c7bb4c7701de", "name": "p1rdt4980lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b99a2ad7-5611-486b-890e-ec585d6cdc15"}}}}, {"uuid": "88aed81c-9aee-49c7-b399-6d35c3018dbd", "name": "", "x": 38.586999682758396, "y": -122.47455116112062, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "58f2b2c3-4f6f-4fd2-abb9-42ff665692bd", "name": "p1rlv10189", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "88aed81c-9aee-49c7-b399-6d35c3018dbd"}}}}, {"uuid": "d25f087f-69b4-4209-ac90-8818cc55484e", "name": "", "x": 38.5874921997227, "y": -122.47522897778698, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6b4caeee-6304-4a25-a7d8-44c6014b5e37", "name": "p1rlv10574", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d25f087f-69b4-4209-ac90-8818cc55484e"}}}}, {"uuid": "d4aaf336-5d7e-46b9-9bb6-f7d1ed0c4e09", "name": "", "x": 38.587371992400946, "y": -122.47517995477224, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aad9ea92-9403-4ac0-9aaf-7e845b8c7bb5", "name": "p1rlv10596", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d4aaf336-5d7e-46b9-9bb6-f7d1ed0c4e09"}}}}, {"uuid": "5b862a31-20f0-4f36-926e-88ecbddd6658", "name": "", "x": 38.58881837779083, "y": -122.47343065419352, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0375d197-ccd2-4ed8-9439-857b700cefb8", "name": "p1rdt5017lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5b862a31-20f0-4f36-926e-88ecbddd6658"}}}}, {"uuid": "609e696a-a153-4e81-a0de-294f1949fda2", "name": "", "x": 38.58885966670059, "y": -122.47344264204159, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3317d7c2-2588-426d-91fc-3d765b932da6", "name": "p1rlv10262", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "609e696a-a153-4e81-a0de-294f1949fda2"}}}}, {"uuid": "8925aa98-b97a-4609-928a-4c2fb1511718", "name": "", "x": 38.62911239194669, "y": -122.48794713837246, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7e33e473-8d5b-4704-bdab-56032991f94e", "name": "p1rdt5126lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8925aa98-b97a-4609-928a-4c2fb1511718"}}}}, {"uuid": "83e7ddaa-1339-44f6-924d-5a5f6a3cf8cf", "name": "", "x": 38.6290864193847, "y": -122.48790451626458, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8f7116b9-96c1-42c8-850f-7787f5fd0f96", "name": "p1rlv10491", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "83e7ddaa-1339-44f6-924d-5a5f6a3cf8cf"}}}}, {"uuid": "84da10da-2cca-45f7-9864-c2b1098caa40", "name": "", "x": 38.625434851806375, "y": -122.44516017839125, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dd4b469b-001b-4914-8e51-e98fe3f6babb", "name": "p1rdm10619", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "84da10da-2cca-45f7-9864-c2b1098caa40"}}}}, {"uuid": "791f4ebc-b1a0-4617-b265-6f27b679cd92", "name": "", "x": 38.625158815750815, "y": -122.44586307086524, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "31f26b28-fc9d-4b3d-b204-cf40f3478c44", "name": "p1rlv10521", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "791f4ebc-b1a0-4617-b265-6f27b679cd92"}}}}, {"uuid": "905821af-0745-45f1-9947-ecdae59a1230", "name": "", "x": 38.625299188790116, "y": -122.44505783200565, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e28a5f3a-4447-469a-85dd-e232d8c6d728", "name": "p1rdm10620", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "905821af-0745-45f1-9947-ecdae59a1230"}}}}, {"uuid": "fc3d809d-3c65-4bcc-8227-0daa8d5f70f7", "name": "", "x": 38.62519279357018, "y": -122.44542626681253, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "73ada6ad-ace7-46c1-80f7-2cb33cf4cdb3", "name": "p1rlv10641", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fc3d809d-3c65-4bcc-8227-0daa8d5f70f7"}}}}, {"uuid": "fe8f593f-9830-4c8d-8ac2-c631589cabcb", "name": "", "x": 38.625591389135096, "y": -122.44526633659068, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5f114a56-98d7-4fe8-b0b1-b8c4bc791cf9", "name": "p1rdt5140lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fe8f593f-9830-4c8d-8ac2-c631589cabcb"}}}}, {"uuid": "c0c3cf78-7bf0-4327-987d-79699acfeb78", "name": "", "x": 38.62571524353723, "y": -122.44537629052095, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e09d217e-44a5-4013-8d48-8546d6bb1dc3", "name": "p1rdm10621", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c0c3cf78-7bf0-4327-987d-79699acfeb78"}}}}, {"uuid": "b087818c-f0c4-44e8-86b3-a358f5f73403", "name": "", "x": 38.62565276187416, "y": -122.44550314021144, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "07f95ba5-92dd-465f-a38d-8e878243262b", "name": "p1rlv20071", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b087818c-f0c4-44e8-86b3-a358f5f73403"}}}}, {"uuid": "8efabcfe-13b9-41a1-adeb-db0ab55a0905", "name": "", "x": 38.622332296573816, "y": -122.44976008456518, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e071635-4071-470d-be09-4484cb90441a", "name": "p1rdt5142lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8efabcfe-13b9-41a1-adeb-db0ab55a0905"}}}}, {"uuid": "fe5c7977-cf01-48d0-8145-1e49d6d26df0", "name": "", "x": 38.62217684357621, "y": -122.44988366265912, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35d47036-a044-4c67-b5b5-0006e2a3b68e", "name": "p1rlv10523", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fe5c7977-cf01-48d0-8145-1e49d6d26df0"}}}}, {"uuid": "919ab874-ec10-4b43-841d-de5560c6f8ce", "name": "", "x": 38.62245506643117, "y": -122.44964029908394, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a5717e0-080e-46ae-918a-64fe4fcba5d7", "name": "p1rlv10616", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "919ab874-ec10-4b43-841d-de5560c6f8ce"}}}}, {"uuid": "2108dc95-1071-454c-a014-d592b62560ac", "name": "", "x": 38.58825755415666, "y": -122.46710557327793, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ec20ad2-b04f-43fc-ad8d-d41746549a57", "name": "p1rdt5153lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2108dc95-1071-454c-a014-d592b62560ac"}}}}, {"uuid": "8ae7ce00-9a27-47f2-9b8b-068f0cd24e76", "name": "", "x": 38.58776776322457, "y": -122.46703633124763, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a302271d-4cf3-45ff-9308-b9cf31fbefa3", "name": "p1rlv10538", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8ae7ce00-9a27-47f2-9b8b-068f0cd24e76"}}}}, {"uuid": "cae2d3e5-816f-4b6b-958a-6c6d061dfe81", "name": "", "x": 38.58793840849323, "y": -122.4669087674479, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cfbe5665-c020-455a-addc-d3f9514735ed", "name": "p1rlv10586", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cae2d3e5-816f-4b6b-958a-6c6d061dfe81"}}}}, {"uuid": "b2f0ad91-48b4-488d-b58e-a9a570478b91", "name": "", "x": 38.58801998355576, "y": -122.46701150268488, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b91354e-ce50-44d0-a959-fa451bb9cf20", "name": "p1rlv10610", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b2f0ad91-48b4-488d-b58e-a9a570478b91"}}}}, {"uuid": "daf9b693-80a3-42ee-8706-c161353b3bee", "name": "", "x": 38.62299459252021, "y": -122.44285578875113, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "85351f49-cb19-4f71-a6ae-a21f5a48af6f", "name": "p1rdt5155lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "daf9b693-80a3-42ee-8706-c161353b3bee"}}}}, {"uuid": "7717760f-23fb-40cd-a9b0-f0188f35b9f2", "name": "", "x": 38.62296860365152, "y": -122.44281318670158, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4829cd2f-7e61-4386-89ce-89d77d5ef5cf", "name": "p1rlv10540", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7717760f-23fb-40cd-a9b0-f0188f35b9f2"}}}}, {"uuid": "9413b231-e7d1-4a46-adac-dcb6f32db7d4", "name": "", "x": 38.623416278049106, "y": -122.44435741173649, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ba7e3a6b-f62f-432f-afe7-2ebbfc9abd59", "name": "p1rdt5159lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9413b231-e7d1-4a46-adac-dcb6f32db7d4"}}}}, {"uuid": "1c49be6d-fc4c-418f-9b44-644a6e2a42e2", "name": "", "x": 38.62339028972311, "y": -122.44431480889065, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6c722b89-fdaf-416f-863e-02b443375ba1", "name": "p1rlv10544", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1c49be6d-fc4c-418f-9b44-644a6e2a42e2"}}}}, {"uuid": "57af24fc-2f2e-4145-b371-ee77999bac6c", "name": "", "x": 38.62398776024399, "y": -122.44276641347568, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48efdcb9-083c-4e17-a1d2-acb1388f085e", "name": "p1rdt5172lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "57af24fc-2f2e-4145-b371-ee77999bac6c"}}}}, {"uuid": "1d70710d-9a07-4242-a38f-5d47bc190b51", "name": "", "x": 38.62338766087452, "y": -122.44294734474045, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c8a10822-398f-441e-a5ca-73303d832183", "name": "p1rlv10563", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d70710d-9a07-4242-a38f-5d47bc190b51"}}}}, {"uuid": "eb9ecf04-f209-4a45-9ca6-f9115d073e72", "name": "", "x": 38.618803618131444, "y": -122.45181229136102, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dd4155b2-ca55-41d7-bd35-98a5eec8c39a", "name": "p1rdt5179lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eb9ecf04-f209-4a45-9ca6-f9115d073e72"}}}}, {"uuid": "ef045117-9d8f-4b4a-a616-40bcd5391aa5", "name": "", "x": 38.61925559252727, "y": -122.4515026734116, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "94677ede-fd5c-4fbb-bfcd-98cf67b56913", "name": "p1rlv10573", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef045117-9d8f-4b4a-a616-40bcd5391aa5"}}}}, {"uuid": "fd077f51-6fff-413f-bf0e-4488154496fc", "name": "", "x": 38.61839344506758, "y": -122.45214101800151, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a0431d17-75da-48c1-965c-875f61b0e9bf", "name": "p1rlv10583", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fd077f51-6fff-413f-bf0e-4488154496fc"}}}}, {"uuid": "be95eaa2-f600-4067-97f2-e6070d375414", "name": "", "x": 38.62221649276758, "y": -122.44627684656544, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ae26acb3-c2c9-479c-9d19-c30bf00aa8c5", "name": "p1rdt5180lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be95eaa2-f600-4067-97f2-e6070d375414"}}}}, {"uuid": "be1285dd-72ff-4444-817f-574f0346a2c9", "name": "", "x": 38.622228136819786, "y": -122.44632961498499, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25141e20-0a65-4905-b37f-954ed1a8751c", "name": "p1rlv10576", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be1285dd-72ff-4444-817f-574f0346a2c9"}}}}, {"uuid": "10c2c882-6746-444f-b809-677b728156cf", "name": "", "x": 38.58486127149263, "y": -122.47507613100927, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3bbde2e8-42c0-486b-9759-78898d177f93", "name": "p1rdt5183lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10c2c882-6746-444f-b809-677b728156cf"}}}}, {"uuid": "560205af-2471-40f9-8e3e-65f51ade10de", "name": "", "x": 38.584860090382186, "y": -122.47502224179047, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cdfa726f-5606-4ae2-b358-ad664dd7b0e3", "name": "p1rlv10582", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "560205af-2471-40f9-8e3e-65f51ade10de"}}}}, {"uuid": "3337f64c-470e-47ce-a97e-4d4570af0515", "name": "", "x": 38.6246895952918, "y": -122.44633371298471, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1656cc28-8a5b-40da-887f-25605dd336aa", "name": "p1rdt5184lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3337f64c-470e-47ce-a97e-4d4570af0515"}}}}, {"uuid": "6bd43a1d-48a8-4497-b3e4-8d0ec3aab2bc", "name": "", "x": 38.624682565233414, "y": -122.4461539331612, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "53019a8a-b453-4add-9d2d-e4ab380fce67", "name": "p1rlv10589", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6bd43a1d-48a8-4497-b3e4-8d0ec3aab2bc"}}}}, {"uuid": "ddc1bf24-6112-491d-b9b2-c3ffeaac64de", "name": "", "x": 38.624602168391775, "y": -122.44630389385829, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "feb19590-c5f4-4982-9e99-20599f08cfe7", "name": "p1rlv10600", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ddc1bf24-6112-491d-b9b2-c3ffeaac64de"}}}}, {"uuid": "41225cc6-cdcb-463a-a44f-1fbec5c8f0f3", "name": "", "x": 38.62484662068028, "y": -122.44654326007226, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "374d5417-b2c4-4d16-9b91-d2f519921fd8", "name": "p1rlv10621", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "41225cc6-cdcb-463a-a44f-1fbec5c8f0f3"}}}}, {"uuid": "463f4f85-69a4-45bc-87ec-d0f8a40b0c82", "name": "", "x": 38.649308955445846, "y": -122.40285111885804, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf05c1bb-39cc-48b3-a576-18913e0cff13", "name": "p1rdt5195lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "463f4f85-69a4-45bc-87ec-d0f8a40b0c82"}}}}, {"uuid": "4935e47a-85c4-40c5-83a4-8c706d58814d", "name": "", "x": 38.649342089627496, "y": -122.40283537845332, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1b175fcb-d1ee-44eb-8f89-826e40c5db1d", "name": "p1rlv10615", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4935e47a-85c4-40c5-83a4-8c706d58814d"}}}}, {"uuid": "4d8947e5-f3a0-43f2-bb3c-c156b337ea40", "name": "", "x": 38.64914651543566, "y": -122.40280650016945, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3184f056-3b5f-403d-86a0-f9b28d6bb3e3", "name": "p1rlv10634", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d8947e5-f3a0-43f2-bb3c-c156b337ea40"}}}}, {"uuid": "26aa33e2-1edf-424f-b548-410cbaee9b20", "name": "", "x": 38.58803256102546, "y": -122.4709126113251, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "03e7bfdb-ff8b-4142-95ef-8d848ff5d2db", "name": "p1rdt5200lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "26aa33e2-1edf-424f-b548-410cbaee9b20"}}}}, {"uuid": "eedd822e-ac93-4283-b769-4a115d88068e", "name": "", "x": 38.58800658229211, "y": -122.47087001955629, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32406d7d-51f9-4c16-900b-526985e5f62b", "name": "p1rlv10627", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eedd822e-ac93-4283-b769-4a115d88068e"}}}}, {"uuid": "5e69e0e7-a169-409b-aa08-29275566fae9", "name": "", "x": 38.62310262007371, "y": -122.44472743619623, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b8162a8c-5339-4f42-bd7a-b6dbc5ff463b", "name": "p1rdt5201lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5e69e0e7-a169-409b-aa08-29275566fae9"}}}}, {"uuid": "8a684d6a-e879-403d-b98a-145e2c82abb8", "name": "", "x": 38.623076631881446, "y": -122.44468483339944, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e183b3e8-d995-4f1e-baee-8d9d4add157e", "name": "p1rlv10629", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8a684d6a-e879-403d-b98a-145e2c82abb8"}}}}, {"uuid": "009b7291-1ad4-4e31-812f-20a22582b7f8", "name": "", "x": 38.647579222155, "y": -122.40883933742933, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "39eaedd7-75b6-449f-8ff6-6e31f6e74504", "name": "p1rdt5202lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "009b7291-1ad4-4e31-812f-20a22582b7f8"}}}}, {"uuid": "737a5433-f6cd-4820-bed5-b01766e07a38", "name": "", "x": 38.64738178775039, "y": -122.40899959560872, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8d60a935-dc9b-48ea-8ee7-9b682452035e", "name": "p1rlv10630", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "737a5433-f6cd-4820-bed5-b01766e07a38"}}}}, {"uuid": "a1331dcf-bb83-4354-a0d1-9adaf14bd4a2", "name": "", "x": 38.645656291690415, "y": -122.4075034535507, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "599a2995-33d5-4bcc-8cd3-585ea37577cd", "name": "p1rdt5206lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a1331dcf-bb83-4354-a0d1-9adaf14bd4a2"}}}}, {"uuid": "76105b9d-ef6e-4669-aa1a-d7354b4c1846", "name": "", "x": 38.64561400003638, "y": -122.40750498256921, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e9510bd0-2bba-4522-bfbe-20b94ea400b6", "name": "p1rlv10637", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "76105b9d-ef6e-4669-aa1a-d7354b4c1846"}}}}, {"uuid": "3b3ae9e8-ee45-4b39-a9d2-b653896ffc6e", "name": "", "x": 38.65641154150713, "y": -122.39587823120766, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c650eda9-132b-4419-a055-ad68037c7772", "name": "p1rdt5218lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3b3ae9e8-ee45-4b39-a9d2-b653896ffc6e"}}}}, {"uuid": "f8592191-94d2-423d-a9cc-66bf4448c219", "name": "", "x": 38.656425923289945, "y": -122.39592902455765, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8198c1c5-67e0-49b9-b11a-1f266f7f4bcb", "name": "p1rlv10663", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f8592191-94d2-423d-a9cc-66bf4448c219"}}}}, {"uuid": "cc50144a-f184-4913-a41b-8e0739907a56", "name": "", "x": 38.641472751242716, "y": -122.48093037801921, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5f252d81-66ee-40a6-bce7-2891e06b39e4", "name": "p1rdt5236lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc50144a-f184-4913-a41b-8e0739907a56"}}}}, {"uuid": "6a6587af-c013-4f7f-a20c-cca2a39b8c90", "name": "", "x": 38.64148709617754, "y": -122.48098117829157, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d3d48c0e-704d-4205-94a2-ee74be7ae350", "name": "p1rlv10720", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a6587af-c013-4f7f-a20c-cca2a39b8c90"}}}}, {"uuid": "69d6c981-12fa-4fb6-b646-c5cc5e4d9eaf", "name": "", "x": 38.641937121819915, "y": -122.50369495559332, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e01069aa-388b-4362-9d02-a164f173dc20", "name": "p1rdt5342lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "69d6c981-12fa-4fb6-b646-c5cc5e4d9eaf"}}}}, {"uuid": "dc80310e-0c48-4dc4-ba11-988bd5a787f0", "name": "", "x": 38.64182806242219, "y": -122.50347514079304, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75dbf8f0-4cb6-49b7-a2a5-f98e9ff4b8df", "name": "p1rlv10955", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dc80310e-0c48-4dc4-ba11-988bd5a787f0"}}}}, {"uuid": "f9149994-925b-428c-8a33-66b8460df8e8", "name": "", "x": 38.642018719214704, "y": -122.50380705470455, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0a8fc823-6fe8-4a3b-9437-68aa751f5e3b", "name": "p1rlv11048", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f9149994-925b-428c-8a33-66b8460df8e8"}}}}, {"uuid": "86ec09c9-13eb-44cd-a1b1-3711d57cfccb", "name": "", "x": 38.642205431006985, "y": -122.4576909223735, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "34a1276e-c702-4c69-b7b1-566d400da2de", "name": "p1rdt5472lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "86ec09c9-13eb-44cd-a1b1-3711d57cfccb"}}}}, {"uuid": "c8226150-c622-4980-9f33-95cb9cf66220", "name": "", "x": 38.64217944750302, "y": -122.4576483036143, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f949a06a-817e-4666-95bb-9536ce06a694", "name": "p1rlv11380", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c8226150-c622-4980-9f33-95cb9cf66220"}}}}, {"uuid": "d51b82c8-7885-4679-b8ed-12a631d090e7", "name": "", "x": 38.63960343978653, "y": -122.45649923239668, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5d181674-9355-488b-8a3f-5b7c844c35a5", "name": "p1rdt5475lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d51b82c8-7885-4679-b8ed-12a631d090e7"}}}}, {"uuid": "c119fba5-939c-479d-8bec-f034962dca28", "name": "", "x": 38.63981590397471, "y": -122.45628682931535, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e0c23aea-471f-4d10-9500-1bc14a67d7e7", "name": "p1rlv11384", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c119fba5-939c-479d-8bec-f034962dca28"}}}}, {"uuid": "f9b337b1-5557-4cd2-90b5-fe2127096eaf", "name": "", "x": 38.63963394395313, "y": -122.45652552675769, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7f512d86-c9d9-4f58-9d5a-418d0732dc94", "name": "p1rlv11386", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f9b337b1-5557-4cd2-90b5-fe2127096eaf"}}}}, {"uuid": "ee00163c-6526-4f99-80db-96be6a310440", "name": "", "x": 38.63927702838603, "y": -122.4566815679821, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9fd316b0-fd98-4193-9c1b-aaa7d92a4284", "name": "p1rlv11397", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ee00163c-6526-4f99-80db-96be6a310440"}}}}, {"uuid": "68f4463f-0f9f-4317-a2f9-fbe04b0afa9d", "name": "", "x": 38.639428183564455, "y": -122.46174457730311, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0888f4c5-e037-4891-99fb-fd43934ffae0", "name": "p1rdt5476lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "68f4463f-0f9f-4317-a2f9-fbe04b0afa9d"}}}}, {"uuid": "49097a9b-5c02-4d19-9fce-192f24b100ec", "name": "", "x": 38.639434265073014, "y": -122.46179953026234, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2115e8bb-fe49-49ad-8687-68feca212557", "name": "p1rlv11385", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "49097a9b-5c02-4d19-9fce-192f24b100ec"}}}}, {"uuid": "9f133821-96eb-4579-aee6-925be1a09527", "name": "", "x": 38.642101120835456, "y": -122.45608173877747, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fafd64c3-efe5-4684-b06f-44e4c8555aa4", "name": "p1rdt5477lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9f133821-96eb-4579-aee6-925be1a09527"}}}}, {"uuid": "1cf42564-0cee-4e41-85fc-b6e4694082f9", "name": "", "x": 38.64166518451146, "y": -122.45668651807028, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cbca8c57-0da4-4368-9821-7a9ca4282173", "name": "p1rlv11387", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1cf42564-0cee-4e41-85fc-b6e4694082f9"}}}}, {"uuid": "c753ea66-6b44-4f63-9692-64bd0a9737e0", "name": "", "x": 38.63719096576592, "y": -122.45830192704182, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5107bc9c-f463-49f6-a92f-23c5730475e2", "name": "p1rdt5478lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c753ea66-6b44-4f63-9692-64bd0a9737e0"}}}}, {"uuid": "6e9acac3-2384-45c3-b797-5bcce4603394", "name": "", "x": 38.63771659092773, "y": -122.4583249236366, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "12377bf0-f258-4c29-ab26-e938c95ee25c", "name": "p1rlv11388", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6e9acac3-2384-45c3-b797-5bcce4603394"}}}}, {"uuid": "38e78d90-477b-4736-9dde-04ab72558727", "name": "", "x": 38.63670708849592, "y": -122.4582865622578, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "97aa01fe-2e60-4617-8c89-d36f425087fe", "name": "p1rlv11398", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "38e78d90-477b-4736-9dde-04ab72558727"}}}}, {"uuid": "4f990b5f-70ec-4d45-b79a-ee56910b1e0d", "name": "", "x": 38.64171847326658, "y": -122.45537480795159, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "004f56b2-ec94-4189-91b8-46b4af22faa6", "name": "p1rdm11569", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4f990b5f-70ec-4d45-b79a-ee56910b1e0d"}}}}, {"uuid": "b46ddb8c-258a-46e0-9cc5-ce3594b0f2a0", "name": "", "x": 38.64245774536079, "y": -122.45464667599991, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9b6420b1-3456-42fc-9266-c2b84e063cec", "name": "p1rlv11390", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b46ddb8c-258a-46e0-9cc5-ce3594b0f2a0"}}}}, {"uuid": "94a3ded1-2e9b-42c2-9115-27ab1198f1ad", "name": "", "x": 38.641798080115834, "y": -122.45558638857214, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "44ac9e38-8ae3-4102-822b-1c638a6c878a", "name": "p1rdt5480lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "94a3ded1-2e9b-42c2-9115-27ab1198f1ad"}}}}, {"uuid": "9c167415-a423-4f44-bf0d-2c02116b5458", "name": "", "x": 38.64189515756268, "y": -122.45575404043835, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8be902f6-4cca-4ce5-9f73-a1f96c65d8ef", "name": "p1rdm11570", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9c167415-a423-4f44-bf0d-2c02116b5458"}}}}, {"uuid": "b944b2db-b9e5-412c-9cf9-8b7a3f920690", "name": "", "x": 38.64223524158617, "y": -122.45524587802178, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a215d7dd-8081-4355-9c38-4fd3d2c859c7", "name": "p1rlv11401", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b944b2db-b9e5-412c-9cf9-8b7a3f920690"}}}}, {"uuid": "1b663de6-20e1-48d3-b3c9-6f141c4a5ca7", "name": "", "x": 38.64020129527885, "y": -122.45644080950349, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f213ee9e-6ae7-4e82-9f25-6fc456f45576", "name": "p1rdt5481lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1b663de6-20e1-48d3-b3c9-6f141c4a5ca7"}}}}, {"uuid": "eab215e8-2ae0-46fd-a218-fd08beaa74e3", "name": "", "x": 38.64014090557112, "y": -122.45641076765583, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e740a352-ac8f-4ae2-ace3-254fccd7f96f", "name": "p1rlv11392", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eab215e8-2ae0-46fd-a218-fd08beaa74e3"}}}}, {"uuid": "22a6c911-8788-4f98-b55b-a8a2368bf128", "name": "", "x": 38.640303433007105, "y": -122.45647848222762, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "996d3e44-142c-42fa-bf4f-2bd1777122dd", "name": "p1rlv11394", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "22a6c911-8788-4f98-b55b-a8a2368bf128"}}}}, {"uuid": "7db0ae48-3ebd-433d-9568-05f0c398309d", "name": "", "x": 38.64168447824798, "y": -122.45542011758508, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8a73d544-9f33-49d9-b648-c806addf3c06", "name": "p1rdt5483lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7db0ae48-3ebd-433d-9568-05f0c398309d"}}}}, {"uuid": "81ff1e3e-2885-4592-9965-5945d231f979", "name": "", "x": 38.64195529639681, "y": -122.45512160027936, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "29922f55-f36a-4b9e-8836-5f9dadd641b7", "name": "p1rlv11395", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "81ff1e3e-2885-4592-9965-5945d231f979"}}}}, {"uuid": "288eb15e-e98b-4fdb-824b-6b63988c8235", "name": "", "x": 38.6393583769313, "y": -122.45589692178642, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "40eaefce-482f-4a89-bec1-2c11bac2bfb7", "name": "p1rdt5485lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "288eb15e-e98b-4fdb-824b-6b63988c8235"}}}}, {"uuid": "9a233f64-0a3f-4005-ac29-8df3dc67c147", "name": "", "x": 38.63937273269481, "y": -122.45594771545282, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "68a9eead-8197-4e82-a444-2a4544ec9ddb", "name": "p1rlv11399", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9a233f64-0a3f-4005-ac29-8df3dc67c147"}}}}, {"uuid": "67bfd210-882e-4eb2-b12d-7335778f6e07", "name": "", "x": 38.57143813832739, "y": -122.49015904841082, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "28a6e44b-c6c7-4556-b4d8-d55359391c66", "name": "p1rdt5650lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "67bfd210-882e-4eb2-b12d-7335778f6e07"}}}}, {"uuid": "e6ad383e-e706-44b6-8583-c21c9e8f308d", "name": "", "x": 38.57142432703484, "y": -122.49021003925405, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "834a5733-5264-4adf-861a-25e494df3e37", "name": "p1rlv11671", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e6ad383e-e706-44b6-8583-c21c9e8f308d"}}}}, {"uuid": "3aaeb5f6-c3be-4c8d-ac2c-284fc845d759", "name": "", "x": 38.65464557723489, "y": -122.39724791960451, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "38d1de19-1f51-4875-acc2-a75e3d1a290e", "name": "p1rdt5653lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3aaeb5f6-c3be-4c8d-ac2c-284fc845d759"}}}}, {"uuid": "196dcfb1-cbe1-481a-b575-c37dc4ed0da8", "name": "", "x": 38.65508992916787, "y": -122.39723667691878, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "45f2a901-e4f7-4055-a3e2-b60c61d5033e", "name": "p1rlv11674", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "196dcfb1-cbe1-481a-b575-c37dc4ed0da8"}}}}, {"uuid": "63fded38-9e61-45e7-8ae6-58ed56c3a1c9", "name": "", "x": 38.57263362388283, "y": -122.495683769354, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "87e8c57e-67ff-439c-b28b-0fbdbfd62ea6", "name": "p1rdt5656lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "63fded38-9e61-45e7-8ae6-58ed56c3a1c9"}}}}, {"uuid": "59d4774b-339b-4dc2-9d3d-807731c082ae", "name": "", "x": 38.5726198101849, "y": -122.49573476001369, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8b2f121a-2202-43c0-8684-81913a5d6ea9", "name": "p1rlv11677", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59d4774b-339b-4dc2-9d3d-807731c082ae"}}}}, {"uuid": "c8f6dffd-c572-4d99-b2a4-19421d74334c", "name": "", "x": 38.57280585377797, "y": -122.4929323788313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ea73a91a-b052-486e-810b-1a5ad281e07b", "name": "p1rdt5662lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c8f6dffd-c572-4d99-b2a4-19421d74334c"}}}}, {"uuid": "d4bd3e1e-9577-4201-9f8e-450e5cb4257e", "name": "", "x": 38.57242796617633, "y": -122.49307054728973, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "02aef971-5f4a-4ca8-aa33-cce34517bd44", "name": "p1rlv11684", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d4bd3e1e-9577-4201-9f8e-450e5cb4257e"}}}}, {"uuid": "1c8ccecf-94f0-4086-9894-43ca68c27898", "name": "", "x": 38.56680617078412, "y": -122.49719640898832, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16a67a88-5d11-4eca-85fe-38c948ad362c", "name": "p1rdt5663lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1c8ccecf-94f0-4086-9894-43ca68c27898"}}}}, {"uuid": "da50b7f4-c1bf-47df-ab82-73a5722737b9", "name": "", "x": 38.5668199513191, "y": -122.49730717896358, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cda8e361-98b6-49bd-a3ff-30a036a3dc6f", "name": "p1rlv11686", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "da50b7f4-c1bf-47df-ab82-73a5722737b9"}}}}, {"uuid": "b4ec8b1c-107b-490d-9bb4-eb8aa4f0a2a2", "name": "", "x": 38.56665994983674, "y": -122.49716304017915, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e5b71ca5-a7ab-42f7-824a-bc43fc1708cc", "name": "p1rdm11909", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b4ec8b1c-107b-490d-9bb4-eb8aa4f0a2a2"}}}}, {"uuid": "23b77dd8-f10c-4624-953a-3e440aa570f4", "name": "", "x": 38.566580963860986, "y": -122.49765717235252, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "449098c3-4f65-4350-863f-4b7bc1f14493", "name": "p1rlv15645", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "23b77dd8-f10c-4624-953a-3e440aa570f4"}}}}, {"uuid": "1ba63c10-373f-4350-b961-c90fd652abb4", "name": "", "x": 38.5707010215685, "y": -122.51444963387745, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6d456893-4d89-455a-b1a5-4863aad6293a", "name": "p1rdt5728lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1ba63c10-373f-4350-b961-c90fd652abb4"}}}}, {"uuid": "1f21215a-9d08-4812-8efd-536b0eded845", "name": "", "x": 38.57009391258443, "y": -122.51433495859402, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f0ba1408-17da-4678-8b04-90c616c3fb48", "name": "p1rlv11779", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1f21215a-9d08-4812-8efd-536b0eded845"}}}}, {"uuid": "d07cefa0-6a4a-4ea1-833c-1f8c7239b2ec", "name": "", "x": 38.57127534957151, "y": -122.51454511366566, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3890375-c01d-44d2-93f9-8d9d60da8852", "name": "p1rlv11783", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d07cefa0-6a4a-4ea1-833c-1f8c7239b2ec"}}}}, {"uuid": "65b9e11a-d035-49fe-9c2f-a18adc520bfa", "name": "", "x": 38.56955818331602, "y": -122.51459989092113, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "95f81d7a-a6af-4843-bfa1-002abc7ff870", "name": "p1rdt5729lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65b9e11a-d035-49fe-9c2f-a18adc520bfa"}}}}, {"uuid": "03cf9cc3-74d3-41be-ac9e-4c958be1448f", "name": "", "x": 38.56953222036641, "y": -122.51455729408103, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6e9a574d-9537-417a-a811-e22d84b8ea53", "name": "p1rlv11780", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "03cf9cc3-74d3-41be-ac9e-4c958be1448f"}}}}, {"uuid": "0a193e3d-f76a-4d4c-a33b-8d6eb8250e44", "name": "", "x": 38.57213402094206, "y": -122.51802514483155, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2dd206bc-965d-46c9-8fdb-8c158c7bba05", "name": "p1rdt5730lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a193e3d-f76a-4d4c-a33b-8d6eb8250e44"}}}}, {"uuid": "0198df5e-1335-4d36-b7fa-ea83c51eda03", "name": "", "x": 38.57199490295793, "y": -122.51856958078595, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b66df0bc-6159-42fa-bf49-b8ad17d0e6aa", "name": "p1rlv11784", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0198df5e-1335-4d36-b7fa-ea83c51eda03"}}}}, {"uuid": "1dd4f217-6d64-4bf3-be52-b765773001a9", "name": "", "x": 38.572056756934636, "y": -122.51827070037027, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b15fc66-89d9-483b-9c9f-9b0f39a63b29", "name": "p1rlv11786", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1dd4f217-6d64-4bf3-be52-b765773001a9"}}}}, {"uuid": "3142c953-b8bb-4934-aa7e-9394d697aafe", "name": "", "x": 38.572019292356316, "y": -122.51792656501027, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "64ee7f4c-b91a-4a25-b85d-a91b83777c1f", "name": "p1rdm12071", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3142c953-b8bb-4934-aa7e-9394d697aafe"}}}}, {"uuid": "ea02cc30-f701-4e2e-af04-30113338ce57", "name": "", "x": 38.571920919935685, "y": -122.51811089442202, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "28fd9f7c-0195-4529-a972-aa60eced47d2", "name": "p1rlv11781", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea02cc30-f701-4e2e-af04-30113338ce57"}}}}, {"uuid": "bb99e5fd-69c7-462b-8027-3c89a73aaa07", "name": "", "x": 38.56688129837257, "y": -122.51477378591451, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6e414162-eda7-4cf2-9116-fc24af9461bf", "name": "p1rdt5731lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bb99e5fd-69c7-462b-8027-3c89a73aaa07"}}}}, {"uuid": "a7bd841c-64ad-46a9-9b40-c7c407b24606", "name": "", "x": 38.5669221751359, "y": -122.51444813822336, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "496fc854-bbf8-463b-b16c-12dd1b444cc6", "name": "p1rlv11782", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a7bd841c-64ad-46a9-9b40-c7c407b24606"}}}}, {"uuid": "9b3e1b1d-5f5a-4ed6-bba2-f666acf4a2f6", "name": "", "x": 38.56702296960097, "y": -122.51484921518147, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7103c2f0-8160-434f-b4b3-edfbd7e97464", "name": "p1rdm12075", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9b3e1b1d-5f5a-4ed6-bba2-f666acf4a2f6"}}}}, {"uuid": "72915b72-842d-4d23-8777-a66df68ae209", "name": "", "x": 38.5670581599183, "y": -122.51464236147093, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ed0eb774-fcc3-417f-a8a4-fbdb825cc106", "name": "p1rlv11785", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "72915b72-842d-4d23-8777-a66df68ae209"}}}}, {"uuid": "ac2ebf07-87cc-46ac-affc-3aad7a0927ef", "name": "", "x": 38.57345429314894, "y": -122.51994138004522, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9974869d-7d87-4a27-9606-076cd7799953", "name": "p1rdt5840lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ac2ebf07-87cc-46ac-affc-3aad7a0927ef"}}}}, {"uuid": "dc36d120-77b5-4b62-95f8-a90964499200", "name": "", "x": 38.57328942198139, "y": -122.51998442674298, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1dfd848-b639-41b5-ad95-2c03a51bd36b", "name": "p1rlv12028", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dc36d120-77b5-4b62-95f8-a90964499200"}}}}, {"uuid": "0c5bf3c3-b2bf-4b42-95ef-eb2a0f8846dd", "name": "", "x": 38.573586478514756, "y": -122.51990209164686, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fc4d79bb-8ba3-4146-9d50-16db48ffec22", "name": "p1rlv12157", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0c5bf3c3-b2bf-4b42-95ef-eb2a0f8846dd"}}}}, {"uuid": "b2724222-42d6-4b39-9bdc-a131b20c18d3", "name": "", "x": 38.61540289404265, "y": -122.4340916885271, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "751d2f2e-bb6f-4ca6-9e86-0e2b5ff3f92a", "name": "p1rdt5923lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b2724222-42d6-4b39-9bdc-a131b20c18d3"}}}}, {"uuid": "f3ca5954-1325-4b71-ab86-ab13dee31042", "name": "", "x": 38.615385277507826, "y": -122.43359039737986, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "df9d9de2-6929-48a4-a390-c0e2f129b374", "name": "p1rlv12214", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f3ca5954-1325-4b71-ab86-ab13dee31042"}}}}, {"uuid": "00db6112-34c3-46a6-abeb-4f179fbbd1a9", "name": "", "x": 38.615361354746774, "y": -122.43423382325552, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c4d26673-c304-41de-8b5b-149552601ba4", "name": "p1rlv12217", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "00db6112-34c3-46a6-abeb-4f179fbbd1a9"}}}}, {"uuid": "63fba15d-7056-4866-a483-76cfd4b7b3d1", "name": "", "x": 38.61582271842178, "y": -122.43459776600604, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cee79fe8-f140-4be9-aa6b-d56e37fb6857", "name": "p1rlv12222", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "63fba15d-7056-4866-a483-76cfd4b7b3d1"}}}}, {"uuid": "ef651d7a-fc6b-426f-b064-fc2e60a74988", "name": "", "x": 38.61514654148174, "y": -122.43395232342587, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e8e1f797-9417-447c-8a08-cf00a462ef14", "name": "p1rlv12225", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef651d7a-fc6b-426f-b064-fc2e60a74988"}}}}, {"uuid": "7c88c271-f3f6-45d4-9919-0e24699d4215", "name": "", "x": 38.586418831345604, "y": -122.50394128809963, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d654945d-b71d-4943-86a2-5830fca200c9", "name": "p1rdt6038lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7c88c271-f3f6-45d4-9919-0e24699d4215"}}}}, {"uuid": "ab853430-e034-4565-b98b-2589bd82df86", "name": "", "x": 38.58644635289331, "y": -122.50405591684549, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b42c2471-9114-4042-980e-dd226ad024a3", "name": "p1rlv12538", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ab853430-e034-4565-b98b-2589bd82df86"}}}}, {"uuid": "3d46fae0-0a33-4fd5-ac7e-6282cd5526e1", "name": "", "x": 38.583699762043224, "y": -122.50722384389097, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e5ae7bbf-f53e-4ae2-8145-bf56ce935094", "name": "p1rdt6043lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3d46fae0-0a33-4fd5-ac7e-6282cd5526e1"}}}}, {"uuid": "8037a8ee-3906-490a-9533-13016db8fd6c", "name": "", "x": 38.583590695705574, "y": -122.50712562826531, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4c42d772-e2a8-45d4-9cf2-2edd7a567b35", "name": "p1rlv12552", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8037a8ee-3906-490a-9533-13016db8fd6c"}}}}, {"uuid": "2aa9b7fa-506a-4f8c-8242-7ecbcfa25a2d", "name": "", "x": 38.58378667878022, "y": -122.50658466351123, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b3e53a11-6c13-4d27-89f2-2abbd28f69ac", "name": "p1rdm12875", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2aa9b7fa-506a-4f8c-8242-7ecbcfa25a2d"}}}}, {"uuid": "65da88d8-f338-4c87-9275-83b61c7bfc38", "name": "", "x": 38.58345266624825, "y": -122.50644917302039, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a29aec49-62a4-41ec-a67c-a84470a23f7b", "name": "p1rlv12553", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65da88d8-f338-4c87-9275-83b61c7bfc38"}}}}, {"uuid": "ea0e1728-da0c-415a-b2d8-63292335ef42", "name": "", "x": 38.58361036220623, "y": -122.50751586004849, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b748c697-b624-43f0-b375-5024d8cff92b", "name": "p1rdm12876", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea0e1728-da0c-415a-b2d8-63292335ef42"}}}}, {"uuid": "279d7791-7332-446f-84ff-965c7c9af534", "name": "", "x": 38.58369185365201, "y": -122.50760715446228, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75a47101-b6df-473e-9c7b-96e076c17931", "name": "p1rlv12559", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "279d7791-7332-446f-84ff-965c7c9af534"}}}}, {"uuid": "533b497d-f2b9-4c9a-b5d2-76e4e9c93a3c", "name": "", "x": 38.58357450876428, "y": -122.50756203032971, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3082eb6b-1a9f-4b6e-930e-f58173fe02ac", "name": "p1rdm12877", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "533b497d-f2b9-4c9a-b5d2-76e4e9c93a3c"}}}}, {"uuid": "efefb47a-9073-4b89-a2b8-7be8b197bb61", "name": "", "x": 38.58361995350426, "y": -122.5076535708703, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8b0417d3-820d-4daa-aec5-3dcf34e40e00", "name": "p1rlv12562", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "efefb47a-9073-4b89-a2b8-7be8b197bb61"}}}}, {"uuid": "6989f2f9-0ff1-40bd-a0b5-15527010b9ad", "name": "", "x": 38.583744918789954, "y": -122.50735404765867, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b2e2d1a7-039c-4b29-a061-b814ac675e3b", "name": "p1rdt6046lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6989f2f9-0ff1-40bd-a0b5-15527010b9ad"}}}}, {"uuid": "efcefbeb-719b-4ce3-b9ad-5d962103723a", "name": "", "x": 38.5839884657107, "y": -122.50742142633933, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4fe4d6ae-cca5-476c-981a-a1dcd27b1e84", "name": "p1rlv12557", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "efcefbeb-719b-4ce3-b9ad-5d962103723a"}}}}, {"uuid": "313e68dc-5043-4c00-aeb7-0a6788fddbe1", "name": "", "x": 38.5843554229652, "y": -122.50614844559887, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "21e75ccd-7e21-4f0d-890c-81aa6b33b109", "name": "p1rdt6047lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "313e68dc-5043-4c00-aeb7-0a6788fddbe1"}}}}, {"uuid": "a3824258-2643-48e3-8a13-8ebabaac90ac", "name": "", "x": 38.584325151037234, "y": -122.50605283115296, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0a427f20-861a-4616-9443-265beaeccca3", "name": "p1rlv12558", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a3824258-2643-48e3-8a13-8ebabaac90ac"}}}}, {"uuid": "1b8d5c33-b1ec-42d0-a6da-c5736badbefd", "name": "", "x": 38.605026243337974, "y": -122.47603639568145, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "01be483b-09f4-450e-a39d-78692c40ee8b", "name": "p1rdt6208lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1b8d5c33-b1ec-42d0-a6da-c5736badbefd"}}}}, {"uuid": "39d40bfc-7bc0-40d3-8121-d070af0c9f8b", "name": "", "x": 38.60501243846355, "y": -122.47608741299466, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "019e419c-9f88-455a-bf48-b89531ed9e51", "name": "p1rlv12936", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "39d40bfc-7bc0-40d3-8121-d070af0c9f8b"}}}}, {"uuid": "384d4ef5-af8c-43a0-a01a-b48e88a27593", "name": "", "x": 38.60004659977005, "y": -122.48124037604637, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "73f78740-2ec5-4ad8-b7fb-40f4a72b730e", "name": "p1rdt6221lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "384d4ef5-af8c-43a0-a01a-b48e88a27593"}}}}, {"uuid": "e8e66f12-8da3-41bd-b6fa-3dcac2ae471f", "name": "", "x": 38.60002062477275, "y": -122.48119777346218, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8418804f-aad5-49df-9916-f427da5089c1", "name": "p1rlv12959", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e8e66f12-8da3-41bd-b6fa-3dcac2ae471f"}}}}, {"uuid": "5aef84c3-b54b-424d-8ebe-45dc09d4dd79", "name": "", "x": 38.604436381862065, "y": -122.47563389239149, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3154eee7-a1ba-4b9d-9e91-bab55529d358", "name": "p1rdt6226lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5aef84c3-b54b-424d-8ebe-45dc09d4dd79"}}}}, {"uuid": "a4d56043-79b9-4411-b7b6-c7e551d90dfa", "name": "", "x": 38.604742034520584, "y": -122.47609857017211, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be845651-8e1c-4b6d-8633-fcbdfb1fd5d4", "name": "p1rlv12971", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a4d56043-79b9-4411-b7b6-c7e551d90dfa"}}}}, {"uuid": "2b9957d6-67cd-47ad-8f4b-d0ec588d795e", "name": "", "x": 38.60407996866283, "y": -122.47516164611108, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "646058a3-cda7-4723-bd0f-05d305fe7c11", "name": "p1rlv20185", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2b9957d6-67cd-47ad-8f4b-d0ec588d795e"}}}}, {"uuid": "459fe982-19fb-4fc7-937f-3429aa535d9f", "name": "", "x": 38.61627084774632, "y": -122.45497361088964, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "72ce0706-6b32-4b4b-9bf3-fd1f5a6af5ca", "name": "p1rdt6268lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "459fe982-19fb-4fc7-937f-3429aa535d9f"}}}}, {"uuid": "9667d696-5ea7-451e-9dd5-318e13202abf", "name": "", "x": 38.616595375163186, "y": -122.45499188425644, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3072c6c-3a40-4e49-bd00-febc8268b135", "name": "p1rlv13043", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9667d696-5ea7-451e-9dd5-318e13202abf"}}}}, {"uuid": "5b18d64b-c7b4-4e7f-b793-a467aa5f1eb0", "name": "", "x": 38.61557658935668, "y": -122.45489621541526, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4209bdad-276f-4e07-93e0-78b162ce95cf", "name": "p1rlv13047", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5b18d64b-c7b4-4e7f-b793-a467aa5f1eb0"}}}}, {"uuid": "f0178992-d931-4425-b1f8-6cf772629d45", "name": "", "x": 38.61659769116569, "y": -122.45488097254983, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "21c6ea4f-ec9d-424e-8743-7175408f9e2c", "name": "p1rlv13054", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f0178992-d931-4425-b1f8-6cf772629d45"}}}}, {"uuid": "cb47612f-823d-4fd9-b8da-f9f951b87220", "name": "", "x": 38.615484628332915, "y": -122.45948878298002, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "79c91fa8-15ad-4e8d-96bd-2cad395dd280", "name": "p1rdt6269lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb47612f-823d-4fd9-b8da-f9f951b87220"}}}}, {"uuid": "5f7b1184-1a50-4c3b-abc1-6f10d6b0e56b", "name": "", "x": 38.61545864547562, "y": -122.45944617926628, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fa31c772-8460-4624-a123-64b87ca8d332", "name": "p1rlv13044", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5f7b1184-1a50-4c3b-abc1-6f10d6b0e56b"}}}}, {"uuid": "e5f6f0cd-c468-47f3-8889-ba4631b16481", "name": "", "x": 38.61293890712679, "y": -122.45937135963467, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5adb2083-3d46-48a7-8996-37c0781b0215", "name": "p1rdt6270lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e5f6f0cd-c468-47f3-8889-ba4631b16481"}}}}, {"uuid": "d0437a27-08ad-41e0-a4a5-0be10eada9ba", "name": "", "x": 38.61312062731428, "y": -122.45970448051091, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6070414d-09e7-48a7-aec0-c105cc0f1a93", "name": "p1rlv13045", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d0437a27-08ad-41e0-a4a5-0be10eada9ba"}}}}, {"uuid": "a6648dc2-4180-476b-84b9-d71723671f17", "name": "", "x": 38.61305606107207, "y": -122.459383355912, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5edc15fb-49d5-4052-8fad-4979578f6ed1", "name": "p1rlv13046", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a6648dc2-4180-476b-84b9-d71723671f17"}}}}, {"uuid": "6e31ef12-0466-48cc-9ff0-19a2da1c50f8", "name": "", "x": 38.612568269488285, "y": -122.45913432583363, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "86d59550-d7c8-47e1-a6bc-14b2d50de58c", "name": "p1rlv13052", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6e31ef12-0466-48cc-9ff0-19a2da1c50f8"}}}}, {"uuid": "a27adeee-5e06-4c0b-935d-a908465d154f", "name": "", "x": 38.61201252826336, "y": -122.45742705644044, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1335e64c-9f37-4e73-a37f-8f76737cabff", "name": "p1rdt6271lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a27adeee-5e06-4c0b-935d-a908465d154f"}}}}, {"uuid": "e19ce3da-55ab-4c6b-ad4c-5f038c6b2ffb", "name": "", "x": 38.6124662872462, "y": -122.45657372759852, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "569078be-37c2-4c05-8455-91945eb7fdb9", "name": "p1rlv13048", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e19ce3da-55ab-4c6b-ad4c-5f038c6b2ffb"}}}}, {"uuid": "f6a8b3a9-1c2a-45e7-a53b-b1002f1822ad", "name": "", "x": 38.61056246852402, "y": -122.45546646876214, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "04422e0a-1952-422d-a201-5fafef1875db", "name": "p1rdt6272lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f6a8b3a9-1c2a-45e7-a53b-b1002f1822ad"}}}}, {"uuid": "d0a8d9b3-58c2-4f85-9b1b-a839988d3996", "name": "", "x": 38.61046043697304, "y": -122.45545178295872, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3ed85192-4c5a-4c15-ba21-1ba883b03ddd", "name": "p1rlv13049", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d0a8d9b3-58c2-4f85-9b1b-a839988d3996"}}}}, {"uuid": "170ec7fe-fcf7-4acf-b429-559cbeaf6976", "name": "", "x": 38.61065269092905, "y": -122.4554887580758, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e058437-0138-4305-a33e-d8fa61aed8cc", "name": "p1rlv13053", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "170ec7fe-fcf7-4acf-b429-559cbeaf6976"}}}}, {"uuid": "bc8f8b98-5280-45f9-8ac4-52ad1f005535", "name": "", "x": 38.61008611720184, "y": -122.45635048585197, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2b6739c0-1b15-42c1-9fdd-4d7f604a03ce", "name": "p1rdm13376", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bc8f8b98-5280-45f9-8ac4-52ad1f005535"}}}}, {"uuid": "68405c44-dbe2-4a6b-9268-accf72aead68", "name": "", "x": 38.61016439157834, "y": -122.45574115998643, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e9a855b0-538e-4fab-91f1-93b4ece09409", "name": "p1rlv13051", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "68405c44-dbe2-4a6b-9268-accf72aead68"}}}}, {"uuid": "e2efd60d-46ec-4832-9b23-6f31a690ecb5", "name": "", "x": 38.61026024108263, "y": -122.45636462882881, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b1db8c80-e791-4c31-a6f2-713aa665bf41", "name": "p1rdt6274lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e2efd60d-46ec-4832-9b23-6f31a690ecb5"}}}}, {"uuid": "cbd8342d-f215-4a5b-9bb6-d8f6f08670f7", "name": "", "x": 38.610392670089375, "y": -122.45638262926296, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e395985-4c66-49c9-9252-94d8078b8e8e", "name": "p1rdm13377", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cbd8342d-f215-4a5b-9bb6-d8f6f08670f7"}}}}, {"uuid": "4e8da740-8364-40d4-81e3-115c6cd3df80", "name": "", "x": 38.610432528075556, "y": -122.45587299013495, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16584dfd-537d-4b0d-a651-c73d0beabc6d", "name": "p1rlv13056", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4e8da740-8364-40d4-81e3-115c6cd3df80"}}}}, {"uuid": "fbf44c78-ce05-4b63-960e-76194f6ae49f", "name": "", "x": 38.610983387394924, "y": -122.45878265444647, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ba567584-fbee-44eb-b3f1-da24a0ce66a0", "name": "p1rdt6275lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fbf44c78-ce05-4b63-960e-76194f6ae49f"}}}}, {"uuid": "5111021a-6b72-40f1-b986-267d9c612a93", "name": "", "x": 38.61089111139205, "y": -122.45892869017909, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "387df3d3-5f03-47f4-8b16-bea8815e63d1", "name": "p1rlv13055", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5111021a-6b72-40f1-b986-267d9c612a93"}}}}, {"uuid": "b1bffdbe-f800-471c-a218-2352f3de7841", "name": "", "x": 38.611024903573316, "y": -122.45862905688004, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c83997dc-872f-494f-8c8a-7266c854fc48", "name": "p1rlv13058", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b1bffdbe-f800-471c-a218-2352f3de7841"}}}}, {"uuid": "8daf5a93-0aba-4efe-b6f8-87702fbd5e96", "name": "", "x": 38.61593370015664, "y": -122.45611332456588, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2f20ace2-5ec8-4451-b7e7-66f46c2c487b", "name": "p1rdt6276lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8daf5a93-0aba-4efe-b6f8-87702fbd5e96"}}}}, {"uuid": "cb93529c-6913-4fbe-a725-7e4dee686cdb", "name": "", "x": 38.616214343979955, "y": -122.45638463812467, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2c63d163-75bd-4d91-bcfa-229a2e331b1f", "name": "p1rlv13057", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb93529c-6913-4fbe-a725-7e4dee686cdb"}}}}, {"uuid": "ac857cdd-f51e-4fa1-9097-01222c65d188", "name": "", "x": 38.61560758048402, "y": -122.45574597720416, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8d2fa164-4c03-4bcd-a386-749ccd4e9001", "name": "p1rlv13062", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ac857cdd-f51e-4fa1-9097-01222c65d188"}}}}, {"uuid": "59b0c5c4-2dde-4be1-92d4-fc14c7f28bfc", "name": "", "x": 38.61608078908832, "y": -122.45806664881565, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e582b04d-a8d8-4ee9-8576-1e5941623c0b", "name": "p1rdt6277lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59b0c5c4-2dde-4be1-92d4-fc14c7f28bfc"}}}}, {"uuid": "ea6ecbce-6597-489c-806f-0b38415136ee", "name": "", "x": 38.616096280398985, "y": -122.45813147961287, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a1779b5b-1a6c-4511-9d4b-88026b430173", "name": "p1rlv13059", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea6ecbce-6597-489c-806f-0b38415136ee"}}}}, {"uuid": "b3dc1c19-d603-4d73-8550-c2b4745ed0ab", "name": "", "x": 38.616472312390336, "y": -122.45760251208678, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2b37eabc-787a-491f-bc4f-956f43a862ff", "name": "p1rdt6278lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b3dc1c19-d603-4d73-8550-c2b4745ed0ab"}}}}, {"uuid": "88ff6605-6274-48d5-a8df-b913f605e687", "name": "", "x": 38.61659895813833, "y": -122.45770269368248, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8767a040-da31-48d9-9473-0941856bcedc", "name": "p1rlv13060", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "88ff6605-6274-48d5-a8df-b913f605e687"}}}}, {"uuid": "d35605b8-f529-4dd5-ae8a-7cd432ad68bb", "name": "", "x": 38.635969271978226, "y": -122.41468609161443, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3a38eb6d-a625-42a1-95f6-bbf078d1447a", "name": "p1rdt6345lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d35605b8-f529-4dd5-ae8a-7cd432ad68bb"}}}}, {"uuid": "4016c322-b0a6-4180-bc76-3154deee1dad", "name": "", "x": 38.63598364556035, "y": -122.41473687445114, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c29c3206-b71d-41d1-8ad7-a693c8c25d4d", "name": "p1rlv13185", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4016c322-b0a6-4180-bc76-3154deee1dad"}}}}, {"uuid": "6cb57e62-5516-46bd-a1bd-16b0ff15d7fd", "name": "", "x": 38.638887372960305, "y": -122.42670366638174, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e40008af-ff50-42bd-8897-f663c27a436f", "name": "p1rdt6347lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6cb57e62-5516-46bd-a1bd-16b0ff15d7fd"}}}}, {"uuid": "e79a71dd-ab3c-4e4f-b0da-a0a3d2960fd9", "name": "", "x": 38.63887629434703, "y": -122.42675582564294, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ffbd17b6-b1a2-4e55-9052-67a84419bb9d", "name": "p1rlv13187", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e79a71dd-ab3c-4e4f-b0da-a0a3d2960fd9"}}}}, {"uuid": "effbfb8c-623e-49b9-a2a9-7c2b94ad9651", "name": "", "x": 38.63741237955581, "y": -122.41088141259655, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d84ac329-f314-41be-a2ee-89bc74789a18", "name": "p1rdt6348lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "effbfb8c-623e-49b9-a2a9-7c2b94ad9651"}}}}, {"uuid": "b0eb5a62-8284-4550-a2a3-f5fe56a755e1", "name": "", "x": 38.63776633109597, "y": -122.41081354844057, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "67ffcd9f-ba90-4da7-b3b6-46310e321590", "name": "p1rlv13188", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b0eb5a62-8284-4550-a2a3-f5fe56a755e1"}}}}, {"uuid": "05557a96-5314-4ed4-b7f0-eb914262c728", "name": "", "x": 38.63725354679822, "y": -122.41099009448936, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3f6d09e9-3592-4560-8626-0d7cb71ca56a", "name": "p1rlv13191", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "05557a96-5314-4ed4-b7f0-eb914262c728"}}}}, {"uuid": "6b814f18-4e8f-4dc6-a472-a092ced2af22", "name": "", "x": 38.63720762179658, "y": -122.41081812238316, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2e3e10c6-6ce2-4efa-be50-80e8b9bffe29", "name": "p1rlv13195", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6b814f18-4e8f-4dc6-a472-a092ced2af22"}}}}, {"uuid": "723dc179-b0d4-453a-a37d-3602709a2654", "name": "", "x": 38.63750552004759, "y": -122.4109190928234, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2cdd7c49-e758-4009-8db5-d0b5748f919c", "name": "p1rlv13201", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "723dc179-b0d4-453a-a37d-3602709a2654"}}}}, {"uuid": "855b9038-87f7-4d5d-b419-c8e7d259873c", "name": "", "x": 38.64190459200407, "y": -122.42077252919503, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fdfa0310-7dc5-4181-a64e-cc2522370547", "name": "p1rdt6349lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "855b9038-87f7-4d5d-b419-c8e7d259873c"}}}}, {"uuid": "a02fd54c-e29a-4c35-bbfb-ae25adf08bd4", "name": "", "x": 38.6420159229094, "y": -122.42084455001161, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "268361f6-d5ac-4002-80a6-f56f3b33599c", "name": "p1rlv13189", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a02fd54c-e29a-4c35-bbfb-ae25adf08bd4"}}}}, {"uuid": "06e6e604-e32f-43a8-a8e3-cb370f644ed3", "name": "", "x": 38.636198973427064, "y": -122.41018025968964, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0138b892-d18e-497c-9857-c4d5676deac2", "name": "p1rdt6350lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "06e6e604-e32f-43a8-a8e3-cb370f644ed3"}}}}, {"uuid": "1854b823-e587-42c6-9322-3428ce6ce9b2", "name": "", "x": 38.63617297274995, "y": -122.41013766183407, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3dbc593c-3949-4fa4-8738-d92540dbf998", "name": "p1rlv13190", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1854b823-e587-42c6-9322-3428ce6ce9b2"}}}}, {"uuid": "2166852d-80a3-428b-8d53-254aa32d4239", "name": "", "x": 38.634295860150814, "y": -122.41680227142706, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "015322ae-7712-488f-9569-33fc785e4f62", "name": "p1rdt6353lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2166852d-80a3-428b-8d53-254aa32d4239"}}}}, {"uuid": "7e881470-549e-48ee-adf6-abc91359e7f6", "name": "", "x": 38.634321357711805, "y": -122.41675918344534, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2d5ba889-d8f7-44ca-86b2-40939fa95df2", "name": "p1rlv13194", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7e881470-549e-48ee-adf6-abc91359e7f6"}}}}, {"uuid": "527d288f-2043-4812-9466-eedc4d8ab423", "name": "", "x": 38.63633728483974, "y": -122.42060300525114, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0fd10fd1-b67f-422c-b976-582e2bb4e0ec", "name": "p1rdm13558", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "527d288f-2043-4812-9466-eedc4d8ab423"}}}}, {"uuid": "1dca3f46-9489-4e6b-8c7c-ebe7d8fde286", "name": "", "x": 38.63688282698339, "y": -122.41975985681357, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "27013147-3d8f-4d75-a7a7-24457dc6d62a", "name": "p1rlv13196", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1dca3f46-9489-4e6b-8c7c-ebe7d8fde286"}}}}, {"uuid": "8cc62ace-11fa-4dd3-a1d9-b50e2ad0e7a0", "name": "", "x": 38.63646127576851, "y": -122.42073591122158, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f06a08bd-05ea-4914-b0d0-07cd0e83bfbc", "name": "p1rdt6354lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8cc62ace-11fa-4dd3-a1d9-b50e2ad0e7a0"}}}}, {"uuid": "c604b145-f503-41b1-9dc4-2f31cad75e9b", "name": "", "x": 38.63663597134643, "y": -122.42086486559913, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "786efaf4-c281-4def-9a4e-2ffbf37e08be", "name": "p1rdm13559", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c604b145-f503-41b1-9dc4-2f31cad75e9b"}}}}, {"uuid": "a95d2d49-eb75-4e81-a97c-4fd013ac2e53", "name": "", "x": 38.63697733189416, "y": -122.42007329323263, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fed30a3f-12a5-4545-b5d5-5c13a131a256", "name": "p1rlv13200", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a95d2d49-eb75-4e81-a97c-4fd013ac2e53"}}}}, {"uuid": "a8acb079-e050-43db-b97d-4a7c0aed2fdf", "name": "", "x": 38.64208811872309, "y": -122.42143750947257, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f1d14a79-4d18-43fe-8790-57ea9adf83a8", "name": "p1rdt6355lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8acb079-e050-43db-b97d-4a7c0aed2fdf"}}}}, {"uuid": "ecb37bad-3593-475c-827e-ec4e7777c96f", "name": "", "x": 38.64203661805849, "y": -122.42138444352005, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7b077d0f-74ec-4a04-8eb8-cf02ad16077d", "name": "p1rlv13197", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ecb37bad-3593-475c-827e-ec4e7777c96f"}}}}, {"uuid": "76c93f4d-c02a-44ff-b4b5-6f417c2b54a4", "name": "", "x": 38.637121227961, "y": -122.41980119772418, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "548724aa-110a-428f-b71a-acdf0051dc39", "name": "p1rdt6356lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "76c93f4d-c02a-44ff-b4b5-6f417c2b54a4"}}}}, {"uuid": "a6b8ea32-a985-4859-ab59-f6d7b0d0da63", "name": "", "x": 38.6370952307597, "y": -122.41975859580664, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ad7545fb-8a41-4ed7-a178-e90f19bfa9d5", "name": "p1rlv13199", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a6b8ea32-a985-4859-ab59-f6d7b0d0da63"}}}}, {"uuid": "ddfdec26-8ee3-49e0-9a72-cb7236e92342", "name": "", "x": 38.625625701122225, "y": -122.46597233146389, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e36cfaaa-3996-4cc6-aa4f-170f20c5d1e0", "name": "p1rdt6409lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ddfdec26-8ee3-49e0-9a72-cb7236e92342"}}}}, {"uuid": "b2a436d9-b0f8-48e2-aeb6-3e0d1f57befc", "name": "", "x": 38.625599720610666, "y": -122.46592971942587, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "473b080b-1412-40dc-a452-09d43a462098", "name": "p1rlv13316", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b2a436d9-b0f8-48e2-aeb6-3e0d1f57befc"}}}}, {"uuid": "0b946f90-2e39-4fd3-b0ba-8544c409d55c", "name": "", "x": 38.578857638178405, "y": -122.51077785799649, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7", "name": "p1rdt6498lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0b946f90-2e39-4fd3-b0ba-8544c409d55c"}}}}, {"uuid": "1d821ba2-72a7-4d64-b2d1-a334142c0759", "name": "", "x": 38.57893830123369, "y": -122.5108886242969, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "353889fb-da44-4cf8-ae0e-d20541f36d7e", "name": "p1rlv13597", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d821ba2-72a7-4d64-b2d1-a334142c0759"}}}}, {"uuid": "467c88e4-d134-4fa8-9e81-73a5a3be69ab", "name": "", "x": 38.57885671632947, "y": -122.51077437155158, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6015a810-79da-480f-b1a1-fd6a4abdba37", "name": "p1rlv13631", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "467c88e4-d134-4fa8-9e81-73a5a3be69ab"}}}}, {"uuid": "d9c52a80-2697-4d5e-914c-a915bfd7285f", "name": "", "x": 38.579117623107756, "y": -122.51066927591476, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f92273c9-90b8-4819-b036-9d69afb5aed6", "name": "p1rlv13696", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d9c52a80-2697-4d5e-914c-a915bfd7285f"}}}}, {"uuid": "b7b04bac-1b23-4b18-bc24-f9ee42054770", "name": "", "x": 38.57882896139523, "y": -122.51060235083729, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1fe3c958-296f-4b51-8b2b-74bb34ddb5a6", "name": "p1rlv13702", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b7b04bac-1b23-4b18-bc24-f9ee42054770"}}}}, {"uuid": "9aaf3362-751e-4e7d-ab80-e0243d0b72f8", "name": "", "x": 38.578814411150496, "y": -122.51075566702022, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c9efacf5-5b96-4670-b6f1-dc398485cde9", "name": "p1rlv13703", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9aaf3362-751e-4e7d-ab80-e0243d0b72f8"}}}}, {"uuid": "1d16ca37-4d9e-4caa-adb7-d56ca9da816a", "name": "", "x": 38.57878534253772, "y": -122.51094706458596, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "457c6c9d-5020-4cf3-9c1e-c36012a619d2", "name": "p1rlv13724", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d16ca37-4d9e-4caa-adb7-d56ca9da816a"}}}}, {"uuid": "8390b3b1-225b-4c6a-896a-3fb330512d9c", "name": "", "x": 38.58016810697636, "y": -122.51189059526916, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ce39f1f5-b784-4919-9d3d-f6149f39595e", "name": "p1rdm13996", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8390b3b1-225b-4c6a-896a-3fb330512d9c"}}}}, {"uuid": "7d953cf8-edae-40e4-91a0-6f7cb240f34b", "name": "", "x": 38.5798974214499, "y": -122.5118120619195, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "59953c2f-244e-4bb8-ab24-b28d82b195e1", "name": "p1rlv13598", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7d953cf8-edae-40e4-91a0-6f7cb240f34b"}}}}, {"uuid": "93963b59-7c3d-4dd6-ac3e-0ad59a026255", "name": "", "x": 38.57980967492142, "y": -122.51170181808382, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aeea20e0-9908-4f28-aa5d-068244e3861b", "name": "p1rlv13626", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "93963b59-7c3d-4dd6-ac3e-0ad59a026255"}}}}, {"uuid": "1ad6b39f-4277-41f1-9a59-2045f78b2e42", "name": "", "x": 38.57989689465763, "y": -122.51168577702153, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cc33013a-6a90-46a7-9127-f32288111c14", "name": "p1rlv13635", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1ad6b39f-4277-41f1-9a59-2045f78b2e42"}}}}, {"uuid": "5eeeb5e6-f8c4-4529-a6ba-bfc863eb4f1e", "name": "", "x": 38.579743504522455, "y": -122.51164089263591, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7b3e7495-7732-42ce-8d53-a5f1b7383ce4", "name": "p1rlv20504", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5eeeb5e6-f8c4-4529-a6ba-bfc863eb4f1e"}}}}, {"uuid": "c3a02a5e-5c58-4beb-a733-0ec716c360ff", "name": "", "x": 38.5802287989983, "y": -122.5117616084684, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bb05d831-1556-4f56-8065-d9d16657caa3", "name": "p1rdt6499lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c3a02a5e-5c58-4beb-a733-0ec716c360ff"}}}}, {"uuid": "a99ef52b-4365-4bea-9c0d-269b26323d76", "name": "", "x": 38.58030555227583, "y": -122.51158054354175, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f85240e6-bbbe-4b90-8419-a00a3ca9613f", "name": "p1rdm13999", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a99ef52b-4365-4bea-9c0d-269b26323d76"}}}}, {"uuid": "3faf2268-1c3c-4bf5-bd88-7c9001bd6c12", "name": "", "x": 38.57988706857757, "y": -122.51149067050049, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3839c291-3f45-46c3-973f-6a9615fcf81b", "name": "p1rlv13698", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3faf2268-1c3c-4bf5-bd88-7c9001bd6c12"}}}}, {"uuid": "149c7dea-71cc-4482-83fc-8194d3d50a88", "name": "", "x": 38.58035293960693, "y": -122.51140410649425, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ea740eb8-42c6-4417-97d6-7c73f1fc2bc8", "name": "p1rdm14000", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "149c7dea-71cc-4482-83fc-8194d3d50a88"}}}}, {"uuid": "108611d9-9d63-47a3-aae9-ef2cdacf6787", "name": "", "x": 38.580220356921046, "y": -122.5114539704366, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "642597e6-fe60-442f-b356-2be6f21677b2", "name": "p1rlv13726", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "108611d9-9d63-47a3-aae9-ef2cdacf6787"}}}}, {"uuid": "17774d75-030e-4f6b-b9fc-a5ea4e90bb77", "name": "", "x": 38.58083948102145, "y": -122.5097420033343, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a20a4242-8a76-49f3-9bf5-3d7aaf751cdc", "name": "p1rdt6500lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "17774d75-030e-4f6b-b9fc-a5ea4e90bb77"}}}}, {"uuid": "fca68e74-8079-476d-8e08-9403ecc91752", "name": "", "x": 38.58075318348773, "y": -122.50956749241811, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "216537dd-ea7b-461c-b821-99491c41b7f0", "name": "p1rlv13613", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fca68e74-8079-476d-8e08-9403ecc91752"}}}}, {"uuid": "946b4384-4111-4b9d-baa0-3d02c5634209", "name": "", "x": 38.58094565510626, "y": -122.50948667802179, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "83aa4266-e486-4e00-a09b-7bcdc613a9b5", "name": "p1rdm14004", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "946b4384-4111-4b9d-baa0-3d02c5634209"}}}}, {"uuid": "98f2af76-03e7-4ca3-8482-85d5bb432b8c", "name": "", "x": 38.580815639747385, "y": -122.50941781578797, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f823a90c-effd-489c-9e0a-c110ccb7b9e8", "name": "p1rlv13618", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "98f2af76-03e7-4ca3-8482-85d5bb432b8c"}}}}, {"uuid": "273b3d0e-7740-4807-828e-a1e37aa9d0e9", "name": "", "x": 38.58094199565767, "y": -122.50946287997223, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ff282b99-30bb-4c1d-acb9-02fafe241577", "name": "p1rdm14007", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "273b3d0e-7740-4807-828e-a1e37aa9d0e9"}}}}, {"uuid": "43d3fb88-4440-485a-a7d4-1cfa651312fb", "name": "", "x": 38.580561868772826, "y": -122.50907511585717, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1c61a243-7736-46a0-a950-7cc811381158", "name": "p1rlv13653", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "43d3fb88-4440-485a-a7d4-1cfa651312fb"}}}}, {"uuid": "57b109ad-77d4-4e35-8c6a-2d1b67884755", "name": "", "x": 38.58103524253283, "y": -122.50935977822509, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3c0ae3b1-ac0d-43c9-9a1e-c73bd10e3ad8", "name": "p1rdm14002", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "57b109ad-77d4-4e35-8c6a-2d1b67884755"}}}}, {"uuid": "974a1a48-d33c-48aa-aeb5-230ce3105a1c", "name": "", "x": 38.58069699573112, "y": -122.50906271510544, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d2a60818-4310-4100-9aa8-35ef37aa5f40", "name": "p1rlv13599", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "974a1a48-d33c-48aa-aeb5-230ce3105a1c"}}}}, {"uuid": "fabd8bb6-7edf-42be-8e6b-5663ec1f9863", "name": "", "x": 38.58115055848325, "y": -122.50921129101727, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d576dffc-af75-488e-8c51-19aa726f0505", "name": "p1rdm14005", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fabd8bb6-7edf-42be-8e6b-5663ec1f9863"}}}}, {"uuid": "631cb3f9-1cef-4bac-96dc-ab0058dd06c9", "name": "", "x": 38.58066046743406, "y": -122.50894815487301, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "62a29ac5-7227-43b2-b602-b1189cc93839", "name": "p1rlv13648", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "631cb3f9-1cef-4bac-96dc-ab0058dd06c9"}}}}, {"uuid": "e50ab3f8-8db4-47ab-851d-95ec1d4566e7", "name": "", "x": 38.58075404919642, "y": -122.50977414282289, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7e5abf33-75a2-446f-9c6c-1f3384b78c24", "name": "p1rdm14008", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e50ab3f8-8db4-47ab-851d-95ec1d4566e7"}}}}, {"uuid": "45f7226f-8189-4fdd-986c-9f3171a508b2", "name": "", "x": 38.58080831157611, "y": -122.50981969761952, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4671f981-e26e-4f26-9698-7f9068ce6dec", "name": "p1rlv13687", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "45f7226f-8189-4fdd-986c-9f3171a508b2"}}}}, {"uuid": "4690aac7-835d-4f30-ae06-41a51aaf2b24", "name": "", "x": 38.580709327387154, "y": -122.50985481311328, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "592b8095-ba99-4993-a445-9af51fa89f57", "name": "p1rdm14009", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4690aac7-835d-4f30-ae06-41a51aaf2b24"}}}}, {"uuid": "c77d28e1-b011-4ecc-a915-17583b1adf98", "name": "", "x": 38.580745614457776, "y": -122.50991197100555, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "44aa3f37-e0db-4050-b47f-ac14b7fa6534", "name": "p1rlv13719", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c77d28e1-b011-4ecc-a915-17583b1adf98"}}}}, {"uuid": "810ea90d-e32b-4403-a753-626d87d2255b", "name": "", "x": 38.58065559384605, "y": -122.50993554454202, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33445b16-68bf-4606-8ac5-def4763fb95d", "name": "p1rdm14006", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "810ea90d-e32b-4403-a753-626d87d2255b"}}}}, {"uuid": "8cb81b56-81c0-4541-bf0e-8d99301e93e7", "name": "", "x": 38.58069192894027, "y": -122.51000418300181, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3310c14a-d1ee-4d0c-8428-d002703c61d5", "name": "p1rlv13652", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8cb81b56-81c0-4541-bf0e-8d99301e93e7"}}}}, {"uuid": "d5eb11ec-20a7-43a6-bcbe-8e80506573b5", "name": "", "x": 38.580115053283016, "y": -122.51211138251598, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923", "name": "p1rdt6501lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d5eb11ec-20a7-43a6-bcbe-8e80506573b5"}}}}, {"uuid": "e0c5a120-ac0a-43a9-80c0-9d910c4b0d14", "name": "", "x": 38.57996098198724, "y": -122.5119264394613, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "59ab6d81-a91c-4350-8f94-abe02e3e1555", "name": "p1rlv13600", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e0c5a120-ac0a-43a9-80c0-9d910c4b0d14"}}}}, {"uuid": "c9ff9645-8f59-4b3a-b2b6-f8365fc0a052", "name": "", "x": 38.58025012153835, "y": -122.51210817586814, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "29838633-5c95-4b73-8227-cfa7f4aedc32", "name": "p1rlv13606", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c9ff9645-8f59-4b3a-b2b6-f8365fc0a052"}}}}, {"uuid": "b28ac41e-68ec-478f-8f63-b7474b7cb521", "name": "", "x": 38.58018699193046, "y": -122.51209712213534, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a5e8caf4-4d81-4bbd-98df-6622c5ad0563", "name": "p1rlv13608", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b28ac41e-68ec-478f-8f63-b7474b7cb521"}}}}, {"uuid": "a75547f7-63ae-4c46-88ef-c390878cd28c", "name": "", "x": 38.580430450820984, "y": -122.5121299176103, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f693a1d2-5499-4810-9458-f205eda265fa", "name": "p1rlv13619", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a75547f7-63ae-4c46-88ef-c390878cd28c"}}}}, {"uuid": "36b4f113-3755-49cf-8d87-c2a79648b0d1", "name": "", "x": 38.58039473905232, "y": -122.51221052513978, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4540b2cb-ee21-4515-a7ca-fbca371f060d", "name": "p1rlv13622", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "36b4f113-3755-49cf-8d87-c2a79648b0d1"}}}}, {"uuid": "b1b116f3-0151-42b2-a8aa-ac02307e8906", "name": "", "x": 38.57999120125346, "y": -122.51201057019674, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "30c470ac-39d1-4379-9ae7-790d912bce2c", "name": "p1rlv13637", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b1b116f3-0151-42b2-a8aa-ac02307e8906"}}}}, {"uuid": "0870751c-5e1a-47c1-ab38-434e9da36a6c", "name": "", "x": 38.580262816627275, "y": -122.51171636414, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0b7d4c6f-98b5-4cec-b8a4-9311b5fc92bd", "name": "p1rdm14016", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0870751c-5e1a-47c1-ab38-434e9da36a6c"}}}}, {"uuid": "1221665c-1324-49ea-93f7-2780a566c268", "name": "", "x": 38.58050168270344, "y": -122.5119227801456, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "de45dc59-3e0a-4b33-8cf4-d5213b0140c1", "name": "p1rlv13683", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1221665c-1324-49ea-93f7-2780a566c268"}}}}, {"uuid": "16be71f9-5715-4ab6-8469-27d24af8c118", "name": "", "x": 38.58090324022768, "y": -122.51898480487121, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7682e9f7-1272-4781-b128-34c7329afe49", "name": "p1rdt6502lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "16be71f9-5715-4ab6-8469-27d24af8c118"}}}}, {"uuid": "a8cffd85-3289-411b-aba3-fe19b3957850", "name": "", "x": 38.5809550747074, "y": -122.51912974155378, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "91953a27-bbc7-494a-bec2-a12b4c0f6af6", "name": "p1rlv13601", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8cffd85-3289-411b-aba3-fe19b3957850"}}}}, {"uuid": "d1656f14-981b-475f-950b-06cfa738b307", "name": "", "x": 38.580818625476454, "y": -122.51882066658119, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "987b05d5-9bb9-434d-98b3-623ee5014870", "name": "p1rlv13634", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1656f14-981b-475f-950b-06cfa738b307"}}}}, {"uuid": "576e3987-1203-4abc-b2aa-d321607a4c09", "name": "", "x": 38.579472359669175, "y": -122.51077416509521, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "387e7785-8d40-4ddd-8c2b-14a83d4e7401", "name": "p1rdt6505lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "576e3987-1203-4abc-b2aa-d321607a4c09"}}}}, {"uuid": "117edca2-b846-4d13-9e09-6fbfb439c0a0", "name": "", "x": 38.579542563399, "y": -122.5109993333898, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c9b83bdf-b564-4997-bfc7-1be2f2e58199", "name": "p1rlv13604", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "117edca2-b846-4d13-9e09-6fbfb439c0a0"}}}}, {"uuid": "ee47ad29-c529-4e7b-a7dd-b2020a1a2885", "name": "", "x": 38.579306628363845, "y": -122.51061059015836, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c39dc6f1-08b5-4bc1-a6ae-be0076af56aa", "name": "p1rlv13605", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ee47ad29-c529-4e7b-a7dd-b2020a1a2885"}}}}, {"uuid": "0dec7af5-bd71-4eb9-b72c-26a08ebea42c", "name": "", "x": 38.57932426767413, "y": -122.51051862504016, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a7be734c-88e2-42c1-8061-f4632bd05759", "name": "p1rlv13654", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0dec7af5-bd71-4eb9-b72c-26a08ebea42c"}}}}, {"uuid": "2116346b-bc4a-4280-8b61-ba47b65fca49", "name": "", "x": 38.57968631853392, "y": -122.51089503204967, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8df1a69e-5b18-4eef-ab60-543a97257297", "name": "p1rlv13676", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2116346b-bc4a-4280-8b61-ba47b65fca49"}}}}, {"uuid": "e3d45cb8-548e-48b2-8d6b-213cd2b0dc2e", "name": "", "x": 38.579406764605274, "y": -122.51085100517132, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a822fdb0-b531-49b0-89da-b517e5ae6e3a", "name": "p1rlv13715", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e3d45cb8-548e-48b2-8d6b-213cd2b0dc2e"}}}}, {"uuid": "b166c449-a23e-4a12-b4cc-82d2661db536", "name": "", "x": 38.57531283222509, "y": -122.51744138284937, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f5844baa-5e0f-4edd-9122-fe4255adad0b", "name": "p1rdt6507lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b166c449-a23e-4a12-b4cc-82d2661db536"}}}}, {"uuid": "5eb22c70-3464-4dba-a0ef-ad656df3001f", "name": "", "x": 38.57505206910961, "y": -122.5168960568265, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "17d92377-b4f1-4194-89cd-130bddb9b77c", "name": "p1rlv13610", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5eb22c70-3464-4dba-a0ef-ad656df3001f"}}}}, {"uuid": "09e5d099-7b4a-4e2d-b26a-9262b490061d", "name": "", "x": 38.57545948963316, "y": -122.51735253068708, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5a2f5fad-c0a9-4f62-a318-ef00c0d4f470", "name": "p1rdm14031", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "09e5d099-7b4a-4e2d-b26a-9262b490061d"}}}}, {"uuid": "143b6497-07f4-4643-9cde-7468e190cad4", "name": "", "x": 38.57508745244601, "y": -122.5167350997636, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e5ab8bce-7c02-4c7b-962e-3fb44a3ab7a9", "name": "p1rlv13712", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "143b6497-07f4-4643-9cde-7468e190cad4"}}}}, {"uuid": "90a1cfbd-701d-4453-a895-51357736c657", "name": "", "x": 38.58028384394968, "y": -122.51110778698562, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5", "name": "p1rdt6508lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "90a1cfbd-701d-4453-a895-51357736c657"}}}}, {"uuid": "86ae937a-a60c-4ae1-a7c8-387f40e1eb91", "name": "", "x": 38.58035447758333, "y": -122.51120048333938, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "630b2a63-622f-4f78-8390-77c69ba7e393", "name": "p1rlv13611", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "86ae937a-a60c-4ae1-a7c8-387f40e1eb91"}}}}, {"uuid": "56eecfee-9e33-4531-a77b-2f2f7c11b0b4", "name": "", "x": 38.58037206939203, "y": -122.51109703650175, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5868c24b-2a58-459b-8650-a6072241aca8", "name": "p1rlv13666", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "56eecfee-9e33-4531-a77b-2f2f7c11b0b4"}}}}, {"uuid": "061c6dbf-e40a-4035-a3a4-ba8cb2fe1a04", "name": "", "x": 38.57994856849807, "y": -122.51111138826255, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f777bc74-e6f3-4e80-bb72-0764964db21e", "name": "p1rlv13685", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "061c6dbf-e40a-4035-a3a4-ba8cb2fe1a04"}}}}, {"uuid": "f562c711-b88d-409b-8e2e-eb3672b70456", "name": "", "x": 38.58024590590882, "y": -122.51109789179142, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aa7a324e-d367-49a5-820a-b18e72243265", "name": "p1rlv13701", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f562c711-b88d-409b-8e2e-eb3672b70456"}}}}, {"uuid": "2d927b29-01ab-4d50-a650-33eccd1a79d9", "name": "", "x": 38.5799747881709, "y": -122.51091603723427, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "286623b3-af08-4a60-896a-1f5b85fe04a5", "name": "p1rlv13707", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2d927b29-01ab-4d50-a650-33eccd1a79d9"}}}}, {"uuid": "063db81f-f1ad-43f7-88ab-eff9687a417b", "name": "", "x": 38.58041348455226, "y": -122.51100123505434, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "572123ef-d255-42a9-9c61-95d99aaff775", "name": "p1rdm14033", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "063db81f-f1ad-43f7-88ab-eff9687a417b"}}}}, {"uuid": "61501da2-c1a2-4b94-b083-88cfce749eb4", "name": "", "x": 38.58026296994941, "y": -122.51086815956218, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c808261e-a49e-4954-bdc4-a8b63d0ee25b", "name": "p1rlv13651", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "61501da2-c1a2-4b94-b083-88cfce749eb4"}}}}, {"uuid": "4b2e985c-70d7-4dd4-a2d1-1e17ef074d29", "name": "", "x": 38.58047071823679, "y": -122.5109815591307, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9657a993-0005-4ffc-8c9f-18e80a491070", "name": "p1rlv13728", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4b2e985c-70d7-4dd4-a2d1-1e17ef074d29"}}}}, {"uuid": "b204f9a6-7874-4654-b240-9f95ec20a3a3", "name": "", "x": 38.5802039677474, "y": -122.51142297137118, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f817a28f-c650-4eb4-84c0-751fe5053c75", "name": "p1rdt6509lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b204f9a6-7874-4654-b240-9f95ec20a3a3"}}}}, {"uuid": "3d63084b-d34f-45cc-acbb-fd7c7f5a12e0", "name": "", "x": 38.58031071328429, "y": -122.51151076251458, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6eda3e97-a618-41ab-ae55-ba67f6bb0234", "name": "p1rlv13612", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3d63084b-d34f-45cc-acbb-fd7c7f5a12e0"}}}}, {"uuid": "6497e293-e1f6-435a-bce1-81d85ff0cc34", "name": "", "x": 38.58038280670725, "y": -122.51151027418985, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e47df44a-79f1-423b-a295-c9c354795895", "name": "p1rlv13628", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6497e293-e1f6-435a-bce1-81d85ff0cc34"}}}}, {"uuid": "1c58cbeb-4ec0-4ca2-ac37-c2b219acb7ac", "name": "", "x": 38.58025300210597, "y": -122.51162119713781, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b65a5fd-f38e-447a-a51a-e7a214ba6bcc", "name": "p1rdm14041", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1c58cbeb-4ec0-4ca2-ac37-c2b219acb7ac"}}}}, {"uuid": "fde75755-8187-4131-a5d4-4019004aa484", "name": "", "x": 38.580112887543876, "y": -122.51161542971188, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3bd69c55-2141-4c8e-becf-efa4bff8a63e", "name": "p1rlv13627", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fde75755-8187-4131-a5d4-4019004aa484"}}}}, {"uuid": "e4998f27-5b4d-4c16-ab05-f4dac5151539", "name": "", "x": 38.580175969292135, "y": -122.51161500252242, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "122e0772-7de6-4117-b1d3-caafbbbc8e22", "name": "p1rlv13659", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e4998f27-5b4d-4c16-ab05-f4dac5151539"}}}}, {"uuid": "b4d08695-c287-4103-a10a-c5f5e7de9242", "name": "", "x": 38.58035042352862, "y": -122.51170963762122, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3d6fd13-2f04-4f23-97a3-cdf99159174c", "name": "p1rlv13660", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b4d08695-c287-4103-a10a-c5f5e7de9242"}}}}, {"uuid": "d88a5ec5-7a6d-401d-9412-e96155fdde62", "name": "", "x": 38.58048939096295, "y": -122.51181556577525, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f9aa7e62-8974-4ef0-aa5a-bcd545245aea", "name": "p1rlv13677", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d88a5ec5-7a6d-401d-9412-e96155fdde62"}}}}, {"uuid": "75d80de5-97ee-4db0-a01b-be74d82659b4", "name": "", "x": 38.58024561739162, "y": -122.51180603102428, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1252c522-5ced-4f4c-908c-f58501ad6f92", "name": "p1rdm14040", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "75d80de5-97ee-4db0-a01b-be74d82659b4"}}}}, {"uuid": "72b5ddf0-cdde-4895-9453-c7f24c784a2d", "name": "", "x": 38.580128349144296, "y": -122.51168024007933, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a5746d1-24a6-4ae4-b5dc-cef23b56660d", "name": "p1rlv13624", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "72b5ddf0-cdde-4895-9453-c7f24c784a2d"}}}}, {"uuid": "bd429e21-2c9a-44b9-8545-365dc7b0f4b3", "name": "", "x": 38.580312054434806, "y": -122.51183221682473, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6097c903-70fc-4635-a66c-fee2243ba545", "name": "p1rlv13721", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bd429e21-2c9a-44b9-8545-365dc7b0f4b3"}}}}, {"uuid": "8afa5cca-cf73-4ba5-8115-0096b37ddc9f", "name": "", "x": 38.580296766700286, "y": -122.51131091827517, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9be8942c-8459-4c1d-a3b0-a89ee5cced4e", "name": "p1rdm14043", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8afa5cca-cf73-4ba5-8115-0096b37ddc9f"}}}}, {"uuid": "29f2bebe-42ef-47a3-a9af-271923a11423", "name": "", "x": 38.5799938666379, "y": -122.51116848511225, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2b3fe33f-fdcf-42f5-be08-8da15a4d4958", "name": "p1rlv13633", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "29f2bebe-42ef-47a3-a9af-271923a11423"}}}}, {"uuid": "c53689db-2b77-4c25-b14e-1fb5d913ade2", "name": "", "x": 38.5799041333983, "y": -122.51126093949996, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "54887ca7-ae23-42d0-a715-aed8baa38ade", "name": "p1rlv13663", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c53689db-2b77-4c25-b14e-1fb5d913ade2"}}}}, {"uuid": "9ab32b8a-c150-4705-a799-5d52c7489517", "name": "", "x": 38.580282671809215, "y": -122.5112698550077, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32bec8ad-b312-4502-a2a1-6a4c9b2dd87a", "name": "p1rlv13672", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9ab32b8a-c150-4705-a799-5d52c7489517"}}}}, {"uuid": "36454f81-98b1-4198-a09a-d38e5d78e1a2", "name": "", "x": 38.58020166258251, "y": -122.51129336562714, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60fe0a16-aa4d-4fe8-9f39-81bfa13b505f", "name": "p1rlv13686", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "36454f81-98b1-4198-a09a-d38e5d78e1a2"}}}}, {"uuid": "0a18e2cb-16df-4c1c-81b6-dbb05c76fbe1", "name": "", "x": 38.57904493503404, "y": -122.51120538916284, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5d62fe3b-7644-46d1-8a15-e86d95ae8b2a", "name": "p1rdt6510lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a18e2cb-16df-4c1c-81b6-dbb05c76fbe1"}}}}, {"uuid": "f3325332-f006-4607-a16a-4f00a69b75f0", "name": "", "x": 38.5789032137621, "y": -122.51111847447159, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3de8b994-01ba-4eae-b9cf-7fb174d32355", "name": "p1rlv13614", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f3325332-f006-4607-a16a-4f00a69b75f0"}}}}, {"uuid": "ba7db288-60ce-4c65-a595-a56e7f503a45", "name": "", "x": 38.5791652716089, "y": -122.51128890787042, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "85b910cd-def8-41d8-ad47-3c074a54ad8d", "name": "p1rlv13680", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ba7db288-60ce-4c65-a595-a56e7f503a45"}}}}, {"uuid": "82223b46-a986-42df-938c-4dbe70b435f8", "name": "", "x": 38.57913785305847, "y": -122.51119724847887, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "58e2b774-ac04-435e-9e03-573b3aa94cfb", "name": "p1rlv20467", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "82223b46-a986-42df-938c-4dbe70b435f8"}}}}, {"uuid": "50b458e0-d55c-4e4a-843a-96e5759c930a", "name": "", "x": 38.58046789565426, "y": -122.5107496740826, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5702c88a-92e4-40ce-8a51-684fe6662789", "name": "p1rdt6512lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "50b458e0-d55c-4e4a-843a-96e5759c930a"}}}}, {"uuid": "cd9c9ac2-fe35-4dc5-99b4-d2982e164998", "name": "", "x": 38.58036118662805, "y": -122.51064935740038, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "850d5b69-14cf-4a18-8cb0-4f1b3033b0aa", "name": "p1rlv13616", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cd9c9ac2-fe35-4dc5-99b4-d2982e164998"}}}}, {"uuid": "3ebbb7c2-14b8-4efd-a122-9e8fedbeb88b", "name": "", "x": 38.58035246292223, "y": -122.510718301644, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "20009de0-cbe7-4b4f-a046-425a6ae71925", "name": "p1rlv13643", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3ebbb7c2-14b8-4efd-a122-9e8fedbeb88b"}}}}, {"uuid": "4bb71e49-0e3e-4855-95cd-ac756bef5eca", "name": "", "x": 38.58049679372011, "y": -122.51075176502394, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3fe0466e-cce5-4c6c-b13f-cedd349b6944", "name": "p1rlv13646", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4bb71e49-0e3e-4855-95cd-ac756bef5eca"}}}}, {"uuid": "6c71be1f-dd4f-4c0a-9aba-36a2ddb80c23", "name": "", "x": 38.5801239858384, "y": -122.51063551633443, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3fa2041e-34c4-4f1f-a329-74969c3da75f", "name": "p1rlv13650", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c71be1f-dd4f-4c0a-9aba-36a2ddb80c23"}}}}, {"uuid": "26581ec2-f996-4c6a-944b-6969311a7b5b", "name": "", "x": 38.580207508083255, "y": -122.510535591989, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e290046b-c936-4f51-b4ef-632bf572ab7f", "name": "p1rlv13725", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "26581ec2-f996-4c6a-944b-6969311a7b5b"}}}}, {"uuid": "91b7f1e8-60ef-4282-9431-17ad4a4ed438", "name": "", "x": 38.580513953094915, "y": -122.51054499300294, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e3ed4387-9ecb-43c4-a392-e72bc5cb32b6", "name": "p1rdm14062", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "91b7f1e8-60ef-4282-9431-17ad4a4ed438"}}}}, {"uuid": "bff6a849-e000-42dd-a1ca-7d6cef0fe830", "name": "", "x": 38.580216231682456, "y": -122.51046664786318, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "70cf02cc-8f1b-48ab-b9e6-50c3e58ad9ae", "name": "p1rlv13664", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bff6a849-e000-42dd-a1ca-7d6cef0fe830"}}}}, {"uuid": "5fd72616-7318-4cb3-8643-7fa32865504e", "name": "", "x": 38.58042383633111, "y": -122.5105456046176, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60f08cde-51d3-4b51-9ab5-b61c8043950f", "name": "p1rlv13681", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5fd72616-7318-4cb3-8643-7fa32865504e"}}}}, {"uuid": "55257008-f143-4a2f-b906-8ce95b1b534f", "name": "", "x": 38.58052339680616, "y": -122.51064825672786, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fdbfe616-f51f-416a-94ce-6e676d300226", "name": "p1rlv13717", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "55257008-f143-4a2f-b906-8ce95b1b534f"}}}}, {"uuid": "23176e93-7407-464d-bc9a-52c55cf5818d", "name": "", "x": 38.5805590114763, "y": -122.5105446871946, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0fe37b51-0258-4812-9d96-3cc28c4bd55b", "name": "p1rlv20509", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "23176e93-7407-464d-bc9a-52c55cf5818d"}}}}, {"uuid": "ec46f3c7-03e2-4c29-94a5-0dc5d4fb3c9f", "name": "", "x": 38.580430683168224, "y": -122.51091156777555, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "485928ba-ff70-4be2-89ff-721ff82269fb", "name": "p1rdm14063", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ec46f3c7-03e2-4c29-94a5-0dc5d4fb3c9f"}}}}, {"uuid": "e216cc59-9ec4-4e42-9d09-5a00f7118d8d", "name": "", "x": 38.580046353830355, "y": -122.51078926317813, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b2f95b8b-190c-4df2-9dd2-daee5efde34b", "name": "p1rlv13671", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e216cc59-9ec4-4e42-9d09-5a00f7118d8d"}}}}, {"uuid": "248a8ebb-00ae-4a38-8a4f-10d10e9c56ef", "name": "", "x": 38.5800731009349, "y": -122.51072019695825, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "17936036-1191-4f91-bc12-2298db7b77e3", "name": "p1rlv13714", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "248a8ebb-00ae-4a38-8a4f-10d10e9c56ef"}}}}, {"uuid": "5aa22a9c-1ce1-4621-93e7-b53b9e38c72c", "name": "", "x": 38.580347829371135, "y": -122.51152987084961, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ad6bef77-8f39-43b4-b2d7-58aa6e45a60b", "name": "p1rdt6514lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5aa22a9c-1ce1-4621-93e7-b53b9e38c72c"}}}}, {"uuid": "10a7ab33-dca2-44a2-bc4d-09ca6dbebcfa", "name": "", "x": 38.57949879960493, "y": -122.51130960918293, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "80f60ab3-722f-4765-8b91-4fd0196171d7", "name": "p1rlv13623", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10a7ab33-dca2-44a2-bc4d-09ca6dbebcfa"}}}}, {"uuid": "ab4f132b-fd01-4949-81d2-a31a140fcc7e", "name": "", "x": 38.57935703047459, "y": -122.51121121339025, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bb3b4207-12ad-46e6-b4de-59149a46f8a1", "name": "p1rlv13716", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ab4f132b-fd01-4949-81d2-a31a140fcc7e"}}}}, {"uuid": "eefb9220-0cb8-4f72-885d-44b3115ed714", "name": "", "x": 38.58034931676033, "y": -122.51127026442917, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "395dac73-8fae-4718-a28c-191a76a298f2", "name": "p1rdm14072", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eefb9220-0cb8-4f72-885d-44b3115ed714"}}}}, {"uuid": "f49e9feb-241d-4ae8-a52f-be30473ffb53", "name": "", "x": 38.57957036570457, "y": -122.51118283635456, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "653bdc0d-5b21-4640-861b-b88ddb5c651a", "name": "p1rlv13640", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f49e9feb-241d-4ae8-a52f-be30473ffb53"}}}}, {"uuid": "31dfa6e7-23d1-4264-b514-b8738ffa1920", "name": "", "x": 38.58109531398495, "y": -122.50927974477071, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b92f8bcd-91ce-42bd-be69-0b43cb9d4122", "name": "p1rdt6515lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "31dfa6e7-23d1-4264-b514-b8738ffa1920"}}}}, {"uuid": "67a2a8dc-35a0-49b1-85b2-43530b524e93", "name": "", "x": 38.580433778313484, "y": -122.50861675365525, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4c667408-52a0-4258-8e93-557c94520a1e", "name": "p1rlv13625", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "67a2a8dc-35a0-49b1-85b2-43530b524e93"}}}}, {"uuid": "d632ea7f-fd46-4991-a3bf-ed80f588f4d9", "name": "", "x": 38.58052341301346, "y": -122.50850133423494, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7538ab85-10b4-4f60-98f8-179e954173b0", "name": "p1rlv19156", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d632ea7f-fd46-4991-a3bf-ed80f588f4d9"}}}}, {"uuid": "06e2a999-5f7e-46c8-bf9b-88a07f0a6653", "name": "", "x": 38.58046037950707, "y": -122.50851324468255, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fed6fcd4-3c97-4f62-a1a7-0b66394218e1", "name": "p1rlv19163", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "06e2a999-5f7e-46c8-bf9b-88a07f0a6653"}}}}, {"uuid": "df7ea0fc-8400-41d7-97a9-b5124ecf0dbb", "name": "", "x": 38.580379081602544, "y": -122.50846787535407, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ebd10471-ab4c-4cb7-a822-a83ef20e9854", "name": "p1rlv19165", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "df7ea0fc-8400-41d7-97a9-b5124ecf0dbb"}}}}, {"uuid": "71c50c0a-c945-48cf-90f3-ca1f580683fc", "name": "", "x": 38.58118341315065, "y": -122.50918052803313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c2659bd3-f6ca-4d74-87c8-f92596986cb5", "name": "p1rdm14075", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "71c50c0a-c945-48cf-90f3-ca1f580683fc"}}}}, {"uuid": "2943ec98-4018-405c-ac02-33c2cd62a6ce", "name": "", "x": 38.58079429345362, "y": -122.50862577812117, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1acad56e-b6d6-4fa7-a925-f242c1558eef", "name": "p1rlv13645", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2943ec98-4018-405c-ac02-33c2cd62a6ce"}}}}, {"uuid": "a3f4101a-c9ca-45b8-ab85-d07e7ec45422", "name": "", "x": 38.57910373167705, "y": -122.51042872774359, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "119a8559-8e6c-4314-9bbd-37ef3adde415", "name": "p1rdt6516lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a3f4101a-c9ca-45b8-ab85-d07e7ec45422"}}}}, {"uuid": "8578e75a-d652-46c2-a395-6865bcbad53c", "name": "", "x": 38.579216271561, "y": -122.51055379999012, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b4358536-b06f-486d-b336-3a8576b428d0", "name": "p1rlv13629", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8578e75a-d652-46c2-a395-6865bcbad53c"}}}}, {"uuid": "8432571b-e34a-43d5-9e64-26876c6c1f96", "name": "", "x": 38.57907136448223, "y": -122.51038257383402, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "db3908f7-94f5-43a7-a3de-1f6c9b72ebd4", "name": "p1rlv13638", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8432571b-e34a-43d5-9e64-26876c6c1f96"}}}}, {"uuid": "fc5a608f-136d-45a3-b9d3-55b3b6c1f5d9", "name": "", "x": 38.57899879076654, "y": -122.51026826026441, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "091b545a-eb31-4bea-a0a6-5aa9c7a8397f", "name": "p1rlv13692", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fc5a608f-136d-45a3-b9d3-55b3b6c1f5d9"}}}}, {"uuid": "40f54f9d-097d-45d1-a5d8-f1a1f6a5fc6b", "name": "", "x": 38.579225763250356, "y": -122.51066854219654, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5a230534-6927-4af8-ba54-6ab4c9c32d21", "name": "p1rlv13708", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "40f54f9d-097d-45d1-a5d8-f1a1f6a5fc6b"}}}}, {"uuid": "7af31148-260a-4af0-929e-efbf262969e1", "name": "", "x": 38.578028811911885, "y": -122.51471027861992, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5783bae9-2c74-473f-bf18-db40bc975409", "name": "p1rdt6517lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7af31148-260a-4af0-929e-efbf262969e1"}}}}, {"uuid": "44e91cd6-7c3b-4399-82ed-b6d033f98399", "name": "", "x": 38.577889883003294, "y": -122.51448911519815, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f474e4ba-6300-4014-afe9-c245e08cf3c5", "name": "p1rlv13630", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "44e91cd6-7c3b-4399-82ed-b6d033f98399"}}}}, {"uuid": "7bdf2223-6574-4b58-aadb-d8e61843899a", "name": "", "x": 38.577945523946006, "y": -122.51486759582244, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "822f96e6-61c5-455d-8a53-a494b49c9237", "name": "p1rdm14084", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7bdf2223-6574-4b58-aadb-d8e61843899a"}}}}, {"uuid": "a906ae70-357e-4896-84e5-143cc3bd8545", "name": "", "x": 38.577881918670876, "y": -122.51474173870584, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4eb10938-4b73-406c-bed4-0bd01e0bc20d", "name": "p1rlv13641", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a906ae70-357e-4896-84e5-143cc3bd8545"}}}}, {"uuid": "143669c5-e2c1-4511-91b3-1ce3d7e385ed", "name": "", "x": 38.575528992640834, "y": -122.51891559878237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d9b16b03-1922-4aeb-8e70-d0e1387fbcab", "name": "p1rdt6518lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "143669c5-e2c1-4511-91b3-1ce3d7e385ed"}}}}, {"uuid": "9602fb20-3991-42c9-a5a7-a99c1dea8d9b", "name": "", "x": 38.5754218018766, "y": -122.51914367215898, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a8753d37-07f1-45c6-a483-43cbfb6bf107", "name": "p1rlv13647", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9602fb20-3991-42c9-a5a7-a99c1dea8d9b"}}}}, {"uuid": "5f715d2f-2c1a-4619-96c9-21d42566e2be", "name": "", "x": 38.57580840851501, "y": -122.51892297252556, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c597db56-a6af-472d-a7a2-e331175a2aae", "name": "p1rdm14085", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5f715d2f-2c1a-4619-96c9-21d42566e2be"}}}}, {"uuid": "bba05f6a-3c85-4a4a-81a0-c367140f6a1f", "name": "", "x": 38.57579807527307, "y": -122.51860159809428, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7b712121-d0c2-488a-9224-bea72928796f", "name": "p1rlv13632", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bba05f6a-3c85-4a4a-81a0-c367140f6a1f"}}}}, {"uuid": "df87e52c-507b-4c49-89b5-d67af8264dd1", "name": "", "x": 38.57533041118428, "y": -122.51883432018805, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "180c5680-acd1-4988-ac36-1f351c3f9418", "name": "p1rdm14087", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "df87e52c-507b-4c49-89b5-d67af8264dd1"}}}}, {"uuid": "4395a690-5c9a-46b3-adb7-ac922592d62f", "name": "", "x": 38.57533575960138, "y": -122.51944669646048, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "02f2e50e-d42d-47d1-9274-d840042b64d1", "name": "p1rlv20154", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4395a690-5c9a-46b3-adb7-ac922592d62f"}}}}, {"uuid": "11000b69-6f7e-48dc-859f-2cdd46f95489", "name": "", "x": 38.575287380857716, "y": -122.5193282488865, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "11a125b8-023c-4748-98a9-d74e9e0a7d23", "name": "p1rlv20161", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "11000b69-6f7e-48dc-859f-2cdd46f95489"}}}}, {"uuid": "ee4d4eec-5dfb-4f0b-b0f6-1164bf7d8847", "name": "", "x": 38.58088300114921, "y": -122.50941317390307, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "606673ea-bcd2-459a-a0af-efb8b31c600c", "name": "p1rdt6519lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ee4d4eec-5dfb-4f0b-b0f6-1164bf7d8847"}}}}, {"uuid": "d8ed7224-a9d9-4391-b993-936a9f14dbc6", "name": "", "x": 38.58045459525182, "y": -122.5092825015312, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d4d3fe62-b327-4fc6-b2aa-795c9475019a", "name": "p1rlv13636", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d8ed7224-a9d9-4391-b993-936a9f14dbc6"}}}}, {"uuid": "cc47d065-a18b-4a0d-bbb1-a923026636c1", "name": "", "x": 38.5808931056819, "y": -122.50952733350167, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3e06b069-62f8-40c8-9abc-d4cc83937e41", "name": "p1rdm14090", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc47d065-a18b-4a0d-bbb1-a923026636c1"}}}}, {"uuid": "8316b40c-759e-4de9-82e2-b7599bcc368e", "name": "", "x": 38.58036317851489, "y": -122.5089731408155, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32b75c61-4e97-4e21-a786-8aab7a2d88f8", "name": "p1rlv13678", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8316b40c-759e-4de9-82e2-b7599bcc368e"}}}}, {"uuid": "2b9af43c-355e-4977-af5d-fe2deaa37cb9", "name": "", "x": 38.580046706763056, "y": -122.51235461842337, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "13c02cd3-cff3-4988-95b9-3993b9541427", "name": "p1rdt6520lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2b9af43c-355e-4977-af5d-fe2deaa37cb9"}}}}, {"uuid": "07a6bf40-9c43-494c-a5e0-aedfb16e2e8b", "name": "", "x": 38.580041773656525, "y": -122.51253040494485, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5484eab0-53a8-471c-92ec-29c11c08e740", "name": "p1rlv13639", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "07a6bf40-9c43-494c-a5e0-aedfb16e2e8b"}}}}, {"uuid": "d1a1887e-68b9-4ba7-bb1e-9559ec608ccd", "name": "", "x": 38.5799894527048, "y": -122.51227067031124, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "607d3b54-2cea-476b-afe2-ea40c6c02ddc", "name": "p1rlv13669", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1a1887e-68b9-4ba7-bb1e-9559ec608ccd"}}}}, {"uuid": "0a2e9171-72f9-4d27-851c-45eabbd30ece", "name": "", "x": 38.57993605226405, "y": -122.51243176231385, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "db3abe20-2ffb-4bf8-b425-5613701bd3f2", "name": "p1rdm14092", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a2e9171-72f9-4d27-851c-45eabbd30ece"}}}}, {"uuid": "3e3df82e-7e0f-40fc-aef7-434dfc7f6cd8", "name": "", "x": 38.579872492217575, "y": -122.51231738436074, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2e55b944-ffad-47bf-8348-799afa4c7a1d", "name": "p1rlv13662", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e3df82e-7e0f-40fc-aef7-434dfc7f6cd8"}}}}, {"uuid": "7ede4855-ada0-4ba8-b0c6-2cef3422a414", "name": "", "x": 38.57984627020021, "y": -122.51251273462697, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c0c27b40-83a9-4938-bc12-a2ae57d5eafb", "name": "p1rdm14096", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7ede4855-ada0-4ba8-b0c6-2cef3422a414"}}}}, {"uuid": "88e1daf5-aee2-4047-8cda-6569b0fbeae0", "name": "", "x": 38.57983668465647, "y": -122.51237503029868, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "284bbc5d-bb49-404d-823e-08ec543c90b8", "name": "p1rlv13679", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "88e1daf5-aee2-4047-8cda-6569b0fbeae0"}}}}, {"uuid": "a229c490-a965-4a8a-b3d8-c55d37bf829d", "name": "", "x": 38.57981055069724, "y": -122.51248335572157, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eb3a7829-4233-4af9-9679-08bd114bc00e", "name": "p1rdm14097", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a229c490-a965-4a8a-b3d8-c55d37bf829d"}}}}, {"uuid": "9ccf5d63-0b54-4e31-90f0-2d4a9ce2a633", "name": "", "x": 38.57972969205857, "y": -122.51265129155006, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4f409299-5ac0-4f31-a217-d0aef7fbc4d2", "name": "p1rlv13705", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9ccf5d63-0b54-4e31-90f0-2d4a9ce2a633"}}}}, {"uuid": "8f222518-4a99-4211-9e54-fd4adc5c5032", "name": "", "x": 38.58009749717621, "y": -122.51224697801528, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8a990c6c-4227-4896-8ea6-e92ce5360087", "name": "p1rdm14094", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8f222518-4a99-4211-9e54-fd4adc5c5032"}}}}, {"uuid": "fa7fa1c1-aa2d-4cac-bf81-c50e1d993e77", "name": "", "x": 38.580215414329274, "y": -122.51242987363875, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9467d2d3-ad80-4bc7-aa9f-cd6e76494552", "name": "p1rlv13673", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa7fa1c1-aa2d-4cac-bf81-c50e1d993e77"}}}}, {"uuid": "9bc63553-29f4-4a9a-b99b-5521c3a3c329", "name": "", "x": 38.58029613681535, "y": -122.51233748122965, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c532e298-bdd5-416e-8ebe-a082489ffee6", "name": "p1rlv13675", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9bc63553-29f4-4a9a-b99b-5521c3a3c329"}}}}, {"uuid": "d688086c-831c-45c9-9d48-2f297d145d3d", "name": "", "x": 38.5803966658545, "y": -122.51095681258643, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d0e4e42c-8dcd-47be-bfe8-b8b1eb4a5f24", "name": "p1rdt6521lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d688086c-831c-45c9-9d48-2f297d145d3d"}}}}, {"uuid": "c69b4e5a-4201-42e7-810c-2cf0ebcc7981", "name": "", "x": 38.579486477877886, "y": -122.51051752411439, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ce53d307-fc73-487a-8f6a-3a0e0787bf79", "name": "p1rlv13670", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c69b4e5a-4201-42e7-810c-2cf0ebcc7981"}}}}, {"uuid": "690138af-24c1-49be-867e-6680bd0377bf", "name": "", "x": 38.57976641593619, "y": -122.51065339312383, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1de2ebf2-3207-4bf7-9702-4c729d99a6cf", "name": "p1rlv13694", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "690138af-24c1-49be-867e-6680bd0377bf"}}}}, {"uuid": "1a45c60d-d023-4cae-a611-68068c4a0593", "name": "", "x": 38.579567775011846, "y": -122.51056289521121, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d73963d7-acf4-48b3-8e54-6ee9f403d36f", "name": "p1rlv13695", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1a45c60d-d023-4cae-a611-68068c4a0593"}}}}, {"uuid": "caab1a9d-2a8c-4eed-959a-9039332e3168", "name": "", "x": 38.58050191288654, "y": -122.51070442912985, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c12be3d4-719e-4567-91d9-c0ff24b783f1", "name": "p1rdm14098", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "caab1a9d-2a8c-4eed-959a-9039332e3168"}}}}, {"uuid": "754ba22d-779c-4aa4-b7ce-548fb7f221dc", "name": "", "x": 38.579756732183114, "y": -122.51049272837687, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "479d1486-ed05-44fa-8fab-64035623f267", "name": "p1rlv13642", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "754ba22d-779c-4aa4-b7ce-548fb7f221dc"}}}}, {"uuid": "4d31dd12-f830-474c-9bda-1130c7c4b4f8", "name": "", "x": 38.58037890435985, "y": -122.51109366072052, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1db9a47a-f0ed-4141-b08e-f01a2ffd804f", "name": "p1rdm14100", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d31dd12-f830-474c-9bda-1130c7c4b4f8"}}}}, {"uuid": "8a46299e-61ca-4b07-a11b-4ca253e6e6cf", "name": "", "x": 38.57950522126574, "y": -122.51068960750169, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9a3c050c-cc0d-460e-af02-ce3421431474", "name": "p1rlv13682", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8a46299e-61ca-4b07-a11b-4ca253e6e6cf"}}}}, {"uuid": "c77f9530-ec0a-4054-9a05-006d849ef1ad", "name": "", "x": 38.57973678683187, "y": -122.51254142741766, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "66df2481-ae4f-4f39-aef4-7af09ce1a8fb", "name": "p1rdt6523lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c77f9530-ec0a-4054-9a05-006d849ef1ad"}}}}, {"uuid": "f39c6dd4-71cf-4d64-bcb4-da1faefa9fbc", "name": "", "x": 38.5799209440274, "y": -122.51313219164904, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "43867e2f-79ee-4cec-bed3-0cad0727118c", "name": "p1rlv13649", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f39c6dd4-71cf-4d64-bcb4-da1faefa9fbc"}}}}, {"uuid": "38154626-549f-4873-8768-aab4b840920b", "name": "", "x": 38.58054870314674, "y": -122.51023477359377, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2844042b-3f65-4a8b-8bab-56b42971e6ad", "name": "p1rdm14107", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "38154626-549f-4873-8768-aab4b840920b"}}}}, {"uuid": "28d5033a-494a-4830-857c-27385f72f97e", "name": "", "x": 38.58037752934179, "y": -122.51024741691637, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e8c0a04e-6e22-4da5-9907-7ae8097deb10", "name": "p1rlv13656", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "28d5033a-494a-4830-857c-27385f72f97e"}}}}, {"uuid": "6a791e00-55dc-4756-be50-d51a7faea780", "name": "", "x": 38.58064802372938, "y": -122.51028002263617, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "71c26ca3-0d61-46b8-a95b-710e0b760b62", "name": "p1rlv13690", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a791e00-55dc-4756-be50-d51a7faea780"}}}}, {"uuid": "1307498e-2f33-4f26-9a24-ed1f4799a1a1", "name": "", "x": 38.580549321580946, "y": -122.51038626364308, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0ec2137a-f978-4808-a023-21f13464998b", "name": "p1rdt6524lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1307498e-2f33-4f26-9a24-ed1f4799a1a1"}}}}, {"uuid": "97e975d1-b903-4ebf-b362-88304a9e927a", "name": "", "x": 38.58052253264507, "y": -122.51044160695697, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2256f06d-59e9-4822-987f-7d26f40415c0", "name": "p1rdm14109", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "97e975d1-b903-4ebf-b362-88304a9e927a"}}}}, {"uuid": "980817ce-f98e-4842-9e4e-62861e103709", "name": "", "x": 38.58056754300597, "y": -122.51042982053421, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ecf9ee9-2a3c-431b-84c8-02c7c7aaacb1", "name": "p1rlv13700", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "980817ce-f98e-4842-9e4e-62861e103709"}}}}, {"uuid": "6b9561d7-37ff-4c73-939a-cae0bfc6f012", "name": "", "x": 38.579048350921525, "y": -122.51041447766671, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f8905812-7e3b-4875-87b5-da95999c5bb0", "name": "p1rdt6527lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6b9561d7-37ff-4c73-939a-cae0bfc6f012"}}}}, {"uuid": "171206bc-5e24-403f-8776-7735ef98c781", "name": "", "x": 38.57906268295511, "y": -122.51046524008142, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ef8e6ec-86d3-429c-89b4-6c7260701e70", "name": "p1rlv13661", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "171206bc-5e24-403f-8776-7735ef98c781"}}}}, {"uuid": "29a9d0b7-9834-4fb6-9592-8530158d8ade", "name": "", "x": 38.581032746102906, "y": -122.50929836357719, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d097d9be-dd3a-4616-a873-8ab5013c4e72", "name": "p1rdt6528lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "29a9d0b7-9834-4fb6-9592-8530158d8ade"}}}}, {"uuid": "b43a9112-3dd0-4606-b9e2-b2c280cccd50", "name": "", "x": 38.580921613298514, "y": -122.50890045296518, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d6cdd514-204d-4a86-b0f3-a9bc4990a2aa", "name": "p1rlv13667", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b43a9112-3dd0-4606-b9e2-b2c280cccd50"}}}}, {"uuid": "7b51efa8-65e3-4715-b4c4-3e3fc9865126", "name": "", "x": 38.58083655075754, "y": -122.508633001311, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "850df31b-ee95-4903-93b7-6e5911e8f8a0", "name": "p1rlv13691", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7b51efa8-65e3-4715-b4c4-3e3fc9865126"}}}}, {"uuid": "7124613f-6902-4611-8bf2-0685d7cdd0ca", "name": "", "x": 38.581173273294354, "y": -122.50945964206286, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b51fe8ae-f6d7-48c7-9f84-22fc7c1c1ba9", "name": "p1rdm14115", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7124613f-6902-4611-8bf2-0685d7cdd0ca"}}}}, {"uuid": "f6ed6571-05e2-410b-a5cb-bc043ce84079", "name": "", "x": 38.58081366588884, "y": -122.50894711172428, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6e5db11f-0418-4119-9c71-26619456fd7b", "name": "p1rlv13689", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f6ed6571-05e2-410b-a5cb-bc043ce84079"}}}}, {"uuid": "f1617a39-6b0b-473b-925f-e682bab9adfc", "name": "", "x": 38.57747782265656, "y": -122.51577372256881, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e4ee2d3a-e97c-4ec4-9fa0-d7db1b3e9253", "name": "p1rdt6530lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f1617a39-6b0b-473b-925f-e682bab9adfc"}}}}, {"uuid": "3e778788-41ab-4bac-aa92-c2f1a99a4d9e", "name": "", "x": 38.57719931368139, "y": -122.51529738764073, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ec49353-14d1-4917-83bc-ca62cd94bf30", "name": "p1rlv13684", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e778788-41ab-4bac-aa92-c2f1a99a4d9e"}}}}, {"uuid": "b3fcdf02-4c33-493d-9575-5ea120899df5", "name": "", "x": 38.578752758421444, "y": -122.51042399893916, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bf4a2da0-682a-4119-b398-feaa6f5a8498", "name": "p1rdt6531lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b3fcdf02-4c33-493d-9575-5ea120899df5"}}}}, {"uuid": "dc1038de-320a-4318-bcb0-e653ac19b58f", "name": "", "x": 38.57871154896236, "y": -122.51041164293123, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c5815b75-1226-4221-9bcb-bc75ce85fa17", "name": "p1rlv13693", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dc1038de-320a-4318-bcb0-e653ac19b58f"}}}}, {"uuid": "95a9d089-ce98-467f-8ea9-9b42f507f74f", "name": "", "x": 38.58148963770846, "y": -122.5089654708908, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75c95c35-ea3f-4958-9512-606f78de92b5", "name": "p1rdm14120", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "95a9d089-ce98-467f-8ea9-9b42f507f74f"}}}}, {"uuid": "d03f9226-6e80-4991-b4fc-56e75e294b1f", "name": "", "x": 38.581272297668534, "y": -122.50871436904568, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e60fc98a-9c1d-4975-a9b9-e37271b4ac81", "name": "p1rlv13706", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d03f9226-6e80-4991-b4fc-56e75e294b1f"}}}}, {"uuid": "3c14900e-d03a-4b45-805a-10573b24aa91", "name": "", "x": 38.58157778587544, "y": -122.50884357066717, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c0c3e71a-52a1-49b9-a899-c13d639ac0a6", "name": "p1rdt6532lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3c14900e-d03a-4b45-805a-10573b24aa91"}}}}, {"uuid": "9540f591-cdc2-440a-94fd-1e5f0e14566d", "name": "", "x": 38.581615271240324, "y": -122.50883832397932, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7194199d-e430-4b76-ae77-4c7f51477eed", "name": "p1rdm14121", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9540f591-cdc2-440a-94fd-1e5f0e14566d"}}}}, {"uuid": "fcad0d46-75ae-46e8-b3c1-38c221ef9313", "name": "", "x": 38.5814179357273, "y": -122.50838439741678, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6e396aca-4116-40a0-8f17-bcd41f709ea5", "name": "p1rlv19151", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fcad0d46-75ae-46e8-b3c1-38c221ef9313"}}}}, {"uuid": "e22ae8fc-869d-4fcc-a72c-f32024a9b73d", "name": "", "x": 38.58107483274763, "y": -122.50959807912284, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "10f0e9fa-75b8-4eaa-a2ad-b6a3fb4ae859", "name": "p1rdt6535lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e22ae8fc-869d-4fcc-a72c-f32024a9b73d"}}}}, {"uuid": "0bddd491-bc72-4bbc-94d6-54da98b4518e", "name": "", "x": 38.58061410818166, "y": -122.50863848671041, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d2bfaa34-267c-4dfd-8b6d-4ab444ac4048", "name": "p1rlv13711", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0bddd491-bc72-4bbc-94d6-54da98b4518e"}}}}, {"uuid": "88973f79-5169-4a1b-921d-7cd7c4ba37ab", "name": "", "x": 38.58093200049442, "y": -122.50908714544045, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b93e7299-60a4-49d6-9d34-885860588861", "name": "p1rdt6536lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "88973f79-5169-4a1b-921d-7cd7c4ba37ab"}}}}, {"uuid": "cd358d57-6ede-4102-b78b-91c55b2a32d8", "name": "", "x": 38.58096835695191, "y": -122.50930196751384, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ee766a99-bb6f-4d5c-8513-9d462103f6fc", "name": "p1rlv13713", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cd358d57-6ede-4102-b78b-91c55b2a32d8"}}}}, {"uuid": "3c0b623a-bb42-42e7-96ad-2d9e0d3d3aed", "name": "", "x": 38.58099515130269, "y": -122.50924438048082, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a0f1846b-2515-48ef-9241-0276932f8e75", "name": "p1rlv13723", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3c0b623a-bb42-42e7-96ad-2d9e0d3d3aed"}}}}, {"uuid": "19e3403c-a263-4796-b98b-3831b386ca8d", "name": "", "x": 38.58098269315429, "y": -122.5094004338482, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "57ac4a24-2ddb-46c2-873d-c0b4f3e0600a", "name": "p1rdm14127", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "19e3403c-a263-4796-b98b-3831b386ca8d"}}}}, {"uuid": "d78ff223-7105-40b8-bf1b-61b854c6f63a", "name": "", "x": 38.581152353955275, "y": -122.50952282376217, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cd0effe0-d186-41a8-8197-24144fbc6218", "name": "p1rlv20478", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d78ff223-7105-40b8-bf1b-61b854c6f63a"}}}}, {"uuid": "14987673-7f92-410c-ab47-2773ed46e137", "name": "", "x": 38.575043333110195, "y": -122.51764982578192, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b34f50ff-9a1f-439e-81a8-dfcee658926b", "name": "p1rdt6539lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "14987673-7f92-410c-ab47-2773ed46e137"}}}}, {"uuid": "1276727e-e436-4f80-afa1-9972acfe3f6f", "name": "", "x": 38.57528171570155, "y": -122.51795068214895, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "36019623-eb62-412c-a591-41494980c9b7", "name": "p1rlv13727", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1276727e-e436-4f80-afa1-9972acfe3f6f"}}}}, {"uuid": "016059b9-2ab8-4187-9495-83fc87cb1e18", "name": "", "x": 38.57506491492146, "y": -122.51782585098714, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "006c2753-37b3-4b59-82a6-8ce95f316e26", "name": "p1rlv20450", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "016059b9-2ab8-4187-9495-83fc87cb1e18"}}}}, {"uuid": "51262455-014d-42fc-a2c6-b55e1fecf6c2", "name": "", "x": 38.660324342235185, "y": -122.44998273762167, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "36ab64e0-65cb-4515-9c06-4762a398672a", "name": "p1rdm14185", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "51262455-014d-42fc-a2c6-b55e1fecf6c2"}}}}, {"uuid": "b6bdd6fb-bd85-419a-818b-875257aff1db", "name": "", "x": 38.6601489758078, "y": -122.44970425964786, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "01a18948-75cf-4caf-951f-17a9c8d1f6bc", "name": "p1rlv13784", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b6bdd6fb-bd85-419a-818b-875257aff1db"}}}}, {"uuid": "9f0f8df4-1f7f-44b5-9ff9-a1e84cc3bf9c", "name": "", "x": 38.660528052085354, "y": -122.4498277884296, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4a43920a-a200-40fe-b5b6-3cdba0c7e784", "name": "p1rdt6574lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9f0f8df4-1f7f-44b5-9ff9-a1e84cc3bf9c"}}}}, {"uuid": "1af54902-4345-44cc-8578-75cb2bb7fef3", "name": "", "x": 38.66069273125682, "y": -122.44975004725573, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7f2b4d47-9668-4bcc-933b-1f422f423e3e", "name": "p1rdm14186", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1af54902-4345-44cc-8578-75cb2bb7fef3"}}}}, {"uuid": "c7901057-6ff0-4903-aead-e90a06af9e66", "name": "", "x": 38.66068307092049, "y": -122.44961219759635, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ffd737b-a273-4a6c-91c6-351b5719f658", "name": "p1rlv13812", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c7901057-6ff0-4903-aead-e90a06af9e66"}}}}, {"uuid": "8b51ed47-dfcb-4c2e-ac55-4c15c9ca7323", "name": "", "x": 38.659329203857624, "y": -122.45168740029418, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "608e485b-13ce-493b-be96-ab83ad733c92", "name": "p1rdt6581lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8b51ed47-dfcb-4c2e-ac55-4c15c9ca7323"}}}}, {"uuid": "f950a428-2ee0-42b5-bca3-f9b32c5e4d26", "name": "", "x": 38.66001044613518, "y": -122.45222637580909, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "65052833-aec9-4363-a0cf-4d70fa9bb0ce", "name": "p1rlv13797", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f950a428-2ee0-42b5-bca3-f9b32c5e4d26"}}}}, {"uuid": "44852aa5-fa2c-4502-9c7e-66f3665c8c8e", "name": "", "x": 38.65980253637742, "y": -122.45209003761849, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0aef2ef8-706c-4316-be01-0707ddf0ac7c", "name": "p1rlv13811", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "44852aa5-fa2c-4502-9c7e-66f3665c8c8e"}}}}, {"uuid": "405d3e33-0803-4bab-bab6-03ae336215f7", "name": "", "x": 38.659439276645934, "y": -122.45149514678252, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b8b7c677-d0bf-47d0-8a2a-78417faa49b9", "name": "p1rdm14205", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "405d3e33-0803-4bab-bab6-03ae336215f7"}}}}, {"uuid": "d0122f2a-41cc-4246-90f8-a04abd00afa7", "name": "", "x": 38.660111562159514, "y": -122.45204568307697, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dc5fcb56-435a-4a0d-b442-7489a98ad1cd", "name": "p1rlv13792", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d0122f2a-41cc-4246-90f8-a04abd00afa7"}}}}, {"uuid": "7d3f6c6b-b89e-4239-8ced-0de9f6cea967", "name": "", "x": 38.65993673921714, "y": -122.45188213185789, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c9725b6c-5bac-456a-bb6a-ce16a5e6b1a5", "name": "p1rlv13794", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7d3f6c6b-b89e-4239-8ced-0de9f6cea967"}}}}, {"uuid": "5807dfff-f120-476d-b028-21c8ea93379e", "name": "", "x": 38.66019931022639, "y": -122.45214448227058, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "83d60921-a1f2-4b9c-9709-d2be59b82db5", "name": "p1rlv13805", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5807dfff-f120-476d-b028-21c8ea93379e"}}}}, {"uuid": "762a9906-8f58-46f4-8c29-6a02b47cc88d", "name": "", "x": 38.65918069105062, "y": -122.45208328210967, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "487eef02-df2d-47fe-a20b-ce1c23064495", "name": "p1rdm14210", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "762a9906-8f58-46f4-8c29-6a02b47cc88d"}}}}, {"uuid": "883511c6-7a7d-486b-8068-fcb271ee85b0", "name": "", "x": 38.65967739844402, "y": -122.45230936703297, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "604cb559-0f18-4ef7-8bcd-a07a7e7f96d7", "name": "p1rlv19691", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "883511c6-7a7d-486b-8068-fcb271ee85b0"}}}}, {"uuid": "93ef6245-d527-43bb-bc70-7d08a2b64e0e", "name": "", "x": 38.6320710830909, "y": -122.46441945032754, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e7b9897e-b820-424c-adf8-7416de585357", "name": "p1rdt6847lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "93ef6245-d527-43bb-bc70-7d08a2b64e0e"}}}}, {"uuid": "7ee9b2d7-249f-4fa4-85bc-5e321dccdcdf", "name": "", "x": 38.632085435147204, "y": -122.46447024061165, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "06135bd7-6a77-4f04-a439-4ce8c245447d", "name": "p1rlv14434", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7ee9b2d7-249f-4fa4-85bc-5e321dccdcdf"}}}}, {"uuid": "d54e3cca-aebe-44b5-9000-f52ec82f8845", "name": "", "x": 38.62923340048788, "y": -122.45439823840434, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "94c9fa37-fc5c-4243-b0ca-f70840febaee", "name": "p1rdt6848lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d54e3cca-aebe-44b5-9000-f52ec82f8845"}}}}, {"uuid": "ead318c5-17a0-4d28-9e0b-0029efe1f9ba", "name": "", "x": 38.62920980622029, "y": -122.45452876435519, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d07f5065-df41-484d-8e8a-80b2ff4e0e9b", "name": "p1rlv14435", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ead318c5-17a0-4d28-9e0b-0029efe1f9ba"}}}}, {"uuid": "ef518207-8f21-4771-84fd-ac07da8214a1", "name": "", "x": 38.62930775436262, "y": -122.45427527251405, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ad66e41a-88ab-443e-b10e-9e7b5b899119", "name": "p1rlv14436", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef518207-8f21-4771-84fd-ac07da8214a1"}}}}, {"uuid": "1ee5b07a-7cbd-4569-b1aa-52fb1b80f325", "name": "", "x": 38.648478696952125, "y": -122.39365801344734, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "09a476ff-48a0-4d27-9cf0-c007e2e98acb", "name": "p1rdt6995lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1ee5b07a-7cbd-4569-b1aa-52fb1b80f325"}}}}, {"uuid": "c4dd9eca-e51f-46cd-9b27-abc8d242acdf", "name": "", "x": 38.6484526903026, "y": -122.39361541442939, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c9efa4c9-9832-4aa8-bf44-be0fe1e80cd5", "name": "p1rlv14828", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c4dd9eca-e51f-46cd-9b27-abc8d242acdf"}}}}, {"uuid": "a6befc82-8adc-4a0d-a14e-865e43d77c0a", "name": "", "x": 38.64916844328969, "y": -122.39459452477139, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "536d7c56-85a6-4167-b4f6-2f39936cd662", "name": "p1rdt7015lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a6befc82-8adc-4a0d-a14e-865e43d77c0a"}}}}, {"uuid": "d69748df-ccc3-48ce-9654-18f617d9fb69", "name": "", "x": 38.64918282560407, "y": -122.39464531276182, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d73b0321-e181-4ecd-b431-9aa6985d56d0", "name": "p1rlv14908", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d69748df-ccc3-48ce-9654-18f617d9fb69"}}}}, {"uuid": "8fcb6705-048d-4877-a0bc-e606511d2295", "name": "", "x": 38.56296537249011, "y": -122.50762584426352, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1a371c8b-1993-432c-b2c6-21b18bec27da", "name": "p1rdt7036lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8fcb6705-048d-4877-a0bc-e606511d2295"}}}}, {"uuid": "9037b898-87b5-4754-92ad-23b3c26383e7", "name": "", "x": 38.56302965746093, "y": -122.50745371127641, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3c39b0c-9c92-4934-876f-ee5f542f95cc", "name": "p1rlv14952", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9037b898-87b5-4754-92ad-23b3c26383e7"}}}}, {"uuid": "125c32e8-53ea-4b99-a462-4873a5fbd551", "name": "", "x": 38.562911104383154, "y": -122.50779489358709, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "260ea1f0-7235-47fc-a576-3d647618290e", "name": "p1rdm15468", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "125c32e8-53ea-4b99-a462-4873a5fbd551"}}}}, {"uuid": "dfd993e3-9f3d-4b0c-bd6a-abd0bcfed918", "name": "", "x": 38.56269409956021, "y": -122.50762420325977, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "19231152-1fd1-4e07-a5d9-603c765b2cae", "name": "p1rlv15008", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dfd993e3-9f3d-4b0c-bd6a-abd0bcfed918"}}}}, {"uuid": "adac6dc8-8be6-48fb-949a-6b94d12f7d4b", "name": "", "x": 38.56256229551184, "y": -122.50269706817427, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "046f6c53-8d9c-43a1-88ce-169ade9e9557", "name": "p1rdt7038lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "adac6dc8-8be6-48fb-949a-6b94d12f7d4b"}}}}, {"uuid": "8ca7ccc6-e0d8-4b03-856f-60ac9d14b366", "name": "", "x": 38.562607012632625, "y": -122.50261641391278, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a9e128f5-eb18-44df-8ec4-35bd049ef630", "name": "p1rlv14954", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8ca7ccc6-e0d8-4b03-856f-60ac9d14b366"}}}}, {"uuid": "e911b985-e79e-4f2c-93b3-ef325ec3ea1e", "name": "", "x": 38.56228530015727, "y": -122.50538482056976, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cd6a9808-9889-4f16-825d-c9763357c293", "name": "p1rdt7046lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e911b985-e79e-4f2c-93b3-ef325ec3ea1e"}}}}, {"uuid": "859e95c6-17e7-4a0d-9a9d-6892808b6de9", "name": "", "x": 38.56236063103573, "y": -122.50548009684834, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "884ff47e-8e20-4ae8-97bd-287d0ca9dc1b", "name": "p1rlv14974", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "859e95c6-17e7-4a0d-9a9d-6892808b6de9"}}}}, {"uuid": "971c2a17-55d8-4d9f-9371-a6f61aafe5a7", "name": "", "x": 38.558417547967906, "y": -122.507932804306, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf93e681-3ab6-4929-95f1-1da6d5dd28fa", "name": "p1rdt7054lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "971c2a17-55d8-4d9f-9371-a6f61aafe5a7"}}}}, {"uuid": "08d23886-0c5d-44c8-b2ad-7ea381317beb", "name": "", "x": 38.55834318385272, "y": -122.50806707079614, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f4f8b1bc-83c3-4819-9d98-9491df98d494", "name": "p1rlv14992", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "08d23886-0c5d-44c8-b2ad-7ea381317beb"}}}}, {"uuid": "2b6a7bde-a0c4-449f-8fe4-d8400882bf90", "name": "", "x": 38.55812685464717, "y": -122.50805706795369, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a914ec3a-4883-42a7-b25d-133a1410b8d9", "name": "p1rlv15056", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2b6a7bde-a0c4-449f-8fe4-d8400882bf90"}}}}, {"uuid": "5e15ee0b-3693-41ac-8cb0-055c517b69d7", "name": "", "x": 38.558469106593094, "y": -122.50800882572935, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25a6c92d-ea7f-4ede-af16-713ceedfc7b0", "name": "p1rdm15533", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5e15ee0b-3693-41ac-8cb0-055c517b69d7"}}}}, {"uuid": "356f834c-0b74-448a-bb21-123afc00d12d", "name": "", "x": 38.558289451182375, "y": -122.50814777833953, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2182c9fd-fd3d-4cb1-b525-192480823e2f", "name": "p1rlv15046", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "356f834c-0b74-448a-bb21-123afc00d12d"}}}}, {"uuid": "1aaf2a4d-ff03-454e-a713-9582309fa5ce", "name": "", "x": 38.559657411750145, "y": -122.50277093263843, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bc33ade7-4471-40b8-8e9b-1846e0ad60e8", "name": "p1rdt7061lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1aaf2a4d-ff03-454e-a713-9582309fa5ce"}}}}, {"uuid": "637627d3-e56a-4bc8-9ff8-1a6c5760087b", "name": "", "x": 38.55937583329394, "y": -122.50291811146595, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cc29de5b-3a3f-40c0-bde4-9a57f5f62b5c", "name": "p1rlv15007", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "637627d3-e56a-4bc8-9ff8-1a6c5760087b"}}}}, {"uuid": "2c405f7c-6e09-4705-a315-e45355677bb1", "name": "", "x": 38.563364746370645, "y": -122.50424505524006, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f4445ca5-2fed-4352-ab78-66e072a4f482", "name": "p1rdm15583", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2c405f7c-6e09-4705-a315-e45355677bb1"}}}}, {"uuid": "55ebc70c-c0d4-4a17-bcc7-8a77aee0e74b", "name": "", "x": 38.56324735128747, "y": -122.50418847116366, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "07e3b847-cc9a-4f84-bc00-cb4396b6dea0", "name": "p1rlv15027", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "55ebc70c-c0d4-4a17-bcc7-8a77aee0e74b"}}}}, {"uuid": "c5817b8f-ea88-454f-88ee-92b03f9a1ddf", "name": "", "x": 38.56307400876931, "y": -122.50435786467884, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1ff878e1-3143-4f8e-aa92-74d0a9046417", "name": "p1rdt7067lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c5817b8f-ea88-454f-88ee-92b03f9a1ddf"}}}}, {"uuid": "a34ca3d2-08f9-4046-8516-8323c5dbc0bb", "name": "", "x": 38.562913772741126, "y": -122.50415632890832, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5ad4c131-0be7-46e5-8a32-5ff92552dfe6", "name": "p1rdm15584", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a34ca3d2-08f9-4046-8516-8323c5dbc0bb"}}}}, {"uuid": "e8c80a4b-9086-4dc3-828c-6661b91adb34", "name": "", "x": 38.563057133200985, "y": -122.50396021637685, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "80a74c6f-c9ec-4742-8fce-ad73c0a6c459", "name": "p1rlv15197", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e8c80a4b-9086-4dc3-828c-6661b91adb34"}}}}, {"uuid": "63c74f01-b8e6-49bc-8ad2-88e28191cae0", "name": "", "x": 38.559099227598956, "y": -122.50637076262426, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9a1566f1-7f0d-41d7-adad-425c9a344eb0", "name": "p1rdt7069lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "63c74f01-b8e6-49bc-8ad2-88e28191cae0"}}}}, {"uuid": "12d42c56-9b80-4486-a359-8e37f81f809d", "name": "", "x": 38.558729158203484, "y": -122.50556236696406, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "baccbdab-efc0-487d-b00d-38d3d4be57b4", "name": "p1rlv15045", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "12d42c56-9b80-4486-a359-8e37f81f809d"}}}}, {"uuid": "56999ec8-df70-47e8-a22e-684768da3d2c", "name": "", "x": 38.56237327512186, "y": -122.49906112727943, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "844bdc22-2e32-43ee-8e0b-26f3f4c107b8", "name": "p1rdt7070lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "56999ec8-df70-47e8-a22e-684768da3d2c"}}}}, {"uuid": "e3bc0fa3-6811-498e-a16c-8320d0a293f7", "name": "", "x": 38.5623473065519, "y": -122.49901854030558, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "366c9c98-59f1-46d5-b39c-4046703e5e4b", "name": "p1rlv15064", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e3bc0fa3-6811-498e-a16c-8320d0a293f7"}}}}, {"uuid": "a83cc9c4-4b11-4010-aa19-b53e73508459", "name": "", "x": 38.56125382119533, "y": -122.50733957591181, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0e0577c2-8275-4303-ad11-2c4f56df3f5c", "name": "p1rdt7075lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a83cc9c4-4b11-4010-aa19-b53e73508459"}}}}, {"uuid": "9a93678c-2745-43ef-87e0-0b312f04dcc6", "name": "", "x": 38.56131680649824, "y": -122.50731619031008, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a56b9ad8-c53b-4652-bf94-a7a7dfb8b306", "name": "p1rlv15082", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9a93678c-2745-43ef-87e0-0b312f04dcc6"}}}}, {"uuid": "5c7c788f-e292-4ed5-b8b6-2d92179a1549", "name": "", "x": 38.561391603460336, "y": -122.50795843776592, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d86bd7f-7759-4d74-9c74-d58010498f92", "name": "p1rdt7080lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5c7c788f-e292-4ed5-b8b6-2d92179a1549"}}}}, {"uuid": "67d11589-d890-4924-88d4-c67f869a6f93", "name": "", "x": 38.561343164924004, "y": -122.50782854332392, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "161d4e7b-30f2-447c-a369-1bfa3ba2cd70", "name": "p1rlv15109", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "67d11589-d890-4924-88d4-c67f869a6f93"}}}}, {"uuid": "95c151ef-ad3e-4f24-a147-4c639e3a18d2", "name": "", "x": 38.56161341947106, "y": -122.5078037444857, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bb6d8f13-f04e-4b80-a8dc-e16af1dc860e", "name": "p1rlv15125", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "95c151ef-ad3e-4f24-a147-4c639e3a18d2"}}}}, {"uuid": "4b3c05ad-cedd-477b-93ed-febea5d5232f", "name": "", "x": 38.559858339047835, "y": -122.50687058401597, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d0c96fe-78c2-4303-ac5c-bbe440f19666", "name": "p1rdt7087lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4b3c05ad-cedd-477b-93ed-febea5d5232f"}}}}, {"uuid": "db357bf8-bd4f-49eb-b3b1-04933eed13f3", "name": "", "x": 38.56006676468359, "y": -122.5064714121144, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bdee6d84-9253-4fba-b713-3e41d706e999", "name": "p1rlv15163", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "db357bf8-bd4f-49eb-b3b1-04933eed13f3"}}}}, {"uuid": "7c2faef8-a10d-4e28-bc4d-8542fee740d0", "name": "", "x": 38.55723982473556, "y": -122.5059256790796, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0f1652e8-6cf7-43d4-8474-e61a74873675", "name": "p1rdt7088lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7c2faef8-a10d-4e28-bc4d-8542fee740d0"}}}}, {"uuid": "5715e666-b8a9-484f-ba5f-8126a94010c7", "name": "", "x": 38.55722600645399, "y": -122.50597665691777, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2d2f8fcb-c279-49d5-88be-39e6a1d1990b", "name": "p1rlv15170", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5715e666-b8a9-484f-ba5f-8126a94010c7"}}}}, {"uuid": "0b91e779-c081-46eb-ba57-0400b5966cb1", "name": "", "x": 38.55763186186392, "y": -122.50515401038457, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "73cfcce9-a925-4f29-9cde-6dd6f50735e1", "name": "p1rdt7089lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0b91e779-c081-46eb-ba57-0400b5966cb1"}}}}, {"uuid": "7645a840-49f1-4f3d-bf88-0d557ff10242", "name": "", "x": 38.5576058954936, "y": -122.50511142397353, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dc7cd505-823c-49bb-9e49-3681267dbef0", "name": "p1rlv15171", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7645a840-49f1-4f3d-bf88-0d557ff10242"}}}}, {"uuid": "1846601f-ea73-4a6d-b41f-f06723617295", "name": "", "x": 38.55819291339373, "y": -122.50729514639205, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5d6a4c80-d261-4350-8224-8fe5191459c7", "name": "p1rdt7090lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1846601f-ea73-4a6d-b41f-f06723617295"}}}}, {"uuid": "5f1f5eaa-fca2-4063-8623-d2c87240ac98", "name": "", "x": 38.558186799297566, "y": -122.50731063399988, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e218b01d-f713-4baf-9688-7e77ea413c8c", "name": "p1rlv15180", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5f1f5eaa-fca2-4063-8623-d2c87240ac98"}}}}, {"uuid": "d41eed58-eb05-4eb6-91b8-26ead7b42739", "name": "", "x": 38.643254518897194, "y": -122.45483995487372, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6718b871-3967-4c29-83e5-441799c7fb92", "name": "p1rdt7201lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d41eed58-eb05-4eb6-91b8-26ead7b42739"}}}}, {"uuid": "b9bae9e3-62cb-4c3b-a8b7-2fdb6158be87", "name": "", "x": 38.64314352984028, "y": -122.45483682254313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fd21ae8b-7841-43b4-871f-316c4b8b4cd2", "name": "p1rlv15394", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b9bae9e3-62cb-4c3b-a8b7-2fdb6158be87"}}}}, {"uuid": "8c6660ec-b375-4cc2-8f0d-b4269bbad1e5", "name": "", "x": 38.64359496143701, "y": -122.45501725670924, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5ec1f313-f341-498c-b1c2-6669b1cbc629", "name": "p1rlv15399", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8c6660ec-b375-4cc2-8f0d-b4269bbad1e5"}}}}, {"uuid": "862f0625-04be-4c1c-9407-0449f1b4e76d", "name": "", "x": 38.643369459814934, "y": -122.45497300119509, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8bc46399-0276-4ae7-aa8b-4cdd3d3555e8", "name": "p1rlv15419", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "862f0625-04be-4c1c-9407-0449f1b4e76d"}}}}, {"uuid": "6d0c0017-941d-496d-a360-3f767288ac7d", "name": "", "x": 38.643190246717545, "y": -122.45519268460242, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "335df4da-50d2-4fbe-a271-ac04257d35c7", "name": "p1rlv15478", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6d0c0017-941d-496d-a360-3f767288ac7d"}}}}, {"uuid": "f9f10379-c1aa-4451-908d-38eecfa2b445", "name": "", "x": 38.6429090279938, "y": -122.45418759719459, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "37ccfa64-1373-49b2-85f6-279abea3c945", "name": "p1rlv15523", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f9f10379-c1aa-4451-908d-38eecfa2b445"}}}}, {"uuid": "f75bd794-6d16-46ee-99bd-adaf4993874e", "name": "", "x": 38.64844611776415, "y": -122.46453889053006, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5d5e45d6-867a-4442-8258-2c04891dbc4b", "name": "p1rdt7220lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f75bd794-6d16-46ee-99bd-adaf4993874e"}}}}, {"uuid": "16ccf6c7-32c1-4714-b004-edbd0fcf2460", "name": "", "x": 38.64842013673824, "y": -122.46449626559803, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f9ca373a-b1c3-464d-bbe3-c05b728beb30", "name": "p1rlv15418", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "16ccf6c7-32c1-4714-b004-edbd0fcf2460"}}}}, {"uuid": "6226913c-7d7d-477d-95e9-54bb8abd2648", "name": "", "x": 38.64544505846416, "y": -122.42121162161781, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d6a6156f-e72a-41f0-a307-e6030de24fde", "name": "p1rdt7224lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6226913c-7d7d-477d-95e9-54bb8abd2648"}}}}, {"uuid": "27cb7911-2e9b-464c-93c0-ac632f6ff630", "name": "", "x": 38.64521777279914, "y": -122.42138184387917, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "921f8f54-ff83-4d2f-8bf4-ee80bab64ce8", "name": "p1rlv15487", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "27cb7911-2e9b-464c-93c0-ac632f6ff630"}}}}, {"uuid": "69b27ea4-60b0-4eda-81a3-4486c128089b", "name": "", "x": 38.64535123894055, "y": -122.42103603545684, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "79c5341b-3cd2-41a3-8bbf-e50857b00dae", "name": "p1rdm15891", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "69b27ea4-60b0-4eda-81a3-4486c128089b"}}}}, {"uuid": "09527da2-781f-41bf-b313-d35ece88a326", "name": "", "x": 38.64513570345144, "y": -122.42118715458822, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "26009a7e-9bfc-4967-af28-4d8937539eb1", "name": "p1rlv15423", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "09527da2-781f-41bf-b313-d35ece88a326"}}}}, {"uuid": "bb839b26-b6d1-4449-a1b9-452e490d2a89", "name": "", "x": 38.64529779575312, "y": -122.42116286827518, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "34e0ffc2-da17-441b-bd4d-26d5a1104712", "name": "p1rlv15474", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bb839b26-b6d1-4449-a1b9-452e490d2a89"}}}}, {"uuid": "a328fc38-9751-4e00-9895-2603399f0135", "name": "", "x": 38.648428944357136, "y": -122.46102923499245, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2087cee5-9f6e-4400-8ca8-bbb120cd4dae", "name": "p1rdt7248lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a328fc38-9751-4e00-9895-2603399f0135"}}}}, {"uuid": "750db3fa-bb1a-4d04-b712-ff839caf5bfb", "name": "", "x": 38.64843531677844, "y": -122.46107118044478, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "544be417-0db6-45a7-8314-ec40944781fa", "name": "p1rlv15466", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "750db3fa-bb1a-4d04-b712-ff839caf5bfb"}}}}, {"uuid": "862f5d4c-08c7-48f1-a229-70ced1db006d", "name": "", "x": 38.648497708978724, "y": -122.4609213210892, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3c4e3eac-0b1a-4feb-b39f-079c6d2c1d82", "name": "p1rlv15483", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "862f5d4c-08c7-48f1-a229-70ced1db006d"}}}}, {"uuid": "32bfc63e-f0fa-4281-8265-4295041aa664", "name": "", "x": 38.64803011681224, "y": -122.46114316554923, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6579cc93-2b08-4010-816d-3bef509000cd", "name": "p1rlv15488", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "32bfc63e-f0fa-4281-8265-4295041aa664"}}}}, {"uuid": "6a9646be-d91a-42e6-b44c-c57056f16ac4", "name": "", "x": 38.64867815080695, "y": -122.46096593584461, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b09822b3-a220-48ff-ad4f-62fca602f8b6", "name": "p1rlv15542", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a9646be-d91a-42e6-b44c-c57056f16ac4"}}}}, {"uuid": "009068dc-1050-4ede-85b3-38c88606ebaa", "name": "", "x": 38.64806971694897, "y": -122.4591176468453, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b4f7df4-5453-459d-8599-48fd5f29a9c6", "name": "p1rdt7253lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "009068dc-1050-4ede-85b3-38c88606ebaa"}}}}, {"uuid": "4f4045d5-a424-4828-8712-a5e2d27af07c", "name": "", "x": 38.6480437339618, "y": -122.45907502411583, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6749066f-4739-41ec-8369-8da49dd9e1c8", "name": "p1rlv15484", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4f4045d5-a424-4828-8712-a5e2d27af07c"}}}}, {"uuid": "ce488c5f-6b15-495e-a1dc-3e08aea6376a", "name": "", "x": 38.650849807011845, "y": -122.4260111114199, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1130272e-b98e-496f-aeb9-c094cf9cd824", "name": "p1rdt7268lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ce488c5f-6b15-495e-a1dc-3e08aea6376a"}}}}, {"uuid": "6a086fd3-e4a3-4194-82d1-3d55ac26d4a6", "name": "", "x": 38.650823812052785, "y": -122.42596849916298, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6eec860d-08cf-4690-93e6-d909429d363d", "name": "p1rlv15525", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a086fd3-e4a3-4194-82d1-3d55ac26d4a6"}}}}, {"uuid": "654a9de7-dcb0-4746-8171-280e65546dae", "name": "", "x": 38.56642393843708, "y": -122.500066081999, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d304e5e0-2cc1-4167-9fad-6fc72228d828", "name": "p1rdt7298lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "654a9de7-dcb0-4746-8171-280e65546dae"}}}}, {"uuid": "6a642350-2238-4a5c-825f-8e833548e191", "name": "", "x": 38.56639797023211, "y": -122.50002349228465, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "688da57a-6f10-4ef8-8763-202a88c3a495", "name": "p1rlv15603", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a642350-2238-4a5c-825f-8e833548e191"}}}}, {"uuid": "81704916-b78c-4299-8fc1-4958e3705545", "name": "", "x": 38.586910904171326, "y": -122.52012069769289, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "43df4c14-a198-4d51-87f4-80000198cd47", "name": "p1rdt7301lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "81704916-b78c-4299-8fc1-4958e3705545"}}}}, {"uuid": "9fcd0830-ea92-460e-88c4-2f39c88f4ed7", "name": "", "x": 38.58688494322849, "y": -122.52007808865979, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c32ce070-e690-4fc1-92ac-f857691de578", "name": "p1rlv15606", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9fcd0830-ea92-460e-88c4-2f39c88f4ed7"}}}}, {"uuid": "a00d66f5-e5d7-4a85-b1e2-41d52b447303", "name": "", "x": 38.56306853879527, "y": -122.5102770561152, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3e2a141f-436a-45c0-9c15-179301a439c8", "name": "p1rdt7302lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a00d66f5-e5d7-4a85-b1e2-41d52b447303"}}}}, {"uuid": "aa80928f-e27e-42d3-ab52-19e97aa61d61", "name": "", "x": 38.56308491307865, "y": -122.51055992850522, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32291502-d7be-4b45-8af7-cb217448e73f", "name": "p1rlv15607", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aa80928f-e27e-42d3-ab52-19e97aa61d61"}}}}, {"uuid": "cd52fc3f-b014-47cf-820c-b191189ba802", "name": "", "x": 38.563191661348114, "y": -122.51022633928095, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2715a637-d6f0-4e7b-b43e-20836bf4e614", "name": "p1rlv15638", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cd52fc3f-b014-47cf-820c-b191189ba802"}}}}, {"uuid": "62d95444-7296-4d3a-8cb0-3fa5dd858b1b", "name": "", "x": 38.56290700610434, "y": -122.51179679741092, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0926064a-1c87-450a-b282-23708de8aec4", "name": "p1rdt7306lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "62d95444-7296-4d3a-8cb0-3fa5dd858b1b"}}}}, {"uuid": "bf198d6d-a6e0-4737-a4e7-8a2939338d8d", "name": "", "x": 38.56368313784799, "y": -122.511382300603, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5ab2d6dc-f5bb-4320-86f3-bf08bb7cf93f", "name": "p1rlv15614", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bf198d6d-a6e0-4737-a4e7-8a2939338d8d"}}}}, {"uuid": "5fea1be8-832e-410d-af35-560129d549bc", "name": "", "x": 38.57387166576081, "y": -122.5068092396372, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6ce9dd2c-9e17-46b7-a6f4-e85077664432", "name": "p1rdt7307lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5fea1be8-832e-410d-af35-560129d549bc"}}}}, {"uuid": "e984cc18-d43d-4279-98ad-7a297ad808c9", "name": "", "x": 38.573802276520816, "y": -122.50677924408086, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6106bbe7-7a47-4c50-8b2a-d46d7432bccf", "name": "p1rlv15617", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e984cc18-d43d-4279-98ad-7a297ad808c9"}}}}, {"uuid": "60d115bb-a2f5-47fd-ad21-f774776aafdc", "name": "", "x": 38.573945931269776, "y": -122.50665198381543, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0bb184ad-cb26-4317-8c40-f2c8a9f80dab", "name": "p1rlv19146", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "60d115bb-a2f5-47fd-ad21-f774776aafdc"}}}}, {"uuid": "6243e000-7c2a-4199-aba2-ca01fe1b1dd7", "name": "", "x": 38.57392039558398, "y": -122.50700803276428, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "546433b3-d70e-49ed-9037-ec88adda79b9", "name": "p1rlv19147", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6243e000-7c2a-4199-aba2-ca01fe1b1dd7"}}}}, {"uuid": "1df6c2be-0b95-47ed-8ccf-650263d8acdb", "name": "", "x": 38.563303651285544, "y": -122.5126284769322, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e2d6046b-9ece-4295-a180-41bf2ce47ce6", "name": "p1rdt7311lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1df6c2be-0b95-47ed-8ccf-650263d8acdb"}}}}, {"uuid": "daba764b-a0fc-4c47-b9d1-f41023553bb6", "name": "", "x": 38.56384855592281, "y": -122.51215022095688, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1151b559-3ae0-4863-9363-9b395bbfc403", "name": "p1rlv15622", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "daba764b-a0fc-4c47-b9d1-f41023553bb6"}}}}, {"uuid": "1f14723b-86dc-4a46-a672-3ed1ff4b6072", "name": "", "x": 38.56815134225955, "y": -122.50546068410047, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "97844fdb-b016-4ca3-8777-b0553ead9297", "name": "p1rdt7314lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1f14723b-86dc-4a46-a672-3ed1ff4b6072"}}}}, {"uuid": "ea07bd82-2337-41b7-ac6c-4158f09b55a2", "name": "", "x": 38.56817687324023, "y": -122.50541766691859, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ec0bca53-a58b-4004-8dba-8defca9db4c7", "name": "p1rlv15629", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea07bd82-2337-41b7-ac6c-4158f09b55a2"}}}}, {"uuid": "502ec234-aaf7-4749-8910-9336c0c13d45", "name": "", "x": 38.56855471658057, "y": -122.50523980787194, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "22b1ecce-d5df-4f42-abb2-9f4c3d3a28c5", "name": "p1rdt7318lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "502ec234-aaf7-4749-8910-9336c0c13d45"}}}}, {"uuid": "7ae0df86-6d12-44d0-9fd4-967a2abacbfa", "name": "", "x": 38.568569050828, "y": -122.50529056187261, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a5af6dae-d20f-4a31-9544-b9455cd639bd", "name": "p1rlv15634", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7ae0df86-6d12-44d0-9fd4-967a2abacbfa"}}}}, {"uuid": "c125e674-85b7-4f60-93b0-24e4722e6cc3", "name": "", "x": 38.60115277629168, "y": -122.46102699453549, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "58be5cbe-5a7c-4fa5-972d-e03100b3bb46", "name": "p1rdt7550lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c125e674-85b7-4f60-93b0-24e4722e6cc3"}}}}, {"uuid": "d96464bf-d57f-4a79-95ab-73e600c00eb4", "name": "", "x": 38.60105048076314, "y": -122.46095488399553, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5984e209-9f0e-4844-91e6-902c8329f13c", "name": "p1rlv16114", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d96464bf-d57f-4a79-95ab-73e600c00eb4"}}}}, {"uuid": "f04f0ccb-57e8-461b-80fb-4acde4ab77df", "name": "", "x": 38.60120431220644, "y": -122.46109154303083, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "807b0bef-0d34-44a9-a2a9-0c0a11f4ea8e", "name": "p1rlv16178", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f04f0ccb-57e8-461b-80fb-4acde4ab77df"}}}}, {"uuid": "6b7c2c76-7774-48ee-910e-81eb26d11585", "name": "", "x": 38.60318695205525, "y": -122.45853113684389, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1c4d7ee3-fc5d-4a17-a717-3d6b6d5a67ae", "name": "p1rdt7551lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6b7c2c76-7774-48ee-910e-81eb26d11585"}}}}, {"uuid": "6cf6c48f-0c39-4e82-aaa5-9850a4ea3d6c", "name": "", "x": 38.6034004318743, "y": -122.45853704613184, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "52d1b79d-5c6b-4b44-9998-600c6debd999", "name": "p1rlv16115", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6cf6c48f-0c39-4e82-aaa5-9850a4ea3d6c"}}}}, {"uuid": "ce389c53-ae3e-4477-bd2e-926434e7d3c2", "name": "", "x": 38.60293177722496, "y": -122.45852908328547, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6efff4f7-c67b-4cfb-a72d-30b6616825b1", "name": "p1rlv16157", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ce389c53-ae3e-4477-bd2e-926434e7d3c2"}}}}, {"uuid": "86be8abe-cfa1-408c-9fae-445d6897801f", "name": "", "x": 38.601851120199065, "y": -122.45542100224573, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1f5d6708-cef4-4aac-9fa0-c738953c788f", "name": "p1rdt7552lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "86be8abe-cfa1-408c-9fae-445d6897801f"}}}}, {"uuid": "7d645f59-ab39-476e-b903-ae66856dfb97", "name": "", "x": 38.60199783561238, "y": -122.45535495885304, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "972f8088-b67b-47d0-a86f-49179dfb1c92", "name": "p1rlv16116", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7d645f59-ab39-476e-b903-ae66856dfb97"}}}}, {"uuid": "5306fedc-377c-405e-8294-70ab141da9c9", "name": "", "x": 38.60173719494335, "y": -122.45550622371668, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "92a37082-36d4-4eca-95e4-88dbcacd6db5", "name": "p1rlv16197", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5306fedc-377c-405e-8294-70ab141da9c9"}}}}, {"uuid": "2f0e73df-0c62-40a8-a734-286365ac0370", "name": "", "x": 38.60639320900444, "y": -122.45582291610495, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e7a672b2-d127-4fb5-8cc4-8115b8ef3f60", "name": "p1rdt7553lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2f0e73df-0c62-40a8-a734-286365ac0370"}}}}, {"uuid": "9c579c2e-db54-4d6b-906e-b3e3396c2a73", "name": "", "x": 38.606405183855294, "y": -122.45547094869913, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "204899ec-81e4-4a72-bf70-69b3428a49a1", "name": "p1rlv16117", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9c579c2e-db54-4d6b-906e-b3e3396c2a73"}}}}, {"uuid": "2bf36cf3-92b0-4202-afe5-e4a82e38ea10", "name": "", "x": 38.60746648825486, "y": -122.45829224306911, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "86a6d184-d883-4e27-aee5-b89c82163284", "name": "p1rdt7554lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2bf36cf3-92b0-4202-afe5-e4a82e38ea10"}}}}, {"uuid": "2df0eb30-a882-4def-ab77-29e11f4fd85d", "name": "", "x": 38.60753796176142, "y": -122.45877011077201, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bca0b3a0-d4cb-4a4a-9b14-aa23d9e5e5fe", "name": "p1rlv16118", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2df0eb30-a882-4def-ab77-29e11f4fd85d"}}}}, {"uuid": "c4771003-2c0d-47fc-bf08-901d4c211e51", "name": "", "x": 38.60761943761314, "y": -122.45884989486198, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c840cf3f-be15-448b-8c03-8942c586b135", "name": "p1rlv16139", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c4771003-2c0d-47fc-bf08-901d4c211e51"}}}}, {"uuid": "14b6738b-41dd-4f20-ab31-7fd70218af0b", "name": "", "x": 38.60732511225313, "y": -122.45756577239354, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "68aa5cc5-f6bf-4417-8653-747c56b37b5e", "name": "p1rlv16201", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "14b6738b-41dd-4f20-ab31-7fd70218af0b"}}}}, {"uuid": "0b85b1e3-d355-43b8-8b7a-6468a77acd10", "name": "", "x": 38.60729988695483, "y": -122.45795645616205, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf413742-18c8-483d-b8f1-f125f95323da", "name": "p1rlv16209", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0b85b1e3-d355-43b8-8b7a-6468a77acd10"}}}}, {"uuid": "988e9a2d-9ed8-4c63-b121-042df9ce3188", "name": "", "x": 38.599910107670105, "y": -122.4605115694972, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0de9c581-b78b-44d6-8693-59b995e2a3bb", "name": "p1rdt7555lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "988e9a2d-9ed8-4c63-b121-042df9ce3188"}}}}, {"uuid": "53064509-7052-4af7-87fe-e13f6ad6d921", "name": "", "x": 38.60005645544839, "y": -122.46036515331646, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c0d6e608-d5bf-40d6-9efd-f3b0922e7d77", "name": "p1rlv16119", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "53064509-7052-4af7-87fe-e13f6ad6d921"}}}}, {"uuid": "7829fac3-fe6e-4708-aebe-204569ca6f84", "name": "", "x": 38.607794956621454, "y": -122.45548336703727, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0b593ec6-e1e3-48c2-b352-f7966f206aa9", "name": "p1rdt7559lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7829fac3-fe6e-4708-aebe-204569ca6f84"}}}}, {"uuid": "84d7a033-8e7b-4fb0-9cc0-c8644b232b05", "name": "", "x": 38.60770977446864, "y": -122.45501316679001, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6da4b2d0-66c7-43fb-9aab-3bbac03aa989", "name": "p1rlv16124", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "84d7a033-8e7b-4fb0-9cc0-c8644b232b05"}}}}, {"uuid": "cb0b839a-cd6f-491d-932b-83f7ff4c8736", "name": "", "x": 38.60025024332015, "y": -122.46073516079042, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "05e30abd-3c40-4dbd-9261-ca8a8abd9c56", "name": "p1rdt7561lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb0b839a-cd6f-491d-932b-83f7ff4c8736"}}}}, {"uuid": "e788a403-3ee0-4bc1-83e8-447ea9a8a20a", "name": "", "x": 38.60030209684127, "y": -122.46086860989422, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bd41f55a-4b5d-4c19-9787-801072b3b946", "name": "p1rlv16126", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e788a403-3ee0-4bc1-83e8-447ea9a8a20a"}}}}, {"uuid": "4124fd29-4733-49fc-a471-b50ad153de68", "name": "", "x": 38.60042704179853, "y": -122.46060354272663, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "102b9460-ea9a-4099-b16f-40b8fdf99ef7", "name": "p1rlv16133", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4124fd29-4733-49fc-a471-b50ad153de68"}}}}, {"uuid": "0d6f3592-9121-45e3-9cbe-84457185ba70", "name": "", "x": 38.60180967142113, "y": -122.46424249788332, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f7588b3b-f54c-483d-b354-b9908483019a", "name": "p1rdt7564lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0d6f3592-9121-45e3-9cbe-84457185ba70"}}}}, {"uuid": "8dec918d-10ab-432a-b8bb-e415a12f101b", "name": "", "x": 38.60183518685866, "y": -122.46419944605898, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "676de1a3-2dfd-4faa-a057-7739e825d136", "name": "p1rlv16135", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8dec918d-10ab-432a-b8bb-e415a12f101b"}}}}, {"uuid": "31d60c7f-e3f0-4686-8e19-b56bd4e1464a", "name": "", "x": 38.6078075576706, "y": -122.45772713266135, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f2b3b9e1-3d98-44c1-bd38-9325623a1553", "name": "p1rdt7570lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "31d60c7f-e3f0-4686-8e19-b56bd4e1464a"}}}}, {"uuid": "fa7474fe-414e-4687-8d13-9b47b7f5bf2e", "name": "", "x": 38.60779838775444, "y": -122.45777980644779, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6d21c357-1033-45e1-84a0-b82ceafe6ab8", "name": "p1rlv16146", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa7474fe-414e-4687-8d13-9b47b7f5bf2e"}}}}, {"uuid": "14c8ea02-6b8a-4683-a209-b207e62df26b", "name": "", "x": 38.60626762047214, "y": -122.45581795786703, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "69bf048e-54cd-4e41-a23e-485b0cd98fae", "name": "p1rdt7572lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "14c8ea02-6b8a-4683-a209-b207e62df26b"}}}}, {"uuid": "2814eb4a-ef43-4726-81b5-35cb10bb963a", "name": "", "x": 38.60645647275145, "y": -122.45487334223284, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b15792ca-a6bd-47e5-8c67-5c3076174848", "name": "p1rlv16149", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2814eb4a-ef43-4726-81b5-35cb10bb963a"}}}}, {"uuid": "84a70399-13e1-4ea7-b2cd-5a587410bf53", "name": "", "x": 38.60650078143132, "y": -122.45471221720932, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1aacea55-115d-46c3-9590-725cf5040f38", "name": "p1rlv16200", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "84a70399-13e1-4ea7-b2cd-5a587410bf53"}}}}, {"uuid": "644491c8-32e3-415d-a8b2-9cdc7acd7dfa", "name": "", "x": 38.606181337381166, "y": -122.4557827336667, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33a848c7-076e-4025-863b-ce9151bcc3ac", "name": "p1rdm16630", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "644491c8-32e3-415d-a8b2-9cdc7acd7dfa"}}}}, {"uuid": "1cd42c9f-87d5-443d-bc3d-baf635075a0e", "name": "", "x": 38.60633132723502, "y": -122.45509250327417, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b85e180a-8eb4-4acc-a816-d99758cc16ea", "name": "p1rlv16158", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1cd42c9f-87d5-443d-bc3d-baf635075a0e"}}}}, {"uuid": "756f2ab1-9338-45a3-9e5c-bf0de418e671", "name": "", "x": 38.60650742609989, "y": -122.45740736442846, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a742708-0f8b-42d0-a977-b5ce5e36a042", "name": "p1rdt7574lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "756f2ab1-9338-45a3-9e5c-bf0de418e671"}}}}, {"uuid": "b72df13b-b760-4f9c-8e84-7384a4026df1", "name": "", "x": 38.606502198240534, "y": -122.45735394894129, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "74edd9e9-24a5-4b36-8ca8-24ef2fa3e972", "name": "p1rlv16156", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b72df13b-b760-4f9c-8e84-7384a4026df1"}}}}, {"uuid": "bd429532-7ff5-4e19-8118-d02b72b2445d", "name": "", "x": 38.59916576086806, "y": -122.46399319639457, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "56b05024-7907-458d-a5c3-0e54ffbabdb5", "name": "p1rdt7576lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bd429532-7ff5-4e19-8118-d02b72b2445d"}}}}, {"uuid": "7198a865-1cfe-44a8-8fab-751b1cc8a6af", "name": "", "x": 38.59972953494432, "y": -122.46374387036614, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4fb5abb7-dd79-49aa-9185-88a90bb45bc7", "name": "p1rlv16168", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7198a865-1cfe-44a8-8fab-751b1cc8a6af"}}}}, {"uuid": "89474c6b-5738-4943-9265-a4fb35b3a0a5", "name": "", "x": 38.603712525417045, "y": -122.46283870922412, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4d00b7fe-0384-4c12-a0cf-8895458d3b80", "name": "p1rdt7579lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "89474c6b-5738-4943-9265-a4fb35b3a0a5"}}}}, {"uuid": "332633b6-3eb5-4d54-8439-cfecf21faba5", "name": "", "x": 38.60368654376888, "y": -122.46279611119927, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cbbe8401-53a1-4ce7-9ce1-02f547055d95", "name": "p1rlv16177", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "332633b6-3eb5-4d54-8439-cfecf21faba5"}}}}, {"uuid": "e75397fa-6344-480e-8b24-b7e3fb47e90b", "name": "", "x": 38.601513560330964, "y": -122.46255652294417, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "abc940b0-c9f5-4582-adaf-ad7f4a79a35f", "name": "p1rdt7588lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e75397fa-6344-480e-8b24-b7e3fb47e90b"}}}}, {"uuid": "1dbfb486-355e-48bb-9547-1c5af9aab2e8", "name": "", "x": 38.601499761325734, "y": -122.46260754027634, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0ca42395-8d67-4e83-80ec-159cacb490f8", "name": "p1rlv16206", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1dbfb486-355e-48bb-9547-1c5af9aab2e8"}}}}, {"uuid": "f01e60a2-6edb-4fa2-90ef-fa24804682ad", "name": "", "x": 38.63266298601826, "y": -122.4216856102529, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "53e9cf92-1c91-428f-bdff-64257257ad5b", "name": "p1rdt7589lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f01e60a2-6edb-4fa2-90ef-fa24804682ad"}}}}, {"uuid": "4e04d8fd-20ec-4f89-8bbf-cf16549031aa", "name": "", "x": 38.632738611285475, "y": -122.42182684518295, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9fd05f3c-df77-45bc-8686-458b681a3d08", "name": "p1rlv16210", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4e04d8fd-20ec-4f89-8bbf-cf16549031aa"}}}}, {"uuid": "6dea6e95-aba5-4fce-b04c-34f7c28df0ab", "name": "", "x": 38.63262911078122, "y": -122.4215519854009, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "56b91b3f-dfdd-41bf-9d2e-a8183077c752", "name": "p1rlv16235", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6dea6e95-aba5-4fce-b04c-34f7c28df0ab"}}}}, {"uuid": "226e95df-79cb-49c6-99eb-7ce9f9be1eda", "name": "", "x": 38.63109043622211, "y": -122.42673165565434, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ff1e0d26-d845-43c3-9aaf-01d1c007b9a1", "name": "p1rdt7598lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "226e95df-79cb-49c6-99eb-7ce9f9be1eda"}}}}, {"uuid": "a34d4271-e724-4b08-9a1e-9e75013aa774", "name": "", "x": 38.631104804579536, "y": -122.42678243753235, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b9761003-33fa-482a-967b-b508ab67c19f", "name": "p1rlv16221", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a34d4271-e724-4b08-9a1e-9e75013aa774"}}}}, {"uuid": "7115795f-d38c-435c-bd32-d79fd0c3e2be", "name": "", "x": 38.59926349646212, "y": -122.48320976110043, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d838502-3769-4d70-839b-26fd628ce478", "name": "p1rdt7599lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7115795f-d38c-435c-bd32-d79fd0c3e2be"}}}}, {"uuid": "c3f465b9-0d5a-4166-b70d-0b31c3a84cab", "name": "", "x": 38.59924968840877, "y": -122.4832607729825, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4809afc1-2d3d-491d-80e5-9cd4e8da08f2", "name": "p1rlv16222", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c3f465b9-0d5a-4166-b70d-0b31c3a84cab"}}}}, {"uuid": "7e356edd-9a1e-4a20-b1e2-05ff729a0ab9", "name": "", "x": 38.63045512607571, "y": -122.42581761149648, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d3488ff0-696f-4180-bc70-41ff37f9c365", "name": "p1rdt7605lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7e356edd-9a1e-4a20-b1e2-05ff729a0ab9"}}}}, {"uuid": "dba9df17-dbb7-40e0-8389-32f86a83d0ce", "name": "", "x": 38.63042913104939, "y": -122.4257750112935, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b8767650-39c5-4d4a-80ce-af408c246599", "name": "p1rlv16228", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dba9df17-dbb7-40e0-8389-32f86a83d0ce"}}}}, {"uuid": "ba3209f3-ddc3-42d2-9fb6-73352cdcc890", "name": "", "x": 38.62802329409922, "y": -122.420609783299, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0fdfea70-187a-4bbc-ba3f-69cb74c4d5c5", "name": "p1rdt7612lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ba3209f3-ddc3-42d2-9fb6-73352cdcc890"}}}}, {"uuid": "f517027f-3138-4efe-b5c1-6b209dd16b66", "name": "", "x": 38.62799729719169, "y": -122.42056718642846, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9642fa30-e5f7-42f1-8fda-ab75a265d25a", "name": "p1rlv16239", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f517027f-3138-4efe-b5c1-6b209dd16b66"}}}}, {"uuid": "eae6de67-8927-41f1-b2b4-566cb14958c4", "name": "", "x": 38.56073046128886, "y": -122.50852889395006, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "269e9ba5-bc54-4cbd-9140-4b1bea74fc53", "name": "p1rdt7615lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eae6de67-8927-41f1-b2b4-566cb14958c4"}}}}, {"uuid": "dfa27b4c-8f60-4a6f-8e32-e240e90c01fa", "name": "", "x": 38.56046440447144, "y": -122.50887900476087, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e82036d9-e6c8-42c3-b45b-30bef6902bbc", "name": "p1rlv16242", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dfa27b4c-8f60-4a6f-8e32-e240e90c01fa"}}}}, {"uuid": "6ee0bd86-1680-444a-a29c-1dc0ca96d7f2", "name": "", "x": 38.56073966572795, "y": -122.50857474214654, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "978533ca-ef57-4cb6-9e7f-b3c6d1bbd7d5", "name": "p1rlv16261", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6ee0bd86-1680-444a-a29c-1dc0ca96d7f2"}}}}, {"uuid": "47348236-35ea-4e14-9db4-04f53ff4cb88", "name": "", "x": 38.562034810135316, "y": -122.51158858609705, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "65458dd3-50e0-48d3-a0db-0015707d3cea", "name": "p1rdm16694", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "47348236-35ea-4e14-9db4-04f53ff4cb88"}}}}, {"uuid": "51f24211-6a02-4069-9407-7162a0e828bf", "name": "", "x": 38.56202613361287, "y": -122.51166899029859, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "268549c6-0c8b-44ac-b933-316b36645366", "name": "p1rlv16253", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "51f24211-6a02-4069-9407-7162a0e828bf"}}}}, {"uuid": "84b11cd9-6ad0-4a24-a958-715b6fc7be35", "name": "", "x": 38.56186788179104, "y": -122.51113810898512, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6af13868-ecb1-4110-be3f-537741287035", "name": "p1rdt7616lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "84b11cd9-6ad0-4a24-a958-715b6fc7be35"}}}}, {"uuid": "7d5808cb-7939-481a-8de5-91a65946aa43", "name": "", "x": 38.56181598959075, "y": -122.51098173878029, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "83d31d7a-8900-4f2e-9183-8a10f07e2bdd", "name": "p1rdm16695", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7d5808cb-7939-481a-8de5-91a65946aa43"}}}}, {"uuid": "9e3cb4e1-00a3-40b7-a310-e1d3288381c9", "name": "", "x": 38.561797870283755, "y": -122.51095890578438, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c620d4b9-a849-4bf6-b108-118836866602", "name": "p1rlv16270", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9e3cb4e1-00a3-40b7-a310-e1d3288381c9"}}}}, {"uuid": "301d7474-7394-4adb-83c5-de8da079d030", "name": "", "x": 38.56163474835187, "y": -122.51074193179929, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "766647d4-7c3c-4058-b30c-dbc593b88ecb", "name": "p1rdm16693", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "301d7474-7394-4adb-83c5-de8da079d030"}}}}, {"uuid": "ee0e3777-b5c5-4c55-8a82-0a2aa0ec819c", "name": "", "x": 38.56165286770099, "y": -122.51076476468909, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "20818cc7-617e-4ab7-8f7c-31eea6496a02", "name": "p1rlv16243", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ee0e3777-b5c5-4c55-8a82-0a2aa0ec819c"}}}}, {"uuid": "effa99d5-0528-4214-9f65-c85da4d99cb0", "name": "", "x": 38.563138374369146, "y": -122.50973711139406, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4be4af94-fee7-40d6-9061-9a0fe0e7377e", "name": "p1rdt7617lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "effa99d5-0528-4214-9f65-c85da4d99cb0"}}}}, {"uuid": "daf01f10-6d6c-445b-9fdd-f5006c1c211b", "name": "", "x": 38.56309099533974, "y": -122.50985972349204, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e0164339-acc1-4b95-aa31-3af42cf943f7", "name": "p1rlv16244", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "daf01f10-6d6c-445b-9fdd-f5006c1c211b"}}}}, {"uuid": "53d2cce6-a3d7-4ce1-b40e-37e98b714398", "name": "", "x": 38.563135188623946, "y": -122.50965281749981, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4d1fb8eb-57aa-4366-afe5-b79174f3a4c7", "name": "p1rdm16697", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "53d2cce6-a3d7-4ce1-b40e-37e98b714398"}}}}, {"uuid": "767e8d01-6f03-4aab-bbdd-e7516fac9674", "name": "", "x": 38.563267563002256, "y": -122.50965942729142, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "04647fad-19dc-4ed8-8820-aa312674145c", "name": "p1rlv16255", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "767e8d01-6f03-4aab-bbdd-e7516fac9674"}}}}, {"uuid": "e6e642bd-5a02-4bab-9654-a8d16102dcd4", "name": "", "x": 38.64626899154278, "y": -122.41892573953396, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "795f4296-7c54-4e96-8468-52903af39708", "name": "p1rdm16699", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e6e642bd-5a02-4bab-9654-a8d16102dcd4"}}}}, {"uuid": "75f5fcc1-c81f-49ae-a4c9-1fe46bb70e41", "name": "", "x": 38.64646884092825, "y": -122.4192458831601, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5c6a5f39-0654-4e73-8050-c6c4ad9d54e6", "name": "p1rlv16252", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "75f5fcc1-c81f-49ae-a4c9-1fe46bb70e41"}}}}, {"uuid": "86e7ee95-7549-4c76-908c-030d93ec9795", "name": "", "x": 38.64614340209092, "y": -122.41904166679946, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "acb015a8-a9f8-492b-ab3f-b107bd956f91", "name": "p1rdm16698", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "86e7ee95-7549-4c76-908c-030d93ec9795"}}}}, {"uuid": "cb0a2f85-7a50-463d-bb48-789ac1c19a51", "name": "", "x": 38.646106728547146, "y": -122.41891555875277, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3783c838-b72e-42cd-8b0b-3005bca3cf5e", "name": "p1rlv16245", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb0a2f85-7a50-463d-bb48-789ac1c19a51"}}}}, {"uuid": "4a2288ec-9b7d-4dba-b1ba-c617235fedd4", "name": "", "x": 38.64641551310019, "y": -122.41882510751344, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "49f37435-54fc-42b4-baba-94f0611c8c76", "name": "p1rdt7618lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4a2288ec-9b7d-4dba-b1ba-c617235fedd4"}}}}, {"uuid": "25ca9092-333a-4071-952e-beb0df30161f", "name": "", "x": 38.64677146238617, "y": -122.41848500827774, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "73030a97-0574-4802-80d1-14fefeafa63a", "name": "p1rdm16700", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "25ca9092-333a-4071-952e-beb0df30161f"}}}}, {"uuid": "7a39814a-94fc-4129-9a0b-165f7813be33", "name": "", "x": 38.64669874248704, "y": -122.41835919083687, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "19aeb510-ac0e-4279-8db0-8de282beccc8", "name": "p1rlv16267", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7a39814a-94fc-4129-9a0b-165f7813be33"}}}}, {"uuid": "0630d605-bb3f-43f0-b776-d4ada20f11aa", "name": "", "x": 38.56141189302572, "y": -122.50849775727877, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3a205379-48f9-444c-baf8-dc84fc9c6d8a", "name": "p1rdt7619lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0630d605-bb3f-43f0-b776-d4ada20f11aa"}}}}, {"uuid": "15292442-11f0-4f4b-8858-9f1431a817b7", "name": "", "x": 38.561113439797154, "y": -122.50892049903847, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dd2dc2db-787a-4732-bae4-01186082a92d", "name": "p1rlv16246", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "15292442-11f0-4f4b-8858-9f1431a817b7"}}}}, {"uuid": "7388c6fa-ce1e-47ab-a43a-73bf44b2dacd", "name": "", "x": 38.56276173762939, "y": -122.51370313533468, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9af91c50-929d-4ac6-9272-7c44d17a0094", "name": "p1rdt7620lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7388c6fa-ce1e-47ab-a43a-73bf44b2dacd"}}}}, {"uuid": "90982ae6-16f2-483c-944a-57039dcebb07", "name": "", "x": 38.56259236273701, "y": -122.5134672071745, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a8d5e9b7-dc95-41f9-8547-99d5e2eba874", "name": "p1rlv16247", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "90982ae6-16f2-483c-944a-57039dcebb07"}}}}, {"uuid": "5106ecc5-1a2f-41bc-b6c8-3ae15176b9e9", "name": "", "x": 38.56176044882826, "y": -122.50995307443512, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60f0bddf-6e4b-495c-a98d-f3940d69a5e9", "name": "p1rdt7621lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5106ecc5-1a2f-41bc-b6c8-3ae15176b9e9"}}}}, {"uuid": "97ebfd06-ca63-41d2-ae54-9e9c8da085a2", "name": "", "x": 38.561693460357375, "y": -122.50969704739022, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "feb24768-feab-40f0-acc3-0b2bb500133a", "name": "p1rlv16248", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "97ebfd06-ca63-41d2-ae54-9e9c8da085a2"}}}}, {"uuid": "5ced85f7-f461-4760-989d-da3f0b33b912", "name": "", "x": 38.63755744615242, "y": -122.465948154899, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e2075fb-9691-447e-9a73-f88649310bc1", "name": "p1rdt7624lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ced85f7-f461-4760-989d-da3f0b33b912"}}}}, {"uuid": "5bc50684-7a0d-436b-972b-fe999f8f51db", "name": "", "x": 38.63754827273094, "y": -122.46600084949326, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32a9302f-2d40-4c2a-bde9-e4039694fed7", "name": "p1rlv16256", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5bc50684-7a0d-436b-972b-fe999f8f51db"}}}}, {"uuid": "cbff86f3-b1ca-4bb9-b929-b7706ddb1140", "name": "", "x": 38.56312481406225, "y": -122.50942641108807, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a6b1e3b6-ce3a-4ad6-a046-6608530b2ec2", "name": "p1rdt7625lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cbff86f3-b1ca-4bb9-b929-b7706ddb1140"}}}}, {"uuid": "ca85a7fc-d2bf-4ae4-bde9-edd5d0c42655", "name": "", "x": 38.56379044489856, "y": -122.50902854183389, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "935c99a6-bef6-4417-872c-0685011c440c", "name": "p1rlv16257", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ca85a7fc-d2bf-4ae4-bde9-edd5d0c42655"}}}}, {"uuid": "9094241e-f572-4ca2-a2f7-73618f62dfb3", "name": "", "x": 38.5622508740622, "y": -122.51221444287553, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "56f8eed1-77ae-4d65-80aa-7ae148350333", "name": "p1rdt7626lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9094241e-f572-4ca2-a2f7-73618f62dfb3"}}}}, {"uuid": "40f7128c-ed34-4a06-8927-100507e5ed27", "name": "", "x": 38.562245476566225, "y": -122.51240209551142, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fdf35585-e2b3-4463-a6a8-acb352f25003", "name": "p1rlv16260", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "40f7128c-ed34-4a06-8927-100507e5ed27"}}}}, {"uuid": "6de641fa-7013-4aa1-9223-c0f5bcdcc02b", "name": "", "x": 38.56232619942912, "y": -122.51230972629801, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fc746539-662a-4fe4-8774-6ba2dc538118", "name": "p1rlv16269", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6de641fa-7013-4aa1-9223-c0f5bcdcc02b"}}}}, {"uuid": "00cd9384-7f49-423e-b329-029dcc4041a7", "name": "", "x": 38.56258212321864, "y": -122.51385355991457, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "90d8891c-6e6d-46b9-8f88-acc9453c6541", "name": "p1rdt7627lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "00cd9384-7f49-423e-b329-029dcc4041a7"}}}}, {"uuid": "124e10ea-1bf0-41b7-a040-a7913288ddea", "name": "", "x": 38.562602805051284, "y": -122.51381147731462, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2797febc-f5e7-4cb3-b26f-ace990dc6920", "name": "p1rlv16262", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "124e10ea-1bf0-41b7-a040-a7913288ddea"}}}}, {"uuid": "e8a8f728-47d8-4295-b6f3-42e071ca524f", "name": "", "x": 38.56133819555369, "y": -122.51026584276248, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ad2599f-313b-49c6-abaa-19177e1a9edc", "name": "p1rdt7630lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e8a8f728-47d8-4295-b6f3-42e071ca524f"}}}}, {"uuid": "6fb5ec76-7803-4c02-9ae4-bb649280dfc2", "name": "", "x": 38.56092456814972, "y": -122.50968682475795, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e8835446-b333-4be9-96bd-57ff9d01ebd3", "name": "p1rlv16266", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6fb5ec76-7803-4c02-9ae4-bb649280dfc2"}}}}, {"uuid": "86853692-b205-4618-a7a5-8176c8cb9876", "name": "", "x": 38.5616967364387, "y": -122.50900438404291, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4861056b-b634-4900-94bb-d6c995387351", "name": "p1rdt7631lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "86853692-b205-4618-a7a5-8176c8cb9876"}}}}, {"uuid": "eb7a2999-86c8-4f6f-a010-1615b513d664", "name": "", "x": 38.561466725079015, "y": -122.50935425276774, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ba6ebe7f-b6b9-4f89-8bbf-7bffd63e10ef", "name": "p1rlv16268", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eb7a2999-86c8-4f6f-a010-1615b513d664"}}}}, {"uuid": "3398e448-e018-40e6-a50b-4504d0b77a7b", "name": "", "x": 38.637592171075106, "y": -122.45349611008078, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bfa76dc8-4007-4e52-9692-2eec7cb574e0", "name": "p1rdt7699lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3398e448-e018-40e6-a50b-4504d0b77a7b"}}}}, {"uuid": "dcb8b703-4cb4-4039-9993-9d9b04402c41", "name": "", "x": 38.63759072492407, "y": -122.45258089846875, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f58421d6-268b-417f-a579-c9c51d010697", "name": "p1rlv16416", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dcb8b703-4cb4-4039-9993-9d9b04402c41"}}}}, {"uuid": "1e841da1-29f5-41d4-8ba5-c88ecf63ee18", "name": "", "x": 38.63777525230912, "y": -122.45349869276687, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e60bfe9e-d2fa-4576-87f3-0a866b88d07d", "name": "p1rdm16862", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1e841da1-29f5-41d4-8ba5-c88ecf63ee18"}}}}, {"uuid": "37827724-bd74-4a74-8d3f-92058b8bebf4", "name": "", "x": 38.63771801473168, "y": -122.45282121950886, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9d908890-4fe4-4349-92de-464c4165b185", "name": "p1rlv16395", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "37827724-bd74-4a74-8d3f-92058b8bebf4"}}}}, {"uuid": "8e7d6de1-f6ed-4806-9ef0-24d1d6dbbf11", "name": "", "x": 38.636816322579385, "y": -122.45331816430568, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0cc95d09-c799-488e-81e8-50326a7da1ea", "name": "p1rdt7701lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8e7d6de1-f6ed-4806-9ef0-24d1d6dbbf11"}}}}, {"uuid": "db27e2bb-978f-4758-9ed3-644b0176ec4d", "name": "", "x": 38.63714867725408, "y": -122.45248085191842, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "323373a9-8e7d-4fb4-8970-dcc0e6d26c98", "name": "p1rlv16397", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "db27e2bb-978f-4758-9ed3-644b0176ec4d"}}}}, {"uuid": "5762879f-fed8-408b-b69c-2693dac42fd6", "name": "", "x": 38.634315239366806, "y": -122.45108169056164, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8ef392d6-b408-4a7f-8a67-9fe43e1df582", "name": "p1rdt7704lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5762879f-fed8-408b-b69c-2693dac42fd6"}}}}, {"uuid": "dbfb266a-0b63-477e-8649-ac94dbb2b196", "name": "", "x": 38.63384513963928, "y": -122.45197349911196, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "571a4c92-95b6-4bc0-a25d-0d9239a41a89", "name": "p1rlv20070", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dbfb266a-0b63-477e-8649-ac94dbb2b196"}}}}, {"uuid": "0e217484-8e6b-4d4d-af52-4413a7a594c3", "name": "", "x": 38.634430184568174, "y": -122.45121471447422, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0797f1d0-3499-4f88-a749-fc576240f791", "name": "p1rdm16872", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0e217484-8e6b-4d4d-af52-4413a7a594c3"}}}}, {"uuid": "fa4839ee-ecfc-4d14-8f46-c4b0651ff87c", "name": "", "x": 38.63430515491296, "y": -122.45145694554178, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eeb598c2-f0b9-44df-bfaa-be66e4dc3920", "name": "p1rlv16401", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa4839ee-ecfc-4d14-8f46-c4b0651ff87c"}}}}, {"uuid": "a9f961bd-cefe-4dae-ab39-0e189f5bff80", "name": "", "x": 38.63414958801971, "y": -122.4509525977873, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c5e00667-6368-49d3-a5dd-c574c79dba21", "name": "p1rdm16873", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a9f961bd-cefe-4dae-ab39-0e189f5bff80"}}}}, {"uuid": "1481206c-4e04-432b-a9f1-67ab90498892", "name": "", "x": 38.63394415582507, "y": -122.45134480308546, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d0b689f0-d4b1-4419-bff8-f72436625c60", "name": "p1rlv20068", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1481206c-4e04-432b-a9f1-67ab90498892"}}}}, {"uuid": "e97df275-6dc5-479d-a4d3-e0c412bde049", "name": "", "x": 38.633795319458095, "y": -122.45167161174345, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3f0e3c74-2d63-4612-b0e5-d986ebee0086", "name": "p1rlv20069", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e97df275-6dc5-479d-a4d3-e0c412bde049"}}}}, {"uuid": "a1266fd6-c0ee-49b8-82fc-cc6fce9a2e1b", "name": "", "x": 38.63640935476333, "y": -122.45301103214067, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "59a62487-c709-428e-9e97-c7c285a1305c", "name": "p1rdt7712lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a1266fd6-c0ee-49b8-82fc-cc6fce9a2e1b"}}}}, {"uuid": "5ad66ee7-9785-4523-a2f9-c52cd5d0b5a8", "name": "", "x": 38.636725727850084, "y": -122.45261045736181, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "99f97a6b-4e94-4a35-ad00-12e7004ab5e3", "name": "p1rlv16412", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ad66ee7-9785-4523-a2f9-c52cd5d0b5a8"}}}}, {"uuid": "3d37469f-053d-4c17-a339-a46fa2bfeb6a", "name": "", "x": 38.634298404574224, "y": -122.452544518945, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f6d10a4e-e7bc-4448-bca3-a5f2117b6198", "name": "p1rdt7718lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3d37469f-053d-4c17-a339-a46fa2bfeb6a"}}}}, {"uuid": "74a7237e-d8c7-411c-83b2-d4013f798b7a", "name": "", "x": 38.63419311757913, "y": -122.45254929248175, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f367b63c-c4cb-4810-a270-8bd0153b7b32", "name": "p1rlv16422", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "74a7237e-d8c7-411c-83b2-d4013f798b7a"}}}}, {"uuid": "4bac0a18-2477-438a-94a0-812507fc8fcd", "name": "", "x": 38.634445386111494, "y": -122.4525358843223, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c2242f1c-542f-4c1f-b3e6-19482cccde8d", "name": "p1rlv16424", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4bac0a18-2477-438a-94a0-812507fc8fcd"}}}}, {"uuid": "0a20861b-7864-4182-b71d-404098b80998", "name": "", "x": 38.65497278403905, "y": -122.46523250990784, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "96dcd934-01a0-4719-89bc-a18430edf179", "name": "p1rdt7735lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a20861b-7864-4182-b71d-404098b80998"}}}}, {"uuid": "fe1bfd41-fe22-4cbe-ab09-2fa1f2f47f5a", "name": "", "x": 38.65486042898651, "y": -122.46493056100381, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8e090544-3c8e-4716-9dae-0b311a1017ea", "name": "p1rlv16445", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fe1bfd41-fe22-4cbe-ab09-2fa1f2f47f5a"}}}}, {"uuid": "63c6b927-d3dc-4646-aec2-7061f58953c5", "name": "", "x": 38.653199252282036, "y": -122.46489297492766, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5ed564b5-8d49-4ff7-94c2-b245981472e8", "name": "p1rdt7790lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "63c6b927-d3dc-4646-aec2-7061f58953c5"}}}}, {"uuid": "98406b17-db64-435a-89ca-371b67b5b8e4", "name": "", "x": 38.65291599440307, "y": -122.46539322901351, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "53d578d8-8492-471b-8f66-233e489a3652", "name": "p1rlv16570", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "98406b17-db64-435a-89ca-371b67b5b8e4"}}}}, {"uuid": "38850062-35c5-42c4-8473-53df10d67257", "name": "", "x": 38.62241982511306, "y": -122.43971932407153, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b9dd5bb5-1410-4635-8a85-d23d7c3e55ad", "name": "p1rdt7954lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "38850062-35c5-42c4-8473-53df10d67257"}}}}, {"uuid": "40b7450c-e6b0-4a78-af62-e7c24b136327", "name": "", "x": 38.62265588015955, "y": -122.43879451092451, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7578563f-d4b3-423b-a8f5-3ee91a042d19", "name": "p1rlv16905", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "40b7450c-e6b0-4a78-af62-e7c24b136327"}}}}, {"uuid": "36950be0-4fd3-451a-9fac-8409812f4199", "name": "", "x": 38.622543574694504, "y": -122.43980628940227, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e982887d-97c6-4af5-b536-a15a372b3379", "name": "p1rdm17416", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "36950be0-4fd3-451a-9fac-8409812f4199"}}}}, {"uuid": "f39b6cba-092a-4569-9a47-5b35d3249d8e", "name": "", "x": 38.62287193593768, "y": -122.43874687668992, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4faf40b9-9ade-45b5-ade8-3f1833605cd1", "name": "p1rlv16882", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f39b6cba-092a-4569-9a47-5b35d3249d8e"}}}}, {"uuid": "967a9ca5-e96e-430d-84d9-5cdc3b729f49", "name": "", "x": 38.62281759636039, "y": -122.43998044342054, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3a96167-4b09-49c9-baf7-4fb588ecb002", "name": "p1rdt7973lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "967a9ca5-e96e-430d-84d9-5cdc3b729f49"}}}}, {"uuid": "756b813f-44fd-4a19-ba1d-6f9e311b850f", "name": "", "x": 38.623145420142684, "y": -122.43939954007212, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c2308dc3-d10b-4049-862d-caf3356fa9a7", "name": "p1rlv16912", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "756b813f-44fd-4a19-ba1d-6f9e311b850f"}}}}, {"uuid": "edeba34e-bd5b-47af-bada-d48b971f09c9", "name": "", "x": 38.62309085570953, "y": -122.43929657626467, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "11a633b0-2b09-4c66-94d4-d1c24cdd9cf5", "name": "p1rlv16988", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "edeba34e-bd5b-47af-bada-d48b971f09c9"}}}}, {"uuid": "29f78aa6-2219-41f0-b8fd-73cfb14343d6", "name": "", "x": 38.622914421161234, "y": -122.44009059423414, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "53ed549a-9c24-4bdd-9e40-aee5308d8120", "name": "p1rdm17505", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "29f78aa6-2219-41f0-b8fd-73cfb14343d6"}}}}, {"uuid": "b591bafa-ff50-4f54-a8fb-5aca6caab3c9", "name": "", "x": 38.62313800426249, "y": -122.43973273911827, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4c570ef7-c483-4c1e-b0fd-8712e8e9a7cd", "name": "p1rlv16904", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b591bafa-ff50-4f54-a8fb-5aca6caab3c9"}}}}, {"uuid": "b8e4d113-43ab-498e-ba02-2cda8df4a829", "name": "", "x": 38.618288153419634, "y": -122.43508780454101, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cb63be48-94ec-4c9f-9991-77892e14171b", "name": "p1rdt7983lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b8e4d113-43ab-498e-ba02-2cda8df4a829"}}}}, {"uuid": "786f1d10-0412-4963-9e25-0d1e156451c2", "name": "", "x": 38.6178110723834, "y": -122.43578826842699, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "07e01053-37f3-4b9f-a9f1-d51bccd29803", "name": "p1rlv16919", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "786f1d10-0412-4963-9e25-0d1e156451c2"}}}}, {"uuid": "ecbeb3c5-deaf-40f8-b0f7-c5efa49d8122", "name": "", "x": 38.617981016890134, "y": -122.43552274050253, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dfa28657-cd8e-4700-a189-83e021f77bee", "name": "p1rlv17033", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ecbeb3c5-deaf-40f8-b0f7-c5efa49d8122"}}}}, {"uuid": "9b9c7472-9dea-4ebe-8b54-92c0d3484b0a", "name": "", "x": 38.60009989462982, "y": -122.45165246954828, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "415fe6e9-953e-40f6-8ae8-43834e4e6ce4", "name": "p1rdt7986lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9b9c7472-9dea-4ebe-8b54-92c0d3484b0a"}}}}, {"uuid": "ae9eb3b3-537f-40c2-943f-3469e0711386", "name": "", "x": 38.60019584777296, "y": -122.45157886471317, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ce315d98-1556-429b-aebb-0c868892396a", "name": "p1rlv16922", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ae9eb3b3-537f-40c2-943f-3469e0711386"}}}}, {"uuid": "e1274621-2f83-4c64-9c96-f50c8d474a6c", "name": "", "x": 38.5999461596242, "y": -122.45214347781915, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7dff1455-5154-429f-a33f-044d8501281d", "name": "p1rlv16957", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e1274621-2f83-4c64-9c96-f50c8d474a6c"}}}}, {"uuid": "85b83e09-ec12-486f-ad2e-0555a1ba557f", "name": "", "x": 38.60009505177635, "y": -122.45122362894173, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "19130741-0fe1-4a12-8a55-96355609bccb", "name": "p1rlv17063", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "85b83e09-ec12-486f-ad2e-0555a1ba557f"}}}}, {"uuid": "6897a9e4-802b-4dc9-a6ca-c8eca130dd9c", "name": "", "x": 38.61708288860949, "y": -122.43744053773406, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "94f12107-697c-4278-95e0-32b6eb49fdb3", "name": "p1rdt7988lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6897a9e4-802b-4dc9-a6ca-c8eca130dd9c"}}}}, {"uuid": "999335b2-ae36-40cb-9fd3-b2738191bb3d", "name": "", "x": 38.61700772395571, "y": -122.43739120644287, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ba1d053-4462-4eb4-aca6-5ede38aa283c", "name": "p1rlv16926", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "999335b2-ae36-40cb-9fd3-b2738191bb3d"}}}}, {"uuid": "52cf2f27-de63-46c8-92e2-0e220ca503d5", "name": "", "x": 38.6171461348718, "y": -122.43747450374505, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5439f343-8176-4d92-99d4-bb9209817f6b", "name": "p1rlv17106", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "52cf2f27-de63-46c8-92e2-0e220ca503d5"}}}}, {"uuid": "f1373852-4d12-4fab-86ca-a37b50a04f22", "name": "", "x": 38.62030446603571, "y": -122.4376486590166, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f5b22c57-7912-4e9f-9b06-6a8ff706a58d", "name": "p1rdt8012lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f1373852-4d12-4fab-86ca-a37b50a04f22"}}}}, {"uuid": "0a779003-8296-47e1-b30a-ece8f8025987", "name": "", "x": 38.619635701851216, "y": -122.43854235774572, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "57e8aa34-3967-4f22-a978-cb513c49c153", "name": "p1rlv16992", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a779003-8296-47e1-b30a-ece8f8025987"}}}}, {"uuid": "3b30dab7-8ea2-4d20-afae-2bb1a6efded1", "name": "", "x": 38.61994945069005, "y": -122.43819529796752, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bd48a076-5f8f-426a-b294-183700d1a123", "name": "p1rlv17069", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3b30dab7-8ea2-4d20-afae-2bb1a6efded1"}}}}, {"uuid": "a2a5e5d8-edf7-451c-b710-08f3ebe5620f", "name": "", "x": 38.60637102325893, "y": -122.45140950104778, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a6c5d7ff-cfcd-4b30-98db-eb44a95d6841", "name": "p1rdt8015lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a2a5e5d8-edf7-451c-b710-08f3ebe5620f"}}}}, {"uuid": "6a96ff2a-cd9b-4d06-8c13-ef04fa2bd59d", "name": "", "x": 38.60632273742159, "y": -122.45132550281518, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f23214ee-3032-4403-9084-8117e89cb1cf", "name": "p1rlv17001", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a96ff2a-cd9b-4d06-8c13-ef04fa2bd59d"}}}}, {"uuid": "d18a87e9-8f1c-4a7a-bf3f-195c6b8f25a2", "name": "", "x": 38.60636860276844, "y": -122.45149742797311, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "213e6d98-ad57-4034-b2d0-4b096554cac2", "name": "p1rlv17028", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d18a87e9-8f1c-4a7a-bf3f-195c6b8f25a2"}}}}, {"uuid": "74928a51-a3eb-4475-a089-b643f8e3cddd", "name": "", "x": 38.620582059906845, "y": -122.43797607749299, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "972fe574-f88e-4a8d-8845-d5baa2f378a7", "name": "p1rdt8034lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "74928a51-a3eb-4475-a089-b643f8e3cddd"}}}}, {"uuid": "57807a14-3fcd-490d-a976-2296f5ca4a86", "name": "", "x": 38.620214408134636, "y": -122.43835802321873, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "92aff718-b70f-4ea4-b38b-fae69a470c58", "name": "p1rlv17059", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "57807a14-3fcd-490d-a976-2296f5ca4a86"}}}}, {"uuid": "652294b0-563d-4bfd-b434-dcdbf4f1f2c8", "name": "", "x": 38.59894295708058, "y": -122.46830816449578, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9951633b-4311-4ca2-9316-3801be13fe97", "name": "p1rdt8149lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "652294b0-563d-4bfd-b434-dcdbf4f1f2c8"}}}}, {"uuid": "24cd4106-fd1e-4e94-a044-53af52c6d2ca", "name": "", "x": 38.598821308346544, "y": -122.46812594296912, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d9778ed5-f0c0-44de-b0d4-60659a54fa3b", "name": "p1rlv17319", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "24cd4106-fd1e-4e94-a044-53af52c6d2ca"}}}}, {"uuid": "f10ee951-5720-4c53-bd7f-7ff21679759b", "name": "", "x": 38.598867566369016, "y": -122.46838972837861, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4970bc03-bc57-4a42-b0cb-66002af1709e", "name": "p1rlv17334", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f10ee951-5720-4c53-bd7f-7ff21679759b"}}}}, {"uuid": "be323039-e11a-4d50-ae15-10c1ce1c9187", "name": "", "x": 38.59870152218132, "y": -122.4669250043453, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6cd1ae47-6aaa-4b57-ba44-1e74f6ea54b7", "name": "p1rdt8150lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be323039-e11a-4d50-ae15-10c1ce1c9187"}}}}, {"uuid": "2876bba6-9299-413f-b90c-6f858847f3c5", "name": "", "x": 38.59827116190417, "y": -122.46741050201447, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "79991b02-c0f1-4b9b-a55e-e9b4ff7c17d9", "name": "p1rlv17320", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2876bba6-9299-413f-b90c-6f858847f3c5"}}}}, {"uuid": "7dbc0a5b-096f-467d-8654-2443b4048e03", "name": "", "x": 38.599111058885946, "y": -122.46644716803104, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6ceb2d77-2da7-44df-9f28-69ed35835775", "name": "p1rlv17326", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7dbc0a5b-096f-467d-8654-2443b4048e03"}}}}, {"uuid": "7e3afdac-e798-4f5f-a6bf-8b16a3ecc303", "name": "", "x": 38.599727655355764, "y": -122.4681198081272, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75a8deb5-b46b-4d4c-876c-b44b2258a6fa", "name": "p1rdt8151lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7e3afdac-e798-4f5f-a6bf-8b16a3ecc303"}}}}, {"uuid": "65e01278-ee98-422b-a1ee-5e7071567570", "name": "", "x": 38.599692587118206, "y": -122.46815246602429, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "00ed745d-78ae-47f6-b6ef-4edf8794ca6a", "name": "p1rdt8151lv-p1rlv17321x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65e01278-ee98-422b-a1ee-5e7071567570"}}}}, {"uuid": "e413bf90-133e-4824-8fae-b54739e28318", "name": "", "x": 38.599654808831716, "y": -122.46817784954497, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "94ce8ee2-6f57-407a-93e9-c06f79d66262", "name": "p1rdt8151lv-p1rlv17321xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e413bf90-133e-4824-8fae-b54739e28318"}}}}, {"uuid": "b16cfa2e-327a-4cd1-af35-0b3f8d8e6192", "name": "", "x": 38.59971750379885, "y": -122.46702835755418, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ce41ac7c-06c5-435a-957d-c9dda83c1893", "name": "p1rlv17321", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b16cfa2e-327a-4cd1-af35-0b3f8d8e6192"}}}}, {"uuid": "51b25475-572c-43ef-b08b-4bc4bc2e516d", "name": "", "x": 38.599821698957996, "y": -122.46814152774704, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "abb24254-be79-45d4-8d9b-246b3e89c00f", "name": "p1rlv20188", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "51b25475-572c-43ef-b08b-4bc4bc2e516d"}}}}, {"uuid": "73645010-aad0-4777-9ab9-4d588ae8adc5", "name": "", "x": 38.59932106464093, "y": -122.4698880830305, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7a542ca5-b24e-44dc-8b68-c00aa024afad", "name": "p1rdt8153lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "73645010-aad0-4777-9ab9-4d588ae8adc5"}}}}, {"uuid": "bcc547e6-c25f-4156-a23e-52ef6e3c66a3", "name": "", "x": 38.59930726241313, "y": -122.4699390974389, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9b96606c-9336-4299-be8d-295c84943a9d", "name": "p1rlv17325", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bcc547e6-c25f-4156-a23e-52ef6e3c66a3"}}}}, {"uuid": "12a4a536-86b1-4eea-a894-3802183a70e7", "name": "", "x": 38.5995160751222, "y": -122.47116135904078, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32fefbef-e10b-4758-8c2e-ccafad49aa5d", "name": "p1rdt8154lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "12a4a536-86b1-4eea-a894-3802183a70e7"}}}}, {"uuid": "bc792def-db51-4a96-a8b0-19f05e3269c4", "name": "", "x": 38.59950227233904, "y": -122.4712123733502, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a43eb022-d5e0-47c8-aa36-6ca0d212ab07", "name": "p1rlv17328", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bc792def-db51-4a96-a8b0-19f05e3269c4"}}}}, {"uuid": "c3d91646-a40b-40ca-80bb-61f7e6f26a01", "name": "", "x": 38.598945724578684, "y": -122.46814818814434, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "51812cd8-eec8-4862-8413-d25a7e9862dc", "name": "p1rdt8155lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c3d91646-a40b-40ca-80bb-61f7e6f26a01"}}}}, {"uuid": "fc85bc7f-eb62-491d-a8dd-e16c26eaa370", "name": "", "x": 38.59855694337255, "y": -122.46746183798086, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "61ef37c1-f14f-4b79-a428-d51a6f0d076a", "name": "p1rlv17329", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fc85bc7f-eb62-491d-a8dd-e16c26eaa370"}}}}, {"uuid": "85a37c02-3c14-40bb-9d81-588a0997012f", "name": "", "x": 38.59929944436906, "y": -122.4682372527046, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cb2a5041-28a1-4fda-905b-caf53ebbefe3", "name": "p1rdm17903", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "85a37c02-3c14-40bb-9d81-588a0997012f"}}}}, {"uuid": "600dd5af-b1ef-4e7d-9206-2af3992c0b0d", "name": "", "x": 38.599299287824266, "y": -122.46820280233233, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48ad7bb0-8dd7-457a-b77d-6db2071c2fe7", "name": "p1rlv17330", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "600dd5af-b1ef-4e7d-9206-2af3992c0b0d"}}}}, {"uuid": "c6354fad-0bf0-4b9f-8e5b-9393b20d716a", "name": "", "x": 38.59897593725153, "y": -122.46956906444683, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fa6d4429-8a95-4ebd-9e3a-9867734245bd", "name": "p1rdt8157lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c6354fad-0bf0-4b9f-8e5b-9393b20d716a"}}}}, {"uuid": "bafc48cf-5d8c-4306-98a9-d215091f7b50", "name": "", "x": 38.598949958035, "y": -122.46952646674691, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33b66eb9-3b21-4f92-b19b-6a0eef4134d8", "name": "p1rlv17333", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bafc48cf-5d8c-4306-98a9-d215091f7b50"}}}}, {"uuid": "90af01ca-1950-494d-b325-b227d69c91bf", "name": "", "x": 38.64315249575866, "y": -122.47114976892446, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e1dd4660-3cd0-4709-b1ef-1c598e5e39fb", "name": "p1rdt8159lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "90af01ca-1950-494d-b325-b227d69c91bf"}}}}, {"uuid": "fb4f265f-b768-470b-b88f-c854b51fcff9", "name": "", "x": 38.64322634740489, "y": -122.47091189149079, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a5d0a174-d49d-4c7e-a669-092f6408edf4", "name": "p1rlv20480", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fb4f265f-b768-470b-b88f-c854b51fcff9"}}}}, {"uuid": "e08079d3-edd1-4bc8-b081-44dd5362f947", "name": "", "x": 38.64301980977188, "y": -122.47107428162515, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3484e698-3a4e-4a88-aaa3-1dc88cd9ac89", "name": "p1rdm17907", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e08079d3-edd1-4bc8-b081-44dd5362f947"}}}}, {"uuid": "bda4f4c6-ba52-422b-bb2d-4154135e8feb", "name": "", "x": 38.64306413997204, "y": -122.47091308420728, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0b645969-9136-42a9-b5ac-7d2f1ff71959", "name": "p1rlv17336", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bda4f4c6-ba52-422b-bb2d-4154135e8feb"}}}}, {"uuid": "cea73a9b-9f97-4242-820d-0a18752b434b", "name": "", "x": 38.643206712841376, "y": -122.47055581957126, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7af262b7-285c-4d06-b7ff-2f2a1971055a", "name": "p1rlv20492", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cea73a9b-9f97-4242-820d-0a18752b434b"}}}}, {"uuid": "dcb6e9c3-b78b-427f-835d-56f4c83eb710", "name": "", "x": 38.64331796921429, "y": -122.47124445290501, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6112cc26-bc37-4c72-8ef6-cd88f1296693", "name": "p1rdm17908", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dcb6e9c3-b78b-427f-835d-56f4c83eb710"}}}}, {"uuid": "0b5adf50-29df-4ada-9ca9-a7c149090ecb", "name": "", "x": 38.64340709749659, "y": -122.47102547122093, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8934db59-0c39-4838-9f8c-59a563cd9d54", "name": "p1rlv20455", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0b5adf50-29df-4ada-9ca9-a7c149090ecb"}}}}, {"uuid": "4410ab61-f4d7-4686-b7a5-9283f71a955f", "name": "", "x": 38.647797936596966, "y": -122.46665816549304, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "232fed6b-fe0f-4a44-93e9-e6675b50c39c", "name": "p1rdt8160lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4410ab61-f4d7-4686-b7a5-9283f71a955f"}}}}, {"uuid": "6ba1a4ef-2877-4400-a039-d27b9912e1d2", "name": "", "x": 38.64781228772558, "y": -122.4667089672996, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d5d7049e-9d30-474c-9033-3ad9b4487f7a", "name": "p1rlv17337", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6ba1a4ef-2877-4400-a039-d27b9912e1d2"}}}}, {"uuid": "a8334a25-2ec8-45e1-90a0-56ac56a0edc3", "name": "", "x": 38.644602062665655, "y": -122.47222549352858, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ac7e489e-7249-4702-9ed6-131cad34500f", "name": "p1rdt8161lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8334a25-2ec8-45e1-90a0-56ac56a0edc3"}}}}, {"uuid": "14ba7656-3e7a-48eb-84c9-cff77db459fd", "name": "", "x": 38.644748791082094, "y": -122.47278523601162, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "331389ab-5d04-4648-83b4-3043198c774f", "name": "p1rlv17338", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "14ba7656-3e7a-48eb-84c9-cff77db459fd"}}}}, {"uuid": "0680cc6e-da56-4ac2-b868-8618f91b4a6a", "name": "", "x": 38.617206962751396, "y": -122.42934627658663, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9560197a-21d1-4601-8bcb-213df4844f4a", "name": "p1rdt8346lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0680cc6e-da56-4ac2-b868-8618f91b4a6a"}}}}, {"uuid": "87600d73-a33f-43c6-92ff-0cbccc7eef41", "name": "", "x": 38.61718096900156, "y": -122.4293036828715, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7acb4e7d-cb06-4848-952d-7c68bb34b6db", "name": "p1rlv17702", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "87600d73-a33f-43c6-92ff-0cbccc7eef41"}}}}, {"uuid": "d12a0724-e31b-404e-8bac-0c3f130fa7e6", "name": "", "x": 38.61731941811156, "y": -122.46431093057339, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "408d5d7b-fc71-46bb-8de0-2d4e628c29b6", "name": "p1rdt8405lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d12a0724-e31b-404e-8bac-0c3f130fa7e6"}}}}, {"uuid": "59b1e009-bbd6-4229-8a8f-0ffc8ba2fd39", "name": "", "x": 38.61734493344011, "y": -122.46426786943886, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a52db2ff-b782-40c1-828a-c65f6929b2fc", "name": "p1rlv17781", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59b1e009-bbd6-4229-8a8f-0ffc8ba2fd39"}}}}, {"uuid": "4baa2cfd-b95d-4843-9f15-6446ca83fe8b", "name": "", "x": 38.62043416913732, "y": -122.45626485935486, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3fe0f77-a7c1-48e3-94aa-30b69f20ca65", "name": "p1rdt8408lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4baa2cfd-b95d-4843-9f15-6446ca83fe8b"}}}}, {"uuid": "1eae8901-0307-473a-a766-33150cf5b60b", "name": "", "x": 38.62067425594847, "y": -122.4561786638706, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9c9c1d9f-eeff-454f-b3d0-7e7de837694c", "name": "p1rlv17787", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1eae8901-0307-473a-a766-33150cf5b60b"}}}}, {"uuid": "bab9d82d-9b34-48ac-b25c-565c4824842b", "name": "", "x": 38.62014326917501, "y": -122.45633200676872, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b40fac8c-a99b-4baa-940a-26565ba7d62b", "name": "p1rlv18044", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bab9d82d-9b34-48ac-b25c-565c4824842b"}}}}, {"uuid": "c80213c4-13ed-4f25-a3db-f0e44ee86016", "name": "", "x": 38.62377947083559, "y": -122.45617863919693, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fca92353-c013-4c41-8507-ec8704410834", "name": "p1rdt8414lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c80213c4-13ed-4f25-a3db-f0e44ee86016"}}}}, {"uuid": "3bbdb11f-382f-4722-98b6-18945dc957b4", "name": "", "x": 38.623816236226766, "y": -122.4555001331194, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d9dba02d-086c-4906-9c6f-86532e3384c0", "name": "p1rlv17798", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3bbdb11f-382f-4722-98b6-18945dc957b4"}}}}, {"uuid": "f094ddcf-5d31-4a5f-853f-8314aa17aa7b", "name": "", "x": 38.59895000377746, "y": -122.46337821887984, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cfe35c35-8164-4825-81e3-10a2ece2cb27", "name": "p1rdt8422lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f094ddcf-5d31-4a5f-853f-8314aa17aa7b"}}}}, {"uuid": "0036a891-6aaf-4b34-8cf0-810e4e8d6bf0", "name": "", "x": 38.59842227673629, "y": -122.46362727672292, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3887a879-0783-4703-8a24-32b7e3b4f39d", "name": "p1rlv17810", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0036a891-6aaf-4b34-8cf0-810e4e8d6bf0"}}}}, {"uuid": "b81a4b3e-aeac-4baf-bc74-00bc42937f30", "name": "", "x": 38.59798139328054, "y": -122.46377984508203, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6f7776e4-a81f-48d2-b3c0-d70bfa48164e", "name": "p1rlv17847", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b81a4b3e-aeac-4baf-bc74-00bc42937f30"}}}}, {"uuid": "6e44a3e6-b8a2-4262-8184-2c558056127d", "name": "", "x": 38.598224600790864, "y": -122.46375506824658, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75e55237-b847-4fb7-a141-a0771bd868c6", "name": "p1rlv17876", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6e44a3e6-b8a2-4262-8184-2c558056127d"}}}}, {"uuid": "3e55eaf4-6618-482f-b4e3-c232453615b3", "name": "", "x": 38.59902589482566, "y": -122.46358833294255, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a7421f5c-bf5c-4d01-aa14-ba657f242080", "name": "p1rdm18545", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e55eaf4-6618-482f-b4e3-c232453615b3"}}}}, {"uuid": "e8a52517-868f-4231-8bad-cc741df29cce", "name": "", "x": 38.598360195447086, "y": -122.46384592887894, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2716887e-1701-4a78-805b-96da0781c7f8", "name": "p1rlv17961", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e8a52517-868f-4231-8bad-cc741df29cce"}}}}, {"uuid": "0ddbc6a9-40f9-4e00-a77f-e50a854446b3", "name": "", "x": 38.597552657762314, "y": -122.45740568785139, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cdc5ef2a-c0d0-4702-b6c6-df08af1e8746", "name": "p1rdt8434lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0ddbc6a9-40f9-4e00-a77f-e50a854446b3"}}}}, {"uuid": "c280eb31-f020-492f-8511-02bbf631c40b", "name": "", "x": 38.59741052481255, "y": -122.45723847553955, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0827675c-2467-403d-822e-5f74cd6296c5", "name": "p1rlv17857", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c280eb31-f020-492f-8511-02bbf631c40b"}}}}, {"uuid": "e0797818-9133-4fd4-93f8-5ecdb12592b1", "name": "", "x": 38.59577787216432, "y": -122.45996961185554, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b24c9345-625f-499d-96cf-30b2de5839b6", "name": "p1rdt8436lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e0797818-9133-4fd4-93f8-5ecdb12592b1"}}}}, {"uuid": "6b2266b6-8a5f-4e6d-8b4b-b4d91bf314c5", "name": "", "x": 38.59575188947818, "y": -122.45992701953358, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f44b0293-61e5-4054-b2d7-4a113df92b3c", "name": "p1rlv17877", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6b2266b6-8a5f-4e6d-8b4b-b4d91bf314c5"}}}}, {"uuid": "235a5cab-5833-447d-938d-8458cbfe5858", "name": "", "x": 38.61790022449083, "y": -122.4571375571412, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a38f544-e250-4fc9-942c-946c5cde0a33", "name": "p1rdt8439lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "235a5cab-5833-447d-938d-8458cbfe5858"}}}}, {"uuid": "ae72de9d-225e-480d-9e53-9d298035cd06", "name": "", "x": 38.61807504073576, "y": -122.45730102691826, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3f74f217-4765-406d-9646-d8f46377ef0a", "name": "p1rlv17897", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ae72de9d-225e-480d-9e53-9d298035cd06"}}}}, {"uuid": "d1f565f4-1b19-4624-acab-6843789b0f04", "name": "", "x": 38.597579593964674, "y": -122.45871858209406, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c6460e5c-839d-4f9e-b9d6-b187fddb9ab6", "name": "p1rdm18631", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1f565f4-1b19-4624-acab-6843789b0f04"}}}}, {"uuid": "e30f89b8-4654-434d-a298-685c0c334130", "name": "", "x": 38.59739305808095, "y": -122.45930564328731, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ab733d49-bb36-4631-8824-1967f98f758a", "name": "p1rlv17909", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e30f89b8-4654-434d-a298-685c0c334130"}}}}, {"uuid": "b0e348c6-668d-45f5-89d6-80130a49de58", "name": "", "x": 38.59774507812581, "y": -122.45881317872153, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "049362b4-49de-4e80-921e-ff763aaab2d1", "name": "p1rdt8440lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b0e348c6-668d-45f5-89d6-80130a49de58"}}}}, {"uuid": "6eb673d0-753b-41b4-9d72-6e3b93827970", "name": "", "x": 38.59785985557703, "y": -122.45891169861048, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7633fe6b-a48b-4e7d-90e6-a38b8a861936", "name": "p1rdm18632", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6eb673d0-753b-41b4-9d72-6e3b93827970"}}}}, {"uuid": "7b013b37-85eb-43c0-8866-e81aa9d95460", "name": "", "x": 38.59783092542888, "y": -122.45911464995726, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1ccaf70a-35d8-4f16-b632-e282fe30b5ca", "name": "p1rlv17969", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7b013b37-85eb-43c0-8866-e81aa9d95460"}}}}, {"uuid": "50b1484b-4818-4428-9e9a-3bde30411fd7", "name": "", "x": 38.592426036395636, "y": -122.46351864990689, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "72c8f08a-0ba5-413e-a805-f9436b41ff29", "name": "p1rdt8441lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "50b1484b-4818-4428-9e9a-3bde30411fd7"}}}}, {"uuid": "a04c8189-e692-459c-a5f1-48dde6ab4744", "name": "", "x": 38.59244738401374, "y": -122.46362580620794, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3eb66d3-0271-4842-8893-9a58f64e0279", "name": "p1rlv17912", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a04c8189-e692-459c-a5f1-48dde6ab4744"}}}}, {"uuid": "8a776ad0-780d-4247-ade1-f5cf9ea31a4b", "name": "", "x": 38.597607065823205, "y": -122.46357324186411, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6b5ae28a-95f8-4023-aa23-36809fe96b10", "name": "p1rdt8442lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8a776ad0-780d-4247-ade1-f5cf9ea31a4b"}}}}, {"uuid": "b197b384-d376-4d94-876a-0a809b11da97", "name": "", "x": 38.597593266344134, "y": -122.46362425623258, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2812bbb1-0bb0-499f-a394-0995784bb7bc", "name": "p1rlv17926", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b197b384-d376-4d94-876a-0a809b11da97"}}}}, {"uuid": "867451dd-75d8-47b5-bd21-ccfa0b329ea5", "name": "", "x": 38.59572176348798, "y": -122.45708645620138, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "978920e8-edf9-4bee-85f9-45f4081ed0ca", "name": "p1rdt8444lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "867451dd-75d8-47b5-bd21-ccfa0b329ea5"}}}}, {"uuid": "105845cf-c40d-4173-81fd-b74861397ce6", "name": "", "x": 38.59568814197167, "y": -122.45699881396531, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "215a5974-e23b-46f0-bde9-f5ad16fdfaf8", "name": "p1rlv17960", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "105845cf-c40d-4173-81fd-b74861397ce6"}}}}, {"uuid": "10f191de-e023-4808-85f5-012176f1336e", "name": "", "x": 38.595797079946, "y": -122.45717024246757, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "86917829-123c-4fda-9809-dc61430a9fef", "name": "p1rlv18071", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10f191de-e023-4808-85f5-012176f1336e"}}}}, {"uuid": "e52bb183-08e0-4285-8429-5d7606c19fe0", "name": "", "x": 38.61751627823996, "y": -122.46078567224485, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7e0923da-550b-479f-b3d8-3e0320db6701", "name": "p1rdt8445lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e52bb183-08e0-4285-8429-5d7606c19fe0"}}}}, {"uuid": "a8649d36-5197-4a25-b6b5-550f77429a73", "name": "", "x": 38.61713929235215, "y": -122.46152369067127, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ec99daac-e0be-4ea1-ba4f-185d4943396d", "name": "p1rlv17962", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8649d36-5197-4a25-b6b5-550f77429a73"}}}}, {"uuid": "664da3a5-5133-402f-8d86-f3c67ca71d77", "name": "", "x": 38.62155491914008, "y": -122.45674368662482, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5dbc3459-6a17-4075-899a-6aab16fb3ab7", "name": "p1rdt8447lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "664da3a5-5133-402f-8d86-f3c67ca71d77"}}}}, {"uuid": "98a16178-ae9b-49b9-9dba-5f7325d4f142", "name": "", "x": 38.6215289352912, "y": -122.45670108034808, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0771ebfa-5eaf-4ae8-94f1-86de7a656f58", "name": "p1rlv17987", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "98a16178-ae9b-49b9-9dba-5f7325d4f142"}}}}, {"uuid": "605fd3a1-c920-45b2-ad64-ca60322bc1c0", "name": "", "x": 38.59745455680166, "y": -122.45591485249561, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8b4216c8-9e99-446c-ad09-5a09f046dd59", "name": "p1rdt8450lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "605fd3a1-c920-45b2-ad64-ca60322bc1c0"}}}}, {"uuid": "f8e8c7c1-26b6-495f-9e34-86907f86c0ad", "name": "", "x": 38.597480069191974, "y": -122.45587180037909, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4aeda1c7-41be-43c8-82e5-d7a347db86a8", "name": "p1rlv18053", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f8e8c7c1-26b6-495f-9e34-86907f86c0ad"}}}}, {"uuid": "ac621d29-9618-4700-9b16-28e6618b6676", "name": "", "x": 38.623331409033426, "y": -122.45649925442898, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d094b779-ebcc-4837-9ccb-31808e2a544b", "name": "p1rdt8456lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ac621d29-9618-4700-9b16-28e6618b6676"}}}}, {"uuid": "722dda28-849d-4e17-a584-550e06ef2a68", "name": "", "x": 38.62321497484187, "y": -122.45604459936547, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c4863d28-4ee2-479d-accb-60b54f472fe7", "name": "p1rlv18100", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "722dda28-849d-4e17-a584-550e06ef2a68"}}}}, {"uuid": "dc23a352-01e5-4e67-9210-bb6fbafba6c4", "name": "", "x": 38.62104504107823, "y": -122.4556217772947, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e597d8da-e876-44a5-a109-1ce84527c557", "name": "p1rdt8458lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dc23a352-01e5-4e67-9210-bb6fbafba6c4"}}}}, {"uuid": "f36410e9-465d-44f3-8ab5-6e0fd2624084", "name": "", "x": 38.62101905682373, "y": -122.45557917172717, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "115a848f-f6f3-48f0-9f33-5a9103f1a892", "name": "p1rlv18129", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f36410e9-465d-44f3-8ab5-6e0fd2624084"}}}}, {"uuid": "804f0048-b140-4280-ba5b-87306c6feacc", "name": "", "x": 38.6478890270985, "y": -122.44178196559784, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "edb15d92-f98a-4fa2-8129-ad8a39e0dc0c", "name": "p1rdt8470lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "804f0048-b140-4280-ba5b-87306c6feacc"}}}}, {"uuid": "4ba6adc1-6162-4155-a2bd-22b86bf1188e", "name": "", "x": 38.6478781196749, "y": -122.4418348710007, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "431692e5-2917-41ea-aafc-96be180b7e27", "name": "p1rlv18166", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ba6adc1-6162-4155-a2bd-22b86bf1188e"}}}}, {"uuid": "b73e98fa-cf90-4060-8e49-9e9faf47c7fb", "name": "", "x": 38.59296538348102, "y": -122.52138816471086, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a84e1424-7faf-4077-9461-b39460f10ef0", "name": "p1rdt8490lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b73e98fa-cf90-4060-8e49-9e9faf47c7fb"}}}}, {"uuid": "ed117aae-82ac-4c66-942a-b71b10ab7463", "name": "", "x": 38.59301371324328, "y": -122.5214951600568, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1c3e08a8-ea88-423d-b361-69509f7ab8fa", "name": "p1rlv18192", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ed117aae-82ac-4c66-942a-b71b10ab7463"}}}}, {"uuid": "5ebb3cfc-a5b0-49a9-a24f-877580473c4b", "name": "", "x": 38.59294983327106, "y": -122.521300375614, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5a7cb078-af6c-4cd5-9aca-48f515f6e711", "name": "p1rlv18198", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ebb3cfc-a5b0-49a9-a24f-877580473c4b"}}}}, {"uuid": "de057e16-abb7-41f6-af51-aebbadc2b25b", "name": "", "x": 38.59325808671421, "y": -122.5203178073169, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "127e4cc7-6413-4482-9ec3-40f8bde02d0c", "name": "p1rdt8492lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "de057e16-abb7-41f6-af51-aebbadc2b25b"}}}}, {"uuid": "ef8d5eb6-940c-46a1-831a-9669016160a2", "name": "", "x": 38.59327241449537, "y": -122.5203685817209, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c5e240e8-b27d-4181-a7ee-a004d3f5c58a", "name": "p1rlv18197", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef8d5eb6-940c-46a1-831a-9669016160a2"}}}}, {"uuid": "a61ec7ca-3ace-4736-9144-904c04e0c148", "name": "", "x": 38.60984174522787, "y": -122.47657385883775, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "95a1a7c7-6055-47c9-a742-c1b81f6c7478", "name": "p1rdt8802lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a61ec7ca-3ace-4736-9144-904c04e0c148"}}}}, {"uuid": "a6e85fe6-c716-4a0f-a8c2-0f24fd3a2386", "name": "", "x": 38.609856091968865, "y": -122.47662463597939, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9178fdee-311f-40f5-bdd6-9b474a05247e", "name": "p1rlv18960", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a6e85fe6-c716-4a0f-a8c2-0f24fd3a2386"}}}}, {"uuid": "2f141231-7a01-4055-8435-d27aaab6e5a0", "name": "", "x": 38.60811019336638, "y": -122.4764535430088, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "715c92fa-2470-4869-8d5f-0b4f3f8360d4", "name": "p1rdt8805lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2f141231-7a01-4055-8435-d27aaab6e5a0"}}}}, {"uuid": "8dee19e0-8f93-421c-89dc-21a73c4b7405", "name": "", "x": 38.60841504125986, "y": -122.4772548473748, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eef4f0cf-6e51-45e1-8b6e-84171f7cbef6", "name": "p1rlv18967", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8dee19e0-8f93-421c-89dc-21a73c4b7405"}}}}, {"uuid": "44c9f757-2bb1-4fa1-b546-bd34b4b7f2f9", "name": "", "x": 38.581410942364535, "y": -122.50908841868979, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f6ff626c-d2fc-4b97-9013-4fd544d946a2", "name": "p1rdt8898lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "44c9f757-2bb1-4fa1-b546-bd34b4b7f2f9"}}}}, {"uuid": "57fd1592-5243-4363-8282-086d2487b045", "name": "", "x": 38.58102797028686, "y": -122.50847493360112, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2cf28b5d-d8d4-4883-a396-2d1ad9b70564", "name": "p1rlv19157", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "57fd1592-5243-4363-8282-086d2487b045"}}}}, {"uuid": "f3f75cf1-080c-47d4-977e-453e2b885282", "name": "", "x": 38.58165154784808, "y": -122.50878549370569, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "09d59048-6e1b-4f7f-b161-81163809eb25", "name": "p1rdm19752", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f3f75cf1-080c-47d4-977e-453e2b885282"}}}}, {"uuid": "e8ccc470-71ba-4c98-aee7-701cc49838f9", "name": "", "x": 38.581235479806075, "y": -122.50853092416536, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "67a4600d-65c3-40d7-ad28-e8e37ff77dcb", "name": "p1rlv19149", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e8ccc470-71ba-4c98-aee7-701cc49838f9"}}}}, {"uuid": "b56887ea-0407-49d2-a1d7-9cbc77058ca0", "name": "", "x": 38.581243768243056, "y": -122.5083586529402, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c7c1d210-ee87-46c5-b408-ad221cbeed04", "name": "p1rlv19160", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b56887ea-0407-49d2-a1d7-9cbc77058ca0"}}}}, {"uuid": "240e4997-1186-4c77-b45b-065a2ebd972c", "name": "", "x": 38.58115574730252, "y": -122.50928817819602, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a7664d29-bbc0-4465-a00a-82af048b86e5", "name": "p1rdm19755", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "240e4997-1186-4c77-b45b-065a2ebd972c"}}}}, {"uuid": "2d04d1e5-eafb-4f34-b561-44619bce9aa4", "name": "", "x": 38.58064928716368, "y": -122.50843159103809, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "994f6392-f4e5-4ff8-9eeb-5849cd035912", "name": "p1rlv19166", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2d04d1e5-eafb-4f34-b561-44619bce9aa4"}}}}, {"uuid": "e8c464bc-8647-472f-ae74-067475e1724b", "name": "", "x": 38.58121826088946, "y": -122.50725268309377, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d53c0a2-78cc-4988-85a4-884ef039f5fa", "name": "p1rdt8901lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e8c464bc-8647-472f-ae74-067475e1724b"}}}}, {"uuid": "11091ed9-9278-418b-a4b8-3759b0797ce7", "name": "", "x": 38.58123620687723, "y": -122.50802972585609, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16df6b90-d049-4160-b148-b888e03acb82", "name": "p1rlv19161", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "11091ed9-9278-418b-a4b8-3759b0797ce7"}}}}, {"uuid": "064e0b49-6ead-4a53-af44-38565a7e6781", "name": "", "x": 38.65991234943945, "y": -122.43854233081237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e111e213-bcbe-42c4-b6ab-2c734ff5341c", "name": "p1rdt8904lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "064e0b49-6ead-4a53-af44-38565a7e6781"}}}}, {"uuid": "40047848-7a14-4001-aecf-88ae0011c629", "name": "", "x": 38.660223463841156, "y": -122.43823709517063, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1f8c76ca-40ea-4f7d-8042-66edd484f065", "name": "p1rlv19168", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "40047848-7a14-4001-aecf-88ae0011c629"}}}}, {"uuid": "f8047d0f-fd7f-4cd1-a199-62ef50463692", "name": "", "x": 38.659990269866015, "y": -122.43846878718209, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e0fc7d43-4f82-4100-99bf-6e30e03e95ce", "name": "p1rlv19174", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f8047d0f-fd7f-4cd1-a199-62ef50463692"}}}}, {"uuid": "184974a9-5002-4bab-bace-c579e696241d", "name": "", "x": 38.659792348994905, "y": -122.43853929357995, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8b9386f2-376d-4439-a9a4-3eefc238dafe", "name": "p1rdm19776", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "184974a9-5002-4bab-bace-c579e696241d"}}}}, {"uuid": "97d3a98b-859b-4c49-9814-8854ec2c9ea8", "name": "", "x": 38.659815187445474, "y": -122.43766561018224, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "50750ddb-80db-4d5f-bc62-4bbfc600a7ef", "name": "p1rlv19184", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "97d3a98b-859b-4c49-9814-8854ec2c9ea8"}}}}, {"uuid": "6760425d-5a9c-4a69-a620-335a6a50dd5a", "name": "", "x": 38.66094193321756, "y": -122.4420778873007, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be2777cc-f3fd-491f-a10b-4ed381cb948d", "name": "p1rdt8905lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6760425d-5a9c-4a69-a620-335a6a50dd5a"}}}}, {"uuid": "e4fb0dbb-9f87-44eb-8fc2-c6fa5b3b190c", "name": "", "x": 38.66079928545388, "y": -122.4418071207425, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be4e8183-9148-477e-aa1b-ff31a5324273", "name": "p1rlv19169", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e4fb0dbb-9f87-44eb-8fc2-c6fa5b3b190c"}}}}, {"uuid": "cdebdf2f-ce8a-4206-9a08-febb53cf2595", "name": "", "x": 38.66134282316126, "y": -122.44240057565185, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fffe26f7-c4cc-420e-ab17-754cb0d9e659", "name": "p1rlv19171", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cdebdf2f-ce8a-4206-9a08-febb53cf2595"}}}}, {"uuid": "a3f6aa7b-1b7e-4b4c-99f6-ba8b0c163e86", "name": "", "x": 38.661324142709425, "y": -122.44226279573506, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "21fec301-b67c-4042-a074-caf406c7f0b5", "name": "p1rlv19173", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a3f6aa7b-1b7e-4b4c-99f6-ba8b0c163e86"}}}}, {"uuid": "e1a509d5-5978-458c-b5a3-4a6ad7aa48bb", "name": "", "x": 38.660891099685436, "y": -122.44216271154556, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "47e24942-486d-46f1-a40f-0da5c93c013a", "name": "p1rlv19188", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e1a509d5-5978-458c-b5a3-4a6ad7aa48bb"}}}}, {"uuid": "8daf8c62-fb93-452e-a50f-f20fd4575028", "name": "", "x": 38.660438772467124, "y": -122.44179842559906, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d7daa1d3-6249-447d-a260-65de5ec0a470", "name": "p1rlv19194", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8daf8c62-fb93-452e-a50f-f20fd4575028"}}}}, {"uuid": "f5014d04-b09d-4eb3-ab03-0922624e3ed6", "name": "", "x": 38.65966647434038, "y": -122.44177391418427, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c306f79a-0240-465e-a486-d0f11614fc57", "name": "p1rdt8911lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5014d04-b09d-4eb3-ab03-0922624e3ed6"}}}}, {"uuid": "ef46d329-2e90-4650-bdbe-4d60014873d6", "name": "", "x": 38.659762694003604, "y": -122.44175769963816, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "89bde057-807b-415c-9135-267c6bf43c44", "name": "p1rlv19183", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef46d329-2e90-4650-bdbe-4d60014873d6"}}}}, {"uuid": "f91d9e6c-5898-4087-987a-3ebafb3c94ca", "name": "", "x": 38.659528505871954, "y": -122.44178250448644, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4a8ae6dc-884d-48d8-9995-fe3936ad019c", "name": "p1rlv20296", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f91d9e6c-5898-4087-987a-3ebafb3c94ca"}}}}, {"uuid": "0edbaaa4-6519-455b-9246-8a1c2a9156ca", "name": "", "x": 38.66174426844995, "y": -122.44236029493588, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2fbbca23-6473-4344-ac2e-cc97078b3d8d", "name": "p1rdt8915lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0edbaaa4-6519-455b-9246-8a1c2a9156ca"}}}}, {"uuid": "6b82329d-8f91-4a11-af20-f5eea8feb9c7", "name": "", "x": 38.66176977524987, "y": -122.44231719933447, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5fecc64a-4783-4ecb-a0d0-7e60d1cf6184", "name": "p1rlv19189", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6b82329d-8f91-4a11-af20-f5eea8feb9c7"}}}}, {"uuid": "9b3f7497-3003-404d-b677-bcdb323c6ab4", "name": "", "x": 38.66022824513094, "y": -122.4403032002883, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d268e33-708d-4bae-8348-cad27fd0d81a", "name": "p1rdt8916lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9b3f7497-3003-404d-b677-bcdb323c6ab4"}}}}, {"uuid": "04b52ef4-71da-4abc-bfca-23d50fefdad0", "name": "", "x": 38.66024260770121, "y": -122.44035400544816, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4aee02d4-8663-455b-a197-55b6b1470895", "name": "p1rlv19190", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "04b52ef4-71da-4abc-bfca-23d50fefdad0"}}}}, {"uuid": "3a99f762-bf86-47c2-a9c5-ba32b79116be", "name": "", "x": 38.655203793367576, "y": -122.45620231524185, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6752e8f4-9e37-476d-aec2-4a2fe7c1e2dc", "name": "p1rdt9075lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3a99f762-bf86-47c2-a9c5-ba32b79116be"}}}}, {"uuid": "2f6f79fa-c192-4f73-8fe9-34244be1e20a", "name": "", "x": 38.65518999754597, "y": -122.45625337194336, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33dcb037-4cc8-480f-aac4-bc95e54e165e", "name": "p1rlv19667", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2f6f79fa-c192-4f73-8fe9-34244be1e20a"}}}}, {"uuid": "18e29a87-cfae-409d-a4d0-59cdfda79164", "name": "", "x": 38.659371136386014, "y": -122.45366040420096, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bdd64386-e256-47f8-8cef-1c933f993a29", "name": "p1rdt9076lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "18e29a87-cfae-409d-a4d0-59cdfda79164"}}}}, {"uuid": "510bb7b0-5542-41e1-85d9-ab5f40613641", "name": "", "x": 38.65966620569122, "y": -122.45316394323339, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "14b1ab4e-b22d-4a98-8131-fc72c923c735", "name": "p1rlv19698", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "510bb7b0-5542-41e1-85d9-ab5f40613641"}}}}, {"uuid": "12fed0c5-f799-4023-b80f-43c58a88eefd", "name": "", "x": 38.65923252263959, "y": -122.45353105574254, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fd00c91a-01a8-4aad-b740-b06a654d631b", "name": "p1rdm20204", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "12fed0c5-f799-4023-b80f-43c58a88eefd"}}}}, {"uuid": "6ba53ded-0201-4663-a8a2-5703783675ba", "name": "", "x": 38.65913430903858, "y": -122.45372718962375, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6427f66-2e22-40bb-83f1-2a8b1be9191a", "name": "p1rlv19668", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6ba53ded-0201-4663-a8a2-5703783675ba"}}}}, {"uuid": "7a201e5f-5a2b-4c99-866d-0b8445ce2f1e", "name": "", "x": 38.659402236788104, "y": -122.45320795008209, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48654a82-ac11-4542-94ec-8f731138e1a8", "name": "p1rlv19699", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7a201e5f-5a2b-4c99-866d-0b8445ce2f1e"}}}}, {"uuid": "3219c596-244a-4592-ac08-1498542b882a", "name": "", "x": 38.65946805558687, "y": -122.45379361501921, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ce8f50bb-90fb-49b8-8a16-1bbbb6a0c82c", "name": "p1rdm20205", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3219c596-244a-4592-ac08-1498542b882a"}}}}, {"uuid": "8c0543e4-bfd1-4ea1-abd8-9f20075a02f4", "name": "", "x": 38.65960231517979, "y": -122.45359720642892, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "47f5777d-2c8d-48c2-bf28-386f3f3dbac4", "name": "p1rlv19686", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8c0543e4-bfd1-4ea1-abd8-9f20075a02f4"}}}}, {"uuid": "61eb89b7-5c68-4fe6-a2cf-65b8a9334552", "name": "", "x": 38.652242872397366, "y": -122.46144885825713, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6b83eaaa-a092-42ca-a746-db4d9658d62b", "name": "p1rdt9077lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "61eb89b7-5c68-4fe6-a2cf-65b8a9334552"}}}}, {"uuid": "d2c378d1-16dd-475a-96e9-e684db274429", "name": "", "x": 38.65239205276167, "y": -122.4611909367415, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "96d3079a-02f1-4c89-ad75-fd0a438c9cf4", "name": "p1rlv19669", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d2c378d1-16dd-475a-96e9-e684db274429"}}}}, {"uuid": "955a59ba-ed77-4cb8-ba64-6835fb9101a6", "name": "", "x": 38.65223106297542, "y": -122.46145646522658, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0031ab1b-d82d-40a5-b41e-bc6f6cb53069", "name": "p1rlv19675", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "955a59ba-ed77-4cb8-ba64-6835fb9101a6"}}}}, {"uuid": "54b6622c-d1f3-4f49-9fe9-b34c2b16e965", "name": "", "x": 38.65203392082483, "y": -122.46169927854602, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35fe21a1-f817-426e-9e42-f1f33876dd7d", "name": "p1rlv19695", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "54b6622c-d1f3-4f49-9fe9-b34c2b16e965"}}}}, {"uuid": "52222e5e-929d-40e5-9033-af986edf0e1c", "name": "", "x": 38.658511634388226, "y": -122.45377906068661, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7f0e4f59-8a46-4abf-9f06-e0383a59a45d", "name": "p1rdt9084lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "52222e5e-929d-40e5-9033-af986edf0e1c"}}}}, {"uuid": "7d2fecb9-f2e2-4813-bc4a-f2dd44b73ae1", "name": "", "x": 38.65890081567661, "y": -122.4539013635132, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "83afc678-d577-4ef1-afa2-8e3f915a158b", "name": "p1rlv19681", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7d2fecb9-f2e2-4813-bc4a-f2dd44b73ae1"}}}}, {"uuid": "87d5d0d0-3503-4fb3-90d4-b7010024e8e1", "name": "", "x": 38.65082653264708, "y": -122.46112619224643, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "565bbfb1-a28f-4db2-be48-cbd58972025a", "name": "p1rdt9085lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "87d5d0d0-3503-4fb3-90d4-b7010024e8e1"}}}}, {"uuid": "024c67e1-26f2-4e2d-a9e1-2363314f620e", "name": "", "x": 38.65123799892708, "y": -122.46107316768796, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "811acd48-b61c-4a42-b76e-f995961c450e", "name": "p1rlv19682", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "024c67e1-26f2-4e2d-a9e1-2363314f620e"}}}}, {"uuid": "e9eeb7a0-71f8-42f2-8fde-92047b07a318", "name": "", "x": 38.650795641302004, "y": -122.46090410093127, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ec27727b-2bb8-4df2-9ddf-46282728c2c0", "name": "p1rdm20223", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e9eeb7a0-71f8-42f2-8fde-92047b07a318"}}}}, {"uuid": "0e0f0e38-cf93-421d-b57f-3480c11f4488", "name": "", "x": 38.65132742554806, "y": -122.46092309986851, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1b5d936f-b3e0-408e-aabd-d3ebb7b869b0", "name": "p1rlv19701", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0e0f0e38-cf93-421d-b57f-3480c11f4488"}}}}, {"uuid": "f408d815-1e53-4979-87cd-e7df5fb7d70f", "name": "", "x": 38.65246361026913, "y": -122.46218753579743, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f8108ac8-2807-4a40-85c2-db21efaadadb", "name": "p1rdt9089lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f408d815-1e53-4979-87cd-e7df5fb7d70f"}}}}, {"uuid": "35ae0831-567f-4d28-ba9e-19a634226d71", "name": "", "x": 38.65247796334516, "y": -122.46223833997352, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "578b5df8-1dd8-41d9-b6dc-db75db5b115e", "name": "p1rlv19689", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "35ae0831-567f-4d28-ba9e-19a634226d71"}}}}, {"uuid": "7fb01aed-5f5d-4a4a-8919-592230ce46fe", "name": "", "x": 38.65140101826137, "y": -122.46336158947928, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6fc84159-09b1-4ca9-9a7a-a4fecab19f83", "name": "p1rdt9090lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7fb01aed-5f5d-4a4a-8919-592230ce46fe"}}}}, {"uuid": "67c1af07-75b2-4ed0-80c3-3d37cc36508d", "name": "", "x": 38.651714420003884, "y": -122.4627704444441, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e2709a70-1a7d-454c-90fd-377e416a0071", "name": "p1rlv19690", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "67c1af07-75b2-4ed0-80c3-3d37cc36508d"}}}}, {"uuid": "b8912d59-aeda-43db-8f27-552d50bb9d26", "name": "", "x": 38.650846513531, "y": -122.46155124895908, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1e93ea18-150d-4d80-bac7-f3e1b87c5b4e", "name": "p1rdt9091lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b8912d59-aeda-43db-8f27-552d50bb9d26"}}}}, {"uuid": "ff33634d-a59f-408c-ac9f-96661327410f", "name": "", "x": 38.65126752046812, "y": -122.4616130767133, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b10b272a-2efb-4e19-9921-d4081fb45778", "name": "p1rlv19692", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ff33634d-a59f-408c-ac9f-96661327410f"}}}}, {"uuid": "43134dcc-0533-4dab-bdbd-171362ac4a36", "name": "", "x": 38.65985495091543, "y": -122.45426942925806, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2f0726b7-3050-4c78-9c06-b9fd0c863ff3", "name": "p1rdt9093lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "43134dcc-0533-4dab-bdbd-171362ac4a36"}}}}, {"uuid": "80050a7c-ddcb-47cd-bd59-7f16d2859412", "name": "", "x": 38.65961615387016, "y": -122.45463151295169, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "37f72c85-61f7-4a42-94b0-6a627195458c", "name": "p1rlv19702", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "80050a7c-ddcb-47cd-bd59-7f16d2859412"}}}}, {"uuid": "f4631a44-4de8-418b-94ae-9e7331f02e3b", "name": "", "x": 38.629339299867084, "y": -122.45270506395599, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1c01a9b2-b002-4279-905e-950452f64f32", "name": "p1rdt9264lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f4631a44-4de8-418b-94ae-9e7331f02e3b"}}}}, {"uuid": "27ed1f16-03eb-42ce-8702-a73fa474132f", "name": "", "x": 38.629416853696135, "y": -122.45255114958653, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aaea76fa-797e-46c5-a70f-a973977db841", "name": "p1rlv20064", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "27ed1f16-03eb-42ce-8702-a73fa474132f"}}}}, {"uuid": "881403a8-f760-42b5-8e71-49adf089ec98", "name": "", "x": 38.629219943787845, "y": -122.4528398621658, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ea48ffa1-bdb3-4c15-96c9-ff7d7f34824f", "name": "p1rlv20065", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "881403a8-f760-42b5-8e71-49adf089ec98"}}}}, {"uuid": "b4544aa4-b735-4c64-84e5-139bf0f516a2", "name": "", "x": 38.62682787398021, "y": -122.443538396124, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "77d62813-61d3-4afd-9f21-869e2ea23e17", "name": "p1rdt9265lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b4544aa4-b735-4c64-84e5-139bf0f516a2"}}}}, {"uuid": "d260b95e-211c-4042-a884-17ace9831ea6", "name": "", "x": 38.626801885358226, "y": -122.44349579157367, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f450eeb4-3d87-4ae5-a6d6-958d7efd2712", "name": "p1rlv20066", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d260b95e-211c-4042-a884-17ace9831ea6"}}}}, {"uuid": "88a974e9-a865-4c00-8ffc-1e39aa989a25", "name": "", "x": 38.63354009061449, "y": -122.4470022329432, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "78278589-be2d-4d99-9c03-92c221348917", "name": "p1rdt9266lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "88a974e9-a865-4c00-8ffc-1e39aa989a25"}}}}, {"uuid": "0c7edbb5-8c60-4dd4-8097-98444bf41092", "name": "", "x": 38.6335544502105, "y": -122.44705302069676, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "66a710fb-26c7-4465-b7ea-43ec107008dc", "name": "p1rlv20067", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0c7edbb5-8c60-4dd4-8097-98444bf41092"}}}}, {"uuid": "59e72f91-e9dd-4f26-9cdd-f72aaafbf0b6", "name": "", "x": 38.57668432917656, "y": -122.5244581272183, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "208f222c-45db-445f-ba0b-a4a195ca68a6", "name": "p1rdt9298lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59e72f91-e9dd-4f26-9cdd-f72aaafbf0b6"}}}}, {"uuid": "af9dc8ee-cee4-460f-9c97-b2613c61e390", "name": "", "x": 38.57703900731173, "y": -122.52455160092381, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ffc82be6-f3f8-4a68-b6e6-da60b137329c", "name": "p1rlv20130", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "af9dc8ee-cee4-460f-9c97-b2613c61e390"}}}}, {"uuid": "4d3a48b7-fd17-4c40-ad5a-1107322e7fa2", "name": "", "x": 38.57648055489435, "y": -122.52532048800711, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "180fad26-0e7d-4e2c-ba17-c8e3315ca278", "name": "p1rdt9302lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d3a48b7-fd17-4c40-ad5a-1107322e7fa2"}}}}, {"uuid": "55752a53-a905-418a-94b6-4741fc94dd93", "name": "", "x": 38.57700673397096, "y": -122.52548171913072, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d635a151-2d13-47e9-8043-a214415a5b5e", "name": "p1rlv20138", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "55752a53-a905-418a-94b6-4741fc94dd93"}}}}, {"uuid": "6be69bf2-e2da-4ffd-8e12-9ecb59720f76", "name": "", "x": 38.57718617464166, "y": -122.52237333536553, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d4940a0e-dcc2-45fb-baa9-aadc84f8e882", "name": "p1rdt9310lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6be69bf2-e2da-4ffd-8e12-9ecb59720f76"}}}}, {"uuid": "ab4905b9-4e99-49bb-a83d-8bfaa642964a", "name": "", "x": 38.576705284221035, "y": -122.5222692278727, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9d615e93-a289-41ec-bda0-3b72bf15677e", "name": "p1rlv20146", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ab4905b9-4e99-49bb-a83d-8bfaa642964a"}}}}, {"uuid": "95a5439a-0a5c-4f7b-ae08-bed7b34b0ecf", "name": "", "x": 38.57637456989155, "y": -122.51922519254137, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b9e0aa7d-9097-4370-8f5e-52a5885da85c", "name": "p1rdt9311lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "95a5439a-0a5c-4f7b-ae08-bed7b34b0ecf"}}}}, {"uuid": "85a764e0-e69e-45dc-8957-3b9ca0ab1fd3", "name": "", "x": 38.576279327246795, "y": -122.51948236126216, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16b2add7-6a6d-4359-ad6f-f60edf435a4c", "name": "p1rlv20147", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "85a764e0-e69e-45dc-8957-3b9ca0ab1fd3"}}}}, {"uuid": "88a233ee-71b3-424d-a3b1-cf5eb54ab2a0", "name": "", "x": 38.57622563406502, "y": -122.51957456046857, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e938635b-e0d2-4e1b-a312-5a8f51e1dd7a", "name": "p1rlv20163", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "88a233ee-71b3-424d-a3b1-cf5eb54ab2a0"}}}}, {"uuid": "252394b9-5e80-462d-b1ad-93684148d1b5", "name": "", "x": 38.57944374835563, "y": -122.52129067940982, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0a21f5ca-51ef-4f81-8229-163182f011cf", "name": "p1rdt9312lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "252394b9-5e80-462d-b1ad-93684148d1b5"}}}}, {"uuid": "f1070023-ce6c-4a46-a28b-44adc0b27a78", "name": "", "x": 38.579207205820964, "y": -122.52143752839837, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a4a0c2f2-f75e-4c9c-b3f7-d8d9ada9cb82", "name": "p1rlv20148", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f1070023-ce6c-4a46-a28b-44adc0b27a78"}}}}, {"uuid": "0c82b69e-699d-4e19-95a1-17d14b7c7c9b", "name": "", "x": 38.57963859321071, "y": -122.52114764756729, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "27dfea92-734e-49d3-b245-dc933df66889", "name": "p1rlv20160", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0c82b69e-699d-4e19-95a1-17d14b7c7c9b"}}}}, {"uuid": "aa912d24-a8bb-448b-a77f-ee94b50f811c", "name": "", "x": 38.57499954420577, "y": -122.51877161682458, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3df13d91-365e-411b-917d-b28df5989280", "name": "p1rdt9314lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aa912d24-a8bb-448b-a77f-ee94b50f811c"}}}}, {"uuid": "03254f1e-f392-4daf-802c-1b58ee985315", "name": "", "x": 38.57488526903181, "y": -122.5194726576567, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3eb214b9-827f-4995-a862-907be02b029d", "name": "p1rlv20473", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "03254f1e-f392-4daf-802c-1b58ee985315"}}}}, {"uuid": "99be95b3-5b0a-4a25-88ec-b2a960507eeb", "name": "", "x": 38.57479824917913, "y": -122.51872307044951, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d5930295-0e44-4498-ae22-7647b72c1fa1", "name": "p1rdm20686", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "99be95b3-5b0a-4a25-88ec-b2a960507eeb"}}}}, {"uuid": "fa40295b-b2bc-4dca-a1a5-18c69a4d7b10", "name": "", "x": 38.574765880638516, "y": -122.5196187229471, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "956f4975-7383-4e0b-9114-d333a6ec4005", "name": "p1rlv20151", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa40295b-b2bc-4dca-a1a5-18c69a4d7b10"}}}}, {"uuid": "842bddbc-e3f4-415c-9892-b5c663d506b7", "name": "", "x": 38.57481830117202, "y": -122.51921657510196, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a7a43aa6-2be8-4320-8089-57d388633c6b", "name": "p1rlv20456", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "842bddbc-e3f4-415c-9892-b5c663d506b7"}}}}, {"uuid": "b7d25399-f31a-4e49-adba-a78ff86c5b8b", "name": "", "x": 38.57661532605132, "y": -122.51941521089782, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8c97a99f-545b-49cd-b1fe-4fd9e04bf37f", "name": "p1rdt9316lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b7d25399-f31a-4e49-adba-a78ff86c5b8b"}}}}, {"uuid": "be71b6c1-afc0-467f-8b9b-c08c14272f70", "name": "", "x": 38.57645998524856, "y": -122.51958447974425, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ef20846d-d685-4c65-8dfb-bc23317501c5", "name": "p1rlv20153", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be71b6c1-afc0-467f-8b9b-c08c14272f70"}}}}, {"uuid": "2a99897f-364d-411e-8bbe-72f557ebc745", "name": "", "x": 38.6051181986353, "y": -122.47354850924762, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a68a1c01-a04c-4af6-b1c8-02ddd1d67e0b", "name": "p1rdt9333lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2a99897f-364d-411e-8bbe-72f557ebc745"}}}}, {"uuid": "de597ed3-ec97-4454-aed4-09dd7a03ce13", "name": "", "x": 38.605233794489806, "y": -122.47322379683654, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "20f93381-3834-4265-b1ec-5767d171ce0a", "name": "p1rlv20182", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "de597ed3-ec97-4454-aed4-09dd7a03ce13"}}}}, {"uuid": "c9d78551-0fd5-43ed-8b68-579cb2336594", "name": "", "x": 38.589035386079345, "y": -122.51706377791538, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e98299cb-8bad-49ea-8627-f3cfe01b9e23", "name": "p1rdt9377lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c9d78551-0fd5-43ed-8b68-579cb2336594"}}}}, {"uuid": "d490540a-d433-41f2-b9e7-eca6fa93417a", "name": "", "x": 38.58906092117887, "y": -122.51702075225897, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fb7a8747-a076-469c-a150-35f6763157ec", "name": "p1rlv20277", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d490540a-d433-41f2-b9e7-eca6fa93417a"}}}}, {"uuid": "26eb7692-c5a5-4207-b2ef-2f5b4fc9f7de", "name": "", "x": 38.554956569072154, "y": -122.5078416303234, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9e37f182-5a60-470d-8f5b-ba145cc27973", "name": "p1rdt9381lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "26eb7692-c5a5-4207-b2ef-2f5b4fc9f7de"}}}}, {"uuid": "cff5bde2-44fa-4d0e-a743-f67d7e951b2c", "name": "", "x": 38.55506084687392, "y": -122.50759593781095, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3f23405b-432f-45ff-a7b1-0b7147cddfc8", "name": "p1rlv20281", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cff5bde2-44fa-4d0e-a743-f67d7e951b2c"}}}}, {"uuid": "095f699d-7656-4788-95ba-fb5548a06de8", "name": "", "x": 38.55481960527157, "y": -122.50809108490742, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9e5718ad-0b70-4ea4-b2f2-31f0ea5c5d5b", "name": "p1rlv20309", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "095f699d-7656-4788-95ba-fb5548a06de8"}}}}, {"uuid": "afabc397-de9a-4321-856d-b35e976cd844", "name": "", "x": 38.658604016675696, "y": -122.44126850823349, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "abd09ea6-221c-47d9-beec-1062e0dd4aa7", "name": "p1rdt9384lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "afabc397-de9a-4321-856d-b35e976cd844"}}}}, {"uuid": "fbc5a56d-565b-4454-b6d6-7d72d0bfe51f", "name": "", "x": 38.65866093691784, "y": -122.4412720400857, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25837ab0-0fb8-4346-94ad-561ff9ff7f0c", "name": "p1rlv20284", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fbc5a56d-565b-4454-b6d6-7d72d0bfe51f"}}}}, {"uuid": "1d71f24e-2901-42c3-a813-a3acd99d09c3", "name": "", "x": 38.55588955861104, "y": -122.50676017270496, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fc7e0a25-d6d6-4b07-b3dc-4fe5646915e2", "name": "p1rdt9396lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d71f24e-2901-42c3-a813-a3acd99d09c3"}}}}, {"uuid": "25e2bcaf-cac0-4e8f-91e9-d28d24280f7e", "name": "", "x": 38.55589072497332, "y": -122.5068140409716, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "da62d78e-e221-423a-8da0-8d36ce1f7508", "name": "p1rlv20300", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "25e2bcaf-cac0-4e8f-91e9-d28d24280f7e"}}}}, {"uuid": "1b4f1d5d-7d2c-437f-90c6-9aa0e49f8009", "name": "", "x": 38.62027530963716, "y": -122.47939957508689, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8180ee90-a46e-4d85-9742-d47b24f5e169", "name": "p1rdt9413lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1b4f1d5d-7d2c-437f-90c6-9aa0e49f8009"}}}}, {"uuid": "9fc146a4-e41f-4cf3-b41f-4854efeea77d", "name": "", "x": 38.62004720247463, "y": -122.47879011072362, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c23afdc0-ab93-4d43-8eec-613eab21cd74", "name": "p1rlv20333", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9fc146a4-e41f-4cf3-b41f-4854efeea77d"}}}}, {"uuid": "02cb45f3-fe94-4dd8-9573-6a0f478a879c", "name": "", "x": 38.620529773744515, "y": -122.47990087956352, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4b5d2dfa-895b-4afc-a7fe-449960adba41", "name": "p1rlv20358", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "02cb45f3-fe94-4dd8-9573-6a0f478a879c"}}}}, {"uuid": "e94a07cf-e35c-478c-a311-9ca498f5c3ae", "name": "", "x": 38.591063428696835, "y": -122.52153986948501, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a015abb-ec63-4b31-9314-283b8499646e", "name": "p1rdt9463lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e94a07cf-e35c-478c-a311-9ca498f5c3ae"}}}}, {"uuid": "25620ccf-e94e-4be9-bfe7-91878762980d", "name": "", "x": 38.59108896543552, "y": -122.52149684417888, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e4b5327a-85a3-496c-859c-f887a38513cd", "name": "p1rlv20432", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "25620ccf-e94e-4be9-bfe7-91878762980d"}}}}, {"uuid": "cca09bca-16e9-499c-b095-0c1950ecc547", "name": "", "x": 38.57979403494598, "y": -122.51418658341599, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4dbe1628-cd17-4f37-af2b-dd752c290fa4", "name": "p1rdt9468lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cca09bca-16e9-499c-b095-0c1950ecc547"}}}}, {"uuid": "e157a12b-a7d2-4147-bcd2-b3ab3a70ddae", "name": "", "x": 38.57980836535011, "y": -122.514237347121, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c37708d8-1e83-4e76-ac7f-0d29ba6b7c4e", "name": "p1rlv20451", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e157a12b-a7d2-4147-bcd2-b3ab3a70ddae"}}}}, {"uuid": "f80fb467-df08-4b12-85da-2108e641dcd6", "name": "", "x": 38.64987390299784, "y": -122.46561468579733, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "09613257-d4cb-4c50-b35a-8aefc637c0c9", "name": "p1rdt9469lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f80fb467-df08-4b12-85da-2108e641dcd6"}}}}, {"uuid": "a8be240d-00b9-4f9d-adf9-0f1168744f6a", "name": "", "x": 38.649915988400906, "y": -122.4656103988514, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a4e21b79-d2be-4a53-be46-32331e61f89c", "name": "p1rlv20453", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8be240d-00b9-4f9d-adf9-0f1168744f6a"}}}}, {"uuid": "8860d0ef-e55e-447d-93df-ae60d3936aa0", "name": "", "x": 38.65045746320294, "y": -122.46638434729005, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1ab8727-2758-4513-8a7d-e02381faf1e4", "name": "p1rdt9470lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8860d0ef-e55e-447d-93df-ae60d3936aa0"}}}}, {"uuid": "057230d4-bf01-4042-ad61-30c7db0f897e", "name": "", "x": 38.650379000628085, "y": -122.46634293498136, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9dfcfdbf-0051-4eef-bea6-97446cee21e4", "name": "p1rlv20459", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "057230d4-bf01-4042-ad61-30c7db0f897e"}}}}, {"uuid": "5cf1438a-80c4-4c22-aaed-3469743e85b4", "name": "", "x": 38.65057767311801, "y": -122.46643339731892, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9af153ed-ed39-4433-ac12-19dfdb7b6bef", "name": "p1rlv20499", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5cf1438a-80c4-4c22-aaed-3469743e85b4"}}}}, {"uuid": "7b65f4e9-580d-47dc-b34e-28f81d668390", "name": "", "x": 38.56377829551582, "y": -122.5132715911584, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c14c3211-a0d5-464f-820c-cab04764d907", "name": "p1rdt9473lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7b65f4e9-580d-47dc-b34e-28f81d668390"}}}}, {"uuid": "8a3e10a2-8282-43c8-b4da-fda1b1669c94", "name": "", "x": 38.5639962321023, "y": -122.51298713404236, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4759390d-43ec-45c9-9cca-320020dc1150", "name": "p1rlv20465", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8a3e10a2-8282-43c8-b4da-fda1b1669c94"}}}}, {"uuid": "cb26fbb7-596c-4de9-b34e-101dc678ca65", "name": "", "x": 38.5746780928461, "y": -122.51786998579286, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6a8f268-6a5a-4b23-bd91-53c6b031442a", "name": "p1rdt9479lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb26fbb7-596c-4de9-b34e-101dc678ca65"}}}}, {"uuid": "e39e8d8e-0d46-4628-94c5-07b594071e7e", "name": "", "x": 38.574723226995864, "y": -122.51801181420616, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cacd3e49-55aa-4f05-bd7d-ae8aba0af87f", "name": "p1rlv20502", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e39e8d8e-0d46-4628-94c5-07b594071e7e"}}}}, {"uuid": "7c12f6c5-55e6-49d1-bd94-2352ee3b1586", "name": "", "x": 38.65513908341776, "y": -122.34387958999741, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ac361065-6b3c-4ac6-96d5-9b474eb3b80f", "name": "p1rdt16638lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7c12f6c5-55e6-49d1-bd94-2352ee3b1586"}}}}, {"uuid": "0207b470-cf6d-4629-9b3c-ad531fda5dab", "name": "", "x": 38.655190554276075, "y": -122.34392111738993, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aa4eed95-33b7-4827-8744-52d14149b386", "name": "p1rlv38126", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0207b470-cf6d-4629-9b3c-ad531fda5dab"}}}}, {"uuid": "533bb500-770c-4d2c-9cc1-28775d01f44e", "name": "", "x": 38.65630824124314, "y": -122.34286109532569, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bae9a352-584d-4cf0-9ebd-eb280b684e78", "name": "p1rdt16725lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "533bb500-770c-4d2c-9cc1-28775d01f44e"}}}}, {"uuid": "ff5a7ad7-1d65-4c62-8ae0-267a310fb193", "name": "", "x": 38.65627492173817, "y": -122.34284238795301, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6cbb9976-253c-4863-899f-9218c4496688", "name": "p1rlv38269", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ff5a7ad7-1d65-4c62-8ae0-267a310fb193"}}}}, {"uuid": "f8eacce3-9525-4b06-8b1b-f7019fa7c45f", "name": "", "x": 38.62034621533613, "y": -122.43765627693834, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6bfb33cd-0cf1-455d-81e7-3d0472fa1b41", "name": "p1rdt8012", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f8eacce3-9525-4b06-8b1b-f7019fa7c45f"}}}}, {"uuid": "804049e0-ce7b-491e-99fa-e410e6a6a3be", "name": "", "x": 38.618246403950295, "y": -122.43508018831336, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e261b565-1f57-4cdc-bdd6-e045ee55d290", "name": "p1rdt7983", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "804049e0-ce7b-491e-99fa-e410e6a6a3be"}}}}, {"uuid": "6bfa5767-f2b2-4c1a-99b7-7b23d5fb2141", "name": "", "x": 38.620540310627334, "y": -122.43796845936235, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3f83d22a-fa1e-4a4e-aab9-a9dea8ee06e5", "name": "p1rdt8034", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6bfa5767-f2b2-4c1a-99b7-7b23d5fb2141"}}}}, {"uuid": "d27b544e-9687-455f-ba58-9ed436c5a572", "name": "", "x": 38.622378075951055, "y": -122.4397117047474, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "21e15d54-eab8-4204-9ed6-407fd8684700", "name": "p1rdt7954", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d27b544e-9687-455f-ba58-9ed436c5a572"}}}}, {"uuid": "81d253a0-1d96-4c57-8981-717e38dcce21", "name": "", "x": 38.62277584721677, "y": -122.43997282390552, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "016e4575-cd41-4993-be9b-5e5236a139ae", "name": "p1rdt7973", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "81d253a0-1d96-4c57-8981-717e38dcce21"}}}}, {"uuid": "4d3f203c-47be-4223-8720-2528ecc712e5", "name": "", "x": 38.62402950921016, "y": -122.44277403473237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ea481f8-b9c7-4067-9bfb-4f7cdc5dee15", "name": "p1rdt5172", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d3f203c-47be-4223-8720-2528ecc712e5"}}}}, {"uuid": "0e03e381-7790-4e61-94b7-9d458b302a4d", "name": "", "x": 38.62300895388021, "y": -122.44290656824234, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16712e10-4c7f-428b-917b-135ab3c2d4b3", "name": "p1rdt5155", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0e03e381-7790-4e61-94b7-9d458b302a4d"}}}}, {"uuid": "bf821b66-093f-4603-ad7e-32bed64b35bc", "name": "", "x": 38.623287659052096, "y": -122.4427643158668, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "afc636ed-f90c-4c48-822b-e86890d36f3b", "name": "p1rdt5155-p1rdt5172x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bf821b66-093f-4603-ad7e-32bed64b35bc"}}}}, {"uuid": "0363d42a-c376-4ae4-8b0d-bb484444fee6", "name": "", "x": 38.623116980624474, "y": -122.4447782161465, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9c289632-ba52-4b65-b6da-ac76b1477246", "name": "p1rdt5201", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0363d42a-c376-4ae4-8b0d-bb484444fee6"}}}}, {"uuid": "840097f5-3c7a-4849-b762-f137bdea4c16", "name": "", "x": 38.62329628881549, "y": -122.44457929911667, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ee606236-08d7-4258-96c9-e9104f15b467", "name": "p1rdt5159-p1rdt5201x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "840097f5-3c7a-4849-b762-f137bdea4c16"}}}}, {"uuid": "7f834bdd-4114-42ce-9e63-53bc785fec0a", "name": "", "x": 38.6234306387608, "y": -122.44440819183146, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "90fb2270-4759-4779-80c1-7f93d66e1c53", "name": "p1rdt5159", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7f834bdd-4114-42ce-9e63-53bc785fec0a"}}}}, {"uuid": "37141299-89a0-41ed-982a-51081d6b3d42", "name": "", "x": 38.62215863028796, "y": -122.44620579183537, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "86d3f96e-ffe2-459f-a2f1-b63d7bf138b8", "name": "p1rdt5180-p1rdt5201x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "37141299-89a0-41ed-982a-51081d6b3d42"}}}}, {"uuid": "6e4501c1-afa6-454f-bb4e-7186b7feb938", "name": "", "x": 38.615444643589946, "y": -122.4340993039006, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6fec8a81-a151-4d8f-adc7-6d6d87d7759f", "name": "p1rdt5923", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6e4501c1-afa6-454f-bb4e-7186b7feb938"}}}}, {"uuid": "da1cc01b-26a4-4326-b5b2-37141fb8691d", "name": "", "x": 38.61722132993687, "y": -122.42939704924423, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "14b429c3-41da-4123-b661-40cbdfaf33e0", "name": "p1rdt8346", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "da1cc01b-26a4-4326-b5b2-37141fb8691d"}}}}, {"uuid": "5a082e29-1507-4b02-b095-69b11f571dda", "name": "", "x": 38.617041139275344, "y": -122.43743292025952, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48e4b67a-0a47-48f0-b787-0a639db89caa", "name": "p1rdt7988", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5a082e29-1507-4b02-b095-69b11f571dda"}}}}, {"uuid": "4ed19a51-3310-41a4-aff9-28d8a46ca419", "name": "", "x": 38.62223049910566, "y": -122.44617598691588, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "893d2436-cd6c-40ad-90af-64ba1ac23f6e", "name": "p1rdt5180-p1rdt7988x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ed19a51-3310-41a4-aff9-28d8a46ca419"}}}}, {"uuid": "43402875-9dea-4473-be24-75b831aa6d6f", "name": "", "x": 38.62337315716766, "y": -122.45650688359399, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0089e5ea-d706-4a74-812f-654ae73eabcf", "name": "p1rdt8456", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "43402875-9dea-4473-be24-75b831aa6d6f"}}}}, {"uuid": "4cea5a72-5bb5-4f43-8eda-1ef360771178", "name": "", "x": 38.62156927448908, "y": -122.45679446794591, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "13b8cfc1-d8eb-4f47-b024-c1daacf3771d", "name": "p1rdt8447", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4cea5a72-5bb5-4f43-8eda-1ef360771178"}}}}, {"uuid": "cb3e167d-c2cb-4736-8f66-8143d56bd1cf", "name": "", "x": 38.6238198104542, "y": -122.456272029401, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "34054ef8-8942-4471-ac14-43c6a37e5a16", "name": "p1rdt8414-p1rdt8456x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb3e167d-c2cb-4736-8f66-8143d56bd1cf"}}}}, {"uuid": "8cb1f65f-d4fc-4d14-9857-6d98b2cc3094", "name": "", "x": 38.610218492856475, "y": -122.45635700104502, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8a53624b-8538-4cce-b588-c774875af31b", "name": "p1rdt6274", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8cb1f65f-d4fc-4d14-9857-6d98b2cc3094"}}}}, {"uuid": "fdc5de1c-ebb2-4bff-8945-795a93fc75f8", "name": "", "x": 38.61055108690851, "y": -122.4555659540378, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3ac93b23-1041-486e-a16e-861082c92f35", "name": "p1rdt6272-p1rdt6274x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fdc5de1c-ebb2-4bff-8945-795a93fc75f8"}}}}, {"uuid": "e57a56c3-8dcc-4aa1-91fc-48c8b8f06c8e", "name": "", "x": 38.610520720245056, "y": -122.45545884146962, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "034bda10-d48e-449c-9255-247cbf718683", "name": "p1rdt6272", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e57a56c3-8dcc-4aa1-91fc-48c8b8f06c8e"}}}}, {"uuid": "c16f990c-0ff1-414b-8380-ee7d791b0f96", "name": "", "x": 38.61197078011171, "y": -122.45741942756798, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0a75c5e2-2277-42b4-87d4-6eadff5c06f1", "name": "p1rdt6271", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c16f990c-0ff1-414b-8380-ee7d791b0f96"}}}}, {"uuid": "2dd1c6fe-9e94-4b4a-97e5-0fe2f1fb7e6d", "name": "", "x": 38.61207637689822, "y": -122.45737706222091, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "28954596-f060-4fa8-9f13-dfaa633bb739", "name": "p1rdt6270-p1rdt6271xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2dd1c6fe-9e94-4b4a-97e5-0fe2f1fb7e6d"}}}}, {"uuid": "0ca652d0-115a-441c-8eb8-5cf8c840706d", "name": "", "x": 38.6128563737481, "y": -122.45907473259327, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "898611f5-c343-4cca-8e5e-60cf0bfd796b", "name": "p1rdt6270-p1rdt6271xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0ca652d0-115a-441c-8eb8-5cf8c840706d"}}}}, {"uuid": "496b5d51-e112-464a-bb9c-4049894d8dee", "name": "", "x": 38.613028815797925, "y": -122.45946476660588, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b81bd5c2-96bb-445e-9eb8-d72360fd8a94", "name": "p1rdt6270-p1rdt6271xxxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "496b5d51-e112-464a-bb9c-4049894d8dee"}}}}, {"uuid": "d05a1a5c-0920-4097-babd-b5923ba0ddbd", "name": "", "x": 38.603726878082334, "y": -122.46288947925576, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "76f6a27f-0e4f-48b8-9dbd-31c6ffc4ec75", "name": "p1rdt7579", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d05a1a5c-0920-4097-babd-b5923ba0ddbd"}}}}, {"uuid": "417b978b-18e3-4121-a1bf-51f957cfd9dd", "name": "", "x": 38.60179587168076, "y": -122.46429351511154, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fa33ca9e-e16d-4c49-8a70-c6c30cf7b038", "name": "p1rdt7564", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "417b978b-18e3-4121-a1bf-51f957cfd9dd"}}}}, {"uuid": "38d20a1b-d399-4ab6-bf7c-aae66fa23a4c", "name": "", "x": 38.601539075146476, "y": -122.46251347070827, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8f2dabc2-0b52-490c-b13a-32c268f6bd33", "name": "p1rdt7588", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "38d20a1b-d399-4ab6-bf7c-aae66fa23a4c"}}}}, {"uuid": "4e241cc8-3082-4fd0-88d1-fc267588d21d", "name": "", "x": 38.60742474012847, "y": -122.4582846144434, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0f6de990-0988-4126-86ca-d1fd72c555fe", "name": "p1rdt7554", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4e241cc8-3082-4fd0-88d1-fc267588d21d"}}}}, {"uuid": "9b8ba534-6195-4b35-89f5-2a4c3c722bf4", "name": "", "x": 38.607801140709334, "y": -122.45761981019629, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2bdb2b51-0526-4995-bb5e-a2bd495488d4", "name": "p1rdt7554-p1rdt7570x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9b8ba534-6195-4b35-89f5-2a4c3c722bf4"}}}}, {"uuid": "4c45e384-de6e-47e6-a9ad-b6aae63c720c", "name": "", "x": 38.607753208324574, "y": -122.4554757397103, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f239ef4e-83f0-4a2c-ada3-8e30cef38472", "name": "p1rdt7559", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c45e384-de6e-47e6-a9ad-b6aae63c720c"}}}}, {"uuid": "3156fc94-96bd-4a53-b84b-3ddb7c65c545", "name": "", "x": 38.60740955675949, "y": -122.45440672587179, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ff343735-753a-48ca-92b1-ea778c9e0b5c", "name": "p1rdt7559-p1rdt8015x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3156fc94-96bd-4a53-b84b-3ddb7c65c545"}}}}, {"uuid": "e810c55c-bf24-40b9-8584-0ea6ba45bdd3", "name": "", "x": 38.60632927470628, "y": -122.45140187652409, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cc543f54-740b-4a7f-b1c5-eb3783a8ade0", "name": "p1rdt8015", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e810c55c-bf24-40b9-8584-0ea6ba45bdd3"}}}}, {"uuid": "7bf553bc-03a7-4134-b7e6-ce6194ed1aad", "name": "", "x": 38.60785880448065, "y": -122.45543337407624, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "09814176-7891-4fe1-addf-b47aa106c40d", "name": "p1rdt7559-p1rdt7570xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7bf553bc-03a7-4134-b7e6-ce6194ed1aad"}}}}, {"uuid": "2a3f447c-2df8-43bd-98a5-56059107b4e9", "name": "", "x": 38.607591729699735, "y": -122.45675980389136, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1dbec6c9-5c87-4f56-bd92-4a30d39ad094", "name": "p1rdt7559-p1rdt7570x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2a3f447c-2df8-43bd-98a5-56059107b4e9"}}}}, {"uuid": "3e452e28-6a28-4350-8544-cdbfbe2a921a", "name": "", "x": 38.601892868535366, "y": -122.45542862865831, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "db899c48-a801-4f83-b59d-e587ba80019d", "name": "p1rdt7552", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e452e28-6a28-4350-8544-cdbfbe2a921a"}}}}, {"uuid": "373ec05f-2d67-4736-8ebe-e41faea4f4ff", "name": "", "x": 38.60005814605219, "y": -122.4516448455036, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "93a5388e-ffd7-403e-b6cf-26b7e81feed1", "name": "p1rdt7986", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "373ec05f-2d67-4736-8ebe-e41faea4f4ff"}}}}, {"uuid": "fb5c1be3-22fd-4000-8e6b-267de4b40db1", "name": "", "x": 38.60314520391628, "y": -122.45852350850332, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2f0f3112-1395-48bf-88c1-8dd4b171478d", "name": "p1rdt7551", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fb5c1be3-22fd-4000-8e6b-267de4b40db1"}}}}, {"uuid": "928e2eec-1973-4044-bad0-d4fcdf464563", "name": "", "x": 38.60020849529689, "y": -122.46072753146206, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fc6bd64f-1ad3-4bd9-b590-7d4b673a94b5", "name": "p1rdt7561", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "928e2eec-1973-4044-bad0-d4fcdf464563"}}}}, {"uuid": "1741a3e1-3d98-4b45-9891-d9daf0f8513c", "name": "", "x": 38.60111102829196, "y": -122.46101936494843, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dead8520-e2f5-499b-9316-77780f9b1dfe", "name": "p1rdt7550", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1741a3e1-3d98-4b45-9891-d9daf0f8513c"}}}}, {"uuid": "af4f08f0-94de-4726-88ae-e00fcd4eaa36", "name": "", "x": 38.597594406004944, "y": -122.45741331498996, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f28de397-0db4-486a-8ce6-9f65c68703b3", "name": "p1rdt8434", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "af4f08f0-94de-4726-88ae-e00fcd4eaa36"}}}}, {"uuid": "45dc3818-21a6-4584-80fc-2019452cf93a", "name": "", "x": 38.597440760670644, "y": -122.45596586818255, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "184f95d4-cde1-4bf1-8a74-ebc7097cb10e", "name": "p1rdt8450", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "45dc3818-21a6-4584-80fc-2019452cf93a"}}}}, {"uuid": "799600d7-d852-4c9b-8f6e-1102fdded8ce", "name": "", "x": 38.597703329969455, "y": -122.45880555075607, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bbfe31b1-38ce-4ae4-9143-bf08c81617e8", "name": "p1rdt8440", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "799600d7-d852-4c9b-8f6e-1102fdded8ce"}}}}, {"uuid": "44c7d264-7191-4b9e-acb0-88e311db57b3", "name": "", "x": 38.59658206909063, "y": -122.45932321062192, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "516ca275-0d8e-4a9a-ab59-89cb66b95d93", "name": "p1rdt8436-p1rdt8440x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "44c7d264-7191-4b9e-acb0-88e311db57b3"}}}}, {"uuid": "9df146b4-516e-4ea5-bda7-c1a73ae15633", "name": "", "x": 38.59579222604902, "y": -122.46002037573007, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fcc42825-2690-4965-a99b-e78285a9b84e", "name": "p1rdt8436", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9df146b4-516e-4ea5-bda7-c1a73ae15633"}}}}, {"uuid": "c6913b29-d9ba-47a3-a192-1193e7e5403c", "name": "", "x": 38.596573779354905, "y": -122.45753186177956, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5f6e9b43-ceca-4a80-9569-696375a6ff5b", "name": "p1rdt8440-p1rdt8444x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c6913b29-d9ba-47a3-a192-1193e7e5403c"}}}}, {"uuid": "0a73aed7-d223-4038-9ac0-5b92a4d1987c", "name": "", "x": 38.5957635117617, "y": -122.45709408297363, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "685fbdbf-47af-4cc2-97ce-354dd04ce915", "name": "p1rdt8444", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a73aed7-d223-4038-9ac0-5b92a4d1987c"}}}}, {"uuid": "bf112380-b4c4-4738-a1d4-d798c1f01364", "name": "", "x": 38.599951855708426, "y": -122.46051919867074, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c0075333-98fe-4ee8-bb64-a18119b817c0", "name": "p1rdt7555", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bf112380-b4c4-4738-a1d4-d798c1f01364"}}}}, {"uuid": "f068e58c-2e16-4f15-8bf8-2f3eae98f96a", "name": "", "x": 38.601199336202434, "y": -122.46001207089114, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1e068b84-fbff-4546-b708-ca91ffe92b69", "name": "p1rdt7551-p1rdt7561x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f068e58c-2e16-4f15-8bf8-2f3eae98f96a"}}}}, {"uuid": "5cb7897b-26e3-4fb1-8110-0c2b58852939", "name": "", "x": 38.60649944562754, "y": -122.45751394231347, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1d8c14d0-8247-4a44-98c1-4534aa9037a2", "name": "p1rdt7551-p1rdt7574x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5cb7897b-26e3-4fb1-8110-0c2b58852939"}}}}, {"uuid": "7080975e-bc07-4286-ac0c-b487ce747aa8", "name": "", "x": 38.60635191905131, "y": -122.45581093557001, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ddf629eb-ea60-4fce-b731-7ebb33665829", "name": "p1rdt7553", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7080975e-bc07-4286-ac0c-b487ce747aa8"}}}}, {"uuid": "ece1113e-bcd2-4196-a2a1-14453f132e65", "name": "", "x": 38.606309626265485, "y": -122.45581243510644, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d4307e78-304a-4175-8e81-9cb23d99f394", "name": "p1rdt7572", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ece1113e-bcd2-4196-a2a1-14453f132e65"}}}}, {"uuid": "cbdc1d01-82c3-4ee4-babc-404553de25e5", "name": "", "x": 38.60642288565036, "y": -122.45576012137332, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f00dd033-8e7c-43af-bd16-1de2954e07be", "name": "p1rdt7553-p1rdt7574xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cbdc1d01-82c3-4ee4-babc-404553de25e5"}}}}, {"uuid": "c187bbb9-4399-4b90-a4f6-ea17d84c91b1", "name": "", "x": 38.60650133107034, "y": -122.45676802538416, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7744d8d9-73a8-4274-9c91-5542620942f5", "name": "p1rdt7553-p1rdt7574x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c187bbb9-4399-4b90-a4f6-ea17d84c91b1"}}}}, {"uuid": "e6eab6d5-ecec-4a44-9135-ace4449f9a3f", "name": "", "x": 38.616823684704634, "y": -122.45485169561282, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a9722136-480b-44cb-8b0e-0b3165712688", "name": "p1rdt5179-p1rdt6273x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e6eab6d5-ecec-4a44-9135-ace4449f9a3f"}}}}, {"uuid": "cbcad839-30cf-45d7-8aeb-5541d365147b", "name": "", "x": 38.61884536658003, "y": -122.45181991735679, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d22f1247-b756-4498-8cf8-fef7d1e859ff", "name": "p1rdt5179", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cbcad839-30cf-45d7-8aeb-5541d365147b"}}}}, {"uuid": "32980d01-7147-4efb-9208-6924bc7a6c36", "name": "", "x": 38.620392420969665, "y": -122.45625723062152, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "28af960e-6f27-483a-8029-0c5f1641f51d", "name": "p1rdt8408", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "32980d01-7147-4efb-9208-6924bc7a6c36"}}}}, {"uuid": "6eb63711-311c-48b0-a200-7708a569b3be", "name": "", "x": 38.62105939691115, "y": -122.45567255802798, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "433162b1-2a9b-4187-ba28-ec57503d76f6", "name": "p1rdt8458", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6eb63711-311c-48b0-a200-7708a569b3be"}}}}, {"uuid": "34790c46-d3a6-4ef4-a144-f8aa7791f306", "name": "", "x": 38.61794197262064, "y": -122.4571451861387, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "07f340ca-58c2-4331-8265-a39a45c87b75", "name": "p1rdt8439", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "34790c46-d3a6-4ef4-a144-f8aa7791f306"}}}}, {"uuid": "2882cbbd-35ac-40a5-8eba-2fa1353c5ab1", "name": "", "x": 38.619657499896064, "y": -122.45651946734527, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3430524c-820d-4f17-ba1b-377aeef4bbcd", "name": "p1rdt8408-p1rdt8439x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2882cbbd-35ac-40a5-8eba-2fa1353c5ab1"}}}}, {"uuid": "950056a4-f77d-43ed-abc8-f0ebb5f1eacf", "name": "", "x": 38.61643197384722, "y": -122.45750913060422, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "19d5304c-574f-4646-8095-d2dcbbea86e7", "name": "p1rdt6278-p1rdt8439x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "950056a4-f77d-43ed-abc8-f0ebb5f1eacf"}}}}, {"uuid": "46372221-c5d6-4e25-9937-70ae8e4a5744", "name": "", "x": 38.61757719949048, "y": -122.46073569903709, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a8c69243-872f-4e25-9d03-82692bbf8779", "name": "p1rdt8405-p1rdt8445x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "46372221-c5d6-4e25-9937-70ae8e4a5744"}}}}, {"uuid": "0193f084-2414-465f-8507-c518ab5551df", "name": "", "x": 38.61750461268671, "y": -122.46257773961285, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1e3ecdca-4b27-4a9d-8599-637924e86602", "name": "p1rdt8405-p1rdt8445xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0193f084-2414-465f-8507-c518ab5551df"}}}}, {"uuid": "559151e0-4417-49f0-a82d-3d35634b96df", "name": "", "x": 38.61747453032813, "y": -122.46077804087776, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bc0ee90f-1f9e-435e-bac4-86a4688c48fc", "name": "p1rdt8445", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "559151e0-4417-49f0-a82d-3d35634b96df"}}}}, {"uuid": "bd56f243-69e2-4d25-88e4-d5062a621ab9", "name": "", "x": 38.58085055283345, "y": -122.50956971443162, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bf648a0d-3262-4150-892b-55c3b117050a", "name": "p1rdt6500-p1rdt6519xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bd56f243-69e2-4d25-88e4-d5062a621ab9"}}}}, {"uuid": "4f978e8c-71c9-4108-8bd4-dd7e04c67d03", "name": "", "x": 38.58085769734513, "y": -122.50951590453553, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5789c3b2-eb91-4e4c-85e8-24f5893e1a2c", "name": "p1rdt6500-p1rdt6519xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4f978e8c-71c9-4108-8bd4-dd7e04c67d03"}}}}, {"uuid": "1a89ad58-99e8-48ca-b84d-4d30890fd198", "name": "", "x": 38.580324139975936, "y": -122.51120115232804, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c0824c21-244b-4d4e-85d6-238ac4908b5a", "name": "p1rdt6505-p1rdt6508x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1a89ad58-99e8-48ca-b84d-4d30890fd198"}}}}, {"uuid": "a9ea404f-0da3-492e-ad2b-10b63708892f", "name": "", "x": 38.57943061458019, "y": -122.51076650882104, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eb1c1e50-902d-443d-8c9a-b728d2f6b6f1", "name": "p1rdt6505", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a9ea404f-0da3-492e-ad2b-10b63708892f"}}}}, {"uuid": "845aaad9-1218-47c7-8b04-b96551dfcf6b", "name": "", "x": 38.57967511307611, "y": -122.5126018254279, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "66b7b2e9-7658-4de0-8197-3829c6179353", "name": "p1rdt6510-p1rdt6523x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "845aaad9-1218-47c7-8b04-b96551dfcf6b"}}}}, {"uuid": "0aa3f3d5-e5aa-42de-9954-8117a443544a", "name": "", "x": 38.57908668009848, "y": -122.5112130456528, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "848c04de-e4d5-4520-9dce-0073776c2ae4", "name": "p1rdt6510", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0aa3f3d5-e5aa-42de-9954-8117a443544a"}}}}, {"uuid": "80fce609-371e-4216-a76f-a73c72f53ba1", "name": "", "x": 38.57473976942866, "y": -122.51780959626444, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e07d8bc1-2f8a-4067-a2a7-b903dd042ce3", "name": "p1rdt5730-p1rdt9479x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "80fce609-371e-4216-a76f-a73c72f53ba1"}}}}, {"uuid": "ae73743c-8548-4137-a180-59f6280b9424", "name": "", "x": 38.57217576563056, "y": -122.51803280458198, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d5897bb2-1f72-4aeb-9090-74e2411b5786", "name": "p1rdt5730", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ae73743c-8548-4137-a180-59f6280b9424"}}}}, {"uuid": "ae5a3785-7653-4bf5-8675-35a3db35f092", "name": "", "x": 38.5747498946316, "y": -122.51790816237944, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e7f9286b-4209-402a-a365-1d27da4efb75", "name": "p1rdt5840-p1rdt9479x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ae5a3785-7653-4bf5-8675-35a3db35f092"}}}}, {"uuid": "693261a2-e33f-420e-98d7-aba12afe2b54", "name": "", "x": 38.57341254858641, "y": -122.51993371906103, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35722d90-049e-4c67-9654-acce0572e6c2", "name": "p1rdt5840", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "693261a2-e33f-420e-98d7-aba12afe2b54"}}}}, {"uuid": "a649e8d5-4a5d-4cc5-af0e-8100bd84e39b", "name": "", "x": 38.576726073438714, "y": -122.52446579115181, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "61ba1001-8b9d-481c-b205-45c6e0beadc1", "name": "p1rdt9298", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a649e8d5-4a5d-4cc5-af0e-8100bd84e39b"}}}}, {"uuid": "5ef16793-c098-41e2-b98c-4f9e4e7eefc7", "name": "", "x": 38.576522299104546, "y": -122.52532815241987, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f4a41fe9-62ce-45ba-abcd-086ba429baa0", "name": "p1rdt9302", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ef16793-c098-41e2-b98c-4f9e4e7eefc7"}}}}, {"uuid": "1dc016b2-4413-4089-9171-3916a1d89cab", "name": "", "x": 38.57714443025326, "y": -122.52236567259841, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3035d22c-c39f-4f07-9fe9-29888b16057d", "name": "p1rdt9310", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1dc016b2-4413-4089-9171-3916a1d89cab"}}}}, {"uuid": "b7ae5a8f-66ef-4d60-9134-78c031712321", "name": "", "x": 38.57657358147667, "y": -122.51940754990198, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "644c5887-31f1-436c-bbf6-dae5a70743a2", "name": "p1rdt9316", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b7ae5a8f-66ef-4d60-9134-78c031712321"}}}}, {"uuid": "8efefa1d-8ecd-4c4d-9e24-01b27035c531", "name": "", "x": 38.57940200391493, "y": -122.5212830170439, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b8721684-5439-482c-b8e5-be330d3cf745", "name": "p1rdt9312", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8efefa1d-8ecd-4c4d-9e24-01b27035c531"}}}}, {"uuid": "f194676e-4380-4328-ab02-daf91a9df474", "name": "", "x": 38.57641631447873, "y": -122.5192328534116, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7011f1dc-1e7d-4961-9a23-620b7f5737af", "name": "p1rdt9311", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f194676e-4380-4328-ab02-daf91a9df474"}}}}, {"uuid": "b9a6ab8a-47b8-4813-b138-81c932fd688f", "name": "", "x": 38.57548870286482, "y": -122.51882223524302, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "95d939ff-e20d-42b3-bb88-f1975f9fa0aa", "name": "p1rdt6518-p1rdt9311x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b9a6ab8a-47b8-4813-b138-81c932fd688f"}}}}, {"uuid": "659d0d06-e371-4b97-a79c-b5e43f8c7802", "name": "", "x": 38.56957251351933, "y": -122.5146506475286, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "77d2122b-cbb7-4844-bbb2-55e939431e50", "name": "p1rdt5729", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "659d0d06-e371-4b97-a79c-b5e43f8c7802"}}}}, {"uuid": "491c68dc-d6da-48bf-ae44-2d31c3d9cc06", "name": "", "x": 38.569500663957065, "y": -122.51470628390435, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "52f308f4-35db-49ec-a599-f8380489f952", "name": "p1rdt5729-p1rdt5731x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "491c68dc-d6da-48bf-ae44-2d31c3d9cc06"}}}}, {"uuid": "73967e47-18f3-483a-b10a-771124b63d48", "name": "", "x": 38.56683955344907, "y": -122.51476612858174, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "95cd61cf-f1cb-4af2-9d3b-e42978642003", "name": "p1rdt5731", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "73967e47-18f3-483a-b10a-771124b63d48"}}}}, {"uuid": "c7c257cd-2ea4-4e0e-9bb1-7f376fac96bf", "name": "", "x": 38.57065927664959, "y": -122.51444197635051, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b55c58cf-153e-4aa3-b099-8a1db05a6ae5", "name": "p1rdt5728", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c7c257cd-2ea4-4e0e-9bb1-7f376fac96bf"}}}}, {"uuid": "8ca253b4-42a5-4f7b-a94f-f26b95862d14", "name": "", "x": 38.57561216943165, "y": -122.51516613679155, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "66ef2ffb-e67d-47eb-ae59-194c538ab861", "name": "p1rdt5728-p1rdt6537x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8ca253b4-42a5-4f7b-a94f-f26b95862d14"}}}}, {"uuid": "34dad3c6-ccba-4a06-b54f-a9247d0f4c5f", "name": "", "x": 38.579768071852676, "y": -122.5141439807202, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9b5695dd-714e-4de1-a63a-f142ff0460e1", "name": "p1rdt9468", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "34dad3c6-ccba-4a06-b54f-a9247d0f4c5f"}}}}, {"uuid": "90fe05b7-f3d0-4489-a2c8-35e8cb9c8b41", "name": "", "x": 38.58086149565407, "y": -122.51897714369541, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e6348d4-7fcb-4546-af84-8ece75b6332f", "name": "p1rdt6502", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "90fe05b7-f3d0-4489-a2c8-35e8cb9c8b41"}}}}, {"uuid": "24c5be44-0224-48e1-b290-3d4953eec426", "name": "", "x": 38.580154407405615, "y": -122.51201736754072, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ddfa01c0-4d12-4f96-ab50-0082ef9914a6", "name": "p1rdt6501-p1rdt9468x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "24c5be44-0224-48e1-b290-3d4953eec426"}}}}, {"uuid": "93db63be-461c-4dab-8933-25baf8c11b03", "name": "", "x": 38.58045994181232, "y": -122.51074519698878, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7e4fd2ed-daa1-4a22-936f-8d51ee928d99", "name": "p1rdt6501-p1rdt9468x_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "93db63be-461c-4dab-8933-25baf8c11b03"}}}}, {"uuid": "10535ec6-eb7b-492e-a01d-5671139f021b", "name": "", "x": 38.58028290845341, "y": -122.51146113028999, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "42f09ae1-037a-4565-9cd2-0187c45b7866", "name": "p1rdt6509-p1rdt6514x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10535ec6-eb7b-492e-a01d-5671139f021b"}}}}, {"uuid": "0679c775-bf98-4471-bcd1-d965416cb97f", "name": "", "x": 38.580317644679276, "y": -122.51149205289134, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0737f6ec-0d5d-4cff-b4b7-9910c7076984", "name": "p1rdt6514", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0679c775-bf98-4471-bcd1-d965416cb97f"}}}}, {"uuid": "ecc88ed7-fb40-4552-8972-44bc465197f2", "name": "", "x": 38.57914402812339, "y": -122.51052209118085, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60b93cd6-c9fc-46ef-8b37-6b14d0773df6", "name": "p1rdt6498-p1rdt6516x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ecc88ed7-fb40-4552-8972-44bc465197f2"}}}}, {"uuid": "36242e7c-2807-441f-bc4d-826953103893", "name": "", "x": 38.578899383271626, "y": -122.51078551451845, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f5c5466f-b7e4-4844-967b-9e8b11c68b44", "name": "p1rdt6498", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "36242e7c-2807-441f-bc4d-826953103893"}}}}, {"uuid": "0317cab2-2dea-4ee4-9adb-5d6193ef7f1b", "name": "", "x": 38.566808328998086, "y": -122.50026076244916, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1f6ad7d-f7ea-4b94-956c-ec4a3b2028d5", "name": "p1rdt7298-p1rdt7313x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0317cab2-2dea-4ee4-9adb-5d6193ef7f1b"}}}}, {"uuid": "7eb6d4fd-b3a0-4a74-bd1c-256d42ed5872", "name": "", "x": 38.56643827491598, "y": -122.50011683345299, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b658bf21-450c-4e6b-9dec-c5023a05fd19", "name": "p1rdt7298", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7eb6d4fd-b3a0-4a74-bd1c-256d42ed5872"}}}}, {"uuid": "a581d35a-62ba-4b17-881e-badaf252f4fd", "name": "", "x": 38.56306630294141, "y": -122.50758361380268, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "28d17238-8db8-41da-960c-317183423576", "name": "p1rdt7036-p1rdt7091xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a581d35a-62ba-4b17-881e-badaf252f4fd"}}}}, {"uuid": "52b1a853-b828-4e73-b319-cc93eab563e6", "name": "", "x": 38.56354447960164, "y": -122.50839891620973, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "770cf0ab-50f1-489b-b2ea-d23ba186d10b", "name": "p1rdt7036-p1rdt7091x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "52b1a853-b828-4e73-b319-cc93eab563e6"}}}}, {"uuid": "54e92f2f-4588-4cda-9b5f-6f20e3c81165", "name": "", "x": 38.56300711787946, "y": -122.50763349737177, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "52068090-b613-46d7-a31f-ad3ca26382d5", "name": "p1rdt7036", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "54e92f2f-4588-4cda-9b5f-6f20e3c81165"}}}}, {"uuid": "3a0dbb41-c169-4ec0-8293-06ea239c1640", "name": "", "x": 38.562803482644604, "y": -122.51371079164413, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "97be7ac3-a710-4de8-a666-276813582cd6", "name": "p1rdt7620", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3a0dbb41-c169-4ec0-8293-06ea239c1640"}}}}, {"uuid": "b5ba243f-bb48-42fc-9d16-bfcab7c4716d", "name": "", "x": 38.56262386822574, "y": -122.51386121629318, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5bddd75e-1974-41ee-ab51-625c7485a573", "name": "p1rdt7627", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b5ba243f-bb48-42fc-9d16-bfcab7c4716d"}}}}, {"uuid": "e16bdb71-55c9-4a8f-8864-3327a56f5392", "name": "", "x": 38.56326190620687, "y": -122.51262082119965, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b3a4dfb4-e1b3-43b9-ae42-b0cec47ff4ad", "name": "p1rdt7311", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e16bdb71-55c9-4a8f-8864-3327a56f5392"}}}}, {"uuid": "4837ebc1-7a64-454a-95d7-ad5dc94def01", "name": "", "x": 38.56382004055108, "y": -122.51327924731947, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e4d8bafa-711d-4fd7-8374-7eeaeb43edcd", "name": "p1rdt9473", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4837ebc1-7a64-454a-95d7-ad5dc94def01"}}}}, {"uuid": "d1d35578-3675-44f4-b9e5-3512fa60f90f", "name": "", "x": 38.56294875123604, "y": -122.51180445263074, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "607c7275-da9a-4620-b019-59a66e98c2e6", "name": "p1rdt7306", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1d35578-3675-44f4-b9e5-3512fa60f90f"}}}}, {"uuid": "aa3b4b1d-2dd2-46e6-b28d-96be15961943", "name": "", "x": 38.5622926191724, "y": -122.5122220982717, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "56d67e3e-46af-4e2c-86a8-191d97b0ce8a", "name": "p1rdt7626", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aa3b4b1d-2dd2-46e6-b28d-96be15961943"}}}}, {"uuid": "8d521c86-54cb-4653-b5c6-8d9cae9e2cb8", "name": "", "x": 38.56302679357027, "y": -122.51026940176808, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3a65c4d3-2fc6-48c8-b944-68c4229db3dd", "name": "p1rdt7302", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8d521c86-54cb-4653-b5c6-8d9cae9e2cb8"}}}}, {"uuid": "a9e57660-7319-4bfc-a3d2-fcf715fdcfa9", "name": "", "x": 38.56309662911135, "y": -122.5097294573527, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "01c9d31d-c3bb-4950-9bbd-00377c252ddc", "name": "p1rdt7617", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a9e57660-7319-4bfc-a3d2-fcf715fdcfa9"}}}}, {"uuid": "c255184c-f2ed-4139-8383-2022a4b54427", "name": "", "x": 38.56316201817732, "y": -122.50953508538782, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a11cf3d9-90bb-4de8-b637-6ec9128525ec", "name": "p1rdt7617-p1rdt7625x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c255184c-f2ed-4139-8383-2022a4b54427"}}}}, {"uuid": "467d86b5-04a7-4310-966c-b874fd20f77e", "name": "", "x": 38.56129645031688, "y": -122.51025818859465, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "723e2b5c-414c-4f3d-ba23-d2df4bc63e75", "name": "p1rdt7630", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "467d86b5-04a7-4310-966c-b874fd20f77e"}}}}, {"uuid": "6edb6e11-ef87-458b-9e88-98c9e94188dc", "name": "", "x": 38.56190962697, "y": -122.51114576371964, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c7167a2e-9e83-441e-a15b-0256848c3f6d", "name": "p1rdt7616", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6edb6e11-ef87-458b-9e88-98c9e94188dc"}}}}, {"uuid": "b03f4ed4-9c9d-4423-9868-5308cb6b1368", "name": "", "x": 38.56171870357492, "y": -122.50994542040628, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aa48cf27-3b07-4460-ad9c-8d9862238645", "name": "p1rdt7621", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b03f4ed4-9c9d-4423-9868-5308cb6b1368"}}}}, {"uuid": "f92f9ef8-f56e-4f46-aa51-c53171f745c3", "name": "", "x": 38.56318612934499, "y": -122.50945665578503, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "53df7b6e-bd8c-43f2-860d-8869aec5d079", "name": "p1rdt7621-p1rdt7625x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f92f9ef8-f56e-4f46-aa51-c53171f745c3"}}}}, {"uuid": "7cf7bb6c-4bb7-464a-be3a-91cd2396461f", "name": "", "x": 38.55823465883282, "y": -122.50730279853406, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "08d3a02a-555d-4ad1-9b13-d413b7a16eef", "name": "p1rdt7090", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7cf7bb6c-4bb7-464a-be3a-91cd2396461f"}}}}, {"uuid": "3cc41f38-ab18-423e-8f7c-520e94039dcb", "name": "", "x": 38.558375802568776, "y": -122.50792515178091, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3cf406b-69e6-4aee-a6fc-272dad7693a4", "name": "p1rdt7054", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3cc41f38-ab18-423e-8f7c-520e94039dcb"}}}}, {"uuid": "685168bc-7964-448d-9c19-26d528fd2eae", "name": "", "x": 38.55914097308907, "y": -122.50637841432136, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aae22557-7d34-401d-82c9-2d2710ff2915", "name": "p1rdt7069", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "685168bc-7964-448d-9c19-26d528fd2eae"}}}}, {"uuid": "cfab6ae3-c499-4fe4-bd80-17d2c1ba2a07", "name": "", "x": 38.55990008450235, "y": -122.50687823607828, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f614382d-3883-4f6b-b1f6-c8e83d84ee22", "name": "p1rdt7087", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cfab6ae3-c499-4fe4-bd80-17d2c1ba2a07"}}}}, {"uuid": "73e43a9d-07db-47c1-94a1-988b0a844d27", "name": "", "x": 38.561212075777895, "y": -122.50733192344723, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8cebb186-4d9e-4d2c-b0d9-100056d34942", "name": "p1rdt7075", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "73e43a9d-07db-47c1-94a1-988b0a844d27"}}}}, {"uuid": "e987d9bf-0536-4244-9f47-a482bed25baa", "name": "", "x": 38.56134985808187, "y": -122.50795078492914, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "662e2a1c-9a54-4ac3-b478-98e3a478349d", "name": "p1rdt7080", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e987d9bf-0536-4244-9f47-a482bed25baa"}}}}, {"uuid": "db51b889-2677-4f16-9c3d-ee199f25a1a3", "name": "", "x": 38.56137014768056, "y": -122.50849010412762, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "161d6f3b-8bd9-4fa8-9442-c6ff008e8d3d", "name": "p1rdt7619", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "db51b889-2677-4f16-9c3d-ee199f25a1a3"}}}}, {"uuid": "c1c279b4-65c1-4732-a079-66f1aa2a03a9", "name": "", "x": 38.56077220663575, "y": -122.5085365470598, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "105df8ff-ec38-4cd6-b557-c318b4023bd0", "name": "p1rdt7615", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c1c279b4-65c1-4732-a079-66f1aa2a03a9"}}}}, {"uuid": "f337a156-4901-495b-b237-6edff9890775", "name": "", "x": 38.561738481750105, "y": -122.50901203752454, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b9e53141-a773-4127-9558-3887070a8f36", "name": "p1rdt7631", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f337a156-4901-495b-b237-6edff9890775"}}}}, {"uuid": "5ffbe342-0944-4873-987b-e7b8ca04bcbb", "name": "", "x": 38.56310083575031, "y": -122.50950410932236, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "460f5de9-8d4f-468a-b67a-b3b05354a9ce", "name": "p1rdt7625-p1rdt7631x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ffbe342-0944-4873-987b-e7b8ca04bcbb"}}}}, {"uuid": "4a433241-8ed9-4429-92a8-1ce38f0ba622", "name": "", "x": 38.5810553987312, "y": -122.5094376679452, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fec078c2-a5d8-4317-a8ac-bc25772f6358", "name": "p1rdt6515-p1rdt6535xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4a433241-8ed9-4429-92a8-1ce38f0ba622"}}}}, {"uuid": "d74595fc-2533-48bd-a6b5-323641953b72", "name": "", "x": 38.58105426448104, "y": -122.50949283188041, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f5a05d0e-8cf2-4ab8-bdfd-24b8cd12ad67", "name": "p1rdt6515-p1rdt6535xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d74595fc-2533-48bd-a6b5-323641953b72"}}}}, {"uuid": "5e32b2a0-a40b-4f7a-b599-26082e03f999", "name": "", "x": 38.58100676420751, "y": -122.50921942626415, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "04c1e05a-9cbb-4e53-9412-1cffd3976bed", "name": "p1rdt6515-p1rdt6536xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5e32b2a0-a40b-4f7a-b599-26082e03f999"}}}}, {"uuid": "f6d2dfe0-3d18-4c2c-b520-52cbb246dd08", "name": "", "x": 38.58098452673457, "y": -122.50917228702704, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5aa6899b-19a2-41e6-b445-f9fe2536c8d9", "name": "p1rdt6515-p1rdt6536xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f6d2dfe0-3d18-4c2c-b520-52cbb246dd08"}}}}, {"uuid": "995470a2-9f55-4576-97e3-0af02bcc170b", "name": "", "x": 38.58182522217373, "y": -122.50873063816502, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d21061fa-1011-44f7-8a20-26fcf0550f52", "name": "p1rdt8901-p1rdt8902x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "995470a2-9f55-4576-97e3-0af02bcc170b"}}}}, {"uuid": "1974122e-33d7-4966-a35c-5e21f25bdbb4", "name": "", "x": 38.581260006183335, "y": -122.50726033751013, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f23ab51c-56f3-4421-b66e-7cdcf109787d", "name": "p1rdt8901", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1974122e-33d7-4966-a35c-5e21f25bdbb4"}}}}, {"uuid": "6a6c8e90-6c34-4143-ae2d-51c7114ee9e2", "name": "", "x": 38.589021563154894, "y": -122.51711477621102, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "61972a50-ce24-4ec1-8535-402665b55a55", "name": "p1rdt9377", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a6c8e90-6c34-4143-ae2d-51c7114ee9e2"}}}}, {"uuid": "007ab400-5c36-4d26-ae49-7a6f16f74ac6", "name": "", "x": 38.58692523202436, "y": -122.52017146759988, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "84200441-4c26-4966-a4b7-6b91fb43f02e", "name": "p1rdt7301", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "007ab400-5c36-4d26-ae49-7a6f16f74ac6"}}}}, {"uuid": "bffa8083-006e-415c-b5d9-eb6a34928792", "name": "", "x": 38.581769930879894, "y": -122.50871878720857, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "43c862de-b014-4b24-8b34-54dae6edcf5a", "name": "p1rdt8902-p1rdt9377x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bffa8083-006e-415c-b5d9-eb6a34928792"}}}}, {"uuid": "de4f5afd-459e-4cbf-aa49-cd504cb83abb", "name": "", "x": 38.5814032621987, "y": -122.50967321866453, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32e86968-974e-4bcc-b562-1d4209771cf0", "name": "p1rdt8902-p1rdt9377x_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "de4f5afd-459e-4cbf-aa49-cd504cb83abb"}}}}, {"uuid": "6a742844-a654-453e-919e-80445d759442", "name": "", "x": 38.59300712782786, "y": -122.52139582849708, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "37c41a4b-e439-42a1-b9a7-0582c528f0e5", "name": "p1rdt8490", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a742844-a654-453e-919e-80445d759442"}}}}, {"uuid": "b6439b84-94cd-405b-b7ee-069f0c9d898c", "name": "", "x": 38.59104960383041, "y": -122.5215908683816, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "271ab023-4425-40d8-8080-2481c71309b5", "name": "p1rdt9463", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b6439b84-94cd-405b-b7ee-069f0c9d898c"}}}}, {"uuid": "39925f06-fa1e-450f-95b8-ba4e101482e4", "name": "", "x": 38.59323212584656, "y": -122.52027519448441, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "307d9c6d-d5ee-4490-95d3-5a9b1d171e54", "name": "p1rdt8492", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "39925f06-fa1e-450f-95b8-ba4e101482e4"}}}}, {"uuid": "39bd7fbf-764d-4497-aaba-76a78b273ff5", "name": "", "x": 38.59334183117795, "y": -122.52026098011822, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "605c34bc-3f7c-4eb7-8df0-fcd00d261921", "name": "p1rdt7599-p1rdt8492x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "39bd7fbf-764d-4497-aaba-76a78b273ff5"}}}}, {"uuid": "f5319190-a0b2-4d37-9550-a0f2b572bf96", "name": "", "x": 38.59572620360423, "y": -122.50628475874987, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3833996b-287c-4a13-9e7c-6834047f3691", "name": "p1rdt7599-p1rdt8492xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5319190-a0b2-4d37-9550-a0f2b572bf96"}}}}, {"uuid": "f38d56e1-87e0-41f8-b63c-a5019038e230", "name": "", "x": 38.60515752123577, "y": -122.47345444080051, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7f6d3fab-3b83-40c9-85c4-cfeddd0d317a", "name": "p1rdt6226-p1rdt9333xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f38d56e1-87e0-41f8-b63c-a5019038e230"}}}}, {"uuid": "7d2b8e82-3663-4e48-9e89-e8e528cc8114", "name": "", "x": 38.60491485090167, "y": -122.474443511017, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "76f24b35-1b82-4760-9817-80c166073f37", "name": "p1rdt6226-p1rdt9333x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7d2b8e82-3663-4e48-9e89-e8e528cc8114"}}}}, {"uuid": "68343b22-8902-4816-b01b-158043d770b3", "name": "", "x": 38.60439463477556, "y": -122.4756262540049, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d81fc6d7-3400-41d4-91d7-b350d7def98d", "name": "p1rdt6226", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "68343b22-8902-4816-b01b-158043d770b3"}}}}, {"uuid": "4f54bf78-ef0f-44fc-9eab-cf069c5c976f", "name": "", "x": 38.572765543379965, "y": -122.49283903354065, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "36c3c493-ff68-4bb8-a3f4-043c5f847bd3", "name": "p1rdt5650-p1rdt5662x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4f54bf78-ef0f-44fc-9eab-cf069c5c976f"}}}}, {"uuid": "a982988a-244f-4f1c-aac3-e1f1824ffd2c", "name": "", "x": 38.57146366361991, "y": -122.49011602390345, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c8f1c67e-9e29-45a3-a2a3-c2f3493a6898", "name": "p1rdt5650", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a982988a-244f-4f1c-aac3-e1f1824ffd2c"}}}}, {"uuid": "1f15fd9f-5dec-450c-985a-6838f958d682", "name": "", "x": 38.566867108561745, "y": -122.49714650199947, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "81f0e00e-bc49-448a-8e69-0569ed6a8c1a", "name": "p1rdt5658-p1rdt5663x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1f15fd9f-5dec-450c-985a-6838f958d682"}}}}, {"uuid": "f75a053a-7d19-4d97-a68d-be7390bb27ae", "name": "", "x": 38.56722225496197, "y": -122.49589645931059, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e67d07fb-aec5-4120-8254-32bfcd91e378", "name": "p1rdt5658-p1rdt5663xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f75a053a-7d19-4d97-a68d-be7390bb27ae"}}}}, {"uuid": "2fa9bd24-74db-46e1-9028-ab707e76db9d", "name": "", "x": 38.56676442477756, "y": -122.497188761547, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7356d982-36fd-46cb-9300-8889502e8dc8", "name": "p1rdt5663", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2fa9bd24-74db-46e1-9028-ab707e76db9d"}}}}, {"uuid": "825e0b55-7892-413f-9b90-fe1673ed473f", "name": "", "x": 38.563115754357725, "y": -122.50436551560664, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b470fa62-70d4-4cc5-8f7e-b9cda37481e0", "name": "p1rdt7067", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "825e0b55-7892-413f-9b90-fe1673ed473f"}}}}, {"uuid": "a92aaa91-6e7b-4ef0-9c9b-44040d044206", "name": "", "x": 38.562327045687596, "y": -122.50539247201371, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9bb8596a-bcb2-4282-bf1b-9939a9af87d9", "name": "p1rdt7046", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a92aaa91-6e7b-4ef0-9c9b-44040d044206"}}}}, {"uuid": "08c625af-eec7-4383-83b2-1f963a0cd6e9", "name": "", "x": 38.56260404120564, "y": -122.50270471808909, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fb3a9847-70d0-4004-95ef-63884c6c1cdc", "name": "p1rdt7038", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "08c625af-eec7-4383-83b2-1f963a0cd6e9"}}}}, {"uuid": "aeaaaaea-e526-430b-9d4a-421fafdb5bad", "name": "", "x": 38.562387612025795, "y": -122.4991118756889, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ac6e8ccf-75ec-42e0-a3cb-9ab86e2731a4", "name": "p1rdt7070", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aeaaaaea-e526-430b-9d4a-421fafdb5bad"}}}}, {"uuid": "635cd087-1d7c-47b3-b8a7-fec348f9b62f", "name": "", "x": 38.56242616294009, "y": -122.5018066922163, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e9cb2d8d-1991-463c-9e6b-88f5624f28c3", "name": "p1rdt7038-p1rdt7070x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "635cd087-1d7c-47b3-b8a7-fec348f9b62f"}}}}, {"uuid": "bcf8098e-ebef-4e7d-a388-84e59af95fb8", "name": "", "x": 38.55588435346, "y": -122.5067067908326, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0a597011-5e60-46fe-90d6-85728ff0ffa3", "name": "p1rdt9396", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bcf8098e-ebef-4e7d-a388-84e59af95fb8"}}}}, {"uuid": "09a7dcb1-00b7-4ecb-a625-2d5c4eed9235", "name": "", "x": 38.55491482364518, "y": -122.50783397819646, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b5791345-57dc-4f54-ab54-ea63e6a54ee0", "name": "p1rdt9381", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "09a7dcb1-00b7-4ecb-a625-2d5c4eed9235"}}}}, {"uuid": "53098f16-a96d-4396-ad7d-244d0c2c5f88", "name": "", "x": 38.557265355979126, "y": -122.50588266860625, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ac70c13b-5f4f-45f3-880a-b4b476ea552a", "name": "p1rdt7088", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "53098f16-a96d-4396-ad7d-244d0c2c5f88"}}}}, {"uuid": "c3e8351c-dd1c-4e18-b0d2-d7247c861a1f", "name": "", "x": 38.55764619612384, "y": -122.50520475670933, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "31cd4834-477f-4060-8efd-0504c8e8eaa9", "name": "p1rdt7089", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c3e8351c-dd1c-4e18-b0d2-d7247c861a1f"}}}}, {"uuid": "d29fd631-620d-43b6-846e-6fbd7db41afb", "name": "", "x": 38.55961566604152, "y": -122.50276328297903, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75947ffd-3765-443b-bef8-b6af746ef624", "name": "p1rdt7061", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d29fd631-620d-43b6-846e-6fbd7db41afb"}}}}, {"uuid": "81184bc6-d55f-4e11-abb5-4dbf0edbf6ab", "name": "", "x": 38.55890205970878, "y": -122.50382809113916, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "324f5d62-9feb-4fe4-bc1b-3dcf01898148", "name": "p1rdt7061-p1rdt7089x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "81184bc6-d55f-4e11-abb5-4dbf0edbf6ab"}}}}, {"uuid": "d9a8273a-d0fb-452e-b442-66d402d6ecf2", "name": "", "x": 38.560425566891645, "y": -122.50182050287499, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "84578de8-d5de-41fe-b637-42425e97b7db", "name": "p1rdt7061-p1rdt7070x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d9a8273a-d0fb-452e-b442-66d402d6ecf2"}}}}, {"uuid": "adff7086-5c4d-4692-ab27-39fd2c9e06e3", "name": "", "x": 38.56719749877506, "y": -122.49557460649763, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "02407b52-58c3-403c-9b5b-38695f435476", "name": "p1rdt5658-p1rdt7070x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "adff7086-5c4d-4692-ab27-39fd2c9e06e3"}}}}, {"uuid": "f380a6bd-42ac-4e94-852b-71eb43d521f4", "name": "", "x": 38.58873407774302, "y": -122.47343765394794, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c0843e99-e917-473c-bec7-ee0c3ddec601", "name": "p1rdt5017-p1rdt5200x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f380a6bd-42ac-4e94-852b-71eb43d521f4"}}}}, {"uuid": "21b5d83a-8c2e-4161-94a0-5316a279921c", "name": "", "x": 38.58804691015901, "y": -122.47096337199758, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "799ab435-c0a4-4515-8125-e8ca2fb7632d", "name": "p1rdt5200", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "21b5d83a-8c2e-4161-94a0-5316a279921c"}}}}, {"uuid": "44f794c1-8e6e-4411-a416-500797f57171", "name": "", "x": 38.599124013036686, "y": -122.46398556528375, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1b28595b-dcbe-4d1b-92c4-94acf370bb1f", "name": "p1rdt7576", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "44f794c1-8e6e-4411-a416-500797f57171"}}}}, {"uuid": "59b6cf59-ca9a-4f11-a6e9-118bc61c0fc8", "name": "", "x": 38.59899175164701, "y": -122.4633858496211, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4ce65512-7d5f-4514-b55c-1775e80dd94d", "name": "p1rdt8422", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59b6cf59-ca9a-4f11-a6e9-118bc61c0fc8"}}}}, {"uuid": "036c8efd-7db2-4870-82f2-3b943df50d82", "name": "", "x": 38.59980734698757, "y": -122.46809510052073, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75a31fa2-4df8-418a-a215-d0d450ced9a3", "name": "p1rdt7576-p1rdt8151xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "036c8efd-7db2-4870-82f2-3b943df50d82"}}}}, {"uuid": "5ddda534-1bae-4376-9940-923ffa5b0268", "name": "", "x": 38.59985029320267, "y": -122.46810315325398, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "df71ab4b-258c-4812-9537-6d425bacb468", "name": "p1rdt7576-p1rdt8151xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ddda534-1bae-4376-9940-923ffa5b0268"}}}}, {"uuid": "a77eb685-3722-4073-b5e1-fe119b376547", "name": "", "x": 38.59989292024887, "y": -122.46810581013978, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c951cf67-3297-407f-805c-55d9c03fb519", "name": "p1rdt7576-p1rdt8151x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a77eb685-3722-4073-b5e1-fe119b376547"}}}}, {"uuid": "63cc9012-4b26-4a85-b7cd-a17d2b412999", "name": "", "x": 38.59895094748302, "y": -122.46820159887727, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1613a53e-5194-4d26-b83b-475d9f02a32c", "name": "p1rdt8155", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "63cc9012-4b26-4a85-b7cd-a17d2b412999"}}}}, {"uuid": "e1bf1831-29fd-4c8c-a2d8-2caca097b732", "name": "", "x": 38.59895213180579, "y": -122.4682554984801, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b706c56-20f1-49ed-9cbe-0ec1491b83e0", "name": "p1rdt8149", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e1bf1831-29fd-4c8c-a2d8-2caca097b732"}}}}, {"uuid": "67b4a3bb-1120-4c1f-a699-5860c8fa90eb", "name": "", "x": 38.5924677842981, "y": -122.4635262800833, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8b423745-cc70-4c3a-adb0-f648170b4ab1", "name": "p1rdt8441", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "67b4a3bb-1120-4c1f-a699-5860c8fa90eb"}}}}, {"uuid": "a3ed93a5-c0ba-4cc1-ae05-71fcbd30574b", "name": "", "x": 38.59106375235361, "y": -122.46454322086704, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dac2cb8c-428b-49c4-8368-35608c050390", "name": "p1rdt5153-p1rdt8441xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a3ed93a5-c0ba-4cc1-ae05-71fcbd30574b"}}}}, {"uuid": "f0f6cd73-360a-4152-8fca-73066c995f16", "name": "", "x": 38.5891703292866, "y": -122.46631406470807, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dff898c1-a386-4219-9e8d-2d08b49f9098", "name": "p1rdt5153-p1rdt8441x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f0f6cd73-360a-4152-8fca-73066c995f16"}}}}, {"uuid": "0293898d-b01c-4468-ab99-40e98ee44971", "name": "", "x": 38.58821580644588, "y": -122.46709794144316, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eb8dae66-287a-4b8a-9cda-6ae02cb8f8a9", "name": "p1rdt5153", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0293898d-b01c-4468-ab99-40e98ee44971"}}}}, {"uuid": "94f325f3-6d2a-45bc-908f-e3cea41f7886", "name": "", "x": 38.59865977452597, "y": -122.46691737157991, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "78081763-07d2-4989-b492-e1c5178c4097", "name": "p1rdt8150", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "94f325f3-6d2a-45bc-908f-e3cea41f7886"}}}}, {"uuid": "fb3cd9d4-237f-4530-bd9a-6177b42a039b", "name": "", "x": 38.59382920785335, "y": -122.46428153625678, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "83b76782-be09-4733-a35c-6f3f26059a4d", "name": "p1rdt8150-p1rdt8441x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fb3cd9d4-237f-4530-bd9a-6177b42a039b"}}}}, {"uuid": "ba950250-6005-4961-ba68-6eea3fdd90dd", "name": "", "x": 38.59741418959317, "y": -122.46389890047125, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f2ef098d-d7e6-4530-a5cc-b6472ec9ffdc", "name": "p1rdt8150-p1rdt8442x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ba950250-6005-4961-ba68-6eea3fdd90dd"}}}}, {"uuid": "2202743d-a855-497a-87e1-851058c746c5", "name": "", "x": 38.597632581049226, "y": -122.46353019233372, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f6700763-e6dc-4626-ac2b-22985f0043be", "name": "p1rdt8442", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2202743d-a855-497a-87e1-851058c746c5"}}}}, {"uuid": "105d022a-345a-4dc1-add4-903d032442f7", "name": "", "x": 38.59878207629303, "y": -122.46742572315105, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b7280d1f-5ff9-45ee-9949-ecc70509a2a1", "name": "p1rdt8150-p1rdt8155x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "105d022a-345a-4dc1-add4-903d032442f7"}}}}, {"uuid": "358f69b2-02c9-48c0-8e3a-5a7b150a456d", "name": "", "x": 38.59899028699417, "y": -122.46961983252689, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9a30e197-897f-4516-b4e5-f70081e6f8c7", "name": "p1rdt8157", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "358f69b2-02c9-48c0-8e3a-5a7b150a456d"}}}}, {"uuid": "ae0a5a8f-0550-45d5-af05-1ee69e000ba1", "name": "", "x": 38.59975154279307, "y": -122.4680237146737, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b0a6628e-afc1-4daf-8a29-7626ac2aa5dd", "name": "p1rdt8151-p1rdt8155x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ae0a5a8f-0550-45d5-af05-1ee69e000ba1"}}}}, {"uuid": "2f1aa61f-7af2-40d3-b303-0f0bc8d88847", "name": "", "x": 38.64164273016234, "y": -122.45541248693772, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f903015c-95a7-4d6e-b2a5-e9705c050c6e", "name": "p1rdt5483", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2f1aa61f-7af2-40d3-b303-0f0bc8d88847"}}}}, {"uuid": "273a046e-c5ce-4125-9e31-028bb8292c8c", "name": "", "x": 38.64024304330955, "y": -122.45644844030662, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d29d8b74-a24d-4474-9752-c1ffa1aa7f7c", "name": "p1rdt5481", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "273a046e-c5ce-4125-9e31-028bb8292c8c"}}}}, {"uuid": "68c9a036-808f-4fad-8506-4a7896b8996d", "name": "", "x": 38.641756332042426, "y": -122.45557875811565, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2568f11c-8a37-4a55-8bce-9f0d56ac386a", "name": "p1rdt5480", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "68c9a036-808f-4fad-8506-4a7896b8996d"}}}}, {"uuid": "6a9bbaf7-c083-4fc4-802d-91e2d4b0f4db", "name": "", "x": 38.642142868875986, "y": -122.45608936956037, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a7d7f462-1ab5-4fd8-baaa-7e576eead5c7", "name": "p1rdt5477", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a9bbaf7-c083-4fc4-802d-91e2d4b0f4db"}}}}, {"uuid": "33ece59e-3a10-4c95-950d-ecedcc29e1d0", "name": "", "x": 38.64281235221596, "y": -122.45532194437911, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "df1d5615-4a0b-4041-8940-f13de9f7036a", "name": "p1rdt5477-p1rdt7201x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "33ece59e-3a10-4c95-950d-ecedcc29e1d0"}}}}, {"uuid": "000a5153-68d8-45da-89ab-617a8cd6cb36", "name": "", "x": 38.64321277078752, "y": -122.4548323247065, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f64ed4a2-6afb-447c-8c6b-15935e050a6d", "name": "p1rdt7201", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "000a5153-68d8-45da-89ab-617a8cd6cb36"}}}}, {"uuid": "f7c432d6-1633-4358-86dc-895b71dd2c40", "name": "", "x": 38.642219786001824, "y": -122.45774171841002, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a8c3f7f-b9be-4c5e-b6f0-8f2fc18935fa", "name": "p1rdt5472", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f7c432d6-1633-4358-86dc-895b71dd2c40"}}}}, {"uuid": "d7d5b93b-1a5a-4f71-95e8-3f2b1a9a411b", "name": "", "x": 38.64221051314406, "y": -122.45768209005053, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "595463a5-2019-4c94-b72d-c824c2aef347", "name": "p1rdt5472-p1rdt5477x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d7d5b93b-1a5a-4f71-95e8-3f2b1a9a411b"}}}}, {"uuid": "0d4453f9-bd03-4074-82f5-92e6944000d8", "name": "", "x": 38.63937777553964, "y": -122.46168143344667, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d69527e6-70b6-43e2-8b9e-7c8570ad5ddf", "name": "p1rdt5472-p1rdt5476x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0d4453f9-bd03-4074-82f5-92e6944000d8"}}}}, {"uuid": "7c7cf273-8a35-4f1b-b0df-652e02e8d7c4", "name": "", "x": 38.634273490971374, "y": -122.45107406346328, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "02ea9067-6a2a-48b6-b5f1-10992b9fbd77", "name": "p1rdt7704", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7c7cf273-8a35-4f1b-b0df-652e02e8d7c4"}}}}, {"uuid": "7f99c451-b1c2-40d3-9f37-2911f14e0083", "name": "", "x": 38.633218038007875, "y": -122.44832866649233, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f633393e-4d67-4646-838b-14f25641b426", "name": "p1rdt7704-p1rdt9266x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7f99c451-b1c2-40d3-9f37-2911f14e0083"}}}}, {"uuid": "983285a7-75f5-4a80-b562-57390f24885f", "name": "", "x": 38.63351410324478, "y": -122.44695962318366, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6fbb2bd0-d109-4248-85f3-266fe479677f", "name": "p1rdt9266", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "983285a7-75f5-4a80-b562-57390f24885f"}}}}, {"uuid": "91a6b8b3-39c6-43fb-9476-f82b581450b9", "name": "", "x": 38.63645110302719, "y": -122.45301866057562, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4462b9c6-748f-48e9-9ff9-7f20a06cf456", "name": "p1rdt7712", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "91a6b8b3-39c6-43fb-9476-f82b581450b9"}}}}, {"uuid": "c6e2115c-5e23-404f-8d02-cfc7459bceb4", "name": "", "x": 38.63434015287993, "y": -122.45255214689988, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "048e2bab-67f2-4975-81a1-bbc9f2f9cd88", "name": "p1rdt7718", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c6e2115c-5e23-404f-8d02-cfc7459bceb4"}}}}, {"uuid": "b8a68cb6-346c-42b7-abe2-6eed14ab959d", "name": "", "x": 38.636858070821944, "y": -122.45332579295936, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "74968ebc-53c5-4fc6-8172-3ffa9dea7683", "name": "p1rdt7701", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b8a68cb6-346c-42b7-abe2-6eed14ab959d"}}}}, {"uuid": "a9d37e1d-5173-4635-a52b-7cf55ef8c650", "name": "", "x": 38.63763391930191, "y": -122.4535037389147, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ec849ee4-3d69-46a9-9a2a-242a3943e46c", "name": "p1rdt7699", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a9d37e1d-5173-4635-a52b-7cf55ef8c650"}}}}, {"uuid": "4260e8f1-7798-4deb-9e31-1fca3abf1a52", "name": "", "x": 38.63933239277819, "y": -122.45585430535672, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3cfb3a23-3a93-4d89-8b70-e4730ebbce1a", "name": "p1rdt5485", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4260e8f1-7798-4deb-9e31-1fca3abf1a52"}}}}, {"uuid": "bc656b69-36a4-43ff-b71d-c180a2f08d8e", "name": "", "x": 38.638463291461264, "y": -122.45417138292237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "890cd47a-994b-4dca-8d59-25164f04c927", "name": "p1rdt5485-p1rdt7699x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bc656b69-36a4-43ff-b71d-c180a2f08d8e"}}}}, {"uuid": "6a726f29-4815-4b7e-9cdd-3ba9cab41478", "name": "", "x": 38.639561691754864, "y": -122.45649160162748, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2b9e57e0-6dc8-4831-ac7d-36f8608b7a8d", "name": "p1rdt5475", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a726f29-4815-4b7e-9cdd-3ba9cab41478"}}}}, {"uuid": "ea984b77-b138-4d35-84e2-6f5e1b3be68a", "name": "", "x": 38.63942177536906, "y": -122.46162651516015, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ae343ca3-3337-4528-b117-38a51e6d023f", "name": "p1rdt5475-p1rdt5476x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea984b77-b138-4d35-84e2-6f5e1b3be68a"}}}}, {"uuid": "c6a41314-ff2d-43b3-b5cc-6e2a28deffa6", "name": "", "x": 38.63947133387594, "y": -122.46167250985621, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4c977e6c-43f0-4d7e-b19f-82f0de97dab2", "name": "p1rdt5476-p1rdt5478x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c6a41314-ff2d-43b3-b5cc-6e2a28deffa6"}}}}, {"uuid": "4979c1e5-b450-4e65-96a4-18e6717e9de6", "name": "", "x": 38.637232713702204, "y": -122.4583095586275, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9a97491e-2c98-4584-9b74-5593f17faeda", "name": "p1rdt5478", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4979c1e5-b450-4e65-96a4-18e6717e9de6"}}}}, {"uuid": "2eb92f32-3756-41cd-b0da-65a66c24a381", "name": "", "x": 38.629275148712736, "y": -122.45440586693407, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "96399e51-1243-4e7f-ae3a-5e2c67123aae", "name": "p1rdt6848", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2eb92f32-3756-41cd-b0da-65a66c24a381"}}}}, {"uuid": "02d00be7-cb00-4607-bd85-777ce7f0a710", "name": "", "x": 38.62915793743979, "y": -122.45307010539497, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2b764d22-debb-4d88-8221-ff79307e609f", "name": "p1rdt6848-p1rdt9264x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "02d00be7-cb00-4607-bd85-777ce7f0a710"}}}}, {"uuid": "2777bf8f-fb4b-4519-88c5-7462abde8f9a", "name": "", "x": 38.62929755153899, "y": -122.45269743640755, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6bdf3994-bb0c-44f4-b1ea-ab29e73bd39c", "name": "p1rdt9264", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2777bf8f-fb4b-4519-88c5-7462abde8f9a"}}}}, {"uuid": "d6f76c08-aa28-4f37-96e7-37ad79f4b724", "name": "", "x": 38.63204510201893, "y": -122.46437683506844, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3e92b102-eaee-41cc-a2fc-c6c4b3bfb58b", "name": "p1rdt6847", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d6f76c08-aa28-4f37-96e7-37ad79f4b724"}}}}, {"uuid": "597d61bf-b7a2-48d5-9bb2-6befc99d855a", "name": "", "x": 38.637551036439916, "y": -122.4658407872937, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be9350ab-7ad2-4a89-a374-94bf69588d7f", "name": "p1rdt6847-p1rdt7624x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "597d61bf-b7a2-48d5-9bb2-6befc99d855a"}}}}, {"uuid": "854252b7-a9be-439b-b237-47caad78812a", "name": "", "x": 38.63745413036962, "y": -122.41088901665674, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4d6c5b78-35c4-475a-8837-776dea236c95", "name": "p1rdt6348", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "854252b7-a9be-439b-b237-47caad78812a"}}}}, {"uuid": "601cbd90-802e-4147-93e4-1a0dee2ea031", "name": "", "x": 38.63621334895868, "y": -122.41023104176281, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c935f1c0-e36c-407d-a2e8-4181c4b0733e", "name": "p1rdt6350", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "601cbd90-802e-4147-93e4-1a0dee2ea031"}}}}, {"uuid": "e5e50d5c-d080-4d8d-b9cf-869a003ee1f5", "name": "", "x": 38.635943272929005, "y": -122.41464349224492, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "40280da5-767c-4610-b6a8-ff411e1c33e8", "name": "p1rdt6345", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e5e50d5c-d080-4d8d-b9cf-869a003ee1f5"}}}}, {"uuid": "2fb72ea7-b013-493a-940f-9e1e8a973dd2", "name": "", "x": 38.637135599334236, "y": -122.41985198242058, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1bdfc1ac-98a4-43dd-bb2c-837d0a2c15f9", "name": "p1rdt6356", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2fb72ea7-b013-493a-940f-9e1e8a973dd2"}}}}, {"uuid": "65123f8f-99b8-4bc5-a743-806f7f6963d0", "name": "", "x": 38.63428208141972, "y": -122.41685332058216, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8e51e0d9-24b6-40ac-859a-51ea74c93e76", "name": "p1rdt6353", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65123f8f-99b8-4bc5-a743-806f7f6963d0"}}}}, {"uuid": "ad2a38c2-3edd-4b63-9187-242b9e02e7b1", "name": "", "x": 38.637037161169054, "y": -122.41998840936154, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2040b1a2-85bc-405a-9dab-138561b5e3ac", "name": "p1rdt6354-p1rdt6356x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ad2a38c2-3edd-4b63-9187-242b9e02e7b1"}}}}, {"uuid": "3be1ed3b-9da6-42c9-8228-52e392d086e4", "name": "", "x": 38.6365030259924, "y": -122.42074352091329, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1a05e7c9-4bff-46fd-b356-8120b481b053", "name": "p1rdt6354", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3be1ed3b-9da6-42c9-8228-52e392d086e4"}}}}, {"uuid": "150904ad-1522-4a28-9697-1c2bfb036cd7", "name": "", "x": 38.63888731873398, "y": -122.42664972566449, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c7166849-6ecd-4270-bf52-d0579838336a", "name": "p1rdt6347", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "150904ad-1522-4a28-9697-1c2bfb036cd7"}}}}, {"uuid": "4d009f86-5794-4639-91c0-2a5ac3e6cdce", "name": "", "x": 38.63046949482658, "y": -122.42586839274048, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6e36f1f1-6993-46b0-bafa-9530fd1652ef", "name": "p1rdt7605", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d009f86-5794-4639-91c0-2a5ac3e6cdce"}}}}, {"uuid": "4ae5dbc6-e0bc-49e8-b304-6f7ac9362bd2", "name": "", "x": 38.63106444152601, "y": -122.42668905474402, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f95e5fa5-a84c-42a4-b519-8d344e816ecd", "name": "p1rdt7598", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ae5dbc6-e0bc-49e8-b304-6f7ac9362bd2"}}}}, {"uuid": "a5f8fa10-b048-48a1-860f-3b120eb360fa", "name": "", "x": 38.632704736208574, "y": -122.42169322012252, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5f9809eb-41e0-40a8-b43a-93556f767f68", "name": "p1rdt7589", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a5f8fa10-b048-48a1-860f-3b120eb360fa"}}}}, {"uuid": "0ce8819e-f17b-461b-8c62-5afbaabea831", "name": "", "x": 38.62803766509506, "y": -122.4206605617657, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3410d88a-3e9c-427e-a79e-5c602455ed1d", "name": "p1rdt7612", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0ce8819e-f17b-461b-8c62-5afbaabea831"}}}}, {"uuid": "5d59340d-16c5-4b89-8091-5c32f734632c", "name": "", "x": 38.64794018977543, "y": -122.44170447330542, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6163371c-55ef-4900-a3ef-2e4e8fc2894a", "name": "p1rdt6347-p1rdt8470x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5d59340d-16c5-4b89-8091-5c32f734632c"}}}}, {"uuid": "1965718d-a8b3-400b-a48b-dcee8657a6ac", "name": "", "x": 38.65468732876317, "y": -122.39725551743196, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "769c14db-ac3f-438d-9f7d-c7eb2d3074b5", "name": "p1rdt5653", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1965718d-a8b3-400b-a48b-dcee8657a6ac"}}}}, {"uuid": "29c6209f-ca61-4fb8-987f-c2da46ad0d9b", "name": "", "x": 38.65539216836069, "y": -122.39642965058673, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "98f2c16a-cdbd-49a3-b60d-4be6e9158480", "name": "p1rdt5218-p1rdt5653x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "29c6209f-ca61-4fb8-987f-c2da46ad0d9b"}}}}, {"uuid": "9ccf40bd-2c7a-40e1-a90b-72438700a78e", "name": "", "x": 38.65638553565669, "y": -122.3958356267157, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9dda7f7c-3b21-46a0-88a3-2b7f028b7772", "name": "p1rdt5218", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9ccf40bd-2c7a-40e1-a90b-72438700a78e"}}}}, {"uuid": "c08bee5c-777a-4666-8eec-9b3dd673bfbc", "name": "", "x": 38.649267204221246, "y": -122.40284351830519, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "58c6d858-d457-4fe6-a45b-b9b2b73cad8c", "name": "p1rdt5195", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c08bee5c-777a-4666-8eec-9b3dd673bfbc"}}}}, {"uuid": "f1105e91-4b0f-4530-adf0-ed1cb33735f5", "name": "", "x": 38.649760224171196, "y": -122.40177465588245, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fbc486eb-4f08-4602-a101-1298d4a46b32", "name": "p1rdt5195_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f1105e91-4b0f-4530-adf0-ed1cb33735f5"}}}}, {"uuid": "49651b45-fc27-43ca-af8d-9789a4a6004a", "name": "", "x": 38.648493079669315, "y": -122.39370880076001, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3741c9d4-d03a-4b2f-be57-52a8977351ad", "name": "p1rdt6995", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "49651b45-fc27-43ca-af8d-9789a4a6004a"}}}}, {"uuid": "4b0305c0-1037-4ef4-949a-597397ef270e", "name": "", "x": 38.648911595375175, "y": -122.39447297420028, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2d4d11a9-8de3-4dbe-8974-6005ed40f363", "name": "p1rdt6995-p1rdt7015x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4b0305c0-1037-4ef4-949a-597397ef270e"}}}}, {"uuid": "a7bc3009-8e8d-4e17-b616-c76252626a6c", "name": "", "x": 38.64914243697819, "y": -122.39455192500522, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6278a0d-f5d3-4b11-aee9-3bb23f9954a8", "name": "p1rdt7015", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a7bc3009-8e8d-4e17-b616-c76252626a6c"}}}}, {"uuid": "abb1e08a-855e-4897-a673-308816a942cc", "name": "", "x": 38.65509732869403, "y": -122.34387202316023, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6c0d417e-c787-4b0a-a39e-b19ef274b36b", "name": "p1rdt16638", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "abb1e08a-855e-4897-a673-308816a942cc"}}}}, {"uuid": "8297b428-5b23-4152-ab9c-87c2979a4b24", "name": "", "x": 38.656349996019614, "y": -122.34286866169235, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c2d0eb0b-bbb6-4b3e-bdc6-4c8a0e7d466f", "name": "p1rdt16725", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8297b428-5b23-4152-ab9c-87c2979a4b24"}}}}, {"uuid": "9a600806-0174-49eb-91db-fe69ef61fe1b", "name": "", "x": 38.65481285259022, "y": -122.34567144468134, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ddb8e50b-2619-4e74-aee6-84dc4e11389e", "name": "p1rdt16638-p1rdt6995x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9a600806-0174-49eb-91db-fe69ef61fe1b"}}}}, {"uuid": "39e782d2-a807-49ed-80d0-94565d915d21", "name": "", "x": 38.649657570740004, "y": -122.40108599864732, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9056795d-5c81-4fb9-96bc-51d63b32b187", "name": "p1rdt5195-p1rdt6995x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "39e782d2-a807-49ed-80d0-94565d915d21"}}}}, {"uuid": "cd10cffe-a98a-4acd-b67f-fc34e733b7f8", "name": "", "x": 38.647538844802774, "y": -122.40874594362695, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "227d848c-cddc-4561-996b-f8f7a60a5a89", "name": "p1rdt5195-p1rdt5202xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cd10cffe-a98a-4acd-b67f-fc34e733b7f8"}}}}, {"uuid": "089f2e83-3db8-4d79-9106-f2ded1bf5cc7", "name": "", "x": 38.64780415928914, "y": -122.40698510373619, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "43e1b69a-c6dd-447e-82d9-921998de9837", "name": "p1rdt5195-p1rdt5202xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "089f2e83-3db8-4d79-9106-f2ded1bf5cc7"}}}}, {"uuid": "26852e48-00b2-4987-9615-bb92ddc4d19d", "name": "", "x": 38.64819471408059, "y": -122.40580973948633, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8e2f2704-4dee-4c78-b199-256b907156f3", "name": "p1rdt5195-p1rdt5202x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "26852e48-00b2-4987-9615-bb92ddc4d19d"}}}}, {"uuid": "5ce2d535-677f-4124-97e4-ce80c6f3a10b", "name": "", "x": 38.64756484598567, "y": -122.4087885476493, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "97e4f179-9d60-4183-8326-eb0ab98a53eb", "name": "p1rdt5202", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ce2d535-677f-4124-97e4-ce80c6f3a10b"}}}}, {"uuid": "2e5194ca-81e3-4cce-b22d-e2f1ba68986d", "name": "", "x": 38.646212863621486, "y": -122.4077336633597, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "17fedb14-6008-43fd-b7e9-342a113f27a6", "name": "p1rdt5202-p1rdt5206x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2e5194ca-81e3-4cce-b22d-e2f1ba68986d"}}}}, {"uuid": "87956ea9-4e14-4028-a086-a242d4767471", "name": "", "x": 38.64569758673296, "y": -122.40751541256846, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2ed081eb-6b56-43b8-9cf8-e7ffdd8222f2", "name": "p1rdt5206", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "87956ea9-4e14-4028-a086-a242d4767471"}}}}, {"uuid": "f78d39fc-8180-40e0-b698-65cd5bfa44c7", "name": "", "x": 38.65086417573999, "y": -122.42606190704704, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a21680f1-33a7-44e1-9293-98c6861ba2a5", "name": "p1rdt7268", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f78d39fc-8180-40e0-b698-65cd5bfa44c7"}}}}, {"uuid": "70e977d3-80cc-4570-8493-adcde3e97600", "name": "", "x": 38.64877414711051, "y": -122.41168870941135, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6e61d2f-f75e-4335-aec9-4722942be9f1", "name": "p1rdt5202-p1rdt7268x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "70e977d3-80cc-4570-8493-adcde3e97600"}}}}, {"uuid": "72701ad2-e31a-4773-8b69-a2d3ae194283", "name": "", "x": 38.64212986886906, "y": -122.42144512012567, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "88cc1382-6b14-4500-8a21-662fce6a0c0b", "name": "p1rdt6355", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "72701ad2-e31a-4773-8b69-a2d3ae194283"}}}}, {"uuid": "c0ec56eb-72c0-4ca6-8556-375e1b1f7cc1", "name": "", "x": 38.64194634219145, "y": -122.4207801394437, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3c1edcfa-e0e4-4493-a9bb-e6033185ce67", "name": "p1rdt6349", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c0ec56eb-72c0-4ca6-8556-375e1b1f7cc1"}}}}, {"uuid": "bf893988-405e-4ab8-b905-b745f43a9a00", "name": "", "x": 38.64540330832493, "y": -122.421204010774, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eeab7dfa-540c-4275-b159-f6ac4d1350f9", "name": "p1rdt7224", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bf893988-405e-4ab8-b905-b745f43a9a00"}}}}, {"uuid": "a6dbd015-0a15-482b-9236-103a366e1112", "name": "", "x": 38.64637376282259, "y": -122.41881749796097, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b0fef9b3-a4bd-421c-8a54-cbf6f44c460d", "name": "p1rdt7618", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a6dbd015-0a15-482b-9236-103a366e1112"}}}}, {"uuid": "4c5c6dcd-63b8-41a2-8093-8cca2d72aeea", "name": "", "x": 38.649069267013274, "y": -122.42574072103456, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "22978d10-c9dc-4c84-8025-5749c730daa6", "name": "p1rdt7224-p1rdt7268x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c5c6dcd-63b8-41a2-8093-8cca2d72aeea"}}}}, {"uuid": "c46f4e0b-dc3c-4a3f-be3f-38e560bf6190", "name": "", "x": 38.64786537466463, "y": -122.44168489363972, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6225b33-2abc-4f77-9d65-459794f56353", "name": "p1rdt7268-p1rdt8470x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c46f4e0b-dc3c-4a3f-be3f-38e560bf6190"}}}}, {"uuid": "927a4063-4d22-46e6-ac4f-c015458ef7d8", "name": "", "x": 38.65324099971405, "y": -122.46490061193234, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "97198258-8ba3-4950-8747-3241c6a4fcee", "name": "p1rdt7790", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "927a4063-4d22-46e6-ac4f-c015458ef7d8"}}}}, {"uuid": "8f7b0799-74df-4334-8e29-dd46150745c8", "name": "", "x": 38.65493103663836, "y": -122.46522487253812, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "62078787-3ae2-47b3-8f67-8e89e110c8be", "name": "p1rdt7735", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8f7b0799-74df-4334-8e29-dd46150745c8"}}}}, {"uuid": "d818e1c1-0ba9-41c1-a9de-6fd225be8ae4", "name": "", "x": 38.651340821800964, "y": -122.4634244039528, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "15a7847f-aa96-4206-b4c6-422802f4e0a6", "name": "p1rdt7790-p1rdt9090x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d818e1c1-0ba9-41c1-a9de-6fd225be8ae4"}}}}, {"uuid": "fb91d7f3-340f-4966-b7e0-d358967a4734", "name": "", "x": 38.65962472553894, "y": -122.44176628998517, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "26613f51-86bf-4ae1-86c0-f23e48cf606e", "name": "p1rdt8911", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fb91d7f3-340f-4966-b7e0-d358967a4734"}}}}, {"uuid": "1bab182c-4582-47c6-8d17-29842e513a82", "name": "", "x": 38.65931212124818, "y": -122.44176119733557, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7bc7d623-3ca7-4c4e-b11c-f373e90d06b6", "name": "p1rdt8911-p1rdt9384x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1bab182c-4582-47c6-8d17-29842e513a82"}}}}, {"uuid": "b5c3aa09-2214-445c-bfa5-3d3f96eb953f", "name": "", "x": 38.65864576551388, "y": -122.44127613204223, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6eb9c7a5-5ab1-4d9b-a59e-538b68ad0bb9", "name": "p1rdt9384", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b5c3aa09-2214-445c-bfa5-3d3f96eb953f"}}}}, {"uuid": "92919a40-4844-490d-a018-5e9680adcac0", "name": "", "x": 38.660983681991716, "y": -122.44208551181131, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "924fc042-6ddc-484b-b09f-c65b35817d25", "name": "p1rdt8905", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "92919a40-4844-490d-a018-5e9680adcac0"}}}}, {"uuid": "b8032e4e-ca80-4e94-918c-c9de73f29a0c", "name": "", "x": 38.66020225533911, "y": -122.44026057728638, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "adcc33f8-72a3-434c-a021-6c5973713a91", "name": "p1rdt8916", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b8032e4e-ca80-4e94-918c-c9de73f29a0c"}}}}, {"uuid": "1df05fd9-2ce1-423d-a9c2-c03c77b85391", "name": "", "x": 38.66014117583918, "y": -122.43986982074505, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5584edfb-c31e-4e1d-87d3-b8161a59b15b", "name": "p1rdt8904-p1rdt8916x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1df05fd9-2ce1-423d-a9c2-c03c77b85391"}}}}, {"uuid": "822ecf5e-9bf8-48d7-ae80-9241a08d5eef", "name": "", "x": 38.659870600443035, "y": -122.43853470846769, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2edd17c2-6dfb-4f86-8998-b90a99755e96", "name": "p1rdt8904", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "822ecf5e-9bf8-48d7-ae80-9241a08d5eef"}}}}, {"uuid": "cfdaa503-512b-4f4b-b7d2-25964bd60174", "name": "", "x": 38.66173047874001, "y": -122.44241135887862, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "361385c6-bb6d-4bbc-ab7d-4a5774e03d82", "name": "p1rdt8915", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cfdaa503-512b-4f4b-b7d2-25964bd60174"}}}}, {"uuid": "e09dc659-3e15-4f79-91c9-b52d623601ea", "name": "", "x": 38.66056980039024, "y": -122.44983541740483, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25a9ec20-35b9-4262-a02d-cafa63e5ee42", "name": "p1rdt6574", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e09dc659-3e15-4f79-91c9-b52d623601ea"}}}}, {"uuid": "17b20f9d-2e67-45af-a1f1-f14bdf5b6629", "name": "", "x": 38.66134287929267, "y": -122.44811296163041, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c9ef9958-5d9e-4907-91cd-4c5d099daaf1", "name": "p1rdt6574-p1rdt8915x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "17b20f9d-2e67-45af-a1f1-f14bdf5b6629"}}}}, {"uuid": "c909eedd-a3ad-4f87-a346-40647f90f3ca", "name": "", "x": 38.65937095205677, "y": -122.45169503023163, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "599c6ed9-5ff7-4c97-a469-adceecaaf902", "name": "p1rdt6581", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c909eedd-a3ad-4f87-a346-40647f90f3ca"}}}}, {"uuid": "169793d1-b20d-4e43-a918-a31b39feffe4", "name": "", "x": 38.658524104486, "y": -122.45387735426675, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6114624f-81c8-4d9c-8f9a-3ab73158596e", "name": "p1rdt6581-p1rdt9084x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "169793d1-b20d-4e43-a918-a31b39feffe4"}}}}, {"uuid": "32d60b45-d56c-403d-99e5-72dbc6f6ee64", "name": "", "x": 38.65932938830671, "y": -122.45365277312096, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b2ce5116-c4f0-4ac7-a34f-3ba44c99d04b", "name": "p1rdt9076", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "32d60b45-d56c-403d-99e5-72dbc6f6ee64"}}}}, {"uuid": "ed78c300-b738-4256-82ac-69932d19430e", "name": "", "x": 38.6598966989538, "y": -122.45427706074868, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c29179f3-0b4e-449c-8562-a8fcb675be6c", "name": "p1rdt9093", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ed78c300-b738-4256-82ac-69932d19430e"}}}}, {"uuid": "67e13266-9238-4cad-9947-2673df4847a6", "name": "", "x": 38.658584295641674, "y": -122.4538145255183, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "12b4dc99-fe50-457c-90aa-48a2fb19ebf1", "name": "p1rdt9076-p1rdt9084x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "67e13266-9238-4cad-9947-2673df4847a6"}}}}, {"uuid": "783adc37-8f14-4fc0-9882-7ff2167cccc1", "name": "", "x": 38.65080476587911, "y": -122.46154361413883, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "563c6bb3-d8ed-4fce-ad66-3892426248df", "name": "p1rdt9091", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "783adc37-8f14-4fc0-9882-7ff2167cccc1"}}}}, {"uuid": "f8ebc8aa-10ca-4c4b-a76e-7b55f47da7af", "name": "", "x": 38.65078478496911, "y": -122.46111855767518, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7fcdf409-885c-4c95-834e-988842ed3f5c", "name": "p1rdt9085", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f8ebc8aa-10ca-4c4b-a76e-7b55f47da7af"}}}}, {"uuid": "20bb0b23-1255-4362-8a41-c2cb5865a639", "name": "", "x": 38.6513283597693, "y": -122.46332611842509, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf719d10-8168-4d80-894e-1b1516f033e8", "name": "p1rdt9090-p1rdt9091x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "20bb0b23-1255-4362-8a41-c2cb5865a639"}}}}, {"uuid": "9969e473-9935-40da-9183-2c6da735131b", "name": "", "x": 38.64979039983577, "y": -122.4656039969192, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a5f6a2ec-3ddd-4ba7-9c55-88b4d82e7735", "name": "p1rdt9469-p1rdt9470x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9969e473-9935-40da-9183-2c6da735131b"}}}}, {"uuid": "6263920c-9fc3-4b2e-a546-abbddd42605f", "name": "", "x": 38.65049921056124, "y": -122.46639198488886, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "acf91e46-ba32-44c3-a829-14c80a693d7d", "name": "p1rdt9470", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6263920c-9fc3-4b2e-a546-abbddd42605f"}}}}, {"uuid": "0a73ebe0-b63d-458f-a694-bef5e5e35908", "name": "", "x": 38.62473134403656, "y": -122.446341336382, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "431b672b-cb45-4294-b1f9-1d63f4efc8db", "name": "p1rdt5184", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a73ebe0-b63d-458f-a694-bef5e5e35908"}}}}, {"uuid": "40171f66-03ca-44d5-a7d9-dd81cd1d77d0", "name": "", "x": 38.62489829777773, "y": -122.44603739457851, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ceb58d66-3cb3-416d-aedf-f4949432eb37", "name": "p1rdt5140-p1rdt5184x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "40171f66-03ca-44d5-a7d9-dd81cd1d77d0"}}}}, {"uuid": "3c7c92ef-f3c4-4b07-a237-27029a3a135b", "name": "", "x": 38.625549640330384, "y": -122.44525871373254, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4b0fd055-d0ac-4678-a8e5-679e12741736", "name": "p1rdt5140", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3c7c92ef-f3c4-4b07-a237-27029a3a135b"}}}}, {"uuid": "ad9b4b7a-0931-459e-98b2-2be8e2026ce0", "name": "", "x": 38.62488841554401, "y": -122.44776290196933, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "50332aed-ecfd-465a-977e-c24ed6462860", "name": "p1rdt5154", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ad9b4b7a-0931-459e-98b2-2be8e2026ce0"}}}}, {"uuid": "8e9f56d8-7fca-4f4e-ae86-e65be9cb8c4f", "name": "", "x": 38.62229054802191, "y": -122.44975245942024, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d579047b-82f6-49bf-bd7b-28c818d44bb3", "name": "p1rdt5142", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8e9f56d8-7fca-4f4e-ae86-e65be9cb8c4f"}}}}, {"uuid": "d8684006-5b25-49fb-a434-cfc2f1c5dec1", "name": "", "x": 38.62220258438888, "y": -122.44622230651564, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c6316fa2-dd57-46d4-89c0-f11dd675d686", "name": "p1rdt5180", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d8684006-5b25-49fb-a434-cfc2f1c5dec1"}}}}, {"uuid": "0c16fccb-d717-44aa-9f38-45a6246e6956", "name": "", "x": 38.62380545487311, "y": -122.4562212466049, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b48f78d-1092-4536-bfb3-029da6a70dff", "name": "p1rdt8414", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0c16fccb-d717-44aa-9f38-45a6246e6956"}}}}, {"uuid": "1c64bcc6-45c2-4d20-8bf9-0e11de4c7265", "name": "", "x": 38.623626833691524, "y": -122.455467102224, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "50f71b3d-83ce-4526-8057-4a38042b7295", "name": "p1rdt5142-p1rdt8414x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1c64bcc6-45c2-4d20-8bf9-0e11de4c7265"}}}}, {"uuid": "0b35d36d-70fc-40d5-914c-1a06b686e5a9", "name": "", "x": 38.62564005248976, "y": -122.46602311753331, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "42929633-40d4-4e13-a0aa-a7682f328226", "name": "p1rdt6409", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0b35d36d-70fc-40d5-914c-1a06b686e5a9"}}}}, {"uuid": "319a6f16-24d3-4b77-b1e8-7f7402459352", "name": "", "x": 38.62467409594971, "y": -122.4578141983919, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c8648275-54c9-48e3-82e0-33119313924d", "name": "p1rdt6409-p1rdt8414x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "319a6f16-24d3-4b77-b1e8-7f7402459352"}}}}, {"uuid": "1e5d5efe-22c3-4d18-9fba-2f30ab355a68", "name": "", "x": 38.62028911584838, "y": -122.47934854754749, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f750e531-5ade-40a9-9bb0-042220ce9807", "name": "p1rdt9413", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1e5d5efe-22c3-4d18-9fba-2f30ab355a68"}}}}, {"uuid": "c9ef1203-c178-47da-b18f-e0dc8a149ce5", "name": "", "x": 38.607806368453346, "y": -122.45767322666612, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f9b94106-b7c5-4ce9-9c19-053487848c2a", "name": "p1rdt7570", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c9ef1203-c178-47da-b18f-e0dc8a149ce5"}}}}, {"uuid": "1ea6e363-b354-4950-a115-36df79ac7e00", "name": "", "x": 38.60650861543276, "y": -122.45746126944624, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fd487832-bc77-406f-a995-4b099fad7c64", "name": "p1rdt7574", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1ea6e363-b354-4950-a115-36df79ac7e00"}}}}, {"uuid": "a90235cd-9b37-4856-b9de-bb34434bd0c2", "name": "", "x": 38.61094163932077, "y": -122.45877502518786, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "08d4c459-5bc5-4cad-8e74-613c4a08cb35", "name": "p1rdt6275", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a90235cd-9b37-4856-b9de-bb34434bd0c2"}}}}, {"uuid": "2d935bfb-e43c-45ee-b5df-0d97d91514f4", "name": "", "x": 38.6129133935745, "y": -122.45941441983003, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3cf36152-b3af-49f7-b693-5d465db1f283", "name": "p1rdt6270", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2d935bfb-e43c-45ee-b5df-0d97d91514f4"}}}}, {"uuid": "dfb10ac3-d01d-4ffb-a16b-d27afac7c0cb", "name": "", "x": 38.61549898247823, "y": -122.4595395605965, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b5ef97a6-6c60-46eb-acce-6469b273658a", "name": "p1rdt6269", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dfb10ac3-d01d-4ffb-a16b-d27afac7c0cb"}}}}, {"uuid": "7ef54c91-36ce-43c7-8b71-0385b3d8dc94", "name": "", "x": 38.617305618456946, "y": -122.4643619588085, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60829dab-c129-4017-961a-81435d8afa93", "name": "p1rdt8405", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7ef54c91-36ce-43c7-8b71-0385b3d8dc94"}}}}, {"uuid": "f73d9123-c351-479d-ba0d-bfd88fcaeac1", "name": "", "x": 38.62031463672319, "y": -122.47930548988975, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16ecb938-cd0c-4be5-a915-be0d84d351f2", "name": "p1rdt8405-p1rdt9413x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f73d9123-c351-479d-ba0d-bfd88fcaeac1"}}}}, {"uuid": "1031a2c7-4eb4-4229-8c5a-3ba72e4b2638", "name": "", "x": 38.574957799581, "y": -122.51876395636346, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d25f8d60-8aa7-4975-96dc-eba7696fa8ae", "name": "p1rdt9314", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1031a2c7-4eb4-4229-8c5a-3ba72e4b2638"}}}}, {"uuid": "43aaaf9a-7585-41cb-8661-2358b2f561e5", "name": "", "x": 38.57551466426878, "y": -122.51886483712937, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d39c608-5688-4e22-8ac4-96b896265274", "name": "p1rdt6518", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "43aaaf9a-7585-41cb-8661-2358b2f561e5"}}}}, {"uuid": "31845f68-2f99-480e-95bc-602b2a660cb5", "name": "", "x": 38.57472269246426, "y": -122.51786257188046, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d9b006c3-79f8-4a27-b76a-d1b458ff2a21", "name": "p1rdt9479", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "31845f68-2f99-480e-95bc-602b2a660cb5"}}}}, {"uuid": "635efc5b-e76d-40a8-b026-2e8350de069e", "name": "", "x": 38.57508507780314, "y": -122.51765748560604, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9707f264-8f82-4483-8337-6c89d709faf7", "name": "p1rdt6539", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "635efc5b-e76d-40a8-b026-2e8350de069e"}}}}, {"uuid": "d5df494f-b6e9-4370-9ff0-795e3592612e", "name": "", "x": 38.575354576929136, "y": -122.51744904257968, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0db3e719-4dba-4b45-af70-c35546c19eb4", "name": "p1rdt6507", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d5df494f-b6e9-4370-9ff0-795e3592612e"}}}}, {"uuid": "6f46c81f-1ceb-4611-9652-4535d88f4fc6", "name": "", "x": 38.577519567449535, "y": -122.51578138154942, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "40ec7437-80f0-49e8-806a-c696b1402713", "name": "p1rdt6530", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6f46c81f-1ceb-4611-9652-4535d88f4fc6"}}}}, {"uuid": "33e0291b-9d5f-4928-95dc-45d472013d5d", "name": "", "x": 38.57798706705615, "y": -122.51470262020904, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b56340a0-81f0-4028-9283-532f0d92a412", "name": "p1rdt6517", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "33e0291b-9d5f-4928-95dc-45d472013d5d"}}}}, {"uuid": "f4d81409-19b9-4e42-a06c-3ce62f8ab4f9", "name": "", "x": 38.579746916502536, "y": -122.51263999956761, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "608945f2-9b19-43bc-83d9-0fe8787b06b4", "name": "p1rdt6517-p1rdt6523x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f4d81409-19b9-4e42-a06c-3ce62f8ab4f9"}}}}, {"uuid": "07f3008d-00cd-4df8-8bea-83653784bac1", "name": "", "x": 38.58000496177514, "y": -122.51234696117584, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "24028ccd-3fd3-4461-b83c-54266f91a385", "name": "p1rdt6520", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "07f3008d-00cd-4df8-8bea-83653784bac1"}}}}, {"uuid": "e3fa98f5-3d51-4345-84df-74893d453208", "name": "", "x": 38.57971971243869, "y": -122.51259440779317, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b540c710-395d-4a35-8dc3-59d37609df09", "name": "p1rdt6523", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e3fa98f5-3d51-4345-84df-74893d453208"}}}}, {"uuid": "515c2487-0a37-42d4-9ec4-2f5d75840d25", "name": "", "x": 38.58012887408336, "y": -122.51206038960157, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "99fa55d1-867c-4db0-8697-b532da10d6d4", "name": "p1rdt6501", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "515c2487-0a37-42d4-9ec4-2f5d75840d25"}}}}, {"uuid": "582e1fdd-0784-4e10-9065-38231440dc00", "name": "", "x": 38.580187053973766, "y": -122.51175395124783, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "89434ebc-1e79-4414-9925-1a14f8e72fd6", "name": "p1rdt6499", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "582e1fdd-0784-4e10-9065-38231440dc00"}}}}, {"uuid": "e50403c5-4866-4194-bb01-be0e09fa1377", "name": "", "x": 38.580244659409736, "y": -122.51143788792888, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e67c889f-e940-4242-9c83-4b5ab673d8a8", "name": "p1rdt6509", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e50403c5-4866-4194-bb01-be0e09fa1377"}}}}, {"uuid": "e659b9f0-3f1e-4b24-ab87-a5123dd51b1c", "name": "", "x": 38.58030980831637, "y": -122.51115038887805, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e165d0d-3f13-4d87-9c4b-fdfa8829f1f3", "name": "p1rdt6508", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e659b9f0-3f1e-4b24-ab87-a5123dd51b1c"}}}}, {"uuid": "b615cc6e-c30f-4996-882a-a05a0058354e", "name": "", "x": 38.580354920781474, "y": -122.5109491558155, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "302d2adf-2199-47b2-9f3c-e428bb409b6f", "name": "p1rdt6521", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b615cc6e-c30f-4996-882a-a05a0058354e"}}}}, {"uuid": "46ab54f2-6e29-4b41-b41f-06337d4964f7", "name": "", "x": 38.58042615056892, "y": -122.51074201742463, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6f7572ed-6443-4e6e-8fb8-0b060b9f17ce", "name": "p1rdt6512", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "46ab54f2-6e29-4b41-b41f-06337d4964f7"}}}}, {"uuid": "3b809375-b5a2-4775-a0b9-2676d6fda7d7", "name": "", "x": 38.58053498950995, "y": -122.5103355002012, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1ef8c502-c06f-43e5-90e6-23bd0ebcf155", "name": "p1rdt6524", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3b809375-b5a2-4775-a0b9-2676d6fda7d7"}}}}, {"uuid": "d69f12ba-021d-452d-bb69-d958c3a8cb16", "name": "", "x": 38.56382999437341, "y": -122.50863846453362, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6372a592-5e2d-41c8-819b-f56bfbb58e19", "name": "p1rdt7091", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d69f12ba-021d-452d-bb69-d958c3a8cb16"}}}}, {"uuid": "69d63238-38a7-42a0-8a20-6c9477697ccb", "name": "", "x": 38.5636996056699, "y": -122.50885698702933, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2324afa4-5274-4392-9a0e-be8dc2bebeba", "name": "p1rdt7091-p1rdt7625x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "69d63238-38a7-42a0-8a20-6c9477697ccb"}}}}, {"uuid": "37c17271-1d66-4530-babf-ba7c9bb6114e", "name": "", "x": 38.56314359789373, "y": -122.50948068684706, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3e6cbe9-d1d3-4c59-981f-dad980f0999b", "name": "p1rdt7625", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "37c17271-1d66-4530-babf-ba7c9bb6114e"}}}}, {"uuid": "dbff52e8-5b75-4845-8a22-7f8073c4f4bc", "name": "", "x": 38.56813752425825, "y": -122.50551166975698, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0cf1844f-a32e-40f2-bc96-05fad3bdd88d", "name": "p1rdt7314", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dbff52e8-5b75-4845-8a22-7f8073c4f4bc"}}}}, {"uuid": "bda52bf5-41bc-46b2-9c3d-66ebc4d33d9b", "name": "", "x": 38.56852875024663, "y": -122.50519721502558, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e86bc267-1607-4aa3-916f-ed826b0adfdc", "name": "p1rdt7318", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bda52bf5-41bc-46b2-9c3d-66ebc4d33d9b"}}}}, {"uuid": "f6353f32-6099-411d-a61a-5f3301e972e7", "name": "", "x": 38.57391341112913, "y": -122.50681689306278, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "231b5cf9-ec2c-47d1-aada-5454926561dd", "name": "p1rdt7307", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f6353f32-6099-411d-a61a-5f3301e972e7"}}}}, {"uuid": "17d081fe-5198-48d6-90b7-5bfaead55094", "name": "", "x": 38.57883713707986, "y": -122.51041811805065, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8431ef4c-78dd-4a39-b15a-95818cfe1d86", "name": "p1rdt6531-p1rdt7307x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "17d081fe-5198-48d6-90b7-5bfaead55094"}}}}, {"uuid": "1a2eb0e7-c58b-47f3-9b0b-89750d713fe9", "name": "", "x": 38.57902238646377, "y": -122.51037187678122, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "483b2d65-b496-4c6f-b01d-66aa3d9d4334", "name": "p1rdt6527", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1a2eb0e7-c58b-47f3-9b0b-89750d713fe9"}}}}, {"uuid": "353fee29-202d-4129-a38e-30d19f45d48a", "name": "", "x": 38.57879504932116, "y": -122.51042237415348, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "385eabe4-8c8e-4354-96ec-931e6c25574d", "name": "p1rdt6531", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "353fee29-202d-4129-a38e-30d19f45d48a"}}}}, {"uuid": "9feadd92-cb06-4c71-af76-75d239af08d9", "name": "", "x": 38.57912969611421, "y": -122.51047132869749, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5bd908fd-8bb8-42c1-8d1b-27c4e2574450", "name": "p1rdt6516", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9feadd92-cb06-4c71-af76-75d239af08d9"}}}}, {"uuid": "f6082925-7139-4fd8-aabe-610e992c29c1", "name": "", "x": 38.57925217424879, "y": -122.51051911433764, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6191a237-532b-44e2-86a8-d9ed56b914b5", "name": "p1rdt6516-p1rdt6524x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f6082925-7139-4fd8-aabe-610e992c29c1"}}}}, {"uuid": "fea2501d-3188-46ea-999f-cd8c413e6241", "name": "", "x": 38.580795923241645, "y": -122.50969387468216, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6a3d9ed9-e2e4-4332-89a2-358441869830", "name": "p1rdt6500-p1rdt6524x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fea2501d-3188-46ea-999f-cd8c413e6241"}}}}, {"uuid": "033688ee-3963-47a5-b30e-240a541604b3", "name": "", "x": 38.58050902502442, "y": -122.51029289847199, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "97b7ef3c-ef16-4c4d-8559-722c5c67749a", "name": "p1rdt6500-p1rdt6524xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "033688ee-3963-47a5-b30e-240a541604b3"}}}}, {"uuid": "5dac2af1-c479-42f6-95d6-e100063c675f", "name": "", "x": 38.58110574867303, "y": -122.50932633681218, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "18b822d0-cbe4-48d7-a818-87e25412d241", "name": "p1rdt6500-p1rdt6515xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5dac2af1-c479-42f6-95d6-e100063c675f"}}}}, {"uuid": "e564fdf3-ba34-4758-b781-3ed6d147914d", "name": "", "x": 38.58088888848231, "y": -122.50970513801667, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0043b26d-8a33-4e32-a963-c4638f943775", "name": "p1rdt6500-p1rdt6515x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e564fdf3-ba34-4758-b781-3ed6d147914d"}}}}, {"uuid": "e0de6dd3-0811-4bf9-a6ab-34bca44c5080", "name": "", "x": 38.58110455057315, "y": -122.5093365351204, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "04c3a970-215a-4e16-a798-80496ffad438", "name": "p1rdt6515-p1rdt6528xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e0de6dd3-0811-4bf9-a6ab-34bca44c5080"}}}}, {"uuid": "cf445906-c1c3-4e18-86a9-61dd94fab3a3", "name": "", "x": 38.58101245616958, "y": -122.50933552593602, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8dcd059f-292b-4f7a-96c1-a3dc185f1eec", "name": "p1rdt6515-p1rdt6528x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cf445906-c1c3-4e18-86a9-61dd94fab3a3"}}}}, {"uuid": "003fd690-4612-4698-bd6f-501feea117d2", "name": "", "x": 38.58147116472299, "y": -122.50902570371277, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "918984ec-3b5f-4174-9bca-771bb10e0f60", "name": "p1rdt6528-p1rdt8898xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "003fd690-4612-4698-bd6f-501feea117d2"}}}}, {"uuid": "0753826c-0c48-45ad-856a-f3ea5b33be40", "name": "", "x": 38.5810944181135, "y": -122.50923796161061, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0156ae64-03dc-4ec0-89c8-8b09a6fc9090", "name": "p1rdt6528-p1rdt8898x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0753826c-0c48-45ad-856a-f3ea5b33be40"}}}}, {"uuid": "fb1daff8-5e70-4d5f-80eb-6a7f365b58e0", "name": "", "x": 38.581587918670415, "y": -122.50894214477799, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b51e96e7-2d7f-42af-9115-c9b1cfb3131c", "name": "p1rdt6532-p1rdt8898x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fb1daff8-5e70-4d5f-80eb-6a7f365b58e0"}}}}, {"uuid": "26aa73db-5454-4f33-ba1b-b5e77e453ecf", "name": "", "x": 38.5813985191289, "y": -122.5089902200945, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "af1707bf-0b2e-4f76-96e7-c01338300d45", "name": "p1rdt6532-p1rdt8898xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "26aa73db-5454-4f33-ba1b-b5e77e453ecf"}}}}, {"uuid": "3573d3c0-5f83-4628-8077-f75cd6245d5b", "name": "", "x": 38.581811295389215, "y": -122.50861649779817, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e4a0469e-1a4a-466d-b18d-f3017b6415ae", "name": "p1rdt6532-p1rdt8902xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3573d3c0-5f83-4628-8077-f75cd6245d5b"}}}}, {"uuid": "311042de-27e1-40a3-87b6-e39cf7548d48", "name": "", "x": 38.581516114078376, "y": -122.50890397337818, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4f373554-9d8a-4a9c-b418-25e67fbb43a9", "name": "p1rdt6532-p1rdt8902x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "311042de-27e1-40a3-87b6-e39cf7548d48"}}}}, {"uuid": "c8f27702-2cc7-4484-93fd-58e51c0fb16e", "name": "", "x": 38.58365359761406, "y": -122.50734451106864, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "68b101ef-d71a-44d2-b1c2-4fc5e9f62499", "name": "p1rdt6052-p1rdt8902x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c8f27702-2cc7-4484-93fd-58e51c0fb16e"}}}}, {"uuid": "a9c3cd5e-cc7b-414b-b943-114ee1ba9f67", "name": "", "x": 38.58185095473939, "y": -122.50866687243757, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "468b1ce8-18fa-423b-99ca-1f3784437721", "name": "p1rdt6052-p1rdt8902xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a9c3cd5e-cc7b-414b-b943-114ee1ba9f67"}}}}, {"uuid": "b27f0dc4-65b4-473e-abdb-c08955bb9f83", "name": "", "x": 38.58373478464309, "y": -122.50725547084005, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "99e2ec8b-60fc-4a79-9eed-0d617babcb1d", "name": "p1rdt6046-p1rdt6052x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b27f0dc4-65b4-473e-abdb-c08955bb9f83"}}}}, {"uuid": "bc30bfc5-b613-42c4-8648-b0da774761d0", "name": "", "x": 38.583726243675486, "y": -122.5073799941088, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "49c69b43-f43b-4576-bbfa-d06b1d27de95", "name": "p1rdt6046-p1rdt6052xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bc30bfc5-b613-42c4-8648-b0da774761d0"}}}}, {"uuid": "fd4305f4-813c-4155-9c8f-cc87a063a114", "name": "", "x": 38.583771567152084, "y": -122.5072620145205, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be3d7f84-84e7-46fc-a9ce-b3e0cf74d1d3", "name": "p1rdt6043-p1rdt6046x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fd4305f4-813c-4155-9c8f-cc87a063a114"}}}}, {"uuid": "65e729c9-72ca-4616-b134-969f2edf5e19", "name": "", "x": 38.583673113710276, "y": -122.507315876951, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a147dd91-5597-40ff-93f9-0522ad3c726c", "name": "p1rdt6043-p1rdt6046xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65e729c9-72ca-4616-b134-969f2edf5e19"}}}}, {"uuid": "78471c56-df6e-47cb-97a4-ec628ff465c4", "name": "", "x": 38.583737845666946, "y": -122.50660841152015, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6f01bba4-b8e8-45ed-af3b-1ac5a287ad46", "name": "p1rdt6043-p1rdt6045xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "78471c56-df6e-47cb-97a4-ec628ff465c4"}}}}, {"uuid": "5dd9ba6c-e61b-463f-a515-95b3ddfd6abd", "name": "", "x": 38.58376143292759, "y": -122.50716343767925, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48d6768a-45e6-48a5-b22d-d5d418cb6221", "name": "p1rdt6043-p1rdt6045x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5dd9ba6c-e61b-463f-a515-95b3ddfd6abd"}}}}, {"uuid": "fcc2a891-40fa-4b5c-bdd9-244cef4e93a7", "name": "", "x": 38.584313677622774, "y": -122.50614079151774, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "34a9d21e-bcf7-4266-9834-60a72878ddd4", "name": "p1rdt6047", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fcc2a891-40fa-4b5c-bdd9-244cef4e93a7"}}}}, {"uuid": "e939a1b6-cedc-4d65-858d-686681519111", "name": "", "x": 38.58376381148312, "y": -122.50665101380328, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0396342e-2dc8-4a01-9da9-513953f9b5fa", "name": "p1rdt6045", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e939a1b6-cedc-4d65-858d-686681519111"}}}}, {"uuid": "b1e530e0-7893-4451-964c-130b7125f7f1", "name": "", "x": 38.58637708588061, "y": -122.50393363509188, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f8898950-d712-40dc-99b5-33882b96b225", "name": "p1rdt6038", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b1e530e0-7893-4451-964c-130b7125f7f1"}}}}, {"uuid": "da6f6b5b-8559-41f7-af03-efce97dc18cd", "name": "", "x": 38.59928901894631, "y": -122.48316671744382, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a086b782-3a8d-44e9-9948-cb7f051219e3", "name": "p1rdt7599", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "da6f6b5b-8559-41f7-af03-efce97dc18cd"}}}}, {"uuid": "609ac35d-fcd1-4ca4-ac26-5508b44e4ee4", "name": "", "x": 38.58770893471679, "y": -122.5028146867888, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3cfe89e9-a7a8-456d-966b-67429017f456", "name": "p1rdt6038-p1rdt7599x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "609ac35d-fcd1-4ca4-ac26-5508b44e4ee4"}}}}, {"uuid": "9b4fde9b-7944-467b-a9f5-52d268a644ee", "name": "", "x": 38.600060944468346, "y": -122.4812911472599, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0809ec5e-d36f-4bea-91b3-962ad6c29606", "name": "p1rdt6221", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9b4fde9b-7944-467b-a9f5-52d268a644ee"}}}}, {"uuid": "24852869-a1c5-4db0-95e5-c320b2bdc195", "name": "", "x": 38.60505176311642, "y": -122.47599334604853, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cdfc617f-fbfb-4e9a-862e-cd5a296748cb", "name": "p1rdt6208", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "24852869-a1c5-4db0-95e5-c320b2bdc195"}}}}, {"uuid": "d3816b74-5540-46d7-bb85-811d4c985b35", "name": "", "x": 38.60037508320662, "y": -122.48099954218519, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e1a5a109-eee6-46be-be53-3fbe4a406575", "name": "p1rdt6208-p1rdt6221x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d3816b74-5540-46d7-bb85-811d4c985b35"}}}}, {"uuid": "09ec30ea-572f-4201-ab0e-bcaa5f62e366", "name": "", "x": 38.60815051684694, "y": -122.4765469245405, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "89f0c671-9d27-4dec-bd37-dc6c56f07e5d", "name": "p1rdt6208-p1rdt8805x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "09ec30ea-572f-4201-ab0e-bcaa5f62e366"}}}}, {"uuid": "af24f76a-b2a7-4be6-998a-9c8b47186469", "name": "", "x": 38.57279151417879, "y": -122.49288162437385, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "17e89212-bc51-4fc2-83d1-4c74a285be23", "name": "p1rdt5662", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "af24f76a-b2a7-4be6-998a-9c8b47186469"}}}}, {"uuid": "9223305e-a3da-4bbd-ada6-4a46ca8d1722", "name": "", "x": 38.57272640832975, "y": -122.49539881317247, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6f2bb66-d966-4228-8a13-96c57e8fbfba", "name": "p1rdt5656-p1rdt5662x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9223305e-a3da-4bbd-ada6-4a46ca8d1722"}}}}, {"uuid": "82ef4fd2-7195-44ec-84b9-64fa3ab7a3f0", "name": "", "x": 38.57265915120934, "y": -122.49564074606137, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f417a58d-5a47-4310-bac6-e8bb95fffc19", "name": "p1rdt5656", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "82ef4fd2-7195-44ec-84b9-64fa3ab7a3f0"}}}}, {"uuid": "4a9b2caa-f848-47c9-a059-957fa52f8f06", "name": "", "x": 38.58485209359688, "y": -122.4751287858777, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "23f0bb81-3c30-45a5-89ca-2011e3881ddb", "name": "p1rdt5183", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4a9b2caa-f848-47c9-a059-957fa52f8f06"}}}}, {"uuid": "b270cdf3-cf3c-4029-a234-1c61167c5fda", "name": "", "x": 38.57451035345935, "y": -122.49113876914703, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a05b2959-a8dd-417b-b566-8f84384a3559", "name": "p1rdt5183-p1rdt5662x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b270cdf3-cf3c-4029-a234-1c61167c5fda"}}}}, {"uuid": "2a0c5a2b-f586-42b2-8ffd-fe3202072fa0", "name": "", "x": 38.58726329125732, "y": -122.47503377407112, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35487e15-57cb-4e19-bef7-49074e5eb9ee", "name": "p1rdt4980-p1rdt5183x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2a0c5a2b-f586-42b2-8ffd-fe3202072fa0"}}}}, {"uuid": "d21b0e02-57ba-4706-b64c-bf0090e0ea77", "name": "", "x": 38.588776084576374, "y": -122.47343214290899, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6c09f718-9379-4281-86f6-55c46e46aec6", "name": "p1rdt5017", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d21b0e02-57ba-4706-b64c-bf0090e0ea77"}}}}, {"uuid": "156e698e-e740-43b4-a724-4c7512ab895f", "name": "", "x": 38.58727709580159, "y": -122.47498276916237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6ddb0629-4947-47ca-83f9-9b7c073db235", "name": "p1rdt4980", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "156e698e-e740-43b4-a724-4c7512ab895f"}}}}, {"uuid": "ddb76e34-841b-49c0-b867-d88bea22d92a", "name": "", "x": 38.58932620721099, "y": -122.47402937641733, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f7f13598-e628-457c-9ba6-d9a0123e882c", "name": "p1rdt4964", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ddb76e34-841b-49c0-b867-d88bea22d92a"}}}}, {"uuid": "22773cea-500b-4798-8aa4-1df98c90efb3", "name": "", "x": 38.58925865771824, "y": -122.47388020936008, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf1c765f-ca54-48cf-806f-6a1b5719c4b0", "name": "p1rdt4964-p1rdt5017x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "22773cea-500b-4798-8aa4-1df98c90efb3"}}}}, {"uuid": "ab497915-2f5e-4f84-afff-5092914cbc85", "name": "", "x": 38.599541593142376, "y": -122.47111831101633, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "42ab6054-1866-49c5-b2ab-3cf27199c1c8", "name": "p1rdt8154", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ab497915-2f5e-4f84-afff-5092914cbc85"}}}}, {"uuid": "6f44f73f-9fc9-4ff0-b2a7-29b6a0732165", "name": "", "x": 38.59202547989681, "y": -122.47391743009182, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fb1e0d86-907d-4564-a90e-c1400917d3ca", "name": "p1rdt4964-p1rdt8154x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6f44f73f-9fc9-4ff0-b2a7-29b6a0732165"}}}}, {"uuid": "ae7ca9ea-21fa-4d1d-81bd-d01623b8672e", "name": "", "x": 38.599346582191174, "y": -122.4698450346779, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b44d5021-4fdb-4618-bcb2-237ecf2e10e4", "name": "p1rdt8153", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ae7ca9ea-21fa-4d1d-81bd-d01623b8672e"}}}}, {"uuid": "da4c3120-9386-4ac0-a965-1d368dc4eb77", "name": "", "x": 38.59932444954078, "y": -122.4697759036714, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "40962258-28d3-4406-9e9e-121f373cce25", "name": "p1rdt8151-p1rdt8153x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "da4c3120-9386-4ac0-a965-1d368dc4eb77"}}}}, {"uuid": "a605e89a-2a49-4fb3-a6a6-235d6b52275e", "name": "", "x": 38.599762625990174, "y": -122.46808190408947, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6c794942-d5ce-481f-9c6a-563a2180a4ba", "name": "p1rdt8151", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a605e89a-2a49-4fb3-a6a6-235d6b52275e"}}}}, {"uuid": "cb85fe25-d34d-4660-90eb-26a04f0f26af", "name": "", "x": 38.605132002398605, "y": -122.47349749138557, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0da91bf8-b687-47df-a7dc-41e6166fd667", "name": "p1rdt9333", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb85fe25-d34d-4660-90eb-26a04f0f26af"}}}}, {"uuid": "5bf299c2-dd95-465a-bd1c-6550b9c7ecd1", "name": "", "x": 38.60218088899386, "y": -122.47169573381588, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0aef77ef-aaaa-4a6e-90ef-87348baaf1a0", "name": "p1rdt8154-p1rdt9333x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5bf299c2-dd95-465a-bd1c-6550b9c7ecd1"}}}}, {"uuid": "7ed57c9a-f3a4-432d-931f-5fcbd8226827", "name": "", "x": 38.608136170076634, "y": -122.47649614861295, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3444af6b-f9d4-4229-b6b2-2114300c3f94", "name": "p1rdt8805", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7ed57c9a-f3a4-432d-931f-5fcbd8226827"}}}}, {"uuid": "9361e3c5-5508-49d1-8324-50197f15d00b", "name": "", "x": 38.609815768546184, "y": -122.4765312522036, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "26ccaeff-3a34-4835-8906-1145148549c6", "name": "p1rdt8802", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9361e3c5-5508-49d1-8324-50197f15d00b"}}}}, {"uuid": "f2365584-be6c-4540-994c-e874243d629f", "name": "", "x": 38.609928396533334, "y": -122.47651694646427, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "401576cc-4ad6-42cd-bf1c-4022da720711", "name": "p1rdt8802-p1rdt9413xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f2365584-be6c-4540-994c-e874243d629f"}}}}, {"uuid": "f510224a-87d0-4a9f-8bfe-1825b789e2b8", "name": "", "x": 38.618837809141326, "y": -122.47838533286804, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e527bf48-b574-43bd-9a5d-484654dc76fe", "name": "p1rdt8802-p1rdt9413x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f510224a-87d0-4a9f-8bfe-1825b789e2b8"}}}}, {"uuid": "f194c891-16c9-4a51-b620-232d3a58f3c7", "name": "", "x": 38.62912673381444, "y": -122.48799793138168, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c0dafde2-c08e-4624-9212-e0fea9e47c2c", "name": "p1rdt5126", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f194c891-16c9-4a51-b620-232d3a58f3c7"}}}}, {"uuid": "93aa763a-d394-4fea-a89b-8ff3e9f2f138", "name": "", "x": 38.64192278671691, "y": -122.50364415036834, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4c8f9ea6-06fb-4fd0-8629-ceea4f32189f", "name": "p1rdt5342", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "93aa763a-d394-4fea-a89b-8ff3e9f2f138"}}}}, {"uuid": "e897b484-4f5d-4511-96ed-69f112c49f0c", "name": "", "x": 38.63755626056743, "y": -122.46589422645306, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7e240270-762d-49f0-a4e4-29fcd6273ce5", "name": "p1rdt7624", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e897b484-4f5d-4511-96ed-69f112c49f0c"}}}}, {"uuid": "0d2d5b6d-abe4-4eb9-ab07-26bdb36af719", "name": "", "x": 38.63942506778048, "y": -122.46168548768624, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b077dc9c-1c6f-4403-ae0c-954e7cc0c692", "name": "p1rdt5476", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0d2d5b6d-abe4-4eb9-ab07-26bdb36af719"}}}}, {"uuid": "148a4099-82af-42f4-b914-66cf29ec0d00", "name": "", "x": 38.643194242872035, "y": -122.47115740856567, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "42b9c576-ddba-4be1-bc64-a37d8cbdfa84", "name": "p1rdt8159", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "148a4099-82af-42f4-b914-66cf29ec0d00"}}}}, {"uuid": "91243721-ce14-4cc8-a69c-acbee3ff9fda", "name": "", "x": 38.64188879325188, "y": -122.47007141909909, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d1ab9716-b9f3-44e5-b9f6-cd83d0904dd3", "name": "p1rdt7624-p1rdt8159x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "91243721-ce14-4cc8-a69c-acbee3ff9fda"}}}}, {"uuid": "cff42dc3-ba94-4c55-a541-87283cc47044", "name": "", "x": 38.64458771393313, "y": -122.47217469285334, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25946c74-15c2-412c-baed-8de5f7aecf98", "name": "p1rdt8161", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cff42dc3-ba94-4c55-a541-87283cc47044"}}}}, {"uuid": "ced643af-8d28-41e7-81bc-9298c8c8a7c1", "name": "", "x": 38.64808407134208, "y": -122.45916844730037, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f31b09da-e4cc-409e-9634-1907480039ff", "name": "p1rdt7253", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ced643af-8d28-41e7-81bc-9298c8c8a7c1"}}}}, {"uuid": "9f7fd998-363e-47bc-a5ec-6acba95517ae", "name": "", "x": 38.64789780072754, "y": -122.44172571021984, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "442de065-9e2a-4ff8-9100-1298d3fe0f6f", "name": "p1rdt8470", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9f7fd998-363e-47bc-a5ec-6acba95517ae"}}}}, {"uuid": "33742eaa-2507-43f4-8e91-c5c625e02232", "name": "", "x": 38.648387196658014, "y": -122.46102160071564, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7a006c5f-e960-4ae2-a37f-d23d7b873a22", "name": "p1rdt7248", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "33742eaa-2507-43f4-8e91-c5c625e02232"}}}}, {"uuid": "7104919f-4adc-4a80-8457-659bf8f006bc", "name": "", "x": 38.64846046981178, "y": -122.46458969235934, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a2f1a631-48f7-4291-9adb-588a66620ebf", "name": "p1rdt7220", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7104919f-4adc-4a80-8457-659bf8f006bc"}}}}, {"uuid": "60ab8c09-8396-4f17-b6fd-aa407a787161", "name": "", "x": 38.64777195633766, "y": -122.46661554016796, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "38b72c12-2e2f-4d83-8f5a-9d8503dc29eb", "name": "p1rdt8160", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "60ab8c09-8396-4f17-b6fd-aa407a787161"}}}}, {"uuid": "11246cdc-f535-43ac-bc2f-283ef1067f9a", "name": "", "x": 38.655229305360514, "y": -122.45615922843626, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "907828f5-8e26-41c4-8fbc-a3744608181a", "name": "p1rdt9075", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "11246cdc-f535-43ac-bc2f-283ef1067f9a"}}}}, {"uuid": "e870ef83-64a3-438a-8029-6d8886b57301", "name": "", "x": 38.65752720541336, "y": -122.45501513442589, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c10b6848-6c57-4243-8cb9-ec28d0a4c9dd", "name": "p1rdt9075-p1rdt9084x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e870ef83-64a3-438a-8029-6d8886b57301"}}}}, {"uuid": "815040ca-6a4c-4405-8579-ff7a3f914bfc", "name": "", "x": 38.65853988991046, "y": -122.45382366130036, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4251587d-600f-40a0-9aec-229fb2e3f2df", "name": "p1rdt9084", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "815040ca-6a4c-4405-8579-ff7a3f914bfc"}}}}, {"uuid": "cd1cc0f4-b4ac-4522-bdd8-e3dc70594d6a", "name": "", "x": 38.652201124748096, "y": -122.4614412233577, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0b7f2f09-976a-45da-8186-229aeedeb689", "name": "p1rdt9077", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cd1cc0f4-b4ac-4522-bdd8-e3dc70594d6a"}}}}, {"uuid": "9d8b7eaa-852a-4c6d-b0c9-1b2426b9217a", "name": "", "x": 38.65243762839318, "y": -122.46214490936109, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1b4ec275-bea8-45f2-94cb-5e24e82179d8", "name": "p1rdt9089", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9d8b7eaa-852a-4c6d-b0c9-1b2426b9217a"}}}}, {"uuid": "0616daa6-3191-4406-9a69-d24e5f3a9dd4", "name": "", "x": 38.65135661168091, "y": -122.46337071841116, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "52c72b52-1c6c-46f6-adbe-1054eb233c20", "name": "p1rdt9090", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0616daa6-3191-4406-9a69-d24e5f3a9dd4"}}}}, {"uuid": "e4ace3e4-f86a-4403-840c-5233a8d47f89", "name": "", "x": 38.65237921170061, "y": -122.46231727928001, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e4d2db3-67c5-4fef-996a-5774803c89b1", "name": "p1rdt9089-p1rdt9090x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e4ace3e4-f86a-4403-840c-5233a8d47f89"}}}}, {"uuid": "f6b9afad-4208-4121-9829-dc64e012f791", "name": "", "x": 38.649831613431125, "y": -122.46561633896845, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3fd32c7-2866-4699-93a8-dd3a9997d349", "name": "p1rdt9469", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f6b9afad-4208-4121-9829-dc64e012f791"}}}}, {"uuid": "b4d949aa-8e70-4f2e-b001-812a6d42b686", "name": "", "x": 38.65039847441097, "y": -122.46468794326384, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "708803a5-3daf-4892-96e3-b182e2d214ec", "name": "p1rdt9090-p1rdt9469x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b4d949aa-8e70-4f2e-b001-812a6d42b686"}}}}, {"uuid": "ba7b18f7-6460-41e0-9b2b-3f9af5c9c69c", "name": "", "x": 38.64456173566906, "y": -122.4721320674015, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c8ecbd5b-6db5-44a0-b2a8-0233d4eb5b20", "name": "p1rdt8160-p1rdt8161xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ba7b18f7-6460-41e0-9b2b-3f9af5c9c69c"}}}}, {"uuid": "331f72b2-c8fa-4979-a0f4-6b7c8286c289", "name": "", "x": 38.645703216313166, "y": -122.47060639662344, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cc9cbaf2-05bd-49aa-bd14-a363d4970d0f", "name": "p1rdt8160-p1rdt8161x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "331f72b2-c8fa-4979-a0f4-6b7c8286c289"}}}}, {"uuid": "d7c8d0dd-b7e9-4606-b2ed-56da52b32e46", "name": "", "x": 38.641446776145905, "y": -122.48088775120242, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "22db53ea-6d9a-4527-9b36-34a4bcd2c74f", "name": "p1rdt5236", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d7c8d0dd-b7e9-4606-b2ed-56da52b32e46"}}}}, {"uuid": "f3e02c92-fbc6-412b-8ea3-c179fa8c1404", "name": "", "x": 38.64423596256915, "y": -122.47297284989183, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "67967bdd-155c-49fd-8d4c-29b40415a243", "name": "p1rdt5236-p1rdt8161x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f3e02c92-fbc6-412b-8ea3-c179fa8c1404"}}}}, {"uuid": "4ae6ae6c-48be-4637-a5e1-b25dc9fa53b0", "name": "", "x": 38.64189681984152, "y": -122.50360151499711, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9bbfae79-a578-4ff2-b622-3dddd9859ac8", "name": "p1rdt5236-p1rdt5342x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ae6ae6c-48be-4637-a5e1-b25dc9fa53b0"}}}}, {"uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac", "name": "", "limit_type": "min", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "base"}}, "value": {"value": 0.26327172275046934, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}}, {"uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b", "name": "", "limit_type": "max", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "base"}}, "value": {"value": 0.2909845356715714, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}}, {"uuid": "c506c458-594e-4c5f-9e1f-7e22db8220b6", "name": "", "x": 38.62487405627925, "y": -122.44771212016306, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9750085f-4afd-48ee-89f3-edbe9687b242", "name": "p1rdt5154lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c506c458-594e-4c5f-9e1f-7e22db8220b6"}}}}, {"uuid": "090a2c8f-a953-4cac-b416-8e61fbf2d4b4", "name": "", "x": 38.62484806916583, "y": -122.44766951523545, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "08331744-08b7-455e-b2ca-284cae95fb06", "name": "p1rlv10539", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "090a2c8f-a953-4cac-b416-8e61fbf2d4b4"}}}}, {"uuid": "80a16f1a-9fbf-462f-b254-04a16da0b948", "name": "", "x": 38.62592881156844, "y": -122.44183363220685, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7235cf3a-dd26-47f7-884c-6335024a3064", "name": "p1rdt7632lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "80a16f1a-9fbf-462f-b254-04a16da0b948"}}}}, {"uuid": "18196f08-5ffc-4531-9ce1-984f0bd06c0b", "name": "", "x": 38.62591502181451, "y": -122.4418846707521, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "606bf8f6-d745-4220-8cae-e01ffd22f669", "name": "p1rlv16271", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "18196f08-5ffc-4531-9ce1-984f0bd06c0b"}}}}, {"uuid": "4739b7b5-d6d6-4a0f-bdca-ee44962ae707", "name": "", "x": 38.6268422350558, "y": -122.44358917844923, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b336e76f-17f3-4f5d-ba84-f24c3a4e3eed", "name": "p1rdt9265", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4739b7b5-d6d6-4a0f-bdca-ee44962ae707"}}}}, {"uuid": "9eb2fe35-b2d7-4c73-bc6a-9b8f07206031", "name": "", "x": 38.62595431848947, "y": -122.4417905580223, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "36e7cd28-6795-41d5-847d-92347871384f", "name": "p1rdt7632", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9eb2fe35-b2d7-4c73-bc6a-9b8f07206031"}}}}, {"uuid": "525621bc-eb00-4748-9592-9b3796d898ad", "name": "", "x": 38.626761518561686, "y": -122.44366797538842, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60837f06-40cb-4f12-b36f-fe5e502c96d9", "name": "p1rdt5140-p1rdt9265x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "525621bc-eb00-4748-9592-9b3796d898ad"}}}}, {"uuid": "0510f432-bc9d-4b48-a131-cc95b95f987b", "name": "", "x": 38.61321159266958, "y": -122.45774317693665, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a6614f5e-517f-46cf-b049-09337d57228a", "name": "p1rdt6279lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0510f432-bc9d-4b48-a131-cc95b95f987b"}}}}, {"uuid": "ffeb8cee-60ff-44ce-9b89-c90087251208", "name": "", "x": 38.613584450478484, "y": -122.45866725103048, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d46fd47-37f5-48a0-ba0d-d0746e6e6da3", "name": "p1rlv13061", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ffeb8cee-60ff-44ce-9b89-c90087251208"}}}}, {"uuid": "a7225ef2-cbbe-49a3-8b48-2c2e91ae95c5", "name": "", "x": 38.6133095747888, "y": -122.45770086863982, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cb21415c-fc85-4197-82e5-545cb7be2ce9", "name": "p1rdt6270-p1rdt6279x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a7225ef2-cbbe-49a3-8b48-2c2e91ae95c5"}}}}, {"uuid": "099a9c55-b1e0-4be0-af0f-adc080f914d6", "name": "", "x": 38.612910443068216, "y": -122.45907432656523, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e1565cfb-f699-47db-9cbf-a76c32e3ea69", "name": "p1rdt6270-p1rdt6279xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "099a9c55-b1e0-4be0-af0f-adc080f914d6"}}}}, {"uuid": "0c2c958b-2765-4873-9426-4fa8b298bc4c", "name": "", "x": 38.61301688005345, "y": -122.45941707430568, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5c579309-9c05-4bae-ab97-2eca485e5ea7", "name": "p1rdt6270-p1rdt6279xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0c2c958b-2765-4873-9426-4fa8b298bc4c"}}}}, {"uuid": "be1c5948-74ad-4790-a797-5c9bd7d6e7f9", "name": "", "x": 38.61683166262397, "y": -122.45474510217191, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "07992f45-0c92-4a10-837d-4f58599d9b75", "name": "p1rdt6273lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be1c5948-74ad-4790-a797-5c9bd7d6e7f9"}}}}, {"uuid": "6be47282-79b1-4511-94e5-ba580ff9b1bf", "name": "", "x": 38.61682643350382, "y": -122.4546916792451, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "051eba03-4728-4626-8add-5410b5326dc7", "name": "p1rlv13050", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6be47282-79b1-4511-94e5-ba580ff9b1bf"}}}}, {"uuid": "b647496e-436e-4fc4-84b3-eded4e8a1dbb", "name": "", "x": 38.6162564916241, "y": -122.45492283366434, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b2f8b91d-339f-4151-90df-b0cad5c2f05a", "name": "p1rdt6268", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b647496e-436e-4fc4-84b3-eded4e8a1dbb"}}}}, {"uuid": "db758a6a-9d1d-4ea1-816d-048640f12fc9", "name": "", "x": 38.61683285323747, "y": -122.45479901485551, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4d04f281-f394-432b-8b5c-cc1acb741369", "name": "p1rdt6273", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "db758a6a-9d1d-4ea1-816d-048640f12fc9"}}}}, {"uuid": "57780dd4-af7d-49dd-9de4-ad650c6a06a4", "name": "", "x": 38.61589336043255, "y": -122.45601994462623, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b31c2adb-e4f4-4211-aac7-f317bf325d12", "name": "p1rdt6268-p1rdt6276xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "57780dd4-af7d-49dd-9de4-ad650c6a06a4"}}}}, {"uuid": "d29d0187-de06-4d15-97ce-b21f4a1f04fa", "name": "", "x": 38.61634551176407, "y": -122.45552215649514, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ce404489-b775-486b-9379-a30c801f6f94", "name": "p1rdt6268-p1rdt6276xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d29d0187-de06-4d15-97ce-b21f4a1f04fa"}}}}, {"uuid": "8012248e-cccf-438a-8364-34bcc51f62c8", "name": "", "x": 38.61623050711647, "y": -122.4548802311643, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "68d2e030-852f-44f6-9e02-d5587a1fc6a0", "name": "p1rdt6268-p1rdt6276x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8012248e-cccf-438a-8364-34bcc51f62c8"}}}}, {"uuid": "a176b6e8-4da7-46f4-9ac6-cced26eb5e19", "name": "", "x": 38.616457957404585, "y": -122.4575517341824, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "51eefb94-724e-4dfe-9823-0f6cf8f56101", "name": "p1rdt6278", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a176b6e8-4da7-46f4-9ac6-cced26eb5e19"}}}}, {"uuid": "cc466d34-d930-4734-9094-61f34464eca8", "name": "", "x": 38.61591934452827, "y": -122.45606254734442, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "315af04d-a032-43a8-a2da-b9e68fd21f39", "name": "p1rdt6276", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc466d34-d930-4734-9094-61f34464eca8"}}}}, {"uuid": "1f9d8fc5-698a-40b8-adc4-7b10d6df6183", "name": "", "x": 38.616039041002885, "y": -122.45805901946764, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1dd4f893-7921-41c3-9e9e-d33e3680a999", "name": "p1rdt6277", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1f9d8fc5-698a-40b8-adc4-7b10d6df6183"}}}}, {"uuid": "d1d13ad6-e94b-45fe-8357-d6f81f83b860", "name": "", "x": 38.61556885068546, "y": -122.45905436217652, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "699595d6-8e08-41b1-8c3a-2aef170bb5f7", "name": "p1rdt6269-p1rdt6277x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1d13ad6-e94b-45fe-8357-d6f81f83b860"}}}}, {"uuid": "36918a38-3551-4a37-9465-3fda5261e1f9", "name": "", "x": 38.58377814515449, "y": -122.50670177876174, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "70bad714-71c1-4341-ac40-76312417dd03", "name": "p1rdt6045lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "36918a38-3551-4a37-9465-3fda5261e1f9"}}}}, {"uuid": "9e1584f4-9724-4c9e-ac13-d6b255344a7e", "name": "", "x": 38.58357344171333, "y": -122.50663601797484, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cc71e486-4a44-466d-bc57-85591b269949", "name": "p1rlv12555", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9e1584f4-9724-4c9e-ac13-d6b255344a7e"}}}}, {"uuid": "451fea3b-acbb-4e8f-9fea-77a4fda7de34", "name": "", "x": 38.58366602224418, "y": -122.50744271243232, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9d830a1b-6971-4f4d-99bd-945e0785b5aa", "name": "p1rdt6052lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "451fea3b-acbb-4e8f-9fea-77a4fda7de34"}}}}, {"uuid": "659f553d-9923-4b22-86f3-a0526d8303ff", "name": "", "x": 38.583654744101715, "y": -122.507354817808, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "29476f95-f85b-4843-a847-3d9d99da3b74", "name": "p1rlv12567", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "659f553d-9923-4b22-86f3-a0526d8303ff"}}}}, {"uuid": "95152bb2-254c-4961-8510-d3ef791e29bc", "name": "", "x": 38.58176166095416, "y": -122.50864860767257, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d1c8eb9-7f79-49ad-9e93-6c7cdcc95e22", "name": "p1rdt8902lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "95152bb2-254c-4961-8510-d3ef791e29bc"}}}}, {"uuid": "81cdea77-c892-4abd-93bc-946ff7be1759", "name": "", "x": 38.58164914879979, "y": -122.50832144611942, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a02024b5-aa74-4e07-b043-a7a0e8b3e816", "name": "p1rlv19164", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "81cdea77-c892-4abd-93bc-946ff7be1759"}}}}, {"uuid": "309b639b-14c0-47a6-8c13-ad4e20b47956", "name": "", "x": 38.57552859055316, "y": -122.51515559102107, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c3f191ff-f8f2-4f13-af83-e67d1fdd366a", "name": "p1rdt6537lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "309b639b-14c0-47a6-8c13-ad4e20b47956"}}}}, {"uuid": "5cf221cf-25ef-476c-af52-9402540f80d9", "name": "", "x": 38.575486581492186, "y": -122.51516107668057, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fe1a5da7-bdac-46a6-ab32-addc4f02a296", "name": "p1rlv13720", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5cf221cf-25ef-476c-af52-9402540f80d9"}}}}, {"uuid": "b8957f06-0823-465f-8389-1f4b1f7e4316", "name": "", "x": 38.575576829321776, "y": -122.51521644999882, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "45aca6e5-a8ee-4f45-80f3-e227379d33af", "name": "p1rdt6530-p1rdt6537x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b8957f06-0823-465f-8389-1f4b1f7e4316"}}}}, {"uuid": "af35ac47-262a-4419-82ab-afddde769dc1", "name": "", "x": 38.57557088455815, "y": -122.51515412712796, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "902291fa-9561-4f40-a4b7-4fd9fdded417", "name": "p1rdt6537", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "af35ac47-262a-4419-82ab-afddde769dc1"}}}}, {"uuid": "7cdaa1b9-0c0d-4944-9718-3cdadc5f131b", "name": "", "x": 38.56672395074998, "y": -122.5002666540795, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "41e61263-feb6-4264-965a-fd1309d997a1", "name": "p1rdt7313lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7cdaa1b9-0c0d-4944-9718-3cdadc5f131b"}}}}, {"uuid": "a5a69c8d-398f-44f6-a78a-cb55e8a7fb4d", "name": "", "x": 38.566682740186856, "y": -122.50025430587122, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "13eabcb1-332a-4c7a-8042-214ada721424", "name": "p1rlv15628", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a5a69c8d-398f-44f6-a78a-cb55e8a7fb4d"}}}}, {"uuid": "6dab9a69-1039-4816-bab2-3d238cf7bc4b", "name": "", "x": 38.566766241557346, "y": -122.50026502368816, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1a3a5e1c-77a2-4a9d-89e0-7d1c94176787", "name": "p1rdt7313", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6dab9a69-1039-4816-bab2-3d238cf7bc4b"}}}}, {"uuid": "44f035bc-740e-4f8c-86ee-3b2ed3b46052", "name": "", "x": 38.563855959465826, "y": -122.50868105587648, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f0c42b48-7ca4-465f-b17c-048cb5f6d79b", "name": "p1rdt7091lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "44f035bc-740e-4f8c-86ee-3b2ed3b46052"}}}}, {"uuid": "912aee73-148f-4e1f-af3c-8095f22549b6", "name": "", "x": 38.56387029221525, "y": -122.50873180728178, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "64634ab5-a5b0-45ae-9763-7d0be029350f", "name": "p1rlv15196", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "912aee73-148f-4e1f-af3c-8095f22549b6"}}}}, {"uuid": "3e40222f-8bb5-4b72-b0a8-3c1677f45386", "name": "", "x": 38.56720551439007, "y": -122.4954680905678, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f718935b-704d-4374-9172-856511e1eddd", "name": "p1rdt5658lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e40222f-8bb5-4b72-b0a8-3c1677f45386"}}}}, {"uuid": "e55dae49-706c-4edc-b323-1c5994e7842a", "name": "", "x": 38.56720030404839, "y": -122.4954147012043, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4747e0f3-2a66-4e5a-8160-ac0aabe34489", "name": "p1rlv11679", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e55dae49-706c-4edc-b323-1c5994e7842a"}}}}, {"uuid": "a496582f-3ab4-48b4-8bbe-9d948841118a", "name": "", "x": 38.56720668600247, "y": -122.49552196704039, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "81d6db26-881f-4cae-9514-df4c1e71c76e", "name": "p1rdt5658", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a496582f-3ab4-48b4-8bbe-9d948841118a"}}}}, {"uuid": "1e229978-bde6-49d6-88ef-a59ac7598fc7", "name": "", "x": 38.65216422809464, "y": -122.48679328426424, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0bab7e6b-74a6-4fe4-95e1-4ef96084f730", "name": "p1rdt5236-p1rdt8138x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1e229978-bde6-49d6-88ef-a59ac7598fc7"}}}}, {"uuid": "8e8eb4b7-82cc-4705-8d79-553180a38da3", "name": "", "x": 38.61289959602905, "y": -122.4594654458467, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "658514b3-59fd-44b7-95d6-a34cafcb47c5", "name": "p1rdt6270-p1rdt6271x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8e8eb4b7-82cc-4705-8d79-553180a38da3"}}}}, {"uuid": "cef73316-4e05-44ba-b446-d7d3a9c4fde4", "name": "", "x": 38.58084780242867, "y": -122.5096251869554, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c9938a5c-b1cd-4592-814d-324ff2eb6644", "name": "p1rdt6500-p1rdt6519x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cef73316-4e05-44ba-b446-d7d3a9c4fde4"}}}}, {"uuid": "10ccc3bc-3003-4ac7-b98e-a169941c9b43", "name": "", "x": 38.58086518694643, "y": -122.50946246615781, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "addd9f38-279f-4d9e-b216-38faef1940c7", "name": "p1rdt6519", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10ccc3bc-3003-4ac7-b98e-a169941c9b43"}}}}, {"uuid": "95e0e7cd-6529-4d7c-a009-4b5b33ed93ec", "name": "", "x": 38.58105786983961, "y": -122.50938072179505, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "acd6da90-895c-4d2c-80b4-1712b3949993", "name": "p1rdt6515-p1rdt6535x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "95e0e7cd-6529-4d7c-a009-4b5b33ed93ec"}}}}, {"uuid": "18ac8c15-27a3-4d77-af88-1d8055d5385e", "name": "", "x": 38.581060631396625, "y": -122.50954681794376, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b13053e-033e-4fe9-8eb3-89389e4bdc2b", "name": "p1rdt6535", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "18ac8c15-27a3-4d77-af88-1d8055d5385e"}}}}, {"uuid": "a4a67019-41da-4511-8cc7-c84f86f0e2b8", "name": "", "x": 38.58103206808594, "y": -122.50926637153142, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e0103161-4b16-4d25-a1f3-5a939317461f", "name": "p1rdt6515-p1rdt6536x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a4a67019-41da-4511-8cc7-c84f86f0e2b8"}}}}, {"uuid": "ba0629ba-5833-457a-b255-6ff9469bcdcf", "name": "", "x": 38.58096111560494, "y": -122.50912674534362, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8f5cda74-5e33-4c52-8b2c-76bcd5e6c5cb", "name": "p1rdt6536", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ba0629ba-5833-457a-b255-6ff9469bcdcf"}}}}, {"uuid": "ece0a614-8728-4152-bad4-c2f58d2cff06", "name": "", "x": 38.580843572870805, "y": -122.50968387919501, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "78b3b940-c277-441f-b2b3-83525ed85fcb", "name": "p1rdt6500", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ece0a614-8728-4152-bad4-c2f58d2cff06"}}}}, {"uuid": "a6631bf9-7546-47a7-b00b-9c15f3d90c15", "name": "", "x": 38.58105789188953, "y": -122.50931876846892, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f1537ab1-dc7c-4bbd-b347-fc740d54fcf7", "name": "p1rdt6515", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a6631bf9-7546-47a7-b00b-9c15f3d90c15"}}}}, {"uuid": "af42ea4f-a084-4c6c-9c59-95018e4fa65f", "name": "", "x": 38.58107734523138, "y": -122.50929094375307, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6ef5115d-ad7b-4671-b984-b9fd5969bf61", "name": "p1rdt6528", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "af42ea4f-a084-4c6c-9c59-95018e4fa65f"}}}}, {"uuid": "a3ccc5ea-84ec-45d4-9bc1-bd1015516736", "name": "", "x": 38.581426753801445, "y": -122.50903479519879, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9d887dbc-43bd-413e-8e72-5c95a2ed0be8", "name": "p1rdt8898", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a3ccc5ea-84ec-45d4-9bc1-bd1015516736"}}}}, {"uuid": "876c20e0-46d2-4171-bdcd-67bcae4f8a23", "name": "", "x": 38.581560713176216, "y": -122.50889655325749, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d9f12ed7-454c-4cc9-a631-377121a07ba5", "name": "p1rdt6532", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "876c20e0-46d2-4171-bdcd-67bcae4f8a23"}}}}, {"uuid": "549b0bcc-dd32-407b-a3ba-c7ee12c8c856", "name": "", "x": 38.5818039862915, "y": -122.50867642493746, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4f44ec9b-338a-4ae1-a26b-26422f218c13", "name": "p1rdt8902", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "549b0bcc-dd32-407b-a3ba-c7ee12c8c856"}}}}, {"uuid": "8ac7b79d-e22a-43be-ae62-480551b5dfe1", "name": "", "x": 38.58368183290747, "y": -122.50738908690626, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c10f182d-aa76-4633-9a84-f41e20b97da1", "name": "p1rdt6052", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8ac7b79d-e22a-43be-ae62-480551b5dfe1"}}}}, {"uuid": "58116fa8-1381-4b41-93df-1ced21da2f7f", "name": "", "x": 38.58371771254211, "y": -122.50730845553447, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "67bc3ce6-e23d-4899-b0e8-9783225338ff", "name": "p1rdt6046", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "58116fa8-1381-4b41-93df-1ced21da2f7f"}}}}, {"uuid": "bb9375da-bd01-4e61-94d0-a3db80a2f7d9", "name": "", "x": 38.58374436086863, "y": -122.50721642241469, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "87e05b2f-c346-452c-9c72-a6db090c3124", "name": "p1rdt6043", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bb9375da-bd01-4e61-94d0-a3db80a2f7d9"}}}}, {"uuid": "bf36148b-0b67-4e21-ba79-bb14f0d9b9a2", "name": "", "x": 38.613253340793605, "y": -122.45775080611988, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "632d8db5-5220-4188-94f0-f6131253820b", "name": "p1rdt6279", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bf36148b-0b67-4e21-ba79-bb14f0d9b9a2"}}}}, {"uuid": "3aa676ae-ebff-47f5-8913-13e464709b7d", "name": "", "x": 38.58052230427394, "y": -122.51054930766253, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "edf27f1d-b486-434e-92be-963bdeb26090", "name": "p1rdt6501-p1rdt9468x_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3aa676ae-ebff-47f5-8913-13e464709b7d"}}}}, {"uuid": "6eae70b0-8f38-48a1-8e62-c39823216437", "name": "", "x": 38.58140313016848, "y": -122.50982713555175, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e62ba05d-920f-4f55-b1c6-3aa078e0073d", "name": "p1rdt8902-p1rdt9377x_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6eae70b0-8f38-48a1-8e62-c39823216437"}}}}, {"uuid": "9cecf942-f125-4fc9-9f2d-23b443d58d44", "name": "", "x": 38.649913359314574, "y": -122.40176189052858, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8ccc9dcb-3a72-4f11-9bcf-e3a7f1a21985", "name": "p1rdt5195_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9cecf942-f125-4fc9-9f2d-23b443d58d44"}}}}, {"uuid": "54c5be93-4f2a-45c3-9b63-c3f7a44b0522", "name": "", "x": 38.68940056320115, "y": -122.44266975467744, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6b3c997d-cd47-439c-aeb9-326e12c2b869", "name": "p1rdt28lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "54c5be93-4f2a-45c3-9b63-c3f7a44b0522"}}}}, {"uuid": "14523271-bd86-41a7-aced-3e5e00efc0df", "name": "", "x": 38.68955085092013, "y": -122.44265311463495, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8ccef6af-4bf6-44dc-b292-2bf9503a374a", "name": "p1rlv51", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "14523271-bd86-41a7-aced-3e5e00efc0df"}}}}, {"uuid": "d1625529-9e08-4fbd-818b-487e4402e667", "name": "", "x": 38.689199515506125, "y": -122.44267883689947, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b3c62646-6132-41ef-ba14-a06789885cd5", "name": "p1rlv53", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1625529-9e08-4fbd-818b-487e4402e667"}}}}, {"uuid": "ab3986aa-349f-43ce-8609-e96791097421", "name": "", "x": 38.68719967792895, "y": -122.44202477655993, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "61fc3980-6aa4-415c-91c1-10d32c7c359c", "name": "p1rdt29lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ab3986aa-349f-43ce-8609-e96791097421"}}}}, {"uuid": "1232b5c1-d445-40db-859a-e61961a053ad", "name": "", "x": 38.68717368875977, "y": -122.44198213704887, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fec0a162-4b0c-4577-b878-8dbc7c9935fc", "name": "p1rlv52", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1232b5c1-d445-40db-859a-e61961a053ad"}}}}, {"uuid": "c345d1a1-14da-4a8c-a8bb-3e2c621c0204", "name": "", "x": 38.70237353390803, "y": -122.38204661340717, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4d2be3b5-dbfc-4099-af9a-96368e60fe23", "name": "p1rdt30lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c345d1a1-14da-4a8c-a8bb-3e2c621c0204"}}}}, {"uuid": "bc6d9158-f2b3-4cb0-9930-c6984365a7fc", "name": "", "x": 38.702248770449096, "y": -122.38177565760685, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "346dad85-3bf8-41a6-97ea-6b3b40a7f22e", "name": "p1rlv62", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bc6d9158-f2b3-4cb0-9930-c6984365a7fc"}}}}, {"uuid": "a7109162-f295-4719-8eaf-7cdf8aee7649", "name": "", "x": 38.70225996977785, "y": -122.382189570322, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c89ec162-cda3-4c40-8833-3fff085538ba", "name": "p1rdm56", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a7109162-f295-4719-8eaf-7cdf8aee7649"}}}}, {"uuid": "e4ce90f8-02a1-46dd-96c2-c7b8972e5363", "name": "", "x": 38.70215104431212, "y": -122.38204100448107, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "20010301-32ce-4cc0-ab59-04ef3bcd35d7", "name": "p1rlv54", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e4ce90f8-02a1-46dd-96c2-c7b8972e5363"}}}}, {"uuid": "e1200df2-4a75-4e15-8956-eaeb9ff30ccf", "name": "", "x": 38.70125472363682, "y": -122.37955319837823, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "59ff3c1b-38f4-4a33-86fa-e956951c0f2c", "name": "p1rdm58", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e1200df2-4a75-4e15-8956-eaeb9ff30ccf"}}}}, {"uuid": "a1fd30d9-7410-4c78-ba22-7372d3d81998", "name": "", "x": 38.701204180575694, "y": -122.37968411246109, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "36bdbc4e-edfa-425a-8e4c-e6123b567555", "name": "p1rlv55", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a1fd30d9-7410-4c78-ba22-7372d3d81998"}}}}, {"uuid": "4662f7a8-368e-4162-b872-3bc8f29531a6", "name": "", "x": 38.70120618742273, "y": -122.37889811298928, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f678ceb4-b717-44a5-9db9-f698bece6935", "name": "p1rdm60", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4662f7a8-368e-4162-b872-3bc8f29531a6"}}}}, {"uuid": "1b5b11ca-9f19-43b7-b13f-e7164ddc0619", "name": "", "x": 38.701314750425446, "y": -122.37897767463447, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25b891ce-797a-4a4d-b664-4225fba806c4", "name": "p1rlv152", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1b5b11ca-9f19-43b7-b13f-e7164ddc0619"}}}}, {"uuid": "833f8c3b-2661-4791-8f47-042ec9e5cd7a", "name": "", "x": 38.70133109954647, "y": -122.37964493055146, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3510eedd-535c-4e58-b81e-c5ec09030479", "name": "p1rdt31lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "833f8c3b-2661-4791-8f47-042ec9e5cd7a"}}}}, {"uuid": "3acc2e31-a59c-40ed-95ee-1341730b1e49", "name": "", "x": 38.7016002020804, "y": -122.3801252205059, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3a0a4841-bf31-4498-98d9-115cc159981c", "name": "p1rdm59", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3acc2e31-a59c-40ed-95ee-1341730b1e49"}}}}, {"uuid": "d52a647b-da63-4a12-93c7-3e1012a0e903", "name": "", "x": 38.701475019236376, "y": -122.38031030323685, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a32ee184-f677-4333-b7ee-7bc30ab41467", "name": "p1rlv58", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d52a647b-da63-4a12-93c7-3e1012a0e903"}}}}, {"uuid": "a84c9fe6-6be3-4d57-b05a-1e617ace728e", "name": "", "x": 38.70278615488254, "y": -122.38061347297433, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e374d6d6-1e75-4808-b65a-c7033e1bd528", "name": "p1rdt32lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a84c9fe6-6be3-4d57-b05a-1e617ace728e"}}}}, {"uuid": "675a026f-8f3a-4d6a-b336-f2a97a0172d3", "name": "", "x": 38.70279286082068, "y": -122.38071294165577, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ec2c1edd-78b1-4436-85cc-2fbc7d880b87", "name": "p1rlv414", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "675a026f-8f3a-4d6a-b336-f2a97a0172d3"}}}}, {"uuid": "3435bd69-9f3b-43ca-98a0-ec2de3c18d97", "name": "", "x": 38.70248568513053, "y": -122.3805660873002, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cef7aa37-7ca0-4130-9bcd-1804a811245a", "name": "p1rdm61", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3435bd69-9f3b-43ca-98a0-ec2de3c18d97"}}}}, {"uuid": "4e71fca8-0890-4db7-be87-fe294459781e", "name": "", "x": 38.702478683531616, "y": -122.38094565722146, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4694811a-ba43-4c78-b957-5209b1d961e2", "name": "p1rlv56", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4e71fca8-0890-4db7-be87-fe294459781e"}}}}, {"uuid": "4854c4d7-5bd8-4724-af9a-4acd5b27e364", "name": "", "x": 38.70162164245257, "y": -122.38472111973375, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "065c8583-45e5-466c-b4c0-1c66bf970abe", "name": "p1rdt33lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4854c4d7-5bd8-4724-af9a-4acd5b27e364"}}}}, {"uuid": "4199baea-30b5-43b2-b88c-0c1faf4aee21", "name": "", "x": 38.701985008267755, "y": -122.38473348273297, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0f7dbd18-1cbe-49d3-b490-3c46cf8e37f1", "name": "p1rlv170", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4199baea-30b5-43b2-b88c-0c1faf4aee21"}}}}, {"uuid": "78bbc070-dc8e-4410-8d4e-4f606565bf7c", "name": "", "x": 38.70159540402429, "y": -122.38433431596432, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b0538c66-18d7-440e-9efd-6b2945d50f2b", "name": "p1rdm63", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "78bbc070-dc8e-4410-8d4e-4f606565bf7c"}}}}, {"uuid": "fa50dadb-5ee3-46b3-a4eb-9ab06e3f7516", "name": "", "x": 38.70131629597425, "y": -122.38438270952352, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "925cb3b7-4ced-4a36-913f-e6851ed79b98", "name": "p1rlv57", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa50dadb-5ee3-46b3-a4eb-9ab06e3f7516"}}}}, {"uuid": "1d46a1cc-204e-4ea8-8397-e723f39f0b45", "name": "", "x": 38.70167064130821, "y": -122.38493167921865, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cfa2eaff-b163-46ce-b6e5-516680d39bc3", "name": "p1rdm64", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d46a1cc-204e-4ea8-8397-e723f39f0b45"}}}}, {"uuid": "7e6bb48b-c23f-44a8-978e-196d3e00c442", "name": "", "x": 38.70145424916845, "y": -122.38491053257476, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d22bf2f5-74cc-47c7-ae3b-410fba27c113", "name": "p1rlv61", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7e6bb48b-c23f-44a8-978e-196d3e00c442"}}}}, {"uuid": "0bcbb846-2e59-45fb-83c2-51c537155626", "name": "", "x": 38.7023106935151, "y": -122.37870903978225, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "72ee0111-4849-4280-b3c9-c0627d1a6c09", "name": "p1rdm66", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0bcbb846-2e59-45fb-83c2-51c537155626"}}}}, {"uuid": "4825661b-6b25-4827-b894-da341ab1f2d2", "name": "", "x": 38.7024768400754, "y": -122.37889862189955, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b80bdb24-4bbf-4a57-bd5f-6a5ec9d484dd", "name": "p1rlv59", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4825661b-6b25-4827-b894-da341ab1f2d2"}}}}, {"uuid": "363693fc-8724-4e30-9695-ca77f5fdac20", "name": "", "x": 38.70222160936453, "y": -122.37888535297411, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "553a6868-acec-4492-a52d-5aa08414c612", "name": "p1rdt34lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "363693fc-8724-4e30-9695-ca77f5fdac20"}}}}, {"uuid": "236fb449-47ee-42e4-993c-3997b0af760e", "name": "", "x": 38.70217983407473, "y": -122.37897019250839, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "713c1538-ceb4-46df-a996-6c591c0f8e40", "name": "p1rdm67", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "236fb449-47ee-42e4-993c-3997b0af760e"}}}}, {"uuid": "8587aa60-c8a0-494d-8deb-56c4d60053f5", "name": "", "x": 38.70224401225384, "y": -122.37917664191762, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "64a67ed2-a563-4378-b6ac-d9a95339e862", "name": "p1rlv67", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8587aa60-c8a0-494d-8deb-56c4d60053f5"}}}}, {"uuid": "a4d2bd60-6cec-4e24-9421-7fcc9429131d", "name": "", "x": 38.701765866802305, "y": -122.38301785787249, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f98cc066-fca3-4489-9770-047caee3e742", "name": "p1rdt35lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a4d2bd60-6cec-4e24-9421-7fcc9429131d"}}}}, {"uuid": "afa28b82-3110-4dbb-add6-0fa5d3d6fb16", "name": "", "x": 38.701398104123946, "y": -122.38280649214893, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7eb0d1e8-f85e-493e-b69b-26437fdb8ad9", "name": "p1rlv60", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "afa28b82-3110-4dbb-add6-0fa5d3d6fb16"}}}}, {"uuid": "8a2dda54-7737-47d5-82f8-ae2431bf65a0", "name": "", "x": 38.7018668128423, "y": -122.38282546368364, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "23861598-ab3c-4648-9de9-3ee4316f2cb4", "name": "p1rdm69", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8a2dda54-7737-47d5-82f8-ae2431bf65a0"}}}}, {"uuid": "9e951376-bb88-44f2-a35f-e171716fdd96", "name": "", "x": 38.701495649868505, "y": -122.3825066502607, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3e00fd9b-92b3-49c4-bcc2-957b9d2c7bad", "name": "p1rlv65", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9e951376-bb88-44f2-a35f-e171716fdd96"}}}}, {"uuid": "84576a85-50a9-45c2-ab04-9bd1cad70427", "name": "", "x": 38.701815325965796, "y": -122.38044139197483, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6a4fb658-c3ba-428a-82bf-b38ae68dd908", "name": "p1rdt36lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "84576a85-50a9-45c2-ab04-9bd1cad70427"}}}}, {"uuid": "38e99712-7679-4054-95fa-2634f8c37d8a", "name": "", "x": 38.701925218075054, "y": -122.38023741663469, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8300f90c-9a3b-400d-af04-072125dce84f", "name": "p1rlv63", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "38e99712-7679-4054-95fa-2634f8c37d8a"}}}}, {"uuid": "5f6775b3-6eb9-4eae-a0a4-44ca49b16b7e", "name": "", "x": 38.70179061086173, "y": -122.38718468697783, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "074f23bd-2fb2-4480-ae4b-f1c1f754613e", "name": "p1rdm71", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5f6775b3-6eb9-4eae-a0a4-44ca49b16b7e"}}}}, {"uuid": "9a15968a-34bf-40cb-9cbf-7467e5fd4b46", "name": "", "x": 38.70156139001374, "y": -122.38697566423983, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5efd07ee-012a-40a4-97bb-07c1a5ed898c", "name": "p1rlv64", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9a15968a-34bf-40cb-9cbf-7467e5fd4b46"}}}}, {"uuid": "96e3b526-172d-4c2c-aefc-89b5cea154dc", "name": "", "x": 38.7020086293725, "y": -122.38751633252258, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "590e467f-47a6-4c7e-ae3a-83cec8dd87e3", "name": "p1rdm72", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "96e3b526-172d-4c2c-aefc-89b5cea154dc"}}}}, {"uuid": "0997e9e0-7e96-449d-bbc7-a790b2928a00", "name": "", "x": 38.7022335504919, "y": -122.38744541239329, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3fcd1ee-e6e0-4ca3-aacf-cc527b07482a", "name": "p1rlv162", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0997e9e0-7e96-449d-bbc7-a790b2928a00"}}}}, {"uuid": "437cad19-f247-4f11-a9b0-8298d9bda0d4", "name": "", "x": 38.701696448473875, "y": -122.3875919728995, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "90a16370-67f7-4abd-992c-990d1eb8f17e", "name": "p1rdt37lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "437cad19-f247-4f11-a9b0-8298d9bda0d4"}}}}, {"uuid": "e106eb24-7a01-47e1-a694-69754915affd", "name": "", "x": 38.7014985369188, "y": -122.38819919157115, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35807695-5d6d-4544-a748-a96c56b705d1", "name": "p1rdm73", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e106eb24-7a01-47e1-a694-69754915affd"}}}}, {"uuid": "626c124b-2053-457c-ab89-54c6053f1645", "name": "", "x": 38.701670353304884, "y": -122.38831272923629, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6278f6ee-7332-4de8-9d2c-83bb637f489f", "name": "p1rlv457", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "626c124b-2053-457c-ab89-54c6053f1645"}}}}, {"uuid": "5493f5af-7894-49fc-9333-23343effb6c7", "name": "", "x": 38.70178443656836, "y": -122.37918061552492, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "352f8404-f923-468a-92a5-1be2f82ffb97", "name": "p1rdm74", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5493f5af-7894-49fc-9333-23343effb6c7"}}}}, {"uuid": "421b72f0-1f89-4f6c-a02b-5fd568cf930e", "name": "", "x": 38.701833201230905, "y": -122.37934517294276, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e90eb8a2-5db0-4861-96ef-a6991a0386eb", "name": "p1rlv66", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "421b72f0-1f89-4f6c-a02b-5fd568cf930e"}}}}, {"uuid": "33e19b23-b8c7-42b8-babb-ef9a8fd5ed1a", "name": "", "x": 38.701967149573, "y": -122.37911401099093, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "752aca33-7682-4e8c-a8b1-624467e02958", "name": "p1rdt38lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "33e19b23-b8c7-42b8-babb-ef9a8fd5ed1a"}}}}, {"uuid": "4c76e541-3e5a-43d7-aaa5-8196b790733b", "name": "", "x": 38.70235732979096, "y": -122.37866677526797, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2332f175-22ca-4894-b63d-246f5c11c572", "name": "p1rdm75", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c76e541-3e5a-43d7-aaa5-8196b790733b"}}}}, {"uuid": "f32f7bc5-6f90-4089-bec7-957167f1b819", "name": "", "x": 38.70211516673608, "y": -122.37867174586772, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c22aa2c8-a6fc-4b27-a875-e07e3f50ecac", "name": "p1rlv68", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f32f7bc5-6f90-4089-bec7-957167f1b819"}}}}, {"uuid": "da3b2612-960a-4760-b9db-3d1126101c02", "name": "", "x": 38.70178670019972, "y": -122.38549505637238, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "131099af-6f69-4531-bebf-e457ff5d7624", "name": "p1rdm76", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "da3b2612-960a-4760-b9db-3d1126101c02"}}}}, {"uuid": "c4fc819d-a932-4943-a7a8-b0008212d9bb", "name": "", "x": 38.701430782199786, "y": -122.38558924083848, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "876ffb0b-f33c-45b2-a085-7b34103ecffc", "name": "p1rlv69", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c4fc819d-a932-4943-a7a8-b0008212d9bb"}}}}, {"uuid": "0c79e619-8b46-4eb9-bbc3-ee2b7d368108", "name": "", "x": 38.701700119673376, "y": -122.38533518862636, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "623ec6b4-cb70-4437-9d79-5ec577bc3199", "name": "p1rdt39lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0c79e619-8b46-4eb9-bbc3-ee2b7d368108"}}}}, {"uuid": "8d15705c-b29e-458e-bd87-cc5cf3dbeb93", "name": "", "x": 38.70169870333672, "y": -122.38512694165256, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a909c826-1682-47f0-926c-0a67c9ff2a3a", "name": "p1rdm77", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8d15705c-b29e-458e-bd87-cc5cf3dbeb93"}}}}, {"uuid": "64ec693c-962c-4b4a-9a29-91692e5a3162", "name": "", "x": 38.701429210818716, "y": -122.38529025109813, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e53e7714-06d1-4f85-89c5-f152629e8ab7", "name": "p1rlv70", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "64ec693c-962c-4b4a-9a29-91692e5a3162"}}}}, {"uuid": "2e095ced-7dff-4118-9fbf-14b823e34b71", "name": "", "x": 38.6940139373904, "y": -122.37587462456409, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0d08444c-79a3-4ba0-8c69-1855a600dea0", "name": "p1rdt40lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2e095ced-7dff-4118-9fbf-14b823e34b71"}}}}, {"uuid": "0528c2c9-59dc-445a-bef7-3c20da20571c", "name": "", "x": 38.694063719222605, "y": -122.37569816102457, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "46cd88d0-b2c4-492a-af3d-d9ae886d0089", "name": "p1rlv143", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0528c2c9-59dc-445a-bef7-3c20da20571c"}}}}, {"uuid": "8b6a46f9-678f-4bdb-a630-5ce3f058dd3c", "name": "", "x": 38.69389087842103, "y": -122.37592566558304, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "435b1814-b0a6-40e3-a446-efe5b7fce133", "name": "p1rdm78", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8b6a46f9-678f-4bdb-a630-5ce3f058dd3c"}}}}, {"uuid": "a236f6f0-a10f-4bf6-a548-7064bf59a629", "name": "", "x": 38.69394647992354, "y": -122.3762126554526, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d7791de-0cf6-4901-8b95-2d67870f09f5", "name": "p1rlv71", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a236f6f0-a10f-4bf6-a548-7064bf59a629"}}}}, {"uuid": "f171115a-d335-42de-bb3e-cf5763cbcfa4", "name": "", "x": 38.69007704448215, "y": -122.37273530129958, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "793d0bf4-4d9f-4df4-bc95-d528dd7d31d5", "name": "p1rdt41lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f171115a-d335-42de-bb3e-cf5763cbcfa4"}}}}, {"uuid": "856fb6a1-3188-4dd5-8c7a-893d5944fa36", "name": "", "x": 38.68993682745413, "y": -122.37294747048301, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fc710fc3-ae5f-478e-997b-85467db7c93c", "name": "p1rlv72", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "856fb6a1-3188-4dd5-8c7a-893d5944fa36"}}}}, {"uuid": "a8e4f13a-5f5a-476e-b077-18b4f9da8bd1", "name": "", "x": 38.69017871415686, "y": -122.37268089773576, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "188047cd-3f14-4240-91fe-30113d48152b", "name": "p1rlv88", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8e4f13a-5f5a-476e-b077-18b4f9da8bd1"}}}}, {"uuid": "f760aebd-d2f9-4cdb-b451-2aba7e341a70", "name": "", "x": 38.69058527350743, "y": -122.3740266335316, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8fb27dc9-b404-49d1-84dd-0cde418b037d", "name": "p1rdt42lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f760aebd-d2f9-4cdb-b451-2aba7e341a70"}}}}, {"uuid": "cc1fe186-7eff-40cc-9087-6a08b3f0ffe7", "name": "", "x": 38.69045558452261, "y": -122.37389730590256, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "540e0121-fc39-4c2c-9fbc-012c020f5994", "name": "p1rlv86", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc1fe186-7eff-40cc-9087-6a08b3f0ffe7"}}}}, {"uuid": "d3dae137-37c2-4439-a8f7-287d04577a69", "name": "", "x": 38.690475022656685, "y": -122.3741615988237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c5f4300c-037f-42b5-a390-31ec1e8396b3", "name": "p1rdm82", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d3dae137-37c2-4439-a8f7-287d04577a69"}}}}, {"uuid": "ef7eaa33-52e1-434c-ab86-e12bd472fcf6", "name": "", "x": 38.69028492385651, "y": -122.37400227840031, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f4e2991c-1404-44da-bbb5-5a2ebc43bde4", "name": "p1rlv73", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef7eaa33-52e1-434c-ab86-e12bd472fcf6"}}}}, {"uuid": "9138a962-fd56-4f0f-8b21-acd66f15530f", "name": "", "x": 38.69038564798742, "y": -122.37430035768564, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5696ebea-257d-4cc1-9ae4-61c98563b706", "name": "p1rdm86", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9138a962-fd56-4f0f-8b21-acd66f15530f"}}}}, {"uuid": "dbb08176-39c0-4dbc-bf74-460d00d2f441", "name": "", "x": 38.690005204334135, "y": -122.37393572632347, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "afc70b80-ab76-440c-b05b-149458051675", "name": "p1rlv108", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dbb08176-39c0-4dbc-bf74-460d00d2f441"}}}}, {"uuid": "493507a6-2031-493a-ad6b-ef369cb0a201", "name": "", "x": 38.690672040311505, "y": -122.37392991440464, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "49a07eb5-9c9b-479c-a345-b09f72725a21", "name": "p1rdm83", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "493507a6-2031-493a-ad6b-ef369cb0a201"}}}}, {"uuid": "2233f4a7-d806-4388-900b-9d41df1e287d", "name": "", "x": 38.69071765074636, "y": -122.37403300248825, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0ef51371-3fa2-400a-a2b4-3afa97ff2419", "name": "p1rlv75", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2233f4a7-d806-4388-900b-9d41df1e287d"}}}}, {"uuid": "021c8fa6-1ab5-4a3b-b913-398dd6563305", "name": "", "x": 38.69090781102859, "y": -122.374203821834, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c5c96953-6710-4765-b5bd-4359e03e4c63", "name": "p1rlv130", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "021c8fa6-1ab5-4a3b-b913-398dd6563305"}}}}, {"uuid": "04e8ac20-3f95-4330-ad5d-f2b52e4280e4", "name": "", "x": 38.690788633118785, "y": -122.37382541248327, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ae45c08d-f629-4ff9-9c23-838b6e34da88", "name": "p1rdm84", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "04e8ac20-3f95-4330-ad5d-f2b52e4280e4"}}}}, {"uuid": "a8c38f40-05f1-4874-8046-4003ead1c4b8", "name": "", "x": 38.69085275864737, "y": -122.37402032667815, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e4dd2283-6100-48ce-b4bc-0e37b7b4e409", "name": "p1rlv79", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8c38f40-05f1-4874-8046-4003ead1c4b8"}}}}, {"uuid": "6c2fe5a3-78de-415f-9829-d2fa73ee39cb", "name": "", "x": 38.6908423930519, "y": -122.37376745173289, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d93360fa-3106-4444-9488-e73c6997ab71", "name": "p1rdm87", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c2fe5a3-78de-415f-9829-d2fa73ee39cb"}}}}, {"uuid": "59650fe8-d7a3-4405-94bf-13ea9d2f0b8e", "name": "", "x": 38.69085830065978, "y": -122.37390131828276, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "919a48e8-b378-4dd5-8e33-a2602fb58bc0", "name": "p1rlv115", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59650fe8-d7a3-4405-94bf-13ea9d2f0b8e"}}}}, {"uuid": "ca498dfc-d663-4237-a8fa-b38fa64f72e5", "name": "", "x": 38.6907528455112, "y": -122.37219295067007, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b812c54c-1689-47cf-beba-55faea943380", "name": "p1rdm90", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ca498dfc-d663-4237-a8fa-b38fa64f72e5"}}}}, {"uuid": "3eae7d71-071a-434a-936e-6fdec158239c", "name": "", "x": 38.69077167044301, "y": -122.37234226546438, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8e6de569-7f61-439e-a402-850c4f071ab3", "name": "p1rlv117", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3eae7d71-071a-434a-936e-6fdec158239c"}}}}, {"uuid": "0268316d-2bf7-483d-9aa8-55b9a7921399", "name": "", "x": 38.69123428534169, "y": -122.37237669444208, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "274aa0ec-f229-454c-b52d-23130bacb97e", "name": "p1rdt43lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0268316d-2bf7-483d-9aa8-55b9a7921399"}}}}, {"uuid": "3c4120d9-5325-4f01-8812-99a68d778116", "name": "", "x": 38.69134864004529, "y": -122.37238321787136, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0c82df28-72fa-4cf0-a844-8a6bf90e548b", "name": "p1rdm91", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3c4120d9-5325-4f01-8812-99a68d778116"}}}}, {"uuid": "4b05856f-25b9-4d86-8769-f887c528efb3", "name": "", "x": 38.691310990079565, "y": -122.37208458594603, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "54ca5205-5b71-42f2-8e24-c24f768a7a5c", "name": "p1rlv137", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4b05856f-25b9-4d86-8769-f887c528efb3"}}}}, {"uuid": "e736d97a-899f-460c-8076-87e1284f06d6", "name": "", "x": 38.69147492155732, "y": -122.37240511152062, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "acbf36c3-9c53-417f-98c1-fa1b5d4b60f4", "name": "p1rdm89", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e736d97a-899f-460c-8076-87e1284f06d6"}}}}, {"uuid": "36cb466e-9a0d-404d-bb08-cbf2ab13e1cf", "name": "", "x": 38.69153009984452, "y": -122.37261160297146, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5861410e-9d6d-423e-b967-2f2af65610b8", "name": "p1rlv74", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "36cb466e-9a0d-404d-bb08-cbf2ab13e1cf"}}}}, {"uuid": "66056a0b-621e-4e55-bd59-a4d2a449b4ab", "name": "", "x": 38.68938630771864, "y": -122.37020536032335, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c813f8a2-226b-431d-a41a-195cf5e8b01a", "name": "p1rdt44lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "66056a0b-621e-4e55-bd59-a4d2a449b4ab"}}}}, {"uuid": "4d54cf4d-36c1-4945-87e0-3fd1a67d9930", "name": "", "x": 38.68939678035235, "y": -122.37025840439561, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3354497f-6de7-405d-9fca-a9c77463dc27", "name": "p1rlv76", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d54cf4d-36c1-4945-87e0-3fd1a67d9930"}}}}, {"uuid": "e60fd94a-3e00-42ec-9121-2277b286d677", "name": "", "x": 38.690057823403926, "y": -122.37534955818452, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a5151d03-c8b3-41f2-a2cd-743aa8ea0fea", "name": "p1rdm93", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e60fd94a-3e00-42ec-9121-2277b286d677"}}}}, {"uuid": "6aa6e8f9-2731-4404-98c5-2d662c4bad90", "name": "", "x": 38.690220088213884, "y": -122.37535964547071, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f88a22a3-7e6c-4fc5-a8f4-a08cdaa3f5d6", "name": "p1rlv77", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6aa6e8f9-2731-4404-98c5-2d662c4bad90"}}}}, {"uuid": "eb9baf82-ce99-4bd0-b3d6-0bd99fd767c6", "name": "", "x": 38.68996899986402, "y": -122.37559179451463, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4dece5f0-ab6c-40ed-9ec6-0b1377d19e78", "name": "p1rdm94", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eb9baf82-ce99-4bd0-b3d6-0bd99fd767c6"}}}}, {"uuid": "e0a75be7-9eaf-4cdf-895a-1fe48b985539", "name": "", "x": 38.69013175574531, "y": -122.37569386454011, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ee33d90b-2f70-4c9d-863d-6486b95280b8", "name": "p1rlv119", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e0a75be7-9eaf-4cdf-895a-1fe48b985539"}}}}, {"uuid": "f33811d4-8e5e-4b75-98e4-e9e3ee105acd", "name": "", "x": 38.69009885909427, "y": -122.37512675776652, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e276abc-bb27-47e4-9de8-adaccbf964dd", "name": "p1rdt45lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f33811d4-8e5e-4b75-98e4-e9e3ee105acd"}}}}, {"uuid": "68d8f819-82c6-4f68-9d22-add5ca1a825e", "name": "", "x": 38.690225535592255, "y": -122.37469269533909, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a363b9b6-b80f-42cf-942e-17e723376ae6", "name": "p1rdm95", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "68d8f819-82c6-4f68-9d22-add5ca1a825e"}}}}, {"uuid": "1a0ff510-44f5-4e40-bac9-94d0f3d35467", "name": "", "x": 38.690035314507966, "y": -122.37451037852996, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "41960437-e2e6-4746-89c2-81c81602ca1b", "name": "p1rlv132", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1a0ff510-44f5-4e40-bac9-94d0f3d35467"}}}}, {"uuid": "c13588a5-fd65-4f01-ae00-29a3387c1182", "name": "", "x": 38.69396497728804, "y": -122.37461414459213, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2e93e7ed-6686-4fb2-8410-867f2cdbdab2", "name": "p1rdm96", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c13588a5-fd65-4f01-ae00-29a3387c1182"}}}}, {"uuid": "6c7ef76f-bde8-48eb-ad13-be3a39952c52", "name": "", "x": 38.69396985964566, "y": -122.37499754256292, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ae76f058-b79a-4c0f-90be-f9cd7a02bcfc", "name": "p1rlv78", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c7ef76f-bde8-48eb-ad13-be3a39952c52"}}}}, {"uuid": "05ef71ac-c109-4339-afed-73fc1b83ea7f", "name": "", "x": 38.694118107766265, "y": -122.3746013122857, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fdd576f2-a7e2-46eb-b2b0-818c4a97e694", "name": "p1rdm97", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "05ef71ac-c109-4339-afed-73fc1b83ea7f"}}}}, {"uuid": "c48aa8da-1798-4362-b5b7-73a858fb724c", "name": "", "x": 38.69415593578412, "y": -122.37493445252295, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "46ee0e6c-daf7-4412-94a7-5332a6a97656", "name": "p1rlv87", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c48aa8da-1798-4362-b5b7-73a858fb724c"}}}}, {"uuid": "b54fc4bd-352b-4d49-b123-d8ec37be6db1", "name": "", "x": 38.69382389629988, "y": -122.3746653446421, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aacdcb46-43e3-4147-ac25-3a9c1223e13a", "name": "p1rdt46lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b54fc4bd-352b-4d49-b123-d8ec37be6db1"}}}}, {"uuid": "e2d6efe2-38ba-4c3b-b704-9868be4eaae7", "name": "", "x": 38.69332609771847, "y": -122.37479218972346, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "70024d6c-94dd-4367-aeec-92d4bc5eec04", "name": "p1rdm98", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e2d6efe2-38ba-4c3b-b704-9868be4eaae7"}}}}, {"uuid": "948b06e4-a51d-4cd8-9bbb-9811f9996cee", "name": "", "x": 38.69336355649941, "y": -122.37505633665255, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ea9e5f8c-8477-403c-9d3a-911c4e5ab5c8", "name": "p1rlv138", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "948b06e4-a51d-4cd8-9bbb-9811f9996cee"}}}}, {"uuid": "f5d7283b-3a19-4218-880f-573c260dbb07", "name": "", "x": 38.69221243814819, "y": -122.3732880387573, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f031530a-b3fc-4f8e-b0ac-139009d1256c", "name": "p1rdt47lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5d7283b-3a19-4218-880f-573c260dbb07"}}}}, {"uuid": "9763b498-7e70-4ea0-9f4b-4bcd8a123c33", "name": "", "x": 38.692092560795636, "y": -122.3733081060302, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ab7e1b4a-f8ec-4211-b7a0-d7f9057f576a", "name": "p1rlv80", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9763b498-7e70-4ea0-9f4b-4bcd8a123c33"}}}}, {"uuid": "3ebad1dc-7b5d-4af3-8e2f-3e90cf714ce3", "name": "", "x": 38.69236265310078, "y": -122.37325975482375, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "db8f484a-94d5-4d20-8ebf-6708b1601a0d", "name": "p1rlv92", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3ebad1dc-7b5d-4af3-8e2f-3e90cf714ce3"}}}}, {"uuid": "29dc9d0c-aa67-46c7-9211-3b7d980cf123", "name": "", "x": 38.69245991415173, "y": -122.3717601018108, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2f1790fe-a399-46e3-b9e3-5979837777ce", "name": "p1rdt48lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "29dc9d0c-aa67-46c7-9211-3b7d980cf123"}}}}, {"uuid": "74ea0e90-f021-45c2-985c-a3cb88385ae9", "name": "", "x": 38.69259843146321, "y": -122.37185485582063, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ef92e40c-fe3c-4f7f-b844-884e1079e491", "name": "p1rlv81", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "74ea0e90-f021-45c2-985c-a3cb88385ae9"}}}}, {"uuid": "ed97c978-5fd5-4907-ba53-bcb6fa43fb14", "name": "", "x": 38.69231864911266, "y": -122.37177681198607, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a02925cd-7c5b-475f-9e91-30d639bb3c33", "name": "p1rlv120", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ed97c978-5fd5-4907-ba53-bcb6fa43fb14"}}}}, {"uuid": "7335310a-682c-4c5b-b04f-96fb5d0bacdd", "name": "", "x": 38.6924795549249, "y": -122.37153393231236, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fd7286c0-4c57-435f-bed2-fd9a927de8cc", "name": "p1rdm103", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7335310a-682c-4c5b-b04f-96fb5d0bacdd"}}}}, {"uuid": "240896b9-48a3-485b-afb2-209b3f5be2ac", "name": "", "x": 38.69255749370678, "y": -122.3714717809419, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4b02739e-d082-4c54-8deb-8ccc83ab82ab", "name": "p1rlv122", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "240896b9-48a3-485b-afb2-209b3f5be2ac"}}}}, {"uuid": "ed627fe4-0241-47e2-8e66-d0911edf3483", "name": "", "x": 38.693056440809926, "y": -122.37376716989863, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1e5bcc7e-f35c-4bbf-a7ff-a82817488b11", "name": "p1rdt49lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ed627fe4-0241-47e2-8e66-d0911edf3483"}}}}, {"uuid": "9c7705ad-1ce1-4efa-8baa-ac126fb5596d", "name": "", "x": 38.69309336879344, "y": -122.37340286288783, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "da2538bd-189b-4699-823b-ed459d94b422", "name": "p1rlv146", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9c7705ad-1ce1-4efa-8baa-ac126fb5596d"}}}}, {"uuid": "ff84e052-dc91-47d5-bf3f-d8465156a1f6", "name": "", "x": 38.693365493783084, "y": -122.37373395481842, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2409ced2-7817-40af-951f-33d725e9d75a", "name": "p1rdm104", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ff84e052-dc91-47d5-bf3f-d8465156a1f6"}}}}, {"uuid": "7fab99d1-39c7-4a67-a26a-a490bd18a53e", "name": "", "x": 38.69333125539768, "y": -122.3735427494079, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c3ddd704-2530-4392-8e9e-06e047b12f41", "name": "p1rlv82", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7fab99d1-39c7-4a67-a26a-a490bd18a53e"}}}}, {"uuid": "34c1c8cf-98d9-40f7-b221-800f7416fd25", "name": "", "x": 38.69285166538173, "y": -122.3737039387965, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a8385921-c183-4c26-bc99-bf5f0364c18b", "name": "p1rdm105", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "34c1c8cf-98d9-40f7-b221-800f7416fd25"}}}}, {"uuid": "559f04ef-a41b-4fc7-a97a-f8206ab479b3", "name": "", "x": 38.69285080314527, "y": -122.3735429639113, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "096e92a6-ea34-435e-a059-57d5234e1654", "name": "p1rlv107", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "559f04ef-a41b-4fc7-a97a-f8206ab479b3"}}}}, {"uuid": "af091acb-e936-456d-99d0-a49daa8431ea", "name": "", "x": 38.69316443073551, "y": -122.37605094152133, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8208c617-caa9-46a5-b28a-8a5b0d9898a2", "name": "p1rdt50lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "af091acb-e936-456d-99d0-a49daa8431ea"}}}}, {"uuid": "e529b33c-2b5c-4d79-84c2-a61b3b4aecc8", "name": "", "x": 38.69310634340839, "y": -122.3758289932297, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6ae7b1fe-08c4-4848-867e-e2426a325a99", "name": "p1rlv127", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e529b33c-2b5c-4d79-84c2-a61b3b4aecc8"}}}}, {"uuid": "f47c80f2-4d96-4104-a074-926b1622c44f", "name": "", "x": 38.69329674648888, "y": -122.37604581609166, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7948c980-abf7-4357-9ff8-4be9122a3167", "name": "p1rdm107", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f47c80f2-4d96-4104-a074-926b1622c44f"}}}}, {"uuid": "65d557de-e7d9-4492-96b2-9b1bf64cbb04", "name": "", "x": 38.69321156388965, "y": -122.37581260405913, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "24c3e8d8-1520-4a05-84af-a70da6140b4d", "name": "p1rlv83", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65d557de-e7d9-4492-96b2-9b1bf64cbb04"}}}}, {"uuid": "ff8cd1ac-4285-4784-8478-d357b8b3d1ce", "name": "", "x": 38.69331611852453, "y": -122.37629862181807, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6184fe8d-ae60-426a-8c0c-a3cc56c5b67e", "name": "p1rlv123", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ff8cd1ac-4285-4784-8478-d357b8b3d1ce"}}}}, {"uuid": "a9bb9f0a-c1ee-4814-8831-4afd88339097", "name": "", "x": 38.692999373711416, "y": -122.37604839940005, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c2deeb6a-3ea7-44d9-9ee0-b013733dadc4", "name": "p1rdm110", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a9bb9f0a-c1ee-4814-8831-4afd88339097"}}}}, {"uuid": "c03cc8c8-a4ae-4a69-bea0-b62060e3309c", "name": "", "x": 38.692941715957275, "y": -122.37590693919702, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cbdefe7a-517b-495b-88b8-dcf15a9429ff", "name": "p1rlv135", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c03cc8c8-a4ae-4a69-bea0-b62060e3309c"}}}}, {"uuid": "be69abca-c06f-493d-baf9-5ac7009a85d4", "name": "", "x": 38.692481049048034, "y": -122.37128492416231, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "09d7f030-a9b4-4705-82af-6cf140ba64d1", "name": "p1rdt51lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be69abca-c06f-493d-baf9-5ac7009a85d4"}}}}, {"uuid": "462dc74b-1c9a-44f1-a2d7-8681441fa9d6", "name": "", "x": 38.69252947996807, "y": -122.37076308321973, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "55e7538f-4bde-4810-a237-ac0cad7ba805", "name": "p1rlv84", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "462dc74b-1c9a-44f1-a2d7-8681441fa9d6"}}}}, {"uuid": "de0ee001-0810-4d03-9b34-91f9ab41b7cb", "name": "", "x": 38.6922695134408, "y": -122.37101833090937, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0060c029-188f-4725-a935-8d0d9cc892f7", "name": "p1rlv93", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "de0ee001-0810-4d03-9b34-91f9ab41b7cb"}}}}, {"uuid": "a39ff69c-ac92-4842-90cc-f3461b549300", "name": "", "x": 38.69210249623662, "y": -122.37348049869223, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a5dd2d9f-42d5-48c4-b1e1-34ae6aa555df", "name": "p1rdm113", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a39ff69c-ac92-4842-90cc-f3461b549300"}}}}, {"uuid": "90a4515d-a43d-4958-b510-8804455e348b", "name": "", "x": 38.69211341663018, "y": -122.37383686081611, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dcc52dd9-bacb-4e49-a057-d3747f89a7f7", "name": "p1rlv85", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "90a4515d-a43d-4958-b510-8804455e348b"}}}}, {"uuid": "3871a0c1-a5e7-4f51-9ba1-836ee2375900", "name": "", "x": 38.69236400854256, "y": -122.37351271362792, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f42789f3-35c3-4d0d-adda-2044adce92c0", "name": "p1rdm114", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3871a0c1-a5e7-4f51-9ba1-836ee2375900"}}}}, {"uuid": "96de4a8f-3d07-40c8-9322-a027d76c4048", "name": "", "x": 38.69234050594775, "y": -122.37364337983433, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6a1f01bc-d1f1-4d92-b1e2-1f8223624c52", "name": "p1rlv91", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "96de4a8f-3d07-40c8-9322-a027d76c4048"}}}}, {"uuid": "5f73ddf1-4313-4186-92b7-7545d7cb1de3", "name": "", "x": 38.691649262567026, "y": -122.37351497173694, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c70a7331-8c41-4370-b053-3eae432d52ae", "name": "p1rdt52lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5f73ddf1-4313-4186-92b7-7545d7cb1de3"}}}}, {"uuid": "8bbf286f-4457-45c4-a843-ea91d2a17f4d", "name": "", "x": 38.691390973585875, "y": -122.37355569590474, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d2d46cd2-9caf-47a7-b134-a29fccd91b9c", "name": "p1rdm115", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8bbf286f-4457-45c4-a843-ea91d2a17f4d"}}}}, {"uuid": "3cc3de65-5492-4f37-9a52-c57850ceb521", "name": "", "x": 38.691389371784915, "y": -122.37325674863969, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "db2d4080-1f43-47a3-9f3a-e25d1e4f5076", "name": "p1rlv94", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3cc3de65-5492-4f37-9a52-c57850ceb521"}}}}, {"uuid": "dc46f775-942e-4b57-a70e-ebee5a398f00", "name": "", "x": 38.69141053564886, "y": -122.3738429881131, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "85afc796-3fe5-4027-b84e-10d502124636", "name": "p1rlv103", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dc46f775-942e-4b57-a70e-ebee5a398f00"}}}}, {"uuid": "9f9870ad-18ce-4f8e-aafd-27e9a5ce0884", "name": "", "x": 38.691455037994594, "y": -122.373739113497, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4b7dbf54-f6bc-4e20-b2f3-8c63a44dd993", "name": "p1rlv144", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9f9870ad-18ce-4f8e-aafd-27e9a5ce0884"}}}}, {"uuid": "d1dd480a-e298-46fc-bde3-865df51decce", "name": "", "x": 38.69127394993667, "y": -122.37357971347488, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a0d6e82b-cba7-4c7e-8715-d73c3530bad7", "name": "p1rdm116", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1dd480a-e298-46fc-bde3-865df51decce"}}}}, {"uuid": "fd74d192-e637-48d7-8d35-d8fbaeb298f5", "name": "", "x": 38.691299813396455, "y": -122.37336101652306, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "82f19d5c-0941-411d-8baa-3ba029471dae", "name": "p1rlv98", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fd74d192-e637-48d7-8d35-d8fbaeb298f5"}}}}, {"uuid": "b6cdcfae-cff8-4e49-ad15-f9b8de0e80f3", "name": "", "x": 38.69128456220349, "y": -122.37387858172916, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b45d086e-8e0d-42f4-a8ec-6d3a9579a96b", "name": "p1rlv136", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b6cdcfae-cff8-4e49-ad15-f9b8de0e80f3"}}}}, {"uuid": "8ddc7d7f-da7a-419c-9197-b4d0540b8ba5", "name": "", "x": 38.69265743519212, "y": -122.37614335951521, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "329f78a6-af13-4ceb-bc87-4660d497c22e", "name": "p1rdm122", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8ddc7d7f-da7a-419c-9197-b4d0540b8ba5"}}}}, {"uuid": "10bc977a-803e-4f0f-ba15-de1ba41eb822", "name": "", "x": 38.69254776576972, "y": -122.37585684466497, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d3367cc2-b096-4cfb-ae71-038eb9e06b46", "name": "p1rlv125", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10bc977a-803e-4f0f-ba15-de1ba41eb822"}}}}, {"uuid": "ce535576-0e9b-4e7c-b655-cde66068e7df", "name": "", "x": 38.692649343871935, "y": -122.37631591047503, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aa8af0a4-4d55-41e4-83d1-4fe349920e38", "name": "p1rlv148", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ce535576-0e9b-4e7c-b655-cde66068e7df"}}}}, {"uuid": "911b88f2-844c-45e2-ae9a-b20256b0016c", "name": "", "x": 38.69275631408947, "y": -122.37609650577265, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8d595142-3854-4152-b64a-6cda8396a523", "name": "p1rdm121", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "911b88f2-844c-45e2-ae9a-b20256b0016c"}}}}, {"uuid": "c13e3655-f460-4dd1-aecb-af05f8e64a35", "name": "", "x": 38.69270022130948, "y": -122.3757175352468, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "66748ae6-b6ef-4228-bb0f-f9a121f0e1a3", "name": "p1rlv111", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c13e3655-f460-4dd1-aecb-af05f8e64a35"}}}}, {"uuid": "341b2db8-4359-479b-94c7-4683b22cf69d", "name": "", "x": 38.692882349552875, "y": -122.37607241348934, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e2e27276-ea6c-40a3-92d3-4648ec9d235d", "name": "p1rdm123", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "341b2db8-4359-479b-94c7-4683b22cf69d"}}}}, {"uuid": "6513d061-1878-4780-8a4f-3b4468228566", "name": "", "x": 38.692817981929934, "y": -122.37583149911002, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "499fb461-ccb6-436a-8078-eec9beffb4a9", "name": "p1rlv131", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6513d061-1878-4780-8a4f-3b4468228566"}}}}, {"uuid": "5305b25b-d732-4948-8e2a-120bdd4e9ee1", "name": "", "x": 38.69257937121657, "y": -122.37618250960169, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2536a0eb-a35c-40d4-9773-b78379e7481a", "name": "p1rdt53lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5305b25b-d732-4948-8e2a-120bdd4e9ee1"}}}}, {"uuid": "71836ddb-b0aa-495c-a6dd-453ad997e814", "name": "", "x": 38.69241474350349, "y": -122.3762604541736, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e9f62740-f47f-4c97-bae7-4380fe83fcbc", "name": "p1rdm124", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "71836ddb-b0aa-495c-a6dd-453ad997e814"}}}}, {"uuid": "0078fa0b-43fb-419f-bd42-e6fd99824e8f", "name": "", "x": 38.69237796229021, "y": -122.37612278955407, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eb69a6a9-3eaf-4fc3-82be-0eec77455a82", "name": "p1rlv141", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0078fa0b-43fb-419f-bd42-e6fd99824e8f"}}}}, {"uuid": "d7bb4578-cd1e-44b4-a117-fcfb149a76f4", "name": "", "x": 38.69212730175752, "y": -122.37643542970159, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d1071344-55a0-4684-9fbf-5729ec1f21c2", "name": "p1rdm120", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d7bb4578-cd1e-44b4-a117-fcfb149a76f4"}}}}, {"uuid": "f1b03aac-33b7-4dd4-9479-ae369e39696d", "name": "", "x": 38.692072620801916, "y": -122.37632091820853, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "24d75e9a-0249-48ca-ad10-32738bb6a519", "name": "p1rlv89", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f1b03aac-33b7-4dd4-9479-ae369e39696d"}}}}, {"uuid": "a53dd899-1fb1-46fd-b738-e94aa524e450", "name": "", "x": 38.690545533550726, "y": -122.37333707739843, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "57889d14-4aac-4aee-a9e2-677a047e8054", "name": "p1rdt54lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a53dd899-1fb1-46fd-b738-e94aa524e450"}}}}, {"uuid": "d58e8629-1002-48f1-8063-585740bce5a9", "name": "", "x": 38.690111985440346, "y": -122.3736818329642, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e06b2ac7-926e-4caf-afac-386910d4ea5e", "name": "p1rlv90", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d58e8629-1002-48f1-8063-585740bce5a9"}}}}, {"uuid": "e419a944-3cee-407a-af22-419361162c4c", "name": "", "x": 38.69031825985071, "y": -122.37349606102795, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4fe82ede-430d-454d-b9d0-e212d0621ea1", "name": "p1rlv105", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e419a944-3cee-407a-af22-419361162c4c"}}}}, {"uuid": "6f475d0a-f83e-4632-b565-29f42721ed71", "name": "", "x": 38.69409341663082, "y": -122.37388461682215, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "85ad3bf0-7e82-4e32-8106-faddcf725bdf", "name": "p1rdt56lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6f475d0a-f83e-4632-b565-29f42721ed71"}}}}, {"uuid": "20af2ea4-a9f6-4e7d-9cf0-b224359b9df0", "name": "", "x": 38.693962208985816, "y": -122.37409671723277, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "31508077-f731-47cb-94a9-869d7910e406", "name": "p1rlv96", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "20af2ea4-a9f6-4e7d-9cf0-b224359b9df0"}}}}, {"uuid": "a9937757-1991-4707-aad9-564a014df7a1", "name": "", "x": 38.694453827235925, "y": -122.37334499797639, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a60b127d-0530-495e-b3b9-2ebabf070fa1", "name": "p1rdm131", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a9937757-1991-4707-aad9-564a014df7a1"}}}}, {"uuid": "508ecc8e-1f06-4f5a-8b96-19bce68709b4", "name": "", "x": 38.69441870621642, "y": -122.37351778932282, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a11ba246-99d9-4cf5-a557-bec53c75e6fb", "name": "p1rlv804", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "508ecc8e-1f06-4f5a-8b96-19bce68709b4"}}}}, {"uuid": "c05965fd-98d6-49ab-b7ed-438036a0cab8", "name": "", "x": 38.69031197102896, "y": -122.37232328557447, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4bf5bf18-363d-4f4e-bf10-9ffc601c0f30", "name": "p1rdm133", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c05965fd-98d6-49ab-b7ed-438036a0cab8"}}}}, {"uuid": "16c92af6-c70a-4596-b4d0-70df593ccca4", "name": "", "x": 38.69039362804738, "y": -122.37242605719072, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bc4a448a-c6cb-4714-b8e6-b75bc6bc219c", "name": "p1rlv99", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "16c92af6-c70a-4596-b4d0-70df593ccca4"}}}}, {"uuid": "4c1aabbe-0b3e-4cb5-8d6c-f778f2aea5ba", "name": "", "x": 38.69048579257096, "y": -122.37227974908389, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e3367c40-9f47-42d9-b627-bc502b170f2a", "name": "p1rdt58lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c1aabbe-0b3e-4cb5-8d6c-f778f2aea5ba"}}}}, {"uuid": "d328a29f-ee37-4a80-a029-55b6cb1e5ea2", "name": "", "x": 38.69060891171015, "y": -122.37224020218359, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32e76273-c930-4506-9610-8cbfca04af67", "name": "p1rdm134", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d328a29f-ee37-4a80-a029-55b6cb1e5ea2"}}}}, {"uuid": "8a619225-2829-4897-911e-5c71a4d46e70", "name": "", "x": 38.69066464553883, "y": -122.37255017170527, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48d1be49-5aca-4e18-8b85-2a1274b3f26d", "name": "p1rlv101", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8a619225-2829-4897-911e-5c71a4d46e70"}}}}, {"uuid": "4e0e8d3c-7c65-411b-9610-d85c9d4654d5", "name": "", "x": 38.69344092722396, "y": -122.37604456356478, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a7b11b31-78f1-41fa-b511-df76daad0efc", "name": "p1rdm135", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4e0e8d3c-7c65-411b-9610-d85c9d4654d5"}}}}, {"uuid": "e138768b-008a-4552-b69b-4aa8538cf63a", "name": "", "x": 38.69344227667356, "y": -122.37629752630082, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "62a0d673-eaba-4032-9038-8095e2d53999", "name": "p1rlv100", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e138768b-008a-4552-b69b-4aa8538cf63a"}}}}, {"uuid": "fe421763-978a-4d59-8ddf-5f15b7e8f858", "name": "", "x": 38.69361499553134, "y": -122.37604702739569, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8aca9934-9439-4ce6-9ee3-475980324054", "name": "p1rdt59lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fe421763-978a-4d59-8ddf-5f15b7e8f858"}}}}, {"uuid": "1a258a18-33ff-49b6-af22-3f303a0cb210", "name": "", "x": 38.69374688178432, "y": -122.37596141343235, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a415176a-ddab-47a0-9ce7-54c53c4c0f11", "name": "p1rdm136", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1a258a18-33ff-49b6-af22-3f303a0cb210"}}}}, {"uuid": "20b67a46-6909-495f-95d4-ec7eeead6efe", "name": "", "x": 38.69371837494324, "y": -122.37568568791933, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0dbaab50-3abc-4207-82dc-5fcc5be68aad", "name": "p1rlv121", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "20b67a46-6909-495f-95d4-ec7eeead6efe"}}}}, {"uuid": "6ee52466-2ac9-43a0-afb5-55b532be96bf", "name": "", "x": 38.69088191916026, "y": -122.37220729684483, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d2517cea-05d3-4b7f-b9fc-0df0fde81235", "name": "p1rdt60lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6ee52466-2ac9-43a0-afb5-55b532be96bf"}}}}, {"uuid": "ebddd272-2642-4382-93c8-732a7e251cf7", "name": "", "x": 38.690940600905, "y": -122.3719153472003, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "06a432e3-dd37-4c52-b954-6652bb529c8e", "name": "p1rlv102", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ebddd272-2642-4382-93c8-732a7e251cf7"}}}}, {"uuid": "d34b3076-2883-4efd-a327-df823cfc09ce", "name": "", "x": 38.6914549432012, "y": -122.37540639973672, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e53344e0-e328-4acd-b159-e1f8cc246996", "name": "p1rdm138", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d34b3076-2883-4efd-a327-df823cfc09ce"}}}}, {"uuid": "65aeaed9-9c37-4058-be93-e0d605ed9fe2", "name": "", "x": 38.69137249020519, "y": -122.3751541495459, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c76c5b8f-1994-470c-a024-b97c73b9bb41", "name": "p1rlv104", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65aeaed9-9c37-4058-be93-e0d605ed9fe2"}}}}, {"uuid": "03b11a14-27fc-4ea8-843f-062716cd853d", "name": "", "x": 38.69120075557791, "y": -122.37558860981264, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "70f11a44-826f-45b8-9dc3-0f51ce6c9733", "name": "p1rdt61lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "03b11a14-27fc-4ea8-843f-062716cd853d"}}}}, {"uuid": "3143231f-7aee-4214-acd2-38fc402f9656", "name": "", "x": 38.69118822551713, "y": -122.37608712916376, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "022bda10-6b1a-408b-a231-adb63e189d14", "name": "p1rdm139", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3143231f-7aee-4214-acd2-38fc402f9656"}}}}, {"uuid": "13ab2b32-9d28-4487-81f1-93b0f2bdb41c", "name": "", "x": 38.691080519301316, "y": -122.37616855391688, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e5ca78b-6151-4a35-8a04-1bab215f0f10", "name": "p1rlv124", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "13ab2b32-9d28-4487-81f1-93b0f2bdb41c"}}}}, {"uuid": "8313fe5a-77d6-4a80-a7cd-5eef33ed7059", "name": "", "x": 38.693600768265796, "y": -122.37276202285804, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fac6d4e1-b14d-4973-9626-6a4bde2d2a42", "name": "p1rdt63lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8313fe5a-77d6-4a80-a7cd-5eef33ed7059"}}}}, {"uuid": "d428aee0-32db-49a7-b1b4-0ec78e144463", "name": "", "x": 38.69345061514859, "y": -122.37280180665408, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c76fc99c-c160-4ed0-85dd-ec3da962bb24", "name": "p1rlv109", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d428aee0-32db-49a7-b1b4-0ec78e144463"}}}}, {"uuid": "08ec40fb-604c-4457-9274-469a0579239f", "name": "", "x": 38.6932526134289, "y": -122.3728495309013, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25edc94b-a44b-4200-8cde-73941c2818b8", "name": "p1rlv112", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "08ec40fb-604c-4457-9274-469a0579239f"}}}}, {"uuid": "ed2e38b0-cdbf-45f9-9605-3518d40c2b3c", "name": "", "x": 38.69373045846697, "y": -122.37289135400576, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "21b14d95-6634-4f0e-a380-d5e57328d825", "name": "p1rdm143", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ed2e38b0-cdbf-45f9-9605-3518d40c2b3c"}}}}, {"uuid": "73fade0f-c897-4b49-8bd1-e189d59eef12", "name": "", "x": 38.69364972680421, "y": -122.37296105211496, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8b515111-3455-471a-aba8-92c82624a195", "name": "p1rlv139", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "73fade0f-c897-4b49-8bd1-e189d59eef12"}}}}, {"uuid": "b345efc1-ee77-4dc0-8990-db5453affdff", "name": "", "x": 38.6938583426107, "y": -122.37321220673307, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "09182ca9-8ea2-4d1c-9c3e-5850a77c1b66", "name": "p1rdm145", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b345efc1-ee77-4dc0-8990-db5453affdff"}}}}, {"uuid": "d8c833e7-f9ae-40b3-954e-fc43f94fe057", "name": "", "x": 38.69399264902756, "y": -122.37305004970418, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2756378a-0c67-47cf-969d-bdb9e55c8a4b", "name": "p1rlv113", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d8c833e7-f9ae-40b3-954e-fc43f94fe057"}}}}, {"uuid": "1fe742ec-1cfe-4dc9-bc90-282a353ece23", "name": "", "x": 38.69377761075648, "y": -122.37328190461031, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "56bc8935-c658-424c-83d8-0d13bf8d292a", "name": "p1rlv128", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1fe742ec-1cfe-4dc9-bc90-282a353ece23"}}}}, {"uuid": "4fc8e4df-cce5-4fd7-a029-1788d5853eb5", "name": "", "x": 38.694126443783816, "y": -122.37332088048717, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2ae9cb89-7cb8-48c6-a5bc-4178ee364ae8", "name": "p1rdt65lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4fc8e4df-cce5-4fd7-a029-1788d5853eb5"}}}}, {"uuid": "026d3939-bb21-4f6c-855c-b54a7898f18e", "name": "", "x": 38.694562147559466, "y": -122.3733785499152, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "de7551d6-5168-440c-8fe2-9f17e0904c29", "name": "p1rdm147", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "026d3939-bb21-4f6c-855c-b54a7898f18e"}}}}, {"uuid": "e11d221e-d445-4bf9-b913-3b02f6e74ea6", "name": "", "x": 38.69465084301279, "y": -122.37311329835559, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e7ffe87d-4424-4495-83c1-6765d385207c", "name": "p1rlv838", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e11d221e-d445-4bf9-b913-3b02f6e74ea6"}}}}, {"uuid": "9dfdfc2c-853e-4c2b-9385-252d60851f2d", "name": "", "x": 38.767616650522, "y": -122.38054158855523, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dfb9fa3b-c758-4c2e-bc51-f297b1ed21bf", "name": "p1rdt66lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9dfdfc2c-853e-4c2b-9385-252d60851f2d"}}}}, {"uuid": "2538c3eb-b1bc-4ee5-8b00-fa5f18ac8f48", "name": "", "x": 38.767590639077596, "y": -122.38049892417555, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d7934cd3-dcd6-4b67-8206-8a3636b6f75d", "name": "p1rlv114", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2538c3eb-b1bc-4ee5-8b00-fa5f18ac8f48"}}}}, {"uuid": "342627f1-23fc-4fc1-801a-3d315338bc32", "name": "", "x": 38.76719268838157, "y": -122.36058092984808, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bd2d6296-a302-4027-9e5f-c24a56a1a1ac", "name": "p1rdt68lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "342627f1-23fc-4fc1-801a-3d315338bc32"}}}}, {"uuid": "d877fb1b-68a6-4726-933b-8b5b97ff3748", "name": "", "x": 38.76717558814645, "y": -122.36126774194496, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "247e37b3-d6d0-41d7-a6b3-ee29d415da50", "name": "p1rlv118", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d877fb1b-68a6-4726-933b-8b5b97ff3748"}}}}, {"uuid": "da398a4c-6151-40cc-aced-2f61d4aa4fc6", "name": "", "x": 38.689974435374744, "y": -122.37228069359776, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7057debb-bd4d-4156-a253-0f3a14cdd784", "name": "p1rdt69lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "da398a4c-6151-40cc-aced-2f61d4aa4fc6"}}}}, {"uuid": "28269207-9ffd-447f-813e-276f53697dd2", "name": "", "x": 38.68985295036364, "y": -122.37243078084407, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c6c42586-4f46-45c6-910f-90fca771cfd2", "name": "p1rlv129", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "28269207-9ffd-447f-813e-276f53697dd2"}}}}, {"uuid": "750d9357-0219-4629-9238-6ea19caae837", "name": "", "x": 38.68983375524, "y": -122.37221248161097, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "47b7d9f8-ca72-4a77-af67-74ee561f7f10", "name": "p1rlv140", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "750d9357-0219-4629-9238-6ea19caae837"}}}}, {"uuid": "ef755cd7-5294-40c4-91c0-5cf1aacdfadb", "name": "", "x": 38.69318495516089, "y": -122.37483189069003, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "02440066-bc62-4629-96c5-4b497827de5b", "name": "p1rdt70lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef755cd7-5294-40c4-91c0-5cf1aacdfadb"}}}}, {"uuid": "35da9aa8-9637-4cb6-bec3-23001af4bfad", "name": "", "x": 38.69327375078167, "y": -122.3751146121051, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "31dc8280-eb14-4f87-85d7-8eae17013fe7", "name": "p1rlv133", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "35da9aa8-9637-4cb6-bec3-23001af4bfad"}}}}, {"uuid": "e492d455-8b95-4140-896e-122720e148d6", "name": "", "x": 38.69171296593506, "y": -122.37647352235795, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "43d5d2c5-10f6-4e89-91fa-5186f269b659", "name": "p1rdm155", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e492d455-8b95-4140-896e-122720e148d6"}}}}, {"uuid": "e65435ef-abb3-4ac1-89e5-c476f3b500f1", "name": "", "x": 38.69171223017465, "y": -122.37633554599886, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "425bdcfa-9753-4ef5-bb38-9e014ae779dc", "name": "p1rlv134", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e65435ef-abb3-4ac1-89e5-c476f3b500f1"}}}}, {"uuid": "23e3a742-b04c-4e8f-b57d-1ab749ef5509", "name": "", "x": 38.69147969326603, "y": -122.37638705727157, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e71f106d-4b41-405f-bce9-3d06b336a554", "name": "p1rdt71lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "23e3a742-b04c-4e8f-b57d-1ab749ef5509"}}}}, {"uuid": "7f986097-b809-478f-8770-78aac41b94ff", "name": "", "x": 38.69139677338097, "y": -122.37632678646379, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8357e543-eba0-4863-9d95-e34d84a3fae7", "name": "p1rdm156", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7f986097-b809-478f-8770-78aac41b94ff"}}}}, {"uuid": "7ee686cc-84ec-4ff3-9f8f-854f628ac999", "name": "", "x": 38.691395853444895, "y": -122.37615431677973, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1704e67-dfa3-4a6b-a3f4-7ebba9d27537", "name": "p1rlv145", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7ee686cc-84ec-4ff3-9f8f-854f628ac999"}}}}, {"uuid": "0431b8bc-cdf5-4f6e-b49c-eb912990b029", "name": "", "x": 38.69181140426288, "y": -122.37350205897214, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4b59eeab-d997-4186-ab59-0424644d5aeb", "name": "p1rdt72lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0431b8bc-cdf5-4f6e-b49c-eb912990b029"}}}}, {"uuid": "41d95e2a-ac27-4824-827e-3f927ed8ecc1", "name": "", "x": 38.6918879083499, "y": -122.37326787315344, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "070d9a60-c6f2-424c-bd0f-66c52d349f0c", "name": "p1rlv147", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "41d95e2a-ac27-4824-827e-3f927ed8ecc1"}}}}, {"uuid": "bcf6bf7b-ed30-4d11-94d5-a4e84b67a7c4", "name": "", "x": 38.70177173843472, "y": -122.38529743886787, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35f3fd4d-f962-4e4e-89d8-8b41a07ff57d", "name": "p1rdm158", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bcf6bf7b-ed30-4d11-94d5-a4e84b67a7c4"}}}}, {"uuid": "e036b17c-2c45-421a-a0ad-22e901b75472", "name": "", "x": 38.70192489270885, "y": -122.38529750774045, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "063e89ea-6dd0-404f-abfb-21686f3041ed", "name": "p1rlv149", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e036b17c-2c45-421a-a0ad-22e901b75472"}}}}, {"uuid": "dc1f28a1-6b0e-494c-9128-161bf7611a05", "name": "", "x": 38.701762667089824, "y": -122.38553586657494, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4f027d15-df82-4989-93e5-a3b40c862b08", "name": "p1rdt73lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dc1f28a1-6b0e-494c-9128-161bf7611a05"}}}}, {"uuid": "45cb53cc-d42e-45c1-8dea-12d137daf666", "name": "", "x": 38.7017739969935, "y": -122.38573580631073, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7b8d2667-d52b-46b3-ace4-2ad2b4e3050e", "name": "p1rdm159", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "45cb53cc-d42e-45c1-8dea-12d137daf666"}}}}, {"uuid": "ce5d58a5-24be-4e25-851b-2d3cc071d845", "name": "", "x": 38.70192743071094, "y": -122.38578049451348, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5187e006-621e-4c15-9604-0272ae62887c", "name": "p1rlv167", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ce5d58a5-24be-4e25-851b-2d3cc071d845"}}}}, {"uuid": "183e0605-103e-45e9-9163-63593da28942", "name": "", "x": 38.70203671550442, "y": -122.37747640223225, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bb4a799f-0e03-4ba6-b8ce-8f5e117fd2c2", "name": "p1rdm160", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "183e0605-103e-45e9-9163-63593da28942"}}}}, {"uuid": "b8296ec7-3cda-410c-8834-0221de56b03e", "name": "", "x": 38.70208317973028, "y": -122.37774050453031, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0b9979ec-4e43-4feb-a617-28191e9dd9d8", "name": "p1rlv150", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b8296ec7-3cda-410c-8834-0221de56b03e"}}}}, {"uuid": "9c87a630-51fc-447a-8893-3882b474b13b", "name": "", "x": 38.702169092358545, "y": -122.37748277827959, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "37880102-8a9c-4f7b-930a-b29a94241866", "name": "p1rdt74lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9c87a630-51fc-447a-8893-3882b474b13b"}}}}, {"uuid": "4e339b8e-d334-4e6e-b8b0-f354cfa78884", "name": "", "x": 38.70233414912363, "y": -122.37748532373683, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "243cdb10-5012-48b5-809f-1952913bf655", "name": "p1rdm161", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4e339b8e-d334-4e6e-b8b0-f354cfa78884"}}}}, {"uuid": "f5b304ee-ff90-4eae-9d5e-de243e25ae8c", "name": "", "x": 38.702308461860476, "y": -122.3777385521559, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0e326756-7ead-4099-a065-9f2de5693197", "name": "p1rlv169", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5b304ee-ff90-4eae-9d5e-de243e25ae8c"}}}}, {"uuid": "edb1309f-17be-473e-9536-b73605ba9cc7", "name": "", "x": 38.70182389972923, "y": -122.38611886200323, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "699bbf24-59ba-4dba-8bd4-1cf04a7e6e47", "name": "p1rdt75lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "edb1309f-17be-473e-9536-b73605ba9cc7"}}}}, {"uuid": "89e8b4bd-54f6-445d-98bc-cbfabb734b35", "name": "", "x": 38.70198343088721, "y": -122.38614802224237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "345b5c48-cd35-418e-bc08-50c06f5dff09", "name": "p1rlv151", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "89e8b4bd-54f6-445d-98bc-cbfabb734b35"}}}}, {"uuid": "fe33c8c8-9a84-4be4-9d3a-b3f0264e9519", "name": "", "x": 38.701353959316926, "y": -122.37840985382832, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4ecf2223-f120-45b4-8aab-a36d60161aec", "name": "p1rdt76lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fe33c8c8-9a84-4be4-9d3a-b3f0264e9519"}}}}, {"uuid": "8c23f4f5-3dcd-403e-892a-0178fb27e88f", "name": "", "x": 38.70149204336824, "y": -122.37842413503941, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5ccdfbc7-d3a6-4f74-ad32-25ff11a2e3b7", "name": "p1rlv154", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8c23f4f5-3dcd-403e-892a-0178fb27e88f"}}}}, {"uuid": "aeb979fd-4489-43fd-97d9-b0b766b3b211", "name": "", "x": 38.70130360088785, "y": -122.37857526759122, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0bd295ef-2c38-4c6b-915a-73900e920b92", "name": "p1rdm163", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aeb979fd-4489-43fd-97d9-b0b766b3b211"}}}}, {"uuid": "71b04380-49f0-49d3-b901-8a86282d5917", "name": "", "x": 38.70119454861773, "y": -122.37840371014978, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ebbe09dd-7560-4eff-9e32-803f14b4ce7c", "name": "p1rlv153", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "71b04380-49f0-49d3-b901-8a86282d5917"}}}}, {"uuid": "ca1e267b-7f14-4898-83f6-e667edcf4f24", "name": "", "x": 38.702363895820405, "y": -122.37852761379413, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3fd9bf7-ecdd-4dcb-966a-f426d5f2ee81", "name": "p1rdt77lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ca1e267b-7f14-4898-83f6-e667edcf4f24"}}}}, {"uuid": "b239dd78-4f54-4445-a01c-6bb955e0e274", "name": "", "x": 38.70251884097236, "y": -122.37832324388756, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2452d5af-5aba-4d4b-8cd9-27a95fe6b34d", "name": "p1rlv155", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b239dd78-4f54-4445-a01c-6bb955e0e274"}}}}, {"uuid": "447d14e7-4cba-4661-a6d7-a03c610b24ec", "name": "", "x": 38.70156690402656, "y": -122.3772504726202, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e110db24-1653-41b5-8496-821dfff05769", "name": "p1rdm166", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "447d14e7-4cba-4661-a6d7-a03c610b24ec"}}}}, {"uuid": "b80bc469-eb08-4031-91e6-8f576656fd95", "name": "", "x": 38.70172886217702, "y": -122.37720306729005, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7f607e6b-9540-4845-9f0c-6c334eb0e807", "name": "p1rlv156", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b80bc469-eb08-4031-91e6-8f576656fd95"}}}}, {"uuid": "07ca0dfe-b006-46d0-b7d7-c4e4d17b93f4", "name": "", "x": 38.7015268414049, "y": -122.37702834108411, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6f0255b7-5369-40eb-8814-959b0d4245b6", "name": "p1rdt78lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "07ca0dfe-b006-46d0-b7d7-c4e4d17b93f4"}}}}, {"uuid": "aa172697-4d3c-4c21-ad14-791eaaaae1de", "name": "", "x": 38.701501251821085, "y": -122.3767680365563, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c108a0c2-3093-4222-9547-5ac08f6d8a4a", "name": "p1rdm167", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aa172697-4d3c-4c21-ad14-791eaaaae1de"}}}}, {"uuid": "aa54beeb-e05e-40ae-b161-8212e8387d82", "name": "", "x": 38.701672466226256, "y": -122.3767665504658, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a0ae6c02-c29e-4bf9-b1d4-ecc7e37e7de2", "name": "p1rlv159", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aa54beeb-e05e-40ae-b161-8212e8387d82"}}}}, {"uuid": "fbaafc47-9f3c-4277-aaf2-71b0af1b7b7f", "name": "", "x": 38.701573552558834, "y": -122.37796740020737, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "624d03d5-ac53-4d58-ac86-62834fa13c61", "name": "p1rdt79lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fbaafc47-9f3c-4277-aaf2-71b0af1b7b7f"}}}}, {"uuid": "5d4081fd-db54-430c-9651-49ca8ccb19c8", "name": "", "x": 38.70167012893807, "y": -122.378020087898, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "61460072-bdc5-4a70-96fa-8ecfa71623f4", "name": "p1rlv164", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5d4081fd-db54-430c-9651-49ca8ccb19c8"}}}}, {"uuid": "5ddc2017-08f1-4c34-af08-946e29dacc50", "name": "", "x": 38.70151736520935, "y": -122.37810191210743, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "937989ee-4525-4394-b04f-37d77a2c910c", "name": "p1rdm168", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ddc2017-08f1-4c34-af08-946e29dacc50"}}}}, {"uuid": "6e2f44f8-35c0-4ebe-be9e-289c5eb1dec3", "name": "", "x": 38.701243377810904, "y": -122.37795080752997, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4355a473-4643-4f72-afe8-80ce773ca8e8", "name": "p1rlv157", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6e2f44f8-35c0-4ebe-be9e-289c5eb1dec3"}}}}, {"uuid": "f766d922-c367-4ee9-9fb6-96a42381bf45", "name": "", "x": 38.70217305711017, "y": -122.38794268559874, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3ce05c72-facf-447f-ba14-cc2ef64579a8", "name": "p1rdt80lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f766d922-c367-4ee9-9fb6-96a42381bf45"}}}}, {"uuid": "6a03f728-1d34-40e8-9d44-4347597d087c", "name": "", "x": 38.70228005247363, "y": -122.38772102191264, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b1cd7284-17fb-4382-a29d-dd8c5bfd7541", "name": "p1rlv158", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a03f728-1d34-40e8-9d44-4347597d087c"}}}}, {"uuid": "35d2c24a-971e-45b2-a2e3-22eccd876c81", "name": "", "x": 38.7016172629152, "y": -122.37771401826583, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1b610625-09e3-4b72-a8fe-b0c36f5e137c", "name": "p1rdt81lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "35d2c24a-971e-45b2-a2e3-22eccd876c81"}}}}, {"uuid": "f378ac7d-d200-4e41-a406-ab7054564695", "name": "", "x": 38.701704338541916, "y": -122.37767478667475, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fd2fae5a-e5dd-4ad4-8acc-422de00ae83e", "name": "p1rlv160", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f378ac7d-d200-4e41-a406-ab7054564695"}}}}, {"uuid": "85bcfea0-d3da-47ac-b484-16d7e9deb5ef", "name": "", "x": 38.7014372533443, "y": -122.37659609024615, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e2dad274-0d92-42fa-bf1e-a22af034211f", "name": "p1rdm172", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "85bcfea0-d3da-47ac-b484-16d7e9deb5ef"}}}}, {"uuid": "67b2edbf-fb9a-4042-9878-0abb256c07b4", "name": "", "x": 38.701284735816664, "y": -122.3767239154521, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4842819e-3f17-47da-a8bf-c3402c3c00b7", "name": "p1rlv161", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "67b2edbf-fb9a-4042-9878-0abb256c07b4"}}}}, {"uuid": "8faa352b-237f-48a0-9eeb-1ca7041e4a54", "name": "", "x": 38.701286056772844, "y": -122.37644037803527, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9872669f-fd85-458a-8951-ec12965fb42b", "name": "p1rdt82lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8faa352b-237f-48a0-9eeb-1ca7041e4a54"}}}}, {"uuid": "e2c58a52-518f-4c8c-9b38-b8662ad5ade7", "name": "", "x": 38.70116550444912, "y": -122.3763339478172, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "44bdfec0-2d44-442d-b562-ac786c61a76a", "name": "p1rdm173", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e2c58a52-518f-4c8c-9b38-b8662ad5ade7"}}}}, {"uuid": "c8e5702d-def0-482b-8f6a-0620e7bbbeff", "name": "", "x": 38.70118248419553, "y": -122.37613829900104, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b7538477-32ab-4db6-872d-83be7ec89fd9", "name": "p1rlv830", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c8e5702d-def0-482b-8f6a-0620e7bbbeff"}}}}, {"uuid": "3adcb55d-9b1a-46b3-b905-26ad4c6bff2d", "name": "", "x": 38.70185461418825, "y": -122.38682011107082, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8dac1e07-5eb6-4945-a3d9-95b77310358d", "name": "p1rdt83lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3adcb55d-9b1a-46b3-b905-26ad4c6bff2d"}}}}, {"uuid": "4a73fce2-8e99-4a9f-bc75-215c102dbda8", "name": "", "x": 38.702004410202626, "y": -122.38671135342908, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "471bad88-4514-4b02-aa1a-1d2aaa15557f", "name": "p1rlv163", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4a73fce2-8e99-4a9f-bc75-215c102dbda8"}}}}, {"uuid": "fbb96684-d951-42a4-a1f6-ce4c0c253377", "name": "", "x": 38.70161136737774, "y": -122.38394317395175, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d9de64e4-b140-4526-af3c-1f7ceaa687bf", "name": "p1rdm175", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fbb96684-d951-42a4-a1f6-ce4c0c253377"}}}}, {"uuid": "5a097ffc-12e8-463a-bd24-dd8185e42490", "name": "", "x": 38.701999398350054, "y": -122.38404334662313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9e7880c9-0932-4395-abf9-2274e400f280", "name": "p1rlv165", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5a097ffc-12e8-463a-bd24-dd8185e42490"}}}}, {"uuid": "61710186-ca37-4767-9c87-d70a0b168e59", "name": "", "x": 38.70158970365277, "y": -122.38378988145172, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bdb8aaf1-0e21-42e0-a72d-666646561235", "name": "p1rdt84lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "61710186-ca37-4767-9c87-d70a0b168e59"}}}}, {"uuid": "5d8a0ae0-27e3-4461-b370-f4c1e51c40dd", "name": "", "x": 38.701645776351214, "y": -122.38363237450628, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8a6bf0b9-809d-48fb-b8bd-375df052b6cc", "name": "p1rdm176", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5d8a0ae0-27e3-4461-b370-f4c1e51c40dd"}}}}, {"uuid": "209596cf-c99f-4561-a520-381ebd08802a", "name": "", "x": 38.70187142242643, "y": -122.3836994386808, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "21d333f7-7426-4fa6-8ab2-c6118055ece1", "name": "p1rlv166", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "209596cf-c99f-4561-a520-381ebd08802a"}}}}, {"uuid": "a079cab2-18b3-4986-9bd6-e862df6a3992", "name": "", "x": 38.70159534277448, "y": -122.37751697598218, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "40f4034e-c735-419b-80cd-d729d75f4692", "name": "p1rdt85lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a079cab2-18b3-4986-9bd6-e862df6a3992"}}}}, {"uuid": "d5be180e-e603-44df-91b2-15bf09529aaa", "name": "", "x": 38.70142358074945, "y": -122.3774127173029, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "470fe3ed-5b24-438a-ba6d-cdd9f774e5ad", "name": "p1rlv168", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d5be180e-e603-44df-91b2-15bf09529aaa"}}}}, {"uuid": "9ad1b5f7-6de7-45a6-82fa-a019f2a2d2dd", "name": "", "x": 38.69187926915615, "y": -122.40371977394915, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29", "name": "p1rdt89lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9ad1b5f7-6de7-45a6-82fa-a019f2a2d2dd"}}}}, {"uuid": "2dcf3d7d-5bad-4a2a-89df-cc749726edb1", "name": "", "x": 38.69174128032129, "y": -122.40438031441046, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1186295-59ff-48a8-b31d-0f7cd40df1ab", "name": "p1rlv174", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2dcf3d7d-5bad-4a2a-89df-cc749726edb1"}}}}, {"uuid": "b8b95dc9-b571-48bb-b6a5-505568391f8f", "name": "", "x": 38.69209810103375, "y": -122.40366444006949, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "905e9287-bdb6-44e0-b0af-f59ab4ad4d8e", "name": "p1rlv175", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b8b95dc9-b571-48bb-b6a5-505568391f8f"}}}}, {"uuid": "fd83f614-e9b0-4c57-8f6b-38f4f1283fb9", "name": "", "x": 38.69217885130816, "y": -122.4035947777604, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "931c8cee-89fe-447d-8788-af1e5f9f8775", "name": "p1rlv176", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fd83f614-e9b0-4c57-8f6b-38f4f1283fb9"}}}}, {"uuid": "d368bf8f-c6cb-4bf9-ac2a-89d02da7ed90", "name": "", "x": 38.6915327307124, "y": -122.40412907570833, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "090d6084-5cc6-473d-99c0-a6309571d633", "name": "p1rlv177", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d368bf8f-c6cb-4bf9-ac2a-89d02da7ed90"}}}}, {"uuid": "f010dad3-54f5-452e-a9dc-a82317b93f0f", "name": "", "x": 38.69192571259695, "y": -122.40343589909303, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a9debf70-62f4-4870-ad8b-bffc4bc4ad3f", "name": "p1rlv178", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f010dad3-54f5-452e-a9dc-a82317b93f0f"}}}}, {"uuid": "3b0576c8-db7c-411b-9c1c-bfa9f59cbb2b", "name": "", "x": 38.69194238589858, "y": -122.40317129254535, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fb03260b-d7d7-4779-ab2c-37c9a1e34d66", "name": "p1rlv179", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3b0576c8-db7c-411b-9c1c-bfa9f59cbb2b"}}}}, {"uuid": "1d052612-64a8-4667-9de7-cadc1ee125d3", "name": "", "x": 38.690562886551874, "y": -122.39178515337943, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d156fdde-5620-4a6f-b8c1-a3ab986fcc88", "name": "p1rdt150lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d052612-64a8-4667-9de7-cadc1ee125d3"}}}}, {"uuid": "30a89bc3-9ed4-40c7-9ecb-6c588b8c5880", "name": "", "x": 38.69053687920906, "y": -122.3917425303033, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8d3a86df-2ac5-4959-b857-562795ce84ba", "name": "p1rlv285", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "30a89bc3-9ed4-40c7-9ecb-6c588b8c5880"}}}}, {"uuid": "53d8affc-2792-4637-a447-6a4e58c78313", "name": "", "x": 38.66809150084286, "y": -122.48424417400362, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d64d858-a9f7-430f-890e-a456f8913c30", "name": "p1rdt177lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "53d8affc-2792-4637-a447-6a4e58c78313"}}}}, {"uuid": "7607cd8e-f257-4a6d-b55c-9a898d29baf6", "name": "", "x": 38.66811702312487, "y": -122.4842010892547, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "57b88281-b728-4779-82b1-4cc9eb4b41b1", "name": "p1rlv337", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7607cd8e-f257-4a6d-b55c-9a898d29baf6"}}}}, {"uuid": "de0c745d-5ced-43d0-9095-ed76c1548f39", "name": "", "x": 38.681876674272594, "y": -122.49390622766961, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b3314fa8-a838-4028-abb5-043425fd0785", "name": "p1rdt178lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "de0c745d-5ced-43d0-9095-ed76c1548f39"}}}}, {"uuid": "81b033cd-6820-4e9d-9d4a-fe4406f73e5e", "name": "", "x": 38.68190220002097, "y": -122.49386313799357, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e6b2aba6-a289-4a50-a131-2064047d1341", "name": "p1rlv338", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "81b033cd-6820-4e9d-9d4a-fe4406f73e5e"}}}}, {"uuid": "a7b6930a-f33e-4110-8b61-e7e73d1f1ddc", "name": "", "x": 38.66898414531813, "y": -122.45869594003535, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c3e633bc-311e-4698-a413-9c6cf09c42a8", "name": "p1rdt180lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a7b6930a-f33e-4110-8b61-e7e73d1f1ddc"}}}}, {"uuid": "6b1f1532-b5d7-4977-bb8a-eeb24a23de79", "name": "", "x": 38.66899849994981, "y": -122.45874675513116, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bb4797d6-b46e-4058-8985-d9f4b660f0a7", "name": "p1rlv340", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6b1f1532-b5d7-4977-bb8a-eeb24a23de79"}}}}, {"uuid": "ea35ba17-1f44-4509-80ca-f02601f3838a", "name": "", "x": 38.75302665769167, "y": -122.36662619401973, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "05401825-91f8-41f8-9204-ab5806458594", "name": "p1rdt181lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea35ba17-1f44-4509-80ca-f02601f3838a"}}}}, {"uuid": "53a2fe42-5fec-4c3f-bb86-47337d445449", "name": "", "x": 38.75299240671526, "y": -122.36643483348682, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "54f0ea2c-3849-4ff0-ad8c-e3f65515d178", "name": "p1rlv341", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "53a2fe42-5fec-4c3f-bb86-47337d445449"}}}}, {"uuid": "d7210e3a-8ceb-4042-887e-2baf51dd5726", "name": "", "x": 38.75309371224946, "y": -122.36683673194118, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "13754fdb-4039-49fb-b584-8437191dfb2b", "name": "p1rlv342", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d7210e3a-8ceb-4042-887e-2baf51dd5726"}}}}, {"uuid": "953e5e3a-8f85-4748-8249-0703ee775dc5", "name": "", "x": 38.67877405858776, "y": -122.47520020508532, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "db407ddd-fb81-4767-99e1-9aeab12fc770", "name": "p1rdt182lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "953e5e3a-8f85-4748-8249-0703ee775dc5"}}}}, {"uuid": "2f6bbaf5-24aa-40e8-b566-845c59a445a2", "name": "", "x": 38.6787480814273, "y": -122.47515755839895, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0197ef22-9f8f-48a9-84de-663a7ce22773", "name": "p1rlv343", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2f6bbaf5-24aa-40e8-b566-845c59a445a2"}}}}, {"uuid": "35e5b909-f634-4a8b-b66b-4e8bede0808f", "name": "", "x": 38.68506507552232, "y": -122.35588924552482, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4724ea16-dc31-48f8-98b8-b9a223e9a4bb", "name": "p1rdt209lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "35e5b909-f634-4a8b-b66b-4e8bede0808f"}}}}, {"uuid": "1ba1a288-120a-4dbf-bfb8-42f4858ad738", "name": "", "x": 38.68512263068088, "y": -122.3560076800405, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7e1ea241-5329-4db5-996a-df09a9c25687", "name": "p1rlv377", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1ba1a288-120a-4dbf-bfb8-42f4858ad738"}}}}, {"uuid": "4df59d4a-6893-4f1b-b48e-0db3cf09f7af", "name": "", "x": 38.68504927407323, "y": -122.35577838786406, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "50225dcf-40bc-44b5-9dec-072ac5b2334e", "name": "p1rlv379", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4df59d4a-6893-4f1b-b48e-0db3cf09f7af"}}}}, {"uuid": "1885af1b-3bcd-4472-8d94-a5c3f52eb2c6", "name": "", "x": 38.684623418522186, "y": -122.35792952524736, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "05f6a3bf-d465-4f16-8205-616d1f4dd465", "name": "p1rdt210lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1885af1b-3bcd-4472-8d94-a5c3f52eb2c6"}}}}, {"uuid": "61baa391-c9f5-4078-ac02-6dd3b54a83b1", "name": "", "x": 38.684597398947716, "y": -122.35788691809313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d3ff63a0-bf3f-43b0-807c-935467b4fe46", "name": "p1rlv378", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "61baa391-c9f5-4078-ac02-6dd3b54a83b1"}}}}, {"uuid": "10baed55-38a3-44cd-93db-649b00e85837", "name": "", "x": 38.68355474726837, "y": -122.35674337268465, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1d5af6ce-9a4c-414a-bbd8-15d82f50cb57", "name": "p1rdt211lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10baed55-38a3-44cd-93db-649b00e85837"}}}}, {"uuid": "08ef91ea-1f5d-4f98-98c3-eb8f6fa34493", "name": "", "x": 38.68358022206023, "y": -122.35670023394748, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0ee07ef9-b7b0-4457-be1c-78e754dbcfc7", "name": "p1rlv380", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "08ef91ea-1f5d-4f98-98c3-eb8f6fa34493"}}}}, {"uuid": "16164883-d887-47fc-aabd-993c8668dba9", "name": "", "x": 38.70346378054364, "y": -122.37754850885149, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "591461d4-20da-4165-a210-4dbaedd81016", "name": "p1rdt233lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "16164883-d887-47fc-aabd-993c8668dba9"}}}}, {"uuid": "646ac96d-cdc9-49c3-a0f1-3ae8e77da6b9", "name": "", "x": 38.703632263710084, "y": -122.37756607257536, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b54aae8-5a94-4e04-882f-748e1c5f1390", "name": "p1rlv415", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "646ac96d-cdc9-49c3-a0f1-3ae8e77da6b9"}}}}, {"uuid": "6c429ce0-0fef-418f-9d71-d67238478aa4", "name": "", "x": 38.70329902987842, "y": -122.37760346268222, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "99abc7dc-8e15-420f-9bc9-0e6229d4dab3", "name": "p1rlv416", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c429ce0-0fef-418f-9d71-d67238478aa4"}}}}, {"uuid": "9497beca-f842-4ee6-a8e5-508ab4b0b459", "name": "", "x": 38.70344498505631, "y": -122.37793571026356, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "019c88af-413c-4331-84f7-923a1df0a303", "name": "p1rdm434", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9497beca-f842-4ee6-a8e5-508ab4b0b459"}}}}, {"uuid": "0262bf06-9770-4733-99e9-cf98f80a689b", "name": "", "x": 38.703688840272775, "y": -122.37803710181561, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6b33ed36-116b-4741-9374-6927bd537427", "name": "p1rlv412", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0262bf06-9770-4733-99e9-cf98f80a689b"}}}}, {"uuid": "32ce07e1-cf47-4abf-b3bf-24f51f6cfdb1", "name": "", "x": 38.703449772341166, "y": -122.3771421382582, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e3b3eb51-c011-4f2c-8a10-c43c9c86217b", "name": "p1rdm437", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "32ce07e1-cf47-4abf-b3bf-24f51f6cfdb1"}}}}, {"uuid": "294366aa-f7eb-4e04-8d91-2eceb5798884", "name": "", "x": 38.70363888674939, "y": -122.37711749672587, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e7935b9c-b631-432c-a322-9beea73f1fc4", "name": "p1rlv419", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "294366aa-f7eb-4e04-8d91-2eceb5798884"}}}}, {"uuid": "6bcfb4f6-2e39-4863-80fb-e741b4350228", "name": "", "x": 38.70342206460632, "y": -122.37701587380883, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1a713d96-e13f-447e-ab9f-012af3e26afe", "name": "p1rdm438", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6bcfb4f6-2e39-4863-80fb-e741b4350228"}}}}, {"uuid": "d9702311-ea42-4ddf-ae4e-121430adc593", "name": "", "x": 38.703538904912854, "y": -122.37695735772205, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be4d7ed8-5ddd-4127-87ab-eb3f48a580c2", "name": "p1rlv420", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d9702311-ea42-4ddf-ae4e-121430adc593"}}}}, {"uuid": "ad647b8c-5c1a-41de-9194-421c09929204", "name": "", "x": 38.70315939892254, "y": -122.38015776111975, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "adb2d039-e162-43f7-8498-1374581a75fc", "name": "p1rdm439", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ad647b8c-5c1a-41de-9194-421c09929204"}}}}, {"uuid": "760681c9-084f-4e36-a61d-5f3745e7cd14", "name": "", "x": 38.70329481206863, "y": -122.38020259377379, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8408ac87-a086-46bc-9d88-cca79e17dd62", "name": "p1rlv413", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "760681c9-084f-4e36-a61d-5f3745e7cd14"}}}}, {"uuid": "d0c778bc-b90c-47b5-8172-39b840e24616", "name": "", "x": 38.70311258602368, "y": -122.38036119573296, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e480f304-b192-4107-91e1-131d481657b2", "name": "p1rdt234lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d0c778bc-b90c-47b5-8172-39b840e24616"}}}}, {"uuid": "dcdc577e-1e4f-42be-b252-c5958b06d753", "name": "", "x": 38.7029185925103, "y": -122.38063135468911, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "84570b2e-efeb-477e-be1c-43b9d2922fda", "name": "p1rdm440", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dcdc577e-1e4f-42be-b252-c5958b06d753"}}}}, {"uuid": "3fe19806-a4a8-4e42-a1c2-255007fc068e", "name": "", "x": 38.7029199228882, "y": -122.38034781076358, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "49dbdd44-a36a-46b5-aef8-558ef7693315", "name": "p1rlv417", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3fe19806-a4a8-4e42-a1c2-255007fc068e"}}}}, {"uuid": "f7a94d2a-3acd-4984-af0d-c281cf5c686d", "name": "", "x": 38.702857286057856, "y": -122.38150193355499, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d8a6708a-d098-4e02-aac6-4aba7fdc71a5", "name": "p1rdt235lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f7a94d2a-3acd-4984-af0d-c281cf5c686d"}}}}, {"uuid": "25aebc37-4fc6-4413-8a7a-b0c4254ee4f0", "name": "", "x": 38.70300468515236, "y": -122.38157364260027, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "12dcb168-1bfe-448b-8d9a-f5cb4c61aafe", "name": "p1rlv421", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "25aebc37-4fc6-4413-8a7a-b0c4254ee4f0"}}}}, {"uuid": "deb1598d-1ec1-41d1-8f30-df41804e8290", "name": "", "x": 38.70336335384591, "y": -122.37836945726418, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7dd709e3-c5ec-4a01-8297-11f4d1261c3a", "name": "p1rdt236lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "deb1598d-1ec1-41d1-8f30-df41804e8290"}}}}, {"uuid": "4713b3a2-a889-4ee0-b304-c3718091deae", "name": "", "x": 38.70357389491814, "y": -122.3784521142025, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aa7bb51b-8ba8-4a05-872a-7f5ce084fe88", "name": "p1rlv422", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4713b3a2-a889-4ee0-b304-c3718091deae"}}}}, {"uuid": "299ac3a7-1294-41c6-bdfe-f81fcbac0440", "name": "", "x": 38.70326683877779, "y": -122.37832826777388, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6c1e9680-f7de-497c-953a-54f4db2899e2", "name": "p1rlv423", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "299ac3a7-1294-41c6-bdfe-f81fcbac0440"}}}}, {"uuid": "69492088-1302-4501-8eb1-50d1ab439d19", "name": "", "x": 38.69944370500361, "y": -122.41580872476209, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b72726f3-250c-4d98-86bc-5120137bd0f1", "name": "p1rdt237lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "69492088-1302-4501-8eb1-50d1ab439d19"}}}}, {"uuid": "98d78dd8-503b-4dca-8dd9-5465a16c50ee", "name": "", "x": 38.69954841432615, "y": -122.41568889821919, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e1a91c8c-aabd-4fad-8306-908f186a5744", "name": "p1rlv424", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "98d78dd8-503b-4dca-8dd9-5465a16c50ee"}}}}, {"uuid": "85c0e239-6490-4ec7-87dd-d66b31f76a42", "name": "", "x": 38.69927637037365, "y": -122.4159171313363, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "753035df-8705-48eb-92b3-c4bef603b66b", "name": "p1rlv449", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "85c0e239-6490-4ec7-87dd-d66b31f76a42"}}}}, {"uuid": "9558861f-5a1b-4bd9-ba31-559c8aa3081b", "name": "", "x": 38.70680842002751, "y": -122.42486556791981, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "42dff28c-89e7-4b56-bf23-3dcdd3ca216f", "name": "p1rdt251lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9558861f-5a1b-4bd9-ba31-559c8aa3081b"}}}}, {"uuid": "e1935b1d-1c47-4379-ae94-01784a6da9a1", "name": "", "x": 38.70631853264042, "y": -122.42524857112629, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2f771660-4dad-43df-b38b-7da5f6180a25", "name": "p1rlv439", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e1935b1d-1c47-4379-ae94-01784a6da9a1"}}}}, {"uuid": "dee0ea3a-c26d-4a97-b33b-933c3b68df0b", "name": "", "x": 38.70720720644569, "y": -122.42453989136035, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0d665758-71e1-4478-b39d-671f78f623e5", "name": "p1rlv445", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dee0ea3a-c26d-4a97-b33b-933c3b68df0b"}}}}, {"uuid": "ce5d7daa-a960-4160-80bd-5a74b7ce65ff", "name": "", "x": 38.70744608256419, "y": -122.42546956600445, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "acce3105-f519-491c-921a-df1294795742", "name": "p1rlv446", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ce5d7daa-a960-4160-80bd-5a74b7ce65ff"}}}}, {"uuid": "29f44b7f-784a-4c81-83d9-75ac5e82c9e1", "name": "", "x": 38.70608276722945, "y": -122.42495143556884, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "042873fa-10df-4de0-a040-ac429b8bf7d9", "name": "p1rlv447", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "29f44b7f-784a-4c81-83d9-75ac5e82c9e1"}}}}, {"uuid": "5305ea3c-176d-4627-80b2-70f68e3b3249", "name": "", "x": 38.70711624377896, "y": -122.42436810473787, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4bb83d65-630d-4f1d-8e3d-8937a5a05524", "name": "p1rlv448", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5305ea3c-176d-4627-80b2-70f68e3b3249"}}}}, {"uuid": "8c2a657b-ca27-44ca-9109-2bc7768188c8", "name": "", "x": 38.78777229039905, "y": -122.347029423475, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "704fece3-3b83-4c0b-bcd1-d463b3cdaf6b", "name": "p1rdt253lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8c2a657b-ca27-44ca-9109-2bc7768188c8"}}}}, {"uuid": "793f6ac1-bd76-48ee-b6b1-d7f4fea5c5fb", "name": "", "x": 38.78740834836766, "y": -122.34691362308135, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0a778b00-482c-4b81-8213-f17202a105fa", "name": "p1rlv441", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "793f6ac1-bd76-48ee-b6b1-d7f4fea5c5fb"}}}}, {"uuid": "c229e0d5-b101-4f6e-b560-2f2e9acc9bab", "name": "", "x": 38.78809447859801, "y": -122.3471376433436, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "30f29674-3083-4da2-95e2-a1f11a7eb7f8", "name": "p1rlv444", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c229e0d5-b101-4f6e-b560-2f2e9acc9bab"}}}}, {"uuid": "41ca8386-0452-4bf9-be70-2fadb63707ca", "name": "", "x": 38.706805740104386, "y": -122.42594225497479, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "655d8f44-aa2f-4548-a1ca-83fcce9fa7aa", "name": "p1rdt254lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "41ca8386-0452-4bf9-be70-2fadb63707ca"}}}}, {"uuid": "3c269399-d74c-4d59-a8d2-dafb03efc520", "name": "", "x": 38.70689780217361, "y": -122.42576147929557, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6cd667a9-c0ef-49ce-b6ee-7e474d9ae761", "name": "p1rlv442", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3c269399-d74c-4d59-a8d2-dafb03efc520"}}}}, {"uuid": "e57dd29b-9cd7-424b-a501-9ee3096a6870", "name": "", "x": 38.706755483647314, "y": -122.4261421504902, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c2100c17-c0e6-47e9-87f8-72016b22dd4b", "name": "p1rlv443", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e57dd29b-9cd7-424b-a501-9ee3096a6870"}}}}, {"uuid": "538a31a7-d921-47e6-9d70-ef1da95cfcb4", "name": "", "x": 38.68872418378523, "y": -122.3484131511325, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e4c28500-44f7-47c6-b8a8-d1e3468494e3", "name": "p1rdt257lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "538a31a7-d921-47e6-9d70-ef1da95cfcb4"}}}}, {"uuid": "7d61257b-f6a2-48da-9a96-61fb9f4ca7c8", "name": "", "x": 38.68876626401415, "y": -122.34840879300008, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bb46f1ae-0cdb-45d1-b389-639cdf345f8e", "name": "p1rlv452", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7d61257b-f6a2-48da-9a96-61fb9f4ca7c8"}}}}, {"uuid": "80be5501-4a72-4a0b-a037-72d42ecb1ebd", "name": "", "x": 38.69599975733859, "y": -122.39252773638533, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ad9ffaef-f21b-43da-9f67-3a8271edb6bd", "name": "p1rdt258lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "80be5501-4a72-4a0b-a037-72d42ecb1ebd"}}}}, {"uuid": "98e49797-c26c-470d-af4f-29283772b7f7", "name": "", "x": 38.695944209864116, "y": -122.39278871278485, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f6a8a3c7-5165-48b7-8233-30d3af045442", "name": "p1rlv453", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "98e49797-c26c-470d-af4f-29283772b7f7"}}}}, {"uuid": "f90c9866-5b26-4071-a4fc-b0a7d6c52f2d", "name": "", "x": 38.69600232943997, "y": -122.39183378308958, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "85f0d94e-c096-4d53-ae05-f0dc59f73d02", "name": "p1rlv456", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f90c9866-5b26-4071-a4fc-b0a7d6c52f2d"}}}}, {"uuid": "de4f8fed-9482-452a-90c9-5e7caec23923", "name": "", "x": 38.69599911358809, "y": -122.39294923817128, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "76b212f9-2e27-4064-a2c5-079786afb1d1", "name": "p1rlv460", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "de4f8fed-9482-452a-90c9-5e7caec23923"}}}}, {"uuid": "54918463-a6a7-4a05-bf52-c9011253cbfc", "name": "", "x": 38.68471814126827, "y": -122.36995372008337, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c6a0feb3-78c1-4d69-8d18-2a8c3abdcf54", "name": "p1rdt259lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "54918463-a6a7-4a05-bf52-c9011253cbfc"}}}}, {"uuid": "661f61fe-a47e-42bd-9f59-20f5526dc5b4", "name": "", "x": 38.684738584166, "y": -122.36987703423111, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3493b0ed-43a2-4602-a7ad-a817331c9d8e", "name": "p1rlv454", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "661f61fe-a47e-42bd-9f59-20f5526dc5b4"}}}}, {"uuid": "9a532ae9-3d3d-4204-b6db-339efb98c7a9", "name": "", "x": 38.68473945129645, "y": -122.37003799082656, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "552153cc-f5be-42ee-9985-9361c2e7e2a1", "name": "p1rlv455", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9a532ae9-3d3d-4204-b6db-339efb98c7a9"}}}}, {"uuid": "02d1b4b0-73de-4ac2-9167-0f91c0a87843", "name": "", "x": 38.69417505217448, "y": -122.39691277672273, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d8d796d8-6750-4ca5-ae07-1b07331ce6ee", "name": "p1rdt260lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "02d1b4b0-73de-4ac2-9167-0f91c0a87843"}}}}, {"uuid": "c2a504be-9d17-43d9-a528-ac7860584549", "name": "", "x": 38.69444988952913, "y": -122.39658452058625, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ec66e302-748d-4300-ba65-719de0a906bb", "name": "p1rlv458", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c2a504be-9d17-43d9-a528-ac7860584549"}}}}, {"uuid": "3faab6eb-e94a-4a73-8298-c56a3209c291", "name": "", "x": 38.69489061384813, "y": -122.39641983065454, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "76dd0f1b-4109-4707-a547-f0ab1b6e148f", "name": "p1rlv461", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3faab6eb-e94a-4a73-8298-c56a3209c291"}}}}, {"uuid": "e28b20ea-136d-493a-b93f-1d8c8d2e0275", "name": "", "x": 38.69609340912066, "y": -122.39266578758262, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fe4ec5b6-61fb-4b66-9e43-19d81af88966", "name": "p1rdt261lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e28b20ea-136d-493a-b93f-1d8c8d2e0275"}}}}, {"uuid": "32b9738c-437a-49e1-bcf9-ba63fbef1757", "name": "", "x": 38.69613569697208, "y": -122.39266409008623, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4c112196-bcbc-41bc-99a9-f3657c335c7a", "name": "p1rlv459", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "32b9738c-437a-49e1-bcf9-ba63fbef1757"}}}}, {"uuid": "fc0b9de9-847e-4f4c-9650-639faab16240", "name": "", "x": 38.69746455104433, "y": -122.39109295618859, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "30952601-1479-4770-9b77-9fe3465310b7", "name": "p1rdt262lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fc0b9de9-847e-4f4c-9650-639faab16240"}}}}, {"uuid": "4bce323d-cade-48f6-bd80-19de38309d9c", "name": "", "x": 38.697566588571334, "y": -122.39110756675504, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9176da24-7eb5-4b0b-99dd-886c3f974798", "name": "p1rlv462", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4bce323d-cade-48f6-bd80-19de38309d9c"}}}}, {"uuid": "614237e9-0299-4752-b3bd-ac572efbc93f", "name": "", "x": 38.69741333633857, "y": -122.39109736665547, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "895d0235-3ee6-4f06-9978-9d615d721ebd", "name": "p1rlv464", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "614237e9-0299-4752-b3bd-ac572efbc93f"}}}}, {"uuid": "85ef6f5a-7f9c-417e-a030-2cddbc51d968", "name": "", "x": 38.69796207835795, "y": -122.39189498505252, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2c7501f4-0394-4766-a3c5-b17fda7f3817", "name": "p1rdt263lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "85ef6f5a-7f9c-417e-a030-2cddbc51d968"}}}}, {"uuid": "020235d3-cf73-4472-bd30-ddd25a084052", "name": "", "x": 38.69793607105191, "y": -122.39185235758016, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ff9d9cca-1878-478d-a190-b58c9098f13e", "name": "p1rlv463", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "020235d3-cf73-4472-bd30-ddd25a084052"}}}}, {"uuid": "a47e9ee1-03b2-4ff9-935d-f8a781ece2cd", "name": "", "x": 38.7505574694735, "y": -122.41550076869619, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d33a03d6-fddc-4e47-8018-cd7d290b30b0", "name": "p1rdt270lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a47e9ee1-03b2-4ff9-935d-f8a781ece2cd"}}}}, {"uuid": "dbb5ba0e-ba1e-4371-bcd8-6e1f788e6252", "name": "", "x": 38.75057184305653, "y": -122.41555163249289, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2e589527-d388-4364-87d2-2f4af1a14509", "name": "p1rlv474", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dbb5ba0e-ba1e-4371-bcd8-6e1f788e6252"}}}}, {"uuid": "18d6fe25-b7b6-445a-ae4b-e251280306d0", "name": "", "x": 38.77190208512443, "y": -122.36444610004378, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6715c6a-6869-412a-8e59-e5c2eb03c56b", "name": "p1rdt275lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "18d6fe25-b7b6-445a-ae4b-e251280306d0"}}}}, {"uuid": "f5d52a4c-e524-4515-8bd6-5a25557f9ba1", "name": "", "x": 38.77188833047837, "y": -122.36449725722824, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cb55ec0b-b6f7-48a7-8dae-dda95fc34499", "name": "p1rlv480", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5d52a4c-e524-4515-8bd6-5a25557f9ba1"}}}}, {"uuid": "e49c6293-1f6d-43c7-9f99-3bad9fb91f2e", "name": "", "x": 38.6981164551154, "y": -122.40319272296294, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b478b4f8-8d5e-47b0-a56a-8b991dc8d944", "name": "p1rdt276lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e49c6293-1f6d-43c7-9f99-3bad9fb91f2e"}}}}, {"uuid": "c92307a0-d75e-4ba8-8c7a-0fc694691602", "name": "", "x": 38.69831357847344, "y": -122.40315284432228, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8d9e77ad-42c6-4413-96e6-debfed3c442a", "name": "p1rlv481", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c92307a0-d75e-4ba8-8c7a-0fc694691602"}}}}, {"uuid": "78102e48-a7be-4d96-894e-01561d3adb23", "name": "", "x": 38.697080868964996, "y": -122.39900074624246, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "24486e15-ff1e-45b3-aa02-703263f04844", "name": "p1rdt277lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "78102e48-a7be-4d96-894e-01561d3adb23"}}}}, {"uuid": "4daf40d1-d481-436a-ab75-fc0ab9938839", "name": "", "x": 38.696472678672315, "y": -122.39914337613104, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8d4b708f-cc15-4ee3-87e0-4d26fec02f1e", "name": "p1rlv482", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4daf40d1-d481-436a-ab75-fc0ab9938839"}}}}, {"uuid": "7a0f4694-1f59-45db-ac24-c397b84f74bf", "name": "", "x": 38.682836254431685, "y": -122.35413994526482, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a8af5824-d5d7-4cba-98b7-d72993909f22", "name": "p1rdt278lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7a0f4694-1f59-45db-ac24-c397b84f74bf"}}}}, {"uuid": "ae9edf40-7cf8-4a90-b1fb-e195a11a717e", "name": "", "x": 38.682850654364266, "y": -122.35419074861349, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d059a618-6f09-404b-b1a0-0e7aa0c55c45", "name": "p1rlv483", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ae9edf40-7cf8-4a90-b1fb-e195a11a717e"}}}}, {"uuid": "5e812994-8ece-4fc5-8b76-348599a6e2ce", "name": "", "x": 38.696321369018115, "y": -122.40303140946239, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2d6856ee-d113-45ec-99e0-8a915a89a56c", "name": "p1rdm508", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5e812994-8ece-4fc5-8b76-348599a6e2ce"}}}}, {"uuid": "b52b0521-4625-42cf-a321-7a6ef164fc92", "name": "", "x": 38.6966231134774, "y": -122.40212045173747, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fde62b60-c5f6-44d6-b2f2-211c21b02033", "name": "p1rlv484", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b52b0521-4625-42cf-a321-7a6ef164fc92"}}}}, {"uuid": "ef878753-5b7b-4b1e-adac-6f6766e7a2bf", "name": "", "x": 38.69619520198978, "y": -122.40301175619707, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4bf679fe-712f-4db6-9df9-debb29b7ee73", "name": "p1rdt279lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef878753-5b7b-4b1e-adac-6f6766e7a2bf"}}}}, {"uuid": "38f0df30-9996-4460-baaf-8cf45c0bdea2", "name": "", "x": 38.69610445115518, "y": -122.40290672048755, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9c3bf9bd-d12a-47d7-b2e2-3f31f3a0419b", "name": "p1rdm509", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "38f0df30-9996-4460-baaf-8cf45c0bdea2"}}}}, {"uuid": "6a1f742e-0281-41f8-a274-ca742d98c351", "name": "", "x": 38.69640566539714, "y": -122.40189227549035, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f8d2c379-7e19-46c4-8c6e-533fa9db7764", "name": "p1rlv485", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a1f742e-0281-41f8-a274-ca742d98c351"}}}}, {"uuid": "958a623e-a829-4d3b-b310-b6a20945b961", "name": "", "x": 38.762845986496735, "y": -122.35672935763573, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e4eafd2-0f68-4e2a-a62c-89cb877004d4", "name": "p1rdt280lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "958a623e-a829-4d3b-b310-b6a20945b961"}}}}, {"uuid": "13e2dd00-cffc-4b7a-8ed9-55c3876df7bd", "name": "", "x": 38.762552303891766, "y": -122.35627912797126, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a54b2228-9e7d-4e6b-939d-ab2765454522", "name": "p1rlv486", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "13e2dd00-cffc-4b7a-8ed9-55c3876df7bd"}}}}, {"uuid": "4ee1cc19-733f-450e-b658-7f8074b32937", "name": "", "x": 38.75426623013744, "y": -122.36483936695494, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3e01a56d-1bfc-4169-9c3e-1373f9dbeb38", "name": "p1rdt281lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ee1cc19-733f-450e-b658-7f8074b32937"}}}}, {"uuid": "63783525-ad46-428b-b194-e5e2392a991c", "name": "", "x": 38.754777075984755, "y": -122.36484236876056, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be2d5799-907e-46fd-a389-120aea352775", "name": "p1rlv487", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "63783525-ad46-428b-b194-e5e2392a991c"}}}}, {"uuid": "e050f717-a215-4406-852a-29b4e392e4c5", "name": "", "x": 38.7537136313869, "y": -122.3648287764951, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "97c38794-7c60-4ff8-b09b-7503c9604409", "name": "p1rlv523", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e050f717-a215-4406-852a-29b4e392e4c5"}}}}, {"uuid": "3f49fa54-5e18-452b-ac04-7e82caec4a6b", "name": "", "x": 38.723225529795435, "y": -122.41097744489697, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7a8430e1-656f-4fe2-a11b-00adf429d75d", "name": "p1rdt297lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3f49fa54-5e18-452b-ac04-7e82caec4a6b"}}}}, {"uuid": "800c1fd5-f75b-4ea4-8955-de1e60878b43", "name": "", "x": 38.72307124027624, "y": -122.41075789575113, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bef074be-aac4-4d82-a832-641729756802", "name": "p1rlv524", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "800c1fd5-f75b-4ea4-8955-de1e60878b43"}}}}, {"uuid": "40ccb968-5212-4fa6-8793-3d76b678e286", "name": "", "x": 38.72334331826878, "y": -122.41110077065662, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3ab8e220-faf9-4108-80f8-22d2fe326c3d", "name": "p1rlv526", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "40ccb968-5212-4fa6-8793-3d76b678e286"}}}}, {"uuid": "429e93d6-a631-4ce5-9c3c-aa5a0aa6cedf", "name": "", "x": 38.72448847815554, "y": -122.41245231274745, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33e93250-9c11-4650-9469-412129855857", "name": "p1rdt298lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "429e93d6-a631-4ce5-9c3c-aa5a0aa6cedf"}}}}, {"uuid": "0688d8cc-a312-4660-8627-495ceab33df7", "name": "", "x": 38.72453056079826, "y": -122.41244798967669, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a42f8b99-82c6-4c90-81ea-6ccb38eacfab", "name": "p1rlv525", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0688d8cc-a312-4660-8627-495ceab33df7"}}}}, {"uuid": "fab5aa33-d64c-4dcc-b8ff-14c2773f63ad", "name": "", "x": 38.670540900167985, "y": -122.47976645470963, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6353ab92-f66f-47d8-97ac-058cf030ff82", "name": "p1rdt303lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fab5aa33-d64c-4dcc-b8ff-14c2773f63ad"}}}}, {"uuid": "9eb06290-2b92-41e0-9020-16bf69db06ca", "name": "", "x": 38.67056642076858, "y": -122.47972336691173, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32a1d9d7-31c7-4def-88d4-e4d41bd21572", "name": "p1rlv531", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9eb06290-2b92-41e0-9020-16bf69db06ca"}}}}, {"uuid": "8fb02675-4391-4938-a19f-1fd47ec0ceda", "name": "", "x": 38.67227127773109, "y": -122.47626596196271, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6a22ac71-bf3a-4016-86ce-fb25f471be5b", "name": "p1rdt304lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8fb02675-4391-4938-a19f-1fd47ec0ceda"}}}}, {"uuid": "98e5c374-ce1a-433a-8af6-cdab22541808", "name": "", "x": 38.67217810662493, "y": -122.4762166840671, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1362feeb-2e2c-4dd1-9f49-239c952c6120", "name": "p1rlv532", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "98e5c374-ce1a-433a-8af6-cdab22541808"}}}}, {"uuid": "b1b16ed0-c803-4ef8-af4d-bcfbdb7bd045", "name": "", "x": 38.67233171369118, "y": -122.47630752878543, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1f79bc5f-375f-4ecd-b828-eb7b137d7cab", "name": "p1rlv533", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b1b16ed0-c803-4ef8-af4d-bcfbdb7bd045"}}}}, {"uuid": "98bbd597-db60-4a2a-8e22-d8fd7c316c09", "name": "", "x": 38.67073161586084, "y": -122.47582091564139, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "90948977-fe1a-43b3-a8a4-86c080ae4906", "name": "p1rdt305lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "98bbd597-db60-4a2a-8e22-d8fd7c316c09"}}}}, {"uuid": "7f11a1c9-7fc0-498c-a911-6ffb6fc8d6be", "name": "", "x": 38.67104039312592, "y": -122.47571918109917, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0eb7074c-0745-4089-9329-aa3495f9b460", "name": "p1rlv534", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7f11a1c9-7fc0-498c-a911-6ffb6fc8d6be"}}}}, {"uuid": "ce2d9c5a-57c3-4ef1-b7d9-f4624daa6515", "name": "", "x": 38.67049996143512, "y": -122.47578059875961, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9cc91945-564c-4ace-bb53-77150b107b41", "name": "p1rlv535", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ce2d9c5a-57c3-4ef1-b7d9-f4624daa6515"}}}}, {"uuid": "58063c7b-e265-41f6-9754-559892ab8f15", "name": "", "x": 38.6707171128322, "y": -122.47597443436533, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d2ea78a8-b9c5-4760-b153-51b45565069e", "name": "p1rlv536", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "58063c7b-e265-41f6-9754-559892ab8f15"}}}}, {"uuid": "3a81837a-b6e1-4684-9525-903af091b574", "name": "", "x": 38.671226697580636, "y": -122.49048662526606, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "53eba878-66fa-4d30-8af4-1f583abe5f16", "name": "p1rdt306lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3a81837a-b6e1-4684-9525-903af091b574"}}}}, {"uuid": "31601fbd-a6ef-4c97-97da-e3c1cee1ddcf", "name": "", "x": 38.67124103844962, "y": -122.49053744844569, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9f2dfc9e-0b72-4465-b46a-d4e2a7a08f64", "name": "p1rlv537", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "31601fbd-a6ef-4c97-97da-e3c1cee1ddcf"}}}}, {"uuid": "1447dd15-b11d-4b92-aee8-fa7c9a86ea06", "name": "", "x": 38.685116671576026, "y": -122.45208329969167, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b8e448ea-e66d-4e16-80c0-8e742d7cac55", "name": "p1rdt335lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1447dd15-b11d-4b92-aee8-fa7c9a86ea06"}}}}, {"uuid": "20dab0fc-7fd8-4fca-bbe2-8c2946d2e18d", "name": "", "x": 38.68493681955931, "y": -122.45218585265648, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75628d41-a82d-4425-8aa2-9f377c771a4c", "name": "p1rlv588", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "20dab0fc-7fd8-4fca-bbe2-8c2946d2e18d"}}}}, {"uuid": "e11e5579-8701-4498-9418-0b99d6060f71", "name": "", "x": 38.6854049831095, "y": -122.45209030229843, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7a1c60be-f1a1-48d6-b396-4cca6d8c4e62", "name": "p1rlv589", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e11e5579-8701-4498-9418-0b99d6060f71"}}}}, {"uuid": "d9e96ec4-e74e-4618-9ee7-65d34c892888", "name": "", "x": 38.685061363444774, "y": -122.45183997708463, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "81ce208e-7244-418a-9867-b55b95ba0716", "name": "p1rlv590", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d9e96ec4-e74e-4618-9ee7-65d34c892888"}}}}, {"uuid": "10862e71-ec7d-4875-839a-324f8b84aa90", "name": "", "x": 38.68749417205864, "y": -122.45093337637859, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35993388-185f-4d1d-9dcb-16eb7556728f", "name": "p1rdt374lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10862e71-ec7d-4875-839a-324f8b84aa90"}}}}, {"uuid": "5987b6b3-bd40-4102-a885-a2b6b4a0a8d3", "name": "", "x": 38.687468186113925, "y": -122.45089073343217, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6e58890e-e6ce-4dda-91c0-5ccfdb5c420d", "name": "p1rlv657", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5987b6b3-bd40-4102-a885-a2b6b4a0a8d3"}}}}, {"uuid": "4b47f1f1-e215-42c1-aa5a-82bd5ed4ed38", "name": "", "x": 38.687021635585204, "y": -122.45201778533264, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d354e81e-b007-4bbe-b1db-50d7afacd0e0", "name": "p1rdt376lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4b47f1f1-e215-42c1-aa5a-82bd5ed4ed38"}}}}, {"uuid": "540e4606-3bc9-471d-b851-891dddd4bfbf", "name": "", "x": 38.68703599315794, "y": -122.452068611773, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "15751ee2-6783-472f-ad57-ec978234fec4", "name": "p1rlv660", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "540e4606-3bc9-471d-b851-891dddd4bfbf"}}}}, {"uuid": "b09e519e-2b26-438c-b80c-dc0e164fea9c", "name": "", "x": 38.67908332659903, "y": -122.51991969614502, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8569c197-174f-46ef-96c2-e0c674d7b046", "name": "p1rdt383lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b09e519e-2b26-438c-b80c-dc0e164fea9c"}}}}, {"uuid": "35e022ae-36d9-4824-88d4-cf5c8316580d", "name": "", "x": 38.67905736564, "y": -122.51987703293702, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eb25bf05-ce7f-405a-8c17-fd166748f7d3", "name": "p1rlv672", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "35e022ae-36d9-4824-88d4-cf5c8316580d"}}}}, {"uuid": "72ad716e-f1d2-48f5-a747-b3d15a844fd9", "name": "", "x": 38.679023967859024, "y": -122.52913908431695, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c56b4839-f007-4c9b-93a7-9147399f983f", "name": "p1rdt384lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "72ad716e-f1d2-48f5-a747-b3d15a844fd9"}}}}, {"uuid": "4cc9de64-df79-4551-84a0-ef1dbd2fec0c", "name": "", "x": 38.67837935182842, "y": -122.52878337051408, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "31d3267c-7020-4660-9a0b-49cd9d94a5d0", "name": "p1rlv673", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4cc9de64-df79-4551-84a0-ef1dbd2fec0c"}}}}, {"uuid": "17902503-2dce-426d-8ec3-66c36f03f7c9", "name": "", "x": 38.71691820009889, "y": -122.41937517163929, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "579c3e97-d1dc-4306-91e6-4cbbed29f882", "name": "p1rdt385lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "17902503-2dce-426d-8ec3-66c36f03f7c9"}}}}, {"uuid": "0575f243-1568-49fc-92d7-26cd6182fbca", "name": "", "x": 38.716892202729326, "y": -122.41933252291317, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "449992d6-a91b-40ea-9792-5166a5f2c849", "name": "p1rlv674", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0575f243-1568-49fc-92d7-26cd6182fbca"}}}}, {"uuid": "3a464616-ff46-4e66-bc71-73f7cb619077", "name": "", "x": 38.6691571170927, "y": -122.47438402684668, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "29a78735-964b-4381-bea0-01e5b1b79be9", "name": "p1rdt414lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3a464616-ff46-4e66-bc71-73f7cb619077"}}}}, {"uuid": "59455f0e-ff8f-4b31-b73e-898b6fbaf586", "name": "", "x": 38.669005790542414, "y": -122.47417070346637, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "93069f0f-fce7-47cd-b7b3-77e861f59573", "name": "p1rlv716", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59455f0e-ff8f-4b31-b73e-898b6fbaf586"}}}}, {"uuid": "4d4d97a1-ea59-48d6-b28a-5ea47726fe0d", "name": "", "x": 38.66935018999187, "y": -122.47460499537559, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1fdcbc55-681f-4fe5-8142-4945b25f6fef", "name": "p1rlv726", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d4d97a1-ea59-48d6-b28a-5ea47726fe0d"}}}}, {"uuid": "7488598b-5c4a-42eb-9cbf-5b2ea2c5d1db", "name": "", "x": 38.67353500851874, "y": -122.4699836494228, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "789d55de-619d-43cd-b056-ebe1be4c2dea", "name": "p1rdt415lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7488598b-5c4a-42eb-9cbf-5b2ea2c5d1db"}}}}, {"uuid": "8f512abc-7a0e-4beb-995e-afdea04ecb04", "name": "", "x": 38.67341206301482, "y": -122.47006900065233, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dd8fd159-f747-4ee4-a426-787f4eef4b42", "name": "p1rlv717", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8f512abc-7a0e-4beb-995e-afdea04ecb04"}}}}, {"uuid": "a5d9e4a8-f3b6-4cdb-9db1-c58f8b044a15", "name": "", "x": 38.673699700951325, "y": -122.46990593984998, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c3658479-7369-4bd9-be54-e7768c93a808", "name": "p1rlv724", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a5d9e4a8-f3b6-4cdb-9db1-c58f8b044a15"}}}}, {"uuid": "e0b96858-aa03-46db-b180-5ee0b94c7331", "name": "", "x": 38.67143528847217, "y": -122.47049470940273, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "473f5822-3412-4f3d-836e-f62314efa5b2", "name": "p1rdt416lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e0b96858-aa03-46db-b180-5ee0b94c7331"}}}}, {"uuid": "0afc18f9-d7cd-4f29-9b20-fee7da27741d", "name": "", "x": 38.67144963800081, "y": -122.4705455286412, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c4a1453b-98a3-4c2d-8ac2-c8b2ab1bfa4f", "name": "p1rlv718", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0afc18f9-d7cd-4f29-9b20-fee7da27741d"}}}}, {"uuid": "f4989904-872f-47d3-8701-93590820f835", "name": "", "x": 38.67352761620833, "y": -122.47084715807108, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "98bb09be-6506-49e8-8fd8-1a01d6861162", "name": "p1rdt417lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f4989904-872f-47d3-8701-93590820f835"}}}}, {"uuid": "e5c56170-5e6a-4e5e-93de-83a3668da549", "name": "", "x": 38.673541965589685, "y": -122.47089797885619, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d3153167-8b4c-40e4-abb7-3bdef86950c3", "name": "p1rlv719", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e5c56170-5e6a-4e5e-93de-83a3668da549"}}}}, {"uuid": "533f6e2a-609f-4f35-b833-e72a97fa7768", "name": "", "x": 38.669563658980074, "y": -122.47284200415966, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e189aaf-7650-49b4-83dd-94a29111aca2", "name": "p1rdt418lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "533f6e2a-609f-4f35-b833-e72a97fa7768"}}}}, {"uuid": "01cf012e-58c9-48bf-be58-f1427fe77a7e", "name": "", "x": 38.66958917702078, "y": -122.4727989145224, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cdbc11b7-5abf-4ff8-8d26-53faf4b1f3f5", "name": "p1rlv720", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "01cf012e-58c9-48bf-be58-f1427fe77a7e"}}}}, {"uuid": "203182a1-7f0b-4a5e-9a20-44d4dd2260c2", "name": "", "x": 38.67286897139167, "y": -122.46744763392057, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0d9603d6-5e5e-4cc0-aa86-1bdb80f7e1cf", "name": "p1rdt419lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "203182a1-7f0b-4a5e-9a20-44d4dd2260c2"}}}}, {"uuid": "43884182-507e-4cb3-964f-cbc372ccc34f", "name": "", "x": 38.67213944190893, "y": -122.46765283859665, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf12b67c-4df5-4dcb-a2e2-6ae2d0f82e65", "name": "p1rlv721", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "43884182-507e-4cb3-964f-cbc372ccc34f"}}}}, {"uuid": "398a58c5-8907-45e0-9604-09c0300e703e", "name": "", "x": 38.673435838033924, "y": -122.46736734084595, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7551be44-a4ca-4edb-b823-6495d163201e", "name": "p1rlv723", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "398a58c5-8907-45e0-9604-09c0300e703e"}}}}, {"uuid": "8c4e5f78-75c4-4283-98d4-ee2a1e884b43", "name": "", "x": 38.673174243579794, "y": -122.46731180115961, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b2bcbabc-a7fc-4230-8ec1-b6050af9cf58", "name": "p1rlv725", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8c4e5f78-75c4-4283-98d4-ee2a1e884b43"}}}}, {"uuid": "772b3248-d2cb-4f0b-ae16-539c1bc90128", "name": "", "x": 38.67078274236132, "y": -122.4676946740554, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "51673983-9230-421b-8501-bf71601b1b13", "name": "p1rdt420lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "772b3248-d2cb-4f0b-ae16-539c1bc90128"}}}}, {"uuid": "573c2087-0c8d-47da-9307-3efabbf971d7", "name": "", "x": 38.670756762481666, "y": -122.4676520348216, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4b7c6c65-e18c-4e79-b419-8894deb0d345", "name": "p1rlv722", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "573c2087-0c8d-47da-9307-3efabbf971d7"}}}}, {"uuid": "af8bd291-62f7-4b54-ba88-d62e96f0c893", "name": "", "x": 38.70121723278343, "y": -122.42203089954941, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "41f19802-32ca-4afc-8418-fe93e3ced1bb", "name": "p1rdt438lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "af8bd291-62f7-4b54-ba88-d62e96f0c893"}}}}, {"uuid": "b19a4f8f-5cf0-47ea-9609-4688e1df6de3", "name": "", "x": 38.70105000563393, "y": -122.4222662235864, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "80983704-a98f-46dc-a09f-700bd7df1a29", "name": "p1rlv749", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b19a4f8f-5cf0-47ea-9609-4688e1df6de3"}}}}, {"uuid": "4f2f25dd-3d70-420e-968d-3be4cdda8b52", "name": "", "x": 38.70143522055596, "y": -122.42180311856214, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b3c3b0fb-5a5d-439e-a350-b97ba0df41a0", "name": "p1rlv756", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4f2f25dd-3d70-420e-968d-3be4cdda8b52"}}}}, {"uuid": "4c670b17-732d-4dd3-98fc-a09595996303", "name": "", "x": 38.70124602203702, "y": -122.42077844448052, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bc7e7e51-f849-4bf4-b720-462daeb21932", "name": "p1rdt445lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c670b17-732d-4dd3-98fc-a09595996303"}}}}, {"uuid": "4ccd8de8-d3e4-446c-baf4-2b5f353790d1", "name": "", "x": 38.7012715204705, "y": -122.42073531744347, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e368704b-6c4b-4afb-a577-4b0d7a96dd65", "name": "p1rlv764", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ccd8de8-d3e4-446c-baf4-2b5f353790d1"}}}}, {"uuid": "1cc0b3d4-8021-4b32-8abb-e969a4fb62aa", "name": "", "x": 38.7015601074417, "y": -122.42258142494296, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0727e1f5-f2ca-4e19-9dc3-89e185002e52", "name": "p1rdt446lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1cc0b3d4-8021-4b32-8abb-e969a4fb62aa"}}}}, {"uuid": "c900b3f3-baf8-427c-8542-c5f2ffa1355a", "name": "", "x": 38.70157447780686, "y": -122.4226322555927, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "07381934-8e9b-4447-a330-e8af484331f1", "name": "p1rlv766", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c900b3f3-baf8-427c-8542-c5f2ffa1355a"}}}}, {"uuid": "4a885b64-5e1b-46ae-883a-62e3888a8c6a", "name": "", "x": 38.69708395346926, "y": -122.37425747756579, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "44f86829-17fc-4e83-b2a5-705454293161", "name": "p1rdt452lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4a885b64-5e1b-46ae-883a-62e3888a8c6a"}}}}, {"uuid": "918a6e1b-0380-4647-a2bd-aafaaf6b3a88", "name": "", "x": 38.69705554229972, "y": -122.37452973492258, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "180adab2-e49b-42e9-9aeb-42be0a7686c5", "name": "p1rlv786", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "918a6e1b-0380-4647-a2bd-aafaaf6b3a88"}}}}, {"uuid": "8dad0c31-e9b0-4799-b268-7c2874861bb7", "name": "", "x": 38.69721614595881, "y": -122.37422935064228, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b4fed6c4-6907-4601-9671-6f83d582dc45", "name": "p1rdm812", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8dad0c31-e9b0-4799-b268-7c2874861bb7"}}}}, {"uuid": "d3fc1810-0682-44c8-b0c8-c28ddb55de10", "name": "", "x": 38.69725422113334, "y": -122.3746085006707, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d00977fb-8d2a-44ca-aa9e-034894d6e280", "name": "p1rlv775", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d3fc1810-0682-44c8-b0c8-c28ddb55de10"}}}}, {"uuid": "75499f39-83de-43a8-a654-d945fb405baf", "name": "", "x": 38.6969100698522, "y": -122.37428951464027, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "090024f2-1724-4789-96da-174d1f5e65ec", "name": "p1rdm814", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "75499f39-83de-43a8-a654-d945fb405baf"}}}}, {"uuid": "a51d797c-e6f0-4b32-b7b9-c278c8b44c8c", "name": "", "x": 38.69694740684703, "y": -122.37453067672068, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4c5b1f75-47c0-45c3-9ef3-f97a445b242e", "name": "p1rlv776", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a51d797c-e6f0-4b32-b7b9-c278c8b44c8c"}}}}, {"uuid": "fa3c1915-fa2a-4d21-a0f6-6488b0414d01", "name": "", "x": 38.69672717493211, "y": -122.37432163006257, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d58e1471-844f-46ef-9d9a-43753b1dee25", "name": "p1rdt453lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa3c1915-fa2a-4d21-a0f6-6488b0414d01"}}}}, {"uuid": "fea9bebc-eef7-4fe5-b640-a25baff0a50c", "name": "", "x": 38.696649943652076, "y": -122.37428890620298, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ecd0e9ae-cbf4-4435-8a57-ad23e3e037b4", "name": "p1rdm815", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fea9bebc-eef7-4fe5-b640-a25baff0a50c"}}}}, {"uuid": "566e28aa-36fb-42ab-a68d-202b695174ed", "name": "", "x": 38.69663225777152, "y": -122.37457941885675, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "def7e507-cb62-42f5-8451-b8a742ef4eb2", "name": "p1rlv819", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "566e28aa-36fb-42ab-a68d-202b695174ed"}}}}, {"uuid": "7d2179fa-de53-465f-87d5-363053bbc7d5", "name": "", "x": 38.70111870876331, "y": -122.37432184237016, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d2e41779-98fa-453d-b4df-10a5dd61a4b5", "name": "p1rdm816", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7d2179fa-de53-465f-87d5-363053bbc7d5"}}}}, {"uuid": "3eef0e56-9c2d-4b51-ba64-e4b46a209297", "name": "", "x": 38.70112000065753, "y": -122.37456333253593, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6fb1fca8-7985-4356-a8de-7433fef7a454", "name": "p1rlv777", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3eef0e56-9c2d-4b51-ba64-e4b46a209297"}}}}, {"uuid": "253db7aa-5fce-4b55-9ec6-020f592f3b00", "name": "", "x": 38.70157181887224, "y": -122.3742643698461, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0b3e7941-9bdd-48f9-a4a5-a553da9bbb57", "name": "p1rdt454lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "253db7aa-5fce-4b55-9ec6-020f592f3b00"}}}}, {"uuid": "2d928d67-5f6a-413b-ae62-6f67424a1c6d", "name": "", "x": 38.70172394100054, "y": -122.37459257247573, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "87e4ddc3-ccc3-48af-bc35-d7d85f324ee7", "name": "p1rdm817", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2d928d67-5f6a-413b-ae62-6f67424a1c6d"}}}}, {"uuid": "b22926f4-6b7d-47e3-ae23-fadd82a8b5ac", "name": "", "x": 38.701795539168316, "y": -122.37449994744384, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e9ce2439-fcc7-4965-81ee-f875db83b003", "name": "p1rlv789", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b22926f4-6b7d-47e3-ae23-fadd82a8b5ac"}}}}, {"uuid": "66477536-d6bd-43e1-8c9e-745b5321f80e", "name": "", "x": 38.7013420827754, "y": -122.37396339276478, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bf188897-9db5-4ff4-8c5b-5932a8a794cf", "name": "p1rdm818", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "66477536-d6bd-43e1-8c9e-745b5321f80e"}}}}, {"uuid": "23378020-dbad-4f0d-b057-ffe4e0117567", "name": "", "x": 38.70145818262173, "y": -122.37376687845641, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3126c61-9602-45cf-8d57-27d26c14ca7e", "name": "p1rlv800", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "23378020-dbad-4f0d-b057-ffe4e0117567"}}}}, {"uuid": "846a1025-c69e-451f-9377-15537603c6e1", "name": "", "x": 38.70201519147799, "y": -122.37513054558815, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b757a90a-ade8-486f-90f1-e7c5e13708ba", "name": "p1rdm819", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "846a1025-c69e-451f-9377-15537603c6e1"}}}}, {"uuid": "fc9c2527-9baf-4404-96ae-ee464d18a789", "name": "", "x": 38.70182669191501, "y": -122.37527018819917, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "80d58665-ee8a-4f4e-a906-dc15aa3d8c6f", "name": "p1rlv778", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fc9c2527-9baf-4404-96ae-ee464d18a789"}}}}, {"uuid": "ce8a26f6-92ff-436e-bfa0-57e400e499d7", "name": "", "x": 38.7019178147915, "y": -122.37492836596363, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "53b40b3c-db5a-4fa0-bedb-f293c6eac473", "name": "p1rdt455lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ce8a26f6-92ff-436e-bfa0-57e400e499d7"}}}}, {"uuid": "87337660-1d35-46ef-9aa5-4733c6572e85", "name": "", "x": 38.70180590348404, "y": -122.37475286106623, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ea28f170-6bf0-47f7-a089-8375dff2ad4a", "name": "p1rdm820", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "87337660-1d35-46ef-9aa5-4733c6572e85"}}}}, {"uuid": "43ef4919-06d3-41a8-a235-9fbe88ea5687", "name": "", "x": 38.701671533532036, "y": -122.37490353316474, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d0089ee3-0cb4-434c-adc4-c91a8441ef0a", "name": "p1rlv787", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "43ef4919-06d3-41a8-a235-9fbe88ea5687"}}}}, {"uuid": "29077723-8ec8-453b-8c57-cdfce7b38831", "name": "", "x": 38.70149204551021, "y": -122.37504309725601, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "052949b1-9e85-4be7-993c-9e97efda3657", "name": "p1rlv811", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "29077723-8ec8-453b-8c57-cdfce7b38831"}}}}, {"uuid": "2c30f199-abfe-4d48-b1ca-b49cf7589e41", "name": "", "x": 38.69874038147765, "y": -122.37499407083057, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6abe982-a205-4607-bacf-08e9d7cb6f54", "name": "p1rdt456lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2c30f199-abfe-4d48-b1ca-b49cf7589e41"}}}}, {"uuid": "dd0efdae-a64f-41af-ba64-43b865c65806", "name": "", "x": 38.6988698234033, "y": -122.37507741848081, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33492e0f-c907-46c6-a529-503480b642bb", "name": "p1rlv837", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dd0efdae-a64f-41af-ba64-43b865c65806"}}}}, {"uuid": "0199de53-9365-434d-aa43-d2c1589ff2db", "name": "", "x": 38.69908332769086, "y": -122.37455807209501, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e3cae47a-4077-44e6-9761-fc30d85c3442", "name": "p1rdm822", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0199de53-9365-434d-aa43-d2c1589ff2db"}}}}, {"uuid": "e7862db2-6252-4c87-8f40-cc4b08525a6b", "name": "", "x": 38.699192938897575, "y": -122.3748331116339, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fbc761bf-480c-465c-9479-279832c50bc2", "name": "p1rlv779", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e7862db2-6252-4c87-8f40-cc4b08525a6b"}}}}, {"uuid": "fde861ab-384e-4d57-9c4b-8d29c452a1a4", "name": "", "x": 38.69872582718306, "y": -122.37511317064184, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "84ca6719-0bbc-440a-b0eb-23b8f32dcf47", "name": "p1rdm823", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fde861ab-384e-4d57-9c4b-8d29c452a1a4"}}}}, {"uuid": "a276efc9-12d7-4647-8126-ba4bf608023b", "name": "", "x": 38.69852447935862, "y": -122.37506494784137, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be4b6c4e-78d0-4c8e-907c-619f1e43c149", "name": "p1rlv831", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a276efc9-12d7-4647-8126-ba4bf608023b"}}}}, {"uuid": "dc7c9480-fff2-4481-9abb-71107106b522", "name": "", "x": 38.69449656825178, "y": -122.37575189359077, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "866745cc-62c9-429f-8389-fcc5a1710f17", "name": "p1rdt457lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dc7c9480-fff2-4481-9abb-71107106b522"}}}}, {"uuid": "fa6c14d6-12bd-4418-bb7c-5b75aabf228d", "name": "", "x": 38.69441132364952, "y": -122.37550717957821, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "20dcf67f-f04f-498a-830d-557ba7b4d867", "name": "p1rlv780", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa6c14d6-12bd-4418-bb7c-5b75aabf228d"}}}}, {"uuid": "845013de-0fa5-4507-86c0-0171eb46dab6", "name": "", "x": 38.694628638419935, "y": -122.3757007735009, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bf7e29df-0880-4c8c-aa5c-c43f24dd820e", "name": "p1rdm826", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "845013de-0fa5-4507-86c0-0171eb46dab6"}}}}, {"uuid": "4c292e42-91c1-425c-ab9d-78892c7e4836", "name": "", "x": 38.694609633506126, "y": -122.37551695428785, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2d1a96d5-f971-4116-9642-769ef5b97e7c", "name": "p1rlv783", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c292e42-91c1-425c-ab9d-78892c7e4836"}}}}, {"uuid": "be8d4ef3-4f9e-4921-94e3-a481ca49b2ff", "name": "", "x": 38.69466560426392, "y": -122.3758729377002, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eb137176-0642-4d87-ae40-1b7b0e1cb214", "name": "p1rlv795", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be8d4ef3-4f9e-4921-94e3-a481ca49b2ff"}}}}, {"uuid": "1a861ef0-a169-461f-abde-6f601141ce10", "name": "", "x": 38.694926011094644, "y": -122.37569818860291, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8fafab6a-7d1c-4b87-94b3-5bc4d09ff95d", "name": "p1rdm827", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1a861ef0-a169-461f-abde-6f601141ce10"}}}}, {"uuid": "01722373-7ba3-4bf0-a6df-8a4d2d2d63d4", "name": "", "x": 38.69489143888521, "y": -122.37597446682435, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3fe9bb3f-e3c1-4b59-b39f-f62271a55bdd", "name": "p1rlv791", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "01722373-7ba3-4bf0-a6df-8a4d2d2d63d4"}}}}, {"uuid": "9fc67f87-3522-4d69-a9a3-b9248ad5e601", "name": "", "x": 38.694187760198, "y": -122.37583109428404, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dc2d45e2-caa5-4f7d-976e-ccb045c30559", "name": "p1rdm829", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9fc67f87-3522-4d69-a9a3-b9248ad5e601"}}}}, {"uuid": "719b05d2-eba8-4118-9171-d1406b60336f", "name": "", "x": 38.694161769492204, "y": -122.3760268023747, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1ecc45b2-1fbe-4a31-995f-e2f8fffe61a7", "name": "p1rlv801", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "719b05d2-eba8-4118-9171-d1406b60336f"}}}}, {"uuid": "b6e99fb2-ec36-4ae6-9455-b941776f70f0", "name": "", "x": 38.69415358661105, "y": -122.37565138406234, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "11064c6f-3b7a-43b5-96ca-7ef96be3815e", "name": "p1rlv817", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b6e99fb2-ec36-4ae6-9455-b941776f70f0"}}}}, {"uuid": "f55d31ca-bc69-454e-8549-05d666f255d3", "name": "", "x": 38.695030276964474, "y": -122.37497283941411, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c668ab72-249e-4463-a3b4-863c7fe826c1", "name": "p1rdm831", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f55d31ca-bc69-454e-8549-05d666f255d3"}}}}, {"uuid": "ba483e47-e191-4d8f-aa43-0cdc306972f9", "name": "", "x": 38.69496811967224, "y": -122.37514586658888, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "98c5ba15-a339-478a-a79f-9298fab16a54", "name": "p1rlv781", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ba483e47-e191-4d8f-aa43-0cdc306972f9"}}}}, {"uuid": "b26f7ad4-878d-4d83-a117-65a1974f593c", "name": "", "x": 38.69490966180515, "y": -122.37485492226794, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "67e071ab-e3dc-4779-9e81-585547cd22ca", "name": "p1rdt458lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b26f7ad4-878d-4d83-a117-65a1974f593c"}}}}, {"uuid": "1c4ced69-d921-431e-a0ed-4f7bda33c6ce", "name": "", "x": 38.69482154193585, "y": -122.37469867853063, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "92f03cbf-2585-4e0e-ab0a-cda0b267b34d", "name": "p1rdm832", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1c4ced69-d921-431e-a0ed-4f7bda33c6ce"}}}}, {"uuid": "1da019c9-03b8-4947-aabc-fe8b39b50d8d", "name": "", "x": 38.69478038429, "y": -122.37489849683361, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c3bc013f-c78d-4a3c-b27f-826c3025de0e", "name": "p1rlv843", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1da019c9-03b8-4947-aabc-fe8b39b50d8d"}}}}, {"uuid": "379cb4d3-78c7-4221-af0f-e1a5b188a4bb", "name": "", "x": 38.701681041918285, "y": -122.37384145943425, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9eb57d99-ae80-43da-b0cb-b26bdd583e1a", "name": "p1rdt459lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "379cb4d3-78c7-4221-af0f-e1a5b188a4bb"}}}}, {"uuid": "e4637786-72a5-4382-96af-a9d4bb9b3ddd", "name": "", "x": 38.7019010899339, "y": -122.37401601985513, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "78a4f54a-017a-41b0-85c8-b3e408c21c08", "name": "p1rlv782", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e4637786-72a5-4382-96af-a9d4bb9b3ddd"}}}}, {"uuid": "77846b24-5292-42be-bdfc-2dd8cb5fe3f7", "name": "", "x": 38.70217626105635, "y": -122.37544717401559, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "028bc055-0ee6-4729-8cd2-15bd7153f975", "name": "p1rdt460lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "77846b24-5292-42be-bdfc-2dd8cb5fe3f7"}}}}, {"uuid": "b26c164b-bd1d-4e3b-b693-7687b88241a5", "name": "", "x": 38.70212578404628, "y": -122.37558959231082, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2823b5b9-bcc3-4b30-9874-89dc33ec80d2", "name": "p1rlv784", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b26c164b-bd1d-4e3b-b693-7687b88241a5"}}}}, {"uuid": "10c6883a-43b8-4c15-b651-d1ef7659c9b6", "name": "", "x": 38.702286881592116, "y": -122.37538118676348, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9b1c34f1-2613-46aa-9a9f-686ee518e559", "name": "p1rlv797", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10c6883a-43b8-4c15-b651-d1ef7659c9b6"}}}}, {"uuid": "b4b4ec33-db46-469e-a833-d5e498acc9ff", "name": "", "x": 38.702257020866284, "y": -122.37485243501904, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "790d0b88-fed2-4c90-bfdf-44d3c31d3d8d", "name": "p1rdm837", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b4b4ec33-db46-469e-a833-d5e498acc9ff"}}}}, {"uuid": "8295e92c-cbac-4f52-982a-bf37131d64d8", "name": "", "x": 38.70215746639765, "y": -122.37477280015747, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0d9f269a-e476-4b82-a258-479d812d008d", "name": "p1rlv806", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8295e92c-cbac-4f52-982a-bf37131d64d8"}}}}, {"uuid": "b98023ea-f8a2-432c-81a7-f05c1eec5f47", "name": "", "x": 38.702419502723, "y": -122.37467564114138, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e0e1d710-2ab1-43ca-a7c1-8f05a6c0b753", "name": "p1rdm835", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b98023ea-f8a2-432c-81a7-f05c1eec5f47"}}}}, {"uuid": "3396a052-4e10-4614-970a-e52b38290a46", "name": "", "x": 38.702500140978806, "y": -122.37481581739344, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "59662cef-c126-4188-ad86-844f6cabaf34", "name": "p1rlv796", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3396a052-4e10-4614-970a-e52b38290a46"}}}}, {"uuid": "e7917d2d-5f0a-4c8d-8ea2-3fd31c3312ae", "name": "", "x": 38.702324093645906, "y": -122.3755993680085, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "83fdcccd-6a26-4311-aad3-da67dac5af42", "name": "p1rdm838", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e7917d2d-5f0a-4c8d-8ea2-3fd31c3312ae"}}}}, {"uuid": "076990c7-d743-4fbb-89e1-5ebc4b093ce1", "name": "", "x": 38.70238649707223, "y": -122.37547232235222, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fb4a881f-684d-48e4-a6f0-5832f73d140a", "name": "p1rlv810", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "076990c7-d743-4fbb-89e1-5ebc4b093ce1"}}}}, {"uuid": "46076791-3910-4848-af07-6360ab1902cb", "name": "", "x": 38.70245104977729, "y": -122.37574776762911, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "344c24ef-9d54-4c1a-9aa4-852a76ddbec7", "name": "p1rdm839", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "46076791-3910-4848-af07-6360ab1902cb"}}}}, {"uuid": "364fe691-43cc-4586-8fbb-f3eed45bd625", "name": "", "x": 38.702223773417444, "y": -122.37590677054554, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d7ce197c-cee4-40df-b1d7-be13f1be8bb1", "name": "p1rlv822", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "364fe691-43cc-4586-8fbb-f3eed45bd625"}}}}, {"uuid": "69fe6bcf-63e7-4326-8de4-0eb763d1cef8", "name": "", "x": 38.70257800572197, "y": -122.37589616777406, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f0649432-ddb6-4648-8efe-27ee1fd959e4", "name": "p1rdm840", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "69fe6bcf-63e7-4326-8de4-0eb763d1cef8"}}}}, {"uuid": "e3ed841d-238a-473c-a6d8-4520609914f3", "name": "", "x": 38.70249776336369, "y": -122.37605786929961, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48e97be9-1f80-457f-a56e-79f54458c620", "name": "p1rlv839", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e3ed841d-238a-473c-a6d8-4520609914f3"}}}}, {"uuid": "fb47db4c-2eb8-46db-9d85-36ca6f7eac85", "name": "", "x": 38.69757588310151, "y": -122.37577864853107, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "505b390e-ffd3-482a-8ae9-b8d6bd8be94f", "name": "p1rdm841", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fb47db4c-2eb8-46db-9d85-36ca6f7eac85"}}}}, {"uuid": "7a77042f-fabf-48ca-b7bc-e10792c76c69", "name": "", "x": 38.69764123251456, "y": -122.37620356241798, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fa98d6c6-7086-4033-a9af-c0a33e802942", "name": "p1rlv785", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7a77042f-fabf-48ca-b7bc-e10792c76c69"}}}}, {"uuid": "f5f55bde-5e43-4018-86ad-8b885d9136a3", "name": "", "x": 38.697416472212836, "y": -122.37577251090494, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fd9a4931-435b-4b48-907c-024c0b8a4816", "name": "p1rdt461lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5f55bde-5e43-4018-86ad-8b885d9136a3"}}}}, {"uuid": "ebe1a657-73a9-459f-b0e0-fec2ca16456a", "name": "", "x": 38.69704403287731, "y": -122.37574877318404, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "172dd9d0-eab4-4481-9edd-f868e6ed87d9", "name": "p1rdm842", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ebe1a657-73a9-459f-b0e0-fec2ca16456a"}}}}, {"uuid": "3ccc8255-f565-4d1d-a03a-3ea1fc03d740", "name": "", "x": 38.69698334699525, "y": -122.37619777752667, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0e8c4bc9-0688-43e6-93a8-9664c9b618b7", "name": "p1rlv793", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3ccc8255-f565-4d1d-a03a-3ea1fc03d740"}}}}, {"uuid": "c0565ae7-3fec-4631-b6f3-a84c739859a2", "name": "", "x": 38.702201293623176, "y": -122.37338841314656, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d96f458-607c-4820-90b1-6fb2625ace7f", "name": "p1rdt462lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c0565ae7-3fec-4631-b6f3-a84c739859a2"}}}}, {"uuid": "117ffc96-232e-4015-aac7-6296e312ddff", "name": "", "x": 38.70221229583861, "y": -122.37323129022502, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bf42fa7f-370e-400e-8f6d-76eb8c70ecb9", "name": "p1rlv790", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "117ffc96-232e-4015-aac7-6296e312ddff"}}}}, {"uuid": "66ee1141-41be-44d4-b986-8ebb97d5a851", "name": "", "x": 38.702384188075854, "y": -122.3733562927121, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3ac64728-e64c-4241-8a3f-b884f11c6393", "name": "p1rdm843", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "66ee1141-41be-44d4-b986-8ebb97d5a851"}}}}, {"uuid": "860e4eab-613f-40e5-be26-b497bf4248c4", "name": "", "x": 38.70231135824942, "y": -122.37321892523424, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c9f470d9-6ead-4413-ad8a-7ccc69ae9237", "name": "p1rlv788", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "860e4eab-613f-40e5-be26-b497bf4248c4"}}}}, {"uuid": "dd8c6bac-9564-42dc-9c64-f3f6da327a3c", "name": "", "x": 38.7025463910665, "y": -122.37335487708582, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2086cded-e13c-4683-824e-9e15f99e12e8", "name": "p1rdm846", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dd8c6bac-9564-42dc-9c64-f3f6da327a3c"}}}}, {"uuid": "4c0f531e-29cb-4717-b893-ab2bbcda29c3", "name": "", "x": 38.70252953923245, "y": -122.37357352972886, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6e2a8871-7bc4-497f-9954-38db92cb3eba", "name": "p1rlv864", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c0f531e-29cb-4717-b893-ab2bbcda29c3"}}}}, {"uuid": "c59df0b4-eab3-43e2-9baa-fb2da89819cf", "name": "", "x": 38.702105331447335, "y": -122.37345072820672, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b4620a0-c781-422e-8cc7-3ceed9a0c8dc", "name": "p1rdm845", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c59df0b4-eab3-43e2-9baa-fb2da89819cf"}}}}, {"uuid": "f1970de7-55c0-4d65-a1ad-1d38a4180337", "name": "", "x": 38.70188944897217, "y": -122.37299658085036, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "024961c3-25f4-4a15-a52a-7f88dc652766", "name": "p1rlv840", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f1970de7-55c0-4d65-a1ad-1d38a4180337"}}}}, {"uuid": "c6c1d19e-c4b9-419a-a813-bc297120bd26", "name": "", "x": 38.702162992217495, "y": -122.3735922043492, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "abdfa5db-c398-4638-805d-6d55597e1921", "name": "p1rlv865", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c6c1d19e-c4b9-419a-a813-bc297120bd26"}}}}, {"uuid": "b294bc07-25bb-471e-adef-295df19ea6ae", "name": "", "x": 38.702251051988306, "y": -122.37373696284877, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1a7cca48-fd4b-4630-a479-55f2b6ada03b", "name": "p1rlv867", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b294bc07-25bb-471e-adef-295df19ea6ae"}}}}, {"uuid": "4ee440dd-1144-418b-b9e5-686ac95fe047", "name": "", "x": 38.70003035932669, "y": -122.37586478778037, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f660c35e-85f8-4f0e-b03b-806006c76c67", "name": "p1rdt463lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ee440dd-1144-418b-b9e5-686ac95fe047"}}}}, {"uuid": "6c8c6605-54a0-4f74-a558-cea62a6e6755", "name": "", "x": 38.7000284875326, "y": -122.37604482598387, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f806232e-0a52-46d5-80f7-7ea3a914137a", "name": "p1rlv792", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c8c6605-54a0-4f74-a558-cea62a6e6755"}}}}, {"uuid": "a1a9621f-11fc-426f-87dd-3d67019f0b3b", "name": "", "x": 38.699938225668625, "y": -122.37578973798107, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c397a5a5-21bc-4f4d-9f24-7af1219b70e7", "name": "p1rdm850", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a1a9621f-11fc-426f-87dd-3d67019f0b3b"}}}}, {"uuid": "28e708f2-3c1d-404d-8dcb-ecb29b51303c", "name": "", "x": 38.69980443234621, "y": -122.37627677000896, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bada1117-5605-4aec-9314-8013ed243e3c", "name": "p1rlv860", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "28e708f2-3c1d-404d-8dcb-ecb29b51303c"}}}}, {"uuid": "21cd6750-0958-4f0b-9fd8-b9f9372c0348", "name": "", "x": 38.69546877867281, "y": -122.373869079739, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "749e07aa-74ce-40f2-a352-9c55f9914377", "name": "p1rdt464lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "21cd6750-0958-4f0b-9fd8-b9f9372c0348"}}}}, {"uuid": "65f83ebc-aea0-429a-a6b4-dc69a6e34403", "name": "", "x": 38.6953493322175, "y": -122.37396963727394, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4eecc456-41af-4242-ab30-d8ca45d55a2c", "name": "p1rlv794", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65f83ebc-aea0-429a-a6b4-dc69a6e34403"}}}}, {"uuid": "efde92d7-4f87-4aa8-833a-398f86a5bcd0", "name": "", "x": 38.69564655774635, "y": -122.37393116894758, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "17b42dae-f856-4945-ba7a-9d3f47e049fe", "name": "p1rdm852", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "efde92d7-4f87-4aa8-833a-398f86a5bcd0"}}}}, {"uuid": "ede6db0e-440b-4e2d-8435-9539c4f9fe4c", "name": "", "x": 38.69550381660122, "y": -122.37420977320264, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d209dff6-7a24-41ef-947a-8c6f79c2d65c", "name": "p1rlv825", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ede6db0e-440b-4e2d-8435-9539c4f9fe4c"}}}}, {"uuid": "6c196105-5de5-4ebf-8534-5b9673501c2d", "name": "", "x": 38.69529421784077, "y": -122.37377463240384, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "08c93f8a-9600-4ffd-8e18-576d433ce777", "name": "p1rdm853", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c196105-5de5-4ebf-8534-5b9673501c2d"}}}}, {"uuid": "00f12ce4-6279-4f7f-b351-ef6b4d9d1895", "name": "", "x": 38.6954016143038, "y": -122.37363570614771, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8e3a1bd0-69fe-42bb-993d-2094ecc658ce", "name": "p1rlv829", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "00f12ce4-6279-4f7f-b351-ef6b4d9d1895"}}}}, {"uuid": "a12d289b-3eb4-436f-9fcb-4e06e31acedf", "name": "", "x": 38.6980078724581, "y": -122.37567139741331, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d5ad091a-3b6a-4069-a642-104c28a94dc4", "name": "p1rdm855", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a12d289b-3eb4-436f-9fcb-4e06e31acedf"}}}}, {"uuid": "e1b7c1d6-d5c9-416e-b644-68ca8ac89c67", "name": "", "x": 38.69804305798535, "y": -122.3755100974583, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e0f8ee8-795f-4bea-bf7a-e2c477eefb89", "name": "p1rlv809", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e1b7c1d6-d5c9-416e-b644-68ca8ac89c67"}}}}, {"uuid": "5f783c36-4d6c-46a7-a596-a1775597daf0", "name": "", "x": 38.69840981645937, "y": -122.37572585292882, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "433b0872-49c4-452c-941c-8083a72840ce", "name": "p1rdt465lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5f783c36-4d6c-46a7-a596-a1775597daf0"}}}}, {"uuid": "e28eaec9-f284-4eaf-8033-7359f6a39638", "name": "", "x": 38.69867415513827, "y": -122.37556210766509, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eaf112db-b9dc-4d90-b030-3e26188aaf2b", "name": "p1rdm856", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e28eaec9-f284-4eaf-8033-7359f6a39638"}}}}, {"uuid": "6f275d6c-b659-4a8f-9701-15a2f8ced9bc", "name": "", "x": 38.69855682418657, "y": -122.37552862894972, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d5e2c3a2-32c0-4bb9-9802-265cec784974", "name": "p1rlv862", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6f275d6c-b659-4a8f-9701-15a2f8ced9bc"}}}}, {"uuid": "13e20615-a6e4-4635-9781-ad96b92e29cd", "name": "", "x": 38.6988553632223, "y": -122.37574452723823, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eb73d9f2-aefb-430c-babd-ac02422eb212", "name": "p1rdm854", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "13e20615-a6e4-4635-9781-ad96b92e29cd"}}}}, {"uuid": "b48c379e-4147-4789-8a0b-4f78bd953f0b", "name": "", "x": 38.69885849252648, "y": -122.3763309850566, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c30005d7-7e42-4a08-8935-0c7227fba4a6", "name": "p1rlv798", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b48c379e-4147-4789-8a0b-4f78bd953f0b"}}}}, {"uuid": "b9e5cf5a-e99c-413d-b8a9-d68c8495cc17", "name": "", "x": 38.697834262777405, "y": -122.37522442460597, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c274aa99-a566-4915-83af-7115bec586b1", "name": "p1rdm857", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b9e5cf5a-e99c-413d-b8a9-d68c8495cc17"}}}}, {"uuid": "d06026e0-9130-4360-96b9-adbed16f39bd", "name": "", "x": 38.69763601444608, "y": -122.37522614936233, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6f706d9d-0cb1-453b-9ca5-377f7d766099", "name": "p1rlv799", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d06026e0-9130-4360-96b9-adbed16f39bd"}}}}, {"uuid": "d3d04da5-e3f9-4ba5-96af-05e7b20a1b7b", "name": "", "x": 38.69792563161655, "y": -122.37492861747332, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f422478c-0d77-48c8-87fb-e883d945f8a6", "name": "p1rdt466lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d3d04da5-e3f9-4ba5-96af-05e7b20a1b7b"}}}}, {"uuid": "6a7949b0-112b-4610-a8e8-2178e83b8af6", "name": "", "x": 38.69756758613625, "y": -122.37422628827595, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "caa7d639-522c-4fd6-8b74-73a337bd67d2", "name": "p1rdm858", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a7949b0-112b-4610-a8e8-2178e83b8af6"}}}}, {"uuid": "be08b287-4bce-4f87-b15e-4e011958954e", "name": "", "x": 38.69752942558697, "y": -122.37436063848634, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7a134556-828b-4e0c-8773-2f207802e33a", "name": "p1rlv815", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be08b287-4bce-4f87-b15e-4e011958954e"}}}}, {"uuid": "11ac6b38-60a5-49b9-8a0a-540db3fefb3c", "name": "", "x": 38.694252540223, "y": -122.37330828127818, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "23ed76af-dcb2-4333-ae4c-d7439a37cf87", "name": "p1rdt467lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "11ac6b38-60a5-49b9-8a0a-540db3fefb3c"}}}}, {"uuid": "d1963ecf-1914-499a-8472-b5247aebbf28", "name": "", "x": 38.69427815650523, "y": -122.37304358141793, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b2436086-d5c4-4b70-a402-e7d1b6f5b77e", "name": "p1rlv802", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1963ecf-1914-499a-8472-b5247aebbf28"}}}}, {"uuid": "3be967c7-0670-4f96-b81c-c29550a7414c", "name": "", "x": 38.695512481684965, "y": -122.37583108066667, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3a4bf0e0-92f0-4cd9-afc5-65d9ed242271", "name": "p1rdm861", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3be967c7-0670-4f96-b81c-c29550a7414c"}}}}, {"uuid": "efeb21c5-4624-459c-9e98-5cc05610708d", "name": "", "x": 38.69558659678035, "y": -122.3762099095591, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "81802469-7320-47e9-b826-fbb33bd371ab", "name": "p1rlv823", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "efeb21c5-4624-459c-9e98-5cc05610708d"}}}}, {"uuid": "033a2a11-14fb-4987-9143-4c5ea81d6861", "name": "", "x": 38.695386323591904, "y": -122.37583217708425, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3bfca289-c04c-45d9-8104-40089fc1737e", "name": "p1rdm860", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "033a2a11-14fb-4987-9143-4c5ea81d6861"}}}}, {"uuid": "a8f165ab-776e-40e3-8147-22b245234707", "name": "", "x": 38.6953513829787, "y": -122.3760394653489, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "018c978c-5673-4090-9792-b75ee161f6d2", "name": "p1rlv803", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8f165ab-776e-40e3-8147-22b245234707"}}}}, {"uuid": "a29fd963-e063-4256-9052-473ca445a911", "name": "", "x": 38.69564629017529, "y": -122.3756964667581, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b368fb8f-7f4d-4558-b6b2-2e1db4087727", "name": "p1rdt468lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a29fd963-e063-4256-9052-473ca445a911"}}}}, {"uuid": "f35e8328-37b1-44a2-a763-afa113575634", "name": "", "x": 38.696223821296954, "y": -122.37572140485321, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1daf402d-faec-4230-b4ab-1efa6283ac0f", "name": "p1rdm862", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f35e8328-37b1-44a2-a763-afa113575634"}}}}, {"uuid": "0c90b1a8-53a5-4b65-b599-aa1c94439206", "name": "", "x": 38.696252021310734, "y": -122.37593964620868, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2eb57fc4-636d-4923-9f4a-d308b062599f", "name": "p1rlv833", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0c90b1a8-53a5-4b65-b599-aa1c94439206"}}}}, {"uuid": "4c5c36ba-98c8-4540-bd20-b43167f47a63", "name": "", "x": 38.69464965312743, "y": -122.37341980651155, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d12ab15f-746d-462b-b395-e2b330ba1226", "name": "p1rdt469lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c5c36ba-98c8-4540-bd20-b43167f47a63"}}}}, {"uuid": "a5345d32-563a-4acd-b251-ba5e631ee422", "name": "", "x": 38.6946876894052, "y": -122.37326246422553, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0475b34e-14ab-48e4-9df7-7444de1cde7d", "name": "p1rlv805", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a5345d32-563a-4acd-b251-ba5e631ee422"}}}}, {"uuid": "087c125b-3c1d-4629-a9c6-0573dbf2e0c5", "name": "", "x": 38.70251978737086, "y": -122.37458961698891, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "15ab2647-a801-4cb5-a1f7-528118ff5dea", "name": "p1rdt470lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "087c125b-3c1d-4629-a9c6-0573dbf2e0c5"}}}}, {"uuid": "689170c1-88d4-43af-91c5-010c0ce51404", "name": "", "x": 38.70270494012969, "y": -122.37435402129528, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ab33ce2f-3131-4cfb-8df2-329fb4aa76b7", "name": "p1rlv858", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "689170c1-88d4-43af-91c5-010c0ce51404"}}}}, {"uuid": "f578b711-1e16-41bc-aea1-727982d2a44c", "name": "", "x": 38.70236818204675, "y": -122.3747179490724, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d861761c-3fe7-437d-917d-8beb24318a42", "name": "p1rdm864", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f578b711-1e16-41bc-aea1-727982d2a44c"}}}}, {"uuid": "186932a4-38ef-4136-bf3f-59f1cf536dfd", "name": "", "x": 38.702215723425525, "y": -122.37440030860232, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aa259be8-8a61-461a-9e58-d4aaf1ce82db", "name": "p1rlv807", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "186932a4-38ef-4136-bf3f-59f1cf536dfd"}}}}, {"uuid": "0a7684b2-4e2a-4be3-aaf0-80e9592fb790", "name": "", "x": 38.701111976317726, "y": -122.37359342043746, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "40d98c0b-4c66-4581-9553-f5f57c4b27b9", "name": "p1rdt471lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a7684b2-4e2a-4be3-aaf0-80e9592fb790"}}}}, {"uuid": "85ea6224-1682-4dce-aec8-40cb358842c6", "name": "", "x": 38.7012040803456, "y": -122.37343559224011, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "06746d4d-3db8-45b1-888e-d3d9e405ccaf", "name": "p1rlv826", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "85ea6224-1682-4dce-aec8-40cb358842c6"}}}}, {"uuid": "50db1ac5-4754-41e4-9d37-bda897dc343b", "name": "", "x": 38.701232962213865, "y": -122.37378034278039, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "467753c6-5c1f-4a9d-8a7d-21419b25565f", "name": "p1rdm866", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "50db1ac5-4754-41e4-9d37-bda897dc343b"}}}}, {"uuid": "dedcff52-3cd3-467f-9c45-71a2c3e1ba7b", "name": "", "x": 38.70131313984175, "y": -122.37360714205926, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9dcb86a4-e6d7-48b4-b5c2-904635de271b", "name": "p1rlv808", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dedcff52-3cd3-467f-9c45-71a2c3e1ba7b"}}}}, {"uuid": "38d6ab03-3e7f-4fd9-883e-cfa2538e6a9f", "name": "", "x": 38.69441071978218, "y": -122.3742383194926, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f026a1d3-23b0-4454-a09b-e1c08cc06392", "name": "p1rdt472lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "38d6ab03-3e7f-4fd9-883e-cfa2538e6a9f"}}}}, {"uuid": "13e8ba29-89b7-4d05-a57a-3f34b24cc43e", "name": "", "x": 38.69453022804182, "y": -122.37414926221291, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6b4834dc-6bdf-4102-bc13-589392b2e75a", "name": "p1rlv866", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "13e8ba29-89b7-4d05-a57a-3f34b24cc43e"}}}}, {"uuid": "f2a7e3eb-ae43-49d8-b76c-8971895da950", "name": "", "x": 38.69435012529591, "y": -122.37417382958121, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f0ca3ea5-ad01-4e52-883a-c07805f613dd", "name": "p1rdm868", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f2a7e3eb-ae43-49d8-b76c-8971895da950"}}}}, {"uuid": "2576f1fb-b6fb-4af7-8366-e83fc7c59d2f", "name": "", "x": 38.69438573967901, "y": -122.37409302632886, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "26fea867-af5f-4213-b9c3-487975d1285e", "name": "p1rlv812", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2576f1fb-b6fb-4af7-8366-e83fc7c59d2f"}}}}, {"uuid": "7cbb35e7-df97-4165-aed4-3095857f8894", "name": "", "x": 38.69659862303915, "y": -122.37433121095306, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0aa0c31f-baa3-4db8-87d9-0a4ab9a83a8a", "name": "p1rdm870", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7cbb35e7-df97-4165-aed4-3095857f8894"}}}}, {"uuid": "c2ef7e3c-d290-41bb-8503-30c839028bfd", "name": "", "x": 38.69661091258349, "y": -122.37395864008647, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "10d44b60-55c0-4d78-abbb-52c8cd67134b", "name": "p1rlv813", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c2ef7e3c-d290-41bb-8503-30c839028bfd"}}}}, {"uuid": "a0e9fbf2-0b6f-4d7f-8873-daa40e499cae", "name": "", "x": 38.696471493549275, "y": -122.3743203106189, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1f435ec5-8c03-45ba-925b-83bad9501047", "name": "p1rdt473lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a0e9fbf2-0b6f-4d7f-8873-daa40e499cae"}}}}, {"uuid": "a099f1a8-ca54-48a4-85f5-70fbea769a79", "name": "", "x": 38.69629742532447, "y": -122.37431785096992, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "67c560cc-d815-41d4-8087-b66beaacb404", "name": "p1rdm871", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a099f1a8-ca54-48a4-85f5-70fbea769a79"}}}}, {"uuid": "d682dfc2-070f-47a5-a193-156d255f04d9", "name": "", "x": 38.6963229822717, "y": -122.37404164512883, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dd8c54fd-14d4-46fa-8bef-59c1097d5026", "name": "p1rlv818", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d682dfc2-070f-47a5-a193-156d255f04d9"}}}}, {"uuid": "d100526f-6d59-48eb-8c30-a2e68b037935", "name": "", "x": 38.695202937157, "y": -122.37577229914999, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "839858f4-3b18-40c3-86f3-e27225e6aba4", "name": "p1rdt474lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d100526f-6d59-48eb-8c30-a2e68b037935"}}}}, {"uuid": "cc9ae46b-eb99-4a30-b30b-6b6e84f4c59e", "name": "", "x": 38.695250110678316, "y": -122.37563787569754, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b8065f3-8286-4f99-aa56-b9b631a2f838", "name": "p1rlv814", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc9ae46b-eb99-4a30-b30b-6b6e84f4c59e"}}}}, {"uuid": "39fb4e3a-9f26-4cfc-9385-c44381ad05b3", "name": "", "x": 38.69519831370313, "y": -122.37606379343438, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1c89db91-40fe-4de6-973e-5d8c23e35080", "name": "p1rlv827", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "39fb4e3a-9f26-4cfc-9385-c44381ad05b3"}}}}, {"uuid": "9c3d2d3a-8524-4e4a-a0b2-c952bd788674", "name": "", "x": 38.69669246979562, "y": -122.37572883039154, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0ec705b7-fdaa-4eca-96eb-5dabb8256c78", "name": "p1rdm874", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9c3d2d3a-8524-4e4a-a0b2-c952bd788674"}}}}, {"uuid": "9eb67d1a-af44-45e3-8bdb-c4ad6a6e4c48", "name": "", "x": 38.696700867165035, "y": -122.37561376379026, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0d6de7c2-fd2c-4071-8e90-1513f521cf87", "name": "p1rlv816", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9eb67d1a-af44-45e3-8bdb-c4ad6a6e4c48"}}}}, {"uuid": "f6f806f4-f6c8-4acc-b5d4-dc9e58c721ea", "name": "", "x": 38.69688462197356, "y": -122.37574263565365, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1be3e20a-3890-4e9c-b568-ca99421e751c", "name": "p1rdt475lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f6f806f4-f6c8-4acc-b5d4-dc9e58c721ea"}}}}, {"uuid": "41f402a8-5a0d-43bb-92ca-31ba1dcfa4df", "name": "", "x": 38.69722432005433, "y": -122.37575870547994, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c17541ac-d30f-4f0a-9660-f9b9f7012b3a", "name": "p1rdm875", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "41f402a8-5a0d-43bb-92ca-31ba1dcfa4df"}}}}, {"uuid": "3d63d01d-b418-490e-98e2-bd17b4c6be29", "name": "", "x": 38.697222293760795, "y": -122.37537924143979, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d437c83c-cbd1-41bf-b455-21123e82d59f", "name": "p1rlv834", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3d63d01d-b418-490e-98e2-bd17b4c6be29"}}}}, {"uuid": "67a0c060-3859-4b1c-be3d-76b775d3991e", "name": "", "x": 38.70013424053621, "y": -122.37444144316905, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2ffde8c6-9dba-4f13-bda5-a0edf17c736d", "name": "p1rdt476lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "67a0c060-3859-4b1c-be3d-76b775d3991e"}}}}, {"uuid": "ced3b102-df6d-43e6-b894-4e4cf7a0fc03", "name": "", "x": 38.700172278057, "y": -122.37428408934844, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "12556ab7-c50a-4624-9d84-b85585822245", "name": "p1rlv836", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ced3b102-df6d-43e6-b894-4e4cf7a0fc03"}}}}, {"uuid": "6a4ba861-04bc-46c0-9877-3f78ef3e6dcc", "name": "", "x": 38.700326331213084, "y": -122.37444374611572, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f83e2ade-1911-4124-9fbe-6f482d68eba9", "name": "p1rdm878", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a4ba861-04bc-46c0-9877-3f78ef3e6dcc"}}}}, {"uuid": "650858b8-9d22-4882-8e53-a5090bc3e20b", "name": "", "x": 38.700363298980754, "y": -122.37461592326322, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e8f304a4-6e39-4288-9b9b-e41bb37c6019", "name": "p1rlv842", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "650858b8-9d22-4882-8e53-a5090bc3e20b"}}}}, {"uuid": "69c25aa2-cce5-47a1-bd11-f511d4e7ef98", "name": "", "x": 38.69999291375323, "y": -122.3744466507155, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "260b560c-e6d6-4069-b67f-067c468a7768", "name": "p1rdm879", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "69c25aa2-cce5-47a1-bd11-f511d4e7ef98"}}}}, {"uuid": "0b280d8d-3c4c-40e9-9412-11a35d68ccb0", "name": "", "x": 38.699967724899935, "y": -122.37479186664717, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "009758e3-b4ae-427a-9c30-f2a8bb2953d1", "name": "p1rlv868", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0b280d8d-3c4c-40e9-9412-11a35d68ccb0"}}}}, {"uuid": "74720137-2719-4bda-bd40-f1e0e83c7549", "name": "", "x": 38.69983071065769, "y": -122.37444806374667, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e5331a4f-ab91-4fea-a301-11b7afb6c8ca", "name": "p1rdm876", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "74720137-2719-4bda-bd40-f1e0e83c7549"}}}}, {"uuid": "4acdc884-dafb-47f0-9aef-0750c98c89a2", "name": "", "x": 38.69982305246386, "y": -122.37470112738258, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "41e1e576-4cc9-4fea-9d87-d436f000a675", "name": "p1rlv820", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4acdc884-dafb-47f0-9aef-0750c98c89a2"}}}}, {"uuid": "be4b1091-7833-463e-9423-9a59a5df48db", "name": "", "x": 38.70067167519556, "y": -122.37445621396152, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7c94703b-303a-4713-95c0-b2933fe0e70b", "name": "p1rdt477lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be4b1091-7833-463e-9423-9a59a5df48db"}}}}, {"uuid": "45c28223-7f02-491e-a73b-3b9744100bd2", "name": "", "x": 38.700632038038435, "y": -122.37431458299233, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5578d8b4-7c1e-444f-8d27-8c9bf733f420", "name": "p1rlv821", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "45c28223-7f02-491e-a73b-3b9744100bd2"}}}}, {"uuid": "ffdcebf1-e780-4f8b-91bb-fc038927b448", "name": "", "x": 38.700597838321514, "y": -122.37465988051781, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "08c3f5ef-c2d5-4ce2-8fc7-b665d8cbbab6", "name": "p1rlv828", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ffdcebf1-e780-4f8b-91bb-fc038927b448"}}}}, {"uuid": "f5cc1ded-e0f7-495c-ae2c-fbbe9b223fcf", "name": "", "x": 38.69822971347937, "y": -122.37575041780734, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c93c776d-68b8-4e4e-8e5e-d5e34003473c", "name": "p1rdt478lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5cc1ded-e0f7-495c-ae2c-fbbe9b223fcf"}}}}, {"uuid": "3f010d14-4b1e-42be-b585-e0ced44c54ea", "name": "", "x": 38.69822653688614, "y": -122.37611798096295, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "20ce76b6-9305-4525-b77e-b7300edc2c81", "name": "p1rlv824", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3f010d14-4b1e-42be-b585-e0ced44c54ea"}}}}, {"uuid": "ee288a4b-1410-407e-bb84-038feb7a9f5a", "name": "", "x": 38.70127438508099, "y": -122.37425546173934, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8037b713-d948-43c9-8370-fb8fcf6dec15", "name": "p1rdt479lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ee288a4b-1410-407e-bb84-038feb7a9f5a"}}}}, {"uuid": "eb04d832-c5da-4476-b767-3f3132f84fd6", "name": "", "x": 38.701326152810886, "y": -122.3743545350747, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "10373c0d-6a3c-4160-a174-22de447d4c38", "name": "p1rlv832", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eb04d832-c5da-4476-b767-3f3132f84fd6"}}}}, {"uuid": "8a561549-d427-4eb0-aff8-0cac6f22dd4a", "name": "", "x": 38.69561552385404, "y": -122.3739765254889, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "423402f9-4160-481b-9951-a955f8314075", "name": "p1rdt480lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8a561549-d427-4eb0-aff8-0cac6f22dd4a"}}}}, {"uuid": "58cd95d9-c795-4a7d-bf6a-852a7830e1c7", "name": "", "x": 38.69578897651805, "y": -122.37360932935272, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3bc35476-5839-4095-bea5-36e32450b890", "name": "p1rlv835", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "58cd95d9-c795-4a7d-bf6a-852a7830e1c7"}}}}, {"uuid": "1e7206f1-15d5-4231-864e-462f41dde77f", "name": "", "x": 38.69655114284914, "y": -122.37573403506332, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1761b021-00e0-4880-9f05-62cf67aef0e6", "name": "p1rdt481lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1e7206f1-15d5-4231-864e-462f41dde77f"}}}}, {"uuid": "cf2f06ed-eba1-449a-9286-5b45dc3920ec", "name": "", "x": 38.69650464427591, "y": -122.37599494765684, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4eb6c1b4-f09a-44a5-a13f-64051183736d", "name": "p1rlv841", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cf2f06ed-eba1-449a-9286-5b45dc3920ec"}}}}, {"uuid": "ea3ccfaa-4380-4f10-a9e3-de4b5e7d3502", "name": "", "x": 38.70357693514638, "y": -122.37510942987323, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c445ea76-5167-4d55-b0c5-cc53dadc5b5e", "name": "p1rdt482lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea3ccfaa-4380-4f10-a9e3-de4b5e7d3502"}}}}, {"uuid": "d417a786-cd49-46fd-ae63-d886ea429ad5", "name": "", "x": 38.70335811800441, "y": -122.37516485990416, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "26294827-db76-40b6-b652-1e41efdf15dc", "name": "p1rlv844", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d417a786-cd49-46fd-ae63-d886ea429ad5"}}}}, {"uuid": "0dab527d-342b-4f34-87fb-05ef650c3c36", "name": "", "x": 38.70345472163367, "y": -122.37469250108072, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3929a951-8b8b-42e9-a839-40c29e680108", "name": "p1rdm887", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0dab527d-342b-4f34-87fb-05ef650c3c36"}}}}, {"uuid": "d45f0194-8734-4ee3-9e7f-98f34d433fb6", "name": "", "x": 38.703250684927625, "y": -122.37476725706298, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "145d3757-ca09-45ca-9199-465b6b43fbb7", "name": "p1rlv846", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d45f0194-8734-4ee3-9e7f-98f34d433fb6"}}}}, {"uuid": "66e67166-f14a-476d-8648-058991b142e5", "name": "", "x": 38.70365739465258, "y": -122.37551877012066, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0318cdac-5c7b-4711-a0d7-9c7e104c8281", "name": "p1rdm888", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "66e67166-f14a-476d-8648-058991b142e5"}}}}, {"uuid": "a3ae50f4-d19a-4bfa-8ff0-1f84947d8884", "name": "", "x": 38.70348320380497, "y": -122.3754933077317, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e484d77-29ac-4903-afa3-f677283db883", "name": "p1rlv848", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a3ae50f4-d19a-4bfa-8ff0-1f84947d8884"}}}}, {"uuid": "dd460952-fe9a-4bfb-adf2-3abd1eaf4da5", "name": "", "x": 38.702921323422025, "y": -122.3755291486841, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "475b6a50-9814-4016-bb88-be5b1b2ac31d", "name": "p1rdt483lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dd460952-fe9a-4bfb-adf2-3abd1eaf4da5"}}}}, {"uuid": "b23389d5-db2a-42ee-8d67-2310f4899dc8", "name": "", "x": 38.703007845457876, "y": -122.37538641519177, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b053d449-b15b-4292-9a73-9b7d104a8e38", "name": "p1rlv845", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b23389d5-db2a-42ee-8d67-2310f4899dc8"}}}}, {"uuid": "240ea3e2-73c5-4635-bc37-fc108951680c", "name": "", "x": 38.70304524173173, "y": -122.37563909815356, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48b5535c-f00d-4b48-a23a-87f3f212302f", "name": "p1rlv851", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "240ea3e2-73c5-4635-bc37-fc108951680c"}}}}, {"uuid": "82a21e9b-7754-4024-88a0-ae654168e5df", "name": "", "x": 38.702817687028535, "y": -122.37521556434297, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5ea0f4f5-2024-45a8-9f8f-f5963e7d2727", "name": "p1rlv859", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "82a21e9b-7754-4024-88a0-ae654168e5df"}}}}, {"uuid": "669a2a11-e7f7-4f0e-b8c2-68e80fbec40b", "name": "", "x": 38.70279292587802, "y": -122.37564129224644, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "18ea7daf-9665-4d68-b255-12d41bdb2396", "name": "p1rdm892", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "669a2a11-e7f7-4f0e-b8c2-68e80fbec40b"}}}}, {"uuid": "5dc4e885-9a73-4f8e-b1ae-d50867b07dbb", "name": "", "x": 38.70291988195477, "y": -122.37578969289967, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "10611e08-75e2-4422-ac0f-cfb98c7eae4b", "name": "p1rlv855", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5dc4e885-9a73-4f8e-b1ae-d50867b07dbb"}}}}, {"uuid": "d4b2664f-dc7b-4cdb-b3b2-d960e5421cac", "name": "", "x": 38.70292245928232, "y": -122.37627268549726, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0398ef91-eeb8-4d34-b05e-e88adabdd487", "name": "p1rdm890", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d4b2664f-dc7b-4cdb-b3b2-d960e5421cac"}}}}, {"uuid": "2b9bff87-4eb3-4876-9012-61e1b232fe89", "name": "", "x": 38.703110285036146, "y": -122.37600654493566, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a95877ca-8600-4e95-82ac-c51cb82acf16", "name": "p1rlv849", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2b9bff87-4eb3-4876-9012-61e1b232fe89"}}}}, {"uuid": "9251def0-f2e1-4f6e-941b-d92daf95dca5", "name": "", "x": 38.703228109041184, "y": -122.37391642365674, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f396745a-5edb-4ab8-8bc7-2b181719cbf4", "name": "p1rdt484lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9251def0-f2e1-4f6e-941b-d92daf95dca5"}}}}, {"uuid": "49e501ea-9bde-4e92-adc9-d234bbe0089e", "name": "", "x": 38.703036634136346, "y": -122.3740291205105, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "283142ff-4884-4adc-9d4c-f8615505415a", "name": "p1rlv847", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "49e501ea-9bde-4e92-adc9-d234bbe0089e"}}}}, {"uuid": "fa8c24ff-8763-42d3-8d11-c9086c1ba728", "name": "", "x": 38.70327135825731, "y": -122.37410757698957, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e96e4c25-4664-45ae-b77c-9e0047f65c8b", "name": "p1rdm895", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa8c24ff-8763-42d3-8d11-c9086c1ba728"}}}}, {"uuid": "d321aa56-ea46-4547-b406-d12d6edaf433", "name": "", "x": 38.70311835119867, "y": -122.37414341195237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25f84b28-695b-4d32-b96c-914226444b9f", "name": "p1rlv856", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d321aa56-ea46-4547-b406-d12d6edaf433"}}}}, {"uuid": "7db6af4b-6a64-498f-a521-1854f01504d8", "name": "", "x": 38.703669352612835, "y": -122.37607068899858, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60637f4b-8538-4b21-988c-1b13adecc647", "name": "p1rdm896", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7db6af4b-6a64-498f-a521-1854f01504d8"}}}}, {"uuid": "b3c65356-acf8-47e2-8334-90564c73b6ca", "name": "", "x": 38.70391277989249, "y": -122.3760915746208, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f8d49057-9c70-4489-95bb-36b5b574e13d", "name": "p1rlv850", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b3c65356-acf8-47e2-8334-90564c73b6ca"}}}}, {"uuid": "e8a3be83-b908-4eb8-b9a2-4785c43e8598", "name": "", "x": 38.70359885298128, "y": -122.37627393150467, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "da38ec0a-f37d-4a5c-8da0-93410a8fb475", "name": "p1rdt485lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e8a3be83-b908-4eb8-b9a2-4785c43e8598"}}}}, {"uuid": "650cf4f4-5e7c-4f74-b727-66f7380cd60a", "name": "", "x": 38.703581080158116, "y": -122.37641646997498, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3464daa0-06b2-4d5d-9901-bb34050fe619", "name": "p1rdm897", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "650cf4f4-5e7c-4f74-b727-66f7380cd60a"}}}}, {"uuid": "42113e48-8448-48b0-9eb0-8fcced6b8af6", "name": "", "x": 38.703436102309, "y": -122.37626822341811, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "365eff25-8ccb-448b-894f-ad662fe6d684", "name": "p1rlv853", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "42113e48-8448-48b0-9eb0-8fcced6b8af6"}}}}, {"uuid": "05bc81c2-2d04-4cf3-a9a5-7f23fd30a9e3", "name": "", "x": 38.703390597071916, "y": -122.37449755221637, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9d9b6dee-73e1-43ab-ac9b-7d20fb77b6df", "name": "p1rdm898", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "05bc81c2-2d04-4cf3-a9a5-7f23fd30a9e3"}}}}, {"uuid": "7e983a28-7cb7-4af9-b2ce-4ffd390611f0", "name": "", "x": 38.70324715473682, "y": -122.37463680676714, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32142941-c546-4356-ba80-123b9128b5de", "name": "p1rlv852", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7e983a28-7cb7-4af9-b2ce-4ffd390611f0"}}}}, {"uuid": "897928d1-20b8-4749-8364-0b0632b5ca5a", "name": "", "x": 38.70348000850968, "y": -122.37489531232455, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5401d366-a5a2-4753-82b7-ce4fa08a1227", "name": "p1rdt486lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "897928d1-20b8-4749-8364-0b0632b5ca5a"}}}}, {"uuid": "4d064814-1c38-4d96-9a35-d3efdb32c61b", "name": "", "x": 38.70361123258167, "y": -122.37531216321483, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e5e11ab-e042-4038-85c4-162521871722", "name": "p1rdm899", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d064814-1c38-4d96-9a35-d3efdb32c61b"}}}}, {"uuid": "8ee66b9b-0ed0-4790-a55e-d4442e53b1b7", "name": "", "x": 38.703799916455935, "y": -122.3752070170666, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a28cc17a-125d-4b7b-a697-230e3f8853b5", "name": "p1rlv857", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8ee66b9b-0ed0-4790-a55e-d4442e53b1b7"}}}}, {"uuid": "738b4b76-6e5f-44ae-a070-587d3e0c8e90", "name": "", "x": 38.70291683599943, "y": -122.37353789637632, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "47fbd02f-6c12-4bd6-9d6d-2e0cddbfcd88", "name": "p1rdt487lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "738b4b76-6e5f-44ae-a070-587d3e0c8e90"}}}}, {"uuid": "db92746b-b776-4bb9-bdff-ba0791a8c89d", "name": "", "x": 38.702960786540345, "y": -122.373328259674, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2461b6f0-9a40-4b6f-9669-be479da039f3", "name": "p1rlv854", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "db92746b-b776-4bb9-bdff-ba0791a8c89d"}}}}, {"uuid": "eafb6508-d461-4b86-9216-758ab0e8ab85", "name": "", "x": 38.699795636236686, "y": -122.375786328938, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e517b810-e6b9-4c89-b47d-1921fcf88edc", "name": "p1rdt488lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eafb6508-d461-4b86-9216-758ab0e8ab85"}}}}, {"uuid": "b72997ac-862f-46db-a691-047ec1506a3f", "name": "", "x": 38.69977340921936, "y": -122.37552954904456, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "09a7be46-a1bf-459d-836b-beb64324809b", "name": "p1rlv863", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b72997ac-862f-46db-a691-047ec1506a3f"}}}}, {"uuid": "9b4b2a81-aca2-4dfe-b222-4bd3d89f2356", "name": "", "x": 38.699886904548684, "y": -122.37583204363513, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d7f4223-382b-4b9a-9157-baede39de271", "name": "p1rdm901", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9b4b2a81-aca2-4dfe-b222-4bd3d89f2356"}}}}, {"uuid": "d07a2474-09ad-4312-9dd3-89afa4b4b404", "name": "", "x": 38.699878813753116, "y": -122.37554765578757, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6a07d30f-6909-4d74-be8a-1ff8343b4419", "name": "p1rlv861", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d07a2474-09ad-4312-9dd3-89afa4b4b404"}}}}, {"uuid": "65525a66-1773-4ea2-b271-524a8bc99e2f", "name": "", "x": 38.69880247694915, "y": -122.37480953523237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25637062-8ca3-4694-a27b-7be93e89fe1f", "name": "p1rdt489lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65525a66-1773-4ea2-b271-524a8bc99e2f"}}}}, {"uuid": "3d4e34d0-f420-48ce-9811-dd970d236fa2", "name": "", "x": 38.698651585469364, "y": -122.37471132813891, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1fb4003d-498a-494d-89ca-f222d921f63a", "name": "p1rlv869", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3d4e34d0-f420-48ce-9811-dd970d236fa2"}}}}, {"uuid": "b6387c92-387a-45c9-87dc-051d39df6ccd", "name": "", "x": 38.759686999725254, "y": -122.44226913015365, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "601a7504-69fc-4c21-a1d8-1a59751d439c", "name": "p1rdm7860", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b6387c92-387a-45c9-87dc-051d39df6ccd"}}}}, {"uuid": "daba7bcc-f84f-4392-823d-cf77c8291e5e", "name": "", "x": 38.759611722163974, "y": -122.44160216619036, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fd7a84bb-8aa4-4668-9791-a363741823e9", "name": "p1rlv7783", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "daba7bcc-f84f-4392-823d-cf77c8291e5e"}}}}, {"uuid": "f417b4b4-aaed-4be9-aa1d-29ac29530106", "name": "", "x": 38.759987059360896, "y": -122.4422362456647, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8ae14df0-ab3b-47ba-9f83-c09f03999c76", "name": "p1rdt3776lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f417b4b4-aaed-4be9-aa1d-29ac29530106"}}}}, {"uuid": "3d1135bd-0816-4b36-bbc4-3735e50292b3", "name": "", "x": 38.760119212628396, "y": -122.44219670856471, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "391504f7-3b2f-47f0-aadd-47de5c89b16b", "name": "p1rdm7861", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3d1135bd-0816-4b36-bbc4-3735e50292b3"}}}}, {"uuid": "811d2f8e-757f-4164-9b75-2c45d474b794", "name": "", "x": 38.76011816883335, "y": -122.4419780350059, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "24e665a0-3ba6-46a7-bc02-327b6f77c409", "name": "p1rlv7784", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "811d2f8e-757f-4164-9b75-2c45d474b794"}}}}, {"uuid": "08c1e17d-fdf8-42ae-9eb9-e06c74feb269", "name": "", "x": 38.75891156323847, "y": -122.44466513486701, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4662f3f5-e75b-4b75-a6d6-7ada745d5cca", "name": "p1rdt3777lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "08c1e17d-fdf8-42ae-9eb9-e06c74feb269"}}}}, {"uuid": "44fc4fff-3b31-4f55-8b28-afc7b1803074", "name": "", "x": 38.75891004710453, "y": -122.44564742267218, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9af62e3c-9357-4505-a2f6-3b4252dab81b", "name": "p1rlv7786", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "44fc4fff-3b31-4f55-8b28-afc7b1803074"}}}}, {"uuid": "d07200f5-dcef-4fc8-b31d-44f9a58cb3af", "name": "", "x": 38.75892205855218, "y": -122.44438129888907, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "90158ee6-01aa-48ce-867f-8e459e7a5e09", "name": "p1rdm7862", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d07200f5-dcef-4fc8-b31d-44f9a58cb3af"}}}}, {"uuid": "2c94939f-e53a-4390-a61c-2fdeaf2224ef", "name": "", "x": 38.758813649325106, "y": -122.44432459271447, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1571d1a3-a151-4972-8cb1-aeb36b660abc", "name": "p1rlv7785", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2c94939f-e53a-4390-a61c-2fdeaf2224ef"}}}}, {"uuid": "2abed101-61b0-40f8-9656-14aa9bb44653", "name": "", "x": 38.665452782208654, "y": -122.46042242219686, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e734d7a2-9161-41c0-ba78-9f9f87120acd", "name": "p1rdt5098lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2abed101-61b0-40f8-9656-14aa9bb44653"}}}}, {"uuid": "349e93eb-bbeb-4cf6-962a-1da6b3e846fb", "name": "", "x": 38.66549109565642, "y": -122.46029967067366, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "09926231-b077-4aa6-afd8-acf89744865a", "name": "p1rlv10453", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "349e93eb-bbeb-4cf6-962a-1da6b3e846fb"}}}}, {"uuid": "ec821adf-cbe4-4f10-99c3-85668031f401", "name": "", "x": 38.665383753359855, "y": -122.46047289225729, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9a639e8d-ac8c-46e8-a4b5-6c551612b209", "name": "p1rlv10468", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ec821adf-cbe4-4f10-99c3-85668031f401"}}}}, {"uuid": "7096e027-1f66-45c2-8594-9b2f6171bb76", "name": "", "x": 38.665480227274244, "y": -122.45989744815324, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d40fc87f-1b73-4ed4-a397-dbc94312dcad", "name": "p1rlv10482", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7096e027-1f66-45c2-8594-9b2f6171bb76"}}}}, {"uuid": "1761a6d4-5d26-409e-b522-e6548258829b", "name": "", "x": 38.665521469030836, "y": -122.46102359049253, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "efd01236-6ba3-424e-829b-3f3950ce6265", "name": "p1rlv10517", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1761a6d4-5d26-409e-b522-e6548258829b"}}}}, {"uuid": "9dc653ac-d7a4-4f89-a699-b360eff11ffe", "name": "", "x": 38.65349301133138, "y": -122.48412729471077, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "91754be7-2a91-4a0e-9856-43d08ecc7c70", "name": "p1rdt5548lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9dc653ac-d7a4-4f89-a699-b360eff11ffe"}}}}, {"uuid": "32548a03-8760-4329-b730-0eb4180d6402", "name": "", "x": 38.65285475188867, "y": -122.48386195652688, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "773a6b9e-d708-4f7c-a901-9406bcc3dcde", "name": "p1rlv11503", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "32548a03-8760-4329-b730-0eb4180d6402"}}}}, {"uuid": "6daffc64-545f-48b6-b9dd-c01a7caf0cd9", "name": "", "x": 38.65294527277444, "y": -122.48395324626152, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f7efbb32-55d4-409b-a37f-bf01d0620d40", "name": "p1rlv19645", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6daffc64-545f-48b6-b9dd-c01a7caf0cd9"}}}}, {"uuid": "d52b4ce6-a2a9-4d89-b20c-badbd780ff8b", "name": "", "x": 38.65351451941317, "y": -122.48429393725958, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c4c77c78-e261-4d17-93ff-caad4d86246b", "name": "p1rdm11706", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d52b4ce6-a2a9-4d89-b20c-badbd780ff8b"}}}}, {"uuid": "5c8ae331-4dc1-4b73-8eb7-19d3d44f688f", "name": "", "x": 38.65313573125618, "y": -122.48422769840043, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9e90f763-682e-4771-976c-9cd736b72133", "name": "p1rlv19640", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5c8ae331-4dc1-4b73-8eb7-19d3d44f688f"}}}}, {"uuid": "e12efe67-ffe9-45e6-8d49-c58f292ff6e8", "name": "", "x": 38.65401139999537, "y": -122.48253201007375, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "15ae4af0-db43-4f1b-bd8c-c6be31d034aa", "name": "p1rdm11719", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e12efe67-ffe9-45e6-8d49-c58f292ff6e8"}}}}, {"uuid": "3ba0dc35-2b37-4a80-ade1-eac0f9902e85", "name": "", "x": 38.65384898920333, "y": -122.48248720829615, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "84b9d44e-2c8d-4cee-a9d2-327a41ab8dad", "name": "p1rlv11513", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3ba0dc35-2b37-4a80-ade1-eac0f9902e85"}}}}, {"uuid": "0bf7988f-5ebc-458b-826c-ec6efad5e132", "name": "", "x": 38.65406486613757, "y": -122.48238206755065, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "05b867e6-2f18-49e7-9869-55bd5048c201", "name": "p1rdt5557lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0bf7988f-5ebc-458b-826c-ec6efad5e132"}}}}, {"uuid": "dcf43b02-4298-41d4-ad1c-92d87578993e", "name": "", "x": 38.654054728485086, "y": -122.4821409504333, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "effa94d0-34ae-4cbe-b8da-fd1693d47b3a", "name": "p1rdm11720", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dcf43b02-4298-41d4-ad1c-92d87578993e"}}}}, {"uuid": "4931ad26-9e32-4cb4-85cd-f7485acc5477", "name": "", "x": 38.65329740432264, "y": -122.48206595565533, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bf457d88-958c-446a-9584-73be8c609bbe", "name": "p1rlv19574", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4931ad26-9e32-4cb4-85cd-f7485acc5477"}}}}, {"uuid": "f173e132-e022-46a1-b3cf-6fb8b348146f", "name": "", "x": 38.655212268996365, "y": -122.4810200626239, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d5838960-8556-4e4a-95e9-8ba9ffc85141", "name": "p1rdt5560lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f173e132-e022-46a1-b3cf-6fb8b348146f"}}}}, {"uuid": "edd6a9c5-95e0-4cbc-9328-cd8be4f904c6", "name": "", "x": 38.655330800417374, "y": -122.48132726741721, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "86d82a1e-1596-4fb3-9f3d-44c9553396d2", "name": "p1rlv11516", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "edd6a9c5-95e0-4cbc-9328-cd8be4f904c6"}}}}, {"uuid": "3fcef969-b8f3-49c8-ad03-1838c6eac971", "name": "", "x": 38.65375449158675, "y": -122.48352206240394, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "133a0221-0cd5-46d2-af84-e80e7951c96d", "name": "p1rdt5561lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3fcef969-b8f3-49c8-ad03-1838c6eac971"}}}}, {"uuid": "5a41b4bf-e666-4b1b-834e-521504b72b04", "name": "", "x": 38.65442296031636, "y": -122.48389667390005, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "179d1d84-0dfe-4920-a039-009f33bc1d8d", "name": "p1rlv11517", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5a41b4bf-e666-4b1b-834e-521504b72b04"}}}}, {"uuid": "2f613491-2ee1-4f3f-9d9a-e20f2d3640a5", "name": "", "x": 38.65445021577995, "y": -122.48126863552662, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8deb73b9-51fc-447d-9da7-14a6dccff646", "name": "p1rdt5564lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2f613491-2ee1-4f3f-9d9a-e20f2d3640a5"}}}}, {"uuid": "5397d76e-8423-4b26-b76a-ed3deff45a7c", "name": "", "x": 38.65452001830409, "y": -122.48139057750333, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f8f0f8a2-f528-45bd-8fbd-22f6699fe7e0", "name": "p1rlv11521", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5397d76e-8423-4b26-b76a-ed3deff45a7c"}}}}, {"uuid": "d1eb9046-a524-4a94-b3ce-001d80998cd8", "name": "", "x": 38.653503595754145, "y": -122.48459005947156, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "95a5450a-6630-41b8-863f-0c1f3fcfa7ab", "name": "p1rdt5566lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1eb9046-a524-4a94-b3ce-001d80998cd8"}}}}, {"uuid": "c57fc713-783d-4b5e-a8bc-8461f19caa7a", "name": "", "x": 38.652722315413676, "y": -122.48448349500988, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "69eba934-3f80-4abc-b5e8-9cdc79aa05a3", "name": "p1rlv11523", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c57fc713-783d-4b5e-a8bc-8461f19caa7a"}}}}, {"uuid": "bb4f6529-f339-4286-bf82-44fc21a9adef", "name": "", "x": 38.65290868561374, "y": -122.48312227902461, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "613d178b-a566-408d-bad0-e4a170eea971", "name": "p1rdt5568lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bb4f6529-f339-4286-bf82-44fc21a9adef"}}}}, {"uuid": "317c2a79-f30d-438a-93a0-556de85f2806", "name": "", "x": 38.65290346928153, "y": -122.48306882713341, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b97ebb0-09a4-4c42-a10e-e3aff344aa44", "name": "p1rlv11526", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "317c2a79-f30d-438a-93a0-556de85f2806"}}}}, {"uuid": "aff86a89-8b6f-444c-a1a3-218129998f5b", "name": "", "x": 38.6535709305957, "y": -122.48453866803233, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0460a67f-dcc1-4829-99f8-7a0b6a8cedbc", "name": "p1rdm11742", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aff86a89-8b6f-444c-a1a3-218129998f5b"}}}}, {"uuid": "3e312389-c9f7-417a-be1e-7d41819eff67", "name": "", "x": 38.652965879895014, "y": -122.48453921146539, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "21b18539-fba6-4b52-b8bf-38c2a6c4abfb", "name": "p1rlv11533", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e312389-c9f7-417a-be1e-7d41819eff67"}}}}, {"uuid": "f3df1aff-a25f-42fd-82d9-c0e51c70bc8f", "name": "", "x": 38.65330877367878, "y": -122.48464018641775, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8f0e181a-fa89-4c5d-a1cb-6080f91331da", "name": "p1rlv19643", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f3df1aff-a25f-42fd-82d9-c0e51c70bc8f"}}}}, {"uuid": "6e5af62d-2fbe-4dfd-b7d1-8a1040a5ab7e", "name": "", "x": 38.65345372369736, "y": -122.48479084547154, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "248e065d-80ed-4926-9625-295c83da6b61", "name": "p1rdt5574lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6e5af62d-2fbe-4dfd-b7d1-8a1040a5ab7e"}}}}, {"uuid": "981c76fc-50f5-4e40-ae36-c33893f91beb", "name": "", "x": 38.65346288080924, "y": -122.48484594711942, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6554d73d-5cf7-4531-a524-78e70b36fd8d", "name": "p1rdm11743", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "981c76fc-50f5-4e40-ae36-c33893f91beb"}}}}, {"uuid": "365c2b7e-424c-4246-8ec1-4d1f39dbbcbb", "name": "", "x": 38.65324635107003, "y": -122.48479003561559, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "813f887e-6807-4ffc-90bf-bd30cde9a9df", "name": "p1rlv19610", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "365c2b7e-424c-4246-8ec1-4d1f39dbbcbb"}}}}, {"uuid": "e1ac22f0-6134-44d1-8d4f-f2948df6203a", "name": "", "x": 38.65211076864418, "y": -122.48360342410952, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "21ef4ae6-b80e-49f1-8d00-1cb6e27bc8f9", "name": "p1rdt5577lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e1ac22f0-6134-44d1-8d4f-f2948df6203a"}}}}, {"uuid": "c8697d6c-15d8-4c61-a6de-4f056fdb7afb", "name": "", "x": 38.65211742852992, "y": -122.48423500000004, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1148946c-8c37-4482-afce-5082cd2b7ad4", "name": "p1rdt5577lv-p1rlv11540x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c8697d6c-15d8-4c61-a6de-4f056fdb7afb"}}}}, {"uuid": "53948b43-71df-47cc-80ba-c157d05bf7d7", "name": "", "x": 38.65207242155051, "y": -122.48424681497777, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f79b14c8-e77d-49c1-9336-e7407ad4c94d", "name": "p1rlv11540", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "53948b43-71df-47cc-80ba-c157d05bf7d7"}}}}, {"uuid": "2a1c2b55-25ee-42cc-8a93-81ebf49aae00", "name": "", "x": 38.65279916105022, "y": -122.4835175838475, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "752bcf04-7a44-42b0-9a46-44c243b78eb5", "name": "p1rdt5577lv-p1rlv19608x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2a1c2b55-25ee-42cc-8a93-81ebf49aae00"}}}}, {"uuid": "bcf33a8f-8984-4542-a3db-d89c5f01df6e", "name": "", "x": 38.652193358258536, "y": -122.48306224209226, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f917b142-d59f-4a51-8c3b-913feb53411d", "name": "p1rlv19608", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bcf33a8f-8984-4542-a3db-d89c5f01df6e"}}}}, {"uuid": "4483501b-cdce-4aa1-833e-1d89f54498eb", "name": "", "x": 38.66703472717699, "y": -122.47875999417263, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a5559c15-cdac-4a4d-a2a0-b99c9befb310", "name": "p1rdm13355", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4483501b-cdce-4aa1-833e-1d89f54498eb"}}}}, {"uuid": "8e65ba3a-d5dc-4516-9dcc-39816f28eb6c", "name": "", "x": 38.666963198566314, "y": -122.47888695389291, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1564c5f9-8b80-41b4-af09-2a55dee0718b", "name": "p1rlv13033", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8e65ba3a-d5dc-4516-9dcc-39816f28eb6c"}}}}, {"uuid": "358567fb-7670-4972-bc4a-8361e82ef171", "name": "", "x": 38.66717310843214, "y": -122.47884342821176, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a9859b30-0238-493e-be1a-cb6717413ba9", "name": "p1rdt6261lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "358567fb-7670-4972-bc4a-8361e82ef171"}}}}, {"uuid": "9605bc5c-3d00-4414-ba84-af1384312959", "name": "", "x": 38.667278908257714, "y": -122.47895363367641, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ba5e6363-0b23-4726-8013-f3d040511005", "name": "p1rdm13356", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9605bc5c-3d00-4414-ba84-af1384312959"}}}}, {"uuid": "d06077af-253f-4440-a72d-e4097453ec3e", "name": "", "x": 38.66717220353242, "y": -122.4792762580999, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "23aae8f1-8b9f-4453-9643-b49ffdc80889", "name": "p1rlv13036", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d06077af-253f-4440-a72d-e4097453ec3e"}}}}, {"uuid": "1edf8d84-7823-4da1-a9cf-7d60fa171495", "name": "", "x": 38.66655673727605, "y": -122.48006632205775, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c2172b57-622b-44c1-8388-f1e2b1def312", "name": "p1rdt6262lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1edf8d84-7823-4da1-a9cf-7d60fa171495"}}}}, {"uuid": "e08f8ab0-1195-4113-aad2-d08a9ef594fb", "name": "", "x": 38.66654421125099, "y": -122.47991300856037, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3b7bff1-90da-4ee2-8a0f-8e291a7e8ac8", "name": "p1rlv13034", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e08f8ab0-1195-4113-aad2-d08a9ef594fb"}}}}, {"uuid": "cc8e6a88-7c99-4b4d-a6a2-b5b5983b91f3", "name": "", "x": 38.66654838989604, "y": -122.48021581199129, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c6839f65-9d3b-4bd6-89a4-0c8feb33e98a", "name": "p1rlv13040", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc8e6a88-7c99-4b4d-a6a2-b5b5983b91f3"}}}}, {"uuid": "ff16a8d5-a522-4782-b3a5-3bae4ab23764", "name": "", "x": 38.66690377458573, "y": -122.48086176489268, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4717b000-fd39-4647-9fbd-5152323dacee", "name": "p1rdt6263lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ff16a8d5-a522-4782-b3a5-3bae4ab23764"}}}}, {"uuid": "1220e772-0453-4a0b-b571-cc0a62841ce9", "name": "", "x": 38.66687779947186, "y": -122.48081912313049, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c6d309ef-b082-4022-a265-4891cdcd6db9", "name": "p1rlv13035", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1220e772-0453-4a0b-b571-cc0a62841ce9"}}}}, {"uuid": "03fd6629-3635-4d50-8480-1e1e39c348ec", "name": "", "x": 38.66255558019544, "y": -122.47741013877915, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e916c16-525d-4092-b627-ad44b4bf4ee8", "name": "p1rdt6264lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "03fd6629-3635-4d50-8480-1e1e39c348ec"}}}}, {"uuid": "5b083b59-faa7-407f-94c6-95a8fb7db4e9", "name": "", "x": 38.66254447908395, "y": -122.47746230770055, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7f5d04aa-74fb-4d1a-ac91-6c01a56a94b5", "name": "p1rlv13037", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5b083b59-faa7-407f-94c6-95a8fb7db4e9"}}}}, {"uuid": "f42abcc6-9394-4f6f-afa6-91874259a980", "name": "", "x": 38.66061026704863, "y": -122.48036217979423, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e6bb5544-e583-4ded-9a10-23be70f5598e", "name": "p1rdt6265lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f42abcc6-9394-4f6f-afa6-91874259a980"}}}}, {"uuid": "c47455e5-7a81-46e7-8b23-13a1b138d9b2", "name": "", "x": 38.660735364357585, "y": -122.48075957945385, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9a8b4502-31fd-4dce-8717-9860880075b4", "name": "p1rlv13038", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c47455e5-7a81-46e7-8b23-13a1b138d9b2"}}}}, {"uuid": "768cb989-5a66-410d-bed8-df0e10c19744", "name": "", "x": 38.660452382345134, "y": -122.47994557664096, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "34d43081-e4a3-4f1b-8b90-5965458452d0", "name": "p1rlv13039", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "768cb989-5a66-410d-bed8-df0e10c19744"}}}}, {"uuid": "c00988a8-164a-4ae9-87ff-eda2c2eb1e48", "name": "", "x": 38.66246119968208, "y": -122.47659512275703, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8af5f9d5-965c-4a0c-a811-67d3bed744ee", "name": "p1rdt6266lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c00988a8-164a-4ae9-87ff-eda2c2eb1e48"}}}}, {"uuid": "c8e8dfff-c156-4d84-b476-8dbf65fb2e45", "name": "", "x": 38.66248671917567, "y": -122.47655203872152, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60144ce1-d4d6-4725-b543-f881894356a5", "name": "p1rlv13041", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c8e8dfff-c156-4d84-b476-8dbf65fb2e45"}}}}, {"uuid": "62fb1dd6-10cf-453b-a9db-bf538e6415e4", "name": "", "x": 38.6652765486321, "y": -122.4794367281912, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d0ddd898-3193-4bff-80f4-fd4a7eae9aec", "name": "p1rdt6267lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "62fb1dd6-10cf-453b-a9db-bf538e6415e4"}}}}, {"uuid": "74b1a318-c73f-40ae-a0e6-13095293a6a8", "name": "", "x": 38.665302069155366, "y": -122.47939364345397, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "296cd07e-c2e3-4031-abad-9c870a65105d", "name": "p1rlv13042", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "74b1a318-c73f-40ae-a0e6-13095293a6a8"}}}}, {"uuid": "f4e4a449-0026-4c8d-b73e-666ad21ff0e4", "name": "", "x": 38.64756555827549, "y": -122.50910380696413, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b1155c2c-544c-45f4-969f-b3ec4f6773bb", "name": "p1rdt6488lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f4e4a449-0026-4c8d-b73e-666ad21ff0e4"}}}}, {"uuid": "941c708e-42ff-43af-9af5-da57099f33ff", "name": "", "x": 38.647565542168486, "y": -122.50904985776398, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3243ca2f-a97e-4fbc-981d-85eded2e5e6b", "name": "p1rlv13513", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "941c708e-42ff-43af-9af5-da57099f33ff"}}}}, {"uuid": "59de6cf1-c8b9-4799-9a3e-2d4543e023f1", "name": "", "x": 38.66460136270918, "y": -122.44791156272083, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "555453a3-3fb7-426a-bbd2-9e588d4bd01d", "name": "p1rdt6578lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59de6cf1-c8b9-4799-9a3e-2d4543e023f1"}}}}, {"uuid": "73222e13-9809-4b5b-b542-81f2e9da8236", "name": "", "x": 38.66482282070209, "y": -122.4484080912382, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b0ca6e47-afec-4d61-885a-e38176b32444", "name": "p1rlv13823", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "73222e13-9809-4b5b-b542-81f2e9da8236"}}}}, {"uuid": "89f1ffe4-82cc-44f4-b229-a1afaf6f6224", "name": "", "x": 38.66450541345186, "y": -122.44798523933892, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b2fe65b3-6fcc-4416-bca4-9a0f6551b801", "name": "p1rdm14192", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "89f1ffe4-82cc-44f4-b229-a1afaf6f6224"}}}}, {"uuid": "3480b5cb-c591-42d2-9162-b0b478d1a56f", "name": "", "x": 38.664643133522475, "y": -122.44852441239391, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "47a7519a-b550-41e6-99e3-c2115db425fe", "name": "p1rlv13789", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3480b5cb-c591-42d2-9162-b0b478d1a56f"}}}}, {"uuid": "05f1416d-d004-448f-b835-8e7320ea9e88", "name": "", "x": 38.664533911991846, "y": -122.4482953651979, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "94ac9254-cdbf-4864-b22b-bcfb0a827700", "name": "p1rlv13796", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "05f1416d-d004-448f-b835-8e7320ea9e88"}}}}, {"uuid": "91603163-b327-419b-a562-9c486068b876", "name": "", "x": 38.66474807177311, "y": -122.44784544493244, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e0be7c1-65b8-4de4-89f2-56b6bf1ea321", "name": "p1rdm14194", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "91603163-b327-419b-a562-9c486068b876"}}}}, {"uuid": "51acf417-9cd8-46f7-97c9-1dcf69d8d859", "name": "", "x": 38.664827245819765, "y": -122.44803626546826, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "028d5ead-7c34-400b-bcc1-c4d706c965d3", "name": "p1rlv13814", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "51acf417-9cd8-46f7-97c9-1dcf69d8d859"}}}}, {"uuid": "99ed1f5c-706f-4524-beb7-df5068132667", "name": "", "x": 38.66661910169782, "y": -122.45155134514903, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5de250a8-ecca-4ab4-9f09-685aaf92d13d", "name": "p1rdt6580lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "99ed1f5c-706f-4524-beb7-df5068132667"}}}}, {"uuid": "c929ea7a-c3b7-4391-8edc-8285bd035f71", "name": "", "x": 38.666738131523914, "y": -122.4513475088475, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "251f270f-4238-4fe6-8ab3-f884fca7a42d", "name": "p1rlv13791", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c929ea7a-c3b7-4391-8edc-8285bd035f71"}}}}, {"uuid": "b64d8094-1b15-4af2-acb7-1e043d25b76f", "name": "", "x": 38.66668551808711, "y": -122.45165826434774, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ab29ca66-d59b-4aa6-b5f6-165add0bc331", "name": "p1rlv13810", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b64d8094-1b15-4af2-acb7-1e043d25b76f"}}}}, {"uuid": "52721818-3941-4aff-9668-b15d64e4bdbd", "name": "", "x": 38.666731383536465, "y": -122.45183033352055, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "99957459-46a6-4b2b-9813-69b11ca7dad1", "name": "p1rlv13815", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "52721818-3941-4aff-9668-b15d64e4bdbd"}}}}, {"uuid": "247043b9-09d5-4c87-b578-344fd897a004", "name": "", "x": 38.66641388074643, "y": -122.4513844669654, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "36c12a74-a2ca-439a-a69f-308dd5cb1207", "name": "p1rlv13819", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "247043b9-09d5-4c87-b578-344fd897a004"}}}}, {"uuid": "ea0e7b78-57d9-4a45-8c88-1895800c3377", "name": "", "x": 38.66518206185532, "y": -122.44754723338062, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4d944119-3782-49dd-8b24-1f68d8ee687c", "name": "p1rdt6584lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea0e7b78-57d9-4a45-8c88-1895800c3377"}}}}, {"uuid": "d1cbf045-63a5-47f4-8bc1-deba3702bf62", "name": "", "x": 38.66553515936385, "y": -122.4484945814938, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e96bcc5b-07c5-4289-aec4-0224395c5e8a", "name": "p1rlv13817", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1cbf045-63a5-47f4-8bc1-deba3702bf62"}}}}, {"uuid": "a2f9db05-7e24-4244-8ad2-e1510b25c7d1", "name": "", "x": 38.664864895136674, "y": -122.44777558197904, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "39af24f1-0fa2-465e-a288-2b620d9e9d59", "name": "p1rdm14215", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a2f9db05-7e24-4244-8ad2-e1510b25c7d1"}}}}, {"uuid": "feda626a-d10e-404b-8da3-429c769d4502", "name": "", "x": 38.66522828205339, "y": -122.4483934862407, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "accec892-a236-462d-b714-1178393ec992", "name": "p1rlv13801", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "feda626a-d10e-404b-8da3-429c769d4502"}}}}, {"uuid": "8c3e1a23-2e50-4e2b-bd42-b64588a6a090", "name": "", "x": 38.66526883647157, "y": -122.44743914288946, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32db643a-7c82-4816-8629-7935cab09567", "name": "p1rdm14218", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8c3e1a23-2e50-4e2b-bd42-b64588a6a090"}}}}, {"uuid": "3993ede8-b98b-4f7e-8582-45a688300ddf", "name": "", "x": 38.66568002523225, "y": -122.4480376675357, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6ade9991-a857-4619-8094-c18f824aaeb9", "name": "p1rlv13822", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3993ede8-b98b-4f7e-8582-45a688300ddf"}}}}, {"uuid": "c957710d-5b59-48d4-a705-163d7bef81c0", "name": "", "x": 38.665376485198, "y": -122.44733486613728, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e81f150f-30cd-4c9a-b5b7-7a633633702d", "name": "p1rdm14216", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c957710d-5b59-48d4-a705-163d7bef81c0"}}}}, {"uuid": "0640235f-69e2-44df-a002-75850f23e028", "name": "", "x": 38.66561322577763, "y": -122.44785029518839, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c26fba44-3b81-47de-81e6-522f2daf0534", "name": "p1rlv13807", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0640235f-69e2-44df-a002-75850f23e028"}}}}, {"uuid": "9a67951a-5d21-4aaf-8cf1-055c0e9b6ed4", "name": "", "x": 38.6660700064695, "y": -122.44833835279438, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9c587698-7940-4edb-9105-f31f1304f7e9", "name": "p1rdt6587lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9a67951a-5d21-4aaf-8cf1-055c0e9b6ed4"}}}}, {"uuid": "94a40471-e692-4c82-9db0-8a67ada7ed7d", "name": "", "x": 38.66604401958438, "y": -122.44829572341504, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1c795ac7-3b49-4158-996d-2fb1f0337847", "name": "p1rlv13808", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "94a40471-e692-4c82-9db0-8a67ada7ed7d"}}}}, {"uuid": "fa34ac6d-08b7-48d7-a2f6-0fb2f91ccd62", "name": "", "x": 38.665782733034895, "y": -122.44688743442987, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "61045f72-ca3d-4e0d-ac3d-db5fbf099b38", "name": "p1rdt6588lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa34ac6d-08b7-48d7-a2f6-0fb2f91ccd62"}}}}, {"uuid": "18f4c8ab-3825-40dd-ae7c-e806892501d8", "name": "", "x": 38.66551610253854, "y": -122.44636826305491, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "687996da-ab03-4544-b0d9-b79b8ac88e95", "name": "p1rlv13809", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "18f4c8ab-3825-40dd-ae7c-e806892501d8"}}}}, {"uuid": "774d8c44-6377-428c-89ae-01326c5972f4", "name": "", "x": 38.66470818578833, "y": -122.44621086682648, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a289017a-8ab9-4412-857a-694b3aa2c63d", "name": "p1rdt6590lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "774d8c44-6377-428c-89ae-01326c5972f4"}}}}, {"uuid": "aca2fbd4-467d-4bf7-8341-2b23f9d30c2b", "name": "", "x": 38.66472254581389, "y": -122.44626167635215, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a2caa70b-9143-4676-834b-bfc7cb41330c", "name": "p1rlv13820", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aca2fbd4-467d-4bf7-8341-2b23f9d30c2b"}}}}, {"uuid": "51a9a4f7-cb5d-4fe5-9213-71fe12585bae", "name": "", "x": 38.66450288065584, "y": -122.44662624081425, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8a7c2e99-857f-4119-be4a-daaca586f056", "name": "p1rdt6591lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "51a9a4f7-cb5d-4fe5-9213-71fe12585bae"}}}}, {"uuid": "bd002735-2c22-4505-9f8a-7fed31956b37", "name": "", "x": 38.664476893151246, "y": -122.44658361298364, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "66e6c732-919a-4851-9f76-5580ea71669d", "name": "p1rlv13821", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bd002735-2c22-4505-9f8a-7fed31956b37"}}}}, {"uuid": "53ce4353-6591-4b16-8c1b-6a572722d9d2", "name": "", "x": 38.650925590961236, "y": -122.47648370205337, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8ad975da-cce7-49cb-be78-20c4abf8975e", "name": "p1rdt7286lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "53ce4353-6591-4b16-8c1b-6a572722d9d2"}}}}, {"uuid": "1f533a6b-7428-41c4-9100-81e5b64c526d", "name": "", "x": 38.65091178622824, "y": -122.47653475192051, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "17bf6d8f-8215-4294-b921-cc3e34476f1e", "name": "p1rlv15585", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1f533a6b-7428-41c4-9100-81e5b64c526d"}}}}, {"uuid": "7bd1bc68-a2a4-45a5-8c9c-3c8b6a13e850", "name": "", "x": 38.650690731688435, "y": -122.47687130836174, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "56d21681-3c57-4575-af17-f2bbf9874a10", "name": "p1rdt7289lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7bd1bc68-a2a4-45a5-8c9c-3c8b6a13e850"}}}}, {"uuid": "ab2a10f9-9b8c-4c25-a988-03a6d071f099", "name": "", "x": 38.6509152754639, "y": -122.47733687713344, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ef2a4478-4644-4bd3-9548-ab1d0be338b5", "name": "p1rlv15590", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ab2a10f9-9b8c-4c25-a988-03a6d071f099"}}}}, {"uuid": "9baa86b9-b0df-4541-ad87-bc928134642d", "name": "", "x": 38.650433450846926, "y": -122.47639803350314, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c04c9ad1-4277-47de-9cec-9ce86e17b4f1", "name": "p1rlv15591", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9baa86b9-b0df-4541-ad87-bc928134642d"}}}}, {"uuid": "c5d952d0-6fca-404d-bafd-c21da4301161", "name": "", "x": 38.64948736383664, "y": -122.47579982496423, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a9b0c16f-f433-4aa1-8d00-dc1573dfb5e3", "name": "p1rdt7293lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c5d952d0-6fca-404d-bafd-c21da4301161"}}}}, {"uuid": "90c36dbe-020f-474a-abb4-c1e99f474701", "name": "", "x": 38.64940610565797, "y": -122.47576594155083, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "629e2259-2a59-4b20-b8bf-7b3b2c4a48f9", "name": "p1rlv15595", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "90c36dbe-020f-474a-abb4-c1e99f474701"}}}}, {"uuid": "cee60e10-1306-4dec-9856-0151cfeda93e", "name": "", "x": 38.64955676013305, "y": -122.47582982129457, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "af6b7d1b-896f-44ac-8038-748c74507253", "name": "p1rlv15598", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cee60e10-1306-4dec-9856-0151cfeda93e"}}}}, {"uuid": "15fe8ec5-07e2-4234-a2a7-51372760b4ae", "name": "", "x": 38.654450185149294, "y": -122.50266398158654, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2c1ea087-8a4d-49ca-af35-b86aed849c98", "name": "p1rdm16003", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "15fe8ec5-07e2-4234-a2a7-51372760b4ae"}}}}, {"uuid": "a779adaf-c56f-4ee1-b671-6b1ebacd5ed8", "name": "", "x": 38.65486320126965, "y": -122.50230485132435, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1ae1bbf1-459f-4346-b525-393b7d1dc958", "name": "p1rlv15599", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a779adaf-c56f-4ee1-b671-6b1ebacd5ed8"}}}}, {"uuid": "6c968024-4d09-403e-8de9-24c501753797", "name": "", "x": 38.65438386391856, "y": -122.5025685251368, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e67d2b31-f05a-4160-83ae-55154224a9ca", "name": "p1rdt7294lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c968024-4d09-403e-8de9-24c501753797"}}}}, {"uuid": "3a8505e3-0148-40ca-8dea-f61cc48f9601", "name": "", "x": 38.65435022729933, "y": -122.50246929784952, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "84040096-aca8-4cee-8539-83ae8f875e98", "name": "p1rdm16004", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3a8505e3-0148-40ca-8dea-f61cc48f9601"}}}}, {"uuid": "1214be7e-500a-4096-ad98-58bc00c5743b", "name": "", "x": 38.65468208995729, "y": -122.50209923605257, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "200aa7d8-0a43-4086-b0e7-f63cae75671d", "name": "p1rlv15618", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1214be7e-500a-4096-ad98-58bc00c5743b"}}}}, {"uuid": "fb368e45-5c62-4a91-958e-6df0c1eec86a", "name": "", "x": 38.653703111752435, "y": -122.50076138596326, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "381018f1-11cd-4519-ad24-d3419116ea84", "name": "p1rdm16011", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fb368e45-5c62-4a91-958e-6df0c1eec86a"}}}}, {"uuid": "eb97ab60-a0ad-46ff-81c6-1ab952ef9d01", "name": "", "x": 38.653216389940184, "y": -122.5007417792492, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "95b45d46-b7e7-46e2-98d9-5034e2fa0a17", "name": "p1rlv15604", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eb97ab60-a0ad-46ff-81c6-1ab952ef9d01"}}}}, {"uuid": "6432a19e-5501-4437-a6b0-cd8612d69898", "name": "", "x": 38.65369179013314, "y": -122.5008839086118, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4cee417a-3410-4907-8621-f0d3fcbc047c", "name": "p1rdt7299lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6432a19e-5501-4437-a6b0-cd8612d69898"}}}}, {"uuid": "799f4d77-24d9-4527-bf0a-c0834026128f", "name": "", "x": 38.653722262619546, "y": -122.50102558146277, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60d0a9cf-54f3-4049-9957-29839b7beb08", "name": "p1rdm16012", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "799f4d77-24d9-4527-bf0a-c0834026128f"}}}}, {"uuid": "ff26d6fb-1052-422a-81b1-50b88edd8bbd", "name": "", "x": 38.65323563888248, "y": -122.5010289572013, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "43ed408e-35e2-4bca-9060-a0c211aea1e7", "name": "p1rlv15616", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ff26d6fb-1052-422a-81b1-50b88edd8bbd"}}}}, {"uuid": "dc6d07f1-791e-4b94-9a88-dbf295621c02", "name": "", "x": 38.65171836396122, "y": -122.5073219402769, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "135a6a49-6562-4c6e-a41f-f5f78c0ac3e6", "name": "p1rdt7300lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dc6d07f1-791e-4b94-9a88-dbf295621c02"}}}}, {"uuid": "d1113cbb-086c-48b3-8046-8852b680c9f0", "name": "", "x": 38.65167635588258, "y": -122.5073274367839, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dcbee2ff-bf73-4834-bc3c-46fa0cfcad7c", "name": "p1rlv15605", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1113cbb-086c-48b3-8046-8852b680c9f0"}}}}, {"uuid": "dd0c9180-337b-4bc7-a31a-2e7577171c37", "name": "", "x": 38.65243771052424, "y": -122.50266243015153, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7cbc8145-b198-46f1-a3fd-55a05637e618", "name": "p1rdt7303lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dd0c9180-337b-4bc7-a31a-2e7577171c37"}}}}, {"uuid": "73ce9fe1-705c-4d8e-80a9-5002c8210d4b", "name": "", "x": 38.65185163082318, "y": -122.5019234602924, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "13d6bce6-9066-43a1-b2b6-00a2a4398958", "name": "p1rlv15608", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "73ce9fe1-705c-4d8e-80a9-5002c8210d4b"}}}}, {"uuid": "c3756008-99bf-4ec0-be53-adb1369cb151", "name": "", "x": 38.65403878438859, "y": -122.50195031171204, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f5094655-6494-44a9-b0ff-c5b418dcc11e", "name": "p1rdt7308lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c3756008-99bf-4ec0-be53-adb1369cb151"}}}}, {"uuid": "381a41d9-1504-45db-8a4a-b27efaca3000", "name": "", "x": 38.65437369075951, "y": -122.50163017248886, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "905a4857-5d3d-4e51-9ab0-70d634170f92", "name": "p1rlv15619", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "381a41d9-1504-45db-8a4a-b27efaca3000"}}}}, {"uuid": "4fbcffd8-86e8-496d-a8d0-357e53dacafa", "name": "", "x": 38.65414032051154, "y": -122.50185014901611, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4363602a-eb9c-41b8-8130-7bb839f4eb5a", "name": "p1rlv15641", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4fbcffd8-86e8-496d-a8d0-357e53dacafa"}}}}, {"uuid": "8d28b870-3e9d-4d30-9b6a-31be9b81e034", "name": "", "x": 38.65415951784417, "y": -122.50212583870878, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2fba947f-089b-47f3-8720-e8f3e35c097c", "name": "p1rdm16029", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8d28b870-3e9d-4d30-9b6a-31be9b81e034"}}}}, {"uuid": "6011a0aa-03d4-41bc-9cd5-35dc2c621d40", "name": "", "x": 38.65402792759886, "y": -122.50230311224807, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "13f790a1-18c0-498f-8525-fbaf0350947b", "name": "p1rlv15623", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6011a0aa-03d4-41bc-9cd5-35dc2c621d40"}}}}, {"uuid": "7bcce16d-87e0-4d10-8d57-fc5b8f524a87", "name": "", "x": 38.65396880738655, "y": -122.5017823813949, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "154999cc-f6d5-458a-8504-e4692344d372", "name": "p1rdm16030", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7bcce16d-87e0-4d10-8d57-fc5b8f524a87"}}}}, {"uuid": "ced6ff7a-a03f-4dbf-af5e-aade5a1de2b0", "name": "", "x": 38.654067738651435, "y": -122.50173572574505, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bb08eda2-b277-4bfd-9ea0-9c36765400bd", "name": "p1rlv15625", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ced6ff7a-a03f-4dbf-af5e-aade5a1de2b0"}}}}, {"uuid": "ada35336-5f78-4415-b3ea-9cc7c7352964", "name": "", "x": 38.65379214946685, "y": -122.49984533771044, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a289e26d-2d86-4fdf-942b-881b91ca18eb", "name": "p1rdt7316lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ada35336-5f78-4415-b3ea-9cc7c7352964"}}}}, {"uuid": "f1c90b98-2c9f-413b-b598-8e9a43a467cb", "name": "", "x": 38.653302578004016, "y": -122.49982178319588, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ccbef4c-6bf7-4892-a3b9-b51aca495137", "name": "p1rlv15632", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f1c90b98-2c9f-413b-b598-8e9a43a467cb"}}}}, {"uuid": "9249d58e-8a76-44e5-ab7a-bbf6e295e37f", "name": "", "x": 38.65235598284797, "y": -122.5051810906482, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16c465cf-c4ae-4702-ba6c-0b7704eda764", "name": "p1rdt7317lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9249d58e-8a76-44e5-ab7a-bbf6e295e37f"}}}}, {"uuid": "4cde1297-67a1-4116-829e-576e190346d1", "name": "", "x": 38.65233001653422, "y": -122.50513844857348, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ce7b60c8-43ee-441d-9f18-5b2722dcc0a7", "name": "p1rlv15633", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4cde1297-67a1-4116-829e-576e190346d1"}}}}, {"uuid": "36a11850-ce0c-4dc2-9025-e1a728e855f8", "name": "", "x": 38.65388017043282, "y": -122.50146517734701, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c855f7bb-1f33-4c3e-9deb-e3f9c5aba07d", "name": "p1rdt7321lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "36a11850-ce0c-4dc2-9025-e1a728e855f8"}}}}, {"uuid": "70d3109c-f76c-4c96-a280-3e806f70f125", "name": "", "x": 38.654218486038864, "y": -122.50116005048001, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "83c2de51-1b04-483c-8ce7-14b9e5e027b9", "name": "p1rlv15640", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "70d3109c-f76c-4c96-a280-3e806f70f125"}}}}, {"uuid": "540b9bcf-c9d5-4cb2-8966-7c8b6f1c4e02", "name": "", "x": 38.65226101532919, "y": -122.47461094321253, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35be767a-53a1-4fe1-b320-9542dd859d97", "name": "p1rdt7737lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "540b9bcf-c9d5-4cb2-8966-7c8b6f1c4e02"}}}}, {"uuid": "9128b7b1-69e3-423d-ab24-0b8fb59a92b2", "name": "", "x": 38.652194262671, "y": -122.47453893224326, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f5f1e7aa-d93a-4164-8bc0-f920259304a8", "name": "p1rlv16450", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9128b7b1-69e3-423d-ab24-0b8fb59a92b2"}}}}, {"uuid": "45717d17-588c-4eb9-a4be-b1c9e571652a", "name": "", "x": 38.65248920521251, "y": -122.47462474258207, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d9c505d7-3fb9-4eb5-89c6-c9c8da32fd05", "name": "p1rlv16463", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "45717d17-588c-4eb9-a4be-b1c9e571652a"}}}}, {"uuid": "0576c8e0-7b96-4420-b9f8-447650c20d43", "name": "", "x": 38.652235798683144, "y": -122.47438525528987, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "27afe70a-9123-4b0c-9f50-b5355aafcf7a", "name": "p1rlv16507", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0576c8e0-7b96-4420-b9f8-447650c20d43"}}}}, {"uuid": "ea134be6-84da-486d-a0fb-15deb4c9bca9", "name": "", "x": 38.652238275903315, "y": -122.4749368672296, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "344c6b21-94c9-4912-a19e-69fbae5eed27", "name": "p1rlv16584", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea134be6-84da-486d-a0fb-15deb4c9bca9"}}}}, {"uuid": "82e95af2-0e57-4cfe-9c63-c699df52bc84", "name": "", "x": 38.65261600612352, "y": -122.47400628819638, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c7482f0c-eb85-4e30-a09a-eb9f15bbc22b", "name": "p1rdt7753lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "82e95af2-0e57-4cfe-9c63-c699df52bc84"}}}}, {"uuid": "f0d43a70-8ec5-408b-bb0e-9092293d6456", "name": "", "x": 38.652627105759464, "y": -122.4739541259785, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d400b1b2-8404-4b80-b110-6f96e000314f", "name": "p1rlv16475", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f0d43a70-8ec5-408b-bb0e-9092293d6456"}}}}, {"uuid": "83cbec58-3089-49b8-91b1-3572e4a05cab", "name": "", "x": 38.658298169770895, "y": -122.47497347035102, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d343e634-0936-4f21-9e2c-079e19f0dfa1", "name": "p1rdt7757lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "83cbec58-3089-49b8-91b1-3572e4a05cab"}}}}, {"uuid": "b74099d8-228c-463c-a617-41b1b8d455ef", "name": "", "x": 38.65825842964543, "y": -122.47499635592735, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fa6db7ee-126d-4aa9-9733-35ff1c1d5992", "name": "p1rlv16483", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b74099d8-228c-463c-a617-41b1b8d455ef"}}}}, {"uuid": "05f73af5-dbf7-4f27-99c1-3a2dcde31799", "name": "", "x": 38.65819457523532, "y": -122.47482442341177, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0333a34b-4027-4d9a-9d4a-f867c8a317bc", "name": "p1rlv16530", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "05f73af5-dbf7-4f27-99c1-3a2dcde31799"}}}}, {"uuid": "9256eb4c-375b-42f1-8ad0-bcc74e8ae8d9", "name": "", "x": 38.658358587646056, "y": -122.4752254901639, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2f7be042-6681-4694-872d-a1cb701016c7", "name": "p1rlv16541", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9256eb4c-375b-42f1-8ad0-bcc74e8ae8d9"}}}}, {"uuid": "55908553-18e6-47d5-8215-e9cf09c30dea", "name": "", "x": 38.65188446678294, "y": -122.47516262760837, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "28e5f84f-2fac-4b5c-a669-b16988e4d6ae", "name": "p1rdt7791lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "55908553-18e6-47d5-8215-e9cf09c30dea"}}}}, {"uuid": "3e84f813-0859-4f02-bd54-f544f2df4bd7", "name": "", "x": 38.65192675650909, "y": -122.47516097998692, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "90d9dbe9-f9c9-4a4e-8ada-cb459778687b", "name": "p1rlv16573", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e84f813-0859-4f02-bd54-f544f2df4bd7"}}}}, {"uuid": "04928077-4f80-411d-97b8-360cb32be1a4", "name": "", "x": 38.65926840087407, "y": -122.47227383933975, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3959f944-18f5-4daa-a454-3c6bfb7158ff", "name": "p1rdt7795lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "04928077-4f80-411d-97b8-360cb32be1a4"}}}}, {"uuid": "1c69b90b-d0e1-4028-b482-1ca4036e8cc5", "name": "", "x": 38.659242422649335, "y": -122.47223120521224, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4f9ecb3f-8b64-4598-a9d1-d794c6800d33", "name": "p1rlv16604", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1c69b90b-d0e1-4028-b482-1ca4036e8cc5"}}}}, {"uuid": "3a49aadf-859f-4e49-b74b-d23355a7ffe5", "name": "", "x": 38.65559599442719, "y": -122.48692988350368, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b2ec0ba-a854-4631-b97a-4674123d6fe6", "name": "p1rdt8105lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3a49aadf-859f-4e49-b74b-d23355a7ffe5"}}}}, {"uuid": "4ed7c063-ce74-4874-bf3b-1cec6aacd6f6", "name": "", "x": 38.65559859235702, "y": -122.4868763747223, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ba567aae-a893-41d3-8fd1-8357d3cab35d", "name": "p1rlv17239", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ed7c063-ce74-4874-bf3b-1cec6aacd6f6"}}}}, {"uuid": "8ded3db0-024b-49be-9acc-a695799cecde", "name": "", "x": 38.65564415406407, "y": -122.48699097808593, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ac80cbea-e10a-491a-ba36-06e9fcf74217", "name": "p1rlv17280", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8ded3db0-024b-49be-9acc-a695799cecde"}}}}, {"uuid": "e0f12590-98d4-4ed7-88fc-5fa5e8fe6dff", "name": "", "x": 38.65331243461887, "y": -122.48752476984971, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d3a01639-0851-466b-abc6-adf52342e772", "name": "p1rdm17827", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e0f12590-98d4-4ed7-88fc-5fa5e8fe6dff"}}}}, {"uuid": "e1d2445b-e46e-4799-9c98-9252d8c2b600", "name": "", "x": 38.652961085543296, "y": -122.48755025792832, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "acfdbe95-2d82-463a-9d1f-6fd2688adf16", "name": "p1rlv17246", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e1d2445b-e46e-4799-9c98-9252d8c2b600"}}}}, {"uuid": "1bb45f7b-4b3a-4a44-9f4d-3048f9a15419", "name": "", "x": 38.65328712796407, "y": -122.48771232590543, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b639e55-2e33-4582-bb96-06a9d33a3419", "name": "p1rdt8111lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1bb45f7b-4b3a-4a44-9f4d-3048f9a15419"}}}}, {"uuid": "7da01a9e-f940-4a01-ac34-2a764e845b0c", "name": "", "x": 38.653333923034495, "y": -122.48782204194723, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5f70da59-a879-487b-802e-6b7158e425ca", "name": "p1rdm17828", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7da01a9e-f940-4a01-ac34-2a764e845b0c"}}}}, {"uuid": "a34da1cb-8ad8-4e47-b317-055a6b86c735", "name": "", "x": 38.65282666757047, "y": -122.4877236014364, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "04eb7e32-e372-4cb0-94a7-ee418f400bda", "name": "p1rlv17303", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a34da1cb-8ad8-4e47-b317-055a6b86c735"}}}}, {"uuid": "494046db-61b9-449a-9a55-d9608b0d5234", "name": "", "x": 38.65208064789989, "y": -122.48678276121687, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dca9b40e-ed8a-4f75-a703-91539f6c3075", "name": "p1rdt8138lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "494046db-61b9-449a-9a55-d9608b0d5234"}}}}, {"uuid": "7c64b2fd-a133-4a8c-9fcb-743e9393fa45", "name": "", "x": 38.65203864087114, "y": -122.4867882697381, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "04388b89-16fc-40b3-a060-5bc52032874e", "name": "p1rlv17291", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7c64b2fd-a133-4a8c-9fcb-743e9393fa45"}}}}, {"uuid": "1088c6d5-a0f6-4aec-b76a-562b554e8ef7", "name": "", "x": 38.65325699793473, "y": -122.48785970145335, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2bee3961-990e-47ac-b49b-d305f8fe0af8", "name": "p1rdt8146lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1088c6d5-a0f6-4aec-b76a-562b554e8ef7"}}}}, {"uuid": "56ebb882-ddef-4c87-b835-7a021bf78079", "name": "", "x": 38.65356656926306, "y": -122.48793668955402, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "84ebd9bb-dc50-483d-a3c6-044682d4020c", "name": "p1rlv17311", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "56ebb882-ddef-4c87-b835-7a021bf78079"}}}}, {"uuid": "c69bb444-8523-4fdb-99e3-e8c089f4c256", "name": "", "x": 38.66673594751398, "y": -122.46980033939064, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa", "name": "p1rdt8167lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c69bb444-8523-4fdb-99e3-e8c089f4c256"}}}}, {"uuid": "b5629075-98c4-481e-8592-5d57793c505c", "name": "", "x": 38.66651447553529, "y": -122.46928074240148, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8ead5953-70f2-4db2-ba4d-d203c91d85c1", "name": "p1rlv17345", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b5629075-98c4-481e-8592-5d57793c505c"}}}}, {"uuid": "098d3ef0-d2ce-45d0-b04b-b6fa2a56d0b0", "name": "", "x": 38.66618245827339, "y": -122.4695935453166, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf6f74e5-7aa3-4333-bd37-3ce486d54a01", "name": "p1rlv17357", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "098d3ef0-d2ce-45d0-b04b-b6fa2a56d0b0"}}}}, {"uuid": "688ea7b2-7e09-464c-9685-92079311bc8a", "name": "", "x": 38.6673297300225, "y": -122.47020579507135, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d38cdffb-41be-48aa-8a03-c6525dd01037", "name": "p1rlv17397", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "688ea7b2-7e09-464c-9685-92079311bc8a"}}}}, {"uuid": "3dc7dadf-fb8b-4fe0-bf61-9116073c4629", "name": "", "x": 38.66639617857814, "y": -122.46902873548488, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "63177299-2842-4e0d-bf17-7bd2b0afe9a2", "name": "p1rlv17400", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3dc7dadf-fb8b-4fe0-bf61-9116073c4629"}}}}, {"uuid": "ad90541b-98b5-45cd-aea6-3f4573d2327e", "name": "", "x": 38.66678976962103, "y": -122.47037069875277, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b50de14e-9a09-4f61-8998-0979f33b0d0a", "name": "p1rlv17405", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ad90541b-98b5-45cd-aea6-3f4573d2327e"}}}}, {"uuid": "43488034-d332-485e-b8da-3a24da45e181", "name": "", "x": 38.66709595196411, "y": -122.47032246448548, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "86b2527b-73c3-41c4-8ac2-7cb0e8bc2a7a", "name": "p1rlv17415", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "43488034-d332-485e-b8da-3a24da45e181"}}}}, {"uuid": "ff26a39a-d362-48b4-b352-4a4d2839995a", "name": "", "x": 38.66477303429095, "y": -122.46767335323095, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6349165a-d47a-4cf4-84f9-df5c5f3a0e98", "name": "p1rdt8169lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ff26a39a-d362-48b4-b352-4a4d2839995a"}}}}, {"uuid": "443ccb79-9a64-4ac3-b93f-fa60e82b93dd", "name": "", "x": 38.66481200983204, "y": -122.467465715666, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d98640c6-d8aa-44e4-9ecf-5998152d3f7d", "name": "p1rlv17347", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "443ccb79-9a64-4ac3-b93f-fa60e82b93dd"}}}}, {"uuid": "f004f264-53e5-4fd1-8448-926cf4132117", "name": "", "x": 38.664771291883746, "y": -122.46842004356215, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2695decb-d268-46b2-8604-9c33dc90518b", "name": "p1rlv17351", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f004f264-53e5-4fd1-8448-926cf4132117"}}}}, {"uuid": "21b4086a-2833-4014-96f2-2209265c8dbd", "name": "", "x": 38.66479314943949, "y": -122.4672819466205, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9d61897a-cdac-4b4a-8812-8a8692a3d958", "name": "p1rlv17403", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "21b4086a-2833-4014-96f2-2209265c8dbd"}}}}, {"uuid": "f0bd1e1c-ade2-43ea-875c-2be47a63315b", "name": "", "x": 38.661451147924325, "y": -122.47380185053476, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4903e82a-8cfb-406e-b4bf-5e01068419a3", "name": "p1rdt8174lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f0bd1e1c-ade2-43ea-875c-2be47a63315b"}}}}, {"uuid": "56156265-30ca-4fec-b4a3-d59a1ce3950c", "name": "", "x": 38.66119075710339, "y": -122.4737681067613, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f34e3e4e-bebd-4148-bcc7-cbfbecd73a2f", "name": "p1rlv17353", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "56156265-30ca-4fec-b4a3-d59a1ce3950c"}}}}, {"uuid": "8e5ea8b0-2606-496e-b62b-336950b8c3ad", "name": "", "x": 38.66166044070652, "y": -122.47400603929611, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "08709e25-b030-4801-ae00-c4879556d8b1", "name": "p1rlv17378", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8e5ea8b0-2606-496e-b62b-336950b8c3ad"}}}}, {"uuid": "20ce5bab-71b6-436d-abd2-2689fe8b4c7c", "name": "", "x": 38.66156929181106, "y": -122.47377683037024, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e1ad135-904d-47ed-ae74-32b38e1c2f88", "name": "p1rlv17383", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "20ce5bab-71b6-436d-abd2-2689fe8b4c7c"}}}}, {"uuid": "b0fbd10a-9771-4bd7-8373-783698ea0919", "name": "", "x": 38.66528062582966, "y": -122.47017186379257, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e8e03b63-853e-4cfe-bf4a-3779b2026637", "name": "p1rdt8180lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b0fbd10a-9771-4bd7-8373-783698ea0919"}}}}, {"uuid": "51433068-e7bc-4d85-ab18-651de34b6f21", "name": "", "x": 38.665280591504875, "y": -122.4701179030113, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c705333f-6f1a-4a76-a02e-eaa859e99b70", "name": "p1rlv17361", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "51433068-e7bc-4d85-ab18-651de34b6f21"}}}}, {"uuid": "689be9de-1a3d-4405-9fc9-4e242c05dec8", "name": "", "x": 38.66045657865189, "y": -122.47345917790395, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "782d6008-7fec-46b6-9461-9e33b79539d3", "name": "p1rdt8195lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "689be9de-1a3d-4405-9fc9-4e242c05dec8"}}}}, {"uuid": "cb0259a5-54e7-49a0-9eda-41e167976f9b", "name": "", "x": 38.66053224527863, "y": -122.47362350869747, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e835b413-3307-49ef-ad69-cf18a5ae7cfb", "name": "p1rlv17385", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb0259a5-54e7-49a0-9eda-41e167976f9b"}}}}, {"uuid": "1a251dab-2e8e-4c18-aeec-e3ad49945911", "name": "", "x": 38.660557365368454, "y": -122.47319806082461, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "55382019-a1a5-40fd-b90a-072af40c2258", "name": "p1rlv17387", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1a251dab-2e8e-4c18-aeec-e3ad49945911"}}}}, {"uuid": "2a87817d-94cb-4638-8c68-d8fc549cb84a", "name": "", "x": 38.66087354418496, "y": -122.47336814960953, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "169a22de-bb0a-4056-8910-151125c4ff9e", "name": "p1rlv17391", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2a87817d-94cb-4638-8c68-d8fc549cb84a"}}}}, {"uuid": "7e225669-7357-4c5f-a6b8-e6c959f1a8d3", "name": "", "x": 38.66027039448875, "y": -122.47351048965503, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "65de341c-589f-4bf9-a708-26fcc94a6c0a", "name": "p1rlv17407", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7e225669-7357-4c5f-a6b8-e6c959f1a8d3"}}}}, {"uuid": "b9619af0-f534-4ed8-b443-1108e70cd926", "name": "", "x": 38.66016282543937, "y": -122.47363770635508, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "67003f0f-6690-469e-82c0-63949ee5241e", "name": "p1rlv17417", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b9619af0-f534-4ed8-b443-1108e70cd926"}}}}, {"uuid": "1d442fee-a8d8-44b1-b273-76993ff7d240", "name": "", "x": 38.66642010101456, "y": -122.47095566992769, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "76e33e4f-05be-44d1-a503-fed82b4da974", "name": "p1rdt8201lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d442fee-a8d8-44b1-b273-76993ff7d240"}}}}, {"uuid": "fb83ab4d-1060-4dd9-9f30-4b8f22cb1510", "name": "", "x": 38.66660266134409, "y": -122.47084335519723, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ea560bcb-f930-4f42-ae45-3a60f36fdbb7", "name": "p1rlv17394", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fb83ab4d-1060-4dd9-9f30-4b8f22cb1510"}}}}, {"uuid": "48c5cddc-037d-4d5b-b65a-c400b0f007e8", "name": "", "x": 38.66627923556136, "y": -122.47106413182223, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "64a56527-23a9-4229-aa25-f6a45f2187f4", "name": "p1rlv17416", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "48c5cddc-037d-4d5b-b65a-c400b0f007e8"}}}}, {"uuid": "cb371e53-908c-4a9f-a2b4-4fac71dc0dec", "name": "", "x": 38.658114052272616, "y": -122.48189066352298, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8c1f6cd8-cde1-45cc-87ca-1355efa38077", "name": "p1rdt9055lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb371e53-908c-4a9f-a2b4-4fac71dc0dec"}}}}, {"uuid": "76473ac2-56a8-4fac-a4da-1dbaf863b311", "name": "", "x": 38.658139573766896, "y": -122.48184758396665, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be1b9922-2426-4726-9e5a-bcd33f444b57", "name": "p1rlv19616", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "76473ac2-56a8-4fac-a4da-1dbaf863b311"}}}}, {"uuid": "4dc345dd-f015-495c-886a-f88a38d01b1d", "name": "", "x": 38.65791058099435, "y": -122.46275595471984, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "afb4c195-8bb6-47d5-88f3-76adb9cda250", "name": "p1rdt9086lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4dc345dd-f015-495c-886a-f88a38d01b1d"}}}}, {"uuid": "9c47b247-8e1b-4242-9fa7-3d602fc71749", "name": "", "x": 38.657936095394604, "y": -122.46271286857773, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "19894180-0890-4585-b4e2-55500af3c41a", "name": "p1rlv19683", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9c47b247-8e1b-4242-9fa7-3d602fc71749"}}}}, {"uuid": "78134a20-f557-4c7c-bdfc-f58d76af56d2", "name": "", "x": 38.69033987948928, "y": -122.31517238474055, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "40b03cbe-470d-493a-854a-900557ac20c8", "name": "p1rdt16394lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "78134a20-f557-4c7c-bdfc-f58d76af56d2"}}}}, {"uuid": "c5989fcd-1f6f-4491-88d2-00fe769d047a", "name": "", "x": 38.690138170140635, "y": -122.31563821475763, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f827fe9e-1ffe-456c-a57b-c3374aef8ad8", "name": "p1rlv37689", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c5989fcd-1f6f-4491-88d2-00fe769d047a"}}}}, {"uuid": "f89b95b1-f645-487d-b039-3554fc023a6f", "name": "", "x": 38.69038758916915, "y": -122.3151414107498, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "da3cd593-6f05-41ba-9609-f6f1e307e998", "name": "p1rlv37691", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f89b95b1-f645-487d-b039-3554fc023a6f"}}}}, {"uuid": "c45145a7-e48a-45a9-b733-91ed9471b83f", "name": "", "x": 38.690565522935835, "y": -122.31474877047064, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "01c9efda-0adf-4932-8f54-2938964371d2", "name": "p1rlv37703", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c45145a7-e48a-45a9-b733-91ed9471b83f"}}}}, {"uuid": "065fe856-5120-4d7c-96e9-00c8304e4ee3", "name": "", "x": 38.68956634076771, "y": -122.30929268806497, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "38b0bd7c-0898-497f-bb24-4add0fd92932", "name": "p1rdt16404lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "065fe856-5120-4d7c-96e9-00c8304e4ee3"}}}}, {"uuid": "f48745c0-959b-4078-b13d-3e5d27fd30a0", "name": "", "x": 38.68932901734512, "y": -122.30982786050683, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "38bda697-2888-467e-bab0-62896a62503f", "name": "p1rlv37710", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f48745c0-959b-4078-b13d-3e5d27fd30a0"}}}}, {"uuid": "a534a629-8809-4af4-8251-f12881581d93", "name": "", "x": 38.68985442947351, "y": -122.30876497515673, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f8d998a0-628e-4009-a6c8-07af906f6d43", "name": "p1rlv37732", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a534a629-8809-4af4-8251-f12881581d93"}}}}, {"uuid": "f671dd9e-c96a-4c72-a7f2-32b8324f73df", "name": "", "x": 38.71319629081823, "y": -122.2618537891679, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "58dce206-0571-4a37-b24b-2e674e0c0d3b", "name": "p1rdm37174", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f671dd9e-c96a-4c72-a7f2-32b8324f73df"}}}}, {"uuid": "3dc216d4-8c44-41bb-a2eb-0d33315315ef", "name": "", "x": 38.713341484062944, "y": -122.26201332345111, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b24da1e-9a6e-4545-9ad4-a9f0e9675fd1", "name": "p1rlv37776", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3dc216d4-8c44-41bb-a2eb-0d33315315ef"}}}}, {"uuid": "0344c586-dfad-4b14-85d0-f6ac8106e33a", "name": "", "x": 38.71333206265715, "y": -122.26149980897426, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "23775c66-0b90-443d-8566-491405876e9d", "name": "p1rdt16424lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0344c586-dfad-4b14-85d0-f6ac8106e33a"}}}}, {"uuid": "990f60d2-63fa-4bd2-86bb-fd9b7e60eaad", "name": "", "x": 38.713372298566235, "y": -122.26118486465606, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d21a9584-0fe7-48a6-a46e-ac33e948a471", "name": "p1rdm37175", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "990f60d2-63fa-4bd2-86bb-fd9b7e60eaad"}}}}, {"uuid": "f5b8af75-ea5b-40bf-ba70-84760d41fac7", "name": "", "x": 38.71352621311042, "y": -122.26129830022444, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f5aaed5d-8312-4707-a047-634e433bf49f", "name": "p1rlv37778", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5b8af75-ea5b-40bf-ba70-84760d41fac7"}}}}, {"uuid": "72f2febe-f3c7-4987-8225-28831e04951b", "name": "", "x": 38.71269200809747, "y": -122.26236108033618, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "980376ed-54fd-434c-b58e-0bbd6eaa9954", "name": "p1rdt16427lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "72f2febe-f3c7-4987-8225-28831e04951b"}}}}, {"uuid": "16355f17-6818-4e54-8516-4c17b62d5f1e", "name": "", "x": 38.71269522836307, "y": -122.26242253360313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0d7181ee-ef64-4ded-b619-00ac09d55bf5", "name": "p1rlv37782", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "16355f17-6818-4e54-8516-4c17b62d5f1e"}}}}, {"uuid": "ba848da2-4966-44bb-878b-7dc0e31f2430", "name": "", "x": 38.684304380145115, "y": -122.31768680277943, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "26bc650a-6838-4320-8afa-b8d2f22e96e8", "name": "p1rdt16603lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ba848da2-4966-44bb-878b-7dc0e31f2430"}}}}, {"uuid": "dcfb8e68-db83-4b06-a59d-4820b9154406", "name": "", "x": 38.68458254841867, "y": -122.31796762036473, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "10be49a0-301a-4c7e-8ab7-49c14e483079", "name": "p1rlv38046", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dcfb8e68-db83-4b06-a59d-4820b9154406"}}}}, {"uuid": "bb368911-48db-4b83-b838-5c483aa7c0a3", "name": "", "x": 38.68382003837408, "y": -122.31702058531167, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0935a86b-b9fb-4058-8381-a41f67d6c9dd", "name": "p1rlv38047", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bb368911-48db-4b83-b838-5c483aa7c0a3"}}}}, {"uuid": "fd245f8b-6db6-41f1-b94c-9b6191e22523", "name": "", "x": 38.684447916688484, "y": -122.31806087736241, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9db6122d-1e51-46ac-9cea-ac436e189cd8", "name": "p1rlv38052", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fd245f8b-6db6-41f1-b94c-9b6191e22523"}}}}, {"uuid": "867a88ab-030c-47f8-8e55-ba767e4fd31c", "name": "", "x": 38.68318595308261, "y": -122.31906558684712, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d31da07-e20a-4fb8-95f4-d91450395471", "name": "p1rdt16604lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "867a88ab-030c-47f8-8e55-ba767e4fd31c"}}}}, {"uuid": "a92bf90f-f106-4803-b7cd-a94b7ec6a0e7", "name": "", "x": 38.68325558877688, "y": -122.31912993455164, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5da7ff68-5f4c-4d56-88fc-7736df03c0bf", "name": "p1rlv38048", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a92bf90f-f106-4803-b7cd-a94b7ec6a0e7"}}}}, {"uuid": "1be34c71-cd62-4229-a445-4640d75a7920", "name": "", "x": 38.683074628268045, "y": -122.31900518071453, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cafc6c03-240d-499d-a3d8-983b554dd007", "name": "p1rlv38050", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1be34c71-cd62-4229-a445-4640d75a7920"}}}}, {"uuid": "85f3f994-ebf6-4123-8306-7c66f4fe90fe", "name": "", "x": 38.72488522966494, "y": -122.31175617505791, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a4a3b828-bddf-4314-b9a5-03b9dfcd2618", "name": "p1rdt16787lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "85f3f994-ebf6-4123-8306-7c66f4fe90fe"}}}}, {"uuid": "4cb84e15-fc68-4ec5-ab40-cf063445d1c9", "name": "", "x": 38.72480906566549, "y": -122.31154585900022, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a25b3511-86cf-404e-944f-273d3f94c05a", "name": "p1rlv38414", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4cb84e15-fc68-4ec5-ab40-cf063445d1c9"}}}}, {"uuid": "a1e6aa75-b873-4007-a204-cf87e0d543ff", "name": "", "x": 38.724919569400605, "y": -122.3119474333546, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a6e4595c-0ad9-4501-b86f-c559917d4b86", "name": "p1rlv38419", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a1e6aa75-b873-4007-a204-cf87e0d543ff"}}}}, {"uuid": "37841bc9-c1dc-4418-bcb3-7309b15e549c", "name": "", "x": 38.725467899287466, "y": -122.31258369528427, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9c261090-bc22-4d81-9a9e-75227cd7c99e", "name": "p1rdt16790lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "37841bc9-c1dc-4418-bcb3-7309b15e549c"}}}}, {"uuid": "788ddba8-11aa-4aa0-8e92-f9c2adc10b3d", "name": "", "x": 38.725441863299416, "y": -122.312541080781, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "201112bb-3dc7-4a15-9af6-155626ac1ae5", "name": "p1rlv38417", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "788ddba8-11aa-4aa0-8e92-f9c2adc10b3d"}}}}, {"uuid": "5793a67e-5c04-4b95-ba75-d4fe24c7dea9", "name": "", "x": 38.69566612075781, "y": -122.29850531296424, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e1abef1d-4ffc-4696-91ca-e81ac36cce61", "name": "p1rdt16847lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5793a67e-5c04-4b95-ba75-d4fe24c7dea9"}}}}, {"uuid": "a380a296-2b02-4d46-bfde-f814f84ed80a", "name": "", "x": 38.695297864066646, "y": -122.29823690772227, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a0764c32-4f46-473a-9a72-cccc45ae28d7", "name": "p1rlv38535", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a380a296-2b02-4d46-bfde-f814f84ed80a"}}}}, {"uuid": "14b0b62d-7296-422d-9cc1-708bd7167a8c", "name": "", "x": 38.69607606503067, "y": -122.29876976693473, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5ff930f9-63f0-4cab-b74a-3db7eb99f9eb", "name": "p1rlv38536", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "14b0b62d-7296-422d-9cc1-708bd7167a8c"}}}}, {"uuid": "4d757316-db89-48f9-b906-07965b862b6a", "name": "", "x": 38.74356263285725, "y": -122.27336627842594, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0df1550a-7e69-42e9-8059-3a36ecb3d253", "name": "p1rdt16911lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d757316-db89-48f9-b906-07965b862b6a"}}}}, {"uuid": "28b52fe4-3ee2-48fe-9797-05cbf31832d3", "name": "", "x": 38.74357721508068, "y": -122.27335107450713, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4a3851f7-2dd3-447b-918f-7a8c954f21d1", "name": "p1rlv38638", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "28b52fe4-3ee2-48fe-9797-05cbf31832d3"}}}}, {"uuid": "752654c3-b2fa-4808-8238-2c2cfff7aadc", "name": "", "x": 38.67909765473299, "y": -122.51997053087246, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d49257c8-f8eb-4024-9c02-461d18cdd3d5", "name": "p1rdt383", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "752654c3-b2fa-4808-8238-2c2cfff7aadc"}}}}, {"uuid": "46aeb7f3-d13e-4a01-8839-fdd865ccf46d", "name": "", "x": 38.67949973700607, "y": -122.52574842403467, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8d8cd980-268f-4adb-a6ee-70edf7784542", "name": "p1rdt383-p1rdt384x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "46aeb7f3-d13e-4a01-8839-fdd865ccf46d"}}}}, {"uuid": "a23443c6-1d62-4ffa-9f5b-5736dfcce6aa", "name": "", "x": 38.6790657111712, "y": -122.52914676125815, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7adf2f4b-f0fd-4c53-abcf-d90fe1a2b4c4", "name": "p1rdt384", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a23443c6-1d62-4ffa-9f5b-5736dfcce6aa"}}}}, {"uuid": "90950951-2a50-4431-b77b-57d9b3dbe8c7", "name": "", "x": 38.651801942472055, "y": -122.5073324871614, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f9240d01-bf5d-41ed-8c53-c1f04af1a236", "name": "p1rdt383-p1rdt7300x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "90950951-2a50-4431-b77b-57d9b3dbe8c7"}}}}, {"uuid": "4d44044a-2d92-4b3c-9aab-774930b93609", "name": "", "x": 38.65515241674437, "y": -122.50889970027711, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e5ac1506-77e9-4b90-ad3d-18be099063a9", "name": "p1rdt383-p1rdt7300x_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d44044a-2d92-4b3c-9aab-774930b93609"}}}}, {"uuid": "05fc9700-79a2-4dc4-bf3d-f5de2a903094", "name": "", "x": 38.653733535353965, "y": -122.50089156658129, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d065da7b-7e88-4e63-a47c-959f4d4c6e1c", "name": "p1rdt7299", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "05fc9700-79a2-4dc4-bf3d-f5de2a903094"}}}}, {"uuid": "c914feb5-e9de-422b-aeaf-cfc62dd17293", "name": "", "x": 38.65375040418197, "y": -122.49983768034305, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6322bf4d-0976-4bae-94c0-f76f83ccb9bf", "name": "p1rdt7316", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c914feb5-e9de-422b-aeaf-cfc62dd17293"}}}}, {"uuid": "ab222d15-220f-49d0-9978-7493ba856d51", "name": "", "x": 38.65383842524826, "y": -122.5014575190295, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b468be25-1324-46ab-9424-887741ca1134", "name": "p1rdt7321", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ab222d15-220f-49d0-9978-7493ba856d51"}}}}, {"uuid": "9819f669-9c19-41ec-86fe-e3a06b9a4003", "name": "", "x": 38.65408052954152, "y": -122.50195797033598, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d2e605b4-fe7a-4571-947d-8ae19de627d8", "name": "p1rdt7308", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9819f669-9c19-41ec-86fe-e3a06b9a4003"}}}}, {"uuid": "dd3454db-2254-4e87-a37a-95cfce8f56ef", "name": "", "x": 38.65442560903119, "y": -122.50257618415456, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a955da2d-e212-4026-b1fb-0021a04ded07", "name": "p1rdt7294", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dd3454db-2254-4e87-a37a-95cfce8f56ef"}}}}, {"uuid": "27154954-bf7a-47cd-b84f-cfe43e152146", "name": "", "x": 38.652479455643565, "y": -122.5026700890289, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e6f24e3a-088a-4d1b-8292-03015289d88e", "name": "p1rdt7303", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "27154954-bf7a-47cd-b84f-cfe43e152146"}}}}, {"uuid": "ac160d78-43c2-4240-98f5-e6ae472758ac", "name": "", "x": 38.652370317308936, "y": -122.50523190353242, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48efebbb-c70a-47d3-aae3-0e39088fc455", "name": "p1rdt7317", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ac160d78-43c2-4240-98f5-e6ae472758ac"}}}}, {"uuid": "03e38011-c0fb-4e11-9933-4cd3cac852ba", "name": "", "x": 38.65220758039855, "y": -122.50510436245315, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e9980c6-3edc-4b4a-be98-cec731419c30", "name": "p1rdt7303-p1rdt7317x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "03e38011-c0fb-4e11-9933-4cd3cac852ba"}}}}, {"uuid": "5860e8c6-343d-4d04-bad2-41ef009e292b", "name": "", "x": 38.65176065727734, "y": -122.50732046975546, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "05f14a3e-053e-4b65-b962-da7804b9e2c1", "name": "p1rdt7300", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5860e8c6-343d-4d04-bad2-41ef009e292b"}}}}, {"uuid": "07ba29a5-2151-46cd-a5ab-f359ec3ab19c", "name": "", "x": 38.64755417890137, "y": -122.50920989641365, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "47f8ed28-4bff-47d9-8ffe-4509e9c5b7fc", "name": "p1rdt6488-p1rdt7300x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "07ba29a5-2151-46cd-a5ab-f359ec3ab19c"}}}}, {"uuid": "2f8c22fe-e901-48d9-9eef-46f361d4dc9c", "name": "", "x": 38.64759956755727, "y": -122.50867546400877, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b96c1e20-68ac-4548-a068-86483c7fa921", "name": "p1rdt6488-p1rdt7300xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2f8c22fe-e901-48d9-9eef-46f361d4dc9c"}}}}, {"uuid": "0840458c-3040-4065-b329-753f2e9edfff", "name": "", "x": 38.659282749601154, "y": -122.47232465037078, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bee93ff6-6ff8-4572-b339-c8e897dac81b", "name": "p1rdt7795", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0840458c-3040-4065-b329-753f2e9edfff"}}}}, {"uuid": "218dc36b-329c-4f26-a80d-dc68a2c4a6cc", "name": "", "x": 38.65789678232331, "y": -122.46280701212554, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75ee3b24-7407-45ba-94d5-abe187306f13", "name": "p1rdt9086", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "218dc36b-329c-4f26-a80d-dc68a2c4a6cc"}}}}, {"uuid": "ead0976b-5a32-4ecb-90c0-3f17d38fc9bf", "name": "", "x": 38.6582588467901, "y": -122.47506760778616, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0cd22d3e-1e2a-4a99-9967-b9df95837915", "name": "p1rdt7757-p1rdt7795x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ead0976b-5a32-4ecb-90c0-3f17d38fc9bf"}}}}, {"uuid": "575a3212-4155-4852-a5f4-bb331a4bbb26", "name": "", "x": 38.66713136194248, "y": -122.47883578171474, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "53e5fee4-5a31-448e-8bd0-d8996468d085", "name": "p1rdt6261", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "575a3212-4155-4852-a5f4-bb331a4bbb26"}}}}, {"uuid": "c526aa31-5e92-4d33-af90-0c67bd587449", "name": "", "x": 38.66662516142702, "y": -122.47987793918193, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6c00c7b1-0aec-4669-9679-cbc1476e0526", "name": "p1rdt6261-p1rdt6262x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c526aa31-5e92-4d33-af90-0c67bd587449"}}}}, {"uuid": "8d4d5410-3d6d-4a36-8d81-2eb1e14929e8", "name": "", "x": 38.66651499085745, "y": -122.4800586749112, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf092ec9-ecda-4216-9ac0-0bc035973515", "name": "p1rdt6262", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8d4d5410-3d6d-4a36-8d81-2eb1e14929e8"}}}}, {"uuid": "4c9a6417-dd7e-4201-97f3-4b1de459f448", "name": "", "x": 38.666918119613086, "y": -122.48091258305858, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c61df077-693e-4e67-aea6-ee60b99406d1", "name": "p1rdt6263", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c9a6417-dd7e-4201-97f3-4b1de459f448"}}}}, {"uuid": "7ca3f583-3b6e-4756-99c2-2beee9dd510f", "name": "", "x": 38.66244739498498, "y": -122.4766461808176, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e22d08f0-2afc-426a-a0c0-6b00cc1103aa", "name": "p1rdt6266", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7ca3f583-3b6e-4756-99c2-2beee9dd510f"}}}}, {"uuid": "dfcbece4-24cf-4df0-b723-98cebf605a35", "name": "", "x": 38.663631853304395, "y": -122.47754329911722, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cab917a3-5cc2-46d5-9cee-971591841f12", "name": "p1rdt6261-p1rdt6266x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dfcbece4-24cf-4df0-b723-98cebf605a35"}}}}, {"uuid": "d4d80403-25d9-41a5-9e44-5bc2e1041169", "name": "", "x": 38.66255554922429, "y": -122.47735618000138, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4a03d20d-664a-4e80-abec-a36910787829", "name": "p1rdt6264", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d4d80403-25d9-41a5-9e44-5bc2e1041169"}}}}, {"uuid": "7f90f9c9-ada7-4545-805f-74e7ff76cce2", "name": "", "x": 38.66324435870563, "y": -122.47754611470971, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9b6508ce-e51b-4173-8b54-3f3eb7a2cd71", "name": "p1rdt6266-p1rdt6267x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7f90f9c9-ada7-4545-805f-74e7ff76cce2"}}}}, {"uuid": "edabaa6d-c4da-4492-a840-5b6a75d9064f", "name": "", "x": 38.66526274271137, "y": -122.47948778772573, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a1d9cfa7-0024-4896-a263-2715086f2ad6", "name": "p1rdt6267", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "edabaa6d-c4da-4492-a840-5b6a75d9064f"}}}}, {"uuid": "3d879b6c-dee9-4e19-a2b9-c9353631ef11", "name": "", "x": 38.66146360124312, "y": -122.4739001517938, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d07105ef-1ba3-4775-aeb4-650b5ea8736e", "name": "p1rdt6266-p1rdt8174x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3d879b6c-dee9-4e19-a2b9-c9353631ef11"}}}}, {"uuid": "fa6491bf-299d-44eb-ad2d-891e877aa105", "name": "", "x": 38.75306841044715, "y": -122.36663378364803, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "79d0fee6-369b-4f95-a2d2-cd05232652e3", "name": "p1rdt181", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa6491bf-299d-44eb-ad2d-891e877aa105"}}}}, {"uuid": "c072f967-5c31-42c3-8e9b-35184b126f3f", "name": "", "x": 38.754868310420626, "y": -122.36837472635783, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "24681ab1-3904-4509-85e6-d9bb1dba4c8e", "name": "p1rdt181_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c072f967-5c31-42c3-8e9b-35184b126f3f"}}}}, {"uuid": "2ad22731-6846-4b63-baa9-765766802509", "name": "", "x": 38.771927561946114, "y": -122.36440291040475, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0d4e6a87-0313-419f-8feb-7ea3a29f59ae", "name": "p1rdt275", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2ad22731-6846-4b63-baa9-765766802509"}}}}, {"uuid": "665fada7-7a88-4136-9eab-40f5c884f0b2", "name": "", "x": 38.78773053668457, "y": -122.34702184190017, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1a85646-be2b-4b15-9c2f-cc603c7e06df", "name": "p1rdt253", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "665fada7-7a88-4136-9eab-40f5c884f0b2"}}}}, {"uuid": "b4b135e0-c9a9-4999-9448-44a19e6f2767", "name": "", "x": 38.76715093535089, "y": -122.36057334237034, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eb9e5f0f-8bcf-4019-a786-3f24334e9ae7", "name": "p1rdt68", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b4b135e0-c9a9-4999-9448-44a19e6f2767"}}}}, {"uuid": "32e939e4-5261-4ed7-9bef-2dc70b0e4447", "name": "", "x": 38.77038045634796, "y": -122.36232121374398, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8435bee2-05ea-4208-9520-809129624d70", "name": "p1rdt275-p1rdt68x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "32e939e4-5261-4ed7-9bef-2dc70b0e4447"}}}}, {"uuid": "54cceeea-9aa0-4d66-8115-b4b848862660", "name": "", "x": 38.762804233208215, "y": -122.3567217728313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e9cb7919-b8bd-46c1-a173-90a5d241c46e", "name": "p1rdt280", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "54cceeea-9aa0-4d66-8115-b4b848862660"}}}}, {"uuid": "8845fc18-33d7-47e8-a26b-2bf3b16d7ee2", "name": "", "x": 38.754224477281774, "y": -122.36483177825646, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ac745c6f-6e78-4a68-affa-649f91d3aa7c", "name": "p1rdt281", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8845fc18-33d7-47e8-a26b-2bf3b16d7ee2"}}}}, {"uuid": "cd2affdb-33a9-4f80-bda0-c84fa9ffaa09", "name": "", "x": 38.762332092473166, "y": -122.35720189679247, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4425707e-f2b0-419f-828e-a4642ee34b5a", "name": "p1rdt280-p1rdt281x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cd2affdb-33a9-4f80-bda0-c84fa9ffaa09"}}}}, {"uuid": "d1a7b63c-63eb-4950-aaa9-c61ee1ba140b", "name": "", "x": 38.72318515388558, "y": -122.41088395202819, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2fddf29e-6eef-4c60-ad8b-4580440973b3", "name": "p1rdt181-p1rdt297x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1a7b63c-63eb-4950-aaa9-c61ee1ba140b"}}}}, {"uuid": "851a2f84-14c6-409d-8071-4667378696d9", "name": "", "x": 38.726937156537616, "y": -122.40539968889463, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d87f56c0-0a3f-4a94-8f60-1ece461290d0", "name": "p1rdt181-p1rdt297x_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "851a2f84-14c6-409d-8071-4667378696d9"}}}}, {"uuid": "759e1907-5ba4-48d6-919d-b558f46832b1", "name": "", "x": 38.759945311222936, "y": -122.44222861124264, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "170a2bcb-d7ce-4617-855b-9111b84262ed", "name": "p1rdt3776", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "759e1907-5ba4-48d6-919d-b558f46832b1"}}}}, {"uuid": "7668d332-5379-4200-a145-37c5d95aa7ac", "name": "", "x": 38.75895331123435, "y": -122.44467277060775, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5f9af980-79c4-4daf-b8fc-44e02953f98b", "name": "p1rdt3777", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7668d332-5379-4200-a145-37c5d95aa7ac"}}}}, {"uuid": "02b963dd-7858-4cea-b384-6910759c8ab5", "name": "", "x": 38.7505314706947, "y": -122.41545810153862, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7eca59ac-01f1-40d7-a0ec-51f355285e01", "name": "p1rdt270", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "02b963dd-7858-4cea-b384-6910759c8ab5"}}}}, {"uuid": "0006edd5-9a24-4cdf-8952-aeacecc849f2", "name": "", "x": 38.75941275867633, "y": -122.44145409385084, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6168ebbc-8fd5-49a0-94db-887814eceaba", "name": "p1rdt270-p1rdt3776x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0006edd5-9a24-4cdf-8952-aeacecc849f2"}}}}, {"uuid": "27c267c2-ebc5-4f52-93a6-6ee6fa420984", "name": "", "x": 38.724404971590296, "y": -122.41244167570912, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e2c76250-d7ea-4da4-8008-dac1a579e974", "name": "p1rdt270-p1rdt298x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "27c267c2-ebc5-4f52-93a6-6ee6fa420984"}}}}, {"uuid": "b13b2b3e-f03d-40da-ab3d-d9146809b14f", "name": "", "x": 38.72936375125469, "y": -122.41301863676793, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ac7c613f-190c-493e-8e89-3ef48e8efdb9", "name": "p1rdt270-p1rdt298x_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b13b2b3e-f03d-40da-ab3d-d9146809b14f"}}}}, {"uuid": "f23ba844-eefe-4850-91bd-642274b7cd43", "name": "", "x": 38.72321115431449, "y": -122.41092660136522, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d32493ec-06be-48ef-959e-779c79c507a3", "name": "p1rdt297", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f23ba844-eefe-4850-91bd-642274b7cd43"}}}}, {"uuid": "f64c9648-faca-44e7-8a97-9c3c8dc95507", "name": "", "x": 38.72444619013448, "y": -122.4124539994752, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7a468f13-c61f-4c01-aa27-c75fb02030e0", "name": "p1rdt298", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f64c9648-faca-44e7-8a97-9c3c8dc95507"}}}}, {"uuid": "546b8fad-55ef-4415-a10c-2b3d67c1758c", "name": "", "x": 38.716932571899626, "y": -122.4194260124673, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "91f76b91-e00a-4a88-8ee8-ec403c2c7d96", "name": "p1rdt385", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "546b8fad-55ef-4415-a10c-2b3d67c1758c"}}}}, {"uuid": "5c83ea19-2401-4a56-b711-6b8cc4186995", "name": "", "x": 38.70723340886135, "y": -122.42474689668317, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "22179eaa-fd19-4619-8b31-52bcb36ec683", "name": "p1rdt252-p1rdt385x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5c83ea19-2401-4a56-b711-6b8cc4186995"}}}}, {"uuid": "215d5350-57f3-47a2-ad91-9221da3b8bdc", "name": "", "x": 38.7068487847659, "y": -122.42495904757907, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f9c899bc-796a-4e92-88db-6aa11f8777cb", "name": "p1rdt251-p1rdt254x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "215d5350-57f3-47a2-ad91-9221da3b8bdc"}}}}, {"uuid": "ef1d5226-a8f9-4454-a993-7cb000b03794", "name": "", "x": 38.706847489569306, "y": -122.42594987463313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ab802e3-3a0a-413c-8865-e3b3d08e44a8", "name": "p1rdt254", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef1d5226-a8f9-4454-a993-7cb000b03794"}}}}, {"uuid": "3c286a77-6cc8-436e-9fc7-c2d3036ddaba", "name": "", "x": 38.69595800578408, "y": -122.39252013725728, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8e28087b-b80e-4043-b0f0-0bc82c91f5e8", "name": "p1rdt258", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3c286a77-6cc8-436e-9fc7-c2d3036ddaba"}}}}, {"uuid": "804b2239-d5e8-48c0-9827-b37ecf5b0754", "name": "", "x": 38.697506302675386, "y": -122.39110055463347, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf660777-f77e-4d9b-afff-73a84274c270", "name": "p1rdt262", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "804b2239-d5e8-48c0-9827-b37ecf5b0754"}}}}, {"uuid": "c54df0ed-ada6-4bb9-a22a-77c5b1643b95", "name": "", "x": 38.6960521884224, "y": -122.39265347986003, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "209cebda-044a-42a3-b2f0-fe5b76b80643", "name": "p1rdt261", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c54df0ed-ada6-4bb9-a22a-77c5b1643b95"}}}}, {"uuid": "c2026069-787d-446d-98d6-de87e2aceec7", "name": "", "x": 38.696015106037905, "y": -122.39255812819005, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be0fa139-8da7-4cba-9e49-faf4a4814035", "name": "p1rdt258-p1rdt261x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c2026069-787d-446d-98d6-de87e2aceec7"}}}}, {"uuid": "4caf55e0-0b8c-407e-811a-83af58390919", "name": "", "x": 38.69712125423101, "y": -122.39909419849987, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bbe3ac37-aca0-47fd-ac5d-be390cad10ab", "name": "p1rdt261-p1rdt277x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4caf55e0-0b8c-407e-811a-83af58390919"}}}}, {"uuid": "4f2e309d-192c-4ca8-a1de-e92bdeb74d0c", "name": "", "x": 38.702132662964175, "y": -122.38784923319449, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a2b529c9-4695-42f3-a0e3-69bbb34ff285", "name": "p1rdt37-p1rdt80x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4f2e309d-192c-4ca8-a1de-e92bdeb74d0c"}}}}, {"uuid": "81d8b59a-049e-4f0c-be85-a34d084e4b44", "name": "", "x": 38.70165469665771, "y": -122.38758437608678, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9dcbfdc3-b597-4e9e-a86f-4d0ff396ba70", "name": "p1rdt37", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "81d8b59a-049e-4f0c-be85-a34d084e4b44"}}}}, {"uuid": "8f6e7c1a-1fd0-4353-ae0c-01e914a08470", "name": "", "x": 38.70226336170039, "y": -122.37889294477628, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a9c4411-f402-464c-ad25-d439b87ef768", "name": "p1rdt34", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8f6e7c1a-1fd0-4353-ae0c-01e914a08470"}}}}, {"uuid": "df30e6d5-4f96-4c9e-822f-7dc4d01fc1c6", "name": "", "x": 38.70240564817688, "y": -122.37853520540186, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "31b06630-2aae-4fe7-9e31-f911c91121cd", "name": "p1rdt77", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "df30e6d5-4f96-4c9e-822f-7dc4d01fc1c6"}}}}, {"uuid": "07e40688-ddb5-443c-82d8-7dfb1870c9b0", "name": "", "x": 38.70192539724856, "y": -122.37910641908904, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b45513a3-8e88-45e9-99d3-6d244c90c256", "name": "p1rdt38", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "07e40688-ddb5-443c-82d8-7dfb1870c9b0"}}}}, {"uuid": "26fcf062-38f3-4fc4-944a-64a938b61bab", "name": "", "x": 38.70129185446362, "y": -122.37973917584448, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "668d32be-c07a-4387-86a5-e9754af11e9c", "name": "p1rdt31-p1rdt38x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "26fcf062-38f3-4fc4-944a-64a938b61bab"}}}}, {"uuid": "ed47d79a-4bc3-482c-a4a9-cbd1e0f3ff3d", "name": "", "x": 38.701554940346995, "y": -122.37742353030349, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2b82a9a2-b1d1-44eb-a451-946643ef613d", "name": "p1rdt74-p1rdt85x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ed47d79a-4bc3-482c-a4a9-cbd1e0f3ff3d"}}}}, {"uuid": "eea93f53-2784-47ad-9645-52baa3baf1fb", "name": "", "x": 38.702210844779025, "y": -122.37749036925975, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b884fef-8b8f-4ed5-9033-b8177d1c7d70", "name": "p1rdt74", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eea93f53-2784-47ad-9645-52baa3baf1fb"}}}}, {"uuid": "147c7c3d-719e-47e9-9fbe-5d5d89ded094", "name": "", "x": 38.69878213406897, "y": -122.37500166002606, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf205ba7-ac66-4318-aeca-c75eb96cbd1e", "name": "p1rdt456", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "147c7c3d-719e-47e9-9fbe-5d5d89ded094"}}}}, {"uuid": "16e64a55-a47c-4563-9842-a45162327cac", "name": "", "x": 38.698844229551156, "y": -122.37481712432647, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cee642e7-12f0-4746-841e-d8cda6fff57e", "name": "p1rdt489", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "16e64a55-a47c-4563-9842-a45162327cac"}}}}, {"uuid": "2156d576-a0de-4c7f-8b6b-83a2796d5de4", "name": "", "x": 38.698450220223094, "y": -122.375819293565, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b092ee09-4c5e-46b5-8ec2-51f99254c220", "name": "p1rdt456-p1rdt465x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2156d576-a0de-4c7f-8b6b-83a2796d5de4"}}}}, {"uuid": "154ca468-f940-41a0-813f-c7a6390c0c78", "name": "", "x": 38.693782143657465, "y": -122.37465775612712, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "05082892-d69e-4c8f-ba19-c2a627e1c345", "name": "p1rdt46", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "154ca468-f940-41a0-813f-c7a6390c0c78"}}}}, {"uuid": "c6b93af1-6cb1-4ff7-847d-a8f8e24da09c", "name": "", "x": 38.69314320252447, "y": -122.37482430214054, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "50f3b5f3-3fb5-4fb9-b2e6-b37200af0901", "name": "p1rdt70", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c6b93af1-6cb1-4ff7-847d-a8f8e24da09c"}}}}, {"uuid": "c1697cd7-1b88-45cc-b5f6-415d8eb7a1bc", "name": "", "x": 38.69495141442872, "y": -122.3748625110079, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b61caefd-d5aa-4019-9ac0-aaf8cedc71d0", "name": "p1rdt458", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c1697cd7-1b88-45cc-b5f6-415d8eb7a1bc"}}}}, {"uuid": "886222cb-cab4-4cd2-836a-660c88e16dfa", "name": "", "x": 38.69185315698694, "y": -122.37350964662168, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2faff95d-f394-427a-9d62-75224f830c9e", "name": "p1rdt72", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "886222cb-cab4-4cd2-836a-660c88e16dfa"}}}}, {"uuid": "0ee4f148-fd6a-46ed-ad40-dd2c07a2bdea", "name": "", "x": 38.69169101529133, "y": -122.37352255937813, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a6fb1323-f697-4423-a70d-838056200402", "name": "p1rdt52", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0ee4f148-fd6a-46ed-ad40-dd2c07a2bdea"}}}}, {"uuid": "ec8d68dd-493a-4fc5-92b6-8771c3237b37", "name": "", "x": 38.693098193510316, "y": -122.37377475782415, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "137c345c-77cc-4324-bc0e-e0ba896a5f43", "name": "p1rdt49", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ec8d68dd-493a-4fc5-92b6-8771c3237b37"}}}}, {"uuid": "0990a9d9-e9d3-40e6-8e79-7a8bd3f851c3", "name": "", "x": 38.694135169317704, "y": -122.37389220491741, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1d8f5898-7d36-4e40-9980-76d11ef18adb", "name": "p1rdt56", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0990a9d9-e9d3-40e6-8e79-7a8bd3f851c3"}}}}, {"uuid": "560d2c90-f0c1-4f09-b2ab-5bdb242b8f86", "name": "", "x": 38.69445247244586, "y": -122.37424590782481, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6fa14b51-a977-4e40-8f9c-28249e576fcf", "name": "p1rdt472", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "560d2c90-f0c1-4f09-b2ab-5bdb242b8f86"}}}}, {"uuid": "5dc257f9-663e-496e-82ab-f02badf92781", "name": "", "x": 38.695584690016524, "y": -122.37575707999054, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "04fc215c-7f3e-45e1-a49c-727b0fcdae93", "name": "p1rdt458-p1rdt468x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5dc257f9-663e-496e-82ab-f02badf92781"}}}}, {"uuid": "c0ce7def-bf8a-4994-9211-1090a6708213", "name": "", "x": 38.69312267817216, "y": -122.37604335226409, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0c5d8237-0351-4eb2-83e6-13975b37bfa7", "name": "p1rdt50", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c0ce7def-bf8a-4994-9211-1090a6708213"}}}}, {"uuid": "a6e05e13-c59b-487a-a856-c53af892ec53", "name": "", "x": 38.69253761865749, "y": -122.37617492032506, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e7305e2b-0a48-4630-8b8e-c3819f1c9cd1", "name": "p1rdt53", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a6e05e13-c59b-487a-a856-c53af892ec53"}}}}, {"uuid": "d0d9e0b2-5201-4618-9538-651dea7a923c", "name": "", "x": 38.69357324297057, "y": -122.37603943809668, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4ea7e0bb-bdc5-429a-8889-2f12c94db72e", "name": "p1rdt59", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d0d9e0b2-5201-4618-9538-651dea7a923c"}}}}, {"uuid": "e2fdec26-5a5b-48a2-a148-888c835ac073", "name": "", "x": 38.69405568995833, "y": -122.37588221381021, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "577124ac-ea2b-4a60-be47-14b0f5db305e", "name": "p1rdt40", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e2fdec26-5a5b-48a2-a148-888c835ac073"}}}}, {"uuid": "49b5489f-b73f-492f-be37-43f9823f28f6", "name": "", "x": 38.69445481567878, "y": -122.37574430437743, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "12fef7fc-57f0-4494-becd-4724b84dbbcb", "name": "p1rdt457", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "49b5489f-b73f-492f-be37-43f9823f28f6"}}}}, {"uuid": "d2981dd6-bb67-4a21-b888-fa072ef2814d", "name": "", "x": 38.69524468972365, "y": -122.37577988845278, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d709af4b-1115-403b-a68d-76c63c93adf2", "name": "p1rdt474", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d2981dd6-bb67-4a21-b888-fa072ef2814d"}}}}, {"uuid": "036ca743-6e5f-4397-b298-e6da7abbbd82", "name": "", "x": 38.695656536068775, "y": -122.3757951768077, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5814195b-dd60-4a1e-9af6-b9b84fa4c0c7", "name": "p1rdt468-p1rdt474x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "036ca743-6e5f-4397-b298-e6da7abbbd82"}}}}, {"uuid": "7de12271-b8bc-4949-9775-db2f3d0fa8b9", "name": "", "x": 38.69416819650434, "y": -122.37332846825741, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f9397c58-45a1-4ec3-bd84-b4cd5b52dc80", "name": "p1rdt65", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7de12271-b8bc-4949-9775-db2f3d0fa8b9"}}}}, {"uuid": "f574c707-7785-4ef9-9cf6-4f890606558b", "name": "", "x": 38.69364252102314, "y": -122.37276961025155, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ab2b6727-4d87-4b00-bd49-ba7a6b1b9ce6", "name": "p1rdt63", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f574c707-7785-4ef9-9cf6-4f890606558b"}}}}, {"uuid": "ddcf1e4b-2864-4c58-9602-0c22fa480875", "name": "", "x": 38.69429429294349, "y": -122.37331586905341, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4ae86125-88c3-44fb-9fe9-1a5d820606f6", "name": "p1rdt467", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ddcf1e4b-2864-4c58-9602-0c22fa480875"}}}}, {"uuid": "df901f95-bfa5-4f1a-be8d-56be09dc1b3a", "name": "", "x": 38.69469140583874, "y": -122.37342739439052, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48179f57-b0b9-491b-b654-81583768923a", "name": "p1rdt469", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "df901f95-bfa5-4f1a-be8d-56be09dc1b3a"}}}}, {"uuid": "956e346e-1e34-4cec-b6f1-259a87f18ad5", "name": "", "x": 38.69542702599285, "y": -122.37386149152691, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a634585d-0c70-428e-a3b2-1ec4717d7878", "name": "p1rdt464", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "956e346e-1e34-4cec-b6f1-259a87f18ad5"}}}}, {"uuid": "09d2e6ee-2f60-4e01-83a5-962fd176bb64", "name": "", "x": 38.69557377117983, "y": -122.37396893690091, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2e5c3d02-1cd2-45e4-90d3-10b135c65f13", "name": "p1rdt480", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "09d2e6ee-2f60-4e01-83a5-962fd176bb64"}}}}, {"uuid": "5a7937d8-a3eb-45f2-b178-6c3eead7e7cc", "name": "", "x": 38.69642974090264, "y": -122.37431272204606, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "76880999-6f79-4fc6-9367-1c419eee26d5", "name": "p1rdt473", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5a7937d8-a3eb-45f2-b178-6c3eead7e7cc"}}}}, {"uuid": "fea57a38-f4cb-464a-aeee-8c88416598f1", "name": "", "x": 38.69676892757635, "y": -122.37432921866969, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d1bb6f93-7aed-47d7-99db-7c17352a42b8", "name": "p1rdt453", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fea57a38-f4cb-464a-aeee-8c88416598f1"}}}}, {"uuid": "7de38676-e68c-41bd-b881-6545360d00a9", "name": "", "x": 38.697042200822686, "y": -122.37424988896967, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d51e6f65-c45c-4f10-a17f-6ef684a0a06c", "name": "p1rdt452", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7de38676-e68c-41bd-b881-6545360d00a9"}}}}, {"uuid": "d1220ca0-5321-4d82-a08a-3738153e2860", "name": "", "x": 38.69788387901549, "y": -122.3749210284041, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b20fa59a-8573-461a-9c4a-0d47e40d2601", "name": "p1rdt466", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1220ca0-5321-4d82-a08a-3738153e2860"}}}}, {"uuid": "c75db6cf-545e-48dc-8ac1-330cef2f7643", "name": "", "x": 38.69827011722288, "y": -122.37584385822461, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "64ba6716-89f9-49a4-9793-ba80ae41bcd0", "name": "p1rdt466-p1rdt478x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c75db6cf-545e-48dc-8ac1-330cef2f7643"}}}}, {"uuid": "715de1e8-65e3-4ad3-9996-d73649cb2471", "name": "", "x": 38.701722794560474, "y": -122.37384904824599, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "12d5c579-0570-44db-a751-8eeb92355af9", "name": "p1rdt459", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "715de1e8-65e3-4ad3-9996-d73649cb2471"}}}}, {"uuid": "a4a0e6c6-1a05-444c-8d95-22a456abb8b6", "name": "", "x": 38.701153728978355, "y": -122.37360100904912, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eed7e6a8-2b4a-4a54-b69a-e3e1a0614213", "name": "p1rdt471", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a4a0e6c6-1a05-444c-8d95-22a456abb8b6"}}}}, {"uuid": "9c8b7067-51d1-4537-b1ae-3e54b168100a", "name": "", "x": 38.702243046289325, "y": -122.3733960017453, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fcfdc5bf-1c87-42e2-8b35-1f7125d3b5ed", "name": "p1rdt462", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9c8b7067-51d1-4537-b1ae-3e54b168100a"}}}}, {"uuid": "f13eb1dc-c712-49aa-af69-41037bc6049a", "name": "", "x": 38.702902444369066, "y": -122.37348707489292, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dfb0d992-ab18-4f73-933e-a01ce73ef3b2", "name": "p1rdt487", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f13eb1dc-c712-49aa-af69-41037bc6049a"}}}}, {"uuid": "76e35c9a-9560-4eeb-8df3-09560a9c278e", "name": "", "x": 38.72548231736972, "y": -122.31263452007998, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4774ed1a-85ec-4ca0-8e9a-3b232588fb0c", "name": "p1rdt16790", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "76e35c9a-9560-4eeb-8df3-09560a9c278e"}}}}, {"uuid": "0265a43f-a1e0-4db0-b8c6-5963dd5ac674", "name": "", "x": 38.7248434734621, "y": -122.31174862017714, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d4bc644c-9875-4846-8b0f-dfa0568de623", "name": "p1rdt16787", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0265a43f-a1e0-4db0-b8c6-5963dd5ac674"}}}}, {"uuid": "20c89e0d-0eeb-4562-be97-b9842e309720", "name": "", "x": 38.741935598212194, "y": -122.27647050486847, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d29266e8-ce67-45bf-93d9-710d4684ce0b", "name": "p1rdt16790-p1rdt16911x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "20c89e0d-0eeb-4562-be97-b9842e309720"}}}}, {"uuid": "7e5d3205-621f-494a-ab6d-fad769918f9e", "name": "", "x": 38.743604391211804, "y": -122.2733738127215, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "725fbd98-74ba-4143-8947-da9fdc209889", "name": "p1rdt16911", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7e5d3205-621f-494a-ab6d-fad769918f9e"}}}}, {"uuid": "42ca79ed-f62f-4ac0-9102-c9659c386bdb", "name": "", "x": 38.70287643040543, "y": -122.37344445127026, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d53ff9fd-2b16-4026-88fa-2c112d4949c5", "name": "p1rdt16790-p1rdt487xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "42ca79ed-f62f-4ac0-9102-c9659c386bdb"}}}}, {"uuid": "c0e3a7e7-c16f-4b7d-a18a-6aab1ae6d4da", "name": "", "x": 38.703325006090246, "y": -122.37234754500905, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a1b5b099-df99-4729-a26d-f0882e93136f", "name": "p1rdt16790-p1rdt487x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c0e3a7e7-c16f-4b7d-a18a-6aab1ae6d4da"}}}}, {"uuid": "21750166-4903-4b4c-ba19-0e6b7f9489e0", "name": "", "x": 38.70318635641241, "y": -122.37390883465856, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b57b8e2b-62c2-49a0-801d-02cab8092ebd", "name": "p1rdt484", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "21750166-4903-4b4c-ba19-0e6b7f9489e0"}}}}, {"uuid": "2b9e9c66-5072-4da7-8003-57c1fa927b48", "name": "", "x": 38.70352176107739, "y": -122.37490290192596, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bd2f4b00-6e8b-4faa-a760-7c28f8d36a36", "name": "p1rdt486", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2b9e9c66-5072-4da7-8003-57c1fa927b48"}}}}, {"uuid": "d8957db5-cbe5-4d00-85fe-945d701e8053", "name": "", "x": 38.7035351825914, "y": -122.37510184014613, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "10c2463d-8563-4737-aa7d-e1195c0af9f6", "name": "p1rdt482", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d8957db5-cbe5-4d00-85fe-945d701e8053"}}}}, {"uuid": "d3f45a56-1323-4e5a-bb45-4854c58e77f0", "name": "", "x": 38.70367069880678, "y": -122.37631203298449, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e4064b6c-40b4-418b-95ab-4f9bb0363b14", "name": "p1rdt482-p1rdt485x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d3f45a56-1323-4e5a-bb45-4854c58e77f0"}}}}, {"uuid": "95d9dc99-1cb5-461e-a945-a57274c2eebd", "name": "", "x": 38.70062992258327, "y": -122.37444862489892, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d1eb09d-dff4-4fa3-b96f-ef59b63d6128", "name": "p1rdt477", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "95d9dc99-1cb5-461e-a945-a57274c2eebd"}}}}, {"uuid": "0a21d1b9-6ab1-49d5-a780-884c93792a4d", "name": "", "x": 38.70017599315202, "y": -122.374449032179, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5421facb-0713-404c-97e9-56669fc762b3", "name": "p1rdt476", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a21d1b9-6ab1-49d5-a780-884c93792a4d"}}}}, {"uuid": "5d69f592-01fb-4253-8b5f-8e5d349e1d8a", "name": "", "x": 38.7012326324604, "y": -122.37424787273476, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "85acd1fb-6da3-432a-9508-855ca991641b", "name": "p1rdt479", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5d69f592-01fb-4253-8b5f-8e5d349e1d8a"}}}}, {"uuid": "5cef3667-c445-4b39-bb1f-8c1ab800b88d", "name": "", "x": 38.70153006625403, "y": -122.37425678080724, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "82459f47-0c6f-4173-8c35-5a9fe5db9713", "name": "p1rdt454", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5cef3667-c445-4b39-bb1f-8c1ab800b88d"}}}}, {"uuid": "c3d04bfb-0722-4c14-b3e2-2a08a319c69e", "name": "", "x": 38.701876062215334, "y": -122.37492077650421, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "183de04a-a665-4112-a912-1df68b61d164", "name": "p1rdt455", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c3d04bfb-0722-4c14-b3e2-2a08a319c69e"}}}}, {"uuid": "98278fc0-28a5-42e6-bb31-86f9b808baa4", "name": "", "x": 38.70221801359906, "y": -122.37545476381091, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "59b616e5-76b8-406c-843f-5c71398af81b", "name": "p1rdt460", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "98278fc0-28a5-42e6-bb31-86f9b808baa4"}}}}, {"uuid": "dea738bd-0034-4241-af54-c69d1a1de21a", "name": "", "x": 38.702478034778096, "y": -122.37458202766794, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "86178159-ccd7-45a3-b711-ac237321d52a", "name": "p1rdt470", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dea738bd-0034-4241-af54-c69d1a1de21a"}}}}, {"uuid": "17dc86f4-06a4-4f36-a0c0-053ed5d6918b", "name": "", "x": 38.702879570888186, "y": -122.37552155877664, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "69b5d686-dae0-44c5-a261-f1a73bcb168e", "name": "p1rdt483", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "17dc86f4-06a4-4f36-a0c0-053ed5d6918b"}}}}, {"uuid": "f3209dfb-0d4c-454f-b128-6d905623f51c", "name": "", "x": 38.703660453271056, "y": -122.37621331185325, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d899b807-b194-4f65-bad5-a39e8bc61906", "name": "p1rdt483-p1rdt485x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f3209dfb-0d4c-454f-b128-6d905623f51c"}}}}, {"uuid": "3cdd14db-f66c-40e6-a154-04d71f132931", "name": "", "x": 38.696234466020165, "y": -122.4029175301028, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "232adbbb-2715-44be-8db5-ee062ebf4e46", "name": "p1rdt279-p1rdt89x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3cdd14db-f66c-40e6-a154-04d71f132931"}}}}, {"uuid": "d36ac9a4-d6a8-48ba-a00f-294724d9c50b", "name": "", "x": 38.6936090734191, "y": -122.40307695118932, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "416118a8-65b7-4d9e-90a2-454f065bfddb", "name": "p1rdt279-p1rdt89xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d36ac9a4-d6a8-48ba-a00f-294724d9c50b"}}}}, {"uuid": "5a37f945-3b6c-4993-8b09-bd86f15e9ca8", "name": "", "x": 38.691921020060555, "y": -122.4037273791967, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ac4ad276-90cb-48c0-bfd0-1f2aa0233ce2", "name": "p1rdt89", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5a37f945-3b6c-4993-8b09-bd86f15e9ca8"}}}}, {"uuid": "1d7465a0-15cf-41d5-961d-c03eaf8bcc3c", "name": "", "x": 38.71273376728585, "y": -122.26236860525948, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d50d3e76-470b-47c2-ada2-da944962b322", "name": "p1rdt16427", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d7465a0-15cf-41d5-961d-c03eaf8bcc3c"}}}}, {"uuid": "832689e9-558f-4425-9e83-1b5db67ee44f", "name": "", "x": 38.713290303421466, "y": -122.26149228450026, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "18e3da78-83fc-4b8e-9d45-41adb9b753ad", "name": "p1rdt16424", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "832689e9-558f-4425-9e83-1b5db67ee44f"}}}}, {"uuid": "7fec0620-591f-4608-b812-80cf87d91f9d", "name": "", "x": 38.69570787792313, "y": -122.29851285731566, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8e35a4f7-19c1-4f59-9adc-b267f6088264", "name": "p1rdt16847", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7fec0620-591f-4608-b812-80cf87d91f9d"}}}}, {"uuid": "6704537b-9d53-40b6-b9e8-e67e3d651524", "name": "", "x": 38.71191996461427, "y": -122.26381070914681, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a6382a2-8c21-4cb4-a39b-3f1ac62cc705", "name": "p1rdt16427-p1rdt16847x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6704537b-9d53-40b6-b9e8-e67e3d651524"}}}}, {"uuid": "cc64522b-669a-4319-93fb-4f32f3956d1b", "name": "", "x": 38.68960809733261, "y": -122.30930023811142, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "61d5dee2-30f8-434d-8c03-76bccff72549", "name": "p1rdt16404", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc64522b-669a-4319-93fb-4f32f3956d1b"}}}}, {"uuid": "27628ce8-d3dd-4b33-8235-963ca36f778a", "name": "", "x": 38.69038163570117, "y": -122.31517993828531, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c5b51836-1807-4fab-b877-94a62021569f", "name": "p1rdt16394", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "27628ce8-d3dd-4b33-8235-963ca36f778a"}}}}, {"uuid": "420ccfac-7dbd-4510-83b6-2bea0e849955", "name": "", "x": 38.684262624044464, "y": -122.31767924836156, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b5a9e0f5-d824-4a76-a4f0-88aab072280e", "name": "p1rdt16603", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "420ccfac-7dbd-4510-83b6-2bea0e849955"}}}}, {"uuid": "88bd7eea-2f21-4a0d-879d-c3a70ed66def", "name": "", "x": 38.68314419705685, "y": -122.31905803173453, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "98a946e8-3c8a-49ec-be8a-5610c7fc596c", "name": "p1rdt16604", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "88bd7eea-2f21-4a0d-879d-c3a70ed66def"}}}}, {"uuid": "4fd2ad5d-d4e0-480c-a014-3cc3aa2fa98d", "name": "", "x": 38.68864067156756, "y": -122.34840259338564, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ef71bd7-4c82-4296-a6ac-64516ffe96c5", "name": "p1rdt16604-p1rdt257x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4fd2ad5d-d4e0-480c-a014-3cc3aa2fa98d"}}}}, {"uuid": "f00cd8ba-b7f8-491a-b665-015a9277eadf", "name": "", "x": 38.68800685251441, "y": -122.34473682420163, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "282d8a89-8b14-476b-9e55-b310d8b9396d", "name": "p1rdt16604-p1rdt257x_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f00cd8ba-b7f8-491a-b665-015a9277eadf"}}}}, {"uuid": "1e961363-685e-4320-a9c9-c6a11ef0dc32", "name": "", "x": 38.68510682934324, "y": -122.35589682226349, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dcb27aab-e828-41a6-ad98-d197897a1a69", "name": "p1rdt209", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1e961363-685e-4320-a9c9-c6a11ef0dc32"}}}}, {"uuid": "a0cc6f33-f3de-4070-97bb-48c0aa09dfbf", "name": "", "x": 38.688681896745614, "y": -122.34841487443683, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3fb307f7-3690-4931-999a-4daab4d8c9e5", "name": "p1rdt257", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a0cc6f33-f3de-4070-97bb-48c0aa09dfbf"}}}}, {"uuid": "c26732ea-f986-41bc-95b2-b21b77a33f93", "name": "", "x": 38.68463781682152, "y": -122.35798033063733, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5d782d5e-3960-415c-9e33-6742777a5a0a", "name": "p1rdt210", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c26732ea-f986-41bc-95b2-b21b77a33f93"}}}}, {"uuid": "49ded750-7593-4589-9e1f-5c12c16bb481", "name": "", "x": 38.683540995258845, "y": -122.35679446809597, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b9401940-26a4-40f3-9b9a-5231a5c4e171", "name": "p1rdt211", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "49ded750-7593-4589-9e1f-5c12c16bb481"}}}}, {"uuid": "365a5752-e72f-4dc2-b314-1e000a8741e4", "name": "", "x": 38.68281023348963, "y": -122.35409734055312, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b89bfea1-97cd-41f7-af59-9602a3fc6c06", "name": "p1rdt278", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "365a5752-e72f-4dc2-b314-1e000a8741e4"}}}}, {"uuid": "8d37cf05-96a3-4d8e-bc5c-a40817f491c0", "name": "", "x": 38.68941008309863, "y": -122.37010832848992, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d1be5e34-ad5e-4c78-8067-8e0194c661a4", "name": "p1rdt210-p1rdt44x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8d37cf05-96a3-4d8e-bc5c-a40817f491c0"}}}}, {"uuid": "d48bab44-c136-4b4b-b5ef-2edb555ca1aa", "name": "", "x": 38.689335231948924, "y": -122.37012765218032, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f0b5743e-c3fd-49c7-879e-9be7d00c480f", "name": "p1rdt259-p1rdt44x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d48bab44-c136-4b4b-b5ef-2edb555ca1aa"}}}}, {"uuid": "d3241610-de63-4356-9931-09d85e05faa4", "name": "", "x": 38.68475989424937, "y": -122.36996130497471, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33a0a070-9cce-4a82-bd22-24a65f02ef97", "name": "p1rdt259", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d3241610-de63-4356-9931-09d85e05faa4"}}}}, {"uuid": "6861d9ef-ae9d-4bcd-b45d-e3cea1fee6da", "name": "", "x": 38.69119253254578, "y": -122.3723691075126, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7728581d-66fc-4e7e-b2b0-85fa02c90523", "name": "p1rdt43", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6861d9ef-ae9d-4bcd-b45d-e3cea1fee6da"}}}}, {"uuid": "99953f4d-982e-4c24-b529-2f7f64d2139a", "name": "", "x": 38.69217068541305, "y": -122.3732804512017, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1ea0531d-530c-4088-86a1-3de96a8938ea", "name": "p1rdt47", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "99953f4d-982e-4c24-b529-2f7f64d2139a"}}}}, {"uuid": "b9bda6ac-99c6-477c-960d-36334462a180", "name": "", "x": 38.692501666976284, "y": -122.37176768850954, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1667a8c6-aeb4-4f22-97b8-62ffefcc12a4", "name": "p1rdt48", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b9bda6ac-99c6-477c-960d-36334462a180"}}}}, {"uuid": "6fa6d556-40b3-48e9-9dd4-53c85726e76f", "name": "", "x": 38.69243929619441, "y": -122.37127733774665, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4f5cef5c-bcaf-4cd9-afbb-a18bd14dfcd4", "name": "p1rdt51", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6fa6d556-40b3-48e9-9dd4-53c85726e76f"}}}}, {"uuid": "a02913b0-c109-4683-9794-a5abb4af1cd6", "name": "", "x": 38.69084016635201, "y": -122.37219971004839, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d99e903-3536-4a73-b0d5-ca11f5af6e32", "name": "p1rdt60", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a02913b0-c109-4683-9794-a5abb4af1cd6"}}}}, {"uuid": "b593050b-e132-4544-810f-e168f484e82a", "name": "", "x": 38.69044403976456, "y": -122.37227216228393, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a4ccf80-2611-4089-9353-439809aa7854", "name": "p1rdt58", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b593050b-e132-4544-810f-e168f484e82a"}}}}, {"uuid": "faf45571-2233-4e14-8dbd-a4cb9bb93984", "name": "", "x": 38.690014841841176, "y": -122.3723741213489, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7238345a-1fc7-4f3f-bc8b-88cf7582c75c", "name": "p1rdt58-p1rdt69x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "faf45571-2233-4e14-8dbd-a4cb9bb93984"}}}}, {"uuid": "cb7173bb-4199-4353-9284-a0bc9e239ac0", "name": "", "x": 38.691521445820555, "y": -122.37639464686723, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bcea1fd6-3c51-48af-8528-d3d7bc8e4f01", "name": "p1rdt71", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb7173bb-4199-4353-9284-a0bc9e239ac0"}}}}, {"uuid": "6063cb06-32cd-4338-85e5-260df69cd2de", "name": "", "x": 38.69124250818054, "y": -122.37559619861726, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "744725a8-af2a-47cf-948f-9d453a932e32", "name": "p1rdt61", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6063cb06-32cd-4338-85e5-260df69cd2de"}}}}, {"uuid": "ddcdbfed-3171-4fa1-b47a-20f5a01c95ab", "name": "", "x": 38.69156944308755, "y": -122.37634466226288, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eab6b8c5-ee7a-4779-b5eb-5205dbe5253c", "name": "p1rdt150-p1rdt71x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ddcdbfed-3171-4fa1-b47a-20f5a01c95ab"}}}}, {"uuid": "91db4e45-8d24-4b88-9548-edc1fcce5953", "name": "", "x": 38.69156345018649, "y": -122.37716473257039, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf5b238a-832f-4f45-8a36-2248549e1723", "name": "p1rdt150-p1rdt71xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "91db4e45-8d24-4b88-9548-edc1fcce5953"}}}}, {"uuid": "ef35acf6-032c-4963-a01f-2230eacca63a", "name": "", "x": 38.686995650033, "y": -122.45197514226767, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0f2a0358-b10d-4b62-8f8d-9a5054fae87d", "name": "p1rdt376", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef35acf6-032c-4963-a01f-2230eacca63a"}}}}, {"uuid": "8f3f93e7-1578-47b2-86b9-794346f706ac", "name": "", "x": 38.68750853010239, "y": -122.45098420292979, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d425a00d-c0e9-465d-9d9b-af4d64708fba", "name": "p1rdt374", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8f3f93e7-1578-47b2-86b9-794346f706ac"}}}}, {"uuid": "19d36e6c-2460-47b8-9e33-b4dcbcb80539", "name": "", "x": 38.68515597552901, "y": -122.45198911454673, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0de112ae-d04a-4673-98af-0699e4890429", "name": "p1rdt335-p1rdt376x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "19d36e6c-2460-47b8-9e33-b4dcbcb80539"}}}}, {"uuid": "af233a4c-7d45-41d9-a62c-72de519562f2", "name": "", "x": 38.67357675550989, "y": -122.4699912914106, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "101c6236-a474-45c8-b065-f5fa045b1107", "name": "p1rdt415", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "af233a4c-7d45-41d9-a62c-72de519562f2"}}}}, {"uuid": "9f19600a-edcd-46ba-ae35-6e1056793679", "name": "", "x": 38.67350163747049, "y": -122.4708045160677, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "71fa675e-bc20-46f7-b6f1-c88962f9f3cb", "name": "p1rdt417", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9f19600a-edcd-46ba-ae35-6e1056793679"}}}}, {"uuid": "bea72cbb-7842-4b45-817f-7fb1e09441f5", "name": "", "x": 38.67293062003175, "y": -122.46738711812904, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "19116f3c-29ae-4819-ba72-dd0f8afa5078", "name": "p1rdt415-p1rdt419x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bea72cbb-7842-4b45-817f-7fb1e09441f5"}}}}, {"uuid": "8d8841bf-aa27-4b28-ac54-de67f23e7732", "name": "", "x": 38.665494529835904, "y": -122.46043005782059, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9100fbd6-863e-48b2-94ed-aca1ef0947bd", "name": "p1rdt5098", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8d8841bf-aa27-4b28-ac54-de67f23e7732"}}}}, {"uuid": "5813a119-def8-4d45-b4bb-5d832ab51878", "name": "", "x": 38.66895816218114, "y": -122.45865330515163, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5258d4de-be4c-478d-b752-7f4efb0af0a5", "name": "p1rdt180", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5813a119-def8-4d45-b4bb-5d832ab51878"}}}}, {"uuid": "8c5463e5-55d2-48d9-b10f-67b2ccace9cd", "name": "", "x": 38.66514031344027, "y": -122.44753960527862, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9f273a36-c30d-4962-81f4-26f8d20e1cf4", "name": "p1rdt6584", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8c5463e5-55d2-48d9-b10f-67b2ccace9cd"}}}}, {"uuid": "71bd4c9c-02a9-484c-aca4-ac5ffddf68dd", "name": "", "x": 38.66464311110499, "y": -122.44791919098567, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e257530-1fe2-410b-83a1-57789e6ddeda", "name": "p1rdt6578", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "71bd4c9c-02a9-484c-aca4-ac5ffddf68dd"}}}}, {"uuid": "6a0a739a-8c43-452d-ac2c-72a7a7e2d4d6", "name": "", "x": 38.66574098458345, "y": -122.44687980665202, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1648fe3-a7f9-47aa-b168-d2b56cf220e7", "name": "p1rdt6588", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a0a739a-8c43-452d-ac2c-72a7a7e2d4d6"}}}}, {"uuid": "c3aa5e75-c547-4302-a29e-0a307e7e49c0", "name": "", "x": 38.66451724050103, "y": -122.44667705028046, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1d0a85a-62dc-46d2-bae1-d43d07743a34", "name": "p1rdt6591", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c3aa5e75-c547-4302-a29e-0a307e7e49c0"}}}}, {"uuid": "9e340273-38a6-48fe-869c-873f661a3243", "name": "", "x": 38.664682198133455, "y": -122.446168239027, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5291ea2b-6990-407b-b8d4-d6868bf37310", "name": "p1rdt6590", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9e340273-38a6-48fe-869c-873f661a3243"}}}}, {"uuid": "48f38dca-aa76-4927-9b84-65ffec914a19", "name": "", "x": 38.666084365577824, "y": -122.44838916371525, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d77add8e-ba22-4b44-9c0b-0bddc251a573", "name": "p1rdt6587", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "48f38dca-aa76-4927-9b84-65ffec914a19"}}}}, {"uuid": "70b56e2a-5e1c-4c12-a230-51d8f4fdc039", "name": "", "x": 38.6658846543716, "y": -122.44807809992015, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b918e583-d163-4136-aaf8-62085c7b0c17", "name": "p1rdt6584-p1rdt6587x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "70b56e2a-5e1c-4c12-a230-51d8f4fdc039"}}}}, {"uuid": "42b72520-be1d-4c12-a534-0a09bcbf8c0b", "name": "", "x": 38.66666084985903, "y": -122.45155897573034, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "68298e92-fca3-44e9-9271-f79be47c9c63", "name": "p1rdt6580", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "42b72520-be1d-4c12-a534-0a09bcbf8c0b"}}}}, {"uuid": "9700ef27-7399-42c3-a41c-ba76f3a5ba0d", "name": "", "x": 38.66481336487895, "y": -122.46776680294279, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cb3d775d-8d92-498b-989c-387278ec8e9e", "name": "p1rdt5098-p1rdt8169x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9700ef27-7399-42c3-a41c-ba76f3a5ba0d"}}}}, {"uuid": "f5375e9b-fd09-4d67-abb9-558b3cc8346c", "name": "", "x": 38.66954985597873, "y": -122.47289306798201, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16b7f1e9-3405-4c5f-96c7-d5c08d791907", "name": "p1rdt418", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5375e9b-fd09-4d67-abb9-558b3cc8346c"}}}}, {"uuid": "0dd337d1-0ca4-48d8-8854-be2ef5efcfc5", "name": "", "x": 38.669198863842276, "y": -122.47439167095719, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3034e62-dd19-4ecb-bb39-6d0566e3a2ef", "name": "p1rdt414", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0dd337d1-0ca4-48d8-8854-be2ef5efcfc5"}}}}, {"uuid": "451ee1d6-69bb-4c5a-add8-b26af72700e1", "name": "", "x": 38.669612414212985, "y": -122.47279835298632, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ba78164d-d6ae-413b-8d24-067d8d38b28f", "name": "p1rdt416-p1rdt418x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "451ee1d6-69bb-4c5a-add8-b26af72700e1"}}}}, {"uuid": "13226904-e2e9-4814-b434-26821b104bc7", "name": "", "x": 38.671409309606254, "y": -122.47045206876079, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d16d5f5e-a376-4e39-a845-d2cde8800da3", "name": "p1rdt416", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "13226904-e2e9-4814-b434-26821b104bc7"}}}}, {"uuid": "48de8757-efa8-483a-8c9c-5c4f6109a371", "name": "", "x": 38.666461847991535, "y": -122.47096331177207, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1e3d41a7-06a4-460b-aa6c-3a60c8d2de10", "name": "p1rdt8201", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "48de8757-efa8-483a-8c9c-5c4f6109a371"}}}}, {"uuid": "ab0cc721-fe40-47c1-af8d-c996d017fdd8", "name": "", "x": 38.66526928202583, "y": -122.47027798516622, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "63928702-c44a-4e83-9cca-7ce77bdbd2b3", "name": "p1rdt8180-p1rdt8201x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ab0cc721-fe40-47c1-af8d-c996d017fdd8"}}}}, {"uuid": "22822696-ace4-4b6e-9db9-cf01859dd5b7", "name": "", "x": 38.658100245225164, "y": -122.48194171749711, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "246ad62e-5a10-4031-94e7-1732f58f1da9", "name": "p1rdt9055", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "22822696-ace4-4b6e-9db9-cf01859dd5b7"}}}}, {"uuid": "42866221-5545-4352-b430-fcf9cba1b4d0", "name": "", "x": 38.658393900938755, "y": -122.48112128391094, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cd9ea283-dbd2-4f38-b298-86a191c99bd2", "name": "p1rdt6265-p1rdt9055x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "42866221-5545-4352-b430-fcf9cba1b4d0"}}}}, {"uuid": "e03f9558-f8a9-4c77-88dd-fd9becc4fa78", "name": "", "x": 38.66056852061021, "y": -122.48035453306898, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2d316c13-77c1-4412-baf9-801f7e5ae407", "name": "p1rdt6265", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e03f9558-f8a9-4c77-88dd-fd9becc4fa78"}}}}, {"uuid": "60ff6017-72bc-4e90-890f-a061fd92703b", "name": "", "x": 38.65517194896592, "y": -122.48092661777345, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "30adfcd5-405b-47ea-be54-55c5a47c835f", "name": "p1rdt5560-p1rdt9055x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "60ff6017-72bc-4e90-890f-a061fd92703b"}}}}, {"uuid": "486eb953-e908-4a2e-a027-ef91dd99a6d8", "name": "", "x": 38.65725844991055, "y": -122.4811294760667, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "708f65d6-b869-4d26-930d-0e669caf4ffb", "name": "p1rdt5560-p1rdt9055xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "486eb953-e908-4a2e-a027-ef91dd99a6d8"}}}}, {"uuid": "28380f22-c0fa-475d-b399-b1cf74e2d018", "name": "", "x": 38.65230276217263, "y": -122.47461858577147, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d2ea25e-3d48-4b1d-9e52-768752de2e09", "name": "p1rdt7737", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "28380f22-c0fa-475d-b399-b1cf74e2d018"}}}}, {"uuid": "8f2f7c97-e09b-479b-837d-464111202a96", "name": "", "x": 38.65261575836355, "y": -122.4740602281008, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d142315b-a247-4a4d-a178-73e3c150a188", "name": "p1rdt7753", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8f2f7c97-e09b-479b-837d-464111202a96"}}}}, {"uuid": "5e5b7087-e9b0-48be-b147-19fd7f3264c1", "name": "", "x": 38.65184325416811, "y": -122.47515027973938, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4413ca7f-fdd1-484e-a0ba-3ff2447ebfef", "name": "p1rdt7791", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5e5b7087-e9b0-48be-b147-19fd7f3264c1"}}}}, {"uuid": "5d9e1eac-53fe-4947-b515-8daa7226ff69", "name": "", "x": 38.65207704845808, "y": -122.47515639717327, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0946738d-95de-4ad6-9d56-c043cb64c0e4", "name": "p1rdt7737-p1rdt7791x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5d9e1eac-53fe-4947-b515-8daa7226ff69"}}}}, {"uuid": "2826c794-b792-4ddc-8cc3-299a0c520ed3", "name": "", "x": 38.650951110512295, "y": -122.47644062493562, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "02351140-e632-49e2-83e4-7e5bc1c8856a", "name": "p1rdt7286", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2826c794-b792-4ddc-8cc3-299a0c520ed3"}}}}, {"uuid": "bd1fc43e-5a7b-4ff3-a94b-13041d21829c", "name": "", "x": 38.650648984972726, "y": -122.4768636646543, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8f8375b7-7bdd-409c-9fa1-5c13bd233364", "name": "p1rdt7289", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bd1fc43e-5a7b-4ff3-a94b-13041d21829c"}}}}, {"uuid": "1021a436-70ff-46d2-a2b1-36a6647e3118", "name": "", "x": 38.64944561704761, "y": -122.4757921819993, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4afa9bec-d8da-4449-ab96-9f875bae3c33", "name": "p1rdt7293", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1021a436-70ff-46d2-a2b1-36a6647e3118"}}}}, {"uuid": "69c7c6c7-1a98-4695-8108-a198c0b20ae5", "name": "", "x": 38.65290986333587, "y": -122.48317621935037, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0c83b6ee-20fc-4ca0-a778-44735283afd5", "name": "p1rdt5568", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "69c7c6c7-1a98-4695-8108-a198c0b20ae5"}}}}, {"uuid": "4426b99d-b785-4e5c-8972-5c972cdc1537", "name": "", "x": 38.653647469597004, "y": -122.48368389304464, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c8aa126c-9b2b-4ae0-a4fc-36d4201762a0", "name": "p1rdt5551-p1rdt5568xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4426b99d-b785-4e5c-8972-5c972cdc1537"}}}}, {"uuid": "ead5b8ed-3484-430c-a8ae-dc48d05070f0", "name": "", "x": 38.653032242675096, "y": -122.48324009208464, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "65eb08cf-6350-410a-88c2-3b318d3a262a", "name": "p1rdt5551-p1rdt5568xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ead5b8ed-3484-430c-a8ae-dc48d05070f0"}}}}, {"uuid": "3e1daa0b-ddcc-4ad5-9f93-673e981a9174", "name": "", "x": 38.652900682241246, "y": -122.48322892310364, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "64aba8d5-1dd3-4741-a8ba-26801e275ba8", "name": "p1rdt5551-p1rdt5568xxxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e1daa0b-ddcc-4ad5-9f93-673e981a9174"}}}}, {"uuid": "231d6b41-e4d1-42bc-9618-d294db1cb3a1", "name": "", "x": 38.65348179379366, "y": -122.4842621130032, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0c49b671-0b2b-43c9-bcb5-21c7b7e716ce", "name": "p1rdt5548-p1rdt5577xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "231d6b41-e4d1-42bc-9618-d294db1cb3a1"}}}}, {"uuid": "ea0b67e7-491e-44da-a05f-d51bc1dc6c07", "name": "", "x": 38.652151086540165, "y": -122.48369686652708, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fead5749-3ba7-4ead-a604-e8adbd18f8c2", "name": "p1rdt5548-p1rdt5577xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea0b67e7-491e-44da-a05f-d51bc1dc6c07"}}}}, {"uuid": "202ca4fc-f7c0-4c03-85d6-93e58cf5c199", "name": "", "x": 38.67222953111598, "y": -122.47625831645591, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c51ccb17-eed6-4ce0-b839-e7b26001fe3e", "name": "p1rdt304", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "202ca4fc-f7c0-4c03-85d6-93e58cf5c199"}}}}, {"uuid": "cf4d842f-4898-4504-99b0-7952f53b6158", "name": "", "x": 38.67878840609695, "y": -122.47525103045935, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "08e378d4-4ca6-4c9e-93fa-36ff87a3cf0f", "name": "p1rdt182", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cf4d842f-4898-4504-99b0-7952f53b6158"}}}}, {"uuid": "78af3e58-f400-406c-bd8e-efa3077f8637", "name": "", "x": 38.67077336251232, "y": -122.47582856074445, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7b936973-54dc-41e7-a413-8932c31f0793", "name": "p1rdt305", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "78af3e58-f400-406c-bd8e-efa3077f8637"}}}}, {"uuid": "8019fa58-ddff-4d58-9d54-6ba68f47b6af", "name": "", "x": 38.670527094141356, "y": -122.4798175179331, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9672c49b-8316-4907-b204-7505483210b0", "name": "p1rdt303", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8019fa58-ddff-4d58-9d54-6ba68f47b6af"}}}}, {"uuid": "d4d6f94f-f802-4308-9407-6b6546edf927", "name": "", "x": 38.66807769283756, "y": -122.48429523464395, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3ad84ef4-4dcc-42f7-99ed-b8d21cebc465", "name": "p1rdt177", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d4d6f94f-f802-4308-9407-6b6546edf927"}}}}, {"uuid": "4d1b6692-00b6-48e4-badf-57286e495511", "name": "", "x": 38.67120072595356, "y": -122.49044397744001, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "57a78c71-e5a8-4dfd-8359-e368b7b198fa", "name": "p1rdt306", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d1b6692-00b6-48e4-badf-57286e495511"}}}}, {"uuid": "ceeea650-e1b4-4e66-90cd-57fbde5fae70", "name": "", "x": 38.68186286213555, "y": -122.49395729632428, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6912a245-ac1c-4ddd-b021-3bc35cbbe2c5", "name": "p1rdt178", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ceeea650-e1b4-4e66-90cd-57fbde5fae70"}}}}, {"uuid": "365d0a90-7e2b-4a3a-b6cb-9ec8a40f3ee9", "name": "", "x": 38.65563774049388, "y": -122.48693753355442, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3f91816-7c3f-4fc7-98a5-6dee55e52e9f", "name": "p1rdt8105", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "365d0a90-7e2b-4a3a-b6cb-9ec8a40f3ee9"}}}}, {"uuid": "5275819a-01e1-4e57-8757-365b836edff4", "name": "", "x": 38.65332887399879, "y": -122.4877199764791, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f2c69fef-4afb-4bb3-9828-096b812de54a", "name": "p1rdt8111", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5275819a-01e1-4e57-8757-365b836edff4"}}}}, {"uuid": "d6c9dab0-2688-471e-9207-5a682545447e", "name": "", "x": 38.65397853262116, "y": -122.48734763535352, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "37229b7c-80a2-4d01-af6a-818bdfcc1f54", "name": "p1rdt8105-p1rdt8111x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d6c9dab0-2688-471e-9207-5a682545447e"}}}}, {"uuid": "0cd3484e-7c70-4cad-97ef-8a3cfa794239", "name": "", "x": 38.653298743960605, "y": -122.48786735210962, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fc34073b-94f6-4c75-8144-8f624bac9cc7", "name": "p1rdt8146", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0cd3484e-7c70-4cad-97ef-8a3cfa794239"}}}}, {"uuid": "10dac104-0d6e-41d9-8fc3-8f17a40b3a12", "name": "", "x": 38.65338804911886, "y": -122.48767001324168, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9929e0d4-3e33-4f5f-b718-6a629cc52242", "name": "p1rdt8111-p1rdt8138xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10dac104-0d6e-41d9-8fc3-8f17a40b3a12"}}}}, {"uuid": "0e5fd983-d874-4f22-ad29-f0f286977194", "name": "", "x": 38.65220693629279, "y": -122.48673933307626, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3a54311-da27-45d7-95c3-eee07761fbe4", "name": "p1rdt8111-p1rdt8138x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0e5fd983-d874-4f22-ad29-f0f286977194"}}}}, {"uuid": "fa457226-617f-4a99-b897-6225df98cda6", "name": "", "x": 38.706834415392834, "y": -122.42490821272983, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b801037a-e1bb-4c5c-8d18-ed285c8c1d3b", "name": "p1rdt251", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa457226-617f-4a99-b897-6225df98cda6"}}}}, {"uuid": "e5389bd2-8ce8-4204-97bd-aee05bb56864", "name": "", "x": 38.70723865207442, "y": -122.42480038439254, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "69b2ee46-ab5f-48c8-a26b-170ed2b57fcb", "name": "p1rdt252", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e5389bd2-8ce8-4204-97bd-aee05bb56864"}}}}, {"uuid": "39cabe12-2278-40ba-9afa-b474d3d17fae", "name": "", "x": 38.70153411123505, "y": -122.42253878409483, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3dfe357-889d-42e0-a59a-821c9f843456", "name": "p1rdt446", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "39cabe12-2278-40ba-9afa-b474d3d17fae"}}}}, {"uuid": "13201431-68c1-4d67-ab30-848923d4ecd2", "name": "", "x": 38.696509390287886, "y": -122.37572644565952, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2cf3136f-6dbe-4ed7-b9cb-e9f73b191f76", "name": "p1rdt481", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "13201431-68c1-4d67-ab30-848923d4ecd2"}}}}, {"uuid": "bb919fde-343d-4af8-b649-1a441fcbe691", "name": "", "x": 38.69562927890001, "y": -122.37574956469108, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a180b972-cf0e-4a2e-9bcf-a0ad90bb3d83", "name": "p1rdt468", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bb919fde-343d-4af8-b649-1a441fcbe691"}}}}, {"uuid": "116b3e5d-3798-43ce-a998-c53f4ba9e37b", "name": "", "x": 38.696842869414894, "y": -122.37573504621221, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c39140c6-8892-480a-81b9-738c67ed1591", "name": "p1rdt475", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "116b3e5d-3798-43ce-a998-c53f4ba9e37b"}}}}, {"uuid": "ee055b10-cabe-4d1d-8c63-0991b1e0c92a", "name": "", "x": 38.697374719659294, "y": -122.37576492139411, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fc35f44e-d8d9-41d0-b014-caa3d8d7a91e", "name": "p1rdt461", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ee055b10-cabe-4d1d-8c63-0991b1e0c92a"}}}}, {"uuid": "ec600ace-eeeb-4966-b6d6-37f79e672b78", "name": "", "x": 38.69825572660699, "y": -122.37579303954152, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2eba354c-f4bf-4c49-a8ad-998ab9489e5a", "name": "p1rdt478", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ec600ace-eeeb-4966-b6d6-37f79e672b78"}}}}, {"uuid": "84847f25-821b-400e-a799-cd3cf8fa9ba5", "name": "", "x": 38.69843582959593, "y": -122.37576847475998, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a94f7afe-e8b0-4b24-8196-6b05e98c3830", "name": "p1rdt465", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "84847f25-821b-400e-a799-cd3cf8fa9ba5"}}}}, {"uuid": "b3af6a2d-b395-43bc-805c-a33d0eac214e", "name": "", "x": 38.699753883698804, "y": -122.37577873918647, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0fa474a3-1d6b-454b-9170-6a8d13789c43", "name": "p1rdt488", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b3af6a2d-b395-43bc-805c-a33d0eac214e"}}}}, {"uuid": "bea7aa80-5487-4162-a59d-41c01b796663", "name": "", "x": 38.699988606794975, "y": -122.37585719796019, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7637cfdb-6a14-4313-95d4-e25beba178f3", "name": "p1rdt463", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bea7aa80-5487-4162-a59d-41c01b796663"}}}}, {"uuid": "d0ae0a33-8d9d-4e46-baff-4744dbc33df5", "name": "", "x": 38.701244304283534, "y": -122.3764327877571, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7627cbc6-c54a-432b-8cba-59e448f6d45a", "name": "p1rdt82", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d0ae0a33-8d9d-4e46-baff-4744dbc33df5"}}}}, {"uuid": "feb8f7d0-ddd9-49a4-9035-25a0f5fa1802", "name": "", "x": 38.701568593856685, "y": -122.37703593173678, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "36bfd1f1-80ca-4b7d-a68b-9aa77ceff96e", "name": "p1rdt78", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "feb8f7d0-ddd9-49a4-9035-25a0f5fa1802"}}}}, {"uuid": "61ff3521-9b61-4365-b8d2-19db719ca287", "name": "", "x": 38.70158095287149, "y": -122.37746615460954, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6fc415bc-f457-4e9f-bbd4-783a71b67ad6", "name": "p1rdt85", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "61ff3521-9b61-4365-b8d2-19db719ca287"}}}}, {"uuid": "8dc7b52a-7147-455e-9b0a-451e50e06055", "name": "", "x": 38.701575510504455, "y": -122.37770642721351, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "063e25be-2abb-49ae-b459-ddd08ba93bb3", "name": "p1rdt81", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8dc7b52a-7147-455e-9b0a-451e50e06055"}}}}, {"uuid": "f44e3248-9cf9-47bd-87c6-7258b7bcf930", "name": "", "x": 38.701531800163046, "y": -122.37795980901173, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b32c9763-ddff-435b-a28c-8f65111c6cb2", "name": "p1rdt79", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f44e3248-9cf9-47bd-87c6-7258b7bcf930"}}}}, {"uuid": "8e69fd51-7eb9-4fd3-b2d6-8a48a810d9a3", "name": "", "x": 38.70139571168677, "y": -122.37841744526864, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dfbb212a-9882-4468-86ac-578c93fde1d8", "name": "p1rdt76", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8e69fd51-7eb9-4fd3-b2d6-8a48a810d9a3"}}}}, {"uuid": "28739721-e132-4b04-86a9-56f6ea3da7da", "name": "", "x": 38.70130561638834, "y": -122.3796880720142, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7c543753-fa26-41df-b7a6-3664395c0d45", "name": "p1rdt31", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "28739721-e132-4b04-86a9-56f6ea3da7da"}}}}, {"uuid": "62463952-0717-41bf-9839-1f1550b7af30", "name": "", "x": 38.70185707821067, "y": -122.38044898464344, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e8dcdfef-b40e-4f1c-9b7c-e84846f68c5a", "name": "p1rdt36", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "62463952-0717-41bf-9839-1f1550b7af30"}}}}, {"uuid": "9101c6b5-0c1a-49cf-a987-2070793803fa", "name": "", "x": 38.702744402653344, "y": -122.38060588011899, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "834e959c-8ee6-4fff-b1fc-54c20fc0f20b", "name": "p1rdt32", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9101c6b5-0c1a-49cf-a987-2070793803fa"}}}}, {"uuid": "f4a0f3e7-a651-456a-8d40-60652fb7afc2", "name": "", "x": 38.70315433826527, "y": -122.38036878848187, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "80331f15-8b31-454c-a289-49cb79923252", "name": "p1rdt234", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f4a0f3e7-a651-456a-8d40-60652fb7afc2"}}}}, {"uuid": "2d354866-5878-4547-971d-7695b52967f8", "name": "", "x": 38.70342202813448, "y": -122.37754091771487, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8f5ed5d5-93fc-4f3c-a78b-df7019863b67", "name": "p1rdt233", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2d354866-5878-4547-971d-7695b52967f8"}}}}, {"uuid": "ff295c7d-9e68-4562-91ff-1c05b39881db", "name": "", "x": 38.70364344183274, "y": -122.37626641561926, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "445f61a4-8045-4558-a3c1-bb44336737ec", "name": "p1rdt485", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ff295c7d-9e68-4562-91ff-1c05b39881db"}}}}, {"uuid": "5593c229-b3c9-4d0d-bc4f-0be1328a3af8", "name": "", "x": 38.70340510620564, "y": -122.37837704887761, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "190d6c51-94b6-462e-8fee-cce57f1ab66d", "name": "p1rdt236", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5593c229-b3c9-4d0d-bc4f-0be1328a3af8"}}}}, {"uuid": "673128da-caab-4282-9357-c1d62f2c2ece", "name": "", "x": 38.70289903823247, "y": -122.38150952694326, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "14b85850-d83e-4a5e-83c3-ccb485bb85aa", "name": "p1rdt235", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "673128da-caab-4282-9357-c1d62f2c2ece"}}}}, {"uuid": "a374df4b-0d29-44b7-9bac-64b8948c031e", "name": "", "x": 38.70241528605291, "y": -122.38205420706528, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4fa95a19-0e0a-49b3-bb86-7103fbaa4110", "name": "p1rdt30", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a374df4b-0d29-44b7-9bac-64b8948c031e"}}}}, {"uuid": "27886ea0-4c87-411a-b113-73a096f62fda", "name": "", "x": 38.70180761889256, "y": -122.38302545203672, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "edc22f66-e919-448e-b990-76033c281d43", "name": "p1rdt35", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "27886ea0-4c87-411a-b113-73a096f62fda"}}}}, {"uuid": "236076ef-b7c1-4fb9-8263-b3a045928901", "name": "", "x": 38.70163145569769, "y": -122.3837974760483, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1e9f4b13-5fb5-46b2-9258-83582d47d61a", "name": "p1rdt84", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "236076ef-b7c1-4fb9-8263-b3a045928901"}}}}, {"uuid": "7b7eef78-375f-456d-852b-00b1d572d559", "name": "", "x": 38.70166339444126, "y": -122.38472871487578, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f55e4012-a11d-4883-baac-9c013aff6058", "name": "p1rdt33", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7b7eef78-375f-456d-852b-00b1d572d559"}}}}, {"uuid": "247189ff-cc8a-46c5-a8c4-302aa83aca0a", "name": "", "x": 38.7017418716262, "y": -122.38534278443267, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a01c83d1-4adb-4b2a-8de3-441d7c1dd054", "name": "p1rdt39", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "247189ff-cc8a-46c5-a8c4-302aa83aca0a"}}}}, {"uuid": "bd8ee146-d20a-4486-a4a6-8cc95bd84b7d", "name": "", "x": 38.701720915150304, "y": -122.38552827095313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dc531967-1a7b-4424-83ee-e1131c6fd94c", "name": "p1rdt73", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bd8ee146-d20a-4486-a4a6-8cc95bd84b7d"}}}}, {"uuid": "93962e5e-5dec-4444-8f0a-d3dcffea81d1", "name": "", "x": 38.70178214782518, "y": -122.38611126603591, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "510ea93c-7dd1-4fa3-ba3f-6c362856c7c1", "name": "p1rdt75", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "93962e5e-5dec-4444-8f0a-d3dcffea81d1"}}}}, {"uuid": "31ad3b66-1fa1-490b-bef3-43e3c128eca3", "name": "", "x": 38.70181286232661, "y": -122.3868125146921, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0aa0b7c2-9d55-4faf-8778-76a6f23bcf3e", "name": "p1rdt83", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "31ad3b66-1fa1-490b-bef3-43e3c128eca3"}}}}, {"uuid": "526cccc9-2c2a-4ed8-afcb-3a615e136d3a", "name": "", "x": 38.70215867171945, "y": -122.38789186166865, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b03f8e29-a5b2-4bed-b68c-219276674b6a", "name": "p1rdt80", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "526cccc9-2c2a-4ed8-afcb-3a615e136d3a"}}}}, {"uuid": "be8ad268-a3cf-443d-a0ec-9b264dda0a90", "name": "", "x": 38.697976462001364, "y": -122.39194580684853, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6e26e5dc-8c98-4fcd-b125-3265eb00f3f2", "name": "p1rdt263", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be8ad268-a3cf-443d-a0ec-9b264dda0a90"}}}}, {"uuid": "e49f82ab-a211-49e8-85c6-8633476c0695", "name": "", "x": 38.69710687368567, "y": -122.39904337583427, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "add5e39f-f02e-4a61-a156-d5721cec25d5", "name": "p1rdt277", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e49f82ab-a211-49e8-85c6-8633476c0695"}}}}, {"uuid": "78223a48-666e-4fcb-bebe-4311d1ecde6b", "name": "", "x": 38.69810207651738, "y": -122.40314189875019, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "186ffdfe-2346-4218-bd6b-b813ea6b3b62", "name": "p1rdt276", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "78223a48-666e-4fcb-bebe-4311d1ecde6b"}}}}, {"uuid": "01232a55-73d4-431f-b4e2-ab26730f7c11", "name": "", "x": 38.690000449751984, "y": -122.37232330919996, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9396562e-4f87-4e04-b248-502b851fe19e", "name": "p1rdt69", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "01232a55-73d4-431f-b4e2-ab26730f7c11"}}}}, {"uuid": "c3618ba1-cc9e-482c-b16e-58f3afed5c90", "name": "", "x": 38.689693582568, "y": -122.3712823494636, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b1bf1493-fb0d-40b4-8953-42e851a128d1", "name": "p1rdt44-p1rdt69x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c3618ba1-cc9e-482c-b16e-58f3afed5c90"}}}}, {"uuid": "abafd7f4-0cb8-4405-b252-6d3fa278f0eb", "name": "", "x": 38.68937758378194, "y": -122.37014905131693, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d9ee2ff-e2bc-4d76-b173-5ba5cc48c9b3", "name": "p1rdt44", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "abafd7f4-0cb8-4405-b252-6d3fa278f0eb"}}}}, {"uuid": "03aced16-e52e-475b-a740-04f3b1bf820b", "name": "", "x": 38.69011879726304, "y": -122.37274288833332, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f5b5b3ae-f657-4fd4-a311-ab1dbe9d749e", "name": "p1rdt41", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "03aced16-e52e-475b-a740-04f3b1bf820b"}}}}, {"uuid": "36d91d90-2790-49d6-b119-47c834f4234b", "name": "", "x": 38.690503780808164, "y": -122.3733294899771, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5a898f4c-f522-4e69-be4a-e935e339e011", "name": "p1rdt54", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "36d91d90-2790-49d6-b119-47c834f4234b"}}}}, {"uuid": "aaa1d980-d87f-4d7b-ac4e-4b123d9d1355", "name": "", "x": 38.690543520806486, "y": -122.37401904570497, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a778171c-22a1-4320-9e3c-43888d734e34", "name": "p1rdt42", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aaa1d980-d87f-4d7b-ac4e-4b123d9d1355"}}}}, {"uuid": "947f010e-99dd-41e2-96b2-bffab8e65938", "name": "", "x": 38.69014061173149, "y": -122.37513434619457, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "29a79372-9c75-4a9c-81df-a7491b87e58a", "name": "p1rdt45", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "947f010e-99dd-41e2-96b2-bffab8e65938"}}}}, {"uuid": "b407de02-85af-4ee9-8cd1-d1819848c2a8", "name": "", "x": 38.69057727021838, "y": -122.39183596993689, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "12451cbc-eb14-4814-b274-12eb2241c78a", "name": "p1rdt150", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b407de02-85af-4ee9-8cd1-d1819848c2a8"}}}}, {"uuid": "20710a8e-91b2-4c39-a742-bbc05da3aea2", "name": "", "x": 38.690031528872375, "y": -122.37717801542972, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "666bb367-692a-4127-8f77-d86d651768a1", "name": "p1rdt150-p1rdt45x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "20710a8e-91b2-4c39-a742-bbc05da3aea2"}}}}, {"uuid": "8ae76df5-4eda-4ab4-b4a6-5a6cc3bc0572", "name": "", "x": 38.694133300872906, "y": -122.39690517522077, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ba0ef4a3-43ba-469b-8ce8-ca7a5a984071", "name": "p1rdt260", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8ae76df5-4eda-4ab4-b4a6-5a6cc3bc0572"}}}}, {"uuid": "d3ad0f96-fc3e-4803-a9e7-5fb27f447339", "name": "", "x": 38.693518695228036, "y": -122.39600590196753, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e885b3e5-18fb-4454-b8e7-d82b4c72f6e8", "name": "p1rdt150-p1rdt260x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d3ad0f96-fc3e-4803-a9e7-5fb27f447339"}}}}, {"uuid": "3163f4ff-97fe-45fc-a29c-50928b93536f", "name": "", "x": 38.69620897416254, "y": -122.40296066033352, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "153bb615-5ee5-4eec-bcf7-94ea0098aeb6", "name": "p1rdt279", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3163f4ff-97fe-45fc-a29c-50928b93536f"}}}}, {"uuid": "a8a933b7-550e-458e-a813-a122f7e87ffb", "name": "", "x": 38.69807607310296, "y": -122.40309926707015, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7140d97e-416e-47ec-9f86-46ad6f9abece", "name": "p1rdt276-p1rdt279x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8a933b7-550e-458e-a813-a122f7e87ffb"}}}}, {"uuid": "aa93ecf8-6317-4e7e-8477-1c893b5d069b", "name": "", "x": 38.69819542243506, "y": -122.40314157925388, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c3ca9bee-26b0-4ef4-8555-6494ffdd6a17", "name": "p1rdt237-p1rdt276x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aa93ecf8-6317-4e7e-8477-1c893b5d069b"}}}}, {"uuid": "0ca3bc30-a32a-4240-89b1-4f3e26a789a5", "name": "", "x": 38.69933414700199, "y": -122.4089172598197, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "767b59ef-ecd9-4b17-8233-2033a02b2971", "name": "p1rdt237-p1rdt276xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0ca3bc30-a32a-4240-89b1-4f3e26a789a5"}}}}, {"uuid": "3781b958-1ce3-4d50-b11e-7a414f9249c8", "name": "", "x": 38.70123224209162, "y": -122.42082954062212, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "11571d26-573f-49f7-99fd-828dde97afd8", "name": "p1rdt445", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3781b958-1ce3-4d50-b11e-7a414f9249c8"}}}}, {"uuid": "597b89b3-1ee6-4948-af20-fb9177ddd8a9", "name": "", "x": 38.69940195487717, "y": -122.41580111174017, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b8c8b8f8-7a41-4d16-b509-2d7c7af9509d", "name": "p1rdt237", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "597b89b3-1ee6-4948-af20-fb9177ddd8a9"}}}}, {"uuid": "6c603289-21a7-43aa-9f84-f41ba7f6e016", "name": "", "x": 38.701258982520905, "y": -122.42203851637785, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "10620dcc-049c-4417-b4ac-922a56c0d4a2", "name": "p1rdt438", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c603289-21a7-43aa-9f84-f41ba7f6e016"}}}}, {"uuid": "cc52b747-000a-4eb9-8b06-9966684ef16d", "name": "", "x": 38.689358814642475, "y": -122.44266212701238, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e71eb2d5-cd10-498d-b9eb-ae337b2f8af6", "name": "p1rdt28", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc52b747-000a-4eb9-8b06-9966684ef16d"}}}}, {"uuid": "564731ca-f9e0-45c3-9794-cebe993202f6", "name": "", "x": 38.68721403983049, "y": -122.44207560107604, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b238dc5-7d8e-4b2d-8449-4dc212d7d227", "name": "p1rdt29", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "564731ca-f9e0-45c3-9794-cebe993202f6"}}}}, {"uuid": "9d4e97bd-a73c-4ed1-aad4-1c56fcfeb7f5", "name": "", "x": 38.68513046534505, "y": -122.45203222088253, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b07c4a6-39a7-4521-bce7-3f1ca0ff4a66", "name": "p1rdt335", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9d4e97bd-a73c-4ed1-aad4-1c56fcfeb7f5"}}}}, {"uuid": "74004cc2-1c07-40eb-b690-9af1a3df1329", "name": "", "x": 38.672940788437906, "y": -122.46748581101485, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d2efeaf5-2055-4718-a064-7c5e00b7d87d", "name": "p1rdt335-p1rdt419x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "74004cc2-1c07-40eb-b690-9af1a3df1329"}}}}, {"uuid": "bd6d72a5-0be7-43d2-8bdd-a587714676de", "name": "", "x": 38.670797093100916, "y": -122.46774549226095, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4cf05060-0a39-49a9-a761-79fb136e2965", "name": "p1rdt420", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bd6d72a5-0be7-43d2-8bdd-a587714676de"}}}}, {"uuid": "a7442dd9-11f1-4aa7-b011-7fe9acac7b86", "name": "", "x": 38.67291356677607, "y": -122.46744017800017, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "81cfd2a2-295c-4b73-abba-05ffee810523", "name": "p1rdt419", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a7442dd9-11f1-4aa7-b011-7fe9acac7b86"}}}}, {"uuid": "31607d9b-e1df-4994-b05a-19e19b826848", "name": "", "x": 38.66669420046755, "y": -122.46979269819516, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2eb3d4eb-71fc-46f3-b588-d223568c411c", "name": "p1rdt8167", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "31607d9b-e1df-4994-b05a-19e19b826848"}}}}, {"uuid": "755607de-9ddc-4da7-90ee-fa14c364aa50", "name": "", "x": 38.66526952797366, "y": -122.47022403577644, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3c93a476-4ad5-41cd-a07b-e2ccc9ef2c3b", "name": "p1rdt8180", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "755607de-9ddc-4da7-90ee-fa14c364aa50"}}}}, {"uuid": "ba2d9fb2-095f-4bb5-8b20-417d9d825944", "name": "", "x": 38.66479901416412, "y": -122.46771598894871, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f6bdb2cf-9373-4d56-a5f9-cb8fa9c67e55", "name": "p1rdt8169", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ba2d9fb2-095f-4bb5-8b20-417d9d825944"}}}}, {"uuid": "1859b7c8-60c3-43f1-b2f2-20c000be300e", "name": "", "x": 38.66152380322448, "y": -122.47383733708416, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "498a07ee-e12b-459a-a01f-f663a4a8428a", "name": "p1rdt8174-p1rdt8180x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1859b7c8-60c3-43f1-b2f2-20c000be300e"}}}}, {"uuid": "91f2ce3d-3736-4c91-8287-a517bda95203", "name": "", "x": 38.6604983255136, "y": -122.47346682060977, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8997dae6-8970-4762-98e9-0617375633d6", "name": "p1rdt8195", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "91f2ce3d-3736-4c91-8287-a517bda95203"}}}}, {"uuid": "d9edddcb-9fa1-475f-9bf6-503a8412b109", "name": "", "x": 38.66147939586647, "y": -122.47384646091422, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6b0f9433-e0a3-458a-8687-c9cf38d0bbb3", "name": "p1rdt8174", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d9edddcb-9fa1-475f-9bf6-503a8412b109"}}}}, {"uuid": "cb97c63c-d7ff-485c-9dfe-4e26ebff9985", "name": "", "x": 38.658272650826795, "y": -122.47501655241358, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "081feb5c-d5d5-405e-85d4-f1dd0916fc3d", "name": "p1rdt7757", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb97c63c-d7ff-485c-9dfe-4e26ebff9985"}}}}, {"uuid": "14c338c8-ab4b-486b-a84b-27dda3b552bc", "name": "", "x": 38.655197924044465, "y": -122.48096925268166, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "68117bef-16c5-40c9-9356-76ef5c056650", "name": "p1rdt5560", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "14c338c8-ab4b-486b-a84b-27dda3b552bc"}}}}, {"uuid": "cd9b5143-5e3c-47a8-8356-96be17119efb", "name": "", "x": 38.6571578603823, "y": -122.47877412021943, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b64b7bd6-06e4-45f7-b987-efc7d09b91f8", "name": "p1rdt5560-p1rdt7757x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cd9b5143-5e3c-47a8-8356-96be17119efb"}}}}, {"uuid": "7a8878fb-4cdc-4fa9-b40d-55bc8657a357", "name": "", "x": 38.6544084693578, "y": -122.48126098888899, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8444c9ea-ff7a-4b0a-9ea6-9c18770565cb", "name": "p1rdt5564", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7a8878fb-4cdc-4fa9-b40d-55bc8657a357"}}}}, {"uuid": "c1427e78-5470-44e6-90f6-405b0dcda489", "name": "", "x": 38.65411176650942, "y": -122.48165516473325, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ad24f98d-f022-4e62-b80b-426052810759", "name": "p1rdt5563", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c1427e78-5470-44e6-90f6-405b0dcda489"}}}}, {"uuid": "ad5db67d-1964-4568-ad89-8f27ba79aa8d", "name": "", "x": 38.65399305368811, "y": -122.48234388532953, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c94489ed-4399-4dab-bab6-02b79f240f63", "name": "p1rdt5557-p1rdt5563x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ad5db67d-1964-4568-ad89-8f27ba79aa8d"}}}}, {"uuid": "b159b55d-cc9f-46ad-bf19-5d08b45496f4", "name": "", "x": 38.65409795953588, "y": -122.48170621590174, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fbc31b75-f942-4bae-8712-f1666d8b7f26", "name": "p1rdt5557-p1rdt5563xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b159b55d-cc9f-46ad-bf19-5d08b45496f4"}}}}, {"uuid": "cbcd009a-0c20-4d15-a018-6b45b447e5a2", "name": "", "x": 38.65386072697981, "y": -122.48298842075683, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "efe7243f-340b-4114-be7c-f7494e78384f", "name": "p1rdt5557-p1rdt5565xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cbcd009a-0c20-4d15-a018-6b45b447e5a2"}}}}, {"uuid": "0a21d5f6-b987-4af0-8cad-052a586d9aaf", "name": "", "x": 38.6540547104338, "y": -122.48228339829146, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bfe92e2e-285d-4c58-8e0b-a462dd73fa41", "name": "p1rdt5557-p1rdt5565x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a21d5f6-b987-4af0-8cad-052a586d9aaf"}}}}, {"uuid": "53b7a282-efd7-49b9-8b4c-e3660d062d2f", "name": "", "x": 38.653744336845875, "y": -122.48342339339821, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8bd0860f-2b3e-4c90-a571-cfc6aa649e5b", "name": "p1rdt5561-p1rdt5565x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "53b7a282-efd7-49b9-8b4c-e3660d062d2f"}}}}, {"uuid": "83fe7a48-cf07-4fea-aee2-6f82ef002e17", "name": "", "x": 38.653922384064785, "y": -122.48292793438009, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bebca5d7-2d4f-4655-a965-9faafd7a8125", "name": "p1rdt5561-p1rdt5565xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "83fe7a48-cf07-4fea-aee2-6f82ef002e17"}}}}, {"uuid": "e16a0510-15af-4338-ad06-536625606dae", "name": "", "x": 38.653656874338274, "y": -122.48382172207613, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "27ab530f-a58e-4113-80f6-63f768910204", "name": "p1rdt5551-p1rdt5561x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e16a0510-15af-4338-ad06-536625606dae"}}}}, {"uuid": "4d8bd976-82f1-4fab-984f-87546cf80006", "name": "", "x": 38.65368267949884, "y": -122.4834838792017, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bf97a458-469e-4609-bb33-97454e7c2b68", "name": "p1rdt5551-p1rdt5561xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d8bd976-82f1-4fab-984f-87546cf80006"}}}}, {"uuid": "0d7f3c2b-6d04-41bd-b92d-4a2665f338a3", "name": "", "x": 38.65357363505309, "y": -122.48418848997771, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d447cf8-7b2b-45f1-8084-6fe4897e1853", "name": "p1rdt5548-p1rdt5551x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0d7f3c2b-6d04-41bd-b92d-4a2665f338a3"}}}}, {"uuid": "bf13386c-86ca-40dc-8ce9-f0367315b4ae", "name": "", "x": 38.65359832142837, "y": -122.48384598170813, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5ec70f12-a676-48cd-b626-34f8d7f6a5bf", "name": "p1rdt5548-p1rdt5551xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bf13386c-86ca-40dc-8ce9-f0367315b4ae"}}}}, {"uuid": "58902d6a-effa-4407-ade5-fc151647b853", "name": "", "x": 38.65344193779202, "y": -122.48465054385285, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "10f43169-4b4b-4dbe-8f09-af72d427d6c7", "name": "p1rdt5548-p1rdt5566xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "58902d6a-effa-4407-ade5-fc151647b853"}}}}, {"uuid": "fa35428d-ad2e-4833-92af-155777d08869", "name": "", "x": 38.65355345327659, "y": -122.48411429646117, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "23163dba-070c-435c-bb90-77be7ded002a", "name": "p1rdt5548-p1rdt5566x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa35428d-ad2e-4833-92af-155777d08869"}}}}, {"uuid": "62505c49-18d7-4dc7-88a2-27afcb42e823", "name": "", "x": 38.65349305461597, "y": -122.48469671958328, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bf619f04-1fa5-4be7-8a76-669b79436d3e", "name": "p1rdt5566-p1rdt5574xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "62505c49-18d7-4dc7-88a2-27afcb42e823"}}}}, {"uuid": "d3ac96ef-09fb-4bae-b143-3a065d9d9ad1", "name": "", "x": 38.65351374951022, "y": -122.48468872832316, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c264e6de-a898-421d-a2fe-ce6548aa477e", "name": "p1rdt5566-p1rdt5574x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d3ac96ef-09fb-4bae-b143-3a065d9d9ad1"}}}}, {"uuid": "06702de2-f8c8-4589-8236-bca704fa692d", "name": "", "x": 38.6521229408726, "y": -122.4867812786121, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "17b633c6-214d-4428-bded-df737f50ffb6", "name": "p1rdt8138", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "06702de2-f8c8-4589-8236-bca704fa692d"}}}}, {"uuid": "0173173b-eac5-4e26-8f41-c21afd87760e", "name": "", "x": 38.65212339039547, "y": -122.48678923108443, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2c8fd701-7842-49c1-b630-7ae1ad49739f", "name": "p1rdt5574-p1rdt8138x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0173173b-eac5-4e26-8f41-c21afd87760e"}}}}, {"uuid": "7596258b-68d1-4f85-b881-4661a9159a6c", "name": "", "x": 38.6534675320259, "y": -122.48473979533868, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e9906676-e9b9-4d51-b1c2-a6b6fe187faa", "name": "p1rdt5574", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7596258b-68d1-4f85-b881-4661a9159a6c"}}}}, {"uuid": "2f74bd6e-72a9-42da-a509-e0390ecfbf81", "name": "", "x": 38.64755444307129, "y": -122.50915596024865, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "63b2f1e6-5e15-4433-85ee-ff7bb7218b96", "name": "p1rdt6488", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2f74bd6e-72a9-42da-a509-e0390ecfbf81"}}}}, {"uuid": "0bbf498a-e4cc-40d6-a250-682263afe9bd", "name": "", "x": 38.647519963483695, "y": -122.50475738860712, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "548ba541-a511-486c-876c-c841a6e482af", "name": "p1rdt6488-p1rdt8138x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0bbf498a-e4cc-40d6-a250-682263afe9bd"}}}}, {"uuid": "e0bc28a4-d366-4769-b729-d481f566e45b", "name": "", "x": 38.653569957917405, "y": -122.48377667700575, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a9dec144-ef2e-44fe-990a-c9d70b740410", "name": "p1rdt5551lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e0bc28a4-d366-4769-b729-d481f566e45b"}}}}, {"uuid": "0edb9ce5-61b9-441c-8a5a-d23c20926863", "name": "", "x": 38.653349320804885, "y": -122.48361706572747, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "82988650-787d-41de-bca7-4f3c08ccad15", "name": "p1rlv11506", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0edb9ce5-61b9-441c-8a5a-d23c20926863"}}}}, {"uuid": "a749a880-49d7-464e-abad-60ef90fb20cf", "name": "", "x": 38.65393253922449, "y": -122.48302660355507, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60dc1291-a843-4abf-bfc6-ff8afc8c0b98", "name": "p1rdt5565lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a749a880-49d7-464e-abad-60ef90fb20cf"}}}}, {"uuid": "edd8090c-62f3-41ba-b6c3-d35d218dc4e9", "name": "", "x": 38.65344458882935, "y": -122.48274295264503, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "176b348f-9ecf-4a82-bdf9-f2e5d5a07af7", "name": "p1rlv11522", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "edd8090c-62f3-41ba-b6c3-d35d218dc4e9"}}}}, {"uuid": "f15e74bc-cd3f-4502-bdbc-ac249f73eea8", "name": "", "x": 38.65413728795049, "y": -122.4816120875077, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0a150dd3-61a4-4df9-90e2-6c72f80af819", "name": "p1rdt5563lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f15e74bc-cd3f-4502-bdbc-ac249f73eea8"}}}}, {"uuid": "4ba1e7ab-c731-42a2-b1cf-1a4a3eee3337", "name": "", "x": 38.65368296548394, "y": -122.48162646334242, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "22054033-4e69-41b0-b321-a4d086d20574", "name": "p1rlv11520", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ba1e7ab-c731-42a2-b1cf-1a4a3eee3337"}}}}, {"uuid": "2721271a-309e-4478-a9f3-411791dd008f", "name": "", "x": 38.707239856986014, "y": -122.42485436421835, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c5fd6466-e740-4f06-a842-798195d62154", "name": "p1rdt252lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2721271a-309e-4478-a9f3-411791dd008f"}}}}, {"uuid": "8c301039-3b06-4026-9cfd-61173d74a637", "name": "", "x": 38.70723070261674, "y": -122.4249071150479, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a23f97bc-e7ef-4f64-9e64-314f4a4e17d8", "name": "p1rlv440", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8c301039-3b06-4026-9cfd-61173d74a637"}}}}, {"uuid": "beb8a8dd-d1ae-4c46-a0b8-9164b1204cd1", "name": "", "x": 38.65363370971865, "y": -122.48373653900416, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "514ad102-b590-4ad8-a258-2b6fa8dcbeb1", "name": "p1rdt5551-p1rdt5568x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "beb8a8dd-d1ae-4c46-a0b8-9164b1204cd1"}}}}, {"uuid": "5fd03be4-748d-4158-a92d-24b0cc0a9305", "name": "", "x": 38.65350635684874, "y": -122.48421628994025, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25ee6008-ddbc-4e7b-8a57-ff38c16368a2", "name": "p1rdt5548-p1rdt5577x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5fd03be4-748d-4158-a92d-24b0cc0a9305"}}}}, {"uuid": "bf563631-9bac-4a2c-9536-752dae925812", "name": "", "x": 38.65213674275478, "y": -122.48364605819339, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1c8b424-4509-4fd2-93e2-4fd54f6cf49a", "name": "p1rdt5577", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bf563631-9bac-4a2c-9536-752dae925812"}}}}, {"uuid": "406f41ee-91ce-4a71-849a-80eed4ccd2c4", "name": "", "x": 38.65403765024386, "y": -122.48233644072755, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cca8918c-30e6-4619-a5e0-8c0d3451f9c4", "name": "p1rdt5557", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "406f41ee-91ce-4a71-849a-80eed4ccd2c4"}}}}, {"uuid": "bbda2575-698a-42f3-b5bf-3a83b99b842a", "name": "", "x": 38.65390532358046, "y": -122.48298097656864, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b5e479d3-aae0-47b8-b707-bad1191df1e7", "name": "p1rdt5565", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bbda2575-698a-42f3-b5bf-3a83b99b842a"}}}}, {"uuid": "c0e900d1-a01a-4a5a-9d85-1a6d12778a63", "name": "", "x": 38.65372727613462, "y": -122.48347643534002, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "756f6cd8-301b-4fac-b414-d72853616c6e", "name": "p1rdt5561", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c0e900d1-a01a-4a5a-9d85-1a6d12778a63"}}}}, {"uuid": "ddd5810d-928e-4fa9-96db-426ae8d4092e", "name": "", "x": 38.653615927095316, "y": -122.48379127781236, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5f7fed4f-197e-4a79-97e5-df595377736b", "name": "p1rdt5551", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ddd5810d-928e-4fa9-96db-426ae8d4092e"}}}}, {"uuid": "99b54ad7-1ddb-4d8c-8305-c45ad70177b3", "name": "", "x": 38.653529895117565, "y": -122.48416522717811, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6bf1b63d-fbce-42f8-9948-2e09bfa67409", "name": "p1rdt5548", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "99b54ad7-1ddb-4d8c-8305-c45ad70177b3"}}}}, {"uuid": "25286f23-9994-4df7-a510-04d00e26e939", "name": "", "x": 38.65348653464999, "y": -122.48464310081867, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9fed9557-b170-4817-8bd8-efc3b9f7c982", "name": "p1rdt5566", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "25286f23-9994-4df7-a510-04d00e26e939"}}}}, {"uuid": "1f82ec4b-389f-44b2-8e92-0331097de9d4", "name": "", "x": 38.65857449295584, "y": -122.51047390361627, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16ace27f-f5fa-4fd1-840e-8cae55dbe1b2", "name": "p1rdt383-p1rdt7300x_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1f82ec4b-389f-44b2-8e92-0331097de9d4"}}}}, {"uuid": "11d5fb2d-a11f-4cca-a32d-a54a006ec224", "name": "", "x": 38.755774152251824, "y": -122.36924141377668, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e6b5c947-b0c5-4e20-bd74-bf847bdacd30", "name": "p1rdt181_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "11d5fb2d-a11f-4cca-a32d-a54a006ec224"}}}}, {"uuid": "a94365ec-ba7e-41ad-9b88-27ea9076b835", "name": "", "x": 38.76763103931847, "y": -122.38059245720176, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "99615f32-0614-4c23-a1e1-b3e8e5688cce", "name": "p1rdt66", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a94365ec-ba7e-41ad-9b88-27ea9076b835"}}}}, {"uuid": "8e2b886e-e1fc-41ea-a1e8-76febb13f1e2", "name": "", "x": 38.73066670610679, "y": -122.39985796643494, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "71abd5f1-ca61-4754-a2ef-7b5d4e635f99", "name": "p1rdt181-p1rdt297x_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8e2b886e-e1fc-41ea-a1e8-76febb13f1e2"}}}}, {"uuid": "4d02be35-fcba-456e-b90e-38db765a0ac1", "name": "", "x": 38.73098682493839, "y": -122.41321244241928, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b0fad7ee-b65c-460c-94ca-fe9546a5b140", "name": "p1rdt270-p1rdt298x_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d02be35-fcba-456e-b90e-38db765a0ac1"}}}}, {"uuid": "639ab63c-d85d-49e0-bfb2-74b043b6dcba", "name": "", "x": 38.68766311446792, "y": -122.34290029588801, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b8064f1d-11b7-4913-8344-175c1388be3e", "name": "p1rdt16604-p1rdt257x_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "639ab63c-d85d-49e0-bfb2-74b043b6dcba"}}}}, {"uuid": "d63106f2-69d0-425e-9c68-7a00109bd753", "name": "", "x": 38.6006266312945, "y": -122.52427556411426, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e2131350-dc34-4d8d-8c9f-c29e25bc654c", "name": "p1rdt7711", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d63106f2-69d0-425e-9c68-7a00109bd753"}}}}, {"uuid": "15ce6336-bc93-4d4a-8034-cf23d75b7464", "name": "", "x": 38.60058489010104, "y": -122.52426789727744, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "64b60527-0853-4973-8d7a-78ba5e377799", "name": "p1rdt7711lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "15ce6336-bc93-4d4a-8034-cf23d75b7464"}}}}, {"uuid": "b247caad-f974-4017-a99d-5bfa5bf2b928", "name": "", "x": 38.600468680548644, "y": -122.5242248045325, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3ed6276c-a57b-40be-a1f1-34aaaba0ac28", "name": "p1rlv16411", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b247caad-f974-4017-a99d-5bfa5bf2b928"}}}}, {"uuid": "a07a22f5-d840-47dd-9319-457197a96756", "name": "", "x": 38.60059554402563, "y": -122.52439622804972, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e0a92e79-0ca2-4a10-9050-9e8d7442b019", "name": "p1rlv20414", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a07a22f5-d840-47dd-9319-457197a96756"}}}}, {"uuid": "6eedbed5-071e-429f-9cb3-c1cf4e13a452", "name": "", "x": 38.59743372341483, "y": -122.52848624702995, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "439728c5-fee5-4dfa-9894-261ba6c40e95", "name": "p1rdt8473lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6eedbed5-071e-429f-9cb3-c1cf4e13a452"}}}}, {"uuid": "8f49bd92-9100-4688-a6c3-8c7dab784aa0", "name": "", "x": 38.59755648297391, "y": -122.52834367013348, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3c1eac45-623a-4f0a-874d-a4b56a8e2ea7", "name": "p1rlv18169", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8f49bd92-9100-4688-a6c3-8c7dab784aa0"}}}}, {"uuid": "c750bbe3-7c46-4b17-8dda-052506550e67", "name": "", "x": 38.59726926605651, "y": -122.52863263826859, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "949f4cce-f321-4bf0-830b-489edc9964c7", "name": "p1rlv18194", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c750bbe3-7c46-4b17-8dda-052506550e67"}}}}, {"uuid": "c7fc9e30-46b9-4818-b666-3885d4c69c23", "name": "", "x": 38.5973486590682, "y": -122.53115453060339, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35f6f747-811d-4fe2-a9c7-991248572c74", "name": "p1rdt6028lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c7fc9e30-46b9-4818-b666-3885d4c69c23"}}}}, {"uuid": "d612deb0-ae01-4e0e-8f3c-4dc7320ec9aa", "name": "", "x": 38.597359644970844, "y": -122.53094024225281, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "72f659b6-d302-4887-a2f6-1a477ad3324c", "name": "p1rlv12518", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d612deb0-ae01-4e0e-8f3c-4dc7320ec9aa"}}}}, {"uuid": "f82d5b04-ca0c-4334-a89a-1e8dcc3def3c", "name": "", "x": 38.597740803009394, "y": -122.53160381152783, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f9660b80-0fce-4be4-b541-743d5811133c", "name": "p1rlv12528", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f82d5b04-ca0c-4334-a89a-1e8dcc3def3c"}}}}, {"uuid": "0d020d98-a846-403c-9afb-ee0db1c7029d", "name": "", "x": 38.59730635717321, "y": -122.53113580939358, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8796d817-aad6-4d22-b3d4-baf8a686c9df", "name": "p1rlv12534", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0d020d98-a846-403c-9afb-ee0db1c7029d"}}}}, {"uuid": "7e1a9607-6da1-4730-9899-d1a9821d629a", "name": "", "x": 38.597059503153865, "y": -122.53096119189571, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e89452f3-ce44-46d3-a259-f66044e01c2c", "name": "p1rlv12536", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7e1a9607-6da1-4730-9899-d1a9821d629a"}}}}, {"uuid": "64714c99-eb77-45de-8558-c4ccb0182909", "name": "", "x": 38.598068610661386, "y": -122.54952501293569, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ddf38626-1223-429f-a903-98f1c975020b", "name": "p1rdt9478lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "64714c99-eb77-45de-8558-c4ccb0182909"}}}}, {"uuid": "f8becd39-60a8-4e1e-9c22-bb224d6ad808", "name": "", "x": 38.59809415769325, "y": -122.54948199323535, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cebe1b53-cca6-4bd4-a9f0-616ffb9750b3", "name": "p1rlv20501", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f8becd39-60a8-4e1e-9c22-bb224d6ad808"}}}}, {"uuid": "eba7b3a6-8113-470f-a84e-d5f0ed18ecb5", "name": "", "x": 38.59772028985937, "y": -122.55034252722092, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3e2630e1-a215-4740-9327-fa004e89863d", "name": "p1rdt6232lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eba7b3a6-8113-470f-a84e-d5f0ed18ecb5"}}}}, {"uuid": "6d3aa3aa-641b-4303-8721-8f50561f013f", "name": "", "x": 38.59770645245217, "y": -122.5503935254409, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "df3aae83-f4b0-4db2-9301-dff1664ac23e", "name": "p1rlv12985", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6d3aa3aa-641b-4303-8721-8f50561f013f"}}}}, {"uuid": "abda40da-fda1-41de-a3fa-a0c7ca091e4f", "name": "", "x": 38.59805477361372, "y": -122.54957601155624, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c49b6e87-5834-4e7e-a64c-b4ec0f7d4995", "name": "p1rdt9478", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "abda40da-fda1-41de-a3fa-a0c7ca091e4f"}}}}, {"uuid": "7465d552-f9fd-4c18-bbcb-046e2214089f", "name": "", "x": 38.59774583719626, "y": -122.55029950801654, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b59ad93a-cca2-4a77-8515-a645ddd2a320", "name": "p1rdt6232", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7465d552-f9fd-4c18-bbcb-046e2214089f"}}}}, {"uuid": "a45aed2c-9785-4267-b6c9-93de8a2eb205", "name": "", "x": 38.59739040278303, "y": -122.53116220049235, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e39cb1db-d6a6-4b6c-bc73-920e0c34c292", "name": "p1rdt6028", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a45aed2c-9785-4267-b6c9-93de8a2eb205"}}}}, {"uuid": "47744c39-d0fa-4c6b-8dd3-2d10ae71edc2", "name": "", "x": 38.602431647117115, "y": -122.53503011701754, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f77960bf-f017-400c-b505-16e7c2e90fe7", "name": "p1rdt6028_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "47744c39-d0fa-4c6b-8dd3-2d10ae71edc2"}}}}, {"uuid": "73fddd2a-9c61-4c25-bfc8-9b3588a86e04", "name": "", "x": 38.597391979534734, "y": -122.52847857868831, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b3a83211-0829-4e2c-b618-3f1fcaba3e87", "name": "p1rdt8473", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "73fddd2a-9c61-4c25-bfc8-9b3588a86e04"}}}}, {"uuid": "d47488e2-6469-4439-a236-085f77265a79", "name": "", "x": 38.59407749157057, "y": -122.52505662658886, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c330731a-fd2c-40c7-8fce-94f7e17cf6d9", "name": "p1rdt8493lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d47488e2-6469-4439-a236-085f77265a79"}}}}, {"uuid": "c5d6d872-0cb7-44a4-8b2a-1680dd82e11e", "name": "", "x": 38.594091817303486, "y": -122.52510740253169, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ead37cb8-af1e-4a46-9466-6ff298b7f8b7", "name": "p1rlv18201", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c5d6d872-0cb7-44a4-8b2a-1680dd82e11e"}}}}, {"uuid": "d543b5e5-21eb-4d18-83f8-f17b77f46c83", "name": "", "x": 38.59405153241799, "y": -122.52501401155037, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cfb41891-7063-44b8-9286-1fe763e49924", "name": "p1rdt8493", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d543b5e5-21eb-4d18-83f8-f17b77f46c83"}}}}, {"uuid": "e2336c83-39fe-4b64-9b84-2eb2f4408be8", "name": "", "x": 38.6026030514407, "y": -122.53507494861152, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "409a29cf-ddd5-4031-92ca-db6cd2410704", "name": "p1rdt6028_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e2336c83-39fe-4b64-9b84-2eb2f4408be8"}}}}, {"uuid": "84a1a7b9-2f6d-432e-8a26-762b186fd77d", "name": "", "x": 38.67296456591668, "y": -122.57311952323086, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0921e58d-1ada-4556-8b01-8f22d3bf4ee2", "name": "p1rdt93lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "84a1a7b9-2f6d-432e-8a26-762b186fd77d"}}}}, {"uuid": "19391878-f7ac-418c-985a-d1d03bec6f38", "name": "", "x": 38.67288108818913, "y": -122.57387827884625, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3df778b4-e60b-4e17-b24b-67742d090f42", "name": "p1rlv183", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "19391878-f7ac-418c-985a-d1d03bec6f38"}}}}, {"uuid": "08de448b-f269-408e-8555-53810fe0aea3", "name": "", "x": 38.67284336560701, "y": -122.57341867755696, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d663fcdc-6c67-4bc9-99ed-12439f75804f", "name": "p1rlv204", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "08de448b-f269-408e-8555-53810fe0aea3"}}}}, {"uuid": "afc1a4c5-298c-454e-94d8-c72167c86521", "name": "", "x": 38.672896260917035, "y": -122.57309648596055, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2be21180-bfa8-4cd1-a3c5-68602896d657", "name": "p1rdm198", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "afc1a4c5-298c-454e-94d8-c72167c86521"}}}}, {"uuid": "f2445300-d709-40be-9352-addfc8d3546e", "name": "", "x": 38.67255503590974, "y": -122.57343188427429, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "90aa0d14-285a-4468-bbde-8d76f65b1780", "name": "p1rlv206", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f2445300-d709-40be-9352-addfc8d3546e"}}}}, {"uuid": "38a53f09-a685-40f7-b20c-a7170caea4fb", "name": "", "x": 38.67306781717814, "y": -122.57318743231879, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6a70fd02-3816-451f-a509-2ad767068eb4", "name": "p1rdm199", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "38a53f09-a685-40f7-b20c-a7170caea4fb"}}}}, {"uuid": "0c9426a0-9096-48e9-90ab-ad9746ad6f6f", "name": "", "x": 38.67309761817342, "y": -122.5739459691624, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6627102c-4524-4e69-bb4d-5b93226df412", "name": "p1rlv207", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0c9426a0-9096-48e9-90ab-ad9746ad6f6f"}}}}, {"uuid": "6210c740-6072-4fd5-8cb2-494c338084d5", "name": "", "x": 38.673202949412286, "y": -122.57317513422406, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6065e92f-dd89-4aeb-94af-173d81a49df1", "name": "p1rdm196", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6210c740-6072-4fd5-8cb2-494c338084d5"}}}}, {"uuid": "383df165-d455-44d1-aaa7-d9d026fa4bf3", "name": "", "x": 38.67319695527533, "y": -122.57400285874593, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "42ca8327-5dcc-415a-820c-ef6ec038b3d8", "name": "p1rlv184", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "383df165-d455-44d1-aaa7-d9d026fa4bf3"}}}}, {"uuid": "0fb5e2e8-91ff-4337-ae5c-5874c4a5a5b4", "name": "", "x": 38.6716242440999, "y": -122.57350240564409, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ef6be92d-5d1b-40e2-a2c2-9d0c1f0bf596", "name": "p1rdt99lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0fb5e2e8-91ff-4337-ae5c-5874c4a5a5b4"}}}}, {"uuid": "121accee-3c5d-4d8e-afbd-aa488401ee1b", "name": "", "x": 38.67172785280663, "y": -122.57395408806927, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33b6400e-c84e-43cf-b254-99f946e5a308", "name": "p1rlv190", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "121accee-3c5d-4d8e-afbd-aa488401ee1b"}}}}, {"uuid": "9ab562c3-fcf0-48cb-91a8-6a775a66e30e", "name": "", "x": 38.671562374281784, "y": -122.57305842624851, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "de2366e4-30da-429a-82b9-c0ef27eeab47", "name": "p1rlv202", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9ab562c3-fcf0-48cb-91a8-6a775a66e30e"}}}}, {"uuid": "371eadd3-a103-436e-b114-f0c24aaa1d57", "name": "", "x": 38.674085731551074, "y": -122.57304573384614, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1277a701-9fbd-4853-a809-962475e016c4", "name": "p1rdt101lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "371eadd3-a103-436e-b114-f0c24aaa1d57"}}}}, {"uuid": "11a58949-2b98-49be-b558-d21e2a7bea41", "name": "", "x": 38.674164000252716, "y": -122.57229574382116, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "84223c1b-69e4-4ebc-8274-8706bb412780", "name": "p1rlv193", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "11a58949-2b98-49be-b558-d21e2a7bea41"}}}}, {"uuid": "3042c514-d9a7-4cbf-b292-08e4f7e3bf5f", "name": "", "x": 38.673326264900375, "y": -122.57317042703883, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3aa8d6f2-8d84-42d6-8e7b-89e3b1efa03c", "name": "p1rdt108lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3042c514-d9a7-4cbf-b292-08e4f7e3bf5f"}}}}, {"uuid": "fba9d52a-56da-4743-9f43-d8e41e614e35", "name": "", "x": 38.673338794652196, "y": -122.57335825878279, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a982feac-5730-4fe0-a1b8-25c06b36e3b0", "name": "p1rlv212", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fba9d52a-56da-4743-9f43-d8e41e614e35"}}}}, {"uuid": "6f53652c-c937-430f-839f-ab69e81b2b63", "name": "", "x": 38.661367233687706, "y": -122.56984548041399, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "448cc5e0-391f-4a6b-8199-25cef4593edf", "name": "p1rdt6121lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6f53652c-c937-430f-839f-ab69e81b2b63"}}}}, {"uuid": "489d0901-4beb-4fa1-98a8-56a8df5765df", "name": "", "x": 38.66161605427373, "y": -122.56888775894382, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "163c3824-6847-4b94-9e81-08f15f4667a1", "name": "p1rlv12687", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "489d0901-4beb-4fa1-98a8-56a8df5765df"}}}}, {"uuid": "18b06d68-ca94-4d75-b53f-e26986e76248", "name": "", "x": 38.66221308963423, "y": -122.56844471302269, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e81ba94-5857-42e4-aeee-58542cef0fb6", "name": "p1rdt6123lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "18b06d68-ca94-4d75-b53f-e26986e76248"}}}}, {"uuid": "5ab40600-e462-49b4-a6e1-97fcebd2e9c8", "name": "", "x": 38.662187146256294, "y": -122.5684020420726, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ff16aad0-98c1-4563-a844-e0ce909c1a79", "name": "p1rlv12713", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ab40600-e462-49b4-a6e1-97fcebd2e9c8"}}}}, {"uuid": "48892e13-368b-44ee-824c-fa7c114949e5", "name": "", "x": 38.666474403379304, "y": -122.59876007752939, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8428de0e-4b06-4f19-bffb-5fed32f96f67", "name": "p1rdt8017lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "48892e13-368b-44ee-824c-fa7c114949e5"}}}}, {"uuid": "4417ff6d-d2ea-4fe9-88cb-de12f1a6ab25", "name": "", "x": 38.666431086206416, "y": -122.59829258598047, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b53edd15-5a3e-4b7a-97c4-046582bb4801", "name": "p1rlv17006", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4417ff6d-d2ea-4fe9-88cb-de12f1a6ab25"}}}}, {"uuid": "308b380d-d41b-45f3-96de-9e617604886e", "name": "", "x": 38.66353413238862, "y": -122.60568928818653, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a367e687-b29a-44b4-a943-7b94762e549e", "name": "p1rdt8043lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "308b380d-d41b-45f3-96de-9e617604886e"}}}}, {"uuid": "08f15de6-260e-419d-911e-b628e755ff37", "name": "", "x": 38.6635082025271, "y": -122.60564660289965, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8ff9eb4c-2523-48e0-8490-619d26b9cca4", "name": "p1rlv17103", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "08f15de6-260e-419d-911e-b628e755ff37"}}}}, {"uuid": "3f5eea31-80ca-4830-9a4c-66869b9db1a5", "name": "", "x": 38.656285239065134, "y": -122.61480721656375, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8bb025c5-31eb-4771-b433-e1dcad03b3ed", "name": "p1rdt8065lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3f5eea31-80ca-4830-9a4c-66869b9db1a5"}}}}, {"uuid": "c7d84cbf-8e4a-40fa-948c-a37206aa3f12", "name": "", "x": 38.65636014038154, "y": -122.61479929639421, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3c6c52e-cf93-467a-a303-94b96b33a3da", "name": "p1rlv17155", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c7d84cbf-8e4a-40fa-948c-a37206aa3f12"}}}}, {"uuid": "57105b01-9e4d-457c-a82e-90b19eb89a1a", "name": "", "x": 38.65653706419615, "y": -122.61653379624518, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "62e77e46-bf33-474f-907b-81d36aae8975", "name": "p1rdm17752", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "57105b01-9e4d-457c-a82e-90b19eb89a1a"}}}}, {"uuid": "59295e4b-87ad-415c-8961-0244dffcbade", "name": "", "x": 38.656142018437656, "y": -122.61698412819987, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "041caa30-2985-44ca-8013-e11a9bda7dff", "name": "p1rlv17164", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59295e4b-87ad-415c-8961-0244dffcbade"}}}}, {"uuid": "73d19644-a33b-400d-bc6c-0b09086220d9", "name": "", "x": 38.65646182364152, "y": -122.61643827928047, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dd01eed6-0e70-42e7-ac29-4bfd2f70366a", "name": "p1rdt8068lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "73d19644-a33b-400d-bc6c-0b09086220d9"}}}}, {"uuid": "e8387e72-4704-4ccd-ba30-31f1bae60656", "name": "", "x": 38.6564643300682, "y": -122.61633880273914, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "46b5c5bc-6738-4520-b98c-32bd43f4c91c", "name": "p1rdm17753", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e8387e72-4704-4ccd-ba30-31f1bae60656"}}}}, {"uuid": "04a61433-ab27-4c19-8d09-b9a8f24e0620", "name": "", "x": 38.65583419030237, "y": -122.6165490366375, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5768eaca-abe3-4347-af78-02b50ec6f2a9", "name": "p1rlv17199", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "04a61433-ab27-4c19-8d09-b9a8f24e0620"}}}}, {"uuid": "e26f0031-1622-4dc5-844f-d31e2652eff3", "name": "", "x": 38.656487161757404, "y": -122.6159209581833, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d0bcd460-ccf2-42ee-83c6-bada397ab4d6", "name": "p1rdt8070lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e26f0031-1622-4dc5-844f-d31e2652eff3"}}}}, {"uuid": "ddb8eca2-3f6e-48b5-9bd6-8b8c916885cf", "name": "", "x": 38.65609360641926, "y": -122.61596151268897, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2b4e44ab-e644-4e48-b1b2-82dc15d38d17", "name": "p1rlv17167", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ddb8eca2-3f6e-48b5-9bd6-8b8c916885cf"}}}}, {"uuid": "5d80fb83-4c57-405b-be79-fefbfe9f0f29", "name": "", "x": 38.66692113690325, "y": -122.58783715855819, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f21f4e99-8877-4bb0-9956-9240bc6db3d1", "name": "p1rdt8190lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5d80fb83-4c57-405b-be79-fefbfe9f0f29"}}}}, {"uuid": "0ec4963f-c030-40aa-8f4c-bf6e68b00d71", "name": "", "x": 38.66724289358908, "y": -122.58733754347764, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8c9970ae-e914-407d-8222-12c08638a854", "name": "p1rlv17376", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0ec4963f-c030-40aa-8f4c-bf6e68b00d71"}}}}, {"uuid": "d61466da-7b42-4518-90f7-f4815488ce05", "name": "", "x": 38.664369444812806, "y": -122.58690973341812, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d12bf6fb-8dac-4729-bcda-1ee61c63f6e8", "name": "p1rdt8204lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d61466da-7b42-4518-90f7-f4815488ce05"}}}}, {"uuid": "0a451f8e-953d-4a4d-8347-edad82693b2c", "name": "", "x": 38.66416826088575, "y": -122.58688392637725, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dc7fa312-1baf-4f23-925f-a281071183a6", "name": "p1rlv17402", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a451f8e-953d-4a4d-8347-edad82693b2c"}}}}, {"uuid": "4b26802d-e23c-4468-b2c3-580cea831428", "name": "", "x": 38.6664926486277, "y": -122.58749879976138, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ecf11723-eb6d-423c-ac0c-85fa2d1ba846", "name": "p1rdt8208lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4b26802d-e23c-4468-b2c3-580cea831428"}}}}, {"uuid": "4ac2c5c1-618e-4106-b26e-5c3773bf4c79", "name": "", "x": 38.666718636185976, "y": -122.58689226135496, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f147f7e5-33e8-430b-9822-715e772debb3", "name": "p1rlv17413", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ac2c5c1-618e-4106-b26e-5c3773bf4c79"}}}}, {"uuid": "f901d18c-7e76-4de4-83f3-504b150840d2", "name": "", "x": 38.6508349878355, "y": -122.52772270990391, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f1a593e3-4735-47d2-b893-dd2d07c3c47c", "name": "p1rdt8578lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f901d18c-7e76-4de4-83f3-504b150840d2"}}}}, {"uuid": "fa2bab8c-4741-4c89-a36e-0f401dc5f8f6", "name": "", "x": 38.6509409741122, "y": -122.52789042198899, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5a28b095-45f5-43ec-983b-c1de596d4cb5", "name": "p1rlv18362", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa2bab8c-4741-4c89-a36e-0f401dc5f8f6"}}}}, {"uuid": "54e5f769-3d1c-4b01-8a58-c3530ce25014", "name": "", "x": 38.65066839894964, "y": -122.52734059189255, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8d1c3d0a-9def-4516-8429-386f1d70f506", "name": "p1rlv18364", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "54e5f769-3d1c-4b01-8a58-c3530ce25014"}}}}, {"uuid": "3d133081-f320-481d-93db-a3b5dcc28d51", "name": "", "x": 38.650824008938194, "y": -122.52793715797524, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "408c825d-17ac-4aea-9fc7-fff420657fc7", "name": "p1rlv18367", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3d133081-f320-481d-93db-a3b5dcc28d51"}}}}, {"uuid": "fa1ac5d2-b7cb-453b-9242-5ea28ea7b3ab", "name": "", "x": 38.647860789632105, "y": -122.5254589040337, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "134bac3d-5b7e-48d7-950e-01e5b7d43852", "name": "p1rdt8583lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa1ac5d2-b7cb-453b-9242-5ea28ea7b3ab"}}}}, {"uuid": "d536c44b-825c-4165-812f-b5fa407dad21", "name": "", "x": 38.64817724906055, "y": -122.52638016767358, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "905e171c-13d7-4f8d-b88a-7501b2327d81", "name": "p1rlv18370", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d536c44b-825c-4165-812f-b5fa407dad21"}}}}, {"uuid": "a6f0e76a-a551-45f5-a544-955ccc0eb60d", "name": "", "x": 38.64706546256806, "y": -122.5262571069094, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a8ba1042-fcfd-47a8-aa0f-8b13618d3212", "name": "p1rdt8584lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a6f0e76a-a551-45f5-a544-955ccc0eb60d"}}}}, {"uuid": "7891f0b1-efd2-44fb-9612-2be3e5dd1ef6", "name": "", "x": 38.64750833323082, "y": -122.52657595427343, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "58792e8c-3ad9-45bb-ac47-01983cca2a2b", "name": "p1rlv18371", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7891f0b1-efd2-44fb-9612-2be3e5dd1ef6"}}}}, {"uuid": "ee4e0a8b-2d46-4187-a857-a2e71a918ff8", "name": "", "x": 38.66789379909343, "y": -122.62737431712556, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c8f14e6e-ee96-4ae9-86ba-4a07cf103b65", "name": "p1rdt10491lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ee4e0a8b-2d46-4187-a857-a2e71a918ff8"}}}}, {"uuid": "2655db2b-f896-45ca-817d-dba842af8f70", "name": "", "x": 38.66785523664377, "y": -122.62747399595972, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a86348e4-7573-4903-b223-90155579923e", "name": "p1rlv22745", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2655db2b-f896-45ca-817d-dba842af8f70"}}}}, {"uuid": "3acca42a-228d-405c-b242-24b9b408046c", "name": "", "x": 38.66771072023337, "y": -122.6273712914315, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ee8b6bab-9edd-4250-b57b-3a76b432fb54", "name": "p1rdm23269", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3acca42a-228d-405c-b242-24b9b408046c"}}}}, {"uuid": "e82104cd-1fd3-4a40-84ae-355f99fe8c59", "name": "", "x": 38.66773801158078, "y": -122.62745161373962, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "db05b7f0-d2a8-4876-876e-ef0e9b469580", "name": "p1rlv22758", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e82104cd-1fd3-4a40-84ae-355f99fe8c59"}}}}, {"uuid": "5b6968d5-f9b5-4ee7-adba-3b83bc1f93d0", "name": "", "x": 38.656528899791525, "y": -122.61592868327206, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "473520c7-0098-4bc2-a46f-07efd6c3759c", "name": "p1rdt8070", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5b6968d5-f9b5-4ee7-adba-3b83bc1f93d0"}}}}, {"uuid": "7bb0f297-562b-497d-b9ce-36499e5b1011", "name": "", "x": 38.6563269771708, "y": -122.61481494098487, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "862f3566-9443-4b82-8f05-c994581e131a", "name": "p1rdt8065", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7bb0f297-562b-497d-b9ce-36499e5b1011"}}}}, {"uuid": "5b97a273-c1db-4cad-ba97-ea0ec4645596", "name": "", "x": 38.65650356164319, "y": -122.61644600466717, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7f5fbb8b-0c32-4aa7-acaf-7ea2b5e56505", "name": "p1rdt8068", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5b97a273-c1db-4cad-ba97-ea0ec4645596"}}}}, {"uuid": "3e57a0ea-ffba-40e1-804e-eaa3a7897315", "name": "", "x": 38.663548423315845, "y": -122.60574012937602, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "691c1909-3b71-4e07-abf0-95aaabfa23bb", "name": "p1rdt8043", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e57a0ea-ffba-40e1-804e-eaa3a7897315"}}}}, {"uuid": "ed6aebf5-9450-4578-881d-cae98151a49d", "name": "", "x": 38.65907117917629, "y": -122.61161258790305, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cbafbe81-1649-4bae-b9af-c4b1757392f0", "name": "p1rdt8043-p1rdt8070x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ed6aebf5-9450-4578-881d-cae98151a49d"}}}}, {"uuid": "6c8fea95-a7aa-4e43-ab48-30f65042e891", "name": "", "x": 38.66743589391774, "y": -122.62597035336422, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ca19324f-0855-4633-be68-b16c872e196d", "name": "p1rdt10491-p1rdt8043x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c8fea95-a7aa-4e43-ab48-30f65042e891"}}}}, {"uuid": "99689df4-980e-4bb2-b002-ae9a37ffd539", "name": "", "x": 38.667852061856834, "y": -122.62736658421983, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4737e613-8cf5-45d7-a3f5-71af051ece4c", "name": "p1rdt10491", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "99689df4-980e-4bb2-b002-ae9a37ffd539"}}}}, {"uuid": "6499ec0f-5e4c-4c55-9d87-b9feec61c306", "name": "", "x": 38.666432664329825, "y": -122.59875236139737, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6378abd-969e-4ec8-93eb-2cc39cdb18eb", "name": "p1rdt8017", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6499ec0f-5e4c-4c55-9d87-b9feec61c306"}}}}, {"uuid": "f8c35a56-8487-4552-91de-996ae7e93a21", "name": "", "x": 38.665466700320124, "y": -122.60006059980222, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "feda8d99-6fae-4c6e-bf52-f87894687da5", "name": "p1rdt8017-p1rdt8043x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f8c35a56-8487-4552-91de-996ae7e93a21"}}}}, {"uuid": "b47e2761-7265-4eda-9f5e-916e5198314b", "name": "", "x": 38.67412513347839, "y": -122.57295162842586, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a09cdbca-4e7b-4d9a-b479-515074964171", "name": "p1rdt101-p1rdt8017x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b47e2761-7265-4eda-9f5e-916e5198314b"}}}}, {"uuid": "0d8f64aa-a831-414b-b33d-90920ccc73f2", "name": "", "x": 38.67372843812363, "y": -122.57642531522278, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b1aeba4b-536e-4067-a7a5-627470ae0711", "name": "p1rdt101-p1rdt8017xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0d8f64aa-a831-414b-b33d-90920ccc73f2"}}}}, {"uuid": "cb64d0c5-316b-4ef4-9fc4-06dc369727d9", "name": "", "x": 38.6667923442126, "y": -122.59769681955328, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8c1a4365-a594-48be-b138-aa6935c34481", "name": "p1rdt101-p1rdt8017xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb64d0c5-316b-4ef4-9fc4-06dc369727d9"}}}}, {"uuid": "6b0aaced-0cdb-4e3b-9ab8-ec56496f99ba", "name": "", "x": 38.67336800550842, "y": -122.57317812900477, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e61ce952-a643-45aa-a466-8aa15ecceb48", "name": "p1rdt108", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6b0aaced-0cdb-4e3b-9ab8-ec56496f99ba"}}}}, {"uuid": "cc9a67b6-79b9-4193-be24-d3b00a83c29d", "name": "", "x": 38.67409957836356, "y": -122.57299468560076, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2d8e5d83-cd9c-4527-9eef-6219c98dfe93", "name": "p1rdt101", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc9a67b6-79b9-4193-be24-d3b00a83c29d"}}}}, {"uuid": "cbcc0bc7-f2c6-4318-8fe8-f233849842d7", "name": "", "x": 38.673004812616185, "y": -122.57321304352497, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a4f100ee-0152-4e27-bf0e-2c7dea1537ad", "name": "p1rdt108-p1rdt93x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cbcc0bc7-f2c6-4318-8fe8-f233849842d7"}}}}, {"uuid": "80f718dd-80a7-4d45-98b2-65163070d903", "name": "", "x": 38.66653438838322, "y": -122.58750650935949, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8e2b4d77-2388-4897-86fe-06409fa9d222", "name": "p1rdt8208", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "80f718dd-80a7-4d45-98b2-65163070d903"}}}}, {"uuid": "c15f08e7-d9f7-403e-a6d8-3b883874c9fc", "name": "", "x": 38.6643277050057, "y": -122.58690202438763, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fa2342e6-2d40-424a-830c-a84af4632b6e", "name": "p1rdt8204", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c15f08e7-d9f7-403e-a6d8-3b883874c9fc"}}}}, {"uuid": "914c9442-7ee2-4f65-83b0-5589227565a3", "name": "", "x": 38.66696287663581, "y": -122.58784486869551, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0a761aef-a766-40e2-b8d7-e5a918cece18", "name": "p1rdt8190", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "914c9442-7ee2-4f65-83b0-5589227565a3"}}}}, {"uuid": "2b710d2f-ba85-48eb-b045-0a1e53513481", "name": "", "x": 38.66701682299843, "y": -122.58779500809689, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b860d5c-43e4-429e-b945-378020e3f926", "name": "p1rdt8190-p1rdt99xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2b710d2f-ba85-48eb-b045-0a1e53513481"}}}}, {"uuid": "45f324c1-53a0-4c45-84bb-8247a59540a3", "name": "", "x": 38.67081351738392, "y": -122.57529296188245, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6be75535-8c32-47ea-bad5-986daaed0921", "name": "p1rdt8190-p1rdt99x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "45f324c1-53a0-4c45-84bb-8247a59540a3"}}}}, {"uuid": "bd0ae6f7-68ed-42de-91dc-6e78b005e83b", "name": "", "x": 38.661326984313604, "y": -122.56975197710662, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ddf8f344-dcca-418d-850e-745f18d29660", "name": "p1rdt6121-p1rdt6123x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bd0ae6f7-68ed-42de-91dc-6e78b005e83b"}}}}, {"uuid": "1062a7cd-f594-4e16-9327-1fee2a297714", "name": "", "x": 38.6622273967057, "y": -122.56849554572818, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "17f807ba-6ad6-4fd9-9dd0-2c0bacea5b24", "name": "p1rdt6123", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1062a7cd-f594-4e16-9327-1fee2a297714"}}}}, {"uuid": "b1a6adaf-4169-404d-815c-821d17c42c72", "name": "", "x": 38.64782050495066, "y": -122.52536544340624, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d0747505-3381-4df0-a86e-3859acac8496", "name": "p1rdt8583-p1rdt8584x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b1a6adaf-4169-404d-815c-821d17c42c72"}}}}, {"uuid": "6fe736f3-597d-4832-a078-7f9462c6089a", "name": "", "x": 38.64710720626507, "y": -122.52626477895555, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2b601580-3091-4d8c-9718-1367c7ed385f", "name": "p1rdt8584", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6fe736f3-597d-4832-a078-7f9462c6089a"}}}}, {"uuid": "b74c66f5-7370-4363-aadb-c2963556dbbb", "name": "", "x": 38.67166598469829, "y": -122.57351010762986, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "092a9d51-a39c-4c05-905e-93fb1ae96ba2", "name": "p1rdt99", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b74c66f5-7370-4363-aadb-c2963556dbbb"}}}}, {"uuid": "c251ee2b-6d25-444e-84ed-7a550939f36b", "name": "", "x": 38.671869985546934, "y": -122.57338996774229, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e3d15ce6-878d-4dd5-bb33-5a0f6c11dded", "name": "p1rdt93-p1rdt99x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c251ee2b-6d25-444e-84ed-7a550939f36b"}}}}, {"uuid": "3c977c81-252d-4ac1-99d0-aac8f9743cbc", "name": "", "x": 38.67299050757224, "y": -122.5731622022605, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "900d49ce-4834-4f99-8d74-a5e9d2f63ea0", "name": "p1rdt93", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3c977c81-252d-4ac1-99d0-aac8f9743cbc"}}}}, {"uuid": "2bd1ce4a-a2d6-48af-9731-0ffbbac3c303", "name": "", "x": 38.66135292720275, "y": -122.56979464804087, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2390c014-d418-4d63-8438-529a036487db", "name": "p1rdt6121", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2bd1ce4a-a2d6-48af-9731-0ffbbac3c303"}}}}, {"uuid": "c7db02d4-5bc2-4f36-97d1-dfc8a8bdabb6", "name": "", "x": 38.66910358694126, "y": -122.57345236501213, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "49c9e6df-3490-4df1-88a0-8a83ca6cdd1e", "name": "p1rdt6121-p1rdt99x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c7db02d4-5bc2-4f36-97d1-dfc8a8bdabb6"}}}}, {"uuid": "697424df-cd5f-4975-84bb-60f564edf569", "name": "", "x": 38.650793244252796, "y": -122.52771503663553, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bb866499-9e9c-4394-bd76-d4320ba4934b", "name": "p1rdt8578", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "697424df-cd5f-4975-84bb-60f564edf569"}}}}, {"uuid": "35989896-71ba-4201-91dc-e454d727ee91", "name": "", "x": 38.660311758411375, "y": -122.56710257404733, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "af229e5c-a70f-4354-bddc-4a2698802741", "name": "p1rdt6121-p1rdt8578x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "35989896-71ba-4201-91dc-e454d727ee91"}}}}, {"uuid": "939671ba-5e71-4c33-a5b6-6ae2212229dc", "name": "", "x": 38.64784646411654, "y": -122.52540809020192, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dbb79e10-21ba-4f04-b8a3-0cf711d26d40", "name": "p1rdt8583", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "939671ba-5e71-4c33-a5b6-6ae2212229dc"}}}}, {"uuid": "1d950e8d-70ee-4f99-a69a-f6c10714f0b3", "name": "", "x": 38.648598745729544, "y": -122.52587175663075, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "975237e9-bd83-4a30-83ab-221eb7f85c65", "name": "p1rdt8578-p1rdt8583x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d950e8d-70ee-4f99-a69a-f6c10714f0b3"}}}}, {"uuid": "614fdcef-422b-4210-b725-39f50e5db0bf", "name": "635840a4-7200-4618-8afc-99b9529d4031_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_voltagesource_equipment", "type": "PhaseVoltageSourceEquipment", "serialized_type": "base"}}, "r0": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Resistance", "serialized_type": "quantity"}}}, "r1": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Resistance", "serialized_type": "quantity"}}}, "x0": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Reactance", "serialized_type": "quantity"}}}, "x1": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Reactance", "serialized_type": "quantity"}}}, "voltage": {"value": 39.838337182448036, "units": "kilovolt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "angle": {"value": 0.0, "units": "degree", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Angle", "serialized_type": "quantity"}}}}, {"uuid": "14c8c055-5866-4494-860e-192d157bb809", "name": "635840a4-7200-4618-8afc-99b9529d4031_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_voltagesource_equipment", "type": "PhaseVoltageSourceEquipment", "serialized_type": "base"}}, "r0": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Resistance", "serialized_type": "quantity"}}}, "r1": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Resistance", "serialized_type": "quantity"}}}, "x0": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Reactance", "serialized_type": "quantity"}}}, "x1": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Reactance", "serialized_type": "quantity"}}}, "voltage": {"value": 39.838337182448036, "units": "kilovolt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "angle": {"value": 120.0, "units": "degree", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Angle", "serialized_type": "quantity"}}}}, {"uuid": "00dfcdee-b9ee-489c-a339-b4615d17c496", "name": "635840a4-7200-4618-8afc-99b9529d4031_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_voltagesource_equipment", "type": "PhaseVoltageSourceEquipment", "serialized_type": "base"}}, "r0": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Resistance", "serialized_type": "quantity"}}}, "r1": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Resistance", "serialized_type": "quantity"}}}, "x0": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Reactance", "serialized_type": "quantity"}}}, "x1": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Reactance", "serialized_type": "quantity"}}}, "voltage": {"value": 39.838337182448036, "units": "kilovolt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "angle": {"value": 240.0, "units": "degree", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Angle", "serialized_type": "quantity"}}}}, {"uuid": "ff5789ac-35ae-461f-8d88-cd7b58b34ab3", "name": "635840a4-7200-4618-8afc-99b9529d4031", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.voltagesource_equipment", "type": "VoltageSourceEquipment", "serialized_type": "base"}}, "sources": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_voltagesource_equipment", "type": "PhaseVoltageSourceEquipment", "serialized_type": "composed_component", "uuid": "614fdcef-422b-4210-b725-39f50e5db0bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_voltagesource_equipment", "type": "PhaseVoltageSourceEquipment", "serialized_type": "composed_component", "uuid": "14c8c055-5866-4494-860e-192d157bb809"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_voltagesource_equipment", "type": "PhaseVoltageSourceEquipment", "serialized_type": "composed_component", "uuid": "00dfcdee-b9ee-489c-a339-b4615d17c496"}}}]}, {"uuid": "267037ac-94da-4162-9484-f2f5d9cab688", "name": "source", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_vsource", "type": "DistributionVoltageSource", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "574ab810-c1b0-4662-8c4d-f32ab6893a36"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.voltagesource_equipment", "type": "VoltageSourceEquipment", "serialized_type": "composed_component", "uuid": "ff5789ac-35ae-461f-8d88-cd7b58b34ab3"}}}}, {"uuid": "e5469e34-b4db-4115-9139-ffc60bb49bbd", "name": "546d6ea1-cd18-4228-8edd-9598526a92df_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.840334051658807, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.3948056193408553, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "67309e73-810a-4c78-8158-ce7710efe7e3", "name": "0de45f54-cece-4e94-844c-81772bee923e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e5469e34-b4db-4115-9139-ffc60bb49bbd"}}}]}, {"uuid": "d8d6bc4a-d96f-43ae-bc69-823255ae76bd", "name": "load_p1rlv10170_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02e86824-b793-4080-9401-c6995a365baf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "67309e73-810a-4c78-8158-ce7710efe7e3"}}}}, {"uuid": "20c0e7c7-8721-449c-8c78-09d4f3da035a", "name": "8ee826d6-19c9-4320-b5fa-c5423073ad16_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.840334051658807, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.3948056193408553, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4b2bfcd5-d8c2-4fcf-a9ef-c821a2fc7a47", "name": "7cd431cb-01ba-4354-b594-83a35144906b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "20c0e7c7-8721-449c-8c78-09d4f3da035a"}}}]}, {"uuid": "4299a3aa-ba1d-4f0a-832e-e4ee9347ae96", "name": "load_p1rlv10170_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02e86824-b793-4080-9401-c6995a365baf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4b2bfcd5-d8c2-4fcf-a9ef-c821a2fc7a47"}}}}, {"uuid": "129db834-e664-434f-8575-b55557c4d16d", "name": "3159695e-34c3-44b2-99ac-8f94ad58ec5f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5675771284059596, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.814222257775612, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1fa7a333-c682-4f9f-b838-214a1d8e9d1c", "name": "1c0a9cd1-4dfa-42e3-9507-6749ffbb8be3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "129db834-e664-434f-8575-b55557c4d16d"}}}]}, {"uuid": "b92a9605-b0ce-432e-98e8-89764b805b42", "name": "load_p1rlv10189_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58f2b2c3-4f6f-4fd2-abb9-42ff665692bd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1fa7a333-c682-4f9f-b838-214a1d8e9d1c"}}}}, {"uuid": "3b57b23f-b611-422d-8dfb-191cdc583f6f", "name": "0d6e89aa-c113-496d-b3b7-27aaa1bc6294_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5675771284059596, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.814222257775612, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5ed83898-2733-4cea-a50f-5d2f64738b3f", "name": "45b095f5-c1e1-4fd2-9c6f-b5c6cbd9d6fe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3b57b23f-b611-422d-8dfb-191cdc583f6f"}}}]}, {"uuid": "18684a60-bdcf-4ecb-b451-206191b5b387", "name": "load_p1rlv10189_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58f2b2c3-4f6f-4fd2-abb9-42ff665692bd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5ed83898-2733-4cea-a50f-5d2f64738b3f"}}}}, {"uuid": "b50974d8-7716-4e1f-a154-58141fe96159", "name": "07638998-4261-4040-9283-9a1ceeb6a17a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2859398622891502, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31064660144885853, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8262d88d-f6d6-4195-84e4-1ef29d502f23", "name": "c5ca30e9-1a76-466f-8aac-a8ac6cca0e2a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b50974d8-7716-4e1f-a154-58141fe96159"}}}]}, {"uuid": "f0b7de95-2441-47ba-b581-d2b2deff0a7c", "name": "load_p1rlv10262_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3317d7c2-2588-426d-91fc-3d765b932da6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8262d88d-f6d6-4195-84e4-1ef29d502f23"}}}}, {"uuid": "8a589d2d-8bb5-4a2d-a783-bae8c6be7f51", "name": "53619472-8b4a-4e99-8f1e-373fe1c283b8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2859398622891502, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31064660144885853, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d1078032-48da-45a9-9514-1bd009f80425", "name": "cae9ace2-76c6-4edb-a648-864e751d71b3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a589d2d-8bb5-4a2d-a783-bae8c6be7f51"}}}]}, {"uuid": "bd031773-5a92-44a8-b655-5ce11b5a4e7b", "name": "load_p1rlv10262_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3317d7c2-2588-426d-91fc-3d765b932da6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d1078032-48da-45a9-9514-1bd009f80425"}}}}, {"uuid": "993432e9-66d3-4fc9-affe-9f6530caeac7", "name": "91274f2d-6b69-4a31-922c-34d0fd405697_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.598111299087247, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3022070914124596, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5c9059e0-2b4a-4ed3-8029-709216e1ff3f", "name": "ee60a67d-83a4-4707-a5ce-a17eb9457a3b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "993432e9-66d3-4fc9-affe-9f6530caeac7"}}}]}, {"uuid": "efed8560-d920-49e0-8ae6-7fa50af9ebef", "name": "load_p1rlv10491_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f7116b9-96c1-42c8-850f-7787f5fd0f96"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5c9059e0-2b4a-4ed3-8029-709216e1ff3f"}}}}, {"uuid": "804be5d0-f940-44d3-87a2-1666ca6bfd99", "name": "8472f830-52fe-4e78-8f35-3650a707dfc3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.598111299087247, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3022070914124596, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e15b851c-dbf3-403b-9ce4-125e3739f110", "name": "5ae5f7ac-f7e3-44c4-81ed-2fd9c6cc7ceb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "804be5d0-f940-44d3-87a2-1666ca6bfd99"}}}]}, {"uuid": "c9f4b35b-fff0-42fe-9c01-70fec1a715f5", "name": "load_p1rlv10491_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f7116b9-96c1-42c8-850f-7787f5fd0f96"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e15b851c-dbf3-403b-9ce4-125e3739f110"}}}}, {"uuid": "2335485c-19cd-4605-9529-64275bc82eb0", "name": "a7ad5af2-a876-40d2-be51-500cc561015e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.388743979084916, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.03502268140121, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "867db88d-63b7-4bee-905f-784adcb5e721", "name": "3ef95a16-ca14-44b8-8a43-40eb5ab8cc7c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2335485c-19cd-4605-9529-64275bc82eb0"}}}]}, {"uuid": "0dc080b9-936f-4c3a-8e91-4be50f2719d3", "name": "load_p1rlv10521_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31f26b28-fc9d-4b3d-b204-cf40f3478c44"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "867db88d-63b7-4bee-905f-784adcb5e721"}}}}, {"uuid": "8418f1e2-1166-44ca-93f2-2f746cabc291", "name": "d8b85703-88cb-4147-9b12-71cc788bb321_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.388743979084916, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.03502268140121, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aa1ebe23-a640-41b4-bf0e-695a31d0e2b9", "name": "b4b52ff8-feab-429c-bfa7-67cfc1e912a9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8418f1e2-1166-44ca-93f2-2f746cabc291"}}}]}, {"uuid": "88b9c328-7f31-4d26-a036-a54f56ce234b", "name": "load_p1rlv10521_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31f26b28-fc9d-4b3d-b204-cf40f3478c44"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aa1ebe23-a640-41b4-bf0e-695a31d0e2b9"}}}}, {"uuid": "8c834a48-84b5-4861-bb74-d75985b72713", "name": "5d0dc6e4-fbab-47f9-8a91-231f6c1cdacb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0052757727111112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4127143879372469, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "88c22e57-29b7-47d0-b622-ffe83d964647", "name": "0ccc4eb5-9755-4d5f-a364-0f965120d933", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8c834a48-84b5-4861-bb74-d75985b72713"}}}]}, {"uuid": "9af6766f-1fd9-4825-a24d-8626cd72f11f", "name": "load_p1rlv10523_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35d47036-a044-4c67-b5b5-0006e2a3b68e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "88c22e57-29b7-47d0-b622-ffe83d964647"}}}}, {"uuid": "8e2f3d41-662e-4980-a1b7-c7fb900caf45", "name": "6647fe10-6588-4164-9eb3-fea25d2a9462_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0052757727111112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4127143879372469, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b8189c3a-08fd-4911-a1b5-f0955e23a3a3", "name": "cb7b10a1-ef90-490e-a741-057dbb9d5a98", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8e2f3d41-662e-4980-a1b7-c7fb900caf45"}}}]}, {"uuid": "5d074c7c-783a-49b5-bbf6-863562eb73a0", "name": "load_p1rlv10523_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35d47036-a044-4c67-b5b5-0006e2a3b68e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b8189c3a-08fd-4911-a1b5-f0955e23a3a3"}}}}, {"uuid": "61dccb8d-ca08-485b-a85d-1ddcd11916ad", "name": "88a2a0b3-fce5-4f48-bfa4-7b1781a741ff_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.346612792133217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8934968317135462, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0338a4f1-fc36-4a79-8794-79a666eb2c08", "name": "fa4c633e-4531-48d1-a321-07ff0c9e763c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "61dccb8d-ca08-485b-a85d-1ddcd11916ad"}}}]}, {"uuid": "92703db3-7c03-43fd-ad1e-f9cfeba4b985", "name": "load_p1rlv10538_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a302271d-4cf3-45ff-9308-b9cf31fbefa3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0338a4f1-fc36-4a79-8794-79a666eb2c08"}}}}, {"uuid": "98bcc0db-9132-4a3c-b610-06c2a350389a", "name": "325c85da-bcf2-4095-a07b-f0d830768108_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.346612792133217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8934968317135462, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ca6b885e-c8f9-4c05-959a-8d15c50227f0", "name": "d67af9d6-ac8e-411c-9161-2fdf6f6679fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "98bcc0db-9132-4a3c-b610-06c2a350389a"}}}]}, {"uuid": "b731739f-fa18-4fad-905c-87443cfce5d5", "name": "load_p1rlv10538_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a302271d-4cf3-45ff-9308-b9cf31fbefa3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ca6b885e-c8f9-4c05-959a-8d15c50227f0"}}}}, {"uuid": "6163aa2a-d4cd-4dfd-ad54-185653ab500b", "name": "561cc921-b931-499a-9b8b-b842a3b37e3b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.732212626630997, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.8695385943463294, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a968d13-c9e7-46a9-91eb-97e0d61a66b4", "name": "561cc921-b931-499a-9b8b-b842a3b37e3b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.732212626630997, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.8695385943463294, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "265d3447-d136-4cd0-89e8-91663f91a7fb", "name": "561cc921-b931-499a-9b8b-b842a3b37e3b_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.732212626630997, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.8695385943463294, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ce4815e4-79ce-4a08-8a1b-ea8a864d4c9b", "name": "1d264e18-a308-48d9-8e38-d4620f923977", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6163aa2a-d4cd-4dfd-ad54-185653ab500b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0a968d13-c9e7-46a9-91eb-97e0d61a66b4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "265d3447-d136-4cd0-89e8-91663f91a7fb"}}}]}, {"uuid": "5a1b9a31-aa33-4417-9163-777f1be8b93c", "name": "load_p1rlv10539", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08331744-08b7-455e-b2ca-284cae95fb06"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ce4815e4-79ce-4a08-8a1b-ea8a864d4c9b"}}}}, {"uuid": "4acb4341-939b-4101-99e7-6eabbbfe10dc", "name": "1b203d67-d092-48e6-9fdd-033bd70091ff_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3798783675992279, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6151141774255103, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "029b3287-e402-41d2-ba35-dc675176b103", "name": "16e47c63-28f8-404d-af33-fb21391635d6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4acb4341-939b-4101-99e7-6eabbbfe10dc"}}}]}, {"uuid": "02684642-c54a-4ad2-85bf-c0eac2537c9d", "name": "load_p1rlv10540_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4829cd2f-7e61-4386-89ce-89d77d5ef5cf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "029b3287-e402-41d2-ba35-dc675176b103"}}}}, {"uuid": "779f5336-f165-4153-927c-a3b56b0c95df", "name": "4c549c39-eef7-4182-949e-97c202c2c5cf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3798783675992279, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6151141774255103, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "36fa9d3b-a675-47fe-8787-cbff3d8847d9", "name": "936c33b0-831b-434b-b429-dc6b6e5a83fe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "779f5336-f165-4153-927c-a3b56b0c95df"}}}]}, {"uuid": "2be448aa-639b-445d-93b9-eff7ac15c311", "name": "load_p1rlv10540_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4829cd2f-7e61-4386-89ce-89d77d5ef5cf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "36fa9d3b-a675-47fe-8787-cbff3d8847d9"}}}}, {"uuid": "872c6067-a8d5-4cf8-9df4-5bffa0ff49f2", "name": "75df7eb9-d32f-44f3-bffe-0c74d23011a3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9115470716545817, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7511996531223851, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b4e1f0ad-c09e-4b3d-91a8-e3e50dcc5fa4", "name": "e09b0864-5e4c-4a3f-bdf7-c34e3e6c2884", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "872c6067-a8d5-4cf8-9df4-5bffa0ff49f2"}}}]}, {"uuid": "447fbe14-d0f5-428a-ae6e-897576c45644", "name": "load_p1rlv10544_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c722b89-fdaf-416f-863e-02b443375ba1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b4e1f0ad-c09e-4b3d-91a8-e3e50dcc5fa4"}}}}, {"uuid": "d8732fcd-8c59-44e7-a017-e1215105f5fa", "name": "72fe6248-d802-4be6-8a03-77d6d027095e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9115470716545817, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7511996531223851, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "443403d0-6584-4bf0-a96a-f0f8755d8610", "name": "8b01779b-6a18-45ef-9644-0f429d6aa12b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d8732fcd-8c59-44e7-a017-e1215105f5fa"}}}]}, {"uuid": "4c73c470-77cf-4169-81a9-d2e62d49ce9a", "name": "load_p1rlv10544_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c722b89-fdaf-416f-863e-02b443375ba1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "443403d0-6584-4bf0-a96a-f0f8755d8610"}}}}, {"uuid": "34640cc1-c224-4d24-b99f-215e00359092", "name": "fc449386-6b31-4ddc-b229-a11c4e93b3fc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6295328634326751, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9988748196040309, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e761bf5d-8dac-40fe-bcc1-784c02d7c9e0", "name": "0d32055b-85ed-43e6-84b0-ea0daf522bd5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "34640cc1-c224-4d24-b99f-215e00359092"}}}]}, {"uuid": "43ed04f3-eff1-4a13-8cf6-62a67d684189", "name": "load_p1rlv10563_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8a10822-398f-441e-a5ca-73303d832183"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e761bf5d-8dac-40fe-bcc1-784c02d7c9e0"}}}}, {"uuid": "2bb093c4-e0e8-4fbe-b20d-2c543a778bb4", "name": "882a7e93-5e51-4249-ad96-1a17e1d7aef4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6295328634326751, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9988748196040309, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ec28bff4-9338-43fc-be62-87fa847f6b55", "name": "1c446171-7668-4308-bfea-5de0daefc0d8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2bb093c4-e0e8-4fbe-b20d-2c543a778bb4"}}}]}, {"uuid": "1f8e033b-4c97-4409-a9ed-ef376cf47405", "name": "load_p1rlv10563_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8a10822-398f-441e-a5ca-73303d832183"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ec28bff4-9338-43fc-be62-87fa847f6b55"}}}}, {"uuid": "1f09440e-cd9a-4892-8523-67a089753aaa", "name": "f3ba15c3-6897-4cf9-b966-1be649810e54_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.140962173014189, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10805830108563602, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d6e738d1-f311-47c7-8ff0-3779b081757e", "name": "0f67960a-e395-41cb-a379-2cf8e66d43c4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1f09440e-cd9a-4892-8523-67a089753aaa"}}}]}, {"uuid": "63d2901e-e1f7-46b7-9244-31a4776e7c0a", "name": "load_p1rlv10573_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94677ede-fd5c-4fbb-bfcd-98cf67b56913"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d6e738d1-f311-47c7-8ff0-3779b081757e"}}}}, {"uuid": "4f079056-6c3e-4ff4-a67f-efe20d6a13e6", "name": "7b2273a6-6447-4fb9-916b-ff2a0a658219_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.140962173014189, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10805830108563602, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0aca7f90-a560-460a-9f18-8ba07af4701d", "name": "3aec8eb6-8ec5-4038-9e34-f5081eae467d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4f079056-6c3e-4ff4-a67f-efe20d6a13e6"}}}]}, {"uuid": "072eddd9-9ee0-4cee-894b-68a9ea4c645b", "name": "load_p1rlv10573_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94677ede-fd5c-4fbb-bfcd-98cf67b56913"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0aca7f90-a560-460a-9f18-8ba07af4701d"}}}}, {"uuid": "73e7c137-a605-4cb7-bbf3-26cdeed2315f", "name": "87f74108-c47a-4732-8a5e-ba596786e074_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6027984746974515, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12293402966163972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ba9cf4ad-f3fd-4227-a19b-2aaad62123f8", "name": "22278bf8-f8dd-4f1c-ab87-9b73b7dbe1d7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "73e7c137-a605-4cb7-bbf3-26cdeed2315f"}}}]}, {"uuid": "4f33ad95-2a70-4770-a098-910ca9f52b56", "name": "load_p1rlv10574_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b4caeee-6304-4a25-a7d8-44c6014b5e37"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ba9cf4ad-f3fd-4227-a19b-2aaad62123f8"}}}}, {"uuid": "875f2236-e580-4421-bef0-f41c0eed5036", "name": "d4a9c871-3f9d-48a9-a724-ec5889420a13_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6027984746974515, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12293402966163972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "98ae50de-25e8-45e5-9aaf-3f1a06befbc1", "name": "dd6ab7a6-3919-4a87-995c-03d757d7f8e2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "875f2236-e580-4421-bef0-f41c0eed5036"}}}]}, {"uuid": "f9a00871-20ba-4f21-bebb-33613bf841e2", "name": "load_p1rlv10574_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b4caeee-6304-4a25-a7d8-44c6014b5e37"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "98ae50de-25e8-45e5-9aaf-3f1a06befbc1"}}}}, {"uuid": "091bf3dc-4ce0-4c92-b4f3-148a0f482cdf", "name": "dc3fc21e-dadf-45ba-8bec-19f14fc3a3c7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.535252812300099, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.708042162201308, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "424df63a-d4c4-49df-9896-f4bf2b07c473", "name": "228ebb4b-92bf-41c6-9d2b-4a7c1797794f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "091bf3dc-4ce0-4c92-b4f3-148a0f482cdf"}}}]}, {"uuid": "cfbdf53b-5867-474e-b60c-f40634e804eb", "name": "load_p1rlv10576_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25141e20-0a65-4905-b37f-954ed1a8751c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "424df63a-d4c4-49df-9896-f4bf2b07c473"}}}}, {"uuid": "7019b336-5d5d-484f-b921-9e5aca1d3c6d", "name": "59fe0be2-26b2-41b7-bdc7-7ba3350faf0f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.535252812300099, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.708042162201308, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8cee5bc4-c540-4440-ad24-55b653fd412a", "name": "b4b37538-0702-4489-94ad-1451bdbccbff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7019b336-5d5d-484f-b921-9e5aca1d3c6d"}}}]}, {"uuid": "f9ccbd09-813c-4072-bc2f-1aa56b889574", "name": "load_p1rlv10576_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25141e20-0a65-4905-b37f-954ed1a8751c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8cee5bc4-c540-4440-ad24-55b653fd412a"}}}}, {"uuid": "ce073e85-7f43-43d1-88c2-155ddf7a246d", "name": "00f06c4c-ddc4-4abf-afb5-bdceb596c710_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.261177426225613, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7908181369947367, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a8f9af20-7f19-4bf7-be41-a37c69963df6", "name": "702b8ae1-6285-494d-b679-55db28da0e5f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ce073e85-7f43-43d1-88c2-155ddf7a246d"}}}]}, {"uuid": "32de3124-470c-493e-8a0b-1157ef1af7ae", "name": "load_p1rlv10582_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdfa726f-5606-4ae2-b358-ad664dd7b0e3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a8f9af20-7f19-4bf7-be41-a37c69963df6"}}}}, {"uuid": "f9edb153-baa9-45c1-a696-5e44278f86b3", "name": "ad721249-ca51-45d8-962e-0a9e773e5d9d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.261177426225613, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7908181369947367, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "baaa64b4-3737-4051-9f0b-9d3727462fde", "name": "44ff648c-5a1e-45c3-89bb-8ace748e5de5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f9edb153-baa9-45c1-a696-5e44278f86b3"}}}]}, {"uuid": "442c6a76-1f2b-444a-9201-70b55cf27e61", "name": "load_p1rlv10582_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdfa726f-5606-4ae2-b358-ad664dd7b0e3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "baaa64b4-3737-4051-9f0b-9d3727462fde"}}}}, {"uuid": "33441858-6598-49d0-8453-71c6d90501c5", "name": "1e4ff4e9-c297-4aa5-84e2-f849bcffb5d2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "506125d1-1fed-441c-a96c-ff7cc5ab005f", "name": "8a782648-1632-4447-8a78-89d4d790e3c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "33441858-6598-49d0-8453-71c6d90501c5"}}}]}, {"uuid": "b419a8f6-93e5-4c8f-96c2-6e7960421ba5", "name": "load_p1rlv10583_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0431d17-75da-48c1-965c-875f61b0e9bf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "506125d1-1fed-441c-a96c-ff7cc5ab005f"}}}}, {"uuid": "46ae0867-dcb5-467b-8c07-d3a5302c3791", "name": "010b32c2-c545-4787-be8e-2f7c02fb95ad_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b8dd710d-416d-4930-9f88-b0fefa62cea2", "name": "e09b0ffd-aa74-4154-815a-e46564fce253", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "46ae0867-dcb5-467b-8c07-d3a5302c3791"}}}]}, {"uuid": "9e6b3a5b-3f3a-4880-ba5f-dae0d358a4e7", "name": "load_p1rlv10583_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0431d17-75da-48c1-965c-875f61b0e9bf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b8dd710d-416d-4930-9f88-b0fefa62cea2"}}}}, {"uuid": "a71bb0d6-7cd5-4cb0-aa39-4b03fcbf501f", "name": "6e85531c-5724-434e-bf41-258885a0b74e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.283752349161772, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1583018658461228, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a14c57e3-8928-429f-b8b6-434759fd2792", "name": "05c4c798-47ad-4584-b26d-777b063fcd5b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a71bb0d6-7cd5-4cb0-aa39-4b03fcbf501f"}}}]}, {"uuid": "affed099-9528-466f-9ba6-f50f7bd56991", "name": "load_p1rlv10586_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfbe5665-c020-455a-addc-d3f9514735ed"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a14c57e3-8928-429f-b8b6-434759fd2792"}}}}, {"uuid": "706a7727-9c14-44bb-9f42-f5769b154fbf", "name": "0f2287e2-6648-4316-a7e5-c85a81a46ccb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.283752349161772, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1583018658461228, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "65400728-b7be-4d80-bb6e-68e381270709", "name": "50ffc628-e234-4147-8964-d3c900648e60", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "706a7727-9c14-44bb-9f42-f5769b154fbf"}}}]}, {"uuid": "aca6ee26-2121-4078-a1fb-7eefb2af7234", "name": "load_p1rlv10586_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfbe5665-c020-455a-addc-d3f9514735ed"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "65400728-b7be-4d80-bb6e-68e381270709"}}}}, {"uuid": "998df9b0-50aa-4706-962c-b6a9c63af559", "name": "d8a9d3c7-8558-4027-ab66-7f6ca44c0b08_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.580529910152944, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3492768846801997, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f740fd31-5393-4c25-9cbd-5143edc3f377", "name": "865924bd-36b9-4409-8ca2-1d232656ec43", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "998df9b0-50aa-4706-962c-b6a9c63af559"}}}]}, {"uuid": "98a2757d-3c5d-47f5-a5ef-a267cb357eac", "name": "load_p1rlv10589_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53019a8a-b453-4add-9d2d-e4ab380fce67"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f740fd31-5393-4c25-9cbd-5143edc3f377"}}}}, {"uuid": "c736f350-7e92-4bcd-a808-503bf3dded9c", "name": "8e8b7b9b-4a12-48fd-a14c-20c44555255a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.580529910152944, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3492768846801997, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "179147ef-6495-4bc7-9ace-5174b9ffd0fb", "name": "c488a22b-700a-4256-a5a1-a4d9e1d21a6e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c736f350-7e92-4bcd-a808-503bf3dded9c"}}}]}, {"uuid": "b467a724-c9b6-4c0a-90eb-b75a3fd0f403", "name": "load_p1rlv10589_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53019a8a-b453-4add-9d2d-e4ab380fce67"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "179147ef-6495-4bc7-9ace-5174b9ffd0fb"}}}}, {"uuid": "e0c1e9bf-a608-43ec-b3ab-ff05515704f1", "name": "30465b35-19b7-4740-949a-2d5f1389c11f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.781684048838155, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7643971440160673, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0924a091-904d-42f7-b649-d8c4e062b684", "name": "ec220ee0-75c1-431e-9f5d-98b007931647", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e0c1e9bf-a608-43ec-b3ab-ff05515704f1"}}}]}, {"uuid": "43b43c8c-05dc-4444-9fed-3c3eea1e50be", "name": "load_p1rlv10596_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aad9ea92-9403-4ac0-9aaf-7e845b8c7bb5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0924a091-904d-42f7-b649-d8c4e062b684"}}}}, {"uuid": "212866d9-892a-44ab-9d78-1fa02458a3cc", "name": "f82a8ffb-3899-42d7-8198-177451892f51_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.781684048838155, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7643971440160673, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "516ee468-42ac-4367-941a-45593dd976de", "name": "b737aa9d-6fdd-472a-913f-78c8fe79ed87", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "212866d9-892a-44ab-9d78-1fa02458a3cc"}}}]}, {"uuid": "7b7838ce-89c4-413f-9761-111972a4b000", "name": "load_p1rlv10596_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aad9ea92-9403-4ac0-9aaf-7e845b8c7bb5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "516ee468-42ac-4367-941a-45593dd976de"}}}}, {"uuid": "4d25b7f3-e1e0-432c-bbd2-20c4982bffda", "name": "b7d458c4-81f5-4535-9a34-c06bdafbc719_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.133667846972055, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2625504562375869, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "291e100a-66a8-41c0-bb8e-9d18f760f9dc", "name": "2aa56bbc-393b-4963-891e-67d320f18d6c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4d25b7f3-e1e0-432c-bbd2-20c4982bffda"}}}]}, {"uuid": "7fd0a1eb-8e77-42a0-8a43-1990b29e2e1a", "name": "load_p1rlv10600_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "feb19590-c5f4-4982-9e99-20599f08cfe7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "291e100a-66a8-41c0-bb8e-9d18f760f9dc"}}}}, {"uuid": "93c34184-8439-410b-ab1a-54995d21afe4", "name": "1d458fa6-b09d-4bc8-ade0-0eaf6f62856b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.133667846972055, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2625504562375869, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8afd019e-2169-40ea-b70e-02b9578356bb", "name": "207faf6b-8f69-40e4-97fe-33d345d76c58", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "93c34184-8439-410b-ab1a-54995d21afe4"}}}]}, {"uuid": "e6bf0bb1-8209-47b9-9304-84e1a3ec0e95", "name": "load_p1rlv10600_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "feb19590-c5f4-4982-9e99-20599f08cfe7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8afd019e-2169-40ea-b70e-02b9578356bb"}}}}, {"uuid": "b5dece36-50a7-4842-bbf9-9cdcf07baef7", "name": "8767fde3-ad7a-414e-bc9e-ca67510d2a2c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.35395787140957025, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.14845654114897794, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "71bb45c2-d377-4a99-a4d5-f04aab1c26a7", "name": "1a4c4159-647d-4a55-940a-3d3bc5b56df3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5dece36-50a7-4842-bbf9-9cdcf07baef7"}}}]}, {"uuid": "962db928-09f8-4d43-9e77-fd32dd920c61", "name": "load_p1rlv10610_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b91354e-ce50-44d0-a959-fa451bb9cf20"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "71bb45c2-d377-4a99-a4d5-f04aab1c26a7"}}}}, {"uuid": "3b307419-3523-499b-8ab5-3e84ec6d323b", "name": "bb104de1-36db-46bf-81e0-7ebfe6c1d871_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.35395787140957025, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.14845654114897794, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c328b7ae-4b82-457d-8a1a-9810e282362a", "name": "376a780a-f7e2-4b6a-9e1c-adbbc7cad426", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3b307419-3523-499b-8ab5-3e84ec6d323b"}}}]}, {"uuid": "295f6e77-8da3-43b6-8193-d01761e2adff", "name": "load_p1rlv10610_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b91354e-ce50-44d0-a959-fa451bb9cf20"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c328b7ae-4b82-457d-8a1a-9810e282362a"}}}}, {"uuid": "5a920664-46e5-44a4-abf9-38560768e114", "name": "fc0d786d-53e1-449d-9803-734d144740c8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9149869461814677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5767582022429075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "47fe32f7-b3b9-4ee4-902c-48cc953c93f6", "name": "e6cb8855-dec5-415f-911d-297d7831ccb9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5a920664-46e5-44a4-abf9-38560768e114"}}}]}, {"uuid": "3da235eb-7577-4aab-8863-c8474cb6de00", "name": "load_p1rlv10615_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b175fcb-d1ee-44eb-8f89-826e40c5db1d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "47fe32f7-b3b9-4ee4-902c-48cc953c93f6"}}}}, {"uuid": "4d15b95c-82d8-4b91-aeb5-50fbe216e6de", "name": "f61c42da-6a48-4219-ab9b-8fc1f38764dd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9149869461814677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5767582022429075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8c4eedf7-f50b-42fd-8871-6790d0feb8a4", "name": "c9fda510-ad07-4e41-a244-893e99990fa6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4d15b95c-82d8-4b91-aeb5-50fbe216e6de"}}}]}, {"uuid": "6601651a-f399-4530-9b0b-c9fd05796b8e", "name": "load_p1rlv10615_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b175fcb-d1ee-44eb-8f89-826e40c5db1d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8c4eedf7-f50b-42fd-8871-6790d0feb8a4"}}}}, {"uuid": "2b7045b6-1362-42cf-bb6c-31cf6d4cae79", "name": "ed9bb46e-4447-4388-b0d3-1b09ad2dc42d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7464189326227366, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4011494318939581, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bec56e7a-528d-4b92-b5d0-486b1cbee7fc", "name": "a26888a3-858e-406b-ac7a-2ab68649b0c6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2b7045b6-1362-42cf-bb6c-31cf6d4cae79"}}}]}, {"uuid": "236e5d7e-1f9a-461d-844a-39414ced353d", "name": "load_p1rlv10616_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a5717e0-080e-46ae-918a-64fe4fcba5d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bec56e7a-528d-4b92-b5d0-486b1cbee7fc"}}}}, {"uuid": "4e4ad82d-6794-4073-ac45-9bf871ccf4c6", "name": "ce82cb31-9d2e-498a-a992-9599980183e2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7464189326227366, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4011494318939581, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a2a28822-0c17-4424-bb12-be4aa4b6af2a", "name": "24e55c3b-f642-4d33-84ba-33e0d4172e30", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4e4ad82d-6794-4073-ac45-9bf871ccf4c6"}}}]}, {"uuid": "43c97500-210e-4c50-abff-6d9608e600f9", "name": "load_p1rlv10616_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a5717e0-080e-46ae-918a-64fe4fcba5d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a2a28822-0c17-4424-bb12-be4aa4b6af2a"}}}}, {"uuid": "463f6149-b5d4-438f-a16d-4586f0bc0a43", "name": "422be16a-bf20-40ce-ad49-3394e9c866a2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.316539553342243, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9980015331306656, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d6cd3808-bd69-4b1c-a105-5654fa60cf31", "name": "91573b38-6c73-490f-82a5-e86402cf9f87", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "463f6149-b5d4-438f-a16d-4586f0bc0a43"}}}]}, {"uuid": "29eea145-22f9-4150-94ad-3764b540ef65", "name": "load_p1rlv10621_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "374d5417-b2c4-4d16-9b91-d2f519921fd8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d6cd3808-bd69-4b1c-a105-5654fa60cf31"}}}}, {"uuid": "1644862a-e0b2-4ebb-830d-5aa02ef2083c", "name": "029f2c31-f226-4c23-bfc7-08d84532d0e7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.316539553342243, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9980015331306656, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0d6655f1-c352-4e7b-980a-9045ce071e1e", "name": "a1e08948-18d1-4591-9457-112ac5261a7e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1644862a-e0b2-4ebb-830d-5aa02ef2083c"}}}]}, {"uuid": "2ed5b3ea-f3ae-475e-8aa6-c5bfe5aa1b73", "name": "load_p1rlv10621_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "374d5417-b2c4-4d16-9b91-d2f519921fd8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0d6655f1-c352-4e7b-980a-9045ce071e1e"}}}}, {"uuid": "c31478e6-d929-4e98-b045-c71b4087ad9e", "name": "c06ea238-dd56-4f76-a18a-9b96099385f1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.45600682921886, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9975893759791478, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7b0fcda8-4fd9-4888-a3c8-7a064f3a0514", "name": "20858e21-f5be-4bc2-a069-a8068e7695f4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c31478e6-d929-4e98-b045-c71b4087ad9e"}}}]}, {"uuid": "9ee800d6-2926-45c5-b6d4-172a40ee6b6e", "name": "load_p1rlv10627_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32406d7d-51f9-4c16-900b-526985e5f62b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7b0fcda8-4fd9-4888-a3c8-7a064f3a0514"}}}}, {"uuid": "8d18bbd5-8fcc-4978-8b60-29e2529c0513", "name": "6ae0e2e9-df9d-4148-97f8-233de83aa4f4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.45600682921886, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9975893759791478, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4b6b3d03-cac6-4782-b4c3-d9055a264d8b", "name": "db365dd3-dfa0-4c92-9bfc-e5963b6beced", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8d18bbd5-8fcc-4978-8b60-29e2529c0513"}}}]}, {"uuid": "a2c989ea-ede9-4302-b016-020257901a81", "name": "load_p1rlv10627_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32406d7d-51f9-4c16-900b-526985e5f62b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4b6b3d03-cac6-4782-b4c3-d9055a264d8b"}}}}, {"uuid": "653ced00-1a70-4461-a7f6-a46782d611fb", "name": "b0d67803-8e00-442d-b29d-be88928222a0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.625789834877447, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.7705314525486966, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f000b9e4-f294-460c-9c34-682dee4dd32f", "name": "8089d052-21f9-42c0-a786-82669cbf06ec", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "653ced00-1a70-4461-a7f6-a46782d611fb"}}}]}, {"uuid": "7bbb89a7-837a-40c9-81e6-6140afcbb9bc", "name": "load_p1rlv10629_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e183b3e8-d995-4f1e-baee-8d9d4add157e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f000b9e4-f294-460c-9c34-682dee4dd32f"}}}}, {"uuid": "c75500b4-b35d-407d-8f47-15b6ddee22c7", "name": "6a8d26b5-3a9c-429a-9e31-330ff08e2951_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.625789834877447, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.7705314525486966, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e561abf6-354f-47f3-b5b8-2822f6d8891b", "name": "9627e5cb-4670-4bea-8f37-6b4ac968697f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c75500b4-b35d-407d-8f47-15b6ddee22c7"}}}]}, {"uuid": "d30485b2-f695-4972-b2a0-8205cb6a63c6", "name": "load_p1rlv10629_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e183b3e8-d995-4f1e-baee-8d9d4add157e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e561abf6-354f-47f3-b5b8-2822f6d8891b"}}}}, {"uuid": "0be7dab3-4ef7-4396-908e-c67399cca48a", "name": "bdcfe216-985a-423d-a716-8996ebdea531_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.125662061080136, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6733739749908499, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "28e783ef-c07f-4016-a491-53d49ddc21c8", "name": "26f86049-1b09-4339-ac49-8d0f10195020", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0be7dab3-4ef7-4396-908e-c67399cca48a"}}}]}, {"uuid": "09da0e23-f708-49f8-b813-bda8c90d15ae", "name": "load_p1rlv10630_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d60a935-dc9b-48ea-8ee7-9b682452035e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "28e783ef-c07f-4016-a491-53d49ddc21c8"}}}}, {"uuid": "c647e0fd-2e92-431a-8bb0-efebf3669424", "name": "b698fe6e-a967-423a-be37-144d8a5edea4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.125662061080136, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6733739749908499, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b71ca818-e973-4c59-9900-3bf0adb156fa", "name": "314aeea4-6250-4fa3-a96c-542ebc6e63f0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c647e0fd-2e92-431a-8bb0-efebf3669424"}}}]}, {"uuid": "5785d1c0-ba23-47eb-8707-a652c3394c89", "name": "load_p1rlv10630_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d60a935-dc9b-48ea-8ee7-9b682452035e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b71ca818-e973-4c59-9900-3bf0adb156fa"}}}}, {"uuid": "28b97377-d18d-4b60-9fca-e275e912c1c0", "name": "1eb51cbf-a614-4010-8d85-3031944396ef_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4699462180170992, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3815978523472859, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a04d5ba8-580f-4c23-afea-273c028b13a0", "name": "3ca967da-a3b3-44f3-a92f-2c7122f74989", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "28b97377-d18d-4b60-9fca-e275e912c1c0"}}}]}, {"uuid": "bb0803a9-ffed-4930-85ac-23fc778bea77", "name": "load_p1rlv10634_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3184f056-3b5f-403d-86a0-f9b28d6bb3e3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a04d5ba8-580f-4c23-afea-273c028b13a0"}}}}, {"uuid": "a7f4f6a8-df1c-44b1-9861-e21c9ec35731", "name": "9b69478f-847b-4ba5-9717-b8f663214aff_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4699462180170992, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3815978523472859, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "955bb2fc-75c9-456e-b65a-14916d6ced7b", "name": "2527f77e-53d9-412a-a32a-f3ea5d666ff1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a7f4f6a8-df1c-44b1-9861-e21c9ec35731"}}}]}, {"uuid": "b95dbc99-087a-46b2-bee8-c253dafd753a", "name": "load_p1rlv10634_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3184f056-3b5f-403d-86a0-f9b28d6bb3e3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "955bb2fc-75c9-456e-b65a-14916d6ced7b"}}}}, {"uuid": "a027f1ba-5e36-4e14-8867-e8750b9b3e88", "name": "77d960dd-6e4b-4835-af96-4ff160700260_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.444725768387703, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6902267912659802, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "751a9fe0-cc15-4d54-976f-9c9b44796aa8", "name": "f869e91b-9bbd-41eb-b0d9-b723b1f74a78", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a027f1ba-5e36-4e14-8867-e8750b9b3e88"}}}]}, {"uuid": "074c693a-da67-459d-b817-3848a9649671", "name": "load_p1rlv10637_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9510bd0-2bba-4522-bfbe-20b94ea400b6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "751a9fe0-cc15-4d54-976f-9c9b44796aa8"}}}}, {"uuid": "70233a64-93d7-48a5-a06f-0600b5583265", "name": "97d43e0e-f26c-4fdc-ba4f-dbe0fac30736_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.444725768387703, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6902267912659802, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e046118c-7973-4191-a90f-8d40c5b13230", "name": "da65b232-5e9a-486f-a95b-08db42c934d3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "70233a64-93d7-48a5-a06f-0600b5583265"}}}]}, {"uuid": "78a39f4f-3259-49ea-a016-d0b6b770a82a", "name": "load_p1rlv10637_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9510bd0-2bba-4522-bfbe-20b94ea400b6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e046118c-7973-4191-a90f-8d40c5b13230"}}}}, {"uuid": "fadd79c0-580a-4d5e-9b5e-4da9d0191025", "name": "421e5657-d3b4-4c77-910e-a3470738ed61_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.639205904339139, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.495473092652384, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "296cc9cb-beef-41c6-ae8e-7d039b1b7402", "name": "ca951ebf-49ea-4e9c-926c-27e69045a428", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fadd79c0-580a-4d5e-9b5e-4da9d0191025"}}}]}, {"uuid": "83f977da-d0de-4535-baeb-367c8d9a3bed", "name": "load_p1rlv10641_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73ada6ad-ace7-46c1-80f7-2cb33cf4cdb3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "296cc9cb-beef-41c6-ae8e-7d039b1b7402"}}}}, {"uuid": "6244ef9d-3ee0-4a79-a3cf-e130b5de1618", "name": "082e46e7-c3cd-4225-8e60-096b9eb9a590_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.639205904339139, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.495473092652384, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "521f0d48-d008-471b-b45d-f7bf007a4ceb", "name": "ca87f831-2281-423e-803b-1aac098aaabb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6244ef9d-3ee0-4a79-a3cf-e130b5de1618"}}}]}, {"uuid": "6bb625d2-9233-43f7-8321-cfc6b33e6e72", "name": "load_p1rlv10641_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73ada6ad-ace7-46c1-80f7-2cb33cf4cdb3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "521f0d48-d008-471b-b45d-f7bf007a4ceb"}}}}, {"uuid": "f91053fa-fba9-4b1a-94f3-b5dfda7e789f", "name": "55e3c28f-a550-42dc-b7cc-cb2f5f0dddfd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5996895391512607, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5332968923160806, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "da312d03-f181-4ea8-8476-b4e00dc50cb3", "name": "67cf474e-c021-428e-a983-8816bde7e8f8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f91053fa-fba9-4b1a-94f3-b5dfda7e789f"}}}]}, {"uuid": "e3969318-5b8f-4511-815b-c97286011e74", "name": "load_p1rlv10663_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8198c1c5-67e0-49b9-b11a-1f266f7f4bcb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "da312d03-f181-4ea8-8476-b4e00dc50cb3"}}}}, {"uuid": "6957f6ed-5631-42d6-9d60-cee07aa633d1", "name": "a2574217-f0bc-401c-aa12-2fe1c5ab5bb8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5996895391512607, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5332968923160806, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "85f0f261-6c1b-4794-ac26-c0f8f6be3265", "name": "da6eba67-b155-4618-ae2b-bf28e68e16c8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6957f6ed-5631-42d6-9d60-cee07aa633d1"}}}]}, {"uuid": "90ca281a-a8a7-4109-9b92-b7053ff76551", "name": "load_p1rlv10663_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8198c1c5-67e0-49b9-b11a-1f266f7f4bcb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "85f0f261-6c1b-4794-ac26-c0f8f6be3265"}}}}, {"uuid": "364ef7a1-6b22-425f-aa38-1667cc9652de", "name": "b02ac72c-6bab-4491-a7df-9856c068a576_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9149869461814677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5767582022429075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "12c2a122-0ec2-4129-90ee-9a330e839fb7", "name": "a142bbc2-148a-4fa0-be13-8a785682e3e2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "364ef7a1-6b22-425f-aa38-1667cc9652de"}}}]}, {"uuid": "e5b3e471-5f92-44ad-b659-16e3ab78dcf4", "name": "load_p1rlv10720_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3d48c0e-704d-4205-94a2-ee74be7ae350"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "12c2a122-0ec2-4129-90ee-9a330e839fb7"}}}}, {"uuid": "2ebeaab4-4842-4216-bd44-71dc5c2a7f6f", "name": "c7a07059-5ecf-411b-bee2-5ceb38f53633_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9149869461814677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5767582022429075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "41144dbe-6edf-48e6-931c-82121205ff38", "name": "212c5a0a-514f-4b2c-8912-4cef4b7adb80", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2ebeaab4-4842-4216-bd44-71dc5c2a7f6f"}}}]}, {"uuid": "d4f4e6d2-0731-455b-a58f-11e4d5d1b78e", "name": "load_p1rlv10720_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3d48c0e-704d-4205-94a2-ee74be7ae350"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "41144dbe-6edf-48e6-931c-82121205ff38"}}}}, {"uuid": "7049ada4-9114-4342-95bf-162266ecb2ba", "name": "209d18ad-3da4-4a0a-a18d-139fd7eff92e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.459276697523187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8425022918187992, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b16a6e95-c8f5-4782-94af-ed256de9d106", "name": "bb9c6d31-7bb7-4c8a-b7fc-eb53006db484", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7049ada4-9114-4342-95bf-162266ecb2ba"}}}]}, {"uuid": "a45093a1-aeb2-4aad-9a1c-57eef425994a", "name": "load_p1rlv10955_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75dbf8f0-4cb6-49b7-a2a5-f98e9ff4b8df"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b16a6e95-c8f5-4782-94af-ed256de9d106"}}}}, {"uuid": "da9d1374-3cb5-497a-97ba-27c9750ad746", "name": "0730f85a-c922-453d-bd82-9ee41aa7376d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.459276697523187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8425022918187992, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "08eb6627-ce4a-4673-957c-3df6796e63f0", "name": "b114394d-af7c-435f-ad7a-d1779837681a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "da9d1374-3cb5-497a-97ba-27c9750ad746"}}}]}, {"uuid": "d03d68b7-65eb-4249-be52-dd2a1dbe7650", "name": "load_p1rlv10955_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75dbf8f0-4cb6-49b7-a2a5-f98e9ff4b8df"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "08eb6627-ce4a-4673-957c-3df6796e63f0"}}}}, {"uuid": "f40aa2e5-798f-468f-93f9-958f2ae92bfd", "name": "811e6f6f-9ece-4150-80f3-983552fe8aac_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.42648220197083947, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17627708866943506, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e8a38e5e-7db6-4ecb-b58c-9dcaac9f11eb", "name": "71370420-00b4-4479-aee6-1c11890b72a5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f40aa2e5-798f-468f-93f9-958f2ae92bfd"}}}]}, {"uuid": "e5e82ab0-0cc3-4445-a080-eff62f94cd34", "name": "load_p1rlv11048_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a8fc823-6fe8-4a3b-9437-68aa751f5e3b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e8a38e5e-7db6-4ecb-b58c-9dcaac9f11eb"}}}}, {"uuid": "1013b4ee-68cb-4342-936f-ce6ebcddd288", "name": "b1fd9cc5-31c7-4176-b403-2656e3c2ce7a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.42648220197083947, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17627708866943506, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b678eeac-b15d-4766-8549-1eb6d5dc61bf", "name": "474536a9-ccf9-4eb4-9c23-35857083a349", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1013b4ee-68cb-4342-936f-ce6ebcddd288"}}}]}, {"uuid": "65b91a42-c72a-48d4-a306-71c83189ddca", "name": "load_p1rlv11048_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a8fc823-6fe8-4a3b-9437-68aa751f5e3b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b678eeac-b15d-4766-8549-1eb6d5dc61bf"}}}}, {"uuid": "8bb152c5-aaf8-40a7-8604-4360a5122b95", "name": "e31634b5-7017-47ab-b867-88b81e3a7163_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0788570276665777, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5949433355568994, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cf79dcb8-43f9-49d0-ab1e-f6e5cd137ec8", "name": "ea8a6cc2-20d2-42ad-a5cb-78d22731cb1c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8bb152c5-aaf8-40a7-8604-4360a5122b95"}}}]}, {"uuid": "ee8dcbf3-9e3a-431f-9108-40418a72d162", "name": "load_p1rlv11380_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f949a06a-817e-4666-95bb-9536ce06a694"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cf79dcb8-43f9-49d0-ab1e-f6e5cd137ec8"}}}}, {"uuid": "9fb0c3ac-d337-4dde-bedc-2f4bbba5ddef", "name": "f5c2b463-2dea-4336-8db0-a1001296e30a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0788570276665777, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5949433355568994, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5508212d-10cb-4e84-a89a-a39c0ba9e6e7", "name": "5db1c0a2-9f61-413e-b9fc-253e73f7889b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9fb0c3ac-d337-4dde-bedc-2f4bbba5ddef"}}}]}, {"uuid": "2dcd8ef1-01fd-44a8-af9e-6a40ebde70ab", "name": "load_p1rlv11380_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f949a06a-817e-4666-95bb-9536ce06a694"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5508212d-10cb-4e84-a89a-a39c0ba9e6e7"}}}}, {"uuid": "f11640f5-490c-4a9d-adbe-3a2bddcc1d95", "name": "630809d5-43e2-4522-b987-732d50a76bca_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.122083974307247, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.832996158964583, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "278ca58d-0aec-48ce-8f6d-022a2552ce18", "name": "ae7fadf0-a2dc-452a-a866-31b4daec1911", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f11640f5-490c-4a9d-adbe-3a2bddcc1d95"}}}]}, {"uuid": "34642993-ddc9-4c08-bf35-b04592e73168", "name": "load_p1rlv11384_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0c23aea-471f-4d10-9500-1bc14a67d7e7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "278ca58d-0aec-48ce-8f6d-022a2552ce18"}}}}, {"uuid": "360fefe8-8b88-4807-aa47-17a5de0df06d", "name": "d0ae83c6-a7c4-4e1a-95e5-bebea8ece424_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.122083974307247, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.832996158964583, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3bb00d31-4128-4f55-bdd8-9a989ab63a16", "name": "cd66eb38-760d-4dac-9177-b9385426979f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "360fefe8-8b88-4807-aa47-17a5de0df06d"}}}]}, {"uuid": "1431994c-a7e8-4e06-8ba2-4384f422d5b7", "name": "load_p1rlv11384_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0c23aea-471f-4d10-9500-1bc14a67d7e7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3bb00d31-4128-4f55-bdd8-9a989ab63a16"}}}}, {"uuid": "526a60db-5260-4cfe-a3d6-ce7cbc422a6b", "name": "cbaffa95-fa01-45a7-99ef-34477a88115a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 10.509020108523046, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.6522347064707315, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "79136e75-b2b8-4bd4-9360-0d672af1e684", "name": "55cb41d2-e75a-414e-8893-9f575d733c50", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "526a60db-5260-4cfe-a3d6-ce7cbc422a6b"}}}]}, {"uuid": "0cf0d892-3e55-4a93-a396-6b5d00cba278", "name": "load_p1rlv11385_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2115e8bb-fe49-49ad-8687-68feca212557"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "79136e75-b2b8-4bd4-9360-0d672af1e684"}}}}, {"uuid": "b2722973-8fe5-41d6-856b-01957ca2efb6", "name": "4c8dfd26-9575-44c2-8877-ec3dceddecec_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 10.509020108523046, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.6522347064707315, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c3a4d236-5526-4eaf-b69c-81f9f7b57cb6", "name": "eb107080-b20d-42c3-9e00-87dc33942c0e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b2722973-8fe5-41d6-856b-01957ca2efb6"}}}]}, {"uuid": "899f5896-8be0-4757-b0be-e3235ceff34b", "name": "load_p1rlv11385_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2115e8bb-fe49-49ad-8687-68feca212557"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c3a4d236-5526-4eaf-b69c-81f9f7b57cb6"}}}}, {"uuid": "98be4d9c-2302-41b6-9f5b-4124b7bedc5b", "name": "be52d5eb-3fdd-4f36-bc38-914bdf52b39f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.480517361983766, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0183082338731784, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e52315c8-e7e3-4682-8066-90ef82614883", "name": "0259a1c5-11af-4e90-a192-7575b8ccd45d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "98be4d9c-2302-41b6-9f5b-4124b7bedc5b"}}}]}, {"uuid": "4c2cd8dc-dc30-464f-a4f6-ae32fbbd247e", "name": "load_p1rlv11386_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f512d86-c9d9-4f58-9d5a-418d0732dc94"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e52315c8-e7e3-4682-8066-90ef82614883"}}}}, {"uuid": "9efa0853-fb2f-400c-ad76-17bc96185208", "name": "2d808018-f753-4122-8b76-c102272718fc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.480517361983766, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0183082338731784, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "78a80a75-a6a5-4450-b3a2-26efb704dc06", "name": "6a48081b-2edc-4ef6-96ff-51221e6a3bb5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9efa0853-fb2f-400c-ad76-17bc96185208"}}}]}, {"uuid": "f3b9c812-99d0-42c0-aaba-a48a0440d18c", "name": "load_p1rlv11386_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f512d86-c9d9-4f58-9d5a-418d0732dc94"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "78a80a75-a6a5-4450-b3a2-26efb704dc06"}}}}, {"uuid": "449a0c3d-1ba5-4099-9a54-1e94666184c9", "name": "16305d34-b9f3-4562-b126-f1a81d200b85_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4651344294517608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7736313908316925, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e7421110-4b71-4cca-9a89-108b52acf66b", "name": "16ac7d63-c464-4a44-91d6-7f7731be9d2b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "449a0c3d-1ba5-4099-9a54-1e94666184c9"}}}]}, {"uuid": "18607566-7803-4c38-875a-dcd43eb95cda", "name": "load_p1rlv11387_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbca8c57-0da4-4368-9821-7a9ca4282173"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e7421110-4b71-4cca-9a89-108b52acf66b"}}}}, {"uuid": "28751ce9-4f0f-43d8-a5a6-82b259be16d2", "name": "048de35a-8050-4d9a-99e1-996a10b8d873_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4651344294517608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7736313908316925, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "46cf857e-b861-4c96-9ddd-8f93f3999ff3", "name": "62942fa3-ff93-4763-b6e4-7e47e0ee32a5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "28751ce9-4f0f-43d8-a5a6-82b259be16d2"}}}]}, {"uuid": "242d0f50-b01f-465a-b6ad-42e3957d6adc", "name": "load_p1rlv11387_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbca8c57-0da4-4368-9821-7a9ca4282173"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "46cf857e-b861-4c96-9ddd-8f93f3999ff3"}}}}, {"uuid": "65dcd61c-606d-40c5-ac84-5c883bfd958a", "name": "7e0228c2-e3a9-4eb2-9609-4c43c4c479a4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4359784649582454, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.14838741475370543, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b35b4c6e-6f59-4eff-bcaa-d55880e1a26c", "name": "448c1537-1044-4341-8cc4-17303fdc01f6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "65dcd61c-606d-40c5-ac84-5c883bfd958a"}}}]}, {"uuid": "061ac5e1-4491-4054-a774-49521eab7009", "name": "load_p1rlv11388_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12377bf0-f258-4c29-ab26-e938c95ee25c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b35b4c6e-6f59-4eff-bcaa-d55880e1a26c"}}}}, {"uuid": "4c928ce3-4607-4184-a739-4aec1d7d889a", "name": "2631c714-8f91-4974-becb-b4af853a819c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4359784649582454, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.14838741475370543, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bcbddbf6-2fa2-44d7-8332-a0de0780b2c5", "name": "8b212604-4f4d-4843-a575-054512258d30", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4c928ce3-4607-4184-a739-4aec1d7d889a"}}}]}, {"uuid": "8a4b10c5-a6db-4ed7-8e35-6f998a22b4ae", "name": "load_p1rlv11388_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12377bf0-f258-4c29-ab26-e938c95ee25c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bcbddbf6-2fa2-44d7-8332-a0de0780b2c5"}}}}, {"uuid": "79d552d3-cee0-4a5c-b1a2-75be1d6a51c7", "name": "3bdb2f3f-9a78-4cc3-a63c-8cf570881f21_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5261964028176471, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5335215898246958, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7a49efe3-5daa-47c4-815e-2716df97977c", "name": "5fdfa4f1-eddf-4d3d-b9d7-0e9b2936dc09", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "79d552d3-cee0-4a5c-b1a2-75be1d6a51c7"}}}]}, {"uuid": "4ddb8c43-6e0c-4309-8132-cca83f8e4659", "name": "load_p1rlv11390_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b6420b1-3456-42fc-9266-c2b84e063cec"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7a49efe3-5daa-47c4-815e-2716df97977c"}}}}, {"uuid": "44b3e1b7-6f21-40fb-90f8-ada5d654828f", "name": "b0bbc030-b3ae-48cb-add4-c76f9579a136_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5261964028176471, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5335215898246958, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a1a95b33-a327-433e-a614-fe431f7fa246", "name": "592346aa-cb58-403e-b561-9fd691bdeddb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "44b3e1b7-6f21-40fb-90f8-ada5d654828f"}}}]}, {"uuid": "8b62b715-2222-4d0f-bb32-eb15d0362481", "name": "load_p1rlv11390_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b6420b1-3456-42fc-9266-c2b84e063cec"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a1a95b33-a327-433e-a614-fe431f7fa246"}}}}, {"uuid": "559142c0-923c-48cb-a663-08acf9b99abe", "name": "edd46b4f-039e-4197-bea5-a0a193e9034c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.056520022279634, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8635401886215074, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "755f07e7-916c-4a53-8b8e-fdbe8a86ed7e", "name": "8800987f-4611-48c6-be6e-61646d7a93f9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "559142c0-923c-48cb-a663-08acf9b99abe"}}}]}, {"uuid": "2f3b07f5-6d3b-47c6-b03f-62a581a26356", "name": "load_p1rlv11392_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e740a352-ac8f-4ae2-ace3-254fccd7f96f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "755f07e7-916c-4a53-8b8e-fdbe8a86ed7e"}}}}, {"uuid": "4574b2d1-fc8e-49ff-a25a-fc07d36b301d", "name": "e63794ba-c4ae-44ae-b439-bd3343a501d5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.056520022279634, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8635401886215074, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "756fa955-9680-480f-85b2-d5b52b29f99e", "name": "083c63fe-380e-41f3-9ba3-62772e37b557", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4574b2d1-fc8e-49ff-a25a-fc07d36b301d"}}}]}, {"uuid": "59c6d232-98a9-47e1-bed2-5e872041a8d2", "name": "load_p1rlv11392_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e740a352-ac8f-4ae2-ace3-254fccd7f96f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "756fa955-9680-480f-85b2-d5b52b29f99e"}}}}, {"uuid": "462390c9-21da-4beb-9fc6-0f0467cb6409", "name": "d7557778-2990-4193-bcab-760f907a022b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6676306342135938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5123446143614628, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a15ae177-76ec-43f0-a0c2-a1026e8ec787", "name": "dae2d185-f280-4645-9d77-2ef82f12b93c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "462390c9-21da-4beb-9fc6-0f0467cb6409"}}}]}, {"uuid": "278597eb-7589-4179-9c56-8147c045a63a", "name": "load_p1rlv11394_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "996d3e44-142c-42fa-bf4f-2bd1777122dd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a15ae177-76ec-43f0-a0c2-a1026e8ec787"}}}}, {"uuid": "3b3c4397-6414-48a5-990a-6ad45810e2a0", "name": "78e01f6b-d1e6-4496-bbec-41c47850519e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6676306342135938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5123446143614628, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ddd93c03-41d9-4a3c-81c1-1ba375c6c355", "name": "e342d2f3-4b04-4da0-9630-4b32275eb7c6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3b3c4397-6414-48a5-990a-6ad45810e2a0"}}}]}, {"uuid": "ab65142c-9c13-4a8c-8cc7-b104c63b5259", "name": "load_p1rlv11394_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "996d3e44-142c-42fa-bf4f-2bd1777122dd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ddd93c03-41d9-4a3c-81c1-1ba375c6c355"}}}}, {"uuid": "06de4b0e-2909-42a2-959d-aa5a6a240436", "name": "db623204-32c1-44e5-adc3-3c160b103c96_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0716401691896973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6949594139700135, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cb377bff-e6f7-4447-8797-48e32b35cd1a", "name": "0379a339-a2ec-462f-bf7e-b2e2e2a3cc96", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "06de4b0e-2909-42a2-959d-aa5a6a240436"}}}]}, {"uuid": "1e04e619-d127-4ea3-87ed-5eb9556ac87d", "name": "load_p1rlv11395_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29922f55-f36a-4b9e-8836-5f9dadd641b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cb377bff-e6f7-4447-8797-48e32b35cd1a"}}}}, {"uuid": "58db2d51-9c85-4843-83a6-cf19e369b34f", "name": "1c0b8270-742b-4189-8212-bf9144bc65af_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0716401691896973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6949594139700135, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "35c29600-c66e-4dc1-92ab-5574ce2dfe4e", "name": "cad04e0d-401c-4383-901c-67f3f7902974", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58db2d51-9c85-4843-83a6-cf19e369b34f"}}}]}, {"uuid": "908db140-2d30-4690-96be-fe82a41c7d68", "name": "load_p1rlv11395_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29922f55-f36a-4b9e-8836-5f9dadd641b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "35c29600-c66e-4dc1-92ab-5574ce2dfe4e"}}}}, {"uuid": "d5614689-653e-472f-9267-639e0d79a5f1", "name": "fa235b5c-542f-425f-8e7d-585216fa16af_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.8145950466373417, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09093602970127403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "736b85df-cb4e-4e9b-83cf-08ae8f791c33", "name": "9d31ebe3-0876-4f4a-962e-66d5f02222c8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d5614689-653e-472f-9267-639e0d79a5f1"}}}]}, {"uuid": "eb1321da-6da4-4467-b70d-211ce256bd9d", "name": "load_p1rlv11397_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fd316b0-fd98-4193-9c1b-aaa7d92a4284"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "736b85df-cb4e-4e9b-83cf-08ae8f791c33"}}}}, {"uuid": "c9ca1464-7f8d-4a34-9c17-7bcd4af77466", "name": "32f1b799-0314-4cee-9183-a6e1d85e616a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.8145950466373417, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09093602970127403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7ec03626-15d0-482f-8e2c-732f4fa3238e", "name": "de74e497-95d5-40ed-bb4b-e8d05267a90c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9ca1464-7f8d-4a34-9c17-7bcd4af77466"}}}]}, {"uuid": "716a39f1-ba9a-4a83-b6b0-1e8b432d48ac", "name": "load_p1rlv11397_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fd316b0-fd98-4193-9c1b-aaa7d92a4284"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7ec03626-15d0-482f-8e2c-732f4fa3238e"}}}}, {"uuid": "c88b7522-4bd8-49d0-bc8e-b13cc33d39ac", "name": "ac5c5c8d-2059-4ae0-a96e-2e4ef1fc7da5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 23.859207702115498, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3391872562704328, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d557504b-7f7f-4144-bab4-599b9a9b4147", "name": "b361a8d0-1846-477b-ad03-cdb801178674", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c88b7522-4bd8-49d0-bc8e-b13cc33d39ac"}}}]}, {"uuid": "1227d484-abf8-457b-9a16-2712f4293348", "name": "load_p1rlv11398_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97aa01fe-2e60-4617-8c89-d36f425087fe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d557504b-7f7f-4144-bab4-599b9a9b4147"}}}}, {"uuid": "5095d65a-f8f9-43ad-9509-bd1a682fb4de", "name": "1fdd615c-4a8b-45df-a664-b7afad3317cc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 23.859207702115498, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3391872562704328, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1100417b-7762-42c1-84e3-9df8982977b1", "name": "67c88a92-b4bf-420a-842a-9d6c7bf6ff8b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5095d65a-f8f9-43ad-9509-bd1a682fb4de"}}}]}, {"uuid": "ab6196e1-93f6-4f4a-ba8f-dfceaed4b375", "name": "load_p1rlv11398_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97aa01fe-2e60-4617-8c89-d36f425087fe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1100417b-7762-42c1-84e3-9df8982977b1"}}}}, {"uuid": "c85d0dcd-b204-4eab-b636-4bd71b02ac73", "name": "a34faa76-5042-44d6-a7c0-7fa364a76449_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.936474762797392, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1018059929469786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "93ed52e0-29fd-47f1-bcff-9e635f2710c4", "name": "fe1551b2-4899-4058-ba17-33095af84ca7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c85d0dcd-b204-4eab-b636-4bd71b02ac73"}}}]}, {"uuid": "0dd259e1-6337-42d8-8b1a-f1167ba06871", "name": "load_p1rlv11399_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68a9eead-8197-4e82-a444-2a4544ec9ddb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "93ed52e0-29fd-47f1-bcff-9e635f2710c4"}}}}, {"uuid": "475d83d0-97e4-4073-9eb4-c4054a6a73c6", "name": "58181977-2e65-49af-bac7-75f122b75525_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.936474762797392, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1018059929469786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "412f3c1c-8bd1-4f9a-8b78-ff10d0dc33af", "name": "442532b1-69f9-4bd4-be04-fd2195a09331", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "475d83d0-97e4-4073-9eb4-c4054a6a73c6"}}}]}, {"uuid": "14f5c982-a941-47eb-bbe3-5a71b7002ef0", "name": "load_p1rlv11399_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68a9eead-8197-4e82-a444-2a4544ec9ddb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "412f3c1c-8bd1-4f9a-8b78-ff10d0dc33af"}}}}, {"uuid": "1c93c64e-c366-4e8e-be51-80ed7c2dc1ab", "name": "a8d1b8f8-964b-4152-88cf-546f652122a5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7362273540893955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24527287728713068, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1f94519d-76c3-44f3-a4aa-a413daa3fc09", "name": "e9273d34-b533-405f-ab46-06cf3d1cbebd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1c93c64e-c366-4e8e-be51-80ed7c2dc1ab"}}}]}, {"uuid": "1a8b6d99-326a-4863-aafb-24b633c2de28", "name": "load_p1rlv11401_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a215d7dd-8081-4355-9c38-4fd3d2c859c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1f94519d-76c3-44f3-a4aa-a413daa3fc09"}}}}, {"uuid": "ed3a85b5-cc99-4309-803f-597146e69b7e", "name": "c2716fdb-6260-4b4e-99ee-3110b4c6e13b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7362273540893955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24527287728713068, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e6c2ba32-641e-40be-9196-97d7f0cdc413", "name": "e8b64d33-8988-4766-ac6b-b5cf996fed76", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ed3a85b5-cc99-4309-803f-597146e69b7e"}}}]}, {"uuid": "d2095444-e584-4f9e-96d6-7ee82d3f56cf", "name": "load_p1rlv11401_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a215d7dd-8081-4355-9c38-4fd3d2c859c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e6c2ba32-641e-40be-9196-97d7f0cdc413"}}}}, {"uuid": "19e6f0e2-d912-4218-9fd1-fd4d0924d194", "name": "217e84b9-c92a-4813-bda6-016f6ec450d4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.993849790823018, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8230403105677124, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "81000f39-1c4b-48e4-b9af-0b7e8a375a30", "name": "3e931a47-39f4-49a1-b7c1-d1a5dca4f47a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "19e6f0e2-d912-4218-9fd1-fd4d0924d194"}}}]}, {"uuid": "880c8a8f-8311-4eea-85c3-081629e5d51a", "name": "load_p1rlv11671_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "834a5733-5264-4adf-861a-25e494df3e37"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "81000f39-1c4b-48e4-b9af-0b7e8a375a30"}}}}, {"uuid": "fa41be16-4f77-4d8b-8d3c-5bded2c2b3d2", "name": "3a0c9a3d-d0d9-4cef-b356-9296bc4e6ebb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.993849790823018, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8230403105677124, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5de76861-367c-419e-9ebf-d23598dc70c8", "name": "c79e609b-1aa4-4707-894b-5b353a30e4b3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fa41be16-4f77-4d8b-8d3c-5bded2c2b3d2"}}}]}, {"uuid": "ffffb06b-53dd-40e2-88d0-c56f9b9119a7", "name": "load_p1rlv11671_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "834a5733-5264-4adf-861a-25e494df3e37"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5de76861-367c-419e-9ebf-d23598dc70c8"}}}}, {"uuid": "7b0aea3d-5a84-4c93-8187-72c99666a6e7", "name": "9ef80507-36c4-4ed5-a827-d4bab96aa770_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.207629741893862, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.47552489685620736, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cdaab1e9-9218-4f89-879c-17def2df400d", "name": "b090e00b-d7e5-485d-998b-bb3e5a4156b2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b0aea3d-5a84-4c93-8187-72c99666a6e7"}}}]}, {"uuid": "4280bfa9-be32-40fd-bdb0-2e913cfe06f7", "name": "load_p1rlv11674_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "45f2a901-e4f7-4055-a3e2-b60c61d5033e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cdaab1e9-9218-4f89-879c-17def2df400d"}}}}, {"uuid": "942399c1-c215-463d-ab01-2b5b49c33988", "name": "2ada6355-9751-4aa1-8e94-23629ffcbcea_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.207629741893862, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.47552489685620736, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "88679627-5a13-4b2f-9104-c1ab907ef8d2", "name": "7dc64782-55da-4ebf-9774-248dfaf2aeb3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "942399c1-c215-463d-ab01-2b5b49c33988"}}}]}, {"uuid": "3afad982-a47a-4bfd-b962-d5030608149a", "name": "load_p1rlv11674_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "45f2a901-e4f7-4055-a3e2-b60c61d5033e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "88679627-5a13-4b2f-9104-c1ab907ef8d2"}}}}, {"uuid": "7fdeae6b-bad2-4d38-a3eb-b1b886bb88b2", "name": "58c28d80-812f-4f45-b252-f3b925518e56_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.350180554065672, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.234423023465851, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "78047efa-5aae-4c22-bbfd-1e309fce9b3d", "name": "5014b4f3-eb2f-4d8a-b195-fedddd1a282a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7fdeae6b-bad2-4d38-a3eb-b1b886bb88b2"}}}]}, {"uuid": "e21bce72-76a7-41e5-bfdb-2fd16a75d549", "name": "load_p1rlv11677_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b2f121a-2202-43c0-8684-81913a5d6ea9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "78047efa-5aae-4c22-bbfd-1e309fce9b3d"}}}}, {"uuid": "3fb2b49c-5421-416a-81b8-ed45941c710b", "name": "010a5d40-5063-4cec-b10e-a8c6e97802f0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.350180554065672, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.234423023465851, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cbba316b-4388-493d-bebf-b65b224f77b1", "name": "9dc512e3-833a-4d0a-901e-d9d6f764a902", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3fb2b49c-5421-416a-81b8-ed45941c710b"}}}]}, {"uuid": "82bec9a8-854a-4931-b6be-6add2702d1a6", "name": "load_p1rlv11677_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b2f121a-2202-43c0-8684-81913a5d6ea9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cbba316b-4388-493d-bebf-b65b224f77b1"}}}}, {"uuid": "73a7b9d9-ecd8-46e9-8986-42f2efd7f8c6", "name": "84a7323c-c0fb-4d34-8f47-c23cb918fafe_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.646242553828346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.7481060562472628, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2a45bee3-8c33-4cbe-a582-6377ecc23b9f", "name": "84a7323c-c0fb-4d34-8f47-c23cb918fafe_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.646242553828346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.7481060562472628, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7b0b3590-6acf-417b-9bb2-452f23225443", "name": "84a7323c-c0fb-4d34-8f47-c23cb918fafe_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.646242553828346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.7481060562472628, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f34e4e1c-6c8f-4059-adc9-2b64ec93e326", "name": "f086a3d6-c467-4700-abc5-5d2277d44341", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "73a7b9d9-ecd8-46e9-8986-42f2efd7f8c6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2a45bee3-8c33-4cbe-a582-6377ecc23b9f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b0b3590-6acf-417b-9bb2-452f23225443"}}}]}, {"uuid": "199bfa85-465c-4650-8ef3-90f96b88b204", "name": "load_p1rlv11679", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4747e0f3-2a66-4e5a-8160-ac0aabe34489"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f34e4e1c-6c8f-4059-adc9-2b64ec93e326"}}}}, {"uuid": "0e0463d4-ce3e-4fc6-9932-5ad1716ba8a4", "name": "065c9709-49a5-4a99-969e-d1ab3384fb45_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5348201699646123, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21241824123648728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f04a5ba1-dccd-43ea-9d4c-422a4ef9bc8f", "name": "a950f1cc-c8ce-471b-b119-37def2974705", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0e0463d4-ce3e-4fc6-9932-5ad1716ba8a4"}}}]}, {"uuid": "eeae5cd3-47cb-420f-82eb-e82981fc3166", "name": "load_p1rlv11684_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02aef971-5f4a-4ca8-aa33-cce34517bd44"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f04a5ba1-dccd-43ea-9d4c-422a4ef9bc8f"}}}}, {"uuid": "c113a2d0-7a1a-4ef0-b68c-e48e85a1090f", "name": "54701ebb-2c42-4b9d-9413-2113bdd4b2d5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5348201699646123, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21241824123648728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "146aded8-811d-43e7-93c3-2ff6315ddb15", "name": "4fdd7731-7414-4d6a-b123-66bb72d3735f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c113a2d0-7a1a-4ef0-b68c-e48e85a1090f"}}}]}, {"uuid": "39427790-3cc9-4d35-b072-1b8584b28d52", "name": "load_p1rlv11684_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02aef971-5f4a-4ca8-aa33-cce34517bd44"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "146aded8-811d-43e7-93c3-2ff6315ddb15"}}}}, {"uuid": "0f0f3eff-f75b-412b-b376-fd15c18d9230", "name": "711648f9-ebb7-4f4e-b932-f24da15200e6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7134847388598258, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.27646838411203456, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2074fde9-c64d-43a4-9028-6b9f09dd0c72", "name": "910b07e4-fe64-4347-a582-ae11ab6afa54", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0f0f3eff-f75b-412b-b376-fd15c18d9230"}}}]}, {"uuid": "f74274b2-e40e-49ec-a06e-9124509405b4", "name": "load_p1rlv11686_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cda8e361-98b6-49bd-a3ff-30a036a3dc6f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2074fde9-c64d-43a4-9028-6b9f09dd0c72"}}}}, {"uuid": "5b421636-ffa4-4703-9f40-c5fa17a9ef1a", "name": "0009cc4f-de5f-4ad5-aa48-0ff3c85e7cb0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7134847388598258, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.27646838411203456, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a935d79-007f-4e78-9f82-58519fc58985", "name": "64531b1b-d21e-47e0-90b2-87975e64e9bc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b421636-ffa4-4703-9f40-c5fa17a9ef1a"}}}]}, {"uuid": "0128e4c0-7225-4072-81cb-76e07c494424", "name": "load_p1rlv11686_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cda8e361-98b6-49bd-a3ff-30a036a3dc6f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a935d79-007f-4e78-9f82-58519fc58985"}}}}, {"uuid": "bcaa9aa5-7611-4cab-8e97-f648f007f6ec", "name": "8ac0ffc9-1f1f-4e44-b05b-3c6c4e9f4bcf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.685213211371405, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7584354740780123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b6106aee-0e71-4823-9b54-b821dbe6e9e3", "name": "2518ab62-028f-406d-8805-cd8ff9e7c663", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bcaa9aa5-7611-4cab-8e97-f648f007f6ec"}}}]}, {"uuid": "2f03a659-6950-4b38-824c-fcab53770ada", "name": "load_p1rlv11779_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0ba1408-17da-4678-8b04-90c616c3fb48"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b6106aee-0e71-4823-9b54-b821dbe6e9e3"}}}}, {"uuid": "54d15814-1f86-46d8-ba4e-8005594b9e8c", "name": "673f5872-4f13-461c-8547-73d1563f4ca2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.685213211371405, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7584354740780123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "68e84740-bc6d-46b3-b5a1-de230ba2ba8c", "name": "d8fcf121-24ec-4589-af9b-16f85e167894", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "54d15814-1f86-46d8-ba4e-8005594b9e8c"}}}]}, {"uuid": "36b3f0e7-e125-444a-953f-0f418ce90d34", "name": "load_p1rlv11779_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0ba1408-17da-4678-8b04-90c616c3fb48"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "68e84740-bc6d-46b3-b5a1-de230ba2ba8c"}}}}, {"uuid": "2bc5ddc5-f9cf-4c31-a698-e45162a59f52", "name": "de86f7c4-960b-434d-a501-6e2a48c45b5e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8140781365796688, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5845737413475921, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f8b6903-d695-4864-8bd1-5d6ef43823d3", "name": "9f5d99d3-8bbb-4f4b-82b3-c6fa3a499604", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2bc5ddc5-f9cf-4c31-a698-e45162a59f52"}}}]}, {"uuid": "ae28e7f9-10c4-4478-beb9-3cda7def6e12", "name": "load_p1rlv11780_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e9a574d-9537-417a-a811-e22d84b8ea53"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f8b6903-d695-4864-8bd1-5d6ef43823d3"}}}}, {"uuid": "0bb832a9-296f-4ab9-b79f-c6729e9a95f1", "name": "b62bc94e-46b0-4893-b9d9-63b0d76a65c4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8140781365796688, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5845737413475921, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d6007af3-04d8-4d6b-98a0-75e82c07ad9e", "name": "aa693dc2-7f08-4d51-bd8d-957884a3cb4b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0bb832a9-296f-4ab9-b79f-c6729e9a95f1"}}}]}, {"uuid": "2b081bb3-2ae6-44e9-bff1-82782c105da7", "name": "load_p1rlv11780_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e9a574d-9537-417a-a811-e22d84b8ea53"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d6007af3-04d8-4d6b-98a0-75e82c07ad9e"}}}}, {"uuid": "384cf2bf-2e3f-496f-8c9f-7c60d688c039", "name": "8a16d511-aa5c-4d7e-8a2a-dc06a8786cf8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.511185229285174, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8722130080127372, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6a3dec04-d7d9-4d23-9487-257b4c3812db", "name": "49c94614-c682-4183-a3ee-47532aeabbd9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "384cf2bf-2e3f-496f-8c9f-7c60d688c039"}}}]}, {"uuid": "d9cfe7dd-04e6-4dcf-ab7f-2acbe28a3430", "name": "load_p1rlv11781_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28fd9f7c-0195-4529-a972-aa60eced47d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6a3dec04-d7d9-4d23-9487-257b4c3812db"}}}}, {"uuid": "d02a4dfd-0db0-4c84-a0d0-55acac4da244", "name": "f894fb6a-1944-4860-81b8-0d511b69b152_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.511185229285174, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8722130080127372, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "04f35fd9-0ef5-4f14-a6e3-cefc0476f467", "name": "65a6d6bc-d2e4-4d3c-87c0-3c49631c0586", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d02a4dfd-0db0-4c84-a0d0-55acac4da244"}}}]}, {"uuid": "784301f3-c814-4f30-a094-a5ad526eafc4", "name": "load_p1rlv11781_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28fd9f7c-0195-4529-a972-aa60eced47d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "04f35fd9-0ef5-4f14-a6e3-cefc0476f467"}}}}, {"uuid": "c29d78d2-6f86-4a75-8639-46b5737b9f3a", "name": "da9297a7-e14d-4032-80c3-bd916fb0f82e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9571742049653674, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.37384849940856246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c91df66f-cf2c-4308-9e5e-6ae3c4236103", "name": "598bffc5-e44d-4424-b327-473c6b33c699", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c29d78d2-6f86-4a75-8639-46b5737b9f3a"}}}]}, {"uuid": "d4d57c2d-e4fb-45e4-8ca1-5861e1d03e26", "name": "load_p1rlv11782_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "496fc854-bbf8-463b-b16c-12dd1b444cc6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c91df66f-cf2c-4308-9e5e-6ae3c4236103"}}}}, {"uuid": "59ec2523-a40e-4626-83a9-942fb8b00d3c", "name": "0175315c-636a-4bdf-8ec1-9ece9762cfd7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9571742049653674, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.37384849940856246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "55fe2d83-23b8-4e04-bb5f-c0c39fa59d22", "name": "7ffab4d1-ae5f-47c4-bc80-1b5ef215933d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "59ec2523-a40e-4626-83a9-942fb8b00d3c"}}}]}, {"uuid": "dc1725f4-043c-489e-ad6e-a489b6a3ddde", "name": "load_p1rlv11782_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "496fc854-bbf8-463b-b16c-12dd1b444cc6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "55fe2d83-23b8-4e04-bb5f-c0c39fa59d22"}}}}, {"uuid": "719f3565-2a90-447f-b37f-62c4575685a5", "name": "74b0364c-70f7-4cfa-9a50-696d19276a50_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6943701970081404, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21264462112520055, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "04a97427-3eb0-4dd5-8318-2b1618f2db99", "name": "25c4c1f0-dda3-4377-ab72-f6328c96ad2c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "719f3565-2a90-447f-b37f-62c4575685a5"}}}]}, {"uuid": "c0d0846d-b13d-4842-be91-f5890fae2efa", "name": "load_p1rlv11783_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3890375-c01d-44d2-93f9-8d9d60da8852"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "04a97427-3eb0-4dd5-8318-2b1618f2db99"}}}}, {"uuid": "a833347b-51ca-4335-a3b7-2815a8802252", "name": "715e0283-8919-4ab8-8785-bd42398faa71_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6943701970081404, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21264462112520055, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d4366736-a6a8-4466-bdda-dd0d4f71e800", "name": "c972beca-c3aa-48b8-9bb8-2e95b0231cd1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a833347b-51ca-4335-a3b7-2815a8802252"}}}]}, {"uuid": "7a0211f4-3574-4963-8c61-ef4aa454aab7", "name": "load_p1rlv11783_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3890375-c01d-44d2-93f9-8d9d60da8852"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d4366736-a6a8-4466-bdda-dd0d4f71e800"}}}}, {"uuid": "74aeab76-c309-4409-b010-a63870f4cc44", "name": "2bb9988e-44b9-4e7a-a6e6-1457f5fd33ec_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.991741378519742, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22993168819558238, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "70c39461-4170-4085-8dd6-3521bdb1cee8", "name": "f6e7cbfd-d137-4329-92ee-5b9518fb7227", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "74aeab76-c309-4409-b010-a63870f4cc44"}}}]}, {"uuid": "bbaa94b7-26a0-4490-b73f-3f48efcd8109", "name": "load_p1rlv11784_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b66df0bc-6159-42fa-bf49-b8ad17d0e6aa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "70c39461-4170-4085-8dd6-3521bdb1cee8"}}}}, {"uuid": "14682214-bd52-4703-aeee-3855f6362b25", "name": "b01eff19-3110-434c-8ce9-8d5f9e392f71_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.991741378519742, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22993168819558238, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4c696357-ac6d-45a4-962b-355e9c7383a4", "name": "419de2c8-9215-4618-8fc3-0beef31859c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "14682214-bd52-4703-aeee-3855f6362b25"}}}]}, {"uuid": "f229a1db-0bdf-43d2-865e-4cddd2b3dd8c", "name": "load_p1rlv11784_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b66df0bc-6159-42fa-bf49-b8ad17d0e6aa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4c696357-ac6d-45a4-962b-355e9c7383a4"}}}}, {"uuid": "81aa2444-620f-45cc-98de-960fa593c2a6", "name": "5f30cec8-7b02-4fd1-b591-a2178d76d175_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9304883858291884, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.26579705258029934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5b8b6400-52cf-4605-af6d-5c3539407e22", "name": "892222e6-9006-4e8c-b1aa-6f9b3a88f2ca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "81aa2444-620f-45cc-98de-960fa593c2a6"}}}]}, {"uuid": "67f8b117-f8aa-4709-9095-1e625b55aaea", "name": "load_p1rlv11785_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ed0eb774-fcc3-417f-a8a4-fbdb825cc106"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5b8b6400-52cf-4605-af6d-5c3539407e22"}}}}, {"uuid": "1a8a6352-2858-476d-b4ae-541f4571c5d7", "name": "7cc3f58f-d2dc-4bee-9e76-d93a317bd5c2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9304883858291884, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.26579705258029934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "96c26c44-bee9-4f3d-8e1d-05ca261685b3", "name": "3fa9c194-4aa5-456e-a3bb-6475f8f83efb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1a8a6352-2858-476d-b4ae-541f4571c5d7"}}}]}, {"uuid": "7097c4ee-e786-4b71-b2a3-dd97cf49206a", "name": "load_p1rlv11785_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ed0eb774-fcc3-417f-a8a4-fbdb825cc106"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "96c26c44-bee9-4f3d-8e1d-05ca261685b3"}}}}, {"uuid": "b645010e-a80c-4a8e-847c-83155db97703", "name": "48b0ad64-80f4-4225-8b12-69d1c1fce2b4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9049571169929809, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.186253723079565, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "634e1d2e-df5c-4213-ab8a-387c3beb319a", "name": "43db1fb5-a161-48cd-b379-8efe6752dab5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b645010e-a80c-4a8e-847c-83155db97703"}}}]}, {"uuid": "70aaccc7-152f-4181-a716-cb618ede64a9", "name": "load_p1rlv11786_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b15fc66-89d9-483b-9c9f-9b0f39a63b29"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "634e1d2e-df5c-4213-ab8a-387c3beb319a"}}}}, {"uuid": "a27cf930-a2b9-45cb-833a-29d62bb98417", "name": "843c52bb-2b47-41ee-b817-12e7df53e0e9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9049571169929809, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.186253723079565, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4d47c6dc-872d-406b-a442-3bc658bf26b7", "name": "d430dd13-01cb-4cda-9824-6fb09a44693f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a27cf930-a2b9-45cb-833a-29d62bb98417"}}}]}, {"uuid": "257419d1-b753-4d96-bdce-38e1a1cd8134", "name": "load_p1rlv11786_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b15fc66-89d9-483b-9c9f-9b0f39a63b29"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4d47c6dc-872d-406b-a442-3bc658bf26b7"}}}}, {"uuid": "b05a753d-3db7-48b3-b47a-249c98ff3be1", "name": "a4b00cd0-fd5a-4f22-9a52-ed3053b4ee85_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.074192704000552, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.129078804753558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c988968-65a0-4532-a19d-556a07293824", "name": "44cf0c3d-0316-4a19-8733-0a867704b781", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b05a753d-3db7-48b3-b47a-249c98ff3be1"}}}]}, {"uuid": "e253f6fb-990c-4d8b-8948-9a3229cac708", "name": "load_p1rlv12028_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1dfd848-b639-41b5-ad95-2c03a51bd36b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c988968-65a0-4532-a19d-556a07293824"}}}}, {"uuid": "203f3b4c-a1b7-4d7d-8dde-44bba643968d", "name": "a49857dd-c662-47fa-b3d3-1bc2676ae6c5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.074192704000552, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.129078804753558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "07a841f3-9e9e-435e-8921-90257903027f", "name": "5e806831-a196-41a9-9872-c316842d0c89", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "203f3b4c-a1b7-4d7d-8dde-44bba643968d"}}}]}, {"uuid": "f55cbd96-3d00-4c50-9b1e-7949b1ccf7fa", "name": "load_p1rlv12028_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1dfd848-b639-41b5-ad95-2c03a51bd36b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "07a841f3-9e9e-435e-8921-90257903027f"}}}}, {"uuid": "552e95b7-8899-4680-b787-bd09d88fcbad", "name": "d624f5a9-8df5-49d9-8aab-f0ab2829963b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9920550244580673, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.016709072862991, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4a17a3d5-f916-40a8-9a3c-a75fabf7c4b9", "name": "04652eab-da1b-44bb-b119-da71f87b7c49", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "552e95b7-8899-4680-b787-bd09d88fcbad"}}}]}, {"uuid": "15f6d0d3-47f6-405d-860f-4c1f270e1b38", "name": "load_p1rlv12157_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc4d79bb-8ba3-4146-9d50-16db48ffec22"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4a17a3d5-f916-40a8-9a3c-a75fabf7c4b9"}}}}, {"uuid": "616909e4-20b5-4c69-8ff7-6e76d1373619", "name": "9a778301-544c-4279-8090-78f38718cff6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9920550244580673, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.016709072862991, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a0eda67-fcf7-4f79-9913-20f1f19267d3", "name": "3797bb29-31a1-4c97-b879-c67117445909", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "616909e4-20b5-4c69-8ff7-6e76d1373619"}}}]}, {"uuid": "7cf4078b-8cea-45d9-b31f-65e4f30ac480", "name": "load_p1rlv12157_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc4d79bb-8ba3-4146-9d50-16db48ffec22"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0a0eda67-fcf7-4f79-9913-20f1f19267d3"}}}}, {"uuid": "93349afb-bb23-4e5a-96c4-865535c7fce2", "name": "387701da-b42d-4acc-9a36-d349f1506115_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4651344294517608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7736313908316925, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bbe48d7c-1401-44fa-9c7f-809f2a444159", "name": "a44c1150-9305-4d3e-b8c4-f08012ed1336", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "93349afb-bb23-4e5a-96c4-865535c7fce2"}}}]}, {"uuid": "90927d12-f7db-4258-9750-300ae537663f", "name": "load_p1rlv12214_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df9d9de2-6929-48a4-a390-c0e2f129b374"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bbe48d7c-1401-44fa-9c7f-809f2a444159"}}}}, {"uuid": "940f19a6-726f-4ae7-ab9c-62ed4a687ede", "name": "c22de480-94ab-4386-8777-6352bb23c4a9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4651344294517608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7736313908316925, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a359518f-9c6f-44f3-bba7-02c74e67773b", "name": "7cafa9c5-8e2b-4908-8492-7901adf43b91", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "940f19a6-726f-4ae7-ab9c-62ed4a687ede"}}}]}, {"uuid": "be825c77-6ca2-4d5d-99a4-53a5543c2ea2", "name": "load_p1rlv12214_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df9d9de2-6929-48a4-a390-c0e2f129b374"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a359518f-9c6f-44f3-bba7-02c74e67773b"}}}}, {"uuid": "8000ba09-9e9b-47e7-9248-e5cd7eb89b1f", "name": "9390d150-0a92-45a1-a68b-a305c8617dcd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.84153235443771, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.447226409705929, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7c1a452d-e2b6-417d-a4f3-f8b3e9b59441", "name": "413ffaf3-a662-40e4-a1cb-4187df3cca66", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8000ba09-9e9b-47e7-9248-e5cd7eb89b1f"}}}]}, {"uuid": "a5fee8da-8631-4a13-a56e-4b3ac2d97499", "name": "load_p1rlv12217_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4d26673-c304-41de-8b5b-149552601ba4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7c1a452d-e2b6-417d-a4f3-f8b3e9b59441"}}}}, {"uuid": "c90df63f-8a49-4713-98f6-06f17ab46792", "name": "ea12689a-7116-40d9-a027-ca1635ed75dc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.84153235443771, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.447226409705929, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0e05b6fc-4c45-4fd7-9c22-8340c45a3606", "name": "8b56535d-9f54-4ad3-9c6a-791882e318e3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c90df63f-8a49-4713-98f6-06f17ab46792"}}}]}, {"uuid": "e485265f-9f8d-4245-ad17-5d4e5e1c3807", "name": "load_p1rlv12217_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4d26673-c304-41de-8b5b-149552601ba4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0e05b6fc-4c45-4fd7-9c22-8340c45a3606"}}}}, {"uuid": "eb75ab7d-98c0-4140-aef1-328cd7e4116d", "name": "0760525e-b253-41d0-b2cd-687cd73d9c1e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.799969889792979, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7055837837850989, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "042dfb11-6154-4b13-9408-0cd2ab142536", "name": "ab587f0c-6725-497c-ad32-aa49117ef7a8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eb75ab7d-98c0-4140-aef1-328cd7e4116d"}}}]}, {"uuid": "bc041c92-4b53-4a56-a2fb-e457b789cd43", "name": "load_p1rlv12222_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cee79fe8-f140-4be9-aa6b-d56e37fb6857"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "042dfb11-6154-4b13-9408-0cd2ab142536"}}}}, {"uuid": "b0d438e5-c608-402c-b4f6-9f25bd01a42e", "name": "c6b2d280-584e-43d4-a753-6be9b18ab723_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.799969889792979, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7055837837850989, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e7a368d6-2f67-4798-acb9-d269a780643e", "name": "d8f0ae6e-e5fc-404e-94db-798335a77be1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b0d438e5-c608-402c-b4f6-9f25bd01a42e"}}}]}, {"uuid": "79f820d2-8c76-454c-8b6f-c034813dfa94", "name": "load_p1rlv12222_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cee79fe8-f140-4be9-aa6b-d56e37fb6857"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e7a368d6-2f67-4798-acb9-d269a780643e"}}}}, {"uuid": "8a292298-d87c-40ba-99b3-0870bd235430", "name": "4aff0686-b279-4769-8696-0f117f3f32ab_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0087998942532215, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8303357169547151, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7a23e6bd-80a6-48f6-9573-655b5666a234", "name": "4fab9f05-0766-47da-9a87-043511271416", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a292298-d87c-40ba-99b3-0870bd235430"}}}]}, {"uuid": "1711e0a2-ee71-472d-9af5-5fa31beeaac0", "name": "load_p1rlv12225_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8e1f797-9417-447c-8a08-cf00a462ef14"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7a23e6bd-80a6-48f6-9573-655b5666a234"}}}}, {"uuid": "4f1b5334-965c-4525-a322-5fe06c498bb7", "name": "ea7d87bf-96a1-4601-b23b-bda186f96246_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0087998942532215, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8303357169547151, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bdaf1aa2-43b3-47cd-9d94-8e7d2bb7b510", "name": "398b200b-5935-44e0-ab49-e5e703cf9715", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4f1b5334-965c-4525-a322-5fe06c498bb7"}}}]}, {"uuid": "4b1b40e1-5681-448e-a18b-39482f3ba885", "name": "load_p1rlv12225_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8e1f797-9417-447c-8a08-cf00a462ef14"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bdaf1aa2-43b3-47cd-9d94-8e7d2bb7b510"}}}}, {"uuid": "b8deb33a-f898-4d69-97ce-bf091c2f724e", "name": "384f4eb4-eab8-4690-886d-9cf71c4744d7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "55635006-f0f4-4f03-80e7-0beecf5255f6", "name": "6d2bbb29-4ca4-4dd4-8fef-eb4cb60eb63e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b8deb33a-f898-4d69-97ce-bf091c2f724e"}}}]}, {"uuid": "d0db2faa-7719-4473-9f95-ecdc785a82de", "name": "load_p1rlv12538_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b42c2471-9114-4042-980e-dd226ad024a3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "55635006-f0f4-4f03-80e7-0beecf5255f6"}}}}, {"uuid": "38ca2981-1679-4764-a838-f05b5da5b7b2", "name": "e4d803a9-4542-4d57-88bc-b050a947ef29_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b0938b16-1cb9-4e1a-8d43-6ef059d68218", "name": "5ecac895-5d8e-4356-a367-3fc11dfe5b1a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "38ca2981-1679-4764-a838-f05b5da5b7b2"}}}]}, {"uuid": "4bdaf9b4-ca85-4214-b3d0-fab6ecc04fa0", "name": "load_p1rlv12538_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b42c2471-9114-4042-980e-dd226ad024a3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b0938b16-1cb9-4e1a-8d43-6ef059d68218"}}}}, {"uuid": "7af170d2-f91e-49a1-b46a-9d1b3fdac5c2", "name": "fbc4c379-57b8-4715-be21-42a6b2e361f4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.019297318507635, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.02246974709606756, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1fac8763-3ee1-43e7-bcf3-41617c46e963", "name": "f8e332fc-ec82-416e-b3d6-8b14e1a23653", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7af170d2-f91e-49a1-b46a-9d1b3fdac5c2"}}}]}, {"uuid": "28b67365-ae57-4a50-9c3f-0d620c71a219", "name": "load_p1rlv12552_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c42d772-e2a8-45d4-9cf2-2edd7a567b35"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1fac8763-3ee1-43e7-bcf3-41617c46e963"}}}}, {"uuid": "a378f8a4-8021-485f-860d-aa2a2032d46d", "name": "c6a7766f-684b-4d18-8619-a3e8a6fb87ce_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.019297318507635, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.02246974709606756, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f2ffd1ed-8ac4-4d30-bf95-beddb8475dfb", "name": "87f2a343-b853-4cce-827f-1d2dbc76cb67", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a378f8a4-8021-485f-860d-aa2a2032d46d"}}}]}, {"uuid": "9667ccde-7679-492a-80de-2ab510342e72", "name": "load_p1rlv12552_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c42d772-e2a8-45d4-9cf2-2edd7a567b35"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f2ffd1ed-8ac4-4d30-bf95-beddb8475dfb"}}}}, {"uuid": "31838ae9-5bec-4bfe-83d3-5a758bb306f4", "name": "8d2dfc6e-c33b-4d6c-be06-4b5f020bb41a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2219087879829873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3595087789107823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "13e11be6-6fef-46bd-a8ff-df8d3810df63", "name": "7e84ed5f-2b1e-4383-92e9-5ec8f0524021", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "31838ae9-5bec-4bfe-83d3-5a758bb306f4"}}}]}, {"uuid": "5dda57ed-b319-494c-9d87-380540189d12", "name": "load_p1rlv12553_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a29aec49-62a4-41ec-a67c-a84470a23f7b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "13e11be6-6fef-46bd-a8ff-df8d3810df63"}}}}, {"uuid": "10f2e55a-4148-43f9-a8e9-4720e944f9db", "name": "f9bc0bd6-0fa0-4d6b-aa84-287b48754b10_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2219087879829873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3595087789107823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1efcf0f6-12e0-457b-994d-41864b64821c", "name": "f4aef277-ad74-480c-8e1d-45906fd74985", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "10f2e55a-4148-43f9-a8e9-4720e944f9db"}}}]}, {"uuid": "7ce39498-91c4-4f3a-bdee-ca51755f3d8f", "name": "load_p1rlv12553_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a29aec49-62a4-41ec-a67c-a84470a23f7b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1efcf0f6-12e0-457b-994d-41864b64821c"}}}}, {"uuid": "e17e5f3b-1fa7-4e02-83f1-70a065023638", "name": "0500e3cd-6e22-4a48-bd68-2da9bc824009_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "77c2f716-98c7-4441-bb4a-bb0c0f6784c8", "name": "0500e3cd-6e22-4a48-bd68-2da9bc824009_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bf053ec5-8ce2-4779-9c8a-07b6844e1fbc", "name": "0500e3cd-6e22-4a48-bd68-2da9bc824009_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c5a6b4d5-ace0-436b-827a-428dd72a82ca", "name": "a105b17e-37ea-4df0-8c38-0552a55db7ce", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e17e5f3b-1fa7-4e02-83f1-70a065023638"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "77c2f716-98c7-4441-bb4a-bb0c0f6784c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bf053ec5-8ce2-4779-9c8a-07b6844e1fbc"}}}]}, {"uuid": "c6d2bf5b-f470-40ce-b8e4-96cfd0e92a44", "name": "load_p1rlv12555", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc71e486-4a44-466d-bc57-85591b269949"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c5a6b4d5-ace0-436b-827a-428dd72a82ca"}}}}, {"uuid": "1cbd663f-6a1c-4ea8-bded-0d70d902cae6", "name": "f1be257d-cb3a-4fc0-8586-41749bc934a6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.885552109924766, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6041260127278384, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ffec3052-3abb-4450-8007-84eb1a135bdd", "name": "4dc44239-3a7f-4899-a30b-0117e115c1b5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1cbd663f-6a1c-4ea8-bded-0d70d902cae6"}}}]}, {"uuid": "7db8574c-df37-49fc-8c22-8dbf718a039b", "name": "load_p1rlv12557_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fe4d6ae-cca5-476c-981a-a1dcd27b1e84"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ffec3052-3abb-4450-8007-84eb1a135bdd"}}}}, {"uuid": "b0bf587d-8b6c-44a5-a550-676ae3aeb192", "name": "f4b5e26d-8b61-4ee2-8ecf-038f2fb4bca0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.885552109924766, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6041260127278384, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e6120965-3163-44d8-8795-e883b0e34afe", "name": "d3b636f0-790f-4e54-9421-c06065a70246", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b0bf587d-8b6c-44a5-a550-676ae3aeb192"}}}]}, {"uuid": "2ce60fb7-a0a5-4497-b6c9-5145427b22f3", "name": "load_p1rlv12557_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fe4d6ae-cca5-476c-981a-a1dcd27b1e84"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e6120965-3163-44d8-8795-e883b0e34afe"}}}}, {"uuid": "fceb259d-954e-4c0d-a150-78ac533baca1", "name": "e0c5a270-abfa-4883-8baf-ed86fb59ffb0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.408318732620361, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.41814988562464883, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "94430f1e-1b47-4835-9d87-a26d30ac25f4", "name": "5d608f62-d235-48f6-905d-fb4ad378a38e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fceb259d-954e-4c0d-a150-78ac533baca1"}}}]}, {"uuid": "b52d40e1-7dd4-4d66-932d-26e4adbf6420", "name": "load_p1rlv12558_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a427f20-861a-4616-9443-265beaeccca3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "94430f1e-1b47-4835-9d87-a26d30ac25f4"}}}}, {"uuid": "b67cc3a7-efc2-4b73-8760-243e73ec84e9", "name": "a519c9c5-243d-4164-8d71-d9ebf568709c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.408318732620361, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.41814988562464883, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7dad946a-64e6-471e-9d5a-f5c2b56b4453", "name": "28666f42-b2e8-4084-a71f-177b3f358f9a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b67cc3a7-efc2-4b73-8760-243e73ec84e9"}}}]}, {"uuid": "32210c0c-5a99-44d3-89da-dcd3a4957933", "name": "load_p1rlv12558_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a427f20-861a-4616-9443-265beaeccca3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7dad946a-64e6-471e-9d5a-f5c2b56b4453"}}}}, {"uuid": "a7aeb239-b12f-43d8-9254-ceaa8ce5e63e", "name": "7d4a04f8-e89e-4c6a-baff-658b68f7e66d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4ef0e256-0104-4670-ab8e-66c781b92406", "name": "dae4cac6-0ccf-403a-8a0b-4866a8108bc2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a7aeb239-b12f-43d8-9254-ceaa8ce5e63e"}}}]}, {"uuid": "01613cf8-4c62-4ab0-aaf7-05cb942bf041", "name": "load_p1rlv12559_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a47101-b6df-473e-9c7b-96e076c17931"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4ef0e256-0104-4670-ab8e-66c781b92406"}}}}, {"uuid": "512b1fd5-c86c-41ad-a872-0d065db783c7", "name": "65a5f5f0-0ae7-4772-9834-824f5cd68277_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ac9edb43-7944-49af-972a-36bc7f104596", "name": "450e2d61-d419-4788-9fe1-76e179c9155e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "512b1fd5-c86c-41ad-a872-0d065db783c7"}}}]}, {"uuid": "f31a4f65-f744-4d57-848a-782d2ce69a80", "name": "load_p1rlv12559_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a47101-b6df-473e-9c7b-96e076c17931"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ac9edb43-7944-49af-972a-36bc7f104596"}}}}, {"uuid": "8d05d7db-5906-45a2-b1df-57fb6360a6b9", "name": "f2f96b59-653b-4115-b388-497ff52e86b5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4cff9875-7386-458a-9b64-80156936c140", "name": "5af06e9b-23e0-4f6e-a121-7535fd7f88ca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8d05d7db-5906-45a2-b1df-57fb6360a6b9"}}}]}, {"uuid": "c907954e-7703-4c1f-9a10-7dfbbb090930", "name": "load_p1rlv12562_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b0417d3-820d-4daa-aec5-3dcf34e40e00"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4cff9875-7386-458a-9b64-80156936c140"}}}}, {"uuid": "31402909-c881-44f6-9600-4af29e18b80c", "name": "258b099f-96f3-42c9-97ce-6c940296fb86_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d734fea1-2101-4015-8765-d044ecca754e", "name": "718893c7-d6f5-46c0-89e9-ddff0d94b2ef", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "31402909-c881-44f6-9600-4af29e18b80c"}}}]}, {"uuid": "7d67f5e1-9d72-499d-a95a-be3277402376", "name": "load_p1rlv12562_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b0417d3-820d-4daa-aec5-3dcf34e40e00"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d734fea1-2101-4015-8765-d044ecca754e"}}}}, {"uuid": "57030d1d-0515-409b-aa4a-387c467d26ac", "name": "1a257e80-dfde-40c4-aa55-d37da79da837_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "350a7ad6-f872-4619-ae5f-cfd457befd45", "name": "1a257e80-dfde-40c4-aa55-d37da79da837_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "81199978-dcd1-47b2-8456-f39100ae2842", "name": "1a257e80-dfde-40c4-aa55-d37da79da837_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "320af1ec-76c0-4573-9c87-c3be63bcca88", "name": "6dade334-e8c5-4f6d-8279-8cd008e9a44d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "57030d1d-0515-409b-aa4a-387c467d26ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "350a7ad6-f872-4619-ae5f-cfd457befd45"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "81199978-dcd1-47b2-8456-f39100ae2842"}}}]}, {"uuid": "17b19812-d10c-4cc3-8e0b-b93942f5974c", "name": "load_p1rlv12567", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29476f95-f85b-4843-a847-3d9d99da3b74"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "320af1ec-76c0-4573-9c87-c3be63bcca88"}}}}, {"uuid": "f44bfd34-ad29-4174-a161-329b1224269d", "name": "36a08b46-936f-47a7-a34b-83acf6359197_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1813646779377422, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20173832232537287, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b8f01aa2-00fd-4dcd-95d3-ee92c7dc38da", "name": "ce99f5ba-9e66-476d-9b98-d5895b6afb7a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f44bfd34-ad29-4174-a161-329b1224269d"}}}]}, {"uuid": "8c1c77d8-e76c-4eda-bff9-22efc95cca94", "name": "load_p1rlv12936_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "019e419c-9f88-455a-bf48-b89531ed9e51"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b8f01aa2-00fd-4dcd-95d3-ee92c7dc38da"}}}}, {"uuid": "7f3d1ad9-9edb-4501-95e7-11dd23a50986", "name": "f8e1f177-5d01-4890-bfdc-99a3c60f7353_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1813646779377422, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20173832232537287, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "59dc5206-5cf4-4a62-8f4a-564ccced3760", "name": "7e6fccaf-608c-460d-b620-86aa98026b84", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7f3d1ad9-9edb-4501-95e7-11dd23a50986"}}}]}, {"uuid": "64ecfe23-c977-4298-9dc8-22e8d727ecc3", "name": "load_p1rlv12936_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "019e419c-9f88-455a-bf48-b89531ed9e51"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "59dc5206-5cf4-4a62-8f4a-564ccced3760"}}}}, {"uuid": "afa36572-c7ae-4d30-a2cf-34a94041a92f", "name": "95dd7527-7120-47c6-9afa-d40a630910f0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.674261199298095, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1525334183561808, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c66704e3-e385-47ce-b33a-e2c4375ef14e", "name": "7b00e015-39f0-4fc3-86ed-c4037ef252ea", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "afa36572-c7ae-4d30-a2cf-34a94041a92f"}}}]}, {"uuid": "a215654e-7a13-4de0-8afb-2f584ea13270", "name": "load_p1rlv12959_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8418804f-aad5-49df-9916-f427da5089c1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c66704e3-e385-47ce-b33a-e2c4375ef14e"}}}}, {"uuid": "ec3f59ba-2ece-4e43-8236-8c9de91b7627", "name": "5341f2d5-824e-4ce2-a368-edbf3ae10d37_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.674261199298095, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1525334183561808, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5dfda74d-6533-41b2-b54f-7101f1bd6c06", "name": "63791f0a-1239-4534-a7b3-c82111e806d7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ec3f59ba-2ece-4e43-8236-8c9de91b7627"}}}]}, {"uuid": "a9e2e550-8519-457a-9432-96ca8f3494ab", "name": "load_p1rlv12959_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8418804f-aad5-49df-9916-f427da5089c1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5dfda74d-6533-41b2-b54f-7101f1bd6c06"}}}}, {"uuid": "6bafed9c-a79a-43e6-a2a6-6262cbf57402", "name": "6465f966-6ad2-4637-b178-c99221f13579_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.622949952431687, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7401570066486144, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aa680a67-4712-49b6-a6ef-d2abb1acc56c", "name": "c0e0b38a-4d53-4faf-bc78-726feff62d84", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6bafed9c-a79a-43e6-a2a6-6262cbf57402"}}}]}, {"uuid": "a267a065-bc37-434d-b77a-bd9be5993b1e", "name": "load_p1rlv12971_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be845651-8e1c-4b6d-8633-fcbdfb1fd5d4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aa680a67-4712-49b6-a6ef-d2abb1acc56c"}}}}, {"uuid": "d9161e28-a0e8-4632-ae36-7b0369feafe5", "name": "ecbbdcd3-87d4-4093-8c08-7131f570fb59_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.622949952431687, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7401570066486144, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9836cc02-f8d9-4b59-aaeb-a80e647f8b53", "name": "5183ea73-8c25-4849-b8c8-ac8d8262be00", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d9161e28-a0e8-4632-ae36-7b0369feafe5"}}}]}, {"uuid": "aa3223c1-16c1-4b3f-99e7-4134ca4d6bf0", "name": "load_p1rlv12971_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be845651-8e1c-4b6d-8633-fcbdfb1fd5d4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9836cc02-f8d9-4b59-aaeb-a80e647f8b53"}}}}, {"uuid": "bf2243f3-2f82-411a-a167-14dd3432096e", "name": "0e011f34-06de-4749-9462-166fa6b5bab8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.629144238694082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9654448182756213, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0e6b89e2-09ac-43e4-9fdf-5d1f0467c088", "name": "6d835633-768b-4507-aef7-efebcacfcf21", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bf2243f3-2f82-411a-a167-14dd3432096e"}}}]}, {"uuid": "ef085e54-6201-46d3-8f05-3179724d75da", "name": "load_p1rlv13043_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3072c6c-3a40-4e49-bd00-febc8268b135"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0e6b89e2-09ac-43e4-9fdf-5d1f0467c088"}}}}, {"uuid": "048c2b39-a731-4873-a791-7b25cf4be610", "name": "da303c9d-b1f7-4042-8a61-3318d0388810_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.629144238694082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9654448182756213, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "68485ccc-34ca-4e0d-b041-cf3abda83f2c", "name": "9503fa22-df99-4b16-9624-ba5058855d48", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "048c2b39-a731-4873-a791-7b25cf4be610"}}}]}, {"uuid": "cf1311b1-6044-4a3b-b741-8eba3f6a730f", "name": "load_p1rlv13043_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3072c6c-3a40-4e49-bd00-febc8268b135"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "68485ccc-34ca-4e0d-b041-cf3abda83f2c"}}}}, {"uuid": "29ea63e7-0679-4c22-8880-178658313e08", "name": "b0f23629-383c-4a33-8600-91e1c7d72d0b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.67656735172194, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8569955192100605, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a9952cc1-e7a5-411b-bc2b-9b562df4ea90", "name": "2018957d-e361-4656-a49e-7af6f7dd0ec2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "29ea63e7-0679-4c22-8880-178658313e08"}}}]}, {"uuid": "1ecebcd9-1364-4d70-ad28-909bb5b9d8fa", "name": "load_p1rlv13044_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa31c772-8460-4624-a123-64b87ca8d332"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a9952cc1-e7a5-411b-bc2b-9b562df4ea90"}}}}, {"uuid": "72973c4b-1480-4f11-b02c-02b2e34a71c3", "name": "adebbaae-4278-4f65-999f-fd3d7c4d898c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.67656735172194, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8569955192100605, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b55a038b-402f-4d21-8478-cd30f0dffba0", "name": "5b690348-d90e-445d-8fed-7350db417d1e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72973c4b-1480-4f11-b02c-02b2e34a71c3"}}}]}, {"uuid": "abb52718-5636-4abc-9e4b-b1ad17398d48", "name": "load_p1rlv13044_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa31c772-8460-4624-a123-64b87ca8d332"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b55a038b-402f-4d21-8478-cd30f0dffba0"}}}}, {"uuid": "3627100b-bd13-4957-bf7f-5b3dcb399273", "name": "2f7e63ee-606e-4006-8054-fa280fed04a2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.927062407458527, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.5614641711041375, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9696f3af-6d44-4089-8061-b37461d4c4bf", "name": "dcca069b-2167-4bef-9609-3a4a5e037504", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3627100b-bd13-4957-bf7f-5b3dcb399273"}}}]}, {"uuid": "beb721c2-d839-4335-bb0b-504d29a38675", "name": "load_p1rlv13045_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6070414d-09e7-48a7-aec0-c105cc0f1a93"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9696f3af-6d44-4089-8061-b37461d4c4bf"}}}}, {"uuid": "23f1d753-acb9-4529-8473-9d9b923aae89", "name": "838a49c5-8699-4ad8-bef6-e7c55e73e980_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.927062407458527, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.5614641711041375, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9e38c316-0bf1-4c33-b03d-6c2bf7a7b6f4", "name": "8496860e-e0bc-4f29-904a-b4ae24142a88", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "23f1d753-acb9-4529-8473-9d9b923aae89"}}}]}, {"uuid": "39d37fbc-2cb3-45bc-8cf5-cd01fbc253ab", "name": "load_p1rlv13045_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6070414d-09e7-48a7-aec0-c105cc0f1a93"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9e38c316-0bf1-4c33-b03d-6c2bf7a7b6f4"}}}}, {"uuid": "3d8a2220-4e4f-4e81-9717-bb8186a3a84a", "name": "aaf7daa9-44e0-4720-816a-bd6211d51e77_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 15.279136617573831, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5014115237228067, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8fed5cf1-3790-4d6a-abea-a0cdedfcbf66", "name": "86e517e9-c448-4f71-a223-b4a9e03e56ca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3d8a2220-4e4f-4e81-9717-bb8186a3a84a"}}}]}, {"uuid": "d201c1a8-8405-407a-b693-d3e6ecbdfc3b", "name": "load_p1rlv13046_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5edc15fb-49d5-4052-8fad-4979578f6ed1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8fed5cf1-3790-4d6a-abea-a0cdedfcbf66"}}}}, {"uuid": "9693a4ba-33c3-4686-95d8-bd54caac41d7", "name": "192aec90-8be0-407e-8eb1-02d103b8aa8f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 15.279136617573831, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5014115237228067, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6101ba57-b6a3-4b6f-96e4-155b9aaec470", "name": "fa37179a-b466-4601-80e7-601e4e1ea5e6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9693a4ba-33c3-4686-95d8-bd54caac41d7"}}}]}, {"uuid": "c0555aca-c68c-4f8e-9f96-4d02f0aa6ac2", "name": "load_p1rlv13046_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5edc15fb-49d5-4052-8fad-4979578f6ed1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6101ba57-b6a3-4b6f-96e4-155b9aaec470"}}}}, {"uuid": "e4bb654e-d037-44c7-93fb-136954260713", "name": "aedd0946-c9f5-4c4e-9a2d-a162cffd94db_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3374419606114465, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8276898777002473, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "336d306b-9868-4071-b9ad-f2f0b5a68ee8", "name": "bf70eb87-479c-41be-acc2-1f40468a8d77", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e4bb654e-d037-44c7-93fb-136954260713"}}}]}, {"uuid": "a8845610-255f-4497-9140-7e0b22d0ea41", "name": "load_p1rlv13047_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4209bdad-276f-4e07-93e0-78b162ce95cf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "336d306b-9868-4071-b9ad-f2f0b5a68ee8"}}}}, {"uuid": "0e5dc84b-05ee-499d-b21a-da930b8ff0e7", "name": "0f30c492-a1c2-433d-932c-4fadbc3cda54_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3374419606114465, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8276898777002473, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fce9ecb2-402a-4b36-b60f-4380bc572ff2", "name": "97aad36b-aaba-4ba4-8b0f-69233cde3781", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0e5dc84b-05ee-499d-b21a-da930b8ff0e7"}}}]}, {"uuid": "ea5f208e-4405-479a-9249-fdd564e27ac7", "name": "load_p1rlv13047_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4209bdad-276f-4e07-93e0-78b162ce95cf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fce9ecb2-402a-4b36-b60f-4380bc572ff2"}}}}, {"uuid": "a2344f4d-580f-4d1f-8ca7-96074f3a11ca", "name": "ece2f7cf-fbf5-46d5-89e6-03413649b91b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3862445486686554, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0100117110086289, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2ab11757-34f2-4b89-b71a-6fdd1a84a1db", "name": "c0c1eaed-9da8-478f-a901-91ac11e47dd5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a2344f4d-580f-4d1f-8ca7-96074f3a11ca"}}}]}, {"uuid": "da3b6c00-95ce-4543-b2b6-ad5d48e8ed50", "name": "load_p1rlv13048_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "569078be-37c2-4c05-8455-91945eb7fdb9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2ab11757-34f2-4b89-b71a-6fdd1a84a1db"}}}}, {"uuid": "6ccf68b4-da02-4d62-aef9-3c67796369ee", "name": "216328c0-676a-4590-9934-5ddf303cf7d0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3862445486686554, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0100117110086289, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6c2cb862-2147-4b66-9321-30946bf3fddf", "name": "c93767ca-1ca8-472b-9e64-148c1794dace", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6ccf68b4-da02-4d62-aef9-3c67796369ee"}}}]}, {"uuid": "6fccad50-53ea-47b2-b9a4-c004ab2e0953", "name": "load_p1rlv13048_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "569078be-37c2-4c05-8455-91945eb7fdb9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6c2cb862-2147-4b66-9321-30946bf3fddf"}}}}, {"uuid": "88a28a37-de8a-40f3-85a8-ecf02873796a", "name": "8e5e686d-f46a-4930-adcf-16b20d576e59_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.734495706390117, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.8488351310797768, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "02143f59-781d-4f3c-ae65-f5cdf7219e27", "name": "a05253a1-6c79-4fe6-8718-0385e58be912", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "88a28a37-de8a-40f3-85a8-ecf02873796a"}}}]}, {"uuid": "f24deddc-0423-4117-9703-7a99a11e928c", "name": "load_p1rlv13049_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ed85192-4c5a-4c15-ba21-1ba883b03ddd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "02143f59-781d-4f3c-ae65-f5cdf7219e27"}}}}, {"uuid": "a1c08b21-8534-4b31-8cb2-a5d67b33899e", "name": "a63d29ec-7a7d-4e93-841b-a67584b88102_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.734495706390117, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.8488351310797768, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "620b6660-d420-44fc-a878-b0ce12065187", "name": "2326f173-a2c2-4284-84a3-088d473aad62", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a1c08b21-8534-4b31-8cb2-a5d67b33899e"}}}]}, {"uuid": "216972e7-f384-4784-97d7-16866891173d", "name": "load_p1rlv13049_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ed85192-4c5a-4c15-ba21-1ba883b03ddd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "620b6660-d420-44fc-a878-b0ce12065187"}}}}, {"uuid": "5330a24c-1c74-4447-91f5-72636276f9cc", "name": "7c121eb7-6fec-4992-bc39-b0896d5a6423_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 23.2179949774968, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.953694721257675, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6aa3263e-c151-4899-9e82-4a851d6b2b6d", "name": "7c121eb7-6fec-4992-bc39-b0896d5a6423_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 23.2179949774968, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.953694721257675, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c69ddaa1-e2dd-411d-9010-ab6cd872259d", "name": "7c121eb7-6fec-4992-bc39-b0896d5a6423_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 23.2179949774968, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.953694721257675, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "54f818ce-e227-429b-81c2-73c52d992eb5", "name": "0f41eb01-df7d-4d64-b994-d868d16dd02d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5330a24c-1c74-4447-91f5-72636276f9cc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6aa3263e-c151-4899-9e82-4a851d6b2b6d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c69ddaa1-e2dd-411d-9010-ab6cd872259d"}}}]}, {"uuid": "82e9cc65-bb9f-47af-8448-b3675c52f170", "name": "load_p1rlv13050", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "051eba03-4728-4626-8add-5410b5326dc7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "54f818ce-e227-429b-81c2-73c52d992eb5"}}}}, {"uuid": "3c5de08d-4489-4eff-9d3a-df139e6261fa", "name": "b6c5b2c4-f466-45a3-8919-d20bc877b7ca_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.295504020074436, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.753636562958712, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d96577ec-a347-4d9e-b275-74c4e3582e5a", "name": "c16beac3-a33a-4ec1-b3c2-6dd358eb7e26", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3c5de08d-4489-4eff-9d3a-df139e6261fa"}}}]}, {"uuid": "deba2370-2c00-4278-9e40-74318b254dc7", "name": "load_p1rlv13051_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9a855b0-538e-4fab-91f1-93b4ece09409"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d96577ec-a347-4d9e-b275-74c4e3582e5a"}}}}, {"uuid": "2277f042-b321-4549-85c5-bfeefe010c0f", "name": "05b5aa46-f5c1-46a7-a7be-a0916dc3e831_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.295504020074436, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.753636562958712, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "386bd9d3-bf89-4d7f-95d5-9484beb56654", "name": "9ff705f6-657e-4c3b-a184-d722838b010d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2277f042-b321-4549-85c5-bfeefe010c0f"}}}]}, {"uuid": "e9e13a15-8f79-48f8-b00d-112c0955c7ff", "name": "load_p1rlv13051_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9a855b0-538e-4fab-91f1-93b4ece09409"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "386bd9d3-bf89-4d7f-95d5-9484beb56654"}}}}, {"uuid": "e47fc9f6-a620-41d6-8e5e-a4dea78f1d8c", "name": "02707f24-6de0-4f61-9067-fc376ceb4c35_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 19.860755218124574, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.283352762304049, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "90d2a991-1be9-4d3d-b25c-d641f5852ce0", "name": "98b94bea-0497-48c9-83cf-43dc2f58673e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e47fc9f6-a620-41d6-8e5e-a4dea78f1d8c"}}}]}, {"uuid": "c45e9911-1996-4701-87fe-231c8d794fe3", "name": "load_p1rlv13052_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86d59550-d7c8-47e1-a6bc-14b2d50de58c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "90d2a991-1be9-4d3d-b25c-d641f5852ce0"}}}}, {"uuid": "0b19b038-939c-4e2e-8045-86bfef6c145a", "name": "b60560c0-d5ed-443f-ae13-4cc320357fa6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 19.860755218124574, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.283352762304049, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fe9ce19d-3988-4f6f-acf3-8ac26188214c", "name": "21ef59b3-9520-42d9-a4b4-7d46fe81973d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0b19b038-939c-4e2e-8045-86bfef6c145a"}}}]}, {"uuid": "94a58535-40fd-430f-a363-0df23068f8eb", "name": "load_p1rlv13052_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86d59550-d7c8-47e1-a6bc-14b2d50de58c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fe9ce19d-3988-4f6f-acf3-8ac26188214c"}}}}, {"uuid": "8c55e953-e9d0-4f9a-afda-2b8357ad3322", "name": "e5be8e83-343d-4fe3-bd2d-f1ea52abcf56_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.272941497663945, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5660410395064467, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ec02be12-6aad-48e2-a97a-42a76367cb01", "name": "f2b0c48e-02b6-40cf-8f81-327201ddb0b1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8c55e953-e9d0-4f9a-afda-2b8357ad3322"}}}]}, {"uuid": "b030444d-c176-4df9-93ed-356fa73af275", "name": "load_p1rlv13053_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e058437-0138-4305-a33e-d8fa61aed8cc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ec02be12-6aad-48e2-a97a-42a76367cb01"}}}}, {"uuid": "b9a4594e-ecff-4fe1-abef-288a6ec861c7", "name": "a5ccbeed-776c-4cb9-9e01-d994993b293b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.272941497663945, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5660410395064467, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c7e076c8-071b-44a4-82b9-3a65877b8dfa", "name": "4b5acf6d-494a-47de-ad73-bfda2139e333", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b9a4594e-ecff-4fe1-abef-288a6ec861c7"}}}]}, {"uuid": "2593ff8d-6b0c-41be-bf36-255ad70efd32", "name": "load_p1rlv13053_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e058437-0138-4305-a33e-d8fa61aed8cc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c7e076c8-071b-44a4-82b9-3a65877b8dfa"}}}}, {"uuid": "b0c56a5f-1836-4722-a7a7-f077bf3f4645", "name": "d029c9ef-058f-4751-b3cd-a83bf3b24772_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.124330522658403, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7653447086077897, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "98e6961c-f75a-4769-bfdd-47154e878802", "name": "5b818057-a251-4108-ba28-169f909cd66b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b0c56a5f-1836-4722-a7a7-f077bf3f4645"}}}]}, {"uuid": "9839d392-3d5d-4f32-8fb9-d9cdcecf9708", "name": "load_p1rlv13054_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21c6ea4f-ec9d-424e-8743-7175408f9e2c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "98e6961c-f75a-4769-bfdd-47154e878802"}}}}, {"uuid": "13880019-47f5-4b84-9104-ca8a4447df61", "name": "ddc63b09-7b10-4163-87cc-483774534e70_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.124330522658403, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7653447086077897, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "11e31fd7-ec52-4f61-9efb-5a0f0e2a8a45", "name": "cc0e63a9-f9df-434a-bbf6-394f9c1a79ac", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "13880019-47f5-4b84-9104-ca8a4447df61"}}}]}, {"uuid": "4e56214a-a749-4596-8cee-c667bf524484", "name": "load_p1rlv13054_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21c6ea4f-ec9d-424e-8743-7175408f9e2c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "11e31fd7-ec52-4f61-9efb-5a0f0e2a8a45"}}}}, {"uuid": "03c39f62-f346-4ecf-87da-b9ca705e9875", "name": "9928165b-4e5b-4c16-8a43-36d49a23f7a1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.470164086158317, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2411725730358465, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c5708940-7781-463f-bcd1-37b6c01a4cf1", "name": "9746de90-03dd-4bd0-9bcb-c40970aad705", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "03c39f62-f346-4ecf-87da-b9ca705e9875"}}}]}, {"uuid": "dbd96bdb-7497-4e12-a129-f75678931540", "name": "load_p1rlv13055_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387df3d3-5f03-47f4-8b16-bea8815e63d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c5708940-7781-463f-bcd1-37b6c01a4cf1"}}}}, {"uuid": "6f125292-8e7d-415c-87ba-4b4ba7d74463", "name": "b9af170a-b3b6-4e59-9859-9f671b00ecdb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.470164086158317, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2411725730358465, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c10703b2-a476-4671-9c7d-3bc15b542600", "name": "93dd0309-9f55-4a16-adda-c7157a769eac", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6f125292-8e7d-415c-87ba-4b4ba7d74463"}}}]}, {"uuid": "1cf14206-e3aa-4595-b8ce-69a46738d4b2", "name": "load_p1rlv13055_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387df3d3-5f03-47f4-8b16-bea8815e63d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c10703b2-a476-4671-9c7d-3bc15b542600"}}}}, {"uuid": "99c97419-8203-4111-ab56-df4a04e8149f", "name": "b93feca9-d48c-4c0c-b938-910cd5a29adf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.8145950466373417, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09093602970127403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f4184d92-ab07-4d9b-803f-435931250b82", "name": "ef23f723-a264-4e32-9a5d-84f6b35da717", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "99c97419-8203-4111-ab56-df4a04e8149f"}}}]}, {"uuid": "284761d0-ff7d-48c2-8436-493918426886", "name": "load_p1rlv13056_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16584dfd-537d-4b0d-a651-c73d0beabc6d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f4184d92-ab07-4d9b-803f-435931250b82"}}}}, {"uuid": "81b1de48-f250-4a8e-9b53-21944e42f4ed", "name": "70ec6cdc-04cb-4891-bdeb-6b8d57f70743_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.8145950466373417, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09093602970127403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "19359e76-6088-4b0e-8f47-c33f8a19d2f8", "name": "ace47199-3291-4db6-bc3b-65e5536c2fd6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "81b1de48-f250-4a8e-9b53-21944e42f4ed"}}}]}, {"uuid": "367c65ab-12a7-4272-8839-3190caeb0b1e", "name": "load_p1rlv13056_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16584dfd-537d-4b0d-a651-c73d0beabc6d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "19359e76-6088-4b0e-8f47-c33f8a19d2f8"}}}}, {"uuid": "6c5c1197-8967-44f0-85b2-dd43d1bf8829", "name": "fcb5b0f9-8055-434e-a248-0b9d1358fa16_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b535f1cc-a786-4654-808f-1f463aae6dc8", "name": "841c3407-202a-4de9-8727-64ed789e4708", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c5c1197-8967-44f0-85b2-dd43d1bf8829"}}}]}, {"uuid": "31c3c8e3-e973-44e8-8690-5b04d68c366f", "name": "load_p1rlv13057_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c63d163-75bd-4d91-bcfa-229a2e331b1f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b535f1cc-a786-4654-808f-1f463aae6dc8"}}}}, {"uuid": "79a4a57b-5123-4f98-8e18-1d35c301ddd6", "name": "bc86e892-aced-4a06-b06e-d828beeab8ac_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "85960692-2cde-4d5a-b06e-e13af7db5812", "name": "fb457142-7b1a-4c62-a316-43045a4c6b27", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "79a4a57b-5123-4f98-8e18-1d35c301ddd6"}}}]}, {"uuid": "fd8f7923-db76-49bc-a8a3-66b4445c641e", "name": "load_p1rlv13057_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c63d163-75bd-4d91-bcfa-229a2e331b1f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "85960692-2cde-4d5a-b06e-e13af7db5812"}}}}, {"uuid": "72ea28b0-b695-4847-8b76-01579e4b31e6", "name": "cd345cd3-f1ff-41f5-a1a3-c11ab919a3e8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.875608242018149, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1961787734858456, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e9e358ae-8ebc-4bbc-aacf-73d7af4f2b43", "name": "468eefb5-0eb9-4a7c-a496-c98bd42b4734", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72ea28b0-b695-4847-8b76-01579e4b31e6"}}}]}, {"uuid": "a5e733fd-c2a1-42ae-a63b-4b11bfa9d4ad", "name": "load_p1rlv13058_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c83997dc-872f-494f-8c8a-7266c854fc48"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e9e358ae-8ebc-4bbc-aacf-73d7af4f2b43"}}}}, {"uuid": "fa7d9d10-6d78-4c79-8731-d4c36a133c7b", "name": "7d9a7113-b197-45a8-88c4-551125329b8a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.875608242018149, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1961787734858456, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7d1c59aa-705c-45c6-b82f-b7178e590441", "name": "a3343969-c521-4491-8340-33b943ea446a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fa7d9d10-6d78-4c79-8731-d4c36a133c7b"}}}]}, {"uuid": "fbd1c302-0e7e-41ea-8740-e1992463426f", "name": "load_p1rlv13058_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c83997dc-872f-494f-8c8a-7266c854fc48"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7d1c59aa-705c-45c6-b82f-b7178e590441"}}}}, {"uuid": "f0d8f92a-2aa8-4431-b312-ceb670228bc3", "name": "6e80263e-b0f6-4134-8069-1f1b7dbdc9d0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.516258392707745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.82351986644914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8d6d47de-9c11-42bd-853a-3d70debb739a", "name": "d4eb75ca-db27-4f11-a549-7e032883373b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f0d8f92a-2aa8-4431-b312-ceb670228bc3"}}}]}, {"uuid": "1c110a7c-5cdc-43a4-b1f8-747810ee5d26", "name": "load_p1rlv13059_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a1779b5b-1a6c-4511-9d4b-88026b430173"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8d6d47de-9c11-42bd-853a-3d70debb739a"}}}}, {"uuid": "8392a5f2-8483-4178-8754-587db4aabfb1", "name": "f1e5901c-94b7-463f-9101-552c870f7ba5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.516258392707745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.82351986644914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "818d8732-8073-4359-aa2a-4354c7097e22", "name": "3fd08c63-7fde-40fd-9774-52d88dda9756", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8392a5f2-8483-4178-8754-587db4aabfb1"}}}]}, {"uuid": "baecbf82-3a54-4bec-8e4f-b5150a2aaa5c", "name": "load_p1rlv13059_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a1779b5b-1a6c-4511-9d4b-88026b430173"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "818d8732-8073-4359-aa2a-4354c7097e22"}}}}, {"uuid": "4a61925b-63ad-4878-bc40-638e85e45994", "name": "5aa02a8b-c7a8-436e-a0a9-b6678a5c7f62_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3225810719994042, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7007930471414398, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1bfb56c0-4096-4c8c-8132-c0d23ee1f565", "name": "a962c033-de0a-49a5-938a-78efb020e111", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4a61925b-63ad-4878-bc40-638e85e45994"}}}]}, {"uuid": "a20be27f-4923-49db-83c7-31bc05844f05", "name": "load_p1rlv13060_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8767a040-da31-48d9-9473-0941856bcedc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1bfb56c0-4096-4c8c-8132-c0d23ee1f565"}}}}, {"uuid": "a0650809-8db7-442f-9baf-4b1823c29dac", "name": "11a2873e-9d09-40a4-88ec-071c2a439041_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3225810719994042, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7007930471414398, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "11e7c63b-d762-436a-ab74-35f68452aa97", "name": "c22d50fb-5daa-45ee-ae34-1913bc061277", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a0650809-8db7-442f-9baf-4b1823c29dac"}}}]}, {"uuid": "54f04642-4939-42fd-84ee-dc703d2e192c", "name": "load_p1rlv13060_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8767a040-da31-48d9-9473-0941856bcedc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "11e7c63b-d762-436a-ab74-35f68452aa97"}}}}, {"uuid": "f09616a9-d057-472b-be37-d3dde12abaa4", "name": "6818e893-548b-4084-ab88-2c7a3f9b4ae8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.20841006074213, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.2893238389393127, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "05d08ee4-9edf-462f-ab42-6f6ab946315a", "name": "6818e893-548b-4084-ab88-2c7a3f9b4ae8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.20841006074213, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.2893238389393127, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5b5f5f56-b919-4163-9f77-d0372d0dfc9c", "name": "6818e893-548b-4084-ab88-2c7a3f9b4ae8_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.20841006074213, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.2893238389393127, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7cbd7f03-3a65-4248-ac54-402c42382bd1", "name": "18abeb5f-69d6-4190-8139-c09f1ecb7b47", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f09616a9-d057-472b-be37-d3dde12abaa4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "05d08ee4-9edf-462f-ab42-6f6ab946315a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b5f5f56-b919-4163-9f77-d0372d0dfc9c"}}}]}, {"uuid": "aefdeb5a-7e28-4e59-a971-9e1880d00e58", "name": "load_p1rlv13061", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d46fd47-37f5-48a0-ba0d-d0746e6e6da3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7cbd7f03-3a65-4248-ac54-402c42382bd1"}}}}, {"uuid": "6a5e0cda-f071-41b3-89c3-bc3895ae79fd", "name": "0d619baf-e5ab-4247-ae0b-9be1dc720473_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c7020c42-d410-4138-b783-2833e5b95e5d", "name": "99999fa5-08e3-4da4-a649-53dbbd1068f7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6a5e0cda-f071-41b3-89c3-bc3895ae79fd"}}}]}, {"uuid": "95215704-3da1-4ebf-82f9-6059829ad086", "name": "load_p1rlv13062_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d2fa164-4c03-4bcd-a386-749ccd4e9001"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c7020c42-d410-4138-b783-2833e5b95e5d"}}}}, {"uuid": "46910cb5-2278-4ebc-b869-a4176999f6a2", "name": "8019d56f-4594-4922-9645-636324369ed9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "80fc95da-435d-45a0-a2c9-560a5a2f6aa0", "name": "27053b5a-0961-4ef7-a1fc-1cd4ecca27c1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "46910cb5-2278-4ebc-b869-a4176999f6a2"}}}]}, {"uuid": "b9c24b71-6e11-4019-8154-506058e4c412", "name": "load_p1rlv13062_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d2fa164-4c03-4bcd-a386-749ccd4e9001"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "80fc95da-435d-45a0-a2c9-560a5a2f6aa0"}}}}, {"uuid": "f455affc-aa35-47f2-9204-d82535afe51e", "name": "f7144831-4e15-4ed2-aedc-52b063299ed5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7083181921938193, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5666922324635131, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d410a840-d501-424e-866e-c57fd35ed41b", "name": "62e4edf4-f84f-4ca5-b758-65ce2968d898", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f455affc-aa35-47f2-9204-d82535afe51e"}}}]}, {"uuid": "e1bdea92-19fa-4287-b18d-26335d377399", "name": "load_p1rlv13185_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c29c3206-b71d-41d1-8ad7-a693c8c25d4d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d410a840-d501-424e-866e-c57fd35ed41b"}}}}, {"uuid": "2e60e5d6-561c-42b0-8601-c04b7998b6c8", "name": "352fe72c-c94f-441e-84ce-c82499836e28_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7083181921938193, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5666922324635131, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f4f3c19-5175-404f-9c92-e25705eb2ba8", "name": "defe891f-b26d-4dbc-9a31-c5346d2e5ce6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2e60e5d6-561c-42b0-8601-c04b7998b6c8"}}}]}, {"uuid": "38d145c4-18bd-4d9e-a258-5ecd2fd7429b", "name": "load_p1rlv13185_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c29c3206-b71d-41d1-8ad7-a693c8c25d4d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f4f3c19-5175-404f-9c92-e25705eb2ba8"}}}}, {"uuid": "cb8dd4b9-478e-47ca-9faa-4093149e4ba4", "name": "6d4551ec-1524-4d41-a79c-0698ba79ae98_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.774034588817963, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.005441618856208, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0367dad2-f61f-42d8-84b1-beb3a9f41e18", "name": "7ec19d5f-61eb-4752-b91e-7418eebc93a8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cb8dd4b9-478e-47ca-9faa-4093149e4ba4"}}}]}, {"uuid": "c488ff8d-b283-48e1-926a-a87c8c8c974d", "name": "load_p1rlv13187_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ffbd17b6-b1a2-4e55-9052-67a84419bb9d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0367dad2-f61f-42d8-84b1-beb3a9f41e18"}}}}, {"uuid": "44ac4961-909d-4886-bad7-ad68cddce4d2", "name": "b5cd8e31-7da9-43c0-a8b3-2d09ba56c7c0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.774034588817963, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.005441618856208, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "71866af3-3b03-49b5-8ed8-2fcb0c02fb5d", "name": "0a7ca848-f6e4-4330-b1ba-bcc12a3de282", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "44ac4961-909d-4886-bad7-ad68cddce4d2"}}}]}, {"uuid": "7f56d7c7-f838-4fcb-89c1-2d348c29a4c7", "name": "load_p1rlv13187_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ffbd17b6-b1a2-4e55-9052-67a84419bb9d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "71866af3-3b03-49b5-8ed8-2fcb0c02fb5d"}}}}, {"uuid": "90accc6c-537a-4e94-b3d9-599bc4d64d05", "name": "4038a0af-b705-4717-9396-d519d296d2bd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.028781788264419, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6709073147144231, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1f1260f7-8479-4de9-9e97-75aad039f9d2", "name": "b06a4187-870a-460c-b8eb-49f511949b47", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "90accc6c-537a-4e94-b3d9-599bc4d64d05"}}}]}, {"uuid": "abb8d875-6105-4ed3-8a3c-c50530500a31", "name": "load_p1rlv13188_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67ffcd9f-ba90-4da7-b3b6-46310e321590"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1f1260f7-8479-4de9-9e97-75aad039f9d2"}}}}, {"uuid": "3ed24d70-5c45-4cd8-92ce-2d822e741459", "name": "e40b61a4-2e7d-42de-a2ec-5134d7e60e86_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.028781788264419, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6709073147144231, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "66d43c17-fd3c-4cff-beed-d3cf878028df", "name": "908786ce-d194-4c28-a6cb-a687c3d12f93", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3ed24d70-5c45-4cd8-92ce-2d822e741459"}}}]}, {"uuid": "9719e5cb-9795-4a7a-bdea-f89f7f132c4c", "name": "load_p1rlv13188_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67ffcd9f-ba90-4da7-b3b6-46310e321590"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "66d43c17-fd3c-4cff-beed-d3cf878028df"}}}}, {"uuid": "749e6bd0-8c6d-4d4f-be52-4afd163f1e24", "name": "c9a3c089-66dc-4582-8ede-10c963e974e4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6702758059963014, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.7275069224848631, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dab591e8-b136-4923-a683-e9971efb1b7c", "name": "3fa3ab7c-8f40-43ca-9727-3fbeca5f3e7b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "749e6bd0-8c6d-4d4f-be52-4afd163f1e24"}}}]}, {"uuid": "7d6f4ffd-ea62-44ad-940b-8f4102b7b3c6", "name": "load_p1rlv13189_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "268361f6-d5ac-4002-80a6-f56f3b33599c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dab591e8-b136-4923-a683-e9971efb1b7c"}}}}, {"uuid": "9a5cacf7-835a-49cf-acd7-b750f5c58c18", "name": "ab341bf9-86dc-4140-a854-37cb7399eacb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6702758059963014, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.7275069224848631, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1012a10a-56cf-4ac9-9911-897ba8019bfb", "name": "44268273-eb53-429a-8f44-2a6a4a41b061", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9a5cacf7-835a-49cf-acd7-b750f5c58c18"}}}]}, {"uuid": "bca953e6-f28c-436e-b66c-e5009a64a975", "name": "load_p1rlv13189_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "268361f6-d5ac-4002-80a6-f56f3b33599c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1012a10a-56cf-4ac9-9911-897ba8019bfb"}}}}, {"uuid": "395a2561-b788-4737-9b64-e078b6546749", "name": "e3699a39-4ba1-4a3c-bf6d-2e51ffb98753_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.667455481738122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8122169683202977, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "35ed602a-8684-4906-8cc5-28d4667ee3d0", "name": "fecd8dfc-615e-4e60-aa7f-ad1c564bd08e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "395a2561-b788-4737-9b64-e078b6546749"}}}]}, {"uuid": "a2a392ac-8ce7-4c1f-89fb-f905f3fcfbc4", "name": "load_p1rlv13190_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3dbc593c-3949-4fa4-8738-d92540dbf998"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "35ed602a-8684-4906-8cc5-28d4667ee3d0"}}}}, {"uuid": "fafb4c38-c350-42f5-b9bf-65b115e4be2a", "name": "75db384a-c407-4fe0-b583-acac860ef089_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.667455481738122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8122169683202977, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "edb4253e-fdd3-411f-990e-16e38c36492c", "name": "5fca91c1-9303-45b0-9c0a-6a572f1e48a2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fafb4c38-c350-42f5-b9bf-65b115e4be2a"}}}]}, {"uuid": "f2da2ffb-270d-4757-bbf1-9064b5ccbad5", "name": "load_p1rlv13190_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3dbc593c-3949-4fa4-8738-d92540dbf998"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "edb4253e-fdd3-411f-990e-16e38c36492c"}}}}, {"uuid": "15e0ada5-9a29-4e07-97ec-108affc305b4", "name": "500052cb-f666-4032-a2b2-bab8b21a3486_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.921717825926216, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5520868751081406, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "34f6ee7b-b630-4c41-93d1-81d672c2eb6a", "name": "d32ebdcd-458d-46eb-809d-09c340eac5ad", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "15e0ada5-9a29-4e07-97ec-108affc305b4"}}}]}, {"uuid": "6ef49a1a-54aa-4ea5-b8ec-a869524870c2", "name": "load_p1rlv13191_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f6d09e9-3592-4560-8626-0d7cb71ca56a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "34f6ee7b-b630-4c41-93d1-81d672c2eb6a"}}}}, {"uuid": "b91f19a4-1fa5-42e2-bc4c-63d94394b78b", "name": "293b3bea-f770-484c-af08-4aa060d931cf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.921717825926216, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5520868751081406, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "21b89c3c-7d8f-44f2-be4c-2729adb154b6", "name": "855faf25-9d72-460b-81f3-1f2d5b31611a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b91f19a4-1fa5-42e2-bc4c-63d94394b78b"}}}]}, {"uuid": "13399b76-ec3f-4106-959d-3a94f7c1ce5f", "name": "load_p1rlv13191_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f6d09e9-3592-4560-8626-0d7cb71ca56a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "21b89c3c-7d8f-44f2-be4c-2729adb154b6"}}}}, {"uuid": "9feed621-db52-4acd-aa85-7f7d9f2ec289", "name": "cdbb55a3-b472-4d02-925d-3f772077109b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5300176124233262, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6781680527999017, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "048611e6-65d1-4c10-a692-96661c2a8918", "name": "d17a7a92-cbd8-4c79-9bdc-cc7740946c9b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9feed621-db52-4acd-aa85-7f7d9f2ec289"}}}]}, {"uuid": "4f0ccd3a-8be6-405b-985a-749cf90427ca", "name": "load_p1rlv13194_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d5ba889-d8f7-44ca-86b2-40939fa95df2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "048611e6-65d1-4c10-a692-96661c2a8918"}}}}, {"uuid": "2475c74c-94c4-46d5-8d6d-bac499071094", "name": "8e9d3c6d-fe0b-4f56-bb2b-6ce8739d7903_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5300176124233262, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6781680527999017, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "adda3498-b470-40e0-ad6d-84898623c771", "name": "d70c74cf-2de6-4495-8cb0-9eb84d9b96d0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2475c74c-94c4-46d5-8d6d-bac499071094"}}}]}, {"uuid": "e20cfae8-25b8-4116-9fe0-d5f20ebe404a", "name": "load_p1rlv13194_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d5ba889-d8f7-44ca-86b2-40939fa95df2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "adda3498-b470-40e0-ad6d-84898623c771"}}}}, {"uuid": "bbf7c688-0003-4d2e-8ecd-7359df36e721", "name": "c3def5f5-ec1e-4744-82c5-7166a5e86bde_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5670847441713207, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5540004468841006, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4abf7b78-c528-4955-94e5-48b90677531d", "name": "7880990d-bbf5-4fb9-98dc-41446ae0eaa8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bbf7c688-0003-4d2e-8ecd-7359df36e721"}}}]}, {"uuid": "5edc1716-e850-46c9-a684-263e46e62c9f", "name": "load_p1rlv13195_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e3e10c6-6ce2-4efa-be50-80e8b9bffe29"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4abf7b78-c528-4955-94e5-48b90677531d"}}}}, {"uuid": "02148270-d3f4-4c59-a2db-180eaa5f6e7d", "name": "0ab68643-d170-4d11-9c01-c0b81c3e2af2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5670847441713207, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5540004468841006, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2c5372b0-f45f-4a43-85e2-dde672b97a62", "name": "d1c9efd6-80e1-43dc-8b93-a1edd8d4263f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "02148270-d3f4-4c59-a2db-180eaa5f6e7d"}}}]}, {"uuid": "490acbcf-dec4-4965-9313-3498325efe09", "name": "load_p1rlv13195_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e3e10c6-6ce2-4efa-be50-80e8b9bffe29"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2c5372b0-f45f-4a43-85e2-dde672b97a62"}}}}, {"uuid": "6ae648fb-d09e-4c41-87e0-ca3a8d0da424", "name": "43c5e241-13d0-45b1-bce1-197bff3fa4ed_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.565985425671141, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8139237791533422, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "16e574a4-551a-4860-bf7f-1b8f4617b7ab", "name": "2875abd9-9f4b-4fcc-a8c8-6c53d49e4ae6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6ae648fb-d09e-4c41-87e0-ca3a8d0da424"}}}]}, {"uuid": "44c680a2-9eeb-4116-b0d5-0e2bba96cec1", "name": "load_p1rlv13196_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27013147-3d8f-4d75-a7a7-24457dc6d62a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "16e574a4-551a-4860-bf7f-1b8f4617b7ab"}}}}, {"uuid": "68149fca-3636-4d63-9aaf-a9776af7b4e5", "name": "7b062a3e-0dc2-44f1-8468-4e827b78a170_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.565985425671141, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8139237791533422, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "39d7fb73-eecd-4c90-a1b8-eea91fa80906", "name": "e2a1874f-f68a-4327-92c9-7c5bd349cba2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "68149fca-3636-4d63-9aaf-a9776af7b4e5"}}}]}, {"uuid": "18e6f764-9dc2-401a-aca6-387a640cb498", "name": "load_p1rlv13196_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27013147-3d8f-4d75-a7a7-24457dc6d62a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "39d7fb73-eecd-4c90-a1b8-eea91fa80906"}}}}, {"uuid": "cd3bf1f7-178e-4e37-af1c-71ee3fda84e2", "name": "8676102d-bd6e-4b64-8139-35261d0b516a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.88875250566531, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3533612733571443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3cb4cecc-fd03-46ca-8a7a-11f6d3c25706", "name": "6f4eef1e-5b06-427a-84e7-3dff9c0dd9ce", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cd3bf1f7-178e-4e37-af1c-71ee3fda84e2"}}}]}, {"uuid": "86dc39cd-37d2-4751-b049-62efd6d1d044", "name": "load_p1rlv13197_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b077d0f-74ec-4a04-8eb8-cf02ad16077d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3cb4cecc-fd03-46ca-8a7a-11f6d3c25706"}}}}, {"uuid": "00470f98-ca1d-4fe8-9eed-62ae6a5acb98", "name": "d9e8a415-8eb6-413a-bf6d-0d82fe874249_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.88875250566531, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3533612733571443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2d6ec1b4-1f84-43d0-a8f9-f697149b8cd9", "name": "65b56eab-9f11-4f42-820b-a98de379bc18", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "00470f98-ca1d-4fe8-9eed-62ae6a5acb98"}}}]}, {"uuid": "4941ce80-fbd4-4920-9b61-4a7973328dd5", "name": "load_p1rlv13197_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b077d0f-74ec-4a04-8eb8-cf02ad16077d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2d6ec1b4-1f84-43d0-a8f9-f697149b8cd9"}}}}, {"uuid": "d2d312dd-e429-44ee-b1da-478fe98a0d04", "name": "6b12e10f-4c38-48df-8729-363a813877c5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5401800544546385, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5525745253976501, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0e2ff513-8470-4dd8-bb10-1303f457ef6d", "name": "a4a5ac02-22f4-4b08-aa51-dd56d2eb35b5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d2d312dd-e429-44ee-b1da-478fe98a0d04"}}}]}, {"uuid": "ab52a8d9-56d7-4505-96f6-43958c808cbb", "name": "load_p1rlv13199_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad7545fb-8a41-4ed7-a178-e90f19bfa9d5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0e2ff513-8470-4dd8-bb10-1303f457ef6d"}}}}, {"uuid": "f5108d12-4535-409d-89cf-f89b367b6bb8", "name": "0c23895e-b538-43eb-9188-29f3b222bf8a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5401800544546385, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5525745253976501, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4024c612-bd14-466c-99e8-09f9b24f32bb", "name": "c2842eae-ba25-4847-bfa8-2fc534e875b6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f5108d12-4535-409d-89cf-f89b367b6bb8"}}}]}, {"uuid": "680b353e-4b9e-4cfd-8563-474184c7c4a4", "name": "load_p1rlv13199_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad7545fb-8a41-4ed7-a178-e90f19bfa9d5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4024c612-bd14-466c-99e8-09f9b24f32bb"}}}}, {"uuid": "5836d2d8-73bf-4713-aa19-2ebdb75d814e", "name": "3aa35252-4a62-4093-a046-1f26b5cccc96_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4622944887503224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10483650830237357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f3830231-d432-4ea1-a877-c43e1eb23c26", "name": "4406571f-ea0c-40d5-a95f-1d6ff0358e22", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5836d2d8-73bf-4713-aa19-2ebdb75d814e"}}}]}, {"uuid": "0cdce4ca-4ae0-4ef2-ab2e-21943cabf260", "name": "load_p1rlv13200_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fed30a3f-12a5-4545-b5d5-5c13a131a256"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f3830231-d432-4ea1-a877-c43e1eb23c26"}}}}, {"uuid": "24e9efc8-e540-453e-9c06-acb8376f8c87", "name": "e00d3e41-118b-4b67-9282-585e3a1062a6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4622944887503224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10483650830237357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e3e004c0-59f7-4008-bfc3-b21a8a3c2ec1", "name": "e944d3f7-b958-4ad8-babc-f3b650222041", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "24e9efc8-e540-453e-9c06-acb8376f8c87"}}}]}, {"uuid": "5cbfb4b6-8fe8-4226-9c2b-6a740d74a7dc", "name": "load_p1rlv13200_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fed30a3f-12a5-4545-b5d5-5c13a131a256"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e3e004c0-59f7-4008-bfc3-b21a8a3c2ec1"}}}}, {"uuid": "bf2b6285-13cf-417c-9019-df8d6d921784", "name": "72893fec-4075-4f0c-8439-ec735f3c3781_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.195601026095605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4379463760124337, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0690c0af-36e8-4faf-9931-a3452f52186f", "name": "b34d8a4c-b257-436f-8c55-a9c836295b91", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bf2b6285-13cf-417c-9019-df8d6d921784"}}}]}, {"uuid": "3c26dedc-4fc5-4269-ac0d-51bb1fe00d43", "name": "load_p1rlv13201_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cdd7c49-e758-4009-8db5-d0b5748f919c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0690c0af-36e8-4faf-9931-a3452f52186f"}}}}, {"uuid": "0381ba9f-4f61-4e8b-8f3e-33df9c63f2be", "name": "9255e6bf-8dac-41ed-818f-a3af6456b1a5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.195601026095605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4379463760124337, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1bb6d719-9f60-4715-acf7-328790d4356c", "name": "9c0ddcdd-a56e-4be5-a7dd-f0299fc3231b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0381ba9f-4f61-4e8b-8f3e-33df9c63f2be"}}}]}, {"uuid": "95beee2e-b0cd-4efd-a08f-b5aa0d3b96a2", "name": "load_p1rlv13201_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cdd7c49-e758-4009-8db5-d0b5748f919c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1bb6d719-9f60-4715-acf7-328790d4356c"}}}}, {"uuid": "f03edf52-7271-4a3e-ae1f-53a895760067", "name": "acb7d454-6f87-41e9-9a36-d2c551b386b6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8140414184691503, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34693077623207685, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7fe60fff-7fd7-4d9d-9182-8c33ae3cc32f", "name": "dab218dc-48d1-42fd-97bc-69e46edfd8ee", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f03edf52-7271-4a3e-ae1f-53a895760067"}}}]}, {"uuid": "9702e0ce-9c9a-4469-a0a1-a78d4c62d7f2", "name": "load_p1rlv13316_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473b080b-1412-40dc-a452-09d43a462098"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7fe60fff-7fd7-4d9d-9182-8c33ae3cc32f"}}}}, {"uuid": "3d64967f-5c6c-4c44-baff-4cea9d9023d4", "name": "ee63e168-4c6b-458f-9279-3f5f3a415f27_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8140414184691503, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34693077623207685, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d71051fc-5760-4907-b6d4-890667fc0d5b", "name": "048ee0ab-8d53-47d7-b9ed-62a8e4068d7b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3d64967f-5c6c-4c44-baff-4cea9d9023d4"}}}]}, {"uuid": "b6dbfe6e-a255-4b3a-b58c-e03141eab622", "name": "load_p1rlv13316_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473b080b-1412-40dc-a452-09d43a462098"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d71051fc-5760-4907-b6d4-890667fc0d5b"}}}}, {"uuid": "dac1c5ce-10b4-4584-9591-5e05bef98c5d", "name": "937de26d-9b11-4d11-ab4a-279351ae6c89_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a0c87f0-5315-4a11-85e7-c6b554c99a2b", "name": "fcf85268-ac67-4816-9093-b27b458df88f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dac1c5ce-10b4-4584-9591-5e05bef98c5d"}}}]}, {"uuid": "edc77fc3-e069-4d18-96c9-61760d32f742", "name": "load_p1rlv13597_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "353889fb-da44-4cf8-ae0e-d20541f36d7e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0a0c87f0-5315-4a11-85e7-c6b554c99a2b"}}}}, {"uuid": "26e8b0dc-2ac3-4742-ac43-55c0bb67b561", "name": "e0a5dbc6-77a6-4835-998c-1543298e0f8f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d9e348bd-8fff-4da1-98f1-8a90ff9da829", "name": "7ac170e6-bc12-4fef-b7e3-5c414b03ece6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "26e8b0dc-2ac3-4742-ac43-55c0bb67b561"}}}]}, {"uuid": "1d33447a-cabc-4c04-8811-f06c7603e54e", "name": "load_p1rlv13597_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "353889fb-da44-4cf8-ae0e-d20541f36d7e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d9e348bd-8fff-4da1-98f1-8a90ff9da829"}}}}, {"uuid": "37c4d4ed-d4bc-46ee-b908-0a71a5aa6518", "name": "800bea90-02ed-4d86-a2d7-34d14bf5aad6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "041a363b-8459-4191-a6f5-4685aeb8936b", "name": "ecc00417-30b1-427f-a6f3-81ae9febefaf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "37c4d4ed-d4bc-46ee-b908-0a71a5aa6518"}}}]}, {"uuid": "6033b316-93cf-415e-841e-82f4e21dbc25", "name": "load_p1rlv13598_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59953c2f-244e-4bb8-ab24-b28d82b195e1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "041a363b-8459-4191-a6f5-4685aeb8936b"}}}}, {"uuid": "c7f4cc2e-d190-4b9b-82c7-99a025144f6e", "name": "3e28f879-bbd7-4454-b56a-0e32fb67f207_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4913cce6-590b-4348-900a-b797faf546fd", "name": "20331403-4b6e-4cf2-837a-2862b0536e98", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c7f4cc2e-d190-4b9b-82c7-99a025144f6e"}}}]}, {"uuid": "63dca524-7496-41cc-9c8c-adcfbbe727bc", "name": "load_p1rlv13598_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59953c2f-244e-4bb8-ab24-b28d82b195e1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4913cce6-590b-4348-900a-b797faf546fd"}}}}, {"uuid": "c88ab96a-c49c-422b-bfd3-498b6fc68c01", "name": "1e50911e-2f5c-4f91-8819-6bbb0a799416_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cb268438-07b7-4715-968d-4f6ab65bcc52", "name": "49bf7cd1-6dfb-4119-b3d1-0f9ba6162d72", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c88ab96a-c49c-422b-bfd3-498b6fc68c01"}}}]}, {"uuid": "9be21e16-3c8d-4128-ab14-c6911cd8c684", "name": "load_p1rlv13599_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2a60818-4310-4100-9aa8-35ef37aa5f40"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cb268438-07b7-4715-968d-4f6ab65bcc52"}}}}, {"uuid": "bfcd7e85-efbc-4cfa-b47b-9ae669d6966c", "name": "bc0bb68d-ed14-4e89-9996-9bb3483c92c5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5e70eb0d-153f-4fb3-a538-2b0c4a1dc9fc", "name": "c3e6a5e6-3a47-4917-9dba-1bb6074677eb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bfcd7e85-efbc-4cfa-b47b-9ae669d6966c"}}}]}, {"uuid": "bdc775ec-84d1-4a2c-bb98-c1e19e71da3c", "name": "load_p1rlv13599_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2a60818-4310-4100-9aa8-35ef37aa5f40"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5e70eb0d-153f-4fb3-a538-2b0c4a1dc9fc"}}}}, {"uuid": "86a1a85e-300d-4da9-84ff-1fe5a2e5461f", "name": "c7009d2b-05c2-440b-b854-afa1d3a88ecb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.940151571607843, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7360323556900852, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3b91ff6a-d898-4df2-b1d2-53ce9e03bb81", "name": "348b7989-2c3f-46ef-b687-739cb14395a3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "86a1a85e-300d-4da9-84ff-1fe5a2e5461f"}}}]}, {"uuid": "e17443e8-f800-420d-803b-6bd11600508f", "name": "load_p1rlv13600_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59ab6d81-a91c-4350-8f94-abe02e3e1555"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3b91ff6a-d898-4df2-b1d2-53ce9e03bb81"}}}}, {"uuid": "34d0ec8c-f568-4d5b-81ed-0a449f709d4e", "name": "61bad4c4-8759-486c-8089-62cce9f8522a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.940151571607843, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7360323556900852, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "928b9698-5fd4-4dcb-b44f-e91ba1da74bc", "name": "e1242757-0cfe-4113-96b9-c8744221d741", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "34d0ec8c-f568-4d5b-81ed-0a449f709d4e"}}}]}, {"uuid": "7ecbba76-6fc2-4902-8f7e-ed8a8223ba90", "name": "load_p1rlv13600_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59ab6d81-a91c-4350-8f94-abe02e3e1555"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "928b9698-5fd4-4dcb-b44f-e91ba1da74bc"}}}}, {"uuid": "95ebc42e-d8ed-4efc-9e8d-d01fdf170ded", "name": "0ceedc81-bfb3-4288-961c-0e49525bf1d9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.872515319591797, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7328111219910317, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bf6f99c3-a9c4-4e4b-820c-a2e12bfe4966", "name": "f3195a99-0a13-4b39-8ab3-dc1c65446089", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "95ebc42e-d8ed-4efc-9e8d-d01fdf170ded"}}}]}, {"uuid": "fb643b41-122e-4bf0-b101-29d55e2bc232", "name": "load_p1rlv13601_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91953a27-bbc7-494a-bec2-a12b4c0f6af6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bf6f99c3-a9c4-4e4b-820c-a2e12bfe4966"}}}}, {"uuid": "07ad6e5f-b4ba-43fc-8288-53ecc9792bdd", "name": "b9747aa8-2e9e-4db4-94d7-2b04e560536a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.872515319591797, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7328111219910317, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "51667fa2-0da1-4cca-ad8a-6a60cfc43683", "name": "4cef8fd1-a3ff-4f2b-abb8-d9bcf4da4242", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "07ad6e5f-b4ba-43fc-8288-53ecc9792bdd"}}}]}, {"uuid": "b5b4f2e8-4da2-4bb5-9f06-43efb167b2a9", "name": "load_p1rlv13601_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91953a27-bbc7-494a-bec2-a12b4c0f6af6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "51667fa2-0da1-4cca-ad8a-6a60cfc43683"}}}}, {"uuid": "ea1ce7af-6d0a-423b-bc32-74905847c262", "name": "b61e5da4-890c-407d-a6f0-8fd358dda581_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.308477864741614, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307751830484037, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a45011c6-1d24-462b-99f0-9537120e1f35", "name": "614283b0-7844-438c-9863-4124f7dfc777", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ea1ce7af-6d0a-423b-bc32-74905847c262"}}}]}, {"uuid": "5402fdc5-a823-41d7-9db4-622ed2bf74bf", "name": "load_p1rlv13604_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9b83bdf-b564-4997-bfc7-1be2f2e58199"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a45011c6-1d24-462b-99f0-9537120e1f35"}}}}, {"uuid": "7378b82f-38ce-4c28-a550-c37b78d7b46c", "name": "86fa24a9-15a6-4d02-b561-bb5e1e8eba63_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.308477864741614, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307751830484037, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "13368055-1611-4a68-a552-3ecc6be93c50", "name": "58a60a73-ac22-4a59-9aa9-d024c3804259", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7378b82f-38ce-4c28-a550-c37b78d7b46c"}}}]}, {"uuid": "6c4e0cf3-fbb2-48bd-a319-e909a6b7afdc", "name": "load_p1rlv13604_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9b83bdf-b564-4997-bfc7-1be2f2e58199"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "13368055-1611-4a68-a552-3ecc6be93c50"}}}}, {"uuid": "96374ea5-49ab-4bb4-9b0f-e042b6f86caf", "name": "d2525f13-738e-4d5c-8557-092bc2a7aea9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0263288002917053, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.546221099657035, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6ac379df-438b-4c9a-9cee-907cb9ac2b96", "name": "d690a139-4ae2-45e1-9f14-79bf3d186cd3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "96374ea5-49ab-4bb4-9b0f-e042b6f86caf"}}}]}, {"uuid": "aa4e9307-1124-451d-bab1-24bd64df40db", "name": "load_p1rlv13605_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c39dc6f1-08b5-4bc1-a6ae-be0076af56aa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6ac379df-438b-4c9a-9cee-907cb9ac2b96"}}}}, {"uuid": "30529f9d-37bc-4c22-9856-0356ce450b19", "name": "2d6e29aa-c304-4568-a7ce-9e4ceaebc081_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0263288002917053, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.546221099657035, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "232736c1-342b-4abb-815a-85de36131904", "name": "cbb570ad-e05a-49e4-af04-6f5c1e6881c1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "30529f9d-37bc-4c22-9856-0356ce450b19"}}}]}, {"uuid": "88f60a05-1c81-46dc-b19b-d233db420470", "name": "load_p1rlv13605_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c39dc6f1-08b5-4bc1-a6ae-be0076af56aa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "232736c1-342b-4abb-815a-85de36131904"}}}}, {"uuid": "263e7d44-927e-42de-9b33-bc043e89c1c4", "name": "9a2d242b-b087-4c69-8f6d-278d9910f3d0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3058115791316, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6614039959360709, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3da29d94-7b41-43c1-93a6-dfa9f53858d7", "name": "9aa3ae61-c7b5-47b7-aa9d-5c8c80616f35", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "263e7d44-927e-42de-9b33-bc043e89c1c4"}}}]}, {"uuid": "513733d5-ddd6-4f64-84e2-3b9839127ace", "name": "load_p1rlv13606_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29838633-5c95-4b73-8227-cfa7f4aedc32"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3da29d94-7b41-43c1-93a6-dfa9f53858d7"}}}}, {"uuid": "c3508a5a-022c-43f9-9b4e-2ae2096aaa94", "name": "2aab3bd4-5cf8-4bcd-8736-1ba0c8b52714_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3058115791316, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6614039959360709, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "db7406f9-285f-4b88-a7df-591a5a6e057e", "name": "7e72a4ff-304d-46fd-b528-4db1ec619d00", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c3508a5a-022c-43f9-9b4e-2ae2096aaa94"}}}]}, {"uuid": "c3367ac3-ed0f-4f82-9322-d35372941dad", "name": "load_p1rlv13606_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29838633-5c95-4b73-8227-cfa7f4aedc32"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "db7406f9-285f-4b88-a7df-591a5a6e057e"}}}}, {"uuid": "d7118512-4d9f-4803-a23a-381c995f83d5", "name": "8f5f7a71-ef92-4554-b3f5-ec6859e30f41_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a684586-7b36-4a30-97ad-40077a5b1a2a", "name": "8bd626f0-1c1f-4b3d-97d1-a826eba24e2a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d7118512-4d9f-4803-a23a-381c995f83d5"}}}]}, {"uuid": "e224fb14-299d-47f6-9ef1-eda559eb944e", "name": "load_p1rlv13608_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5e8caf4-4d81-4bbd-98df-6622c5ad0563"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a684586-7b36-4a30-97ad-40077a5b1a2a"}}}}, {"uuid": "28630b53-5791-4151-9f80-b012654e5bbe", "name": "22d967d4-e19a-4c1e-8516-2630a06cb526_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "17a1254d-30de-4ff2-9c67-8f9c56bcdcdb", "name": "b8b4fca4-7ce8-4b31-8cea-14e2ee0c4126", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "28630b53-5791-4151-9f80-b012654e5bbe"}}}]}, {"uuid": "9e615355-12ee-4e44-8d83-55496ef1fcf3", "name": "load_p1rlv13608_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5e8caf4-4d81-4bbd-98df-6622c5ad0563"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "17a1254d-30de-4ff2-9c67-8f9c56bcdcdb"}}}}, {"uuid": "1feccc53-8a55-4dc6-9f14-4cf6e7aeebdc", "name": "8e9ec97c-4e8e-477f-ae8c-95e2d6519669_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5204227867871802, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7134940441409878, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "efc5b363-454a-4a41-938c-d9814f2c1f71", "name": "56b8d8b3-7160-498a-adf8-e9d5489fc83e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1feccc53-8a55-4dc6-9f14-4cf6e7aeebdc"}}}]}, {"uuid": "db709395-c523-49cd-bc4c-951458b96c38", "name": "load_p1rlv13610_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17d92377-b4f1-4194-89cd-130bddb9b77c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "efc5b363-454a-4a41-938c-d9814f2c1f71"}}}}, {"uuid": "3d4a40ad-cf2f-48cc-91b8-c510fcfd720a", "name": "2f6e39fc-02dc-4ced-b0c9-d2e034212c8b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5204227867871802, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7134940441409878, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "22cf121f-0a5e-4231-a163-421c123a468b", "name": "ac3812fd-6712-48ea-a30a-3a72ae609341", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3d4a40ad-cf2f-48cc-91b8-c510fcfd720a"}}}]}, {"uuid": "30ca95f8-c26e-4560-b35e-048e5962d8eb", "name": "load_p1rlv13610_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17d92377-b4f1-4194-89cd-130bddb9b77c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "22cf121f-0a5e-4231-a163-421c123a468b"}}}}, {"uuid": "a9e4bce4-e5ea-4dbe-9c8b-0996a5871289", "name": "b0ee7b25-6a5f-4828-bb53-791e41cee671_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2489699911360574, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6200743429841856, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ace91704-0ee2-4020-8008-431ae1f26054", "name": "eebf7c81-db20-425a-8370-c45b1c52bb94", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a9e4bce4-e5ea-4dbe-9c8b-0996a5871289"}}}]}, {"uuid": "2f7690c2-b063-4a26-95de-fd6e37f8f5e8", "name": "load_p1rlv13611_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "630b2a63-622f-4f78-8390-77c69ba7e393"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ace91704-0ee2-4020-8008-431ae1f26054"}}}}, {"uuid": "38d953b6-3f7b-4e8e-be9a-ae293ecbf7d8", "name": "42816fc3-6691-4291-a26a-fc09ab7e3bc0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2489699911360574, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6200743429841856, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5dd03872-be94-4cdd-a533-e296b0ac4845", "name": "594456f4-453a-4fc6-af35-02d1f8ae5882", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "38d953b6-3f7b-4e8e-be9a-ae293ecbf7d8"}}}]}, {"uuid": "911a5c75-08be-456c-973b-9a4c69d19096", "name": "load_p1rlv13611_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "630b2a63-622f-4f78-8390-77c69ba7e393"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5dd03872-be94-4cdd-a533-e296b0ac4845"}}}}, {"uuid": "ceabb95c-76b6-47da-a2a5-4e08546fcc2b", "name": "025048b4-8552-4dc2-9bb0-12431180acd8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0788570276665777, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5949433355568994, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e582b791-1f79-4fe0-9652-895edb6344c8", "name": "d53d11c2-17ce-4f3c-a9fd-6078dad4bbd9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ceabb95c-76b6-47da-a2a5-4e08546fcc2b"}}}]}, {"uuid": "61c13545-2cec-4589-b92e-12a351832386", "name": "load_p1rlv13612_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6eda3e97-a618-41ab-ae55-ba67f6bb0234"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e582b791-1f79-4fe0-9652-895edb6344c8"}}}}, {"uuid": "38891ee9-4cab-4112-95d0-c271e8712dac", "name": "2a6196bf-11e5-4c12-ae76-cd971eb48e56_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0788570276665777, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5949433355568994, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2c0dfc31-f7c5-448a-b043-29789cc89020", "name": "7df2e922-0b73-4fa6-9815-4813fb83d211", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "38891ee9-4cab-4112-95d0-c271e8712dac"}}}]}, {"uuid": "950cc650-04a5-4d24-bcbe-53ff2c5a8a71", "name": "load_p1rlv13612_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6eda3e97-a618-41ab-ae55-ba67f6bb0234"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2c0dfc31-f7c5-448a-b043-29789cc89020"}}}}, {"uuid": "615db8c4-a370-422f-8b4d-781af51be9d4", "name": "ef027f39-0c3c-4bc3-8c3f-55acd3dc42f9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4038244377730775, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.30842299757959857, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "577b1b4d-48de-488a-b861-edbf0baf30ba", "name": "05b1a662-a415-49ce-a317-1d02d95e6738", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "615db8c4-a370-422f-8b4d-781af51be9d4"}}}]}, {"uuid": "dd4d943d-5659-4a56-b23f-4c946dda2361", "name": "load_p1rlv13613_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "216537dd-ea7b-461c-b821-99491c41b7f0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "577b1b4d-48de-488a-b861-edbf0baf30ba"}}}}, {"uuid": "5dc94bd8-c89f-4a2d-89cb-5ec7d3fd4fd5", "name": "a779b030-b0ef-4643-9c38-2a0b46685b34_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4038244377730775, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.30842299757959857, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "099b682b-fba1-4215-bfcf-8fc8cec8d482", "name": "858472de-7dc6-4d68-b184-da80b2f6fe29", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5dc94bd8-c89f-4a2d-89cb-5ec7d3fd4fd5"}}}]}, {"uuid": "3c640205-45c4-40ae-9e42-96ac27b81452", "name": "load_p1rlv13613_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "216537dd-ea7b-461c-b821-99491c41b7f0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "099b682b-fba1-4215-bfcf-8fc8cec8d482"}}}}, {"uuid": "c401073b-65fd-4fcc-a753-63093a15d2a7", "name": "aa64dd19-278b-4f71-b580-5e4a6d3dd375_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8b433e2b-9be7-4845-9f80-726834f5e0a3", "name": "80429f8b-4518-49fa-821e-18823aba8c08", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c401073b-65fd-4fcc-a753-63093a15d2a7"}}}]}, {"uuid": "513e3258-3983-4da3-bcc3-6daa810f2225", "name": "load_p1rlv13614_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3de8b994-01ba-4eae-b9cf-7fb174d32355"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8b433e2b-9be7-4845-9f80-726834f5e0a3"}}}}, {"uuid": "c8bf0b27-96cd-421f-8407-d565d173abd1", "name": "da73a03b-3f48-4f38-9384-ac4f10889abd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "650cf6ba-fe0c-4878-b263-0128aa0144d0", "name": "5a5810e9-1f98-404f-a07c-e1219374cffa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c8bf0b27-96cd-421f-8407-d565d173abd1"}}}]}, {"uuid": "7406de4a-2f49-4d2a-8c76-cafbe9ba85c2", "name": "load_p1rlv13614_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3de8b994-01ba-4eae-b9cf-7fb174d32355"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "650cf6ba-fe0c-4878-b263-0128aa0144d0"}}}}, {"uuid": "c661fa66-2f5a-43d5-99bf-3ff16796aaed", "name": "c0e4c6b3-3279-479f-ac5d-8dc382c17966_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5937162117629007, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7166618655640316, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7153f498-dbb9-489e-b8e7-8f16d884d4c2", "name": "e9e9f350-68d2-45c2-ba4d-47d5bba6f8e0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c661fa66-2f5a-43d5-99bf-3ff16796aaed"}}}]}, {"uuid": "f9a7de0e-1624-4e03-a4d4-0bf885f4db72", "name": "load_p1rlv13616_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "850d5b69-14cf-4a18-8cb0-4f1b3033b0aa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7153f498-dbb9-489e-b8e7-8f16d884d4c2"}}}}, {"uuid": "84568431-202f-46d3-a1a7-6cf36056966d", "name": "4c3f9928-dd45-4c08-8226-a9af82946f53_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5937162117629007, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7166618655640316, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4ff9e464-1d53-4124-aa0c-1d94088c75da", "name": "f60b7063-cd28-448b-8075-e90671f50e66", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "84568431-202f-46d3-a1a7-6cf36056966d"}}}]}, {"uuid": "63f4474e-0953-4d5e-b2d1-64cf24a77cc6", "name": "load_p1rlv13616_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "850d5b69-14cf-4a18-8cb0-4f1b3033b0aa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4ff9e464-1d53-4124-aa0c-1d94088c75da"}}}}, {"uuid": "0243729f-a4f3-4b56-a9ab-92767d1d70a5", "name": "6358a027-9c78-4156-8d36-a3bb6ae9dea7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.32403643380503, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6293121819683343, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ec564e10-1096-40d1-aabf-086dcfce9ad1", "name": "bfbd1fab-efe8-4742-9ec7-e067bf5b8101", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0243729f-a4f3-4b56-a9ab-92767d1d70a5"}}}]}, {"uuid": "9d936c16-a4ef-41d3-a02b-81a91da4ab6f", "name": "load_p1rlv13618_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f823a90c-effd-489c-9e0a-c110ccb7b9e8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ec564e10-1096-40d1-aabf-086dcfce9ad1"}}}}, {"uuid": "982da60c-87b4-4c34-ab26-f5fc1800475c", "name": "7d175011-18a2-48ee-9860-86faf3a84ead_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.32403643380503, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6293121819683343, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a60f819f-3886-44bb-b377-d01b1a10dbb7", "name": "b5976cb3-6e35-4410-b95d-deb0d34c43e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "982da60c-87b4-4c34-ab26-f5fc1800475c"}}}]}, {"uuid": "ecfe68a2-0142-4266-a254-a2845e55b700", "name": "load_p1rlv13618_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f823a90c-effd-489c-9e0a-c110ccb7b9e8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a60f819f-3886-44bb-b377-d01b1a10dbb7"}}}}, {"uuid": "1a69abb9-b58e-4d90-82f6-eb37166b9bd1", "name": "8fb1d5ac-e728-4989-a7bc-cee6ea816c78_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f3a8970e-e470-4043-80aa-fb20167e1294", "name": "5abaf938-70c7-4202-81f3-18640982dbd3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1a69abb9-b58e-4d90-82f6-eb37166b9bd1"}}}]}, {"uuid": "81bfac05-e086-4de0-83c9-c6e2a05cc9a7", "name": "load_p1rlv13619_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f693a1d2-5499-4810-9458-f205eda265fa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f3a8970e-e470-4043-80aa-fb20167e1294"}}}}, {"uuid": "26cc3290-18c5-492c-a8b9-e11d1ac7ae2b", "name": "d10fdde6-9faf-436f-8462-ad79941e50fd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50973f29-fe75-4d0e-9ddb-b975772b2ce8", "name": "afdb77a0-c05b-4936-8e17-42daaec74c50", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "26cc3290-18c5-492c-a8b9-e11d1ac7ae2b"}}}]}, {"uuid": "9e9747fe-1fab-4906-80cc-2990dc64a58d", "name": "load_p1rlv13619_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f693a1d2-5499-4810-9458-f205eda265fa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50973f29-fe75-4d0e-9ddb-b975772b2ce8"}}}}, {"uuid": "540b6425-7b6a-418a-9407-b741ccfbc1f0", "name": "331275d4-11df-4025-bd14-639b10811382_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3711169311548215, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.698133467399761, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dd8c0a0d-94a1-4a22-8ae4-7f99f1e72767", "name": "cba0580c-e34b-4136-934a-1954c8bef28e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "540b6425-7b6a-418a-9407-b741ccfbc1f0"}}}]}, {"uuid": "cd00aa99-b5c4-414d-8e55-6ec7ae7ed2cf", "name": "load_p1rlv13622_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4540b2cb-ee21-4515-a7ca-fbca371f060d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dd8c0a0d-94a1-4a22-8ae4-7f99f1e72767"}}}}, {"uuid": "b69fd5c7-dfe1-4a99-bafc-eeaa6547cdde", "name": "b932ded9-91ac-49b2-9cf7-60be0a24b0de_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3711169311548215, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.698133467399761, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b511ff2f-d16a-4da3-8c26-026b36bcf320", "name": "81520e07-1b5e-47f8-831d-fbc974227fc0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b69fd5c7-dfe1-4a99-bafc-eeaa6547cdde"}}}]}, {"uuid": "be39051c-160a-4255-82db-c4f94178fc78", "name": "load_p1rlv13622_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4540b2cb-ee21-4515-a7ca-fbca371f060d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b511ff2f-d16a-4da3-8c26-026b36bcf320"}}}}, {"uuid": "16db1fde-6327-40dc-b52c-9f4a9422dcab", "name": "b644319d-53f3-449a-8718-b090f40475ed_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6a2b4aa1-0e89-41f0-b2ee-237b8b4595cb", "name": "3194b37e-7435-4ed6-af61-d734630c7a8b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "16db1fde-6327-40dc-b52c-9f4a9422dcab"}}}]}, {"uuid": "823d3c38-d418-44a7-b3e7-990cef254e23", "name": "load_p1rlv13623_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80f60ab3-722f-4765-8b91-4fd0196171d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6a2b4aa1-0e89-41f0-b2ee-237b8b4595cb"}}}}, {"uuid": "6abe6328-7df4-44da-be3e-ba9d24e13cf2", "name": "5663592a-6245-44f0-8eec-b827b8056d8e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "386b9a03-f06a-44a2-8c0a-a07514b3e02c", "name": "efd73571-4bdf-4f76-8caa-8ca5bc2e86ce", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6abe6328-7df4-44da-be3e-ba9d24e13cf2"}}}]}, {"uuid": "a548b0cf-d329-424c-9939-c106e24fd913", "name": "load_p1rlv13623_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80f60ab3-722f-4765-8b91-4fd0196171d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "386b9a03-f06a-44a2-8c0a-a07514b3e02c"}}}}, {"uuid": "6353637a-3b3c-4a60-98ca-da3849ffab62", "name": "83606068-7e13-44f5-bd59-8eb99d849b7e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.611133182200907, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.07668264048246332, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5e111da4-7213-4700-aef8-69237ad31af7", "name": "55b70704-76f8-4604-abe8-e6358eb78676", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6353637a-3b3c-4a60-98ca-da3849ffab62"}}}]}, {"uuid": "87bf233e-57f9-4173-b00a-ad70cdf98074", "name": "load_p1rlv13624_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a5746d1-24a6-4ae4-b5dc-cef23b56660d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5e111da4-7213-4700-aef8-69237ad31af7"}}}}, {"uuid": "e7d644a0-c392-4633-988e-6be09deff0c3", "name": "035df44e-9561-422c-998f-a75dbe9ae4d4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.611133182200907, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.07668264048246332, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dd42cc15-e607-43c0-abb3-28e853c03221", "name": "fd2bc551-42c3-4ced-98c1-ba15d124bc6f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e7d644a0-c392-4633-988e-6be09deff0c3"}}}]}, {"uuid": "32fa6b51-eaaf-436a-bf91-636c328ee365", "name": "load_p1rlv13624_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a5746d1-24a6-4ae4-b5dc-cef23b56660d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dd42cc15-e607-43c0-abb3-28e853c03221"}}}}, {"uuid": "de0e49fe-3bdc-4a7d-b7d7-8338ab3dd376", "name": "777e7565-5332-4b34-962b-6a3114ca9330_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "900c9dcb-6b50-42ef-b05e-f4269e808dc3", "name": "ff4eb721-cb89-4c0e-8201-228b68fcbabe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "de0e49fe-3bdc-4a7d-b7d7-8338ab3dd376"}}}]}, {"uuid": "2706875b-9294-4ba4-bf0e-031c0118dbcc", "name": "load_p1rlv13625_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c667408-52a0-4258-8e93-557c94520a1e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "900c9dcb-6b50-42ef-b05e-f4269e808dc3"}}}}, {"uuid": "3ca686af-a312-424b-ad0a-a2857bea5608", "name": "da0f3f06-1012-4b11-b775-12810257b6b1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dbf022ae-cc92-42fb-80a6-57b5f4af35c9", "name": "e78818ab-c2d2-45d7-8e49-4178d541aa87", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3ca686af-a312-424b-ad0a-a2857bea5608"}}}]}, {"uuid": "3f8f8afb-ed05-41b4-b003-9dbd2533152e", "name": "load_p1rlv13625_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c667408-52a0-4258-8e93-557c94520a1e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dbf022ae-cc92-42fb-80a6-57b5f4af35c9"}}}}, {"uuid": "b5b8ebb5-3bad-4a3e-9274-6b3fe9628924", "name": "0d3c68fa-98b9-4457-9623-b2ddbef6bad9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2167250892906645, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5534364726692191, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "495030ab-3b27-4d33-b025-282b4b044338", "name": "2b498706-f03c-4f51-be0e-276bb22b8961", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5b8ebb5-3bad-4a3e-9274-6b3fe9628924"}}}]}, {"uuid": "56acabce-8878-49c1-b94c-af9220f4e454", "name": "load_p1rlv13626_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aeea20e0-9908-4f28-aa5d-068244e3861b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "495030ab-3b27-4d33-b025-282b4b044338"}}}}, {"uuid": "60e32a94-a8bc-42dd-8a92-eba24c87b680", "name": "b56423f4-655b-404a-9ed5-c661669886fd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2167250892906645, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5534364726692191, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1d65980a-33fe-4dfd-9088-9855d7e3a557", "name": "6243df8a-9e5d-47cb-b112-436fe69e32bd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "60e32a94-a8bc-42dd-8a92-eba24c87b680"}}}]}, {"uuid": "94ea13bc-304f-49d4-84d0-97ddf66b1fba", "name": "load_p1rlv13626_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aeea20e0-9908-4f28-aa5d-068244e3861b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1d65980a-33fe-4dfd-9088-9855d7e3a557"}}}}, {"uuid": "2ebe26fa-10b8-4996-a592-cf2d510877fc", "name": "fd6b2f83-f55c-4178-84d4-25f825f42afc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "29d57d91-dfb5-45cd-8116-2ed75b39201d", "name": "b9a16346-3061-4545-8663-f33e340b22b3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2ebe26fa-10b8-4996-a592-cf2d510877fc"}}}]}, {"uuid": "a9f67b6f-8541-4045-be0d-ac8ec292b43e", "name": "load_p1rlv13627_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bd69c55-2141-4c8e-becf-efa4bff8a63e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "29d57d91-dfb5-45cd-8116-2ed75b39201d"}}}}, {"uuid": "d390e1cb-6ad3-4c4e-8727-81af1319dbf9", "name": "e001b741-a080-4706-be40-76b9d706fd05_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aaccb708-0a7f-4541-9e29-2794fd6b3222", "name": "689efcce-d483-476d-8917-ae96f946d395", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d390e1cb-6ad3-4c4e-8727-81af1319dbf9"}}}]}, {"uuid": "1fe6206e-10f8-4593-a6d9-66b3a1e11005", "name": "load_p1rlv13627_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bd69c55-2141-4c8e-becf-efa4bff8a63e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aaccb708-0a7f-4541-9e29-2794fd6b3222"}}}}, {"uuid": "5502d664-87dc-4e88-928a-98ea7b6e2f1c", "name": "c876f41e-35b4-4931-9d0b-d9c056f9e7cf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6027984746974515, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12293402966163972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "83b5da43-aa46-4ca2-b714-e3e8d4d9aaa9", "name": "2d19e5a5-a6ec-41e1-82d1-d8affbe0489e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5502d664-87dc-4e88-928a-98ea7b6e2f1c"}}}]}, {"uuid": "f69095ba-372d-4810-8411-694971f43d18", "name": "load_p1rlv13628_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e47df44a-79f1-423b-a295-c9c354795895"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "83b5da43-aa46-4ca2-b714-e3e8d4d9aaa9"}}}}, {"uuid": "03010734-757c-40c6-8d5b-a9ba3e866412", "name": "c2fbd6ce-63a8-45aa-9508-6fc3cd17844f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6027984746974515, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12293402966163972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "28f34706-c5c5-47c0-8346-6aa590cb993d", "name": "f1053a09-9888-4e41-9153-fdb1d0b05c4b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "03010734-757c-40c6-8d5b-a9ba3e866412"}}}]}, {"uuid": "79aedce6-a8bc-4f93-b31b-189b72b22de8", "name": "load_p1rlv13628_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e47df44a-79f1-423b-a295-c9c354795895"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "28f34706-c5c5-47c0-8346-6aa590cb993d"}}}}, {"uuid": "00ece0df-1a03-4625-9c72-a0ca6a712f83", "name": "4e76d46b-b0e8-436f-9961-83e68ced5a03_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b240055e-61a7-4a40-8728-b15c9c4e3528", "name": "6954db8d-9915-4086-89b0-dd442cd5b3cb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "00ece0df-1a03-4625-9c72-a0ca6a712f83"}}}]}, {"uuid": "56bffc71-20a4-4d90-8fff-3853b9736046", "name": "load_p1rlv13629_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b4358536-b06f-486d-b336-3a8576b428d0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b240055e-61a7-4a40-8728-b15c9c4e3528"}}}}, {"uuid": "b5346d4f-4346-47c1-ad51-489a5fc3e057", "name": "ee48d810-87be-476c-b6e6-fde84b05eff7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4a16f94c-68e7-4d9b-a619-fb3c0c6948e1", "name": "a7574a04-fc39-4357-9ec9-540175bf69c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5346d4f-4346-47c1-ad51-489a5fc3e057"}}}]}, {"uuid": "d512e023-534b-4887-8712-d2b367fd903e", "name": "load_p1rlv13629_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b4358536-b06f-486d-b336-3a8576b428d0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4a16f94c-68e7-4d9b-a619-fb3c0c6948e1"}}}}, {"uuid": "db5ab1aa-2d9c-4125-94ab-3823975c45a3", "name": "44d7417b-8f31-4b33-a119-6accec609369_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.501244965400895, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7307193315393806, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d7b6bd43-b473-493b-bf4f-e32b4826ed05", "name": "cee0d6e8-87e3-4fd9-b102-fbbf8d850eb5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "db5ab1aa-2d9c-4125-94ab-3823975c45a3"}}}]}, {"uuid": "2af4f9b5-566b-464a-89b4-4f17c9947451", "name": "load_p1rlv13630_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f474e4ba-6300-4014-afe9-c245e08cf3c5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d7b6bd43-b473-493b-bf4f-e32b4826ed05"}}}}, {"uuid": "699807f1-fae9-44bc-88b0-f349cb4bed56", "name": "221e650d-7f9e-4569-b6d8-d9725b7f3b9d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.501244965400895, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7307193315393806, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "19f39d00-78bc-4894-a883-664fbe549f75", "name": "1bbe9954-28bc-42a3-9d62-ef25f2d9ce00", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "699807f1-fae9-44bc-88b0-f349cb4bed56"}}}]}, {"uuid": "e8373eda-07bd-4a9d-acc2-aa85eef3e840", "name": "load_p1rlv13630_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f474e4ba-6300-4014-afe9-c245e08cf3c5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "19f39d00-78bc-4894-a883-664fbe549f75"}}}}, {"uuid": "e3c35c21-d745-4909-889f-6bff9dea666a", "name": "8996a840-c56b-4244-a5bd-a936ab7e4f43_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7837050665512109, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.44874911637056014, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5ca7329c-2183-473b-95a9-77f2be94a3ca", "name": "0944f457-4c1a-46bc-b7c0-8ca6b1c791ce", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e3c35c21-d745-4909-889f-6bff9dea666a"}}}]}, {"uuid": "0a898f62-ea5c-418a-acc7-02c3c134dc37", "name": "load_p1rlv13631_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6015a810-79da-480f-b1a1-fd6a4abdba37"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5ca7329c-2183-473b-95a9-77f2be94a3ca"}}}}, {"uuid": "68c8d2e9-bf41-4d52-b183-24dae14b5724", "name": "248fdd00-1485-49b2-9fa5-142adc189657_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7837050665512109, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.44874911637056014, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b92698dc-2935-4f96-a813-b16d1e060ed2", "name": "1c437de2-b58b-4c30-af12-93c0d6925bcd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "68c8d2e9-bf41-4d52-b183-24dae14b5724"}}}]}, {"uuid": "91760696-f2be-4ed0-8a50-98d918418a84", "name": "load_p1rlv13631_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6015a810-79da-480f-b1a1-fd6a4abdba37"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b92698dc-2935-4f96-a813-b16d1e060ed2"}}}}, {"uuid": "625c002a-2b35-4e06-b117-f555d3def42e", "name": "05f7d4e7-22f5-4b84-ab66-ce7cc8d7b3fd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.008167500419157, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.871384812064858, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aae35308-2937-4f39-993b-ca2d5432f45b", "name": "0a7ea9ae-5600-43f7-aa3d-735141c55119", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "625c002a-2b35-4e06-b117-f555d3def42e"}}}]}, {"uuid": "d4468576-026b-47a1-ae83-e2a50b6701c7", "name": "load_p1rlv13632_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b712121-d0c2-488a-9224-bea72928796f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aae35308-2937-4f39-993b-ca2d5432f45b"}}}}, {"uuid": "85454153-f482-43f0-9863-54d33d19ad67", "name": "806f51fe-a83c-42ca-9771-481c667cb9fd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.008167500419157, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.871384812064858, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c5fb0cff-fe68-4ed9-b59f-4c1190ab0bf5", "name": "c5b13880-b54d-4f04-99cb-1632c874ae4a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "85454153-f482-43f0-9863-54d33d19ad67"}}}]}, {"uuid": "d2cb09f8-4845-4eb7-952d-96a7ea7bd35b", "name": "load_p1rlv13632_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b712121-d0c2-488a-9224-bea72928796f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c5fb0cff-fe68-4ed9-b59f-4c1190ab0bf5"}}}}, {"uuid": "4c650d9a-e789-4024-b747-a4f9b23a6fcb", "name": "c444ea98-6fdd-40da-bcdb-076334c4a3c8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4201171911594663, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7913664471178815, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7ddcbf16-7aee-400a-867b-1625d9b2aae7", "name": "e682a673-e790-4b62-937b-bbd1709020ea", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4c650d9a-e789-4024-b747-a4f9b23a6fcb"}}}]}, {"uuid": "a24f56d6-69d9-4acf-adf0-a7c175597c41", "name": "load_p1rlv13633_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b3fe33f-fdcf-42f5-be08-8da15a4d4958"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7ddcbf16-7aee-400a-867b-1625d9b2aae7"}}}}, {"uuid": "97c7df5d-7d20-4f19-a8df-ff4d27029248", "name": "919b3572-0eda-41a4-a30b-d2ebdca56740_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4201171911594663, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7913664471178815, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7d65b2fe-e861-403c-aacd-ff1a8c6f452e", "name": "2528e6e0-563d-4ad3-aef0-30576fc5cb62", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "97c7df5d-7d20-4f19-a8df-ff4d27029248"}}}]}, {"uuid": "c293303e-86dc-4b84-8db2-eedc97de8c50", "name": "load_p1rlv13633_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b3fe33f-fdcf-42f5-be08-8da15a4d4958"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7d65b2fe-e861-403c-aacd-ff1a8c6f452e"}}}}, {"uuid": "09ccac70-d664-460f-b367-a6828d226496", "name": "67a46fb3-067e-4411-9ca2-215ad98086df_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0491915565570302, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1506537762556939, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a9167dd0-eec4-4187-8d69-1b16829d38bb", "name": "0bcb7770-1b34-4ff2-a46b-7ab95042a64a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "09ccac70-d664-460f-b367-a6828d226496"}}}]}, {"uuid": "4174bb0a-452a-46f0-b4e9-42e67e6fb9f1", "name": "load_p1rlv13634_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "987b05d5-9bb9-434d-98b3-623ee5014870"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a9167dd0-eec4-4187-8d69-1b16829d38bb"}}}}, {"uuid": "a60ff0c5-8c9e-4430-bbe3-e61a9c4b32a2", "name": "a3ef54f3-b048-4cf2-b05c-35382e96d908_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0491915565570302, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1506537762556939, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bd28c65e-c687-47b6-afd7-6bd5a68ec166", "name": "461fcc9c-2fd7-4eab-9c4d-c95afcb50ac7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a60ff0c5-8c9e-4430-bbe3-e61a9c4b32a2"}}}]}, {"uuid": "fda346e7-2464-4bd6-8a0c-8e34f4705a79", "name": "load_p1rlv13634_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "987b05d5-9bb9-434d-98b3-623ee5014870"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bd28c65e-c687-47b6-afd7-6bd5a68ec166"}}}}, {"uuid": "03501c13-ff46-45d2-862c-55d026d69060", "name": "fa7fa910-1b72-44d2-88c9-2c5d4f2160ff_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.31125911334339, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6469035988597648, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "99b34702-aefb-4ecf-9662-efca449d746a", "name": "61b45131-846f-46d6-9521-ecd7655136f7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "03501c13-ff46-45d2-862c-55d026d69060"}}}]}, {"uuid": "2a209559-4d1c-4f42-9a45-244995b2999e", "name": "load_p1rlv13635_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc33013a-6a90-46a7-9127-f32288111c14"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "99b34702-aefb-4ecf-9662-efca449d746a"}}}}, {"uuid": "44aa3bec-ea60-44c4-844a-2e34f39d5b9d", "name": "d29dc4e2-aa32-48e4-831a-60e96c6c3418_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.31125911334339, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6469035988597648, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e2c7b5ec-90a9-45c2-bebe-68f2d9cf2fdf", "name": "ceecdb9d-06d8-43cb-8edc-f252113ff87f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "44aa3bec-ea60-44c4-844a-2e34f39d5b9d"}}}]}, {"uuid": "a846042f-a399-4b23-88b5-28a16125f77f", "name": "load_p1rlv13635_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc33013a-6a90-46a7-9127-f32288111c14"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e2c7b5ec-90a9-45c2-bebe-68f2d9cf2fdf"}}}}, {"uuid": "71f32ea8-d8a0-4783-b914-d623b778fdc7", "name": "e316d186-53a6-4f1c-9669-1116390b9f54_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d1ea5d58-0f18-4498-82c6-9d28a73a51a3", "name": "8ae641c4-13c7-49ad-937c-d462cbf99050", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "71f32ea8-d8a0-4783-b914-d623b778fdc7"}}}]}, {"uuid": "dde7312b-6aa6-4692-91ae-bd663ed25cb0", "name": "load_p1rlv13636_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4d3fe62-b327-4fc6-b2aa-795c9475019a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d1ea5d58-0f18-4498-82c6-9d28a73a51a3"}}}}, {"uuid": "50ebb994-5b3b-45b1-81a3-9101ce95a4ed", "name": "896c2f10-b80d-4849-bac7-9f63bbed8a43_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e70432b1-a134-47c3-b5c5-f7b43d821f3f", "name": "a3f8379e-dbf1-4014-ac38-e848ac421bca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "50ebb994-5b3b-45b1-81a3-9101ce95a4ed"}}}]}, {"uuid": "51241fc7-c76e-4bf9-a2ef-90652f4efae3", "name": "load_p1rlv13636_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4d3fe62-b327-4fc6-b2aa-795c9475019a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e70432b1-a134-47c3-b5c5-f7b43d821f3f"}}}}, {"uuid": "4c46cf04-de7e-4d34-bbfc-5cb180717b6e", "name": "16d6aa2b-a551-495d-af08-1e3622784797_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.942829069048031, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.025560880160820944, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "24d7765a-f07e-4e6b-8a5a-4df51bbf830a", "name": "2e3b5926-fa3e-41d3-bc84-1ba6532ae963", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4c46cf04-de7e-4d34-bbfc-5cb180717b6e"}}}]}, {"uuid": "3e2bd199-1a25-451c-a362-e3b28bbac774", "name": "load_p1rlv13637_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30c470ac-39d1-4379-9ae7-790d912bce2c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "24d7765a-f07e-4e6b-8a5a-4df51bbf830a"}}}}, {"uuid": "6a526513-421e-4dbf-9980-3c77433e854d", "name": "ed201a0a-e610-42cf-a003-a35c43a1cb2b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.942829069048031, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.025560880160820944, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b9cd2d9b-dd5e-4ea7-b10e-746c7a702745", "name": "69434e8b-8305-48f1-a6cb-4c5294aaae7f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6a526513-421e-4dbf-9980-3c77433e854d"}}}]}, {"uuid": "a00fc30c-06aa-41c0-a402-c6f017e5d5fc", "name": "load_p1rlv13637_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30c470ac-39d1-4379-9ae7-790d912bce2c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b9cd2d9b-dd5e-4ea7-b10e-746c7a702745"}}}}, {"uuid": "ad6f4b40-f5a4-47a2-964b-8ce502f3d7dc", "name": "11087ee2-87bd-4257-97dd-3f6eed4c5119_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9149869461814677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5767582022429075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "31e2e4b3-dc1e-466a-8d38-c2eac6c6dd63", "name": "9fcf32bf-adc6-4c44-b307-bd05599604cd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ad6f4b40-f5a4-47a2-964b-8ce502f3d7dc"}}}]}, {"uuid": "a15380e8-2648-4beb-8e30-e530c615396d", "name": "load_p1rlv13638_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db3908f7-94f5-43a7-a3de-1f6c9b72ebd4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "31e2e4b3-dc1e-466a-8d38-c2eac6c6dd63"}}}}, {"uuid": "c53ddde5-2039-402e-980c-16a0f3fdc516", "name": "f3182493-3ea8-4919-807c-2e5cf477f3b3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9149869461814677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5767582022429075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2d627562-5a99-4b97-810f-c0c324d6f7b2", "name": "4858ab75-c396-46a5-b5e9-eaf5f0a5acc5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c53ddde5-2039-402e-980c-16a0f3fdc516"}}}]}, {"uuid": "f767f99c-517e-4293-a22e-558482926470", "name": "load_p1rlv13638_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db3908f7-94f5-43a7-a3de-1f6c9b72ebd4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2d627562-5a99-4b97-810f-c0c324d6f7b2"}}}}, {"uuid": "2819f386-8f44-43b5-9d6c-678d19e3f8d7", "name": "3616b5fe-6980-4925-b3b2-eb27bbe1c497_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fd9ff23c-59b5-463a-b58b-27cdc50735ec", "name": "1c5e5eb7-33b3-4022-aaf7-45d672d8e2c0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2819f386-8f44-43b5-9d6c-678d19e3f8d7"}}}]}, {"uuid": "059d17b4-fe64-4805-bcd9-4e46f9e09235", "name": "load_p1rlv13639_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5484eab0-53a8-471c-92ec-29c11c08e740"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fd9ff23c-59b5-463a-b58b-27cdc50735ec"}}}}, {"uuid": "de1bfb30-3df8-4d09-8f71-222396ce7e69", "name": "0e34e63a-5733-4135-bba1-695543fae735_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f13d4010-6d55-4efe-8655-7521453e11e0", "name": "6210fd61-0848-43e8-9c2e-9c3bf700b9d0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "de1bfb30-3df8-4d09-8f71-222396ce7e69"}}}]}, {"uuid": "4f648b6f-b7e4-43fd-a91e-349c254189ca", "name": "load_p1rlv13639_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5484eab0-53a8-471c-92ec-29c11c08e740"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f13d4010-6d55-4efe-8655-7521453e11e0"}}}}, {"uuid": "ab18cebe-9955-405f-9911-fce8c9913a46", "name": "a471f35b-e72d-47c8-a43d-26e19b81faf7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "35d3008f-4e32-404e-a695-2aa7301c897b", "name": "2be52492-a9d7-4b9f-89e5-d7b666a6aff9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ab18cebe-9955-405f-9911-fce8c9913a46"}}}]}, {"uuid": "d9ba6877-fcb0-40d9-b3cc-e37733bf6458", "name": "load_p1rlv13640_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "653bdc0d-5b21-4640-861b-b88ddb5c651a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "35d3008f-4e32-404e-a695-2aa7301c897b"}}}}, {"uuid": "953924ef-3e84-4553-af18-876f4fe0fd5c", "name": "78c3d82f-a316-4d54-ab96-884224053acc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a3df4cb4-5997-4ca3-b6f5-33fe3f32a2bc", "name": "3b687e1f-5ad4-4334-8641-3a62e52c296d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "953924ef-3e84-4553-af18-876f4fe0fd5c"}}}]}, {"uuid": "98cf1c27-dbb5-4800-89c9-71335ef9faa2", "name": "load_p1rlv13640_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "653bdc0d-5b21-4640-861b-b88ddb5c651a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a3df4cb4-5997-4ca3-b6f5-33fe3f32a2bc"}}}}, {"uuid": "ff2bf355-ab80-4b01-998e-54880051bf9f", "name": "459eab03-c1ca-4265-8a6a-9806f03973e9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.725954562298933, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5866148963219024, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4adc22ee-af0f-46e4-b844-5de2777fadf9", "name": "f391628c-8d56-441e-bfda-3cc31ac49988", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ff2bf355-ab80-4b01-998e-54880051bf9f"}}}]}, {"uuid": "d30fa88e-eabd-48e1-b026-ecd2d7782dfc", "name": "load_p1rlv13641_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eb10938-4b73-406c-bed4-0bd01e0bc20d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4adc22ee-af0f-46e4-b844-5de2777fadf9"}}}}, {"uuid": "69cb7403-840f-440d-8a1a-b06c9aa92f0b", "name": "580fa1fd-d871-413b-a8f9-88bddf9d386a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.725954562298933, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5866148963219024, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82fc3122-1cc5-4744-9415-94b09dbd774f", "name": "8c1a17d5-8cde-4691-abb5-c4ad3ea0e1df", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "69cb7403-840f-440d-8a1a-b06c9aa92f0b"}}}]}, {"uuid": "ea414bd3-b37a-4371-a878-61328ce839fa", "name": "load_p1rlv13641_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eb10938-4b73-406c-bed4-0bd01e0bc20d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "82fc3122-1cc5-4744-9415-94b09dbd774f"}}}}, {"uuid": "d09f2a83-b5c9-4235-8679-a4570d4805f2", "name": "20d07da0-dae0-496c-9ca0-289a628db7bd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2219087879829873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3595087789107823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3831569f-5f73-48f2-a9ab-5a3616063410", "name": "3f700706-7d45-470d-8e42-ada404cb71e3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d09f2a83-b5c9-4235-8679-a4570d4805f2"}}}]}, {"uuid": "34ff9b20-48f4-434c-ad64-8773342da568", "name": "load_p1rlv13642_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "479d1486-ed05-44fa-8fab-64035623f267"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3831569f-5f73-48f2-a9ab-5a3616063410"}}}}, {"uuid": "ac8690af-35ef-4cf7-b728-5df66b0ec6ae", "name": "320e79cb-daa5-4360-97d5-7529918e9f19_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2219087879829873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3595087789107823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a4d6c511-9b88-47d5-9bf8-534ffb5d64a7", "name": "b03c670e-e129-426d-aa5d-d6c19f68019a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ac8690af-35ef-4cf7-b728-5df66b0ec6ae"}}}]}, {"uuid": "870c0741-671e-4fa5-8178-f061a1a30553", "name": "load_p1rlv13642_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "479d1486-ed05-44fa-8fab-64035623f267"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a4d6c511-9b88-47d5-9bf8-534ffb5d64a7"}}}}, {"uuid": "bd325d4d-1161-45e0-a72f-a63d6d594d11", "name": "0118f287-e659-44ea-b124-d4d4f7bd2f1f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0be1befb-4b3d-4ad7-a4af-35cac5f8452c", "name": "7f87bdbe-b5a6-4d42-b7eb-dac0ca68e3e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bd325d4d-1161-45e0-a72f-a63d6d594d11"}}}]}, {"uuid": "5ae8d23c-13f6-490b-bd31-a17c15dfad21", "name": "load_p1rlv13643_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20009de0-cbe7-4b4f-a046-425a6ae71925"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0be1befb-4b3d-4ad7-a4af-35cac5f8452c"}}}}, {"uuid": "c89ef2e0-f868-4dcd-bc19-b27e14951e25", "name": "f557316c-bda0-43e6-a08d-0bce1708c1af_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "393b1cad-6b55-4973-b28a-56692c2e4274", "name": "b9dca927-1456-4f14-a146-5f470c572560", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c89ef2e0-f868-4dcd-bc19-b27e14951e25"}}}]}, {"uuid": "0602d8b5-0a43-4a93-ba8a-e7eff78736a5", "name": "load_p1rlv13643_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20009de0-cbe7-4b4f-a046-425a6ae71925"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "393b1cad-6b55-4973-b28a-56692c2e4274"}}}}, {"uuid": "c1bbb515-b8c7-4c98-87e1-d29e17219acf", "name": "2489afdb-0ac5-4c87-b749-afc4d5c17807_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "45444b45-4777-4dcb-a5b6-a5318dd48642", "name": "95c301f7-5f36-46bb-a632-f91056dfd942", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c1bbb515-b8c7-4c98-87e1-d29e17219acf"}}}]}, {"uuid": "34afd116-cf35-4dee-8632-2c2db844aa7c", "name": "load_p1rlv13645_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1acad56e-b6d6-4fa7-a925-f242c1558eef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "45444b45-4777-4dcb-a5b6-a5318dd48642"}}}}, {"uuid": "729dec84-6190-48e8-8f28-1f1ac1ed1cae", "name": "5f2bf744-bd3e-4593-8c59-6ee59ce6ec97_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "545fd949-ca5f-4021-a9cb-70214da669b1", "name": "8e52d775-cd93-470f-a449-467dd1bd7da5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "729dec84-6190-48e8-8f28-1f1ac1ed1cae"}}}]}, {"uuid": "bab4d514-42f6-48f7-a8f0-3912a1e1a1c8", "name": "load_p1rlv13645_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1acad56e-b6d6-4fa7-a925-f242c1558eef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "545fd949-ca5f-4021-a9cb-70214da669b1"}}}}, {"uuid": "7de9fa63-d7d8-42be-8950-590bc369ae2a", "name": "1d3651b2-1ade-49fb-ab57-a9b07ad20ade_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4519136613739017, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7054970531635038, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c531f4fd-237f-4a4e-b8df-650e5c906732", "name": "956fe972-4e01-481c-84e7-1b6cbfeb7f20", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7de9fa63-d7d8-42be-8950-590bc369ae2a"}}}]}, {"uuid": "5599b81a-cb04-4ba8-95c5-f2ce0818c160", "name": "load_p1rlv13646_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fe0466e-cce5-4c6c-b13f-cedd349b6944"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c531f4fd-237f-4a4e-b8df-650e5c906732"}}}}, {"uuid": "d90b4bd1-901f-4ed8-b6c2-18f91fb1fbe0", "name": "288608e5-0375-438e-9815-90b527a03a3c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4519136613739017, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7054970531635038, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "615b821c-a77c-4577-9683-6b35a7e599b8", "name": "27907f11-b1a1-49ea-ac02-b474b0ee1296", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d90b4bd1-901f-4ed8-b6c2-18f91fb1fbe0"}}}]}, {"uuid": "49d1c147-c2e7-4c73-8f8c-c68335fae76f", "name": "load_p1rlv13646_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fe0466e-cce5-4c6c-b13f-cedd349b6944"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "615b821c-a77c-4577-9683-6b35a7e599b8"}}}}, {"uuid": "8ded91d9-819a-41a7-9317-5644c2b21466", "name": "ea7f762c-ce75-4d60-ace7-be83382b67ef_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7813411640480736, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4182052484168413, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "badfcc26-ec8f-4d69-827c-6970fb6fffba", "name": "2a06c444-3e0e-4bed-901f-2fcc499def0b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ded91d9-819a-41a7-9317-5644c2b21466"}}}]}, {"uuid": "a8732407-5084-4d7d-bc08-770676d828cd", "name": "load_p1rlv13647_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8753d37-07f1-45c6-a483-43cbfb6bf107"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "badfcc26-ec8f-4d69-827c-6970fb6fffba"}}}}, {"uuid": "b5e8a61b-47e3-4497-a372-da74225c037d", "name": "698ba49f-a12a-4a1c-a60e-3a4224a3fdf4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7813411640480736, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4182052484168413, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9905e932-f6db-4c5a-9953-3ae517967290", "name": "a8e4cb2a-552f-477b-990a-7d4864067f6b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5e8a61b-47e3-4497-a372-da74225c037d"}}}]}, {"uuid": "929e7d4b-7ca0-420b-a59f-8131acee3c6e", "name": "load_p1rlv13647_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8753d37-07f1-45c6-a483-43cbfb6bf107"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9905e932-f6db-4c5a-9953-3ae517967290"}}}}, {"uuid": "d9f54d7b-c79c-4e40-98df-ea703f5ac70d", "name": "e5c3a58c-b408-4539-89ca-bf1cf35ce61e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1343287185333217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10429894918818222, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "090bd7d6-3f1f-4e27-b141-78a2939dc01f", "name": "01cc5f96-812a-4b61-b1ee-ae944d1e9e2f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d9f54d7b-c79c-4e40-98df-ea703f5ac70d"}}}]}, {"uuid": "655fa1cb-f8f2-445b-8380-e4606ad75131", "name": "load_p1rlv13648_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62a29ac5-7227-43b2-b602-b1189cc93839"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "090bd7d6-3f1f-4e27-b141-78a2939dc01f"}}}}, {"uuid": "8a0039a2-6d46-4a15-89fd-0e48ddfa2026", "name": "13fc6f7a-f857-4fb9-9f1c-3fa2e404205f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1343287185333217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10429894918818222, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "edd294c3-09a4-4f8a-843d-59f0732f18cd", "name": "2de0392e-0063-46cd-873d-8218831e2e65", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a0039a2-6d46-4a15-89fd-0e48ddfa2026"}}}]}, {"uuid": "7f04e3b5-99a3-417b-9ea6-f2daab8d6fe8", "name": "load_p1rlv13648_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62a29ac5-7227-43b2-b602-b1189cc93839"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "edd294c3-09a4-4f8a-843d-59f0732f18cd"}}}}, {"uuid": "c0691bdd-89f2-488e-914c-503562a2c816", "name": "d5241df9-210a-4632-ba1f-31f5903cefa6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "905b259c-5f98-4478-a1d2-fcbedf1ada7e", "name": "03f14100-0af1-4c78-872a-9c54c3c9bdad", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c0691bdd-89f2-488e-914c-503562a2c816"}}}]}, {"uuid": "274e8dac-f955-4b5d-877d-34b969f045d4", "name": "load_p1rlv13649_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43867e2f-79ee-4cec-bed3-0cad0727118c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "905b259c-5f98-4478-a1d2-fcbedf1ada7e"}}}}, {"uuid": "adf27202-e69a-467a-9e93-2b422c27b8f5", "name": "b86a783e-92c5-4b8b-8f04-8de9193fa62b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b7b902de-dea3-4126-ab0b-8d5a36d63c29", "name": "03e22a3c-06dd-436a-a577-32b9e21ca18c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "adf27202-e69a-467a-9e93-2b422c27b8f5"}}}]}, {"uuid": "06d40c7c-d7d4-443a-b8aa-91d579b4708f", "name": "load_p1rlv13649_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43867e2f-79ee-4cec-bed3-0cad0727118c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b7b902de-dea3-4126-ab0b-8d5a36d63c29"}}}}, {"uuid": "d7d5af8b-daf2-4e4e-9b0d-ed795ed513cc", "name": "658f477d-eaba-4943-a7ee-2a81555af2a2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2570744264864886, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.02246974709606756, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bc03626c-630c-437c-81dd-3315b3978341", "name": "48a360e8-d80c-47b5-b6ba-5ff066efe523", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d7d5af8b-daf2-4e4e-9b0d-ed795ed513cc"}}}]}, {"uuid": "e539658e-9b51-4f32-8034-dfd8818aab1c", "name": "load_p1rlv13650_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fa2041e-34c4-4f1f-a329-74969c3da75f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bc03626c-630c-437c-81dd-3315b3978341"}}}}, {"uuid": "f6a3c7a8-3d24-4f7b-b91c-cb9c3f0b4f3f", "name": "e9d2125e-d841-4d9e-9531-0deabe5a9e78_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2570744264864886, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.02246974709606756, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d0336c96-d254-48cb-a8ab-5ca8ee4e509a", "name": "f759eb0e-e52e-4935-8183-af965777f183", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f6a3c7a8-3d24-4f7b-b91c-cb9c3f0b4f3f"}}}]}, {"uuid": "21214c31-8a2f-45c9-91dd-98abd124759a", "name": "load_p1rlv13650_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fa2041e-34c4-4f1f-a329-74969c3da75f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d0336c96-d254-48cb-a8ab-5ca8ee4e509a"}}}}, {"uuid": "dced574f-ef99-4a2b-ad7a-a26535c32b88", "name": "bed9e268-e4a4-4f24-85be-f266452ffd30_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d0c5d89c-bf53-4014-9e6c-fa9efe4580a4", "name": "4ef69988-cd3c-42a1-a5d2-6cddc8fe53ce", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dced574f-ef99-4a2b-ad7a-a26535c32b88"}}}]}, {"uuid": "4408d259-bb84-44ec-b02f-067428660b1d", "name": "load_p1rlv13651_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c808261e-a49e-4954-bdc4-a8b63d0ee25b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d0c5d89c-bf53-4014-9e6c-fa9efe4580a4"}}}}, {"uuid": "d1fc4eeb-9cc6-4172-b6d4-7289ca5ec624", "name": "a178b7f7-d214-4e92-b211-dec0140ceedb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4aa2831b-6bb2-4cc4-b21f-c46883712692", "name": "e7ae22a7-1090-4452-b54d-fd3f31d49079", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d1fc4eeb-9cc6-4172-b6d4-7289ca5ec624"}}}]}, {"uuid": "373dc048-2ea4-417c-8487-61c88a796053", "name": "load_p1rlv13651_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c808261e-a49e-4954-bdc4-a8b63d0ee25b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4aa2831b-6bb2-4cc4-b21f-c46883712692"}}}}, {"uuid": "69dfdb76-e6ee-4abd-9f38-d45756695404", "name": "36741a16-86b3-44a9-a284-dc5f6ede04b7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9eb220af-0b1b-474d-8a61-2dc6f753fbc0", "name": "ad9f0501-1f15-475c-ada7-35b8c17f18d2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "69dfdb76-e6ee-4abd-9f38-d45756695404"}}}]}, {"uuid": "e3181116-934c-4c25-bd6e-f1e06020124d", "name": "load_p1rlv13652_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3310c14a-d1ee-4d0c-8428-d002703c61d5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9eb220af-0b1b-474d-8a61-2dc6f753fbc0"}}}}, {"uuid": "b2c54594-b1f9-4654-a1b7-420fb0dc3ecf", "name": "62d8c279-f33b-48e5-a06f-2b23ab118224_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2f905575-f631-4ca9-b41d-5ee46496fbfb", "name": "a4c287e9-487e-469e-90ae-cc3f25dee8a0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b2c54594-b1f9-4654-a1b7-420fb0dc3ecf"}}}]}, {"uuid": "e4a891ed-1399-4dae-bb21-1c5fd0c3f2ff", "name": "load_p1rlv13652_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3310c14a-d1ee-4d0c-8428-d002703c61d5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2f905575-f631-4ca9-b41d-5ee46496fbfb"}}}}, {"uuid": "e8bc5267-78dd-4572-b99c-9781edf1a03b", "name": "79722852-e477-4e90-bf4d-de348b8f8c31_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "304e5081-f254-4df0-aae5-f92b694735e8", "name": "9c23987e-3fbd-447d-900b-dd0b801ca8c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e8bc5267-78dd-4572-b99c-9781edf1a03b"}}}]}, {"uuid": "604756e6-8f23-42e6-8335-c7165a48f07b", "name": "load_p1rlv13653_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c61a243-7736-46a0-a950-7cc811381158"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "304e5081-f254-4df0-aae5-f92b694735e8"}}}}, {"uuid": "95b6cfff-b677-446f-8b23-227e177a695b", "name": "48a93325-7a1d-4671-8fae-2adbe2094009_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "70026483-7529-4ffe-8f3b-b6cae4805814", "name": "4e95a876-9d1b-41a0-865f-9347f0ce019a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "95b6cfff-b677-446f-8b23-227e177a695b"}}}]}, {"uuid": "cacbe185-64b6-4e12-b4d8-3d92da57d657", "name": "load_p1rlv13653_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c61a243-7736-46a0-a950-7cc811381158"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "70026483-7529-4ffe-8f3b-b6cae4805814"}}}}, {"uuid": "4215e0af-da77-4d2e-a0be-8d321ac4f6d0", "name": "7ff3ae74-0d5b-45c6-b5dd-9a103a883b8c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82b2e12e-7a54-461c-9aeb-a222f058ec8e", "name": "8a57889c-3821-45cc-9438-a0a84fa702c4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4215e0af-da77-4d2e-a0be-8d321ac4f6d0"}}}]}, {"uuid": "b972ad59-d151-468c-bbd8-0fe62c96767f", "name": "load_p1rlv13654_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7be734c-88e2-42c1-8061-f4632bd05759"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "82b2e12e-7a54-461c-9aeb-a222f058ec8e"}}}}, {"uuid": "e3fd7e6b-3be9-468b-bb42-7a08e9ec8e27", "name": "e67ffab9-dfac-41eb-bbf4-9ebff2f3e456_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1fc8c2fb-8515-4441-b436-ab518d71744e", "name": "cb0ab9b6-7b48-4770-9f04-f90333d35c5e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e3fd7e6b-3be9-468b-bb42-7a08e9ec8e27"}}}]}, {"uuid": "d10b8868-8b0b-47ff-be2a-454a09676e6b", "name": "load_p1rlv13654_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7be734c-88e2-42c1-8061-f4632bd05759"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1fc8c2fb-8515-4441-b436-ab518d71744e"}}}}, {"uuid": "56b5f355-041e-4dba-ba09-03809c3c5b2e", "name": "a40afe02-c157-4c26-9cf8-bd7fa2dd4dd2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6323867069620042, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.40255171211713736, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "baeaae15-0168-4ba2-837d-7809208f82e6", "name": "7dd8ae54-e6f6-436b-a88f-4802f0aee048", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "56b5f355-041e-4dba-ba09-03809c3c5b2e"}}}]}, {"uuid": "349940a9-30e6-4bcf-b4ea-7dc077419d78", "name": "load_p1rlv13656_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8c0a04e-6e22-4da5-9907-7ae8097deb10"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "baeaae15-0168-4ba2-837d-7809208f82e6"}}}}, {"uuid": "b952e3d4-9a7c-40a3-9164-9d0dd955044a", "name": "8dc31abf-deda-4dfa-b7bf-e8f0ac40e338_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6323867069620042, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.40255171211713736, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c0c3b87a-70c4-4b94-b70b-f055b01e00b8", "name": "7196cb5a-f515-4eb5-aa7d-88db8da976a5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b952e3d4-9a7c-40a3-9164-9d0dd955044a"}}}]}, {"uuid": "37c16384-4d78-48e7-881c-0d1f7e0836e3", "name": "load_p1rlv13656_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8c0a04e-6e22-4da5-9907-7ae8097deb10"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c0c3b87a-70c4-4b94-b70b-f055b01e00b8"}}}}, {"uuid": "1f18b628-04c5-4373-aba7-c517e5f25cfd", "name": "286482c8-f090-4cae-8a2e-a73d7db99feb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3136780250521567, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6274781256964336, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "81b85d52-3498-43a8-936c-0438a3a1e77a", "name": "624e03d2-a2a3-40e9-a4ce-1cb0baf735ec", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1f18b628-04c5-4373-aba7-c517e5f25cfd"}}}]}, {"uuid": "65dd228a-3e18-4462-8f6e-0b8ef359f3c7", "name": "load_p1rlv13659_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "122e0772-7de6-4117-b1d3-caafbbbc8e22"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "81b85d52-3498-43a8-936c-0438a3a1e77a"}}}}, {"uuid": "4a0d6619-6653-4170-94df-7f94241e7756", "name": "e731fb7a-2aac-4405-9829-9a124878e978_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3136780250521567, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6274781256964336, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a9b8aef4-770c-4605-91fb-cf5f65bac8ad", "name": "cc3f61f1-61e1-4095-be99-dd251406fe77", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4a0d6619-6653-4170-94df-7f94241e7756"}}}]}, {"uuid": "869b76e9-b831-42f3-8bfe-4034fcee94b6", "name": "load_p1rlv13659_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "122e0772-7de6-4117-b1d3-caafbbbc8e22"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a9b8aef4-770c-4605-91fb-cf5f65bac8ad"}}}}, {"uuid": "1e3a44b0-0311-4a0a-920f-31d3cb8071ea", "name": "a6035deb-21e9-40d2-b1e3-5a81cf2ca1fa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.451252731053624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.713074208581691, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a7a72458-f0a7-4e0f-bab5-35516828e6fa", "name": "05101890-58cb-4a6a-998d-7a80d1a38c47", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1e3a44b0-0311-4a0a-920f-31d3cb8071ea"}}}]}, {"uuid": "aa4f58db-b7d9-429e-a7b8-d50bf374567d", "name": "load_p1rlv13660_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3d6fd13-2f04-4f23-97a3-cdf99159174c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a7a72458-f0a7-4e0f-bab5-35516828e6fa"}}}}, {"uuid": "f7ac0d69-63e9-40a3-81c8-4d9210203563", "name": "68272a3f-b73a-49ac-b04a-74e14740c79c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.451252731053624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.713074208581691, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b2a24286-1b0d-43bd-afe4-9a13c48cf1dd", "name": "9722d5dd-1118-4ef5-be44-6db735db2110", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f7ac0d69-63e9-40a3-81c8-4d9210203563"}}}]}, {"uuid": "d8533016-a154-475b-ae9b-fe6c0e150256", "name": "load_p1rlv13660_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3d6fd13-2f04-4f23-97a3-cdf99159174c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b2a24286-1b0d-43bd-afe4-9a13c48cf1dd"}}}}, {"uuid": "49b8597a-96da-4788-9afb-f420e2d395d7", "name": "f0537617-b121-403f-ba70-6877fc568219_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "16d19764-29c0-4188-95fd-b5ccbb16d11f", "name": "2e81f190-f3c8-4018-9677-fd85b083ba16", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "49b8597a-96da-4788-9afb-f420e2d395d7"}}}]}, {"uuid": "fd271e1a-15aa-4d19-ac28-1921b1f5a1a5", "name": "load_p1rlv13661_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ef8e6ec-86d3-429c-89b4-6c7260701e70"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "16d19764-29c0-4188-95fd-b5ccbb16d11f"}}}}, {"uuid": "6ee4c0dc-6e94-42a4-883c-00fe63e6c34a", "name": "758a5607-2d31-45ef-b75f-52aed25d24fd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ff2dc44d-7d99-4780-9681-ce8f29bd282b", "name": "0eefbf1a-f69c-4f42-a699-ea939db89f8c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6ee4c0dc-6e94-42a4-883c-00fe63e6c34a"}}}]}, {"uuid": "a56c3c6c-7ab4-4461-850f-b48a81dc968d", "name": "load_p1rlv13661_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ef8e6ec-86d3-429c-89b4-6c7260701e70"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ff2dc44d-7d99-4780-9681-ce8f29bd282b"}}}}, {"uuid": "f8133e03-31d5-42d7-bd88-4cc213bcb5b7", "name": "0ba1e3ee-b48a-4b3d-b892-f58040d5479b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2219087879829873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3595087789107823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "df9dad07-8131-40cb-9a8f-064c58479727", "name": "2f22329d-168a-44bd-9637-93fb93b0ccc0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8133e03-31d5-42d7-bd88-4cc213bcb5b7"}}}]}, {"uuid": "14568d59-4779-4b82-bd4c-7d6f84a4677a", "name": "load_p1rlv13662_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e55b944-ffad-47bf-8348-799afa4c7a1d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "df9dad07-8131-40cb-9a8f-064c58479727"}}}}, {"uuid": "50e89d97-6a00-4d85-8890-0efccc86d1d6", "name": "2fad6a38-3c6a-498d-9e60-183787ca00b4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2219087879829873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3595087789107823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4980cbef-343f-4f1c-8a0c-b1bb4d46f7a8", "name": "888f46ed-ff0c-4187-a262-a4883c066470", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "50e89d97-6a00-4d85-8890-0efccc86d1d6"}}}]}, {"uuid": "99b31d76-0371-49fb-aee3-ea5f640aca86", "name": "load_p1rlv13662_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e55b944-ffad-47bf-8348-799afa4c7a1d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4980cbef-343f-4f1c-8a0c-b1bb4d46f7a8"}}}}, {"uuid": "35f09a5f-e76d-4143-a0a1-6b6528905ecf", "name": "e92bb2ae-6b5b-4423-90a4-55f00d52ee1d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4037437915385973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5086059213404144, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c6cf5817-c9e9-42bd-8fa8-1d2f0deb9b7a", "name": "e9e871ed-52e9-4ea3-a1e7-ee2dce5ddc1d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "35f09a5f-e76d-4143-a0a1-6b6528905ecf"}}}]}, {"uuid": "69ddfb6d-3d94-4dab-81e2-68581c898457", "name": "load_p1rlv13663_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54887ca7-ae23-42d0-a715-aed8baa38ade"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c6cf5817-c9e9-42bd-8fa8-1d2f0deb9b7a"}}}}, {"uuid": "553e3b41-b83a-479c-9900-962640ead61c", "name": "8fdeee45-7875-4773-939f-6c2eededbcea_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4037437915385973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5086059213404144, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "00a29a22-4c22-47bf-bd3a-c7811900b5c7", "name": "15aea7ce-4acb-45f9-9a2d-6cec7461ff24", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "553e3b41-b83a-479c-9900-962640ead61c"}}}]}, {"uuid": "de470297-775d-41a9-a47c-c5d09e70a32c", "name": "load_p1rlv13663_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54887ca7-ae23-42d0-a715-aed8baa38ade"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "00a29a22-4c22-47bf-bd3a-c7811900b5c7"}}}}, {"uuid": "b93948c1-dbe7-4ace-bdfd-789dc22a235e", "name": "424fbac6-cc35-412a-8694-f8c7ff2dbe5d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.171921265639173, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.29621618517422543, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "370843e6-cc97-4f14-bd5d-71ce37f2fd6d", "name": "da0ddf58-b766-4b91-93f4-ce4eac28b240", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b93948c1-dbe7-4ace-bdfd-789dc22a235e"}}}]}, {"uuid": "f2fcf549-f097-41f8-8ff2-c5cee47e5668", "name": "load_p1rlv13664_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70cf02cc-8f1b-48ab-b9e6-50c3e58ad9ae"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "370843e6-cc97-4f14-bd5d-71ce37f2fd6d"}}}}, {"uuid": "3116d69b-7117-4fd8-b4e9-76d7811456b4", "name": "7fbb6319-51f4-447f-b58e-f3c627cbc17b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.171921265639173, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.29621618517422543, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a81205d-cea1-4b5b-bf2b-ef3f9c494db7", "name": "1681ffde-b20c-43e2-be25-1228adb048cb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3116d69b-7117-4fd8-b4e9-76d7811456b4"}}}]}, {"uuid": "e5513cae-ff8c-4f6a-82a0-f7fe9d4d4983", "name": "load_p1rlv13664_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70cf02cc-8f1b-48ab-b9e6-50c3e58ad9ae"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a81205d-cea1-4b5b-bf2b-ef3f9c494db7"}}}}, {"uuid": "561dd82a-ae45-4f18-b612-97489aafacb7", "name": "0510710f-c864-4bc0-a449-3dd4188e126d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6009666033769583, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.30487867399122176, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "298f4a0a-6d5a-4036-9050-3b41e1d5f3a5", "name": "fa52f6fb-68d6-49a3-a8ed-829fba2b4bfa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "561dd82a-ae45-4f18-b612-97489aafacb7"}}}]}, {"uuid": "f19c4f4e-5559-4646-b2ae-a189dca4a78e", "name": "load_p1rlv13666_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5868c24b-2a58-459b-8650-a6072241aca8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "298f4a0a-6d5a-4036-9050-3b41e1d5f3a5"}}}}, {"uuid": "2d6621c8-2e92-45df-b7e3-67b7c537e629", "name": "68f1ea3e-f95b-4303-b2a6-98908bdf41d3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6009666033769583, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.30487867399122176, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ce9c0f2e-efd6-4773-b074-1efb58ce18f8", "name": "2d068a03-d5cf-44f3-8e39-40e41e6e57b1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2d6621c8-2e92-45df-b7e3-67b7c537e629"}}}]}, {"uuid": "65c1c2bb-7594-4118-8ba2-bbd216d7ea0f", "name": "load_p1rlv13666_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5868c24b-2a58-459b-8650-a6072241aca8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ce9c0f2e-efd6-4773-b074-1efb58ce18f8"}}}}, {"uuid": "06e41b5d-b214-4e44-8975-b0649d93fe60", "name": "59d31c8d-fdd0-46b2-9502-0fd377ff435a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10b6ca4c-b522-4c46-a7f0-743befb358a6", "name": "a202078d-d353-405c-8692-4abd9581de19", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "06e41b5d-b214-4e44-8975-b0649d93fe60"}}}]}, {"uuid": "4f0a7fbd-d525-4b67-b610-ecc4dbc20dee", "name": "load_p1rlv13667_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d6cdd514-204d-4a86-b0f3-a9bc4990a2aa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10b6ca4c-b522-4c46-a7f0-743befb358a6"}}}}, {"uuid": "ac4210ab-7389-4005-a2ef-073ae6873999", "name": "d8bea9da-89f9-4072-860e-9420f53c46e6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e534cee0-6684-4f52-bc0e-6cd84309dc93", "name": "dea8c815-395b-4c6a-899d-054e1a145d92", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ac4210ab-7389-4005-a2ef-073ae6873999"}}}]}, {"uuid": "858e4943-fb33-4590-9ee4-155d15a843e1", "name": "load_p1rlv13667_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d6cdd514-204d-4a86-b0f3-a9bc4990a2aa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e534cee0-6684-4f52-bc0e-6cd84309dc93"}}}}, {"uuid": "c08997c7-db55-40c4-bf71-998de5dc6a71", "name": "9355b24d-6e65-4b80-8e20-c4cf4483930b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.243385388928283, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18185664736822973, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "843280bd-9358-4b99-85d7-c0dd09bf6f7b", "name": "8c70ecf7-eaa5-4b44-adf6-b23c782fbcc0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c08997c7-db55-40c4-bf71-998de5dc6a71"}}}]}, {"uuid": "823f5fdd-d975-4ec1-a4c5-7eb9e943a700", "name": "load_p1rlv13669_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "607d3b54-2cea-476b-afe2-ea40c6c02ddc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "843280bd-9358-4b99-85d7-c0dd09bf6f7b"}}}}, {"uuid": "669b92ac-4005-42e9-989d-1da0b09a1c0d", "name": "c9ff654e-5d95-48b2-9c5d-aaa5f5920f16_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.243385388928283, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18185664736822973, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "13843380-871f-4a44-97d5-19edb10e8cd1", "name": "7857066d-2d99-4610-9671-18cdf4e6d73f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "669b92ac-4005-42e9-989d-1da0b09a1c0d"}}}]}, {"uuid": "42d869a0-9001-4c85-96d5-1bd32d6d9a19", "name": "load_p1rlv13669_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "607d3b54-2cea-476b-afe2-ea40c6c02ddc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "13843380-871f-4a44-97d5-19edb10e8cd1"}}}}, {"uuid": "c824570f-41c3-4658-98ee-b5d38899b6fb", "name": "5420d868-605b-4836-9448-e01ad2898845_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ad43811a-0dce-48b2-8dad-193d26dc5c7e", "name": "94d0f2f7-b64e-4f42-9c92-9cbce5357977", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c824570f-41c3-4658-98ee-b5d38899b6fb"}}}]}, {"uuid": "4eec0c4e-00d7-4bec-949d-5a1648f8cc2e", "name": "load_p1rlv13670_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce53d307-fc73-487a-8f6a-3a0e0787bf79"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ad43811a-0dce-48b2-8dad-193d26dc5c7e"}}}}, {"uuid": "cd9f93af-ec5b-4d27-9244-d0d906a65dca", "name": "ddd68ff7-775d-4432-b32b-67e2f60fa9fa_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fadec189-327c-4c49-9a41-e9f44f088a90", "name": "f30ed151-47fc-40fe-9c37-0b39891ad867", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cd9f93af-ec5b-4d27-9244-d0d906a65dca"}}}]}, {"uuid": "3c0757fe-078a-4f99-9037-7bf31dd78c2c", "name": "load_p1rlv13670_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce53d307-fc73-487a-8f6a-3a0e0787bf79"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fadec189-327c-4c49-9a41-e9f44f088a90"}}}}, {"uuid": "cce1d914-3897-415d-94c9-0bda66e7584b", "name": "a9637591-c10b-4105-8b34-4ea3820ade8e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9288466752414104, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5041700498617779, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "83e11efa-0cb8-4d77-a6fb-48c4441831cd", "name": "c980a120-d7d0-4495-9d41-52fcb27a478c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cce1d914-3897-415d-94c9-0bda66e7584b"}}}]}, {"uuid": "a20a8092-569d-43be-b17c-299bca2d34fb", "name": "load_p1rlv13671_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2f95b8b-190c-4df2-9dd2-daee5efde34b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "83e11efa-0cb8-4d77-a6fb-48c4441831cd"}}}}, {"uuid": "98e84956-76ab-4a79-ac91-0c753fc10395", "name": "4ecc3f34-13d4-49e2-9636-c3822922023a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9288466752414104, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5041700498617779, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "406dfc6a-2106-4f9a-bb1a-e36b1874ac5c", "name": "865d5e0b-db3c-441b-a3ec-9d306b528262", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "98e84956-76ab-4a79-ac91-0c753fc10395"}}}]}, {"uuid": "05cffae3-c68a-4ca1-9c2c-6d472dcac594", "name": "load_p1rlv13671_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2f95b8b-190c-4df2-9dd2-daee5efde34b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "406dfc6a-2106-4f9a-bb1a-e36b1874ac5c"}}}}, {"uuid": "eac080d0-ce9f-4a11-9e89-064e9652e90a", "name": "5c0125ca-ef8b-4355-ad66-e1e6c40caf68_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c6d2010-b22f-4f29-a013-2e6988795d7b", "name": "80d25aa9-7fde-4ccf-a1b1-35cd5fab65b4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eac080d0-ce9f-4a11-9e89-064e9652e90a"}}}]}, {"uuid": "8d4e629f-b47d-4680-be3c-57609d082098", "name": "load_p1rlv13672_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32bec8ad-b312-4502-a2a1-6a4c9b2dd87a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c6d2010-b22f-4f29-a013-2e6988795d7b"}}}}, {"uuid": "029cbe02-f40e-47e9-8a6a-d7387d5abab2", "name": "50f4da33-f660-4b22-bf6b-fe34737078fb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3b0fd302-f287-459a-ae23-7476c857531f", "name": "a26442c2-5ac1-47c4-a2b3-b4ab086af933", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "029cbe02-f40e-47e9-8a6a-d7387d5abab2"}}}]}, {"uuid": "8a1bf579-c074-4fed-986e-85b6783e25cc", "name": "load_p1rlv13672_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32bec8ad-b312-4502-a2a1-6a4c9b2dd87a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3b0fd302-f287-459a-ae23-7476c857531f"}}}}, {"uuid": "693b4667-daea-4e40-bfff-dd1959206f97", "name": "fc721459-308e-4879-bc34-b613e7f7c85c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7935386970404408, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "55f52881-bd1e-4e64-92b8-eebaa9951c1d", "name": "d510a2f4-a1e2-4e21-af2f-a876e4b9c568", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "693b4667-daea-4e40-bfff-dd1959206f97"}}}]}, {"uuid": "e3e6f22c-25bc-4daa-ba19-48a3f4bf03d1", "name": "load_p1rlv13673_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9467d2d3-ad80-4bc7-aa9f-cd6e76494552"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "55f52881-bd1e-4e64-92b8-eebaa9951c1d"}}}}, {"uuid": "8fca9d32-1a27-4937-ab5d-7af131c409a2", "name": "0537dda4-bdba-4b71-b8b6-1d9426ed5389_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7935386970404408, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d8163229-e0c4-41cf-a995-7a616b434812", "name": "2c77a221-82e8-4961-ae91-366e528cbae6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8fca9d32-1a27-4937-ab5d-7af131c409a2"}}}]}, {"uuid": "189e9cc4-5dee-4a05-b818-18d261acbaf3", "name": "load_p1rlv13673_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9467d2d3-ad80-4bc7-aa9f-cd6e76494552"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d8163229-e0c4-41cf-a995-7a616b434812"}}}}, {"uuid": "cdcbb941-fd4c-47f7-99d4-b5833522ee8e", "name": "fcd8614f-b0c9-4179-a0bd-6de5a6d6295a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3711169311548215, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.698133467399761, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a39d1a35-4104-4eed-bd3a-065a7b917b55", "name": "ec8fff74-3bfd-4245-a89b-a6c8db3c0025", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cdcbb941-fd4c-47f7-99d4-b5833522ee8e"}}}]}, {"uuid": "a82d7413-7003-40aa-a574-389c577ecef9", "name": "load_p1rlv13675_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c532e298-bdd5-416e-8ebe-a082489ffee6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a39d1a35-4104-4eed-bd3a-065a7b917b55"}}}}, {"uuid": "f8c09000-4b28-45b6-a38a-de39aa272539", "name": "3bd3720d-ffed-4317-a656-460de94fe06e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3711169311548215, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.698133467399761, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8c8addae-8650-47cd-9563-df844c7de159", "name": "f50d2292-b086-4db1-8466-6afb06457711", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8c09000-4b28-45b6-a38a-de39aa272539"}}}]}, {"uuid": "60ee37ce-bbe8-486f-b6e2-c9b26c754bd1", "name": "load_p1rlv13675_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c532e298-bdd5-416e-8ebe-a082489ffee6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8c8addae-8650-47cd-9563-df844c7de159"}}}}, {"uuid": "0fff1cf9-f15e-4586-b11a-72f58c6f6003", "name": "a98e48cc-d122-4e98-a9c0-1fadf8c53d63_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3cc3a673-8856-4f3b-9c8f-f7daaa17fb65", "name": "cb431138-581d-4918-b0c8-cae906037191", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0fff1cf9-f15e-4586-b11a-72f58c6f6003"}}}]}, {"uuid": "b627c3b4-2b03-4e8f-a8be-61431fb5fd12", "name": "load_p1rlv13676_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8df1a69e-5b18-4eef-ab60-543a97257297"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3cc3a673-8856-4f3b-9c8f-f7daaa17fb65"}}}}, {"uuid": "6a22ceca-21eb-466d-9d9e-c24cc239af5d", "name": "742fed2a-5e6e-4add-9b6b-9ac27249fd3a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a0765586-2c2e-40b8-b1cf-e8c980220f17", "name": "7629d3d9-c942-4811-958e-2bd2ac62601e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6a22ceca-21eb-466d-9d9e-c24cc239af5d"}}}]}, {"uuid": "131c54ad-6996-45ed-96ad-bca519031e12", "name": "load_p1rlv13676_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8df1a69e-5b18-4eef-ab60-543a97257297"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a0765586-2c2e-40b8-b1cf-e8c980220f17"}}}}, {"uuid": "2159daa7-94bc-4a90-b7e3-9380fe01ef2f", "name": "95d4f202-1a21-460c-bb0e-64573f95dc6f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 12.611907582113087, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.885290064059574, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "526c56c3-9921-4fa4-a847-f1aaf7e2bf36", "name": "f0684b75-8c89-4aee-b462-56154d3d838e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2159daa7-94bc-4a90-b7e3-9380fe01ef2f"}}}]}, {"uuid": "38ef36d4-caaa-44ce-822a-172645112c72", "name": "load_p1rlv13677_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9aa7e62-8974-4ef0-aa5a-bcd545245aea"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "526c56c3-9921-4fa4-a847-f1aaf7e2bf36"}}}}, {"uuid": "d47e11d8-d612-4fd1-8682-c3435b00d0fa", "name": "38ec15b0-ee6b-4572-9bfb-3094e633a9c6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 12.611907582113087, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.885290064059574, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5adc2c36-14a6-47ba-8065-699e914c5cac", "name": "7715ca32-ff8b-41d5-b13e-652d37d6fbba", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d47e11d8-d612-4fd1-8682-c3435b00d0fa"}}}]}, {"uuid": "30eb92bc-4c73-40a8-b189-220ec402e1a5", "name": "load_p1rlv13677_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9aa7e62-8974-4ef0-aa5a-bcd545245aea"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5adc2c36-14a6-47ba-8065-699e914c5cac"}}}}, {"uuid": "13171c16-3766-48a6-b85d-fce1b4c23608", "name": "f1180b47-ce6c-459c-83e7-24fe85daf4e6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6b7e05ca-5d8d-4687-9c91-c46be0e94393", "name": "ced260df-4a12-44dd-880b-4d67e0c60293", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "13171c16-3766-48a6-b85d-fce1b4c23608"}}}]}, {"uuid": "b60bbcc8-db1c-4b2c-9ab8-17791087b760", "name": "load_p1rlv13678_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32b75c61-4e97-4e21-a786-8aab7a2d88f8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6b7e05ca-5d8d-4687-9c91-c46be0e94393"}}}}, {"uuid": "b62f2251-d24d-45e7-980e-ef4d9b47a504", "name": "1c1f827a-7066-412b-bf61-608d040d4916_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "56ae25bf-98c2-4005-ac11-543cc9eddeb7", "name": "d22d54e4-5e52-4472-8bf7-9a78ff6df048", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b62f2251-d24d-45e7-980e-ef4d9b47a504"}}}]}, {"uuid": "a0329e2e-1fa6-46e3-824e-c7da00ff962b", "name": "load_p1rlv13678_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32b75c61-4e97-4e21-a786-8aab7a2d88f8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "56ae25bf-98c2-4005-ac11-543cc9eddeb7"}}}}, {"uuid": "1216f196-6d86-4e3b-bda0-7366a867f755", "name": "02fab3ec-855e-490e-896f-7a706d20c1d4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5877230897388055, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4388767979233367, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f958ad87-2a98-4e6a-a293-8057d8fe389f", "name": "91e84414-0314-4efb-aba4-d8fed00ee89e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1216f196-6d86-4e3b-bda0-7366a867f755"}}}]}, {"uuid": "73b7d0ef-ca91-438c-868f-4ce161d78b94", "name": "load_p1rlv13679_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "284bbc5d-bb49-404d-823e-08ec543c90b8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f958ad87-2a98-4e6a-a293-8057d8fe389f"}}}}, {"uuid": "97ce0ac1-19b9-4960-8f86-e49ce43b4fdd", "name": "15a4960a-ad64-43bb-8715-67624839e8bb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5877230897388055, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4388767979233367, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a345b66d-51c6-4718-92d2-1e66017171ec", "name": "646d7312-411e-4fa8-8089-802c3b8ac94a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "97ce0ac1-19b9-4960-8f86-e49ce43b4fdd"}}}]}, {"uuid": "f5ffe810-c070-4042-bd16-a1d1047e555d", "name": "load_p1rlv13679_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "284bbc5d-bb49-404d-823e-08ec543c90b8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a345b66d-51c6-4718-92d2-1e66017171ec"}}}}, {"uuid": "c8b1c45d-d4d0-4928-935c-3866c5267d73", "name": "fc9cbd12-67da-4ddf-9e17-a4cc9d3d7a39_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "90e84820-53f8-4ec5-ab30-c1b8adeba609", "name": "a6367165-e64e-4785-83c4-49e85d650317", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c8b1c45d-d4d0-4928-935c-3866c5267d73"}}}]}, {"uuid": "0fb1c0b4-f597-4755-9070-7a24b5f8b93a", "name": "load_p1rlv13680_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85b910cd-def8-41d8-ad47-3c074a54ad8d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "90e84820-53f8-4ec5-ab30-c1b8adeba609"}}}}, {"uuid": "24e8ad5a-5435-4bd3-a930-36188d2f4313", "name": "0a87ea87-5580-41e4-a52e-41639b7d996c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ea4d6a04-3fdf-4e82-baad-0269aed2b904", "name": "996cd32f-f05e-4470-b8d1-10acdbd6854d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "24e8ad5a-5435-4bd3-a930-36188d2f4313"}}}]}, {"uuid": "21437a63-b495-4b76-876c-e5f86f7be7fc", "name": "load_p1rlv13680_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85b910cd-def8-41d8-ad47-3c074a54ad8d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ea4d6a04-3fdf-4e82-baad-0269aed2b904"}}}}, {"uuid": "6632eb7e-bae8-4711-8280-ac3a0a991206", "name": "28893ff5-412e-40a3-a212-52e2782d34ef_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "000ac7b0-24c3-4950-972d-e20658228342", "name": "8afd517a-a595-4d9f-b888-4b98d003878a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6632eb7e-bae8-4711-8280-ac3a0a991206"}}}]}, {"uuid": "369fe88d-458f-495d-a6fc-e2299dcaa1d3", "name": "load_p1rlv13681_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60f08cde-51d3-4b51-9ab5-b61c8043950f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "000ac7b0-24c3-4950-972d-e20658228342"}}}}, {"uuid": "73ed9a9b-8b1c-4d72-997d-3b3f06174e72", "name": "d307541e-6390-420b-90bc-c354842c8c4e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ad96ba65-d3c8-4412-a032-176eab395487", "name": "6105ce88-9320-477f-b2d2-85e6dd5ad86d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "73ed9a9b-8b1c-4d72-997d-3b3f06174e72"}}}]}, {"uuid": "82b351e5-a3aa-47e2-9520-cc902c46a692", "name": "load_p1rlv13681_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60f08cde-51d3-4b51-9ab5-b61c8043950f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ad96ba65-d3c8-4412-a032-176eab395487"}}}}, {"uuid": "865ddcf7-98d3-41f6-bf38-defee83d97b8", "name": "7ed0c62d-bcff-4b32-a663-d21ae0bf8ac3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5757409771642927, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7652901499575055, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "059b3c81-83a8-4bb0-8f63-a8de9452fb9b", "name": "4fffba48-2ddb-4844-95b5-c2808665038f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "865ddcf7-98d3-41f6-bf38-defee83d97b8"}}}]}, {"uuid": "629d17c4-bebd-48c9-879e-0c0e033ca412", "name": "load_p1rlv13682_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a3c050c-cc0d-460e-af02-ce3421431474"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "059b3c81-83a8-4bb0-8f63-a8de9452fb9b"}}}}, {"uuid": "1295811e-de6a-44ad-a13e-dda7e4e2cf61", "name": "9152cc72-9051-4239-b8f0-9b3dc8e0a72a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5757409771642927, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7652901499575055, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "591fd267-9404-4294-ae61-8c65df29bcb9", "name": "330bb019-c54a-4ecb-a332-7035a124455b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1295811e-de6a-44ad-a13e-dda7e4e2cf61"}}}]}, {"uuid": "47422c8c-3417-4dac-9c86-ffc9609bda7c", "name": "load_p1rlv13682_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a3c050c-cc0d-460e-af02-ce3421431474"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "591fd267-9404-4294-ae61-8c65df29bcb9"}}}}, {"uuid": "0db7c061-169a-4013-b150-b5f93a5140e5", "name": "b70b337e-55a5-4def-a326-eaaf47f57728_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5877230897388055, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4388767979233367, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "872b1bac-ff07-4d30-adf6-317dd41a1de5", "name": "2675fd69-b097-4d9b-9475-e2f3719c7a70", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0db7c061-169a-4013-b150-b5f93a5140e5"}}}]}, {"uuid": "668da774-22b3-42e2-a6b1-0280c9816f6a", "name": "load_p1rlv13683_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "de45dc59-3e0a-4b33-8cf4-d5213b0140c1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "872b1bac-ff07-4d30-adf6-317dd41a1de5"}}}}, {"uuid": "0e2ad523-f99c-4929-8d16-91ef3629506b", "name": "07fbfeaa-dc3a-4b54-b01e-0afb2c1c0371_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5877230897388055, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4388767979233367, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "54c1eeed-950d-4379-b00d-847f964c7ac4", "name": "d63dc4c7-07a6-4451-b606-6641acdcc48a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0e2ad523-f99c-4929-8d16-91ef3629506b"}}}]}, {"uuid": "ee5e2946-2306-4eaa-af5e-901222eea510", "name": "load_p1rlv13683_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "de45dc59-3e0a-4b33-8cf4-d5213b0140c1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "54c1eeed-950d-4379-b00d-847f964c7ac4"}}}}, {"uuid": "aa9fa668-8b5c-4c16-aa75-31f5d381c321", "name": "be235377-0688-4d31-a2cf-c9e6c94bc6e7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5202593896091736, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6973445820856009, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c859be38-862f-42d2-8694-e366a9f2128c", "name": "84e237c2-c2a7-4aa4-b35b-8229b8b5a493", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aa9fa668-8b5c-4c16-aa75-31f5d381c321"}}}]}, {"uuid": "f5fe6a40-9cf3-4744-bef2-05e7f64a97fc", "name": "load_p1rlv13684_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ec49353-14d1-4917-83bc-ca62cd94bf30"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c859be38-862f-42d2-8694-e366a9f2128c"}}}}, {"uuid": "2cd83c37-2373-4eda-af9a-c268cdd40bba", "name": "4b4456a7-c3f4-4a2e-88af-a0635f507705_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5202593896091736, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6973445820856009, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d89384a1-0e1f-41bf-8082-168c05d69b38", "name": "45cc88fb-5813-44e0-b1f4-9cd14a9451bc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2cd83c37-2373-4eda-af9a-c268cdd40bba"}}}]}, {"uuid": "6397bd60-fbca-423c-aaae-fe883c0a045e", "name": "load_p1rlv13684_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ec49353-14d1-4917-83bc-ca62cd94bf30"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d89384a1-0e1f-41bf-8082-168c05d69b38"}}}}, {"uuid": "c1bedbde-cb3b-48cf-83a8-2820a7cbe371", "name": "efdbfcfc-3608-4192-8ee7-1f4bfb75171f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3a9035cd-3ef0-4eb6-a016-ddba363a86a7", "name": "b77753f9-7255-4fa0-8139-9968b8f1520b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c1bedbde-cb3b-48cf-83a8-2820a7cbe371"}}}]}, {"uuid": "19754d34-82fa-46dd-84ee-d2646d6b799d", "name": "load_p1rlv13685_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f777bc74-e6f3-4e80-bb72-0764964db21e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3a9035cd-3ef0-4eb6-a016-ddba363a86a7"}}}}, {"uuid": "71467a1e-1ede-47b9-9bfd-85c4bac34c8f", "name": "4704cf25-87d5-43f7-83d1-c6088b025dd4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "36f533fa-a479-4daa-b3e0-5a2c5dbb51c3", "name": "3006d40c-9556-418a-aab0-e2444e2207a5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "71467a1e-1ede-47b9-9bfd-85c4bac34c8f"}}}]}, {"uuid": "3eabe4a1-6c61-4686-922c-e3a0e40af83e", "name": "load_p1rlv13685_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f777bc74-e6f3-4e80-bb72-0764964db21e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "36f533fa-a479-4daa-b3e0-5a2c5dbb51c3"}}}}, {"uuid": "94e6fa50-42fc-41e9-9abb-201d8e23d94f", "name": "fa86f889-dfcb-41a6-8f73-d9d7d90bf208_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ebee099f-241a-4c7d-b75d-2058d800889d", "name": "a9495890-1185-489f-b8c4-26fb7b1d0232", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "94e6fa50-42fc-41e9-9abb-201d8e23d94f"}}}]}, {"uuid": "91bc007c-1af6-48a0-a5e6-d8f0d37d137e", "name": "load_p1rlv13686_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60fe0a16-aa4d-4fe8-9f39-81bfa13b505f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ebee099f-241a-4c7d-b75d-2058d800889d"}}}}, {"uuid": "1112faee-e8b7-4260-880a-43e211c9ced0", "name": "39a3bdc6-ca82-438b-b699-d645d3ca387a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c9a78a4-19b6-4b48-9b0f-f5d183778f42", "name": "c339dea3-5781-414f-9f68-233cf2e25740", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1112faee-e8b7-4260-880a-43e211c9ced0"}}}]}, {"uuid": "d3c9ea73-77eb-488a-b9c1-b52499a39dba", "name": "load_p1rlv13686_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60fe0a16-aa4d-4fe8-9f39-81bfa13b505f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c9a78a4-19b6-4b48-9b0f-f5d183778f42"}}}}, {"uuid": "0f1e6ac0-70aa-4af0-a939-10d6bcc816b0", "name": "94db7979-8999-44bf-bf37-2b918522fb47_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4786893203254163, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3666592754227633, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8de6b990-1453-4ed8-abf9-d39634ea2aee", "name": "dacc3adb-a90c-4aea-b34a-559baea1c165", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0f1e6ac0-70aa-4af0-a939-10d6bcc816b0"}}}]}, {"uuid": "62d4d493-6a6b-41cd-ba20-e0f18e875b39", "name": "load_p1rlv13687_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4671f981-e26e-4f26-9698-7f9068ce6dec"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8de6b990-1453-4ed8-abf9-d39634ea2aee"}}}}, {"uuid": "332f9759-59a9-4733-84d5-01ddeb74945d", "name": "ab8b8986-c290-4ceb-8151-476952ad0e4f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4786893203254163, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3666592754227633, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "df94fbb6-0cd0-4e7a-8a43-22c6ff208d97", "name": "bc05459c-41f7-465c-a4a3-e1c5fd8cec2a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "332f9759-59a9-4733-84d5-01ddeb74945d"}}}]}, {"uuid": "29645c13-d3d0-4b4c-bbbf-afd5222598a3", "name": "load_p1rlv13687_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4671f981-e26e-4f26-9698-7f9068ce6dec"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "df94fbb6-0cd0-4e7a-8a43-22c6ff208d97"}}}}, {"uuid": "bd4ddb24-8e29-4b96-af3b-96f25a7494de", "name": "1319ad49-c4e4-44ac-9f97-597c74220ab2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7344cd86-6533-4184-a373-c02ab9549fca", "name": "332dc737-3c56-4c9e-bef6-ea2937774ea8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bd4ddb24-8e29-4b96-af3b-96f25a7494de"}}}]}, {"uuid": "4e62be72-5efb-4974-b102-b27fd9db4d5a", "name": "load_p1rlv13689_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e5db11f-0418-4119-9c71-26619456fd7b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7344cd86-6533-4184-a373-c02ab9549fca"}}}}, {"uuid": "5f414c6b-8fd3-4126-bd2a-bb61f3c48abe", "name": "d83021b0-7f17-4b5c-b199-976f49090c11_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "efbe0b52-16e1-4632-9ca6-3f01d3a7c2f6", "name": "4ccaf277-0aec-4dce-bdd6-8036eab4f00f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5f414c6b-8fd3-4126-bd2a-bb61f3c48abe"}}}]}, {"uuid": "392ed64a-44d5-409a-bcb8-7b53d7cb16be", "name": "load_p1rlv13689_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e5db11f-0418-4119-9c71-26619456fd7b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "efbe0b52-16e1-4632-9ca6-3f01d3a7c2f6"}}}}, {"uuid": "3200f720-b710-45ce-9dcf-f6448fe8fb4f", "name": "6f5a230a-2bc8-448d-ad0c-ca40306ac670_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "63d99ad2-499f-4001-8c6b-02d3b68cf97a", "name": "57e7ef2c-f725-4c38-a0d1-37ad2dc3eecf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3200f720-b710-45ce-9dcf-f6448fe8fb4f"}}}]}, {"uuid": "9530d4ad-f493-4ae8-b3f2-3e303d647d75", "name": "load_p1rlv13690_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "71c26ca3-0d61-46b8-a95b-710e0b760b62"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "63d99ad2-499f-4001-8c6b-02d3b68cf97a"}}}}, {"uuid": "7823cc66-5ff2-4c20-ab5d-91512e9d2c41", "name": "833ab35f-38f3-4673-b957-be716b6dcec7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2e2346ec-1d8b-496c-8acb-0feed9154b43", "name": "b15f16e7-cad3-4f3e-ae5f-129f399a4890", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7823cc66-5ff2-4c20-ab5d-91512e9d2c41"}}}]}, {"uuid": "bf76abe8-4b18-41e3-af4e-b76279eb2699", "name": "load_p1rlv13690_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "71c26ca3-0d61-46b8-a95b-710e0b760b62"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2e2346ec-1d8b-496c-8acb-0feed9154b43"}}}}, {"uuid": "e1737a50-5fd7-4b33-870f-d5b087c76427", "name": "fb5a4aa2-45c2-4ab6-9c67-965f1b1d50cb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7ba0cafd-5471-4410-a509-d82014858abd", "name": "ac7f08f8-7179-400f-9966-1643b06fc540", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e1737a50-5fd7-4b33-870f-d5b087c76427"}}}]}, {"uuid": "4b3eeef6-2fdc-4483-9a15-7d8a4f1f2ed0", "name": "load_p1rlv13691_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "850df31b-ee95-4903-93b7-6e5911e8f8a0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7ba0cafd-5471-4410-a509-d82014858abd"}}}}, {"uuid": "2ae22984-622d-4a1d-85f5-ce7064c1ae74", "name": "3cc735fc-385d-43f0-a35a-333df4a3392b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "124668c6-413a-4b80-bdda-2c889f127fc4", "name": "18b11031-e37c-4533-a5ae-8f60821f73cd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2ae22984-622d-4a1d-85f5-ce7064c1ae74"}}}]}, {"uuid": "24ccb9aa-e453-4fad-a5c8-1e8a306ff1eb", "name": "load_p1rlv13691_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "850df31b-ee95-4903-93b7-6e5911e8f8a0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "124668c6-413a-4b80-bdda-2c889f127fc4"}}}}, {"uuid": "3df4c39e-8ae1-4947-b3bc-19df9c776026", "name": "f6f6fdb3-fe43-4c07-8b28-4962430c7165_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.1140699739098325, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.0691290550182753, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9644c026-329a-4a1f-998b-60ece9776419", "name": "1f5df881-3b77-4b4a-bd21-a995d244dd40", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3df4c39e-8ae1-4947-b3bc-19df9c776026"}}}]}, {"uuid": "92ded483-725f-40c6-84b3-98a6015cec71", "name": "load_p1rlv13692_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "091b545a-eb31-4bea-a0a6-5aa9c7a8397f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9644c026-329a-4a1f-998b-60ece9776419"}}}}, {"uuid": "d509bf1b-6112-4ef3-8154-002006554632", "name": "8079b172-9551-4da3-afd7-57c2a2d1d119_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.1140699739098325, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.0691290550182753, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "272b06f6-e51d-4f01-8e44-3e9511586061", "name": "f002eb9c-8fd9-40ef-bda6-b972d6ca4b2b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d509bf1b-6112-4ef3-8154-002006554632"}}}]}, {"uuid": "e1bfcb4c-83c9-4e63-a718-ede158d8b3a9", "name": "load_p1rlv13692_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "091b545a-eb31-4bea-a0a6-5aa9c7a8397f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "272b06f6-e51d-4f01-8e44-3e9511586061"}}}}, {"uuid": "f549d4ee-7d2c-458a-8865-413d3613ff12", "name": "eb9d67ed-dbaf-4e6a-aa5f-36a91f666e0b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e41d8d1c-8dd4-4bf2-a16c-50fca8aa045e", "name": "2830747a-ac37-40dc-8c02-935d3b9912ec", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f549d4ee-7d2c-458a-8865-413d3613ff12"}}}]}, {"uuid": "d55f90b8-e894-4da7-860a-3958326632e3", "name": "load_p1rlv13693_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5815b75-1226-4221-9bcb-bc75ce85fa17"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e41d8d1c-8dd4-4bf2-a16c-50fca8aa045e"}}}}, {"uuid": "476a69e1-a9e0-4928-b7f3-552cc90bf303", "name": "38c60878-bd82-4df7-848f-9985598f5fe7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "655ebaf4-0818-4331-ae7d-7146bedafebc", "name": "1ab0c66e-95fd-4115-80fd-a9db9b12c908", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "476a69e1-a9e0-4928-b7f3-552cc90bf303"}}}]}, {"uuid": "149e6a50-bc4c-437f-9e56-86146effe61a", "name": "load_p1rlv13693_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5815b75-1226-4221-9bcb-bc75ce85fa17"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "655ebaf4-0818-4331-ae7d-7146bedafebc"}}}}, {"uuid": "a62dc22d-1f8d-46b2-8556-ca0dc332c559", "name": "8e6a59bb-fad2-4318-9066-580c5077702b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8bd92f03-a0f4-48ce-9b3d-09bffcd2412d", "name": "6557eb3f-9fea-4473-a24d-7b4ce0e44fc6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a62dc22d-1f8d-46b2-8556-ca0dc332c559"}}}]}, {"uuid": "4a37d94a-f80d-47e0-b65b-01e2960318e1", "name": "load_p1rlv13694_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1de2ebf2-3207-4bf7-9702-4c729d99a6cf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8bd92f03-a0f4-48ce-9b3d-09bffcd2412d"}}}}, {"uuid": "71d8bcb0-42da-4718-bf2d-e7d363ead5c4", "name": "a96590fd-adbb-41d9-a01a-98631e5a4933_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aa9a819d-caee-485b-88bf-f4ae3727b769", "name": "b739da1c-6f92-41cb-81d2-12f6cbf701d1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "71d8bcb0-42da-4718-bf2d-e7d363ead5c4"}}}]}, {"uuid": "9b9c8591-0453-4c68-bf4a-37c70b29ae2f", "name": "load_p1rlv13694_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1de2ebf2-3207-4bf7-9702-4c729d99a6cf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aa9a819d-caee-485b-88bf-f4ae3727b769"}}}}, {"uuid": "09c4d5f1-71c4-469b-8603-f1b25c00d631", "name": "4c485e30-41bd-4083-8717-dbc40101c2f3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.17188390355877, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.554870220420769, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a3ee682c-b1c7-44c4-bff6-a4d8acad378c", "name": "d6029c33-cd14-49e9-888f-548ed4366560", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "09c4d5f1-71c4-469b-8603-f1b25c00d631"}}}]}, {"uuid": "4f0a34ae-c8fc-44bd-9c7c-c804db865c3b", "name": "load_p1rlv13695_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d73963d7-acf4-48b3-8e54-6ee9f403d36f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a3ee682c-b1c7-44c4-bff6-a4d8acad378c"}}}}, {"uuid": "a14f6598-dcf3-4222-aff9-03aa785c3232", "name": "7324e4d5-eff6-4b91-8842-ad45bb36e2fb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.17188390355877, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.554870220420769, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "38fd2fc8-af2c-4375-bb14-2735753fd5ba", "name": "01c38178-5c60-4a27-b3b1-b8c4762989e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a14f6598-dcf3-4222-aff9-03aa785c3232"}}}]}, {"uuid": "ae6c0fd0-d614-4c0f-90ef-5fc0b3295f59", "name": "load_p1rlv13695_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d73963d7-acf4-48b3-8e54-6ee9f403d36f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "38fd2fc8-af2c-4375-bb14-2735753fd5ba"}}}}, {"uuid": "5eb73892-27e2-4054-8588-b0de1be5cdee", "name": "a3430b8f-8606-44be-b936-cc51b83628d6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.170918611307458, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.575413421893771, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e031df21-cbfa-4b1e-8a85-d904674671a8", "name": "a35ed688-1237-412d-8710-5425de3c9f82", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5eb73892-27e2-4054-8588-b0de1be5cdee"}}}]}, {"uuid": "cab9456a-bb12-404e-a3a4-c1d4a783098f", "name": "load_p1rlv13696_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f92273c9-90b8-4819-b036-9d69afb5aed6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e031df21-cbfa-4b1e-8a85-d904674671a8"}}}}, {"uuid": "ae2a96b5-8402-4705-b3ef-47eb2956246d", "name": "aebf8306-45df-47e3-8094-e02d25e14710_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.170918611307458, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.575413421893771, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "545bb6e9-937c-4335-8831-35cbfa5fc324", "name": "b7f7404f-11dd-4e22-8878-ad6ae3c5a2ca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ae2a96b5-8402-4705-b3ef-47eb2956246d"}}}]}, {"uuid": "0125f75c-efd6-4957-8ac0-1e8d533a3b87", "name": "load_p1rlv13696_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f92273c9-90b8-4819-b036-9d69afb5aed6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "545bb6e9-937c-4335-8831-35cbfa5fc324"}}}}, {"uuid": "483eaae2-214c-421b-b39c-b03f28d630fe", "name": "6bfb24b7-09c7-4f6c-a33c-d67aea19d82a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2370181650987906, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5806603708512078, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6e1fad86-4bfd-4d5f-8057-b77f7ec6b87f", "name": "6872893f-2e86-4889-9cf0-3945d3f9b966", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "483eaae2-214c-421b-b39c-b03f28d630fe"}}}]}, {"uuid": "fe5131a4-e117-4bfc-8606-a1410341e010", "name": "load_p1rlv13697_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c808261e-a49e-4954-bdc4-a8b63d0ee25b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6e1fad86-4bfd-4d5f-8057-b77f7ec6b87f"}}}}, {"uuid": "8a9fb659-c0b2-49a0-9cbc-4c1489f3ddbd", "name": "e2f294d7-0cb7-467e-89cf-090a4f35106e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2370181650987906, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5806603708512078, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b6121fa9-05bb-4af6-ace7-6219736b9224", "name": "e6ad07be-0efa-4e50-8ae6-c3e29b1d6a86", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a9fb659-c0b2-49a0-9cbc-4c1489f3ddbd"}}}]}, {"uuid": "05f1dfea-f98f-4ad7-b5f1-125332718265", "name": "load_p1rlv13697_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c808261e-a49e-4954-bdc4-a8b63d0ee25b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b6121fa9-05bb-4af6-ace7-6219736b9224"}}}}, {"uuid": "994053b2-2dcd-4e45-99c1-0143b8d3a3f4", "name": "9633f640-6a82-4afc-8062-185d65b30729_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cac11212-2c59-40b9-a2a9-c754625bb9fe", "name": "38b59a81-9591-40cb-ab35-f1578767f4a6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "994053b2-2dcd-4e45-99c1-0143b8d3a3f4"}}}]}, {"uuid": "cf7355e4-9d2e-4ae6-9384-4cbac3892452", "name": "load_p1rlv13698_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3839c291-3f45-46c3-973f-6a9615fcf81b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cac11212-2c59-40b9-a2a9-c754625bb9fe"}}}}, {"uuid": "48520c39-4eb5-43e5-86ce-ee13fd69508b", "name": "879b2b6d-5a7e-43a3-b01d-cf1172000d71_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1a354e32-b9f7-48a2-9d67-16babb502626", "name": "62fd14d7-3f51-4606-8237-98874714c9e6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "48520c39-4eb5-43e5-86ce-ee13fd69508b"}}}]}, {"uuid": "3be1397a-8a05-4668-9b09-656b568aab4b", "name": "load_p1rlv13698_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3839c291-3f45-46c3-973f-6a9615fcf81b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1a354e32-b9f7-48a2-9d67-16babb502626"}}}}, {"uuid": "29c3eb53-e8e6-434d-b8b9-b5d0eeeef957", "name": "f2b3afb2-d9d1-4df0-bc47-cb542a352e1a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9800785435301127, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2597629929517743, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "efea7d55-d9c3-40d8-9974-1ec710094411", "name": "fdc6bcae-ed53-44fc-a78d-8e226ddf0975", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "29c3eb53-e8e6-434d-b8b9-b5d0eeeef957"}}}]}, {"uuid": "78ea114e-84ee-4615-baf9-4817aefbf5b8", "name": "load_p1rlv13700_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ecf9ee9-2a3c-431b-84c8-02c7c7aaacb1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "efea7d55-d9c3-40d8-9974-1ec710094411"}}}}, {"uuid": "3ac6bc75-465b-42b3-852e-eeb5e2d1037e", "name": "501c5d20-904e-4849-b8b3-9edea9c96d6e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9800785435301127, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2597629929517743, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "396a415b-295f-4d6d-962d-c35b69dbfb00", "name": "6233a0aa-0d77-4a61-a4d0-eea1dbb1ac97", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3ac6bc75-465b-42b3-852e-eeb5e2d1037e"}}}]}, {"uuid": "e240f08b-a2bd-43ef-9bc3-418489941ef9", "name": "load_p1rlv13700_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ecf9ee9-2a3c-431b-84c8-02c7c7aaacb1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "396a415b-295f-4d6d-962d-c35b69dbfb00"}}}}, {"uuid": "c7596c6f-33bf-4ce8-94b7-ce8450625e3e", "name": "7fa0faeb-9e91-41c9-a0ee-8f12863cd6ec_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.547211686956079, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18814377021524833, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e3af9236-7fa2-4281-89b0-939b2cc9f155", "name": "dc89826e-cbd4-4e83-a5dd-8763bef64cb9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c7596c6f-33bf-4ce8-94b7-ce8450625e3e"}}}]}, {"uuid": "eb4e4727-b4f0-46ec-826a-dbb1737983cb", "name": "load_p1rlv13701_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa7a324e-d367-49a5-820a-b18e72243265"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e3af9236-7fa2-4281-89b0-939b2cc9f155"}}}}, {"uuid": "64f28cd5-6b3a-49ee-b88b-876bf0d5f347", "name": "a33c02eb-f545-461b-bc95-84d092c7914e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.547211686956079, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18814377021524833, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "83710f86-c125-4c89-92ad-3a6ded5b40b9", "name": "e727b800-0e89-42c7-8c25-e590764f428a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "64f28cd5-6b3a-49ee-b88b-876bf0d5f347"}}}]}, {"uuid": "deae30e2-4d1e-4e45-92b3-0d11ee422fcb", "name": "load_p1rlv13701_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa7a324e-d367-49a5-820a-b18e72243265"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "83710f86-c125-4c89-92ad-3a6ded5b40b9"}}}}, {"uuid": "700b9b2f-11c3-4d94-b9b7-14206f86098b", "name": "ec7828bd-32bf-4859-b88f-9d00dbada00e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "13bab12d-d6b7-45e9-ba69-182dcf8a0a9b", "name": "741e51a1-eebf-437e-91ba-84cc74e720fc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "700b9b2f-11c3-4d94-b9b7-14206f86098b"}}}]}, {"uuid": "6a27aee9-62a0-48e0-a446-8b3d4f3219e7", "name": "load_p1rlv13702_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fe3c958-296f-4b51-8b2b-74bb34ddb5a6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "13bab12d-d6b7-45e9-ba69-182dcf8a0a9b"}}}}, {"uuid": "a9754e34-ddf1-4994-8ce0-4913a3e58681", "name": "b0090678-8998-4d48-a463-dd05e6730437_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "936f4ea1-214f-4414-8b34-6ce0bf9879d7", "name": "54c22d49-2d81-4419-89f9-1ad89c5904de", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a9754e34-ddf1-4994-8ce0-4913a3e58681"}}}]}, {"uuid": "b405cc7f-aac6-4979-b0e8-4bc67aaf6e2e", "name": "load_p1rlv13702_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fe3c958-296f-4b51-8b2b-74bb34ddb5a6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "936f4ea1-214f-4414-8b34-6ce0bf9879d7"}}}}, {"uuid": "ad6f3996-5250-4903-900c-98cc80721468", "name": "e8a90a05-9c86-433f-a9ad-9ad3bb2f8b82_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2769071780208345, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4029118207034132, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "95c019d8-e7bf-4afd-a080-a6f621649229", "name": "05eeeca4-83c7-4501-b26c-d31da230df29", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ad6f3996-5250-4903-900c-98cc80721468"}}}]}, {"uuid": "3dab6f65-4632-4a3b-b353-50d00476b9c7", "name": "load_p1rlv13703_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9efacf5-5b96-4670-b6f1-dc398485cde9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "95c019d8-e7bf-4afd-a080-a6f621649229"}}}}, {"uuid": "97c46857-975d-412a-a4e0-5809874f5c16", "name": "ecb942cd-9b32-4043-b0e8-dc7a236faee7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2769071780208345, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4029118207034132, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f5e1e662-9c2f-48a5-85fb-d172280f7787", "name": "a31d2e6f-e64f-4b3d-b7d7-d3bb98c08c73", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "97c46857-975d-412a-a4e0-5809874f5c16"}}}]}, {"uuid": "bcb30f07-f390-431a-9ff8-0cde94b4035a", "name": "load_p1rlv13703_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9efacf5-5b96-4670-b6f1-dc398485cde9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f5e1e662-9c2f-48a5-85fb-d172280f7787"}}}}, {"uuid": "67e20fc8-11d1-4dc4-b232-49a9104fdd94", "name": "ddfc1f7d-1036-4cfa-9a48-fa1ba44fd782_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5d75438e-9f5d-481a-973d-ae138fa0337f", "name": "5fc81374-3427-4e96-8835-d0eb39e298a4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "67e20fc8-11d1-4dc4-b232-49a9104fdd94"}}}]}, {"uuid": "3b180503-e355-4f5c-9e1e-c2dca49a1d38", "name": "load_p1rlv13705_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f409299-5ac0-4f31-a217-d0aef7fbc4d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5d75438e-9f5d-481a-973d-ae138fa0337f"}}}}, {"uuid": "4b785ece-1a3a-4873-93a0-aaff723e54ea", "name": "26668d8a-2dbe-4359-a6bb-451d9a76228c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0b47fcab-65b9-4a82-b1bb-a2a21beb6138", "name": "903b60ff-3b21-4883-8b18-faae551c3d75", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4b785ece-1a3a-4873-93a0-aaff723e54ea"}}}]}, {"uuid": "284635fd-7a8a-4cf2-b20e-40b17b78ba7b", "name": "load_p1rlv13705_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f409299-5ac0-4f31-a217-d0aef7fbc4d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0b47fcab-65b9-4a82-b1bb-a2a21beb6138"}}}}, {"uuid": "c19162f1-9baa-4f3a-8e29-091896a65a63", "name": "44433df7-721c-49f3-9d4a-3f79a6898b62_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "49ba3689-a5c8-4f05-88d4-29a5f9a32264", "name": "bc6dd17f-97b0-46bb-b18d-a96ac1e78365", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c19162f1-9baa-4f3a-8e29-091896a65a63"}}}]}, {"uuid": "6ffcabfc-6189-4923-9459-f810143a516a", "name": "load_p1rlv13706_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e60fc98a-9c1d-4975-a9b9-e37271b4ac81"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "49ba3689-a5c8-4f05-88d4-29a5f9a32264"}}}}, {"uuid": "43c584f4-0f3c-4289-bee3-b8198dccaf4d", "name": "4807c297-4619-4dbb-ac3a-93b5cd05776e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ee8dd868-18b6-4d0f-881b-f0cc44f0ca24", "name": "d7cfc5db-df8b-4faa-ab3e-40d38ee914fa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "43c584f4-0f3c-4289-bee3-b8198dccaf4d"}}}]}, {"uuid": "bc3cf296-500e-48df-8860-073864e4dd2b", "name": "load_p1rlv13706_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e60fc98a-9c1d-4975-a9b9-e37271b4ac81"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ee8dd868-18b6-4d0f-881b-f0cc44f0ca24"}}}}, {"uuid": "6413e194-03e5-48c7-88a6-50f535f3a72a", "name": "ff48c4d2-8b8a-42b7-8b13-547e96dc9bd6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1f78e963-e9df-4f71-b59b-b7020b109583", "name": "7e30d6c4-12cd-4aab-8b47-451df08c4733", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6413e194-03e5-48c7-88a6-50f535f3a72a"}}}]}, {"uuid": "e95cd4c6-356c-4db2-be42-22421b873317", "name": "load_p1rlv13707_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "286623b3-af08-4a60-896a-1f5b85fe04a5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1f78e963-e9df-4f71-b59b-b7020b109583"}}}}, {"uuid": "3366db9e-3cf3-4151-8361-83b441a1f30e", "name": "22f79fb6-2b63-4702-ab85-effb7f238529_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a0851e07-4737-49ff-84ad-daa6bc98b911", "name": "694b01b0-174c-47ff-8dd6-2ba5e1fe9d3d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3366db9e-3cf3-4151-8361-83b441a1f30e"}}}]}, {"uuid": "56d76667-0cdd-48ef-a18b-ed51d5d65d1e", "name": "load_p1rlv13707_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "286623b3-af08-4a60-896a-1f5b85fe04a5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a0851e07-4737-49ff-84ad-daa6bc98b911"}}}}, {"uuid": "75952726-7480-4eb3-8fca-e410a5609a32", "name": "1171d848-94aa-4d3f-85e2-f6b2a083abf4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "66c585a7-9929-4d9e-b2c0-4038ef131727", "name": "97b55cae-aa0a-4c34-987e-efdb2ef1e497", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "75952726-7480-4eb3-8fca-e410a5609a32"}}}]}, {"uuid": "49afa33d-2db8-4c25-baf0-db76d22a5b78", "name": "load_p1rlv13708_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a230534-6927-4af8-ba54-6ab4c9c32d21"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "66c585a7-9929-4d9e-b2c0-4038ef131727"}}}}, {"uuid": "6f76b578-9e6c-4143-9fa1-0a9d00e81721", "name": "58d582ca-d92e-49a9-afa0-3d49ad5ddf68_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "75a5498f-0a83-4d9a-a17e-bdde0fccc40d", "name": "3842aa62-58e8-4549-b39a-ef1b378b39d4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6f76b578-9e6c-4143-9fa1-0a9d00e81721"}}}]}, {"uuid": "e17a4e5a-76ab-4e2b-9deb-0ddc2436202c", "name": "load_p1rlv13708_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a230534-6927-4af8-ba54-6ab4c9c32d21"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "75a5498f-0a83-4d9a-a17e-bdde0fccc40d"}}}}, {"uuid": "b23ca2b3-f01b-4a70-9c20-3ef8d65883bc", "name": "92063d80-548f-4737-aba3-d38c65b55fda_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "58ee1ba5-d4cd-483f-b539-6f48b5664106", "name": "620fd620-3af1-4383-9614-c5fa3611b9b6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b23ca2b3-f01b-4a70-9c20-3ef8d65883bc"}}}]}, {"uuid": "6bd8147e-4da1-41f0-ab34-81bf5be88280", "name": "load_p1rlv13711_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2bfaa34-267c-4dfd-8b6d-4ab444ac4048"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "58ee1ba5-d4cd-483f-b539-6f48b5664106"}}}}, {"uuid": "b216556a-58a2-4ff4-b485-d2e41df9d5c5", "name": "46df789e-0b71-4086-9338-f9f9abed9eea_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6508feb2-672c-4f09-bedf-352defe69273", "name": "8a7044d2-9623-4090-9535-7b77ebdfd4e1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b216556a-58a2-4ff4-b485-d2e41df9d5c5"}}}]}, {"uuid": "29ab3c31-513d-4ba8-92a0-46a0df8c64dc", "name": "load_p1rlv13711_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2bfaa34-267c-4dfd-8b6d-4ab444ac4048"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6508feb2-672c-4f09-bedf-352defe69273"}}}}, {"uuid": "6418ab48-9339-4497-855a-b597731a1243", "name": "cc53d833-c02e-462e-aaa6-5805e0b3df3b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7545306166330135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0868234997236217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "146c8f5e-86e7-4955-9415-724b425e7d92", "name": "b490587e-dcfa-48bf-bb38-9da514ff2a94", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6418ab48-9339-4497-855a-b597731a1243"}}}]}, {"uuid": "ff3b22fc-25ef-4ea2-ad20-a01769dd6228", "name": "load_p1rlv13712_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ab8bce-7c02-4c7b-962e-3fb44a3ab7a9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "146c8f5e-86e7-4955-9415-724b425e7d92"}}}}, {"uuid": "97ab516e-1b75-4db4-a02f-2a3e534364ed", "name": "edbd1e33-e791-41c6-adbf-15ff89ddf2f5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7545306166330135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0868234997236217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4f328d12-489d-4a0a-ac22-c15f688ebf38", "name": "cf4b514d-e94c-426f-ac7e-479f28cfb2ed", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "97ab516e-1b75-4db4-a02f-2a3e534364ed"}}}]}, {"uuid": "6bd90a3f-7030-4ebd-8435-2deaa7b3287c", "name": "load_p1rlv13712_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ab8bce-7c02-4c7b-962e-3fb44a3ab7a9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4f328d12-489d-4a0a-ac22-c15f688ebf38"}}}}, {"uuid": "aa2897bb-6c94-4c97-beed-05beeab0409b", "name": "7eb4941e-aab2-4b82-97d4-e5a1bea33332_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fd3fa0fb-eefc-44ed-bd10-dbc69cc69dbd", "name": "409fecca-9d80-4bfd-a225-8e9f1fa11b15", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aa2897bb-6c94-4c97-beed-05beeab0409b"}}}]}, {"uuid": "01e08a61-f12d-44e2-97f7-d9d92ef0dd55", "name": "load_p1rlv13713_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee766a99-bb6f-4d5c-8513-9d462103f6fc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fd3fa0fb-eefc-44ed-bd10-dbc69cc69dbd"}}}}, {"uuid": "72227943-9753-4764-89fd-9a52b2ff60b7", "name": "992e2843-abba-4520-b23a-1ae2deee57db_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c853f8ef-2cf1-4a41-8fb3-40148f6182d7", "name": "e07790a4-62ba-4aad-9b20-dee50a745a9d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72227943-9753-4764-89fd-9a52b2ff60b7"}}}]}, {"uuid": "d6d84b9a-453c-41d6-a1fc-e90bfc7c4af3", "name": "load_p1rlv13713_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee766a99-bb6f-4d5c-8513-9d462103f6fc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c853f8ef-2cf1-4a41-8fb3-40148f6182d7"}}}}, {"uuid": "754509b2-e93c-4cc1-ba8e-8f881a1b87e6", "name": "fcfdc003-f539-4d06-97f6-74b531454884_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9972586284721718, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5405993695804993, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8e3a8735-5c81-4955-ade7-ef788305f464", "name": "d85f1cf8-8756-4671-afc2-58fc47a83939", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "754509b2-e93c-4cc1-ba8e-8f881a1b87e6"}}}]}, {"uuid": "4618bcd0-4a49-42cb-a947-1ad974ae77c8", "name": "load_p1rlv13714_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17936036-1191-4f91-bc12-2298db7b77e3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8e3a8735-5c81-4955-ade7-ef788305f464"}}}}, {"uuid": "b47fcbac-90fa-4e88-97c5-2a030255e0c9", "name": "7d7b8d24-c368-427a-a6c5-39287240dca0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9972586284721718, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5405993695804993, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "98e26e6f-9bb9-4e70-8144-92a64d3fff47", "name": "be31ff26-26d7-4011-b6e4-9a2d9c7656d3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b47fcbac-90fa-4e88-97c5-2a030255e0c9"}}}]}, {"uuid": "6a9508d2-1734-48c3-8444-79bb54072e1b", "name": "load_p1rlv13714_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17936036-1191-4f91-bc12-2298db7b77e3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "98e26e6f-9bb9-4e70-8144-92a64d3fff47"}}}}, {"uuid": "9e151eb7-5f81-440f-974d-fe976df01299", "name": "1d91d7eb-1e63-4f9f-b435-1197599db6d1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "57633dc2-dcd6-4729-a316-4e096ed1f292", "name": "36e71770-34f7-46bb-afd0-ed2986df6ca6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9e151eb7-5f81-440f-974d-fe976df01299"}}}]}, {"uuid": "c812a679-890c-4d0f-98d9-0d1f7d45f99d", "name": "load_p1rlv13715_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a822fdb0-b531-49b0-89da-b517e5ae6e3a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "57633dc2-dcd6-4729-a316-4e096ed1f292"}}}}, {"uuid": "92649058-d744-41bd-91d4-969ee02e3557", "name": "71d0b39e-c5df-4efb-b9d0-b7bb3e2d3f60_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f2dfe100-e76c-4b08-ab10-7eafc439ced1", "name": "d7fb2e79-b36a-4da1-9450-e76fda612f21", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "92649058-d744-41bd-91d4-969ee02e3557"}}}]}, {"uuid": "5523e36f-b164-4cd1-b47f-790f9d2080f0", "name": "load_p1rlv13715_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a822fdb0-b531-49b0-89da-b517e5ae6e3a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f2dfe100-e76c-4b08-ab10-7eafc439ced1"}}}}, {"uuid": "6fcedadc-5687-4d32-801f-41ea8517173a", "name": "b9c70ccf-2ea5-4a70-8329-c5a5c75154eb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0fb544c1-e897-425d-9c92-9a04c78144f4", "name": "5b8ab658-643d-4572-9f87-1dfc56ee539d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6fcedadc-5687-4d32-801f-41ea8517173a"}}}]}, {"uuid": "9373a3d8-431a-4e5b-bc97-72b35793721a", "name": "load_p1rlv13716_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb3b4207-12ad-46e6-b4de-59149a46f8a1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0fb544c1-e897-425d-9c92-9a04c78144f4"}}}}, {"uuid": "6c990dc3-9aae-434f-be73-936224343e7d", "name": "a1327074-a0dd-4963-980d-8c1955fa3f43_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "07876a8a-aef7-4bb8-83b4-1ce723379caa", "name": "e9b74712-8026-4896-b0d9-748f9f85c33b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c990dc3-9aae-434f-be73-936224343e7d"}}}]}, {"uuid": "0d8ddad1-6cb5-490c-a4a7-08840429a56d", "name": "load_p1rlv13716_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb3b4207-12ad-46e6-b4de-59149a46f8a1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "07876a8a-aef7-4bb8-83b4-1ce723379caa"}}}}, {"uuid": "7b4d227c-71c5-44be-a753-27a2e2d3c822", "name": "d7ba2655-5d70-485e-a3e2-d7dab97b4ffb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "083c693f-7451-4a82-98a6-fd33ae600b7a", "name": "254e231c-54d2-4360-84e4-cb99d595c499", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b4d227c-71c5-44be-a753-27a2e2d3c822"}}}]}, {"uuid": "40c3c225-3dc3-4e2a-8cb6-a855fc0d6d40", "name": "load_p1rlv13717_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdbfe616-f51f-416a-94ce-6e676d300226"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "083c693f-7451-4a82-98a6-fd33ae600b7a"}}}}, {"uuid": "5fd7b8b0-61ac-48cd-ab38-7094e02b1c97", "name": "fd0f1747-45ce-40d0-b4b5-2f8db2d3681c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d98c18a0-87e8-428f-a555-1a94776ba879", "name": "db0912c1-87b2-4d95-b1f8-28ada67f3122", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5fd7b8b0-61ac-48cd-ab38-7094e02b1c97"}}}]}, {"uuid": "0015d220-ad70-47b2-b3a3-4672d57385af", "name": "load_p1rlv13717_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdbfe616-f51f-416a-94ce-6e676d300226"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d98c18a0-87e8-428f-a555-1a94776ba879"}}}}, {"uuid": "25542898-6b2c-4f16-af7d-d7b082c9a12a", "name": "385d9c16-4654-417c-b777-7aa08f6a082a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6027984746974515, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12293402966163972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4632ff26-1435-4900-8c24-064f89444d78", "name": "ae548c79-9b0f-4aec-bbd3-caf8815c145e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "25542898-6b2c-4f16-af7d-d7b082c9a12a"}}}]}, {"uuid": "e97f8a95-0a85-4426-a5d7-bf700b901a92", "name": "load_p1rlv13719_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44aa3f37-e0db-4050-b47f-ac14b7fa6534"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4632ff26-1435-4900-8c24-064f89444d78"}}}}, {"uuid": "0ead7666-1788-4c58-9475-78f07dbfb2c7", "name": "ad3f2d2e-c3ce-4ceb-b06e-a313b53c404b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6027984746974515, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12293402966163972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4f684ec0-59a6-4e94-8609-46ee2f369b86", "name": "93bf93cf-51e3-4a04-bcd7-07e3527deb4e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0ead7666-1788-4c58-9475-78f07dbfb2c7"}}}]}, {"uuid": "0c2ba3a8-52db-4453-98c3-67ef3943039d", "name": "load_p1rlv13719_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44aa3f37-e0db-4050-b47f-ac14b7fa6534"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4f684ec0-59a6-4e94-8609-46ee2f369b86"}}}}, {"uuid": "065ac14e-ad43-4f8a-83bc-458d5a376d9e", "name": "2cfb0ada-7713-4150-b59c-1764af325937_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.693271865954936, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.115673740909077, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f032b135-567f-41e1-8f02-30eeb30cae74", "name": "2cfb0ada-7713-4150-b59c-1764af325937_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.693271865954936, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.115673740909077, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f66981dc-9a7f-4d48-9c9a-d014312e2040", "name": "2cfb0ada-7713-4150-b59c-1764af325937_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.693271865954936, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.115673740909077, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8b79ad69-4cec-4070-b217-a724f6a87163", "name": "18df2ab4-f102-49e3-b6d5-46c286393f54", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "065ac14e-ad43-4f8a-83bc-458d5a376d9e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f032b135-567f-41e1-8f02-30eeb30cae74"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f66981dc-9a7f-4d48-9c9a-d014312e2040"}}}]}, {"uuid": "40539eb5-04a1-47e8-a33d-f250c4efcda6", "name": "load_p1rlv13720", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fe1a5da7-bdac-46a6-ab32-addc4f02a296"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8b79ad69-4cec-4070-b217-a724f6a87163"}}}}, {"uuid": "a4bea439-76cd-4468-a365-8b99869e18b0", "name": "ff334ece-0414-4a5d-978d-16814908ce78_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.498014754859445, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0be10e40-addc-44a0-95b8-17c2667d64b0", "name": "865d928c-09a8-4aa7-89d9-5402b1f98597", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a4bea439-76cd-4468-a365-8b99869e18b0"}}}]}, {"uuid": "4532d3a3-933d-4350-bf56-5f09d7e02f59", "name": "load_p1rlv13721_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6097c903-70fc-4635-a66c-fee2243ba545"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0be10e40-addc-44a0-95b8-17c2667d64b0"}}}}, {"uuid": "cf061642-a570-42d7-b6a1-bda4f7bf11ad", "name": "376a1a9f-7a87-4dc5-8f2b-c2e69d99aedb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.498014754859445, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2f0f3560-d5e9-45dc-8fa1-57c4492d0228", "name": "b2f84c5f-390e-4a57-b294-a258c93c856b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cf061642-a570-42d7-b6a1-bda4f7bf11ad"}}}]}, {"uuid": "e2a2af36-b6fb-44d1-9b8d-8a541a55cbc9", "name": "load_p1rlv13721_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6097c903-70fc-4635-a66c-fee2243ba545"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2f0f3560-d5e9-45dc-8fa1-57c4492d0228"}}}}, {"uuid": "cbaebd38-060c-47f8-a31d-82317d5498d4", "name": "8400bf58-7f39-43b7-8782-b26400ae2afa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0772156037646567, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.01984596164170695, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "adb63022-7bff-420c-9630-a71369c1173d", "name": "93f5ad57-9582-470d-b478-7cf205431bde", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cbaebd38-060c-47f8-a31d-82317d5498d4"}}}]}, {"uuid": "5913b235-7f23-44d3-9bed-4855db1ffb03", "name": "load_p1rlv13723_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0f1846b-2515-48ef-9241-0276932f8e75"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "adb63022-7bff-420c-9630-a71369c1173d"}}}}, {"uuid": "63a5c690-9991-4d51-b11e-65fa0936739c", "name": "e646f638-eead-4a67-a015-aabf77b9dfdd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0772156037646567, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.01984596164170695, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a4afb26a-6c9f-4511-b59f-42dc4d6fc4b6", "name": "fbda14f5-a977-4076-bac2-a87ecd3c5a6b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "63a5c690-9991-4d51-b11e-65fa0936739c"}}}]}, {"uuid": "4978d1b9-2594-4bf0-af8d-9600ad7d7685", "name": "load_p1rlv13723_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0f1846b-2515-48ef-9241-0276932f8e75"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a4afb26a-6c9f-4511-b59f-42dc4d6fc4b6"}}}}, {"uuid": "3b053fe4-7517-4e8b-a5db-7c0200c5301f", "name": "09d2550e-5249-4897-86b2-15f06064b6df_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6277722044378486, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6969686665668667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7370b0bd-80cd-433b-9192-bc43c5e1a7be", "name": "7c3ad141-20bd-4f8a-ae12-33ad20556a42", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3b053fe4-7517-4e8b-a5db-7c0200c5301f"}}}]}, {"uuid": "a45714a0-7b14-4206-955f-80f8c450db3d", "name": "load_p1rlv13724_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "457c6c9d-5020-4cf3-9c1e-c36012a619d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7370b0bd-80cd-433b-9192-bc43c5e1a7be"}}}}, {"uuid": "58a76492-a584-4280-918a-07b715d387df", "name": "7b59b86e-a70a-42ac-a0ac-c35549727ff6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6277722044378486, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6969686665668667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a143659c-ad8d-4069-a8e5-cb7f495a2ab8", "name": "ddac1d04-e4a4-4508-b483-e46fc85dcad2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58a76492-a584-4280-918a-07b715d387df"}}}]}, {"uuid": "2f81c172-7861-4ac1-8635-9c7b7be1eea0", "name": "load_p1rlv13724_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "457c6c9d-5020-4cf3-9c1e-c36012a619d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a143659c-ad8d-4069-a8e5-cb7f495a2ab8"}}}}, {"uuid": "4f7e210b-8657-4907-afb0-2fdeb6ad39f8", "name": "7f12debb-47ea-4b10-814d-ebf7df7088b1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4699462180170992, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3815978523472859, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f722faea-19a7-4445-a5ba-aabe9951ae25", "name": "91821276-4178-4e96-9357-2242c8f18dcf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4f7e210b-8657-4907-afb0-2fdeb6ad39f8"}}}]}, {"uuid": "b3032777-00a4-4e8d-b124-8e1154386c77", "name": "load_p1rlv13725_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e290046b-c936-4f51-b4ef-632bf572ab7f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f722faea-19a7-4445-a5ba-aabe9951ae25"}}}}, {"uuid": "0e7e24f0-18d9-4954-a6ec-adedf0f98db4", "name": "fadc48c3-d531-4be2-b3d2-977404485f0c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4699462180170992, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3815978523472859, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "16112990-2183-48fd-b59c-e1c31239ab37", "name": "01c5727b-1947-47bd-aa23-129b2373e7f0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0e7e24f0-18d9-4954-a6ec-adedf0f98db4"}}}]}, {"uuid": "ecf2d690-b53e-409e-bd12-3fe278a4a408", "name": "load_p1rlv13725_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e290046b-c936-4f51-b4ef-632bf572ab7f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "16112990-2183-48fd-b59c-e1c31239ab37"}}}}, {"uuid": "ea59716e-ff02-4fe0-96c9-98334af45343", "name": "ccb1f4b6-7666-40ab-805b-387e4127deff_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.559543722017981, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7101531402521069, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "024d4b5b-caec-4dd8-9523-0dd3f77ec616", "name": "77ee0385-e9d9-4ce9-9814-3f1f72612aa2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ea59716e-ff02-4fe0-96c9-98334af45343"}}}]}, {"uuid": "a1074246-39b6-4a84-9bb3-bab5de04efcb", "name": "load_p1rlv13726_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "642597e6-fe60-442f-b356-2be6f21677b2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "024d4b5b-caec-4dd8-9523-0dd3f77ec616"}}}}, {"uuid": "8097c180-7252-4a8f-a0c2-31caa4e0bcd5", "name": "d5075581-9fed-4669-a63b-22e5f594bb9f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.559543722017981, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7101531402521069, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1612c2b3-272a-438e-a8a2-9c070b656f67", "name": "f41c0c3f-0dbb-445c-89f4-14d751b99d4c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8097c180-7252-4a8f-a0c2-31caa4e0bcd5"}}}]}, {"uuid": "772e3056-1184-4bbd-8456-11bb88f849a8", "name": "load_p1rlv13726_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "642597e6-fe60-442f-b356-2be6f21677b2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1612c2b3-272a-438e-a8a2-9c070b656f67"}}}}, {"uuid": "570b274f-388c-4c5e-8765-e1f43c2d99c8", "name": "a73059bb-e437-48a1-a2e4-b6ea38a2ec24_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.70898089652498, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7830599711618245, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a3e04680-3dfe-4696-aa2f-3d698a557628", "name": "914c2206-d850-42aa-9034-897718169bba", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "570b274f-388c-4c5e-8765-e1f43c2d99c8"}}}]}, {"uuid": "32c8420d-bc08-4ddf-8ad2-5c1a91750b99", "name": "load_p1rlv13727_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36019623-eb62-412c-a591-41494980c9b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a3e04680-3dfe-4696-aa2f-3d698a557628"}}}}, {"uuid": "045e5b4c-a5d1-493d-b89f-abaec81c479b", "name": "595944c9-4275-4c6a-8559-118d0090546e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.70898089652498, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7830599711618245, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1f4e5df6-c5db-4a5d-8c90-987416e54d98", "name": "923d034c-aa7d-4a9f-b117-fc14c9d85510", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "045e5b4c-a5d1-493d-b89f-abaec81c479b"}}}]}, {"uuid": "23ec0f8d-ad28-4acf-833c-91ed0581460c", "name": "load_p1rlv13727_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36019623-eb62-412c-a591-41494980c9b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1f4e5df6-c5db-4a5d-8c90-987416e54d98"}}}}, {"uuid": "2f09022f-95e8-4f03-94eb-632b3deb5bb2", "name": "5e42c9ef-4052-4d9d-96a7-e6436c2a4815_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 12.611907582113087, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.885290064059574, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c9f56e64-a595-48aa-a382-bcb537d235f4", "name": "e80b2ee4-a8a5-4d22-b5bb-257be53e5acc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2f09022f-95e8-4f03-94eb-632b3deb5bb2"}}}]}, {"uuid": "9a416140-7041-43b6-b2bd-25ee741cb466", "name": "load_p1rlv13728_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9657a993-0005-4ffc-8c9f-18e80a491070"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c9f56e64-a595-48aa-a382-bcb537d235f4"}}}}, {"uuid": "6835f5d8-a666-42d4-9f3f-4c86fe3ed12a", "name": "cac9a18c-75a4-4d56-a1cd-2880d62c8486_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 12.611907582113087, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.885290064059574, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "053915d4-d4ac-42e4-b303-1e25bbde93b1", "name": "2f2112f0-e24c-4a82-9929-c3bc07c98c09", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6835f5d8-a666-42d4-9f3f-4c86fe3ed12a"}}}]}, {"uuid": "92fc514e-a83d-4451-935b-c49f7cee00a2", "name": "load_p1rlv13728_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9657a993-0005-4ffc-8c9f-18e80a491070"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "053915d4-d4ac-42e4-b303-1e25bbde93b1"}}}}, {"uuid": "0b48ddbd-a8b0-489e-9867-ef8439109a26", "name": "9297ef60-e9ea-4582-843d-ca70d318c44d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.028781788264419, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6709073147144231, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "12d5a0f8-56fc-40b7-8f45-1bf67557aee7", "name": "a105314f-aa53-4476-942b-c5766d404511", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0b48ddbd-a8b0-489e-9867-ef8439109a26"}}}]}, {"uuid": "e2fe9658-1741-473a-bd57-9eb0b2f3485f", "name": "load_p1rlv13784_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01a18948-75cf-4caf-951f-17a9c8d1f6bc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "12d5a0f8-56fc-40b7-8f45-1bf67557aee7"}}}}, {"uuid": "7306ded9-8b69-4dbe-86d5-7ea4fb33190c", "name": "086b660b-e051-4ebe-8a74-ed7483f89e33_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.028781788264419, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6709073147144231, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e85fd6fb-5334-49b7-8a84-405c8bb4daa7", "name": "9494e3dd-556a-41ff-a9ef-3612c4ae268e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7306ded9-8b69-4dbe-86d5-7ea4fb33190c"}}}]}, {"uuid": "d4e8b427-9fc7-4230-85f4-304d66ccd6c9", "name": "load_p1rlv13784_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01a18948-75cf-4caf-951f-17a9c8d1f6bc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e85fd6fb-5334-49b7-8a84-405c8bb4daa7"}}}}, {"uuid": "ae3335b0-295f-42bf-9b0d-e8c237fc40ce", "name": "4060d010-a34b-4f61-8baf-4b0fe8cf82ab_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7293ed3d-db31-4b0f-84ed-e1072d29fbec", "name": "fb539322-9819-40d4-b232-831a1dde2861", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ae3335b0-295f-42bf-9b0d-e8c237fc40ce"}}}]}, {"uuid": "e8de7c85-8abc-4098-92f1-6c262259c9af", "name": "load_p1rlv13792_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc5fcb56-435a-4a0d-b442-7489a98ad1cd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7293ed3d-db31-4b0f-84ed-e1072d29fbec"}}}}, {"uuid": "d2033207-79e4-41b4-872b-3ed0e60c5126", "name": "d4f5c4fa-ad8a-4e7b-a6ca-6797dbe1c260_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "be6d7968-c8a6-4621-aded-3efc1b5efcdf", "name": "042507ee-5a14-4ec3-9d92-871b2b26fa62", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d2033207-79e4-41b4-872b-3ed0e60c5126"}}}]}, {"uuid": "474c83a9-55f4-443c-b6fd-1267c438ab86", "name": "load_p1rlv13792_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc5fcb56-435a-4a0d-b442-7489a98ad1cd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "be6d7968-c8a6-4621-aded-3efc1b5efcdf"}}}}, {"uuid": "5b948bc6-9a04-4795-bfa9-01eb6d87861c", "name": "f74d6c3d-0371-4640-ab31-1c93d9435f40_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1648375907215343, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4430202395847888, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3757cab6-2ee7-4a95-9d71-ee3846d99760", "name": "f29f50b2-b0c2-4aac-9fb3-11b6e10eacf8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b948bc6-9a04-4795-bfa9-01eb6d87861c"}}}]}, {"uuid": "729053e2-f61f-4ddf-a62e-79e8d78caee2", "name": "load_p1rlv13794_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9725b6c-5bac-456a-bb6a-ce16a5e6b1a5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3757cab6-2ee7-4a95-9d71-ee3846d99760"}}}}, {"uuid": "22f8b219-1ab3-4775-8009-4d45ab313fe2", "name": "cf79beb3-0468-457c-93c0-5927e700c10b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1648375907215343, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4430202395847888, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e19d4fa9-8881-432a-96f0-f4c01ce935d6", "name": "3a35aef1-8f52-4b9f-8de2-b4a9e23b2983", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "22f8b219-1ab3-4775-8009-4d45ab313fe2"}}}]}, {"uuid": "1a73fa78-912f-42a0-b075-c5e4f8e75dab", "name": "load_p1rlv13794_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9725b6c-5bac-456a-bb6a-ce16a5e6b1a5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e19d4fa9-8881-432a-96f0-f4c01ce935d6"}}}}, {"uuid": "2b094398-1b00-4649-8d7d-ec234c2cddf5", "name": "62c30933-adac-4a05-b9f2-bee562077aa1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9518333270985427, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3340330193202704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3f11dbf6-443f-4bdf-aee0-650b675953bc", "name": "9a000fbc-b2e7-4a6c-9203-504fefd68405", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2b094398-1b00-4649-8d7d-ec234c2cddf5"}}}]}, {"uuid": "88688a62-05b0-48d5-a2fc-b720e3b3611e", "name": "load_p1rlv13797_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65052833-aec9-4363-a0cf-4d70fa9bb0ce"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3f11dbf6-443f-4bdf-aee0-650b675953bc"}}}}, {"uuid": "b9ce6736-7aa9-4e91-a962-bf314292f154", "name": "85fdcf94-c44a-429f-aab8-c3604ee2a35e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9518333270985427, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3340330193202704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1e15fbf3-d3eb-46e6-9043-f08cba648a41", "name": "72e7bea1-9154-4c38-b781-660b6f0b1f12", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b9ce6736-7aa9-4e91-a962-bf314292f154"}}}]}, {"uuid": "b7f8b025-5f44-4628-aebc-fb733bf3a827", "name": "load_p1rlv13797_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65052833-aec9-4363-a0cf-4d70fa9bb0ce"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1e15fbf3-d3eb-46e6-9043-f08cba648a41"}}}}, {"uuid": "d008dff8-0eca-43b2-a489-dddf1259f8b1", "name": "8263be69-f301-49f1-ad74-aff7cea45575_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.661093206685493, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9884186563142763, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2c148610-e18e-42ff-86f5-86f7e7d46e1c", "name": "33001303-0875-48b6-9db5-97731631a2ce", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d008dff8-0eca-43b2-a489-dddf1259f8b1"}}}]}, {"uuid": "1c9bbfba-9960-4261-8309-cf060c9695a0", "name": "load_p1rlv13805_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83d60921-a1f2-4b9c-9709-d2be59b82db5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2c148610-e18e-42ff-86f5-86f7e7d46e1c"}}}}, {"uuid": "d99dc7bf-d409-4931-8fca-5f94a2b89c2d", "name": "f1db1921-7c69-4ceb-a463-94b278426670_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.661093206685493, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9884186563142763, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "46ebd613-17d9-427f-9c79-d5e5beeb5dec", "name": "98235c32-1c83-4c03-8da0-0d2c93bd8a2a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d99dc7bf-d409-4931-8fca-5f94a2b89c2d"}}}]}, {"uuid": "f1119480-14dc-4bfe-bc02-83f47b1c6f79", "name": "load_p1rlv13805_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83d60921-a1f2-4b9c-9709-d2be59b82db5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "46ebd613-17d9-427f-9c79-d5e5beeb5dec"}}}}, {"uuid": "f99e86d1-f09c-4c75-a62c-86a281b8e3de", "name": "b85266ba-b80c-4fd8-a566-d2195631ff4e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4464370236076721, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16599396793014964, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bf53e031-d4a6-48aa-a830-5c127fd126cb", "name": "c7f377ac-0f6f-45f4-94d6-62ce97af7fd5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f99e86d1-f09c-4c75-a62c-86a281b8e3de"}}}]}, {"uuid": "b310fa6b-3561-4f44-8c02-3fe5845177b1", "name": "load_p1rlv13811_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aef2ef8-706c-4316-be01-0707ddf0ac7c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bf53e031-d4a6-48aa-a830-5c127fd126cb"}}}}, {"uuid": "54c9112e-beac-4376-98fb-29a9fcd58369", "name": "497ad5bf-510b-454f-8e94-b0e25fc99de0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4464370236076721, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16599396793014964, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3f6629e0-d2f9-4154-9736-947e7689538b", "name": "72b40a6b-934a-44df-974f-5f432dfb5ea5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "54c9112e-beac-4376-98fb-29a9fcd58369"}}}]}, {"uuid": "4ae17924-c7b0-46b0-96b7-eb50d517392e", "name": "load_p1rlv13811_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aef2ef8-706c-4316-be01-0707ddf0ac7c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3f6629e0-d2f9-4154-9736-947e7689538b"}}}}, {"uuid": "bdab4977-8247-45c9-b12d-2c32d8ab1531", "name": "dd9d5f22-24e3-4e93-822d-9f8855946932_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4868228207229564, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16976956391895093, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ec7818b8-f415-4595-9286-203cafa19f52", "name": "3406079d-61de-4f6a-98e0-94b3c6186342", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bdab4977-8247-45c9-b12d-2c32d8ab1531"}}}]}, {"uuid": "d85187ab-becb-484f-9857-aa2f29732078", "name": "load_p1rlv13812_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ffd737b-a273-4a6c-91c6-351b5719f658"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ec7818b8-f415-4595-9286-203cafa19f52"}}}}, {"uuid": "bedef87c-cbc5-4343-8474-fdc4146c18ef", "name": "ccd49114-65bb-46d0-b5bf-20327daf6b3a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4868228207229564, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16976956391895093, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a33faf8d-ee17-4d08-ae59-f31c6d3430b7", "name": "e985d90e-4301-48f8-ac94-7932b0618b99", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bedef87c-cbc5-4343-8474-fdc4146c18ef"}}}]}, {"uuid": "2f70ad94-00e8-4947-9e08-561f3609687b", "name": "load_p1rlv13812_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ffd737b-a273-4a6c-91c6-351b5719f658"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a33faf8d-ee17-4d08-ae59-f31c6d3430b7"}}}}, {"uuid": "4ec6c000-17d6-4c00-bb2f-69d9421922fb", "name": "ed2a0538-3156-40d4-ba8a-b0061f7ae68a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2596055778412756, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4460523908595607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b3f55c19-e53c-43aa-b18a-7806debc8e10", "name": "fcfe9690-2ba1-4777-8755-0e648a44743e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4ec6c000-17d6-4c00-bb2f-69d9421922fb"}}}]}, {"uuid": "23a8dfde-cdf0-451c-b9bc-aee846edd2e6", "name": "load_p1rlv14434_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06135bd7-6a77-4f04-a439-4ce8c245447d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b3f55c19-e53c-43aa-b18a-7806debc8e10"}}}}, {"uuid": "50ec0c20-f152-4fd9-bdc8-ee03a07ede22", "name": "32214626-4faa-45ff-abe3-5416beeae5df_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2596055778412756, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4460523908595607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "37ced1c4-aaba-4f1f-85f2-327c2445e6f8", "name": "5f0e1323-82cf-4eed-9712-6fd2cc97e929", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "50ec0c20-f152-4fd9-bdc8-ee03a07ede22"}}}]}, {"uuid": "0a8f122e-7a9a-482f-a8c6-baeea7a29ca9", "name": "load_p1rlv14434_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06135bd7-6a77-4f04-a439-4ce8c245447d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "37ced1c4-aaba-4f1f-85f2-327c2445e6f8"}}}}, {"uuid": "2d0e31de-a0df-46f1-af90-1b937b60ca43", "name": "7cbf61d5-0ee4-47ce-9378-2b7d7c9764b9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.904546554088597, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7711735109904765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1aa2825e-0efd-4844-a72b-6df0455193e5", "name": "3c187500-8a3f-4463-8769-bf684e0c7eaf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2d0e31de-a0df-46f1-af90-1b937b60ca43"}}}]}, {"uuid": "081fe3c5-fef8-4a22-bc81-65e9d2728088", "name": "load_p1rlv14435_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d07f5065-df41-484d-8e8a-80b2ff4e0e9b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1aa2825e-0efd-4844-a72b-6df0455193e5"}}}}, {"uuid": "471a413f-2eaa-4197-bece-c67b603b162a", "name": "8ee074cf-d8bd-40db-acdd-38204fd9aa91_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.904546554088597, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7711735109904765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b734a13b-49ba-4216-981a-a1c26b8442c2", "name": "17d0d18e-bb91-411a-b7f1-b8ea738d3cfb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "471a413f-2eaa-4197-bece-c67b603b162a"}}}]}, {"uuid": "99d1a71f-f989-47fc-9f83-39b676d187bd", "name": "load_p1rlv14435_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d07f5065-df41-484d-8e8a-80b2ff4e0e9b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b734a13b-49ba-4216-981a-a1c26b8442c2"}}}}, {"uuid": "5e9875d5-2bd2-4a80-9fb0-5aa1837a67ca", "name": "f7f82c80-17c7-4f51-b255-1e93d8e027cc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.756100999166533, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1794980420068588, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "80d5b990-bd78-4ae5-a3b9-1d77a3da445b", "name": "7445fd14-5983-48a7-87ca-6e5659032878", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5e9875d5-2bd2-4a80-9fb0-5aa1837a67ca"}}}]}, {"uuid": "b9f752a7-b6e4-405d-add0-812f294bcf81", "name": "load_p1rlv14436_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad66e41a-88ab-443e-b10e-9e7b5b899119"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "80d5b990-bd78-4ae5-a3b9-1d77a3da445b"}}}}, {"uuid": "aff84010-8b8c-4a7f-9d4c-2c43694a952c", "name": "dbbbf139-0f95-48f5-acaa-086e1c44c25d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.756100999166533, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1794980420068588, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5cf4d181-0b70-4419-be75-5d3190cb1735", "name": "bef3bd59-9ee9-45c6-abb9-3fb7e9de4705", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aff84010-8b8c-4a7f-9d4c-2c43694a952c"}}}]}, {"uuid": "5564228d-f485-4130-86a3-04573a3e29b9", "name": "load_p1rlv14436_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad66e41a-88ab-443e-b10e-9e7b5b899119"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5cf4d181-0b70-4419-be75-5d3190cb1735"}}}}, {"uuid": "0dbe7793-0d47-4fe5-b038-3b999b242fae", "name": "4750cf80-9c97-4274-a712-b73798096b15_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7653657521185364, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4426471780914222, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3b82e80a-6324-40d2-b374-9db33fa5ef57", "name": "594897a8-f6aa-4272-b22b-26448d576c26", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0dbe7793-0d47-4fe5-b038-3b999b242fae"}}}]}, {"uuid": "82aca4f2-6c5b-4bc0-aae2-b5a49a64d263", "name": "load_p1rlv14828_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9efa4c9-9832-4aa8-bf44-be0fe1e80cd5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3b82e80a-6324-40d2-b374-9db33fa5ef57"}}}}, {"uuid": "5903d2f9-91a7-435c-a8cb-1f11fb6a26a6", "name": "87761cbc-dbf1-499a-a572-16632761c2ef_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7653657521185364, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4426471780914222, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "68492e2a-6570-4bce-a33d-57f001e3234d", "name": "a6054e8b-ee23-467a-bcd2-bc1425d9c6de", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5903d2f9-91a7-435c-a8cb-1f11fb6a26a6"}}}]}, {"uuid": "4c2198f5-7b12-499e-8ed8-99d3054d67db", "name": "load_p1rlv14828_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9efa4c9-9832-4aa8-bf44-be0fe1e80cd5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "68492e2a-6570-4bce-a33d-57f001e3234d"}}}}, {"uuid": "2f9dd3b5-b8b8-4e57-b14a-7648ea564701", "name": "045a91b1-8843-4bc1-8108-7545409dc696_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1976836424562762, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1051220183522544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c44694fe-ec4b-4975-90d4-b20dfc47bfda", "name": "27abf23f-031c-4ff8-a27f-946c42b90b7d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2f9dd3b5-b8b8-4e57-b14a-7648ea564701"}}}]}, {"uuid": "62705e48-23c3-40f1-ba30-985371f037f0", "name": "load_p1rlv14908_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d73b0321-e181-4ecd-b431-9aa6985d56d0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c44694fe-ec4b-4975-90d4-b20dfc47bfda"}}}}, {"uuid": "13973059-1455-492f-aa8d-4f0949f37171", "name": "de2f93d0-3b7f-47ef-847c-60e38ab38cf5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1976836424562762, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1051220183522544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c586f4c7-ef88-4352-8862-0775454adae6", "name": "41def184-fcb6-41ff-a21f-b6c96c5b1e91", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "13973059-1455-492f-aa8d-4f0949f37171"}}}]}, {"uuid": "5fb5c5f4-eb51-4b8f-964d-bda964502433", "name": "load_p1rlv14908_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d73b0321-e181-4ecd-b431-9aa6985d56d0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c586f4c7-ef88-4352-8862-0775454adae6"}}}}, {"uuid": "c451fcb3-16fc-4ab4-b742-9685f3c20147", "name": "046c2e5c-9bcd-49b7-985d-ff87924957d4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9dc3c26b-791e-418e-8438-ab88c139d380", "name": "793240ef-b02c-4623-b140-29599685560b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c451fcb3-16fc-4ab4-b742-9685f3c20147"}}}]}, {"uuid": "d353f84e-cf15-45cb-8dfe-3c455036fa82", "name": "load_p1rlv14952_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3c39b0c-9c92-4934-876f-ee5f542f95cc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9dc3c26b-791e-418e-8438-ab88c139d380"}}}}, {"uuid": "ada1f288-eb32-40fa-a93c-b178dc471a25", "name": "e6624cbc-01a1-4d75-a74d-6f51903b1cb6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7978430e-b47f-471e-abf3-c557209eb1af", "name": "71ca7f34-1f1f-4d74-b942-b183995d7a2b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ada1f288-eb32-40fa-a93c-b178dc471a25"}}}]}, {"uuid": "9c5c9761-f21a-4ed3-bbc7-c95e9ac88e6e", "name": "load_p1rlv14952_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3c39b0c-9c92-4934-876f-ee5f542f95cc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7978430e-b47f-471e-abf3-c557209eb1af"}}}}, {"uuid": "55ab0755-f6d0-4afe-a977-e9fe416d48e2", "name": "9a9b70aa-72c9-48c4-a97a-893f6c40a381_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.374506393438246, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.694445400364831, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0edb6602-5e0c-49db-af53-afaac6863971", "name": "81b0d1c0-35ef-4ae8-a27d-231ab99ead98", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "55ab0755-f6d0-4afe-a977-e9fe416d48e2"}}}]}, {"uuid": "ba37f6a9-d2e1-45fd-93f2-5592c7c07386", "name": "load_p1rlv14954_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9e128f5-eb18-44df-8ec4-35bd049ef630"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0edb6602-5e0c-49db-af53-afaac6863971"}}}}, {"uuid": "1b602400-59f5-47f9-9bde-fdaac8e37572", "name": "94af954a-5059-44d9-af06-f44215920afb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.374506393438246, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.694445400364831, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7b432e8c-65cf-4990-a136-2379e96e5e79", "name": "1ddba20c-906e-43c1-99f8-eb531288b44e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1b602400-59f5-47f9-9bde-fdaac8e37572"}}}]}, {"uuid": "3acda848-9982-497f-bebc-bed963f86579", "name": "load_p1rlv14954_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9e128f5-eb18-44df-8ec4-35bd049ef630"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7b432e8c-65cf-4990-a136-2379e96e5e79"}}}}, {"uuid": "faaf63ea-d3bd-4351-83df-e6a9432ebd55", "name": "6af9cafb-9b46-471d-a620-d791cde8077a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.749950841708346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2019248045205122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fc221dbf-f8e8-4ad9-bbf9-d8ae1e8a99f3", "name": "77966535-8c36-425a-9913-dcd3e54c7a90", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "faaf63ea-d3bd-4351-83df-e6a9432ebd55"}}}]}, {"uuid": "02ceef6f-f4f0-4a1d-bf34-d2b1cae4ccc5", "name": "load_p1rlv14974_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "884ff47e-8e20-4ae8-97bd-287d0ca9dc1b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fc221dbf-f8e8-4ad9-bbf9-d8ae1e8a99f3"}}}}, {"uuid": "a47ccb41-9101-4862-9919-266c22934ac6", "name": "41281d89-de87-494a-b10d-2065930fe40d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.749950841708346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2019248045205122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a7de7a39-b75c-496a-aa48-cac2e1e4e315", "name": "af67500e-fe6b-4ac5-b512-ab34bdc795d8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a47ccb41-9101-4862-9919-266c22934ac6"}}}]}, {"uuid": "935fef31-6064-44c6-b4e7-1d67031960e8", "name": "load_p1rlv14974_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "884ff47e-8e20-4ae8-97bd-287d0ca9dc1b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a7de7a39-b75c-496a-aa48-cac2e1e4e315"}}}}, {"uuid": "1c8a1050-9e99-4748-a965-b48dc79e1a7b", "name": "208ed43a-7564-4026-8572-a2af145b4198_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.446531565278448, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9314679219387375, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3d6ac767-6b08-40a3-afe2-fd754bdb6e44", "name": "6c859f0b-a1fc-46b5-9113-1bd2784ae024", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1c8a1050-9e99-4748-a965-b48dc79e1a7b"}}}]}, {"uuid": "e1739cc0-2f69-4dd4-8772-857e3b95a2da", "name": "load_p1rlv14992_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4f8b1bc-83c3-4819-9d98-9491df98d494"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3d6ac767-6b08-40a3-afe2-fd754bdb6e44"}}}}, {"uuid": "fa59870f-88a2-4890-9295-c01066faa555", "name": "b35a08ad-9702-4e0a-8707-72a6299a3d62_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.446531565278448, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9314679219387375, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a0f7b08-80b8-4e40-9c1f-5305c35720f2", "name": "f299f9be-c5b0-42ab-b5f5-5f804bd03d2f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fa59870f-88a2-4890-9295-c01066faa555"}}}]}, {"uuid": "9419b869-2e79-4f11-9b36-8a2d43f5ca86", "name": "load_p1rlv14992_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4f8b1bc-83c3-4819-9d98-9491df98d494"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0a0f7b08-80b8-4e40-9c1f-5305c35720f2"}}}}, {"uuid": "2d368127-8205-4442-9a21-37ee30d3f334", "name": "cab7b5f5-254d-4612-b29a-ee256010e346_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.667455481738122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8122169683202977, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f1435521-c53a-4628-ba0c-29fab58ef34f", "name": "424231c3-871e-42ab-b340-3810cde2a19c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2d368127-8205-4442-9a21-37ee30d3f334"}}}]}, {"uuid": "e519484b-3290-497d-8b32-be3a202acc1d", "name": "load_p1rlv15007_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc29de5b-3a3f-40c0-bde4-9a57f5f62b5c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f1435521-c53a-4628-ba0c-29fab58ef34f"}}}}, {"uuid": "af7b4c86-76f9-4a08-808b-3faf1fda48be", "name": "3dfb5887-53cb-4e9d-862f-0c648e2d0aae_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.667455481738122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8122169683202977, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "be2aac07-1e00-474e-a6c3-5451a234ac7d", "name": "633c8a6c-8ee7-43de-8e99-a75ffe5c6223", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "af7b4c86-76f9-4a08-808b-3faf1fda48be"}}}]}, {"uuid": "333f0478-984e-4add-baac-b5bded1c612d", "name": "load_p1rlv15007_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc29de5b-3a3f-40c0-bde4-9a57f5f62b5c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "be2aac07-1e00-474e-a6c3-5451a234ac7d"}}}}, {"uuid": "3b4a6592-f755-44ef-8cf2-2744c004d806", "name": "7df558ba-4f9b-4d05-802a-84fe6da2eba6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7847716543397305, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8567239737527961, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c10a1df-1289-4c5d-95cc-6ae363879d1b", "name": "f699cd67-9d6c-42de-af3e-3b5b25db4abf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3b4a6592-f755-44ef-8cf2-2744c004d806"}}}]}, {"uuid": "e796f84b-ec7a-4323-9053-423934ab8911", "name": "load_p1rlv15008_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19231152-1fd1-4e07-a5d9-603c765b2cae"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c10a1df-1289-4c5d-95cc-6ae363879d1b"}}}}, {"uuid": "155d9294-2026-4595-a10f-5d1d3370d942", "name": "d1ff1274-c897-4045-a6ab-1bc942556d49_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7847716543397305, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8567239737527961, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4cf1c416-9a98-4133-abfb-d14595d37519", "name": "58be0c17-d02f-4a51-81ea-eb67be621b58", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "155d9294-2026-4595-a10f-5d1d3370d942"}}}]}, {"uuid": "e4f20f75-2bf9-44b6-9665-9dcfd0831802", "name": "load_p1rlv15008_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19231152-1fd1-4e07-a5d9-603c765b2cae"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4cf1c416-9a98-4133-abfb-d14595d37519"}}}}, {"uuid": "88061b2d-03dd-4bef-b2aa-c5113d39db92", "name": "3d8d4048-7d53-47a2-9ff8-b98a7c5a734d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6848010607962993, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6615616037111118, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "33b2a2ec-137a-40da-bab7-0d9db8e29dba", "name": "2c8cc345-ec14-454c-a3df-7999de4b373e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "88061b2d-03dd-4bef-b2aa-c5113d39db92"}}}]}, {"uuid": "ef3cd349-73a6-4848-b20b-cdd1218fcd31", "name": "load_p1rlv15027_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07e3b847-cc9a-4f84-bc00-cb4396b6dea0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "33b2a2ec-137a-40da-bab7-0d9db8e29dba"}}}}, {"uuid": "0bb0048a-e1a5-4541-9c5b-7b1754279a93", "name": "36d9565b-932f-4eac-8928-c87b2db194cc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6848010607962993, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6615616037111118, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4010dd0f-be87-4210-ab11-20b47a6824f2", "name": "5a251cb6-cfea-45a4-a2ab-a30edaea99f1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0bb0048a-e1a5-4541-9c5b-7b1754279a93"}}}]}, {"uuid": "14061709-05d6-4809-a0fb-8de5dbb878c7", "name": "load_p1rlv15027_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07e3b847-cc9a-4f84-bc00-cb4396b6dea0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4010dd0f-be87-4210-ab11-20b47a6824f2"}}}}, {"uuid": "aa3ecebd-b7f6-453c-b107-f9de938836e8", "name": "18d1cbb6-315b-4ac8-8058-357d964badc0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.297417532176794, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2780703813036578, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "065b9b89-c7a5-42c6-a9ad-b1f750c56c53", "name": "23ed7327-4f19-48a3-b8ec-a1246c3101a3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aa3ecebd-b7f6-453c-b107-f9de938836e8"}}}]}, {"uuid": "abf89700-c23c-4f1f-9986-f9363dd66505", "name": "load_p1rlv15045_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "baccbdab-efc0-487d-b00d-38d3d4be57b4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "065b9b89-c7a5-42c6-a9ad-b1f750c56c53"}}}}, {"uuid": "e82a813c-40b1-4474-94ad-105922c9197a", "name": "be588434-76bf-42da-8db0-63712217a3ad_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.297417532176794, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2780703813036578, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6fdb5567-a8c7-45aa-9049-70c86ad648bf", "name": "892b9695-55fc-43ed-a900-4ad2df7299a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e82a813c-40b1-4474-94ad-105922c9197a"}}}]}, {"uuid": "5e9e9d33-d84f-422b-aec3-bd7049a99b07", "name": "load_p1rlv15045_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "baccbdab-efc0-487d-b00d-38d3d4be57b4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6fdb5567-a8c7-45aa-9049-70c86ad648bf"}}}}, {"uuid": "54f59e7b-dbde-4448-9adf-2c3b2b205aee", "name": "0d9b2913-0b05-4723-a677-45647949f9dd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3054635933061174, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.028189505661142127, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "35859e7f-0203-421f-b7e1-95a5d1f8bdad", "name": "5aabebba-312c-4cd1-9dcb-ab9c9f89edef", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "54f59e7b-dbde-4448-9adf-2c3b2b205aee"}}}]}, {"uuid": "7b61f36b-0fd8-4db1-8d5e-3bd2e69ded78", "name": "load_p1rlv15046_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2182c9fd-fd3d-4cb1-b525-192480823e2f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "35859e7f-0203-421f-b7e1-95a5d1f8bdad"}}}}, {"uuid": "d5da2654-9c5d-4151-b380-9a54ef5dff84", "name": "76b214c4-32dd-43ae-ae73-5a04d373e4c6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3054635933061174, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.028189505661142127, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fbcde39a-5be9-4ee4-a007-905fc48dd499", "name": "6d9364c1-db81-416b-bf4a-944575d28809", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d5da2654-9c5d-4151-b380-9a54ef5dff84"}}}]}, {"uuid": "c8817eda-96ee-4de0-974b-5a4ee8e2d700", "name": "load_p1rlv15046_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2182c9fd-fd3d-4cb1-b525-192480823e2f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fbcde39a-5be9-4ee4-a007-905fc48dd499"}}}}, {"uuid": "0ed66465-c93e-4bbc-b6d8-f8733570df59", "name": "d483b59c-359c-4b8a-b4ee-4bd199f54e33_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.605318582042619, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.38786447308176675, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82256a60-b4fc-44df-9a90-638422679924", "name": "019726b9-c3ea-4490-adab-f9f7dd742641", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0ed66465-c93e-4bbc-b6d8-f8733570df59"}}}]}, {"uuid": "399a3df4-6083-444d-9d10-92ade5bb7bbe", "name": "load_p1rlv15056_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a914ec3a-4883-42a7-b25d-133a1410b8d9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "82256a60-b4fc-44df-9a90-638422679924"}}}}, {"uuid": "f7a4e74b-d00d-493e-8ed3-48318ab6318d", "name": "74a33022-3750-4c48-9101-1b0b94dab6ab_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.605318582042619, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.38786447308176675, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5833379c-cf4a-404e-bc1f-c2005aa40cef", "name": "ddac8155-a00a-4162-849f-c9787c308814", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f7a4e74b-d00d-493e-8ed3-48318ab6318d"}}}]}, {"uuid": "e2c58061-9dbe-45ce-a721-8992f3b96cae", "name": "load_p1rlv15056_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a914ec3a-4883-42a7-b25d-133a1410b8d9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5833379c-cf4a-404e-bc1f-c2005aa40cef"}}}}, {"uuid": "084827a7-20ea-4302-b255-ff892f846062", "name": "45eed0da-500b-4355-8d8b-3fa3d64c28b7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.038374933892965, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6403266957226059, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c1901508-d644-40b5-af80-37c5ad1ef045", "name": "35ff5b24-e1f4-4870-8339-b09c76f3720c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "084827a7-20ea-4302-b255-ff892f846062"}}}]}, {"uuid": "3f51b6de-6dd3-4676-bb1e-e6b39419098e", "name": "load_p1rlv15064_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "366c9c98-59f1-46d5-b39c-4046703e5e4b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c1901508-d644-40b5-af80-37c5ad1ef045"}}}}, {"uuid": "5e1dd03d-0244-4a37-81c9-224edc02ae81", "name": "ee724805-ca62-43cc-b825-61971b140f9f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.038374933892965, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6403266957226059, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e51d4f22-e74d-40ed-b32e-1e608c2e9942", "name": "7e215efb-c2fa-4670-a122-ab9e908d23c0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5e1dd03d-0244-4a37-81c9-224edc02ae81"}}}]}, {"uuid": "85803038-b368-41b8-a135-3e5c87d7c73e", "name": "load_p1rlv15064_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "366c9c98-59f1-46d5-b39c-4046703e5e4b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e51d4f22-e74d-40ed-b32e-1e608c2e9942"}}}}, {"uuid": "7ef14852-87ee-49f6-a01e-3b2f0d54d045", "name": "7764dae3-4df1-4ec9-a275-9586e0c11678_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5369480608064634, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2969034126636569, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "392c267e-bbf0-4ebf-9128-1bb9f19f45c2", "name": "0e554282-ef8b-4bd7-9f95-bd3134747501", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7ef14852-87ee-49f6-a01e-3b2f0d54d045"}}}]}, {"uuid": "4c962874-3ff5-4ffd-9a2e-03dd51d5caa5", "name": "load_p1rlv15082_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a56b9ad8-c53b-4652-bf94-a7a7dfb8b306"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "392c267e-bbf0-4ebf-9128-1bb9f19f45c2"}}}}, {"uuid": "afd3dd67-a714-44d8-b648-025a873bcc66", "name": "9e168c79-e6f8-46e4-9b5f-308d69d2a3de_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5369480608064634, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2969034126636569, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d78aa811-e5de-47d2-8a6e-ca859e6d274d", "name": "8ffaefe2-8f9b-40ee-8efb-997d246a6f78", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "afd3dd67-a714-44d8-b648-025a873bcc66"}}}]}, {"uuid": "0e534536-98df-4d0e-a2b2-c57f662230ad", "name": "load_p1rlv15082_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a56b9ad8-c53b-4652-bf94-a7a7dfb8b306"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d78aa811-e5de-47d2-8a6e-ca859e6d274d"}}}}, {"uuid": "8a16342a-f4dc-49bc-a03d-0b6ef94b5c8a", "name": "2ee01cca-a911-4d27-b1f1-32145c9f8a0b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.694404982351279, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0468171481890831, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dce3bd76-dd92-4a29-bdae-8f511f6a66de", "name": "1ab69093-721c-4b03-a875-566ccccd6991", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a16342a-f4dc-49bc-a03d-0b6ef94b5c8a"}}}]}, {"uuid": "3ea19cfb-febf-4c3e-834f-4bb5374952c5", "name": "load_p1rlv15109_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "161d4e7b-30f2-447c-a369-1bfa3ba2cd70"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dce3bd76-dd92-4a29-bdae-8f511f6a66de"}}}}, {"uuid": "16f16d5b-6d41-4e21-8374-2b49c353e3ae", "name": "9ffa5173-e5de-4d02-98a8-40351f2d63c0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.694404982351279, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0468171481890831, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f06eae7f-b1db-45c7-8ec8-81018096d1ed", "name": "fc22c1f4-36ec-4c93-83d8-52906a7c3b5c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "16f16d5b-6d41-4e21-8374-2b49c353e3ae"}}}]}, {"uuid": "77da50e4-307b-46ce-9a51-879e6dc63b3e", "name": "load_p1rlv15109_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "161d4e7b-30f2-447c-a369-1bfa3ba2cd70"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f06eae7f-b1db-45c7-8ec8-81018096d1ed"}}}}, {"uuid": "31580ad3-7e99-4aa5-8204-f7f827d1ba17", "name": "451c0e75-b2d5-42a5-a87a-b70884307d2f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9518333270985427, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3340330193202704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "643ee3e6-5e93-441a-adb3-a7e109757722", "name": "e1085673-f52e-4199-b3d0-537d5669de47", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "31580ad3-7e99-4aa5-8204-f7f827d1ba17"}}}]}, {"uuid": "4370f7f8-8420-4bbe-a500-4e4c6f80e0ae", "name": "load_p1rlv15125_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb6d8f13-f04e-4b80-a8dc-e16af1dc860e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "643ee3e6-5e93-441a-adb3-a7e109757722"}}}}, {"uuid": "a85898a5-2e15-440e-b099-8b28ced7c56d", "name": "0308184c-c1ca-4b58-a025-7bfc339d1646_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9518333270985427, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3340330193202704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e72c23e9-be35-479c-b4ad-f19d089ff9f0", "name": "923523d9-abbf-4aa6-b18c-e9c265f73f11", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a85898a5-2e15-440e-b099-8b28ced7c56d"}}}]}, {"uuid": "b13aabec-dc96-44ec-aaeb-f00a782ba1b1", "name": "load_p1rlv15125_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb6d8f13-f04e-4b80-a8dc-e16af1dc860e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e72c23e9-be35-479c-b4ad-f19d089ff9f0"}}}}, {"uuid": "367fdd34-4284-448b-9b5b-14e8c663b7f4", "name": "87f0776a-0237-453d-ad1f-4eb39b4fea02_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.386602840079273, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.360256050049383, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "59541744-25fc-4a62-85f1-6fd5a167211e", "name": "df98da5e-a000-4aa1-873a-297a7e9fd7f6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "367fdd34-4284-448b-9b5b-14e8c663b7f4"}}}]}, {"uuid": "5ed7c0aa-1d90-4cb5-b068-f3bde5ccae4f", "name": "load_p1rlv15163_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdee6d84-9253-4fba-b713-3e41d706e999"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "59541744-25fc-4a62-85f1-6fd5a167211e"}}}}, {"uuid": "6a34efdc-e3cc-45b7-a203-7bf5b2c81eb8", "name": "5786607c-5f81-40a4-889f-ee57750faeb2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.386602840079273, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.360256050049383, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4f3a6f0a-3726-4ff0-9e98-0f1b860ef874", "name": "c46c090a-58bb-49eb-b6be-1396413b297f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6a34efdc-e3cc-45b7-a203-7bf5b2c81eb8"}}}]}, {"uuid": "ba90f2b2-b807-4a1a-b4d7-7610eb475222", "name": "load_p1rlv15163_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdee6d84-9253-4fba-b713-3e41d706e999"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4f3a6f0a-3726-4ff0-9e98-0f1b860ef874"}}}}, {"uuid": "0a6bd41f-0854-469a-bfba-2a896c3a06cd", "name": "2ff222e2-6676-45cd-91b2-7c319b22d5eb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0472938281946713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.40441110210881914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "94810cc7-42eb-448b-86bf-3e77db5adbf2", "name": "12e0771d-de5e-44a2-bf41-a3380bdb0e0b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0a6bd41f-0854-469a-bfba-2a896c3a06cd"}}}]}, {"uuid": "f4cdda81-b2ef-465c-a7ad-ab4debb3e111", "name": "load_p1rlv15170_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d2f8fcb-c279-49d5-88be-39e6a1d1990b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "94810cc7-42eb-448b-86bf-3e77db5adbf2"}}}}, {"uuid": "6ea36083-ee4d-4b49-a387-e7ffb21a84d3", "name": "e38edbdf-acca-456f-9f26-475bd1e7d4ca_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0472938281946713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.40441110210881914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7698473e-55ad-4675-ab96-c68f73e202f5", "name": "f10da870-1a98-4f9d-afa0-1508d9e6ff83", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6ea36083-ee4d-4b49-a387-e7ffb21a84d3"}}}]}, {"uuid": "f5153213-5736-4896-bac5-e95ec3efd810", "name": "load_p1rlv15170_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d2f8fcb-c279-49d5-88be-39e6a1d1990b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7698473e-55ad-4675-ab96-c68f73e202f5"}}}}, {"uuid": "f59209e3-2b75-467b-bf26-981f82c0e69f", "name": "70a64c03-6187-4053-b7cb-e3b2c5bf19e7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.664483224984605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9538644530515166, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "856d1ccc-4a6d-4801-8277-40e6862d50d0", "name": "5f63d5f7-f371-4ccf-9779-492f8bb8b7bc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f59209e3-2b75-467b-bf26-981f82c0e69f"}}}]}, {"uuid": "c2829c3c-272c-4006-ac8d-2617e0370e62", "name": "load_p1rlv15171_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc7cd505-823c-49bb-9e49-3681267dbef0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "856d1ccc-4a6d-4801-8277-40e6862d50d0"}}}}, {"uuid": "d051dd30-ae89-4c67-bd43-6fc4bedd9e0a", "name": "9178c9dd-5219-4698-8f52-aff2f22d2a89_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.664483224984605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9538644530515166, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "122d26a5-f9de-45b9-9ceb-b225d56dc0a6", "name": "f07b5511-be53-44ef-a699-ffefe90618e7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d051dd30-ae89-4c67-bd43-6fc4bedd9e0a"}}}]}, {"uuid": "e9c8b1e2-fa10-41aa-b5e8-0d968a4089c8", "name": "load_p1rlv15171_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc7cd505-823c-49bb-9e49-3681267dbef0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "122d26a5-f9de-45b9-9ceb-b225d56dc0a6"}}}}, {"uuid": "cf9ef428-0e5a-41c0-9c22-c7f3d850f628", "name": "eb19f670-a0bc-4be3-b2a4-fddbb14459d8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.13715702476687, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3795210711832634, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6d52cec0-b460-40fd-81ac-984c9828e283", "name": "5c25944f-08e8-4657-bb47-4a19930fa56b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cf9ef428-0e5a-41c0-9c22-c7f3d850f628"}}}]}, {"uuid": "97641359-1a44-4cd8-bf51-68f7244a794f", "name": "load_p1rlv15180_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e218b01d-f713-4baf-9688-7e77ea413c8c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6d52cec0-b460-40fd-81ac-984c9828e283"}}}}, {"uuid": "0b591a3e-599f-4ac2-ba18-13d14f36399b", "name": "097eb900-2025-4532-bd56-c5e7a836dfd5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.13715702476687, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3795210711832634, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eb3821c5-b7f6-4dc7-a87d-0f997549dd8f", "name": "b2d3304c-0cd9-4650-98f7-ad3323236733", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0b591a3e-599f-4ac2-ba18-13d14f36399b"}}}]}, {"uuid": "80234a72-b646-458d-abc5-b1b670dfbea6", "name": "load_p1rlv15180_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e218b01d-f713-4baf-9688-7e77ea413c8c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eb3821c5-b7f6-4dc7-a87d-0f997549dd8f"}}}}, {"uuid": "ed6adb50-d2ca-49e7-a0af-b3b711ba22b9", "name": "48cad7ff-4b21-496f-9b7e-9111795dc989_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3ad66fff-9252-46e1-b701-234b54d06850", "name": "48cad7ff-4b21-496f-9b7e-9111795dc989_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "489a8e34-f115-4e1f-ba31-2e6c13f264dc", "name": "48cad7ff-4b21-496f-9b7e-9111795dc989_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2222dae9-b9d5-49d4-aa6d-52ccb4e86ffc", "name": "5a1590d8-ac99-4377-8c29-883964d907e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ed6adb50-d2ca-49e7-a0af-b3b711ba22b9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3ad66fff-9252-46e1-b701-234b54d06850"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "489a8e34-f115-4e1f-ba31-2e6c13f264dc"}}}]}, {"uuid": "e5e211ef-445f-464a-84c5-1d7868cc3b32", "name": "load_p1rlv15196", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64634ab5-a5b0-45ae-9763-7d0be029350f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2222dae9-b9d5-49d4-aa6d-52ccb4e86ffc"}}}}, {"uuid": "4f307380-46d3-47c5-bba9-20e079c512ef", "name": "e6b472bb-8ae6-4320-a7b4-b9e96dd4c826_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4727091425662127, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8266013407121705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b8d65bc3-6366-42e6-ac9e-caccf2d56ab6", "name": "d51de9e1-d937-49e5-aae4-012dc576d5af", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4f307380-46d3-47c5-bba9-20e079c512ef"}}}]}, {"uuid": "ddbe7663-6055-4269-bf3f-4f47ab59854f", "name": "load_p1rlv15197_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80a74c6f-c9ec-4742-8fce-ad73c0a6c459"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b8d65bc3-6366-42e6-ac9e-caccf2d56ab6"}}}}, {"uuid": "05ade002-e5e3-4957-983a-7f25931b4b86", "name": "c243d62d-2a4c-4ae1-a4e4-14354d15208b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4727091425662127, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8266013407121705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ca6a98e8-6a77-4566-8bdf-e2588884c9ff", "name": "a28bcc36-e94a-4c0d-9c1d-7c39e9077f4c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "05ade002-e5e3-4957-983a-7f25931b4b86"}}}]}, {"uuid": "774fbd6f-5d4f-41c7-9763-5dd3326edeb4", "name": "load_p1rlv15197_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80a74c6f-c9ec-4742-8fce-ad73c0a6c459"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ca6a98e8-6a77-4566-8bdf-e2588884c9ff"}}}}, {"uuid": "1a64cd3e-a5e7-4c88-a5c9-6a434d68f282", "name": "99fafce9-bcbf-4dbf-b1ea-efde3eec11e6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0052757727111112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4127143879372469, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "53d4034f-4912-4542-8654-099b40e784aa", "name": "c1de5b63-1ec2-43b6-a095-e8a2bd069689", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1a64cd3e-a5e7-4c88-a5c9-6a434d68f282"}}}]}, {"uuid": "14b42caf-a810-40b6-8ce9-ecf6b5736e12", "name": "load_p1rlv15394_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd21ae8b-7841-43b4-871f-316c4b8b4cd2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "53d4034f-4912-4542-8654-099b40e784aa"}}}}, {"uuid": "aaf24261-ff1e-401a-8dc7-a40cd8c20954", "name": "fde98af1-a25f-4925-abb1-965c61a64a24_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0052757727111112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4127143879372469, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "93905f3d-11ae-48b8-a283-dbb7b338bb5e", "name": "b1a83f36-c226-4a2c-a50f-aff46bc2b790", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aaf24261-ff1e-401a-8dc7-a40cd8c20954"}}}]}, {"uuid": "128c9748-eb61-41b0-982c-2c4247dfc49e", "name": "load_p1rlv15394_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd21ae8b-7841-43b4-871f-316c4b8b4cd2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "93905f3d-11ae-48b8-a283-dbb7b338bb5e"}}}}, {"uuid": "992cfd71-f12f-4830-9dec-091fa7812f7d", "name": "7f690059-902d-4fb4-a079-c3235de18eb5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2767849318619047, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.48605417385422345, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "442d77e5-1dca-4571-a3e5-ac4e43a550ed", "name": "1f87872c-f748-4725-a7ea-bceb11b82b15", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "992cfd71-f12f-4830-9dec-091fa7812f7d"}}}]}, {"uuid": "934e91ae-163b-4971-abd3-a22c61cc0d93", "name": "load_p1rlv15399_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ec1f313-f341-498c-b1c2-6669b1cbc629"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "442d77e5-1dca-4571-a3e5-ac4e43a550ed"}}}}, {"uuid": "9248525f-1675-4fc4-9811-af7fd9d4f41c", "name": "3e590369-cf2f-4e43-9c1e-24d74b8f9b9f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2767849318619047, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.48605417385422345, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0b2184b1-a104-41e6-9370-e2099151cc50", "name": "9a3c549e-db8d-45ca-b44e-ec1e12111b3c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9248525f-1675-4fc4-9811-af7fd9d4f41c"}}}]}, {"uuid": "191ea403-3045-4b32-a91f-e399b4afbde0", "name": "load_p1rlv15399_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ec1f313-f341-498c-b1c2-6669b1cbc629"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0b2184b1-a104-41e6-9370-e2099151cc50"}}}}, {"uuid": "f63f659e-6f78-4805-890a-ab555465155b", "name": "0f710b31-0344-4368-9937-9c8df3e60cde_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.962031206451152, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.4366749645571537, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5c0485ab-103f-4e09-adac-9ea1fd468772", "name": "2f07204f-afcd-4e4f-a142-362e75288834", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f63f659e-6f78-4805-890a-ab555465155b"}}}]}, {"uuid": "c089d7eb-49d0-4147-a56e-a1d180a82959", "name": "load_p1rlv15418_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9ca373a-b1c3-464d-bbe3-c05b728beb30"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5c0485ab-103f-4e09-adac-9ea1fd468772"}}}}, {"uuid": "7acbdd19-a91c-419d-b26e-0dfa678951c5", "name": "1095f810-19fd-4e77-acf7-75afaf7eda5e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.962031206451152, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.4366749645571537, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "441f6f39-d3fa-4365-a20e-46ad21d3c6e2", "name": "2e040e4d-bf95-4452-b67f-8367ad8815a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7acbdd19-a91c-419d-b26e-0dfa678951c5"}}}]}, {"uuid": "c713637f-bc7f-4b41-9a3a-30c148f5104e", "name": "load_p1rlv15418_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9ca373a-b1c3-464d-bbe3-c05b728beb30"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "441f6f39-d3fa-4365-a20e-46ad21d3c6e2"}}}}, {"uuid": "d3a9d3fd-1a34-44e4-8200-eee0a284acb4", "name": "b74939b1-fd6e-4f11-8c62-f7dc92cabb82_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.365256087534968, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9406994095530364, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2373d602-d50f-45db-9d74-e71e15007f0e", "name": "2292044b-f6fb-4e61-9d67-9be2743fc8fc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d3a9d3fd-1a34-44e4-8200-eee0a284acb4"}}}]}, {"uuid": "20a84130-1e07-46c3-a786-3c298f7ca770", "name": "load_p1rlv15419_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8bc46399-0276-4ae7-aa8b-4cdd3d3555e8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2373d602-d50f-45db-9d74-e71e15007f0e"}}}}, {"uuid": "f27afbe4-10a3-4ac5-ade2-6bbdd2efb2b0", "name": "cfbae373-28f1-4fdc-ba91-f768f9d0da3f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.365256087534968, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9406994095530364, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ae825d0a-d7ce-4115-ae2e-a1da6ac61fc6", "name": "eded9cdc-5c13-460c-9134-1d7e65e17b67", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f27afbe4-10a3-4ac5-ade2-6bbdd2efb2b0"}}}]}, {"uuid": "be3c7974-aaf8-4b57-9b76-b60866b6f18b", "name": "load_p1rlv15419_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8bc46399-0276-4ae7-aa8b-4cdd3d3555e8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ae825d0a-d7ce-4115-ae2e-a1da6ac61fc6"}}}}, {"uuid": "16476ff1-9623-445d-bc5e-aaa6a2b810a5", "name": "7194d1ad-2e55-4e2b-b643-bb700216f4cb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e1d8e8c1-34c8-4b1c-b9e1-b84b5bbb3cfc", "name": "3a932951-92ce-4fbc-85c0-2c5bcdd3ef0e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "16476ff1-9623-445d-bc5e-aaa6a2b810a5"}}}]}, {"uuid": "ac52531c-a55e-4bf0-b5d2-4d084bb9e315", "name": "load_p1rlv15423_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26009a7e-9bfc-4967-af28-4d8937539eb1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e1d8e8c1-34c8-4b1c-b9e1-b84b5bbb3cfc"}}}}, {"uuid": "c486cd31-8e17-47ee-961e-aec42080087a", "name": "ea850e56-120c-4fac-a9cc-4cddaf1d3bb5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "44f1561b-29cb-47ea-a612-238ac8057242", "name": "187a98ff-7ce4-48b4-a14c-4c538f2bd4eb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c486cd31-8e17-47ee-961e-aec42080087a"}}}]}, {"uuid": "e4273425-20a2-41e6-954c-5ab2df4e2a7a", "name": "load_p1rlv15423_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26009a7e-9bfc-4967-af28-4d8937539eb1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "44f1561b-29cb-47ea-a612-238ac8057242"}}}}, {"uuid": "dbcddb3b-e55f-4b76-9fcf-1d9114e1a182", "name": "f9f528d9-9744-4621-bbec-785f15cc7011_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7411160800233395, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1601349573814363, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "233a1839-ef2e-4e0a-8020-9cb19c9c05ea", "name": "59c9eeb9-e4a9-4356-953a-d0ec6c056115", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dbcddb3b-e55f-4b76-9fcf-1d9114e1a182"}}}]}, {"uuid": "5fc4312b-569e-4e54-b8d5-a8c5e7e0f957", "name": "load_p1rlv15466_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "544be417-0db6-45a7-8314-ec40944781fa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "233a1839-ef2e-4e0a-8020-9cb19c9c05ea"}}}}, {"uuid": "9611ddc9-264a-4100-afb5-47f14ffa366d", "name": "8eb7a877-fc86-45d3-ad46-dff8762e76c8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7411160800233395, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1601349573814363, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "49e70e43-82bf-4626-a209-25e0c3b241f4", "name": "c5532ae5-59cd-4da1-8f85-47d57292a6ea", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9611ddc9-264a-4100-afb5-47f14ffa366d"}}}]}, {"uuid": "bd4cd469-9871-4f86-aa59-8c4c8eeb4afe", "name": "load_p1rlv15466_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "544be417-0db6-45a7-8314-ec40944781fa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "49e70e43-82bf-4626-a209-25e0c3b241f4"}}}}, {"uuid": "9ddeff1c-1865-47b5-9a20-6f4480f52a6a", "name": "74631308-8cae-47cc-9953-c2d80336a11f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7411160800233395, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1601349573814363, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c2945fa0-ff8a-4d7f-8392-1840ea3e35d1", "name": "0c493fbc-aa14-4ae8-951e-aa0d4692833d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9ddeff1c-1865-47b5-9a20-6f4480f52a6a"}}}]}, {"uuid": "1ada6dce-48f3-4868-a6f9-c9413cb6bba8", "name": "load_p1rlv15474_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34e0ffc2-da17-441b-bd4d-26d5a1104712"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c2945fa0-ff8a-4d7f-8392-1840ea3e35d1"}}}}, {"uuid": "0f3eb859-0b60-4406-bf90-21daf8463516", "name": "cb2f7f14-4b4f-4142-ab3d-d86c1f877024_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7411160800233395, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1601349573814363, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5a9977ae-9a9b-4938-9b27-cc4a50d6a106", "name": "d7c4b4ea-d122-4f14-86d5-d8b00795d057", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0f3eb859-0b60-4406-bf90-21daf8463516"}}}]}, {"uuid": "4d230c80-1c74-4403-ac4b-a51751d36efe", "name": "load_p1rlv15474_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34e0ffc2-da17-441b-bd4d-26d5a1104712"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5a9977ae-9a9b-4938-9b27-cc4a50d6a106"}}}}, {"uuid": "bde46da1-4eb0-4327-a607-f4125b62957e", "name": "b4ab7e8c-1e80-4c6d-8097-271037e152d5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.84153235443771, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.447226409705929, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c721f5cd-7665-48e9-822b-b643ca760c4c", "name": "b1002f59-669b-4a7a-b223-b0ce571d42ed", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bde46da1-4eb0-4327-a607-f4125b62957e"}}}]}, {"uuid": "a6d4f5dd-727d-412a-acf1-c047ac85db94", "name": "load_p1rlv15478_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "335df4da-50d2-4fbe-a271-ac04257d35c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c721f5cd-7665-48e9-822b-b643ca760c4c"}}}}, {"uuid": "7b1ce745-357c-4b01-aa87-985d6a6d93ef", "name": "130d584d-ee27-4cf0-b7f9-a354626a372c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.84153235443771, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.447226409705929, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cecd57ee-2d04-4090-8ab6-96fb8a32602c", "name": "d1c5099b-ce74-4f1a-beee-013966dd559c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b1ce745-357c-4b01-aa87-985d6a6d93ef"}}}]}, {"uuid": "5610562d-4d19-4e4b-96d9-2e6f54c7a8d1", "name": "load_p1rlv15478_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "335df4da-50d2-4fbe-a271-ac04257d35c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cecd57ee-2d04-4090-8ab6-96fb8a32602c"}}}}, {"uuid": "10d4058c-cc51-4884-8918-3eabe6c30d8f", "name": "5c33781b-3404-4773-8418-6f4559d102a7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6639c955-f5ea-4a95-8885-340171b23e94", "name": "bc182204-578a-4009-9d2a-53d116b4eb8a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "10d4058c-cc51-4884-8918-3eabe6c30d8f"}}}]}, {"uuid": "339cf270-76e3-42a4-8e2a-30f9527fc3cf", "name": "load_p1rlv15483_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c4e3eac-0b1a-4feb-b39f-079c6d2c1d82"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6639c955-f5ea-4a95-8885-340171b23e94"}}}}, {"uuid": "02eec10f-baad-4d72-8fd2-adfd32006494", "name": "232ddfb9-0f86-4bb7-9e22-c382d8cbeca8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "270f4f58-9952-408d-8edf-87be15ede35d", "name": "24482191-182f-4110-8be8-9af3853180fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "02eec10f-baad-4d72-8fd2-adfd32006494"}}}]}, {"uuid": "5c1376af-a293-4081-a620-91d404fa10f0", "name": "load_p1rlv15483_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c4e3eac-0b1a-4feb-b39f-079c6d2c1d82"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "270f4f58-9952-408d-8edf-87be15ede35d"}}}}, {"uuid": "4d9460f9-f8ea-45a4-a8d8-d4823488d408", "name": "f20cdf6d-fab2-4571-a162-b620ee122f03_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "45439d97-58ce-42f2-bec5-c7b74da13429", "name": "25743876-2804-4dfe-96a3-9e9f6cfed976", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4d9460f9-f8ea-45a4-a8d8-d4823488d408"}}}]}, {"uuid": "5fa72b88-1b29-4b26-a54d-c967ea3e6cd2", "name": "load_p1rlv15484_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6749066f-4739-41ec-8369-8da49dd9e1c8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "45439d97-58ce-42f2-bec5-c7b74da13429"}}}}, {"uuid": "94c50990-e8f0-40b8-a2de-e85f1cdc0cb3", "name": "8257838d-9cc7-4b87-99c8-b8116910d4d4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6ae8cefd-e967-4b54-a346-a5c769ef7a4a", "name": "f817426f-5b7e-4fbc-93b5-7a4f97bf6835", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "94c50990-e8f0-40b8-a2de-e85f1cdc0cb3"}}}]}, {"uuid": "3801303e-0611-4e7b-b70a-2ae965aa8ee3", "name": "load_p1rlv15484_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6749066f-4739-41ec-8369-8da49dd9e1c8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6ae8cefd-e967-4b54-a346-a5c769ef7a4a"}}}}, {"uuid": "2a510bae-755d-43de-b23b-ab8993ce13df", "name": "a8d69f35-1632-45b7-8cd5-541ffa86e572_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5041010955030301, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21577690333785765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "14f155fe-c1f1-44d3-99b0-b99ce0157e64", "name": "8b9a313a-c161-41b2-9dc5-5decb4da3eca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2a510bae-755d-43de-b23b-ab8993ce13df"}}}]}, {"uuid": "6fb69007-5eb9-4a48-9d3b-b7e35932f1b2", "name": "load_p1rlv15487_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "921f8f54-ff83-4d2f-8bf4-ee80bab64ce8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "14f155fe-c1f1-44d3-99b0-b99ce0157e64"}}}}, {"uuid": "bb7f3243-53f3-4af8-901c-e5b6688d9085", "name": "f413b114-08d9-4268-9af4-1a112227dab0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5041010955030301, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21577690333785765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "09e7c2bd-e5e6-47a5-89ee-c10bc7fa7efd", "name": "8d2c276d-6085-4e57-9f7e-cad935bc1bae", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bb7f3243-53f3-4af8-901c-e5b6688d9085"}}}]}, {"uuid": "2f9dfbab-cc48-4d6e-a657-2522ba676563", "name": "load_p1rlv15487_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "921f8f54-ff83-4d2f-8bf4-ee80bab64ce8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "09e7c2bd-e5e6-47a5-89ee-c10bc7fa7efd"}}}}, {"uuid": "4c5a3559-3711-4630-a2cb-1f593c502807", "name": "b30379a4-c9c8-4d1e-a238-a2c504c90b8b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7909002853206712, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1704468602852825, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a291a66b-7b02-4c1e-88d4-80d6f3907695", "name": "10fd141f-c5e0-4494-a3d7-1509990cdf8d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4c5a3559-3711-4630-a2cb-1f593c502807"}}}]}, {"uuid": "e4e71f45-134a-4075-b697-9d222843e30d", "name": "load_p1rlv15488_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6579cc93-2b08-4010-816d-3bef509000cd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a291a66b-7b02-4c1e-88d4-80d6f3907695"}}}}, {"uuid": "3d218d4b-6589-4683-9d50-4f072cf955f9", "name": "a46442de-50e9-4cb2-8bd5-76f12638c054_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7909002853206712, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1704468602852825, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "273f8495-5041-4d50-be86-c5df21cf1202", "name": "e814b988-a237-4f36-a2e0-9eca92db73a3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3d218d4b-6589-4683-9d50-4f072cf955f9"}}}]}, {"uuid": "8ad3ab49-7155-403f-8f7a-db1c665052f7", "name": "load_p1rlv15488_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6579cc93-2b08-4010-816d-3bef509000cd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "273f8495-5041-4d50-be86-c5df21cf1202"}}}}, {"uuid": "9ddaceec-25b1-4e2f-97fe-e0f3bda9eab1", "name": "45abe17e-911f-4a38-90ef-29bf9a2995e1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4163439957648214, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5697938312046736, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f807423-4bcf-462f-9765-e7afcb199c02", "name": "9d8d17ff-60b3-450b-9fa9-181929912aa2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9ddaceec-25b1-4e2f-97fe-e0f3bda9eab1"}}}]}, {"uuid": "b693eeb6-80f6-474f-a21a-04fd615fc669", "name": "load_p1rlv15523_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37ccfa64-1373-49b2-85f6-279abea3c945"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f807423-4bcf-462f-9765-e7afcb199c02"}}}}, {"uuid": "b680a583-c323-4b66-8846-9e0cb1692ee2", "name": "241c0c4f-891a-4ae2-8bd9-8f4b17b2df31_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4163439957648214, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5697938312046736, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "88ae3fc4-dee9-4abb-b7cd-9f1c0c9a2e73", "name": "6b3d4b15-8bbc-4566-bfcc-58aef5610e62", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b680a583-c323-4b66-8846-9e0cb1692ee2"}}}]}, {"uuid": "5ab1fe3e-972c-4829-a87c-bab6ec203b43", "name": "load_p1rlv15523_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37ccfa64-1373-49b2-85f6-279abea3c945"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "88ae3fc4-dee9-4abb-b7cd-9f1c0c9a2e73"}}}}, {"uuid": "bcff2667-a612-43db-b611-5390a5c76156", "name": "896c245a-fddc-4280-b962-53dc8c8b7a65_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2037641724563426, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8275766375494601, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "64635c39-be3f-42a4-b66f-6e623db59e30", "name": "1b4a8ece-7618-47d6-a6ca-d72ab84ae452", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bcff2667-a612-43db-b611-5390a5c76156"}}}]}, {"uuid": "7a60fee1-177c-4473-bb96-ec8044cd167e", "name": "load_p1rlv15525_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6eec860d-08cf-4690-93e6-d909429d363d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "64635c39-be3f-42a4-b66f-6e623db59e30"}}}}, {"uuid": "a56079a2-f22d-4a10-9c2b-2a5a03e028d1", "name": "3353557b-0762-4889-a95f-cbbe120e2d22_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2037641724563426, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8275766375494601, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f5c77b29-b8ef-416b-bd23-ded5d646be5d", "name": "c72c9697-395f-4e8e-8c22-f88adb1c4dbc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a56079a2-f22d-4a10-9c2b-2a5a03e028d1"}}}]}, {"uuid": "ea9b4f68-5e35-439b-a1a2-820e07a5e96b", "name": "load_p1rlv15525_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6eec860d-08cf-4690-93e6-d909429d363d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f5c77b29-b8ef-416b-bd23-ded5d646be5d"}}}}, {"uuid": "f4cd6ac1-0942-444e-a0a8-7c10cdce52b3", "name": "280a77ec-ddcc-443d-993b-a39b278f4390_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.679689620441751, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9077324041357607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "80f4e690-25c1-4a86-87f6-54781fcab371", "name": "b0b7c20a-83e7-4f0c-8716-e548fb66a9f5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f4cd6ac1-0942-444e-a0a8-7c10cdce52b3"}}}]}, {"uuid": "91886b57-b270-4644-aaee-be8a5767e737", "name": "load_p1rlv15542_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b09822b3-a220-48ff-ad4f-62fca602f8b6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "80f4e690-25c1-4a86-87f6-54781fcab371"}}}}, {"uuid": "602a35b7-dba3-42fb-8c10-66468760c864", "name": "ffe9df7b-cc38-4e0f-b2c5-46dff8650db3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.679689620441751, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9077324041357607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c0697a93-163a-4601-81ad-de35e394789c", "name": "455cb216-13e7-48e4-aba4-19da4d9e19cf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "602a35b7-dba3-42fb-8c10-66468760c864"}}}]}, {"uuid": "50d02109-4fa7-425c-b1ec-cf5ea46ed546", "name": "load_p1rlv15542_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b09822b3-a220-48ff-ad4f-62fca602f8b6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c0697a93-163a-4601-81ad-de35e394789c"}}}}, {"uuid": "b5b2ec6f-7406-4e8c-8117-e3743b7aab68", "name": "e5ce500f-b8f4-4f7b-ba76-4a77731bf6f3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7539305984890898, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4187015133753737, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bfce76b1-d370-4fd8-a7f4-a3a9b2e2ce59", "name": "8934b0b2-50fc-4d11-bcbf-0a7501b30eea", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5b2ec6f-7406-4e8c-8117-e3743b7aab68"}}}]}, {"uuid": "e9e2fd04-1682-4241-8f34-246164c32690", "name": "load_p1rlv15603_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "688da57a-6f10-4ef8-8763-202a88c3a495"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bfce76b1-d370-4fd8-a7f4-a3a9b2e2ce59"}}}}, {"uuid": "42e70254-ef9d-47f3-9073-ef5f07401849", "name": "893cabcb-4969-4b8d-910c-775e1f80c569_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7539305984890898, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4187015133753737, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9d85ee74-4d56-475d-8d7d-6a212fd7253b", "name": "e3947cd9-083b-421a-8219-af7133a189fd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "42e70254-ef9d-47f3-9073-ef5f07401849"}}}]}, {"uuid": "67f7ca6b-7c11-434c-8855-4784b10b10f6", "name": "load_p1rlv15603_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "688da57a-6f10-4ef8-8763-202a88c3a495"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9d85ee74-4d56-475d-8d7d-6a212fd7253b"}}}}, {"uuid": "6ffcd115-2598-4bac-bcfc-fb62b8aa15e3", "name": "ad64bf0d-2411-4167-9270-bbf569eec871_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.69722938823788, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6546008506549251, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5bd3bed4-f868-4755-a420-30d0862d64e3", "name": "4be4563f-baab-4b66-a639-dae8729f5310", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6ffcd115-2598-4bac-bcfc-fb62b8aa15e3"}}}]}, {"uuid": "ba1acbf2-320f-4439-a3a9-058703243ea8", "name": "load_p1rlv15606_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c32ce070-e690-4fc1-92ac-f857691de578"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5bd3bed4-f868-4755-a420-30d0862d64e3"}}}}, {"uuid": "f0b37315-8176-4bcd-9b23-2b6f1208dd34", "name": "5ea4e10e-9355-47fc-aefc-ca29575c354e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.69722938823788, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6546008506549251, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e5cbc980-da5d-4976-8239-da70f4814fb8", "name": "38104937-5235-4578-9a80-ed28ecf1f1e0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f0b37315-8176-4bcd-9b23-2b6f1208dd34"}}}]}, {"uuid": "d314859a-4fed-404b-9eb0-4c1bf2504af3", "name": "load_p1rlv15606_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c32ce070-e690-4fc1-92ac-f857691de578"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e5cbc980-da5d-4976-8239-da70f4814fb8"}}}}, {"uuid": "000d3dc0-f13e-4cd1-8023-a518239f75cc", "name": "3e28fefb-5c4e-4f45-9665-959cfbf8e030_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6722127407962883, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033140171384262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "487b316a-6eae-46d8-8da4-a49b958aa033", "name": "41e083f6-fd8b-4d8c-a88c-fbf39b16359a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "000d3dc0-f13e-4cd1-8023-a518239f75cc"}}}]}, {"uuid": "99ab83ce-9bfe-4afe-9493-096f255b300d", "name": "load_p1rlv15607_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32291502-d7be-4b45-8af7-cb217448e73f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "487b316a-6eae-46d8-8da4-a49b958aa033"}}}}, {"uuid": "d0ce0434-a2e1-43af-9811-5850e3713675", "name": "0927996e-7a89-435c-8ac2-9da5f99cdc6f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6722127407962883, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033140171384262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6275d4d4-c7e3-479c-ade6-ca9995459a49", "name": "a78fce1b-9591-4a78-a53e-fef3558fa051", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d0ce0434-a2e1-43af-9811-5850e3713675"}}}]}, {"uuid": "ed46658d-25fa-4de9-93a1-c07bf5b43be0", "name": "load_p1rlv15607_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32291502-d7be-4b45-8af7-cb217448e73f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6275d4d4-c7e3-479c-ade6-ca9995459a49"}}}}, {"uuid": "37e6eb60-0fee-4f18-8a8a-691d4dd6f260", "name": "b17a6cc9-d01c-400d-b251-544ea778886f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.054093584716578, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9114545444360403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8d6d7a31-22b3-4faf-8a02-d37e283c22cb", "name": "6e65c48a-a827-4617-88b1-a1772b15461b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "37e6eb60-0fee-4f18-8a8a-691d4dd6f260"}}}]}, {"uuid": "02ec340a-8c87-4c2b-955e-5aae9a00fb2e", "name": "load_p1rlv15614_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ab2d6dc-f5bb-4320-86f3-bf08bb7cf93f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8d6d7a31-22b3-4faf-8a02-d37e283c22cb"}}}}, {"uuid": "3efb4f1c-9dca-4aa3-87db-2a1037365171", "name": "91fa5bca-4df5-4bf9-a30a-46da7bf654db_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.054093584716578, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9114545444360403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "702de970-2fb2-42de-a18b-eaa10e04da4d", "name": "339375d0-a740-4ced-85a1-ea41a96bd866", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3efb4f1c-9dca-4aa3-87db-2a1037365171"}}}]}, {"uuid": "38b862f2-5180-4529-8e6d-63b195d21ccd", "name": "load_p1rlv15614_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ab2d6dc-f5bb-4320-86f3-bf08bb7cf93f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "702de970-2fb2-42de-a18b-eaa10e04da4d"}}}}, {"uuid": "4ed6d4fa-482b-4e4c-a3af-9717ec5571f1", "name": "04a9c41e-514e-46d8-a981-f56c82f86ab6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0288569450045768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2608148575838028, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "760078dd-1eb6-403e-ae47-5fcb613d909f", "name": "90450a01-a2f4-4bdf-bddf-cf971963920d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4ed6d4fa-482b-4e4c-a3af-9717ec5571f1"}}}]}, {"uuid": "363d5f05-c5c1-45fb-8ad1-72cfdc49b352", "name": "load_p1rlv15617_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6106bbe7-7a47-4c50-8b2a-d46d7432bccf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "760078dd-1eb6-403e-ae47-5fcb613d909f"}}}}, {"uuid": "337b3c0a-48de-4e1f-abb0-f7113dfa905c", "name": "f5a3bfb4-2f3c-4665-8f9e-37812e09fe7d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0288569450045768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2608148575838028, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4af8db5e-535a-4b92-b15a-94b672e51c83", "name": "c364696d-a746-482f-a694-2077f40a5a0a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "337b3c0a-48de-4e1f-abb0-f7113dfa905c"}}}]}, {"uuid": "746f94ee-b1ee-4d67-9ea8-0137b0dd340f", "name": "load_p1rlv15617_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6106bbe7-7a47-4c50-8b2a-d46d7432bccf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4af8db5e-535a-4b92-b15a-94b672e51c83"}}}}, {"uuid": "118b10ed-dfde-40ac-bce5-9b60a224ee16", "name": "c423dd2c-9fdf-45de-a9ca-ae80ac1330ca_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3483029031483318, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6505451661884267, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c096a36-d6ee-4d43-8f51-db90300a191b", "name": "17e66d5e-3d71-4238-ad31-0c9e1bd1cea6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "118b10ed-dfde-40ac-bce5-9b60a224ee16"}}}]}, {"uuid": "9b240a29-afa4-4865-8113-dce61285e40a", "name": "load_p1rlv15622_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1151b559-3ae0-4863-9363-9b395bbfc403"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c096a36-d6ee-4d43-8f51-db90300a191b"}}}}, {"uuid": "2b7add0b-c3d1-4d2e-a2a9-20a31032ceaf", "name": "221e5460-385d-4650-90cb-ba64d3817077_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3483029031483318, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6505451661884267, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9f4c6cc9-7df8-41ef-b43b-9b6fa5d9299d", "name": "3a46e619-76b4-44c1-b1e1-10acbd222b4d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2b7add0b-c3d1-4d2e-a2a9-20a31032ceaf"}}}]}, {"uuid": "960c7b61-0dcc-4347-ad5f-706dd7dd4230", "name": "load_p1rlv15622_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1151b559-3ae0-4863-9363-9b395bbfc403"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9f4c6cc9-7df8-41ef-b43b-9b6fa5d9299d"}}}}, {"uuid": "4e34e414-770f-4d2a-8a5b-2541c00f2c38", "name": "4fda3b3e-5dfa-4b73-8a3d-f338684f3ebe_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 12.451565419664076, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.11178199687988, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e87b6646-27e9-40f3-b312-4ae56d20f783", "name": "4fda3b3e-5dfa-4b73-8a3d-f338684f3ebe_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 12.451565419664076, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.11178199687988, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "544c217e-5f15-498a-9750-46173095f189", "name": "4fda3b3e-5dfa-4b73-8a3d-f338684f3ebe_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 12.451565419664076, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.11178199687988, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5619dbe0-729d-496b-a53c-dfa9b5098b3d", "name": "6cd198bd-eba6-4100-9ef6-fd07bee7d54e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4e34e414-770f-4d2a-8a5b-2541c00f2c38"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e87b6646-27e9-40f3-b312-4ae56d20f783"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "544c217e-5f15-498a-9750-46173095f189"}}}]}, {"uuid": "81a3d98f-432e-40e7-9b4c-5838469bd7f6", "name": "load_p1rlv15628", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13eabcb1-332a-4c7a-8042-214ada721424"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5619dbe0-729d-496b-a53c-dfa9b5098b3d"}}}}, {"uuid": "0d0d1323-1ea5-4f85-b268-c6c09adbb522", "name": "8d1d965a-01d1-4b25-85ba-b67975992f72_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0240502132333855, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5295456567023789, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fc8b04d3-ff3a-4865-8fde-5b1bd3b1a8ad", "name": "9b6b6641-24b2-4219-9311-1328277c753a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0d0d1323-1ea5-4f85-b268-c6c09adbb522"}}}]}, {"uuid": "d3b8c2d1-689b-453e-91e9-7b2d36b89d4d", "name": "load_p1rlv15629_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec0bca53-a58b-4004-8dba-8defca9db4c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fc8b04d3-ff3a-4865-8fde-5b1bd3b1a8ad"}}}}, {"uuid": "8fd15230-b131-4c8c-8c58-3f1431ff2688", "name": "c3d46240-f821-4126-bc47-1abfa5d04a49_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0240502132333855, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5295456567023789, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "584328b2-9bf0-49d5-ba52-666575ee7fe6", "name": "e9380927-a696-4fef-ad69-eb89d8704985", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8fd15230-b131-4c8c-8c58-3f1431ff2688"}}}]}, {"uuid": "0ce4f795-f79d-4360-9d3d-c469cefe50ef", "name": "load_p1rlv15629_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec0bca53-a58b-4004-8dba-8defca9db4c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "584328b2-9bf0-49d5-ba52-666575ee7fe6"}}}}, {"uuid": "07faca36-6635-455b-bb11-e5d33dc5fb41", "name": "7a86b912-7590-4f5c-8842-22c89ee1209f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.459276697523187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8425022918187992, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f26f51b1-e972-4612-b052-a598f9da1ed2", "name": "ce8fc209-c9b3-4f81-8c4c-b966dc154461", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "07faca36-6635-455b-bb11-e5d33dc5fb41"}}}]}, {"uuid": "3c23a9e5-e695-4862-a1ed-1b7013922081", "name": "load_p1rlv15634_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5af6dae-d20f-4a31-9544-b9455cd639bd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f26f51b1-e972-4612-b052-a598f9da1ed2"}}}}, {"uuid": "062c5c69-88c0-4ff2-ad09-c6b4f4e6e5c7", "name": "e977cde3-24e0-48e7-952e-4cd42a95a60b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.459276697523187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8425022918187992, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "29e202bb-523d-4a00-92c4-a61cf33b8014", "name": "a8451a90-b696-43d8-9d36-15a3a6a6e378", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "062c5c69-88c0-4ff2-ad09-c6b4f4e6e5c7"}}}]}, {"uuid": "2bec8ef3-d1d1-4375-b3ad-4fcd521998da", "name": "load_p1rlv15634_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5af6dae-d20f-4a31-9544-b9455cd639bd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "29e202bb-523d-4a00-92c4-a61cf33b8014"}}}}, {"uuid": "f4c2e805-198e-4d18-93b9-2bef44ea8c3a", "name": "df77f211-3a0a-498a-89e3-b082fc8ee120_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6524083002915736, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21201745820683848, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "157134c6-e79c-411e-91d9-9ea70e645daa", "name": "57a7b7d3-f679-41f1-9db7-41157808fb4f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f4c2e805-198e-4d18-93b9-2bef44ea8c3a"}}}]}, {"uuid": "48fe9c33-79f4-47bd-9ba3-6a4d2b94dcef", "name": "load_p1rlv15638_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2715a637-d6f0-4e7b-b43e-20836bf4e614"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "157134c6-e79c-411e-91d9-9ea70e645daa"}}}}, {"uuid": "d17d3786-2de1-4665-8df1-993edcc55061", "name": "2ac54f16-2236-410d-99e9-770bb50b4cd1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6524083002915736, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21201745820683848, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "973e1374-c51c-4bbb-b95f-6b9283457b45", "name": "a7af89c0-c088-456c-baf2-7af4041c5da8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d17d3786-2de1-4665-8df1-993edcc55061"}}}]}, {"uuid": "4b180f70-5021-40fe-a7f3-6558f7c9cbd0", "name": "load_p1rlv15638_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2715a637-d6f0-4e7b-b43e-20836bf4e614"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "973e1374-c51c-4bbb-b95f-6b9283457b45"}}}}, {"uuid": "34ae07d1-4965-456f-83b7-f0911007dd8b", "name": "ee1d6b15-d1a0-4357-b0bd-3694826cf032_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1219512592986662, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8685822493081499, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "609d6800-53ba-4091-b201-c639a89f9b22", "name": "14b4f633-e879-4cc6-a1e6-73404bf779da", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "34ae07d1-4965-456f-83b7-f0911007dd8b"}}}]}, {"uuid": "8a26e622-7b55-4e5d-a0c0-c74de1ab2a4d", "name": "load_p1rlv15645_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "449098c3-4f65-4350-863f-4b7bc1f14493"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "609d6800-53ba-4091-b201-c639a89f9b22"}}}}, {"uuid": "6705cba9-52b3-44f6-be0d-5b207c79af4e", "name": "b14e774b-701d-4159-be78-c4cb209404a7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1219512592986662, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8685822493081499, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "292da20d-3df1-41dd-bedc-52931193eedc", "name": "e58612bc-30a2-4e29-b570-95ec6244c410", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6705cba9-52b3-44f6-be0d-5b207c79af4e"}}}]}, {"uuid": "b156a757-1c66-49db-9928-f98fc3643bce", "name": "load_p1rlv15645_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "449098c3-4f65-4350-863f-4b7bc1f14493"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "292da20d-3df1-41dd-bedc-52931193eedc"}}}}, {"uuid": "d3bc3cbe-2ba2-483c-9915-bcb5ce6828ef", "name": "9a5d157c-5747-4591-9475-03cad3a8c47e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.567401274738218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6497123013243786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "343e3115-3ac2-45ff-bdd7-ba9f1eeef288", "name": "137085b1-cbcb-4fee-a841-5b1852556baa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d3bc3cbe-2ba2-483c-9915-bcb5ce6828ef"}}}]}, {"uuid": "c7d94431-5e19-498e-820d-04507086783f", "name": "load_p1rlv16114_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5984e209-9f0e-4844-91e6-902c8329f13c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "343e3115-3ac2-45ff-bdd7-ba9f1eeef288"}}}}, {"uuid": "563d990f-0a48-4bd7-b6be-72ff20388a91", "name": "711144a8-1d7f-4d35-a0a6-e068c2cad6a0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.567401274738218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6497123013243786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "905c6c36-2f29-4f53-9434-9f23eac4da33", "name": "7231060f-4920-43b1-8d1f-19720e20748a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "563d990f-0a48-4bd7-b6be-72ff20388a91"}}}]}, {"uuid": "2d1287d2-7d33-4437-b0d3-ec9948e8b482", "name": "load_p1rlv16114_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5984e209-9f0e-4844-91e6-902c8329f13c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "905c6c36-2f29-4f53-9434-9f23eac4da33"}}}}, {"uuid": "4aadcbeb-c078-40bf-85e3-dc67375c909d", "name": "13cd89b5-b77c-4a31-9214-e520fd74f0ab_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7463758536661063, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1812611818115355, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "13578549-07e9-4bbe-ae2d-0e6934e18e02", "name": "44ce35c9-dc72-4262-bf60-5f311fe0d931", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4aadcbeb-c078-40bf-85e3-dc67375c909d"}}}]}, {"uuid": "271b69d3-beeb-4543-b1cf-1f1820fc4db1", "name": "load_p1rlv16115_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52d1b79d-5c6b-4b44-9998-600c6debd999"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "13578549-07e9-4bbe-ae2d-0e6934e18e02"}}}}, {"uuid": "7d7debbd-e8f9-4216-b4e4-0ae296e425e7", "name": "443a895b-503d-424b-a6d4-48b372820048_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7463758536661063, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1812611818115355, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "20226c39-1722-4a0b-8de8-c3711613ea03", "name": "f44b6716-a448-474e-b9ec-2dd11690db6e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7d7debbd-e8f9-4216-b4e4-0ae296e425e7"}}}]}, {"uuid": "96585543-3d95-45a8-bdc5-a5c1a3ec6ad6", "name": "load_p1rlv16115_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52d1b79d-5c6b-4b44-9998-600c6debd999"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "20226c39-1722-4a0b-8de8-c3711613ea03"}}}}, {"uuid": "7eaaac68-1b01-4f3f-8872-e0a5be83a3b3", "name": "d8d7bb65-b83f-4950-84a4-763f72a4230a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.915650640127065, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8660189470929796, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aefbedba-7672-4b17-9874-24e2cd6fb05a", "name": "55329a86-bb37-49ad-8576-42ccfd21db71", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7eaaac68-1b01-4f3f-8872-e0a5be83a3b3"}}}]}, {"uuid": "88bb12b4-c9e0-438a-9efc-f9ffaeb42d1d", "name": "load_p1rlv16116_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "972f8088-b67b-47d0-a86f-49179dfb1c92"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aefbedba-7672-4b17-9874-24e2cd6fb05a"}}}}, {"uuid": "04857d11-51c4-4ba0-ace8-5adbbacb71ea", "name": "b2e208d9-3790-47b8-b509-ceac371b0cbd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.915650640127065, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8660189470929796, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3098cd40-5dd6-4996-b1bc-fc3eb5f29afe", "name": "7060432c-11ff-45fc-bb69-17cfbbdfb27c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "04857d11-51c4-4ba0-ace8-5adbbacb71ea"}}}]}, {"uuid": "20214244-ec78-4484-b061-527c9dcfdbd9", "name": "load_p1rlv16116_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "972f8088-b67b-47d0-a86f-49179dfb1c92"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3098cd40-5dd6-4996-b1bc-fc3eb5f29afe"}}}}, {"uuid": "e40a3821-f79c-41ff-a11f-257beeec8693", "name": "a4c79aa9-b586-4019-a8cc-1f031e7905d7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8805170689043904, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.699573894302905, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f706d3b6-bcec-4143-947c-09637f36eb4b", "name": "4a9a3c69-4fac-494e-911d-a58c92abf5fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e40a3821-f79c-41ff-a11f-257beeec8693"}}}]}, {"uuid": "728535a5-4d13-458c-aa9a-988562645181", "name": "load_p1rlv16117_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "204899ec-81e4-4a72-bf70-69b3428a49a1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f706d3b6-bcec-4143-947c-09637f36eb4b"}}}}, {"uuid": "abced025-b8ad-43f5-b022-9c333946660d", "name": "fd6642d2-1b4c-4abb-a17c-1b3bc7447566_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8805170689043904, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.699573894302905, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "70e0dfdd-638f-4f98-ab98-9c223d03f62a", "name": "24ccfd03-28f7-438c-b20e-4534cf87b92e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "abced025-b8ad-43f5-b022-9c333946660d"}}}]}, {"uuid": "fe1c3a28-1973-4061-9d97-344b8b71c76b", "name": "load_p1rlv16117_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "204899ec-81e4-4a72-bf70-69b3428a49a1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "70e0dfdd-638f-4f98-ab98-9c223d03f62a"}}}}, {"uuid": "bac6a7f5-ae27-4fe8-a7cf-97cddabffe8c", "name": "e7fc5122-4ade-4b30-ade6-8435292aa7a3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.667455481738122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8122169683202977, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a44049d7-2b72-4a70-ae59-d4cf28f4dd96", "name": "dfd9db79-c670-4723-b1e2-f1d594819506", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bac6a7f5-ae27-4fe8-a7cf-97cddabffe8c"}}}]}, {"uuid": "a54790f2-6d25-4017-8b73-843660042c32", "name": "load_p1rlv16118_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bca0b3a0-d4cb-4a4a-9b14-aa23d9e5e5fe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a44049d7-2b72-4a70-ae59-d4cf28f4dd96"}}}}, {"uuid": "80b5eeea-9887-41a7-85cb-7fe8263902b9", "name": "1287e37f-dfea-4530-88d3-63e5043f53ba_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.667455481738122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8122169683202977, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "982851d7-722b-4f52-80d3-f957ddec7727", "name": "c6aae283-785e-4c94-99c2-c8e66c57a1c1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "80b5eeea-9887-41a7-85cb-7fe8263902b9"}}}]}, {"uuid": "ffeafe96-58a7-470c-8b86-2f5b72c44780", "name": "load_p1rlv16118_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bca0b3a0-d4cb-4a4a-9b14-aa23d9e5e5fe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "982851d7-722b-4f52-80d3-f957ddec7727"}}}}, {"uuid": "25bbbf41-6602-406b-a32c-c824e7d3bce3", "name": "0b667be0-259d-40f1-9575-2c4e63ff572c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7938373145978153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7193647721316423, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "32413a08-1791-444a-ba67-b830c75c7308", "name": "9a1dab1c-b535-4779-8363-a9f1fe9c4feb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "25bbbf41-6602-406b-a32c-c824e7d3bce3"}}}]}, {"uuid": "9dfd712f-d2cf-46ce-9818-46b2e312025e", "name": "load_p1rlv16119_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0d6e608-d5bf-40d6-9efd-f3b0922e7d77"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "32413a08-1791-444a-ba67-b830c75c7308"}}}}, {"uuid": "786605ce-febf-4166-a149-578bf4bb7da0", "name": "cd48b049-2a20-4ed6-b62c-246263e50b6e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7938373145978153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7193647721316423, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "97395db4-d9c1-4d66-aebe-354134b5507e", "name": "9b4fcdb4-3f1c-4478-8682-b5bb89d111fa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "786605ce-febf-4166-a149-578bf4bb7da0"}}}]}, {"uuid": "6c33851b-87c1-46b9-b27f-c13e571c86ce", "name": "load_p1rlv16119_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0d6e608-d5bf-40d6-9efd-f3b0922e7d77"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "97395db4-d9c1-4d66-aebe-354134b5507e"}}}}, {"uuid": "9379c229-f655-4b12-b5b2-ba95f386a272", "name": "bbd65c20-107d-4409-bdde-9ece0c47256b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3480679486659737, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1241770602848328, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "98069f9e-e37e-45ff-99c5-a57a5a77b0b6", "name": "39a00932-92f4-4396-9859-712f0cd45ddc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9379c229-f655-4b12-b5b2-ba95f386a272"}}}]}, {"uuid": "36732ab5-69dc-40c4-9af4-545e9f2c1d0e", "name": "load_p1rlv16124_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6da4b2d0-66c7-43fb-9aab-3bbac03aa989"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "98069f9e-e37e-45ff-99c5-a57a5a77b0b6"}}}}, {"uuid": "7fcc4de7-0719-40e5-9825-8270e73b0247", "name": "a89a7b08-6b09-47c6-a293-ac726779012b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3480679486659737, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1241770602848328, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a6ed8840-408f-46f0-8c09-e37395a9689c", "name": "33f4efba-208a-4673-b449-f8178987c22c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7fcc4de7-0719-40e5-9825-8270e73b0247"}}}]}, {"uuid": "4fc30b64-b173-47ad-955a-f430d7614906", "name": "load_p1rlv16124_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6da4b2d0-66c7-43fb-9aab-3bbac03aa989"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a6ed8840-408f-46f0-8c09-e37395a9689c"}}}}, {"uuid": "84b6495b-045c-4c87-964c-fb0e558e77de", "name": "4c9cc6ed-5aa4-4a20-888b-79f41b0769f6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6733980323267108, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22626974414284334, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4c058a44-e6ea-4de2-bfb9-d76d5ea629b5", "name": "774e1dff-e6e3-4619-ab4b-3303bc8b65c0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "84b6495b-045c-4c87-964c-fb0e558e77de"}}}]}, {"uuid": "d7ba0cd2-bb48-4804-a327-3721f52bfcea", "name": "load_p1rlv16126_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd41f55a-4b5d-4c19-9787-801072b3b946"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4c058a44-e6ea-4de2-bfb9-d76d5ea629b5"}}}}, {"uuid": "d2d481de-1a78-47c2-86e7-445c35b9b344", "name": "a5af0b62-a953-4f46-8b72-045b3490302b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6733980323267108, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22626974414284334, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "516af154-ecbc-4845-8119-06afe55f66f3", "name": "5ffd92d1-5896-49c7-9684-bf107e2205c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d2d481de-1a78-47c2-86e7-445c35b9b344"}}}]}, {"uuid": "8d7846f5-8730-4e0d-88f5-3e63a4dcc72d", "name": "load_p1rlv16126_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd41f55a-4b5d-4c19-9787-801072b3b946"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "516af154-ecbc-4845-8119-06afe55f66f3"}}}}, {"uuid": "5f332d82-e662-4f4d-ab2a-35c89f90831e", "name": "8905e9c5-ac07-4274-9110-4be751a1f451_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5788343693478561, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0852895205351165, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "04912ec8-5a17-4a85-84f7-0c39abc03477", "name": "746ffaf8-e596-4d3e-82fc-8d4900947fd5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5f332d82-e662-4f4d-ab2a-35c89f90831e"}}}]}, {"uuid": "0a976511-8ae9-4638-8c2c-63edd65633a5", "name": "load_p1rlv16133_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "102b9460-ea9a-4099-b16f-40b8fdf99ef7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "04912ec8-5a17-4a85-84f7-0c39abc03477"}}}}, {"uuid": "43a599a2-b62b-4612-8d2f-5884d76620fd", "name": "0d6082fc-9bea-4439-bc0d-ac1ef6436de8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5788343693478561, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0852895205351165, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9139257c-f68d-4bf2-9810-823f373b594a", "name": "342dc2c1-513f-46d8-b794-8d02a17882cd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "43a599a2-b62b-4612-8d2f-5884d76620fd"}}}]}, {"uuid": "74dd4588-7d28-4eb5-9a8d-313f8d179c7e", "name": "load_p1rlv16133_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "102b9460-ea9a-4099-b16f-40b8fdf99ef7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9139257c-f68d-4bf2-9810-823f373b594a"}}}}, {"uuid": "c0619dfd-a505-47a8-9336-79b3ec4dfb0c", "name": "0ca9810b-c5a2-430d-b6fa-554f188fa7fb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6153595559076463, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2889565281407196, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50198a08-3a43-40dc-8571-73b5bb9cd346", "name": "bfabcc6a-d17b-45ff-a2bd-afb9646f33d0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c0619dfd-a505-47a8-9336-79b3ec4dfb0c"}}}]}, {"uuid": "a2a22920-3529-4a47-9552-fee1019b5ed2", "name": "load_p1rlv16135_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "676de1a3-2dfd-4faa-a057-7739e825d136"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50198a08-3a43-40dc-8571-73b5bb9cd346"}}}}, {"uuid": "5043792a-ef7c-4496-a15d-0af4f7af8cce", "name": "9ed3f16b-eb01-4ebd-8e6a-5e66e0002290_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6153595559076463, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2889565281407196, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dcca11b3-d501-43f0-a281-3bc327b529ce", "name": "4a16d233-6640-4ea1-b6d8-ecb6386d9d6c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5043792a-ef7c-4496-a15d-0af4f7af8cce"}}}]}, {"uuid": "e470734e-dcd9-48c2-815a-0c9c72d1085d", "name": "load_p1rlv16135_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "676de1a3-2dfd-4faa-a057-7739e825d136"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dcca11b3-d501-43f0-a281-3bc327b529ce"}}}}, {"uuid": "cbc9698a-1fef-4fad-8688-d01851548ad5", "name": "7b8bc565-3431-4565-aa4f-646ed7b35c4c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0226237890173833, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.014132802344601372, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aef4db55-d145-4590-8c3a-d09b87ccc493", "name": "3cff0272-99e6-4877-af42-f17a0280d099", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cbc9698a-1fef-4fad-8688-d01851548ad5"}}}]}, {"uuid": "5829fc66-d124-4fd0-973b-6a56109a6c70", "name": "load_p1rlv16139_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c840cf3f-be15-448b-8c03-8942c586b135"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aef4db55-d145-4590-8c3a-d09b87ccc493"}}}}, {"uuid": "610f4b2f-b458-4e1a-a61a-d6632506d009", "name": "b4ba9738-c756-4d73-b5b0-0e95b8cd887d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0226237890173833, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.014132802344601372, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8d4da3d0-1148-4838-9d94-9ade8464da1e", "name": "0260069a-20b1-4411-94cc-9ffb795ebca1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "610f4b2f-b458-4e1a-a61a-d6632506d009"}}}]}, {"uuid": "91c435bb-76f2-471a-809d-13817bea407c", "name": "load_p1rlv16139_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c840cf3f-be15-448b-8c03-8942c586b135"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8d4da3d0-1148-4838-9d94-9ade8464da1e"}}}}, {"uuid": "6042efec-a7ab-418b-92e5-3ab83efbb079", "name": "56214b0e-f9e7-491d-a861-a80f43f5f299_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2601927423507288, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13915962527089715, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f6b6d87d-8daf-4cbb-9619-84739c833ecb", "name": "7a214c76-fcac-455f-b323-84b6a728afad", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6042efec-a7ab-418b-92e5-3ab83efbb079"}}}]}, {"uuid": "47b4cccd-4f53-45f0-9b6e-01951fc190d6", "name": "load_p1rlv16146_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6d21c357-1033-45e1-84a0-b82ceafe6ab8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f6b6d87d-8daf-4cbb-9619-84739c833ecb"}}}}, {"uuid": "fd23a6b8-cf91-41dc-b37f-77c1188910ba", "name": "f5874288-2c7b-457e-a546-a9300f69e414_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2601927423507288, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13915962527089715, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c729d70-656f-48bf-874f-573f7d3fad6c", "name": "d42b61b5-1b5d-4c92-8376-63d5c0d743ef", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fd23a6b8-cf91-41dc-b37f-77c1188910ba"}}}]}, {"uuid": "3b572804-1bf4-452f-8c8a-7e83f2a7df9d", "name": "load_p1rlv16146_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6d21c357-1033-45e1-84a0-b82ceafe6ab8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c729d70-656f-48bf-874f-573f7d3fad6c"}}}}, {"uuid": "944e9d08-58c5-471c-b02f-d03631e3b3fd", "name": "4cf50889-ff51-4daa-9594-f9ca031ddf2f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.954715654212962, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.874926311982217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ba4c0a9a-ea5a-47e6-9087-6ccffa088ae3", "name": "06820ee3-82e9-4d51-8bd8-82afe2e820d6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "944e9d08-58c5-471c-b02f-d03631e3b3fd"}}}]}, {"uuid": "e1d9d634-aada-4a41-9782-7b61414d440c", "name": "load_p1rlv16149_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b15792ca-a6bd-47e5-8c67-5c3076174848"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ba4c0a9a-ea5a-47e6-9087-6ccffa088ae3"}}}}, {"uuid": "d82e6c12-c88d-44bf-acac-1c129736f972", "name": "60850e0b-cb39-4f3d-8296-63d7efa32f9f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.954715654212962, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.874926311982217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d0d23c7c-b137-4edb-aa89-8cd506803c05", "name": "1f02f919-b8d7-4dcc-be93-0416be171418", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d82e6c12-c88d-44bf-acac-1c129736f972"}}}]}, {"uuid": "eee641f4-7495-49d4-b0c4-ccad20246869", "name": "load_p1rlv16149_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b15792ca-a6bd-47e5-8c67-5c3076174848"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d0d23c7c-b137-4edb-aa89-8cd506803c05"}}}}, {"uuid": "3fb5e67e-7604-49e0-84b3-242f0a723658", "name": "4f023723-4c1c-4054-982b-8b339729e62e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.199861964544811, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5137601155429989, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "babc2fd3-3af8-477f-83da-3053e5d55d9a", "name": "3a352fc0-24f9-40ff-a303-68dd6b65b760", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3fb5e67e-7604-49e0-84b3-242f0a723658"}}}]}, {"uuid": "62d2f921-6b29-450f-8efd-cc005b8fc836", "name": "load_p1rlv16156_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "74edd9e9-24a5-4b36-8ca8-24ef2fa3e972"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "babc2fd3-3af8-477f-83da-3053e5d55d9a"}}}}, {"uuid": "c638bf32-7feb-4a80-98d7-3f15f7f07683", "name": "c15e25d9-ee81-47b4-93ca-1da39af6a5ec_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.199861964544811, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5137601155429989, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "02dc8948-4499-440f-9062-51b4df1185ed", "name": "af9e2be7-aec7-47c4-9506-4e350d02b583", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c638bf32-7feb-4a80-98d7-3f15f7f07683"}}}]}, {"uuid": "ea4d056f-ebac-4652-a3bb-2f0393cf3e9b", "name": "load_p1rlv16156_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "74edd9e9-24a5-4b36-8ca8-24ef2fa3e972"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "02dc8948-4499-440f-9062-51b4df1185ed"}}}}, {"uuid": "95af027f-f060-48cf-ba7f-7a6bfe81e4d9", "name": "7444f369-9eab-404e-875f-0a874429e148_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8668291909105112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7572719732007044, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2977e7e4-a182-4eda-a621-665cdfea8b72", "name": "7723bebb-c070-4919-b2a4-43332f162739", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "95af027f-f060-48cf-ba7f-7a6bfe81e4d9"}}}]}, {"uuid": "f8017a87-cdf4-45bd-82eb-e1c5d21ff905", "name": "load_p1rlv16157_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6efff4f7-c67b-4cfb-a72d-30b6616825b1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2977e7e4-a182-4eda-a621-665cdfea8b72"}}}}, {"uuid": "0d1ea309-327f-4df9-a825-c720410aea31", "name": "2cd1e795-b6d5-4a6c-aed6-ef98f90064e8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8668291909105112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7572719732007044, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2f7cb9e1-5e4f-43bc-adab-f41910e887df", "name": "0e55a0a1-2deb-495a-9a56-f39a4c2ff82b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0d1ea309-327f-4df9-a825-c720410aea31"}}}]}, {"uuid": "289f48fe-200b-4ef8-bb85-415fb62457eb", "name": "load_p1rlv16157_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6efff4f7-c67b-4cfb-a72d-30b6616825b1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2f7cb9e1-5e4f-43bc-adab-f41910e887df"}}}}, {"uuid": "aadd63b4-0be3-4930-aa43-d0e89a049dde", "name": "340caec7-a6a9-4f57-a9f1-7c0cdd25330e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.927062407458527, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.5614641711041375, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "94718418-e166-4c74-a9f9-afa3c38c5c5e", "name": "10bccbfd-02a7-465a-ae9d-34e6334107d8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aadd63b4-0be3-4930-aa43-d0e89a049dde"}}}]}, {"uuid": "ad302c42-a4e0-4487-baea-30eb493be87c", "name": "load_p1rlv16158_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b85e180a-8eb4-4acc-a816-d99758cc16ea"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "94718418-e166-4c74-a9f9-afa3c38c5c5e"}}}}, {"uuid": "35d8cb9b-ea2b-4ad7-84b6-3ea93abe91cd", "name": "14d8755e-45f8-4f0a-ace9-26a251575b0d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.927062407458527, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.5614641711041375, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e7a4f331-391c-41c2-8708-af3c62c444b1", "name": "ad66d882-04f1-42ea-9b5d-85bf29f490a6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "35d8cb9b-ea2b-4ad7-84b6-3ea93abe91cd"}}}]}, {"uuid": "3d2b97fa-a69b-400b-8c6a-7edcc9ec5e98", "name": "load_p1rlv16158_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b85e180a-8eb4-4acc-a816-d99758cc16ea"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e7a4f331-391c-41c2-8708-af3c62c444b1"}}}}, {"uuid": "8fa57b6a-1070-49a0-ab8c-6fc7653fa1b5", "name": "d8de8e69-c8e2-40bf-ab7d-b1efcb08417f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6923563615826267, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8186846587164974, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f8c69361-b012-4381-9baf-f47e2ace3e35", "name": "7352512f-5a4e-42bf-a268-c90fbaa10bfb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8fa57b6a-1070-49a0-ab8c-6fc7653fa1b5"}}}]}, {"uuid": "ae35f4ab-be01-4151-b28c-bc457b2eaf1e", "name": "load_p1rlv16168_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fb5abb7-dd79-49aa-9185-88a90bb45bc7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f8c69361-b012-4381-9baf-f47e2ace3e35"}}}}, {"uuid": "5518dcf0-ca6d-4c31-8e14-b1fbfcbfc9a4", "name": "8f65fe76-7ec3-4c39-8ade-f8cda2b5adb4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6923563615826267, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8186846587164974, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ee0339eb-6bb9-4623-a309-40f8be220020", "name": "7b56c783-647d-4445-a892-aeeeb23f2214", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5518dcf0-ca6d-4c31-8e14-b1fbfcbfc9a4"}}}]}, {"uuid": "e1291582-16b4-44ff-8b20-af36b4546a35", "name": "load_p1rlv16168_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fb5abb7-dd79-49aa-9185-88a90bb45bc7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ee0339eb-6bb9-4623-a309-40f8be220020"}}}}, {"uuid": "759b6c81-1eff-41f0-91b3-2fa957406b90", "name": "6ceb5dc2-80f4-4575-a4de-ab9a62fd34ed_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.160237576416993, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 5.832362811342285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9e794faa-cc78-43af-92ad-d55e903534c0", "name": "79d156a2-e7af-4303-a866-c151ec2d5e3b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "759b6c81-1eff-41f0-91b3-2fa957406b90"}}}]}, {"uuid": "d37c76fa-d11a-45d6-b583-c9f1d1afe258", "name": "load_p1rlv16177_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbbe8401-53a1-4ce7-9ce1-02f547055d95"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9e794faa-cc78-43af-92ad-d55e903534c0"}}}}, {"uuid": "1ef1acd9-ea6f-4427-8451-dd0f3a5e227b", "name": "ece91088-fedf-4f6c-8fd4-020c63ffe0ae_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.160237576416993, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 5.832362811342285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "11f69efc-00f8-446d-a326-f00471de567f", "name": "ecf2035a-b5a3-40e3-8b14-7cc42e5d2d52", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1ef1acd9-ea6f-4427-8451-dd0f3a5e227b"}}}]}, {"uuid": "11b248f1-2e87-4e52-99d5-ace7c2a21dd7", "name": "load_p1rlv16177_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbbe8401-53a1-4ce7-9ce1-02f547055d95"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "11f69efc-00f8-446d-a326-f00471de567f"}}}}, {"uuid": "7db3fc2b-717d-425d-8ce2-4c368ad8a20a", "name": "31da6973-780b-499b-be21-8c61b7e98b6c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.060834559711965, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4528637167980347, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1ff20224-d53d-4d70-9fc9-a1f7ebf9208d", "name": "0ec4d3cb-1481-450d-b00b-af279a4ef278", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7db3fc2b-717d-425d-8ce2-4c368ad8a20a"}}}]}, {"uuid": "28082638-16ec-4f1c-8f35-73032dfe4ae6", "name": "load_p1rlv16178_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "807b0bef-0d34-44a9-a2a9-0c0a11f4ea8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1ff20224-d53d-4d70-9fc9-a1f7ebf9208d"}}}}, {"uuid": "811f9d5d-2c38-4000-ad90-2407c8ba381b", "name": "2ef15f6f-7918-40d9-b6ca-cc29041b0dbd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.060834559711965, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4528637167980347, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2a3acf25-d5eb-4013-b4a4-c3ae643867c7", "name": "ea4bf838-2578-43ad-adbb-7653cfafd7e0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "811f9d5d-2c38-4000-ad90-2407c8ba381b"}}}]}, {"uuid": "ecac8be1-ae8c-4ff3-a56b-ef59dff62e08", "name": "load_p1rlv16178_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "807b0bef-0d34-44a9-a2a9-0c0a11f4ea8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2a3acf25-d5eb-4013-b4a4-c3ae643867c7"}}}}, {"uuid": "cd990560-ccf7-4e47-b0a8-e54eaf37e8dd", "name": "9b055f05-34e8-4444-b73c-ac788fd443a8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8288850538480296, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31695217299610473, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b66da1a3-044a-46d1-bc15-fd8daeca6076", "name": "9d20ad51-c6df-4719-bbb3-fc460d08236b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cd990560-ccf7-4e47-b0a8-e54eaf37e8dd"}}}]}, {"uuid": "bb67aa8e-9868-4bb1-8164-10d1048423fa", "name": "load_p1rlv16197_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "92a37082-36d4-4eca-95e4-88dbcacd6db5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b66da1a3-044a-46d1-bc15-fd8daeca6076"}}}}, {"uuid": "9f6bbe6b-f152-41c4-9e9b-b4c8e195801f", "name": "24cc580e-f578-4485-b2b0-0fd8d9984bc2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8288850538480296, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31695217299610473, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2fac40fd-4c72-4eab-a08a-7602d5b740a2", "name": "77a10d6c-ca60-44f0-b5b2-ce72b05c0f2d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9f6bbe6b-f152-41c4-9e9b-b4c8e195801f"}}}]}, {"uuid": "61115f7b-14ea-43b1-98ab-6a4501c7e755", "name": "load_p1rlv16197_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "92a37082-36d4-4eca-95e4-88dbcacd6db5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2fac40fd-4c72-4eab-a08a-7602d5b740a2"}}}}, {"uuid": "51f2c6a7-abf8-40e1-b63a-5de2319c2e2e", "name": "8b4c8e30-f340-4d25-b10e-33fb7f7905c5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5775901800387742, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6237657200291109, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "597b73a2-1034-487f-99c0-2d74dc99d141", "name": "887f0fd4-281b-4a24-8373-82d40fd5bab5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "51f2c6a7-abf8-40e1-b63a-5de2319c2e2e"}}}]}, {"uuid": "fb695a11-0908-4b19-a9be-e8d1859b4c5c", "name": "load_p1rlv16200_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1aacea55-115d-46c3-9590-725cf5040f38"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "597b73a2-1034-487f-99c0-2d74dc99d141"}}}}, {"uuid": "e534beb3-a4d4-48f8-a6e7-7359ec2f1afe", "name": "a6e1477d-0917-4b47-9805-9ce404d0acf9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5775901800387742, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6237657200291109, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f8e68d22-1c77-4be7-ab6d-8b8d1a688b41", "name": "4b0eb596-282f-40d0-85d6-92ba67973883", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e534beb3-a4d4-48f8-a6e7-7359ec2f1afe"}}}]}, {"uuid": "188a1dbc-8092-4633-9710-6db102bbac68", "name": "load_p1rlv16200_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1aacea55-115d-46c3-9590-725cf5040f38"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f8e68d22-1c77-4be7-ab6d-8b8d1a688b41"}}}}, {"uuid": "d64fad99-5581-447e-a562-7368e6df2f92", "name": "925da18f-b233-4144-a409-1b24377fec95_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4950137537296666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31506625700854357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c1a632ee-3fca-43e2-a0b4-e237df300bec", "name": "e5fd1e11-75bd-45cf-8120-169d18ecd45b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d64fad99-5581-447e-a562-7368e6df2f92"}}}]}, {"uuid": "8113cfc0-7014-447a-aa9a-a78e4b9a2255", "name": "load_p1rlv16201_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68aa5cc5-f6bf-4417-8653-747c56b37b5e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c1a632ee-3fca-43e2-a0b4-e237df300bec"}}}}, {"uuid": "a0016079-70b3-4a6d-a640-8c3b1e6f6366", "name": "051018c9-0438-41c2-aad2-042ec84613e5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4950137537296666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31506625700854357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "690ba879-c2fe-4b7d-bf13-de4c8ff82366", "name": "eb8acc83-e967-44f1-97f1-480a94e04f1a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a0016079-70b3-4a6d-a640-8c3b1e6f6366"}}}]}, {"uuid": "1a299d11-654b-42f2-9549-0e1ebc5bfee8", "name": "load_p1rlv16201_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68aa5cc5-f6bf-4417-8653-747c56b37b5e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "690ba879-c2fe-4b7d-bf13-de4c8ff82366"}}}}, {"uuid": "82f80507-7e59-4d25-92e4-063d5352e131", "name": "2b930e05-b5ca-4776-b53c-2e93994c5ae3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.668048225868244, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.178282395400973, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "44a99c88-77f8-4547-a76c-e4cd0ceb5057", "name": "6a5b1ff0-2a62-4dae-b3c2-3f72552aaf24", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "82f80507-7e59-4d25-92e4-063d5352e131"}}}]}, {"uuid": "4e5070b5-da69-4033-a231-1ac0d07dd50f", "name": "load_p1rlv16206_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ca42395-8d67-4e83-80ec-159cacb490f8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "44a99c88-77f8-4547-a76c-e4cd0ceb5057"}}}}, {"uuid": "10efa989-c321-4627-b3ea-58a01ecb6c67", "name": "3087cff4-d666-4dc9-983f-07818d2217b4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.668048225868244, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.178282395400973, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6171b61a-c649-477b-b369-585b3d4f9d67", "name": "fcfee667-3a76-4915-a802-ec7625d41b65", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "10efa989-c321-4627-b3ea-58a01ecb6c67"}}}]}, {"uuid": "e6be7fda-f439-4963-ac3f-0d593ded7427", "name": "load_p1rlv16206_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ca42395-8d67-4e83-80ec-159cacb490f8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6171b61a-c649-477b-b369-585b3d4f9d67"}}}}, {"uuid": "6e3a2dd8-9d14-4656-97e1-29404e1858ed", "name": "db2f9d9c-7cc0-48af-b2fa-b337078e7f43_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8202631342288826, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.26720803692022926, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4ca4a8b8-2848-4562-84e4-b3091cabb297", "name": "a05549c7-64ca-4f21-8d1c-9ff1b5cf4180", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6e3a2dd8-9d14-4656-97e1-29404e1858ed"}}}]}, {"uuid": "38baae80-9e2b-4574-b0b8-80c9191778ea", "name": "load_p1rlv16209_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf413742-18c8-483d-b8f1-f125f95323da"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4ca4a8b8-2848-4562-84e4-b3091cabb297"}}}}, {"uuid": "0a051704-0824-4b50-9da2-9a88776bbf00", "name": "00f42130-c93c-426a-8da9-b9e3b3889a1a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8202631342288826, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.26720803692022926, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5072fd2e-6a5d-4f41-94d4-f4b07524235e", "name": "d5b24dcc-7afd-4cb1-a5ef-103b1cf30946", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0a051704-0824-4b50-9da2-9a88776bbf00"}}}]}, {"uuid": "4506020b-9977-4001-b008-07eb54d22c69", "name": "load_p1rlv16209_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf413742-18c8-483d-b8f1-f125f95323da"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5072fd2e-6a5d-4f41-94d4-f4b07524235e"}}}}, {"uuid": "f9622ad8-9c05-4623-94d2-fc3db1729d57", "name": "7ac7b347-6227-4658-8a0e-8d53c99901eb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.621947646480353, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0332384495271123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fa3d3118-0271-46bd-a8fc-ea328754fe18", "name": "cd84c6d0-7df2-4a20-845b-24648ee492c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f9622ad8-9c05-4623-94d2-fc3db1729d57"}}}]}, {"uuid": "da1537bc-3902-43ab-92af-239cf99fac5e", "name": "load_p1rlv16210_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fd05f3c-df77-45bc-8686-458b681a3d08"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fa3d3118-0271-46bd-a8fc-ea328754fe18"}}}}, {"uuid": "73b43497-48f7-4318-bc2b-74717054e651", "name": "2ef7c5ad-edd9-4aea-b435-2de079dea7a2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.621947646480353, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0332384495271123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f7675120-31a6-41cd-a416-bfe9e9b58a99", "name": "7c507e19-95e4-471d-8f33-0ca7d1770368", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "73b43497-48f7-4318-bc2b-74717054e651"}}}]}, {"uuid": "a85789d2-5bdf-40c4-8db0-32a010ac2bb9", "name": "load_p1rlv16210_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fd05f3c-df77-45bc-8686-458b681a3d08"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f7675120-31a6-41cd-a416-bfe9e9b58a99"}}}}, {"uuid": "bd71cb50-0006-42e9-ad81-75ecd8b79a48", "name": "f3080d62-ac16-4d83-8083-e140467ac72e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.08053934867757, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.19082517830123075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b64a5f67-da86-43f2-98ed-6d4f37fc6df6", "name": "9d0be648-054f-4b89-81b6-d49caf009d06", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bd71cb50-0006-42e9-ad81-75ecd8b79a48"}}}]}, {"uuid": "687d59e4-ec09-42fa-8290-945ee573225e", "name": "load_p1rlv16221_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9761003-33fa-482a-967b-b508ab67c19f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b64a5f67-da86-43f2-98ed-6d4f37fc6df6"}}}}, {"uuid": "c92936ad-112a-42cf-a795-6beca08af2e6", "name": "90c9377d-b6c7-4142-bdcc-518269e98dc2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.08053934867757, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.19082517830123075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "248dedcd-95bc-4a77-8661-b69cae451e77", "name": "27753590-42a1-496c-a0eb-79e1a17dd545", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c92936ad-112a-42cf-a795-6beca08af2e6"}}}]}, {"uuid": "25e15c21-5534-423f-b539-7fcdee678078", "name": "load_p1rlv16221_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9761003-33fa-482a-967b-b508ab67c19f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "248dedcd-95bc-4a77-8661-b69cae451e77"}}}}, {"uuid": "2e3a56f0-26d6-49c4-8278-48212669b3a8", "name": "a2b6d15a-95b2-48e7-9736-fea5cb3cf4d2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.0707881481560175, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.1283140369898392, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7d012a1d-6742-41dd-88a6-1cf39c22a3ff", "name": "86520804-049f-4fb5-8729-020319b66c13", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2e3a56f0-26d6-49c4-8278-48212669b3a8"}}}]}, {"uuid": "63aab616-7791-487d-a08b-51972220df8a", "name": "load_p1rlv16222_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4809afc1-2d3d-491d-80e5-9cd4e8da08f2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7d012a1d-6742-41dd-88a6-1cf39c22a3ff"}}}}, {"uuid": "f8befad7-db52-4f5b-bf30-4ec36de002d5", "name": "52968539-b947-42a1-b6e9-cad8ddf1b9e4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.0707881481560175, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.1283140369898392, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bf537ed1-e312-40d7-9588-585e4082e6de", "name": "eeab61f2-224c-4641-98d5-f33d205fe2bf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8befad7-db52-4f5b-bf30-4ec36de002d5"}}}]}, {"uuid": "9dc56401-aa82-4081-871e-dba02af9eb1d", "name": "load_p1rlv16222_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4809afc1-2d3d-491d-80e5-9cd4e8da08f2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bf537ed1-e312-40d7-9588-585e4082e6de"}}}}, {"uuid": "6d324efc-b032-4759-9496-6fcc6bf9f013", "name": "6730beef-de2e-4ef5-8580-c2053e941b70_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7997673490012955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.772957044307952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e7aef740-a876-4527-8c3a-81de3fb33468", "name": "e3c53125-15b6-4022-929c-1aade13ba79e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6d324efc-b032-4759-9496-6fcc6bf9f013"}}}]}, {"uuid": "1dd65483-4544-46ca-87b9-86004f8af419", "name": "load_p1rlv16228_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8767650-39c5-4d4a-80ce-af408c246599"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e7aef740-a876-4527-8c3a-81de3fb33468"}}}}, {"uuid": "08768275-2e22-4df1-8fcf-f8786fd610ab", "name": "75ed1a21-6584-4154-8564-29660d44dd60_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7997673490012955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.772957044307952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "86278f7c-6d66-40a6-9db0-49a2cb509a8a", "name": "017f4552-9fda-4e60-a865-b73ac6f60513", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "08768275-2e22-4df1-8fcf-f8786fd610ab"}}}]}, {"uuid": "23331b8c-8dbd-41bb-96e7-4a9ee02aa8ce", "name": "load_p1rlv16228_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8767650-39c5-4d4a-80ce-af408c246599"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "86278f7c-6d66-40a6-9db0-49a2cb509a8a"}}}}, {"uuid": "2384208f-c3da-4a5f-8774-5ed0b42d1775", "name": "9fb213e2-f60e-45b8-9dec-810063737f0f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.941898785419248, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8498359578625553, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d033bc93-d36e-4320-b499-6180fc5e3379", "name": "6ed32a0e-dbac-4c67-90da-a12fae14e1c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2384208f-c3da-4a5f-8774-5ed0b42d1775"}}}]}, {"uuid": "90c28d38-88fc-4f21-a316-fcf16d1a1721", "name": "load_p1rlv16235_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56b91b3f-dfdd-41bf-9d2e-a8183077c752"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d033bc93-d36e-4320-b499-6180fc5e3379"}}}}, {"uuid": "8ef99890-745e-4393-8325-fb5aa64640bc", "name": "cfc09689-4a41-4315-af0c-0f9e1c456e86_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.941898785419248, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8498359578625553, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "925e289d-82ac-4ac3-8e06-044ce8c912dc", "name": "c19e020c-bc6d-4120-b46a-4ab23c053afc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ef99890-745e-4393-8325-fb5aa64640bc"}}}]}, {"uuid": "f7a053ff-c115-476d-8880-bde065bababd", "name": "load_p1rlv16235_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56b91b3f-dfdd-41bf-9d2e-a8183077c752"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "925e289d-82ac-4ac3-8e06-044ce8c912dc"}}}}, {"uuid": "25e3363b-55dd-43a6-aa7c-52a7119bfeea", "name": "17149634-af64-479f-b5a7-cb5c71a5e4ed_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.992945339168608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.937847717707562, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "208c43d1-94a0-4344-90df-52dc7bd511d7", "name": "d6af770d-529f-4890-9352-0930b950bbb3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "25e3363b-55dd-43a6-aa7c-52a7119bfeea"}}}]}, {"uuid": "02061d0f-f540-4f78-aa26-193fbcf05a3c", "name": "load_p1rlv16239_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9642fa30-e5f7-42f1-8fda-ab75a265d25a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "208c43d1-94a0-4344-90df-52dc7bd511d7"}}}}, {"uuid": "87ba6520-cd25-4ef3-ac5b-39ccf50910aa", "name": "4e13ba8f-b575-487a-8493-6579b0d9c471_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.992945339168608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.937847717707562, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "00d96727-8577-4bde-9d0d-28049794d64a", "name": "47aeb06f-b5f7-464f-b4ff-c4d59927eb8f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "87ba6520-cd25-4ef3-ac5b-39ccf50910aa"}}}]}, {"uuid": "f591e871-f291-4273-b6bb-54f9144cd7f4", "name": "load_p1rlv16239_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9642fa30-e5f7-42f1-8fda-ab75a265d25a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "00d96727-8577-4bde-9d0d-28049794d64a"}}}}, {"uuid": "46676f65-412e-48ff-9fb8-53394bd9f99a", "name": "91b27021-aa12-45e7-aa70-f6bc9731a5b4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9337862827800336, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34425772205755256, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "415a56cf-38ae-4744-89b4-1e397956b57e", "name": "cf8aa6d7-3d6f-4c32-97a6-8b10840f41ba", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "46676f65-412e-48ff-9fb8-53394bd9f99a"}}}]}, {"uuid": "807b2c7b-8421-4be2-9991-525a59224a3a", "name": "load_p1rlv16242_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e82036d9-e6c8-42c3-b45b-30bef6902bbc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "415a56cf-38ae-4744-89b4-1e397956b57e"}}}}, {"uuid": "b8173146-9863-4a87-9624-704836c1d974", "name": "2907befd-8fc1-4310-b863-979de3223721_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9337862827800336, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34425772205755256, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cdd8a788-aa78-4ca7-9f7d-a5b151748276", "name": "fc5124bd-3d4c-4027-a48c-6b95c5adf4ee", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b8173146-9863-4a87-9624-704836c1d974"}}}]}, {"uuid": "c856e52e-6577-42dc-b16d-98eb2b4ba2d7", "name": "load_p1rlv16242_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e82036d9-e6c8-42c3-b45b-30bef6902bbc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cdd8a788-aa78-4ca7-9f7d-a5b151748276"}}}}, {"uuid": "bb93cf86-abd1-416e-9d9a-a6c9bd1ce715", "name": "ad19cd3b-2575-4a5b-b842-a965054e127a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7430249960912554, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9646854683366036, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7c4fa019-913f-42d9-8487-43baf7140118", "name": "85a9a0cd-f507-4cdf-9c94-9642caedde3c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bb93cf86-abd1-416e-9d9a-a6c9bd1ce715"}}}]}, {"uuid": "34c8cbbb-410b-4176-b515-fc86aa512951", "name": "load_p1rlv16243_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20818cc7-617e-4ab7-8f7c-31eea6496a02"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7c4fa019-913f-42d9-8487-43baf7140118"}}}}, {"uuid": "3d681fe6-c130-41b9-b824-051414bea0ef", "name": "b35ab247-2792-4051-a8cd-d1379991b7b5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7430249960912554, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9646854683366036, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c0caf009-8d97-4ccf-a18e-1c4744b66c66", "name": "7fa22bc4-e544-4985-8c30-952326b87d83", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3d681fe6-c130-41b9-b824-051414bea0ef"}}}]}, {"uuid": "067e83ef-33c4-4d7e-b6d2-b897ea32998f", "name": "load_p1rlv16243_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20818cc7-617e-4ab7-8f7c-31eea6496a02"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c0caf009-8d97-4ccf-a18e-1c4744b66c66"}}}}, {"uuid": "bbb7d194-ee30-4c7e-82bf-d6a343c5c099", "name": "c973ef57-4bea-4bf2-a02f-0b9f74f561b2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2766983969851713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5028612878254624, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0be0b900-102a-4d59-842e-2b164d4f82a4", "name": "02e72792-8785-464d-b508-fbbd4ee69536", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bbb7d194-ee30-4c7e-82bf-d6a343c5c099"}}}]}, {"uuid": "13aefa76-b966-4fcc-8857-ad70e07e674b", "name": "load_p1rlv16244_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0164339-acc1-4b95-aa31-3af42cf943f7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0be0b900-102a-4d59-842e-2b164d4f82a4"}}}}, {"uuid": "a78da743-46a7-4c08-a8e1-ceaf896565d8", "name": "ae676b84-86dd-4afa-a0a7-51a4b2fba285_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2766983969851713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5028612878254624, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a629ed77-26cc-4809-8503-c28eae2996f2", "name": "78479dde-0af5-487b-83df-a28f1a9a92fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a78da743-46a7-4c08-a8e1-ceaf896565d8"}}}]}, {"uuid": "fc7bdb18-05b5-4508-89cf-6b2d0be753ae", "name": "load_p1rlv16244_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0164339-acc1-4b95-aa31-3af42cf943f7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a629ed77-26cc-4809-8503-c28eae2996f2"}}}}, {"uuid": "49f92419-0d54-443b-8d43-33d0b1876020", "name": "26f20116-38be-47a3-a72d-30669c1a648e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.13715702476687, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3795210711832634, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6f4efc49-d644-487e-9eff-4333bb378c29", "name": "99f989f4-5b24-45b4-9f1b-0e1a29073b7f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "49f92419-0d54-443b-8d43-33d0b1876020"}}}]}, {"uuid": "79fe76ff-6ba6-465f-95d8-8a6c22d2ab39", "name": "load_p1rlv16245_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3783c838-b72e-42cd-8b0b-3005bca3cf5e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6f4efc49-d644-487e-9eff-4333bb378c29"}}}}, {"uuid": "009fce19-1ad7-46eb-a6a7-2de897f44fe7", "name": "7a433bcd-05e4-4262-b28a-b0dccca99d3e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.13715702476687, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3795210711832634, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b117b8fd-198c-4662-b556-190230cca40b", "name": "fbdb871d-ac90-4986-afb4-98f9f3c46423", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "009fce19-1ad7-46eb-a6a7-2de897f44fe7"}}}]}, {"uuid": "3a382cd8-e1bc-4c1b-9592-198db8d95239", "name": "load_p1rlv16245_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3783c838-b72e-42cd-8b0b-3005bca3cf5e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b117b8fd-198c-4662-b556-190230cca40b"}}}}, {"uuid": "c2a99cd4-f825-458d-884c-65bedb2d91ce", "name": "bb10f447-0dd9-47bb-9b43-bb2438d3ad0c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.133603663599094, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7fbeaf93-c0a2-41e2-93c1-81d2463975fc", "name": "4d94c9b3-5a90-493c-a165-f922cec9ba41", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c2a99cd4-f825-458d-884c-65bedb2d91ce"}}}]}, {"uuid": "cc498e82-9ab9-40a7-b1e3-362b034829b2", "name": "load_p1rlv16246_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd2dc2db-787a-4732-bae4-01186082a92d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7fbeaf93-c0a2-41e2-93c1-81d2463975fc"}}}}, {"uuid": "8fd4c161-fb13-4a88-ad9f-6d89a71bc353", "name": "7c4bb292-324f-44f6-ab57-7d5ef8525060_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.133603663599094, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6b2cf3bb-66d6-44aa-9f18-3339fa5074de", "name": "8e4d0312-8875-4ed0-bf5e-94b2e7461be0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8fd4c161-fb13-4a88-ad9f-6d89a71bc353"}}}]}, {"uuid": "3d44bacf-37ae-4eeb-9ec0-31965edfded3", "name": "load_p1rlv16246_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd2dc2db-787a-4732-bae4-01186082a92d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6b2cf3bb-66d6-44aa-9f18-3339fa5074de"}}}}, {"uuid": "4d5e82c2-d868-4b53-a073-007053cd037b", "name": "20d0f761-6902-4647-9a0e-5e6c1c69413f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0472938281946713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.40441110210881914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "03eef06c-dfb2-4e26-80eb-b44907416c52", "name": "7b959a9f-b5f7-4d58-aebb-ee74e4f8b29b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4d5e82c2-d868-4b53-a073-007053cd037b"}}}]}, {"uuid": "f2fe1b05-e077-42ca-8efb-c10275765edd", "name": "load_p1rlv16247_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8d5e9b7-dc95-41f9-8547-99d5e2eba874"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "03eef06c-dfb2-4e26-80eb-b44907416c52"}}}}, {"uuid": "b1b47682-7ade-48a9-9a13-7e549a05e897", "name": "11ad2d15-c8ad-4963-8a08-54201a231804_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0472938281946713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.40441110210881914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6e7104d0-2c2d-41a3-9fb8-9d72be0b0dcc", "name": "c0a8c15a-8ba9-44ac-98c5-b3d045ad36dc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b1b47682-7ade-48a9-9a13-7e549a05e897"}}}]}, {"uuid": "8111a614-f55e-4424-8ee4-434bbcae8351", "name": "load_p1rlv16247_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8d5e9b7-dc95-41f9-8547-99d5e2eba874"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6e7104d0-2c2d-41a3-9fb8-9d72be0b0dcc"}}}}, {"uuid": "9ff37076-e004-4425-a80c-3d3d8c99522d", "name": "2549db86-05ca-4352-bb29-e32892d23a92_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.398785600945231, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1157218527290627, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4613a88c-f171-4465-bc15-c79e9df82900", "name": "0c625c40-07ce-44eb-9850-e9eb6a7c6ba8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9ff37076-e004-4425-a80c-3d3d8c99522d"}}}]}, {"uuid": "9d5ffda1-a68b-4bd1-85eb-2989a2b9fb13", "name": "load_p1rlv16248_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "feb24768-feab-40f0-acc3-0b2bb500133a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4613a88c-f171-4465-bc15-c79e9df82900"}}}}, {"uuid": "0a7dc028-61ac-49b0-9e30-18f48a26ad17", "name": "807c8942-2d0d-455f-afc7-13dfc93159de_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.398785600945231, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1157218527290627, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "28bb9324-fb40-438d-a836-6880409cf4f9", "name": "fbc6768a-8fd6-4b85-a6be-605f380e2b45", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0a7dc028-61ac-49b0-9e30-18f48a26ad17"}}}]}, {"uuid": "8485dd6a-1c4a-49e3-803f-5635ffbe888b", "name": "load_p1rlv16248_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "feb24768-feab-40f0-acc3-0b2bb500133a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "28bb9324-fb40-438d-a836-6880409cf4f9"}}}}, {"uuid": "cdb85435-3309-47db-acb8-3a4839a89c95", "name": "8c0a59e0-937c-4bfb-bf0a-c0e84b341307_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c8744706-ab22-439f-abb2-6e1d0a500e5e", "name": "66c41bf8-3865-446e-a90b-1d5888d1f614", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cdb85435-3309-47db-acb8-3a4839a89c95"}}}]}, {"uuid": "ce7419eb-0876-4a0d-b3d2-2e8cc904a6ea", "name": "load_p1rlv16252_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5c6a5f39-0654-4e73-8050-c6c4ad9d54e6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c8744706-ab22-439f-abb2-6e1d0a500e5e"}}}}, {"uuid": "e477f4cc-f400-4b29-89ac-275cfab6836f", "name": "df8251ad-abb0-4b52-b0c6-32bcf56fc79f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3b142e78-a993-450e-84ba-90be31f9ed69", "name": "1312c866-677e-447c-9620-99ea07dd6e0e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e477f4cc-f400-4b29-89ac-275cfab6836f"}}}]}, {"uuid": "2350796d-9a55-42a8-9a85-fdefcd538274", "name": "load_p1rlv16252_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5c6a5f39-0654-4e73-8050-c6c4ad9d54e6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3b142e78-a993-450e-84ba-90be31f9ed69"}}}}, {"uuid": "e3b7d7a4-5f3a-41a4-b70a-5e0ec4999e4b", "name": "ee6b1bea-4ade-4e58-a2c1-0ea641f587d7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.430610855643826, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18457628630998096, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1db2a9f7-c324-4edd-9719-093ac13f48d1", "name": "0d069785-32ae-4270-b536-d1544147545c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e3b7d7a4-5f3a-41a4-b70a-5e0ec4999e4b"}}}]}, {"uuid": "33949412-5af7-4de0-9332-1bc2058e7b37", "name": "load_p1rlv16253_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "268549c6-0c8b-44ac-b933-316b36645366"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1db2a9f7-c324-4edd-9719-093ac13f48d1"}}}}, {"uuid": "53cc9afa-9837-48ce-923f-20253d4fbcf7", "name": "6f33ad52-125d-41ed-b940-d62e20895233_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.430610855643826, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18457628630998096, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9ba7469e-8d1d-4dd6-9195-589e6a163b26", "name": "e7513ceb-a589-46a9-97f8-ad86a84e318a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "53cc9afa-9837-48ce-923f-20253d4fbcf7"}}}]}, {"uuid": "74f69ee4-622b-4963-9559-731cd64ccc6a", "name": "load_p1rlv16253_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "268549c6-0c8b-44ac-b933-316b36645366"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9ba7469e-8d1d-4dd6-9195-589e6a163b26"}}}}, {"uuid": "03ab610d-cdc2-4e3e-9333-3355d230c63e", "name": "c4ca1ade-179d-432e-83aa-2c08fc697d4d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4644531671008476, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4817339405405778, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "73bc9f62-480f-46cf-afcd-8c5b94b12949", "name": "7a7f61eb-ff66-4592-b711-e8f68fb6f976", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "03ab610d-cdc2-4e3e-9333-3355d230c63e"}}}]}, {"uuid": "30737f1f-4319-4ba3-b143-efc491f42666", "name": "load_p1rlv16255_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04647fad-19dc-4ed8-8820-aa312674145c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "73bc9f62-480f-46cf-afcd-8c5b94b12949"}}}}, {"uuid": "4b23e311-7943-422d-8036-795d226c5056", "name": "4c2b9662-225b-4476-a820-ebea7dd6cd13_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4644531671008476, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4817339405405778, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9abfb742-8cbc-45c7-9c87-4371f7aaccb0", "name": "15e086d0-210c-410b-8705-47d18a32229a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4b23e311-7943-422d-8036-795d226c5056"}}}]}, {"uuid": "ed5cb148-e823-4091-ada6-468a35548c2b", "name": "load_p1rlv16255_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04647fad-19dc-4ed8-8820-aa312674145c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9abfb742-8cbc-45c7-9c87-4371f7aaccb0"}}}}, {"uuid": "b9206117-0529-4264-b73e-55b2500c05e3", "name": "ab5cd4c7-7ee7-4c21-8057-038063eaf9e2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8706127135667018, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16715860689265086, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5ea928af-bad6-4091-8dc7-75ba862f7511", "name": "bec19463-4229-4d6e-b63c-15a0450d2b4c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b9206117-0529-4264-b73e-55b2500c05e3"}}}]}, {"uuid": "7ef08658-1307-4121-8016-74f46feb38bd", "name": "load_p1rlv16256_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32a9302f-2d40-4c2a-bde9-e4039694fed7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5ea928af-bad6-4091-8dc7-75ba862f7511"}}}}, {"uuid": "4400e645-c15b-423d-a001-1fafe395d053", "name": "f9fdfbe0-2bf8-4b72-a366-e3da05e258ae_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8706127135667018, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16715860689265086, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dda8c1a5-525e-4364-af26-78e19424f467", "name": "d63cdbd6-502d-4681-99e2-a8eeb953b257", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4400e645-c15b-423d-a001-1fafe395d053"}}}]}, {"uuid": "cdeb8b48-47ad-4bf8-92c3-0363ebc6a782", "name": "load_p1rlv16256_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32a9302f-2d40-4c2a-bde9-e4039694fed7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dda8c1a5-525e-4364-af26-78e19424f467"}}}}, {"uuid": "beac4282-b4c7-4eb0-93de-2a41be630a43", "name": "925a2eb7-b2e0-46cc-b80b-bf4f2b8a93d5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5300176124233262, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6781680527999017, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d502673e-7dd3-45a6-a579-ffb9a55848f8", "name": "01ef29b7-8ff1-4800-936c-664779c361a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "beac4282-b4c7-4eb0-93de-2a41be630a43"}}}]}, {"uuid": "d28047d9-c03a-4972-8fc7-efa3a0ce86d9", "name": "load_p1rlv16257_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "935c99a6-bef6-4417-872c-0685011c440c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d502673e-7dd3-45a6-a579-ffb9a55848f8"}}}}, {"uuid": "994e5651-413a-4b97-a2b2-d5943a71cb58", "name": "828072ef-0a9d-4974-829c-5645d4bedae7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5300176124233262, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6781680527999017, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7ba5b6f2-9cab-41b0-a932-9d854bd3325b", "name": "a8b422ff-9d3e-4557-bdcd-773a89766f6f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "994e5651-413a-4b97-a2b2-d5943a71cb58"}}}]}, {"uuid": "2ba63650-a710-4e26-a30d-86e871c82e66", "name": "load_p1rlv16257_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "935c99a6-bef6-4417-872c-0685011c440c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7ba5b6f2-9cab-41b0-a932-9d854bd3325b"}}}}, {"uuid": "2f6b96cc-4721-4475-95e9-eaa8a0e85f03", "name": "63625f2b-020f-4476-9e1c-9d712ccdd87d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6722127407962883, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033140171384262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "811a9b5d-2a61-4b6c-a2e0-5ce107bc00b6", "name": "73230dbd-3733-4264-9aa6-d13e34b20755", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2f6b96cc-4721-4475-95e9-eaa8a0e85f03"}}}]}, {"uuid": "52ab00f6-292c-455d-bbba-80c1f0b5f91b", "name": "load_p1rlv16260_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdf35585-e2b3-4463-a6a8-acb352f25003"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "811a9b5d-2a61-4b6c-a2e0-5ce107bc00b6"}}}}, {"uuid": "c15b2547-d011-4db6-9d04-f1e717f0f08c", "name": "54f7a169-8b0d-47b2-8b14-27e16b6a261d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6722127407962883, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033140171384262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1af14652-b203-4f34-9074-6cdb51a10016", "name": "e9a088d2-69ef-4170-877b-8920df6b8e71", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c15b2547-d011-4db6-9d04-f1e717f0f08c"}}}]}, {"uuid": "2d908939-4308-4f5b-be72-53cc9f4d1d1e", "name": "load_p1rlv16260_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdf35585-e2b3-4463-a6a8-acb352f25003"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1af14652-b203-4f34-9074-6cdb51a10016"}}}}, {"uuid": "cc7c06ce-5557-4741-adbd-bc87cfa866a0", "name": "bb5a6a11-424e-401c-afe5-bd05c2743423_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2418080165747822, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43915934621283365, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e320a0b7-fe42-471c-8a89-4b6bdc6b5d40", "name": "362883ee-229b-4629-a632-6584f97529e5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cc7c06ce-5557-4741-adbd-bc87cfa866a0"}}}]}, {"uuid": "6842b389-cbce-4f73-840a-cc799b7336fa", "name": "load_p1rlv16261_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "978533ca-ef57-4cb6-9e7f-b3c6d1bbd7d5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e320a0b7-fe42-471c-8a89-4b6bdc6b5d40"}}}}, {"uuid": "f808bfb1-0f63-49a6-b4d7-84c408cf8403", "name": "2a7b63c6-3aa6-455e-acdc-a90973682fd4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2418080165747822, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43915934621283365, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "76000378-abb6-474c-b2ef-c9a5911ca0e0", "name": "0df3c89f-82a2-4420-9285-06a1a22b331f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f808bfb1-0f63-49a6-b4d7-84c408cf8403"}}}]}, {"uuid": "da0c47c7-3c79-431b-a175-2dcfd601d834", "name": "load_p1rlv16261_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "978533ca-ef57-4cb6-9e7f-b3c6d1bbd7d5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "76000378-abb6-474c-b2ef-c9a5911ca0e0"}}}}, {"uuid": "63fe4f3f-90de-445b-8136-d4cdd933eed8", "name": "3cffff74-ca06-4e9a-9232-7d0df38f01a8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3461402320099836, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.810674183062217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "97783810-fe85-49f2-b7b1-4af46cbb2455", "name": "3c85ce4a-02e0-4569-9661-7e6e18d6fcc6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "63fe4f3f-90de-445b-8136-d4cdd933eed8"}}}]}, {"uuid": "2478ec7b-45fe-451f-96aa-9cd41b6f9263", "name": "load_p1rlv16262_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2797febc-f5e7-4cb3-b26f-ace990dc6920"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "97783810-fe85-49f2-b7b1-4af46cbb2455"}}}}, {"uuid": "b5bd882c-07e7-4870-a1b0-72e8c0a74c42", "name": "ca1173a9-81dd-4995-b2c8-8be9f00d3b44_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3461402320099836, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.810674183062217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ad7e9c8c-0ea3-4832-aaef-b9d7c92f3ba2", "name": "0ddc8173-4d7f-46b0-91fa-215a138b9994", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5bd882c-07e7-4870-a1b0-72e8c0a74c42"}}}]}, {"uuid": "6dbd4747-2e7a-43d5-82c0-b479ca86714f", "name": "load_p1rlv16262_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2797febc-f5e7-4cb3-b26f-ace990dc6920"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ad7e9c8c-0ea3-4832-aaef-b9d7c92f3ba2"}}}}, {"uuid": "766c6dc0-d413-4dbb-a420-6b1533031cf2", "name": "7fb9e6ab-e824-4df2-a9cb-5005dcccf9b0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0052757727111112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4127143879372469, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9c4de1e6-0bd5-48b5-be95-30f7a4348c4a", "name": "a7c4d71c-995e-451f-a474-d0549dc2595b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "766c6dc0-d413-4dbb-a420-6b1533031cf2"}}}]}, {"uuid": "0219d6c8-98f6-4b98-ba29-a7464b82d3a0", "name": "load_p1rlv16266_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8835446-b333-4be9-96bd-57ff9d01ebd3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9c4de1e6-0bd5-48b5-be95-30f7a4348c4a"}}}}, {"uuid": "6dd6e2aa-1372-49e8-b910-cfe96b05329f", "name": "83b3b560-4487-470e-949c-4bba6d48ced2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0052757727111112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4127143879372469, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bfa003ca-bc4f-40f9-86c4-6a26450c4ff9", "name": "53a515c2-8ea2-459f-bea2-aca4afe2b4cc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6dd6e2aa-1372-49e8-b910-cfe96b05329f"}}}]}, {"uuid": "c786b4c3-1774-4050-8f6c-dc85c54dcd2e", "name": "load_p1rlv16266_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8835446-b333-4be9-96bd-57ff9d01ebd3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bfa003ca-bc4f-40f9-86c4-6a26450c4ff9"}}}}, {"uuid": "ac644023-aa22-402b-ace4-4f36a5673237", "name": "e670b296-ded9-440d-ab06-b3f8559514b0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.794005533851084, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6855099409421886, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "34c86588-a163-48ef-b08d-7eb6cef459c9", "name": "907ea48a-5646-4b42-92a1-dbb5541aa5db", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ac644023-aa22-402b-ace4-4f36a5673237"}}}]}, {"uuid": "499f83ff-6b0f-4a37-8418-a9a3cf315367", "name": "load_p1rlv16267_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19aeb510-ac0e-4279-8db0-8de282beccc8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "34c86588-a163-48ef-b08d-7eb6cef459c9"}}}}, {"uuid": "a80fc465-3c9d-438b-90e2-02ba863feea8", "name": "633da08d-3a5e-43ac-894b-3b2ccf0b86bf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.794005533851084, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6855099409421886, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "443427c2-6d12-4a22-b3d0-b408d981790a", "name": "17416c46-f23f-4b83-8ea4-a680905559b6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a80fc465-3c9d-438b-90e2-02ba863feea8"}}}]}, {"uuid": "127ee3f0-2b6f-46e0-953b-289dcd335a77", "name": "load_p1rlv16267_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19aeb510-ac0e-4279-8db0-8de282beccc8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "443427c2-6d12-4a22-b3d0-b408d981790a"}}}}, {"uuid": "fbe6e7b4-6025-4fac-b687-23e5575e10a1", "name": "44017a22-e3fc-440b-b8d4-7a098e0e770b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.996798907530164, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8717719006522443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a9e73675-bd7f-4896-a8ef-b46736678299", "name": "e6fc554d-c5a0-41bd-8cfc-9b4ea5d0a630", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fbe6e7b4-6025-4fac-b687-23e5575e10a1"}}}]}, {"uuid": "45761486-6e20-4090-94b4-f9d63478adc5", "name": "load_p1rlv16268_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba6ebe7f-b6b9-4f89-8bbf-7bffd63e10ef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a9e73675-bd7f-4896-a8ef-b46736678299"}}}}, {"uuid": "18caad4c-d890-448a-9ace-972ec6a6835f", "name": "5e667111-1000-4735-bc29-2f67e6a70057_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.996798907530164, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8717719006522443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dc1f1735-3f44-4f61-b875-f12cb02307da", "name": "a5de17ab-6886-4664-96b3-3b91edcb5728", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "18caad4c-d890-448a-9ace-972ec6a6835f"}}}]}, {"uuid": "ec9dbc63-2f0e-4689-9ab4-bc7d0fb48a81", "name": "load_p1rlv16268_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba6ebe7f-b6b9-4f89-8bbf-7bffd63e10ef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dc1f1735-3f44-4f61-b875-f12cb02307da"}}}}, {"uuid": "2bb55537-b3e1-4402-ae93-99f3cfc641a0", "name": "d8204634-e3fb-46cc-be88-bf688e8403ec_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.363798145332242, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4037116383567407, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "18b116f5-1ea8-404d-bac8-f2a3ef26b69b", "name": "f51befad-0132-4880-b571-049060304211", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2bb55537-b3e1-4402-ae93-99f3cfc641a0"}}}]}, {"uuid": "9bc29a80-f4ba-400b-b9d9-5db241d12b87", "name": "load_p1rlv16269_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc746539-662a-4fe4-8774-6ba2dc538118"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "18b116f5-1ea8-404d-bac8-f2a3ef26b69b"}}}}, {"uuid": "a9bcdd6a-962b-4507-947d-e42dd45d6fb1", "name": "90a80808-5225-4d5b-a3b3-22321a5f0a94_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.363798145332242, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4037116383567407, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d7b1fa47-0d96-46d5-b6cc-b9d9ecb31cec", "name": "f475d6a4-7e59-4bd1-a7d3-a45749669581", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a9bcdd6a-962b-4507-947d-e42dd45d6fb1"}}}]}, {"uuid": "4f175f3f-77a2-4b06-92d1-e3eae1b6a441", "name": "load_p1rlv16269_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc746539-662a-4fe4-8774-6ba2dc538118"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d7b1fa47-0d96-46d5-b6cc-b9d9ecb31cec"}}}}, {"uuid": "88028e8a-b39f-47f5-ae02-9827bed072f6", "name": "2a31ba10-cda3-4d2c-ad58-4118a881432a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.715296910036079, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.4546814180149177, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b8db8593-7b21-4054-b8b1-7e099912bdc2", "name": "89ed205c-4a38-46e9-afc3-163d886fe797", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "88028e8a-b39f-47f5-ae02-9827bed072f6"}}}]}, {"uuid": "858ffea9-e5e4-4ffc-9d42-b093f732e45a", "name": "load_p1rlv16270_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c620d4b9-a849-4bf6-b108-118836866602"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b8db8593-7b21-4054-b8b1-7e099912bdc2"}}}}, {"uuid": "4fb48713-2e5d-478a-8411-d43906004b3f", "name": "9fbcd029-fe06-4367-8b92-13840b382478_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.715296910036079, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.4546814180149177, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "453a6785-1ac8-404d-89d2-1428d14db38d", "name": "2ee690ab-de60-49c3-af76-f76b89005969", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4fb48713-2e5d-478a-8411-d43906004b3f"}}}]}, {"uuid": "ec15395f-4ea3-4a6d-92b1-88e1ec5f0d99", "name": "load_p1rlv16270_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c620d4b9-a849-4bf6-b108-118836866602"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "453a6785-1ac8-404d-89d2-1428d14db38d"}}}}, {"uuid": "5e911122-0db2-45dd-ac44-255e1ce2411c", "name": "03277084-12fe-4790-9668-fe8bb0eb03b1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.381399729703326, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.39528166539642545, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "32b235f2-0766-401f-8138-ad69dd2b6554", "name": "03277084-12fe-4790-9668-fe8bb0eb03b1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.381399729703326, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.39528166539642545, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fae6af08-41bc-4ece-913d-30dbceb3662d", "name": "03277084-12fe-4790-9668-fe8bb0eb03b1_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.381399729703326, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.39528166539642545, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "653f0d5d-08e0-47e1-a06d-715772f43c9d", "name": "8d7aafb3-8c0d-44f7-a78c-8cd67e83374a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5e911122-0db2-45dd-ac44-255e1ce2411c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "32b235f2-0766-401f-8138-ad69dd2b6554"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fae6af08-41bc-4ece-913d-30dbceb3662d"}}}]}, {"uuid": "d43dadee-e804-47c5-b631-82815e8ff5a5", "name": "load_p1rlv16271", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "606bf8f6-d745-4220-8cae-e01ffd22f669"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "653f0d5d-08e0-47e1-a06d-715772f43c9d"}}}}, {"uuid": "8ff3666a-1963-476c-b693-6e282e2a9e80", "name": "e2a47060-377d-427a-a38f-820686e5aa38_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.200687176070838, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9185981858680964, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f9123dcb-c7b3-422d-a8ea-8221e79caf63", "name": "0220b4c2-aa64-438f-ab3b-53e41f2f2d09", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ff3666a-1963-476c-b693-6e282e2a9e80"}}}]}, {"uuid": "031b5c59-2c52-4aec-8004-569f6c5a58d6", "name": "load_p1rlv16395_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d908890-4fe4-4349-92de-464c4165b185"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f9123dcb-c7b3-422d-a8ea-8221e79caf63"}}}}, {"uuid": "94238b3a-7fbf-4103-85a7-29eed43f218a", "name": "4e22a016-eb19-423a-bd1a-f2163e3af209_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.200687176070838, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9185981858680964, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "df08e771-7168-481a-ac9d-db1982a6beba", "name": "59f2bd06-7d04-442c-8ebd-4482658d2f47", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "94238b3a-7fbf-4103-85a7-29eed43f218a"}}}]}, {"uuid": "e193f5cd-04c5-410c-9bc1-24636b2ade55", "name": "load_p1rlv16395_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d908890-4fe4-4349-92de-464c4165b185"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "df08e771-7168-481a-ac9d-db1982a6beba"}}}}, {"uuid": "5e8f9a6c-45eb-41d2-a216-cdb7483ef44f", "name": "1566d76b-0145-466e-82c6-a75d0c430211_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.2106819008595595, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9283160881681002, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8c99023a-c460-4f29-b354-305ff8386f11", "name": "34e343f9-2dce-4c6f-9eea-d1134fa429fc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5e8f9a6c-45eb-41d2-a216-cdb7483ef44f"}}}]}, {"uuid": "78ba092a-6d63-42c4-9de8-782f0fe22265", "name": "load_p1rlv16397_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "323373a9-8e7d-4fb4-8970-dcc0e6d26c98"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8c99023a-c460-4f29-b354-305ff8386f11"}}}}, {"uuid": "63422d23-642b-4d3b-81af-4314d3fcd30a", "name": "7078de00-ecb8-4875-9964-76435221690b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.2106819008595595, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9283160881681002, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bb56652e-af5e-41f7-a9ee-946da3e3082c", "name": "98160b95-d28a-4371-a8da-a13f3b99df61", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "63422d23-642b-4d3b-81af-4314d3fcd30a"}}}]}, {"uuid": "fa96bddd-c21e-4501-99b6-78db3a2ca659", "name": "load_p1rlv16397_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "323373a9-8e7d-4fb4-8970-dcc0e6d26c98"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bb56652e-af5e-41f7-a9ee-946da3e3082c"}}}}, {"uuid": "e0b8d152-b240-434a-abe9-c4a70a2db003", "name": "38583533-e4ea-4249-8e7e-1c4ed998db82_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.920542613760824, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4990926315178331, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9e3961fc-f9f8-4891-951a-23e65d454092", "name": "a0ae2021-193a-4953-980f-f36acf97e0fd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e0b8d152-b240-434a-abe9-c4a70a2db003"}}}]}, {"uuid": "e4861e25-be6b-4ee7-8e99-6ede3986573d", "name": "load_p1rlv16401_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eeb598c2-f0b9-44df-bfaa-be66e4dc3920"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9e3961fc-f9f8-4891-951a-23e65d454092"}}}}, {"uuid": "3eb79a2e-5060-4dbc-9c72-5a4579c04793", "name": "5c536cf4-fa72-451d-be0d-a0e6fd1991be_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.920542613760824, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4990926315178331, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "895c87e5-e252-4913-a419-0644656b383d", "name": "62f3429e-8711-4c19-a7bb-3ce027f757a4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3eb79a2e-5060-4dbc-9c72-5a4579c04793"}}}]}, {"uuid": "a4fc401f-e024-44ee-bdbf-fce51a70f474", "name": "load_p1rlv16401_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eeb598c2-f0b9-44df-bfaa-be66e4dc3920"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "895c87e5-e252-4913-a419-0644656b383d"}}}}, {"uuid": "0cb39cce-8587-42be-8a63-ae3f59f5498a", "name": "eaf5cd82-120d-4055-93ae-a5c5fadd5609_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.747873943758341, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9398519580990949, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a7d066f-f450-4423-a697-67bfabe799b6", "name": "2e5625b0-4790-436b-8bf6-f13c9400d604", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0cb39cce-8587-42be-8a63-ae3f59f5498a"}}}]}, {"uuid": "972c7a59-6ae7-404e-81c7-fa45c57dfe21", "name": "load_p1rlv16412_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99f97a6b-4e94-4a35-ad00-12e7004ab5e3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0a7d066f-f450-4423-a697-67bfabe799b6"}}}}, {"uuid": "a8d982e1-2a2e-460e-883b-a181406ff941", "name": "9c75b838-e827-4110-a6bf-ef41c34de906_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.747873943758341, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9398519580990949, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dbaadde4-0d3c-44c0-b295-8e7e110e0148", "name": "1305a3ed-9851-45cb-8f23-09fdbd0d484b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a8d982e1-2a2e-460e-883b-a181406ff941"}}}]}, {"uuid": "71897fc9-f974-473a-8e44-b653f2d4c7c9", "name": "load_p1rlv16412_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99f97a6b-4e94-4a35-ad00-12e7004ab5e3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dbaadde4-0d3c-44c0-b295-8e7e110e0148"}}}}, {"uuid": "fb4a62a0-6b8b-4aa4-a292-412cd593e270", "name": "bd94fb3e-a911-4262-9c76-ea0664b61703_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9024769844937937, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4778358547008617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fd827a6d-018c-4b7a-bb2a-6ed130bd6e6e", "name": "59cdad1d-5b1e-4c9b-bfc1-512f9c41b5a2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fb4a62a0-6b8b-4aa4-a292-412cd593e270"}}}]}, {"uuid": "2ce8b856-2d26-4281-aaab-596c3aa921b1", "name": "load_p1rlv16416_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f58421d6-268b-417f-a579-c9c51d010697"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fd827a6d-018c-4b7a-bb2a-6ed130bd6e6e"}}}}, {"uuid": "39d86888-aaa7-4a94-b9ec-9444c822057c", "name": "c8dbd97e-f5f6-4daa-a313-2c40117c05c7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9024769844937937, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4778358547008617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "847117f1-9f81-41be-b42e-fd15caeb15e1", "name": "ef194679-6d04-4f0d-9bd6-d5cb958e0160", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "39d86888-aaa7-4a94-b9ec-9444c822057c"}}}]}, {"uuid": "144a5cf3-f2a4-499f-8c1d-a996c5975237", "name": "load_p1rlv16416_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f58421d6-268b-417f-a579-c9c51d010697"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "847117f1-9f81-41be-b42e-fd15caeb15e1"}}}}, {"uuid": "b5b3d6cf-cf26-41b1-92fa-2c00a700f522", "name": "e3c3d445-ec7d-4307-a035-29b44e2cffc9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.100297733607771, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.379845362785626, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "48234896-3c26-4383-bf9c-7bb1d6ccc698", "name": "d661ec93-2b74-4ca4-acae-c25a38675b40", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5b3d6cf-cf26-41b1-92fa-2c00a700f522"}}}]}, {"uuid": "50b75eea-371d-414e-84a7-a37d6213dc2f", "name": "load_p1rlv16422_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f367b63c-c4cb-4810-a270-8bd0153b7b32"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "48234896-3c26-4383-bf9c-7bb1d6ccc698"}}}}, {"uuid": "f76aa752-5d3c-4be3-8a2d-1fabc5243c2c", "name": "674f99af-8538-4b59-ab83-3a7769bc1e72_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.100297733607771, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.379845362785626, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7cfa42c3-e840-422f-80a5-74b8ec5dde7b", "name": "da5a56e2-0034-4629-8766-d31f5dbcf160", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f76aa752-5d3c-4be3-8a2d-1fabc5243c2c"}}}]}, {"uuid": "84ee1d2a-1808-4c42-b6ba-45fe48465d3e", "name": "load_p1rlv16422_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f367b63c-c4cb-4810-a270-8bd0153b7b32"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7cfa42c3-e840-422f-80a5-74b8ec5dde7b"}}}}, {"uuid": "acb00d95-db2f-40e8-beb1-a4e8a45da78d", "name": "b4cdad6e-5ab2-4a57-ab7e-e4f723888a64_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7146312183983485, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.11264482158049681, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "be571320-8f57-4664-9bb6-d56b2d52f5a2", "name": "13c3ce49-f12c-4cf8-bdad-35c19c524a2a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "acb00d95-db2f-40e8-beb1-a4e8a45da78d"}}}]}, {"uuid": "545bdbcc-1bb9-4d47-88c5-63387a19ba86", "name": "load_p1rlv16424_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2242f1c-542f-4c1f-b3e6-19482cccde8d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "be571320-8f57-4664-9bb6-d56b2d52f5a2"}}}}, {"uuid": "ddbcc4d0-063e-42c3-aed6-33dbcc9717b4", "name": "6301a0e2-3050-41f1-82f2-e9b469ea8890_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7146312183983485, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.11264482158049681, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "de5e16e3-2362-49da-8da5-dd4fab6e1d8f", "name": "a907226d-90ca-4a98-b898-33882224f3d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ddbcc4d0-063e-42c3-aed6-33dbcc9717b4"}}}]}, {"uuid": "ca76d76a-35c5-4ce5-bb21-a6c2111d97f8", "name": "load_p1rlv16424_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2242f1c-542f-4c1f-b3e6-19482cccde8d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "de5e16e3-2362-49da-8da5-dd4fab6e1d8f"}}}}, {"uuid": "0957b252-5e47-41f7-b6a2-e6577b17d3ce", "name": "bc925ba2-7d8a-4708-b132-5ece3fa00e87_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.793928923123666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.7667648924934154, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "60d2dcc2-e172-4041-abfb-5298882919e7", "name": "5d0b074a-5d1c-4241-a268-95c5b2571918", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0957b252-5e47-41f7-b6a2-e6577b17d3ce"}}}]}, {"uuid": "ed7f906d-4b9f-4f83-8d0a-58f61acbdb93", "name": "load_p1rlv16445_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e090544-3c8e-4716-9dae-0b311a1017ea"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "60d2dcc2-e172-4041-abfb-5298882919e7"}}}}, {"uuid": "883d160b-99e7-4ffd-8b68-43ee7cb47fea", "name": "4426ee03-4e04-42bf-93e1-5f2e1c49824f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.793928923123666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.7667648924934154, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "55dfe357-873c-47e5-ab06-37d5c04becd5", "name": "921d10ba-5e6b-49f7-b86e-1cd9aa75fb05", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "883d160b-99e7-4ffd-8b68-43ee7cb47fea"}}}]}, {"uuid": "1e183d4f-b8fd-497d-a0ad-f733ce506ce7", "name": "load_p1rlv16445_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e090544-3c8e-4716-9dae-0b311a1017ea"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "55dfe357-873c-47e5-ab06-37d5c04becd5"}}}}, {"uuid": "5a211146-e012-456c-acc9-8cc008eca9a0", "name": "3e340988-092c-4bf0-884c-e6848c72bdba_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5124251878637117, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2529156883724651, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "23ee6240-dfad-4b00-9260-13fe18d5afeb", "name": "c47a35b0-fcfc-44d7-ad74-1fce01a4fee3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5a211146-e012-456c-acc9-8cc008eca9a0"}}}]}, {"uuid": "f8f20623-08e0-49eb-8fd4-80a55e1449e2", "name": "load_p1rlv16570_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53d578d8-8492-471b-8f66-233e489a3652"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "23ee6240-dfad-4b00-9260-13fe18d5afeb"}}}}, {"uuid": "e6193a80-06aa-4c97-bb3a-f13e1fa7f569", "name": "2e814c98-0b7a-40b2-bfd4-cfbb60c0e567_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5124251878637117, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2529156883724651, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d87b565f-a5cf-4cb5-ac56-00d16fe1fba6", "name": "806e10c4-878d-48c1-b69f-077aed7b90ab", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e6193a80-06aa-4c97-bb3a-f13e1fa7f569"}}}]}, {"uuid": "8c31522e-cd10-4472-9fa2-5b897e757d1c", "name": "load_p1rlv16570_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53d578d8-8492-471b-8f66-233e489a3652"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d87b565f-a5cf-4cb5-ac56-00d16fe1fba6"}}}}, {"uuid": "4306f62f-dad2-4a33-bc8d-b31aaa97026e", "name": "1ab8d14c-2283-4cd0-ba17-80293c683a51_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9337862827800336, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34425772205755256, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cb6a0dc7-444c-4267-956a-8b9390366a6c", "name": "ad737204-4fee-40ca-a2c2-99bd4fb6f4d0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4306f62f-dad2-4a33-bc8d-b31aaa97026e"}}}]}, {"uuid": "13635ed1-a73b-4dc9-994c-9462be78e2f2", "name": "load_p1rlv16882_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4faf40b9-9ade-45b5-ade8-3f1833605cd1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cb6a0dc7-444c-4267-956a-8b9390366a6c"}}}}, {"uuid": "5bcd5511-2529-4eb7-8457-f438d0ac891c", "name": "11edd1eb-b4c5-453c-88e0-6f85e656d400_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9337862827800336, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34425772205755256, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bedbef98-fe52-4764-884c-77bb39d1915b", "name": "2d845e5b-b7bc-441a-80ac-faf2ef20b6fa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5bcd5511-2529-4eb7-8457-f438d0ac891c"}}}]}, {"uuid": "fe9e25b6-5829-4ee2-95d3-fc3be395fe81", "name": "load_p1rlv16882_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4faf40b9-9ade-45b5-ade8-3f1833605cd1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bedbef98-fe52-4764-884c-77bb39d1915b"}}}}, {"uuid": "67097ee4-b9be-4d31-9082-f7cf66ee0049", "name": "7e3c2e38-0f54-4726-8760-d92e4426f3d5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7142625617629952, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4166771141877461, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "14d97bf2-c194-4d47-a769-752dcc747f0f", "name": "5a6eaf75-f71b-43c8-ac57-516d27edcc59", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "67097ee4-b9be-4d31-9082-f7cf66ee0049"}}}]}, {"uuid": "8b5cf97f-791d-48cb-ad48-c2d8996a3bb1", "name": "load_p1rlv16904_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c570ef7-c483-4c1e-b0fd-8712e8e9a7cd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "14d97bf2-c194-4d47-a769-752dcc747f0f"}}}}, {"uuid": "e4e83eb7-f622-4640-af52-46e1d50e9da0", "name": "9a014efa-0f29-42bb-aca3-cb1ecfc50a01_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7142625617629952, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4166771141877461, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8af8e30a-1df0-4b5e-a815-a5afb6dbceb1", "name": "4e8548d9-9864-4a11-ae5f-66f3b465cc8b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e4e83eb7-f622-4640-af52-46e1d50e9da0"}}}]}, {"uuid": "857cf48e-9845-4a5a-bf80-2ceb844a67c1", "name": "load_p1rlv16904_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c570ef7-c483-4c1e-b0fd-8712e8e9a7cd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8af8e30a-1df0-4b5e-a815-a5afb6dbceb1"}}}}, {"uuid": "df222f2e-23dd-468f-abac-32289594b03b", "name": "f655d0ce-0bc4-45c4-bb49-ab4042a2ba9e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9815403167210675, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24442739866112323, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bc3ab1a5-9b77-46b0-9f7c-253a91bd57d3", "name": "bae5a9cd-a7ea-4ee4-9283-9944acb0cd4d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "df222f2e-23dd-468f-abac-32289594b03b"}}}]}, {"uuid": "d4a1993f-3687-4bac-b090-3ff6435c1d4e", "name": "load_p1rlv16905_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7578563f-d4b3-423b-a8f5-3ee91a042d19"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bc3ab1a5-9b77-46b0-9f7c-253a91bd57d3"}}}}, {"uuid": "fa94f8b3-d59f-46a5-a6bb-e9b83759f5cc", "name": "b3c28b6d-786a-4772-9800-eea955d5fc28_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9815403167210675, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24442739866112323, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "694a5d1c-d56c-47f4-b69f-6da3db4ec8cb", "name": "8f57c6a1-5078-4d04-9e2a-232279038f1a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fa94f8b3-d59f-46a5-a6bb-e9b83759f5cc"}}}]}, {"uuid": "a91940b7-1c3f-47c8-93b0-e337ac5fb2d4", "name": "load_p1rlv16905_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7578563f-d4b3-423b-a8f5-3ee91a042d19"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "694a5d1c-d56c-47f4-b69f-6da3db4ec8cb"}}}}, {"uuid": "866ee746-a9bb-4d9c-ac8d-b42925c2c936", "name": "16d64a28-9219-4b9e-8f02-0912ba526235_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1343287185333217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10429894918818222, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d281b117-2cfb-4d45-8fed-08e1d7ffcf94", "name": "a81c35a6-347a-4126-a0e4-f8d300079da2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "866ee746-a9bb-4d9c-ac8d-b42925c2c936"}}}]}, {"uuid": "ad5a7f1b-50a3-44c6-9f2c-ea3d4ba82a5c", "name": "load_p1rlv16912_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2308dc3-d10b-4049-862d-caf3356fa9a7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d281b117-2cfb-4d45-8fed-08e1d7ffcf94"}}}}, {"uuid": "44ebafdb-92a3-4071-b231-b704f0339e29", "name": "3a39d6e5-1381-45d2-a9fc-0ad7b0f1f80f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1343287185333217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10429894918818222, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "185703fc-cf0d-4f5b-b80f-56147a287127", "name": "952ebf46-a3d9-4ca9-b4e1-f01b4ce8a248", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "44ebafdb-92a3-4071-b231-b704f0339e29"}}}]}, {"uuid": "fd6e366d-3ed9-4ed3-ad86-5d5dab393117", "name": "load_p1rlv16912_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2308dc3-d10b-4049-862d-caf3356fa9a7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "185703fc-cf0d-4f5b-b80f-56147a287127"}}}}, {"uuid": "73edb9fc-934c-47f0-9015-56196051abfa", "name": "b74a2985-70da-447e-8ac4-c0bd47dea132_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2143639459232007, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7122713279236396, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4710cb21-5f36-4516-ac1e-c0d9f0c0ef39", "name": "53f178ef-52ba-47fa-b976-d30d5d10ccbe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "73edb9fc-934c-47f0-9015-56196051abfa"}}}]}, {"uuid": "43230887-62aa-439a-85e3-abc02603d949", "name": "load_p1rlv16919_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07e01053-37f3-4b9f-a9f1-d51bccd29803"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4710cb21-5f36-4516-ac1e-c0d9f0c0ef39"}}}}, {"uuid": "86d6c8a3-2319-4a32-a922-c9ac44d610dd", "name": "318b9101-6f0f-4353-b5c1-8a27537eef2b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2143639459232007, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7122713279236396, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "919cfc31-0be3-4208-bf84-58b3309fc292", "name": "1b4463c8-f9b7-4cfb-90a3-709b2892605d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "86d6c8a3-2319-4a32-a922-c9ac44d610dd"}}}]}, {"uuid": "a3d23238-a2d4-4e9e-8634-ebbb3d8e4a49", "name": "load_p1rlv16919_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07e01053-37f3-4b9f-a9f1-d51bccd29803"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "919cfc31-0be3-4208-bf84-58b3309fc292"}}}}, {"uuid": "90d19537-202e-4e99-9cdf-927be743f348", "name": "7f3a53b7-4837-4378-a8e1-fc886f275bc3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.639612501586281, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0977377571892493, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ae8b7549-b9c4-42b7-b6aa-eecd7bb1aa64", "name": "c645099e-0bfa-4f86-a6b3-d9b7c7a32c74", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "90d19537-202e-4e99-9cdf-927be743f348"}}}]}, {"uuid": "357d6e7d-d014-4950-8144-fd7502b9f6de", "name": "load_p1rlv16922_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce315d98-1556-429b-aebb-0c868892396a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ae8b7549-b9c4-42b7-b6aa-eecd7bb1aa64"}}}}, {"uuid": "f035a725-f539-40d0-b933-6da8edcb77d5", "name": "d0cf8fdd-fa68-49a4-8977-cf240c7ad71d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.639612501586281, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0977377571892493, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e643043d-ffbf-476a-ac58-ece88d41d61b", "name": "b31151a5-91b8-4e1d-93b7-31bbd6026038", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f035a725-f539-40d0-b933-6da8edcb77d5"}}}]}, {"uuid": "b40d9973-ff90-40bc-81dc-47776eb3ec4d", "name": "load_p1rlv16922_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce315d98-1556-429b-aebb-0c868892396a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e643043d-ffbf-476a-ac58-ece88d41d61b"}}}}, {"uuid": "269e746a-750e-4682-a328-d6112a6b4c81", "name": "a1e2c112-06a4-43cd-8c40-d406276e9962_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8791002615066037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24190904367644575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d77d41b1-5754-48bd-a7e9-50f52f40292b", "name": "94f922d3-6550-4f04-a21f-e2607de92a1a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "269e746a-750e-4682-a328-d6112a6b4c81"}}}]}, {"uuid": "3bf281d4-9ac9-4acf-9a5b-40552c83d5aa", "name": "load_p1rlv16926_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ba1d053-4462-4eb4-aca6-5ede38aa283c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d77d41b1-5754-48bd-a7e9-50f52f40292b"}}}}, {"uuid": "c1f34f7a-2f15-42c3-b742-defc4351a6d7", "name": "e8c1986b-032b-42ac-970b-c9e7d2f39d4f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8791002615066037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24190904367644575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8e73e7fb-0082-427b-bd92-3eab59da11f8", "name": "3b75e35b-133f-42a5-959b-c9303ca23409", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c1f34f7a-2f15-42c3-b742-defc4351a6d7"}}}]}, {"uuid": "c6019ae8-df4a-41f0-97a2-855d85873f24", "name": "load_p1rlv16926_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ba1d053-4462-4eb4-aca6-5ede38aa283c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8e73e7fb-0082-427b-bd92-3eab59da11f8"}}}}, {"uuid": "e4798d07-13c7-4501-b729-ce5eda382096", "name": "78e0bede-b943-41f4-bae9-36cc1b941ed1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.618088489787842, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20923793518521916, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c1a46fd4-dc1f-4a50-921e-34cb0e661c0a", "name": "a477015b-a6b4-4d59-8118-6409d2d5163a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e4798d07-13c7-4501-b729-ce5eda382096"}}}]}, {"uuid": "d25e070f-7ee8-4373-901d-635190d93b31", "name": "load_p1rlv16957_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7dff1455-5154-429f-a33f-044d8501281d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c1a46fd4-dc1f-4a50-921e-34cb0e661c0a"}}}}, {"uuid": "f4578af1-d2ff-4d34-aeb0-e1f28782f43a", "name": "a8087e06-51a4-4993-be20-3a0a57beb633_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.618088489787842, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20923793518521916, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9318be11-995a-4a84-8c1b-fdec953d1314", "name": "bc987390-8d02-46bb-96c3-abc5e3303f43", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f4578af1-d2ff-4d34-aeb0-e1f28782f43a"}}}]}, {"uuid": "b2bfe792-092e-441f-9a3f-1dc753a5797c", "name": "load_p1rlv16957_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7dff1455-5154-429f-a33f-044d8501281d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9318be11-995a-4a84-8c1b-fdec953d1314"}}}}, {"uuid": "820bf4c1-a84c-44fc-bc19-11ed37eede7a", "name": "b21a5757-7bac-4856-9a9c-fc91a7957da8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.625738069985529, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4783299291729874, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ae2df8a9-90b4-4937-8ba7-7d29299cf81a", "name": "1bbaf78b-e251-4fb1-b435-eeb6c539182c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "820bf4c1-a84c-44fc-bc19-11ed37eede7a"}}}]}, {"uuid": "c8dc1e85-f14e-49ac-8c5b-575e8bd62139", "name": "load_p1rlv16988_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11a633b0-2b09-4c66-94d4-d1c24cdd9cf5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ae2df8a9-90b4-4937-8ba7-7d29299cf81a"}}}}, {"uuid": "4fa90c01-ad5c-46ea-9b67-f1f85fb22042", "name": "63dc0f2c-4e69-4774-ae09-76780325d50b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.625738069985529, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4783299291729874, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ce4e0397-bcde-4b5f-8f7d-ce18e8885f2f", "name": "97149d3e-e2d8-419c-be96-c1abb64771c0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4fa90c01-ad5c-46ea-9b67-f1f85fb22042"}}}]}, {"uuid": "7a3dccae-2afa-4b23-b00a-910ae9ee1e94", "name": "load_p1rlv16988_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11a633b0-2b09-4c66-94d4-d1c24cdd9cf5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ce4e0397-bcde-4b5f-8f7d-ce18e8885f2f"}}}}, {"uuid": "4e5f4c5a-680a-4f82-9034-36b07c8af7df", "name": "b885c838-d5dd-401e-ab5b-f72e6a9b3074_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.857442654178314, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2722739314206026, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "70e96277-938a-41c9-872a-8953540c78f5", "name": "ea7d936e-d128-4341-a104-320475c1e68b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4e5f4c5a-680a-4f82-9034-36b07c8af7df"}}}]}, {"uuid": "0779aa7d-23e6-469b-bb88-25f2c5129f2f", "name": "load_p1rlv16992_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57e8aa34-3967-4f22-a978-cb513c49c153"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "70e96277-938a-41c9-872a-8953540c78f5"}}}}, {"uuid": "06636b1d-a342-42c8-8bd7-c49a0ab471d8", "name": "166da0d3-69b9-4e6c-90d7-1000d285d483_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.857442654178314, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2722739314206026, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "518e716f-a60e-4234-b173-d798f3671506", "name": "ab9fd947-c1b8-4877-a6eb-1c2f4401f41f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "06636b1d-a342-42c8-8bd7-c49a0ab471d8"}}}]}, {"uuid": "5bc1200b-19a4-4abd-ba8a-00031764829e", "name": "load_p1rlv16992_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57e8aa34-3967-4f22-a978-cb513c49c153"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "518e716f-a60e-4234-b173-d798f3671506"}}}}, {"uuid": "611fc267-7aa7-4bd8-8a31-aa63454e8e6c", "name": "fc502c9f-1d0c-4059-8f4c-88cd04fc680a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.5934418714018275, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3543697694181257, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "226fb417-254c-4e53-a5be-e88fa31856ff", "name": "0f9c2336-ba2c-4fe5-a661-2f9548ed1a65", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "611fc267-7aa7-4bd8-8a31-aa63454e8e6c"}}}]}, {"uuid": "7d3dd409-551e-4f07-a551-c0f615947d75", "name": "load_p1rlv17001_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f23214ee-3032-4403-9084-8117e89cb1cf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "226fb417-254c-4e53-a5be-e88fa31856ff"}}}}, {"uuid": "5c9d54af-9d15-445e-a04b-4b145ad9f1d8", "name": "5b9f9520-e11b-4645-b326-179d276830e7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.5934418714018275, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3543697694181257, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "30f29dcc-36bf-448b-8a1a-d8548da4f9ad", "name": "28b1e0c3-9834-405c-a87f-2705fc391994", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5c9d54af-9d15-445e-a04b-4b145ad9f1d8"}}}]}, {"uuid": "0310305e-5c68-4087-9f9c-31846d771f30", "name": "load_p1rlv17001_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f23214ee-3032-4403-9084-8117e89cb1cf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "30f29dcc-36bf-448b-8a1a-d8548da4f9ad"}}}}, {"uuid": "df4178c3-55ce-4da9-9e72-0d46e025bcfb", "name": "f7ccd451-931b-4ad7-86d7-540ffdf4d7f1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4585094523583652, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.19519922093662737, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "05dbd0b9-81d8-43a3-8b26-a8d014421a8e", "name": "e289882a-20f6-4105-93ed-2b41595bc8e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "df4178c3-55ce-4da9-9e72-0d46e025bcfb"}}}]}, {"uuid": "c7872ad2-77a0-4783-a58a-0014484bc2fd", "name": "load_p1rlv17028_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "213e6d98-ad57-4034-b2d0-4b096554cac2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "05dbd0b9-81d8-43a3-8b26-a8d014421a8e"}}}}, {"uuid": "9691ae32-fcce-4a5d-b7f9-2e0fd069df12", "name": "990c2f2a-51fa-4f7e-9be8-63cd80dfc8eb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4585094523583652, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.19519922093662737, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f5dbb8ee-a3ac-45d5-8565-cb868d8dcacc", "name": "2e596eab-4423-44c3-bfcd-fe7eab956605", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9691ae32-fcce-4a5d-b7f9-2e0fd069df12"}}}]}, {"uuid": "5118ee7c-01df-439c-8062-4621c59ad19d", "name": "load_p1rlv17028_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "213e6d98-ad57-4034-b2d0-4b096554cac2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f5dbb8ee-a3ac-45d5-8565-cb868d8dcacc"}}}}, {"uuid": "1075be6b-e219-473d-9788-5f8402ae986e", "name": "bc79087e-5b48-4f36-9565-0f6d889bf24a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3439175585507637, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8866404836608991, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b96068ac-8105-447b-87cc-d2dcd76627e9", "name": "c457924a-fe6c-41c2-8832-7e0dc9f8d167", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1075be6b-e219-473d-9788-5f8402ae986e"}}}]}, {"uuid": "de3a713a-805a-4f59-becb-1cf5a6bbf5bc", "name": "load_p1rlv17033_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfa28657-cd8e-4700-a189-83e021f77bee"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b96068ac-8105-447b-87cc-d2dcd76627e9"}}}}, {"uuid": "2b1955b1-62bc-4564-8fe6-35dd39d88f5b", "name": "aa89ade7-79fb-43ce-8080-59b9f57aaa03_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3439175585507637, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8866404836608991, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7b42fd45-8da2-44d9-8b3e-fcb8e439a5d7", "name": "c8b90da3-b732-4357-bb28-78406c91eb32", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2b1955b1-62bc-4564-8fe6-35dd39d88f5b"}}}]}, {"uuid": "abb1148b-4003-47e2-ac8c-b32e08454fca", "name": "load_p1rlv17033_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfa28657-cd8e-4700-a189-83e021f77bee"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7b42fd45-8da2-44d9-8b3e-fcb8e439a5d7"}}}}, {"uuid": "17e5dbaa-c769-4f03-b356-192bf295035c", "name": "191cfe11-c72d-45aa-a247-60bed4ebb772_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7956093485713416, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7629429667228578, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d53f386f-2df8-408d-9e51-aff2cce29ac9", "name": "e265aef2-bb12-431c-92b3-2353267e0ac9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "17e5dbaa-c769-4f03-b356-192bf295035c"}}}]}, {"uuid": "1002f375-c3f6-45cf-b9b1-cc1a38a48e60", "name": "load_p1rlv17059_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "92aff718-b70f-4ea4-b38b-fae69a470c58"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d53f386f-2df8-408d-9e51-aff2cce29ac9"}}}}, {"uuid": "f94714fc-b314-4c3b-a711-f8834d368c24", "name": "dc84c758-bc43-4d6e-8462-d0abdf0f5e91_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7956093485713416, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7629429667228578, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "845cf96b-513d-4834-8ba3-17f15390fbea", "name": "c47f2ca8-56e9-4890-bbe9-6a4ddf9cf345", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f94714fc-b314-4c3b-a711-f8834d368c24"}}}]}, {"uuid": "ffdaa977-c02b-4879-b639-18cc117150d5", "name": "load_p1rlv17059_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "92aff718-b70f-4ea4-b38b-fae69a470c58"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "845cf96b-513d-4834-8ba3-17f15390fbea"}}}}, {"uuid": "770ec631-db34-4b22-a286-0fe45386701a", "name": "352c6d36-cef7-4877-a5a5-ec706ac1b8aa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.969457727539003, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.134389471891055, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "70d017a7-e7af-4d32-a9ae-897881641612", "name": "02b55e58-5a28-4d94-be7a-8c095ffa4eb6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "770ec631-db34-4b22-a286-0fe45386701a"}}}]}, {"uuid": "d95d2f6f-c70e-4459-a852-b572c68f28be", "name": "load_p1rlv17063_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19130741-0fe1-4a12-8a55-96355609bccb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "70d017a7-e7af-4d32-a9ae-897881641612"}}}}, {"uuid": "e6f2358b-ab56-4521-bcd1-15842e7b60ed", "name": "e79d1d03-c7e9-4c3b-b406-1223c85893ee_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.969457727539003, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.134389471891055, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a79830b3-943c-443d-a83d-447940d123f8", "name": "a4593dd7-d942-489a-8b71-eb99f9f1c908", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e6f2358b-ab56-4521-bcd1-15842e7b60ed"}}}]}, {"uuid": "bd0c6050-31cd-4e76-be8f-e483919759fd", "name": "load_p1rlv17063_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19130741-0fe1-4a12-8a55-96355609bccb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a79830b3-943c-443d-a83d-447940d123f8"}}}}, {"uuid": "33fe1973-a21a-4bc8-a818-d2c6639e7533", "name": "714f5256-64f5-4ab0-9b88-7cc020a3ccc9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.922263051512463, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2402658775286277, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a2d73a08-0e8b-4a47-a01e-a4f6632a470b", "name": "c2a74168-1a0f-4204-b165-0b081563d7b0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "33fe1973-a21a-4bc8-a818-d2c6639e7533"}}}]}, {"uuid": "f7903183-a52b-4683-8bad-4d0773ce9007", "name": "load_p1rlv17069_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd48a076-5f8f-426a-b294-183700d1a123"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a2d73a08-0e8b-4a47-a01e-a4f6632a470b"}}}}, {"uuid": "4c5af2eb-8b35-4734-9ad2-817b3ccb6d3b", "name": "70c41a48-a083-4243-ab1d-5fd668ee1edb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.922263051512463, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2402658775286277, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5a08b7b6-26cd-4f5b-a3ef-7ad7476b292e", "name": "f6d0aaa9-95e7-47e3-bf15-8b5ba3ce733e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4c5af2eb-8b35-4734-9ad2-817b3ccb6d3b"}}}]}, {"uuid": "f578c8c4-fa8b-4d9e-9f07-4c804ebfbc3f", "name": "load_p1rlv17069_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd48a076-5f8f-426a-b294-183700d1a123"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5a08b7b6-26cd-4f5b-a3ef-7ad7476b292e"}}}}, {"uuid": "51f7d4f2-a266-4996-b80f-15338891adf1", "name": "1d06895b-42d8-4db3-8829-f756b36c3c76_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5365841293045384, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.535303100231416, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a0d7f2db-b0fe-45ca-8542-f5eedcbeab49", "name": "9de10aa4-24d6-4bf3-9b8a-57d7aa0b9870", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "51f7d4f2-a266-4996-b80f-15338891adf1"}}}]}, {"uuid": "c9d48c81-6c8c-490f-95dd-1ce2d8a0ae45", "name": "load_p1rlv17106_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5439f343-8176-4d92-99d4-bb9209817f6b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a0d7f2db-b0fe-45ca-8542-f5eedcbeab49"}}}}, {"uuid": "20a98f1d-cf86-4461-a79d-c2dc156064c9", "name": "21ab1c11-8243-4bec-8fd0-3e7c7fd1de67_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5365841293045384, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.535303100231416, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6d94ddb0-3dbb-4efe-acff-dfb997f912cd", "name": "12fe9e74-038d-4364-9813-9f3e5ad55a03", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "20a98f1d-cf86-4461-a79d-c2dc156064c9"}}}]}, {"uuid": "50ad8a88-7520-4cdc-ba7d-ff0d57068c1c", "name": "load_p1rlv17106_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5439f343-8176-4d92-99d4-bb9209817f6b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6d94ddb0-3dbb-4efe-acff-dfb997f912cd"}}}}, {"uuid": "8b36242e-6bd4-47a0-9b19-7bb52e4578f9", "name": "9cb374a1-06ea-4585-bed0-445caf08d05e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2874196130666418, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9219654181970236, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f6e11f36-1899-48eb-96e7-39b8e13aa53b", "name": "f1c45f95-14b0-4fe5-9278-4a588750554a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8b36242e-6bd4-47a0-9b19-7bb52e4578f9"}}}]}, {"uuid": "565a8900-809c-4de8-b22c-475b29b2a605", "name": "load_p1rlv17319_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9778ed5-f0c0-44de-b0d4-60659a54fa3b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f6e11f36-1899-48eb-96e7-39b8e13aa53b"}}}}, {"uuid": "ec253a61-eec6-4c57-9c65-7249402675e7", "name": "e5099b75-2916-449c-8052-583f32c20b53_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2874196130666418, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9219654181970236, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e1f66be1-8a64-4033-a446-a9cc4fd4d9c6", "name": "70dce794-59c9-46b4-a978-c63bcdd5170d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ec253a61-eec6-4c57-9c65-7249402675e7"}}}]}, {"uuid": "cf9a64fa-bfdf-49fd-9f95-5e01a1c9fb3b", "name": "load_p1rlv17319_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9778ed5-f0c0-44de-b0d4-60659a54fa3b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e1f66be1-8a64-4033-a446-a9cc4fd4d9c6"}}}}, {"uuid": "09753040-0e6b-4a7d-a2b7-32b34a52ae43", "name": "2c09bf7e-ea77-4ef0-8287-7831413ec4c3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.685213211371405, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7584354740780123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a6a57f47-e0a0-4271-bb83-ecadd10e445b", "name": "114d8058-bcfa-4ee0-b269-3af3608c887d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "09753040-0e6b-4a7d-a2b7-32b34a52ae43"}}}]}, {"uuid": "b8cc302b-3bc8-4b2e-8269-f92fa01fa7c1", "name": "load_p1rlv17320_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79991b02-c0f1-4b9b-a55e-e9b4ff7c17d9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a6a57f47-e0a0-4271-bb83-ecadd10e445b"}}}}, {"uuid": "1339bbd1-699a-457b-86a0-9548e35bffc5", "name": "448ee8a0-22e7-4fe1-803c-4b11107f1619_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.685213211371405, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7584354740780123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "657035af-f4c6-4e4a-9f57-3089797e7891", "name": "2b655e73-8a0e-402c-984b-80f6099048e2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1339bbd1-699a-457b-86a0-9548e35bffc5"}}}]}, {"uuid": "c7144a5c-c9bb-4a10-bd62-2874b0420620", "name": "load_p1rlv17320_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79991b02-c0f1-4b9b-a55e-e9b4ff7c17d9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "657035af-f4c6-4e4a-9f57-3089797e7891"}}}}, {"uuid": "d4da6f6f-0243-45bf-93a6-017baa6f7913", "name": "f760ccd8-5c94-4f50-b4f4-915c44375080_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.651721747239447, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.750976002130125, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0837056c-39b6-4fdb-8d38-7dbdb9184762", "name": "df662db3-42c8-4c75-8d37-5391bef3944e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d4da6f6f-0243-45bf-93a6-017baa6f7913"}}}]}, {"uuid": "239d1bff-f9a1-4edc-bc72-e064e2f577c4", "name": "load_p1rlv17321_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce41ac7c-06c5-435a-957d-c9dda83c1893"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0837056c-39b6-4fdb-8d38-7dbdb9184762"}}}}, {"uuid": "37295526-b584-45ad-92f9-39939c9a4ebf", "name": "a74f6ab6-e8f9-4028-8cf2-8b6085846259_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.651721747239447, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.750976002130125, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c7f44cb0-11c8-4f88-9771-59efe5287350", "name": "e5470d52-e1cb-4b55-973e-749cfe5b1e86", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "37295526-b584-45ad-92f9-39939c9a4ebf"}}}]}, {"uuid": "1b3480aa-cbb6-4442-a899-573ac7b41435", "name": "load_p1rlv17321_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce41ac7c-06c5-435a-957d-c9dda83c1893"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c7f44cb0-11c8-4f88-9771-59efe5287350"}}}}, {"uuid": "235d75c4-2295-44ab-8df0-5cd891f92385", "name": "7e97fd9b-b041-41f6-ae16-1532d47e3390_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.737986692242784, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8906640815201406, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "903aae3b-fcbc-44bf-8758-2d1c89fe8b18", "name": "61bd174e-2446-48ac-a280-97adb323c08d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "235d75c4-2295-44ab-8df0-5cd891f92385"}}}]}, {"uuid": "1535ffaa-5001-4f52-8f80-2852bafe92ad", "name": "load_p1rlv17325_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b96606c-9336-4299-be8d-295c84943a9d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "903aae3b-fcbc-44bf-8758-2d1c89fe8b18"}}}}, {"uuid": "d0a83ebe-9d26-4422-a27d-d362ea0d2275", "name": "15f958a3-c7c3-47b4-9e02-9681fef221f7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.737986692242784, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8906640815201406, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6881f547-3f6e-4678-83c3-557c9ad34cfd", "name": "36aa2e1a-aabb-49f5-b74b-8dd8cb98a9ae", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d0a83ebe-9d26-4422-a27d-d362ea0d2275"}}}]}, {"uuid": "4970ad7b-7fdc-4b8e-a6d9-fb76fc0b981c", "name": "load_p1rlv17325_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b96606c-9336-4299-be8d-295c84943a9d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6881f547-3f6e-4678-83c3-557c9ad34cfd"}}}}, {"uuid": "f8cd7541-9f9c-4029-9050-ac9ae9981b61", "name": "3dd2dcda-5b20-4521-9e1c-533b0f4e2d7d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6912886909314806, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4972799611827758, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ef49f829-a2f1-487a-92ae-0a19154aead2", "name": "a1cb7b13-e07d-4b3a-b665-a622a752c384", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8cd7541-9f9c-4029-9050-ac9ae9981b61"}}}]}, {"uuid": "e86268fa-8ad4-49fe-8411-13873c95c5c1", "name": "load_p1rlv17326_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ceb2d77-2da7-44df-9f28-69ed35835775"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ef49f829-a2f1-487a-92ae-0a19154aead2"}}}}, {"uuid": "cf2f9671-7166-4bed-b0e5-cdfe1a3e3407", "name": "b001c8e1-fbe3-4315-9012-5d7b53544280_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6912886909314806, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4972799611827758, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d12cd93b-3287-4394-ad01-9fe19d458e21", "name": "4194c18c-2067-4de4-a9b2-b7305de03e5d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cf2f9671-7166-4bed-b0e5-cdfe1a3e3407"}}}]}, {"uuid": "04c053de-c88f-429f-8ab5-3ded39fef042", "name": "load_p1rlv17326_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ceb2d77-2da7-44df-9f28-69ed35835775"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d12cd93b-3287-4394-ad01-9fe19d458e21"}}}}, {"uuid": "dcad649d-8185-48c6-b750-d5f463a7a21f", "name": "f871a1d5-2c75-44b5-9c2b-723355efeb26_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8996652652050283, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6342298940221502, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f010069f-ea35-4345-9daa-b8507cb0699f", "name": "ebbd0d99-b2f3-4e55-be22-f03e43cb34d0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dcad649d-8185-48c6-b750-d5f463a7a21f"}}}]}, {"uuid": "af64a22c-b338-4f1d-99e4-adc3f6ce48cd", "name": "load_p1rlv17328_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a43eb022-d5e0-47c8-aa36-6ca0d212ab07"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f010069f-ea35-4345-9daa-b8507cb0699f"}}}}, {"uuid": "33b5235b-19af-4e31-8616-eeb491886df0", "name": "59a7faed-ede4-4c0c-8cd0-53d4d59b4b4b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8996652652050283, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6342298940221502, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "362f1e4e-e82c-4263-ad7a-1736626d9256", "name": "a3751d2c-9cb4-4c6e-8aa2-9609fffb808c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "33b5235b-19af-4e31-8616-eeb491886df0"}}}]}, {"uuid": "a5b20244-ff63-44b8-8128-e65520ab9992", "name": "load_p1rlv17328_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a43eb022-d5e0-47c8-aa36-6ca0d212ab07"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "362f1e4e-e82c-4263-ad7a-1736626d9256"}}}}, {"uuid": "502af279-7eef-4cd6-bc11-335a2d01c6a6", "name": "23f5e75d-4b35-4623-8af6-52bc6d890237_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.965154260277072, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307595255595673, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "03e0b75d-f196-4789-b772-0d0bfcdd7467", "name": "05f90df4-2094-4b44-bcff-622bcb412f47", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "502af279-7eef-4cd6-bc11-335a2d01c6a6"}}}]}, {"uuid": "421c3101-a04f-42d9-8430-d2215058afef", "name": "load_p1rlv17329_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61ef37c1-f14f-4b79-a428-d51a6f0d076a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "03e0b75d-f196-4789-b772-0d0bfcdd7467"}}}}, {"uuid": "bf4e7f5c-06b7-48c3-917d-f780ba6569af", "name": "2c20c9c8-ab35-439c-95b8-88a2bec362ee_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.965154260277072, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307595255595673, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4a990b69-4720-4896-a637-88307f139368", "name": "1c6d8545-b014-47e2-b39c-5c9b64403991", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bf4e7f5c-06b7-48c3-917d-f780ba6569af"}}}]}, {"uuid": "2d364ee8-89df-47d3-925d-bc76de773f9f", "name": "load_p1rlv17329_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61ef37c1-f14f-4b79-a428-d51a6f0d076a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4a990b69-4720-4896-a637-88307f139368"}}}}, {"uuid": "73300fee-aac5-4356-8768-a4c425db1b5c", "name": "d1e15fa3-2da0-4791-91b5-615a9f354c5c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.356365911619733, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.9144830945937485, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f87347ec-7156-4651-b922-6d73776421c8", "name": "b99d852e-feb2-4e27-bfa0-3d0a37d1b68f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "73300fee-aac5-4356-8768-a4c425db1b5c"}}}]}, {"uuid": "e33a1b8c-05d1-4e88-aea1-642e6a4b9283", "name": "load_p1rlv17330_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48ad7bb0-8dd7-457a-b77d-6db2071c2fe7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f87347ec-7156-4651-b922-6d73776421c8"}}}}, {"uuid": "e730a872-297b-4984-9f32-ea11e1223742", "name": "bd4c8eca-463f-417e-ad06-5b4f0592da20_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.356365911619733, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.9144830945937485, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "521fd1db-d248-4a5c-837d-8765dbe26545", "name": "de103423-d263-4bc4-8e5f-616aef1079b5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e730a872-297b-4984-9f32-ea11e1223742"}}}]}, {"uuid": "d780e515-74d8-40c6-a7b7-c9071c69af6d", "name": "load_p1rlv17330_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48ad7bb0-8dd7-457a-b77d-6db2071c2fe7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "521fd1db-d248-4a5c-837d-8765dbe26545"}}}}, {"uuid": "1bfcde87-02bf-4ce9-8ed4-7209cb2e19d7", "name": "0295af67-ecd0-486b-af5e-69d9a5cdfe46_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.255903801273714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9789336651099453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "80309df0-588d-49c0-ad64-99b3de9933af", "name": "e0617d38-b588-4c31-9ee1-be55b341fb67", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1bfcde87-02bf-4ce9-8ed4-7209cb2e19d7"}}}]}, {"uuid": "366eed2b-9cc7-4cc8-9a6d-f23d8620b83d", "name": "load_p1rlv17333_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33b66eb9-3b21-4f92-b19b-6a0eef4134d8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "80309df0-588d-49c0-ad64-99b3de9933af"}}}}, {"uuid": "6ae4fcd8-c7f9-45bb-aac8-956b026448cc", "name": "cff104dd-acb7-4b9a-91d7-e355b76ea6b7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.255903801273714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9789336651099453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "abf2ae54-b1d6-4d72-a05f-98f931da19aa", "name": "bd7f4c86-5f03-4e9d-a761-526843704029", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6ae4fcd8-c7f9-45bb-aac8-956b026448cc"}}}]}, {"uuid": "b58c0573-6035-407e-b046-33984fd2092c", "name": "load_p1rlv17333_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33b66eb9-3b21-4f92-b19b-6a0eef4134d8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "abf2ae54-b1d6-4d72-a05f-98f931da19aa"}}}}, {"uuid": "38389ae1-540a-4b72-aa42-af02254ae37f", "name": "657c8f54-5aaa-4854-8bec-9057bdcd69c8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4460841500077097, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.15562665537022718, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dee75f5a-8383-4ed1-9bcb-b2bcf07eb44c", "name": "5f368daa-20fb-4310-ab20-38e603dd0dda", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "38389ae1-540a-4b72-aa42-af02254ae37f"}}}]}, {"uuid": "76335f13-60ce-41e1-9026-922a1d9ecad6", "name": "load_p1rlv17334_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4970bc03-bc57-4a42-b0cb-66002af1709e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dee75f5a-8383-4ed1-9bcb-b2bcf07eb44c"}}}}, {"uuid": "7f4ebfe0-40c5-4bc9-8d1b-595aba889280", "name": "d1f4d03d-b29c-4558-a26c-8a63b1703fbb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4460841500077097, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.15562665537022718, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f40e8fbd-f09a-4cdc-8726-aadbe95b7361", "name": "9e000e2d-2767-4d2f-9a5a-ebc1aace4bc6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7f4ebfe0-40c5-4bc9-8d1b-595aba889280"}}}]}, {"uuid": "4f7252ce-8e0f-41f4-ae5f-1e75102a5f20", "name": "load_p1rlv17334_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4970bc03-bc57-4a42-b0cb-66002af1709e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f40e8fbd-f09a-4cdc-8726-aadbe95b7361"}}}}, {"uuid": "7770234d-62d4-4e13-93b8-9faa62388024", "name": "4c0ed79f-20c9-4da8-9fc7-9b40e54ee282_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.359977223622412, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2969054470018346, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d1ccdca0-093d-4453-a542-dfb77fd0c26f", "name": "735ac888-54bc-4df2-8549-bcd8f865f7ae", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7770234d-62d4-4e13-93b8-9faa62388024"}}}]}, {"uuid": "d7fc5468-3384-4827-b882-e6713879f684", "name": "load_p1rlv17336_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b645969-9136-42a9-b5ac-7d2f1ff71959"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d1ccdca0-093d-4453-a542-dfb77fd0c26f"}}}}, {"uuid": "bc11a223-15f9-48b8-b73b-8370380bc9fd", "name": "19cfeaa7-2b0c-4f67-ac42-d0300df652fb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.359977223622412, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2969054470018346, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e69fe531-0740-4468-9fe7-288bd3769e5f", "name": "5ff19b73-e67a-42e3-9192-f3a4f27649df", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bc11a223-15f9-48b8-b73b-8370380bc9fd"}}}]}, {"uuid": "8396bf77-6765-45f5-82e9-242a84e70f48", "name": "load_p1rlv17336_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b645969-9136-42a9-b5ac-7d2f1ff71959"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e69fe531-0740-4468-9fe7-288bd3769e5f"}}}}, {"uuid": "0f8feaae-af20-4ec3-8b23-e952cb4a6d6e", "name": "83159870-f9d3-442a-97aa-8a42631c32f5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.157838539018536, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.1846823736377714, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "98bd2f16-26b5-47f5-87b1-b3b75c6eb722", "name": "b53c729d-dc99-403d-9bfb-61ee0f06c0ac", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0f8feaae-af20-4ec3-8b23-e952cb4a6d6e"}}}]}, {"uuid": "6e1b9ad7-c909-4865-8432-e7ff483d75c1", "name": "load_p1rlv17337_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5d7049e-9d30-474c-9033-3ad9b4487f7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "98bd2f16-26b5-47f5-87b1-b3b75c6eb722"}}}}, {"uuid": "23ea3d41-4fb0-400f-b006-de183516f61c", "name": "b9274f04-6d81-4bdc-b6b4-9d251c80c79f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.157838539018536, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.1846823736377714, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5e6a5815-3cb1-4b23-9e57-d203e5d85c62", "name": "97315a0a-6423-4943-9a7c-8b41539a03cb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "23ea3d41-4fb0-400f-b006-de183516f61c"}}}]}, {"uuid": "684f5533-f848-4fe6-afd9-8445ebb46174", "name": "load_p1rlv17337_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5d7049e-9d30-474c-9033-3ad9b4487f7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5e6a5815-3cb1-4b23-9e57-d203e5d85c62"}}}}, {"uuid": "5c054edd-c1ec-4d63-b7fd-2207354a66cc", "name": "0b5b75ef-8e44-46a6-a040-396856a4ca71_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.241859724602562, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.250877899038581, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "62397ab6-6a05-426d-8dc3-584c053fff44", "name": "883f491d-1400-4a65-a1fa-92903e5d220f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5c054edd-c1ec-4d63-b7fd-2207354a66cc"}}}]}, {"uuid": "f32efdb4-559e-490e-b395-2486691c556e", "name": "load_p1rlv17338_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "331389ab-5d04-4648-83b4-3043198c774f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "62397ab6-6a05-426d-8dc3-584c053fff44"}}}}, {"uuid": "69d97f87-0ce5-4dad-84fe-c0820689c482", "name": "5c9344f5-ed54-4a4e-9556-05651f149697_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.241859724602562, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.250877899038581, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bdd66b0e-efdd-4dbb-a880-a563704bab7f", "name": "dc6d0468-96f6-4234-8881-da3ca3c8a732", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "69d97f87-0ce5-4dad-84fe-c0820689c482"}}}]}, {"uuid": "24b04968-809c-4f9e-82c9-2393f24ced06", "name": "load_p1rlv17338_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "331389ab-5d04-4648-83b4-3043198c774f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bdd66b0e-efdd-4dbb-a880-a563704bab7f"}}}}, {"uuid": "7d6f6682-4b16-4d78-8341-02dff6a588fe", "name": "5fcda203-655d-453f-95e9-d856be4dda50_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.949137985829372, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.575540256876006, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e10dccc6-c7b1-47cd-88f9-ba4e865bb912", "name": "349bdcdc-edbb-489d-acac-32c5c19e07d2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7d6f6682-4b16-4d78-8341-02dff6a588fe"}}}]}, {"uuid": "72c9ade7-113c-41e7-9225-8cff048b643b", "name": "load_p1rlv17702_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7acb4e7d-cb06-4848-952d-7c68bb34b6db"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e10dccc6-c7b1-47cd-88f9-ba4e865bb912"}}}}, {"uuid": "be52c1ba-3322-4d4f-a639-ed481cdafb06", "name": "1c903b5f-69b3-4a5f-826c-408a365c6bd8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.949137985829372, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.575540256876006, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "450b1b56-3277-4891-bb72-afcc79768b33", "name": "2789a382-ddb9-43ab-bc92-aec08e51abb1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "be52c1ba-3322-4d4f-a639-ed481cdafb06"}}}]}, {"uuid": "5fc87cb6-ada6-4067-b553-daebcf1caece", "name": "load_p1rlv17702_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7acb4e7d-cb06-4848-952d-7c68bb34b6db"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "450b1b56-3277-4891-bb72-afcc79768b33"}}}}, {"uuid": "54432679-b6b2-4d78-ab72-45c674f6e4c7", "name": "cbff83cc-f4cb-4058-a0fc-21d41805ea63_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.965154260277072, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307595255595673, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b029dfda-8738-4211-924a-5b1ccf2b13c9", "name": "e0b5bc66-cdee-4562-9a95-1f343869399a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "54432679-b6b2-4d78-ab72-45c674f6e4c7"}}}]}, {"uuid": "f405c86c-6283-4e82-94df-f7684c805921", "name": "load_p1rlv17781_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a52db2ff-b782-40c1-828a-c65f6929b2fc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b029dfda-8738-4211-924a-5b1ccf2b13c9"}}}}, {"uuid": "1e999895-719f-4b49-b2c7-7a104578adb6", "name": "8bc0e0ee-ff40-4d1e-baee-9f86e3507dbf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.965154260277072, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307595255595673, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2079d6c3-7144-4c92-bc10-aeffc20e685f", "name": "9a9e85ad-5a1d-44fb-b0e2-22b93b6b85b5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1e999895-719f-4b49-b2c7-7a104578adb6"}}}]}, {"uuid": "a61d4b03-911d-42f1-9f8d-c407beccdbeb", "name": "load_p1rlv17781_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a52db2ff-b782-40c1-828a-c65f6929b2fc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2079d6c3-7144-4c92-bc10-aeffc20e685f"}}}}, {"uuid": "3d87410e-83fa-4503-a32b-42bffa2ade70", "name": "9ebe8467-6d47-4b96-aa2a-cc848e2cf97e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.4509454152189125, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9978822313633423, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "198a11c5-9d1e-4caf-a3fd-831192a81b57", "name": "846dcd18-3cee-466e-83b5-1959f08516b3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3d87410e-83fa-4503-a32b-42bffa2ade70"}}}]}, {"uuid": "48206521-093e-4330-82af-1b8be5c79b02", "name": "load_p1rlv17787_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c9c1d9f-eeff-454f-b3d0-7e7de837694c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "198a11c5-9d1e-4caf-a3fd-831192a81b57"}}}}, {"uuid": "163ec51c-f0c1-492c-9666-21946210daaf", "name": "29b335a2-eaf9-48da-817a-17d7c348ac1d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.4509454152189125, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9978822313633423, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8058e3d1-c5b1-4e29-bd83-99287167a6c4", "name": "e1e33dda-f889-4d56-993e-273a46436294", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "163ec51c-f0c1-492c-9666-21946210daaf"}}}]}, {"uuid": "a7bfce45-0f3d-4e66-b3ea-051b6d8c0cf3", "name": "load_p1rlv17787_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c9c1d9f-eeff-454f-b3d0-7e7de837694c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8058e3d1-c5b1-4e29-bd83-99287167a6c4"}}}}, {"uuid": "7b857081-2d81-4bc4-a793-593d6a41b721", "name": "69e968b9-c607-4afc-8481-09a084bce421_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8534881847076217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.812795269620709, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0adc15f9-14b0-4e0c-b445-d886b5f3c16e", "name": "a0a04716-5d5d-4c1e-aa2b-43c7fad31167", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b857081-2d81-4bc4-a793-593d6a41b721"}}}]}, {"uuid": "78c99f01-deb9-4359-9ee0-bb0448e0955b", "name": "load_p1rlv17798_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9dba02d-086c-4906-9c6f-86532e3384c0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0adc15f9-14b0-4e0c-b445-d886b5f3c16e"}}}}, {"uuid": "8555fc92-e9ab-4ffe-b86c-713c278c23fb", "name": "ac94db1f-9834-4f23-8a46-337a25965209_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8534881847076217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.812795269620709, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0cc910e3-3490-41d8-bbf8-a3487362ef2d", "name": "4a6c21e0-2ca4-442d-8d28-1b9ffe7f3dcf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8555fc92-e9ab-4ffe-b86c-713c278c23fb"}}}]}, {"uuid": "aa5c1c56-5a37-4ada-9466-b39ca4a4ea34", "name": "load_p1rlv17798_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9dba02d-086c-4906-9c6f-86532e3384c0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0cc910e3-3490-41d8-bbf8-a3487362ef2d"}}}}, {"uuid": "5f9ef80b-6b91-445d-a78e-777ec0e81b50", "name": "f92c31a2-9402-4e54-9e0f-1de381a81ec1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6844632506969115, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4071315730781585, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d7df6801-627e-4f73-ad3d-f2e3d628eff9", "name": "9efd73ab-497f-47f0-8980-6551b60ee625", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5f9ef80b-6b91-445d-a78e-777ec0e81b50"}}}]}, {"uuid": "3f9bdf0e-f89f-46e9-a0d2-587640eb27bc", "name": "load_p1rlv17810_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3887a879-0783-4703-8a24-32b7e3b4f39d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d7df6801-627e-4f73-ad3d-f2e3d628eff9"}}}}, {"uuid": "14d19e97-d917-49f8-8726-06d23e6a61f8", "name": "58baa9eb-f123-4e37-8b30-8735fcd7f441_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6844632506969115, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4071315730781585, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "445ea327-9707-4c4e-b794-9288514689f9", "name": "52f7ab9d-9e50-48b6-81f3-75cd2228557b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "14d19e97-d917-49f8-8726-06d23e6a61f8"}}}]}, {"uuid": "2f28be03-818a-4f93-af62-e804e4f8052b", "name": "load_p1rlv17810_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3887a879-0783-4703-8a24-32b7e3b4f39d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "445ea327-9707-4c4e-b794-9288514689f9"}}}}, {"uuid": "e14a7e0c-44e6-4636-9145-5902e8696f58", "name": "3454769d-7d63-4a7f-9fe0-6062947119bf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.136651452497737, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.586908988148888, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "25e771ac-e957-447e-8569-3b5b9a12e970", "name": "5674eef4-41c9-43f4-bbe8-54b74a5533d8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e14a7e0c-44e6-4636-9145-5902e8696f58"}}}]}, {"uuid": "c72a25b6-0826-41ad-a0d8-f7b0c4265083", "name": "load_p1rlv17847_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f7776e4-a81f-48d2-b3c0-d70bfa48164e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "25e771ac-e957-447e-8569-3b5b9a12e970"}}}}, {"uuid": "4cf6afae-55af-4626-8b4e-7dbefc832603", "name": "330a397d-5aff-4cbf-aff8-b9fcc9e7f79f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.136651452497737, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.586908988148888, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "35baf397-b50d-4e62-9f61-77b4a7ea8418", "name": "444cc47d-e24e-4637-85d4-6a37566cd207", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4cf6afae-55af-4626-8b4e-7dbefc832603"}}}]}, {"uuid": "eee5393e-00d6-46c7-b18b-a0f91f0d99fe", "name": "load_p1rlv17847_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f7776e4-a81f-48d2-b3c0-d70bfa48164e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "35baf397-b50d-4e62-9f61-77b4a7ea8418"}}}}, {"uuid": "6e098042-e93f-4831-8ac8-ae75c7f70985", "name": "ef62be26-4c67-45c8-99db-2e14e7c2275b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3135149757913545, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7371070877725675, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7a47240f-01a4-41ee-b4b9-72dc87b5daec", "name": "ceca9648-b1df-47a9-9014-80d9e01f1dd8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6e098042-e93f-4831-8ac8-ae75c7f70985"}}}]}, {"uuid": "5498629b-d009-4516-acf5-664b97cf89c2", "name": "load_p1rlv17857_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0827675c-2467-403d-822e-5f74cd6296c5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7a47240f-01a4-41ee-b4b9-72dc87b5daec"}}}}, {"uuid": "a47d8cd3-ed11-4b5f-9db3-c4a0034a9ca4", "name": "fb659191-f009-41b2-b21f-120fa0247c8f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3135149757913545, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7371070877725675, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fca87ce0-49b3-4835-820a-8be2bcae6903", "name": "251ff752-b29c-40ce-bba4-4314bc46db73", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a47d8cd3-ed11-4b5f-9db3-c4a0034a9ca4"}}}]}, {"uuid": "c858a7f0-8223-4efb-a2d9-b2882fb6d971", "name": "load_p1rlv17857_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0827675c-2467-403d-822e-5f74cd6296c5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fca87ce0-49b3-4835-820a-8be2bcae6903"}}}}, {"uuid": "785da82f-5373-452b-8227-90ab120ca7b4", "name": "56bf38fa-cd89-4dbe-8b53-49af2e32ed1f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.443583112785006, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2576306570382033, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fef70936-b654-42b2-be1b-86b55a67b30a", "name": "79526ef0-8a1f-4b6e-843f-8bb1698ea65f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "785da82f-5373-452b-8227-90ab120ca7b4"}}}]}, {"uuid": "a4d5dbc3-0330-411d-8a82-6a7737083b0e", "name": "load_p1rlv17876_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75e55237-b847-4fb7-a141-a0771bd868c6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fef70936-b654-42b2-be1b-86b55a67b30a"}}}}, {"uuid": "1e9a1961-e7a9-4146-80c2-cf66003e17ba", "name": "72125487-3fd7-4146-bfb6-029c8fb66e97_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.443583112785006, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2576306570382033, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b1747e1a-b340-4027-b5b4-cdc0451196ad", "name": "66e84d45-331d-4185-a59d-2323e03033d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1e9a1961-e7a9-4146-80c2-cf66003e17ba"}}}]}, {"uuid": "57dc88b8-3fa0-4d70-9b9e-b9d84be074a7", "name": "load_p1rlv17876_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75e55237-b847-4fb7-a141-a0771bd868c6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b1747e1a-b340-4027-b5b4-cdc0451196ad"}}}}, {"uuid": "2a816c78-b7c5-4dae-86bc-556d575808b4", "name": "f8759381-73dd-4b2d-9110-80d5e846c70e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1426015471760884, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5928311844731246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cc7bc10a-874e-4459-af46-b5b0f7ad1bc6", "name": "93601803-22d6-4ad7-bb7d-e7211b2a59ff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2a816c78-b7c5-4dae-86bc-556d575808b4"}}}]}, {"uuid": "7a66ce02-8f45-4802-ae36-c25ff587b520", "name": "load_p1rlv17877_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f44b0293-61e5-4054-b2d7-4a113df92b3c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cc7bc10a-874e-4459-af46-b5b0f7ad1bc6"}}}}, {"uuid": "0c3e0615-8667-4df0-b786-134737220183", "name": "e87fd7ce-4d9e-463c-8d0a-3c500e9b8401_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1426015471760884, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5928311844731246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2efdaf05-7c0b-491c-9674-03bc78329797", "name": "f88041bf-92ed-424b-820b-e0481e549c88", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0c3e0615-8667-4df0-b786-134737220183"}}}]}, {"uuid": "613a4a65-8be2-4936-a8bd-f65d054605f7", "name": "load_p1rlv17877_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f44b0293-61e5-4054-b2d7-4a113df92b3c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2efdaf05-7c0b-491c-9674-03bc78329797"}}}}, {"uuid": "747c2cc6-2d86-4f59-9ca8-530bb0f6ba8d", "name": "46b5cdf4-3ff2-4a1c-bef2-2d57a001d3ef_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.67620786252276, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6753067705079763, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0af8c976-a6e0-4470-bc59-1d8800943c1a", "name": "1d4b0369-7042-401d-a28a-16884ca6b2c7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "747c2cc6-2d86-4f59-9ca8-530bb0f6ba8d"}}}]}, {"uuid": "e3f310df-f0c4-4b89-9432-0bab91f2241d", "name": "load_p1rlv17897_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f74f217-4765-406d-9646-d8f46377ef0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0af8c976-a6e0-4470-bc59-1d8800943c1a"}}}}, {"uuid": "0c405577-dccd-493a-bd4b-e52011412b9e", "name": "deab8b54-668c-47ff-8a8c-9d158ba82837_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.67620786252276, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6753067705079763, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c33af26c-c73a-4bf3-8252-dd6b48f69ce1", "name": "bd9a4bb0-985a-4626-9645-2d8b3c4c0fec", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0c405577-dccd-493a-bd4b-e52011412b9e"}}}]}, {"uuid": "3ac79b34-2d50-40be-baa0-efbb85f6253d", "name": "load_p1rlv17897_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f74f217-4765-406d-9646-d8f46377ef0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c33af26c-c73a-4bf3-8252-dd6b48f69ce1"}}}}, {"uuid": "673954b0-f374-4cea-81d2-77aae21ac239", "name": "c7ca9f33-6dee-4b99-ab2e-c6fd7b8f141c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3841896439528762, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.62886585412856, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "43870935-1fbe-4419-a912-eabaf277738d", "name": "1f44b787-71df-4d82-892f-ed486384c677", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "673954b0-f374-4cea-81d2-77aae21ac239"}}}]}, {"uuid": "f146f258-d046-4e2f-92cf-fa17ae5d53a8", "name": "load_p1rlv17909_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab733d49-bb36-4631-8824-1967f98f758a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "43870935-1fbe-4419-a912-eabaf277738d"}}}}, {"uuid": "b0f16155-341f-4fef-9b89-4ba76fa3fa9b", "name": "184ed837-46d1-48b6-9e40-41454e4f4529_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3841896439528762, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.62886585412856, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0cc76fc8-659e-45fa-8c82-49735e94aa6e", "name": "756b0c1d-4183-4f16-93fb-62c0a6c14c1b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b0f16155-341f-4fef-9b89-4ba76fa3fa9b"}}}]}, {"uuid": "8b089298-c576-4ac5-8380-4d3a995dd365", "name": "load_p1rlv17909_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab733d49-bb36-4631-8824-1967f98f758a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0cc76fc8-659e-45fa-8c82-49735e94aa6e"}}}}, {"uuid": "85580e6f-4336-4378-8593-aa5e7f997af6", "name": "c78d97da-dbb2-40cc-a767-670b78cef609_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5290895920961123, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.36247808422876804, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "737497c3-2c01-4ab2-a5db-da56979d37c2", "name": "ab66c99b-9660-48d5-a102-d31d5ad73bc4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "85580e6f-4336-4378-8593-aa5e7f997af6"}}}]}, {"uuid": "554a2fbd-8de1-491f-9962-641362d00fec", "name": "load_p1rlv17912_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3eb66d3-0271-4842-8893-9a58f64e0279"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "737497c3-2c01-4ab2-a5db-da56979d37c2"}}}}, {"uuid": "35e16783-6c79-4cb2-8388-75a45ee8381c", "name": "27882881-f8f6-46ab-afa3-e2c94a85c378_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5290895920961123, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.36247808422876804, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "32cacb6c-cb9e-4d0b-bb0b-6ecc9421fcf1", "name": "2b39f0f8-eee4-4971-9ef8-b5929d463593", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "35e16783-6c79-4cb2-8388-75a45ee8381c"}}}]}, {"uuid": "ab4939ac-f9c6-4ce9-9625-94b0d4bcd5dc", "name": "load_p1rlv17912_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3eb66d3-0271-4842-8893-9a58f64e0279"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "32cacb6c-cb9e-4d0b-bb0b-6ecc9421fcf1"}}}}, {"uuid": "f121e983-b923-4500-a667-b0c458477d72", "name": "c4c3ef96-98c9-4de0-87a3-17dba1f39788_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.53872088738556, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0484090155056416, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "58b14df9-08c0-4c7d-8ffc-c69eb560f186", "name": "7454fbd0-0e55-4473-851a-edf12b088e6e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f121e983-b923-4500-a667-b0c458477d72"}}}]}, {"uuid": "72a62921-b6d9-4e38-948d-caef55f4832f", "name": "load_p1rlv17926_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2812bbb1-0bb0-499f-a394-0995784bb7bc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "58b14df9-08c0-4c7d-8ffc-c69eb560f186"}}}}, {"uuid": "c9d24559-cd5e-43ad-b30e-90aa7792fc53", "name": "467c2215-dde7-4a09-a503-571ccf8670c0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.53872088738556, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0484090155056416, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "873ca082-8d2a-4bbd-b64a-200399a7fa2e", "name": "ba080ed0-a082-40d1-870d-4cd6e9d28483", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9d24559-cd5e-43ad-b30e-90aa7792fc53"}}}]}, {"uuid": "dfa5b295-8bae-42f3-bac4-7cbd34dbd9b5", "name": "load_p1rlv17926_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2812bbb1-0bb0-499f-a394-0995784bb7bc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "873ca082-8d2a-4bbd-b64a-200399a7fa2e"}}}}, {"uuid": "a51df733-a1a0-44c8-b6da-4e51ae456dab", "name": "9727774c-93bc-41c4-8516-53ded346a01a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9243645178497548, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1029763549760416, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0b144409-29f3-4aae-973f-de0f15942722", "name": "f9d605d1-f989-4bbe-8d7d-3ee66c387489", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a51df733-a1a0-44c8-b6da-4e51ae456dab"}}}]}, {"uuid": "8dcabd59-b0bb-4578-9b9a-ddf3e05199bc", "name": "load_p1rlv17960_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "215a5974-e23b-46f0-bde9-f5ad16fdfaf8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0b144409-29f3-4aae-973f-de0f15942722"}}}}, {"uuid": "18d35654-eabd-48ad-b40e-e1a5f9d70b65", "name": "49f0a928-a1cd-4c63-b22d-ca6193302c0f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9243645178497548, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1029763549760416, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aed5f5f5-d1fc-428c-a25d-04a11d59a468", "name": "175c910f-8a28-4c5a-91dc-3c92d43f6a92", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "18d35654-eabd-48ad-b40e-e1a5f9d70b65"}}}]}, {"uuid": "7d94f70f-8b62-40ed-8e1a-3ef30f8baa32", "name": "load_p1rlv17960_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "215a5974-e23b-46f0-bde9-f5ad16fdfaf8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aed5f5f5-d1fc-428c-a25d-04a11d59a468"}}}}, {"uuid": "bef3716f-841e-42a0-b5c6-ad05d7d4b39e", "name": "40099928-ff6e-442e-926b-0313269e41dc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.498014754859445, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "38bf2759-9d5a-4191-81c9-7b6a88469a70", "name": "824f1227-95e5-416c-a14b-112fac6a710b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bef3716f-841e-42a0-b5c6-ad05d7d4b39e"}}}]}, {"uuid": "994236b6-d001-4192-9f84-405c6a284793", "name": "load_p1rlv17961_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2716887e-1701-4a78-805b-96da0781c7f8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "38bf2759-9d5a-4191-81c9-7b6a88469a70"}}}}, {"uuid": "e0606768-9b13-4f11-a250-4360c3e94b74", "name": "428da6b8-fa3a-4e61-9877-bb07755f3169_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.498014754859445, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dff768e5-d8c7-42b4-b30a-4e42f71261e9", "name": "9caf0ad2-af21-40a4-9e1a-a10322d5057f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e0606768-9b13-4f11-a250-4360c3e94b74"}}}]}, {"uuid": "eb5a0498-5956-4b87-9295-49e532a7dfe7", "name": "load_p1rlv17961_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2716887e-1701-4a78-805b-96da0781c7f8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dff768e5-d8c7-42b4-b30a-4e42f71261e9"}}}}, {"uuid": "9efb896d-0011-455d-b26f-581c13ab6ba1", "name": "e8f4e742-6ae7-41d1-aea6-4737074853a8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4651344294517608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7736313908316925, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1e24c802-acb4-4c9d-8e8b-82548499c030", "name": "20f50e06-ba44-4c08-a440-ac3d0c0ff194", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9efb896d-0011-455d-b26f-581c13ab6ba1"}}}]}, {"uuid": "522399a3-eb8a-4295-a203-4ad7992130ab", "name": "load_p1rlv17962_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec99daac-e0be-4ea1-ba4f-185d4943396d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1e24c802-acb4-4c9d-8e8b-82548499c030"}}}}, {"uuid": "929ca6ca-a3ce-42e9-a5e6-6a795631e22f", "name": "b3e41a9f-aa35-425f-ac89-4956de4a32e6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4651344294517608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7736313908316925, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a0ae656-44fb-451e-9ce3-335ca2aa43ad", "name": "5fd5411c-5965-4e7f-bef9-5bcb02bfb77e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "929ca6ca-a3ce-42e9-a5e6-6a795631e22f"}}}]}, {"uuid": "1cc045b5-a3a0-4869-a60f-a759e5eb16dd", "name": "load_p1rlv17962_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec99daac-e0be-4ea1-ba4f-185d4943396d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a0ae656-44fb-451e-9ce3-335ca2aa43ad"}}}}, {"uuid": "80c1306a-2395-499e-8d7b-a00ea5cbc1f5", "name": "36e9c8af-fb21-4fd7-ab9a-069eb5405324_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.107858967059457, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3651352875232526, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "575b6888-0bd4-41d2-b5c0-3b2efbd2bc27", "name": "4da172cc-66c4-41ea-a05f-8bc6c686b27a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "80c1306a-2395-499e-8d7b-a00ea5cbc1f5"}}}]}, {"uuid": "1a13d31f-dd8c-48db-9566-bb8555ff2eb6", "name": "load_p1rlv17969_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ccaf70a-35d8-4f16-b632-e282fe30b5ca"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "575b6888-0bd4-41d2-b5c0-3b2efbd2bc27"}}}}, {"uuid": "356eac4e-c227-4733-ad20-430ccd100a54", "name": "3bb91beb-def4-4ac9-837d-d19d44558d5b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.107858967059457, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3651352875232526, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4b44aed9-c5e4-43b8-850e-8d81021d55fa", "name": "c94f6aee-952d-4b57-8918-e23555512cf6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "356eac4e-c227-4733-ad20-430ccd100a54"}}}]}, {"uuid": "9bc6eff4-5e3a-4c95-9a8d-c503e9b2f022", "name": "load_p1rlv17969_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ccaf70a-35d8-4f16-b632-e282fe30b5ca"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4b44aed9-c5e4-43b8-850e-8d81021d55fa"}}}}, {"uuid": "7c8c52d7-c1da-4a84-9f8b-6da12b106261", "name": "e8394590-bd10-43e1-8be7-11875e03895a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8939358223380807, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6690937458929831, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "15f03cc3-4b5f-44ca-bf57-a3bfdbcaf20c", "name": "e884a5e6-d820-4ea9-88d5-f95975577ddd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7c8c52d7-c1da-4a84-9f8b-6da12b106261"}}}]}, {"uuid": "761d9060-9915-4396-823f-9d89270cc816", "name": "load_p1rlv17987_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0771ebfa-5eaf-4ae8-94f1-86de7a656f58"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "15f03cc3-4b5f-44ca-bf57-a3bfdbcaf20c"}}}}, {"uuid": "09143581-c632-4b97-9e2d-846f065ae568", "name": "c79622ae-1a19-4bd6-9a02-44a40c1271ed_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8939358223380807, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6690937458929831, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0770b80e-1ba4-4142-bbad-cb21fc5a7bf0", "name": "8e94e562-b508-49aa-9243-e8ee4ca25e68", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "09143581-c632-4b97-9e2d-846f065ae568"}}}]}, {"uuid": "55c4c05e-ffa0-4950-ab16-60ea16d44777", "name": "load_p1rlv17987_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0771ebfa-5eaf-4ae8-94f1-86de7a656f58"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0770b80e-1ba4-4142-bbad-cb21fc5a7bf0"}}}}, {"uuid": "7d268e87-7787-4271-8a16-4ca5cbd5b1ad", "name": "8f2eb056-9539-463c-bd7d-a24c464d0f5b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0404861968223509, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5307917165881004, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f336219e-e2ac-4bc3-a323-65e4d9edb635", "name": "c8fffeef-26c4-4fb7-a4e3-d188a91238ac", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7d268e87-7787-4271-8a16-4ca5cbd5b1ad"}}}]}, {"uuid": "c7e08a67-99af-4662-9700-745aab48ccab", "name": "load_p1rlv18044_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b40fac8c-a99b-4baa-940a-26565ba7d62b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f336219e-e2ac-4bc3-a323-65e4d9edb635"}}}}, {"uuid": "fd34ef56-f97c-4d4e-91c8-1b0e1d0d6fd7", "name": "7e460095-9f92-44b2-b8b5-9fab9d29e144_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0404861968223509, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5307917165881004, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "420f9a97-b7fc-4c97-b066-8df50a178869", "name": "329acef9-99ed-4b46-8b52-a131f586e947", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fd34ef56-f97c-4d4e-91c8-1b0e1d0d6fd7"}}}]}, {"uuid": "47e7ab04-3e9f-430e-be73-1584529a1096", "name": "load_p1rlv18044_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b40fac8c-a99b-4baa-940a-26565ba7d62b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "420f9a97-b7fc-4c97-b066-8df50a178869"}}}}, {"uuid": "5df3cb72-beb9-4ad3-b570-6d9cc60d23da", "name": "1b28d631-8654-4420-a891-23e721aae671_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.199673234956728, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.25859312667494616, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3adf9d10-fdb0-4c38-bf75-0d97ef0b4aaa", "name": "ec3d2672-b86c-4faf-9e3e-1457857bc427", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5df3cb72-beb9-4ad3-b570-6d9cc60d23da"}}}]}, {"uuid": "f12b8f76-6571-4c39-bfdd-40132252b81e", "name": "load_p1rlv18053_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4aeda1c7-41be-43c8-82e5-d7a347db86a8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3adf9d10-fdb0-4c38-bf75-0d97ef0b4aaa"}}}}, {"uuid": "79bf0340-ffdb-466c-9259-6dc5218d6227", "name": "4d063cd1-4fff-4f98-8177-f8adbb31c500_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.199673234956728, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.25859312667494616, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "60274c84-23f5-44ff-99e7-ad3b25f47512", "name": "3afce734-0a45-4eba-88ab-17b0dbd76aa7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "79bf0340-ffdb-466c-9259-6dc5218d6227"}}}]}, {"uuid": "4654b7ec-a734-477b-b98c-9cb10503571f", "name": "load_p1rlv18053_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4aeda1c7-41be-43c8-82e5-d7a347db86a8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "60274c84-23f5-44ff-99e7-ad3b25f47512"}}}}, {"uuid": "3e27d3ad-838f-4703-8e56-d400c5f8a3ce", "name": "3fcdee97-11a1-400c-b114-7c40df65b086_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7675749799903273, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6204429178040327, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "958bd145-fde9-484a-acfb-51e25fc3f9c8", "name": "ed7798d9-a2ac-41f6-b2e8-c2c2edac844e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3e27d3ad-838f-4703-8e56-d400c5f8a3ce"}}}]}, {"uuid": "88995c28-9ad6-4253-b4e5-abd41ca9e893", "name": "load_p1rlv18071_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86917829-123c-4fda-9809-dc61430a9fef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "958bd145-fde9-484a-acfb-51e25fc3f9c8"}}}}, {"uuid": "e771654a-ed9a-4ad0-b64e-2fbfa5239ffd", "name": "fa50f85a-044f-49a5-923f-a7bcddb40686_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7675749799903273, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6204429178040327, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b099b994-1dac-48a6-bafa-305c627fe7bd", "name": "34354eae-b6d8-4527-8a04-babf22ff2f34", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e771654a-ed9a-4ad0-b64e-2fbfa5239ffd"}}}]}, {"uuid": "1a472225-fbb8-44a1-b0ef-094c201ca96d", "name": "load_p1rlv18071_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86917829-123c-4fda-9809-dc61430a9fef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b099b994-1dac-48a6-bafa-305c627fe7bd"}}}}, {"uuid": "03075fc0-3dbe-4162-8d65-f42b924a9a81", "name": "cea04c29-238b-4c69-ab2d-8c7e7dd7b301_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2005170978204305, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8833048630127251, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cccf2bd5-fc9b-4b22-ad4f-6e60c8241b9b", "name": "6ca40b0d-06cc-469c-8da4-ce0f4ad063d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "03075fc0-3dbe-4162-8d65-f42b924a9a81"}}}]}, {"uuid": "28148e11-d3f7-4090-99b7-f2914a7771c7", "name": "load_p1rlv18100_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4863d28-4ee2-479d-accb-60b54f472fe7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cccf2bd5-fc9b-4b22-ad4f-6e60c8241b9b"}}}}, {"uuid": "d1cb8122-5757-430c-8855-0127ca1873f2", "name": "27c4cb99-9a24-411d-9960-24b11ac0eaec_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2005170978204305, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8833048630127251, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b05810b3-1268-45d7-9846-95cd0ad29b3c", "name": "5a0826ab-1ad9-460a-9b0c-cd7b6a386ea4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d1cb8122-5757-430c-8855-0127ca1873f2"}}}]}, {"uuid": "33841819-e3a2-4fec-a57f-b1864081f314", "name": "load_p1rlv18100_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4863d28-4ee2-479d-accb-60b54f472fe7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b05810b3-1268-45d7-9846-95cd0ad29b3c"}}}}, {"uuid": "8c72effc-f49a-4c58-ad55-22badf2f583d", "name": "2e352eb8-6201-4c37-ba59-10a9cb0eb2f3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2075389461119934, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3167249782629938, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "986789eb-fe6d-4ef7-840f-e5fcbf1e3bc0", "name": "bde6c827-9d2c-411b-a06d-3ba379010267", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8c72effc-f49a-4c58-ad55-22badf2f583d"}}}]}, {"uuid": "f2cfd818-8882-43e9-addd-e0ad44040a28", "name": "load_p1rlv18129_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "115a848f-f6f3-48f0-9f33-5a9103f1a892"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "986789eb-fe6d-4ef7-840f-e5fcbf1e3bc0"}}}}, {"uuid": "5a2ce607-31a7-40a7-8a80-162bb5787360", "name": "021e46a8-a5d4-4dc6-aa79-874afe956e42_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2075389461119934, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3167249782629938, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e9dab9c4-3f86-4dc0-bf0d-ba3fc0e13621", "name": "4569044e-ce09-49e1-9104-2878e36f1ec2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5a2ce607-31a7-40a7-8a80-162bb5787360"}}}]}, {"uuid": "4dbcd618-27f3-417a-9b1d-07e0894cd8f9", "name": "load_p1rlv18129_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "115a848f-f6f3-48f0-9f33-5a9103f1a892"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e9dab9c4-3f86-4dc0-bf0d-ba3fc0e13621"}}}}, {"uuid": "ed97d495-4878-4728-805d-f857a3a611ec", "name": "fc62f661-92ad-4639-88e3-9dca6a64180c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3268329182243828, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6606620655388332, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "12991d25-4c53-47d7-ab45-adc402c143d3", "name": "736cf412-ac15-4084-8de1-411be757913f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ed97d495-4878-4728-805d-f857a3a611ec"}}}]}, {"uuid": "f1da61cb-3884-4f89-b184-c3708d29eb39", "name": "load_p1rlv18166_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "431692e5-2917-41ea-aafc-96be180b7e27"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "12991d25-4c53-47d7-ab45-adc402c143d3"}}}}, {"uuid": "9d66f1fa-41a6-4581-ab8c-81e89618b04b", "name": "4cdb61f2-3a90-4f0c-ab4c-7a53207cf31a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3268329182243828, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6606620655388332, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d9c8f299-4954-40a4-a240-cd2adae70530", "name": "e14d0abd-926d-4b2e-83f2-6afa1fdc9b5b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9d66f1fa-41a6-4581-ab8c-81e89618b04b"}}}]}, {"uuid": "ebf7542b-7eda-4a54-ab7f-c9324bbf5e8d", "name": "load_p1rlv18166_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "431692e5-2917-41ea-aafc-96be180b7e27"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d9c8f299-4954-40a4-a240-cd2adae70530"}}}}, {"uuid": "ab46062b-f641-4da2-96c8-8c433018dd78", "name": "6972b329-1f10-4ef6-ad40-e76563e89199_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cc9487f5-2aab-43b3-992e-54f57e90d5c8", "name": "a56b133d-f339-48b0-b8e0-08351d898d96", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ab46062b-f641-4da2-96c8-8c433018dd78"}}}]}, {"uuid": "fb84b9e0-2dfe-44a9-a3f1-93c28e583a40", "name": "load_p1rlv18192_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c3e08a8-ea88-423d-b361-69509f7ab8fa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cc9487f5-2aab-43b3-992e-54f57e90d5c8"}}}}, {"uuid": "951d662a-0416-45f2-9997-c6e140565f83", "name": "45acbd5f-b7e8-46f1-a2e5-e99e1003350d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8434317b-50f4-4029-ab69-190b32871133", "name": "640917a0-312a-47c7-b00a-50b0d8a1dbf9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "951d662a-0416-45f2-9997-c6e140565f83"}}}]}, {"uuid": "2b1900a9-e3e5-4074-8d8d-25af0c96225a", "name": "load_p1rlv18192_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c3e08a8-ea88-423d-b361-69509f7ab8fa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8434317b-50f4-4029-ab69-190b32871133"}}}}, {"uuid": "b61f3f55-672b-4cad-aa77-43e4ce9bc1fc", "name": "75ffe928-d893-4390-b50f-05c00ef1ff76_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.948680292874151, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.769988963438003, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4882a0c1-919d-4da2-bc38-44888d427089", "name": "dc460813-a025-4a1b-9de4-26291cf0936d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b61f3f55-672b-4cad-aa77-43e4ce9bc1fc"}}}]}, {"uuid": "a07e8600-88ab-4422-91ff-ca68999aa185", "name": "load_p1rlv18197_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5e240e8-b27d-4181-a7ee-a004d3f5c58a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4882a0c1-919d-4da2-bc38-44888d427089"}}}}, {"uuid": "d0976f00-4aaa-4faa-9f7b-963cf6661a53", "name": "f4ed0f48-252c-4744-a8be-47521bb9e690_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.948680292874151, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.769988963438003, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9b834b4a-d6dd-458e-aa5e-c4b66586c32f", "name": "1d36f195-ab24-4b30-bc04-92e9ff7f7c9e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d0976f00-4aaa-4faa-9f7b-963cf6661a53"}}}]}, {"uuid": "e45885c7-2504-4309-9bf3-26a2709f647b", "name": "load_p1rlv18197_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5e240e8-b27d-4181-a7ee-a004d3f5c58a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9b834b4a-d6dd-458e-aa5e-c4b66586c32f"}}}}, {"uuid": "b44a5637-33ac-43e4-9b88-35bcc319c1f3", "name": "03c05035-fe62-4427-a676-da984a6bb1d9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1698158732703443, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8490689598373361, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7f7cd507-7c9d-44bc-8133-69917dbfc87c", "name": "ea4fc29e-6ff7-42a4-bb90-eab6be3af249", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b44a5637-33ac-43e4-9b88-35bcc319c1f3"}}}]}, {"uuid": "c4fbfa3b-3dc0-41e9-b442-03e16247c0a4", "name": "load_p1rlv18198_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a7cb078-af6c-4cd5-9aca-48f515f6e711"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7f7cd507-7c9d-44bc-8133-69917dbfc87c"}}}}, {"uuid": "e479fb2f-4e22-4c7a-b453-75f36c005814", "name": "50472ce7-6c1e-4b22-83fa-668d103c6d6f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1698158732703443, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8490689598373361, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f4b23009-956b-4690-aabc-ec574695bed0", "name": "69dad363-7f6e-43f7-ba5a-a1783a4cf1a8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e479fb2f-4e22-4c7a-b453-75f36c005814"}}}]}, {"uuid": "1a5ed19a-7d46-43e6-9691-6d3f55153c9f", "name": "load_p1rlv18198_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a7cb078-af6c-4cd5-9aca-48f515f6e711"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f4b23009-956b-4690-aabc-ec574695bed0"}}}}, {"uuid": "276ea94c-e3c1-4cc5-9859-3a79835d1732", "name": "7e861e6f-9889-4f20-a5da-ebcb502d6916_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1801024488747824, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6406661654566495, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "08b7b6d3-4881-4ee5-9ec6-4bfc51ec49ce", "name": "3f5ce7bc-bb23-445c-8e73-acaedd6d90a8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "276ea94c-e3c1-4cc5-9859-3a79835d1732"}}}]}, {"uuid": "299e6517-f4c9-4ce7-9581-76c2055f841a", "name": "load_p1rlv18960_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9178fdee-311f-40f5-bdd6-9b474a05247e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "08b7b6d3-4881-4ee5-9ec6-4bfc51ec49ce"}}}}, {"uuid": "72d93b5a-33ab-47bb-9adb-4ff1c9b299df", "name": "1696a9c2-4c7e-4554-aca7-0a06eb4fdd48_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1801024488747824, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6406661654566495, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "09b995d5-0033-485f-b28a-8760affaac32", "name": "464a37f8-2e6d-4d9c-bb83-37ddc44d0fab", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72d93b5a-33ab-47bb-9adb-4ff1c9b299df"}}}]}, {"uuid": "51ed28f6-fde9-4502-9bde-3b93db46f283", "name": "load_p1rlv18960_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9178fdee-311f-40f5-bdd6-9b474a05247e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "09b995d5-0033-485f-b28a-8760affaac32"}}}}, {"uuid": "899a49e6-7b69-4db2-8d09-8925b0ce3fb1", "name": "8053ebbb-7ea6-4faa-aa26-0b9f67c1feff_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2045141672666357, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3046267940472902, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "51a0facb-5b80-4fbb-9975-cb7581507496", "name": "91d20e8a-8b70-460f-b8fb-8ae972a78dc1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "899a49e6-7b69-4db2-8d09-8925b0ce3fb1"}}}]}, {"uuid": "2f8f440f-bdcc-448e-8f86-8b00ebb2acfc", "name": "load_p1rlv18967_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eef4f0cf-6e51-45e1-8b6e-84171f7cbef6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "51a0facb-5b80-4fbb-9975-cb7581507496"}}}}, {"uuid": "a725c8c0-7954-4257-9a35-a61da37a2e42", "name": "70fcedb9-cf7e-4485-9a0f-9e1e11138e2f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2045141672666357, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3046267940472902, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fe11e8fd-a436-4ca3-bd2b-cc95dca6b5fa", "name": "13bd4487-3d1d-4764-b85b-3eba9ec1eeef", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a725c8c0-7954-4257-9a35-a61da37a2e42"}}}]}, {"uuid": "9cc09d32-0935-4602-a270-cf01750eee4d", "name": "load_p1rlv18967_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eef4f0cf-6e51-45e1-8b6e-84171f7cbef6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fe11e8fd-a436-4ca3-bd2b-cc95dca6b5fa"}}}}, {"uuid": "1bc226e4-d825-48c6-b833-fe32cf0ae345", "name": "177bb8d7-148a-41b3-b2de-a89663e90700_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1222862909492073, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34523553920221683, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "125c1e25-a0ec-48cd-8e28-e7715a931e54", "name": "e722f372-88ba-4e37-8b0a-bd6dc16ffd8b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1bc226e4-d825-48c6-b833-fe32cf0ae345"}}}]}, {"uuid": "2f9a01e1-3bf0-4357-891e-89f0f5382d4b", "name": "load_p1rlv19146_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0bb184ad-cb26-4317-8c40-f2c8a9f80dab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "125c1e25-a0ec-48cd-8e28-e7715a931e54"}}}}, {"uuid": "d34e1d78-8d7c-417c-8892-0c55830d30ab", "name": "ff88758b-f910-4a31-8511-29aa0ed51445_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1222862909492073, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34523553920221683, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1ece6b38-82a3-43f4-84c9-09f1840cdf2b", "name": "a65f33d6-bdcc-4356-a949-430509372f0f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d34e1d78-8d7c-417c-8892-0c55830d30ab"}}}]}, {"uuid": "d93487e0-e966-46e0-8d01-1def495b974d", "name": "load_p1rlv19146_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0bb184ad-cb26-4317-8c40-f2c8a9f80dab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1ece6b38-82a3-43f4-84c9-09f1840cdf2b"}}}}, {"uuid": "69f7dbef-382f-4102-a948-57f2c415c946", "name": "a189b0be-1b52-4fcf-a047-5b79aafa0cb8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4868228207229564, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16976956391895093, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d130eab6-4e26-4eef-a078-d7c0b36a6ffc", "name": "90529770-274c-4c96-bb3b-977a5634b8af", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "69f7dbef-382f-4102-a948-57f2c415c946"}}}]}, {"uuid": "6e5c4f0f-df78-4714-9ce1-7d7261bf01ac", "name": "load_p1rlv19147_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "546433b3-d70e-49ed-9037-ec88adda79b9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d130eab6-4e26-4eef-a078-d7c0b36a6ffc"}}}}, {"uuid": "0a53069c-3064-4f06-872d-870fd265d2c3", "name": "6b8cac3e-b265-423f-8f4f-f24c760d8254_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4868228207229564, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16976956391895093, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "36dc5985-18ba-4e5e-9854-e0c0d806f1f2", "name": "487d7df3-d4f2-4ca3-b2f5-ddc7e6da5c1c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0a53069c-3064-4f06-872d-870fd265d2c3"}}}]}, {"uuid": "f6467e30-51e9-4a90-940c-a4135378cf12", "name": "load_p1rlv19147_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "546433b3-d70e-49ed-9037-ec88adda79b9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "36dc5985-18ba-4e5e-9854-e0c0d806f1f2"}}}}, {"uuid": "e0a27af4-c819-4cc9-9bec-a802754241a8", "name": "61c65a95-d6be-490c-865f-253fc9479b67_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "11b78b7d-430d-4a8d-bef5-0b834f29a3da", "name": "5165893a-7e75-4e7b-bb10-423a322366b4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e0a27af4-c819-4cc9-9bec-a802754241a8"}}}]}, {"uuid": "b4ee36f5-ff72-4a5a-9ce9-8298c7940304", "name": "load_p1rlv19149_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67a4600d-65c3-40d7-ad28-e8e37ff77dcb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "11b78b7d-430d-4a8d-bef5-0b834f29a3da"}}}}, {"uuid": "b126c6f7-d987-4d64-9271-4040e5e45fb2", "name": "411a8146-f899-45ca-9bf0-aab8e89c51e5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1deb3031-dd5d-4979-9be3-b3d7671c2f97", "name": "99cfbb7d-055c-4999-a3f9-841bc2001a22", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b126c6f7-d987-4d64-9271-4040e5e45fb2"}}}]}, {"uuid": "f7ecb440-0f55-4077-972a-53257e3a5828", "name": "load_p1rlv19149_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67a4600d-65c3-40d7-ad28-e8e37ff77dcb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1deb3031-dd5d-4979-9be3-b3d7671c2f97"}}}}, {"uuid": "2006ec6b-bb56-40ed-8a9f-8176087493fb", "name": "c814eae1-c780-4d8c-8f56-b953a77c46d9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9f955821-e89b-4b40-b4a1-6af5dd0b3574", "name": "8bc15210-bb12-457c-8ea0-0edd3dda432d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2006ec6b-bb56-40ed-8a9f-8176087493fb"}}}]}, {"uuid": "447a6f1f-7647-4dcf-9712-01fbb936a123", "name": "load_p1rlv19151_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e396aca-4116-40a0-8f17-bcd41f709ea5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9f955821-e89b-4b40-b4a1-6af5dd0b3574"}}}}, {"uuid": "c4fd19b7-b22f-46e5-b563-0298fb65e63c", "name": "ad996323-23ba-4d5d-b88c-159e5e2cbaaf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c137e1f1-bdbb-49ff-8f40-580b7e0f4224", "name": "ec44ced7-7c3c-4fde-b7fa-6b14d50146c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c4fd19b7-b22f-46e5-b563-0298fb65e63c"}}}]}, {"uuid": "c32a760d-f772-45ff-b58c-786f29590e79", "name": "load_p1rlv19151_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e396aca-4116-40a0-8f17-bcd41f709ea5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c137e1f1-bdbb-49ff-8f40-580b7e0f4224"}}}}, {"uuid": "c979f935-316d-4b43-8d51-0fae19c3ce1f", "name": "fa22fc25-8a81-4d5e-af8a-9ee320db2b53_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "99e06090-15dd-44ff-9d44-643acab3c309", "name": "f015c1fc-bc74-4fcb-a5c5-4c00e9b6e1a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c979f935-316d-4b43-8d51-0fae19c3ce1f"}}}]}, {"uuid": "67d5f06f-741f-4d64-8663-e91765b579ce", "name": "load_p1rlv19156_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7538ab85-10b4-4f60-98f8-179e954173b0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "99e06090-15dd-44ff-9d44-643acab3c309"}}}}, {"uuid": "63861aec-1ad6-4dff-a6b7-8e477408f934", "name": "266481a1-df1e-48ee-ab0c-e02cc76fe11c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5e21c6ee-1022-4216-8086-614971d8d0dc", "name": "bc1f8952-aa82-438a-b2de-7e231781adc7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "63861aec-1ad6-4dff-a6b7-8e477408f934"}}}]}, {"uuid": "9eccf85d-4195-48ef-b3e4-2066df60f2ca", "name": "load_p1rlv19156_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7538ab85-10b4-4f60-98f8-179e954173b0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5e21c6ee-1022-4216-8086-614971d8d0dc"}}}}, {"uuid": "ab78db94-1f0e-4dd7-83d1-9c218fb6c801", "name": "a4afcba3-8368-4025-a240-a48948785ede_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "03f0b66f-8782-437d-893c-4ab306535a7e", "name": "fd9b05bb-cd06-495e-ad6b-02b803e6ef0a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ab78db94-1f0e-4dd7-83d1-9c218fb6c801"}}}]}, {"uuid": "fb7b6520-f031-46e5-ab58-5a32c3720f76", "name": "load_p1rlv19157_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cf28b5d-d8d4-4883-a396-2d1ad9b70564"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "03f0b66f-8782-437d-893c-4ab306535a7e"}}}}, {"uuid": "4aec0a3d-5ed1-4d04-872b-4ea2c9a0270f", "name": "2b8246dc-5e8d-4877-b179-32172f58dbeb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "41a0cbe4-e162-4b07-8626-a429f97eb724", "name": "616828e3-a43b-4bd1-8729-bfc0edf8fea0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4aec0a3d-5ed1-4d04-872b-4ea2c9a0270f"}}}]}, {"uuid": "dfd1c368-60c2-4c49-a3d6-658df1829401", "name": "load_p1rlv19157_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cf28b5d-d8d4-4883-a396-2d1ad9b70564"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "41a0cbe4-e162-4b07-8626-a429f97eb724"}}}}, {"uuid": "656bb808-01e5-498d-b7e6-9d46d58c4339", "name": "e40be9cf-19b0-49f8-91cf-e7ed028086cb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cfb03cdd-df7b-4b87-835c-c55f81af6284", "name": "4b6fcb01-dac6-49ef-86a5-0aa8362e52c5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "656bb808-01e5-498d-b7e6-9d46d58c4339"}}}]}, {"uuid": "8b847b39-7e24-4032-b73b-2d85750c95c6", "name": "load_p1rlv19160_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7c1d210-ee87-46c5-b408-ad221cbeed04"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cfb03cdd-df7b-4b87-835c-c55f81af6284"}}}}, {"uuid": "204671b2-3428-47fe-846a-7027d0e70063", "name": "af954102-ced1-4ef2-aa4d-f783f34441d0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d77f185c-0a07-499e-94e4-504cda314ca5", "name": "355cf035-3998-4d46-9cef-82b52ea8b04f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "204671b2-3428-47fe-846a-7027d0e70063"}}}]}, {"uuid": "56a631ee-ab12-4070-82c8-c6afb5a609eb", "name": "load_p1rlv19160_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7c1d210-ee87-46c5-b408-ad221cbeed04"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d77f185c-0a07-499e-94e4-504cda314ca5"}}}}, {"uuid": "1257114c-fea5-441e-93ad-1e4d27afac16", "name": "5316039a-415e-4595-b908-92332fae7858_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c9e8216b-acd6-40a8-900a-1997fd54b543", "name": "a8fd5c09-0540-4cf1-96f7-2ccc4453783f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1257114c-fea5-441e-93ad-1e4d27afac16"}}}]}, {"uuid": "5e1657e0-b2a4-46b2-9af1-b71e3627f267", "name": "load_p1rlv19161_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16df6b90-d049-4160-b148-b888e03acb82"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c9e8216b-acd6-40a8-900a-1997fd54b543"}}}}, {"uuid": "29918bf7-fa41-4fc0-8435-78a1b354e19e", "name": "1dfbdde7-c939-48ca-ac88-d954a09977c3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8faaf976-ea71-4910-9243-aee1cb5d3875", "name": "90456313-14d1-4cfb-a466-8c19ad4da216", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "29918bf7-fa41-4fc0-8435-78a1b354e19e"}}}]}, {"uuid": "d570bd79-b4de-4cb4-b574-33abb71b1d14", "name": "load_p1rlv19161_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16df6b90-d049-4160-b148-b888e03acb82"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8faaf976-ea71-4910-9243-aee1cb5d3875"}}}}, {"uuid": "ba2ff638-568b-4237-b84f-6b8c4a91bc05", "name": "4cccfcec-862f-4664-bc65-7422e770750e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7930e8d4-bccc-4cf3-ae0f-3a50b581908a", "name": "b97340dc-d707-4767-8f8a-4206a3059695", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ba2ff638-568b-4237-b84f-6b8c4a91bc05"}}}]}, {"uuid": "4dfa51cb-050b-4616-880a-0ee67149a094", "name": "load_p1rlv19163_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fed6fcd4-3c97-4f62-a1a7-0b66394218e1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7930e8d4-bccc-4cf3-ae0f-3a50b581908a"}}}}, {"uuid": "b8d6d56e-9c72-4836-a2df-3cfa8013d452", "name": "7c3bf019-abfc-4bf4-8cf1-e4ee76528b6e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "78416a8d-5298-4100-90be-2e4fbc91d751", "name": "113e1321-cf95-47fb-9d92-56087fa014ad", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b8d6d56e-9c72-4836-a2df-3cfa8013d452"}}}]}, {"uuid": "f3f19601-292b-41de-af2e-8f3b1c6b0ae1", "name": "load_p1rlv19163_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fed6fcd4-3c97-4f62-a1a7-0b66394218e1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "78416a8d-5298-4100-90be-2e4fbc91d751"}}}}, {"uuid": "26aaa96b-786e-465c-a2d1-c8894affa276", "name": "de992046-31fd-456e-98b2-a83d9c206b75_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3913635530264314, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9282144314028667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aba50749-2a23-4445-9c0c-330d4aa4cf87", "name": "de992046-31fd-456e-98b2-a83d9c206b75_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3913635530264314, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9282144314028667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "717e806b-fad7-4a1d-916d-8b9115a4d843", "name": "de992046-31fd-456e-98b2-a83d9c206b75_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3913635530264314, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9282144314028667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b979ccd5-2f40-4746-a988-7df3e6b51ee6", "name": "c19c01a7-bb70-4fbf-a2ef-a87e599a4cc5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "26aaa96b-786e-465c-a2d1-c8894affa276"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aba50749-2a23-4445-9c0c-330d4aa4cf87"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "717e806b-fad7-4a1d-916d-8b9115a4d843"}}}]}, {"uuid": "3d93ef47-7f16-49ac-9061-3becf93bfb2e", "name": "load_p1rlv19164", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a02024b5-aa74-4e07-b043-a7a0e8b3e816"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b979ccd5-2f40-4746-a988-7df3e6b51ee6"}}}}, {"uuid": "44176e23-55fa-417c-9129-d715bc9d37e0", "name": "59d63d88-9fc3-472f-8ae1-7306b898b5b5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ff428f8c-2c3a-46ad-bb5b-4f6b3daa897a", "name": "793c4ce9-ef93-447c-969f-d8e370b4e3dc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "44176e23-55fa-417c-9129-d715bc9d37e0"}}}]}, {"uuid": "c19138fe-01ee-49cb-a8d6-b4871fe9a83d", "name": "load_p1rlv19165_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ebd10471-ab4c-4cb7-a822-a83ef20e9854"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ff428f8c-2c3a-46ad-bb5b-4f6b3daa897a"}}}}, {"uuid": "bd2d7e35-1845-408c-b298-02efde1b9cc8", "name": "30aadc1d-05e6-4d31-8f9e-392ba2a57f56_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5c200c50-9ade-4276-ac85-c37b94497797", "name": "4fe8aa86-072e-40d4-8c13-0a754e43967c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bd2d7e35-1845-408c-b298-02efde1b9cc8"}}}]}, {"uuid": "40f5f2ab-ba0c-40cb-bebf-3a82bfd0403b", "name": "load_p1rlv19165_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ebd10471-ab4c-4cb7-a822-a83ef20e9854"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5c200c50-9ade-4276-ac85-c37b94497797"}}}}, {"uuid": "db3a33cb-eb5f-4d19-8040-6ec5f2a248af", "name": "a0625715-56f8-4fdf-b453-3d7c15955b12_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c91b903a-179b-4b9c-8a91-ca04a45d4c0e", "name": "81bc24f8-de82-433f-8707-28c12fd0084a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "db3a33cb-eb5f-4d19-8040-6ec5f2a248af"}}}]}, {"uuid": "39bbf73a-53c6-4b2b-913c-1c0af0433c80", "name": "load_p1rlv19166_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "994f6392-f4e5-4ff8-9eeb-5849cd035912"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c91b903a-179b-4b9c-8a91-ca04a45d4c0e"}}}}, {"uuid": "8d2ed1ec-5a98-4037-90f6-92b438806eed", "name": "1094c4fe-7f5e-4bc1-a61c-0c9559c421da_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f285ff05-ecb6-4188-8db3-8a067e42b5ee", "name": "18649bc0-1baa-4dee-ab9d-f81face75a14", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8d2ed1ec-5a98-4037-90f6-92b438806eed"}}}]}, {"uuid": "07192b48-5d44-4d05-a633-d35c26bff647", "name": "load_p1rlv19166_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "994f6392-f4e5-4ff8-9eeb-5849cd035912"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f285ff05-ecb6-4188-8db3-8a067e42b5ee"}}}}, {"uuid": "51a86754-b9fd-4736-924c-c05f7f8f24cf", "name": "e0397dfc-2399-4620-a56c-99c8d416d2bc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6733980323267108, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22626974414284334, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50c4c48d-222e-4c54-8b4a-f763bdd5b7ce", "name": "44939ef2-1366-47f1-8979-9355dc7e84ee", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "51a86754-b9fd-4736-924c-c05f7f8f24cf"}}}]}, {"uuid": "e04e6f75-8d46-4726-bc92-bc890f422c32", "name": "load_p1rlv19168_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f8c76ca-40ea-4f7d-8042-66edd484f065"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50c4c48d-222e-4c54-8b4a-f763bdd5b7ce"}}}}, {"uuid": "f3bb7e45-84ac-4e2e-8c6c-125d4bcc1ede", "name": "a8ea18d3-c0a0-4561-80db-be47d3e3b27a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6733980323267108, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22626974414284334, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4e293a52-1321-43e4-986f-ff0fca24cd10", "name": "ebfa6fc3-90e8-4825-b481-5a41ede38177", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f3bb7e45-84ac-4e2e-8c6c-125d4bcc1ede"}}}]}, {"uuid": "29924464-4e3b-4d6c-9dcd-7a76c3a12c3c", "name": "load_p1rlv19168_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f8c76ca-40ea-4f7d-8042-66edd484f065"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4e293a52-1321-43e4-986f-ff0fca24cd10"}}}}, {"uuid": "96ad5f29-86ea-420a-a9cd-cbe7ca2e48eb", "name": "7db4b8c9-b98e-45ba-8a81-e9ce5bd4bb30_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0288569450045768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2608148575838028, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "23503b5a-e59b-4bb1-99f8-1e372e32a039", "name": "62c2d498-c75f-447d-8219-db50186f09b6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "96ad5f29-86ea-420a-a9cd-cbe7ca2e48eb"}}}]}, {"uuid": "e7dff548-5064-438a-a413-9aff670679b5", "name": "load_p1rlv19169_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4e8183-9148-477e-aa1b-ff31a5324273"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "23503b5a-e59b-4bb1-99f8-1e372e32a039"}}}}, {"uuid": "7386bf6b-5ea9-40f9-81d4-65cc62638403", "name": "4b60ec54-5e0c-4c8f-b177-4f0bffa4eab6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0288569450045768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2608148575838028, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b3b308a3-95f6-4303-ba39-ab01f40fb440", "name": "0a6d326f-8727-46a0-ac05-12991b041c50", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7386bf6b-5ea9-40f9-81d4-65cc62638403"}}}]}, {"uuid": "95cd4e39-549f-4256-bf1b-88f6a43ef741", "name": "load_p1rlv19169_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4e8183-9148-477e-aa1b-ff31a5324273"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b3b308a3-95f6-4303-ba39-ab01f40fb440"}}}}, {"uuid": "3e51eee4-c9b9-48b9-a509-6f5d3e28c164", "name": "ccaac138-77af-4e48-916d-b215032ae845_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9179777962446224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3481400399277513, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f5d6c979-9438-4c19-8522-4d45c399fcb9", "name": "88fa76d0-d740-4eb3-8795-a964b43c92f7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3e51eee4-c9b9-48b9-a509-6f5d3e28c164"}}}]}, {"uuid": "3f6ce2c3-d243-479a-a3f8-620a114cebfe", "name": "load_p1rlv19171_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fffe26f7-c4cc-420e-ab17-754cb0d9e659"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f5d6c979-9438-4c19-8522-4d45c399fcb9"}}}}, {"uuid": "d6c1250f-f71d-4f1a-bb72-14dfd31baa8a", "name": "16f46533-7fb7-48d6-a498-b14c5792acee_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9179777962446224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3481400399277513, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6a2bd906-7f88-4096-9f94-b57562a4e999", "name": "1226bbba-e446-4d18-ba7f-61609911329c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d6c1250f-f71d-4f1a-bb72-14dfd31baa8a"}}}]}, {"uuid": "5b046daf-851a-4c1b-bf0d-1ec757448c4d", "name": "load_p1rlv19171_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fffe26f7-c4cc-420e-ab17-754cb0d9e659"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6a2bd906-7f88-4096-9f94-b57562a4e999"}}}}, {"uuid": "f5c47ead-457b-4112-ad8c-4800362713a6", "name": "f3fed72c-794e-4ccf-bc98-1ddfbcffbf3e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2767849318619047, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.48605417385422345, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f0954b2-7595-4880-a85c-16379689a5a3", "name": "1f0ab7cf-00b3-4787-82dd-921330051fe0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f5c47ead-457b-4112-ad8c-4800362713a6"}}}]}, {"uuid": "de37a26e-d354-4d16-9ee2-102d49f9e97c", "name": "load_p1rlv19173_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21fec301-b67c-4042-a074-caf406c7f0b5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f0954b2-7595-4880-a85c-16379689a5a3"}}}}, {"uuid": "2755ca43-8485-4ee8-9f11-17dfc565e8b4", "name": "bf502988-57ea-4c56-817e-faeb9c732a97_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2767849318619047, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.48605417385422345, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "56afcfe9-dd5a-47a8-a53d-ba1dbef8cef0", "name": "c11a0f4c-9a5b-42bf-815d-2910e39bb476", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2755ca43-8485-4ee8-9f11-17dfc565e8b4"}}}]}, {"uuid": "fa66facc-d041-44f5-865d-955b3f553535", "name": "load_p1rlv19173_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21fec301-b67c-4042-a074-caf406c7f0b5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "56afcfe9-dd5a-47a8-a53d-ba1dbef8cef0"}}}}, {"uuid": "a8ae73b7-6e03-45d9-88de-409827be9cba", "name": "c2bd9970-2177-4852-a67c-9100fdfe36c5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4675207102133878, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42773122049615037, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b13a61e3-6de6-4b4d-ac19-c5e0a0b750b2", "name": "a98c29a4-7501-485a-9244-e39748d5e127", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a8ae73b7-6e03-45d9-88de-409827be9cba"}}}]}, {"uuid": "a0c7ea11-2c63-436f-879b-8ec104b8b6af", "name": "load_p1rlv19174_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0fc7d43-4f82-4100-99bf-6e30e03e95ce"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b13a61e3-6de6-4b4d-ac19-c5e0a0b750b2"}}}}, {"uuid": "fce4b9b9-ef25-43db-b488-7c2ccd0c63ed", "name": "827cf8ba-b9b6-4746-bab5-e2cecc2e9125_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4675207102133878, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42773122049615037, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7a4cae4e-d607-441d-8748-6f41ba771bd7", "name": "7fb7b1de-b694-4253-aed5-7dfb0b2b674f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fce4b9b9-ef25-43db-b488-7c2ccd0c63ed"}}}]}, {"uuid": "f84efad9-2336-4892-ac50-8af41feac531", "name": "load_p1rlv19174_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0fc7d43-4f82-4100-99bf-6e30e03e95ce"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7a4cae4e-d607-441d-8748-6f41ba771bd7"}}}}, {"uuid": "e654623f-313c-4b11-9315-ba6f2ef0b77e", "name": "dc4c20ae-4a63-412e-810d-23b4fd6c1190_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4660310317378347, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6643122913958558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "04555b76-290e-4556-b6b5-aa452336de03", "name": "c47057d9-5386-48fb-b604-4f93f2f5d2e1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e654623f-313c-4b11-9315-ba6f2ef0b77e"}}}]}, {"uuid": "061d6c99-a938-4855-b40a-9ef3068c8ecb", "name": "load_p1rlv19183_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "89bde057-807b-415c-9135-267c6bf43c44"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "04555b76-290e-4556-b6b5-aa452336de03"}}}}, {"uuid": "d0c2da70-16d4-4628-b508-621ecdfeeed0", "name": "c4771986-d8bf-440d-9b02-89deba7df031_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4660310317378347, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6643122913958558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6df221e1-7eb3-418c-ae30-18231f96db2c", "name": "4d7441d4-a0b8-4f87-a28f-9cc6381503b8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d0c2da70-16d4-4628-b508-621ecdfeeed0"}}}]}, {"uuid": "8ac36c2a-9eb2-4707-94ab-d7fed5c8d220", "name": "load_p1rlv19183_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "89bde057-807b-415c-9135-267c6bf43c44"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6df221e1-7eb3-418c-ae30-18231f96db2c"}}}}, {"uuid": "b079212d-2bdf-4bca-ae52-116cbe4167c7", "name": "860c4415-3bb1-4dc0-8a44-3322d4fe5bf7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.515259426400046, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4440975656599118, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3d8f19ec-f5a5-40d6-a2dd-707046dd3177", "name": "3c640dd5-a945-4231-8a4f-1bff34e77eb3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b079212d-2bdf-4bca-ae52-116cbe4167c7"}}}]}, {"uuid": "b6de3fac-4d6b-4a52-a9e2-e974cac85e5d", "name": "load_p1rlv19184_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50750ddb-80db-4d5f-bc62-4bbfc600a7ef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3d8f19ec-f5a5-40d6-a2dd-707046dd3177"}}}}, {"uuid": "75f6a9a4-4da0-4ec3-84b7-005556956265", "name": "89105886-e868-4927-8559-64821a385e04_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.515259426400046, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4440975656599118, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "efc0f742-5b1f-43a0-b2d4-5573c1a4d140", "name": "6e84dfc1-a870-431a-a07e-760ec8df0377", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "75f6a9a4-4da0-4ec3-84b7-005556956265"}}}]}, {"uuid": "971cc166-3ac8-4edc-b2a2-3530ffcaff58", "name": "load_p1rlv19184_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50750ddb-80db-4d5f-bc62-4bbfc600a7ef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "efc0f742-5b1f-43a0-b2d4-5573c1a4d140"}}}}, {"uuid": "754642c3-e803-4f34-baff-f09e25515573", "name": "baa45f2f-c3a6-49db-858a-ebdf21e7d73f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4040789998842194, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4565305929598704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5a7516eb-2e14-471b-b1a5-80ff03ee3fa7", "name": "d751e070-701e-4082-850e-878f679e40fa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "754642c3-e803-4f34-baff-f09e25515573"}}}]}, {"uuid": "66f572e4-3523-4380-9a62-0e30fd1a5db1", "name": "load_p1rlv19188_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47e24942-486d-46f1-a40f-0da5c93c013a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5a7516eb-2e14-471b-b1a5-80ff03ee3fa7"}}}}, {"uuid": "dad37bec-9b09-4868-9885-d2bcb994668d", "name": "32b1c83a-d83e-49c3-a245-2eeb2851a00a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4040789998842194, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4565305929598704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8014c6ba-e17d-4245-a9f8-48da6e5f0bd4", "name": "c16b5c3a-cb3c-48ec-80a5-95cc90f22f7b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dad37bec-9b09-4868-9885-d2bcb994668d"}}}]}, {"uuid": "e438f8bd-9345-4a19-a5dd-8239ac819ea3", "name": "load_p1rlv19188_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47e24942-486d-46f1-a40f-0da5c93c013a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8014c6ba-e17d-4245-a9f8-48da6e5f0bd4"}}}}, {"uuid": "7a9d7dc7-316b-40fa-b29f-90498d17c758", "name": "26b13717-8147-43cd-b52a-6d4b427ecf93_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.600795001494098, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2809795860066686, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eecd4421-78a7-416b-a3a3-deaf14e94d32", "name": "8205e059-91bc-4214-a0aa-c7c79f3147f7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7a9d7dc7-316b-40fa-b29f-90498d17c758"}}}]}, {"uuid": "1098ee10-5a4e-4a3c-b15d-d74068a9626a", "name": "load_p1rlv19189_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5fecc64a-4783-4ecb-a0d0-7e60d1cf6184"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eecd4421-78a7-416b-a3a3-deaf14e94d32"}}}}, {"uuid": "b052e304-473c-4eb4-860a-9a0bc656d98c", "name": "5d5bbf5b-4aec-4c9d-8284-8b9c4382b100_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.600795001494098, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2809795860066686, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7b3d9326-cef3-4965-890b-b628e4d53fec", "name": "754cf4af-6527-48c8-95e7-26b2c749a595", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b052e304-473c-4eb4-860a-9a0bc656d98c"}}}]}, {"uuid": "7473f293-ed7f-4335-bafc-5a15171814ac", "name": "load_p1rlv19189_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5fecc64a-4783-4ecb-a0d0-7e60d1cf6184"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7b3d9326-cef3-4965-890b-b628e4d53fec"}}}}, {"uuid": "00b124f3-cc84-430f-97a4-73423875313a", "name": "ceee5312-17ae-4fbf-b3d8-9867944bd18c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0490448796184286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8093782533373945, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "afbf58b1-8dca-4241-b36b-51ca85dc011d", "name": "2a4fd228-46cf-41a5-9624-030a18ec5c56", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "00b124f3-cc84-430f-97a4-73423875313a"}}}]}, {"uuid": "7a57a2de-df82-4671-9dcd-3f69ee3acdfb", "name": "load_p1rlv19190_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4aee02d4-8663-455b-a197-55b6b1470895"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "afbf58b1-8dca-4241-b36b-51ca85dc011d"}}}}, {"uuid": "04f380b5-c1ee-4699-8ded-bef9e45c57bb", "name": "857dc4d5-e612-450a-a93b-fa84a87f8f28_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0490448796184286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8093782533373945, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "006b69f8-f94f-41c8-87f5-22b2ee2e8765", "name": "d9ddc10a-cf53-4859-9d95-35c61f4addc0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "04f380b5-c1ee-4699-8ded-bef9e45c57bb"}}}]}, {"uuid": "7f756e00-95e8-4749-99b7-6533fb0bc45e", "name": "load_p1rlv19190_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4aee02d4-8663-455b-a197-55b6b1470895"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "006b69f8-f94f-41c8-87f5-22b2ee2e8765"}}}}, {"uuid": "7ed29888-5e04-490f-aa78-e62dd67093f3", "name": "a040e458-a970-4c7d-9686-89d2fcbe69ff_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7073298240395912, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.27247283022117846, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a0042c48-29f7-4122-9d41-8e1b226a1fa2", "name": "684f1f72-1aed-481a-bd57-43848c78bb39", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7ed29888-5e04-490f-aa78-e62dd67093f3"}}}]}, {"uuid": "5a6858d9-dc19-4959-bfe2-02bb18b2bb2f", "name": "load_p1rlv19194_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7daa1d3-6249-447d-a260-65de5ec0a470"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a0042c48-29f7-4122-9d41-8e1b226a1fa2"}}}}, {"uuid": "f3072aaf-be87-40e4-84fc-c06c6ea3506e", "name": "a7671389-ac45-4876-be86-4ad168ed35a0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7073298240395912, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.27247283022117846, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ed4e9771-7f88-46a3-a65f-5a9bd2944670", "name": "14dcf3fc-3c25-4d56-801f-913d72d024fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f3072aaf-be87-40e4-84fc-c06c6ea3506e"}}}]}, {"uuid": "bfd4db25-0215-426a-b567-04a4ac298abd", "name": "load_p1rlv19194_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7daa1d3-6249-447d-a260-65de5ec0a470"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ed4e9771-7f88-46a3-a65f-5a9bd2944670"}}}}, {"uuid": "3e86aca5-6aab-4f92-ae50-2bddbb36e1be", "name": "af904d00-c1d6-47a9-8edc-0af7c25654b2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5757409771642927, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7652901499575055, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d9809f00-acc3-4d7e-9b89-1477725e87a3", "name": "e0954155-7e81-40da-9db5-b2d1b498ce7a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3e86aca5-6aab-4f92-ae50-2bddbb36e1be"}}}]}, {"uuid": "eac7a319-9e7b-4f16-ad17-ce684bc7550d", "name": "load_p1rlv19667_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33dcb037-4cc8-480f-aac4-bc95e54e165e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d9809f00-acc3-4d7e-9b89-1477725e87a3"}}}}, {"uuid": "ccde68f5-b039-4bda-ae4c-9efd64edbf23", "name": "b40bf064-50a2-4e66-a1e0-0d7e208df0bc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5757409771642927, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7652901499575055, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d5d225fe-1f02-44a7-9290-99e5d55a6faa", "name": "c8517da0-0aae-4d9e-80d3-b8b25f936384", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ccde68f5-b039-4bda-ae4c-9efd64edbf23"}}}]}, {"uuid": "159a267b-a341-462f-af3b-8d2fa2d7a9d3", "name": "load_p1rlv19667_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33dcb037-4cc8-480f-aac4-bc95e54e165e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d5d225fe-1f02-44a7-9290-99e5d55a6faa"}}}}, {"uuid": "ea589c8f-cc85-4486-a172-dcfb51a011cf", "name": "6ff93963-157c-49bf-808e-721b4befa146_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.539100612527363, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.549143952601146, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ae4c2fae-3337-426c-b97e-93002c961cff", "name": "f70c2f5e-b770-488a-ac4d-23d574d34886", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ea589c8f-cc85-4486-a172-dcfb51a011cf"}}}]}, {"uuid": "dd60ac8b-a84d-40ba-9706-2eefe88e3183", "name": "load_p1rlv19668_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6427f66-2e22-40bb-83f1-2a8b1be9191a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ae4c2fae-3337-426c-b97e-93002c961cff"}}}}, {"uuid": "ef8495a0-4d6b-4995-9400-667c6fe969bb", "name": "9f15c2b1-07cb-41d4-84c2-b17acd8dffbf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.539100612527363, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.549143952601146, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c6c85d9c-f0c9-47a9-9a63-ed573637a24e", "name": "c979cb7e-77c5-47f1-b96d-fba1ec56a04b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ef8495a0-4d6b-4995-9400-667c6fe969bb"}}}]}, {"uuid": "4e059a4d-2a38-4306-845c-491ec42a2875", "name": "load_p1rlv19668_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6427f66-2e22-40bb-83f1-2a8b1be9191a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c6c85d9c-f0c9-47a9-9a63-ed573637a24e"}}}}, {"uuid": "f27f007c-2e11-4bdb-bb7e-100621d0bc49", "name": "44437314-92d0-4a62-9834-4fb8eaae5d2e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4037437915385973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5086059213404144, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b949ff1c-0f56-4d40-a461-22cc4cdac93d", "name": "8bae368a-487c-4de4-831a-d8fc546f342b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f27f007c-2e11-4bdb-bb7e-100621d0bc49"}}}]}, {"uuid": "8a5023e4-c0f5-44a0-a855-3398bd2dc9c9", "name": "load_p1rlv19669_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96d3079a-02f1-4c89-ad75-fd0a438c9cf4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b949ff1c-0f56-4d40-a461-22cc4cdac93d"}}}}, {"uuid": "d33f15fc-edf5-4bfa-a3d5-74552ed68265", "name": "61b541aa-9206-4840-ac4f-706ef534c1f5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4037437915385973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5086059213404144, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "117008e9-c0bf-4cc9-b860-289a2d757b15", "name": "8a0f45ea-92a7-4798-8d8f-ebe97c55be71", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d33f15fc-edf5-4bfa-a3d5-74552ed68265"}}}]}, {"uuid": "a21aa7c8-8062-4e99-a92d-1883e14314dc", "name": "load_p1rlv19669_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96d3079a-02f1-4c89-ad75-fd0a438c9cf4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "117008e9-c0bf-4cc9-b860-289a2d757b15"}}}}, {"uuid": "2603ec16-0540-4eeb-a2cd-701568cc54c0", "name": "179e0570-a4a0-4b27-babd-3f4c9ccc0700_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.308477864741614, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307751830484037, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bb9e05e9-b83a-4c56-868c-c22d46686968", "name": "ccb173c5-314b-446f-99a3-56f5a6f88a2e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2603ec16-0540-4eeb-a2cd-701568cc54c0"}}}]}, {"uuid": "10d06a86-24d8-43c3-be81-9e7524c167b8", "name": "load_p1rlv19675_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0031ab1b-d82d-40a5-b41e-bc6f6cb53069"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bb9e05e9-b83a-4c56-868c-c22d46686968"}}}}, {"uuid": "19e75e2a-07c5-4b8d-9791-c5f455991a2b", "name": "eeea6a3d-a27e-466c-b070-2ecd8d446e1f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.308477864741614, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307751830484037, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d7ca90cb-332d-4801-bedc-06caa0a9d9b9", "name": "69c8d922-d412-4b91-aa6a-1c77f7b1828a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "19e75e2a-07c5-4b8d-9791-c5f455991a2b"}}}]}, {"uuid": "d2997514-1651-4b24-9fbe-70e223296d34", "name": "load_p1rlv19675_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0031ab1b-d82d-40a5-b41e-bc6f6cb53069"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d7ca90cb-332d-4801-bedc-06caa0a9d9b9"}}}}, {"uuid": "3a9b348e-e778-4211-801f-9e6f1d945b9c", "name": "9930f8d0-e7ac-478b-a9f3-6b79645baaaa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4359784649582454, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.14838741475370543, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f5ab5822-1abe-4c20-b73a-0de7d7ba03a1", "name": "ef801244-6147-4689-a91b-878c0eaf26d9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3a9b348e-e778-4211-801f-9e6f1d945b9c"}}}]}, {"uuid": "ad50bdea-72ac-428a-acdf-166a01d5d7af", "name": "load_p1rlv19681_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83afc678-d577-4ef1-afa2-8e3f915a158b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f5ab5822-1abe-4c20-b73a-0de7d7ba03a1"}}}}, {"uuid": "59538ed4-fede-470a-822f-3b8d98eb3227", "name": "29f77274-9da6-4ea5-a124-b6f948542cf6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4359784649582454, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.14838741475370543, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0338d20b-ad9a-42c7-8b29-7ed52185693a", "name": "4a81538b-7048-42c6-b044-9669b84e90c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "59538ed4-fede-470a-822f-3b8d98eb3227"}}}]}, {"uuid": "b3a4b610-473d-4d59-9f38-1d36ac630f13", "name": "load_p1rlv19681_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83afc678-d577-4ef1-afa2-8e3f915a158b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0338d20b-ad9a-42c7-8b29-7ed52185693a"}}}}, {"uuid": "d1d0c3a6-4a7f-400b-a363-43c849f9c524", "name": "66047564-508a-4cec-b8ce-63f7ef123416_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4849313480010438, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7277224910757479, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "77941e17-d559-4b1f-b3a3-600923300a63", "name": "3935ff4f-cb25-4218-b2e7-8cd01e2a9328", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d1d0c3a6-4a7f-400b-a363-43c849f9c524"}}}]}, {"uuid": "10735e5a-5755-40a0-8e82-1d583800ddcd", "name": "load_p1rlv19682_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "811acd48-b61c-4a42-b76e-f995961c450e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "77941e17-d559-4b1f-b3a3-600923300a63"}}}}, {"uuid": "fe7d7d58-2846-4202-8450-e78c57fe55f0", "name": "67b3f1c5-2afe-4529-a0f5-ef4b9c245518_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4849313480010438, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7277224910757479, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "42a267db-803a-4bc8-a40d-d8ab8ee7b199", "name": "7fc602c6-9be3-4295-b436-83f2fc0ea5e2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fe7d7d58-2846-4202-8450-e78c57fe55f0"}}}]}, {"uuid": "53946547-2e1c-4c77-a55f-c649d926f97d", "name": "load_p1rlv19682_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "811acd48-b61c-4a42-b76e-f995961c450e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "42a267db-803a-4bc8-a40d-d8ab8ee7b199"}}}}, {"uuid": "d26bc30f-0158-4c51-917f-c60ce491b3fb", "name": "b8d0cf34-a770-4338-910b-adc97ba3d421_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2440101223346245, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10648703060010346, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1acdbbdd-5dcb-4b9e-9a4e-5bc71457e53d", "name": "a127345d-9a3b-48db-bf79-acbad49eb2aa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d26bc30f-0158-4c51-917f-c60ce491b3fb"}}}]}, {"uuid": "1ed25cf3-552c-44cd-b511-1701113ba3c8", "name": "load_p1rlv19686_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47f5777d-2c8d-48c2-bf28-386f3f3dbac4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1acdbbdd-5dcb-4b9e-9a4e-5bc71457e53d"}}}}, {"uuid": "af93eee8-f9bb-442b-a583-01f70afd4be2", "name": "6d593d1f-33a6-427a-b162-895b1023099a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2440101223346245, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10648703060010346, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "65e22d17-96fc-4665-886e-7e790749b309", "name": "303f0c22-2214-43e0-8822-e0bf37a2d074", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "af93eee8-f9bb-442b-a583-01f70afd4be2"}}}]}, {"uuid": "edfb7a27-0781-491e-8b2c-05146ed035ea", "name": "load_p1rlv19686_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47f5777d-2c8d-48c2-bf28-386f3f3dbac4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "65e22d17-96fc-4665-886e-7e790749b309"}}}}, {"uuid": "8a3bd121-0a2f-44af-8082-f24496c7efe4", "name": "048758ca-e638-4bfd-8d21-93557dbc8592_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.895690985965537, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9400572249599172, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "80125096-6207-409a-b0d9-669647c2319a", "name": "08ab45e8-b3a6-4390-a198-d173f57dec21", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a3bd121-0a2f-44af-8082-f24496c7efe4"}}}]}, {"uuid": "5305c7c6-d109-4a09-b2a2-f92de08df8bd", "name": "load_p1rlv19689_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "578b5df8-1dd8-41d9-b6dc-db75db5b115e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "80125096-6207-409a-b0d9-669647c2319a"}}}}, {"uuid": "69ac157c-6e9f-4962-b7cd-69c3655c9828", "name": "bc38a9b4-53f4-432b-a1d0-61ccee37928b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.895690985965537, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9400572249599172, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "43567337-5bcb-4f0c-8318-114fb73d774a", "name": "b7bfa72b-5be3-4ee8-98c8-62cfb2e5ba89", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "69ac157c-6e9f-4962-b7cd-69c3655c9828"}}}]}, {"uuid": "54029791-40d2-46d2-b363-b156e77814c3", "name": "load_p1rlv19689_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "578b5df8-1dd8-41d9-b6dc-db75db5b115e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "43567337-5bcb-4f0c-8318-114fb73d774a"}}}}, {"uuid": "c165eb8f-b5a6-4e6d-9104-35e132a992cc", "name": "c3532b3a-9e3e-417c-9ee3-307cd4b961fd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.308477864741614, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307751830484037, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1b649937-0e7f-494f-b253-419d69e74bab", "name": "76d649ac-cd9e-4f5c-8296-c2ba742698b1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c165eb8f-b5a6-4e6d-9104-35e132a992cc"}}}]}, {"uuid": "c66fa230-0cb1-48ff-ae1e-b329cd193928", "name": "load_p1rlv19690_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2709a70-1a7d-454c-90fd-377e416a0071"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1b649937-0e7f-494f-b253-419d69e74bab"}}}}, {"uuid": "4e74008a-5710-4b3a-b8df-8f73b24776d4", "name": "0347b171-ddc6-480b-8f2e-881491975645_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.308477864741614, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307751830484037, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8b8100cd-4d06-4016-874c-663fb29a2a84", "name": "e0c941a5-31a2-43c6-8d2c-7bab3fe96d52", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4e74008a-5710-4b3a-b8df-8f73b24776d4"}}}]}, {"uuid": "f5b02566-069f-4c58-a0a6-5eed94d9e47c", "name": "load_p1rlv19690_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2709a70-1a7d-454c-90fd-377e416a0071"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8b8100cd-4d06-4016-874c-663fb29a2a84"}}}}, {"uuid": "77165c56-c89d-4ebb-ad57-9b1e28126383", "name": "48fa7aea-32e0-4c8a-bbd1-1cebf6f5d9b6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5901541038441702, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.07457634724192848, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fc34bb05-87f4-4799-a01d-3927f582bcd6", "name": "34f24218-15e1-4f5c-9d09-301a0c1f76cb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "77165c56-c89d-4ebb-ad57-9b1e28126383"}}}]}, {"uuid": "9b820f03-083c-4edf-81ea-27dfe2aee5e5", "name": "load_p1rlv19691_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "604cb559-0f18-4ef7-8bcd-a07a7e7f96d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fc34bb05-87f4-4799-a01d-3927f582bcd6"}}}}, {"uuid": "3a4a5f53-1e04-402a-a6db-3045fa896c82", "name": "788da8c3-0c69-4a0a-8924-972af172aebf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5901541038441702, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.07457634724192848, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "58a9b220-c202-49b7-be70-961245a29423", "name": "05b00e44-bc66-4e6e-a026-9cdc0e5901ac", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3a4a5f53-1e04-402a-a6db-3045fa896c82"}}}]}, {"uuid": "88111d81-0056-4c62-8fa1-ad8367b8b2d7", "name": "load_p1rlv19691_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "604cb559-0f18-4ef7-8bcd-a07a7e7f96d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "58a9b220-c202-49b7-be70-961245a29423"}}}}, {"uuid": "cf87f2b7-175d-4ce8-84c5-e47d6819cd32", "name": "f611a5d7-dea6-405a-9320-609bc39ca2c3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.424079283052672, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.088828085193726, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "28d0d815-3de0-490c-94ae-4c4fa92969da", "name": "f40f87e8-d79c-4aea-a77f-fe8f67002d74", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cf87f2b7-175d-4ce8-84c5-e47d6819cd32"}}}]}, {"uuid": "620421db-9084-49f1-afa1-15b5180d2e9d", "name": "load_p1rlv19692_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b10b272a-2efb-4e19-9921-d4081fb45778"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "28d0d815-3de0-490c-94ae-4c4fa92969da"}}}}, {"uuid": "6201eba7-27e1-4bfa-9236-6be455ae382f", "name": "874ea8ba-2e4a-4758-8910-ffb5aba63a6d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.424079283052672, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.088828085193726, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8fc451d1-1b3a-4027-b6e4-5ab4e353ac33", "name": "c428ca70-9ec6-42e4-9498-df2ce9a9ac01", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6201eba7-27e1-4bfa-9236-6be455ae382f"}}}]}, {"uuid": "89953e12-96e9-494d-a5bc-45969cf03417", "name": "load_p1rlv19692_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b10b272a-2efb-4e19-9921-d4081fb45778"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8fc451d1-1b3a-4027-b6e4-5ab4e353ac33"}}}}, {"uuid": "3e120d1d-e367-4433-8b5c-5cfa4c05bfc7", "name": "c623f11b-f702-4be1-b6b2-d417ae367f0e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.01164824929789, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.30321095330991316, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8e3290d6-521b-4a69-9aa7-a5478a53a9a7", "name": "54f4d3c8-6a3a-4744-a32c-5dacea40d4b8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3e120d1d-e367-4433-8b5c-5cfa4c05bfc7"}}}]}, {"uuid": "98a8d7ce-fa0d-4b53-b172-4c1b6aba6bf7", "name": "load_p1rlv19695_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35fe21a1-f817-426e-9e42-f1f33876dd7d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8e3290d6-521b-4a69-9aa7-a5478a53a9a7"}}}}, {"uuid": "eec4bf16-f1ed-4404-8554-8574940fe947", "name": "272ae202-08fa-4d80-839a-9a3080a1e95f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.01164824929789, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.30321095330991316, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7f95e30e-ea29-451d-87fb-c069d649283a", "name": "6493fce6-8465-4769-9eee-2221707dc58f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eec4bf16-f1ed-4404-8554-8574940fe947"}}}]}, {"uuid": "c20c99cb-c78e-4ae5-aa2e-2accbced38cf", "name": "load_p1rlv19695_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35fe21a1-f817-426e-9e42-f1f33876dd7d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7f95e30e-ea29-451d-87fb-c069d649283a"}}}}, {"uuid": "f145327e-2162-42b6-8a11-26b2bfde7600", "name": "a9857ff6-34b2-4ec8-843b-b4f93dab0a28_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.445994317964332, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8597073331859654, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0c3432cf-d00e-420c-ad29-b45eceacc58a", "name": "632e3014-86c5-401b-9e6a-ea8235b3a564", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f145327e-2162-42b6-8a11-26b2bfde7600"}}}]}, {"uuid": "e7c985a2-dd3e-4ea6-a120-8c6d8e866d63", "name": "load_p1rlv19698_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14b1ab4e-b22d-4a98-8131-fc72c923c735"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0c3432cf-d00e-420c-ad29-b45eceacc58a"}}}}, {"uuid": "b8c806b8-d2d3-4b6e-9b57-3cb8b968f85c", "name": "d51b1bd3-7852-492c-a51e-5ca1e90b38b4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.445994317964332, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8597073331859654, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6354f900-88a1-49f8-bd70-306ee4e16e14", "name": "0a0e1126-55ca-455d-8658-67827e307025", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b8c806b8-d2d3-4b6e-9b57-3cb8b968f85c"}}}]}, {"uuid": "a9fe8784-2888-44a7-afa3-24d828418cda", "name": "load_p1rlv19698_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14b1ab4e-b22d-4a98-8131-fc72c923c735"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6354f900-88a1-49f8-bd70-306ee4e16e14"}}}}, {"uuid": "f317c62a-0a34-4e0b-bffb-508a05b0080c", "name": "162071be-39d3-423a-9165-bfd64e018cd2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4663769608466568, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5502546109327153, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fc82c7e2-b64e-46ce-ac11-0609a93d3242", "name": "ca1e6878-747f-48b5-aafb-2e7baf793657", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f317c62a-0a34-4e0b-bffb-508a05b0080c"}}}]}, {"uuid": "888dbe4f-cd30-4381-bcec-a643f2c74829", "name": "load_p1rlv19699_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48654a82-ac11-4542-94ec-8f731138e1a8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fc82c7e2-b64e-46ce-ac11-0609a93d3242"}}}}, {"uuid": "462bcf4f-c7e0-42f4-b852-f1a30a0b2a49", "name": "678cde70-2782-44ef-94fa-676fc2adb482_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4663769608466568, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5502546109327153, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cf65c499-b81c-4756-b5fc-cb82c815f025", "name": "f57da8ee-9669-44e5-b79d-404a52a01290", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "462bcf4f-c7e0-42f4-b852-f1a30a0b2a49"}}}]}, {"uuid": "fbe73a3c-692a-4ac9-851d-923425420048", "name": "load_p1rlv19699_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48654a82-ac11-4542-94ec-8f731138e1a8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cf65c499-b81c-4756-b5fc-cb82c815f025"}}}}, {"uuid": "179a4141-de77-4c08-a44c-94bc38111e71", "name": "b8edef17-753c-4640-ac88-234b59bd56b6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.331677082668279, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10958157805626084, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "de6c7d43-35c0-417e-9fbd-95f4c1c8135d", "name": "757edf94-1466-40b6-96a7-ca913b133456", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "179a4141-de77-4c08-a44c-94bc38111e71"}}}]}, {"uuid": "4e5e96cb-f1a5-43fa-93cb-23867576491d", "name": "load_p1rlv19701_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b5d936f-b3e0-408e-aabd-d3ebb7b869b0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "de6c7d43-35c0-417e-9fbd-95f4c1c8135d"}}}}, {"uuid": "240b3ec9-bc79-4c17-a8ee-8a8a425aa703", "name": "a68403b6-c7d7-45d0-83a6-4cfb97dc1f03_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.331677082668279, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10958157805626084, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c529a6f8-27f2-45db-aa1e-b8735c436127", "name": "928f825a-6ba2-4c81-a7c3-16861b88d2fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "240b3ec9-bc79-4c17-a8ee-8a8a425aa703"}}}]}, {"uuid": "51fa4197-1ba0-4eb2-b976-cb70045c9dfc", "name": "load_p1rlv19701_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b5d936f-b3e0-408e-aabd-d3ebb7b869b0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c529a6f8-27f2-45db-aa1e-b8735c436127"}}}}, {"uuid": "156a0ac9-458f-4c46-a04e-17ab1c6a23b4", "name": "932c9135-e467-4500-aee5-e3c7f125befa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 10.082274628538993, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.081607403669262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "326677db-6a41-4e8b-980e-90d10d1b78e7", "name": "60006b6a-3bcf-4371-a609-3fc2fb90e38a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "156a0ac9-458f-4c46-a04e-17ab1c6a23b4"}}}]}, {"uuid": "f9d708c9-eff7-4751-bcfa-65f0229b06c6", "name": "load_p1rlv19702_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37f72c85-61f7-4a42-94b0-6a627195458c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "326677db-6a41-4e8b-980e-90d10d1b78e7"}}}}, {"uuid": "42ff104e-d487-488b-8198-ae0df3abe8a3", "name": "6210e0b1-6210-4b7e-ab87-a9bed2bc7dc2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 10.082274628538993, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.081607403669262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0bdc9d7e-fba8-49d4-9a57-658e2eb6cdd9", "name": "c227d2e3-0c90-4d1c-8c71-cc21d84664af", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "42ff104e-d487-488b-8198-ae0df3abe8a3"}}}]}, {"uuid": "6c4ddb26-7f82-4578-95a1-80c652ba322a", "name": "load_p1rlv19702_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37f72c85-61f7-4a42-94b0-6a627195458c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0bdc9d7e-fba8-49d4-9a57-658e2eb6cdd9"}}}}, {"uuid": "3184dfb6-fe85-425b-8a2c-c8fcabee3cd9", "name": "434fc340-de1b-4a82-8747-2248052d2c85_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3786182488338723, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5359363058124609, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b2355f90-4b19-4f76-80f4-adbeb95f2861", "name": "e61cb651-ad75-433a-9e9b-e9b2fda0facc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3184dfb6-fe85-425b-8a2c-c8fcabee3cd9"}}}]}, {"uuid": "dd16986e-9178-4da5-94b5-abcd4a1cc80e", "name": "load_p1rlv20064_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aaea76fa-797e-46c5-a70f-a973977db841"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b2355f90-4b19-4f76-80f4-adbeb95f2861"}}}}, {"uuid": "3feb125e-0d30-4fa3-82b5-0a90a68f4f14", "name": "875ba8f6-e4f4-4981-89ed-f27d39ef2d03_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3786182488338723, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5359363058124609, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "faf06bc4-7f26-4a7b-981a-687b60237334", "name": "d62f7ca0-6d08-4cd6-8386-a2ad5803c0a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3feb125e-0d30-4fa3-82b5-0a90a68f4f14"}}}]}, {"uuid": "57d2795d-d45e-4749-ac18-4571bed715e7", "name": "load_p1rlv20064_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aaea76fa-797e-46c5-a70f-a973977db841"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "faf06bc4-7f26-4a7b-981a-687b60237334"}}}}, {"uuid": "697fca7f-f900-4399-9c9d-b7205ca2b896", "name": "1d1f1f6b-373d-428a-802b-e75f3af3d344_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9024769844937937, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4778358547008617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c89f6f9b-6be1-4081-a28f-ed71a35d83d4", "name": "81dd230b-be00-4e12-8599-9ff89e8d8aeb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "697fca7f-f900-4399-9c9d-b7205ca2b896"}}}]}, {"uuid": "f79d6824-33e0-4ddd-951e-c7a5dac2dc56", "name": "load_p1rlv20065_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea48ffa1-bdb3-4c15-96c9-ff7d7f34824f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c89f6f9b-6be1-4081-a28f-ed71a35d83d4"}}}}, {"uuid": "ad82f3f6-4fb0-493e-93e1-77619dfd382d", "name": "3e63e9a2-9263-49c9-8ce1-3b47b443769f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9024769844937937, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4778358547008617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "73056679-3214-4d0f-83d7-ea183b641d86", "name": "bbc86f6c-acca-45bc-b5c8-5c8e39c6bde2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ad82f3f6-4fb0-493e-93e1-77619dfd382d"}}}]}, {"uuid": "3fa11059-f23c-4332-afc5-f519c6bc4dfa", "name": "load_p1rlv20065_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea48ffa1-bdb3-4c15-96c9-ff7d7f34824f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "73056679-3214-4d0f-83d7-ea183b641d86"}}}}, {"uuid": "82613dda-2b0e-4576-ae18-3bae3f4b0bc1", "name": "12d6d0c1-1c78-4fba-80b4-98cd493320f6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9149869461814677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5767582022429075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "785fa984-c159-4e43-95ba-4838988535f5", "name": "33e33e39-b784-4951-a35e-45fe11e0de3a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "82613dda-2b0e-4576-ae18-3bae3f4b0bc1"}}}]}, {"uuid": "c8b6dbe3-fffb-47f6-b40d-5d02da5b6d2b", "name": "load_p1rlv20066_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f450eeb4-3d87-4ae5-a6d6-958d7efd2712"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "785fa984-c159-4e43-95ba-4838988535f5"}}}}, {"uuid": "173dc49f-cf27-46a6-9b3c-0c661da60210", "name": "5bc0a30a-237a-4fd5-8bc2-85472c196b45_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9149869461814677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5767582022429075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f540a76d-b5bb-431a-b2f2-50d5e78ab247", "name": "378ad036-0bbd-4070-b526-a3133b72d989", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "173dc49f-cf27-46a6-9b3c-0c661da60210"}}}]}, {"uuid": "db1b57aa-7de9-440d-883d-9651cdeae0a4", "name": "load_p1rlv20066_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f450eeb4-3d87-4ae5-a6d6-958d7efd2712"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f540a76d-b5bb-431a-b2f2-50d5e78ab247"}}}}, {"uuid": "2e8cf59c-6701-435e-8544-46ba106c78c7", "name": "8033911c-8184-4264-a0e0-42e5f03c32bf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1800d4d6-8a1e-44bf-ad2f-c6feda9f0b59", "name": "d8ec233b-e55b-463f-83ae-b0ae42abe0e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2e8cf59c-6701-435e-8544-46ba106c78c7"}}}]}, {"uuid": "1e865edd-ffaa-43ba-8b6e-a1d20c8ff803", "name": "load_p1rlv20067_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66a710fb-26c7-4465-b7ea-43ec107008dc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1800d4d6-8a1e-44bf-ad2f-c6feda9f0b59"}}}}, {"uuid": "92818016-ab6d-4337-8604-dcd511bd4151", "name": "2b659a4c-5e5c-44b8-96c0-52aac0b9da6c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a6c90a3d-94da-42ea-be63-43fde770dfde", "name": "f4b0e80f-9d14-4c13-8d38-047e9c58748d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "92818016-ab6d-4337-8604-dcd511bd4151"}}}]}, {"uuid": "7b858e2b-5879-4899-adc7-9d076a7f0ef4", "name": "load_p1rlv20067_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66a710fb-26c7-4465-b7ea-43ec107008dc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a6c90a3d-94da-42ea-be63-43fde770dfde"}}}}, {"uuid": "7677d201-3380-417a-9a52-9ef8fa9dfee1", "name": "63199bcf-5a1a-47bc-8d0a-44308165240b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9909c8b7-5b23-4575-9321-50732255db2a", "name": "3b9e654b-3b09-4b7c-b5b8-3f4660f31a85", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7677d201-3380-417a-9a52-9ef8fa9dfee1"}}}]}, {"uuid": "4152a1b5-d3f7-42db-9171-67392eaf7efd", "name": "load_p1rlv20068_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0b689f0-d4b1-4419-bff8-f72436625c60"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9909c8b7-5b23-4575-9321-50732255db2a"}}}}, {"uuid": "3e63513a-bb72-4d31-a2f9-70ec25c0b612", "name": "9b4bfbff-5ae6-4715-abfa-3af5790cc2d2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8943da66-5e87-482c-b323-437b555f1300", "name": "e7d84638-533e-4bd0-ae06-10a0dd73c4ab", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3e63513a-bb72-4d31-a2f9-70ec25c0b612"}}}]}, {"uuid": "3a0d0e67-4e45-466a-a48b-e5f651e188f6", "name": "load_p1rlv20068_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0b689f0-d4b1-4419-bff8-f72436625c60"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8943da66-5e87-482c-b323-437b555f1300"}}}}, {"uuid": "5605eca0-70bb-4c8b-956a-95ff334d8a43", "name": "f301133a-2df9-4eaf-80fe-f3b6c5d7880f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4037437915385973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5086059213404144, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "273da72e-70f8-4e20-b811-1d5aa8ac1840", "name": "f6722d02-839c-40da-add4-3dd5022b89e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5605eca0-70bb-4c8b-956a-95ff334d8a43"}}}]}, {"uuid": "efba0dc4-178b-4e97-82ec-7abb378997a4", "name": "load_p1rlv20069_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f0e3c74-2d63-4612-b0e5-d986ebee0086"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "273da72e-70f8-4e20-b811-1d5aa8ac1840"}}}}, {"uuid": "d8cb5421-7324-4513-b981-cd8ecdbea96f", "name": "27462fda-ccf8-499d-9b18-ca37ec941ee7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4037437915385973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5086059213404144, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1988d2a9-1029-4430-9f27-d5a16a35948c", "name": "9e4309a5-8321-4913-b06e-df37e6c2ff78", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d8cb5421-7324-4513-b981-cd8ecdbea96f"}}}]}, {"uuid": "398b0ec5-319c-4b3a-acb2-211ad4bd8015", "name": "load_p1rlv20069_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f0e3c74-2d63-4612-b0e5-d986ebee0086"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1988d2a9-1029-4430-9f27-d5a16a35948c"}}}}, {"uuid": "3ba36142-8efd-4af0-aabe-3d6c4e896e98", "name": "19143221-bbf3-412f-a922-844fb1f84b47_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1342890945582846, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10427649324668606, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4beddc3f-4f50-4de9-98bd-a0a3c47d55bb", "name": "420dc19a-c423-4269-929b-8e02f608bb34", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3ba36142-8efd-4af0-aabe-3d6c4e896e98"}}}]}, {"uuid": "ea4428f7-8e83-4552-88eb-60da17163578", "name": "load_p1rlv20070_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "571a4c92-95b6-4bc0-a25d-0d9239a41a89"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4beddc3f-4f50-4de9-98bd-a0a3c47d55bb"}}}}, {"uuid": "70456e11-39d7-47ac-b13e-e03e80311b70", "name": "3281dec8-098a-4ae7-be46-083646516e30_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1342890945582846, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10427649324668606, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4afa5e1a-3342-4e5a-83e8-598613d982bc", "name": "55e58dec-bb57-497a-b7ce-60d7f8574200", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "70456e11-39d7-47ac-b13e-e03e80311b70"}}}]}, {"uuid": "bc306be1-27e3-49cd-a6f3-ed5053de4e79", "name": "load_p1rlv20070_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "571a4c92-95b6-4bc0-a25d-0d9239a41a89"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4afa5e1a-3342-4e5a-83e8-598613d982bc"}}}}, {"uuid": "5f5aa3ad-0611-4475-ac97-843774f3e43a", "name": "388bb2a2-2f73-4610-b003-0829cde0cc95_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.025235929487997, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.9672019739719726, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "497e18cb-741a-46d2-93b0-dcb6dfbbb0ee", "name": "3810dbc5-14a3-413a-9555-92bd8326934b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5f5aa3ad-0611-4475-ac97-843774f3e43a"}}}]}, {"uuid": "6fddd001-4af1-4f25-86b8-830cf26fd999", "name": "load_p1rlv20071_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07f95ba5-92dd-465f-a38d-8e878243262b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "497e18cb-741a-46d2-93b0-dcb6dfbbb0ee"}}}}, {"uuid": "badae621-2271-4fbb-92b9-b7997198bc09", "name": "91f81205-3a31-4aeb-9c65-2bdb639fdc05_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.025235929487997, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.9672019739719726, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "686825c9-98a4-4205-ad4f-b655f3770986", "name": "be7d6cf5-80ec-45c1-9e63-37840f8f0eb5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "badae621-2271-4fbb-92b9-b7997198bc09"}}}]}, {"uuid": "09ab72cc-9134-4f4c-9d62-e7368620535e", "name": "load_p1rlv20071_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07f95ba5-92dd-465f-a38d-8e878243262b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "686825c9-98a4-4205-ad4f-b655f3770986"}}}}, {"uuid": "29885444-289e-4567-ac79-716f71b96499", "name": "d6cacb35-de42-4a55-960a-d2fcc20768b0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7653657521185364, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4426471780914222, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "23605292-f6c1-413b-959f-537dfae499e0", "name": "eb57cc4b-8ee1-44ab-a060-0031eb2d1e1a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "29885444-289e-4567-ac79-716f71b96499"}}}]}, {"uuid": "ea97d3d0-d113-42a9-8f4c-98ccd4431741", "name": "load_p1rlv20130_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ffc82be6-f3f8-4a68-b6e6-da60b137329c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "23605292-f6c1-413b-959f-537dfae499e0"}}}}, {"uuid": "628949c4-d977-44b9-83b5-dfc1b83a448b", "name": "a30ce11a-0069-4dc4-9a77-50344fff2ff4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7653657521185364, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4426471780914222, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a61035e4-5d72-4fb3-9918-8fd2bea3a19e", "name": "a97b7f72-290e-4cc7-942a-142650c7bd59", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "628949c4-d977-44b9-83b5-dfc1b83a448b"}}}]}, {"uuid": "814285a8-0508-4c27-b4cd-6e37590517af", "name": "load_p1rlv20130_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ffc82be6-f3f8-4a68-b6e6-da60b137329c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a61035e4-5d72-4fb3-9918-8fd2bea3a19e"}}}}, {"uuid": "37974511-b79e-4aa4-925a-ae52e6643350", "name": "02ac4d7e-f9c1-4888-8e64-96658f31aa7a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1976836424562762, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1051220183522544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "19a3a383-8f39-431d-a32e-0dfac9c66e47", "name": "4716de37-396d-4f84-9047-19015fc4b6f4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "37974511-b79e-4aa4-925a-ae52e6643350"}}}]}, {"uuid": "67877203-07fb-4971-969c-ca1db78cc7c1", "name": "load_p1rlv20138_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d635a151-2d13-47e9-8043-a214415a5b5e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "19a3a383-8f39-431d-a32e-0dfac9c66e47"}}}}, {"uuid": "329f48ca-3283-47e6-9989-c954e7417b71", "name": "f51afa32-de0f-47ab-a4c2-33c692d05346_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1976836424562762, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1051220183522544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "231b0252-b3b4-443d-99cc-1d0e0bb83657", "name": "e5aa4617-1d5e-460f-9043-0d7d915adec8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "329f48ca-3283-47e6-9989-c954e7417b71"}}}]}, {"uuid": "68a7350c-507f-4869-8bad-6bd0a7069723", "name": "load_p1rlv20138_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d635a151-2d13-47e9-8043-a214415a5b5e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "231b0252-b3b4-443d-99cc-1d0e0bb83657"}}}}, {"uuid": "77e49f4b-b3d3-40b3-834f-4c5168226a08", "name": "5fd864fc-b3a0-438c-9346-f231f66958a9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.839175601618853, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4557221316666175, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "78eab5a8-b3fc-48e7-ac43-fd2dd2da903e", "name": "1f056fd1-addf-4713-8e1b-327857a8743d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "77e49f4b-b3d3-40b3-834f-4c5168226a08"}}}]}, {"uuid": "0667c28e-dd8f-4765-b149-bc0a11a22f81", "name": "load_p1rlv20146_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d615e93-a289-41ec-bda0-3b72bf15677e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "78eab5a8-b3fc-48e7-ac43-fd2dd2da903e"}}}}, {"uuid": "506ef5e7-43e3-4523-9e28-9b4722bf0634", "name": "428b8f72-9bcb-4e02-98fc-1659b2b540e2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.839175601618853, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4557221316666175, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c30682c8-b30f-44c9-908c-fc579a66c330", "name": "1fcbb4ac-279f-46a5-868c-3e5365b9bcc8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "506ef5e7-43e3-4523-9e28-9b4722bf0634"}}}]}, {"uuid": "9b0e659d-e509-4ce2-ba46-cca8bfc2a219", "name": "load_p1rlv20146_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d615e93-a289-41ec-bda0-3b72bf15677e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c30682c8-b30f-44c9-908c-fc579a66c330"}}}}, {"uuid": "8e9732f9-6379-4fd0-ac97-9181c8e829d9", "name": "03898ed5-122c-4c49-b780-cd35835216b3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "afd04a47-3d32-4c66-a95c-2d82fcf9cb75", "name": "913241c2-4cb9-4656-aa6f-c928a21d86df", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8e9732f9-6379-4fd0-ac97-9181c8e829d9"}}}]}, {"uuid": "536437b6-5ff9-472d-a83d-fb5675e57c4a", "name": "load_p1rlv20147_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16b2add7-6a6d-4359-ad6f-f60edf435a4c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "afd04a47-3d32-4c66-a95c-2d82fcf9cb75"}}}}, {"uuid": "3731ebe0-ebd8-47e6-9f23-11292962762b", "name": "76137a33-2e13-4efa-aa08-b7f3288379e1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dc3fa00c-5670-4fcc-914d-cb2e2c2380c9", "name": "6048944f-1622-4c7a-9d8b-15c68d67f7dc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3731ebe0-ebd8-47e6-9f23-11292962762b"}}}]}, {"uuid": "598879fc-5988-40ba-b8b1-b7f009c0bd4b", "name": "load_p1rlv20147_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16b2add7-6a6d-4359-ad6f-f60edf435a4c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dc3fa00c-5670-4fcc-914d-cb2e2c2380c9"}}}}, {"uuid": "f10a8db9-e4a7-409d-9fe0-0a9c827524fe", "name": "d2ab8b89-50f4-4fe5-b697-631e8ee4a2bb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7025097104959883, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.553651846257773, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "09f7234d-2f4c-442f-b595-e940779f8e6f", "name": "18d573c6-341a-43af-9f4b-a773e08d4034", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f10a8db9-e4a7-409d-9fe0-0a9c827524fe"}}}]}, {"uuid": "9cd2c69b-6267-4d9c-8085-cee3d6348e34", "name": "load_p1rlv20148_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4a0c2f2-f75e-4c9c-b3f7-d8d9ada9cb82"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "09f7234d-2f4c-442f-b595-e940779f8e6f"}}}}, {"uuid": "662c15fd-8273-4d2a-826c-d63dd0d541a0", "name": "4d2a8b9a-7a08-41c2-9a1f-d7be80a8fc28_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7025097104959883, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.553651846257773, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "13b2ca4a-12c6-4d03-93e8-8035a24731c4", "name": "1accd70c-77fe-4a8b-9f62-a48f71f4108a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "662c15fd-8273-4d2a-826c-d63dd0d541a0"}}}]}, {"uuid": "7dcaeb95-0db1-4839-81dd-b2ffa143a131", "name": "load_p1rlv20148_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4a0c2f2-f75e-4c9c-b3f7-d8d9ada9cb82"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "13b2ca4a-12c6-4d03-93e8-8035a24731c4"}}}}, {"uuid": "3b7d566a-fd60-40c0-888b-37195221ec56", "name": "1eb5f63e-f4c5-47bc-880a-0419ffdc4f60_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.277248598662887, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.143515736159974, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e3821511-30df-465b-acb5-3df5a9431900", "name": "5a7edf86-266b-48de-b000-e3261d2d65ca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3b7d566a-fd60-40c0-888b-37195221ec56"}}}]}, {"uuid": "682c2dbc-2d9f-46b3-a0fc-e78562e8149f", "name": "load_p1rlv20151_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "956f4975-7383-4e0b-9114-d333a6ec4005"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e3821511-30df-465b-acb5-3df5a9431900"}}}}, {"uuid": "6bb11e99-c093-4512-9392-c9dd988042ea", "name": "0acfd7e0-8c71-493f-9322-f74be44fd197_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.277248598662887, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.143515736159974, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3e0146d7-6870-4a6e-a581-9c1c0b4e462b", "name": "5570bc04-89fc-468f-9de1-40cead4ef94f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6bb11e99-c093-4512-9392-c9dd988042ea"}}}]}, {"uuid": "dce30ee9-99e3-4096-a1d2-edfb09ca8731", "name": "load_p1rlv20151_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "956f4975-7383-4e0b-9114-d333a6ec4005"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3e0146d7-6870-4a6e-a581-9c1c0b4e462b"}}}}, {"uuid": "2101c4d2-a7bb-4ec5-a9e0-472a22d2b9ca", "name": "9375f020-eb43-4a91-90bb-7d3471fee0f3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "da803e70-4bd3-4d0f-8a3b-890e59ec93c0", "name": "b8408681-1c10-4ebc-99ce-10c4bb6796e5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2101c4d2-a7bb-4ec5-a9e0-472a22d2b9ca"}}}]}, {"uuid": "e8b7955f-7191-4b62-a82e-079f0f2abdc7", "name": "load_p1rlv20153_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef20846d-d685-4c65-8dfb-bc23317501c5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "da803e70-4bd3-4d0f-8a3b-890e59ec93c0"}}}}, {"uuid": "1322af1c-d5fb-4850-be2e-41cdd0694ee3", "name": "c062e370-2bf3-4980-8f36-b57052d378a5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9353a53d-fd76-4406-82a0-30c0d857bcd0", "name": "f05ecb8f-2027-458d-9583-302b49f3a150", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1322af1c-d5fb-4850-be2e-41cdd0694ee3"}}}]}, {"uuid": "19356f3f-57d5-443b-94c5-61013aa67221", "name": "load_p1rlv20153_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef20846d-d685-4c65-8dfb-bc23317501c5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9353a53d-fd76-4406-82a0-30c0d857bcd0"}}}}, {"uuid": "582666e3-88bd-4406-b4c6-e73bb4b91ba0", "name": "d0e74089-9406-42cb-968c-941ee84e139e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1698158732703443, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8490689598373361, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "53567545-db94-412e-add3-0c889695de31", "name": "8e64aa07-d1a1-4ea2-907b-ace2c89cb4c5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "582666e3-88bd-4406-b4c6-e73bb4b91ba0"}}}]}, {"uuid": "d8613fd8-c758-4c40-98a7-b36993886851", "name": "load_p1rlv20154_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02f2e50e-d42d-47d1-9274-d840042b64d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "53567545-db94-412e-add3-0c889695de31"}}}}, {"uuid": "40f79b36-4145-4613-88ba-89a19ec6e0bf", "name": "f0e82a30-446e-4f1d-9f99-5d6ca2981ced_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1698158732703443, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8490689598373361, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0edebbfd-e6b6-4891-a964-32309e76baf4", "name": "298418b6-5cc5-4ffd-9476-59d005dbfdaa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "40f79b36-4145-4613-88ba-89a19ec6e0bf"}}}]}, {"uuid": "01e845a4-e721-4c3f-8d26-7cb4412b84df", "name": "load_p1rlv20154_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02f2e50e-d42d-47d1-9274-d840042b64d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0edebbfd-e6b6-4891-a964-32309e76baf4"}}}}, {"uuid": "b32c0a9a-d334-4681-857d-fd8ab3a6549d", "name": "cf52475d-8d2b-425a-a6b6-6bd1227771c0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5577393205082823, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5087722503146331, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "01689471-6c73-4ce9-9bac-cb43ee06a20c", "name": "e5d46a68-b1fc-4ec5-86d7-dd92c1328c97", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b32c0a9a-d334-4681-857d-fd8ab3a6549d"}}}]}, {"uuid": "0819d7bb-f90e-43bd-b41a-14b444d08141", "name": "load_p1rlv20160_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27dfea92-734e-49d3-b245-dc933df66889"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "01689471-6c73-4ce9-9bac-cb43ee06a20c"}}}}, {"uuid": "27394fdb-622e-44b6-81d5-1eb9981f00c6", "name": "6e7dcfe2-6b4d-4558-9672-5295b6aa6270_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5577393205082823, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5087722503146331, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "32efff42-1c9a-4a6a-843c-5a318886d726", "name": "4e734bd3-f26b-482b-a8a8-49499875d26a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "27394fdb-622e-44b6-81d5-1eb9981f00c6"}}}]}, {"uuid": "1d5eca10-7bad-482f-80c6-247f8151e31f", "name": "load_p1rlv20160_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27dfea92-734e-49d3-b245-dc933df66889"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "32efff42-1c9a-4a6a-843c-5a318886d726"}}}}, {"uuid": "0755fb9f-6568-4c32-b652-1f92318543fe", "name": "e5463d44-becb-400d-ba47-359a9bf4eed7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.826891988709754, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.5850639012710004, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9906031f-a5da-425e-addb-376808d02468", "name": "b4611dd5-8fd7-4751-bbe7-21bc6d40f9da", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0755fb9f-6568-4c32-b652-1f92318543fe"}}}]}, {"uuid": "f76f88c6-153e-4c33-a478-49634987fdd8", "name": "load_p1rlv20161_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11a125b8-023c-4748-98a9-d74e9e0a7d23"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9906031f-a5da-425e-addb-376808d02468"}}}}, {"uuid": "440780fa-ac19-42bc-b756-9c76d5ee9ca9", "name": "e4e3cfe7-e4c9-4af4-9494-7498213372f2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.826891988709754, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.5850639012710004, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cd182b10-c001-4a5b-9e43-44dc7c455daa", "name": "6753785b-9a38-40d4-ba64-dc7aeda6e217", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "440780fa-ac19-42bc-b756-9c76d5ee9ca9"}}}]}, {"uuid": "befc5031-d584-4387-97d0-6d05dd3b0f94", "name": "load_p1rlv20161_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11a125b8-023c-4748-98a9-d74e9e0a7d23"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cd182b10-c001-4a5b-9e43-44dc7c455daa"}}}}, {"uuid": "2b9916e3-1cc3-40c2-b106-100fbca32bc4", "name": "f482b61d-a170-49f3-adcd-14b9a9aaa2d0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "12c1a588-267c-4df0-92de-712705362eb2", "name": "d546f682-d596-48d1-8a10-beb069f9b663", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2b9916e3-1cc3-40c2-b106-100fbca32bc4"}}}]}, {"uuid": "3186e30a-1daf-47a1-b3a7-7de94b934a1e", "name": "load_p1rlv20163_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e938635b-e0d2-4e1b-a312-5a8f51e1dd7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "12c1a588-267c-4df0-92de-712705362eb2"}}}}, {"uuid": "40513ecc-0631-4feb-bff0-b823f8acbaee", "name": "c21439ba-4ca7-42c0-b8f4-7897a3e295b8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8bb247fa-584b-4826-a3eb-332fb347f14d", "name": "7dbadad6-bb74-4c3f-be9c-5e5f75360e4a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "40513ecc-0631-4feb-bff0-b823f8acbaee"}}}]}, {"uuid": "973dea5e-dd8c-415b-8833-e13c3546485a", "name": "load_p1rlv20163_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e938635b-e0d2-4e1b-a312-5a8f51e1dd7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8bb247fa-584b-4826-a3eb-332fb347f14d"}}}}, {"uuid": "fc046cf8-edf0-4a1f-8754-5be4bb0b4419", "name": "9aa214a9-ac1c-4ac4-be04-d682e3102515_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3462824541838714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7901197550518754, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82ff972c-2cb6-4f7b-bfe3-e8685c86e393", "name": "5a0f9488-66ab-41bf-876b-3a5ad925add7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fc046cf8-edf0-4a1f-8754-5be4bb0b4419"}}}]}, {"uuid": "61c13976-6f8e-4718-8f43-36f89629245a", "name": "load_p1rlv20182_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20f93381-3834-4265-b1ec-5767d171ce0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "82ff972c-2cb6-4f7b-bfe3-e8685c86e393"}}}}, {"uuid": "f5c5ca8e-be6e-4b48-a905-8cd79528f7df", "name": "e7161faf-4531-4d2d-b504-93f71e0fe967_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3462824541838714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7901197550518754, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4eeebcf3-056a-4f59-af07-063d2c3aebeb", "name": "9d0e8107-35e5-4c97-8abe-24118b0ed9d9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f5c5ca8e-be6e-4b48-a905-8cd79528f7df"}}}]}, {"uuid": "812e9359-28ca-4c4c-846e-f1c369d693f9", "name": "load_p1rlv20182_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20f93381-3834-4265-b1ec-5767d171ce0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4eeebcf3-056a-4f59-af07-063d2c3aebeb"}}}}, {"uuid": "a9830c46-efc9-4e6e-9226-0f99af835107", "name": "b61530f2-b813-4330-9c11-d81eedb917b0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8755168938707782, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2009555085079469, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ee98b128-df25-43d4-87c1-f8fe889abcaa", "name": "2142c271-ebf2-4614-8dde-8b98e597f647", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a9830c46-efc9-4e6e-9226-0f99af835107"}}}]}, {"uuid": "88397929-e8cf-468a-ac8a-28e3eb47a3a0", "name": "load_p1rlv20185_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "646058a3-cda7-4723-bd0f-05d305fe7c11"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ee98b128-df25-43d4-87c1-f8fe889abcaa"}}}}, {"uuid": "0d3ad7f6-d3a8-4024-b3c9-bbb592967dab", "name": "0dde55ff-6f5f-4f03-9926-2b0a217728a2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8755168938707782, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2009555085079469, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "277ea683-fcbe-4395-9b33-9052b99b4481", "name": "6177fe72-01fb-4006-b437-863e53d5a251", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0d3ad7f6-d3a8-4024-b3c9-bbb592967dab"}}}]}, {"uuid": "2fe7edb6-18ed-4a59-9a6f-bfb4d2f50581", "name": "load_p1rlv20185_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "646058a3-cda7-4723-bd0f-05d305fe7c11"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "277ea683-fcbe-4395-9b33-9052b99b4481"}}}}, {"uuid": "6e1a9f5a-f7a2-433b-af26-26c9c15d62fe", "name": "8c5d2dcb-b540-4936-9483-c1517b9a0575_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.554325896527151, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5828877012431191, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6d786114-559e-4567-b1a9-491f2ba465f9", "name": "0c229e2e-de38-4ee7-ac97-67c3b5c717cc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6e1a9f5a-f7a2-433b-af26-26c9c15d62fe"}}}]}, {"uuid": "5847e5be-d646-444e-8211-899235c6ef51", "name": "load_p1rlv20188_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abb24254-be79-45d4-8d9b-246b3e89c00f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6d786114-559e-4567-b1a9-491f2ba465f9"}}}}, {"uuid": "3631cd29-11c0-4a70-b9e6-6177be8b554f", "name": "7f4d2eb1-a8d4-4749-ab9e-e92a0cc31f26_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.554325896527151, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5828877012431191, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "115437c8-e691-44ea-9e83-6dc374bc9259", "name": "5b5dfff3-f56a-4af6-b785-50418eaaec42", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3631cd29-11c0-4a70-b9e6-6177be8b554f"}}}]}, {"uuid": "3f45176f-1df3-4292-bc58-2721e0dee7ef", "name": "load_p1rlv20188_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abb24254-be79-45d4-8d9b-246b3e89c00f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "115437c8-e691-44ea-9e83-6dc374bc9259"}}}}, {"uuid": "49562469-1301-4363-95cd-3046593c0adb", "name": "fcd3d06a-e2dc-452a-b50c-2fbaf06ff7b6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0363799452523006, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8773696756055507, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "da655a3b-6207-4105-b2b5-d69624f20812", "name": "6b8dbe70-8270-40b3-a00b-ecd9df03bb39", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "49562469-1301-4363-95cd-3046593c0adb"}}}]}, {"uuid": "7cf357d4-27c1-4541-8cd7-0855ad1b1dc5", "name": "load_p1rlv20277_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb7a8747-a076-469c-a150-35f6763157ec"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "da655a3b-6207-4105-b2b5-d69624f20812"}}}}, {"uuid": "48452f3a-9d18-4066-8409-178fb47c9120", "name": "369c1a0f-a6e3-4469-a1b5-0acd2f52c8e1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0363799452523006, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8773696756055507, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2f45548d-b2ca-4afd-a1d4-558c5eddf0ff", "name": "73e856f3-f8ba-4274-bcc0-4db94de2ad3f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "48452f3a-9d18-4066-8409-178fb47c9120"}}}]}, {"uuid": "a6be9839-5c1b-4d4f-b05c-c986bb22e30b", "name": "load_p1rlv20277_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb7a8747-a076-469c-a150-35f6763157ec"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2f45548d-b2ca-4afd-a1d4-558c5eddf0ff"}}}}, {"uuid": "d41bcd97-b083-4899-8741-6defb5b6dbb0", "name": "23084baa-fb64-4ed3-a74b-f025044ac26b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1813646779377422, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20173832232537287, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9d614edf-f3c2-4712-99e3-094059223132", "name": "e5308187-bb32-4cfb-8b2b-1f60d283de51", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d41bcd97-b083-4899-8741-6defb5b6dbb0"}}}]}, {"uuid": "a1a5093b-f3d8-4fd9-b381-116dec74cf27", "name": "load_p1rlv20281_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f23405b-432f-45ff-a7b1-0b7147cddfc8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9d614edf-f3c2-4712-99e3-094059223132"}}}}, {"uuid": "71c2e802-a315-4089-9729-f73dd906daee", "name": "b4f5e80a-6212-47ed-9404-91a51057ecd2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1813646779377422, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20173832232537287, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b9ba64f9-1cbc-4a5d-be48-20111b1287ef", "name": "8acbf98f-0273-431c-abf0-20ea79a0bc28", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "71c2e802-a315-4089-9729-f73dd906daee"}}}]}, {"uuid": "1755aad6-21f9-4bb5-b0d6-a7ae5e6b3ad5", "name": "load_p1rlv20281_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f23405b-432f-45ff-a7b1-0b7147cddfc8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b9ba64f9-1cbc-4a5d-be48-20111b1287ef"}}}}, {"uuid": "689f32c9-d186-48b3-a8ec-429949952c0f", "name": "01463a59-3f92-4fbd-baed-8cf8b363221e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2766983969851713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5028612878254624, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3f980f97-c5a3-4719-8006-0b9d4aa8b5a3", "name": "3ba769f6-84c3-4d18-b2a7-f90181ad0bc0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "689f32c9-d186-48b3-a8ec-429949952c0f"}}}]}, {"uuid": "e1d8f0c8-3c29-4b77-acc9-9b57270a4d1a", "name": "load_p1rlv20284_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25837ab0-0fb8-4346-94ad-561ff9ff7f0c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3f980f97-c5a3-4719-8006-0b9d4aa8b5a3"}}}}, {"uuid": "97a52d88-a34a-4ad5-b103-602e9e4264e9", "name": "0200df23-bb54-4357-b643-2d48e26695e3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2766983969851713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5028612878254624, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7902ab99-1ca8-45de-a413-dd2372e8f08c", "name": "42525e2f-3479-401f-b10c-276c5855ea32", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "97a52d88-a34a-4ad5-b103-602e9e4264e9"}}}]}, {"uuid": "5c7ebc0b-5d52-45c2-9464-3daa5289b5de", "name": "load_p1rlv20284_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25837ab0-0fb8-4346-94ad-561ff9ff7f0c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7902ab99-1ca8-45de-a413-dd2372e8f08c"}}}}, {"uuid": "d3ea8fe8-e245-4310-bdcd-c00b9ae6a0a0", "name": "d3bf749d-369b-4f9a-a81f-d7cdd696a223_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.883515343353138, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18989418857380705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c49e716e-4a88-4679-aae4-91b2e7bfd7af", "name": "a8a5d2be-83a1-4e95-8713-add634e266c8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d3ea8fe8-e245-4310-bdcd-c00b9ae6a0a0"}}}]}, {"uuid": "73cd87f9-90e9-426c-8cdb-dd9fae4321f5", "name": "load_p1rlv20296_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a8ae6dc-884d-48d8-9995-fe3936ad019c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c49e716e-4a88-4679-aae4-91b2e7bfd7af"}}}}, {"uuid": "e9a77572-7cc3-44e3-aa73-162851150d07", "name": "ed77ba44-c96a-4c66-b55e-6ad9b009db3e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.883515343353138, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18989418857380705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6e3749ca-15f3-4e70-ba98-cb72a5d62b4d", "name": "23aebaf6-1ac9-49fc-8bff-f7387b987557", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e9a77572-7cc3-44e3-aa73-162851150d07"}}}]}, {"uuid": "209538f5-f332-4d02-adf0-a57fe9255933", "name": "load_p1rlv20296_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a8ae6dc-884d-48d8-9995-fe3936ad019c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6e3749ca-15f3-4e70-ba98-cb72a5d62b4d"}}}}, {"uuid": "674e61df-acfa-4ba9-a25c-a0ef9c3d7234", "name": "52a05c32-4595-4e35-8b75-9dfc10adb02f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.882765489125589, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7706550587664386, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3d96ba4a-9748-4117-9115-0ec6e4a84d97", "name": "f149b8f3-ffe6-4eb8-9c70-3037d949c8ce", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "674e61df-acfa-4ba9-a25c-a0ef9c3d7234"}}}]}, {"uuid": "e583e114-43fa-4279-8479-0a9b6f760cd8", "name": "load_p1rlv20300_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da62d78e-e221-423a-8da0-8d36ce1f7508"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3d96ba4a-9748-4117-9115-0ec6e4a84d97"}}}}, {"uuid": "231f7ff9-e2a6-422f-868e-484d14a19fb3", "name": "61ae5d4b-8e33-4476-9faf-c4e177b90cfc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.882765489125589, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7706550587664386, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "814c2e34-5564-4e3c-b825-299f449c1549", "name": "6647d065-688f-4a0c-be0e-57e96810df79", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "231f7ff9-e2a6-422f-868e-484d14a19fb3"}}}]}, {"uuid": "8167385d-15e1-43ed-87a9-157820a44468", "name": "load_p1rlv20300_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da62d78e-e221-423a-8da0-8d36ce1f7508"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "814c2e34-5564-4e3c-b825-299f449c1549"}}}}, {"uuid": "a69441e7-20bf-4633-9680-549d96bc42b5", "name": "e26b65fb-b834-4d3d-abd7-e0398420cb28_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.693241087582845, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5112522017919784, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10eadc14-2c10-4e7e-9c68-5db44d506d7d", "name": "9dacf371-4b31-4a2a-a482-d985e56df868", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a69441e7-20bf-4633-9680-549d96bc42b5"}}}]}, {"uuid": "c60d84a8-585f-4b23-9e8f-683aaaf84f41", "name": "load_p1rlv20309_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e5718ad-0b70-4ea4-b2f2-31f0ea5c5d5b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10eadc14-2c10-4e7e-9c68-5db44d506d7d"}}}}, {"uuid": "3845555f-4b62-4dfc-b4b7-37d8efd82575", "name": "604a9fac-d7a2-44b0-8c14-02e979a21980_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.693241087582845, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5112522017919784, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3061bc64-6954-4cb0-af8c-42bea15eb1ff", "name": "8711a927-6ff3-4819-b6d6-1e02c035eaeb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3845555f-4b62-4dfc-b4b7-37d8efd82575"}}}]}, {"uuid": "d2319eca-b2e2-493f-bbc5-9c465e6d19f1", "name": "load_p1rlv20309_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e5718ad-0b70-4ea4-b2f2-31f0ea5c5d5b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3061bc64-6954-4cb0-af8c-42bea15eb1ff"}}}}, {"uuid": "ab26b536-8e98-4cbd-826e-632038c7aa68", "name": "43a3ddac-87b5-4f7d-a777-e36b7cd087a7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.771789007275423, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6748983225226206, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "94e5a2f6-c580-487f-b991-e648af18c2b3", "name": "789e3f04-ec58-4372-a305-0e7d67f232dd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ab26b536-8e98-4cbd-826e-632038c7aa68"}}}]}, {"uuid": "67d5a93f-9cc6-4996-875a-ead4a2259149", "name": "load_p1rlv20333_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c23afdc0-ab93-4d43-8eec-613eab21cd74"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "94e5a2f6-c580-487f-b991-e648af18c2b3"}}}}, {"uuid": "1f0b1832-82ee-4ba8-8223-466b960951ce", "name": "846779ae-8e22-4d09-81e5-17492a80c258_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.771789007275423, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6748983225226206, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ef8fd0ff-288b-430f-b0cf-cda84570432d", "name": "739f4418-858f-4ed2-9995-c7d33f959819", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1f0b1832-82ee-4ba8-8223-466b960951ce"}}}]}, {"uuid": "63ab5d3b-31a1-40da-b0d8-5e02c8252274", "name": "load_p1rlv20333_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c23afdc0-ab93-4d43-8eec-613eab21cd74"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ef8fd0ff-288b-430f-b0cf-cda84570432d"}}}}, {"uuid": "2c59ab6a-27f7-4bf4-b196-491740e3eea2", "name": "1bf779d5-b9fb-4c49-a1ec-8c5e9c95ad86_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4663769608466568, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5502546109327153, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f0b41a56-9e28-4e39-853a-5fd6b3a3f759", "name": "35f13eff-e9a2-464e-9b8c-a394a22fba9c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2c59ab6a-27f7-4bf4-b196-491740e3eea2"}}}]}, {"uuid": "947a6e02-28d8-48d0-a08b-2755c2ef0a5a", "name": "load_p1rlv20358_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b5d2dfa-895b-4afc-a7fe-449960adba41"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f0b41a56-9e28-4e39-853a-5fd6b3a3f759"}}}}, {"uuid": "f2d0f53c-e96d-4415-9be7-7c18d2921e78", "name": "1d8dc242-b4c0-4991-a303-dd2696fd8062_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4663769608466568, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5502546109327153, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "add10e60-b423-40da-9574-89fe3fd70430", "name": "dab80639-1aba-48f6-82a0-59a1e3a61146", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f2d0f53c-e96d-4415-9be7-7c18d2921e78"}}}]}, {"uuid": "1ff5e68d-e4ac-4cbf-ab60-fa72da086e84", "name": "load_p1rlv20358_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b5d2dfa-895b-4afc-a7fe-449960adba41"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "add10e60-b423-40da-9574-89fe3fd70430"}}}}, {"uuid": "b721e110-586f-4991-b001-e8231b9a661a", "name": "4f4600d5-3b68-43ae-9fc4-682eb9a82ec5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.234980013002153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7303750309107965, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "84307684-e352-4ed0-8167-f34fd87e6a0e", "name": "a37056e5-15cf-46ee-a399-2919d04cef17", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b721e110-586f-4991-b001-e8231b9a661a"}}}]}, {"uuid": "24a685f1-f697-42a7-8baf-26bd8d3a777c", "name": "load_p1rlv20432_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4b5327a-85a3-496c-859c-f887a38513cd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "84307684-e352-4ed0-8167-f34fd87e6a0e"}}}}, {"uuid": "cfe04cf1-1d36-49b4-8437-1c3cfb4ad9ac", "name": "fe88a424-87cc-4d87-8469-62f10e845aae_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.234980013002153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7303750309107965, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dad3dd9c-6e71-48c0-bfcf-864ab6075d33", "name": "5b53255a-f320-42bd-b033-28f0ee0d898d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cfe04cf1-1d36-49b4-8437-1c3cfb4ad9ac"}}}]}, {"uuid": "b338d19c-0240-4a2f-a921-41e0f09d9388", "name": "load_p1rlv20432_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4b5327a-85a3-496c-859c-f887a38513cd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dad3dd9c-6e71-48c0-bfcf-864ab6075d33"}}}}, {"uuid": "2f56313c-3d79-46a7-a0ca-9d045bd29bea", "name": "582f7ddf-5577-4b76-a74c-572604dea4bc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.875485744114147, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.294896241985991, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1702993d-c1f9-4973-b193-3a8585e423a0", "name": "c096483d-27aa-424a-ab54-603c3cb0b381", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2f56313c-3d79-46a7-a0ca-9d045bd29bea"}}}]}, {"uuid": "883a1c8e-13a5-43b7-8fcf-15e3d109de8d", "name": "load_p1rlv20450_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "006c2753-37b3-4b59-82a6-8ce95f316e26"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1702993d-c1f9-4973-b193-3a8585e423a0"}}}}, {"uuid": "ce653358-2d5e-4f72-b43b-295514bc1cad", "name": "cc6468ed-786c-4572-82a8-5d6b57b04a3b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.875485744114147, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.294896241985991, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "18b9c629-85b9-42dc-ab5d-6d5c3b3071cc", "name": "82ea8c9f-863a-4388-a0ae-d3d2203bccbc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ce653358-2d5e-4f72-b43b-295514bc1cad"}}}]}, {"uuid": "b534e7d7-118c-4848-95ae-fcc2f4ed6e5f", "name": "load_p1rlv20450_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "006c2753-37b3-4b59-82a6-8ce95f316e26"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "18b9c629-85b9-42dc-ab5d-6d5c3b3071cc"}}}}, {"uuid": "5b9b6951-75e2-4637-a256-d849e3b06acf", "name": "656a36cf-f25b-4120-8099-158fe0f59230_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b8a0bdaa-7756-4107-b440-71e5df460e62", "name": "18d974a3-94a5-4caa-bd9f-2a1e5338cd51", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b9b6951-75e2-4637-a256-d849e3b06acf"}}}]}, {"uuid": "dd86f627-1fdb-4186-8fd2-5a821ad6b167", "name": "load_p1rlv20451_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c37708d8-1e83-4e76-ac7f-0d29ba6b7c4e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b8a0bdaa-7756-4107-b440-71e5df460e62"}}}}, {"uuid": "2c4105ad-2941-4a5e-8da0-084fe4c47413", "name": "358342e3-0ff1-4fbe-bfe9-b931af7cada5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "11e14820-7282-4d71-a652-1df122e93ae3", "name": "ed38027a-bde9-4103-bada-f0cbe9f21e63", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2c4105ad-2941-4a5e-8da0-084fe4c47413"}}}]}, {"uuid": "d0489582-81ad-47e8-ac14-e3d9782482a9", "name": "load_p1rlv20451_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c37708d8-1e83-4e76-ac7f-0d29ba6b7c4e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "11e14820-7282-4d71-a652-1df122e93ae3"}}}}, {"uuid": "04a63073-b106-4c96-af0d-750e7142c296", "name": "3789b483-2c9e-4cdc-850b-1f6a72bcef77_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.250267265771566, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8009319586825154, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f16238df-3368-4a62-8c92-7c5c72897070", "name": "fa0828f4-8786-4eab-b890-f711c0f4100e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "04a63073-b106-4c96-af0d-750e7142c296"}}}]}, {"uuid": "81cb1766-7c52-4734-b2c2-41c66ce8a702", "name": "load_p1rlv20453_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4e21b79-d2be-4a53-be46-32331e61f89c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f16238df-3368-4a62-8c92-7c5c72897070"}}}}, {"uuid": "d5049aa4-9273-407c-94cf-05ca8a440bb5", "name": "9aed6232-19be-49ed-8f87-15b4a5c57259_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.250267265771566, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8009319586825154, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82923a7e-5484-4585-9ca1-a210dbd4353c", "name": "f8f24d31-bdc4-422b-bb31-6ea4a915fff6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d5049aa4-9273-407c-94cf-05ca8a440bb5"}}}]}, {"uuid": "3130ec59-302e-4764-b6ec-7a2c174c82fc", "name": "load_p1rlv20453_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4e21b79-d2be-4a53-be46-32331e61f89c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "82923a7e-5484-4585-9ca1-a210dbd4353c"}}}}, {"uuid": "5fed4409-884d-4852-aaca-6254e421f131", "name": "48f05232-d2cd-4c7f-b426-e33a74da8e37_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8249779386922644, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12555321354723425, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5cf1d9db-65c5-40e1-a2ad-8266c84ccbeb", "name": "45f27dfc-ed96-4912-abc5-76bb39a907a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5fed4409-884d-4852-aaca-6254e421f131"}}}]}, {"uuid": "d759ae69-49ba-4eae-9068-7d6580520328", "name": "load_p1rlv20455_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8934db59-0c39-4838-9f8c-59a563cd9d54"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5cf1d9db-65c5-40e1-a2ad-8266c84ccbeb"}}}}, {"uuid": "229b6a23-244e-4532-9a35-bca51bcf0c42", "name": "59d624f6-8c91-48de-bad6-4f0278258187_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8249779386922644, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12555321354723425, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cef84716-de5d-4d70-ac0d-8789997937fd", "name": "f1b9614f-d493-439e-8adb-16d290302ab6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "229b6a23-244e-4532-9a35-bca51bcf0c42"}}}]}, {"uuid": "dcfeb706-43bf-4843-a816-558d7581b181", "name": "load_p1rlv20455_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8934db59-0c39-4838-9f8c-59a563cd9d54"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cef84716-de5d-4d70-ac0d-8789997937fd"}}}}, {"uuid": "6d1cbd3e-0a5d-405e-b2a1-5a12b82418ab", "name": "7d23ff30-ed71-4481-9b7e-5f6e41217722_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8374792851175116, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3203908676737591, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "84f5cd6e-2311-496e-b43d-4ca722b1bd78", "name": "663baad0-b0d9-45a7-927e-a0e5745d093d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6d1cbd3e-0a5d-405e-b2a1-5a12b82418ab"}}}]}, {"uuid": "15618555-50c1-4539-9f13-79af73f29385", "name": "load_p1rlv20456_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7a43aa6-2be8-4320-8089-57d388633c6b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "84f5cd6e-2311-496e-b43d-4ca722b1bd78"}}}}, {"uuid": "3d0161c8-eb1c-4ee5-9650-143e945be3cf", "name": "0532cf22-4356-42b2-9e53-0041df647378_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8374792851175116, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3203908676737591, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e1f2743d-7186-44c8-8f9a-eaa189699efd", "name": "92bd0fa1-7f76-4bc0-9d50-9025b4331053", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3d0161c8-eb1c-4ee5-9650-143e945be3cf"}}}]}, {"uuid": "287913e4-5259-480f-8263-e9c579b303b3", "name": "load_p1rlv20456_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7a43aa6-2be8-4320-8089-57d388633c6b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e1f2743d-7186-44c8-8f9a-eaa189699efd"}}}}, {"uuid": "34dc3d17-22d5-4269-b173-57f37f258b5d", "name": "a7178ff2-912b-40c4-83e7-d36982eb2cf3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "daccca9a-4139-4678-8213-c2c1a0d5452b", "name": "c42dc409-047a-4727-b120-e73d258a5d04", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "34dc3d17-22d5-4269-b173-57f37f258b5d"}}}]}, {"uuid": "0427d862-2997-45d5-8577-931c32fbd39d", "name": "load_p1rlv20459_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dfcfdbf-0051-4eef-bea6-97446cee21e4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "daccca9a-4139-4678-8213-c2c1a0d5452b"}}}}, {"uuid": "945cb6b6-8779-42d6-9cb7-b12d175781b1", "name": "bdf587e2-5289-4da2-966b-c4c582a9b1eb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ef5f0664-db91-4bdd-8bb9-3db366347fb4", "name": "6b3f9973-e997-4894-b53c-4f7487109a22", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "945cb6b6-8779-42d6-9cb7-b12d175781b1"}}}]}, {"uuid": "4fa9fb29-e1fd-4f0c-9408-5b718718758e", "name": "load_p1rlv20459_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dfcfdbf-0051-4eef-bea6-97446cee21e4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ef5f0664-db91-4bdd-8bb9-3db366347fb4"}}}}, {"uuid": "401ed287-96c4-47ad-bb6b-c09376d9100b", "name": "fbb8c89b-8c5f-4ce4-ac79-225a79a3328c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8140781365796688, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5845737413475921, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "41ccd785-e72f-49fe-8791-f254aa1574ef", "name": "1b19f048-ac7a-4b40-bfe7-bc60a1426077", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "401ed287-96c4-47ad-bb6b-c09376d9100b"}}}]}, {"uuid": "8793d403-b23e-48cc-9bd9-4c73108709e0", "name": "load_p1rlv20465_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4759390d-43ec-45c9-9cca-320020dc1150"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "41ccd785-e72f-49fe-8791-f254aa1574ef"}}}}, {"uuid": "7fe82b55-5c16-40c9-b10e-5bc64c7fc02d", "name": "b5e45d5d-1bf7-4a54-a0d0-98e9e7e76ef7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8140781365796688, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5845737413475921, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f8024279-8d0b-4396-80aa-b0ebebd0bb90", "name": "18145921-4d73-4934-baed-7944f959f685", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7fe82b55-5c16-40c9-b10e-5bc64c7fc02d"}}}]}, {"uuid": "1ccceec8-8328-4dad-825d-786eb05ffcf0", "name": "load_p1rlv20465_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4759390d-43ec-45c9-9cca-320020dc1150"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f8024279-8d0b-4396-80aa-b0ebebd0bb90"}}}}, {"uuid": "ec91887c-9c4e-45fb-9283-1d9509dc8801", "name": "69b9e34b-1f8a-4670-bfba-5681e8c2ea10_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "565c66a1-9d75-4eb6-9103-dd216b5b89de", "name": "0d7f9147-a203-4140-96f3-5d6a51114635", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ec91887c-9c4e-45fb-9283-1d9509dc8801"}}}]}, {"uuid": "0d76342c-2396-4214-a4bf-f456d4521254", "name": "load_p1rlv20467_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58e2b774-ac04-435e-9e03-573b3aa94cfb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "565c66a1-9d75-4eb6-9103-dd216b5b89de"}}}}, {"uuid": "329fcd7f-6421-421b-a1e9-a0c9774a3398", "name": "c992e272-c468-4173-b205-553f230c7f23_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "83d890be-1de3-4c73-b7f3-4533594fb921", "name": "963b00b2-8d48-461e-aa6b-f857cca4ce80", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "329fcd7f-6421-421b-a1e9-a0c9774a3398"}}}]}, {"uuid": "8018e55d-e577-4e29-81d2-c6b758885388", "name": "load_p1rlv20467_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58e2b774-ac04-435e-9e03-573b3aa94cfb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "83d890be-1de3-4c73-b7f3-4533594fb921"}}}}, {"uuid": "7a1018dc-731c-4c84-8596-ccae7cce63bf", "name": "a66deca1-7605-4fe6-af3e-a2b629aaaf29_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9559171691321495, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6431a71d-fb58-4b2b-8728-b2f14b275221", "name": "99a19f84-1a9f-4e1c-8ba7-d9c94a2d0e14", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7a1018dc-731c-4c84-8596-ccae7cce63bf"}}}]}, {"uuid": "3d34d545-10cb-4ec2-844c-f8aa84b45fdb", "name": "load_p1rlv20469_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60fe0a16-aa4d-4fe8-9f39-81bfa13b505f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6431a71d-fb58-4b2b-8728-b2f14b275221"}}}}, {"uuid": "fc3a51b6-688a-4fe9-8c0f-4da7edd2e08e", "name": "ad5093ab-3779-47c2-834b-3b4c0e4ff47c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9559171691321495, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f374207e-cb43-4462-a20a-bc0597568d97", "name": "62de9be0-ce10-4551-ae7a-ecfc395afad7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fc3a51b6-688a-4fe9-8c0f-4da7edd2e08e"}}}]}, {"uuid": "7a2fe99a-ab27-4605-a90e-794c1864d276", "name": "load_p1rlv20469_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60fe0a16-aa4d-4fe8-9f39-81bfa13b505f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f374207e-cb43-4462-a20a-bc0597568d97"}}}}, {"uuid": "9652105b-26c8-43e1-86c9-fa3508510c4b", "name": "695f24d1-bcff-4c46-96de-e6e71d9e5aaf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.772705532239135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.33568286747913667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5091744d-12e4-4e1b-8838-937c50b63054", "name": "8675ddbe-5371-4ce2-a56e-5ec053964822", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9652105b-26c8-43e1-86c9-fa3508510c4b"}}}]}, {"uuid": "9745b2e8-cce1-42d7-bcb4-17d99d414e3e", "name": "load_p1rlv20473_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3eb214b9-827f-4995-a862-907be02b029d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5091744d-12e4-4e1b-8838-937c50b63054"}}}}, {"uuid": "be39e594-4f05-4bee-9b74-0fac136bb8ec", "name": "bc764a14-2cde-40d3-b6d5-84493c3f6efd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.772705532239135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.33568286747913667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d0a874a8-6ba0-4050-a7cc-c432c61f2415", "name": "15c7b000-6321-4bef-bfa7-4977989eaf80", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "be39e594-4f05-4bee-9b74-0fac136bb8ec"}}}]}, {"uuid": "52a31c24-3b82-4447-8912-06dbd691546d", "name": "load_p1rlv20473_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3eb214b9-827f-4995-a862-907be02b029d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d0a874a8-6ba0-4050-a7cc-c432c61f2415"}}}}, {"uuid": "1d21b064-5365-4048-872a-21abd9d21293", "name": "203c3bda-70e3-493b-b693-f5588be13c2f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "735cda5d-5016-48cd-aaa0-463cd519da98", "name": "157da864-e8b2-4903-b5ed-8c0fe72c4782", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1d21b064-5365-4048-872a-21abd9d21293"}}}]}, {"uuid": "80f467e5-7f90-44a6-8356-7cf7914e5f6d", "name": "load_p1rlv20478_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cd0effe0-d186-41a8-8197-24144fbc6218"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "735cda5d-5016-48cd-aaa0-463cd519da98"}}}}, {"uuid": "7709f9bd-c129-48d8-b9a6-eb8ed8f0e5f1", "name": "068ba0fc-60a4-41bf-bd57-90aea5217b06_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5fb3ed72-dd15-40c3-9fe4-84422b9d980e", "name": "dc761561-95d5-4345-a360-e22a514fd231", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7709f9bd-c129-48d8-b9a6-eb8ed8f0e5f1"}}}]}, {"uuid": "6c849935-fc6e-4c1e-9641-f6249caab38e", "name": "load_p1rlv20478_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cd0effe0-d186-41a8-8197-24144fbc6218"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5fb3ed72-dd15-40c3-9fe4-84422b9d980e"}}}}, {"uuid": "fd483ed2-68e3-445f-b375-06f936328d53", "name": "3d0dde73-4edb-4ff9-81ec-866af2313355_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4437884187508536, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6647073432497462, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "564d4ca5-373b-4f67-b677-422237e5ea0c", "name": "81315c28-c714-483b-af7d-e470c300d902", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fd483ed2-68e3-445f-b375-06f936328d53"}}}]}, {"uuid": "eade93de-ff75-4263-ab36-37f6392c70f8", "name": "load_p1rlv20480_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5d0a174-d49d-4c7e-a669-092f6408edf4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "564d4ca5-373b-4f67-b677-422237e5ea0c"}}}}, {"uuid": "1ce17efe-78d1-4851-ac9e-8ade9592e23b", "name": "bcf26ca4-bb62-446c-ba60-137cc3419286_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4437884187508536, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6647073432497462, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5d58b329-940f-499f-99e1-f5e6ebdd66d0", "name": "c2488af4-3aee-404f-9a2b-844cc1c7ef27", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1ce17efe-78d1-4851-ac9e-8ade9592e23b"}}}]}, {"uuid": "d89233ce-3b5c-40c2-8148-39cb020e8556", "name": "load_p1rlv20480_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5d0a174-d49d-4c7e-a669-092f6408edf4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5d58b329-940f-499f-99e1-f5e6ebdd66d0"}}}}, {"uuid": "39cdc73d-09f9-44e8-822c-9c513c93ff9e", "name": "565e2c77-bd5f-48f1-a5b6-232fd14fd774_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.109177669729331, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5486693289215298, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "66863d2d-5d48-44a0-996e-27f9e773740f", "name": "0cd7736a-ed87-4516-b385-4b23997e7ddd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "39cdc73d-09f9-44e8-822c-9c513c93ff9e"}}}]}, {"uuid": "3be81848-c16d-4e15-8043-56eab74dec44", "name": "load_p1rlv20492_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7af262b7-285c-4d06-b7ff-2f2a1971055a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "66863d2d-5d48-44a0-996e-27f9e773740f"}}}}, {"uuid": "3f800f84-d5ef-474a-be18-715755ebc8ca", "name": "cad3c948-664a-4ddd-a2ae-731cf726bb28_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.109177669729331, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5486693289215298, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f657e04d-89e2-439a-b2c5-dcdcbc637963", "name": "3c70cbae-4ecd-4f93-a71d-6ae728057831", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3f800f84-d5ef-474a-be18-715755ebc8ca"}}}]}, {"uuid": "cc77e7e8-e03c-4713-b2fa-215d3f2c2243", "name": "load_p1rlv20492_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7af262b7-285c-4d06-b7ff-2f2a1971055a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f657e04d-89e2-439a-b2c5-dcdcbc637963"}}}}, {"uuid": "39a51d11-5f0c-46c0-b4c7-2af2dd954ebc", "name": "81a41b58-eb9a-4539-a878-7dba2c28b143_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9444657359992037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.058006608995704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "37b07b41-077a-45c0-9324-13d6a7ba74d4", "name": "de4576f0-f6f8-4e80-8ef6-1773aa55e02e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "39a51d11-5f0c-46c0-b4c7-2af2dd954ebc"}}}]}, {"uuid": "2909b0c0-845f-4562-af72-2f9305e7abba", "name": "load_p1rlv20499_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af153ed-ed39-4433-ac12-19dfdb7b6bef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "37b07b41-077a-45c0-9324-13d6a7ba74d4"}}}}, {"uuid": "fb25be19-608e-41ef-9a56-cfd291dce449", "name": "a6005aed-4468-4377-9284-35ef79ff1428_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9444657359992037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.058006608995704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5ad5caa6-9a08-49c6-904c-a1a531c6ef73", "name": "2e525d33-9f5a-4a97-b599-023512e9421b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fb25be19-608e-41ef-9a56-cfd291dce449"}}}]}, {"uuid": "4a126325-c6b8-473a-a8f8-57f06397f106", "name": "load_p1rlv20499_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af153ed-ed39-4433-ac12-19dfdb7b6bef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5ad5caa6-9a08-49c6-904c-a1a531c6ef73"}}}}, {"uuid": "6d3471e3-3363-42fc-9259-5602fc27ed6c", "name": "1b7f7368-03e3-49c2-aca1-32a570bc7c83_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7956093485713416, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7629429667228578, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "373e538b-b9e4-4ca6-a1f2-6f2097d56b4b", "name": "b4accc81-346a-4c78-adb5-a3e46f18d6ca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6d3471e3-3363-42fc-9259-5602fc27ed6c"}}}]}, {"uuid": "46bb7b31-1c51-4577-a18f-e029061f6d23", "name": "load_p1rlv20502_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cacd3e49-55aa-4f05-bd7d-ae8aba0af87f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "373e538b-b9e4-4ca6-a1f2-6f2097d56b4b"}}}}, {"uuid": "8288e370-9098-494a-965c-85088e722ff3", "name": "05b0d269-5681-4ae5-888d-3811295a6736_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7956093485713416, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7629429667228578, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "141d6878-08dd-4335-838c-ad91b1d41622", "name": "a2055bd1-9ce8-4515-a48e-55eec6b1e260", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8288e370-9098-494a-965c-85088e722ff3"}}}]}, {"uuid": "d8f4b17f-af30-4202-a34d-50a18a3b0803", "name": "load_p1rlv20502_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cacd3e49-55aa-4f05-bd7d-ae8aba0af87f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "141d6878-08dd-4335-838c-ad91b1d41622"}}}}, {"uuid": "3359d395-ff77-4ea4-9c0c-99736773de9c", "name": "32c12bb3-5eca-41a1-99de-3f8946788258_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1419f1bb-43f7-42df-90f7-d852fab4f04f", "name": "a1ab948c-b0c8-467b-8e1d-009a593a9d49", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3359d395-ff77-4ea4-9c0c-99736773de9c"}}}]}, {"uuid": "f5b597dd-6be9-4387-86cd-b9353cfb2945", "name": "load_p1rlv20504_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b3e7495-7732-42ce-8d53-a5f1b7383ce4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1419f1bb-43f7-42df-90f7-d852fab4f04f"}}}}, {"uuid": "1b9c8237-cdcc-4788-8dc9-a2e38cae3cfd", "name": "9fc3d9d1-be67-42d0-b13b-fbe934a1f866_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10916cfb-46ea-418a-9fe5-97fc48b4b6ef", "name": "0f24b9ae-8dad-43d2-9345-f895af4434c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1b9c8237-cdcc-4788-8dc9-a2e38cae3cfd"}}}]}, {"uuid": "d4de4534-9b56-46f9-80ab-765f25e29ca7", "name": "load_p1rlv20504_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b3e7495-7732-42ce-8d53-a5f1b7383ce4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10916cfb-46ea-418a-9fe5-97fc48b4b6ef"}}}}, {"uuid": "c9eb1619-3c3d-4f08-8a82-c8c2946520b8", "name": "cbf50237-7e76-43f1-a222-375cca9e6ed2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4699462180170992, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3815978523472859, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9432afde-7c88-4d3e-868e-97f3205456a3", "name": "6d2fbc95-5243-4480-99fe-ceee1232380c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9eb1619-3c3d-4f08-8a82-c8c2946520b8"}}}]}, {"uuid": "b276dd5f-841c-4c7a-aa73-fbd5e223bf2f", "name": "load_p1rlv20509_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fe37b51-0258-4812-9d96-3cc28c4bd55b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9432afde-7c88-4d3e-868e-97f3205456a3"}}}}, {"uuid": "c8c20fa6-a023-4e8d-a933-7d2719c5465a", "name": "42b7aab2-d56b-4355-88df-e601c8f31bdb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4699462180170992, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3815978523472859, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e7ded97f-bbc4-4b6f-ae64-81781795ede1", "name": "c378b47a-4b56-42f7-8cc0-a1aeeffc51c8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c8c20fa6-a023-4e8d-a933-7d2719c5465a"}}}]}, {"uuid": "f4dfab8b-a25e-41f8-a9f4-e82697795162", "name": "load_p1rlv20509_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fe37b51-0258-4812-9d96-3cc28c4bd55b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e7ded97f-bbc4-4b6f-ae64-81781795ede1"}}}}, {"uuid": "9bf4e191-bba9-4688-86c3-11e2a3b1556c", "name": "486fa29e-1442-4521-b654-5df94e5acf1b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.996798907530164, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8717719006522443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "22e04164-803c-48f5-a56d-12cf40f867a1", "name": "d9db1151-69f7-4de1-9369-643383b87847", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9bf4e191-bba9-4688-86c3-11e2a3b1556c"}}}]}, {"uuid": "d09f7d54-3513-4a3b-bf4f-7fda658684de", "name": "load_p1rlv38126_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa4eed95-33b7-4827-8744-52d14149b386"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "22e04164-803c-48f5-a56d-12cf40f867a1"}}}}, {"uuid": "6736f48a-4c11-43b4-891f-9f29b71f0493", "name": "cd2cfbb2-88c7-4456-88bb-e68221dbd5bf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.996798907530164, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8717719006522443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ca6624d5-7866-48be-9078-6446a8a1c9d2", "name": "9a1029dd-92d1-4ec6-b1c5-2b26f4e507e6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6736f48a-4c11-43b4-891f-9f29b71f0493"}}}]}, {"uuid": "948ee14d-09ae-452c-9a1a-fe2b0b24d3d2", "name": "load_p1rlv38126_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa4eed95-33b7-4827-8744-52d14149b386"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ca6624d5-7866-48be-9078-6446a8a1c9d2"}}}}, {"uuid": "5a62a170-8408-4aee-ac89-b87283b59ca9", "name": "492571f6-4b8e-4149-8af4-782cf955b9e6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.771789007275423, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6748983225226206, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2bc2e514-fab8-4c9f-b7b8-411b8efda667", "name": "9501e8c1-8685-4967-a88e-abf0af5efe9d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5a62a170-8408-4aee-ac89-b87283b59ca9"}}}]}, {"uuid": "397cd87a-7d75-4f45-aa6f-52fe2df03ef8", "name": "load_p1rlv38269_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cbb9976-253c-4863-899f-9218c4496688"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2bc2e514-fab8-4c9f-b7b8-411b8efda667"}}}}, {"uuid": "5214f41f-f6cf-482d-a6ea-e38a09940a99", "name": "0a35ab40-62f0-409a-b114-8c09acffbd43_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.771789007275423, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6748983225226206, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5352644d-0db9-4d77-a7a8-6e0a66ca84b7", "name": "c2b502d9-0a08-4b93-9f2c-0c0ce6dd602b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5214f41f-f6cf-482d-a6ea-e38a09940a99"}}}]}, {"uuid": "fa091356-cbf4-4839-924a-1f6693e3ebbf", "name": "load_p1rlv38269_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cbb9976-253c-4863-899f-9218c4496688"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5352644d-0db9-4d77-a7a8-6e0a66ca84b7"}}}}, {"uuid": "64759ea8-ca8d-455d-ad79-a86f6f4c1078", "name": "2f2a96b2-f5cc-4111-9081-3f1c4b1fe5cd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.981510789736824, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31377757670385525, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "22684b35-2628-4241-8a5b-8bb62902e667", "name": "ddc680e4-e90e-4c70-9b8a-9d25ea26c9d4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "64759ea8-ca8d-455d-ad79-a86f6f4c1078"}}}]}, {"uuid": "02800fdd-973c-4ea6-947e-16920dc24b19", "name": "load_p1rlv51_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ccef6af-4bf6-44dc-b292-2bf9503a374a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "22684b35-2628-4241-8a5b-8bb62902e667"}}}}, {"uuid": "d369ec5a-9562-4ae3-9425-61193f466f3d", "name": "7255ae90-e0cc-4211-a37d-c7c594174568_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.981510789736824, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31377757670385525, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b3a1c1ea-ecc3-4918-9a3e-a9f251be8050", "name": "ce92b254-0249-4534-aa24-f59f9a14d49e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d369ec5a-9562-4ae3-9425-61193f466f3d"}}}]}, {"uuid": "b960c0ed-e728-42b5-ac3e-4f16188cf698", "name": "load_p1rlv51_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ccef6af-4bf6-44dc-b292-2bf9503a374a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b3a1c1ea-ecc3-4918-9a3e-a9f251be8050"}}}}, {"uuid": "61de8132-a291-4b6f-b49b-0b80c583fa54", "name": "13eef270-75e1-49cd-8450-61946b6a081a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5300176124233262, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6781680527999017, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d2143736-d7cb-4e9f-afd6-b762c6c77b83", "name": "96862f7e-44cc-4402-84fc-0a409a7fa1cf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "61de8132-a291-4b6f-b49b-0b80c583fa54"}}}]}, {"uuid": "dc46ae74-9f32-4dee-a22d-5d2f43234fac", "name": "load_p1rlv52_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fec0a162-4b0c-4577-b878-8dbc7c9935fc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d2143736-d7cb-4e9f-afd6-b762c6c77b83"}}}}, {"uuid": "51693030-21ed-433c-b940-8ddbee99ba4d", "name": "94e31f3c-0b45-4c7f-bb84-7f07ffa8a8c2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5300176124233262, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6781680527999017, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "851be08c-93cb-4463-b140-7ed120d378ce", "name": "72332b31-1f7b-4287-a60c-aedf13b24f80", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "51693030-21ed-433c-b940-8ddbee99ba4d"}}}]}, {"uuid": "81a65548-4893-4ebc-9d8f-1b53055dd9e2", "name": "load_p1rlv52_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fec0a162-4b0c-4577-b878-8dbc7c9935fc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "851be08c-93cb-4463-b140-7ed120d378ce"}}}}, {"uuid": "6abbf5df-fbd7-4a80-b490-df552d7a8b46", "name": "b47ca072-cfb7-4733-ad27-193f2f0bfe6b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6434260893942235, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2588956175598443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9e94ad99-4c13-4173-a92b-b7a2de0883ad", "name": "bce8dc23-2a13-447a-9cdb-1cd11f8da7d6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6abbf5df-fbd7-4a80-b490-df552d7a8b46"}}}]}, {"uuid": "fef89029-ffd0-4547-be17-2f8e25fd98c1", "name": "load_p1rlv53_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3c62646-6132-41ef-ba14-a06789885cd5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9e94ad99-4c13-4173-a92b-b7a2de0883ad"}}}}, {"uuid": "052c9588-be83-4b6d-b4e1-ce941bdc6797", "name": "6598428b-fe64-4bf0-b56b-cdda485c2999_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6434260893942235, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2588956175598443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7c9ba43e-b36b-4613-b5a1-25f468b059aa", "name": "d65071fc-6b69-4311-919e-214df90c62b4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "052c9588-be83-4b6d-b4e1-ce941bdc6797"}}}]}, {"uuid": "36946610-1dcc-4134-898b-141d86caebe6", "name": "load_p1rlv53_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3c62646-6132-41ef-ba14-a06789885cd5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7c9ba43e-b36b-4613-b5a1-25f468b059aa"}}}}, {"uuid": "cd4813cb-75e1-4fd1-995f-64aef6215ba9", "name": "9791f066-d559-48f2-8046-be65a4f4d83d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0716401691896973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6949594139700135, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "58b06842-060e-44f2-9f15-d2251967f3b2", "name": "c7e96f2d-342a-4a67-b4cc-f82c59ede79a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cd4813cb-75e1-4fd1-995f-64aef6215ba9"}}}]}, {"uuid": "56cd5e9f-8740-49f4-bb1e-5f4d8f19cfd7", "name": "load_p1rlv54_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20010301-32ce-4cc0-ab59-04ef3bcd35d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "58b06842-060e-44f2-9f15-d2251967f3b2"}}}}, {"uuid": "9c30dcb0-c947-4edc-accb-c0a02c230337", "name": "27a47eaa-eb7a-462e-9760-416f68e5ac5f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0716401691896973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6949594139700135, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6ec27cbf-3b73-4702-b082-dd7b3b1f2564", "name": "d40e052a-8972-4156-910d-04ea499fcc4e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9c30dcb0-c947-4edc-accb-c0a02c230337"}}}]}, {"uuid": "b6b82de1-3192-4c3e-9309-5d13723dfe0d", "name": "load_p1rlv54_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20010301-32ce-4cc0-ab59-04ef3bcd35d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6ec27cbf-3b73-4702-b082-dd7b3b1f2564"}}}}, {"uuid": "fa51dbf9-43bf-446a-9e23-9efce2fb5435", "name": "55e2003d-1b32-40de-8240-29a1f5add95d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3786182488338723, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5359363058124609, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "da3ee55b-aa13-409a-b48a-99c1ccbc9b50", "name": "ef778de1-7ba1-488d-b6e6-68ce6932d203", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fa51dbf9-43bf-446a-9e23-9efce2fb5435"}}}]}, {"uuid": "2f30ac26-a181-4f7c-8a9b-67ee9ead036d", "name": "load_p1rlv55_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36bdbc4e-edfa-425a-8e4c-e6123b567555"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "da3ee55b-aa13-409a-b48a-99c1ccbc9b50"}}}}, {"uuid": "312bc123-0043-4a03-a59d-87fdba87803e", "name": "03cfedd2-dd35-417e-97af-1239244ed228_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3786182488338723, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5359363058124609, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "273079c0-858a-4afc-842d-2db5866bcf6a", "name": "5f32ef60-0009-4b89-ab29-c49613ccf917", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "312bc123-0043-4a03-a59d-87fdba87803e"}}}]}, {"uuid": "487a0692-f420-4664-ba69-a3aaef52c74e", "name": "load_p1rlv55_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36bdbc4e-edfa-425a-8e4c-e6123b567555"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "273079c0-858a-4afc-842d-2db5866bcf6a"}}}}, {"uuid": "0b790946-d246-4c1b-b6d6-0067e4edf3e2", "name": "819ed8f1-a309-4e64-b58c-d80fd571d234_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b87f61d9-a337-4489-9654-b435a567edda", "name": "91ecacfa-eeb4-463b-a4b8-65ff42bbf590", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0b790946-d246-4c1b-b6d6-0067e4edf3e2"}}}]}, {"uuid": "a7ceae31-cc7f-49f5-a440-9c93041c8419", "name": "load_p1rlv56_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4694811a-ba43-4c78-b957-5209b1d961e2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b87f61d9-a337-4489-9654-b435a567edda"}}}}, {"uuid": "4997efb3-15ef-42ea-8a37-5a1d0d1aae2a", "name": "08d09627-4dd8-4c74-91ab-32d60227f297_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6f4634be-569c-45ec-a487-1965bfde5f15", "name": "83670ef5-637f-41d3-b84c-b45d9db70a0c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4997efb3-15ef-42ea-8a37-5a1d0d1aae2a"}}}]}, {"uuid": "070e0bec-c5d5-4935-a573-6a66c8208aff", "name": "load_p1rlv56_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4694811a-ba43-4c78-b957-5209b1d961e2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6f4634be-569c-45ec-a487-1965bfde5f15"}}}}, {"uuid": "ffa4dcab-7823-4f11-bf6a-11622e0b391d", "name": "82fe1b29-d541-46e7-b4b4-8e6e83de5da7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.511185229285174, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8722130080127372, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "31ac6afe-5d0b-494a-b26a-64cf8af68dc9", "name": "c4bda4a5-c91e-4fb1-b56f-ceac0da95f0a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ffa4dcab-7823-4f11-bf6a-11622e0b391d"}}}]}, {"uuid": "eca7e6a5-2e72-498f-98d6-4eca7a795e56", "name": "load_p1rlv57_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "925cb3b7-4ced-4a36-913f-e6851ed79b98"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "31ac6afe-5d0b-494a-b26a-64cf8af68dc9"}}}}, {"uuid": "8aa935a4-9605-4cb6-a05a-b8ebe51f985f", "name": "1126d6d6-6c31-495d-a583-9f93adb3930d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.511185229285174, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8722130080127372, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "804e20fc-ab81-4717-9429-66555387373a", "name": "8ee07f7d-15e5-4163-93f6-810e6c316b6f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8aa935a4-9605-4cb6-a05a-b8ebe51f985f"}}}]}, {"uuid": "1f3e6253-b8e5-4ab5-bdfd-46f9af4444d3", "name": "load_p1rlv57_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "925cb3b7-4ced-4a36-913f-e6851ed79b98"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "804e20fc-ab81-4717-9429-66555387373a"}}}}, {"uuid": "7bfa137b-d37c-442b-ae63-6721da62faca", "name": "3192da5c-462e-401a-ad0d-4ba86cbbac55_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "128dcbb1-a554-4a8c-a0ef-3f10fc6ece9a", "name": "6f48bd8b-c745-40a4-849d-120e366ef0a5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7bfa137b-d37c-442b-ae63-6721da62faca"}}}]}, {"uuid": "c6258ea2-4e94-495b-adcc-c27da8522fb8", "name": "load_p1rlv58_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a32ee184-f677-4333-b7ee-7bc30ab41467"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "128dcbb1-a554-4a8c-a0ef-3f10fc6ece9a"}}}}, {"uuid": "fbb74d60-d121-4c49-a358-66d3b15539f3", "name": "9777a21c-8520-4b8f-94ab-3a37c0672550_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b3f31c27-b8c8-496c-a1c1-6f526e6e4732", "name": "c6816637-b73c-498b-9c46-71c14dd403a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fbb74d60-d121-4c49-a358-66d3b15539f3"}}}]}, {"uuid": "96d1444f-c24b-41c0-89f4-083ac4adab31", "name": "load_p1rlv58_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a32ee184-f677-4333-b7ee-7bc30ab41467"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b3f31c27-b8c8-496c-a1c1-6f526e6e4732"}}}}, {"uuid": "e84d0660-066d-48bc-802c-5cbe6cac2b47", "name": "7ad86ff7-eac6-485e-9469-bb1107c41554_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8939358223380807, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6690937458929831, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "55fe9328-dfab-47ae-939b-f73d69f8ee61", "name": "5e2d0fd5-190f-4dca-90ea-7b395e67f368", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e84d0660-066d-48bc-802c-5cbe6cac2b47"}}}]}, {"uuid": "acf318a8-c7db-41ba-a49a-0d3705a9601e", "name": "load_p1rlv59_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b80bdb24-4bbf-4a57-bd5f-6a5ec9d484dd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "55fe9328-dfab-47ae-939b-f73d69f8ee61"}}}}, {"uuid": "07378ae1-451f-4351-85fa-e652d35d8dbd", "name": "3020cb8a-bacd-4e6c-b4dc-9d71e3b2a96f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8939358223380807, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6690937458929831, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4be7d08b-7d54-4074-9279-18ddfbf4b64d", "name": "944dac61-6bb8-4e25-b5b8-0ac042289404", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "07378ae1-451f-4351-85fa-e652d35d8dbd"}}}]}, {"uuid": "8156076c-aeb1-483e-8f62-90c96d0db843", "name": "load_p1rlv59_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b80bdb24-4bbf-4a57-bd5f-6a5ec9d484dd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4be7d08b-7d54-4074-9279-18ddfbf4b64d"}}}}, {"uuid": "9fd2f010-f617-43a1-90da-a2983bd347c4", "name": "899e1c08-546f-46cd-b858-30141d86191d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1603354468169496, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7593773040340845, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7ffe70a7-2162-4583-80f7-e23d5e9296ff", "name": "da86087f-0581-442c-ae58-fb5788a8094e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9fd2f010-f617-43a1-90da-a2983bd347c4"}}}]}, {"uuid": "40f63329-991b-4813-a3d9-3c0a33f74e01", "name": "load_p1rlv60_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7eb0d1e8-f85e-493e-b69b-26437fdb8ad9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7ffe70a7-2162-4583-80f7-e23d5e9296ff"}}}}, {"uuid": "dc057a50-c489-4f71-97d1-ad27dabaf0d4", "name": "feccd281-58a7-44c6-acad-281c415ca87d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1603354468169496, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7593773040340845, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d548187e-8179-4289-8ff0-3f449d1423ab", "name": "ffa07784-97a4-4bb1-aee9-d15a204eab67", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dc057a50-c489-4f71-97d1-ad27dabaf0d4"}}}]}, {"uuid": "59d7a530-4a41-4dca-a713-21c2102fdf1f", "name": "load_p1rlv60_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7eb0d1e8-f85e-493e-b69b-26437fdb8ad9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d548187e-8179-4289-8ff0-3f449d1423ab"}}}}, {"uuid": "ff35e51b-04ff-4f09-b482-99c27f5da1f3", "name": "f3126d12-75df-4d11-aa4a-a9c08cb9733f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9029063430901945, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8881818750925909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "329ffebf-7a8b-4470-ba34-ac91d74aa28b", "name": "2e847882-3c19-42d4-b0b9-2fdb6d848b33", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ff35e51b-04ff-4f09-b482-99c27f5da1f3"}}}]}, {"uuid": "c5b6c803-9bdd-4411-9f38-652d7968ea5a", "name": "load_p1rlv61_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d22bf2f5-74cc-47c7-ae3b-410fba27c113"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "329ffebf-7a8b-4470-ba34-ac91d74aa28b"}}}}, {"uuid": "8ce51ded-7745-44fc-9206-13f7b36d6891", "name": "3a2fdfa3-b04e-43f7-a3f9-18dc7f50dce9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9029063430901945, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8881818750925909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8210ad11-07f5-4373-9f5d-e77c22d9abef", "name": "c1260533-0133-42de-b91c-5b0f83659704", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ce51ded-7745-44fc-9206-13f7b36d6891"}}}]}, {"uuid": "578e25d2-3757-46ed-889a-360cc36ff3a2", "name": "load_p1rlv61_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d22bf2f5-74cc-47c7-ae3b-410fba27c113"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8210ad11-07f5-4373-9f5d-e77c22d9abef"}}}}, {"uuid": "3c87086a-2cd0-4d24-ab10-d38c58d4b720", "name": "76ddcb3d-8614-4e58-8f65-6f687775ca97_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4622944887503224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10483650830237357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5a347ad2-b6db-42a6-afdf-d1a8a92880b2", "name": "596a8497-bd49-420e-be09-72d24a3a98b7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3c87086a-2cd0-4d24-ab10-d38c58d4b720"}}}]}, {"uuid": "66875e4d-eb39-46ea-a39f-ee24343197db", "name": "load_p1rlv62_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "346dad85-3bf8-41a6-97ea-6b3b40a7f22e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5a347ad2-b6db-42a6-afdf-d1a8a92880b2"}}}}, {"uuid": "100071b2-0732-4f24-8a62-8be1cac1ccdf", "name": "6fdbc8d9-0d4c-4c6f-8661-8f6efc71b762_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4622944887503224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10483650830237357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "44334bee-647e-482e-b736-2ee9d2617deb", "name": "5338051a-88f9-4394-9b46-461b8ba3d191", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "100071b2-0732-4f24-8a62-8be1cac1ccdf"}}}]}, {"uuid": "04f417f8-f826-4bd9-b00e-01479da822d7", "name": "load_p1rlv62_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "346dad85-3bf8-41a6-97ea-6b3b40a7f22e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "44334bee-647e-482e-b736-2ee9d2617deb"}}}}, {"uuid": "8599c743-3264-4e27-b07b-8e70f18fc831", "name": "a4e57bc0-47f2-442e-916e-f28a36b42111_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7083181921938193, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5666922324635131, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "898bad6c-4120-423c-a19a-20da7d4feb01", "name": "5af4bc67-65a3-4da2-b651-b3acc3aef15f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8599c743-3264-4e27-b07b-8e70f18fc831"}}}]}, {"uuid": "78f2f1fb-da78-4ba9-9ad8-070d19f70556", "name": "load_p1rlv63_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8300f90c-9a3b-400d-af04-072125dce84f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "898bad6c-4120-423c-a19a-20da7d4feb01"}}}}, {"uuid": "01f9af62-6d2a-496a-bc8c-344e644cdf96", "name": "28c9d240-6539-4301-8c02-f9fdf480e77a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7083181921938193, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5666922324635131, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "86f365c8-5fb9-4b3e-b9de-50644f943c86", "name": "895b62dd-e0d9-407c-8610-7c3f92f4726a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "01f9af62-6d2a-496a-bc8c-344e644cdf96"}}}]}, {"uuid": "27a20244-06ca-45c4-9084-e1fcc1951a4c", "name": "load_p1rlv63_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8300f90c-9a3b-400d-af04-072125dce84f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "86f365c8-5fb9-4b3e-b9de-50644f943c86"}}}}, {"uuid": "b862f914-18e8-4f3f-a2ab-b4004b0a270c", "name": "c970302a-774f-49bf-b5e0-c2b30e2d230f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "07dab6b3-42a2-4c75-b6aa-e203b274546a", "name": "27d68dc6-3c92-412f-8cd5-96a426254f98", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b862f914-18e8-4f3f-a2ab-b4004b0a270c"}}}]}, {"uuid": "0ad073d3-f5f3-49ce-b085-f94653b6a7b8", "name": "load_p1rlv64_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5efd07ee-012a-40a4-97bb-07c1a5ed898c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "07dab6b3-42a2-4c75-b6aa-e203b274546a"}}}}, {"uuid": "3834f18a-3307-46e7-b128-2cb05ee29fdf", "name": "f42af146-ac7b-40bc-9d07-dc48db61df81_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "70b7f579-bc96-4d4f-8e5b-2676ad9989e2", "name": "35679726-0cd8-413c-9bb7-e7e069ee3ab3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3834f18a-3307-46e7-b128-2cb05ee29fdf"}}}]}, {"uuid": "62f41ebe-0ac1-445e-aa1c-f1b1ee6206c2", "name": "load_p1rlv64_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5efd07ee-012a-40a4-97bb-07c1a5ed898c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "70b7f579-bc96-4d4f-8e5b-2676ad9989e2"}}}}, {"uuid": "59222fb2-eed2-4531-886d-4ab391f26fd8", "name": "a4f53f0f-efda-4c30-9c32-c8d0501a6236_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.987999469244499, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42543082019456707, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aef24bb2-0143-4d23-b28f-76869b6f4d9d", "name": "def2e903-ba3c-4a94-a5f9-dc2fa49a6e46", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "59222fb2-eed2-4531-886d-4ab391f26fd8"}}}]}, {"uuid": "9efc84d7-f9d5-4795-8efd-d75517ccc450", "name": "load_p1rlv65_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e00fd9b-92b3-49c4-bcc2-957b9d2c7bad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aef24bb2-0143-4d23-b28f-76869b6f4d9d"}}}}, {"uuid": "ec001aa8-96b4-426f-ae24-a955358fb564", "name": "006c88d4-217f-4d52-b295-77ce7136abec_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.987999469244499, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42543082019456707, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5575b206-a4d9-4886-b943-6f83eb2da744", "name": "71eb4998-e8dc-46bd-983e-8f6ed559d229", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ec001aa8-96b4-426f-ae24-a955358fb564"}}}]}, {"uuid": "53fe26dd-75ad-46a7-ab2a-913f6a4efeb5", "name": "load_p1rlv65_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e00fd9b-92b3-49c4-bcc2-957b9d2c7bad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5575b206-a4d9-4886-b943-6f83eb2da744"}}}}, {"uuid": "afaef95b-19ae-4d4c-9bd7-29a86ae18b21", "name": "206317db-612b-4704-927f-fbf96927fc4e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4760012569901637, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5456626743322578, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "318e8349-3abc-4e20-b2d2-61184ad007af", "name": "12335a28-a671-4308-894b-a566e26d5169", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "afaef95b-19ae-4d4c-9bd7-29a86ae18b21"}}}]}, {"uuid": "601e7dc9-3f13-4d78-9de3-cac4d1420926", "name": "load_p1rlv66_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e90eb8a2-5db0-4861-96ef-a6991a0386eb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "318e8349-3abc-4e20-b2d2-61184ad007af"}}}}, {"uuid": "1ffcaa05-a532-4271-a582-0ef155917abf", "name": "98dda52b-a2a6-48d9-9ab8-0cb3f98c2c57_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4760012569901637, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5456626743322578, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c9ac0b1d-2a67-4235-b228-a001c83548de", "name": "51011efb-57db-45c9-b4c6-a38f0d590ca6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1ffcaa05-a532-4271-a582-0ef155917abf"}}}]}, {"uuid": "ca7d9648-ce04-409b-a2cb-3c41f2fd3466", "name": "load_p1rlv66_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e90eb8a2-5db0-4861-96ef-a6991a0386eb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c9ac0b1d-2a67-4235-b228-a001c83548de"}}}}, {"uuid": "01480de0-d6dc-4f77-b6fd-baec76795330", "name": "910685f4-8a79-4fb1-8e40-76a0dbc16746_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3018265224045242, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4135325648663858, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "48caeb22-cef1-44ce-8b7f-334baa96534a", "name": "deaf7d4c-d47c-456a-84d0-9426b6fa3647", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "01480de0-d6dc-4f77-b6fd-baec76795330"}}}]}, {"uuid": "56967678-ef97-4b84-8234-803c2743fc1d", "name": "load_p1rlv67_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64a67ed2-a563-4378-b6ac-d9a95339e862"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "48caeb22-cef1-44ce-8b7f-334baa96534a"}}}}, {"uuid": "b4172dd9-f9b8-41e5-99d2-3d6915d07d17", "name": "dc492572-240c-40df-9781-57f5e10675f7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3018265224045242, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4135325648663858, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0f4419de-9c75-4f53-8c77-250c21b8d5a6", "name": "22ea51f2-fbaa-46da-bb8e-d4317fbffd90", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b4172dd9-f9b8-41e5-99d2-3d6915d07d17"}}}]}, {"uuid": "fe5c82ba-f77a-4a58-b55b-703dbebd90a2", "name": "load_p1rlv67_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64a67ed2-a563-4378-b6ac-d9a95339e862"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0f4419de-9c75-4f53-8c77-250c21b8d5a6"}}}}, {"uuid": "7ada4d37-f4d3-40ed-9acd-d5faba481be4", "name": "e25d5b2a-2237-4c29-8fe4-17b6a3691be9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0137187800791063, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5284248988065299, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "543d61c1-6beb-4d3f-ad74-6ac05c55b839", "name": "585ee9d5-3a0b-4e15-af3a-7f3d401331c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7ada4d37-f4d3-40ed-9acd-d5faba481be4"}}}]}, {"uuid": "349f2751-aa29-4c04-984e-19e73fec0a3e", "name": "load_p1rlv68_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c22aa2c8-a6fc-4b27-a875-e07e3f50ecac"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "543d61c1-6beb-4d3f-ad74-6ac05c55b839"}}}}, {"uuid": "2b5d429b-3513-498e-95c9-5e9dcf8f77f7", "name": "13fb1350-2b2d-47f8-94b4-f87982450d96_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0137187800791063, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5284248988065299, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eacc52d2-bcce-4dcc-b6fa-08595047ae7b", "name": "246247a2-c496-41cf-88df-973e7f0884ee", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2b5d429b-3513-498e-95c9-5e9dcf8f77f7"}}}]}, {"uuid": "bc8c3905-1e5c-4811-9bfd-9689ad2d7792", "name": "load_p1rlv68_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c22aa2c8-a6fc-4b27-a875-e07e3f50ecac"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eacc52d2-bcce-4dcc-b6fa-08595047ae7b"}}}}, {"uuid": "fdb23bcf-6111-45ce-ba6c-9007569fce0e", "name": "3808ebb1-face-4a6e-ac7a-7c748c7b669e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7457942211533133, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8784341351558463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b97a3dfb-cc9f-4973-ba82-2213198cebe0", "name": "6768ceee-43be-427e-942b-0db671a29204", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fdb23bcf-6111-45ce-ba6c-9007569fce0e"}}}]}, {"uuid": "efaa2824-5c5f-4090-a1d0-e423cd416f50", "name": "load_p1rlv69_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "876ffb0b-f33c-45b2-a085-7b34103ecffc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b97a3dfb-cc9f-4973-ba82-2213198cebe0"}}}}, {"uuid": "4bc44e80-80e4-4ce6-ac5f-0c25e7ec3613", "name": "34f1e2e2-5b8c-4c0c-bff0-c252aa0692cb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7457942211533133, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8784341351558463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7c06383e-92cc-4e56-819a-5e3f04c47953", "name": "851c42dc-9eee-420a-b9f2-c2aaf0f5858d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4bc44e80-80e4-4ce6-ac5f-0c25e7ec3613"}}}]}, {"uuid": "4e205fd5-defb-40c6-9ee3-9503b82895d3", "name": "load_p1rlv69_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "876ffb0b-f33c-45b2-a085-7b34103ecffc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7c06383e-92cc-4e56-819a-5e3f04c47953"}}}}, {"uuid": "9318faf6-43f3-4b64-b795-832075723229", "name": "db559aeb-98cf-423d-a41a-7164ba97f874_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9024769844937937, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4778358547008617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eba25c14-7d83-4638-8dd7-0112ebd2975b", "name": "1b4e6b62-4c77-4826-a67a-a1f3ff117cd5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9318faf6-43f3-4b64-b795-832075723229"}}}]}, {"uuid": "b67279ba-f49e-43db-945d-e40605cabca3", "name": "load_p1rlv70_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e53e7714-06d1-4f85-89c5-f152629e8ab7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eba25c14-7d83-4638-8dd7-0112ebd2975b"}}}}, {"uuid": "051edfd9-73cd-4d9e-b201-66ecec1ba31a", "name": "23733246-02ee-4dbb-81e6-1328a944508e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9024769844937937, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4778358547008617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f696d473-ce5b-47cc-b65b-283c16067c2a", "name": "b6029e0d-b18c-45df-bae2-892a50823b72", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "051edfd9-73cd-4d9e-b201-66ecec1ba31a"}}}]}, {"uuid": "aa5c61af-18a1-453f-a3f4-a01a6ff35a85", "name": "load_p1rlv70_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e53e7714-06d1-4f85-89c5-f152629e8ab7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f696d473-ce5b-47cc-b65b-283c16067c2a"}}}}, {"uuid": "a5d6224c-b3d0-431d-9687-6aee701eed15", "name": "dcae4974-9e3e-475f-a5f0-c032a786fb75_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.67620786252276, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6753067705079763, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e8511645-a7d1-4737-8cc2-82d08e7818e6", "name": "437ee150-f220-427c-b24f-f817c64d804c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a5d6224c-b3d0-431d-9687-6aee701eed15"}}}]}, {"uuid": "753210c9-2537-407d-8134-f6994ae34c0f", "name": "load_p1rlv71_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d7791de-0cf6-4901-8b95-2d67870f09f5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e8511645-a7d1-4737-8cc2-82d08e7818e6"}}}}, {"uuid": "932477c7-093b-4a62-a26c-00c103b7afb4", "name": "c0c3200b-1955-40cd-a5ec-d8b3427fb9e7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.67620786252276, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6753067705079763, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1979701e-0c8f-4afd-82d1-72025b72e5b5", "name": "8fc03c47-5d22-4a89-ab4e-017f7f49625f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "932477c7-093b-4a62-a26c-00c103b7afb4"}}}]}, {"uuid": "f1e0849b-033d-4707-a5da-2f479ad9b242", "name": "load_p1rlv71_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d7791de-0cf6-4901-8b95-2d67870f09f5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1979701e-0c8f-4afd-82d1-72025b72e5b5"}}}}, {"uuid": "171f09a9-7d92-4ebd-bc33-a8ce323d7740", "name": "601db640-ac9c-4700-8e3d-ce9c23046380_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7083181921938193, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5666922324635131, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "64770796-9427-46e0-87b6-dba6df0d845f", "name": "0b8bba1b-3692-4a6b-9087-cacf89b0b8c6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "171f09a9-7d92-4ebd-bc33-a8ce323d7740"}}}]}, {"uuid": "73bd524a-2a7b-4850-9219-476e289e193a", "name": "load_p1rlv72_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc710fc3-ae5f-478e-997b-85467db7c93c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "64770796-9427-46e0-87b6-dba6df0d845f"}}}}, {"uuid": "18482ac3-1e93-4767-965b-b1551c7ec390", "name": "17d289a0-09c1-4ba9-8024-35bf760e95dd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7083181921938193, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5666922324635131, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e2005fa8-788f-49f4-a6fc-2a3fcb0789b1", "name": "30d7102e-5d90-496d-b7b2-5d74ecb4c561", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "18482ac3-1e93-4767-965b-b1551c7ec390"}}}]}, {"uuid": "2f4bbdec-435b-4b1c-b766-2dc3fd9d6b0b", "name": "load_p1rlv72_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc710fc3-ae5f-478e-997b-85467db7c93c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e2005fa8-788f-49f4-a6fc-2a3fcb0789b1"}}}}, {"uuid": "95a44352-4c4c-4538-a12b-b845882ef1b0", "name": "5dfa04b0-3d87-4fcf-89d3-d2d88f53864c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9051339071763382, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34139556761684264, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c1da838c-955a-49f5-96d2-5b319c046b1b", "name": "6cb71f3e-84ab-4eb1-8d64-e94b484e234f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "95a44352-4c4c-4538-a12b-b845882ef1b0"}}}]}, {"uuid": "72d6dc0d-dbd3-4ed7-99c7-a9079120b408", "name": "load_p1rlv73_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4e2991c-1404-44da-bbb5-5a2ebc43bde4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c1da838c-955a-49f5-96d2-5b319c046b1b"}}}}, {"uuid": "09f3f48f-ccec-44e7-945e-17e6b940dae3", "name": "637008f6-2fb8-4ce9-b3c3-4d5fdb03370d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9051339071763382, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34139556761684264, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8dad0dd4-67e1-45e0-8d3f-29b4204c8f7a", "name": "ba48f13c-9b3f-4f92-bf0f-c05e4b1713f8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "09f3f48f-ccec-44e7-945e-17e6b940dae3"}}}]}, {"uuid": "2c9f38cb-dd0e-47c2-8989-5b42a798d63b", "name": "load_p1rlv73_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4e2991c-1404-44da-bbb5-5a2ebc43bde4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8dad0dd4-67e1-45e0-8d3f-29b4204c8f7a"}}}}, {"uuid": "aced7483-5ca3-4fe3-9a80-7ad42326f6b3", "name": "eeff11e3-ccc5-4d5b-8432-d16b4d08dda8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.4509454152189125, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9978822313633423, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1066ce43-8f62-4734-b2f1-0d2d4e925c63", "name": "e1e3028b-662a-4460-aee6-532ec71815f3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aced7483-5ca3-4fe3-9a80-7ad42326f6b3"}}}]}, {"uuid": "79acc9d8-71a7-41c0-a471-9d9f27e2d3fc", "name": "load_p1rlv74_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5861410e-9d6d-423e-b967-2f2af65610b8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1066ce43-8f62-4734-b2f1-0d2d4e925c63"}}}}, {"uuid": "60451775-92b6-4bf4-9f2c-5448fe20d483", "name": "6d5fcafa-ab52-4b90-a0e2-edcb0734040a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.4509454152189125, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9978822313633423, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "343a81e9-b88c-4f56-8722-4252ebf06a78", "name": "07205db1-1d6a-4850-8bd6-bca3b295fa0e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "60451775-92b6-4bf4-9f2c-5448fe20d483"}}}]}, {"uuid": "dad038de-44f9-459a-bb66-d26063065fe2", "name": "load_p1rlv74_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5861410e-9d6d-423e-b967-2f2af65610b8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "343a81e9-b88c-4f56-8722-4252ebf06a78"}}}}, {"uuid": "e6727a08-79b7-4316-b1fb-92835a5f95c5", "name": "2ead64c7-e386-418d-8808-33609a3ceda3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6211116916449642, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3778136238343289, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8e88cc6c-66b8-49cf-a605-634760d875b6", "name": "d71f38b7-e1be-4217-bdd4-9bf759822e90", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e6727a08-79b7-4316-b1fb-92835a5f95c5"}}}]}, {"uuid": "bd3d2042-a713-4793-9d03-bf8942a59c48", "name": "load_p1rlv75_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ef51371-3fa2-400a-a2b4-3afa97ff2419"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8e88cc6c-66b8-49cf-a605-634760d875b6"}}}}, {"uuid": "7b61b33f-2010-4907-8271-5ff87054e074", "name": "1e148a6c-faa9-4a61-950f-6fd0b951acd4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6211116916449642, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3778136238343289, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "008bf0e6-0413-4467-8e83-1c8f960b4d47", "name": "99b717d0-dd73-4623-a3ab-281f3b99990e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b61b33f-2010-4907-8271-5ff87054e074"}}}]}, {"uuid": "cf336d44-81c4-4f45-81a3-dd94dada5711", "name": "load_p1rlv75_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ef51371-3fa2-400a-a2b4-3afa97ff2419"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "008bf0e6-0413-4467-8e83-1c8f960b4d47"}}}}, {"uuid": "401ab11c-c2ca-4af5-83c5-07c0363178e9", "name": "29ee0be8-831d-4de6-9384-3a20b0130b9b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9972586284721718, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5405993695804993, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8aa83d12-59f5-4bd1-9bab-eb86f3b8f9cd", "name": "49ad30de-c56a-46fa-b952-3da284311066", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "401ab11c-c2ca-4af5-83c5-07c0363178e9"}}}]}, {"uuid": "86acebf5-6adf-437e-bb88-4355e0a18752", "name": "load_p1rlv76_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3354497f-6de7-405d-9fca-a9c77463dc27"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8aa83d12-59f5-4bd1-9bab-eb86f3b8f9cd"}}}}, {"uuid": "a2bc55db-41cc-4697-9041-f6afcc88f075", "name": "5192ad56-41bf-4e17-ba69-df91196fded9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9972586284721718, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5405993695804993, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "212c4d7c-ce43-4ee7-99ea-d311eeb73f6b", "name": "46651f50-b9b3-4d1a-ab92-766edd5c0ea7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a2bc55db-41cc-4697-9041-f6afcc88f075"}}}]}, {"uuid": "829a24fa-03e0-4bb7-85bd-18af6a600c59", "name": "load_p1rlv76_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3354497f-6de7-405d-9fca-a9c77463dc27"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "212c4d7c-ce43-4ee7-99ea-d311eeb73f6b"}}}}, {"uuid": "907cd593-47d9-414c-9363-fc74d801bac8", "name": "5670f2ba-5ba8-4ff2-ac56-2b3074e6c8bc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5906266465914705, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5909884959248153, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "242af08d-0057-4a60-ad70-584db34fe2da", "name": "3bffc9ae-98d9-4564-a1d7-a2043f167347", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "907cd593-47d9-414c-9363-fc74d801bac8"}}}]}, {"uuid": "5b1e63c2-8a7f-49e8-81b4-33c812d96e66", "name": "load_p1rlv77_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f88a22a3-7e6c-4fc5-a8f4-a08cdaa3f5d6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "242af08d-0057-4a60-ad70-584db34fe2da"}}}}, {"uuid": "6c51c685-cd8d-428b-961a-6e577b49da69", "name": "c153e376-cd37-4afd-a4f0-44059fb3bd42_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5906266465914705, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5909884959248153, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f034abf0-9bf2-432b-9076-d81d579ab322", "name": "87ae233a-d756-446d-b7c6-f68f6b8809a8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c51c685-cd8d-428b-961a-6e577b49da69"}}}]}, {"uuid": "863be99e-0075-4534-ac07-5c38053fd75f", "name": "load_p1rlv77_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f88a22a3-7e6c-4fc5-a8f4-a08cdaa3f5d6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f034abf0-9bf2-432b-9076-d81d579ab322"}}}}, {"uuid": "e00ae0f3-c833-4c32-bc1b-62e2800b2ae3", "name": "54b10842-69f3-44d3-983a-1e05f6d6847e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.307297155025492, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20108954410245963, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "49074f23-3cec-4e91-8619-29b4df38c43f", "name": "954509de-44bf-4a2f-adb7-3266478e3ce0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e00ae0f3-c833-4c32-bc1b-62e2800b2ae3"}}}]}, {"uuid": "7ccb5eb7-4b8e-4d08-ba79-67b2d36c0e28", "name": "load_p1rlv78_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae76f058-b79a-4c0f-90be-f9cd7a02bcfc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "49074f23-3cec-4e91-8619-29b4df38c43f"}}}}, {"uuid": "513edbe7-9f8a-47e7-b306-d5ee792f8316", "name": "3fd72f79-30f1-4872-b8ce-b5bf993ace92_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.307297155025492, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20108954410245963, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "67d51062-6006-4e4b-870e-daf7b42dd301", "name": "25a078b4-10c4-4992-ab76-c8d1267af0e8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "513edbe7-9f8a-47e7-b306-d5ee792f8316"}}}]}, {"uuid": "01058f72-29ef-4ad0-ac3b-29577e185af8", "name": "load_p1rlv78_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae76f058-b79a-4c0f-90be-f9cd7a02bcfc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "67d51062-6006-4e4b-870e-daf7b42dd301"}}}}, {"uuid": "f6a96aff-44b9-4310-8cec-c6c2b14b33a8", "name": "b7379432-13b6-4763-a2ca-4bbfbad3f8fb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3315344999322854, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13574204648198762, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1d093d27-94a2-420f-9153-e4364aa561fe", "name": "bdb6170b-c44d-4582-8da9-2ce5e6b2894e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f6a96aff-44b9-4310-8cec-c6c2b14b33a8"}}}]}, {"uuid": "c2d61fb1-e7cb-4984-9dd4-61311694f5ff", "name": "load_p1rlv79_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4dd2283-6100-48ce-b4bc-0e37b7b4e409"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1d093d27-94a2-420f-9153-e4364aa561fe"}}}}, {"uuid": "7e58475c-002a-4f30-8c93-c7f602f794bf", "name": "af5fd900-aa6b-47ea-8c41-bcdfb62950b1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3315344999322854, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13574204648198762, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "678e4c04-ef44-4a06-ad06-ecd15fc903b3", "name": "45d74966-1781-49fc-9ee4-83e8c62a0e43", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7e58475c-002a-4f30-8c93-c7f602f794bf"}}}]}, {"uuid": "90b6d2ad-8447-41d3-8410-66bc45c0a8c4", "name": "load_p1rlv79_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4dd2283-6100-48ce-b4bc-0e37b7b4e409"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "678e4c04-ef44-4a06-ad06-ecd15fc903b3"}}}}, {"uuid": "8e73e272-ff08-4f45-ba2f-09fc3e5a8fa5", "name": "8c8ae855-b307-4833-a21c-c40bc511bc49_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.949137985829372, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.575540256876006, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6bea2e1f-72c3-4820-ab6e-e50a770156b9", "name": "289ae79d-4446-4fa2-afb5-8bda2d97054e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8e73e272-ff08-4f45-ba2f-09fc3e5a8fa5"}}}]}, {"uuid": "36240d9c-fa6e-4e7c-8806-54998ae16ba6", "name": "load_p1rlv80_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab7e1b4a-f8ec-4211-b7a0-d7f9057f576a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6bea2e1f-72c3-4820-ab6e-e50a770156b9"}}}}, {"uuid": "56d0a40d-1c01-4253-bd49-17a4ff33393f", "name": "6bde1f81-0fb4-4d6c-bcb2-37ff2712533a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.949137985829372, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.575540256876006, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8c2651f3-50f5-46e6-9e5f-1325b9300ce7", "name": "3a1244f7-b0f9-41df-9551-4a5222d91c23", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "56d0a40d-1c01-4253-bd49-17a4ff33393f"}}}]}, {"uuid": "9f53e5b8-cc13-4f88-8d06-dbf7d9f9250d", "name": "load_p1rlv80_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab7e1b4a-f8ec-4211-b7a0-d7f9057f576a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8c2651f3-50f5-46e6-9e5f-1325b9300ce7"}}}}, {"uuid": "dacbc3fd-e8fc-41e1-979a-f31318a804a7", "name": "1216a7da-abd7-4d65-893a-79470bfa76d5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.94390101914808, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4734308884348923, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "64d85114-19cb-4b9c-87b4-d99dd2964eb7", "name": "3aebcaa7-c27a-4c99-9dd4-d9ff99542bf0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dacbc3fd-e8fc-41e1-979a-f31318a804a7"}}}]}, {"uuid": "9b5ab49d-17fc-4a4b-824e-c2fd0dc8bc23", "name": "load_p1rlv81_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef92e40c-fe3c-4f7f-b844-884e1079e491"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "64d85114-19cb-4b9c-87b4-d99dd2964eb7"}}}}, {"uuid": "da745182-9985-4a61-8f4e-b5de2ad03235", "name": "46efe056-862e-4385-a344-c132c8299364_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.94390101914808, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4734308884348923, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ee387653-80e7-474e-846c-81b5f5b6a6d2", "name": "26c2ebf2-3c81-4891-8188-e08d41dd10a8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "da745182-9985-4a61-8f4e-b5de2ad03235"}}}]}, {"uuid": "f89298d2-b950-41d4-8276-101df4186a6e", "name": "load_p1rlv81_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef92e40c-fe3c-4f7f-b844-884e1079e491"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ee387653-80e7-474e-846c-81b5f5b6a6d2"}}}}, {"uuid": "af5a52a2-3fe9-4359-93fd-d55143549a28", "name": "1d6d2c06-1203-4968-ac98-b4d4ac8dc5b7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8534881847076217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.812795269620709, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "38eab04b-b674-49e4-bc32-07f6e0824eab", "name": "4e16fa12-982b-48ad-a47a-f250918d5af4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "af5a52a2-3fe9-4359-93fd-d55143549a28"}}}]}, {"uuid": "a62a54a5-6697-443b-a32b-361d4df7db89", "name": "load_p1rlv82_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3ddd704-2530-4392-8e9e-06e047b12f41"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "38eab04b-b674-49e4-bc32-07f6e0824eab"}}}}, {"uuid": "58a22351-641e-471f-8761-366370ea2434", "name": "c93e98c4-b94c-4d47-ae80-bd03cfe25cb2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8534881847076217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.812795269620709, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6fc40c4f-722e-4b46-a59a-49a12373a9cb", "name": "97c7b1a9-89fd-4b27-a3af-81893c03fdeb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58a22351-641e-471f-8761-366370ea2434"}}}]}, {"uuid": "8859a756-2afb-4ba2-b94c-856c2e66a892", "name": "load_p1rlv82_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3ddd704-2530-4392-8e9e-06e047b12f41"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6fc40c4f-722e-4b46-a59a-49a12373a9cb"}}}}, {"uuid": "6bd10507-5bba-4bd0-bef6-a72f290a6b67", "name": "6f2028c5-16e7-4328-8e03-13bf0033686e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.67620786252276, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6753067705079763, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b953ab0d-ba0c-4318-a252-6adef9567579", "name": "f4a2ebc7-287c-4c3b-a6f6-f3ce4a3586f1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6bd10507-5bba-4bd0-bef6-a72f290a6b67"}}}]}, {"uuid": "7665a9b0-76d2-400a-96c0-6f0990926a37", "name": "load_p1rlv83_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24c3e8d8-1520-4a05-84af-a70da6140b4d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b953ab0d-ba0c-4318-a252-6adef9567579"}}}}, {"uuid": "f70363eb-715d-40c7-a5fc-d7a56e04daf3", "name": "ef0c837c-6f9d-47a1-b498-882f08d091ce_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.67620786252276, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6753067705079763, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "78a15a68-4494-4c64-a4d8-7922e66e8997", "name": "f00b83e2-3f0d-4136-bbee-68ce5e3fc5c8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f70363eb-715d-40c7-a5fc-d7a56e04daf3"}}}]}, {"uuid": "88b75824-d49f-4113-a8c6-40ab676f6052", "name": "load_p1rlv83_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24c3e8d8-1520-4a05-84af-a70da6140b4d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "78a15a68-4494-4c64-a4d8-7922e66e8997"}}}}, {"uuid": "ad189afa-a8cc-4feb-aac9-4d99560096bb", "name": "e8272f62-d3e6-4e83-875d-129826f5a230_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2851011950034972, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5829386425893015, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "acd82457-1844-4bec-8ac5-5a37bf06e070", "name": "0374fa7b-d2bf-45ee-b82d-3ce35d0efd09", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ad189afa-a8cc-4feb-aac9-4d99560096bb"}}}]}, {"uuid": "051b254a-b970-418d-92f0-2373c3f21681", "name": "load_p1rlv84_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "55e7538f-4bde-4810-a237-ac0cad7ba805"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "acd82457-1844-4bec-8ac5-5a37bf06e070"}}}}, {"uuid": "1b337f5d-481e-47a9-94e2-6c18b30933c2", "name": "54310b84-29a0-4191-990c-fc85dcf39f15_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2851011950034972, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5829386425893015, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fb46c6ba-5700-4c6f-9aca-52a6c4a67e00", "name": "ad3546ac-85e1-4a6a-be55-77848057669d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1b337f5d-481e-47a9-94e2-6c18b30933c2"}}}]}, {"uuid": "11d28132-44eb-4000-b730-9f6b60fb5574", "name": "load_p1rlv84_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "55e7538f-4bde-4810-a237-ac0cad7ba805"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fb46c6ba-5700-4c6f-9aca-52a6c4a67e00"}}}}, {"uuid": "8ea51f72-6007-45f2-934c-ee720a2a2a6d", "name": "e93d34db-209b-410b-99e8-74e2a10f1f24_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.904546554088597, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7711735109904765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ccf23164-9fe3-498a-8339-0cd4afaaac3b", "name": "34eb3b6c-c8a2-40b9-b54c-561072b6b44d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ea51f72-6007-45f2-934c-ee720a2a2a6d"}}}]}, {"uuid": "23d33e7c-c398-44ea-9d3b-24dfc98d40c8", "name": "load_p1rlv85_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcc52dd9-bacb-4e49-a057-d3747f89a7f7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ccf23164-9fe3-498a-8339-0cd4afaaac3b"}}}}, {"uuid": "55918753-a6a5-4ae9-a332-7fe46c0295e7", "name": "d5657e75-94e2-4bd5-9b06-70f7046f60c4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.904546554088597, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7711735109904765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7069ce04-1c39-41c2-be08-6a3ca23bbda5", "name": "a581fb52-0345-443c-8a00-55901ea16962", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "55918753-a6a5-4ae9-a332-7fe46c0295e7"}}}]}, {"uuid": "c4dba301-7f1a-4f27-a876-cf8834058be0", "name": "load_p1rlv85_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcc52dd9-bacb-4e49-a057-d3747f89a7f7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7069ce04-1c39-41c2-be08-6a3ca23bbda5"}}}}, {"uuid": "35c623f4-72bb-454f-917f-134d2d188e73", "name": "b7492d0b-7810-4e67-b9ff-6ba1915425df_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8309189378455104, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6069744647018672, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c1b59f56-d91c-4edc-bdb4-5b6d88df2d73", "name": "17d3e626-6bd6-420f-b575-cfec57187186", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "35c623f4-72bb-454f-917f-134d2d188e73"}}}]}, {"uuid": "78febb96-7b66-4d6e-941a-633a0723f10e", "name": "load_p1rlv86_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "540e0121-fc39-4c2c-9fbc-012c020f5994"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c1b59f56-d91c-4edc-bdb4-5b6d88df2d73"}}}}, {"uuid": "cb5d3869-1d7a-4b61-85bd-8d1a5aa2b9dd", "name": "93bb007f-267b-4671-9657-383b7126fe63_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8309189378455104, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6069744647018672, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e4bbaed5-dcd9-4e1e-868b-1af88726dd4e", "name": "175acd64-2275-44e6-bd26-30a79b5a1ec6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cb5d3869-1d7a-4b61-85bd-8d1a5aa2b9dd"}}}]}, {"uuid": "9b25e5dd-b353-4e2b-bdd0-8b2f40cc299b", "name": "load_p1rlv86_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "540e0121-fc39-4c2c-9fbc-012c020f5994"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e4bbaed5-dcd9-4e1e-868b-1af88726dd4e"}}}}, {"uuid": "f8606531-663e-47cf-8178-789276058169", "name": "6ab123dc-6c35-4df5-8209-24b8745916dd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6155541211188646, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3901757582026717, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7c78dccd-a904-40f6-aae0-535fd349386c", "name": "d096316e-5678-4fdc-96ea-49e7e048da3b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8606531-663e-47cf-8178-789276058169"}}}]}, {"uuid": "20f2b601-a6da-407d-9ddf-87c50e403dec", "name": "load_p1rlv87_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "46ee0e6c-daf7-4412-94a7-5332a6a97656"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7c78dccd-a904-40f6-aae0-535fd349386c"}}}}, {"uuid": "9b3e1397-1275-46d9-9b9a-44746c91dd20", "name": "258bad8c-9602-4318-9c3c-e2a3e4e2e011_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6155541211188646, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3901757582026717, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3b78c1ee-1cbb-4069-aec6-ee865c5810cf", "name": "fc6c0202-3e9d-4df9-840e-d229a3b85917", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9b3e1397-1275-46d9-9b9a-44746c91dd20"}}}]}, {"uuid": "3be5a22a-d467-4a98-a15c-ee8144f64ffa", "name": "load_p1rlv87_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "46ee0e6c-daf7-4412-94a7-5332a6a97656"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3b78c1ee-1cbb-4069-aec6-ee865c5810cf"}}}}, {"uuid": "98718c72-49ed-4f8b-94f4-4486786a2f17", "name": "8d2cd1f7-4c5f-4548-8f39-8c21701f2f80_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3439175585507637, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8866404836608991, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a834a5c7-98fd-4c36-a1a2-117df752ee7d", "name": "66056a6c-7515-44a0-8fe2-220d35df50b5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "98718c72-49ed-4f8b-94f4-4486786a2f17"}}}]}, {"uuid": "31a2910b-97f0-435f-8446-edb59ff49f20", "name": "load_p1rlv88_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "188047cd-3f14-4240-91fe-30113d48152b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a834a5c7-98fd-4c36-a1a2-117df752ee7d"}}}}, {"uuid": "2205e2f6-a33f-480b-871b-dff81b6dfe6f", "name": "74a63789-fa7d-45df-9e5f-00cf98af8d57_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3439175585507637, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8866404836608991, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "811f21d5-64e0-4d1f-aa87-f48fe0c030be", "name": "22c86dd0-3ef8-43a5-a22d-be5e7a8838b3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2205e2f6-a33f-480b-871b-dff81b6dfe6f"}}}]}, {"uuid": "13edc7c2-1815-4ec8-864b-37a1be4f09ed", "name": "load_p1rlv88_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "188047cd-3f14-4240-91fe-30113d48152b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "811f21d5-64e0-4d1f-aa87-f48fe0c030be"}}}}, {"uuid": "58590f5d-13ba-4b38-bd02-39cb9b23f78c", "name": "e9546252-1b58-4899-9c11-7318389954bc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.872515319591797, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7328111219910317, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "84b98861-33f5-4f04-a307-ce744f52b0a2", "name": "324e5a11-5970-42e7-b780-a2a7a153e909", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58590f5d-13ba-4b38-bd02-39cb9b23f78c"}}}]}, {"uuid": "9df16e4f-d791-4919-8ac9-6fa71869a7f6", "name": "load_p1rlv89_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24d75e9a-0249-48ca-ad10-32738bb6a519"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "84b98861-33f5-4f04-a307-ce744f52b0a2"}}}}, {"uuid": "4411040a-b8aa-4292-8c6f-6b01cd8a0937", "name": "0215f688-785c-42bb-9301-214b3f14d55b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.872515319591797, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7328111219910317, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d71ed8bc-50f6-4a34-bd20-821b33cb7331", "name": "d6b371e7-a88d-4ac8-90bc-da731158d936", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4411040a-b8aa-4292-8c6f-6b01cd8a0937"}}}]}, {"uuid": "68f4c66d-4cd7-49d8-bf03-0e936b39cc47", "name": "load_p1rlv89_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24d75e9a-0249-48ca-ad10-32738bb6a519"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d71ed8bc-50f6-4a34-bd20-821b33cb7331"}}}}, {"uuid": "f0818f91-427a-4dac-859a-9db5b784179b", "name": "606a83fe-20ef-45bd-92c5-f5146a296b44_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6767459289154356, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5300288174067083, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4e5f0c53-8b54-448d-a458-e7d628e7e647", "name": "7d1c415d-e8dc-4012-ba79-b478fef95e10", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f0818f91-427a-4dac-859a-9db5b784179b"}}}]}, {"uuid": "2938636d-de76-44c7-8bae-5ca12ea547e5", "name": "load_p1rlv90_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e06b2ac7-926e-4caf-afac-386910d4ea5e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4e5f0c53-8b54-448d-a458-e7d628e7e647"}}}}, {"uuid": "737e66f7-4b97-4feb-9812-0697f1b837ea", "name": "98a76c71-fc18-4ba7-aaae-ffd2f60dbabf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6767459289154356, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5300288174067083, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "383a78a2-9fcc-402b-a8c8-d9401b3d9bc1", "name": "5bdef5f2-0868-4b5e-8d9b-45781ef23db4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "737e66f7-4b97-4feb-9812-0697f1b837ea"}}}]}, {"uuid": "4e1fefc7-4df0-49fd-9047-d74b8256fd10", "name": "load_p1rlv90_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e06b2ac7-926e-4caf-afac-386910d4ea5e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "383a78a2-9fcc-402b-a8c8-d9401b3d9bc1"}}}}, {"uuid": "18090cd0-1050-4ea4-9081-1b5987f13ed5", "name": "859d3065-e984-44a5-80da-e2ac323cea76_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.089287670026504, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22715368737478026, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dd1b2f42-bfb0-4733-be1f-244a6f9aff0f", "name": "904dc742-32db-4a73-a9b3-ec2156ab46bf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "18090cd0-1050-4ea4-9081-1b5987f13ed5"}}}]}, {"uuid": "99780ee0-abf9-4307-b4e4-ed14d98ebf73", "name": "load_p1rlv91_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a1f01bc-d1f1-4d92-b1e2-1f8223624c52"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dd1b2f42-bfb0-4733-be1f-244a6f9aff0f"}}}}, {"uuid": "fb746a89-e5d8-407e-983a-f03e98d40634", "name": "b0033884-40dc-422f-a2ca-e44dfe1edc9f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.089287670026504, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22715368737478026, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "29c942c6-c2bb-4192-9690-6d377bdf7fa1", "name": "43d21665-1ce2-4376-aa4a-c9603e1290cd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fb746a89-e5d8-407e-983a-f03e98d40634"}}}]}, {"uuid": "9f5996d0-70d0-46af-a97f-981b46824f37", "name": "load_p1rlv91_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a1f01bc-d1f1-4d92-b1e2-1f8223624c52"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "29c942c6-c2bb-4192-9690-6d377bdf7fa1"}}}}, {"uuid": "fe1ba8b5-2e95-43ff-a991-580ba9a4d8e8", "name": "6159d973-f677-4323-8366-eed9b570ef52_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.298373512871933, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.08780226018253445, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6ddbae49-7bba-48e9-b129-7c86cceadc16", "name": "4afa950b-0abb-4e3f-8041-4d9ee05e086c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fe1ba8b5-2e95-43ff-a991-580ba9a4d8e8"}}}]}, {"uuid": "6e7fa03a-2160-4bc3-9a4f-cc003402162c", "name": "load_p1rlv92_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db8f484a-94d5-4d20-8ebf-6708b1601a0d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6ddbae49-7bba-48e9-b129-7c86cceadc16"}}}}, {"uuid": "f8b727ed-1984-40fc-9771-1efd1d55309f", "name": "bd82d5a0-503b-4b3c-b694-64730b273252_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.298373512871933, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.08780226018253445, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5bd4562a-8138-450e-a625-2848c9a1501a", "name": "75349981-2801-4269-9d4f-7e93fd11a841", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8b727ed-1984-40fc-9771-1efd1d55309f"}}}]}, {"uuid": "614d03f1-10f5-420d-b6f1-ae9627c6077f", "name": "load_p1rlv92_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db8f484a-94d5-4d20-8ebf-6708b1601a0d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5bd4562a-8138-450e-a625-2848c9a1501a"}}}}, {"uuid": "acc5f822-9896-4ed6-b7f9-961c04a79fcf", "name": "2d5e9b56-2043-4d51-b09f-0eae337cba7c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1206689642843692, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34257205075767067, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a5557f1-421f-4b7b-928f-124c33d795b9", "name": "3c2684f6-00a4-4532-85da-7a965986254c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "acc5f822-9896-4ed6-b7f9-961c04a79fcf"}}}]}, {"uuid": "c54cefdf-63d6-4bcf-bfae-bcfa3a804ce2", "name": "load_p1rlv93_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0060c029-188f-4725-a935-8d0d9cc892f7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a5557f1-421f-4b7b-928f-124c33d795b9"}}}}, {"uuid": "c677df67-d23d-4c53-a4ad-da31ba873674", "name": "f61f8ad5-a993-4e20-be49-6f3094aae04a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1206689642843692, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34257205075767067, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ae9693df-240a-4ac1-ac44-1fa9ec0c4ac9", "name": "e82986f7-3cd6-4361-b8cd-9dcceedd0c16", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c677df67-d23d-4c53-a4ad-da31ba873674"}}}]}, {"uuid": "cba07de9-9ed8-4aaf-915f-356b567f28e9", "name": "load_p1rlv93_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0060c029-188f-4725-a935-8d0d9cc892f7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ae9693df-240a-4ac1-ac44-1fa9ec0c4ac9"}}}}, {"uuid": "f5710e93-0e63-4dda-8322-b339e9baffcc", "name": "a60b88aa-9ce2-438b-acfd-d3a51a091e64_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.365256087534968, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9406994095530364, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d3515b45-b2cd-4e6d-82dc-9d0d1fcf1ff6", "name": "90eba57b-5b28-40a8-8df5-43435c8b0322", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f5710e93-0e63-4dda-8322-b339e9baffcc"}}}]}, {"uuid": "81751aa3-7248-4487-bbb0-b75319417ef3", "name": "load_p1rlv94_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db2d4080-1f43-47a3-9f3a-e25d1e4f5076"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d3515b45-b2cd-4e6d-82dc-9d0d1fcf1ff6"}}}}, {"uuid": "2bcf0af3-f731-4831-b95e-ab9b2c537f24", "name": "4511a972-ce32-4d4c-9040-93b763ddb4f0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.365256087534968, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9406994095530364, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6746918e-c2fb-499a-a5de-c0c2e352830c", "name": "dacd287d-7ee9-4588-a9d7-cc997c4f5b54", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2bcf0af3-f731-4831-b95e-ab9b2c537f24"}}}]}, {"uuid": "3da52a7f-22d5-4c46-9943-4acb1cf2e86d", "name": "load_p1rlv94_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db2d4080-1f43-47a3-9f3a-e25d1e4f5076"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6746918e-c2fb-499a-a5de-c0c2e352830c"}}}}, {"uuid": "9da11bbe-1bb9-4cbe-aaea-cba496a39b01", "name": "7b735d2a-834d-4e2a-bdd2-b01ed3d8ad3d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2874196130666418, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9219654181970236, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "99b4f378-964b-4383-ad8c-0846925d399a", "name": "0c9ff4eb-c022-4e78-8ab2-7bb6a0a5d5b5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9da11bbe-1bb9-4cbe-aaea-cba496a39b01"}}}]}, {"uuid": "7403fe65-1672-4aa6-bd34-9eec32802b07", "name": "load_p1rlv96_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31508077-f731-47cb-94a9-869d7910e406"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "99b4f378-964b-4383-ad8c-0846925d399a"}}}}, {"uuid": "d2b635de-b7b8-4569-9d7e-06f777a219b5", "name": "4a173121-e8c8-4e35-b054-6f8ceb91a0ae_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2874196130666418, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9219654181970236, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e36bcef7-5406-4902-b65c-0dccf635ba6c", "name": "e39255b9-2c3d-4945-acad-e7ab0a898bea", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d2b635de-b7b8-4569-9d7e-06f777a219b5"}}}]}, {"uuid": "07546d73-cdde-49cf-9284-ed9c72056d08", "name": "load_p1rlv96_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31508077-f731-47cb-94a9-869d7910e406"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e36bcef7-5406-4902-b65c-0dccf635ba6c"}}}}, {"uuid": "c16641aa-8d69-474e-83f8-c5385964d545", "name": "04e55605-b003-4b7c-9d1e-ca79dd286853_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.297832728168154, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6109723215697453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c423ba8b-348a-4c26-81c6-ccd5725736f5", "name": "eaeca3f8-e3de-487d-8694-519965bca661", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c16641aa-8d69-474e-83f8-c5385964d545"}}}]}, {"uuid": "ff0f1762-f691-4ce5-ab27-622a05e5025f", "name": "load_p1rlv98_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "82f19d5c-0941-411d-8baa-3ba029471dae"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c423ba8b-348a-4c26-81c6-ccd5725736f5"}}}}, {"uuid": "bf1c9d20-3c94-45dd-b6cd-2ce537df9f0a", "name": "671e29c0-a4f8-4e6f-8a68-960733b787f0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.297832728168154, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6109723215697453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bc14a11d-391f-4b84-8e60-875d7f8679d5", "name": "9fb52573-f6d7-4fcf-925f-e50b3885a9c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bf1c9d20-3c94-45dd-b6cd-2ce537df9f0a"}}}]}, {"uuid": "7905d68d-503b-472c-967a-7778a52f0994", "name": "load_p1rlv98_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "82f19d5c-0941-411d-8baa-3ba029471dae"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bc14a11d-391f-4b84-8e60-875d7f8679d5"}}}}, {"uuid": "7e69ce24-4795-4dbb-b16c-ef9fa0af989d", "name": "6117d5a6-e73f-4b72-89d1-9c9623c39420_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5294251690866196, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6012221542672356, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c78366f5-22c9-4231-a55e-c5b776304b75", "name": "8c7efc8e-047f-4943-afc9-6ddbb1c58202", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7e69ce24-4795-4dbb-b16c-ef9fa0af989d"}}}]}, {"uuid": "e8df70c9-8f8f-4739-abab-34b80d2a23b0", "name": "load_p1rlv99_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc4a448a-c6cb-4714-b8e6-b75bc6bc219c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c78366f5-22c9-4231-a55e-c5b776304b75"}}}}, {"uuid": "c56ce2ea-ddf1-4f61-bb61-b570626f985a", "name": "202db26d-789c-46af-9ccb-e957aec15c92_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5294251690866196, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6012221542672356, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e5fa98dd-17e0-4883-a85e-6066e6729a98", "name": "fdfadd89-1aab-4f45-9ca4-33d1a298628e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c56ce2ea-ddf1-4f61-bb61-b570626f985a"}}}]}, {"uuid": "cd4a408f-1a33-428f-8101-bed597fcb8c3", "name": "load_p1rlv99_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc4a448a-c6cb-4714-b8e6-b75bc6bc219c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e5fa98dd-17e0-4883-a85e-6066e6729a98"}}}}, {"uuid": "184da65b-8dc6-4ca7-8329-4e9be7d55810", "name": "e1145f98-92e2-4c52-a121-c70a893fee4f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.779437116944347, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0510023138100544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "abf9b856-24e3-43b0-993e-941a700e5987", "name": "c4030a1e-6309-4395-954e-04d3068913d1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "184da65b-8dc6-4ca7-8329-4e9be7d55810"}}}]}, {"uuid": "f15e6046-885a-43de-bd29-9aab72b45f9a", "name": "load_p1rlv100_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62a0d673-eaba-4032-9038-8095e2d53999"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "abf9b856-24e3-43b0-993e-941a700e5987"}}}}, {"uuid": "cfd38289-4519-4c78-9e88-aa9280b90980", "name": "75c824d7-7ace-4c79-ad40-933f5f7e2c5e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.779437116944347, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0510023138100544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "04280e76-fa83-4fed-9f67-b16b1e5b6b49", "name": "3a94513d-40ef-46e5-b7ea-92d4868cf199", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cfd38289-4519-4c78-9e88-aa9280b90980"}}}]}, {"uuid": "215191e3-9ef4-4b21-b313-d2806787197c", "name": "load_p1rlv100_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62a0d673-eaba-4032-9038-8095e2d53999"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "04280e76-fa83-4fed-9f67-b16b1e5b6b49"}}}}, {"uuid": "5b4e2d80-8248-4202-a3e8-45a7ae4710f9", "name": "8247a08c-fdb0-411b-8148-73efe847f6ce_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.684904254134122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42635901069761617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "041fd195-9980-4855-8874-8c010832cf81", "name": "0f69f44e-235d-4ce5-9212-23afb844695f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b4e2d80-8248-4202-a3e8-45a7ae4710f9"}}}]}, {"uuid": "3ee2b65f-9dd7-4934-8212-cd6ef1a27825", "name": "load_p1rlv101_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48d1be49-5aca-4e18-8b85-2a1274b3f26d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "041fd195-9980-4855-8874-8c010832cf81"}}}}, {"uuid": "06baf80c-e581-4a2d-8094-32f6084c37d2", "name": "28e8fd55-991f-4d03-a67c-f331858403d8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.684904254134122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42635901069761617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bf9a217b-e25f-4108-8a18-7d0780f3baab", "name": "e6385cf4-58b6-4786-a1b8-c7b9f35d2275", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "06baf80c-e581-4a2d-8094-32f6084c37d2"}}}]}, {"uuid": "9824b145-a3bb-4887-bf47-ca9d0d0e83ed", "name": "load_p1rlv101_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48d1be49-5aca-4e18-8b85-2a1274b3f26d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bf9a217b-e25f-4108-8a18-7d0780f3baab"}}}}, {"uuid": "235cb1eb-79de-4ad0-8c13-d63c4b99b76d", "name": "deb4cd16-3566-4648-9436-d95d86e4dbd4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3841896439528762, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.62886585412856, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8621e40e-4298-42dc-804a-4591b2e0be9c", "name": "4ab2e48e-e6e1-4262-8492-5932347eb446", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "235cb1eb-79de-4ad0-8c13-d63c4b99b76d"}}}]}, {"uuid": "ae29ac6d-f514-4368-abfe-21c408a60c50", "name": "load_p1rlv102_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06a432e3-dd37-4c52-b954-6652bb529c8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8621e40e-4298-42dc-804a-4591b2e0be9c"}}}}, {"uuid": "1d62996a-acb8-4e7a-a168-70dff02adce8", "name": "eeed8d1d-bef3-4c78-a573-cfe779410549_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3841896439528762, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.62886585412856, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ab2839d8-b9ee-435e-bddd-23a2cc6eb79b", "name": "cda44325-54f8-43ee-ba3b-8a801e25efc0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1d62996a-acb8-4e7a-a168-70dff02adce8"}}}]}, {"uuid": "328b551e-2c99-47e8-94d6-1e6d8062cb39", "name": "load_p1rlv102_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06a432e3-dd37-4c52-b954-6652bb529c8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ab2839d8-b9ee-435e-bddd-23a2cc6eb79b"}}}}, {"uuid": "148e865f-b291-44ae-b89a-29810ad5eaa7", "name": "967f2b60-182a-4b89-968b-14af128f040a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2440101223346245, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10648703060010346, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b829b28a-b328-4762-aca6-6fa9fe5838a9", "name": "b40fd67d-119e-4af8-a80c-6f4c065633f9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "148e865f-b291-44ae-b89a-29810ad5eaa7"}}}]}, {"uuid": "fdd5293f-73d1-4c96-8bfc-9c3a25fc0331", "name": "load_p1rlv103_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85afc796-3fe5-4027-b84e-10d502124636"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b829b28a-b328-4762-aca6-6fa9fe5838a9"}}}}, {"uuid": "b0bedc38-f5ec-4329-986f-8320ea45375f", "name": "0640dbbc-4f29-42ba-a44f-a9bafca5c79b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2440101223346245, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10648703060010346, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "368d54dd-4d93-4beb-8956-ab1d59f80508", "name": "b93ea6cb-86f8-4177-be13-5264cefa5c3e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b0bedc38-f5ec-4329-986f-8320ea45375f"}}}]}, {"uuid": "e8f19935-fdb6-422c-a4ea-650290277367", "name": "load_p1rlv103_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85afc796-3fe5-4027-b84e-10d502124636"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "368d54dd-4d93-4beb-8956-ab1d59f80508"}}}}, {"uuid": "aea1ad96-2ffc-46ed-b4b6-62581ccf1126", "name": "2843f780-0c39-4f88-9e82-8a49607d6a80_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.651721747239447, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.750976002130125, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ba45d071-0691-4fb5-a0fa-d9fbb2f0a8f1", "name": "7344c816-a488-4607-869f-eca427b482d9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aea1ad96-2ffc-46ed-b4b6-62581ccf1126"}}}]}, {"uuid": "0f430a54-77f8-46b6-bbc2-0a0f6f19955f", "name": "load_p1rlv104_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c76c5b8f-1994-470c-a024-b97c73b9bb41"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ba45d071-0691-4fb5-a0fa-d9fbb2f0a8f1"}}}}, {"uuid": "79e38f7e-8b83-4854-b01a-4431739ddef2", "name": "eeefaf38-2a4e-4ed2-a228-202d34333004_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.651721747239447, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.750976002130125, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d960e788-92fb-47d2-8fca-56b2768f1a29", "name": "b7563fdf-9304-4cbf-b1bc-ee9f9adad567", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "79e38f7e-8b83-4854-b01a-4431739ddef2"}}}]}, {"uuid": "bd4d9be8-ecf0-4c23-82f2-e58b4760da60", "name": "load_p1rlv104_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c76c5b8f-1994-470c-a024-b97c73b9bb41"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d960e788-92fb-47d2-8fca-56b2768f1a29"}}}}, {"uuid": "2e8536ec-1a2e-4e27-85a8-b467888ca835", "name": "13b2f988-564c-443c-baad-c2eb203cf2aa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c1ec30df-0bdb-4026-9bc4-a04b856b74e9", "name": "140b9b1c-e959-4ce0-bffa-25f4579b2333", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2e8536ec-1a2e-4e27-85a8-b467888ca835"}}}]}, {"uuid": "d8bfa8fc-8fbd-4255-90e5-e27ccaaa2648", "name": "load_p1rlv105_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fe82ede-430d-454d-b9d0-e212d0621ea1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c1ec30df-0bdb-4026-9bc4-a04b856b74e9"}}}}, {"uuid": "f8007fef-a4cb-415b-a99b-a5914e404d70", "name": "7684eece-222c-4a8a-92f3-bc8020f4d912_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3105f80b-d304-4233-a025-1f6c2ecd50d3", "name": "4f238f30-c677-4975-a961-050e8ea1bed9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8007fef-a4cb-415b-a99b-a5914e404d70"}}}]}, {"uuid": "578f8926-bd9e-4b24-a882-5acb77252820", "name": "load_p1rlv105_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fe82ede-430d-454d-b9d0-e212d0621ea1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3105f80b-d304-4233-a025-1f6c2ecd50d3"}}}}, {"uuid": "14fae872-1b77-45ce-add0-e7976b3630fd", "name": "ed854caa-4326-4a77-93b2-0b14fe09ff85_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.30121669259111117, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.11773911124465561, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9b677954-9657-4c65-ba63-087dba6ab1bb", "name": "f6bc12e0-cfc4-4bc2-b323-86d2ea685920", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "14fae872-1b77-45ce-add0-e7976b3630fd"}}}]}, {"uuid": "f6200b6c-6b46-41fb-b3c5-1862a8054e9d", "name": "load_p1rlv107_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "096e92a6-ea34-435e-a059-57d5234e1654"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9b677954-9657-4c65-ba63-087dba6ab1bb"}}}}, {"uuid": "8ae42569-ca98-43cd-a5f8-37969e71c278", "name": "5691c38e-10b3-48f2-bf5a-2fe899952497_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.30121669259111117, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.11773911124465561, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3c6b4294-6bed-4537-9fa8-ee36816240ed", "name": "63298650-1925-432c-800a-ed81441ae492", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ae42569-ca98-43cd-a5f8-37969e71c278"}}}]}, {"uuid": "ffaf6895-8364-48e3-8054-1985456b2eab", "name": "load_p1rlv107_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "096e92a6-ea34-435e-a059-57d5234e1654"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3c6b4294-6bed-4537-9fa8-ee36816240ed"}}}}, {"uuid": "c35b2abf-c50e-4d68-ad3d-9ae50af82d54", "name": "d0ef8001-1275-4a80-a82a-0af9540d10b9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.522559572152904, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23989402539717328, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e88bd1c6-bc36-40cd-b0c1-7c15933cc79f", "name": "e42ef0cb-6e24-4453-a4b7-866902a90c1e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c35b2abf-c50e-4d68-ad3d-9ae50af82d54"}}}]}, {"uuid": "069c0311-57f5-4fb5-9df1-29924928c296", "name": "load_p1rlv108_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "afc70b80-ab76-440c-b05b-149458051675"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e88bd1c6-bc36-40cd-b0c1-7c15933cc79f"}}}}, {"uuid": "71b788fb-ce89-48a2-aceb-69953c603aab", "name": "79c06ebe-683b-49e5-ad12-61270762b53d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.522559572152904, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23989402539717328, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cf8a5e2f-b19e-41a5-8bff-338e32c1e09c", "name": "fa4c6444-08bd-47a2-97ed-04ada0ff6b1e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "71b788fb-ce89-48a2-aceb-69953c603aab"}}}]}, {"uuid": "3fd99e63-6ab6-44a5-b868-531cf263e5f9", "name": "load_p1rlv108_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "afc70b80-ab76-440c-b05b-149458051675"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cf8a5e2f-b19e-41a5-8bff-338e32c1e09c"}}}}, {"uuid": "8f1d6e19-6d64-4f97-855a-c6626c5778af", "name": "b3e647d6-daaa-422c-871a-4016fbbdddf6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5369480608064634, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2969034126636569, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "516685fd-7351-4510-9728-85aacad9a207", "name": "55c7787a-4d3a-4737-a3a5-8165bcc1d472", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8f1d6e19-6d64-4f97-855a-c6626c5778af"}}}]}, {"uuid": "054abb3b-f1d6-4857-817d-e614797894a3", "name": "load_p1rlv109_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c76fc99c-c160-4ed0-85dd-ec3da962bb24"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "516685fd-7351-4510-9728-85aacad9a207"}}}}, {"uuid": "d62c79c8-4ebc-4d85-9274-1a052f286007", "name": "5ba0d181-1f41-4828-9153-763fc26a1566_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5369480608064634, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2969034126636569, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c979a193-0990-4901-a9ce-244a39c8b763", "name": "ae7c6d8c-3bfe-4e99-8b38-53f7bc6eef9e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d62c79c8-4ebc-4d85-9274-1a052f286007"}}}]}, {"uuid": "1650bce1-bb01-4df4-84aa-eea243ec7930", "name": "load_p1rlv109_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c76fc99c-c160-4ed0-85dd-ec3da962bb24"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c979a193-0990-4901-a9ce-244a39c8b763"}}}}, {"uuid": "24517943-5fde-4054-a339-befca697a048", "name": "4a5ecdab-80cf-4c43-aa11-c20c7ec88038_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4292209363155218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1643515800752328, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f171827b-d16c-4336-9893-c9d50b9e59e0", "name": "b14c8827-88b8-436f-9b1f-b3b1d850c4cf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "24517943-5fde-4054-a339-befca697a048"}}}]}, {"uuid": "d765a2ab-2053-435f-8de7-4c64abc39b0e", "name": "load_p1rlv111_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66748ae6-b6ef-4228-bb0f-f9a121f0e1a3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f171827b-d16c-4336-9893-c9d50b9e59e0"}}}}, {"uuid": "5b0e7b80-45b2-493b-8d9c-424d3d62917b", "name": "d450675c-b18c-41b0-a158-ea2f17f93e06_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4292209363155218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1643515800752328, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f5ab6d2-eb37-49ce-b90a-6435b99c77cd", "name": "3502e7b3-7a68-4ce9-8819-f7679319c5e4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b0e7b80-45b2-493b-8d9c-424d3d62917b"}}}]}, {"uuid": "072461f1-614b-4520-9bef-105e7407bd14", "name": "load_p1rlv111_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66748ae6-b6ef-4228-bb0f-f9a121f0e1a3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f5ab6d2-eb37-49ce-b90a-6435b99c77cd"}}}}, {"uuid": "a129d215-5479-4777-9afd-005fee86592b", "name": "35399736-e507-42af-9286-645d637ea53c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.554325896527151, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5828877012431191, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2ea15295-5d76-48a2-ad39-163db0210208", "name": "b60cd738-ea7d-451b-9fd2-10a38368b834", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a129d215-5479-4777-9afd-005fee86592b"}}}]}, {"uuid": "d37897bf-4995-482d-afae-238a3e5a4765", "name": "load_p1rlv112_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25edc94b-a44b-4200-8cde-73941c2818b8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2ea15295-5d76-48a2-ad39-163db0210208"}}}}, {"uuid": "0ad87fe1-fd4e-495a-a783-359e0194239e", "name": "c665dc92-5a1c-489b-947b-d94f6473342b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.554325896527151, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5828877012431191, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5d7aca6c-9fb3-4efd-9124-b1b7c09671cc", "name": "c95acac6-e43d-4abf-96a7-26ee5bd498a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0ad87fe1-fd4e-495a-a783-359e0194239e"}}}]}, {"uuid": "52b08107-3aaf-466d-aaa2-91607658bc6a", "name": "load_p1rlv112_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25edc94b-a44b-4200-8cde-73941c2818b8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5d7aca6c-9fb3-4efd-9124-b1b7c09671cc"}}}}, {"uuid": "f55f35ca-f906-479e-ada5-5b15d640dd78", "name": "0391e0ae-e8b6-4758-af68-2b1e73941310_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0288569450045768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2608148575838028, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5d05da5e-7c57-4473-894a-9cbd25435b09", "name": "ec30e385-acc1-45b8-ad4f-a7e08a1a93d0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f55f35ca-f906-479e-ada5-5b15d640dd78"}}}]}, {"uuid": "e5606f88-9627-4fde-819e-6a380b5a979b", "name": "load_p1rlv113_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2756378a-0c67-47cf-969d-bdb9e55c8a4b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5d05da5e-7c57-4473-894a-9cbd25435b09"}}}}, {"uuid": "35a42fc6-3d27-405c-b689-6461c37d0bf0", "name": "2e8e1a08-4c19-4975-a423-2bf62e7d8243_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0288569450045768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2608148575838028, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "663fbd3f-6296-4deb-8d4b-239d3aedb205", "name": "b241c0d4-30a7-46eb-bbf8-ae3c01cdc319", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "35a42fc6-3d27-405c-b689-6461c37d0bf0"}}}]}, {"uuid": "42b5dc58-5ed3-42bb-a34e-9f6785057db3", "name": "load_p1rlv113_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2756378a-0c67-47cf-969d-bdb9e55c8a4b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "663fbd3f-6296-4deb-8d4b-239d3aedb205"}}}}, {"uuid": "ee0e5033-82a3-4694-bbb8-33ad3d267e04", "name": "a7547c44-ed9f-4704-a038-b3fbd10d21a0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7419011483459746, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17632142927590772, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c8eeb9e6-96c3-4a2b-bc38-71d012f39165", "name": "50f3db76-64cf-4e1b-a57e-c7172cc3fa46", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ee0e5033-82a3-4694-bbb8-33ad3d267e04"}}}]}, {"uuid": "a14b9591-bce8-4a3f-9c90-e1f4b8a6954b", "name": "load_p1rlv114_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7934cd3-dcd6-4b67-8206-8a3636b6f75d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c8eeb9e6-96c3-4a2b-bc38-71d012f39165"}}}}, {"uuid": "9f118354-5ba0-4d57-b544-d315fa665779", "name": "197f306d-8b59-49a8-b384-bec24c9297a5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7419011483459746, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17632142927590772, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "97559216-4f7a-4506-b67e-9278e3f53e4c", "name": "5b8e997f-2eae-4714-9dc7-c452c92d4a90", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9f118354-5ba0-4d57-b544-d315fa665779"}}}]}, {"uuid": "9d62d752-2c7b-4ee0-8f15-1839d9751b31", "name": "load_p1rlv114_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7934cd3-dcd6-4b67-8206-8a3636b6f75d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "97559216-4f7a-4506-b67e-9278e3f53e4c"}}}}, {"uuid": "b6fd0128-bc95-4086-9e43-7c8ccf220076", "name": "5cd4b925-275d-4ca5-b7bd-64fda137a71d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.883515343353138, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18989418857380705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "878e8f33-af62-487e-9af6-6d0c498d84c8", "name": "8e522171-e97f-471d-8866-b02f7a5f77d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b6fd0128-bc95-4086-9e43-7c8ccf220076"}}}]}, {"uuid": "57839523-1c75-459f-a365-3cd8fbb9fde7", "name": "load_p1rlv115_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "919a48e8-b378-4dd5-8e33-a2602fb58bc0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "878e8f33-af62-487e-9af6-6d0c498d84c8"}}}}, {"uuid": "862cf827-2fa0-4e3a-9d53-d3de3cfff5ee", "name": "1b7f0e82-7b47-4d9b-ac23-d5091debc8bf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.883515343353138, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18989418857380705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1ff35b48-6c02-4af4-943b-a9c4140b8678", "name": "9b5134e1-42e0-4eee-a0b1-f27c6d61ab86", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "862cf827-2fa0-4e3a-9d53-d3de3cfff5ee"}}}]}, {"uuid": "a5b6fcd7-3c22-4997-bb4a-90ad17d41503", "name": "load_p1rlv115_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "919a48e8-b378-4dd5-8e33-a2602fb58bc0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1ff35b48-6c02-4af4-943b-a9c4140b8678"}}}}, {"uuid": "23f0b4e3-06ad-46a0-8acb-16543172da24", "name": "19b07006-31d9-4290-bbb7-26a3a12507fd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7362273540893955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24527287728713068, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e1548353-7017-48de-a9e3-439c9a0bba57", "name": "85aa85ca-0027-4da8-b581-95318cc8a814", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "23f0b4e3-06ad-46a0-8acb-16543172da24"}}}]}, {"uuid": "b5abfb5c-782d-4495-9bd1-e78f868ffb9d", "name": "load_p1rlv117_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e6de569-7f61-439e-a402-850c4f071ab3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e1548353-7017-48de-a9e3-439c9a0bba57"}}}}, {"uuid": "53447ca1-e6c3-4a00-9395-443683755039", "name": "a1db1749-39b2-4dc5-9bb5-b31dca0be6c1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7362273540893955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24527287728713068, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2d59efa9-d691-4ccc-b6a5-27c0fc8f2426", "name": "2f4bafcf-2bc3-4dcc-86e1-1a9567cbaf83", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "53447ca1-e6c3-4a00-9395-443683755039"}}}]}, {"uuid": "80f37d62-ee74-4124-a567-ee5a167a8543", "name": "load_p1rlv117_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e6de569-7f61-439e-a402-850c4f071ab3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2d59efa9-d691-4ccc-b6a5-27c0fc8f2426"}}}}, {"uuid": "e2e4aab7-cf99-48e7-8453-2f94b42aff45", "name": "806914aa-76f2-4988-b1d7-30aca0006156_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.074192704000552, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.129078804753558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "59d83935-cfff-4b37-9176-83da5cd721ff", "name": "98dea8e0-46fc-4d34-bf83-c423a96b79c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e2e4aab7-cf99-48e7-8453-2f94b42aff45"}}}]}, {"uuid": "4e09f639-e11f-4eab-89f1-fafcd4d8cb28", "name": "load_p1rlv118_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "247e37b3-d6d0-41d7-a6b3-ee29d415da50"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "59d83935-cfff-4b37-9176-83da5cd721ff"}}}}, {"uuid": "84bb5902-a714-4e27-aa5d-9b93b75ab90a", "name": "d3b07c70-907f-49c6-b00f-8af495f1e472_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.074192704000552, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.129078804753558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e8ec978d-abb5-4c1a-9abc-40e33eaad1f7", "name": "cefc2605-e448-422f-b93b-4c11333bf9fd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "84bb5902-a714-4e27-aa5d-9b93b75ab90a"}}}]}, {"uuid": "72198056-05f5-4903-8c74-c691d4a32759", "name": "load_p1rlv118_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "247e37b3-d6d0-41d7-a6b3-ee29d415da50"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e8ec978d-abb5-4c1a-9abc-40e33eaad1f7"}}}}, {"uuid": "719a89dd-b219-461d-81df-9f94b751432c", "name": "72182001-19d6-49c5-900d-f269aff2bea9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9571923411347831, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7946531538551662, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "59b30b42-f074-4170-92eb-b8bca83fa949", "name": "9bf0adc2-c199-423c-9395-851dadee10ea", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "719a89dd-b219-461d-81df-9f94b751432c"}}}]}, {"uuid": "33eaf0d1-0bf8-44c0-b0e5-452a215c3cb7", "name": "load_p1rlv119_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee33d90b-2f70-4c9d-863d-6486b95280b8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "59b30b42-f074-4170-92eb-b8bca83fa949"}}}}, {"uuid": "a8d19fde-9e9f-4fbf-8126-909580c17469", "name": "4e0c6550-e775-46e3-9879-acb13d1bdc30_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9571923411347831, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7946531538551662, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "583f5ac1-4c54-4883-8660-c250b7e3cb04", "name": "33bc3b30-57e1-46aa-bc52-31df7304976a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a8d19fde-9e9f-4fbf-8126-909580c17469"}}}]}, {"uuid": "cfe435c8-1fe6-4078-bdb4-a7d971412db5", "name": "load_p1rlv119_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee33d90b-2f70-4c9d-863d-6486b95280b8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "583f5ac1-4c54-4883-8660-c250b7e3cb04"}}}}, {"uuid": "27bf5446-2162-4885-b371-253ccb53de9b", "name": "f8adb0fa-f9c1-493e-b521-27f42c67975b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.297832728168154, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6109723215697453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4611dda0-db86-4242-915a-95dba9b96f8d", "name": "b7856dc6-74d1-4807-a9ee-fc7deb551e87", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "27bf5446-2162-4885-b371-253ccb53de9b"}}}]}, {"uuid": "82a70d6b-169a-4b40-8005-32e139b77ad0", "name": "load_p1rlv120_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a02925cd-7c5b-475f-9e91-30d639bb3c33"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4611dda0-db86-4242-915a-95dba9b96f8d"}}}}, {"uuid": "fad7872b-c335-45bc-aa98-e49b2eca9feb", "name": "ab1c6fed-c9bf-41cb-9a4b-bedce3492fb6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.297832728168154, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6109723215697453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b8fd66d8-f1ee-4917-b670-e9270f82689d", "name": "8566d8fa-2057-401d-860c-630f8ef812f8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fad7872b-c335-45bc-aa98-e49b2eca9feb"}}}]}, {"uuid": "7630ba82-773b-4559-9b9c-8880d22169e5", "name": "load_p1rlv120_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a02925cd-7c5b-475f-9e91-30d639bb3c33"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b8fd66d8-f1ee-4917-b670-e9270f82689d"}}}}, {"uuid": "13b895c5-18b1-4554-a332-4f8bdb4cb7e6", "name": "051a4bcc-e931-46ee-9d3c-808bd76a3c3f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.876043044068563, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8047319040687714, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e59e9b91-2be7-427f-8d2a-b439f06209a6", "name": "fada6878-7d42-49a2-807e-377e437143ff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "13b895c5-18b1-4554-a332-4f8bdb4cb7e6"}}}]}, {"uuid": "afb00e2d-1f8c-48e1-8edf-bb710714ed07", "name": "load_p1rlv121_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0dbaab50-3abc-4207-82dc-5fcc5be68aad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e59e9b91-2be7-427f-8d2a-b439f06209a6"}}}}, {"uuid": "a27d63eb-6dcd-40dc-8442-7c8671032d02", "name": "857e4ea9-3b0f-4208-9244-0af42af4a7e3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.876043044068563, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8047319040687714, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2718d551-8cf3-4600-9dc3-b4c3665e8a0e", "name": "33a47752-67d3-4b44-bde6-d9c114f75f21", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a27d63eb-6dcd-40dc-8442-7c8671032d02"}}}]}, {"uuid": "8ce1fecd-0c60-473b-869a-8a5bf9ff6166", "name": "load_p1rlv121_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0dbaab50-3abc-4207-82dc-5fcc5be68aad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2718d551-8cf3-4600-9dc3-b4c3665e8a0e"}}}}, {"uuid": "49b0e4ba-7ca3-4d34-af13-7e25824e6a76", "name": "1b47beed-07a2-45ae-b215-79e50838f478_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2437699409140923, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5571842941855458, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "84efaaec-d9f7-483f-9ab6-fc0a55a52f8c", "name": "7e10c91e-d599-4df1-a1fe-96851d0cf4a5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "49b0e4ba-7ca3-4d34-af13-7e25824e6a76"}}}]}, {"uuid": "e595319f-e5d3-498c-a031-e65dbe57223c", "name": "load_p1rlv122_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b02739e-d082-4c54-8deb-8ccc83ab82ab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "84efaaec-d9f7-483f-9ab6-fc0a55a52f8c"}}}}, {"uuid": "962e79fe-c222-4e40-9c9f-abbc2ce59cb0", "name": "067aa084-2c75-4d15-97aa-78b3e0b0a153_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2437699409140923, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5571842941855458, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7fa14ede-ebce-495f-9e9f-41b61144d1ff", "name": "3ad50f32-b317-4906-82aa-07733944795c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "962e79fe-c222-4e40-9c9f-abbc2ce59cb0"}}}]}, {"uuid": "eeffb200-c11b-446a-a198-cb403bac7beb", "name": "load_p1rlv122_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b02739e-d082-4c54-8deb-8ccc83ab82ab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7fa14ede-ebce-495f-9e9f-41b61144d1ff"}}}}, {"uuid": "8baad36a-cd5c-4c30-adee-29e71781f3fd", "name": "0dfa85db-08dc-409e-970c-c904c5c307bf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9353742885016981, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3630006054680373, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3c97fce8-7ca0-4309-b2eb-511d255f7ca8", "name": "b2bdc887-8e68-4385-a40f-325bfc8eab82", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8baad36a-cd5c-4c30-adee-29e71781f3fd"}}}]}, {"uuid": "f81f35ba-48df-4e21-9762-47dd4726f97d", "name": "load_p1rlv123_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6184fe8d-ae60-426a-8c0c-a3cc56c5b67e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3c97fce8-7ca0-4309-b2eb-511d255f7ca8"}}}}, {"uuid": "78b81e4a-3d2f-426f-b57f-85fbb095427c", "name": "c66c5166-c614-43f0-b2ea-ec48f019e1a1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9353742885016981, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3630006054680373, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4f4521b7-d7f6-4ec4-acff-ed7bc763dae0", "name": "416a179a-0784-4248-a2eb-67f0088efceb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "78b81e4a-3d2f-426f-b57f-85fbb095427c"}}}]}, {"uuid": "7c31539f-f638-4d65-965a-9d3ea5776d58", "name": "load_p1rlv123_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6184fe8d-ae60-426a-8c0c-a3cc56c5b67e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4f4521b7-d7f6-4ec4-acff-ed7bc763dae0"}}}}, {"uuid": "b3b2c077-f49b-4ef2-a732-d105b0c18c23", "name": "564c20b2-c549-4e21-a5d2-8ad1ba2d061a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4794755457968312, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.46197673612457824, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0fd74c8f-5b7d-440d-ab7b-58c8362163a4", "name": "e570946e-a438-4421-bcc5-7d72ca2612b9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b3b2c077-f49b-4ef2-a732-d105b0c18c23"}}}]}, {"uuid": "686de60c-d247-410b-b7f5-5fcfa2b57dd2", "name": "load_p1rlv124_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e5ca78b-6151-4a35-8a04-1bab215f0f10"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0fd74c8f-5b7d-440d-ab7b-58c8362163a4"}}}}, {"uuid": "3fda8210-f058-400a-95f6-942ca84ae691", "name": "1ce44c52-127a-4e74-b8ef-551022d11d8e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4794755457968312, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.46197673612457824, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b1c9a482-b6ba-4487-9ea8-6c9b7b2aa794", "name": "6aee4861-997c-47f7-a71a-8e27165836d7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3fda8210-f058-400a-95f6-942ca84ae691"}}}]}, {"uuid": "ae132a9a-c8c1-4756-9475-eaee18f1b99a", "name": "load_p1rlv124_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e5ca78b-6151-4a35-8a04-1bab215f0f10"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b1c9a482-b6ba-4487-9ea8-6c9b7b2aa794"}}}}, {"uuid": "b612dfd9-e950-4218-9a85-4200a50d317b", "name": "d1a68747-d3aa-44a9-8aa7-2f4992abe586_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "93059b3a-00fa-44b9-9ad6-92cd637f51fe", "name": "53bd28d2-e9a5-4b07-8ae7-1ed70eb98476", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b612dfd9-e950-4218-9a85-4200a50d317b"}}}]}, {"uuid": "b1748623-6759-4b31-93a1-5bf78c59fb76", "name": "load_p1rlv125_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3367cc2-b096-4cfb-ae71-038eb9e06b46"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "93059b3a-00fa-44b9-9ad6-92cd637f51fe"}}}}, {"uuid": "4c023815-5ad6-4f31-95d2-146176a71953", "name": "fcc40596-9760-41d7-94ed-8f6f7cd31098_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4a3e0581-451c-4c23-a56f-cf3fe911cef8", "name": "fe993a5d-8671-43a7-8e67-9d9689673f1d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4c023815-5ad6-4f31-95d2-146176a71953"}}}]}, {"uuid": "37e8cddf-d42e-4ce9-885b-d33d9cfe3388", "name": "load_p1rlv125_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3367cc2-b096-4cfb-ae71-038eb9e06b46"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4a3e0581-451c-4c23-a56f-cf3fe911cef8"}}}}, {"uuid": "8d060410-1b28-4508-841f-1a239a00d098", "name": "bea2eb65-94f6-44d6-a077-5c7ecacd7036_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5229589832640044, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3359880712066463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e4521922-851e-47ab-bd82-4c196fade484", "name": "a34ea912-dd78-4e06-8965-d6a42c1c87db", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8d060410-1b28-4508-841f-1a239a00d098"}}}]}, {"uuid": "4ef7ff68-ddbb-4dc5-8c3a-fd7218a0591c", "name": "load_p1rlv127_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ae7b1fe-08c4-4848-867e-e2426a325a99"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e4521922-851e-47ab-bd82-4c196fade484"}}}}, {"uuid": "9d1fb586-95ba-4e57-889e-356da6c25cb4", "name": "c59cec42-74f7-4e00-b345-b23208a2b15f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5229589832640044, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3359880712066463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fee10c7c-3ab1-48aa-b412-8bd7d2573dce", "name": "9b24d381-d5f0-43e9-bb9c-fa7a959c0857", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9d1fb586-95ba-4e57-889e-356da6c25cb4"}}}]}, {"uuid": "ac210a2b-1851-4e76-816d-e4e7b4899f93", "name": "load_p1rlv127_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ae7b1fe-08c4-4848-867e-e2426a325a99"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fee10c7c-3ab1-48aa-b412-8bd7d2573dce"}}}}, {"uuid": "b2b15cde-b33b-4e37-b2cf-5316406072de", "name": "64283c63-b3dc-4aee-bf3c-cc0f8573e2f1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4040789998842194, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4565305929598704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "79f9cf11-c820-47a1-9b74-f7369ae38b9f", "name": "47ef9dc3-4340-4d69-b3a7-a480ff9a4e5b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b2b15cde-b33b-4e37-b2cf-5316406072de"}}}]}, {"uuid": "cec1091b-7501-4f4e-b710-95c483f07f5d", "name": "load_p1rlv128_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56bc8935-c658-424c-83d8-0d13bf8d292a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "79f9cf11-c820-47a1-9b74-f7369ae38b9f"}}}}, {"uuid": "f8773ad2-a5dd-4a15-9301-b781dc157354", "name": "ca7087ae-5b39-413c-a0fc-bee47dafc86e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4040789998842194, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4565305929598704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "732c4bbf-d4bf-4149-8316-f476c8c78a2d", "name": "06b6bbb7-9c54-4598-b096-9dc27b8102b1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8773ad2-a5dd-4a15-9301-b781dc157354"}}}]}, {"uuid": "f9ac8698-72e1-42bb-90f8-d43a78c28a3d", "name": "load_p1rlv128_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56bc8935-c658-424c-83d8-0d13bf8d292a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "732c4bbf-d4bf-4149-8316-f476c8c78a2d"}}}}, {"uuid": "eedc1026-34be-47de-a2e0-f3e6ea500bf1", "name": "6b5e0677-f402-49ad-b4ac-193d1f15bed2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7537427041030689, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.37349948863112625, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4574fab1-142f-4cb8-a0b1-dac68b4ab565", "name": "3c75864d-6bb4-4f6f-9f9b-72ae7985f0fd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eedc1026-34be-47de-a2e0-f3e6ea500bf1"}}}]}, {"uuid": "d7f4afb4-7503-4c66-8194-4661a71cb399", "name": "load_p1rlv129_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6c42586-4f46-45c6-910f-90fca771cfd2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4574fab1-142f-4cb8-a0b1-dac68b4ab565"}}}}, {"uuid": "24d808e0-a25d-41bc-8aaf-9990eccb7ab4", "name": "56088df8-55c7-4fdc-896a-5f04e6ccb015_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7537427041030689, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.37349948863112625, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f39fe77-3d73-48ab-92ba-9fb9f8622ce2", "name": "f250c745-893d-400e-85f3-dccb3b92119b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "24d808e0-a25d-41bc-8aaf-9990eccb7ab4"}}}]}, {"uuid": "d92713c4-e2f3-475e-80e6-43f4332b0f7c", "name": "load_p1rlv129_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6c42586-4f46-45c6-910f-90fca771cfd2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f39fe77-3d73-48ab-92ba-9fb9f8622ce2"}}}}, {"uuid": "7206e78c-dc01-4a88-87dc-92f12b81c5ed", "name": "85c77c54-09b7-4b11-99df-3d2d2fb35559_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.297832728168154, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6109723215697453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4a29d63e-dea1-442d-a272-760c694e029c", "name": "9222c3b6-9c12-463a-8ec0-a7a065b61a82", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7206e78c-dc01-4a88-87dc-92f12b81c5ed"}}}]}, {"uuid": "c0a5d83c-19a2-4bbe-b430-96cd86c3ec5d", "name": "load_p1rlv130_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5c96953-6710-4765-b5bd-4359e03e4c63"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4a29d63e-dea1-442d-a272-760c694e029c"}}}}, {"uuid": "79588cfd-8b16-4b36-a195-5326be554ce5", "name": "a1928b35-55c4-4a97-bb90-117bc2179089_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.297832728168154, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6109723215697453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "780efec7-3429-400e-826c-6f883f72604d", "name": "36491887-4033-4fee-a6d9-2f3cac618305", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "79588cfd-8b16-4b36-a195-5326be554ce5"}}}]}, {"uuid": "7e42a97a-9ca0-445f-89dc-e988ed19372b", "name": "load_p1rlv130_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5c96953-6710-4765-b5bd-4359e03e4c63"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "780efec7-3429-400e-826c-6f883f72604d"}}}}, {"uuid": "9b2700f3-4011-4344-bdf5-7dc7f7441c55", "name": "3e5929fc-8438-437c-8433-c5f322bc79ba_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3885774782241163, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12624891415512582, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "390771cc-dc65-47c4-8419-4787ae8f5e54", "name": "b665265e-dc12-4058-8a80-9a4aaf2a8bcf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9b2700f3-4011-4344-bdf5-7dc7f7441c55"}}}]}, {"uuid": "5413e231-368b-4a65-8ed8-a723bdf8923d", "name": "load_p1rlv131_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "499fb461-ccb6-436a-8078-eec9beffb4a9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "390771cc-dc65-47c4-8419-4787ae8f5e54"}}}}, {"uuid": "c4778803-e672-41a7-94e1-30a30aa54414", "name": "343e43df-a998-42a9-a472-71fac05ed739_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3885774782241163, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12624891415512582, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1822e842-8251-466f-b5a8-9dfbd1cf9d26", "name": "747b0fbe-bcf2-4d83-b894-a7ebfa1d1448", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c4778803-e672-41a7-94e1-30a30aa54414"}}}]}, {"uuid": "3a3aa4b8-ceae-4213-a03e-7a8dc52d0961", "name": "load_p1rlv131_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "499fb461-ccb6-436a-8078-eec9beffb4a9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1822e842-8251-466f-b5a8-9dfbd1cf9d26"}}}}, {"uuid": "39b9e37a-0501-4cc6-b4a9-74a2fc2b9cf0", "name": "8a32d994-7583-4752-b441-2f6e02dd5b1d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0137187800791063, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5284248988065299, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8e10c4cb-8e1d-4851-8987-ae9eace6d8d0", "name": "f6478ee6-3a57-4bba-94ee-56361b3e3858", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "39b9e37a-0501-4cc6-b4a9-74a2fc2b9cf0"}}}]}, {"uuid": "3f42414d-fc02-43d7-91a3-6ad9eb55c592", "name": "load_p1rlv132_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41960437-e2e6-4746-89c2-81c81602ca1b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8e10c4cb-8e1d-4851-8987-ae9eace6d8d0"}}}}, {"uuid": "69280a7b-28c9-4d85-877f-dd1248b7248b", "name": "1f19a2e4-25a5-407b-8454-2be5b63972a5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0137187800791063, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5284248988065299, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "164140b5-919a-4b39-93e9-6db867cf4762", "name": "7fb42886-cae4-444b-92db-facbd41dab72", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "69280a7b-28c9-4d85-877f-dd1248b7248b"}}}]}, {"uuid": "ae0dee1d-c463-4e8f-ae0a-82810bc1685d", "name": "load_p1rlv132_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41960437-e2e6-4746-89c2-81c81602ca1b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "164140b5-919a-4b39-93e9-6db867cf4762"}}}}, {"uuid": "fb417fec-33bd-4084-8f82-6d11748f2047", "name": "a9795b2b-4b87-4110-8a14-78afd0d49d64_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.046232297850773, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7285366000251032, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3064bd57-4ffc-4deb-8735-6d075a485d9f", "name": "96357b25-56ee-4f8d-9da2-a3e83610934a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fb417fec-33bd-4084-8f82-6d11748f2047"}}}]}, {"uuid": "e3f43d0b-7c14-40bf-8d16-648e9e170049", "name": "load_p1rlv133_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31dc8280-eb14-4f87-85d7-8eae17013fe7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3064bd57-4ffc-4deb-8735-6d075a485d9f"}}}}, {"uuid": "f985227a-08b1-43a1-8e47-a22acac88d68", "name": "710369ac-a8d0-4c38-93a8-46b84dd1d8a7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.046232297850773, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7285366000251032, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d3331dab-f1a0-40fa-81e9-63713ffc2b94", "name": "f3f63640-6d2d-44e9-9790-fa94d65bf3a0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f985227a-08b1-43a1-8e47-a22acac88d68"}}}]}, {"uuid": "a4597a71-10a4-4e27-b3cf-0a95e3532ec2", "name": "load_p1rlv133_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31dc8280-eb14-4f87-85d7-8eae17013fe7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d3331dab-f1a0-40fa-81e9-63713ffc2b94"}}}}, {"uuid": "c93cb390-e017-4571-8bdc-951a3c7934e2", "name": "09bdff91-2037-4c18-ba7b-a04c66ed49b6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.749950841708346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2019248045205122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c73fef17-c587-4230-b668-dff1db537a28", "name": "154ddc07-d012-4fdd-9991-5b1ca9c716dd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c93cb390-e017-4571-8bdc-951a3c7934e2"}}}]}, {"uuid": "347cf23e-5bb8-4ca9-bf4c-f95fe4d6aed4", "name": "load_p1rlv134_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "425bdcfa-9753-4ef5-bb38-9e014ae779dc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c73fef17-c587-4230-b668-dff1db537a28"}}}}, {"uuid": "a92c0e23-02e5-4950-8be3-f8c9e8c4591d", "name": "2a8bc7d6-7297-4097-8dfd-1c6494a98a65_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.749950841708346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2019248045205122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e19a7870-8be5-4d5e-8652-16b430939a8d", "name": "868745ea-71dc-4326-a57b-7f61af0d2ab9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a92c0e23-02e5-4950-8be3-f8c9e8c4591d"}}}]}, {"uuid": "266eefbd-2122-4ee6-9540-516ad6889ef8", "name": "load_p1rlv134_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "425bdcfa-9753-4ef5-bb38-9e014ae779dc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e19a7870-8be5-4d5e-8652-16b430939a8d"}}}}, {"uuid": "95ec5f2b-b490-42f4-8ee2-9ca02be4da2c", "name": "45df5033-41fe-4d79-b003-347016b718a8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.42648220197083947, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17627708866943506, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d5775010-abb6-406d-84d4-10da14e4a029", "name": "fb2cf978-0429-4a12-969a-5bb046e1aa57", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "95ec5f2b-b490-42f4-8ee2-9ca02be4da2c"}}}]}, {"uuid": "941505d8-b4bb-420d-ad6e-167a2ebd2c3a", "name": "load_p1rlv135_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbdefe7a-517b-495b-88b8-dcf15a9429ff"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d5775010-abb6-406d-84d4-10da14e4a029"}}}}, {"uuid": "bad99740-a014-4f26-bf2e-7387137923c8", "name": "79792ac0-069b-447a-a970-b0bc553883d1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.42648220197083947, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17627708866943506, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50f95d46-0ac6-48ff-95ad-00338df71ef2", "name": "0394e936-e0cc-4fd8-8fcc-9cfc4332f150", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bad99740-a014-4f26-bf2e-7387137923c8"}}}]}, {"uuid": "bc126c2c-755e-4200-8d8f-962a94855b9c", "name": "load_p1rlv135_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbdefe7a-517b-495b-88b8-dcf15a9429ff"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50f95d46-0ac6-48ff-95ad-00338df71ef2"}}}}, {"uuid": "9f3b6ec2-dfbd-409b-a2c6-525a9ff654ff", "name": "39164d37-47d5-414e-8a10-a40a4ab83b24_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.42648220197083947, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17627708866943506, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d0e4956c-feaf-42b5-9ee4-c963a2a26935", "name": "15277c3b-7fa8-4388-a600-0b7f97c905a4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9f3b6ec2-dfbd-409b-a2c6-525a9ff654ff"}}}]}, {"uuid": "2d231a9c-7512-4f43-8277-1487fc229652", "name": "load_p1rlv136_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b45d086e-8e0d-42f4-a8ec-6d3a9579a96b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d0e4956c-feaf-42b5-9ee4-c963a2a26935"}}}}, {"uuid": "fdafdf3b-73b3-453a-87c2-2df8084bb98c", "name": "ca06e9b0-4117-4eff-bf25-bbfe498d6009_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.42648220197083947, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17627708866943506, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9cc6a9b8-8464-4424-b3b3-4d2cc9d97dd5", "name": "25312fce-d271-4992-a5e5-ddb8d59e7ff5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fdafdf3b-73b3-453a-87c2-2df8084bb98c"}}}]}, {"uuid": "1cdcc87f-f562-47be-91b4-f48dd1775575", "name": "load_p1rlv136_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b45d086e-8e0d-42f4-a8ec-6d3a9579a96b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9cc6a9b8-8464-4424-b3b3-4d2cc9d97dd5"}}}}, {"uuid": "0086126c-4d2d-4fc7-96e6-03d8d4cac9d3", "name": "f3fd3a9b-7921-449c-8770-15e549537819_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7847716543397305, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8567239737527961, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "505c74a3-c96f-4c02-a72f-d0f90e0437a1", "name": "a5512df3-8486-4353-af08-2fc11ccb626e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0086126c-4d2d-4fc7-96e6-03d8d4cac9d3"}}}]}, {"uuid": "c16d5956-bcaf-4e19-bbb4-a2d9c7c50985", "name": "load_p1rlv137_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54ca5205-5b71-42f2-8e24-c24f768a7a5c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "505c74a3-c96f-4c02-a72f-d0f90e0437a1"}}}}, {"uuid": "db699610-605d-413c-8ff6-f42b1562e0cf", "name": "286e5f6e-1ae8-4f8b-8acf-22c703327965_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7847716543397305, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8567239737527961, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6a7d692c-a117-4247-8287-b3f354c302fd", "name": "bbcd4a4f-a0ec-4892-93b6-87e6bf5f4997", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "db699610-605d-413c-8ff6-f42b1562e0cf"}}}]}, {"uuid": "b741fa39-d83e-4937-81da-2c267cac540d", "name": "load_p1rlv137_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54ca5205-5b71-42f2-8e24-c24f768a7a5c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6a7d692c-a117-4247-8287-b3f354c302fd"}}}}, {"uuid": "682e5096-46cf-4550-a322-c4ab8b58f66e", "name": "fa81627e-9a5c-4990-b78c-b6a34af2247d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3464174292990054, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8802812503815668, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f4389e8d-94fe-424c-ab95-9398108a0c98", "name": "02f8a4fb-67f2-46db-a057-566bd62223f2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "682e5096-46cf-4550-a322-c4ab8b58f66e"}}}]}, {"uuid": "a13d6162-7194-4ef1-9525-14c7daa057bc", "name": "load_p1rlv138_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea9e5f8c-8477-403c-9d3a-911c4e5ab5c8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f4389e8d-94fe-424c-ab95-9398108a0c98"}}}}, {"uuid": "31687a1d-b0c0-4fdf-b82d-bc308aabefd0", "name": "177ce2f3-6ac7-4c15-946b-12bb54870dea_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3464174292990054, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8802812503815668, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "95e0385d-8d99-4303-b089-6f2829172f7e", "name": "2dc4c056-d7cb-4f5b-a146-5befc5393a1a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "31687a1d-b0c0-4fdf-b82d-bc308aabefd0"}}}]}, {"uuid": "dcd3190d-0b75-48da-8b22-cc7d18a61203", "name": "load_p1rlv138_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea9e5f8c-8477-403c-9d3a-911c4e5ab5c8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "95e0385d-8d99-4303-b089-6f2829172f7e"}}}}, {"uuid": "b1a1e4ef-f08c-4195-99b1-234afd20d768", "name": "d35c880e-0ed2-4c1d-a930-f6984f03b3be_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d041a1dd-add3-4622-b9a3-3318ab972cfa", "name": "785d81d9-4a00-4d38-8461-704019109825", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b1a1e4ef-f08c-4195-99b1-234afd20d768"}}}]}, {"uuid": "9d10a1c4-d3ce-4795-a27d-1d6c70a0f364", "name": "load_p1rlv139_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b515111-3455-471a-aba8-92c82624a195"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d041a1dd-add3-4622-b9a3-3318ab972cfa"}}}}, {"uuid": "659e1f70-3a5c-4fe3-b175-ae2b937d5072", "name": "72b548ea-22ba-43cf-8b60-272236c601e5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "315adfbb-45bd-4aef-b975-b33240c1baaa", "name": "1bc333f7-d58e-4446-a171-8fb28b2036bd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "659e1f70-3a5c-4fe3-b175-ae2b937d5072"}}}]}, {"uuid": "d2dc7c04-36f4-41ec-9710-1fc569efcafc", "name": "load_p1rlv139_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b515111-3455-471a-aba8-92c82624a195"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "315adfbb-45bd-4aef-b975-b33240c1baaa"}}}}, {"uuid": "034b2e6c-75c2-4ec8-b37f-f667c33a99c5", "name": "088bc71c-b927-42da-9b52-f7e65500ea96_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.209150400251685, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2205162973996855, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "19a5d21e-61b9-463f-9019-13b26647196e", "name": "d56465c5-95d2-4be6-bfed-60413c14803f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "034b2e6c-75c2-4ec8-b37f-f667c33a99c5"}}}]}, {"uuid": "5f355174-2450-47b3-8699-e6f5ab544c8c", "name": "load_p1rlv140_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47b7d9f8-ca72-4a77-af67-74ee561f7f10"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "19a5d21e-61b9-463f-9019-13b26647196e"}}}}, {"uuid": "63bb7c2e-c2b4-40b4-b982-f5fa68dd616f", "name": "a7a86684-abbb-4eba-bb58-2664751d69a4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.209150400251685, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2205162973996855, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "15829817-4b74-4da6-8886-2ceb190a7d6a", "name": "26b8d213-19be-48eb-9e30-43b201a201e2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "63bb7c2e-c2b4-40b4-b982-f5fa68dd616f"}}}]}, {"uuid": "078efe7b-e8c2-4b0a-8724-18637fa38f8e", "name": "load_p1rlv140_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47b7d9f8-ca72-4a77-af67-74ee561f7f10"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "15829817-4b74-4da6-8886-2ceb190a7d6a"}}}}, {"uuid": "eda14cb6-5a95-4051-932e-1aaf61b27387", "name": "d6dac862-178a-429b-b99c-fdc55e6ecf30_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.151480398016275, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.11399865992730775, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "44a09194-ef66-4ffc-878e-d75e35308de7", "name": "4ebb344d-82dc-499a-9c40-c415cfc56f7b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eda14cb6-5a95-4051-932e-1aaf61b27387"}}}]}, {"uuid": "fc3a2ef7-4d6c-4256-850a-721c0c740e0d", "name": "load_p1rlv141_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb69a6a9-3eaf-4fc3-82be-0eec77455a82"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "44a09194-ef66-4ffc-878e-d75e35308de7"}}}}, {"uuid": "38871f1f-85b5-4b3b-af00-f94e78fd4eae", "name": "f5a7f030-cd46-44b6-a68d-99662bdd96d6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.151480398016275, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.11399865992730775, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ae6826a1-1972-422c-8398-5a8baefac133", "name": "ad2ef29a-cada-4bf4-a441-2bfd7068ee86", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "38871f1f-85b5-4b3b-af00-f94e78fd4eae"}}}]}, {"uuid": "ca231060-9de7-45a2-b588-e95b9061ebb8", "name": "load_p1rlv141_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb69a6a9-3eaf-4fc3-82be-0eec77455a82"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ae6826a1-1972-422c-8398-5a8baefac133"}}}}, {"uuid": "11514d8b-42b8-44ec-b770-f820efbc3626", "name": "b3b92ae2-3d05-4a7c-b72e-47c331e7a3f2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9029063430901945, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8881818750925909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b0adad72-9bdc-41ec-8a01-baf64e8da41f", "name": "bee29b63-4f88-4222-881d-7ad9afaad9c8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "11514d8b-42b8-44ec-b770-f820efbc3626"}}}]}, {"uuid": "c9a36645-5b3b-40d0-853e-4c24719fea23", "name": "load_p1rlv143_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "46cd88d0-b2c4-492a-af3d-d9ae886d0089"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b0adad72-9bdc-41ec-8a01-baf64e8da41f"}}}}, {"uuid": "8e1d9cc7-4be8-4426-beb6-ad38017a7ab5", "name": "8e55faaf-86ba-45d3-9a60-33e353e2969a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9029063430901945, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8881818750925909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b5c00744-639c-41ea-96ca-c1f09800fc3a", "name": "66ff36d7-5b31-4475-84ee-e223b11c1d90", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8e1d9cc7-4be8-4426-beb6-ad38017a7ab5"}}}]}, {"uuid": "b13f3e78-16f0-46ea-a28a-6bd223312662", "name": "load_p1rlv143_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "46cd88d0-b2c4-492a-af3d-d9ae886d0089"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b5c00744-639c-41ea-96ca-c1f09800fc3a"}}}}, {"uuid": "6efba862-2084-4197-8842-7a4e3e7cbe55", "name": "ca51752d-e464-48b4-89bb-3cab4889764a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9024769844937937, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4778358547008617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4618b6bb-3217-4c40-81e5-337da883d284", "name": "d6d818ce-0039-4dc7-92b2-95d506c66f3d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6efba862-2084-4197-8842-7a4e3e7cbe55"}}}]}, {"uuid": "6dfbe3aa-d122-4dd0-adae-a501ba9ce94f", "name": "load_p1rlv144_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b7dbf54-f6bc-4e20-b2f3-8c63a44dd993"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4618b6bb-3217-4c40-81e5-337da883d284"}}}}, {"uuid": "9b3d7385-18b7-4c12-87d4-28509ac71622", "name": "8b41385c-d319-435b-878e-1abaaf86169d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9024769844937937, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4778358547008617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cfddae17-0b75-403e-8c4b-abf94636a6da", "name": "bd484a3e-574e-4959-9058-98b297b870ba", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9b3d7385-18b7-4c12-87d4-28509ac71622"}}}]}, {"uuid": "651d58ec-8f41-4a45-87bf-325c1f4cd4ab", "name": "load_p1rlv144_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b7dbf54-f6bc-4e20-b2f3-8c63a44dd993"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cfddae17-0b75-403e-8c4b-abf94636a6da"}}}}, {"uuid": "596e3b96-2e23-4f01-90df-cd04c0f0f94c", "name": "a681cdc9-4b50-46b7-8c08-2d8bffbb7144_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5478654763148745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5646840796232575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "64174510-2d82-4a24-91df-ec21ad651c75", "name": "94f59b95-5d40-449e-982f-797659492681", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "596e3b96-2e23-4f01-90df-cd04c0f0f94c"}}}]}, {"uuid": "2c8ea63a-1b5f-4324-8f57-3190d9421025", "name": "load_p1rlv145_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1704e67-dfa3-4a6b-a3f4-7ebba9d27537"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "64174510-2d82-4a24-91df-ec21ad651c75"}}}}, {"uuid": "26401bca-ca42-4b35-96cb-c083a9c82b1e", "name": "40b6c346-3a2f-4b29-a7b6-747e501f9941_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5478654763148745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5646840796232575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c752fc03-cc98-431f-bdef-07b64f2c5114", "name": "7fd9d5e3-d134-4162-8ad5-5b57c4b8eb78", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "26401bca-ca42-4b35-96cb-c083a9c82b1e"}}}]}, {"uuid": "033e9386-a8ca-41a0-b92b-a0e2abb19756", "name": "load_p1rlv145_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1704e67-dfa3-4a6b-a3f4-7ebba9d27537"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c752fc03-cc98-431f-bdef-07b64f2c5114"}}}}, {"uuid": "b304661b-8f12-449a-8f41-f02a8a8c80e2", "name": "9e58965c-d189-4f80-86fe-7f5fb1bf3fcf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8309189378455104, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6069744647018672, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a64c60f-711f-4c47-ad03-c64950c901a1", "name": "2e28f36a-4df6-4074-806a-a131dde98fd9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b304661b-8f12-449a-8f41-f02a8a8c80e2"}}}]}, {"uuid": "b2e7ecf7-0e4c-444d-8662-2650fcbbdf78", "name": "load_p1rlv146_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da2538bd-189b-4699-823b-ed459d94b422"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a64c60f-711f-4c47-ad03-c64950c901a1"}}}}, {"uuid": "c0bafccd-dcf8-4967-8689-6d2494d0b36c", "name": "2c66c959-d921-48eb-b2fe-7f3c076980f0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8309189378455104, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6069744647018672, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6fdf8d05-e64c-493f-945d-164885fb3387", "name": "fd78a750-5fc4-431b-bf2f-b6cdba25cfd6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c0bafccd-dcf8-4967-8689-6d2494d0b36c"}}}]}, {"uuid": "23482389-4769-43fa-8b5f-093a6f1dbc66", "name": "load_p1rlv146_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da2538bd-189b-4699-823b-ed459d94b422"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6fdf8d05-e64c-493f-945d-164885fb3387"}}}}, {"uuid": "d96d1306-0ca2-444f-bd3a-14e7ce69c39c", "name": "79ef7648-0e4f-47f3-9552-070c1daf8b7e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.3355603190645935, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9435041304985261, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4e188817-c68e-43ff-b1b3-d8b89b6313f8", "name": "2e1300a2-b142-4cf7-b428-44ae641f3b33", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d96d1306-0ca2-444f-bd3a-14e7ce69c39c"}}}]}, {"uuid": "44fd75f0-0108-48e9-91b3-66e8bd787b59", "name": "load_p1rlv147_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "070d9a60-c6f2-424c-bd0f-66c52d349f0c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4e188817-c68e-43ff-b1b3-d8b89b6313f8"}}}}, {"uuid": "4f99e19b-0c10-4aa1-a8d2-49724a8051ad", "name": "6d8d7835-2274-4924-9a05-990a5b79ed12_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.3355603190645935, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9435041304985261, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "56054ae6-3682-47ac-a664-23bb779230da", "name": "2dbd413d-f2d8-468d-9705-7dd87674f442", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4f99e19b-0c10-4aa1-a8d2-49724a8051ad"}}}]}, {"uuid": "bcbb05e5-afc4-4792-87d5-52bea1b4b377", "name": "load_p1rlv147_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "070d9a60-c6f2-424c-bd0f-66c52d349f0c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "56054ae6-3682-47ac-a664-23bb779230da"}}}}, {"uuid": "58883f3e-fe3f-4f4a-b34b-a98fbc741f50", "name": "f46cb48f-eaaa-4ffb-9352-6dc4011d0fbb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8322096344455547, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7991596594888891, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "467b71c4-89b2-41bb-a169-4113dd36049d", "name": "2f7cc6c9-2406-41b0-a256-0bf75d1c8276", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58883f3e-fe3f-4f4a-b34b-a98fbc741f50"}}}]}, {"uuid": "6592f31a-023d-4bb6-bff2-43300edf4703", "name": "load_p1rlv148_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa8af0a4-4d55-41e4-83d1-4fe349920e38"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "467b71c4-89b2-41bb-a169-4113dd36049d"}}}}, {"uuid": "f3b31322-4a81-4bd1-81b9-bcc2afe6fdf5", "name": "4dffbdd2-5c5c-4770-bd8d-35347cb4a8c6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8322096344455547, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7991596594888891, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b2180f75-44f0-42d8-88f3-f1346b5158b9", "name": "abba6f94-a44b-4def-8331-63b5e15689d0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f3b31322-4a81-4bd1-81b9-bcc2afe6fdf5"}}}]}, {"uuid": "222251ff-23fc-4c53-b67b-5d791152038f", "name": "load_p1rlv148_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa8af0a4-4d55-41e4-83d1-4fe349920e38"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b2180f75-44f0-42d8-88f3-f1346b5158b9"}}}}, {"uuid": "b18a0e35-3710-4ac6-8659-b140bcddb054", "name": "0f329b93-21bb-46c9-81b6-04efa26cb4d7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4856814769108864, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8267323554826451, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c299fdab-1be2-44cc-96e2-6818b024cf1a", "name": "7a46dd14-b0c7-4773-90e5-a77125b014aa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b18a0e35-3710-4ac6-8659-b140bcddb054"}}}]}, {"uuid": "7d8e659d-c80b-4311-97a0-4bccb4c72934", "name": "load_p1rlv149_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "063e89ea-6dd0-404f-abfb-21686f3041ed"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c299fdab-1be2-44cc-96e2-6818b024cf1a"}}}}, {"uuid": "d9f6edac-f43c-41d2-9855-3e5d321a5557", "name": "c29d21b1-bfc1-401b-98a6-fdb5f43c054f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4856814769108864, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8267323554826451, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c7ac34c1-7a2f-4670-8fc2-8f72b68d431a", "name": "be672881-04e7-4295-b56d-1fd88d691219", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d9f6edac-f43c-41d2-9855-3e5d321a5557"}}}]}, {"uuid": "9b6cbfe0-93bd-470e-a7c2-b85265e317a0", "name": "load_p1rlv149_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "063e89ea-6dd0-404f-abfb-21686f3041ed"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c7ac34c1-7a2f-4670-8fc2-8f72b68d431a"}}}}, {"uuid": "2755d3e5-9a94-44af-9a22-f04a395f82bd", "name": "77049928-0e3f-4ffa-a8eb-edc8a66ec445_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4363904318707768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7717292253609904, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6bf52870-b994-4ac6-a78e-f09d89990a8e", "name": "7d6ae7c1-3b27-41a7-bd5b-17fbd7f49a36", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2755d3e5-9a94-44af-9a22-f04a395f82bd"}}}]}, {"uuid": "c9162abe-7b46-4442-b723-313a2f140b94", "name": "load_p1rlv150_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b9979ec-4e43-4feb-a617-28191e9dd9d8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6bf52870-b994-4ac6-a78e-f09d89990a8e"}}}}, {"uuid": "cc94c4fb-e6d2-4258-99f2-80cc480e81f8", "name": "56adb619-83e9-403c-b508-c29461a2acdf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4363904318707768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7717292253609904, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "923dac6e-dac9-4b6a-88b9-f90ce0af4d15", "name": "12e1cf39-01d8-4998-9719-5ff883dbd7c5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cc94c4fb-e6d2-4258-99f2-80cc480e81f8"}}}]}, {"uuid": "38d8ebb4-802c-4053-9ffc-dad485aa76c3", "name": "load_p1rlv150_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b9979ec-4e43-4feb-a617-28191e9dd9d8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "923dac6e-dac9-4b6a-88b9-f90ce0af4d15"}}}}, {"uuid": "4a96dd5c-c1cf-4bda-8faa-6c177cac16a0", "name": "6cdc4319-9a33-4da3-a140-3084bd8675d2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.371919551924291, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7891526087442801, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e6169458-cf82-4d24-9754-3f8c1bd6a7fc", "name": "045e2802-f6e2-4e20-8056-bdb6b7c4142f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4a96dd5c-c1cf-4bda-8faa-6c177cac16a0"}}}]}, {"uuid": "0cda9978-67ba-4878-a11b-9c6683e1b644", "name": "load_p1rlv151_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "345b5c48-cd35-418e-bc08-50c06f5dff09"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e6169458-cf82-4d24-9754-3f8c1bd6a7fc"}}}}, {"uuid": "fd0d566a-eb29-49c1-b499-db0fef89ceeb", "name": "410cbe2a-d7b3-412a-b5a5-1d5e77cbc28c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.371919551924291, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7891526087442801, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "24d62fae-b96b-411a-a99a-e92cb4e74a46", "name": "bb1f18f6-0cad-4534-b8bd-2d97729aef38", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fd0d566a-eb29-49c1-b499-db0fef89ceeb"}}}]}, {"uuid": "43d28bc8-e7f1-4742-8311-292f1796ff7c", "name": "load_p1rlv151_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "345b5c48-cd35-418e-bc08-50c06f5dff09"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "24d62fae-b96b-411a-a99a-e92cb4e74a46"}}}}, {"uuid": "bb9f90a6-0e2c-480b-abaf-2caaf59df40d", "name": "b55ad8a0-3c28-4dad-be50-b52c8aad5aef_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1381537134701794, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42848704523913217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6aa1373f-1958-42b9-8eb0-2aa8619f5abb", "name": "96966198-f951-452f-9a42-229b7fd330b1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bb9f90a6-0e2c-480b-abaf-2caaf59df40d"}}}]}, {"uuid": "1a727775-9d19-408b-aa4a-28ef8bac6e71", "name": "load_p1rlv152_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25b891ce-797a-4a4d-b664-4225fba806c4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6aa1373f-1958-42b9-8eb0-2aa8619f5abb"}}}}, {"uuid": "50d91c7a-0fab-42dd-9308-c8d005ab6688", "name": "351c5236-9e35-4471-833c-dc9da4e7e306_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1381537134701794, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42848704523913217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4cb66431-8190-4793-9e90-23f1cdb1cb25", "name": "7f716e77-1e2b-4a56-95cb-dc1a96d25136", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "50d91c7a-0fab-42dd-9308-c8d005ab6688"}}}]}, {"uuid": "21fe823b-b24d-4c2c-a164-eb7bf5f9c199", "name": "load_p1rlv152_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25b891ce-797a-4a4d-b664-4225fba806c4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4cb66431-8190-4793-9e90-23f1cdb1cb25"}}}}, {"uuid": "ad038307-bf63-4325-aaf3-7073f33fc11c", "name": "41412b4d-fb58-44a6-af9d-eac87b314ace_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.567401274738218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6497123013243786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9589c15d-3d6c-4085-a001-b653159fda79", "name": "a02eb120-8919-40e8-9966-15fa07f620d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ad038307-bf63-4325-aaf3-7073f33fc11c"}}}]}, {"uuid": "3ad36ef3-8756-4f87-937c-8b411a17f018", "name": "load_p1rlv153_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ebbe09dd-7560-4eff-9e32-803f14b4ce7c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9589c15d-3d6c-4085-a001-b653159fda79"}}}}, {"uuid": "3d6b9794-cc04-4a3c-8508-8c264e5770c7", "name": "b1908562-73cc-4fb3-aad9-109c6f7b8693_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.567401274738218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6497123013243786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "28f9d670-2046-4464-aebf-afde5cb96ba4", "name": "c59fabc3-bbb0-4ff5-99d0-a1e491b30a5e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3d6b9794-cc04-4a3c-8508-8c264e5770c7"}}}]}, {"uuid": "88e1d099-0fe2-4cf9-9696-2cd72fa5929d", "name": "load_p1rlv153_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ebbe09dd-7560-4eff-9e32-803f14b4ce7c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "28f9d670-2046-4464-aebf-afde5cb96ba4"}}}}, {"uuid": "ff01f4eb-995f-4752-b365-bba2b9223d49", "name": "4dc3d221-3521-416a-b5e5-46ff24f0c3e1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6235247805381197, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5206515777483778, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "47d88b93-6ce7-4903-bac2-9c34abcdfe9e", "name": "de3bf5d6-9721-4ffb-96a8-2dde7c116d90", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ff01f4eb-995f-4752-b365-bba2b9223d49"}}}]}, {"uuid": "fe71efd1-7d64-4c4a-ac74-446d584f4c5e", "name": "load_p1rlv154_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ccdfbc7-d3a6-4f74-ad32-25ff11a2e3b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "47d88b93-6ce7-4903-bac2-9c34abcdfe9e"}}}}, {"uuid": "0614c34a-114c-40d2-a8c2-2d1a046eeed4", "name": "99ae88cc-c8fe-4c25-9c77-2dbe4f065ce2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6235247805381197, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5206515777483778, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "addce10f-e9ee-486f-b31b-e941253493a8", "name": "b453f214-b5c5-42a8-837e-0a729f59b610", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0614c34a-114c-40d2-a8c2-2d1a046eeed4"}}}]}, {"uuid": "8c98171c-35a4-4280-bc3b-6e54c2785507", "name": "load_p1rlv154_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ccdfbc7-d3a6-4f74-ad32-25ff11a2e3b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "addce10f-e9ee-486f-b31b-e941253493a8"}}}}, {"uuid": "5fd7bfc3-e074-4c73-af9b-c9afd6066292", "name": "551775ff-9f39-42b0-830d-e330ac2d1791_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.108706484347092, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9298438232381894, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f6a57a7d-a667-482a-be6f-e450371abb29", "name": "aeea7305-281e-4470-af56-a22592c1c7ff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5fd7bfc3-e074-4c73-af9b-c9afd6066292"}}}]}, {"uuid": "18f9ee3a-9c84-4710-beab-a5bb978ec532", "name": "load_p1rlv155_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2452d5af-5aba-4d4b-8cd9-27a95fe6b34d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f6a57a7d-a667-482a-be6f-e450371abb29"}}}}, {"uuid": "3a47ae95-d7cb-4523-93c2-230fb065d89b", "name": "c95d57ba-4cf0-4346-bd63-3f17baf8f9cb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.108706484347092, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9298438232381894, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e6a822a7-b8d1-4bb4-9a75-ab11afaa184f", "name": "d725a57f-a94b-41c7-a169-d697f57dadb1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3a47ae95-d7cb-4523-93c2-230fb065d89b"}}}]}, {"uuid": "8e9ded2b-34fc-4efa-8c3c-dca36a27429a", "name": "load_p1rlv155_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2452d5af-5aba-4d4b-8cd9-27a95fe6b34d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e6a822a7-b8d1-4bb4-9a75-ab11afaa184f"}}}}, {"uuid": "948fd41c-89a2-42c7-af9e-4063c6d0b180", "name": "fc5973c9-b174-43c4-8cdf-7a83995d7b04_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7537427041030689, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.37349948863112625, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "abf8107a-a30b-4316-a765-541a893ce591", "name": "c1c669b4-f5a0-43c9-968d-302e6cb121e3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "948fd41c-89a2-42c7-af9e-4063c6d0b180"}}}]}, {"uuid": "5d8cfb02-36f5-4d97-980b-1c7bedf17ccf", "name": "load_p1rlv156_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f607e6b-9540-4845-9f0c-6c334eb0e807"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "abf8107a-a30b-4316-a765-541a893ce591"}}}}, {"uuid": "935ef1c3-72e1-436e-bc15-f545f6b403df", "name": "5191cadc-6d3e-48d3-8e78-1380f62e6742_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7537427041030689, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.37349948863112625, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82073bd9-631c-47e5-9919-c1b48349e72d", "name": "469bcafc-5ecb-4cc8-890e-900f450020c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "935ef1c3-72e1-436e-bc15-f545f6b403df"}}}]}, {"uuid": "9db2b8c0-d340-498e-859f-41389b498e69", "name": "load_p1rlv156_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f607e6b-9540-4845-9f0c-6c334eb0e807"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "82073bd9-631c-47e5-9919-c1b48349e72d"}}}}, {"uuid": "bbb9af72-1b21-4719-acda-ff7ca257537b", "name": "fdb83a04-3f11-4a69-8f2d-ca418085afcd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.095937077188644, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9158391685680531, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10e19920-3702-415e-83da-bc6eb9517f3d", "name": "78eb2ff1-0b89-4b2a-85b9-3fe469d614d9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bbb9af72-1b21-4719-acda-ff7ca257537b"}}}]}, {"uuid": "5f7c3981-32f3-4b90-bed6-25b9d01fc927", "name": "load_p1rlv157_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4355a473-4643-4f72-afe8-80ce773ca8e8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10e19920-3702-415e-83da-bc6eb9517f3d"}}}}, {"uuid": "175e92fa-a479-4df5-b9c0-237f7d031d69", "name": "3d0ce575-376f-4ba3-a146-4f3a1499a5e3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.095937077188644, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9158391685680531, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7a5f84b4-faf1-4cf8-8940-65f8f657c018", "name": "2c3d94ef-3441-4046-9dc3-92fa55fe52a1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "175e92fa-a479-4df5-b9c0-237f7d031d69"}}}]}, {"uuid": "fbe3ca78-571d-4ae4-860f-991921cbbcaf", "name": "load_p1rlv157_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4355a473-4643-4f72-afe8-80ce773ca8e8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7a5f84b4-faf1-4cf8-8940-65f8f657c018"}}}}, {"uuid": "8cdd07ea-28f2-4a13-9de0-e26993ff5341", "name": "4ee96c19-3806-4064-94b6-eeb44c18e551_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8840297592093247, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9532534150802011, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "899d4299-2a0e-4ae5-b0b9-1390e0fcc535", "name": "d78e16a0-bffa-49d7-ac9b-8b36e97e82d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8cdd07ea-28f2-4a13-9de0-e26993ff5341"}}}]}, {"uuid": "8de3c047-03a9-4aba-9e64-f6ab42a642a6", "name": "load_p1rlv158_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1cd7284-17fb-4382-a29d-dd8c5bfd7541"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "899d4299-2a0e-4ae5-b0b9-1390e0fcc535"}}}}, {"uuid": "0c8d86db-65a9-4c7d-af73-c853594251e4", "name": "3eb1bae5-9be0-415d-844d-fc6a79d0ac7e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8840297592093247, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9532534150802011, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "778bb6f1-53ee-4071-b98f-50c7a63b20a1", "name": "4146d0a9-becf-474c-90ce-ea5b8fc8844e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0c8d86db-65a9-4c7d-af73-c853594251e4"}}}]}, {"uuid": "e41e26d9-4dcc-4f50-ac1a-dc1a9f2fdeed", "name": "load_p1rlv158_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1cd7284-17fb-4382-a29d-dd8c5bfd7541"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "778bb6f1-53ee-4071-b98f-50c7a63b20a1"}}}}, {"uuid": "d68b2e1c-0cbf-46c4-913b-f7d400006ae7", "name": "9f845cf9-8a36-4ec0-bba1-3983a908f7e8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.374654272561421, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4772638197977597, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e6f5f0bb-c625-4ae5-80f5-ea8be9ed6188", "name": "27cc8d66-ef3e-4ce0-bd01-0b412d29c7b7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d68b2e1c-0cbf-46c4-913b-f7d400006ae7"}}}]}, {"uuid": "83135160-8d59-48d8-89f3-a13a2e5a666d", "name": "load_p1rlv159_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0ae6c02-c29e-4bf9-b1d4-ecc7e37e7de2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e6f5f0bb-c625-4ae5-80f5-ea8be9ed6188"}}}}, {"uuid": "3cfea8c2-b638-47d9-b2ac-ef32e676f050", "name": "1b8759f5-240f-4f14-bb73-b120b24050f6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.374654272561421, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4772638197977597, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c5d16f5c-a56f-4d89-9ba4-0e87a25ae1e4", "name": "9632e604-abee-4381-a8da-ef8a40bb3c5d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3cfea8c2-b638-47d9-b2ac-ef32e676f050"}}}]}, {"uuid": "3c29eda9-ab0f-4b5b-998f-68e75fdc6376", "name": "load_p1rlv159_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0ae6c02-c29e-4bf9-b1d4-ecc7e37e7de2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c5d16f5c-a56f-4d89-9ba4-0e87a25ae1e4"}}}}, {"uuid": "b9ddc7cb-eb34-46b9-8a35-4504b55c290c", "name": "7428b4e2-67cc-42de-88ea-cbee112a2d17_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.442421826038779, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9571745396829384, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6c0b14c3-394b-4868-b1d3-5d7e95265052", "name": "bb27f7e2-8d35-46f2-a528-59ef9a686b87", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b9ddc7cb-eb34-46b9-8a35-4504b55c290c"}}}]}, {"uuid": "f9560b22-0982-4d00-8b31-a029346a264e", "name": "load_p1rlv160_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd2fae5a-e5dd-4ad4-8acc-422de00ae83e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6c0b14c3-394b-4868-b1d3-5d7e95265052"}}}}, {"uuid": "af343575-9b10-43f2-9a7b-35f179fb9685", "name": "2970a6c2-819e-455d-a867-daa7338e6234_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.442421826038779, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9571745396829384, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c5f5f382-7b6d-4bae-a150-b970b5ee303f", "name": "ea134b02-0b2f-4a4f-be02-7a0cd5401977", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "af343575-9b10-43f2-9a7b-35f179fb9685"}}}]}, {"uuid": "8133c7b7-4525-4ca0-a609-363f6efc7d54", "name": "load_p1rlv160_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd2fae5a-e5dd-4ad4-8acc-422de00ae83e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c5f5f382-7b6d-4bae-a150-b970b5ee303f"}}}}, {"uuid": "328d8c3e-0611-4a1e-b691-dc74728b29c5", "name": "af682978-efe2-47c9-a254-c3c11fc0d851_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0ff97ff9-a544-4896-8d12-a2f3de1ce723", "name": "589c8a5d-0a70-4a9c-9b5b-8a80a9d0e905", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "328d8c3e-0611-4a1e-b691-dc74728b29c5"}}}]}, {"uuid": "0628e2d9-5b47-44ae-87b3-22c5f8b928e3", "name": "load_p1rlv161_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4842819e-3f17-47da-a8bf-c3402c3c00b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0ff97ff9-a544-4896-8d12-a2f3de1ce723"}}}}, {"uuid": "8a242f35-2441-445f-8acf-0276263fed46", "name": "25040100-e180-4f0b-8556-982cff6f28b8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bfc0ef6d-9d70-45f9-b448-da730be6008c", "name": "195665b6-661d-4ba2-b416-f11523a8957c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a242f35-2441-445f-8acf-0276263fed46"}}}]}, {"uuid": "9f3ac376-58ea-4e67-860a-22cb60ee101b", "name": "load_p1rlv161_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4842819e-3f17-47da-a8bf-c3402c3c00b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bfc0ef6d-9d70-45f9-b448-da730be6008c"}}}}, {"uuid": "0c866a74-80b4-4de8-ab0f-8af6d5e99cc7", "name": "0d2de203-31e0-414e-86dd-b5ecdf23e2ed_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8374792851175116, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3203908676737591, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2dd7a99d-e8de-47c1-9d13-4bf7dd8f3b77", "name": "9df39120-b9c3-4747-bddc-d26981985449", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0c866a74-80b4-4de8-ab0f-8af6d5e99cc7"}}}]}, {"uuid": "cdccd113-7867-400e-9bfc-673b6504e025", "name": "load_p1rlv162_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3fcd1ee-e6e0-4ca3-aacf-cc527b07482a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2dd7a99d-e8de-47c1-9d13-4bf7dd8f3b77"}}}}, {"uuid": "d2422cd1-af9d-45dc-8c9c-7288cfc5a26b", "name": "bde66f82-50c0-41b3-b680-4d7bddd49d6e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8374792851175116, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3203908676737591, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0f1052fb-c159-459d-bf3e-737a269fb736", "name": "d2e1b2a4-fcf6-4c91-a810-c2e59000da86", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d2422cd1-af9d-45dc-8c9c-7288cfc5a26b"}}}]}, {"uuid": "b329cd69-c9b0-4878-ac79-27870fdbbe7e", "name": "load_p1rlv162_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3fcd1ee-e6e0-4ca3-aacf-cc527b07482a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0f1052fb-c159-459d-bf3e-737a269fb736"}}}}, {"uuid": "96517525-e2c4-4d6d-aa67-3c78f0ede687", "name": "6c840f55-ebfd-43cc-9769-381ffbf540d5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.255903801273714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9789336651099453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f698c194-b969-456c-9959-4ebbdb8258f3", "name": "98aae7db-d220-421a-acee-cdddcf98741b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "96517525-e2c4-4d6d-aa67-3c78f0ede687"}}}]}, {"uuid": "008c43f1-f5ea-44de-b929-426e8ea6a8ac", "name": "load_p1rlv163_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "471bad88-4514-4b02-aa1a-1d2aaa15557f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f698c194-b969-456c-9959-4ebbdb8258f3"}}}}, {"uuid": "156e6d01-cde8-4bc7-a0cc-ba85375c0343", "name": "0dd99461-0697-4bf2-90a3-f24b43c866bf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.255903801273714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9789336651099453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10d3b8af-7878-4ddd-a72f-04d0d6d5de38", "name": "9fe24db1-0e1e-490c-8da4-76b48f4d9ed3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "156e6d01-cde8-4bc7-a0cc-ba85375c0343"}}}]}, {"uuid": "b5ba124b-48a8-4202-9869-3c0a2845cefa", "name": "load_p1rlv163_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "471bad88-4514-4b02-aa1a-1d2aaa15557f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10d3b8af-7878-4ddd-a72f-04d0d6d5de38"}}}}, {"uuid": "ae092096-ac18-4e26-8ec9-767664b6f311", "name": "469ae3f3-b681-4f98-a225-2dfd2453a804_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.634023352191214, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2934174607236286, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "11d28751-2dc2-4643-ade5-056105ccf36c", "name": "0b58701e-29db-4654-93f6-13763353b25f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ae092096-ac18-4e26-8ec9-767664b6f311"}}}]}, {"uuid": "b4e237d5-30ca-442d-8332-301533b55a01", "name": "load_p1rlv164_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61460072-bdc5-4a70-96fa-8ecfa71623f4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "11d28751-2dc2-4643-ade5-056105ccf36c"}}}}, {"uuid": "b59962b8-410d-4873-8558-4dbe02ecb8fe", "name": "a0671619-9046-42c9-b892-98a56904909a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.634023352191214, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2934174607236286, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dc46ae19-b1eb-4477-87fb-ee2ba7499455", "name": "154e2be4-cb1f-478b-9e94-8f93b38d66c4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b59962b8-410d-4873-8558-4dbe02ecb8fe"}}}]}, {"uuid": "1b646ba1-bbb4-4502-b283-b240fdd81ce4", "name": "load_p1rlv164_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61460072-bdc5-4a70-96fa-8ecfa71623f4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dc46ae19-b1eb-4477-87fb-ee2ba7499455"}}}}, {"uuid": "bb4fa101-0970-45f9-a5db-ebad81aacb1c", "name": "8361d8ec-a547-4a5a-8787-e617c97ed8fb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.916354724025409, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9016755043678467, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3f4de5dd-749e-4e87-909a-e035a519fcdd", "name": "cc92d500-45e7-42e1-ae9b-13d8bb2f2fff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bb4fa101-0970-45f9-a5db-ebad81aacb1c"}}}]}, {"uuid": "0b35ffa2-4fa3-4ab2-84fa-08aaa61760c4", "name": "load_p1rlv165_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e7880c9-0932-4395-abf9-2274e400f280"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3f4de5dd-749e-4e87-909a-e035a519fcdd"}}}}, {"uuid": "d3f6d1d9-b892-4800-b2a5-7dad65648d40", "name": "96e6e68a-0043-4f91-9a2a-5b6b8b9aa970_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.916354724025409, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9016755043678467, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1d03c60f-63b8-4b5a-baba-e7e71a7e9690", "name": "ce24492e-0581-4b7b-918c-0c97ae277ba3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d3f6d1d9-b892-4800-b2a5-7dad65648d40"}}}]}, {"uuid": "468330c1-1a98-49d0-9b35-871faab87fbc", "name": "load_p1rlv165_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e7880c9-0932-4395-abf9-2274e400f280"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1d03c60f-63b8-4b5a-baba-e7e71a7e9690"}}}}, {"uuid": "768dc0db-9dfb-47b2-aac9-7217b1b0cbee", "name": "dc3081f4-2919-49bb-96a1-2f070a62ebc3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0137187800791063, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5284248988065299, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d9c6e84e-8f73-401c-88e7-e518034cdd97", "name": "4934d0b2-27f2-4f83-a544-8afa0eb732ae", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "768dc0db-9dfb-47b2-aac9-7217b1b0cbee"}}}]}, {"uuid": "0c371311-d835-4725-93c2-38caf4340198", "name": "load_p1rlv166_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21d333f7-7426-4fa6-8ab2-c6118055ece1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d9c6e84e-8f73-401c-88e7-e518034cdd97"}}}}, {"uuid": "085d4979-f0e8-4a81-b766-4edceb93e79e", "name": "bf77bda4-8aa9-4eba-89dd-84980b634d82_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0137187800791063, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5284248988065299, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b0114f8e-42b3-4cf6-bf82-0b5a74d34435", "name": "585e8691-2f0c-4b61-84c7-c44b11f02892", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "085d4979-f0e8-4a81-b766-4edceb93e79e"}}}]}, {"uuid": "4842b8c9-483a-4000-b8e4-e92115d3362f", "name": "load_p1rlv166_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21d333f7-7426-4fa6-8ab2-c6118055ece1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b0114f8e-42b3-4cf6-bf82-0b5a74d34435"}}}}, {"uuid": "e3d3f347-2cc5-4163-b195-f4feba41a7fd", "name": "76df4f4c-e521-4730-8e19-8b809222dc22_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.438316346451239, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6915244213249778, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bad3c5a9-944e-4467-ae32-a39f8d2467de", "name": "98d01b2b-b1f1-4250-9f1d-41f70ff5d409", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e3d3f347-2cc5-4163-b195-f4feba41a7fd"}}}]}, {"uuid": "edf53ba9-4c8d-48d7-8acc-70d10e07dd76", "name": "load_p1rlv167_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5187e006-621e-4c15-9604-0272ae62887c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bad3c5a9-944e-4467-ae32-a39f8d2467de"}}}}, {"uuid": "f4199876-e02c-443b-8a34-a7b5569f45be", "name": "52482e87-111f-48b8-acd8-e110e76daa7d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.438316346451239, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6915244213249778, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "549f4461-fd8e-4e37-b9ef-b0d574c9ce4d", "name": "793f7997-5e15-45b1-9c9c-14738a369d89", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f4199876-e02c-443b-8a34-a7b5569f45be"}}}]}, {"uuid": "c9d4f26a-59c2-47b0-82c3-cad585ad2f67", "name": "load_p1rlv167_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5187e006-621e-4c15-9604-0272ae62887c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "549f4461-fd8e-4e37-b9ef-b0d574c9ce4d"}}}}, {"uuid": "8214ae9e-a98a-47c7-bf7a-310a375c354b", "name": "d0eb3fa8-a282-44f2-8e59-84f3c3ccbabd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.639612501586281, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0977377571892493, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6742fd24-2bc0-431d-b30d-4dc763353622", "name": "ef806c3e-41af-4e54-9db4-fd35effb1c39", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8214ae9e-a98a-47c7-bf7a-310a375c354b"}}}]}, {"uuid": "9cf5e44e-7289-461c-87bd-47979c4da230", "name": "load_p1rlv168_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "470fe3ed-5b24-438a-ba6d-cdd9f774e5ad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6742fd24-2bc0-431d-b30d-4dc763353622"}}}}, {"uuid": "3cb772b7-4657-4d8c-b525-85caf30002e2", "name": "166a84a5-46bf-463f-a30d-ac639c12ef84_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.639612501586281, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0977377571892493, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1a1b7a21-7a66-4d44-a8a0-09649c122699", "name": "3cef0015-9633-4bbc-97cd-151780b2104d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3cb772b7-4657-4d8c-b525-85caf30002e2"}}}]}, {"uuid": "6cab2d7f-7acf-4f13-a544-9b4d10e51b6e", "name": "load_p1rlv168_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "470fe3ed-5b24-438a-ba6d-cdd9f774e5ad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1a1b7a21-7a66-4d44-a8a0-09649c122699"}}}}, {"uuid": "383399fd-31e7-4be4-99a8-6525097749ec", "name": "43b935d3-1a10-4adf-9410-46944594ccb7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.684904254134122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42635901069761617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f44b0661-5eed-4671-8837-51e4c5c01de3", "name": "d59b11a3-8cb6-49c5-95c5-60f8d1118f4b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "383399fd-31e7-4be4-99a8-6525097749ec"}}}]}, {"uuid": "1fd860c2-0753-45b8-baa9-3dc334d13763", "name": "load_p1rlv169_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e326756-7ead-4099-a065-9f2de5693197"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f44b0661-5eed-4671-8837-51e4c5c01de3"}}}}, {"uuid": "eeae9ebe-ad30-4b1e-b628-12e620aa68ec", "name": "3718c088-26e2-46ec-8ae8-2a1e26017e5f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.684904254134122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42635901069761617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fb2e612d-b1e6-4bc5-984a-fa6fe8fb9df5", "name": "2772f810-9754-4bd1-9c53-5e888bfd626a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eeae9ebe-ad30-4b1e-b628-12e620aa68ec"}}}]}, {"uuid": "9dc019fb-8428-44bd-a4e0-82641341dbcd", "name": "load_p1rlv169_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e326756-7ead-4099-a065-9f2de5693197"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fb2e612d-b1e6-4bc5-984a-fa6fe8fb9df5"}}}}, {"uuid": "1bd5db0e-8d36-4d2c-b7c0-993a45f5424c", "name": "c90b3a0a-1417-4e01-974d-e7498f6e4231_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7812856221781264, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.29493523962554685, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c16e7813-54ab-4d3e-b29f-e5b94c25edef", "name": "91b96749-f6a7-4aaa-8ef1-27ee7f1d7098", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1bd5db0e-8d36-4d2c-b7c0-993a45f5424c"}}}]}, {"uuid": "4b2fd52a-2379-40cc-b0e7-5233f221bf47", "name": "load_p1rlv170_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f7dbd18-1cbe-49d3-b490-3c46cf8e37f1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c16e7813-54ab-4d3e-b29f-e5b94c25edef"}}}}, {"uuid": "59335f20-1ff3-4163-8844-d0bccb5c1dd8", "name": "fd8c620e-38b3-4a2f-8207-a0ec2ba4c534_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7812856221781264, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.29493523962554685, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c7a14033-b9a3-4231-8824-61308ee49db0", "name": "ed26bab6-3b3c-4663-8439-73d41ffca540", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "59335f20-1ff3-4163-8844-d0bccb5c1dd8"}}}]}, {"uuid": "0b0521c1-45dd-4a1f-8d44-d93a0eaf0b10", "name": "load_p1rlv170_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f7dbd18-1cbe-49d3-b490-3c46cf8e37f1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c7a14033-b9a3-4231-8824-61308ee49db0"}}}}, {"uuid": "86845da4-bb7d-4900-9c00-c6be83efd8ca", "name": "a6904d60-3eda-4ac0-9945-67a01bc5e6d7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7997673490012955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.772957044307952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f8da8d9c-2705-4d59-9e4a-99d23673be05", "name": "b389c1ff-fe5b-4cb8-8253-5b50ddf92ea7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "86845da4-bb7d-4900-9c00-c6be83efd8ca"}}}]}, {"uuid": "b861f8df-f309-4edb-a49e-5abbc43f7496", "name": "load_p1rlv174_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1186295-59ff-48a8-b31d-0f7cd40df1ab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f8da8d9c-2705-4d59-9e4a-99d23673be05"}}}}, {"uuid": "6cada501-95eb-4758-ae39-fe53048531d5", "name": "27711f95-8460-40c6-9724-4f27c75fc0eb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7997673490012955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.772957044307952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7d080bb8-d0ae-4e18-a50e-af67f4a22adb", "name": "38120dbf-2229-4a03-a721-2a227cae7ab8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6cada501-95eb-4758-ae39-fe53048531d5"}}}]}, {"uuid": "5ef0ca22-9b94-4e1c-87b4-ce7fb335b3f8", "name": "load_p1rlv174_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1186295-59ff-48a8-b31d-0f7cd40df1ab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7d080bb8-d0ae-4e18-a50e-af67f4a22adb"}}}}, {"uuid": "32d09fa6-77c4-4c1b-bb61-807cfc09ff43", "name": "c480aefe-44ba-44d6-9062-01b0ef9fd938_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2562100051220524, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.06533962175647968, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e648a41d-31dd-415d-a78b-6f023dfdd28d", "name": "a2b00fbb-9868-459e-91e2-464d724fbbb0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "32d09fa6-77c4-4c1b-bb61-807cfc09ff43"}}}]}, {"uuid": "13593603-abcb-4843-9994-1637c6b41373", "name": "load_p1rlv175_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905e9287-bdb6-44e0-b0af-f59ab4ad4d8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e648a41d-31dd-415d-a78b-6f023dfdd28d"}}}}, {"uuid": "93daaec5-a80d-4c09-a45c-c9e4efe1553c", "name": "4d0e3ca5-98a1-478f-99f3-4c2abe4fecec_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2562100051220524, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.06533962175647968, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "912c8def-e8ae-4a1e-9ad7-0e603c08a529", "name": "4f5b5bcc-a092-48a9-8a4b-19eb8dbf520b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "93daaec5-a80d-4c09-a45c-c9e4efe1553c"}}}]}, {"uuid": "a64c2d9e-7189-4d59-a635-5f3fea3d070e", "name": "load_p1rlv175_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905e9287-bdb6-44e0-b0af-f59ab4ad4d8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "912c8def-e8ae-4a1e-9ad7-0e603c08a529"}}}}, {"uuid": "698bdf1b-1257-4c31-85f8-bacacde1eb47", "name": "babffe7a-fa6f-40a4-a3d7-450c5fbb1531_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6697995975485909, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.41657408993223344, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "407f8084-cfa0-4adf-afe9-7ad0952ad9a8", "name": "180a6a17-b6a5-4caa-a113-9d8208147f1c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "698bdf1b-1257-4c31-85f8-bacacde1eb47"}}}]}, {"uuid": "9d01e606-f835-479b-b804-4f81eef27ac3", "name": "load_p1rlv176_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "931c8cee-89fe-447d-8788-af1e5f9f8775"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "407f8084-cfa0-4adf-afe9-7ad0952ad9a8"}}}}, {"uuid": "99e5d20b-27ce-4d39-b06a-3c44e17dcda4", "name": "e30615b3-a943-46c8-b4e7-5117468922d2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6697995975485909, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.41657408993223344, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e2b94225-1356-4853-bfa6-176c0a433f9b", "name": "a37c0ac8-c612-4374-9882-9cc962aea7b7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "99e5d20b-27ce-4d39-b06a-3c44e17dcda4"}}}]}, {"uuid": "036940e5-1dde-482f-8a28-985360b13eb8", "name": "load_p1rlv176_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "931c8cee-89fe-447d-8788-af1e5f9f8775"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e2b94225-1356-4853-bfa6-176c0a433f9b"}}}}, {"uuid": "8e2d83b6-5e0f-4403-98cc-978ff787b4ca", "name": "42c249c8-a282-4f34-9fa9-663f5b585402_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4063851199490187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16385595528128288, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "811492a9-f6d4-4b8c-80c0-f863291bfcf7", "name": "e9a6c2c9-1727-417b-9248-d78e56d70a45", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8e2d83b6-5e0f-4403-98cc-978ff787b4ca"}}}]}, {"uuid": "29c19a1f-f23f-4648-97ec-b4c8b61f383f", "name": "load_p1rlv177_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "090d6084-5cc6-473d-99c0-a6309571d633"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "811492a9-f6d4-4b8c-80c0-f863291bfcf7"}}}}, {"uuid": "df803f20-308e-4fe6-844b-d129655543e6", "name": "13f10b9b-e510-446b-a882-74a62ae51dc9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4063851199490187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16385595528128288, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c1b844f0-b3b1-4af5-9201-f97f01504132", "name": "6662538b-8582-480c-b4b6-1ccd18cd440c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "df803f20-308e-4fe6-844b-d129655543e6"}}}]}, {"uuid": "d329efae-e466-4e6b-8fb8-24065f82fa03", "name": "load_p1rlv177_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "090d6084-5cc6-473d-99c0-a6309571d633"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c1b844f0-b3b1-4af5-9201-f97f01504132"}}}}, {"uuid": "29520ab8-c7dd-456f-b4db-2b585ff86051", "name": "9b00560f-85e3-4b99-9b63-bb2a4d907d18_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3919966449037446, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.25526897783955566, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eae97a79-5117-4b6a-9c56-897666501298", "name": "e875f6e1-849f-4df7-bbbb-0b36d4833763", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "29520ab8-c7dd-456f-b4db-2b585ff86051"}}}]}, {"uuid": "44644e90-47ad-4157-a7f5-2dd87e9b3172", "name": "load_p1rlv178_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9debf70-62f4-4870-ad8b-bffc4bc4ad3f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eae97a79-5117-4b6a-9c56-897666501298"}}}}, {"uuid": "0a3b3667-f263-4612-968a-c393477614a0", "name": "8428cf0f-b9e1-4726-a653-40ca39b5e34e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3919966449037446, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.25526897783955566, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0c3ae6b3-dc8d-4283-af06-4e0a124a1079", "name": "d670777d-88ca-4db2-925a-b09d361259bd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0a3b3667-f263-4612-968a-c393477614a0"}}}]}, {"uuid": "d628e1e1-2c23-427b-86a1-8a5297639e27", "name": "load_p1rlv178_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9debf70-62f4-4870-ad8b-bffc4bc4ad3f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0c3ae6b3-dc8d-4283-af06-4e0a124a1079"}}}}, {"uuid": "ea998f67-c04a-4494-98c4-064f1a9f2336", "name": "fa1d8715-c8b9-4f92-9f0d-5f38fd60569d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2601927423507288, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13915962527089715, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "428a7349-08ef-465b-8e74-58ac9d3fe537", "name": "75b7c4a3-cf9d-4665-8a74-5895e7bd2fb6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ea998f67-c04a-4494-98c4-064f1a9f2336"}}}]}, {"uuid": "7a97bfc2-9f49-403d-b794-3f116aba6c9a", "name": "load_p1rlv179_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb03260b-d7d7-4779-ab2c-37c9a1e34d66"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "428a7349-08ef-465b-8e74-58ac9d3fe537"}}}}, {"uuid": "4ad41fa7-5d89-41fa-b3e1-a38addab38d1", "name": "0d7f7e8e-b66a-4544-9ac6-0f8fae22229d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2601927423507288, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13915962527089715, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "58befe5b-f61e-4628-a5d3-a10a18294c9b", "name": "73013f72-7f5e-476f-8c35-1d744b0417ef", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4ad41fa7-5d89-41fa-b3e1-a38addab38d1"}}}]}, {"uuid": "651090f6-dde3-4268-b0f7-9b8f180e98f5", "name": "load_p1rlv179_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb03260b-d7d7-4779-ab2c-37c9a1e34d66"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "58befe5b-f61e-4628-a5d3-a10a18294c9b"}}}}, {"uuid": "ed163f46-f389-484a-94fc-a9b331c41498", "name": "a216477c-85cb-41c9-82fb-76a01c8fefea_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2659851154673674, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7880475847724098, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "842b74ac-4c55-4a3a-ab3f-7c4334c352ef", "name": "601af922-d980-495a-8064-27c3cdb0b3bd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ed163f46-f389-484a-94fc-a9b331c41498"}}}]}, {"uuid": "45f3055c-726c-485c-bdd8-1117acdc412a", "name": "load_p1rlv285_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d3a86df-2ac5-4959-b857-562795ce84ba"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "842b74ac-4c55-4a3a-ab3f-7c4334c352ef"}}}}, {"uuid": "c8ac35f5-ff97-4160-9768-d475b43c0558", "name": "b3738bf2-a2c6-46f6-8e66-384b2579bf42_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2659851154673674, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7880475847724098, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a258932-2782-467b-b763-1a702c820449", "name": "a51f40ca-ad49-4ccd-b8ac-c34e8ab16026", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c8ac35f5-ff97-4160-9768-d475b43c0558"}}}]}, {"uuid": "6479420b-32b6-41c7-a90d-68d7d778a703", "name": "load_p1rlv285_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d3a86df-2ac5-4959-b857-562795ce84ba"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0a258932-2782-467b-b763-1a702c820449"}}}}, {"uuid": "1c177bae-3836-497a-9053-d4ead03fbd3c", "name": "e3d417f2-bf21-4f7c-8f2f-5987506a39da_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7aa7dc8d-fb03-4602-a9c7-2c8a3f57e11e", "name": "fe88390d-2742-4c94-9aac-b19ed839235a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1c177bae-3836-497a-9053-d4ead03fbd3c"}}}]}, {"uuid": "4556cea0-a96e-4e33-89b2-36d259fbf452", "name": "load_p1rlv337_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57b88281-b728-4779-82b1-4cc9eb4b41b1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7aa7dc8d-fb03-4602-a9c7-2c8a3f57e11e"}}}}, {"uuid": "f1501d64-73bc-43d1-b883-0c114a180b3f", "name": "b1dd7efd-f593-4adc-8da9-7256bd29e94f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "472244fd-1054-4fbf-a42e-caac2dc2776d", "name": "41ced716-013c-4d5c-a7ed-ff05a893b220", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f1501d64-73bc-43d1-b883-0c114a180b3f"}}}]}, {"uuid": "9ea99031-1a73-4860-8941-03176411c5bf", "name": "load_p1rlv337_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57b88281-b728-4779-82b1-4cc9eb4b41b1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "472244fd-1054-4fbf-a42e-caac2dc2776d"}}}}, {"uuid": "d204acfa-ed37-4a6b-95eb-8de35bfabbc1", "name": "515ac681-bc87-4785-98b5-8f8a94c86b73_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2045141672666357, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3046267940472902, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7289962d-1ada-451f-b2c9-e221764be8f2", "name": "21c661fe-a346-4b28-aa4e-23df3068ca6c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d204acfa-ed37-4a6b-95eb-8de35bfabbc1"}}}]}, {"uuid": "6cbf86aa-64e8-43d6-a2b2-92c2c3acfb3f", "name": "load_p1rlv338_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6b2aba6-a289-4a50-a131-2064047d1341"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7289962d-1ada-451f-b2c9-e221764be8f2"}}}}, {"uuid": "42fbd9cf-1d1c-4abc-85bd-116b6ddf9bfa", "name": "14038502-db61-4a46-b69e-1c39f41d22a3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2045141672666357, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3046267940472902, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1ee17721-78a2-48e2-b84d-63ff7d2774e2", "name": "854c52d5-f691-4c09-b7aa-2defe0872bad", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "42fbd9cf-1d1c-4abc-85bd-116b6ddf9bfa"}}}]}, {"uuid": "c5486f4c-d67c-491a-a3b9-721e60f5bfe3", "name": "load_p1rlv338_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6b2aba6-a289-4a50-a131-2064047d1341"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1ee17721-78a2-48e2-b84d-63ff7d2774e2"}}}}, {"uuid": "6439cd2a-e885-4ff0-886a-36d603472278", "name": "6809aa00-7d60-4f12-bccd-5637e38d38b4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.749950841708346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2019248045205122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "05626810-c934-47c1-9b5e-0be633089952", "name": "9e0a0824-5fa4-4caa-a072-29dd33106920", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6439cd2a-e885-4ff0-886a-36d603472278"}}}]}, {"uuid": "3923f8d0-d62f-4abe-a647-2a3892b503e7", "name": "load_p1rlv340_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb4797d6-b46e-4058-8985-d9f4b660f0a7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "05626810-c934-47c1-9b5e-0be633089952"}}}}, {"uuid": "6c6c9a34-29b0-4314-9fe4-d2c4c3852ee8", "name": "96a9059b-9ada-4807-a11d-56012857b21e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.749950841708346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2019248045205122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6e25347e-dd30-4db8-99fb-a71a4a549692", "name": "ab84c3c8-001a-4eb0-8134-2b8035150c17", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c6c9a34-29b0-4314-9fe4-d2c4c3852ee8"}}}]}, {"uuid": "eb14f439-9aa1-4079-96fe-45e6e5847e93", "name": "load_p1rlv340_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb4797d6-b46e-4058-8985-d9f4b660f0a7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6e25347e-dd30-4db8-99fb-a71a4a549692"}}}}, {"uuid": "ab205c2d-87ef-4ce5-90dc-e70ae13d27f4", "name": "2005a09f-d78d-4c2c-8b43-2a9aba13acc5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7771517670040275, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8838563298920215, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e6a4afe8-741d-460d-9bcc-f3f77a31cc45", "name": "09c46746-251c-4784-8f41-c60a076be7f3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ab205c2d-87ef-4ce5-90dc-e70ae13d27f4"}}}]}, {"uuid": "561c4565-dc97-4f33-8ad7-42971c29c365", "name": "load_p1rlv341_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54f0ea2c-3849-4ff0-ad8c-e3f65515d178"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e6a4afe8-741d-460d-9bcc-f3f77a31cc45"}}}}, {"uuid": "fbebc68b-d886-4b60-bf1b-7197de9935e5", "name": "d6adca28-a492-4e3b-88dd-c246096a3336_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7771517670040275, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8838563298920215, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "191609e9-fb6c-46b6-95dd-29c9168574f4", "name": "156033c8-3e75-405d-af6e-0eb9dc3de4fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fbebc68b-d886-4b60-bf1b-7197de9935e5"}}}]}, {"uuid": "afcd055b-9509-4910-b384-8233cc9e4e6b", "name": "load_p1rlv341_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54f0ea2c-3849-4ff0-ad8c-e3f65515d178"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "191609e9-fb6c-46b6-95dd-29c9168574f4"}}}}, {"uuid": "f63cca78-c62d-445c-8a2e-215e0eab54d9", "name": "b7983a4b-95a0-45fe-b036-0f5c851a90fa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.4540014644243024, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4055170204295049, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82e02e2e-8676-4814-862e-8c81992484b3", "name": "914f473c-173c-49fd-8ea2-c63522e0a60e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f63cca78-c62d-445c-8a2e-215e0eab54d9"}}}]}, {"uuid": "a78c25f5-e873-4dd8-b731-2c3ff4901b82", "name": "load_p1rlv342_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13754fdb-4039-49fb-b584-8437191dfb2b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "82e02e2e-8676-4814-862e-8c81992484b3"}}}}, {"uuid": "3acb654a-aa3c-4022-915f-e73e57b302cd", "name": "241003e9-2fef-4a7f-9350-0e620c9a620c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.4540014644243024, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4055170204295049, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3b3af3e2-a813-4fdc-9902-68f5e308c8d5", "name": "9f040f50-6d2d-4f18-bc6f-2ab763c4f055", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3acb654a-aa3c-4022-915f-e73e57b302cd"}}}]}, {"uuid": "29b09a02-af7d-4f10-a1a5-5b3bb8ac37a8", "name": "load_p1rlv342_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13754fdb-4039-49fb-b584-8437191dfb2b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3b3af3e2-a813-4fdc-9902-68f5e308c8d5"}}}}, {"uuid": "46d2407f-a957-4126-a965-30b5fbbce9d9", "name": "48f60e72-1afb-466c-9907-47aa705e05f0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.13715702476687, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3795210711832634, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "780f8a0e-2872-4cd4-9a86-380a9be5d8a3", "name": "45b5032e-3500-4368-8510-e49470dc54fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "46d2407f-a957-4126-a965-30b5fbbce9d9"}}}]}, {"uuid": "7ca6a310-ece1-4515-b89c-91799dfde079", "name": "load_p1rlv343_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0197ef22-9f8f-48a9-84de-663a7ce22773"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "780f8a0e-2872-4cd4-9a86-380a9be5d8a3"}}}}, {"uuid": "31aaa454-e1df-4166-aa08-efef0b899f81", "name": "3e9d777a-3af9-40a3-b89f-aaa24aa1797e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.13715702476687, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3795210711832634, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cbe8525b-a364-4c00-bada-3cb6d22575fa", "name": "85dab30e-30a4-423c-b797-cd08b694cbdd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "31aaa454-e1df-4166-aa08-efef0b899f81"}}}]}, {"uuid": "1404590a-7410-49e3-a904-b7e2f385f6a7", "name": "load_p1rlv343_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0197ef22-9f8f-48a9-84de-663a7ce22773"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cbe8525b-a364-4c00-bada-3cb6d22575fa"}}}}, {"uuid": "004d9144-06c7-40fa-a842-d07cf3457dac", "name": "98219f76-b003-414b-a065-9d41a2cd7b67_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.2930994643856595, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9073205938076818, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a757014b-52d3-40d4-849a-0de412ddaca2", "name": "ffe8f721-ff1c-41e6-adeb-b778f310e837", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "004d9144-06c7-40fa-a842-d07cf3457dac"}}}]}, {"uuid": "f8c96c76-4500-4902-be1e-8995417b8744", "name": "load_p1rlv377_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e1ea241-5329-4db5-996a-df09a9c25687"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a757014b-52d3-40d4-849a-0de412ddaca2"}}}}, {"uuid": "0dcf4eab-54e8-4541-8890-27e214ff59b7", "name": "a5c27446-e8c1-4d61-bfbd-9c778dabe13c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.2930994643856595, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9073205938076818, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "427eb9c6-1136-418d-abde-61d3a2b4041d", "name": "5432649f-73cd-4435-a788-f7d1b72d0967", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0dcf4eab-54e8-4541-8890-27e214ff59b7"}}}]}, {"uuid": "5ad57ec9-af8b-4b00-a356-ecf78415ae20", "name": "load_p1rlv377_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e1ea241-5329-4db5-996a-df09a9c25687"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "427eb9c6-1136-418d-abde-61d3a2b4041d"}}}}, {"uuid": "94c37143-9b5c-474e-99b2-b002ffbfccb4", "name": "3a44a044-db43-48e8-a935-f5e04bd91034_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.651809392632849, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.766759151751063, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "97f2d645-e451-42da-aece-d78a6970ecfc", "name": "a92532cc-0b0b-49f2-ae7c-ea34320889c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "94c37143-9b5c-474e-99b2-b002ffbfccb4"}}}]}, {"uuid": "d80a4f02-d2e1-4f5a-80e8-45a4378ac616", "name": "load_p1rlv378_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3ff63a0-bf3f-43b0-807c-935467b4fe46"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "97f2d645-e451-42da-aece-d78a6970ecfc"}}}}, {"uuid": "0e323603-a17e-407b-83af-62febe03a71c", "name": "ecaa4e08-c740-4566-8601-9a1491659c6e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.651809392632849, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.766759151751063, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "60f67866-5481-4e96-8dd8-0240b485e74e", "name": "76c22656-994c-4b14-9c13-7b9f159d03dc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0e323603-a17e-407b-83af-62febe03a71c"}}}]}, {"uuid": "8d2908f9-6481-4036-9550-bc9b126c0e7a", "name": "load_p1rlv378_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3ff63a0-bf3f-43b0-807c-935467b4fe46"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "60f67866-5481-4e96-8dd8-0240b485e74e"}}}}, {"uuid": "290ee85f-789b-4ced-8dea-094061874c37", "name": "de0a417d-6eae-4df1-9d8e-97a3d259a85c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.096838644473719, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3876192860701033, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6e4cac71-6f88-414e-9062-1212fb7c57de", "name": "d818b75f-425c-4d11-992e-fbae2b838669", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "290ee85f-789b-4ced-8dea-094061874c37"}}}]}, {"uuid": "73f6f7ba-a150-4170-96bf-a852b546e239", "name": "load_p1rlv379_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50225dcf-40bc-44b5-9dec-072ac5b2334e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6e4cac71-6f88-414e-9062-1212fb7c57de"}}}}, {"uuid": "117a6938-112f-45c1-8ae5-c713f9d0a91b", "name": "d1460c02-979f-46df-9f4e-92cd244a3564_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.096838644473719, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3876192860701033, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9f33b4de-345c-4f35-8e17-a9a339cf2869", "name": "022bd3c9-10ad-44f1-b125-18dea4f660f5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "117a6938-112f-45c1-8ae5-c713f9d0a91b"}}}]}, {"uuid": "34220f1f-be21-4cc4-8bb4-4b7eade70fcb", "name": "load_p1rlv379_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50225dcf-40bc-44b5-9dec-072ac5b2334e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9f33b4de-345c-4f35-8e17-a9a339cf2869"}}}}, {"uuid": "b0b45149-b134-4171-b53b-6dd758d0a7a4", "name": "0010f4b1-dc0e-4d20-b884-f9e6ec67d62e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5996895391512607, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5332968923160806, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "24a9217d-fe72-4420-8696-febd57d3910f", "name": "834f12fe-e7fb-4be2-924c-e758065cedb2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b0b45149-b134-4171-b53b-6dd758d0a7a4"}}}]}, {"uuid": "f534baff-d593-496b-b97d-4d6125708942", "name": "load_p1rlv380_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ee07ef9-b7b0-4457-be1c-78e754dbcfc7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "24a9217d-fe72-4420-8696-febd57d3910f"}}}}, {"uuid": "13a657a3-c0e6-4664-bbdf-f01b5a50223b", "name": "cd7ba6a9-1d52-499b-9fde-a6e4f4375cb7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5996895391512607, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5332968923160806, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fb8d2ec8-db5f-492e-8273-caea9dfba693", "name": "4c6be107-899d-468e-b909-872fd2bdd8a9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "13a657a3-c0e6-4664-bbdf-f01b5a50223b"}}}]}, {"uuid": "75ccf78c-c765-41a6-bb56-37de514dfd86", "name": "load_p1rlv380_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ee07ef9-b7b0-4457-be1c-78e754dbcfc7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fb8d2ec8-db5f-492e-8273-caea9dfba693"}}}}, {"uuid": "9edb37d5-caa0-4b00-9a26-a1aef7b642d2", "name": "2f2f95a1-ff09-4219-9373-12da064989c4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2825930802168721, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5903675615779559, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9f696408-f8d5-435c-b48a-a1b120d685f5", "name": "f3de3b82-5836-4416-aeac-2bd18e3337a2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9edb37d5-caa0-4b00-9a26-a1aef7b642d2"}}}]}, {"uuid": "1201db9d-fab3-415c-8e76-196f246cee65", "name": "load_p1rlv412_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b33ed36-116b-4741-9374-6927bd537427"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9f696408-f8d5-435c-b48a-a1b120d685f5"}}}}, {"uuid": "73ab955f-6770-4bd4-8b30-d11d86f9c7e3", "name": "f5f99842-6cc1-45f2-9739-1134e07d34ec_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2825930802168721, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5903675615779559, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fd4a14f5-a2b4-4f81-821c-6ddbe1b5a91a", "name": "ec891b7a-d6d3-4735-8205-10cb67fdb0b6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "73ab955f-6770-4bd4-8b30-d11d86f9c7e3"}}}]}, {"uuid": "1b537d77-e45c-4ae0-8dea-bc86cdd481b6", "name": "load_p1rlv412_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b33ed36-116b-4741-9374-6927bd537427"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fd4a14f5-a2b4-4f81-821c-6ddbe1b5a91a"}}}}, {"uuid": "84949f0b-d44d-4a0a-9a39-3365a68a2314", "name": "b66335e1-8e77-471c-a647-d252b422f28a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5218330234822437, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6111559757217505, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "956c3863-e83f-4114-89f4-119b9934a4bc", "name": "f20afc4a-dda8-4342-a86a-736bfec026d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "84949f0b-d44d-4a0a-9a39-3365a68a2314"}}}]}, {"uuid": "257f2e68-1456-4e2f-8fe7-fe6c17012ce3", "name": "load_p1rlv413_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8408ac87-a086-46bc-9d88-cca79e17dd62"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "956c3863-e83f-4114-89f4-119b9934a4bc"}}}}, {"uuid": "b2175bbc-4c32-40bb-9689-315b3bcc6d77", "name": "4d03acdd-3b5a-4a2f-9bde-c864876ffc0f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5218330234822437, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6111559757217505, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5607d053-3b06-4109-a565-cfa46dd43ff6", "name": "114afa60-6b70-4d0d-88be-b71871e0249b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b2175bbc-4c32-40bb-9689-315b3bcc6d77"}}}]}, {"uuid": "3cd0305c-20bb-422f-ade5-5c72aa5bf079", "name": "load_p1rlv413_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8408ac87-a086-46bc-9d88-cca79e17dd62"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5607d053-3b06-4109-a565-cfa46dd43ff6"}}}}, {"uuid": "25658ac8-9f93-4d5c-92bd-34dd271c0f9e", "name": "668f02ae-de18-4809-9dd7-a058c84d5985_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.307247144150686, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17783357819798717, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a7fe75cd-0f4b-4b3c-ae8b-71f0919b3f14", "name": "fb1e58e1-f7b4-4623-8ba6-1d4e7529a98e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "25658ac8-9f93-4d5c-92bd-34dd271c0f9e"}}}]}, {"uuid": "35b4e3bb-abfb-4915-bf67-85f1523b4a79", "name": "load_p1rlv414_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec2c1edd-78b1-4436-85cc-2fbc7d880b87"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a7fe75cd-0f4b-4b3c-ae8b-71f0919b3f14"}}}}, {"uuid": "b0150c1f-3a29-4ff7-826e-65ce32bf3402", "name": "3eb4c88f-abac-453f-9d93-39ef129a1d8f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.307247144150686, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17783357819798717, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ff753503-a4c9-4e5b-a4dd-6695e34a72cf", "name": "30305ae5-0ba2-41ba-8318-c583c284b3b7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b0150c1f-3a29-4ff7-826e-65ce32bf3402"}}}]}, {"uuid": "4bdf7a06-175a-4680-9f3f-f675b8c9e04b", "name": "load_p1rlv414_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec2c1edd-78b1-4436-85cc-2fbc7d880b87"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ff753503-a4c9-4e5b-a4dd-6695e34a72cf"}}}}, {"uuid": "5a4ad912-137b-4edb-80e4-bdf9777227e0", "name": "b5e7052a-bbd0-4b2c-ab85-b69824d5cd68_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5478654763148745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5646840796232575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2d39b745-c630-47ab-9da9-88d2b940963e", "name": "100b605b-2a00-4b97-9ec6-48a6ccc8f450", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5a4ad912-137b-4edb-80e4-bdf9777227e0"}}}]}, {"uuid": "a9fd2337-e212-4577-b3e0-d54b489d242f", "name": "load_p1rlv415_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b54aae8-5a94-4e04-882f-748e1c5f1390"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2d39b745-c630-47ab-9da9-88d2b940963e"}}}}, {"uuid": "9752f792-cdad-4a22-8069-f260252ead54", "name": "79c4a47c-32a3-4c67-9a2b-803120fdff31_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5478654763148745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5646840796232575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5bb18331-14c7-4223-b4e8-25be9b609caa", "name": "46a57404-cee0-492b-84c7-8022e3de81fc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9752f792-cdad-4a22-8069-f260252ead54"}}}]}, {"uuid": "544ef15a-50b6-4c3e-bcfb-05594c086a25", "name": "load_p1rlv415_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b54aae8-5a94-4e04-882f-748e1c5f1390"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5bb18331-14c7-4223-b4e8-25be9b609caa"}}}}, {"uuid": "236f88fc-0b20-4017-9d1f-675e72532aa8", "name": "5d27f300-a078-47fe-8758-e12c363092a5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2437699409140923, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5571842941855458, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fe160672-65f9-422a-9671-4bdc27a622cb", "name": "f786ba5b-b576-41c9-b08d-f961568173e3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "236f88fc-0b20-4017-9d1f-675e72532aa8"}}}]}, {"uuid": "4ff614f9-c0c4-40d4-bfa4-88e78ed45956", "name": "load_p1rlv416_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99abc7dc-8e15-420f-9bc9-0e6229d4dab3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fe160672-65f9-422a-9671-4bdc27a622cb"}}}}, {"uuid": "8aed49d1-541b-4b5c-9f2e-3c5cff27502e", "name": "1e7379ad-fa51-40c3-90eb-d3c5e01261aa_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2437699409140923, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5571842941855458, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1d2b8e34-0dc2-4c63-81ad-6d79487b2e54", "name": "40629f65-fa44-4e45-a92a-3643edc7dc74", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8aed49d1-541b-4b5c-9f2e-3c5cff27502e"}}}]}, {"uuid": "82c78be7-41d1-4915-8907-9969c6287ce0", "name": "load_p1rlv416_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99abc7dc-8e15-420f-9bc9-0e6229d4dab3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1d2b8e34-0dc2-4c63-81ad-6d79487b2e54"}}}}, {"uuid": "55122e3e-f38d-4d1b-86da-c7401f27692e", "name": "fcbad943-9a9c-47ee-a121-c4676330ce18_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1698158732703443, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8490689598373361, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ef1bdc26-4c6e-4e24-8d2f-6bb4f0406a79", "name": "2f060849-2e72-4eea-b384-048580d8e5fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "55122e3e-f38d-4d1b-86da-c7401f27692e"}}}]}, {"uuid": "cd8c15e0-e322-449b-bce6-7a643e578731", "name": "load_p1rlv417_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49dbdd44-a36a-46b5-aef8-558ef7693315"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ef1bdc26-4c6e-4e24-8d2f-6bb4f0406a79"}}}}, {"uuid": "74a63396-c2b6-4f4b-af3f-43efe8e564a9", "name": "c7df32c2-cdf3-45b5-90fc-57e75e7e30b1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1698158732703443, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8490689598373361, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "49b098d1-e734-47b1-a9da-6c4a48a0520a", "name": "30e3bf61-f498-4702-81ef-3a75714458e8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "74a63396-c2b6-4f4b-af3f-43efe8e564a9"}}}]}, {"uuid": "f8e88484-6c6e-45e3-a52a-e736bf05bff7", "name": "load_p1rlv417_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49dbdd44-a36a-46b5-aef8-558ef7693315"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "49b098d1-e734-47b1-a9da-6c4a48a0520a"}}}}, {"uuid": "ab938fa9-a68b-400e-a8e7-d64902836b00", "name": "32268d5a-2da6-4aa3-b876-ced5699e0813_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "58a9e0b3-d78c-4ac9-9604-2a109b6f58a4", "name": "b375611a-bb86-4e95-801c-434f495d8c60", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ab938fa9-a68b-400e-a8e7-d64902836b00"}}}]}, {"uuid": "e39d1d14-3bf8-4464-ae5e-e71464d9438f", "name": "load_p1rlv418_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b54aae8-5a94-4e04-882f-748e1c5f1390"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "58a9e0b3-d78c-4ac9-9604-2a109b6f58a4"}}}}, {"uuid": "1f37b3c6-3ecf-43ad-9e38-3a3dc3a0cc26", "name": "6f014ce4-d03c-4b4e-945a-3d1eba73bdec_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "63163c6c-7cba-4439-850c-9084634f2124", "name": "f4ba3843-c683-4ff0-92b9-ef860b481e32", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1f37b3c6-3ecf-43ad-9e38-3a3dc3a0cc26"}}}]}, {"uuid": "f244f5bf-9001-4806-a729-a2167668ce93", "name": "load_p1rlv418_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b54aae8-5a94-4e04-882f-748e1c5f1390"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "63163c6c-7cba-4439-850c-9084634f2124"}}}}, {"uuid": "55a6f0de-1376-4b1c-b506-a6f1d294f948", "name": "0165d7b3-8b43-47c0-8136-0fbfff30a059_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7500687162104853, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7707974088873139, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b043d947-32fc-4198-b244-45fc8c302d0a", "name": "bf1977d4-2132-4dfc-97c4-179e2d725e4a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "55a6f0de-1376-4b1c-b506-a6f1d294f948"}}}]}, {"uuid": "d8182e93-d5f4-4313-ade2-e469a3bb5d8c", "name": "load_p1rlv419_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7935b9c-b631-432c-a322-9beea73f1fc4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b043d947-32fc-4198-b244-45fc8c302d0a"}}}}, {"uuid": "dd9ae778-2841-4cae-80ae-503efc54ca9c", "name": "6f2adaac-f7b6-408c-9907-ab7bc43f7bee_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7500687162104853, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7707974088873139, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2c97cf19-a37a-4490-bae2-368b37e51bca", "name": "7962d5af-9a27-4c06-9a06-c5c13eb29a5b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dd9ae778-2841-4cae-80ae-503efc54ca9c"}}}]}, {"uuid": "6fba622d-d85c-4cfa-b494-58951b880d4e", "name": "load_p1rlv419_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7935b9c-b631-432c-a322-9beea73f1fc4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2c97cf19-a37a-4490-bae2-368b37e51bca"}}}}, {"uuid": "2a3896a4-969d-48ca-baab-71091982350d", "name": "3cff9dd6-70ac-4346-b7e0-30d7b4c5b2cf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6434260893942235, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2588956175598443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6447e97c-5dd4-4d30-a85b-0bc2e08e72db", "name": "5995a59c-f31e-42b9-b7b1-7f975115716b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2a3896a4-969d-48ca-baab-71091982350d"}}}]}, {"uuid": "0aa79a4c-aea1-4025-9923-8593ea232b24", "name": "load_p1rlv420_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4d7ed8-5ddd-4127-87ab-eb3f48a580c2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6447e97c-5dd4-4d30-a85b-0bc2e08e72db"}}}}, {"uuid": "cdec3867-35e4-4fb8-8021-a976b3d2b085", "name": "9cd4ca9f-c37d-4ab7-9917-3d19039f140a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6434260893942235, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2588956175598443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "25b0c049-def9-4072-b041-5bf6ee171db9", "name": "d0b9cd2b-09f6-49ae-aa4e-88d98a0ebd82", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cdec3867-35e4-4fb8-8021-a976b3d2b085"}}}]}, {"uuid": "94167872-f880-4f9c-af3a-1e15003d571b", "name": "load_p1rlv420_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4d7ed8-5ddd-4127-87ab-eb3f48a580c2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "25b0c049-def9-4072-b041-5bf6ee171db9"}}}}, {"uuid": "3c53efed-5f98-4e1d-9121-1df30d025cc9", "name": "62b17c48-45de-45fd-9566-27fe55bf2649_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6669289783709, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.056901546523703654, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "996a80b3-261b-43a1-91c5-21c792a73994", "name": "8b92c237-c090-4e84-b560-99c2e5c9ae24", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3c53efed-5f98-4e1d-9121-1df30d025cc9"}}}]}, {"uuid": "563cc9c0-de0d-400a-8f79-e346ad461693", "name": "load_p1rlv421_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12dcb168-1bfe-448b-8d9a-f5cb4c61aafe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "996a80b3-261b-43a1-91c5-21c792a73994"}}}}, {"uuid": "7de77097-4a79-4bfe-b65e-29cbf44811c2", "name": "6e0fe43e-b16c-4f7e-9349-d521a6f60151_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6669289783709, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.056901546523703654, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0fde27dd-70e3-42a9-b281-117a5b6ded40", "name": "9d4161dc-d429-4582-96aa-69a6db295ab8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7de77097-4a79-4bfe-b65e-29cbf44811c2"}}}]}, {"uuid": "c797796a-12c9-439b-903d-d720319a9f5d", "name": "load_p1rlv421_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12dcb168-1bfe-448b-8d9a-f5cb4c61aafe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0fde27dd-70e3-42a9-b281-117a5b6ded40"}}}}, {"uuid": "05991d9c-522e-4349-a36c-fd44e2dd07f1", "name": "324242e3-d208-4a59-9931-b871fa753018_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.933146793098512, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9686684100837105, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9cfd504c-4877-491c-912c-fbe81dace76d", "name": "1c7d4e5f-3295-40b5-81f0-0c4074306a7c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "05991d9c-522e-4349-a36c-fd44e2dd07f1"}}}]}, {"uuid": "ff597d6c-e00d-46a3-ba9b-b0e0829959ac", "name": "load_p1rlv422_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa7bb51b-8ba8-4a05-872a-7f5ce084fe88"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9cfd504c-4877-491c-912c-fbe81dace76d"}}}}, {"uuid": "c10cf9cb-91fc-4e09-8683-2c939cc3a0bb", "name": "da66753e-185f-4c0c-a216-68566b61192d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.933146793098512, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9686684100837105, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4d9d9d46-178a-427d-9a33-efb4da3cefdc", "name": "cd2b9061-a50c-466b-be80-2aefbd0c6ce2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c10cf9cb-91fc-4e09-8683-2c939cc3a0bb"}}}]}, {"uuid": "2b22dc58-7860-4849-a2c5-d982f61301e8", "name": "load_p1rlv422_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa7bb51b-8ba8-4a05-872a-7f5ce084fe88"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4d9d9d46-178a-427d-9a33-efb4da3cefdc"}}}}, {"uuid": "33520d61-57c6-4233-8f24-2ca00485cd8f", "name": "b29beaa2-d8b8-47b8-abe4-d78d560ae6a2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0491915565570302, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1506537762556939, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "94a80965-d56a-49e4-99d1-7130b1ec198b", "name": "74a55b1d-5afa-4d60-9810-cb3ec599c176", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "33520d61-57c6-4233-8f24-2ca00485cd8f"}}}]}, {"uuid": "bfa11df5-c4a4-4ab5-9b53-898280a44040", "name": "load_p1rlv423_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c1e9680-f7de-497c-953a-54f4db2899e2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "94a80965-d56a-49e4-99d1-7130b1ec198b"}}}}, {"uuid": "a118a7a2-88e6-42c5-89d9-6b41a6ab039e", "name": "e3e4422d-36a0-4d91-a6e5-924efb122083_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0491915565570302, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1506537762556939, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3182748a-a6d3-48e9-941a-e62456a53155", "name": "98a6588c-0e54-4694-a589-f9f6c573c398", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a118a7a2-88e6-42c5-89d9-6b41a6ab039e"}}}]}, {"uuid": "ccf1c0f6-b41e-4007-9928-38c149b8bd6e", "name": "load_p1rlv423_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c1e9680-f7de-497c-953a-54f4db2899e2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3182748a-a6d3-48e9-941a-e62456a53155"}}}}, {"uuid": "4b837012-2e6a-4090-970b-750f34a1077a", "name": "510ecdc7-345f-4f8a-ac44-5323ed39c728_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.048430097374791, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0714377119995753, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bca6a3d7-d6ea-448c-870e-e5499cb6e352", "name": "cc5170e1-d5c0-4e1e-bcdf-4f86e9f197ee", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4b837012-2e6a-4090-970b-750f34a1077a"}}}]}, {"uuid": "00ca86be-72b4-4af6-9b27-7d5bd262f58b", "name": "load_p1rlv424_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1a91c8c-aabd-4fad-8306-908f186a5744"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bca6a3d7-d6ea-448c-870e-e5499cb6e352"}}}}, {"uuid": "5ee2aac4-fd28-492c-9fbf-e14dcfeb1f56", "name": "565efea5-5d16-4069-b9fe-e78a3eb0aedd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.048430097374791, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0714377119995753, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8491090d-1a03-4ae5-bc2b-f1030da5f1f0", "name": "eb6eef64-a023-4f01-8fcf-4239d57adb32", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5ee2aac4-fd28-492c-9fbf-e14dcfeb1f56"}}}]}, {"uuid": "3d6b51d0-c70c-4997-b523-7e7d83ed4353", "name": "load_p1rlv424_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1a91c8c-aabd-4fad-8306-908f186a5744"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8491090d-1a03-4ae5-bc2b-f1030da5f1f0"}}}}, {"uuid": "4c4d408d-bb5c-4094-8251-2bc68ca55034", "name": "310a4edf-3ccc-42ce-a1a4-b52e410a0b85_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8920557288657344, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21990443750848332, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "65ef3c3d-4484-4297-aba5-6eab04605e0f", "name": "24317571-168d-4b75-88d9-4f43c51bc8cf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4c4d408d-bb5c-4094-8251-2bc68ca55034"}}}]}, {"uuid": "d306d9a0-8ad6-4e4a-9f58-981adc0e3883", "name": "load_p1rlv439_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f771660-4dad-43df-b38b-7da5f6180a25"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "65ef3c3d-4484-4297-aba5-6eab04605e0f"}}}}, {"uuid": "3ce337f3-148a-4e7d-9b88-c7750feec37b", "name": "c3a89a09-dc57-4336-ab2b-cad574ec511b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8920557288657344, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21990443750848332, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7c5b24e7-f210-4a14-978c-d3f2bb483082", "name": "2587354e-c5c0-4ba2-ac28-50bec7d9a608", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3ce337f3-148a-4e7d-9b88-c7750feec37b"}}}]}, {"uuid": "256a6866-9c80-4f16-82fd-de7eaae686d7", "name": "load_p1rlv439_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f771660-4dad-43df-b38b-7da5f6180a25"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7c5b24e7-f210-4a14-978c-d3f2bb483082"}}}}, {"uuid": "5261793a-bf29-4c04-8a01-f2d88cc6722d", "name": "2df4b933-77e6-4412-9d27-90b3200a8993_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 16.24059147715281, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.317949795825311, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c4b10fa3-3e22-4c45-9915-cdb65b4cd420", "name": "2df4b933-77e6-4412-9d27-90b3200a8993_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 16.24059147715281, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.317949795825311, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bef03be8-2fa9-4053-97dd-093966a78bee", "name": "2df4b933-77e6-4412-9d27-90b3200a8993_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 16.24059147715281, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.317949795825311, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0bce5227-fc0c-42c0-a499-e53e72b093b7", "name": "58ae15dd-8489-4925-9705-4352ad3f5f7c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5261793a-bf29-4c04-8a01-f2d88cc6722d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c4b10fa3-3e22-4c45-9915-cdb65b4cd420"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bef03be8-2fa9-4053-97dd-093966a78bee"}}}]}, {"uuid": "b1e406c4-63ea-4a23-9d16-363dd259c73b", "name": "load_p1rlv440", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a23f97bc-e7ef-4f64-9e64-314f4a4e17d8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0bce5227-fc0c-42c0-a499-e53e72b093b7"}}}}, {"uuid": "9894d818-8308-4bbc-9f1e-d9074e63f268", "name": "4ad605bf-5a6e-4a72-9956-2536b0fc3b8a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4856814769108864, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8267323554826451, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c542f525-2856-42c6-9de3-5a1f4448113a", "name": "c9021d60-4ed5-4971-adc8-a100beff3342", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9894d818-8308-4bbc-9f1e-d9074e63f268"}}}]}, {"uuid": "5634e75d-43ab-46fd-a2f7-8f7fd2130563", "name": "load_p1rlv441_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a778b00-482c-4b81-8213-f17202a105fa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c542f525-2856-42c6-9de3-5a1f4448113a"}}}}, {"uuid": "25db585c-f02f-4651-9b6a-4fde07288939", "name": "9e1ec08a-7e98-41f3-aec3-501011911653_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4856814769108864, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8267323554826451, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "308df291-ae5e-463c-b62e-5f1df7e8c52f", "name": "a53be65f-b7dc-44ce-bc4c-8cf2befe86cf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "25db585c-f02f-4651-9b6a-4fde07288939"}}}]}, {"uuid": "67265199-e9b6-4225-bd80-a5303316a244", "name": "load_p1rlv441_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a778b00-482c-4b81-8213-f17202a105fa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "308df291-ae5e-463c-b62e-5f1df7e8c52f"}}}}, {"uuid": "9487f595-09d1-4a90-beeb-96cd696e5b1d", "name": "6a0a6019-6ae9-4cb3-8832-1f1ae030f058_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.930214175792893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.08514782397789, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "453f8cfc-b505-47b5-a735-bd50a661eff3", "name": "a2903bfb-4002-4629-aa28-100a4ac73fbf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9487f595-09d1-4a90-beeb-96cd696e5b1d"}}}]}, {"uuid": "6d52ad2a-64bf-47cf-8206-746d44da5175", "name": "load_p1rlv442_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cd667a9-c0ef-49ce-b6ee-7e474d9ae761"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "453f8cfc-b505-47b5-a735-bd50a661eff3"}}}}, {"uuid": "216ec404-c4bd-4582-a482-e9adf27caac9", "name": "b58ba976-9653-4229-9372-2c11f1567a42_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.930214175792893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.08514782397789, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2fce8bd0-bd8d-47c6-a08f-db1e08281e9a", "name": "3de521c0-c2e3-4a13-b814-a09c6af31021", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "216ec404-c4bd-4582-a482-e9adf27caac9"}}}]}, {"uuid": "57e4bfe6-8249-482d-9a03-7ad1b74d4c0a", "name": "load_p1rlv442_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cd667a9-c0ef-49ce-b6ee-7e474d9ae761"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2fce8bd0-bd8d-47c6-a08f-db1e08281e9a"}}}}, {"uuid": "9d74f642-1a58-435c-9922-c95f0a9d371a", "name": "ef632798-1b8c-46da-93d8-b0772f08d5f5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7859412473782077, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.762455747973555, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a79978f4-da2d-4611-9e3e-c29a191a7c4c", "name": "0406b84e-e9a4-4851-a993-006de690057e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9d74f642-1a58-435c-9922-c95f0a9d371a"}}}]}, {"uuid": "55cacdf5-2f34-4f91-a63c-67bda85ddefd", "name": "load_p1rlv443_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2100c17-c0e6-47e9-87f8-72016b22dd4b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a79978f4-da2d-4611-9e3e-c29a191a7c4c"}}}}, {"uuid": "b92e692b-da63-4550-a63f-c76c7e192283", "name": "fc7a501e-9c79-454e-be5c-c64f19f2ba0a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7859412473782077, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.762455747973555, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1a7e41f3-f106-40cd-b1c9-468f9c6f612b", "name": "3fce7f30-a9c4-47c8-a6fa-7dcfafdf4e9f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b92e692b-da63-4550-a63f-c76c7e192283"}}}]}, {"uuid": "e74a9ba3-c552-4ba4-ab09-d0ac5a978fcd", "name": "load_p1rlv443_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2100c17-c0e6-47e9-87f8-72016b22dd4b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1a7e41f3-f106-40cd-b1c9-468f9c6f612b"}}}}, {"uuid": "ba02ec92-c842-49fd-a668-18b6792718d9", "name": "315ec56e-8ab3-4602-b49d-bc960908c944_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1461342593009323, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5165512162199262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fc06d0ff-46e7-414c-a1a0-9fec97e1ed9a", "name": "b9047550-16e2-4235-bc0a-cdc6804ea240", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ba02ec92-c842-49fd-a668-18b6792718d9"}}}]}, {"uuid": "97174b9f-f9fe-4498-b530-e8d01c2c0522", "name": "load_p1rlv444_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30f29674-3083-4da2-95e2-a1f11a7eb7f8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fc06d0ff-46e7-414c-a1a0-9fec97e1ed9a"}}}}, {"uuid": "a686f642-643e-46b3-b1c7-f36193346147", "name": "bc70b632-df4e-49f4-a0d2-9586c52f1e8e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1461342593009323, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5165512162199262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "505ad3a5-7414-4fda-b5a4-22e9cc3d8765", "name": "393488ca-8f05-47f5-baaa-e7031131f84e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a686f642-643e-46b3-b1c7-f36193346147"}}}]}, {"uuid": "0a1432fb-6cad-4f4b-901c-b36108aedbff", "name": "load_p1rlv444_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30f29674-3083-4da2-95e2-a1f11a7eb7f8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "505ad3a5-7414-4fda-b5a4-22e9cc3d8765"}}}}, {"uuid": "697c28aa-80d6-4999-95db-098093347a29", "name": "f18426f4-6aa9-4aa9-8422-6d06a64a1243_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3269645363150677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5800133371554559, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a2eef9f-d812-4a82-ba33-8a0826a6fcfd", "name": "f4587ba9-bfbe-4da6-b1be-e6563afc89e6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "697c28aa-80d6-4999-95db-098093347a29"}}}]}, {"uuid": "7cf88d07-693e-4f44-9c68-da32cee2458a", "name": "load_p1rlv445_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d665758-71e1-4478-b39d-671f78f623e5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a2eef9f-d812-4a82-ba33-8a0826a6fcfd"}}}}, {"uuid": "93de3409-9b99-43c0-b071-432c2d9c2e37", "name": "32d226d5-0ef5-4eb9-8b29-fea2daef4505_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3269645363150677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5800133371554559, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0242c41e-10a4-437a-846a-b1ac803df3a3", "name": "212a1fef-e01a-457b-b81f-5e7385b6de57", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "93de3409-9b99-43c0-b071-432c2d9c2e37"}}}]}, {"uuid": "17ce9b5b-47c0-4564-8cd7-2905a8590713", "name": "load_p1rlv445_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d665758-71e1-4478-b39d-671f78f623e5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0242c41e-10a4-437a-846a-b1ac803df3a3"}}}}, {"uuid": "b1ebaca0-d070-46a2-baf4-37aa4cc91c98", "name": "c13b909a-5ec0-4470-982d-8d00eef6dd35_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.810132764673673, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.37076490271254653, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "47e98740-9410-49dc-bed7-d38f767046cf", "name": "626559fd-4634-49fc-8d96-151af2878a5e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b1ebaca0-d070-46a2-baf4-37aa4cc91c98"}}}]}, {"uuid": "9ee773f3-ecf1-4c59-b54e-bb9eedf8e0c5", "name": "load_p1rlv446_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acce3105-f519-491c-921a-df1294795742"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "47e98740-9410-49dc-bed7-d38f767046cf"}}}}, {"uuid": "37f518c3-137c-4023-b8ad-36e6b4dd34a9", "name": "585e9a13-274d-4cc5-bc4d-4885c2b50332_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.810132764673673, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.37076490271254653, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e968e1ca-f469-47e8-bf0f-725ddeedea33", "name": "8e71cb50-7cce-49c4-8217-d40239f37d78", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "37f518c3-137c-4023-b8ad-36e6b4dd34a9"}}}]}, {"uuid": "3bfe5804-c45b-43d3-829e-c49058179c31", "name": "load_p1rlv446_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acce3105-f519-491c-921a-df1294795742"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e968e1ca-f469-47e8-bf0f-725ddeedea33"}}}}, {"uuid": "cbbf026e-f948-4aed-be19-605541ad1420", "name": "cd7abfd6-7f0e-4a14-b7e3-ce91d3553671_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.606460911827677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.1012105340517033, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "80ccb464-d7bc-45ce-88ae-1568eed1f7df", "name": "5b26b15c-9edc-40c4-993a-8e67a69dec14", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cbbf026e-f948-4aed-be19-605541ad1420"}}}]}, {"uuid": "adcf1f3d-8e55-4089-8a27-4424b2d292dd", "name": "load_p1rlv447_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "042873fa-10df-4de0-a040-ac429b8bf7d9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "80ccb464-d7bc-45ce-88ae-1568eed1f7df"}}}}, {"uuid": "17cc2108-3c91-4142-9885-a7ab233506b5", "name": "7a1dda18-7e0c-4e50-aad9-429562d6d099_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.606460911827677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.1012105340517033, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dbe26070-4c19-4de3-8c5d-ee36a45cb679", "name": "d4c7bb47-ea9a-4416-a135-b1e974019adc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "17cc2108-3c91-4142-9885-a7ab233506b5"}}}]}, {"uuid": "3be041c5-000b-4d30-b42f-7219011ace44", "name": "load_p1rlv447_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "042873fa-10df-4de0-a040-ac429b8bf7d9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dbe26070-4c19-4de3-8c5d-ee36a45cb679"}}}}, {"uuid": "0302377c-9560-40df-b94e-7d47958e7e2f", "name": "36e137af-4506-41c5-88d4-13cc37413ad7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.241801892330501, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.45459688794228914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b76e2b4d-44de-488e-a2b0-fe0ab4d9fc6a", "name": "0fc2a879-4524-4454-8d0c-af1cd2f4ddc9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0302377c-9560-40df-b94e-7d47958e7e2f"}}}]}, {"uuid": "eab61bbb-5785-4d80-921a-cc241f8d8ffb", "name": "load_p1rlv448_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bb83d65-630d-4f1d-8e3d-8937a5a05524"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b76e2b4d-44de-488e-a2b0-fe0ab4d9fc6a"}}}}, {"uuid": "04c1ee12-8cdc-4a0f-871d-eb504a594131", "name": "f9a9fd1c-da0f-499b-8ed9-4e1e75ba09bc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.241801892330501, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.45459688794228914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a9d755ea-888b-484b-b184-f574920bbd11", "name": "31f55e2b-c26e-419e-a2d2-82d1ffb69f9a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "04c1ee12-8cdc-4a0f-871d-eb504a594131"}}}]}, {"uuid": "01eeac4e-7618-4bd3-b15c-a531cc23386a", "name": "load_p1rlv448_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bb83d65-630d-4f1d-8e3d-8937a5a05524"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a9d755ea-888b-484b-b184-f574920bbd11"}}}}, {"uuid": "f6f07fed-ee95-42bb-9b2f-99cdbcc98836", "name": "6c3bbabf-0f96-4ad5-baf6-a8243db13b5f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.290770207979584, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.15121699106508624, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a3c85719-80c2-4257-aadc-5358eebfe11b", "name": "fafbfad2-39cd-4a47-8588-f97146a2a530", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f6f07fed-ee95-42bb-9b2f-99cdbcc98836"}}}]}, {"uuid": "ba3cad7c-886c-4aec-bac5-7664880c8a25", "name": "load_p1rlv449_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "753035df-8705-48eb-92b3-c4bef603b66b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a3c85719-80c2-4257-aadc-5358eebfe11b"}}}}, {"uuid": "9fe52978-caa5-4c34-854e-f4eb88ec571f", "name": "c5e484af-10f2-4d14-882c-a3305f0f92d8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.290770207979584, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.15121699106508624, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "16df0960-22c5-4e53-895d-1586ecbecb14", "name": "6abf24ac-9d6c-4c58-a7a0-73fcf29fa5d6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9fe52978-caa5-4c34-854e-f4eb88ec571f"}}}]}, {"uuid": "fd3f66c4-070f-4567-8f8f-046fd7fc7953", "name": "load_p1rlv449_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "753035df-8705-48eb-92b3-c4bef603b66b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "16df0960-22c5-4e53-895d-1586ecbecb14"}}}}, {"uuid": "bddf4021-0bda-4b02-8584-83cb52ea6df6", "name": "573539e9-7e06-4a2e-8d2e-c61eecc3042d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.074192704000552, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.129078804753558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6529e2b5-4cec-4e70-ae8e-0fb735fc49c7", "name": "e9bfea5c-766e-4e0f-98cd-af636b88abd9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bddf4021-0bda-4b02-8584-83cb52ea6df6"}}}]}, {"uuid": "f56e4e94-fe53-4378-9421-65c4497ea5d9", "name": "load_p1rlv452_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb46f1ae-0cdb-45d1-b389-639cdf345f8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6529e2b5-4cec-4e70-ae8e-0fb735fc49c7"}}}}, {"uuid": "8baa3ae2-948d-4504-8e5f-96544b5bff7d", "name": "0704b8cb-b9f0-413b-844a-b8232935edf0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.074192704000552, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.129078804753558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "57d1c980-b6f4-4f7b-9cbe-9be88495d841", "name": "a302670d-46d5-4562-bd79-162909ef155a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8baa3ae2-948d-4504-8e5f-96544b5bff7d"}}}]}, {"uuid": "33892645-c73d-42da-9133-c45f150cfe05", "name": "load_p1rlv452_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb46f1ae-0cdb-45d1-b389-639cdf345f8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "57d1c980-b6f4-4f7b-9cbe-9be88495d841"}}}}, {"uuid": "99f3b56a-cb1e-43d1-bd43-4c73175033c1", "name": "cc4294ad-1de6-403b-b2b5-71056cc2f3fe_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2596055778412756, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4460523908595607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9b0b62d1-9bd0-450b-9454-3dae35c5bb13", "name": "66d2645b-5405-436b-a633-5b7d8b80ad2c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "99f3b56a-cb1e-43d1-bd43-4c73175033c1"}}}]}, {"uuid": "26f59976-54ab-440b-a03f-d9ddaecc9239", "name": "load_p1rlv453_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6a8a3c7-5165-48b7-8233-30d3af045442"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9b0b62d1-9bd0-450b-9454-3dae35c5bb13"}}}}, {"uuid": "7bcd775c-fb87-4ffd-be72-aa4957ceb9fc", "name": "e5e9ddd3-8c92-4393-8c95-8ff5ce52a467_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2596055778412756, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4460523908595607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "795c5ff0-765b-4d2e-84e6-b605b9f21f84", "name": "db356f00-6f24-406a-8f64-46b49003841a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7bcd775c-fb87-4ffd-be72-aa4957ceb9fc"}}}]}, {"uuid": "cd277a1a-45ef-4295-9a91-09ec9aec78d8", "name": "load_p1rlv453_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6a8a3c7-5165-48b7-8233-30d3af045442"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "795c5ff0-765b-4d2e-84e6-b605b9f21f84"}}}}, {"uuid": "af2dfd1e-d3d1-4abc-8e58-088d954abeb0", "name": "0c037c26-3125-41e7-8397-dae2b1fc74c8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4699462180170992, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3815978523472859, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bb461309-e0cf-4887-9031-9ac78ac63cb4", "name": "2b0e6d4f-78ed-4a16-b402-7009875520fe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "af2dfd1e-d3d1-4abc-8e58-088d954abeb0"}}}]}, {"uuid": "d51fe97e-f43a-4667-a760-d9a9eed3d4b7", "name": "load_p1rlv454_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3493b0ed-43a2-4602-a7ad-a817331c9d8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bb461309-e0cf-4887-9031-9ac78ac63cb4"}}}}, {"uuid": "5cad70c7-ac45-4b90-a5f3-78e154cc8341", "name": "dd000ba0-8605-43d7-8515-81e634f62533_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4699462180170992, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3815978523472859, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fc6fb7d6-1359-476d-97b1-20bd867f3a18", "name": "6598e321-ea38-42c7-a989-a50e7ae0ac62", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5cad70c7-ac45-4b90-a5f3-78e154cc8341"}}}]}, {"uuid": "215467aa-97f1-4ba5-8bcf-bad6a898e4f8", "name": "load_p1rlv454_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3493b0ed-43a2-4602-a7ad-a817331c9d8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fc6fb7d6-1359-476d-97b1-20bd867f3a18"}}}}, {"uuid": "c1266b4d-e8a3-48a2-9297-e10fe963cf5e", "name": "29fc98bb-2656-41f5-ad5e-1431eb3fb30b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5202593896091736, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6973445820856009, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "96cd17e7-f798-45b1-8136-6e07bd96d687", "name": "2bbad14f-f795-44e7-8b67-3c821ac4df2b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c1266b4d-e8a3-48a2-9297-e10fe963cf5e"}}}]}, {"uuid": "f0320455-ed71-4eeb-b7cb-3891fd5c8df6", "name": "load_p1rlv455_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "552153cc-f5be-42ee-9985-9361c2e7e2a1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "96cd17e7-f798-45b1-8136-6e07bd96d687"}}}}, {"uuid": "4a5816d1-5d8a-4d59-9761-844ac1fca02d", "name": "de884caa-1c0a-4d92-9115-9f212e96e999_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5202593896091736, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6973445820856009, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "20c248bc-ee70-493f-abc6-aef541a4bb02", "name": "0837a3bd-373a-4210-b7ca-d37bd7aac7cd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4a5816d1-5d8a-4d59-9761-844ac1fca02d"}}}]}, {"uuid": "e503e50d-78e4-4333-bd39-09478619af1c", "name": "load_p1rlv455_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "552153cc-f5be-42ee-9985-9361c2e7e2a1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "20c248bc-ee70-493f-abc6-aef541a4bb02"}}}}, {"uuid": "6d04a185-16bf-47d6-9f92-deb00c1096f4", "name": "78026fdd-52f3-43d6-bb7e-c54fee37d7d9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.664483224984605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9538644530515166, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "704246ad-9aa3-4b64-8adc-72cdeefbf279", "name": "450c3cf4-a57c-4818-9ed7-c910ce08ddae", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6d04a185-16bf-47d6-9f92-deb00c1096f4"}}}]}, {"uuid": "04d7b81b-9fb7-418b-b8ae-51d232702c4d", "name": "load_p1rlv456_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85f0d94e-c096-4d53-ae05-f0dc59f73d02"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "704246ad-9aa3-4b64-8adc-72cdeefbf279"}}}}, {"uuid": "f8906971-5101-4f75-a721-5b7cc3867d5d", "name": "a6fbb3e3-65df-4eaf-8ea6-1ce7d4ce30c2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.664483224984605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9538644530515166, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bda896e9-bf5f-4151-aea7-4cb9f002a0f3", "name": "0305c1c2-bb42-495e-b37e-c56caa95ae85", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8906971-5101-4f75-a721-5b7cc3867d5d"}}}]}, {"uuid": "b3693e19-7baa-4575-ab10-58ea8a3303e5", "name": "load_p1rlv456_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85f0d94e-c096-4d53-ae05-f0dc59f73d02"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bda896e9-bf5f-4151-aea7-4cb9f002a0f3"}}}}, {"uuid": "07259dfc-789d-432d-b8a8-7201249a0d4a", "name": "f9e0814c-a28f-4273-af2f-71fc3f0ddb91_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.001928314210379, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4572901775510755, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8e28387d-892b-4c4a-9bfc-5d99ddc34b9d", "name": "5ade5781-13d3-48eb-92c9-b1b1b675db52", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "07259dfc-789d-432d-b8a8-7201249a0d4a"}}}]}, {"uuid": "6396f646-0b7b-4db8-905b-1aaa0fc529ac", "name": "load_p1rlv457_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6278f6ee-7332-4de8-9d2c-83bb637f489f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8e28387d-892b-4c4a-9bfc-5d99ddc34b9d"}}}}, {"uuid": "eef9909b-7dfb-4201-ba64-64972a7510b2", "name": "659fa35c-9f5f-4372-8a85-75793de72145_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.001928314210379, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4572901775510755, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f0beaee8-0dff-41be-8079-7008b9f38793", "name": "39099389-cdfc-4a1f-816c-c93dfa19271a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eef9909b-7dfb-4201-ba64-64972a7510b2"}}}]}, {"uuid": "cd573da9-d64f-4198-8f46-34a079f6602d", "name": "load_p1rlv457_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6278f6ee-7332-4de8-9d2c-83bb637f489f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f0beaee8-0dff-41be-8079-7008b9f38793"}}}}, {"uuid": "c788b54e-b76d-42bb-b55d-f9517ddd652b", "name": "fdfcd836-32ea-4c57-a20d-a8d0068a30d3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.24613321897865, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9528039237137753, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f06e3d1c-158f-416f-a682-7a7e66916b4c", "name": "2600ca77-2070-413e-9efb-f80804cb32fe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c788b54e-b76d-42bb-b55d-f9517ddd652b"}}}]}, {"uuid": "33524da1-876d-4466-9090-b54091e6186f", "name": "load_p1rlv458_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec66e302-748d-4300-ba65-719de0a906bb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f06e3d1c-158f-416f-a682-7a7e66916b4c"}}}}, {"uuid": "00b54568-a399-4168-b6b2-108bddace79b", "name": "3684c6ad-023a-42d3-be59-ed89bf121656_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.24613321897865, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9528039237137753, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2a2dfb4e-141c-4d8d-a7de-4dad5ba04eb7", "name": "05729729-e11a-4080-8e71-641b55183fda", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "00b54568-a399-4168-b6b2-108bddace79b"}}}]}, {"uuid": "c1a77fe8-1909-4bc7-ae97-94b06c52435b", "name": "load_p1rlv458_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec66e302-748d-4300-ba65-719de0a906bb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2a2dfb4e-141c-4d8d-a7de-4dad5ba04eb7"}}}}, {"uuid": "a03db4c5-93b6-4bd5-8db4-6a563dcdb30e", "name": "6aa860cd-622e-4014-af12-abc266d26b30_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.502751049099443, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7555421856436744, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ba26bf17-ab63-4273-a0bb-faf9bad4de4c", "name": "717ae0b6-4d1f-464a-a299-f077fbb35b0a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a03db4c5-93b6-4bd5-8db4-6a563dcdb30e"}}}]}, {"uuid": "f23ab323-54c8-435f-b1fd-8e60cf8cd52c", "name": "load_p1rlv459_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c112196-bcbc-41bc-99a9-f3657c335c7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ba26bf17-ab63-4273-a0bb-faf9bad4de4c"}}}}, {"uuid": "8ef17114-2bb3-45d9-841e-3bd09e0e7c5f", "name": "90727a7c-dec7-417b-b2f0-57aab2169b89_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.502751049099443, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7555421856436744, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3a502be6-0db3-4667-b815-6a8ee1a44e72", "name": "4a9ecb98-9a3c-4d9b-a503-5e0e697e9acd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ef17114-2bb3-45d9-841e-3bd09e0e7c5f"}}}]}, {"uuid": "f800f59e-b573-4dfb-8d51-8b8de0ced0be", "name": "load_p1rlv459_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c112196-bcbc-41bc-99a9-f3657c335c7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3a502be6-0db3-4667-b815-6a8ee1a44e72"}}}}, {"uuid": "e36a1032-84f7-47fb-99f7-ba68f0b1c98f", "name": "f9131d78-d7bf-409d-804a-fc58fdaac44d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8202631342288826, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.26720803692022926, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0cf0611e-cc09-4f7e-a2bd-4fd7c593d2f4", "name": "0e0565b4-bd83-4f37-81b9-95f041a12d3e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e36a1032-84f7-47fb-99f7-ba68f0b1c98f"}}}]}, {"uuid": "bb55e834-c0df-4bda-8242-dcccf3fe15eb", "name": "load_p1rlv460_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76b212f9-2e27-4064-a2c5-079786afb1d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0cf0611e-cc09-4f7e-a2bd-4fd7c593d2f4"}}}}, {"uuid": "2b4a72cb-bb3d-4bc4-bd92-709af163a462", "name": "928a7425-e29f-43af-abfa-86f7dc12bd20_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8202631342288826, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.26720803692022926, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "86cc4222-c03b-482f-90aa-46d44bb2aeef", "name": "9df527a7-87df-4771-bbfc-7d7d2a3f0eff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2b4a72cb-bb3d-4bc4-bd92-709af163a462"}}}]}, {"uuid": "3071b825-5459-4be8-8b76-f333c316f4c7", "name": "load_p1rlv460_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76b212f9-2e27-4064-a2c5-079786afb1d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "86cc4222-c03b-482f-90aa-46d44bb2aeef"}}}}, {"uuid": "1681dc0a-7a40-434e-8dba-1f19db51925a", "name": "bbe8984b-a62b-45d1-b9f7-12adcba1965e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4622944887503224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10483650830237357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5152946d-17ad-452a-8d50-3ab5b14d25ec", "name": "c3dc8d70-ae93-40ba-b524-b4d321e9f59f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1681dc0a-7a40-434e-8dba-1f19db51925a"}}}]}, {"uuid": "77243974-dd20-4014-b17d-913466af3faf", "name": "load_p1rlv461_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76dd0f1b-4109-4707-a547-f0ab1b6e148f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5152946d-17ad-452a-8d50-3ab5b14d25ec"}}}}, {"uuid": "7578199c-24c3-47ee-8412-ae5e4b092da4", "name": "5bdbdf12-504c-40f1-947d-aa28ee8f89ae_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4622944887503224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10483650830237357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1af4b0d4-e28b-424b-9db1-b7e5869961ab", "name": "6beb972c-9312-4ba8-be20-e79b4ada60e2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7578199c-24c3-47ee-8412-ae5e4b092da4"}}}]}, {"uuid": "a432c673-e52c-41e5-9676-f3fb7b3a04af", "name": "load_p1rlv461_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76dd0f1b-4109-4707-a547-f0ab1b6e148f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1af4b0d4-e28b-424b-9db1-b7e5869961ab"}}}}, {"uuid": "74ed2102-5079-49a3-961d-c854ee51c3cf", "name": "70864144-ffa6-4574-9ecc-4a5c7a3a4b29_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3786182488338723, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5359363058124609, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8b5d7657-81f0-47be-bf22-bebb1d57940b", "name": "caf9718a-fa65-4a51-9361-02be5286f5a6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "74ed2102-5079-49a3-961d-c854ee51c3cf"}}}]}, {"uuid": "f07a0d15-0adc-40e9-aa3c-e16810c2f41e", "name": "load_p1rlv462_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9176da24-7eb5-4b0b-99dd-886c3f974798"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8b5d7657-81f0-47be-bf22-bebb1d57940b"}}}}, {"uuid": "144dbe08-6967-4a00-8ff3-45902a02f650", "name": "8c97b50e-20d1-4d7f-9104-ac19c7d6d5c7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3786182488338723, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5359363058124609, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eb331271-5ef8-45ee-98a5-5e50fea9bb53", "name": "ead2c979-3975-4844-801f-17fa2f40abd4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "144dbe08-6967-4a00-8ff3-45902a02f650"}}}]}, {"uuid": "dbb406a5-e5db-4542-bab9-85656860b5cc", "name": "load_p1rlv462_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9176da24-7eb5-4b0b-99dd-886c3f974798"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eb331271-5ef8-45ee-98a5-5e50fea9bb53"}}}}, {"uuid": "c9b8b2db-fc98-4b73-9372-7b7f56fc06fd", "name": "d38aa64b-6817-4902-b4af-29d0405521ac_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.746284303820433, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6724067157838972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8affc3e7-cc33-47aa-8b64-46f8752acfd2", "name": "832568a2-1b70-43bd-b287-a8ecc7b6008e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9b8b2db-fc98-4b73-9372-7b7f56fc06fd"}}}]}, {"uuid": "bbb2b72b-01b7-4567-a526-08186d132dff", "name": "load_p1rlv463_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff9d9cca-1878-478d-a190-b58c9098f13e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8affc3e7-cc33-47aa-8b64-46f8752acfd2"}}}}, {"uuid": "8493882e-5fe4-4431-b91d-23f766fb3835", "name": "2b44ede7-f0d3-40cf-9ef5-3911382d78f7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.746284303820433, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6724067157838972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7f0a4bf9-4787-4faf-b94f-27e068b9fd23", "name": "ae16dc1f-98a8-471a-8950-fc2f7856f811", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8493882e-5fe4-4431-b91d-23f766fb3835"}}}]}, {"uuid": "0692a8dd-5767-4faa-8ed2-22f06e6818a5", "name": "load_p1rlv463_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff9d9cca-1878-478d-a190-b58c9098f13e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7f0a4bf9-4787-4faf-b94f-27e068b9fd23"}}}}, {"uuid": "90b9c581-1af5-4535-a4e6-5c0bb62f15cd", "name": "589c50c8-66ad-464a-b072-b39b7b629c8e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6697995975485909, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.41657408993223344, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bdff3310-45b0-4cd2-9fbb-76ac2646ed22", "name": "a584c625-4eaf-4447-a60f-da33dbd2aad3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "90b9c581-1af5-4535-a4e6-5c0bb62f15cd"}}}]}, {"uuid": "0ac20aca-a1b8-4ca7-8af5-c18603f14c87", "name": "load_p1rlv464_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "895d0235-3ee6-4f06-9978-9d615d721ebd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bdff3310-45b0-4cd2-9fbb-76ac2646ed22"}}}}, {"uuid": "045e93db-d4b2-4939-8648-121b125682a9", "name": "78c10fdf-2c51-4a7e-b931-5f4249b795a5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6697995975485909, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.41657408993223344, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1836608f-4a1a-4787-a25b-a3e6d90cf0fb", "name": "40119705-7971-4e0c-9403-92879dc6f264", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "045e93db-d4b2-4939-8648-121b125682a9"}}}]}, {"uuid": "70712bd9-cf0d-4d57-b077-5f8c62d2c443", "name": "load_p1rlv464_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "895d0235-3ee6-4f06-9978-9d615d721ebd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1836608f-4a1a-4787-a25b-a3e6d90cf0fb"}}}}, {"uuid": "23f7b572-b420-4566-a98c-b0957a8d3705", "name": "5540f6f1-1e88-429e-8a19-7fbed822563b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.39658717665728, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7677987041236869, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "231541f9-de2a-43fe-8f6d-b1fa16116d70", "name": "68e7af5f-ee63-47a5-9fbc-85802e26b14b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "23f7b572-b420-4566-a98c-b0957a8d3705"}}}]}, {"uuid": "4dbb057b-7a4c-46b0-b651-b7953221ee68", "name": "load_p1rlv474_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e589527-d388-4364-87d2-2f4af1a14509"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "231541f9-de2a-43fe-8f6d-b1fa16116d70"}}}}, {"uuid": "a1f1dbc9-434a-4bda-a3be-744652481039", "name": "c1626b19-390a-438b-bb22-3a67618e84e3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.39658717665728, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7677987041236869, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e05045f9-527b-4c22-b442-7e07341cff95", "name": "16229ae1-0f2c-49a1-b497-ecb55f58586d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a1f1dbc9-434a-4bda-a3be-744652481039"}}}]}, {"uuid": "a2b46400-933c-4daf-8d8a-0db79c8d68c8", "name": "load_p1rlv474_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e589527-d388-4364-87d2-2f4af1a14509"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e05045f9-527b-4c22-b442-7e07341cff95"}}}}, {"uuid": "abf3daaf-3351-4985-aa87-859e07d1038e", "name": "3aa690da-241d-46f3-bb64-0117330bb2c2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0286208645240644, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.052486030755511705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "55898de9-b406-4e16-9444-fc188a12b038", "name": "a5533b53-cc31-4481-93a7-e7a1a2fe8c05", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "abf3daaf-3351-4985-aa87-859e07d1038e"}}}]}, {"uuid": "043b62da-c1eb-4c2e-98d3-267b9c8c764c", "name": "load_p1rlv480_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb55ec0b-b6f7-48a7-8dae-dda95fc34499"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "55898de9-b406-4e16-9444-fc188a12b038"}}}}, {"uuid": "fb39a764-5af3-48da-9038-0a882971a76f", "name": "ae6d6173-39cd-4f95-a615-43c904298ad5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0286208645240644, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.052486030755511705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d268605c-e163-4f4e-a55d-89769662b069", "name": "1ce324fd-d025-41ff-b7a3-c63373a72816", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fb39a764-5af3-48da-9038-0a882971a76f"}}}]}, {"uuid": "f055d64c-5f91-48e8-a3a0-3e00176d588a", "name": "load_p1rlv480_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb55ec0b-b6f7-48a7-8dae-dda95fc34499"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d268605c-e163-4f4e-a55d-89769662b069"}}}}, {"uuid": "01d86a82-6b19-4195-af70-50b97e15278b", "name": "0ce8fcdc-7ce8-4c03-8425-b80a2e092b64_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.344060161619426, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2705527109429713, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "084a4884-2c0f-4fc8-9f28-9ef621e2d7db", "name": "df7e8996-7993-4e74-86f4-57f32eec8344", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "01d86a82-6b19-4195-af70-50b97e15278b"}}}]}, {"uuid": "9d37f739-515f-41ac-95e3-b2c68f6180f2", "name": "load_p1rlv481_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d9e77ad-42c6-4413-96e6-debfed3c442a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "084a4884-2c0f-4fc8-9f28-9ef621e2d7db"}}}}, {"uuid": "55980176-93de-43e5-b013-471374eb1320", "name": "635de8d9-6a09-4e38-b23f-1f821810a8c3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.344060161619426, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2705527109429713, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4ff8aadf-bf74-4264-afc9-654c2b1a74d2", "name": "0a1e8ade-aee1-422e-8547-341980381f49", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "55980176-93de-43e5-b013-471374eb1320"}}}]}, {"uuid": "f6153836-4bed-404c-bdf1-63eb9f24e1f9", "name": "load_p1rlv481_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d9e77ad-42c6-4413-96e6-debfed3c442a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4ff8aadf-bf74-4264-afc9-654c2b1a74d2"}}}}, {"uuid": "aa79d731-94a7-48dd-8d59-5d7e0353e921", "name": "f68c64e8-6ce9-4752-b6f1-f633305cc042_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7771517670040275, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8838563298920215, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "346e1f94-ef53-4328-85d8-3e731cbed0bc", "name": "b543513b-8bbd-4ee6-af00-6b2c45657b65", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aa79d731-94a7-48dd-8d59-5d7e0353e921"}}}]}, {"uuid": "5330f48f-076b-49f1-82a8-aa95d814afc0", "name": "load_p1rlv482_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d4b708f-cc15-4ee3-87e0-4d26fec02f1e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "346e1f94-ef53-4328-85d8-3e731cbed0bc"}}}}, {"uuid": "fa809bda-ab1f-468c-a1c0-00ae4155b327", "name": "1df30ee9-3d2f-4c8e-b8f7-1c8c8560c726_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7771517670040275, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8838563298920215, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "61d43de4-349e-45e0-9fad-ca8b5cb8a96b", "name": "222bd2f6-8ef5-451f-99d4-e12b6a9b7b18", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fa809bda-ab1f-468c-a1c0-00ae4155b327"}}}]}, {"uuid": "d784bc94-505d-48cc-9eb3-5d431ef40017", "name": "load_p1rlv482_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d4b708f-cc15-4ee3-87e0-4d26fec02f1e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "61d43de4-349e-45e0-9fad-ca8b5cb8a96b"}}}}, {"uuid": "1825ac5b-af7c-47f2-9768-71fb16fe3580", "name": "7e3d9b34-b59b-4b5f-80c0-4b6df9e76ec6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.028781788264419, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6709073147144231, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "75baf9e4-7868-4e67-b246-614b1840a719", "name": "1027a59c-2df8-4068-94f2-2a7dce473b00", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1825ac5b-af7c-47f2-9768-71fb16fe3580"}}}]}, {"uuid": "5f58554e-ae27-4ee3-b8ce-2ce2b4da05e1", "name": "load_p1rlv483_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d059a618-6f09-404b-b1a0-0e7aa0c55c45"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "75baf9e4-7868-4e67-b246-614b1840a719"}}}}, {"uuid": "3bc1d7e1-1784-42d6-8c39-e8e06455df71", "name": "4a61aa61-fe56-4b0f-9a5f-2f33c303efd8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.028781788264419, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6709073147144231, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f0079fd6-6054-417f-8616-d1e9750b4fae", "name": "b2202614-2c1e-42be-9eda-0fc84316a583", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3bc1d7e1-1784-42d6-8c39-e8e06455df71"}}}]}, {"uuid": "9a558047-9b01-41d0-848f-110b5dc5a875", "name": "load_p1rlv483_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d059a618-6f09-404b-b1a0-0e7aa0c55c45"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f0079fd6-6054-417f-8616-d1e9750b4fae"}}}}, {"uuid": "7fd86059-1fb0-4850-8383-80f9c0d89b07", "name": "78b7cde0-9788-4784-bda5-b2e87c3762ce_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2cae686a-7690-4c89-87fb-f6411445c88a", "name": "4b8f45ca-515d-4011-beb3-1d7dff9174f4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7fd86059-1fb0-4850-8383-80f9c0d89b07"}}}]}, {"uuid": "0a5c43a0-66a6-47dc-a6a2-81c017f57312", "name": "load_p1rlv484_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fde62b60-c5f6-44d6-b2f2-211c21b02033"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2cae686a-7690-4c89-87fb-f6411445c88a"}}}}, {"uuid": "91f21c3a-09a1-463e-bd18-697a4cef3d1d", "name": "cae84f22-cbc8-4490-87ec-65a09cce4be7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c22693f2-4e3e-4332-90df-348f8224e354", "name": "ed9ef4a6-f1f0-4298-a291-139014d1ed1b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "91f21c3a-09a1-463e-bd18-697a4cef3d1d"}}}]}, {"uuid": "2efcaf50-890a-472b-8585-0b0aed28c88c", "name": "load_p1rlv484_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fde62b60-c5f6-44d6-b2f2-211c21b02033"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c22693f2-4e3e-4332-90df-348f8224e354"}}}}, {"uuid": "7c82752e-6238-4694-b6fc-1de01350b614", "name": "0a2fdbf3-b2e1-4e28-bda9-b206aeef6354_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1427818095792333, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033588044558321, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bede68a2-9953-41f7-81c5-67e173e1f7b5", "name": "b81a309e-cfd3-495d-8bc6-b8876ab86522", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7c82752e-6238-4694-b6fc-1de01350b614"}}}]}, {"uuid": "961d3415-4d1b-469d-ad95-d2fb2cba8f9f", "name": "load_p1rlv485_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d2c379-7e19-46c4-8c6e-533fa9db7764"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bede68a2-9953-41f7-81c5-67e173e1f7b5"}}}}, {"uuid": "c9782cba-ea23-4cc0-8eeb-ab8863e342d1", "name": "e23f1faf-8f46-47c3-9fcb-ecf840026784_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1427818095792333, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033588044558321, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2cbeff2f-e022-4b7d-84c0-a0669e5273fc", "name": "15584f6e-d34b-4bab-a9b2-27de606bf26a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9782cba-ea23-4cc0-8eeb-ab8863e342d1"}}}]}, {"uuid": "71f48568-c9c7-48f3-b31a-c98da55e2867", "name": "load_p1rlv485_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d2c379-7e19-46c4-8c6e-533fa9db7764"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2cbeff2f-e022-4b7d-84c0-a0669e5273fc"}}}}, {"uuid": "ef005c11-6613-4d1f-a3f9-ef1660f354cc", "name": "8574ce8c-c0ac-458f-b3d1-5d56ab2dfd00_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5348201699646123, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21241824123648728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f345581f-8b31-49e3-b909-744fd85f1da8", "name": "2583cce9-86fe-4153-b471-f6f480cd262f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ef005c11-6613-4d1f-a3f9-ef1660f354cc"}}}]}, {"uuid": "d781c621-8a08-4bd9-8932-b022ced80680", "name": "load_p1rlv486_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a54b2228-9e7d-4e6b-939d-ab2765454522"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f345581f-8b31-49e3-b909-744fd85f1da8"}}}}, {"uuid": "8b485a7f-3820-452a-ad3a-dbf638044106", "name": "f82bda5c-6bd7-457a-bd8d-5a3d236abcc9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5348201699646123, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21241824123648728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eb877549-0aa6-41ab-a159-3eb8f8a8d16e", "name": "7ec9eede-273c-464c-8684-5216cab393e3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8b485a7f-3820-452a-ad3a-dbf638044106"}}}]}, {"uuid": "7c85c75e-9c64-411f-b5f6-fc3e067e7dad", "name": "load_p1rlv486_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a54b2228-9e7d-4e6b-939d-ab2765454522"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eb877549-0aa6-41ab-a159-3eb8f8a8d16e"}}}}, {"uuid": "37587ae2-c7e3-4b8e-bc53-2e1bd69f1b94", "name": "dbb8d51a-9d04-47a0-8808-9d984c3f20b9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.735884899619907, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7862059386133167, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2a04339c-e49e-4079-8dfa-72d503319bb3", "name": "ed24707c-33ab-4e77-a007-3fc31e829c35", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "37587ae2-c7e3-4b8e-bc53-2e1bd69f1b94"}}}]}, {"uuid": "caa60bdc-63e7-41df-9f56-3480e49958e3", "name": "load_p1rlv487_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2d5799-907e-46fd-a389-120aea352775"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2a04339c-e49e-4079-8dfa-72d503319bb3"}}}}, {"uuid": "635823f5-2af2-4722-8628-1c8309c068f0", "name": "53db1c7b-b1ea-4eda-804a-4739b66213c7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.735884899619907, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7862059386133167, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "785d5de7-2553-4f05-8d72-6e79c2b533a0", "name": "de29166c-4d19-4cc6-a3ba-2cfc74254d6d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "635823f5-2af2-4722-8628-1c8309c068f0"}}}]}, {"uuid": "492910aa-850c-43d9-8fd0-a8b444dd4d33", "name": "load_p1rlv487_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2d5799-907e-46fd-a389-120aea352775"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "785d5de7-2553-4f05-8d72-6e79c2b533a0"}}}}, {"uuid": "114a88fc-4cce-4a85-8877-b8af701eb28b", "name": "f66e6768-368c-4b9a-93d1-5bfa67109daa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4382677398578904, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21115535117680156, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "15e403be-c270-4b31-b9ee-89554f382fd3", "name": "3905f176-648c-47db-9614-82224653a856", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "114a88fc-4cce-4a85-8877-b8af701eb28b"}}}]}, {"uuid": "119a4e4a-f6be-4b55-9900-87c023e626f3", "name": "load_p1rlv523_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97c38794-7c60-4ff8-b09b-7503c9604409"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "15e403be-c270-4b31-b9ee-89554f382fd3"}}}}, {"uuid": "494fd173-51a7-443c-8d92-b653a872f414", "name": "343b7015-d5e0-4d33-9063-52885cdf5728_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4382677398578904, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21115535117680156, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c61863b-4b03-449a-ba74-5a0b3b6f1240", "name": "517586d4-15d7-438c-865e-10fa3790e5ad", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "494fd173-51a7-443c-8d92-b653a872f414"}}}]}, {"uuid": "42101e58-1bef-43a2-8cf3-8b619ff04974", "name": "load_p1rlv523_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97c38794-7c60-4ff8-b09b-7503c9604409"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c61863b-4b03-449a-ba74-5a0b3b6f1240"}}}}, {"uuid": "44f33879-a83f-42d3-b0fd-b054eebfa36c", "name": "d5a8bbba-4bf9-4548-b809-990af5652257_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0716401691896973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6949594139700135, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b670fe47-e049-4a45-bd32-37a9bddc3c4a", "name": "c20e5090-9efa-4101-9164-97e4f547dc7b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "44f33879-a83f-42d3-b0fd-b054eebfa36c"}}}]}, {"uuid": "023c8818-27f6-42ae-a0a0-75b5b12371d4", "name": "load_p1rlv524_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bef074be-aac4-4d82-a832-641729756802"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b670fe47-e049-4a45-bd32-37a9bddc3c4a"}}}}, {"uuid": "3eaf7dfa-6b10-49c8-9220-412dd0c53f54", "name": "b174c88c-0b68-4811-a183-e2455e7deccd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0716401691896973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6949594139700135, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7dd02363-2c3f-4a2d-b42a-cf75c83efe12", "name": "babb8a4d-c0a4-4183-bfb7-5f5a6f2d9682", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3eaf7dfa-6b10-49c8-9220-412dd0c53f54"}}}]}, {"uuid": "7490587f-d2a9-4d03-b135-bf1f15912727", "name": "load_p1rlv524_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bef074be-aac4-4d82-a832-641729756802"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7dd02363-2c3f-4a2d-b42a-cf75c83efe12"}}}}, {"uuid": "0daa0bde-626f-4c61-91dc-fd9fcbd0228f", "name": "59d87379-9909-4561-9fe0-803c1cc97921_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6848010607962993, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6615616037111118, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "668bb1d4-8d20-4fc2-b12a-c853b2093b6c", "name": "ef894c10-fdff-4acf-8a4f-28340bd89565", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0daa0bde-626f-4c61-91dc-fd9fcbd0228f"}}}]}, {"uuid": "89affe1d-df30-4472-aa79-d9d41a960af9", "name": "load_p1rlv525_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a42f8b99-82c6-4c90-81ea-6ccb38eacfab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "668bb1d4-8d20-4fc2-b12a-c853b2093b6c"}}}}, {"uuid": "eceeb9ce-cae8-464e-a1dd-f974d4982328", "name": "da7affbb-c986-4a59-aebe-0921c814e735_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6848010607962993, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6615616037111118, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "827c6e55-1c05-4aec-977d-63675c508fce", "name": "0c6e6671-1359-4d87-912d-0245395bea05", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eceeb9ce-cae8-464e-a1dd-f974d4982328"}}}]}, {"uuid": "565dc000-ec57-49d2-b399-cdc496915202", "name": "load_p1rlv525_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a42f8b99-82c6-4c90-81ea-6ccb38eacfab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "827c6e55-1c05-4aec-977d-63675c508fce"}}}}, {"uuid": "6fce8211-ec65-4b35-b79a-3e48952231d3", "name": "3c91c04b-92ea-45f7-9066-7c4023db5805_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9444657359992037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.058006608995704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4c12a34f-4cc3-44ff-b6a1-a2d2e06a2d01", "name": "5e5d11ea-47a7-4336-913a-e6e84156ba69", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6fce8211-ec65-4b35-b79a-3e48952231d3"}}}]}, {"uuid": "702b22c3-6391-4c00-b2a0-213473b1de53", "name": "load_p1rlv526_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ab8e220-faf9-4108-80f8-22d2fe326c3d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4c12a34f-4cc3-44ff-b6a1-a2d2e06a2d01"}}}}, {"uuid": "8612b553-2a6f-4eb5-95d6-19616c0c0001", "name": "1eac6aa3-3aa4-4f02-9e94-8b3f243b0661_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9444657359992037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.058006608995704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d30d2b5d-97a4-4bcd-8926-9437ae9121e2", "name": "2d8fbce5-1be7-41ca-87ed-b35b6f047dba", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8612b553-2a6f-4eb5-95d6-19616c0c0001"}}}]}, {"uuid": "f25a304e-9871-4686-8346-4e54947de4a3", "name": "load_p1rlv526_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ab8e220-faf9-4108-80f8-22d2fe326c3d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d30d2b5d-97a4-4bcd-8926-9437ae9121e2"}}}}, {"uuid": "c4adf770-4bf0-4ff9-b5e8-a2c0b0b0ed8f", "name": "59be0bf8-dd2b-4ee8-86ff-94aae3288264_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6722127407962883, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033140171384262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a6bdab56-e0b0-4621-8573-17afc2217e60", "name": "72ac885e-4a24-491b-bc5f-2df60f7c5985", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c4adf770-4bf0-4ff9-b5e8-a2c0b0b0ed8f"}}}]}, {"uuid": "1f909f54-5f67-4499-805b-268740afd001", "name": "load_p1rlv531_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32a1d9d7-31c7-4def-88d4-e4d41bd21572"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a6bdab56-e0b0-4621-8573-17afc2217e60"}}}}, {"uuid": "d0306536-ef63-46b5-8ad7-b0c2012c02ce", "name": "e6f65fcf-9b46-4b85-b626-363e8e3abf2c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6722127407962883, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033140171384262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a5029a49-6811-4590-9b37-08466159575e", "name": "8ba2dbc3-975d-4a74-9ad2-aab7450cacc3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d0306536-ef63-46b5-8ad7-b0c2012c02ce"}}}]}, {"uuid": "d29693fc-93cc-4dcb-a81e-ec915a22a887", "name": "load_p1rlv531_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32a1d9d7-31c7-4def-88d4-e4d41bd21572"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a5029a49-6811-4590-9b37-08466159575e"}}}}, {"uuid": "ff1ce328-5ff0-4a6a-8cc3-720b36e308db", "name": "3901e228-d7d3-4c2b-9623-61fcdd03d1d2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.813063869628266, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3555509200852155, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aa62e060-7c3f-4658-a5bb-6ac27d8eab7e", "name": "df21c81a-f687-4bfe-9a36-e095194a10cf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ff1ce328-5ff0-4a6a-8cc3-720b36e308db"}}}]}, {"uuid": "1bf2ee86-4b3a-4a51-bd37-3c02cc5b2eb2", "name": "load_p1rlv532_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1362feeb-2e2c-4dd1-9f49-239c952c6120"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aa62e060-7c3f-4658-a5bb-6ac27d8eab7e"}}}}, {"uuid": "2d4d05d7-da58-4665-ad42-9d5aaf1c1cc8", "name": "c15b620e-3633-49f2-946b-5e9f3ff7ee89_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.813063869628266, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3555509200852155, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f2a566e1-d88c-4f40-93e4-eb51f9da04d1", "name": "99fd0bef-ba99-4d29-ab3f-d0833baaa501", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2d4d05d7-da58-4665-ad42-9d5aaf1c1cc8"}}}]}, {"uuid": "4bbb646b-f5e5-434a-9150-ae55074d0217", "name": "load_p1rlv532_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1362feeb-2e2c-4dd1-9f49-239c952c6120"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f2a566e1-d88c-4f40-93e4-eb51f9da04d1"}}}}, {"uuid": "d10892f4-2562-4589-abbb-e58c3bbbdbe5", "name": "9dcb1517-15a2-4fcd-949e-c7735a62b8eb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.789788128831495, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 5.104197877675544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d15b6add-9538-4b27-8b4f-eebe82806984", "name": "67e36378-dce1-4fd2-9824-8f9da766bd2c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d10892f4-2562-4589-abbb-e58c3bbbdbe5"}}}]}, {"uuid": "ad822df3-0d76-4929-945d-38f5589067a4", "name": "load_p1rlv533_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f79bc5f-375f-4ecd-b828-eb7b137d7cab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d15b6add-9538-4b27-8b4f-eebe82806984"}}}}, {"uuid": "ae02b387-1fd5-4a79-8eed-9a740d62b494", "name": "4823141d-b517-4d47-9c11-5a9d94ba773f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.789788128831495, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 5.104197877675544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "99541b60-fd2b-4302-bed5-43ba04e59d08", "name": "8099a6a3-dd55-4a38-a314-51295e3bfa2a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ae02b387-1fd5-4a79-8eed-9a740d62b494"}}}]}, {"uuid": "c2badedc-6ebd-477c-9ff0-9d83cd96671f", "name": "load_p1rlv533_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f79bc5f-375f-4ecd-b828-eb7b137d7cab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "99541b60-fd2b-4302-bed5-43ba04e59d08"}}}}, {"uuid": "6fd8c910-05ab-4e2e-96ca-a0bf62a01f30", "name": "8d91e304-d583-4a4b-862e-370c05d9fbe4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.504585200899067, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1614896338945686, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "90ff893c-5696-4cba-a481-4a0bb14f3407", "name": "ae047cdb-aeef-4a48-a4c9-b5f1e0c2c7c3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6fd8c910-05ab-4e2e-96ca-a0bf62a01f30"}}}]}, {"uuid": "43ed6dc8-dc77-4444-bf68-f73ff89a3407", "name": "load_p1rlv534_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0eb7074c-0745-4089-9329-aa3495f9b460"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "90ff893c-5696-4cba-a481-4a0bb14f3407"}}}}, {"uuid": "cedc9d19-d4d6-4694-a37c-887b76cad22f", "name": "9064d56b-453f-427f-98e9-e6bbff3cbfc1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.504585200899067, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1614896338945686, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3a43066d-745a-46de-982f-db83487f1a5f", "name": "d5034cec-1823-4361-8099-fa7676d8340e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cedc9d19-d4d6-4694-a37c-887b76cad22f"}}}]}, {"uuid": "d6d0bf46-ec50-4d26-b2d2-9fbf24a065cb", "name": "load_p1rlv534_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0eb7074c-0745-4089-9329-aa3495f9b460"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3a43066d-745a-46de-982f-db83487f1a5f"}}}}, {"uuid": "8eb73e5a-26ba-49e3-87b4-22016ac4eb9d", "name": "12013ea5-b812-4b9b-ad08-995006bf8ba9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.469077677978515, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3943727551399522, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b5b64d97-745a-4e70-b8d7-dce5eb3aadfc", "name": "ae3f01dd-2c40-41ef-bdf2-e9af34d6c3e7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8eb73e5a-26ba-49e3-87b4-22016ac4eb9d"}}}]}, {"uuid": "5a3c7273-5a95-4fd9-9e3a-4abfb773fbd2", "name": "load_p1rlv535_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9cc91945-564c-4ace-bb53-77150b107b41"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b5b64d97-745a-4e70-b8d7-dce5eb3aadfc"}}}}, {"uuid": "315291bc-784c-4b13-8505-fd4e1186ae77", "name": "9a714b62-4a2c-4c1d-97c4-7b429b3fffa9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.469077677978515, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3943727551399522, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eaa12b68-16e4-4231-8b3c-10991027b469", "name": "544f1730-6a8c-4030-83ff-11bc4f5f839f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "315291bc-784c-4b13-8505-fd4e1186ae77"}}}]}, {"uuid": "c7984dc5-3d90-44ff-9829-6ac742cd1eed", "name": "load_p1rlv535_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9cc91945-564c-4ace-bb53-77150b107b41"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eaa12b68-16e4-4231-8b3c-10991027b469"}}}}, {"uuid": "a6ace854-9e20-4e34-a8ac-01f0302fcf6d", "name": "43c90ffd-1e6d-4ea6-aada-9d1a91bf8efe_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.363394523648868, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.5065914416455906, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "065f8d03-acd9-4aef-bf32-ec679cb85d63", "name": "a3ed8f2e-1670-44f9-8eae-31627a7f6e4b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a6ace854-9e20-4e34-a8ac-01f0302fcf6d"}}}]}, {"uuid": "0255150b-1a31-4522-8e00-e52cf5303f41", "name": "load_p1rlv536_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2ea78a8-b9c5-4760-b153-51b45565069e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "065f8d03-acd9-4aef-bf32-ec679cb85d63"}}}}, {"uuid": "5c656de1-ba9d-489b-ae10-b9b2cc439b5b", "name": "7e21c187-648b-45f5-8192-47fa6cd85fdf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.363394523648868, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.5065914416455906, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9103a65d-75a8-4b3c-b9ff-c75118cc02df", "name": "daf7cc08-4973-45f6-9c31-f9245ec99d6f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5c656de1-ba9d-489b-ae10-b9b2cc439b5b"}}}]}, {"uuid": "c2ee4201-1d4a-4e30-aacf-9278043885fc", "name": "load_p1rlv536_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2ea78a8-b9c5-4760-b153-51b45565069e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9103a65d-75a8-4b3c-b9ff-c75118cc02df"}}}}, {"uuid": "0ca2ed02-9ad9-4b9d-9119-90d61a8f442c", "name": "d67ef7d5-94b0-4f8e-ab83-8624470c1e4e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.116603176693932, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3416039415731394, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e5767b74-2bf6-4ae0-acb8-f7db26c54e9d", "name": "fb42b4a2-841e-4022-a801-c14a2c0472a3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0ca2ed02-9ad9-4b9d-9119-90d61a8f442c"}}}]}, {"uuid": "72b2862e-3870-432b-ace8-81c712ed9d0d", "name": "load_p1rlv537_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9f2dfc9e-0b72-4465-b46a-d4e2a7a08f64"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e5767b74-2bf6-4ae0-acb8-f7db26c54e9d"}}}}, {"uuid": "23162cba-e334-4c24-8a3d-fe1db1c34086", "name": "9c924ee9-38fd-4520-9b2c-6cb755f2ff7e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.116603176693932, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3416039415731394, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "887a9b49-4c57-496a-900a-ca04d7b633c4", "name": "e54f1c45-bd2d-438b-8427-ecfd4fe61f5f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "23162cba-e334-4c24-8a3d-fe1db1c34086"}}}]}, {"uuid": "cc0d6925-8787-4d18-8616-fbf30f6c7a5a", "name": "load_p1rlv537_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9f2dfc9e-0b72-4465-b46a-d4e2a7a08f64"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "887a9b49-4c57-496a-900a-ca04d7b633c4"}}}}, {"uuid": "f479d563-a28f-487c-aba5-5b707ed429ad", "name": "ca60cbb9-048c-4e48-890a-7f6fbbe22e57_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6767459289154356, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5300288174067083, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "15daf489-d6f4-44b4-8486-5ef3e50832ad", "name": "0e758f65-c58a-4d6f-8f86-94670c97cafc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f479d563-a28f-487c-aba5-5b707ed429ad"}}}]}, {"uuid": "439e259e-fd7b-4f6b-87d9-7e0edc642f0a", "name": "load_p1rlv588_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75628d41-a82d-4425-8aa2-9f377c771a4c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "15daf489-d6f4-44b4-8486-5ef3e50832ad"}}}}, {"uuid": "0fbd767f-ece8-4ab5-ac8f-0e3782a2ad01", "name": "24e1c251-d056-4a30-bc82-aa0495716368_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6767459289154356, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5300288174067083, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a3aa04d-8ef0-49a2-ae2e-c077b3917d37", "name": "94f5cf50-5df4-4976-a4e9-e867721ce02b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0fbd767f-ece8-4ab5-ac8f-0e3782a2ad01"}}}]}, {"uuid": "3273b0f0-7ce3-4acf-ac66-549e19fb080b", "name": "load_p1rlv588_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75628d41-a82d-4425-8aa2-9f377c771a4c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0a3aa04d-8ef0-49a2-ae2e-c077b3917d37"}}}}, {"uuid": "5454428d-4b56-4c90-907c-d2e9f84a7cfd", "name": "c60191c3-09f3-420e-8bb1-27609dba5428_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8288850538480296, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31695217299610473, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "656c4d3a-9a01-4536-a830-009e8a1c604a", "name": "49d4c517-8c33-4849-91f9-ddd6d490ca31", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5454428d-4b56-4c90-907c-d2e9f84a7cfd"}}}]}, {"uuid": "6c13ec2c-acf6-4759-8425-ea576533c0dc", "name": "load_p1rlv589_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a1c60be-f1a1-48d6-b396-4cca6d8c4e62"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "656c4d3a-9a01-4536-a830-009e8a1c604a"}}}}, {"uuid": "ec435995-213c-4d1e-9b6b-df574871d42d", "name": "40b103c5-1c82-4aee-970a-e97519bb40a7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8288850538480296, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31695217299610473, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "faf98a77-df0a-477b-9f0f-6c363b5d2123", "name": "d7863b9b-b520-4877-b8bb-f9ef347b1395", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ec435995-213c-4d1e-9b6b-df574871d42d"}}}]}, {"uuid": "5c7d4191-8a3a-41c7-96f9-0bf89787fb72", "name": "load_p1rlv589_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a1c60be-f1a1-48d6-b396-4cca6d8c4e62"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "faf98a77-df0a-477b-9f0f-6c363b5d2123"}}}}, {"uuid": "3beaa7fe-e44e-44c0-8550-d2dae7715ac7", "name": "790e25fc-e449-4b27-ac54-1c45374122f5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.696455257947775, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.26943121901999684, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9a4ea290-c792-4ca9-8131-861a4fe68281", "name": "7302f3af-6f22-4f34-8c25-ece13254bfd8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3beaa7fe-e44e-44c0-8550-d2dae7715ac7"}}}]}, {"uuid": "7af173ca-da42-4ca5-b075-bdda3d3b89b8", "name": "load_p1rlv590_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81ce208e-7244-418a-9867-b55b95ba0716"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9a4ea290-c792-4ca9-8131-861a4fe68281"}}}}, {"uuid": "a849ebcb-fdce-4c2e-9923-7e6dd4671f26", "name": "aa41234b-e5d6-46df-bfa3-f936d97f3b39_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.696455257947775, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.26943121901999684, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "63e9d6da-3858-4395-859b-5e91c85df054", "name": "2aba41cc-ff74-4ae2-8f3c-83d6584d1cdc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a849ebcb-fdce-4c2e-9923-7e6dd4671f26"}}}]}, {"uuid": "8821a99d-8519-45d6-8371-606244795fe4", "name": "load_p1rlv590_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81ce208e-7244-418a-9867-b55b95ba0716"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "63e9d6da-3858-4395-859b-5e91c85df054"}}}}, {"uuid": "e23c6472-6af6-4c1e-932d-82123696e1c7", "name": "9f2ff2ae-cb4c-4205-874f-eb54aa1f32c9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.201469129926609, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0819349187657892, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6ed963ec-d8f3-47a6-b9ef-1624186b18da", "name": "ed5a8730-72c7-42e7-accc-d7028a2d3820", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e23c6472-6af6-4c1e-932d-82123696e1c7"}}}]}, {"uuid": "cbc47274-6a9a-4433-b62e-9b0e76aa835d", "name": "load_p1rlv657_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e58890e-e6ce-4dda-91c0-5ccfdb5c420d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6ed963ec-d8f3-47a6-b9ef-1624186b18da"}}}}, {"uuid": "65b73121-cc40-40d2-bddb-6b806f9c9c6d", "name": "eb47a207-eec2-4443-8388-f1644c875527_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.201469129926609, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0819349187657892, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d759b4b2-abec-4247-9cdb-3a0eafa5c792", "name": "d19accf4-becc-4df4-b130-93ba848b0f46", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "65b73121-cc40-40d2-bddb-6b806f9c9c6d"}}}]}, {"uuid": "abab5b2f-4b1c-487f-9c44-2e6d023e44f8", "name": "load_p1rlv657_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e58890e-e6ce-4dda-91c0-5ccfdb5c420d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d759b4b2-abec-4247-9cdb-3a0eafa5c792"}}}}, {"uuid": "0adb4448-1fc9-4ca0-aaab-5784dc663298", "name": "03cf9e18-143d-46fa-b23a-2636cc112a71_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1427818095792333, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033588044558321, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7ecc59f0-062e-4ed5-8351-d96ea59cb8f0", "name": "2961c013-da08-4474-ac53-1bd736e3b497", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0adb4448-1fc9-4ca0-aaab-5784dc663298"}}}]}, {"uuid": "997296ac-dae1-4e24-91df-20a54b89fd04", "name": "load_p1rlv660_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15751ee2-6783-472f-ad57-ec978234fec4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7ecc59f0-062e-4ed5-8351-d96ea59cb8f0"}}}}, {"uuid": "930ffc53-d75a-41a4-8954-7b674d2f4af9", "name": "107ff0d1-7f72-41fb-ae12-5f0d4767108e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1427818095792333, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033588044558321, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "67c3a1d4-fc5a-4a0c-8e6e-b8450ea2d0db", "name": "25c8bf86-cc0a-427c-9964-cf4625f8a763", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "930ffc53-d75a-41a4-8954-7b674d2f4af9"}}}]}, {"uuid": "acb5b681-5b80-45dc-b349-c71b951c0130", "name": "load_p1rlv660_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15751ee2-6783-472f-ad57-ec978234fec4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "67c3a1d4-fc5a-4a0c-8e6e-b8450ea2d0db"}}}}, {"uuid": "73e32d34-7add-44a2-ad8b-44f65d59b253", "name": "78b53566-5bcd-4798-971c-7e9eda98137f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7935386970404408, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "353c28a6-2d33-4062-9cb5-cdaa5812041f", "name": "7868a77f-5078-42de-8c51-9bfb7ac7066e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "73e32d34-7add-44a2-ad8b-44f65d59b253"}}}]}, {"uuid": "00ee95d8-2b16-4183-adf1-e90910dbd1d1", "name": "load_p1rlv672_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb25bf05-ce7f-405a-8c17-fd166748f7d3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "353c28a6-2d33-4062-9cb5-cdaa5812041f"}}}}, {"uuid": "454c48ee-7a4d-4380-8af5-b777bf2faf5a", "name": "be5dac99-946a-4df5-8952-d1147d3fdd3b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7935386970404408, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "67770ecd-bc51-43f6-a467-df322344d97f", "name": "9b7192a2-8782-4dd6-925b-2fd55240b789", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "454c48ee-7a4d-4380-8af5-b777bf2faf5a"}}}]}, {"uuid": "2539222d-42f5-4f63-97e7-8c79633002cd", "name": "load_p1rlv672_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb25bf05-ce7f-405a-8c17-fd166748f7d3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "67770ecd-bc51-43f6-a467-df322344d97f"}}}}, {"uuid": "8a2565fc-2d10-411c-8b58-83ef9b8ba177", "name": "623d7d87-a72d-40d7-b15b-85211aeb8f62_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6873327290171372, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.38872845841522474, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "943ccbbf-545d-4d49-9fd9-da21451999ea", "name": "a0ff9f0f-f8db-4490-bb2a-c6659b925e09", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a2565fc-2d10-411c-8b58-83ef9b8ba177"}}}]}, {"uuid": "c22f9cd1-7aeb-4504-8fde-e07798bc325c", "name": "load_p1rlv673_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31d3267c-7020-4660-9a0b-49cd9d94a5d0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "943ccbbf-545d-4d49-9fd9-da21451999ea"}}}}, {"uuid": "52af43a7-2e10-476d-8f79-b64cc7623bfb", "name": "afc205a7-9f2d-4fd7-b294-a779ae841c7c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6873327290171372, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.38872845841522474, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "45401b66-ff96-4eea-9815-3750c71f19fe", "name": "2210476a-d427-48ac-aade-1e24916762a3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "52af43a7-2e10-476d-8f79-b64cc7623bfb"}}}]}, {"uuid": "56dd86e6-118f-4e7b-be9e-80e878193209", "name": "load_p1rlv673_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31d3267c-7020-4660-9a0b-49cd9d94a5d0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "45401b66-ff96-4eea-9815-3750c71f19fe"}}}}, {"uuid": "f23b238e-c41b-443f-976a-5439245d3616", "name": "282b9f7a-558f-4bae-be6b-4b852c874a38_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.629144238694082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9654448182756213, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1669e9ce-f614-4955-a87e-dd5775809296", "name": "465f7b3a-9ee2-4371-a88c-221f1773518a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f23b238e-c41b-443f-976a-5439245d3616"}}}]}, {"uuid": "bbeff04d-d4e6-49a0-8728-228f48fafd80", "name": "load_p1rlv674_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "449992d6-a91b-40ea-9792-5166a5f2c849"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1669e9ce-f614-4955-a87e-dd5775809296"}}}}, {"uuid": "697cc389-c07a-4dc3-86ea-c2559e23b687", "name": "413ebfd2-b99c-47df-90c6-dc5d1d8ea19e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.629144238694082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9654448182756213, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d1530a61-86d4-4018-bd0f-dcb9c860acb7", "name": "f8554fd1-2ba0-4cc7-b987-61922233324b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "697cc389-c07a-4dc3-86ea-c2559e23b687"}}}]}, {"uuid": "2a50a4d9-31db-4326-8b24-51ddf0b96e18", "name": "load_p1rlv674_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "449992d6-a91b-40ea-9792-5166a5f2c849"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d1530a61-86d4-4018-bd0f-dcb9c860acb7"}}}}, {"uuid": "e4d98caf-81e1-4441-b631-5c089e5d1282", "name": "a82f2924-5745-42c2-b066-45d94daed215_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2527429497469504, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5005012096685874, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1df1739a-2fb0-45e1-9b23-8363bbc5125c", "name": "df7aed15-398f-410c-829d-3b9905adf57a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e4d98caf-81e1-4441-b631-5c089e5d1282"}}}]}, {"uuid": "ede5311a-13dd-4156-8805-07596031707f", "name": "load_p1rlv716_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "93069f0f-fce7-47cd-b7b3-77e861f59573"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1df1739a-2fb0-45e1-9b23-8363bbc5125c"}}}}, {"uuid": "58392726-d0ac-4fe6-9dba-23581fc55985", "name": "f9fbe0ae-67ea-4039-9754-89cd2da347b0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2527429497469504, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5005012096685874, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2b89be86-388c-400b-b82c-a5e26babb039", "name": "acacb8f3-dd51-4dc1-9b99-7c14d0cd1ba5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58392726-d0ac-4fe6-9dba-23581fc55985"}}}]}, {"uuid": "1f87880a-e02f-4c82-a483-7f3d08ad74f0", "name": "load_p1rlv716_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "93069f0f-fce7-47cd-b7b3-77e861f59573"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2b89be86-388c-400b-b82c-a5e26babb039"}}}}, {"uuid": "bf496c73-e70e-423a-96b1-fec14de1cae3", "name": "f310019d-dc68-401e-a608-8f9873831b88_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.916354724025409, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9016755043678467, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ee026057-b475-41b4-9779-c9e655f595e4", "name": "55e3eda6-0059-4f6f-99e1-fd657134df3d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bf496c73-e70e-423a-96b1-fec14de1cae3"}}}]}, {"uuid": "bfa2a69f-a518-48d9-b301-9ecedffbc7df", "name": "load_p1rlv717_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd8fd159-f747-4ee4-a426-787f4eef4b42"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ee026057-b475-41b4-9779-c9e655f595e4"}}}}, {"uuid": "28596690-1a72-4eb3-88be-d63b33a6aa7b", "name": "e4e5404d-c770-4339-b715-c92a48adccff_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.916354724025409, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9016755043678467, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "38f4e1b1-3d21-4665-9b25-7d4717c4cf7d", "name": "588b544f-3513-4e91-b239-0cb86d9d9ab0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "28596690-1a72-4eb3-88be-d63b33a6aa7b"}}}]}, {"uuid": "afeb6c0e-ac4d-455f-aaf8-562288cbf02c", "name": "load_p1rlv717_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd8fd159-f747-4ee4-a426-787f4eef4b42"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "38f4e1b1-3d21-4665-9b25-7d4717c4cf7d"}}}}, {"uuid": "68031fd5-2533-4e56-9d65-f86eb933be4f", "name": "6db53d39-c949-4671-af40-bb2a932b8663_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.786120494572624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2344198860247402, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f056302a-9feb-4ed2-99b8-d266c61b39a6", "name": "af07bc93-3dcf-4220-8b1c-ecada1320a11", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "68031fd5-2533-4e56-9d65-f86eb933be4f"}}}]}, {"uuid": "977afcb1-5009-4ac4-b614-e3ca9da3a132", "name": "load_p1rlv718_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4a1453b-98a3-4c2d-8ac2-c8b2ab1bfa4f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f056302a-9feb-4ed2-99b8-d266c61b39a6"}}}}, {"uuid": "3585aea3-3794-4904-9bea-6f6577ba20d1", "name": "4ebb5e28-2f63-4b4f-b4b3-1e3f25027fba_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.786120494572624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2344198860247402, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f395d072-a839-4ac6-b22a-ba64f15a695f", "name": "dc5bb47e-ac2d-4fd7-9799-2d2244310396", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3585aea3-3794-4904-9bea-6f6577ba20d1"}}}]}, {"uuid": "acd07cca-61e9-4d04-a311-705836ab8e65", "name": "load_p1rlv718_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4a1453b-98a3-4c2d-8ac2-c8b2ab1bfa4f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f395d072-a839-4ac6-b22a-ba64f15a695f"}}}}, {"uuid": "b18f4b09-ed17-44bc-91ed-0c1ab5fd29f0", "name": "352ee402-7303-457c-8250-6c8740280031_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.872791085416893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.761492956317497, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6c62ae6d-d04e-4992-ae3f-25bd74f7a2f5", "name": "5b7571da-3ce0-486f-b952-4b3fea385372", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b18f4b09-ed17-44bc-91ed-0c1ab5fd29f0"}}}]}, {"uuid": "79c3a6fa-cd50-451c-96b7-2b35828c1130", "name": "load_p1rlv719_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3153167-8b4c-40e4-abb7-3bdef86950c3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6c62ae6d-d04e-4992-ae3f-25bd74f7a2f5"}}}}, {"uuid": "446dea59-a20d-4230-9868-466622a8596f", "name": "49bc3b2c-a430-418b-ae9b-1dbfe1acf7da_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.872791085416893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.761492956317497, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ed8a7b8a-0b5f-4835-96b4-03b2e8233240", "name": "022113f8-efad-4ccb-b324-6be956eedc22", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "446dea59-a20d-4230-9868-466622a8596f"}}}]}, {"uuid": "5d798181-b869-42ea-ad5c-4ffb250a43c6", "name": "load_p1rlv719_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3153167-8b4c-40e4-abb7-3bdef86950c3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ed8a7b8a-0b5f-4835-96b4-03b2e8233240"}}}}, {"uuid": "78dca5a5-2c84-4ac1-b8e3-d85046b179ac", "name": "4885aac2-d383-42d3-b012-fa12ac7c001b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.000000644073754, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1655557120603839, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b7861d22-0711-4175-8380-6949e323537c", "name": "c240c5ca-e0d0-49f6-89b3-f39f936d3cf4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "78dca5a5-2c84-4ac1-b8e3-d85046b179ac"}}}]}, {"uuid": "ae80bdbe-4444-4eac-97fb-51bcb6cc2d84", "name": "load_p1rlv720_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdbc11b7-5abf-4ff8-8d26-53faf4b1f3f5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b7861d22-0711-4175-8380-6949e323537c"}}}}, {"uuid": "1d863231-f17e-4b90-b3c8-a71a7ff0d81e", "name": "5428a001-da2b-48f0-8ac3-13506a749c4a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.000000644073754, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1655557120603839, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f0bdde55-7be0-4905-8777-cd2aff83f410", "name": "4154317d-cfc9-4a54-9941-94974a1c7930", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1d863231-f17e-4b90-b3c8-a71a7ff0d81e"}}}]}, {"uuid": "0d1c5f25-f550-471e-a519-97e3204a3ce9", "name": "load_p1rlv720_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdbc11b7-5abf-4ff8-8d26-53faf4b1f3f5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f0bdde55-7be0-4905-8777-cd2aff83f410"}}}}, {"uuid": "eb054f98-f757-4381-a754-386a4f692c7e", "name": "cd70e24d-36fb-4c38-9091-a607a7510221_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5041010955030301, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21577690333785765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1769bd12-ea2f-4e78-b9b4-d466df50ed95", "name": "e3a31a47-8ce6-4377-b101-b708d47ee0c4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eb054f98-f757-4381-a754-386a4f692c7e"}}}]}, {"uuid": "90a60c4d-b19b-45e9-88a5-f37644403db8", "name": "load_p1rlv721_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf12b67c-4df5-4dcb-a2e2-6ae2d0f82e65"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1769bd12-ea2f-4e78-b9b4-d466df50ed95"}}}}, {"uuid": "e6ccadcb-551c-4fce-9af8-b2c1ce35e751", "name": "adb54d5f-cca1-41b2-b7f0-30b4ca644bd3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5041010955030301, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21577690333785765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6d569f9f-5b10-4009-a8e9-d27ed169cb1c", "name": "f2aed3a1-839d-4ccd-b083-5939d16814d8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e6ccadcb-551c-4fce-9af8-b2c1ce35e751"}}}]}, {"uuid": "36af70ed-991f-4f4d-a0c6-02bfeb5237a9", "name": "load_p1rlv721_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf12b67c-4df5-4dcb-a2e2-6ae2d0f82e65"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6d569f9f-5b10-4009-a8e9-d27ed169cb1c"}}}}, {"uuid": "5f3616e6-0f56-49dc-962f-5a9371bb503e", "name": "be256f82-a4ca-4c22-aa1c-f53f933a408d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6733980323267108, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22626974414284334, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "900a87a8-5526-4eb4-b5a0-979080a61198", "name": "f62b6131-8890-4ca4-ac96-d20f59ace51b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5f3616e6-0f56-49dc-962f-5a9371bb503e"}}}]}, {"uuid": "ce2e7d49-8d13-4420-86ed-e25fa9f409cb", "name": "load_p1rlv722_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b7c6c65-e18c-4e79-b419-8894deb0d345"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "900a87a8-5526-4eb4-b5a0-979080a61198"}}}}, {"uuid": "91a1f911-9c6e-4f9d-b57a-24870fb2799a", "name": "3ced0a9a-c4e6-4a5a-ac86-9fed36368435_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6733980323267108, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22626974414284334, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8c040eae-447e-41cd-98e3-95b28f9c3636", "name": "9c50eea9-4cd9-45ca-9f4b-53d8c330a52f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "91a1f911-9c6e-4f9d-b57a-24870fb2799a"}}}]}, {"uuid": "af969afc-6753-4848-a059-1b3dd13285ac", "name": "load_p1rlv722_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b7c6c65-e18c-4e79-b419-8894deb0d345"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8c040eae-447e-41cd-98e3-95b28f9c3636"}}}}, {"uuid": "d0e3b089-c79e-4876-95b1-fb7d504380c2", "name": "4948e182-fabc-4164-82d3-ddf56e545b76_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2596055778412756, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4460523908595607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "120e19ed-92c5-4d00-b8b3-c9761ba75852", "name": "a7cc84eb-7b9c-4b97-a044-1f3f2bfadd43", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d0e3b089-c79e-4876-95b1-fb7d504380c2"}}}]}, {"uuid": "cc7beee9-ae31-4720-b679-66236113c044", "name": "load_p1rlv723_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7551be44-a4ca-4edb-b823-6495d163201e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "120e19ed-92c5-4d00-b8b3-c9761ba75852"}}}}, {"uuid": "f56ecadc-4862-4e7b-8afa-2d10acd0e581", "name": "0fde8a58-763b-43d1-93d1-4de9b34f2660_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2596055778412756, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4460523908595607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e82878f4-7239-4c3a-8d86-512ea4be2428", "name": "0b72b0d5-3710-48c1-8165-3fc647a05336", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f56ecadc-4862-4e7b-8afa-2d10acd0e581"}}}]}, {"uuid": "c03cf62f-3808-464a-b0b0-216bc94398b6", "name": "load_p1rlv723_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7551be44-a4ca-4edb-b823-6495d163201e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e82878f4-7239-4c3a-8d86-512ea4be2428"}}}}, {"uuid": "206ccb98-6132-4ee4-9c61-598990f1ef36", "name": "414d01c4-24ab-4828-bed6-9792187e017e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.794005533851084, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6855099409421886, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b839b6ba-2d40-44a3-8a83-1b9c240ff553", "name": "fe0822bd-009c-49aa-8c17-d6519e77523a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "206ccb98-6132-4ee4-9c61-598990f1ef36"}}}]}, {"uuid": "cda0e6a3-6816-4724-9d32-66cf642a638b", "name": "load_p1rlv724_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3658479-7369-4bd9-be54-e7768c93a808"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b839b6ba-2d40-44a3-8a83-1b9c240ff553"}}}}, {"uuid": "ab4a0044-8726-4027-8728-cab4f9c28832", "name": "d9befc77-f563-4e77-8348-4a35a3f6204c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.794005533851084, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6855099409421886, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5013d830-da3a-4cc4-bae0-872873f72f9d", "name": "3179e716-63ce-4f4e-84f7-a115095ff69b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ab4a0044-8726-4027-8728-cab4f9c28832"}}}]}, {"uuid": "32b32edf-0faa-4b81-8ce6-dc1f54bb4230", "name": "load_p1rlv724_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3658479-7369-4bd9-be54-e7768c93a808"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5013d830-da3a-4cc4-bae0-872873f72f9d"}}}}, {"uuid": "b17267ee-47c5-411a-a31b-ebe7f1237538", "name": "8ab8e5d0-1269-44e5-8fbe-90c56e6bea92_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7997673490012955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.772957044307952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "63ea1069-71be-457d-9839-65489224aa34", "name": "55100585-da78-4e58-bb3e-7b5689090e75", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b17267ee-47c5-411a-a31b-ebe7f1237538"}}}]}, {"uuid": "18c72770-ada5-451b-a875-7af3a4e7e5e4", "name": "load_p1rlv725_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2bcbabc-a7fc-4230-8ec1-b6050af9cf58"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "63ea1069-71be-457d-9839-65489224aa34"}}}}, {"uuid": "202490d4-2e13-4030-9563-cd2d19bd3793", "name": "5d799024-2182-434b-a3aa-eb41f7d2d023_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7997673490012955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.772957044307952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2eba0569-eddf-44d2-b873-54968c0ff842", "name": "fc05ed22-e71c-46e6-94df-0433df5a2457", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "202490d4-2e13-4030-9563-cd2d19bd3793"}}}]}, {"uuid": "f7902d74-d4ed-43ba-af65-9db169a096e8", "name": "load_p1rlv725_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2bcbabc-a7fc-4230-8ec1-b6050af9cf58"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2eba0569-eddf-44d2-b873-54968c0ff842"}}}}, {"uuid": "35be8c28-4603-4c6d-b4bd-a972a67044dc", "name": "4020d951-95a0-453f-b69f-2cd0350929b1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.762685564172624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.7175951697927787, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4fefaa1d-8570-4fdd-908d-f3877c473c07", "name": "394b95f6-b12a-4cc1-98de-303c5877fe0a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "35be8c28-4603-4c6d-b4bd-a972a67044dc"}}}]}, {"uuid": "0b358c72-6f60-48ae-8c2c-3c786b5a52fc", "name": "load_p1rlv726_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fdcbc55-681f-4fe5-8142-4945b25f6fef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4fefaa1d-8570-4fdd-908d-f3877c473c07"}}}}, {"uuid": "654ab3ed-1580-4c7a-a3db-4cd47906bb85", "name": "aacb3ee5-917c-4517-b756-44a73b1213d8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.762685564172624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.7175951697927787, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2e4cb72a-c229-4b25-b5c8-012e536eb05a", "name": "d39ceafe-765a-4fa3-bbb0-01872c9a5dc1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "654ab3ed-1580-4c7a-a3db-4cd47906bb85"}}}]}, {"uuid": "bd703703-bee0-41ea-9c5a-2bb2e1a77c77", "name": "load_p1rlv726_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fdcbc55-681f-4fe5-8142-4945b25f6fef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2e4cb72a-c229-4b25-b5c8-012e536eb05a"}}}}, {"uuid": "c9b17eaa-a404-4df1-aa43-fad0d049acac", "name": "914c059f-404a-49d2-be3f-3a4bbfa166d8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.981510789736824, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31377757670385525, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2e07e5a2-10ac-4133-a440-a0264b5555a1", "name": "b7887293-b0cd-4eb6-9448-45496ea31cbc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9b17eaa-a404-4df1-aa43-fad0d049acac"}}}]}, {"uuid": "7a93df03-8bc9-4742-b9f2-132964907df8", "name": "load_p1rlv749_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80983704-a98f-46dc-a09f-700bd7df1a29"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2e07e5a2-10ac-4133-a440-a0264b5555a1"}}}}, {"uuid": "1ccee909-af72-488c-ac95-cf3da56f22d5", "name": "fa888314-932e-4416-ab8a-3efe94677372_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.981510789736824, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31377757670385525, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4465aaeb-7114-4a39-88d9-ae13308d7239", "name": "d2c1e38f-6d88-4622-a3c7-9e43fa043ade", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1ccee909-af72-488c-ac95-cf3da56f22d5"}}}]}, {"uuid": "1748effe-25e9-4eb7-bf52-0121f8ec8725", "name": "load_p1rlv749_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80983704-a98f-46dc-a09f-700bd7df1a29"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4465aaeb-7114-4a39-88d9-ae13308d7239"}}}}, {"uuid": "97595f54-fa68-4bc7-a5d8-08e42f71deb9", "name": "5a922f5f-0a3a-4a86-b0b2-2bd83a97c70e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3612560165719545, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7198526424662817, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2284f4af-57f8-481e-845b-620d59dd587c", "name": "25785f91-6b3b-4678-ab4f-a5c1c5582b2e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "97595f54-fa68-4bc7-a5d8-08e42f71deb9"}}}]}, {"uuid": "4068cc20-6387-452c-b2d9-f20698ada793", "name": "load_p1rlv756_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3c3b0fb-5a5d-439e-a350-b97ba0df41a0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2284f4af-57f8-481e-845b-620d59dd587c"}}}}, {"uuid": "6dfd623a-6445-4a09-814a-c64d2133b497", "name": "78e36fd2-0a28-4227-bc4a-c4a8a7015c3b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3612560165719545, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7198526424662817, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2f73c189-c676-4215-b467-dc29671c2291", "name": "757afc2b-5fc3-49df-86c7-eb3e0da98a49", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6dfd623a-6445-4a09-814a-c64d2133b497"}}}]}, {"uuid": "6ad9daeb-12ab-4094-8f0a-f1d464b428a0", "name": "load_p1rlv756_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3c3b0fb-5a5d-439e-a350-b97ba0df41a0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2f73c189-c676-4215-b467-dc29671c2291"}}}}, {"uuid": "095ab4d6-8a69-462d-a850-f0b13520dbc4", "name": "14aa8b69-3b5d-4b12-9027-e1f27c344633_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.910200682298975, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5555412020426419, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a53fa2df-1c44-4551-970d-eaf3bf4ff3aa", "name": "671c0fa0-40f7-43af-8879-e9ed849c7b38", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "095ab4d6-8a69-462d-a850-f0b13520dbc4"}}}]}, {"uuid": "49bfdc0b-b1f1-4793-a1ee-c23ebccfb7ca", "name": "load_p1rlv764_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e368704b-6c4b-4afb-a577-4b0d7a96dd65"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a53fa2df-1c44-4551-970d-eaf3bf4ff3aa"}}}}, {"uuid": "98e825f3-67b7-4c37-94e4-ba4cd44d1c77", "name": "75b95e6b-993e-49d1-beaf-05ad1485d9dc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.910200682298975, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5555412020426419, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ac754445-1442-4550-905e-8e707d74471b", "name": "cba8842f-933e-489e-addf-3b06dcb6b8f1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "98e825f3-67b7-4c37-94e4-ba4cd44d1c77"}}}]}, {"uuid": "76bba039-59f2-4f78-8883-71aa2de6a56f", "name": "load_p1rlv764_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e368704b-6c4b-4afb-a577-4b0d7a96dd65"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ac754445-1442-4550-905e-8e707d74471b"}}}}, {"uuid": "da122198-fdf4-4f17-91f4-a07f00b0635a", "name": "d2b79295-98d1-4ac5-9fd4-50f63968a697_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4856814769108864, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8267323554826451, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "981253cf-9ec0-46de-96c7-894d0ea481f3", "name": "14cc4b68-7bdb-4ee6-85d8-136e91f1acbc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "da122198-fdf4-4f17-91f4-a07f00b0635a"}}}]}, {"uuid": "bd077c4a-347f-469a-9666-a1ffd44e74e9", "name": "load_p1rlv766_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07381934-8e9b-4447-a330-e8af484331f1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "981253cf-9ec0-46de-96c7-894d0ea481f3"}}}}, {"uuid": "44b0c0d9-18c0-456c-badf-3f0150e3ff71", "name": "376debc5-4871-42ec-a45b-c7ca0f7641fb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4856814769108864, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8267323554826451, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "24537064-7722-4085-ae94-ad0a58eafd75", "name": "a38cdba4-704d-4fa8-ba52-cd2636dd6f24", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "44b0c0d9-18c0-456c-badf-3f0150e3ff71"}}}]}, {"uuid": "cb470b47-d7b1-400f-8605-511c302fd177", "name": "load_p1rlv766_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07381934-8e9b-4447-a330-e8af484331f1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "24537064-7722-4085-ae94-ad0a58eafd75"}}}}, {"uuid": "2d0835b7-8d42-4dbe-bab2-b7cf2bd0a3ce", "name": "c9a27d67-ee66-48b5-9c74-241a63a61769_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7083181921938193, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5666922324635131, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b009a683-06f5-412d-b28a-2d70d330b918", "name": "12fdd19f-c9c9-4712-87a7-0eb4cfeeea43", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2d0835b7-8d42-4dbe-bab2-b7cf2bd0a3ce"}}}]}, {"uuid": "af3c78f3-2c17-4189-920c-66419131c6f5", "name": "load_p1rlv775_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d00977fb-8d2a-44ca-aa9e-034894d6e280"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b009a683-06f5-412d-b28a-2d70d330b918"}}}}, {"uuid": "bfa66587-5224-4964-bf22-adc45a8102b5", "name": "efb56f1f-ea09-462e-bf7a-c0d3aef7d273_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7083181921938193, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5666922324635131, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "af7f6606-be0b-4ffb-9ad5-14dc2b7b129c", "name": "f4304dad-8b4c-4aec-b5ba-69374fbc18a6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bfa66587-5224-4964-bf22-adc45a8102b5"}}}]}, {"uuid": "e98e2389-7cf7-4dd2-92bd-be1be91c4a06", "name": "load_p1rlv775_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d00977fb-8d2a-44ca-aa9e-034894d6e280"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "af7f6606-be0b-4ffb-9ad5-14dc2b7b129c"}}}}, {"uuid": "c647da92-87b1-48a3-92c2-188de6a9533d", "name": "7da23661-24f7-4c1d-84c2-5e0d59552fad_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.779437116944347, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0510023138100544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bba4366b-4b54-4a75-a4b3-4ba63f4de749", "name": "91699525-1af6-4e00-b7c7-5cd4d14db0dd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c647da92-87b1-48a3-92c2-188de6a9533d"}}}]}, {"uuid": "bf3f6187-ae8e-4b4a-bac1-260d3b7c7bba", "name": "load_p1rlv776_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c5b1f75-47c0-45c3-9ef3-f97a445b242e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bba4366b-4b54-4a75-a4b3-4ba63f4de749"}}}}, {"uuid": "ed7c1fbd-90bd-42f8-bdda-65b54bacce7c", "name": "0b724cdf-7e23-40d8-85ef-44b2fef77f36_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.779437116944347, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0510023138100544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "68bafba1-5b2b-40db-b17e-442cca8e5d82", "name": "c9bae9e4-9c6d-4106-81be-52b260b3b36e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ed7c1fbd-90bd-42f8-bdda-65b54bacce7c"}}}]}, {"uuid": "8f8d4df1-5a48-4c4c-b74b-f1c95de4cc03", "name": "load_p1rlv776_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c5b1f75-47c0-45c3-9ef3-f97a445b242e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "68bafba1-5b2b-40db-b17e-442cca8e5d82"}}}}, {"uuid": "0df6d500-fb5a-4499-a196-31a12b23a034", "name": "be8c7f3b-9a68-4c98-9632-9cdbf579b8cb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3483029031483318, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6505451661884267, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b0a276b7-d3fc-4c8f-9da5-216c398babf3", "name": "334fc552-b885-4faa-bb7e-c1332260f2e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0df6d500-fb5a-4499-a196-31a12b23a034"}}}]}, {"uuid": "da976a87-52f4-48fc-b48d-c87ee7f367c3", "name": "load_p1rlv777_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fb1fca8-7985-4356-a8de-7433fef7a454"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b0a276b7-d3fc-4c8f-9da5-216c398babf3"}}}}, {"uuid": "f184f240-c154-4d08-99f3-6d35887d55fc", "name": "a20f9e8b-6285-4a23-bf3c-811d440ca941_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3483029031483318, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6505451661884267, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8fd141ec-66ef-48ae-b92c-051f229c57bd", "name": "88f79e12-1637-4b3c-84a6-497f9c34b51c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f184f240-c154-4d08-99f3-6d35887d55fc"}}}]}, {"uuid": "88825692-476f-466b-852c-5593f1a76bd5", "name": "load_p1rlv777_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fb1fca8-7985-4356-a8de-7433fef7a454"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8fd141ec-66ef-48ae-b92c-051f229c57bd"}}}}, {"uuid": "e3d3a257-3499-4ef3-a6fb-094615787127", "name": "58a200ee-cf6d-4ebd-8eee-13d37cba4efe_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.993849790823018, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8230403105677124, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dbc24d2f-ac5a-4014-9727-f3022d456fe8", "name": "4d093c92-29a0-4276-b2aa-0fc8f4ea3b6d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e3d3a257-3499-4ef3-a6fb-094615787127"}}}]}, {"uuid": "cf15fdf4-d3ca-4b4f-8331-3cfee831711f", "name": "load_p1rlv778_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80d58665-ee8a-4f4e-a906-dc15aa3d8c6f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dbc24d2f-ac5a-4014-9727-f3022d456fe8"}}}}, {"uuid": "ad44b362-b8d0-43f7-88fa-5e95294fc979", "name": "83ad46c7-97e5-41bc-a258-e129c9919c7d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.993849790823018, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8230403105677124, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "af72f8ad-1709-4aa0-bd4f-a57fe996c2b8", "name": "a4c6f312-dfb4-4684-90b7-89d96afcd6e1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ad44b362-b8d0-43f7-88fa-5e95294fc979"}}}]}, {"uuid": "c1643d04-ee94-4c42-a3fa-5a9649da51c2", "name": "load_p1rlv778_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80d58665-ee8a-4f4e-a906-dc15aa3d8c6f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "af72f8ad-1709-4aa0-bd4f-a57fe996c2b8"}}}}, {"uuid": "8fda77fb-2ca6-4aae-833e-2dc48e283d3a", "name": "8f978ad7-6b29-4136-bb49-a260293e3694_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9928270585646484, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0482885249865175, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "be510307-835d-455c-a22a-907e1c4aaf34", "name": "a4e10a40-6b35-4702-b2ef-dff0376c1927", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8fda77fb-2ca6-4aae-833e-2dc48e283d3a"}}}]}, {"uuid": "bd460ab7-6f33-4ad8-bab9-c7975ca760fe", "name": "load_p1rlv779_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fbc761bf-480c-465c-9479-279832c50bc2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "be510307-835d-455c-a22a-907e1c4aaf34"}}}}, {"uuid": "757268af-82cf-4c04-8286-0ce4dfa4b093", "name": "3ee4a450-9481-4eb5-b237-5c5a878e489a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9928270585646484, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0482885249865175, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d89ab889-d4db-4be6-9a90-26f73ba46828", "name": "b35d9fbe-013c-4a1c-83b9-4ab26d855305", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "757268af-82cf-4c04-8286-0ce4dfa4b093"}}}]}, {"uuid": "95c38f40-9c71-4894-8b76-b5299a47976e", "name": "load_p1rlv779_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fbc761bf-480c-465c-9479-279832c50bc2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d89ab889-d4db-4be6-9a90-26f73ba46828"}}}}, {"uuid": "de388c37-805e-46eb-be1f-9964021fb441", "name": "6eb3ddcf-b9b7-46c4-b045-4a3c23614f63_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1813646779377422, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20173832232537287, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7747797d-7399-4cfd-94fb-22f3f4208b34", "name": "cd15d90f-9046-4e94-80cc-c53c23cbcc2d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "de388c37-805e-46eb-be1f-9964021fb441"}}}]}, {"uuid": "e1ef1997-11c2-4bde-9614-10e1366bbfa7", "name": "load_p1rlv780_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20dcf67f-f04f-498a-830d-557ba7b4d867"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7747797d-7399-4cfd-94fb-22f3f4208b34"}}}}, {"uuid": "1d52a042-3b51-466c-b0b9-9793f90674f1", "name": "c6cc7966-7cb6-477f-b0aa-90853888976c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1813646779377422, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20173832232537287, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fb5b0f15-a6a3-4798-9359-04c664a0b337", "name": "de37e0df-b3dc-4372-8ca5-780e264ad2dc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1d52a042-3b51-466c-b0b9-9793f90674f1"}}}]}, {"uuid": "eaefd462-04ca-4b42-9951-de5390cfad14", "name": "load_p1rlv780_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20dcf67f-f04f-498a-830d-557ba7b4d867"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fb5b0f15-a6a3-4798-9359-04c664a0b337"}}}}, {"uuid": "df814907-32b4-490b-85d9-6989f1b2c207", "name": "07d5c973-7b09-4ca3-a5f4-762245e9177f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.774034588817963, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.005441618856208, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6ddcad46-046e-4970-bf6c-38a406e4c1a4", "name": "92d1d692-2e0d-4fc2-88ab-4c4eb635fa55", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "df814907-32b4-490b-85d9-6989f1b2c207"}}}]}, {"uuid": "1de06a56-a8a4-480a-a591-c39f83bf866b", "name": "load_p1rlv781_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98c5ba15-a339-478a-a79f-9298fab16a54"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6ddcad46-046e-4970-bf6c-38a406e4c1a4"}}}}, {"uuid": "ae008260-0220-4b43-bb09-b7a4db443cd6", "name": "9e31d366-716f-40d7-b4b5-357d54d0210a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.774034588817963, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.005441618856208, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f9734d7e-7513-4ce5-a13d-dbc4a0bbddb0", "name": "f503e21e-f463-4a19-8165-e9b74dfdb2bf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ae008260-0220-4b43-bb09-b7a4db443cd6"}}}]}, {"uuid": "2788224b-ffa0-4a6d-a6cb-1f419fca2c75", "name": "load_p1rlv781_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98c5ba15-a339-478a-a79f-9298fab16a54"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f9734d7e-7513-4ce5-a13d-dbc4a0bbddb0"}}}}, {"uuid": "d0474588-6987-431b-b039-72a024c5dae3", "name": "ab458b61-6fdc-437e-81f1-1481b840cc6c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7457942211533133, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8784341351558463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8e6e17c4-cccb-448b-bc16-ddf2158f70eb", "name": "8d70e38a-f57a-492f-9eba-5eb3f9019373", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d0474588-6987-431b-b039-72a024c5dae3"}}}]}, {"uuid": "bdf2cf7b-27a6-44ac-bff7-46e9c4ca9478", "name": "load_p1rlv782_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78a4f54a-017a-41b0-85c8-b3e408c21c08"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8e6e17c4-cccb-448b-bc16-ddf2158f70eb"}}}}, {"uuid": "6c14eafc-a7e2-46ce-9633-4b0777173e5b", "name": "1a084ecc-2ae8-4b1f-89b3-57a1d6d523cb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7457942211533133, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8784341351558463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "99378bc7-2911-4588-b03d-343b24aff733", "name": "b06b5fa9-00fe-479c-9711-aa527b5edbb0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c14eafc-a7e2-46ce-9633-4b0777173e5b"}}}]}, {"uuid": "e354d758-9648-4666-9d70-b77f5f1f4737", "name": "load_p1rlv782_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78a4f54a-017a-41b0-85c8-b3e408c21c08"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "99378bc7-2911-4588-b03d-343b24aff733"}}}}, {"uuid": "b24be7a9-3b59-4dc6-9298-d2905610d3aa", "name": "67db29c6-ad14-4b02-ad74-5ad57266c59e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0085854932437286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7150296414254909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8b88af4f-60ed-40e2-b8bf-1abff861db1e", "name": "12db7d6d-fa2f-4fca-bb8b-337ae132b8d9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b24be7a9-3b59-4dc6-9298-d2905610d3aa"}}}]}, {"uuid": "aade8390-df77-43bb-aaa2-244c12fee2fa", "name": "load_p1rlv783_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d1a96d5-f971-4116-9642-769ef5b97e7c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8b88af4f-60ed-40e2-b8bf-1abff861db1e"}}}}, {"uuid": "d5a5cd6a-c6a5-4fc5-8189-3a3b37c9b27a", "name": "ca63e231-3b8d-41bf-ac0b-0063b1db375a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0085854932437286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7150296414254909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ed040046-fa14-42be-9b37-7f7367b7dd4c", "name": "03707f96-fecf-4a1a-90ac-9a69dad2f714", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d5a5cd6a-c6a5-4fc5-8189-3a3b37c9b27a"}}}]}, {"uuid": "d52c6675-0c5d-4f90-bbac-83a9d5e1fb0a", "name": "load_p1rlv783_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d1a96d5-f971-4116-9642-769ef5b97e7c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ed040046-fa14-42be-9b37-7f7367b7dd4c"}}}}, {"uuid": "619dcfdf-f040-45a9-85f7-1e3ef0ec179a", "name": "7eb8803a-c167-4382-a54b-b2af56d8c932_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.965154260277072, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307595255595673, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50a79a8f-7190-4a2d-9d6d-5523568e51f8", "name": "c2d95147-22cb-4130-980a-eab5c2c596d6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "619dcfdf-f040-45a9-85f7-1e3ef0ec179a"}}}]}, {"uuid": "80dfbff6-7bba-43d8-9d0e-4164c32441c6", "name": "load_p1rlv784_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2823b5b9-bcc3-4b30-9874-89dc33ec80d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50a79a8f-7190-4a2d-9d6d-5523568e51f8"}}}}, {"uuid": "deb8610a-ede2-4a10-9146-967487bff884", "name": "294b3492-4155-4b3e-9a69-ac3490d2a85d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.965154260277072, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307595255595673, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1aef9c37-bb70-4ff6-ba21-a0d54c639258", "name": "aef5eabe-1271-4dde-9863-73bfb164f73a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "deb8610a-ede2-4a10-9146-967487bff884"}}}]}, {"uuid": "913c5b60-19da-4ec3-b487-ec0578ce1904", "name": "load_p1rlv784_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2823b5b9-bcc3-4b30-9874-89dc33ec80d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1aef9c37-bb70-4ff6-ba21-a0d54c639258"}}}}, {"uuid": "c9e7b15c-61f7-4b86-90e4-bfc2aad74f55", "name": "7713e8c5-850d-43cb-a2c3-91f3834f43d7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.948680292874151, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.769988963438003, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "45345969-43ff-4427-b01b-d383cffda331", "name": "1790b739-e6c0-4648-b2ae-649d4abe5778", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9e7b15c-61f7-4b86-90e4-bfc2aad74f55"}}}]}, {"uuid": "3ac66ec1-6fb6-4c36-a2c3-e32d08f7d9ac", "name": "load_p1rlv785_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa98d6c6-7086-4033-a9af-c0a33e802942"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "45345969-43ff-4427-b01b-d383cffda331"}}}}, {"uuid": "fb9f3072-5ef5-48d6-9d07-2d2658810068", "name": "bd9c4191-59de-45a1-814b-d90568788fe8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.948680292874151, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.769988963438003, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "593c1512-b383-4ac8-98a4-827a2fcb93a6", "name": "177fe3d7-2b35-484b-875f-e7d560930137", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fb9f3072-5ef5-48d6-9d07-2d2658810068"}}}]}, {"uuid": "e1ddc0aa-3e8d-4766-a484-644f692e29e1", "name": "load_p1rlv785_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa98d6c6-7086-4033-a9af-c0a33e802942"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "593c1512-b383-4ac8-98a4-827a2fcb93a6"}}}}, {"uuid": "bc760cd2-a200-4bfd-9186-1f7acd7a1a81", "name": "456087ae-8687-410b-a07b-5303e9da9193_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0491915565570302, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1506537762556939, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5b15a43f-f62b-4614-9c68-35ba1f43fb5c", "name": "186ec91e-c15b-4f56-98ff-82750ff6d8db", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bc760cd2-a200-4bfd-9186-1f7acd7a1a81"}}}]}, {"uuid": "d859e8e9-e36f-418b-a618-7d5a905ca868", "name": "load_p1rlv786_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180adab2-e49b-42e9-9aeb-42be0a7686c5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5b15a43f-f62b-4614-9c68-35ba1f43fb5c"}}}}, {"uuid": "3a1c632a-ce42-42cb-ae94-48b8907ff209", "name": "bb5dcfcf-f220-438e-a891-8f1e45366dbb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0491915565570302, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1506537762556939, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aae090e5-66ce-4226-a0dc-088b17d1c483", "name": "c65f9925-017a-4930-8312-dade9bf74b58", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3a1c632a-ce42-42cb-ae94-48b8907ff209"}}}]}, {"uuid": "8dd7c44e-a653-498e-be77-b6b12110969f", "name": "load_p1rlv786_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180adab2-e49b-42e9-9aeb-42be0a7686c5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aae090e5-66ce-4226-a0dc-088b17d1c483"}}}}, {"uuid": "473251b2-1ab4-4ce0-bfea-f97b3f8f6ebb", "name": "79beb2c9-bac5-4287-a9ef-9ce61c94224a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.246762625041277, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42085270345980447, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0891e070-d97c-48e0-ba7d-2b680fa93ce3", "name": "adaf6100-1d2d-4134-a35b-50bc5f41a61d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "473251b2-1ab4-4ce0-bfea-f97b3f8f6ebb"}}}]}, {"uuid": "85d88516-8681-4092-8522-e96e03808247", "name": "load_p1rlv787_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0089ee3-0cb4-434c-adc4-c91a8441ef0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0891e070-d97c-48e0-ba7d-2b680fa93ce3"}}}}, {"uuid": "65eaa6dd-e9ea-4531-b49b-9e6c44dfb463", "name": "fc3a09c9-d1fc-47ad-ba9f-e05638d984b6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.246762625041277, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42085270345980447, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5183e717-19d2-4093-a229-bfdecdd6a6b7", "name": "57ceeb5c-7caa-4188-ac3e-484dd9a20a93", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "65eaa6dd-e9ea-4531-b49b-9e6c44dfb463"}}}]}, {"uuid": "fa119cc4-4020-42a3-bed6-cb4c53fe15f7", "name": "load_p1rlv787_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0089ee3-0cb4-434c-adc4-c91a8441ef0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5183e717-19d2-4093-a229-bfdecdd6a6b7"}}}}, {"uuid": "7eb3f9c1-caf9-45b3-854a-b2e7498e6012", "name": "caa89576-3694-45c2-b0d2-dfa67d478a27_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8660061383019082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.44544683702444765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "30ce92a9-817f-477c-a08d-b1c98ef75f61", "name": "1f49a407-37ad-484a-8b93-f026dedbc504", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7eb3f9c1-caf9-45b3-854a-b2e7498e6012"}}}]}, {"uuid": "a6ef7793-92d0-4190-9487-746bd46b1fe3", "name": "load_p1rlv788_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9f470d9-6ead-4413-ad8a-7ccc69ae9237"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "30ce92a9-817f-477c-a08d-b1c98ef75f61"}}}}, {"uuid": "1fe997d5-481e-4bb5-886a-36f042ab7a4a", "name": "76064b24-cdad-4a93-b0aa-69817f67638c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8660061383019082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.44544683702444765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4b9db413-91c2-4b76-9e16-748421872017", "name": "f135eded-859b-48d6-a770-7d6ce70bceb3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1fe997d5-481e-4bb5-886a-36f042ab7a4a"}}}]}, {"uuid": "a1293b75-945a-4a8b-9e75-47fe77b2ac08", "name": "load_p1rlv788_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9f470d9-6ead-4413-ad8a-7ccc69ae9237"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4b9db413-91c2-4b76-9e16-748421872017"}}}}, {"uuid": "2995fa38-c796-407f-b921-aa40a63a21a5", "name": "da1c4ecf-5cec-4267-81c4-b45fc78f34d1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1146755706450526, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5956233891083068, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3f242781-55ca-45dc-80f0-7e15ad23a6ca", "name": "63e7d2cd-0504-4847-8012-5e2723d55f6a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2995fa38-c796-407f-b921-aa40a63a21a5"}}}]}, {"uuid": "07f0059d-15e9-4a01-9e08-bee0656f3c1b", "name": "load_p1rlv789_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9ce2439-fcc7-4965-81ee-f875db83b003"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3f242781-55ca-45dc-80f0-7e15ad23a6ca"}}}}, {"uuid": "cd40daea-6940-49fa-b2d8-685091be24c7", "name": "7cc7695b-9b9e-42fc-b8fd-de7fda9a3f7f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1146755706450526, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5956233891083068, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "abd3d946-ff0d-4c90-b67c-3a474857170f", "name": "cfc12075-8e2f-4e2d-9c71-5c99072bdd41", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cd40daea-6940-49fa-b2d8-685091be24c7"}}}]}, {"uuid": "8e04a276-1831-4a10-89ac-8e0cc810ac43", "name": "load_p1rlv789_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9ce2439-fcc7-4965-81ee-f875db83b003"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "abd3d946-ff0d-4c90-b67c-3a474857170f"}}}}, {"uuid": "67358195-51ef-441c-a590-de52ce404ae5", "name": "313602cc-e67f-4578-abdd-9f8eb3be2c03_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.507865878359724, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5977385470921427, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a32bf0e6-797a-4730-a940-ac2793a72dda", "name": "390e6fa0-70fa-4622-953b-612514c57b46", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "67358195-51ef-441c-a590-de52ce404ae5"}}}]}, {"uuid": "32d4ada8-ea2a-4266-9e2e-0aee1c3746c3", "name": "load_p1rlv790_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf42fa7f-370e-400e-8f6d-76eb8c70ecb9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a32bf0e6-797a-4730-a940-ac2793a72dda"}}}}, {"uuid": "059c12b8-7a4d-474e-b868-f82f1115f672", "name": "d3aa0c32-6da1-4087-b743-172cc3bf2a07_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.507865878359724, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5977385470921427, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bc4817fe-0da3-43f5-ad60-a477d7c8576b", "name": "2a94ff1c-f549-461e-8968-54329535288e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "059c12b8-7a4d-474e-b868-f82f1115f672"}}}]}, {"uuid": "cd07f9ea-7435-4b93-8fcc-a44d99da4aae", "name": "load_p1rlv790_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf42fa7f-370e-400e-8f6d-76eb8c70ecb9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bc4817fe-0da3-43f5-ad60-a477d7c8576b"}}}}, {"uuid": "f2079efb-f07c-41bc-94c2-584ae629605d", "name": "86210398-a9a8-4879-9e3c-b7e182dc94e5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.8801930784369265, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0115137645096066, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "58867ff1-aac8-41f5-a8f6-037f853e3cd6", "name": "72ae5231-2aed-4bdb-b71a-f9c042ea9b3f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f2079efb-f07c-41bc-94c2-584ae629605d"}}}]}, {"uuid": "6d6e5bd0-4069-4b2b-8a3b-a4b8156b0b6b", "name": "load_p1rlv791_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fe9bb3f-e3c1-4b59-b39f-f62271a55bdd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "58867ff1-aac8-41f5-a8f6-037f853e3cd6"}}}}, {"uuid": "cc6c614d-1f66-4f40-a958-de8b63523d00", "name": "1d8a2af4-40d4-47c0-a99f-71754c62732e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.8801930784369265, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0115137645096066, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d576a3e9-8707-405e-ad02-8b47148a6b96", "name": "458448a9-d21f-4598-ba66-2148ed15878b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cc6c614d-1f66-4f40-a958-de8b63523d00"}}}]}, {"uuid": "1fb64f7e-30c1-4b55-b646-32d6d63c9137", "name": "load_p1rlv791_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fe9bb3f-e3c1-4b59-b39f-f62271a55bdd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d576a3e9-8707-405e-ad02-8b47148a6b96"}}}}, {"uuid": "c8ca456b-103e-40a8-826f-9658b81c0c8c", "name": "a58593df-f306-44d4-956d-19bd50b79f7a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7628538083737542, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7287957147649712, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d505cfe9-c55f-44e1-a8d2-8b1fffbb1241", "name": "106e892e-878c-4a5c-ad20-d2887fbfb751", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c8ca456b-103e-40a8-826f-9658b81c0c8c"}}}]}, {"uuid": "31f2fd4f-1cac-4765-a201-816b91860a72", "name": "load_p1rlv792_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f806232e-0a52-46d5-80f7-7ea3a914137a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d505cfe9-c55f-44e1-a8d2-8b1fffbb1241"}}}}, {"uuid": "92485c07-f490-4bbc-a625-20051376dba7", "name": "e18075de-75e7-40cb-a8c4-29a5ff6f87ed_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7628538083737542, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7287957147649712, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "967be153-6d35-4c97-a427-d053a9ef357e", "name": "a2138130-423b-4e33-8b77-76ebb1b6dafa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "92485c07-f490-4bbc-a625-20051376dba7"}}}]}, {"uuid": "b24d80d1-0fb7-41c9-98d8-b2e48b6d99c1", "name": "load_p1rlv792_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f806232e-0a52-46d5-80f7-7ea3a914137a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "967be153-6d35-4c97-a427-d053a9ef357e"}}}}, {"uuid": "4f125316-f1dc-4264-a48a-3eb422837b73", "name": "ca0b469e-5b49-4e05-a6e6-f1796455c4fe_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3510125413548424, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5621017434083633, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7f3c53b7-1c9e-4f38-aa93-41bfe2410c5f", "name": "096b7ce4-2993-4f74-a691-64c767bd5807", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4f125316-f1dc-4264-a48a-3eb422837b73"}}}]}, {"uuid": "6624cffa-97dd-4f2f-a93c-6283af6764c1", "name": "load_p1rlv793_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e8c4bc9-0688-43e6-93a8-9664c9b618b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7f3c53b7-1c9e-4f38-aa93-41bfe2410c5f"}}}}, {"uuid": "48ff241c-9d0d-4e99-9630-c7c010dcbfc4", "name": "458cf665-3d81-4248-8d50-75e991f6dd7a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3510125413548424, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5621017434083633, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "25886f1d-2b99-4844-9818-12e1072e4078", "name": "fdb32a95-93af-4633-951a-7ce676661d31", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "48ff241c-9d0d-4e99-9630-c7c010dcbfc4"}}}]}, {"uuid": "ba48e384-469b-4bfe-b930-408e95243541", "name": "load_p1rlv793_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e8c4bc9-0688-43e6-93a8-9664c9b618b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "25886f1d-2b99-4844-9818-12e1072e4078"}}}}, {"uuid": "a433be39-5d29-46d5-af99-b5433f4eb28e", "name": "4cbdee84-762e-4ffe-b5ca-739d59c579f6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8660061383019082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.44544683702444765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "563fee7b-f9a7-4c21-ad96-84ff8c32ca24", "name": "794f19a1-12cb-4fd3-8a38-28db448457eb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a433be39-5d29-46d5-af99-b5433f4eb28e"}}}]}, {"uuid": "d4736669-6c0f-458e-b2bf-564059c09a88", "name": "load_p1rlv794_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eecc456-41af-4242-ab30-d8ca45d55a2c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "563fee7b-f9a7-4c21-ad96-84ff8c32ca24"}}}}, {"uuid": "ed90e9c2-75fc-4ccb-a6ea-9678e556a42b", "name": "fa8d3016-4cf5-4d13-b2fa-6e4f6cd801c1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8660061383019082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.44544683702444765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "46083046-bc68-4957-9762-f7c32f3ed87a", "name": "73f557bd-a82b-4859-a8a7-96565bb7ca35", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ed90e9c2-75fc-4ccb-a6ea-9678e556a42b"}}}]}, {"uuid": "77460682-1d6c-4df8-8eae-c8393e31aca8", "name": "load_p1rlv794_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eecc456-41af-4242-ab30-d8ca45d55a2c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "46083046-bc68-4957-9762-f7c32f3ed87a"}}}}, {"uuid": "6c710181-e2b6-4826-b884-cb0d10b219a0", "name": "253e183e-ba89-4e13-b8ad-ff127796e36c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.083951745833768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9853982282300497, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0653bc01-11d5-4990-9a66-94333ae0f39e", "name": "94bdb433-37d8-4f57-8525-84aec78cf6a4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c710181-e2b6-4826-b884-cb0d10b219a0"}}}]}, {"uuid": "1842e1ea-1f3a-44f6-86da-050c29265f33", "name": "load_p1rlv795_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb137176-0642-4d87-ae40-1b7b0e1cb214"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0653bc01-11d5-4990-9a66-94333ae0f39e"}}}}, {"uuid": "c9e78314-1f2b-48b3-86db-2504aa47b9d1", "name": "517dfb60-554d-4efb-95e7-209b287750bd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.083951745833768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9853982282300497, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e17db933-2332-4184-acb3-983d9976b88d", "name": "00024c62-6f74-4838-ac6f-c4e4ab032493", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9e78314-1f2b-48b3-86db-2504aa47b9d1"}}}]}, {"uuid": "11d0c30a-c620-42e1-9c1b-108bbaf9c2c8", "name": "load_p1rlv795_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb137176-0642-4d87-ae40-1b7b0e1cb214"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e17db933-2332-4184-acb3-983d9976b88d"}}}}, {"uuid": "dd4817ff-9567-48fc-a612-d4f252b795a5", "name": "34accbdf-746d-4883-9760-04afcf68e08e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0085854932437286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7150296414254909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "755376c1-8d90-4413-bb42-962c9347ffbf", "name": "29e47ff3-8353-40ff-8f54-01b484e9267c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dd4817ff-9567-48fc-a612-d4f252b795a5"}}}]}, {"uuid": "32b85a02-d101-4205-852e-f12e6d5349e0", "name": "load_p1rlv796_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59662cef-c126-4188-ad86-844f6cabaf34"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "755376c1-8d90-4413-bb42-962c9347ffbf"}}}}, {"uuid": "d09ed02f-0edd-4bc2-83fd-f36c855f6ec6", "name": "764f4a73-d05f-4d60-9bd3-bf7d1e36c0e1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0085854932437286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7150296414254909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "79449805-4e72-494a-87d2-57dad2817656", "name": "7bba4b8f-3ec6-4e8c-bf7d-471827c3cd54", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d09ed02f-0edd-4bc2-83fd-f36c855f6ec6"}}}]}, {"uuid": "44f27ce1-c9f1-4f28-a727-53e65be90070", "name": "load_p1rlv796_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59662cef-c126-4188-ad86-844f6cabaf34"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "79449805-4e72-494a-87d2-57dad2817656"}}}}, {"uuid": "b5f8d76c-a753-4d81-b731-5d3dff6e99d9", "name": "5a907586-3b6b-44f9-b487-1a3d596627ed_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.127438645009231, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8176304041402817, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c6a0a7a4-5fe0-4b41-8a8f-0a33c6123d0b", "name": "0926481c-375c-45c6-8bc9-796e6fccc09b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5f8d76c-a753-4d81-b731-5d3dff6e99d9"}}}]}, {"uuid": "a12f00cb-3c93-410c-a003-2b94e48aeec0", "name": "load_p1rlv797_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b1c34f1-2613-46aa-9a9f-686ee518e559"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c6a0a7a4-5fe0-4b41-8a8f-0a33c6123d0b"}}}}, {"uuid": "1518672b-3dd9-496d-8565-f93c0eed2369", "name": "7a4a591f-f997-471d-ab7e-16e7d400ace9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.127438645009231, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8176304041402817, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a47ee959-4933-4ad4-ae2c-7fe6b20ce82a", "name": "ac50e232-492f-46d1-8e34-e3bfc191470b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1518672b-3dd9-496d-8565-f93c0eed2369"}}}]}, {"uuid": "cf856919-7fc5-4818-8d6f-28087f021ebe", "name": "load_p1rlv797_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b1c34f1-2613-46aa-9a9f-686ee518e559"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a47ee959-4933-4ad4-ae2c-7fe6b20ce82a"}}}}, {"uuid": "d4417dbc-b4db-49bd-8feb-627965850552", "name": "7bd8265e-cdf2-4bc7-ad3d-09ac6aeb4d16_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.839033632547656, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.36892018645953045, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b7b0c9cb-b446-4f62-9873-638405bd7a3d", "name": "437537d8-a0dd-416a-a449-1a6a634f5d26", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d4417dbc-b4db-49bd-8feb-627965850552"}}}]}, {"uuid": "1a71adb8-ddc6-4746-9b53-90cfd4bf60ac", "name": "load_p1rlv798_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c30005d7-7e42-4a08-8935-0c7227fba4a6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b7b0c9cb-b446-4f62-9873-638405bd7a3d"}}}}, {"uuid": "86ef5b5f-77f6-450d-b85a-2d57d870054c", "name": "9345b937-0745-4a39-8b8e-cca85f4d14b4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.839033632547656, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.36892018645953045, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6df4ee25-a6ea-4b19-9eeb-8e5124bd1fdf", "name": "335aa7fd-9a7a-43c0-94a5-69d03ad5089a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "86ef5b5f-77f6-450d-b85a-2d57d870054c"}}}]}, {"uuid": "475ac95f-30e7-4ab2-b9f6-97693f55195d", "name": "load_p1rlv798_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c30005d7-7e42-4a08-8935-0c7227fba4a6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6df4ee25-a6ea-4b19-9eeb-8e5124bd1fdf"}}}}, {"uuid": "27620e64-36f4-40ba-978e-de18bc4e532b", "name": "62e4942b-d3a0-498c-948a-12e3b7f8dcad_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.046232297850773, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7285366000251032, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cac38115-fa29-4a33-b1ef-955dc8b3b3f4", "name": "4ddf73be-47d5-41d8-a0af-f1089e7f3fa8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "27620e64-36f4-40ba-978e-de18bc4e532b"}}}]}, {"uuid": "ed1b18d9-960b-4b41-9994-578e21b4add9", "name": "load_p1rlv799_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f706d9d-0cb1-453b-9ca5-377f7d766099"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cac38115-fa29-4a33-b1ef-955dc8b3b3f4"}}}}, {"uuid": "58b99372-8eba-4bfd-9257-73cafdb761d2", "name": "fe6be4cf-f2be-4f13-9b0d-2925c42f365e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.046232297850773, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7285366000251032, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "09e0bc18-e092-4871-9310-559dd3979e4f", "name": "afbdf141-92fc-44c6-8829-317e342e3cd2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58b99372-8eba-4bfd-9257-73cafdb761d2"}}}]}, {"uuid": "191e9bea-c480-48d9-95bb-178ae994ab05", "name": "load_p1rlv799_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f706d9d-0cb1-453b-9ca5-377f7d766099"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "09e0bc18-e092-4871-9310-559dd3979e4f"}}}}, {"uuid": "cdc15692-4ad5-4014-a5ed-35a494709340", "name": "9a65e01b-2a25-4c33-9767-a0c5f3a169d9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2795803428770153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1698974287191981, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "30c757e1-f5f5-478f-8cfe-1b6a8ad5bf87", "name": "238dc65a-8496-493e-ba24-9caa91cdd716", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cdc15692-4ad5-4014-a5ed-35a494709340"}}}]}, {"uuid": "e20c0dc1-5195-4f50-8e05-0dd4080c5b83", "name": "load_p1rlv800_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3126c61-9602-45cf-8d57-27d26c14ca7e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "30c757e1-f5f5-478f-8cfe-1b6a8ad5bf87"}}}}, {"uuid": "f8b39291-b936-4c7e-a0c8-c43db1817944", "name": "7f80a2f3-4e2c-4048-bf17-54d0f67df2f1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2795803428770153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1698974287191981, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d540a418-a6ec-4518-bc0e-61fc04cc42b2", "name": "ae58a800-02f8-4f30-a632-f7d4f32f9846", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8b39291-b936-4c7e-a0c8-c43db1817944"}}}]}, {"uuid": "4cbeba7c-b5dd-4e8f-bbee-7081b2b5b5f8", "name": "load_p1rlv800_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3126c61-9602-45cf-8d57-27d26c14ca7e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d540a418-a6ec-4518-bc0e-61fc04cc42b2"}}}}, {"uuid": "e25eb9c7-da87-4f68-9322-79e1381c82c9", "name": "4a7ac419-9d21-4faa-bf7a-df40e3c17cc5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2142575595505583, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8511261488468437, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c1b13cd-f503-4295-800a-46586da7cbaa", "name": "d29ba3ab-cbae-4437-9a3a-154ba2c85de5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e25eb9c7-da87-4f68-9322-79e1381c82c9"}}}]}, {"uuid": "d1a79f47-823e-489e-9102-bfd8661a0698", "name": "load_p1rlv801_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ecc45b2-1fbe-4a31-995f-e2f8fffe61a7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c1b13cd-f503-4295-800a-46586da7cbaa"}}}}, {"uuid": "7c34c779-171c-4a0e-9e87-e7988cb61122", "name": "0ab8dd7e-65d8-4fd1-a56e-86ebbc67d9a5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2142575595505583, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8511261488468437, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "620ff808-897f-4bb3-8cf6-1a3e02e6a00d", "name": "7b4b2a27-3f17-4c47-bda6-8f9c0aaf4e06", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7c34c779-171c-4a0e-9e87-e7988cb61122"}}}]}, {"uuid": "04816d23-d595-4b23-9d7c-736dd614d965", "name": "load_p1rlv801_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ecc45b2-1fbe-4a31-995f-e2f8fffe61a7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "620ff808-897f-4bb3-8cf6-1a3e02e6a00d"}}}}, {"uuid": "6a83fbb7-afe1-47d8-b2da-92214e07d67a", "name": "b078b8bf-7601-453e-a44d-d6208a434655_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.621947646480353, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0332384495271123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9b9deaaf-bc34-40fb-82b1-6502cd1d6393", "name": "c5ab4f42-4ac5-43ff-9588-89aa16263451", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6a83fbb7-afe1-47d8-b2da-92214e07d67a"}}}]}, {"uuid": "226177fd-fc5f-43d1-92ad-aa76bcd7f486", "name": "load_p1rlv802_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2436086-d5c4-4b70-a402-e7d1b6f5b77e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9b9deaaf-bc34-40fb-82b1-6502cd1d6393"}}}}, {"uuid": "edadc232-577f-4196-9c92-4982f9b32db8", "name": "a8b3a10b-50ff-4be6-b58b-612ba1efca1d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.621947646480353, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0332384495271123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f8c9d64d-a92c-4fab-a690-34c10f1e6876", "name": "de4abd99-b477-48f0-854d-a5de0fbab94f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "edadc232-577f-4196-9c92-4982f9b32db8"}}}]}, {"uuid": "5513bc2f-7647-49ad-acf0-cad7dc4344b8", "name": "load_p1rlv802_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2436086-d5c4-4b70-a402-e7d1b6f5b77e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f8c9d64d-a92c-4fab-a690-34c10f1e6876"}}}}, {"uuid": "4a6e72dc-0fd5-4a6d-a760-6bca463c7958", "name": "2d097c22-693f-465b-ab51-97c98658be1b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.991433457795887, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5982568468826307, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "93e40e12-3a0b-4142-b1b8-2798f6023a59", "name": "6324b962-f7ac-4458-92f4-14eff840fa9d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4a6e72dc-0fd5-4a6d-a760-6bca463c7958"}}}]}, {"uuid": "1a518b9a-23c3-404f-8aa6-9fef87d86748", "name": "load_p1rlv803_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "018c978c-5673-4090-9792-b75ee161f6d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "93e40e12-3a0b-4142-b1b8-2798f6023a59"}}}}, {"uuid": "f1d9e12c-3c70-4e12-b43a-42993ad845bf", "name": "4584a0d0-a1a7-4113-89fd-c3670eef0f71_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.991433457795887, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5982568468826307, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "13304da8-6eed-4a95-be24-9c06f1773a88", "name": "40305169-1355-4f4b-b05e-9a9f83d02553", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f1d9e12c-3c70-4e12-b43a-42993ad845bf"}}}]}, {"uuid": "4119dd23-3bfa-4b70-a7b2-b5cfe56c9ba1", "name": "load_p1rlv803_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "018c978c-5673-4090-9792-b75ee161f6d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "13304da8-6eed-4a95-be24-9c06f1773a88"}}}}, {"uuid": "c1fb01ee-0a2a-408e-b93d-63b1e0ae075c", "name": "0453fe34-a68d-4aa6-b3f3-f8be97681717_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.292799122473319, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5385753507809203, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f3134e33-7b18-431b-b107-337c262ecfb1", "name": "c1f9910b-dff3-4cd6-a77d-a29738ad9094", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c1fb01ee-0a2a-408e-b93d-63b1e0ae075c"}}}]}, {"uuid": "22899ffe-ad39-4be8-963a-658a3c025e92", "name": "load_p1rlv804_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a11ba246-99d9-4cf5-a557-bec53c75e6fb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f3134e33-7b18-431b-b107-337c262ecfb1"}}}}, {"uuid": "0577474f-713e-42a1-8360-6b5315691b7b", "name": "841c637a-f73e-4be3-851d-44ee71e33f7e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.292799122473319, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5385753507809203, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a70eccf7-9561-45ff-8e98-edcb8caddc1c", "name": "0bfa7b8d-3957-40b6-a517-47cc3bccd8c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0577474f-713e-42a1-8360-6b5315691b7b"}}}]}, {"uuid": "0d0dfa2c-b47a-4f09-894d-383a0abaa69f", "name": "load_p1rlv804_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a11ba246-99d9-4cf5-a557-bec53c75e6fb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a70eccf7-9561-45ff-8e98-edcb8caddc1c"}}}}, {"uuid": "cb90b3f2-2054-4a12-9bc1-174278764562", "name": "482d07e2-73a2-47d8-8077-9f733d11d325_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.987999469244499, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42543082019456707, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "02b2e4ae-c602-4a01-8dd0-8d4927f5c6bc", "name": "5f096ec6-979d-4f96-b37f-e4c023012d2c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cb90b3f2-2054-4a12-9bc1-174278764562"}}}]}, {"uuid": "94306602-9d91-4717-ac32-7601a7eec3a6", "name": "load_p1rlv805_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0475b34e-14ab-48e4-9df7-7444de1cde7d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "02b2e4ae-c602-4a01-8dd0-8d4927f5c6bc"}}}}, {"uuid": "e6faa0df-44b4-4ab4-918b-1ac3460b4f1a", "name": "354eb4e2-ce6d-4c16-bebc-38a7c83ac69b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.987999469244499, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42543082019456707, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9d416776-a183-456b-b3f3-1e4c13d23875", "name": "0e5a2587-eec9-45b4-b4aa-e20da2ae3c80", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e6faa0df-44b4-4ab4-918b-1ac3460b4f1a"}}}]}, {"uuid": "7f0817b8-99e8-4e61-bae4-015564a8978b", "name": "load_p1rlv805_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0475b34e-14ab-48e4-9df7-7444de1cde7d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9d416776-a183-456b-b3f3-1e4c13d23875"}}}}, {"uuid": "a1ae1f2a-6525-4488-8ddb-939e2c0a6bd9", "name": "86da67d3-dce4-40fa-924a-bfd2f591e54f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4950137537296666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31506625700854357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1176d2d0-4537-427d-99f7-59a44be17d94", "name": "db2b683a-b000-4b9c-9f6c-6fa3b027495e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a1ae1f2a-6525-4488-8ddb-939e2c0a6bd9"}}}]}, {"uuid": "09209c20-e17c-4675-b697-6afbacbb6e84", "name": "load_p1rlv806_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d9f269a-e476-4b82-a258-479d812d008d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1176d2d0-4537-427d-99f7-59a44be17d94"}}}}, {"uuid": "449e2e01-3cda-4040-bc51-39368c4a4046", "name": "a35047b0-fa29-4029-8d3a-5db7b73ea064_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4950137537296666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31506625700854357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7b3eeaba-f61b-4142-ae6e-89b24fce4547", "name": "a1528b96-8255-40de-8286-0171a4fe4581", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "449e2e01-3cda-4040-bc51-39368c4a4046"}}}]}, {"uuid": "dcc8b148-384f-4fa3-812b-52a49190219f", "name": "load_p1rlv806_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d9f269a-e476-4b82-a258-479d812d008d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7b3eeaba-f61b-4142-ae6e-89b24fce4547"}}}}, {"uuid": "71b51c74-d6e6-4e69-ac4a-677a95d0675a", "name": "21e2b630-e823-42b6-bf6d-863135e0c886_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.107858967059457, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3651352875232526, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ed616a72-ab12-4ce3-bace-d557ffc4cf34", "name": "e5242d07-16b8-465d-a1e4-90a257ee9cd7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "71b51c74-d6e6-4e69-ac4a-677a95d0675a"}}}]}, {"uuid": "fa476b20-630e-4d59-9f0f-a8d14a86554f", "name": "load_p1rlv807_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa259be8-8a61-461a-9e58-d4aaf1ce82db"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ed616a72-ab12-4ce3-bace-d557ffc4cf34"}}}}, {"uuid": "72f20477-33d2-4d5f-98ed-d5010b124c54", "name": "6ffe1ec2-6fcf-4f97-87fc-26865a0b7b7e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.107858967059457, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3651352875232526, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8b348d9f-802d-4db1-af83-c40d16a11169", "name": "54895934-cecc-4d92-8979-d00e62ba2e97", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72f20477-33d2-4d5f-98ed-d5010b124c54"}}}]}, {"uuid": "1d5c684d-9e7e-4e27-9f6c-89984f50cbb4", "name": "load_p1rlv807_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa259be8-8a61-461a-9e58-d4aaf1ce82db"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8b348d9f-802d-4db1-af83-c40d16a11169"}}}}, {"uuid": "10863d87-e2c5-4f8a-95c4-f779a208f6d2", "name": "cd9fef9d-a919-4b00-921e-8c2298a2343b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.847886228314274, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0445060168814917, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9d60dc14-18d9-41dc-bac8-1dc54d1cdd83", "name": "c37b3af4-0023-4302-82e0-be5197005d2b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "10863d87-e2c5-4f8a-95c4-f779a208f6d2"}}}]}, {"uuid": "c3bf69ee-2387-463a-a620-8889c6e696ed", "name": "load_p1rlv808_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dcb86a4-e6d7-48b4-b5c2-904635de271b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9d60dc14-18d9-41dc-bac8-1dc54d1cdd83"}}}}, {"uuid": "0ff26188-9f62-4401-8eaf-cfb058a40d76", "name": "f8daf638-4988-4e32-a558-2f17ccc10c4c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.847886228314274, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0445060168814917, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1108b691-7c26-477f-9c44-852d57e6c28a", "name": "36964797-4a01-4e6b-8193-17fdf9418144", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0ff26188-9f62-4401-8eaf-cfb058a40d76"}}}]}, {"uuid": "275d8b4b-180a-4ba5-8afe-6c5a984f910e", "name": "load_p1rlv808_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dcb86a4-e6d7-48b4-b5c2-904635de271b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1108b691-7c26-477f-9c44-852d57e6c28a"}}}}, {"uuid": "b90c43fd-9545-43d5-aa26-284f131d6951", "name": "fadbe899-067e-4fda-bd48-0fcb3363d23c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.739385174805638, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.976019322648958, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "861fff20-0acd-41c1-a98a-ffd197592db2", "name": "5c1659e7-028e-4567-bd50-da2566583a1d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b90c43fd-9545-43d5-aa26-284f131d6951"}}}]}, {"uuid": "9b75a966-d766-4da4-b3a9-99bb64317eaa", "name": "load_p1rlv809_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e0f8ee8-795f-4bea-bf7a-e2c477eefb89"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "861fff20-0acd-41c1-a98a-ffd197592db2"}}}}, {"uuid": "67a83380-fd27-4dbf-9f41-5025a8c30e9d", "name": "c4165a6b-63a1-4dbf-b432-ba5eb71b30bd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.739385174805638, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.976019322648958, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a2dcb90f-3ae2-411f-9321-5e5cf47b9fe9", "name": "1d108e2d-210d-4c1b-8fea-98eaaaac21cd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "67a83380-fd27-4dbf-9f41-5025a8c30e9d"}}}]}, {"uuid": "3f913e9e-d1c1-4fff-b236-303d44b401dc", "name": "load_p1rlv809_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e0f8ee8-795f-4bea-bf7a-e2c477eefb89"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a2dcb90f-3ae2-411f-9321-5e5cf47b9fe9"}}}}, {"uuid": "411f0651-0785-4e4f-99cc-b3715b12ea36", "name": "c1c6ca54-dd95-46f0-b798-4c803fd7167e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8309189378455104, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6069744647018672, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "03f741ce-96ad-4a1b-8277-ce411a51c68b", "name": "c368e4cc-7046-4395-bb00-5dce2f763b1b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "411f0651-0785-4e4f-99cc-b3715b12ea36"}}}]}, {"uuid": "28a09673-3ba1-4c43-9c43-3b7aa624b2a8", "name": "load_p1rlv810_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb4a881f-684d-48e4-a6f0-5832f73d140a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "03f741ce-96ad-4a1b-8277-ce411a51c68b"}}}}, {"uuid": "7901af69-6f57-4a73-b623-9e63c9300013", "name": "d8d7a554-5a06-4356-8cd0-15d4eb3e4a88_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8309189378455104, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6069744647018672, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f103a8ea-9301-4fda-81c7-a2f0b00444ea", "name": "0c4a7bcb-a22e-4fa1-abc1-71508477e6a6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7901af69-6f57-4a73-b623-9e63c9300013"}}}]}, {"uuid": "9704a4db-8a6e-4150-a7a1-4434d753063b", "name": "load_p1rlv810_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb4a881f-684d-48e4-a6f0-5832f73d140a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f103a8ea-9301-4fda-81c7-a2f0b00444ea"}}}}, {"uuid": "58540381-46f0-4842-b1f7-6f12c33c1aaa", "name": "3a3f1738-9558-40b1-803f-36ade87a88d0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7362273540893955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24527287728713068, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "535428b8-7298-4e27-8f95-a29be5db7f75", "name": "69a403d1-f846-495a-8ee7-1090e160611e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58540381-46f0-4842-b1f7-6f12c33c1aaa"}}}]}, {"uuid": "6aa9335f-11aa-4850-b488-a3b57ff0810c", "name": "load_p1rlv811_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "052949b1-9e85-4be7-993c-9e97efda3657"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "535428b8-7298-4e27-8f95-a29be5db7f75"}}}}, {"uuid": "d8097276-eed1-4787-91df-157c2fe5246c", "name": "74da4ae4-969e-4389-ba97-5e937297c4b4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7362273540893955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24527287728713068, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ff4d4f14-c6e8-4311-97fb-9a84145923c4", "name": "590a0c92-c812-41de-ae77-37676b1dd971", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d8097276-eed1-4787-91df-157c2fe5246c"}}}]}, {"uuid": "5e75c977-5c96-49b7-b33e-bd0dddd5db3b", "name": "load_p1rlv811_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "052949b1-9e85-4be7-993c-9e97efda3657"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ff4d4f14-c6e8-4311-97fb-9a84145923c4"}}}}, {"uuid": "d9c9c1f7-9a73-43ad-89bd-318929ad3ab7", "name": "1069ede5-9826-4402-8e4a-ceb7acb95f5b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0599252267318962, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3748861224482183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50152347-5bdb-49be-b9e0-01759af6ed74", "name": "b2bf3543-58fa-4099-9477-15cd1ff1a0b7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d9c9c1f7-9a73-43ad-89bd-318929ad3ab7"}}}]}, {"uuid": "82dea5fe-cd3a-42bd-a5f2-9d088a939774", "name": "load_p1rlv812_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26fea867-af5f-4213-b9c3-487975d1285e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50152347-5bdb-49be-b9e0-01759af6ed74"}}}}, {"uuid": "4c83845b-74b7-4ab5-8191-373fe40720fd", "name": "6faaffee-3331-4355-aa1e-1c718446170d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0599252267318962, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3748861224482183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "667a104b-536d-42cb-816c-35a837cf2f9c", "name": "f4293f81-a29c-4b0d-9b5e-0819f2ea6af3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4c83845b-74b7-4ab5-8191-373fe40720fd"}}}]}, {"uuid": "d01e44be-07f1-4f33-9f4d-b8b64c9f8c4e", "name": "load_p1rlv812_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26fea867-af5f-4213-b9c3-487975d1285e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "667a104b-536d-42cb-816c-35a837cf2f9c"}}}}, {"uuid": "74c8e1af-8f80-4b63-8126-b89b014016fe", "name": "80123125-5b25-452c-aa68-8772e6db11d1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7457942211533133, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8784341351558463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bc2a2099-56de-42de-8494-e78cc7abf913", "name": "3f111631-2636-4a5d-95d6-45a74a6c73c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "74c8e1af-8f80-4b63-8126-b89b014016fe"}}}]}, {"uuid": "c527ba67-9ea4-4e8e-b824-7e21912984ae", "name": "load_p1rlv813_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10d44b60-55c0-4d78-abbb-52c8cd67134b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bc2a2099-56de-42de-8494-e78cc7abf913"}}}}, {"uuid": "76e54313-3a38-4657-9e11-ca3a54a65c86", "name": "6e582f0d-b6ca-41f6-9d92-3c66c8efced8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7457942211533133, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8784341351558463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7bd4b1d3-e002-4251-8d5f-b1ab9b73ea9f", "name": "2547f8ca-a395-4e67-854e-078bfad68612", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "76e54313-3a38-4657-9e11-ca3a54a65c86"}}}]}, {"uuid": "020e8cbe-3954-4821-8e3a-e5aeec53bd36", "name": "load_p1rlv813_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10d44b60-55c0-4d78-abbb-52c8cd67134b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7bd4b1d3-e002-4251-8d5f-b1ab9b73ea9f"}}}}, {"uuid": "58ad71a3-0c2d-44a6-b0ee-7505907d451c", "name": "852e816c-ea4f-467b-8a6e-39eccd098c5c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.559104904760759, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9054328372998879, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "67877123-5ca0-4a19-a3b5-dd96d917765e", "name": "4a6c75be-9ab3-4470-b580-fb976de83b81", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58ad71a3-0c2d-44a6-b0ee-7505907d451c"}}}]}, {"uuid": "35d25ebf-a90f-48cc-8646-7ffa7626e103", "name": "load_p1rlv814_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b8065f3-8286-4f99-aa56-b9b631a2f838"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "67877123-5ca0-4a19-a3b5-dd96d917765e"}}}}, {"uuid": "bc3882ff-f092-48c8-bfeb-1052dde4966e", "name": "12d12581-ea08-41f0-971d-8554dadfd08d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.559104904760759, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9054328372998879, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0280bd4b-f7b8-455d-b020-1545d7160332", "name": "a5919842-32a2-4d76-9d02-bdb0b1001d6f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bc3882ff-f092-48c8-bfeb-1052dde4966e"}}}]}, {"uuid": "64cf4715-7576-460b-a418-5f1026488522", "name": "load_p1rlv814_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b8065f3-8286-4f99-aa56-b9b631a2f838"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0280bd4b-f7b8-455d-b020-1545d7160332"}}}}, {"uuid": "16ea51e7-cc44-48d1-ae9b-8225235d9388", "name": "0614d656-6794-4b42-b0fc-736838c79079_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5424601784243566, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31457775613808403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0bba08a5-c480-4c68-91bd-ee13541689d4", "name": "d5448476-a6b8-4f95-9116-644f14416659", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "16ea51e7-cc44-48d1-ae9b-8225235d9388"}}}]}, {"uuid": "f74b3e0a-a07f-41e6-aebd-8ab1b254bb5b", "name": "load_p1rlv815_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a134556-828b-4e0c-8773-2f207802e33a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0bba08a5-c480-4c68-91bd-ee13541689d4"}}}}, {"uuid": "ad0b2281-280e-4076-8064-667a6d21ed4f", "name": "de19320e-a7de-4eb0-99aa-bfe8567f4a97_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5424601784243566, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31457775613808403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f2d71091-b353-43e0-8aa5-403a8f7cb0b4", "name": "4275bf63-4eb4-4851-96cb-99b331938601", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ad0b2281-280e-4076-8064-667a6d21ed4f"}}}]}, {"uuid": "6e68ad30-1e54-48c4-91e8-bf82491286e3", "name": "load_p1rlv815_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a134556-828b-4e0c-8773-2f207802e33a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f2d71091-b353-43e0-8aa5-403a8f7cb0b4"}}}}, {"uuid": "cc6a60b4-daec-4a6e-9d12-9ae8392dd142", "name": "63c541fe-b2e0-4195-add5-1638ee13af84_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.357764823379774, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7869023210214492, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b2886171-89c1-477c-83a0-d51f6cb7b994", "name": "3bf69e6f-2184-4351-891b-529fb58f8505", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cc6a60b4-daec-4a6e-9d12-9ae8392dd142"}}}]}, {"uuid": "1d166bab-8038-4240-bd6a-990676496f71", "name": "load_p1rlv816_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d6de7c2-fd2c-4071-8e90-1513f521cf87"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b2886171-89c1-477c-83a0-d51f6cb7b994"}}}}, {"uuid": "29adaec0-7aae-48a3-ab81-8e9adb2b7dd8", "name": "5b8fe093-71c0-4840-b92f-1c8335949f70_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.357764823379774, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7869023210214492, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "edc520af-667a-4ee9-b69c-602f2ee46cd9", "name": "57027629-6e91-4bed-bfee-cbdba2e2ee83", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "29adaec0-7aae-48a3-ab81-8e9adb2b7dd8"}}}]}, {"uuid": "f806dba9-9864-4a17-98e6-8c7e5e404f25", "name": "load_p1rlv816_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d6de7c2-fd2c-4071-8e90-1513f521cf87"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "edc520af-667a-4ee9-b69c-602f2ee46cd9"}}}}, {"uuid": "40ec427d-4957-4781-9f16-defc4fee8c6c", "name": "275b825d-0d85-47d5-80e1-e7f977a40dcb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1206689642843692, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34257205075767067, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f2e22e49-ad98-46fc-b3f6-b9815b9ab095", "name": "2c11f1b6-aa7c-40a6-b8b2-4e732406033b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "40ec427d-4957-4781-9f16-defc4fee8c6c"}}}]}, {"uuid": "75abaeea-16a0-4cc7-aec6-20c6a7b98961", "name": "load_p1rlv817_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11064c6f-3b7a-43b5-96ca-7ef96be3815e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f2e22e49-ad98-46fc-b3f6-b9815b9ab095"}}}}, {"uuid": "fdebb9b4-7dad-44e1-89fa-07845bbeafad", "name": "55c9250e-e64e-4954-8dbf-d93791a576e9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1206689642843692, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34257205075767067, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aae121fb-b12e-4312-b17b-f4a5fe5a6853", "name": "04384dfc-7214-4f2b-b449-060dc7a9c122", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fdebb9b4-7dad-44e1-89fa-07845bbeafad"}}}]}, {"uuid": "4c88d4b3-eeee-49c9-8200-c22d72a7e5c1", "name": "load_p1rlv817_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11064c6f-3b7a-43b5-96ca-7ef96be3815e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aae121fb-b12e-4312-b17b-f4a5fe5a6853"}}}}, {"uuid": "6cfcc2d1-35cc-4487-9fad-d776a52e44a4", "name": "546d460b-d910-4839-bab8-8fa5e7633188_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6669289783709, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.056901546523703654, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "03355bda-6ec3-41d7-bd7e-561878806338", "name": "7515a17d-db96-49cb-92eb-82f1034f0bfb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6cfcc2d1-35cc-4487-9fad-d776a52e44a4"}}}]}, {"uuid": "4dfc5955-660e-4595-a330-c040395a985c", "name": "load_p1rlv818_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd8c54fd-14d4-46fa-8bef-59c1097d5026"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "03355bda-6ec3-41d7-bd7e-561878806338"}}}}, {"uuid": "22c85500-9369-41ae-b2fd-df9cf5491168", "name": "c0d8a78f-2c84-47e6-a6f1-4539baf2a4c1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6669289783709, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.056901546523703654, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5ec7b202-9be4-4f06-90dd-c373fd66e271", "name": "18450587-18dd-495a-b503-26c3b7666697", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "22c85500-9369-41ae-b2fd-df9cf5491168"}}}]}, {"uuid": "5b11581f-6f3b-4e07-9631-582873c4ad2d", "name": "load_p1rlv818_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd8c54fd-14d4-46fa-8bef-59c1097d5026"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5ec7b202-9be4-4f06-90dd-c373fd66e271"}}}}, {"uuid": "29b9d5df-74fd-4d30-b8db-b1dc6baf59c5", "name": "700c68e8-f6bd-4e87-83ee-f0234d7744c5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.195601026095605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4379463760124337, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fe86b1ac-9749-4799-8245-57e5a38f23cb", "name": "01909453-2a47-428b-95f7-da66d28dbf70", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "29b9d5df-74fd-4d30-b8db-b1dc6baf59c5"}}}]}, {"uuid": "89ca12ad-7ca6-44eb-844b-402ac986d9ed", "name": "load_p1rlv819_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "def7e507-cb62-42f5-8451-b8a742ef4eb2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fe86b1ac-9749-4799-8245-57e5a38f23cb"}}}}, {"uuid": "2c2b7e63-bd59-4911-9dff-b60fb2ca9df0", "name": "9d2c38c2-cc88-474b-97b5-d32bf1220fb9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.195601026095605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4379463760124337, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9d7081f1-3610-4720-83ee-674d84afb519", "name": "deb735ed-88c7-483c-972c-ef5226dc0706", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2c2b7e63-bd59-4911-9dff-b60fb2ca9df0"}}}]}, {"uuid": "2360163a-c6ae-4a56-8b0f-268bf5d7f355", "name": "load_p1rlv819_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "def7e507-cb62-42f5-8451-b8a742ef4eb2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9d7081f1-3610-4720-83ee-674d84afb519"}}}}, {"uuid": "359e99f9-c749-4a63-9430-3d7d1687bf3a", "name": "dc8fcfe6-1b8d-4b27-9304-228eafb3bea7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.008167500419157, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.871384812064858, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "08081de5-092d-418d-8bf1-7a0776a98115", "name": "d6882342-2d99-4ee8-8620-51e18126df5d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "359e99f9-c749-4a63-9430-3d7d1687bf3a"}}}]}, {"uuid": "61583365-45ef-467f-bb32-f91025a8734e", "name": "load_p1rlv820_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41e1e576-4cc9-4fea-9d87-d436f000a675"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "08081de5-092d-418d-8bf1-7a0776a98115"}}}}, {"uuid": "2069248f-6ee1-48af-aef7-8148d4d28b60", "name": "f63716d2-ce08-4e7a-984e-76afa17927f9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.008167500419157, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.871384812064858, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2f52cef4-03b0-41b0-9cd8-e2ac77c6d1ca", "name": "f96170a8-efbe-4507-b6e8-ecf270701de9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2069248f-6ee1-48af-aef7-8148d4d28b60"}}}]}, {"uuid": "c8915dd6-3369-4fb4-acb5-5a4cd2081813", "name": "load_p1rlv820_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41e1e576-4cc9-4fea-9d87-d436f000a675"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2f52cef4-03b0-41b0-9cd8-e2ac77c6d1ca"}}}}, {"uuid": "924ed092-c747-45a6-83f1-d75008562baf", "name": "e48461e1-8dc1-479e-b509-d84abb5c5a92_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4363904318707768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7717292253609904, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3f825a39-24df-424e-9e0a-f0438f84d933", "name": "77fe357d-9cfb-4a07-82ac-389991596cde", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "924ed092-c747-45a6-83f1-d75008562baf"}}}]}, {"uuid": "516e8fd2-c4d4-49cd-b34a-7d09cbed8e5c", "name": "load_p1rlv821_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5578d8b4-7c1e-444f-8d27-8c9bf733f420"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3f825a39-24df-424e-9e0a-f0438f84d933"}}}}, {"uuid": "625516ba-61e6-4261-a54c-2f53d81cb1e4", "name": "43a1433d-0afd-42b1-988d-c93b6e2936e8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4363904318707768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7717292253609904, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "93d746a0-40ed-4eeb-a100-03d3b7d228dd", "name": "efadacd5-7018-4c44-8c40-90ffd6627a3e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "625516ba-61e6-4261-a54c-2f53d81cb1e4"}}}]}, {"uuid": "025864c7-1d2b-4f23-a563-57f117b54b95", "name": "load_p1rlv821_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5578d8b4-7c1e-444f-8d27-8c9bf733f420"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "93d746a0-40ed-4eeb-a100-03d3b7d228dd"}}}}, {"uuid": "9f385489-470c-4e4f-82ec-3e20b74fd3df", "name": "c396dca3-3bd5-4b66-8636-2b783f47eabc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3307696614484872, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.07740524652130432, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b108c76f-15e9-4990-af33-62b7addf308b", "name": "69701d81-85c2-43f5-be5e-bee3f7404249", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9f385489-470c-4e4f-82ec-3e20b74fd3df"}}}]}, {"uuid": "8382cc38-6044-45e3-9e0d-62ddfd873277", "name": "load_p1rlv822_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7ce197c-cee4-40df-b1d7-be13f1be8bb1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b108c76f-15e9-4990-af33-62b7addf308b"}}}}, {"uuid": "dd3e4e3a-3559-4027-afba-d627613059c6", "name": "21d52caf-ca54-492b-bc47-fa637a275d66_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3307696614484872, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.07740524652130432, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ba7bb2be-efad-4c03-8020-82c7b135863b", "name": "43163c38-efba-4c0e-9669-cef371ff9323", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dd3e4e3a-3559-4027-afba-d627613059c6"}}}]}, {"uuid": "1e56c001-43d9-4ef4-aa50-f82a1f42232d", "name": "load_p1rlv822_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7ce197c-cee4-40df-b1d7-be13f1be8bb1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ba7bb2be-efad-4c03-8020-82c7b135863b"}}}}, {"uuid": "43c1785d-9bed-4a42-877f-ad25a083d32e", "name": "de719e1f-e982-40a1-9d77-d4931c9ef1fe_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.396349422902612, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13402564403017767, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e5a93594-c464-46e5-94e3-ee0e9672a6f4", "name": "e81a1162-8c21-42ce-8159-51bf411564ae", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "43c1785d-9bed-4a42-877f-ad25a083d32e"}}}]}, {"uuid": "c6e5319e-9f6a-411c-af04-8f7bcbd5054c", "name": "load_p1rlv823_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81802469-7320-47e9-b826-fbb33bd371ab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e5a93594-c464-46e5-94e3-ee0e9672a6f4"}}}}, {"uuid": "732af354-3640-4143-8ab9-7f60cd75a7cb", "name": "67f449d4-29d0-41e9-926a-721a49b03abe_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.396349422902612, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13402564403017767, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e9e0b6ba-dd5c-4271-b788-e17debd0e9c1", "name": "99758b48-4b27-4629-9166-a329db484aa3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "732af354-3640-4143-8ab9-7f60cd75a7cb"}}}]}, {"uuid": "e28c0ad6-88fe-40ff-a288-8d5abdb44e54", "name": "load_p1rlv823_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81802469-7320-47e9-b826-fbb33bd371ab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e9e0b6ba-dd5c-4271-b788-e17debd0e9c1"}}}}, {"uuid": "ae0714a0-73be-4bae-8c83-bc9c9fa06ecf", "name": "6dcc93be-02a0-41ac-967f-e1079869c476_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2520868864654517, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.447133871274774, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7a24802e-526b-47a6-9ca6-2663b791840e", "name": "fd57d0f7-5105-4000-a96c-fa2643f11a48", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ae0714a0-73be-4bae-8c83-bc9c9fa06ecf"}}}]}, {"uuid": "7481a3f9-8384-48c9-9635-ee667876d70b", "name": "load_p1rlv824_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20ce76b6-9305-4525-b77e-b7300edc2c81"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7a24802e-526b-47a6-9ca6-2663b791840e"}}}}, {"uuid": "02a872db-8965-4030-be6c-e5eba07a0186", "name": "3bc89a2e-df99-411e-bfd7-7b60f6a0df53_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2520868864654517, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.447133871274774, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2d7c4db9-f57c-4683-9f7a-326a08a232cb", "name": "273da339-2e96-45f0-bf5a-361c5fabb759", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "02a872db-8965-4030-be6c-e5eba07a0186"}}}]}, {"uuid": "2da7ec48-a219-4860-b157-b952d788b1fd", "name": "load_p1rlv824_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20ce76b6-9305-4525-b77e-b7300edc2c81"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2d7c4db9-f57c-4683-9f7a-326a08a232cb"}}}}, {"uuid": "c25e60ea-748b-4dc8-91bd-11ba47a59b90", "name": "7705d927-687f-472f-9f3f-97f76e32d931_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.107858967059457, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3651352875232526, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ed082447-de8b-4db0-bcac-8321cd5b5865", "name": "dc510fb5-a27f-499e-aec2-85cfc57e665c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c25e60ea-748b-4dc8-91bd-11ba47a59b90"}}}]}, {"uuid": "1f09f953-cee0-45a4-a758-5408113a1b67", "name": "load_p1rlv825_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d209dff6-7a24-41ef-947a-8c6f79c2d65c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ed082447-de8b-4db0-bcac-8321cd5b5865"}}}}, {"uuid": "b148e492-bf6a-4644-97ab-97692805a008", "name": "4c356a34-1433-4277-8245-e8dd31188a15_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.107858967059457, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3651352875232526, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bd5e69ea-8e7b-4aa2-a197-465d10b3de6c", "name": "a23ea15f-02e5-4161-83df-0f68f951e1f5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b148e492-bf6a-4644-97ab-97692805a008"}}}]}, {"uuid": "2eae6474-5984-44cd-b557-74368e1ba0e5", "name": "load_p1rlv825_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d209dff6-7a24-41ef-947a-8c6f79c2d65c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bd5e69ea-8e7b-4aa2-a197-465d10b3de6c"}}}}, {"uuid": "6c33c342-8e5a-488a-b638-33e7ed70acb4", "name": "4d3811cd-4607-4ed9-b2a6-97940954c71a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.253869376169332, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.6228339639204339, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ce4c46dc-0f47-4985-bcbb-c278f75f57e5", "name": "820dcb99-deb3-45f7-8924-45da135769cc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c33c342-8e5a-488a-b638-33e7ed70acb4"}}}]}, {"uuid": "e1d6bb83-68ec-4e1c-8e31-96aaa50a140b", "name": "load_p1rlv826_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06746d4d-3db8-45b1-888e-d3d9e405ccaf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ce4c46dc-0f47-4985-bcbb-c278f75f57e5"}}}}, {"uuid": "a561e955-6cdb-4877-92b3-76a511ec69dd", "name": "6907b347-f27e-4119-81ce-258996b075ab_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.253869376169332, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.6228339639204339, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4d9d58e4-826f-4533-976a-07a74519c72c", "name": "5336a82c-6365-4ec0-808d-6e5f1c778f25", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a561e955-6cdb-4877-92b3-76a511ec69dd"}}}]}, {"uuid": "57fb6b3f-38b0-4c6b-896e-e458a17c2e13", "name": "load_p1rlv826_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06746d4d-3db8-45b1-888e-d3d9e405ccaf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4d9d58e4-826f-4533-976a-07a74519c72c"}}}}, {"uuid": "59863883-9c7c-4105-aad3-649bc7f1c86c", "name": "42a04cbe-98b1-4573-bbdb-a4ed8fefdb84_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7037919474579788, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6943112548118018, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a0da3511-7362-46bb-ad2b-e10a83884207", "name": "ba8319d8-b6c4-4d55-8ecd-2d7863eaa07c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "59863883-9c7c-4105-aad3-649bc7f1c86c"}}}]}, {"uuid": "97e3d9fc-8e5e-4414-b212-0538210a1add", "name": "load_p1rlv827_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c89db91-40fe-4de6-973e-5d8c23e35080"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a0da3511-7362-46bb-ad2b-e10a83884207"}}}}, {"uuid": "983a7419-bc91-4c68-9e29-fbe68f06fe48", "name": "1f6e40aa-31bc-4190-91b8-d783c587d4fe_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7037919474579788, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6943112548118018, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a361842b-d762-4198-ade6-c746a872ea4f", "name": "30b629ce-6a69-4159-996f-c797e585ae37", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "983a7419-bc91-4c68-9e29-fbe68f06fe48"}}}]}, {"uuid": "06acf64c-354f-444c-bf0c-99db6ed05d02", "name": "load_p1rlv827_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c89db91-40fe-4de6-973e-5d8c23e35080"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a361842b-d762-4198-ade6-c746a872ea4f"}}}}, {"uuid": "c0da35c7-38c3-4a5f-b49c-fd926354dc45", "name": "629fac6e-d544-4445-869f-cd6d0ef5e52c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8668291909105112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7572719732007044, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7fd263c3-70d0-417c-9a9f-204208d60db4", "name": "40370cd1-6e63-4ebf-a139-9431d9e4f6a0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c0da35c7-38c3-4a5f-b49c-fd926354dc45"}}}]}, {"uuid": "0667d89d-8655-4719-910e-b5c90e028e24", "name": "load_p1rlv828_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08c3f5ef-c2d5-4ce2-8fc7-b665d8cbbab6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7fd263c3-70d0-417c-9a9f-204208d60db4"}}}}, {"uuid": "cc6c55e1-5bfe-48df-8608-a17fa1321933", "name": "3959c432-385d-4a8d-89c9-41cd743eb8ca_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8668291909105112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7572719732007044, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "214e9093-d512-4c67-bf8a-ef70b8086f41", "name": "cbd2b3d4-fd43-4096-8e91-63b2907967d8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cc6c55e1-5bfe-48df-8608-a17fa1321933"}}}]}, {"uuid": "ea5bcc31-c953-4505-8c46-60511b2f876e", "name": "load_p1rlv828_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08c3f5ef-c2d5-4ce2-8fc7-b665d8cbbab6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "214e9093-d512-4c67-bf8a-ef70b8086f41"}}}}, {"uuid": "7ad6bc0c-b62f-44ae-9c37-ab3b4052d7c8", "name": "f30d3093-c727-47e3-baba-93875c057f3e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7400090938863744, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.257745187793523, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "401a8519-192c-42da-a41a-bdad27ed8419", "name": "0aa20863-91fe-49fe-a3ed-41231982e601", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7ad6bc0c-b62f-44ae-9c37-ab3b4052d7c8"}}}]}, {"uuid": "0ff83211-0502-4e70-a369-18a16f4ae90c", "name": "load_p1rlv829_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e3a1bd0-69fe-42bb-993d-2094ecc658ce"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "401a8519-192c-42da-a41a-bdad27ed8419"}}}}, {"uuid": "a4bf3895-2bb5-4ee3-8cfe-2e09c907fd8c", "name": "e6fa068a-bf15-4d7d-8332-e191453e2acd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7400090938863744, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.257745187793523, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eb8fdc59-30ac-483d-9df4-0dec6bb85ceb", "name": "7740e9e8-162d-4b41-8c1a-212cea502eb9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a4bf3895-2bb5-4ee3-8cfe-2e09c907fd8c"}}}]}, {"uuid": "299e04bb-1d60-423e-8d18-56645cf724fc", "name": "load_p1rlv829_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e3a1bd0-69fe-42bb-993d-2094ecc658ce"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eb8fdc59-30ac-483d-9df4-0dec6bb85ceb"}}}}, {"uuid": "91821f0d-42c1-443d-bab5-f4dbfa137736", "name": "6d6ba518-b330-41aa-8db4-9eee5d01dcf6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9541125560071345, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3732603805546264, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9608867c-46ad-4f6e-bad2-a4ebf473085b", "name": "03eaea5d-cfcd-4011-9944-96a383b5746f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "91821f0d-42c1-443d-bab5-f4dbfa137736"}}}]}, {"uuid": "b9160f40-3f3a-4063-b2c5-28972fb67dcc", "name": "load_p1rlv830_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b7538477-32ab-4db6-872d-83be7ec89fd9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9608867c-46ad-4f6e-bad2-a4ebf473085b"}}}}, {"uuid": "faae66b1-94b7-4b3f-a513-844e1d4e3b59", "name": "d939b1ac-1f94-4ebf-833e-d6c7748a8701_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9541125560071345, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3732603805546264, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "22ba8929-046b-4dda-a245-91697081fac6", "name": "b88128e3-e68d-4911-a40b-e6b57028509d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "faae66b1-94b7-4b3f-a513-844e1d4e3b59"}}}]}, {"uuid": "c080c3d3-8276-4554-85db-b92e863ffa05", "name": "load_p1rlv830_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b7538477-32ab-4db6-872d-83be7ec89fd9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "22ba8929-046b-4dda-a245-91697081fac6"}}}}, {"uuid": "610b56f9-d801-45ae-91db-df6cf2d35a48", "name": "853c8726-a620-4d7a-90e1-56e680eb8707_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.746284303820433, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6724067157838972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5ef1cd69-1981-4100-ae90-f109a7a00c4e", "name": "e3db4086-7eaf-4569-aff4-b6855d4845ff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "610b56f9-d801-45ae-91db-df6cf2d35a48"}}}]}, {"uuid": "717c1f69-4334-47b0-9273-fe51d52e1411", "name": "load_p1rlv831_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4b6c4e-78d0-4c8e-907c-619f1e43c149"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5ef1cd69-1981-4100-ae90-f109a7a00c4e"}}}}, {"uuid": "67766f61-4a1d-4ae4-949d-345e1fa00a3b", "name": "f577a9b9-c12a-4073-8d3b-edfaeceec0a7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.746284303820433, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6724067157838972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b309dd9b-3303-4986-bf5d-7b6a9125fbfa", "name": "30b217c3-5083-4f0f-83d1-5a83ff59cdec", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "67766f61-4a1d-4ae4-949d-345e1fa00a3b"}}}]}, {"uuid": "a9025d91-ecf5-40e7-a428-35f87c18338b", "name": "load_p1rlv831_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4b6c4e-78d0-4c8e-907c-619f1e43c149"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b309dd9b-3303-4986-bf5d-7b6a9125fbfa"}}}}, {"uuid": "afc3c4de-ab14-43a4-8d9e-9707108c6cb5", "name": "6bee1ada-96fe-4d3d-81f5-c1d0a73bad25_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.250267265771566, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8009319586825154, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ac573839-6e5c-4f36-9a7b-539fa20cd575", "name": "d8c6d513-2c81-4cfe-a307-6e39d448e951", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "afc3c4de-ab14-43a4-8d9e-9707108c6cb5"}}}]}, {"uuid": "0b4ab97a-46d5-4222-be17-9a01904cb32e", "name": "load_p1rlv832_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10373c0d-6a3c-4160-a174-22de447d4c38"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ac573839-6e5c-4f36-9a7b-539fa20cd575"}}}}, {"uuid": "7229411d-e4f1-4f2b-99a0-e7ba1ae18b31", "name": "35c3f57a-bf1f-413d-ad43-41a74ca34e27_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.250267265771566, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8009319586825154, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8b0cd29d-184f-4521-ad39-ea089bf07926", "name": "24c33887-3572-4423-9d5b-cdf7de2cbe5b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7229411d-e4f1-4f2b-99a0-e7ba1ae18b31"}}}]}, {"uuid": "7ba46c6f-ba1c-47d7-9b7a-06e1e5719ae1", "name": "load_p1rlv832_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10373c0d-6a3c-4160-a174-22de447d4c38"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8b0cd29d-184f-4521-ad39-ea089bf07926"}}}}, {"uuid": "9e1344e8-665f-4802-bc78-adc16aec041a", "name": "2bccc6c8-546c-4581-b75f-badf5b5cb7d4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1212324580541053, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5100712782164012, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2651276c-e3e2-4864-afc8-1da4343802b9", "name": "f3efb4cd-794e-4529-9c3c-341c54217828", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9e1344e8-665f-4802-bc78-adc16aec041a"}}}]}, {"uuid": "21b607ba-0654-4239-be2d-fadce2328dd7", "name": "load_p1rlv833_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eb57fc4-636d-4923-9f4a-d308b062599f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2651276c-e3e2-4864-afc8-1da4343802b9"}}}}, {"uuid": "f12af18a-47fa-47d1-a761-95ec62686d35", "name": "9886c5ae-49a6-4fa0-b833-409938e3701e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1212324580541053, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5100712782164012, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "49bcbe3a-fe71-406c-a18b-38410946c071", "name": "624ef648-caab-4363-9633-a4af7656fbae", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f12af18a-47fa-47d1-a761-95ec62686d35"}}}]}, {"uuid": "3dfe3a27-efa3-4260-a84f-c3af41c6c947", "name": "load_p1rlv833_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eb57fc4-636d-4923-9f4a-d308b062599f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "49bcbe3a-fe71-406c-a18b-38410946c071"}}}}, {"uuid": "828de88b-2da7-4949-a09d-a7e48e037427", "name": "fe52519e-3b08-4cdc-8dff-5c6c8dea6a26_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.107858967059457, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3651352875232526, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f2fbfcd4-8d69-47a6-af51-318cfac95969", "name": "1c968931-2b64-4deb-8271-85610cbaf286", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "828de88b-2da7-4949-a09d-a7e48e037427"}}}]}, {"uuid": "0d46b9b6-70f9-43ca-8440-b4e9bad211fa", "name": "load_p1rlv834_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d437c83c-cbd1-41bf-b455-21123e82d59f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f2fbfcd4-8d69-47a6-af51-318cfac95969"}}}}, {"uuid": "15c45dba-5e69-4c70-b57e-2ee55683f89b", "name": "bce8a9a9-d325-4088-bed5-f1e9efafb067_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.107858967059457, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3651352875232526, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b25d3f8b-b0bc-49a0-bbc9-2b0517ac3c39", "name": "04c293e5-c570-4ee9-be1c-98e3b93fcdd0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "15c45dba-5e69-4c70-b57e-2ee55683f89b"}}}]}, {"uuid": "56510e77-31ae-4502-8883-767e359af33c", "name": "load_p1rlv834_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d437c83c-cbd1-41bf-b455-21123e82d59f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b25d3f8b-b0bc-49a0-bbc9-2b0517ac3c39"}}}}, {"uuid": "308e0b97-6215-4e63-aecc-72d5a156ebd0", "name": "b591c622-741a-4b41-966e-7b0e3ac368f4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1426015471760884, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5928311844731246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "646a7475-4643-4898-805a-75f320668a09", "name": "7680aef7-bdbe-4eed-89a3-72d8d86ee122", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "308e0b97-6215-4e63-aecc-72d5a156ebd0"}}}]}, {"uuid": "f54d8273-6c0f-48c5-9266-581a386820c2", "name": "load_p1rlv835_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bc35476-5839-4095-bea5-36e32450b890"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "646a7475-4643-4898-805a-75f320668a09"}}}}, {"uuid": "a9b9efc3-5b10-4a82-ae2f-6772a746aa4d", "name": "7c4c87bf-59d0-4f19-a53d-841f529cb164_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1426015471760884, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5928311844731246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "657e4375-2b1e-420b-8447-a12cd7246c24", "name": "e6529a33-34f4-4c52-920d-4fbf92b78d5d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a9b9efc3-5b10-4a82-ae2f-6772a746aa4d"}}}]}, {"uuid": "8858b368-17f9-43a7-895a-67d5d3a09b35", "name": "load_p1rlv835_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bc35476-5839-4095-bea5-36e32450b890"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "657e4375-2b1e-420b-8447-a12cd7246c24"}}}}, {"uuid": "6b543206-afcc-4053-af5a-60eae057d2dd", "name": "9f53b4f5-d81a-4842-bb37-dab765efb4a0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.941898785419248, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8498359578625553, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "17c99f84-2e3f-4355-afd0-0e5d869deccb", "name": "9bd960e5-1579-4c69-a241-2c964d985a09", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6b543206-afcc-4053-af5a-60eae057d2dd"}}}]}, {"uuid": "625a15f2-f4b1-4664-becf-522994dfcc67", "name": "load_p1rlv836_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12556ab7-c50a-4624-9d84-b85585822245"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "17c99f84-2e3f-4355-afd0-0e5d869deccb"}}}}, {"uuid": "18b48cec-54f1-4030-8722-dc2c86f02589", "name": "bb4b9f21-c379-4328-9541-8879c5c3f1e8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.941898785419248, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8498359578625553, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5f7fb70e-fa24-40c4-b113-ee644f4111bd", "name": "424ea7c6-2b33-4b83-88f3-23b0ef04e6d9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "18b48cec-54f1-4030-8722-dc2c86f02589"}}}]}, {"uuid": "b434d51d-ba3f-4122-87f2-6ff564f6efdc", "name": "load_p1rlv836_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12556ab7-c50a-4624-9d84-b85585822245"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5f7fb70e-fa24-40c4-b113-ee644f4111bd"}}}}, {"uuid": "15ca6d0b-f87e-47b7-9e40-dab53f7172ed", "name": "745a9d60-cfb1-4af2-b253-0383da07e4e7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4663769608466568, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5502546109327153, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e1a94eab-8ce7-4787-b6c2-86c56ef4334e", "name": "48636bca-59fb-48b8-bdf7-303c97e0d622", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "15ca6d0b-f87e-47b7-9e40-dab53f7172ed"}}}]}, {"uuid": "8c7dd958-fab7-4776-90a0-0cc111dc9d1e", "name": "load_p1rlv837_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33492e0f-c907-46c6-a529-503480b642bb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e1a94eab-8ce7-4787-b6c2-86c56ef4334e"}}}}, {"uuid": "c813fd7f-5cc8-44e7-b411-b841482231f8", "name": "d0cf8302-c91b-43e5-90ed-f81efb1848d5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4663769608466568, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5502546109327153, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d004d951-a13f-4dfc-bbf9-e685e2ba6ccb", "name": "5659efd3-414f-444b-aaa0-0aa0e9454b67", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c813fd7f-5cc8-44e7-b411-b841482231f8"}}}]}, {"uuid": "5744bba1-a670-436a-b29c-c45ce46cfe5c", "name": "load_p1rlv837_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33492e0f-c907-46c6-a529-503480b642bb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d004d951-a13f-4dfc-bbf9-e685e2ba6ccb"}}}}, {"uuid": "e59167f2-ae8c-484a-aed5-6e7518c1e6b6", "name": "f76b109d-e72b-427d-a9aa-b13a297e3018_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3464174292990054, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8802812503815668, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "62c8c8bb-5f9f-42fe-9919-7742b22a5265", "name": "c92d20d8-9859-482f-82c6-033771a0b76b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e59167f2-ae8c-484a-aed5-6e7518c1e6b6"}}}]}, {"uuid": "20ab6f62-5c4e-4508-90ad-6fe1a71ab34a", "name": "load_p1rlv838_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7ffe87d-4424-4495-83c1-6765d385207c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "62c8c8bb-5f9f-42fe-9919-7742b22a5265"}}}}, {"uuid": "c82016b9-e40e-4e2a-b866-4c0541f9db78", "name": "adeda6f9-bfa2-4159-8b66-912227216c35_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3464174292990054, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8802812503815668, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ff51bfab-4d8d-4e23-9397-b7eb2553ca6e", "name": "e31a30f3-80b5-43ae-b498-a38eb7e2f8db", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c82016b9-e40e-4e2a-b866-4c0541f9db78"}}}]}, {"uuid": "a0507800-213a-4e03-b02b-72090c6c2e93", "name": "load_p1rlv838_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7ffe87d-4424-4495-83c1-6765d385207c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ff51bfab-4d8d-4e23-9397-b7eb2553ca6e"}}}}, {"uuid": "8791ab4c-c618-4962-a1ef-ae457fefd9f1", "name": "b7168462-c24d-43bb-b983-55d3b9b9c877_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3086582709384027, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12628327836733033, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0d61d9c4-026e-44a3-9fc9-57e3a534a981", "name": "8b80649c-86e8-4ea2-9fc4-c25a8da3d6ae", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8791ab4c-c618-4962-a1ef-ae457fefd9f1"}}}]}, {"uuid": "5c2fe452-6368-42d8-b1f6-801d4285f1e9", "name": "load_p1rlv839_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48e97be9-1f80-457f-a56e-79f54458c620"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0d61d9c4-026e-44a3-9fc9-57e3a534a981"}}}}, {"uuid": "e9891289-6645-40d0-b3f4-3fe938d4bf4f", "name": "a9c3ba8d-6e50-4b4b-b2ee-49b081413bb5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3086582709384027, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12628327836733033, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "709a13e8-7896-411c-8060-b8656b4b1b2d", "name": "079e76c7-3459-47d4-b774-90bfc1ec9ccd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e9891289-6645-40d0-b3f4-3fe938d4bf4f"}}}]}, {"uuid": "2a329d21-97c6-47ac-a98c-2406bd17b0cc", "name": "load_p1rlv839_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48e97be9-1f80-457f-a56e-79f54458c620"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "709a13e8-7896-411c-8060-b8656b4b1b2d"}}}}, {"uuid": "01bc638c-a479-4e7d-805a-d7137f576946", "name": "eafe6c48-c593-468e-880b-d8c42d7e1e87_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4950137537296666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31506625700854357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "de546a87-f52b-4343-b6d8-ee5fdc026203", "name": "d42df018-de45-407f-9f08-2f702c2f0468", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "01bc638c-a479-4e7d-805a-d7137f576946"}}}]}, {"uuid": "990c975d-7dac-4138-ae0e-698b5d9d1b39", "name": "load_p1rlv840_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "024961c3-25f4-4a15-a52a-7f88dc652766"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "de546a87-f52b-4343-b6d8-ee5fdc026203"}}}}, {"uuid": "ec04d3e5-797c-48a5-8ab7-57dd0a77a3c9", "name": "9f29c20c-d852-4c24-877d-0bbb7058be6c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4950137537296666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31506625700854357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f42e8ec-3919-43ad-9346-b9ee5da3f499", "name": "4332240a-aa4d-464f-88a9-7b0f4ae0b295", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ec04d3e5-797c-48a5-8ab7-57dd0a77a3c9"}}}]}, {"uuid": "ab9f5e05-2970-4924-8a85-aae4fe263b3e", "name": "load_p1rlv840_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "024961c3-25f4-4a15-a52a-7f88dc652766"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f42e8ec-3919-43ad-9346-b9ee5da3f499"}}}}, {"uuid": "9785cfe5-256a-486d-a324-1bd5f30a5e19", "name": "1702e774-78fc-4206-b45b-14bb4f2aa4ba_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9614713621548963, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.170985110067395, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "475962a7-6780-4135-86e3-009d5d683a6b", "name": "7ca65b02-a7da-434d-9c31-f495b72c312c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9785cfe5-256a-486d-a324-1bd5f30a5e19"}}}]}, {"uuid": "cfa6d704-c332-44d1-ba2e-31172bba49da", "name": "load_p1rlv841_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eb6c1b4-f09a-44a5-a13f-64051183736d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "475962a7-6780-4135-86e3-009d5d683a6b"}}}}, {"uuid": "8f3aa178-a4a2-4884-b53f-a8f2409614ba", "name": "16a86396-039a-474c-aa5f-a2e098358315_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9614713621548963, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.170985110067395, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "04943b34-4a8a-422e-aef7-d4470dc9b981", "name": "2c38238e-59a3-4fd1-93ff-671ebc712e95", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8f3aa178-a4a2-4884-b53f-a8f2409614ba"}}}]}, {"uuid": "e7720fb8-1f33-4c47-be4b-88e5a430b611", "name": "load_p1rlv841_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eb6c1b4-f09a-44a5-a13f-64051183736d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "04943b34-4a8a-422e-aef7-d4470dc9b981"}}}}, {"uuid": "b7af79f8-1862-46b0-b51f-0c825baf15d9", "name": "64556f90-f1e4-4e44-a053-a9d536fb1e79_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8285317723273034, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9836303634928509, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "48ca5f56-bf1f-45f8-b8bb-9b040ded4573", "name": "0b6cf306-da1f-4286-a5a2-521ba012fd54", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b7af79f8-1862-46b0-b51f-0c825baf15d9"}}}]}, {"uuid": "0940874a-e752-42c9-90ae-e7be990bb853", "name": "load_p1rlv842_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8f304a4-6e39-4288-9b9b-e41bb37c6019"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "48ca5f56-bf1f-45f8-b8bb-9b040ded4573"}}}}, {"uuid": "627dcd89-b96d-4c13-8abd-b98c9111fd73", "name": "df20d7e6-68c2-4695-b4f1-fa4ca288c8dc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8285317723273034, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9836303634928509, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8ba1a638-dfb0-4e1d-b530-78df11b9d5f1", "name": "cb3c7422-da41-45c7-9a9d-993d5a4a6897", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "627dcd89-b96d-4c13-8abd-b98c9111fd73"}}}]}, {"uuid": "cb3eaf0a-c353-43bc-94b1-764ed209ad42", "name": "load_p1rlv842_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8f304a4-6e39-4288-9b9b-e41bb37c6019"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8ba1a638-dfb0-4e1d-b530-78df11b9d5f1"}}}}, {"uuid": "9829bdca-2176-4d31-8c70-d08643ab2027", "name": "59648600-ec8c-4903-afae-2622087f494a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7943609059660943, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8824322096654456, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b701fec3-1eb1-4beb-b725-fb95c0b2c7c7", "name": "86103c0d-dcad-49b9-aa08-f4b555bae597", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9829bdca-2176-4d31-8c70-d08643ab2027"}}}]}, {"uuid": "13454edd-3943-4d68-9ce7-b08db819335a", "name": "load_p1rlv843_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3bc013f-c78d-4a3c-b27f-826c3025de0e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b701fec3-1eb1-4beb-b725-fb95c0b2c7c7"}}}}, {"uuid": "36e9cb2d-c336-43c7-958f-597584a7b4d6", "name": "ce8e56f3-a73d-41f0-97db-1f768e25f537_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7943609059660943, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8824322096654456, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c4a7ab30-c1ad-4ce7-97b2-2604f23ea4f3", "name": "6a5bd58b-6aba-407c-9d12-4cc182b603fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "36e9cb2d-c336-43c7-958f-597584a7b4d6"}}}]}, {"uuid": "eb0a4e99-8354-47ec-a036-a49ce41f9bcc", "name": "load_p1rlv843_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3bc013f-c78d-4a3c-b27f-826c3025de0e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c4a7ab30-c1ad-4ce7-97b2-2604f23ea4f3"}}}}, {"uuid": "ffa75d2e-5c98-4afa-b23b-f70dd0be73a3", "name": "ed64f055-1c53-4159-a244-06b2e908e817_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.062987656442733, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.2699236524876967, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ca2f73cf-b69b-4011-ab51-ca490b35fd76", "name": "3facab19-f51f-47e3-b137-1a3803f920ee", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ffa75d2e-5c98-4afa-b23b-f70dd0be73a3"}}}]}, {"uuid": "946b5b25-8afa-4bde-9b2a-c736d884eec9", "name": "load_p1rlv844_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26294827-db76-40b6-b652-1e41efdf15dc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ca2f73cf-b69b-4011-ab51-ca490b35fd76"}}}}, {"uuid": "c6f6f984-64c4-4396-89fd-c9c47042fc28", "name": "b62398c0-d470-441b-a912-a47fced3a655_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.062987656442733, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.2699236524876967, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "28fc005b-75dd-46c7-b9db-d5e8c6127aa1", "name": "772310ab-cafb-49ea-8f32-60a74196f0f6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c6f6f984-64c4-4396-89fd-c9c47042fc28"}}}]}, {"uuid": "a7e0dcd0-a7c6-4adb-b88f-f492af62b272", "name": "load_p1rlv844_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26294827-db76-40b6-b652-1e41efdf15dc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "28fc005b-75dd-46c7-b9db-d5e8c6127aa1"}}}}, {"uuid": "b4003b35-2b3b-4af0-8de4-604977581c97", "name": "8cb5ff7f-5aef-42bf-9119-a05dad52b9f9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.910200682298975, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5555412020426419, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ab226e6d-82fd-41e8-b993-5b84b51eb4ff", "name": "39b0862f-feb7-4da5-885d-73d78e073189", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b4003b35-2b3b-4af0-8de4-604977581c97"}}}]}, {"uuid": "8376fc1a-b59f-43cb-a5a8-44d0b44d29ab", "name": "load_p1rlv845_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b053d449-b15b-4292-9a73-9b7d104a8e38"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ab226e6d-82fd-41e8-b993-5b84b51eb4ff"}}}}, {"uuid": "c3958938-cbd3-472a-9c99-95806bb84b3f", "name": "f59a083b-e6d9-4685-aeb1-0cf60622c86e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.910200682298975, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5555412020426419, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "00461c76-6c87-4612-bc51-1d0989527a7b", "name": "0c09ca8e-8769-4600-a588-90eca8873146", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c3958938-cbd3-472a-9c99-95806bb84b3f"}}}]}, {"uuid": "d0b71404-56b4-4fe4-ab8d-b5cf552f66b9", "name": "load_p1rlv845_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b053d449-b15b-4292-9a73-9b7d104a8e38"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "00461c76-6c87-4612-bc51-1d0989527a7b"}}}}, {"uuid": "a55e9cf6-429f-4c71-87de-16ec31853880", "name": "a262e4df-1fef-433b-9ab9-abd8ae469f43_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.772705532239135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.33568286747913667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fa5a99e8-9d11-4954-acc6-47fc1451bbac", "name": "4fcfc64d-9655-48a4-9536-f39ed0b9f374", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a55e9cf6-429f-4c71-87de-16ec31853880"}}}]}, {"uuid": "638ffa96-1e7e-4d99-8bee-907f52cbcc88", "name": "load_p1rlv846_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "145d3757-ca09-45ca-9199-465b6b43fbb7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fa5a99e8-9d11-4954-acc6-47fc1451bbac"}}}}, {"uuid": "2929e2ac-0e30-46eb-b71b-5364e978fe8d", "name": "8365ebed-ff8a-4203-a100-4913109d1bdd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.772705532239135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.33568286747913667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fb5a7159-cbc6-49b0-b1cb-ebcc1dec4b1a", "name": "f5d2c0ae-6b91-4a0b-8817-e22c4ba36710", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2929e2ac-0e30-46eb-b71b-5364e978fe8d"}}}]}, {"uuid": "fec9c5f7-9aa9-48ac-92b1-e3d93fee3c65", "name": "load_p1rlv846_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "145d3757-ca09-45ca-9199-465b6b43fbb7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fb5a7159-cbc6-49b0-b1cb-ebcc1dec4b1a"}}}}, {"uuid": "fa3f6062-4671-4203-8049-c4fad65a9237", "name": "5ecc8f7c-532c-4803-93d5-a8b2ff8bf3aa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2075389461119934, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3167249782629938, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "33d3cde7-a420-435c-8b91-31dfe50c2860", "name": "50247295-4690-4540-bb6a-ccbbdb6d5bf7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fa3f6062-4671-4203-8049-c4fad65a9237"}}}]}, {"uuid": "9c473154-b8b2-4064-9a6a-89dc5a54b69f", "name": "load_p1rlv847_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "283142ff-4884-4adc-9d4c-f8615505415a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "33d3cde7-a420-435c-8b91-31dfe50c2860"}}}}, {"uuid": "c9fc333b-5a54-4b28-a6d4-cd6ccdfe2b6b", "name": "53b25bbb-72d0-4a3d-86a3-0fa55219cfd3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2075389461119934, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3167249782629938, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "969e7e4a-dd5b-46ae-b883-2eb2b40f848b", "name": "e35fb445-415a-4951-853a-47d951f12a41", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9fc333b-5a54-4b28-a6d4-cd6ccdfe2b6b"}}}]}, {"uuid": "14a2504d-01b8-4aac-8748-b0376320ab33", "name": "load_p1rlv847_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "283142ff-4884-4adc-9d4c-f8615505415a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "969e7e4a-dd5b-46ae-b883-2eb2b40f848b"}}}}, {"uuid": "c09d2a7a-d38b-4a5f-86b4-9aea3f3f91b7", "name": "cb6907ad-7410-4473-b3f4-3da1ba202a27_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4794755457968312, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.46197673612457824, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6d3e07b4-1a35-48c9-8adc-6f52113102d6", "name": "e8755510-0e03-4a73-9cce-6b4a79f27838", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c09d2a7a-d38b-4a5f-86b4-9aea3f3f91b7"}}}]}, {"uuid": "4ebbbbb3-7e08-4715-aceb-51a122998f2f", "name": "load_p1rlv848_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e484d77-29ac-4903-afa3-f677283db883"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6d3e07b4-1a35-48c9-8adc-6f52113102d6"}}}}, {"uuid": "51a4e04c-711d-4bd6-8316-c648e2b89856", "name": "6235b454-706d-49e7-ac71-a9344113b912_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4794755457968312, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.46197673612457824, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fd740f4a-7f4c-4795-9bd3-939ec892f916", "name": "d30fa4e9-56e8-4d00-8ca9-0f242173d56f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "51a4e04c-711d-4bd6-8316-c648e2b89856"}}}]}, {"uuid": "5a98bb20-7c07-4b1b-bd7b-d5c289466cf2", "name": "load_p1rlv848_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e484d77-29ac-4903-afa3-f677283db883"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fd740f4a-7f4c-4795-9bd3-939ec892f916"}}}}, {"uuid": "8cab14d9-0a0f-40bf-9b68-d1e2e46939f8", "name": "fd72b7b0-105f-4add-bbd1-d9df40e05337_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.292799122473319, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5385753507809203, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cf07e1f2-31e7-488d-bdb8-479391d57add", "name": "c9581250-75c5-46bd-bb58-d7a7bbd303f7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8cab14d9-0a0f-40bf-9b68-d1e2e46939f8"}}}]}, {"uuid": "4472bb76-70f3-44ff-9d15-46518c7d0d04", "name": "load_p1rlv849_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a95877ca-8600-4e95-82ac-c51cb82acf16"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cf07e1f2-31e7-488d-bdb8-479391d57add"}}}}, {"uuid": "da281240-6876-4756-b99e-99707b3e4b53", "name": "b446a498-18f1-40f2-b50d-fe77f39b60b8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.292799122473319, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5385753507809203, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7e6c224f-9f73-450b-9560-75283650ef2c", "name": "98426f92-904d-4b94-b1e0-99d6c346f267", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "da281240-6876-4756-b99e-99707b3e4b53"}}}]}, {"uuid": "a388bf38-0fb8-4c4b-8736-53457df89b59", "name": "load_p1rlv849_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a95877ca-8600-4e95-82ac-c51cb82acf16"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7e6c224f-9f73-450b-9560-75283650ef2c"}}}}, {"uuid": "079e87a7-2dcf-4c41-82c1-d355db6fd5b7", "name": "da6e5544-3742-4ded-9307-e762416cee5e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.737986692242784, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8906640815201406, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b71072af-4d15-4d1d-bfc9-3edcda196026", "name": "e94dd721-a476-469d-a978-b2f77a3e172c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "079e87a7-2dcf-4c41-82c1-d355db6fd5b7"}}}]}, {"uuid": "b4ac23ec-155a-40fd-85f4-77c43c345631", "name": "load_p1rlv850_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d49057-9c70-4489-95bb-36b5b574e13d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b71072af-4d15-4d1d-bfc9-3edcda196026"}}}}, {"uuid": "c95ac71a-681f-4509-9eba-895a289012d8", "name": "e333efe5-158e-43aa-bdac-155844fbd620_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.737986692242784, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8906640815201406, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "87ddf4da-1542-4022-ad08-cf51913dcf99", "name": "178dc8e1-2375-4a0d-b439-b31c05197025", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c95ac71a-681f-4509-9eba-895a289012d8"}}}]}, {"uuid": "ae73fe56-081e-4996-9bff-d4b073c8dd98", "name": "load_p1rlv850_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d49057-9c70-4489-95bb-36b5b574e13d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "87ddf4da-1542-4022-ad08-cf51913dcf99"}}}}, {"uuid": "938176d6-c264-46f9-b916-44fa987b069a", "name": "2d46fa4e-175e-4ec6-b74d-5dfa3815b18e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6295328634326751, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9988748196040309, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f74787d6-5835-45fa-9290-422bed794f4d", "name": "fa19786d-68d6-4c6a-a062-9235f7c8dfee", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "938176d6-c264-46f9-b916-44fa987b069a"}}}]}, {"uuid": "8a15f266-4f98-4288-8ba5-263a877aeb48", "name": "load_p1rlv851_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48b5535c-f00d-4b48-a23a-87f3f212302f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f74787d6-5835-45fa-9290-422bed794f4d"}}}}, {"uuid": "6b120a3a-f663-4d9f-a57c-ddfd8f2dec4b", "name": "ca2a0e01-00ff-4ef4-aaa5-8aae694aea9f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6295328634326751, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9988748196040309, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fb9087aa-1791-47a4-adeb-a6547ac17b6c", "name": "31097e7a-9eec-4dfa-9a62-3b613bf8bf26", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6b120a3a-f663-4d9f-a57c-ddfd8f2dec4b"}}}]}, {"uuid": "ac397b0f-76ec-4e36-b6c8-415905f2bb6f", "name": "load_p1rlv851_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48b5535c-f00d-4b48-a23a-87f3f212302f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fb9087aa-1791-47a4-adeb-a6547ac17b6c"}}}}, {"uuid": "c2a1f7b5-19ab-47aa-937f-05f52627dddc", "name": "659a36bd-a7aa-4dec-9acf-d31fbb16260a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.072248840478098, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4856137999354615, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f9ad31eb-3ffb-4797-a746-b1604ab4f2b7", "name": "2bdc508a-656f-4100-861f-98a999f72776", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c2a1f7b5-19ab-47aa-937f-05f52627dddc"}}}]}, {"uuid": "32ef83b5-8cc7-4a68-93b8-41764a6abcaa", "name": "load_p1rlv852_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32142941-c546-4356-ba80-123b9128b5de"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f9ad31eb-3ffb-4797-a746-b1604ab4f2b7"}}}}, {"uuid": "86075a23-c51e-49ba-af91-77ff46df6dd3", "name": "01103004-1ff0-4f2c-99f8-3cc408fc55a0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.072248840478098, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4856137999354615, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c6d823a9-35a7-45f1-b243-e78bf6fe23b5", "name": "36396a64-3c5d-4b86-945a-0b3d3cd6d5db", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "86075a23-c51e-49ba-af91-77ff46df6dd3"}}}]}, {"uuid": "ae20b46b-5e41-4a03-9a59-55b7522c841d", "name": "load_p1rlv852_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32142941-c546-4356-ba80-123b9128b5de"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c6d823a9-35a7-45f1-b243-e78bf6fe23b5"}}}}, {"uuid": "96605a2b-6efd-43aa-8a81-f5fc0dba3f0e", "name": "deaf567c-a026-4554-a0a7-687792ab63e9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0307394237991176, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0095205649117913, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "123eebfc-2042-4715-ab91-25732d479e72", "name": "c4872abd-c3bc-4209-8802-bc99fe0f02c3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "96605a2b-6efd-43aa-8a81-f5fc0dba3f0e"}}}]}, {"uuid": "0f13dd75-128f-4674-8647-5b56add5b599", "name": "load_p1rlv853_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "365eff25-8ccb-448b-894f-ad662fe6d684"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "123eebfc-2042-4715-ab91-25732d479e72"}}}}, {"uuid": "8facf6cb-c11b-4172-92b8-83e781a3b8f1", "name": "7cd73183-8983-48c8-b26e-296f3dbe8117_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0307394237991176, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0095205649117913, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "95f41b66-dea3-421b-8f9a-154274c833cf", "name": "9e2d777a-b466-42de-837a-34372aee43f6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8facf6cb-c11b-4172-92b8-83e781a3b8f1"}}}]}, {"uuid": "758828f8-84b9-4627-aa37-55b2e0484323", "name": "load_p1rlv853_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "365eff25-8ccb-448b-894f-ad662fe6d684"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "95f41b66-dea3-421b-8f9a-154274c833cf"}}}}, {"uuid": "717840ac-6dd6-4827-bd43-a554fb72da8c", "name": "d0ee04c6-6faf-4755-9ffa-0969c8e06caf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.621947646480353, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0332384495271123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "64472809-31e9-4821-a8a2-607cb1c44575", "name": "aaa6b3c4-c3d3-457f-b6a7-c3ab9f5eb44e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "717840ac-6dd6-4827-bd43-a554fb72da8c"}}}]}, {"uuid": "9bb9e900-0cbe-480f-b913-d84926db0a02", "name": "load_p1rlv854_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2461b6f0-9a40-4b6f-9669-be479da039f3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "64472809-31e9-4821-a8a2-607cb1c44575"}}}}, {"uuid": "16562700-f4db-4517-abbb-5aa91fff7652", "name": "d3a5a834-ea15-484f-9dde-fcdb1d49033b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.621947646480353, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0332384495271123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cfd37b6d-06db-482a-afb3-8fa4f7a686b5", "name": "411c31b0-e7a3-40e7-adda-02517fe0908e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "16562700-f4db-4517-abbb-5aa91fff7652"}}}]}, {"uuid": "b83a0389-140e-4844-80a2-41f2bffe2b90", "name": "load_p1rlv854_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2461b6f0-9a40-4b6f-9669-be479da039f3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cfd37b6d-06db-482a-afb3-8fa4f7a686b5"}}}}, {"uuid": "f600b2dc-6cdb-4b19-97ad-d56551e79ab4", "name": "e150596e-4503-4ecf-9026-bf049ae0d6fc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.037961707989467, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3691190849967326, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "224dd4bd-f3ff-4f50-97d3-2fdc005e0de3", "name": "ed0f82f0-768d-456c-b6e9-0ee41ce84c6a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f600b2dc-6cdb-4b19-97ad-d56551e79ab4"}}}]}, {"uuid": "7a5ba2e4-3885-4be5-b672-99b3fae2d8c3", "name": "load_p1rlv855_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10611e08-75e2-4422-ac0f-cfb98c7eae4b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "224dd4bd-f3ff-4f50-97d3-2fdc005e0de3"}}}}, {"uuid": "6e323aa2-ba11-48d0-81ef-41387111c606", "name": "eac6cc37-cbe4-4fb4-8a1d-bc90e9fa3754_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.037961707989467, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3691190849967326, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5c3af5ce-5414-41ea-9c5c-89efe6d0d90a", "name": "93900ca9-c875-4baf-81a9-4f3c3d29dace", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6e323aa2-ba11-48d0-81ef-41387111c606"}}}]}, {"uuid": "ceb6e0a6-d1af-4b49-83a3-ec99e79b538f", "name": "load_p1rlv855_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10611e08-75e2-4422-ac0f-cfb98c7eae4b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5c3af5ce-5414-41ea-9c5c-89efe6d0d90a"}}}}, {"uuid": "6df6841e-86ca-4dec-8dcd-4d1e7737d659", "name": "98ba7850-57fc-45a0-b3e0-7d705b57c157_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0599252267318962, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3748861224482183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "84f46b25-5bba-449b-bb71-0fd1708d7b9c", "name": "e9e7e068-991b-428e-bba2-5378e50498cc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6df6841e-86ca-4dec-8dcd-4d1e7737d659"}}}]}, {"uuid": "621bdbbe-256c-4cc9-be75-89226e86b452", "name": "load_p1rlv856_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25f84b28-695b-4d32-b96c-914226444b9f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "84f46b25-5bba-449b-bb71-0fd1708d7b9c"}}}}, {"uuid": "04f372ca-5429-44cc-8e92-039e9872f677", "name": "c7fc900a-9761-4cd4-8341-b345266840fb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0599252267318962, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3748861224482183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1166a1ab-a5b1-456c-8bd7-a71a202292ff", "name": "d9b7e884-83d2-470d-bda2-9909f008c41d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "04f372ca-5429-44cc-8e92-039e9872f677"}}}]}, {"uuid": "ae996b2d-1dea-4f61-99a5-a53fcb898980", "name": "load_p1rlv856_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25f84b28-695b-4d32-b96c-914226444b9f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1166a1ab-a5b1-456c-8bd7-a71a202292ff"}}}}, {"uuid": "9b8f6789-1de8-413d-a3c4-5410bef958a2", "name": "88d15826-274e-4901-8860-5e4d7a9c38d6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7943609059660943, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8824322096654456, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2eeb66ef-6a15-4ad6-add3-1a48e608df1b", "name": "c859bfb6-b1e9-467f-a6ba-c0a872cd4dac", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9b8f6789-1de8-413d-a3c4-5410bef958a2"}}}]}, {"uuid": "2afb5f2d-a7d6-4d0d-814f-9ed02e37d632", "name": "load_p1rlv857_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a28cc17a-125d-4b7b-a697-230e3f8853b5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2eeb66ef-6a15-4ad6-add3-1a48e608df1b"}}}}, {"uuid": "9aa8e408-47da-4da3-b3eb-a373bf49b2b0", "name": "b4a34dc0-77f6-48fd-974b-3e39b8b29a49_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7943609059660943, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8824322096654456, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "234024af-de66-4b33-8129-d6b8059bdd80", "name": "75c1079f-de07-4098-bd81-29f4198fc437", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9aa8e408-47da-4da3-b3eb-a373bf49b2b0"}}}]}, {"uuid": "094df460-37a3-4b56-a3b9-f5b2b6be0ba3", "name": "load_p1rlv857_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a28cc17a-125d-4b7b-a697-230e3f8853b5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "234024af-de66-4b33-8129-d6b8059bdd80"}}}}, {"uuid": "7323b44d-a2c5-4f50-b500-5800eb2f378e", "name": "a23685aa-5fd7-4cf5-a7a7-40e6e2203420_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.360087651208046, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7361845082285076, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a1c70345-7ac7-4ce2-a973-c7c9094de834", "name": "9a73ab21-8bd4-42fc-8948-6e32c8dee34d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7323b44d-a2c5-4f50-b500-5800eb2f378e"}}}]}, {"uuid": "2d3bce52-a0d9-407c-9a3d-47bad3f824a1", "name": "load_p1rlv858_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab33ce2f-3131-4cfb-8df2-329fb4aa76b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a1c70345-7ac7-4ce2-a973-c7c9094de834"}}}}, {"uuid": "a75b42ea-cf4f-482a-818d-e620e774eaba", "name": "6cd91bc1-b5b9-4e8d-9a2a-e6ae360b7edb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.360087651208046, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7361845082285076, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a51406a8-a8d8-4294-a054-2829c350a2c5", "name": "0b07e4b1-3489-4d32-9b21-cdb8c09841d9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a75b42ea-cf4f-482a-818d-e620e774eaba"}}}]}, {"uuid": "bd4c08fd-1f86-4ca0-861b-d97428390c2a", "name": "load_p1rlv858_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab33ce2f-3131-4cfb-8df2-329fb4aa76b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a51406a8-a8d8-4294-a054-2829c350a2c5"}}}}, {"uuid": "35086a57-9857-4866-a09e-231dd9f6fca0", "name": "e8a02a80-3e02-43f8-86aa-0139292ee6c8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.292799122473319, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5385753507809203, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "092c0dd2-64c4-4fdb-b042-0fba4bd9bd72", "name": "b309218d-ff40-4e21-b696-16d8cb4504e8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "35086a57-9857-4866-a09e-231dd9f6fca0"}}}]}, {"uuid": "ea82bf4d-44fc-471f-bb20-faa13e025ddc", "name": "load_p1rlv859_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ea0f4f5-2024-45a8-9f8f-f5963e7d2727"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "092c0dd2-64c4-4fdb-b042-0fba4bd9bd72"}}}}, {"uuid": "15eca634-df48-414d-a350-28d6a67c60ac", "name": "10d83fbf-95e7-4c47-84ea-795b3e674406_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.292799122473319, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5385753507809203, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4f3dd59b-9b2a-4fa7-b2f0-77b46d74ea85", "name": "5909bc2c-6ea9-400d-a1ac-7ec4cf3b3195", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "15eca634-df48-414d-a350-28d6a67c60ac"}}}]}, {"uuid": "1d319791-32ab-4a13-9b3a-4c28dfee0e16", "name": "load_p1rlv859_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ea0f4f5-2024-45a8-9f8f-f5963e7d2727"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4f3dd59b-9b2a-4fa7-b2f0-77b46d74ea85"}}}}, {"uuid": "3946463d-5ba0-4265-99c7-f95fda7d6324", "name": "c226f9fe-97d4-4f13-a604-ed5ef5335011_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5424601784243566, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31457775613808403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9b716c1f-225f-4a38-b498-7f218bc827ff", "name": "ec4ad5d1-316c-48cc-adf4-d43151ae92d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3946463d-5ba0-4265-99c7-f95fda7d6324"}}}]}, {"uuid": "5ea998e1-259b-4b48-86ae-f263a6e51b5c", "name": "load_p1rlv860_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bada1117-5605-4aec-9314-8013ed243e3c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9b716c1f-225f-4a38-b498-7f218bc827ff"}}}}, {"uuid": "39e0e2ea-3427-41a3-a24c-f874143fd4cf", "name": "c975a955-75c7-4e7c-b1bf-c42d83f0ee8d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5424601784243566, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31457775613808403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ab3bcd05-6f6f-4d10-8807-13db4da37a09", "name": "90e3bd87-98c5-4cff-b849-90a6c5e49d55", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "39e0e2ea-3427-41a3-a24c-f874143fd4cf"}}}]}, {"uuid": "087c8d07-6c8a-4ea0-8c2e-36d042741e85", "name": "load_p1rlv860_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bada1117-5605-4aec-9314-8013ed243e3c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ab3bcd05-6f6f-4d10-8807-13db4da37a09"}}}}, {"uuid": "b615cda8-1baf-4369-99b6-e1aa112b1d04", "name": "b0859b4f-82e2-43c9-a5e7-4d90cbf261fc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2766983969851713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5028612878254624, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2b07c294-9599-4629-ab6a-de6a01d14c82", "name": "e7546a56-0a12-4d9c-8664-ed7e6eb841c1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b615cda8-1baf-4369-99b6-e1aa112b1d04"}}}]}, {"uuid": "96800c02-0db3-4db9-b8b6-28b7fc263295", "name": "load_p1rlv861_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a07d30f-6909-4d74-be8a-1ff8343b4419"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2b07c294-9599-4629-ab6a-de6a01d14c82"}}}}, {"uuid": "4659d82a-2d77-4710-82ac-960b753b0425", "name": "3bbc9222-9155-4c7a-9d39-cb8512724ca8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2766983969851713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5028612878254624, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "72a5a44c-ba79-466f-abea-f385d63ff89d", "name": "e23362be-3012-4f38-9444-437cf2f9fb67", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4659d82a-2d77-4710-82ac-960b753b0425"}}}]}, {"uuid": "1cf2e81e-bfb4-48c2-9ef3-c4244e1d4176", "name": "load_p1rlv861_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a07d30f-6909-4d74-be8a-1ff8343b4419"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "72a5a44c-ba79-466f-abea-f385d63ff89d"}}}}, {"uuid": "36119b84-0eeb-4a54-a521-ea143e122c70", "name": "f8af5d24-b499-47a4-bf61-a9a39a38a305_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.037961707989467, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3691190849967326, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aaa7a400-9669-453e-987b-e49830388166", "name": "b597c1da-1f78-4424-92de-98ee97ef58bd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "36119b84-0eeb-4a54-a521-ea143e122c70"}}}]}, {"uuid": "49da019f-d34e-4676-a7c3-83d7fdd9f1d1", "name": "load_p1rlv862_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5e2c3a2-32c0-4bb9-9802-265cec784974"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aaa7a400-9669-453e-987b-e49830388166"}}}}, {"uuid": "5006d372-3b1d-408c-abe2-6f3208eac730", "name": "ba8b441d-bec1-43f1-8574-b8a92ff222ba_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.037961707989467, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3691190849967326, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f31efed1-ba00-4062-ab30-6e483d25fc84", "name": "210c84bb-bc4c-4f53-ad8c-625114ae5c83", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5006d372-3b1d-408c-abe2-6f3208eac730"}}}]}, {"uuid": "fd3a664f-196a-43fa-bfdc-53efd02af17c", "name": "load_p1rlv862_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5e2c3a2-32c0-4bb9-9802-265cec784974"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f31efed1-ba00-4062-ab30-6e483d25fc84"}}}}, {"uuid": "ace38ad0-adb5-413b-b79d-668ae95cb220", "name": "ceae3b7d-532d-4b92-a59b-64dee73af957_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1350143243427975, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1351898450115188, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d7fbc366-1f07-41d0-bec5-af65c6df29d4", "name": "15d9ac3c-7a40-46a9-9835-115380acddf0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ace38ad0-adb5-413b-b79d-668ae95cb220"}}}]}, {"uuid": "5966ebaa-cfd3-4095-ade4-1f653ab63ea7", "name": "load_p1rlv863_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09a7be46-a1bf-459d-836b-beb64324809b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d7fbc366-1f07-41d0-bec5-af65c6df29d4"}}}}, {"uuid": "1d53c84b-81f1-420c-8482-438a751eed35", "name": "3da80d10-b10f-4974-a8f9-5dd2816e5bd9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1350143243427975, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1351898450115188, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "37c8776e-dbfe-404b-b52e-a7685eca1be1", "name": "e545727b-1cfe-4117-be2f-530ecedfdadf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1d53c84b-81f1-420c-8482-438a751eed35"}}}]}, {"uuid": "7033a7f2-be4e-454a-a54a-997dfcea2f79", "name": "load_p1rlv863_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09a7be46-a1bf-459d-836b-beb64324809b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "37c8776e-dbfe-404b-b52e-a7685eca1be1"}}}}, {"uuid": "679bc03a-95ec-4dac-b478-740fb11b7f8b", "name": "026f57e0-a554-4cd6-aff1-1162bc769970_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0404861968223509, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5307917165881004, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0b92cee6-e830-479d-98b9-5b58f61604e9", "name": "d677f903-718f-4ebe-acc8-9aa5591d70a4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "679bc03a-95ec-4dac-b478-740fb11b7f8b"}}}]}, {"uuid": "7fb1a340-9cdd-4d27-87c6-975d10aab344", "name": "load_p1rlv864_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e2a8871-7bc4-497f-9954-38db92cb3eba"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0b92cee6-e830-479d-98b9-5b58f61604e9"}}}}, {"uuid": "51792ec8-29d7-4f26-8ccf-07b1c59ea1fe", "name": "441a7382-13b0-4a4b-a9cb-a6efc1080bce_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0404861968223509, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5307917165881004, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50e57df0-1fc7-4e3b-a217-56d086a3f85d", "name": "f845ac47-866f-4ed9-bd8d-b7b2968e8703", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "51792ec8-29d7-4f26-8ccf-07b1c59ea1fe"}}}]}, {"uuid": "5f436709-285d-4efc-b7a5-b90e8d251195", "name": "load_p1rlv864_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e2a8871-7bc4-497f-9954-38db92cb3eba"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50e57df0-1fc7-4e3b-a217-56d086a3f85d"}}}}, {"uuid": "38cc0407-c5ca-4e8b-89f6-76d0f546dc24", "name": "222da507-c072-4b19-a029-97d7de16ca33_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.396349422902612, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13402564403017767, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a83ec3a0-5d64-4bfe-ae1a-d5fb9a412442", "name": "d6ed423b-17ab-463e-9c6f-6c4ea05e864c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "38cc0407-c5ca-4e8b-89f6-76d0f546dc24"}}}]}, {"uuid": "c2714419-2921-4ab1-b9c6-5aa354bac9c6", "name": "load_p1rlv865_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abdfa5db-c398-4638-805d-6d55597e1921"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a83ec3a0-5d64-4bfe-ae1a-d5fb9a412442"}}}}, {"uuid": "8144f7d5-cfad-47c7-bc29-c99638c052ee", "name": "5a0fbef2-a383-4d19-b9b5-a19466da2dcf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.396349422902612, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13402564403017767, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6527d9ad-e156-4133-acb9-f3e5763eec6c", "name": "d1944846-4e8d-4ef5-8a4c-1555100cb335", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8144f7d5-cfad-47c7-bc29-c99638c052ee"}}}]}, {"uuid": "13136e7a-d669-4975-b669-a1c432915c92", "name": "load_p1rlv865_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abdfa5db-c398-4638-805d-6d55597e1921"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6527d9ad-e156-4133-acb9-f3e5763eec6c"}}}}, {"uuid": "42bfd63a-37b3-4f04-8158-3ef4471651bf", "name": "3f3992b8-a126-4bb3-b05c-89840855c1f0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3885774782241163, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12624891415512582, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "560745e8-0452-43ef-81d7-630181294706", "name": "cce335ea-f452-48ad-8707-9c2d3280e24c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "42bfd63a-37b3-4f04-8158-3ef4471651bf"}}}]}, {"uuid": "b2b6fa33-8085-4b64-82cd-4fe96219ea44", "name": "load_p1rlv866_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b4834dc-6bdf-4102-bc13-589392b2e75a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "560745e8-0452-43ef-81d7-630181294706"}}}}, {"uuid": "968e05c7-a79f-4514-a3de-87e33419cff2", "name": "85ae0cf9-82bc-4d01-b049-fcd4b6fb9ac1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3885774782241163, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12624891415512582, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d1de2c42-fc5f-4cb4-92ec-5e9beac9c261", "name": "c12a43c2-a29e-4bcd-bdeb-7a0306225d8c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "968e05c7-a79f-4514-a3de-87e33419cff2"}}}]}, {"uuid": "faa57801-b454-43b6-bdda-eeaafa76b9e8", "name": "load_p1rlv866_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b4834dc-6bdf-4102-bc13-589392b2e75a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d1de2c42-fc5f-4cb4-92ec-5e9beac9c261"}}}}, {"uuid": "1c879820-7c35-46b9-8168-00f7e509aef4", "name": "403f8627-c8d6-40e8-bfcb-47c03dcf74d8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6434260893942235, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2588956175598443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "171928bd-80b9-42bb-a91e-b9ab7ae8989a", "name": "f8b5b9e7-4f04-4cdd-bb13-380da2aeb0ea", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1c879820-7c35-46b9-8168-00f7e509aef4"}}}]}, {"uuid": "c6967476-77ef-442f-bfdb-222f6502e733", "name": "load_p1rlv867_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a7cca48-fd4b-4630-a479-55f2b6ada03b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "171928bd-80b9-42bb-a91e-b9ab7ae8989a"}}}}, {"uuid": "114181e2-86b0-4925-9cc9-0d7ca64c7407", "name": "1c2a3eea-1172-431e-87b2-17ad9df21235_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6434260893942235, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2588956175598443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "28a7f3f9-cd2e-428a-a9bd-d33a2e4fed11", "name": "0de580cd-f883-4a16-8008-61a93c33a7da", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "114181e2-86b0-4925-9cc9-0d7ca64c7407"}}}]}, {"uuid": "385a2115-4295-4941-a7fb-a59564b4f508", "name": "load_p1rlv867_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a7cca48-fd4b-4630-a479-55f2b6ada03b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "28a7f3f9-cd2e-428a-a9bd-d33a2e4fed11"}}}}, {"uuid": "b9f7f963-fb43-4e1e-871d-38f0d87206ca", "name": "a1d0da70-7bc9-493c-94ef-abe966f8bcdb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b25e2402-e84a-4a40-80a0-ce8be1a5322b", "name": "2e2a91d1-2bc1-4316-a111-5371893ddf75", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b9f7f963-fb43-4e1e-871d-38f0d87206ca"}}}]}, {"uuid": "2e469aa9-dbf8-4b95-8f28-e8a2fb8c1ea1", "name": "load_p1rlv868_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "009758e3-b4ae-427a-9c30-f2a8bb2953d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b25e2402-e84a-4a40-80a0-ce8be1a5322b"}}}}, {"uuid": "8328adfe-9dc1-4885-b0eb-17be3134c569", "name": "18746686-2a2d-4f4e-bad6-fd16dbe2a33f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "467c6f11-7830-4b68-b6d9-a210abde83f1", "name": "18413f31-a538-4d0d-bd03-11a127f553d3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8328adfe-9dc1-4885-b0eb-17be3134c569"}}}]}, {"uuid": "547a971b-dbf5-4c1f-91ab-7385e3c89f7a", "name": "load_p1rlv868_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "009758e3-b4ae-427a-9c30-f2a8bb2953d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "467c6f11-7830-4b68-b6d9-a210abde83f1"}}}}, {"uuid": "eb92c93e-422c-40d0-b704-4fc3df412ad6", "name": "ffe3ad19-366b-4fd2-9f71-a5b150b6eb7c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.338024948143216, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9096814401074484, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d3416bc5-2dff-48ff-a630-f670458c570d", "name": "d0e0e291-1ed0-4993-8ee3-a05937ce6327", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eb92c93e-422c-40d0-b704-4fc3df412ad6"}}}]}, {"uuid": "4d86c288-ca8d-41fb-8c4d-b10435f7da15", "name": "load_p1rlv869_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fb4003d-498a-494d-89ca-f222d921f63a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d3416bc5-2dff-48ff-a630-f670458c570d"}}}}, {"uuid": "3201dcf9-4b41-468e-a205-000c11004b4e", "name": "6dcbacc4-865b-4a74-be53-090263776564_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.338024948143216, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9096814401074484, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b7edcd35-a7b1-48bc-af27-1b3853eb3475", "name": "6f04df3d-66d0-447a-92b9-abd6bf18984b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3201dcf9-4b41-468e-a205-000c11004b4e"}}}]}, {"uuid": "61512b03-7ff1-4d52-8b9f-426e1d071061", "name": "load_p1rlv869_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fb4003d-498a-494d-89ca-f222d921f63a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b7edcd35-a7b1-48bc-af27-1b3853eb3475"}}}}, {"uuid": "c5372011-7783-401d-9a42-ba2d894a238e", "name": "f1f19423-67b8-402b-8984-0f898b9811cf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4212042062341066, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7562106926743815, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7dbdc0a2-3f64-4373-859d-3a26df047799", "name": "eb64a4e4-6070-40ec-bc13-6a2922d7cd73", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c5372011-7783-401d-9a42-ba2d894a238e"}}}]}, {"uuid": "4d51d8cd-d0e6-4b8e-a4ad-5247983a09be", "name": "load_p1rlv7783_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd7a84bb-8aa4-4668-9791-a363741823e9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7dbdc0a2-3f64-4373-859d-3a26df047799"}}}}, {"uuid": "356fabb2-65b3-430b-a312-5aa18a3c401c", "name": "13d0f027-f3af-4bb2-82ae-f9bbfede334a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4212042062341066, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7562106926743815, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7341ff5f-3431-4fc3-8e0b-f52c7bc7373a", "name": "d5d33575-ebee-4695-b382-0da403d99f1f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "356fabb2-65b3-430b-a312-5aa18a3c401c"}}}]}, {"uuid": "e04e1abb-c60f-41f0-a774-c47db62edcb7", "name": "load_p1rlv7783_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd7a84bb-8aa4-4668-9791-a363741823e9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7341ff5f-3431-4fc3-8e0b-f52c7bc7373a"}}}}, {"uuid": "1713edaf-ac0f-44a1-98ba-b0cce436bc52", "name": "17302292-37b7-4d04-a4ad-5f84bccad702_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7101501378288513, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4527501720520811, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0199c07e-7ae5-4eae-8840-bc887b10f47c", "name": "21e0d40f-8044-479d-8281-30ccfe9937af", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1713edaf-ac0f-44a1-98ba-b0cce436bc52"}}}]}, {"uuid": "96a58958-439a-468e-b3d9-56cbf024da8c", "name": "load_p1rlv7784_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24e665a0-3ba6-46a7-bc02-327b6f77c409"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0199c07e-7ae5-4eae-8840-bc887b10f47c"}}}}, {"uuid": "dcdf6c24-e443-4d30-b513-55002574edab", "name": "b5c7351b-44db-4dad-a029-13aaf73a1b56_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7101501378288513, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4527501720520811, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "96ae4a60-29b4-4c2a-994d-969e5605b8e5", "name": "ba592037-68f9-4d58-8f80-54b47f0019dc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dcdf6c24-e443-4d30-b513-55002574edab"}}}]}, {"uuid": "0dd29067-5363-4676-abfc-354c6ff02846", "name": "load_p1rlv7784_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24e665a0-3ba6-46a7-bc02-327b6f77c409"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "96ae4a60-29b4-4c2a-994d-969e5605b8e5"}}}}, {"uuid": "1f4bd4b8-5e77-4a63-b4ce-b7fb5e07d7d7", "name": "00369e15-8a8a-4925-b8e2-ab8a0b504b7f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7392455382108751, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4362253237121403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "810e40dc-14f6-45be-b35f-0f870f133692", "name": "5b77ab36-8077-415f-aa20-26ad0a9095f3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1f4bd4b8-5e77-4a63-b4ce-b7fb5e07d7d7"}}}]}, {"uuid": "b29d32c3-c841-4de0-a9bb-6c3bd598ecf0", "name": "load_p1rlv7785_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1571d1a3-a151-4972-8cb1-aeb36b660abc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "810e40dc-14f6-45be-b35f-0f870f133692"}}}}, {"uuid": "fe5e92cf-14d5-40c8-80c9-994efda6330b", "name": "2c63d8f0-6314-4200-907f-007d8fdc7b8a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7392455382108751, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4362253237121403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8eb3fe60-7f0f-4d31-96ea-b471cece8da8", "name": "010de59b-39bf-4135-9331-e5121db1ff1d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fe5e92cf-14d5-40c8-80c9-994efda6330b"}}}]}, {"uuid": "491c2e8e-4768-402a-9265-b6aed108f402", "name": "load_p1rlv7785_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1571d1a3-a151-4972-8cb1-aeb36b660abc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8eb3fe60-7f0f-4d31-96ea-b471cece8da8"}}}}, {"uuid": "c4d52b83-c123-4dad-a510-e4e0acb90ef8", "name": "86cc9856-6517-480c-bd1f-5cb3042f8f64_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4818511326065424, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6748395523926414, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e73684a1-b61e-4422-a2d1-b6d0db4ad5cb", "name": "e55cf8bd-e951-4401-887c-da8167795169", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c4d52b83-c123-4dad-a510-e4e0acb90ef8"}}}]}, {"uuid": "199b5478-37e0-4ed6-8017-12a45432003a", "name": "load_p1rlv7786_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af62e3c-9357-4505-a2f6-3b4252dab81b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e73684a1-b61e-4422-a2d1-b6d0db4ad5cb"}}}}, {"uuid": "34a004b2-eea5-415a-8e47-262212d2a7d5", "name": "d016a180-f514-4118-b5ab-0bee72e27724_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4818511326065424, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6748395523926414, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "105167fd-90f0-40a8-a0b1-c598a4aff4a7", "name": "26f2e62d-d3bb-478c-b5ad-f367a0eca836", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "34a004b2-eea5-415a-8e47-262212d2a7d5"}}}]}, {"uuid": "3dd5337e-db69-4d76-b98f-47d0ed2a0fa6", "name": "load_p1rlv7786_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af62e3c-9357-4505-a2f6-3b4252dab81b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "105167fd-90f0-40a8-a0b1-c598a4aff4a7"}}}}, {"uuid": "98e8bc3a-ae30-47a4-b7d1-281b95a25c74", "name": "457cbb44-1f6e-4e4a-a8d2-a1c3fd8ad123_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9705664843982345, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20295664886439999, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10ff4285-30ed-41a3-8f7e-9ebc82a27b21", "name": "5374c77e-7f21-431e-a7b2-e576db6ca92a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "98e8bc3a-ae30-47a4-b7d1-281b95a25c74"}}}]}, {"uuid": "5377086a-e04a-491c-8e54-efd38306a144", "name": "load_p1rlv10453_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09926231-b077-4aa6-afd8-acf89744865a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10ff4285-30ed-41a3-8f7e-9ebc82a27b21"}}}}, {"uuid": "8a0a012e-28ce-42d7-a4bd-9ee349d700bc", "name": "25f0cc32-c195-40fb-83d4-0d08a5fdd278_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9705664843982345, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20295664886439999, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fbc1bd32-f7d7-4287-adfb-b99cc1a70bc5", "name": "d67682f3-c1e0-4618-abe0-2b29d2af39ff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a0a012e-28ce-42d7-a4bd-9ee349d700bc"}}}]}, {"uuid": "bd7d0a1e-d67b-4a4e-a2c0-a7a1b73037af", "name": "load_p1rlv10453_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09926231-b077-4aa6-afd8-acf89744865a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fbc1bd32-f7d7-4287-adfb-b99cc1a70bc5"}}}}, {"uuid": "10730986-0710-4e81-990f-23beb309d894", "name": "c2d3e7d3-19b1-44f4-b6fa-b8cd5157c579_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9288135994675786, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3237835349774649, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4db3bb81-f55f-4f61-a851-1a862c76b727", "name": "58e3f632-f96c-40e1-a83e-23ef309dba25", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "10730986-0710-4e81-990f-23beb309d894"}}}]}, {"uuid": "3a7f5ff3-b2dd-454a-99fc-5b591d560ba5", "name": "load_p1rlv10468_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a639e8d-ac8c-46e8-a4b5-6c551612b209"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4db3bb81-f55f-4f61-a851-1a862c76b727"}}}}, {"uuid": "c7776e75-cfc5-4157-8f3a-7503c9711283", "name": "20e4f9b1-b0fa-458b-b0ce-e9170c32f91d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9288135994675786, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3237835349774649, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a6dc196c-5ae1-4ab2-805f-2810cbff7632", "name": "5083f26e-7835-4fd1-93f4-b27ec12194b4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c7776e75-cfc5-4157-8f3a-7503c9711283"}}}]}, {"uuid": "339c7105-f33b-45e5-abcf-ef13c4974cbf", "name": "load_p1rlv10468_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a639e8d-ac8c-46e8-a4b5-6c551612b209"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a6dc196c-5ae1-4ab2-805f-2810cbff7632"}}}}, {"uuid": "c1025d61-e42a-41dd-8a3c-2bb129424d05", "name": "a10cf00c-67ac-4213-ad57-a683b93ef409_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.137360281336931, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.443734948632237, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c8407680-4514-4a23-a4e1-14107c4aa215", "name": "00e230a2-ffb8-423f-88ad-611c74946da7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c1025d61-e42a-41dd-8a3c-2bb129424d05"}}}]}, {"uuid": "d5c520ff-f7a9-48be-870b-1d2208006878", "name": "load_p1rlv10482_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d40fc87f-1b73-4ed4-a397-dbc94312dcad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c8407680-4514-4a23-a4e1-14107c4aa215"}}}}, {"uuid": "6634dc96-29a7-43b5-81a6-334cba43847c", "name": "e237970c-6462-4344-af07-c9d1ad1343a4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.137360281336931, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.443734948632237, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e887fdb7-614b-4d04-b57a-0d1cc3fd571e", "name": "00e2e47e-f8b0-489e-947f-2a9f364dce18", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6634dc96-29a7-43b5-81a6-334cba43847c"}}}]}, {"uuid": "997faa1f-d5f7-441a-869d-4e69da540525", "name": "load_p1rlv10482_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d40fc87f-1b73-4ed4-a397-dbc94312dcad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e887fdb7-614b-4d04-b57a-0d1cc3fd571e"}}}}, {"uuid": "fe4be1fd-0512-4eb7-9f7f-11886ff23ff1", "name": "64750c64-f3ba-45b1-816b-750e7b1e9b4d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.982015016710447, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5720113989287618, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "078f82f7-4f75-410d-a499-337abb2ebaac", "name": "3e87d6fc-2a31-40a4-9ce4-830ded723b7a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fe4be1fd-0512-4eb7-9f7f-11886ff23ff1"}}}]}, {"uuid": "cca90958-3097-4288-b429-b28e1fd1caf7", "name": "load_p1rlv10517_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "efd01236-6ba3-424e-829b-3f3950ce6265"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "078f82f7-4f75-410d-a499-337abb2ebaac"}}}}, {"uuid": "a170ae41-2689-494f-aa57-d9df60f90d08", "name": "c9c3960e-61bf-4a9b-bba7-44c9143e27e6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.982015016710447, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5720113989287618, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "269b3854-5224-400f-839d-f2b589390694", "name": "d192040d-7e21-4a69-b5fb-8ea8137bca90", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a170ae41-2689-494f-aa57-d9df60f90d08"}}}]}, {"uuid": "36344287-a32a-46aa-a960-835474341ea3", "name": "load_p1rlv10517_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "efd01236-6ba3-424e-829b-3f3950ce6265"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "269b3854-5224-400f-839d-f2b589390694"}}}}, {"uuid": "adcf0a93-9a94-431d-9ebc-6835e5a8059a", "name": "2036e332-5afc-465e-9d87-d99c6f411b95_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.160991762543576, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9056130261441641, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2c486189-5467-480d-a6ad-ae7c6290458c", "name": "eaabd49c-a213-4fd5-9cca-291701c002fa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "adcf0a93-9a94-431d-9ebc-6835e5a8059a"}}}]}, {"uuid": "65822cb1-153e-4fbc-8610-1b9fc2dc485c", "name": "load_p1rlv11503_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "773a6b9e-d708-4f7c-a901-9406bcc3dcde"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2c486189-5467-480d-a6ad-ae7c6290458c"}}}}, {"uuid": "6799b0b2-e42f-4ddc-bc71-b87a75fc8f59", "name": "edc9e2eb-7c62-47ab-ba2c-c1119079824a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.160991762543576, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9056130261441641, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c30fe11c-27f9-4a6f-8a66-50f3396162a4", "name": "834f3ff6-6233-4dd4-a5a0-dafe3f984f1b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6799b0b2-e42f-4ddc-bc71-b87a75fc8f59"}}}]}, {"uuid": "6949907d-ea62-46ba-b015-cc5a3054b94b", "name": "load_p1rlv11503_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "773a6b9e-d708-4f7c-a901-9406bcc3dcde"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c30fe11c-27f9-4a6f-8a66-50f3396162a4"}}}}, {"uuid": "320bb1ad-fb4a-4e8a-991d-a2cef4662f2b", "name": "45904608-adc0-44ee-b20b-377a44260f1c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 15.606876661659024, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.2167580478298823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a224ecb-4f16-4ea5-8f6f-384ece3a523c", "name": "45904608-adc0-44ee-b20b-377a44260f1c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 15.606876661659024, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.2167580478298823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "68e57e33-9943-44b8-b264-b5560c1d4b4c", "name": "45904608-adc0-44ee-b20b-377a44260f1c_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 15.606876661659024, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.2167580478298823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4748482d-bd45-4d2c-870e-3fb5e1a21449", "name": "a4709721-35d1-451c-abcd-4ef6fdbb9e7c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "320bb1ad-fb4a-4e8a-991d-a2cef4662f2b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0a224ecb-4f16-4ea5-8f6f-384ece3a523c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "68e57e33-9943-44b8-b264-b5560c1d4b4c"}}}]}, {"uuid": "1c4e8311-a62b-4a80-b43d-dc5ded5311c3", "name": "load_p1rlv11506", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "82988650-787d-41de-bca7-4f3c08ccad15"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4748482d-bd45-4d2c-870e-3fb5e1a21449"}}}}, {"uuid": "95c9105d-b00f-4e2d-932b-b74067800d34", "name": "cefbed57-dfef-4d79-b045-a385ca1060a0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 10.178690882168185, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.8011442962112136, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4addb2d3-a678-4527-be47-baab300fcbc5", "name": "1bf14111-5b0a-48df-9573-c9b4a0915629", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "95c9105d-b00f-4e2d-932b-b74067800d34"}}}]}, {"uuid": "be46345e-157c-4ee5-8acb-761ea129e52c", "name": "load_p1rlv11513_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84b9d44e-2c8d-4cee-a9d2-327a41ab8dad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4addb2d3-a678-4527-be47-baab300fcbc5"}}}}, {"uuid": "a8ab0468-5638-4f7a-8350-694c2857b3b2", "name": "abaaafc3-3725-42e3-a946-bd918dcaad8f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 10.178690882168185, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.8011442962112136, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ec915dd7-5306-43d9-aa73-5e9131b64835", "name": "c54f0076-4198-48b3-b38d-657bf46d4e2e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a8ab0468-5638-4f7a-8350-694c2857b3b2"}}}]}, {"uuid": "622a3b87-1a77-42d7-ba31-d9a7b2703765", "name": "load_p1rlv11513_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84b9d44e-2c8d-4cee-a9d2-327a41ab8dad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ec915dd7-5306-43d9-aa73-5e9131b64835"}}}}, {"uuid": "c66757e7-156b-47a2-bf3c-60b350e5671b", "name": "227d777e-40c2-48b4-90bb-65961da9a105_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2659851154673674, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7880475847724098, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0b50e2b1-205e-433c-9316-e198d133f206", "name": "54b20506-3d9b-4132-851d-4475eebc75b2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c66757e7-156b-47a2-bf3c-60b350e5671b"}}}]}, {"uuid": "a94a1d11-35e4-461d-ba20-7085e88df6a2", "name": "load_p1rlv11516_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86d82a1e-1596-4fb3-9f3d-44c9553396d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0b50e2b1-205e-433c-9316-e198d133f206"}}}}, {"uuid": "9cb4e692-7ff1-4d87-82a1-033a7139968e", "name": "791e23e8-102a-43c4-baa3-d5c8ae44f2d8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2659851154673674, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7880475847724098, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d679bb72-207d-4856-892d-58dd46d23339", "name": "c7194d59-734a-4c7d-839b-5429638241f6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9cb4e692-7ff1-4d87-82a1-033a7139968e"}}}]}, {"uuid": "050ba298-c20a-4ec0-beb3-b94e3808c5ec", "name": "load_p1rlv11516_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86d82a1e-1596-4fb3-9f3d-44c9553396d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d679bb72-207d-4856-892d-58dd46d23339"}}}}, {"uuid": "e89a76ae-f8b2-42fb-a46a-b59b5774aa94", "name": "10fb628e-fe01-4f5b-b631-dd5fda3853b9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.902887215219663, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.111231385342157, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10ea2792-e7fa-4609-8180-c5ffb4d298ea", "name": "e8c790b6-8571-498c-b018-36135359b8db", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e89a76ae-f8b2-42fb-a46a-b59b5774aa94"}}}]}, {"uuid": "8299b35d-b954-47de-8828-e54a4b3d5896", "name": "load_p1rlv11517_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "179d1d84-0dfe-4920-a039-009f33bc1d8d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10ea2792-e7fa-4609-8180-c5ffb4d298ea"}}}}, {"uuid": "9653af9d-2182-458d-b7b2-1dc199a9116d", "name": "6017e7e0-c29c-4d8b-8bde-e5e9ca1f6340_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.902887215219663, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.111231385342157, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a479e565-1151-4019-80aa-a642f090d9be", "name": "0ab2c7d4-ca0c-4bcc-af61-7866d7984102", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9653af9d-2182-458d-b7b2-1dc199a9116d"}}}]}, {"uuid": "b740edad-3e1a-4df3-afce-70e52538d492", "name": "load_p1rlv11517_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "179d1d84-0dfe-4920-a039-009f33bc1d8d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a479e565-1151-4019-80aa-a642f090d9be"}}}}, {"uuid": "bccabf64-2cc5-4387-9063-037efea74407", "name": "1861f9e2-4187-4864-b570-207cc6126bb6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.815209062299411, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.284220525554307, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7f72e181-164e-4eca-9e0b-189f57e4a521", "name": "1861f9e2-4187-4864-b570-207cc6126bb6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.815209062299411, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.284220525554307, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d62011ec-36d9-4fd0-b81f-4d5f7e76902d", "name": "1861f9e2-4187-4864-b570-207cc6126bb6_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.815209062299411, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.284220525554307, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "615c3356-445c-4f98-b970-8b8bcf87321c", "name": "e30959d0-13f7-44fe-86ec-b383372d22e1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bccabf64-2cc5-4387-9063-037efea74407"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7f72e181-164e-4eca-9e0b-189f57e4a521"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d62011ec-36d9-4fd0-b81f-4d5f7e76902d"}}}]}, {"uuid": "2948aa17-5f03-4d92-9ea6-60b285cfde09", "name": "load_p1rlv11520", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22054033-4e69-41b0-b321-a4d086d20574"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "615c3356-445c-4f98-b970-8b8bcf87321c"}}}}, {"uuid": "376e485b-5ffb-4d5a-ab9c-64c132605a26", "name": "0650d81b-3963-4552-9f0d-b6acae375567_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.368937976023913, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.122061037955929, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e7fbaefc-92c8-4fa6-a238-3e6675385749", "name": "6d7f0b7e-8a13-40aa-91d7-3116020e24e4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "376e485b-5ffb-4d5a-ab9c-64c132605a26"}}}]}, {"uuid": "24ac8477-c762-4578-83f9-36c4764ce044", "name": "load_p1rlv11521_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8f0f8a2-f528-45bd-8fbd-22f6699fe7e0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e7fbaefc-92c8-4fa6-a238-3e6675385749"}}}}, {"uuid": "caae9a53-cd7f-4831-9508-c2fee2b76934", "name": "0a722b1d-473f-4b6c-95f4-4fbd79aa4363_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.368937976023913, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.122061037955929, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f0b2e0be-2a69-47bc-afc9-0bb2f64630a5", "name": "b13519da-e21b-4c44-92a3-01a34458956d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "caae9a53-cd7f-4831-9508-c2fee2b76934"}}}]}, {"uuid": "80fb38d5-a103-45ea-86fb-d8189b370241", "name": "load_p1rlv11521_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8f0f8a2-f528-45bd-8fbd-22f6699fe7e0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f0b2e0be-2a69-47bc-afc9-0bb2f64630a5"}}}}, {"uuid": "4fed72ed-a1e0-4262-aaaf-9c856ccf37b2", "name": "52385853-2633-446a-b93e-aa1b1774eb15_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.71666338297624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.8739990837811158, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0aae9508-102f-4e20-96f8-94b35ed671f6", "name": "52385853-2633-446a-b93e-aa1b1774eb15_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.71666338297624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.8739990837811158, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cc9d9e94-7981-4ee8-bcbf-f5701ba564c1", "name": "52385853-2633-446a-b93e-aa1b1774eb15_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.71666338297624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.8739990837811158, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2a91d892-91c6-46ae-8e47-a9f3b59fc4eb", "name": "41d8b914-1843-44e5-9884-4acfb3532ffa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4fed72ed-a1e0-4262-aaaf-9c856ccf37b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0aae9508-102f-4e20-96f8-94b35ed671f6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cc9d9e94-7981-4ee8-bcbf-f5701ba564c1"}}}]}, {"uuid": "c6a2d41d-89f4-40a1-ae53-15df7b87dd3d", "name": "load_p1rlv11522", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "176b348f-9ecf-4a82-bdf9-f2e5d5a07af7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2a91d892-91c6-46ae-8e47-a9f3b59fc4eb"}}}}, {"uuid": "2e1897ab-fffe-4051-9e23-ec687c8aef6d", "name": "c465d6c6-c4fd-4311-bd32-332bd93cf1cb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 20.596071016561904, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.1080231298812775, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2c067e42-b521-4917-b01a-4328455c627c", "name": "e109b65b-daae-4732-99bc-a5349c5862f2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2e1897ab-fffe-4051-9e23-ec687c8aef6d"}}}]}, {"uuid": "f928863f-0387-490e-b720-40d3ac320fcc", "name": "load_p1rlv11523_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69eba934-3f80-4abc-b5e8-9cdc79aa05a3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2c067e42-b521-4917-b01a-4328455c627c"}}}}, {"uuid": "e0a9ad2d-dbd1-4237-b3e2-5ec5a2c10f3a", "name": "9bcd81db-6dfb-40ba-bf8d-fd41202caeaf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 20.596071016561904, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.1080231298812775, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4899fddb-d844-4080-b45a-7bccd4a40de6", "name": "994ac187-1add-4de4-94e1-448e7bd00ee9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e0a9ad2d-dbd1-4237-b3e2-5ec5a2c10f3a"}}}]}, {"uuid": "a80e2788-c6e3-46ce-955b-5bef549c5386", "name": "load_p1rlv11523_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69eba934-3f80-4abc-b5e8-9cdc79aa05a3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4899fddb-d844-4080-b45a-7bccd4a40de6"}}}}, {"uuid": "65d4d5d7-783c-4164-9c8c-6c80d4c32877", "name": "fbee6fff-73fa-44c2-88bb-e8f585e06115_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.560490892963857, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.302618625091914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10815e19-d32c-4147-a949-9fef4a5bc497", "name": "4ab78c27-a37e-49bf-b595-8b2419cac41f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "65d4d5d7-783c-4164-9c8c-6c80d4c32877"}}}]}, {"uuid": "d8524e9d-cf8b-47cd-92c0-a98c04a69555", "name": "load_p1rlv11526_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b97ebb0-09a4-4c42-a10e-e3aff344aa44"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10815e19-d32c-4147-a949-9fef4a5bc497"}}}}, {"uuid": "51e5b752-3e23-46c1-9104-8d1d07336b1f", "name": "088aeaee-f16d-455b-b6d9-55ceb9ab8cb3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.560490892963857, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.302618625091914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d2e76bd6-ce54-4e45-afc2-c40a892add08", "name": "88cdaf35-1444-46f0-8a69-9a7b75dfe1b2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "51e5b752-3e23-46c1-9104-8d1d07336b1f"}}}]}, {"uuid": "262f3cf0-072f-4bb0-ae69-bed19095daee", "name": "load_p1rlv11526_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b97ebb0-09a4-4c42-a10e-e3aff344aa44"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d2e76bd6-ce54-4e45-afc2-c40a892add08"}}}}, {"uuid": "081b87d0-9953-4e94-a14c-6869f5aff188", "name": "9e28f35b-2950-4018-b931-ce4c4c0e68c5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.930214175792893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.08514782397789, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c4f46244-6662-4298-a101-badc385e322a", "name": "a13bffde-fdec-4d49-9362-91ba5f7576b4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "081b87d0-9953-4e94-a14c-6869f5aff188"}}}]}, {"uuid": "9a43a335-3b65-4527-a2e0-01cfe39458a8", "name": "load_p1rlv11533_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21b18539-fba6-4b52-b8bf-38c2a6c4abfb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c4f46244-6662-4298-a101-badc385e322a"}}}}, {"uuid": "99521e7b-f1a6-438c-98d8-173782182e76", "name": "bab3eb24-732d-46b7-8d01-cd470539adfe_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.930214175792893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.08514782397789, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4fd952c7-7b2a-4e24-9952-342418d3823b", "name": "9ff22554-db4e-4376-8f63-da8436d1a4e4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "99521e7b-f1a6-438c-98d8-173782182e76"}}}]}, {"uuid": "8b08b8fd-c3d6-4cf2-84f5-3a95d96b51ad", "name": "load_p1rlv11533_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21b18539-fba6-4b52-b8bf-38c2a6c4abfb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4fd952c7-7b2a-4e24-9952-342418d3823b"}}}}, {"uuid": "ddf295d3-4ca7-45b8-bab0-2d2bedc79adf", "name": "164eb96d-8724-440d-841e-984dfc18b446_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.679125701108364, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8113232260660387, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "11b71362-a9ff-4ef3-91d7-b68749e0d98c", "name": "ae9b73d9-29a3-4d82-a958-b574c12d172e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ddf295d3-4ca7-45b8-bab0-2d2bedc79adf"}}}]}, {"uuid": "0920b786-6c42-4116-a887-236dade23449", "name": "load_p1rlv11540_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f79b14c8-e77d-49c1-9336-e7407ad4c94d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "11b71362-a9ff-4ef3-91d7-b68749e0d98c"}}}}, {"uuid": "8e30adb3-f06b-4cd3-bb78-0d53c73b9a12", "name": "a65e0dea-444d-422c-859a-f131dddcc40d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.679125701108364, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8113232260660387, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5b1b211b-f5c6-4161-9358-4937f7abcf73", "name": "9a4b4965-a41b-4d43-a8a7-48fa3accb31f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8e30adb3-f06b-4cd3-bb78-0d53c73b9a12"}}}]}, {"uuid": "e4f076a8-8c21-4468-995f-cb3d3a523c31", "name": "load_p1rlv11540_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f79b14c8-e77d-49c1-9336-e7407ad4c94d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5b1b211b-f5c6-4161-9358-4937f7abcf73"}}}}, {"uuid": "4fa4e50c-0268-4490-9d23-af532cb741af", "name": "ed9a947f-533f-4db7-9220-295975ae80ed_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c32e1d70-5898-46d9-bdfe-474a13392868", "name": "68ccf7df-d110-494b-be42-8264b9530d4d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4fa4e50c-0268-4490-9d23-af532cb741af"}}}]}, {"uuid": "4c5802e3-88ed-4e3e-929b-910aeb4c85f1", "name": "load_p1rlv13033_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1564c5f9-8b80-41b4-af09-2a55dee0718b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c32e1d70-5898-46d9-bdfe-474a13392868"}}}}, {"uuid": "ce96a1c1-4da1-4feb-ab24-94101677e52a", "name": "ac092c22-a341-4f4b-8b0e-06392057556b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "629c4abf-b246-4c2f-be64-fc45ce958904", "name": "2dca5672-682f-4a17-8c6a-9c7e92a4b7c3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ce96a1c1-4da1-4feb-ab24-94101677e52a"}}}]}, {"uuid": "ad7a7ba1-03a7-421c-af74-453a372d2ea2", "name": "load_p1rlv13033_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1564c5f9-8b80-41b4-af09-2a55dee0718b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "629c4abf-b246-4c2f-be64-fc45ce958904"}}}}, {"uuid": "c09b2358-e1d4-413e-b86c-89d5aeea06c6", "name": "709debc3-2c8b-473c-b17c-aa380a193726_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.074192704000552, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.129078804753558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a399b34-ceb0-4ca8-ab6b-fbeb5d6f11c7", "name": "2f4af060-e488-4b5c-bbdc-53115064906c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c09b2358-e1d4-413e-b86c-89d5aeea06c6"}}}]}, {"uuid": "8a1dd38f-312a-47da-905c-79698fc4f27c", "name": "load_p1rlv13034_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3b7bff1-90da-4ee2-8a0f-8e291a7e8ac8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a399b34-ceb0-4ca8-ab6b-fbeb5d6f11c7"}}}}, {"uuid": "223ca125-2a2e-42c1-a0f0-1828dd36ffba", "name": "5cbc8aa5-1d48-4762-9892-454566c93f99_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.074192704000552, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.129078804753558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a6972633-51d9-4e1e-be81-d289073144bd", "name": "4f0c4078-005c-4e05-a7c1-0bc96ee69bb0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "223ca125-2a2e-42c1-a0f0-1828dd36ffba"}}}]}, {"uuid": "fb379ee7-427c-476e-ac35-a702194e4e69", "name": "load_p1rlv13034_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3b7bff1-90da-4ee2-8a0f-8e291a7e8ac8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a6972633-51d9-4e1e-be81-d289073144bd"}}}}, {"uuid": "138ba538-6925-4490-b7f9-acb50c759789", "name": "3c7fb123-b99c-46f9-9eec-1cafe1d9f2e8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8791002615066037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24190904367644575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50264ea1-2130-4ac4-8d83-06f7624bd00e", "name": "44c01c96-1d1c-4b12-a737-fa38d53e233c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "138ba538-6925-4490-b7f9-acb50c759789"}}}]}, {"uuid": "349eb58c-b111-4f6d-92c2-159ecb9b146c", "name": "load_p1rlv13035_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6d309ef-b082-4022-a265-4891cdcd6db9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50264ea1-2130-4ac4-8d83-06f7624bd00e"}}}}, {"uuid": "b87dfe47-5295-4a04-b72a-5be002a781e1", "name": "6e915124-e0ea-436f-9543-a77188bab4cd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8791002615066037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24190904367644575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2fa5a665-5deb-467b-bc9f-e71f2bfdf9cf", "name": "bee7ab42-c47c-4c2f-8de9-ccab5a61c6bf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b87dfe47-5295-4a04-b72a-5be002a781e1"}}}]}, {"uuid": "e46287b6-7827-4592-b1f2-e687e6f7c00a", "name": "load_p1rlv13035_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6d309ef-b082-4022-a265-4891cdcd6db9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2fa5a665-5deb-467b-bc9f-e71f2bfdf9cf"}}}}, {"uuid": "b1401c39-ec75-4e7a-8caa-59de8c4e3727", "name": "7ec60f8a-d974-4b77-92e3-6cbdb06326b0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.131827489381682, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6495252596209705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "99ced9d6-782f-4da9-9093-b8b75d9454c2", "name": "19e9f87e-4cc7-4702-8545-744ffab5f522", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b1401c39-ec75-4e7a-8caa-59de8c4e3727"}}}]}, {"uuid": "74249f5e-7c0c-44ef-a2be-d9cadb9b8d06", "name": "load_p1rlv13036_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23aae8f1-8b9f-4453-9643-b49ffdc80889"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "99ced9d6-782f-4da9-9093-b8b75d9454c2"}}}}, {"uuid": "bb7a935e-ef3f-4259-9dce-2efb49419534", "name": "8451fc2b-9ede-464e-80ad-cec49e4e429f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.131827489381682, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6495252596209705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5a4776db-fe9d-4c72-b386-e630b5d5e0c9", "name": "c75f3183-02be-4b10-b581-a012f3bdcff2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bb7a935e-ef3f-4259-9dce-2efb49419534"}}}]}, {"uuid": "d0d08220-f82e-4813-9e86-d7f5cb6054e5", "name": "load_p1rlv13036_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23aae8f1-8b9f-4453-9643-b49ffdc80889"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5a4776db-fe9d-4c72-b386-e630b5d5e0c9"}}}}, {"uuid": "77d82711-d253-462f-9ce5-586d5710551c", "name": "d87b062f-7549-4bee-af82-d39450b08042_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5976710782342964, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7583664749710641, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "671b0544-3d59-4a1b-8ec2-057c16dd2d81", "name": "05306373-07f2-441b-a327-a67270b22e0d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "77d82711-d253-462f-9ce5-586d5710551c"}}}]}, {"uuid": "15c35e98-5054-4b11-b7b4-e8429f0b12fc", "name": "load_p1rlv13037_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f5d04aa-74fb-4d1a-ac91-6c01a56a94b5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "671b0544-3d59-4a1b-8ec2-057c16dd2d81"}}}}, {"uuid": "f31d5dca-c798-4cd4-b33b-6ef36ff34bc7", "name": "7dbc7a03-397e-4144-b496-f0c6fa124214_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5976710782342964, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7583664749710641, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a3e03fb2-566e-4710-a10c-7991ba3eeca0", "name": "4280b610-705e-4bf3-ba2f-30e609aa9084", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f31d5dca-c798-4cd4-b33b-6ef36ff34bc7"}}}]}, {"uuid": "1cd6f0e8-61a1-4056-9be8-650d4ddfb3c8", "name": "load_p1rlv13037_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f5d04aa-74fb-4d1a-ac91-6c01a56a94b5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a3e03fb2-566e-4710-a10c-7991ba3eeca0"}}}}, {"uuid": "79a2c1dd-04cb-47c4-aea3-5ad30f4dd768", "name": "635abd80-13c7-475c-af2d-43f4c81f0b5c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3798783675992279, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6151141774255103, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "74679bbb-a484-4253-95c3-882a57fe12a8", "name": "7a58bd99-3ac7-4f56-92ae-cdd643b0c927", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "79a2c1dd-04cb-47c4-aea3-5ad30f4dd768"}}}]}, {"uuid": "5502f1c8-b1b7-4e4b-a292-e5983d56926a", "name": "load_p1rlv13038_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a8b4502-31fd-4dce-8717-9860880075b4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "74679bbb-a484-4253-95c3-882a57fe12a8"}}}}, {"uuid": "8ad46779-2f5a-4b34-9123-594b28c7eef7", "name": "5dce28a7-bf93-405d-8b27-8d86926ff647_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3798783675992279, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6151141774255103, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fe24ccb4-a072-4c0e-9c69-7397187c0cf7", "name": "4477297e-dda0-42e2-bb36-9d0b9e1a7d1a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ad46779-2f5a-4b34-9123-594b28c7eef7"}}}]}, {"uuid": "b4ade9d1-a099-4144-8c8f-1313629a488b", "name": "load_p1rlv13038_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a8b4502-31fd-4dce-8717-9860880075b4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fe24ccb4-a072-4c0e-9c69-7397187c0cf7"}}}}, {"uuid": "f0d3a250-3125-47eb-beed-cb4d47fa06b4", "name": "177b4262-69d7-456e-a722-ddb895f56358_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9179777962446224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3481400399277513, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4bbd2f71-2995-4f3a-8fa8-bbdbc13b5f7b", "name": "e4ad0457-669c-4703-8935-20a525526720", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f0d3a250-3125-47eb-beed-cb4d47fa06b4"}}}]}, {"uuid": "8016b94a-61cd-4674-9c60-0410c68b8445", "name": "load_p1rlv13039_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34d43081-e4a3-4f1b-8b90-5965458452d0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4bbd2f71-2995-4f3a-8fa8-bbdbc13b5f7b"}}}}, {"uuid": "07e8ba08-4868-403a-8a82-8ca90c974837", "name": "b8559d4c-4ddd-4d69-af4d-82e49146b816_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9179777962446224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3481400399277513, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4d0f1690-75ce-4f79-9841-9acb4c42984c", "name": "5287314b-d1e0-4ade-b0b3-387b6329da2c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "07e8ba08-4868-403a-8a82-8ca90c974837"}}}]}, {"uuid": "b9f95b3b-f26e-4c6a-a080-a497e15d7e02", "name": "load_p1rlv13039_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34d43081-e4a3-4f1b-8b90-5965458452d0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4d0f1690-75ce-4f79-9841-9acb4c42984c"}}}}, {"uuid": "e29843ac-90b9-437c-9117-ccf066515291", "name": "29e3febd-4892-42b4-b287-c9ebfb418d08_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4464370236076721, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16599396793014964, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "03f4d81e-7c78-4db0-89f5-bee053df019a", "name": "d4430213-5d8e-4f92-af83-09a386b39a7e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e29843ac-90b9-437c-9117-ccf066515291"}}}]}, {"uuid": "c9b00953-9433-444e-a5c9-287baab06620", "name": "load_p1rlv13040_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6839f65-9d3b-4bd6-89a4-0c8feb33e98a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "03f4d81e-7c78-4db0-89f5-bee053df019a"}}}}, {"uuid": "2e0477a3-1ea7-4d91-81c7-3e83d4dea658", "name": "ecf11542-81c2-4406-a311-e724aa04cf7a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4464370236076721, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16599396793014964, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ddcc766b-ec42-4d26-bd83-7ddc9efec038", "name": "8083a4d1-79d3-4022-9268-102584301916", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2e0477a3-1ea7-4d91-81c7-3e83d4dea658"}}}]}, {"uuid": "09a05117-9020-4a21-8ab8-0ef14c99c774", "name": "load_p1rlv13040_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6839f65-9d3b-4bd6-89a4-0c8feb33e98a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ddcc766b-ec42-4d26-bd83-7ddc9efec038"}}}}, {"uuid": "9fd53137-bf5a-4f5f-a0b4-8276d87bb04e", "name": "6c17db69-bff2-4e56-a3c1-bb3723cd6918_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6434260893942235, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2588956175598443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3782e5b3-e7f7-4d7f-b4b4-58875e227199", "name": "f2e69ca8-aaf9-43be-9bee-272320ab0e80", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9fd53137-bf5a-4f5f-a0b4-8276d87bb04e"}}}]}, {"uuid": "1e04bc67-8ff5-44ca-8784-51571cb550f5", "name": "load_p1rlv13041_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60144ce1-d4d6-4725-b543-f881894356a5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3782e5b3-e7f7-4d7f-b4b4-58875e227199"}}}}, {"uuid": "30335b57-8e08-4154-960d-cdb9c5ede14d", "name": "6231824f-1b85-4d24-800d-f11202944c11_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6434260893942235, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2588956175598443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "119a9724-a20e-416d-809e-b714471622b9", "name": "184a31ea-7142-4290-9059-ff71e29618bd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "30335b57-8e08-4154-960d-cdb9c5ede14d"}}}]}, {"uuid": "d020a635-aab4-4f6b-83b6-a53650efb072", "name": "load_p1rlv13041_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60144ce1-d4d6-4725-b543-f881894356a5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "119a9724-a20e-416d-809e-b714471622b9"}}}}, {"uuid": "55db8cce-9446-48f3-8af9-62589b3bd742", "name": "b428e6d6-918d-4b4d-971d-7391125b8f9b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4148353854888571, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6393114443430603, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "294d20fe-cf8c-46f0-9f89-0657ecce2434", "name": "deaccebf-96cd-40dd-b573-7ca8f71d8aa1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "55db8cce-9446-48f3-8af9-62589b3bd742"}}}]}, {"uuid": "d794cf69-32cb-405e-aea3-c90086351290", "name": "load_p1rlv13042_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "296cd07e-c2e3-4031-abad-9c870a65105d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "294d20fe-cf8c-46f0-9f89-0657ecce2434"}}}}, {"uuid": "9eb257c7-77e7-41ba-b202-3ff32c0bae0f", "name": "32b13cdb-a6a7-4fa4-9149-82f44136ffe0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4148353854888571, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6393114443430603, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bd71a0f0-6c1d-48ed-bf4a-8de6a137936e", "name": "8f98108c-29bd-4c2f-ad46-00c13335eece", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9eb257c7-77e7-41ba-b202-3ff32c0bae0f"}}}]}, {"uuid": "3d035aed-8608-46c0-983e-7d889e4949f9", "name": "load_p1rlv13042_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "296cd07e-c2e3-4031-abad-9c870a65105d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bd71a0f0-6c1d-48ed-bf4a-8de6a137936e"}}}}, {"uuid": "425e2de3-13e4-4801-a064-4d6ab2e349ce", "name": "2aafb20a-ab3e-4270-8650-395ae93416dd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.478593979285423, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7308840963144931, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "291002f8-5c77-41b0-b8e0-60cd4dbfc1da", "name": "e96ce69e-4a0b-451e-beb7-464af7b99a7f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "425e2de3-13e4-4801-a064-4d6ab2e349ce"}}}]}, {"uuid": "f7547184-7196-4c0c-9432-e18539ec7017", "name": "load_p1rlv13513_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3243ca2f-a97e-4fbc-981d-85eded2e5e6b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "291002f8-5c77-41b0-b8e0-60cd4dbfc1da"}}}}, {"uuid": "fed2bcf4-ae62-4152-aa92-ec9cbf205825", "name": "f582a945-a569-495f-b213-31a28a011ac9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.478593979285423, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7308840963144931, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f12ac523-0ead-4cbf-969c-b26ceaaeec58", "name": "eb431eed-b218-4601-9fa7-f4a8dabafcff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fed2bcf4-ae62-4152-aa92-ec9cbf205825"}}}]}, {"uuid": "737befe8-c05e-4ae8-baf6-f2e2a1d20f28", "name": "load_p1rlv13513_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3243ca2f-a97e-4fbc-981d-85eded2e5e6b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f12ac523-0ead-4cbf-969c-b26ceaaeec58"}}}}, {"uuid": "1a5b8ef6-4d4b-4207-aaae-0b8a6562ae2c", "name": "e127eac9-8755-4774-a29d-89f9e6b418a0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.516258392707745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.82351986644914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "03330f10-9cb3-42e2-aef8-e02084fc5dec", "name": "a8790ecc-0157-4088-82d4-7aa10c681ebb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1a5b8ef6-4d4b-4207-aaae-0b8a6562ae2c"}}}]}, {"uuid": "059c3995-844d-453c-932d-52647f7dbc4c", "name": "load_p1rlv13789_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47a7519a-b550-41e6-99e3-c2115db425fe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "03330f10-9cb3-42e2-aef8-e02084fc5dec"}}}}, {"uuid": "2e22c9e7-f048-46f8-bc69-5861cfd05527", "name": "8c2a521a-38cb-4686-8fa9-386999634546_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.516258392707745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.82351986644914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eae585db-5e8d-4d76-8203-27d0420f79b4", "name": "188cd438-df8d-4b24-b92d-fddfbb0a2ebe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2e22c9e7-f048-46f8-bc69-5861cfd05527"}}}]}, {"uuid": "5cf01015-ea31-4da1-939a-778efe5c2762", "name": "load_p1rlv13789_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47a7519a-b550-41e6-99e3-c2115db425fe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eae585db-5e8d-4d76-8203-27d0420f79b4"}}}}, {"uuid": "15995836-e2ba-4cf9-b118-fff27f395444", "name": "a6f8ebb6-0854-4d92-9356-401305b2a257_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3786182488338723, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5359363058124609, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6151c915-f4c7-4240-b24d-ee4967125fff", "name": "08169670-c1b9-4102-9b44-fc13d2303d0c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "15995836-e2ba-4cf9-b118-fff27f395444"}}}]}, {"uuid": "4e713549-1fcf-420c-ba99-1a57feebc8e5", "name": "load_p1rlv13791_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "251f270f-4238-4fe6-8ab3-f884fca7a42d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6151c915-f4c7-4240-b24d-ee4967125fff"}}}}, {"uuid": "7dfb398c-2767-42a5-a503-e4c1a92dab37", "name": "787f56e7-2686-4704-aafa-30bc043d4c7d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3786182488338723, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5359363058124609, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "01d1aabe-0a01-4e59-a48f-7c981a2fdc1a", "name": "22519096-b6e1-40e2-975d-736497e787ed", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7dfb398c-2767-42a5-a503-e4c1a92dab37"}}}]}, {"uuid": "db355cce-248a-4b61-815d-b564ae9f0424", "name": "load_p1rlv13791_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "251f270f-4238-4fe6-8ab3-f884fca7a42d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "01d1aabe-0a01-4e59-a48f-7c981a2fdc1a"}}}}, {"uuid": "5b2c074c-c20e-4eab-b9a8-e92b48974001", "name": "8fde2c8d-0b7d-43c0-b5e3-9724c9e6f07c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4950137537296666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31506625700854357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5c88bd25-3fea-4b53-a5c3-29d534c2286e", "name": "86a0e8fc-47a8-451c-b70d-2cb2c944eb6e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b2c074c-c20e-4eab-b9a8-e92b48974001"}}}]}, {"uuid": "2bb93d01-77c6-4fb0-b5b0-918cc6184ea8", "name": "load_p1rlv13796_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94ac9254-cdbf-4864-b22b-bcfb0a827700"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5c88bd25-3fea-4b53-a5c3-29d534c2286e"}}}}, {"uuid": "eb63e254-b796-476a-afba-e8ebb47b74e4", "name": "cf5e3c94-b0f7-462e-a355-b258ae53f695_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4950137537296666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31506625700854357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "23da9e2b-d468-4008-b47f-d63d8c87dadb", "name": "6a1fe7ff-ccbd-46ac-b9ad-285f127c3344", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eb63e254-b796-476a-afba-e8ebb47b74e4"}}}]}, {"uuid": "2f75fc92-6b34-4785-8154-8f0b31b77142", "name": "load_p1rlv13796_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94ac9254-cdbf-4864-b22b-bcfb0a827700"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "23da9e2b-d468-4008-b47f-d63d8c87dadb"}}}}, {"uuid": "62825484-a85f-4497-9f3f-aa09f9016fe1", "name": "52fad3e9-45c9-4056-a73b-cb0e42e846c1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.008167500419157, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.871384812064858, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "40ad2075-2f27-43f9-bf26-24398179c740", "name": "15638478-3799-4f8d-a195-0cf7ad60607a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "62825484-a85f-4497-9f3f-aa09f9016fe1"}}}]}, {"uuid": "8e3b48bc-f743-4918-a2a8-d5c73997b5a5", "name": "load_p1rlv13801_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "accec892-a236-462d-b714-1178393ec992"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "40ad2075-2f27-43f9-bf26-24398179c740"}}}}, {"uuid": "da810e7f-f506-45e9-913d-f97a58abd11e", "name": "648f7673-2b7c-4917-9c63-f95e75196436_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.008167500419157, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.871384812064858, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1f8ea155-e6d1-4317-8ea6-a50f177cd91d", "name": "6e917f1f-4044-42e1-adfd-a0279c5d3d2d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "da810e7f-f506-45e9-913d-f97a58abd11e"}}}]}, {"uuid": "a0320d1d-20ae-462f-9746-521cd612a5bd", "name": "load_p1rlv13801_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "accec892-a236-462d-b714-1178393ec992"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1f8ea155-e6d1-4317-8ea6-a50f177cd91d"}}}}, {"uuid": "888affa1-c032-49bf-b439-d454732e868e", "name": "aa1d1c01-f032-40a4-85be-478812f1eec9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7055277650263714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24030088917661724, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f3390525-aa36-4b5e-b5c7-05b031722646", "name": "ac90927c-2c18-439c-9388-1849753638b9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "888affa1-c032-49bf-b439-d454732e868e"}}}]}, {"uuid": "0f26d234-dc12-4b26-9669-c0cc9f06d569", "name": "load_p1rlv13807_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c26fba44-3b81-47de-81e6-522f2daf0534"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f3390525-aa36-4b5e-b5c7-05b031722646"}}}}, {"uuid": "e816eb48-5381-4aa3-8477-15717e4343b5", "name": "3f3c2bee-1196-4b7f-aa9a-6b7f6163e03a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7055277650263714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24030088917661724, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "67b6d902-8b82-47cf-a989-f252d66071a4", "name": "4f177047-2b91-4fcc-aee1-b7321b7be182", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e816eb48-5381-4aa3-8477-15717e4343b5"}}}]}, {"uuid": "6d8a4cc7-ad2d-4b8e-9bdf-c6ca602aad0c", "name": "load_p1rlv13807_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c26fba44-3b81-47de-81e6-522f2daf0534"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "67b6d902-8b82-47cf-a989-f252d66071a4"}}}}, {"uuid": "d1cf8902-36ff-4259-8e06-9c26e6496790", "name": "4d637426-9411-4538-9c9c-90c7616f7121_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5041010955030301, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21577690333785765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4459f193-4f92-46a4-8eed-add2c2837094", "name": "95fb1d20-7bb6-49df-901a-9410ab8b79e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d1cf8902-36ff-4259-8e06-9c26e6496790"}}}]}, {"uuid": "3e004b64-3af9-48f6-9dfd-fc8b13172d45", "name": "load_p1rlv13808_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c795ac7-3b49-4158-996d-2fb1f0337847"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4459f193-4f92-46a4-8eed-add2c2837094"}}}}, {"uuid": "2f4c2dc2-6bdb-4037-90cb-691a2702b98b", "name": "958bc998-f198-4634-9716-9c72eefb2a1c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5041010955030301, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21577690333785765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "27270979-b92b-4d35-af3a-2c0e04df552b", "name": "0c08438e-daba-4da3-a5dc-db54fa184471", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2f4c2dc2-6bdb-4037-90cb-691a2702b98b"}}}]}, {"uuid": "74ab9452-4a60-4e6f-8072-464d74ee30df", "name": "load_p1rlv13808_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c795ac7-3b49-4158-996d-2fb1f0337847"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "27270979-b92b-4d35-af3a-2c0e04df552b"}}}}, {"uuid": "09eac509-8dac-41fe-9bce-64d8745425df", "name": "7dd53474-539f-4945-ac4c-c735c42112a5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0716753053645807, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8046017922971841, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "595de68a-b010-43ba-b21e-cc78f49bf48c", "name": "f02bea0f-dbc3-4422-a398-93888ea0def0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "09eac509-8dac-41fe-9bce-64d8745425df"}}}]}, {"uuid": "5c7db3cf-10d4-4267-8217-45a53afc7161", "name": "load_p1rlv13809_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "687996da-ab03-4544-b0d9-b79b8ac88e95"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "595de68a-b010-43ba-b21e-cc78f49bf48c"}}}}, {"uuid": "e5a9e2ec-ffef-4651-b51a-9f5316c82fb3", "name": "d7ece7d1-ce61-48ea-9df6-aa24014abecc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0716753053645807, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8046017922971841, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "efe80323-ab9b-4e01-815f-7fd0ce6c61df", "name": "92358e67-308f-4f32-b27a-e88559370266", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e5a9e2ec-ffef-4651-b51a-9f5316c82fb3"}}}]}, {"uuid": "0f2cf445-d144-43b5-80e0-38fd27f20829", "name": "load_p1rlv13809_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "687996da-ab03-4544-b0d9-b79b8ac88e95"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "efe80323-ab9b-4e01-815f-7fd0ce6c61df"}}}}, {"uuid": "764a156c-e82c-4978-9206-f52ce77f1f99", "name": "c1836a03-add8-4694-8d66-c2a6ed431151_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2437684685157903, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09956111056866535, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ae3347f6-7775-4433-814b-7ba9513e963e", "name": "bd38cf53-e217-4b92-a4c4-d1ffe15199df", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "764a156c-e82c-4978-9206-f52ce77f1f99"}}}]}, {"uuid": "55eed416-e9d9-4d58-8026-22b2f3f7cfe3", "name": "load_p1rlv13810_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab29ca66-d59b-4aa6-b5f6-165add0bc331"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ae3347f6-7775-4433-814b-7ba9513e963e"}}}}, {"uuid": "5cb79924-30c9-43e2-9a96-729fd0ac694c", "name": "3debea35-c388-41e2-83e2-aa90977b6cc3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2437684685157903, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09956111056866535, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2e0910b7-f02c-4d0e-bf15-f0b81921172f", "name": "f99681c6-3e7c-4c69-85c3-db72b795048f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5cb79924-30c9-43e2-9a96-729fd0ac694c"}}}]}, {"uuid": "8c2da7f0-f23d-49e5-a56f-820d68cb01a9", "name": "load_p1rlv13810_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab29ca66-d59b-4aa6-b5f6-165add0bc331"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2e0910b7-f02c-4d0e-bf15-f0b81921172f"}}}}, {"uuid": "8982f43c-2ab5-484c-91cd-8e23d4654b47", "name": "072f3713-115a-432e-b689-83fa9f6ad36d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.291842017688742, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7877197601951852, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0e13e8a7-69f7-4384-b6c2-6f9ab0821da4", "name": "a275ccd5-d06c-427c-b582-d3fa7d408111", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8982f43c-2ab5-484c-91cd-8e23d4654b47"}}}]}, {"uuid": "77fbe0a1-4002-4304-b6e3-b6284061bd2f", "name": "load_p1rlv13814_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028d5ead-7c34-400b-bcc1-c4d706c965d3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0e13e8a7-69f7-4384-b6c2-6f9ab0821da4"}}}}, {"uuid": "9c01f881-0f25-4d6f-a0dd-993098bd49f3", "name": "f2d86489-1f92-4a87-bfff-a752fdc6953b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.291842017688742, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7877197601951852, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d84a97b2-613d-4893-b775-76dcb6d72baf", "name": "beb70e77-2905-4532-b661-ae7947ab1dd9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9c01f881-0f25-4d6f-a0dd-993098bd49f3"}}}]}, {"uuid": "725fc8ff-fe31-4c43-a721-a77c74959288", "name": "load_p1rlv13814_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028d5ead-7c34-400b-bcc1-c4d706c965d3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d84a97b2-613d-4893-b775-76dcb6d72baf"}}}}, {"uuid": "9485e0ab-76b3-4249-95c6-c9694fbcc55f", "name": "186fb67b-61b4-4e51-85e1-ea65bdfd5178_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5478654763148745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5646840796232575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82a2547d-e285-4e42-9a0d-ba17743e95e5", "name": "c4052cf7-690b-460a-9695-67409665f911", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9485e0ab-76b3-4249-95c6-c9694fbcc55f"}}}]}, {"uuid": "61cacffc-8e4f-446d-9a8a-931f9727a422", "name": "load_p1rlv13815_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99957459-46a6-4b2b-9813-69b11ca7dad1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "82a2547d-e285-4e42-9a0d-ba17743e95e5"}}}}, {"uuid": "66b8279c-9e1c-45f4-b507-e46cf979f5c6", "name": "191437de-ee79-45c6-be63-1bbce4377cfc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5478654763148745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5646840796232575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6ef4d2cf-ba8f-4ed5-8ce4-e3056b1156af", "name": "c7fff845-744f-4630-aa26-cd67a5961399", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "66b8279c-9e1c-45f4-b507-e46cf979f5c6"}}}]}, {"uuid": "76a08ec6-32a3-435c-9c52-2118ff199523", "name": "load_p1rlv13815_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99957459-46a6-4b2b-9813-69b11ca7dad1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6ef4d2cf-ba8f-4ed5-8ce4-e3056b1156af"}}}}, {"uuid": "a17c41d6-24e9-4b26-b9f9-de67964bb309", "name": "874e3fbd-6b4d-407a-8383-51ddc0d9aef7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0085854932437286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7150296414254909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "81850b27-a9b8-4fab-b10e-81a89ac0bc87", "name": "fc960aa0-6058-4889-b9e8-5a07b2878577", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a17c41d6-24e9-4b26-b9f9-de67964bb309"}}}]}, {"uuid": "f8444c20-8eea-40ac-a488-93a9711e5ff0", "name": "load_p1rlv13817_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e96bcc5b-07c5-4289-aec4-0224395c5e8a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "81850b27-a9b8-4fab-b10e-81a89ac0bc87"}}}}, {"uuid": "d54c2be7-a14b-4aef-8853-4acd41e72c47", "name": "3c0522c5-f6f6-4b47-a464-522778742137_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0085854932437286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7150296414254909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "12e364e5-acfd-4e1d-89f6-21c9acd3d848", "name": "d620051e-a9a4-445e-aa26-8eca2cc48ec2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d54c2be7-a14b-4aef-8853-4acd41e72c47"}}}]}, {"uuid": "010ca500-2acf-4ce6-a039-674b272f9de8", "name": "load_p1rlv13817_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e96bcc5b-07c5-4289-aec4-0224395c5e8a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "12e364e5-acfd-4e1d-89f6-21c9acd3d848"}}}}, {"uuid": "4ed34c37-e2e9-4a65-a903-8a7caf11552c", "name": "78d7d066-06b1-4597-8e7d-fbf0e4036139_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1381537134701794, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42848704523913217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c0b7b5ac-4a0b-49c2-92c7-27cadd156772", "name": "aebf1b77-f7cf-43a9-a950-21464c55fb9e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4ed34c37-e2e9-4a65-a903-8a7caf11552c"}}}]}, {"uuid": "a8a6ea27-b4a4-4d06-8c4f-af8f1127daad", "name": "load_p1rlv13819_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36c12a74-a2ca-439a-a69f-308dd5cb1207"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c0b7b5ac-4a0b-49c2-92c7-27cadd156772"}}}}, {"uuid": "781fe3f1-6b6c-48b9-abd9-77d5b7369aae", "name": "5f1443a2-975b-4cb0-86c4-0b677d3a55db_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1381537134701794, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42848704523913217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "35ede9f1-60a6-4d8d-9701-723de6433418", "name": "efef0562-da88-4e42-aade-749922d559fa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "781fe3f1-6b6c-48b9-abd9-77d5b7369aae"}}}]}, {"uuid": "109422e2-02b7-4e4c-a09f-06afab81a341", "name": "load_p1rlv13819_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36c12a74-a2ca-439a-a69f-308dd5cb1207"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "35ede9f1-60a6-4d8d-9701-723de6433418"}}}}, {"uuid": "66d4d596-e4c7-4a54-a4e6-38df808f0693", "name": "14e258f3-02bd-4e24-95a2-41a1a66bfdb7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.3612796720379805, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.3972907909814523, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a31f4fb0-d83d-4ad1-86a9-4cfdf5a4bee9", "name": "9b2c0e73-1ff0-4035-bd34-92cd7d49c9be", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "66d4d596-e4c7-4a54-a4e6-38df808f0693"}}}]}, {"uuid": "85c9ad07-5dc3-47c3-aa58-1945480e5aff", "name": "load_p1rlv13820_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a2caa70b-9143-4676-834b-bfc7cb41330c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a31f4fb0-d83d-4ad1-86a9-4cfdf5a4bee9"}}}}, {"uuid": "b927f7b1-4142-4df3-a0fa-95a333a7982f", "name": "2a448f2a-f40c-4c5d-bd9f-5e1dc505e62d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.3612796720379805, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.3972907909814523, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bc7e8ec9-7648-41d1-8858-e4c8ddaaef33", "name": "98b412f3-26ab-4cfa-a65f-55021acba615", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b927f7b1-4142-4df3-a0fa-95a333a7982f"}}}]}, {"uuid": "d09ba371-5421-4487-90ee-5e8bfd642999", "name": "load_p1rlv13820_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a2caa70b-9143-4676-834b-bfc7cb41330c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bc7e8ec9-7648-41d1-8858-e4c8ddaaef33"}}}}, {"uuid": "ad98ac11-5d4c-4742-b631-47f8b8ad5445", "name": "ab8854ef-b22e-4714-8819-41beee60bb75_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.635130525488038, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.332876746135676, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a8dbac4e-81f6-40fa-8b95-8d36357946af", "name": "4d40fbdc-7093-474b-be43-a3bb70b4d5ff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ad98ac11-5d4c-4742-b631-47f8b8ad5445"}}}]}, {"uuid": "d501dc5e-ac3c-457d-9bc2-ea5a144144eb", "name": "load_p1rlv13821_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66e6c732-919a-4851-9f76-5580ea71669d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a8dbac4e-81f6-40fa-8b95-8d36357946af"}}}}, {"uuid": "8f0e7ca1-035f-45eb-b40d-b347ef767d4f", "name": "ca440c4c-f25c-4309-98c9-edf583c1ec98_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.635130525488038, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.332876746135676, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "57e80d64-eb9a-4869-acfa-665c994e1148", "name": "8ae6d28a-801a-45b2-8390-e0422e4f9124", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8f0e7ca1-035f-45eb-b40d-b347ef767d4f"}}}]}, {"uuid": "a78a4b78-fc95-4288-bc8f-85602712d6c7", "name": "load_p1rlv13821_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66e6c732-919a-4851-9f76-5580ea71669d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "57e80d64-eb9a-4869-acfa-665c994e1148"}}}}, {"uuid": "355253ea-407d-4eb0-9b8d-c609e3b8b8cc", "name": "6ebb2d5e-69fc-474d-bda3-d3b44a463d0c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7812856221781264, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.29493523962554685, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ff2e9217-8807-434d-a450-744efe345e72", "name": "3752c325-d5c2-4d40-8e38-7b04fc71177a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "355253ea-407d-4eb0-9b8d-c609e3b8b8cc"}}}]}, {"uuid": "68efcac0-34fe-4dd9-a0e2-fe0c3d757d94", "name": "load_p1rlv13822_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ade9991-a857-4619-8094-c18f824aaeb9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ff2e9217-8807-434d-a450-744efe345e72"}}}}, {"uuid": "6bd0f62f-8edf-4810-99be-e798cac24cf2", "name": "356dfa36-fd2a-4a57-8e5d-1a9549308602_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7812856221781264, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.29493523962554685, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6407febc-5c2c-4ba9-803c-40af9378c220", "name": "32c9cd48-906e-4915-b516-d48f6bb09d2c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6bd0f62f-8edf-4810-99be-e798cac24cf2"}}}]}, {"uuid": "4da4f5d5-66ee-4fcb-aea2-ce75b8f24a11", "name": "load_p1rlv13822_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ade9991-a857-4619-8094-c18f824aaeb9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6407febc-5c2c-4ba9-803c-40af9378c220"}}}}, {"uuid": "46b7186f-23aa-404f-89fe-b1da22b8988b", "name": "71a40a7d-0b07-4707-9fc8-7453aa248bbb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1222862909492073, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34523553920221683, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c03ecb1d-7a8d-432a-87f1-649a7a2c0bd8", "name": "9143989a-51bb-4e7f-bbaf-2e6f00feef4c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "46b7186f-23aa-404f-89fe-b1da22b8988b"}}}]}, {"uuid": "b18c5017-b58a-4d8e-99df-186b1dba584a", "name": "load_p1rlv13823_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0ca6e47-afec-4d61-885a-e38176b32444"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c03ecb1d-7a8d-432a-87f1-649a7a2c0bd8"}}}}, {"uuid": "bc9b1700-bb49-4cb1-ba5d-5f80b5313fde", "name": "19de82c2-7a92-46ca-bc78-b9aa550e0efc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1222862909492073, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34523553920221683, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "481ac917-3cd4-4104-bab6-aad3b2b02a90", "name": "1612e353-bc27-4924-95ca-d05df4a50023", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bc9b1700-bb49-4cb1-ba5d-5f80b5313fde"}}}]}, {"uuid": "96ad3f28-9350-4e7f-abbc-430e1bb63746", "name": "load_p1rlv13823_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0ca6e47-afec-4d61-885a-e38176b32444"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "481ac917-3cd4-4104-bab6-aad3b2b02a90"}}}}, {"uuid": "79f3753a-7149-4157-b5e4-68982efaa8ca", "name": "093cd540-9bbc-4ee5-a1e0-2e2ef4a34478_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0669054080609572, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7994840804155045, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f2b10606-cf40-4f5e-bb6b-1183f05e041e", "name": "acb548ef-de03-45bf-bf02-d36ee7faa744", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "79f3753a-7149-4157-b5e4-68982efaa8ca"}}}]}, {"uuid": "9c321716-f7ca-445e-b012-ab6f30c94193", "name": "load_p1rlv15585_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17bf6d8f-8215-4294-b921-cc3e34476f1e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f2b10606-cf40-4f5e-bb6b-1183f05e041e"}}}}, {"uuid": "e0082e7d-626d-4758-b35b-36b85a8bff3c", "name": "35e9eec9-3f85-4855-bfa4-52cf1d9cba4e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0669054080609572, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7994840804155045, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1edba1d9-3282-4395-a1ac-8fd917612c27", "name": "d0a1ea2f-1355-4c4d-878f-841f1e375af0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e0082e7d-626d-4758-b35b-36b85a8bff3c"}}}]}, {"uuid": "1cc5b71c-3d4d-4387-9b29-4375835ef133", "name": "load_p1rlv15585_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17bf6d8f-8215-4294-b921-cc3e34476f1e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1edba1d9-3282-4395-a1ac-8fd917612c27"}}}}, {"uuid": "54f40cb1-f555-4f22-9b86-3ed586a0c349", "name": "c29e80eb-35b5-42ba-9bbe-89cbf4d903da_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5604078463831266, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5882122505209306, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "059e1513-1fe8-44d2-9898-82d08b870b03", "name": "9b67a0dd-e06b-428b-bdf8-4ccfb9e0750b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "54f40cb1-f555-4f22-9b86-3ed586a0c349"}}}]}, {"uuid": "73b6699e-ca8b-43e4-b03e-082e1cc0e819", "name": "load_p1rlv15590_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef2a4478-4644-4bd3-9548-ab1d0be338b5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "059e1513-1fe8-44d2-9898-82d08b870b03"}}}}, {"uuid": "0e336d83-0a40-46ee-b0c8-a82812cf81a4", "name": "43ad8f4c-662d-4fb5-a5f9-a48dbaa271a7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5604078463831266, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5882122505209306, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2461bc70-0a3e-46b4-ad45-4297c1165017", "name": "4bf42159-d677-40ea-8cc5-b5591969ab5d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0e336d83-0a40-46ee-b0c8-a82812cf81a4"}}}]}, {"uuid": "7e04a4d6-9633-4b85-8c34-9d443e029fd6", "name": "load_p1rlv15590_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef2a4478-4644-4bd3-9548-ab1d0be338b5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2461bc70-0a3e-46b4-ad45-4297c1165017"}}}}, {"uuid": "f944fca3-773c-4d7f-8b9c-9c768d5194b2", "name": "9a7d04aa-5710-4fb1-bafb-40d7ed8d7695_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.478593979285423, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7308840963144931, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "17274469-c61a-4e5b-9160-1467f85cf8cf", "name": "931f85c8-2769-4c0e-9348-bb5827062179", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f944fca3-773c-4d7f-8b9c-9c768d5194b2"}}}]}, {"uuid": "a5d49acc-5c50-4480-842c-23e9d28d87bf", "name": "load_p1rlv15591_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c04c9ad1-4277-47de-9cec-9ce86e17b4f1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "17274469-c61a-4e5b-9160-1467f85cf8cf"}}}}, {"uuid": "0a49d7eb-c234-4ada-b568-908ac6cb8e4a", "name": "666b1c83-9b0c-4428-a813-b474316ec8f4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.478593979285423, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7308840963144931, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4148c82d-646b-4921-bc7a-6c5bf7f63ec7", "name": "c7b85c79-340b-4ef3-9ed6-191a807611d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0a49d7eb-c234-4ada-b568-908ac6cb8e4a"}}}]}, {"uuid": "ac304791-72f7-4e03-8c61-3aba5baa1c72", "name": "load_p1rlv15591_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c04c9ad1-4277-47de-9cec-9ce86e17b4f1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4148c82d-646b-4921-bc7a-6c5bf7f63ec7"}}}}, {"uuid": "d31de800-7b5e-4b79-8a91-b2ccf0116ef6", "name": "e1eb7567-068e-4f7f-9e16-f511bd93e9f6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.948793644259809, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2896354077041818, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2975b96e-edfa-4ad7-84f0-03367cdabd07", "name": "5e49d6ea-6260-48be-91dd-179c0bc5b5b4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d31de800-7b5e-4b79-8a91-b2ccf0116ef6"}}}]}, {"uuid": "3a9ac693-9be6-498c-ac0d-72e6efaca5cf", "name": "load_p1rlv15595_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "629e2259-2a59-4b20-b8bf-7b3b2c4a48f9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2975b96e-edfa-4ad7-84f0-03367cdabd07"}}}}, {"uuid": "ee77396d-e109-43f4-9c40-6bf91f21ab36", "name": "261e2ad9-5239-44cc-8678-56fd57346b98_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.948793644259809, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2896354077041818, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eeb2ed11-f664-42aa-9324-d0f09b516145", "name": "b870489c-6cb3-4057-80e7-9cd9924ce7b2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ee77396d-e109-43f4-9c40-6bf91f21ab36"}}}]}, {"uuid": "176c85cb-d0d6-4c48-b671-648e88751c24", "name": "load_p1rlv15595_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "629e2259-2a59-4b20-b8bf-7b3b2c4a48f9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eeb2ed11-f664-42aa-9324-d0f09b516145"}}}}, {"uuid": "a0cb21e7-4b27-494e-bb3c-081400c00bc8", "name": "7667dd6b-9cfc-4f76-a0e9-130988b27064_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6211116916449642, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3778136238343289, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "71b9d2b3-acfd-4691-9f5f-adf773dd27d8", "name": "f26b0db5-6978-4f0a-a69e-fc122b3225bb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a0cb21e7-4b27-494e-bb3c-081400c00bc8"}}}]}, {"uuid": "bf2cc4c4-abae-4bad-9ca5-5ea2c5f8bbfc", "name": "load_p1rlv15598_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "af6b7d1b-896f-44ac-8038-748c74507253"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "71b9d2b3-acfd-4691-9f5f-adf773dd27d8"}}}}, {"uuid": "81dfd6e0-dbbb-41cf-81aa-9fb817150959", "name": "8b6a8b1c-53fd-4091-9649-2bfb2059685f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6211116916449642, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3778136238343289, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10db06a2-89ef-4e34-9cbb-f016a6dc8746", "name": "60ca488e-a6f0-43aa-9158-5c4134a82e18", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "81dfd6e0-dbbb-41cf-81aa-9fb817150959"}}}]}, {"uuid": "ab44ad34-bc95-4072-8e13-b0f8a2f34e93", "name": "load_p1rlv15598_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "af6b7d1b-896f-44ac-8038-748c74507253"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10db06a2-89ef-4e34-9cbb-f016a6dc8746"}}}}, {"uuid": "de0aecc7-b36d-4357-a63e-d9785ef9bd9e", "name": "e8956775-6849-4664-a683-f47391afb338_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6626119076444468, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.30654437548368263, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "be09f5f7-fed8-43b1-b26d-c8aec95e842a", "name": "84b3e339-af7c-41c6-b51d-3c1a69a7ecf2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "de0aecc7-b36d-4357-a63e-d9785ef9bd9e"}}}]}, {"uuid": "62789cd6-098e-4f7b-8814-72c8eb1034f7", "name": "load_p1rlv15599_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ae1bbf1-459f-4346-b525-393b7d1dc958"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "be09f5f7-fed8-43b1-b26d-c8aec95e842a"}}}}, {"uuid": "8f1f6184-fcb4-4f3a-8e3f-f9f39682703d", "name": "a0dec14d-ea6f-4bfe-8b30-760d5443cf0a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6626119076444468, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.30654437548368263, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "01885877-0367-499f-83f1-52c8a24fec2e", "name": "ebec3fea-a57f-42a2-ab97-b2a72764c4a9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8f1f6184-fcb4-4f3a-8e3f-f9f39682703d"}}}]}, {"uuid": "ee2fb437-7c18-43e0-a778-72bbb4ecaf9d", "name": "load_p1rlv15599_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ae1bbf1-459f-4346-b525-393b7d1dc958"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "01885877-0367-499f-83f1-52c8a24fec2e"}}}}, {"uuid": "e56b29a0-5f6f-4023-90d3-cfe2d5ef010b", "name": "168abaa0-2fb2-4799-a684-581c86f41a4f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5348201699646123, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21241824123648728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b5869fd3-257a-473f-b5d2-282d0b26d37c", "name": "40231832-f936-4a1e-8d34-f03562bbd8aa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e56b29a0-5f6f-4023-90d3-cfe2d5ef010b"}}}]}, {"uuid": "5c5f9ae0-221c-48b9-86c2-5f669de204a3", "name": "load_p1rlv15604_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95b45d46-b7e7-46e2-98d9-5034e2fa0a17"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b5869fd3-257a-473f-b5d2-282d0b26d37c"}}}}, {"uuid": "87de1d2f-cb99-4681-b480-a5253cd1986a", "name": "0ee55c44-0e48-4ead-8915-bd8a7ece68c4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5348201699646123, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21241824123648728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "524946ab-d09d-4447-8882-4767d74df004", "name": "a25383b2-0b5e-4385-a110-4074e5c8c5b4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "87de1d2f-cb99-4681-b480-a5253cd1986a"}}}]}, {"uuid": "3fee4c6e-4a64-4574-bd57-4bfcba0420d2", "name": "load_p1rlv15604_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95b45d46-b7e7-46e2-98d9-5034e2fa0a17"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "524946ab-d09d-4447-8882-4767d74df004"}}}}, {"uuid": "662ce46f-3407-471f-a2d1-7adef310daae", "name": "b17569db-16f1-46a4-82ef-66575d501701_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7411160800233395, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1601349573814363, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bfcb1024-72a9-490c-8f55-ccb820aca246", "name": "0d318d79-dcc9-40fd-a6ea-08c8a1ae04be", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "662ce46f-3407-471f-a2d1-7adef310daae"}}}]}, {"uuid": "cb8b01f1-db5f-4676-8d79-e4ccbf10fae9", "name": "load_p1rlv15605_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcbee2ff-bf73-4834-bc3c-46fa0cfcad7c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bfcb1024-72a9-490c-8f55-ccb820aca246"}}}}, {"uuid": "205aab40-1007-48e6-83a7-4510a1f97591", "name": "8175f2e1-ebdb-424a-a3c2-2caf2256e5fc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7411160800233395, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1601349573814363, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1dedfe32-2b65-4f1a-a054-b0de2a8836b9", "name": "1a392444-0d33-46c5-8e8d-cbd0f3964e7c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "205aab40-1007-48e6-83a7-4510a1f97591"}}}]}, {"uuid": "3864a69d-0240-4a2a-83cd-4d7e71841b86", "name": "load_p1rlv15605_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcbee2ff-bf73-4834-bc3c-46fa0cfcad7c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1dedfe32-2b65-4f1a-a054-b0de2a8836b9"}}}}, {"uuid": "828cc09a-fe2a-4ee1-9a72-a9b480f38b6e", "name": "fa3d92fd-97ad-40ff-9d8f-f84c88373f5c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1813646779377422, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20173832232537287, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fc35cab6-95e9-44c5-b70f-05b92b4d412d", "name": "fc0295ec-7b0d-4e55-bd2d-8d88ed0eabb7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "828cc09a-fe2a-4ee1-9a72-a9b480f38b6e"}}}]}, {"uuid": "f3c39724-bce3-49eb-a332-5055b6ee129b", "name": "load_p1rlv15608_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13d6bce6-9066-43a1-b2b6-00a2a4398958"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fc35cab6-95e9-44c5-b70f-05b92b4d412d"}}}}, {"uuid": "c83a74b2-d475-4147-808e-0dccf1a9a3b4", "name": "3d38d38b-5d2d-4970-b5e3-886dde0671c1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1813646779377422, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20173832232537287, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "002ae075-c151-4cc2-9fb9-85a86472f2f9", "name": "a87fb5a0-40b5-4eee-b194-d1f698ed5f37", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c83a74b2-d475-4147-808e-0dccf1a9a3b4"}}}]}, {"uuid": "9055524e-3ac0-4565-b9cd-93f4591fcec6", "name": "load_p1rlv15608_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13d6bce6-9066-43a1-b2b6-00a2a4398958"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "002ae075-c151-4cc2-9fb9-85a86472f2f9"}}}}, {"uuid": "4212ded5-f581-4764-a59d-65fa5f2a198c", "name": "5d907014-cc5a-402a-8bf4-c18f781cafa2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.046232297850773, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7285366000251032, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "46d7587a-7dad-42d6-b692-57ee52c08570", "name": "443cdf73-68ba-4425-9e0d-2be0e1cf4df1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4212ded5-f581-4764-a59d-65fa5f2a198c"}}}]}, {"uuid": "e5249452-bd5d-4408-aa97-f2be5b14b2f0", "name": "load_p1rlv15616_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43ed408e-35e2-4bca-9060-a0c211aea1e7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "46d7587a-7dad-42d6-b692-57ee52c08570"}}}}, {"uuid": "0384f4b8-3dd0-4a01-b3f9-5c3a03a67deb", "name": "82d07e53-05b9-4605-8c73-35c475f1fa40_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.046232297850773, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7285366000251032, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "acb2dbdb-58a4-4de6-9fc8-e8efcb0a1324", "name": "a2877474-25d5-4c42-a694-63c46491a769", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0384f4b8-3dd0-4a01-b3f9-5c3a03a67deb"}}}]}, {"uuid": "a44343d7-5bcb-4693-96f3-3ad2aa61a044", "name": "load_p1rlv15616_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43ed408e-35e2-4bca-9060-a0c211aea1e7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "acb2dbdb-58a4-4de6-9fc8-e8efcb0a1324"}}}}, {"uuid": "eabfde0e-54b8-44df-bd7e-aea1271f9ace", "name": "0f43caab-2a22-4b0f-8055-033e5a86d4da_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2795803428770153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1698974287191981, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f9eb67dd-74bc-4c46-831e-e02d1fb1d898", "name": "88e50214-eb50-4621-b000-3d73ab001257", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eabfde0e-54b8-44df-bd7e-aea1271f9ace"}}}]}, {"uuid": "dea108c1-e877-4a90-8f38-feaf33fb1e3b", "name": "load_p1rlv15618_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "200aa7d8-0a43-4086-b0e7-f63cae75671d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f9eb67dd-74bc-4c46-831e-e02d1fb1d898"}}}}, {"uuid": "72e1553d-91d7-47c0-a4eb-4e5b1bb3bed1", "name": "80570795-9843-475c-9431-752d767622cc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2795803428770153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1698974287191981, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9519faae-cb8f-4544-8ea7-cb5f9a681c54", "name": "d14c1fab-bf8a-42c8-8b83-33d7dd168bf8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72e1553d-91d7-47c0-a4eb-4e5b1bb3bed1"}}}]}, {"uuid": "9e1f6c2e-94d7-4757-b33b-82228d4eabd2", "name": "load_p1rlv15618_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "200aa7d8-0a43-4086-b0e7-f63cae75671d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9519faae-cb8f-4544-8ea7-cb5f9a681c54"}}}}, {"uuid": "b092f45d-9015-4c29-a4a7-b76faa9b58f0", "name": "9c39cbd7-0fe5-4467-a773-210bfae39bd0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8454259827639654, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5306926284494342, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "065a8765-34d9-4f06-9611-d4f0c1216795", "name": "a23ad787-c2d5-496e-925e-33372bfc20a6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b092f45d-9015-4c29-a4a7-b76faa9b58f0"}}}]}, {"uuid": "f762ccda-562f-486a-9c52-40097d41b4da", "name": "load_p1rlv15619_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905a4857-5d3d-4e51-9ab0-70d634170f92"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "065a8765-34d9-4f06-9611-d4f0c1216795"}}}}, {"uuid": "e4498d19-aa92-4345-a2ac-ff62048aeb4c", "name": "fbbad8a2-7d6a-4e4d-b380-17af10ae674a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8454259827639654, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5306926284494342, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d223123b-5936-4b5f-8033-2e9c6b2c90fb", "name": "3dc826b0-e993-46b2-acdb-f78e8576f816", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e4498d19-aa92-4345-a2ac-ff62048aeb4c"}}}]}, {"uuid": "d30393bc-6418-416e-83ac-29f25e4da89f", "name": "load_p1rlv15619_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905a4857-5d3d-4e51-9ab0-70d634170f92"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d223123b-5936-4b5f-8033-2e9c6b2c90fb"}}}}, {"uuid": "3ea87847-071d-451f-bd19-6d82c1ce111f", "name": "aa9ec67c-7807-4a16-acdf-62bc65f7fa19_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5924067901709626, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.46681640832512994, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "08427ead-ad00-4a10-a10d-e7d4da17a254", "name": "a2e361e0-b106-43a0-906c-35a429e96aea", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3ea87847-071d-451f-bd19-6d82c1ce111f"}}}]}, {"uuid": "1904ede3-a1c8-4565-adc7-d679845b0c95", "name": "load_p1rlv15623_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13f790a1-18c0-498f-8525-fbaf0350947b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "08427ead-ad00-4a10-a10d-e7d4da17a254"}}}}, {"uuid": "4f3fa56d-4b8b-47bc-8a88-d4518112bfbb", "name": "49271121-f195-4dc2-9617-3e41417e9f63_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5924067901709626, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.46681640832512994, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ddfbadbd-d94a-463c-b3fa-a1586a9f8ff3", "name": "e9f05cd5-7af3-4225-81e8-0d9267e8fa64", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4f3fa56d-4b8b-47bc-8a88-d4518112bfbb"}}}]}, {"uuid": "95a7b4d1-8c53-42fd-8fe4-74537a2ee45a", "name": "load_p1rlv15623_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13f790a1-18c0-498f-8525-fbaf0350947b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ddfbadbd-d94a-463c-b3fa-a1586a9f8ff3"}}}}, {"uuid": "1d62a7aa-8b10-44bd-ace9-bf5f8061dd23", "name": "f3ee2678-10a3-407d-a28b-1259924b2b44_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6658189308849048, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3864031015392916, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ee3e309b-bd35-40cd-b2b0-6498a1ff6210", "name": "df422b58-6f34-4522-86e9-cd47c632de13", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1d62a7aa-8b10-44bd-ace9-bf5f8061dd23"}}}]}, {"uuid": "fa99cc7b-2e73-4524-b411-78eacbc75990", "name": "load_p1rlv15625_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb08eda2-b277-4bfd-9ea0-9c36765400bd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ee3e309b-bd35-40cd-b2b0-6498a1ff6210"}}}}, {"uuid": "2a5215a6-8da4-4afa-a0b7-3cef1822b4ef", "name": "8877d052-007c-40eb-a879-4f58aa9e7211_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6658189308849048, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3864031015392916, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b6bfe314-6117-4811-b014-92996f13c84f", "name": "6fa26fb9-a44a-4269-84ab-a6b6259ca31f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2a5215a6-8da4-4afa-a0b7-3cef1822b4ef"}}}]}, {"uuid": "87950dc1-c23f-454f-845e-94f5fbb13603", "name": "load_p1rlv15625_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb08eda2-b277-4bfd-9ea0-9c36765400bd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b6bfe314-6117-4811-b014-92996f13c84f"}}}}, {"uuid": "be3ca802-c7d2-47de-972d-322cd93807e5", "name": "a17e6c75-25ef-446e-861a-3263eef75cc6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3315344999322854, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13574204648198762, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "93b4ac9f-fd66-4459-b9b2-a60a7625fdd6", "name": "1b46f718-4f26-4402-a080-7744de60b05b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "be3ca802-c7d2-47de-972d-322cd93807e5"}}}]}, {"uuid": "ad0a8ed6-24d4-4e8f-ac53-88c9b689021e", "name": "load_p1rlv15632_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ccbef4c-6bf7-4892-a3b9-b51aca495137"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "93b4ac9f-fd66-4459-b9b2-a60a7625fdd6"}}}}, {"uuid": "c810fca3-d772-4a8f-9082-c6e72ac4e6db", "name": "6d0f8720-ca97-4483-85b1-fcfbc3d9a247_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3315344999322854, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13574204648198762, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eb7dc31a-acec-41e8-9d07-1c90bf9490b1", "name": "d7af0015-c346-4b4e-a53e-6fa094559f64", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c810fca3-d772-4a8f-9082-c6e72ac4e6db"}}}]}, {"uuid": "b326beb8-6531-4490-84c5-a9014d18cd2f", "name": "load_p1rlv15632_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ccbef4c-6bf7-4892-a3b9-b51aca495137"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eb7dc31a-acec-41e8-9d07-1c90bf9490b1"}}}}, {"uuid": "9e89186f-82c8-41ae-9f16-c28e00c70659", "name": "d62a87d2-b3fd-4ff1-a057-d63355bf6822_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4063851199490187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16385595528128288, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bbc4101b-7e69-4f71-ae4f-53856d686d1e", "name": "2c8f31ec-0268-4a3f-801f-a40f82c15c62", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9e89186f-82c8-41ae-9f16-c28e00c70659"}}}]}, {"uuid": "375a5e05-3568-4779-b978-37d6522d61fb", "name": "load_p1rlv15633_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce7b60c8-43ee-441d-9f18-5b2722dcc0a7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bbc4101b-7e69-4f71-ae4f-53856d686d1e"}}}}, {"uuid": "9f5b58b3-7848-4775-845e-a70f87019061", "name": "35b90394-c4d5-42e8-b3ed-6a734fc56860_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4063851199490187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16385595528128288, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f85b18e2-a935-4f00-bcc3-eb8850675b5f", "name": "d22eb452-a604-4f20-9803-82933df8d181", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9f5b58b3-7848-4775-845e-a70f87019061"}}}]}, {"uuid": "fd01f3fc-80cc-451d-ba6b-6cdba33c7311", "name": "load_p1rlv15633_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce7b60c8-43ee-441d-9f18-5b2722dcc0a7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f85b18e2-a935-4f00-bcc3-eb8850675b5f"}}}}, {"uuid": "2300e2b1-e466-437d-af39-12dc106ea0f1", "name": "7083a3fa-3140-4ecb-8a87-8c51ca8cac19_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.416529851525178, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1922168413006689, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7b14e0f6-ca0f-4794-8615-bd6fd05cc72d", "name": "ec7fc012-219d-49fd-a2f2-21417ffd3ed0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2300e2b1-e466-437d-af39-12dc106ea0f1"}}}]}, {"uuid": "cc963929-deac-4c2d-93ca-eec6f3895b48", "name": "load_p1rlv15640_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83c2de51-1b04-483c-8ce7-14b9e5e027b9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7b14e0f6-ca0f-4794-8615-bd6fd05cc72d"}}}}, {"uuid": "c18fc0b9-d5ea-4253-b272-6a950aa0a4a2", "name": "20882bd3-8746-4413-a346-e24319680df6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.416529851525178, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1922168413006689, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "73414de7-7f37-44cd-a4ca-74716bb26fa2", "name": "106eb0d3-138e-4640-8725-abd2ec7b195f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c18fc0b9-d5ea-4253-b272-6a950aa0a4a2"}}}]}, {"uuid": "8de61cc1-a633-4ef4-ad8d-12c1c479f199", "name": "load_p1rlv15640_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83c2de51-1b04-483c-8ce7-14b9e5e027b9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "73414de7-7f37-44cd-a4ca-74716bb26fa2"}}}}, {"uuid": "27831177-8035-4f9b-b8ff-9d9ea31439af", "name": "69f11f40-bb60-4012-8526-4aad1d2aa1ab_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7538406343539102, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42176934505781605, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4e2d6287-dbf6-47f8-b6f0-bf31d11f7660", "name": "9556de5c-ea12-4b65-ba76-b3e4676b8b38", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "27831177-8035-4f9b-b8ff-9d9ea31439af"}}}]}, {"uuid": "0b6ca4e4-706a-4f46-abf0-c6bc68a0ddac", "name": "load_p1rlv15641_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4363602a-eb9c-41b8-8130-7bb839f4eb5a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4e2d6287-dbf6-47f8-b6f0-bf31d11f7660"}}}}, {"uuid": "873fe6a2-2e17-4658-b8f6-1a976d9d758f", "name": "8823a533-2fa9-4c9d-b797-0df5529291c2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7538406343539102, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42176934505781605, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "de902fe0-2d32-42b3-a757-0dba337785ad", "name": "89d360e4-e1c1-43c5-bad9-2f3f7ea7c261", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "873fe6a2-2e17-4658-b8f6-1a976d9d758f"}}}]}, {"uuid": "434acaad-5c0d-49d4-a568-2850f9fd6300", "name": "load_p1rlv15641_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4363602a-eb9c-41b8-8130-7bb839f4eb5a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "de902fe0-2d32-42b3-a757-0dba337785ad"}}}}, {"uuid": "b5d548f7-c235-4f56-a5e8-73b437dfec64", "name": "2dcf3af2-8b6d-4f62-ace6-d8e121983252_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.735884899619907, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7862059386133167, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ea218f6e-dfd3-438b-adcf-852aa343204b", "name": "28b3c749-4582-4f26-9e07-d9887cd70465", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5d548f7-c235-4f56-a5e8-73b437dfec64"}}}]}, {"uuid": "31e35185-7faa-4548-a082-94b778d715eb", "name": "load_p1rlv16450_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5f1e7aa-d93a-4164-8bc0-f920259304a8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ea218f6e-dfd3-438b-adcf-852aa343204b"}}}}, {"uuid": "92762c3b-686c-4ce0-9e31-45def15ff6d2", "name": "82753a5d-5757-46fd-b47b-63058b1199e2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.735884899619907, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7862059386133167, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5a3f23f0-a34b-4071-93c5-5d8151415cd1", "name": "8e27ec17-be51-429a-8af7-638943f57ef9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "92762c3b-686c-4ce0-9e31-45def15ff6d2"}}}]}, {"uuid": "6dd3a333-b113-4ad1-9cfc-2ee8193aa02c", "name": "load_p1rlv16450_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5f1e7aa-d93a-4164-8bc0-f920259304a8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5a3f23f0-a34b-4071-93c5-5d8151415cd1"}}}}, {"uuid": "d18f355d-432d-4a81-9f79-60ce72b17264", "name": "cb98fa40-de8c-4a97-bb6c-3b878a09ab9c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5229589832640044, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3359880712066463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7ce996db-a06e-43c8-b644-32f3f75d9413", "name": "8e4e1985-8cc9-45fc-8143-fc433d8de810", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d18f355d-432d-4a81-9f79-60ce72b17264"}}}]}, {"uuid": "9fb0240a-337c-448b-9787-66aea3750bf3", "name": "load_p1rlv16463_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9c505d7-3fb9-4eb5-89c6-c9c8da32fd05"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7ce996db-a06e-43c8-b644-32f3f75d9413"}}}}, {"uuid": "3e585105-6eb1-4266-852c-d96bef3e20ae", "name": "9ac799f5-91b0-4380-a5f3-e07f877df701_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5229589832640044, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3359880712066463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8c691fc0-826c-469b-8458-924b9d4bb2a5", "name": "8bbcadb3-5213-4a50-8ee5-177fdb53534a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3e585105-6eb1-4266-852c-d96bef3e20ae"}}}]}, {"uuid": "22237d0f-60d8-42bf-a53a-99468f18ea7d", "name": "load_p1rlv16463_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9c505d7-3fb9-4eb5-89c6-c9c8da32fd05"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8c691fc0-826c-469b-8458-924b9d4bb2a5"}}}}, {"uuid": "72f9e304-6f77-4048-b244-b47d987386d5", "name": "4354d6de-b840-4a59-921c-48546a5918ba_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.868352089343376, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.8531787232937273, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "93240c18-7579-465b-b310-1d14ad8e8dd2", "name": "1b380adb-20db-4447-a4b5-36eb7224e1cd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72f9e304-6f77-4048-b244-b47d987386d5"}}}]}, {"uuid": "abdb5a0e-b49e-4045-8a50-c71f708e8057", "name": "load_p1rlv16475_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d400b1b2-8404-4b80-b110-6f96e000314f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "93240c18-7579-465b-b310-1d14ad8e8dd2"}}}}, {"uuid": "888d1efa-55da-4fa0-8fdb-34cd43bddd9c", "name": "a7c7a516-35b1-4b3f-879d-b052684964fa_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.868352089343376, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.8531787232937273, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "de871ffd-f009-4ca8-a997-be1e4f88ae66", "name": "28e02cf2-5047-48fa-b542-ae2aa753401c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "888d1efa-55da-4fa0-8fdb-34cd43bddd9c"}}}]}, {"uuid": "7022f268-f6f5-4642-84f1-7377872a39a4", "name": "load_p1rlv16475_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d400b1b2-8404-4b80-b110-6f96e000314f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "de871ffd-f009-4ca8-a997-be1e4f88ae66"}}}}, {"uuid": "e54ec48a-9076-420f-9ddf-0ab004897c81", "name": "ad316ba8-bdcf-4aee-9cab-506969847b73_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8816313976351899, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.38647586315113985, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b570d166-7b24-49d5-88c7-3c2de440b7aa", "name": "46e26fb5-cd03-4009-bee3-b4653939f1ce", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e54ec48a-9076-420f-9ddf-0ab004897c81"}}}]}, {"uuid": "8dc71af4-8b75-4782-aebf-fbdb147c277f", "name": "load_p1rlv16483_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa6db7ee-126d-4aa9-9733-35ff1c1d5992"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b570d166-7b24-49d5-88c7-3c2de440b7aa"}}}}, {"uuid": "7c2bbc90-c373-4787-802b-91686bbd16d5", "name": "090e10fe-03aa-46ba-94f3-4af619297bc0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8816313976351899, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.38647586315113985, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "74fecb5e-7b8c-4aad-8bf6-f551ad043802", "name": "e5f549bd-698c-4aeb-a297-e7da4d5ac566", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7c2bbc90-c373-4787-802b-91686bbd16d5"}}}]}, {"uuid": "4efd8407-afeb-45a9-a658-989c9fd49d4c", "name": "load_p1rlv16483_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa6db7ee-126d-4aa9-9733-35ff1c1d5992"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "74fecb5e-7b8c-4aad-8bf6-f551ad043802"}}}}, {"uuid": "6a389484-bc0c-4d4a-9d31-54a1bac5a030", "name": "517e95b3-d4e7-426f-a862-33d7532e6650_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8285317723273034, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9836303634928509, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50c5124f-e767-48e1-8fa3-c1f23dc1d946", "name": "a0ff77a5-a9f2-47c3-a9f0-0e6549119ed2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6a389484-bc0c-4d4a-9d31-54a1bac5a030"}}}]}, {"uuid": "f0aac045-0e01-4455-a8d7-50f8a24b39c3", "name": "load_p1rlv16507_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27afe70a-9123-4b0c-9f50-b5355aafcf7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50c5124f-e767-48e1-8fa3-c1f23dc1d946"}}}}, {"uuid": "c1f72a93-2c6d-40f0-9e88-066edd0bc299", "name": "2473520e-3c51-4226-8681-2bf2d8f864ed_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8285317723273034, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9836303634928509, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "46e400db-45a5-4016-81f6-e5e8c50fe0cf", "name": "ae99d7bd-fb17-4727-8fa6-b70d61ae23d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c1f72a93-2c6d-40f0-9e88-066edd0bc299"}}}]}, {"uuid": "f9802863-0ac4-4648-9bc4-1868376b0046", "name": "load_p1rlv16507_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27afe70a-9123-4b0c-9f50-b5355aafcf7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "46e400db-45a5-4016-81f6-e5e8c50fe0cf"}}}}, {"uuid": "f3ad0ef9-ac5b-424c-8d55-c35e3ec43d71", "name": "5d16bf4b-825c-48d8-a9f2-9591f938775a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6976007564693765, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0012223642000246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ffe7b4e6-144c-462e-b003-deb4036a99ea", "name": "3d434c4a-07a6-4e66-ac93-41189685d682", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f3ad0ef9-ac5b-424c-8d55-c35e3ec43d71"}}}]}, {"uuid": "fd615f28-bdaf-4b10-9f8b-29ce22898ce0", "name": "load_p1rlv16530_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0333a34b-4027-4d9a-9d4a-f867c8a317bc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ffe7b4e6-144c-462e-b003-deb4036a99ea"}}}}, {"uuid": "00566696-d4c5-4a31-a3ea-5c779c66ed5f", "name": "a348b52e-9808-4ede-8bdb-17768e1e41f4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6976007564693765, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0012223642000246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c715d386-cc2d-42e8-89f5-4da411227d56", "name": "e6ec601a-04c7-431c-883b-c60ba0d73b21", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "00566696-d4c5-4a31-a3ea-5c779c66ed5f"}}}]}, {"uuid": "5b4755a8-7f30-4e67-99cc-615124fa8969", "name": "load_p1rlv16530_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0333a34b-4027-4d9a-9d4a-f867c8a317bc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c715d386-cc2d-42e8-89f5-4da411227d56"}}}}, {"uuid": "7c3feb6e-7699-4b8b-bf81-a1303d4ac613", "name": "b00d351f-caff-4efb-8285-802db0138ef5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4622944887503224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10483650830237357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4aae7ad0-4668-4e2e-b349-05395e064136", "name": "c6792b81-42b7-4e82-b405-1329e781b3c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7c3feb6e-7699-4b8b-bf81-a1303d4ac613"}}}]}, {"uuid": "a6fd724d-b412-4387-baec-28ba0a8ae5c1", "name": "load_p1rlv16541_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f7be042-6681-4694-872d-a1cb701016c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4aae7ad0-4668-4e2e-b349-05395e064136"}}}}, {"uuid": "d789f394-4e99-4645-94a6-dd32d419c082", "name": "b66e098d-d15f-4275-b427-18e96faa709b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4622944887503224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10483650830237357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6377f5e3-4e07-4044-bdd0-6e24cf13cf0b", "name": "1276e012-d2e9-4117-a1a2-3d977832a75a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d789f394-4e99-4645-94a6-dd32d419c082"}}}]}, {"uuid": "87a3f4ec-41e0-4b20-ab89-7fb590e660c7", "name": "load_p1rlv16541_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f7be042-6681-4694-872d-a1cb701016c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6377f5e3-4e07-4044-bdd0-6e24cf13cf0b"}}}}, {"uuid": "6c69e703-71cd-486d-ad05-17837f07fddc", "name": "2ced9ebc-d211-443f-9e72-af7d95d3849a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.962510599658346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.39927803268124257, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3e01c7b8-27b5-4ec3-8f06-3389efbecb65", "name": "9af5c881-7e46-4b5e-a998-959c23794c2e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c69e703-71cd-486d-ad05-17837f07fddc"}}}]}, {"uuid": "94d30e7c-66e1-41e1-9fd0-101444495776", "name": "load_p1rlv16573_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90d9dbe9-f9c9-4a4e-8ada-cb459778687b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3e01c7b8-27b5-4ec3-8f06-3389efbecb65"}}}}, {"uuid": "676745fc-79d7-458c-9e05-6e092caa2b3f", "name": "1a1a8e15-1ec4-4929-97f2-cc5316e1bc83_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.962510599658346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.39927803268124257, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0e2c3022-4cb6-446b-ae2c-3428b4af05af", "name": "336a777f-09ce-4bf3-b11a-3cbe06f7619d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "676745fc-79d7-458c-9e05-6e092caa2b3f"}}}]}, {"uuid": "1b19dde5-8cdf-4897-a926-2c48ebc763a9", "name": "load_p1rlv16573_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90d9dbe9-f9c9-4a4e-8ada-cb459778687b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0e2c3022-4cb6-446b-ae2c-3428b4af05af"}}}}, {"uuid": "17418aba-721c-4315-94ab-f8def94d1c19", "name": "fce4c617-6785-4a22-b6a1-ff8dec801232_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6976007564693765, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0012223642000246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ddd490af-260d-46e4-8ca9-b21cc6bc2d46", "name": "f35dc42e-9781-4443-84df-4a624454cc9f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "17418aba-721c-4315-94ab-f8def94d1c19"}}}]}, {"uuid": "397456e3-3cb5-470b-be37-3e79d3c899ed", "name": "load_p1rlv16584_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "344c6b21-94c9-4912-a19e-69fbae5eed27"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ddd490af-260d-46e4-8ca9-b21cc6bc2d46"}}}}, {"uuid": "f6211fd3-d0ef-414f-8de3-78c78457a87b", "name": "6aa9bc57-2165-459d-b3a6-36c43fcac88b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6976007564693765, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0012223642000246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2a865d4a-7f45-47ee-92b3-1f9e5a08b46e", "name": "81959ead-a5ed-4ab3-b74d-0ab0b5855cbe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f6211fd3-d0ef-414f-8de3-78c78457a87b"}}}]}, {"uuid": "b535f7e2-9aa2-4481-8507-d774c5c8dd99", "name": "load_p1rlv16584_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "344c6b21-94c9-4912-a19e-69fbae5eed27"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2a865d4a-7f45-47ee-92b3-1f9e5a08b46e"}}}}, {"uuid": "7648cf74-49da-4631-b023-8a26cdff5a97", "name": "db32424a-4750-4cf6-8cb1-bca90476f529_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4820522770729507, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1125677048872814, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "80554816-b458-45b0-8147-a0037851a770", "name": "7166e439-29ab-4ca8-97ad-b062ea3cdbf4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7648cf74-49da-4631-b023-8a26cdff5a97"}}}]}, {"uuid": "4e358a7e-2f97-47f3-b250-04a30db6372c", "name": "load_p1rlv16604_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f9ecb3f-8b64-4598-a9d1-d794c6800d33"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "80554816-b458-45b0-8147-a0037851a770"}}}}, {"uuid": "d64daa14-f7d7-453a-b0a2-b461372c8200", "name": "8a74909b-00b5-4d43-a62c-e396702c1c31_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4820522770729507, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1125677048872814, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "888cb114-7f8f-4d27-b18c-9a8bdf45a92e", "name": "2ac3ef4a-cebc-4d3c-a28c-3690ee0ba266", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d64daa14-f7d7-453a-b0a2-b461372c8200"}}}]}, {"uuid": "e0a235d2-9c25-45cd-a2c3-f08de8da1c81", "name": "load_p1rlv16604_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f9ecb3f-8b64-4598-a9d1-d794c6800d33"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "888cb114-7f8f-4d27-b18c-9a8bdf45a92e"}}}}, {"uuid": "6b32ecbb-ef6d-492e-8dcb-52e75307d744", "name": "ad0f3347-eb7f-4599-800f-4b0b8801488a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8791002615066037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24190904367644575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "050f8a43-86e9-440e-9013-a602a5347d35", "name": "a22947a6-bcbc-4935-aba8-86f0843db3d7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6b32ecbb-ef6d-492e-8dcb-52e75307d744"}}}]}, {"uuid": "c35648e4-98a8-4b53-93f4-c9832c9a4772", "name": "load_p1rlv17239_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba567aae-a893-41d3-8fd1-8357d3cab35d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "050f8a43-86e9-440e-9013-a602a5347d35"}}}}, {"uuid": "145622c3-10b0-43f9-b6eb-5fba18da4dc7", "name": "cbe728db-d030-4a08-a9ae-2f266c38827d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8791002615066037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24190904367644575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2d231892-6703-4130-9edf-3084ca95ef2d", "name": "4ea83401-f40a-499f-bbf0-b3f2158897dc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "145622c3-10b0-43f9-b6eb-5fba18da4dc7"}}}]}, {"uuid": "fa50fe3e-5e73-434b-8f50-8a2a6a1d4b63", "name": "load_p1rlv17239_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba567aae-a893-41d3-8fd1-8357d3cab35d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2d231892-6703-4130-9edf-3084ca95ef2d"}}}}, {"uuid": "fcd97511-4190-4064-a54f-9874215e5e8f", "name": "59d5dc07-dbbc-48cc-bfdc-ea9b13fbbd10_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.664483224984605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9538644530515166, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e271eab7-9cd8-42f1-b8c0-0c11acf307d8", "name": "52fd7431-2ac2-402d-ac11-d8f5d4afe61b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fcd97511-4190-4064-a54f-9874215e5e8f"}}}]}, {"uuid": "d2090903-e858-43d0-bed5-eacf872228dd", "name": "load_p1rlv17246_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acfdbe95-2d82-463a-9d1f-6fd2688adf16"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e271eab7-9cd8-42f1-b8c0-0c11acf307d8"}}}}, {"uuid": "1e737e3c-83b0-4326-bf8f-b6acae50638d", "name": "9ee4961e-7303-4ff5-834c-32b092f8dde4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.664483224984605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9538644530515166, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d2309fed-4bd6-4ec1-a07c-9776f9d23797", "name": "d8a40c85-27ed-4609-81cb-53106e525a8b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1e737e3c-83b0-4326-bf8f-b6acae50638d"}}}]}, {"uuid": "6deb03f4-71f9-4740-b29a-428e44a88afa", "name": "load_p1rlv17246_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acfdbe95-2d82-463a-9d1f-6fd2688adf16"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d2309fed-4bd6-4ec1-a07c-9776f9d23797"}}}}, {"uuid": "5b8bf031-4224-4dba-9afb-32fd4c970315", "name": "131b04d8-6670-4981-b729-cd45182c9312_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7073298240395912, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.27247283022117846, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ecdec3fa-0fe5-4adc-94e0-b2686c04e60d", "name": "2f40d2d5-37f0-45ff-bdf2-74489ec2cbf1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b8bf031-4224-4dba-9afb-32fd4c970315"}}}]}, {"uuid": "2a0175b3-9542-4c41-845a-5ef0855a6df3", "name": "load_p1rlv17280_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac80cbea-e10a-491a-ba36-06e9fcf74217"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ecdec3fa-0fe5-4adc-94e0-b2686c04e60d"}}}}, {"uuid": "d9fa4f4e-b7d1-4935-8353-239744c09582", "name": "88ca2756-2a7b-46ec-a7bb-074c65e03a8f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7073298240395912, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.27247283022117846, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9a872ec0-9bac-4b01-9536-7be722032b24", "name": "ad7fd0b0-d4bf-4805-9b76-018d3d997a28", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d9fa4f4e-b7d1-4935-8353-239744c09582"}}}]}, {"uuid": "711295f8-9158-44a8-8b6f-5f1498447996", "name": "load_p1rlv17280_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac80cbea-e10a-491a-ba36-06e9fcf74217"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9a872ec0-9bac-4b01-9536-7be722032b24"}}}}, {"uuid": "67a9a2c0-4038-4037-a2e9-7ff562687f15", "name": "23c1537f-8d8f-42ec-8c6b-6d3010087c0a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7675749799903273, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6204429178040327, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f8fc3ba-b7a7-436a-8419-5672be6c1c6a", "name": "a2d63641-53a1-4222-9271-95b4e71989a1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "67a9a2c0-4038-4037-a2e9-7ff562687f15"}}}]}, {"uuid": "b0ea80f7-43ec-44ce-afb5-79f392497f53", "name": "load_p1rlv17291_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04388b89-16fc-40b3-a060-5bc52032874e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f8fc3ba-b7a7-436a-8419-5672be6c1c6a"}}}}, {"uuid": "6676d674-277d-4c80-8d60-99a5c2e5f3c4", "name": "e6c387a3-ca6b-4306-accd-7e17124f02ae_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7675749799903273, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6204429178040327, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "292dc273-0cd2-4e35-aa1c-0c07bfb32add", "name": "0fd2deb4-9d5f-4a37-8208-13600ea0174d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6676d674-277d-4c80-8d60-99a5c2e5f3c4"}}}]}, {"uuid": "8b720fc4-a00e-41f8-9c68-51dc8f90af7f", "name": "load_p1rlv17291_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04388b89-16fc-40b3-a060-5bc52032874e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "292dc273-0cd2-4e35-aa1c-0c07bfb32add"}}}}, {"uuid": "10e86e9d-ca57-4db7-90d5-16cae37b75ba", "name": "80cbee2f-3ab1-4e74-937c-8f4e543a84e4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8744605841296944, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5892496700768608, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "256c9e8a-d0d8-4d4f-b53b-36e6005cab1b", "name": "30d361c3-0aab-4780-8248-faffdfce3d12", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "10e86e9d-ca57-4db7-90d5-16cae37b75ba"}}}]}, {"uuid": "ddea90dc-2e99-4402-91a1-84c31229f44e", "name": "load_p1rlv17303_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04eb7e32-e372-4cb0-94a7-ee418f400bda"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "256c9e8a-d0d8-4d4f-b53b-36e6005cab1b"}}}}, {"uuid": "2069dad0-4b69-4bcb-8fbf-3000584dfdbc", "name": "252eef92-b83b-4753-a651-aa2df01fb01c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8744605841296944, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5892496700768608, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4205920b-6ffd-4d2e-9965-9c548b00f7ca", "name": "29b34c55-66ec-4ca0-8156-33a3be3c9160", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2069dad0-4b69-4bcb-8fbf-3000584dfdbc"}}}]}, {"uuid": "5a0db9b8-a303-4e8f-8ce6-48034af5b2ce", "name": "load_p1rlv17303_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04eb7e32-e372-4cb0-94a7-ee418f400bda"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4205920b-6ffd-4d2e-9965-9c548b00f7ca"}}}}, {"uuid": "39fd1708-e184-4b5d-9036-627aa4903a72", "name": "f2a8f814-c6b3-47c8-b5d0-91d7bc1c9606_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.446531565278448, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9314679219387375, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2166fe2c-b301-44e5-a91b-374f6818f1b4", "name": "74c3edab-08c0-42f4-9445-44987245fb8f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "39fd1708-e184-4b5d-9036-627aa4903a72"}}}]}, {"uuid": "116e8dc6-181a-4c69-85f1-d6db4517f88d", "name": "load_p1rlv17311_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84ebd9bb-dc50-483d-a3c6-044682d4020c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2166fe2c-b301-44e5-a91b-374f6818f1b4"}}}}, {"uuid": "d45d4101-f6dd-4c03-8d23-4e324061add4", "name": "f28f4b69-0589-4998-834b-45744772adcb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.446531565278448, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9314679219387375, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a4efd325-ab67-4330-8d7d-a62e6aec7d3e", "name": "183af1aa-33b5-47d7-895a-7bab90843791", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d45d4101-f6dd-4c03-8d23-4e324061add4"}}}]}, {"uuid": "b50f50bb-1c6e-428f-87db-f970d8bd0257", "name": "load_p1rlv17311_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84ebd9bb-dc50-483d-a3c6-044682d4020c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a4efd325-ab67-4330-8d7d-a62e6aec7d3e"}}}}, {"uuid": "3b56692e-8300-4a54-b121-6b2f3e460062", "name": "6110bf2f-bfca-4a3b-9a92-e766fd8b17b9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.1528026683641635, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1483162213006746, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "025f9caf-f565-4cfd-afee-aee4bbdd1814", "name": "ed801105-f860-41fb-b2cb-97abb0aba42d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3b56692e-8300-4a54-b121-6b2f3e460062"}}}]}, {"uuid": "dc660c7e-6795-4d0c-b2d2-a293b5ad6c20", "name": "load_p1rlv17345_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ead5953-70f2-4db2-ba4d-d203c91d85c1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "025f9caf-f565-4cfd-afee-aee4bbdd1814"}}}}, {"uuid": "e3547a41-5cc3-4d5a-b8c1-443e4d8458eb", "name": "2c56459d-f1c9-4ea4-a11a-6145c16e5d9c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.1528026683641635, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1483162213006746, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "66a2f399-d485-4762-85b5-8a8609023535", "name": "396cda2b-d69c-48ed-a339-5569d54a14c4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e3547a41-5cc3-4d5a-b8c1-443e4d8458eb"}}}]}, {"uuid": "c7c05374-7e21-4d77-91d3-ef29d9ff446d", "name": "load_p1rlv17345_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ead5953-70f2-4db2-ba4d-d203c91d85c1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "66a2f399-d485-4762-85b5-8a8609023535"}}}}, {"uuid": "54c6339c-d9dd-4aee-9394-c9e0b47a0ad4", "name": "2142fbb6-48f3-4fa5-96e6-6078c0281251_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5261964028176471, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5335215898246958, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "38a6dfe5-5a67-41af-8cdb-f85c2ed8074f", "name": "3abae5ba-902f-489b-ac67-d322cfc39009", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "54c6339c-d9dd-4aee-9394-c9e0b47a0ad4"}}}]}, {"uuid": "ef1c7d14-31c7-428c-9e7f-77573cc919e4", "name": "load_p1rlv17347_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d98640c6-d8aa-44e4-9ecf-5998152d3f7d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "38a6dfe5-5a67-41af-8cdb-f85c2ed8074f"}}}}, {"uuid": "d8bdd3b2-05e8-4baa-989c-71c97851d72a", "name": "478c6353-119e-4c78-99f0-8843ffd338db_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5261964028176471, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5335215898246958, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "383e8d73-e53c-4d55-8738-c313c36771e2", "name": "17dae6e6-7c19-4bae-b2cf-b0cc703ca8d4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d8bdd3b2-05e8-4baa-989c-71c97851d72a"}}}]}, {"uuid": "e63b5a6b-93d0-430a-8209-4d24137aebea", "name": "load_p1rlv17347_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d98640c6-d8aa-44e4-9ecf-5998152d3f7d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "383e8d73-e53c-4d55-8738-c313c36771e2"}}}}, {"uuid": "ae5cf2b9-af7a-496d-94ee-9bf57047dee6", "name": "e5e8940f-84fa-4ec3-8975-714342c23e01_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1461342593009323, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5165512162199262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6fab1a1c-4a75-4dd4-930a-b92164297677", "name": "a37d4c59-cf96-4e28-b72c-4b0f54142d95", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ae5cf2b9-af7a-496d-94ee-9bf57047dee6"}}}]}, {"uuid": "0db124db-f2cf-452e-af15-005da2d72994", "name": "load_p1rlv17351_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2695decb-d268-46b2-8604-9c33dc90518b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6fab1a1c-4a75-4dd4-930a-b92164297677"}}}}, {"uuid": "72d51562-9cfa-4874-ab5b-1a14664df786", "name": "4c5373c5-b67d-4963-ad2a-c14c49a86058_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1461342593009323, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5165512162199262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "864ed71a-eb04-45e5-b8fa-07574a13b6e3", "name": "73a98dfa-1d29-4054-a6e4-d627fa9e4407", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72d51562-9cfa-4874-ab5b-1a14664df786"}}}]}, {"uuid": "2cb117f5-e198-4644-b51e-fea0f165b412", "name": "load_p1rlv17351_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2695decb-d268-46b2-8604-9c33dc90518b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "864ed71a-eb04-45e5-b8fa-07574a13b6e3"}}}}, {"uuid": "a1508534-c554-4a7d-ac1d-5ad0675b7b51", "name": "3ca2e239-a8d3-48d2-8295-0bd4717ea50c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3232710990419903, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5137832846214487, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f36cea0-29e7-467b-8526-a245406e1116", "name": "7874fd6c-3bb4-4bc4-ba13-b84a17dc0816", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a1508534-c554-4a7d-ac1d-5ad0675b7b51"}}}]}, {"uuid": "8295aded-e172-4d6b-a633-3b9c8e2455d9", "name": "load_p1rlv17353_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f34e3e4e-bebd-4148-bcc7-cbfbecd73a2f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f36cea0-29e7-467b-8526-a245406e1116"}}}}, {"uuid": "c9828856-d2c7-48b9-8226-5488cececd61", "name": "24908e2e-d087-4018-b785-36f46ac813b3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3232710990419903, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5137832846214487, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0add286a-19e4-4b8d-9bda-00b9c2e5fcfa", "name": "a7a56e81-5fdc-4f18-baf3-05794ccd7f2e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9828856-d2c7-48b9-8226-5488cececd61"}}}]}, {"uuid": "2767aad3-6719-4959-afa3-9482f210f809", "name": "load_p1rlv17353_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f34e3e4e-bebd-4148-bcc7-cbfbecd73a2f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0add286a-19e4-4b8d-9bda-00b9c2e5fcfa"}}}}, {"uuid": "9bc673b5-7b9b-4aa3-ad4e-22d7ec4068b9", "name": "0f4380b6-64d1-427f-8eb3-dd485b015c70_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5604078463831266, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5882122505209306, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "56dc1c65-0c11-445a-a030-11c2775fcfe1", "name": "f4992301-55dc-469d-bbd6-a908b8faa4c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9bc673b5-7b9b-4aa3-ad4e-22d7ec4068b9"}}}]}, {"uuid": "9fe63a69-17bf-46d7-8bc0-704c3f433fae", "name": "load_p1rlv17357_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf6f74e5-7aa3-4333-bd37-3ce486d54a01"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "56dc1c65-0c11-445a-a030-11c2775fcfe1"}}}}, {"uuid": "8d77143d-1380-4250-a50a-e2244879c93d", "name": "c833d713-1517-4209-bc87-50c6feb870d5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5604078463831266, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5882122505209306, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "60323c30-163d-4b00-8887-89f05a5c7679", "name": "ad5709c4-84f7-4133-b49e-13f5194ccf6e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8d77143d-1380-4250-a50a-e2244879c93d"}}}]}, {"uuid": "fa9b2054-5253-4415-8889-259ad0b84cb5", "name": "load_p1rlv17357_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf6f74e5-7aa3-4333-bd37-3ce486d54a01"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "60323c30-163d-4b00-8887-89f05a5c7679"}}}}, {"uuid": "0004e21c-fcf1-4336-8757-a830465658bd", "name": "7252e071-aae1-44aa-a36f-3458e438804d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.567401274738218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6497123013243786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b2137268-c524-4b5f-a351-ffca79fa6184", "name": "c96b7d7f-9fbb-4a4e-ac22-6c17f2a937e0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0004e21c-fcf1-4336-8757-a830465658bd"}}}]}, {"uuid": "5866fcc4-8763-4e06-8c22-e45bba83eeda", "name": "load_p1rlv17361_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c705333f-6f1a-4a76-a02e-eaa859e99b70"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b2137268-c524-4b5f-a351-ffca79fa6184"}}}}, {"uuid": "aa0b02dc-dd07-40da-953a-4563476e6b85", "name": "583fa5ad-46f4-4b34-a1fd-8b637038e0b6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.567401274738218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6497123013243786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3c48eb75-79db-455e-acea-d04d9228136e", "name": "40a2a226-9af9-465a-98a1-30ac408dc218", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aa0b02dc-dd07-40da-953a-4563476e6b85"}}}]}, {"uuid": "df57747a-1083-4403-b872-5fa1c16e3951", "name": "load_p1rlv17361_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c705333f-6f1a-4a76-a02e-eaa859e99b70"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3c48eb75-79db-455e-acea-d04d9228136e"}}}}, {"uuid": "21bb361e-140f-456c-867f-44050003f17a", "name": "a83313d8-cf7c-4295-8b8f-b5ccfde74f81_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.582045467287543, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.1165769169460202, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0344d223-50ec-43ff-9c12-5c3fae83d370", "name": "652b3ce1-f545-4216-a860-97b04ba23934", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "21bb361e-140f-456c-867f-44050003f17a"}}}]}, {"uuid": "9406461e-6e4c-4502-a0a6-9614beb56faf", "name": "load_p1rlv17378_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08709e25-b030-4801-ae00-c4879556d8b1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0344d223-50ec-43ff-9c12-5c3fae83d370"}}}}, {"uuid": "713e7ec4-ff6e-4d92-b490-46362a155cb1", "name": "1ac7f2e1-6b1d-4883-afdd-319145a5ce64_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.582045467287543, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.1165769169460202, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d0345c42-36a9-4e16-95a9-4918e096f297", "name": "37bd6084-79d6-414b-a304-86a2d943c6a4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "713e7ec4-ff6e-4d92-b490-46362a155cb1"}}}]}, {"uuid": "9e157d0c-0565-4de8-92f7-1bc70e4014bb", "name": "load_p1rlv17378_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08709e25-b030-4801-ae00-c4879556d8b1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d0345c42-36a9-4e16-95a9-4918e096f297"}}}}, {"uuid": "43bb55d1-718c-46de-8ca2-64642aa77b21", "name": "cb9facd3-eec8-422b-8dc2-06031991e10e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.833192950896713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0261472784856227, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e11461e0-e866-4176-85d0-d4ba5f5eaaf2", "name": "f44f14d3-16b1-42c3-9d87-a8f0f6e278f6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "43bb55d1-718c-46de-8ca2-64642aa77b21"}}}]}, {"uuid": "3c4a47db-8ffa-4ba2-852d-3df52e0e6aa6", "name": "load_p1rlv17383_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e1ad135-904d-47ed-ae74-32b38e1c2f88"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e11461e0-e866-4176-85d0-d4ba5f5eaaf2"}}}}, {"uuid": "6fe8413f-9acd-4df9-804d-3d71bd46fca3", "name": "b1eaef3e-9804-4d8a-a91a-acc53f697d5a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.833192950896713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0261472784856227, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6770a518-c900-41f2-a123-1488f7553cb8", "name": "259d81e9-8e67-4f7f-b719-ca0ba0de5c84", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6fe8413f-9acd-4df9-804d-3d71bd46fca3"}}}]}, {"uuid": "5212b428-d8b3-4f9a-a450-7f11c353f06e", "name": "load_p1rlv17383_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e1ad135-904d-47ed-ae74-32b38e1c2f88"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6770a518-c900-41f2-a123-1488f7553cb8"}}}}, {"uuid": "4ab1034a-22fe-4aaf-bf2b-3173f0915153", "name": "1e4d1724-790f-4aa3-a8d2-7ddcac6701a7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4147996191793286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7367936950300052, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "806d8710-c2d5-4753-b051-9ab47963f96f", "name": "7d275180-3049-4299-b88f-ef15fa8c8e3b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4ab1034a-22fe-4aaf-bf2b-3173f0915153"}}}]}, {"uuid": "356607c3-77d9-4189-9190-1ddafe1a961f", "name": "load_p1rlv17385_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e835b413-3307-49ef-ad69-cf18a5ae7cfb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "806d8710-c2d5-4753-b051-9ab47963f96f"}}}}, {"uuid": "838a242a-9611-443f-8c74-a88ff07a6caf", "name": "b2524670-8066-4464-960c-cb129261ded3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4147996191793286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7367936950300052, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4b5a2eae-e238-40d8-8baf-092e6388f195", "name": "dc596592-87c6-4f2e-aa82-a131c6439d44", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "838a242a-9611-443f-8c74-a88ff07a6caf"}}}]}, {"uuid": "4cc6a621-48bf-468c-8e56-766fac8208f2", "name": "load_p1rlv17385_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e835b413-3307-49ef-ad69-cf18a5ae7cfb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4b5a2eae-e238-40d8-8baf-092e6388f195"}}}}, {"uuid": "88b390e3-39d8-45bf-ae83-4d940000f48d", "name": "44b92c1f-cb76-49b0-900f-2ce73682d7aa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4341422169696036, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7357531788704136, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2965e5ae-a370-491d-bdb3-cc58fce2fb1b", "name": "c6281ae0-d87a-4b54-8fd1-9841a114e928", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "88b390e3-39d8-45bf-ae83-4d940000f48d"}}}]}, {"uuid": "697b77fe-e657-4fd7-b89b-d800d852f3a8", "name": "load_p1rlv17387_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "55382019-a1a5-40fd-b90a-072af40c2258"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2965e5ae-a370-491d-bdb3-cc58fce2fb1b"}}}}, {"uuid": "52de8749-2ec3-468f-a447-0c09d80b121f", "name": "b3e054d4-a5c9-4c00-bfb1-417a6151ff6c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4341422169696036, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7357531788704136, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "62c675f5-9c89-4388-b098-c8b697565974", "name": "ac2db679-d9a8-4f39-9764-967a6122356c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "52de8749-2ec3-468f-a447-0c09d80b121f"}}}]}, {"uuid": "4fa2fec5-5280-47dd-ace4-31d79610be5d", "name": "load_p1rlv17387_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "55382019-a1a5-40fd-b90a-072af40c2258"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "62c675f5-9c89-4388-b098-c8b697565974"}}}}, {"uuid": "0ca0f37c-a67b-40c0-945f-75485e693773", "name": "d89e5876-38f6-491b-ac24-1332746712e1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3557486353305213, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.524803205527562, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "229a6a7d-4723-41f9-b305-086b43fbf58e", "name": "b786ccbb-08f3-45f5-8f8d-e4fcf7fbd606", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0ca0f37c-a67b-40c0-945f-75485e693773"}}}]}, {"uuid": "f1f220d6-2c2d-4e91-bba9-6db42c260a03", "name": "load_p1rlv17391_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "169a22de-bb0a-4056-8910-151125c4ff9e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "229a6a7d-4723-41f9-b305-086b43fbf58e"}}}}, {"uuid": "3dbbb271-6748-435a-ac2a-880d5a37dc41", "name": "92c492ce-5b88-465c-8762-6a7de937bdd0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3557486353305213, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.524803205527562, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "187b5a26-62fe-4ec7-8514-c24ec27c8921", "name": "08f3dbc1-7f29-4b75-93f8-50b00087a8c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3dbbb271-6748-435a-ac2a-880d5a37dc41"}}}]}, {"uuid": "1002dba4-77bd-4cc9-b627-2a849d502d9b", "name": "load_p1rlv17391_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "169a22de-bb0a-4056-8910-151125c4ff9e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "187b5a26-62fe-4ec7-8514-c24ec27c8921"}}}}, {"uuid": "7b009349-73d7-4acb-9521-a26b06608d33", "name": "c837bdf3-fdf5-44f6-a1a8-7ee9ec55368f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.0707881481560175, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.1283140369898392, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "579385c8-f0f6-4477-b08a-a8ab9272c314", "name": "b6b4f40e-9c6f-4edf-a93e-c3923f293c9d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b009349-73d7-4acb-9521-a26b06608d33"}}}]}, {"uuid": "bb753700-3f23-44b4-b12e-611167da5587", "name": "load_p1rlv17394_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea560bcb-f930-4f42-ae45-3a60f36fdbb7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "579385c8-f0f6-4477-b08a-a8ab9272c314"}}}}, {"uuid": "3019877e-d0cb-43f8-8ab8-7519b5ad0168", "name": "82621ccf-7bba-48da-acb6-e4a98de4bbbf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.0707881481560175, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.1283140369898392, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ed8335fc-7c31-4da7-94a9-4666fecbf066", "name": "435980bf-ebd6-4c7b-9691-da263768536d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3019877e-d0cb-43f8-8ab8-7519b5ad0168"}}}]}, {"uuid": "ac8d96c4-d602-4fd1-9be2-5b10ed7c810c", "name": "load_p1rlv17394_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea560bcb-f930-4f42-ae45-3a60f36fdbb7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ed8335fc-7c31-4da7-94a9-4666fecbf066"}}}}, {"uuid": "5a5e5d7a-03e7-4a56-843e-84c1f6073e79", "name": "e496bdb3-1418-4e6b-a79b-952a4ec8d05a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.772705532239135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.33568286747913667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "70f7dfe6-a16a-426e-9286-34c5a396ced9", "name": "2979b272-bbde-4390-9125-d87da755935e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5a5e5d7a-03e7-4a56-843e-84c1f6073e79"}}}]}, {"uuid": "a69d0934-805d-44c8-8035-3bb4e1ad5e76", "name": "load_p1rlv17397_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d38cdffb-41be-48aa-8a03-c6525dd01037"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "70f7dfe6-a16a-426e-9286-34c5a396ced9"}}}}, {"uuid": "f35f7daf-422b-4ca4-af37-55eb6cef9b4c", "name": "8a1965b2-8b0c-4bc1-bc76-807ba9d11f4d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.772705532239135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.33568286747913667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dd91b777-3ae2-4333-923c-44c405bace58", "name": "0f76aa58-5610-4d56-bd20-56a677fd9318", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f35f7daf-422b-4ca4-af37-55eb6cef9b4c"}}}]}, {"uuid": "144ad946-e543-4e87-8c77-837a8d8da3b0", "name": "load_p1rlv17397_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d38cdffb-41be-48aa-8a03-c6525dd01037"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dd91b777-3ae2-4333-923c-44c405bace58"}}}}, {"uuid": "2407d8a8-67ea-4de5-9750-c11eb0683256", "name": "1db87372-bb6e-458b-a85f-4b38c1970474_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.072452566650022, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.19566580727582514, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e7c63da0-a165-46bd-aaf3-9d0575264d2f", "name": "0e15e527-5779-4f67-b1fe-61159d545837", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2407d8a8-67ea-4de5-9750-c11eb0683256"}}}]}, {"uuid": "3c899519-7224-4885-9d02-ee292723af0b", "name": "load_p1rlv17400_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63177299-2842-4e0d-bf17-7bd2b0afe9a2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e7c63da0-a165-46bd-aaf3-9d0575264d2f"}}}}, {"uuid": "3a3f2217-6cfb-4fad-89ac-4d06b8bc5bac", "name": "31309af2-1f78-4d21-9067-f5f127248951_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.072452566650022, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.19566580727582514, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d2669ad4-1f07-4b52-890e-83578641b89f", "name": "fb7a1148-b012-479a-adc2-a72ddc85c28e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3a3f2217-6cfb-4fad-89ac-4d06b8bc5bac"}}}]}, {"uuid": "7ef8ddb5-6d01-40c3-a749-97ba63adcdc0", "name": "load_p1rlv17400_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63177299-2842-4e0d-bf17-7bd2b0afe9a2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d2669ad4-1f07-4b52-890e-83578641b89f"}}}}, {"uuid": "5b874b04-da0b-4a51-bc6f-b387b1b951bd", "name": "59b22aa8-fbba-47e3-ab06-2534e76dd4d8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.799969889792979, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7055837837850989, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "24009d36-0cfe-4c27-8da0-4724252c4a08", "name": "f6c70340-8718-4978-baad-62577cbddc6d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b874b04-da0b-4a51-bc6f-b387b1b951bd"}}}]}, {"uuid": "d447dc1f-1c26-48c1-a2e3-570c6805d19c", "name": "load_p1rlv17403_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d61897a-cdac-4b4a-8812-8a8692a3d958"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "24009d36-0cfe-4c27-8da0-4724252c4a08"}}}}, {"uuid": "c1bd056d-22a3-4b0d-b9b6-30dab96ccba7", "name": "f5c00162-a7ca-4860-8b51-9d1298ee15be_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.799969889792979, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7055837837850989, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "af5e10e5-e0dc-4186-8e57-3edc6f6e524c", "name": "1efdaafa-c6c4-417f-8ea5-c2cf301c0219", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c1bd056d-22a3-4b0d-b9b6-30dab96ccba7"}}}]}, {"uuid": "764b567c-a4e5-4d1f-a784-9dda29a803e5", "name": "load_p1rlv17403_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d61897a-cdac-4b4a-8812-8a8692a3d958"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "af5e10e5-e0dc-4186-8e57-3edc6f6e524c"}}}}, {"uuid": "5c7e67f9-eb74-4072-bd15-aaf6c3dfadf1", "name": "982ef7b8-e286-439a-ae6c-c7188ec2f61a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2075389461119934, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3167249782629938, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7842d907-a8f8-4936-b8eb-c87fb3c1212a", "name": "37fe09d7-e1c6-460c-82f8-2ecbf0af9189", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5c7e67f9-eb74-4072-bd15-aaf6c3dfadf1"}}}]}, {"uuid": "e5ee68a5-e0bc-4a07-9fde-5f3a7730db64", "name": "load_p1rlv17405_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b50de14e-9a09-4f61-8998-0979f33b0d0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7842d907-a8f8-4936-b8eb-c87fb3c1212a"}}}}, {"uuid": "01b8414f-5666-464c-8250-fe528292c693", "name": "06d7800b-e9df-45f5-8302-dd539204b00e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2075389461119934, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3167249782629938, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b91c17c7-c950-4a98-bfcc-ac5bb84edf1e", "name": "c1b90e55-7f45-45e5-8a76-35326021fb6b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "01b8414f-5666-464c-8250-fe528292c693"}}}]}, {"uuid": "8a18a6a3-16ec-4cb1-a1b9-d836e6e65e29", "name": "load_p1rlv17405_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b50de14e-9a09-4f61-8998-0979f33b0d0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b91c17c7-c950-4a98-bfcc-ac5bb84edf1e"}}}}, {"uuid": "f588d3ad-fa76-478d-a91d-7bfce980b80b", "name": "3aaf73cf-4754-4d6a-a3af-42a02d25ccfd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2162240825393356, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.47013804182089236, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0be405d0-1eca-469c-80fc-ae833e8edba7", "name": "1c3b8c48-1d81-408e-94d1-45c355e21042", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f588d3ad-fa76-478d-a91d-7bfce980b80b"}}}]}, {"uuid": "a79e9642-e380-4811-94a3-a8e3ef214797", "name": "load_p1rlv17407_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65de341c-589f-4bf9-a708-26fcc94a6c0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0be405d0-1eca-469c-80fc-ae833e8edba7"}}}}, {"uuid": "39f99665-53c4-4897-8ee8-39b15c3c2d3d", "name": "90a1466b-6d62-48c2-820f-ff45af8d6778_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2162240825393356, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.47013804182089236, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ce0e992d-7170-43f0-b60a-0bc2db1ddd4f", "name": "5a438f1e-3ff8-47f7-a75c-272825c559c7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "39f99665-53c4-4897-8ee8-39b15c3c2d3d"}}}]}, {"uuid": "43efa592-e32e-40e2-bdd9-1b958d3c908d", "name": "load_p1rlv17407_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65de341c-589f-4bf9-a708-26fcc94a6c0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ce0e992d-7170-43f0-b60a-0bc2db1ddd4f"}}}}, {"uuid": "9de5024a-5503-4cee-bd35-09ef1bf4e580", "name": "7a92c937-bcf1-473f-aa95-62ac42cde235_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2816928104449037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4107329194522798, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "347d276f-d16b-46bf-99e7-1c5edbff94ab", "name": "aab4f704-c723-4488-9b50-f2debc755a5e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9de5024a-5503-4cee-bd35-09ef1bf4e580"}}}]}, {"uuid": "8350ccd7-b3f4-40f6-85b2-ccce48b7a5cd", "name": "load_p1rlv17415_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86b2527b-73c3-41c4-8ac2-7cb0e8bc2a7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "347d276f-d16b-46bf-99e7-1c5edbff94ab"}}}}, {"uuid": "b65a617e-98cd-4679-b909-11df11aba0ff", "name": "ce339973-1e65-4efc-8f33-b9f2860fe8bb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2816928104449037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4107329194522798, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "77228ec7-1d24-4bdb-933c-2eef13a771d5", "name": "37f2666b-debc-48db-b76c-446fbf120c0e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b65a617e-98cd-4679-b909-11df11aba0ff"}}}]}, {"uuid": "bd730a82-6946-45dd-849e-314b29a96e03", "name": "load_p1rlv17415_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86b2527b-73c3-41c4-8ac2-7cb0e8bc2a7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "77228ec7-1d24-4bdb-933c-2eef13a771d5"}}}}, {"uuid": "be257be2-6154-459a-9727-7434eab3ae9b", "name": "71b95e00-0e54-42ef-9fbb-ba7688857464_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.524011463187128, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7498872254128004, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d2e3f0b4-e35d-47aa-aa3c-057777b11819", "name": "16446f09-2dc2-43b1-abdd-bc9b03e70549", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "be257be2-6154-459a-9727-7434eab3ae9b"}}}]}, {"uuid": "aab56419-c994-43b3-acb6-4dc12758f78e", "name": "load_p1rlv17416_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64a56527-23a9-4229-aa25-f6a45f2187f4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d2e3f0b4-e35d-47aa-aa3c-057777b11819"}}}}, {"uuid": "9c6ca403-fd85-4b35-8892-013f17f967c1", "name": "dbeb95f5-8f49-47f6-9494-bd80cecb550e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.524011463187128, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7498872254128004, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fc931318-a8a4-493d-8371-27e3480f96e4", "name": "fea0aa3d-333a-4590-beec-7efce1279967", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9c6ca403-fd85-4b35-8892-013f17f967c1"}}}]}, {"uuid": "9361bc29-535d-4b5e-ab5c-b66b504f9f0c", "name": "load_p1rlv17416_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64a56527-23a9-4229-aa25-f6a45f2187f4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fc931318-a8a4-493d-8371-27e3480f96e4"}}}}, {"uuid": "9476faa4-9250-476c-8b03-68ef2566c80d", "name": "ee8ddc70-1c84-4dee-851c-1e58d1c6a2b7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.887268818021247, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.0124643291307467, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5031ad5c-b431-4be9-8d68-e0332e5699bb", "name": "52519b40-3f15-4cd1-b12a-27b5543ef4b5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9476faa4-9250-476c-8b03-68ef2566c80d"}}}]}, {"uuid": "c3fa75f3-7af0-4bd3-89e9-711d7614221f", "name": "load_p1rlv17417_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67003f0f-6690-469e-82c0-63949ee5241e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5031ad5c-b431-4be9-8d68-e0332e5699bb"}}}}, {"uuid": "1d75b5b1-a939-4899-9865-3e31ae1af64f", "name": "b9cbac1c-1576-4db1-a031-24fb551f1495_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.887268818021247, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.0124643291307467, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "85a852a4-0bd8-49ab-96ff-d748358a5287", "name": "b9af2d56-3844-4983-92db-339d49d0ef67", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1d75b5b1-a939-4899-9865-3e31ae1af64f"}}}]}, {"uuid": "14c2f474-05ed-47f4-a37f-e4c8361d4cb2", "name": "load_p1rlv17417_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67003f0f-6690-469e-82c0-63949ee5241e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "85a852a4-0bd8-49ab-96ff-d748358a5287"}}}}, {"uuid": "8cbbd0b1-9a4e-45dc-a1c9-b42a1661df65", "name": "3b3605a5-1da1-44ca-8aa7-b65e0fe15dd0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1219512592986662, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8685822493081499, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c8ae20d1-5b04-4bcc-a716-a7b254a720b4", "name": "7c39d8b1-a023-4667-9efd-77168170d85a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8cbbd0b1-9a4e-45dc-a1c9-b42a1661df65"}}}]}, {"uuid": "73aba28a-da22-4d76-8ef8-a166f2a20c31", "name": "load_p1rlv19574_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf457d88-958c-446a-9584-73be8c609bbe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c8ae20d1-5b04-4bcc-a716-a7b254a720b4"}}}}, {"uuid": "491cda37-a219-453c-bd7a-f818d86d7c69", "name": "d5bedc31-12ea-41fa-8b0e-3b77d6a70181_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1219512592986662, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8685822493081499, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "88ee732c-b169-4bbe-8ff7-5080f5252a9e", "name": "b827c4c3-d0e7-4405-a386-12643b337264", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "491cda37-a219-453c-bd7a-f818d86d7c69"}}}]}, {"uuid": "ebd41626-5df8-4131-9e56-6557ffebf1f1", "name": "load_p1rlv19574_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf457d88-958c-446a-9584-73be8c609bbe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "88ee732c-b169-4bbe-8ff7-5080f5252a9e"}}}}, {"uuid": "01b83cc5-088b-4535-b8c6-2f6d119cdc29", "name": "e9084385-43f4-4dcc-a766-b59a6f16cf00_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.817160338362793, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.8654854383625104, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2e5ea7d6-5d3e-4ab2-a2a8-f4b47aceb960", "name": "434ed16a-7e6f-4fc1-9fab-5afd87d35143", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "01b83cc5-088b-4535-b8c6-2f6d119cdc29"}}}]}, {"uuid": "ff4b85f9-f026-4da1-bb90-b0daebe67df4", "name": "load_p1rlv19608_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f917b142-d59f-4a51-8c3b-913feb53411d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2e5ea7d6-5d3e-4ab2-a2a8-f4b47aceb960"}}}}, {"uuid": "fc108728-c806-46c7-9d22-68ded33066cc", "name": "c02ebb55-f9f3-468b-9fc6-b92bc289e1f3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.817160338362793, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.8654854383625104, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "31ed6c2a-ae9e-4a5e-aa55-bef73c08d0d7", "name": "c516f3fc-4e7c-484f-9646-592d6aba09da", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fc108728-c806-46c7-9d22-68ded33066cc"}}}]}, {"uuid": "cd9175ba-3277-41e9-9fe7-929229dfdf54", "name": "load_p1rlv19608_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f917b142-d59f-4a51-8c3b-913feb53411d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "31ed6c2a-ae9e-4a5e-aa55-bef73c08d0d7"}}}}, {"uuid": "861b9adc-05fe-4dee-ae1f-f543c31f61eb", "name": "48772389-aa31-4394-b8e2-a2d7dccbce94_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.931347600748843, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.97768534997531, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cf3c100b-93d4-4c17-8d10-cdb0d190a302", "name": "e2672745-f7ac-400b-b48c-7b1c6bc1726e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "861b9adc-05fe-4dee-ae1f-f543c31f61eb"}}}]}, {"uuid": "3eead1e5-07f0-4ee7-84c6-07dcd4f130b0", "name": "load_p1rlv19610_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "813f887e-6807-4ffc-90bf-bd30cde9a9df"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cf3c100b-93d4-4c17-8d10-cdb0d190a302"}}}}, {"uuid": "01550101-b582-41aa-ae25-30f44134001d", "name": "28fec7d8-95f1-4a68-b4d3-a15cbfab2792_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.931347600748843, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.97768534997531, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3e1afdcd-ce9c-4989-8c68-15db2c7114bf", "name": "8255ef47-9ab6-4f7d-b7e6-8ef9d13464aa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "01550101-b582-41aa-ae25-30f44134001d"}}}]}, {"uuid": "c27da2d6-a9d3-47c2-9056-b49f5f2fff1f", "name": "load_p1rlv19610_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "813f887e-6807-4ffc-90bf-bd30cde9a9df"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3e1afdcd-ce9c-4989-8c68-15db2c7114bf"}}}}, {"uuid": "5985b63c-147a-4326-bafe-41ba848dea30", "name": "8638f04b-97f9-478b-8801-4cc733147fde_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5877230897388055, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4388767979233367, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "795a41ee-4f11-4851-bb52-ec20deb75787", "name": "52439e00-1f5a-4a03-badb-53c010a26c68", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5985b63c-147a-4326-bafe-41ba848dea30"}}}]}, {"uuid": "1296b321-b4be-4bed-8bf8-b44a0438459a", "name": "load_p1rlv19616_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be1b9922-2426-4726-9e5a-bcd33f444b57"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "795a41ee-4f11-4851-bb52-ec20deb75787"}}}}, {"uuid": "2d397e2e-5344-4333-820f-7894baf42aef", "name": "79d92001-bc92-4823-9e1c-851734be8689_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5877230897388055, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4388767979233367, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c32a656-137e-4d99-97c7-0e842dae33e9", "name": "80876c3d-d8c5-47d7-ae76-e3a9ab056fa7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2d397e2e-5344-4333-820f-7894baf42aef"}}}]}, {"uuid": "2a53dcc4-8c69-4632-b1af-ef95e2bbb525", "name": "load_p1rlv19616_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be1b9922-2426-4726-9e5a-bcd33f444b57"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c32a656-137e-4d99-97c7-0e842dae33e9"}}}}, {"uuid": "3ffd9aeb-ffaf-4c77-988f-21934028f3fb", "name": "a70da804-57f4-494b-905e-f44e64ad7b5f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.925260736902077, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.726135012516628, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "00c79078-4ffb-4f0f-855a-ca8dc265cd1e", "name": "272f4a4f-b213-4932-b85f-8e9af0e5892c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3ffd9aeb-ffaf-4c77-988f-21934028f3fb"}}}]}, {"uuid": "c74b9f6c-f9ba-4508-a774-4728d5a2ee91", "name": "load_p1rlv19640_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e90f763-682e-4771-976c-9cd736b72133"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "00c79078-4ffb-4f0f-855a-ca8dc265cd1e"}}}}, {"uuid": "c23552af-3ba4-41b2-b568-a394025c6c76", "name": "62b10e40-2852-42e5-9e8e-a772162d2bc9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.925260736902077, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.726135012516628, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6bed2d9c-e8f4-4ae5-a8c9-40896dc8e08e", "name": "3f9169a6-f8b4-41a8-b7de-17d6058ae1ac", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c23552af-3ba4-41b2-b568-a394025c6c76"}}}]}, {"uuid": "a05f7e5d-2673-4d13-a1c9-eef49f17ca26", "name": "load_p1rlv19640_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e90f763-682e-4771-976c-9cd736b72133"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6bed2d9c-e8f4-4ae5-a8c9-40896dc8e08e"}}}}, {"uuid": "56027744-baa0-42d5-8b68-edfd1bf583b5", "name": "bd45c2ed-6be0-4f81-bd1e-36effbf40114_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3571348598185444, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7897285261495656, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b736c69d-5be1-415c-a425-ec5654f8f039", "name": "a23be684-93ce-4cd6-becf-d7a52813160e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "56027744-baa0-42d5-8b68-edfd1bf583b5"}}}]}, {"uuid": "592c8ae4-e706-4b2d-a646-93ff39996f17", "name": "load_p1rlv19643_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f0e181a-fa89-4c5d-a1cb-6080f91331da"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b736c69d-5be1-415c-a425-ec5654f8f039"}}}}, {"uuid": "c814fe75-4519-48fa-ad9a-2661876cb633", "name": "1980c37a-587b-4e2b-9f3f-d44f334738a3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3571348598185444, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7897285261495656, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fe957262-5f7c-47d7-90b5-8f04f058c6e9", "name": "75889327-7bc0-4064-96ce-be904f063c04", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c814fe75-4519-48fa-ad9a-2661876cb633"}}}]}, {"uuid": "b694819c-01b7-4cb7-a06a-d517d4bd8c90", "name": "load_p1rlv19643_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f0e181a-fa89-4c5d-a1cb-6080f91331da"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fe957262-5f7c-47d7-90b5-8f04f058c6e9"}}}}, {"uuid": "84877362-3505-4637-8a0a-cdac5d81880b", "name": "e9b04e35-cdbd-4958-a7bb-35daa42ee745_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.354599726773856, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.636709731909327, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50de177e-e986-4594-8655-d4e28e80b481", "name": "3645d95c-8b84-4396-820b-2a6475d87400", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "84877362-3505-4637-8a0a-cdac5d81880b"}}}]}, {"uuid": "de328b1d-637f-4e00-8587-c7674fc4b3e2", "name": "load_p1rlv19645_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7efbb32-55d4-409b-a37f-bf01d0620d40"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50de177e-e986-4594-8655-d4e28e80b481"}}}}, {"uuid": "1c560954-9a26-45dc-824c-d2fd2586fc48", "name": "41a3ab7d-0a41-4f58-b572-b432521ee0df_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.354599726773856, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.636709731909327, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d50067a1-8c81-4f68-954a-fc8fab41c905", "name": "e0e37918-3471-4814-afda-69fb3338c899", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1c560954-9a26-45dc-824c-d2fd2586fc48"}}}]}, {"uuid": "db057238-fe08-440a-8938-d471bbdb491b", "name": "load_p1rlv19645_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7efbb32-55d4-409b-a37f-bf01d0620d40"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d50067a1-8c81-4f68-954a-fc8fab41c905"}}}}, {"uuid": "5cfa9f24-fb2e-49eb-9407-fed20b015f3b", "name": "d379a36f-5756-47b3-8ca0-a98f811e3598_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1763634802125313, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8050824744595734, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5c1a0340-3f57-4656-98ff-967ad63d2363", "name": "73089cdc-992d-4e0e-91de-9f8dea577196", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5cfa9f24-fb2e-49eb-9407-fed20b015f3b"}}}]}, {"uuid": "b5a20c0a-b9dd-4aba-8196-cf6292d1eb80", "name": "load_p1rlv19683_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19894180-0890-4585-b4e2-55500af3c41a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5c1a0340-3f57-4656-98ff-967ad63d2363"}}}}, {"uuid": "20fee792-37d4-4207-9023-dd663ac217a8", "name": "d4b61c7e-2966-4cd3-86b5-207b3da141d7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1763634802125313, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8050824744595734, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a455b71-a883-4b54-abf0-167c0928995b", "name": "4d363972-a584-4fc8-8320-0827e3556b23", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "20fee792-37d4-4207-9023-dd663ac217a8"}}}]}, {"uuid": "36f8c773-9a3e-4bae-b0db-fc25a31d0d23", "name": "load_p1rlv19683_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19894180-0890-4585-b4e2-55500af3c41a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a455b71-a883-4b54-abf0-167c0928995b"}}}}, {"uuid": "98cab855-e394-4444-8423-672ff982150f", "name": "b1b5f5e3-d8d1-4f6f-8b7b-4b1c42aaf35b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7055277650263714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24030088917661724, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a85f6b6-de93-4523-9c7d-1ace1ea283ec", "name": "aae51e6e-b2e7-4c5f-b5d0-d72d3b04a775", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "98cab855-e394-4444-8423-672ff982150f"}}}]}, {"uuid": "2adf5309-aace-4f00-bed6-ed4e7bf836ce", "name": "load_p1rlv37689_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f827fe9e-1ffe-456c-a57b-c3374aef8ad8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0a85f6b6-de93-4523-9c7d-1ace1ea283ec"}}}}, {"uuid": "c87318a7-0a2d-4353-959c-35db301a0857", "name": "2d96a672-ef1f-4027-9e52-530ec682c50e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7055277650263714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24030088917661724, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8ec9c9b7-ab9f-491f-9c1e-32faf27ddc30", "name": "c7f10edc-5d68-4589-89e7-b23d4b7e966b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c87318a7-0a2d-4353-959c-35db301a0857"}}}]}, {"uuid": "858d9eec-d859-4213-9573-c97d163c8c71", "name": "load_p1rlv37689_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f827fe9e-1ffe-456c-a57b-c3374aef8ad8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8ec9c9b7-ab9f-491f-9c1e-32faf27ddc30"}}}}, {"uuid": "86aabb6c-bae3-4a95-8565-6a0e0c767b23", "name": "0404afe2-c99a-439e-bec4-76d53cb6dc65_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.991433457795887, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5982568468826307, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6b10a72c-3057-428c-b0c4-5cd3762cd47c", "name": "623fd40d-3aab-4ef4-96dc-6464c1c13bff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "86aabb6c-bae3-4a95-8565-6a0e0c767b23"}}}]}, {"uuid": "2b4781d6-4030-4d0b-9b8d-26f217c668e9", "name": "load_p1rlv37691_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da3cd593-6f05-41ba-9609-f6f1e307e998"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6b10a72c-3057-428c-b0c4-5cd3762cd47c"}}}}, {"uuid": "5493cb3e-8215-40c5-9d74-817a0fa2af4a", "name": "7dd65da8-bc6e-404d-9358-d414e807e6df_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.991433457795887, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5982568468826307, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b0f43b4f-d9a9-4d34-bf7f-629916a21f88", "name": "c48de185-469d-4a88-bc12-b03777829130", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5493cb3e-8215-40c5-9d74-817a0fa2af4a"}}}]}, {"uuid": "4561c13f-6bf9-4990-a9e7-23a58b2df2e8", "name": "load_p1rlv37691_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da3cd593-6f05-41ba-9609-f6f1e307e998"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b0f43b4f-d9a9-4d34-bf7f-629916a21f88"}}}}, {"uuid": "c77b0fe6-fd6d-423f-9782-f42f4e139504", "name": "3d48ae85-0040-459a-9849-d48248b838ae_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9233060787231575, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.431469772224645, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8b877d53-04ab-4102-874b-cb892fa21f1f", "name": "0011e870-a629-4810-b98a-1dcd94344fa9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c77b0fe6-fd6d-423f-9782-f42f4e139504"}}}]}, {"uuid": "c4eccd81-0ac9-473f-b1b0-50cd3a52c637", "name": "load_p1rlv37703_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01c9efda-0adf-4932-8f54-2938964371d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8b877d53-04ab-4102-874b-cb892fa21f1f"}}}}, {"uuid": "83dfc415-cd1b-40d8-ad51-de06357e06e5", "name": "fbc35b91-860a-4f01-aeea-64536975e4c5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9233060787231575, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.431469772224645, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0691e60b-1d86-4f19-b917-91d72314e28f", "name": "9e6c4158-1c0b-4ddb-917a-70f78209c62b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "83dfc415-cd1b-40d8-ad51-de06357e06e5"}}}]}, {"uuid": "2653101b-973b-4458-840e-2d2e1856bb38", "name": "load_p1rlv37703_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01c9efda-0adf-4932-8f54-2938964371d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0691e60b-1d86-4f19-b917-91d72314e28f"}}}}, {"uuid": "1a073c58-9dd9-412e-a2fa-dff5fafef051", "name": "f58579e3-c492-435b-a453-142e6abb9e9c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5500863393357383, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3576036143879098, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a7e703dd-da55-44a3-9e7c-14d344c4d2fc", "name": "62ec24a3-0acd-41eb-ba42-3ffd327e1896", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1a073c58-9dd9-412e-a2fa-dff5fafef051"}}}]}, {"uuid": "cc3f5d8c-a0ce-49d0-920a-f2fa6fddc0a1", "name": "load_p1rlv37710_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38bda697-2888-467e-bab0-62896a62503f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a7e703dd-da55-44a3-9e7c-14d344c4d2fc"}}}}, {"uuid": "b7358bdb-3dff-4dd8-a8b7-700381fa7043", "name": "ccf907b8-6bd1-45fe-bafe-b26b9ecbaf16_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5500863393357383, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3576036143879098, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "394f38b0-a2d4-48fe-b92e-e2df4d1a8720", "name": "1195b5b4-2083-4043-a818-76e24534b81d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b7358bdb-3dff-4dd8-a8b7-700381fa7043"}}}]}, {"uuid": "534db35e-7b40-4f9d-a0fd-a97b5e54190a", "name": "load_p1rlv37710_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38bda697-2888-467e-bab0-62896a62503f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "394f38b0-a2d4-48fe-b92e-e2df4d1a8720"}}}}, {"uuid": "6f56ae76-1918-43f7-89a3-77b983b8bb29", "name": "b722e849-b111-4203-855b-f505ba11eb7b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2045141672666357, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3046267940472902, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b364fae8-133e-49f4-b5a3-761aad2becc9", "name": "f4ac8e2a-7c9b-4795-959b-cd96e9b89fb5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6f56ae76-1918-43f7-89a3-77b983b8bb29"}}}]}, {"uuid": "9e3f743f-e24d-486d-85ae-927080312cd0", "name": "load_p1rlv37732_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d998a0-628e-4009-a6c8-07af906f6d43"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b364fae8-133e-49f4-b5a3-761aad2becc9"}}}}, {"uuid": "ebe3272a-9772-4c74-876b-eeca1b7cebc0", "name": "6fecf92d-9e03-4f24-9d19-d5a6046488d2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2045141672666357, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3046267940472902, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cc9452be-8e52-4b91-96d8-092b3a3c5c39", "name": "ac7cf685-62c6-47f5-af2f-2c0d68dd981a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ebe3272a-9772-4c74-876b-eeca1b7cebc0"}}}]}, {"uuid": "f94b41ae-f7e2-45a9-8982-d1f2a4c17754", "name": "load_p1rlv37732_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d998a0-628e-4009-a6c8-07af906f6d43"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cc9452be-8e52-4b91-96d8-092b3a3c5c39"}}}}, {"uuid": "c2393e52-03c1-41ff-a32e-c1ac1d17ba93", "name": "776d405b-dd5a-49ab-aeea-98dcac4f6649_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.106965589535082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4202201192794711, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2ee241d8-7db3-4353-858e-63fdc838be4d", "name": "14dad654-46fe-471d-ad8d-bbf20a170c22", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c2393e52-03c1-41ff-a32e-c1ac1d17ba93"}}}]}, {"uuid": "15228525-13a8-4f68-9e9a-afeb20048a91", "name": "load_p1rlv37776_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b24da1e-9a6e-4545-9ad4-a9f0e9675fd1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2ee241d8-7db3-4353-858e-63fdc838be4d"}}}}, {"uuid": "a0ed8fb5-9e42-4c0e-873b-cf78be7f20be", "name": "372a9612-a533-4703-8742-e10f26fd3696_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.106965589535082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4202201192794711, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e80daaf8-3d12-4628-8de2-e4372eedada7", "name": "121fa53a-e7f5-4720-8f34-227d39a96dd8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a0ed8fb5-9e42-4c0e-873b-cf78be7f20be"}}}]}, {"uuid": "306bb777-27dc-416c-96b8-0447cad5164d", "name": "load_p1rlv37776_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b24da1e-9a6e-4545-9ad4-a9f0e9675fd1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e80daaf8-3d12-4628-8de2-e4372eedada7"}}}}, {"uuid": "d93d7ca7-c729-4125-bfd0-2f82fa5a471f", "name": "9fd20af8-340a-405a-9370-74c501099235_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2167250892906645, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5534364726692191, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "734a6bb3-dae1-4e22-be5d-527c73a6540a", "name": "2b66fee4-6134-478a-b846-d39ac761d1b5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d93d7ca7-c729-4125-bfd0-2f82fa5a471f"}}}]}, {"uuid": "a68c442d-21fb-41e6-95df-690b8cd20ab7", "name": "load_p1rlv37778_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5aaed5d-8312-4707-a047-634e433bf49f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "734a6bb3-dae1-4e22-be5d-527c73a6540a"}}}}, {"uuid": "139fc5dd-4ca9-4a4e-82e3-8b80b42bb469", "name": "9c3a510f-8e0a-4448-bc99-f8bae25c5d9f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2167250892906645, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5534364726692191, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "86030c64-9459-40d0-b8e1-71d5ae1714d0", "name": "924ac7c7-beb4-4989-b768-0880dcd98530", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "139fc5dd-4ca9-4a4e-82e3-8b80b42bb469"}}}]}, {"uuid": "e486422a-1d43-4a96-bc12-12ab56910f1a", "name": "load_p1rlv37778_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5aaed5d-8312-4707-a047-634e433bf49f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "86030c64-9459-40d0-b8e1-71d5ae1714d0"}}}}, {"uuid": "74ee0370-3552-4051-b115-3d9a4a803ca9", "name": "1d4e7e8d-41c6-4b7c-9fe1-c52d8786e85b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.902887215219663, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.111231385342157, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4bb58eb7-9b1b-49ed-be9f-dd90df587a32", "name": "5255aa2d-5cfc-4751-b610-3faf2f23d324", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "74ee0370-3552-4051-b115-3d9a4a803ca9"}}}]}, {"uuid": "d440d345-0229-4755-b7a7-bd7e8c8d8d62", "name": "load_p1rlv37782_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d7181ee-ef64-4ded-b619-00ac09d55bf5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4bb58eb7-9b1b-49ed-be9f-dd90df587a32"}}}}, {"uuid": "2f33d06a-54a0-48c0-bfcf-aec8a3f39520", "name": "45c722ba-3606-42aa-801a-02dbe9f10be2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.902887215219663, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.111231385342157, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "35d7c016-72d7-473e-b225-83d5a38ed0ad", "name": "086f70d3-b36c-4f63-bbbd-4ecc9a894bab", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2f33d06a-54a0-48c0-bfcf-aec8a3f39520"}}}]}, {"uuid": "5c8f4d9e-dd5b-4d8a-be06-f85681e95b9d", "name": "load_p1rlv37782_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d7181ee-ef64-4ded-b619-00ac09d55bf5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "35d7c016-72d7-473e-b225-83d5a38ed0ad"}}}}, {"uuid": "0e1bf61f-7a87-4871-aa7b-22c7e79ee653", "name": "79649c1e-e16e-4278-89ec-21d847472dda_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9179777962446224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3481400399277513, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a2723ae6-1a19-4f11-bd92-98787ee42be2", "name": "5d77a13a-856c-45bf-8e0f-19b712c6e3a3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0e1bf61f-7a87-4871-aa7b-22c7e79ee653"}}}]}, {"uuid": "8d154921-728c-48a5-b4a7-bcc8c97708bb", "name": "load_p1rlv38046_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10be49a0-301a-4c7e-8ab7-49c14e483079"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a2723ae6-1a19-4f11-bd92-98787ee42be2"}}}}, {"uuid": "ed625f7a-68a1-410e-b8df-84452f66f6b8", "name": "59123853-e958-47af-b720-f91604eef741_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9179777962446224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3481400399277513, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8faee505-53f5-47af-9023-87d9ff1df03b", "name": "9eef8f72-c435-49be-afdb-c937371c9361", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ed625f7a-68a1-410e-b8df-84452f66f6b8"}}}]}, {"uuid": "4af84904-a5e3-4004-9f0c-6ed1b7231689", "name": "load_p1rlv38046_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10be49a0-301a-4c7e-8ab7-49c14e483079"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8faee505-53f5-47af-9023-87d9ff1df03b"}}}}, {"uuid": "1df809e0-3274-4384-9c54-d21577f02b53", "name": "4938b5d6-73b1-485a-9b79-9c1f12c4f1a8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.567401274738218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6497123013243786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5b46ccb1-8f48-4fbc-9c82-e415a0ad9d07", "name": "42eb82be-9e48-4f8c-b18a-eeadcad25a56", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1df809e0-3274-4384-9c54-d21577f02b53"}}}]}, {"uuid": "dfde6f3a-b403-417f-8c61-c644f709f0d3", "name": "load_p1rlv38047_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0935a86b-b9fb-4058-8381-a41f67d6c9dd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5b46ccb1-8f48-4fbc-9c82-e415a0ad9d07"}}}}, {"uuid": "f5f4bd81-a812-4107-ac47-065bed44c722", "name": "fc72493e-0be6-4f75-9cb3-001f243338b0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.567401274738218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6497123013243786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7aee0163-ee99-4c05-95b5-44654457a3cc", "name": "f08bd294-0d21-416b-8f98-1b1cc7cdc5a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f5f4bd81-a812-4107-ac47-065bed44c722"}}}]}, {"uuid": "f4651df5-82c7-4ab0-bd4e-5137e3353b1f", "name": "load_p1rlv38047_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0935a86b-b9fb-4058-8381-a41f67d6c9dd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7aee0163-ee99-4c05-95b5-44654457a3cc"}}}}, {"uuid": "a01cc709-6a93-436c-be8f-404385b978ed", "name": "0341cac6-411d-407b-bb85-f0594adc83fc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7055277650263714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24030088917661724, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "57c21e44-3c60-41c7-bf81-b13fffe7fa16", "name": "cf4d6a99-9857-443c-99c3-64407ec0a059", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a01cc709-6a93-436c-be8f-404385b978ed"}}}]}, {"uuid": "bdfa7b18-fee2-4bf2-9188-13278de4f43f", "name": "load_p1rlv38048_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5da7ff68-5f4c-4d56-88fc-7736df03c0bf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "57c21e44-3c60-41c7-bf81-b13fffe7fa16"}}}}, {"uuid": "f1942386-e836-4587-bcf8-0c1144583744", "name": "896c9f6e-9acb-4270-a40c-35a23d98683d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7055277650263714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24030088917661724, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4227af12-679c-41e9-9c94-3eed1c08f7c6", "name": "a47147a2-c190-4c6e-985d-d08f6c5a3735", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f1942386-e836-4587-bcf8-0c1144583744"}}}]}, {"uuid": "e924c390-81b4-455c-9168-e1bd8492dbef", "name": "load_p1rlv38048_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5da7ff68-5f4c-4d56-88fc-7736df03c0bf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4227af12-679c-41e9-9c94-3eed1c08f7c6"}}}}, {"uuid": "2c6e618c-9bd8-4a23-907b-e1b1054dc113", "name": "45e67a46-945d-46bc-a0e1-2da48c439ab3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3461402320099836, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.810674183062217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4a1be0c9-b577-4e0b-af32-43b02a73f6c3", "name": "71d6dfc0-198c-4a85-bcd4-d01618dd45d9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2c6e618c-9bd8-4a23-907b-e1b1054dc113"}}}]}, {"uuid": "1ad5c597-4a47-4353-9489-946f00e9c421", "name": "load_p1rlv38050_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cafc6c03-240d-499d-a3d8-983b554dd007"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4a1be0c9-b577-4e0b-af32-43b02a73f6c3"}}}}, {"uuid": "f4508784-7f40-4dc9-ad9d-315d99b5c956", "name": "2d00b450-e4c5-4f89-b86e-a120c04dcc5c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3461402320099836, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.810674183062217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "302ac0e1-a6d5-4edc-9313-27fe87f5939b", "name": "9dd76531-cda9-4ed8-a169-0315ae4c992e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f4508784-7f40-4dc9-ad9d-315d99b5c956"}}}]}, {"uuid": "cf8abd4e-54cb-4645-9afe-f58ba3325547", "name": "load_p1rlv38050_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cafc6c03-240d-499d-a3d8-983b554dd007"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "302ac0e1-a6d5-4edc-9313-27fe87f5939b"}}}}, {"uuid": "2db1953f-8ac5-4836-9b25-02934a423246", "name": "3fefc103-bd15-49d7-87e5-56ada79cf4ce_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5229589832640044, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3359880712066463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3a6e37bd-3209-44ad-9074-aa81b0812b1d", "name": "324d4778-60b7-42fc-9066-ef23bde6e01f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2db1953f-8ac5-4836-9b25-02934a423246"}}}]}, {"uuid": "14f17525-bfe4-475a-a678-6316279102a6", "name": "load_p1rlv38052_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9db6122d-1e51-46ac-9cea-ac436e189cd8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3a6e37bd-3209-44ad-9074-aa81b0812b1d"}}}}, {"uuid": "00387573-1e1f-4645-9f4f-ec988a7e403d", "name": "fc70e151-175c-4ed3-b3d0-797ba65b6651_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5229589832640044, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3359880712066463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7df7a2f1-c087-4459-b464-df267e33d2ac", "name": "0170b546-2ac5-4288-bcaf-bbd96c66050c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "00387573-1e1f-4645-9f4f-ec988a7e403d"}}}]}, {"uuid": "aa000fe1-41ac-4646-98a4-d4d129240649", "name": "load_p1rlv38052_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9db6122d-1e51-46ac-9cea-ac436e189cd8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7df7a2f1-c087-4459-b464-df267e33d2ac"}}}}, {"uuid": "ddba05ec-071b-41c5-8bb7-5c3b8a924a32", "name": "4d7fe478-3369-4513-8f00-61cbffbd24de_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6912886909314806, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4972799611827758, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "49edfd08-7cb8-48ad-97ae-f3c8d7f24eae", "name": "069b9506-9dda-4954-a57a-b0e605bcff0b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ddba05ec-071b-41c5-8bb7-5c3b8a924a32"}}}]}, {"uuid": "37ee0175-44d4-4a8b-b904-22f3be239243", "name": "load_p1rlv38414_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a25b3511-86cf-404e-944f-273d3f94c05a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "49edfd08-7cb8-48ad-97ae-f3c8d7f24eae"}}}}, {"uuid": "72dc9b8f-422e-469c-8384-57ec67ffd3dd", "name": "178b63c7-ed29-45ce-b987-87d42a938880_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6912886909314806, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4972799611827758, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e05fa500-dcfe-4eb0-a404-e10a89b8bfb5", "name": "8f8ed8fa-059c-467b-919c-368f708c9254", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72dc9b8f-422e-469c-8384-57ec67ffd3dd"}}}]}, {"uuid": "03aafef1-9f4a-40c0-ab85-7f1c8f3ca2d4", "name": "load_p1rlv38414_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a25b3511-86cf-404e-944f-273d3f94c05a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e05fa500-dcfe-4eb0-a404-e10a89b8bfb5"}}}}, {"uuid": "922dde16-f073-4cba-89cd-a40353cca45c", "name": "ebf5b4b2-e731-4331-be5b-f322820089ad_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6878718453957338, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9600190343762964, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8cebfff3-32a0-4c4c-a852-dfa1f641987d", "name": "bda622e7-45b3-4ff7-867c-481d3a79b9c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "922dde16-f073-4cba-89cd-a40353cca45c"}}}]}, {"uuid": "51a15ddd-7db2-4da1-a796-936153825f09", "name": "load_p1rlv38417_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "201112bb-3dc7-4a15-9af6-155626ac1ae5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8cebfff3-32a0-4c4c-a852-dfa1f641987d"}}}}, {"uuid": "2c8a9662-1226-4af2-aecf-f8cd908d8f43", "name": "22ef792c-56e0-4d18-9df7-f59e6a870b97_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6878718453957338, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9600190343762964, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1605947c-01ca-43fe-af9e-54f7a5d541dc", "name": "26506bde-e643-4406-af63-c70ff8a8c062", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2c8a9662-1226-4af2-aecf-f8cd908d8f43"}}}]}, {"uuid": "e24cf5b6-9e5c-424f-9d57-f2710d51ee80", "name": "load_p1rlv38417_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "201112bb-3dc7-4a15-9af6-155626ac1ae5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1605947c-01ca-43fe-af9e-54f7a5d541dc"}}}}, {"uuid": "40bee9c3-6f8e-4820-9b82-c561e4dd8cd5", "name": "b3e8f28b-546c-4b70-ae2f-cbfd56534bb2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1e9537dc-a42d-4f9d-82f4-d287f4a35c2f", "name": "d1e6d7cd-2d4c-443f-a229-feddf0d9f0f7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "40bee9c3-6f8e-4820-9b82-c561e4dd8cd5"}}}]}, {"uuid": "00fe2b7b-033a-492a-8759-3b3af439d698", "name": "load_p1rlv38419_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6e4595c-0ad9-4501-b86f-c559917d4b86"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1e9537dc-a42d-4f9d-82f4-d287f4a35c2f"}}}}, {"uuid": "4b9d5d48-e313-4aaa-b53d-24fccd78187f", "name": "a2179bea-f33a-48c1-bc9f-61ae16e84437_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6e0f2455-0479-4f0c-a49f-27a274acd027", "name": "e69754bc-3284-4f21-aca4-5b9887bc5486", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4b9d5d48-e313-4aaa-b53d-24fccd78187f"}}}]}, {"uuid": "679b326d-63be-4613-8983-a59fc0fa4c32", "name": "load_p1rlv38419_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6e4595c-0ad9-4501-b86f-c559917d4b86"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6e0f2455-0479-4f0c-a49f-27a274acd027"}}}}, {"uuid": "5e332f41-3784-41b1-bdd5-1b456b231b94", "name": "223ee756-b983-49a0-a8d7-5da73d7a9854_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4437884187508536, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6647073432497462, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "08881b61-ad46-4516-8ea2-fd49b9927b0d", "name": "207cf4ad-47c0-4517-9b0a-4cff9241790a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5e332f41-3784-41b1-bdd5-1b456b231b94"}}}]}, {"uuid": "8e95af66-31ca-450a-9aca-8e106892bc76", "name": "load_p1rlv38535_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0764c32-4f46-473a-9a72-cccc45ae28d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "08881b61-ad46-4516-8ea2-fd49b9927b0d"}}}}, {"uuid": "f31c8764-bc97-4b4f-9cde-1bff89246fc5", "name": "9a7854f0-9599-41e2-9500-3224aa894639_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4437884187508536, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6647073432497462, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ca22f49a-9bb5-4730-9763-f1547662a06c", "name": "31ed3613-f5be-4a5d-8fd7-4c68c8981c8f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f31c8764-bc97-4b4f-9cde-1bff89246fc5"}}}]}, {"uuid": "58393dd1-90b2-4398-bbe7-3f69c8f25e00", "name": "load_p1rlv38535_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0764c32-4f46-473a-9a72-cccc45ae28d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ca22f49a-9bb5-4730-9763-f1547662a06c"}}}}, {"uuid": "d454f0ed-1569-430e-a940-9d11311f731b", "name": "f04f697d-37ba-4d73-95d1-f96a5f7ecc37_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5614762943111877, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5370528430833497, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d0dc1e81-ba82-445e-b840-c4eb3368537d", "name": "65336003-5aff-4e73-9c30-20dfe7f3ad78", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d454f0ed-1569-430e-a940-9d11311f731b"}}}]}, {"uuid": "d8642f17-a073-4fc4-b101-e1bde0153ea3", "name": "load_p1rlv38536_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ff930f9-63f0-4cab-b74a-3db7eb99f9eb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d0dc1e81-ba82-445e-b840-c4eb3368537d"}}}}, {"uuid": "5f99d8e8-222c-428c-b58d-bedefaed8cff", "name": "34fb25d7-73ca-40bd-a16e-924046d35039_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5614762943111877, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5370528430833497, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7717126d-86db-447c-b9ee-e99387684c27", "name": "7a840a3c-59e7-403f-850b-0ed4f56e8cda", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5f99d8e8-222c-428c-b58d-bedefaed8cff"}}}]}, {"uuid": "f132d970-074f-4152-9cf2-133e45e0e521", "name": "load_p1rlv38536_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ff930f9-63f0-4cab-b74a-3db7eb99f9eb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7717126d-86db-447c-b9ee-e99387684c27"}}}}, {"uuid": "70674b72-a9af-4244-a49c-a946d23cd5d4", "name": "bceb8436-c19d-430a-8583-8e705606fc45_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.025577912376512, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6479907691217454, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4b2e37ea-aabf-48dc-8e2b-7f18d626f96c", "name": "e3309c21-0a36-47e8-86bb-7cc362d97460", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "70674b72-a9af-4244-a49c-a946d23cd5d4"}}}]}, {"uuid": "80296163-decf-4c33-9c29-f346c1e8894b", "name": "load_p1rlv38638_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a3851f7-2dd3-447b-918f-7a8c954f21d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4b2e37ea-aabf-48dc-8e2b-7f18d626f96c"}}}}, {"uuid": "5f88a3fa-aabe-40f5-98e8-b4c86b5127f2", "name": "14f0875b-323b-4763-accf-cc6bcf457c6a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.025577912376512, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6479907691217454, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "821814a0-8f88-41d6-833d-160deb4cc4d3", "name": "ecc2ace6-5ab0-40de-9f3b-4ca05e791e59", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5f88a3fa-aabe-40f5-98e8-b4c86b5127f2"}}}]}, {"uuid": "23e8e6e7-c753-4b47-b081-311d3606c52a", "name": "load_p1rlv38638_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a3851f7-2dd3-447b-918f-7a8c954f21d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "821814a0-8f88-41d6-833d-160deb4cc4d3"}}}}, {"uuid": "e0395ca4-5b57-46fa-a42b-a3439c90eed9", "name": "6be7f68a-6e69-4489-b82d-f3b9a8918363_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9441129975170507, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3957038740694923, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f9262875-977b-478e-9cf8-77465f491ce9", "name": "6be7f68a-6e69-4489-b82d-f3b9a8918363_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9441129975170507, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3957038740694923, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8ff257d5-f8f4-44d2-bef4-ea55e776524c", "name": "6be7f68a-6e69-4489-b82d-f3b9a8918363_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9441129975170507, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3957038740694923, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "636fdd99-94b2-4fd8-92ef-dd9197f93ae7", "name": "e70df2d2-9cd0-4d1a-944e-4f0ab30a0962", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e0395ca4-5b57-46fa-a42b-a3439c90eed9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f9262875-977b-478e-9cf8-77465f491ce9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ff257d5-f8f4-44d2-bef4-ea55e776524c"}}}]}, {"uuid": "e184e575-2f3d-45e6-be66-31e4057bd428", "name": "load_p1rlv12518", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72f659b6-d302-4887-a2f6-1a477ad3324c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "636fdd99-94b2-4fd8-92ef-dd9197f93ae7"}}}}, {"uuid": "c5214aa9-c215-401b-9460-cc4c162c5548", "name": "b3583558-bd86-450e-bf77-a42b5aedf621_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3777678420633588, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24446119545004893, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0735b653-7b01-4570-a36e-ceb8ba68e689", "name": "b3583558-bd86-450e-bf77-a42b5aedf621_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3777678420633588, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24446119545004893, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ea3aef81-1188-4650-b68c-5f1a6b83a171", "name": "b3583558-bd86-450e-bf77-a42b5aedf621_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3777678420633588, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24446119545004893, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "afe2c2f2-60ae-474a-84c9-2fb36790d4c8", "name": "26e5f4ef-16f1-46f8-9a3e-9b9ceea7fc24", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c5214aa9-c215-401b-9460-cc4c162c5548"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0735b653-7b01-4570-a36e-ceb8ba68e689"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ea3aef81-1188-4650-b68c-5f1a6b83a171"}}}]}, {"uuid": "f2fb4ebc-698b-4e4f-81b1-6f918e58f23b", "name": "load_p1rlv12528", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9660b80-0fce-4be4-b541-743d5811133c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "afe2c2f2-60ae-474a-84c9-2fb36790d4c8"}}}}, {"uuid": "d799aa9a-afa6-40bc-be59-538d75cef5f6", "name": "e4ebfcf1-30b4-48e9-846b-9c02955861b4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5605855582192873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.02826560468920274, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b12c6d01-4460-4311-a904-c5d13143e75b", "name": "e4ebfcf1-30b4-48e9-846b-9c02955861b4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5605855582192873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.02826560468920274, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "37ef4d0b-b249-4220-a095-69f148aae9ad", "name": "e4ebfcf1-30b4-48e9-846b-9c02955861b4_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5605855582192873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.02826560468920274, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e482f27d-250f-4b0d-8721-098972b804e9", "name": "ca91ac77-bba4-4c41-bf16-c13e29e3f08d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d799aa9a-afa6-40bc-be59-538d75cef5f6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b12c6d01-4460-4311-a904-c5d13143e75b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "37ef4d0b-b249-4220-a095-69f148aae9ad"}}}]}, {"uuid": "c339ffc7-6711-43e4-a6ff-fd769736859f", "name": "load_p1rlv12534", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8796d817-aad6-4d22-b3d4-baf8a686c9df"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e482f27d-250f-4b0d-8721-098972b804e9"}}}}, {"uuid": "a89241f1-f525-4741-95f7-15ebe25f2bf7", "name": "ef38231c-6604-44b3-8ec3-f055074b9f60_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.424752506471074, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.0314252036301887, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "908dbfa2-35f6-4640-9846-29f2d49780b9", "name": "ef38231c-6604-44b3-8ec3-f055074b9f60_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.424752506471074, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.0314252036301887, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "777d5c0c-a10b-4048-97cf-3f3b8987e260", "name": "ef38231c-6604-44b3-8ec3-f055074b9f60_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.424752506471074, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.0314252036301887, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "980ad2f3-5855-4bdc-a897-8daa2e64c474", "name": "136af5b7-a726-451f-900a-e124c28ab761", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a89241f1-f525-4741-95f7-15ebe25f2bf7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "908dbfa2-35f6-4640-9846-29f2d49780b9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "777d5c0c-a10b-4048-97cf-3f3b8987e260"}}}]}, {"uuid": "a74387f0-d972-424b-a0e5-b02d4661ba19", "name": "load_p1rlv12536", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e89452f3-ce44-46d3-a259-f66044e01c2c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "980ad2f3-5855-4bdc-a897-8daa2e64c474"}}}}, {"uuid": "9fa1b332-67ae-4b1c-b3e6-f7a01d4f4309", "name": "e72d8412-519c-4c9b-91b4-d30cabeed95e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0622945809345516, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23624651294541713, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "29f0f8e2-d893-4275-8fee-fc83bc3daa0f", "name": "e72d8412-519c-4c9b-91b4-d30cabeed95e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0622945809345516, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23624651294541713, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c5aa709c-3d6e-4efe-be9c-b404f5629251", "name": "e72d8412-519c-4c9b-91b4-d30cabeed95e_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0622945809345516, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23624651294541713, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5629edce-626f-4f5b-b520-c93cfdc3cc70", "name": "3e0e46c7-cb9f-493c-aa0d-20896a8d1c74", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9fa1b332-67ae-4b1c-b3e6-f7a01d4f4309"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "29f0f8e2-d893-4275-8fee-fc83bc3daa0f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c5aa709c-3d6e-4efe-be9c-b404f5629251"}}}]}, {"uuid": "930c0be3-c6a4-412b-beaf-86f6ec4e901e", "name": "load_p1rlv12985", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df3aae83-f4b0-4db2-9301-dff1664ac23e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5629edce-626f-4f5b-b520-c93cfdc3cc70"}}}}, {"uuid": "ddcd9421-d4d4-4ef3-9f27-f7b5eb64edb3", "name": "24b8b12b-5d1b-46af-a09c-026c4839e859_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.23597191427304684, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09897102743265196, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "379f3f51-cca1-443a-a710-48a9a2856435", "name": "24b8b12b-5d1b-46af-a09c-026c4839e859_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.23597191427304684, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09897102743265196, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ca194c22-8ad4-4093-9b0a-df28ce7dc6d2", "name": "24b8b12b-5d1b-46af-a09c-026c4839e859_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.23597191427304684, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09897102743265196, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8cbaefc5-2d8b-49c8-9e44-885cf1424ae4", "name": "d9bbcea0-08b6-43e9-a41d-40b6878a1638", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ddcd9421-d4d4-4ef3-9f27-f7b5eb64edb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "379f3f51-cca1-443a-a710-48a9a2856435"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ca194c22-8ad4-4093-9b0a-df28ce7dc6d2"}}}]}, {"uuid": "d5cde358-4af8-4e17-9e0a-74099ddb837c", "name": "load_p1rlv16411", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ed6276c-a57b-40be-a1f1-34aaaba0ac28"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8cbaefc5-2d8b-49c8-9e44-885cf1424ae4"}}}}, {"uuid": "75af38b7-bb56-4c47-8f76-f921a8286af9", "name": "77502651-0c93-4d82-9ec9-c1e25cf5e25a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7828407995320632, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7683556122374539, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "547c1fb1-1e21-43de-9124-e75a72e23d31", "name": "77502651-0c93-4d82-9ec9-c1e25cf5e25a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7828407995320632, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7683556122374539, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6a9f4749-ed1a-46fc-8dfa-46c60b940f65", "name": "77502651-0c93-4d82-9ec9-c1e25cf5e25a_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7828407995320632, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7683556122374539, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "90cea8c6-e1fc-4a53-9a62-fbb951d13dc3", "name": "c35e4979-a43e-4803-a90a-5d57dbc220f7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "75af38b7-bb56-4c47-8f76-f921a8286af9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "547c1fb1-1e21-43de-9124-e75a72e23d31"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6a9f4749-ed1a-46fc-8dfa-46c60b940f65"}}}]}, {"uuid": "92d8cb69-f945-46f1-8d83-82c2569dbeb0", "name": "load_p1rlv18169", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c1eac45-623a-4f0a-874d-a4b56a8e2ea7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "90cea8c6-e1fc-4a53-9a62-fbb951d13dc3"}}}}, {"uuid": "75109933-e360-431a-ae56-6a8713fb4e4f", "name": "0c352d6e-62c5-4ca5-aa5f-694c59a9bde2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7765583938143562, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2953468263898592, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "52932e4b-3f68-4d39-9cdf-6831b48e90a2", "name": "0c352d6e-62c5-4ca5-aa5f-694c59a9bde2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7765583938143562, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2953468263898592, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ce695ebd-ff35-4c4e-8193-4b63fcbae6ad", "name": "0c352d6e-62c5-4ca5-aa5f-694c59a9bde2_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7765583938143562, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2953468263898592, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fa9731e1-8866-4fab-8d71-5c264f3aa4a3", "name": "ceabf2fd-a4fe-49a3-b040-998bc449584e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "75109933-e360-431a-ae56-6a8713fb4e4f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "52932e4b-3f68-4d39-9cdf-6831b48e90a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ce695ebd-ff35-4c4e-8193-4b63fcbae6ad"}}}]}, {"uuid": "7a8af673-1f29-42b4-bdc1-b854078775d7", "name": "load_p1rlv18194", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "949f4cce-f321-4bf0-830b-489edc9964c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fa9731e1-8866-4fab-8d71-5c264f3aa4a3"}}}}, {"uuid": "9387af20-49dd-475f-8324-8380a627105a", "name": "f3505cd8-102f-4866-a8e6-83220722e696_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3791309816618758, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4243669985282459, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "68b9e4ad-9706-461f-a964-bdf6fbec6b39", "name": "f3505cd8-102f-4866-a8e6-83220722e696_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3791309816618758, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4243669985282459, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5767b6a3-e20f-4fb6-b4e9-f280bf9623f1", "name": "f3505cd8-102f-4866-a8e6-83220722e696_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3791309816618758, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4243669985282459, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c78d81df-08be-4abd-8543-ba1e3bc71ced", "name": "540ed8e3-c387-4cc6-a726-b7aa52ff1f02", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9387af20-49dd-475f-8324-8380a627105a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "68b9e4ad-9706-461f-a964-bdf6fbec6b39"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5767b6a3-e20f-4fb6-b4e9-f280bf9623f1"}}}]}, {"uuid": "92845255-cba9-4f50-9388-b5806893844f", "name": "load_p1rlv18201", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ead37cb8-af1e-4a46-9466-6ff298b7f8b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c78d81df-08be-4abd-8543-ba1e3bc71ced"}}}}, {"uuid": "66e107e0-5a8d-442d-af88-d909e6806c1d", "name": "cfed4f37-a7eb-470e-9e6e-7429c56af142_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.969330641054165, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5731466084062546, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "788ad97c-109f-4389-8ab7-e5d1aa18711d", "name": "cfed4f37-a7eb-470e-9e6e-7429c56af142_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.969330641054165, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5731466084062546, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1a1efbec-cf76-4c1f-b9d1-8e1f4f40f85f", "name": "cfed4f37-a7eb-470e-9e6e-7429c56af142_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.969330641054165, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5731466084062546, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eb130b96-b1a6-4ad9-92bb-f7c950649d87", "name": "bb4f4ca4-46cc-4d38-974c-bdc47816551a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "66e107e0-5a8d-442d-af88-d909e6806c1d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "788ad97c-109f-4389-8ab7-e5d1aa18711d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1a1efbec-cf76-4c1f-b9d1-8e1f4f40f85f"}}}]}, {"uuid": "1d20a067-0c6f-4dd1-96ae-00fbe68df8be", "name": "load_p1rlv20414", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0a92e79-0ca2-4a10-9050-9e8d7442b019"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eb130b96-b1a6-4ad9-92bb-f7c950649d87"}}}}, {"uuid": "c3167d2e-7abd-4ec9-b7db-189aa1ce6350", "name": "d7a5cbb2-952d-451b-a9c5-797b0d94e7f3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.231046440619022, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3410918425021952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82f1e837-f7ff-45a7-99cd-9947a49f530b", "name": "d7a5cbb2-952d-451b-a9c5-797b0d94e7f3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.231046440619022, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3410918425021952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b62f9ca8-ad3c-458e-8c6c-329a36d278d6", "name": "d7a5cbb2-952d-451b-a9c5-797b0d94e7f3_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.231046440619022, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3410918425021952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "80fd6578-bbee-4566-9069-5278cad9984b", "name": "d76b08ad-4f91-4cda-9fc7-106a67597cb1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c3167d2e-7abd-4ec9-b7db-189aa1ce6350"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "82f1e837-f7ff-45a7-99cd-9947a49f530b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b62f9ca8-ad3c-458e-8c6c-329a36d278d6"}}}]}, {"uuid": "0f1e4fed-f27c-407f-bb1b-0a713223b7c4", "name": "load_p1rlv20501", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cebe1b53-cca6-4bd4-a9f0-616ffb9750b3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "80fd6578-bbee-4566-9069-5278cad9984b"}}}}, {"uuid": "d452202d-9209-43e3-9f1b-676ca771bf58", "name": "b438d550-9204-4deb-b624-2af3f3f95abf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.718035027374153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.747804250682338, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e61ddcce-02b6-49db-8ac0-51d03bffec33", "name": "153d6d88-fe56-4daa-8fe9-2cc8ef339106", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d452202d-9209-43e3-9f1b-676ca771bf58"}}}]}, {"uuid": "742d6d8b-18ae-42cc-9249-c8f8e8f4f378", "name": "load_p1rlv183_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3df778b4-e60b-4e17-b24b-67742d090f42"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e61ddcce-02b6-49db-8ac0-51d03bffec33"}}}}, {"uuid": "50a6d660-3a31-481e-a6c6-f9690dbb7ca1", "name": "ea228642-f5c5-468e-a9dd-409a56d9f874_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.718035027374153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.747804250682338, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8bda7891-b82b-426f-b18c-5eb0fb925fd2", "name": "10d93e0c-b904-4504-aacd-b5f5838c6695", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "50a6d660-3a31-481e-a6c6-f9690dbb7ca1"}}}]}, {"uuid": "48054bdd-5552-4b5b-be40-7d539c24e9dd", "name": "load_p1rlv183_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3df778b4-e60b-4e17-b24b-67742d090f42"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8bda7891-b82b-426f-b18c-5eb0fb925fd2"}}}}, {"uuid": "c2546b6f-fccd-47a4-b41a-52ade98419c7", "name": "a75381a0-7cd8-4979-84c6-33a9b055fcfa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.127855103696037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.9003395103499228, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4e801885-fc8b-44e6-8cff-8ca4ce49e685", "name": "4d068117-da86-4eb2-98b5-8795e125680a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c2546b6f-fccd-47a4-b41a-52ade98419c7"}}}]}, {"uuid": "c8e3ab78-fc66-4999-a4a3-9f6f6034ea51", "name": "load_p1rlv184_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42ca8327-5dcc-415a-820c-ef6ec038b3d8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4e801885-fc8b-44e6-8cff-8ca4ce49e685"}}}}, {"uuid": "66861fae-18d4-4b12-89f9-a42a505c43fe", "name": "f1233123-1f28-4f98-a380-9a86a8c78985_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.127855103696037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.9003395103499228, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2c03d88e-748c-47a3-b381-2286aeb0abd2", "name": "6f60df77-8937-41d3-b043-9b28c08007c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "66861fae-18d4-4b12-89f9-a42a505c43fe"}}}]}, {"uuid": "db648879-6a88-469a-b3ad-bab23c777335", "name": "load_p1rlv184_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42ca8327-5dcc-415a-820c-ef6ec038b3d8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2c03d88e-748c-47a3-b381-2286aeb0abd2"}}}}, {"uuid": "344cdbb3-a80c-404d-9261-eab3f95c614f", "name": "9c4438d4-ff81-4106-afbc-33f8775b30ce_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.1997144025033135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.11221312599546865, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "83102fd9-ad7e-4a54-8f3b-de4b3131ce41", "name": "6e16813c-5d8c-4a79-810c-0c69e27021cc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "344cdbb3-a80c-404d-9261-eab3f95c614f"}}}]}, {"uuid": "958e832c-6fa1-49f6-b718-480453e9d335", "name": "load_p1rlv190_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33b6400e-c84e-43cf-b254-99f946e5a308"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "83102fd9-ad7e-4a54-8f3b-de4b3131ce41"}}}}, {"uuid": "51739107-d681-47db-a519-530a5d81e380", "name": "81398e9c-c69f-44f1-ae1f-52bf38236f43_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.1997144025033135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.11221312599546865, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4ce391b4-aef8-4ab8-918f-0b278f46c29c", "name": "e6cd5f06-51c1-4e78-a54c-b363b90f918e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "51739107-d681-47db-a519-530a5d81e380"}}}]}, {"uuid": "f5fc5e6d-4a64-4320-b5f3-efa23416a9d2", "name": "load_p1rlv190_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33b6400e-c84e-43cf-b254-99f946e5a308"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4ce391b4-aef8-4ab8-918f-0b278f46c29c"}}}}, {"uuid": "f9119206-6129-4831-af07-d5ed4b642c85", "name": "e8661d29-1ea4-4741-ad74-bd78340ddd97_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.549201052937441, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.4274432384427707, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "71a46f8f-842d-4937-a801-10ae42b24e5f", "name": "6a3d3aef-865d-46e9-a960-161498a719fe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f9119206-6129-4831-af07-d5ed4b642c85"}}}]}, {"uuid": "81c21836-45b0-4154-82ae-266770c938c2", "name": "load_p1rlv193_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84223c1b-69e4-4ebc-8274-8706bb412780"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "71a46f8f-842d-4937-a801-10ae42b24e5f"}}}}, {"uuid": "58f983e5-4e84-49bc-91b5-e3a89fdfa15b", "name": "c5f60dda-40d2-4501-b095-c3a416842481_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.549201052937441, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.4274432384427707, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "64473a35-4b5a-4b3b-9df1-622a7c2e80f0", "name": "6eb521f5-3493-4631-9d8e-09e4fdf20bb4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58f983e5-4e84-49bc-91b5-e3a89fdfa15b"}}}]}, {"uuid": "30dac874-159f-460d-82b9-04974e73e308", "name": "load_p1rlv193_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84223c1b-69e4-4ebc-8274-8706bb412780"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "64473a35-4b5a-4b3b-9df1-622a7c2e80f0"}}}}, {"uuid": "a628d381-76e4-40cf-bc24-857e04147606", "name": "22ff9d9d-ac24-4905-9832-998eae8c6b4e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.052819039029729, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6406126314043256, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "45fd4d14-39df-4fa4-b612-a444a80083df", "name": "e5b3eba3-131f-4d1b-ac25-750cf0a4f239", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a628d381-76e4-40cf-bc24-857e04147606"}}}]}, {"uuid": "5557aa36-6bc2-494a-8072-27bd794500fb", "name": "load_p1rlv202_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "de2366e4-30da-429a-82b9-c0ef27eeab47"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "45fd4d14-39df-4fa4-b612-a444a80083df"}}}}, {"uuid": "23222d19-9d59-45d2-a78d-58fc93fd5c6a", "name": "73133d72-263e-4d0d-987b-43979afa5ec3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.052819039029729, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6406126314043256, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "18272da0-9eb7-4022-ba19-f26531774504", "name": "51166873-b93f-4926-9e62-57215002bd49", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "23222d19-9d59-45d2-a78d-58fc93fd5c6a"}}}]}, {"uuid": "ce162529-8696-48ac-a532-4fcc622d5dcd", "name": "load_p1rlv202_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "de2366e4-30da-429a-82b9-c0ef27eeab47"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "18272da0-9eb7-4022-ba19-f26531774504"}}}}, {"uuid": "d11e80ed-46b6-44dd-afc2-5a36e25a5ea6", "name": "7b83fc9d-61ee-4397-8667-a8588c3bc7c9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 10.312489622510887, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5278845211341558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "86764a50-118f-4ae0-904c-3eb7d9149897", "name": "a56124cc-b228-47df-b16e-25063ca6be04", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d11e80ed-46b6-44dd-afc2-5a36e25a5ea6"}}}]}, {"uuid": "a54e9ee0-d987-4d48-8ca7-d8104322c7c8", "name": "load_p1rlv204_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d663fcdc-6c67-4bc9-99ed-12439f75804f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "86764a50-118f-4ae0-904c-3eb7d9149897"}}}}, {"uuid": "57c0a953-1df6-4ccd-bc63-5a6de34ae501", "name": "48bffe9b-9342-4db0-9ae8-708b0d958dc6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 10.312489622510887, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5278845211341558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "99a56edd-9cc3-431a-8528-a4b629d07122", "name": "c8f70a44-fc85-4b43-84d4-1d98126976c7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "57c0a953-1df6-4ccd-bc63-5a6de34ae501"}}}]}, {"uuid": "f5df41fa-acf8-47b6-87fa-8f483834918a", "name": "load_p1rlv204_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d663fcdc-6c67-4bc9-99ed-12439f75804f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "99a56edd-9cc3-431a-8528-a4b629d07122"}}}}, {"uuid": "63d5acfc-0745-4111-8177-dd66ae09918b", "name": "8d4d1bae-d8e2-4947-998e-f570b1a6b343_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9264329962341185, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3633013910451994, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "54707afb-12f1-4423-950c-81e7e8b8cb3d", "name": "461691a0-b77c-4154-a045-49dcb5767ddc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "63d5acfc-0745-4111-8177-dd66ae09918b"}}}]}, {"uuid": "0db73d3b-1367-4883-92fb-b35b5fe61489", "name": "load_p1rlv206_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90aa0d14-285a-4468-bbde-8d76f65b1780"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "54707afb-12f1-4423-950c-81e7e8b8cb3d"}}}}, {"uuid": "cafb2fa3-b0e4-42e8-b518-09654adfe279", "name": "0cfa0843-e053-415d-9e17-f093387d41dc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9264329962341185, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3633013910451994, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9f52038c-27b1-4970-ae57-228257c9bf35", "name": "76c3855d-0b8d-4cb8-9027-5eb6091bd9a4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cafb2fa3-b0e4-42e8-b518-09654adfe279"}}}]}, {"uuid": "ab252666-2ea9-4e1c-aa7a-e49d13cad5fe", "name": "load_p1rlv206_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90aa0d14-285a-4468-bbde-8d76f65b1780"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9f52038c-27b1-4970-ae57-228257c9bf35"}}}}, {"uuid": "0e86c524-7124-441d-8f10-66f45ed36a68", "name": "8ba30a99-87f5-446e-ace9-b55d7af9360b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.495920496244223, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.518490967551786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "239be45a-d09b-44fb-9a2b-b33b6edd3876", "name": "6e0cfa39-9b52-47ac-87fe-e50f8b5afb6c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0e86c524-7124-441d-8f10-66f45ed36a68"}}}]}, {"uuid": "dadd83f6-5ccf-4bac-ab6f-cae797485027", "name": "load_p1rlv207_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6627102c-4524-4e69-bb4d-5b93226df412"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "239be45a-d09b-44fb-9a2b-b33b6edd3876"}}}}, {"uuid": "9ab22791-181c-4d6f-9cc0-3b61593d3e1d", "name": "ffba4d1d-3ac4-4596-8520-a1ba07ae099e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.495920496244223, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.518490967551786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b22fe0e0-baee-4fe0-b605-ddd37c2ffc6a", "name": "4c32cfe6-8a80-42a6-8417-c3d18f08fcac", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9ab22791-181c-4d6f-9cc0-3b61593d3e1d"}}}]}, {"uuid": "4775bbae-5798-4601-a801-b706bf2c4ee6", "name": "load_p1rlv207_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6627102c-4524-4e69-bb4d-5b93226df412"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b22fe0e0-baee-4fe0-b605-ddd37c2ffc6a"}}}}, {"uuid": "cbc3c1e0-4de2-487d-9596-35203ed448d3", "name": "7f5018a1-d799-4607-bdb7-1808ad52c298_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.1298927880171155, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3569806362972607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eb992e66-c752-4374-a1e0-6b6209cd65af", "name": "f42b3cc4-474a-4489-9d4b-4eec13d43e4b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cbc3c1e0-4de2-487d-9596-35203ed448d3"}}}]}, {"uuid": "925eea4e-1656-49bf-8ff1-d56eb17907ab", "name": "load_p1rlv212_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a982feac-5730-4fe0-a1b8-25c06b36e3b0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eb992e66-c752-4374-a1e0-6b6209cd65af"}}}}, {"uuid": "4154954c-7a18-456b-8622-52f9c2893e7c", "name": "69490a8c-b272-46ef-a77f-31b698c067c7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.1298927880171155, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3569806362972607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f0618bd8-742f-4511-a715-4b51b8f630cb", "name": "90e2596a-5f5a-4214-bd68-9ceaea0de7cf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4154954c-7a18-456b-8622-52f9c2893e7c"}}}]}, {"uuid": "82788e05-b8cc-4374-b70a-1b283d49b619", "name": "load_p1rlv212_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a982feac-5730-4fe0-a1b8-25c06b36e3b0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f0618bd8-742f-4511-a715-4b51b8f630cb"}}}}, {"uuid": "d0f61b3d-9dd8-45cc-b426-9ef0aaac7c1b", "name": "d7e028a1-2a14-4d50-8030-c93bc7628a90_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.583696505537418, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4678810835686954, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "25f54090-d0d6-42d4-b9aa-0b3231c4361b", "name": "082a6d0f-4854-44e3-9719-141d16201519", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d0f61b3d-9dd8-45cc-b426-9ef0aaac7c1b"}}}]}, {"uuid": "0720a126-2cc3-4dc6-af38-58177f078903", "name": "load_p1rlv12687_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "163c3824-6847-4b94-9e81-08f15f4667a1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "25f54090-d0d6-42d4-b9aa-0b3231c4361b"}}}}, {"uuid": "4a209186-c2ca-47e3-91c2-43756ee9d9d1", "name": "eb25abe8-65f1-4081-a59a-54ed4be1f40b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.583696505537418, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4678810835686954, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5df58dd4-8b5e-4767-8d0b-014a76f208cc", "name": "0c67fd09-9f70-4278-b5c3-87ba4c32d4a4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4a209186-c2ca-47e3-91c2-43756ee9d9d1"}}}]}, {"uuid": "587b7bd5-45c9-4d29-a103-1654b7609e31", "name": "load_p1rlv12687_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "163c3824-6847-4b94-9e81-08f15f4667a1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5df58dd4-8b5e-4767-8d0b-014a76f208cc"}}}}, {"uuid": "7c9572f6-3d24-49ce-8e4b-bd40d675d2ff", "name": "24658cf7-3b72-4072-aa99-2aa43e79f68e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.073647835052278, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9870900939844905, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "78dc3bd2-faee-4bfa-a8ad-e73cef6d4bb8", "name": "10dbcd6c-c7d5-4021-8409-dbecd8397b67", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7c9572f6-3d24-49ce-8e4b-bd40d675d2ff"}}}]}, {"uuid": "acd5ef5c-b674-4b1a-bb31-a05b03cac46d", "name": "load_p1rlv12713_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff16aad0-98c1-4563-a844-e0ce909c1a79"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "78dc3bd2-faee-4bfa-a8ad-e73cef6d4bb8"}}}}, {"uuid": "6c8c64d5-8232-48f3-b779-e284a0d79625", "name": "2e710491-6935-4c22-a3fb-03a66154e627_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.073647835052278, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9870900939844905, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f197177b-277e-4088-b0ad-e2d741d93d9f", "name": "b7ff3a42-4e19-4355-b425-f3c12537a70e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c8c64d5-8232-48f3-b779-e284a0d79625"}}}]}, {"uuid": "3f3a20a9-a720-4b31-a158-a8d5a99ac7c5", "name": "load_p1rlv12713_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff16aad0-98c1-4563-a844-e0ce909c1a79"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f197177b-277e-4088-b0ad-e2d741d93d9f"}}}}, {"uuid": "f165255b-c573-44e3-84cd-49783a88ab2e", "name": "1dbad6e5-8c1a-4011-bea1-bff55d509e1c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.717517070184915, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6715744239051029, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "420a0bce-f51c-4b62-8e6b-9a387e86a735", "name": "b4b542a3-23bc-49fe-8b97-9061f3eb79d0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f165255b-c573-44e3-84cd-49783a88ab2e"}}}]}, {"uuid": "18ffffa2-9edd-4b1e-9e65-5b6c6bae3648", "name": "load_p1rlv17006_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b53edd15-5a3e-4b7a-97c4-046582bb4801"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "420a0bce-f51c-4b62-8e6b-9a387e86a735"}}}}, {"uuid": "3a246336-b14b-440f-bc6a-b422db5dbaf9", "name": "eb6052a5-cda9-4e21-bc34-c012cb2a45c9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.717517070184915, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6715744239051029, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "daf286f3-ba08-4a4a-a63b-e2444b88c23b", "name": "34263f6f-fb33-4385-b0da-d5e94b1c7962", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3a246336-b14b-440f-bc6a-b422db5dbaf9"}}}]}, {"uuid": "60052a5b-71bb-4bc8-8e08-ce9093d39625", "name": "load_p1rlv17006_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b53edd15-5a3e-4b7a-97c4-046582bb4801"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "daf286f3-ba08-4a4a-a63b-e2444b88c23b"}}}}, {"uuid": "7b15de94-09be-4c5d-bcad-51da9006d9b8", "name": "4e35b209-fd6d-4c40-8295-c4c03decf7ed_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.232057012168481, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2513317849586886, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a0b81f47-b2c7-481f-b0d6-0a682a1f9e12", "name": "1cd07c6b-4cb5-4c8c-894d-049edc6327bf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b15de94-09be-4c5d-bcad-51da9006d9b8"}}}]}, {"uuid": "062e62cb-fef0-435f-8624-d1ce4dce2226", "name": "load_p1rlv17103_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ff9eb4c-2523-48e0-8490-619d26b9cca4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a0b81f47-b2c7-481f-b0d6-0a682a1f9e12"}}}}, {"uuid": "cf5c4bd5-036b-40d7-b817-cc747db47804", "name": "3052e4cd-e42c-46e4-a14f-22b6800c7106_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.232057012168481, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2513317849586886, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fa3a0152-406c-41d9-823e-8e9d0c488cb3", "name": "7de8fa38-01f0-48ce-bd95-b70f4741c401", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cf5c4bd5-036b-40d7-b817-cc747db47804"}}}]}, {"uuid": "97bbad00-72ba-4f7f-9c82-ae75e91ccf17", "name": "load_p1rlv17103_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ff9eb4c-2523-48e0-8490-619d26b9cca4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fa3a0152-406c-41d9-823e-8e9d0c488cb3"}}}}, {"uuid": "41fbaba5-530d-45c4-8ac2-003cdc444c4b", "name": "2e037faf-fd59-47a0-b8d8-baff8428d902_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2219087879829873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3595087789107823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c00fb412-46d2-4e3b-b892-4c29ed9a96dc", "name": "34327e4c-a3bf-4a34-bb48-d1805c4c2b46", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "41fbaba5-530d-45c4-8ac2-003cdc444c4b"}}}]}, {"uuid": "94e1ce9a-0ea6-41c7-8acd-3c47597808c8", "name": "load_p1rlv17155_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3c6c52e-cf93-467a-a303-94b96b33a3da"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c00fb412-46d2-4e3b-b892-4c29ed9a96dc"}}}}, {"uuid": "bcd3781d-68d3-49c8-98f2-5d2dfd72d02c", "name": "c24d5d86-507c-4da1-a740-cbfa6e9b70d8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2219087879829873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3595087789107823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "367d3fb3-38e1-46a9-afe8-6002ec634b34", "name": "096662e5-09d2-4d3f-83b8-7e5c0313d32b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bcd3781d-68d3-49c8-98f2-5d2dfd72d02c"}}}]}, {"uuid": "ea2204e5-c733-4c5d-9f57-f1ae7993930e", "name": "load_p1rlv17155_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3c6c52e-cf93-467a-a303-94b96b33a3da"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "367d3fb3-38e1-46a9-afe8-6002ec634b34"}}}}, {"uuid": "5ca29a6b-8871-4316-9614-9cdc26b525c3", "name": "b34ee401-7b3b-4bd1-aecd-b49dc4a423cd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.942829069048031, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.025560880160820944, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "28234f8d-0f72-4591-a0e5-92555cccad67", "name": "26114456-b716-42bd-b5cd-0cb881ca3c1e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5ca29a6b-8871-4316-9614-9cdc26b525c3"}}}]}, {"uuid": "3788a4d6-fb67-408b-a39a-382a54c99337", "name": "load_p1rlv17164_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "041caa30-2985-44ca-8013-e11a9bda7dff"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "28234f8d-0f72-4591-a0e5-92555cccad67"}}}}, {"uuid": "d1180f7a-4072-4682-9e72-f7710c39e782", "name": "1c5d76ca-3c9e-4297-a20f-bd64dbf176a2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.942829069048031, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.025560880160820944, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "62763e78-f998-4c71-9591-66a454e2912d", "name": "3d73307b-f167-4794-a374-6943ca16307f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d1180f7a-4072-4682-9e72-f7710c39e782"}}}]}, {"uuid": "607dd42d-074f-451c-abe2-2be23e589cec", "name": "load_p1rlv17164_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "041caa30-2985-44ca-8013-e11a9bda7dff"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "62763e78-f998-4c71-9591-66a454e2912d"}}}}, {"uuid": "21a8d94a-5f88-43e9-86ad-5de85cc4c1bc", "name": "d6f25302-9bf5-4b6b-8109-772358bb7981_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.232057012168481, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2513317849586886, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d8ce9ad7-c027-48cb-8677-3e76b8508613", "name": "fc57ffc1-a1a5-4772-ab6c-285ce5f0b9be", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "21a8d94a-5f88-43e9-86ad-5de85cc4c1bc"}}}]}, {"uuid": "921af739-3a49-488e-b908-a755178667b5", "name": "load_p1rlv17167_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b4e44ab-e644-4e48-b1b2-82dc15d38d17"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d8ce9ad7-c027-48cb-8677-3e76b8508613"}}}}, {"uuid": "c95623eb-7e70-4230-89ec-95912a3b104e", "name": "870b8ada-fd08-4206-9fc5-01346c9ff362_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.232057012168481, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2513317849586886, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1ce786d2-8a25-4b49-a086-d96fa76a8d08", "name": "d75ae0f2-7d95-4690-b229-56fce3ab59ee", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c95623eb-7e70-4230-89ec-95912a3b104e"}}}]}, {"uuid": "b4f5139d-e8a9-4b09-81cc-226782639deb", "name": "load_p1rlv17167_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b4e44ab-e644-4e48-b1b2-82dc15d38d17"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1ce786d2-8a25-4b49-a086-d96fa76a8d08"}}}}, {"uuid": "7446423d-82b3-4d10-bcf9-723674add925", "name": "d3372449-16d8-484a-a833-f29fb227400d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9560799536695528, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.499516661128582, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6819cfd1-4ede-49bb-80b3-81faba8c4337", "name": "26394e59-96de-4fcd-bdf3-b8c99b381804", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7446423d-82b3-4d10-bcf9-723674add925"}}}]}, {"uuid": "a26b6799-9da9-46b0-974d-186fa2a110ef", "name": "load_p1rlv17199_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5768eaca-abe3-4347-af78-02b50ec6f2a9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6819cfd1-4ede-49bb-80b3-81faba8c4337"}}}}, {"uuid": "aec4bb52-4e0e-4666-b311-aff796a6e741", "name": "9fd2156c-d0a8-4aeb-a216-5711fc5b8345_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9560799536695528, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.499516661128582, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6bbfcac3-e8d6-49b5-b0ed-56f508d367d2", "name": "0504995a-08d3-4acf-a5ec-f035fb0edd55", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aec4bb52-4e0e-4666-b311-aff796a6e741"}}}]}, {"uuid": "f16ea12a-d96f-4c89-aae1-a9e2f73b498e", "name": "load_p1rlv17199_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5768eaca-abe3-4347-af78-02b50ec6f2a9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6bbfcac3-e8d6-49b5-b0ed-56f508d367d2"}}}}, {"uuid": "9501db4f-4d34-46ab-b337-a9b58a0ecc04", "name": "c7920de9-9700-44da-88a2-baee1b71a3fa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4651344294517608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7736313908316925, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3e397dca-c5aa-41b9-a651-a5594d57ce82", "name": "b3217784-6b6f-4cbb-ae04-0586946430b3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9501db4f-4d34-46ab-b337-a9b58a0ecc04"}}}]}, {"uuid": "486b1fa9-c97d-4d8f-8dd5-a12f4ed1f6a4", "name": "load_p1rlv17376_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c9970ae-e914-407d-8222-12c08638a854"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3e397dca-c5aa-41b9-a651-a5594d57ce82"}}}}, {"uuid": "d1c9d7de-ec26-4339-b074-a8feed5b6bd3", "name": "b9ef11a0-e24d-411d-9d2d-b1d7f910cbf7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4651344294517608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7736313908316925, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3f324903-fa8c-4c76-a937-15d2f343d5e4", "name": "365eec18-9d98-4ef6-a549-3c01f3c032ad", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d1c9d7de-ec26-4339-b074-a8feed5b6bd3"}}}]}, {"uuid": "e074293a-eec0-4036-a797-8b60e105c83f", "name": "load_p1rlv17376_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c9970ae-e914-407d-8222-12c08638a854"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3f324903-fa8c-4c76-a937-15d2f343d5e4"}}}}, {"uuid": "ead23219-08fe-44ab-820a-d0d14103563b", "name": "ba31d245-a5df-4e40-bd84-2537388de1de_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f20bbd88-d644-4460-b91b-f7d7a0dd9c33", "name": "e7afd31e-cc94-4190-bd64-93c2978c75e8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ead23219-08fe-44ab-820a-d0d14103563b"}}}]}, {"uuid": "c7830443-55ae-4071-84cd-61cb658dfa1d", "name": "load_p1rlv17402_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc7fa312-1baf-4f23-925f-a281071183a6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f20bbd88-d644-4460-b91b-f7d7a0dd9c33"}}}}, {"uuid": "c032abac-cd1f-4a1e-bbd5-d4802c4799f8", "name": "7aee58e6-4854-4da3-b1b6-cd96d079e46f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d9b0b461-3686-46ed-a372-44fe942df55a", "name": "08b8a5f8-54ac-4bef-9a93-f060a37836e7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c032abac-cd1f-4a1e-bbd5-d4802c4799f8"}}}]}, {"uuid": "c4c2d28d-64de-4aef-9b56-71b581140ea8", "name": "load_p1rlv17402_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc7fa312-1baf-4f23-925f-a281071183a6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d9b0b461-3686-46ed-a372-44fe942df55a"}}}}, {"uuid": "c6d70775-0474-4758-9e2b-53a281b01f2b", "name": "951110b2-1b20-46ea-97ea-669c68971c74_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cece30de-5748-49d0-95c9-04aae051c96b", "name": "934dfe2f-a3da-4353-ab7d-ff5cf4bd4aca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c6d70775-0474-4758-9e2b-53a281b01f2b"}}}]}, {"uuid": "4de72967-d0e0-4245-a2c9-90ed95c634db", "name": "load_p1rlv17413_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f147f7e5-33e8-430b-9822-715e772debb3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cece30de-5748-49d0-95c9-04aae051c96b"}}}}, {"uuid": "410be76a-d3e6-4fe5-8234-da21b56ab803", "name": "86f67b91-abe0-4707-b5b7-1fc268250b03_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a1f185f9-ed32-4e4d-8ab5-4cb30f46e1fa", "name": "be5f5a1e-d7c2-4cc0-b2ec-ebb2f4d99001", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "410be76a-d3e6-4fe5-8234-da21b56ab803"}}}]}, {"uuid": "c17dc359-c1e8-4ac0-b8b5-6f4911806a06", "name": "load_p1rlv17413_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f147f7e5-33e8-430b-9822-715e772debb3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a1f185f9-ed32-4e4d-8ab5-4cb30f46e1fa"}}}}, {"uuid": "2b1560aa-044b-4355-a313-8393ed56e206", "name": "7091f011-29cf-4970-a077-57d16406022c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.892763602300674, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6648734705927571, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4bc73f95-dad0-426c-9936-a29efa07e8e8", "name": "54d54f42-88ad-4e97-8ab7-0abf5a820925", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2b1560aa-044b-4355-a313-8393ed56e206"}}}]}, {"uuid": "bdf7f58c-d310-4d81-a73e-f4b0b1a4ce42", "name": "load_p1rlv18362_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a28b095-45f5-43ec-983b-c1de596d4cb5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4bc73f95-dad0-426c-9936-a29efa07e8e8"}}}}, {"uuid": "257a4574-d5ef-4c96-9b9f-d77e051fafe0", "name": "91b731da-63f3-4bc2-b6e9-af3b83093c8d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.892763602300674, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6648734705927571, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d8380065-441a-43ce-be4c-f8346bb2f521", "name": "2874337f-dfcb-4793-be27-1510b75a005f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "257a4574-d5ef-4c96-9b9f-d77e051fafe0"}}}]}, {"uuid": "d490ecf2-bbea-47c7-acb6-20d2732d4e2e", "name": "load_p1rlv18362_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a28b095-45f5-43ec-983b-c1de596d4cb5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d8380065-441a-43ce-be4c-f8346bb2f521"}}}}, {"uuid": "75ddb8f7-60f7-490b-bf33-5873e706c7bf", "name": "87c379cb-60d1-4d1c-a9cd-99664fa99d1c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6733980323267108, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22626974414284334, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "584dc0fb-4cac-4f30-9134-437168f50f38", "name": "b498951a-0c47-4046-ad51-574662d33fe5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "75ddb8f7-60f7-490b-bf33-5873e706c7bf"}}}]}, {"uuid": "16da4765-2a94-42b2-8fa3-ee4d896e71d7", "name": "load_p1rlv18364_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d1c3d0a-9def-4516-8429-386f1d70f506"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "584dc0fb-4cac-4f30-9134-437168f50f38"}}}}, {"uuid": "92e69644-de04-43d7-b2e1-0e3bd74982eb", "name": "266a88e0-df41-41ca-bfb6-60e12a5941f7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6733980323267108, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22626974414284334, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e9864b39-af63-4922-a8d4-02e847767bcc", "name": "a91ad431-0ff6-4239-b74c-a5d9e3850a5c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "92e69644-de04-43d7-b2e1-0e3bd74982eb"}}}]}, {"uuid": "da244663-5b6a-4fd8-a1f5-ac4badf33a37", "name": "load_p1rlv18364_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d1c3d0a-9def-4516-8429-386f1d70f506"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e9864b39-af63-4922-a8d4-02e847767bcc"}}}}, {"uuid": "a9ddfd1d-3312-40ce-bb2e-0ad14e5534c0", "name": "1952fc3c-5bb1-4426-aedd-3b281fbbcce4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5880239691905954, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.38099900657746644, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4b8ad38a-67e8-44ef-85a8-e7448d462d0f", "name": "66287ea0-a48c-4197-8596-01b7383329a5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a9ddfd1d-3312-40ce-bb2e-0ad14e5534c0"}}}]}, {"uuid": "b9c897cb-86a2-49e9-9eb4-373574153ce3", "name": "load_p1rlv18367_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "408c825d-17ac-4aea-9fc7-fff420657fc7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4b8ad38a-67e8-44ef-85a8-e7448d462d0f"}}}}, {"uuid": "743c8186-d479-45e9-b3bc-a35e639913a6", "name": "5dd5f3e7-b82b-4663-aa29-5f66bf7ec617_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5880239691905954, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.38099900657746644, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "accd5657-d180-46cc-b3f6-078c5d6c4023", "name": "ef824912-fe95-47a6-a947-dc3cd4ae0fe6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "743c8186-d479-45e9-b3bc-a35e639913a6"}}}]}, {"uuid": "2bb645d5-61aa-411d-a6ca-d3858ae387f3", "name": "load_p1rlv18367_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "408c825d-17ac-4aea-9fc7-fff420657fc7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "accd5657-d180-46cc-b3f6-078c5d6c4023"}}}}, {"uuid": "7b1b9654-8f6f-41f8-9949-7c667f121221", "name": "ae93fb7d-8b86-4bc8-8c76-23340af3316e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.287089484997603, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1789824543876289, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "40b0ac72-0e92-4d11-8da5-eac2a4d51459", "name": "a32daa16-e1f3-4307-b131-b623a894e02a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b1b9654-8f6f-41f8-9949-7c667f121221"}}}]}, {"uuid": "188c068c-f0d5-42db-b95f-b14c18ac3ead", "name": "load_p1rlv18370_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905e171c-13d7-4f8d-b88a-7501b2327d81"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "40b0ac72-0e92-4d11-8da5-eac2a4d51459"}}}}, {"uuid": "68317224-66ee-48bc-b78a-da4bb713889f", "name": "e2e5bbaa-022b-4234-992f-0c2ac3cf90a1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.287089484997603, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1789824543876289, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "41fea339-814b-42d1-8c26-64a3fa35ebbe", "name": "18efa5ce-5d1b-485f-9ecc-c872b07928f1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "68317224-66ee-48bc-b78a-da4bb713889f"}}}]}, {"uuid": "9ae409db-c6ba-45ca-9a8a-331455db2e0e", "name": "load_p1rlv18370_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905e171c-13d7-4f8d-b88a-7501b2327d81"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "41fea339-814b-42d1-8c26-64a3fa35ebbe"}}}}, {"uuid": "793805f3-a494-4fa1-a522-74e0ac925749", "name": "dfb5f81d-e24b-45c7-8605-ddb09f7d9eb3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2520868864654517, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.447133871274774, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d5aa70af-2ee7-4b7d-b94f-3ea222b385c2", "name": "125e24fe-6596-4d6d-94db-5dbf4bc5e421", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "793805f3-a494-4fa1-a522-74e0ac925749"}}}]}, {"uuid": "0f43e824-7939-4679-98c8-608f518dd550", "name": "load_p1rlv18371_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58792e8c-3ad9-45bb-ac47-01983cca2a2b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d5aa70af-2ee7-4b7d-b94f-3ea222b385c2"}}}}, {"uuid": "69f19827-944b-4a54-a28e-0dfe9c47b0fc", "name": "390f6dbf-4017-4c8e-bceb-b4bfeb8f2003_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2520868864654517, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.447133871274774, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e70868cc-51f0-42a5-819e-83d4b3dbf361", "name": "931fc67d-b740-4547-9b8b-b33ffdbde5cb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "69f19827-944b-4a54-a28e-0dfe9c47b0fc"}}}]}, {"uuid": "67f1c6b3-83b2-48f1-9099-9b28b64418ad", "name": "load_p1rlv18371_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58792e8c-3ad9-45bb-ac47-01983cca2a2b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e70868cc-51f0-42a5-819e-83d4b3dbf361"}}}}, {"uuid": "b686fa6e-2461-4808-9066-25867f45ba9d", "name": "420e1a0a-ffcb-4581-8b92-d552392c4fee_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8791002615066037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24190904367644575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b9fcde9a-cbbd-4ec9-92f8-ff41efd0cf35", "name": "7c92f79e-4b96-4736-b8a9-6742d7ac1ddb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b686fa6e-2461-4808-9066-25867f45ba9d"}}}]}, {"uuid": "b7724836-8957-44b6-a1ee-1e13527201ca", "name": "load_p1rlv22745_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a86348e4-7573-4903-b223-90155579923e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b9fcde9a-cbbd-4ec9-92f8-ff41efd0cf35"}}}}, {"uuid": "53db9d3b-3c21-40c5-80a9-ef617736c9a8", "name": "5ff251b3-da3d-4586-825b-ac39058ba513_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8791002615066037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24190904367644575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5a8333e2-17ee-4e51-a880-051e78240562", "name": "4aaed0fb-53e6-4c5b-9cab-4e1899e05ed4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "53db9d3b-3c21-40c5-80a9-ef617736c9a8"}}}]}, {"uuid": "85381bbb-b76b-4491-8426-3f1f546557da", "name": "load_p1rlv22745_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a86348e4-7573-4903-b223-90155579923e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5a8333e2-17ee-4e51-a880-051e78240562"}}}}, {"uuid": "2616a540-3729-4d1c-9e19-3e6dd7591c99", "name": "0d546f4b-fb69-4955-892c-71bff61644ad_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4163439957648214, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5697938312046736, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "573e0cb7-9d98-4b90-8399-be6d8152d6aa", "name": "8080e54c-51ef-46b6-b0ec-6207aec4ee3e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2616a540-3729-4d1c-9e19-3e6dd7591c99"}}}]}, {"uuid": "e52b1a47-a419-442d-ad0a-75dd5602f688", "name": "load_p1rlv22758_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db05b7f0-d2a8-4876-876e-ef0e9b469580"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "573e0cb7-9d98-4b90-8399-be6d8152d6aa"}}}}, {"uuid": "6e457b9f-df86-4742-8b47-d0463266fc5c", "name": "f96e1a4f-9a54-4b4c-b072-9ccb0d534841_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4163439957648214, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5697938312046736, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6733e95a-a926-463a-b097-3eadebfffe1b", "name": "f77f6636-5ffb-4446-a8c7-6d920b16449a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6e457b9f-df86-4742-8b47-d0463266fc5c"}}}]}, {"uuid": "462e1f9c-3a5f-4f5b-a281-0d93e7ab513d", "name": "load_p1rlv22758_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db05b7f0-d2a8-4876-876e-ef0e9b469580"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6733e95a-a926-463a-b097-3eadebfffe1b"}}}}, {"uuid": "e4ea7fd7-7dd6-4aa3-b984-f4806c69c9cd", "name": "", "resistance": 0.33831264, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 3, "connection_type": "DELTA", "tap_positions": [1.0, 1.0, 1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 39.838337182448036, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 30000.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "9a9d218f-3818-4abe-9c9f-7fee34acb7cc", "name": "", "resistance": 0.33831264, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 3, "connection_type": "STAR", "tap_positions": [1.03125, 1.03125, 1.03125], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.199769053117783, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 30000.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "0ff22131-b16e-4e2e-808a-862b62584bf5", "name": "5ea8fd3b-2d5b-4c48-84db-0b2934c03576", "pct_no_load_loss": 0.0, "pct_full_load_loss": 0.67662528, "coupling_sequences": [[1, 2]], "winding_reactances": [7.40307669516232], "is_center_tapped": false, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "e4ea7fd7-7dd6-4aa3-b984-f4806c69c9cd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "9a9d218f-3818-4abe-9c9f-7fee34acb7cc"}}}]}, {"uuid": "43f6bef8-6670-432e-967e-238f41116cd3", "name": "", "resistance": 0.266272, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.2, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 25.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "d7f56744-2b80-450f-96df-d394c22746ae", "name": "", "resistance": 0.532544, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 0.12, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 25.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "fc204377-0430-4e39-92d8-12637b9626bd", "name": "c90ce3f4-34f4-43b1-9398-685a67188e1f", "pct_no_load_loss": 0.472, "pct_full_load_loss": 0.798816, "coupling_sequences": [[1, 2], [1, 3], [2, 3]], "winding_reactances": [2.4, 1.6, 2.4], "is_center_tapped": true, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "43f6bef8-6670-432e-967e-238f41116cd3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "d7f56744-2b80-450f-96df-d394c22746ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "d7f56744-2b80-450f-96df-d394c22746ae"}}}]}, {"uuid": "409027f9-8175-46a5-9446-3197e251f48e", "name": "", "resistance": 0.41605, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.2, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 10.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "9482a710-e97e-42d4-9afe-b8a7af1d4dd2", "name": "", "resistance": 0.832101, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 0.12, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 10.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39", "name": "4e1e5ead-0aba-4efa-8a66-7f0837cdfdb3", "pct_no_load_loss": 0.68, "pct_full_load_loss": 1.248151, "coupling_sequences": [[1, 2], [1, 3], [2, 3]], "winding_reactances": [1.08, 0.72, 1.08], "is_center_tapped": true, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "409027f9-8175-46a5-9446-3197e251f48e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "9482a710-e97e-42d4-9afe-b8a7af1d4dd2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "9482a710-e97e-42d4-9afe-b8a7af1d4dd2"}}}]}, {"uuid": "af41736a-6c75-4cfe-a051-04f517ad6634", "name": "", "resistance": 0.16642, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.2, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 75.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "a59da237-5e2b-4026-aa20-285c4f5ac91a", "name": "", "resistance": 0.33284, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 0.12, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 75.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "e2f53d7d-7442-4b42-8617-11656e408189", "name": "7069cfb8-3af7-4776-b0a7-3ee93d0a6d00", "pct_no_load_loss": 0.38, "pct_full_load_loss": 0.49926, "coupling_sequences": [[1, 2], [1, 3], [2, 3]], "winding_reactances": [2.4, 1.6, 2.4], "is_center_tapped": true, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "af41736a-6c75-4cfe-a051-04f517ad6634"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "a59da237-5e2b-4026-aa20-285c4f5ac91a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "a59da237-5e2b-4026-aa20-285c4f5ac91a"}}}]}, {"uuid": "e45fd6cc-f0ba-4fec-a6cc-8de2e6071dd5", "name": "", "resistance": 0.87204, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 3, "connection_type": "STAR", "tap_positions": [1.0, 1.0, 1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.199769053117783, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 75.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "cedafdc8-4789-49a5-b801-1112786f4229", "name": "", "resistance": 0.87204, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 3, "connection_type": "STAR", "tap_positions": [1.0, 1.0, 1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 0.27713625866050806, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 75.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39", "name": "25e347d1-54f4-4401-a111-bc5b034415d8", "pct_no_load_loss": 0.6, "pct_full_load_loss": 1.74408, "coupling_sequences": [[1, 2]], "winding_reactances": [3.24], "is_center_tapped": false, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "e45fd6cc-f0ba-4fec-a6cc-8de2e6071dd5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "cedafdc8-4789-49a5-b801-1112786f4229"}}}]}, {"uuid": "5f0d2c9e-13b8-4f29-8af9-6188720eedac", "name": "", "resistance": 0.199704, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.2, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 50.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "43ae60da-acbb-41be-b1e9-850c4e760ec4", "name": "", "resistance": 0.399408, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 0.12, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 50.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208", "name": "dcf66ff7-2c37-4071-944c-a1a7c55efdd0", "pct_no_load_loss": 0.37, "pct_full_load_loss": 0.599112, "coupling_sequences": [[1, 2], [1, 3], [2, 3]], "winding_reactances": [2.4, 1.6, 2.4], "is_center_tapped": true, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "5f0d2c9e-13b8-4f29-8af9-6188720eedac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "43ae60da-acbb-41be-b1e9-850c4e760ec4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "43ae60da-acbb-41be-b1e9-850c4e760ec4"}}}]}, {"uuid": "a0c12460-ccac-452f-9740-c1574cf5bb1f", "name": "", "resistance": 0.266272, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.2, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 50.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "f6e9a1ac-c88b-4fe2-a154-24f5f7642ecf", "name": "", "resistance": 0.532544, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 0.12, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 50.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "fac52057-f5c2-4934-9fe6-6517159b5db2", "name": "c008ed76-f669-42ff-b5cd-d16b05f9d6a9", "pct_no_load_loss": 0.472, "pct_full_load_loss": 0.798816, "coupling_sequences": [[1, 2], [1, 3], [2, 3]], "winding_reactances": [2.4, 1.6, 2.4], "is_center_tapped": true, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "a0c12460-ccac-452f-9740-c1574cf5bb1f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "f6e9a1ac-c88b-4fe2-a154-24f5f7642ecf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "f6e9a1ac-c88b-4fe2-a154-24f5f7642ecf"}}}]}, {"uuid": "777a7223-aa6f-4f59-8319-64339d066aab", "name": "93ddfc44-8481-4bdf-ab60-e9ff52bb462f", "pct_no_load_loss": 0.37, "pct_full_load_loss": 0.798816, "coupling_sequences": [[1, 2], [1, 3], [2, 3]], "winding_reactances": [2.4, 1.6, 2.4], "is_center_tapped": true, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "a0c12460-ccac-452f-9740-c1574cf5bb1f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "f6e9a1ac-c88b-4fe2-a154-24f5f7642ecf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "f6e9a1ac-c88b-4fe2-a154-24f5f7642ecf"}}}]}, {"uuid": "bd55901d-7c9b-4820-ae8e-57c9ca06328f", "name": "", "resistance": 0.266272, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.2, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 75.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "cd8890eb-9546-4f24-acce-6fcf2ee84c86", "name": "", "resistance": 0.532544, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 0.12, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 75.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "5b183af9-59bd-450e-bea6-e545db99accd", "name": "9d1848f6-5882-41b9-b2a8-c82d69262c5d", "pct_no_load_loss": 0.37, "pct_full_load_loss": 0.798816, "coupling_sequences": [[1, 2], [1, 3], [2, 3]], "winding_reactances": [2.4, 1.6, 2.4], "is_center_tapped": true, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "bd55901d-7c9b-4820-ae8e-57c9ca06328f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "cd8890eb-9546-4f24-acce-6fcf2ee84c86"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "cd8890eb-9546-4f24-acce-6fcf2ee84c86"}}}]}, {"uuid": "d7f8bb16-2fa2-44b9-9ef9-402d0cdb4de0", "name": "", "resistance": 0.41605, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.2, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 25.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "13913f15-8cf3-4455-991c-233f79168c29", "name": "", "resistance": 0.832101, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 0.12, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveVoltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 25.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "7ecefea9-516a-4cb1-8c06-cac3a09bcc5e", "name": "c3e09961-f803-4e36-b0bb-ca80f2402057", "pct_no_load_loss": 0.68, "pct_full_load_loss": 1.248151, "coupling_sequences": [[1, 2], [1, 3], [2, 3]], "winding_reactances": [1.08, 0.72, 1.08], "is_center_tapped": true, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "d7f8bb16-2fa2-44b9-9ef9-402d0cdb4de0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "13913f15-8cf3-4455-991c-233f79168c29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "13913f15-8cf3-4455-991c-233f79168c29"}}}]}, {"uuid": "cb14ae0e-2eb0-4352-9990-bab8587ecbc3", "name": "sb10_p1rhs7_1247_trans_301", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16bb904e-b153-4b0a-97f5-53ad7c6606d8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "001adbd4-6616-4dce-83d2-025e896ada51"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0ff22131-b16e-4e2e-808a-862b62584bf5"}}}}, {"uuid": "0f8211a9-3a1c-4289-91ed-70595408cdb6", "name": "tr(r:p1rdt4964-p1rdt4964lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7f13598-e628-457c-9ba6-d9a0123e882c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3541a1a-9680-4baf-9b87-a1322cb1a16a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3541a1a-9680-4baf-9b87-a1322cb1a16a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "4459a649-5f2a-49a5-ad44-234e0a27c101", "name": "tr(r:p1rdt4980-p1rdt4980lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ddb0629-4947-47ca-83f9-9b7c073db235"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab731358-e17f-4c48-b6f8-c7bb4c7701de"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab731358-e17f-4c48-b6f8-c7bb4c7701de"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "a14eb44e-8274-4874-9188-51fccadf71e2", "name": "tr(r:p1rdt5017-p1rdt5017lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c09f718-9379-4281-86f6-55c46e46aec6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0375d197-ccd2-4ed8-9439-857b700cefb8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0375d197-ccd2-4ed8-9439-857b700cefb8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f59e21f9-fe45-41c0-9dfb-d93eeb5c5a9b", "name": "tr(r:p1rdt5126-p1rdt5126lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0dafde2-c08e-4624-9212-e0fea9e47c2c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e33e473-8d5b-4704-bdab-56032991f94e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e33e473-8d5b-4704-bdab-56032991f94e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "a224a322-e724-45d6-b4de-232506f9f06e", "name": "tr(r:p1rdt5140-p1rdt5140lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b0fd055-d0ac-4678-a8e5-679e12741736"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f114a56-98d7-4fe8-b0b1-b8c4bc791cf9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f114a56-98d7-4fe8-b0b1-b8c4bc791cf9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "8d206fac-69f4-4fad-9199-94c1209314a0", "name": "tr(r:p1rdt5142-p1rdt5142lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d579047b-82f6-49bf-bd7b-28c818d44bb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e071635-4071-470d-be09-4484cb90441a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e071635-4071-470d-be09-4484cb90441a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "316c1908-f8c8-4724-99c8-68acd6ca28e6", "name": "tr(r:p1rdt5153-p1rdt5153lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb8dae66-287a-4b8a-9cda-6ae02cb8f8a9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ec20ad2-b04f-43fc-ad8d-d41746549a57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ec20ad2-b04f-43fc-ad8d-d41746549a57"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "f6e301fe-1473-4823-8abc-5bb307b2ce1a", "name": "tr(r:p1rdt5154-p1rdt5154lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50332aed-ecfd-465a-977e-c24ed6462860"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9750085f-4afd-48ee-89f3-edbe9687b242"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "5e034209-8f4d-4112-bf2e-fc5d831d0b41", "name": "tr(r:p1rdt5155-p1rdt5155lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16712e10-4c7f-428b-917b-135ab3c2d4b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85351f49-cb19-4f71-a6ae-a21f5a48af6f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85351f49-cb19-4f71-a6ae-a21f5a48af6f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "5a444dd7-7ccc-4ad8-bdb1-e278ecb6ab5b", "name": "tr(r:p1rdt5159-p1rdt5159lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90fb2270-4759-4779-80c1-7f93d66e1c53"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba7e3a6b-f62f-432f-afe7-2ebbfc9abd59"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba7e3a6b-f62f-432f-afe7-2ebbfc9abd59"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "224f6b7f-ed33-4683-96f3-f5463456d1f4", "name": "tr(r:p1rdt5172-p1rdt5172lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ea481f8-b9c7-4067-9bfb-4f7cdc5dee15"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48efdcb9-083c-4e17-a1d2-acb1388f085e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48efdcb9-083c-4e17-a1d2-acb1388f085e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d096b871-d8cf-49e3-a9d8-bce4ee870d37", "name": "tr(r:p1rdt5179-p1rdt5179lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d22f1247-b756-4498-8cf8-fef7d1e859ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd4155b2-ca55-41d7-bd35-98a5eec8c39a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd4155b2-ca55-41d7-bd35-98a5eec8c39a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "03f5affd-877c-44f3-a574-df7d0a34d7bf", "name": "tr(r:p1rdt5180-p1rdt5180lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6316fa2-dd57-46d4-89c0-f11dd675d686"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae26acb3-c2c9-479c-9d19-c30bf00aa8c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae26acb3-c2c9-479c-9d19-c30bf00aa8c5"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "1b56638f-139e-4db8-93ee-87c32a4330ef", "name": "tr(r:p1rdt5183-p1rdt5183lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23f0bb81-3c30-45a5-89ca-2011e3881ddb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bbde2e8-42c0-486b-9759-78898d177f93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bbde2e8-42c0-486b-9759-78898d177f93"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4d397307-5f03-484b-bb97-2343016c603d", "name": "tr(r:p1rdt5184-p1rdt5184lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "431b672b-cb45-4294-b1f9-1d63f4efc8db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1656cc28-8a5b-40da-887f-25605dd336aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1656cc28-8a5b-40da-887f-25605dd336aa"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "7cee3b1b-3e70-4066-ae18-13419331a26b", "name": "tr(r:p1rdt5195-p1rdt5195lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58c6d858-d457-4fe6-a45b-b9b2b73cad8c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf05c1bb-39cc-48b3-a576-18913e0cff13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf05c1bb-39cc-48b3-a576-18913e0cff13"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "39039b81-4e2f-42c7-b890-1bf3d089058a", "name": "tr(r:p1rdt5200-p1rdt5200lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "799ab435-c0a4-4515-8125-e8ca2fb7632d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "03e7bfdb-ff8b-4142-95ef-8d848ff5d2db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "03e7bfdb-ff8b-4142-95ef-8d848ff5d2db"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "02b53edb-2e1f-4263-9d58-d6f7837fee8b", "name": "tr(r:p1rdt5201-p1rdt5201lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c289632-ba52-4b65-b6da-ac76b1477246"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8162a8c-5339-4f42-bd7a-b6dbc5ff463b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8162a8c-5339-4f42-bd7a-b6dbc5ff463b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "403188b7-0c92-46b1-b0a0-72798d290fa2", "name": "tr(r:p1rdt5202-p1rdt5202lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97e4f179-9d60-4183-8326-eb0ab98a53eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "39eaedd7-75b6-449f-8ff6-6e31f6e74504"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "39eaedd7-75b6-449f-8ff6-6e31f6e74504"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b875dd86-44ae-41fc-b621-1d50fd1369ab", "name": "tr(r:p1rdt5206-p1rdt5206lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ed081eb-6b56-43b8-9cf8-e7ffdd8222f2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "599a2995-33d5-4bcc-8cd3-585ea37577cd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "599a2995-33d5-4bcc-8cd3-585ea37577cd"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "cfd7929a-5a92-40d0-8117-68f69e67d917", "name": "tr(r:p1rdt5218-p1rdt5218lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dda7f7c-3b21-46a0-88a3-2b7f028b7772"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c650eda9-132b-4419-a055-ad68037c7772"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c650eda9-132b-4419-a055-ad68037c7772"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "e226528d-6510-43cc-9946-faedc99958f7", "name": "tr(r:p1rdt5236-p1rdt5236lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22db53ea-6d9a-4527-9b36-34a4bcd2c74f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f252d81-66ee-40a6-bce7-2891e06b39e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f252d81-66ee-40a6-bce7-2891e06b39e4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "897a5ce1-914d-454b-a71c-5980ff30cc2f", "name": "tr(r:p1rdt5342-p1rdt5342lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c8f9ea6-06fb-4fd0-8629-ceea4f32189f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e01069aa-388b-4362-9d02-a164f173dc20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e01069aa-388b-4362-9d02-a164f173dc20"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "519868f4-b58e-4fdc-b749-5324585674fa", "name": "tr(r:p1rdt5472-p1rdt5472lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a8c3f7f-b9be-4c5e-b6f0-8f2fc18935fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34a1276e-c702-4c69-b7b1-566d400da2de"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34a1276e-c702-4c69-b7b1-566d400da2de"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "3afcd18e-c615-4125-9695-1bf38cf70f51", "name": "tr(r:p1rdt5475-p1rdt5475lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b9e57e0-6dc8-4831-ac7d-36f8608b7a8d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d181674-9355-488b-8a3f-5b7c844c35a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d181674-9355-488b-8a3f-5b7c844c35a5"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "5cd3e55d-3396-480b-b9cd-00b92b563c79", "name": "tr(r:p1rdt5476-p1rdt5476lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b077dc9c-1c6f-4403-ae0c-954e7cc0c692"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0888f4c5-e037-4891-99fb-fd43934ffae0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0888f4c5-e037-4891-99fb-fd43934ffae0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "38e532e3-559a-4907-853d-7cd08b7d5493", "name": "tr(r:p1rdt5477-p1rdt5477lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7d7f462-1ab5-4fd8-baaa-7e576eead5c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fafd64c3-efe5-4684-b06f-44e4c8555aa4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fafd64c3-efe5-4684-b06f-44e4c8555aa4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "473cf7e7-cc10-4402-a7d2-42b4288be59b", "name": "tr(r:p1rdt5478-p1rdt5478lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a97491e-2c98-4584-9b74-5593f17faeda"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5107bc9c-f463-49f6-a92f-23c5730475e2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5107bc9c-f463-49f6-a92f-23c5730475e2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "f3d168ab-98b0-4f71-a258-4db4b923422f", "name": "tr(r:p1rdt5480-p1rdt5480lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2568f11c-8a37-4a55-8bce-9f0d56ac386a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44ac9e38-8ae3-4102-822b-1c638a6c878a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44ac9e38-8ae3-4102-822b-1c638a6c878a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6ab40212-5945-4e0d-be6c-547813180165", "name": "tr(r:p1rdt5481-p1rdt5481lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d29d8b74-a24d-4474-9752-c1ffa1aa7f7c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f213ee9e-6ae7-4e82-9f25-6fc456f45576"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f213ee9e-6ae7-4e82-9f25-6fc456f45576"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "804a9ecc-be85-4926-84d2-1879c6008a6e", "name": "tr(r:p1rdt5483-p1rdt5483lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f903015c-95a7-4d6e-b2a5-e9705c050c6e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a73d544-9f33-49d9-b648-c806addf3c06"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a73d544-9f33-49d9-b648-c806addf3c06"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "e47a7160-32cb-47d7-a35d-f30bb1d87bc9", "name": "tr(r:p1rdt5485-p1rdt5485lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cfb3a23-3a93-4d89-8b70-e4730ebbce1a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40eaefce-482f-4a89-bec1-2c11bac2bfb7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40eaefce-482f-4a89-bec1-2c11bac2bfb7"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "3c03d8f3-d40a-4b30-8f4b-39116f72993e", "name": "tr(r:p1rdt5650-p1rdt5650lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8f1c67e-9e29-45a3-a2a3-c2f3493a6898"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28a6e44b-c6c7-4556-b4d8-d55359391c66"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28a6e44b-c6c7-4556-b4d8-d55359391c66"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "442a6df8-1877-4263-a9de-b6a18ae053ad", "name": "tr(r:p1rdt5653-p1rdt5653lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "769c14db-ac3f-438d-9f7d-c7eb2d3074b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38d1de19-1f51-4875-acc2-a75e3d1a290e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38d1de19-1f51-4875-acc2-a75e3d1a290e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b88a89f2-d5e8-45bd-939b-2476952d2902", "name": "tr(r:p1rdt5656-p1rdt5656lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f417a58d-5a47-4310-bac6-e8bb95fffc19"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "87e8c57e-67ff-439c-b28b-0fbdbfd62ea6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "87e8c57e-67ff-439c-b28b-0fbdbfd62ea6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "a62dc441-3832-46a8-9fe3-5ad01441938c", "name": "tr(r:p1rdt5658-p1rdt5658lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81d6db26-881f-4cae-9514-df4c1e71c76e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f718935b-704d-4374-9172-856511e1eddd"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "1bc7dee2-3a73-4bf6-b9e5-5a51eb44b4ff", "name": "tr(r:p1rdt5662-p1rdt5662lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17e89212-bc51-4fc2-83d1-4c74a285be23"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea73a91a-b052-486e-810b-1a5ad281e07b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea73a91a-b052-486e-810b-1a5ad281e07b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "48c1ed45-922f-4c58-b9d0-26d6c91138f3", "name": "tr(r:p1rdt5663-p1rdt5663lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7356d982-36fd-46cb-9300-8889502e8dc8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16a67a88-5d11-4eca-85fe-38c948ad362c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16a67a88-5d11-4eca-85fe-38c948ad362c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "85ffc857-6af0-4a86-bcdd-734da36e5718", "name": "tr(r:p1rdt5728-p1rdt5728lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b55c58cf-153e-4aa3-b099-8a1db05a6ae5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6d456893-4d89-455a-b1a5-4863aad6293a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6d456893-4d89-455a-b1a5-4863aad6293a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4f92fde2-27d2-48b7-aab1-425ccf2fedee", "name": "tr(r:p1rdt5729-p1rdt5729lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "77d2122b-cbb7-4844-bbb2-55e939431e50"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95f81d7a-a6af-4843-bfa1-002abc7ff870"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95f81d7a-a6af-4843-bfa1-002abc7ff870"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "0783f792-d931-4d06-a008-d6dff90de5cb", "name": "tr(r:p1rdt5730-p1rdt5730lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5897bb2-1f72-4aeb-9090-74e2411b5786"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2dd206bc-965d-46c9-8fdb-8c158c7bba05"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2dd206bc-965d-46c9-8fdb-8c158c7bba05"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "5a2f8d06-f5c2-4ff9-befb-b1580884d748", "name": "tr(r:p1rdt5731-p1rdt5731lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95cd61cf-f1cb-4af2-9d3b-e42978642003"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e414162-eda7-4cf2-9116-fc24af9461bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e414162-eda7-4cf2-9116-fc24af9461bf"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6d3ddf78-01dd-4545-865b-513b8a016d38", "name": "tr(r:p1rdt5840-p1rdt5840lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35722d90-049e-4c67-9654-acce0572e6c2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9974869d-7d87-4a27-9606-076cd7799953"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9974869d-7d87-4a27-9606-076cd7799953"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "7a69c32d-25c9-4ba6-9763-bc883b42aec6", "name": "tr(r:p1rdt5923-p1rdt5923lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fec8a81-a151-4d8f-adc7-6d6d87d7759f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "751d2f2e-bb6f-4ca6-9e86-0e2b5ff3f92a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "751d2f2e-bb6f-4ca6-9e86-0e2b5ff3f92a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "7c2647c5-6bca-4086-b50e-8dc4d3699dd7", "name": "tr(r:p1rdt6038-p1rdt6038lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8898950-d712-40dc-99b5-33882b96b225"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d654945d-b71d-4943-86a2-5830fca200c9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d654945d-b71d-4943-86a2-5830fca200c9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4f7e809a-a82d-4bf0-ac51-229280ce4fd9", "name": "tr(r:p1rdt6043-p1rdt6043lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "87e05b2f-c346-452c-9c72-a6db090c3124"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ae7bbf-f53e-4ae2-8145-bf56ce935094"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ae7bbf-f53e-4ae2-8145-bf56ce935094"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fac52057-f5c2-4934-9fe6-6517159b5db2"}}}}, {"uuid": "df4304d6-f35e-4caa-b702-71b3da08c77f", "name": "tr(r:p1rdt6045-p1rdt6045lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0396342e-2dc8-4a01-9da9-513953f9b5fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70bad714-71c1-4341-ac40-76312417dd03"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "1fda4c61-98bf-494b-a4be-a77eef41867b", "name": "tr(r:p1rdt6046-p1rdt6046lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67bc3ce6-e23d-4899-b0e8-9783225338ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2e2d1a7-039c-4b29-a061-b814ac675e3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2e2d1a7-039c-4b29-a061-b814ac675e3b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "123088f7-943a-4feb-845b-85900240a87f", "name": "tr(r:p1rdt6047-p1rdt6047lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34a9d21e-bcf7-4266-9834-60a72878ddd4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21e75ccd-7e21-4f0d-890c-81aa6b33b109"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21e75ccd-7e21-4f0d-890c-81aa6b33b109"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "62ef838d-937e-4760-aabd-f8478054f480", "name": "tr(r:p1rdt6052-p1rdt6052lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c10f182d-aa76-4633-9a84-f41e20b97da1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d830a1b-6971-4f4d-99bd-945e0785b5aa"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "e1db1007-4c7e-413b-9d88-ee84e9bd8284", "name": "tr(r:p1rdt6208-p1rdt6208lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdfc617f-fbfb-4e9a-862e-cd5a296748cb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01be483b-09f4-450e-a39d-78692c40ee8b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01be483b-09f4-450e-a39d-78692c40ee8b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b0843684-b05b-4654-bc0e-d00707551a2b", "name": "tr(r:p1rdt6221-p1rdt6221lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0809ec5e-d36f-4bea-91b3-962ad6c29606"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73f78740-2ec5-4ad8-b7fb-40f4a72b730e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73f78740-2ec5-4ad8-b7fb-40f4a72b730e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "cf49bac9-27de-4e9d-98a7-f4a7be482fcf", "name": "tr(r:p1rdt6226-p1rdt6226lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d81fc6d7-3400-41d4-91d7-b350d7def98d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3154eee7-a1ba-4b9d-9e91-bab55529d358"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3154eee7-a1ba-4b9d-9e91-bab55529d358"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f910561f-ff5c-4353-ad1e-f22354339f22", "name": "tr(r:p1rdt6268-p1rdt6268lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2f8b91d-339f-4151-90df-b0cad5c2f05a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72ce0706-6b32-4b4b-9bf3-fd1f5a6af5ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72ce0706-6b32-4b4b-9bf3-fd1f5a6af5ca"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "d630f404-730d-43bf-adf8-c8d3a01cf56a", "name": "tr(r:p1rdt6269-p1rdt6269lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5ef97a6-6c60-46eb-acce-6469b273658a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79c91fa8-15ad-4e8d-96bd-2cad395dd280"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79c91fa8-15ad-4e8d-96bd-2cad395dd280"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "194e335f-7fd7-49b3-8533-23c4e6813e0e", "name": "tr(r:p1rdt6270-p1rdt6270lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cf36152-b3af-49f7-b693-5d465db1f283"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5adb2083-3d46-48a7-8996-37c0781b0215"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5adb2083-3d46-48a7-8996-37c0781b0215"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "cbbbeabe-626d-49b9-8577-1ddaec69fd68", "name": "tr(r:p1rdt6271-p1rdt6271lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a75c5e2-2277-42b4-87d4-6eadff5c06f1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1335e64c-9f37-4e73-a37f-8f76737cabff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1335e64c-9f37-4e73-a37f-8f76737cabff"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "74954554-5d2e-4b28-bb8d-40c669296046", "name": "tr(r:p1rdt6272-p1rdt6272lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "034bda10-d48e-449c-9255-247cbf718683"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04422e0a-1952-422d-a201-5fafef1875db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04422e0a-1952-422d-a201-5fafef1875db"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "cd6959a3-3d4c-4eae-aeee-0c9406c769c6", "name": "tr(r:p1rdt6273-p1rdt6273lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d04f281-f394-432b-8b5c-cc1acb741369"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07992f45-0c92-4a10-837d-4f58599d9b75"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "55aac547-fb88-4aa6-8809-ecd9a876ffa4", "name": "tr(r:p1rdt6274-p1rdt6274lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a53624b-8538-4cce-b588-c774875af31b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1db8c80-e791-4c31-a6f2-713aa665bf41"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1db8c80-e791-4c31-a6f2-713aa665bf41"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "0ba41d6b-5061-4da6-a3ac-bb25ac6bf459", "name": "tr(r:p1rdt6275-p1rdt6275lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08d4c459-5bc5-4cad-8e74-613c4a08cb35"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba567584-fbee-44eb-b3f1-da24a0ce66a0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba567584-fbee-44eb-b3f1-da24a0ce66a0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "0dd85bf1-32ee-4efa-9b79-2c455df5d785", "name": "tr(r:p1rdt6276-p1rdt6276lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "315af04d-a032-43a8-a2da-b9e68fd21f39"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f20ace2-5ec8-4451-b7e7-66f46c2c487b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f20ace2-5ec8-4451-b7e7-66f46c2c487b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ecf6f04d-159d-4f51-bf3e-799ca3b33afb", "name": "tr(r:p1rdt6277-p1rdt6277lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1dd4f893-7921-41c3-9e9e-d33e3680a999"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e582b04d-a8d8-4ee9-8576-1e5941623c0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e582b04d-a8d8-4ee9-8576-1e5941623c0b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "8e37ba75-2f21-4e53-a316-b5fab0dd5024", "name": "tr(r:p1rdt6278-p1rdt6278lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51eefb94-724e-4dfe-9823-0f6cf8f56101"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b37eabc-787a-491f-bc4f-956f43a862ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b37eabc-787a-491f-bc4f-956f43a862ff"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4a4f2957-d5d5-4b14-b64a-3c47edce713f", "name": "tr(r:p1rdt6279-p1rdt6279lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "632d8db5-5220-4188-94f0-f6131253820b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6614f5e-517f-46cf-b049-09337d57228a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "6f6b8188-d30e-42a1-93eb-2a1b1bc0bdad", "name": "tr(r:p1rdt6345-p1rdt6345lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40280da5-767c-4610-b6a8-ff411e1c33e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a38eb6d-a625-42a1-95f6-bbf078d1447a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a38eb6d-a625-42a1-95f6-bbf078d1447a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "70aa8f42-99ed-452a-b36c-f06fa56744da", "name": "tr(r:p1rdt6347-p1rdt6347lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7166849-6ecd-4270-bf52-d0579838336a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e40008af-ff50-42bd-8897-f663c27a436f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e40008af-ff50-42bd-8897-f663c27a436f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a13e6c46-4605-4824-91c2-352fb915a87b", "name": "tr(r:p1rdt6348-p1rdt6348lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d6c5b78-35c4-475a-8837-776dea236c95"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d84ac329-f314-41be-a2ee-89bc74789a18"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d84ac329-f314-41be-a2ee-89bc74789a18"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "4ff0e214-7067-4064-9386-9806caf80eaf", "name": "tr(r:p1rdt6349-p1rdt6349lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c1edcfa-e0e4-4493-a9bb-e6033185ce67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdfa0310-7dc5-4181-a64e-cc2522370547"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdfa0310-7dc5-4181-a64e-cc2522370547"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "11b74794-1c6f-47e4-a54f-433e3831c90c", "name": "tr(r:p1rdt6350-p1rdt6350lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c935f1c0-e36c-407d-a2e8-4181c4b0733e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0138b892-d18e-497c-9857-c4d5676deac2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0138b892-d18e-497c-9857-c4d5676deac2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4cd1169b-f163-4253-b934-0f8715170853", "name": "tr(r:p1rdt6353-p1rdt6353lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e51e0d9-24b6-40ac-859a-51ea74c93e76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "015322ae-7712-488f-9569-33fc785e4f62"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "015322ae-7712-488f-9569-33fc785e4f62"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c6442bf3-7517-47a1-a505-20f615795f42", "name": "tr(r:p1rdt6354-p1rdt6354lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a05e7c9-4bff-46fd-b356-8120b481b053"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f06a08bd-05ea-4914-b0d0-07cd0e83bfbc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f06a08bd-05ea-4914-b0d0-07cd0e83bfbc"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a2e09203-34e7-4304-9ef8-79ced26ee5cf", "name": "tr(r:p1rdt6355-p1rdt6355lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "88cc1382-6b14-4500-8a21-662fce6a0c0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1d14a79-4d18-43fe-8790-57ea9adf83a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1d14a79-4d18-43fe-8790-57ea9adf83a8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "7a9d98cb-9394-474e-837a-3acb6f94652b", "name": "tr(r:p1rdt6356-p1rdt6356lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1bdfc1ac-98a4-43dd-bb2c-837d0a2c15f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "548724aa-110a-428f-b71a-acdf0051dc39"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "548724aa-110a-428f-b71a-acdf0051dc39"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "058d6f19-56cc-412c-b1e5-cbcabe0dc8ca", "name": "tr(r:p1rdt6409-p1rdt6409lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42929633-40d4-4e13-a0aa-a7682f328226"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e36cfaaa-3996-4cc6-aa4f-170f20c5d1e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e36cfaaa-3996-4cc6-aa4f-170f20c5d1e0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a340529f-91b6-49c6-9dca-e2917c92ce4f", "name": "tr(r:p1rdt6498-p1rdt6498lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5c5466f-b7e4-4844-967b-9e8b11c68b44"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "e9dd0225-3992-43ea-8011-c92f7dd12ae0", "name": "tr(r:p1rdt6499-p1rdt6499lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "89434ebc-1e79-4414-9925-1a14f8e72fd6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb05d831-1556-4f56-8065-d9d16657caa3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb05d831-1556-4f56-8065-d9d16657caa3"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "78d55ca8-45d5-442d-8aff-41943123d90d", "name": "tr(r:p1rdt6500-p1rdt6500lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78b3b940-c277-441f-b2b3-83525ed85fcb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a20a4242-8a76-49f3-9bf5-3d7aaf751cdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a20a4242-8a76-49f3-9bf5-3d7aaf751cdc"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "4f669b5d-d8e9-463a-b26f-2a4ee9987301", "name": "tr(r:p1rdt6501-p1rdt6501lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99fa55d1-867c-4db0-8697-b532da10d6d4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "5b183af9-59bd-450e-bea6-e545db99accd"}}}}, {"uuid": "34a8f0cc-8b8d-4cbe-a72c-4953ada66769", "name": "tr(r:p1rdt6502-p1rdt6502lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e6348d4-7fcb-4546-af84-8ece75b6332f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7682e9f7-1272-4781-b128-34c7329afe49"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7682e9f7-1272-4781-b128-34c7329afe49"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d400dd14-c9f5-47a1-b904-0451078eb91b", "name": "tr(r:p1rdt6505-p1rdt6505lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb1c1e50-902d-443d-8c9a-b728d2f6b6f1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387e7785-8d40-4ddd-8c2b-14a83d4e7401"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387e7785-8d40-4ddd-8c2b-14a83d4e7401"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "aa0dde85-1b90-4171-9964-b45e0fba3d62", "name": "tr(r:p1rdt6507-p1rdt6507lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0db3e719-4dba-4b45-af70-c35546c19eb4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5844baa-5e0f-4edd-9122-fe4255adad0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5844baa-5e0f-4edd-9122-fe4255adad0b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "30e44c45-a02c-4cea-8908-3cc302637263", "name": "tr(r:p1rdt6508-p1rdt6508lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e165d0d-3f13-4d87-9c4b-fdfa8829f1f3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "e492a34f-e6bb-4fe5-81a5-90fd87eabde0", "name": "tr(r:p1rdt6509-p1rdt6509lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67c889f-e940-4242-9c83-4b5ab673d8a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f817a28f-c650-4eb4-84c0-751fe5053c75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f817a28f-c650-4eb4-84c0-751fe5053c75"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "c9ced24a-5b5b-4df7-8d09-09dd0242098b", "name": "tr(r:p1rdt6510-p1rdt6510lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "848c04de-e4d5-4520-9dce-0073776c2ae4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d62fe3b-7644-46d1-8a15-e86d95ae8b2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d62fe3b-7644-46d1-8a15-e86d95ae8b2a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "5b183af9-59bd-450e-bea6-e545db99accd"}}}}, {"uuid": "c4d3abcf-3d44-4600-8d3d-8ecbac558601", "name": "tr(r:p1rdt6512-p1rdt6512lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f7572ed-6443-4e6e-8fb8-0b060b9f17ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "c95fd30e-d8ee-4e73-8137-8809191cc304", "name": "tr(r:p1rdt6514-p1rdt6514lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0737f6ec-0d5d-4cff-b4b7-9910c7076984"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad6bef77-8f39-43b4-b2d7-58aa6e45a60b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad6bef77-8f39-43b4-b2d7-58aa6e45a60b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "f8a778f3-59c0-4bec-8421-fe311691a98e", "name": "tr(r:p1rdt6515-p1rdt6515lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1537ab1-dc7c-4bbd-b347-fc740d54fcf7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b92f8bcd-91ce-42bd-be69-0b43cb9d4122"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b92f8bcd-91ce-42bd-be69-0b43cb9d4122"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "04865f1a-c24c-4c01-9c2c-2f0900f03c59", "name": "tr(r:p1rdt6516-p1rdt6516lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5bd908fd-8bb8-42c1-8d1b-27c4e2574450"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "119a8559-8e6c-4314-9bbd-37ef3adde415"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "119a8559-8e6c-4314-9bbd-37ef3adde415"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "28fdc699-4ca3-4224-ab12-104819ba90f7", "name": "tr(r:p1rdt6517-p1rdt6517lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b56340a0-81f0-4028-9283-532f0d92a412"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5783bae9-2c74-473f-bf18-db40bc975409"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5783bae9-2c74-473f-bf18-db40bc975409"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f389fc04-f3b3-4f77-9b76-fd9e9c700eab", "name": "tr(r:p1rdt6518-p1rdt6518lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d39c608-5688-4e22-8ac4-96b896265274"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b16b03-1922-4aeb-8e70-d0e1387fbcab"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b16b03-1922-4aeb-8e70-d0e1387fbcab"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "ef0eea90-233c-45ea-8067-2c1f4945c601", "name": "tr(r:p1rdt6519-p1rdt6519lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "addd9f38-279f-4d9e-b216-38faef1940c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "606673ea-bcd2-459a-a0af-efb8b31c600c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "606673ea-bcd2-459a-a0af-efb8b31c600c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "59e61f1f-ded0-4c99-a73c-1f0eece1beda", "name": "tr(r:p1rdt6520-p1rdt6520lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24028ccd-3fd3-4461-b83c-54266f91a385"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13c02cd3-cff3-4988-95b9-3993b9541427"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13c02cd3-cff3-4988-95b9-3993b9541427"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "d566312d-edfe-48bf-928b-511d9fa3d857", "name": "tr(r:p1rdt6521-p1rdt6521lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "302d2adf-2199-47b2-9f3c-e428bb409b6f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0e4e42c-8dcd-47be-bfe8-b8b1eb4a5f24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0e4e42c-8dcd-47be-bfe8-b8b1eb4a5f24"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "01a96d6a-0929-49a6-b5bb-16ac567b9a88", "name": "tr(r:p1rdt6523-p1rdt6523lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b540c710-395d-4a35-8dc3-59d37609df09"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66df2481-ae4f-4f39-aef4-7af09ce1a8fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66df2481-ae4f-4f39-aef4-7af09ce1a8fb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "4121aff5-c528-4441-9261-8852d46e58af", "name": "tr(r:p1rdt6524-p1rdt6524lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ef8c502-c06f-43e5-90e6-23bd0ebcf155"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ec2137a-f978-4808-a023-21f13464998b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ec2137a-f978-4808-a023-21f13464998b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "0913bb9f-6019-467a-9487-635b1c029c69", "name": "tr(r:p1rdt6527-p1rdt6527lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "483b2d65-b496-4c6f-b01d-66aa3d9d4334"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8905812-7e3b-4875-87b5-da95999c5bb0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8905812-7e3b-4875-87b5-da95999c5bb0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "516355b6-65e5-4e7f-96cc-f5f66a86fee1", "name": "tr(r:p1rdt6528-p1rdt6528lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ef5115d-ad7b-4671-b984-b9fd5969bf61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d097d9be-dd3a-4616-a873-8ab5013c4e72"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d097d9be-dd3a-4616-a873-8ab5013c4e72"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "314abd89-9ffb-4e76-bde9-35cd4f3410d0", "name": "tr(r:p1rdt6530-p1rdt6530lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40ec7437-80f0-49e8-806a-c696b1402713"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4ee2d3a-e97c-4ec4-9fa0-d7db1b3e9253"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4ee2d3a-e97c-4ec4-9fa0-d7db1b3e9253"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1e893589-336e-4ed7-ae34-9ffb1e76b82b", "name": "tr(r:p1rdt6531-p1rdt6531lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "385eabe4-8c8e-4354-96ec-931e6c25574d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf4a2da0-682a-4119-b398-feaa6f5a8498"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf4a2da0-682a-4119-b398-feaa6f5a8498"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "aaf01e94-e631-4cbd-9b80-5dd82eae3e7f", "name": "tr(r:p1rdt6532-p1rdt6532lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9f12ed7-454c-4cc9-a631-377121a07ba5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0c3e71a-52a1-49b9-a899-c13d639ac0a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0c3e71a-52a1-49b9-a899-c13d639ac0a6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "16c6d40c-8621-46f3-a9d9-eb9f155486b7", "name": "tr(r:p1rdt6535-p1rdt6535lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b13053e-033e-4fe9-8eb3-89389e4bdc2b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10f0e9fa-75b8-4eaa-a2ad-b6a3fb4ae859"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10f0e9fa-75b8-4eaa-a2ad-b6a3fb4ae859"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "1636c5ab-0f83-47b9-b0b9-95c17d558f42", "name": "tr(r:p1rdt6536-p1rdt6536lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f5cda74-5e33-4c52-8b2c-76bcd5e6c5cb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b93e7299-60a4-49d6-9d34-885860588861"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b93e7299-60a4-49d6-9d34-885860588861"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "81e7d228-2f50-4e9c-a1a5-06c06422eaec", "name": "tr(r:p1rdt6537-p1rdt6537lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "902291fa-9561-4f40-a4b7-4fd9fdded417"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3f191ff-f8f2-4f13-af83-e67d1fdd366a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "a14a1967-2de3-44cf-b403-5c2c78717e13", "name": "tr(r:p1rdt6539-p1rdt6539lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9707f264-8f82-4483-8337-6c89d709faf7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b34f50ff-9a1f-439e-81a8-dfcee658926b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b34f50ff-9a1f-439e-81a8-dfcee658926b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "0982378f-fc34-40cc-8889-8feb46b3d3a3", "name": "tr(r:p1rdt6574-p1rdt6574lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25a9ec20-35b9-4262-a02d-cafa63e5ee42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a43920a-a200-40fe-b5b6-3cdba0c7e784"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a43920a-a200-40fe-b5b6-3cdba0c7e784"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "078928ee-8198-4b34-9e44-3d2464af89ec", "name": "tr(r:p1rdt6581-p1rdt6581lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "599c6ed9-5ff7-4c97-a469-adceecaaf902"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "608e485b-13ce-493b-be96-ab83ad733c92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "608e485b-13ce-493b-be96-ab83ad733c92"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "f15ffb13-3e9f-44b6-9603-dab244b5181f", "name": "tr(r:p1rdt6847-p1rdt6847lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e92b102-eaee-41cc-a2fc-c6c4b3bfb58b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7b9897e-b820-424c-adf8-7416de585357"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7b9897e-b820-424c-adf8-7416de585357"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "e3df7eb1-aff6-4359-acc7-d144d166201d", "name": "tr(r:p1rdt6848-p1rdt6848lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96399e51-1243-4e7f-ae3a-5e2c67123aae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94c9fa37-fc5c-4243-b0ca-f70840febaee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94c9fa37-fc5c-4243-b0ca-f70840febaee"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "d992636b-1b45-4cf4-9b69-e4a53bf53fdf", "name": "tr(r:p1rdt6995-p1rdt6995lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3741c9d4-d03a-4b2f-be57-52a8977351ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09a476ff-48a0-4d27-9cf0-c007e2e98acb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09a476ff-48a0-4d27-9cf0-c007e2e98acb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6973bac5-8bc7-4183-ac29-4d1c42f19e00", "name": "tr(r:p1rdt7015-p1rdt7015lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6278a0d-f5d3-4b11-aee9-3bb23f9954a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "536d7c56-85a6-4167-b4f6-2f39936cd662"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "536d7c56-85a6-4167-b4f6-2f39936cd662"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a0c75282-007a-41ab-9904-5fad1ba4ac01", "name": "tr(r:p1rdt7036-p1rdt7036lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52068090-b613-46d7-a31f-ad3ca26382d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a371c8b-1993-432c-b2c6-21b18bec27da"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a371c8b-1993-432c-b2c6-21b18bec27da"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "2d40d74c-19e5-4154-811a-bf6f0c3b4793", "name": "tr(r:p1rdt7038-p1rdt7038lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb3a9847-70d0-4004-95ef-63884c6c1cdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "046f6c53-8d9c-43a1-88ce-169ade9e9557"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "046f6c53-8d9c-43a1-88ce-169ade9e9557"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "57d5d60c-4bbd-4830-b62b-aef430bbbb13", "name": "tr(r:p1rdt7046-p1rdt7046lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9bb8596a-bcb2-4282-bf1b-9939a9af87d9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cd6a9808-9889-4f16-825d-c9763357c293"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cd6a9808-9889-4f16-825d-c9763357c293"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "88d0b3b4-df75-431e-a234-b9c4c40cd0f7", "name": "tr(r:p1rdt7054-p1rdt7054lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3cf406b-69e6-4aee-a6fc-272dad7693a4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf93e681-3ab6-4929-95f1-1da6d5dd28fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf93e681-3ab6-4929-95f1-1da6d5dd28fa"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9d5af3ee-6de8-428a-bce8-ff4ba5108c9f", "name": "tr(r:p1rdt7061-p1rdt7061lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75947ffd-3765-443b-bef8-b6af746ef624"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc33ade7-4471-40b8-8e9b-1846e0ad60e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc33ade7-4471-40b8-8e9b-1846e0ad60e8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "7b8e2373-7990-4ad0-ac7b-fea580be3edb", "name": "tr(r:p1rdt7067-p1rdt7067lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b470fa62-70d4-4cc5-8f7e-b9cda37481e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ff878e1-3143-4f8e-aa92-74d0a9046417"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ff878e1-3143-4f8e-aa92-74d0a9046417"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "c5a5b6ad-87d0-4856-83d7-f4e3fd1bf17a", "name": "tr(r:p1rdt7069-p1rdt7069lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aae22557-7d34-401d-82c9-2d2710ff2915"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a1566f1-7f0d-41d7-adad-425c9a344eb0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a1566f1-7f0d-41d7-adad-425c9a344eb0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "74945b57-66b3-460b-8963-4876d9317ea5", "name": "tr(r:p1rdt7070-p1rdt7070lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac6e8ccf-75ec-42e0-a3cb-9ab86e2731a4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "844bdc22-2e32-43ee-8e0b-26f3f4c107b8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "844bdc22-2e32-43ee-8e0b-26f3f4c107b8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "56ede37f-8654-4ee4-98d5-b4ca3c882a01", "name": "tr(r:p1rdt7075-p1rdt7075lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8cebb186-4d9e-4d2c-b0d9-100056d34942"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e0577c2-8275-4303-ad11-2c4f56df3f5c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e0577c2-8275-4303-ad11-2c4f56df3f5c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "3c44ca10-17d2-4bc0-8731-abfad4747034", "name": "tr(r:p1rdt7080-p1rdt7080lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "662e2a1c-9a54-4ac3-b478-98e3a478349d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d86bd7f-7759-4d74-9c74-d58010498f92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d86bd7f-7759-4d74-9c74-d58010498f92"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "23574f4e-125b-4c27-9e9f-edd96225a600", "name": "tr(r:p1rdt7087-p1rdt7087lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f614382d-3883-4f6b-b1f6-c8e83d84ee22"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d0c96fe-78c2-4303-ac5c-bbe440f19666"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d0c96fe-78c2-4303-ac5c-bbe440f19666"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "fe0147a8-371a-4e44-a456-842e99895e5b", "name": "tr(r:p1rdt7088-p1rdt7088lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac70c13b-5f4f-45f3-880a-b4b476ea552a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f1652e8-6cf7-43d4-8474-e61a74873675"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f1652e8-6cf7-43d4-8474-e61a74873675"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "49996ff9-e4f6-4f1f-abb7-8f8f1d042cb6", "name": "tr(r:p1rdt7089-p1rdt7089lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31cd4834-477f-4060-8efd-0504c8e8eaa9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73cfcce9-a925-4f29-9cde-6dd6f50735e1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73cfcce9-a925-4f29-9cde-6dd6f50735e1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "625b6c93-5baf-422e-bbe0-ac474e8c21b5", "name": "tr(r:p1rdt7090-p1rdt7090lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08d3a02a-555d-4ad1-9b13-d413b7a16eef"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d6a4c80-d261-4350-8224-8fe5191459c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d6a4c80-d261-4350-8224-8fe5191459c7"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c9e88619-7030-488f-8581-b184ead99804", "name": "tr(r:p1rdt7091-p1rdt7091lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6372a592-5e2d-41c8-819b-f56bfbb58e19"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0c42b48-7ca4-465f-b17c-048cb5f6d79b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "900a59fa-b9e1-4d82-96ad-d7a0e70edd73", "name": "tr(r:p1rdt7201-p1rdt7201lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f64ed4a2-6afb-447c-8c6b-15935e050a6d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6718b871-3967-4c29-83e5-441799c7fb92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6718b871-3967-4c29-83e5-441799c7fb92"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "ebdb125c-15f7-4ac7-8898-a0749c1a885a", "name": "tr(r:p1rdt7220-p1rdt7220lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a2f1a631-48f7-4291-9adb-588a66620ebf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d5e45d6-867a-4442-8258-2c04891dbc4b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d5e45d6-867a-4442-8258-2c04891dbc4b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "46e0dc9d-bf0c-4247-8399-4bba2bf59842", "name": "tr(r:p1rdt7224-p1rdt7224lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eeab7dfa-540c-4275-b159-f6ac4d1350f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d6a6156f-e72a-41f0-a307-e6030de24fde"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d6a6156f-e72a-41f0-a307-e6030de24fde"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c6728992-0569-4ad6-a2ee-a89c059a8cb9", "name": "tr(r:p1rdt7248-p1rdt7248lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a006c5f-e960-4ae2-a37f-d23d7b873a22"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2087cee5-9f6e-4400-8ca8-bbb120cd4dae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2087cee5-9f6e-4400-8ca8-bbb120cd4dae"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "c26eb6ec-9734-4824-8244-a225695d909b", "name": "tr(r:p1rdt7253-p1rdt7253lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f31b09da-e4cc-409e-9634-1907480039ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b4f7df4-5453-459d-8599-48fd5f29a9c6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b4f7df4-5453-459d-8599-48fd5f29a9c6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "13b3b35f-051e-4e07-9ad6-700afdf01778", "name": "tr(r:p1rdt7268-p1rdt7268lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a21680f1-33a7-44e1-9293-98c6861ba2a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1130272e-b98e-496f-aeb9-c094cf9cd824"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1130272e-b98e-496f-aeb9-c094cf9cd824"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "2bf5204f-ad9c-4982-ae22-74ef1aeca8c5", "name": "tr(r:p1rdt7298-p1rdt7298lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b658bf21-450c-4e6b-9dec-c5023a05fd19"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d304e5e0-2cc1-4167-9fad-6fc72228d828"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d304e5e0-2cc1-4167-9fad-6fc72228d828"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "8b3fc746-d9f0-45d0-ad16-d61574e7758f", "name": "tr(r:p1rdt7301-p1rdt7301lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84200441-4c26-4966-a4b7-6b91fb43f02e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43df4c14-a198-4d51-87f4-80000198cd47"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43df4c14-a198-4d51-87f4-80000198cd47"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f3cf9fd8-981a-45c4-8d3c-5f8be4e28074", "name": "tr(r:p1rdt7302-p1rdt7302lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a65c4d3-2fc6-48c8-b944-68c4229db3dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e2a141f-436a-45c0-9c15-179301a439c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e2a141f-436a-45c0-9c15-179301a439c8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "64a649e8-0397-468e-8602-656f8d0a2792", "name": "tr(r:p1rdt7306-p1rdt7306lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "607c7275-da9a-4620-b019-59a66e98c2e6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0926064a-1c87-450a-b282-23708de8aec4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0926064a-1c87-450a-b282-23708de8aec4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "0d51ff9e-3968-4c9c-b1a5-f15632d49f89", "name": "tr(r:p1rdt7307-p1rdt7307lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "231b5cf9-ec2c-47d1-aada-5454926561dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ce9dd2c-9e17-46b7-a6f4-e85077664432"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ce9dd2c-9e17-46b7-a6f4-e85077664432"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6a3a1abe-b81d-478b-9726-5826aada08d9", "name": "tr(r:p1rdt7311-p1rdt7311lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3a4dfb4-e1b3-43b9-ae42-b0cec47ff4ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2d6046b-9ece-4295-a180-41bf2ce47ce6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2d6046b-9ece-4295-a180-41bf2ce47ce6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9d5b01f2-1d26-4772-9ec5-58ed8abd8ee8", "name": "tr(r:p1rdt7313-p1rdt7313lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a3a5e1c-77a2-4a9d-89e0-7d1c94176787"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41e61263-feb6-4264-965a-fd1309d997a1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "34cd711d-2476-4079-bee1-db83e6e89155", "name": "tr(r:p1rdt7314-p1rdt7314lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0cf1844f-a32e-40f2-bc96-05fad3bdd88d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97844fdb-b016-4ca3-8777-b0553ead9297"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97844fdb-b016-4ca3-8777-b0553ead9297"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "92d3cf9e-563c-4377-b3aa-ebfc60ed645e", "name": "tr(r:p1rdt7318-p1rdt7318lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e86bc267-1607-4aa3-916f-ed826b0adfdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22b1ecce-d5df-4f42-abb2-9f4c3d3a28c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22b1ecce-d5df-4f42-abb2-9f4c3d3a28c5"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "0b6fafe7-545d-452c-b7f3-62b2c442f7dd", "name": "tr(r:p1rdt7550-p1rdt7550lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dead8520-e2f5-499b-9316-77780f9b1dfe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58be5cbe-5a7c-4fa5-972d-e03100b3bb46"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58be5cbe-5a7c-4fa5-972d-e03100b3bb46"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4fbe1b16-45a1-4f4f-b54c-4bd9dacab9b2", "name": "tr(r:p1rdt7551-p1rdt7551lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f0f3112-1395-48bf-88c1-8dd4b171478d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c4d7ee3-fc5d-4a17-a717-3d6b6d5a67ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c4d7ee3-fc5d-4a17-a717-3d6b6d5a67ae"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f6bb901b-e888-474e-937e-b47c34f55eec", "name": "tr(r:p1rdt7552-p1rdt7552lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db899c48-a801-4f83-b59d-e587ba80019d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f5d6708-cef4-4aac-9fa0-c738953c788f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f5d6708-cef4-4aac-9fa0-c738953c788f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9ef9d653-e17c-46b4-b8eb-308dcc2d2329", "name": "tr(r:p1rdt7553-p1rdt7553lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddf629eb-ea60-4fce-b731-7ebb33665829"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7a672b2-d127-4fb5-8cc4-8115b8ef3f60"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7a672b2-d127-4fb5-8cc4-8115b8ef3f60"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "1ad1e6cb-ac02-4298-94d9-b6e7b217363f", "name": "tr(r:p1rdt7554-p1rdt7554lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f6de990-0988-4126-86ca-d1fd72c555fe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86a6d184-d883-4e27-aee5-b89c82163284"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86a6d184-d883-4e27-aee5-b89c82163284"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "bd4532f5-197c-4d9d-88b6-69e85596cebd", "name": "tr(r:p1rdt7555-p1rdt7555lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0075333-98fe-4ee8-bb64-a18119b817c0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0de9c581-b78b-44d6-8693-59b995e2a3bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0de9c581-b78b-44d6-8693-59b995e2a3bb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6236b757-e2d7-4dc9-9418-64e399e056c9", "name": "tr(r:p1rdt7559-p1rdt7559lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f239ef4e-83f0-4a2c-ada3-8e30cef38472"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b593ec6-e1e3-48c2-b352-f7966f206aa9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b593ec6-e1e3-48c2-b352-f7966f206aa9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1d28deb4-7339-4686-a9aa-b3814787aab1", "name": "tr(r:p1rdt7561-p1rdt7561lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc6bd64f-1ad3-4bd9-b590-7d4b673a94b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05e30abd-3c40-4dbd-9261-ca8a8abd9c56"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05e30abd-3c40-4dbd-9261-ca8a8abd9c56"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "bb32295e-91d3-4b0d-a30b-f527438019eb", "name": "tr(r:p1rdt7564-p1rdt7564lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa33ca9e-e16d-4c49-8a70-c6c30cf7b038"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7588b3b-f54c-483d-b354-b9908483019a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7588b3b-f54c-483d-b354-b9908483019a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "38f3f4b0-05b8-469e-9bf4-9aa64b723b84", "name": "tr(r:p1rdt7570-p1rdt7570lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9b94106-b7c5-4ce9-9c19-053487848c2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2b3b9e1-3d98-44c1-bd38-9325623a1553"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2b3b9e1-3d98-44c1-bd38-9325623a1553"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c839a693-631e-43a1-943f-063d3e8cac8a", "name": "tr(r:p1rdt7572-p1rdt7572lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4307e78-304a-4175-8e81-9cb23d99f394"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69bf048e-54cd-4e41-a23e-485b0cd98fae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69bf048e-54cd-4e41-a23e-485b0cd98fae"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "14f1f8fd-687c-4967-a86b-790552e9bb2b", "name": "tr(r:p1rdt7574-p1rdt7574lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd487832-bc77-406f-a995-4b099fad7c64"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a742708-0f8b-42d0-a977-b5ce5e36a042"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a742708-0f8b-42d0-a977-b5ce5e36a042"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "40be45f1-06bb-4504-b1e8-03427c7e92c8", "name": "tr(r:p1rdt7576-p1rdt7576lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b28595b-dcbe-4d1b-92c4-94acf370bb1f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56b05024-7907-458d-a5c3-0e54ffbabdb5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56b05024-7907-458d-a5c3-0e54ffbabdb5"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a60ca7e5-fadd-4a55-9aaf-a6336c346d87", "name": "tr(r:p1rdt7579-p1rdt7579lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76f6a27f-0e4f-48b8-9dbd-31c6ffc4ec75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d00b7fe-0384-4c12-a0cf-8895458d3b80"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d00b7fe-0384-4c12-a0cf-8895458d3b80"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "dd238be0-3718-42e1-a1c0-47e911dee99f", "name": "tr(r:p1rdt7588-p1rdt7588lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f2dabc2-0b52-490c-b13a-32c268f6bd33"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abc940b0-c9f5-4582-adaf-ad7f4a79a35f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abc940b0-c9f5-4582-adaf-ad7f4a79a35f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "306bd8de-2bed-4392-b5cd-af1639de22f7", "name": "tr(r:p1rdt7589-p1rdt7589lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f9809eb-41e0-40a8-b43a-93556f767f68"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53e9cf92-1c91-428f-bdff-64257257ad5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53e9cf92-1c91-428f-bdff-64257257ad5b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "76c04b04-3f7a-4a92-8244-2b76e218fa05", "name": "tr(r:p1rdt7598-p1rdt7598lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f95e5fa5-a84c-42a4-b519-8d344e816ecd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff1e0d26-d845-43c3-9aaf-01d1c007b9a1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff1e0d26-d845-43c3-9aaf-01d1c007b9a1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b1a1407b-f572-4475-89dd-fdc7487a6303", "name": "tr(r:p1rdt7599-p1rdt7599lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a086b782-3a8d-44e9-9948-cb7f051219e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d838502-3769-4d70-839b-26fd628ce478"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d838502-3769-4d70-839b-26fd628ce478"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "be508024-b14e-4860-a815-fba0b7e63239", "name": "tr(r:p1rdt7605-p1rdt7605lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e36f1f1-6993-46b0-bafa-9530fd1652ef"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3488ff0-696f-4180-bc70-41ff37f9c365"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3488ff0-696f-4180-bc70-41ff37f9c365"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ab99af7f-f37b-440c-88b1-ff14dfa3d7c1", "name": "tr(r:p1rdt7612-p1rdt7612lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3410d88a-3e9c-427e-a79e-5c602455ed1d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fdfea70-187a-4bbc-ba3f-69cb74c4d5c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fdfea70-187a-4bbc-ba3f-69cb74c4d5c5"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "5633eb80-82db-48b3-b73b-40e06940ca5c", "name": "tr(r:p1rdt7615-p1rdt7615lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "105df8ff-ec38-4cd6-b557-c318b4023bd0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "269e9ba5-bc54-4cbd-9140-4b1bea74fc53"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "269e9ba5-bc54-4cbd-9140-4b1bea74fc53"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "20e0b0a7-7df7-4a70-90c4-c2e51e42f8d2", "name": "tr(r:p1rdt7616-p1rdt7616lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7167a2e-9e83-441e-a15b-0256848c3f6d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6af13868-ecb1-4110-be3f-537741287035"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6af13868-ecb1-4110-be3f-537741287035"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "ab1caeed-4f38-4dd1-8946-e1f37a4e07cf", "name": "tr(r:p1rdt7617-p1rdt7617lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01c9d31d-c3bb-4950-9bbd-00377c252ddc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4be4af94-fee7-40d6-9061-9a0fe0e7377e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4be4af94-fee7-40d6-9061-9a0fe0e7377e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "48f92b1a-dfcd-45a9-a9c8-46f9c5a3464f", "name": "tr(r:p1rdt7618-p1rdt7618lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0fef9b3-a4bd-421c-8a54-cbf6f44c460d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49f37435-54fc-42b4-baba-94f0611c8c76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49f37435-54fc-42b4-baba-94f0611c8c76"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9ba2159e-0ded-4752-ab15-e81614b1a3f6", "name": "tr(r:p1rdt7619-p1rdt7619lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "161d6f3b-8bd9-4fa8-9442-c6ff008e8d3d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a205379-48f9-444c-baf8-dc84fc9c6d8a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a205379-48f9-444c-baf8-dc84fc9c6d8a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ceab5e31-ac40-491f-8469-d2987e18c247", "name": "tr(r:p1rdt7620-p1rdt7620lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97be7ac3-a710-4de8-a666-276813582cd6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af91c50-929d-4ac6-9272-7c44d17a0094"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af91c50-929d-4ac6-9272-7c44d17a0094"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "bdcbb6b6-4e44-48e9-8d5b-4602c5816566", "name": "tr(r:p1rdt7621-p1rdt7621lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa48cf27-3b07-4460-ad9c-8d9862238645"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60f0bddf-6e4b-495c-a98d-f3940d69a5e9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60f0bddf-6e4b-495c-a98d-f3940d69a5e9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "654c6e8e-e5cc-4433-b8a9-4f1e0ff9afb9", "name": "tr(r:p1rdt7624-p1rdt7624lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e240270-762d-49f0-a4e4-29fcd6273ce5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e2075fb-9691-447e-9a73-f88649310bc1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e2075fb-9691-447e-9a73-f88649310bc1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "3e444053-e0f6-4c5e-b83a-778c710b6246", "name": "tr(r:p1rdt7625-p1rdt7625lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3e6cbe9-d1d3-4c59-981f-dad980f0999b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6b1e3b6-ce3a-4ad6-a046-6608530b2ec2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6b1e3b6-ce3a-4ad6-a046-6608530b2ec2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b3029529-3d87-4bf6-855d-9e4acc2459cb", "name": "tr(r:p1rdt7626-p1rdt7626lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56d67e3e-46af-4e2c-86a8-191d97b0ce8a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56f8eed1-77ae-4d65-80aa-7ae148350333"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56f8eed1-77ae-4d65-80aa-7ae148350333"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9123f9a8-9439-48d0-8966-b3c4d4d710e1", "name": "tr(r:p1rdt7627-p1rdt7627lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5bddd75e-1974-41ee-ab51-625c7485a573"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90d8891c-6e6d-46b9-8f88-acc9453c6541"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90d8891c-6e6d-46b9-8f88-acc9453c6541"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9afa56ce-eb98-472e-a5c6-91206e1a8521", "name": "tr(r:p1rdt7630-p1rdt7630lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "723e2b5c-414c-4f3d-ba23-d2df4bc63e75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ad2599f-313b-49c6-abaa-19177e1a9edc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ad2599f-313b-49c6-abaa-19177e1a9edc"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b9fc1aba-239f-4d0d-8085-2dd63d6da04b", "name": "tr(r:p1rdt7631-p1rdt7631lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9e53141-a773-4127-9558-3887070a8f36"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4861056b-b634-4900-94bb-d6c995387351"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4861056b-b634-4900-94bb-d6c995387351"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "752c4be4-3b4b-44b4-ae38-4efa162ae539", "name": "tr(r:p1rdt7632-p1rdt7632lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36e7cd28-6795-41d5-847d-92347871384f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7235cf3a-dd26-47f7-884c-6335024a3064"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "e911abc7-52f8-4093-a459-c3ca4018ece3", "name": "tr(r:p1rdt7699-p1rdt7699lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec849ee4-3d69-46a9-9a2a-242a3943e46c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bfa76dc8-4007-4e52-9692-2eec7cb574e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bfa76dc8-4007-4e52-9692-2eec7cb574e0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f4c59d36-a424-406c-abe0-7ec431462ff8", "name": "tr(r:p1rdt7701-p1rdt7701lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "74968ebc-53c5-4fc6-8172-3ffa9dea7683"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0cc95d09-c799-488e-81e8-50326a7da1ea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0cc95d09-c799-488e-81e8-50326a7da1ea"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "76f31e46-6028-4e28-9c78-d861c071c648", "name": "tr(r:p1rdt7704-p1rdt7704lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02ea9067-6a2a-48b6-b5f1-10992b9fbd77"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ef392d6-b408-4a7f-8a67-9fe43e1df582"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ef392d6-b408-4a7f-8a67-9fe43e1df582"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "aded564b-854a-4916-b3de-3ee4098f53f2", "name": "tr(r:p1rdt7712-p1rdt7712lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4462b9c6-748f-48e9-9ff9-7f20a06cf456"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59a62487-c709-428e-9e97-c7c285a1305c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59a62487-c709-428e-9e97-c7c285a1305c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ac1905ca-2d2b-4806-8ad1-5ac7cd2f4526", "name": "tr(r:p1rdt7718-p1rdt7718lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "048e2bab-67f2-4975-81a1-bbc9f2f9cd88"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6d10a4e-e7bc-4448-bca3-a5f2117b6198"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6d10a4e-e7bc-4448-bca3-a5f2117b6198"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a39660fd-d276-4af3-afe6-1cd2ff97fa07", "name": "tr(r:p1rdt7735-p1rdt7735lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62078787-3ae2-47b3-8f67-8e89e110c8be"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96dcd934-01a0-4719-89bc-a18430edf179"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96dcd934-01a0-4719-89bc-a18430edf179"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "ce2cab85-3bda-4e0e-9cbc-d2bea2fe03e1", "name": "tr(r:p1rdt7790-p1rdt7790lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97198258-8ba3-4950-8747-3241c6a4fcee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ed564b5-8d49-4ff7-94c2-b245981472e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ed564b5-8d49-4ff7-94c2-b245981472e8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c43106ec-5430-410d-a310-0f90dbe8b582", "name": "tr(r:p1rdt7954-p1rdt7954lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21e15d54-eab8-4204-9ed6-407fd8684700"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9dd5bb5-1410-4635-8a85-d23d7c3e55ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9dd5bb5-1410-4635-8a85-d23d7c3e55ad"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9cba1db2-bbe9-438b-a0ae-cbe9c6042c84", "name": "tr(r:p1rdt7973-p1rdt7973lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "016e4575-cd41-4993-be9b-5e5236a139ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3a96167-4b09-49c9-baf7-4fb588ecb002"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3a96167-4b09-49c9-baf7-4fb588ecb002"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "73995ff5-d40e-411d-80e1-03503328178f", "name": "tr(r:p1rdt7983-p1rdt7983lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e261b565-1f57-4cdc-bdd6-e045ee55d290"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb63be48-94ec-4c9f-9991-77892e14171b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb63be48-94ec-4c9f-9991-77892e14171b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "ee7e1b81-29bd-4324-bd7f-edb721cfe6d1", "name": "tr(r:p1rdt7986-p1rdt7986lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "93a5388e-ffd7-403e-b6cf-26b7e81feed1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "415fe6e9-953e-40f6-8ae8-43834e4e6ce4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "415fe6e9-953e-40f6-8ae8-43834e4e6ce4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "40ae26e7-8612-4ca1-af9a-6138c75b525a", "name": "tr(r:p1rdt7988-p1rdt7988lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48e4b67a-0a47-48f0-b787-0a639db89caa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94f12107-697c-4278-95e0-32b6eb49fdb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94f12107-697c-4278-95e0-32b6eb49fdb3"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "68d17fd2-4b36-4948-b180-d122e210a188", "name": "tr(r:p1rdt8012-p1rdt8012lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bfb33cd-0cf1-455d-81e7-3d0472fa1b41"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5b22c57-7912-4e9f-9b06-6a8ff706a58d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5b22c57-7912-4e9f-9b06-6a8ff706a58d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "4d09727b-7ad9-4895-b375-82bcd4bbeee8", "name": "tr(r:p1rdt8015-p1rdt8015lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc543f54-740b-4a7f-b1c5-eb3783a8ade0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6c5d7ff-cfcd-4b30-98db-eb44a95d6841"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6c5d7ff-cfcd-4b30-98db-eb44a95d6841"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9312b2f6-1773-4a40-bf4a-1a6db143517c", "name": "tr(r:p1rdt8034-p1rdt8034lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f83d22a-fa1e-4a4e-aab9-a9dea8ee06e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "972fe574-f88e-4a8d-8845-d5baa2f378a7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "972fe574-f88e-4a8d-8845-d5baa2f378a7"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "67d378fb-5a38-42c9-85a2-d6c5d30de182", "name": "tr(r:p1rdt8149-p1rdt8149lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b706c56-20f1-49ed-9cbe-0ec1491b83e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9951633b-4311-4ca2-9316-3801be13fe97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9951633b-4311-4ca2-9316-3801be13fe97"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b0592825-0ebc-47eb-b648-6b5e9eca65f6", "name": "tr(r:p1rdt8150-p1rdt8150lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78081763-07d2-4989-b492-e1c5178c4097"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cd1ae47-6aaa-4b57-ba44-1e74f6ea54b7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cd1ae47-6aaa-4b57-ba44-1e74f6ea54b7"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d471ae12-2ba6-4052-a460-048edfdc8258", "name": "tr(r:p1rdt8151-p1rdt8151lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c794942-d5ce-481f-9c6a-563a2180a4ba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a8deb5-b46b-4d4c-876c-b44b2258a6fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a8deb5-b46b-4d4c-876c-b44b2258a6fa"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "49759203-777f-49ae-b598-ca28caffe71e", "name": "tr(r:p1rdt8153-p1rdt8153lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b44d5021-4fdb-4618-bcb2-237ecf2e10e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a542ca5-b24e-44dc-8b68-c00aa024afad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a542ca5-b24e-44dc-8b68-c00aa024afad"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a7da70e8-efbf-4e0b-a7f7-eeb682445e70", "name": "tr(r:p1rdt8154-p1rdt8154lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42ab6054-1866-49c5-b2ab-3cf27199c1c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32fefbef-e10b-4758-8c2e-ccafad49aa5d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32fefbef-e10b-4758-8c2e-ccafad49aa5d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "cdab182b-63a8-43ed-a657-4a881f34363d", "name": "tr(r:p1rdt8155-p1rdt8155lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1613a53e-5194-4d26-b83b-475d9f02a32c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51812cd8-eec8-4862-8413-d25a7e9862dc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51812cd8-eec8-4862-8413-d25a7e9862dc"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "8e5d5e35-2a37-4ca3-b6d8-ac657a25cc53", "name": "tr(r:p1rdt8157-p1rdt8157lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a30e197-897f-4516-b4e5-f70081e6f8c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa6d4429-8a95-4ebd-9e3a-9867734245bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa6d4429-8a95-4ebd-9e3a-9867734245bd"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9c6e09ab-62cf-4cf2-ad4b-85f28da49b1b", "name": "tr(r:p1rdt8159-p1rdt8159lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42b9c576-ddba-4be1-bc64-a37d8cbdfa84"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1dd4660-3cd0-4709-b1ef-1c598e5e39fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1dd4660-3cd0-4709-b1ef-1c598e5e39fb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "4e23e836-b3c0-414d-8b6b-35675ebd0a0a", "name": "tr(r:p1rdt8160-p1rdt8160lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38b72c12-2e2f-4d83-8f5a-9d8503dc29eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "232fed6b-fe0f-4a44-93e9-e6675b50c39c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "232fed6b-fe0f-4a44-93e9-e6675b50c39c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "36e7363c-1995-4a3a-86c5-a0ace2ea4bd8", "name": "tr(r:p1rdt8161-p1rdt8161lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25946c74-15c2-412c-baed-8de5f7aecf98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac7e489e-7249-4702-9ed6-131cad34500f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac7e489e-7249-4702-9ed6-131cad34500f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "ce00bda5-ef31-4200-abe8-7edb6e2ce469", "name": "tr(r:p1rdt8346-p1rdt8346lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14b429c3-41da-4123-b661-40cbdfaf33e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9560197a-21d1-4601-8bcb-213df4844f4a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9560197a-21d1-4601-8bcb-213df4844f4a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "e76e538a-44eb-4381-8e37-7fb09b2f63a2", "name": "tr(r:p1rdt8405-p1rdt8405lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60829dab-c129-4017-961a-81435d8afa93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "408d5d7b-fc71-46bb-8de0-2d4e628c29b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "408d5d7b-fc71-46bb-8de0-2d4e628c29b6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d7e934e2-03f8-4a6a-ab5d-ad3b3dd48470", "name": "tr(r:p1rdt8408-p1rdt8408lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28af960e-6f27-483a-8029-0c5f1641f51d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3fe0f77-a7c1-48e3-94aa-30b69f20ca65"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3fe0f77-a7c1-48e3-94aa-30b69f20ca65"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "95aaee68-75c3-4a09-afe8-2ae7e6764680", "name": "tr(r:p1rdt8414-p1rdt8414lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b48f78d-1092-4536-bfb3-029da6a70dff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fca92353-c013-4c41-8507-ec8704410834"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fca92353-c013-4c41-8507-ec8704410834"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "2a2e6bf5-cdb1-4881-a7ba-b0751befd246", "name": "tr(r:p1rdt8422-p1rdt8422lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ce65512-7d5f-4514-b55c-1775e80dd94d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfe35c35-8164-4825-81e3-10a2ece2cb27"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfe35c35-8164-4825-81e3-10a2ece2cb27"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "704a77eb-97a5-44a1-ab78-f3e5768a865c", "name": "tr(r:p1rdt8434-p1rdt8434lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f28de397-0db4-486a-8ce6-9f65c68703b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdc5ef2a-c0d0-4702-b6c6-df08af1e8746"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdc5ef2a-c0d0-4702-b6c6-df08af1e8746"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1ccbc567-041b-40ab-b2c1-6da64ae2a300", "name": "tr(r:p1rdt8436-p1rdt8436lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fcc42825-2690-4965-a99b-e78285a9b84e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b24c9345-625f-499d-96cf-30b2de5839b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b24c9345-625f-499d-96cf-30b2de5839b6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "db06099d-51cd-4922-8556-5fc046213ce9", "name": "tr(r:p1rdt8439-p1rdt8439lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07f340ca-58c2-4331-8265-a39a45c87b75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a38f544-e250-4fc9-942c-946c5cde0a33"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a38f544-e250-4fc9-942c-946c5cde0a33"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c1cf0331-e671-4257-a481-22857029dcff", "name": "tr(r:p1rdt8440-p1rdt8440lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bbfe31b1-38ce-4ae4-9143-bf08c81617e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "049362b4-49de-4e80-921e-ff763aaab2d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "049362b4-49de-4e80-921e-ff763aaab2d1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "bb01e69d-d66e-4622-a9d2-49439101442f", "name": "tr(r:p1rdt8441-p1rdt8441lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b423745-cc70-4c3a-adb0-f648170b4ab1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72c8f08a-0ba5-413e-a805-f9436b41ff29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72c8f08a-0ba5-413e-a805-f9436b41ff29"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d9636448-6ac3-4dab-b534-39f3b2189242", "name": "tr(r:p1rdt8442-p1rdt8442lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6700763-e6dc-4626-ac2b-22985f0043be"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b5ae28a-95f8-4023-aa23-36809fe96b10"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b5ae28a-95f8-4023-aa23-36809fe96b10"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "f401dbb6-1c00-4683-a97f-240f0d404ec0", "name": "tr(r:p1rdt8444-p1rdt8444lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "685fbdbf-47af-4cc2-97ce-354dd04ce915"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "978920e8-edf9-4bee-85f9-45f4081ed0ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "978920e8-edf9-4bee-85f9-45f4081ed0ca"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "e78e59b0-1628-44f3-9f40-434870c7485b", "name": "tr(r:p1rdt8445-p1rdt8445lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc0ee90f-1f9e-435e-bac4-86a4688c48fc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e0923da-550b-479f-b3d8-3e0320db6701"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e0923da-550b-479f-b3d8-3e0320db6701"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ba075575-7d34-4581-bd89-580a7809f865", "name": "tr(r:p1rdt8447-p1rdt8447lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13b8cfc1-d8eb-4f47-b024-c1daacf3771d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5dbc3459-6a17-4075-899a-6aab16fb3ab7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5dbc3459-6a17-4075-899a-6aab16fb3ab7"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "68fa5476-e1d3-4fcb-aae1-82554760837b", "name": "tr(r:p1rdt8450-p1rdt8450lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "184f95d4-cde1-4bf1-8a74-ebc7097cb10e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b4216c8-9e99-446c-ad09-5a09f046dd59"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b4216c8-9e99-446c-ad09-5a09f046dd59"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "832c98de-e0df-4a23-a77c-8bae8f9c82a2", "name": "tr(r:p1rdt8456-p1rdt8456lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0089e5ea-d706-4a74-812f-654ae73eabcf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d094b779-ebcc-4837-9ccb-31808e2a544b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d094b779-ebcc-4837-9ccb-31808e2a544b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f1be4587-95df-49ac-b27e-27bf9042374d", "name": "tr(r:p1rdt8458-p1rdt8458lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "433162b1-2a9b-4187-ba28-ec57503d76f6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e597d8da-e876-44a5-a109-1ce84527c557"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e597d8da-e876-44a5-a109-1ce84527c557"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1be9aa15-7b2b-40a1-9e35-67939a2032bf", "name": "tr(r:p1rdt8470-p1rdt8470lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "442de065-9e2a-4ff8-9100-1298d3fe0f6f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "edb15d92-f98a-4fa2-8129-ad8a39e0dc0c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "edb15d92-f98a-4fa2-8129-ad8a39e0dc0c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "978ee383-d478-4f12-a155-7192f5c3a6c6", "name": "tr(r:p1rdt8490-p1rdt8490lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37c41a4b-e439-42a1-b9a7-0582c528f0e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a84e1424-7faf-4077-9461-b39460f10ef0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a84e1424-7faf-4077-9461-b39460f10ef0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "eb250ab0-b078-4fd6-890a-38d97425c873", "name": "tr(r:p1rdt8492-p1rdt8492lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "307d9c6d-d5ee-4490-95d3-5a9b1d171e54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "127e4cc7-6413-4482-9ec3-40f8bde02d0c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "127e4cc7-6413-4482-9ec3-40f8bde02d0c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "325e4fe1-dddd-4f95-bd62-a4992948ea11", "name": "tr(r:p1rdt8802-p1rdt8802lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26ccaeff-3a34-4835-8906-1145148549c6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95a1a7c7-6055-47c9-a742-c1b81f6c7478"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95a1a7c7-6055-47c9-a742-c1b81f6c7478"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "7e8bf118-8d3d-438f-8fad-151a16e1fcba", "name": "tr(r:p1rdt8805-p1rdt8805lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3444af6b-f9d4-4229-b6b2-2114300c3f94"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "715c92fa-2470-4869-8d5f-0b4f3f8360d4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "715c92fa-2470-4869-8d5f-0b4f3f8360d4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "32c72906-a147-498a-a113-be950d59104f", "name": "tr(r:p1rdt8898-p1rdt8898lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d887dbc-43bd-413e-8e72-5c95a2ed0be8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6ff626c-d2fc-4b97-9013-4fd544d946a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6ff626c-d2fc-4b97-9013-4fd544d946a2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "ef3714fd-edab-4865-a2ad-4ee8d9fde607", "name": "tr(r:p1rdt8901-p1rdt8901lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f23ab51c-56f3-4421-b66e-7cdcf109787d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d53c0a2-78cc-4988-85a4-884ef039f5fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d53c0a2-78cc-4988-85a4-884ef039f5fa"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "955c5326-6c66-4d62-bf37-292638de7f37", "name": "tr(r:p1rdt8902-p1rdt8902lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f44ec9b-338a-4ae1-a26b-26422f218c13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d1c8eb9-7f79-49ad-9e93-6c7cdcc95e22"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "1ee50b0d-7af3-4a06-b0ea-4bc31090e03c", "name": "tr(r:p1rdt8904-p1rdt8904lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2edd17c2-6dfb-4f86-8998-b90a99755e96"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e111e213-bcbe-42c4-b6ab-2c734ff5341c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e111e213-bcbe-42c4-b6ab-2c734ff5341c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "90046b1e-ffaf-44e0-87b3-cb95655e8345", "name": "tr(r:p1rdt8905-p1rdt8905lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "924fc042-6ddc-484b-b09f-c65b35817d25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2777cc-f3fd-491f-a10b-4ed381cb948d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2777cc-f3fd-491f-a10b-4ed381cb948d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "eec52181-4f73-420b-8698-07ba3d2a5ba4", "name": "tr(r:p1rdt8911-p1rdt8911lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26613f51-86bf-4ae1-86c0-f23e48cf606e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c306f79a-0240-465e-a486-d0f11614fc57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c306f79a-0240-465e-a486-d0f11614fc57"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "63095410-c01a-4602-bc80-e104ffc07c8f", "name": "tr(r:p1rdt8915-p1rdt8915lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "361385c6-bb6d-4bbc-ab7d-4a5774e03d82"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2fbbca23-6473-4344-ac2e-cc97078b3d8d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2fbbca23-6473-4344-ac2e-cc97078b3d8d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "40e3269c-7a28-4e20-9fa3-df93e3a99468", "name": "tr(r:p1rdt8916-p1rdt8916lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "adcc33f8-72a3-434c-a021-6c5973713a91"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d268e33-708d-4bae-8348-cad27fd0d81a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d268e33-708d-4bae-8348-cad27fd0d81a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "e40cccd7-b398-4341-a909-7d8cef79eb67", "name": "tr(r:p1rdt9075-p1rdt9075lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "907828f5-8e26-41c4-8fbc-a3744608181a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6752e8f4-9e37-476d-aec2-4a2fe7c1e2dc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6752e8f4-9e37-476d-aec2-4a2fe7c1e2dc"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "adc3a07a-82a2-4e00-a6c8-1099bb4e0b40", "name": "tr(r:p1rdt9076-p1rdt9076lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2ce5116-c4f0-4ac7-a34f-3ba44c99d04b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdd64386-e256-47f8-8cef-1c933f993a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdd64386-e256-47f8-8cef-1c933f993a29"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "8f50d2c0-fc10-4b59-b588-c78fee9366a5", "name": "tr(r:p1rdt9077-p1rdt9077lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b7f2f09-976a-45da-8186-229aeedeb689"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b83eaaa-a092-42ca-a746-db4d9658d62b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b83eaaa-a092-42ca-a746-db4d9658d62b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "7ecefea9-516a-4cb1-8c06-cac3a09bcc5e"}}}}, {"uuid": "557e8429-9e93-4160-bcc4-3af879a36ea8", "name": "tr(r:p1rdt9084-p1rdt9084lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4251587d-600f-40a0-9aec-229fb2e3f2df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f0e4f59-8a46-4abf-9f06-e0383a59a45d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f0e4f59-8a46-4abf-9f06-e0383a59a45d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "eec76648-0280-4fe0-af8d-9f996d84c74a", "name": "tr(r:p1rdt9085-p1rdt9085lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7fcdf409-885c-4c95-834e-988842ed3f5c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "565bbfb1-a28f-4db2-be48-cbd58972025a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "565bbfb1-a28f-4db2-be48-cbd58972025a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "b66392de-bea5-4d55-91a6-d82ab4d1b213", "name": "tr(r:p1rdt9089-p1rdt9089lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b4ec275-bea8-45f2-94cb-5e24e82179d8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8108ac8-2807-4a40-85c2-db21efaadadb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8108ac8-2807-4a40-85c2-db21efaadadb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "ed549b0d-f520-47b7-a35d-6cd2a3169d35", "name": "tr(r:p1rdt9090-p1rdt9090lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52c72b52-1c6c-46f6-adbe-1054eb233c20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fc84159-09b1-4ca9-9a7a-a4fecab19f83"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fc84159-09b1-4ca9-9a7a-a4fecab19f83"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "dd3d2dc6-ddf3-4f3b-80f3-cdfaa7eee7d2", "name": "tr(r:p1rdt9091-p1rdt9091lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "563c6bb3-d8ed-4fce-ad66-3892426248df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e93ea18-150d-4d80-bac7-f3e1b87c5b4e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e93ea18-150d-4d80-bac7-f3e1b87c5b4e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "fe126484-9dac-44a4-b9a7-d0b95131a9d9", "name": "tr(r:p1rdt9093-p1rdt9093lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c29179f3-0b4e-449c-8562-a8fcb675be6c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f0726b7-3050-4c78-9c06-b9fd0c863ff3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f0726b7-3050-4c78-9c06-b9fd0c863ff3"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "658d959f-56a4-46f3-9c64-ca76eaf73c1e", "name": "tr(r:p1rdt9264-p1rdt9264lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bdf3994-bb0c-44f4-b1ea-ab29e73bd39c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c01a9b2-b002-4279-905e-950452f64f32"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c01a9b2-b002-4279-905e-950452f64f32"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a17c260a-bae1-4173-8fee-fc9ea0a4b0f0", "name": "tr(r:p1rdt9265-p1rdt9265lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b336e76f-17f3-4f5d-ba84-f24c3a4e3eed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "77d62813-61d3-4afd-9f21-869e2ea23e17"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "77d62813-61d3-4afd-9f21-869e2ea23e17"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "c682f3a2-335b-4876-b3f3-f17e582fb5fb", "name": "tr(r:p1rdt9266-p1rdt9266lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fbb2bd0-d109-4248-85f3-266fe479677f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78278589-be2d-4d99-9c03-92c221348917"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78278589-be2d-4d99-9c03-92c221348917"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4d59ae8b-6777-434b-8467-62a8e2a3f6f4", "name": "tr(r:p1rdt9298-p1rdt9298lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61ba1001-8b9d-481c-b205-45c6e0beadc1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "208f222c-45db-445f-ba0b-a4a195ca68a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "208f222c-45db-445f-ba0b-a4a195ca68a6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "bf58b1a3-eb94-4a84-8bf6-222f3696dfcb", "name": "tr(r:p1rdt9302-p1rdt9302lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4a41fe9-62ce-45ba-abcd-086ba429baa0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180fad26-0e7d-4e2c-ba17-c8e3315ca278"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180fad26-0e7d-4e2c-ba17-c8e3315ca278"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "3276927a-5d0f-4e74-818b-d91b6f65ebdd", "name": "tr(r:p1rdt9310-p1rdt9310lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3035d22c-c39f-4f07-9fe9-29888b16057d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4940a0e-dcc2-45fb-baa9-aadc84f8e882"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4940a0e-dcc2-45fb-baa9-aadc84f8e882"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "daf94052-bd8a-473d-8d00-900a40a66ce6", "name": "tr(r:p1rdt9311-p1rdt9311lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7011f1dc-1e7d-4961-9a23-620b7f5737af"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9e0aa7d-9097-4370-8f5e-52a5885da85c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9e0aa7d-9097-4370-8f5e-52a5885da85c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "31a8d47b-fb37-4710-af26-3c40bd619792", "name": "tr(r:p1rdt9312-p1rdt9312lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8721684-5439-482c-b8e5-be330d3cf745"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a21f5ca-51ef-4f81-8229-163182f011cf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a21f5ca-51ef-4f81-8229-163182f011cf"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b6d6629c-ebae-47e9-826d-42a5addc585d", "name": "tr(r:p1rdt9314-p1rdt9314lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d25f8d60-8aa7-4975-96dc-eba7696fa8ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3df13d91-365e-411b-917d-b28df5989280"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3df13d91-365e-411b-917d-b28df5989280"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "3f1254d8-6ad4-49ed-91f4-40f1125f1d3c", "name": "tr(r:p1rdt9316-p1rdt9316lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "644c5887-31f1-436c-bbf6-dae5a70743a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c97a99f-545b-49cd-b1fe-4fd9e04bf37f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c97a99f-545b-49cd-b1fe-4fd9e04bf37f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "26117ef4-73d0-4826-814c-c5b074c7979d", "name": "tr(r:p1rdt9333-p1rdt9333lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0da91bf8-b687-47df-a7dc-41e6166fd667"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a68a1c01-a04c-4af6-b1c8-02ddd1d67e0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a68a1c01-a04c-4af6-b1c8-02ddd1d67e0b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "a951a707-992b-4291-83f8-194955fad7e9", "name": "tr(r:p1rdt9377-p1rdt9377lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61972a50-ce24-4ec1-8535-402665b55a55"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e98299cb-8bad-49ea-8627-f3cfe01b9e23"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e98299cb-8bad-49ea-8627-f3cfe01b9e23"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9d097eb6-0536-4329-9e47-689931548ec9", "name": "tr(r:p1rdt9381-p1rdt9381lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5791345-57dc-4f54-ab54-ea63e6a54ee0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e37f182-5a60-470d-8f5b-ba145cc27973"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e37f182-5a60-470d-8f5b-ba145cc27973"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "bb2e720c-aead-4e23-990b-b5d38b5fc81c", "name": "tr(r:p1rdt9384-p1rdt9384lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6eb9c7a5-5ab1-4d9b-a59e-538b68ad0bb9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abd09ea6-221c-47d9-beec-1062e0dd4aa7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abd09ea6-221c-47d9-beec-1062e0dd4aa7"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "35b8a83c-ef5a-4306-832c-66fbeafd2d4a", "name": "tr(r:p1rdt9396-p1rdt9396lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a597011-5e60-46fe-90d6-85728ff0ffa3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc7e0a25-d6d6-4b07-b3dc-4fe5646915e2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc7e0a25-d6d6-4b07-b3dc-4fe5646915e2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d3d8a817-bbdd-4e5c-a3e4-0432297353b5", "name": "tr(r:p1rdt9413-p1rdt9413lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f750e531-5ade-40a9-9bb0-042220ce9807"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8180ee90-a46e-4d85-9742-d47b24f5e169"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8180ee90-a46e-4d85-9742-d47b24f5e169"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f57739f9-f91a-47bd-ab2b-41bc22a489c3", "name": "tr(r:p1rdt9463-p1rdt9463lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "271ab023-4425-40d8-8080-2481c71309b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a015abb-ec63-4b31-9314-283b8499646e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a015abb-ec63-4b31-9314-283b8499646e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "85d043cd-32d6-4018-a524-c982b2241a28", "name": "tr(r:p1rdt9468-p1rdt9468lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b5695dd-714e-4de1-a63a-f142ff0460e1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4dbe1628-cd17-4f37-af2b-dd752c290fa4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4dbe1628-cd17-4f37-af2b-dd752c290fa4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "631e9419-1b56-46f4-baa0-837e133891b1", "name": "tr(r:p1rdt9469-p1rdt9469lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3fd32c7-2866-4699-93a8-dd3a9997d349"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09613257-d4cb-4c50-b35a-8aefc637c0c9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09613257-d4cb-4c50-b35a-8aefc637c0c9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "de8ccb6c-d747-4480-b079-fd149cfb48d4", "name": "tr(r:p1rdt9470-p1rdt9470lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acf91e46-ba32-44c3-a829-14c80a693d7d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1ab8727-2758-4513-8a7d-e02381faf1e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1ab8727-2758-4513-8a7d-e02381faf1e4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "abf8851d-3ebe-42f7-aaba-d53fec8ddcfb", "name": "tr(r:p1rdt9473-p1rdt9473lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4d8bafa-711d-4fd7-8374-7eeaeb43edcd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c14c3211-a0d5-464f-820c-cab04764d907"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c14c3211-a0d5-464f-820c-cab04764d907"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4a2ad2ab-089f-4dac-a5a0-897f492a374c", "name": "tr(r:p1rdt9479-p1rdt9479lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b006c3-79f8-4a27-b76a-d1b458ff2a21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6a8f268-6a5a-4b23-bd91-53c6b031442a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6a8f268-6a5a-4b23-bd91-53c6b031442a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1a93d30f-d1a4-4015-8c87-b38dda765cb8", "name": "tr(r:p1rdt16638-p1rdt16638lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c0d417e-c787-4b0a-a39e-b19ef274b36b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac361065-6b3c-4ac6-96d5-9b474eb3b80f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac361065-6b3c-4ac6-96d5-9b474eb3b80f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "25afcea6-d24a-41da-92e4-6285c2cd8d94", "name": "tr(r:p1rdt16725-p1rdt16725lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2d0eb0b-bbb6-4b3e-bdc6-4c8a0e7d466f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bae9a352-584d-4cf0-9ebd-eb280b684e78"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bae9a352-584d-4cf0-9ebd-eb280b684e78"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f5a6c76a-0ecf-4a13-89aa-362ecadefd29", "name": "tr(r:p1rdt28-p1rdt28lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e71eb2d5-cd10-498d-b9eb-ae337b2f8af6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b3c997d-cd47-439c-aeb9-326e12c2b869"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b3c997d-cd47-439c-aeb9-326e12c2b869"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "86f8773c-114a-4b4c-b9e3-f2717953ca11", "name": "tr(r:p1rdt29-p1rdt29lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b238dc5-7d8e-4b2d-8449-4dc212d7d227"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61fc3980-6aa4-415c-91c1-10d32c7c359c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61fc3980-6aa4-415c-91c1-10d32c7c359c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c02272a2-6a29-4dc3-bc03-1478a851798d", "name": "tr(r:p1rdt30-p1rdt30lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fa95a19-0e0a-49b3-bb86-7103fbaa4110"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d2be3b5-dbfc-4099-af9a-96368e60fe23"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d2be3b5-dbfc-4099-af9a-96368e60fe23"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "3426e057-9462-4775-84b0-7991d0317028", "name": "tr(r:p1rdt31-p1rdt31lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7c543753-fa26-41df-b7a6-3664395c0d45"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3510eedd-535c-4e58-b81e-c5ec09030479"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3510eedd-535c-4e58-b81e-c5ec09030479"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "06dad8ed-fa0c-4bfc-835f-beac3577743f", "name": "tr(r:p1rdt32-p1rdt32lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "834e959c-8ee6-4fff-b1fc-54c20fc0f20b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e374d6d6-1e75-4808-b65a-c7033e1bd528"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e374d6d6-1e75-4808-b65a-c7033e1bd528"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4d7dca1d-26ad-41f4-ae1b-09c3150c2ff2", "name": "tr(r:p1rdt33-p1rdt33lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f55e4012-a11d-4883-baac-9c013aff6058"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "065c8583-45e5-466c-b4c0-1c66bf970abe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "065c8583-45e5-466c-b4c0-1c66bf970abe"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "07af1c2e-7068-4f93-89df-8790c6dfe1c5", "name": "tr(r:p1rdt34-p1rdt34lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a9c4411-f402-464c-ad25-d439b87ef768"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "553a6868-acec-4492-a52d-5aa08414c612"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "553a6868-acec-4492-a52d-5aa08414c612"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "045e1e63-2c81-46df-aaf1-4d47299340da", "name": "tr(r:p1rdt35-p1rdt35lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "edc22f66-e919-448e-b990-76033c281d43"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f98cc066-fca3-4489-9770-047caee3e742"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f98cc066-fca3-4489-9770-047caee3e742"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "686d21ca-2738-4df6-85e2-c888af76c985", "name": "tr(r:p1rdt36-p1rdt36lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8dcdfef-b40e-4f1c-9b7c-e84846f68c5a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a4fb658-c3ba-428a-82bf-b38ae68dd908"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a4fb658-c3ba-428a-82bf-b38ae68dd908"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c5b237cb-07a9-4965-9cd9-3e14350dcdea", "name": "tr(r:p1rdt37-p1rdt37lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dcbfdc3-b597-4e9e-a86f-4d0ff396ba70"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90a16370-67f7-4abd-992c-990d1eb8f17e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90a16370-67f7-4abd-992c-990d1eb8f17e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "da3f8abb-ffb8-4aea-ab9c-4af9437c8824", "name": "tr(r:p1rdt38-p1rdt38lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b45513a3-8e88-45e9-99d3-6d244c90c256"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "752aca33-7682-4e8c-a8b1-624467e02958"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "752aca33-7682-4e8c-a8b1-624467e02958"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f893bdea-9004-4473-94ab-1c3988f9d1b5", "name": "tr(r:p1rdt39-p1rdt39lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a01c83d1-4adb-4b2a-8de3-441d7c1dd054"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "623ec6b4-cb70-4437-9d79-5ec577bc3199"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "623ec6b4-cb70-4437-9d79-5ec577bc3199"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a4e4a009-9d22-4aa9-9fcc-1b5aa8981612", "name": "tr(r:p1rdt40-p1rdt40lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "577124ac-ea2b-4a60-be47-14b0f5db305e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d08444c-79a3-4ba0-8c69-1855a600dea0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d08444c-79a3-4ba0-8c69-1855a600dea0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1fc2c7da-303e-48e2-b221-3ef3ba1d67ec", "name": "tr(r:p1rdt41-p1rdt41lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5b5b3ae-f657-4fd4-a311-ab1dbe9d749e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "793d0bf4-4d9f-4df4-bc95-d528dd7d31d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "793d0bf4-4d9f-4df4-bc95-d528dd7d31d5"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "80968e2c-9233-46d1-bc47-325532bf9287", "name": "tr(r:p1rdt42-p1rdt42lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a778171c-22a1-4320-9e3c-43888d734e34"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8fb27dc9-b404-49d1-84dd-0cde418b037d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8fb27dc9-b404-49d1-84dd-0cde418b037d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "68f7ceff-6b60-422e-bd73-d4d1a0f6e584", "name": "tr(r:p1rdt43-p1rdt43lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7728581d-66fc-4e7e-b2b0-85fa02c90523"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "274aa0ec-f229-454c-b52d-23130bacb97e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "274aa0ec-f229-454c-b52d-23130bacb97e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "8a76055a-3d2f-4462-98c5-e1f8ff4d0cb5", "name": "tr(r:p1rdt44-p1rdt44lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d9ee2ff-e2bc-4d76-b173-5ba5cc48c9b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c813f8a2-226b-431d-a41a-195cf5e8b01a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c813f8a2-226b-431d-a41a-195cf5e8b01a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "16131cf6-271d-4626-98a8-fbae6ee38baf", "name": "tr(r:p1rdt45-p1rdt45lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29a79372-9c75-4a9c-81df-a7491b87e58a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e276abc-bb27-47e4-9de8-adaccbf964dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e276abc-bb27-47e4-9de8-adaccbf964dd"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "76a4d98e-68c5-49bf-910b-f3f35032d52f", "name": "tr(r:p1rdt46-p1rdt46lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05082892-d69e-4c8f-ba19-c2a627e1c345"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aacdcb46-43e3-4147-ac25-3a9c1223e13a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aacdcb46-43e3-4147-ac25-3a9c1223e13a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f0cbaba9-64ec-4d25-8744-ef1281846908", "name": "tr(r:p1rdt47-p1rdt47lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ea0531d-530c-4088-86a1-3de96a8938ea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f031530a-b3fc-4f8e-b0ac-139009d1256c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f031530a-b3fc-4f8e-b0ac-139009d1256c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b0be705e-8c18-4891-b919-bb25a7238d83", "name": "tr(r:p1rdt48-p1rdt48lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1667a8c6-aeb4-4f22-97b8-62ffefcc12a4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f1790fe-a399-46e3-b9e3-5979837777ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f1790fe-a399-46e3-b9e3-5979837777ce"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b0e0d3ff-8ba6-472a-a5eb-d28c6ce44f6c", "name": "tr(r:p1rdt49-p1rdt49lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "137c345c-77cc-4324-bc0e-e0ba896a5f43"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e5bcc7e-f35c-4bbf-a7ff-a82817488b11"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e5bcc7e-f35c-4bbf-a7ff-a82817488b11"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "26b88ccb-02b0-4122-b422-897c4c26a389", "name": "tr(r:p1rdt50-p1rdt50lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c5d8237-0351-4eb2-83e6-13975b37bfa7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8208c617-caa9-46a5-b28a-8a5b0d9898a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8208c617-caa9-46a5-b28a-8a5b0d9898a2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "cc35b6a6-16d4-488e-97ec-7b14db0fa4c0", "name": "tr(r:p1rdt51-p1rdt51lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f5cef5c-bcaf-4cd9-afbb-a18bd14dfcd4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09d7f030-a9b4-4705-82af-6cf140ba64d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09d7f030-a9b4-4705-82af-6cf140ba64d1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "0e0c6d92-cc6e-448f-a29c-1e3178238ad3", "name": "tr(r:p1rdt52-p1rdt52lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6fb1323-f697-4423-a70d-838056200402"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c70a7331-8c41-4370-b053-3eae432d52ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c70a7331-8c41-4370-b053-3eae432d52ae"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "5050b907-1a62-46d6-82b0-89342148ec87", "name": "tr(r:p1rdt53-p1rdt53lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7305e2b-0a48-4630-8b8e-c3819f1c9cd1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2536a0eb-a35c-40d4-9773-b78379e7481a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2536a0eb-a35c-40d4-9773-b78379e7481a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "28ce3059-1ead-42c2-bdee-4daff71b5662", "name": "tr(r:p1rdt54-p1rdt54lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a898f4c-f522-4e69-be4a-e935e339e011"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57889d14-4aac-4aee-a9e2-677a047e8054"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57889d14-4aac-4aee-a9e2-677a047e8054"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a7a2f704-cd96-459a-b12e-4435494a6582", "name": "tr(r:p1rdt56-p1rdt56lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1d8f5898-7d36-4e40-9980-76d11ef18adb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85ad3bf0-7e82-4e32-8106-faddcf725bdf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85ad3bf0-7e82-4e32-8106-faddcf725bdf"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "0c05cc28-0486-48b9-95ba-0b91bb9b6203", "name": "tr(r:p1rdt58-p1rdt58lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a4ccf80-2611-4089-9353-439809aa7854"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3367c40-9f47-42d9-b627-bc502b170f2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3367c40-9f47-42d9-b627-bc502b170f2a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ffc7aa30-29d5-4db5-aab5-dd84d3d0772b", "name": "tr(r:p1rdt59-p1rdt59lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ea7e0bb-bdc5-429a-8889-2f12c94db72e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8aca9934-9439-4ce6-9ee3-475980324054"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8aca9934-9439-4ce6-9ee3-475980324054"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1696924f-e157-42db-86ef-900c1b1cf8bb", "name": "tr(r:p1rdt60-p1rdt60lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d99e903-3536-4a73-b0d5-ca11f5af6e32"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2517cea-05d3-4b7f-b9fc-0df0fde81235"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2517cea-05d3-4b7f-b9fc-0df0fde81235"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "89ed6c2c-a1ba-4a20-8835-2c08c61547b5", "name": "tr(r:p1rdt61-p1rdt61lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "744725a8-af2a-47cf-948f-9d453a932e32"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70f11a44-826f-45b8-9dc3-0f51ce6c9733"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70f11a44-826f-45b8-9dc3-0f51ce6c9733"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "08edc741-554e-4ef1-bd93-218dc727e5ef", "name": "tr(r:p1rdt63-p1rdt63lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab2b6727-4d87-4b00-bd49-ba7a6b1b9ce6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fac6d4e1-b14d-4973-9626-6a4bde2d2a42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fac6d4e1-b14d-4973-9626-6a4bde2d2a42"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "5ad5756b-21d2-45ca-a385-c7e2b2f1bb99", "name": "tr(r:p1rdt65-p1rdt65lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9397c58-45a1-4ec3-bd84-b4cd5b52dc80"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ae9cb89-7cb8-48c6-a5bc-4178ee364ae8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ae9cb89-7cb8-48c6-a5bc-4178ee364ae8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "72eed041-134e-4a31-a0d0-02a861b323f4", "name": "tr(r:p1rdt66-p1rdt66lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99615f32-0614-4c23-a1e1-b3e8e5688cce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfb9fa3b-c758-4c2e-bc51-f297b1ed21bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfb9fa3b-c758-4c2e-bc51-f297b1ed21bf"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f8d59a4d-dfb6-49b3-83c6-0454d6bfd414", "name": "tr(r:p1rdt68-p1rdt68lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb9e5f0f-8bcf-4019-a786-3f24334e9ae7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd2d6296-a302-4027-9e5f-c24a56a1a1ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd2d6296-a302-4027-9e5f-c24a56a1a1ac"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "5e8def15-b1ef-4d36-afe9-0db73af1d8f4", "name": "tr(r:p1rdt69-p1rdt69lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9396562e-4f87-4e04-b248-502b851fe19e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7057debb-bd4d-4156-a253-0f3a14cdd784"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7057debb-bd4d-4156-a253-0f3a14cdd784"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "00e0932e-3680-4ecb-a35f-b8f379416748", "name": "tr(r:p1rdt70-p1rdt70lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50f3b5f3-3fb5-4fb9-b2e6-b37200af0901"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02440066-bc62-4629-96c5-4b497827de5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02440066-bc62-4629-96c5-4b497827de5b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "aec13c01-30e8-4332-b54a-8dac2e56eb19", "name": "tr(r:p1rdt71-p1rdt71lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bcea1fd6-3c51-48af-8528-d3d7bc8e4f01"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e71f106d-4b41-405f-bce9-3d06b336a554"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e71f106d-4b41-405f-bce9-3d06b336a554"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1f2db932-2776-43d2-b812-944ba379f05d", "name": "tr(r:p1rdt72-p1rdt72lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2faff95d-f394-427a-9d62-75224f830c9e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b59eeab-d997-4186-ab59-0424644d5aeb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b59eeab-d997-4186-ab59-0424644d5aeb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a54d9c9c-facb-438a-9923-8a3535cb078c", "name": "tr(r:p1rdt73-p1rdt73lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc531967-1a7b-4424-83ee-e1131c6fd94c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f027d15-df82-4989-93e5-a3b40c862b08"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f027d15-df82-4989-93e5-a3b40c862b08"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "e5380797-1d80-4e0a-945e-4762a3c8c342", "name": "tr(r:p1rdt74-p1rdt74lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b884fef-8b8f-4ed5-9033-b8177d1c7d70"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37880102-8a9c-4f7b-930a-b29a94241866"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37880102-8a9c-4f7b-930a-b29a94241866"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ea369155-ad0d-4a7c-a74b-c12c8e2ecdea", "name": "tr(r:p1rdt75-p1rdt75lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "510ea93c-7dd1-4fa3-ba3f-6c362856c7c1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "699bbf24-59ba-4dba-8bd4-1cf04a7e6e47"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "699bbf24-59ba-4dba-8bd4-1cf04a7e6e47"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "147887b1-2e3e-4a7e-b06c-a473fb5f6bab", "name": "tr(r:p1rdt76-p1rdt76lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfbb212a-9882-4468-86ac-578c93fde1d8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ecf2223-f120-45b4-8aab-a36d60161aec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ecf2223-f120-45b4-8aab-a36d60161aec"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "86c622f6-2403-4cab-95f8-aff9389bf18a", "name": "tr(r:p1rdt77-p1rdt77lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31b06630-2aae-4fe7-9e31-f911c91121cd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3fd9bf7-ecdd-4dcb-966a-f426d5f2ee81"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3fd9bf7-ecdd-4dcb-966a-f426d5f2ee81"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4a5f4547-b555-41df-9f08-d6c0903360f2", "name": "tr(r:p1rdt78-p1rdt78lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36bfd1f1-80ca-4b7d-a68b-9aa77ceff96e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f0255b7-5369-40eb-8814-959b0d4245b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f0255b7-5369-40eb-8814-959b0d4245b6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ecc7b1e7-8a00-4c32-93e5-f1f981ed361a", "name": "tr(r:p1rdt79-p1rdt79lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b32c9763-ddff-435b-a28c-8f65111c6cb2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "624d03d5-ac53-4d58-ac86-62834fa13c61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "624d03d5-ac53-4d58-ac86-62834fa13c61"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "da68cb40-2f31-4750-a2b6-b091f4654833", "name": "tr(r:p1rdt80-p1rdt80lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b03f8e29-a5b2-4bed-b68c-219276674b6a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ce05c72-facf-447f-ba14-cc2ef64579a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ce05c72-facf-447f-ba14-cc2ef64579a8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "87aeed9d-f5cd-4e6f-810f-c6099cb337fb", "name": "tr(r:p1rdt81-p1rdt81lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "063e25be-2abb-49ae-b459-ddd08ba93bb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b610625-09e3-4b72-a8fe-b0c36f5e137c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b610625-09e3-4b72-a8fe-b0c36f5e137c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "83fcf4f2-0d36-4f7a-b36f-b4151a82bc3c", "name": "tr(r:p1rdt82-p1rdt82lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7627cbc6-c54a-432b-8cba-59e448f6d45a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9872669f-fd85-458a-8951-ec12965fb42b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9872669f-fd85-458a-8951-ec12965fb42b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a617b3b6-59a8-4e36-a4ea-11874a9cd427", "name": "tr(r:p1rdt83-p1rdt83lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aa0b7c2-9d55-4faf-8778-76a6f23bcf3e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8dac1e07-5eb6-4945-a3d9-95b77310358d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8dac1e07-5eb6-4945-a3d9-95b77310358d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d41dfd2f-d99a-4bd0-910f-036f4aebe455", "name": "tr(r:p1rdt84-p1rdt84lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e9f4b13-5fb5-46b2-9258-83582d47d61a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdb8aaf1-0e21-42e0-a72d-666646561235"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdb8aaf1-0e21-42e0-a72d-666646561235"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "26f6d003-75a7-4f8c-b229-262ff28235a3", "name": "tr(r:p1rdt85-p1rdt85lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fc415bc-f457-4e9f-bbd4-783a71b67ad6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40f4034e-c735-419b-80cd-d729d75f4692"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40f4034e-c735-419b-80cd-d729d75f4692"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "110f66e7-2818-450b-a67e-5acde54125dc", "name": "tr(r:p1rdt89-p1rdt89lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac4ad276-90cb-48c0-bfd0-1f2aa0233ce2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "468963dd-428d-4810-a28c-1904bc06fa64", "name": "tr(r:p1rdt150-p1rdt150lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12451cbc-eb14-4814-b274-12eb2241c78a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d156fdde-5620-4a6f-b8c1-a3ab986fcc88"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d156fdde-5620-4a6f-b8c1-a3ab986fcc88"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "4ffdedbd-6f86-4c39-ba6a-51dbb16741b8", "name": "tr(r:p1rdt177-p1rdt177lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ad84ef4-4dcc-42f7-99ed-b8d21cebc465"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d64d858-a9f7-430f-890e-a456f8913c30"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d64d858-a9f7-430f-890e-a456f8913c30"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6d4ef4b9-6445-45ff-9620-36a122a1de83", "name": "tr(r:p1rdt178-p1rdt178lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6912a245-ac1c-4ddd-b021-3bc35cbbe2c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3314fa8-a838-4028-abb5-043425fd0785"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3314fa8-a838-4028-abb5-043425fd0785"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "38f32bd3-69bf-4ea6-b2fd-ec94b21cce20", "name": "tr(r:p1rdt180-p1rdt180lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5258d4de-be4c-478d-b752-7f4efb0af0a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3e633bc-311e-4698-a413-9c6cf09c42a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3e633bc-311e-4698-a413-9c6cf09c42a8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "16bc9340-852f-45b4-8c50-5aafae060aaf", "name": "tr(r:p1rdt181-p1rdt181lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79d0fee6-369b-4f95-a2d2-cd05232652e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05401825-91f8-41f8-9204-ab5806458594"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05401825-91f8-41f8-9204-ab5806458594"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "fd2bbd2d-e55a-4574-9301-aa415ede0134", "name": "tr(r:p1rdt182-p1rdt182lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08e378d4-4ca6-4c9e-93fa-36ff87a3cf0f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db407ddd-fb81-4767-99e1-9aeab12fc770"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db407ddd-fb81-4767-99e1-9aeab12fc770"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "8cfbd069-d0c7-45ae-a317-62a2b705c48e", "name": "tr(r:p1rdt209-p1rdt209lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcb27aab-e828-41a6-ad98-d197897a1a69"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4724ea16-dc31-48f8-98b8-b9a223e9a4bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4724ea16-dc31-48f8-98b8-b9a223e9a4bb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "12ffe536-6060-4f3e-907b-af4d833feb8b", "name": "tr(r:p1rdt210-p1rdt210lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d782d5e-3960-415c-9e33-6742777a5a0a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05f6a3bf-d465-4f16-8205-616d1f4dd465"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05f6a3bf-d465-4f16-8205-616d1f4dd465"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "938e5105-62c4-4dab-b455-5ac4f54fcb4d", "name": "tr(r:p1rdt211-p1rdt211lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9401940-26a4-40f3-9b9a-5231a5c4e171"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1d5af6ce-9a4c-414a-bbd8-15d82f50cb57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1d5af6ce-9a4c-414a-bbd8-15d82f50cb57"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "91a80b45-db0d-4e91-b5a9-5fb6548e00dc", "name": "tr(r:p1rdt233-p1rdt233lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f5ed5d5-93fc-4f3c-a78b-df7019863b67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "591461d4-20da-4165-a210-4dbaedd81016"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "591461d4-20da-4165-a210-4dbaedd81016"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "228841e9-58e9-49e3-804f-445cc0619ab5", "name": "tr(r:p1rdt234-p1rdt234lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80331f15-8b31-454c-a289-49cb79923252"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e480f304-b192-4107-91e1-131d481657b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e480f304-b192-4107-91e1-131d481657b2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "40659e90-bb60-4c4f-a678-ce45935e490f", "name": "tr(r:p1rdt235-p1rdt235lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14b85850-d83e-4a5e-83c3-ccb485bb85aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d8a6708a-d098-4e02-aac6-4aba7fdc71a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d8a6708a-d098-4e02-aac6-4aba7fdc71a5"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a5c0e877-4159-4080-9098-05bf7f634c74", "name": "tr(r:p1rdt236-p1rdt236lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "190d6c51-94b6-462e-8fee-cce57f1ab66d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7dd709e3-c5ec-4a01-8297-11f4d1261c3a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7dd709e3-c5ec-4a01-8297-11f4d1261c3a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "7769b43e-a233-4400-b584-7a9f35d5a83e", "name": "tr(r:p1rdt237-p1rdt237lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8c8b8f8-7a41-4d16-b509-2d7c7af9509d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b72726f3-250c-4d98-86bc-5120137bd0f1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b72726f3-250c-4d98-86bc-5120137bd0f1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "7d4d8011-cd32-41e0-bdbf-c7f5d31224e2", "name": "tr(r:p1rdt251-p1rdt251lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b801037a-e1bb-4c5c-8d18-ed285c8c1d3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42dff28c-89e7-4b56-bf23-3dcdd3ca216f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42dff28c-89e7-4b56-bf23-3dcdd3ca216f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "0f9e6d0b-d35a-481b-b931-182fab18aed5", "name": "tr(r:p1rdt252-p1rdt252lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69b2ee46-ab5f-48c8-a26b-170ed2b57fcb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5fd6466-e740-4f06-a842-798195d62154"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "72716a86-0835-4f9b-8e47-9a6051a19336", "name": "tr(r:p1rdt253-p1rdt253lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1a85646-be2b-4b15-9c2f-cc603c7e06df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "704fece3-3b83-4c0b-bcd1-d463b3cdaf6b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "704fece3-3b83-4c0b-bcd1-d463b3cdaf6b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d1c72dc1-3fc7-4da6-9a5d-72909f222914", "name": "tr(r:p1rdt254-p1rdt254lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ab802e3-3a0a-413c-8865-e3b3d08e44a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "655d8f44-aa2f-4548-a1ca-83fcce9fa7aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "655d8f44-aa2f-4548-a1ca-83fcce9fa7aa"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "bf18b63e-79ca-428f-a8b3-d5a935d41cbd", "name": "tr(r:p1rdt257-p1rdt257lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fb307f7-3690-4931-999a-4daab4d8c9e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4c28500-44f7-47c6-b8a8-d1e3468494e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4c28500-44f7-47c6-b8a8-d1e3468494e3"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "96da8edc-0a10-48ed-bb7d-3658fda97e9f", "name": "tr(r:p1rdt258-p1rdt258lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e28087b-b80e-4043-b0f0-0bc82c91f5e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad9ffaef-f21b-43da-9f67-3a8271edb6bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad9ffaef-f21b-43da-9f67-3a8271edb6bd"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c3a4c349-43bd-4f33-98fa-ccf7e44ca6f5", "name": "tr(r:p1rdt259-p1rdt259lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33a0a070-9cce-4a82-bd22-24a65f02ef97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6a0feb3-78c1-4d69-8d18-2a8c3abdcf54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6a0feb3-78c1-4d69-8d18-2a8c3abdcf54"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ecbce8a2-3f89-4fa2-a55a-3bd07a3ac13f", "name": "tr(r:p1rdt260-p1rdt260lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba0ef4a3-43ba-469b-8ce8-ca7a5a984071"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d8d796d8-6750-4ca5-ae07-1b07331ce6ee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d8d796d8-6750-4ca5-ae07-1b07331ce6ee"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6d2548c2-862a-4a2f-b2c3-1d8870d42a76", "name": "tr(r:p1rdt261-p1rdt261lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "209cebda-044a-42a3-b2f0-fe5b76b80643"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fe4ec5b6-61fb-4b66-9e43-19d81af88966"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fe4ec5b6-61fb-4b66-9e43-19d81af88966"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4bd983f3-706d-4920-a462-e4bf12558318", "name": "tr(r:p1rdt262-p1rdt262lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf660777-f77e-4d9b-afff-73a84274c270"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30952601-1479-4770-9b77-9fe3465310b7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30952601-1479-4770-9b77-9fe3465310b7"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "034163b4-1e88-4baa-a811-5fbd58057562", "name": "tr(r:p1rdt263-p1rdt263lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e26e5dc-8c98-4fcd-b125-3265eb00f3f2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c7501f4-0394-4766-a3c5-b17fda7f3817"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c7501f4-0394-4766-a3c5-b17fda7f3817"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "559841a4-f8e4-4cdd-b1c6-04b11c6d09dc", "name": "tr(r:p1rdt270-p1rdt270lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7eca59ac-01f1-40d7-a0ec-51f355285e01"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d33a03d6-fddc-4e47-8018-cd7d290b30b0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d33a03d6-fddc-4e47-8018-cd7d290b30b0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c6c81cef-c3ee-431b-a3ab-6ad7205c02a8", "name": "tr(r:p1rdt275-p1rdt275lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d4e6a87-0313-419f-8feb-7ea3a29f59ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6715c6a-6869-412a-8e59-e5c2eb03c56b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6715c6a-6869-412a-8e59-e5c2eb03c56b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6bb22125-784e-40ef-bbc5-22745e6216db", "name": "tr(r:p1rdt276-p1rdt276lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "186ffdfe-2346-4218-bd6b-b813ea6b3b62"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b478b4f8-8d5e-47b0-a56a-8b991dc8d944"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b478b4f8-8d5e-47b0-a56a-8b991dc8d944"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ae187547-57ce-46fc-9314-8dda6c95cd4f", "name": "tr(r:p1rdt277-p1rdt277lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "add5e39f-f02e-4a61-a156-d5721cec25d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24486e15-ff1e-45b3-aa02-703263f04844"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24486e15-ff1e-45b3-aa02-703263f04844"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4676c5fd-19ba-4329-a862-9e9801bd00a8", "name": "tr(r:p1rdt278-p1rdt278lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b89bfea1-97cd-41f7-af59-9602a3fc6c06"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8af5824-d5d7-4cba-98b7-d72993909f22"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8af5824-d5d7-4cba-98b7-d72993909f22"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d0bfd334-fcc6-47b4-bfc1-72eb7bb1598c", "name": "tr(r:p1rdt279-p1rdt279lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "153bb615-5ee5-4eec-bcf7-94ea0098aeb6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bf679fe-712f-4db6-9df9-debb29b7ee73"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bf679fe-712f-4db6-9df9-debb29b7ee73"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "da111543-380a-4eb1-88b8-031590d01eda", "name": "tr(r:p1rdt280-p1rdt280lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9cb7919-b8bd-46c1-a173-90a5d241c46e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e4eafd2-0f68-4e2a-a62c-89cb877004d4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e4eafd2-0f68-4e2a-a62c-89cb877004d4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "655bfadd-98d9-4039-821c-21dbe9549447", "name": "tr(r:p1rdt281-p1rdt281lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac745c6f-6e78-4a68-affa-649f91d3aa7c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e01a56d-1bfc-4169-9c3e-1373f9dbeb38"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e01a56d-1bfc-4169-9c3e-1373f9dbeb38"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "015e49ce-e6a5-4944-aaf3-b61823a75f58", "name": "tr(r:p1rdt297-p1rdt297lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d32493ec-06be-48ef-959e-779c79c507a3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a8430e1-656f-4fe2-a11b-00adf429d75d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a8430e1-656f-4fe2-a11b-00adf429d75d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d68d8140-dff3-41be-a497-53455f71c1f6", "name": "tr(r:p1rdt298-p1rdt298lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a468f13-c61f-4c01-aa27-c75fb02030e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33e93250-9c11-4650-9469-412129855857"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33e93250-9c11-4650-9469-412129855857"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b887118e-e038-4a64-9fa7-6038d52ec663", "name": "tr(r:p1rdt303-p1rdt303lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9672c49b-8316-4907-b204-7505483210b0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6353ab92-f66f-47d8-97ac-058cf030ff82"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6353ab92-f66f-47d8-97ac-058cf030ff82"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "5d8d8e70-8ce0-42db-a87f-175f615651be", "name": "tr(r:p1rdt304-p1rdt304lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c51ccb17-eed6-4ce0-b839-e7b26001fe3e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a22ac71-bf3a-4016-86ce-fb25f471be5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a22ac71-bf3a-4016-86ce-fb25f471be5b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "0f017bf0-d183-4c7b-80ed-7c974ee6f0bd", "name": "tr(r:p1rdt305-p1rdt305lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b936973-54dc-41e7-a413-8932c31f0793"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90948977-fe1a-43b3-a8a4-86c080ae4906"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90948977-fe1a-43b3-a8a4-86c080ae4906"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "d74936db-efae-41d6-84f2-34c53eef6e48", "name": "tr(r:p1rdt306-p1rdt306lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57a78c71-e5a8-4dfd-8359-e368b7b198fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53eba878-66fa-4d30-8af4-1f583abe5f16"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53eba878-66fa-4d30-8af4-1f583abe5f16"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b13ff87f-aca0-42a0-a97e-45cfc6179f01", "name": "tr(r:p1rdt335-p1rdt335lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b07c4a6-39a7-4521-bce7-3f1ca0ff4a66"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8e448ea-e66d-4e16-80c0-8e742d7cac55"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8e448ea-e66d-4e16-80c0-8e742d7cac55"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1b3a45a4-d129-4c3f-8eb1-9066ad24ac9c", "name": "tr(r:p1rdt374-p1rdt374lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d425a00d-c0e9-465d-9d9b-af4d64708fba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35993388-185f-4d1d-9dcb-16eb7556728f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35993388-185f-4d1d-9dcb-16eb7556728f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "0c577442-ca1d-4668-b313-e9fbb1e29ad8", "name": "tr(r:p1rdt376-p1rdt376lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f2a0358-b10d-4b62-8f8d-9a5054fae87d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d354e81e-b007-4bbe-b1db-50d7afacd0e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d354e81e-b007-4bbe-b1db-50d7afacd0e0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "de6b39ba-8c53-4f20-8506-bd2983c7866c", "name": "tr(r:p1rdt383-p1rdt383lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d49257c8-f8eb-4024-9c02-461d18cdd3d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8569c197-174f-46ef-96c2-e0c674d7b046"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8569c197-174f-46ef-96c2-e0c674d7b046"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b775f5a3-abc7-439d-8cc2-1dfdb80e9ee2", "name": "tr(r:p1rdt384-p1rdt384lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7adf2f4b-f0fd-4c53-abcf-d90fe1a2b4c4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c56b4839-f007-4c9b-93a7-9147399f983f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c56b4839-f007-4c9b-93a7-9147399f983f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "dfb875e0-909c-48e0-a0f3-c240ef90cdec", "name": "tr(r:p1rdt385-p1rdt385lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91f76b91-e00a-4a88-8ee8-ec403c2c7d96"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "579c3e97-d1dc-4306-91e6-4cbbed29f882"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "579c3e97-d1dc-4306-91e6-4cbbed29f882"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "fb2a2471-54f3-48e3-9ee1-13f4e72e499a", "name": "tr(r:p1rdt414-p1rdt414lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3034e62-dd19-4ecb-bb39-6d0566e3a2ef"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29a78735-964b-4381-bea0-01e5b1b79be9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29a78735-964b-4381-bea0-01e5b1b79be9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "860da100-ad3e-4792-8a28-931f8187fdf3", "name": "tr(r:p1rdt415-p1rdt415lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "101c6236-a474-45c8-b065-f5fa045b1107"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "789d55de-619d-43cd-b056-ebe1be4c2dea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "789d55de-619d-43cd-b056-ebe1be4c2dea"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "feeba731-1ea5-4dc1-9a62-c0e1d7795eea", "name": "tr(r:p1rdt416-p1rdt416lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d16d5f5e-a376-4e39-a845-d2cde8800da3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473f5822-3412-4f3d-836e-f62314efa5b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473f5822-3412-4f3d-836e-f62314efa5b2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "47414dae-3422-48b1-bdca-7b83009a888f", "name": "tr(r:p1rdt417-p1rdt417lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "71fa675e-bc20-46f7-b6f1-c88962f9f3cb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98bb09be-6506-49e8-8fd8-1a01d6861162"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98bb09be-6506-49e8-8fd8-1a01d6861162"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b0547079-9b1b-44dc-ab7c-c29dfea00990", "name": "tr(r:p1rdt418-p1rdt418lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16b7f1e9-3405-4c5f-96c7-d5c08d791907"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e189aaf-7650-49b4-83dd-94a29111aca2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e189aaf-7650-49b4-83dd-94a29111aca2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "469de0ef-7a25-4acd-9205-a71329a39894", "name": "tr(r:p1rdt419-p1rdt419lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81cfd2a2-295c-4b73-abba-05ffee810523"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d9603d6-5e5e-4cc0-aa86-1bdb80f7e1cf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d9603d6-5e5e-4cc0-aa86-1bdb80f7e1cf"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "47093818-356c-43f7-a773-06ced59d5483", "name": "tr(r:p1rdt420-p1rdt420lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4cf05060-0a39-49a9-a761-79fb136e2965"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51673983-9230-421b-8501-bf71601b1b13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51673983-9230-421b-8501-bf71601b1b13"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d972da8f-8281-4cb3-ba18-4eb86c2e9897", "name": "tr(r:p1rdt438-p1rdt438lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10620dcc-049c-4417-b4ac-922a56c0d4a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41f19802-32ca-4afc-8418-fe93e3ced1bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41f19802-32ca-4afc-8418-fe93e3ced1bb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1e703d7c-207c-41bd-8432-62623e3294cd", "name": "tr(r:p1rdt445-p1rdt445lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11571d26-573f-49f7-99fd-828dde97afd8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc7e7e51-f849-4bf4-b720-462daeb21932"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc7e7e51-f849-4bf4-b720-462daeb21932"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4ef117e0-3533-4ed5-a707-27b8b79018e0", "name": "tr(r:p1rdt446-p1rdt446lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3dfe357-889d-42e0-a59a-821c9f843456"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0727e1f5-f2ca-4e19-9dc3-89e185002e52"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0727e1f5-f2ca-4e19-9dc3-89e185002e52"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "31791e27-69b5-46d6-8de1-580b87fb30a0", "name": "tr(r:p1rdt452-p1rdt452lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d51e6f65-c45c-4f10-a17f-6ef684a0a06c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44f86829-17fc-4e83-b2a5-705454293161"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44f86829-17fc-4e83-b2a5-705454293161"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "dea578b9-0003-4140-837c-70a58205dfbf", "name": "tr(r:p1rdt453-p1rdt453lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1bb6f93-7aed-47d7-99db-7c17352a42b8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d58e1471-844f-46ef-9d9a-43753b1dee25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d58e1471-844f-46ef-9d9a-43753b1dee25"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "de71a091-0216-4333-98f4-8e2ee12f7aa3", "name": "tr(r:p1rdt454-p1rdt454lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "82459f47-0c6f-4173-8c35-5a9fe5db9713"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b3e7941-9bdd-48f9-a4a5-a553da9bbb57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b3e7941-9bdd-48f9-a4a5-a553da9bbb57"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "7146b2ad-9e2f-4f11-a4a5-d9ea6e8d1f02", "name": "tr(r:p1rdt455-p1rdt455lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "183de04a-a665-4112-a912-1df68b61d164"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53b40b3c-db5a-4fa0-bedb-f293c6eac473"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53b40b3c-db5a-4fa0-bedb-f293c6eac473"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c7fedd72-fdc1-4ce2-9c76-ae0aa80d0095", "name": "tr(r:p1rdt456-p1rdt456lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf205ba7-ac66-4318-aeca-c75eb96cbd1e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6abe982-a205-4607-bacf-08e9d7cb6f54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6abe982-a205-4607-bacf-08e9d7cb6f54"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "780c1284-1c66-4d72-92d1-cf26850a20c2", "name": "tr(r:p1rdt457-p1rdt457lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12fef7fc-57f0-4494-becd-4724b84dbbcb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "866745cc-62c9-429f-8389-fcc5a1710f17"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "866745cc-62c9-429f-8389-fcc5a1710f17"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "226ddf12-0560-4cd0-a652-b078040e8853", "name": "tr(r:p1rdt458-p1rdt458lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b61caefd-d5aa-4019-9ac0-aaf8cedc71d0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67e071ab-e3dc-4779-9e81-585547cd22ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67e071ab-e3dc-4779-9e81-585547cd22ca"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "50a65c14-ae69-47d6-ae06-21a2674632d0", "name": "tr(r:p1rdt459-p1rdt459lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12d5c579-0570-44db-a751-8eeb92355af9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9eb57d99-ae80-43da-b0cb-b26bdd583e1a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9eb57d99-ae80-43da-b0cb-b26bdd583e1a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "93fa4f7d-bc58-4a12-a440-e0c490ea7b13", "name": "tr(r:p1rdt460-p1rdt460lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59b616e5-76b8-406c-843f-5c71398af81b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028bc055-0ee6-4729-8cd2-15bd7153f975"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028bc055-0ee6-4729-8cd2-15bd7153f975"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "1f7a885d-21ca-439d-8116-826789387357", "name": "tr(r:p1rdt461-p1rdt461lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc35f44e-d8d9-41d0-b014-caa3d8d7a91e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd9a4931-435b-4b48-907c-024c0b8a4816"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd9a4931-435b-4b48-907c-024c0b8a4816"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f12f78be-1ac8-4e86-98fe-de6b0683fa21", "name": "tr(r:p1rdt462-p1rdt462lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fcfdc5bf-1c87-42e2-8b35-1f7125d3b5ed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d96f458-607c-4820-90b1-6fb2625ace7f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d96f458-607c-4820-90b1-6fb2625ace7f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "b7ade355-2af9-4a38-a2d7-80f3335d2f0c", "name": "tr(r:p1rdt463-p1rdt463lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7637cfdb-6a14-4313-95d4-e25beba178f3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f660c35e-85f8-4f0e-b03b-806006c76c67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f660c35e-85f8-4f0e-b03b-806006c76c67"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6148cbd4-2f8c-491c-9c54-ff853b4687d9", "name": "tr(r:p1rdt464-p1rdt464lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a634585d-0c70-428e-a3b2-1ec4717d7878"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "749e07aa-74ce-40f2-a352-9c55f9914377"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "749e07aa-74ce-40f2-a352-9c55f9914377"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "70d8c332-07fd-46c0-a5a7-a6324f5ec5bb", "name": "tr(r:p1rdt465-p1rdt465lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a94f7afe-e8b0-4b24-8196-6b05e98c3830"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "433b0872-49c4-452c-941c-8083a72840ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "433b0872-49c4-452c-941c-8083a72840ce"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "780d3254-dfcd-415b-afdf-f9fdb2cce1dd", "name": "tr(r:p1rdt466-p1rdt466lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b20fa59a-8573-461a-9c4a-0d47e40d2601"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f422478c-0d77-48c8-87fb-e883d945f8a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f422478c-0d77-48c8-87fb-e883d945f8a6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "31fd8d26-743e-4351-a4ae-a932c424b517", "name": "tr(r:p1rdt467-p1rdt467lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ae86125-88c3-44fb-9fe9-1a5d820606f6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23ed76af-dcb2-4333-ae4c-d7439a37cf87"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23ed76af-dcb2-4333-ae4c-d7439a37cf87"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4b987818-3fb4-41f5-b55b-d2cfb74befcd", "name": "tr(r:p1rdt468-p1rdt468lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a180b972-cf0e-4a2e-9bcf-a0ad90bb3d83"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b368fb8f-7f4d-4558-b6b2-2e1db4087727"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b368fb8f-7f4d-4558-b6b2-2e1db4087727"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "18968b56-3a29-41e6-8cbd-8e4fe75001da", "name": "tr(r:p1rdt469-p1rdt469lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48179f57-b0b9-491b-b654-81583768923a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d12ab15f-746d-462b-b395-e2b330ba1226"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d12ab15f-746d-462b-b395-e2b330ba1226"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "bac74da6-006a-4067-88ac-cf7b2ae508c5", "name": "tr(r:p1rdt470-p1rdt470lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86178159-ccd7-45a3-b711-ac237321d52a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15ab2647-a801-4cb5-a1f7-528118ff5dea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15ab2647-a801-4cb5-a1f7-528118ff5dea"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "58fdf097-af18-4b81-9503-d9f13735bc26", "name": "tr(r:p1rdt471-p1rdt471lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eed7e6a8-2b4a-4a54-b69a-e3e1a0614213"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40d98c0b-4c66-4581-9553-f5f57c4b27b9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40d98c0b-4c66-4581-9553-f5f57c4b27b9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "346f5458-a006-49fe-9e5e-9c356990a6a0", "name": "tr(r:p1rdt472-p1rdt472lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fa14b51-a977-4e40-8f9c-28249e576fcf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f026a1d3-23b0-4454-a09b-e1c08cc06392"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f026a1d3-23b0-4454-a09b-e1c08cc06392"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b8909095-2209-43a8-8464-b209838a828c", "name": "tr(r:p1rdt473-p1rdt473lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76880999-6f79-4fc6-9367-1c419eee26d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f435ec5-8c03-45ba-925b-83bad9501047"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f435ec5-8c03-45ba-925b-83bad9501047"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "dc6f4797-c71e-4d15-b933-feb4df8752ec", "name": "tr(r:p1rdt474-p1rdt474lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d709af4b-1115-403b-a68d-76c63c93adf2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "839858f4-3b18-40c3-86f3-e27225e6aba4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "839858f4-3b18-40c3-86f3-e27225e6aba4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "7ecefea9-516a-4cb1-8c06-cac3a09bcc5e"}}}}, {"uuid": "a492d8ab-a787-43c8-8be0-cab66a7fe3ed", "name": "tr(r:p1rdt475-p1rdt475lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c39140c6-8892-480a-81b9-738c67ed1591"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1be3e20a-3890-4e9c-b568-ca99421e751c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1be3e20a-3890-4e9c-b568-ca99421e751c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6c7260e3-92c6-44cf-9183-fc804409b3d6", "name": "tr(r:p1rdt476-p1rdt476lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5421facb-0713-404c-97e9-56669fc762b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ffde8c6-9dba-4f13-bda5-a0edf17c736d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ffde8c6-9dba-4f13-bda5-a0edf17c736d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "d82f544d-1e58-46b4-9ecf-d4338fbccc82", "name": "tr(r:p1rdt477-p1rdt477lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d1eb09d-dff4-4fa3-b96f-ef59b63d6128"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7c94703b-303a-4713-95c0-b2933fe0e70b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7c94703b-303a-4713-95c0-b2933fe0e70b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d4ce0825-6ee4-4ec0-b8e1-1563e762a41a", "name": "tr(r:p1rdt478-p1rdt478lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eba354c-f4bf-4c49-a8ad-998ab9489e5a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c93c776d-68b8-4e4e-8e5e-d5e34003473c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c93c776d-68b8-4e4e-8e5e-d5e34003473c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "50c07068-48a1-4f26-a8f9-e98aa62f0fdd", "name": "tr(r:p1rdt479-p1rdt479lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85acd1fb-6da3-432a-9508-855ca991641b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8037b713-d948-43c9-8370-fb8fcf6dec15"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8037b713-d948-43c9-8370-fb8fcf6dec15"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d06c50e8-54b3-4baf-9665-3fab274a9a46", "name": "tr(r:p1rdt480-p1rdt480lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e5c3d02-1cd2-45e4-90d3-10b135c65f13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "423402f9-4160-481b-9951-a955f8314075"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "423402f9-4160-481b-9951-a955f8314075"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "733cc0fd-6a39-4cd5-981f-4aa1b1b62549", "name": "tr(r:p1rdt481-p1rdt481lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cf3136f-6dbe-4ed7-b9cb-e9f73b191f76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1761b021-00e0-4880-9f05-62cf67aef0e6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1761b021-00e0-4880-9f05-62cf67aef0e6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "148864d6-cab0-456d-8328-a75ad9b03ce3", "name": "tr(r:p1rdt482-p1rdt482lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10c2463d-8563-4737-aa7d-e1195c0af9f6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c445ea76-5167-4d55-b0c5-cc53dadc5b5e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c445ea76-5167-4d55-b0c5-cc53dadc5b5e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "16ca4d3d-9bed-4e6b-9ece-eb18548033ae", "name": "tr(r:p1rdt483-p1rdt483lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69b5d686-dae0-44c5-a261-f1a73bcb168e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "475b6a50-9814-4016-bb88-be5b1b2ac31d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "475b6a50-9814-4016-bb88-be5b1b2ac31d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "ab0dffc8-6dfa-406d-b78d-386b299b2e2a", "name": "tr(r:p1rdt484-p1rdt484lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b57b8e2b-62c2-49a0-801d-02cab8092ebd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f396745a-5edb-4ab8-8bc7-2b181719cbf4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f396745a-5edb-4ab8-8bc7-2b181719cbf4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "2bc14fe0-06d7-4d06-b082-4fa14b69d913", "name": "tr(r:p1rdt485-p1rdt485lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "445f61a4-8045-4558-a3c1-bb44336737ec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da38ec0a-f37d-4a5c-8da0-93410a8fb475"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da38ec0a-f37d-4a5c-8da0-93410a8fb475"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "181d142b-a1d2-40c7-919b-2bfaf1cb98b1", "name": "tr(r:p1rdt486-p1rdt486lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd2f4b00-6e8b-4faa-a760-7c28f8d36a36"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5401d366-a5a2-4753-82b7-ce4fa08a1227"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5401d366-a5a2-4753-82b7-ce4fa08a1227"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "e13b87a6-1453-493b-90f8-63417bffadc3", "name": "tr(r:p1rdt487-p1rdt487lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfb0d992-ab18-4f73-933e-a01ce73ef3b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47fbd02f-6c12-4bd6-9d6d-2e0cddbfcd88"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47fbd02f-6c12-4bd6-9d6d-2e0cddbfcd88"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "bea3ce73-1bb4-443c-82bc-d9633e9913c4", "name": "tr(r:p1rdt488-p1rdt488lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fa474a3-1d6b-454b-9170-6a8d13789c43"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e517b810-e6b9-4c89-b47d-1921fcf88edc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e517b810-e6b9-4c89-b47d-1921fcf88edc"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d221e7c0-5e3a-459f-9f2a-d00e62491d88", "name": "tr(r:p1rdt489-p1rdt489lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cee642e7-12f0-4746-841e-d8cda6fff57e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25637062-8ca3-4694-a27b-7be93e89fe1f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25637062-8ca3-4694-a27b-7be93e89fe1f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "948d2dba-9df5-4bb4-af04-fb9494f3d65b", "name": "tr(r:p1rdt3776-p1rdt3776lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "170a2bcb-d7ce-4617-855b-9111b84262ed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ae14df0-ab3b-47ba-9f83-c09f03999c76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ae14df0-ab3b-47ba-9f83-c09f03999c76"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "bea0945a-b96b-4d1e-af74-0291cbd1a874", "name": "tr(r:p1rdt3777-p1rdt3777lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f9af980-79c4-4daf-b8fc-44e02953f98b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4662f3f5-e75b-4b75-a6d6-7ada745d5cca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4662f3f5-e75b-4b75-a6d6-7ada745d5cca"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1c340bc5-1d86-44e6-860a-aa40bf29d777", "name": "tr(r:p1rdt5098-p1rdt5098lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9100fbd6-863e-48b2-94ed-aca1ef0947bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e734d7a2-9161-41c0-ba78-9f9f87120acd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e734d7a2-9161-41c0-ba78-9f9f87120acd"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "7f4eefd7-8cd4-4fbc-b0c6-c16c3485fc58", "name": "tr(r:p1rdt5548-p1rdt5548lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bf1b63d-fbce-42f8-9948-2e09bfa67409"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91754be7-2a91-4a0e-9856-43d08ecc7c70"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91754be7-2a91-4a0e-9856-43d08ecc7c70"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "9ccccbb6-1805-4071-91ed-04ab43c1c51c", "name": "tr(r:p1rdt5551-p1rdt5551lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f7fed4f-197e-4a79-97e5-df595377736b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9dec144-ef2e-44fe-990a-c9d70b740410"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "c1bbd3f0-4b5f-4f5e-9f82-e2b15dd3929a", "name": "tr(r:p1rdt5557-p1rdt5557lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cca8918c-30e6-4619-a5e0-8c0d3451f9c4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05b867e6-2f18-49e7-9869-55bd5048c201"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05b867e6-2f18-49e7-9869-55bd5048c201"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "28066d5a-8a37-45e6-9713-935dbb6c1a49", "name": "tr(r:p1rdt5560-p1rdt5560lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68117bef-16c5-40c9-9356-76ef5c056650"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5838960-8556-4e4a-95e9-8ba9ffc85141"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5838960-8556-4e4a-95e9-8ba9ffc85141"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "16844ce2-d0e7-4577-8d19-df2522470625", "name": "tr(r:p1rdt5561-p1rdt5561lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "756f6cd8-301b-4fac-b414-d72853616c6e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "133a0221-0cd5-46d2-af84-e80e7951c96d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "133a0221-0cd5-46d2-af84-e80e7951c96d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "eab10644-9384-4c94-aa36-fb0daba50b19", "name": "tr(r:p1rdt5563-p1rdt5563lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad24f98d-f022-4e62-b80b-426052810759"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a150dd3-61a4-4df9-90e2-6c72f80af819"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "9a8345b1-a786-435c-b6a2-aa53580a9679", "name": "tr(r:p1rdt5564-p1rdt5564lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8444c9ea-ff7a-4b0a-9ea6-9c18770565cb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8deb73b9-51fc-447d-9da7-14a6dccff646"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8deb73b9-51fc-447d-9da7-14a6dccff646"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "3e20fcc3-e522-405e-b12e-8621cb7b680c", "name": "tr(r:p1rdt5565-p1rdt5565lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5e479d3-aae0-47b8-b707-bad1191df1e7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60dc1291-a843-4abf-bfc6-ff8afc8c0b98"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "ec61176f-dfbb-4efa-9041-5ed2ff4bf1e3", "name": "tr(r:p1rdt5566-p1rdt5566lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fed9557-b170-4817-8bd8-efc3b9f7c982"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95a5450a-6630-41b8-863f-0c1f3fcfa7ab"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95a5450a-6630-41b8-863f-0c1f3fcfa7ab"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "947b40bb-4805-40ad-a01b-6cf8e7426679", "name": "tr(r:p1rdt5568-p1rdt5568lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c83b6ee-20fc-4ca0-a778-44735283afd5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "613d178b-a566-408d-bad0-e4a170eea971"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "613d178b-a566-408d-bad0-e4a170eea971"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "64da0817-f4a8-4b5f-821e-148131beb92e", "name": "tr(r:p1rdt5574-p1rdt5574lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9906676-e9b9-4d51-b1c2-a6b6fe187faa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "248e065d-80ed-4926-9625-295c83da6b61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "248e065d-80ed-4926-9625-295c83da6b61"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "999c9328-68fe-4d34-86d9-ce9c7fb60c2f", "name": "tr(r:p1rdt5577-p1rdt5577lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1c8b424-4509-4fd2-93e2-4fd54f6cf49a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21ef4ae6-b80e-49f1-8d00-1cb6e27bc8f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21ef4ae6-b80e-49f1-8d00-1cb6e27bc8f9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "e453767e-243b-4848-8e6f-d4589c09194a", "name": "tr(r:p1rdt6261-p1rdt6261lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53e5fee4-5a31-448e-8bd0-d8996468d085"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9859b30-0238-493e-be1a-cb6717413ba9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9859b30-0238-493e-be1a-cb6717413ba9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d1f70d0a-2390-439b-9b24-5f2fd1ba1b0e", "name": "tr(r:p1rdt6262-p1rdt6262lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf092ec9-ecda-4216-9ac0-0bc035973515"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2172b57-622b-44c1-8388-f1e2b1def312"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2172b57-622b-44c1-8388-f1e2b1def312"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4c14ecdf-6121-49db-8273-ea7012401a9f", "name": "tr(r:p1rdt6263-p1rdt6263lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c61df077-693e-4e67-aea6-ee60b99406d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4717b000-fd39-4647-9fbd-5152323dacee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4717b000-fd39-4647-9fbd-5152323dacee"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f6f3fa51-a1a9-40ca-a3b6-7a6ccdb26701", "name": "tr(r:p1rdt6264-p1rdt6264lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a03d20d-664a-4e80-abec-a36910787829"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e916c16-525d-4092-b627-ad44b4bf4ee8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e916c16-525d-4092-b627-ad44b4bf4ee8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "836aa093-a7b6-4940-8c75-2a7058b9fd71", "name": "tr(r:p1rdt6265-p1rdt6265lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d316c13-77c1-4412-baf9-801f7e5ae407"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6bb5544-e583-4ded-9a10-23be70f5598e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6bb5544-e583-4ded-9a10-23be70f5598e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a7f86fff-0adf-4b9e-a9b6-97e3117ec95b", "name": "tr(r:p1rdt6266-p1rdt6266lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e22d08f0-2afc-426a-a0c0-6b00cc1103aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8af5f9d5-965c-4a0c-a811-67d3bed744ee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8af5f9d5-965c-4a0c-a811-67d3bed744ee"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "30021e75-15ad-4990-ba5f-192e884daaac", "name": "tr(r:p1rdt6267-p1rdt6267lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a1d9cfa7-0024-4896-a263-2715086f2ad6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0ddd898-3193-4bff-80f4-fd4a7eae9aec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0ddd898-3193-4bff-80f4-fd4a7eae9aec"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "5db55ec0-9b26-43e1-82d6-1c6f792b80a2", "name": "tr(r:p1rdt6488-p1rdt6488lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63b2f1e6-5e15-4433-85ee-ff7bb7218b96"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1155c2c-544c-45f4-969f-b3ec4f6773bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1155c2c-544c-45f4-969f-b3ec4f6773bb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "cca02abb-5240-4ef2-a315-f28e00a41488", "name": "tr(r:p1rdt6578-p1rdt6578lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e257530-1fe2-410b-83a1-57789e6ddeda"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "555453a3-3fb7-426a-bbd2-9e588d4bd01d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "555453a3-3fb7-426a-bbd2-9e588d4bd01d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "82e64de1-effc-4dc0-8ddc-bb009d05dc60", "name": "tr(r:p1rdt6580-p1rdt6580lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68298e92-fca3-44e9-9271-f79be47c9c63"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5de250a8-ecca-4ab4-9f09-685aaf92d13d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5de250a8-ecca-4ab4-9f09-685aaf92d13d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "405b2028-87da-44cf-b232-708b560b6d4b", "name": "tr(r:p1rdt6584-p1rdt6584lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9f273a36-c30d-4962-81f4-26f8d20e1cf4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d944119-3782-49dd-8b24-1f68d8ee687c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d944119-3782-49dd-8b24-1f68d8ee687c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "c275a539-c206-4c1b-b36e-ae22a3bf13dc", "name": "tr(r:p1rdt6587-p1rdt6587lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d77add8e-ba22-4b44-9c0b-0bddc251a573"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c587698-7940-4edb-9105-f31f1304f7e9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c587698-7940-4edb-9105-f31f1304f7e9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "8aca787a-f329-4a51-90aa-09e490eaa499", "name": "tr(r:p1rdt6588-p1rdt6588lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1648fe3-a7f9-47aa-b168-d2b56cf220e7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61045f72-ca3d-4e0d-ac3d-db5fbf099b38"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61045f72-ca3d-4e0d-ac3d-db5fbf099b38"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "95128a03-d470-48ae-9a19-83abda77d90b", "name": "tr(r:p1rdt6590-p1rdt6590lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5291ea2b-6990-407b-b8d4-d6868bf37310"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a289017a-8ab9-4412-857a-694b3aa2c63d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a289017a-8ab9-4412-857a-694b3aa2c63d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "0672aaa6-8f76-454c-95bd-e281f1293e08", "name": "tr(r:p1rdt6591-p1rdt6591lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1d0a85a-62dc-46d2-bae1-d43d07743a34"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a7c2e99-857f-4119-be4a-daaca586f056"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a7c2e99-857f-4119-be4a-daaca586f056"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "43ad826f-468f-4f62-98d4-419243839bab", "name": "tr(r:p1rdt7286-p1rdt7286lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02351140-e632-49e2-83e4-7e5bc1c8856a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ad975da-cce7-49cb-be78-20c4abf8975e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ad975da-cce7-49cb-be78-20c4abf8975e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b64f19d8-c621-4f06-afaa-159a18f970d5", "name": "tr(r:p1rdt7289-p1rdt7289lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f8375b7-7bdd-409c-9fa1-5c13bd233364"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56d21681-3c57-4575-af17-f2bbf9874a10"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56d21681-3c57-4575-af17-f2bbf9874a10"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f9343681-c623-4b98-830a-4a29714dd9c3", "name": "tr(r:p1rdt7293-p1rdt7293lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4afa9bec-d8da-4449-ab96-9f875bae3c33"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9b0c16f-f433-4aa1-8d00-dc1573dfb5e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9b0c16f-f433-4aa1-8d00-dc1573dfb5e3"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "60823e00-c5b4-4bc4-b042-fad0c40a99f2", "name": "tr(r:p1rdt7294-p1rdt7294lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a955da2d-e212-4026-b1fb-0021a04ded07"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67d2b31-f05a-4160-83ae-55154224a9ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67d2b31-f05a-4160-83ae-55154224a9ca"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "74ab20a7-57a7-4622-ae93-7d3d717abc43", "name": "tr(r:p1rdt7299-p1rdt7299lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d065da7b-7e88-4e63-a47c-959f4d4c6e1c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4cee417a-3410-4907-8621-f0d3fcbc047c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4cee417a-3410-4907-8621-f0d3fcbc047c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "169914f1-885b-4f8c-8e51-c5f5b78521a8", "name": "tr(r:p1rdt7300-p1rdt7300lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05f14a3e-053e-4b65-b962-da7804b9e2c1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "135a6a49-6562-4c6e-a41f-f5f78c0ac3e6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "135a6a49-6562-4c6e-a41f-f5f78c0ac3e6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "de07b9e3-46b7-43d8-be06-8daf46d20cfd", "name": "tr(r:p1rdt7303-p1rdt7303lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6f24e3a-088a-4d1b-8292-03015289d88e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7cbc8145-b198-46f1-a3fd-55a05637e618"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7cbc8145-b198-46f1-a3fd-55a05637e618"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c7531bac-a558-4fc5-abb3-cad5e268ecb0", "name": "tr(r:p1rdt7308-p1rdt7308lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2e605b4-fe7a-4571-947d-8ae19de627d8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5094655-6494-44a9-b0ff-c5b418dcc11e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5094655-6494-44a9-b0ff-c5b418dcc11e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "3d21883c-9d1b-4ac2-882a-5f72cfb7a512", "name": "tr(r:p1rdt7316-p1rdt7316lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6322bf4d-0976-4bae-94c0-f76f83ccb9bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a289e26d-2d86-4fdf-942b-881b91ca18eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a289e26d-2d86-4fdf-942b-881b91ca18eb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c412fc0f-8313-41e6-84c6-5d4022182b14", "name": "tr(r:p1rdt7317-p1rdt7317lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48efebbb-c70a-47d3-aae3-0e39088fc455"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16c465cf-c4ae-4702-ba6c-0b7704eda764"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16c465cf-c4ae-4702-ba6c-0b7704eda764"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "fa23fabe-02fd-4549-80aa-192a59aeac79", "name": "tr(r:p1rdt7321-p1rdt7321lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b468be25-1324-46ab-9424-887741ca1134"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c855f7bb-1f33-4c3e-9deb-e3f9c5aba07d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c855f7bb-1f33-4c3e-9deb-e3f9c5aba07d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "94144af1-4cd0-49b9-aa6a-bb93661492f8", "name": "tr(r:p1rdt7737-p1rdt7737lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d2ea25e-3d48-4b1d-9e52-768752de2e09"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35be767a-53a1-4fe1-b320-9542dd859d97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35be767a-53a1-4fe1-b320-9542dd859d97"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "53d064dd-1417-4642-8abf-df6fd0b5bb7b", "name": "tr(r:p1rdt7753-p1rdt7753lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d142315b-a247-4a4d-a178-73e3c150a188"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7482f0c-eb85-4e30-a09a-eb9f15bbc22b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7482f0c-eb85-4e30-a09a-eb9f15bbc22b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "05232de7-0f14-4d8a-8559-1177a07f9e5e", "name": "tr(r:p1rdt7757-p1rdt7757lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "081feb5c-d5d5-405e-85d4-f1dd0916fc3d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d343e634-0936-4f21-9e2c-079e19f0dfa1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d343e634-0936-4f21-9e2c-079e19f0dfa1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "51d1c01e-6f22-46ea-8d46-dd93a1b50d2e", "name": "tr(r:p1rdt7791-p1rdt7791lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4413ca7f-fdd1-484e-a0ba-3ff2447ebfef"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28e5f84f-2fac-4b5c-a669-b16988e4d6ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28e5f84f-2fac-4b5c-a669-b16988e4d6ae"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "eb25695e-13e8-42e0-a678-e5405a877c1f", "name": "tr(r:p1rdt7795-p1rdt7795lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bee93ff6-6ff8-4572-b339-c8e897dac81b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3959f944-18f5-4daa-a454-3c6bfb7158ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3959f944-18f5-4daa-a454-3c6bfb7158ff"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b2fecd2c-00e0-43d7-9dc2-60a9fddea649", "name": "tr(r:p1rdt8105-p1rdt8105lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3f91816-7c3f-4fc7-98a5-6dee55e52e9f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b2ec0ba-a854-4631-b97a-4674123d6fe6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b2ec0ba-a854-4631-b97a-4674123d6fe6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1b65440f-5d1e-4c19-b277-993ab8fb0f7b", "name": "tr(r:p1rdt8111-p1rdt8111lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2c69fef-4afb-4bb3-9828-096b812de54a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b639e55-2e33-4582-bb96-06a9d33a3419"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b639e55-2e33-4582-bb96-06a9d33a3419"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "8183c724-3202-4128-b82b-1bc73f3b6420", "name": "tr(r:p1rdt8138-p1rdt8138lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17b633c6-214d-4428-bded-df737f50ffb6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dca9b40e-ed8a-4f75-a703-91539f6c3075"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dca9b40e-ed8a-4f75-a703-91539f6c3075"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "be148e43-4847-4b1e-a963-f6389733140c", "name": "tr(r:p1rdt8146-p1rdt8146lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc34073b-94f6-4c75-8144-8f624bac9cc7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2bee3961-990e-47ac-b49b-d305f8fe0af8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2bee3961-990e-47ac-b49b-d305f8fe0af8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "dddabe2e-2289-4b4b-a2fc-1b5d8b82f030", "name": "tr(r:p1rdt8167-p1rdt8167lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eb3d4eb-71fc-46f3-b588-d223568c411c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "07bd9128-3c6c-4b6e-a209-1ac8b348eaa9", "name": "tr(r:p1rdt8169-p1rdt8169lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6bdb2cf-9373-4d56-a5f9-cb8fa9c67e55"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6349165a-d47a-4cf4-84f9-df5c5f3a0e98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6349165a-d47a-4cf4-84f9-df5c5f3a0e98"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "3205df5e-6618-4256-9cfd-c5dc7b254caa", "name": "tr(r:p1rdt8174-p1rdt8174lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b0f9433-e0a3-458a-8687-c9cf38d0bbb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4903e82a-8cfb-406e-b4bf-5e01068419a3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4903e82a-8cfb-406e-b4bf-5e01068419a3"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "ae939404-c5bd-43ff-931a-6c0769508bc9", "name": "tr(r:p1rdt8180-p1rdt8180lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c93a476-4ad5-41cd-a07b-e2ccc9ef2c3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8e03b63-853e-4cfe-bf4a-3779b2026637"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8e03b63-853e-4cfe-bf4a-3779b2026637"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "63f53b80-31a5-4067-85a7-637448289748", "name": "tr(r:p1rdt8195-p1rdt8195lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8997dae6-8970-4762-98e9-0617375633d6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "782d6008-7fec-46b6-9461-9e33b79539d3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "782d6008-7fec-46b6-9461-9e33b79539d3"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "ce4d8ec3-56e8-4acc-b3b0-dad1fdf76ef5", "name": "tr(r:p1rdt8201-p1rdt8201lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e3d41a7-06a4-460b-aa6c-3a60c8d2de10"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76e33e4f-05be-44d1-a503-fed82b4da974"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76e33e4f-05be-44d1-a503-fed82b4da974"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "4edc8596-210a-4531-a238-d6738acb9e34", "name": "tr(r:p1rdt9055-p1rdt9055lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "246ad62e-5a10-4031-94e7-1732f58f1da9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c1f6cd8-cde1-45cc-87ca-1355efa38077"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c1f6cd8-cde1-45cc-87ca-1355efa38077"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d20d0070-3f40-4462-90d1-9e42dd91adc4", "name": "tr(r:p1rdt9086-p1rdt9086lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75ee3b24-7407-45ba-94d5-abe187306f13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "afb4c195-8bb6-47d5-88f3-76adb9cda250"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "afb4c195-8bb6-47d5-88f3-76adb9cda250"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "766f3347-7aa4-4383-9703-9c0be50e9d7a", "name": "tr(r:p1rdt16394-p1rdt16394lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5b51836-1807-4fab-b877-94a62021569f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40b03cbe-470d-493a-854a-900557ac20c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40b03cbe-470d-493a-854a-900557ac20c8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "40c5e673-05ab-4012-9c8c-7bf871603311", "name": "tr(r:p1rdt16404-p1rdt16404lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61d5dee2-30f8-434d-8c03-76bccff72549"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38b0bd7c-0898-497f-bb24-4add0fd92932"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38b0bd7c-0898-497f-bb24-4add0fd92932"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "e4a24b59-1b02-49fe-8ef5-030327f3023e", "name": "tr(r:p1rdt16424-p1rdt16424lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "18e3da78-83fc-4b8e-9d45-41adb9b753ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23775c66-0b90-443d-8566-491405876e9d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23775c66-0b90-443d-8566-491405876e9d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "484f938d-d59b-4115-9cb2-2685a7b7a2cd", "name": "tr(r:p1rdt16427-p1rdt16427lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d50d3e76-470b-47c2-ada2-da944962b322"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "980376ed-54fd-434c-b58e-0bbd6eaa9954"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "980376ed-54fd-434c-b58e-0bbd6eaa9954"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "449a26bb-c9e0-421e-b94b-a44f94290b59", "name": "tr(r:p1rdt16603-p1rdt16603lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5a9e0f5-d824-4a76-a4f0-88aab072280e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26bc650a-6838-4320-8afa-b8d2f22e96e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26bc650a-6838-4320-8afa-b8d2f22e96e8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "793b342a-db39-473d-bd79-9522eb670aa7", "name": "tr(r:p1rdt16604-p1rdt16604lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98a946e8-3c8a-49ec-be8a-5610c7fc596c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d31da07-e20a-4fb8-95f4-d91450395471"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d31da07-e20a-4fb8-95f4-d91450395471"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4f26c64f-b8eb-4b58-bb0c-13d80ceb0d14", "name": "tr(r:p1rdt16787-p1rdt16787lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4bc644c-9875-4846-8b0f-dfa0568de623"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4a3b828-bddf-4314-b9a5-03b9dfcd2618"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4a3b828-bddf-4314-b9a5-03b9dfcd2618"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "76b84fae-6335-4869-b08d-8984583dd282", "name": "tr(r:p1rdt16790-p1rdt16790lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4774ed1a-85ec-4ca0-8e9a-3b232588fb0c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c261090-bc22-4d81-9a9e-75227cd7c99e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c261090-bc22-4d81-9a9e-75227cd7c99e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "857e2066-6f60-4b44-8d3c-02354b5fd872", "name": "tr(r:p1rdt16847-p1rdt16847lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e35a4f7-19c1-4f59-9adc-b267f6088264"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1abef1d-4ffc-4696-91ca-e81ac36cce61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1abef1d-4ffc-4696-91ca-e81ac36cce61"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "383a2c28-1707-4345-a2fd-dd5fc492cc54", "name": "tr(r:p1rdt16911-p1rdt16911lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "725fbd98-74ba-4143-8947-da9fdc209889"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0df1550a-7e69-42e9-8059-3a36ecb3d253"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0df1550a-7e69-42e9-8059-3a36ecb3d253"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a2ab4202-af90-45ce-b38a-724c78d23cda", "name": "tr(r:p1rdt7711-p1rdt7711lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2131350-dc34-4d8d-8c9f-c29e25bc654c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64b60527-0853-4973-8d7a-78ba5e377799"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "d0a1b468-f2c0-460e-b454-e11535f6f969", "name": "tr(r:p1rdt8473-p1rdt8473lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3a83211-0829-4e2c-b618-3f1fcaba3e87"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "439728c5-fee5-4dfa-9894-261ba6c40e95"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "6ebf15d5-5f87-45c8-b7ce-35edd541c885", "name": "tr(r:p1rdt6028-p1rdt6028lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e39cb1db-d6a6-4b6c-bc73-920e0c34c292"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35f6f747-811d-4fe2-a9c7-991248572c74"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "df70495a-02d7-450a-9a65-9e0b6b42b83f", "name": "tr(r:p1rdt9478-p1rdt9478lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c49b6e87-5834-4e7e-a64c-b4ec0f7d4995"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddf38626-1223-429f-a903-98f1c975020b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "c3da3337-5527-44f4-b208-3bbfe346a0fe", "name": "tr(r:p1rdt6232-p1rdt6232lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b59ad93a-cca2-4a77-8515-a645ddd2a320"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e2630e1-a215-4740-9327-fa004e89863d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "68bf215e-2a75-42a5-be1c-54396a95a2cf", "name": "tr(r:p1rdt8493-p1rdt8493lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfb41891-7063-44b8-9286-1fe763e49924"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c330731a-fd2c-40c7-8fce-94f7e17cf6d9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "21c9d6f7-778e-45ae-9eee-c04828838596", "name": "tr(r:p1rdt93-p1rdt93lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "900d49ce-4834-4f99-8d74-a5e9d2f63ea0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0921e58d-1ada-4556-8b01-8f22d3bf4ee2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0921e58d-1ada-4556-8b01-8f22d3bf4ee2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "4987fad3-04f3-4a44-9e95-4c76bb8da481", "name": "tr(r:p1rdt99-p1rdt99lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "092a9d51-a39c-4c05-905e-93fb1ae96ba2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef6be92d-5d1b-40e2-a2c2-9d0c1f0bf596"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef6be92d-5d1b-40e2-a2c2-9d0c1f0bf596"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "66884d82-d8ad-43ea-b952-5bef9472cc31", "name": "tr(r:p1rdt101-p1rdt101lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d8e5d83-cd9c-4527-9eef-6219c98dfe93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1277a701-9fbd-4853-a809-962475e016c4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1277a701-9fbd-4853-a809-962475e016c4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "b91fce2e-6543-43ed-b024-f99717df76a9", "name": "tr(r:p1rdt108-p1rdt108lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e61ce952-a643-45aa-a466-8aa15ecceb48"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3aa8d6f2-8d84-42d6-8e7b-89e3b1efa03c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3aa8d6f2-8d84-42d6-8e7b-89e3b1efa03c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "d4442785-5a57-40fb-9428-4491355af6e1", "name": "tr(r:p1rdt6121-p1rdt6121lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2390c014-d418-4d63-8438-529a036487db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "448cc5e0-391f-4a6b-8199-25cef4593edf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "448cc5e0-391f-4a6b-8199-25cef4593edf"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "59985662-1964-4761-9713-7d3f9e638929", "name": "tr(r:p1rdt6123-p1rdt6123lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17f807ba-6ad6-4fd9-9dd0-2c0bacea5b24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e81ba94-5857-42e4-aeee-58542cef0fb6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e81ba94-5857-42e4-aeee-58542cef0fb6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "afa627b8-bda7-4883-9053-6fe4ad39ebd2", "name": "tr(r:p1rdt8017-p1rdt8017lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6378abd-969e-4ec8-93eb-2cc39cdb18eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8428de0e-4b06-4f19-bffb-5fed32f96f67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8428de0e-4b06-4f19-bffb-5fed32f96f67"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "101e3b64-572d-4af1-b520-d6b982c7e99e", "name": "tr(r:p1rdt8043-p1rdt8043lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "691c1909-3b71-4e07-abf0-95aaabfa23bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a367e687-b29a-44b4-a943-7b94762e549e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a367e687-b29a-44b4-a943-7b94762e549e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b52a1ec1-eb6d-4410-9a09-fb90b84cc806", "name": "tr(r:p1rdt8065-p1rdt8065lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "862f3566-9443-4b82-8f05-c994581e131a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8bb025c5-31eb-4771-b433-e1dcad03b3ed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8bb025c5-31eb-4771-b433-e1dcad03b3ed"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ac790f59-9dc9-42c3-b7b0-7e682faa07f7", "name": "tr(r:p1rdt8068-p1rdt8068lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f5fbb8b-0c32-4aa7-acaf-7ea2b5e56505"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd01eed6-0e70-42e7-ac29-4bfd2f70366a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd01eed6-0e70-42e7-ac29-4bfd2f70366a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a999665e-c3af-4abd-a73a-56e5afe42a96", "name": "tr(r:p1rdt8070-p1rdt8070lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473520c7-0098-4bc2-a46f-07efd6c3759c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0bcd460-ccf2-42ee-83c6-bada397ab4d6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0bcd460-ccf2-42ee-83c6-bada397ab4d6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "ff4316bf-2fdf-402e-933a-1d92eec8d30e", "name": "tr(r:p1rdt8190-p1rdt8190lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a761aef-a766-40e2-b8d7-e5a918cece18"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f21f4e99-8877-4bb0-9956-9240bc6db3d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f21f4e99-8877-4bb0-9956-9240bc6db3d1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1fa55d6c-fec8-4ebc-baad-a862692ee4e1", "name": "tr(r:p1rdt8204-p1rdt8204lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa2342e6-2d40-424a-830c-a84af4632b6e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d12bf6fb-8dac-4729-bcda-1ee61c63f6e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d12bf6fb-8dac-4729-bcda-1ee61c63f6e8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "029066e1-edb3-4a44-997d-76fbe7264dd0", "name": "tr(r:p1rdt8208-p1rdt8208lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e2b4d77-2388-4897-86fe-06409fa9d222"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ecf11723-eb6d-423c-ac0c-85fa2d1ba846"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ecf11723-eb6d-423c-ac0c-85fa2d1ba846"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6a8d6f6f-b19a-43dc-a86f-18dfc67b7451", "name": "tr(r:p1rdt8578-p1rdt8578lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb866499-9e9c-4394-bd76-d4320ba4934b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1a593e3-4735-47d2-b893-dd2d07c3c47c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1a593e3-4735-47d2-b893-dd2d07c3c47c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1a547192-d0a9-4174-8c47-f8a34d6a8321", "name": "tr(r:p1rdt8583-p1rdt8583lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dbb79e10-21ba-4f04-b8a3-0cf711d26d40"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "134bac3d-5b7e-48d7-950e-01e5b7d43852"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "134bac3d-5b7e-48d7-950e-01e5b7d43852"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d5409af6-e60a-4f61-af90-35c4c7a32310", "name": "tr(r:p1rdt8584-p1rdt8584lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b601580-3091-4d8c-9718-1367c7ed385f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8ba1042-fcfd-47a8-aa0f-8b13618d3212"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8ba1042-fcfd-47a8-aa0f-8b13618d3212"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "21bda883-4037-4b29-95fc-2e5d0c901e4e", "name": "tr(r:p1rdt10491-p1rdt10491lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4737e613-8cf5-45d7-a3f5-71af051ece4c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8f14e6e-ee96-4ae9-86ba-4a07cf103b65"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8f14e6e-ee96-4ae9-86ba-4a07cf103b65"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482", "name": "", "limit_type": "max", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "base"}}, "value": {"value": 600.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}}, {"uuid": "d17ac250-39de-4755-ab93-d93c9ffec1f4", "name": "3974db24-e8e2-4dea-b6b3-1ce29ed132c9", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 1200.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "33fd2b05-630e-42ac-9ccf-60a8ee3f45c9", "name": "7273acf0-19b9-4e4c-b23c-268bdb215a51", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 900.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "14ee131a-95b9-49c5-b11d-450705732a22", "name": "51a33b90-9eee-4646-b0aa-862f7255c6b3", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 165.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "6ba5defb-3101-4ef8-8d06-36719f7dad94", "name": "27d4ced8-b2f8-4ebb-af19-64e0d6a72831", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 151.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "fa89ef5e-f965-457f-a553-4831f61b03c7", "name": "c53fbbfe-4cda-4768-ab94-259d70acb568", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 301.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "cbd826fb-5ba3-44b3-9c68-e5792dbd9854", "name": "62927506-2fbe-4764-b56a-e2ec536f5a4d", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 205.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "99530725-fc4c-4216-8e67-a4469035c280", "name": "0c3473a8-3f24-4fba-b819-b37916068d57", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 295.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523", "name": "179bf9a8-7aaa-4d22-8e36-ca540eaba4ff", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 325.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "fc796329-2b2a-43b9-80c9-88427ef9b994", "name": "0806190a-92f7-42c1-b527-04504919e640", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 233.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "4900e609-ebb1-44db-852b-602449095f15", "name": "5df7dfb1-43ab-41a2-9a13-560098cbf260", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 205.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "40a26197-da2a-4e22-a50a-3922efd7762c", "name": "08f3b6b5-1bbd-40e6-8b34-a1d59d7b57e2", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0412]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.7627]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[7.69673]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 165.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "3baa725a-9b39-45f8-86af-c6afda2cdf9f", "name": "92be5f47-025f-41ac-a0e4-09323ff980fd", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "2419ddcd-627b-4faa-9878-65d4baf7d064", "name": "c9f25e4e-fbf4-4152-a503-2fdd1553b4c9", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "ab2720f4-bdaa-4e93-a718-9d3398ce76a4", "name": "840ea5ca-ca79-4640-abfc-a248810bef2f", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 301.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "c01372a2-4296-4877-a1f3-dd8c06d37f74", "name": "f3d3a255-32e5-4fb0-9516-d898bf9ec850", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 370.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "42f228c5-d3cc-4ea7-9d1c-029acf33213c", "name": "3p_oh_code_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.22464633333333334, 0.05016533333333334, 0.05016533333333334], [0.05016533333333334, 0.22464633333333334, 0.05016533333333334], [0.05016533333333334, 0.05016533333333334, 0.22464633333333334]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.631065, 0.188089, 0.188089], [0.188089, 0.631065, 0.188089], [0.188089, 0.188089, 0.631065]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[2.8000000000000003, -0.6, -0.6], [-0.6, 2.8000000000000003, -0.6], [-0.6, -0.6, 2.8000000000000003]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 480.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "72184ad1-d36c-4223-8c4b-6bdd0563907c", "name": "breaker_13kv_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1e-05, 0.0, 0.0], [0.0, 1e-05, 0.0], [0.0, 0.0, 1e-05]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1e-05, 0.0, 0.0], [0.0, 1e-05, 0.0], [0.0, 0.0, 1e-05]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[2.8000000000000003, -0.6, -0.6], [-0.6, 2.8000000000000003, -0.6], [-0.6, -0.6, 2.8000000000000003]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 1200.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "9faab192-2f24-4afc-9a9c-210e7b431e38", "name": "breaker_69kv_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1e-05, 0.0, 0.0], [0.0, 1e-05, 0.0], [0.0, 0.0, 1e-05]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1e-05, 0.0, 0.0], [0.0, 1e-05, 0.0], [0.0, 0.0, 1e-05]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[2.8000000000000003, -0.6, -0.6], [-0.6, 2.8000000000000003, -0.6], [-0.6, -0.6, 2.8000000000000003]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 900.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0", "name": "1p_oh_al_4_periwinkle_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.7609666666666666, 0.3959666666666668], [0.3959666666666668, 1.7609666666666666]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.6698333333333334, 0.5686333333333333], [0.5686333333333333, 0.6698333333333334]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[36.92503333333334, -17.558966666666667], [-17.558966666666667, 36.92503333333334]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934", "name": "1p_oh_al_4/0_zuzara_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.4728, 0.20209999999999997], [0.20209999999999997, 0.4728]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.21353333333333335, 0.12473333333333335], [0.12473333333333335, 0.21353333333333335]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[41.3578, -20.447400000000002], [-20.447400000000002, 41.3578]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580", "name": "1p_oh_al_2/0_rucina_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.7166333333333332, 0.28753333333333336], [0.28753333333333336, 0.7166333333333332]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.28883333333333333, 0.1932333333333333], [0.1932333333333333, 0.28883333333333333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[39.3595, -19.342100000000002], [-19.342100000000002, 39.3595]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "2d347746-0969-4a8a-b986-c40ef4f4c015", "name": "1p_oh_al_2/0_rucina_2_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.7166333333333332, 0.28753333333333336], [0.28753333333333336, 0.7166333333333332]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.28883333333333333, 0.1932333333333333], [0.1932333333333333, 0.28883333333333333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[39.3595, -19.342100000000002], [-19.342100000000002, 39.3595]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 300.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f", "name": "1p_ug_al_1/0_brenau_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.9149, 0.3744], [0.3744, 0.9149]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.4972667, 0.3969667], [0.3969667, 0.4972667]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[36.4998, -16.313099999999995], [-16.313099999999995, 36.4998]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 205.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "09abe480-4eaa-43f7-a172-88856f758284", "name": "1p_oh_al_2/0_rucina_2_5", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.7166333333333332, 0.28753333333333336], [0.28753333333333336, 0.7166333333333332]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.28883333333333333, 0.1932333333333333], [0.1932333333333333, 0.28883333333333333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[39.3595, -19.342100000000002], [-19.342100000000002, 39.3595]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 233.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "3c9c08f9-58e9-4367-aee8-72788caa6a7c", "name": "1p_ug_al_2/0_converse_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.7793333, 0.3503333], [0.3503333, 0.7793333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.4209333, 0.3231333], [0.3231333, 0.4209333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[37.42527, -17.11183], [-17.11183, 37.42527]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 233.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398", "name": "1p_ug_al_4/0_sweetbriar_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.5462333, 0.2755333], [0.2755333, 0.5462333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.2976, 0.2043], [0.2043, 0.2976]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[39.3278, -18.6046], [-18.6046, 39.3278]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 301.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "97e8fcf2-7304-40bf-ae9b-e7cdd37a4fb7", "name": "1p_oh_al_4/0_zuzara_2_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.4728, 0.20209999999999997], [0.20209999999999997, 0.4728]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.21353333333333335, 0.12473333333333335], [0.12473333333333335, 0.21353333333333335]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[41.3578, -20.447400000000002], [-20.447400000000002, 41.3578]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 165.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "52d0c8fb-a66f-4033-93f4-79e9ae946d79", "name": "1p_oh_al_2/0_rucina_2_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.7166333333333332, 0.28753333333333336], [0.28753333333333336, 0.7166333333333332]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.28883333333333333, 0.1932333333333333], [0.1932333333333333, 0.28883333333333333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[39.3595, -19.342100000000002], [-19.342100000000002, 39.3595]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 165.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137", "name": "1p_oh_al_acsr_#2_sparrow_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0412]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.7627]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[7.69673]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 165.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "1369a137-ea26-496f-a49e-07fe1c36db1c", "name": "1p_ug_al_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.9176999999999998]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.9546999999999999]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[158.492]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 151.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "6148f90f-6cfa-4038-a641-2905e51ba219", "name": "3p_oh_al_acsr_4/0_penguin_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.3635667, 0.09006667, 0.09006667], [0.09006667, 0.3635667, 0.09006667], [0.09006667, 0.09006667, 0.3635667]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.6385333, 0.2202333, 0.2202333], [0.2202333, 0.6385333, 0.2202333], [0.2202333, 0.2202333, 0.6385333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[7.4482669999999995, -3.1846329999999994, -3.1846329999999994], [-3.1846329999999994, 7.4482669999999995, -3.1846329999999994], [-3.1846329999999994, -3.1846329999999994, 7.4482669999999995]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 325.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "39368021-558c-46e1-b3b2-1376e7863046", "name": "3p_ug_al_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.3289333, 0.05923333, 0.05923333], [0.05923333, 0.3289333, 0.05923333], [0.05923333, 0.05923333, 0.3289333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.9076, 0.6647, 0.6647], [0.6647, 0.9076, 0.6647], [0.6647, 0.6647, 0.9076]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[120.289, -59.026, -59.026], [-59.026, 120.289, -59.026], [-59.026, -59.026, 120.289]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 295.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9", "name": "3p_ug_al_350kcmil_3_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.3388667, 0.1744667, 0.1744667], [0.1744667, 0.3388667, 0.1744667], [0.1744667, 0.1744667, 0.3388667]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.5126, 0.2912, 0.2912], [0.2912, 0.5126, 0.2912], [0.2912, 0.2912, 0.5126]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[164.36499999999998, -81.63499999999999, -81.63499999999999], [-81.63499999999999, 164.36499999999998, -81.63499999999999], [-81.63499999999999, -81.63499999999999, 164.36499999999998]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 370.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "3bc006be-04ae-45f9-8629-fd4cc42dcf20", "name": "3p_oh_al_acsr_1033kcmil_curlew_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.0871, 0.0296, 0.0296], [0.0296, 0.0871, 0.0296], [0.0296, 0.0296, 0.0871]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.5382333, 0.1839333, 0.1839333], [0.1839333, 0.5382333, 0.1839333], [0.1839333, 0.1839333, 0.5382333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[8.6745, -3.8842, -3.8842], [-3.8842, 8.6745, -3.8842], [-3.8842, -3.8842, 8.6745]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 960.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "5c14e22a-39e2-4cbb-9aec-056684ef40fa", "name": "padswitch_1_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 165.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "b97451c9-daac-45bb-a300-842ddcc87c76", "name": "padswitch_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 151.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "71edde96-3e63-4b16-8a12-0f7c3c2771f1", "name": "padswitch_1_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 301.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "6b25b103-d37c-42ce-9c2a-4fed44a4146e", "name": "padswitch_1_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 205.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "b8abe50a-d021-449e-a17c-f73c1142aee4", "name": "padswitch_3_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.499563, -0.1093613, -0.1093613], [-0.1093613, 3.499563, -0.1093613], [-0.1093613, -0.1093613, 3.499563]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 295.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "140f67fe-0cf8-45a3-8e1d-7cd225dab6f1", "name": "padswitch_3_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.499563, -0.1093613, -0.1093613], [-0.1093613, 3.499563, -0.1093613], [-0.1093613, -0.1093613, 3.499563]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 325.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "6ef66588-c56f-4ab4-8152-a7ceffd19280", "name": "padswitch_3_8", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.499563, -0.1093613, -0.1093613], [-0.1093613, 3.499563, -0.1093613], [-0.1093613, -0.1093613, 3.499563]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 233.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "e6fb8431-c064-4a3e-8d04-97f3fe67c4bb", "name": "padswitch_3_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.499563, -0.1093613, -0.1093613], [-0.1093613, 3.499563, -0.1093613], [-0.1093613, -0.1093613, 3.499563]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 205.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "bb659552-de29-4980-948f-b0934dad487c", "name": "fuse_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 325.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "7428d9ad-6003-41e1-acc5-c6e01cb8cae2", "name": "fuse_1_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 165.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "dc9b42df-2b7f-4193-8152-ae871c971371", "name": "fuse_1_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "a0d4e32b-8224-4708-b512-715f8a126cff", "name": "fuse_1_6", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 295.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "1afe4efd-d8e8-446b-970c-e6ba75da4e22", "name": "fuse_1_9", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 233.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "0fcbf486-ed39-4481-96a7-243f013e9f46", "name": "padswitch_1_4", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "b8590a64-3624-43d1-8279-40a7928d98a9", "name": "padswitch_3_6", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.499563, -0.1093613, -0.1093613], [-0.1093613, 3.499563, -0.1093613], [-0.1093613, -0.1093613, 3.499563]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "1cf20eb0-ac1f-4a6f-882e-a5d94dfb8dcb", "name": "padswitch_3_9", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.499563, -0.1093613, -0.1093613], [-0.1093613, 3.499563, -0.1093613], [-0.1093613, -0.1093613, 3.499563]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 301.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "bf5bc40f-4332-47bf-baf6-f15771c7e420", "name": "padswitch_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.499563, -0.1093613, -0.1093613], [-0.1093613, 3.499563, -0.1093613], [-0.1093613, -0.1093613, 3.499563]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 370.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "39499f7e-f729-4218-afda-ccccc72332f9", "name": "fuse_1_5", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 370.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b", "name": "3p_ug_al_3_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.445, 0.1745, 0.1745], [0.1745, 0.445, 0.1745], [0.1745, 0.1745, 0.445]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.5326, 0.2912, 0.2912], [0.2912, 0.5326, 0.2912], [0.2912, 0.2912, 0.5326]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[145.291, -72.088, -72.088], [-72.088, 145.291, -72.088], [-72.088, -72.088, 145.291]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 285.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "e7b097f2-bcb0-4abe-b9b3-be9ec78c74f4", "name": "", "__metadata__": {"fields": {"module": "gdm.distribution.curve", "type": "TimeCurrentCurve", "serialized_type": "base"}}, "curve_x": {"value": [2.0, 2.1, 3.0, 4.0, 6.0, 22.0, 50.0], "units": "ampere", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Current", "serialized_type": "quantity"}}}, "curve_y": {"value": [300.0, 100.0, 10.1, 4.0, 1.4, 0.1, 0.02], "units": "second", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Time", "serialized_type": "quantity"}}}}, {"uuid": "d467095a-575e-4fb7-991f-4e2cdf643318", "name": "56320575-cdcc-4544-a3e7-3bcae477af01", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 325.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}, "delay": {"value": 0.0, "units": "second", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Time", "serialized_type": "quantity"}}}, "tcc_curve": {"__metadata__": {"fields": {"module": "gdm.distribution.curve", "type": "TimeCurrentCurve", "serialized_type": "composed_component", "uuid": "e7b097f2-bcb0-4abe-b9b3-be9ec78c74f4"}}}}, {"uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770", "name": "f7b2bfa1-8c77-4b62-850d-04620d3799e4", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 165.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}, "delay": {"value": 0.0, "units": "second", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Time", "serialized_type": "quantity"}}}, "tcc_curve": {"__metadata__": {"fields": {"module": "gdm.distribution.curve", "type": "TimeCurrentCurve", "serialized_type": "composed_component", "uuid": "e7b097f2-bcb0-4abe-b9b3-be9ec78c74f4"}}}}, {"uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482", "name": "fb7f7907-38db-42f7-a652-427c0c9d518c", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}, "delay": {"value": 0.0, "units": "second", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Time", "serialized_type": "quantity"}}}, "tcc_curve": {"__metadata__": {"fields": {"module": "gdm.distribution.curve", "type": "TimeCurrentCurve", "serialized_type": "composed_component", "uuid": "e7b097f2-bcb0-4abe-b9b3-be9ec78c74f4"}}}}, {"uuid": "861d64ae-aba6-4135-a3ca-f177438722a2", "name": "c44effc4-af4a-4a90-ba5f-b9ab992a2b0c", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 295.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}, "delay": {"value": 0.0, "units": "second", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Time", "serialized_type": "quantity"}}}, "tcc_curve": {"__metadata__": {"fields": {"module": "gdm.distribution.curve", "type": "TimeCurrentCurve", "serialized_type": "composed_component", "uuid": "e7b097f2-bcb0-4abe-b9b3-be9ec78c74f4"}}}}, {"uuid": "ab93cbf0-52fd-4d3d-a7f9-fd7cb4376fa6", "name": "291ce2f8-f492-4cb6-8b07-5df217ca3f92", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 233.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}, "delay": {"value": 0.0, "units": "second", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Time", "serialized_type": "quantity"}}}, "tcc_curve": {"__metadata__": {"fields": {"module": "gdm.distribution.curve", "type": "TimeCurrentCurve", "serialized_type": "composed_component", "uuid": "e7b097f2-bcb0-4abe-b9b3-be9ec78c74f4"}}}}, {"uuid": "73f75b89-55b4-4a16-9fa1-8771daf3d5be", "name": "8d08090f-ee79-4f79-9907-9e6c53c590a3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 370.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveCurrent", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}, "delay": {"value": 0.0, "units": "second", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Time", "serialized_type": "quantity"}}}, "tcc_curve": {"__metadata__": {"fields": {"module": "gdm.distribution.curve", "type": "TimeCurrentCurve", "serialized_type": "composed_component", "uuid": "e7b097f2-bcb0-4abe-b9b3-be9ec78c74f4"}}}}, {"uuid": "29ee0e2a-8445-4b4f-89fe-d9e9555d89de", "name": "sb10_p1rhs7_1247_311", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30052484-94f2-43a3-abb7-9314d4593c20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ed5e3889-e8c8-4215-adb8-9880f8937da5"}}}], "length": {"value": 0.001511744, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "42f228c5-d3cc-4ea7-9d1c-029acf33213c"}}}}, {"uuid": "bac6250f-86a5-4f43-ac97-3014374e1458", "name": "sb10_p1rhs7_1247_313", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23779a0d-9859-4591-b4ce-7ec704401d42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1548dd91-bc3d-4a2c-903f-48e11159c558"}}}], "length": {"value": 0.001511744, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "42f228c5-d3cc-4ea7-9d1c-029acf33213c"}}}}, {"uuid": "fdee7cd2-4531-4679-9430-6cddbb1eda85", "name": "sb10_p1rhs7_1247_310", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4d9a6e8-eb1b-454c-ae94-2eb435218fb9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14208aa5-3197-4c90-adf9-3067dae9b5f9"}}}], "length": {"value": 0.002267616, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "42f228c5-d3cc-4ea7-9d1c-029acf33213c"}}}}, {"uuid": "516b4490-8d2f-4ed7-8c42-cc189f1caec0", "name": "sb10_p1rhs7_1247_312", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2427b8de-af1a-44f8-9774-724e635057fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec7726f8-0afb-4c35-8a1b-0691a8fb400d"}}}], "length": {"value": 0.002267616, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "42f228c5-d3cc-4ea7-9d1c-029acf33213c"}}}}, {"uuid": "acbd5efd-6ad5-4648-8703-0efb1a4b5dd9", "name": "sb10_p1rhs7_1247_354", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "001adbd4-6616-4dce-83d2-025e896ada51"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3856ea8d-83da-4d2e-8f66-fae6c69b5db1"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "d17ac250-39de-4755-ab93-d93c9ffec1f4"}}}}, {"uuid": "2e5e0aa8-9e09-438d-b554-36c2e72760e7", "name": "sb10_p1rhs7_1247_307", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c975b603-30a6-4ed1-bbae-696d1c5b0a3d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23779a0d-9859-4591-b4ce-7ec704401d42"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "d17ac250-39de-4755-ab93-d93c9ffec1f4"}}}}, {"uuid": "5ce19f15-a792-442e-a7fa-fac766595642", "name": "sb10_p1rhs7_1247_305", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6263cae0-e97a-4044-a130-e971a626d3c1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30052484-94f2-43a3-abb7-9314d4593c20"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "d17ac250-39de-4755-ab93-d93c9ffec1f4"}}}}, {"uuid": "7c2d9b1a-6e34-47c2-acf6-91b80aa94d66", "name": "sb10_p1rhs7_1247_303", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3856ea8d-83da-4d2e-8f66-fae6c69b5db1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c975b603-30a6-4ed1-bbae-696d1c5b0a3d"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "d17ac250-39de-4755-ab93-d93c9ffec1f4"}}}}, {"uuid": "069db73a-656d-42e0-906b-02395eb7257b", "name": "sb10_p1rhs7_1247_347", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16bb904e-b153-4b0a-97f5-53ad7c6606d8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ca7962b4-686c-4bee-af8d-f1851b835adb"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "33fd2b05-630e-42ac-9ccf-60a8ee3f45c9"}}}}, {"uuid": "a60ebb51-1b37-43c3-859c-de42675fe34f", "name": "sb10_p1rhs7_1247_306", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c975b603-30a6-4ed1-bbae-696d1c5b0a3d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2427b8de-af1a-44f8-9774-724e635057fb"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "d17ac250-39de-4755-ab93-d93c9ffec1f4"}}}}, {"uuid": "ffaf79ca-5c18-46fc-b1af-dc55f22795b8", "name": "sb10_p1rhs7_1247_304", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6263cae0-e97a-4044-a130-e971a626d3c1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4d9a6e8-eb1b-454c-ae94-2eb435218fb9"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "d17ac250-39de-4755-ab93-d93c9ffec1f4"}}}}, {"uuid": "a2e353c7-8d1a-4863-a935-f26557420635", "name": "sb10_p1rhs7_1247_349", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ca7962b4-686c-4bee-af8d-f1851b835adb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "574ab810-c1b0-4662-8c4d-f32ab6893a36"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "33fd2b05-630e-42ac-9ccf-60a8ee3f45c9"}}}}, {"uuid": "ecd0c793-0eab-4a56-992b-f4cdf28c9fb5", "name": "sb10_p1rhs7_1247_302", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3856ea8d-83da-4d2e-8f66-fae6c69b5db1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6263cae0-e97a-4044-a130-e971a626d3c1"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "d17ac250-39de-4755-ab93-d93c9ffec1f4"}}}}, {"uuid": "a596de2d-c583-495c-8e87-684ff992d13b", "name": "l(r:p1rdt4964lv-p1rlv10170)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3541a1a-9680-4baf-9b87-a1322cb1a16a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02e86824-b793-4080-9401-c6995a365baf"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "9679fe35-fbbc-45a3-973d-24b473884602", "name": "l(r:p1rdt4980lv-p1rlv10189)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab731358-e17f-4c48-b6f8-c7bb4c7701de"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58f2b2c3-4f6f-4fd2-abb9-42ff665692bd"}}}], "length": {"value": 0.0491385, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ba04e182-afcb-48fa-9746-2e11559cb473", "name": "l(r:p1rdt4980lv-p1rlv10574)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab731358-e17f-4c48-b6f8-c7bb4c7701de"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b4caeee-6304-4a25-a7d8-44c6014b5e37"}}}], "length": {"value": 0.0298046, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "228b5f7b-dac5-4b0e-b0b1-3a389c3dc040", "name": "l(r:p1rdt4980lv-p1rlv10596)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab731358-e17f-4c48-b6f8-c7bb4c7701de"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aad9ea92-9403-4ac0-9aaf-7e845b8c7bb5"}}}], "length": {"value": 0.0197463, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6c6b3bb5-9c25-4716-a167-aace2b875e2e", "name": "l(r:p1rdt5017lv-p1rlv10262)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0375d197-ccd2-4ed8-9439-857b700cefb8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3317d7c2-2588-426d-91fc-3d765b932da6"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "e4d5b6e9-1c05-4376-8081-8308282a46d2", "name": "l(r:p1rdt5126lv-p1rlv10491)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e33e473-8d5b-4704-bdab-56032991f94e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f7116b9-96c1-42c8-850f-7787f5fd0f96"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "fbef4d18-a197-429d-828d-09390792d6c2", "name": "l(r:p1rdm10619-p1rlv10521)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd4b469b-001b-4914-8e51-e98fe3f6babb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31f26b28-fc9d-4b3d-b204-cf40f3478c44"}}}], "length": {"value": 0.0680764, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "148f5acc-b8c0-4d21-a617-7244a63c718e", "name": "l(r:p1rdm10620-p1rlv10641)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e28a5f3a-4447-469a-85dd-e232d8c6d728"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73ada6ad-ace7-46c1-80f7-2cb33cf4cdb3"}}}], "length": {"value": 0.03407530000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "45d46b87-bb36-48a2-8d53-0a55675034bf", "name": "l(r:p1rdm10619-p1rdm10620)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd4b469b-001b-4914-8e51-e98fe3f6babb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e28a5f3a-4447-469a-85dd-e232d8c6d728"}}}], "length": {"value": 0.0178464, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f38d4a07-13c3-4b95-ae7c-7c6b7d041360", "name": "l(r:p1rdm10619-p1rdt5140lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f114a56-98d7-4fe8-b0b1-b8c4bc791cf9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd4b469b-001b-4914-8e51-e98fe3f6babb"}}}], "length": {"value": 0.0178464, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "2d347746-0969-4a8a-b986-c40ef4f4c015"}}}}, {"uuid": "d351709b-972b-4d55-8d6e-f82dce2d848d", "name": "l(r:p1rdm10621-p1rlv20071)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e09d217e-44a5-4013-8d48-8546d6bb1dc3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07f95ba5-92dd-465f-a38d-8e878243262b"}}}], "length": {"value": 0.0125414, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6b760518-573f-4b9d-a363-83b3bb356359", "name": "l(r:p1rdm10621-p1rdt5140lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f114a56-98d7-4fe8-b0b1-b8c4bc791cf9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e09d217e-44a5-4013-8d48-8546d6bb1dc3"}}}], "length": {"value": 0.0178464, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ec0ee5c6-d17f-48f6-bfe3-c14274d5bfb6", "name": "l(r:p1rdt5142lv-p1rlv10523)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e071635-4071-470d-be09-4484cb90441a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35d47036-a044-4c67-b5b5-0006e2a3b68e"}}}], "length": {"value": 0.019072, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8bc645f7-1f0e-434d-bacc-53e73e4258fe", "name": "l(r:p1rdt5142lv-p1rlv10616)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e071635-4071-470d-be09-4484cb90441a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a5717e0-080e-46ae-918a-64fe4fcba5d7"}}}], "length": {"value": 0.019072, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "587cec7d-7000-4cf3-9010-3f39f71a3747", "name": "l(r:p1rdt5153lv-p1rlv10538)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ec20ad2-b04f-43fc-ad8d-d41746549a57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a302271d-4cf3-45ff-9308-b9cf31fbefa3"}}}], "length": {"value": 0.052564700000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "ebfd9db5-3ac9-4827-98f7-d190caca7cdf", "name": "l(r:p1rdt5153lv-p1rlv10586)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ec20ad2-b04f-43fc-ad8d-d41746549a57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfbe5665-c020-455a-addc-d3f9514735ed"}}}], "length": {"value": 0.0379881, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "d76eb6de-93b6-410f-955e-c8305a62dbe6", "name": "l(r:p1rdt5153lv-p1rlv10610)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ec20ad2-b04f-43fc-ad8d-d41746549a57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b91354e-ce50-44d0-a959-fa451bb9cf20"}}}], "length": {"value": 0.0253548, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "7f0e2518-b943-445a-b36b-df23de1add14", "name": "l(r:p1rdt5155lv-p1rlv10540)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85351f49-cb19-4f71-a6ae-a21f5a48af6f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4829cd2f-7e61-4386-89ce-89d77d5ef5cf"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "5e07c049-b3d7-4d1a-9c10-f0144ef0ecfe", "name": "l(r:p1rdt5159lv-p1rlv10544)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba7e3a6b-f62f-432f-afe7-2ebbfc9abd59"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c722b89-fdaf-416f-863e-02b443375ba1"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "082ef98e-736d-4b9d-8761-8e1f28430622", "name": "l(r:p1rdt5172lv-p1rlv10563)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48efdcb9-083c-4e17-a1d2-acb1388f085e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8a10822-398f-441e-a5ca-73303d832183"}}}], "length": {"value": 0.0709049, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "de3f7150-cc4b-4cdd-8586-d90b3e9f0791", "name": "l(r:p1rdt5179lv-p1rlv10573)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd4155b2-ca55-41d7-bd35-98a5eec8c39a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94677ede-fd5c-4fbb-bfcd-98cf67b56913"}}}], "length": {"value": 0.0550518, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3957c039-612c-45ec-869b-4310f9d481bb", "name": "l(r:p1rdt5179lv-p1rlv10583)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd4155b2-ca55-41d7-bd35-98a5eec8c39a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0431d17-75da-48c1-965c-875f61b0e9bf"}}}], "length": {"value": 0.0550518, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0997b3ce-c275-4e58-aafb-272b62d6c6b6", "name": "l(r:p1rdt5180lv-p1rlv10576)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae26acb3-c2c9-479c-9d19-c30bf00aa8c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25141e20-0a65-4905-b37f-954ed1a8751c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "e5f30957-f466-42ef-b23f-40321acb3168", "name": "l(r:p1rdt5183lv-p1rlv10582)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bbde2e8-42c0-486b-9759-78898d177f93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdfa726f-5606-4ae2-b358-ad664dd7b0e3"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b6b313aa-24d6-40ba-afd6-6230958c1568", "name": "l(r:p1rdt5184lv-p1rlv10589)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1656cc28-8a5b-40da-887f-25605dd336aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53019a8a-b453-4add-9d2d-e4ab380fce67"}}}], "length": {"value": 0.0161579, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "55582f95-1e69-4d6b-b0db-f4b4992538e3", "name": "l(r:p1rdt5184lv-p1rlv10600)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1656cc28-8a5b-40da-887f-25605dd336aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "feb19590-c5f4-4982-9e99-20599f08cfe7"}}}], "length": {"value": 0.0127667, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "87f828d3-1f6d-403b-852d-3f8e3c7b7b65", "name": "l(r:p1rdt5184lv-p1rlv10621)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1656cc28-8a5b-40da-887f-25605dd336aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "374d5417-b2c4-4d16-9b91-d2f519921fd8"}}}], "length": {"value": 0.0240219, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3b197939-0e9a-4bb2-97a0-2ba01199fb47", "name": "l(r:p1rdt5195lv-p1rlv10615)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf05c1bb-39cc-48b3-a576-18913e0cff13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b175fcb-d1ee-44eb-8f89-826e40c5db1d"}}}], "length": {"value": 0.00593856, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9cd169ad-8154-4e21-addc-d48efa048977", "name": "l(r:p1rdt5195lv-p1rlv10634)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf05c1bb-39cc-48b3-a576-18913e0cff13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3184f056-3b5f-403d-86a0-f9b28d6bb3e3"}}}], "length": {"value": 0.018580700000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d25b1b60-f739-427b-bb68-d15d2a530266", "name": "l(r:p1rdt5200lv-p1rlv10627)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "03e7bfdb-ff8b-4142-95ef-8d848ff5d2db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32406d7d-51f9-4c16-900b-526985e5f62b"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "1695160c-d7a9-4b56-a36a-9bf4c210266e", "name": "l(r:p1rdt5201lv-p1rlv10629)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8162a8c-5339-4f42-bd7a-b6dbc5ff463b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e183b3e8-d995-4f1e-baee-8d9d4add157e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "91226eb3-4986-4099-afcc-ba8a616753bc", "name": "l(r:p1rdt5202lv-p1rlv10630)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "39eaedd7-75b6-449f-8ff6-6e31f6e74504"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d60a935-dc9b-48ea-8ee7-9b682452035e"}}}], "length": {"value": 0.0271144, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4ab0b458-002d-4941-8fb5-8fa003f96669", "name": "l(r:p1rdt5206lv-p1rlv10637)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "599a2995-33d5-4bcc-8cd3-585ea37577cd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9510bd0-2bba-4522-bfbe-20b94ea400b6"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "24998fa4-29c5-43de-8a56-451bf7088b34", "name": "l(r:p1rdt5218lv-p1rlv10663)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c650eda9-132b-4419-a055-ad68037c7772"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8198c1c5-67e0-49b9-b11a-1f266f7f4bcb"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "4f0bce0b-cec8-4270-90da-19caf6b4f966", "name": "l(r:p1rdt5236lv-p1rlv10720)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f252d81-66ee-40a6-bce7-2891e06b39e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3d48c0e-704d-4205-94a2-ee74be7ae350"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "52f0d3a1-455d-4799-a4f4-b36bd83a3789", "name": "l(r:p1rdt5342lv-p1rlv10955)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e01069aa-388b-4362-9d02-a164f173dc20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75dbf8f0-4cb6-49b7-a2a5-f98e9ff4b8df"}}}], "length": {"value": 0.017914800000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8823cd6f-545e-4acd-bd12-eea1e38174b4", "name": "l(r:p1rdt5342lv-p1rlv11048)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e01069aa-388b-4362-9d02-a164f173dc20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a8fc823-6fe8-4a3b-9437-68aa751f5e3b"}}}], "length": {"value": 0.017914800000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d01caf79-b234-437a-9476-0490ec03d12d", "name": "l(r:p1rdt5472lv-p1rlv11380)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34a1276e-c702-4c69-b7b1-566d400da2de"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f949a06a-817e-4666-95bb-9536ce06a694"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b63446ac-e79f-48cf-b564-dee1da12a798", "name": "l(r:p1rdt5475lv-p1rlv11384)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d181674-9355-488b-8a3f-5b7c844c35a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0c23aea-471f-4d10-9500-1bc14a67d7e7"}}}], "length": {"value": 0.0318484, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "07dc8977-0ddc-41bf-98a9-8dfec5f9d3b4", "name": "l(r:p1rdt5475lv-p1rlv11386)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d181674-9355-488b-8a3f-5b7c844c35a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f512d86-c9d9-4f58-9d5a-418d0732dc94"}}}], "length": {"value": 0.008446400000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9d9f36bf-d24f-4ab2-a186-fcf4cf92cb27", "name": "l(r:p1rdt5475lv-p1rlv11397)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d181674-9355-488b-8a3f-5b7c844c35a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fd316b0-fd98-4193-9c1b-aaa7d92a4284"}}}], "length": {"value": 0.0375424, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f8c8391e-0f26-45c6-aa81-d7d2ebd35f26", "name": "l(r:p1rdt5476lv-p1rlv11385)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0888f4c5-e037-4891-99fb-fd43934ffae0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2115e8bb-fe49-49ad-8687-68feca212557"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "54f88b11-22f1-4b51-9851-8a348fa7f66b", "name": "l(r:p1rdt5477lv-p1rlv11387)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fafd64c3-efe5-4684-b06f-44e4c8555aa4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbca8c57-0da4-4368-9821-7a9ca4282173"}}}], "length": {"value": 0.0726843, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4ecd7eab-ac7e-4a24-ac86-8a3f9931e089", "name": "l(r:p1rdt5478lv-p1rlv11388)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5107bc9c-f463-49f6-a92f-23c5730475e2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12377bf0-f258-4c29-ab26-e938c95ee25c"}}}], "length": {"value": 0.0557394, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "38a0fb7e-0479-4716-ad92-ef062f819e5b", "name": "l(r:p1rdt5478lv-p1rlv11398)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5107bc9c-f463-49f6-a92f-23c5730475e2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97aa01fe-2e60-4617-8c89-d36f425087fe"}}}], "length": {"value": 0.0557394, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b3073021-9bde-4166-9c27-e2551b7120aa", "name": "l(r:p1rdm11569-p1rlv11390)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "004f56b2-ec94-4189-91b8-46b4af22faa6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b6420b1-3456-42fc-9266-c2b84e063cec"}}}], "length": {"value": 0.110315, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "de9801d0-ebc2-474b-85f2-d670474b0d18", "name": "l(r:p1rdm11569-p1rdt5480lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44ac9e38-8ae3-4102-822b-1c638a6c878a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "004f56b2-ec94-4189-91b8-46b4af22faa6"}}}], "length": {"value": 0.0194577, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "be1cb5ab-a890-4c9b-8c5d-ca7990b7fa8b", "name": "l(r:p1rdm11570-p1rlv11401)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8be902f6-4cca-4ce5-9f73-a1f96c65d8ef"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a215d7dd-8081-4355-9c38-4fd3d2c859c7"}}}], "length": {"value": 0.0577794, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c8464817-2597-4ffb-9d58-991b40d0d49f", "name": "l(r:p1rdm11570-p1rdt5480lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44ac9e38-8ae3-4102-822b-1c638a6c878a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8be902f6-4cca-4ce5-9f73-a1f96c65d8ef"}}}], "length": {"value": 0.0194641, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "878ec4a9-cef2-42e8-8ff1-768ea4ee08b7", "name": "l(r:p1rdt5481lv-p1rlv11392)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f213ee9e-6ae7-4e82-9f25-6fc456f45576"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e740a352-ac8f-4ae2-ace3-254fccd7f96f"}}}], "length": {"value": 0.00971421, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "27b93701-b086-409f-b6c4-248ad3a79eab", "name": "l(r:p1rdt5481lv-p1rlv11394)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f213ee9e-6ae7-4e82-9f25-6fc456f45576"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "996d3e44-142c-42fa-bf4f-2bd1777122dd"}}}], "length": {"value": 0.00971421, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d927f88c-f87d-4609-b7d9-3b440a8942a8", "name": "l(r:p1rdt5483lv-p1rlv11395)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a73d544-9f33-49d9-b648-c806addf3c06"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29922f55-f36a-4b9e-8836-5f9dadd641b7"}}}], "length": {"value": 0.0408239, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b45fdc13-573f-4d62-8969-6d807aee8b95", "name": "l(r:p1rdt5485lv-p1rlv11399)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40eaefce-482f-4a89-bec1-2c11bac2bfb7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68a9eead-8197-4e82-a444-2a4544ec9ddb"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "400b640e-346e-4663-9421-ff28dce9686e", "name": "l(r:p1rdt5650lv-p1rlv11671)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28a6e44b-c6c7-4556-b4d8-d55359391c66"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "834a5733-5264-4adf-861a-25e494df3e37"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "2f30c2bf-be3e-4b60-a6e7-231231e94831", "name": "l(r:p1rdt5653lv-p1rlv11674)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38d1de19-1f51-4875-acc2-a75e3d1a290e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "45f2a901-e4f7-4055-a3e2-b60c61d5033e"}}}], "length": {"value": 0.0467126, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f1e52a68-1c9c-4651-b590-c66946bb5bd9", "name": "l(r:p1rdt5656lv-p1rlv11677)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "87e8c57e-67ff-439c-b28b-0fbdbfd62ea6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b2f121a-2202-43c0-8684-81913a5d6ea9"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "cd9590d2-b2ef-45a1-a2a0-7879503ae2da", "name": "l(r:p1rdt5662lv-p1rlv11684)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea73a91a-b052-486e-810b-1a5ad281e07b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02aef971-5f4a-4ca8-aa33-cce34517bd44"}}}], "length": {"value": 0.0429078, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0d0ec938-717a-4694-87b7-c4ffcc8becc4", "name": "l(r:p1rdt5663lv-p1rlv11686)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16a67a88-5d11-4eca-85fe-38c948ad362c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cda8e361-98b6-49bd-a3ff-30a036a3dc6f"}}}], "length": {"value": 0.0119369, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e9a6d297-511a-4374-baa4-5957c5a9660a", "name": "l(r:p1rdm11909-p1rlv15645)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5b71ca5-a7ab-42f7-824a-bc43fc1708cc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "449098c3-4f65-4350-863f-4b7bc1f14493"}}}], "length": {"value": 0.043632500000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1ac2f810-c321-44b7-95e4-0c2294035bca", "name": "l(r:p1rdm11909-p1rdt5663lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16a67a88-5d11-4eca-85fe-38c948ad362c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5b71ca5-a7ab-42f7-824a-bc43fc1708cc"}}}], "length": {"value": 0.0154548, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "367b85dd-74f1-4252-bf45-811d7899bfaa", "name": "l(r:p1rdt5728lv-p1rlv11779)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6d456893-4d89-455a-b1a5-4863aad6293a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0ba1408-17da-4678-8b04-90c616c3fb48"}}}], "length": {"value": 0.0661386, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "fadcfd18-1437-4d57-ae07-5feb2b125a65", "name": "l(r:p1rdt5728lv-p1rlv11783)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6d456893-4d89-455a-b1a5-4863aad6293a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3890375-c01d-44d2-93f9-8d9d60da8852"}}}], "length": {"value": 0.0661386, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f3b9d6c3-246a-4d60-9f2a-b29050a691c1", "name": "l(r:p1rdt5729lv-p1rlv11780)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95f81d7a-a6af-4843-bfa1-002abc7ff870"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e9a574d-9537-417a-a811-e22d84b8ea53"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b41f8809-5b99-439f-9bd6-a6fc8cb47c7c", "name": "l(r:p1rdt5730lv-p1rlv11784)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2dd206bc-965d-46c9-8fdb-8c158c7bba05"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b66df0bc-6159-42fa-bf49-b8ad17d0e6aa"}}}], "length": {"value": 0.0506895, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2c42071d-569c-4f35-8d65-90380f97501d", "name": "l(r:p1rdt5730lv-p1rlv11786)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2dd206bc-965d-46c9-8fdb-8c158c7bba05"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b15fc66-89d9-483b-9c9f-9b0f39a63b29"}}}], "length": {"value": 0.024148300000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2b57623a-601b-4dbd-bc38-661889b37a6b", "name": "l(r:p1rdm12071-p1rlv11781)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64ee7f4c-b91a-4a25-b85d-a91b83777c1f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28fd9f7c-0195-4529-a972-aa60eced47d2"}}}], "length": {"value": 0.0191276, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3d9ddc49-14e7-4dd7-a2c5-d98beb0d3444", "name": "l(r:p1rdm12071-p1rdt5730lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2dd206bc-965d-46c9-8fdb-8c158c7bba05"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64ee7f4c-b91a-4a25-b85d-a91b83777c1f"}}}], "length": {"value": 0.0173818, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8b230ec6-5ef9-47a7-990c-fafb6e26a6c3", "name": "l(r:p1rdt5731lv-p1rlv11782)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e414162-eda7-4cf2-9116-fc24af9461bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "496fc854-bbf8-463b-b16c-12dd1b444cc6"}}}], "length": {"value": 0.0292119, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a73dcae4-6fc0-4b6f-a432-3cb5ef33058b", "name": "l(r:p1rdm12075-p1rlv11785)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7103c2f0-8160-434f-b4b3-edfbd7e97464"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ed0eb774-fcc3-417f-a8a4-fbdb825cc106"}}}], "length": {"value": 0.0190573, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d6dbe381-462c-408e-87b7-e82db0872b88", "name": "l(r:p1rdm12075-p1rdt5731lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e414162-eda7-4cf2-9116-fc24af9461bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7103c2f0-8160-434f-b4b3-edfbd7e97464"}}}], "length": {"value": 0.0194685, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "40793b09-be51-4c19-855d-a9cab1a29975", "name": "l(r:p1rdt5840lv-p1rlv12028)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9974869d-7d87-4a27-9606-076cd7799953"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1dfd848-b639-41b5-ad95-2c03a51bd36b"}}}], "length": {"value": 0.0166971, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "59eddbe0-cc88-4acf-aab0-ee9589891212", "name": "l(r:p1rdt5840lv-p1rlv12157)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9974869d-7d87-4a27-9606-076cd7799953"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc4d79bb-8ba3-4146-9d50-16db48ffec22"}}}], "length": {"value": 0.0166971, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "80b0ac16-51ce-4b22-8d60-68d9d40dc483", "name": "l(r:p1rdt5923lv-p1rlv12214)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "751d2f2e-bb6f-4ca6-9e86-0e2b5ff3f92a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df9d9de2-6929-48a4-a390-c0e2f129b374"}}}], "length": {"value": 0.0436747, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "55166bbd-4d92-45f6-90c8-7e525148435b", "name": "l(r:p1rdt5923lv-p1rlv12217)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "751d2f2e-bb6f-4ca6-9e86-0e2b5ff3f92a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4d26673-c304-41de-8b5b-149552601ba4"}}}], "length": {"value": 0.0140011, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8cba7cbc-61c9-40c7-a472-15ba57ed7cc2", "name": "l(r:p1rdt5923lv-p1rlv12222)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "751d2f2e-bb6f-4ca6-9e86-0e2b5ff3f92a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cee79fe8-f140-4be9-aa6b-d56e37fb6857"}}}], "length": {"value": 0.06246270000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d23744d0-51a4-42f6-a714-7ca8bc4f452a", "name": "l(r:p1rdt5923lv-p1rlv12225)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "751d2f2e-bb6f-4ca6-9e86-0e2b5ff3f92a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8e1f797-9417-447c-8a08-cf00a462ef14"}}}], "length": {"value": 0.0351977, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "5163b09b-32f5-4b89-8d37-f90900ee57a4", "name": "l(r:p1rdt6038lv-p1rlv12538)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d654945d-b71d-4943-86a2-5830fca200c9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b42c2471-9114-4042-980e-dd226ad024a3"}}}], "length": {"value": 0.010266900000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "804e6cda-09e4-439b-b278-de2464a271a4", "name": "l(r:p1rdt6043lv-p1rlv12552)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ae7bbf-f53e-4ae2-8145-bf56ce935094"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c42d772-e2a8-45d4-9cf2-2edd7a567b35"}}}], "length": {"value": 0.0181528, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "b31deec8-a68b-4572-a9fa-62a1124c070a", "name": "l(r:p1rdm12875-p1rlv12553)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3e53a11-6c13-4d27-89f2-2abbd28f69ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a29aec49-62a4-41ec-a67c-a84470a23f7b"}}}], "length": {"value": 0.0385577, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "5ee09bf3-d8ba-4f9e-ae22-905ffbba3cfa", "name": "l(r:p1rdm12875-p1rdt6043lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ae7bbf-f53e-4ae2-8145-bf56ce935094"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3e53a11-6c13-4d27-89f2-2abbd28f69ac"}}}], "length": {"value": 0.0560413, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "d6a45977-5d4a-4d99-a466-58bc7bf18e45", "name": "l(r:p1rdm12876-p1rlv12559)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b748c697-b624-43f0-b375-5024d8cff92b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a47101-b6df-473e-9c7b-96e076c17931"}}}], "length": {"value": 0.0120531, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "09aeebd8-f06b-4d31-bf4d-0e7a60792681", "name": "l(r:p1rdm12877-p1rlv12562)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3082eb6b-1a9f-4b6e-930e-f58173fe02ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b0417d3-820d-4daa-aec5-3dcf34e40e00"}}}], "length": {"value": 0.00937768, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "d8bd73cc-9912-47ad-abdb-98e0f3860f40", "name": "l(r:p1rdm12876-p1rdm12877)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b748c697-b624-43f0-b375-5024d8cff92b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3082eb6b-1a9f-4b6e-930e-f58173fe02ac"}}}], "length": {"value": 0.00528266, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "7b24a598-5dca-4ef9-a2fb-eb6cd38fc84c", "name": "l(r:p1rdm12876-p1rdt6043lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ae7bbf-f53e-4ae2-8145-bf56ce935094"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b748c697-b624-43f0-b375-5024d8cff92b"}}}], "length": {"value": 0.0304331, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "388119d6-f740-4a34-b677-297b11d1d4a9", "name": "l(r:p1rdt6046lv-p1rlv12557)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2e2d1a7-039c-4b29-a061-b814ac675e3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fe4d6ae-cca5-476c-981a-a1dcd27b1e84"}}}], "length": {"value": 0.0315499, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "ee6ada67-4f86-4be6-b132-2aad7bf157f5", "name": "l(r:p1rdt6047lv-p1rlv12558)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21e75ccd-7e21-4f0d-890c-81aa6b33b109"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a427f20-861a-4616-9443-265beaeccca3"}}}], "length": {"value": 0.00804165, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "24ad47a8-99be-4c96-9d61-3961533ba7d0", "name": "l(r:p1rdt6208lv-p1rlv12936)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01be483b-09f4-450e-a39d-78692c40ee8b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "019e419c-9f88-455a-bf48-b89531ed9e51"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "3f467e00-f448-4c36-8cb1-d2229235a0d9", "name": "l(r:p1rdt6221lv-p1rlv12959)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73f78740-2ec5-4ad8-b7fb-40f4a72b730e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8418804f-aad5-49df-9916-f427da5089c1"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "fb81f428-e1d6-442c-82a6-cb1c5af44b3c", "name": "l(r:p1rdt6226lv-p1rlv12971)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3154eee7-a1ba-4b9d-9e91-bab55529d358"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be845651-8e1c-4b6d-8633-fcbdfb1fd5d4"}}}], "length": {"value": 0.0550308, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "209ae9db-43f7-4864-9a91-dd599c660b29", "name": "l(r:p1rdt6226lv-p1rlv20185)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3154eee7-a1ba-4b9d-9e91-bab55529d358"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "646058a3-cda7-4723-bd0f-05d305fe7c11"}}}], "length": {"value": 0.0550308, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "baa087fe-f55d-461e-98a8-a7791ca43e18", "name": "l(r:p1rdt6268lv-p1rlv13043)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72ce0706-6b32-4b4b-9bf3-fd1f5a6af5ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3072c6c-3a40-4e49-bd00-febc8268b135"}}}], "length": {"value": 0.038529200000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c319e0c1-2119-4d87-af76-491d2ce8fdec", "name": "l(r:p1rdt6268lv-p1rlv13047)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72ce0706-6b32-4b4b-9bf3-fd1f5a6af5ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4209bdad-276f-4e07-93e0-78b162ce95cf"}}}], "length": {"value": 0.0748394, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "009b3a8c-9e06-4cda-bc24-d2f036ee33a2", "name": "l(r:p1rdt6268lv-p1rlv13054)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72ce0706-6b32-4b4b-9bf3-fd1f5a6af5ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21c6ea4f-ec9d-424e-8743-7175408f9e2c"}}}], "length": {"value": 0.0369069, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a53a4533-5597-4cc6-9369-c1ea467408b4", "name": "l(r:p1rdt6269lv-p1rlv13044)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79c91fa8-15ad-4e8d-96bd-2cad395dd280"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa31c772-8460-4624-a123-64b87ca8d332"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "bc4eed45-5ff4-4307-bb2c-bb2c0189e21a", "name": "l(r:p1rdt6270lv-p1rlv13045)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5adb2083-3d46-48a7-8996-37c0781b0215"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6070414d-09e7-48a7-aec0-c105cc0f1a93"}}}], "length": {"value": 0.034086700000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8b7550b3-6d1b-4305-af43-5cc86d9bf52f", "name": "l(r:p1rdt6270lv-p1rlv13046)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5adb2083-3d46-48a7-8996-37c0781b0215"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5edc15fb-49d5-4052-8fad-4979578f6ed1"}}}], "length": {"value": 0.0160269, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "09abe480-4eaa-43f7-a172-88856f758284"}}}}, {"uuid": "93980ed3-1b22-488f-8670-d1ef74982523", "name": "l(r:p1rdt6270lv-p1rlv13052)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5adb2083-3d46-48a7-8996-37c0781b0215"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86d59550-d7c8-47e1-a6bc-14b2d50de58c"}}}], "length": {"value": 0.04494170000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "786442b2-02c0-49ce-84bc-697eb42f86e0", "name": "l(r:p1rdt6271lv-p1rlv13048)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1335e64c-9f37-4e73-a37f-8f76737cabff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "569078be-37c2-4c05-8455-91945eb7fdb9"}}}], "length": {"value": 0.0901436, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "559c20cc-21df-4271-8c6c-9082c619342d", "name": "l(r:p1rdt6272lv-p1rlv13049)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04422e0a-1952-422d-a201-5fafef1875db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ed85192-4c5a-4c15-ba21-1ba883b03ddd"}}}], "length": {"value": 0.00941805, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f04b5148-7972-4220-8564-2067c13a4eb3", "name": "l(r:p1rdt6272lv-p1rlv13053)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04422e0a-1952-422d-a201-5fafef1875db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e058437-0138-4305-a33e-d8fa61aed8cc"}}}], "length": {"value": 0.00941805, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2f3c609b-2021-408f-8726-e117aee9d249", "name": "l(r:p1rdm13376-p1rlv13051)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b6739c0-1b15-42c1-9fdd-4d7f604a03ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9a855b0-538e-4fab-91f1-93b4ece09409"}}}], "length": {"value": 0.0533824, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1160992a-885e-46ae-b199-876ea6532f62", "name": "l(r:p1rdm13376-p1rdt6274lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1db8c80-e791-4c31-a6f2-713aa665bf41"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b6739c0-1b15-42c1-9fdd-4d7f604a03ce"}}}], "length": {"value": 0.0171039, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f4585475-d917-4176-9105-3c08f98e6ae2", "name": "l(r:p1rdm13377-p1rlv13056)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e395985-4c66-49c9-9252-94d8078b8e8e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16584dfd-537d-4b0d-a651-c73d0beabc6d"}}}], "length": {"value": 0.04504020000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3415f9bf-f574-44ed-b40d-dde7483331f3", "name": "l(r:p1rdm13377-p1rdt6274lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1db8c80-e791-4c31-a6f2-713aa665bf41"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e395985-4c66-49c9-9252-94d8078b8e8e"}}}], "length": {"value": 0.0171039, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7bd303bc-c877-43d3-92ed-7bf8d2e8223a", "name": "l(r:p1rdt6275lv-p1rlv13055)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba567584-fbee-44eb-b3f1-da24a0ce66a0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387df3d3-5f03-47f4-8b16-bea8815e63d1"}}}], "length": {"value": 0.0150884, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ce961dd6-3068-4529-b5b2-7ae148f76be1", "name": "l(r:p1rdt6275lv-p1rlv13058)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba567584-fbee-44eb-b3f1-da24a0ce66a0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c83997dc-872f-494f-8c8a-7266c854fc48"}}}], "length": {"value": 0.0150884, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f7952fba-5181-4715-84ef-6c47236d1571", "name": "l(r:p1rdt6276lv-p1rlv13057)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f20ace2-5ec8-4451-b7e7-66f46c2c487b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c63d163-75bd-4d91-bcfa-229a2e331b1f"}}}], "length": {"value": 0.0435582, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "de4dd982-2e26-43e0-bd9e-d2a4a732efb1", "name": "l(r:p1rdt6276lv-p1rlv13062)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f20ace2-5ec8-4451-b7e7-66f46c2c487b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d2fa164-4c03-4bcd-a386-749ccd4e9001"}}}], "length": {"value": 0.0435582, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "085a1bfb-ff94-46ab-9c2a-9f9baee7d5e7", "name": "l(r:p1rdt6277lv-p1rlv13059)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e582b04d-a8d8-4ee9-8576-1e5941623c0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a1779b5b-1a6c-4511-9d4b-88026b430173"}}}], "length": {"value": 0.00731377, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "87f20977-ad83-4193-8443-34331741b51d", "name": "l(r:p1rdt6278lv-p1rlv13060)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b37eabc-787a-491f-bc4f-956f43a862ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8767a040-da31-48d9-9473-0941856bcedc"}}}], "length": {"value": 0.0214401, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4863f307-9b70-4638-bfb9-09034f350d4b", "name": "l(r:p1rdt6345lv-p1rlv13185)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a38eb6d-a625-42a1-95f6-bbf078d1447a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c29c3206-b71d-41d1-8ad7-a693c8c25d4d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "422ef105-d242-44fb-a517-c36ddd805f83", "name": "l(r:p1rdt6347lv-p1rlv13187)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e40008af-ff50-42bd-8897-f663c27a436f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ffbd17b6-b1a2-4e55-9052-67a84419bb9d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "f4d53aad-8c53-4280-8a58-e354c3deb985", "name": "l(r:p1rdt6348lv-p1rlv13188)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d84ac329-f314-41be-a2ee-89bc74789a18"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67ffcd9f-ba90-4da7-b3b6-46310e321590"}}}], "length": {"value": 0.0371493, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b9f20c71-b16d-49bc-b80b-42f92cd6aded", "name": "l(r:p1rdt6348lv-p1rlv13191)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d84ac329-f314-41be-a2ee-89bc74789a18"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f6d09e9-3592-4560-8626-0d7cb71ca56a"}}}], "length": {"value": 0.0217677, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "99adfcee-ce5d-4d2a-8a1e-e54a38a2c08d", "name": "l(r:p1rdt6348lv-p1rlv13195)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d84ac329-f314-41be-a2ee-89bc74789a18"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e3e10c6-6ce2-4efa-be50-80e8b9bffe29"}}}], "length": {"value": 0.0257734, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3912c661-e4ef-4616-8d05-3299ab44ff9e", "name": "l(r:p1rdt6348lv-p1rlv13201)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d84ac329-f314-41be-a2ee-89bc74789a18"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cdd7c49-e758-4009-8db5-d0b5748f919c"}}}], "length": {"value": 0.008488610000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3c1adb4d-4ff6-4c8a-8c1a-43251f741964", "name": "l(r:p1rdt6349lv-p1rlv13189)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdfa0310-7dc5-4181-a64e-cc2522370547"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "268361f6-d5ac-4002-80a6-f56f3b33599c"}}}], "length": {"value": 0.0123575, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "59797aff-2413-4c30-b02b-f1d86b4483ea", "name": "l(r:p1rdt6350lv-p1rlv13190)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0138b892-d18e-497c-9857-c4d5676deac2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3dbc593c-3949-4fa4-8738-d92540dbf998"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "5cf6510a-4dea-4772-ad91-0ea898f6570e", "name": "l(r:p1rdt6353lv-p1rlv13194)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "015322ae-7712-488f-9569-33fc785e4f62"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d5ba889-d8f7-44ca-86b2-40939fa95df2"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "3c73b898-fe34-4069-b66a-29eddd852722", "name": "l(r:p1rdm13558-p1rlv13196)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fd10fd1-b67f-422c-b976-582e2bb4e0ec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27013147-3d8f-4d75-a7a7-24457dc6d62a"}}}], "length": {"value": 0.0952802, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d43267bf-c60c-46cf-a3c3-40514c8ed391", "name": "l(r:p1rdm13558-p1rdt6354lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f06a08bd-05ea-4914-b0d0-07cd0e83bfbc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fd10fd1-b67f-422c-b976-582e2bb4e0ec"}}}], "length": {"value": 0.019710700000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b6dc79bc-04b3-4a9d-95f9-39133febe09b", "name": "l(r:p1rdm13559-p1rlv13200)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "786efaf4-c281-4def-9a4e-2ffbf37e08be"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fed30a3f-12a5-4545-b5d5-5c13a131a256"}}}], "length": {"value": 0.0781624, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "336fd466-42ce-4a03-a8b1-500c9b6320ff", "name": "l(r:p1rdm13559-p1rdt6354lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f06a08bd-05ea-4914-b0d0-07cd0e83bfbc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "786efaf4-c281-4def-9a4e-2ffbf37e08be"}}}], "length": {"value": 0.0196968, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3fb850f0-48fc-4d93-9b2f-53099e8c7a93", "name": "l(r:p1rdt6355lv-p1rlv13197)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1d14a79-4d18-43fe-8790-57ea9adf83a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b077d0f-74ec-4a04-8eb8-cf02ad16077d"}}}], "length": {"value": 0.00855264, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7445bde4-f85a-4868-beaa-c9eb3c64ae62", "name": "l(r:p1rdt6356lv-p1rlv13199)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "548724aa-110a-428f-b71a-acdf0051dc39"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad7545fb-8a41-4ed7-a178-e90f19bfa9d5"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "1b5cb726-1c52-4df2-8c39-dd309d7acca2", "name": "l(r:p1rdt6409lv-p1rlv13316)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e36cfaaa-3996-4cc6-aa4f-170f20c5d1e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473b080b-1412-40dc-a452-09d43a462098"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "9e896bae-73ca-433f-9ddc-b981c3e73cf1", "name": "l(r:p1rdt6498lv-p1rlv13597)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "353889fb-da44-4cf8-ae0e-d20541f36d7e"}}}], "length": {"value": 0.0114781, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8553403c-d26e-4b50-8608-cd168ebfbd94", "name": "l(r:p1rdt6498lv-p1rlv13631)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6015a810-79da-480f-b1a1-fd6a4abdba37"}}}], "length": {"value": 0.00314293, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "c01c83bb-3dbc-4882-b0f0-e842930869ba", "name": "l(r:p1rdt6498lv-p1rlv13696)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f92273c9-90b8-4819-b036-9d69afb5aed6"}}}], "length": {"value": 0.0270935, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1b049af0-8fb0-40ee-8c70-d2be4bee9165", "name": "l(r:p1rdt6498lv-p1rlv13702)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fe3c958-296f-4b51-8b2b-74bb34ddb5a6"}}}], "length": {"value": 0.0161535, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d15500ac-94ef-479c-a786-fdd84b84b87e", "name": "l(r:p1rdt6498lv-p1rlv13703)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9efacf5-5b96-4670-b6f1-dc398485cde9"}}}], "length": {"value": 0.0105519, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4fc94db9-da62-43ee-9583-c2c0fd98625c", "name": "l(r:p1rdt6498lv-p1rlv13724)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "457c6c9d-5020-4cf3-9c1e-c36012a619d2"}}}], "length": {"value": 0.0187626, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8091ae42-7ca0-4232-911a-682fa9fb74a3", "name": "l(r:p1rdm13996-p1rlv13598)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce39f1f5-b784-4919-9d3d-f6149f39595e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59953c2f-244e-4bb8-ab24-b28d82b195e1"}}}], "length": {"value": 0.0312105, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "01e418b1-0c88-4fa1-9b60-1516e6ba9401", "name": "l(r:p1rdm13996-p1rlv13626)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce39f1f5-b784-4919-9d3d-f6149f39595e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aeea20e0-9908-4f28-aa5d-068244e3861b"}}}], "length": {"value": 0.045519500000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "166332aa-67ba-485f-93b1-02469f1cdf58", "name": "l(r:p1rdm13996-p1rlv13635)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce39f1f5-b784-4919-9d3d-f6149f39595e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc33013a-6a90-46a7-9127-f32288111c14"}}}], "length": {"value": 0.0353648, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2b8702e0-0e6b-4594-a41c-501c6a9f441d", "name": "l(r:p1rdm13996-p1rlv20504)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce39f1f5-b784-4919-9d3d-f6149f39595e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b3e7495-7732-42ce-8d53-a5f1b7383ce4"}}}], "length": {"value": 0.0518247, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f092bdfa-1b2e-4449-91e0-4c62efc169e0", "name": "l(r:p1rdm13996-p1rdt6499lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb05d831-1556-4f56-8065-d9d16657caa3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce39f1f5-b784-4919-9d3d-f6149f39595e"}}}], "length": {"value": 0.0125057, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0581c111-e821-458c-a17c-100b3ff33c3a", "name": "l(r:p1rdm13999-p1rlv13698)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f85240e6-bbbe-4b90-8419-a00a3ca9613f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3839c291-3f45-46c3-973f-6a9615fcf81b"}}}], "length": {"value": 0.0426193, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "40b10f22-d50a-4135-8e84-81fa97145e9b", "name": "l(r:p1rdm14000-p1rlv13726)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea740eb8-42c6-4417-97d6-7c73f1fc2bc8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "642597e6-fe60-442f-b356-2be6f21677b2"}}}], "length": {"value": 0.00697416, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "072d74a7-35ce-499b-be52-d6ad80a0dc15", "name": "l(r:p1rdm13999-p1rdm14000)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f85240e6-bbbe-4b90-8419-a00a3ca9613f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea740eb8-42c6-4417-97d6-7c73f1fc2bc8"}}}], "length": {"value": 0.0139057, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5f658b70-1fd2-4e3d-ac5c-c7a295a50529", "name": "l(r:p1rdm13999-p1rdt6499lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb05d831-1556-4f56-8065-d9d16657caa3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f85240e6-bbbe-4b90-8419-a00a3ca9613f"}}}], "length": {"value": 0.0125149, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f76f9ba9-1ad5-411f-8fe0-e19d0b125427", "name": "l(r:p1rdt6500lv-p1rlv13613)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a20a4242-8a76-49f3-9bf5-3d7aaf751cdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "216537dd-ea7b-461c-b821-99491c41b7f0"}}}], "length": {"value": 0.0114283, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "ebf5f920-605f-4b2b-9361-25feec533c82", "name": "l(r:p1rdm14004-p1rlv13618)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83aa4266-e486-4e00-a09b-7bcdc613a9b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f823a90c-effd-489c-9e0a-c110ccb7b9e8"}}}], "length": {"value": 0.0123108, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "c92a290b-f056-49ba-b87b-2d53df6805ed", "name": "l(r:p1rdm14007-p1rlv13653)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff282b99-30bb-4c1d-acb9-02fafe241577"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c61a243-7736-46a0-a950-7cc811381158"}}}], "length": {"value": 0.0534886, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "a96b6494-0b33-4e6a-86cf-59557654a321", "name": "l(r:p1rdm14002-p1rlv13599)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c0ae3b1-ac0d-43c9-9a1e-c73bd10e3ad8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2a60818-4310-4100-9aa8-35ef37aa5f40"}}}], "length": {"value": 0.0432926, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "6d4b04c7-dd70-46da-9bc3-430fe1b50bb9", "name": "l(r:p1rdm14005-p1rlv13648)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d576dffc-af75-488e-8c51-19aa726f0505"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62a29ac5-7227-43b2-b602-b1189cc93839"}}}], "length": {"value": 0.0533671, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "6fe861c6-ef06-4253-98a7-6b8afb1cd014", "name": "l(r:p1rdm14002-p1rdm14005)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c0ae3b1-ac0d-43c9-9a1e-c73bd10e3ad8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d576dffc-af75-488e-8c51-19aa726f0505"}}}], "length": {"value": 0.00732814, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "b3bdf82d-ea8f-474c-92c9-d4b35eb23516", "name": "l(r:p1rdm14002-p1rdm14007)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff282b99-30bb-4c1d-acb9-02fafe241577"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c0ae3b1-ac0d-43c9-9a1e-c73bd10e3ad8"}}}], "length": {"value": 0.007327430000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "f5e00887-072c-477b-a27b-8a1bb5b644a1", "name": "l(r:p1rdm14004-p1rdm14007)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83aa4266-e486-4e00-a09b-7bcdc613a9b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff282b99-30bb-4c1d-acb9-02fafe241577"}}}], "length": {"value": 0.007320720000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "3c9c08f9-58e9-4367-aee8-72788caa6a7c"}}}}, {"uuid": "8653ff7a-8098-4538-800a-42481de0aacb", "name": "l(r:p1rdm14004-p1rdt6500lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a20a4242-8a76-49f3-9bf5-3d7aaf751cdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83aa4266-e486-4e00-a09b-7bcdc613a9b5"}}}], "length": {"value": 0.00898801, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "f731ee6a-9af9-40b1-a1a2-dadc871f741c", "name": "l(r:p1rdm14008-p1rlv13687)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e5abf33-75a2-446f-9c6c-1f3384b78c24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4671f981-e26e-4f26-9698-7f9068ce6dec"}}}], "length": {"value": 0.00688001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "c55b8ce0-a116-435e-81c7-4803d454bdde", "name": "l(r:p1rdm14009-p1rlv13719)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "592b8095-ba99-4993-a445-9af51fa89f57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44aa3f37-e0db-4050-b47f-ac14b7fa6534"}}}], "length": {"value": 0.00707054, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "1bfc33e4-b04b-4983-8901-3644068a4e2f", "name": "l(r:p1rdm14006-p1rlv13652)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33445b16-68bf-4606-8ac5-def4763fb95d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3310c14a-d1ee-4d0c-8428-d002703c61d5"}}}], "length": {"value": 0.00737761, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "55929b77-1dd1-4d96-8f47-b2896190c205", "name": "l(r:p1rdm14006-p1rdm14009)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "592b8095-ba99-4993-a445-9af51fa89f57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33445b16-68bf-4606-8ac5-def4763fb95d"}}}], "length": {"value": 0.00898801, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "195330b0-ed90-4511-a59e-4f29b3f0af24", "name": "l(r:p1rdm14008-p1rdm14009)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e5abf33-75a2-446f-9c6c-1f3384b78c24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "592b8095-ba99-4993-a445-9af51fa89f57"}}}], "length": {"value": 0.00898801, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "876bd333-5a47-4e8f-a9b1-cc4abcb2151a", "name": "l(r:p1rdm14008-p1rdt6500lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a20a4242-8a76-49f3-9bf5-3d7aaf751cdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e5abf33-75a2-446f-9c6c-1f3384b78c24"}}}], "length": {"value": 0.017982000000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "3c9c08f9-58e9-4367-aee8-72788caa6a7c"}}}}, {"uuid": "342ef8ad-e444-494e-ad4c-92901121506a", "name": "l(r:p1rdt6501lv-p1rlv13600)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59ab6d81-a91c-4350-8f94-abe02e3e1555"}}}], "length": {"value": 0.0222413, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "390e5cf1-b1e6-49ab-b980-6194c2f0c071", "name": "l(r:p1rdt6501lv-p1rlv13606)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29838633-5c95-4b73-8227-cfa7f4aedc32"}}}], "length": {"value": 0.0135771, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e9b80295-684b-4497-aeca-3ac73bfe04d1", "name": "l(r:p1rdt6501lv-p1rlv13608)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5e8caf4-4d81-4bbd-98df-6622c5ad0563"}}}], "length": {"value": 0.00679883, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5b4b52a4-31e7-4087-bb1e-24c7c491bf3e", "name": "l(r:p1rdt6501lv-p1rlv13619)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f693a1d2-5499-4810-9458-f205eda265fa"}}}], "length": {"value": 0.0334092, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "97e8fcf2-7304-40bf-ae9b-e7cdd37a4fb7"}}}}, {"uuid": "d453bf68-5c20-462a-8a81-469dded3c831", "name": "l(r:p1rdt6501lv-p1rlv13622)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4540b2cb-ee21-4515-a7ca-fbca371f060d"}}}], "length": {"value": 0.0312591, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c582d791-9861-4686-a34a-1a5ee46f781c", "name": "l(r:p1rdt6501lv-p1rlv13637)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30c470ac-39d1-4379-9ae7-790d912bce2c"}}}], "length": {"value": 0.0185945, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "99295cd8-2b7e-4cca-aa16-0b8d909f4c06", "name": "l(r:p1rdm14016-p1rlv13683)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b7d4c6f-98b5-4cec-b8a4-9311b5fc92bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "de45dc59-3e0a-4b33-8cf4-d5213b0140c1"}}}], "length": {"value": 0.0352211, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ca89eb81-8901-400a-9265-f885565a3423", "name": "l(r:p1rdm14016-p1rdt6501lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b7d4c6f-98b5-4cec-b8a4-9311b5fc92bd"}}}], "length": {"value": 0.0288269, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2db45833-0f3f-4f0f-837b-c37add7fd184", "name": "l(r:p1rdt6502lv-p1rlv13601)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7682e9f7-1272-4781-b128-34c7329afe49"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91953a27-bbc7-494a-bec2-a12b4c0f6af6"}}}], "length": {"value": 0.015644, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7c0d2bec-f934-477c-9124-d3536213c299", "name": "l(r:p1rdt6502lv-p1rlv13634)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7682e9f7-1272-4781-b128-34c7329afe49"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "987b05d5-9bb9-434d-98b3-623ee5014870"}}}], "length": {"value": 0.015644, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c18dbc35-bff3-4eed-8032-7a9d865d9cb8", "name": "l(r:p1rdt6505lv-p1rlv13604)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387e7785-8d40-4ddd-8c2b-14a83d4e7401"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9b83bdf-b564-4997-bfc7-1be2f2e58199"}}}], "length": {"value": 0.0220113, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "316eb2e4-da26-4004-9bc7-4f0f810b0c35", "name": "l(r:p1rdt6505lv-p1rlv13605)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387e7785-8d40-4ddd-8c2b-14a83d4e7401"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c39dc6f1-08b5-4bc1-a6ae-be0076af56aa"}}}], "length": {"value": 0.021993400000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c4d7cf80-30b7-49d5-bc93-a33daa9a50b4", "name": "l(r:p1rdt6505lv-p1rlv13654)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387e7785-8d40-4ddd-8c2b-14a83d4e7401"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7be734c-88e2-42c1-8061-f4632bd05759"}}}], "length": {"value": 0.0264068, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2fa21c7c-b71e-481c-8ba0-705b20e1dd84", "name": "l(r:p1rdt6505lv-p1rlv13676)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387e7785-8d40-4ddd-8c2b-14a83d4e7401"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8df1a69e-5b18-4eef-ab60-543a97257297"}}}], "length": {"value": 0.028008200000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4c9980ea-c901-4e92-bb89-6f907b3a5dca", "name": "l(r:p1rdt6505lv-p1rlv13715)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387e7785-8d40-4ddd-8c2b-14a83d4e7401"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a822fdb0-b531-49b0-89da-b517e5ae6e3a"}}}], "length": {"value": 0.00829409, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6c069c68-5c44-4ed0-b1cf-af99663412ef", "name": "l(r:p1rdt6507lv-p1rlv13610)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5844baa-5e0f-4edd-9122-fe4255adad0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17d92377-b4f1-4194-89cd-130bddb9b77c"}}}], "length": {"value": 0.0581195, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "89882ab7-3fbe-4a43-8813-4000db50953d", "name": "l(r:p1rdm14031-p1rlv13712)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a2f5fad-c0a9-4f62-a318-ef00c0d4f470"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ab8bce-7c02-4c7b-962e-3fb44a3ab7a9"}}}], "length": {"value": 0.0677651, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8f8439ca-eff8-40f9-aa8d-d359f0721d26", "name": "l(r:p1rdm14031-p1rdt6507lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5844baa-5e0f-4edd-9122-fe4255adad0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a2f5fad-c0a9-4f62-a318-ef00c0d4f470"}}}], "length": {"value": 0.0164067, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "efd01f17-490e-47c7-8d2e-568a421cec6a", "name": "l(r:p1rdt6508lv-p1rlv13611)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "630b2a63-622f-4f78-8390-77c69ba7e393"}}}], "length": {"value": 0.00515213, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5a1a2657-849d-4e13-8c0c-965a8a7ab30e", "name": "l(r:p1rdt6508lv-p1rlv13666)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5868c24b-2a58-459b-8650-a6072241aca8"}}}], "length": {"value": 0.006682040000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c45a4782-6379-4df5-896d-ba72b47ee680", "name": "l(r:p1rdt6508lv-p1rlv13685)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f777bc74-e6f3-4e80-bb72-0764964db21e"}}}], "length": {"value": 0.04116050000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "485ec2d2-baf3-4031-b775-f3a35c51e1f2", "name": "l(r:p1rdt6508lv-p1rlv13701)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa7a324e-d367-49a5-820a-b18e72243265"}}}], "length": {"value": 0.00980837, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "63ca6e20-b870-4ea1-aaea-7904c242ba8a", "name": "l(r:p1rdt6508lv-p1rlv13707)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "286623b3-af08-4a60-896a-1f5b85fe04a5"}}}], "length": {"value": 0.0432014, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4a2c57de-4589-43cc-8447-5abb34d130a0", "name": "l(r:p1rdm14033-p1rlv13651)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "572123ef-d255-42a9-9c61-95d99aaff775"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c808261e-a49e-4954-bdc4-a8b63d0ee25b"}}}], "length": {"value": 0.0148948, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d9124535-9f55-4e17-90ec-cf5341d9c500", "name": "l(r:p1rdm14033-p1rlv13728)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "572123ef-d255-42a9-9c61-95d99aaff775"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9657a993-0005-4ffc-8c9f-18e80a491070"}}}], "length": {"value": 0.00972322, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cc27c9f6-9b6e-4814-b9c7-7166cc2d1bed", "name": "l(r:p1rdm14033-p1rdt6508lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "572123ef-d255-42a9-9c61-95d99aaff775"}}}], "length": {"value": 0.0189224, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3162f10d-4158-469a-96cd-a51fa01fb20a", "name": "l(r:p1rdt6509lv-p1rlv13612)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f817a28f-c650-4eb4-84c0-751fe5053c75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6eda3e97-a618-41ab-ae55-ba67f6bb0234"}}}], "length": {"value": 0.00552959, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9d01a910-b603-4852-9d53-708297ee103a", "name": "l(r:p1rdt6509lv-p1rlv13628)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f817a28f-c650-4eb4-84c0-751fe5053c75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e47df44a-79f1-423b-a295-c9c354795895"}}}], "length": {"value": 0.0122449, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "516a46a4-a886-40b9-b1ea-e684b208f509", "name": "l(r:p1rdm14041-p1rlv13627)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b65a5fd-f38e-447a-a51a-e7a214ba6bcc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bd69c55-2141-4c8e-becf-efa4bff8a63e"}}}], "length": {"value": 0.0158712, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8cb36820-73d5-492e-8845-b9ec92e8fa18", "name": "l(r:p1rdm14041-p1rlv13659)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b65a5fd-f38e-447a-a51a-e7a214ba6bcc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "122e0772-7de6-4117-b1d3-caafbbbc8e22"}}}], "length": {"value": 0.009054330000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d8df7836-4789-448b-894e-7c1c617c95d9", "name": "l(r:p1rdm14041-p1rlv13660)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b65a5fd-f38e-447a-a51a-e7a214ba6bcc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3d6fd13-2f04-4f23-97a3-cdf99159174c"}}}], "length": {"value": 0.0113115, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "068f969c-0c98-4e0f-9524-1a21a3b8987d", "name": "l(r:p1rdm14041-p1rlv13677)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b65a5fd-f38e-447a-a51a-e7a214ba6bcc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9aa7e62-8974-4ef0-aa5a-bcd545245aea"}}}], "length": {"value": 0.0329272, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "65146649-1d08-42cb-af6c-acc8a012a05e", "name": "l(r:p1rdm14040-p1rlv13624)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1252c522-5ced-4f4c-908c-f58501ad6f92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a5746d1-24a6-4ae4-b5dc-cef23b56660d"}}}], "length": {"value": 0.00954632, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3ae44c1c-f5ef-4516-a648-5583d34cf7a6", "name": "l(r:p1rdm14040-p1rlv13721)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1252c522-5ced-4f4c-908c-f58501ad6f92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6097c903-70fc-4635-a66c-fee2243ba545"}}}], "length": {"value": 0.012462500000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "20173122-d8a7-4c92-a3b7-8ddb76680383", "name": "l(r:p1rdm14040-p1rdm14041)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b65a5fd-f38e-447a-a51a-e7a214ba6bcc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1252c522-5ced-4f4c-908c-f58501ad6f92"}}}], "length": {"value": 0.0125149, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "80fdbbc2-08c7-494f-bc26-6b81701d774b", "name": "l(r:p1rdm14041-p1rdt6509lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f817a28f-c650-4eb4-84c0-751fe5053c75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b65a5fd-f38e-447a-a51a-e7a214ba6bcc"}}}], "length": {"value": 0.0139057, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "52d0c8fb-a66f-4033-93f4-79e9ae946d79"}}}}, {"uuid": "c8f1e6a0-c36c-4ce6-99e7-ee182b295e7f", "name": "l(r:p1rdm14043-p1rlv13633)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9be8942c-8459-4c1d-a3b0-a89ee5cced4e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b3fe33f-fdcf-42f5-be08-8da15a4d4958"}}}], "length": {"value": 0.036068300000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "95e07a95-448b-4b98-80fa-457bcde4ecc4", "name": "l(r:p1rdm14043-p1rlv13663)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9be8942c-8459-4c1d-a3b0-a89ee5cced4e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54887ca7-ae23-42d0-a715-aed8baa38ade"}}}], "length": {"value": 0.0442205, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "17a54982-d8e3-4917-97dd-8e7dbe136d17", "name": "l(r:p1rdm14043-p1rlv13672)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9be8942c-8459-4c1d-a3b0-a89ee5cced4e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32bec8ad-b312-4502-a2a1-6a4c9b2dd87a"}}}], "length": {"value": 0.00371517, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "3e5beb3a-4808-431b-a276-401a1bc26c44", "name": "l(r:p1rdm14043-p1rlv13686)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9be8942c-8459-4c1d-a3b0-a89ee5cced4e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60fe0a16-aa4d-4fe8-9f39-81bfa13b505f"}}}], "length": {"value": 0.0111527, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9accb5a7-67c9-4b12-89a4-03446ebd99ee", "name": "l(r:p1rdm14043-p1rdt6509lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f817a28f-c650-4eb4-84c0-751fe5053c75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9be8942c-8459-4c1d-a3b0-a89ee5cced4e"}}}], "length": {"value": 0.0139057, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ca70462c-125c-4416-a604-f000d21623d6", "name": "l(r:p1rdt6510lv-p1rlv13614)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d62fe3b-7644-46d1-8a15-e86d95ae8b2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3de8b994-01ba-4eae-b9cf-7fb174d32355"}}}], "length": {"value": 0.01924, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bb7235ed-bd23-4bb0-99ce-00d534f6ceba", "name": "l(r:p1rdt6510lv-p1rlv13680)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d62fe3b-7644-46d1-8a15-e86d95ae8b2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85b910cd-def8-41d8-ad47-3c074a54ad8d"}}}], "length": {"value": 0.012694, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "52d0c8fb-a66f-4033-93f4-79e9ae946d79"}}}}, {"uuid": "84cbab40-20ee-4d00-86b9-42817ede7a15", "name": "l(r:p1rdt6510lv-p1rlv20467)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d62fe3b-7644-46d1-8a15-e86d95ae8b2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58e2b774-ac04-435e-9e03-573b3aa94cfb"}}}], "length": {"value": 0.00748899, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ff0d00c0-ac17-4823-ada8-ba030479f1ce", "name": "l(r:p1rdt6512lv-p1rlv13616)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "850d5b69-14cf-4a18-8cb0-4f1b3033b0aa"}}}], "length": {"value": 0.0125419, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2ab15224-388d-4616-8bd6-5a213b6945ec", "name": "l(r:p1rdt6512lv-p1rlv13643)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20009de0-cbe7-4b4f-a046-425a6ae71925"}}}], "length": {"value": 0.0106471, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9af93afe-5223-45fd-a014-1b40d134690d", "name": "l(r:p1rdt6512lv-p1rlv13646)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fe0466e-cce5-4c6c-b13f-cedd349b6944"}}}], "length": {"value": 0.00566202, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "023df541-8d16-46bf-b4d4-675baa72fc8a", "name": "l(r:p1rdt6512lv-p1rlv13650)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fa2041e-34c4-4f1f-a329-74969c3da75f"}}}], "length": {"value": 0.0342408, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "13f8ad6d-758e-44f8-8220-06aef0a4c41b", "name": "l(r:p1rdt6512lv-p1rlv13725)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e290046b-c936-4f51-b4ef-632bf572ab7f"}}}], "length": {"value": 0.0322281, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4947106f-8e2e-4805-b3b7-5e9672aadeac", "name": "l(r:p1rdm14062-p1rlv13664)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3ed4387-9ecb-43c4-a392-e72bc5cb32b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70cf02cc-8f1b-48ab-b9e6-50c3e58ad9ae"}}}], "length": {"value": 0.0332206, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "fe342819-1380-4393-a27d-ccc1439cd615", "name": "l(r:p1rdm14062-p1rlv13681)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3ed4387-9ecb-43c4-a392-e72bc5cb32b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60f08cde-51d3-4b51-9ab5-b61c8043950f"}}}], "length": {"value": 0.00918014, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "96b443e2-11df-4e89-981c-41c80cf02023", "name": "l(r:p1rdm14062-p1rlv13717)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3ed4387-9ecb-43c4-a392-e72bc5cb32b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdbfe616-f51f-416a-94ce-6e676d300226"}}}], "length": {"value": 0.00916206, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "488c4454-9ad4-484f-8d9c-aca4b7f2fd67", "name": "l(r:p1rdm14062-p1rlv20509)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3ed4387-9ecb-43c4-a392-e72bc5cb32b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fe37b51-0258-4812-9d96-3cc28c4bd55b"}}}], "length": {"value": 0.00548688, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "022d323e-07da-4138-8e8b-44b035820841", "name": "l(r:p1rdm14062-p1rdt6512lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3ed4387-9ecb-43c4-a392-e72bc5cb32b6"}}}], "length": {"value": 0.018909400000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e3150130-99fc-424b-93c8-da14b313e743", "name": "l(r:p1rdm14063-p1rlv13671)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "485928ba-ff70-4be2-89ff-721ff82269fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2f95b8b-190c-4df2-9dd2-daee5efde34b"}}}], "length": {"value": 0.0398564, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b6d97809-156e-4113-af17-e0200a96fbff", "name": "l(r:p1rdm14063-p1rlv13714)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "485928ba-ff70-4be2-89ff-721ff82269fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17936036-1191-4f91-bc12-2298db7b77e3"}}}], "length": {"value": 0.0397956, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e0a8749f-fc99-4c40-843a-c950cd6b3617", "name": "l(r:p1rdm14063-p1rdt6512lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "485928ba-ff70-4be2-89ff-721ff82269fb"}}}], "length": {"value": 0.0189224, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "033e3f67-3877-4ae0-b6ec-ed4ac02d0081", "name": "l(r:p1rdt6514lv-p1rlv13623)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad6bef77-8f39-43b4-b2d7-58aa6e45a60b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80f60ab3-722f-4765-8b91-4fd0196171d7"}}}], "length": {"value": 0.0879332, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4c3fb8e9-1d83-4791-8274-8e68fb1645a7", "name": "l(r:p1rdt6514lv-p1rlv13716)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad6bef77-8f39-43b4-b2d7-58aa6e45a60b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb3b4207-12ad-46e6-b4de-59149a46f8a1"}}}], "length": {"value": 0.107138, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b4624fcd-3303-45b7-aeab-e8182705ea7d", "name": "l(r:p1rdm14072-p1rlv13640)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "395dac73-8fae-4718-a28c-191a76a298f2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "653bdc0d-5b21-4640-861b-b88ddb5c651a"}}}], "length": {"value": 0.0819367, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c040ef88-e64c-4303-83fd-b18d037139ca", "name": "l(r:p1rdm14072-p1rdt6514lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad6bef77-8f39-43b4-b2d7-58aa6e45a60b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "395dac73-8fae-4718-a28c-191a76a298f2"}}}], "length": {"value": 0.0139057, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "caa8dcf0-ff72-42e0-b35b-3d850862220e", "name": "l(r:p1rdt6515lv-p1rlv13625)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b92f8bcd-91ce-42bd-be69-0b43cb9d4122"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c667408-52a0-4258-8e93-557c94520a1e"}}}], "length": {"value": 0.09092920000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "61b204a7-5100-4427-bab6-d2a4ff8ae7df", "name": "l(r:p1rdt6515lv-p1rlv19156)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b92f8bcd-91ce-42bd-be69-0b43cb9d4122"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7538ab85-10b4-4f60-98f8-179e954173b0"}}}], "length": {"value": 0.091396, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "c8be5034-7901-4e58-97e7-41c162aba1d0", "name": "l(r:p1rdt6515lv-p1rlv19163)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b92f8bcd-91ce-42bd-be69-0b43cb9d4122"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fed6fcd4-3c97-4f62-a1a7-0b66394218e1"}}}], "length": {"value": 0.0956659, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "6e8f9e3f-5286-4b5c-b948-13135572f5cc", "name": "l(r:p1rdt6515lv-p1rlv19165)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b92f8bcd-91ce-42bd-be69-0b43cb9d4122"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ebd10471-ab4c-4cb7-a822-a83ef20e9854"}}}], "length": {"value": 0.104528, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "188e1e24-abff-4778-add9-5cd6da283c9a", "name": "l(r:p1rdm14075-p1rlv13645)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2659bd3-f6ca-4d74-87c8-f92596986cb5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1acad56e-b6d6-4fa7-a925-f242c1558eef"}}}], "length": {"value": 0.0654705, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "3f25d6c2-6bb8-45d7-aefd-259a75c39fa3", "name": "l(r:p1rdm14075-p1rdt6515lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b92f8bcd-91ce-42bd-be69-0b43cb9d4122"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2659bd3-f6ca-4d74-87c8-f92596986cb5"}}}], "length": {"value": 0.00777706, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "7d73691e-3ace-4804-a2fc-b1e7bb2fc029", "name": "l(r:p1rdt6516lv-p1rlv13629)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "119a8559-8e6c-4314-9bbd-37ef3adde415"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b4358536-b06f-486d-b336-3a8576b428d0"}}}], "length": {"value": 0.0117712, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a9dc2406-fd4a-460a-b563-9f3869e7a46e", "name": "l(r:p1rdt6516lv-p1rlv13638)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "119a8559-8e6c-4314-9bbd-37ef3adde415"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db3908f7-94f5-43a7-a3de-1f6c9b72ebd4"}}}], "length": {"value": 0.009298230000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c42d401a-12f5-41aa-8978-0bab6fef0238", "name": "l(r:p1rdt6516lv-p1rlv13692)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "119a8559-8e6c-4314-9bbd-37ef3adde415"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "091b545a-eb31-4bea-a0a6-5aa9c7a8397f"}}}], "length": {"value": 0.022541900000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9ce6b824-e446-47d8-9b7f-8e6925a36c68", "name": "l(r:p1rdt6516lv-p1rlv13708)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "119a8559-8e6c-4314-9bbd-37ef3adde415"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a230534-6927-4af8-ba54-6ab4c9c32d21"}}}], "length": {"value": 0.020454, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "082fc58b-a217-4336-9a0d-065c229b7951", "name": "l(r:p1rdt6517lv-p1rlv13630)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5783bae9-2c74-473f-bf18-db40bc975409"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f474e4ba-6300-4014-afe9-c245e08cf3c5"}}}], "length": {"value": 0.0228311, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3c1f055c-199b-4923-bf89-d99e150d0252", "name": "l(r:p1rdm14084-p1rlv13641)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "822f96e6-61c5-455d-8a53-a494b49c9237"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eb10938-4b73-406c-bed4-0bd01e0bc20d"}}}], "length": {"value": 0.0127698, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "dfb21f10-33c3-41a3-a751-c1d7711c1c4f", "name": "l(r:p1rdm14084-p1rdt6517lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5783bae9-2c74-473f-bf18-db40bc975409"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "822f96e6-61c5-455d-8a53-a494b49c9237"}}}], "length": {"value": 0.0159549, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b10d847c-d604-4ede-9f26-ef7617eb21ce", "name": "l(r:p1rdt6518lv-p1rlv13647)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b16b03-1922-4aeb-8e70-d0e1387fbcab"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8753d37-07f1-45c6-a483-43cbfb6bf107"}}}], "length": {"value": 0.025624100000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "16c1caa6-a0ac-4132-a871-c1d589aa9772", "name": "l(r:p1rdm14085-p1rlv13632)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c597db56-a6af-472d-a7a2-e331175a2aae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b712121-d0c2-488a-9224-bea72928796f"}}}], "length": {"value": 0.028921, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "37be34c8-1e2b-49f9-8cb3-aa295a059daa", "name": "l(r:p1rdm14085-p1rdt6518lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b16b03-1922-4aeb-8e70-d0e1387fbcab"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c597db56-a6af-472d-a7a2-e331175a2aae"}}}], "length": {"value": 0.0331741, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "344cfb2a-35cd-4e8b-869a-9b28c99943fd", "name": "l(r:p1rdm14087-p1rlv20154)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180c5680-acd1-4988-ac36-1f351c3f9418"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02f2e50e-d42d-47d1-9274-d840042b64d1"}}}], "length": {"value": 0.0527706, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7ae66157-15aa-48f6-87af-00e3416e452b", "name": "l(r:p1rdm14087-p1rlv20161)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180c5680-acd1-4988-ac36-1f351c3f9418"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11a125b8-023c-4748-98a9-d74e9e0a7d23"}}}], "length": {"value": 0.04340720000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2f1e15b7-c811-40be-81ac-e05c3e936d83", "name": "l(r:p1rdm14087-p1rdt6518lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b16b03-1922-4aeb-8e70-d0e1387fbcab"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180c5680-acd1-4988-ac36-1f351c3f9418"}}}], "length": {"value": 0.0198942, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "228f74d1-87c0-4843-809b-e393c84a2239", "name": "l(r:p1rdt6519lv-p1rlv13636)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "606673ea-bcd2-459a-a0af-efb8b31c600c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4d3fe62-b327-4fc6-b2aa-795c9475019a"}}}], "length": {"value": 0.052177, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "167607d2-178f-4e8d-82c4-9bfd9975fab7", "name": "l(r:p1rdm14090-p1rlv13678)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e06b069-62f8-40c8-9abc-d4cc83937e41"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32b75c61-4e97-4e21-a786-8aab7a2d88f8"}}}], "length": {"value": 0.0759194, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "11760911-163e-44ae-af9b-fbbdf0f687b8", "name": "l(r:p1rdm14090-p1rdt6519lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "606673ea-bcd2-459a-a0af-efb8b31c600c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e06b069-62f8-40c8-9abc-d4cc83937e41"}}}], "length": {"value": 0.00898801, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "259929c5-0a19-4150-9cea-ff8dc5a0a7bd", "name": "l(r:p1rdt6520lv-p1rlv13639)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13c02cd3-cff3-4988-95b9-3993b9541427"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5484eab0-53a8-471c-92ec-29c11c08e740"}}}], "length": {"value": 0.0157099, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b03c2024-3c7a-4d2e-8e6e-7d42de59c0a2", "name": "l(r:p1rdt6520lv-p1rlv13669)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13c02cd3-cff3-4988-95b9-3993b9541427"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "607d3b54-2cea-476b-afe2-ea40c6c02ddc"}}}], "length": {"value": 0.00818072, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a2c154da-c79e-4d92-abad-f78947b543a8", "name": "l(r:p1rdm14092-p1rlv13662)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db3abe20-2ffb-4bf8-b425-5613701bd3f2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e55b944-ffad-47bf-8348-799afa4c7a1d"}}}], "length": {"value": 0.0117517, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2509fb4d-0dfc-4537-aac7-0cd0a6a4c808", "name": "l(r:p1rdm14096-p1rlv13679)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0c27b40-83a9-4938-bc12-a2ae57d5eafb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "284bbc5d-bb49-404d-823e-08ec543c90b8"}}}], "length": {"value": 0.0111879, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ad959039-7919-4664-bbfa-b8fc3bb04d8b", "name": "l(r:p1rdm14097-p1rlv13705)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb3a7829-4233-4af9-9679-08bd114bc00e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f409299-5ac0-4f31-a217-d0aef7fbc4d2"}}}], "length": {"value": 0.006644980000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f0c5ad2b-ab0c-47ff-996f-359b98a541c0", "name": "l(r:p1rdm14096-p1rdm14097)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0c27b40-83a9-4938-bc12-a2ae57d5eafb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb3a7829-4233-4af9-9679-08bd114bc00e"}}}], "length": {"value": 0.0158664, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "612c5150-f8fd-4503-afd5-72b168f3a3c8", "name": "l(r:p1rdm14092-p1rdm14096)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db3abe20-2ffb-4bf8-b425-5613701bd3f2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0c27b40-83a9-4938-bc12-a2ae57d5eafb"}}}], "length": {"value": 0.011940100000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "48f450bb-ff89-4556-9044-213f13d84df0", "name": "l(r:p1rdm14092-p1rdt6520lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13c02cd3-cff3-4988-95b9-3993b9541427"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db3abe20-2ffb-4bf8-b425-5613701bd3f2"}}}], "length": {"value": 0.0119317, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "2d347746-0969-4a8a-b986-c40ef4f4c015"}}}}, {"uuid": "83174978-498d-4a0c-9123-99b6f97be3f9", "name": "l(r:p1rdm14094-p1rlv13673)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a990c6c-4227-4896-8ea6-e92ce5360087"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9467d2d3-ad80-4bc7-aa9f-cd6e76494552"}}}], "length": {"value": 0.0209007, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d8400413-4b6f-448c-8b9f-35fd9343fb78", "name": "l(r:p1rdm14094-p1rlv13675)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a990c6c-4227-4896-8ea6-e92ce5360087"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c532e298-bdd5-416e-8ebe-a082489ffee6"}}}], "length": {"value": 0.023550600000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "47cee057-d034-469d-844a-fc4156ee7c4e", "name": "l(r:p1rdm14094-p1rdt6520lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13c02cd3-cff3-4988-95b9-3993b9541427"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a990c6c-4227-4896-8ea6-e92ce5360087"}}}], "length": {"value": 0.0125632, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fa38627e-ef06-43f8-96ec-98da2f37c21e", "name": "l(r:p1rdt6521lv-p1rlv13670)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0e4e42c-8dcd-47be-bfe8-b8b1eb4a5f24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce53d307-fc73-487a-8f6a-3a0e0787bf79"}}}], "length": {"value": 0.106379, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e0336142-b978-433d-8847-480a4107f3f4", "name": "l(r:p1rdt6521lv-p1rlv13694)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0e4e42c-8dcd-47be-bfe8-b8b1eb4a5f24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1de2ebf2-3207-4bf7-9702-4c729d99a6cf"}}}], "length": {"value": 0.07348910000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d686aa67-4e56-444b-b892-d06c1d8df229", "name": "l(r:p1rdt6521lv-p1rlv13695)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0e4e42c-8dcd-47be-bfe8-b8b1eb4a5f24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d73963d7-acf4-48b3-8e54-6ee9f403d36f"}}}], "length": {"value": 0.0966562, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ac3a550d-5246-49d8-ab21-eaaf8dd0a54a", "name": "l(r:p1rdm14098-p1rlv13642)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c12be3d4-719e-4567-91d9-c0ff24b783f1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "479d1486-ed05-44fa-8fab-64035623f267"}}}], "length": {"value": 0.0796353, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a1ad23ef-8d9b-43dd-9d37-af210c9edc45", "name": "l(r:p1rdm14098-p1rdt6521lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0e4e42c-8dcd-47be-bfe8-b8b1eb4a5f24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c12be3d4-719e-4567-91d9-c0ff24b783f1"}}}], "length": {"value": 0.0189224, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0e50b778-8db4-4046-9cbf-af628dd42567", "name": "l(r:p1rdm14100-p1rlv13682)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1db9a47a-f0ed-4141-b08e-f01a2ffd804f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a3c050c-cc0d-460e-af02-ce3421431474"}}}], "length": {"value": 0.0988767, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "26c24a09-ea79-4de4-86a7-17356670bdac", "name": "l(r:p1rdm14100-p1rdt6521lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0e4e42c-8dcd-47be-bfe8-b8b1eb4a5f24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1db9a47a-f0ed-4141-b08e-f01a2ffd804f"}}}], "length": {"value": 0.0189224, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fff836a7-3b7a-4332-8fa2-4ccc5047b40b", "name": "l(r:p1rdt6523lv-p1rlv13649)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66df2481-ae4f-4f39-aef4-7af09ce1a8fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43867e2f-79ee-4cec-bed3-0cad0727118c"}}}], "length": {"value": 0.053244900000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c912605f-1e8e-4af3-bc5a-fbd35d1f82bc", "name": "l(r:p1rdm14107-p1rlv13656)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2844042b-3f65-4a8b-8bab-56b42971e6ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8c0a04e-6e22-4da5-9907-7ae8097deb10"}}}], "length": {"value": 0.0192208, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "76751362-f6a1-47cf-a480-da419e869b1d", "name": "l(r:p1rdm14107-p1rlv13690)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2844042b-3f65-4a8b-8bab-56b42971e6ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "71c26ca3-0d61-46b8-a95b-710e0b760b62"}}}], "length": {"value": 0.0119597, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "8c4f49b2-3881-4901-9e2a-bdfedd44bb67", "name": "l(r:p1rdm14107-p1rdt6524lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ec2137a-f978-4808-a023-21f13464998b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2844042b-3f65-4a8b-8bab-56b42971e6ad"}}}], "length": {"value": 0.00891043, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "3f4222b7-7671-4abc-b6ee-713366959169", "name": "l(r:p1rdm14109-p1rlv13700)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2256f06d-59e9-4822-987f-7d26f40415c0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ecf9ee9-2a3c-431b-84c8-02c7c7aaacb1"}}}], "length": {"value": 0.0052345, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "b11a686c-caa0-43bc-9fc6-0c2a668d3c33", "name": "l(r:p1rdm14109-p1rdt6524lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ec2137a-f978-4808-a023-21f13464998b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2256f06d-59e9-4822-987f-7d26f40415c0"}}}], "length": {"value": 0.00891207, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "dac869e3-d445-4ffc-84be-6aab918f7e32", "name": "l(r:p1rdt6527lv-p1rlv13661)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8905812-7e3b-4875-87b5-da95999c5bb0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ef8e6ec-86d3-429c-89b4-6c7260701e70"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "2b6940c8-d947-4c87-a551-5c24bf4ffeb9", "name": "l(r:p1rdt6528lv-p1rlv13667)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d097d9be-dd3a-4616-a873-8ab5013c4e72"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d6cdd514-204d-4a86-b0f3-a9bc4990a2aa"}}}], "length": {"value": 0.0382292, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "3c9c08f9-58e9-4367-aee8-72788caa6a7c"}}}}, {"uuid": "c6f600b4-98d6-4e13-a8d6-9dc0d58ae55a", "name": "l(r:p1rdt6528lv-p1rlv13691)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d097d9be-dd3a-4616-a873-8ab5013c4e72"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "850df31b-ee95-4903-93b7-6e5911e8f8a0"}}}], "length": {"value": 0.0619169, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "feff346b-96b0-43c5-ae5a-f9eddc172f07", "name": "l(r:p1rdm14115-p1rlv13689)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b51fe8ae-f6d7-48c7-9f84-22fc7c1c1ba9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e5db11f-0418-4119-9c71-26619456fd7b"}}}], "length": {"value": 0.0409354, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "3c183149-1fd7-4707-9de8-d0a10af6da6f", "name": "l(r:p1rdm14115-p1rdt6528lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d097d9be-dd3a-4616-a873-8ab5013c4e72"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b51fe8ae-f6d7-48c7-9f84-22fc7c1c1ba9"}}}], "length": {"value": 0.00777706, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "67b7cc4c-7757-4d4e-8d9f-66ce36da8415", "name": "l(r:p1rdt6530lv-p1rlv13684)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4ee2d3a-e97c-4ec4-9fa0-d7db1b3e9253"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ec49353-14d1-4917-83bc-ca62cd94bf30"}}}], "length": {"value": 0.0531129, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8e8b88c6-aab7-4e5c-b8b9-c3c64a663429", "name": "l(r:p1rdt6531lv-p1rlv13693)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf4a2da0-682a-4119-b398-feaa6f5a8498"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5815b75-1226-4221-9bcb-bc75ce85fa17"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "ebaa7012-6c65-4b0d-908b-50ddad06d587", "name": "l(r:p1rdm14120-p1rlv13706)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75c95c35-ea3f-4958-9512-606f78de92b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e60fc98a-9c1d-4975-a9b9-e37271b4ac81"}}}], "length": {"value": 0.0324151, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "3c9c08f9-58e9-4367-aee8-72788caa6a7c"}}}}, {"uuid": "6d45312d-0cad-43fb-9bad-2ce0e6ad3c31", "name": "l(r:p1rdm14120-p1rdt6532lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0c3e71a-52a1-49b9-a899-c13d639ac0a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75c95c35-ea3f-4958-9512-606f78de92b5"}}}], "length": {"value": 0.00967577, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "3c9c08f9-58e9-4367-aee8-72788caa6a7c"}}}}, {"uuid": "e6ce21d6-2d77-4b8d-867a-87e52bca3ba4", "name": "l(r:p1rdm14121-p1rlv19151)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7194199d-e430-4b76-ae77-4c7f51477eed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e396aca-4116-40a0-8f17-bcd41f709ea5"}}}], "length": {"value": 0.0466133, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "9efd1997-d5b4-4e77-8930-a5f5597896ee", "name": "l(r:p1rdm14121-p1rdt6532lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0c3e71a-52a1-49b9-a899-c13d639ac0a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7194199d-e430-4b76-ae77-4c7f51477eed"}}}], "length": {"value": 0.00812092, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "c7be9070-30f3-4700-8c06-470b65f8f19f", "name": "l(r:p1rdt6535lv-p1rlv13711)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10f0e9fa-75b8-4eaa-a2ad-b6a3fb4ae859"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2bfaa34-267c-4dfd-8b6d-4ab444ac4048"}}}], "length": {"value": 0.0759779, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "f13c5842-49ff-4779-bdb6-34cd8e664711", "name": "l(r:p1rdt6536lv-p1rlv13713)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b93e7299-60a4-49d6-9d34-885860588861"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee766a99-bb6f-4d5c-8513-9d462103f6fc"}}}], "length": {"value": 0.00770954, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "858b6e8d-19a5-47af-b192-7fb99a49e5e2", "name": "l(r:p1rdt6536lv-p1rlv13723)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b93e7299-60a4-49d6-9d34-885860588861"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0f1846b-2515-48ef-9241-0276932f8e75"}}}], "length": {"value": 0.00908442, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "43e3456d-a787-4d4e-bad6-2710f05d6c28", "name": "l(r:p1rdm14127-p1rlv20478)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57ac4a24-2ddb-46c2-873d-c0b4f3e0600a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cd0effe0-d186-41a8-8197-24144fbc6218"}}}], "length": {"value": 0.0197863, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "4e91a915-48a9-4e23-8849-e14ae8fa716d", "name": "l(r:p1rdm14127-p1rdt6536lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b93e7299-60a4-49d6-9d34-885860588861"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57ac4a24-2ddb-46c2-873d-c0b4f3e0600a"}}}], "length": {"value": 0.00732814, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "9e793d61-64cc-44ff-b17b-fa7b43a1ec8f", "name": "l(r:p1rdt6539lv-p1rlv13727)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b34f50ff-9a1f-439e-81a8-dfcee658926b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36019623-eb62-412c-a591-41494980c9b7"}}}], "length": {"value": 0.0347798, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "68c65b63-27dd-4e30-9d5e-0bb769ae8388", "name": "l(r:p1rdt6539lv-p1rlv20450)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b34f50ff-9a1f-439e-81a8-dfcee658926b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "006c2753-37b3-4b59-82a6-8ce95f316e26"}}}], "length": {"value": 0.01495, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8b013ff2-c5d6-4080-83aa-2395a67efb7c", "name": "l(r:p1rdm14185-p1rlv13784)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36ab64e0-65cb-4515-9c06-4762a398672a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01a18948-75cf-4caf-951f-17a9c8d1f6bc"}}}], "length": {"value": 0.029367, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4c5e3312-2084-435a-bade-59ec2dae5db0", "name": "l(r:p1rdm14185-p1rdt6574lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a43920a-a200-40fe-b5b6-3cdba0c7e784"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36ab64e0-65cb-4515-9c06-4762a398672a"}}}], "length": {"value": 0.0286402, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2ecb58ca-d359-49c0-802f-611cc5587743", "name": "l(r:p1rdm14186-p1rlv13812)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f2b4d47-9668-4bcc-933b-1f422f423e3e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ffd737b-a273-4a6c-91c6-351b5719f658"}}}], "length": {"value": 0.011645100000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c1340aaa-b2e7-423c-a24c-4984fc6527d5", "name": "l(r:p1rdm14186-p1rdt6574lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a43920a-a200-40fe-b5b6-3cdba0c7e784"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f2b4d47-9668-4bcc-933b-1f422f423e3e"}}}], "length": {"value": 0.0169575, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "88709a42-68a3-404c-a28c-0c84626b3f70", "name": "l(r:p1rdt6581lv-p1rlv13797)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "608e485b-13ce-493b-be96-ab83ad733c92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65052833-aec9-4363-a0cf-4d70fa9bb0ce"}}}], "length": {"value": 0.0873919, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7a451c89-27b1-4961-b1d0-940b9033cd52", "name": "l(r:p1rdt6581lv-p1rlv13811)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "608e485b-13ce-493b-be96-ab83ad733c92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aef2ef8-706c-4316-be01-0707ddf0ac7c"}}}], "length": {"value": 0.06100800000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "93cc41fd-d6c5-4fe6-ae2e-4ba53376e452", "name": "l(r:p1rdm14205-p1rlv13792)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8b7c677-d0bf-47d0-8a2a-78417faa49b9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc5fcb56-435a-4a0d-b442-7489a98ad1cd"}}}], "length": {"value": 0.0873214, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ba97f8d3-dd14-4104-a0f9-e265a224b585", "name": "l(r:p1rdm14205-p1rlv13794)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8b7c677-d0bf-47d0-8a2a-78417faa49b9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9725b6c-5bac-456a-bb6a-ce16a5e6b1a5"}}}], "length": {"value": 0.0656609, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ac827c47-9381-4673-914b-eb251a3782c1", "name": "l(r:p1rdm14205-p1rlv13805)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8b7c677-d0bf-47d0-8a2a-78417faa49b9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83d60921-a1f2-4b9c-9709-d2be59b82db5"}}}], "length": {"value": 0.10165500000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "374da000-183c-490f-b8e4-90a747756774", "name": "l(r:p1rdm14205-p1rdt6581lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "608e485b-13ce-493b-be96-ab83ad733c92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8b7c677-d0bf-47d0-8a2a-78417faa49b9"}}}], "length": {"value": 0.0195453, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9b2db3aa-d79e-4506-8730-e7ec07f13f78", "name": "l(r:p1rdm14210-p1rlv19691)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "487eef02-df2d-47fe-a20b-ce1c23064495"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "604cb559-0f18-4ef7-8bcd-a07a7e7f96d7"}}}], "length": {"value": 0.0580592, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9845e9a8-a0e8-4ac8-b23f-43c8a5ec35c0", "name": "l(r:p1rdm14210-p1rdt6581lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "608e485b-13ce-493b-be96-ab83ad733c92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "487eef02-df2d-47fe-a20b-ce1c23064495"}}}], "length": {"value": 0.0390906, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c0b95dfe-dbb0-4b9d-aea3-888bbaae0e4d", "name": "l(r:p1rdt6847lv-p1rlv14434)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7b9897e-b820-424c-adf8-7416de585357"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06135bd7-6a77-4f04-a439-4ce8c245447d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "17c6ca6d-e99b-4b1e-b84a-cfdad5216da5", "name": "l(r:p1rdt6848lv-p1rlv14435)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94c9fa37-fc5c-4243-b0ca-f70840febaee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d07f5065-df41-484d-8e8a-80b2ff4e0e9b"}}}], "length": {"value": 0.012328000000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ed6ec446-d1e2-423b-95f6-3a2124d16714", "name": "l(r:p1rdt6848lv-p1rlv14436)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94c9fa37-fc5c-4243-b0ca-f70840febaee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad66e41a-88ab-443e-b10e-9e7b5b899119"}}}], "length": {"value": 0.012328000000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fab1734a-805a-45b3-bb29-8ec6cc98ff61", "name": "l(r:p1rdt6995lv-p1rlv14828)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09a476ff-48a0-4d27-9cf0-c007e2e98acb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9efa4c9-9832-4aa8-bf44-be0fe1e80cd5"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b55a7233-970e-4b46-bded-059f90e68dc0", "name": "l(r:p1rdt7015lv-p1rlv14908)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "536d7c56-85a6-4167-b4f6-2f39936cd662"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d73b0321-e181-4ecd-b431-9aa6985d56d0"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "72e2c700-4f3a-43a7-acef-5408f66d50aa", "name": "l(r:p1rdt7036lv-p1rlv14952)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a371c8b-1993-432c-b2c6-21b18bec27da"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3c39b0c-9c92-4934-876f-ee5f542f95cc"}}}], "length": {"value": 0.0147598, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d89a8c28-6964-4a2f-886e-cc984f5a7748", "name": "l(r:p1rdm15468-p1rlv15008)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "260ea1f0-7235-47fc-a576-3d647618290e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19231152-1fd1-4e07-a5d9-603c765b2cae"}}}], "length": {"value": 0.028564100000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b8d33ec2-8be0-4cba-8ff9-a32946eebaf4", "name": "l(r:p1rdm15468-p1rdt7036lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a371c8b-1993-432c-b2c6-21b18bec27da"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "260ea1f0-7235-47fc-a576-3d647618290e"}}}], "length": {"value": 0.0178658, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "97dfa04d-243a-4a4e-83a9-a041fdabcedc", "name": "l(r:p1rdt7038lv-p1rlv14954)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "046f6c53-8d9c-43a1-88ce-169ade9e9557"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9e128f5-eb18-44df-8ec4-35bd049ef630"}}}], "length": {"value": 0.00867639, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e3736839-7824-4b4e-aa1d-9cfd6a158fad", "name": "l(r:p1rdt7046lv-p1rlv14974)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cd6a9808-9889-4f16-825d-c9763357c293"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "884ff47e-8e20-4ae8-97bd-287d0ca9dc1b"}}}], "length": {"value": 0.010648, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "47d4754c-c9fb-4def-99b6-c75a6071c19d", "name": "l(r:p1rdt7054lv-p1rlv14992)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf93e681-3ab6-4929-95f1-1da6d5dd28fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4f8b1bc-83c3-4819-9d98-9491df98d494"}}}], "length": {"value": 0.0136862, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "212f4598-9e6d-4b92-a3d1-44610b4910f8", "name": "l(r:p1rdt7054lv-p1rlv15056)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf93e681-3ab6-4929-95f1-1da6d5dd28fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a914ec3a-4883-42a7-b25d-133a1410b8d9"}}}], "length": {"value": 0.0326989, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e190be67-e711-4051-bfd1-1e315ff72cb0", "name": "l(r:p1rdm15533-p1rlv15046)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25a6c92d-ea7f-4ede-af16-713ceedfc7b0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2182c9fd-fd3d-4cb1-b525-192480823e2f"}}}], "length": {"value": 0.0227649, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "37ac8bba-efa1-4bbc-bda6-22e4836756ce", "name": "l(r:p1rdm15533-p1rdt7054lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf93e681-3ab6-4929-95f1-1da6d5dd28fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25a6c92d-ea7f-4ede-af16-713ceedfc7b0"}}}], "length": {"value": 0.0107297, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2a79d577-2b03-4ef6-84e6-afb335adaea1", "name": "l(r:p1rdt7061lv-p1rlv15007)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc33ade7-4471-40b8-8e9b-1846e0ad60e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc29de5b-3a3f-40c0-bde4-9a57f5f62b5c"}}}], "length": {"value": 0.0316282, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "353ebd25-352a-4d04-9ead-4c6d9ddf80fc", "name": "l(r:p1rdm15583-p1rlv15027)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4445ca5-2fed-4352-ab78-66e072a4f482"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07e3b847-cc9a-4f84-bc00-cb4396b6dea0"}}}], "length": {"value": 0.0140589, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2559653c-404f-472f-89ab-b0aa2c33fe36", "name": "l(r:p1rdm15583-p1rdt7067lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ff878e1-3143-4f8e-aa92-74d0a9046417"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4445ca5-2fed-4352-ab78-66e072a4f482"}}}], "length": {"value": 0.06079190000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "257d6011-c8ae-4eed-b4c4-a349d68240c2", "name": "l(r:p1rdm15584-p1rlv15197)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ad4c131-0be7-46e5-8a32-5ff92552dfe6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80a74c6f-c9ec-4742-8fce-ad73c0a6c459"}}}], "length": {"value": 0.0228694, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d7e0b635-9e9d-4d19-b7fe-d028520488c2", "name": "l(r:p1rdm15584-p1rdt7067lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ff878e1-3143-4f8e-aa92-74d0a9046417"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ad4c131-0be7-46e5-8a32-5ff92552dfe6"}}}], "length": {"value": 0.0279022, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b6c37323-999f-4652-8438-a4e92ddec55f", "name": "l(r:p1rdt7069lv-p1rlv15045)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a1566f1-7f0d-41d7-adad-425c9a344eb0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "baccbdab-efc0-487d-b00d-38d3d4be57b4"}}}], "length": {"value": 0.08356350000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f4a62cdd-7ebe-4533-9ebe-30b2bc677c77", "name": "l(r:p1rdt7070lv-p1rlv15064)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "844bdc22-2e32-43ee-8e0b-26f3f4c107b8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "366c9c98-59f1-46d5-b39c-4046703e5e4b"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "a5acdfb1-a2f0-43f1-87c9-737ff5f1e24f", "name": "l(r:p1rdt7075lv-p1rlv15082)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e0577c2-8275-4303-ad11-2c4f56df3f5c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a56b9ad8-c53b-4652-bf94-a7a7dfb8b306"}}}], "length": {"value": 0.00723071, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "72eeb4f8-eec2-4e80-be4c-3ff5014734e2", "name": "l(r:p1rdt7080lv-p1rlv15109)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d86bd7f-7759-4d74-9c74-d58010498f92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "161d4e7b-30f2-447c-a369-1bfa3ba2cd70"}}}], "length": {"value": 0.0109809, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6dce47af-355e-492c-8ada-a69635288723", "name": "l(r:p1rdt7080lv-p1rlv15125)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d86bd7f-7759-4d74-9c74-d58010498f92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb6d8f13-f04e-4b80-a8dc-e16af1dc860e"}}}], "length": {"value": 0.0299076, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8cdd54a6-9f8d-4ee6-87ab-ae1b4d397431", "name": "l(r:p1rdt7087lv-p1rlv15163)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d0c96fe-78c2-4303-ac5c-bbe440f19666"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdee6d84-9253-4fba-b713-3e41d706e999"}}}], "length": {"value": 0.0407888, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "44e14507-623a-45b0-be7a-6186032730df", "name": "l(r:p1rdt7088lv-p1rlv15170)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f1652e8-6cf7-43d4-8474-e61a74873675"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d2f8fcb-c279-49d5-88be-39e6a1d1990b"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "d401fdd0-f323-47cf-9b6e-243c4816d543", "name": "l(r:p1rdt7089lv-p1rlv15171)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73cfcce9-a925-4f29-9cde-6dd6f50735e1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc7cd505-823c-49bb-9e49-3681267dbef0"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "6e104f67-822c-4dfe-821e-3d2270eaf935", "name": "l(r:p1rdt7090lv-p1rlv15180)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d6a4c80-d261-4350-8224-8fe5191459c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e218b01d-f713-4baf-9688-7e77ea413c8c"}}}], "length": {"value": 0.0031637000000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b937d1b0-3310-4bcf-9eec-ea96efd2c7d7", "name": "l(r:p1rdt7201lv-p1rlv15394)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6718b871-3967-4c29-83e5-441799c7fb92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd21ae8b-7841-43b4-871f-316c4b8b4cd2"}}}], "length": {"value": 0.0100846, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5875340a-352d-4b74-98dc-8883439cd675", "name": "l(r:p1rdt7201lv-p1rlv15399)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6718b871-3967-4c29-83e5-441799c7fb92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ec1f313-f341-498c-b1c2-6669b1cbc629"}}}], "length": {"value": 0.042765000000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "af21b504-5bae-4a97-84c8-ae9d4024e5de", "name": "l(r:p1rdt7201lv-p1rlv15419)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6718b871-3967-4c29-83e5-441799c7fb92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8bc46399-0276-4ae7-aa8b-4cdd3d3555e8"}}}], "length": {"value": 0.018884, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7be73f4f-717a-4cc3-883f-c8f78b45e694", "name": "l(r:p1rdt7201lv-p1rlv15478)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6718b871-3967-4c29-83e5-441799c7fb92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "335df4da-50d2-4fbe-a271-ac04257d35c7"}}}], "length": {"value": 0.031123500000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c680c5e9-2427-48d6-b643-b718a5387491", "name": "l(r:p1rdt7201lv-p1rlv15523)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6718b871-3967-4c29-83e5-441799c7fb92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37ccfa64-1373-49b2-85f6-279abea3c945"}}}], "length": {"value": 0.0693229, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ff3b35e7-9cbd-4064-b36f-4258d2d5cc0d", "name": "l(r:p1rdt7220lv-p1rlv15418)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d5e45d6-867a-4442-8258-2c04891dbc4b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9ca373a-b1c3-464d-bbe3-c05b728beb30"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "53336b97-0132-489e-86d2-5eec0f08b652", "name": "l(r:p1rdt7224lv-p1rlv15487)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d6a6156f-e72a-41f0-a307-e6030de24fde"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "921f8f54-ff83-4d2f-8bf4-ee80bab64ce8"}}}], "length": {"value": 0.0279743, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "907ce719-e56e-447c-b64f-d358a020f2fe", "name": "l(r:p1rdm15891-p1rlv15423)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79c5341b-3cd2-41a3-8bbf-e50857b00dae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26009a7e-9bfc-4967-af28-4d8937539eb1"}}}], "length": {"value": 0.027741000000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "393d7862-5b0a-4473-8ea7-c88cb9850068", "name": "l(r:p1rdm15891-p1rlv15474)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79c5341b-3cd2-41a3-8bbf-e50857b00dae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34e0ffc2-da17-441b-bd4d-26d5a1104712"}}}], "length": {"value": 0.0128476, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c8ea9ba6-341b-45bd-b369-354bb85e916f", "name": "l(r:p1rdm15891-p1rdt7224lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d6a6156f-e72a-41f0-a307-e6030de24fde"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79c5341b-3cd2-41a3-8bbf-e50857b00dae"}}}], "length": {"value": 0.0173084, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c4bc4441-c550-4b03-b0a0-efd60aadab66", "name": "l(r:p1rdt7248lv-p1rlv15466)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2087cee5-9f6e-4400-8ca8-bbb120cd4dae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "544be417-0db6-45a7-8314-ec40944781fa"}}}], "length": {"value": 0.00486903, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "15f7249a-14e6-4e3e-b936-42cf2e976a8b", "name": "l(r:p1rdt7248lv-p1rlv15483)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2087cee5-9f6e-4400-8ca8-bbb120cd4dae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c4e3eac-0b1a-4feb-b39f-079c6d2c1d82"}}}], "length": {"value": 0.0134294, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "04240cde-fe5e-4ae9-98d1-50fa051dd3c0", "name": "l(r:p1rdt7248lv-p1rlv15488)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2087cee5-9f6e-4400-8ca8-bbb120cd4dae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6579cc93-2b08-4010-816d-3bef509000cd"}}}], "length": {"value": 0.0434873, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2566c35a-0bf0-403c-be22-cd9edfb06e03", "name": "l(r:p1rdt7248lv-p1rlv15542)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2087cee5-9f6e-4400-8ca8-bbb120cd4dae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b09822b3-a220-48ff-ad4f-62fca602f8b6"}}}], "length": {"value": 0.0301654, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ee4e3654-f1a1-4d89-8f99-33119ceee479", "name": "l(r:p1rdt7253lv-p1rlv15484)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b4f7df4-5453-459d-8599-48fd5f29a9c6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6749066f-4739-41ec-8369-8da49dd9e1c8"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "42542b12-3e8e-4532-8026-92a216e7df40", "name": "l(r:p1rdt7268lv-p1rlv15525)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1130272e-b98e-496f-aeb9-c094cf9cd824"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6eec860d-08cf-4690-93e6-d909429d363d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "34b56bb4-acd5-442f-98dd-ae6a6000c99a", "name": "l(r:p1rdt7298lv-p1rlv15603)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d304e5e0-2cc1-4167-9fad-6fc72228d828"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "688da57a-6f10-4ef8-8763-202a88c3a495"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b91e6094-8b96-4b15-affe-53e4ab5b4c33", "name": "l(r:p1rdt7301lv-p1rlv15606)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43df4c14-a198-4d51-87f4-80000198cd47"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c32ce070-e690-4fc1-92ac-f857691de578"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "03539cf6-cfd1-4610-938a-815b5e0a0d89", "name": "l(r:p1rdt7302lv-p1rlv15607)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e2a141f-436a-45c0-9c15-179301a439c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32291502-d7be-4b45-8af7-cb217448e73f"}}}], "length": {"value": 0.0250222, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5e2c78d8-d1ca-458b-b93a-19d040944540", "name": "l(r:p1rdt7302lv-p1rlv15638)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e2a141f-436a-45c0-9c15-179301a439c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2715a637-d6f0-4e7b-b43e-20836bf4e614"}}}], "length": {"value": 0.0170411, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "114bfef7-5a42-4ad7-9635-b2c6241c80ff", "name": "l(r:p1rdt7306lv-p1rlv15614)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0926064a-1c87-450a-b282-23708de8aec4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ab2d6dc-f5bb-4320-86f3-bf08bb7cf93f"}}}], "length": {"value": 0.0921771, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "78f8538c-a644-4746-acd7-376a89bed97f", "name": "l(r:p1rdt7307lv-p1rlv15617)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ce9dd2c-9e17-46b7-a6f4-e85077664432"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6106bbe7-7a47-4c50-8b2a-d46d7432bccf"}}}], "length": {"value": 0.0103904, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "001dcfc9-4762-41f3-a424-9dcf9b505aca", "name": "l(r:p1rdt7307lv-p1rlv19146)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ce9dd2c-9e17-46b7-a6f4-e85077664432"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0bb184ad-cb26-4317-8c40-f2c8a9f80dab"}}}], "length": {"value": 0.0154412, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "653186ed-25f7-4a39-a24e-19bebabe5ff2", "name": "l(r:p1rdt7307lv-p1rlv19147)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ce9dd2c-9e17-46b7-a6f4-e85077664432"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "546433b3-d70e-49ed-9037-ec88adda79b9"}}}], "length": {"value": 0.0170949, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9cd99dc2-42f9-42a3-a539-3e46d435271c", "name": "l(r:p1rdt7311lv-p1rlv15622)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2d6046b-9ece-4295-a180-41bf2ce47ce6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1151b559-3ae0-4863-9363-9b395bbfc403"}}}], "length": {"value": 0.0755258, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "851d4bfa-61f2-4b83-92e2-03d2d1598df4", "name": "l(r:p1rdt7314lv-p1rlv15629)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97844fdb-b016-4ca3-8777-b0553ead9297"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec0bca53-a58b-4004-8dba-8defca9db4c7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "22a94b20-8087-46c1-8f36-29081323b267", "name": "l(r:p1rdt7318lv-p1rlv15634)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22b1ecce-d5df-4f42-abb2-9f4c3d3a28c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5af6dae-d20f-4a31-9544-b9455cd639bd"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "2c8762b9-a727-48e6-8626-8b0691e21672", "name": "l(r:p1rdt7550lv-p1rlv16114)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58be5cbe-5a7c-4fa5-972d-e03100b3bb46"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5984e209-9f0e-4844-91e6-902c8329f13c"}}}], "length": {"value": 0.010568, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "eb9dc53f-9107-4f64-8499-6dcf08b592a2", "name": "l(r:p1rdt7550lv-p1rlv16178)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58be5cbe-5a7c-4fa5-972d-e03100b3bb46"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "807b0bef-0d34-44a9-a2a9-0c0a11f4ea8e"}}}], "length": {"value": 0.010568, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7c32c8d6-dd37-4fda-9b4f-cefafc028e7d", "name": "l(r:p1rdt7551lv-p1rlv16115)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c4d7ee3-fc5d-4a17-a717-3d6b6d5a67ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52d1b79d-5c6b-4b44-9998-600c6debd999"}}}], "length": {"value": 0.0259188, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3b54588d-c6e8-4042-a694-8f87967ab8fa", "name": "l(r:p1rdt7551lv-p1rlv16157)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c4d7ee3-fc5d-4a17-a717-3d6b6d5a67ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6efff4f7-c67b-4cfb-a72d-30b6616825b1"}}}], "length": {"value": 0.0259188, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b929915f-3f5c-4a02-a605-4d4873b39119", "name": "l(r:p1rdt7552lv-p1rlv16116)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f5d6708-cef4-4aac-9fa0-c738953c788f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "972f8088-b67b-47d0-a86f-49179dfb1c92"}}}], "length": {"value": 0.0159262, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c71cbb71-235a-44d4-b728-c68916a4acd2", "name": "l(r:p1rdt7552lv-p1rlv16197)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f5d6708-cef4-4aac-9fa0-c738953c788f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "92a37082-36d4-4eca-95e4-88dbcacd6db5"}}}], "length": {"value": 0.0159262, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ec088b7a-ade2-41ea-864c-57e6fd14b91d", "name": "l(r:p1rdt7553lv-p1rlv16117)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7a672b2-d127-4fb5-8cc4-8115b8ef3f60"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "204899ec-81e4-4a72-bf70-69b3428a49a1"}}}], "length": {"value": 0.0305725, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a08734c0-f8c0-4514-bd5a-0a14ae6698f8", "name": "l(r:p1rdt7554lv-p1rlv16118)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86a6d184-d883-4e27-aee5-b89c82163284"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bca0b3a0-d4cb-4a4a-9b14-aa23d9e5e5fe"}}}], "length": {"value": 0.0431821, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "104b928d-0e37-4538-86e0-e3ce3f7cc27b", "name": "l(r:p1rdt7554lv-p1rlv16139)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86a6d184-d883-4e27-aee5-b89c82163284"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c840cf3f-be15-448b-8c03-8942c586b135"}}}], "length": {"value": 0.0529135, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "abbad3a6-93e2-42c7-a931-18251d488605", "name": "l(r:p1rdt7554lv-p1rlv16201)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86a6d184-d883-4e27-aee5-b89c82163284"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68aa5cc5-f6bf-4417-8653-747c56b37b5e"}}}], "length": {"value": 0.0637427, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f7fbf2cc-e76a-457d-ae93-ed19e5ec96f4", "name": "l(r:p1rdt7554lv-p1rlv16209)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86a6d184-d883-4e27-aee5-b89c82163284"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf413742-18c8-483d-b8f1-f125f95323da"}}}], "length": {"value": 0.0332888, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "da4e7bb9-ac02-48a7-8773-f803a9aa7a98", "name": "l(r:p1rdt7555lv-p1rlv16119)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0de9c581-b78b-44d6-8693-59b995e2a3bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0d6e608-d5bf-40d6-9efd-f3b0922e7d77"}}}], "length": {"value": 0.0197555, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "55ec2ab9-796c-472c-8a9d-64fbe049e120", "name": "l(r:p1rdt7559lv-p1rlv16124)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b593ec6-e1e3-48c2-b352-f7966f206aa9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6da4b2d0-66c7-43fb-9aab-3bbac03aa989"}}}], "length": {"value": 0.04179700000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a4d01ff6-e324-423e-8097-8fe2dde83c0c", "name": "l(r:p1rdt7561lv-p1rlv16126)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05e30abd-3c40-4dbd-9261-ca8a8abd9c56"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd41f55a-4b5d-4c19-9787-801072b3b946"}}}], "length": {"value": 0.014319000000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "54c5bc8b-b799-4216-ab3d-e01ebf98fd85", "name": "l(r:p1rdt7561lv-p1rlv16133)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05e30abd-3c40-4dbd-9261-ca8a8abd9c56"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "102b9460-ea9a-4099-b16f-40b8fdf99ef7"}}}], "length": {"value": 0.024141, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "08cb3840-ba64-4648-ac83-a9a0a208e7ba", "name": "l(r:p1rdt7564lv-p1rlv16135)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7588b3b-f54c-483d-b354-b9908483019a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "676de1a3-2dfd-4faa-a057-7739e825d136"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "eb5f1aa9-9ff8-40fd-8116-08d5bd2f5b05", "name": "l(r:p1rdt7570lv-p1rlv16146)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2b3b9e1-3d98-44c1-bd38-9325623a1553"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6d21c357-1033-45e1-84a0-b82ceafe6ab8"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "7d8cd8ac-49ed-4d0d-80aa-a56a0a98e204", "name": "l(r:p1rdt7572lv-p1rlv16149)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69bf048e-54cd-4e41-a23e-485b0cd98fae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b15792ca-a6bd-47e5-8c67-5c3076174848"}}}], "length": {"value": 0.0827433, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f9ca3f6b-08b6-438b-9f86-993d7fa5dd9e", "name": "l(r:p1rdt7572lv-p1rlv16200)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69bf048e-54cd-4e41-a23e-485b0cd98fae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1aacea55-115d-46c3-9590-725cf5040f38"}}}], "length": {"value": 0.0976866, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a44b7dcd-89ab-4bca-aa5d-4fbe0e9b4b31", "name": "l(r:p1rdm16630-p1rlv16158)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33a848c7-076e-4025-863b-ce9151bcc3ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b85e180a-8eb4-4acc-a816-d99758cc16ea"}}}], "length": {"value": 0.0621197, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c4c0ee7e-a839-4490-b368-ac306b9905e2", "name": "l(r:p1rdm16630-p1rdt7572lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69bf048e-54cd-4e41-a23e-485b0cd98fae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33a848c7-076e-4025-863b-ce9151bcc3ac"}}}], "length": {"value": 0.0168609, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ffb75304-be2a-4021-9df7-22035d0c632a", "name": "l(r:p1rdt7574lv-p1rlv16156)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a742708-0f8b-42d0-a977-b5ce5e36a042"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "74edd9e9-24a5-4b36-8ca8-24ef2fa3e972"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "c9189682-4127-4793-8dde-134bd7a7291f", "name": "l(r:p1rdt7576lv-p1rlv16168)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56b05024-7907-458d-a5c3-0e54ffbabdb5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fb5abb7-dd79-49aa-9185-88a90bb45bc7"}}}], "length": {"value": 0.0685246, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4d947146-90b2-45ec-bc1d-69b52e20c50d", "name": "l(r:p1rdt7579lv-p1rlv16177)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d00b7fe-0384-4c12-a0cf-8895458d3b80"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbbe8401-53a1-4ce7-9ce1-02f547055d95"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "e1f41f9d-38bc-4e6e-be1e-8944e4b9739e", "name": "l(r:p1rdt7588lv-p1rlv16206)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abc940b0-c9f5-4582-adaf-ad7f4a79a35f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ca42395-8d67-4e83-80ec-159cacb490f8"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "607adf52-d8db-4ffb-af17-e06b4b4fbc79", "name": "l(r:p1rdt7589lv-p1rlv16210)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53e9cf92-1c91-428f-bdff-64257257ad5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fd05f3c-df77-45bc-8686-458b681a3d08"}}}], "length": {"value": 0.0134298, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a5726d13-5f87-414f-b712-c0bdc1ced439", "name": "l(r:p1rdt7589lv-p1rlv16235)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53e9cf92-1c91-428f-bdff-64257257ad5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56b91b3f-dfdd-41bf-9d2e-a8183077c752"}}}], "length": {"value": 0.0134298, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "83719399-628f-43ed-9d51-afa6375509c4", "name": "l(r:p1rdt7598lv-p1rlv16221)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff1e0d26-d845-43c3-9aaf-01d1c007b9a1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9761003-33fa-482a-967b-b508ab67c19f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "28e30c05-116b-48f0-b762-f119ac7be7c2", "name": "l(r:p1rdt7599lv-p1rlv16222)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d838502-3769-4d70-839b-26fd628ce478"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4809afc1-2d3d-491d-80e5-9cd4e8da08f2"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "5b38ef2e-a672-495a-8c15-b228d75558b7", "name": "l(r:p1rdt7605lv-p1rlv16228)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3488ff0-696f-4180-bc70-41ff37f9c365"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8767650-39c5-4d4a-80ce-af408c246599"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "ec9d0c28-58f8-4219-86b8-4d3fe6dc4315", "name": "l(r:p1rdt7612lv-p1rlv16239)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fdfea70-187a-4bbc-ba3f-69cb74c4d5c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9642fa30-e5f7-42f1-8fda-ab75a265d25a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "ea4ba13f-ec5f-47ae-a475-1ff409bfad77", "name": "l(r:p1rdt7615lv-p1rlv16242)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "269e9ba5-bc54-4cbd-9140-4b1bea74fc53"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e82036d9-e6c8-42c3-b45b-30bef6902bbc"}}}], "length": {"value": 0.0438853, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "66f3614c-b762-431c-bba3-5445c8ac5bc5", "name": "l(r:p1rdt7615lv-p1rlv16261)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "269e9ba5-bc54-4cbd-9140-4b1bea74fc53"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "978533ca-ef57-4cb6-9e7f-b3c6d1bbd7d5"}}}], "length": {"value": 0.0039062, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "65534143-6fae-4784-bacd-558a8b721a34", "name": "l(r:p1rdm16694-p1rlv16253)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65458dd3-50e0-48d3-a0db-0015707d3cea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "268549c6-0c8b-44ac-b933-316b36645366"}}}], "length": {"value": 0.00713936, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "33912f3d-e42a-475f-8eb4-4cf6ed16c0e4", "name": "l(r:p1rdm16694-p1rdt7616lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6af13868-ecb1-4110-be3f-537741287035"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65458dd3-50e0-48d3-a0db-0015707d3cea"}}}], "length": {"value": 0.04559330000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1e096ee0-46cf-48e0-a5c7-6ea777f3864e", "name": "l(r:p1rdm16695-p1rlv16270)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83d31d7a-8900-4f2e-9183-8a10f07e2bdd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c620d4b9-a849-4bf6-b108-118836866602"}}}], "length": {"value": 0.00252406, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "fe55db9e-e385-467e-b205-95aee0e835b4", "name": "l(r:p1rdm16693-p1rlv16243)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "766647d4-7c3c-4058-b30c-dbc593b88ecb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20818cc7-617e-4ab7-8f7c-31eea6496a02"}}}], "length": {"value": 0.00264008, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "80ef82e9-89e1-4cdc-96a2-6fa1ad7525c5", "name": "l(r:p1rdm16693-p1rdm16695)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83d31d7a-8900-4f2e-9183-8a10f07e2bdd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "766647d4-7c3c-4058-b30c-dbc593b88ecb"}}}], "length": {"value": 0.0423278, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "cfe5162e-a033-4a41-818f-eae382c104ad", "name": "l(r:p1rdm16695-p1rdt7616lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6af13868-ecb1-4110-be3f-537741287035"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83d31d7a-8900-4f2e-9183-8a10f07e2bdd"}}}], "length": {"value": 0.0158248, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "2d347746-0969-4a8a-b986-c40ef4f4c015"}}}}, {"uuid": "81f9870b-57d8-46dd-8268-9ddfab130818", "name": "l(r:p1rdt7617lv-p1rlv16244)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4be4af94-fee7-40d6-9061-9a0fe0e7377e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0164339-acc1-4b95-aa31-3af42cf943f7"}}}], "length": {"value": 0.0112872, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "713a3da4-b5d5-4fbf-98a9-8452a1617c74", "name": "l(r:p1rdm16697-p1rlv16255)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d1fb8eb-57aa-4366-afe5-b79174f3a4c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04647fad-19dc-4ed8-8820-aa312674145c"}}}], "length": {"value": 0.0169738, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c2ff74fe-7d8e-4aeb-8e9c-f1f0a2cb7fde", "name": "l(r:p1rdm16697-p1rdt7617lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4be4af94-fee7-40d6-9061-9a0fe0e7377e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d1fb8eb-57aa-4366-afe5-b79174f3a4c7"}}}], "length": {"value": 0.0068104, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bac616b7-1504-4880-87c4-0dbc21ee3814", "name": "l(r:p1rdm16699-p1rlv16252)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "795f4296-7c54-4e96-8468-52903af39708"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5c6a5f39-0654-4e73-8050-c6c4ad9d54e6"}}}], "length": {"value": 0.0353234, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e02a1459-a30a-43eb-9142-957ff82ef685", "name": "l(r:p1rdm16698-p1rlv16245)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acb015a8-a9f8-492b-ab3f-b107bd956f91"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3783c838-b72e-42cd-8b0b-3005bca3cf5e"}}}], "length": {"value": 0.0114502, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "47db165b-0d9a-4146-8789-b79d73c2dd6c", "name": "l(r:p1rdm16698-p1rdm16699)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "795f4296-7c54-4e96-8468-52903af39708"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acb015a8-a9f8-492b-ab3f-b107bd956f91"}}}], "length": {"value": 0.0170042, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ea0f86b2-7d46-447e-afb9-c85eb9d4acac", "name": "l(r:p1rdm16699-p1rdt7618lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49f37435-54fc-42b4-baba-94f0611c8c76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "795f4296-7c54-4e96-8468-52903af39708"}}}], "length": {"value": 0.0170124, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f5a0982c-76ee-4c76-b17b-db2b29132c0a", "name": "l(r:p1rdm16700-p1rlv16267)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73030a97-0574-4802-80d1-14fefeafa63a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19aeb510-ac0e-4279-8db0-8de282beccc8"}}}], "length": {"value": 0.0129138, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ab960f3a-b750-4490-8919-1b78f1ee81f9", "name": "l(r:p1rdm16700-p1rdt7618lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49f37435-54fc-42b4-baba-94f0611c8c76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73030a97-0574-4802-80d1-14fefeafa63a"}}}], "length": {"value": 0.0510234, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "aef758c3-6056-49d2-8a02-60b50c63bd6e", "name": "l(r:p1rdt7619lv-p1rlv16246)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a205379-48f9-444c-baf8-dc84fc9c6d8a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd2dc2db-787a-4732-bae4-01186082a92d"}}}], "length": {"value": 0.0487659, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1ba0dfcc-9d4f-4d9d-9b25-d4ac783d610a", "name": "l(r:p1rdt7620lv-p1rlv16247)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af91c50-929d-4ac6-9272-7c44d17a0094"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8d5e9b7-dc95-41f9-8547-99d5e2eba874"}}}], "length": {"value": 0.029204400000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9a074422-3751-46be-a791-1c5831090b87", "name": "l(r:p1rdt7621lv-p1rlv16248)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60f0bddf-6e4b-495c-a98d-f3940d69a5e9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "feb24768-feab-40f0-acc3-0b2bb500133a"}}}], "length": {"value": 0.0226951, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8c4067c2-4a24-4294-b0b5-9e078686ce14", "name": "l(r:p1rdt7624lv-p1rlv16256)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e2075fb-9691-447e-9a73-f88649310bc1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32a9302f-2d40-4c2a-bde9-e4039694fed7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "0179bbe7-ed91-420f-bc7e-556355621ed5", "name": "l(r:p1rdt7625lv-p1rlv16257)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6b1e3b6-ce3a-4ad6-a046-6608530b2ec2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "935c99a6-bef6-4417-872c-0685011c440c"}}}], "length": {"value": 0.08197240000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b7d74205-f9f2-4629-b005-d28349a3ee52", "name": "l(r:p1rdt7626lv-p1rlv16260)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56f8eed1-77ae-4d65-80aa-7ae148350333"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdf35585-e2b3-4463-a6a8-acb352f25003"}}}], "length": {"value": 0.0157324, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "faadfdae-2d72-4662-91e7-ec1f7654ef6b", "name": "l(r:p1rdt7626lv-p1rlv16269)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56f8eed1-77ae-4d65-80aa-7ae148350333"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc746539-662a-4fe4-8774-6ba2dc538118"}}}], "length": {"value": 0.00987847, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5edfcfe0-2c44-4832-938e-e09b4621e7c1", "name": "l(r:p1rdt7627lv-p1rlv16262)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90d8891c-6e6d-46b9-8f88-acc9453c6541"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2797febc-f5e7-4cb3-b26f-ace990dc6920"}}}], "length": {"value": 0.00420024, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "18404b85-1ac1-4964-b5a4-69db35c99ef9", "name": "l(r:p1rdt7630lv-p1rlv16266)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ad2599f-313b-49c6-abaa-19177e1a9edc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8835446-b333-4be9-96bd-57ff9d01ebd3"}}}], "length": {"value": 0.0649914, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9c3cc8d2-c149-4fa9-8e26-1cfb3d5840fe", "name": "l(r:p1rdt7631lv-p1rlv16268)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4861056b-b634-4900-94bb-d6c995387351"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba6ebe7f-b6b9-4f89-8bbf-7bffd63e10ef"}}}], "length": {"value": 0.0412806, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "fe7937ea-1d97-4b06-ae00-05043b6f5450", "name": "l(r:p1rdt7699lv-p1rlv16416)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bfa76dc8-4007-4e52-9692-2eec7cb574e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f58421d6-268b-417f-a579-c9c51d010697"}}}], "length": {"value": 0.079141, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e329d231-586c-4da4-be1c-635869501cb7", "name": "l(r:p1rdm16862-p1rlv16395)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e60bfe9e-d2fa-4576-87f3-0a866b88d07d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d908890-4fe4-4349-92de-464c4165b185"}}}], "length": {"value": 0.0592066, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "468c39e1-9b75-4323-be99-3513b80c5ba1", "name": "l(r:p1rdm16862-p1rdt7699lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bfa76dc8-4007-4e52-9692-2eec7cb574e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e60bfe9e-d2fa-4576-87f3-0a866b88d07d"}}}], "length": {"value": 0.0187021, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ca527da2-14ed-422f-b70c-1bc7bd4d4a7e", "name": "l(r:p1rdt7701lv-p1rlv16397)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0cc95d09-c799-488e-81e8-50326a7da1ea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "323373a9-8e7d-4fb4-8970-dcc0e6d26c98"}}}], "length": {"value": 0.0805765, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f9812016-b945-4e02-8acf-7b54729433c8", "name": "l(r:p1rdt7704lv-p1rlv20070)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ef392d6-b408-4a7f-8a67-9fe43e1df582"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "571a4c92-95b6-4bc0-a25d-0d9239a41a89"}}}], "length": {"value": 0.0912722, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "69240808-930b-4994-9d23-dee6955da16c", "name": "l(r:p1rdm16872-p1rlv16401)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0797f1d0-3499-4f88-a749-fc576240f791"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eeb598c2-f0b9-44df-bfaa-be66e4dc3920"}}}], "length": {"value": 0.0257854, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "18b08e77-eb01-4b55-b1ce-98e572b7dd24", "name": "l(r:p1rdm16872-p1rdt7704lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ef392d6-b408-4a7f-8a67-9fe43e1df582"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0797f1d0-3499-4f88-a749-fc576240f791"}}}], "length": {"value": 0.0193937, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7cba66ff-a6ee-4381-9e47-2a5af2de3377", "name": "l(r:p1rdm16873-p1rlv20068)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5e00667-6368-49d3-a5dd-c574c79dba21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0b689f0-d4b1-4419-bff8-f72436625c60"}}}], "length": {"value": 0.0406184, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ba8749a8-823d-4c50-9058-f01580cfa960", "name": "l(r:p1rdm16873-p1rlv20069)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5e00667-6368-49d3-a5dd-c574c79dba21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f0e3c74-2d63-4612-b0e5-d986ebee0086"}}}], "length": {"value": 0.0750315, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9621505b-497f-4f4e-b57f-a04130b6eca0", "name": "l(r:p1rdm16873-p1rdt7704lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ef392d6-b408-4a7f-8a67-9fe43e1df582"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5e00667-6368-49d3-a5dd-c574c79dba21"}}}], "length": {"value": 0.019391500000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e7f8fc5c-5a80-4393-8e10-ac437b20b61d", "name": "l(r:p1rdt7712lv-p1rlv16412)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59a62487-c709-428e-9e97-c7c285a1305c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99f97a6b-4e94-4a35-ad00-12e7004ab5e3"}}}], "length": {"value": 0.0485398, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f0906201-838f-44bd-962b-5a532e582278", "name": "l(r:p1rdt7718lv-p1rlv16422)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6d10a4e-e7bc-4448-bca3-a5f2117b6198"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f367b63c-c4cb-4810-a270-8bd0153b7b32"}}}], "length": {"value": 0.013767300000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6fa6e077-a768-476b-84c5-2aa32a00b492", "name": "l(r:p1rdt7718lv-p1rlv16424)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6d10a4e-e7bc-4448-bca3-a5f2117b6198"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2242f1c-542f-4c1f-b3e6-19482cccde8d"}}}], "length": {"value": 0.013767300000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "067decd6-dc2e-405c-b604-7300ea1905a2", "name": "l(r:p1rdt7735lv-p1rlv16445)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96dcd934-01a0-4719-89bc-a18430edf179"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e090544-3c8e-4716-9dae-0b311a1017ea"}}}], "length": {"value": 0.0284282, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d86ce606-0132-488e-ba44-92843bfb8d12", "name": "l(r:p1rdt7790lv-p1rlv16570)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ed564b5-8d49-4ff7-94c2-b245981472e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53d578d8-8492-471b-8f66-233e489a3652"}}}], "length": {"value": 0.0553998, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7ea5b970-dc67-44e2-af2f-76936ea99183", "name": "l(r:p1rdt7954lv-p1rlv16905)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9dd5bb5-1410-4635-8a85-d23d7c3e55ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7578563f-d4b3-423b-a8f5-3ee91a042d19"}}}], "length": {"value": 0.0850821, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "00df3659-93b5-43ea-a55e-a0893faccc10", "name": "l(r:p1rdm17416-p1rlv16882)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e982887d-97c6-4af5-b536-a15a372b3379"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4faf40b9-9ade-45b5-ade8-3f1833605cd1"}}}], "length": {"value": 0.09884780000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "729ab8bb-81b7-460d-8b0e-e4f5ef25eda6", "name": "l(r:p1rdm17416-p1rdt7954lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9dd5bb5-1410-4635-8a85-d23d7c3e55ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e982887d-97c6-4af5-b536-a15a372b3379"}}}], "length": {"value": 0.0184307, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ef9a2339-09f7-486b-8e23-0b908af565b6", "name": "l(r:p1rdt7973lv-p1rlv16912)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3a96167-4b09-49c9-baf7-4fb588ecb002"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2308dc3-d10b-4049-862d-caf3356fa9a7"}}}], "length": {"value": 0.0637175, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2719d040-2a20-4bbc-bbf1-d5f6272f6310", "name": "l(r:p1rdt7973lv-p1rlv16988)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3a96167-4b09-49c9-baf7-4fb588ecb002"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11a633b0-2b09-4c66-94d4-d1c24cdd9cf5"}}}], "length": {"value": 0.0681669, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7cb3929d-dcf6-4fa6-bf71-8d2d79fbacd7", "name": "l(r:p1rdm17505-p1rlv16904)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53ed549a-9c24-4bdd-9e40-aee5308d8120"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c570ef7-c483-4c1e-b0fd-8712e8e9a7cd"}}}], "length": {"value": 0.0396092, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "792c1524-361f-42ca-81a5-8f88a601bd78", "name": "l(r:p1rdm17505-p1rdt7973lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3a96167-4b09-49c9-baf7-4fb588ecb002"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53ed549a-9c24-4bdd-9e40-aee5308d8120"}}}], "length": {"value": 0.0168466, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1313795b-a5f9-4cc6-a9c8-7943979110f3", "name": "l(r:p1rdt7983lv-p1rlv16919)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb63be48-94ec-4c9f-9991-77892e14171b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07e01053-37f3-4b9f-a9f1-d51bccd29803"}}}], "length": {"value": 0.079259, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "85650fc1-1735-4e05-8f26-86c5ca8437b9", "name": "l(r:p1rdt7983lv-p1rlv17033)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb63be48-94ec-4c9f-9991-77892e14171b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfa28657-cd8e-4700-a189-83e021f77bee"}}}], "length": {"value": 0.0492948, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0f5baa05-57eb-4dcd-b077-ae2d13649e82", "name": "l(r:p1rdt7986lv-p1rlv16922)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "415fe6e9-953e-40f6-8ae8-43834e4e6ce4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce315d98-1556-429b-aebb-0c868892396a"}}}], "length": {"value": 0.0143418, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "001d627b-af02-488f-b9c8-23280b783daa", "name": "l(r:p1rdt7986lv-p1rlv16957)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "415fe6e9-953e-40f6-8ae8-43834e4e6ce4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7dff1455-5154-429f-a33f-044d8501281d"}}}], "length": {"value": 0.0453768, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6476ae7e-8f41-498c-9da2-84e326f9d60a", "name": "l(r:p1rdt7986lv-p1rlv17063)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "415fe6e9-953e-40f6-8ae8-43834e4e6ce4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19130741-0fe1-4a12-8a55-96355609bccb"}}}], "length": {"value": 0.0371136, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e0da39bf-f183-4b18-9021-71a39d01f9bd", "name": "l(r:p1rdt7988lv-p1rlv16926)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94f12107-697c-4278-95e0-32b6eb49fdb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ba1d053-4462-4eb4-aca6-5ede38aa283c"}}}], "length": {"value": 0.00743277, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "150161df-4909-484b-95b0-d6b3d384dbc8", "name": "l(r:p1rdt7988lv-p1rlv17106)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94f12107-697c-4278-95e0-32b6eb49fdb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5439f343-8176-4d92-99d4-bb9209817f6b"}}}], "length": {"value": 0.00743277, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b7fe8781-6590-4253-9abb-c7288b33a95b", "name": "l(r:p1rdt8012lv-p1rlv16992)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5b22c57-7912-4e9f-9b06-6a8ff706a58d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57e8aa34-3967-4f22-a978-cb513c49c153"}}}], "length": {"value": 0.109333, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "93bde77a-daea-4cd1-9aac-96608150fd7e", "name": "l(r:p1rdt8012lv-p1rlv17069)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5b22c57-7912-4e9f-9b06-6a8ff706a58d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd48a076-5f8f-426a-b294-183700d1a123"}}}], "length": {"value": 0.0628588, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c75878bb-a8e9-45f7-ac9f-3112ab4daa2e", "name": "l(r:p1rdt8015lv-p1rlv17001)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6c5d7ff-cfcd-4b30-98db-eb44a95d6841"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f23214ee-3032-4403-9084-8117e89cb1cf"}}}], "length": {"value": 0.00814411, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4a06edff-3ac9-477f-afd1-857950e98149", "name": "l(r:p1rdt8015lv-p1rlv17028)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6c5d7ff-cfcd-4b30-98db-eb44a95d6841"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "213e6d98-ad57-4034-b2d0-4b096554cac2"}}}], "length": {"value": 0.00814411, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "963a379d-4526-40c4-a92c-040fcd1db98c", "name": "l(r:p1rdt8034lv-p1rlv17059)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "972fe574-f88e-4a8d-8845-d5baa2f378a7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "92aff718-b70f-4ea4-b38b-fae69a470c58"}}}], "length": {"value": 0.0530471, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "39ed0258-6338-449e-a516-59e9a08220e0", "name": "l(r:p1rdt8149lv-p1rlv17319)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9951633b-4311-4ca2-9316-3801be13fe97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9778ed5-f0c0-44de-b0d4-60659a54fa3b"}}}], "length": {"value": 0.0160827, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cee2f792-d80f-4b98-a645-57496b1a1a4e", "name": "l(r:p1rdt8149lv-p1rlv17334)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9951633b-4311-4ca2-9316-3801be13fe97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4970bc03-bc57-4a42-b0cb-66002af1709e"}}}], "length": {"value": 0.016006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1df0e133-12a9-410c-ac98-560dfc4918f0", "name": "l(r:p1rdt8150lv-p1rlv17320)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cd1ae47-6aaa-4b57-ba44-1e74f6ea54b7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79991b02-c0f1-4b9b-a55e-e9b4ff7c17d9"}}}], "length": {"value": 0.063086, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "815c3299-4558-40b9-b5fe-d5f0c27c11d7", "name": "l(r:p1rdt8150lv-p1rlv17326)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cd1ae47-6aaa-4b57-ba44-1e74f6ea54b7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ceb2d77-2da7-44df-9f28-69ed35835775"}}}], "length": {"value": 0.063086, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "499d0139-fa5c-45de-864f-e28786ab80fa", "name": "l(r:p1rdt8151lv-p1rlv17321)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a8deb5-b46b-4d4c-876c-b44b2258a6fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "00ed745d-78ae-47f6-b6ef-4edf8794ca6a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "4d608ad4-d94a-4b0b-8fcd-3c08ae50178c", "name": "l(r:p1rdt8151lv-p1rlv17321)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "00ed745d-78ae-47f6-b6ef-4edf8794ca6a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94ce8ee2-6f57-407a-93e9-c06f79d66262"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "4dceb5ed-b8a7-4331-90f0-5f93186eeaba", "name": "l(r:p1rdt8151lv-p1rlv17321)_s2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94ce8ee2-6f57-407a-93e9-c06f79d66262"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce41ac7c-06c5-435a-957d-c9dda83c1893"}}}], "length": {"value": 0.09433530000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d09084bb-a89a-4254-a73c-e94d3dc90fbd", "name": "l(r:p1rdt8151lv-p1rlv20188)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a8deb5-b46b-4d4c-876c-b44b2258a6fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abb24254-be79-45d4-8d9b-246b3e89c00f"}}}], "length": {"value": 0.00615959, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4ef03455-4b06-4b8f-af90-475cc6a09a60", "name": "l(r:p1rdt8153lv-p1rlv17325)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a542ca5-b24e-44dc-8b68-c00aa024afad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b96606c-9336-4299-be8d-295c84943a9d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "23108ceb-470b-432b-b6c3-701d156a5397", "name": "l(r:p1rdt8154lv-p1rlv17328)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32fefbef-e10b-4758-8c2e-ccafad49aa5d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a43eb022-d5e0-47c8-aa36-6ca0d212ab07"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "36ad5faf-d994-41eb-afb8-9a4fb8edcf6c", "name": "l(r:p1rdt8155lv-p1rlv17329)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51812cd8-eec8-4862-8413-d25a7e9862dc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61ef37c1-f14f-4b79-a428-d51a6f0d076a"}}}], "length": {"value": 0.0793038, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b52124cd-a5c9-4f18-9f6d-79b8143d4cef", "name": "l(r:p1rdm17903-p1rlv17330)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb2a5041-28a1-4fda-905b-caf53ebbefe3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48ad7bb0-8dd7-457a-b77d-6db2071c2fe7"}}}], "length": {"value": 0.0025319, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "11874623-6a90-44c5-b716-1180ab27ebdb", "name": "l(r:p1rdm17903-p1rdt8155lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51812cd8-eec8-4862-8413-d25a7e9862dc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb2a5041-28a1-4fda-905b-caf53ebbefe3"}}}], "length": {"value": 0.0391228, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a670c5be-e502-4ee5-bab3-d6830776dd9c", "name": "l(r:p1rdt8157lv-p1rlv17333)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa6d4429-8a95-4ebd-9e3a-9867734245bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33b66eb9-3b21-4f92-b19b-6a0eef4134d8"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "3c168ea4-60f1-40d7-9105-c60ebe5c0919", "name": "l(r:p1rdt8159lv-p1rlv20480)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1dd4660-3cd0-4709-b1ef-1c598e5e39fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5d0a174-d49d-4c7e-a669-092f6408edf4"}}}], "length": {"value": 0.0224012, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "42b10885-9f84-40fb-8096-ecdeabc0172c", "name": "l(r:p1rdm17907-p1rlv17336)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3484e698-3a4e-4a88-aaa3-1dc88cd9ac89"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b645969-9136-42a9-b5ac-7d2f1ff71959"}}}], "length": {"value": 0.0155741, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "711295b2-6d63-413f-8284-ba2877d64e97", "name": "l(r:p1rdm17907-p1rlv20492)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3484e698-3a4e-4a88-aaa3-1dc88cd9ac89"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7af262b7-285c-4d06-b7ff-2f2a1971055a"}}}], "length": {"value": 0.049942, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "daa257f3-0092-4324-ba2d-11ec7a94a4a1", "name": "l(r:p1rdm17907-p1rdt8159lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1dd4660-3cd0-4709-b1ef-1c598e5e39fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3484e698-3a4e-4a88-aaa3-1dc88cd9ac89"}}}], "length": {"value": 0.018672500000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2cbdeb9d-3636-4393-9326-b0240390e325", "name": "l(r:p1rdm17908-p1rlv20455)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6112cc26-bc37-4c72-8ef6-cd88f1296693"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8934db59-0c39-4838-9f8c-59a563cd9d54"}}}], "length": {"value": 0.0215008, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "06e87fff-fd19-45b8-bb9b-8cd0c6413c5a", "name": "l(r:p1rdm17908-p1rdt8159lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1dd4660-3cd0-4709-b1ef-1c598e5e39fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6112cc26-bc37-4c72-8ef6-cd88f1296693"}}}], "length": {"value": 0.0175631, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9a093498-1758-4c33-8c70-ea251e449258", "name": "l(r:p1rdt8160lv-p1rlv17337)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "232fed6b-fe0f-4a44-93e9-e6675b50c39c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5d7049e-9d30-474c-9033-3ad9b4487f7a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "259d0df0-c158-431c-8a14-d3db5f371846", "name": "l(r:p1rdt8161lv-p1rlv17338)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac7e489e-7249-4702-9ed6-131cad34500f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "331389ab-5d04-4648-83b4-3043198c774f"}}}], "length": {"value": 0.05601040000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "56875cf5-044e-43c9-b940-eee8bd16a486", "name": "l(r:p1rdt8346lv-p1rlv17702)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9560197a-21d1-4601-8bcb-213df4844f4a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7acb4e7d-cb06-4848-952d-7c68bb34b6db"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "e6dddecc-acad-4d45-849a-d67e98fe7205", "name": "l(r:p1rdt8405lv-p1rlv17781)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "408d5d7b-fc71-46bb-8de0-2d4e628c29b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a52db2ff-b782-40c1-828a-c65f6929b2fc"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b38ef92b-b5a5-4354-a862-4ff2cfcaf0e2", "name": "l(r:p1rdt8408lv-p1rlv17787)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3fe0f77-a7c1-48e3-94aa-30b69f20ca65"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c9c1d9f-eeff-454f-b3d0-7e7de837694c"}}}], "length": {"value": 0.030519200000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d2fdb455-533e-494f-b3ae-7a6f434a6456", "name": "l(r:p1rdt8408lv-p1rlv18044)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3fe0f77-a7c1-48e3-94aa-30b69f20ca65"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b40fac8c-a99b-4baa-940a-26565ba7d62b"}}}], "length": {"value": 0.030519200000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2cccc34f-8ec9-4a07-94e6-5ea9394c8395", "name": "l(r:p1rdt8414lv-p1rlv17798)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fca92353-c013-4c41-8507-ec8704410834"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9dba02d-086c-4906-9c6f-86532e3384c0"}}}], "length": {"value": 0.0626486, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3fa99df5-af3e-4d19-92fe-6c6b8fa2435f", "name": "l(r:p1rdt8422lv-p1rlv17810)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfe35c35-8164-4825-81e3-10a2ece2cb27"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3887a879-0783-4703-8a24-32b7e3b4f39d"}}}], "length": {"value": 0.064621, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "29fcd1b6-7f66-4926-8f32-6b14ca47aa39", "name": "l(r:p1rdt8422lv-p1rlv17847)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfe35c35-8164-4825-81e3-10a2ece2cb27"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f7776e4-a81f-48d2-b3c0-d70bfa48164e"}}}], "length": {"value": 0.114619, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6a2c3743-a96c-4193-afff-9f66a9993e4a", "name": "l(r:p1rdt8422lv-p1rlv17876)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfe35c35-8164-4825-81e3-10a2ece2cb27"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75e55237-b847-4fb7-a141-a0771bd868c6"}}}], "length": {"value": 0.0889709, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1cfd7122-29e2-4593-8a29-d37c7bab1574", "name": "l(r:p1rdm18545-p1rlv17961)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7421f5c-bf5c-4d01-aa14-ba657f242080"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2716887e-1701-4a78-805b-96da0781c7f8"}}}], "length": {"value": 0.07666780000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1fc0a354-eb4d-4fef-b7b3-9ac5204835bf", "name": "l(r:p1rdm18545-p1rdt8422lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfe35c35-8164-4825-81e3-10a2ece2cb27"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7421f5c-bf5c-4d01-aa14-ba657f242080"}}}], "length": {"value": 0.0192775, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6813915a-9540-4a06-8171-305ffaddeb8f", "name": "l(r:p1rdt8434lv-p1rlv17857)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdc5ef2a-c0d0-4702-b6c6-df08af1e8746"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0827675c-2467-403d-822e-5f74cd6296c5"}}}], "length": {"value": 0.0235179, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ae004d86-bb53-4a39-b217-28aba419df2a", "name": "l(r:p1rdt8436lv-p1rlv17877)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b24c9345-625f-499d-96cf-30b2de5839b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f44b0293-61e5-4054-b2d7-4a113df92b3c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "90848665-6e77-434a-9664-022c4b37b0ca", "name": "l(r:p1rdt8439lv-p1rlv17897)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a38f544-e250-4fc9-942c-946c5cde0a33"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f74f217-4765-406d-9646-d8f46377ef0a"}}}], "length": {"value": 0.0231504, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "615ebf6f-8bb0-491b-a80f-70ff9109b5c5", "name": "l(r:p1rdm18631-p1rlv17909)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6460e5c-839d-4f9e-b9d6-b187fddb9ab6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab733d49-bb36-4631-8824-1967f98f758a"}}}], "length": {"value": 0.055777700000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9d77603e-e62a-40c8-8d7b-5150e4e96a38", "name": "l(r:p1rdm18631-p1rdt8440lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "049362b4-49de-4e80-921e-ff763aaab2d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6460e5c-839d-4f9e-b9d6-b187fddb9ab6"}}}], "length": {"value": 0.017871200000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "48a7466b-1d73-416b-809a-83537dd3441d", "name": "l(r:p1rdm18632-p1rlv17969)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7633fe6b-a48b-4e7d-90e6-a38b8a861936"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ccaf70a-35d8-4f16-b632-e282fe30b5ca"}}}], "length": {"value": 0.018069200000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "19cb6fa7-25c3-47ca-a366-957be38b8701", "name": "l(r:p1rdm18632-p1rdt8440lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "049362b4-49de-4e80-921e-ff763aaab2d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7633fe6b-a48b-4e7d-90e6-a38b8a861936"}}}], "length": {"value": 0.0178577, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2caa96e4-c274-43dc-b1e4-5f11301d9ccf", "name": "l(r:p1rdt8441lv-p1rlv17912)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72c8f08a-0ba5-413e-a805-f9436b41ff29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3eb66d3-0271-4842-8893-9a58f64e0279"}}}], "length": {"value": 0.009300020000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "323d26e7-5b43-454b-a45c-aec7e307de9d", "name": "l(r:p1rdt8442lv-p1rlv17926)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b5ae28a-95f8-4023-aa23-36809fe96b10"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2812bbb1-0bb0-499f-a394-0995784bb7bc"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "186217d6-9a20-48aa-9949-c80f28bafe57", "name": "l(r:p1rdt8444lv-p1rlv17960)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "978920e8-edf9-4bee-85f9-45f4081ed0ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "215a5974-e23b-46f0-bde9-f5ad16fdfaf8"}}}], "length": {"value": 0.00946867, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a2666500-718c-4b6a-b104-d85550e22cdc", "name": "l(r:p1rdt8444lv-p1rlv18071)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "978920e8-edf9-4bee-85f9-45f4081ed0ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86917829-123c-4fda-9809-dc61430a9fef"}}}], "length": {"value": 0.00946867, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "af700dca-e6b2-417d-a811-cc93dc290724", "name": "l(r:p1rdt8445lv-p1rlv17962)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e0923da-550b-479f-b3d8-3e0320db6701"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec99daac-e0be-4ea1-ba4f-185d4943396d"}}}], "length": {"value": 0.07683860000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "529ee728-9a14-4ce5-bbf5-baa1001689c5", "name": "l(r:p1rdt8447lv-p1rlv17987)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5dbc3459-6a17-4075-899a-6aab16fb3ab7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0771ebfa-5eaf-4ae8-94f1-86de7a656f58"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "04dd8850-4fe7-4c15-8a87-50bc76145038", "name": "l(r:p1rdt8450lv-p1rlv18053)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b4216c8-9e99-446c-ad09-5a09f046dd59"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4aeda1c7-41be-43c8-82e5-d7a347db86a8"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "63c8dbef-8a8b-4ce8-95cf-6fc4728d963d", "name": "l(r:p1rdt8456lv-p1rlv18100)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d094b779-ebcc-4837-9ccb-31808e2a544b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4863d28-4ee2-479d-accb-60b54f472fe7"}}}], "length": {"value": 0.04190880000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "300dd493-34b4-4375-892d-eadd8fe22746", "name": "l(r:p1rdt8458lv-p1rlv18129)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e597d8da-e876-44a5-a109-1ce84527c557"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "115a848f-f6f3-48f0-9f33-5a9103f1a892"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "43c4c411-e502-46b8-9442-5f4d7dd2ea62", "name": "l(r:p1rdt8470lv-p1rlv18166)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "edb15d92-f98a-4fa2-8129-ad8a39e0dc0c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "431692e5-2917-41ea-aafc-96be180b7e27"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "be9ad055-8cbd-4405-8241-9bc60395472f", "name": "l(r:p1rdt8490lv-p1rlv18192)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a84e1424-7faf-4077-9461-b39460f10ef0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c3e08a8-ea88-423d-b361-69509f7ab8fa"}}}], "length": {"value": 0.0095095, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bdc387c3-9bdc-43d9-890f-0d718eba7c3a", "name": "l(r:p1rdt8490lv-p1rlv18198)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a84e1424-7faf-4077-9461-b39460f10ef0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a7cb078-af6c-4cd5-9aca-48f515f6e711"}}}], "length": {"value": 0.0095095, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f668b67f-606b-4d28-9cc3-1943007f22e4", "name": "l(r:p1rdt8492lv-p1rlv18197)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "127e4cc7-6413-4482-9ec3-40f8bde02d0c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5e240e8-b27d-4181-a7ee-a004d3f5c58a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "81b9170e-c68f-4cac-a3d4-fbc567e0a98c", "name": "l(r:p1rdt8802lv-p1rlv18960)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95a1a7c7-6055-47c9-a742-c1b81f6c7478"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9178fdee-311f-40f5-bdd6-9b474a05247e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "5c797127-ea67-442a-b638-200eacfd668c", "name": "l(r:p1rdt8805lv-p1rlv18967)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "715c92fa-2470-4869-8d5f-0b4f3f8360d4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eef4f0cf-6e51-45e1-8b6e-84171f7cbef6"}}}], "length": {"value": 0.0733915, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "dd30ae2e-bd36-4ebb-abb3-ba2b2c134191", "name": "l(r:p1rdt8898lv-p1rlv19157)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6ff626c-d2fc-4b97-9013-4fd544d946a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cf28b5d-d8d4-4883-a396-2d1ad9b70564"}}}], "length": {"value": 0.0657162, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "147a1cb3-41c2-49b8-8b56-b4683e957a72", "name": "l(r:p1rdm19752-p1rlv19149)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09d59048-6e1b-4f7f-b161-81163809eb25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67a4600d-65c3-40d7-ad28-e8e37ff77dcb"}}}], "length": {"value": 0.046789, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "0ca56993-e151-46ec-bc06-2732eef8e2a4", "name": "l(r:p1rdm19752-p1rlv19160)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09d59048-6e1b-4f7f-b161-81163809eb25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7c1d210-ee87-46c5-b408-ad221cbeed04"}}}], "length": {"value": 0.057637900000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "d4f9decd-9338-4453-85d3-5c8b5ac0490f", "name": "l(r:p1rdm19752-p1rdt8898lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6ff626c-d2fc-4b97-9013-4fd544d946a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09d59048-6e1b-4f7f-b161-81163809eb25"}}}], "length": {"value": 0.019358300000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "cb6ddaa3-2b16-42bd-bce5-bd8a267eab2f", "name": "l(r:p1rdm19755-p1rlv19166)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7664d29-bbc0-4465-a00a-82af048b86e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "994f6392-f4e5-4ff8-9eeb-5849cd035912"}}}], "length": {"value": 0.0880892, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "6a7bb342-4fcd-424d-861f-0ee25541d40f", "name": "l(r:p1rdm19755-p1rdt8898lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6ff626c-d2fc-4b97-9013-4fd544d946a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7664d29-bbc0-4465-a00a-82af048b86e5"}}}], "length": {"value": 0.0437869, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "f229b79a-47fa-4ab8-9ea2-b416d4caf8fc", "name": "l(r:p1rdt8901lv-p1rlv19161)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d53c0a2-78cc-4988-85a4-884ef039f5fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16df6b90-d049-4160-b148-b888e03acb82"}}}], "length": {"value": 0.0671759, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6bdd0d1e-8826-457f-a773-5a2a945a84ce", "name": "l(r:p1rdt8904lv-p1rlv19168)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e111e213-bcbe-42c4-b6ab-2c734ff5341c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f8c76ca-40ea-4f7d-8042-66edd484f065"}}}], "length": {"value": 0.045782800000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "741a9472-dbc2-427c-a02b-462c15f35f7b", "name": "l(r:p1rdt8904lv-p1rlv19174)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e111e213-bcbe-42c4-b6ab-2c734ff5341c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0fc7d43-4f82-4100-99bf-6e30e03e95ce"}}}], "length": {"value": 0.0128136, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "96ca1afa-d534-4724-8ecb-b6702cfd67b7", "name": "l(r:p1rdm19776-p1rlv19184)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b9386f2-376d-4439-a9a4-3eefc238dafe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50750ddb-80db-4d5f-bc62-4bbfc600a7ef"}}}], "length": {"value": 0.075847, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "72bd06c1-2522-4912-ab13-24cec5f2b774", "name": "l(r:p1rdm19776-p1rdt8904lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e111e213-bcbe-42c4-b6ab-2c734ff5341c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b9386f2-376d-4439-a9a4-3eefc238dafe"}}}], "length": {"value": 0.010418900000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a90947b1-4fd1-4387-bdff-d59c20a3fb90", "name": "l(r:p1rdt8905lv-p1rlv19169)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2777cc-f3fd-491f-a10b-4ed381cb948d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4e8183-9148-477e-aa1b-ff31a5324273"}}}], "length": {"value": 0.0299426, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "04d7afca-c271-4057-ab48-201ee8bcd8a3", "name": "l(r:p1rdt8905lv-p1rlv19171)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2777cc-f3fd-491f-a10b-4ed381cb948d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fffe26f7-c4cc-420e-ab17-754cb0d9e659"}}}], "length": {"value": 0.0502658, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "21e7a836-3ea5-407e-bd70-f3443102eebd", "name": "l(r:p1rdt8905lv-p1rlv19173)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2777cc-f3fd-491f-a10b-4ed381cb948d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21fec301-b67c-4042-a074-caf406c7f0b5"}}}], "length": {"value": 0.0431542, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7c1587be-1e8f-466e-8791-3a41354606c0", "name": "l(r:p1rdt8905lv-p1rlv19188)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2777cc-f3fd-491f-a10b-4ed381cb948d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47e24942-486d-46f1-a40f-0da5c93c013a"}}}], "length": {"value": 0.00975868, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4637e31d-b157-4290-a8cb-4596fb7db783", "name": "l(r:p1rdt8905lv-p1rlv19194)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2777cc-f3fd-491f-a10b-4ed381cb948d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7daa1d3-6249-447d-a260-65de5ec0a470"}}}], "length": {"value": 0.0629287, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3bca6f74-5988-47c8-a80c-3cd6b0a69bb6", "name": "l(r:p1rdt8911lv-p1rlv19183)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c306f79a-0240-465e-a486-d0f11614fc57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "89bde057-807b-415c-9135-267c6bf43c44"}}}], "length": {"value": 0.0132248, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7550f50f-c63b-48ad-8fdd-dc45f65120ce", "name": "l(r:p1rdt8911lv-p1rlv20296)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c306f79a-0240-465e-a486-d0f11614fc57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a8ae6dc-884d-48d8-9995-fe3936ad019c"}}}], "length": {"value": 0.0132248, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "418f522f-9800-4e1d-a31b-cf04a40a6664", "name": "l(r:p1rdt8915lv-p1rlv19189)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2fbbca23-6473-4344-ac2e-cc97078b3d8d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5fecc64a-4783-4ecb-a0d0-7e60d1cf6184"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "632311c1-925c-4de3-92fc-6b27efe14c9f", "name": "l(r:p1rdt8916lv-p1rlv19190)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d268e33-708d-4bae-8348-cad27fd0d81a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4aee02d4-8663-455b-a197-55b6b1470895"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "40f4ca55-ed5c-4973-971b-35cd67ba354e", "name": "l(r:p1rdt9075lv-p1rlv19667)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6752e8f4-9e37-476d-aec2-4a2fe7c1e2dc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33dcb037-4cc8-480f-aac4-bc95e54e165e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b4340e3d-5abb-4a2e-ab02-77baaf44385e", "name": "l(r:p1rdt9076lv-p1rlv19698)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdd64386-e256-47f8-8cef-1c933f993a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14b1ab4e-b22d-4a98-8131-fc72c923c735"}}}], "length": {"value": 0.055055700000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7a80ce41-b341-4153-b901-ce184294afbb", "name": "l(r:p1rdm20204-p1rlv19668)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd00c91a-01a8-4aad-b740-b06a654d631b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6427f66-2e22-40bb-83f1-2a8b1be9191a"}}}], "length": {"value": 0.0202803, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "049118fd-f5d6-4f65-9749-8f71e013199a", "name": "l(r:p1rdm20204-p1rlv19699)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd00c91a-01a8-4aad-b740-b06a654d631b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48654a82-ac11-4542-94ec-8f731138e1a8"}}}], "length": {"value": 0.0338608, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2c76a5dc-ab24-4233-b561-76095bf798b1", "name": "l(r:p1rdm20204-p1rdt9076lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdd64386-e256-47f8-8cef-1c933f993a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd00c91a-01a8-4aad-b740-b06a654d631b"}}}], "length": {"value": 0.0174413, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "eb46a639-7f1d-4e52-9a81-3b86dadfb400", "name": "l(r:p1rdm20205-p1rlv19686)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce8f50bb-90fb-49b8-8a16-1bbbb6a0c82c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47f5777d-2c8d-48c2-bf28-386f3f3dbac4"}}}], "length": {"value": 0.0229841, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "172f2ac8-d408-43a5-8f2f-85b7eb96c199", "name": "l(r:p1rdm20205-p1rdt9076lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdd64386-e256-47f8-8cef-1c933f993a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce8f50bb-90fb-49b8-8a16-1bbbb6a0c82c"}}}], "length": {"value": 0.017440300000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "642532af-cf6d-4892-bfa9-52b019bfbf8a", "name": "l(r:p1rdt9077lv-p1rlv19669)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b83eaaa-a092-42ca-a746-db4d9658d62b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96d3079a-02f1-4c89-ad75-fd0a438c9cf4"}}}], "length": {"value": 0.0293066, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b1bf45c3-70c8-4201-8c1a-d7d811dc7e70", "name": "l(r:p1rdt9077lv-p1rlv19675)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b83eaaa-a092-42ca-a746-db4d9658d62b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0031ab1b-d82d-40a5-b41e-bc6f6cb53069"}}}], "length": {"value": 0.00129939, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "a2668d78-c842-45e2-aeba-92c501e738bf", "name": "l(r:p1rdt9077lv-p1rlv19695)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b83eaaa-a092-42ca-a746-db4d9658d62b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35fe21a1-f817-426e-9e42-f1f33876dd7d"}}}], "length": {"value": 0.0295629, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7c77322f-3c54-4db1-b408-c1bcda2a0af3", "name": "l(r:p1rdt9084lv-p1rlv19681)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f0e4f59-8a46-4abf-9f06-e0383a59a45d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83afc678-d577-4ef1-afa2-8e3f915a158b"}}}], "length": {"value": 0.0407307, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ef70211b-06c5-4723-acbc-8f9aa7fe7d51", "name": "l(r:p1rdt9085lv-p1rlv19682)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "565bbfb1-a28f-4db2-be48-cbd58972025a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "811acd48-b61c-4a42-b76e-f995961c450e"}}}], "length": {"value": 0.0479288, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3052d3d1-b680-42ca-9619-45b322a57260", "name": "l(r:p1rdm20223-p1rlv19701)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec27727b-2bb8-4df2-9ddf-46282728c2c0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b5d936f-b3e0-408e-aabd-d3ebb7b869b0"}}}], "length": {"value": 0.05942600000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8693b634-c1ba-4076-b23e-61ae440e0c6b", "name": "l(r:p1rdm20223-p1rdt9085lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "565bbfb1-a28f-4db2-be48-cbd58972025a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec27727b-2bb8-4df2-9ddf-46282728c2c0"}}}], "length": {"value": 0.0186112, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4af17e9c-30e9-42ab-a616-44bee74bb9ea", "name": "l(r:p1rdt9089lv-p1rlv19689)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8108ac8-2807-4a40-85c2-db21efaadadb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "578b5df8-1dd8-41d9-b6dc-db75db5b115e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "a1434937-97ae-4da2-89f7-ebd1a788eb6a", "name": "l(r:p1rdt9090lv-p1rlv19690)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fc84159-09b1-4ca9-9a7a-a4fecab19f83"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2709a70-1a7d-454c-90fd-377e416a0071"}}}], "length": {"value": 0.0658315, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "67edc557-f853-458b-902b-2b073085da46", "name": "l(r:p1rdt9091lv-p1rlv19692)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e93ea18-150d-4d80-bac7-f3e1b87c5b4e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b10b272a-2efb-4e19-9921-d4081fb45778"}}}], "length": {"value": 0.0495767, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "86030b36-5fb5-416e-9704-398ab3aab79f", "name": "l(r:p1rdt9093lv-p1rlv19702)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f0726b7-3050-4c78-9c06-b9fd0c863ff3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37f72c85-61f7-4a42-94b0-6a627195458c"}}}], "length": {"value": 0.0423003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "41164760-4968-427a-ab0d-54100e9f5dc4", "name": "l(r:p1rdt9264lv-p1rlv20064)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c01a9b2-b002-4279-905e-950452f64f32"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aaea76fa-797e-46c5-a70f-a973977db841"}}}], "length": {"value": 0.0166628, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5e7381fe-5c31-423e-aa3a-7d6619d0c6d3", "name": "l(r:p1rdt9264lv-p1rlv20065)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c01a9b2-b002-4279-905e-950452f64f32"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea48ffa1-bdb3-4c15-96c9-ff7d7f34824f"}}}], "length": {"value": 0.0166628, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b84af902-253c-4e92-9494-157b730e98d1", "name": "l(r:p1rdt9265lv-p1rlv20066)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "77d62813-61d3-4afd-9f21-869e2ea23e17"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f450eeb4-3d87-4ae5-a6d6-958d7efd2712"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "2f422366-4e22-4f2c-8d50-1c6ba8a3374c", "name": "l(r:p1rdt9266lv-p1rlv20067)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78278589-be2d-4d99-9c03-92c221348917"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66a710fb-26c7-4465-b7ea-43ec107008dc"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "4f7d87f3-0ea4-4d93-b95a-cbe87c41dbc3", "name": "l(r:p1rdt9298lv-p1rlv20130)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "208f222c-45db-445f-ba0b-a4a195ca68a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ffc82be6-f3f8-4a68-b6e6-da60b137329c"}}}], "length": {"value": 0.0378956, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "bfcb695e-ecef-4564-813d-f2cb6bad6682", "name": "l(r:p1rdt9302lv-p1rlv20138)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180fad26-0e7d-4e2c-ba17-c8e3315ca278"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d635a151-2d13-47e9-8043-a214415a5b5e"}}}], "length": {"value": 0.057895600000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "39176fb1-de94-4c16-b64e-596ad25ee5f4", "name": "l(r:p1rdt9310lv-p1rlv20146)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4940a0e-dcc2-45fb-baa9-aadc84f8e882"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d615e93-a289-41ec-bda0-3b72bf15677e"}}}], "length": {"value": 0.052341200000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "71d34c49-4330-4c50-990a-3197e3ca5532", "name": "l(r:p1rdt9311lv-p1rlv20147)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9e0aa7d-9097-4370-8f5e-52a5885da85c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16b2add7-6a6d-4359-ad6f-f60edf435a4c"}}}], "length": {"value": 0.0259737, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8f3ee985-bbf9-4676-98e9-06a7c1d0a3d7", "name": "l(r:p1rdt9311lv-p1rlv20163)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9e0aa7d-9097-4370-8f5e-52a5885da85c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e938635b-e0d2-4e1b-a312-5a8f51e1dd7a"}}}], "length": {"value": 0.0357477, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ef39c360-8161-46c8-91bb-76651bc2d55f", "name": "l(r:p1rdt9312lv-p1rlv20148)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a21f5ca-51ef-4f81-8229-163182f011cf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4a0c2f2-f75e-4c9c-b3f7-d8d9ada9cb82"}}}], "length": {"value": 0.0268922, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3e7fdcaf-686b-496f-b34f-388785ad42a5", "name": "l(r:p1rdt9312lv-p1rlv20160)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a21f5ca-51ef-4f81-8229-163182f011cf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27dfea92-734e-49d3-b245-dc933df66889"}}}], "length": {"value": 0.0268922, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bc01fb01-4d37-4631-af7f-19d7e8269bbb", "name": "l(r:p1rdt9314lv-p1rlv20473)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3df13d91-365e-411b-917d-b28df5989280"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3eb214b9-827f-4995-a862-907be02b029d"}}}], "length": {"value": 0.0624435, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f48d1d5e-4709-4de9-b25d-ef596616a9fe", "name": "l(r:p1rdm20686-p1rlv20151)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5930295-0e44-4498-ae22-7647b72c1fa1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "956f4975-7383-4e0b-9114-d333a6ec4005"}}}], "length": {"value": 0.0773067, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c8ae9e69-9a3a-410a-9fd2-5ad1838b01c7", "name": "l(r:p1rdm20686-p1rlv20456)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5930295-0e44-4498-ae22-7647b72c1fa1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7a43aa6-2be8-4320-8089-57d388633c6b"}}}], "length": {"value": 0.0422263, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "97870ca0-fce4-48b0-85c2-87b76b884161", "name": "l(r:p1rdm20686-p1rdt9314lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3df13d91-365e-411b-917d-b28df5989280"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5930295-0e44-4498-ae22-7647b72c1fa1"}}}], "length": {"value": 0.0198942, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3435161e-0808-453b-ade5-697634ed4656", "name": "l(r:p1rdt9316lv-p1rlv20153)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c97a99f-545b-49cd-b1fe-4fd9e04bf37f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef20846d-d685-4c65-8dfb-bc23317501c5"}}}], "length": {"value": 0.021752800000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "633b6dd6-6a15-47ed-9d97-aebf2d9b5b6d", "name": "l(r:p1rdt9333lv-p1rlv20182)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a68a1c01-a04c-4af6-b1c8-02ddd1d67e0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20f93381-3834-4265-b1ec-5767d171ce0a"}}}], "length": {"value": 0.0263788, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b3b2c026-7b70-40e5-8478-180fd8809d5e", "name": "l(r:p1rdt9377lv-p1rlv20277)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e98299cb-8bad-49ea-8627-f3cfe01b9e23"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb7a8747-a076-469c-a150-35f6763157ec"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "087026c8-269c-4769-9c6f-af9a90b11306", "name": "l(r:p1rdt9381lv-p1rlv20281)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e37f182-5a60-470d-8f5b-ba145cc27973"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f23405b-432f-45ff-a7b1-0b7147cddfc8"}}}], "length": {"value": 0.0253793, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "59b8b45a-c9f3-49e3-8323-0d7dd87f9cb1", "name": "l(r:p1rdt9381lv-p1rlv20309)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e37f182-5a60-470d-8f5b-ba145cc27973"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e5718ad-0b70-4ea4-b2f2-31f0ea5c5d5b"}}}], "length": {"value": 0.0253793, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "26c34058-4892-4440-845b-5d3851809b0c", "name": "l(r:p1rdt9384lv-p1rlv20284)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abd09ea6-221c-47d9-beec-1062e0dd4aa7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25837ab0-0fb8-4346-94ad-561ff9ff7f0c"}}}], "length": {"value": 0.00420309, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9c16c054-b1ff-4e91-9010-39b32b8e0c3c", "name": "l(r:p1rdt9396lv-p1rlv20300)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc7e0a25-d6d6-4b07-b3dc-4fe5646915e2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da62d78e-e221-423a-8da0-8d36ce1f7508"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "d348f254-0831-467d-a2cf-24cff48b1fdc", "name": "l(r:p1rdt9413lv-p1rlv20333)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8180ee90-a46e-4d85-9742-d47b24f5e169"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c23afdc0-ab93-4d43-8eec-613eab21cd74"}}}], "length": {"value": 0.055563600000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d39e9443-e092-4bb9-890c-ec952b4704b1", "name": "l(r:p1rdt9413lv-p1rlv20358)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8180ee90-a46e-4d85-9742-d47b24f5e169"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b5d2dfa-895b-4afc-a7fe-449960adba41"}}}], "length": {"value": 0.055563600000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "5bf01fa7-0a38-4b2d-b944-93837af9be6a", "name": "l(r:p1rdt9463lv-p1rlv20432)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a015abb-ec63-4b31-9314-283b8499646e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4b5327a-85a3-496c-859c-f887a38513cd"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "e58c5ea4-bad0-4ebb-8dbd-9ba73b522dc9", "name": "l(r:p1rdt9468lv-p1rlv20451)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4dbe1628-cd17-4f37-af2b-dd752c290fa4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c37708d8-1e83-4e76-ac7f-0d29ba6b7c4e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "d36d6ce0-a328-49e6-8589-761a2846b82e", "name": "l(r:p1rdt9469lv-p1rlv20453)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09613257-d4cb-4c50-b35a-8aefc637c0c9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4e21b79-d2be-4a53-be46-32331e61f89c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "607be846-24c7-4d25-9222-e26430fd02e8", "name": "l(r:p1rdt9470lv-p1rlv20459)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1ab8727-2758-4513-8a7d-e02381faf1e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dfcfdbf-0051-4eef-bea6-97446cee21e4"}}}], "length": {"value": 0.0117286, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "03097dee-3563-430d-b479-e6da3aad6765", "name": "l(r:p1rdt9470lv-p1rlv20499)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1ab8727-2758-4513-8a7d-e02381faf1e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af153ed-ed39-4433-ac12-19dfdb7b6bef"}}}], "length": {"value": 0.0117286, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "abbb58b1-e018-43c7-8d8a-c43034cd923f", "name": "l(r:p1rdt9473lv-p1rlv20465)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c14c3211-a0d5-464f-820c-cab04764d907"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4759390d-43ec-45c9-9cca-320020dc1150"}}}], "length": {"value": 0.0334443, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4d466a6c-7eae-4477-a58b-84b46559fe6e", "name": "l(r:p1rdt9479lv-p1rlv20502)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6a8f268-6a5a-4b23-bd91-53c6b031442a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cacd3e49-55aa-4f05-bd7d-ae8aba0af87f"}}}], "length": {"value": 0.0132405, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "35f3ce10-7ea2-43a6-92f7-0e66c65507eb", "name": "l(r:p1rdt16638lv-p1rlv38126)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac361065-6b3c-4ac6-96d5-9b474eb3b80f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa4eed95-33b7-4827-8744-52d14149b386"}}}], "length": {"value": 0.00896862, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "950103b1-9ec6-4ba5-b24d-ea8b8cb59b5b", "name": "l(r:p1rdt16725lv-p1rlv38269)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bae9a352-584d-4cf0-9ebd-eb280b684e78"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cbb9976-253c-4863-899f-9218c4496688"}}}], "length": {"value": 0.00555125, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cf1cfe51-e7f4-4574-8253-da4972b54c2b", "name": "l(r:p1rdt7983-p1rdt8012)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bfb33cd-0cf1-455d-81e7-3d0472fa1b41"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e261b565-1f57-4cdc-bdd6-e045ee55d290"}}}], "length": {"value": 0.319354, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3b48fbf7-1282-4f8c-a6a8-8ae9f3b90bbf", "name": "l(r:p1rdt8012-p1rdt8034)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f83d22a-fa1e-4a4e-aab9-a9dea8ee06e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bfb33cd-0cf1-455d-81e7-3d0472fa1b41"}}}], "length": {"value": 0.0383866, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6243de73-7829-4099-a0ab-20bbf6c6ecea", "name": "l(r:p1rdt7954-p1rdt8034)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21e15d54-eab8-4204-9ed6-407fd8684700"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f83d22a-fa1e-4a4e-aab9-a9dea8ee06e5"}}}], "length": {"value": 0.256854, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9953443a-e512-47b5-b2da-2f9e9ddca7fc", "name": "l(r:p1rdt7954-p1rdt7973)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "016e4575-cd41-4993-be9b-5e5236a139ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21e15d54-eab8-4204-9ed6-407fd8684700"}}}], "length": {"value": 0.0497607, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a53ed3ef-f09a-4551-b82a-b6207878ef9a", "name": "l(r:p1rdt5172-p1rdt7973)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ea481f8-b9c7-4067-9bfb-4f7cdc5dee15"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "016e4575-cd41-4993-be9b-5e5236a139ae"}}}], "length": {"value": 0.289407, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "2c820636-d095-4272-9f89-d921819ff2af", "name": "l(r:p1rdt5155-p1rdt5172)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16712e10-4c7f-428b-917b-135ab3c2d4b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "afc636ed-f90c-4c48-822b-e86890d36f3b"}}}], "length": {"value": 0.0981862, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "cef0b639-e95b-4129-9dda-79e15491f213", "name": "l(r:p1rdt5155-p1rdt5172)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "afc636ed-f90c-4c48-822b-e86890d36f3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ea481f8-b9c7-4067-9bfb-4f7cdc5dee15"}}}], "length": {"value": 0.03419850000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "42c7cdb3-0fc1-4744-a4cb-bdb92a0ec9f0", "name": "l(r:p1rdt5155-p1rdt5201)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c289632-ba52-4b65-b6da-ac76b1477246"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16712e10-4c7f-428b-917b-135ab3c2d4b3"}}}], "length": {"value": 0.163704, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0e56a149-003c-40f3-90b4-32c09c9a86eb", "name": "l(r:p1rdt5159-p1rdt5201)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c289632-ba52-4b65-b6da-ac76b1477246"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee606236-08d7-4258-96c9-e9104f15b467"}}}], "length": {"value": 0.247666, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c41ff1f4-216c-4b99-9559-edc06bc0b68c", "name": "l(r:p1rdt5159-p1rdt5201)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee606236-08d7-4258-96c9-e9104f15b467"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90fb2270-4759-4779-80c1-7f93d66e1c53"}}}], "length": {"value": 0.0252803, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3b106144-995a-42f6-9105-373bd1547600", "name": "l(r:p1rdt5180-p1rdt5201)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86d3f96e-ffe2-459f-a2f1-b63d7bf138b8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c289632-ba52-4b65-b6da-ac76b1477246"}}}], "length": {"value": 0.165958, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "64b0948b-beb3-4234-9522-002661698319", "name": "l(r:p1rdt5923-p1rdt8346)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fec8a81-a151-4d8f-adc7-6d6d87d7759f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14b429c3-41da-4123-b661-40cbdfaf33e0"}}}], "length": {"value": 0.457454, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9be8e2a3-ed3b-4de7-8f25-6382fec041a4", "name": "l(r:p1rdt5923-p1rdt7988)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48e4b67a-0a47-48f0-b787-0a639db89caa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fec8a81-a151-4d8f-adc7-6d6d87d7759f"}}}], "length": {"value": 0.342603, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "cfb719d9-877c-4453-87ef-d4b5173d026f", "name": "l(r:p1rdt5180-p1rdt7988)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "893d2436-cd6c-40ad-90af-64ba1ac23f6e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48e4b67a-0a47-48f0-b787-0a639db89caa"}}}], "length": {"value": 0.958025, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4d35cd22-a1ac-48df-ae3c-d5a13715712d", "name": "l(r:p1rdt8447-p1rdt8456)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0089e5ea-d706-4a74-812f-654ae73eabcf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13b8cfc1-d8eb-4f47-b024-c1daacf3771d"}}}], "length": {"value": 0.30374700000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b83c03fc-f796-48d3-ad3b-2a3a22f58722", "name": "l(r:p1rdt8414-p1rdt8456)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34054ef8-8942-4471-ac14-43c6a37e5a16"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0089e5ea-d706-4a74-812f-654ae73eabcf"}}}], "length": {"value": 0.05634, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9e912236-8d08-4c01-94bf-41467552e199", "name": "l(r:p1rdt6272-p1rdt6274)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a53624b-8538-4cce-b588-c774875af31b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ac93b23-1041-486e-a16e-861082c92f35"}}}], "length": {"value": 0.108002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1c2a2bab-c82d-4a38-b710-8c8dfebf7049", "name": "l(r:p1rdt6272-p1rdt6274)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ac93b23-1041-486e-a16e-861082c92f35"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "034bda10-d48e-449c-9255-247cbf718683"}}}], "length": {"value": 0.00825442, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "923cb400-a742-4e52-948c-6c7d6cb7de45", "name": "l(r:p1rdt6271-p1rdt6274)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a75c5e2-2277-42b4-87d4-6eadff5c06f1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a53624b-8538-4cce-b588-c774875af31b"}}}], "length": {"value": 0.307488, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0a09a81b-a804-4407-b341-726e2c473678", "name": "l(r:p1rdt6270-p1rdt6271)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28954596-f060-4fa8-9f13-dfaa633bb739"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "898611f5-c343-4cca-8e5e-60cf0bfd796b"}}}], "length": {"value": 0.188113, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1369a137-ea26-496f-a49e-07fe1c36db1c"}}}}, {"uuid": "fe825001-39f1-4eda-af62-9c33a676d4b2", "name": "l(r:p1rdt6270-p1rdt6271)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "898611f5-c343-4cca-8e5e-60cf0bfd796b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b81bd5c2-96bb-445e-9eb8-d72360fd8a94"}}}], "length": {"value": 0.0296898, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "adfdca16-9dd2-4e84-828b-3cce8ceeead1", "name": "l(r:p1rdt7564-p1rdt7579)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76f6a27f-0e4f-48b8-9dbd-31c6ffc4ec75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa33ca9e-e16d-4c49-8a70-c6c30cf7b038"}}}], "length": {"value": 0.243188, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e28fa3c8-8478-435b-b24b-b2050db2515d", "name": "l(r:p1rdt7579-p1rdt7588)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76f6a27f-0e4f-48b8-9dbd-31c6ffc4ec75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f2dabc2-0b52-490c-b13a-32c268f6bd33"}}}], "length": {"value": 0.243808, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6c30a9e9-21aa-474e-8386-513a617c20c9", "name": "l(r:p1rdt7554-p1rdt7579)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f6de990-0988-4126-86ca-d1fd72c555fe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76f6a27f-0e4f-48b8-9dbd-31c6ffc4ec75"}}}], "length": {"value": 0.573836, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "558e228e-253b-4a6e-b393-6b01faeae27a", "name": "l(r:p1rdt7554-p1rdt7570)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2bdb2b51-0526-4995-bb5e-a2bd495488d4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f6de990-0988-4126-86ca-d1fd72c555fe"}}}], "length": {"value": 0.0647236, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d49f4c2c-8d0f-47c4-ae4b-a90f17979c57", "name": "l(r:p1rdt7559-p1rdt8015)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f239ef4e-83f0-4a2c-ada3-8e30cef38472"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff343735-753a-48ca-92b1-ea778c9e0b5c"}}}], "length": {"value": 0.10196200000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c0c2911d-ed07-4990-9abb-bc36add87fd0", "name": "l(r:p1rdt7559-p1rdt8015)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff343735-753a-48ca-92b1-ea778c9e0b5c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc543f54-740b-4a7f-b1c5-eb3783a8ade0"}}}], "length": {"value": 0.286466, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b9996b9e-d092-40f7-9d2d-9e261c16d724", "name": "l(r:p1rdt7559-p1rdt7570)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09814176-7891-4fe1-addf-b47aa106c40d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1dbec6c9-5c87-4f56-bd92-4a30d39ad094"}}}], "length": {"value": 0.14637200000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e4a51fb5-8e76-46ef-b920-7b77c5a4d877", "name": "l(r:p1rdt7559-p1rdt7570)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1dbec6c9-5c87-4f56-bd92-4a30d39ad094"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f239ef4e-83f0-4a2c-ada3-8e30cef38472"}}}], "length": {"value": 0.0849739, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1e1ff4ea-e8cd-413e-9ecd-a6b8b712c351", "name": "l(r:p1rdt7552-p1rdt7986)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db899c48-a801-4f83-b59d-e587ba80019d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "93a5388e-ffd7-403e-b6cf-26b7e81feed1"}}}], "length": {"value": 0.384727, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3c9d4cb9-43a5-4fef-a47c-22f1e23a19f3", "name": "l(r:p1rdt7551-p1rdt7552)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f0f3112-1395-48bf-88c1-8dd4b171478d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db899c48-a801-4f83-b59d-e587ba80019d"}}}], "length": {"value": 0.306203, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "887efa1d-3a26-4b29-9ee7-cd4d24b4122f", "name": "l(r:p1rdt7550-p1rdt7561)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc6bd64f-1ad3-4bd9-b590-7d4b673a94b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dead8520-e2f5-499b-9316-77780f9b1dfe"}}}], "length": {"value": 0.102524, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b5dbbf64-d586-472c-be8d-ec4d30c9538a", "name": "l(r:p1rdt8434-p1rdt8450)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f28de397-0db4-486a-8ce6-9f65c68703b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "184f95d4-cde1-4bf1-8a74-ebc7097cb10e"}}}], "length": {"value": 0.130615, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "310b27c0-aeca-4713-8dd9-75634008b0ca", "name": "l(r:p1rdt8434-p1rdt8440)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bbfe31b1-38ce-4ae4-9143-bf08c81617e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f28de397-0db4-486a-8ce6-9f65c68703b3"}}}], "length": {"value": 0.151253, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9d08c952-2d6b-430a-8ac4-049ad384831f", "name": "l(r:p1rdt8436-p1rdt8440)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bbfe31b1-38ce-4ae4-9143-bf08c81617e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "516ca275-0d8e-4a9a-ab59-89cb66b95d93"}}}], "length": {"value": 0.149159, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5ee7bf52-8efb-40b6-af57-c62fd8cd3acf", "name": "l(r:p1rdt8436-p1rdt8440)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "516ca275-0d8e-4a9a-ab59-89cb66b95d93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fcc42825-2690-4965-a99b-e78285a9b84e"}}}], "length": {"value": 0.105337, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "da33cb2a-7eaa-4cfc-9c3d-2a5cb32b1ee0", "name": "l(r:p1rdt8440-p1rdt8444)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bbfe31b1-38ce-4ae4-9143-bf08c81617e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f6e9b43-ceca-4a80-9569-696375a6ff5b"}}}], "length": {"value": 0.189207, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "81cb4004-68fb-40b6-a4c6-ce803572effe", "name": "l(r:p1rdt8440-p1rdt8444)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f6e9b43-ceca-4a80-9569-696375a6ff5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "685fbdbf-47af-4cc2-97ce-354dd04ce915"}}}], "length": {"value": 0.10008, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bc9ceca4-f632-4fd8-a6f7-84e549a2d515", "name": "l(r:p1rdt7555-p1rdt8440)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0075333-98fe-4ee8-bb64-a18119b817c0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bbfe31b1-38ce-4ae4-9143-bf08c81617e8"}}}], "length": {"value": 0.34151, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5f52d5ae-c7f7-405d-8cba-6f26dbf641c4", "name": "l(r:p1rdt7555-p1rdt7561)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc6bd64f-1ad3-4bd9-b590-7d4b673a94b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0075333-98fe-4ee8-bb64-a18119b817c0"}}}], "length": {"value": 0.0383631, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a5a9d7da-14d3-472d-9fbc-553a994c3f7b", "name": "l(r:p1rdt7551-p1rdt7561)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f0f3112-1395-48bf-88c1-8dd4b171478d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e068b84-fbff-4546-b708-ca91ffe92b69"}}}], "length": {"value": 0.124844, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0464cff4-421c-4922-a2f6-94dcd83b1534", "name": "l(r:p1rdt7551-p1rdt7561)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e068b84-fbff-4546-b708-ca91ffe92b69"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc6bd64f-1ad3-4bd9-b590-7d4b673a94b5"}}}], "length": {"value": 0.253169, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6d4670f0-7b81-49d7-8d20-f17d1629268c", "name": "l(r:p1rdt7551-p1rdt7574)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1d8c14d0-8247-4a44-98c1-4534aa9037a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f0f3112-1395-48bf-88c1-8dd4b171478d"}}}], "length": {"value": 0.382752, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "02a59a99-c259-48f2-92be-9d6473e77f82", "name": "l(r:p1rdt7553-p1rdt7572)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddf629eb-ea60-4fce-b731-7ebb33665829"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4307e78-304a-4175-8e81-9cb23d99f394"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0148f62b-4c0b-4711-8743-6575577331b4", "name": "l(r:p1rdt7553-p1rdt7574)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f00dd033-8e7c-43af-bd16-1de2954e07be"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7744d8d9-73a8-4274-9c91-5542620942f5"}}}], "length": {"value": 0.0977575, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "36947727-1aa5-4bcc-be37-bdb16a5a0db9", "name": "l(r:p1rdt7553-p1rdt7574)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7744d8d9-73a8-4274-9c91-5542620942f5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddf629eb-ea60-4fce-b731-7ebb33665829"}}}], "length": {"value": 0.0575736, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "14cc1fc7-59d4-4962-adf6-f9a219e7b2be", "name": "l(r:p1rdt5179-p1rdt6273)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9722136-480b-44cb-8b0e-0b3165712688"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d22f1247-b756-4498-8cf8-fef7d1e859ff"}}}], "length": {"value": 0.33969400000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ba35946f-4710-4036-87d9-e90e0fe76bc3", "name": "l(r:p1rdt8408-p1rdt8458)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28af960e-6f27-483a-8029-0c5f1641f51d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "433162b1-2a9b-4187-ba28-ec57503d76f6"}}}], "length": {"value": 0.0888364, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "71ca0f35-18a0-4a56-a50e-ad4f4c9b6f17", "name": "l(r:p1rdt8408-p1rdt8439)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07f340ca-58c2-4331-8265-a39a45c87b75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3430524c-820d-4f17-ba1b-377aeef4bbcd"}}}], "length": {"value": 0.217599, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "21683217-7a15-47db-8cb9-e443f8569fee", "name": "l(r:p1rdt8408-p1rdt8439)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3430524c-820d-4f17-ba1b-377aeef4bbcd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28af960e-6f27-483a-8029-0c5f1641f51d"}}}], "length": {"value": 0.0862144, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3871706d-53bc-4f3c-887c-1b304b0b5bc9", "name": "l(r:p1rdt6278-p1rdt8439)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19d5304c-574f-4646-8095-d2dcbbea86e7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07f340ca-58c2-4331-8265-a39a45c87b75"}}}], "length": {"value": 0.21709300000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6e3a4316-b83a-4df8-a57c-681507b74e08", "name": "l(r:p1rdt8405-p1rdt8445)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8c69243-872f-4e25-9d03-82692bbf8779"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e3ecdca-4b27-4a9d-8599-637924e86602"}}}], "length": {"value": 0.173131, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "99bc096c-88d2-40dc-84bb-74b6f5ee26b3", "name": "l(r:p1rdt8405-p1rdt8445)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e3ecdca-4b27-4a9d-8599-637924e86602"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc0ee90f-1f9e-435e-bac4-86a4688c48fc"}}}], "length": {"value": 0.152596, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "98f7d539-1e7f-40ee-8dda-dcda64bf53e9", "name": "l(r:p1rdt6500-p1rdt6519)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf648a0d-3262-4150-892b-55c3b117050a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5789c3b2-eb91-4e4c-85e8-24f5893e1a2c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1369a137-ea26-496f-a49e-07fe1c36db1c"}}}}, {"uuid": "daedf677-1099-4aa3-b007-b47edc2916ce", "name": "l(r:p1rdt6505-p1rdt6508)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0824c21-244b-4d4e-85d6-238ac4908b5a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb1c1e50-902d-443d-8c9a-b728d2f6b6f1"}}}], "length": {"value": 0.10179900000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d8c829f8-5194-4cb1-81b5-c3a846ffa9d2", "name": "l(r:p1rdt6510-p1rdt6523)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66b7b2e9-7658-4de0-8197-3829c6179353"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "848c04de-e4d5-4520-9dce-0073776c2ae4"}}}], "length": {"value": 0.167854, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "946d1cc9-2f20-4a54-9480-38deb15660e0", "name": "l(r:p1rdt5730-p1rdt9479)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e07d8bc1-2f8a-4067-a2a7-b903dd042ce3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5897bb2-1f72-4aeb-9090-74e2411b5786"}}}], "length": {"value": 0.30509600000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b0df22f1-d622-429d-8f86-7353e33fde28", "name": "l(r:p1rdt5840-p1rdt9479)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7f9286b-4209-402a-a365-1d27da4efb75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35722d90-049e-4c67-9654-acce0572e6c2"}}}], "length": {"value": 0.269952, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "10ffe1dd-0ef5-4c2b-971d-7dd0c7f0540a", "name": "l(r:p1rdt9298-p1rdt9302)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61ba1001-8b9d-481c-b205-45c6e0beadc1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4a41fe9-62ce-45ba-abcd-086ba429baa0"}}}], "length": {"value": 0.0784931, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b6cf13dc-5432-46f6-8ce7-4dcd6142e06d", "name": "l(r:p1rdt9298-p1rdt9310)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3035d22c-c39f-4f07-9fe9-29888b16057d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61ba1001-8b9d-481c-b205-45c6e0beadc1"}}}], "length": {"value": 0.189404, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ddc2c0a9-cf9d-4540-b621-99c53b060d78", "name": "l(r:p1rdt9310-p1rdt9316)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "644c5887-31f1-436c-bbf6-dae5a70743a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3035d22c-c39f-4f07-9fe9-29888b16057d"}}}], "length": {"value": 0.277772, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4617ca55-9b70-443a-912a-2c0b71d2435e", "name": "l(r:p1rdt9312-p1rdt9316)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "644c5887-31f1-436c-bbf6-dae5a70743a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8721684-5439-482c-b8e5-be330d3cf745"}}}], "length": {"value": 0.433834, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c9872dd4-7084-47d2-9b48-0a683d1d5018", "name": "l(r:p1rdt9311-p1rdt9316)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7011f1dc-1e7d-4961-9a23-620b7f5737af"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "644c5887-31f1-436c-bbf6-dae5a70743a2"}}}], "length": {"value": 0.0277071, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e40bd2c2-6249-4777-9efb-9cafe9e9e47b", "name": "l(r:p1rdt6518-p1rdt9311)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95d939ff-e20d-42b3-bb88-f1975f9fa0aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7011f1dc-1e7d-4961-9a23-620b7f5737af"}}}], "length": {"value": 0.103982, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4149df31-d706-455a-9122-9362e3df9b22", "name": "l(r:p1rdt5729-p1rdt5731)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "77d2122b-cbb7-4844-bbb2-55e939431e50"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52f308f4-35db-49ec-a599-f8380489f952"}}}], "length": {"value": 0.353232, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7b3b465f-dd27-42e7-804a-f97d4617ee2f", "name": "l(r:p1rdt5729-p1rdt5731)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52f308f4-35db-49ec-a599-f8380489f952"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95cd61cf-f1cb-4af2-9d3b-e42978642003"}}}], "length": {"value": 0.0107406, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "709aa023-da9c-4e74-80c6-9ac1241821a6", "name": "l(r:p1rdt5728-p1rdt5729)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b55c58cf-153e-4aa3-b099-8a1db05a6ae5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "77d2122b-cbb7-4844-bbb2-55e939431e50"}}}], "length": {"value": 0.125902, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f75bfbb4-dd53-4f91-99e8-d7364ccf82f6", "name": "l(r:p1rdt5728-p1rdt6537)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66ef2ffb-e67d-47eb-ae59-194c538ab861"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b55c58cf-153e-4aa3-b099-8a1db05a6ae5"}}}], "length": {"value": 0.543863, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b25e1279-aaff-4785-8b93-94d78d7a2bed", "name": "l(r:p1rdt6502-p1rdt9468)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b5695dd-714e-4de1-a63a-f142ff0460e1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e6348d4-7fcb-4546-af84-8ece75b6332f"}}}], "length": {"value": 0.434441, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7d206cf2-ecd2-4567-8615-e996c54cd96c", "name": "l(r:p1rdt6501-p1rdt9468)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddfa01c0-4d12-4f96-ab50-0082ef9914a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e4fd2ed-daa1-4a22-936f-8d51ee928d99"}}}], "length": {"value": 0.099806, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bd9d8818-aa67-4354-b9a9-81d0a90330c9", "name": "l(r:p1rdt6509-p1rdt6514)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42f09ae1-037a-4565-9cd2-0187c45b7866"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0737f6ec-0d5d-4cff-b4b7-9910c7076984"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ca790b78-4e94-4ea4-8d32-da938c5aef92", "name": "l(r:p1rdt6498-p1rdt6516)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60b93cd6-c9fc-46ef-8b37-6b14d0773df6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5c5466f-b7e4-4844-967b-9e8b11c68b44"}}}], "length": {"value": 0.0377529, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "34f48699-c9c2-4f8d-8e66-5822d807e169", "name": "l(r:p1rdt7298-p1rdt7313)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1f6ad7d-f7ea-4b94-956c-ec4a3b2028d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b658bf21-450c-4e6b-9dec-c5023a05fd19"}}}], "length": {"value": 0.0390759, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5d3b1a39-3b9f-43d5-a263-b7e274732cb7", "name": "l(r:p1rdt7036-p1rdt7091)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28d17238-8db8-41da-960c-317183423576"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "770cf0ab-50f1-489b-b2ea-d23ba186d10b"}}}], "length": {"value": 0.10505000000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "85f2d27c-47d3-49d1-9a52-3f41ebb66c72", "name": "l(r:p1rdt7036-p1rdt7091)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "770cf0ab-50f1-489b-b2ea-d23ba186d10b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52068090-b613-46d7-a31f-ad3ca26382d5"}}}], "length": {"value": 0.042633, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "81dd9e15-fe70-4d77-bf53-8ac6b6c4d15b", "name": "l(r:p1rdt7620-p1rdt7627)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97be7ac3-a710-4de8-a666-276813582cd6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5bddd75e-1974-41ee-ab51-625c7485a573"}}}], "length": {"value": 0.0237579, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6bdc087e-f95c-4fbe-bfc6-4a0c6270342d", "name": "l(r:p1rdt7311-p1rdt7620)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3a4dfb4-e1b3-43b9-ae42-b0cec47ff4ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97be7ac3-a710-4de8-a666-276813582cd6"}}}], "length": {"value": 0.142725, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ee2d29a7-a257-4805-9145-9257ecfda11e", "name": "l(r:p1rdt7311-p1rdt9473)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3a4dfb4-e1b3-43b9-ae42-b0cec47ff4ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4d8bafa-711d-4fd7-8374-7eeaeb43edcd"}}}], "length": {"value": 0.0811399, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3efc6b05-eb72-4c79-b237-e882fc3d458c", "name": "l(r:p1rdt7306-p1rdt7311)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "607c7275-da9a-4620-b019-59a66e98c2e6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3a4dfb4-e1b3-43b9-ae42-b0cec47ff4ad"}}}], "length": {"value": 0.0813524, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1ddc01b0-2a75-4050-b3a0-41dcad8ecd63", "name": "l(r:p1rdt7306-p1rdt7626)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "607c7275-da9a-4620-b019-59a66e98c2e6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56d67e3e-46af-4e2c-86a8-191d97b0ce8a"}}}], "length": {"value": 0.166342, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ac22d4a7-8ef7-47a3-8567-dbafa8b1ce03", "name": "l(r:p1rdt7302-p1rdt7306)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a65c4d3-2fc6-48c8-b944-68c4229db3dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "607c7275-da9a-4620-b019-59a66e98c2e6"}}}], "length": {"value": 0.183526, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e036c895-092e-4d78-ae61-8e6f09fca24f", "name": "l(r:p1rdt7302-p1rdt7617)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01c9d31d-c3bb-4950-9bbd-00377c252ddc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a65c4d3-2fc6-48c8-b944-68c4229db3dd"}}}], "length": {"value": 0.047802300000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "70140404-3f92-4e1f-a77d-b86b6a9a60d5", "name": "l(r:p1rdt7617-p1rdt7625)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a11cf3d9-90bb-4de8-b637-6ec9128525ec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01c9d31d-c3bb-4950-9bbd-00377c252ddc"}}}], "length": {"value": 0.0218023, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1f189dee-08e4-4079-bab5-e8a21d66de1f", "name": "l(r:p1rdt7616-p1rdt7630)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "723e2b5c-414c-4f3d-ba23-d2df4bc63e75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7167a2e-9e83-441e-a15b-0256848c3f6d"}}}], "length": {"value": 0.140205, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "fa7dc0a1-b720-42aa-93aa-5e53edf78be1", "name": "l(r:p1rdt7621-p1rdt7630)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa48cf27-3b07-4460-ad9c-8d9862238645"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "723e2b5c-414c-4f3d-ba23-d2df4bc63e75"}}}], "length": {"value": 0.0539367, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c2ab22f8-e100-4ef0-89b3-a41bcc8ad74f", "name": "l(r:p1rdt7621-p1rdt7625)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53df7b6e-bd8c-43f2-860d-8869aec5d079"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa48cf27-3b07-4460-ad9c-8d9862238645"}}}], "length": {"value": 0.18848800000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "771f897b-1f10-40db-b3d7-4066cc1d7638", "name": "l(r:p1rdt7054-p1rdt7090)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08d3a02a-555d-4ad1-9b13-d413b7a16eef"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3cf406b-69e6-4aee-a6fc-272dad7693a4"}}}], "length": {"value": 0.0578677, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "31498136-0f28-4bd8-98f5-9acb29e9649c", "name": "l(r:p1rdt7069-p1rdt7090)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aae22557-7d34-401d-82c9-2d2710ff2915"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08d3a02a-555d-4ad1-9b13-d413b7a16eef"}}}], "length": {"value": 0.128791, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "cdee7d08-5c71-4bf8-a182-b3c06db81686", "name": "l(r:p1rdt7069-p1rdt7087)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f614382d-3883-4f6b-b1f6-c8e83d84ee22"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aae22557-7d34-401d-82c9-2d2710ff2915"}}}], "length": {"value": 0.09476340000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d3bca9dc-c799-419f-9d47-eeac6c2ed7df", "name": "l(r:p1rdt7075-p1rdt7087)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8cebb186-4d9e-4d2c-b0d9-100056d34942"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f614382d-3883-4f6b-b1f6-c8e83d84ee22"}}}], "length": {"value": 0.198314, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1ee5dd7f-8852-4cb7-a544-f046413b4410", "name": "l(r:p1rdt7075-p1rdt7080)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "662e2a1c-9a54-4ac3-b478-98e3a478349d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8cebb186-4d9e-4d2c-b0d9-100056d34942"}}}], "length": {"value": 0.127901, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "389f514c-fe23-4cce-aa69-67e8571eb690", "name": "l(r:p1rdt7080-p1rdt7619)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "161d6f3b-8bd9-4fa8-9442-c6ff008e8d3d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "662e2a1c-9a54-4ac3-b478-98e3a478349d"}}}], "length": {"value": 0.059386400000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4cf5b365-3f96-468a-aeb9-3dcdf312110b", "name": "l(r:p1rdt7615-p1rdt7619)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "161d6f3b-8bd9-4fa8-9442-c6ff008e8d3d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "105df8ff-ec38-4cd6-b557-c318b4023bd0"}}}], "length": {"value": 0.217966, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3231a082-6540-4f71-a015-260c8614cb63", "name": "l(r:p1rdt7619-p1rdt7631)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9e53141-a773-4127-9558-3887070a8f36"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "161d6f3b-8bd9-4fa8-9442-c6ff008e8d3d"}}}], "length": {"value": 0.0570511, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4cc17ad4-3478-4c0c-8565-3dcaeb133743", "name": "l(r:p1rdt7625-p1rdt7631)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "460f5de9-8d4f-468a-b67a-b3b05354a9ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9e53141-a773-4127-9558-3887070a8f36"}}}], "length": {"value": 0.204577, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f8db6b2e-8307-43f8-a986-8c951fc06e7c", "name": "l(r:p1rdt6515-p1rdt6535)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fec078c2-a5d8-4317-a8ac-bc25772f6358"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5a05d0e-8cf2-4ab8-bdfd-24b8cd12ad67"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1369a137-ea26-496f-a49e-07fe1c36db1c"}}}}, {"uuid": "fcee0ed8-6baf-4eef-b433-a2ba9085968a", "name": "l(r:p1rdt6515-p1rdt6536)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04c1e05a-9cbb-4e53-9412-1cffd3976bed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5aa6899b-19a2-41e6-b445-f9fe2536c8d9"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1369a137-ea26-496f-a49e-07fe1c36db1c"}}}}, {"uuid": "16950521-fdd9-46ba-b9eb-d9f5b812710e", "name": "l(r:p1rdt8901-p1rdt8902)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d21061fa-1011-44f7-8a20-26fcf0550f52"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f23ab51c-56f3-4421-b66e-7cdcf109787d"}}}], "length": {"value": 0.309301, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b24e98ec-fd06-44e5-becf-6da45152feab", "name": "l(r:p1rdt7301-p1rdt9377)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61972a50-ce24-4ec1-8535-402665b55a55"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84200441-4c26-4966-a4b7-6b91fb43f02e"}}}], "length": {"value": 0.355831, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "33c4c723-7618-4494-9cf7-a8a01746a442", "name": "l(r:p1rdt8902-p1rdt9377)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43c862de-b014-4b24-8b34-54dae6edcf5a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32e86968-974e-4bcc-b562-1d4209771cf0"}}}], "length": {"value": 0.172034, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "04c8a47f-0b2d-4b5d-af7e-6361e20360cb", "name": "l(r:p1rdt8490-p1rdt9463)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37c41a4b-e439-42a1-b9a7-0582c528f0e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "271ab023-4425-40d8-8080-2481c71309b5"}}}], "length": {"value": 0.21351000000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "83e505b0-a9d8-4e85-ba9c-50cf7624af58", "name": "l(r:p1rdt8490-p1rdt8492)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "307d9c6d-d5ee-4490-95d3-5a9b1d171e54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37c41a4b-e439-42a1-b9a7-0582c528f0e5"}}}], "length": {"value": 0.0991871, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e2567550-8f85-4d77-96b7-a3ef3a0089e0", "name": "l(r:p1rdt7599-p1rdt8492)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "605c34bc-3f7c-4eb7-8df0-fcd00d261921"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3833996b-287c-4a13-9e7c-6834047f3691"}}}], "length": {"value": 1.29606, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5a80d1ee-2c0b-4cff-80ee-f9a438a10bca", "name": "l(r:p1rdt7599-p1rdt8492)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3833996b-287c-4a13-9e7c-6834047f3691"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "307d9c6d-d5ee-4490-95d3-5a9b1d171e54"}}}], "length": {"value": 2.04702, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7d48cc0e-c882-49ae-be92-fe816aa16373", "name": "l(r:p1rdt6226-p1rdt9333)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f6d3fab-3b83-40c9-85c4-cfeddd0d317a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76f24b35-1b82-4760-9817-80c166073f37"}}}], "length": {"value": 0.0994771, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6f3ebb5c-96d5-480e-8403-d35921fdeaae", "name": "l(r:p1rdt6226-p1rdt9333)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76f24b35-1b82-4760-9817-80c166073f37"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d81fc6d7-3400-41d4-91d7-b350d7def98d"}}}], "length": {"value": 0.117787, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5b73908d-2f28-48e9-a7e7-aa024cdccfc5", "name": "l(r:p1rdt5650-p1rdt5662)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36c3c493-ff68-4bb8-a3f4-043c5f847bd3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8f1c67e-9e29-45a3-a2a3-c2f3493a6898"}}}], "length": {"value": 0.373528, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bf809203-3662-4e57-8041-984c2164057f", "name": "l(r:p1rdt5658-p1rdt5663)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81f0e00e-bc49-448a-8e69-0569ed6a8c1a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67d07fb-aec5-4120-8254-32bfcd91e378"}}}], "length": {"value": 0.167002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "83ab7e51-98a6-4e95-b5fa-6c9c2095e331", "name": "l(r:p1rdt5658-p1rdt5663)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67d07fb-aec5-4120-8254-32bfcd91e378"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7356d982-36fd-46cb-9300-8889502e8dc8"}}}], "length": {"value": 0.0344971, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d376dca1-f218-4215-bdc9-4841f949ab27", "name": "l(r:p1rdt7046-p1rdt7067)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b470fa62-70d4-4cc5-8f7e-b9cda37481e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9bb8596a-bcb2-4282-bf1b-9939a9af87d9"}}}], "length": {"value": 0.207649, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "394c4f8d-a10c-4cc7-8d1b-605bc435f8b5", "name": "l(r:p1rdt7038-p1rdt7067)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb3a9847-70d0-4004-95ef-63884c6c1cdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b470fa62-70d4-4cc5-8f7e-b9cda37481e0"}}}], "length": {"value": 0.160885, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5af024a4-176d-4d88-92aa-1cce7304ee2e", "name": "l(r:p1rdt7038-p1rdt7070)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac6e8ccf-75ec-42e0-a3cb-9ab86e2731a4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9cb2d8d-1991-463c-9e6b-88f5624f28c3"}}}], "length": {"value": 0.0923408, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "26068bfb-36ee-4ac3-959b-e22ca0508ad2", "name": "l(r:p1rdt7038-p1rdt7070)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9cb2d8d-1991-463c-9e6b-88f5624f28c3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb3a9847-70d0-4004-95ef-63884c6c1cdc"}}}], "length": {"value": 0.238971, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a443312f-ca47-446d-960f-3de76a23b1f2", "name": "l(r:p1rdt9381-p1rdt9396)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a597011-5e60-46fe-90d6-85728ff0ffa3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5791345-57dc-4f54-ab54-ea63e6a54ee0"}}}], "length": {"value": 0.139587, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bcb59ecd-71f2-4a91-9918-2f6cfe394c47", "name": "l(r:p1rdt7088-p1rdt9396)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac70c13b-5f4f-45f3-880a-b4b476ea552a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a597011-5e60-46fe-90d6-85728ff0ffa3"}}}], "length": {"value": 0.16851400000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f066d9af-3a31-4e4e-9df6-3876ea0e5186", "name": "l(r:p1rdt7088-p1rdt7089)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31cd4834-477f-4060-8efd-0504c8e8eaa9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac70c13b-5f4f-45f3-880a-b4b476ea552a"}}}], "length": {"value": 0.07985440000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "08efaac7-6d95-4425-a194-e9fd5edb3d32", "name": "l(r:p1rdt7061-p1rdt7089)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75947ffd-3765-443b-bef8-b6af746ef624"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "324f5d62-9feb-4fe4-bc1b-3dcf01898148"}}}], "length": {"value": 0.135079, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1a1b0973-d4c6-47d7-8d97-e21a08b578a2", "name": "l(r:p1rdt7061-p1rdt7089)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "324f5d62-9feb-4fe4-bc1b-3dcf01898148"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31cd4834-477f-4060-8efd-0504c8e8eaa9"}}}], "length": {"value": 0.18246, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "552b8434-b608-4927-a5b9-ea068ccdc34d", "name": "l(r:p1rdt7061-p1rdt7070)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac6e8ccf-75ec-42e0-a3cb-9ab86e2731a4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84578de8-d5de-41fe-b637-42425e97b7db"}}}], "length": {"value": 0.128507, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3459416c-f085-4e60-9593-ce3b3585f76c", "name": "l(r:p1rdt7061-p1rdt7070)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84578de8-d5de-41fe-b637-42425e97b7db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75947ffd-3765-443b-bef8-b6af746ef624"}}}], "length": {"value": 0.322501, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a1c26b2c-7b4a-4027-88a6-1cbb94147d65", "name": "l(r:p1rdt5658-p1rdt7070)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02407b52-58c3-403c-9b5b-38695f435476"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac6e8ccf-75ec-42e0-a3cb-9ab86e2731a4"}}}], "length": {"value": 0.61978, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4c909e74-bd70-48ae-b4b9-fa6c0f49c742", "name": "l(r:p1rdt5017-p1rdt5200)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0843e99-e917-473c-bec7-ee0c3ddec601"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "799ab435-c0a4-4515-8125-e8ca2fb7632d"}}}], "length": {"value": 0.234989, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3904e139-a874-4ec4-b65c-f1113096a4b4", "name": "l(r:p1rdt7576-p1rdt8422)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b28595b-dcbe-4d1b-92c4-94acf370bb1f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ce65512-7d5f-4514-b55c-1775e80dd94d"}}}], "length": {"value": 0.0564986, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "91556012-ddc5-4cf8-828a-a6303f5cb1bd", "name": "l(r:p1rdt7576-p1rdt8151)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a31fa2-4df8-418a-a215-d0d450ced9a3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df71ab4b-258c-4812-9537-6d425bacb468"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "96c8992e-ab08-485e-8757-96b0e71fedc8", "name": "l(r:p1rdt7576-p1rdt8151)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df71ab4b-258c-4812-9537-6d425bacb468"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c951cf67-3297-407f-805c-55d9c03fb519"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "75782f97-8d8e-4957-97f0-8e2dabe321d9", "name": "l(r:p1rdt7576-p1rdt8151)_s2", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c951cf67-3297-407f-805c-55d9c03fb519"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b28595b-dcbe-4d1b-92c4-94acf370bb1f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7c6ac7b6-d8d7-455b-817c-4553072e5c9a", "name": "l(r:p1rdt8149-p1rdt8155)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1613a53e-5194-4d26-b83b-475d9f02a32c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b706c56-20f1-49ed-9cbe-0ec1491b83e0"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "40a5a234-9d35-48aa-8436-976911dc216f", "name": "l(r:p1rdt5153-p1rdt8441)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b423745-cc70-4c3a-adb0-f648170b4ab1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dac2cb8c-428b-49c4-8368-35608c050390"}}}], "length": {"value": 0.190536, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "cf871f54-cd17-4e6e-b56a-680cb64f1680", "name": "l(r:p1rdt5153-p1rdt8441)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dac2cb8c-428b-49c4-8368-35608c050390"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dff898c1-a386-4219-9e8d-2d08b49f9098"}}}], "length": {"value": 0.26071, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b28e3e27-9c0e-4a4e-89c9-565fdc854f99", "name": "l(r:p1rdt5153-p1rdt8441)_s2", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dff898c1-a386-4219-9e8d-2d08b49f9098"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb8dae66-287a-4b8a-9cda-6ae02cb8f8a9"}}}], "length": {"value": 0.128532, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "21a471ec-3f91-4bac-9f9c-2f63f39e7608", "name": "l(r:p1rdt8150-p1rdt8441)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78081763-07d2-4989-b492-e1c5178c4097"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83b76782-be09-4733-a35c-6f3f26059a4d"}}}], "length": {"value": 0.16747, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "59606c40-3050-4e1f-84d7-b3adeab006eb", "name": "l(r:p1rdt8150-p1rdt8441)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83b76782-be09-4733-a35c-6f3f26059a4d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b423745-cc70-4c3a-adb0-f648170b4ab1"}}}], "length": {"value": 0.585344, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9390eaa1-85ed-427d-b557-87485f68297d", "name": "l(r:p1rdt8150-p1rdt8442)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78081763-07d2-4989-b492-e1c5178c4097"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2ef098d-d7e6-4530-a5cc-b6472ec9ffdc"}}}], "length": {"value": 0.219381, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ae6dfad9-4b8b-4567-beea-e08350b422f2", "name": "l(r:p1rdt8150-p1rdt8442)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2ef098d-d7e6-4530-a5cc-b6472ec9ffdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6700763-e6dc-4626-ac2b-22985f0043be"}}}], "length": {"value": 0.29839800000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9914a6ee-984e-4689-83bb-a541dd092fc7", "name": "l(r:p1rdt8150-p1rdt8155)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1613a53e-5194-4d26-b83b-475d9f02a32c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b7280d1f-5ff9-45ee-9949-ecc70509a2a1"}}}], "length": {"value": 0.0723619, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "deed0a14-e67a-4500-9626-be034c9a20fa", "name": "l(r:p1rdt8150-p1rdt8155)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b7280d1f-5ff9-45ee-9949-ecc70509a2a1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78081763-07d2-4989-b492-e1c5178c4097"}}}], "length": {"value": 0.0446835, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8f14f92d-f5a4-4941-a518-79a7131e3bdd", "name": "l(r:p1rdt8155-p1rdt8157)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1613a53e-5194-4d26-b83b-475d9f02a32c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a30e197-897f-4516-b4e5-f70081e6f8c7"}}}], "length": {"value": 0.11694, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c9ae81de-99a7-45de-8eae-0dc8d72eb86c", "name": "l(r:p1rdt8151-p1rdt8155)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0a6628e-afc1-4daf-8a29-7626ac2aa5dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1613a53e-5194-4d26-b83b-475d9f02a32c"}}}], "length": {"value": 0.09203890000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "17a9aea4-714b-4a9e-bc93-6d59c828ea03", "name": "l(r:p1rdt5481-p1rdt5483)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f903015c-95a7-4d6e-b2a5-e9705c050c6e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d29d8b74-a24d-4474-9752-c1ffa1aa7f7c"}}}], "length": {"value": 0.218893, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bc927f95-acf8-4e59-9de3-a63c5a83649d", "name": "l(r:p1rdt5480-p1rdt5483)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2568f11c-8a37-4a55-8bce-9f0d56ac386a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f903015c-95a7-4d6e-b2a5-e9705c050c6e"}}}], "length": {"value": 0.0194577, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "dcc2039e-e644-4d69-b245-4b2970b5781d", "name": "l(r:p1rdt5477-p1rdt5480)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7d7f462-1ab5-4fd8-baaa-7e576eead5c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2568f11c-8a37-4a55-8bce-9f0d56ac386a"}}}], "length": {"value": 0.05838600000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "16f55ad7-24d9-4ec0-8729-a3f0c865164a", "name": "l(r:p1rdt5477-p1rdt7201)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7d7f462-1ab5-4fd8-baaa-7e576eead5c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df1d5615-4a0b-4041-8940-f13de9f7036a"}}}], "length": {"value": 0.101327, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "cb4e31da-15dd-4846-95b9-04865a0bcc59", "name": "l(r:p1rdt5477-p1rdt7201)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df1d5615-4a0b-4041-8940-f13de9f7036a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f64ed4a2-6afb-447c-8c6b-15935e050a6d"}}}], "length": {"value": 0.0635197, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1e1f4f6c-9c9c-4c7c-afa2-84cde862974f", "name": "l(r:p1rdt5472-p1rdt5477)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a8c3f7f-b9be-4c5e-b6f0-8f2fc18935fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "595463a5-2019-4c94-b72d-c824c2aef347"}}}], "length": {"value": 0.182509, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "436ac0bd-b246-48ce-94e1-7b1b0df0c7c7", "name": "l(r:p1rdt5472-p1rdt5477)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "595463a5-2019-4c94-b72d-c824c2aef347"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7d7f462-1ab5-4fd8-baaa-7e576eead5c7"}}}], "length": {"value": 0.00190877, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c20d723c-25d6-4888-b6f4-97cc3e392f79", "name": "l(r:p1rdt5472-p1rdt5476)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d69527e6-70b6-43e2-8b9e-7c8570ad5ddf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a8c3f7f-b9be-4c5e-b6f0-8f2fc18935fa"}}}], "length": {"value": 0.464713, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ac8991d3-6d78-4983-999e-61a1df7121c2", "name": "l(r:p1rdt7704-p1rdt9266)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02ea9067-6a2a-48b6-b5f1-10992b9fbd77"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f633393e-4d67-4646-838b-14f25641b426"}}}], "length": {"value": 0.327122, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "63d17b30-daf0-4906-8098-2e394c28e221", "name": "l(r:p1rdt7704-p1rdt9266)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f633393e-4d67-4646-838b-14f25641b426"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fbb2bd0-d109-4248-85f3-266fe479677f"}}}], "length": {"value": 0.119759, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "91bc4b46-c695-480b-858f-4fb349c9f026", "name": "l(r:p1rdt7704-p1rdt7712)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4462b9c6-748f-48e9-9ff9-7f20a06cf456"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02ea9067-6a2a-48b6-b5f1-10992b9fbd77"}}}], "length": {"value": 0.290826, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "74871719-24e2-4446-a5c1-6607bc9b6bd2", "name": "l(r:p1rdt7712-p1rdt7718)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4462b9c6-748f-48e9-9ff9-7f20a06cf456"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "048e2bab-67f2-4975-81a1-bbc9f2f9cd88"}}}], "length": {"value": 0.315016, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8fb5ae90-d852-4217-8ad8-7e35ff1771ef", "name": "l(r:p1rdt7701-p1rdt7712)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "74968ebc-53c5-4fc6-8172-3ffa9dea7683"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4462b9c6-748f-48e9-9ff9-7f20a06cf456"}}}], "length": {"value": 0.0526994, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "764fe5e3-4f60-49ac-b40e-80e11eef2a63", "name": "l(r:p1rdt7699-p1rdt7701)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec849ee4-3d69-46a9-9a2a-242a3943e46c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "74968ebc-53c5-4fc6-8172-3ffa9dea7683"}}}], "length": {"value": 0.0894152, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "948e03e5-6f8e-4e2a-b745-53bc7ae9fb10", "name": "l(r:p1rdt5485-p1rdt7699)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cfb3a23-3a93-4d89-8b70-e4730ebbce1a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "890cd47a-994b-4dca-8d59-25164f04c927"}}}], "length": {"value": 0.126204, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "432a59ab-ea4f-45fb-b79f-173e74a857ab", "name": "l(r:p1rdt5485-p1rdt7699)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "890cd47a-994b-4dca-8d59-25164f04c927"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec849ee4-3d69-46a9-9a2a-242a3943e46c"}}}], "length": {"value": 0.179947, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e51e0264-f754-45e2-a1b3-933e30c3cd56", "name": "l(r:p1rdt5475-p1rdt5485)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b9e57e0-6dc8-4831-ac7d-36f8608b7a8d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cfb3a23-3a93-4d89-8b70-e4730ebbce1a"}}}], "length": {"value": 0.0575139, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ecfbc31a-21c6-47a5-a744-7345eb49ee1e", "name": "l(r:p1rdt5475-p1rdt5476)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae343ca3-3337-4528-b117-38a51e6d023f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b9e57e0-6dc8-4831-ac7d-36f8608b7a8d"}}}], "length": {"value": 0.453804, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0dfee531-83f3-4357-8062-4451c875f683", "name": "l(r:p1rdt5476-p1rdt5478)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c977e6c-43f0-4d7e-b19f-82f0de97dab2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a97491e-2c98-4584-9b74-5593f17faeda"}}}], "length": {"value": 0.3849, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "63f4017a-0e53-4030-9f03-15546872260d", "name": "l(r:p1rdt6848-p1rdt9264)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96399e51-1243-4e7f-ae3a-5e2c67123aae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b764d22-debb-4d88-8221-ff79307e609f"}}}], "length": {"value": 0.24693, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "62ef9b36-dcd1-4bc0-907a-675b87e52164", "name": "l(r:p1rdt6848-p1rdt9264)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b764d22-debb-4d88-8221-ff79307e609f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bdf3994-bb0c-44f4-b1ea-ab29e73bd39c"}}}], "length": {"value": 0.116892, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3b953a51-c8a1-4a38-8773-f8a7016dfcbf", "name": "l(r:p1rdt6847-p1rdt6848)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e92b102-eaee-41cc-a2fc-c6c4b3bfb58b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96399e51-1243-4e7f-ae3a-5e2c67123aae"}}}], "length": {"value": 0.92611, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "480f3768-51e4-48e1-a449-a533eb206658", "name": "l(r:p1rdt6847-p1rdt7624)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be9350ab-7ad2-4a89-a374-94bf69588d7f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e92b102-eaee-41cc-a2fc-c6c4b3bfb58b"}}}], "length": {"value": 0.622643, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "2792a58e-fa63-427d-950f-9719c7fa27ea", "name": "l(r:p1rdt6348-p1rdt6350)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d6c5b78-35c4-475a-8837-776dea236c95"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c935f1c0-e36c-407d-a2e8-4181c4b0733e"}}}], "length": {"value": 0.150337, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bdb40655-4f94-4583-af63-540676cc787b", "name": "l(r:p1rdt6345-p1rdt6348)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40280da5-767c-4610-b6a8-ff411e1c33e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d6c5b78-35c4-475a-8837-776dea236c95"}}}], "length": {"value": 0.368527, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "50411b97-2ca0-4fd4-a03d-cd1d5a15d841", "name": "l(r:p1rdt6345-p1rdt6356)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1bdfc1ac-98a4-43dd-bb2c-837d0a2c15f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40280da5-767c-4610-b6a8-ff411e1c33e8"}}}], "length": {"value": 0.463971, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9944e15d-1d1f-4de2-b2d7-73810d8a552e", "name": "l(r:p1rdt6353-p1rdt6356)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1bdfc1ac-98a4-43dd-bb2c-837d0a2c15f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e51e0d9-24b6-40ac-859a-51ea74c93e76"}}}], "length": {"value": 0.407215, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "73284547-7d9c-4518-b0b1-abc15099090f", "name": "l(r:p1rdt6354-p1rdt6356)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1bdfc1ac-98a4-43dd-bb2c-837d0a2c15f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2040b1a2-85bc-405a-9dab-138561b5e3ac"}}}], "length": {"value": 0.108189, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6396a12f-73d3-4220-acb6-ffb04d2fd93a", "name": "l(r:p1rdt6354-p1rdt6356)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2040b1a2-85bc-405a-9dab-138561b5e3ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a05e7c9-4bff-46fd-b356-8120b481b053"}}}], "length": {"value": 0.017765, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d633367e-1657-4af7-9dfa-e9d06c37122b", "name": "l(r:p1rdt6347-p1rdt6356)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7166849-6ecd-4270-bf52-d0579838336a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1bdfc1ac-98a4-43dd-bb2c-837d0a2c15f9"}}}], "length": {"value": 0.633788, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5911af5d-66da-477a-9570-565ddc5292fb", "name": "l(r:p1rdt7598-p1rdt7605)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e36f1f1-6993-46b0-bafa-9530fd1652ef"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f95e5fa5-a84c-42a4-b519-8d344e816ecd"}}}], "length": {"value": 0.10583000000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "dd01fae1-634b-400c-a135-5dd7242a7e81", "name": "l(r:p1rdt7589-p1rdt7605)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f9809eb-41e0-40a8-b43a-93556f767f68"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e36f1f1-6993-46b0-bafa-9530fd1652ef"}}}], "length": {"value": 0.43683900000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1441ec02-dff2-4e01-af50-3ee3779998cb", "name": "l(r:p1rdt7589-p1rdt7612)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f9809eb-41e0-40a8-b43a-93556f767f68"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3410d88a-3e9c-427e-a79e-5c602455ed1d"}}}], "length": {"value": 0.525437, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "58ab57ef-9ed9-40ab-a4a0-72c5c4f3b6f6", "name": "l(r:p1rdt6347-p1rdt7589)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7166849-6ecd-4270-bf52-d0579838336a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f9809eb-41e0-40a8-b43a-93556f767f68"}}}], "length": {"value": 0.816381, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d601e0c8-87fa-4c4d-91e4-db629622c5ab", "name": "l(r:p1rdt6347-p1rdt8470)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6163371c-55ef-4900-a3ef-2e4e8fc2894a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7166849-6ecd-4270-bf52-d0579838336a"}}}], "length": {"value": 1.6455, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f9d802d6-7774-4bcd-92c8-41fed7e7cdec", "name": "l(r:p1rdt5218-p1rdt5653)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "769c14db-ac3f-438d-9f7d-c7eb2d3074b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98f2c16a-cdbd-49a3-b60d-4be6e9158480"}}}], "length": {"value": 0.123439, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ebc30854-15d0-4059-a4e4-a3b1a8071a39", "name": "l(r:p1rdt5218-p1rdt5653)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98f2c16a-cdbd-49a3-b60d-4be6e9158480"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dda7f7c-3b21-46a0-88a3-2b7f028b7772"}}}], "length": {"value": 0.122523, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4714a056-deff-4fcb-be44-1619b12bc118", "name": "l(r:p1rdt5195-p1rdt5653)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58c6d858-d457-4fe6-a45b-b9b2b73cad8c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fbc486eb-4f08-4602-a101-1298d4a46b32"}}}], "length": {"value": 0.10076600000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "242b9fb2-b832-46a9-b745-db7185470528", "name": "l(r:p1rdt6995-p1rdt7015)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3741c9d4-d03a-4b2f-be57-52a8977351ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d4d11a9-8de3-4dbe-8974-6005ed40f363"}}}], "length": {"value": 0.232606, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "699b5de4-087d-4717-9489-fb69e110294a", "name": "l(r:p1rdt6995-p1rdt7015)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d4d11a9-8de3-4dbe-8974-6005ed40f363"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6278a0d-f5d3-4b11-aee9-3bb23f9954a8"}}}], "length": {"value": 0.0860291, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f53d6c08-324f-49c9-9c3e-83864f308dc5", "name": "l(r:p1rdt16638-p1rdt16725)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c0d417e-c787-4b0a-a39e-b19ef274b36b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2d0eb0b-bbb6-4b3e-bdc6-4c8a0e7d466f"}}}], "length": {"value": 0.163486, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "176d8831-9ba5-4d7b-865b-99ea7e6aa381", "name": "l(r:p1rdt16638-p1rdt6995)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3741c9d4-d03a-4b2f-be57-52a8977351ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddb8e50b-2619-4e74-aee6-84dc4e11389e"}}}], "length": {"value": 0.166099, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b817c266-305b-4ad6-afa6-cdbd5b7def69", "name": "l(r:p1rdt16638-p1rdt6995)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddb8e50b-2619-4e74-aee6-84dc4e11389e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c0d417e-c787-4b0a-a39e-b19ef274b36b"}}}], "length": {"value": 4.23424, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "045afc0b-2012-4ca8-a295-71783d57d765", "name": "l(r:p1rdt5195-p1rdt6995)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58c6d858-d457-4fe6-a45b-b9b2b73cad8c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9056795d-5c81-4fb9-96bc-51d63b32b187"}}}], "length": {"value": 0.168784, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6a994cb4-f5f1-4df2-8d5e-c05435989755", "name": "l(r:p1rdt5195-p1rdt6995)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9056795d-5c81-4fb9-96bc-51d63b32b187"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3741c9d4-d03a-4b2f-be57-52a8977351ad"}}}], "length": {"value": 0.659388, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5c99986b-343d-4b8d-beb5-8d646498648b", "name": "l(r:p1rdt5195-p1rdt5202)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "227d848c-cddc-4561-996b-f8f7a60a5a89"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43e1b69a-c6dd-447e-82d9-921998de9837"}}}], "length": {"value": 0.168993, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bce828da-59ac-4d79-a897-197182228522", "name": "l(r:p1rdt5195-p1rdt5202)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43e1b69a-c6dd-447e-82d9-921998de9837"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e2f2704-4dee-4c78-b199-256b907156f3"}}}], "length": {"value": 0.111644, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "459455e3-ceff-404b-b7ce-cf80495c6db9", "name": "l(r:p1rdt5195-p1rdt5202)_s2", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e2f2704-4dee-4c78-b199-256b907156f3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58c6d858-d457-4fe6-a45b-b9b2b73cad8c"}}}], "length": {"value": 0.284889, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "14d0c4b1-b98e-469a-a68c-82291e282126", "name": "l(r:p1rdt5202-p1rdt5206)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97e4f179-9d60-4183-8326-eb0ab98a53eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17fedb14-6008-43fd-b7e9-342a113f27a6"}}}], "length": {"value": 0.19259500000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5b4278e7-9191-458b-b6c3-fcf736f69eaa", "name": "l(r:p1rdt5202-p1rdt5206)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17fedb14-6008-43fd-b7e9-342a113f27a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ed081eb-6b56-43b8-9cf8-e7ffdd8222f2"}}}], "length": {"value": 0.0669161, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "45ad7777-5030-4f58-baee-e3f8ffdcaa71", "name": "l(r:p1rdt5202-p1rdt7268)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a21680f1-33a7-44e1-9293-98c6861ba2a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6e61d2f-f75e-4335-aec9-4722942be9f1"}}}], "length": {"value": 0.301796, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5edc97b2-39e7-4ad3-89c4-4701b2b65678", "name": "l(r:p1rdt5202-p1rdt7268)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6e61d2f-f75e-4335-aec9-4722942be9f1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97e4f179-9d60-4183-8326-eb0ab98a53eb"}}}], "length": {"value": 1.26696, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7dcb8149-48f5-40b6-8bf7-d2a9a285cc09", "name": "l(r:p1rdt6349-p1rdt6355)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "88cc1382-6b14-4500-8a21-662fce6a0c0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c1edcfa-e0e4-4493-a9bb-e6033185ce67"}}}], "length": {"value": 0.0974401, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e157dc9b-2c86-419e-b934-ef99e273990b", "name": "l(r:p1rdt6355-p1rdt7224)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eeab7dfa-540c-4275-b159-f6ac4d1350f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "88cc1382-6b14-4500-8a21-662fce6a0c0b"}}}], "length": {"value": 0.455366, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4cbbff52-c85f-4eb7-b673-68e04d17547b", "name": "l(r:p1rdt7224-p1rdt7618)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eeab7dfa-540c-4275-b159-f6ac4d1350f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0fef9b3-a4bd-421c-8a54-cbf6f44c460d"}}}], "length": {"value": 0.282912, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d47ed6f4-4d52-4f70-a3e9-8fc6abdfb2c8", "name": "l(r:p1rdt7224-p1rdt7268)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a21680f1-33a7-44e1-9293-98c6861ba2a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22978d10-c9dc-4c84-8025-5749c730daa6"}}}], "length": {"value": 0.593134, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "2804c4ab-653b-4383-9793-17d37549fd78", "name": "l(r:p1rdt7224-p1rdt7268)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22978d10-c9dc-4c84-8025-5749c730daa6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eeab7dfa-540c-4275-b159-f6ac4d1350f9"}}}], "length": {"value": 0.197971, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c8da4fda-f3b6-4e5e-80ad-e99478be3bf2", "name": "l(r:p1rdt7268-p1rdt8470)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6225b33-2abc-4f77-9d65-459794f56353"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a21680f1-33a7-44e1-9293-98c6861ba2a5"}}}], "length": {"value": 1.40851, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8da487d2-4b45-4418-bfbc-c0dea1344931", "name": "l(r:p1rdt7735-p1rdt7790)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97198258-8ba3-4950-8747-3241c6a4fcee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62078787-3ae2-47b3-8f67-8e89e110c8be"}}}], "length": {"value": 0.206801, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f413d80b-c84b-4b47-b903-13ba7aaeb14e", "name": "l(r:p1rdt7790-p1rdt9090)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15a7847f-aa96-4206-b4c6-422802f4e0a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97198258-8ba3-4950-8747-3241c6a4fcee"}}}], "length": {"value": 0.246196, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "280746d1-8633-4f46-b5b2-5c3366afa2a9", "name": "l(r:p1rdt8911-p1rdt9384)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26613f51-86bf-4ae1-86c0-f23e48cf606e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7bc7d623-3ca7-4c4e-b11c-f373e90d06b6"}}}], "length": {"value": 0.11493, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4ea02402-fbd7-4f93-a5b3-87c7cba41c90", "name": "l(r:p1rdt8911-p1rdt9384)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7bc7d623-3ca7-4c4e-b11c-f373e90d06b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6eb9c7a5-5ab1-4d9b-a59e-538b68ad0bb9"}}}], "length": {"value": 0.0369839, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "76520eb4-9022-455a-95e2-68615f432757", "name": "l(r:p1rdt8905-p1rdt8911)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "924fc042-6ddc-484b-b09f-c65b35817d25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26613f51-86bf-4ae1-86c0-f23e48cf606e"}}}], "length": {"value": 0.148702, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "fe8ce15c-6fbe-4020-8e5d-d64427fd1c55", "name": "l(r:p1rdt8904-p1rdt8916)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "adcc33f8-72a3-434c-a021-6c5973713a91"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5584edfb-c31e-4e1d-87d3-b8161a59b15b"}}}], "length": {"value": 0.119301, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f35e4490-62b3-46a0-bb93-7194613325c6", "name": "l(r:p1rdt8904-p1rdt8916)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5584edfb-c31e-4e1d-87d3-b8161a59b15b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2edd17c2-6dfb-4f86-8998-b90a99755e96"}}}], "length": {"value": 0.0388388, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0d648254-33db-4f6c-b1a3-a5eb565882e2", "name": "l(r:p1rdt8905-p1rdt8916)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "924fc042-6ddc-484b-b09f-c65b35817d25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "adcc33f8-72a3-434c-a021-6c5973713a91"}}}], "length": {"value": 0.1748, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1f0641a1-24a2-44f6-a540-19f1d775a311", "name": "l(r:p1rdt8905-p1rdt8915)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "361385c6-bb6d-4bbc-ab7d-4a5774e03d82"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "924fc042-6ddc-484b-b09f-c65b35817d25"}}}], "length": {"value": 0.0903932, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "02e7d66a-a59b-4e2b-a49f-babf0eed8b45", "name": "l(r:p1rdt6574-p1rdt8915)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25a9ec20-35b9-4262-a02d-cafa63e5ee42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9ef9958-5d9e-4907-91cd-4c5d099daaf1"}}}], "length": {"value": 0.200113, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "01105eeb-78ae-43ca-8fef-2d73d4dd9715", "name": "l(r:p1rdt6574-p1rdt8915)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9ef9958-5d9e-4907-91cd-4c5d099daaf1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "361385c6-bb6d-4bbc-ab7d-4a5774e03d82"}}}], "length": {"value": 0.502215, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8fd323f7-0f6a-46f6-992e-bf7620907a90", "name": "l(r:p1rdt6574-p1rdt6581)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "599c6ed9-5ff7-4c97-a469-adceecaaf902"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25a9ec20-35b9-4262-a02d-cafa63e5ee42"}}}], "length": {"value": 0.214792, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5c51619f-c22d-4bab-88b1-5e86c6461402", "name": "l(r:p1rdt6581-p1rdt9084)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6114624f-81c8-4d9c-8f9a-3ab73158596e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "599c6ed9-5ff7-4c97-a469-adceecaaf902"}}}], "length": {"value": 0.220787, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8f71b6b2-940e-460b-aca1-395123d090d7", "name": "l(r:p1rdt9076-p1rdt9093)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2ce5116-c4f0-4ac7-a34f-3ba44c99d04b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c29179f3-0b4e-449c-8562-a8fcb675be6c"}}}], "length": {"value": 0.0790457, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "10112fc8-0706-4ca6-a9dc-155f2b62b426", "name": "l(r:p1rdt9076-p1rdt9084)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12b4dc99-fe50-457c-90aa-48a2fb19ebf1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2ce5116-c4f0-4ac7-a34f-3ba44c99d04b"}}}], "length": {"value": 0.143642, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7a562dd7-062c-47c7-a967-a36881222871", "name": "l(r:p1rdt9085-p1rdt9091)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "563c6bb3-d8ed-4fce-ad66-3892426248df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7fcdf409-885c-4c95-834e-988842ed3f5c"}}}], "length": {"value": 0.037383000000000007, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "816469ff-5ef9-491d-a0e5-f0cd167e7249", "name": "l(r:p1rdt9090-p1rdt9091)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf719d10-8168-4d80-894e-1b1516f033e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "563c6bb3-d8ed-4fce-ad66-3892426248df"}}}], "length": {"value": 0.176401, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f21c5d48-35f7-48b8-b0e3-e303cb6e0d3a", "name": "l(r:p1rdt9469-p1rdt9470)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5f6a2ec-3ddd-4ba7-9c55-88b4d82e7735"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acf91e46-ba32-44c3-a829-14c80a693d7d"}}}], "length": {"value": 0.0968012, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4f55c8b3-52d9-48bd-80b9-4336d109293f", "name": "l(r:p1rdt5140-p1rdt5184)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "431b672b-cb45-4294-b1f9-1d63f4efc8db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ceb58d66-3cb3-416d-aedf-f4949432eb37"}}}], "length": {"value": 0.11451800000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "87ff4d03-1265-417f-8396-f2223bf91dc2", "name": "l(r:p1rdt5140-p1rdt5184)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ceb58d66-3cb3-416d-aedf-f4949432eb37"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b0fd055-d0ac-4678-a8e5-679e12741736"}}}], "length": {"value": 0.0332053, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "049715c6-15cd-4adc-bfcb-405451aa8567", "name": "l(r:p1rdt5154-p1rdt5184)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50332aed-ecfd-465a-977e-c24ed6462860"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "431b672b-cb45-4294-b1f9-1d63f4efc8db"}}}], "length": {"value": 0.120991, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "76f0c663-18fa-4b81-a500-c47e1e85102e", "name": "l(r:p1rdt5142-p1rdt5154)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d579047b-82f6-49bf-bd7b-28c818d44bb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50332aed-ecfd-465a-977e-c24ed6462860"}}}], "length": {"value": 0.334614, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "756d1a3b-80d5-45f2-b945-05ac9c864cc7", "name": "l(r:p1rdt5142-p1rdt5180)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d579047b-82f6-49bf-bd7b-28c818d44bb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6316fa2-dd57-46d4-89c0-f11dd675d686"}}}], "length": {"value": 0.304739, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "23f00fb1-3a44-456d-adfc-200b1c385382", "name": "l(r:p1rdt5142-p1rdt8414)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b48f78d-1092-4536-bfb3-029da6a70dff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50f71b3d-83ce-4526-8057-4a38042b7295"}}}], "length": {"value": 0.0685574, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "e62ca4d7-5c98-4352-9f1d-520696b1d502", "name": "l(r:p1rdt5142-p1rdt8414)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50f71b3d-83ce-4526-8057-4a38042b7295"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d579047b-82f6-49bf-bd7b-28c818d44bb3"}}}], "length": {"value": 0.517385, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "591186a8-ed4e-49a7-a103-b77dc41ee44c", "name": "l(r:p1rdt6409-p1rdt8414)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42929633-40d4-4e13-a0aa-a7682f328226"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8648275-54c9-48e3-82e0-33119313924d"}}}], "length": {"value": 0.184195, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "712a1997-2d23-4337-adc2-b4f3245b7797", "name": "l(r:p1rdt6409-p1rdt8414)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8648275-54c9-48e3-82e0-33119313924d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b48f78d-1092-4536-bfb3-029da6a70dff"}}}], "length": {"value": 0.718647, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "40a640c0-70ae-4ede-af89-011fe2f9c3d6", "name": "l(r:p1rdt6409-p1rdt9413)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f750e531-5ade-40a9-9bb0-042220ce9807"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42929633-40d4-4e13-a0aa-a7682f328226"}}}], "length": {"value": 1.30529, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "9557eec3-679c-4760-af42-931b0ecaf811", "name": "l(r:p1rdt7570-p1rdt7574)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9b94106-b7c5-4ce9-9c19-053487848c2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd487832-bc77-406f-a995-4b099fad7c64"}}}], "length": {"value": 0.145959, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "4d38ea75-cd04-43b1-8a35-82c9b0e08cfb", "name": "l(r:p1rdt6275-p1rdt7570)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08d4c459-5bc5-4cad-8e74-613c4a08cb35"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9b94106-b7c5-4ce9-9c19-053487848c2a"}}}], "length": {"value": 0.362236, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "2e63b32d-43ae-42f8-bfbc-1179dc97926a", "name": "l(r:p1rdt6270-p1rdt6275)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cf36152-b3af-49f7-b693-5d465db1f283"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08d4c459-5bc5-4cad-8e74-613c4a08cb35"}}}], "length": {"value": 0.224093, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "a4f133cd-d305-41fc-9adf-8e347daa1943", "name": "l(r:p1rdt6269-p1rdt6270)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5ef97a6-6c60-46eb-acce-6469b273658a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cf36152-b3af-49f7-b693-5d465db1f283"}}}], "length": {"value": 0.284296, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "03db94ff-d792-433b-a8ab-a92dd86752d7", "name": "l(r:p1rdt6269-p1rdt8405)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60829dab-c129-4017-961a-81435d8afa93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5ef97a6-6c60-46eb-acce-6469b273658a"}}}], "length": {"value": 0.466915, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "afade1f8-1732-423e-b3af-635852b088ba", "name": "l(r:p1rdt8405-p1rdt9413)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16ecb938-cd0c-4be5-a915-be0d84d351f2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60829dab-c129-4017-961a-81435d8afa93"}}}], "length": {"value": 1.34967, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "aabe9c80-a880-4171-a383-28382ce12704", "name": "l(r:p1rdt6518-p1rdt9314)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d25f8d60-8aa7-4975-96dc-eba7696fa8ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d39c608-5688-4e22-8ac4-96b896265274"}}}], "length": {"value": 0.0596908, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "c08967c9-6afc-4436-b958-5f3dec162e2a", "name": "l(r:p1rdt9314-p1rdt9479)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b006c3-79f8-4a27-b76a-d1b458ff2a21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d25f8d60-8aa7-4975-96dc-eba7696fa8ae"}}}], "length": {"value": 0.23881800000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d9a45f7b-94cd-476f-b492-6be6d2c3273f", "name": "l(r:p1rdt6539-p1rdt9479)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9707f264-8f82-4483-8337-6c89d709faf7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b006c3-79f8-4a27-b76a-d1b458ff2a21"}}}], "length": {"value": 0.04213, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "5b6a5df1-5751-419e-9043-c59af2cb8468", "name": "l(r:p1rdt6507-p1rdt6539)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0db3e719-4dba-4b45-af70-c35546c19eb4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9707f264-8f82-4483-8337-6c89d709faf7"}}}], "length": {"value": 0.0349385, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "26afa7b6-b653-49b5-bf12-aa3c4938736f", "name": "l(r:p1rdt6507-p1rdt6530)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40ec7437-80f0-49e8-806a-c696b1402713"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0db3e719-4dba-4b45-af70-c35546c19eb4"}}}], "length": {"value": 0.28028700000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "221d6d6b-ad9e-406a-bf03-4b61c0d4feff", "name": "l(r:p1rdt6517-p1rdt6530)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b56340a0-81f0-4028-9283-532f0d92a412"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40ec7437-80f0-49e8-806a-c696b1402713"}}}], "length": {"value": 0.110659, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f60c7b67-fc17-4837-8efd-81efa3b23616", "name": "l(r:p1rdt6517-p1rdt6523)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "608945f2-9b19-43bc-83d9-0fe8787b06b4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b56340a0-81f0-4028-9283-532f0d92a412"}}}], "length": {"value": 0.281764, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "2c421fa7-4dd6-491c-998e-efe7bdb6b9f8", "name": "l(r:p1rdt6520-p1rdt6523)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24028ccd-3fd3-4461-b83c-54266f91a385"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b540c710-395d-4a35-8dc3-59d37609df09"}}}], "length": {"value": 0.0397382, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "ed24a3ca-3bd7-4de6-a546-05dc166ef9c8", "name": "l(r:p1rdt6501-p1rdt6520)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99fa55d1-867c-4db0-8697-b532da10d6d4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24028ccd-3fd3-4461-b83c-54266f91a385"}}}], "length": {"value": 0.0288844, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "be507d1a-0e3c-4956-b874-c26265167d1f", "name": "l(r:p1rdt6499-p1rdt6501)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "89434ebc-1e79-4414-9925-1a14f8e72fd6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99fa55d1-867c-4db0-8697-b532da10d6d4"}}}], "length": {"value": 0.0288269, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "6a77ab95-cadc-4be1-a0fe-1c155f22727c", "name": "l(r:p1rdt6499-p1rdt6509)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67c889f-e940-4242-9c83-4b5ab673d8a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "89434ebc-1e79-4414-9925-1a14f8e72fd6"}}}], "length": {"value": 0.026420600000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "b4fb2c7c-087c-479f-bb54-c153ff040105", "name": "l(r:p1rdt6508-p1rdt6509)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e165d0d-3f13-4d87-9c4b-fdfa8829f1f3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67c889f-e940-4242-9c83-4b5ab673d8a8"}}}], "length": {"value": 0.0278115, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "aac50a47-c224-459e-8507-4369a4d11f3a", "name": "l(r:p1rdt6508-p1rdt6521)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "302d2adf-2199-47b2-9f3c-e428bb409b6f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e165d0d-3f13-4d87-9c4b-fdfa8829f1f3"}}}], "length": {"value": 0.0189224, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f8244459-83a4-4ad3-a604-ec873ed20732", "name": "l(r:p1rdt6512-p1rdt6521)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f7572ed-6443-4e6e-8fb8-0b060b9f17ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "302d2adf-2199-47b2-9f3c-e428bb409b6f"}}}], "length": {"value": 0.0189224, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d5d29e6c-2471-43f5-85e9-7d24f91a352f", "name": "l(r:p1rdt6512-p1rdt6524)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ef8c502-c06f-43e5-90e6-23bd0ebcf155"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f7572ed-6443-4e6e-8fb8-0b060b9f17ce"}}}], "length": {"value": 0.0367319, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "672c8944-7a16-40e8-bdda-3b03fca4fecb", "name": "l(r:p1rdt7091-p1rdt7625)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6372a592-5e2d-41c8-819b-f56bfbb58e19"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2324afa4-5274-4392-9a0e-be8dc2bebeba"}}}], "length": {"value": 0.08221500000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f5dbe138-bea6-41cd-b524-27b90637c6e1", "name": "l(r:p1rdt7091-p1rdt7625)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2324afa4-5274-4392-9a0e-be8dc2bebeba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3e6cbe9-d1d3-4c59-981f-dad980f0999b"}}}], "length": {"value": 0.022555100000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f8e4f44c-08eb-469a-80c1-4f48efd02207", "name": "l(r:p1rdt7091-p1rdt7314)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0cf1844f-a32e-40f2-bc96-05fad3bdd88d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6372a592-5e2d-41c8-819b-f56bfbb58e19"}}}], "length": {"value": 0.55397, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "257675fc-6733-4332-ac51-3675463a4f35", "name": "l(r:p1rdt7314-p1rdt7318)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e86bc267-1607-4aa3-916f-ed826b0adfdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0cf1844f-a32e-40f2-bc96-05fad3bdd88d"}}}], "length": {"value": 0.048033200000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "e1ad2ae6-ae2b-46ab-a690-ea8d77ccc596", "name": "l(r:p1rdt7307-p1rdt7318)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "231b5cf9-ec2c-47d1-aada-5454926561dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e86bc267-1607-4aa3-916f-ed826b0adfdc"}}}], "length": {"value": 0.608118, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "12afdbdb-d635-4f2e-935d-dd9e846d84de", "name": "l(r:p1rdt6531-p1rdt7307)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8431ef4c-78dd-4a39-b15a-95818cfe1d86"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "231b5cf9-ec2c-47d1-aada-5454926561dd"}}}], "length": {"value": 0.626542, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "b628bac6-cc49-4fd0-869c-1e62b4f793f3", "name": "l(r:p1rdt6527-p1rdt6531)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "483b2d65-b496-4c6f-b01d-66aa3d9d4334"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "385eabe4-8c8e-4354-96ec-931e6c25574d"}}}], "length": {"value": 0.0295001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "00137112-a43a-4501-803e-980b8f2c0003", "name": "l(r:p1rdt6516-p1rdt6527)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5bd908fd-8bb8-42c1-8d1b-27c4e2574450"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "483b2d65-b496-4c6f-b01d-66aa3d9d4334"}}}], "length": {"value": 0.010689800000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "94115f94-82fa-4272-8a62-027168f25e3c", "name": "l(r:p1rdt6516-p1rdt6524)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ef8c502-c06f-43e5-90e6-23bd0ebcf155"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6191a237-532b-44e2-86a8-d9ed56b914b5"}}}], "length": {"value": 0.186537, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "5191d34f-932a-42dc-a5d6-0c1c0862b244", "name": "l(r:p1rdt6516-p1rdt6524)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6191a237-532b-44e2-86a8-d9ed56b914b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5bd908fd-8bb8-42c1-8d1b-27c4e2574450"}}}], "length": {"value": 0.014510300000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "310cb070-188c-4ff2-b290-6e36abcf555d", "name": "l(r:p1rdt6500-p1rdt6524)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a3d9ed9-e2e4-4332-89a2-358441869830"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97b7ef3c-ef16-4c4d-8559-722c5c67749a"}}}], "length": {"value": 0.0745596, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "beccb173-6f7b-4721-b3fb-e81b2efdd09f", "name": "l(r:p1rdt6500-p1rdt6515)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "18b822d0-cbe4-48d7-a818-87e25412d241"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0043b26d-8a33-4e32-a963-c4638f943775"}}}], "length": {"value": 0.030964300000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "de841033-13d8-4afb-bc0f-c55d72e49c5f", "name": "l(r:p1rdt6515-p1rdt6528)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04c3a970-215a-4e16-a798-80496ffad438"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8dcd059f-292b-4f7a-96c1-a3dc185f1eec"}}}], "length": {"value": 0.00777706, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "b9b34d6f-9985-4065-9d2f-788d5fa538da", "name": "l(r:p1rdt6528-p1rdt8898)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "918984ec-3b5f-4174-9bca-771bb10e0f60"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0156ae64-03dc-4ec0-89c8-8b09a6fc9090"}}}], "length": {"value": 0.0437869, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "75f64198-30d0-4129-ae28-939b6b4de497", "name": "l(r:p1rdt6532-p1rdt8898)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b51e96e7-2d7f-42af-9115-c9b1cfb3131c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "af1707bf-0b2e-4f76-96e7-c01338300d45"}}}], "length": {"value": 0.019358300000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "f1c45b69-986f-4c1d-aeaa-730d016e991d", "name": "l(r:p1rdt6532-p1rdt8902)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4a0469e-1a4a-466d-b18d-f3017b6415ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f373554-9d8a-4a9c-b418-25e67fbb43a9"}}}], "length": {"value": 0.0333077, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "88bad2e7-4dc4-4e4e-8175-a2a884f68169", "name": "l(r:p1rdt6052-p1rdt8902)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68b101ef-d71a-44d2-b1c2-4fc5e9f62499"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "468b1ce8-18fa-423b-99ca-1f3784437721"}}}], "length": {"value": 0.238793, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "eb115d37-81ae-4650-84a2-ae2f15289db2", "name": "l(r:p1rdt6046-p1rdt6052)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99e2ec8b-60fc-4a79-9eed-0d617babcb1d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49c69b43-f43b-4576-bbfa-d06b1d27de95"}}}], "length": {"value": 0.00843437, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "31a466b8-12d6-4b44-9bbb-89a8c774f869", "name": "l(r:p1rdt6043-p1rdt6046)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be3d7f84-84e7-46fc-a9ce-b3e0cf74d1d3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a147dd91-5597-40ff-93f9-0522ad3c726c"}}}], "length": {"value": 0.00839446, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "70cd133d-d616-4b6b-9e07-48fb34f306c9", "name": "l(r:p1rdt6043-p1rdt6045)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f01bba4-b8e8-45ed-af3b-1ac5a287ad46"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48d6768a-45e6-48a5-b22d-d5d418cb6221"}}}], "length": {"value": 0.04888200000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "f868b3e3-cc69-41ce-bcc7-0f7f802d7449", "name": "l(r:p1rdt6045-p1rdt6047)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34a9d21e-bcf7-4266-9834-60a72878ddd4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0396342e-2dc8-4a01-9da9-513953f9b5fa"}}}], "length": {"value": 0.08483280000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d8f16031-320a-40d2-a4bd-5b0e851ebb6c", "name": "l(r:p1rdt6038-p1rdt6047)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8898950-d712-40dc-99b5-33882b96b225"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34a9d21e-bcf7-4266-9834-60a72878ddd4"}}}], "length": {"value": 0.326021, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "598670a4-8ad9-464f-86c2-e9d706cc1558", "name": "l(r:p1rdt6038-p1rdt7599)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a086b782-3a8d-44e9-9948-cb7f051219e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cfe89e9-a7a8-456d-966b-67429017f456"}}}], "length": {"value": 0.186303, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "7223b7c0-3936-4480-8848-42bffaf1bdd0", "name": "l(r:p1rdt6038-p1rdt7599)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cfe89e9-a7a8-456d-966b-67429017f456"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8898950-d712-40dc-99b5-33882b96b225"}}}], "length": {"value": 2.13472, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "4d3942b3-144d-4b5b-82b8-ec7da5fb43f7", "name": "l(r:p1rdt6221-p1rdt7599)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0809ec5e-d36f-4bea-91b3-962ad6c29606"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a086b782-3a8d-44e9-9948-cb7f051219e3"}}}], "length": {"value": 0.192328, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d39bfedb-aa0c-466a-a29d-3c01eaa13638", "name": "l(r:p1rdt6208-p1rdt6221)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdfc617f-fbfb-4e9a-862e-cd5a296748cb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1a5a109-eee6-46be-be53-3fbe4a406575"}}}], "length": {"value": 0.728973, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "938225b2-6c7d-477d-9191-27d235904197", "name": "l(r:p1rdt6208-p1rdt6221)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1a5a109-eee6-46be-be53-3fbe4a406575"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0809ec5e-d36f-4bea-91b3-962ad6c29606"}}}], "length": {"value": 0.0421438, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "e39ddd12-2c19-406b-9cee-39fbbb7419bc", "name": "l(r:p1rdt6208-p1rdt8805)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "89f0c671-9d27-4dec-bd37-dc6c56f07e5d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdfc617f-fbfb-4e9a-862e-cd5a296748cb"}}}], "length": {"value": 0.531617, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "275d987b-6998-408d-8232-9db51e45c450", "name": "l(r:p1rdt5656-p1rdt5662)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17e89212-bc51-4fc2-83d1-4c74a285be23"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6f2bb66-d966-4228-8a13-96c57e8fbfba"}}}], "length": {"value": 0.240242, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "9904f6ea-b491-47e9-85aa-4261c1779673", "name": "l(r:p1rdt5656-p1rdt5662)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6f2bb66-d966-4228-8a13-96c57e8fbfba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f417a58d-5a47-4310-bac6-e8bb95fffc19"}}}], "length": {"value": 0.0265639, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "4573256d-e96e-413f-ac6b-b2c223599e79", "name": "l(r:p1rdt5183-p1rdt5662)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23f0bb81-3c30-45a5-89ca-2011e3881ddb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a05b2959-a8dd-417b-b566-8f84384a3559"}}}], "length": {"value": 0.290891, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "269826f4-1e62-47ca-aa90-96572f804c44", "name": "l(r:p1rdt5183-p1rdt5662)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a05b2959-a8dd-417b-b566-8f84384a3559"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17e89212-bc51-4fc2-83d1-4c74a285be23"}}}], "length": {"value": 1.81146, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "3f70e4f0-d581-4f32-bd85-f3b84da4c8ca", "name": "l(r:p1rdt4980-p1rdt5183)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35487e15-57cb-4e19-bef7-49074e5eb9ee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23f0bb81-3c30-45a5-89ca-2011e3881ddb"}}}], "length": {"value": 0.269563, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d3c03d49-abd6-4de6-8181-afe2d64d9e2a", "name": "l(r:p1rdt4980-p1rdt5017)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c09f718-9379-4281-86f6-55c46e46aec6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ddb0629-4947-47ca-83f9-9b7c073db235"}}}], "length": {"value": 0.216088, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "1c2a6e83-cb95-42de-bb6b-7b0e1cd4ea71", "name": "l(r:p1rdt4964-p1rdt5017)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7f13598-e628-457c-9ba6-d9a0123e882c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf1c765f-ca54-48cf-806f-6a1b5719c4b0"}}}], "length": {"value": 0.261316, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "eac4420e-03e8-40b1-ad16-db8f5eca18fc", "name": "l(r:p1rdt4964-p1rdt5017)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf1c765f-ca54-48cf-806f-6a1b5719c4b0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c09f718-9379-4281-86f6-55c46e46aec6"}}}], "length": {"value": 0.0641008, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "3b99e76c-8a82-4ca1-a9a0-80ecff2a4603", "name": "l(r:p1rdt4964-p1rdt8154)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42ab6054-1866-49c5-b2ab-3cf27199c1c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb1e0d86-907d-4564-a90e-c1400917d3ca"}}}], "length": {"value": 0.341502, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "55ed643d-0afa-4989-b1fd-d0adb37d81c8", "name": "l(r:p1rdt4964-p1rdt8154)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb1e0d86-907d-4564-a90e-c1400917d3ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7f13598-e628-457c-9ba6-d9a0123e882c"}}}], "length": {"value": 0.865306, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "5492331e-5c0a-4016-8ba0-bdc8e5d4f098", "name": "l(r:p1rdt8151-p1rdt8153)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b44d5021-4fdb-4618-bcb2-237ecf2e10e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40962258-28d3-4406-9e9e-121f373cce25"}}}], "length": {"value": 0.18735, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "05f00c42-916f-4b90-9aa8-833526068343", "name": "l(r:p1rdt8151-p1rdt8153)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40962258-28d3-4406-9e9e-121f373cce25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c794942-d5ce-481f-9c6a-563a2180a4ba"}}}], "length": {"value": 0.010421300000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d252c5f0-0b34-4738-8838-259761123b3c", "name": "l(r:p1rdt8153-p1rdt8154)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42ab6054-1866-49c5-b2ab-3cf27199c1c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b44d5021-4fdb-4618-bcb2-237ecf2e10e4"}}}], "length": {"value": 0.112826, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f7417ff2-16a5-4e81-a26b-dc86e9be6115", "name": "l(r:p1rdt8154-p1rdt9333)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0da91bf8-b687-47df-a7dc-41e6166fd667"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aef77ef-aaaa-4a6e-90ef-87348baaf1a0"}}}], "length": {"value": 0.37829, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "398b071f-89c3-461e-a564-1de7f6d5c967", "name": "l(r:p1rdt8154-p1rdt9333)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aef77ef-aaaa-4a6e-90ef-87348baaf1a0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42ab6054-1866-49c5-b2ab-3cf27199c1c8"}}}], "length": {"value": 0.2985030000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "76623ce2-1798-436d-8d11-cfcdc4e48d8e", "name": "l(r:p1rdt8805-p1rdt9333)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3444af6b-f9d4-4229-b6b2-2114300c3f94"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0da91bf8-b687-47df-a7dc-41e6166fd667"}}}], "length": {"value": 0.4807600000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "b055443b-30b0-4f4b-bbe3-54ed03e935bc", "name": "l(r:p1rdt8802-p1rdt8805)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26ccaeff-3a34-4835-8906-1145148549c6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3444af6b-f9d4-4229-b6b2-2114300c3f94"}}}], "length": {"value": 0.287236, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "62bc44cf-8afa-47da-9b7f-18b3ec7b3fff", "name": "l(r:p1rdt8802-p1rdt9413)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "401576cc-4ad6-42cd-bf1c-4022da720711"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e527bf48-b574-43bd-9a5d-484654dc76fe"}}}], "length": {"value": 1.38145, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "19fd814e-e169-4dc3-a33e-fae841593afd", "name": "l(r:p1rdt8802-p1rdt9413)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e527bf48-b574-43bd-9a5d-484654dc76fe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26ccaeff-3a34-4835-8906-1145148549c6"}}}], "length": {"value": 0.181709, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "06dd8bda-4d2d-43a7-a006-b168f73e922c", "name": "l(r:p1rdt5126-p1rdt9413)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0dafde2-c08e-4624-9212-e0fea9e47c2c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f750e531-5ade-40a9-9bb0-042220ce9807"}}}], "length": {"value": 1.23272, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "243ed967-e94e-485e-8b9d-afcbd257a23f", "name": "l(r:p1rdt5126-p1rdt5342)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c8f9ea6-06fb-4fd0-8629-ceea4f32189f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0dafde2-c08e-4624-9212-e0fea9e47c2c"}}}], "length": {"value": 1.97105, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "1a44ac5c-bd61-4c05-add0-330d7b09af79", "name": "l(r:p1rdt5476-p1rdt7624)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e240270-762d-49f0-a4e4-29fcd6273ce5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b077dc9c-1c6f-4403-ae0c-954e7cc0c692"}}}], "length": {"value": 0.421903, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "cc2acfa4-f76c-49fb-9790-7a02064a106b", "name": "l(r:p1rdt7624-p1rdt8159)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42b9c576-ddba-4be1-bc64-a37d8cbdfa84"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1ab9716-b9f3-44e5-b9f6-cd83d0904dd3"}}}], "length": {"value": 0.172459, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f0f84804-681f-45a5-b03b-c90ab2f2d6ff", "name": "l(r:p1rdt7624-p1rdt8159)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1ab9716-b9f3-44e5-b9f6-cd83d0904dd3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e240270-762d-49f0-a4e4-29fcd6273ce5"}}}], "length": {"value": 0.601263, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "542b2bb0-327d-4aab-a521-e1b0208513fc", "name": "l(r:p1rdt8159-p1rdt8161)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25946c74-15c2-412c-baed-8de5f7aecf98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42b9c576-ddba-4be1-bc64-a37d8cbdfa84"}}}], "length": {"value": 0.18407100000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "007f222e-ee77-4ddd-a2b9-453252e10c12", "name": "l(r:p1rdt7253-p1rdt8470)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f31b09da-e4cc-409e-9634-1907480039ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "442de065-9e2a-4ff8-9100-1298d3fe0f6f"}}}], "length": {"value": 1.51192, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f872437e-3f61-48ba-b719-7dec231c6092", "name": "l(r:p1rdt7248-p1rdt7253)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a006c5f-e960-4ae2-a37f-d23d7b873a22"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f31b09da-e4cc-409e-9634-1907480039ff"}}}], "length": {"value": 0.16946100000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "126d74f6-247e-4072-a5df-2c3d434063f3", "name": "l(r:p1rdt7220-p1rdt7248)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a2f1a631-48f7-4291-9adb-588a66620ebf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a006c5f-e960-4ae2-a37f-d23d7b873a22"}}}], "length": {"value": 0.306328, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "05aee401-6d4c-4709-8f97-3c50231daf5e", "name": "l(r:p1rdt7220-p1rdt8160)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38b72c12-2e2f-4d83-8f5a-9d8503dc29eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a2f1a631-48f7-4291-9adb-588a66620ebf"}}}], "length": {"value": 0.197573, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "95d74719-df14-429b-a976-0df68eb96622", "name": "l(r:p1rdt9075-p1rdt9084)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "907828f5-8e26-41c4-8fbc-a3744608181a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c10b6848-6c57-4243-8cb9-ec28d0a4c9dd"}}}], "length": {"value": 0.178898, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "3eafde29-da04-4c84-8fb6-7f4688eda991", "name": "l(r:p1rdt9075-p1rdt9084)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c10b6848-6c57-4243-8cb9-ec28d0a4c9dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4251587d-600f-40a0-9aec-229fb2e3f2df"}}}], "length": {"value": 0.27713400000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "fd3b2cfd-59b4-44c7-b0e7-303bae472d10", "name": "l(r:p1rdt9075-p1rdt9077)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b7f2f09-976a-45da-8186-229aeedeb689"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "907828f5-8e26-41c4-8fbc-a3744608181a"}}}], "length": {"value": 0.564064, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "347ee642-da70-4556-80d2-c3ac791c95eb", "name": "l(r:p1rdt9077-p1rdt9089)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b4ec275-bea8-45f2-94cb-5e24e82179d8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b7f2f09-976a-45da-8186-229aeedeb689"}}}], "length": {"value": 0.0696185, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f1cb1cc4-91cf-4ec1-a7a3-133827bae335", "name": "l(r:p1rdt9089-p1rdt9090)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52c72b52-1c6c-46f6-adbe-1054eb233c20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e4d2db3-67c5-4fef-996a-5774803c89b1"}}}], "length": {"value": 0.172405, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "fd0103af-8848-4f0a-8530-fac681f8ac46", "name": "l(r:p1rdt9089-p1rdt9090)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e4d2db3-67c5-4fef-996a-5774803c89b1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b4ec275-bea8-45f2-94cb-5e24e82179d8"}}}], "length": {"value": 0.0139334, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "df82aa08-b98c-4a21-89f9-d1b76cfe2af4", "name": "l(r:p1rdt9090-p1rdt9469)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3fd32c7-2866-4699-93a8-dd3a9997d349"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "708803a5-3daf-4892-96e3-b182e2d214ec"}}}], "length": {"value": 0.170175, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "fcb909f2-d354-474b-aee1-a6ca2eb94969", "name": "l(r:p1rdt9090-p1rdt9469)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "708803a5-3daf-4892-96e3-b182e2d214ec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52c72b52-1c6c-46f6-adbe-1054eb233c20"}}}], "length": {"value": 0.101162, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "2825eafe-8b85-450e-bed0-ab9a8e074f2d", "name": "l(r:p1rdt8160-p1rdt9469)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38b72c12-2e2f-4d83-8f5a-9d8503dc29eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3fd32c7-2866-4699-93a8-dd3a9997d349"}}}], "length": {"value": 0.245773, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "13deaf06-081a-4c2c-b09a-13b3d3c7335b", "name": "l(r:p1rdt8160-p1rdt8161)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8ecbd5b-6db5-44a0-b2a8-0233d4eb5b20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc9cbaf2-05bd-49aa-bd14-a363d4970d0f"}}}], "length": {"value": 0.191607, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "c5288543-a096-4660-bf4a-2929c4c54201", "name": "l(r:p1rdt8160-p1rdt8161)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc9cbaf2-05bd-49aa-bd14-a363d4970d0f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38b72c12-2e2f-4d83-8f5a-9d8503dc29eb"}}}], "length": {"value": 0.415051, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "b887aaee-21fc-4122-9966-afa362c2a743", "name": "l(r:p1rdt5236-p1rdt8161)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22db53ea-6d9a-4527-9b36-34a4bcd2c74f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67967bdd-155c-49fd-8d4c-29b40415a243"}}}], "length": {"value": 0.0839258, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f602002d-891a-4cda-82bc-55026a5de403", "name": "l(r:p1rdt5236-p1rdt8161)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67967bdd-155c-49fd-8d4c-29b40415a243"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25946c74-15c2-412c-baed-8de5f7aecf98"}}}], "length": {"value": 0.757497, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "10415944-6d9a-4497-bbb6-d304cebe9536", "name": "l(r:p1rdt5236-p1rdt5342)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9bbfae79-a578-4ff2-b622-3dddd9859ac8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22db53ea-6d9a-4527-9b36-34a4bcd2c74f"}}}], "length": {"value": 1.97703, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f8620c0f-f6b7-4b1c-abcf-c32e418abafc", "name": "l(r:p1rdt5342-p1rhs7_1247)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14208aa5-3197-4c90-adf9-3067dae9b5f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c8f9ea6-06fb-4fd0-8629-ceea4f32189f"}}}], "length": {"value": 0.373586, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "038d8c23-c731-48d4-9f20-56de4007395d", "name": "l(r:p1rdt5154lv-p1rlv10539)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9750085f-4afd-48ee-89f3-edbe9687b242"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08331744-08b7-455e-b2ca-284cae95fb06"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "4897e763-4729-42e4-a83c-2555a1a08472", "name": "l(r:p1rdt7632lv-p1rlv16271)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7235cf3a-dd26-47f7-884c-6335024a3064"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "606bf8f6-d745-4220-8cae-e01ffd22f669"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "323fd365-c57f-480b-9a0d-7f496d60a8db", "name": "l(r:p1rdt7632-p1rdt9265)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b336e76f-17f3-4f5d-ba84-f24c3a4e3eed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36e7cd28-6795-41d5-847d-92347871384f"}}}], "length": {"value": 0.178943, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "78cda3f2-1738-44fb-b107-a25d2930dde8", "name": "l(r:p1rdt5140-p1rdt9265)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b0fd055-d0ac-4678-a8e5-679e12741736"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60837f06-40cb-4f12-b36f-fe5e502c96d9"}}}], "length": {"value": 0.223266, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "455cb6d9-470c-4b2b-bfd7-589240e9226b", "name": "l(r:p1rdt5140-p1rdt9265)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60837f06-40cb-4f12-b36f-fe5e502c96d9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b336e76f-17f3-4f5d-ba84-f24c3a4e3eed"}}}], "length": {"value": 0.0122242, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "97bf6cd1-1211-4a45-8bf3-7091c7785df7", "name": "l(r:p1rdt6279lv-p1rlv13061)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6614f5e-517f-46cf-b049-09337d57228a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d46fd47-37f5-48a0-ba0d-d0746e6e6da3"}}}], "length": {"value": 0.0894278, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "a35032da-9a40-4dfe-ac94-e654ae966ae4", "name": "l(r:p1rdt6270-p1rdt6279)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb21415c-fc85-4197-82e5-545cb7be2ce9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1565cfb-f699-47db-9cbf-a76c32e3ea69"}}}], "length": {"value": 0.141369, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "f782b59f-9336-471b-a725-6924905057a8", "name": "l(r:p1rdt6270-p1rdt6279)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1565cfb-f699-47db-9cbf-a76c32e3ea69"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5c579309-9c05-4bae-ab97-2eca485e5ea7"}}}], "length": {"value": 0.0289817, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "e34d7eec-d2c0-4c8f-b361-a88dcd056e29", "name": "l(r:p1rdt6273lv-p1rlv13050)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07992f45-0c92-4a10-837d-4f58599d9b75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "051eba03-4728-4626-8add-5410b5326dc7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "f937594c-fb88-439e-99c9-fda1597eefef", "name": "l(r:p1rdt6268-p1rdt6273)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2f8b91d-339f-4151-90df-b0cad5c2f05a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d04f281-f394-432b-8b5c-cc1acb741369"}}}], "length": {"value": 0.0655674, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "6952320e-ff8d-460d-a4e6-eaf6036b287a", "name": "l(r:p1rdt6268-p1rdt6276)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b31c2adb-e4f4-4211-aac7-f317bf325d12"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce404489-b775-486b-9379-a30c801f6f94"}}}], "length": {"value": 0.246128, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "10f741eb-d2e6-4be0-af4e-b361024769a0", "name": "l(r:p1rdt6268-p1rdt6276)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce404489-b775-486b-9379-a30c801f6f94"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68d2e030-852f-44f6-9e02-d5587a1fc6a0"}}}], "length": {"value": 0.05302, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "84492e74-9344-46cb-a390-f1e004543e53", "name": "l(r:p1rdt6276-p1rdt6278)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51eefb94-724e-4dfe-9823-0f6cf8f56101"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "315af04d-a032-43a8-a2da-b9e68fd21f39"}}}], "length": {"value": 0.154279, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "62a19b90-201e-4b90-8182-f185a38720e2", "name": "l(r:p1rdt6277-p1rdt6278)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1dd4f893-7921-41c3-9e9e-d33e3680a999"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51eefb94-724e-4dfe-9823-0f6cf8f56101"}}}], "length": {"value": 0.0625926, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "b95ba635-9420-4efc-b1f4-f18ab2981eb2", "name": "l(r:p1rdt6269-p1rdt6277)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5ef97a6-6c60-46eb-acce-6469b273658a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "699595d6-8e08-41b1-8c3a-2aef170bb5f7"}}}], "length": {"value": 0.114982, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "6a531a0c-c604-445f-ad7e-c5819157e2fe", "name": "l(r:p1rdt6269-p1rdt6277)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "699595d6-8e08-41b1-8c3a-2aef170bb5f7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1dd4f893-7921-41c3-9e9e-d33e3680a999"}}}], "length": {"value": 0.0390023, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "fe16e73d-9f26-4912-b410-968f808d698e", "name": "l(r:p1rdt6045lv-p1rlv12555)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70bad714-71c1-4341-ac40-76312417dd03"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc71e486-4a44-466d-bc57-85591b269949"}}}], "length": {"value": 0.0236063, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "5d709edf-06ff-4ca8-9765-3865bab61031", "name": "l(r:p1rdt6052lv-p1rlv12567)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d830a1b-6971-4f4d-99bd-945e0785b5aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29476f95-f85b-4843-a847-3d9d99da3b74"}}}], "length": {"value": 0.0045077400000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "9c40129e-b9c4-4aff-b928-c2e84025b91f", "name": "l(r:p1rdt8902lv-p1rlv19164)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d1c8eb9-7f79-49ad-9e93-6c7cdcc95e22"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a02024b5-aa74-4e07-b043-a7a0e8b3e816"}}}], "length": {"value": 0.034742, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "90dd54ce-1778-49cf-a73f-6ed95b6c2526", "name": "l(r:p1rdt6537lv-p1rlv13720)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3f191ff-f8f2-4f13-af83-e67d1fdd366a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fe1a5da7-bdac-46a6-ab32-addc4f02a296"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "94cd3a09-1d25-466d-9330-f377442a7752", "name": "l(r:p1rdt6530-p1rdt6537)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40ec7437-80f0-49e8-806a-c696b1402713"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "45aca6e5-a8ee-4f45-80f3-e227379d33af"}}}], "length": {"value": 0.308478, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "55ed7480-a266-49da-beec-8b1b0d034468", "name": "l(r:p1rdt6530-p1rdt6537)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "45aca6e5-a8ee-4f45-80f3-e227379d33af"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "902291fa-9561-4f40-a4b7-4fd9fdded417"}}}], "length": {"value": 0.00557178, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "6f8d316a-82f6-4fc7-a734-a3c41faef455", "name": "l(r:p1rdt7313lv-p1rlv15628)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41e61263-feb6-4264-965a-fd1309d997a1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13eabcb1-332a-4c7a-8042-214ada721424"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "48ae8b06-1601-4570-9baa-08a0edd126d2", "name": "l(r:p1rdt7313-p1rdt7318)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e86bc267-1607-4aa3-916f-ed826b0adfdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a3a5e1c-77a2-4a9d-89e0-7d1c94176787"}}}], "length": {"value": 0.478103, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "e93ae957-665d-4d98-9565-61d7fa171d07", "name": "l(r:p1rdt7091lv-p1rlv15196)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0c42b48-7ca4-465f-b17c-048cb5f6d79b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64634ab5-a5b0-45ae-9763-7d0be029350f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "ced3202e-8eab-47a4-a979-fe58903c95a5", "name": "l(r:p1rdt5658lv-p1rlv11679)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f718935b-704d-4374-9172-856511e1eddd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4747e0f3-2a66-4e5a-8160-ac0aabe34489"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "e989189e-1d7f-413f-9447-be9c62919ce6", "name": "l(r:p1rdt5656-p1rdt5658)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f417a58d-5a47-4310-bac6-e8bb95fffc19"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81d6db26-881f-4cae-9514-df4c1e71c76e"}}}], "length": {"value": 0.6035390000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "5ba12d68-d1c2-4a66-b496-c299b151bf39", "name": "l(r:p1rdt5236-p1rdt8138)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0bab7e6b-74a6-4fe4-95e1-4ef96084f730"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22db53ea-6d9a-4527-9b36-34a4bcd2c74f"}}}], "length": {"value": 1.28532, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "3bc006be-04ae-45f9-8629-fd4cc42dcf20"}}}}, {"uuid": "76ff5ca6-d44b-4b4d-b1b5-c14739844a79", "name": "padswitch(r:p1rdt6270-p1rdt6271)p1r_14586", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "658514b3-59fd-44b7-95d6-a34cafcb47c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28954596-f060-4fa8-9f13-dfaa633bb739"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "47f16deb-bd0f-40f8-bed6-ee102cf95311", "name": "padswitch(r:p1rdt6270-p1rdt6271)p1r_14587", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b81bd5c2-96bb-445e-9eb8-d72360fd8a94"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a75c5e2-2277-42b4-87d4-6eadff5c06f1"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "fdb44f5f-12df-415f-a658-fc222a86212f", "name": "padswitch(r:p1rdt6500-p1rdt6519)p1r_14592", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9938a5c-b1cd-4592-814d-324ff2eb6644"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf648a0d-3262-4150-892b-55c3b117050a"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "6ba5defb-3101-4ef8-8d06-36719f7dad94"}}}}, {"uuid": "c2901c9f-984c-4dce-b45c-7e5ed1da1ce4", "name": "padswitch(r:p1rdt6500-p1rdt6519)p1r_14593", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5789c3b2-eb91-4e4c-85e8-24f5893e1a2c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "addd9f38-279f-4d9e-b216-38faef1940c7"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "fa89ef5e-f965-457f-a553-4831f61b03c7"}}}}, {"uuid": "111ecb31-3bbe-454e-8c3b-6d1f70eb1532", "name": "padswitch(r:p1rdt6515-p1rdt6535)p1r_14598", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acd6da90-895c-4d2c-80b4-1712b3949993"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fec078c2-a5d8-4317-a8ac-bc25772f6358"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "6ba5defb-3101-4ef8-8d06-36719f7dad94"}}}}, {"uuid": "bf3c2744-7527-4dae-99cf-5e2e7a4820ff", "name": "padswitch(r:p1rdt6515-p1rdt6535)p1r_14599", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5a05d0e-8cf2-4ab8-bdfd-24b8cd12ad67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b13053e-033e-4fe9-8eb3-89389e4bdc2b"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "fa89ef5e-f965-457f-a553-4831f61b03c7"}}}}, {"uuid": "2d52f48c-71fe-495c-a82d-13c4ed75d340", "name": "padswitch(r:p1rdt6515-p1rdt6536)p1r_14600", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0103161-4b16-4d25-a1f3-5a939317461f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04c1e05a-9cbb-4e53-9412-1cffd3976bed"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "6ba5defb-3101-4ef8-8d06-36719f7dad94"}}}}, {"uuid": "434eb627-cf53-4216-afff-7c43ac807514", "name": "padswitch(r:p1rdt6515-p1rdt6536)p1r_14601", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5aa6899b-19a2-41e6-b445-f9fe2536c8d9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f5cda74-5e33-4c52-8b2c-76bcd5e6c5cb"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "cbd826fb-5ba3-44b3-9c68-e5792dbd9854"}}}}, {"uuid": "28532c28-7be9-4805-8948-6769b876196e", "name": "padswitch(r:p1rdt6500-p1rdt6524)p1r_14594", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78b3b940-c277-441f-b2b3-83525ed85fcb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a3d9ed9-e2e4-4332-89a2-358441869830"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "d1d26e33-dcd5-4938-ad3f-174e4840c4f5", "name": "padswitch(r:p1rdt6500-p1rdt6524)p1r_14595", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97b7ef3c-ef16-4c4d-8559-722c5c67749a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ef8c502-c06f-43e5-90e6-23bd0ebcf155"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "c63cae3a-2224-4eff-aedd-06790f5bf45d", "name": "padswitch(r:p1rdt6500-p1rdt6515)p1r_14596", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1537ab1-dc7c-4bbd-b347-fc740d54fcf7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "18b822d0-cbe4-48d7-a818-87e25412d241"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "fc796329-2b2a-43b9-80c9-88427ef9b994"}}}}, {"uuid": "b26dbf8c-790a-40b5-ba1c-19b30138e3af", "name": "padswitch(r:p1rdt6500-p1rdt6515)p1r_14597", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0043b26d-8a33-4e32-a963-c4638f943775"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78b3b940-c277-441f-b2b3-83525ed85fcb"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "5f815f51-16da-46fa-b9b7-0a247327f57d", "name": "padswitch(r:p1rdt6515-p1rdt6528)p1r_14602", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ef5115d-ad7b-4671-b984-b9fd5969bf61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04c3a970-215a-4e16-a798-80496ffad438"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "a00c74d5-27a7-4365-a4b4-1caa240257e0", "name": "padswitch(r:p1rdt6515-p1rdt6528)p1r_14603", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8dcd059f-292b-4f7a-96c1-a3dc185f1eec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1537ab1-dc7c-4bbd-b347-fc740d54fcf7"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "fc796329-2b2a-43b9-80c9-88427ef9b994"}}}}, {"uuid": "f1f9def4-cddd-4b19-917f-09d63a013c98", "name": "padswitch(r:p1rdt6528-p1rdt8898)p1r_14604", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d887dbc-43bd-413e-8e72-5c95a2ed0be8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "918984ec-3b5f-4174-9bca-771bb10e0f60"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "1faec6b1-7f5b-4dcb-a048-3049e55d8b38", "name": "padswitch(r:p1rdt6528-p1rdt8898)p1r_14605", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0156ae64-03dc-4ec0-89c8-8b09a6fc9090"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ef5115d-ad7b-4671-b984-b9fd5969bf61"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "8e18082d-6d53-447e-b376-04046779e92e", "name": "padswitch(r:p1rdt6532-p1rdt8898)p1r_14606", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9f12ed7-454c-4cc9-a631-377121a07ba5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b51e96e7-2d7f-42af-9115-c9b1cfb3131c"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "2c2bcd91-cbfd-4595-aaff-70019c10c6fa", "name": "padswitch(r:p1rdt6532-p1rdt8898)p1r_14607", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "af1707bf-0b2e-4f76-96e7-c01338300d45"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d887dbc-43bd-413e-8e72-5c95a2ed0be8"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "c28bad83-c114-4053-9c9b-30bbedcabe0b", "name": "padswitch(r:p1rdt6532-p1rdt8902)p1r_14608", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f44ec9b-338a-4ae1-a26b-26422f218c13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4a0469e-1a4a-466d-b18d-f3017b6415ae"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "d6d0f63a-de65-45e9-bdee-6c551b470065", "name": "padswitch(r:p1rdt6532-p1rdt8902)p1r_14609", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f373554-9d8a-4a9c-b418-25e67fbb43a9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9f12ed7-454c-4cc9-a631-377121a07ba5"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "afa67d84-29d7-4458-849e-84ed0e1b595b", "name": "padswitch(r:p1rdt6052-p1rdt8902)p1r_14610", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c10f182d-aa76-4633-9a84-f41e20b97da1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68b101ef-d71a-44d2-b1c2-4fc5e9f62499"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "fa28c17c-346e-462b-82a7-05a8c4f9581e", "name": "padswitch(r:p1rdt6052-p1rdt8902)p1r_14611", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "468b1ce8-18fa-423b-99ca-1f3784437721"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f44ec9b-338a-4ae1-a26b-26422f218c13"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "b7883a9b-3e71-4054-8da3-871e4aca2b0d", "name": "padswitch(r:p1rdt6046-p1rdt6052)p1r_14612", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67bc3ce6-e23d-4899-b0e8-9783225338ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99e2ec8b-60fc-4a79-9eed-0d617babcb1d"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "6f1d6c03-5c03-49ba-8dab-68f7e30ab2cb", "name": "padswitch(r:p1rdt6046-p1rdt6052)p1r_14613", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49c69b43-f43b-4576-bbfa-d06b1d27de95"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c10f182d-aa76-4633-9a84-f41e20b97da1"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "6639a595-3f1b-44a9-86be-51fa881ce680", "name": "padswitch(r:p1rdt6043-p1rdt6046)p1r_14614", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "87e05b2f-c346-452c-9c72-a6db090c3124"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be3d7f84-84e7-46fc-a9ce-b3e0cf74d1d3"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "91227638-fd33-4479-9525-2d57047db981", "name": "padswitch(r:p1rdt6043-p1rdt6046)p1r_14615", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a147dd91-5597-40ff-93f9-0522ad3c726c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67bc3ce6-e23d-4899-b0e8-9783225338ff"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "689b9014-1cdc-4acc-8b3e-df03f6b21e70", "name": "padswitch(r:p1rdt6043-p1rdt6045)p1r_14616", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0396342e-2dc8-4a01-9da9-513953f9b5fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f01bba4-b8e8-45ed-af3b-1ac5a287ad46"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4900e609-ebb1-44db-852b-602449095f15"}}}}, {"uuid": "03180cf9-2727-4493-8873-aff288e916b6", "name": "padswitch(r:p1rdt6043-p1rdt6045)p1r_14617", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48d6768a-45e6-48a5-b22d-d5d418cb6221"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "87e05b2f-c346-452c-9c72-a6db090c3124"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "6d8a26df-5a49-4e47-869d-4d8122f519ba", "name": "padswitch(r:p1rdt6270-p1rdt6279)p1r_14588", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cf36152-b3af-49f7-b693-5d465db1f283"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb21415c-fc85-4197-82e5-545cb7be2ce9"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "7f30a525-3333-4b58-92ea-577806eca7df", "name": "padswitch(r:p1rdt6270-p1rdt6279)p1r_14589", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5c579309-9c05-4bae-ab97-2eca485e5ea7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "632d8db5-5220-4188-94f0-f6131253820b"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "636897ae-1c34-4ac7-a975-9d28d5b5e703", "name": "padswitch(r:p1rdt6268-p1rdt6276)p1r_14590", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "315af04d-a032-43a8-a2da-b9e68fd21f39"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b31c2adb-e4f4-4211-aac7-f317bf325d12"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "e469ce7f-3983-4e1e-8e32-aa82775148e2", "name": "padswitch(r:p1rdt6268-p1rdt6276)p1r_14591", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68d2e030-852f-44f6-9e02-d5587a1fc6a0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2f8b91d-339f-4151-90df-b0cad5c2f05a"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "7a4d0af0-a80d-4a34-9690-847471cef160", "name": "fuse(r:p1rdt5017-p1rdt5200)p1r_17536", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c09f718-9379-4281-86f6-55c46e46aec6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0843e99-e917-473c-bec7-ee0c3ddec601"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "2c1ba8d6-9c7d-4bff-8436-d9ee96d6015c", "name": "fuse(r:p1rdt5180-p1rdt5201)p1r_17572", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6316fa2-dd57-46d4-89c0-f11dd675d686"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86d3f96e-ffe2-459f-a2f1-b63d7bf138b8"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "b5dcf106-1044-4f87-a7f6-75974485309d", "name": "fuse(r:p1rdt5180-p1rdt7988)p1r_17573", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6316fa2-dd57-46d4-89c0-f11dd675d686"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "893d2436-cd6c-40ad-90af-64ba1ac23f6e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "82ed7871-cb02-4db6-91d5-ce60e7d4e1e2", "name": "fuse(r:p1rdt5472-p1rdt5476)p1r_17641", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b077dc9c-1c6f-4403-ae0c-954e7cc0c692"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d69527e6-70b6-43e2-8b9e-7c8570ad5ddf"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770"}}}}, {"uuid": "82617c5e-c2cc-455d-8527-5601ea90767d", "name": "fuse(r:p1rdt5475-p1rdt5476)p1r_17642", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b077dc9c-1c6f-4403-ae0c-954e7cc0c692"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae343ca3-3337-4528-b117-38a51e6d023f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770"}}}}, {"uuid": "ccf9e034-77fc-426b-b591-d140fef045d2", "name": "fuse(r:p1rdt5476-p1rdt5478)p1r_17643", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b077dc9c-1c6f-4403-ae0c-954e7cc0c692"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c977e6c-43f0-4d7e-b19f-82f0de97dab2"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "a4cfd253-7e2b-44c8-ad94-7e49d479f7d6", "name": "fuse(r:p1rdt5658-p1rdt5663)p1r_17692", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81d6db26-881f-4cae-9514-df4c1e71c76e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81f0e00e-bc49-448a-8e69-0569ed6a8c1a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "d9f2eb29-6d43-4a3e-97a3-82df1571da0f", "name": "fuse(r:p1rdt5658-p1rdt7070)p1r_17693", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81d6db26-881f-4cae-9514-df4c1e71c76e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02407b52-58c3-403c-9b5b-38695f435476"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "9b63d6fe-307e-4ee6-b4a9-7f9f2da30a37", "name": "fuse(r:p1rdt5650-p1rdt5662)p1r_17694", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17e89212-bc51-4fc2-83d1-4c74a285be23"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36c3c493-ff68-4bb8-a3f4-043c5f847bd3"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "30827bea-a4e8-4efe-b4d7-efcfb1e9320b", "name": "fuse(r:p1rdt6270-p1rdt6271)p1r_17809", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cf36152-b3af-49f7-b693-5d465db1f283"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "658514b3-59fd-44b7-95d6-a34cafcb47c5"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "f0933dbe-d79b-4dc5-a90e-5baecda8695c", "name": "fuse(r:p1rdt5179-p1rdt6273)p1r_17810", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d04f281-f394-432b-8b5c-cc1acb741369"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9722136-480b-44cb-8b0e-0b3165712688"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "af71c4ff-4d6e-4ab4-9d66-7d164afa30e7", "name": "fuse(r:p1rdt6278-p1rdt8439)p1r_17811", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51eefb94-724e-4dfe-9823-0f6cf8f56101"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19d5304c-574f-4646-8095-d2dcbbea86e7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "29527017-032c-4b43-bd84-238ae4b0d637", "name": "fuse(r:p1rdt6500-p1rdt6519)p1r_17854", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78b3b940-c277-441f-b2b3-83525ed85fcb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9938a5c-b1cd-4592-814d-324ff2eb6644"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "861d64ae-aba6-4135-a3ca-f177438722a2"}}}}, {"uuid": "5ba4b830-feba-4c34-9f6a-d9a4acea95aa", "name": "fuse(r:p1rdt6501-p1rdt9468)p1r_17855", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99fa55d1-867c-4db0-8697-b532da10d6d4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddfa01c0-4d12-4f96-ab50-0082ef9914a6"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "d467c779-b0de-4d04-a83b-e77928c92e89", "name": "fuse(r:p1rdt6505-p1rdt6508)p1r_17856", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e165d0d-3f13-4d87-9c4b-fdfa8829f1f3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0824c21-244b-4d4e-85d6-238ac4908b5a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "e57e9e13-5001-4417-a3f6-ab5934b145e3", "name": "fuse(r:p1rdt6509-p1rdt6514)p1r_17857", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67c889f-e940-4242-9c83-4b5ab673d8a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42f09ae1-037a-4565-9cd2-0187c45b7866"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "dd4f8c56-9e34-4519-b5c5-cbf9f9aef255", "name": "fuse(r:p1rdt6515-p1rdt6535)p1r_17861", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1537ab1-dc7c-4bbd-b347-fc740d54fcf7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acd6da90-895c-4d2c-80b4-1712b3949993"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "ab93cbf0-52fd-4d3d-a7f9-fd7cb4376fa6"}}}}, {"uuid": "f40fc1ae-26eb-4491-bdbb-89a93f0a5ed4", "name": "fuse(r:p1rdt6515-p1rdt6536)p1r_17862", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1537ab1-dc7c-4bbd-b347-fc740d54fcf7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0103161-4b16-4d25-a1f3-5a939317461f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "ab93cbf0-52fd-4d3d-a7f9-fd7cb4376fa6"}}}}, {"uuid": "2aa6f2b8-2a32-42fc-90f2-fa7a8c55098c", "name": "fuse(r:p1rdt6498-p1rdt6516)p1r_17863", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5bd908fd-8bb8-42c1-8d1b-27c4e2574450"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60b93cd6-c9fc-46ef-8b37-6b14d0773df6"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "29b3f03f-9571-4cf7-9677-dfd361d7772d", "name": "fuse(r:p1rdt6518-p1rdt9311)p1r_17864", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d39c608-5688-4e22-8ac4-96b896265274"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95d939ff-e20d-42b3-bb88-f1975f9fa0aa"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770"}}}}, {"uuid": "1b5e8967-c098-465d-af7c-c04a15173c41", "name": "fuse(r:p1rdt6510-p1rdt6523)p1r_17865", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b540c710-395d-4a35-8dc3-59d37609df09"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66b7b2e9-7658-4de0-8197-3829c6179353"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "3dfebf9a-38af-4642-a33a-d6e2ded3d3d3", "name": "fuse(r:p1rdt5728-p1rdt6537)p1r_17866", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "902291fa-9561-4f40-a4b7-4fd9fdded417"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66ef2ffb-e67d-47eb-ae59-194c538ab861"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "99c97fbd-6df7-451e-8cda-f3cbb38af5c8", "name": "fuse(r:p1rdt7036-p1rdt7091)p1r_17967", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6372a592-5e2d-41c8-819b-f56bfbb58e19"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28d17238-8db8-41da-960c-317183423576"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "43c81b03-5700-4da4-8f70-67963aaef0ac", "name": "fuse(r:p1rdt7298-p1rdt7313)p1r_17994", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a3a5e1c-77a2-4a9d-89e0-7d1c94176787"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1f6ad7d-f7ea-4b94-956c-ec4a3b2028d5"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "5536ecf7-d8e7-4008-b350-e418d4c32378", "name": "fuse(r:p1rdt7554-p1rdt7570)p1r_18045", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9b94106-b7c5-4ce9-9c19-053487848c2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2bdb2b51-0526-4995-bb5e-a2bd495488d4"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "6013789b-d1a7-4068-b10a-f2499431a3e3", "name": "fuse(r:p1rdt7559-p1rdt7570)p1r_18046", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9b94106-b7c5-4ce9-9c19-053487848c2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09814176-7891-4fe1-addf-b47aa106c40d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "8c46219e-0ca9-4c62-b0d1-27774f373511", "name": "fuse(r:p1rdt7551-p1rdt7574)p1r_18047", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd487832-bc77-406f-a995-4b099fad7c64"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1d8c14d0-8247-4a44-98c1-4534aa9037a2"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770"}}}}, {"uuid": "15bcd57b-3325-4415-8d0c-e10363a4d084", "name": "fuse(r:p1rdt7553-p1rdt7574)p1r_18048", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd487832-bc77-406f-a995-4b099fad7c64"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f00dd033-8e7c-43af-bd16-1de2954e07be"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "cbed5d9f-5e20-4900-b098-41ced4f2e4c7", "name": "fuse(r:p1rdt7599-p1rdt8492)p1r_18054", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a086b782-3a8d-44e9-9948-cb7f051219e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "605c34bc-3f7c-4eb7-8df0-fcd00d261921"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "87a1de9d-91b1-4052-ab8c-9c01790a77d8", "name": "fuse(r:p1rdt6847-p1rdt7624)p1r_18055", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e240270-762d-49f0-a4e4-29fcd6273ce5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be9350ab-7ad2-4a89-a374-94bf69588d7f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "a063cb46-3701-476f-b259-2890451a38db", "name": "fuse(r:p1rdt7617-p1rdt7625)p1r_18056", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3e6cbe9-d1d3-4c59-981f-dad980f0999b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a11cf3d9-90bb-4de8-b637-6ec9128525ec"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "fc77f72a-a5f7-465d-aa39-93591b6b0878", "name": "fuse(r:p1rdt7621-p1rdt7625)p1r_18057", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3e6cbe9-d1d3-4c59-981f-dad980f0999b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53df7b6e-bd8c-43f2-860d-8869aec5d079"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "d64e4be1-0395-4089-96bf-26178c53784e", "name": "fuse(r:p1rdt7625-p1rdt7631)p1r_18058", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3e6cbe9-d1d3-4c59-981f-dad980f0999b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "460f5de9-8d4f-468a-b67a-b3b05354a9ce"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "09949c3d-86ce-4fb6-a416-b2b63b50edc5", "name": "fuse(r:p1rdt7576-p1rdt8151)p1r_18146", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c794942-d5ce-481f-9c6a-563a2180a4ba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a31fa2-4df8-418a-a215-d0d450ced9a3"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "f0e0af75-4597-4f6c-930a-4e193179b902", "name": "fuse(r:p1rdt8151-p1rdt8155)p1r_18147", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c794942-d5ce-481f-9c6a-563a2180a4ba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0a6628e-afc1-4daf-8a29-7626ac2aa5dd"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "fb5f1e22-94af-4dc6-89b5-0b586358c8cb", "name": "fuse(r:p1rdt8405-p1rdt8445)p1r_18212", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60829dab-c129-4017-961a-81435d8afa93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8c69243-872f-4e25-9d03-82692bbf8779"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "70b85fee-d939-41de-9968-944ff2b25094", "name": "fuse(r:p1rdt8414-p1rdt8456)p1r_18215", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b48f78d-1092-4536-bfb3-029da6a70dff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34054ef8-8942-4471-ac14-43c6a37e5a16"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "85454510-f466-49d9-93d2-1381c0acd28a", "name": "fuse(r:p1rdt6347-p1rdt8470)p1r_18224", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "442de065-9e2a-4ff8-9100-1298d3fe0f6f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6163371c-55ef-4900-a3ef-2e4e8fc2894a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "d0487dc6-e327-4fb9-8124-bce8e04cfc95", "name": "fuse(r:p1rdt7268-p1rdt8470)p1r_18225", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "442de065-9e2a-4ff8-9100-1298d3fe0f6f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6225b33-2abc-4f77-9d65-459794f56353"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "4a4594e8-f914-4990-ba21-6c90a130e917", "name": "fuse(r:p1rdt8901-p1rdt8902)p1r_18292", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f44ec9b-338a-4ae1-a26b-26422f218c13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d21061fa-1011-44f7-8a20-26fcf0550f52"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "861d64ae-aba6-4135-a3ca-f177438722a2"}}}}, {"uuid": "c53f224c-161b-4771-a189-43944175e441", "name": "fuse(r:p1rdt8902-p1rdt9377)p1r_18293", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f44ec9b-338a-4ae1-a26b-26422f218c13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43c862de-b014-4b24-8b34-54dae6edcf5a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "861d64ae-aba6-4135-a3ca-f177438722a2"}}}}, {"uuid": "6f8f40b9-00fa-445b-a260-2f2b7058d7fb", "name": "fuse(r:p1rdt6581-p1rdt9084)p1r_18331", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4251587d-600f-40a0-9aec-229fb2e3f2df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6114624f-81c8-4d9c-8f9a-3ab73158596e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "198bb22e-539d-4ad2-99eb-c99330a282b0", "name": "fuse(r:p1rdt9076-p1rdt9084)p1r_18332", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4251587d-600f-40a0-9aec-229fb2e3f2df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12b4dc99-fe50-457c-90aa-48a2fb19ebf1"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "db412f85-aaee-44e6-b2f7-6c05006c4a3f", "name": "fuse(r:p1rdt7790-p1rdt9090)p1r_18334", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52c72b52-1c6c-46f6-adbe-1054eb233c20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15a7847f-aa96-4206-b4c6-422802f4e0a6"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "e8b8932b-1bea-473d-b138-d323af891be4", "name": "fuse(r:p1rdt9090-p1rdt9091)p1r_18335", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52c72b52-1c6c-46f6-adbe-1054eb233c20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf719d10-8168-4d80-894e-1b1516f033e8"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "36b7e8e3-1a5f-4604-9ffe-b88b6a71ea45", "name": "fuse(r:p1rdt6226-p1rdt9333)p1r_18385", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0da91bf8-b687-47df-a7dc-41e6166fd667"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f6d3fab-3b83-40c9-85c4-cfeddd0d317a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "3bf77ce1-4f77-4f4c-902e-9b4293967914", "name": "fuse(r:p1rdt9469-p1rdt9470)p1r_18407", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3fd32c7-2866-4699-93a8-dd3a9997d349"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5f6a2ec-3ddd-4ba7-9c55-88b4d82e7735"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "7d4a8786-91d9-4845-8fe5-8e8f350b4a94", "name": "fuse(r:p1rdt5730-p1rdt9479)p1r_18410", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b006c3-79f8-4a27-b76a-d1b458ff2a21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e07d8bc1-2f8a-4067-a2a7-b903dd042ce3"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "8b1e7929-00be-4710-9892-83b9f936f05c", "name": "fuse(r:p1rdt5840-p1rdt9479)p1r_18411", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b006c3-79f8-4a27-b76a-d1b458ff2a21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7f9286b-4209-402a-a365-1d27da4efb75"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "2c304709-0eb6-47d1-aa82-ab4b517d007e", "name": "recloser_disswitch(r:p1rdt8802-p1rdt9413)p1r_20691", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f750e531-5ade-40a9-9bb0-042220ce9807"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "401576cc-4ad6-42cd-bf1c-4022da720711"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "140f67fe-0cf8-45a3-8e1d-7cd225dab6f1"}}}}, {"uuid": "84d72fc4-99d1-4474-99ef-ab56621f28e6", "name": "goab_disswitch(r:p1rdt5236-p1rdt5342)p1r_20760", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c8f9ea6-06fb-4fd0-8629-ceea4f32189f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9bbfae79-a578-4ff2-b622-3dddd9859ac8"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "1848ee60-41cc-4072-ae7a-8f2e890e75ff", "name": "goab_disswitch(r:p1rdt6531-p1rdt7307)p1r_20862", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "385eabe4-8c8e-4354-96ec-931e6c25574d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8431ef4c-78dd-4a39-b15a-95818cfe1d86"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "60e69ce7-f8f6-4852-ae1e-694ae07f37f5", "name": "recloser_disswitch(r:p1rdt8405-p1rdt9413)p1r_20975", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f750e531-5ade-40a9-9bb0-042220ce9807"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16ecb938-cd0c-4be5-a915-be0d84d351f2"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "140f67fe-0cf8-45a3-8e1d-7cd225dab6f1"}}}}, {"uuid": "bb69f156-d7c0-40a5-87e3-b6c622faea56", "name": "goab_disswitch(r:p1rdt6208-p1rdt8805)p1r_20999", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3444af6b-f9d4-4229-b6b2-2114300c3f94"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "89f0c671-9d27-4dec-bd37-dc6c56f07e5d"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "b7056dc9-d1ea-4fc2-a609-6d09d60d3fac", "name": "goab_disswitch(r:p1rdt6517-p1rdt6523)p1r_21014", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b540c710-395d-4a35-8dc3-59d37609df09"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "608945f2-9b19-43bc-83d9-0fe8787b06b4"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "c505d68e-64f2-48ac-afb2-f29694bbaa79", "name": "disswitch(r:p1rdt5195-p1rdt5202)p1r_21153", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97e4f179-9d60-4183-8326-eb0ab98a53eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "227d848c-cddc-4561-996b-f8f7a60a5a89"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "ee8a464c-5fc6-41d0-9c41-36add8ffa204", "name": "goab_disswitch(r:p1rdt8160-p1rdt8161)p1r_21295", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25946c74-15c2-412c-baed-8de5f7aecf98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8ecbd5b-6db5-44a0-b2a8-0233d4eb5b20"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "0799b34e-32a2-4275-b73b-5d5b98a2674b", "name": "goab_disswitch(r:p1rdt4980-p1rdt5183)p1r_21308", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ddb0629-4947-47ca-83f9-9b7c073db235"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35487e15-57cb-4e19-bef7-49074e5eb9ee"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "ca277d25-50a6-4bf9-becf-59896b3145c3", "name": "l(r:p1rdt6501-p1rdt9468)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e4fd2ed-daa1-4a22-936f-8d51ee928d99"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "edf27f1d-b486-434e-92be-963bdeb26090"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "40a26197-da2a-4e22-a50a-3922efd7762c"}}}}, {"uuid": "22c44cd1-4a06-4e8d-9f99-9f622360b34c", "name": "l(r:p1rdt6501-p1rdt9468)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "edf27f1d-b486-434e-92be-963bdeb26090"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b5695dd-714e-4de1-a63a-f142ff0460e1"}}}], "length": {"value": 0.907254, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e3949704-59de-4ac0-a856-a028f2766fb2", "name": "l(r:p1rdt8902-p1rdt9377)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32e86968-974e-4bcc-b562-1d4209771cf0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e62ba05d-920f-4f55-b1c6-3aa078e0073d"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "40a26197-da2a-4e22-a50a-3922efd7762c"}}}}, {"uuid": "f111d805-c7d0-4e6b-beee-74b482cec4f6", "name": "l(r:p1rdt8902-p1rdt9377)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e62ba05d-920f-4f55-b1c6-3aa078e0073d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61972a50-ce24-4ec1-8535-402665b55a55"}}}], "length": {"value": 1.557306, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3a055c24-acdd-4c3d-8cc6-653f0d8be826", "name": "l(r:p1rdt5195-p1rdt5653)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fbc486eb-4f08-4602-a101-1298d4a46b32"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ccc9dcb-3a72-4f11-9bcf-e3a7f1a21985"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "40a26197-da2a-4e22-a50a-3922efd7762c"}}}}, {"uuid": "313717c1-fa7c-4f6e-b27e-12c06e71e69e", "name": "l(r:p1rdt5195-p1rdt5653)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ccc9dcb-3a72-4f11-9bcf-e3a7f1a21985"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "769c14db-ac3f-438d-9f7d-c7eb2d3074b5"}}}], "length": {"value": 0.915894, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4399bb4b-ec3f-463a-b5d0-16570e8eb9b9", "name": "l(r:p1rdt28lv-p1rlv51)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b3c997d-cd47-439c-aeb9-326e12c2b869"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ccef6af-4bf6-44dc-b292-2bf9503a374a"}}}], "length": {"value": 0.0198886, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4aaad3fe-4de0-4afb-8264-3875d74a560e", "name": "l(r:p1rdt28lv-p1rlv53)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b3c997d-cd47-439c-aeb9-326e12c2b869"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3c62646-6132-41ef-ba14-a06789885cd5"}}}], "length": {"value": 0.0198886, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d32a111a-c62d-4052-bf39-48c43dab30fb", "name": "l(r:p1rdt29lv-p1rlv52)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61fc3980-6aa4-415c-91c1-10d32c7c359c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fec0a162-4b0c-4577-b878-8dbc7c9935fc"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "537e8b73-0d40-4f17-a28d-0aae6b098e14", "name": "l(r:p1rdt30lv-p1rlv62)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d2be3b5-dbfc-4099-af9a-96368e60fe23"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "346dad85-3bf8-41a6-97ea-6b3b40a7f22e"}}}], "length": {"value": 0.028845, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "85b7ab92-76f2-4b11-843c-08ecd9d88d3d", "name": "l(r:p1rdm56-p1rlv54)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c89ec162-cda3-4c40-8833-3fff085538ba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20010301-32ce-4cc0-ab59-04ef3bcd35d7"}}}], "length": {"value": 0.0170492, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ddaa35ee-6a95-4aea-8dd8-4c94f1fce2c3", "name": "l(r:p1rdm56-p1rdt30lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d2be3b5-dbfc-4099-af9a-96368e60fe23"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c89ec162-cda3-4c40-8833-3fff085538ba"}}}], "length": {"value": 0.0189193, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9b7fb251-9269-4d78-8c55-47059d037541", "name": "l(r:p1rdm58-p1rlv55)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59ff3c1b-38f4-4a33-86fa-e956951c0f2c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36bdbc4e-edfa-425a-8e4c-e6123b567555"}}}], "length": {"value": 0.013887, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "859a2d9c-f5ee-4913-8ea2-6fdfbcfab2b9", "name": "l(r:p1rdm60-p1rlv152)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f678ceb4-b717-44a5-9db9-f698bece6935"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25b891ce-797a-4a4d-b664-4225fba806c4"}}}], "length": {"value": 0.0140747, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "aa7cc74b-1797-4884-9885-e3500e2380d9", "name": "l(r:p1rdm58-p1rdm60)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59ff3c1b-38f4-4a33-86fa-e956951c0f2c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f678ceb4-b717-44a5-9db9-f698bece6935"}}}], "length": {"value": 0.0566856, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7fb3cf19-7676-4fc4-ab81-0e769d75d414", "name": "l(r:p1rdm58-p1rdt31lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3510eedd-535c-4e58-b81e-c5ec09030479"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59ff3c1b-38f4-4a33-86fa-e956951c0f2c"}}}], "length": {"value": 0.0140094, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d9c6db05-7bc3-4ad3-84d9-f60e07fa7a5f", "name": "l(r:p1rdm59-p1rlv58)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a0a4841-bf31-4498-98d9-115cc159981c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a32ee184-f677-4333-b7ee-7bc30ab41467"}}}], "length": {"value": 0.0220532, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "19418b76-199d-4da4-a457-d31bd2cc8bd2", "name": "l(r:p1rdm59-p1rdt31lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3510eedd-535c-4e58-b81e-c5ec09030479"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a0a4841-bf31-4498-98d9-115cc159981c"}}}], "length": {"value": 0.0494128, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8b247c95-6202-4fe5-940d-4492e1bffb6c", "name": "l(r:p1rdt32lv-p1rlv414)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e374d6d6-1e75-4808-b65a-c7033e1bd528"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec2c1edd-78b1-4436-85cc-2fbc7d880b87"}}}], "length": {"value": 0.00981453, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f0dff6bc-98c3-4316-b25d-c48ba2181493", "name": "l(r:p1rdm61-p1rlv56)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cef7aa37-7ca0-4130-9bcd-1804a811245a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4694811a-ba43-4c78-b957-5209b1d961e2"}}}], "length": {"value": 0.0329346, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3bbc54a5-ff57-420e-b9f4-554e9a130e80", "name": "l(r:p1rdm61-p1rdt32lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e374d6d6-1e75-4808-b65a-c7033e1bd528"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cef7aa37-7ca0-4130-9bcd-1804a811245a"}}}], "length": {"value": 0.0318291, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6fc81b07-6ca8-4ea4-8296-3a5318abe131", "name": "l(r:p1rdt33lv-p1rlv170)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "065c8583-45e5-466c-b4c0-1c66bf970abe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f7dbd18-1cbe-49d3-b490-3c46cf8e37f1"}}}], "length": {"value": 0.0380059, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "16b7dcf9-eccc-4d50-bf94-8699ecae0e2f", "name": "l(r:p1rdm63-p1rlv57)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0538c66-18d7-440e-9efd-6b2945d50f2b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "925cb3b7-4ced-4a36-913f-e6851ed79b98"}}}], "length": {"value": 0.030867800000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2bdd73c1-d6c6-46df-925e-e5b975ebcf7e", "name": "l(r:p1rdm63-p1rdt33lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "065c8583-45e5-466c-b4c0-1c66bf970abe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0538c66-18d7-440e-9efd-6b2945d50f2b"}}}], "length": {"value": 0.0345517, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "83b76af1-5305-4dbc-bb4d-1ae26fa9de1d", "name": "l(r:p1rdm64-p1rlv61)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfa2eaff-b163-46ce-b6e5-516680d39bc3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d22bf2f5-74cc-47c7-ae3b-410fba27c113"}}}], "length": {"value": 0.0241386, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3898954b-b312-40ab-ac32-628c8dce2ca0", "name": "l(r:p1rdm64-p1rdt33lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "065c8583-45e5-466c-b4c0-1c66bf970abe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfa2eaff-b163-46ce-b6e5-516680d39bc3"}}}], "length": {"value": 0.0177518, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "02917748-21d7-4d1d-ba3e-9a59a7f04498", "name": "l(r:p1rdm66-p1rlv59)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72ee0111-4849-4280-b3c9-c0627d1a6c09"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b80bdb24-4bbf-4a57-bd5f-6a5ec9d484dd"}}}], "length": {"value": 0.024402100000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a261116f-a80b-4209-9176-cbc942356177", "name": "l(r:p1rdm66-p1rdt34lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "553a6868-acec-4492-a52d-5aa08414c612"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72ee0111-4849-4280-b3c9-c0627d1a6c09"}}}], "length": {"value": 0.0174345, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "efad20b9-c489-41bc-9b18-f645e0471962", "name": "l(r:p1rdm67-p1rlv67)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "713c1538-ceb4-46df-a996-6c591c0f8e40"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64a67ed2-a563-4378-b6ac-d9a95339e862"}}}], "length": {"value": 0.0188395, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "068b2a22-12d1-4431-9876-767c11d1380a", "name": "l(r:p1rdm67-p1rdt34lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "553a6868-acec-4492-a52d-5aa08414c612"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "713c1538-ceb4-46df-a996-6c591c0f8e40"}}}], "length": {"value": 0.009885930000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "57f5dec5-fde4-48bd-927b-f6e8e3ee8902", "name": "l(r:p1rdt35lv-p1rlv60)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f98cc066-fca3-4489-9770-047caee3e742"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7eb0d1e8-f85e-493e-b69b-26437fdb8ad9"}}}], "length": {"value": 0.0469606, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "dab845c7-99b1-4cc4-8b7b-5a2a0dd8bc4c", "name": "l(r:p1rdm69-p1rlv65)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23861598-ab3c-4648-9de9-3ee4316f2cb4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e00fd9b-92b3-49c4-bcc2-957b9d2c7bad"}}}], "length": {"value": 0.0500401, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "46a3c80f-7d6c-48a5-8c7e-9fbd9a1b6494", "name": "l(r:p1rdm69-p1rdt35lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f98cc066-fca3-4489-9770-047caee3e742"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23861598-ab3c-4648-9de9-3ee4316f2cb4"}}}], "length": {"value": 0.0188806, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9b42fd7d-449c-4d4e-adea-0857666843b0", "name": "l(r:p1rdt36lv-p1rlv63)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a4fb658-c3ba-428a-82bf-b38ae68dd908"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8300f90c-9a3b-400d-af04-072125dce84f"}}}], "length": {"value": 0.0205644, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b4da0dcf-1635-44fc-9cfa-33fecce7b0c4", "name": "l(r:p1rdm71-p1rlv64)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "074f23bd-2fb2-4480-ae4b-f1c1f754613e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5efd07ee-012a-40a4-97bb-07c1a5ed898c"}}}], "length": {"value": 0.0292333, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6bf40a82-f525-451a-b200-2331216a8321", "name": "l(r:p1rdm72-p1rlv162)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "590e467f-47a6-4c7e-ae3a-83cec8dd87e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3fcd1ee-e6e0-4ca3-aacf-cc527b07482a"}}}], "length": {"value": 0.0254773, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "11fdc903-3137-4c9b-940d-6dfaefc83a72", "name": "l(r:p1rdm71-p1rdm72)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "074f23bd-2fb2-4480-ae4b-f1c1f754613e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "590e467f-47a6-4c7e-ae3a-83cec8dd87e3"}}}], "length": {"value": 0.0457287, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1bba3325-6f85-4fd1-8d29-a1bf18d1c001", "name": "l(r:p1rdm71-p1rdt37lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90a16370-67f7-4abd-992c-990d1eb8f17e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "074f23bd-2fb2-4480-ae4b-f1c1f754613e"}}}], "length": {"value": 0.0378897, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1e35ea63-0b7a-4e0b-b5fa-533a1e06f848", "name": "l(r:p1rdm73-p1rlv457)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35807695-5d6d-4544-a748-a96c56b705d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6278f6ee-7332-4de8-9d2c-83bb637f489f"}}}], "length": {"value": 0.020988, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a802ba01-a073-46dc-a10c-aa18ea2dbc0e", "name": "l(r:p1rdm73-p1rdt37lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90a16370-67f7-4abd-992c-990d1eb8f17e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35807695-5d6d-4544-a748-a96c56b705d1"}}}], "length": {"value": 0.0568504, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "70ad305b-4b65-4e83-8e65-943e35a8510a", "name": "l(r:p1rdm74-p1rlv66)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "352f8404-f923-468a-92a5-1be2f82ffb97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e90eb8a2-5db0-4861-96ef-a6991a0386eb"}}}], "length": {"value": 0.0137711, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5adb5955-448c-40e5-95ec-8933d9be1689", "name": "l(r:p1rdm74-p1rdt38lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "752aca33-7682-4e8c-a8b1-624467e02958"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "352f8404-f923-468a-92a5-1be2f82ffb97"}}}], "length": {"value": 0.0186134, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "851de1c3-1505-4685-909f-6eddfe850ab2", "name": "l(r:p1rdm75-p1rlv68)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2332f175-22ca-4894-b63d-246f5c11c572"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c22aa2c8-a6fc-4b27-a875-e07e3f50ecac"}}}], "length": {"value": 0.0220855, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "eb01a68d-63ea-47e1-a68a-7afd7773560d", "name": "l(r:p1rdm75-p1rdt38lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "752aca33-7682-4e8c-a8b1-624467e02958"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2332f175-22ca-4894-b63d-246f5c11c572"}}}], "length": {"value": 0.0568453, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c0d8734c-4318-43b0-9e1e-c11ab3c1271b", "name": "l(r:p1rdm76-p1rlv69)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "131099af-6f69-4531-bebf-e457ff5d7624"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "876ffb0b-f33c-45b2-a085-7b34103ecffc"}}}], "length": {"value": 0.0355524, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "145e3aee-da52-4de2-a9a0-0cf95e1a2b11", "name": "l(r:p1rdm76-p1rdt39lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "623ec6b4-cb70-4437-9d79-5ec577bc3199"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "131099af-6f69-4531-bebf-e457ff5d7624"}}}], "length": {"value": 0.0177535, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "06a16ec9-6153-49da-a2be-542e268a7b4b", "name": "l(r:p1rdm77-p1rlv70)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a909c826-1682-47f0-926c-0a67c9ff2a3a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e53e7714-06d1-4f85-89c5-f152629e8ab7"}}}], "length": {"value": 0.0326608, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f396975a-7f86-4dd3-ad16-b797849c3c9b", "name": "l(r:p1rdm77-p1rdt39lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "623ec6b4-cb70-4437-9d79-5ec577bc3199"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a909c826-1682-47f0-926c-0a67c9ff2a3a"}}}], "length": {"value": 0.0177617, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5a53052c-73d6-4ee8-a0c2-559a73722330", "name": "l(r:p1rdt40lv-p1rlv143)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d08444c-79a3-4ba0-8c69-1855a600dea0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "46cd88d0-b2c4-492a-af3d-d9ae886d0089"}}}], "length": {"value": 0.016125500000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "482a0e0c-58d8-4958-aba7-344577c6f03f", "name": "l(r:p1rdm78-p1rlv71)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "435b1814-b0a6-40e3-a446-efe5b7fce133"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d7791de-0cf6-4901-8b95-2d67870f09f5"}}}], "length": {"value": 0.025679000000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2656656a-d2e7-49e3-9554-4cfd0e1b3ca5", "name": "l(r:p1rdm78-p1rdt40lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d08444c-79a3-4ba0-8c69-1855a600dea0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "435b1814-b0a6-40e3-a446-efe5b7fce133"}}}], "length": {"value": 0.0167754, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f87e81cc-c8a8-40ae-8e3f-0ac8561cdefe", "name": "l(r:p1rdt41lv-p1rlv72)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "793d0bf4-4d9f-4df4-bc95-d528dd7d31d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc710fc3-ae5f-478e-997b-85467db7c93c"}}}], "length": {"value": 0.02597, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e52746d2-07d5-4974-a61e-ff8b224c2504", "name": "l(r:p1rdt41lv-p1rlv88)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "793d0bf4-4d9f-4df4-bc95-d528dd7d31d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "188047cd-3f14-4240-91fe-30113d48152b"}}}], "length": {"value": 0.00984838, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6b64c3a9-ba1b-4cdf-ad7f-e5db328b835d", "name": "l(r:p1rdt42lv-p1rlv86)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8fb27dc9-b404-49d1-84dd-0cde418b037d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "540e0121-fc39-4c2c-9fbc-012c020f5994"}}}], "length": {"value": 0.0169027, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f58b52b9-f373-436c-9298-a94f37865466", "name": "l(r:p1rdm82-p1rlv73)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5f4300c-037f-42b5-a390-31ec1e8396b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4e2991c-1404-44da-bbb5-5a2ebc43bde4"}}}], "length": {"value": 0.025469700000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fd2626d9-6e6e-40a6-b779-ae761e65eaac", "name": "l(r:p1rdm86-p1rlv108)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5696ebea-257d-4cc1-9ae4-61c98563b706"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "afc70b80-ab76-440c-b05b-149458051675"}}}], "length": {"value": 0.05240000000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4cd09994-2b8e-4ac2-b56f-ee68addc1a41", "name": "l(r:p1rdm82-p1rdm86)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5f4300c-037f-42b5-a390-31ec1e8396b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5696ebea-257d-4cc1-9ae4-61c98563b706"}}}], "length": {"value": 0.0153424, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7708cca7-aa53-4b77-befd-c39e45b72c32", "name": "l(r:p1rdm82-p1rdt42lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8fb27dc9-b404-49d1-84dd-0cde418b037d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5f4300c-037f-42b5-a390-31ec1e8396b3"}}}], "length": {"value": 0.0153436, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e84c77e4-d941-4bb3-8e2f-0af560052a45", "name": "l(r:p1rdm83-p1rlv75)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49a07eb5-9c9b-479c-a345-b09f72725a21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ef51371-3fa2-400a-a2b4-3afa97ff2419"}}}], "length": {"value": 0.0103792, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "927bf580-0b67-4304-a620-9bc0dbd749e8", "name": "l(r:p1rdm83-p1rlv130)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49a07eb5-9c9b-479c-a345-b09f72725a21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5c96953-6710-4765-b5bd-4359e03e4c63"}}}], "length": {"value": 0.0354711, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "5634d407-bc77-4db0-b887-faa3d8d89dfd", "name": "l(r:p1rdm84-p1rlv79)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae45c08d-f629-4ff9-9c23-838b6e34da88"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4dd2283-6100-48ce-b4bc-0e37b7b4e409"}}}], "length": {"value": 0.0190078, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ead30048-de23-480f-aaa4-ed9fe5b1fc46", "name": "l(r:p1rdm87-p1rlv115)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d93360fa-3106-4444-9488-e73c6997ab71"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "919a48e8-b378-4dd5-8e33-a2602fb58bc0"}}}], "length": {"value": 0.0121631, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9d97061e-2727-4ac2-b9bf-80ebbfc55484", "name": "l(r:p1rdm84-p1rdm87)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae45c08d-f629-4ff9-9c23-838b6e34da88"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d93360fa-3106-4444-9488-e73c6997ab71"}}}], "length": {"value": 0.0078607, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "53544628-331d-4655-91a4-0552645c049b", "name": "l(r:p1rdm83-p1rdm84)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49a07eb5-9c9b-479c-a345-b09f72725a21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae45c08d-f629-4ff9-9c23-838b6e34da88"}}}], "length": {"value": 0.0149995, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1ac77898-6235-494c-b7f1-3d2c55ee09bb", "name": "l(r:p1rdm83-p1rdt42lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8fb27dc9-b404-49d1-84dd-0cde418b037d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49a07eb5-9c9b-479c-a345-b09f72725a21"}}}], "length": {"value": 0.0149938, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d4818ca2-9988-4682-8047-75b4f8e1b705", "name": "l(r:p1rdm90-p1rlv117)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b812c54c-1689-47cf-beba-55faea943380"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e6de569-7f61-439e-a402-850c4f071ab3"}}}], "length": {"value": 0.0134175, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "41a7ab78-9dfe-4430-89b0-f3ba5c13ff28", "name": "l(r:p1rdm90-p1rdt43lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "274aa0ec-f229-454c-b52d-23130bacb97e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b812c54c-1689-47cf-beba-55faea943380"}}}], "length": {"value": 0.0542235, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6bfac725-d1e2-41cf-ad2e-86634eae8994", "name": "l(r:p1rdm91-p1rlv137)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c82df28-72fa-4cf0-a844-8a6bf90e548b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54ca5205-5b71-42f2-8e24-c24f768a7a5c"}}}], "length": {"value": 0.0263424, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c4bc0a7f-44b6-4f0d-976c-999ec209e06f", "name": "l(r:p1rdm89-p1rlv74)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acbf36c3-9c53-417f-98c1-fa1b5d4b60f4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5861410e-9d6d-423e-b967-2f2af65610b8"}}}], "length": {"value": 0.0187311, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "83961bfa-b775-448b-8caf-405871623580", "name": "l(r:p1rdm89-p1rdm91)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c82df28-72fa-4cf0-a844-8a6bf90e548b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acbf36c3-9c53-417f-98c1-fa1b5d4b60f4"}}}], "length": {"value": 0.0145778, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d8f254e6-7113-400b-92d5-364565ba1e80", "name": "l(r:p1rdm91-p1rdt43lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "274aa0ec-f229-454c-b52d-23130bacb97e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c82df28-72fa-4cf0-a844-8a6bf90e548b"}}}], "length": {"value": 0.0145786, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "db357783-b1b2-4ffd-aca8-8ab881b6c351", "name": "l(r:p1rdt44lv-p1rlv76)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c813f8a2-226b-431d-a41a-195cf5e8b01a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3354497f-6de7-405d-9fca-a9c77463dc27"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "82e7c04e-ab13-4355-9b05-434f456065ad", "name": "l(r:p1rdm93-p1rlv77)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5151d03-c8b3-41f2-a2cd-743aa8ea0fea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f88a22a3-7e6c-4fc5-a8f4-a08cdaa3f5d6"}}}], "length": {"value": 0.0172005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ce7f90cf-c8da-460b-8111-0ea157b77973", "name": "l(r:p1rdm94-p1rlv119)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4dece5f0-ab6c-40ed-9ec6-0b1377d19e78"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee33d90b-2f70-4c9d-863d-6486b95280b8"}}}], "length": {"value": 0.0199779, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bd47d45f-500c-4c3d-8678-51a92d9023ea", "name": "l(r:p1rdm93-p1rdm94)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5151d03-c8b3-41f2-a2cd-743aa8ea0fea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4dece5f0-ab6c-40ed-9ec6-0b1377d19e78"}}}], "length": {"value": 0.0237669, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e1298125-2403-434a-b2db-9f772bc576f3", "name": "l(r:p1rdm93-p1rdt45lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e276abc-bb27-47e4-9de8-adaccbf964dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5151d03-c8b3-41f2-a2cd-743aa8ea0fea"}}}], "length": {"value": 0.0199888, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "96d5897f-f166-4bb2-8b66-3b7ba676cfe2", "name": "l(r:p1rdm95-p1rlv132)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a363b9b6-b80f-42cf-942e-17e723376ae6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41960437-e2e6-4746-89c2-81c81602ca1b"}}}], "length": {"value": 0.027088, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "79f574f4-b9a5-43f9-ab40-01e7afbc43b6", "name": "l(r:p1rdm95-p1rdt45lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e276abc-bb27-47e4-9de8-adaccbf964dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a363b9b6-b80f-42cf-942e-17e723376ae6"}}}], "length": {"value": 0.0399682, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "93d914a2-0ec3-414d-9502-25ee2a4943eb", "name": "l(r:p1rdm96-p1rlv78)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e93e7ed-6686-4fb2-8410-867f2cdbdab2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae76f058-b79a-4c0f-90be-f9cd7a02bcfc"}}}], "length": {"value": 0.032544800000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3e22d8ca-5f4b-48ed-afc3-1da29b5dce45", "name": "l(r:p1rdm97-p1rlv87)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdd576f2-a7e2-46eb-b2b0-818c4a97e694"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "46ee0e6c-daf7-4412-94a7-5332a6a97656"}}}], "length": {"value": 0.029464900000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e72d832f-a10c-4a41-bce6-db90e6a066d2", "name": "l(r:p1rdm96-p1rdm97)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e93e7ed-6686-4fb2-8410-867f2cdbdab2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdd576f2-a7e2-46eb-b2b0-818c4a97e694"}}}], "length": {"value": 0.0168832, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8cfe93c7-253e-4b6b-b392-aea42b09d08e", "name": "l(r:p1rdm96-p1rdt46lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aacdcb46-43e3-4147-ac25-3a9c1223e13a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e93e7ed-6686-4fb2-8410-867f2cdbdab2"}}}], "length": {"value": 0.018235, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "78991428-108e-4d6c-9398-41e4ca9a49db", "name": "l(r:p1rdm98-p1rlv138)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70024d6c-94dd-4367-aeec-92d4bc5eec04"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea9e5f8c-8477-403c-9d3a-911c4e5ab5c8"}}}], "length": {"value": 0.0236773, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c3c52273-2722-4a97-bd10-8e3dd59685c4", "name": "l(r:p1rdm98-p1rdt46lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aacdcb46-43e3-4147-ac25-3a9c1223e13a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70024d6c-94dd-4367-aeec-92d4bc5eec04"}}}], "length": {"value": 0.0547245, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d216af78-c172-4a19-a303-41195ec88d64", "name": "l(r:p1rdt47lv-p1rlv80)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f031530a-b3fc-4f8e-b0ac-139009d1256c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab7e1b4a-f8ec-4211-b7a0-d7f9057f576a"}}}], "length": {"value": 0.0117312, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "97d48ab3-ae67-4bb4-9933-c573d3b1b708", "name": "l(r:p1rdt47lv-p1rlv92)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f031530a-b3fc-4f8e-b0ac-139009d1256c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db8f484a-94d5-4d20-8ebf-6708b1601a0d"}}}], "length": {"value": 0.0191133, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "496ae067-3834-4768-96cc-4f91d6de96f4", "name": "l(r:p1rdt48lv-p1rlv81)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f1790fe-a399-46e3-b9e3-5979837777ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef92e40c-fe3c-4f7f-b844-884e1079e491"}}}], "length": {"value": 0.0151262, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "42788906-ee7c-4cb5-8863-6cdb7c3c583f", "name": "l(r:p1rdt48lv-p1rlv120)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f1790fe-a399-46e3-b9e3-5979837777ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a02925cd-7c5b-475f-9e91-30d639bb3c33"}}}], "length": {"value": 0.018014, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e6aee435-bc57-4b28-884d-c7734e4c64c1", "name": "l(r:p1rdm103-p1rlv122)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd7286c0-4c57-435f-bed2-fd9a927de8cc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b02739e-d082-4c54-8deb-8ccc83ab82ab"}}}], "length": {"value": 0.0117766, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "80537724-8dad-4e90-9c0f-536cfeb4f9aa", "name": "l(r:p1rdm103-p1rdt48lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f1790fe-a399-46e3-b9e3-5979837777ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd7286c0-4c57-435f-bed2-fd9a927de8cc"}}}], "length": {"value": 0.0197485, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0cac18f1-d0e4-45c0-9221-b52524ca2f6d", "name": "l(r:p1rdt49lv-p1rlv146)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e5bcc7e-f35c-4bbf-a7ff-a82817488b11"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da2538bd-189b-4699-823b-ed459d94b422"}}}], "length": {"value": 0.0323291, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "13eb61ae-13e2-4fcc-a1a7-33a49f742fef", "name": "l(r:p1rdm104-p1rlv82)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2409ced2-7817-40af-951f-33d725e9d75a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3ddd704-2530-4392-8e9e-06e047b12f41"}}}], "length": {"value": 0.018038, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0bf98212-8412-4b8c-8960-9f693eb62909", "name": "l(r:p1rdm104-p1rdt49lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e5bcc7e-f35c-4bbf-a7ff-a82817488b11"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2409ced2-7817-40af-951f-33d725e9d75a"}}}], "length": {"value": 0.0322986, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8527ab91-ca01-4884-958f-9bf6cadfb78d", "name": "l(r:p1rdm105-p1rlv107)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8385921-c183-4c26-bc99-bf5f0364c18b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "096e92a6-ea34-435e-a059-57d5234e1654"}}}], "length": {"value": 0.0143529, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "477a74e8-32b9-4d2f-8c62-4a8e287e6159", "name": "l(r:p1rdm105-p1rdt49lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e5bcc7e-f35c-4bbf-a7ff-a82817488b11"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8385921-c183-4c26-bc99-bf5f0364c18b"}}}], "length": {"value": 0.025904, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "eeb8dff2-6d0f-4edd-ab69-3e388cb798e4", "name": "l(r:p1rdt50lv-p1rlv127)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8208c617-caa9-46a5-b28a-8a5b0d9898a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ae7b1fe-08c4-4848-867e-e2426a325a99"}}}], "length": {"value": 0.0188957, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b4256583-e043-485c-b1d9-d6895fd573e8", "name": "l(r:p1rdm107-p1rlv83)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7948c980-abf7-4357-9ff8-4be9122a3167"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24c3e8d8-1520-4a05-84af-a70da6140b4d"}}}], "length": {"value": 0.02164, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "312ba1b5-d276-4196-b974-e562abef042c", "name": "l(r:p1rdm107-p1rlv123)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7948c980-abf7-4357-9ff8-4be9122a3167"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6184fe8d-ae60-426a-8c0c-a3cc56c5b67e"}}}], "length": {"value": 0.0223678, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ee3cd3d5-6ad3-46f8-be26-c622fe63b8e3", "name": "l(r:p1rdm107-p1rdt50lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8208c617-caa9-46a5-b28a-8a5b0d9898a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7948c980-abf7-4357-9ff8-4be9122a3167"}}}], "length": {"value": 0.01639, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d826c2fb-edda-469a-8669-c708580b5496", "name": "l(r:p1rdm110-p1rlv135)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2deeb6a-3ea7-44d9-9ee0-b013733dadc4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbdefe7a-517b-495b-88b8-dcf15a9429ff"}}}], "length": {"value": 0.0127473, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b029d869-0f98-49a8-ae56-7d0d5762a52f", "name": "l(r:p1rdm110-p1rdt50lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8208c617-caa9-46a5-b28a-8a5b0d9898a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2deeb6a-3ea7-44d9-9ee0-b013733dadc4"}}}], "length": {"value": 0.0164, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "205b7f88-30e3-477c-8222-63e49c3e5d9f", "name": "l(r:p1rdt51lv-p1rlv84)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09d7f030-a9b4-4705-82af-6cf140ba64d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "55e7538f-4bde-4810-a237-ac0cad7ba805"}}}], "length": {"value": 0.0456569, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "239e52d2-6f1c-4541-b593-743f536d2902", "name": "l(r:p1rdt51lv-p1rlv93)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09d7f030-a9b4-4705-82af-6cf140ba64d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0060c029-188f-4725-a935-8d0d9cc892f7"}}}], "length": {"value": 0.0305916, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a60d8329-112d-4656-b827-353773776f11", "name": "l(r:p1rdm113-p1rlv85)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5dd2d9f-42d5-48c4-b1e1-34ae6aa555df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcc52dd9-bacb-4e49-a057-d3747f89a7f7"}}}], "length": {"value": 0.0311927, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "5f3de303-599b-4841-99bd-cbb5d215b96a", "name": "l(r:p1rdm114-p1rlv91)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f42789f3-35c3-4d0d-adda-2044adce92c0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a1f01bc-d1f1-4d92-b1e2-1f8223624c52"}}}], "length": {"value": 0.0125623, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d83ba6fd-6457-4dda-a12d-dd5e09239ede", "name": "l(r:p1rdm113-p1rdm114)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5dd2d9f-42d5-48c4-b1e1-34ae6aa555df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f42789f3-35c3-4d0d-adda-2044adce92c0"}}}], "length": {"value": 0.0299732, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4d3d0323-36de-40d0-8acd-e15ce914b8e3", "name": "l(r:p1rdm113-p1rdt52lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c70a7331-8c41-4370-b053-3eae432d52ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5dd2d9f-42d5-48c4-b1e1-34ae6aa555df"}}}], "length": {"value": 0.0479351, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ebaf4901-4748-4e10-9bb6-f80772e1827b", "name": "l(r:p1rdm115-p1rlv94)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2d46cd2-9caf-47a7-b134-a29fccd91b9c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db2d4080-1f43-47a3-9f3a-e25d1e4f5076"}}}], "length": {"value": 0.0260186, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "55a80fa5-3bf1-418a-ad5c-7afa1fdf1e6c", "name": "l(r:p1rdm115-p1rlv103)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2d46cd2-9caf-47a7-b134-a29fccd91b9c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85afc796-3fe5-4027-b84e-10d502124636"}}}], "length": {"value": 0.0244121, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c44afe7e-8438-4d2c-a1e6-382731061903", "name": "l(r:p1rdm115-p1rlv144)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2d46cd2-9caf-47a7-b134-a29fccd91b9c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b7dbf54-f6bc-4e20-b2f3-8c63a44dd993"}}}], "length": {"value": 0.0176755, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f0aa2a13-e0c6-4712-8ce1-2b96b3454699", "name": "l(r:p1rdm116-p1rlv98)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0d6e82b-cba7-4c7e-8715-d73c3530bad7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "82f19d5c-0941-411d-8baa-3ba029471dae"}}}], "length": {"value": 0.0189352, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b9299fb3-8eb3-4d8c-beab-ef5d8bb3bd1a", "name": "l(r:p1rdm116-p1rlv136)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0d6e82b-cba7-4c7e-8715-d73c3530bad7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b45d086e-8e0d-42f4-a8ec-6d3a9579a96b"}}}], "length": {"value": 0.0258527, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "50eab12d-7e60-4f3e-86f8-77d7b63e1519", "name": "l(r:p1rdm115-p1rdm116)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2d46cd2-9caf-47a7-b134-a29fccd91b9c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0d6e82b-cba7-4c7e-8715-d73c3530bad7"}}}], "length": {"value": 0.012779, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1a90bcc3-121b-46ea-94ea-72690102cce8", "name": "l(r:p1rdm115-p1rdt52lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c70a7331-8c41-4370-b053-3eae432d52ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2d46cd2-9caf-47a7-b134-a29fccd91b9c"}}}], "length": {"value": 0.0312606, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a96a0a61-3593-4283-b799-abda634a973a", "name": "l(r:p1rdm122-p1rlv125)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "329f78a6-af13-4ceb-bc87-4660d497c22e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3367cc2-b096-4cfb-ae71-038eb9e06b46"}}}], "length": {"value": 0.027476800000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6105b98f-5c04-4aaf-8f0c-a630b2e674a6", "name": "l(r:p1rdm122-p1rlv148)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "329f78a6-af13-4ceb-bc87-4660d497c22e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa8af0a4-4d55-41e4-83d1-4fe349920e38"}}}], "length": {"value": 0.0149493, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "34c5ce67-2b3c-449c-a145-88ccef71510b", "name": "l(r:p1rdm121-p1rlv111)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d595142-3854-4152-b64a-6cda8396a523"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66748ae6-b6ef-4228-bb0f-f9a121f0e1a3"}}}], "length": {"value": 0.03370220000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f9ab571c-93e7-490b-be92-60d27d05330f", "name": "l(r:p1rdm123-p1rlv131)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2e27276-ea6c-40a3-92d3-4648ec9d235d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "499fb461-ccb6-436a-8078-eec9beffb4a9"}}}], "length": {"value": 0.0223731, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f08beed6-f030-42b2-b689-6fd6dffe7d03", "name": "l(r:p1rdm121-p1rdm123)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d595142-3854-4152-b64a-6cda8396a523"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2e27276-ea6c-40a3-92d3-4648ec9d235d"}}}], "length": {"value": 0.013548500000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6733f40f-da94-451d-ba9c-afc9bfd279e4", "name": "l(r:p1rdm121-p1rdm122)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "329f78a6-af13-4ceb-bc87-4660d497c22e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d595142-3854-4152-b64a-6cda8396a523"}}}], "length": {"value": 0.0118562, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "50295530-0eb2-46e9-b8d5-a2010ea2855a", "name": "l(r:p1rdm122-p1rdt53lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2536a0eb-a35c-40d4-9773-b78379e7481a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "329f78a6-af13-4ceb-bc87-4660d497c22e"}}}], "length": {"value": 0.0118562, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2688b58c-4fd5-467c-9a5a-8962e7d77466", "name": "l(r:p1rdm124-p1rlv141)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9f62740-f47f-4c97-bae7-4380fe83fcbc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb69a6a9-3eaf-4fc3-82be-0eec77455a82"}}}], "length": {"value": 0.0132542, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f0af7522-e5a1-45b8-a7fa-b575d9c6c63d", "name": "l(r:p1rdm120-p1rlv89)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1071344-55a0-4684-9fbf-5729ec1f21c2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24d75e9a-0249-48ca-ad10-32738bb6a519"}}}], "length": {"value": 0.010837, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c06a98a5-6584-47f6-80ff-d3e030eb948f", "name": "l(r:p1rdm120-p1rdm124)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9f62740-f47f-4c97-bae7-4380fe83fcbc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1071344-55a0-4684-9fbf-5729ec1f21c2"}}}], "length": {"value": 0.0349944, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7714abfb-4610-4b7d-9630-1be09cdc28fb", "name": "l(r:p1rdm124-p1rdt53lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2536a0eb-a35c-40d4-9773-b78379e7481a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9f62740-f47f-4c97-bae7-4380fe83fcbc"}}}], "length": {"value": 0.0174998, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e080f5fa-042f-4074-8eea-968559086793", "name": "l(r:p1rdt54lv-p1rlv90)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57889d14-4aac-4aee-a9e2-677a047e8054"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e06b2ac7-926e-4caf-afac-386910d4ea5e"}}}], "length": {"value": 0.05434540000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2e600f0e-d9b7-4e78-961b-8a6d0b046494", "name": "l(r:p1rdt54lv-p1rlv105)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57889d14-4aac-4aee-a9e2-677a047e8054"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fe82ede-430d-454d-b9d0-e212d0621ea1"}}}], "length": {"value": 0.0270168, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "26085e14-749e-4f2b-a8c0-be910144cf4c", "name": "l(r:p1rdt56lv-p1rlv96)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85ad3bf0-7e82-4e32-8106-faddcf725bdf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31508077-f731-47cb-94a9-869d7910e406"}}}], "length": {"value": 0.0243138, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d926d302-a341-4969-9971-0260425c8bef", "name": "l(r:p1rdm131-p1rlv804)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a60b127d-0530-495e-b3b9-2ebabf070fa1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a11ba246-99d9-4cf5-a557-bec53c75e6fb"}}}], "length": {"value": 0.0159541, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "23ec8047-b4d9-4836-9ad5-57087153b0b5", "name": "l(r:p1rdm131-p1rdt56lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85ad3bf0-7e82-4e32-8106-faddcf725bdf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a60b127d-0530-495e-b3b9-2ebabf070fa1"}}}], "length": {"value": 0.09807820000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3f894fd6-ef69-4853-be69-9ad20f68588d", "name": "l(r:p1rdm133-p1rlv99)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bf5bf18-363d-4f4e-bf10-9ffc601c0f30"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc4a448a-c6cb-4714-b8e6-b75bc6bc219c"}}}], "length": {"value": 0.0124594, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2680f81d-187f-458a-87c9-3e3af28acdaa", "name": "l(r:p1rdm133-p1rdt58lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3367c40-9f47-42d9-b627-bc502b170f2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bf5bf18-363d-4f4e-bf10-9ffc601c0f30"}}}], "length": {"value": 0.0166928, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "79b3a5aa-4572-4e8e-81ec-f62100bf8f85", "name": "l(r:p1rdm134-p1rlv101)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32e76273-c930-4506-9610-8cbfca04af67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48d1be49-5aca-4e18-8b85-2a1274b3f26d"}}}], "length": {"value": 0.027751, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e553c362-e091-4433-818b-930c420bf0a0", "name": "l(r:p1rdm134-p1rdt58lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3367c40-9f47-42d9-b627-bc502b170f2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32e76273-c930-4506-9610-8cbfca04af67"}}}], "length": {"value": 0.0166928, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "aab15890-22e5-493d-8c40-2a9eb3680b9c", "name": "l(r:p1rdm135-p1rlv100)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7b11b31-78f1-41fa-b511-df76daad0efc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62a0d673-eaba-4032-9038-8095e2d53999"}}}], "length": {"value": 0.0216228, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "045e775e-d108-4d2d-bff1-fd70db392191", "name": "l(r:p1rdm135-p1rdt59lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8aca9934-9439-4ce6-9ee3-475980324054"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7b11b31-78f1-41fa-b511-df76daad0efc"}}}], "length": {"value": 0.01639, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "299c7e4a-01dd-4183-8922-cd3a145251f0", "name": "l(r:p1rdm136-p1rlv121)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a415176a-ddab-47a0-9ce7-54c53c4c0f11"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0dbaab50-3abc-4207-82dc-5fcc5be68aad"}}}], "length": {"value": 0.024910800000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "def46ab3-205a-44d1-8334-ca8d8e6177c4", "name": "l(r:p1rdm136-p1rdt59lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8aca9934-9439-4ce6-9ee3-475980324054"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a415176a-ddab-47a0-9ce7-54c53c4c0f11"}}}], "length": {"value": 0.018122, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0a52364f-f121-431c-a2b3-2b5afc7a1064", "name": "l(r:p1rdt60lv-p1rlv102)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2517cea-05d3-4b7f-b9fc-0df0fde81235"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06a432e3-dd37-4c52-b954-6652bb529c8e"}}}], "length": {"value": 0.027151, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "45d4171e-dfd6-4632-a1f4-1631c7bb39fb", "name": "l(r:p1rdm138-p1rlv104)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e53344e0-e328-4acd-b159-e1f8cc246996"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c76c5b8f-1994-470c-a024-b97c73b9bb41"}}}], "length": {"value": 0.024191, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fd16c16e-bcb3-49ac-b2c8-5b3f035f1a47", "name": "l(r:p1rdm138-p1rdt61lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70f11a44-826f-45b8-9dc3-0f51ce6c9733"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e53344e0-e328-4acd-b159-e1f8cc246996"}}}], "length": {"value": 0.031133800000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8f90a935-dde4-4055-911b-e8879ea22ef8", "name": "l(r:p1rdm139-p1rlv124)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "022bda10-6b1a-408b-a231-adb63e189d14"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e5ca78b-6151-4a35-8a04-1bab215f0f10"}}}], "length": {"value": 0.0139389, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ff500abb-a8c2-406e-b3f7-762556f3baf4", "name": "l(r:p1rdm139-p1rdt61lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70f11a44-826f-45b8-9dc3-0f51ce6c9733"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "022bda10-6b1a-408b-a231-adb63e189d14"}}}], "length": {"value": 0.04687960000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "229322ea-6622-4b66-b281-0c2279fd872b", "name": "l(r:p1rdt63lv-p1rlv109)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fac6d4e1-b14d-4973-9626-6a4bde2d2a42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c76fc99c-c160-4ed0-85dd-ec3da962bb24"}}}], "length": {"value": 0.0188407, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "29137b68-38a0-4299-9224-4de2da7e7ec2", "name": "l(r:p1rdt63lv-p1rlv112)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fac6d4e1-b14d-4973-9626-6a4bde2d2a42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25edc94b-a44b-4200-8cde-73941c2818b8"}}}], "length": {"value": 0.04148810000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "90fa423f-c3aa-41a3-b1ff-5e27be2447cf", "name": "l(r:p1rdm143-p1rlv139)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21b14d95-6634-4f0e-a380-d5e57328d825"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b515111-3455-471a-aba8-92c82624a195"}}}], "length": {"value": 0.0108102, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "34f808d1-99d2-4282-862a-0ada3cd93d88", "name": "l(r:p1rdm143-p1rdt63lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fac6d4e1-b14d-4973-9626-6a4bde2d2a42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21b14d95-6634-4f0e-a380-d5e57328d825"}}}], "length": {"value": 0.016739300000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4283d362-7320-4954-872c-29955cf66239", "name": "l(r:p1rdm145-p1rlv113)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09182ca9-8ea2-4d1c-9c3e-5850a77c1b66"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2756378a-0c67-47cf-969d-bdb9e55c8a4b"}}}], "length": {"value": 0.020074400000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "040ec575-fb08-4511-ad29-6f7f2a4d7af6", "name": "l(r:p1rdm145-p1rlv128)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09182ca9-8ea2-4d1c-9c3e-5850a77c1b66"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56bc8935-c658-424c-83d8-0d13bf8d292a"}}}], "length": {"value": 0.0115543, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c1b08193-75f8-4a5a-bf68-d42b893314b1", "name": "l(r:p1rdm145-p1rdt65lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ae9cb89-7cb8-48c6-a5bc-4178ee364ae8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09182ca9-8ea2-4d1c-9c3e-5850a77c1b66"}}}], "length": {"value": 0.0459314, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0091adf2-477d-4aec-bab4-b4f1d4f1e4bd", "name": "l(r:p1rdm147-p1rlv838)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "de7551d6-5168-440c-8fe2-9f17e0904c29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7ffe87d-4424-4495-83c1-6765d385207c"}}}], "length": {"value": 0.0255431, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8d2187a7-f961-459a-84c8-fd146db95437", "name": "l(r:p1rdm147-p1rdt65lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ae9cb89-7cb8-48c6-a5bc-4178ee364ae8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "de7551d6-5168-440c-8fe2-9f17e0904c29"}}}], "length": {"value": 0.0470531, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2ae9cae5-3620-485e-bc07-7fb5feee034e", "name": "l(r:p1rdt66lv-p1rlv114)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfb9fa3b-c758-4c2e-bc51-f297b1ed21bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7934cd3-dcd6-4b67-8206-8a3636b6f75d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "8024cb11-d099-42e8-a763-d30f1bb4a619", "name": "l(r:p1rdt68lv-p1rlv118)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd2d6296-a302-4027-9e5f-c24a56a1a1ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "247e37b3-d6d0-41d7-a6b3-ee29d415da50"}}}], "length": {"value": 0.059931, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "145aef75-cb5e-433d-8d5a-8361f88a52f2", "name": "l(r:p1rdt69lv-p1rlv129)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7057debb-bd4d-4156-a253-0f3a14cdd784"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6c42586-4f46-45c6-910f-90fca771cfd2"}}}], "length": {"value": 0.0182448, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "07a96d7b-4253-4b07-938f-5f40eb0597b4", "name": "l(r:p1rdt69lv-p1rlv140)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7057debb-bd4d-4156-a253-0f3a14cdd784"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47b7d9f8-ca72-4a77-af67-74ee561f7f10"}}}], "length": {"value": 0.0205388, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "326b2815-73fb-47a1-b2b2-e52a6009bae3", "name": "l(r:p1rdt70lv-p1rlv133)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02440066-bc62-4629-96c5-4b497827de5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31dc8280-eb14-4f87-85d7-8eae17013fe7"}}}], "length": {"value": 0.027257900000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0896fb8c-8a94-4a92-8427-e52dd8da6f11", "name": "l(r:p1rdm155-p1rlv134)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43d5d2c5-10f6-4e89-91fa-5186f269b659"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "425bdcfa-9753-4ef5-bb38-9e014ae779dc"}}}], "length": {"value": 0.0117214, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "67b0fa5c-c109-4dc4-a7e5-8a596918e2c5", "name": "l(r:p1rdm155-p1rdt71lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e71f106d-4b41-405f-bce9-3d06b336a554"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43d5d2c5-10f6-4e89-91fa-5186f269b659"}}}], "length": {"value": 0.024182, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "68303935-f043-4a5f-ae67-0cef20dd642e", "name": "l(r:p1rdm156-p1rlv145)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8357e543-eba0-4863-9d95-e34d84a3fae7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1704e67-dfa3-4a6b-a3f4-7ebba9d27537"}}}], "length": {"value": 0.014900100000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bfa069fa-7070-4e5b-b9aa-1521209b1000", "name": "l(r:p1rdm156-p1rdt71lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e71f106d-4b41-405f-bce9-3d06b336a554"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8357e543-eba0-4863-9d95-e34d84a3fae7"}}}], "length": {"value": 0.013317800000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5900d375-7f71-4fe1-a29a-4d36a9287091", "name": "l(r:p1rdt72lv-p1rlv147)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b59eeab-d997-4186-ab59-0424644d5aeb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "070d9a60-c6f2-424c-bd0f-66c52d349f0c"}}}], "length": {"value": 0.021214800000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "35f35705-9799-435b-ae55-94c357a8cb75", "name": "l(r:p1rdm158-p1rlv149)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35f3fd4d-f962-4e4e-89d8-8b41a07ff57d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "063e89ea-6dd0-404f-abfb-21686f3041ed"}}}], "length": {"value": 0.0223159, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "88271973-bd02-47cf-8ce6-9297ca915d33", "name": "l(r:p1rdm158-p1rdt73lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f027d15-df82-4989-93e5-a3b40c862b08"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35f3fd4d-f962-4e4e-89d8-8b41a07ff57d"}}}], "length": {"value": 0.0177535, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "94aed7aa-d694-4d27-ac2a-69f72d010664", "name": "l(r:p1rdm159-p1rlv167)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b8d2667-d52b-46b3-ace4-2ad2b4e3050e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5187e006-621e-4c15-9604-0272ae62887c"}}}], "length": {"value": 0.0172799, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3f4794ef-c7bb-47ed-ae29-ece483a30c44", "name": "l(r:p1rdm159-p1rdt73lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f027d15-df82-4989-93e5-a3b40c862b08"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b8d2667-d52b-46b3-ace4-2ad2b4e3050e"}}}], "length": {"value": 0.0177535, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9a4c7fc8-af6b-46fd-a354-08371ebfcf7e", "name": "l(r:p1rdm160-p1rlv150)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb4a799f-0e03-4ba6-b8ce-8f5e117fd2c2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b9979ec-4e43-4feb-a617-28191e9dd9d8"}}}], "length": {"value": 0.023161300000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d7a1bde2-f7a2-4d8d-8c90-3c65fbc01fba", "name": "l(r:p1rdm160-p1rdt74lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37880102-8a9c-4f7b-930a-b29a94241866"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb4a799f-0e03-4ba6-b8ce-8f5e117fd2c2"}}}], "length": {"value": 0.0168665, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4d2c8db5-28f9-42a7-b24f-191844d2df53", "name": "l(r:p1rdm161-p1rlv169)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "243cdb10-5012-48b5-809f-1952913bf655"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e326756-7ead-4099-a065-9f2de5693197"}}}], "length": {"value": 0.0219801, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "dfdccb19-3918-4a66-8ff9-42e75bc5e315", "name": "l(r:p1rdm161-p1rdt74lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37880102-8a9c-4f7b-930a-b29a94241866"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "243cdb10-5012-48b5-809f-1952913bf655"}}}], "length": {"value": 0.0168563, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "94875e3d-2424-4911-a398-14b27da184b9", "name": "l(r:p1rdt75lv-p1rlv151)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "699bbf24-59ba-4dba-8bd4-1cf04a7e6e47"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "345b5c48-cd35-418e-bc08-50c06f5dff09"}}}], "length": {"value": 0.0195504, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a9a39282-bd02-4e82-ad57-8abf21c4bad6", "name": "l(r:p1rdt76lv-p1rlv154)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ecf2223-f120-45b4-8aab-a36d60161aec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ccdfbc7-d3a6-4f74-ad32-25ff11a2e3b7"}}}], "length": {"value": 0.013038, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "84f9badb-2feb-4fc0-9f7b-2e8a011fde0b", "name": "l(r:p1rdm163-p1rlv153)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0bd295ef-2c38-4c6b-915a-73900e920b92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ebbe09dd-7560-4eff-9e32-803f14b4ce7c"}}}], "length": {"value": 0.0190604, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9844c82d-1619-481b-9355-a508b593d8f2", "name": "l(r:p1rdm163-p1rdt76lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ecf2223-f120-45b4-8aab-a36d60161aec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0bd295ef-2c38-4c6b-915a-73900e920b92"}}}], "length": {"value": 0.0157338, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "79b6b890-dc64-4ae0-82bd-de9ffbe2e0de", "name": "l(r:p1rdt77lv-p1rlv155)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3fd9bf7-ecdd-4dcb-966a-f426d5f2ee81"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2452d5af-5aba-4d4b-8cd9-27a95fe6b34d"}}}], "length": {"value": 0.023128200000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "98981286-258e-4c7d-9452-c6c98e2b96a6", "name": "l(r:p1rdm166-p1rlv156)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e110db24-1653-41b5-8496-821dfff05769"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f607e6b-9540-4845-9f0c-6c334eb0e807"}}}], "length": {"value": 0.0182012, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8f778f87-7e35-45ec-984f-a71d2d2552a6", "name": "l(r:p1rdm166-p1rdt78lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f0255b7-5369-40eb-8814-959b0d4245b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e110db24-1653-41b5-8496-821dfff05769"}}}], "length": {"value": 0.0187893, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "29265848-23e0-4b5f-bc67-c3a69b4ec89d", "name": "l(r:p1rdm167-p1rlv159)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c108a0c2-3093-4222-9547-5ac08f6d8a4a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0ae6c02-c29e-4bf9-b1d4-ecc7e37e7de2"}}}], "length": {"value": 0.0190142, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "70765cfe-bcf3-4651-aef0-ba765d84ad6a", "name": "l(r:p1rdm167-p1rdt78lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f0255b7-5369-40eb-8814-959b0d4245b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c108a0c2-3093-4222-9547-5ac08f6d8a4a"}}}], "length": {"value": 0.0238255, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "169b1bc9-8c2a-45ba-8108-75b0f300554e", "name": "l(r:p1rdt79lv-p1rlv164)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "624d03d5-ac53-4d58-ac86-62834fa13c61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61460072-bdc5-4a70-96fa-8ecfa71623f4"}}}], "length": {"value": 0.0140409, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "289216e0-4528-483f-acbb-e2f23d34c2c3", "name": "l(r:p1rdm168-p1rlv157)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "937989ee-4525-4394-b04f-37d77a2c910c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4355a473-4643-4f72-afe8-80ce773ca8e8"}}}], "length": {"value": 0.030818, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9f6477d9-5d1d-40fe-bb83-7e5a13092058", "name": "l(r:p1rdm168-p1rdt79lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "624d03d5-ac53-4d58-ac86-62834fa13c61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "937989ee-4525-4394-b04f-37d77a2c910c"}}}], "length": {"value": 0.012795000000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bb55e3ed-4ff8-4c38-8295-e3849dbb9b29", "name": "l(r:p1rdt80lv-p1rlv158)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ce05c72-facf-447f-ba14-cc2ef64579a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1cd7284-17fb-4382-a29d-dd8c5bfd7541"}}}], "length": {"value": 0.020056, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "09956226-9e3a-4f6d-9b35-faa0073f0f10", "name": "l(r:p1rdt81lv-p1rlv160)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b610625-09e3-4b72-a8fe-b0c36f5e137c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd2fae5a-e5dd-4ad4-8acc-422de00ae83e"}}}], "length": {"value": 0.0130169, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3eead181-f910-4fda-a540-6d31c233bba1", "name": "l(r:p1rdm172-p1rlv161)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2dad274-0d92-42fa-bf1e-a22af034211f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4842819e-3f17-47da-a8bf-c3402c3c00b7"}}}], "length": {"value": 0.0198598, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9f5ed50e-7216-4609-8db5-2605f3480b51", "name": "l(r:p1rdm172-p1rdt82lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9872669f-fd85-458a-8951-ec12965fb42b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2dad274-0d92-42fa-bf1e-a22af034211f"}}}], "length": {"value": 0.0233983, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0c3c8219-32ba-4305-986d-9d50b230171f", "name": "l(r:p1rdm173-p1rlv830)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44bdfec0-2d44-442d-b562-ac786c61a76a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b7538477-32ab-4db6-872d-83be7ec89fd9"}}}], "length": {"value": 0.016941, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2e07e867-c355-4586-876e-f4e62cece9b3", "name": "l(r:p1rdm173-p1rdt82lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9872669f-fd85-458a-8951-ec12965fb42b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44bdfec0-2d44-442d-b562-ac786c61a76a"}}}], "length": {"value": 0.0146175, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fb158784-8660-4b98-bebd-f836c1d4238d", "name": "l(r:p1rdt83lv-p1rlv163)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8dac1e07-5eb6-4945-a3d9-95b77310358d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "471bad88-4514-4b02-aa1a-1d2aaa15557f"}}}], "length": {"value": 0.021129600000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "92015457-1970-4062-ad0b-862739545707", "name": "l(r:p1rdm175-p1rlv165)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9de64e4-b140-4526-af3c-1f7ceaa687bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e7880c9-0932-4395-abf9-2274e400f280"}}}], "length": {"value": 0.0440542, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6b3be467-1489-413f-8884-dffbbb55fcb7", "name": "l(r:p1rdm175-p1rdt84lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdb8aaf1-0e21-42e0-a72d-666646561235"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9de64e4-b140-4526-af3c-1f7ceaa687bf"}}}], "length": {"value": 0.0128709, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "476a440b-2b65-427e-9160-56b6f9589207", "name": "l(r:p1rdm176-p1rlv166)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a6bf0b9-809d-48fb-b8bd-375df052b6cc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21d333f7-7426-4fa6-8ab2-c6118055ece1"}}}], "length": {"value": 0.0268124, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "77c0c35b-8ab2-45bb-9665-5cfb22ed9809", "name": "l(r:p1rdm176-p1rdt84lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdb8aaf1-0e21-42e0-a72d-666646561235"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a6bf0b9-809d-48fb-b8bd-375df052b6cc"}}}], "length": {"value": 0.014891, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a0cb5616-3b4a-4ef2-a418-0f34f92e5cde", "name": "l(r:p1rdt85lv-p1rlv168)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40f4034e-c735-419b-80cd-d729d75f4692"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "470fe3ed-5b24-438a-ba6d-cdd9f774e5ad"}}}], "length": {"value": 0.0181757, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "60e2ab6d-9475-4352-8dff-e83ebfd55fd3", "name": "l(r:p1rdt89lv-p1rlv174)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1186295-59ff-48a8-b31d-0f7cd40df1ab"}}}], "length": {"value": 0.059378900000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b34af2ca-a059-4e01-93f4-75562afe5d6a", "name": "l(r:p1rdt89lv-p1rlv175)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905e9287-bdb6-44e0-b0af-f59ab4ad4d8e"}}}], "length": {"value": 0.0220486, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7a00cf1f-e224-44c2-b130-ae181cbc684b", "name": "l(r:p1rdt89lv-p1rlv176)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "931c8cee-89fe-447d-8788-af1e5f9f8775"}}}], "length": {"value": 0.0331252, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "5cbc1082-febb-4953-b261-752d2c159e74", "name": "l(r:p1rdt89lv-p1rlv177)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "090d6084-5cc6-473d-99c0-a6309571d633"}}}], "length": {"value": 0.053761, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b428ecd9-3158-4565-9fd1-6e401d34c594", "name": "l(r:p1rdt89lv-p1rlv178)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9debf70-62f4-4870-ad8b-bffc4bc4ad3f"}}}], "length": {"value": 0.0259912, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "81c89f55-1e6d-495b-a730-bfcacf30aafe", "name": "l(r:p1rdt89lv-p1rlv179)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb03260b-d7d7-4779-ab2c-37c9a1e34d66"}}}], "length": {"value": 0.0485967, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0f9cbb19-2251-459a-8fef-5974f0e19e65", "name": "l(r:p1rdt150lv-p1rlv285)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d156fdde-5620-4a6f-b8c1-a3ab986fcc88"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d3a86df-2ac5-4959-b857-562795ce84ba"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "a7fc4ccd-23ad-4d23-9c5d-01f39107d778", "name": "l(r:p1rdt177lv-p1rlv337)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d64d858-a9f7-430f-890e-a456f8913c30"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57b88281-b728-4779-82b1-4cc9eb4b41b1"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "6fe53808-07ef-4c59-8888-4ecf921fbd4a", "name": "l(r:p1rdt178lv-p1rlv338)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3314fa8-a838-4028-abb5-043425fd0785"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6b2aba6-a289-4a50-a131-2064047d1341"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "c2486b9c-458d-4c7d-a30b-2005a6509c49", "name": "l(r:p1rdt180lv-p1rlv340)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3e633bc-311e-4698-a413-9c6cf09c42a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb4797d6-b46e-4058-8985-d9f4b660f0a7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "bd6ee48d-28b5-4315-aa01-18786c9521fd", "name": "l(r:p1rdt181lv-p1rlv341)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05401825-91f8-41f8-9204-ab5806458594"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54f0ea2c-3849-4ff0-ad8c-e3f65515d178"}}}], "length": {"value": 0.0184707, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1b31f96a-78eb-4c21-a342-8e9911075c8f", "name": "l(r:p1rdt181lv-p1rlv342)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05401825-91f8-41f8-9204-ab5806458594"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13754fdb-4039-49fb-b584-8437191dfb2b"}}}], "length": {"value": 0.0184707, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6268230d-7e2d-460a-a71c-f4728aeb6115", "name": "l(r:p1rdt182lv-p1rlv343)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db407ddd-fb81-4767-99e1-9aeab12fc770"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0197ef22-9f8f-48a9-84de-663a7ce22773"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b1a02585-8b94-4e80-b57f-1077bfeba63f", "name": "l(r:p1rdt209lv-p1rlv377)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4724ea16-dc31-48f8-98b8-b9a223e9a4bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e1ea241-5329-4db5-996a-df09a9c25687"}}}], "length": {"value": 0.0107399, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "956ab7d4-2958-436c-a13d-ffd2364dc552", "name": "l(r:p1rdt209lv-p1rlv379)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4724ea16-dc31-48f8-98b8-b9a223e9a4bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50225dcf-40bc-44b5-9dec-072ac5b2334e"}}}], "length": {"value": 0.0107399, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2f7cb6af-5e60-46b7-9658-4724b60445a0", "name": "l(r:p1rdt210lv-p1rlv378)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05f6a3bf-d465-4f16-8205-616d1f4dd465"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3ff63a0-bf3f-43b0-807c-935467b4fe46"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "cf7a4cd4-9ab0-4b90-838b-e3dc4f53c107", "name": "l(r:p1rdt211lv-p1rlv380)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1d5af6ce-9a4c-414a-bbd8-15d82f50cb57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ee07ef9-b7b0-4457-be1c-78e754dbcfc7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "d5ffdfd7-04b1-491f-96ab-1d221c5a2721", "name": "l(r:p1rdt233lv-p1rlv415)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "591461d4-20da-4165-a210-4dbaedd81016"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b54aae8-5a94-4e04-882f-748e1c5f1390"}}}], "length": {"value": 0.0211272, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0505f748-32fd-40ee-adcc-f8ae4f7aa5e0", "name": "l(r:p1rdt233lv-p1rlv416)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "591461d4-20da-4165-a210-4dbaedd81016"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99abc7dc-8e15-420f-9bc9-0e6229d4dab3"}}}], "length": {"value": 0.0170787, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3e94a0ef-755f-4c61-8339-9228a6a9a348", "name": "l(r:p1rdm434-p1rlv412)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "019c88af-413c-4331-84f7-923a1df0a303"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b33ed36-116b-4741-9374-6927bd537427"}}}], "length": {"value": 0.0284617, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c321be1c-7377-4681-bef4-1a0174a2eae3", "name": "l(r:p1rdm434-p1rdt233lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "591461d4-20da-4165-a210-4dbaedd81016"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "019c88af-413c-4331-84f7-923a1df0a303"}}}], "length": {"value": 0.0343908, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6be33d65-8fea-460c-a84a-a0e3f510cfd2", "name": "l(r:p1rdm437-p1rlv419)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3b3eb51-c011-4f2c-8a10-c43c9c86217b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7935b9c-b631-432c-a322-9beea73f1fc4"}}}], "length": {"value": 0.0215859, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "98182c6b-dfb8-473b-8d57-952c06f1388d", "name": "l(r:p1rdm438-p1rlv420)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a713d96-e13f-447e-ab9f-012af3e26afe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4d7ed8-5ddd-4127-87ab-eb3f48a580c2"}}}], "length": {"value": 0.0147074, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "befe0c14-01c2-4b06-a7f9-2a47fc69e8cb", "name": "l(r:p1rdm437-p1rdm438)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3b3eb51-c011-4f2c-8a10-c43c9c86217b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a713d96-e13f-447e-ab9f-012af3e26afe"}}}], "length": {"value": 0.0117282, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "578c6339-ef3b-4716-adb1-a9e5b3ed6b05", "name": "l(r:p1rdm437-p1rdt233lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "591461d4-20da-4165-a210-4dbaedd81016"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3b3eb51-c011-4f2c-8a10-c43c9c86217b"}}}], "length": {"value": 0.0343908, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "42624629-eac1-4745-adf2-53d1be42e2d3", "name": "l(r:p1rdm439-p1rlv413)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "adb2d039-e162-43f7-8498-1374581a75fc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8408ac87-a086-46bc-9d88-cca79e17dd62"}}}], "length": {"value": 0.015615700000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5b4cc8dc-fc2d-4cb2-a6bd-7786ab4a81a2", "name": "l(r:p1rdm439-p1rdt234lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e480f304-b192-4107-91e1-131d481657b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "adb2d039-e162-43f7-8498-1374581a75fc"}}}], "length": {"value": 0.0177624, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e091d378-1707-46e2-9007-81ca0fb1783d", "name": "l(r:p1rdm440-p1rlv417)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84570b2e-efeb-477e-be1c-43b9d2922fda"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49dbdd44-a36a-46b5-aef8-558ef7693315"}}}], "length": {"value": 0.0243364, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "808b2de4-c291-4a98-bf76-253fbf95aa27", "name": "l(r:p1rdm440-p1rdt234lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e480f304-b192-4107-91e1-131d481657b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84570b2e-efeb-477e-be1c-43b9d2922fda"}}}], "length": {"value": 0.0354523, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f7407667-b6d5-4229-a8a0-b06a8bc055e6", "name": "l(r:p1rdt235lv-p1rlv421)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d8a6708a-d098-4e02-aac6-4aba7fdc71a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12dcb168-1bfe-448b-8d9a-f5cb4c61aafe"}}}], "length": {"value": 0.015099000000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8b295164-05a6-4f11-95bb-179fa6784c17", "name": "l(r:p1rdt236lv-p1rlv422)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7dd709e3-c5ec-4a01-8297-11f4d1261c3a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa7bb51b-8ba8-4a05-872a-7f5ce084fe88"}}}], "length": {"value": 0.0221266, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8526a0f0-81c9-4b1e-b0fd-6ca440c0c355", "name": "l(r:p1rdt236lv-p1rlv423)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7dd709e3-c5ec-4a01-8297-11f4d1261c3a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c1e9680-f7de-497c-953a-54f4db2899e2"}}}], "length": {"value": 0.013832, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "85e410b3-3fd8-4adf-b912-606c69de0cc1", "name": "l(r:p1rdt237lv-p1rlv424)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b72726f3-250c-4d98-86bc-5120137bd0f1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1a91c8c-aabd-4fad-8306-908f186a5744"}}}], "length": {"value": 0.0173984, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "63a6ee4f-9a39-4d73-94c7-2011f40c3e2a", "name": "l(r:p1rdt237lv-p1rlv449)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b72726f3-250c-4d98-86bc-5120137bd0f1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "753035df-8705-48eb-92b3-c4bef603b66b"}}}], "length": {"value": 0.0173984, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7090fbe2-cb8c-4c09-b6fa-da9414b54b2b", "name": "l(r:p1rdt251lv-p1rlv439)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42dff28c-89e7-4b56-bf23-3dcdd3ca216f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f771660-4dad-43df-b38b-7da5f6180a25"}}}], "length": {"value": 0.0641388, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d8826333-a219-4797-a8d9-92cd616ce986", "name": "l(r:p1rdt251lv-p1rlv445)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42dff28c-89e7-4b56-bf23-3dcdd3ca216f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d665758-71e1-4478-b39d-671f78f623e5"}}}], "length": {"value": 0.05250030000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f668b2d1-629e-440a-bc89-69bb83227759", "name": "l(r:p1rdt251lv-p1rlv446)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42dff28c-89e7-4b56-bf23-3dcdd3ca216f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acce3105-f519-491c-921a-df1294795742"}}}], "length": {"value": 0.0829969, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "bba4004f-1129-4d09-95ca-69a606870bc4", "name": "l(r:p1rdt251lv-p1rlv447)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42dff28c-89e7-4b56-bf23-3dcdd3ca216f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "042873fa-10df-4de0-a040-ac429b8bf7d9"}}}], "length": {"value": 0.0834464, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3ec5458c-b354-433b-a8d4-78268d281508", "name": "l(r:p1rdt251lv-p1rlv448)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42dff28c-89e7-4b56-bf23-3dcdd3ca216f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bb83d65-630d-4f1d-8e3d-8937a5a05524"}}}], "length": {"value": 0.0573344, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ad0a49de-fc5d-4d28-b860-b1a01394e3bc", "name": "l(r:p1rdt253lv-p1rlv441)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "704fece3-3b83-4c0b-bcd1-d463b3cdaf6b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a778b00-482c-4b81-8213-f17202a105fa"}}}], "length": {"value": 0.0393745, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e5b3ae7c-65ec-457c-83b8-b09122a326b0", "name": "l(r:p1rdt253lv-p1rlv444)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "704fece3-3b83-4c0b-bcd1-d463b3cdaf6b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30f29674-3083-4da2-95e2-a1f11a7eb7f8"}}}], "length": {"value": 0.0393745, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "66809432-ac15-4760-9231-6d4f6bfb9cf9", "name": "l(r:p1rdt254lv-p1rlv442)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "655d8f44-aa2f-4548-a1ca-83fcce9fa7aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cd667a9-c0ef-49ce-b6ee-7e474d9ae761"}}}], "length": {"value": 0.0182025, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "51d246f9-90d4-4835-bc50-b80c39ceacd0", "name": "l(r:p1rdt254lv-p1rlv443)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "655d8f44-aa2f-4548-a1ca-83fcce9fa7aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2100c17-c0e6-47e9-87f8-72016b22dd4b"}}}], "length": {"value": 0.0182025, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d0823786-024b-4ce4-a47b-e9ad39c63732", "name": "l(r:p1rdt257lv-p1rlv452)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4c28500-44f7-47c6-b8a8-d1e3468494e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb46f1ae-0cdb-45d1-b389-639cdf345f8e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "f289f501-a893-432d-90a7-87d93c77ec10", "name": "l(r:p1rdt258lv-p1rlv453)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad9ffaef-f21b-43da-9f67-3a8271edb6bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6a8a3c7-5165-48b7-8233-30d3af045442"}}}], "length": {"value": 0.0230491, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5c20bbe4-9be1-430f-95f9-596fa613a6e9", "name": "l(r:p1rdt258lv-p1rlv456)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad9ffaef-f21b-43da-9f67-3a8271edb6bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85f0d94e-c096-4d53-ae05-f0dc59f73d02"}}}], "length": {"value": 0.0595648, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0246e7a2-f298-4214-816f-1f9560d5c268", "name": "l(r:p1rdt258lv-p1rlv460)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad9ffaef-f21b-43da-9f67-3a8271edb6bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76b212f9-2e27-4064-a2c5-079786afb1d1"}}}], "length": {"value": 0.0369882, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "647e9cbe-c03f-424e-a989-fff636f9df75", "name": "l(r:p1rdt259lv-p1rlv454)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6a0feb3-78c1-4d69-8d18-2a8c3abdcf54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3493b0ed-43a2-4602-a7ad-a817331c9d8e"}}}], "length": {"value": 0.007000180000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b2c6818b-63e4-4176-97f7-3725e51b766d", "name": "l(r:p1rdt259lv-p1rlv455)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6a0feb3-78c1-4d69-8d18-2a8c3abdcf54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "552153cc-f5be-42ee-9985-9361c2e7e2a1"}}}], "length": {"value": 0.007000180000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "802e828a-0585-47a2-b9f3-0de5df57c988", "name": "l(r:p1rdt260lv-p1rlv458)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d8d796d8-6750-4ca5-ae07-1b07331ce6ee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec66e302-748d-4300-ba65-719de0a906bb"}}}], "length": {"value": 0.0434176, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "46c807d5-43c5-4672-a3dd-a19e5d31c13a", "name": "l(r:p1rdt260lv-p1rlv461)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d8d796d8-6750-4ca5-ae07-1b07331ce6ee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76dd0f1b-4109-4707-a547-f0ab1b6e148f"}}}], "length": {"value": 0.092428, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "79a59573-c06e-4a75-b3f8-53d31d0db6c5", "name": "l(r:p1rdt261lv-p1rlv459)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fe4ec5b6-61fb-4b66-9e43-19d81af88966"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c112196-bcbc-41bc-99a9-f3657c335c7a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "33cd8402-3871-4cca-bc3e-debcfdedae9b", "name": "l(r:p1rdt262lv-p1rlv462)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30952601-1479-4770-9b77-9fe3465310b7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9176da24-7eb5-4b0b-99dd-886c3f974798"}}}], "length": {"value": 0.00892698, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c4e43b97-aaab-467e-ad1b-42d7037f358b", "name": "l(r:p1rdt262lv-p1rlv464)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30952601-1479-4770-9b77-9fe3465310b7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "895d0235-3ee6-4f06-9978-9d615d721ebd"}}}], "length": {"value": 0.00892698, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a2576b3e-d1e5-4d50-a45e-1bc57c336d52", "name": "l(r:p1rdt263lv-p1rlv463)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c7501f4-0394-4766-a3c5-b17fda7f3817"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff9d9cca-1878-478d-a190-b58c9098f13e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "ccb77c32-f2aa-4914-bb43-9d5e74ae182b", "name": "l(r:p1rdt270lv-p1rlv474)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d33a03d6-fddc-4e47-8018-cd7d290b30b0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e589527-d388-4364-87d2-2f4af1a14509"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "31239fc0-0cf9-4784-9c31-840b76d2fb9d", "name": "l(r:p1rdt275lv-p1rlv480)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6715c6a-6869-412a-8e59-e5c2eb03c56b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb55ec0b-b6f7-48a7-8dae-dda95fc34499"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "8efe139e-f094-4b94-bbd7-6baf1eb8bb49", "name": "l(r:p1rdt276lv-p1rlv481)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b478b4f8-8d5e-47b0-a56a-8b991dc8d944"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d9e77ad-42c6-4413-96e6-debfed3c442a"}}}], "length": {"value": 0.0246686, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3108cca4-7ce2-4e79-91c3-6164c8569336", "name": "l(r:p1rdt277lv-p1rlv482)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24486e15-ff1e-45b3-aa02-703263f04844"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d4b708f-cc15-4ee3-87e0-4d26fec02f1e"}}}], "length": {"value": 0.0705132, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "924709b2-b4ce-4ebf-aef2-ea121372a161", "name": "l(r:p1rdt278lv-p1rlv483)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8af5824-d5d7-4cba-98b7-d72993909f22"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d059a618-6f09-404b-b1a0-0e7aa0c55c45"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "7ed80917-269f-463c-95a8-142aa98b6c52", "name": "l(r:p1rdm508-p1rlv484)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d6856ee-d113-45ec-99e0-8a915a89a56c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fde62b60-c5f6-44d6-b2f2-211c21b02033"}}}], "length": {"value": 0.0863808, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "dc284c67-9c82-4d92-ba75-22c40eb1286b", "name": "l(r:p1rdm508-p1rdt279lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bf679fe-712f-4db6-9df9-debb29b7ee73"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d6856ee-d113-45ec-99e0-8a915a89a56c"}}}], "length": {"value": 0.0129614, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "060491fd-0236-4f17-87f0-4f05976cbc99", "name": "l(r:p1rdm509-p1rlv485)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c3bf9bd-d12a-47d7-b2e2-3f31f3a0419b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d2c379-7e19-46c4-8c6e-533fa9db7764"}}}], "length": {"value": 0.0942097, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "39ff8538-f941-481e-9b42-22bd4064b712", "name": "l(r:p1rdm509-p1rdt279lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bf679fe-712f-4db6-9df9-debb29b7ee73"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c3bf9bd-d12a-47d7-b2e2-3f31f3a0419b"}}}], "length": {"value": 0.0129614, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9f41c3d1-c279-430b-97c6-bf785447f250", "name": "l(r:p1rdt280lv-p1rlv486)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e4eafd2-0f68-4e2a-a62c-89cb877004d4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a54b2228-9e7d-4e6b-939d-ab2765454522"}}}], "length": {"value": 0.0500266, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "23cca4ef-3f22-42e7-8a89-81df492f80d6", "name": "l(r:p1rdt281lv-p1rlv487)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e01a56d-1bfc-4169-9c3e-1373f9dbeb38"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2d5799-907e-46fd-a389-120aea352775"}}}], "length": {"value": 0.0588997, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9e629ff1-629c-4692-b1b2-89b36d3232b8", "name": "l(r:p1rdt281lv-p1rlv523)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e01a56d-1bfc-4169-9c3e-1373f9dbeb38"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97c38794-7c60-4ff8-b09b-7503c9604409"}}}], "length": {"value": 0.0588997, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f9183960-d27e-48f4-ae96-51a4370514fa", "name": "l(r:p1rdt297lv-p1rlv524)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a8430e1-656f-4fe2-a11b-00adf429d75d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bef074be-aac4-4d82-a832-641729756802"}}}], "length": {"value": 0.0214257, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "67082ac6-4033-43de-8e8e-060172e68525", "name": "l(r:p1rdt297lv-p1rlv526)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a8430e1-656f-4fe2-a11b-00adf429d75d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ab8e220-faf9-4108-80f8-22d2fe326c3d"}}}], "length": {"value": 0.0214257, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "84650700-4442-4d15-838e-e27a38df0870", "name": "l(r:p1rdt298lv-p1rlv525)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33e93250-9c11-4650-9469-412129855857"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a42f8b99-82c6-4c90-81ea-6ccb38eacfab"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "7b449da2-8e87-4ccd-9f7a-16c7fec58d1b", "name": "l(r:p1rdt303lv-p1rlv531)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6353ab92-f66f-47d8-97ac-058cf030ff82"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32a1d9d7-31c7-4def-88d4-e4d41bd21572"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "e0344bf6-1f0f-4397-9dfd-b63e20f8de7e", "name": "l(r:p1rdt304lv-p1rlv532)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a22ac71-bf3a-4016-86ce-fb25f471be5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1362feeb-2e2c-4dd1-9f49-239c952c6120"}}}], "length": {"value": 0.00939374, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a06c0184-9460-4a48-a932-28ad6fdc65df", "name": "l(r:p1rdt304lv-p1rlv533)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a22ac71-bf3a-4016-86ce-fb25f471be5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f79bc5f-375f-4ecd-b828-eb7b137d7cab"}}}], "length": {"value": 0.00939374, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8ba5afa0-cb40-49c4-9876-5b535d676651", "name": "l(r:p1rdt305lv-p1rlv534)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90948977-fe1a-43b3-a8a4-86c080ae4906"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0eb7074c-0745-4089-9329-aa3495f9b460"}}}], "length": {"value": 0.0332146, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "59645c30-0818-4298-96b3-c2e407a38c87", "name": "l(r:p1rdt305lv-p1rlv535)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90948977-fe1a-43b3-a8a4-86c080ae4906"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9cc91945-564c-4ace-bb53-77150b107b41"}}}], "length": {"value": 0.0280899, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f0cacb07-6f88-4b14-83a4-b12237b908e0", "name": "l(r:p1rdt305lv-p1rlv536)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90948977-fe1a-43b3-a8a4-86c080ae4906"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2ea78a8-b9c5-4760-b153-51b45565069e"}}}], "length": {"value": 0.0133525, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cce21752-5938-47bf-94e3-7a78fc6ba8c6", "name": "l(r:p1rdt306lv-p1rlv537)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53eba878-66fa-4d30-8af4-1f583abe5f16"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9f2dfc9e-0b72-4465-b46a-d4e2a7a08f64"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "7f8caa28-d1d5-4677-b1a8-caeaa8438cd5", "name": "l(r:p1rdt335lv-p1rlv588)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8e448ea-e66d-4e16-80c0-8e742d7cac55"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75628d41-a82d-4425-8aa2-9f377c771a4c"}}}], "length": {"value": 0.0252117, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a90371fa-16c1-4478-aa97-5e4dcfe53c31", "name": "l(r:p1rdt335lv-p1rlv589)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8e448ea-e66d-4e16-80c0-8e742d7cac55"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a1c60be-f1a1-48d6-b396-4cca6d8c4e62"}}}], "length": {"value": 0.0305453, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d3cd2429-6120-47a3-8205-e4b92179c8d4", "name": "l(r:p1rdt335lv-p1rlv590)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8e448ea-e66d-4e16-80c0-8e742d7cac55"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81ce208e-7244-418a-9867-b55b95ba0716"}}}], "length": {"value": 0.0192501, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8e534474-8d24-44b0-9a73-58eba8f2be88", "name": "l(r:p1rdt374lv-p1rlv657)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35993388-185f-4d1d-9dcb-16eb7556728f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e58890e-e6ce-4dda-91c0-5ccfdb5c420d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "d9844c82-b169-457d-9bc1-326623b23d77", "name": "l(r:p1rdt376lv-p1rlv660)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d354e81e-b007-4bbe-b1db-50d7afacd0e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15751ee2-6783-472f-ad57-ec978234fec4"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b54298a1-451c-4e04-b0a2-2a3ce8e8d748", "name": "l(r:p1rdt383lv-p1rlv672)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8569c197-174f-46ef-96c2-e0c674d7b046"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb25bf05-ce7f-405a-8c17-fd166748f7d3"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "6b21aab7-acec-4cf4-ad90-947d2d65d55b", "name": "l(r:p1rdt384lv-p1rlv673)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c56b4839-f007-4c9b-93a7-9147399f983f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31d3267c-7020-4660-9a0b-49cd9d94a5d0"}}}], "length": {"value": 0.0823342, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "05b78e9e-8d95-4a3a-8417-ca2d7471d413", "name": "l(r:p1rdt385lv-p1rlv674)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "579c3e97-d1dc-4306-91e6-4cbbed29f882"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "449992d6-a91b-40ea-9792-5166a5f2c849"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "13c5de65-ecbe-46fc-b13c-9b0ae93f362d", "name": "l(r:p1rdt414lv-p1rlv716)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29a78735-964b-4381-bea0-01e5b1b79be9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "93069f0f-fce7-47cd-b7b3-77e861f59573"}}}], "length": {"value": 0.0271185, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7aa72c83-7926-479e-9241-1847dffc0378", "name": "l(r:p1rdt414lv-p1rlv726)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29a78735-964b-4381-bea0-01e5b1b79be9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fdcbc55-681f-4fe5-8142-4945b25f6fef"}}}], "length": {"value": 0.0271185, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f433fa72-7ae0-4813-aec1-c749feeef425", "name": "l(r:p1rdt415lv-p1rlv717)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "789d55de-619d-43cd-b056-ebe1be4c2dea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd8fd159-f747-4ee4-a426-787f4eef4b42"}}}], "length": {"value": 0.0174256, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "40648953-ee06-4844-ac24-ebe40af874cb", "name": "l(r:p1rdt415lv-p1rlv724)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "789d55de-619d-43cd-b056-ebe1be4c2dea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3658479-7369-4bd9-be54-e7768c93a808"}}}], "length": {"value": 0.0174256, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "38efc7d5-3134-4ecb-a601-e7bab591df93", "name": "l(r:p1rdt416lv-p1rlv718)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473f5822-3412-4f3d-836e-f62314efa5b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4a1453b-98a3-4c2d-8ac2-c8b2ab1bfa4f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "42acdb9f-2a40-47c7-9aba-003a71207202", "name": "l(r:p1rdt417lv-p1rlv719)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98bb09be-6506-49e8-8fd8-1a01d6861162"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3153167-8b4c-40e4-abb7-3bdef86950c3"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "a06652f1-5337-439b-bde4-2b0916c1d9af", "name": "l(r:p1rdt418lv-p1rlv720)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e189aaf-7650-49b4-83dd-94a29111aca2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdbc11b7-5abf-4ff8-8d26-53faf4b1f3f5"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "c090ab4d-ac69-4ffb-8288-8e0f550fad74", "name": "l(r:p1rdt419lv-p1rlv721)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d9603d6-5e5e-4cc0-aa86-1bdb80f7e1cf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf12b67c-4df5-4dcb-a2e2-6ae2d0f82e65"}}}], "length": {"value": 0.08840930000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c9d83670-5d7e-4b3e-907b-e3d7877eccf2", "name": "l(r:p1rdt419lv-p1rlv723)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d9603d6-5e5e-4cc0-aa86-1bdb80f7e1cf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7551be44-a4ca-4edb-b823-6495d163201e"}}}], "length": {"value": 0.0583611, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e16c8db8-7dcb-4a01-9073-23a5a1d29c5f", "name": "l(r:p1rdt419lv-p1rlv725)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d9603d6-5e5e-4cc0-aa86-1bdb80f7e1cf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2bcbabc-a7fc-4230-8ec1-b6050af9cf58"}}}], "length": {"value": 0.0308381, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b986d57f-f8a8-4cd7-a6ec-334c76f99e58", "name": "l(r:p1rdt420lv-p1rlv722)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51673983-9230-421b-8501-bf71601b1b13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b7c6c65-e18c-4e79-b419-8894deb0d345"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "270edca9-1e67-412f-8e69-5ffb1e583c7d", "name": "l(r:p1rdt438lv-p1rlv749)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41f19802-32ca-4afc-8418-fe93e3ced1bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80983704-a98f-46dc-a09f-700bd7df1a29"}}}], "length": {"value": 0.0289764, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "538e127f-786f-4818-89c8-a58995828ae0", "name": "l(r:p1rdt438lv-p1rlv756)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41f19802-32ca-4afc-8418-fe93e3ced1bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3c3b0fb-5a5d-439e-a350-b97ba0df41a0"}}}], "length": {"value": 0.0289764, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f81dbe0e-d0d1-46b8-be6d-f9a7a1fc6ef9", "name": "l(r:p1rdt445lv-p1rlv764)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc7e7e51-f849-4bf4-b720-462daeb21932"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e368704b-6c4b-4afb-a577-4b0d7a96dd65"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "2f183098-d22d-473c-bc33-af8fab5902e3", "name": "l(r:p1rdt446lv-p1rlv766)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0727e1f5-f2ca-4e19-9dc3-89e185002e52"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07381934-8e9b-4447-a330-e8af484331f1"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "a5bb6545-64ef-40da-93ad-c0c9ab4b7840", "name": "l(r:p1rdt452lv-p1rlv786)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44f86829-17fc-4e83-b2a5-705454293161"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180adab2-e49b-42e9-9aeb-42be0a7686c5"}}}], "length": {"value": 0.0235153, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "225bdb8e-1f49-441f-8070-f7ca28084a18", "name": "l(r:p1rdm812-p1rlv775)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b4fed6c4-6907-4601-9671-6f83d582dc45"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d00977fb-8d2a-44ca-aa9e-034894d6e280"}}}], "length": {"value": 0.033048600000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "46b762a3-e999-4dbf-9c4f-a1df60636b0d", "name": "l(r:p1rdm812-p1rdt452lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44f86829-17fc-4e83-b2a5-705454293161"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b4fed6c4-6907-4601-9671-6f83d582dc45"}}}], "length": {"value": 0.0176265, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f95d010c-9470-489a-a425-a70c0d0e7256", "name": "l(r:p1rdm814-p1rlv776)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "090024f2-1724-4789-96da-174d1f5e65ec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c5b1f75-47c0-45c3-9ef3-f97a445b242e"}}}], "length": {"value": 0.0217688, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "551a73e5-acdd-437b-a6cc-6aed76529d23", "name": "l(r:p1rdm814-p1rdt453lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d58e1471-844f-46ef-9d9a-43753b1dee25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "090024f2-1724-4789-96da-174d1f5e65ec"}}}], "length": {"value": 0.0176166, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5a95a755-f19a-4c73-a19d-d006865b8bc0", "name": "l(r:p1rdm815-p1rlv819)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ecd0e9ae-cbf4-4435-8a57-ad23e3e037b4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "def7e507-cb62-42f5-8451-b8a742ef4eb2"}}}], "length": {"value": 0.022596800000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cfc97475-b1af-4388-ad2a-4ce25855b710", "name": "l(r:p1rdm815-p1rdt453lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d58e1471-844f-46ef-9d9a-43753b1dee25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ecd0e9ae-cbf4-4435-8a57-ad23e3e037b4"}}}], "length": {"value": 0.0167209, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "316d6767-840f-4299-b109-2097e8d276be", "name": "l(r:p1rdm816-p1rlv777)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2e41779-98fa-453d-b4df-10a5dd61a4b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fb1fca8-7985-4356-a8de-7433fef7a454"}}}], "length": {"value": 0.02155, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f75a9d71-e1a4-402d-bef5-4d848ec31d32", "name": "l(r:p1rdm816-p1rdt454lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b3e7941-9bdd-48f9-a4a5-a553da9bbb57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2e41779-98fa-453d-b4df-10a5dd61a4b5"}}}], "length": {"value": 0.0516187, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d259a7e7-8125-4187-bd47-e94dac2aaab6", "name": "l(r:p1rdm817-p1rlv789)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "87e4ddc3-ccc3-48af-bc35-d7d85f324ee7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9ce2439-fcc7-4965-81ee-f875db83b003"}}}], "length": {"value": 0.0112431, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "61eacf7d-42ae-4dc6-93af-6e874d82465b", "name": "l(r:p1rdm817-p1rdt454lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b3e7941-9bdd-48f9-a4a5-a553da9bbb57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "87e4ddc3-ccc3-48af-bc35-d7d85f324ee7"}}}], "length": {"value": 0.034455, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4b038cb4-9d4c-4388-b73a-07e32d9bdeac", "name": "l(r:p1rdm818-p1rlv800)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf188897-9db5-4ff4-8c5b-5932a8a794cf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3126c61-9602-45cf-8d57-27d26c14ca7e"}}}], "length": {"value": 0.0215285, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ac12c3ae-f77a-49ba-9a39-1cb0876944f4", "name": "l(r:p1rdm818-p1rdt454lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b3e7941-9bdd-48f9-a4a5-a553da9bbb57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf188897-9db5-4ff4-8c5b-5932a8a794cf"}}}], "length": {"value": 0.0352686, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6f93c84f-0710-47ab-a637-536624b07499", "name": "l(r:p1rdm819-p1rlv778)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b757a90a-ade8-486f-90f1-e7c5e13708ba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80d58665-ee8a-4f4e-a906-dc15aa3d8c6f"}}}], "length": {"value": 0.0239474, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8371aa9a-7c91-415a-8947-852337c10539", "name": "l(r:p1rdm819-p1rdt455lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53b40b3c-db5a-4fa0-bedb-f293c6eac473"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b757a90a-ade8-486f-90f1-e7c5e13708ba"}}}], "length": {"value": 0.0220829, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "56703918-b9f0-445c-923f-0b94682269a1", "name": "l(r:p1rdm820-p1rlv787)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea28f170-6bf0-47f7-a089-8375dff2ad4a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0089ee3-0cb4-434c-adc4-c91a8441ef0a"}}}], "length": {"value": 0.0195656, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "36bacdd9-ce23-4cee-9360-b33171a5e6e4", "name": "l(r:p1rdm820-p1rlv811)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea28f170-6bf0-47f7-a089-8375dff2ad4a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "052949b1-9e85-4be7-993c-9e97efda3657"}}}], "length": {"value": 0.0433217, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a9571498-62a2-471e-8799-f99e7d47a967", "name": "l(r:p1rdm820-p1rdt455lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53b40b3c-db5a-4fa0-bedb-f293c6eac473"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea28f170-6bf0-47f7-a089-8375dff2ad4a"}}}], "length": {"value": 0.0172275, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "18797b51-4af7-4275-9dee-63bd226546e9", "name": "l(r:p1rdt456lv-p1rlv837)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6abe982-a205-4607-bacf-08e9d7cb6f54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33492e0f-c907-46c6-a529-503480b642bb"}}}], "length": {"value": 0.0139503, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0a607995-b86f-4370-a9b7-e32ca59422de", "name": "l(r:p1rdm822-p1rlv779)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3cae47a-4077-44e6-9761-fc30d85c3442"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fbc761bf-480c-465c-9479-279832c50bc2"}}}], "length": {"value": 0.0269896, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f52fa39d-c9fd-4e85-85bc-c2a8df92edbc", "name": "l(r:p1rdm822-p1rdt456lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6abe982-a205-4607-bacf-08e9d7cb6f54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3cae47a-4077-44e6-9761-fc30d85c3442"}}}], "length": {"value": 0.0541811, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "656582d9-cadf-4851-9af9-1fedf3643435", "name": "l(r:p1rdm823-p1rlv831)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84ca6719-0bbc-440a-b0eb-23b8f32dcf47"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4b6c4e-78d0-4c8e-907c-619f1e43c149"}}}], "length": {"value": 0.0211142, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c7c588e1-b801-4e20-968d-74dbf8bb0382", "name": "l(r:p1rdm823-p1rdt456lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6abe982-a205-4607-bacf-08e9d7cb6f54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84ca6719-0bbc-440a-b0eb-23b8f32dcf47"}}}], "length": {"value": 0.0102805, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "836ed46a-5f6d-4870-8499-1278a9ec7351", "name": "l(r:p1rdt457lv-p1rlv780)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "866745cc-62c9-429f-8389-fcc5a1710f17"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20dcf67f-f04f-498a-830d-557ba7b4d867"}}}], "length": {"value": 0.0223005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8a6c23db-3a7c-425d-b48b-633fdc42fc2c", "name": "l(r:p1rdm826-p1rlv783)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf7e29df-0880-4c8c-aa5c-c43f24dd820e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d1a96d5-f971-4116-9642-769ef5b97e7c"}}}], "length": {"value": 0.0163209, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7ed37ca1-5449-46b0-8458-47d0591766d5", "name": "l(r:p1rdm826-p1rlv795)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf7e29df-0880-4c8c-aa5c-c43f24dd820e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb137176-0642-4d87-ae40-1b7b0e1cb214"}}}], "length": {"value": 0.0159024, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1d6bc55d-4607-481e-9105-0b616cb72843", "name": "l(r:p1rdm827-p1rlv791)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8fafab6a-7d1c-4b87-94b3-5bc4d09ff95d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fe9bb3f-e3c1-4b59-b39f-f62271a55bdd"}}}], "length": {"value": 0.0242315, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5bb2309e-ef7a-4950-be3f-4ea437e50a10", "name": "l(r:p1rdm826-p1rdm827)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf7e29df-0880-4c8c-aa5c-c43f24dd820e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8fafab6a-7d1c-4b87-94b3-5bc4d09ff95d"}}}], "length": {"value": 0.0328507, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "dad113c6-9e9e-4700-9435-c7ff0a205da7", "name": "l(r:p1rdm826-p1rdt457lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "866745cc-62c9-429f-8389-fcc5a1710f17"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf7e29df-0880-4c8c-aa5c-c43f24dd820e"}}}], "length": {"value": 0.0167732, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d1330071-2d41-4078-9307-b70a676ad0f8", "name": "l(r:p1rdm829-p1rlv801)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc2d45e2-caa5-4f7d-976e-ccb045c30559"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ecc45b2-1fbe-4a31-995f-e2f8fffe61a7"}}}], "length": {"value": 0.0173132, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6d008500-ace5-48f8-b33f-b4d50e08262d", "name": "l(r:p1rdm829-p1rlv817)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc2d45e2-caa5-4f7d-976e-ccb045c30559"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11064c6f-3b7a-43b5-96ca-7ef96be3815e"}}}], "length": {"value": 0.0169258, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bbc1606e-a1f3-4038-adcb-7d343a8b0784", "name": "l(r:p1rdm829-p1rdt457lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "866745cc-62c9-429f-8389-fcc5a1710f17"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc2d45e2-caa5-4f7d-976e-ccb045c30559"}}}], "length": {"value": 0.0335366, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9afa8eb4-0776-4773-bde9-230acba79717", "name": "l(r:p1rdm831-p1rlv781)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c668ab72-249e-4463-a3b4-863c7fe826c1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98c5ba15-a339-478a-a79f-9298fab16a54"}}}], "length": {"value": 0.0157907, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ec1f3dfe-9be2-448d-895d-a61b55020888", "name": "l(r:p1rdm831-p1rdt458lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67e071ab-e3dc-4779-9e81-585547cd22ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c668ab72-249e-4463-a3b4-863c7fe826c1"}}}], "length": {"value": 0.0148102, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "737caffb-1251-4b71-ad12-6e6bd5bcc4ab", "name": "l(r:p1rdm832-p1rlv843)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "92f03cbf-2585-4e0e-ab0a-cda0b267b34d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3bc013f-c78d-4a3c-b27f-826c3025de0e"}}}], "length": {"value": 0.0182301, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "be49c7ea-d626-4897-b7c0-0ea973232fd8", "name": "l(r:p1rdm832-p1rdt458lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67e071ab-e3dc-4779-9e81-585547cd22ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "92f03cbf-2585-4e0e-ab0a-cda0b267b34d"}}}], "length": {"value": 0.0184885, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5925af09-96ab-46bf-abc1-3ec6d4d2624c", "name": "l(r:p1rdt459lv-p1rlv782)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9eb57d99-ae80-43da-b0cb-b26bdd583e1a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78a4f54a-017a-41b0-85c8-b3e408c21c08"}}}], "length": {"value": 0.0258607, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8d191be9-fb1c-439a-ac8b-e150326846f5", "name": "l(r:p1rdt460lv-p1rlv784)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028bc055-0ee6-4729-8cd2-15bd7153f975"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2823b5b9-bcc3-4b30-9874-89dc33ec80d2"}}}], "length": {"value": 0.0153083, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "01c60984-030f-4370-8898-c1ca4a48a722", "name": "l(r:p1rdt460lv-p1rlv797)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028bc055-0ee6-4729-8cd2-15bd7153f975"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b1c34f1-2613-46aa-9a9f-686ee518e559"}}}], "length": {"value": 0.0114124, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "983e5468-f132-471e-8de4-a2d98111b7bd", "name": "l(r:p1rdm837-p1rlv806)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "790d0b88-fed2-4c90-bfdf-44d3c31d3d8d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d9f269a-e476-4b82-a258-479d812d008d"}}}], "length": {"value": 0.0126883, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2cfbe94b-e247-4450-bba8-f81b935875b7", "name": "l(r:p1rdm835-p1rlv796)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0e1d710-2ab1-43ca-a7c1-8f05a6c0b753"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59662cef-c126-4188-ad86-844f6cabaf34"}}}], "length": {"value": 0.0156616, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4fe3046b-4238-4a56-b548-8a1681e4538b", "name": "l(r:p1rdm835-p1rdm837)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "790d0b88-fed2-4c90-bfdf-44d3c31d3d8d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0e1d710-2ab1-43ca-a7c1-8f05a6c0b753"}}}], "length": {"value": 0.0179452, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2f533d69-4418-47da-be78-5ac5b4c94399", "name": "l(r:p1rdm837-p1rdt460lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028bc055-0ee6-4729-8cd2-15bd7153f975"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "790d0b88-fed2-4c90-bfdf-44d3c31d3d8d"}}}], "length": {"value": 0.0703462, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e073f275-9a06-4a39-b591-4624acf201a2", "name": "l(r:p1rdm838-p1rlv810)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83fdcccd-6a26-4311-aad3-da67dac5af42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb4a881f-684d-48e4-a6f0-5832f73d140a"}}}], "length": {"value": 0.0133783, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a23cc94c-4329-4e58-908f-3f124f3c4745", "name": "l(r:p1rdm839-p1rlv822)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "344c24ef-9d54-4c1a-9aa4-852a76ddbec7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7ce197c-cee4-40df-b1d7-be13f1be8bb1"}}}], "length": {"value": 0.026775, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9052c72c-1afa-4aae-ab91-a44fd081b6e6", "name": "l(r:p1rdm840-p1rlv839)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0649432-ddb6-4648-8efe-27ee1fd959e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48e97be9-1f80-457f-a56e-79f54458c620"}}}], "length": {"value": 0.0161282, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7b128ad7-4208-4cdc-8fe3-a452dcc56bf8", "name": "l(r:p1rdm839-p1rdm840)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "344c24ef-9d54-4c1a-9aa4-852a76ddbec7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0649432-ddb6-4648-8efe-27ee1fd959e4"}}}], "length": {"value": 0.0193155, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6751f34e-86f1-4742-bcbf-9599466eaa30", "name": "l(r:p1rdm838-p1rdm839)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83fdcccd-6a26-4311-aad3-da67dac5af42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "344c24ef-9d54-4c1a-9aa4-852a76ddbec7"}}}], "length": {"value": 0.0193228, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a3012458-a638-42aa-9386-6e16993d49e7", "name": "l(r:p1rdm838-p1rdt460lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028bc055-0ee6-4729-8cd2-15bd7153f975"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83fdcccd-6a26-4311-aad3-da67dac5af42"}}}], "length": {"value": 0.0193155, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0ea070ec-3b8d-4c37-8cf9-11c6930961e5", "name": "l(r:p1rdm841-p1rlv785)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "505b390e-ffd3-482a-8ae9-b8d6bd8be94f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa98d6c6-7086-4033-a9af-c0a33e802942"}}}], "length": {"value": 0.0383319, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "64541dee-7746-4e3a-93ea-f335ec5f5254", "name": "l(r:p1rdm841-p1rdt461lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd9a4931-435b-4b48-907c-024c0b8a4816"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "505b390e-ffd3-482a-8ae9-b8d6bd8be94f"}}}], "length": {"value": 0.0196806, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3ee4a741-0ae5-41a1-9e6f-04e31c8cbce7", "name": "l(r:p1rdm842-p1rlv793)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "172dd9d0-eab4-4481-9edd-f868e6ed87d9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e8c4bc9-0688-43e6-93a8-9664c9b618b7"}}}], "length": {"value": 0.0393311, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e73d98ae-6229-4f85-99ef-3e20d6469868", "name": "l(r:p1rdm842-p1rdt461lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd9a4931-435b-4b48-907c-024c0b8a4816"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "172dd9d0-eab4-4481-9edd-f868e6ed87d9"}}}], "length": {"value": 0.0393612, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "92814b38-b3fd-497d-bd3d-8166ce56fb13", "name": "l(r:p1rdt462lv-p1rlv790)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d96f458-607c-4820-90b1-6fb2625ace7f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf42fa7f-370e-400e-8f6d-76eb8c70ecb9"}}}], "length": {"value": 0.0135001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c513a390-dacc-41d8-84e2-d8c1c494e6af", "name": "l(r:p1rdm843-p1rlv788)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ac64728-e64c-4241-8a3f-b884f11c6393"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9f470d9-6ead-4413-ad8a-7ccc69ae9237"}}}], "length": {"value": 0.0145732, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "78bb8d17-03cd-4ee9-91a7-b347bd572978", "name": "l(r:p1rdm846-p1rlv864)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2086cded-e13c-4683-824e-9e15f99e12e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e2a8871-7bc4-497f-9954-38db92cb3eba"}}}], "length": {"value": 0.0186895, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "13f88096-53de-4f16-99b0-bb6660af5596", "name": "l(r:p1rdm843-p1rdm846)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ac64728-e64c-4241-8a3f-b884f11c6393"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2086cded-e13c-4683-824e-9e15f99e12e8"}}}], "length": {"value": 0.0176441, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c52a3921-ae5b-4628-bddd-3ff0bd8a700c", "name": "l(r:p1rdm843-p1rdt462lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d96f458-607c-4820-90b1-6fb2625ace7f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ac64728-e64c-4241-8a3f-b884f11c6393"}}}], "length": {"value": 0.0186824, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cc7add68-0788-446c-b784-1994d85a83eb", "name": "l(r:p1rdm845-p1rlv840)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b4620a0-c781-422e-8cc7-3ceed9a0c8dc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "024961c3-25f4-4a15-a52a-7f88dc652766"}}}], "length": {"value": 0.046968, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "65243760-4f2f-4d5d-8d33-e47ffe9a3b4c", "name": "l(r:p1rdm845-p1rlv865)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b4620a0-c781-422e-8cc7-3ceed9a0c8dc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abdfa5db-c398-4638-805d-6d55597e1921"}}}], "length": {"value": 0.0131897, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b331290f-e764-4cff-b625-e8475759c1a7", "name": "l(r:p1rdm845-p1rlv867)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b4620a0-c781-422e-8cc7-3ceed9a0c8dc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a7cca48-fd4b-4630-a479-55f2b6ada03b"}}}], "length": {"value": 0.0296877, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "bc9614b3-e07c-4eab-b885-d06bc6380a70", "name": "l(r:p1rdm845-p1rdt462lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d96f458-607c-4820-90b1-6fb2625ace7f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b4620a0-c781-422e-8cc7-3ceed9a0c8dc"}}}], "length": {"value": 0.0137562, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "25952ee5-154e-4e8f-9fa0-73f87e781bd5", "name": "l(r:p1rdt463lv-p1rlv792)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f660c35e-85f8-4f0e-b03b-806006c76c67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f806232e-0a52-46d5-80f7-7ea3a914137a"}}}], "length": {"value": 0.0161855, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b48f1192-2fba-4630-93a6-3be9d6b52672", "name": "l(r:p1rdm850-p1rlv860)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c397a5a5-21bc-4f4d-9f24-7af1219b70e7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bada1117-5605-4aec-9314-8013ed243e3c"}}}], "length": {"value": 0.0408644, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d33c5ecb-5a3f-4998-a939-ade4ab891a57", "name": "l(r:p1rdm850-p1rdt463lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f660c35e-85f8-4f0e-b03b-806006c76c67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c397a5a5-21bc-4f4d-9f24-7af1219b70e7"}}}], "length": {"value": 0.013479, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2e6bf64f-c3c4-4d85-9090-27d3db1d86e7", "name": "l(r:p1rdt464lv-p1rlv794)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "749e07aa-74ce-40f2-a352-9c55f9914377"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eecc456-41af-4242-ab30-d8ca45d55a2c"}}}], "length": {"value": 0.0144527, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c1905497-9abe-4faa-bd82-2075dd0d3940", "name": "l(r:p1rdm852-p1rlv825)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17b42dae-f856-4945-ba7a-9d3f47e049fe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d209dff6-7a24-41ef-947a-8c6f79c2d65c"}}}], "length": {"value": 0.0239195, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "49992f45-5856-436a-a479-f60b021e18fc", "name": "l(r:p1rdm852-p1rdt464lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "749e07aa-74ce-40f2-a352-9c55f9914377"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17b42dae-f856-4945-ba7a-9d3f47e049fe"}}}], "length": {"value": 0.0188143, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ee5d8865-3fd3-4795-a0b8-dfd4e9a93cac", "name": "l(r:p1rdm853-p1rlv829)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08c93f8a-9600-4ffd-8e18-576d433ce777"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e3a1bd0-69fe-42bb-993d-2094ecc658ce"}}}], "length": {"value": 0.016328, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bccbc133-6fa8-4fa3-a2bc-802cdda86910", "name": "l(r:p1rdm853-p1rdt464lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "749e07aa-74ce-40f2-a352-9c55f9914377"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08c93f8a-9600-4ffd-8e18-576d433ce777"}}}], "length": {"value": 0.0188277, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c3fc0daf-894b-469f-9e4e-90bd63d9f129", "name": "l(r:p1rdm855-p1rlv809)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5ad091a-3b6a-4069-a642-104c28a94dc4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e0f8ee8-795f-4bea-bf7a-e2c477eefb89"}}}], "length": {"value": 0.0141744, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1520e88a-1c47-4c6d-8a0d-2904cb8c3a88", "name": "l(r:p1rdm855-p1rdt465lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "433b0872-49c4-452c-941c-8083a72840ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5ad091a-3b6a-4069-a642-104c28a94dc4"}}}], "length": {"value": 0.0498634, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d406b735-8fac-47c1-b56e-db92b40af1d0", "name": "l(r:p1rdm856-p1rlv862)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eaf112db-b9dc-4d90-b030-3e26188aaf2b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5e2c3a2-32c0-4bb9-9802-265cec784974"}}}], "length": {"value": 0.0132627, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c94f9ba6-f842-44b4-937f-ca55007e9b89", "name": "l(r:p1rdm854-p1rlv798)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb73d9f2-aefb-430c-babd-ac02422eb212"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c30005d7-7e42-4a08-8935-0c7227fba4a6"}}}], "length": {"value": 0.0514932, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "fe2fe4cc-1ca1-49ea-ace0-0dbe19fab608", "name": "l(r:p1rdm854-p1rdm856)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eaf112db-b9dc-4d90-b030-3e26188aaf2b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb73d9f2-aefb-430c-babd-ac02422eb212"}}}], "length": {"value": 0.0253738, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2708a02c-5630-4ed5-bb7d-7e48b577f60a", "name": "l(r:p1rdm856-p1rdt465lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "433b0872-49c4-452c-941c-8083a72840ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eaf112db-b9dc-4d90-b030-3e26188aaf2b"}}}], "length": {"value": 0.0330337, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2d1d33df-5e6c-431b-a65b-5d1417397b37", "name": "l(r:p1rdm857-p1rlv799)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c274aa99-a566-4915-83af-7115bec586b1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f706d9d-0cb1-453b-9ca5-377f7d766099"}}}], "length": {"value": 0.022264, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "10265fad-8f7c-43c0-865e-ed7430319af3", "name": "l(r:p1rdm857-p1rdt466lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f422478c-0d77-48c8-87fb-e883d945f8a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c274aa99-a566-4915-83af-7115bec586b1"}}}], "length": {"value": 0.0280491, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "bc234c0a-aedd-48db-91de-21fa0c5454f3", "name": "l(r:p1rdm858-p1rlv815)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "caa7d639-522c-4fd6-8b74-73a337bd67d2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a134556-828b-4e0c-8773-2f207802e33a"}}}], "length": {"value": 0.011569, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9545bc08-0145-463c-b762-538f3e078558", "name": "l(r:p1rdm858-p1rdt466lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f422478c-0d77-48c8-87fb-e883d945f8a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "caa7d639-522c-4fd6-8b74-73a337bd67d2"}}}], "length": {"value": 0.0785759, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9953a9df-5156-41c7-bec3-13c3ee28db49", "name": "l(r:p1rdt467lv-p1rlv802)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23ed76af-dcb2-4333-ae4c-d7439a37cf87"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2436086-d5c4-4b70-a402-e7d1b6f5b77e"}}}], "length": {"value": 0.023669900000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2548bca4-fda9-4a73-910a-19b98378697f", "name": "l(r:p1rdm861-p1rlv823)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a4bf0e0-92f0-4cd9-afc5-65d9ed242271"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81802469-7320-47e9-b826-fbb33bd371ab"}}}], "length": {"value": 0.0345947, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8f4cba40-f07f-44e4-bac9-1440e21e8bee", "name": "l(r:p1rdm860-p1rlv803)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bfca289-c04c-45d9-8104-40089fc1737e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "018c978c-5673-4090-9792-b75ee161f6d2"}}}], "length": {"value": 0.0184835, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6bde25a7-76c5-4800-9e4b-43f9aeacabc8", "name": "l(r:p1rdm860-p1rdm861)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a4bf0e0-92f0-4cd9-afc5-65d9ed242271"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bfca289-c04c-45d9-8104-40089fc1737e"}}}], "length": {"value": 0.0148709, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fa82ac3a-35f9-4698-aead-a39ffd2d44cf", "name": "l(r:p1rdm861-p1rdt468lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b368fb8f-7f4d-4558-b6b2-2e1db4087727"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a4bf0e0-92f0-4cd9-afc5-65d9ed242271"}}}], "length": {"value": 0.014361200000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "835c6b61-9f3f-4249-9990-71565e51e175", "name": "l(r:p1rdm862-p1rlv833)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1daf402d-faec-4230-b4ab-1efa6283ac0f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eb57fc4-636d-4923-9f4a-d308b062599f"}}}], "length": {"value": 0.019033400000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1b317b7f-25ad-49f7-aeea-76bf76f69a9a", "name": "l(r:p1rdm862-p1rdt468lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b368fb8f-7f4d-4558-b6b2-2e1db4087727"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1daf402d-faec-4230-b4ab-1efa6283ac0f"}}}], "length": {"value": 0.0659529, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "40e9f9b9-d755-457c-ae45-10112f652013", "name": "l(r:p1rdt469lv-p1rlv805)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d12ab15f-746d-462b-b395-e2b330ba1226"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0475b34e-14ab-48e4-9df7-7444de1cde7d"}}}], "length": {"value": 0.0142913, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7eb1f89d-2f21-4647-98bc-44051405b731", "name": "l(r:p1rdt470lv-p1rlv858)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15ab2647-a801-4cb5-a1f7-528118ff5dea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab33ce2f-3131-4cfb-8df2-329fb4aa76b7"}}}], "length": {"value": 0.0299737, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8ee7e39b-981a-4a50-a8aa-4beac6fb4788", "name": "l(r:p1rdm864-p1rlv807)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d861761c-3fe7-437d-917d-8beb24318a42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa259be8-8a61-461a-9e58-d4aaf1ce82db"}}}], "length": {"value": 0.0310907, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "bcb37d15-54f7-4625-abab-989665dada61", "name": "l(r:p1rdm864-p1rdt470lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15ab2647-a801-4cb5-a1f7-528118ff5dea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d861761c-3fe7-437d-917d-8beb24318a42"}}}], "length": {"value": 0.0179311, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5baa0f0e-f822-49b5-9ad4-b3251d29ee4a", "name": "l(r:p1rdt471lv-p1rlv826)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40d98c0b-4c66-4581-9553-f5f57c4b27b9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06746d4d-3db8-45b1-888e-d3d9e405ccaf"}}}], "length": {"value": 0.0163584, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fdac3d14-fa24-42f8-9bae-84816b5ad58b", "name": "l(r:p1rdm866-p1rlv808)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "467753c6-5c1f-4a9d-8a7d-21419b25565f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dcb86a4-e6d7-48b4-b5c2-904635de271b"}}}], "length": {"value": 0.0174196, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0e801fac-7a5f-4816-949a-70e0e49ec4fc", "name": "l(r:p1rdm866-p1rdt471lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40d98c0b-4c66-4581-9553-f5f57c4b27b9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "467753c6-5c1f-4a9d-8a7d-21419b25565f"}}}], "length": {"value": 0.0199112, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "050d509c-ca7e-4b08-84a4-bc625adcd272", "name": "l(r:p1rdt472lv-p1rlv866)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f026a1d3-23b0-4454-a09b-e1c08cc06392"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b4834dc-6bdf-4102-bc13-589392b2e75a"}}}], "length": {"value": 0.0127516, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ed35c9fb-26b6-408a-a136-c0d4237551af", "name": "l(r:p1rdm868-p1rlv812)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0ca3ea5-ad01-4e52-883a-c07805f613dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26fea867-af5f-4213-b9c3-487975d1285e"}}}], "length": {"value": 0.00862481, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "54aae335-7d0d-4c7e-af07-9024a6d3f6cd", "name": "l(r:p1rdm868-p1rdt472lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f026a1d3-23b0-4454-a09b-e1c08cc06392"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0ca3ea5-ad01-4e52-883a-c07805f613dd"}}}], "length": {"value": 0.0108197, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1a29acaa-ce20-4436-aec1-4fbd44cde777", "name": "l(r:p1rdm870-p1rlv813)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aa0c31f-baa3-4db8-87d9-0a4ab9a83a8a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10d44b60-55c0-4d78-abbb-52c8cd67134b"}}}], "length": {"value": 0.0316898, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e094be1d-90f2-49a3-a4e2-2154277e7184", "name": "l(r:p1rdm870-p1rdt473lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f435ec5-8c03-45ba-925b-83bad9501047"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aa0c31f-baa3-4db8-87d9-0a4ab9a83a8a"}}}], "length": {"value": 0.0167209, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c55075c5-7299-40ca-aa59-5710f1dc5ae2", "name": "l(r:p1rdm871-p1rlv818)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67c560cc-d815-41d4-8087-b66beaacb404"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd8c54fd-14d4-46fa-8bef-59c1097d5026"}}}], "length": {"value": 0.0247114, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a4a2af30-2b5e-4c51-8842-5f18a7462994", "name": "l(r:p1rdm871-p1rdt473lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f435ec5-8c03-45ba-925b-83bad9501047"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67c560cc-d815-41d4-8087-b66beaacb404"}}}], "length": {"value": 0.016721, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "33025ab1-b5f9-4e7b-8bc9-e05b23ba208d", "name": "l(r:p1rdt474lv-p1rlv814)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "839858f4-3b18-40c3-86f3-e27225e6aba4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b8065f3-8286-4f99-aa56-b9b631a2f838"}}}], "length": {"value": 0.012214300000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4661a900-6153-47f8-ac49-284e1c025724", "name": "l(r:p1rdt474lv-p1rlv827)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "839858f4-3b18-40c3-86f3-e27225e6aba4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c89db91-40fe-4de6-973e-5d8c23e35080"}}}], "length": {"value": 0.0251297, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "97a99a43-b4cf-4a53-8be1-b6f8c9c9d923", "name": "l(r:p1rdm874-p1rlv816)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ec705b7-fdaa-4eca-96eb-5dabb8256c78"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d6de7c2-fd2c-4071-8e90-1513f521cf87"}}}], "length": {"value": 0.00993642, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5d33e469-fbbc-4dbe-8cc0-037dc6f1521d", "name": "l(r:p1rdm874-p1rdt475lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1be3e20a-3890-4e9c-b568-ca99421e751c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ec705b7-fdaa-4eca-96eb-5dabb8256c78"}}}], "length": {"value": 0.0196806, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3e499df6-5b54-4188-87f6-b114b7ddc9d2", "name": "l(r:p1rdm875-p1rlv834)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c17541ac-d30f-4f0a-9660-f9b9f7012b3a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d437c83c-cbd1-41bf-b455-21123e82d59f"}}}], "length": {"value": 0.0324009, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e4649022-4878-4685-9bfd-6c03c7634b0d", "name": "l(r:p1rdm875-p1rdt475lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1be3e20a-3890-4e9c-b568-ca99421e751c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c17541ac-d30f-4f0a-9660-f9b9f7012b3a"}}}], "length": {"value": 0.0393612, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "aea17153-d289-4fb6-bf02-3c99f43ad7b3", "name": "l(r:p1rdt476lv-p1rlv836)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ffde8c6-9dba-4f13-bda5-a0edf17c736d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12556ab7-c50a-4624-9d84-b85585822245"}}}], "length": {"value": 0.0139229, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d23cc706-758d-4c5f-bfe0-c5d897e7a67d", "name": "l(r:p1rdm878-p1rlv842)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f83e2ade-1911-4124-9fbe-6f482d68eba9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8f304a4-6e39-4288-9b9b-e41bb37c6019"}}}], "length": {"value": 0.015212700000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "34d2a6b1-8462-4bde-bf65-082e9aa25dd8", "name": "l(r:p1rdm878-p1rdt476lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ffde8c6-9dba-4f13-bda5-a0edf17c736d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f83e2ade-1911-4124-9fbe-6f482d68eba9"}}}], "length": {"value": 0.0183516, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1906dc6c-7625-4d68-9c53-d3ec88d367b4", "name": "l(r:p1rdm879-p1rlv868)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "260b560c-e6d6-4069-b67f-067c468a7768"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "009758e3-b4ae-427a-9c30-f2a8bb2953d1"}}}], "length": {"value": 0.0303242, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4573dcbc-735f-4cc2-bedf-3e3bf2bb2e6d", "name": "l(r:p1rdm876-p1rlv820)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5331a4f-ab91-4fea-a301-11b7afb6c8ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41e1e576-4cc9-4fea-9d87-d436f000a675"}}}], "length": {"value": 0.0226825, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "dad50477-3454-429d-889f-7802e2fe03db", "name": "l(r:p1rdm876-p1rdm879)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "260b560c-e6d6-4069-b67f-067c468a7768"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5331a4f-ab91-4fea-a301-11b7afb6c8ca"}}}], "length": {"value": 0.018351400000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2b2c06e9-faf7-4a27-b89e-2fd4aff2d4f9", "name": "l(r:p1rdm879-p1rdt476lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ffde8c6-9dba-4f13-bda5-a0edf17c736d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "260b560c-e6d6-4069-b67f-067c468a7768"}}}], "length": {"value": 0.018351400000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f1cee872-ffd6-4181-91ca-28bc5644d2e5", "name": "l(r:p1rdt477lv-p1rlv821)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7c94703b-303a-4713-95c0-b2933fe0e70b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5578d8b4-7c1e-444f-8d27-8c9bf733f420"}}}], "length": {"value": 0.012208200000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "dae4ec0f-7656-4005-b37e-4f869ca62aaa", "name": "l(r:p1rdt477lv-p1rlv828)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7c94703b-303a-4713-95c0-b2933fe0e70b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08c3f5ef-c2d5-4ce2-8fc7-b665d8cbbab6"}}}], "length": {"value": 0.0188029, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e31a013a-6276-486a-95ad-8156f93c04e3", "name": "l(r:p1rdt478lv-p1rlv824)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c93c776d-68b8-4e4e-8e5e-d5e34003473c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20ce76b6-9305-4525-b77e-b7300edc2c81"}}}], "length": {"value": 0.0283636, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "66a1a477-9441-4daa-8e19-9ae195db32ba", "name": "l(r:p1rdt479lv-p1rlv832)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8037b713-d948-43c9-8370-fb8fcf6dec15"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10373c0d-6a3c-4160-a174-22de447d4c38"}}}], "length": {"value": 0.012648, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1bba640c-d184-4cd8-8d9f-8d718e5d85d0", "name": "l(r:p1rdt480lv-p1rlv835)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "423402f9-4160-481b-9951-a955f8314075"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bc35476-5839-4095-bea5-36e32450b890"}}}], "length": {"value": 0.0370417, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "12477693-3b27-4bb8-9818-8febe1402966", "name": "l(r:p1rdt481lv-p1rlv841)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1761b021-00e0-4880-9f05-62cf67aef0e6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eb6c1b4-f09a-44a5-a13f-64051183736d"}}}], "length": {"value": 0.0229879, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4b8f9b84-3375-44e3-996f-8f2b9b7fc95b", "name": "l(r:p1rdt482lv-p1rlv844)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c445ea76-5167-4d55-b0c5-cc53dadc5b5e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26294827-db76-40b6-b652-1e41efdf15dc"}}}], "length": {"value": 0.0225992, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a38cf1c8-e554-4ff7-9189-f9f0861fb6f3", "name": "l(r:p1rdm887-p1rlv846)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3929a951-8b8b-42e9-a839-40c29e680108"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "145d3757-ca09-45ca-9199-465b6b43fbb7"}}}], "length": {"value": 0.025727, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "72d6b0dd-0037-4a7f-b678-dd0aa4abb16a", "name": "l(r:p1rdm887-p1rdt482lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c445ea76-5167-4d55-b0c5-cc53dadc5b5e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3929a951-8b8b-42e9-a839-40c29e680108"}}}], "length": {"value": 0.0374944, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b6f8b4d2-1bc0-4679-9713-9bcd313232ad", "name": "l(r:p1rdm888-p1rlv848)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0318cdac-5c7b-4711-a0d7-9c7e104c8281"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e484d77-29ac-4903-afa3-f677283db883"}}}], "length": {"value": 0.0169569, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "50bbf606-cb43-4516-91a8-dadf8c13416a", "name": "l(r:p1rdm888-p1rdt482lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c445ea76-5167-4d55-b0c5-cc53dadc5b5e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0318cdac-5c7b-4711-a0d7-9c7e104c8281"}}}], "length": {"value": 0.0374944, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "de9da477-e2e9-4af6-be08-69a14dcb5a12", "name": "l(r:p1rdt483lv-p1rlv845)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "475b6a50-9814-4016-bb88-be5b1b2ac31d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b053d449-b15b-4292-9a73-9b7d104a8e38"}}}], "length": {"value": 0.016859600000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6e28be69-05a4-42ac-ad11-d34b22f52d5d", "name": "l(r:p1rdt483lv-p1rlv851)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "475b6a50-9814-4016-bb88-be5b1b2ac31d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48b5535c-f00d-4b48-a23a-87f3f212302f"}}}], "length": {"value": 0.0190238, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bd6f5a20-0cfc-458e-83ac-da3256bcb423", "name": "l(r:p1rdt483lv-p1rlv859)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "475b6a50-9814-4016-bb88-be5b1b2ac31d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ea0f4f5-2024-45a8-9f8f-f5963e7d2727"}}}], "length": {"value": 0.0273815, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "16ca1d8c-f178-4b98-9b82-1048582e46dc", "name": "l(r:p1rdm892-p1rlv855)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "18ea7daf-9665-4d68-b255-12d41bdb2396"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10611e08-75e2-4422-ac0f-cfb98c7eae4b"}}}], "length": {"value": 0.0184228, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8982efe3-fe34-4f46-8ba6-0da7942cd0e9", "name": "l(r:p1rdm890-p1rlv849)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0398ef91-eeb8-4d34-b05e-e88adabdd487"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a95877ca-8600-4e95-82ac-c51cb82acf16"}}}], "length": {"value": 0.0307799, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "336123d1-06d4-42bc-91ca-b2faf7f420c1", "name": "l(r:p1rdm890-p1rdm892)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "18ea7daf-9665-4d68-b255-12d41bdb2396"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0398ef91-eeb8-4d34-b05e-e88adabdd487"}}}], "length": {"value": 0.0712019, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e18fc9dc-b6c4-48fb-a18a-e11d951be718", "name": "l(r:p1rdm892-p1rdt483lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "475b6a50-9814-4016-bb88-be5b1b2ac31d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "18ea7daf-9665-4d68-b255-12d41bdb2396"}}}], "length": {"value": 0.016043, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0fe81417-b25b-4f18-8740-612e6afbda1c", "name": "l(r:p1rdt484lv-p1rlv847)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f396745a-5edb-4ab8-8bc7-2b181719cbf4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "283142ff-4884-4adc-9d4c-f8615505415a"}}}], "length": {"value": 0.0214364, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cd25035f-8cc9-4351-99d1-da90e1465103", "name": "l(r:p1rdm895-p1rlv856)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e96e4c25-4664-45ae-b77c-9e0047f65c8b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25f84b28-695b-4d32-b96c-914226444b9f"}}}], "length": {"value": 0.0167306, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e2643c5e-63e6-45b4-9a5c-87df5a4bba08", "name": "l(r:p1rdm895-p1rdt484lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f396745a-5edb-4ab8-8bc7-2b181719cbf4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e96e4c25-4664-45ae-b77c-9e0047f65c8b"}}}], "length": {"value": 0.0181803, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e4e3f62f-6a52-4772-8105-017c43ea8625", "name": "l(r:p1rdm896-p1rlv850)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60637f4b-8538-4b21-988c-1b13adecc647"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d49057-9c70-4489-95bb-36b5b574e13d"}}}], "length": {"value": 0.0266685, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c65cddfc-7654-418e-bc98-41fa27f8c007", "name": "l(r:p1rdm896-p1rdt485lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da38ec0a-f37d-4a5c-8da0-93410a8fb475"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60637f4b-8538-4b21-988c-1b13adecc647"}}}], "length": {"value": 0.016779100000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d1a11481-6f65-4363-9e68-bb0fda7a5dc9", "name": "l(r:p1rdm897-p1rlv853)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3464daa0-06b2-4d5d-9901-bb34050fe619"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "365eff25-8ccb-448b-894f-ad662fe6d684"}}}], "length": {"value": 0.0210885, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a013e7d5-c8e8-4c90-8afd-836bd7c9313b", "name": "l(r:p1rdm897-p1rdt485lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da38ec0a-f37d-4a5c-8da0-93410a8fb475"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3464daa0-06b2-4d5d-9901-bb34050fe619"}}}], "length": {"value": 0.014660500000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1fd6bbe3-8659-48dd-aa1f-9e5788d134f1", "name": "l(r:p1rdm898-p1rlv852)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d9b6dee-73e1-43ab-ac9b-7d20fb77b6df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32142941-c546-4356-ba80-123b9128b5de"}}}], "length": {"value": 0.0198361, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c93ddd5b-ec87-4033-ba5f-d8293329e37f", "name": "l(r:p1rdm898-p1rdt486lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5401d366-a5a2-4753-82b7-ce4fa08a1227"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d9b6dee-73e1-43ab-ac9b-7d20fb77b6df"}}}], "length": {"value": 0.03692270000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0dc1cf49-c5f7-475d-958e-e7dfd2b9e65e", "name": "l(r:p1rdm899-p1rlv857)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e5e11ab-e042-4038-85c4-162521871722"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a28cc17a-125d-4b7b-a697-230e3f8853b5"}}}], "length": {"value": 0.0237034, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "00e35878-599e-4958-ab4e-26fccef53f5a", "name": "l(r:p1rdm899-p1rdt486lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5401d366-a5a2-4753-82b7-ce4fa08a1227"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e5e11ab-e042-4038-85c4-162521871722"}}}], "length": {"value": 0.0374944, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b544e958-00d0-45f4-9f80-ee015a8495ec", "name": "l(r:p1rdt487lv-p1rlv854)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47fbd02f-6c12-4bd6-9d6d-2e0cddbfcd88"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2461b6f0-9a40-4b6f-9669-be479da039f3"}}}], "length": {"value": 0.0160302, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7413aa3e-5264-431e-b1ee-96bcb81dc33c", "name": "l(r:p1rdt488lv-p1rlv863)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e517b810-e6b9-4c89-b47d-1921fcf88edc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09a7be46-a1bf-459d-836b-beb64324809b"}}}], "length": {"value": 0.022533, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ac6a59e2-26a8-4380-a237-b8c62ae89797", "name": "l(r:p1rdm901-p1rlv861)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d7f4223-382b-4b9a-9157-baede39de271"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a07d30f-6909-4d74-be8a-1ff8343b4419"}}}], "length": {"value": 0.0239784, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f1b8fe58-3e64-4bad-a83d-6dfa926eb48b", "name": "l(r:p1rdm901-p1rdt488lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e517b810-e6b9-4c89-b47d-1921fcf88edc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d7f4223-382b-4b9a-9157-baede39de271"}}}], "length": {"value": 0.0134887, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b57aaa4c-0468-4c5f-97d9-03a76be33d9d", "name": "l(r:p1rdt489lv-p1rlv869)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25637062-8ca3-4694-a27b-7be93e89fe1f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fb4003d-498a-494d-89ca-f222d921f63a"}}}], "length": {"value": 0.0208895, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "10466c86-9f76-45e1-94a1-237649c34b3b", "name": "l(r:p1rdm7860-p1rlv7783)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "601a7504-69fc-4c21-a1d8-1a59751d439c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd7a84bb-8aa4-4668-9791-a363741823e9"}}}], "length": {"value": 0.0587046, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b9060d54-e5ed-415c-9385-ff4782908000", "name": "l(r:p1rdm7860-p1rdt3776lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ae14df0-ab3b-47ba-9f83-c09f03999c76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "601a7504-69fc-4c21-a1d8-1a59751d439c"}}}], "length": {"value": 0.0312996, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "fe5691e5-0fea-4743-911a-02ac9e6cc1a0", "name": "l(r:p1rdm7861-p1rlv7784)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "391504f7-3b2f-47f0-aadd-47de5c89b16b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24e665a0-3ba6-46a7-bc02-327b6f77c409"}}}], "length": {"value": 0.0188851, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "60a19095-6b29-4d9b-89a0-147f382ffe6f", "name": "l(r:p1rdm7861-p1rdt3776lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ae14df0-ab3b-47ba-9f83-c09f03999c76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "391504f7-3b2f-47f0-aadd-47de5c89b16b"}}}], "length": {"value": 0.016714700000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b3634258-f4ed-44fb-98e6-aab051e298ed", "name": "l(r:p1rdt3777lv-p1rlv7786)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4662f3f5-e75b-4b75-a6d6-7ada745d5cca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af62e3c-9357-4505-a2f6-3b4252dab81b"}}}], "length": {"value": 0.0847582, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2ded4c2a-d082-4ebc-b7cf-7173851ecbf9", "name": "l(r:p1rdm7862-p1rlv7785)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90158ee6-01aa-48ce-867f-8e459e7a5e09"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1571d1a3-a151-4972-8cb1-aeb36b660abc"}}}], "length": {"value": 0.0135756, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cb94f9fd-5645-4d22-80c7-8bbcc0dd1f34", "name": "l(r:p1rdm7862-p1rdt3777lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4662f3f5-e75b-4b75-a6d6-7ada745d5cca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90158ee6-01aa-48ce-867f-8e459e7a5e09"}}}], "length": {"value": 0.0255604, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "17a69667-cf10-4bca-be13-6a7e0e89b592", "name": "l(r:p1rdt5098lv-p1rlv10453)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e734d7a2-9161-41c0-ba78-9f9f87120acd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09926231-b077-4aa6-afd8-acf89744865a"}}}], "length": {"value": 0.011414400000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "37668bd4-db9e-4657-a30f-6537455366f8", "name": "l(r:p1rdt5098lv-p1rlv10468)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e734d7a2-9161-41c0-ba78-9f9f87120acd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a639e8d-ac8c-46e8-a4b5-6c551612b209"}}}], "length": {"value": 0.010426000000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6f4de8f6-9f4d-4326-879d-2b1d1bd70a9b", "name": "l(r:p1rdt5098lv-p1rlv10482)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e734d7a2-9161-41c0-ba78-9f9f87120acd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d40fc87f-1b73-4ed4-a397-dbc94312dcad"}}}], "length": {"value": 0.0457378, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "eb768007-e1fd-4128-843e-a920a8d99c4a", "name": "l(r:p1rdt5098lv-p1rlv10517)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e734d7a2-9161-41c0-ba78-9f9f87120acd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "efd01236-6ba3-424e-829b-3f3950ce6265"}}}], "length": {"value": 0.0527233, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "81dde824-4245-4f8c-a4cf-9db89dc3aeb4", "name": "l(r:p1rdt5548lv-p1rlv11503)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91754be7-2a91-4a0e-9856-43d08ecc7c70"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "773a6b9e-d708-4f7c-a901-9406bcc3dcde"}}}], "length": {"value": 0.0787524, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "e169b7fb-6b4d-42f9-8e7c-3647a7d1c8a2", "name": "l(r:p1rdt5548lv-p1rlv19645)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91754be7-2a91-4a0e-9856-43d08ecc7c70"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7efbb32-55d4-409b-a37f-bf01d0620d40"}}}], "length": {"value": 0.0664224, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "4eeb407c-9ccf-4bbd-b2fb-d4024fbdc2db", "name": "l(r:p1rdm11706-p1rlv19640)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4c77c78-e261-4d17-93ff-caad4d86246b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e90f763-682e-4771-976c-9cd736b72133"}}}], "length": {"value": 0.0418249, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "a13c699c-045f-49d2-b42c-2cdbede20fb5", "name": "l(r:p1rdm11706-p1rdt5548lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91754be7-2a91-4a0e-9856-43d08ecc7c70"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4c77c78-e261-4d17-93ff-caad4d86246b"}}}], "length": {"value": 0.00976661, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "cc6ab775-6ec1-4a88-8795-fda42a10631d", "name": "l(r:p1rdm11719-p1rlv11513)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15ae4af0-db43-4f1b-bd8c-c6be31d034aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84b9d44e-2c8d-4cee-a9d2-327a41ab8dad"}}}], "length": {"value": 0.0190194, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "7790dc5f-cdac-4888-aef5-99f91b95d8f0", "name": "l(r:p1rdm11719-p1rdt5557lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05b867e6-2f18-49e7-9869-55bd5048c201"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15ae4af0-db43-4f1b-bd8c-c6be31d034aa"}}}], "length": {"value": 0.0164873, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "ebcc125c-7f65-4704-b548-f54176c23576", "name": "l(r:p1rdm11720-p1rlv19574)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "effa94d0-34ae-4cbe-b8da-fd1693d47b3a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf457d88-958c-446a-9584-73be8c609bbe"}}}], "length": {"value": 0.0842106, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "d84a4af5-3ffc-4402-94bf-55e2b8fce113", "name": "l(r:p1rdm11720-p1rdt5557lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05b867e6-2f18-49e7-9869-55bd5048c201"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "effa94d0-34ae-4cbe-b8da-fd1693d47b3a"}}}], "length": {"value": 0.0174341, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "9f3e9279-5951-47ea-9614-bfdb64faa25b", "name": "l(r:p1rdt5560lv-p1rlv11516)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5838960-8556-4e4a-95e9-8ba9ffc85141"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86d82a1e-1596-4fb3-9f3d-44c9553396d2"}}}], "length": {"value": 0.034696700000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a10879ee-8cd7-4421-8ad1-8ec8d159db76", "name": "l(r:p1rdt5561lv-p1rlv11517)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "133a0221-0cd5-46d2-af84-e80e7951c96d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "179d1d84-0dfe-4920-a039-009f33bc1d8d"}}}], "length": {"value": 0.0852615, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "3c9c08f9-58e9-4367-aee8-72788caa6a7c"}}}}, {"uuid": "85c749d5-75af-4616-a6ac-4d19148a2db2", "name": "l(r:p1rdt5564lv-p1rlv11521)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8deb73b9-51fc-447d-9da7-14a6dccff646"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8f0f8a2-f528-45bd-8fbd-22f6699fe7e0"}}}], "length": {"value": 0.0157073, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cea46a51-3c46-4491-91ff-28ee6a01fae5", "name": "l(r:p1rdt5566lv-p1rlv11523)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95a5450a-6630-41b8-863f-0c1f3fcfa7ab"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69eba934-3f80-4abc-b5e8-9cdc79aa05a3"}}}], "length": {"value": 0.0858684, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "86229bfc-1da4-4a19-9237-57b2905f74e0", "name": "l(r:p1rdt5568lv-p1rlv11526)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "613d178b-a566-408d-bad0-e4a170eea971"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b97ebb0-09a4-4c42-a10e-e3aff344aa44"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "945a8612-0351-49e2-9f34-8f08e68f05d1", "name": "l(r:p1rdm11742-p1rlv11533)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0460a67f-dcc1-4829-99f8-7a0b6a8cedbc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21b18539-fba6-4b52-b8bf-38c2a6c4abfb"}}}], "length": {"value": 0.05768530000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "93ae1764-d66b-4a19-906e-591b3a1e591f", "name": "l(r:p1rdm11742-p1rlv19643)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0460a67f-dcc1-4829-99f8-7a0b6a8cedbc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f0e181a-fa89-4c5d-a1cb-6080f91331da"}}}], "length": {"value": 0.0190181, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "3dbe6d40-2137-4381-80f7-1f5a50ac28df", "name": "l(r:p1rdm11742-p1rdt5574lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "248e065d-80ed-4926-9625-295c83da6b61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0460a67f-dcc1-4829-99f8-7a0b6a8cedbc"}}}], "length": {"value": 0.00976661, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "793d8149-e4ef-4652-883e-e9f4c27a7e76", "name": "l(r:p1rdm11743-p1rlv19610)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6554d73d-5cf7-4531-a524-78e70b36fd8d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "813f887e-6807-4ffc-90bf-bd30cde9a9df"}}}], "length": {"value": 0.0248503, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "5cc69a86-7b23-4389-bb35-5abe701b58fd", "name": "l(r:p1rdm11743-p1rdt5574lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "248e065d-80ed-4926-9625-295c83da6b61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6554d73d-5cf7-4531-a524-78e70b36fd8d"}}}], "length": {"value": 0.00976769, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "a326f1c4-da78-4141-9db0-66d576e8b34a", "name": "l(r:p1rdt5577lv-p1rlv11540)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21ef4ae6-b80e-49f1-8d00-1cb6e27bc8f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1148946c-8c37-4482-afce-5082cd2b7ad4"}}}], "length": {"value": 0.0511394, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "12bccd3a-fe76-4b06-b5e9-4ecf0bc45c74", "name": "l(r:p1rdt5577lv-p1rlv11540)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1148946c-8c37-4482-afce-5082cd2b7ad4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f79b14c8-e77d-49c1-9336-e7407ad4c94d"}}}], "length": {"value": 0.00462191, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f0e70843-a66a-4f1c-9ec8-537f478ceb4c", "name": "l(r:p1rdt5577lv-p1rlv19608)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21ef4ae6-b80e-49f1-8d00-1cb6e27bc8f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "752bcf04-7a44-42b0-9a46-44c243b78eb5"}}}], "length": {"value": 0.0743006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "8827a427-b95c-48ee-bab2-53830e656715", "name": "l(r:p1rdt5577lv-p1rlv19608)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "752bcf04-7a44-42b0-9a46-44c243b78eb5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f917b142-d59f-4a51-8c3b-913feb53411d"}}}], "length": {"value": 0.0771446, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9b7200ad-1df7-439b-b20d-bb9280f9771d", "name": "l(r:p1rdm13355-p1rlv13033)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5559c15-cdac-4a4d-a2a0-b99c9befb310"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1564c5f9-8b80-41b4-af09-2a55dee0718b"}}}], "length": {"value": 0.014252, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e1bf48e6-13e2-4a91-89cf-5d84620d1588", "name": "l(r:p1rdm13355-p1rdt6261lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9859b30-0238-493e-be1a-cb6717413ba9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5559c15-cdac-4a4d-a2a0-b99c9befb310"}}}], "length": {"value": 0.0141814, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "aa2af72e-9572-4467-97d9-6b9af030b224", "name": "l(r:p1rdm13356-p1rlv13036)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba5e6363-0b23-4726-8013-f3d040511005"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23aae8f1-8b9f-4453-9643-b49ffdc80889"}}}], "length": {"value": 0.0296258, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2ca1fa28-2d13-4dfb-b49d-74e91cec5353", "name": "l(r:p1rdm13356-p1rdt6261lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9859b30-0238-493e-be1a-cb6717413ba9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba5e6363-0b23-4726-8013-f3d040511005"}}}], "length": {"value": 0.0175481, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "17ea358b-1515-4a7e-b9cc-da4cd723e829", "name": "l(r:p1rdt6262lv-p1rlv13034)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2172b57-622b-44c1-8388-f1e2b1def312"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3b7bff1-90da-4ee2-8a0f-8e291a7e8ac8"}}}], "length": {"value": 0.012931, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cd2a9d82-271b-4297-97f5-86ec2233a7f8", "name": "l(r:p1rdt6262lv-p1rlv13040)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2172b57-622b-44c1-8388-f1e2b1def312"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6839f65-9d3b-4bd6-89a4-0c8feb33e98a"}}}], "length": {"value": 0.012931, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cbc3d861-03cf-41fd-9899-1877d9629f93", "name": "l(r:p1rdt6263lv-p1rlv13035)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4717b000-fd39-4647-9fbd-5152323dacee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6d309ef-b082-4022-a265-4891cdcd6db9"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "5f45d635-24d4-4b92-b676-91cb371f21c7", "name": "l(r:p1rdt6264lv-p1rlv13037)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e916c16-525d-4092-b627-ad44b4bf4ee8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f5d04aa-74fb-4d1a-ac91-6c01a56a94b5"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "f0aff012-ca25-4a95-afab-ae5b5acd6b86", "name": "l(r:p1rdt6265lv-p1rlv13038)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6bb5544-e583-4ded-9a10-23be70f5598e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a8b4502-31fd-4dce-8717-9860880075b4"}}}], "length": {"value": 0.0390031, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "407a9766-0e87-492a-a15d-f38706b3f5d7", "name": "l(r:p1rdt6265lv-p1rlv13039)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6bb5544-e583-4ded-9a10-23be70f5598e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34d43081-e4a3-4f1b-8b90-5965458452d0"}}}], "length": {"value": 0.0390031, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1ecf47fb-4c9d-4c2f-9b13-48fc566a1ff4", "name": "l(r:p1rdt6266lv-p1rlv13041)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8af5f9d5-965c-4a0c-a811-67d3bed744ee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60144ce1-d4d6-4725-b543-f881894356a5"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "97e95d76-b07f-4991-830b-e51976983721", "name": "l(r:p1rdt6267lv-p1rlv13042)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0ddd898-3193-4bff-80f4-fd4a7eae9aec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "296cd07e-c2e3-4031-abad-9c870a65105d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "3867ca21-d32f-4f5c-940d-37211d717384", "name": "l(r:p1rdt6488lv-p1rlv13513)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1155c2c-544c-45f4-969f-b3ec4f6773bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3243ca2f-a97e-4fbc-981d-85eded2e5e6b"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "d02d53af-3a36-4ac6-9b80-9d033180548f", "name": "l(r:p1rdt6578lv-p1rlv13823)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "555453a3-3fb7-426a-bbd2-9e588d4bd01d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0ca6e47-afec-4d61-885a-e38176b32444"}}}], "length": {"value": 0.047603, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "846f4229-8275-4972-b164-2502491188e2", "name": "l(r:p1rdm14192-p1rlv13789)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2fe65b3-6fcc-4416-bca4-9a0f6551b801"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47a7519a-b550-41e6-99e3-c2115db425fe"}}}], "length": {"value": 0.049152900000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6f4fa352-b028-47aa-9d50-18a0bb0a9afe", "name": "l(r:p1rdm14192-p1rlv13796)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2fe65b3-6fcc-4416-bca4-9a0f6551b801"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94ac9254-cdbf-4864-b22b-bcfb0a827700"}}}], "length": {"value": 0.0270402, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0b124dff-b54f-45fa-a5d5-8c433190d495", "name": "l(r:p1rdm14192-p1rdt6578lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "555453a3-3fb7-426a-bbd2-9e588d4bd01d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2fe65b3-6fcc-4416-bca4-9a0f6551b801"}}}], "length": {"value": 0.014767000000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e71fa7ac-b9d3-4a12-b0d7-044c378b6c67", "name": "l(r:p1rdm14194-p1rlv13814)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e0be7c1-65b8-4de4-89f2-56b6bf1ea321"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028d5ead-7c34-400b-bcc1-c4d706c965d3"}}}], "length": {"value": 0.0199421, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "09b39023-2ff0-4d96-a0ed-ac8b59606a15", "name": "l(r:p1rdm14194-p1rdt6578lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "555453a3-3fb7-426a-bbd2-9e588d4bd01d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e0be7c1-65b8-4de4-89f2-56b6bf1ea321"}}}], "length": {"value": 0.0147579, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "57580946-6dbd-4b0c-98d1-8cad145603ef", "name": "l(r:p1rdt6580lv-p1rlv13791)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5de250a8-ecca-4ab4-9f09-685aaf92d13d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "251f270f-4238-4fe6-8ab3-f884fca7a42d"}}}], "length": {"value": 0.021088, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "aa0e6dd2-2c0f-4177-a823-a0468aa4d055", "name": "l(r:p1rdt6580lv-p1rlv13810)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5de250a8-ecca-4ab4-9f09-685aaf92d13d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab29ca66-d59b-4aa6-b5f6-165add0bc331"}}}], "length": {"value": 0.0102831, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7a87292e-c6a6-4051-9120-26457ad60aa0", "name": "l(r:p1rdt6580lv-p1rlv13815)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5de250a8-ecca-4ab4-9f09-685aaf92d13d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99957459-46a6-4b2b-9813-69b11ca7dad1"}}}], "length": {"value": 0.0257571, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cd0d76c4-750e-4a91-bf36-2fc25a0839cf", "name": "l(r:p1rdt6580lv-p1rlv13819)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5de250a8-ecca-4ab4-9f09-685aaf92d13d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36c12a74-a2ca-439a-a69f-308dd5cb1207"}}}], "length": {"value": 0.0290939, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "506334ac-668e-40db-b38e-3b096457209b", "name": "l(r:p1rdt6584lv-p1rlv13817)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d944119-3782-49dd-8b24-1f68d8ee687c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e96bcc5b-07c5-4289-aec4-0224395c5e8a"}}}], "length": {"value": 0.0927796, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f4e84bae-8f8c-4be0-8536-cd28853d2d45", "name": "l(r:p1rdm14215-p1rlv13801)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "39af24f1-0fa2-465e-a288-2b620d9e9d59"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "accec892-a236-462d-b714-1178393ec992"}}}], "length": {"value": 0.0671973, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0a048391-5c17-4012-930f-0b72f82b3505", "name": "l(r:p1rdm14215-p1rdt6584lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d944119-3782-49dd-8b24-1f68d8ee687c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "39af24f1-0fa2-465e-a288-2b620d9e9d59"}}}], "length": {"value": 0.0384386, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "15c6bf63-883d-4801-a272-90fa9b89b00d", "name": "l(r:p1rdm14218-p1rlv13822)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32db643a-7c82-4816-8629-7935cab09567"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ade9991-a857-4619-8094-c18f824aaeb9"}}}], "length": {"value": 0.06771510000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6f9c9704-6507-461c-8562-66721f90efd2", "name": "l(r:p1rdm14216-p1rlv13807)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e81f150f-30cd-4c9a-b5b7-7a633633702d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c26fba44-3b81-47de-81e6-522f2daf0534"}}}], "length": {"value": 0.0529333, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "87f002f2-9fae-464e-bb80-cb01a6a0b754", "name": "l(r:p1rdm14216-p1rdm14218)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32db643a-7c82-4816-8629-7935cab09567"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e81f150f-30cd-4c9a-b5b7-7a633633702d"}}}], "length": {"value": 0.0151179, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b1fec959-7ba6-4215-b96e-6ba2d1d19620", "name": "l(r:p1rdm14218-p1rdt6584lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d944119-3782-49dd-8b24-1f68d8ee687c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32db643a-7c82-4816-8629-7935cab09567"}}}], "length": {"value": 0.0151258, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7c60e0a9-3fcc-4eba-95b4-8df243a36579", "name": "l(r:p1rdt6587lv-p1rlv13808)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c587698-7940-4edb-9105-f31f1304f7e9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c795ac7-3b49-4158-996d-2fb1f0337847"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "00db7f54-776f-48ee-8e74-66239598eba8", "name": "l(r:p1rdt6588lv-p1rlv13809)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61045f72-ca3d-4e0d-ac3d-db5fbf099b38"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "687996da-ab03-4544-b0d9-b79b8ac88e95"}}}], "length": {"value": 0.0528036, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7dd2b848-aa22-4412-b1d1-8022419948bd", "name": "l(r:p1rdt6590lv-p1rlv13820)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a289017a-8ab9-4412-857a-694b3aa2c63d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a2caa70b-9143-4676-834b-bfc7cb41330c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "cce20032-6f5e-4e62-a614-f8c3e1c1e558", "name": "l(r:p1rdt6591lv-p1rlv13821)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a7c2e99-857f-4119-be4a-daaca586f056"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66e6c732-919a-4851-9f76-5580ea71669d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "e2cf222a-6a6e-4c2b-88b3-ae9dc77d477b", "name": "l(r:p1rdt7286lv-p1rlv15585)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ad975da-cce7-49cb-be78-20c4abf8975e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17bf6d8f-8215-4294-b921-cc3e34476f1e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "0b6321c0-e593-4fd0-83ef-ccdacf1bca96", "name": "l(r:p1rdt7289lv-p1rlv15590)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56d21681-3c57-4575-af17-f2bbf9874a10"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef2a4478-4644-4bd3-9548-ab1d0be338b5"}}}], "length": {"value": 0.0486531, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a57e0543-e448-4364-97ea-0ec58bfe1197", "name": "l(r:p1rdt7289lv-p1rlv15591)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56d21681-3c57-4575-af17-f2bbf9874a10"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c04c9ad1-4277-47de-9cec-9ce86e17b4f1"}}}], "length": {"value": 0.0486531, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f9dc052c-0cf6-496a-bdae-32b7e4c0991c", "name": "l(r:p1rdt7293lv-p1rlv15595)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9b0c16f-f433-4aa1-8d00-dc1573dfb5e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "629e2259-2a59-4b20-b8bf-7b3b2c4a48f9"}}}], "length": {"value": 0.0100375, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b490b873-d978-4e8e-b731-5d1a1177b231", "name": "l(r:p1rdt7293lv-p1rlv15598)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9b0c16f-f433-4aa1-8d00-dc1573dfb5e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "af6b7d1b-896f-44ac-8038-748c74507253"}}}], "length": {"value": 0.0100375, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "aaeb1a63-1faf-4245-8aac-9d7ee893de31", "name": "l(r:p1rdm16003-p1rlv15599)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c1ea087-8a4d-49ca-af35-b86aed849c98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ae1bbf1-459f-4346-b525-393b7d1dc958"}}}], "length": {"value": 0.05559190000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6a2caec6-4161-4515-ba83-a4255da193f2", "name": "l(r:p1rdm16003-p1rdt7294lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67d2b31-f05a-4160-83ae-55154224a9ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c1ea087-8a4d-49ca-af35-b86aed849c98"}}}], "length": {"value": 0.0102952, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fd8a75f0-e4cc-4f0d-9f5a-a88b8512defb", "name": "l(r:p1rdm16004-p1rlv15618)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84040096-aca8-4cee-8539-83ae8f875e98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "200aa7d8-0a43-4086-b0e7-f63cae75671d"}}}], "length": {"value": 0.0495647, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2f1ec0c6-1240-41df-9dbd-567f072a135c", "name": "l(r:p1rdm16004-p1rdt7294lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67d2b31-f05a-4160-83ae-55154224a9ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84040096-aca8-4cee-8539-83ae8f875e98"}}}], "length": {"value": 0.0103008, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "228ab804-b7eb-4baa-8890-32957676b9b3", "name": "l(r:p1rdm16011-p1rlv15604)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "381018f1-11cd-4519-ad24-d3419116ea84"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95b45d46-b7e7-46e2-98d9-5034e2fa0a17"}}}], "length": {"value": 0.0544244, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8c2aa039-c379-41ae-a2bc-c5676e9b8d5c", "name": "l(r:p1rdm16011-p1rdt7299lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4cee417a-3410-4907-8621-f0d3fcbc047c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "381018f1-11cd-4519-ad24-d3419116ea84"}}}], "length": {"value": 0.011971, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e8772813-cf45-4c0c-bfb1-0fa439dccaa4", "name": "l(r:p1rdm16012-p1rlv15616)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60d0a9cf-54f3-4049-9957-29839b7beb08"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43ed408e-35e2-4bca-9060-a0c211aea1e7"}}}], "length": {"value": 0.05365020000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e0c373ed-e460-4f34-a8d1-eb847e2f7d41", "name": "l(r:p1rdm16012-p1rdt7299lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4cee417a-3410-4907-8621-f0d3fcbc047c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60d0a9cf-54f3-4049-9957-29839b7beb08"}}}], "length": {"value": 0.011961, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7fc7557d-3188-421b-9deb-23156c311c75", "name": "l(r:p1rdt7300lv-p1rlv15605)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "135a6a49-6562-4c6e-a41f-f5f78c0ac3e6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcbee2ff-bf73-4834-bc3c-46fa0cfcad7c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "fb196b4b-b9e0-4682-9687-fc7b48814c94", "name": "l(r:p1rdt7303lv-p1rlv15608)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7cbc8145-b198-46f1-a3fd-55a05637e618"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13d6bce6-9066-43a1-b2b6-00a2a4398958"}}}], "length": {"value": 0.09331, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e5a601cd-32a4-4b1b-9279-6c052d0a0c67", "name": "l(r:p1rdt7308lv-p1rlv15619)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5094655-6494-44a9-b0ff-c5b418dcc11e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905a4857-5d3d-4e51-9ab0-70d634170f92"}}}], "length": {"value": 0.0449182, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "69eca3e0-a956-498c-b4de-f0459f13be05", "name": "l(r:p1rdt7308lv-p1rlv15641)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5094655-6494-44a9-b0ff-c5b418dcc11e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4363602a-eb9c-41b8-8130-7bb839f4eb5a"}}}], "length": {"value": 0.0129519, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8b756ba9-f09a-4289-8963-ac6c4c3bb912", "name": "l(r:p1rdm16029-p1rlv15623)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2fba947f-089b-47f3-8720-e8f3e35c097c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13f790a1-18c0-498f-8525-fbaf0350947b"}}}], "length": {"value": 0.0220545, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "88313a2a-a20c-49c2-b01d-be23bb684a18", "name": "l(r:p1rdm16029-p1rdt7308lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5094655-6494-44a9-b0ff-c5b418dcc11e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2fba947f-089b-47f3-8720-e8f3e35c097c"}}}], "length": {"value": 0.0183549, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "878d6ef7-4b7f-4b3d-9231-3c35685646c9", "name": "l(r:p1rdm16030-p1rlv15625)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "154999cc-f6d5-458a-8504-e4692344d372"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb08eda2-b277-4bfd-9ea0-9c36765400bd"}}}], "length": {"value": 0.011861000000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "af04168d-2e01-467c-a933-57eb91eefb0e", "name": "l(r:p1rdm16030-p1rdt7308lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5094655-6494-44a9-b0ff-c5b418dcc11e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "154999cc-f6d5-458a-8504-e4692344d372"}}}], "length": {"value": 0.0183492, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "44d47663-a161-4cf0-81dd-d72b5e0b2ec5", "name": "l(r:p1rdt7316lv-p1rlv15632)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a289e26d-2d86-4fdf-942b-881b91ca18eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ccbef4c-6bf7-4892-a3b9-b51aca495137"}}}], "length": {"value": 0.0523363, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3d9c792d-1901-46b8-8dbc-84c2d3351fa6", "name": "l(r:p1rdt7317lv-p1rlv15633)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16c465cf-c4ae-4702-ba6c-0b7704eda764"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce7b60c8-43ee-441d-9f18-5b2722dcc0a7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "a62267fd-b877-4828-8016-462ee6d0d601", "name": "l(r:p1rdt7321lv-p1rlv15640)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c855f7bb-1f33-4c3e-9deb-e3f9c5aba07d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83c2de51-1b04-483c-8ce7-14b9e5e027b9"}}}], "length": {"value": 0.0474361, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c3f2a59a-557e-4560-948b-6a25ec8bf2ef", "name": "l(r:p1rdt7737lv-p1rlv16450)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35be767a-53a1-4fe1-b320-9542dd859d97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5f1e7aa-d93a-4164-8bc0-f920259304a8"}}}], "length": {"value": 0.0142506, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "91de1667-194c-462b-b28f-55a17f4f7220", "name": "l(r:p1rdt7737lv-p1rlv16463)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35be767a-53a1-4fe1-b320-9542dd859d97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9c505d7-3fb9-4eb5-89c6-c9c8da32fd05"}}}], "length": {"value": 0.0227335, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3a01d0fe-40b1-4fb5-91ca-df152fa306f6", "name": "l(r:p1rdt7737lv-p1rlv16507)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35be767a-53a1-4fe1-b320-9542dd859d97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27afe70a-9123-4b0c-9f50-b5355aafcf7a"}}}], "length": {"value": 0.020775, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5c538261-665c-4f36-ba3f-f5e3a08578c7", "name": "l(r:p1rdt7737lv-p1rlv16584)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35be767a-53a1-4fe1-b320-9542dd859d97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "344c6b21-94c9-4912-a19e-69fbae5eed27"}}}], "length": {"value": 0.0280855, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4edf7cf8-7538-4d21-8e74-b279ea148c65", "name": "l(r:p1rdt7753lv-p1rlv16475)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7482f0c-eb85-4e30-a09a-eb9f15bbc22b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d400b1b2-8404-4b80-b110-6f96e000314f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "2037b2b1-5524-4eb7-b64a-da1ecb5f7e62", "name": "l(r:p1rdt7757lv-p1rlv16483)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d343e634-0936-4f21-9e2c-079e19f0dfa1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa6db7ee-126d-4aa9-9733-35ff1c1d5992"}}}], "length": {"value": 0.00228078, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "8d48b987-eaf2-497c-a339-efe11a87bf39", "name": "l(r:p1rdt7757lv-p1rlv16530)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d343e634-0936-4f21-9e2c-079e19f0dfa1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0333a34b-4027-4d9a-9d4a-f867c8a317bc"}}}], "length": {"value": 0.0186713, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8b0bb813-8062-412e-b539-04750931dc13", "name": "l(r:p1rdt7757lv-p1rlv16541)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d343e634-0936-4f21-9e2c-079e19f0dfa1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f7be042-6681-4694-872d-a1cb701016c7"}}}], "length": {"value": 0.0208942, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3d9c040a-bb54-4e9d-81b5-25d6fcbcfc1b", "name": "l(r:p1rdt7791lv-p1rlv16573)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28e5f84f-2fac-4b5c-a669-b16988e4d6ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90d9dbe9-f9c9-4a4e-8ada-cb459778687b"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "af1ad058-7c6a-401b-9fc3-fbfea264ffdf", "name": "l(r:p1rdt7795lv-p1rlv16604)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3959f944-18f5-4daa-a454-3c6bfb7158ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f9ecb3f-8b64-4598-a9d1-d794c6800d33"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "504184a8-1f73-4d48-afa4-2910dbbfa798", "name": "l(r:p1rdt8105lv-p1rlv17239)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b2ec0ba-a854-4631-b97a-4674123d6fe6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba567aae-a893-41d3-8fd1-8357d3cab35d"}}}], "length": {"value": 0.00558108, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b78127ef-db34-49e5-8d34-8d267770eee9", "name": "l(r:p1rdt8105lv-p1rlv17280)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b2ec0ba-a854-4631-b97a-4674123d6fe6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac80cbea-e10a-491a-ba36-06e9fcf74217"}}}], "length": {"value": 0.00558108, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2375fd38-e5df-4013-92a0-781fb802e32a", "name": "l(r:p1rdm17827-p1rlv17246)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3a01639-0851-466b-abc6-adf52342e772"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acfdbe95-2d82-463a-9d1f-6fd2688adf16"}}}], "length": {"value": 0.0396397, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b7c185de-5d32-4bcd-8427-c286259946ea", "name": "l(r:p1rdm17827-p1rdt8111lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b639e55-2e33-4582-bb96-06a9d33a3419"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3a01639-0851-466b-abc6-adf52342e772"}}}], "length": {"value": 0.0160058, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "28b5f84b-cd7d-4034-bdb3-e59c4f80545a", "name": "l(r:p1rdm17828-p1rlv17303)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f70da59-a879-487b-802e-6b7158e425ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04eb7e32-e372-4cb0-94a7-ee418f400bda"}}}], "length": {"value": 0.051430000000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "99397bd6-6958-407d-83b1-af4d43cac71b", "name": "l(r:p1rdm17828-p1rdt8111lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b639e55-2e33-4582-bb96-06a9d33a3419"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f70da59-a879-487b-802e-6b7158e425ca"}}}], "length": {"value": 0.0135199, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0854729a-afef-4d01-8859-67d7f6de1981", "name": "l(r:p1rdt8138lv-p1rlv17291)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dca9b40e-ed8a-4f75-a703-91539f6c3075"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04388b89-16fc-40b3-a060-5bc52032874e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "db220af5-3816-480b-9981-eb1fe35cc177", "name": "l(r:p1rdt8146lv-p1rlv17311)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2bee3961-990e-47ac-b49b-d305f8fe0af8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84ebd9bb-dc50-483d-a3c6-044682d4020c"}}}], "length": {"value": 0.0332245, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0b45d3d6-5c46-46c7-9a97-1f1cf5e43e38", "name": "l(r:p1rdt8167lv-p1rlv17345)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ead5953-70f2-4db2-ba4d-d203c91d85c1"}}}], "length": {"value": 0.0506084, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a4e9e272-25a0-4302-8307-7262bf9ce2f9", "name": "l(r:p1rdt8167lv-p1rlv17357)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf6f74e5-7aa3-4333-bd37-3ce486d54a01"}}}], "length": {"value": 0.0618331, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f0a6e60c-8c24-4e7b-b4ef-7d7ae2b515e9", "name": "l(r:p1rdt8167lv-p1rlv17397)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d38cdffb-41be-48aa-8a03-c6525dd01037"}}}], "length": {"value": 0.0760567, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e1f63203-b54e-40d0-92ec-ae5ba164567c", "name": "l(r:p1rdt8167lv-p1rlv17400)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63177299-2842-4e0d-bf17-7bd2b0afe9a2"}}}], "length": {"value": 0.07573210000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "79e8a7fd-cb8f-4c8b-a89e-4c11077e7b55", "name": "l(r:p1rdt8167lv-p1rlv17405)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b50de14e-9a09-4f61-8998-0979f33b0d0a"}}}], "length": {"value": 0.0505674, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ca4872cb-e641-4360-9f84-ce34923edf34", "name": "l(r:p1rdt8167lv-p1rlv17415)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86b2527b-73c3-41c4-8ac2-7cb0e8bc2a7a"}}}], "length": {"value": 0.061751, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "93491f53-d77b-43a1-a403-c39b07514ecb", "name": "l(r:p1rdt8169lv-p1rlv17347)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6349165a-d47a-4cf4-84f9-df5c5f3a0e98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d98640c6-d8aa-44e4-9ecf-5998152d3f7d"}}}], "length": {"value": 0.0224066, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4ebf0f0a-64e1-4007-b6e9-f21155e3226d", "name": "l(r:p1rdt8169lv-p1rlv17351)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6349165a-d47a-4cf4-84f9-df5c5f3a0e98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2695decb-d268-46b2-8604-9c33dc90518b"}}}], "length": {"value": 0.0609432, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ca6b10dd-667c-47af-be39-98f12b391661", "name": "l(r:p1rdt8169lv-p1rlv17403)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6349165a-d47a-4cf4-84f9-df5c5f3a0e98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d61897a-cdac-4b4a-8812-8a8692a3d958"}}}], "length": {"value": 0.038578400000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "31224941-a62e-42aa-ae90-bd7ccc3abecf", "name": "l(r:p1rdt8174lv-p1rlv17353)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4903e82a-8cfb-406e-b4bf-5e01068419a3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f34e3e4e-bebd-4148-bcc7-cbfbecd73a2f"}}}], "length": {"value": 0.0319504, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "55dc7678-dc68-40c6-ba37-585b326681a7", "name": "l(r:p1rdt8174lv-p1rlv17378)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4903e82a-8cfb-406e-b4bf-5e01068419a3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08709e25-b030-4801-ae00-c4879556d8b1"}}}], "length": {"value": 0.0249412, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d5084996-4e4c-4102-b7a5-52e1080ebde5", "name": "l(r:p1rdt8174lv-p1rlv17383)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4903e82a-8cfb-406e-b4bf-5e01068419a3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e1ad135-904d-47ed-ae74-32b38e1c2f88"}}}], "length": {"value": 0.012372, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ced660f6-d339-46dd-ac3a-27e815f3fec5", "name": "l(r:p1rdt8180lv-p1rlv17361)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8e03b63-853e-4cfe-bf4a-3779b2026637"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c705333f-6f1a-4a76-a02e-eaa859e99b70"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "7ef593a9-0e64-4af1-a4bb-e9b4dc9a4c54", "name": "l(r:p1rdt8195lv-p1rlv17385)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "782d6008-7fec-46b6-9461-9e33b79539d3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e835b413-3307-49ef-ad69-cf18a5ae7cfb"}}}], "length": {"value": 0.014752, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4fa1bae6-7d69-404d-b5a5-f546bb5f877c", "name": "l(r:p1rdt8195lv-p1rlv17387)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "782d6008-7fec-46b6-9461-9e33b79539d3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "55382019-a1a5-40fd-b90a-072af40c2258"}}}], "length": {"value": 0.0249337, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "50184f43-49b4-43eb-ae76-8a7342e55633", "name": "l(r:p1rdt8195lv-p1rlv17391)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "782d6008-7fec-46b6-9461-9e33b79539d3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "169a22de-bb0a-4056-8910-151125c4ff9e"}}}], "length": {"value": 0.04456, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "22e31715-a179-406a-9b84-5870965a7242", "name": "l(r:p1rdt8195lv-p1rlv17407)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "782d6008-7fec-46b6-9461-9e33b79539d3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65de341c-589f-4bf9-a708-26fcc94a6c0a"}}}], "length": {"value": 0.0236267, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "121927ec-fbec-42ba-a8a6-4c6dcc5d1eda", "name": "l(r:p1rdt8195lv-p1rlv17417)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "782d6008-7fec-46b6-9461-9e33b79539d3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67003f0f-6690-469e-82c0-63949ee5241e"}}}], "length": {"value": 0.03781860000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "43975839-0903-4efe-99af-43ae782a4892", "name": "l(r:p1rdt8201lv-p1rlv17394)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76e33e4f-05be-44d1-a503-fed82b4da974"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea560bcb-f930-4f42-ae45-3a60f36fdbb7"}}}], "length": {"value": 0.020193, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ef5666b6-f1d1-4f2d-821e-4d9e2a1463fd", "name": "l(r:p1rdt8201lv-p1rlv17416)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76e33e4f-05be-44d1-a503-fed82b4da974"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64a56527-23a9-4229-aa25-f6a45f2187f4"}}}], "length": {"value": 0.020193, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cd54109f-3a49-4194-850b-5de8de484600", "name": "l(r:p1rdt9055lv-p1rlv19616)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c1f6cd8-cde1-45cc-87ca-1355efa38077"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be1b9922-2426-4726-9e5a-bcd33f444b57"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "c2a1e423-e43a-4b10-bdcb-48a75c970e7c", "name": "l(r:p1rdt9086lv-p1rlv19683)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "afb4c195-8bb6-47d5-88f3-76adb9cda250"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19894180-0890-4585-b4e2-55500af3c41a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "4372152f-0c65-44f9-895a-702b26f19bc7", "name": "l(r:p1rdt16394lv-p1rlv37689)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40b03cbe-470d-493a-854a-900557ac20c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f827fe9e-1ffe-456c-a57b-c3374aef8ad8"}}}], "length": {"value": 0.04723960000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "524c37c2-27e8-46cc-b729-44ebdf5bd414", "name": "l(r:p1rdt16394lv-p1rlv37691)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40b03cbe-470d-493a-854a-900557ac20c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da3cd593-6f05-41ba-9609-f6f1e307e998"}}}], "length": {"value": 0.00410964, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4c9840fc-3d55-44fc-8db0-51dd82d5d450", "name": "l(r:p1rdt16394lv-p1rlv37703)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40b03cbe-470d-493a-854a-900557ac20c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01c9efda-0adf-4932-8f54-2938964371d2"}}}], "length": {"value": 0.0432047, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a76599e2-b880-4448-9ff7-838401b7bccf", "name": "l(r:p1rdt16404lv-p1rlv37710)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38b0bd7c-0898-497f-bb24-4add0fd92932"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38bda697-2888-467e-bab0-62896a62503f"}}}], "length": {"value": 0.0546394, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ffd4c0f2-984f-48ca-ae4a-2d2b8d5eb0bf", "name": "l(r:p1rdt16404lv-p1rlv37732)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38b0bd7c-0898-497f-bb24-4add0fd92932"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d998a0-628e-4009-a6c8-07af906f6d43"}}}], "length": {"value": 0.0546394, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0eeb7dd7-662c-47a3-adc7-5124f65037a5", "name": "l(r:p1rdm37174-p1rlv37776)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58dce206-0571-4a37-b24b-2e674e0c0d3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b24da1e-9a6e-4545-9ad4-a9f0e9675fd1"}}}], "length": {"value": 0.020713, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9d4adf81-a656-46b4-8fdf-bcdddc2d9c0e", "name": "l(r:p1rdm37174-p1rdt16424lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23775c66-0b90-443d-8566-491405876e9d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58dce206-0571-4a37-b24b-2e674e0c0d3b"}}}], "length": {"value": 0.0336785, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2366cce2-64c7-41db-b323-61f0fe2e5dc7", "name": "l(r:p1rdm37175-p1rlv37778)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d21a9584-0fe7-48a6-a46e-ac33e948a471"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5aaed5d-8312-4707-a047-634e433bf49f"}}}], "length": {"value": 0.0194998, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ef783c84-43f7-4a0a-936a-3aaf472a6fb0", "name": "l(r:p1rdm37175-p1rdt16424lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23775c66-0b90-443d-8566-491405876e9d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d21a9584-0fe7-48a6-a46e-ac33e948a471"}}}], "length": {"value": 0.0285662, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8694b9ce-6cbf-4036-a00c-87331245e895", "name": "l(r:p1rdt16427lv-p1rlv37782)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "980376ed-54fd-434c-b58e-0bbd6eaa9954"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d7181ee-ef64-4ded-b619-00ac09d55bf5"}}}], "length": {"value": 0.00573548, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4eae6c4e-f0c8-47ad-9770-7091587932fd", "name": "l(r:p1rdt16603lv-p1rlv38046)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26bc650a-6838-4320-8afa-b8d2f22e96e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10be49a0-301a-4c7e-8ab7-49c14e483079"}}}], "length": {"value": 0.0415295, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "192935c2-108d-4a02-b3ff-d3ac800226fe", "name": "l(r:p1rdt16603lv-p1rlv38047)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26bc650a-6838-4320-8afa-b8d2f22e96e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0935a86b-b9fb-4058-8381-a41f67d6c9dd"}}}], "length": {"value": 0.07748250000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9dfd866d-0648-4a36-9c98-283e673729a5", "name": "l(r:p1rdt16603lv-p1rlv38052)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26bc650a-6838-4320-8afa-b8d2f22e96e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9db6122d-1e51-46ac-9cea-ac436e189cd8"}}}], "length": {"value": 0.0376082, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f4afa825-c031-4375-9b60-796aeee0a73b", "name": "l(r:p1rdt16604lv-p1rlv38048)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d31da07-e20a-4fb8-95f4-d91450395471"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5da7ff68-5f4c-4d56-88fc-7736df03c0bf"}}}], "length": {"value": 0.0117955, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d99baf21-59da-4cbb-9e03-56ef465544aa", "name": "l(r:p1rdt16604lv-p1rlv38050)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d31da07-e20a-4fb8-95f4-d91450395471"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cafc6c03-240d-499d-a3d8-983b554dd007"}}}], "length": {"value": 0.0117955, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5a91da0e-f196-45f7-a32f-1a612d6a008a", "name": "l(r:p1rdt16787lv-p1rlv38414)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4a3b828-bddf-4314-b9a5-03b9dfcd2618"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a25b3511-86cf-404e-944f-273d3f94c05a"}}}], "length": {"value": 0.0187798, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e0ebe0a0-cff4-4adc-a9c9-d828f00e3590", "name": "l(r:p1rdt16787lv-p1rlv38419)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4a3b828-bddf-4314-b9a5-03b9dfcd2618"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6e4595c-0ad9-4501-b86f-c559917d4b86"}}}], "length": {"value": 0.0187798, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "707a4e95-c971-4116-beca-a5ce262f9535", "name": "l(r:p1rdt16790lv-p1rlv38417)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c261090-bc22-4d81-9a9e-75227cd7c99e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "201112bb-3dc7-4a15-9af6-155626ac1ae5"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "cd1a8186-c9d0-42df-b760-b1b95294ef03", "name": "l(r:p1rdt16847lv-p1rlv38535)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1abef1d-4ffc-4696-91ca-e81ac36cce61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0764c32-4f46-473a-9a72-cccc45ae28d7"}}}], "length": {"value": 0.048719200000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4f800f6e-aceb-490a-af1d-44e393867585", "name": "l(r:p1rdt16847lv-p1rlv38536)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1abef1d-4ffc-4696-91ca-e81ac36cce61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ff930f9-63f0-4cab-b74a-3db7eb99f9eb"}}}], "length": {"value": 0.048719200000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b4b5a2d0-160e-402a-b64c-8588848606d6", "name": "l(r:p1rdt16911lv-p1rlv38638)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0df1550a-7e69-42e9-8059-3a36ecb3d253"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a3851f7-2dd3-447b-918f-7a8c954f21d1"}}}], "length": {"value": 0.00340852, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "3b3117b3-95cd-4c2a-824d-0ca04943f253", "name": "l(r:p1rdt383-p1rdt384)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d49257c8-f8eb-4024-9c02-461d18cdd3d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d8cd980-268f-4adb-a6ee-70edf7784542"}}}], "length": {"value": 0.318116, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "93296b51-3b73-4395-b23e-a1fae2d4b519", "name": "l(r:p1rdt383-p1rdt384)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d8cd980-268f-4adb-a6ee-70edf7784542"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7adf2f4b-f0fd-4c53-abcf-d90fe1a2b4c4"}}}], "length": {"value": 0.509093, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c81291a8-f04b-4694-98f0-a6fbd57c43e6", "name": "l(r:p1rdt383-p1rdt7300)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9240d01-bf5d-41ed-8c53-c1f04af1a236"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ac1506-77e9-4b90-ad3d-18be099063a9"}}}], "length": {"value": 0.32156200000000007, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1921e62c-1311-4331-a4a5-2237faa7cb47", "name": "l(r:p1rdt7299-p1rdt7316)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d065da7b-7e88-4e63-a47c-959f4d4c6e1c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6322bf4d-0976-4bae-94c0-f76f83ccb9bf"}}}], "length": {"value": 0.0919841, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bc608943-95fd-47cb-acc2-7387939774bf", "name": "l(r:p1rdt7299-p1rdt7321)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b468be25-1324-46ab-9424-887741ca1134"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d065da7b-7e88-4e63-a47c-959f4d4c6e1c"}}}], "length": {"value": 0.051956600000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "46835e0d-5eec-4eb7-8862-1b1840832c2f", "name": "l(r:p1rdt7308-p1rdt7321)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2e605b4-fe7a-4571-947d-8ae19de627d8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b468be25-1324-46ab-9424-887741ca1134"}}}], "length": {"value": 0.0493128, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c9fea982-3a6d-4605-ba75-13103b955dfa", "name": "l(r:p1rdt7294-p1rdt7308)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a955da2d-e212-4026-b1fb-0021a04ded07"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2e605b4-fe7a-4571-947d-8ae19de627d8"}}}], "length": {"value": 0.06536220000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4ababa0f-34aa-4a8d-9560-2cde2aac808b", "name": "l(r:p1rdt7294-p1rdt7303)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6f24e3a-088a-4d1b-8292-03015289d88e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a955da2d-e212-4026-b1fb-0021a04ded07"}}}], "length": {"value": 0.3131880000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6ccf7fc6-714e-490d-b5be-b1876e6189b0", "name": "l(r:p1rdt7303-p1rdt7317)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48efebbb-c70a-47d3-aae3-0e39088fc455"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e9980c6-3edc-4b4a-be98-cec731419c30"}}}], "length": {"value": 0.34252800000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f7453bad-bc6b-42fc-98f0-7a998cf4dcae", "name": "l(r:p1rdt7303-p1rdt7317)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e9980c6-3edc-4b4a-be98-cec731419c30"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6f24e3a-088a-4d1b-8292-03015289d88e"}}}], "length": {"value": 0.0175612, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "2fbd6f9c-e000-4cd5-97b9-c10833bf3ef6", "name": "l(r:p1rdt7300-p1rdt7317)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05f14a3e-053e-4b65-b962-da7804b9e2c1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48efebbb-c70a-47d3-aae3-0e39088fc455"}}}], "length": {"value": 0.19776300000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "32e79415-33cb-4732-b18b-558714277e5f", "name": "l(r:p1rdt6488-p1rdt7300)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47f8ed28-4bff-47d9-8ffe-4509e9c5b7fc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b96c1e20-68ac-4548-a068-86483c7fa921"}}}], "length": {"value": 0.249926, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a5a2b4bb-a84e-4fbd-8dfa-9a13f2336af4", "name": "l(r:p1rdt6488-p1rdt7300)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b96c1e20-68ac-4548-a068-86483c7fa921"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05f14a3e-053e-4b65-b962-da7804b9e2c1"}}}], "length": {"value": 0.473615, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7a97e04c-3261-43b6-9af9-b42fd68f65e5", "name": "l(r:p1rdt7795-p1rdt9086)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bee93ff6-6ff8-4572-b339-c8e897dac81b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75ee3b24-7407-45ba-94d5-abe187306f13"}}}], "length": {"value": 0.841194, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f85e851f-dc0f-4e6f-a583-3f1ae28d2fe2", "name": "l(r:p1rdt7757-p1rdt7795)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0cd22d3e-1e2a-4a99-9967-b9df95837915"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bee93ff6-6ff8-4572-b339-c8e897dac81b"}}}], "length": {"value": 0.262663, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c80754fc-5960-4d67-a8f1-a5785ee8c97b", "name": "l(r:p1rdt6261-p1rdt6262)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53e5fee4-5a31-448e-8bd0-d8996468d085"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c00c7b1-0aec-4669-9679-cbc1476e0526"}}}], "length": {"value": 0.107372, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6d1cc6e8-e5d0-4689-a499-12aef7ccd279", "name": "l(r:p1rdt6261-p1rdt6262)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c00c7b1-0aec-4669-9679-cbc1476e0526"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf092ec9-ecda-4216-9ac0-0bc035973515"}}}], "length": {"value": 0.0187886, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a9a90a2f-c40a-4110-9de4-a8cb8e889ceb", "name": "l(r:p1rdt6261-p1rdt6263)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53e5fee4-5a31-448e-8bd0-d8996468d085"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c61df077-693e-4e67-aea6-ee60b99406d1"}}}], "length": {"value": 0.228694, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f2d330e4-2f6f-42b5-a13b-cc2a94adeb93", "name": "l(r:p1rdt6261-p1rdt6266)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e22d08f0-2afc-426a-a0c0-6b00cc1103aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cab917a3-5cc2-46d5-9cee-971591841f12"}}}], "length": {"value": 0.435404, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bae0a560-3e11-4f98-b155-63857b58ce6c", "name": "l(r:p1rdt6261-p1rdt6266)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cab917a3-5cc2-46d5-9cee-971591841f12"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53e5fee4-5a31-448e-8bd0-d8996468d085"}}}], "length": {"value": 0.154284, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "38839979-b995-4ab9-be30-6ae67a71c723", "name": "l(r:p1rdt6264-p1rdt6266)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e22d08f0-2afc-426a-a0c0-6b00cc1103aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a03d20d-664a-4e80-abec-a36910787829"}}}], "length": {"value": 0.0739832, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1bd83f42-c21d-47a8-a7a9-1c20e7f83539", "name": "l(r:p1rdt6266-p1rdt6267)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e22d08f0-2afc-426a-a0c0-6b00cc1103aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b6508ce-e51b-4173-8b54-3f3eb7a2cd71"}}}], "length": {"value": 0.325456, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "286e59cc-f63b-468b-8d9a-61393db7e1ee", "name": "l(r:p1rdt6266-p1rdt6267)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b6508ce-e51b-4173-8b54-3f3eb7a2cd71"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a1d9cfa7-0024-4896-a263-2715086f2ad6"}}}], "length": {"value": 0.120044, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0f94cfbd-4761-471c-9562-5e218d822505", "name": "l(r:p1rdt6266-p1rdt8174)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d07105ef-1ba3-4775-aeb4-650b5ea8736e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e22d08f0-2afc-426a-a0c0-6b00cc1103aa"}}}], "length": {"value": 0.262539, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0ea0f6d8-1d8a-446a-b9d5-e7e260e8acd3", "name": "l(r:p1rdt181-p1rdt66)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79d0fee6-369b-4f95-a2d2-cd05232652e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24681ab1-3904-4509-85e6-d9bb1dba4c8e"}}}], "length": {"value": 0.20085399999999998, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "77e9c9e8-25e0-454f-8acc-7bdc292d928a", "name": "l(r:p1rdt253-p1rdt275)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d4e6a87-0313-419f-8feb-7ea3a29f59ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1a85646-be2b-4b15-9c2f-cc603c7e06df"}}}], "length": {"value": 2.31966, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "dfe7b021-ea88-4223-a261-a2701064e836", "name": "l(r:p1rdt275-p1rdt68)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb9e5f0f-8bcf-4019-a786-3f24334e9ae7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8435bee2-05ea-4208-9520-809129624d70"}}}], "length": {"value": 0.43729, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "63205bf8-f4aa-4db4-9485-c23b17d81f7d", "name": "l(r:p1rdt275-p1rdt68)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8435bee2-05ea-4208-9520-809129624d70"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d4e6a87-0313-419f-8feb-7ea3a29f59ae"}}}], "length": {"value": 0.250359, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "be6f7a14-ab8c-4e37-a3ed-5fabff553d05", "name": "l(r:p1rdt280-p1rdt68)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9cb7919-b8bd-46c1-a173-90a5d241c46e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb9e5f0f-8bcf-4019-a786-3f24334e9ae7"}}}], "length": {"value": 0.601429, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "eb7699dc-41c5-4cce-98f5-4ae362b4e94f", "name": "l(r:p1rdt280-p1rdt281)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac745c6f-6e78-4a68-affa-649f91d3aa7c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4425707e-f2b0-419f-828e-a4642ee34b5a"}}}], "length": {"value": 0.0687501, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "72c50a17-a34a-42f4-8b31-08b3bb5f9d75", "name": "l(r:p1rdt280-p1rdt281)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4425707e-f2b0-419f-828e-a4642ee34b5a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9cb7919-b8bd-46c1-a173-90a5d241c46e"}}}], "length": {"value": 1.11596, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "727137fb-8c02-4156-8941-76e9d1959c6a", "name": "l(r:p1rdt181-p1rdt281)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79d0fee6-369b-4f95-a2d2-cd05232652e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac745c6f-6e78-4a68-affa-649f91d3aa7c"}}}], "length": {"value": 0.20523500000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "27e2b305-6b95-45b4-975d-854d614df5dd", "name": "l(r:p1rdt181-p1rdt297)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2fddf29e-6eef-4c60-ad8b-4580440973b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d87f56c0-0a3f-4a94-8f60-1ece461290d0"}}}], "length": {"value": 0.5067780000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "baaa7a29-c4f4-4a42-9496-71615246d038", "name": "l(r:p1rdt3776-p1rdt3777)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "170a2bcb-d7ce-4617-855b-9111b84262ed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f9af980-79c4-4daf-b8fc-44e02953f98b"}}}], "length": {"value": 0.28751, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ab81c681-02cd-4d20-a59a-bf08c0860df2", "name": "l(r:p1rdt270-p1rdt3776)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7eca59ac-01f1-40d7-a0ec-51f355285e01"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6168ebbc-8fd5-49a0-94db-887814eceaba"}}}], "length": {"value": 0.108215, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "07586677-bd64-4204-9ced-d7f05aca7653", "name": "l(r:p1rdt270-p1rdt3776)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6168ebbc-8fd5-49a0-94db-887814eceaba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "170a2bcb-d7ce-4617-855b-9111b84262ed"}}}], "length": {"value": 2.4603700000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "263d110f-a14b-4b87-b223-8da955f62175", "name": "l(r:p1rdt270-p1rdt298)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2c76250-d7ea-4da4-8008-dac1a579e974"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac7c613f-190c-493e-8e89-3ef48e8efdb9"}}}], "length": {"value": 0.28969, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ce9a3964-79b1-4db7-a902-c27cd390c975", "name": "l(r:p1rdt297-p1rdt298)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d32493ec-06be-48ef-959e-779c79c507a3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a468f13-c61f-4c01-aa27-c75fb02030e0"}}}], "length": {"value": 0.19214800000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b7b9dea7-7dc0-419e-b621-97cdac97877f", "name": "l(r:p1rdt297-p1rdt385)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91f76b91-e00a-4a88-8ee8-ec403c2c7d96"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d32493ec-06be-48ef-959e-779c79c507a3"}}}], "length": {"value": 1.01401, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "724c28f1-72e4-4cfa-a5b6-f43bf9859db4", "name": "l(r:p1rdt252-p1rdt385)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22179eaa-fd19-4619-8b31-52bcb36ec683"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91f76b91-e00a-4a88-8ee8-ec403c2c7d96"}}}], "length": {"value": 1.1732, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "026f2218-a9fc-4fcc-8f34-747194feeaa4", "name": "l(r:p1rdt251-p1rdt254)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9c899bc-796a-4e92-88db-6aa11f8777cb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ab802e3-3a0a-413c-8865-e3b3d08e44a8"}}}], "length": {"value": 0.0898381, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0beb9ff2-61e8-46cf-8fd3-44aa828803d1", "name": "l(r:p1rdt258-p1rdt262)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e28087b-b80e-4043-b0f0-0bc82c91f5e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf660777-f77e-4d9b-afff-73a84274c270"}}}], "length": {"value": 0.208153, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "01d3c056-5715-461b-9acc-d66402ab6122", "name": "l(r:p1rdt258-p1rdt261)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "209cebda-044a-42a3-b2f0-fe5b76b80643"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be0fa139-8da7-4cba-9e49-faf4a4814035"}}}], "length": {"value": 0.38624, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f2c4710f-bc68-4564-84af-92a1aa259cb5", "name": "l(r:p1rdt258-p1rdt261)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be0fa139-8da7-4cba-9e49-faf4a4814035"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e28087b-b80e-4043-b0f0-0bc82c91f5e8"}}}], "length": {"value": 0.00488267, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8bb69a39-5b12-4e4f-b027-85e529e0df0b", "name": "l(r:p1rdt261-p1rdt277)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bbe3ac37-aca0-47fd-ac5d-be390cad10ab"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "209cebda-044a-42a3-b2f0-fe5b76b80643"}}}], "length": {"value": 0.627357, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f3609801-4049-4855-a8a0-afaaec9dfde2", "name": "l(r:p1rdt37-p1rdt80)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a2b529c9-4695-42f3-a0e3-69bbb34ff285"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dcbfdc3-b597-4e9e-a86f-4d0ff396ba70"}}}], "length": {"value": 0.120434, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "aa71e0a2-36e9-45a5-8ce4-23aa9fb93fc5", "name": "l(r:p1rdt34-p1rdt77)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a9c4411-f402-464c-ad25-d439b87ef768"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31b06630-2aae-4fe7-9e31-f911c91121cd"}}}], "length": {"value": 0.034869, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4d75f989-6c51-479c-9043-91fcc989f80c", "name": "l(r:p1rdt34-p1rdt38)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b45513a3-8e88-45e9-99d3-6d244c90c256"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a9c4411-f402-464c-ad25-d439b87ef768"}}}], "length": {"value": 0.0394108, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1116ca8a-ac78-49d1-a542-1aa99e1517ef", "name": "l(r:p1rdt31-p1rdt38)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "668d32be-c07a-4387-86a5-e9754af11e9c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b45513a3-8e88-45e9-99d3-6d244c90c256"}}}], "length": {"value": 0.11407100000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "210bf30a-f181-4110-a885-4370b8e42955", "name": "l(r:p1rdt74-p1rdt85)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b82a9a2-b1d1-44eb-a451-946643ef613d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b884fef-8b8f-4ed5-9033-b8177d1c7d70"}}}], "length": {"value": 0.06744590000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4701ebe3-0051-4850-a1be-a674e0d32c1f", "name": "l(r:p1rdt456-p1rdt489)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf205ba7-ac66-4318-aeca-c75eb96cbd1e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cee642e7-12f0-4746-841e-d8cda6fff57e"}}}], "length": {"value": 0.0171007, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7fcd71f7-07a2-4583-92de-d8b76e4fd4fb", "name": "l(r:p1rdt456-p1rdt465)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b092ee09-4c5e-46b5-8ec2-51f99254c220"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf205ba7-ac66-4318-aeca-c75eb96cbd1e"}}}], "length": {"value": 0.0831843, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3d67899c-d0bf-484f-8833-ae3a12e7848e", "name": "l(r:p1rdt46-p1rdt70)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05082892-d69e-4c8f-ba19-c2a627e1c345"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50f3b5f3-3fb5-4fb9-b2e6-b37200af0901"}}}], "length": {"value": 0.0729594, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f96ebf1e-dadb-4961-b8fe-d0177fe34940", "name": "l(r:p1rdt458-p1rdt46)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b61caefd-d5aa-4019-9ac0-aaf8cedc71d0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05082892-d69e-4c8f-ba19-c2a627e1c345"}}}], "length": {"value": 0.139036, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b72cd657-5085-4543-b5f5-8c6a58f68b97", "name": "l(r:p1rdt52-p1rdt72)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2faff95d-f394-427a-9d62-75224f830c9e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6fb1323-f697-4423-a70d-838056200402"}}}], "length": {"value": 0.0184816, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b002135e-3155-4d9a-b8a6-8d2e34cb07e2", "name": "l(r:p1rdt49-p1rdt72)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "137c345c-77cc-4324-bc0e-e0ba896a5f43"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2faff95d-f394-427a-9d62-75224f830c9e"}}}], "length": {"value": 0.141958, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3db69a18-f698-4e11-bb2f-e1e47b900949", "name": "l(r:p1rdt49-p1rdt56)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1d8f5898-7d36-4e40-9980-76d11ef18adb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "137c345c-77cc-4324-bc0e-e0ba896a5f43"}}}], "length": {"value": 0.148385, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "dc672da8-44a3-4894-9c60-5e070b83e7e1", "name": "l(r:p1rdt472-p1rdt56)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fa14b51-a977-4e40-8f9c-28249e576fcf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1d8f5898-7d36-4e40-9980-76d11ef18adb"}}}], "length": {"value": 0.0472436, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c228649f-9ed3-4986-8dac-f0425e9a697a", "name": "l(r:p1rdt458-p1rdt472)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b61caefd-d5aa-4019-9ac0-aaf8cedc71d0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fa14b51-a977-4e40-8f9c-28249e576fcf"}}}], "length": {"value": 0.0781062, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5f1274d2-0fdd-4db3-ba3f-daa46530bbe0", "name": "l(r:p1rdt458-p1rdt468)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04fc215c-7f3e-45e1-a49c-727b0fcdae93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b61caefd-d5aa-4019-9ac0-aaf8cedc71d0"}}}], "length": {"value": 0.11485, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f4afc337-a6c2-4125-b7fe-0719d5e891df", "name": "l(r:p1rdt50-p1rdt53)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c5d8237-0351-4eb2-83e6-13975b37bfa7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7305e2b-0a48-4630-8b8e-c3819f1c9cd1"}}}], "length": {"value": 0.0672176, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "678b9437-c595-43ea-a97d-0017be14cc4d", "name": "l(r:p1rdt50-p1rdt59)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ea7e0bb-bdc5-429a-8889-2f12c94db72e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c5d8237-0351-4eb2-83e6-13975b37bfa7"}}}], "length": {"value": 0.04918, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "60803bca-2ed6-40da-b226-2af544fcb274", "name": "l(r:p1rdt40-p1rdt59)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "577124ac-ea2b-4a60-be47-14b0f5db305e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ea7e0bb-bdc5-429a-8889-2f12c94db72e"}}}], "length": {"value": 0.0516608, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c2559856-65db-4f83-b07d-064dcaedd41f", "name": "l(r:p1rdt40-p1rdt457)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12fef7fc-57f0-4494-becd-4724b84dbbcb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "577124ac-ea2b-4a60-be47-14b0f5db305e"}}}], "length": {"value": 0.0503098, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e0135291-8bce-40e5-95ba-795bc181843a", "name": "l(r:p1rdt457-p1rdt474)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d709af4b-1115-403b-a68d-76c63c93adf2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12fef7fc-57f0-4494-becd-4724b84dbbcb"}}}], "length": {"value": 0.0841745, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b7308a7d-344b-49a7-8d80-685d673ce399", "name": "l(r:p1rdt468-p1rdt474)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5814195b-dd60-4a1e-9af6-b9b84fa4c0c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d709af4b-1115-403b-a68d-76c63c93adf2"}}}], "length": {"value": 0.047055900000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f21f7000-fa58-438d-b295-aeed9c3310fb", "name": "l(r:p1rdt63-p1rdt65)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9397c58-45a1-4ec3-bd84-b4cd5b52dc80"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab2b6727-4d87-4b00-bd49-ba7a6b1b9ce6"}}}], "length": {"value": 0.0933284, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e85cf5e4-69ad-413f-807d-77e3f696eda8", "name": "l(r:p1rdt467-p1rdt65)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ae86125-88c3-44fb-9fe9-1a5d820606f6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9397c58-45a1-4ec3-bd84-b4cd5b52dc80"}}}], "length": {"value": 0.0141041, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a1591c79-b7e3-488b-963c-3d090d44e462", "name": "l(r:p1rdt467-p1rdt469)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48179f57-b0b9-491b-b654-81583768923a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ae86125-88c3-44fb-9fe9-1a5d820606f6"}}}], "length": {"value": 0.045227800000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bf2293fa-d697-40b8-94a8-bbc3360bdc05", "name": "l(r:p1rdt464-p1rdt469)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a634585d-0c70-428e-a3b2-1ec4717d7878"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48179f57-b0b9-491b-b654-81583768923a"}}}], "length": {"value": 0.0950357, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6164d4c1-cfac-48db-b35f-c1fee483f069", "name": "l(r:p1rdt464-p1rdt480)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e5c3d02-1cd2-45e4-90d3-10b135c65f13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a634585d-0c70-428e-a3b2-1ec4717d7878"}}}], "length": {"value": 0.0188143, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "028d1427-12bf-4d80-a0c8-754796fbd8f3", "name": "l(r:p1rdt473-p1rdt480)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76880999-6f79-4fc6-9367-1c419eee26d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e5c3d02-1cd2-45e4-90d3-10b135c65f13"}}}], "length": {"value": 0.100218, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0eac6646-cb23-4f01-9532-2d11c95be7b3", "name": "l(r:p1rdt453-p1rdt473)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1bb6f93-7aed-47d7-99db-7c17352a42b8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76880999-6f79-4fc6-9367-1c419eee26d5"}}}], "length": {"value": 0.0334417, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "550c5f51-4e56-469e-a157-549ea20e8a21", "name": "l(r:p1rdt452-p1rdt453)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d51e6f65-c45c-4f10-a17f-6ef684a0a06c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1bb6f93-7aed-47d7-99db-7c17352a42b8"}}}], "length": {"value": 0.0352317, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "928cf5c6-ff32-4265-a171-caa8f2190066", "name": "l(r:p1rdt452-p1rdt466)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b20fa59a-8573-461a-9c4a-0d47e40d2601"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d51e6f65-c45c-4f10-a17f-6ef684a0a06c"}}}], "length": {"value": 0.13529, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "fd92e905-34f3-437b-8590-4225eebd2e8e", "name": "l(r:p1rdt466-p1rdt478)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64ba6716-89f9-49a4-9793-ba80ae41bcd0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b20fa59a-8573-461a-9c4a-0d47e40d2601"}}}], "length": {"value": 0.100595, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ee3e7c72-665e-47d8-af76-5876a9d9e1c5", "name": "l(r:p1rdt459-p1rdt471)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12d5c579-0570-44db-a751-8eeb92355af9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eed7e6a8-2b4a-4a54-b69a-e3e1a0614213"}}}], "length": {"value": 0.0917334, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5c3199b2-6cca-49c7-aefa-1566475579bf", "name": "l(r:p1rdt459-p1rdt462)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fcfdc5bf-1c87-42e2-8b35-1f7125d3b5ed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12d5c579-0570-44db-a751-8eeb92355af9"}}}], "length": {"value": 0.0703754, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0db2afbf-8d20-4298-92d5-5f6af25ef9eb", "name": "l(r:p1rdt462-p1rdt487)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfb0d992-ab18-4f73-933e-a01ce73ef3b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fcfdc5bf-1c87-42e2-8b35-1f7125d3b5ed"}}}], "length": {"value": 0.0779035, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e9594c65-f9cd-4dd8-801d-a56ca367ddf8", "name": "l(r:p1rdt16787-p1rdt16790)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4774ed1a-85ec-4ca0-8e9a-3b232588fb0c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4bc644c-9875-4846-8b0f-dfa0568de623"}}}], "length": {"value": 0.0992107, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "cadfd571-1a5b-44b9-9fb5-de61bc3fedf8", "name": "l(r:p1rdt16790-p1rdt16911)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4774ed1a-85ec-4ca0-8e9a-3b232588fb0c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d29266e8-ce67-45bf-93d9-710d4684ce0b"}}}], "length": {"value": 0.388046, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "029ca061-b298-4b43-8c5a-f7ac6278b9be", "name": "l(r:p1rdt16790-p1rdt16911)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d29266e8-ce67-45bf-93d9-710d4684ce0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "725fbd98-74ba-4143-8947-da9fdc209889"}}}], "length": {"value": 3.63254, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b2c407c7-c4ae-4f38-879d-6ee603c0a3ac", "name": "l(r:p1rdt16790-p1rdt487)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d53ff9fd-2b16-4026-88fa-2c112d4949c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a1b5b099-df99-4729-a26d-f0882e93136f"}}}], "length": {"value": 0.110567, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f2ae3c18-4521-4101-98d7-6eb006416a16", "name": "l(r:p1rdt16790-p1rdt487)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a1b5b099-df99-4729-a26d-f0882e93136f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4774ed1a-85ec-4ca0-8e9a-3b232588fb0c"}}}], "length": {"value": 5.746810000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9061f19a-d9eb-48b0-9aa6-ee230b7b9499", "name": "l(r:p1rdt484-p1rdt487)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b57b8e2b-62c2-49a0-801d-02cab8092ebd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfb0d992-ab18-4f73-933e-a01ce73ef3b2"}}}], "length": {"value": 0.0512407, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0a5c4a2b-b730-4d42-aa11-f36b01a58a20", "name": "l(r:p1rdt484-p1rdt486)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd2f4b00-6e8b-4faa-a760-7c28f8d36a36"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b57b8e2b-62c2-49a0-801d-02cab8092ebd"}}}], "length": {"value": 0.0914543, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e4317dc5-b30e-44c0-a5fc-e0c630cfe5d6", "name": "l(r:p1rdt482-p1rdt486)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10c2463d-8563-4737-aa7d-e1195c0af9f6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd2f4b00-6e8b-4faa-a760-7c28f8d36a36"}}}], "length": {"value": 0.018752, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ea04bd86-9e92-4818-a4ff-74fa02d6a46e", "name": "l(r:p1rdt482-p1rdt485)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4064b6c-40b4-418b-95ab-4f9bb0363b14"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10c2463d-8563-4737-aa7d-e1195c0af9f6"}}}], "length": {"value": 0.103372, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "256555f0-2f34-42b5-b04a-e8766a7dd987", "name": "l(r:p1rdt476-p1rdt477)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d1eb09d-dff4-4fa3-b96f-ef59b63d6128"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5421facb-0713-404c-97e9-56669fc762b3"}}}], "length": {"value": 0.0550546, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a651515b-87f2-44e9-827e-68ed7e4d130e", "name": "l(r:p1rdt477-p1rdt479)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85acd1fb-6da3-432a-9508-855ca991641b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d1eb09d-dff4-4fa3-b96f-ef59b63d6128"}}}], "length": {"value": 0.06993920000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8f1ebb1d-e621-479d-aa1b-1d0fea5807b5", "name": "l(r:p1rdt454-p1rdt479)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "82459f47-0c6f-4173-8c35-5a9fe5db9713"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85acd1fb-6da3-432a-9508-855ca991641b"}}}], "length": {"value": 0.0357544, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f6e2d9ab-2762-48b9-8da9-cc62bc28adae", "name": "l(r:p1rdt454-p1rdt455)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "183de04a-a665-4112-a912-1df68b61d164"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "82459f47-0c6f-4173-8c35-5a9fe5db9713"}}}], "length": {"value": 0.0689016, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4816e19f-838d-41f2-a889-d1697bb121b3", "name": "l(r:p1rdt455-p1rdt460)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59b616e5-76b8-406c-843f-5c71398af81b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "183de04a-a665-4112-a912-1df68b61d164"}}}], "length": {"value": 0.0565594, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8ca3ee16-bba0-44b3-a3dd-3ea6a58222ea", "name": "l(r:p1rdt460-p1rdt470)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59b616e5-76b8-406c-843f-5c71398af81b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86178159-ccd7-45a3-b711-ac237321d52a"}}}], "length": {"value": 0.106222, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "06b66ecc-6e3f-4117-a516-0557d7bb1370", "name": "l(r:p1rdt460-p1rdt483)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69b5d686-dae0-44c5-a261-f1a73bcb168e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59b616e5-76b8-406c-843f-5c71398af81b"}}}], "length": {"value": 0.106104, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7bdb4c42-40ee-4d95-8b61-c34a1e59a269", "name": "l(r:p1rdt483-p1rdt485)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d899b807-b194-4f65-bad5-a39e8bc61906"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69b5d686-dae0-44c5-a261-f1a73bcb168e"}}}], "length": {"value": 0.19624000000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ca24f954-e522-4093-b3ca-f315003201e2", "name": "l(r:p1rdt279-p1rdt89)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "232adbbb-2715-44be-8db5-ee062ebf4e46"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "416118a8-65b7-4d9e-90a2-454f065bfddb"}}}], "length": {"value": 0.30139, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "49d16b3e-d9c3-46dd-95bb-e5daf8e7a58c", "name": "l(r:p1rdt279-p1rdt89)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "416118a8-65b7-4d9e-90a2-454f065bfddb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac4ad276-90cb-48c0-bfd0-1f2aa0233ce2"}}}], "length": {"value": 0.197349, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a29ed3d7-71e4-416f-abb4-38952e31a0a5", "name": "l(r:p1rdt16424-p1rdt16427)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d50d3e76-470b-47c2-ada2-da944962b322"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "18e3da78-83fc-4b8e-9d45-41adb9b753ad"}}}], "length": {"value": 0.112509, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ecf392c2-a6e6-4d2c-8690-e08a70243f01", "name": "l(r:p1rdt16427-p1rdt16847)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e35a4f7-19c1-4f59-9adc-b267f6088264"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a6382a2-8c21-4cb4-a39b-3f1ac62cc705"}}}], "length": {"value": 0.160318, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b33f1be7-ab62-4068-9cdd-a6b06ddb0dd2", "name": "l(r:p1rdt16427-p1rdt16847)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a6382a2-8c21-4cb4-a39b-3f1ac62cc705"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d50d3e76-470b-47c2-ada2-da944962b322"}}}], "length": {"value": 3.5139, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "81012bf1-6b78-4db4-9e2c-bad624e98440", "name": "l(r:p1rdt16404-p1rdt16847)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61d5dee2-30f8-434d-8c03-76bccff72549"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e35a4f7-19c1-4f59-9adc-b267f6088264"}}}], "length": {"value": 1.15724, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9ae94c4c-3829-4c79-9e4a-a9d47c147dd6", "name": "l(r:p1rdt16394-p1rdt16404)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5b51836-1807-4fab-b877-94a62021569f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61d5dee2-30f8-434d-8c03-76bccff72549"}}}], "length": {"value": 0.518625, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a4046167-8caa-4f89-90f0-2f76d4ead86f", "name": "l(r:p1rdt16394-p1rdt16603)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5a9e0f5-d824-4a76-a4f0-88aab072280e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5b51836-1807-4fab-b877-94a62021569f"}}}], "length": {"value": 0.709035, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3583561b-9771-4681-a564-fd0842692302", "name": "l(r:p1rdt16603-p1rdt16604)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98a946e8-3c8a-49ec-be8a-5610c7fc596c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5a9e0f5-d824-4a76-a4f0-88aab072280e"}}}], "length": {"value": 0.17277, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "906bae77-46ff-4ffe-aa1a-8abca937d44b", "name": "l(r:p1rdt16604-p1rdt257)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ef71bd7-4c82-4296-a6ac-64516ffe96c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "282d8a89-8b14-476b-9e55-b310d8b9396d"}}}], "length": {"value": 0.261511, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "fd814da9-2a6f-4e0b-b2a0-78a6ae1902b8", "name": "l(r:p1rdt209-p1rdt257)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcb27aab-e828-41a6-ad98-d197897a1a69"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fb307f7-3690-4931-999a-4daab4d8c9e5"}}}], "length": {"value": 0.76493, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "071d214f-abee-4f75-a132-0f7658f857bb", "name": "l(r:p1rdt209-p1rdt210)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d782d5e-3960-415c-9e33-6742777a5a0a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcb27aab-e828-41a6-ad98-d197897a1a69"}}}], "length": {"value": 0.184587, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "530e99b6-8a7f-4641-903b-78a595344f17", "name": "l(r:p1rdt211-p1rdt278)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9401940-26a4-40f3-9b9a-5231a5c4e171"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b89bfea1-97cd-41f7-af59-9602a3fc6c06"}}}], "length": {"value": 0.23979600000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d122d673-6fba-4f7f-84e6-34ad0b010b7b", "name": "l(r:p1rdt210-p1rdt211)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d782d5e-3960-415c-9e33-6742777a5a0a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9401940-26a4-40f3-9b9a-5231a5c4e171"}}}], "length": {"value": 0.156188, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "59cdecc0-9e7a-45b1-97e7-6faaaa4f4ffa", "name": "l(r:p1rdt210-p1rdt44)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1be5e34-ad5e-4c78-8067-8e0194c661a4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d782d5e-3960-415c-9e33-6742777a5a0a"}}}], "length": {"value": 1.1888300000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "11448296-bdc4-4e49-9f35-5b5f6fcea1ef", "name": "l(r:p1rdt259-p1rdt44)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0b5743e-c3fd-49c7-879e-9be7d00c480f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33a0a070-9cce-4a82-bd22-24a65f02ef97"}}}], "length": {"value": 0.515436, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "929db262-2207-4a98-873f-3fe8228c418b", "name": "l(r:p1rdt43-p1rdt47)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7728581d-66fc-4e7e-b2b0-85fa02c90523"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ea0531d-530c-4088-86a1-3de96a8938ea"}}}], "length": {"value": 0.165779, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8725d8ec-6b1e-43d3-aac1-c50e038ef687", "name": "l(r:p1rdt48-p1rdt51)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1667a8c6-aeb4-4f22-97b8-62ffefcc12a4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f5cef5c-bcaf-4cd9-afbb-a18bd14dfcd4"}}}], "length": {"value": 0.04269860000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ef4f28ba-8efb-4df9-b243-d434142431d2", "name": "l(r:p1rdt43-p1rdt48)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7728581d-66fc-4e7e-b2b0-85fa02c90523"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1667a8c6-aeb4-4f22-97b8-62ffefcc12a4"}}}], "length": {"value": 0.175272, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5cc6da99-b1cd-4ddb-a42e-7a75db0bf7a7", "name": "l(r:p1rdt43-p1rdt60)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d99e903-3536-4a73-b0d5-ca11f5af6e32"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7728581d-66fc-4e7e-b2b0-85fa02c90523"}}}], "length": {"value": 0.0427769, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6df6cf40-acb9-42fb-99e3-a21ce4101b90", "name": "l(r:p1rdt58-p1rdt60)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a4ccf80-2611-4089-9353-439809aa7854"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d99e903-3536-4a73-b0d5-ca11f5af6e32"}}}], "length": {"value": 0.0448322, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c70146f3-efa7-47d1-9cbb-88314168e430", "name": "l(r:p1rdt58-p1rdt69)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7238345a-1fc7-4f3f-bc8b-88cf7582c75c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a4ccf80-2611-4089-9353-439809aa7854"}}}], "length": {"value": 0.0519836, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "cfb6c001-f792-4ff8-95cf-625dea85b422", "name": "l(r:p1rdt61-p1rdt71)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bcea1fd6-3c51-48af-8528-d3d7bc8e4f01"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "744725a8-af2a-47cf-948f-9d453a932e32"}}}], "length": {"value": 0.0913144, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "98b2bf94-0765-4f57-860d-b02450dd0b62", "name": "l(r:p1rdt150-p1rdt71)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eab6b8c5-ee7a-4779-b5eb-5205dbe5253c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf5b238a-832f-4f45-8a36-2248549e1723"}}}], "length": {"value": 0.0753659, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d510bfdb-9843-422e-8bb1-2f789219abfc", "name": "l(r:p1rdt150-p1rdt71)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf5b238a-832f-4f45-8a36-2248549e1723"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bcea1fd6-3c51-48af-8528-d3d7bc8e4f01"}}}], "length": {"value": 1.27669, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "de6d22bc-1b8f-4f30-bb8b-c8da620b8eba", "name": "l(r:p1rdt374-p1rdt376)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f2a0358-b10d-4b62-8f8d-9a5054fae87d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d425a00d-c0e9-465d-9d9b-af4d64708fba"}}}], "length": {"value": 0.108011, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ff7901c8-0aff-456b-8d81-a1b8d4a2f3b2", "name": "l(r:p1rdt335-p1rdt376)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0de112ae-d04a-4673-98af-0699e4890429"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f2a0358-b10d-4b62-8f8d-9a5054fae87d"}}}], "length": {"value": 0.20898, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5298fbca-8076-473f-8580-b288d0c98374", "name": "l(r:p1rdt415-p1rdt417)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "101c6236-a474-45c8-b065-f5fa045b1107"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "71fa675e-bc20-46f7-b6f1-c88962f9f3cb"}}}], "length": {"value": 0.074738, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e5c8a281-4e52-4e82-9f86-f4ff7e5c363d", "name": "l(r:p1rdt415-p1rdt419)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19116f3c-29ae-4819-ba72-dd0f8afa5078"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "101c6236-a474-45c8-b065-f5fa045b1107"}}}], "length": {"value": 0.232463, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d9a13636-4929-4a92-891e-92960b15b975", "name": "l(r:p1rdt180-p1rdt5098)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9100fbd6-863e-48b2-94ed-aca1ef0947bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5258d4de-be4c-478d-b752-7f4efb0af0a5"}}}], "length": {"value": 0.41780500000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d3025355-e4bb-43e1-8a1f-b9bd5316b188", "name": "l(r:p1rdt6578-p1rdt6584)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9f273a36-c30d-4962-81f4-26f8d20e1cf4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e257530-1fe2-410b-83a1-57789e6ddeda"}}}], "length": {"value": 0.0679586, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9aa5d5e1-1d2f-4b82-a77d-c3f2172ae856", "name": "l(r:p1rdt6584-p1rdt6588)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9f273a36-c30d-4962-81f4-26f8d20e1cf4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1648fe3-a7f9-47aa-b168-d2b56cf220e7"}}}], "length": {"value": 0.0883424, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1eba036d-0e03-407a-85b6-8ba160dad1b3", "name": "l(r:p1rdt6590-p1rdt6591)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1d0a85a-62dc-46d2-bae1-d43d07743a34"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5291ea2b-6990-407b-b8d4-d6868bf37310"}}}], "length": {"value": 0.043231000000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a5bf29ac-89bd-4638-b20b-ed48bd580674", "name": "l(r:p1rdt6584-p1rdt6591)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9f273a36-c30d-4962-81f4-26f8d20e1cf4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1d0a85a-62dc-46d2-bae1-d43d07743a34"}}}], "length": {"value": 0.125784, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f6953e73-a087-4102-a892-1ebe433cef19", "name": "l(r:p1rdt6584-p1rdt6587)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d77add8e-ba22-4b44-9c0b-0bddc251a573"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b918e583-d163-4136-aaf8-62085c7b0c17"}}}], "length": {"value": 0.115903, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f95cb8d3-6bac-4f3f-9987-04072432b638", "name": "l(r:p1rdt6584-p1rdt6587)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b918e583-d163-4136-aaf8-62085c7b0c17"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9f273a36-c30d-4962-81f4-26f8d20e1cf4"}}}], "length": {"value": 0.0307942, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f6679ba4-efdc-4874-8d11-4cf6f748a362", "name": "l(r:p1rdt6580-p1rdt6587)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68298e92-fca3-44e9-9271-f79be47c9c63"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d77add8e-ba22-4b44-9c0b-0bddc251a573"}}}], "length": {"value": 0.286666, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "818206bb-ebe5-4922-a8c2-df51bbeaebf3", "name": "l(r:p1rdt5098-p1rdt6580)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9100fbd6-863e-48b2-94ed-aca1ef0947bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68298e92-fca3-44e9-9271-f79be47c9c63"}}}], "length": {"value": 0.782623, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "de8392a4-82a2-4c6f-9329-507a13f1a963", "name": "l(r:p1rdt5098-p1rdt8169)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb3d775d-8d92-498b-989c-387278ec8e9e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9100fbd6-863e-48b2-94ed-aca1ef0947bd"}}}], "length": {"value": 0.639283, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "76bbbb7c-66cd-4a27-99f1-bb859a6066fd", "name": "l(r:p1rdt414-p1rdt418)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16b7f1e9-3405-4c5f-96c7-d5c08d791907"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3034e62-dd19-4ecb-bb39-6d0566e3a2ef"}}}], "length": {"value": 0.140409, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1a1011d6-d015-42ba-ac6e-da7e2a76d943", "name": "l(r:p1rdt416-p1rdt418)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16b7f1e9-3405-4c5f-96c7-d5c08d791907"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba78164d-d6ae-413b-8d24-067d8d38b28f"}}}], "length": {"value": 0.317261, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ddd205c9-12db-4ebd-8427-ef30fb02d0cd", "name": "l(r:p1rdt416-p1rdt418)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba78164d-d6ae-413b-8d24-067d8d38b28f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d16d5f5e-a376-4e39-a845-d2cde8800da3"}}}], "length": {"value": 0.00719095, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1ef9f953-073c-41dc-9fab-1bb29279ed90", "name": "l(r:p1rdt418-p1rdt8201)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e3d41a7-06a4-460b-aa6c-3a60c8d2de10"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16b7f1e9-3405-4c5f-96c7-d5c08d791907"}}}], "length": {"value": 0.383696, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "52d6e202-09f8-43f8-a1e1-d5a09e7a420b", "name": "l(r:p1rdt8180-p1rdt8201)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63928702-c44a-4e83-9cca-7ce77bdbd2b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e3d41a7-06a4-460b-aa6c-3a60c8d2de10"}}}], "length": {"value": 0.144684, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1b5efc51-00cf-4947-b82a-1d0bc2f4a0ce", "name": "l(r:p1rdt6265-p1rdt9055)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "246ad62e-5a10-4031-94e7-1732f58f1da9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cd9ea283-dbd2-4f38-b298-86a191c99bd2"}}}], "length": {"value": 0.418878, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d2ad08b2-3802-428b-90bc-4116ddde21dc", "name": "l(r:p1rdt6265-p1rdt9055)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cd9ea283-dbd2-4f38-b298-86a191c99bd2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d316c13-77c1-4412-baf9-801f7e5ae407"}}}], "length": {"value": 0.0741307, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6784aa1f-ad7a-4d72-bb32-3a288b673f0f", "name": "l(r:p1rdt5560-p1rdt9055)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30adfcd5-405b-47ea-be54-55c5a47c835f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "708f65d6-b869-4d26-930d-0e669caf4ffb"}}}], "length": {"value": 0.254007, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "fc1f504a-bedc-4016-b92a-65b5bc1fe559", "name": "l(r:p1rdt5560-p1rdt9055)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "708f65d6-b869-4d26-930d-0e669caf4ffb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "246ad62e-5a10-4031-94e7-1732f58f1da9"}}}], "length": {"value": 0.116066, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "660f83ca-a09b-4b56-aa68-675d218b0194", "name": "l(r:p1rdt7737-p1rdt7753)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d2ea25e-3d48-4b1d-9e52-768752de2e09"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d142315b-a247-4a4d-a178-73e3c150a188"}}}], "length": {"value": 0.0669715, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "48e7142e-612f-4100-8d25-23220ea89d75", "name": "l(r:p1rdt7737-p1rdt7791)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4413ca7f-fdd1-484e-a0ba-3ff2447ebfef"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0946738d-95de-4ad6-9d56-c043cb64c0e4"}}}], "length": {"value": 0.249534, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e62453e6-b369-467e-88c6-b611ede7388d", "name": "l(r:p1rdt7737-p1rdt7791)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0946738d-95de-4ad6-9d56-c043cb64c0e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d2ea25e-3d48-4b1d-9e52-768752de2e09"}}}], "length": {"value": 0.0184373, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "37724e03-70aa-4ea1-8b09-81dd8f5d16fa", "name": "l(r:p1rdt7286-p1rdt7791)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02351140-e632-49e2-83e4-7e5bc1c8856a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4413ca7f-fdd1-484e-a0ba-3ff2447ebfef"}}}], "length": {"value": 0.158647, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "62eb02c6-39e5-4a17-8074-8f98b78fcba3", "name": "l(r:p1rdt7286-p1rdt7289)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f8375b7-7bdd-409c-9fa1-5c13bd233364"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02351140-e632-49e2-83e4-7e5bc1c8856a"}}}], "length": {"value": 0.04388460000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "df4ec83d-e66f-4915-88ba-7af7ae387aea", "name": "l(r:p1rdt7289-p1rdt7293)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f8375b7-7bdd-409c-9fa1-5c13bd233364"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4afa9bec-d8da-4449-ab96-9f875bae3c33"}}}], "length": {"value": 0.16261800000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a4c26044-940e-462b-9054-1e0d4b8c36e4", "name": "l(r:p1rdt5568-p1rdt7289)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c83b6ee-20fc-4ca0-a778-44735283afd5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f8375b7-7bdd-409c-9fa1-5c13bd233364"}}}], "length": {"value": 0.600473, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a4279547-718a-4091-8aa8-b7d14015a34a", "name": "l(r:p1rdt5551-p1rdt5568)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8aa126c-9b2b-4ae0-a4fc-36d4201762a0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65eb08cf-6350-410a-88c2-3b318d3a262a"}}}], "length": {"value": 0.0882294, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1369a137-ea26-496f-a49e-07fe1c36db1c"}}}}, {"uuid": "60d3b874-c356-4c2d-8bcd-365734606fc3", "name": "l(r:p1rdt5551-p1rdt5568)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65eb08cf-6350-410a-88c2-3b318d3a262a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64aba8d5-1dd3-4741-a8ba-26801e275ba8"}}}], "length": {"value": 0.0161184, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a6b9e998-dc46-46e3-b86b-5d83295608dd", "name": "l(r:p1rdt5548-p1rdt5577)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c49b671-0b2b-43c9-bcb5-21c7b7e716ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fead5749-3ba7-4ead-a604-e8adbd18f8c2"}}}], "length": {"value": 0.160305, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1369a137-ea26-496f-a49e-07fe1c36db1c"}}}}, {"uuid": "7ddab2ca-bfb1-4594-b119-011f70f0dd90", "name": "l(r:p1rdt182-p1rdt304)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c51ccb17-eed6-4ce0-b839-e7b26001fe3e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08e378d4-4ca6-4c9e-93fa-36ff87a3cf0f"}}}], "length": {"value": 0.7293, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "129d30ae-597e-45cf-b893-7a0bf9dba703", "name": "l(r:p1rdt304-p1rdt305)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b936973-54dc-41e7-a413-8932c31f0793"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c51ccb17-eed6-4ce0-b839-e7b26001fe3e"}}}], "length": {"value": 0.171066, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "86281a7e-9023-4f94-a293-57e7d50db505", "name": "l(r:p1rdt303-p1rdt305)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9672c49b-8316-4907-b204-7505483210b0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b936973-54dc-41e7-a413-8932c31f0793"}}}], "length": {"value": 0.3440750000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "312c6354-e82f-404e-8e44-2dcf1c65f8bf", "name": "l(r:p1rdt177-p1rdt303)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ad84ef4-4dcc-42f7-99ed-b8d21cebc465"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9672c49b-8316-4907-b204-7505483210b0"}}}], "length": {"value": 0.47439500000000007, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f5774d9c-24b9-411c-a015-e6e4b59caef7", "name": "l(r:p1rdt178-p1rdt306)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57a78c71-e5a8-4dfd-8359-e368b7b198fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6912a245-ac1c-4ddd-b021-3bc35cbbe2c5"}}}], "length": {"value": 1.21943, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c7cb6ba7-cba6-40f8-a51e-07fb728cc8a3", "name": "l(r:p1rdt177-p1rdt306)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ad84ef4-4dcc-42f7-99ed-b8d21cebc465"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57a78c71-e5a8-4dfd-8359-e368b7b198fa"}}}], "length": {"value": 0.644981, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0217c83c-f2af-4c1c-ac7f-0a81411e1e63", "name": "l(r:p1rdt177-p1rdt8105)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3f91816-7c3f-4fc7-98a5-6dee55e52e9f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ad84ef4-4dcc-42f7-99ed-b8d21cebc465"}}}], "length": {"value": 1.4039100000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "2ed246a3-dfad-450b-b7f1-ab6f298571c4", "name": "l(r:p1rdt8105-p1rdt8111)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2c69fef-4afb-4bb3-9828-096b812de54a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37229b7c-80a2-4d01-af6a-818bdfcc1f54"}}}], "length": {"value": 0.0910676, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "12928856-aaca-4156-8f34-04878d8ad992", "name": "l(r:p1rdt8105-p1rdt8111)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37229b7c-80a2-4d01-af6a-818bdfcc1f54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3f91816-7c3f-4fc7-98a5-6dee55e52e9f"}}}], "length": {"value": 0.186172, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "aa0b22a4-6d2d-44c3-bf03-9f5e189ed04f", "name": "l(r:p1rdt8111-p1rdt8146)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2c69fef-4afb-4bb3-9828-096b812de54a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc34073b-94f6-4c75-8144-8f624bac9cc7"}}}], "length": {"value": 0.0135199, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bd0c3d35-c8cb-4701-b32e-a31567ad572d", "name": "l(r:p1rdt8111-p1rdt8138)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9929e0d4-3e33-4f5f-b718-6a629cc52242"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3a54311-da27-45d7-95c3-eee07761fbe4"}}}], "length": {"value": 0.198155, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "817adbcf-58d7-4cf2-b4cb-c18d1bc0c604", "name": "l(r:p1rdt8111-p1rdt8138)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3a54311-da27-45d7-95c3-eee07761fbe4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2c69fef-4afb-4bb3-9828-096b812de54a"}}}], "length": {"value": 0.00299557, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "95236d9f-791c-4a01-a0fd-cb767ec941fa", "name": "l(r:p1rdt251-p1rdt252)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b801037a-e1bb-4c5c-8d18-ed285c8c1d3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69b2ee46-ab5f-48c8-a26b-170ed2b57fcb"}}}], "length": {"value": 0.0455935, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "c1ec8649-6347-41c8-8e9c-1a2e0a37841e", "name": "l(r:p1rdt251-p1rdt446)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3dfe357-889d-42e0-a59a-821c9f843456"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b801037a-e1bb-4c5c-8d18-ed285c8c1d3b"}}}], "length": {"value": 0.620095, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "02b836f0-26df-4939-85a9-506b1779e82b", "name": "l(r:p1rdt468-p1rdt481)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cf3136f-6dbe-4ed7-b9cb-e9f73b191f76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a180b972-cf0e-4a2e-9bcf-a0ad90bb3d83"}}}], "length": {"value": 0.100395, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "dcd73329-a55d-4e12-a3ff-f205c33136f3", "name": "l(r:p1rdt475-p1rdt481)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c39140c6-8892-480a-81b9-738c67ed1591"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cf3136f-6dbe-4ed7-b9cb-e9f73b191f76"}}}], "length": {"value": 0.0369015, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "a299d137-b589-4bab-9836-867f1cdfec55", "name": "l(r:p1rdt461-p1rdt475)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc35f44e-d8d9-41d0-b014-caa3d8d7a91e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c39140c6-8892-480a-81b9-738c67ed1591"}}}], "length": {"value": 0.0590418, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "cc87ca48-40d2-40fa-9407-459ef56a38b8", "name": "l(r:p1rdt461-p1rdt478)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eba354c-f4bf-4c49-a8ad-998ab9489e5a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc35f44e-d8d9-41d0-b014-caa3d8d7a91e"}}}], "length": {"value": 0.0960031, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d6d87a15-b966-4e10-bace-11ae16b68c35", "name": "l(r:p1rdt465-p1rdt478)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a94f7afe-e8b0-4b24-8196-6b05e98c3830"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eba354c-f4bf-4c49-a8ad-998ab9489e5a"}}}], "length": {"value": 0.0203603, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "485b7ea4-6076-4866-bc63-7950ab5f04be", "name": "l(r:p1rdt465-p1rdt488)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fa474a3-1d6b-454b-9170-6a8d13789c43"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a94f7afe-e8b0-4b24-8196-6b05e98c3830"}}}], "length": {"value": 0.148866, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "c56be5eb-6989-4184-86ff-3b60dff1d2be", "name": "l(r:p1rdt463-p1rdt488)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7637cfdb-6a14-4313-95d4-e25beba178f3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fa474a3-1d6b-454b-9170-6a8d13789c43"}}}], "length": {"value": 0.0269677, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "85776a35-68a0-48b2-b32c-4fcf63f765bf", "name": "l(r:p1rdt463-p1rdt82)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7627cbc6-c54a-432b-8cba-59e448f6d45a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7637cfdb-6a14-4313-95d4-e25beba178f3"}}}], "length": {"value": 0.14966800000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "95bc8f10-ed30-43b9-88b7-71e259b40cd0", "name": "l(r:p1rdt78-p1rdt82)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36bfd1f1-80ca-4b7d-a68b-9aa77ceff96e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7627cbc6-c54a-432b-8cba-59e448f6d45a"}}}], "length": {"value": 0.0637409, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "9c2f5d3e-aed7-46b7-a9db-8653f9ca9dab", "name": "l(r:p1rdt78-p1rdt85)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fc415bc-f457-4e9f-bbd4-783a71b67ad6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36bfd1f1-80ca-4b7d-a68b-9aa77ceff96e"}}}], "length": {"value": 0.0375885, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "6a1cad6b-2cac-431d-af4c-21b2a59172a9", "name": "l(r:p1rdt81-p1rdt85)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "063e25be-2abb-49ae-b459-ddd08ba93bb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fc415bc-f457-4e9f-bbd4-783a71b67ad6"}}}], "length": {"value": 0.0219108, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "90683555-cb96-4ee2-8b94-86a64832f1b8", "name": "l(r:p1rdt79-p1rdt81)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b32c9763-ddff-435b-a28c-8f65111c6cb2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "063e25be-2abb-49ae-b459-ddd08ba93bb3"}}}], "length": {"value": 0.0220447, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "372cf68c-8148-4394-a412-526fb4273f82", "name": "l(r:p1rdt76-p1rdt79)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfbb212a-9882-4468-86ac-578c93fde1d8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b32c9763-ddff-435b-a28c-8f65111c6cb2"}}}], "length": {"value": 0.0442698, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "24ae7f1a-6a8a-4a84-aed9-7438bb1bec6e", "name": "l(r:p1rdt31-p1rdt76)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7c543753-fa26-41df-b7a6-3664395c0d45"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfbb212a-9882-4468-86ac-578c93fde1d8"}}}], "length": {"value": 0.117156, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f53f5aae-c274-43c4-b7af-d3041298dfff", "name": "l(r:p1rdt31-p1rdt36)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8dcdfef-b40e-4f1c-9b7c-e84846f68c5a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7c543753-fa26-41df-b7a6-3664395c0d45"}}}], "length": {"value": 0.088569, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "e93867c8-7f0e-49a3-8db2-3f7907cc4bff", "name": "l(r:p1rdt32-p1rdt36)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "834e959c-8ee6-4fff-b1fc-54c20fc0f20b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8dcdfef-b40e-4f1c-9b7c-e84846f68c5a"}}}], "length": {"value": 0.10601200000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "5231e2a7-fda4-48de-a8e5-a4f8a504694d", "name": "l(r:p1rdt234-p1rdt32)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80331f15-8b31-454c-a289-49cb79923252"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "834e959c-8ee6-4fff-b1fc-54c20fc0f20b"}}}], "length": {"value": 0.0518824, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "198b7f01-439d-4fea-bb64-8e615b1d0219", "name": "l(r:p1rdt233-p1rdt485)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f5ed5d5-93fc-4f3c-a78b-df7019863b67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "445f61a4-8045-4558-a3c1-bb44336737ec"}}}], "length": {"value": 0.123436, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "c8e84a6d-4476-4110-8a87-5bff5dfd82d6", "name": "l(r:p1rdt233-p1rdt236)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "190d6c51-94b6-462e-8fee-cce57f1ab66d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f5ed5d5-93fc-4f3c-a78b-df7019863b67"}}}], "length": {"value": 0.0731224, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "ac72dac2-d88d-478e-9c53-c5d07d08999e", "name": "l(r:p1rdt234-p1rdt236)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80331f15-8b31-454c-a289-49cb79923252"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "190d6c51-94b6-462e-8fee-cce57f1ab66d"}}}], "length": {"value": 0.175361, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "bff96efe-7ad7-4117-8d5e-ed34b5e1b0d0", "name": "l(r:p1rdt234-p1rdt235)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14b85850-d83e-4a5e-83c3-ccb485bb85aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80331f15-8b31-454c-a289-49cb79923252"}}}], "length": {"value": 0.10401900000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "4b67aeb5-bf41-404b-b4d6-ed2773d5f4a9", "name": "l(r:p1rdt235-p1rdt30)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fa95a19-0e0a-49b3-bb86-7103fbaa4110"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14b85850-d83e-4a5e-83c3-ccb485bb85aa"}}}], "length": {"value": 0.07237510000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "9e0dc484-5292-4398-b046-2bb0b8595c8c", "name": "l(r:p1rdt30-p1rdt35)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "edc22f66-e919-448e-b990-76033c281d43"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fa95a19-0e0a-49b3-bb86-7103fbaa4110"}}}], "length": {"value": 0.108408, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "57e13003-4b6c-451f-b816-8653b0a58096", "name": "l(r:p1rdt35-p1rdt84)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e9f4b13-5fb5-46b2-9258-83582d47d61a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "edc22f66-e919-448e-b990-76033c281d43"}}}], "length": {"value": 0.0706611, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "30145750-aaff-48a3-b83b-9b27874f2bc3", "name": "l(r:p1rdt33-p1rdt84)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f55e4012-a11d-4883-baac-9c013aff6058"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e9f4b13-5fb5-46b2-9258-83582d47d61a"}}}], "length": {"value": 0.08205580000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f055d7d6-9d6d-4aa0-955c-8987e1322223", "name": "l(r:p1rdt33-p1rdt39)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a01c83d1-4adb-4b2a-8de3-441d7c1dd054"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f55e4012-a11d-4883-baac-9c013aff6058"}}}], "length": {"value": 0.0532669, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "ab5f4002-be54-4c6e-8532-bd6c2fa76205", "name": "l(r:p1rdt39-p1rdt73)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc531967-1a7b-4424-83ee-e1131c6fd94c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a01c83d1-4adb-4b2a-8de3-441d7c1dd054"}}}], "length": {"value": 0.0177535, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "664a630b-6756-439e-a71a-12b73095c4bf", "name": "l(r:p1rdt73-p1rdt75)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "510ea93c-7dd1-4fa3-ba3f-6c362856c7c1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc531967-1a7b-4424-83ee-e1131c6fd94c"}}}], "length": {"value": 0.0510053, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "17c999b3-2206-4299-a8c6-d725bd804b3c", "name": "l(r:p1rdt75-p1rdt83)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aa0b7c2-9d55-4faf-8778-76a6f23bcf3e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "510ea93c-7dd1-4fa3-ba3f-6c362856c7c1"}}}], "length": {"value": 0.0608389, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "a03c0ec0-e778-49bd-babf-57f483e5f78d", "name": "l(r:p1rdt80-p1rdt83)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b03f8e29-a5b2-4bed-b68c-219276674b6a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aa0b7c2-9d55-4faf-8778-76a6f23bcf3e"}}}], "length": {"value": 0.10093, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "8435eda2-aebc-4043-8961-853e603285bf", "name": "l(r:p1rdt263-p1rdt80)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e26e5dc-8c98-4fcd-b125-3265eb00f3f2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b03f8e29-a5b2-4bed-b68c-219276674b6a"}}}], "length": {"value": 0.7842920000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "b8f9d0e5-0e06-4d03-a44d-6fbdf10da8a4", "name": "l(r:p1rdt263-p1rdt277)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "add5e39f-f02e-4a61-a156-d5721cec25d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e26e5dc-8c98-4fcd-b125-3265eb00f3f2"}}}], "length": {"value": 0.731992, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "2f9e0bfb-0ba5-4693-8dbb-8500785d1fa7", "name": "l(r:p1rdt276-p1rdt277)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "186ffdfe-2346-4218-bd6b-b813ea6b3b62"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "add5e39f-f02e-4a61-a156-d5721cec25d5"}}}], "length": {"value": 0.376236, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "095deedb-f5aa-4b88-8ec2-fa9270de8eee", "name": "l(r:p1rdt44-p1rdt69)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9396562e-4f87-4e04-b248-502b851fe19e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1bf1493-fb0d-40b4-8953-42e851a128d1"}}}], "length": {"value": 0.096072, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "16c1200d-d591-4bd8-aa0f-4d52544f6dca", "name": "l(r:p1rdt44-p1rdt69)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1bf1493-fb0d-40b4-8953-42e851a128d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d9ee2ff-e2bc-4d76-b173-5ba5cc48c9b3"}}}], "length": {"value": 0.103033, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d2e808c0-fed6-463f-887f-0e7be56eabd4", "name": "l(r:p1rdt41-p1rdt69)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5b5b3ae-f657-4fd4-a311-ab1dbe9d749e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9396562e-4f87-4e04-b248-502b851fe19e"}}}], "length": {"value": 0.0379066, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "ccf449d9-5f73-457c-ad76-1fc3f639c69d", "name": "l(r:p1rdt41-p1rdt54)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a898f4c-f522-4e69-be4a-e935e339e011"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5b5b3ae-f657-4fd4-a311-ab1dbe9d749e"}}}], "length": {"value": 0.0700668, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "0bf9bcaf-d009-493b-b258-a20b48a817ea", "name": "l(r:p1rdt42-p1rdt54)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a778171c-22a1-4320-9e3c-43888d734e34"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a898f4c-f522-4e69-be4a-e935e339e011"}}}], "length": {"value": 0.0819124, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "fe298b54-0758-4c2f-937f-b4e520788b5d", "name": "l(r:p1rdt42-p1rdt45)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29a79372-9c75-4a9c-81df-a7491b87e58a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a778171c-22a1-4320-9e3c-43888d734e34"}}}], "length": {"value": 0.109393, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "7752518c-dbd5-4bcf-98ba-736e959ee9fd", "name": "l(r:p1rdt150-p1rdt45)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12451cbc-eb14-4814-b274-12eb2241c78a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "666bb367-692a-4127-8f77-d86d651768a1"}}}], "length": {"value": 0.181242, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "1af5f53b-c460-4041-bb80-361236411275", "name": "l(r:p1rdt150-p1rdt45)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "666bb367-692a-4127-8f77-d86d651768a1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29a79372-9c75-4a9c-81df-a7491b87e58a"}}}], "length": {"value": 1.27197, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "9f74db70-41c8-4e3a-954c-bbda4ce07e86", "name": "l(r:p1rdt150-p1rdt260)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba0ef4a3-43ba-469b-8ce8-ca7a5a984071"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e885b3e5-18fb-4454-b8e7-d82b4c72f6e8"}}}], "length": {"value": 0.105488, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "43084528-6f58-47a7-8115-80e604d313d3", "name": "l(r:p1rdt150-p1rdt260)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e885b3e5-18fb-4454-b8e7-d82b4c72f6e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12451cbc-eb14-4814-b274-12eb2241c78a"}}}], "length": {"value": 0.49255100000000007, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "19fa5caf-ed6f-48b1-aef3-26ccfa1abc3b", "name": "l(r:p1rdt260-p1rdt279)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "153bb615-5ee5-4eec-bcf7-94ea0098aeb6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba0ef4a3-43ba-469b-8ce8-ca7a5a984071"}}}], "length": {"value": 0.693281, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "b5f6404e-7ee0-44ba-83b2-4d2a8b780d6d", "name": "l(r:p1rdt276-p1rdt279)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7140d97e-416e-47ec-9f86-46ad6f9abece"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "153bb615-5ee5-4eec-bcf7-94ea0098aeb6"}}}], "length": {"value": 0.296948, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "a22eecf7-0b6c-4b67-b1b6-ef07cf773782", "name": "l(r:p1rdt237-p1rdt276)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3ca9bee-26b0-4ef4-8555-6494ffdd6a17"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "767b59ef-ecd9-4b17-8233-2033a02b2971"}}}], "length": {"value": 0.558882, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "3aa27888-757a-4ade-a479-17348bb56293", "name": "l(r:p1rdt237-p1rdt276)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "767b59ef-ecd9-4b17-8233-2033a02b2971"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "186ffdfe-2346-4218-bd6b-b813ea6b3b62"}}}], "length": {"value": 0.599014, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "3494f392-4b57-4668-b618-de109c41f74b", "name": "l(r:p1rdt237-p1rdt445)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11571d26-573f-49f7-99fd-828dde97afd8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8c8b8f8-7a41-4d16-b509-2d7c7af9509d"}}}], "length": {"value": 0.477235, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "23768e60-635b-4d3f-be8d-50fde874d64a", "name": "l(r:p1rdt438-p1rdt445)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10620dcc-049c-4417-b4ac-922a56c0d4a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11571d26-573f-49f7-99fd-828dde97afd8"}}}], "length": {"value": 0.109204, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "418c0e4f-5a25-445f-91f1-8a7745ad0c0b", "name": "l(r:p1rdt438-p1rdt446)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3dfe357-889d-42e0-a59a-821c9f843456"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10620dcc-049c-4417-b4ac-922a56c0d4a2"}}}], "length": {"value": 0.05910800000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "0e0c3e54-806e-4c0f-9753-303f0f99e48d", "name": "l(r:p1rdt28-p1rdt446)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e71eb2d5-cd10-498d-b9eb-ae337b2f8af6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3dfe357-889d-42e0-a59a-821c9f843456"}}}], "length": {"value": 2.20796, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d440b633-33ea-4a79-a563-f95e7e886d44", "name": "l(r:p1rdt28-p1rdt29)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b238dc5-7d8e-4b2d-8449-4dc212d7d227"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e71eb2d5-cd10-498d-b9eb-ae337b2f8af6"}}}], "length": {"value": 0.24769, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "60bac6f6-9fdd-4815-92c7-20ba11b7d04a", "name": "l(r:p1rdt29-p1rdt335)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b07c4a6-39a7-4521-bce7-3f1ca0ff4a66"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b238dc5-7d8e-4b2d-8449-4dc212d7d227"}}}], "length": {"value": 0.899533, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "ad61cfe0-a656-43cd-97b6-04704f1d3e5b", "name": "l(r:p1rdt335-p1rdt419)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2efeaf5-2055-4718-a064-7c5e00b7d87d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b07c4a6-39a7-4521-bce7-3f1ca0ff4a66"}}}], "length": {"value": 1.90653, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "e66e4d18-0d3a-4652-bd28-391e4e42b5ca", "name": "l(r:p1rdt419-p1rdt420)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4cf05060-0a39-49a9-a761-79fb136e2965"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81cfd2a2-295c-4b73-abba-05ffee810523"}}}], "length": {"value": 0.238058, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "e475a674-9e0e-438b-956a-b0c948b066b6", "name": "l(r:p1rdt420-p1rdt8167)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eb3d4eb-71fc-46f3-b588-d223568c411c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4cf05060-0a39-49a9-a761-79fb136e2965"}}}], "length": {"value": 0.4863970000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "cc58970e-64bc-4597-914e-37cb30e8ffc9", "name": "l(r:p1rdt8167-p1rdt8180)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c93a476-4ad5-41cd-a07b-e2ccc9ef2c3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eb3d4eb-71fc-46f3-b588-d223568c411c"}}}], "length": {"value": 0.163613, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "62e99707-ce49-47b4-a983-1959eeb7a76e", "name": "l(r:p1rdt8169-p1rdt8180)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c93a476-4ad5-41cd-a07b-e2ccc9ef2c3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6bdb2cf-9373-4d56-a5f9-cb8fa9c67e55"}}}], "length": {"value": 0.222344, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "a780ffe2-7718-4b83-b86a-e0fe3fb9d703", "name": "l(r:p1rdt8174-p1rdt8180)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "498a07ee-e12b-459a-a01f-f663a4a8428a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c93a476-4ad5-41cd-a07b-e2ccc9ef2c3b"}}}], "length": {"value": 0.527921, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "6617344b-9ba8-444d-bb97-2a58fedb9fbd", "name": "l(r:p1rdt8174-p1rdt8195)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8997dae6-8970-4762-98e9-0617375633d6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b0f9433-e0a3-458a-8687-c9cf38d0bbb3"}}}], "length": {"value": 0.115815, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "84d5b120-0d32-4f1b-a36d-b5c13c2111a5", "name": "l(r:p1rdt7757-p1rdt8195)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "081feb5c-d5d5-405e-85d4-f1dd0916fc3d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8997dae6-8970-4762-98e9-0617375633d6"}}}], "length": {"value": 0.279303, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "9ddeb1c5-3ca3-4e2d-9c80-477ec8adb6be", "name": "l(r:p1rdt5560-p1rdt7757)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68117bef-16c5-40c9-9356-76ef5c056650"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b64b7bd6-06e4-45f7-b987-efc7d09b91f8"}}}], "length": {"value": 0.322295, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "1e9bf254-9c79-4ea5-8fad-7bda32329ae5", "name": "l(r:p1rdt5560-p1rdt7757)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b64b7bd6-06e4-45f7-b987-efc7d09b91f8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "081feb5c-d5d5-405e-85d4-f1dd0916fc3d"}}}], "length": {"value": 0.349419, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "15fcd358-cd82-4f30-b9a7-7166929792fe", "name": "l(r:p1rdt5560-p1rdt5564)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8444c9ea-ff7a-4b0a-9ea6-9c18770565cb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68117bef-16c5-40c9-9356-76ef5c056650"}}}], "length": {"value": 0.08906480000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "224b5f84-1923-4354-9d26-d73c5031bd42", "name": "l(r:p1rdt5563-p1rdt5564)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad24f98d-f022-4e62-b80b-426052810759"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8444c9ea-ff7a-4b0a-9ea6-9c18770565cb"}}}], "length": {"value": 0.0604798, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "33a61b6a-9e2b-42e9-ad56-90f1398207e6", "name": "l(r:p1rdt5557-p1rdt5563)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c94489ed-4399-4dab-bab6-02b79f240f63"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fbc31b75-f942-4bae-8712-f1666d8b7f26"}}}], "length": {"value": 0.0599682, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "20b4ef91-8e73-4465-8325-4d24a3b897d5", "name": "l(r:p1rdt5557-p1rdt5565)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "efe7243f-340b-4114-be7c-f7494e78384f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bfe92e2e-285d-4c58-8e0b-a462dd73fa41"}}}], "length": {"value": 0.058444, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "6efab38c-c3e9-4312-b685-21a2d96b021e", "name": "l(r:p1rdt5561-p1rdt5565)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8bd0860f-2b3e-4c90-a571-cfc6aa649e5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bebca5d7-2d4f-4655-a965-9faafd7a8125"}}}], "length": {"value": 0.047072, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "029915e5-6ffa-4e8a-992f-299338154773", "name": "l(r:p1rdt5551-p1rdt5561)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27ab530f-a58e-4113-80f6-63f768910204"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf97a458-469e-4609-bb33-97454e7c2b68"}}}], "length": {"value": 0.0283038, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "f198382a-0a0f-4e03-9ae9-b2efa019c2ca", "name": "l(r:p1rdt5548-p1rdt5551)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d447cf8-7b2b-45f1-8084-6fe4897e1853"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ec70f12-a676-48cd-b626-34f8d7f6a5bf"}}}], "length": {"value": 0.0368985, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "a4b33341-bd57-4d7b-b4aa-f10eebfda207", "name": "l(r:p1rdt5548-p1rdt5566)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10f43169-4b4b-4dbe-8f09-af72d427d6c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23163dba-070c-435c-bb90-77be7ded002a"}}}], "length": {"value": 0.0390774, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "40c04881-ef90-4bbb-9776-4086b7596654", "name": "l(r:p1rdt5566-p1rdt5574)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf619f04-1fa5-4be7-8a76-669b79436d3e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c264e6de-a898-421d-a2fe-ce6548aa477e"}}}], "length": {"value": 0.00976661, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "3d33cc3f-87f4-4ed0-91cc-87931b9584c8", "name": "l(r:p1rdt5574-p1rdt8138)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17b633c6-214d-4428-bded-df737f50ffb6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c8fd701-7842-49c1-b630-7ae1ad49739f"}}}], "length": {"value": 0.295682, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "596de436-8b70-4b86-90d6-c950c609a1a1", "name": "l(r:p1rdt5574-p1rdt8138)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c8fd701-7842-49c1-b630-7ae1ad49739f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9906676-e9b9-4d51-b1c2-a6b6fe187faa"}}}], "length": {"value": 0.00299767, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "1e2f5da7-2523-420f-9a3f-8207dba32215", "name": "l(r:p1rdt6488-p1rdt8138)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63b2f1e6-5e15-4433-85ee-ff7bb7218b96"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "548ba541-a511-486c-876c-c841a6e482af"}}}], "length": {"value": 0.512556, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "05321a30-75f0-40c2-b4b8-86477a6638ba", "name": "l(r:p1rdt6488-p1rdt8138)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "548ba541-a511-486c-876c-c841a6e482af"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17b633c6-214d-4428-bded-df737f50ffb6"}}}], "length": {"value": 1.64392, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "0aea12b8-2186-4836-85d6-b58d4342e6b6", "name": "l(r:p1rdt6488-p1rhs7_1247)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ed5e3889-e8c8-4215-adb8-9880f8937da5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63b2f1e6-5e15-4433-85ee-ff7bb7218b96"}}}], "length": {"value": 0.640605, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "56c3525d-82f8-42be-a65c-cf7759d85f2d", "name": "l(r:p1rdt5551lv-p1rlv11506)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9dec144-ef2e-44fe-990a-c9d70b740410"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "82988650-787d-41de-bca7-4f3c08ccad15"}}}], "length": {"value": 0.0327608, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "5c2ec73d-3368-4c1c-9ef2-795598c70ec1", "name": "l(r:p1rdt5565lv-p1rlv11522)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60dc1291-a843-4abf-bfc6-ff8afc8c0b98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "176b348f-9ecf-4a82-bdf9-f2e5d5a07af7"}}}], "length": {"value": 0.05525650000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "6dacb7f0-677a-488e-9ecc-948c66479101", "name": "l(r:p1rdt5563lv-p1rlv11520)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a150dd3-61a4-4df9-90e2-6c72f80af819"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22054033-4e69-41b0-b321-a4d086d20574"}}}], "length": {"value": 0.0488534, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "96e610fa-0320-4fdb-a89f-9dc0244a5f46", "name": "l(r:p1rdt252lv-p1rlv440)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5fd6466-e740-4f06-a842-798195d62154"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a23f97bc-e7ef-4f64-9e64-314f4a4e17d8"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "3281c6b4-cd7b-405e-b82d-01608de0b3bf", "name": "padswitch(r:p1rdt5551-p1rdt5568)p1r_14627", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "514ad102-b590-4ad8-a258-2b6fa8dcbeb1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8aa126c-9b2b-4ae0-a4fc-36d4201762a0"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "6ba5defb-3101-4ef8-8d06-36719f7dad94"}}}}, {"uuid": "bf6157a4-7aa1-4ed3-b5bb-c658cc930d54", "name": "padswitch(r:p1rdt5551-p1rdt5568)p1r_14628", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64aba8d5-1dd3-4741-a8ba-26801e275ba8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c83b6ee-20fc-4ca0-a778-44735283afd5"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "b477d9d0-158a-46f2-92c2-f5870d9f433b", "name": "padswitch(r:p1rdt5548-p1rdt5577)p1r_14631", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25ee6008-ddbc-4e7b-8a57-ff38c16368a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c49b671-0b2b-43c9-bcb5-21c7b7e716ce"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "fa89ef5e-f965-457f-a553-4831f61b03c7"}}}}, {"uuid": "53cb1567-da04-45d8-9bf4-0dd5a812110d", "name": "padswitch(r:p1rdt5548-p1rdt5577)p1r_14632", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fead5749-3ba7-4ead-a604-e8adbd18f8c2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1c8b424-4509-4fd2-93e2-4fd54f6cf49a"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "3baa725a-9b39-45f8-86af-c6afda2cdf9f"}}}}, {"uuid": "f1d7385c-f334-4abd-acbc-268a6e1aa5fb", "name": "padswitch(r:p1rdt5557-p1rdt5563)p1r_14619", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cca8918c-30e6-4619-a5e0-8c0d3451f9c4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c94489ed-4399-4dab-bab6-02b79f240f63"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "2f835dde-37f4-47dd-ab96-214dd85d3c9e", "name": "padswitch(r:p1rdt5557-p1rdt5563)p1r_14620", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fbc31b75-f942-4bae-8712-f1666d8b7f26"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad24f98d-f022-4e62-b80b-426052810759"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "2419ddcd-627b-4faa-9878-65d4baf7d064"}}}}, {"uuid": "89b15386-98d4-4c15-bfd2-f82b5eea6b2a", "name": "padswitch(r:p1rdt5557-p1rdt5565)p1r_14621", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5e479d3-aae0-47b8-b707-bad1191df1e7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "efe7243f-340b-4114-be7c-f7494e78384f"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "ab2720f4-bdaa-4e93-a718-9d3398ce76a4"}}}}, {"uuid": "e2976123-591b-407f-8e3f-879e531049f6", "name": "padswitch(r:p1rdt5557-p1rdt5565)p1r_14622", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bfe92e2e-285d-4c58-8e0b-a462dd73fa41"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cca8918c-30e6-4619-a5e0-8c0d3451f9c4"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "bb21ddca-c238-4ca4-9574-9f21459c4f5a", "name": "padswitch(r:p1rdt5561-p1rdt5565)p1r_14623", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "756f6cd8-301b-4fac-b414-d72853616c6e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8bd0860f-2b3e-4c90-a571-cfc6aa649e5b"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "f58eeeef-b7c0-4252-b089-8de5183abc7c", "name": "padswitch(r:p1rdt5561-p1rdt5565)p1r_14624", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bebca5d7-2d4f-4655-a965-9faafd7a8125"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5e479d3-aae0-47b8-b707-bad1191df1e7"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "74d1d12a-803b-48eb-8e5b-0df008dc80b1", "name": "padswitch(r:p1rdt5551-p1rdt5561)p1r_14625", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f7fed4f-197e-4a79-97e5-df595377736b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27ab530f-a58e-4113-80f6-63f768910204"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "772c9103-cfcf-4ab9-ac69-f02423fe009f", "name": "padswitch(r:p1rdt5551-p1rdt5561)p1r_14626", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf97a458-469e-4609-bb33-97454e7c2b68"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "756f6cd8-301b-4fac-b414-d72853616c6e"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "278a53ba-f477-4f46-be13-b05dcff80778", "name": "padswitch(r:p1rdt5548-p1rdt5551)p1r_14629", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bf1b63d-fbce-42f8-9948-2e09bfa67409"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d447cf8-7b2b-45f1-8084-6fe4897e1853"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "c01372a2-4296-4877-a1f3-dd8c06d37f74"}}}}, {"uuid": "020e3a1d-353f-48a4-a297-a32861f78a5c", "name": "padswitch(r:p1rdt5548-p1rdt5551)p1r_14630", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ec70f12-a676-48cd-b626-34f8d7f6a5bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f7fed4f-197e-4a79-97e5-df595377736b"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "75397079-8541-4fed-9f2e-283746d35392", "name": "padswitch(r:p1rdt5548-p1rdt5566)p1r_14633", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fed9557-b170-4817-8bd8-efc3b9f7c982"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10f43169-4b4b-4dbe-8f09-af72d427d6c7"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4900e609-ebb1-44db-852b-602449095f15"}}}}, {"uuid": "9fbe0ee9-ae7d-4233-af14-ea12e83dc720", "name": "padswitch(r:p1rdt5548-p1rdt5566)p1r_14634", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23163dba-070c-435c-bb90-77be7ded002a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bf1b63d-fbce-42f8-9948-2e09bfa67409"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "d4fd35e4-7997-430a-854e-c1cdde29c7cc", "name": "padswitch(r:p1rdt5566-p1rdt5574)p1r_14635", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9906676-e9b9-4d51-b1c2-a6b6fe187faa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf619f04-1fa5-4be7-8a76-669b79436d3e"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "f3caa620-fb40-4165-abf4-46f624ae5a85", "name": "padswitch(r:p1rdt5566-p1rdt5574)p1r_14636", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c264e6de-a898-421d-a2fe-ce6548aa477e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fed9557-b170-4817-8bd8-efc3b9f7c982"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "8e708baa-3ad1-4899-8c29-fc507efdc551", "name": "fuse(r:p1rdt31-p1rdt38)p1r_16627", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7c543753-fa26-41df-b7a6-3664395c0d45"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "668d32be-c07a-4387-86a5-e9754af11e9c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "5ef87d33-a0f9-4b56-9457-0d7cb679088c", "name": "fuse(r:p1rdt210-p1rdt44)p1r_16628", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d9ee2ff-e2bc-4d76-b173-5ba5cc48c9b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1be5e34-ad5e-4c78-8067-8e0194c661a4"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "251fa307-5e1e-4ffa-a841-ff333862a949", "name": "fuse(r:p1rdt259-p1rdt44)p1r_16629", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d9ee2ff-e2bc-4d76-b173-5ba5cc48c9b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0b5743e-c3fd-49c7-879e-9be7d00c480f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "105be1c0-9f28-4814-ab44-267fbb4f0af7", "name": "fuse(r:p1rdt58-p1rdt69)p1r_16631", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9396562e-4f87-4e04-b248-502b851fe19e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7238345a-1fc7-4f3f-bc8b-88cf7582c75c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "c452d159-ea97-4544-ab4a-93d0e7ce8631", "name": "fuse(r:p1rdt37-p1rdt80)p1r_16632", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b03f8e29-a5b2-4bed-b68c-219276674b6a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a2b529c9-4695-42f3-a0e3-69bbb34ff285"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "da4bb223-04fc-4e5d-b2db-f16866497bb6", "name": "fuse(r:p1rdt74-p1rdt85)p1r_16633", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fc415bc-f457-4e9f-bbd4-783a71b67ad6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b82a9a2-b1d1-44eb-a451-946643ef613d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "58221277-9ee4-4071-8967-a1d0bdcbbf92", "name": "fuse(r:p1rdt150-p1rdt71)p1r_16651", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12451cbc-eb14-4814-b274-12eb2241c78a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eab6b8c5-ee7a-4779-b5eb-5205dbe5253c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "74603d74-9f0d-4842-b655-cfdee489dad0", "name": "fuse(r:p1rdt251-p1rdt254)p1r_16679", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b801037a-e1bb-4c5c-8d18-ed285c8c1d3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9c899bc-796a-4e92-88db-6aa11f8777cb"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "25c5e70e-dd57-4030-b431-72effcf942e6", "name": "fuse(r:p1rdt252-p1rdt385)p1r_16680", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69b2ee46-ab5f-48c8-a26b-170ed2b57fcb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22179eaa-fd19-4619-8b31-52bcb36ec683"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770"}}}}, {"uuid": "af70abad-e2d2-466e-ac06-19c43f7ce09a", "name": "fuse(r:p1rdt261-p1rdt277)p1r_16684", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "add5e39f-f02e-4a61-a156-d5721cec25d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bbe3ac37-aca0-47fd-ac5d-be390cad10ab"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "5cb48d44-c6a0-4b2a-ae95-38168b6ed9e6", "name": "fuse(r:p1rdt279-p1rdt89)p1r_16685", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "153bb615-5ee5-4eec-bcf7-94ea0098aeb6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "232adbbb-2715-44be-8db5-ee062ebf4e46"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "ae0efabc-30d4-4b0b-87f1-14de9ef567fc", "name": "fuse(r:p1rdt335-p1rdt376)p1r_16692", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b07c4a6-39a7-4521-bce7-3f1ca0ff4a66"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0de112ae-d04a-4673-98af-0699e4890429"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "804bf703-8117-4553-b55c-90b0e0138f28", "name": "fuse(r:p1rdt415-p1rdt419)p1r_16706", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81cfd2a2-295c-4b73-abba-05ffee810523"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19116f3c-29ae-4819-ba72-dd0f8afa5078"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "cc0d8f4f-cb74-41bf-915f-657a26c4dce0", "name": "fuse(r:p1rdt456-p1rdt465)p1r_16710", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a94f7afe-e8b0-4b24-8196-6b05e98c3830"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b092ee09-4c5e-46b5-8ec2-51f99254c220"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "9d67edf0-3af2-46a6-b5a7-af017e3a23be", "name": "fuse(r:p1rdt458-p1rdt468)p1r_16711", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a180b972-cf0e-4a2e-9bcf-a0ad90bb3d83"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04fc215c-7f3e-45e1-a49c-727b0fcdae93"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770"}}}}, {"uuid": "e812226f-f357-4c18-96e8-9949554baf21", "name": "fuse(r:p1rdt468-p1rdt474)p1r_16712", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a180b972-cf0e-4a2e-9bcf-a0ad90bb3d83"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5814195b-dd60-4a1e-9af6-b9b84fa4c0c7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "9860b763-07dc-4e8d-8870-1afd3a7f37e2", "name": "fuse(r:p1rdt466-p1rdt478)p1r_16713", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eba354c-f4bf-4c49-a8ad-998ab9489e5a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64ba6716-89f9-49a4-9793-ba80ae41bcd0"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "da8c1709-80de-4678-8309-269d2f230e38", "name": "fuse(r:p1rdt482-p1rdt485)p1r_16714", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "445f61a4-8045-4558-a3c1-bb44336737ec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4064b6c-40b4-418b-95ab-4f9bb0363b14"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770"}}}}, {"uuid": "c04ff227-206a-442c-a266-475342372f3b", "name": "fuse(r:p1rdt483-p1rdt485)p1r_16715", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "445f61a4-8045-4558-a3c1-bb44336737ec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d899b807-b194-4f65-bad5-a39e8bc61906"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "2b29065b-ab29-4a29-992e-6fa020baefb0", "name": "fuse(r:p1rdt5548-p1rdt5577)p1r_17662", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bf1b63d-fbce-42f8-9948-2e09bfa67409"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25ee6008-ddbc-4e7b-8a57-ff38c16368a2"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "73f75b89-55b4-4a16-9fa1-8771daf3d5be"}}}}, {"uuid": "ac5b78b4-1db7-4049-8ac8-190123ae26d7", "name": "fuse(r:p1rdt5551-p1rdt5568)p1r_17664", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f7fed4f-197e-4a79-97e5-df595377736b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "514ad102-b590-4ad8-a258-2b6fa8dcbeb1"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "861d64ae-aba6-4135-a3ca-f177438722a2"}}}}, {"uuid": "6de2926c-cdd7-4dbe-954c-e5e73d440add", "name": "fuse(r:p1rdt5560-p1rdt9055)p1r_17668", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68117bef-16c5-40c9-9356-76ef5c056650"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30adfcd5-405b-47ea-be54-55c5a47c835f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "b77c5f87-769c-4ad7-b6b5-9fbe48d98a9e", "name": "fuse(r:p1rdt6488-p1rdt7300)p1r_17851", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63b2f1e6-5e15-4433-85ee-ff7bb7218b96"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47f8ed28-4bff-47d9-8ffe-4509e9c5b7fc"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "3228c925-05c0-4c64-b9fc-c95e6716280b", "name": "fuse(r:p1rdt7757-p1rdt7795)p1r_18078", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "081feb5c-d5d5-405e-85d4-f1dd0916fc3d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0cd22d3e-1e2a-4a99-9967-b9df95837915"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "5bbe221f-b4a5-48b0-807d-e4b8038385f1", "name": "fuse(r:p1rdt8111-p1rdt8138)p1r_18142", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17b633c6-214d-4428-bded-df737f50ffb6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9929e0d4-3e33-4f5f-b718-6a629cc52242"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "1f205dc8-03e2-4638-9e38-39bda752ee14", "name": "fuse(r:p1rdt5098-p1rdt8169)p1r_18150", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6bdb2cf-9373-4d56-a5f9-cb8fa9c67e55"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb3d775d-8d92-498b-989c-387278ec8e9e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "7a9f88b5-9266-4dc3-94d4-4b1fd3397487", "name": "fuse(r:p1rdt6266-p1rdt8174)p1r_18152", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b0f9433-e0a3-458a-8687-c9cf38d0bbb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d07105ef-1ba3-4775-aeb4-650b5ea8736e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770"}}}}, {"uuid": "d30f8def-15f6-47be-ab3f-8814ccb37121", "name": "fuse(r:p1rdt8180-p1rdt8201)p1r_18154", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c93a476-4ad5-41cd-a07b-e2ccc9ef2c3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63928702-c44a-4e83-9cca-7ce77bdbd2b3"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "6b0a6718-181b-4c20-9dc3-45257942ad04", "name": "goab_disswitch(r:p1rdt335-p1rdt419)p1r_20734", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81cfd2a2-295c-4b73-abba-05ffee810523"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2efeaf5-2055-4718-a064-7c5e00b7d87d"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "2419ddcd-627b-4faa-9878-65d4baf7d064"}}}}, {"uuid": "a8dbe250-f335-4a33-8967-d9144ec88082", "name": "goab_disswitch(r:p1rdt276-p1rdt279)p1r_20887", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "186ffdfe-2346-4218-bd6b-b813ea6b3b62"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7140d97e-416e-47ec-9f86-46ad6f9abece"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "466a17b2-2a29-4496-8652-610b208f7f1b", "name": "disswitch(r:p1rdt181-p1rdt297)p1r_20911", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d32493ec-06be-48ef-959e-779c79c507a3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2fddf29e-6eef-4c60-ad8b-4580440973b3"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "7351fbec-02bf-4cbf-aea9-09a23aa2a9b8", "name": "goab_disswitch(r:p1rdt237-p1rdt276)p1r_20993", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8c8b8f8-7a41-4d16-b509-2d7c7af9509d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3ca9bee-26b0-4ef4-8555-6494ffdd6a17"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "2a5a5f0e-3473-4d3f-ac60-0c576781cacc", "name": "disswitch(r:p1rdt16790-p1rdt487)p1r_21007", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfb0d992-ab18-4f73-933e-a01ce73ef3b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d53ff9fd-2b16-4026-88fa-2c112d4949c5"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "e7ce538c-39a2-4585-8cd8-85cefb5001b7", "name": "disswitch(r:p1rdt16604-p1rdt257)p1r_21113", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fb307f7-3690-4931-999a-4daab4d8c9e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ef71bd7-4c82-4296-a6ac-64516ffe96c5"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "2d897f3c-bcb4-45c3-8f45-79a7882361d3", "name": "disswitch(r:p1rdt270-p1rdt298)p1r_21212", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a468f13-c61f-4c01-aa27-c75fb02030e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2c76250-d7ea-4da4-8008-dac1a579e974"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "05155e19-68bb-4b06-a90e-2af3c0f63384", "name": "recloser_disswitch(r:p1rdt8174-p1rdt8180)p1r_21285", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b0f9433-e0a3-458a-8687-c9cf38d0bbb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "498a07ee-e12b-459a-a01f-f663a4a8428a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "b8590a64-3624-43d1-8279-40a7928d98a9"}}}}, {"uuid": "4d2272d5-4fc9-48e9-84db-9b8f3f9f327a", "name": "disswitch(r:p1rdt383-p1rdt7300)p1r_21354", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05f14a3e-053e-4b65-b962-da7804b9e2c1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9240d01-bf5d-41ed-8c53-c1f04af1a236"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "c57b3c83-e7ed-4283-84e7-230a16052433", "name": "l(r:p1rdt383-p1rdt7300)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ac1506-77e9-4b90-ad3d-18be099063a9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16ace27f-f5fa-4fd1-840e-8cae55dbe1b2"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "40a26197-da2a-4e22-a50a-3922efd7762c"}}}}, {"uuid": "dfe3055b-071a-4b16-a1f5-8817c9563e7c", "name": "l(r:p1rdt383-p1rdt7300)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16ace27f-f5fa-4fd1-840e-8cae55dbe1b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d49257c8-f8eb-4024-9c02-461d18cdd3d5"}}}], "length": {"value": 2.9030580000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4bd7147d-d66a-4be7-afc9-1ac8815e7212", "name": "l(r:p1rdt181-p1rdt66)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24681ab1-3904-4509-85e6-d9bb1dba4c8e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6b5c947-b0c5-4e20-bd74-bf847bdacd30"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "40a26197-da2a-4e22-a50a-3922efd7762c"}}}}, {"uuid": "239c598c-522f-4509-8755-3e56148c7ce9", "name": "l(r:p1rdt181-p1rdt66)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6b5c947-b0c5-4e20-bd74-bf847bdacd30"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99615f32-0614-4c23-a1e1-b3e8e5688cce"}}}], "length": {"value": 1.8166859999999998, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c0340108-7ee4-45aa-91e0-afcce5d859a4", "name": "l(r:p1rdt181-p1rdt297)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d87f56c0-0a3f-4a94-8f60-1ece461290d0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "71abd5f1-ca61-4754-a2ef-7b5d4e635f99"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "40a26197-da2a-4e22-a50a-3922efd7762c"}}}}, {"uuid": "ef009cf0-e83d-4133-b85e-647ec7c82b7f", "name": "l(r:p1rdt181-p1rdt297)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "71abd5f1-ca61-4754-a2ef-7b5d4e635f99"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79d0fee6-369b-4f95-a2d2-cd05232652e3"}}}], "length": {"value": 4.570002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d448bbc0-7a67-4bb2-94aa-7d605ebab0df", "name": "l(r:p1rdt270-p1rdt298)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac7c613f-190c-493e-8e89-3ef48e8efdb9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0fad7ee-b65c-460c-94ca-fe9546a5b140"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "40a26197-da2a-4e22-a50a-3922efd7762c"}}}}, {"uuid": "c9722f40-a6c0-4a05-a737-bd2ff278c33d", "name": "l(r:p1rdt270-p1rdt298)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0fad7ee-b65c-460c-94ca-fe9546a5b140"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7eca59ac-01f1-40d7-a0ec-51f355285e01"}}}], "length": {"value": 2.6162099999999997, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3e4e6114-3df1-4523-b480-028a3f01d2e4", "name": "l(r:p1rdt16604-p1rdt257)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "282d8a89-8b14-476b-9e55-b310d8b9396d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8064f1d-11b7-4913-8344-175c1388be3e"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "40a26197-da2a-4e22-a50a-3922efd7762c"}}}}, {"uuid": "642f1479-fef3-4ab0-869d-276f7aaeca18", "name": "l(r:p1rdt16604-p1rdt257)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8064f1d-11b7-4913-8344-175c1388be3e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98a946e8-3c8a-49ec-be8a-5610c7fc596c"}}}], "length": {"value": 2.362599, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a7288c5c-c39d-4983-bd6a-e028ec000d5f", "name": "l(r:p1rdt7711-p1rhs7_1247)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1548dd91-bc3d-4a2c-903f-48e11159c558"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2131350-dc34-4d8d-8c9f-c29e25bc654c"}}}], "length": {"value": 2.34083, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "dfffd734-a5e2-42da-a25d-4360affa98b0", "name": "l(r:p1rdt7711lv-p1rlv16411)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64b60527-0853-4973-8d7a-78ba5e377799"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ed6276c-a57b-40be-a1f1-34aaaba0ac28"}}}], "length": {"value": 0.0104732, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "4eb8fe85-248b-4062-b84b-bd291bf09b51", "name": "l(r:p1rdt7711lv-p1rlv20414)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64b60527-0853-4973-8d7a-78ba5e377799"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0a92e79-0ca2-4a10-9050-9e8d7442b019"}}}], "length": {"value": 0.0104732, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "9e9dcf4a-3b83-4e15-a8d0-6f5351cdc13c", "name": "l(r:p1rdt8473lv-p1rlv18169)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "439728c5-fee5-4dfa-9894-261ba6c40e95"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c1eac45-623a-4f0a-874d-a4b56a8e2ea7"}}}], "length": {"value": 0.0202596, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "8285453f-abc7-420b-93ac-60cb9aaef09e", "name": "l(r:p1rdt8473lv-p1rlv18194)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "439728c5-fee5-4dfa-9894-261ba6c40e95"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "949f4cce-f321-4bf0-830b-489edc9964c7"}}}], "length": {"value": 0.0202596, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "d9d639df-5b76-47fe-9b75-d4e7ec515ae1", "name": "l(r:p1rdt6028lv-p1rlv12518)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35f6f747-811d-4fe2-a9c7-991248572c74"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72f659b6-d302-4887-a2f6-1a477ad3324c"}}}], "length": {"value": 0.0196521, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "9475313a-299b-446b-91ed-94cdb2d345d5", "name": "l(r:p1rdt6028lv-p1rlv12528)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35f6f747-811d-4fe2-a9c7-991248572c74"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9660b80-0fce-4be4-b541-743d5811133c"}}}], "length": {"value": 0.0563852, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "ffe84a3b-76b8-4dec-9c29-0084691588fe", "name": "l(r:p1rdt6028lv-p1rlv12534)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35f6f747-811d-4fe2-a9c7-991248572c74"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8796d817-aad6-4d22-b3d4-baf8a686c9df"}}}], "length": {"value": 0.00754144, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "4a309f30-e352-4599-9dee-ffca476a4e9e", "name": "l(r:p1rdt6028lv-p1rlv12536)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35f6f747-811d-4fe2-a9c7-991248572c74"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e89452f3-ce44-46d3-a259-f66044e01c2c"}}}], "length": {"value": 0.0368264, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "7399e1c5-5e83-4fa9-a9b6-9d3a1a693f55", "name": "l(r:p1rdt9478lv-p1rlv20501)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddf38626-1223-429f-a903-98f1c975020b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cebe1b53-cca6-4bd4-a9f0-616ffb9750b3"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "f3e4b646-2702-4787-930b-a42a5c45d53f", "name": "l(r:p1rdt6232lv-p1rlv12985)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e2630e1-a215-4740-9327-fa004e89863d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df3aae83-f4b0-4db2-9301-dff1664ac23e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "8e5baa4c-dd50-4330-b9cb-45f46ac26d1c", "name": "l(r:p1rdt6232-p1rdt9478)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c49b6e87-5834-4e7e-a64c-b4ec0f7d4995"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b59ad93a-cca2-4a77-8515-a645ddd2a320"}}}], "length": {"value": 0.08088850000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d287939e-187e-44ce-adc8-c5deb1efe035", "name": "l(r:p1rdt6028-p1rdt9478)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e39cb1db-d6a6-4b6c-bc73-920e0c34c292"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f77960bf-f017-400c-b505-16e7c2e90fe7"}}}], "length": {"value": 0.29557, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "38175911-904e-413e-b9f3-ba12b0d54714", "name": "l(r:p1rdt6028-p1rdt8473)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3a83211-0829-4e2c-b618-3f1fcaba3e87"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e39cb1db-d6a6-4b6c-bc73-920e0c34c292"}}}], "length": {"value": 0.233087, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "24ba44ff-6a1e-424c-802a-5e685da39576", "name": "l(r:p1rdt7711-p1rdt8473)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2131350-dc34-4d8d-8c9f-c29e25bc654c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3a83211-0829-4e2c-b618-3f1fcaba3e87"}}}], "length": {"value": 0.502313, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "c94a5bb4-b7c5-4f79-9cf8-1375d4c8b6cb", "name": "l(r:p1rdt8493lv-p1rlv18201)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c330731a-fd2c-40c7-8fce-94f7e17cf6d9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ead37cb8-af1e-4a46-9466-6ff298b7f8b7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "248b171b-5e13-4070-b36a-12d088475c3c", "name": "l(r:p1rdt7711-p1rdt8493)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2131350-dc34-4d8d-8c9f-c29e25bc654c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfb41891-7063-44b8-9286-1fe763e49924"}}}], "length": {"value": 0.719466, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "5cd18c4b-7e66-4567-99aa-adbf0e339973", "name": "l(r:p1rdt6028-p1rdt9478)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f77960bf-f017-400c-b505-16e7c2e90fe7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "409a29cf-ddd5-4031-92ca-db6cd2410704"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "937849ae-e1ac-40fe-b786-984a89a281f3", "name": "l(r:p1rdt6028-p1rdt9478)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "409a29cf-ddd5-4031-92ca-db6cd2410704"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c49b6e87-5834-4e7e-a64c-b4ec0f7d4995"}}}], "length": {"value": 2.66913, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "87fc45c2-660b-4f99-b658-eb377ae27502", "name": "l(r:p1rdt93lv-p1rlv183)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0921e58d-1ada-4556-8b01-8f22d3bf4ee2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3df778b4-e60b-4e17-b24b-67742d090f42"}}}], "length": {"value": 0.062918, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0c7ce66f-32b1-4f29-8c1b-ff8cb7cbe189", "name": "l(r:p1rdt93lv-p1rlv204)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0921e58d-1ada-4556-8b01-8f22d3bf4ee2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d663fcdc-6c67-4bc9-99ed-12439f75804f"}}}], "length": {"value": 0.0275441, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c67015ab-e194-4fac-82b0-87878c41d658", "name": "l(r:p1rdm198-p1rlv206)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2be21180-bfa8-4cd1-a3c5-68602896d657"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90aa0d14-285a-4468-bbde-8d76f65b1780"}}}], "length": {"value": 0.047457, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "04bb6407-6835-4d3c-8629-76af3bf1c2ae", "name": "l(r:p1rdm198-p1rdt93lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0921e58d-1ada-4556-8b01-8f22d3bf4ee2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2be21180-bfa8-4cd1-a3c5-68602896d657"}}}], "length": {"value": 0.0116535, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8364cd7f-2820-4bcf-bb37-67dadafb4bb2", "name": "l(r:p1rdm199-p1rlv207)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a70fd02-3816-451f-a509-2ad767068eb4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6627102c-4524-4e69-bb4d-5b93226df412"}}}], "length": {"value": 0.0665106, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a2920457-6a3e-4fb5-95d3-b5dfbe0a7490", "name": "l(r:p1rdm196-p1rlv184)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6065e92f-dd89-4aeb-94af-173d81a49df1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42ca8327-5dcc-415a-820c-ef6ec038b3d8"}}}], "length": {"value": 0.0719696, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "382af86a-c688-4778-b6b8-2005858ec39b", "name": "l(r:p1rdm196-p1rdm199)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a70fd02-3816-451f-a509-2ad767068eb4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6065e92f-dd89-4aeb-94af-173d81a49df1"}}}], "length": {"value": 0.0157359, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "796dcb0c-914a-4476-8a88-6a5c6023faca", "name": "l(r:p1rdm199-p1rdt93lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0921e58d-1ada-4556-8b01-8f22d3bf4ee2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a70fd02-3816-451f-a509-2ad767068eb4"}}}], "length": {"value": 0.00889089, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "2d347746-0969-4a8a-b986-c40ef4f4c015"}}}}, {"uuid": "3a950c68-44a5-458a-ae67-40de974d8047", "name": "l(r:p1rdt99lv-p1rlv190)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef6be92d-5d1b-40e2-a2c2-9d0c1f0bf596"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33b6400e-c84e-43cf-b254-99f946e5a308"}}}], "length": {"value": 0.040055, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4ab7dd7f-8f59-4338-807a-6a59fdb9d2c6", "name": "l(r:p1rdt99lv-p1rlv202)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef6be92d-5d1b-40e2-a2c2-9d0c1f0bf596"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "de2366e4-30da-429a-82b9-c0ef27eeab47"}}}], "length": {"value": 0.040055, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c79aa124-41f0-475e-b27b-c7974a25b335", "name": "l(r:p1rdt101lv-p1rlv193)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1277a701-9fbd-4853-a809-962475e016c4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84223c1b-69e4-4ebc-8274-8706bb412780"}}}], "length": {"value": 0.060663, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "5ef15021-e9f7-4934-ad47-fa982ef83d7f", "name": "l(r:p1rdt108lv-p1rlv212)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3aa8d6f2-8d84-42d6-8e7b-89e3b1efa03c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a982feac-5730-4fe0-a1b8-25c06b36e3b0"}}}], "length": {"value": 0.0158014, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9ba90c4e-cda5-4a96-8214-9766f675c80a", "name": "l(r:p1rdt6121lv-p1rlv12687)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "448cc5e0-391f-4a6b-8199-25cef4593edf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "163c3824-6847-4b94-9e81-08f15f4667a1"}}}], "length": {"value": 0.0852199, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b466ad0c-36a2-4215-b99e-1e2e9147cca4", "name": "l(r:p1rdt6123lv-p1rlv12713)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e81ba94-5857-42e4-aeee-58542cef0fb6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff16aad0-98c1-4563-a844-e0ce909c1a79"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "6db4a71c-d59e-49fb-b9ee-3aebd949e6ab", "name": "l(r:p1rdt8017lv-p1rlv17006)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8428de0e-4b06-4f19-bffb-5fed32f96f67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b53edd15-5a3e-4b7a-97c4-046582bb4801"}}}], "length": {"value": 0.0396626, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6f7024dc-43c4-4070-b610-d88c786d2e4b", "name": "l(r:p1rdt8043lv-p1rlv17103)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a367e687-b29a-44b4-a943-7b94762e549e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ff9eb4c-2523-48e0-8490-619d26b9cca4"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b797d3a2-ee2f-4f54-b06e-9fa0e6dbb21e", "name": "l(r:p1rdt8065lv-p1rlv17155)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8bb025c5-31eb-4771-b433-e1dcad03b3ed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3c6c52e-cf93-467a-a303-94b96b33a3da"}}}], "length": {"value": 0.00641649, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6f467e58-32b6-4e07-9a32-2fcae57445d9", "name": "l(r:p1rdm17752-p1rlv17164)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62e77e46-bf33-474f-907b-81d36aae8975"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "041caa30-2985-44ca-8013-e11a9bda7dff"}}}], "length": {"value": 0.0585553, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "aa9f431f-8d45-4d2f-b3ef-6ed973e7fdfe", "name": "l(r:p1rdm17752-p1rdt8068lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd01eed6-0e70-42e7-ac29-4bfd2f70366a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62e77e46-bf33-474f-907b-81d36aae8975"}}}], "length": {"value": 0.00975828, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "46cadd28-41d2-4b33-b229-53938b6526d2", "name": "l(r:p1rdm17753-p1rlv17199)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "46b5c5bc-6738-4520-b98c-32bd43f4c91c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5768eaca-abe3-4347-af78-02b50ec6f2a9"}}}], "length": {"value": 0.07246250000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "815be72a-4590-47bf-b23a-93bee76e3ffc", "name": "l(r:p1rdm17753-p1rdt8068lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd01eed6-0e70-42e7-ac29-4bfd2f70366a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "46b5c5bc-6738-4520-b98c-32bd43f4c91c"}}}], "length": {"value": 0.00869985, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "07d3ecbb-c8d8-4498-b7de-9dede233fa9a", "name": "l(r:p1rdt8070lv-p1rlv17167)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0bcd460-ccf2-42ee-83c6-bada397ab4d6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b4e44ab-e644-4e48-b1b2-82dc15d38d17"}}}], "length": {"value": 0.0455049, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e1c383ad-81e0-4ef4-8d77-433f8c2369fc", "name": "l(r:p1rdt8190lv-p1rlv17376)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f21f4e99-8877-4bb0-9956-9240bc6db3d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c9970ae-e914-407d-8222-12c08638a854"}}}], "length": {"value": 0.0538062, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "5c4315d9-3bd5-4e8d-8f59-4e452cc39791", "name": "l(r:p1rdt8204lv-p1rlv17402)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d12bf6fb-8dac-4729-bcda-1ee61c63f6e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc7fa312-1baf-4f23-925f-a281071183a6"}}}], "length": {"value": 0.020109400000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "930a8c5d-1c84-449e-aeb0-b249e1fc8fbe", "name": "l(r:p1rdt8208lv-p1rlv17413)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ecf11723-eb6d-423c-ac0c-85fa2d1ba846"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f147f7e5-33e8-430b-9822-715e772debb3"}}}], "length": {"value": 0.058289, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "49a21a95-e38f-4a69-be2a-b889705a3a47", "name": "l(r:p1rdt8578lv-p1rlv18362)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1a593e3-4735-47d2-b893-dd2d07c3c47c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a28b095-45f5-43ec-983b-c1de596d4cb5"}}}], "length": {"value": 0.0205693, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "dc98da20-4587-480f-8cb1-3a411d9e0658", "name": "l(r:p1rdt8578lv-p1rlv18364)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1a593e3-4735-47d2-b893-dd2d07c3c47c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d1c3d0a-9def-4516-8429-386f1d70f506"}}}], "length": {"value": 0.0370574, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f8487d44-54da-4eec-870f-b9de934b0640", "name": "l(r:p1rdt8578lv-p1rlv18367)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1a593e3-4735-47d2-b893-dd2d07c3c47c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "408c825d-17ac-4aea-9fc7-fff420657fc7"}}}], "length": {"value": 0.018828, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cce59d54-5697-4708-a924-410992705356", "name": "l(r:p1rdt8583lv-p1rlv18370)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "134bac3d-5b7e-48d7-950e-01e5b7d43852"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905e171c-13d7-4f8d-b88a-7501b2327d81"}}}], "length": {"value": 0.0934621, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "72285fbb-7891-4916-bd04-d67ce9189e58", "name": "l(r:p1rdt8584lv-p1rlv18371)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8ba1042-fcfd-47a8-aa0f-8b13618d3212"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58792e8c-3ad9-45bb-ac47-01983cca2a2b"}}}], "length": {"value": 0.0568796, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0ed44728-cace-4d39-8182-28659b1113a8", "name": "l(r:p1rdt10491lv-p1rlv22745)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8f14e6e-ee96-4ae9-86ba-4a07cf103b65"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a86348e4-7573-4903-b223-90155579923e"}}}], "length": {"value": 0.00860717, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "69f39247-71ec-4488-a1b5-9cd9caff8cb6", "name": "l(r:p1rdm23269-p1rlv22758)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee8b6bab-9edd-4250-b57b-3a76b432fb54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db05b7f0-d2a8-4876-876e-ef0e9b469580"}}}], "length": {"value": 0.0077383, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "545f2993-60ea-4122-8ac8-124799e17c31", "name": "l(r:p1rdm23269-p1rdt10491lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8f14e6e-ee96-4ae9-86ba-4a07cf103b65"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee8b6bab-9edd-4250-b57b-3a76b432fb54"}}}], "length": {"value": 0.017970700000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a19ed19d-f5f9-42c8-b5d1-520605196747", "name": "l(r:p1rdt8065-p1rdt8070)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473520c7-0098-4bc2-a46f-07efd6c3759c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "862f3566-9443-4b82-8f05-c994581e131a"}}}], "length": {"value": 0.11506000000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f82ea167-4bb5-4acb-8736-ba3098b01929", "name": "l(r:p1rdt8068-p1rdt8070)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473520c7-0098-4bc2-a46f-07efd6c3759c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f5fbb8b-0c32-4aa7-acaf-7ea2b5e56505"}}}], "length": {"value": 0.0454225, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "2cfe2726-ca82-4184-af38-1db485d3622d", "name": "l(r:p1rdt8043-p1rdt8070)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "691c1909-3b71-4e07-abf0-95aaabfa23bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbafbe81-1649-4bae-b9af-c4b1757392f0"}}}], "length": {"value": 1.20903, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c939ca25-23bc-45e6-afb1-34c98b300b8d", "name": "l(r:p1rdt8043-p1rdt8070)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbafbe81-1649-4bae-b9af-c4b1757392f0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473520c7-0098-4bc2-a46f-07efd6c3759c"}}}], "length": {"value": 0.714168, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1a6283f9-eca9-4da3-9aec-868e430d702b", "name": "l(r:p1rdt10491-p1rdt8043)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "691c1909-3b71-4e07-abf0-95aaabfa23bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ca19324f-0855-4633-be68-b16c872e196d"}}}], "length": {"value": 0.143178, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f42fe8fc-80ec-4c50-a106-91fa534f3edc", "name": "l(r:p1rdt10491-p1rdt8043)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ca19324f-0855-4633-be68-b16c872e196d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4737e613-8cf5-45d7-a3f5-71af051ece4c"}}}], "length": {"value": 1.81692, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d5dee6d5-a427-4319-b9b9-44bc16841f5f", "name": "l(r:p1rdt8017-p1rdt8043)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6378abd-969e-4ec8-93eb-2cc39cdb18eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "feda8d99-6fae-4c6e-bf52-f87894687da5"}}}], "length": {"value": 0.18707900000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ccb7a0ac-a308-4217-afd4-043b2b325c6b", "name": "l(r:p1rdt8017-p1rdt8043)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "feda8d99-6fae-4c6e-bf52-f87894687da5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "691c1909-3b71-4e07-abf0-95aaabfa23bb"}}}], "length": {"value": 0.534353, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "db26ea21-d0ad-492d-88d3-62e4b8b52675", "name": "l(r:p1rdt101-p1rdt8017)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a09cdbca-4e7b-4d9a-b479-515074964171"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1aeba4b-536e-4067-a7a5-627470ae0711"}}}], "length": {"value": 0.331129, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b5b98590-9dc7-4cd0-a4d2-066a47550a6e", "name": "l(r:p1rdt101-p1rdt8017)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1aeba4b-536e-4067-a7a5-627470ae0711"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c1a4365-a594-48be-b138-aa6935c34481"}}}], "length": {"value": 2.00417, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e7f6e4db-47b4-40d6-b0c7-8836d796842d", "name": "l(r:p1rdt101-p1rdt8017)_s2", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c1a4365-a594-48be-b138-aa6935c34481"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6378abd-969e-4ec8-93eb-2cc39cdb18eb"}}}], "length": {"value": 0.0990287, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "358ea440-8af5-49f3-a7e5-bf3ece06fe47", "name": "l(r:p1rdt101-p1rdt108)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e61ce952-a643-45aa-a466-8aa15ecceb48"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d8e5d83-cd9c-4527-9eef-6219c98dfe93"}}}], "length": {"value": 0.0862881, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e86bf583-73fe-41bb-bdae-274719a15774", "name": "l(r:p1rdt108-p1rdt93)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4f100ee-0152-4e27-bf0e-2c7dea1537ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e61ce952-a643-45aa-a466-8aa15ecceb48"}}}], "length": {"value": 0.0403624, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "73cf1758-bfb1-404d-80ef-ae8deceb880c", "name": "l(r:p1rdt8204-p1rdt8208)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e2b4d77-2388-4897-86fe-06409fa9d222"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa2342e6-2d40-424a-830c-a84af4632b6e"}}}], "length": {"value": 0.29712, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bc1ca79c-0481-4721-87d4-46e512a8cdcd", "name": "l(r:p1rdt8190-p1rdt8208)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a761aef-a766-40e2-b8d7-e5a918cece18"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e2b4d77-2388-4897-86fe-06409fa9d222"}}}], "length": {"value": 0.056324900000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e3ede097-3f6e-463a-8da9-8632b7c482b3", "name": "l(r:p1rdt8190-p1rdt99)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b860d5c-43e4-429e-b945-378020e3f926"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6be75535-8c32-47ea-bad5-986daaed0921"}}}], "length": {"value": 1.66165, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "700118f2-7a55-4195-9574-c5978603f45e", "name": "l(r:p1rdt8190-p1rdt99)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6be75535-8c32-47ea-bad5-986daaed0921"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a761aef-a766-40e2-b8d7-e5a918cece18"}}}], "length": {"value": 0.18014, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1b462af5-d08e-4ef0-a01e-73536834674c", "name": "l(r:p1rdt6121-p1rdt6123)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddf8f344-dcca-418d-850e-745f18d29660"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17f807ba-6ad6-4fd9-9dd0-2c0bacea5b24"}}}], "length": {"value": 0.192685, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d1b3aa3f-5f80-4d51-a2cd-0171c797aabb", "name": "l(r:p1rdt8583-p1rdt8584)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0747505-3381-4df0-a86e-3859acac8496"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b601580-3091-4d8c-9718-1367c7ed385f"}}}], "length": {"value": 0.11744700000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5a01c8c2-afff-4ba5-957f-a2692170814e", "name": "l(r:p1rdt93-p1rdt99)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "092a9d51-a39c-4c05-905e-93fb1ae96ba2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3d15ce6-878d-4dd5-bb33-5a0f6c11dded"}}}], "length": {"value": 0.141059, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "9a0a937c-8779-4945-b7a2-5c75476497cb", "name": "l(r:p1rdt93-p1rdt99)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3d15ce6-878d-4dd5-bb33-5a0f6c11dded"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "900d49ce-4834-4f99-8d74-a5e9d2f63ea0"}}}], "length": {"value": 0.0271696, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "bcaefac9-1c3b-4558-a4c8-277deff0ddcc", "name": "l(r:p1rdt6121-p1rdt99)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2390c014-d418-4d63-8438-529a036487db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49c9e6df-3490-4df1-88a0-8a83ca6cdd1e"}}}], "length": {"value": 0.978472, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "0aff09d1-b70c-477f-bd3b-0d2d1a8a6a03", "name": "l(r:p1rdt6121-p1rdt99)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49c9e6df-3490-4df1-88a0-8a83ca6cdd1e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "092a9d51-a39c-4c05-905e-93fb1ae96ba2"}}}], "length": {"value": 0.2822120000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "ec452fcc-6021-44bc-9ae1-4cb5035bb351", "name": "l(r:p1rdt6121-p1rdt8578)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb866499-9e9c-4394-bd76-d4320ba4934b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "af229e5c-a70f-4354-bddc-4a2698802741"}}}], "length": {"value": 0.28336300000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "439d6b78-6099-4abb-8944-85f4bdab8a16", "name": "l(r:p1rdt6121-p1rdt8578)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "af229e5c-a70f-4354-bddc-4a2698802741"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2390c014-d418-4d63-8438-529a036487db"}}}], "length": {"value": 3.58548, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "1950c059-99fb-4401-9f5c-76a93b596633", "name": "l(r:p1rdt8578-p1rdt8583)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dbb79e10-21ba-4f04-b8a3-0cf711d26d40"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "975237e9-bd83-4a30-83ab-221eb7f85c65"}}}], "length": {"value": 0.101019, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "562e52da-0402-4236-9daa-19322b4c4c58", "name": "l(r:p1rdt8578-p1rdt8583)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "975237e9-bd83-4a30-83ab-221eb7f85c65"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb866499-9e9c-4394-bd76-d4320ba4934b"}}}], "length": {"value": 0.293916, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "2e7af12b-e8d8-4dd6-b6a9-cd3b777924ce", "name": "l(r:p1rdt8583-p1rhs7_1247)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec7726f8-0afb-4c35-8a1b-0691a8fb400d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dbb79e10-21ba-4f04-b8a3-0cf711d26d40"}}}], "length": {"value": 1.53928, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "7393d5be-c8ab-4241-b345-50487d39c030", "name": "fuse(r:p1rdt108-p1rdt93)p1r_16636", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "900d49ce-4834-4f99-8d74-a5e9d2f63ea0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4f100ee-0152-4e27-bf0e-2c7dea1537ad"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "3b608405-4c97-4531-bc3d-fd9d98d5eef0", "name": "fuse(r:p1rdt8190-p1rdt99)p1r_16637", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "092a9d51-a39c-4c05-905e-93fb1ae96ba2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b860d5c-43e4-429e-b945-378020e3f926"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "872c97b3-853e-44ec-9dc5-76b3b0c97047", "name": "fuse(r:p1rdt6121-p1rdt6123)p1r_17782", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2390c014-d418-4d63-8438-529a036487db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddf8f344-dcca-418d-850e-745f18d29660"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "eebb5679-e562-4c44-912d-f2a3cf81f9a7", "name": "fuse(r:p1rdt8583-p1rdt8584)p1r_18243", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dbb79e10-21ba-4f04-b8a3-0cf711d26d40"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0747505-3381-4df0-a86e-3859acac8496"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "96f5f10a-4b99-43c0-ace7-9392756edbb1", "name": "disswitch(r:p1rdt101-p1rdt8017)p1r_21072", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d8e5d83-cd9c-4527-9eef-6219c98dfe93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a09cdbca-4e7b-4d9a-b479-515074964171"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "PositiveDistance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}], "time_series": {"directory": "p1rhs7_1247_time_series"}} \ No newline at end of file +{"name": null, "description": null, "uuid": "46939f3b-e363-402b-96d5-075fea00bb3c", "data_format_version": "1.4.0", "components": [{"uuid": "b3ec0470-4645-4817-8d9e-36a62dd25e7b", "name": "", "limit_type": "min", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "base"}}, "value": {"value": 37.84531014537997, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}}, {"uuid": "6f2e6cad-94d8-43ba-82be-43800c8ff5c3", "name": "", "limit_type": "max", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "base"}}, "value": {"value": 41.82902700278839, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}}, {"uuid": "198717db-85ba-42fb-bb64-8404694680f4", "name": "", "x": 38.64060097099336, "y": -122.50688851789585, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "574ab810-c1b0-4662-8c4d-f32ab6893a36", "name": "p1rhs7_69", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "b3ec0470-4645-4817-8d9e-36a62dd25e7b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "6f2e6cad-94d8-43ba-82be-43800c8ff5c3"}}}], "nominal_voltage": {"value": 39.83716857408418, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "198717db-85ba-42fb-bb64-8404694680f4"}}}}, {"uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e", "name": "", "limit_type": "min", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "base"}}, "value": {"value": 6.839579963954902, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}}, {"uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4", "name": "", "limit_type": "max", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "base"}}, "value": {"value": 7.559535749634366, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}}, {"uuid": "43cd04c2-460c-452d-86bf-a5589f142291", "name": "", "x": 38.64000605387684, "y": -122.50715315149552, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "30052484-94f2-43a3-abb7-9314d4593c20", "name": "sb10_p1rhs7_1247_bus_10_6", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "43cd04c2-460c-452d-86bf-a5589f142291"}}}}, {"uuid": "03718c17-c4ff-4e1c-8455-8fcf4a4af180", "name": "", "x": 38.63991059999376, "y": -122.50713209215856, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ed5e3889-e8c8-4215-adb8-9880f8937da5", "name": "p1rdt6488-p1rhs7_1247x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "03718c17-c4ff-4e1c-8455-8fcf4a4af180"}}}}, {"uuid": "0488d677-5c3a-4447-9757-a609b80ee957", "name": "", "x": 38.64000458987126, "y": -122.50680575213045, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "23779a0d-9859-4591-b4ce-7ec704401d42", "name": "sb10_p1rhs7_1247_bus_10_7", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0488d677-5c3a-4447-9757-a609b80ee957"}}}}, {"uuid": "55ae0586-0c23-44a5-9795-611001c2b35b", "name": "", "x": 38.63990849507586, "y": -122.50663270624317, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1548dd91-bc3d-4a2c-903f-48e11159c558", "name": "p1rdt7711-p1rhs7_1247x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "55ae0586-0c23-44a5-9795-611001c2b35b"}}}}, {"uuid": "fef667d2-e160-4e42-93ec-3fe9b5fa8815", "name": "", "x": 38.64015019482659, "y": -122.50741272190496, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f4d9a6e8-eb1b-454c-ae94-2eb435218fb9", "name": "sb10_p1rhs7_1247_bus_10_4", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fef667d2-e160-4e42-93ec-3fe9b5fa8815"}}}}, {"uuid": "2b867617-7e8c-4db9-ade6-b774fb29b86d", "name": "", "x": 38.64000705978231, "y": -122.50739198857364, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "14208aa5-3197-4c90-adf9-3067dae9b5f9", "name": "p1rdt5342-p1rhs7_1247x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2b867617-7e8c-4db9-ade6-b774fb29b86d"}}}}, {"uuid": "d32bc420-6934-4d7e-91ab-1e3398b02d2c", "name": "", "x": 38.640146717948795, "y": -122.5065876467693, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2427b8de-af1a-44f8-9774-724e635057fb", "name": "sb10_p1rhs7_1247_bus_10_5", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d32bc420-6934-4d7e-91ab-1e3398b02d2c"}}}}, {"uuid": "e9c98454-f906-4403-becb-00deac9c5c8c", "name": "", "x": 38.64000266679855, "y": -122.50634979050211, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ec7726f8-0afb-4c35-8a1b-0691a8fb400d", "name": "p1rdt8583-p1rhs7_1247x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e9c98454-f906-4403-becb-00deac9c5c8c"}}}}, {"uuid": "08b140ca-c960-474e-ac23-6e6580d6298c", "name": "", "x": 38.640398325892065, "y": -122.5068899064944, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "001adbd4-6616-4dce-83d2-025e896ada51", "name": "sb10_p1rhs7_1247_node_10_7", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "08b140ca-c960-474e-ac23-6e6580d6298c"}}}}, {"uuid": "0783a135-88c7-4b30-86a9-f2f6557c594a", "name": "", "x": 38.64033927342312, "y": -122.50702059026854, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3856ea8d-83da-4d2e-8f66-fae6c69b5db1", "name": "sb10_p1rhs7_1247_bus_10_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0783a135-88c7-4b30-86a9-f2f6557c594a"}}}}, {"uuid": "07d60bfb-ce5e-4d51-9638-eb8860046b02", "name": "", "x": 38.64024290434973, "y": -122.50678240569646, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c975b603-30a6-4ed1-bbae-696d1c5b0a3d", "name": "sb10_p1rhs7_1247_bus_10_3", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "07d60bfb-ce5e-4d51-9638-eb8860046b02"}}}}, {"uuid": "7fd62588-3463-4a61-8c5d-1bb88b8c086a", "name": "", "x": 38.640245008643895, "y": -122.50728179394365, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6263cae0-e97a-4044-a130-e971a626d3c1", "name": "sb10_p1rhs7_1247_bus_10_2", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7fd62588-3463-4a61-8c5d-1bb88b8c086a"}}}}, {"uuid": "09d479e2-73cb-4c6e-9182-419e2c7d9217", "name": "", "x": 38.64044600709302, "y": -122.50688957976658, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16bb904e-b153-4b0a-97f5-53ad7c6606d8", "name": "sb10_p1rhs7_1247_node_10_6", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "b3ec0470-4645-4817-8d9e-36a62dd25e7b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "6f2e6cad-94d8-43ba-82be-43800c8ff5c3"}}}], "nominal_voltage": {"value": 39.83716857408418, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "09d479e2-73cb-4c6e-9182-419e2c7d9217"}}}}, {"uuid": "154210fc-9811-4963-880a-2605cc049534", "name": "", "x": 38.64052944919371, "y": -122.50688900799106, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ca7962b4-686c-4bee-af8d-f1851b835adb", "name": "sb10_p1rhs7_1247_node_10_5", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "b3ec0470-4645-4817-8d9e-36a62dd25e7b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "6f2e6cad-94d8-43ba-82be-43800c8ff5c3"}}}], "nominal_voltage": {"value": 39.83716857408418, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "154210fc-9811-4963-880a-2605cc049534"}}}}, {"uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc", "name": "", "limit_type": "min", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "base"}}, "value": {"value": 0.11408441319187004, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}}, {"uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5", "name": "", "limit_type": "max", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "base"}}, "value": {"value": 0.12609329879101427, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}}, {"uuid": "c9b5dc22-6b6c-4e4f-bb66-434e7a4937bf", "name": "", "x": 38.58930068802498, "y": -122.47407241728135, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3541a1a-9680-4baf-9b87-a1322cb1a16a", "name": "p1rdt4964lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c9b5dc22-6b6c-4e4f-bb66-434e7a4937bf"}}}}, {"uuid": "cececd48-9462-4a04-90f8-afe07e75e821", "name": "", "x": 38.58928688389361, "y": -122.47412342379597, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "02e86824-b793-4080-9401-c6995a365baf", "name": "p1rlv10170", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cececd48-9462-4a04-90f8-afe07e75e821"}}}}, {"uuid": "b99a2ad7-5611-486b-890e-ec585d6cdc15", "name": "", "x": 38.58730261534203, "y": -122.47493972983303, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ab731358-e17f-4c48-b6f8-c7bb4c7701de", "name": "p1rdt4980lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b99a2ad7-5611-486b-890e-ec585d6cdc15"}}}}, {"uuid": "88aed81c-9aee-49c7-b399-6d35c3018dbd", "name": "", "x": 38.586999682758396, "y": -122.47455116112062, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "58f2b2c3-4f6f-4fd2-abb9-42ff665692bd", "name": "p1rlv10189", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "88aed81c-9aee-49c7-b399-6d35c3018dbd"}}}}, {"uuid": "d25f087f-69b4-4209-ac90-8818cc55484e", "name": "", "x": 38.5874921997227, "y": -122.47522897778698, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6b4caeee-6304-4a25-a7d8-44c6014b5e37", "name": "p1rlv10574", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d25f087f-69b4-4209-ac90-8818cc55484e"}}}}, {"uuid": "d4aaf336-5d7e-46b9-9bb6-f7d1ed0c4e09", "name": "", "x": 38.587371992400946, "y": -122.47517995477224, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aad9ea92-9403-4ac0-9aaf-7e845b8c7bb5", "name": "p1rlv10596", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d4aaf336-5d7e-46b9-9bb6-f7d1ed0c4e09"}}}}, {"uuid": "5b862a31-20f0-4f36-926e-88ecbddd6658", "name": "", "x": 38.58881837779083, "y": -122.47343065419352, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0375d197-ccd2-4ed8-9439-857b700cefb8", "name": "p1rdt5017lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5b862a31-20f0-4f36-926e-88ecbddd6658"}}}}, {"uuid": "609e696a-a153-4e81-a0de-294f1949fda2", "name": "", "x": 38.58885966670059, "y": -122.47344264204159, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3317d7c2-2588-426d-91fc-3d765b932da6", "name": "p1rlv10262", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "609e696a-a153-4e81-a0de-294f1949fda2"}}}}, {"uuid": "8925aa98-b97a-4609-928a-4c2fb1511718", "name": "", "x": 38.62911239194669, "y": -122.48794713837246, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7e33e473-8d5b-4704-bdab-56032991f94e", "name": "p1rdt5126lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8925aa98-b97a-4609-928a-4c2fb1511718"}}}}, {"uuid": "83e7ddaa-1339-44f6-924d-5a5f6a3cf8cf", "name": "", "x": 38.6290864193847, "y": -122.48790451626458, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8f7116b9-96c1-42c8-850f-7787f5fd0f96", "name": "p1rlv10491", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "83e7ddaa-1339-44f6-924d-5a5f6a3cf8cf"}}}}, {"uuid": "84da10da-2cca-45f7-9864-c2b1098caa40", "name": "", "x": 38.625434851806375, "y": -122.44516017839125, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dd4b469b-001b-4914-8e51-e98fe3f6babb", "name": "p1rdm10619", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "84da10da-2cca-45f7-9864-c2b1098caa40"}}}}, {"uuid": "791f4ebc-b1a0-4617-b265-6f27b679cd92", "name": "", "x": 38.625158815750815, "y": -122.44586307086524, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "31f26b28-fc9d-4b3d-b204-cf40f3478c44", "name": "p1rlv10521", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "791f4ebc-b1a0-4617-b265-6f27b679cd92"}}}}, {"uuid": "905821af-0745-45f1-9947-ecdae59a1230", "name": "", "x": 38.625299188790116, "y": -122.44505783200565, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e28a5f3a-4447-469a-85dd-e232d8c6d728", "name": "p1rdm10620", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "905821af-0745-45f1-9947-ecdae59a1230"}}}}, {"uuid": "fc3d809d-3c65-4bcc-8227-0daa8d5f70f7", "name": "", "x": 38.62519279357018, "y": -122.44542626681253, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "73ada6ad-ace7-46c1-80f7-2cb33cf4cdb3", "name": "p1rlv10641", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fc3d809d-3c65-4bcc-8227-0daa8d5f70f7"}}}}, {"uuid": "fe8f593f-9830-4c8d-8ac2-c631589cabcb", "name": "", "x": 38.625591389135096, "y": -122.44526633659068, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5f114a56-98d7-4fe8-b0b1-b8c4bc791cf9", "name": "p1rdt5140lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fe8f593f-9830-4c8d-8ac2-c631589cabcb"}}}}, {"uuid": "c0c3cf78-7bf0-4327-987d-79699acfeb78", "name": "", "x": 38.62571524353723, "y": -122.44537629052095, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e09d217e-44a5-4013-8d48-8546d6bb1dc3", "name": "p1rdm10621", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c0c3cf78-7bf0-4327-987d-79699acfeb78"}}}}, {"uuid": "b087818c-f0c4-44e8-86b3-a358f5f73403", "name": "", "x": 38.62565276187416, "y": -122.44550314021144, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "07f95ba5-92dd-465f-a38d-8e878243262b", "name": "p1rlv20071", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b087818c-f0c4-44e8-86b3-a358f5f73403"}}}}, {"uuid": "8efabcfe-13b9-41a1-adeb-db0ab55a0905", "name": "", "x": 38.622332296573816, "y": -122.44976008456518, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e071635-4071-470d-be09-4484cb90441a", "name": "p1rdt5142lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8efabcfe-13b9-41a1-adeb-db0ab55a0905"}}}}, {"uuid": "fe5c7977-cf01-48d0-8145-1e49d6d26df0", "name": "", "x": 38.62217684357621, "y": -122.44988366265912, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35d47036-a044-4c67-b5b5-0006e2a3b68e", "name": "p1rlv10523", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fe5c7977-cf01-48d0-8145-1e49d6d26df0"}}}}, {"uuid": "919ab874-ec10-4b43-841d-de5560c6f8ce", "name": "", "x": 38.62245506643117, "y": -122.44964029908394, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a5717e0-080e-46ae-918a-64fe4fcba5d7", "name": "p1rlv10616", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "919ab874-ec10-4b43-841d-de5560c6f8ce"}}}}, {"uuid": "2108dc95-1071-454c-a014-d592b62560ac", "name": "", "x": 38.58825755415666, "y": -122.46710557327793, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ec20ad2-b04f-43fc-ad8d-d41746549a57", "name": "p1rdt5153lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2108dc95-1071-454c-a014-d592b62560ac"}}}}, {"uuid": "8ae7ce00-9a27-47f2-9b8b-068f0cd24e76", "name": "", "x": 38.58776776322457, "y": -122.46703633124763, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a302271d-4cf3-45ff-9308-b9cf31fbefa3", "name": "p1rlv10538", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8ae7ce00-9a27-47f2-9b8b-068f0cd24e76"}}}}, {"uuid": "cae2d3e5-816f-4b6b-958a-6c6d061dfe81", "name": "", "x": 38.58793840849323, "y": -122.4669087674479, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cfbe5665-c020-455a-addc-d3f9514735ed", "name": "p1rlv10586", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cae2d3e5-816f-4b6b-958a-6c6d061dfe81"}}}}, {"uuid": "b2f0ad91-48b4-488d-b58e-a9a570478b91", "name": "", "x": 38.58801998355576, "y": -122.46701150268488, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b91354e-ce50-44d0-a959-fa451bb9cf20", "name": "p1rlv10610", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b2f0ad91-48b4-488d-b58e-a9a570478b91"}}}}, {"uuid": "daf9b693-80a3-42ee-8706-c161353b3bee", "name": "", "x": 38.62299459252021, "y": -122.44285578875113, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "85351f49-cb19-4f71-a6ae-a21f5a48af6f", "name": "p1rdt5155lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "daf9b693-80a3-42ee-8706-c161353b3bee"}}}}, {"uuid": "7717760f-23fb-40cd-a9b0-f0188f35b9f2", "name": "", "x": 38.62296860365152, "y": -122.44281318670158, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4829cd2f-7e61-4386-89ce-89d77d5ef5cf", "name": "p1rlv10540", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7717760f-23fb-40cd-a9b0-f0188f35b9f2"}}}}, {"uuid": "9413b231-e7d1-4a46-adac-dcb6f32db7d4", "name": "", "x": 38.623416278049106, "y": -122.44435741173649, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ba7e3a6b-f62f-432f-afe7-2ebbfc9abd59", "name": "p1rdt5159lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9413b231-e7d1-4a46-adac-dcb6f32db7d4"}}}}, {"uuid": "1c49be6d-fc4c-418f-9b44-644a6e2a42e2", "name": "", "x": 38.62339028972311, "y": -122.44431480889065, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6c722b89-fdaf-416f-863e-02b443375ba1", "name": "p1rlv10544", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1c49be6d-fc4c-418f-9b44-644a6e2a42e2"}}}}, {"uuid": "57af24fc-2f2e-4145-b371-ee77999bac6c", "name": "", "x": 38.62398776024399, "y": -122.44276641347568, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48efdcb9-083c-4e17-a1d2-acb1388f085e", "name": "p1rdt5172lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "57af24fc-2f2e-4145-b371-ee77999bac6c"}}}}, {"uuid": "1d70710d-9a07-4242-a38f-5d47bc190b51", "name": "", "x": 38.62338766087452, "y": -122.44294734474045, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c8a10822-398f-441e-a5ca-73303d832183", "name": "p1rlv10563", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d70710d-9a07-4242-a38f-5d47bc190b51"}}}}, {"uuid": "eb9ecf04-f209-4a45-9ca6-f9115d073e72", "name": "", "x": 38.618803618131444, "y": -122.45181229136102, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dd4155b2-ca55-41d7-bd35-98a5eec8c39a", "name": "p1rdt5179lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eb9ecf04-f209-4a45-9ca6-f9115d073e72"}}}}, {"uuid": "ef045117-9d8f-4b4a-a616-40bcd5391aa5", "name": "", "x": 38.61925559252727, "y": -122.4515026734116, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "94677ede-fd5c-4fbb-bfcd-98cf67b56913", "name": "p1rlv10573", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef045117-9d8f-4b4a-a616-40bcd5391aa5"}}}}, {"uuid": "fd077f51-6fff-413f-bf0e-4488154496fc", "name": "", "x": 38.61839344506758, "y": -122.45214101800151, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a0431d17-75da-48c1-965c-875f61b0e9bf", "name": "p1rlv10583", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fd077f51-6fff-413f-bf0e-4488154496fc"}}}}, {"uuid": "be95eaa2-f600-4067-97f2-e6070d375414", "name": "", "x": 38.62221649276758, "y": -122.44627684656544, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ae26acb3-c2c9-479c-9d19-c30bf00aa8c5", "name": "p1rdt5180lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be95eaa2-f600-4067-97f2-e6070d375414"}}}}, {"uuid": "be1285dd-72ff-4444-817f-574f0346a2c9", "name": "", "x": 38.622228136819786, "y": -122.44632961498499, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25141e20-0a65-4905-b37f-954ed1a8751c", "name": "p1rlv10576", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be1285dd-72ff-4444-817f-574f0346a2c9"}}}}, {"uuid": "10c2c882-6746-444f-b809-677b728156cf", "name": "", "x": 38.58486127149263, "y": -122.47507613100927, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3bbde2e8-42c0-486b-9759-78898d177f93", "name": "p1rdt5183lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10c2c882-6746-444f-b809-677b728156cf"}}}}, {"uuid": "560205af-2471-40f9-8e3e-65f51ade10de", "name": "", "x": 38.584860090382186, "y": -122.47502224179047, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cdfa726f-5606-4ae2-b358-ad664dd7b0e3", "name": "p1rlv10582", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "560205af-2471-40f9-8e3e-65f51ade10de"}}}}, {"uuid": "3337f64c-470e-47ce-a97e-4d4570af0515", "name": "", "x": 38.6246895952918, "y": -122.44633371298471, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1656cc28-8a5b-40da-887f-25605dd336aa", "name": "p1rdt5184lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3337f64c-470e-47ce-a97e-4d4570af0515"}}}}, {"uuid": "6bd43a1d-48a8-4497-b3e4-8d0ec3aab2bc", "name": "", "x": 38.624682565233414, "y": -122.4461539331612, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "53019a8a-b453-4add-9d2d-e4ab380fce67", "name": "p1rlv10589", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6bd43a1d-48a8-4497-b3e4-8d0ec3aab2bc"}}}}, {"uuid": "ddc1bf24-6112-491d-b9b2-c3ffeaac64de", "name": "", "x": 38.624602168391775, "y": -122.44630389385829, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "feb19590-c5f4-4982-9e99-20599f08cfe7", "name": "p1rlv10600", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ddc1bf24-6112-491d-b9b2-c3ffeaac64de"}}}}, {"uuid": "41225cc6-cdcb-463a-a44f-1fbec5c8f0f3", "name": "", "x": 38.62484662068028, "y": -122.44654326007226, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "374d5417-b2c4-4d16-9b91-d2f519921fd8", "name": "p1rlv10621", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "41225cc6-cdcb-463a-a44f-1fbec5c8f0f3"}}}}, {"uuid": "463f4f85-69a4-45bc-87ec-d0f8a40b0c82", "name": "", "x": 38.649308955445846, "y": -122.40285111885804, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf05c1bb-39cc-48b3-a576-18913e0cff13", "name": "p1rdt5195lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "463f4f85-69a4-45bc-87ec-d0f8a40b0c82"}}}}, {"uuid": "4935e47a-85c4-40c5-83a4-8c706d58814d", "name": "", "x": 38.649342089627496, "y": -122.40283537845332, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1b175fcb-d1ee-44eb-8f89-826e40c5db1d", "name": "p1rlv10615", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4935e47a-85c4-40c5-83a4-8c706d58814d"}}}}, {"uuid": "4d8947e5-f3a0-43f2-bb3c-c156b337ea40", "name": "", "x": 38.64914651543566, "y": -122.40280650016945, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3184f056-3b5f-403d-86a0-f9b28d6bb3e3", "name": "p1rlv10634", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d8947e5-f3a0-43f2-bb3c-c156b337ea40"}}}}, {"uuid": "26aa33e2-1edf-424f-b548-410cbaee9b20", "name": "", "x": 38.58803256102546, "y": -122.4709126113251, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "03e7bfdb-ff8b-4142-95ef-8d848ff5d2db", "name": "p1rdt5200lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "26aa33e2-1edf-424f-b548-410cbaee9b20"}}}}, {"uuid": "eedd822e-ac93-4283-b769-4a115d88068e", "name": "", "x": 38.58800658229211, "y": -122.47087001955629, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32406d7d-51f9-4c16-900b-526985e5f62b", "name": "p1rlv10627", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eedd822e-ac93-4283-b769-4a115d88068e"}}}}, {"uuid": "5e69e0e7-a169-409b-aa08-29275566fae9", "name": "", "x": 38.62310262007371, "y": -122.44472743619623, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b8162a8c-5339-4f42-bd7a-b6dbc5ff463b", "name": "p1rdt5201lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5e69e0e7-a169-409b-aa08-29275566fae9"}}}}, {"uuid": "8a684d6a-e879-403d-b98a-145e2c82abb8", "name": "", "x": 38.623076631881446, "y": -122.44468483339944, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e183b3e8-d995-4f1e-baee-8d9d4add157e", "name": "p1rlv10629", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8a684d6a-e879-403d-b98a-145e2c82abb8"}}}}, {"uuid": "009b7291-1ad4-4e31-812f-20a22582b7f8", "name": "", "x": 38.647579222155, "y": -122.40883933742933, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "39eaedd7-75b6-449f-8ff6-6e31f6e74504", "name": "p1rdt5202lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "009b7291-1ad4-4e31-812f-20a22582b7f8"}}}}, {"uuid": "737a5433-f6cd-4820-bed5-b01766e07a38", "name": "", "x": 38.64738178775039, "y": -122.40899959560872, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8d60a935-dc9b-48ea-8ee7-9b682452035e", "name": "p1rlv10630", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "737a5433-f6cd-4820-bed5-b01766e07a38"}}}}, {"uuid": "a1331dcf-bb83-4354-a0d1-9adaf14bd4a2", "name": "", "x": 38.645656291690415, "y": -122.4075034535507, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "599a2995-33d5-4bcc-8cd3-585ea37577cd", "name": "p1rdt5206lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a1331dcf-bb83-4354-a0d1-9adaf14bd4a2"}}}}, {"uuid": "76105b9d-ef6e-4669-aa1a-d7354b4c1846", "name": "", "x": 38.64561400003638, "y": -122.40750498256921, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e9510bd0-2bba-4522-bfbe-20b94ea400b6", "name": "p1rlv10637", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "76105b9d-ef6e-4669-aa1a-d7354b4c1846"}}}}, {"uuid": "3b3ae9e8-ee45-4b39-a9d2-b653896ffc6e", "name": "", "x": 38.65641154150713, "y": -122.39587823120766, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c650eda9-132b-4419-a055-ad68037c7772", "name": "p1rdt5218lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3b3ae9e8-ee45-4b39-a9d2-b653896ffc6e"}}}}, {"uuid": "f8592191-94d2-423d-a9cc-66bf4448c219", "name": "", "x": 38.656425923289945, "y": -122.39592902455765, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8198c1c5-67e0-49b9-b11a-1f266f7f4bcb", "name": "p1rlv10663", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f8592191-94d2-423d-a9cc-66bf4448c219"}}}}, {"uuid": "cc50144a-f184-4913-a41b-8e0739907a56", "name": "", "x": 38.641472751242716, "y": -122.48093037801921, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5f252d81-66ee-40a6-bce7-2891e06b39e4", "name": "p1rdt5236lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc50144a-f184-4913-a41b-8e0739907a56"}}}}, {"uuid": "6a6587af-c013-4f7f-a20c-cca2a39b8c90", "name": "", "x": 38.64148709617754, "y": -122.48098117829157, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d3d48c0e-704d-4205-94a2-ee74be7ae350", "name": "p1rlv10720", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a6587af-c013-4f7f-a20c-cca2a39b8c90"}}}}, {"uuid": "69d6c981-12fa-4fb6-b646-c5cc5e4d9eaf", "name": "", "x": 38.641937121819915, "y": -122.50369495559332, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e01069aa-388b-4362-9d02-a164f173dc20", "name": "p1rdt5342lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "69d6c981-12fa-4fb6-b646-c5cc5e4d9eaf"}}}}, {"uuid": "dc80310e-0c48-4dc4-ba11-988bd5a787f0", "name": "", "x": 38.64182806242219, "y": -122.50347514079304, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75dbf8f0-4cb6-49b7-a2a5-f98e9ff4b8df", "name": "p1rlv10955", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dc80310e-0c48-4dc4-ba11-988bd5a787f0"}}}}, {"uuid": "f9149994-925b-428c-8a33-66b8460df8e8", "name": "", "x": 38.642018719214704, "y": -122.50380705470455, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0a8fc823-6fe8-4a3b-9437-68aa751f5e3b", "name": "p1rlv11048", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f9149994-925b-428c-8a33-66b8460df8e8"}}}}, {"uuid": "86ec09c9-13eb-44cd-a1b1-3711d57cfccb", "name": "", "x": 38.642205431006985, "y": -122.4576909223735, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "34a1276e-c702-4c69-b7b1-566d400da2de", "name": "p1rdt5472lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "86ec09c9-13eb-44cd-a1b1-3711d57cfccb"}}}}, {"uuid": "c8226150-c622-4980-9f33-95cb9cf66220", "name": "", "x": 38.64217944750302, "y": -122.4576483036143, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f949a06a-817e-4666-95bb-9536ce06a694", "name": "p1rlv11380", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c8226150-c622-4980-9f33-95cb9cf66220"}}}}, {"uuid": "d51b82c8-7885-4679-b8ed-12a631d090e7", "name": "", "x": 38.63960343978653, "y": -122.45649923239668, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5d181674-9355-488b-8a3f-5b7c844c35a5", "name": "p1rdt5475lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d51b82c8-7885-4679-b8ed-12a631d090e7"}}}}, {"uuid": "c119fba5-939c-479d-8bec-f034962dca28", "name": "", "x": 38.63981590397471, "y": -122.45628682931535, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e0c23aea-471f-4d10-9500-1bc14a67d7e7", "name": "p1rlv11384", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c119fba5-939c-479d-8bec-f034962dca28"}}}}, {"uuid": "f9b337b1-5557-4cd2-90b5-fe2127096eaf", "name": "", "x": 38.63963394395313, "y": -122.45652552675769, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7f512d86-c9d9-4f58-9d5a-418d0732dc94", "name": "p1rlv11386", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f9b337b1-5557-4cd2-90b5-fe2127096eaf"}}}}, {"uuid": "ee00163c-6526-4f99-80db-96be6a310440", "name": "", "x": 38.63927702838603, "y": -122.4566815679821, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9fd316b0-fd98-4193-9c1b-aaa7d92a4284", "name": "p1rlv11397", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ee00163c-6526-4f99-80db-96be6a310440"}}}}, {"uuid": "68f4463f-0f9f-4317-a2f9-fbe04b0afa9d", "name": "", "x": 38.639428183564455, "y": -122.46174457730311, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0888f4c5-e037-4891-99fb-fd43934ffae0", "name": "p1rdt5476lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "68f4463f-0f9f-4317-a2f9-fbe04b0afa9d"}}}}, {"uuid": "49097a9b-5c02-4d19-9fce-192f24b100ec", "name": "", "x": 38.639434265073014, "y": -122.46179953026234, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2115e8bb-fe49-49ad-8687-68feca212557", "name": "p1rlv11385", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "49097a9b-5c02-4d19-9fce-192f24b100ec"}}}}, {"uuid": "9f133821-96eb-4579-aee6-925be1a09527", "name": "", "x": 38.642101120835456, "y": -122.45608173877747, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fafd64c3-efe5-4684-b06f-44e4c8555aa4", "name": "p1rdt5477lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9f133821-96eb-4579-aee6-925be1a09527"}}}}, {"uuid": "1cf42564-0cee-4e41-85fc-b6e4694082f9", "name": "", "x": 38.64166518451146, "y": -122.45668651807028, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cbca8c57-0da4-4368-9821-7a9ca4282173", "name": "p1rlv11387", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1cf42564-0cee-4e41-85fc-b6e4694082f9"}}}}, {"uuid": "c753ea66-6b44-4f63-9692-64bd0a9737e0", "name": "", "x": 38.63719096576592, "y": -122.45830192704182, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5107bc9c-f463-49f6-a92f-23c5730475e2", "name": "p1rdt5478lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c753ea66-6b44-4f63-9692-64bd0a9737e0"}}}}, {"uuid": "6e9acac3-2384-45c3-b797-5bcce4603394", "name": "", "x": 38.63771659092773, "y": -122.4583249236366, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "12377bf0-f258-4c29-ab26-e938c95ee25c", "name": "p1rlv11388", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6e9acac3-2384-45c3-b797-5bcce4603394"}}}}, {"uuid": "38e78d90-477b-4736-9dde-04ab72558727", "name": "", "x": 38.63670708849592, "y": -122.4582865622578, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "97aa01fe-2e60-4617-8c89-d36f425087fe", "name": "p1rlv11398", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "38e78d90-477b-4736-9dde-04ab72558727"}}}}, {"uuid": "4f990b5f-70ec-4d45-b79a-ee56910b1e0d", "name": "", "x": 38.64171847326658, "y": -122.45537480795159, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "004f56b2-ec94-4189-91b8-46b4af22faa6", "name": "p1rdm11569", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4f990b5f-70ec-4d45-b79a-ee56910b1e0d"}}}}, {"uuid": "b46ddb8c-258a-46e0-9cc5-ce3594b0f2a0", "name": "", "x": 38.64245774536079, "y": -122.45464667599991, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9b6420b1-3456-42fc-9266-c2b84e063cec", "name": "p1rlv11390", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b46ddb8c-258a-46e0-9cc5-ce3594b0f2a0"}}}}, {"uuid": "94a3ded1-2e9b-42c2-9115-27ab1198f1ad", "name": "", "x": 38.641798080115834, "y": -122.45558638857214, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "44ac9e38-8ae3-4102-822b-1c638a6c878a", "name": "p1rdt5480lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "94a3ded1-2e9b-42c2-9115-27ab1198f1ad"}}}}, {"uuid": "9c167415-a423-4f44-bf0d-2c02116b5458", "name": "", "x": 38.64189515756268, "y": -122.45575404043835, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8be902f6-4cca-4ce5-9f73-a1f96c65d8ef", "name": "p1rdm11570", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9c167415-a423-4f44-bf0d-2c02116b5458"}}}}, {"uuid": "b944b2db-b9e5-412c-9cf9-8b7a3f920690", "name": "", "x": 38.64223524158617, "y": -122.45524587802178, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a215d7dd-8081-4355-9c38-4fd3d2c859c7", "name": "p1rlv11401", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b944b2db-b9e5-412c-9cf9-8b7a3f920690"}}}}, {"uuid": "1b663de6-20e1-48d3-b3c9-6f141c4a5ca7", "name": "", "x": 38.64020129527885, "y": -122.45644080950349, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f213ee9e-6ae7-4e82-9f25-6fc456f45576", "name": "p1rdt5481lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1b663de6-20e1-48d3-b3c9-6f141c4a5ca7"}}}}, {"uuid": "eab215e8-2ae0-46fd-a218-fd08beaa74e3", "name": "", "x": 38.64014090557112, "y": -122.45641076765583, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e740a352-ac8f-4ae2-ace3-254fccd7f96f", "name": "p1rlv11392", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eab215e8-2ae0-46fd-a218-fd08beaa74e3"}}}}, {"uuid": "22a6c911-8788-4f98-b55b-a8a2368bf128", "name": "", "x": 38.640303433007105, "y": -122.45647848222762, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "996d3e44-142c-42fa-bf4f-2bd1777122dd", "name": "p1rlv11394", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "22a6c911-8788-4f98-b55b-a8a2368bf128"}}}}, {"uuid": "7db0ae48-3ebd-433d-9568-05f0c398309d", "name": "", "x": 38.64168447824798, "y": -122.45542011758508, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8a73d544-9f33-49d9-b648-c806addf3c06", "name": "p1rdt5483lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7db0ae48-3ebd-433d-9568-05f0c398309d"}}}}, {"uuid": "81ff1e3e-2885-4592-9965-5945d231f979", "name": "", "x": 38.64195529639681, "y": -122.45512160027936, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "29922f55-f36a-4b9e-8836-5f9dadd641b7", "name": "p1rlv11395", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "81ff1e3e-2885-4592-9965-5945d231f979"}}}}, {"uuid": "288eb15e-e98b-4fdb-824b-6b63988c8235", "name": "", "x": 38.6393583769313, "y": -122.45589692178642, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "40eaefce-482f-4a89-bec1-2c11bac2bfb7", "name": "p1rdt5485lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "288eb15e-e98b-4fdb-824b-6b63988c8235"}}}}, {"uuid": "9a233f64-0a3f-4005-ac29-8df3dc67c147", "name": "", "x": 38.63937273269481, "y": -122.45594771545282, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "68a9eead-8197-4e82-a444-2a4544ec9ddb", "name": "p1rlv11399", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9a233f64-0a3f-4005-ac29-8df3dc67c147"}}}}, {"uuid": "67bfd210-882e-4eb2-b12d-7335778f6e07", "name": "", "x": 38.57143813832739, "y": -122.49015904841082, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "28a6e44b-c6c7-4556-b4d8-d55359391c66", "name": "p1rdt5650lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "67bfd210-882e-4eb2-b12d-7335778f6e07"}}}}, {"uuid": "e6ad383e-e706-44b6-8583-c21c9e8f308d", "name": "", "x": 38.57142432703484, "y": -122.49021003925405, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "834a5733-5264-4adf-861a-25e494df3e37", "name": "p1rlv11671", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e6ad383e-e706-44b6-8583-c21c9e8f308d"}}}}, {"uuid": "3aaeb5f6-c3be-4c8d-ac2c-284fc845d759", "name": "", "x": 38.65464557723489, "y": -122.39724791960451, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "38d1de19-1f51-4875-acc2-a75e3d1a290e", "name": "p1rdt5653lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3aaeb5f6-c3be-4c8d-ac2c-284fc845d759"}}}}, {"uuid": "196dcfb1-cbe1-481a-b575-c37dc4ed0da8", "name": "", "x": 38.65508992916787, "y": -122.39723667691878, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "45f2a901-e4f7-4055-a3e2-b60c61d5033e", "name": "p1rlv11674", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "196dcfb1-cbe1-481a-b575-c37dc4ed0da8"}}}}, {"uuid": "63fded38-9e61-45e7-8ae6-58ed56c3a1c9", "name": "", "x": 38.57263362388283, "y": -122.495683769354, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "87e8c57e-67ff-439c-b28b-0fbdbfd62ea6", "name": "p1rdt5656lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "63fded38-9e61-45e7-8ae6-58ed56c3a1c9"}}}}, {"uuid": "59d4774b-339b-4dc2-9d3d-807731c082ae", "name": "", "x": 38.5726198101849, "y": -122.49573476001369, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8b2f121a-2202-43c0-8684-81913a5d6ea9", "name": "p1rlv11677", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59d4774b-339b-4dc2-9d3d-807731c082ae"}}}}, {"uuid": "c8f6dffd-c572-4d99-b2a4-19421d74334c", "name": "", "x": 38.57280585377797, "y": -122.4929323788313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ea73a91a-b052-486e-810b-1a5ad281e07b", "name": "p1rdt5662lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c8f6dffd-c572-4d99-b2a4-19421d74334c"}}}}, {"uuid": "d4bd3e1e-9577-4201-9f8e-450e5cb4257e", "name": "", "x": 38.57242796617633, "y": -122.49307054728973, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "02aef971-5f4a-4ca8-aa33-cce34517bd44", "name": "p1rlv11684", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d4bd3e1e-9577-4201-9f8e-450e5cb4257e"}}}}, {"uuid": "1c8ccecf-94f0-4086-9894-43ca68c27898", "name": "", "x": 38.56680617078412, "y": -122.49719640898832, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16a67a88-5d11-4eca-85fe-38c948ad362c", "name": "p1rdt5663lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1c8ccecf-94f0-4086-9894-43ca68c27898"}}}}, {"uuid": "da50b7f4-c1bf-47df-ab82-73a5722737b9", "name": "", "x": 38.5668199513191, "y": -122.49730717896358, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cda8e361-98b6-49bd-a3ff-30a036a3dc6f", "name": "p1rlv11686", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "da50b7f4-c1bf-47df-ab82-73a5722737b9"}}}}, {"uuid": "b4ec8b1c-107b-490d-9bb4-eb8aa4f0a2a2", "name": "", "x": 38.56665994983674, "y": -122.49716304017915, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e5b71ca5-a7ab-42f7-824a-bc43fc1708cc", "name": "p1rdm11909", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b4ec8b1c-107b-490d-9bb4-eb8aa4f0a2a2"}}}}, {"uuid": "23b77dd8-f10c-4624-953a-3e440aa570f4", "name": "", "x": 38.566580963860986, "y": -122.49765717235252, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "449098c3-4f65-4350-863f-4b7bc1f14493", "name": "p1rlv15645", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "23b77dd8-f10c-4624-953a-3e440aa570f4"}}}}, {"uuid": "1ba63c10-373f-4350-b961-c90fd652abb4", "name": "", "x": 38.5707010215685, "y": -122.51444963387745, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6d456893-4d89-455a-b1a5-4863aad6293a", "name": "p1rdt5728lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1ba63c10-373f-4350-b961-c90fd652abb4"}}}}, {"uuid": "1f21215a-9d08-4812-8efd-536b0eded845", "name": "", "x": 38.57009391258443, "y": -122.51433495859402, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f0ba1408-17da-4678-8b04-90c616c3fb48", "name": "p1rlv11779", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1f21215a-9d08-4812-8efd-536b0eded845"}}}}, {"uuid": "d07cefa0-6a4a-4ea1-833c-1f8c7239b2ec", "name": "", "x": 38.57127534957151, "y": -122.51454511366566, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3890375-c01d-44d2-93f9-8d9d60da8852", "name": "p1rlv11783", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d07cefa0-6a4a-4ea1-833c-1f8c7239b2ec"}}}}, {"uuid": "65b9e11a-d035-49fe-9c2f-a18adc520bfa", "name": "", "x": 38.56955818331602, "y": -122.51459989092113, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "95f81d7a-a6af-4843-bfa1-002abc7ff870", "name": "p1rdt5729lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65b9e11a-d035-49fe-9c2f-a18adc520bfa"}}}}, {"uuid": "03cf9cc3-74d3-41be-ac9e-4c958be1448f", "name": "", "x": 38.56953222036641, "y": -122.51455729408103, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6e9a574d-9537-417a-a811-e22d84b8ea53", "name": "p1rlv11780", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "03cf9cc3-74d3-41be-ac9e-4c958be1448f"}}}}, {"uuid": "0a193e3d-f76a-4d4c-a33b-8d6eb8250e44", "name": "", "x": 38.57213402094206, "y": -122.51802514483155, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2dd206bc-965d-46c9-8fdb-8c158c7bba05", "name": "p1rdt5730lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a193e3d-f76a-4d4c-a33b-8d6eb8250e44"}}}}, {"uuid": "0198df5e-1335-4d36-b7fa-ea83c51eda03", "name": "", "x": 38.57199490295793, "y": -122.51856958078595, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b66df0bc-6159-42fa-bf49-b8ad17d0e6aa", "name": "p1rlv11784", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0198df5e-1335-4d36-b7fa-ea83c51eda03"}}}}, {"uuid": "1dd4f217-6d64-4bf3-be52-b765773001a9", "name": "", "x": 38.572056756934636, "y": -122.51827070037027, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b15fc66-89d9-483b-9c9f-9b0f39a63b29", "name": "p1rlv11786", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1dd4f217-6d64-4bf3-be52-b765773001a9"}}}}, {"uuid": "3142c953-b8bb-4934-aa7e-9394d697aafe", "name": "", "x": 38.572019292356316, "y": -122.51792656501027, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "64ee7f4c-b91a-4a25-b85d-a91b83777c1f", "name": "p1rdm12071", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3142c953-b8bb-4934-aa7e-9394d697aafe"}}}}, {"uuid": "ea02cc30-f701-4e2e-af04-30113338ce57", "name": "", "x": 38.571920919935685, "y": -122.51811089442202, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "28fd9f7c-0195-4529-a972-aa60eced47d2", "name": "p1rlv11781", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea02cc30-f701-4e2e-af04-30113338ce57"}}}}, {"uuid": "bb99e5fd-69c7-462b-8027-3c89a73aaa07", "name": "", "x": 38.56688129837257, "y": -122.51477378591451, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6e414162-eda7-4cf2-9116-fc24af9461bf", "name": "p1rdt5731lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bb99e5fd-69c7-462b-8027-3c89a73aaa07"}}}}, {"uuid": "a7bd841c-64ad-46a9-9b40-c7c407b24606", "name": "", "x": 38.5669221751359, "y": -122.51444813822336, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "496fc854-bbf8-463b-b16c-12dd1b444cc6", "name": "p1rlv11782", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a7bd841c-64ad-46a9-9b40-c7c407b24606"}}}}, {"uuid": "9b3e1b1d-5f5a-4ed6-bba2-f666acf4a2f6", "name": "", "x": 38.56702296960097, "y": -122.51484921518147, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7103c2f0-8160-434f-b4b3-edfbd7e97464", "name": "p1rdm12075", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9b3e1b1d-5f5a-4ed6-bba2-f666acf4a2f6"}}}}, {"uuid": "72915b72-842d-4d23-8777-a66df68ae209", "name": "", "x": 38.5670581599183, "y": -122.51464236147093, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ed0eb774-fcc3-417f-a8a4-fbdb825cc106", "name": "p1rlv11785", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "72915b72-842d-4d23-8777-a66df68ae209"}}}}, {"uuid": "ac2ebf07-87cc-46ac-affc-3aad7a0927ef", "name": "", "x": 38.57345429314894, "y": -122.51994138004522, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9974869d-7d87-4a27-9606-076cd7799953", "name": "p1rdt5840lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ac2ebf07-87cc-46ac-affc-3aad7a0927ef"}}}}, {"uuid": "dc36d120-77b5-4b62-95f8-a90964499200", "name": "", "x": 38.57328942198139, "y": -122.51998442674298, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1dfd848-b639-41b5-ad95-2c03a51bd36b", "name": "p1rlv12028", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dc36d120-77b5-4b62-95f8-a90964499200"}}}}, {"uuid": "0c5bf3c3-b2bf-4b42-95ef-eb2a0f8846dd", "name": "", "x": 38.573586478514756, "y": -122.51990209164686, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fc4d79bb-8ba3-4146-9d50-16db48ffec22", "name": "p1rlv12157", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0c5bf3c3-b2bf-4b42-95ef-eb2a0f8846dd"}}}}, {"uuid": "b2724222-42d6-4b39-9bdc-a131b20c18d3", "name": "", "x": 38.61540289404265, "y": -122.4340916885271, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "751d2f2e-bb6f-4ca6-9e86-0e2b5ff3f92a", "name": "p1rdt5923lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b2724222-42d6-4b39-9bdc-a131b20c18d3"}}}}, {"uuid": "f3ca5954-1325-4b71-ab86-ab13dee31042", "name": "", "x": 38.615385277507826, "y": -122.43359039737986, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "df9d9de2-6929-48a4-a390-c0e2f129b374", "name": "p1rlv12214", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f3ca5954-1325-4b71-ab86-ab13dee31042"}}}}, {"uuid": "00db6112-34c3-46a6-abeb-4f179fbbd1a9", "name": "", "x": 38.615361354746774, "y": -122.43423382325552, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c4d26673-c304-41de-8b5b-149552601ba4", "name": "p1rlv12217", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "00db6112-34c3-46a6-abeb-4f179fbbd1a9"}}}}, {"uuid": "63fba15d-7056-4866-a483-76cfd4b7b3d1", "name": "", "x": 38.61582271842178, "y": -122.43459776600604, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cee79fe8-f140-4be9-aa6b-d56e37fb6857", "name": "p1rlv12222", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "63fba15d-7056-4866-a483-76cfd4b7b3d1"}}}}, {"uuid": "ef651d7a-fc6b-426f-b064-fc2e60a74988", "name": "", "x": 38.61514654148174, "y": -122.43395232342587, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e8e1f797-9417-447c-8a08-cf00a462ef14", "name": "p1rlv12225", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef651d7a-fc6b-426f-b064-fc2e60a74988"}}}}, {"uuid": "7c88c271-f3f6-45d4-9919-0e24699d4215", "name": "", "x": 38.586418831345604, "y": -122.50394128809963, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d654945d-b71d-4943-86a2-5830fca200c9", "name": "p1rdt6038lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7c88c271-f3f6-45d4-9919-0e24699d4215"}}}}, {"uuid": "ab853430-e034-4565-b98b-2589bd82df86", "name": "", "x": 38.58644635289331, "y": -122.50405591684549, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b42c2471-9114-4042-980e-dd226ad024a3", "name": "p1rlv12538", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ab853430-e034-4565-b98b-2589bd82df86"}}}}, {"uuid": "3d46fae0-0a33-4fd5-ac7e-6282cd5526e1", "name": "", "x": 38.583699762043224, "y": -122.50722384389097, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e5ae7bbf-f53e-4ae2-8145-bf56ce935094", "name": "p1rdt6043lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3d46fae0-0a33-4fd5-ac7e-6282cd5526e1"}}}}, {"uuid": "8037a8ee-3906-490a-9533-13016db8fd6c", "name": "", "x": 38.583590695705574, "y": -122.50712562826531, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4c42d772-e2a8-45d4-9cf2-2edd7a567b35", "name": "p1rlv12552", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8037a8ee-3906-490a-9533-13016db8fd6c"}}}}, {"uuid": "2aa9b7fa-506a-4f8c-8242-7ecbcfa25a2d", "name": "", "x": 38.58378667878022, "y": -122.50658466351123, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b3e53a11-6c13-4d27-89f2-2abbd28f69ac", "name": "p1rdm12875", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2aa9b7fa-506a-4f8c-8242-7ecbcfa25a2d"}}}}, {"uuid": "65da88d8-f338-4c87-9275-83b61c7bfc38", "name": "", "x": 38.58345266624825, "y": -122.50644917302039, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a29aec49-62a4-41ec-a67c-a84470a23f7b", "name": "p1rlv12553", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65da88d8-f338-4c87-9275-83b61c7bfc38"}}}}, {"uuid": "ea0e1728-da0c-415a-b2d8-63292335ef42", "name": "", "x": 38.58361036220623, "y": -122.50751586004849, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b748c697-b624-43f0-b375-5024d8cff92b", "name": "p1rdm12876", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea0e1728-da0c-415a-b2d8-63292335ef42"}}}}, {"uuid": "279d7791-7332-446f-84ff-965c7c9af534", "name": "", "x": 38.58369185365201, "y": -122.50760715446228, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75a47101-b6df-473e-9c7b-96e076c17931", "name": "p1rlv12559", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "279d7791-7332-446f-84ff-965c7c9af534"}}}}, {"uuid": "533b497d-f2b9-4c9a-b5d2-76e4e9c93a3c", "name": "", "x": 38.58357450876428, "y": -122.50756203032971, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3082eb6b-1a9f-4b6e-930e-f58173fe02ac", "name": "p1rdm12877", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "533b497d-f2b9-4c9a-b5d2-76e4e9c93a3c"}}}}, {"uuid": "efefb47a-9073-4b89-a2b8-7be8b197bb61", "name": "", "x": 38.58361995350426, "y": -122.5076535708703, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8b0417d3-820d-4daa-aec5-3dcf34e40e00", "name": "p1rlv12562", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "efefb47a-9073-4b89-a2b8-7be8b197bb61"}}}}, {"uuid": "6989f2f9-0ff1-40bd-a0b5-15527010b9ad", "name": "", "x": 38.583744918789954, "y": -122.50735404765867, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b2e2d1a7-039c-4b29-a061-b814ac675e3b", "name": "p1rdt6046lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6989f2f9-0ff1-40bd-a0b5-15527010b9ad"}}}}, {"uuid": "efcefbeb-719b-4ce3-b9ad-5d962103723a", "name": "", "x": 38.5839884657107, "y": -122.50742142633933, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4fe4d6ae-cca5-476c-981a-a1dcd27b1e84", "name": "p1rlv12557", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "efcefbeb-719b-4ce3-b9ad-5d962103723a"}}}}, {"uuid": "313e68dc-5043-4c00-aeb7-0a6788fddbe1", "name": "", "x": 38.5843554229652, "y": -122.50614844559887, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "21e75ccd-7e21-4f0d-890c-81aa6b33b109", "name": "p1rdt6047lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "313e68dc-5043-4c00-aeb7-0a6788fddbe1"}}}}, {"uuid": "a3824258-2643-48e3-8a13-8ebabaac90ac", "name": "", "x": 38.584325151037234, "y": -122.50605283115296, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0a427f20-861a-4616-9443-265beaeccca3", "name": "p1rlv12558", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a3824258-2643-48e3-8a13-8ebabaac90ac"}}}}, {"uuid": "1b8d5c33-b1ec-42d0-a6da-c5736badbefd", "name": "", "x": 38.605026243337974, "y": -122.47603639568145, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "01be483b-09f4-450e-a39d-78692c40ee8b", "name": "p1rdt6208lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1b8d5c33-b1ec-42d0-a6da-c5736badbefd"}}}}, {"uuid": "39d40bfc-7bc0-40d3-8121-d070af0c9f8b", "name": "", "x": 38.60501243846355, "y": -122.47608741299466, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "019e419c-9f88-455a-bf48-b89531ed9e51", "name": "p1rlv12936", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "39d40bfc-7bc0-40d3-8121-d070af0c9f8b"}}}}, {"uuid": "384d4ef5-af8c-43a0-a01a-b48e88a27593", "name": "", "x": 38.60004659977005, "y": -122.48124037604637, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "73f78740-2ec5-4ad8-b7fb-40f4a72b730e", "name": "p1rdt6221lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "384d4ef5-af8c-43a0-a01a-b48e88a27593"}}}}, {"uuid": "e8e66f12-8da3-41bd-b6fa-3dcac2ae471f", "name": "", "x": 38.60002062477275, "y": -122.48119777346218, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8418804f-aad5-49df-9916-f427da5089c1", "name": "p1rlv12959", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e8e66f12-8da3-41bd-b6fa-3dcac2ae471f"}}}}, {"uuid": "5aef84c3-b54b-424d-8ebe-45dc09d4dd79", "name": "", "x": 38.604436381862065, "y": -122.47563389239149, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3154eee7-a1ba-4b9d-9e91-bab55529d358", "name": "p1rdt6226lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5aef84c3-b54b-424d-8ebe-45dc09d4dd79"}}}}, {"uuid": "a4d56043-79b9-4411-b7b6-c7e551d90dfa", "name": "", "x": 38.604742034520584, "y": -122.47609857017211, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be845651-8e1c-4b6d-8633-fcbdfb1fd5d4", "name": "p1rlv12971", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a4d56043-79b9-4411-b7b6-c7e551d90dfa"}}}}, {"uuid": "2b9957d6-67cd-47ad-8f4b-d0ec588d795e", "name": "", "x": 38.60407996866283, "y": -122.47516164611108, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "646058a3-cda7-4723-bd0f-05d305fe7c11", "name": "p1rlv20185", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2b9957d6-67cd-47ad-8f4b-d0ec588d795e"}}}}, {"uuid": "459fe982-19fb-4fc7-937f-3429aa535d9f", "name": "", "x": 38.61627084774632, "y": -122.45497361088964, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "72ce0706-6b32-4b4b-9bf3-fd1f5a6af5ca", "name": "p1rdt6268lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "459fe982-19fb-4fc7-937f-3429aa535d9f"}}}}, {"uuid": "9667d696-5ea7-451e-9dd5-318e13202abf", "name": "", "x": 38.616595375163186, "y": -122.45499188425644, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3072c6c-3a40-4e49-bd00-febc8268b135", "name": "p1rlv13043", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9667d696-5ea7-451e-9dd5-318e13202abf"}}}}, {"uuid": "5b18d64b-c7b4-4e7f-b793-a467aa5f1eb0", "name": "", "x": 38.61557658935668, "y": -122.45489621541526, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4209bdad-276f-4e07-93e0-78b162ce95cf", "name": "p1rlv13047", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5b18d64b-c7b4-4e7f-b793-a467aa5f1eb0"}}}}, {"uuid": "f0178992-d931-4425-b1f8-6cf772629d45", "name": "", "x": 38.61659769116569, "y": -122.45488097254983, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "21c6ea4f-ec9d-424e-8743-7175408f9e2c", "name": "p1rlv13054", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f0178992-d931-4425-b1f8-6cf772629d45"}}}}, {"uuid": "cb47612f-823d-4fd9-b8da-f9f951b87220", "name": "", "x": 38.615484628332915, "y": -122.45948878298002, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "79c91fa8-15ad-4e8d-96bd-2cad395dd280", "name": "p1rdt6269lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb47612f-823d-4fd9-b8da-f9f951b87220"}}}}, {"uuid": "5f7b1184-1a50-4c3b-abc1-6f10d6b0e56b", "name": "", "x": 38.61545864547562, "y": -122.45944617926628, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fa31c772-8460-4624-a123-64b87ca8d332", "name": "p1rlv13044", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5f7b1184-1a50-4c3b-abc1-6f10d6b0e56b"}}}}, {"uuid": "e5f6f0cd-c468-47f3-8889-ba4631b16481", "name": "", "x": 38.61293890712679, "y": -122.45937135963467, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5adb2083-3d46-48a7-8996-37c0781b0215", "name": "p1rdt6270lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e5f6f0cd-c468-47f3-8889-ba4631b16481"}}}}, {"uuid": "d0437a27-08ad-41e0-a4a5-0be10eada9ba", "name": "", "x": 38.61312062731428, "y": -122.45970448051091, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6070414d-09e7-48a7-aec0-c105cc0f1a93", "name": "p1rlv13045", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d0437a27-08ad-41e0-a4a5-0be10eada9ba"}}}}, {"uuid": "a6648dc2-4180-476b-84b9-d71723671f17", "name": "", "x": 38.61305606107207, "y": -122.459383355912, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5edc15fb-49d5-4052-8fad-4979578f6ed1", "name": "p1rlv13046", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a6648dc2-4180-476b-84b9-d71723671f17"}}}}, {"uuid": "6e31ef12-0466-48cc-9ff0-19a2da1c50f8", "name": "", "x": 38.612568269488285, "y": -122.45913432583363, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "86d59550-d7c8-47e1-a6bc-14b2d50de58c", "name": "p1rlv13052", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6e31ef12-0466-48cc-9ff0-19a2da1c50f8"}}}}, {"uuid": "a27adeee-5e06-4c0b-935d-a908465d154f", "name": "", "x": 38.61201252826336, "y": -122.45742705644044, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1335e64c-9f37-4e73-a37f-8f76737cabff", "name": "p1rdt6271lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a27adeee-5e06-4c0b-935d-a908465d154f"}}}}, {"uuid": "e19ce3da-55ab-4c6b-ad4c-5f038c6b2ffb", "name": "", "x": 38.6124662872462, "y": -122.45657372759852, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "569078be-37c2-4c05-8455-91945eb7fdb9", "name": "p1rlv13048", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e19ce3da-55ab-4c6b-ad4c-5f038c6b2ffb"}}}}, {"uuid": "f6a8b3a9-1c2a-45e7-a53b-b1002f1822ad", "name": "", "x": 38.61056246852402, "y": -122.45546646876214, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "04422e0a-1952-422d-a201-5fafef1875db", "name": "p1rdt6272lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f6a8b3a9-1c2a-45e7-a53b-b1002f1822ad"}}}}, {"uuid": "d0a8d9b3-58c2-4f85-9b1b-a839988d3996", "name": "", "x": 38.61046043697304, "y": -122.45545178295872, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3ed85192-4c5a-4c15-ba21-1ba883b03ddd", "name": "p1rlv13049", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d0a8d9b3-58c2-4f85-9b1b-a839988d3996"}}}}, {"uuid": "170ec7fe-fcf7-4acf-b429-559cbeaf6976", "name": "", "x": 38.61065269092905, "y": -122.4554887580758, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e058437-0138-4305-a33e-d8fa61aed8cc", "name": "p1rlv13053", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "170ec7fe-fcf7-4acf-b429-559cbeaf6976"}}}}, {"uuid": "bc8f8b98-5280-45f9-8ac4-52ad1f005535", "name": "", "x": 38.61008611720184, "y": -122.45635048585197, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2b6739c0-1b15-42c1-9fdd-4d7f604a03ce", "name": "p1rdm13376", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bc8f8b98-5280-45f9-8ac4-52ad1f005535"}}}}, {"uuid": "68405c44-dbe2-4a6b-9268-accf72aead68", "name": "", "x": 38.61016439157834, "y": -122.45574115998643, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e9a855b0-538e-4fab-91f1-93b4ece09409", "name": "p1rlv13051", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "68405c44-dbe2-4a6b-9268-accf72aead68"}}}}, {"uuid": "e2efd60d-46ec-4832-9b23-6f31a690ecb5", "name": "", "x": 38.61026024108263, "y": -122.45636462882881, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b1db8c80-e791-4c31-a6f2-713aa665bf41", "name": "p1rdt6274lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e2efd60d-46ec-4832-9b23-6f31a690ecb5"}}}}, {"uuid": "cbd8342d-f215-4a5b-9bb6-d8f6f08670f7", "name": "", "x": 38.610392670089375, "y": -122.45638262926296, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e395985-4c66-49c9-9252-94d8078b8e8e", "name": "p1rdm13377", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cbd8342d-f215-4a5b-9bb6-d8f6f08670f7"}}}}, {"uuid": "4e8da740-8364-40d4-81e3-115c6cd3df80", "name": "", "x": 38.610432528075556, "y": -122.45587299013495, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16584dfd-537d-4b0d-a651-c73d0beabc6d", "name": "p1rlv13056", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4e8da740-8364-40d4-81e3-115c6cd3df80"}}}}, {"uuid": "fbf44c78-ce05-4b63-960e-76194f6ae49f", "name": "", "x": 38.610983387394924, "y": -122.45878265444647, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ba567584-fbee-44eb-b3f1-da24a0ce66a0", "name": "p1rdt6275lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fbf44c78-ce05-4b63-960e-76194f6ae49f"}}}}, {"uuid": "5111021a-6b72-40f1-b986-267d9c612a93", "name": "", "x": 38.61089111139205, "y": -122.45892869017909, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "387df3d3-5f03-47f4-8b16-bea8815e63d1", "name": "p1rlv13055", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5111021a-6b72-40f1-b986-267d9c612a93"}}}}, {"uuid": "b1bffdbe-f800-471c-a218-2352f3de7841", "name": "", "x": 38.611024903573316, "y": -122.45862905688004, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c83997dc-872f-494f-8c8a-7266c854fc48", "name": "p1rlv13058", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b1bffdbe-f800-471c-a218-2352f3de7841"}}}}, {"uuid": "8daf5a93-0aba-4efe-b6f8-87702fbd5e96", "name": "", "x": 38.61593370015664, "y": -122.45611332456588, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2f20ace2-5ec8-4451-b7e7-66f46c2c487b", "name": "p1rdt6276lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8daf5a93-0aba-4efe-b6f8-87702fbd5e96"}}}}, {"uuid": "cb93529c-6913-4fbe-a725-7e4dee686cdb", "name": "", "x": 38.616214343979955, "y": -122.45638463812467, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2c63d163-75bd-4d91-bcfa-229a2e331b1f", "name": "p1rlv13057", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb93529c-6913-4fbe-a725-7e4dee686cdb"}}}}, {"uuid": "ac857cdd-f51e-4fa1-9097-01222c65d188", "name": "", "x": 38.61560758048402, "y": -122.45574597720416, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8d2fa164-4c03-4bcd-a386-749ccd4e9001", "name": "p1rlv13062", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ac857cdd-f51e-4fa1-9097-01222c65d188"}}}}, {"uuid": "59b0c5c4-2dde-4be1-92d4-fc14c7f28bfc", "name": "", "x": 38.61608078908832, "y": -122.45806664881565, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e582b04d-a8d8-4ee9-8576-1e5941623c0b", "name": "p1rdt6277lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59b0c5c4-2dde-4be1-92d4-fc14c7f28bfc"}}}}, {"uuid": "ea6ecbce-6597-489c-806f-0b38415136ee", "name": "", "x": 38.616096280398985, "y": -122.45813147961287, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a1779b5b-1a6c-4511-9d4b-88026b430173", "name": "p1rlv13059", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea6ecbce-6597-489c-806f-0b38415136ee"}}}}, {"uuid": "b3dc1c19-d603-4d73-8550-c2b4745ed0ab", "name": "", "x": 38.616472312390336, "y": -122.45760251208678, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2b37eabc-787a-491f-bc4f-956f43a862ff", "name": "p1rdt6278lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b3dc1c19-d603-4d73-8550-c2b4745ed0ab"}}}}, {"uuid": "88ff6605-6274-48d5-a8df-b913f605e687", "name": "", "x": 38.61659895813833, "y": -122.45770269368248, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8767a040-da31-48d9-9473-0941856bcedc", "name": "p1rlv13060", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "88ff6605-6274-48d5-a8df-b913f605e687"}}}}, {"uuid": "d35605b8-f529-4dd5-ae8a-7cd432ad68bb", "name": "", "x": 38.635969271978226, "y": -122.41468609161443, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3a38eb6d-a625-42a1-95f6-bbf078d1447a", "name": "p1rdt6345lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d35605b8-f529-4dd5-ae8a-7cd432ad68bb"}}}}, {"uuid": "4016c322-b0a6-4180-bc76-3154deee1dad", "name": "", "x": 38.63598364556035, "y": -122.41473687445114, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c29c3206-b71d-41d1-8ad7-a693c8c25d4d", "name": "p1rlv13185", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4016c322-b0a6-4180-bc76-3154deee1dad"}}}}, {"uuid": "6cb57e62-5516-46bd-a1bd-16b0ff15d7fd", "name": "", "x": 38.638887372960305, "y": -122.42670366638174, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e40008af-ff50-42bd-8897-f663c27a436f", "name": "p1rdt6347lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6cb57e62-5516-46bd-a1bd-16b0ff15d7fd"}}}}, {"uuid": "e79a71dd-ab3c-4e4f-b0da-a0a3d2960fd9", "name": "", "x": 38.63887629434703, "y": -122.42675582564294, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ffbd17b6-b1a2-4e55-9052-67a84419bb9d", "name": "p1rlv13187", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e79a71dd-ab3c-4e4f-b0da-a0a3d2960fd9"}}}}, {"uuid": "effbfb8c-623e-49b9-a2a9-7c2b94ad9651", "name": "", "x": 38.63741237955581, "y": -122.41088141259655, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d84ac329-f314-41be-a2ee-89bc74789a18", "name": "p1rdt6348lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "effbfb8c-623e-49b9-a2a9-7c2b94ad9651"}}}}, {"uuid": "b0eb5a62-8284-4550-a2a3-f5fe56a755e1", "name": "", "x": 38.63776633109597, "y": -122.41081354844057, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "67ffcd9f-ba90-4da7-b3b6-46310e321590", "name": "p1rlv13188", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b0eb5a62-8284-4550-a2a3-f5fe56a755e1"}}}}, {"uuid": "05557a96-5314-4ed4-b7f0-eb914262c728", "name": "", "x": 38.63725354679822, "y": -122.41099009448936, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3f6d09e9-3592-4560-8626-0d7cb71ca56a", "name": "p1rlv13191", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "05557a96-5314-4ed4-b7f0-eb914262c728"}}}}, {"uuid": "6b814f18-4e8f-4dc6-a472-a092ced2af22", "name": "", "x": 38.63720762179658, "y": -122.41081812238316, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2e3e10c6-6ce2-4efa-be50-80e8b9bffe29", "name": "p1rlv13195", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6b814f18-4e8f-4dc6-a472-a092ced2af22"}}}}, {"uuid": "723dc179-b0d4-453a-a37d-3602709a2654", "name": "", "x": 38.63750552004759, "y": -122.4109190928234, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2cdd7c49-e758-4009-8db5-d0b5748f919c", "name": "p1rlv13201", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "723dc179-b0d4-453a-a37d-3602709a2654"}}}}, {"uuid": "855b9038-87f7-4d5d-b419-c8e7d259873c", "name": "", "x": 38.64190459200407, "y": -122.42077252919503, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fdfa0310-7dc5-4181-a64e-cc2522370547", "name": "p1rdt6349lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "855b9038-87f7-4d5d-b419-c8e7d259873c"}}}}, {"uuid": "a02fd54c-e29a-4c35-bbfb-ae25adf08bd4", "name": "", "x": 38.6420159229094, "y": -122.42084455001161, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "268361f6-d5ac-4002-80a6-f56f3b33599c", "name": "p1rlv13189", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a02fd54c-e29a-4c35-bbfb-ae25adf08bd4"}}}}, {"uuid": "06e6e604-e32f-43a8-a8e3-cb370f644ed3", "name": "", "x": 38.636198973427064, "y": -122.41018025968964, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0138b892-d18e-497c-9857-c4d5676deac2", "name": "p1rdt6350lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "06e6e604-e32f-43a8-a8e3-cb370f644ed3"}}}}, {"uuid": "1854b823-e587-42c6-9322-3428ce6ce9b2", "name": "", "x": 38.63617297274995, "y": -122.41013766183407, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3dbc593c-3949-4fa4-8738-d92540dbf998", "name": "p1rlv13190", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1854b823-e587-42c6-9322-3428ce6ce9b2"}}}}, {"uuid": "2166852d-80a3-428b-8d53-254aa32d4239", "name": "", "x": 38.634295860150814, "y": -122.41680227142706, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "015322ae-7712-488f-9569-33fc785e4f62", "name": "p1rdt6353lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2166852d-80a3-428b-8d53-254aa32d4239"}}}}, {"uuid": "7e881470-549e-48ee-adf6-abc91359e7f6", "name": "", "x": 38.634321357711805, "y": -122.41675918344534, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2d5ba889-d8f7-44ca-86b2-40939fa95df2", "name": "p1rlv13194", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7e881470-549e-48ee-adf6-abc91359e7f6"}}}}, {"uuid": "527d288f-2043-4812-9466-eedc4d8ab423", "name": "", "x": 38.63633728483974, "y": -122.42060300525114, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0fd10fd1-b67f-422c-b976-582e2bb4e0ec", "name": "p1rdm13558", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "527d288f-2043-4812-9466-eedc4d8ab423"}}}}, {"uuid": "1dca3f46-9489-4e6b-8c7c-ebe7d8fde286", "name": "", "x": 38.63688282698339, "y": -122.41975985681357, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "27013147-3d8f-4d75-a7a7-24457dc6d62a", "name": "p1rlv13196", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1dca3f46-9489-4e6b-8c7c-ebe7d8fde286"}}}}, {"uuid": "8cc62ace-11fa-4dd3-a1d9-b50e2ad0e7a0", "name": "", "x": 38.63646127576851, "y": -122.42073591122158, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f06a08bd-05ea-4914-b0d0-07cd0e83bfbc", "name": "p1rdt6354lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8cc62ace-11fa-4dd3-a1d9-b50e2ad0e7a0"}}}}, {"uuid": "c604b145-f503-41b1-9dc4-2f31cad75e9b", "name": "", "x": 38.63663597134643, "y": -122.42086486559913, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "786efaf4-c281-4def-9a4e-2ffbf37e08be", "name": "p1rdm13559", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c604b145-f503-41b1-9dc4-2f31cad75e9b"}}}}, {"uuid": "a95d2d49-eb75-4e81-a97c-4fd013ac2e53", "name": "", "x": 38.63697733189416, "y": -122.42007329323263, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fed30a3f-12a5-4545-b5d5-5c13a131a256", "name": "p1rlv13200", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a95d2d49-eb75-4e81-a97c-4fd013ac2e53"}}}}, {"uuid": "a8acb079-e050-43db-b97d-4a7c0aed2fdf", "name": "", "x": 38.64208811872309, "y": -122.42143750947257, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f1d14a79-4d18-43fe-8790-57ea9adf83a8", "name": "p1rdt6355lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8acb079-e050-43db-b97d-4a7c0aed2fdf"}}}}, {"uuid": "ecb37bad-3593-475c-827e-ec4e7777c96f", "name": "", "x": 38.64203661805849, "y": -122.42138444352005, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7b077d0f-74ec-4a04-8eb8-cf02ad16077d", "name": "p1rlv13197", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ecb37bad-3593-475c-827e-ec4e7777c96f"}}}}, {"uuid": "76c93f4d-c02a-44ff-b4b5-6f417c2b54a4", "name": "", "x": 38.637121227961, "y": -122.41980119772418, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "548724aa-110a-428f-b71a-acdf0051dc39", "name": "p1rdt6356lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "76c93f4d-c02a-44ff-b4b5-6f417c2b54a4"}}}}, {"uuid": "a6b8ea32-a985-4859-ab59-f6d7b0d0da63", "name": "", "x": 38.6370952307597, "y": -122.41975859580664, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ad7545fb-8a41-4ed7-a178-e90f19bfa9d5", "name": "p1rlv13199", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a6b8ea32-a985-4859-ab59-f6d7b0d0da63"}}}}, {"uuid": "ddfdec26-8ee3-49e0-9a72-cb7236e92342", "name": "", "x": 38.625625701122225, "y": -122.46597233146389, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e36cfaaa-3996-4cc6-aa4f-170f20c5d1e0", "name": "p1rdt6409lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ddfdec26-8ee3-49e0-9a72-cb7236e92342"}}}}, {"uuid": "b2a436d9-b0f8-48e2-aeb6-3e0d1f57befc", "name": "", "x": 38.625599720610666, "y": -122.46592971942587, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "473b080b-1412-40dc-a452-09d43a462098", "name": "p1rlv13316", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b2a436d9-b0f8-48e2-aeb6-3e0d1f57befc"}}}}, {"uuid": "0b946f90-2e39-4fd3-b0ba-8544c409d55c", "name": "", "x": 38.578857638178405, "y": -122.51077785799649, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7", "name": "p1rdt6498lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0b946f90-2e39-4fd3-b0ba-8544c409d55c"}}}}, {"uuid": "1d821ba2-72a7-4d64-b2d1-a334142c0759", "name": "", "x": 38.57893830123369, "y": -122.5108886242969, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "353889fb-da44-4cf8-ae0e-d20541f36d7e", "name": "p1rlv13597", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d821ba2-72a7-4d64-b2d1-a334142c0759"}}}}, {"uuid": "467c88e4-d134-4fa8-9e81-73a5a3be69ab", "name": "", "x": 38.57885671632947, "y": -122.51077437155158, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6015a810-79da-480f-b1a1-fd6a4abdba37", "name": "p1rlv13631", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "467c88e4-d134-4fa8-9e81-73a5a3be69ab"}}}}, {"uuid": "d9c52a80-2697-4d5e-914c-a915bfd7285f", "name": "", "x": 38.579117623107756, "y": -122.51066927591476, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f92273c9-90b8-4819-b036-9d69afb5aed6", "name": "p1rlv13696", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d9c52a80-2697-4d5e-914c-a915bfd7285f"}}}}, {"uuid": "b7b04bac-1b23-4b18-bc24-f9ee42054770", "name": "", "x": 38.57882896139523, "y": -122.51060235083729, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1fe3c958-296f-4b51-8b2b-74bb34ddb5a6", "name": "p1rlv13702", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b7b04bac-1b23-4b18-bc24-f9ee42054770"}}}}, {"uuid": "9aaf3362-751e-4e7d-ab80-e0243d0b72f8", "name": "", "x": 38.578814411150496, "y": -122.51075566702022, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c9efacf5-5b96-4670-b6f1-dc398485cde9", "name": "p1rlv13703", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9aaf3362-751e-4e7d-ab80-e0243d0b72f8"}}}}, {"uuid": "1d16ca37-4d9e-4caa-adb7-d56ca9da816a", "name": "", "x": 38.57878534253772, "y": -122.51094706458596, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "457c6c9d-5020-4cf3-9c1e-c36012a619d2", "name": "p1rlv13724", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d16ca37-4d9e-4caa-adb7-d56ca9da816a"}}}}, {"uuid": "8390b3b1-225b-4c6a-896a-3fb330512d9c", "name": "", "x": 38.58016810697636, "y": -122.51189059526916, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ce39f1f5-b784-4919-9d3d-f6149f39595e", "name": "p1rdm13996", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8390b3b1-225b-4c6a-896a-3fb330512d9c"}}}}, {"uuid": "7d953cf8-edae-40e4-91a0-6f7cb240f34b", "name": "", "x": 38.5798974214499, "y": -122.5118120619195, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "59953c2f-244e-4bb8-ab24-b28d82b195e1", "name": "p1rlv13598", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7d953cf8-edae-40e4-91a0-6f7cb240f34b"}}}}, {"uuid": "93963b59-7c3d-4dd6-ac3e-0ad59a026255", "name": "", "x": 38.57980967492142, "y": -122.51170181808382, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aeea20e0-9908-4f28-aa5d-068244e3861b", "name": "p1rlv13626", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "93963b59-7c3d-4dd6-ac3e-0ad59a026255"}}}}, {"uuid": "1ad6b39f-4277-41f1-9a59-2045f78b2e42", "name": "", "x": 38.57989689465763, "y": -122.51168577702153, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cc33013a-6a90-46a7-9127-f32288111c14", "name": "p1rlv13635", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1ad6b39f-4277-41f1-9a59-2045f78b2e42"}}}}, {"uuid": "5eeeb5e6-f8c4-4529-a6ba-bfc863eb4f1e", "name": "", "x": 38.579743504522455, "y": -122.51164089263591, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7b3e7495-7732-42ce-8d53-a5f1b7383ce4", "name": "p1rlv20504", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5eeeb5e6-f8c4-4529-a6ba-bfc863eb4f1e"}}}}, {"uuid": "c3a02a5e-5c58-4beb-a733-0ec716c360ff", "name": "", "x": 38.5802287989983, "y": -122.5117616084684, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bb05d831-1556-4f56-8065-d9d16657caa3", "name": "p1rdt6499lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c3a02a5e-5c58-4beb-a733-0ec716c360ff"}}}}, {"uuid": "a99ef52b-4365-4bea-9c0d-269b26323d76", "name": "", "x": 38.58030555227583, "y": -122.51158054354175, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f85240e6-bbbe-4b90-8419-a00a3ca9613f", "name": "p1rdm13999", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a99ef52b-4365-4bea-9c0d-269b26323d76"}}}}, {"uuid": "3faf2268-1c3c-4bf5-bd88-7c9001bd6c12", "name": "", "x": 38.57988706857757, "y": -122.51149067050049, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3839c291-3f45-46c3-973f-6a9615fcf81b", "name": "p1rlv13698", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3faf2268-1c3c-4bf5-bd88-7c9001bd6c12"}}}}, {"uuid": "149c7dea-71cc-4482-83fc-8194d3d50a88", "name": "", "x": 38.58035293960693, "y": -122.51140410649425, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ea740eb8-42c6-4417-97d6-7c73f1fc2bc8", "name": "p1rdm14000", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "149c7dea-71cc-4482-83fc-8194d3d50a88"}}}}, {"uuid": "108611d9-9d63-47a3-aae9-ef2cdacf6787", "name": "", "x": 38.580220356921046, "y": -122.5114539704366, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "642597e6-fe60-442f-b356-2be6f21677b2", "name": "p1rlv13726", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "108611d9-9d63-47a3-aae9-ef2cdacf6787"}}}}, {"uuid": "17774d75-030e-4f6b-b9fc-a5ea4e90bb77", "name": "", "x": 38.58083948102145, "y": -122.5097420033343, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a20a4242-8a76-49f3-9bf5-3d7aaf751cdc", "name": "p1rdt6500lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "17774d75-030e-4f6b-b9fc-a5ea4e90bb77"}}}}, {"uuid": "fca68e74-8079-476d-8e08-9403ecc91752", "name": "", "x": 38.58075318348773, "y": -122.50956749241811, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "216537dd-ea7b-461c-b821-99491c41b7f0", "name": "p1rlv13613", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fca68e74-8079-476d-8e08-9403ecc91752"}}}}, {"uuid": "946b4384-4111-4b9d-baa0-3d02c5634209", "name": "", "x": 38.58094565510626, "y": -122.50948667802179, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "83aa4266-e486-4e00-a09b-7bcdc613a9b5", "name": "p1rdm14004", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "946b4384-4111-4b9d-baa0-3d02c5634209"}}}}, {"uuid": "98f2af76-03e7-4ca3-8482-85d5bb432b8c", "name": "", "x": 38.580815639747385, "y": -122.50941781578797, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f823a90c-effd-489c-9e0a-c110ccb7b9e8", "name": "p1rlv13618", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "98f2af76-03e7-4ca3-8482-85d5bb432b8c"}}}}, {"uuid": "273b3d0e-7740-4807-828e-a1e37aa9d0e9", "name": "", "x": 38.58094199565767, "y": -122.50946287997223, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ff282b99-30bb-4c1d-acb9-02fafe241577", "name": "p1rdm14007", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "273b3d0e-7740-4807-828e-a1e37aa9d0e9"}}}}, {"uuid": "43d3fb88-4440-485a-a7d4-1cfa651312fb", "name": "", "x": 38.580561868772826, "y": -122.50907511585717, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1c61a243-7736-46a0-a950-7cc811381158", "name": "p1rlv13653", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "43d3fb88-4440-485a-a7d4-1cfa651312fb"}}}}, {"uuid": "57b109ad-77d4-4e35-8c6a-2d1b67884755", "name": "", "x": 38.58103524253283, "y": -122.50935977822509, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3c0ae3b1-ac0d-43c9-9a1e-c73bd10e3ad8", "name": "p1rdm14002", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "57b109ad-77d4-4e35-8c6a-2d1b67884755"}}}}, {"uuid": "974a1a48-d33c-48aa-aeb5-230ce3105a1c", "name": "", "x": 38.58069699573112, "y": -122.50906271510544, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d2a60818-4310-4100-9aa8-35ef37aa5f40", "name": "p1rlv13599", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "974a1a48-d33c-48aa-aeb5-230ce3105a1c"}}}}, {"uuid": "fabd8bb6-7edf-42be-8e6b-5663ec1f9863", "name": "", "x": 38.58115055848325, "y": -122.50921129101727, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d576dffc-af75-488e-8c51-19aa726f0505", "name": "p1rdm14005", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fabd8bb6-7edf-42be-8e6b-5663ec1f9863"}}}}, {"uuid": "631cb3f9-1cef-4bac-96dc-ab0058dd06c9", "name": "", "x": 38.58066046743406, "y": -122.50894815487301, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "62a29ac5-7227-43b2-b602-b1189cc93839", "name": "p1rlv13648", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "631cb3f9-1cef-4bac-96dc-ab0058dd06c9"}}}}, {"uuid": "e50ab3f8-8db4-47ab-851d-95ec1d4566e7", "name": "", "x": 38.58075404919642, "y": -122.50977414282289, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7e5abf33-75a2-446f-9c6c-1f3384b78c24", "name": "p1rdm14008", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e50ab3f8-8db4-47ab-851d-95ec1d4566e7"}}}}, {"uuid": "45f7226f-8189-4fdd-986c-9f3171a508b2", "name": "", "x": 38.58080831157611, "y": -122.50981969761952, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4671f981-e26e-4f26-9698-7f9068ce6dec", "name": "p1rlv13687", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "45f7226f-8189-4fdd-986c-9f3171a508b2"}}}}, {"uuid": "4690aac7-835d-4f30-ae06-41a51aaf2b24", "name": "", "x": 38.580709327387154, "y": -122.50985481311328, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "592b8095-ba99-4993-a445-9af51fa89f57", "name": "p1rdm14009", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4690aac7-835d-4f30-ae06-41a51aaf2b24"}}}}, {"uuid": "c77d28e1-b011-4ecc-a915-17583b1adf98", "name": "", "x": 38.580745614457776, "y": -122.50991197100555, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "44aa3f37-e0db-4050-b47f-ac14b7fa6534", "name": "p1rlv13719", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c77d28e1-b011-4ecc-a915-17583b1adf98"}}}}, {"uuid": "810ea90d-e32b-4403-a753-626d87d2255b", "name": "", "x": 38.58065559384605, "y": -122.50993554454202, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33445b16-68bf-4606-8ac5-def4763fb95d", "name": "p1rdm14006", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "810ea90d-e32b-4403-a753-626d87d2255b"}}}}, {"uuid": "8cb81b56-81c0-4541-bf0e-8d99301e93e7", "name": "", "x": 38.58069192894027, "y": -122.51000418300181, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3310c14a-d1ee-4d0c-8428-d002703c61d5", "name": "p1rlv13652", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8cb81b56-81c0-4541-bf0e-8d99301e93e7"}}}}, {"uuid": "d5eb11ec-20a7-43a6-bcbe-8e80506573b5", "name": "", "x": 38.580115053283016, "y": -122.51211138251598, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923", "name": "p1rdt6501lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d5eb11ec-20a7-43a6-bcbe-8e80506573b5"}}}}, {"uuid": "e0c5a120-ac0a-43a9-80c0-9d910c4b0d14", "name": "", "x": 38.57996098198724, "y": -122.5119264394613, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "59ab6d81-a91c-4350-8f94-abe02e3e1555", "name": "p1rlv13600", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e0c5a120-ac0a-43a9-80c0-9d910c4b0d14"}}}}, {"uuid": "c9ff9645-8f59-4b3a-b2b6-f8365fc0a052", "name": "", "x": 38.58025012153835, "y": -122.51210817586814, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "29838633-5c95-4b73-8227-cfa7f4aedc32", "name": "p1rlv13606", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c9ff9645-8f59-4b3a-b2b6-f8365fc0a052"}}}}, {"uuid": "b28ac41e-68ec-478f-8f63-b7474b7cb521", "name": "", "x": 38.58018699193046, "y": -122.51209712213534, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a5e8caf4-4d81-4bbd-98df-6622c5ad0563", "name": "p1rlv13608", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b28ac41e-68ec-478f-8f63-b7474b7cb521"}}}}, {"uuid": "a75547f7-63ae-4c46-88ef-c390878cd28c", "name": "", "x": 38.580430450820984, "y": -122.5121299176103, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f693a1d2-5499-4810-9458-f205eda265fa", "name": "p1rlv13619", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a75547f7-63ae-4c46-88ef-c390878cd28c"}}}}, {"uuid": "36b4f113-3755-49cf-8d87-c2a79648b0d1", "name": "", "x": 38.58039473905232, "y": -122.51221052513978, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4540b2cb-ee21-4515-a7ca-fbca371f060d", "name": "p1rlv13622", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "36b4f113-3755-49cf-8d87-c2a79648b0d1"}}}}, {"uuid": "b1b116f3-0151-42b2-a8aa-ac02307e8906", "name": "", "x": 38.57999120125346, "y": -122.51201057019674, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "30c470ac-39d1-4379-9ae7-790d912bce2c", "name": "p1rlv13637", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b1b116f3-0151-42b2-a8aa-ac02307e8906"}}}}, {"uuid": "0870751c-5e1a-47c1-ab38-434e9da36a6c", "name": "", "x": 38.580262816627275, "y": -122.51171636414, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0b7d4c6f-98b5-4cec-b8a4-9311b5fc92bd", "name": "p1rdm14016", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0870751c-5e1a-47c1-ab38-434e9da36a6c"}}}}, {"uuid": "1221665c-1324-49ea-93f7-2780a566c268", "name": "", "x": 38.58050168270344, "y": -122.5119227801456, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "de45dc59-3e0a-4b33-8cf4-d5213b0140c1", "name": "p1rlv13683", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1221665c-1324-49ea-93f7-2780a566c268"}}}}, {"uuid": "16be71f9-5715-4ab6-8469-27d24af8c118", "name": "", "x": 38.58090324022768, "y": -122.51898480487121, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7682e9f7-1272-4781-b128-34c7329afe49", "name": "p1rdt6502lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "16be71f9-5715-4ab6-8469-27d24af8c118"}}}}, {"uuid": "a8cffd85-3289-411b-aba3-fe19b3957850", "name": "", "x": 38.5809550747074, "y": -122.51912974155378, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "91953a27-bbc7-494a-bec2-a12b4c0f6af6", "name": "p1rlv13601", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8cffd85-3289-411b-aba3-fe19b3957850"}}}}, {"uuid": "d1656f14-981b-475f-950b-06cfa738b307", "name": "", "x": 38.580818625476454, "y": -122.51882066658119, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "987b05d5-9bb9-434d-98b3-623ee5014870", "name": "p1rlv13634", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1656f14-981b-475f-950b-06cfa738b307"}}}}, {"uuid": "576e3987-1203-4abc-b2aa-d321607a4c09", "name": "", "x": 38.579472359669175, "y": -122.51077416509521, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "387e7785-8d40-4ddd-8c2b-14a83d4e7401", "name": "p1rdt6505lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "576e3987-1203-4abc-b2aa-d321607a4c09"}}}}, {"uuid": "117edca2-b846-4d13-9e09-6fbfb439c0a0", "name": "", "x": 38.579542563399, "y": -122.5109993333898, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c9b83bdf-b564-4997-bfc7-1be2f2e58199", "name": "p1rlv13604", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "117edca2-b846-4d13-9e09-6fbfb439c0a0"}}}}, {"uuid": "ee47ad29-c529-4e7b-a7dd-b2020a1a2885", "name": "", "x": 38.579306628363845, "y": -122.51061059015836, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c39dc6f1-08b5-4bc1-a6ae-be0076af56aa", "name": "p1rlv13605", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ee47ad29-c529-4e7b-a7dd-b2020a1a2885"}}}}, {"uuid": "0dec7af5-bd71-4eb9-b72c-26a08ebea42c", "name": "", "x": 38.57932426767413, "y": -122.51051862504016, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a7be734c-88e2-42c1-8061-f4632bd05759", "name": "p1rlv13654", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0dec7af5-bd71-4eb9-b72c-26a08ebea42c"}}}}, {"uuid": "2116346b-bc4a-4280-8b61-ba47b65fca49", "name": "", "x": 38.57968631853392, "y": -122.51089503204967, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8df1a69e-5b18-4eef-ab60-543a97257297", "name": "p1rlv13676", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2116346b-bc4a-4280-8b61-ba47b65fca49"}}}}, {"uuid": "e3d45cb8-548e-48b2-8d6b-213cd2b0dc2e", "name": "", "x": 38.579406764605274, "y": -122.51085100517132, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a822fdb0-b531-49b0-89da-b517e5ae6e3a", "name": "p1rlv13715", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e3d45cb8-548e-48b2-8d6b-213cd2b0dc2e"}}}}, {"uuid": "b166c449-a23e-4a12-b4cc-82d2661db536", "name": "", "x": 38.57531283222509, "y": -122.51744138284937, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f5844baa-5e0f-4edd-9122-fe4255adad0b", "name": "p1rdt6507lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b166c449-a23e-4a12-b4cc-82d2661db536"}}}}, {"uuid": "5eb22c70-3464-4dba-a0ef-ad656df3001f", "name": "", "x": 38.57505206910961, "y": -122.5168960568265, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "17d92377-b4f1-4194-89cd-130bddb9b77c", "name": "p1rlv13610", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5eb22c70-3464-4dba-a0ef-ad656df3001f"}}}}, {"uuid": "09e5d099-7b4a-4e2d-b26a-9262b490061d", "name": "", "x": 38.57545948963316, "y": -122.51735253068708, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5a2f5fad-c0a9-4f62-a318-ef00c0d4f470", "name": "p1rdm14031", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "09e5d099-7b4a-4e2d-b26a-9262b490061d"}}}}, {"uuid": "143b6497-07f4-4643-9cde-7468e190cad4", "name": "", "x": 38.57508745244601, "y": -122.5167350997636, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e5ab8bce-7c02-4c7b-962e-3fb44a3ab7a9", "name": "p1rlv13712", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "143b6497-07f4-4643-9cde-7468e190cad4"}}}}, {"uuid": "90a1cfbd-701d-4453-a895-51357736c657", "name": "", "x": 38.58028384394968, "y": -122.51110778698562, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5", "name": "p1rdt6508lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "90a1cfbd-701d-4453-a895-51357736c657"}}}}, {"uuid": "86ae937a-a60c-4ae1-a7c8-387f40e1eb91", "name": "", "x": 38.58035447758333, "y": -122.51120048333938, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "630b2a63-622f-4f78-8390-77c69ba7e393", "name": "p1rlv13611", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "86ae937a-a60c-4ae1-a7c8-387f40e1eb91"}}}}, {"uuid": "56eecfee-9e33-4531-a77b-2f2f7c11b0b4", "name": "", "x": 38.58037206939203, "y": -122.51109703650175, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5868c24b-2a58-459b-8650-a6072241aca8", "name": "p1rlv13666", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "56eecfee-9e33-4531-a77b-2f2f7c11b0b4"}}}}, {"uuid": "061c6dbf-e40a-4035-a3a4-ba8cb2fe1a04", "name": "", "x": 38.57994856849807, "y": -122.51111138826255, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f777bc74-e6f3-4e80-bb72-0764964db21e", "name": "p1rlv13685", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "061c6dbf-e40a-4035-a3a4-ba8cb2fe1a04"}}}}, {"uuid": "f562c711-b88d-409b-8e2e-eb3672b70456", "name": "", "x": 38.58024590590882, "y": -122.51109789179142, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aa7a324e-d367-49a5-820a-b18e72243265", "name": "p1rlv13701", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f562c711-b88d-409b-8e2e-eb3672b70456"}}}}, {"uuid": "2d927b29-01ab-4d50-a650-33eccd1a79d9", "name": "", "x": 38.5799747881709, "y": -122.51091603723427, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "286623b3-af08-4a60-896a-1f5b85fe04a5", "name": "p1rlv13707", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2d927b29-01ab-4d50-a650-33eccd1a79d9"}}}}, {"uuid": "063db81f-f1ad-43f7-88ab-eff9687a417b", "name": "", "x": 38.58041348455226, "y": -122.51100123505434, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "572123ef-d255-42a9-9c61-95d99aaff775", "name": "p1rdm14033", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "063db81f-f1ad-43f7-88ab-eff9687a417b"}}}}, {"uuid": "61501da2-c1a2-4b94-b083-88cfce749eb4", "name": "", "x": 38.58026296994941, "y": -122.51086815956218, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c808261e-a49e-4954-bdc4-a8b63d0ee25b", "name": "p1rlv13651", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "61501da2-c1a2-4b94-b083-88cfce749eb4"}}}}, {"uuid": "4b2e985c-70d7-4dd4-a2d1-1e17ef074d29", "name": "", "x": 38.58047071823679, "y": -122.5109815591307, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9657a993-0005-4ffc-8c9f-18e80a491070", "name": "p1rlv13728", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4b2e985c-70d7-4dd4-a2d1-1e17ef074d29"}}}}, {"uuid": "b204f9a6-7874-4654-b240-9f95ec20a3a3", "name": "", "x": 38.5802039677474, "y": -122.51142297137118, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f817a28f-c650-4eb4-84c0-751fe5053c75", "name": "p1rdt6509lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b204f9a6-7874-4654-b240-9f95ec20a3a3"}}}}, {"uuid": "3d63084b-d34f-45cc-acbb-fd7c7f5a12e0", "name": "", "x": 38.58031071328429, "y": -122.51151076251458, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6eda3e97-a618-41ab-ae55-ba67f6bb0234", "name": "p1rlv13612", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3d63084b-d34f-45cc-acbb-fd7c7f5a12e0"}}}}, {"uuid": "6497e293-e1f6-435a-bce1-81d85ff0cc34", "name": "", "x": 38.58038280670725, "y": -122.51151027418985, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e47df44a-79f1-423b-a295-c9c354795895", "name": "p1rlv13628", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6497e293-e1f6-435a-bce1-81d85ff0cc34"}}}}, {"uuid": "1c58cbeb-4ec0-4ca2-ac37-c2b219acb7ac", "name": "", "x": 38.58025300210597, "y": -122.51162119713781, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b65a5fd-f38e-447a-a51a-e7a214ba6bcc", "name": "p1rdm14041", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1c58cbeb-4ec0-4ca2-ac37-c2b219acb7ac"}}}}, {"uuid": "fde75755-8187-4131-a5d4-4019004aa484", "name": "", "x": 38.580112887543876, "y": -122.51161542971188, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3bd69c55-2141-4c8e-becf-efa4bff8a63e", "name": "p1rlv13627", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fde75755-8187-4131-a5d4-4019004aa484"}}}}, {"uuid": "e4998f27-5b4d-4c16-ab05-f4dac5151539", "name": "", "x": 38.580175969292135, "y": -122.51161500252242, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "122e0772-7de6-4117-b1d3-caafbbbc8e22", "name": "p1rlv13659", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e4998f27-5b4d-4c16-ab05-f4dac5151539"}}}}, {"uuid": "b4d08695-c287-4103-a10a-c5f5e7de9242", "name": "", "x": 38.58035042352862, "y": -122.51170963762122, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3d6fd13-2f04-4f23-97a3-cdf99159174c", "name": "p1rlv13660", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b4d08695-c287-4103-a10a-c5f5e7de9242"}}}}, {"uuid": "d88a5ec5-7a6d-401d-9412-e96155fdde62", "name": "", "x": 38.58048939096295, "y": -122.51181556577525, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f9aa7e62-8974-4ef0-aa5a-bcd545245aea", "name": "p1rlv13677", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d88a5ec5-7a6d-401d-9412-e96155fdde62"}}}}, {"uuid": "75d80de5-97ee-4db0-a01b-be74d82659b4", "name": "", "x": 38.58024561739162, "y": -122.51180603102428, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1252c522-5ced-4f4c-908c-f58501ad6f92", "name": "p1rdm14040", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "75d80de5-97ee-4db0-a01b-be74d82659b4"}}}}, {"uuid": "72b5ddf0-cdde-4895-9453-c7f24c784a2d", "name": "", "x": 38.580128349144296, "y": -122.51168024007933, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a5746d1-24a6-4ae4-b5dc-cef23b56660d", "name": "p1rlv13624", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "72b5ddf0-cdde-4895-9453-c7f24c784a2d"}}}}, {"uuid": "bd429e21-2c9a-44b9-8545-365dc7b0f4b3", "name": "", "x": 38.580312054434806, "y": -122.51183221682473, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6097c903-70fc-4635-a66c-fee2243ba545", "name": "p1rlv13721", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bd429e21-2c9a-44b9-8545-365dc7b0f4b3"}}}}, {"uuid": "8afa5cca-cf73-4ba5-8115-0096b37ddc9f", "name": "", "x": 38.580296766700286, "y": -122.51131091827517, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9be8942c-8459-4c1d-a3b0-a89ee5cced4e", "name": "p1rdm14043", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8afa5cca-cf73-4ba5-8115-0096b37ddc9f"}}}}, {"uuid": "29f2bebe-42ef-47a3-a9af-271923a11423", "name": "", "x": 38.5799938666379, "y": -122.51116848511225, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2b3fe33f-fdcf-42f5-be08-8da15a4d4958", "name": "p1rlv13633", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "29f2bebe-42ef-47a3-a9af-271923a11423"}}}}, {"uuid": "c53689db-2b77-4c25-b14e-1fb5d913ade2", "name": "", "x": 38.5799041333983, "y": -122.51126093949996, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "54887ca7-ae23-42d0-a715-aed8baa38ade", "name": "p1rlv13663", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c53689db-2b77-4c25-b14e-1fb5d913ade2"}}}}, {"uuid": "9ab32b8a-c150-4705-a799-5d52c7489517", "name": "", "x": 38.580282671809215, "y": -122.5112698550077, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32bec8ad-b312-4502-a2a1-6a4c9b2dd87a", "name": "p1rlv13672", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9ab32b8a-c150-4705-a799-5d52c7489517"}}}}, {"uuid": "36454f81-98b1-4198-a09a-d38e5d78e1a2", "name": "", "x": 38.58020166258251, "y": -122.51129336562714, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60fe0a16-aa4d-4fe8-9f39-81bfa13b505f", "name": "p1rlv13686", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "36454f81-98b1-4198-a09a-d38e5d78e1a2"}}}}, {"uuid": "0a18e2cb-16df-4c1c-81b6-dbb05c76fbe1", "name": "", "x": 38.57904493503404, "y": -122.51120538916284, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5d62fe3b-7644-46d1-8a15-e86d95ae8b2a", "name": "p1rdt6510lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a18e2cb-16df-4c1c-81b6-dbb05c76fbe1"}}}}, {"uuid": "f3325332-f006-4607-a16a-4f00a69b75f0", "name": "", "x": 38.5789032137621, "y": -122.51111847447159, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3de8b994-01ba-4eae-b9cf-7fb174d32355", "name": "p1rlv13614", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f3325332-f006-4607-a16a-4f00a69b75f0"}}}}, {"uuid": "ba7db288-60ce-4c65-a595-a56e7f503a45", "name": "", "x": 38.5791652716089, "y": -122.51128890787042, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "85b910cd-def8-41d8-ad47-3c074a54ad8d", "name": "p1rlv13680", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ba7db288-60ce-4c65-a595-a56e7f503a45"}}}}, {"uuid": "82223b46-a986-42df-938c-4dbe70b435f8", "name": "", "x": 38.57913785305847, "y": -122.51119724847887, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "58e2b774-ac04-435e-9e03-573b3aa94cfb", "name": "p1rlv20467", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "82223b46-a986-42df-938c-4dbe70b435f8"}}}}, {"uuid": "50b458e0-d55c-4e4a-843a-96e5759c930a", "name": "", "x": 38.58046789565426, "y": -122.5107496740826, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5702c88a-92e4-40ce-8a51-684fe6662789", "name": "p1rdt6512lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "50b458e0-d55c-4e4a-843a-96e5759c930a"}}}}, {"uuid": "cd9c9ac2-fe35-4dc5-99b4-d2982e164998", "name": "", "x": 38.58036118662805, "y": -122.51064935740038, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "850d5b69-14cf-4a18-8cb0-4f1b3033b0aa", "name": "p1rlv13616", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cd9c9ac2-fe35-4dc5-99b4-d2982e164998"}}}}, {"uuid": "3ebbb7c2-14b8-4efd-a122-9e8fedbeb88b", "name": "", "x": 38.58035246292223, "y": -122.510718301644, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "20009de0-cbe7-4b4f-a046-425a6ae71925", "name": "p1rlv13643", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3ebbb7c2-14b8-4efd-a122-9e8fedbeb88b"}}}}, {"uuid": "4bb71e49-0e3e-4855-95cd-ac756bef5eca", "name": "", "x": 38.58049679372011, "y": -122.51075176502394, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3fe0466e-cce5-4c6c-b13f-cedd349b6944", "name": "p1rlv13646", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4bb71e49-0e3e-4855-95cd-ac756bef5eca"}}}}, {"uuid": "6c71be1f-dd4f-4c0a-9aba-36a2ddb80c23", "name": "", "x": 38.5801239858384, "y": -122.51063551633443, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3fa2041e-34c4-4f1f-a329-74969c3da75f", "name": "p1rlv13650", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c71be1f-dd4f-4c0a-9aba-36a2ddb80c23"}}}}, {"uuid": "26581ec2-f996-4c6a-944b-6969311a7b5b", "name": "", "x": 38.580207508083255, "y": -122.510535591989, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e290046b-c936-4f51-b4ef-632bf572ab7f", "name": "p1rlv13725", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "26581ec2-f996-4c6a-944b-6969311a7b5b"}}}}, {"uuid": "91b7f1e8-60ef-4282-9431-17ad4a4ed438", "name": "", "x": 38.580513953094915, "y": -122.51054499300294, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e3ed4387-9ecb-43c4-a392-e72bc5cb32b6", "name": "p1rdm14062", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "91b7f1e8-60ef-4282-9431-17ad4a4ed438"}}}}, {"uuid": "bff6a849-e000-42dd-a1ca-7d6cef0fe830", "name": "", "x": 38.580216231682456, "y": -122.51046664786318, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "70cf02cc-8f1b-48ab-b9e6-50c3e58ad9ae", "name": "p1rlv13664", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bff6a849-e000-42dd-a1ca-7d6cef0fe830"}}}}, {"uuid": "5fd72616-7318-4cb3-8643-7fa32865504e", "name": "", "x": 38.58042383633111, "y": -122.5105456046176, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60f08cde-51d3-4b51-9ab5-b61c8043950f", "name": "p1rlv13681", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5fd72616-7318-4cb3-8643-7fa32865504e"}}}}, {"uuid": "55257008-f143-4a2f-b906-8ce95b1b534f", "name": "", "x": 38.58052339680616, "y": -122.51064825672786, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fdbfe616-f51f-416a-94ce-6e676d300226", "name": "p1rlv13717", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "55257008-f143-4a2f-b906-8ce95b1b534f"}}}}, {"uuid": "23176e93-7407-464d-bc9a-52c55cf5818d", "name": "", "x": 38.5805590114763, "y": -122.5105446871946, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0fe37b51-0258-4812-9d96-3cc28c4bd55b", "name": "p1rlv20509", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "23176e93-7407-464d-bc9a-52c55cf5818d"}}}}, {"uuid": "ec46f3c7-03e2-4c29-94a5-0dc5d4fb3c9f", "name": "", "x": 38.580430683168224, "y": -122.51091156777555, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "485928ba-ff70-4be2-89ff-721ff82269fb", "name": "p1rdm14063", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ec46f3c7-03e2-4c29-94a5-0dc5d4fb3c9f"}}}}, {"uuid": "e216cc59-9ec4-4e42-9d09-5a00f7118d8d", "name": "", "x": 38.580046353830355, "y": -122.51078926317813, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b2f95b8b-190c-4df2-9dd2-daee5efde34b", "name": "p1rlv13671", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e216cc59-9ec4-4e42-9d09-5a00f7118d8d"}}}}, {"uuid": "248a8ebb-00ae-4a38-8a4f-10d10e9c56ef", "name": "", "x": 38.5800731009349, "y": -122.51072019695825, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "17936036-1191-4f91-bc12-2298db7b77e3", "name": "p1rlv13714", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "248a8ebb-00ae-4a38-8a4f-10d10e9c56ef"}}}}, {"uuid": "5aa22a9c-1ce1-4621-93e7-b53b9e38c72c", "name": "", "x": 38.580347829371135, "y": -122.51152987084961, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ad6bef77-8f39-43b4-b2d7-58aa6e45a60b", "name": "p1rdt6514lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5aa22a9c-1ce1-4621-93e7-b53b9e38c72c"}}}}, {"uuid": "10a7ab33-dca2-44a2-bc4d-09ca6dbebcfa", "name": "", "x": 38.57949879960493, "y": -122.51130960918293, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "80f60ab3-722f-4765-8b91-4fd0196171d7", "name": "p1rlv13623", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10a7ab33-dca2-44a2-bc4d-09ca6dbebcfa"}}}}, {"uuid": "ab4f132b-fd01-4949-81d2-a31a140fcc7e", "name": "", "x": 38.57935703047459, "y": -122.51121121339025, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bb3b4207-12ad-46e6-b4de-59149a46f8a1", "name": "p1rlv13716", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ab4f132b-fd01-4949-81d2-a31a140fcc7e"}}}}, {"uuid": "eefb9220-0cb8-4f72-885d-44b3115ed714", "name": "", "x": 38.58034931676033, "y": -122.51127026442917, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "395dac73-8fae-4718-a28c-191a76a298f2", "name": "p1rdm14072", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eefb9220-0cb8-4f72-885d-44b3115ed714"}}}}, {"uuid": "f49e9feb-241d-4ae8-a52f-be30473ffb53", "name": "", "x": 38.57957036570457, "y": -122.51118283635456, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "653bdc0d-5b21-4640-861b-b88ddb5c651a", "name": "p1rlv13640", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f49e9feb-241d-4ae8-a52f-be30473ffb53"}}}}, {"uuid": "31dfa6e7-23d1-4264-b514-b8738ffa1920", "name": "", "x": 38.58109531398495, "y": -122.50927974477071, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b92f8bcd-91ce-42bd-be69-0b43cb9d4122", "name": "p1rdt6515lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "31dfa6e7-23d1-4264-b514-b8738ffa1920"}}}}, {"uuid": "67a2a8dc-35a0-49b1-85b2-43530b524e93", "name": "", "x": 38.580433778313484, "y": -122.50861675365525, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4c667408-52a0-4258-8e93-557c94520a1e", "name": "p1rlv13625", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "67a2a8dc-35a0-49b1-85b2-43530b524e93"}}}}, {"uuid": "d632ea7f-fd46-4991-a3bf-ed80f588f4d9", "name": "", "x": 38.58052341301346, "y": -122.50850133423494, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7538ab85-10b4-4f60-98f8-179e954173b0", "name": "p1rlv19156", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d632ea7f-fd46-4991-a3bf-ed80f588f4d9"}}}}, {"uuid": "06e2a999-5f7e-46c8-bf9b-88a07f0a6653", "name": "", "x": 38.58046037950707, "y": -122.50851324468255, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fed6fcd4-3c97-4f62-a1a7-0b66394218e1", "name": "p1rlv19163", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "06e2a999-5f7e-46c8-bf9b-88a07f0a6653"}}}}, {"uuid": "df7ea0fc-8400-41d7-97a9-b5124ecf0dbb", "name": "", "x": 38.580379081602544, "y": -122.50846787535407, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ebd10471-ab4c-4cb7-a822-a83ef20e9854", "name": "p1rlv19165", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "df7ea0fc-8400-41d7-97a9-b5124ecf0dbb"}}}}, {"uuid": "71c50c0a-c945-48cf-90f3-ca1f580683fc", "name": "", "x": 38.58118341315065, "y": -122.50918052803313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c2659bd3-f6ca-4d74-87c8-f92596986cb5", "name": "p1rdm14075", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "71c50c0a-c945-48cf-90f3-ca1f580683fc"}}}}, {"uuid": "2943ec98-4018-405c-ac02-33c2cd62a6ce", "name": "", "x": 38.58079429345362, "y": -122.50862577812117, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1acad56e-b6d6-4fa7-a925-f242c1558eef", "name": "p1rlv13645", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2943ec98-4018-405c-ac02-33c2cd62a6ce"}}}}, {"uuid": "a3f4101a-c9ca-45b8-ab85-d07e7ec45422", "name": "", "x": 38.57910373167705, "y": -122.51042872774359, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "119a8559-8e6c-4314-9bbd-37ef3adde415", "name": "p1rdt6516lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a3f4101a-c9ca-45b8-ab85-d07e7ec45422"}}}}, {"uuid": "8578e75a-d652-46c2-a395-6865bcbad53c", "name": "", "x": 38.579216271561, "y": -122.51055379999012, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b4358536-b06f-486d-b336-3a8576b428d0", "name": "p1rlv13629", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8578e75a-d652-46c2-a395-6865bcbad53c"}}}}, {"uuid": "8432571b-e34a-43d5-9e64-26876c6c1f96", "name": "", "x": 38.57907136448223, "y": -122.51038257383402, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "db3908f7-94f5-43a7-a3de-1f6c9b72ebd4", "name": "p1rlv13638", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8432571b-e34a-43d5-9e64-26876c6c1f96"}}}}, {"uuid": "fc5a608f-136d-45a3-b9d3-55b3b6c1f5d9", "name": "", "x": 38.57899879076654, "y": -122.51026826026441, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "091b545a-eb31-4bea-a0a6-5aa9c7a8397f", "name": "p1rlv13692", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fc5a608f-136d-45a3-b9d3-55b3b6c1f5d9"}}}}, {"uuid": "40f54f9d-097d-45d1-a5d8-f1a1f6a5fc6b", "name": "", "x": 38.579225763250356, "y": -122.51066854219654, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5a230534-6927-4af8-ba54-6ab4c9c32d21", "name": "p1rlv13708", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "40f54f9d-097d-45d1-a5d8-f1a1f6a5fc6b"}}}}, {"uuid": "7af31148-260a-4af0-929e-efbf262969e1", "name": "", "x": 38.578028811911885, "y": -122.51471027861992, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5783bae9-2c74-473f-bf18-db40bc975409", "name": "p1rdt6517lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7af31148-260a-4af0-929e-efbf262969e1"}}}}, {"uuid": "44e91cd6-7c3b-4399-82ed-b6d033f98399", "name": "", "x": 38.577889883003294, "y": -122.51448911519815, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f474e4ba-6300-4014-afe9-c245e08cf3c5", "name": "p1rlv13630", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "44e91cd6-7c3b-4399-82ed-b6d033f98399"}}}}, {"uuid": "7bdf2223-6574-4b58-aadb-d8e61843899a", "name": "", "x": 38.577945523946006, "y": -122.51486759582244, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "822f96e6-61c5-455d-8a53-a494b49c9237", "name": "p1rdm14084", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7bdf2223-6574-4b58-aadb-d8e61843899a"}}}}, {"uuid": "a906ae70-357e-4896-84e5-143cc3bd8545", "name": "", "x": 38.577881918670876, "y": -122.51474173870584, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4eb10938-4b73-406c-bed4-0bd01e0bc20d", "name": "p1rlv13641", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a906ae70-357e-4896-84e5-143cc3bd8545"}}}}, {"uuid": "143669c5-e2c1-4511-91b3-1ce3d7e385ed", "name": "", "x": 38.575528992640834, "y": -122.51891559878237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d9b16b03-1922-4aeb-8e70-d0e1387fbcab", "name": "p1rdt6518lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "143669c5-e2c1-4511-91b3-1ce3d7e385ed"}}}}, {"uuid": "9602fb20-3991-42c9-a5a7-a99c1dea8d9b", "name": "", "x": 38.5754218018766, "y": -122.51914367215898, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a8753d37-07f1-45c6-a483-43cbfb6bf107", "name": "p1rlv13647", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9602fb20-3991-42c9-a5a7-a99c1dea8d9b"}}}}, {"uuid": "5f715d2f-2c1a-4619-96c9-21d42566e2be", "name": "", "x": 38.57580840851501, "y": -122.51892297252556, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c597db56-a6af-472d-a7a2-e331175a2aae", "name": "p1rdm14085", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5f715d2f-2c1a-4619-96c9-21d42566e2be"}}}}, {"uuid": "bba05f6a-3c85-4a4a-81a0-c367140f6a1f", "name": "", "x": 38.57579807527307, "y": -122.51860159809428, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7b712121-d0c2-488a-9224-bea72928796f", "name": "p1rlv13632", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bba05f6a-3c85-4a4a-81a0-c367140f6a1f"}}}}, {"uuid": "df87e52c-507b-4c49-89b5-d67af8264dd1", "name": "", "x": 38.57533041118428, "y": -122.51883432018805, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "180c5680-acd1-4988-ac36-1f351c3f9418", "name": "p1rdm14087", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "df87e52c-507b-4c49-89b5-d67af8264dd1"}}}}, {"uuid": "4395a690-5c9a-46b3-adb7-ac922592d62f", "name": "", "x": 38.57533575960138, "y": -122.51944669646048, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "02f2e50e-d42d-47d1-9274-d840042b64d1", "name": "p1rlv20154", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4395a690-5c9a-46b3-adb7-ac922592d62f"}}}}, {"uuid": "11000b69-6f7e-48dc-859f-2cdd46f95489", "name": "", "x": 38.575287380857716, "y": -122.5193282488865, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "11a125b8-023c-4748-98a9-d74e9e0a7d23", "name": "p1rlv20161", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "11000b69-6f7e-48dc-859f-2cdd46f95489"}}}}, {"uuid": "ee4d4eec-5dfb-4f0b-b0f6-1164bf7d8847", "name": "", "x": 38.58088300114921, "y": -122.50941317390307, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "606673ea-bcd2-459a-a0af-efb8b31c600c", "name": "p1rdt6519lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ee4d4eec-5dfb-4f0b-b0f6-1164bf7d8847"}}}}, {"uuid": "d8ed7224-a9d9-4391-b993-936a9f14dbc6", "name": "", "x": 38.58045459525182, "y": -122.5092825015312, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d4d3fe62-b327-4fc6-b2aa-795c9475019a", "name": "p1rlv13636", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d8ed7224-a9d9-4391-b993-936a9f14dbc6"}}}}, {"uuid": "cc47d065-a18b-4a0d-bbb1-a923026636c1", "name": "", "x": 38.5808931056819, "y": -122.50952733350167, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3e06b069-62f8-40c8-9abc-d4cc83937e41", "name": "p1rdm14090", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc47d065-a18b-4a0d-bbb1-a923026636c1"}}}}, {"uuid": "8316b40c-759e-4de9-82e2-b7599bcc368e", "name": "", "x": 38.58036317851489, "y": -122.5089731408155, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32b75c61-4e97-4e21-a786-8aab7a2d88f8", "name": "p1rlv13678", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8316b40c-759e-4de9-82e2-b7599bcc368e"}}}}, {"uuid": "2b9af43c-355e-4977-af5d-fe2deaa37cb9", "name": "", "x": 38.580046706763056, "y": -122.51235461842337, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "13c02cd3-cff3-4988-95b9-3993b9541427", "name": "p1rdt6520lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2b9af43c-355e-4977-af5d-fe2deaa37cb9"}}}}, {"uuid": "07a6bf40-9c43-494c-a5e0-aedfb16e2e8b", "name": "", "x": 38.580041773656525, "y": -122.51253040494485, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5484eab0-53a8-471c-92ec-29c11c08e740", "name": "p1rlv13639", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "07a6bf40-9c43-494c-a5e0-aedfb16e2e8b"}}}}, {"uuid": "d1a1887e-68b9-4ba7-bb1e-9559ec608ccd", "name": "", "x": 38.5799894527048, "y": -122.51227067031124, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "607d3b54-2cea-476b-afe2-ea40c6c02ddc", "name": "p1rlv13669", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1a1887e-68b9-4ba7-bb1e-9559ec608ccd"}}}}, {"uuid": "0a2e9171-72f9-4d27-851c-45eabbd30ece", "name": "", "x": 38.57993605226405, "y": -122.51243176231385, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "db3abe20-2ffb-4bf8-b425-5613701bd3f2", "name": "p1rdm14092", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a2e9171-72f9-4d27-851c-45eabbd30ece"}}}}, {"uuid": "3e3df82e-7e0f-40fc-aef7-434dfc7f6cd8", "name": "", "x": 38.579872492217575, "y": -122.51231738436074, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2e55b944-ffad-47bf-8348-799afa4c7a1d", "name": "p1rlv13662", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e3df82e-7e0f-40fc-aef7-434dfc7f6cd8"}}}}, {"uuid": "7ede4855-ada0-4ba8-b0c6-2cef3422a414", "name": "", "x": 38.57984627020021, "y": -122.51251273462697, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c0c27b40-83a9-4938-bc12-a2ae57d5eafb", "name": "p1rdm14096", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7ede4855-ada0-4ba8-b0c6-2cef3422a414"}}}}, {"uuid": "88e1daf5-aee2-4047-8cda-6569b0fbeae0", "name": "", "x": 38.57983668465647, "y": -122.51237503029868, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "284bbc5d-bb49-404d-823e-08ec543c90b8", "name": "p1rlv13679", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "88e1daf5-aee2-4047-8cda-6569b0fbeae0"}}}}, {"uuid": "a229c490-a965-4a8a-b3d8-c55d37bf829d", "name": "", "x": 38.57981055069724, "y": -122.51248335572157, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eb3a7829-4233-4af9-9679-08bd114bc00e", "name": "p1rdm14097", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a229c490-a965-4a8a-b3d8-c55d37bf829d"}}}}, {"uuid": "9ccf5d63-0b54-4e31-90f0-2d4a9ce2a633", "name": "", "x": 38.57972969205857, "y": -122.51265129155006, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4f409299-5ac0-4f31-a217-d0aef7fbc4d2", "name": "p1rlv13705", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9ccf5d63-0b54-4e31-90f0-2d4a9ce2a633"}}}}, {"uuid": "8f222518-4a99-4211-9e54-fd4adc5c5032", "name": "", "x": 38.58009749717621, "y": -122.51224697801528, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8a990c6c-4227-4896-8ea6-e92ce5360087", "name": "p1rdm14094", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8f222518-4a99-4211-9e54-fd4adc5c5032"}}}}, {"uuid": "fa7fa1c1-aa2d-4cac-bf81-c50e1d993e77", "name": "", "x": 38.580215414329274, "y": -122.51242987363875, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9467d2d3-ad80-4bc7-aa9f-cd6e76494552", "name": "p1rlv13673", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa7fa1c1-aa2d-4cac-bf81-c50e1d993e77"}}}}, {"uuid": "9bc63553-29f4-4a9a-b99b-5521c3a3c329", "name": "", "x": 38.58029613681535, "y": -122.51233748122965, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c532e298-bdd5-416e-8ebe-a082489ffee6", "name": "p1rlv13675", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9bc63553-29f4-4a9a-b99b-5521c3a3c329"}}}}, {"uuid": "d688086c-831c-45c9-9d48-2f297d145d3d", "name": "", "x": 38.5803966658545, "y": -122.51095681258643, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d0e4e42c-8dcd-47be-bfe8-b8b1eb4a5f24", "name": "p1rdt6521lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d688086c-831c-45c9-9d48-2f297d145d3d"}}}}, {"uuid": "c69b4e5a-4201-42e7-810c-2cf0ebcc7981", "name": "", "x": 38.579486477877886, "y": -122.51051752411439, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ce53d307-fc73-487a-8f6a-3a0e0787bf79", "name": "p1rlv13670", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c69b4e5a-4201-42e7-810c-2cf0ebcc7981"}}}}, {"uuid": "690138af-24c1-49be-867e-6680bd0377bf", "name": "", "x": 38.57976641593619, "y": -122.51065339312383, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1de2ebf2-3207-4bf7-9702-4c729d99a6cf", "name": "p1rlv13694", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "690138af-24c1-49be-867e-6680bd0377bf"}}}}, {"uuid": "1a45c60d-d023-4cae-a611-68068c4a0593", "name": "", "x": 38.579567775011846, "y": -122.51056289521121, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d73963d7-acf4-48b3-8e54-6ee9f403d36f", "name": "p1rlv13695", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1a45c60d-d023-4cae-a611-68068c4a0593"}}}}, {"uuid": "caab1a9d-2a8c-4eed-959a-9039332e3168", "name": "", "x": 38.58050191288654, "y": -122.51070442912985, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c12be3d4-719e-4567-91d9-c0ff24b783f1", "name": "p1rdm14098", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "caab1a9d-2a8c-4eed-959a-9039332e3168"}}}}, {"uuid": "754ba22d-779c-4aa4-b7ce-548fb7f221dc", "name": "", "x": 38.579756732183114, "y": -122.51049272837687, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "479d1486-ed05-44fa-8fab-64035623f267", "name": "p1rlv13642", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "754ba22d-779c-4aa4-b7ce-548fb7f221dc"}}}}, {"uuid": "4d31dd12-f830-474c-9bda-1130c7c4b4f8", "name": "", "x": 38.58037890435985, "y": -122.51109366072052, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1db9a47a-f0ed-4141-b08e-f01a2ffd804f", "name": "p1rdm14100", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d31dd12-f830-474c-9bda-1130c7c4b4f8"}}}}, {"uuid": "8a46299e-61ca-4b07-a11b-4ca253e6e6cf", "name": "", "x": 38.57950522126574, "y": -122.51068960750169, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9a3c050c-cc0d-460e-af02-ce3421431474", "name": "p1rlv13682", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8a46299e-61ca-4b07-a11b-4ca253e6e6cf"}}}}, {"uuid": "c77f9530-ec0a-4054-9a05-006d849ef1ad", "name": "", "x": 38.57973678683187, "y": -122.51254142741766, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "66df2481-ae4f-4f39-aef4-7af09ce1a8fb", "name": "p1rdt6523lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c77f9530-ec0a-4054-9a05-006d849ef1ad"}}}}, {"uuid": "f39c6dd4-71cf-4d64-bcb4-da1faefa9fbc", "name": "", "x": 38.5799209440274, "y": -122.51313219164904, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "43867e2f-79ee-4cec-bed3-0cad0727118c", "name": "p1rlv13649", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f39c6dd4-71cf-4d64-bcb4-da1faefa9fbc"}}}}, {"uuid": "38154626-549f-4873-8768-aab4b840920b", "name": "", "x": 38.58054870314674, "y": -122.51023477359377, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2844042b-3f65-4a8b-8bab-56b42971e6ad", "name": "p1rdm14107", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "38154626-549f-4873-8768-aab4b840920b"}}}}, {"uuid": "28d5033a-494a-4830-857c-27385f72f97e", "name": "", "x": 38.58037752934179, "y": -122.51024741691637, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e8c0a04e-6e22-4da5-9907-7ae8097deb10", "name": "p1rlv13656", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "28d5033a-494a-4830-857c-27385f72f97e"}}}}, {"uuid": "6a791e00-55dc-4756-be50-d51a7faea780", "name": "", "x": 38.58064802372938, "y": -122.51028002263617, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "71c26ca3-0d61-46b8-a95b-710e0b760b62", "name": "p1rlv13690", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a791e00-55dc-4756-be50-d51a7faea780"}}}}, {"uuid": "1307498e-2f33-4f26-9a24-ed1f4799a1a1", "name": "", "x": 38.580549321580946, "y": -122.51038626364308, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0ec2137a-f978-4808-a023-21f13464998b", "name": "p1rdt6524lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1307498e-2f33-4f26-9a24-ed1f4799a1a1"}}}}, {"uuid": "97e975d1-b903-4ebf-b362-88304a9e927a", "name": "", "x": 38.58052253264507, "y": -122.51044160695697, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2256f06d-59e9-4822-987f-7d26f40415c0", "name": "p1rdm14109", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "97e975d1-b903-4ebf-b362-88304a9e927a"}}}}, {"uuid": "980817ce-f98e-4842-9e4e-62861e103709", "name": "", "x": 38.58056754300597, "y": -122.51042982053421, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ecf9ee9-2a3c-431b-84c8-02c7c7aaacb1", "name": "p1rlv13700", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "980817ce-f98e-4842-9e4e-62861e103709"}}}}, {"uuid": "6b9561d7-37ff-4c73-939a-cae0bfc6f012", "name": "", "x": 38.579048350921525, "y": -122.51041447766671, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f8905812-7e3b-4875-87b5-da95999c5bb0", "name": "p1rdt6527lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6b9561d7-37ff-4c73-939a-cae0bfc6f012"}}}}, {"uuid": "171206bc-5e24-403f-8776-7735ef98c781", "name": "", "x": 38.57906268295511, "y": -122.51046524008142, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ef8e6ec-86d3-429c-89b4-6c7260701e70", "name": "p1rlv13661", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "171206bc-5e24-403f-8776-7735ef98c781"}}}}, {"uuid": "29a9d0b7-9834-4fb6-9592-8530158d8ade", "name": "", "x": 38.581032746102906, "y": -122.50929836357719, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d097d9be-dd3a-4616-a873-8ab5013c4e72", "name": "p1rdt6528lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "29a9d0b7-9834-4fb6-9592-8530158d8ade"}}}}, {"uuid": "b43a9112-3dd0-4606-b9e2-b2c280cccd50", "name": "", "x": 38.580921613298514, "y": -122.50890045296518, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d6cdd514-204d-4a86-b0f3-a9bc4990a2aa", "name": "p1rlv13667", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b43a9112-3dd0-4606-b9e2-b2c280cccd50"}}}}, {"uuid": "7b51efa8-65e3-4715-b4c4-3e3fc9865126", "name": "", "x": 38.58083655075754, "y": -122.508633001311, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "850df31b-ee95-4903-93b7-6e5911e8f8a0", "name": "p1rlv13691", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7b51efa8-65e3-4715-b4c4-3e3fc9865126"}}}}, {"uuid": "7124613f-6902-4611-8bf2-0685d7cdd0ca", "name": "", "x": 38.581173273294354, "y": -122.50945964206286, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b51fe8ae-f6d7-48c7-9f84-22fc7c1c1ba9", "name": "p1rdm14115", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7124613f-6902-4611-8bf2-0685d7cdd0ca"}}}}, {"uuid": "f6ed6571-05e2-410b-a5cb-bc043ce84079", "name": "", "x": 38.58081366588884, "y": -122.50894711172428, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6e5db11f-0418-4119-9c71-26619456fd7b", "name": "p1rlv13689", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f6ed6571-05e2-410b-a5cb-bc043ce84079"}}}}, {"uuid": "f1617a39-6b0b-473b-925f-e682bab9adfc", "name": "", "x": 38.57747782265656, "y": -122.51577372256881, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e4ee2d3a-e97c-4ec4-9fa0-d7db1b3e9253", "name": "p1rdt6530lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f1617a39-6b0b-473b-925f-e682bab9adfc"}}}}, {"uuid": "3e778788-41ab-4bac-aa92-c2f1a99a4d9e", "name": "", "x": 38.57719931368139, "y": -122.51529738764073, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ec49353-14d1-4917-83bc-ca62cd94bf30", "name": "p1rlv13684", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e778788-41ab-4bac-aa92-c2f1a99a4d9e"}}}}, {"uuid": "b3fcdf02-4c33-493d-9575-5ea120899df5", "name": "", "x": 38.578752758421444, "y": -122.51042399893916, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bf4a2da0-682a-4119-b398-feaa6f5a8498", "name": "p1rdt6531lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b3fcdf02-4c33-493d-9575-5ea120899df5"}}}}, {"uuid": "dc1038de-320a-4318-bcb0-e653ac19b58f", "name": "", "x": 38.57871154896236, "y": -122.51041164293123, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c5815b75-1226-4221-9bcb-bc75ce85fa17", "name": "p1rlv13693", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dc1038de-320a-4318-bcb0-e653ac19b58f"}}}}, {"uuid": "95a9d089-ce98-467f-8ea9-9b42f507f74f", "name": "", "x": 38.58148963770846, "y": -122.5089654708908, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75c95c35-ea3f-4958-9512-606f78de92b5", "name": "p1rdm14120", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "95a9d089-ce98-467f-8ea9-9b42f507f74f"}}}}, {"uuid": "d03f9226-6e80-4991-b4fc-56e75e294b1f", "name": "", "x": 38.581272297668534, "y": -122.50871436904568, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e60fc98a-9c1d-4975-a9b9-e37271b4ac81", "name": "p1rlv13706", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d03f9226-6e80-4991-b4fc-56e75e294b1f"}}}}, {"uuid": "3c14900e-d03a-4b45-805a-10573b24aa91", "name": "", "x": 38.58157778587544, "y": -122.50884357066717, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c0c3e71a-52a1-49b9-a899-c13d639ac0a6", "name": "p1rdt6532lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3c14900e-d03a-4b45-805a-10573b24aa91"}}}}, {"uuid": "9540f591-cdc2-440a-94fd-1e5f0e14566d", "name": "", "x": 38.581615271240324, "y": -122.50883832397932, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7194199d-e430-4b76-ae77-4c7f51477eed", "name": "p1rdm14121", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9540f591-cdc2-440a-94fd-1e5f0e14566d"}}}}, {"uuid": "fcad0d46-75ae-46e8-b3c1-38c221ef9313", "name": "", "x": 38.5814179357273, "y": -122.50838439741678, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6e396aca-4116-40a0-8f17-bcd41f709ea5", "name": "p1rlv19151", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fcad0d46-75ae-46e8-b3c1-38c221ef9313"}}}}, {"uuid": "e22ae8fc-869d-4fcc-a72c-f32024a9b73d", "name": "", "x": 38.58107483274763, "y": -122.50959807912284, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "10f0e9fa-75b8-4eaa-a2ad-b6a3fb4ae859", "name": "p1rdt6535lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e22ae8fc-869d-4fcc-a72c-f32024a9b73d"}}}}, {"uuid": "0bddd491-bc72-4bbc-94d6-54da98b4518e", "name": "", "x": 38.58061410818166, "y": -122.50863848671041, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d2bfaa34-267c-4dfd-8b6d-4ab444ac4048", "name": "p1rlv13711", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0bddd491-bc72-4bbc-94d6-54da98b4518e"}}}}, {"uuid": "88973f79-5169-4a1b-921d-7cd7c4ba37ab", "name": "", "x": 38.58093200049442, "y": -122.50908714544045, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b93e7299-60a4-49d6-9d34-885860588861", "name": "p1rdt6536lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "88973f79-5169-4a1b-921d-7cd7c4ba37ab"}}}}, {"uuid": "cd358d57-6ede-4102-b78b-91c55b2a32d8", "name": "", "x": 38.58096835695191, "y": -122.50930196751384, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ee766a99-bb6f-4d5c-8513-9d462103f6fc", "name": "p1rlv13713", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cd358d57-6ede-4102-b78b-91c55b2a32d8"}}}}, {"uuid": "3c0b623a-bb42-42e7-96ad-2d9e0d3d3aed", "name": "", "x": 38.58099515130269, "y": -122.50924438048082, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a0f1846b-2515-48ef-9241-0276932f8e75", "name": "p1rlv13723", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3c0b623a-bb42-42e7-96ad-2d9e0d3d3aed"}}}}, {"uuid": "19e3403c-a263-4796-b98b-3831b386ca8d", "name": "", "x": 38.58098269315429, "y": -122.5094004338482, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "57ac4a24-2ddb-46c2-873d-c0b4f3e0600a", "name": "p1rdm14127", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "19e3403c-a263-4796-b98b-3831b386ca8d"}}}}, {"uuid": "d78ff223-7105-40b8-bf1b-61b854c6f63a", "name": "", "x": 38.581152353955275, "y": -122.50952282376217, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cd0effe0-d186-41a8-8197-24144fbc6218", "name": "p1rlv20478", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d78ff223-7105-40b8-bf1b-61b854c6f63a"}}}}, {"uuid": "14987673-7f92-410c-ab47-2773ed46e137", "name": "", "x": 38.575043333110195, "y": -122.51764982578192, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b34f50ff-9a1f-439e-81a8-dfcee658926b", "name": "p1rdt6539lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "14987673-7f92-410c-ab47-2773ed46e137"}}}}, {"uuid": "1276727e-e436-4f80-afa1-9972acfe3f6f", "name": "", "x": 38.57528171570155, "y": -122.51795068214895, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "36019623-eb62-412c-a591-41494980c9b7", "name": "p1rlv13727", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1276727e-e436-4f80-afa1-9972acfe3f6f"}}}}, {"uuid": "016059b9-2ab8-4187-9495-83fc87cb1e18", "name": "", "x": 38.57506491492146, "y": -122.51782585098714, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "006c2753-37b3-4b59-82a6-8ce95f316e26", "name": "p1rlv20450", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "016059b9-2ab8-4187-9495-83fc87cb1e18"}}}}, {"uuid": "51262455-014d-42fc-a2c6-b55e1fecf6c2", "name": "", "x": 38.660324342235185, "y": -122.44998273762167, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "36ab64e0-65cb-4515-9c06-4762a398672a", "name": "p1rdm14185", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "51262455-014d-42fc-a2c6-b55e1fecf6c2"}}}}, {"uuid": "b6bdd6fb-bd85-419a-818b-875257aff1db", "name": "", "x": 38.6601489758078, "y": -122.44970425964786, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "01a18948-75cf-4caf-951f-17a9c8d1f6bc", "name": "p1rlv13784", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b6bdd6fb-bd85-419a-818b-875257aff1db"}}}}, {"uuid": "9f0f8df4-1f7f-44b5-9ff9-a1e84cc3bf9c", "name": "", "x": 38.660528052085354, "y": -122.4498277884296, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4a43920a-a200-40fe-b5b6-3cdba0c7e784", "name": "p1rdt6574lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9f0f8df4-1f7f-44b5-9ff9-a1e84cc3bf9c"}}}}, {"uuid": "1af54902-4345-44cc-8578-75cb2bb7fef3", "name": "", "x": 38.66069273125682, "y": -122.44975004725573, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7f2b4d47-9668-4bcc-933b-1f422f423e3e", "name": "p1rdm14186", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1af54902-4345-44cc-8578-75cb2bb7fef3"}}}}, {"uuid": "c7901057-6ff0-4903-aead-e90a06af9e66", "name": "", "x": 38.66068307092049, "y": -122.44961219759635, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ffd737b-a273-4a6c-91c6-351b5719f658", "name": "p1rlv13812", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c7901057-6ff0-4903-aead-e90a06af9e66"}}}}, {"uuid": "8b51ed47-dfcb-4c2e-ac55-4c15c9ca7323", "name": "", "x": 38.659329203857624, "y": -122.45168740029418, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "608e485b-13ce-493b-be96-ab83ad733c92", "name": "p1rdt6581lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8b51ed47-dfcb-4c2e-ac55-4c15c9ca7323"}}}}, {"uuid": "f950a428-2ee0-42b5-bca3-f9b32c5e4d26", "name": "", "x": 38.66001044613518, "y": -122.45222637580909, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "65052833-aec9-4363-a0cf-4d70fa9bb0ce", "name": "p1rlv13797", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f950a428-2ee0-42b5-bca3-f9b32c5e4d26"}}}}, {"uuid": "44852aa5-fa2c-4502-9c7e-66f3665c8c8e", "name": "", "x": 38.65980253637742, "y": -122.45209003761849, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0aef2ef8-706c-4316-be01-0707ddf0ac7c", "name": "p1rlv13811", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "44852aa5-fa2c-4502-9c7e-66f3665c8c8e"}}}}, {"uuid": "405d3e33-0803-4bab-bab6-03ae336215f7", "name": "", "x": 38.659439276645934, "y": -122.45149514678252, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b8b7c677-d0bf-47d0-8a2a-78417faa49b9", "name": "p1rdm14205", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "405d3e33-0803-4bab-bab6-03ae336215f7"}}}}, {"uuid": "d0122f2a-41cc-4246-90f8-a04abd00afa7", "name": "", "x": 38.660111562159514, "y": -122.45204568307697, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dc5fcb56-435a-4a0d-b442-7489a98ad1cd", "name": "p1rlv13792", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d0122f2a-41cc-4246-90f8-a04abd00afa7"}}}}, {"uuid": "7d3f6c6b-b89e-4239-8ced-0de9f6cea967", "name": "", "x": 38.65993673921714, "y": -122.45188213185789, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c9725b6c-5bac-456a-bb6a-ce16a5e6b1a5", "name": "p1rlv13794", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7d3f6c6b-b89e-4239-8ced-0de9f6cea967"}}}}, {"uuid": "5807dfff-f120-476d-b028-21c8ea93379e", "name": "", "x": 38.66019931022639, "y": -122.45214448227058, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "83d60921-a1f2-4b9c-9709-d2be59b82db5", "name": "p1rlv13805", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5807dfff-f120-476d-b028-21c8ea93379e"}}}}, {"uuid": "762a9906-8f58-46f4-8c29-6a02b47cc88d", "name": "", "x": 38.65918069105062, "y": -122.45208328210967, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "487eef02-df2d-47fe-a20b-ce1c23064495", "name": "p1rdm14210", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "762a9906-8f58-46f4-8c29-6a02b47cc88d"}}}}, {"uuid": "883511c6-7a7d-486b-8068-fcb271ee85b0", "name": "", "x": 38.65967739844402, "y": -122.45230936703297, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "604cb559-0f18-4ef7-8bcd-a07a7e7f96d7", "name": "p1rlv19691", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "883511c6-7a7d-486b-8068-fcb271ee85b0"}}}}, {"uuid": "93ef6245-d527-43bb-bc70-7d08a2b64e0e", "name": "", "x": 38.6320710830909, "y": -122.46441945032754, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e7b9897e-b820-424c-adf8-7416de585357", "name": "p1rdt6847lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "93ef6245-d527-43bb-bc70-7d08a2b64e0e"}}}}, {"uuid": "7ee9b2d7-249f-4fa4-85bc-5e321dccdcdf", "name": "", "x": 38.632085435147204, "y": -122.46447024061165, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "06135bd7-6a77-4f04-a439-4ce8c245447d", "name": "p1rlv14434", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7ee9b2d7-249f-4fa4-85bc-5e321dccdcdf"}}}}, {"uuid": "d54e3cca-aebe-44b5-9000-f52ec82f8845", "name": "", "x": 38.62923340048788, "y": -122.45439823840434, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "94c9fa37-fc5c-4243-b0ca-f70840febaee", "name": "p1rdt6848lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d54e3cca-aebe-44b5-9000-f52ec82f8845"}}}}, {"uuid": "ead318c5-17a0-4d28-9e0b-0029efe1f9ba", "name": "", "x": 38.62920980622029, "y": -122.45452876435519, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d07f5065-df41-484d-8e8a-80b2ff4e0e9b", "name": "p1rlv14435", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ead318c5-17a0-4d28-9e0b-0029efe1f9ba"}}}}, {"uuid": "ef518207-8f21-4771-84fd-ac07da8214a1", "name": "", "x": 38.62930775436262, "y": -122.45427527251405, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ad66e41a-88ab-443e-b10e-9e7b5b899119", "name": "p1rlv14436", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef518207-8f21-4771-84fd-ac07da8214a1"}}}}, {"uuid": "1ee5b07a-7cbd-4569-b1aa-52fb1b80f325", "name": "", "x": 38.648478696952125, "y": -122.39365801344734, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "09a476ff-48a0-4d27-9cf0-c007e2e98acb", "name": "p1rdt6995lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1ee5b07a-7cbd-4569-b1aa-52fb1b80f325"}}}}, {"uuid": "c4dd9eca-e51f-46cd-9b27-abc8d242acdf", "name": "", "x": 38.6484526903026, "y": -122.39361541442939, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c9efa4c9-9832-4aa8-bf44-be0fe1e80cd5", "name": "p1rlv14828", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c4dd9eca-e51f-46cd-9b27-abc8d242acdf"}}}}, {"uuid": "a6befc82-8adc-4a0d-a14e-865e43d77c0a", "name": "", "x": 38.64916844328969, "y": -122.39459452477139, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "536d7c56-85a6-4167-b4f6-2f39936cd662", "name": "p1rdt7015lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a6befc82-8adc-4a0d-a14e-865e43d77c0a"}}}}, {"uuid": "d69748df-ccc3-48ce-9654-18f617d9fb69", "name": "", "x": 38.64918282560407, "y": -122.39464531276182, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d73b0321-e181-4ecd-b431-9aa6985d56d0", "name": "p1rlv14908", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d69748df-ccc3-48ce-9654-18f617d9fb69"}}}}, {"uuid": "8fcb6705-048d-4877-a0bc-e606511d2295", "name": "", "x": 38.56296537249011, "y": -122.50762584426352, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1a371c8b-1993-432c-b2c6-21b18bec27da", "name": "p1rdt7036lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8fcb6705-048d-4877-a0bc-e606511d2295"}}}}, {"uuid": "9037b898-87b5-4754-92ad-23b3c26383e7", "name": "", "x": 38.56302965746093, "y": -122.50745371127641, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3c39b0c-9c92-4934-876f-ee5f542f95cc", "name": "p1rlv14952", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9037b898-87b5-4754-92ad-23b3c26383e7"}}}}, {"uuid": "125c32e8-53ea-4b99-a462-4873a5fbd551", "name": "", "x": 38.562911104383154, "y": -122.50779489358709, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "260ea1f0-7235-47fc-a576-3d647618290e", "name": "p1rdm15468", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "125c32e8-53ea-4b99-a462-4873a5fbd551"}}}}, {"uuid": "dfd993e3-9f3d-4b0c-bd6a-abd0bcfed918", "name": "", "x": 38.56269409956021, "y": -122.50762420325977, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "19231152-1fd1-4e07-a5d9-603c765b2cae", "name": "p1rlv15008", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dfd993e3-9f3d-4b0c-bd6a-abd0bcfed918"}}}}, {"uuid": "adac6dc8-8be6-48fb-949a-6b94d12f7d4b", "name": "", "x": 38.56256229551184, "y": -122.50269706817427, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "046f6c53-8d9c-43a1-88ce-169ade9e9557", "name": "p1rdt7038lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "adac6dc8-8be6-48fb-949a-6b94d12f7d4b"}}}}, {"uuid": "8ca7ccc6-e0d8-4b03-856f-60ac9d14b366", "name": "", "x": 38.562607012632625, "y": -122.50261641391278, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a9e128f5-eb18-44df-8ec4-35bd049ef630", "name": "p1rlv14954", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8ca7ccc6-e0d8-4b03-856f-60ac9d14b366"}}}}, {"uuid": "e911b985-e79e-4f2c-93b3-ef325ec3ea1e", "name": "", "x": 38.56228530015727, "y": -122.50538482056976, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cd6a9808-9889-4f16-825d-c9763357c293", "name": "p1rdt7046lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e911b985-e79e-4f2c-93b3-ef325ec3ea1e"}}}}, {"uuid": "859e95c6-17e7-4a0d-9a9d-6892808b6de9", "name": "", "x": 38.56236063103573, "y": -122.50548009684834, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "884ff47e-8e20-4ae8-97bd-287d0ca9dc1b", "name": "p1rlv14974", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "859e95c6-17e7-4a0d-9a9d-6892808b6de9"}}}}, {"uuid": "971c2a17-55d8-4d9f-9371-a6f61aafe5a7", "name": "", "x": 38.558417547967906, "y": -122.507932804306, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf93e681-3ab6-4929-95f1-1da6d5dd28fa", "name": "p1rdt7054lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "971c2a17-55d8-4d9f-9371-a6f61aafe5a7"}}}}, {"uuid": "08d23886-0c5d-44c8-b2ad-7ea381317beb", "name": "", "x": 38.55834318385272, "y": -122.50806707079614, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f4f8b1bc-83c3-4819-9d98-9491df98d494", "name": "p1rlv14992", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "08d23886-0c5d-44c8-b2ad-7ea381317beb"}}}}, {"uuid": "2b6a7bde-a0c4-449f-8fe4-d8400882bf90", "name": "", "x": 38.55812685464717, "y": -122.50805706795369, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a914ec3a-4883-42a7-b25d-133a1410b8d9", "name": "p1rlv15056", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2b6a7bde-a0c4-449f-8fe4-d8400882bf90"}}}}, {"uuid": "5e15ee0b-3693-41ac-8cb0-055c517b69d7", "name": "", "x": 38.558469106593094, "y": -122.50800882572935, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25a6c92d-ea7f-4ede-af16-713ceedfc7b0", "name": "p1rdm15533", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5e15ee0b-3693-41ac-8cb0-055c517b69d7"}}}}, {"uuid": "356f834c-0b74-448a-bb21-123afc00d12d", "name": "", "x": 38.558289451182375, "y": -122.50814777833953, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2182c9fd-fd3d-4cb1-b525-192480823e2f", "name": "p1rlv15046", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "356f834c-0b74-448a-bb21-123afc00d12d"}}}}, {"uuid": "1aaf2a4d-ff03-454e-a713-9582309fa5ce", "name": "", "x": 38.559657411750145, "y": -122.50277093263843, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bc33ade7-4471-40b8-8e9b-1846e0ad60e8", "name": "p1rdt7061lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1aaf2a4d-ff03-454e-a713-9582309fa5ce"}}}}, {"uuid": "637627d3-e56a-4bc8-9ff8-1a6c5760087b", "name": "", "x": 38.55937583329394, "y": -122.50291811146595, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cc29de5b-3a3f-40c0-bde4-9a57f5f62b5c", "name": "p1rlv15007", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "637627d3-e56a-4bc8-9ff8-1a6c5760087b"}}}}, {"uuid": "2c405f7c-6e09-4705-a315-e45355677bb1", "name": "", "x": 38.563364746370645, "y": -122.50424505524006, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f4445ca5-2fed-4352-ab78-66e072a4f482", "name": "p1rdm15583", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2c405f7c-6e09-4705-a315-e45355677bb1"}}}}, {"uuid": "55ebc70c-c0d4-4a17-bcc7-8a77aee0e74b", "name": "", "x": 38.56324735128747, "y": -122.50418847116366, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "07e3b847-cc9a-4f84-bc00-cb4396b6dea0", "name": "p1rlv15027", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "55ebc70c-c0d4-4a17-bcc7-8a77aee0e74b"}}}}, {"uuid": "c5817b8f-ea88-454f-88ee-92b03f9a1ddf", "name": "", "x": 38.56307400876931, "y": -122.50435786467884, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1ff878e1-3143-4f8e-aa92-74d0a9046417", "name": "p1rdt7067lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c5817b8f-ea88-454f-88ee-92b03f9a1ddf"}}}}, {"uuid": "a34ca3d2-08f9-4046-8516-8323c5dbc0bb", "name": "", "x": 38.562913772741126, "y": -122.50415632890832, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5ad4c131-0be7-46e5-8a32-5ff92552dfe6", "name": "p1rdm15584", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a34ca3d2-08f9-4046-8516-8323c5dbc0bb"}}}}, {"uuid": "e8c80a4b-9086-4dc3-828c-6661b91adb34", "name": "", "x": 38.563057133200985, "y": -122.50396021637685, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "80a74c6f-c9ec-4742-8fce-ad73c0a6c459", "name": "p1rlv15197", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e8c80a4b-9086-4dc3-828c-6661b91adb34"}}}}, {"uuid": "63c74f01-b8e6-49bc-8ad2-88e28191cae0", "name": "", "x": 38.559099227598956, "y": -122.50637076262426, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9a1566f1-7f0d-41d7-adad-425c9a344eb0", "name": "p1rdt7069lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "63c74f01-b8e6-49bc-8ad2-88e28191cae0"}}}}, {"uuid": "12d42c56-9b80-4486-a359-8e37f81f809d", "name": "", "x": 38.558729158203484, "y": -122.50556236696406, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "baccbdab-efc0-487d-b00d-38d3d4be57b4", "name": "p1rlv15045", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "12d42c56-9b80-4486-a359-8e37f81f809d"}}}}, {"uuid": "56999ec8-df70-47e8-a22e-684768da3d2c", "name": "", "x": 38.56237327512186, "y": -122.49906112727943, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "844bdc22-2e32-43ee-8e0b-26f3f4c107b8", "name": "p1rdt7070lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "56999ec8-df70-47e8-a22e-684768da3d2c"}}}}, {"uuid": "e3bc0fa3-6811-498e-a16c-8320d0a293f7", "name": "", "x": 38.5623473065519, "y": -122.49901854030558, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "366c9c98-59f1-46d5-b39c-4046703e5e4b", "name": "p1rlv15064", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e3bc0fa3-6811-498e-a16c-8320d0a293f7"}}}}, {"uuid": "a83cc9c4-4b11-4010-aa19-b53e73508459", "name": "", "x": 38.56125382119533, "y": -122.50733957591181, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0e0577c2-8275-4303-ad11-2c4f56df3f5c", "name": "p1rdt7075lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a83cc9c4-4b11-4010-aa19-b53e73508459"}}}}, {"uuid": "9a93678c-2745-43ef-87e0-0b312f04dcc6", "name": "", "x": 38.56131680649824, "y": -122.50731619031008, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a56b9ad8-c53b-4652-bf94-a7a7dfb8b306", "name": "p1rlv15082", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9a93678c-2745-43ef-87e0-0b312f04dcc6"}}}}, {"uuid": "5c7c788f-e292-4ed5-b8b6-2d92179a1549", "name": "", "x": 38.561391603460336, "y": -122.50795843776592, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d86bd7f-7759-4d74-9c74-d58010498f92", "name": "p1rdt7080lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5c7c788f-e292-4ed5-b8b6-2d92179a1549"}}}}, {"uuid": "67d11589-d890-4924-88d4-c67f869a6f93", "name": "", "x": 38.561343164924004, "y": -122.50782854332392, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "161d4e7b-30f2-447c-a369-1bfa3ba2cd70", "name": "p1rlv15109", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "67d11589-d890-4924-88d4-c67f869a6f93"}}}}, {"uuid": "95c151ef-ad3e-4f24-a147-4c639e3a18d2", "name": "", "x": 38.56161341947106, "y": -122.5078037444857, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bb6d8f13-f04e-4b80-a8dc-e16af1dc860e", "name": "p1rlv15125", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "95c151ef-ad3e-4f24-a147-4c639e3a18d2"}}}}, {"uuid": "4b3c05ad-cedd-477b-93ed-febea5d5232f", "name": "", "x": 38.559858339047835, "y": -122.50687058401597, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d0c96fe-78c2-4303-ac5c-bbe440f19666", "name": "p1rdt7087lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4b3c05ad-cedd-477b-93ed-febea5d5232f"}}}}, {"uuid": "db357bf8-bd4f-49eb-b3b1-04933eed13f3", "name": "", "x": 38.56006676468359, "y": -122.5064714121144, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bdee6d84-9253-4fba-b713-3e41d706e999", "name": "p1rlv15163", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "db357bf8-bd4f-49eb-b3b1-04933eed13f3"}}}}, {"uuid": "7c2faef8-a10d-4e28-bc4d-8542fee740d0", "name": "", "x": 38.55723982473556, "y": -122.5059256790796, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0f1652e8-6cf7-43d4-8474-e61a74873675", "name": "p1rdt7088lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7c2faef8-a10d-4e28-bc4d-8542fee740d0"}}}}, {"uuid": "5715e666-b8a9-484f-ba5f-8126a94010c7", "name": "", "x": 38.55722600645399, "y": -122.50597665691777, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2d2f8fcb-c279-49d5-88be-39e6a1d1990b", "name": "p1rlv15170", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5715e666-b8a9-484f-ba5f-8126a94010c7"}}}}, {"uuid": "0b91e779-c081-46eb-ba57-0400b5966cb1", "name": "", "x": 38.55763186186392, "y": -122.50515401038457, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "73cfcce9-a925-4f29-9cde-6dd6f50735e1", "name": "p1rdt7089lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0b91e779-c081-46eb-ba57-0400b5966cb1"}}}}, {"uuid": "7645a840-49f1-4f3d-bf88-0d557ff10242", "name": "", "x": 38.5576058954936, "y": -122.50511142397353, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dc7cd505-823c-49bb-9e49-3681267dbef0", "name": "p1rlv15171", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7645a840-49f1-4f3d-bf88-0d557ff10242"}}}}, {"uuid": "1846601f-ea73-4a6d-b41f-f06723617295", "name": "", "x": 38.55819291339373, "y": -122.50729514639205, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5d6a4c80-d261-4350-8224-8fe5191459c7", "name": "p1rdt7090lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1846601f-ea73-4a6d-b41f-f06723617295"}}}}, {"uuid": "5f1f5eaa-fca2-4063-8623-d2c87240ac98", "name": "", "x": 38.558186799297566, "y": -122.50731063399988, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e218b01d-f713-4baf-9688-7e77ea413c8c", "name": "p1rlv15180", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5f1f5eaa-fca2-4063-8623-d2c87240ac98"}}}}, {"uuid": "d41eed58-eb05-4eb6-91b8-26ead7b42739", "name": "", "x": 38.643254518897194, "y": -122.45483995487372, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6718b871-3967-4c29-83e5-441799c7fb92", "name": "p1rdt7201lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d41eed58-eb05-4eb6-91b8-26ead7b42739"}}}}, {"uuid": "b9bae9e3-62cb-4c3b-a8b7-2fdb6158be87", "name": "", "x": 38.64314352984028, "y": -122.45483682254313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fd21ae8b-7841-43b4-871f-316c4b8b4cd2", "name": "p1rlv15394", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b9bae9e3-62cb-4c3b-a8b7-2fdb6158be87"}}}}, {"uuid": "8c6660ec-b375-4cc2-8f0d-b4269bbad1e5", "name": "", "x": 38.64359496143701, "y": -122.45501725670924, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5ec1f313-f341-498c-b1c2-6669b1cbc629", "name": "p1rlv15399", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8c6660ec-b375-4cc2-8f0d-b4269bbad1e5"}}}}, {"uuid": "862f0625-04be-4c1c-9407-0449f1b4e76d", "name": "", "x": 38.643369459814934, "y": -122.45497300119509, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8bc46399-0276-4ae7-aa8b-4cdd3d3555e8", "name": "p1rlv15419", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "862f0625-04be-4c1c-9407-0449f1b4e76d"}}}}, {"uuid": "6d0c0017-941d-496d-a360-3f767288ac7d", "name": "", "x": 38.643190246717545, "y": -122.45519268460242, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "335df4da-50d2-4fbe-a271-ac04257d35c7", "name": "p1rlv15478", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6d0c0017-941d-496d-a360-3f767288ac7d"}}}}, {"uuid": "f9f10379-c1aa-4451-908d-38eecfa2b445", "name": "", "x": 38.6429090279938, "y": -122.45418759719459, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "37ccfa64-1373-49b2-85f6-279abea3c945", "name": "p1rlv15523", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f9f10379-c1aa-4451-908d-38eecfa2b445"}}}}, {"uuid": "f75bd794-6d16-46ee-99bd-adaf4993874e", "name": "", "x": 38.64844611776415, "y": -122.46453889053006, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5d5e45d6-867a-4442-8258-2c04891dbc4b", "name": "p1rdt7220lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f75bd794-6d16-46ee-99bd-adaf4993874e"}}}}, {"uuid": "16ccf6c7-32c1-4714-b004-edbd0fcf2460", "name": "", "x": 38.64842013673824, "y": -122.46449626559803, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f9ca373a-b1c3-464d-bbe3-c05b728beb30", "name": "p1rlv15418", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "16ccf6c7-32c1-4714-b004-edbd0fcf2460"}}}}, {"uuid": "6226913c-7d7d-477d-95e9-54bb8abd2648", "name": "", "x": 38.64544505846416, "y": -122.42121162161781, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d6a6156f-e72a-41f0-a307-e6030de24fde", "name": "p1rdt7224lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6226913c-7d7d-477d-95e9-54bb8abd2648"}}}}, {"uuid": "27cb7911-2e9b-464c-93c0-ac632f6ff630", "name": "", "x": 38.64521777279914, "y": -122.42138184387917, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "921f8f54-ff83-4d2f-8bf4-ee80bab64ce8", "name": "p1rlv15487", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "27cb7911-2e9b-464c-93c0-ac632f6ff630"}}}}, {"uuid": "69b27ea4-60b0-4eda-81a3-4486c128089b", "name": "", "x": 38.64535123894055, "y": -122.42103603545684, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "79c5341b-3cd2-41a3-8bbf-e50857b00dae", "name": "p1rdm15891", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "69b27ea4-60b0-4eda-81a3-4486c128089b"}}}}, {"uuid": "09527da2-781f-41bf-b313-d35ece88a326", "name": "", "x": 38.64513570345144, "y": -122.42118715458822, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "26009a7e-9bfc-4967-af28-4d8937539eb1", "name": "p1rlv15423", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "09527da2-781f-41bf-b313-d35ece88a326"}}}}, {"uuid": "bb839b26-b6d1-4449-a1b9-452e490d2a89", "name": "", "x": 38.64529779575312, "y": -122.42116286827518, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "34e0ffc2-da17-441b-bd4d-26d5a1104712", "name": "p1rlv15474", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bb839b26-b6d1-4449-a1b9-452e490d2a89"}}}}, {"uuid": "a328fc38-9751-4e00-9895-2603399f0135", "name": "", "x": 38.648428944357136, "y": -122.46102923499245, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2087cee5-9f6e-4400-8ca8-bbb120cd4dae", "name": "p1rdt7248lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a328fc38-9751-4e00-9895-2603399f0135"}}}}, {"uuid": "750db3fa-bb1a-4d04-b712-ff839caf5bfb", "name": "", "x": 38.64843531677844, "y": -122.46107118044478, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "544be417-0db6-45a7-8314-ec40944781fa", "name": "p1rlv15466", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "750db3fa-bb1a-4d04-b712-ff839caf5bfb"}}}}, {"uuid": "862f5d4c-08c7-48f1-a229-70ced1db006d", "name": "", "x": 38.648497708978724, "y": -122.4609213210892, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3c4e3eac-0b1a-4feb-b39f-079c6d2c1d82", "name": "p1rlv15483", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "862f5d4c-08c7-48f1-a229-70ced1db006d"}}}}, {"uuid": "32bfc63e-f0fa-4281-8265-4295041aa664", "name": "", "x": 38.64803011681224, "y": -122.46114316554923, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6579cc93-2b08-4010-816d-3bef509000cd", "name": "p1rlv15488", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "32bfc63e-f0fa-4281-8265-4295041aa664"}}}}, {"uuid": "6a9646be-d91a-42e6-b44c-c57056f16ac4", "name": "", "x": 38.64867815080695, "y": -122.46096593584461, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b09822b3-a220-48ff-ad4f-62fca602f8b6", "name": "p1rlv15542", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a9646be-d91a-42e6-b44c-c57056f16ac4"}}}}, {"uuid": "009068dc-1050-4ede-85b3-38c88606ebaa", "name": "", "x": 38.64806971694897, "y": -122.4591176468453, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b4f7df4-5453-459d-8599-48fd5f29a9c6", "name": "p1rdt7253lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "009068dc-1050-4ede-85b3-38c88606ebaa"}}}}, {"uuid": "4f4045d5-a424-4828-8712-a5e2d27af07c", "name": "", "x": 38.6480437339618, "y": -122.45907502411583, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6749066f-4739-41ec-8369-8da49dd9e1c8", "name": "p1rlv15484", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4f4045d5-a424-4828-8712-a5e2d27af07c"}}}}, {"uuid": "ce488c5f-6b15-495e-a1dc-3e08aea6376a", "name": "", "x": 38.650849807011845, "y": -122.4260111114199, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1130272e-b98e-496f-aeb9-c094cf9cd824", "name": "p1rdt7268lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ce488c5f-6b15-495e-a1dc-3e08aea6376a"}}}}, {"uuid": "6a086fd3-e4a3-4194-82d1-3d55ac26d4a6", "name": "", "x": 38.650823812052785, "y": -122.42596849916298, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6eec860d-08cf-4690-93e6-d909429d363d", "name": "p1rlv15525", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a086fd3-e4a3-4194-82d1-3d55ac26d4a6"}}}}, {"uuid": "654a9de7-dcb0-4746-8171-280e65546dae", "name": "", "x": 38.56642393843708, "y": -122.500066081999, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d304e5e0-2cc1-4167-9fad-6fc72228d828", "name": "p1rdt7298lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "654a9de7-dcb0-4746-8171-280e65546dae"}}}}, {"uuid": "6a642350-2238-4a5c-825f-8e833548e191", "name": "", "x": 38.56639797023211, "y": -122.50002349228465, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "688da57a-6f10-4ef8-8763-202a88c3a495", "name": "p1rlv15603", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a642350-2238-4a5c-825f-8e833548e191"}}}}, {"uuid": "81704916-b78c-4299-8fc1-4958e3705545", "name": "", "x": 38.586910904171326, "y": -122.52012069769289, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "43df4c14-a198-4d51-87f4-80000198cd47", "name": "p1rdt7301lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "81704916-b78c-4299-8fc1-4958e3705545"}}}}, {"uuid": "9fcd0830-ea92-460e-88c4-2f39c88f4ed7", "name": "", "x": 38.58688494322849, "y": -122.52007808865979, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c32ce070-e690-4fc1-92ac-f857691de578", "name": "p1rlv15606", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9fcd0830-ea92-460e-88c4-2f39c88f4ed7"}}}}, {"uuid": "a00d66f5-e5d7-4a85-b1e2-41d52b447303", "name": "", "x": 38.56306853879527, "y": -122.5102770561152, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3e2a141f-436a-45c0-9c15-179301a439c8", "name": "p1rdt7302lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a00d66f5-e5d7-4a85-b1e2-41d52b447303"}}}}, {"uuid": "aa80928f-e27e-42d3-ab52-19e97aa61d61", "name": "", "x": 38.56308491307865, "y": -122.51055992850522, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32291502-d7be-4b45-8af7-cb217448e73f", "name": "p1rlv15607", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aa80928f-e27e-42d3-ab52-19e97aa61d61"}}}}, {"uuid": "cd52fc3f-b014-47cf-820c-b191189ba802", "name": "", "x": 38.563191661348114, "y": -122.51022633928095, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2715a637-d6f0-4e7b-b43e-20836bf4e614", "name": "p1rlv15638", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cd52fc3f-b014-47cf-820c-b191189ba802"}}}}, {"uuid": "62d95444-7296-4d3a-8cb0-3fa5dd858b1b", "name": "", "x": 38.56290700610434, "y": -122.51179679741092, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0926064a-1c87-450a-b282-23708de8aec4", "name": "p1rdt7306lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "62d95444-7296-4d3a-8cb0-3fa5dd858b1b"}}}}, {"uuid": "bf198d6d-a6e0-4737-a4e7-8a2939338d8d", "name": "", "x": 38.56368313784799, "y": -122.511382300603, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5ab2d6dc-f5bb-4320-86f3-bf08bb7cf93f", "name": "p1rlv15614", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bf198d6d-a6e0-4737-a4e7-8a2939338d8d"}}}}, {"uuid": "5fea1be8-832e-410d-af35-560129d549bc", "name": "", "x": 38.57387166576081, "y": -122.5068092396372, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6ce9dd2c-9e17-46b7-a6f4-e85077664432", "name": "p1rdt7307lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5fea1be8-832e-410d-af35-560129d549bc"}}}}, {"uuid": "e984cc18-d43d-4279-98ad-7a297ad808c9", "name": "", "x": 38.573802276520816, "y": -122.50677924408086, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6106bbe7-7a47-4c50-8b2a-d46d7432bccf", "name": "p1rlv15617", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e984cc18-d43d-4279-98ad-7a297ad808c9"}}}}, {"uuid": "60d115bb-a2f5-47fd-ad21-f774776aafdc", "name": "", "x": 38.573945931269776, "y": -122.50665198381543, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0bb184ad-cb26-4317-8c40-f2c8a9f80dab", "name": "p1rlv19146", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "60d115bb-a2f5-47fd-ad21-f774776aafdc"}}}}, {"uuid": "6243e000-7c2a-4199-aba2-ca01fe1b1dd7", "name": "", "x": 38.57392039558398, "y": -122.50700803276428, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "546433b3-d70e-49ed-9037-ec88adda79b9", "name": "p1rlv19147", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6243e000-7c2a-4199-aba2-ca01fe1b1dd7"}}}}, {"uuid": "1df6c2be-0b95-47ed-8ccf-650263d8acdb", "name": "", "x": 38.563303651285544, "y": -122.5126284769322, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e2d6046b-9ece-4295-a180-41bf2ce47ce6", "name": "p1rdt7311lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1df6c2be-0b95-47ed-8ccf-650263d8acdb"}}}}, {"uuid": "daba764b-a0fc-4c47-b9d1-f41023553bb6", "name": "", "x": 38.56384855592281, "y": -122.51215022095688, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1151b559-3ae0-4863-9363-9b395bbfc403", "name": "p1rlv15622", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "daba764b-a0fc-4c47-b9d1-f41023553bb6"}}}}, {"uuid": "1f14723b-86dc-4a46-a672-3ed1ff4b6072", "name": "", "x": 38.56815134225955, "y": -122.50546068410047, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "97844fdb-b016-4ca3-8777-b0553ead9297", "name": "p1rdt7314lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1f14723b-86dc-4a46-a672-3ed1ff4b6072"}}}}, {"uuid": "ea07bd82-2337-41b7-ac6c-4158f09b55a2", "name": "", "x": 38.56817687324023, "y": -122.50541766691859, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ec0bca53-a58b-4004-8dba-8defca9db4c7", "name": "p1rlv15629", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea07bd82-2337-41b7-ac6c-4158f09b55a2"}}}}, {"uuid": "502ec234-aaf7-4749-8910-9336c0c13d45", "name": "", "x": 38.56855471658057, "y": -122.50523980787194, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "22b1ecce-d5df-4f42-abb2-9f4c3d3a28c5", "name": "p1rdt7318lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "502ec234-aaf7-4749-8910-9336c0c13d45"}}}}, {"uuid": "7ae0df86-6d12-44d0-9fd4-967a2abacbfa", "name": "", "x": 38.568569050828, "y": -122.50529056187261, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a5af6dae-d20f-4a31-9544-b9455cd639bd", "name": "p1rlv15634", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7ae0df86-6d12-44d0-9fd4-967a2abacbfa"}}}}, {"uuid": "c125e674-85b7-4f60-93b0-24e4722e6cc3", "name": "", "x": 38.60115277629168, "y": -122.46102699453549, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "58be5cbe-5a7c-4fa5-972d-e03100b3bb46", "name": "p1rdt7550lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c125e674-85b7-4f60-93b0-24e4722e6cc3"}}}}, {"uuid": "d96464bf-d57f-4a79-95ab-73e600c00eb4", "name": "", "x": 38.60105048076314, "y": -122.46095488399553, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5984e209-9f0e-4844-91e6-902c8329f13c", "name": "p1rlv16114", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d96464bf-d57f-4a79-95ab-73e600c00eb4"}}}}, {"uuid": "f04f0ccb-57e8-461b-80fb-4acde4ab77df", "name": "", "x": 38.60120431220644, "y": -122.46109154303083, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "807b0bef-0d34-44a9-a2a9-0c0a11f4ea8e", "name": "p1rlv16178", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f04f0ccb-57e8-461b-80fb-4acde4ab77df"}}}}, {"uuid": "6b7c2c76-7774-48ee-910e-81eb26d11585", "name": "", "x": 38.60318695205525, "y": -122.45853113684389, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1c4d7ee3-fc5d-4a17-a717-3d6b6d5a67ae", "name": "p1rdt7551lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6b7c2c76-7774-48ee-910e-81eb26d11585"}}}}, {"uuid": "6cf6c48f-0c39-4e82-aaa5-9850a4ea3d6c", "name": "", "x": 38.6034004318743, "y": -122.45853704613184, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "52d1b79d-5c6b-4b44-9998-600c6debd999", "name": "p1rlv16115", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6cf6c48f-0c39-4e82-aaa5-9850a4ea3d6c"}}}}, {"uuid": "ce389c53-ae3e-4477-bd2e-926434e7d3c2", "name": "", "x": 38.60293177722496, "y": -122.45852908328547, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6efff4f7-c67b-4cfb-a72d-30b6616825b1", "name": "p1rlv16157", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ce389c53-ae3e-4477-bd2e-926434e7d3c2"}}}}, {"uuid": "86be8abe-cfa1-408c-9fae-445d6897801f", "name": "", "x": 38.601851120199065, "y": -122.45542100224573, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1f5d6708-cef4-4aac-9fa0-c738953c788f", "name": "p1rdt7552lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "86be8abe-cfa1-408c-9fae-445d6897801f"}}}}, {"uuid": "7d645f59-ab39-476e-b903-ae66856dfb97", "name": "", "x": 38.60199783561238, "y": -122.45535495885304, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "972f8088-b67b-47d0-a86f-49179dfb1c92", "name": "p1rlv16116", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7d645f59-ab39-476e-b903-ae66856dfb97"}}}}, {"uuid": "5306fedc-377c-405e-8294-70ab141da9c9", "name": "", "x": 38.60173719494335, "y": -122.45550622371668, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "92a37082-36d4-4eca-95e4-88dbcacd6db5", "name": "p1rlv16197", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5306fedc-377c-405e-8294-70ab141da9c9"}}}}, {"uuid": "2f0e73df-0c62-40a8-a734-286365ac0370", "name": "", "x": 38.60639320900444, "y": -122.45582291610495, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e7a672b2-d127-4fb5-8cc4-8115b8ef3f60", "name": "p1rdt7553lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2f0e73df-0c62-40a8-a734-286365ac0370"}}}}, {"uuid": "9c579c2e-db54-4d6b-906e-b3e3396c2a73", "name": "", "x": 38.606405183855294, "y": -122.45547094869913, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "204899ec-81e4-4a72-bf70-69b3428a49a1", "name": "p1rlv16117", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9c579c2e-db54-4d6b-906e-b3e3396c2a73"}}}}, {"uuid": "2bf36cf3-92b0-4202-afe5-e4a82e38ea10", "name": "", "x": 38.60746648825486, "y": -122.45829224306911, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "86a6d184-d883-4e27-aee5-b89c82163284", "name": "p1rdt7554lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2bf36cf3-92b0-4202-afe5-e4a82e38ea10"}}}}, {"uuid": "2df0eb30-a882-4def-ab77-29e11f4fd85d", "name": "", "x": 38.60753796176142, "y": -122.45877011077201, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bca0b3a0-d4cb-4a4a-9b14-aa23d9e5e5fe", "name": "p1rlv16118", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2df0eb30-a882-4def-ab77-29e11f4fd85d"}}}}, {"uuid": "c4771003-2c0d-47fc-bf08-901d4c211e51", "name": "", "x": 38.60761943761314, "y": -122.45884989486198, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c840cf3f-be15-448b-8c03-8942c586b135", "name": "p1rlv16139", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c4771003-2c0d-47fc-bf08-901d4c211e51"}}}}, {"uuid": "14b6738b-41dd-4f20-ab31-7fd70218af0b", "name": "", "x": 38.60732511225313, "y": -122.45756577239354, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "68aa5cc5-f6bf-4417-8653-747c56b37b5e", "name": "p1rlv16201", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "14b6738b-41dd-4f20-ab31-7fd70218af0b"}}}}, {"uuid": "0b85b1e3-d355-43b8-8b7a-6468a77acd10", "name": "", "x": 38.60729988695483, "y": -122.45795645616205, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf413742-18c8-483d-b8f1-f125f95323da", "name": "p1rlv16209", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0b85b1e3-d355-43b8-8b7a-6468a77acd10"}}}}, {"uuid": "988e9a2d-9ed8-4c63-b121-042df9ce3188", "name": "", "x": 38.599910107670105, "y": -122.4605115694972, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0de9c581-b78b-44d6-8693-59b995e2a3bb", "name": "p1rdt7555lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "988e9a2d-9ed8-4c63-b121-042df9ce3188"}}}}, {"uuid": "53064509-7052-4af7-87fe-e13f6ad6d921", "name": "", "x": 38.60005645544839, "y": -122.46036515331646, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c0d6e608-d5bf-40d6-9efd-f3b0922e7d77", "name": "p1rlv16119", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "53064509-7052-4af7-87fe-e13f6ad6d921"}}}}, {"uuid": "7829fac3-fe6e-4708-aebe-204569ca6f84", "name": "", "x": 38.607794956621454, "y": -122.45548336703727, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0b593ec6-e1e3-48c2-b352-f7966f206aa9", "name": "p1rdt7559lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7829fac3-fe6e-4708-aebe-204569ca6f84"}}}}, {"uuid": "84d7a033-8e7b-4fb0-9cc0-c8644b232b05", "name": "", "x": 38.60770977446864, "y": -122.45501316679001, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6da4b2d0-66c7-43fb-9aab-3bbac03aa989", "name": "p1rlv16124", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "84d7a033-8e7b-4fb0-9cc0-c8644b232b05"}}}}, {"uuid": "cb0b839a-cd6f-491d-932b-83f7ff4c8736", "name": "", "x": 38.60025024332015, "y": -122.46073516079042, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "05e30abd-3c40-4dbd-9261-ca8a8abd9c56", "name": "p1rdt7561lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb0b839a-cd6f-491d-932b-83f7ff4c8736"}}}}, {"uuid": "e788a403-3ee0-4bc1-83e8-447ea9a8a20a", "name": "", "x": 38.60030209684127, "y": -122.46086860989422, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bd41f55a-4b5d-4c19-9787-801072b3b946", "name": "p1rlv16126", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e788a403-3ee0-4bc1-83e8-447ea9a8a20a"}}}}, {"uuid": "4124fd29-4733-49fc-a471-b50ad153de68", "name": "", "x": 38.60042704179853, "y": -122.46060354272663, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "102b9460-ea9a-4099-b16f-40b8fdf99ef7", "name": "p1rlv16133", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4124fd29-4733-49fc-a471-b50ad153de68"}}}}, {"uuid": "0d6f3592-9121-45e3-9cbe-84457185ba70", "name": "", "x": 38.60180967142113, "y": -122.46424249788332, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f7588b3b-f54c-483d-b354-b9908483019a", "name": "p1rdt7564lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0d6f3592-9121-45e3-9cbe-84457185ba70"}}}}, {"uuid": "8dec918d-10ab-432a-b8bb-e415a12f101b", "name": "", "x": 38.60183518685866, "y": -122.46419944605898, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "676de1a3-2dfd-4faa-a057-7739e825d136", "name": "p1rlv16135", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8dec918d-10ab-432a-b8bb-e415a12f101b"}}}}, {"uuid": "31d60c7f-e3f0-4686-8e19-b56bd4e1464a", "name": "", "x": 38.6078075576706, "y": -122.45772713266135, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f2b3b9e1-3d98-44c1-bd38-9325623a1553", "name": "p1rdt7570lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "31d60c7f-e3f0-4686-8e19-b56bd4e1464a"}}}}, {"uuid": "fa7474fe-414e-4687-8d13-9b47b7f5bf2e", "name": "", "x": 38.60779838775444, "y": -122.45777980644779, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6d21c357-1033-45e1-84a0-b82ceafe6ab8", "name": "p1rlv16146", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa7474fe-414e-4687-8d13-9b47b7f5bf2e"}}}}, {"uuid": "14c8ea02-6b8a-4683-a209-b207e62df26b", "name": "", "x": 38.60626762047214, "y": -122.45581795786703, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "69bf048e-54cd-4e41-a23e-485b0cd98fae", "name": "p1rdt7572lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "14c8ea02-6b8a-4683-a209-b207e62df26b"}}}}, {"uuid": "2814eb4a-ef43-4726-81b5-35cb10bb963a", "name": "", "x": 38.60645647275145, "y": -122.45487334223284, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b15792ca-a6bd-47e5-8c67-5c3076174848", "name": "p1rlv16149", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2814eb4a-ef43-4726-81b5-35cb10bb963a"}}}}, {"uuid": "84a70399-13e1-4ea7-b2cd-5a587410bf53", "name": "", "x": 38.60650078143132, "y": -122.45471221720932, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1aacea55-115d-46c3-9590-725cf5040f38", "name": "p1rlv16200", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "84a70399-13e1-4ea7-b2cd-5a587410bf53"}}}}, {"uuid": "644491c8-32e3-415d-a8b2-9cdc7acd7dfa", "name": "", "x": 38.606181337381166, "y": -122.4557827336667, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33a848c7-076e-4025-863b-ce9151bcc3ac", "name": "p1rdm16630", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "644491c8-32e3-415d-a8b2-9cdc7acd7dfa"}}}}, {"uuid": "1cd42c9f-87d5-443d-bc3d-baf635075a0e", "name": "", "x": 38.60633132723502, "y": -122.45509250327417, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b85e180a-8eb4-4acc-a816-d99758cc16ea", "name": "p1rlv16158", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1cd42c9f-87d5-443d-bc3d-baf635075a0e"}}}}, {"uuid": "756f2ab1-9338-45a3-9e5c-bf0de418e671", "name": "", "x": 38.60650742609989, "y": -122.45740736442846, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a742708-0f8b-42d0-a977-b5ce5e36a042", "name": "p1rdt7574lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "756f2ab1-9338-45a3-9e5c-bf0de418e671"}}}}, {"uuid": "b72df13b-b760-4f9c-8e84-7384a4026df1", "name": "", "x": 38.606502198240534, "y": -122.45735394894129, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "74edd9e9-24a5-4b36-8ca8-24ef2fa3e972", "name": "p1rlv16156", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b72df13b-b760-4f9c-8e84-7384a4026df1"}}}}, {"uuid": "bd429532-7ff5-4e19-8118-d02b72b2445d", "name": "", "x": 38.59916576086806, "y": -122.46399319639457, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "56b05024-7907-458d-a5c3-0e54ffbabdb5", "name": "p1rdt7576lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bd429532-7ff5-4e19-8118-d02b72b2445d"}}}}, {"uuid": "7198a865-1cfe-44a8-8fab-751b1cc8a6af", "name": "", "x": 38.59972953494432, "y": -122.46374387036614, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4fb5abb7-dd79-49aa-9185-88a90bb45bc7", "name": "p1rlv16168", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7198a865-1cfe-44a8-8fab-751b1cc8a6af"}}}}, {"uuid": "89474c6b-5738-4943-9265-a4fb35b3a0a5", "name": "", "x": 38.603712525417045, "y": -122.46283870922412, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4d00b7fe-0384-4c12-a0cf-8895458d3b80", "name": "p1rdt7579lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "89474c6b-5738-4943-9265-a4fb35b3a0a5"}}}}, {"uuid": "332633b6-3eb5-4d54-8439-cfecf21faba5", "name": "", "x": 38.60368654376888, "y": -122.46279611119927, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cbbe8401-53a1-4ce7-9ce1-02f547055d95", "name": "p1rlv16177", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "332633b6-3eb5-4d54-8439-cfecf21faba5"}}}}, {"uuid": "e75397fa-6344-480e-8b24-b7e3fb47e90b", "name": "", "x": 38.601513560330964, "y": -122.46255652294417, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "abc940b0-c9f5-4582-adaf-ad7f4a79a35f", "name": "p1rdt7588lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e75397fa-6344-480e-8b24-b7e3fb47e90b"}}}}, {"uuid": "1dbfb486-355e-48bb-9547-1c5af9aab2e8", "name": "", "x": 38.601499761325734, "y": -122.46260754027634, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0ca42395-8d67-4e83-80ec-159cacb490f8", "name": "p1rlv16206", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1dbfb486-355e-48bb-9547-1c5af9aab2e8"}}}}, {"uuid": "f01e60a2-6edb-4fa2-90ef-fa24804682ad", "name": "", "x": 38.63266298601826, "y": -122.4216856102529, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "53e9cf92-1c91-428f-bdff-64257257ad5b", "name": "p1rdt7589lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f01e60a2-6edb-4fa2-90ef-fa24804682ad"}}}}, {"uuid": "4e04d8fd-20ec-4f89-8bbf-cf16549031aa", "name": "", "x": 38.632738611285475, "y": -122.42182684518295, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9fd05f3c-df77-45bc-8686-458b681a3d08", "name": "p1rlv16210", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4e04d8fd-20ec-4f89-8bbf-cf16549031aa"}}}}, {"uuid": "6dea6e95-aba5-4fce-b04c-34f7c28df0ab", "name": "", "x": 38.63262911078122, "y": -122.4215519854009, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "56b91b3f-dfdd-41bf-9d2e-a8183077c752", "name": "p1rlv16235", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6dea6e95-aba5-4fce-b04c-34f7c28df0ab"}}}}, {"uuid": "226e95df-79cb-49c6-99eb-7ce9f9be1eda", "name": "", "x": 38.63109043622211, "y": -122.42673165565434, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ff1e0d26-d845-43c3-9aaf-01d1c007b9a1", "name": "p1rdt7598lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "226e95df-79cb-49c6-99eb-7ce9f9be1eda"}}}}, {"uuid": "a34d4271-e724-4b08-9a1e-9e75013aa774", "name": "", "x": 38.631104804579536, "y": -122.42678243753235, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b9761003-33fa-482a-967b-b508ab67c19f", "name": "p1rlv16221", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a34d4271-e724-4b08-9a1e-9e75013aa774"}}}}, {"uuid": "7115795f-d38c-435c-bd32-d79fd0c3e2be", "name": "", "x": 38.59926349646212, "y": -122.48320976110043, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d838502-3769-4d70-839b-26fd628ce478", "name": "p1rdt7599lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7115795f-d38c-435c-bd32-d79fd0c3e2be"}}}}, {"uuid": "c3f465b9-0d5a-4166-b70d-0b31c3a84cab", "name": "", "x": 38.59924968840877, "y": -122.4832607729825, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4809afc1-2d3d-491d-80e5-9cd4e8da08f2", "name": "p1rlv16222", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c3f465b9-0d5a-4166-b70d-0b31c3a84cab"}}}}, {"uuid": "7e356edd-9a1e-4a20-b1e2-05ff729a0ab9", "name": "", "x": 38.63045512607571, "y": -122.42581761149648, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d3488ff0-696f-4180-bc70-41ff37f9c365", "name": "p1rdt7605lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7e356edd-9a1e-4a20-b1e2-05ff729a0ab9"}}}}, {"uuid": "dba9df17-dbb7-40e0-8389-32f86a83d0ce", "name": "", "x": 38.63042913104939, "y": -122.4257750112935, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b8767650-39c5-4d4a-80ce-af408c246599", "name": "p1rlv16228", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dba9df17-dbb7-40e0-8389-32f86a83d0ce"}}}}, {"uuid": "ba3209f3-ddc3-42d2-9fb6-73352cdcc890", "name": "", "x": 38.62802329409922, "y": -122.420609783299, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0fdfea70-187a-4bbc-ba3f-69cb74c4d5c5", "name": "p1rdt7612lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ba3209f3-ddc3-42d2-9fb6-73352cdcc890"}}}}, {"uuid": "f517027f-3138-4efe-b5c1-6b209dd16b66", "name": "", "x": 38.62799729719169, "y": -122.42056718642846, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9642fa30-e5f7-42f1-8fda-ab75a265d25a", "name": "p1rlv16239", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f517027f-3138-4efe-b5c1-6b209dd16b66"}}}}, {"uuid": "eae6de67-8927-41f1-b2b4-566cb14958c4", "name": "", "x": 38.56073046128886, "y": -122.50852889395006, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "269e9ba5-bc54-4cbd-9140-4b1bea74fc53", "name": "p1rdt7615lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eae6de67-8927-41f1-b2b4-566cb14958c4"}}}}, {"uuid": "dfa27b4c-8f60-4a6f-8e32-e240e90c01fa", "name": "", "x": 38.56046440447144, "y": -122.50887900476087, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e82036d9-e6c8-42c3-b45b-30bef6902bbc", "name": "p1rlv16242", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dfa27b4c-8f60-4a6f-8e32-e240e90c01fa"}}}}, {"uuid": "6ee0bd86-1680-444a-a29c-1dc0ca96d7f2", "name": "", "x": 38.56073966572795, "y": -122.50857474214654, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "978533ca-ef57-4cb6-9e7f-b3c6d1bbd7d5", "name": "p1rlv16261", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6ee0bd86-1680-444a-a29c-1dc0ca96d7f2"}}}}, {"uuid": "47348236-35ea-4e14-9db4-04f53ff4cb88", "name": "", "x": 38.562034810135316, "y": -122.51158858609705, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "65458dd3-50e0-48d3-a0db-0015707d3cea", "name": "p1rdm16694", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "47348236-35ea-4e14-9db4-04f53ff4cb88"}}}}, {"uuid": "51f24211-6a02-4069-9407-7162a0e828bf", "name": "", "x": 38.56202613361287, "y": -122.51166899029859, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "268549c6-0c8b-44ac-b933-316b36645366", "name": "p1rlv16253", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "51f24211-6a02-4069-9407-7162a0e828bf"}}}}, {"uuid": "84b11cd9-6ad0-4a24-a958-715b6fc7be35", "name": "", "x": 38.56186788179104, "y": -122.51113810898512, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6af13868-ecb1-4110-be3f-537741287035", "name": "p1rdt7616lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "84b11cd9-6ad0-4a24-a958-715b6fc7be35"}}}}, {"uuid": "7d5808cb-7939-481a-8de5-91a65946aa43", "name": "", "x": 38.56181598959075, "y": -122.51098173878029, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "83d31d7a-8900-4f2e-9183-8a10f07e2bdd", "name": "p1rdm16695", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7d5808cb-7939-481a-8de5-91a65946aa43"}}}}, {"uuid": "9e3cb4e1-00a3-40b7-a310-e1d3288381c9", "name": "", "x": 38.561797870283755, "y": -122.51095890578438, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c620d4b9-a849-4bf6-b108-118836866602", "name": "p1rlv16270", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9e3cb4e1-00a3-40b7-a310-e1d3288381c9"}}}}, {"uuid": "301d7474-7394-4adb-83c5-de8da079d030", "name": "", "x": 38.56163474835187, "y": -122.51074193179929, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "766647d4-7c3c-4058-b30c-dbc593b88ecb", "name": "p1rdm16693", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "301d7474-7394-4adb-83c5-de8da079d030"}}}}, {"uuid": "ee0e3777-b5c5-4c55-8a82-0a2aa0ec819c", "name": "", "x": 38.56165286770099, "y": -122.51076476468909, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "20818cc7-617e-4ab7-8f7c-31eea6496a02", "name": "p1rlv16243", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ee0e3777-b5c5-4c55-8a82-0a2aa0ec819c"}}}}, {"uuid": "effa99d5-0528-4214-9f65-c85da4d99cb0", "name": "", "x": 38.563138374369146, "y": -122.50973711139406, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4be4af94-fee7-40d6-9061-9a0fe0e7377e", "name": "p1rdt7617lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "effa99d5-0528-4214-9f65-c85da4d99cb0"}}}}, {"uuid": "daf01f10-6d6c-445b-9fdd-f5006c1c211b", "name": "", "x": 38.56309099533974, "y": -122.50985972349204, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e0164339-acc1-4b95-aa31-3af42cf943f7", "name": "p1rlv16244", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "daf01f10-6d6c-445b-9fdd-f5006c1c211b"}}}}, {"uuid": "53d2cce6-a3d7-4ce1-b40e-37e98b714398", "name": "", "x": 38.563135188623946, "y": -122.50965281749981, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4d1fb8eb-57aa-4366-afe5-b79174f3a4c7", "name": "p1rdm16697", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "53d2cce6-a3d7-4ce1-b40e-37e98b714398"}}}}, {"uuid": "767e8d01-6f03-4aab-bbdd-e7516fac9674", "name": "", "x": 38.563267563002256, "y": -122.50965942729142, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "04647fad-19dc-4ed8-8820-aa312674145c", "name": "p1rlv16255", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "767e8d01-6f03-4aab-bbdd-e7516fac9674"}}}}, {"uuid": "e6e642bd-5a02-4bab-9654-a8d16102dcd4", "name": "", "x": 38.64626899154278, "y": -122.41892573953396, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "795f4296-7c54-4e96-8468-52903af39708", "name": "p1rdm16699", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e6e642bd-5a02-4bab-9654-a8d16102dcd4"}}}}, {"uuid": "75f5fcc1-c81f-49ae-a4c9-1fe46bb70e41", "name": "", "x": 38.64646884092825, "y": -122.4192458831601, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5c6a5f39-0654-4e73-8050-c6c4ad9d54e6", "name": "p1rlv16252", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "75f5fcc1-c81f-49ae-a4c9-1fe46bb70e41"}}}}, {"uuid": "86e7ee95-7549-4c76-908c-030d93ec9795", "name": "", "x": 38.64614340209092, "y": -122.41904166679946, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "acb015a8-a9f8-492b-ab3f-b107bd956f91", "name": "p1rdm16698", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "86e7ee95-7549-4c76-908c-030d93ec9795"}}}}, {"uuid": "cb0a2f85-7a50-463d-bb48-789ac1c19a51", "name": "", "x": 38.646106728547146, "y": -122.41891555875277, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3783c838-b72e-42cd-8b0b-3005bca3cf5e", "name": "p1rlv16245", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb0a2f85-7a50-463d-bb48-789ac1c19a51"}}}}, {"uuid": "4a2288ec-9b7d-4dba-b1ba-c617235fedd4", "name": "", "x": 38.64641551310019, "y": -122.41882510751344, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "49f37435-54fc-42b4-baba-94f0611c8c76", "name": "p1rdt7618lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4a2288ec-9b7d-4dba-b1ba-c617235fedd4"}}}}, {"uuid": "25ca9092-333a-4071-952e-beb0df30161f", "name": "", "x": 38.64677146238617, "y": -122.41848500827774, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "73030a97-0574-4802-80d1-14fefeafa63a", "name": "p1rdm16700", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "25ca9092-333a-4071-952e-beb0df30161f"}}}}, {"uuid": "7a39814a-94fc-4129-9a0b-165f7813be33", "name": "", "x": 38.64669874248704, "y": -122.41835919083687, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "19aeb510-ac0e-4279-8db0-8de282beccc8", "name": "p1rlv16267", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7a39814a-94fc-4129-9a0b-165f7813be33"}}}}, {"uuid": "0630d605-bb3f-43f0-b776-d4ada20f11aa", "name": "", "x": 38.56141189302572, "y": -122.50849775727877, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3a205379-48f9-444c-baf8-dc84fc9c6d8a", "name": "p1rdt7619lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0630d605-bb3f-43f0-b776-d4ada20f11aa"}}}}, {"uuid": "15292442-11f0-4f4b-8858-9f1431a817b7", "name": "", "x": 38.561113439797154, "y": -122.50892049903847, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dd2dc2db-787a-4732-bae4-01186082a92d", "name": "p1rlv16246", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "15292442-11f0-4f4b-8858-9f1431a817b7"}}}}, {"uuid": "7388c6fa-ce1e-47ab-a43a-73bf44b2dacd", "name": "", "x": 38.56276173762939, "y": -122.51370313533468, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9af91c50-929d-4ac6-9272-7c44d17a0094", "name": "p1rdt7620lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7388c6fa-ce1e-47ab-a43a-73bf44b2dacd"}}}}, {"uuid": "90982ae6-16f2-483c-944a-57039dcebb07", "name": "", "x": 38.56259236273701, "y": -122.5134672071745, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a8d5e9b7-dc95-41f9-8547-99d5e2eba874", "name": "p1rlv16247", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "90982ae6-16f2-483c-944a-57039dcebb07"}}}}, {"uuid": "5106ecc5-1a2f-41bc-b6c8-3ae15176b9e9", "name": "", "x": 38.56176044882826, "y": -122.50995307443512, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60f0bddf-6e4b-495c-a98d-f3940d69a5e9", "name": "p1rdt7621lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5106ecc5-1a2f-41bc-b6c8-3ae15176b9e9"}}}}, {"uuid": "97ebfd06-ca63-41d2-ae54-9e9c8da085a2", "name": "", "x": 38.561693460357375, "y": -122.50969704739022, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "feb24768-feab-40f0-acc3-0b2bb500133a", "name": "p1rlv16248", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "97ebfd06-ca63-41d2-ae54-9e9c8da085a2"}}}}, {"uuid": "5ced85f7-f461-4760-989d-da3f0b33b912", "name": "", "x": 38.63755744615242, "y": -122.465948154899, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e2075fb-9691-447e-9a73-f88649310bc1", "name": "p1rdt7624lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ced85f7-f461-4760-989d-da3f0b33b912"}}}}, {"uuid": "5bc50684-7a0d-436b-972b-fe999f8f51db", "name": "", "x": 38.63754827273094, "y": -122.46600084949326, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32a9302f-2d40-4c2a-bde9-e4039694fed7", "name": "p1rlv16256", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5bc50684-7a0d-436b-972b-fe999f8f51db"}}}}, {"uuid": "cbff86f3-b1ca-4bb9-b929-b7706ddb1140", "name": "", "x": 38.56312481406225, "y": -122.50942641108807, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a6b1e3b6-ce3a-4ad6-a046-6608530b2ec2", "name": "p1rdt7625lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cbff86f3-b1ca-4bb9-b929-b7706ddb1140"}}}}, {"uuid": "ca85a7fc-d2bf-4ae4-bde9-edd5d0c42655", "name": "", "x": 38.56379044489856, "y": -122.50902854183389, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "935c99a6-bef6-4417-872c-0685011c440c", "name": "p1rlv16257", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ca85a7fc-d2bf-4ae4-bde9-edd5d0c42655"}}}}, {"uuid": "9094241e-f572-4ca2-a2f7-73618f62dfb3", "name": "", "x": 38.5622508740622, "y": -122.51221444287553, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "56f8eed1-77ae-4d65-80aa-7ae148350333", "name": "p1rdt7626lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9094241e-f572-4ca2-a2f7-73618f62dfb3"}}}}, {"uuid": "40f7128c-ed34-4a06-8927-100507e5ed27", "name": "", "x": 38.562245476566225, "y": -122.51240209551142, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fdf35585-e2b3-4463-a6a8-acb352f25003", "name": "p1rlv16260", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "40f7128c-ed34-4a06-8927-100507e5ed27"}}}}, {"uuid": "6de641fa-7013-4aa1-9223-c0f5bcdcc02b", "name": "", "x": 38.56232619942912, "y": -122.51230972629801, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fc746539-662a-4fe4-8774-6ba2dc538118", "name": "p1rlv16269", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6de641fa-7013-4aa1-9223-c0f5bcdcc02b"}}}}, {"uuid": "00cd9384-7f49-423e-b329-029dcc4041a7", "name": "", "x": 38.56258212321864, "y": -122.51385355991457, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "90d8891c-6e6d-46b9-8f88-acc9453c6541", "name": "p1rdt7627lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "00cd9384-7f49-423e-b329-029dcc4041a7"}}}}, {"uuid": "124e10ea-1bf0-41b7-a040-a7913288ddea", "name": "", "x": 38.562602805051284, "y": -122.51381147731462, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2797febc-f5e7-4cb3-b26f-ace990dc6920", "name": "p1rlv16262", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "124e10ea-1bf0-41b7-a040-a7913288ddea"}}}}, {"uuid": "e8a8f728-47d8-4295-b6f3-42e071ca524f", "name": "", "x": 38.56133819555369, "y": -122.51026584276248, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ad2599f-313b-49c6-abaa-19177e1a9edc", "name": "p1rdt7630lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e8a8f728-47d8-4295-b6f3-42e071ca524f"}}}}, {"uuid": "6fb5ec76-7803-4c02-9ae4-bb649280dfc2", "name": "", "x": 38.56092456814972, "y": -122.50968682475795, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e8835446-b333-4be9-96bd-57ff9d01ebd3", "name": "p1rlv16266", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6fb5ec76-7803-4c02-9ae4-bb649280dfc2"}}}}, {"uuid": "86853692-b205-4618-a7a5-8176c8cb9876", "name": "", "x": 38.5616967364387, "y": -122.50900438404291, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4861056b-b634-4900-94bb-d6c995387351", "name": "p1rdt7631lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "86853692-b205-4618-a7a5-8176c8cb9876"}}}}, {"uuid": "eb7a2999-86c8-4f6f-a010-1615b513d664", "name": "", "x": 38.561466725079015, "y": -122.50935425276774, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ba6ebe7f-b6b9-4f89-8bbf-7bffd63e10ef", "name": "p1rlv16268", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eb7a2999-86c8-4f6f-a010-1615b513d664"}}}}, {"uuid": "3398e448-e018-40e6-a50b-4504d0b77a7b", "name": "", "x": 38.637592171075106, "y": -122.45349611008078, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bfa76dc8-4007-4e52-9692-2eec7cb574e0", "name": "p1rdt7699lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3398e448-e018-40e6-a50b-4504d0b77a7b"}}}}, {"uuid": "dcb8b703-4cb4-4039-9993-9d9b04402c41", "name": "", "x": 38.63759072492407, "y": -122.45258089846875, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f58421d6-268b-417f-a579-c9c51d010697", "name": "p1rlv16416", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dcb8b703-4cb4-4039-9993-9d9b04402c41"}}}}, {"uuid": "1e841da1-29f5-41d4-8ba5-c88ecf63ee18", "name": "", "x": 38.63777525230912, "y": -122.45349869276687, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e60bfe9e-d2fa-4576-87f3-0a866b88d07d", "name": "p1rdm16862", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1e841da1-29f5-41d4-8ba5-c88ecf63ee18"}}}}, {"uuid": "37827724-bd74-4a74-8d3f-92058b8bebf4", "name": "", "x": 38.63771801473168, "y": -122.45282121950886, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9d908890-4fe4-4349-92de-464c4165b185", "name": "p1rlv16395", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "37827724-bd74-4a74-8d3f-92058b8bebf4"}}}}, {"uuid": "8e7d6de1-f6ed-4806-9ef0-24d1d6dbbf11", "name": "", "x": 38.636816322579385, "y": -122.45331816430568, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0cc95d09-c799-488e-81e8-50326a7da1ea", "name": "p1rdt7701lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8e7d6de1-f6ed-4806-9ef0-24d1d6dbbf11"}}}}, {"uuid": "db27e2bb-978f-4758-9ed3-644b0176ec4d", "name": "", "x": 38.63714867725408, "y": -122.45248085191842, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "323373a9-8e7d-4fb4-8970-dcc0e6d26c98", "name": "p1rlv16397", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "db27e2bb-978f-4758-9ed3-644b0176ec4d"}}}}, {"uuid": "5762879f-fed8-408b-b69c-2693dac42fd6", "name": "", "x": 38.634315239366806, "y": -122.45108169056164, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8ef392d6-b408-4a7f-8a67-9fe43e1df582", "name": "p1rdt7704lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5762879f-fed8-408b-b69c-2693dac42fd6"}}}}, {"uuid": "dbfb266a-0b63-477e-8649-ac94dbb2b196", "name": "", "x": 38.63384513963928, "y": -122.45197349911196, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "571a4c92-95b6-4bc0-a25d-0d9239a41a89", "name": "p1rlv20070", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dbfb266a-0b63-477e-8649-ac94dbb2b196"}}}}, {"uuid": "0e217484-8e6b-4d4d-af52-4413a7a594c3", "name": "", "x": 38.634430184568174, "y": -122.45121471447422, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0797f1d0-3499-4f88-a749-fc576240f791", "name": "p1rdm16872", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0e217484-8e6b-4d4d-af52-4413a7a594c3"}}}}, {"uuid": "fa4839ee-ecfc-4d14-8f46-c4b0651ff87c", "name": "", "x": 38.63430515491296, "y": -122.45145694554178, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eeb598c2-f0b9-44df-bfaa-be66e4dc3920", "name": "p1rlv16401", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa4839ee-ecfc-4d14-8f46-c4b0651ff87c"}}}}, {"uuid": "a9f961bd-cefe-4dae-ab39-0e189f5bff80", "name": "", "x": 38.63414958801971, "y": -122.4509525977873, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c5e00667-6368-49d3-a5dd-c574c79dba21", "name": "p1rdm16873", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a9f961bd-cefe-4dae-ab39-0e189f5bff80"}}}}, {"uuid": "1481206c-4e04-432b-a9f1-67ab90498892", "name": "", "x": 38.63394415582507, "y": -122.45134480308546, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d0b689f0-d4b1-4419-bff8-f72436625c60", "name": "p1rlv20068", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1481206c-4e04-432b-a9f1-67ab90498892"}}}}, {"uuid": "e97df275-6dc5-479d-a4d3-e0c412bde049", "name": "", "x": 38.633795319458095, "y": -122.45167161174345, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3f0e3c74-2d63-4612-b0e5-d986ebee0086", "name": "p1rlv20069", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e97df275-6dc5-479d-a4d3-e0c412bde049"}}}}, {"uuid": "a1266fd6-c0ee-49b8-82fc-cc6fce9a2e1b", "name": "", "x": 38.63640935476333, "y": -122.45301103214067, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "59a62487-c709-428e-9e97-c7c285a1305c", "name": "p1rdt7712lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a1266fd6-c0ee-49b8-82fc-cc6fce9a2e1b"}}}}, {"uuid": "5ad66ee7-9785-4523-a2f9-c52cd5d0b5a8", "name": "", "x": 38.636725727850084, "y": -122.45261045736181, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "99f97a6b-4e94-4a35-ad00-12e7004ab5e3", "name": "p1rlv16412", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ad66ee7-9785-4523-a2f9-c52cd5d0b5a8"}}}}, {"uuid": "3d37469f-053d-4c17-a339-a46fa2bfeb6a", "name": "", "x": 38.634298404574224, "y": -122.452544518945, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f6d10a4e-e7bc-4448-bca3-a5f2117b6198", "name": "p1rdt7718lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3d37469f-053d-4c17-a339-a46fa2bfeb6a"}}}}, {"uuid": "74a7237e-d8c7-411c-83b2-d4013f798b7a", "name": "", "x": 38.63419311757913, "y": -122.45254929248175, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f367b63c-c4cb-4810-a270-8bd0153b7b32", "name": "p1rlv16422", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "74a7237e-d8c7-411c-83b2-d4013f798b7a"}}}}, {"uuid": "4bac0a18-2477-438a-94a0-812507fc8fcd", "name": "", "x": 38.634445386111494, "y": -122.4525358843223, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c2242f1c-542f-4c1f-b3e6-19482cccde8d", "name": "p1rlv16424", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4bac0a18-2477-438a-94a0-812507fc8fcd"}}}}, {"uuid": "0a20861b-7864-4182-b71d-404098b80998", "name": "", "x": 38.65497278403905, "y": -122.46523250990784, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "96dcd934-01a0-4719-89bc-a18430edf179", "name": "p1rdt7735lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a20861b-7864-4182-b71d-404098b80998"}}}}, {"uuid": "fe1bfd41-fe22-4cbe-ab09-2fa1f2f47f5a", "name": "", "x": 38.65486042898651, "y": -122.46493056100381, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8e090544-3c8e-4716-9dae-0b311a1017ea", "name": "p1rlv16445", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fe1bfd41-fe22-4cbe-ab09-2fa1f2f47f5a"}}}}, {"uuid": "63c6b927-d3dc-4646-aec2-7061f58953c5", "name": "", "x": 38.653199252282036, "y": -122.46489297492766, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5ed564b5-8d49-4ff7-94c2-b245981472e8", "name": "p1rdt7790lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "63c6b927-d3dc-4646-aec2-7061f58953c5"}}}}, {"uuid": "98406b17-db64-435a-89ca-371b67b5b8e4", "name": "", "x": 38.65291599440307, "y": -122.46539322901351, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "53d578d8-8492-471b-8f66-233e489a3652", "name": "p1rlv16570", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "98406b17-db64-435a-89ca-371b67b5b8e4"}}}}, {"uuid": "38850062-35c5-42c4-8473-53df10d67257", "name": "", "x": 38.62241982511306, "y": -122.43971932407153, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b9dd5bb5-1410-4635-8a85-d23d7c3e55ad", "name": "p1rdt7954lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "38850062-35c5-42c4-8473-53df10d67257"}}}}, {"uuid": "40b7450c-e6b0-4a78-af62-e7c24b136327", "name": "", "x": 38.62265588015955, "y": -122.43879451092451, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7578563f-d4b3-423b-a8f5-3ee91a042d19", "name": "p1rlv16905", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "40b7450c-e6b0-4a78-af62-e7c24b136327"}}}}, {"uuid": "36950be0-4fd3-451a-9fac-8409812f4199", "name": "", "x": 38.622543574694504, "y": -122.43980628940227, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e982887d-97c6-4af5-b536-a15a372b3379", "name": "p1rdm17416", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "36950be0-4fd3-451a-9fac-8409812f4199"}}}}, {"uuid": "f39b6cba-092a-4569-9a47-5b35d3249d8e", "name": "", "x": 38.62287193593768, "y": -122.43874687668992, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4faf40b9-9ade-45b5-ade8-3f1833605cd1", "name": "p1rlv16882", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f39b6cba-092a-4569-9a47-5b35d3249d8e"}}}}, {"uuid": "967a9ca5-e96e-430d-84d9-5cdc3b729f49", "name": "", "x": 38.62281759636039, "y": -122.43998044342054, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3a96167-4b09-49c9-baf7-4fb588ecb002", "name": "p1rdt7973lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "967a9ca5-e96e-430d-84d9-5cdc3b729f49"}}}}, {"uuid": "756b813f-44fd-4a19-ba1d-6f9e311b850f", "name": "", "x": 38.623145420142684, "y": -122.43939954007212, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c2308dc3-d10b-4049-862d-caf3356fa9a7", "name": "p1rlv16912", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "756b813f-44fd-4a19-ba1d-6f9e311b850f"}}}}, {"uuid": "edeba34e-bd5b-47af-bada-d48b971f09c9", "name": "", "x": 38.62309085570953, "y": -122.43929657626467, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "11a633b0-2b09-4c66-94d4-d1c24cdd9cf5", "name": "p1rlv16988", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "edeba34e-bd5b-47af-bada-d48b971f09c9"}}}}, {"uuid": "29f78aa6-2219-41f0-b8fd-73cfb14343d6", "name": "", "x": 38.622914421161234, "y": -122.44009059423414, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "53ed549a-9c24-4bdd-9e40-aee5308d8120", "name": "p1rdm17505", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "29f78aa6-2219-41f0-b8fd-73cfb14343d6"}}}}, {"uuid": "b591bafa-ff50-4f54-a8fb-5aca6caab3c9", "name": "", "x": 38.62313800426249, "y": -122.43973273911827, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4c570ef7-c483-4c1e-b0fd-8712e8e9a7cd", "name": "p1rlv16904", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b591bafa-ff50-4f54-a8fb-5aca6caab3c9"}}}}, {"uuid": "b8e4d113-43ab-498e-ba02-2cda8df4a829", "name": "", "x": 38.618288153419634, "y": -122.43508780454101, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cb63be48-94ec-4c9f-9991-77892e14171b", "name": "p1rdt7983lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b8e4d113-43ab-498e-ba02-2cda8df4a829"}}}}, {"uuid": "786f1d10-0412-4963-9e25-0d1e156451c2", "name": "", "x": 38.6178110723834, "y": -122.43578826842699, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "07e01053-37f3-4b9f-a9f1-d51bccd29803", "name": "p1rlv16919", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "786f1d10-0412-4963-9e25-0d1e156451c2"}}}}, {"uuid": "ecbeb3c5-deaf-40f8-b0f7-c5efa49d8122", "name": "", "x": 38.617981016890134, "y": -122.43552274050253, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dfa28657-cd8e-4700-a189-83e021f77bee", "name": "p1rlv17033", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ecbeb3c5-deaf-40f8-b0f7-c5efa49d8122"}}}}, {"uuid": "9b9c7472-9dea-4ebe-8b54-92c0d3484b0a", "name": "", "x": 38.60009989462982, "y": -122.45165246954828, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "415fe6e9-953e-40f6-8ae8-43834e4e6ce4", "name": "p1rdt7986lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9b9c7472-9dea-4ebe-8b54-92c0d3484b0a"}}}}, {"uuid": "ae9eb3b3-537f-40c2-943f-3469e0711386", "name": "", "x": 38.60019584777296, "y": -122.45157886471317, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ce315d98-1556-429b-aebb-0c868892396a", "name": "p1rlv16922", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ae9eb3b3-537f-40c2-943f-3469e0711386"}}}}, {"uuid": "e1274621-2f83-4c64-9c96-f50c8d474a6c", "name": "", "x": 38.5999461596242, "y": -122.45214347781915, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7dff1455-5154-429f-a33f-044d8501281d", "name": "p1rlv16957", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e1274621-2f83-4c64-9c96-f50c8d474a6c"}}}}, {"uuid": "85b83e09-ec12-486f-ad2e-0555a1ba557f", "name": "", "x": 38.60009505177635, "y": -122.45122362894173, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "19130741-0fe1-4a12-8a55-96355609bccb", "name": "p1rlv17063", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "85b83e09-ec12-486f-ad2e-0555a1ba557f"}}}}, {"uuid": "6897a9e4-802b-4dc9-a6ca-c8eca130dd9c", "name": "", "x": 38.61708288860949, "y": -122.43744053773406, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "94f12107-697c-4278-95e0-32b6eb49fdb3", "name": "p1rdt7988lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6897a9e4-802b-4dc9-a6ca-c8eca130dd9c"}}}}, {"uuid": "999335b2-ae36-40cb-9fd3-b2738191bb3d", "name": "", "x": 38.61700772395571, "y": -122.43739120644287, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ba1d053-4462-4eb4-aca6-5ede38aa283c", "name": "p1rlv16926", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "999335b2-ae36-40cb-9fd3-b2738191bb3d"}}}}, {"uuid": "52cf2f27-de63-46c8-92e2-0e220ca503d5", "name": "", "x": 38.6171461348718, "y": -122.43747450374505, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5439f343-8176-4d92-99d4-bb9209817f6b", "name": "p1rlv17106", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "52cf2f27-de63-46c8-92e2-0e220ca503d5"}}}}, {"uuid": "f1373852-4d12-4fab-86ca-a37b50a04f22", "name": "", "x": 38.62030446603571, "y": -122.4376486590166, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f5b22c57-7912-4e9f-9b06-6a8ff706a58d", "name": "p1rdt8012lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f1373852-4d12-4fab-86ca-a37b50a04f22"}}}}, {"uuid": "0a779003-8296-47e1-b30a-ece8f8025987", "name": "", "x": 38.619635701851216, "y": -122.43854235774572, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "57e8aa34-3967-4f22-a978-cb513c49c153", "name": "p1rlv16992", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a779003-8296-47e1-b30a-ece8f8025987"}}}}, {"uuid": "3b30dab7-8ea2-4d20-afae-2bb1a6efded1", "name": "", "x": 38.61994945069005, "y": -122.43819529796752, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bd48a076-5f8f-426a-b294-183700d1a123", "name": "p1rlv17069", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3b30dab7-8ea2-4d20-afae-2bb1a6efded1"}}}}, {"uuid": "a2a5e5d8-edf7-451c-b710-08f3ebe5620f", "name": "", "x": 38.60637102325893, "y": -122.45140950104778, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a6c5d7ff-cfcd-4b30-98db-eb44a95d6841", "name": "p1rdt8015lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a2a5e5d8-edf7-451c-b710-08f3ebe5620f"}}}}, {"uuid": "6a96ff2a-cd9b-4d06-8c13-ef04fa2bd59d", "name": "", "x": 38.60632273742159, "y": -122.45132550281518, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f23214ee-3032-4403-9084-8117e89cb1cf", "name": "p1rlv17001", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a96ff2a-cd9b-4d06-8c13-ef04fa2bd59d"}}}}, {"uuid": "d18a87e9-8f1c-4a7a-bf3f-195c6b8f25a2", "name": "", "x": 38.60636860276844, "y": -122.45149742797311, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "213e6d98-ad57-4034-b2d0-4b096554cac2", "name": "p1rlv17028", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d18a87e9-8f1c-4a7a-bf3f-195c6b8f25a2"}}}}, {"uuid": "74928a51-a3eb-4475-a089-b643f8e3cddd", "name": "", "x": 38.620582059906845, "y": -122.43797607749299, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "972fe574-f88e-4a8d-8845-d5baa2f378a7", "name": "p1rdt8034lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "74928a51-a3eb-4475-a089-b643f8e3cddd"}}}}, {"uuid": "57807a14-3fcd-490d-a976-2296f5ca4a86", "name": "", "x": 38.620214408134636, "y": -122.43835802321873, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "92aff718-b70f-4ea4-b38b-fae69a470c58", "name": "p1rlv17059", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "57807a14-3fcd-490d-a976-2296f5ca4a86"}}}}, {"uuid": "652294b0-563d-4bfd-b434-dcdbf4f1f2c8", "name": "", "x": 38.59894295708058, "y": -122.46830816449578, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9951633b-4311-4ca2-9316-3801be13fe97", "name": "p1rdt8149lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "652294b0-563d-4bfd-b434-dcdbf4f1f2c8"}}}}, {"uuid": "24cd4106-fd1e-4e94-a044-53af52c6d2ca", "name": "", "x": 38.598821308346544, "y": -122.46812594296912, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d9778ed5-f0c0-44de-b0d4-60659a54fa3b", "name": "p1rlv17319", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "24cd4106-fd1e-4e94-a044-53af52c6d2ca"}}}}, {"uuid": "f10ee951-5720-4c53-bd7f-7ff21679759b", "name": "", "x": 38.598867566369016, "y": -122.46838972837861, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4970bc03-bc57-4a42-b0cb-66002af1709e", "name": "p1rlv17334", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f10ee951-5720-4c53-bd7f-7ff21679759b"}}}}, {"uuid": "be323039-e11a-4d50-ae15-10c1ce1c9187", "name": "", "x": 38.59870152218132, "y": -122.4669250043453, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6cd1ae47-6aaa-4b57-ba44-1e74f6ea54b7", "name": "p1rdt8150lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be323039-e11a-4d50-ae15-10c1ce1c9187"}}}}, {"uuid": "2876bba6-9299-413f-b90c-6f858847f3c5", "name": "", "x": 38.59827116190417, "y": -122.46741050201447, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "79991b02-c0f1-4b9b-a55e-e9b4ff7c17d9", "name": "p1rlv17320", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2876bba6-9299-413f-b90c-6f858847f3c5"}}}}, {"uuid": "7dbc0a5b-096f-467d-8654-2443b4048e03", "name": "", "x": 38.599111058885946, "y": -122.46644716803104, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6ceb2d77-2da7-44df-9f28-69ed35835775", "name": "p1rlv17326", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7dbc0a5b-096f-467d-8654-2443b4048e03"}}}}, {"uuid": "7e3afdac-e798-4f5f-a6bf-8b16a3ecc303", "name": "", "x": 38.599727655355764, "y": -122.4681198081272, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75a8deb5-b46b-4d4c-876c-b44b2258a6fa", "name": "p1rdt8151lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7e3afdac-e798-4f5f-a6bf-8b16a3ecc303"}}}}, {"uuid": "65e01278-ee98-422b-a1ee-5e7071567570", "name": "", "x": 38.599692587118206, "y": -122.46815246602429, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "00ed745d-78ae-47f6-b6ef-4edf8794ca6a", "name": "p1rdt8151lv-p1rlv17321x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65e01278-ee98-422b-a1ee-5e7071567570"}}}}, {"uuid": "e413bf90-133e-4824-8fae-b54739e28318", "name": "", "x": 38.599654808831716, "y": -122.46817784954497, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "94ce8ee2-6f57-407a-93e9-c06f79d66262", "name": "p1rdt8151lv-p1rlv17321xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e413bf90-133e-4824-8fae-b54739e28318"}}}}, {"uuid": "b16cfa2e-327a-4cd1-af35-0b3f8d8e6192", "name": "", "x": 38.59971750379885, "y": -122.46702835755418, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ce41ac7c-06c5-435a-957d-c9dda83c1893", "name": "p1rlv17321", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b16cfa2e-327a-4cd1-af35-0b3f8d8e6192"}}}}, {"uuid": "51b25475-572c-43ef-b08b-4bc4bc2e516d", "name": "", "x": 38.599821698957996, "y": -122.46814152774704, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "abb24254-be79-45d4-8d9b-246b3e89c00f", "name": "p1rlv20188", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "51b25475-572c-43ef-b08b-4bc4bc2e516d"}}}}, {"uuid": "73645010-aad0-4777-9ab9-4d588ae8adc5", "name": "", "x": 38.59932106464093, "y": -122.4698880830305, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7a542ca5-b24e-44dc-8b68-c00aa024afad", "name": "p1rdt8153lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "73645010-aad0-4777-9ab9-4d588ae8adc5"}}}}, {"uuid": "bcc547e6-c25f-4156-a23e-52ef6e3c66a3", "name": "", "x": 38.59930726241313, "y": -122.4699390974389, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9b96606c-9336-4299-be8d-295c84943a9d", "name": "p1rlv17325", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bcc547e6-c25f-4156-a23e-52ef6e3c66a3"}}}}, {"uuid": "12a4a536-86b1-4eea-a894-3802183a70e7", "name": "", "x": 38.5995160751222, "y": -122.47116135904078, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32fefbef-e10b-4758-8c2e-ccafad49aa5d", "name": "p1rdt8154lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "12a4a536-86b1-4eea-a894-3802183a70e7"}}}}, {"uuid": "bc792def-db51-4a96-a8b0-19f05e3269c4", "name": "", "x": 38.59950227233904, "y": -122.4712123733502, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a43eb022-d5e0-47c8-aa36-6ca0d212ab07", "name": "p1rlv17328", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bc792def-db51-4a96-a8b0-19f05e3269c4"}}}}, {"uuid": "c3d91646-a40b-40ca-80bb-61f7e6f26a01", "name": "", "x": 38.598945724578684, "y": -122.46814818814434, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "51812cd8-eec8-4862-8413-d25a7e9862dc", "name": "p1rdt8155lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c3d91646-a40b-40ca-80bb-61f7e6f26a01"}}}}, {"uuid": "fc85bc7f-eb62-491d-a8dd-e16c26eaa370", "name": "", "x": 38.59855694337255, "y": -122.46746183798086, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "61ef37c1-f14f-4b79-a428-d51a6f0d076a", "name": "p1rlv17329", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fc85bc7f-eb62-491d-a8dd-e16c26eaa370"}}}}, {"uuid": "85a37c02-3c14-40bb-9d81-588a0997012f", "name": "", "x": 38.59929944436906, "y": -122.4682372527046, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cb2a5041-28a1-4fda-905b-caf53ebbefe3", "name": "p1rdm17903", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "85a37c02-3c14-40bb-9d81-588a0997012f"}}}}, {"uuid": "600dd5af-b1ef-4e7d-9206-2af3992c0b0d", "name": "", "x": 38.599299287824266, "y": -122.46820280233233, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48ad7bb0-8dd7-457a-b77d-6db2071c2fe7", "name": "p1rlv17330", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "600dd5af-b1ef-4e7d-9206-2af3992c0b0d"}}}}, {"uuid": "c6354fad-0bf0-4b9f-8e5b-9393b20d716a", "name": "", "x": 38.59897593725153, "y": -122.46956906444683, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fa6d4429-8a95-4ebd-9e3a-9867734245bd", "name": "p1rdt8157lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c6354fad-0bf0-4b9f-8e5b-9393b20d716a"}}}}, {"uuid": "bafc48cf-5d8c-4306-98a9-d215091f7b50", "name": "", "x": 38.598949958035, "y": -122.46952646674691, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33b66eb9-3b21-4f92-b19b-6a0eef4134d8", "name": "p1rlv17333", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bafc48cf-5d8c-4306-98a9-d215091f7b50"}}}}, {"uuid": "90af01ca-1950-494d-b325-b227d69c91bf", "name": "", "x": 38.64315249575866, "y": -122.47114976892446, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e1dd4660-3cd0-4709-b1ef-1c598e5e39fb", "name": "p1rdt8159lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "90af01ca-1950-494d-b325-b227d69c91bf"}}}}, {"uuid": "fb4f265f-b768-470b-b88f-c854b51fcff9", "name": "", "x": 38.64322634740489, "y": -122.47091189149079, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a5d0a174-d49d-4c7e-a669-092f6408edf4", "name": "p1rlv20480", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fb4f265f-b768-470b-b88f-c854b51fcff9"}}}}, {"uuid": "e08079d3-edd1-4bc8-b081-44dd5362f947", "name": "", "x": 38.64301980977188, "y": -122.47107428162515, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3484e698-3a4e-4a88-aaa3-1dc88cd9ac89", "name": "p1rdm17907", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e08079d3-edd1-4bc8-b081-44dd5362f947"}}}}, {"uuid": "bda4f4c6-ba52-422b-bb2d-4154135e8feb", "name": "", "x": 38.64306413997204, "y": -122.47091308420728, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0b645969-9136-42a9-b5ac-7d2f1ff71959", "name": "p1rlv17336", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bda4f4c6-ba52-422b-bb2d-4154135e8feb"}}}}, {"uuid": "cea73a9b-9f97-4242-820d-0a18752b434b", "name": "", "x": 38.643206712841376, "y": -122.47055581957126, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7af262b7-285c-4d06-b7ff-2f2a1971055a", "name": "p1rlv20492", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cea73a9b-9f97-4242-820d-0a18752b434b"}}}}, {"uuid": "dcb6e9c3-b78b-427f-835d-56f4c83eb710", "name": "", "x": 38.64331796921429, "y": -122.47124445290501, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6112cc26-bc37-4c72-8ef6-cd88f1296693", "name": "p1rdm17908", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dcb6e9c3-b78b-427f-835d-56f4c83eb710"}}}}, {"uuid": "0b5adf50-29df-4ada-9ca9-a7c149090ecb", "name": "", "x": 38.64340709749659, "y": -122.47102547122093, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8934db59-0c39-4838-9f8c-59a563cd9d54", "name": "p1rlv20455", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0b5adf50-29df-4ada-9ca9-a7c149090ecb"}}}}, {"uuid": "4410ab61-f4d7-4686-b7a5-9283f71a955f", "name": "", "x": 38.647797936596966, "y": -122.46665816549304, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "232fed6b-fe0f-4a44-93e9-e6675b50c39c", "name": "p1rdt8160lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4410ab61-f4d7-4686-b7a5-9283f71a955f"}}}}, {"uuid": "6ba1a4ef-2877-4400-a039-d27b9912e1d2", "name": "", "x": 38.64781228772558, "y": -122.4667089672996, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d5d7049e-9d30-474c-9033-3ad9b4487f7a", "name": "p1rlv17337", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6ba1a4ef-2877-4400-a039-d27b9912e1d2"}}}}, {"uuid": "a8334a25-2ec8-45e1-90a0-56ac56a0edc3", "name": "", "x": 38.644602062665655, "y": -122.47222549352858, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ac7e489e-7249-4702-9ed6-131cad34500f", "name": "p1rdt8161lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8334a25-2ec8-45e1-90a0-56ac56a0edc3"}}}}, {"uuid": "14ba7656-3e7a-48eb-84c9-cff77db459fd", "name": "", "x": 38.644748791082094, "y": -122.47278523601162, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "331389ab-5d04-4648-83b4-3043198c774f", "name": "p1rlv17338", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "14ba7656-3e7a-48eb-84c9-cff77db459fd"}}}}, {"uuid": "0680cc6e-da56-4ac2-b868-8618f91b4a6a", "name": "", "x": 38.617206962751396, "y": -122.42934627658663, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9560197a-21d1-4601-8bcb-213df4844f4a", "name": "p1rdt8346lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0680cc6e-da56-4ac2-b868-8618f91b4a6a"}}}}, {"uuid": "87600d73-a33f-43c6-92ff-0cbccc7eef41", "name": "", "x": 38.61718096900156, "y": -122.4293036828715, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7acb4e7d-cb06-4848-952d-7c68bb34b6db", "name": "p1rlv17702", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "87600d73-a33f-43c6-92ff-0cbccc7eef41"}}}}, {"uuid": "d12a0724-e31b-404e-8bac-0c3f130fa7e6", "name": "", "x": 38.61731941811156, "y": -122.46431093057339, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "408d5d7b-fc71-46bb-8de0-2d4e628c29b6", "name": "p1rdt8405lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d12a0724-e31b-404e-8bac-0c3f130fa7e6"}}}}, {"uuid": "59b1e009-bbd6-4229-8a8f-0ffc8ba2fd39", "name": "", "x": 38.61734493344011, "y": -122.46426786943886, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a52db2ff-b782-40c1-828a-c65f6929b2fc", "name": "p1rlv17781", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59b1e009-bbd6-4229-8a8f-0ffc8ba2fd39"}}}}, {"uuid": "4baa2cfd-b95d-4843-9f15-6446ca83fe8b", "name": "", "x": 38.62043416913732, "y": -122.45626485935486, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3fe0f77-a7c1-48e3-94aa-30b69f20ca65", "name": "p1rdt8408lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4baa2cfd-b95d-4843-9f15-6446ca83fe8b"}}}}, {"uuid": "1eae8901-0307-473a-a766-33150cf5b60b", "name": "", "x": 38.62067425594847, "y": -122.4561786638706, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9c9c1d9f-eeff-454f-b3d0-7e7de837694c", "name": "p1rlv17787", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1eae8901-0307-473a-a766-33150cf5b60b"}}}}, {"uuid": "bab9d82d-9b34-48ac-b25c-565c4824842b", "name": "", "x": 38.62014326917501, "y": -122.45633200676872, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b40fac8c-a99b-4baa-940a-26565ba7d62b", "name": "p1rlv18044", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bab9d82d-9b34-48ac-b25c-565c4824842b"}}}}, {"uuid": "c80213c4-13ed-4f25-a3db-f0e44ee86016", "name": "", "x": 38.62377947083559, "y": -122.45617863919693, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fca92353-c013-4c41-8507-ec8704410834", "name": "p1rdt8414lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c80213c4-13ed-4f25-a3db-f0e44ee86016"}}}}, {"uuid": "3bbdb11f-382f-4722-98b6-18945dc957b4", "name": "", "x": 38.623816236226766, "y": -122.4555001331194, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d9dba02d-086c-4906-9c6f-86532e3384c0", "name": "p1rlv17798", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3bbdb11f-382f-4722-98b6-18945dc957b4"}}}}, {"uuid": "f094ddcf-5d31-4a5f-853f-8314aa17aa7b", "name": "", "x": 38.59895000377746, "y": -122.46337821887984, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cfe35c35-8164-4825-81e3-10a2ece2cb27", "name": "p1rdt8422lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f094ddcf-5d31-4a5f-853f-8314aa17aa7b"}}}}, {"uuid": "0036a891-6aaf-4b34-8cf0-810e4e8d6bf0", "name": "", "x": 38.59842227673629, "y": -122.46362727672292, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3887a879-0783-4703-8a24-32b7e3b4f39d", "name": "p1rlv17810", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0036a891-6aaf-4b34-8cf0-810e4e8d6bf0"}}}}, {"uuid": "b81a4b3e-aeac-4baf-bc74-00bc42937f30", "name": "", "x": 38.59798139328054, "y": -122.46377984508203, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6f7776e4-a81f-48d2-b3c0-d70bfa48164e", "name": "p1rlv17847", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b81a4b3e-aeac-4baf-bc74-00bc42937f30"}}}}, {"uuid": "6e44a3e6-b8a2-4262-8184-2c558056127d", "name": "", "x": 38.598224600790864, "y": -122.46375506824658, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75e55237-b847-4fb7-a141-a0771bd868c6", "name": "p1rlv17876", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6e44a3e6-b8a2-4262-8184-2c558056127d"}}}}, {"uuid": "3e55eaf4-6618-482f-b4e3-c232453615b3", "name": "", "x": 38.59902589482566, "y": -122.46358833294255, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a7421f5c-bf5c-4d01-aa14-ba657f242080", "name": "p1rdm18545", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e55eaf4-6618-482f-b4e3-c232453615b3"}}}}, {"uuid": "e8a52517-868f-4231-8bad-cc741df29cce", "name": "", "x": 38.598360195447086, "y": -122.46384592887894, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2716887e-1701-4a78-805b-96da0781c7f8", "name": "p1rlv17961", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e8a52517-868f-4231-8bad-cc741df29cce"}}}}, {"uuid": "0ddbc6a9-40f9-4e00-a77f-e50a854446b3", "name": "", "x": 38.597552657762314, "y": -122.45740568785139, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cdc5ef2a-c0d0-4702-b6c6-df08af1e8746", "name": "p1rdt8434lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0ddbc6a9-40f9-4e00-a77f-e50a854446b3"}}}}, {"uuid": "c280eb31-f020-492f-8511-02bbf631c40b", "name": "", "x": 38.59741052481255, "y": -122.45723847553955, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0827675c-2467-403d-822e-5f74cd6296c5", "name": "p1rlv17857", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c280eb31-f020-492f-8511-02bbf631c40b"}}}}, {"uuid": "e0797818-9133-4fd4-93f8-5ecdb12592b1", "name": "", "x": 38.59577787216432, "y": -122.45996961185554, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b24c9345-625f-499d-96cf-30b2de5839b6", "name": "p1rdt8436lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e0797818-9133-4fd4-93f8-5ecdb12592b1"}}}}, {"uuid": "6b2266b6-8a5f-4e6d-8b4b-b4d91bf314c5", "name": "", "x": 38.59575188947818, "y": -122.45992701953358, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f44b0293-61e5-4054-b2d7-4a113df92b3c", "name": "p1rlv17877", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6b2266b6-8a5f-4e6d-8b4b-b4d91bf314c5"}}}}, {"uuid": "235a5cab-5833-447d-938d-8458cbfe5858", "name": "", "x": 38.61790022449083, "y": -122.4571375571412, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a38f544-e250-4fc9-942c-946c5cde0a33", "name": "p1rdt8439lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "235a5cab-5833-447d-938d-8458cbfe5858"}}}}, {"uuid": "ae72de9d-225e-480d-9e53-9d298035cd06", "name": "", "x": 38.61807504073576, "y": -122.45730102691826, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3f74f217-4765-406d-9646-d8f46377ef0a", "name": "p1rlv17897", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ae72de9d-225e-480d-9e53-9d298035cd06"}}}}, {"uuid": "d1f565f4-1b19-4624-acab-6843789b0f04", "name": "", "x": 38.597579593964674, "y": -122.45871858209406, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c6460e5c-839d-4f9e-b9d6-b187fddb9ab6", "name": "p1rdm18631", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1f565f4-1b19-4624-acab-6843789b0f04"}}}}, {"uuid": "e30f89b8-4654-434d-a298-685c0c334130", "name": "", "x": 38.59739305808095, "y": -122.45930564328731, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ab733d49-bb36-4631-8824-1967f98f758a", "name": "p1rlv17909", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e30f89b8-4654-434d-a298-685c0c334130"}}}}, {"uuid": "b0e348c6-668d-45f5-89d6-80130a49de58", "name": "", "x": 38.59774507812581, "y": -122.45881317872153, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "049362b4-49de-4e80-921e-ff763aaab2d1", "name": "p1rdt8440lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b0e348c6-668d-45f5-89d6-80130a49de58"}}}}, {"uuid": "6eb673d0-753b-41b4-9d72-6e3b93827970", "name": "", "x": 38.59785985557703, "y": -122.45891169861048, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7633fe6b-a48b-4e7d-90e6-a38b8a861936", "name": "p1rdm18632", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6eb673d0-753b-41b4-9d72-6e3b93827970"}}}}, {"uuid": "7b013b37-85eb-43c0-8866-e81aa9d95460", "name": "", "x": 38.59783092542888, "y": -122.45911464995726, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1ccaf70a-35d8-4f16-b632-e282fe30b5ca", "name": "p1rlv17969", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7b013b37-85eb-43c0-8866-e81aa9d95460"}}}}, {"uuid": "50b1484b-4818-4428-9e9a-3bde30411fd7", "name": "", "x": 38.592426036395636, "y": -122.46351864990689, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "72c8f08a-0ba5-413e-a805-f9436b41ff29", "name": "p1rdt8441lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "50b1484b-4818-4428-9e9a-3bde30411fd7"}}}}, {"uuid": "a04c8189-e692-459c-a5f1-48dde6ab4744", "name": "", "x": 38.59244738401374, "y": -122.46362580620794, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3eb66d3-0271-4842-8893-9a58f64e0279", "name": "p1rlv17912", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a04c8189-e692-459c-a5f1-48dde6ab4744"}}}}, {"uuid": "8a776ad0-780d-4247-ade1-f5cf9ea31a4b", "name": "", "x": 38.597607065823205, "y": -122.46357324186411, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6b5ae28a-95f8-4023-aa23-36809fe96b10", "name": "p1rdt8442lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8a776ad0-780d-4247-ade1-f5cf9ea31a4b"}}}}, {"uuid": "b197b384-d376-4d94-876a-0a809b11da97", "name": "", "x": 38.597593266344134, "y": -122.46362425623258, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2812bbb1-0bb0-499f-a394-0995784bb7bc", "name": "p1rlv17926", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b197b384-d376-4d94-876a-0a809b11da97"}}}}, {"uuid": "867451dd-75d8-47b5-bd21-ccfa0b329ea5", "name": "", "x": 38.59572176348798, "y": -122.45708645620138, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "978920e8-edf9-4bee-85f9-45f4081ed0ca", "name": "p1rdt8444lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "867451dd-75d8-47b5-bd21-ccfa0b329ea5"}}}}, {"uuid": "105845cf-c40d-4173-81fd-b74861397ce6", "name": "", "x": 38.59568814197167, "y": -122.45699881396531, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "215a5974-e23b-46f0-bde9-f5ad16fdfaf8", "name": "p1rlv17960", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "105845cf-c40d-4173-81fd-b74861397ce6"}}}}, {"uuid": "10f191de-e023-4808-85f5-012176f1336e", "name": "", "x": 38.595797079946, "y": -122.45717024246757, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "86917829-123c-4fda-9809-dc61430a9fef", "name": "p1rlv18071", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10f191de-e023-4808-85f5-012176f1336e"}}}}, {"uuid": "e52bb183-08e0-4285-8429-5d7606c19fe0", "name": "", "x": 38.61751627823996, "y": -122.46078567224485, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7e0923da-550b-479f-b3d8-3e0320db6701", "name": "p1rdt8445lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e52bb183-08e0-4285-8429-5d7606c19fe0"}}}}, {"uuid": "a8649d36-5197-4a25-b6b5-550f77429a73", "name": "", "x": 38.61713929235215, "y": -122.46152369067127, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ec99daac-e0be-4ea1-ba4f-185d4943396d", "name": "p1rlv17962", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8649d36-5197-4a25-b6b5-550f77429a73"}}}}, {"uuid": "664da3a5-5133-402f-8d86-f3c67ca71d77", "name": "", "x": 38.62155491914008, "y": -122.45674368662482, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5dbc3459-6a17-4075-899a-6aab16fb3ab7", "name": "p1rdt8447lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "664da3a5-5133-402f-8d86-f3c67ca71d77"}}}}, {"uuid": "98a16178-ae9b-49b9-9dba-5f7325d4f142", "name": "", "x": 38.6215289352912, "y": -122.45670108034808, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0771ebfa-5eaf-4ae8-94f1-86de7a656f58", "name": "p1rlv17987", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "98a16178-ae9b-49b9-9dba-5f7325d4f142"}}}}, {"uuid": "605fd3a1-c920-45b2-ad64-ca60322bc1c0", "name": "", "x": 38.59745455680166, "y": -122.45591485249561, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8b4216c8-9e99-446c-ad09-5a09f046dd59", "name": "p1rdt8450lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "605fd3a1-c920-45b2-ad64-ca60322bc1c0"}}}}, {"uuid": "f8e8c7c1-26b6-495f-9e34-86907f86c0ad", "name": "", "x": 38.597480069191974, "y": -122.45587180037909, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4aeda1c7-41be-43c8-82e5-d7a347db86a8", "name": "p1rlv18053", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f8e8c7c1-26b6-495f-9e34-86907f86c0ad"}}}}, {"uuid": "ac621d29-9618-4700-9b16-28e6618b6676", "name": "", "x": 38.623331409033426, "y": -122.45649925442898, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d094b779-ebcc-4837-9ccb-31808e2a544b", "name": "p1rdt8456lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ac621d29-9618-4700-9b16-28e6618b6676"}}}}, {"uuid": "722dda28-849d-4e17-a584-550e06ef2a68", "name": "", "x": 38.62321497484187, "y": -122.45604459936547, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c4863d28-4ee2-479d-accb-60b54f472fe7", "name": "p1rlv18100", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "722dda28-849d-4e17-a584-550e06ef2a68"}}}}, {"uuid": "dc23a352-01e5-4e67-9210-bb6fbafba6c4", "name": "", "x": 38.62104504107823, "y": -122.4556217772947, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e597d8da-e876-44a5-a109-1ce84527c557", "name": "p1rdt8458lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dc23a352-01e5-4e67-9210-bb6fbafba6c4"}}}}, {"uuid": "f36410e9-465d-44f3-8ab5-6e0fd2624084", "name": "", "x": 38.62101905682373, "y": -122.45557917172717, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "115a848f-f6f3-48f0-9f33-5a9103f1a892", "name": "p1rlv18129", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f36410e9-465d-44f3-8ab5-6e0fd2624084"}}}}, {"uuid": "804f0048-b140-4280-ba5b-87306c6feacc", "name": "", "x": 38.6478890270985, "y": -122.44178196559784, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "edb15d92-f98a-4fa2-8129-ad8a39e0dc0c", "name": "p1rdt8470lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "804f0048-b140-4280-ba5b-87306c6feacc"}}}}, {"uuid": "4ba6adc1-6162-4155-a2bd-22b86bf1188e", "name": "", "x": 38.6478781196749, "y": -122.4418348710007, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "431692e5-2917-41ea-aafc-96be180b7e27", "name": "p1rlv18166", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ba6adc1-6162-4155-a2bd-22b86bf1188e"}}}}, {"uuid": "b73e98fa-cf90-4060-8e49-9e9faf47c7fb", "name": "", "x": 38.59296538348102, "y": -122.52138816471086, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a84e1424-7faf-4077-9461-b39460f10ef0", "name": "p1rdt8490lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b73e98fa-cf90-4060-8e49-9e9faf47c7fb"}}}}, {"uuid": "ed117aae-82ac-4c66-942a-b71b10ab7463", "name": "", "x": 38.59301371324328, "y": -122.5214951600568, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1c3e08a8-ea88-423d-b361-69509f7ab8fa", "name": "p1rlv18192", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ed117aae-82ac-4c66-942a-b71b10ab7463"}}}}, {"uuid": "5ebb3cfc-a5b0-49a9-a24f-877580473c4b", "name": "", "x": 38.59294983327106, "y": -122.521300375614, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5a7cb078-af6c-4cd5-9aca-48f515f6e711", "name": "p1rlv18198", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ebb3cfc-a5b0-49a9-a24f-877580473c4b"}}}}, {"uuid": "de057e16-abb7-41f6-af51-aebbadc2b25b", "name": "", "x": 38.59325808671421, "y": -122.5203178073169, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "127e4cc7-6413-4482-9ec3-40f8bde02d0c", "name": "p1rdt8492lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "de057e16-abb7-41f6-af51-aebbadc2b25b"}}}}, {"uuid": "ef8d5eb6-940c-46a1-831a-9669016160a2", "name": "", "x": 38.59327241449537, "y": -122.5203685817209, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c5e240e8-b27d-4181-a7ee-a004d3f5c58a", "name": "p1rlv18197", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef8d5eb6-940c-46a1-831a-9669016160a2"}}}}, {"uuid": "a61ec7ca-3ace-4736-9144-904c04e0c148", "name": "", "x": 38.60984174522787, "y": -122.47657385883775, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "95a1a7c7-6055-47c9-a742-c1b81f6c7478", "name": "p1rdt8802lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a61ec7ca-3ace-4736-9144-904c04e0c148"}}}}, {"uuid": "a6e85fe6-c716-4a0f-a8c2-0f24fd3a2386", "name": "", "x": 38.609856091968865, "y": -122.47662463597939, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9178fdee-311f-40f5-bdd6-9b474a05247e", "name": "p1rlv18960", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a6e85fe6-c716-4a0f-a8c2-0f24fd3a2386"}}}}, {"uuid": "2f141231-7a01-4055-8435-d27aaab6e5a0", "name": "", "x": 38.60811019336638, "y": -122.4764535430088, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "715c92fa-2470-4869-8d5f-0b4f3f8360d4", "name": "p1rdt8805lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2f141231-7a01-4055-8435-d27aaab6e5a0"}}}}, {"uuid": "8dee19e0-8f93-421c-89dc-21a73c4b7405", "name": "", "x": 38.60841504125986, "y": -122.4772548473748, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eef4f0cf-6e51-45e1-8b6e-84171f7cbef6", "name": "p1rlv18967", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8dee19e0-8f93-421c-89dc-21a73c4b7405"}}}}, {"uuid": "44c9f757-2bb1-4fa1-b546-bd34b4b7f2f9", "name": "", "x": 38.581410942364535, "y": -122.50908841868979, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f6ff626c-d2fc-4b97-9013-4fd544d946a2", "name": "p1rdt8898lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "44c9f757-2bb1-4fa1-b546-bd34b4b7f2f9"}}}}, {"uuid": "57fd1592-5243-4363-8282-086d2487b045", "name": "", "x": 38.58102797028686, "y": -122.50847493360112, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2cf28b5d-d8d4-4883-a396-2d1ad9b70564", "name": "p1rlv19157", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "57fd1592-5243-4363-8282-086d2487b045"}}}}, {"uuid": "f3f75cf1-080c-47d4-977e-453e2b885282", "name": "", "x": 38.58165154784808, "y": -122.50878549370569, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "09d59048-6e1b-4f7f-b161-81163809eb25", "name": "p1rdm19752", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f3f75cf1-080c-47d4-977e-453e2b885282"}}}}, {"uuid": "e8ccc470-71ba-4c98-aee7-701cc49838f9", "name": "", "x": 38.581235479806075, "y": -122.50853092416536, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "67a4600d-65c3-40d7-ad28-e8e37ff77dcb", "name": "p1rlv19149", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e8ccc470-71ba-4c98-aee7-701cc49838f9"}}}}, {"uuid": "b56887ea-0407-49d2-a1d7-9cbc77058ca0", "name": "", "x": 38.581243768243056, "y": -122.5083586529402, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c7c1d210-ee87-46c5-b408-ad221cbeed04", "name": "p1rlv19160", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b56887ea-0407-49d2-a1d7-9cbc77058ca0"}}}}, {"uuid": "240e4997-1186-4c77-b45b-065a2ebd972c", "name": "", "x": 38.58115574730252, "y": -122.50928817819602, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a7664d29-bbc0-4465-a00a-82af048b86e5", "name": "p1rdm19755", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "240e4997-1186-4c77-b45b-065a2ebd972c"}}}}, {"uuid": "2d04d1e5-eafb-4f34-b561-44619bce9aa4", "name": "", "x": 38.58064928716368, "y": -122.50843159103809, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "994f6392-f4e5-4ff8-9eeb-5849cd035912", "name": "p1rlv19166", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2d04d1e5-eafb-4f34-b561-44619bce9aa4"}}}}, {"uuid": "e8c464bc-8647-472f-ae74-067475e1724b", "name": "", "x": 38.58121826088946, "y": -122.50725268309377, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d53c0a2-78cc-4988-85a4-884ef039f5fa", "name": "p1rdt8901lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e8c464bc-8647-472f-ae74-067475e1724b"}}}}, {"uuid": "11091ed9-9278-418b-a4b8-3759b0797ce7", "name": "", "x": 38.58123620687723, "y": -122.50802972585609, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16df6b90-d049-4160-b148-b888e03acb82", "name": "p1rlv19161", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "11091ed9-9278-418b-a4b8-3759b0797ce7"}}}}, {"uuid": "064e0b49-6ead-4a53-af44-38565a7e6781", "name": "", "x": 38.65991234943945, "y": -122.43854233081237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e111e213-bcbe-42c4-b6ab-2c734ff5341c", "name": "p1rdt8904lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "064e0b49-6ead-4a53-af44-38565a7e6781"}}}}, {"uuid": "40047848-7a14-4001-aecf-88ae0011c629", "name": "", "x": 38.660223463841156, "y": -122.43823709517063, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1f8c76ca-40ea-4f7d-8042-66edd484f065", "name": "p1rlv19168", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "40047848-7a14-4001-aecf-88ae0011c629"}}}}, {"uuid": "f8047d0f-fd7f-4cd1-a199-62ef50463692", "name": "", "x": 38.659990269866015, "y": -122.43846878718209, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e0fc7d43-4f82-4100-99bf-6e30e03e95ce", "name": "p1rlv19174", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f8047d0f-fd7f-4cd1-a199-62ef50463692"}}}}, {"uuid": "184974a9-5002-4bab-bace-c579e696241d", "name": "", "x": 38.659792348994905, "y": -122.43853929357995, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8b9386f2-376d-4439-a9a4-3eefc238dafe", "name": "p1rdm19776", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "184974a9-5002-4bab-bace-c579e696241d"}}}}, {"uuid": "97d3a98b-859b-4c49-9814-8854ec2c9ea8", "name": "", "x": 38.659815187445474, "y": -122.43766561018224, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "50750ddb-80db-4d5f-bc62-4bbfc600a7ef", "name": "p1rlv19184", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "97d3a98b-859b-4c49-9814-8854ec2c9ea8"}}}}, {"uuid": "6760425d-5a9c-4a69-a620-335a6a50dd5a", "name": "", "x": 38.66094193321756, "y": -122.4420778873007, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be2777cc-f3fd-491f-a10b-4ed381cb948d", "name": "p1rdt8905lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6760425d-5a9c-4a69-a620-335a6a50dd5a"}}}}, {"uuid": "e4fb0dbb-9f87-44eb-8fc2-c6fa5b3b190c", "name": "", "x": 38.66079928545388, "y": -122.4418071207425, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be4e8183-9148-477e-aa1b-ff31a5324273", "name": "p1rlv19169", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e4fb0dbb-9f87-44eb-8fc2-c6fa5b3b190c"}}}}, {"uuid": "cdebdf2f-ce8a-4206-9a08-febb53cf2595", "name": "", "x": 38.66134282316126, "y": -122.44240057565185, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fffe26f7-c4cc-420e-ab17-754cb0d9e659", "name": "p1rlv19171", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cdebdf2f-ce8a-4206-9a08-febb53cf2595"}}}}, {"uuid": "a3f6aa7b-1b7e-4b4c-99f6-ba8b0c163e86", "name": "", "x": 38.661324142709425, "y": -122.44226279573506, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "21fec301-b67c-4042-a074-caf406c7f0b5", "name": "p1rlv19173", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a3f6aa7b-1b7e-4b4c-99f6-ba8b0c163e86"}}}}, {"uuid": "e1a509d5-5978-458c-b5a3-4a6ad7aa48bb", "name": "", "x": 38.660891099685436, "y": -122.44216271154556, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "47e24942-486d-46f1-a40f-0da5c93c013a", "name": "p1rlv19188", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e1a509d5-5978-458c-b5a3-4a6ad7aa48bb"}}}}, {"uuid": "8daf8c62-fb93-452e-a50f-f20fd4575028", "name": "", "x": 38.660438772467124, "y": -122.44179842559906, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d7daa1d3-6249-447d-a260-65de5ec0a470", "name": "p1rlv19194", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8daf8c62-fb93-452e-a50f-f20fd4575028"}}}}, {"uuid": "f5014d04-b09d-4eb3-ab03-0922624e3ed6", "name": "", "x": 38.65966647434038, "y": -122.44177391418427, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c306f79a-0240-465e-a486-d0f11614fc57", "name": "p1rdt8911lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5014d04-b09d-4eb3-ab03-0922624e3ed6"}}}}, {"uuid": "ef46d329-2e90-4650-bdbe-4d60014873d6", "name": "", "x": 38.659762694003604, "y": -122.44175769963816, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "89bde057-807b-415c-9135-267c6bf43c44", "name": "p1rlv19183", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef46d329-2e90-4650-bdbe-4d60014873d6"}}}}, {"uuid": "f91d9e6c-5898-4087-987a-3ebafb3c94ca", "name": "", "x": 38.659528505871954, "y": -122.44178250448644, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4a8ae6dc-884d-48d8-9995-fe3936ad019c", "name": "p1rlv20296", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f91d9e6c-5898-4087-987a-3ebafb3c94ca"}}}}, {"uuid": "0edbaaa4-6519-455b-9246-8a1c2a9156ca", "name": "", "x": 38.66174426844995, "y": -122.44236029493588, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2fbbca23-6473-4344-ac2e-cc97078b3d8d", "name": "p1rdt8915lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0edbaaa4-6519-455b-9246-8a1c2a9156ca"}}}}, {"uuid": "6b82329d-8f91-4a11-af20-f5eea8feb9c7", "name": "", "x": 38.66176977524987, "y": -122.44231719933447, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5fecc64a-4783-4ecb-a0d0-7e60d1cf6184", "name": "p1rlv19189", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6b82329d-8f91-4a11-af20-f5eea8feb9c7"}}}}, {"uuid": "9b3f7497-3003-404d-b677-bcdb323c6ab4", "name": "", "x": 38.66022824513094, "y": -122.4403032002883, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d268e33-708d-4bae-8348-cad27fd0d81a", "name": "p1rdt8916lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9b3f7497-3003-404d-b677-bcdb323c6ab4"}}}}, {"uuid": "04b52ef4-71da-4abc-bfca-23d50fefdad0", "name": "", "x": 38.66024260770121, "y": -122.44035400544816, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4aee02d4-8663-455b-a197-55b6b1470895", "name": "p1rlv19190", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "04b52ef4-71da-4abc-bfca-23d50fefdad0"}}}}, {"uuid": "3a99f762-bf86-47c2-a9c5-ba32b79116be", "name": "", "x": 38.655203793367576, "y": -122.45620231524185, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6752e8f4-9e37-476d-aec2-4a2fe7c1e2dc", "name": "p1rdt9075lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3a99f762-bf86-47c2-a9c5-ba32b79116be"}}}}, {"uuid": "2f6f79fa-c192-4f73-8fe9-34244be1e20a", "name": "", "x": 38.65518999754597, "y": -122.45625337194336, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33dcb037-4cc8-480f-aac4-bc95e54e165e", "name": "p1rlv19667", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2f6f79fa-c192-4f73-8fe9-34244be1e20a"}}}}, {"uuid": "18e29a87-cfae-409d-a4d0-59cdfda79164", "name": "", "x": 38.659371136386014, "y": -122.45366040420096, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bdd64386-e256-47f8-8cef-1c933f993a29", "name": "p1rdt9076lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "18e29a87-cfae-409d-a4d0-59cdfda79164"}}}}, {"uuid": "510bb7b0-5542-41e1-85d9-ab5f40613641", "name": "", "x": 38.65966620569122, "y": -122.45316394323339, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "14b1ab4e-b22d-4a98-8131-fc72c923c735", "name": "p1rlv19698", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "510bb7b0-5542-41e1-85d9-ab5f40613641"}}}}, {"uuid": "12fed0c5-f799-4023-b80f-43c58a88eefd", "name": "", "x": 38.65923252263959, "y": -122.45353105574254, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fd00c91a-01a8-4aad-b740-b06a654d631b", "name": "p1rdm20204", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "12fed0c5-f799-4023-b80f-43c58a88eefd"}}}}, {"uuid": "6ba53ded-0201-4663-a8a2-5703783675ba", "name": "", "x": 38.65913430903858, "y": -122.45372718962375, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6427f66-2e22-40bb-83f1-2a8b1be9191a", "name": "p1rlv19668", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6ba53ded-0201-4663-a8a2-5703783675ba"}}}}, {"uuid": "7a201e5f-5a2b-4c99-866d-0b8445ce2f1e", "name": "", "x": 38.659402236788104, "y": -122.45320795008209, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48654a82-ac11-4542-94ec-8f731138e1a8", "name": "p1rlv19699", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7a201e5f-5a2b-4c99-866d-0b8445ce2f1e"}}}}, {"uuid": "3219c596-244a-4592-ac08-1498542b882a", "name": "", "x": 38.65946805558687, "y": -122.45379361501921, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ce8f50bb-90fb-49b8-8a16-1bbbb6a0c82c", "name": "p1rdm20205", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3219c596-244a-4592-ac08-1498542b882a"}}}}, {"uuid": "8c0543e4-bfd1-4ea1-abd8-9f20075a02f4", "name": "", "x": 38.65960231517979, "y": -122.45359720642892, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "47f5777d-2c8d-48c2-bf28-386f3f3dbac4", "name": "p1rlv19686", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8c0543e4-bfd1-4ea1-abd8-9f20075a02f4"}}}}, {"uuid": "61eb89b7-5c68-4fe6-a2cf-65b8a9334552", "name": "", "x": 38.652242872397366, "y": -122.46144885825713, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6b83eaaa-a092-42ca-a746-db4d9658d62b", "name": "p1rdt9077lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "61eb89b7-5c68-4fe6-a2cf-65b8a9334552"}}}}, {"uuid": "d2c378d1-16dd-475a-96e9-e684db274429", "name": "", "x": 38.65239205276167, "y": -122.4611909367415, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "96d3079a-02f1-4c89-ad75-fd0a438c9cf4", "name": "p1rlv19669", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d2c378d1-16dd-475a-96e9-e684db274429"}}}}, {"uuid": "955a59ba-ed77-4cb8-ba64-6835fb9101a6", "name": "", "x": 38.65223106297542, "y": -122.46145646522658, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0031ab1b-d82d-40a5-b41e-bc6f6cb53069", "name": "p1rlv19675", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "955a59ba-ed77-4cb8-ba64-6835fb9101a6"}}}}, {"uuid": "54b6622c-d1f3-4f49-9fe9-b34c2b16e965", "name": "", "x": 38.65203392082483, "y": -122.46169927854602, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35fe21a1-f817-426e-9e42-f1f33876dd7d", "name": "p1rlv19695", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "54b6622c-d1f3-4f49-9fe9-b34c2b16e965"}}}}, {"uuid": "52222e5e-929d-40e5-9033-af986edf0e1c", "name": "", "x": 38.658511634388226, "y": -122.45377906068661, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7f0e4f59-8a46-4abf-9f06-e0383a59a45d", "name": "p1rdt9084lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "52222e5e-929d-40e5-9033-af986edf0e1c"}}}}, {"uuid": "7d2fecb9-f2e2-4813-bc4a-f2dd44b73ae1", "name": "", "x": 38.65890081567661, "y": -122.4539013635132, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "83afc678-d577-4ef1-afa2-8e3f915a158b", "name": "p1rlv19681", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7d2fecb9-f2e2-4813-bc4a-f2dd44b73ae1"}}}}, {"uuid": "87d5d0d0-3503-4fb3-90d4-b7010024e8e1", "name": "", "x": 38.65082653264708, "y": -122.46112619224643, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "565bbfb1-a28f-4db2-be48-cbd58972025a", "name": "p1rdt9085lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "87d5d0d0-3503-4fb3-90d4-b7010024e8e1"}}}}, {"uuid": "024c67e1-26f2-4e2d-a9e1-2363314f620e", "name": "", "x": 38.65123799892708, "y": -122.46107316768796, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "811acd48-b61c-4a42-b76e-f995961c450e", "name": "p1rlv19682", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "024c67e1-26f2-4e2d-a9e1-2363314f620e"}}}}, {"uuid": "e9eeb7a0-71f8-42f2-8fde-92047b07a318", "name": "", "x": 38.650795641302004, "y": -122.46090410093127, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ec27727b-2bb8-4df2-9ddf-46282728c2c0", "name": "p1rdm20223", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e9eeb7a0-71f8-42f2-8fde-92047b07a318"}}}}, {"uuid": "0e0f0e38-cf93-421d-b57f-3480c11f4488", "name": "", "x": 38.65132742554806, "y": -122.46092309986851, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1b5d936f-b3e0-408e-aabd-d3ebb7b869b0", "name": "p1rlv19701", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0e0f0e38-cf93-421d-b57f-3480c11f4488"}}}}, {"uuid": "f408d815-1e53-4979-87cd-e7df5fb7d70f", "name": "", "x": 38.65246361026913, "y": -122.46218753579743, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f8108ac8-2807-4a40-85c2-db21efaadadb", "name": "p1rdt9089lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f408d815-1e53-4979-87cd-e7df5fb7d70f"}}}}, {"uuid": "35ae0831-567f-4d28-ba9e-19a634226d71", "name": "", "x": 38.65247796334516, "y": -122.46223833997352, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "578b5df8-1dd8-41d9-b6dc-db75db5b115e", "name": "p1rlv19689", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "35ae0831-567f-4d28-ba9e-19a634226d71"}}}}, {"uuid": "7fb01aed-5f5d-4a4a-8919-592230ce46fe", "name": "", "x": 38.65140101826137, "y": -122.46336158947928, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6fc84159-09b1-4ca9-9a7a-a4fecab19f83", "name": "p1rdt9090lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7fb01aed-5f5d-4a4a-8919-592230ce46fe"}}}}, {"uuid": "67c1af07-75b2-4ed0-80c3-3d37cc36508d", "name": "", "x": 38.651714420003884, "y": -122.4627704444441, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e2709a70-1a7d-454c-90fd-377e416a0071", "name": "p1rlv19690", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "67c1af07-75b2-4ed0-80c3-3d37cc36508d"}}}}, {"uuid": "b8912d59-aeda-43db-8f27-552d50bb9d26", "name": "", "x": 38.650846513531, "y": -122.46155124895908, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1e93ea18-150d-4d80-bac7-f3e1b87c5b4e", "name": "p1rdt9091lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b8912d59-aeda-43db-8f27-552d50bb9d26"}}}}, {"uuid": "ff33634d-a59f-408c-ac9f-96661327410f", "name": "", "x": 38.65126752046812, "y": -122.4616130767133, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b10b272a-2efb-4e19-9921-d4081fb45778", "name": "p1rlv19692", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ff33634d-a59f-408c-ac9f-96661327410f"}}}}, {"uuid": "43134dcc-0533-4dab-bdbd-171362ac4a36", "name": "", "x": 38.65985495091543, "y": -122.45426942925806, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2f0726b7-3050-4c78-9c06-b9fd0c863ff3", "name": "p1rdt9093lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "43134dcc-0533-4dab-bdbd-171362ac4a36"}}}}, {"uuid": "80050a7c-ddcb-47cd-bd59-7f16d2859412", "name": "", "x": 38.65961615387016, "y": -122.45463151295169, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "37f72c85-61f7-4a42-94b0-6a627195458c", "name": "p1rlv19702", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "80050a7c-ddcb-47cd-bd59-7f16d2859412"}}}}, {"uuid": "f4631a44-4de8-418b-94ae-9e7331f02e3b", "name": "", "x": 38.629339299867084, "y": -122.45270506395599, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1c01a9b2-b002-4279-905e-950452f64f32", "name": "p1rdt9264lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f4631a44-4de8-418b-94ae-9e7331f02e3b"}}}}, {"uuid": "27ed1f16-03eb-42ce-8702-a73fa474132f", "name": "", "x": 38.629416853696135, "y": -122.45255114958653, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aaea76fa-797e-46c5-a70f-a973977db841", "name": "p1rlv20064", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "27ed1f16-03eb-42ce-8702-a73fa474132f"}}}}, {"uuid": "881403a8-f760-42b5-8e71-49adf089ec98", "name": "", "x": 38.629219943787845, "y": -122.4528398621658, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ea48ffa1-bdb3-4c15-96c9-ff7d7f34824f", "name": "p1rlv20065", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "881403a8-f760-42b5-8e71-49adf089ec98"}}}}, {"uuid": "b4544aa4-b735-4c64-84e5-139bf0f516a2", "name": "", "x": 38.62682787398021, "y": -122.443538396124, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "77d62813-61d3-4afd-9f21-869e2ea23e17", "name": "p1rdt9265lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b4544aa4-b735-4c64-84e5-139bf0f516a2"}}}}, {"uuid": "d260b95e-211c-4042-a884-17ace9831ea6", "name": "", "x": 38.626801885358226, "y": -122.44349579157367, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f450eeb4-3d87-4ae5-a6d6-958d7efd2712", "name": "p1rlv20066", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d260b95e-211c-4042-a884-17ace9831ea6"}}}}, {"uuid": "88a974e9-a865-4c00-8ffc-1e39aa989a25", "name": "", "x": 38.63354009061449, "y": -122.4470022329432, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "78278589-be2d-4d99-9c03-92c221348917", "name": "p1rdt9266lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "88a974e9-a865-4c00-8ffc-1e39aa989a25"}}}}, {"uuid": "0c7edbb5-8c60-4dd4-8097-98444bf41092", "name": "", "x": 38.6335544502105, "y": -122.44705302069676, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "66a710fb-26c7-4465-b7ea-43ec107008dc", "name": "p1rlv20067", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0c7edbb5-8c60-4dd4-8097-98444bf41092"}}}}, {"uuid": "59e72f91-e9dd-4f26-9cdd-f72aaafbf0b6", "name": "", "x": 38.57668432917656, "y": -122.5244581272183, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "208f222c-45db-445f-ba0b-a4a195ca68a6", "name": "p1rdt9298lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59e72f91-e9dd-4f26-9cdd-f72aaafbf0b6"}}}}, {"uuid": "af9dc8ee-cee4-460f-9c97-b2613c61e390", "name": "", "x": 38.57703900731173, "y": -122.52455160092381, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ffc82be6-f3f8-4a68-b6e6-da60b137329c", "name": "p1rlv20130", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "af9dc8ee-cee4-460f-9c97-b2613c61e390"}}}}, {"uuid": "4d3a48b7-fd17-4c40-ad5a-1107322e7fa2", "name": "", "x": 38.57648055489435, "y": -122.52532048800711, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "180fad26-0e7d-4e2c-ba17-c8e3315ca278", "name": "p1rdt9302lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d3a48b7-fd17-4c40-ad5a-1107322e7fa2"}}}}, {"uuid": "55752a53-a905-418a-94b6-4741fc94dd93", "name": "", "x": 38.57700673397096, "y": -122.52548171913072, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d635a151-2d13-47e9-8043-a214415a5b5e", "name": "p1rlv20138", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "55752a53-a905-418a-94b6-4741fc94dd93"}}}}, {"uuid": "6be69bf2-e2da-4ffd-8e12-9ecb59720f76", "name": "", "x": 38.57718617464166, "y": -122.52237333536553, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d4940a0e-dcc2-45fb-baa9-aadc84f8e882", "name": "p1rdt9310lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6be69bf2-e2da-4ffd-8e12-9ecb59720f76"}}}}, {"uuid": "ab4905b9-4e99-49bb-a83d-8bfaa642964a", "name": "", "x": 38.576705284221035, "y": -122.5222692278727, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9d615e93-a289-41ec-bda0-3b72bf15677e", "name": "p1rlv20146", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ab4905b9-4e99-49bb-a83d-8bfaa642964a"}}}}, {"uuid": "95a5439a-0a5c-4f7b-ae08-bed7b34b0ecf", "name": "", "x": 38.57637456989155, "y": -122.51922519254137, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b9e0aa7d-9097-4370-8f5e-52a5885da85c", "name": "p1rdt9311lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "95a5439a-0a5c-4f7b-ae08-bed7b34b0ecf"}}}}, {"uuid": "85a764e0-e69e-45dc-8957-3b9ca0ab1fd3", "name": "", "x": 38.576279327246795, "y": -122.51948236126216, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16b2add7-6a6d-4359-ad6f-f60edf435a4c", "name": "p1rlv20147", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "85a764e0-e69e-45dc-8957-3b9ca0ab1fd3"}}}}, {"uuid": "88a233ee-71b3-424d-a3b1-cf5eb54ab2a0", "name": "", "x": 38.57622563406502, "y": -122.51957456046857, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e938635b-e0d2-4e1b-a312-5a8f51e1dd7a", "name": "p1rlv20163", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "88a233ee-71b3-424d-a3b1-cf5eb54ab2a0"}}}}, {"uuid": "252394b9-5e80-462d-b1ad-93684148d1b5", "name": "", "x": 38.57944374835563, "y": -122.52129067940982, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0a21f5ca-51ef-4f81-8229-163182f011cf", "name": "p1rdt9312lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "252394b9-5e80-462d-b1ad-93684148d1b5"}}}}, {"uuid": "f1070023-ce6c-4a46-a28b-44adc0b27a78", "name": "", "x": 38.579207205820964, "y": -122.52143752839837, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a4a0c2f2-f75e-4c9c-b3f7-d8d9ada9cb82", "name": "p1rlv20148", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f1070023-ce6c-4a46-a28b-44adc0b27a78"}}}}, {"uuid": "0c82b69e-699d-4e19-95a1-17d14b7c7c9b", "name": "", "x": 38.57963859321071, "y": -122.52114764756729, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "27dfea92-734e-49d3-b245-dc933df66889", "name": "p1rlv20160", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0c82b69e-699d-4e19-95a1-17d14b7c7c9b"}}}}, {"uuid": "aa912d24-a8bb-448b-a77f-ee94b50f811c", "name": "", "x": 38.57499954420577, "y": -122.51877161682458, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3df13d91-365e-411b-917d-b28df5989280", "name": "p1rdt9314lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aa912d24-a8bb-448b-a77f-ee94b50f811c"}}}}, {"uuid": "03254f1e-f392-4daf-802c-1b58ee985315", "name": "", "x": 38.57488526903181, "y": -122.5194726576567, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3eb214b9-827f-4995-a862-907be02b029d", "name": "p1rlv20473", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "03254f1e-f392-4daf-802c-1b58ee985315"}}}}, {"uuid": "99be95b3-5b0a-4a25-88ec-b2a960507eeb", "name": "", "x": 38.57479824917913, "y": -122.51872307044951, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d5930295-0e44-4498-ae22-7647b72c1fa1", "name": "p1rdm20686", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "99be95b3-5b0a-4a25-88ec-b2a960507eeb"}}}}, {"uuid": "fa40295b-b2bc-4dca-a1a5-18c69a4d7b10", "name": "", "x": 38.574765880638516, "y": -122.5196187229471, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "956f4975-7383-4e0b-9114-d333a6ec4005", "name": "p1rlv20151", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa40295b-b2bc-4dca-a1a5-18c69a4d7b10"}}}}, {"uuid": "842bddbc-e3f4-415c-9892-b5c663d506b7", "name": "", "x": 38.57481830117202, "y": -122.51921657510196, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a7a43aa6-2be8-4320-8089-57d388633c6b", "name": "p1rlv20456", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "842bddbc-e3f4-415c-9892-b5c663d506b7"}}}}, {"uuid": "b7d25399-f31a-4e49-adba-a78ff86c5b8b", "name": "", "x": 38.57661532605132, "y": -122.51941521089782, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8c97a99f-545b-49cd-b1fe-4fd9e04bf37f", "name": "p1rdt9316lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b7d25399-f31a-4e49-adba-a78ff86c5b8b"}}}}, {"uuid": "be71b6c1-afc0-467f-8b9b-c08c14272f70", "name": "", "x": 38.57645998524856, "y": -122.51958447974425, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ef20846d-d685-4c65-8dfb-bc23317501c5", "name": "p1rlv20153", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be71b6c1-afc0-467f-8b9b-c08c14272f70"}}}}, {"uuid": "2a99897f-364d-411e-8bbe-72f557ebc745", "name": "", "x": 38.6051181986353, "y": -122.47354850924762, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a68a1c01-a04c-4af6-b1c8-02ddd1d67e0b", "name": "p1rdt9333lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2a99897f-364d-411e-8bbe-72f557ebc745"}}}}, {"uuid": "de597ed3-ec97-4454-aed4-09dd7a03ce13", "name": "", "x": 38.605233794489806, "y": -122.47322379683654, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "20f93381-3834-4265-b1ec-5767d171ce0a", "name": "p1rlv20182", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "de597ed3-ec97-4454-aed4-09dd7a03ce13"}}}}, {"uuid": "c9d78551-0fd5-43ed-8b68-579cb2336594", "name": "", "x": 38.589035386079345, "y": -122.51706377791538, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e98299cb-8bad-49ea-8627-f3cfe01b9e23", "name": "p1rdt9377lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c9d78551-0fd5-43ed-8b68-579cb2336594"}}}}, {"uuid": "d490540a-d433-41f2-b9e7-eca6fa93417a", "name": "", "x": 38.58906092117887, "y": -122.51702075225897, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fb7a8747-a076-469c-a150-35f6763157ec", "name": "p1rlv20277", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d490540a-d433-41f2-b9e7-eca6fa93417a"}}}}, {"uuid": "26eb7692-c5a5-4207-b2ef-2f5b4fc9f7de", "name": "", "x": 38.554956569072154, "y": -122.5078416303234, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9e37f182-5a60-470d-8f5b-ba145cc27973", "name": "p1rdt9381lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "26eb7692-c5a5-4207-b2ef-2f5b4fc9f7de"}}}}, {"uuid": "cff5bde2-44fa-4d0e-a743-f67d7e951b2c", "name": "", "x": 38.55506084687392, "y": -122.50759593781095, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3f23405b-432f-45ff-a7b1-0b7147cddfc8", "name": "p1rlv20281", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cff5bde2-44fa-4d0e-a743-f67d7e951b2c"}}}}, {"uuid": "095f699d-7656-4788-95ba-fb5548a06de8", "name": "", "x": 38.55481960527157, "y": -122.50809108490742, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9e5718ad-0b70-4ea4-b2f2-31f0ea5c5d5b", "name": "p1rlv20309", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "095f699d-7656-4788-95ba-fb5548a06de8"}}}}, {"uuid": "afabc397-de9a-4321-856d-b35e976cd844", "name": "", "x": 38.658604016675696, "y": -122.44126850823349, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "abd09ea6-221c-47d9-beec-1062e0dd4aa7", "name": "p1rdt9384lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "afabc397-de9a-4321-856d-b35e976cd844"}}}}, {"uuid": "fbc5a56d-565b-4454-b6d6-7d72d0bfe51f", "name": "", "x": 38.65866093691784, "y": -122.4412720400857, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25837ab0-0fb8-4346-94ad-561ff9ff7f0c", "name": "p1rlv20284", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fbc5a56d-565b-4454-b6d6-7d72d0bfe51f"}}}}, {"uuid": "1d71f24e-2901-42c3-a813-a3acd99d09c3", "name": "", "x": 38.55588955861104, "y": -122.50676017270496, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fc7e0a25-d6d6-4b07-b3dc-4fe5646915e2", "name": "p1rdt9396lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d71f24e-2901-42c3-a813-a3acd99d09c3"}}}}, {"uuid": "25e2bcaf-cac0-4e8f-91e9-d28d24280f7e", "name": "", "x": 38.55589072497332, "y": -122.5068140409716, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "da62d78e-e221-423a-8da0-8d36ce1f7508", "name": "p1rlv20300", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "25e2bcaf-cac0-4e8f-91e9-d28d24280f7e"}}}}, {"uuid": "1b4f1d5d-7d2c-437f-90c6-9aa0e49f8009", "name": "", "x": 38.62027530963716, "y": -122.47939957508689, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8180ee90-a46e-4d85-9742-d47b24f5e169", "name": "p1rdt9413lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1b4f1d5d-7d2c-437f-90c6-9aa0e49f8009"}}}}, {"uuid": "9fc146a4-e41f-4cf3-b41f-4854efeea77d", "name": "", "x": 38.62004720247463, "y": -122.47879011072362, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c23afdc0-ab93-4d43-8eec-613eab21cd74", "name": "p1rlv20333", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9fc146a4-e41f-4cf3-b41f-4854efeea77d"}}}}, {"uuid": "02cb45f3-fe94-4dd8-9573-6a0f478a879c", "name": "", "x": 38.620529773744515, "y": -122.47990087956352, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4b5d2dfa-895b-4afc-a7fe-449960adba41", "name": "p1rlv20358", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "02cb45f3-fe94-4dd8-9573-6a0f478a879c"}}}}, {"uuid": "e94a07cf-e35c-478c-a311-9ca498f5c3ae", "name": "", "x": 38.591063428696835, "y": -122.52153986948501, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a015abb-ec63-4b31-9314-283b8499646e", "name": "p1rdt9463lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e94a07cf-e35c-478c-a311-9ca498f5c3ae"}}}}, {"uuid": "25620ccf-e94e-4be9-bfe7-91878762980d", "name": "", "x": 38.59108896543552, "y": -122.52149684417888, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e4b5327a-85a3-496c-859c-f887a38513cd", "name": "p1rlv20432", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "25620ccf-e94e-4be9-bfe7-91878762980d"}}}}, {"uuid": "cca09bca-16e9-499c-b095-0c1950ecc547", "name": "", "x": 38.57979403494598, "y": -122.51418658341599, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4dbe1628-cd17-4f37-af2b-dd752c290fa4", "name": "p1rdt9468lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cca09bca-16e9-499c-b095-0c1950ecc547"}}}}, {"uuid": "e157a12b-a7d2-4147-bcd2-b3ab3a70ddae", "name": "", "x": 38.57980836535011, "y": -122.514237347121, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c37708d8-1e83-4e76-ac7f-0d29ba6b7c4e", "name": "p1rlv20451", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e157a12b-a7d2-4147-bcd2-b3ab3a70ddae"}}}}, {"uuid": "f80fb467-df08-4b12-85da-2108e641dcd6", "name": "", "x": 38.64987390299784, "y": -122.46561468579733, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "09613257-d4cb-4c50-b35a-8aefc637c0c9", "name": "p1rdt9469lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f80fb467-df08-4b12-85da-2108e641dcd6"}}}}, {"uuid": "a8be240d-00b9-4f9d-adf9-0f1168744f6a", "name": "", "x": 38.649915988400906, "y": -122.4656103988514, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a4e21b79-d2be-4a53-be46-32331e61f89c", "name": "p1rlv20453", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8be240d-00b9-4f9d-adf9-0f1168744f6a"}}}}, {"uuid": "8860d0ef-e55e-447d-93df-ae60d3936aa0", "name": "", "x": 38.65045746320294, "y": -122.46638434729005, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1ab8727-2758-4513-8a7d-e02381faf1e4", "name": "p1rdt9470lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8860d0ef-e55e-447d-93df-ae60d3936aa0"}}}}, {"uuid": "057230d4-bf01-4042-ad61-30c7db0f897e", "name": "", "x": 38.650379000628085, "y": -122.46634293498136, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9dfcfdbf-0051-4eef-bea6-97446cee21e4", "name": "p1rlv20459", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "057230d4-bf01-4042-ad61-30c7db0f897e"}}}}, {"uuid": "5cf1438a-80c4-4c22-aaed-3469743e85b4", "name": "", "x": 38.65057767311801, "y": -122.46643339731892, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9af153ed-ed39-4433-ac12-19dfdb7b6bef", "name": "p1rlv20499", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5cf1438a-80c4-4c22-aaed-3469743e85b4"}}}}, {"uuid": "7b65f4e9-580d-47dc-b34e-28f81d668390", "name": "", "x": 38.56377829551582, "y": -122.5132715911584, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c14c3211-a0d5-464f-820c-cab04764d907", "name": "p1rdt9473lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7b65f4e9-580d-47dc-b34e-28f81d668390"}}}}, {"uuid": "8a3e10a2-8282-43c8-b4da-fda1b1669c94", "name": "", "x": 38.5639962321023, "y": -122.51298713404236, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4759390d-43ec-45c9-9cca-320020dc1150", "name": "p1rlv20465", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8a3e10a2-8282-43c8-b4da-fda1b1669c94"}}}}, {"uuid": "cb26fbb7-596c-4de9-b34e-101dc678ca65", "name": "", "x": 38.5746780928461, "y": -122.51786998579286, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6a8f268-6a5a-4b23-bd91-53c6b031442a", "name": "p1rdt9479lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb26fbb7-596c-4de9-b34e-101dc678ca65"}}}}, {"uuid": "e39e8d8e-0d46-4628-94c5-07b594071e7e", "name": "", "x": 38.574723226995864, "y": -122.51801181420616, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cacd3e49-55aa-4f05-bd7d-ae8aba0af87f", "name": "p1rlv20502", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e39e8d8e-0d46-4628-94c5-07b594071e7e"}}}}, {"uuid": "7c12f6c5-55e6-49d1-bd94-2352ee3b1586", "name": "", "x": 38.65513908341776, "y": -122.34387958999741, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ac361065-6b3c-4ac6-96d5-9b474eb3b80f", "name": "p1rdt16638lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7c12f6c5-55e6-49d1-bd94-2352ee3b1586"}}}}, {"uuid": "0207b470-cf6d-4629-9b3c-ad531fda5dab", "name": "", "x": 38.655190554276075, "y": -122.34392111738993, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aa4eed95-33b7-4827-8744-52d14149b386", "name": "p1rlv38126", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0207b470-cf6d-4629-9b3c-ad531fda5dab"}}}}, {"uuid": "533bb500-770c-4d2c-9cc1-28775d01f44e", "name": "", "x": 38.65630824124314, "y": -122.34286109532569, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bae9a352-584d-4cf0-9ebd-eb280b684e78", "name": "p1rdt16725lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "533bb500-770c-4d2c-9cc1-28775d01f44e"}}}}, {"uuid": "ff5a7ad7-1d65-4c62-8ae0-267a310fb193", "name": "", "x": 38.65627492173817, "y": -122.34284238795301, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6cbb9976-253c-4863-899f-9218c4496688", "name": "p1rlv38269", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ff5a7ad7-1d65-4c62-8ae0-267a310fb193"}}}}, {"uuid": "f8eacce3-9525-4b06-8b1b-f7019fa7c45f", "name": "", "x": 38.62034621533613, "y": -122.43765627693834, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6bfb33cd-0cf1-455d-81e7-3d0472fa1b41", "name": "p1rdt8012", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f8eacce3-9525-4b06-8b1b-f7019fa7c45f"}}}}, {"uuid": "804049e0-ce7b-491e-99fa-e410e6a6a3be", "name": "", "x": 38.618246403950295, "y": -122.43508018831336, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e261b565-1f57-4cdc-bdd6-e045ee55d290", "name": "p1rdt7983", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "804049e0-ce7b-491e-99fa-e410e6a6a3be"}}}}, {"uuid": "6bfa5767-f2b2-4c1a-99b7-7b23d5fb2141", "name": "", "x": 38.620540310627334, "y": -122.43796845936235, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3f83d22a-fa1e-4a4e-aab9-a9dea8ee06e5", "name": "p1rdt8034", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6bfa5767-f2b2-4c1a-99b7-7b23d5fb2141"}}}}, {"uuid": "d27b544e-9687-455f-ba58-9ed436c5a572", "name": "", "x": 38.622378075951055, "y": -122.4397117047474, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "21e15d54-eab8-4204-9ed6-407fd8684700", "name": "p1rdt7954", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d27b544e-9687-455f-ba58-9ed436c5a572"}}}}, {"uuid": "81d253a0-1d96-4c57-8981-717e38dcce21", "name": "", "x": 38.62277584721677, "y": -122.43997282390552, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "016e4575-cd41-4993-be9b-5e5236a139ae", "name": "p1rdt7973", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "81d253a0-1d96-4c57-8981-717e38dcce21"}}}}, {"uuid": "4d3f203c-47be-4223-8720-2528ecc712e5", "name": "", "x": 38.62402950921016, "y": -122.44277403473237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ea481f8-b9c7-4067-9bfb-4f7cdc5dee15", "name": "p1rdt5172", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d3f203c-47be-4223-8720-2528ecc712e5"}}}}, {"uuid": "0e03e381-7790-4e61-94b7-9d458b302a4d", "name": "", "x": 38.62300895388021, "y": -122.44290656824234, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16712e10-4c7f-428b-917b-135ab3c2d4b3", "name": "p1rdt5155", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0e03e381-7790-4e61-94b7-9d458b302a4d"}}}}, {"uuid": "bf821b66-093f-4603-ad7e-32bed64b35bc", "name": "", "x": 38.623287659052096, "y": -122.4427643158668, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "afc636ed-f90c-4c48-822b-e86890d36f3b", "name": "p1rdt5155-p1rdt5172x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bf821b66-093f-4603-ad7e-32bed64b35bc"}}}}, {"uuid": "0363d42a-c376-4ae4-8b0d-bb484444fee6", "name": "", "x": 38.623116980624474, "y": -122.4447782161465, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9c289632-ba52-4b65-b6da-ac76b1477246", "name": "p1rdt5201", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0363d42a-c376-4ae4-8b0d-bb484444fee6"}}}}, {"uuid": "840097f5-3c7a-4849-b762-f137bdea4c16", "name": "", "x": 38.62329628881549, "y": -122.44457929911667, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ee606236-08d7-4258-96c9-e9104f15b467", "name": "p1rdt5159-p1rdt5201x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "840097f5-3c7a-4849-b762-f137bdea4c16"}}}}, {"uuid": "7f834bdd-4114-42ce-9e63-53bc785fec0a", "name": "", "x": 38.6234306387608, "y": -122.44440819183146, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "90fb2270-4759-4779-80c1-7f93d66e1c53", "name": "p1rdt5159", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7f834bdd-4114-42ce-9e63-53bc785fec0a"}}}}, {"uuid": "37141299-89a0-41ed-982a-51081d6b3d42", "name": "", "x": 38.62215863028796, "y": -122.44620579183537, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "86d3f96e-ffe2-459f-a2f1-b63d7bf138b8", "name": "p1rdt5180-p1rdt5201x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "37141299-89a0-41ed-982a-51081d6b3d42"}}}}, {"uuid": "6e4501c1-afa6-454f-bb4e-7186b7feb938", "name": "", "x": 38.615444643589946, "y": -122.4340993039006, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6fec8a81-a151-4d8f-adc7-6d6d87d7759f", "name": "p1rdt5923", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6e4501c1-afa6-454f-bb4e-7186b7feb938"}}}}, {"uuid": "da1cc01b-26a4-4326-b5b2-37141fb8691d", "name": "", "x": 38.61722132993687, "y": -122.42939704924423, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "14b429c3-41da-4123-b661-40cbdfaf33e0", "name": "p1rdt8346", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "da1cc01b-26a4-4326-b5b2-37141fb8691d"}}}}, {"uuid": "5a082e29-1507-4b02-b095-69b11f571dda", "name": "", "x": 38.617041139275344, "y": -122.43743292025952, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48e4b67a-0a47-48f0-b787-0a639db89caa", "name": "p1rdt7988", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5a082e29-1507-4b02-b095-69b11f571dda"}}}}, {"uuid": "4ed19a51-3310-41a4-aff9-28d8a46ca419", "name": "", "x": 38.62223049910566, "y": -122.44617598691588, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "893d2436-cd6c-40ad-90af-64ba1ac23f6e", "name": "p1rdt5180-p1rdt7988x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ed19a51-3310-41a4-aff9-28d8a46ca419"}}}}, {"uuid": "43402875-9dea-4473-be24-75b831aa6d6f", "name": "", "x": 38.62337315716766, "y": -122.45650688359399, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0089e5ea-d706-4a74-812f-654ae73eabcf", "name": "p1rdt8456", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "43402875-9dea-4473-be24-75b831aa6d6f"}}}}, {"uuid": "4cea5a72-5bb5-4f43-8eda-1ef360771178", "name": "", "x": 38.62156927448908, "y": -122.45679446794591, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "13b8cfc1-d8eb-4f47-b024-c1daacf3771d", "name": "p1rdt8447", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4cea5a72-5bb5-4f43-8eda-1ef360771178"}}}}, {"uuid": "cb3e167d-c2cb-4736-8f66-8143d56bd1cf", "name": "", "x": 38.6238198104542, "y": -122.456272029401, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "34054ef8-8942-4471-ac14-43c6a37e5a16", "name": "p1rdt8414-p1rdt8456x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb3e167d-c2cb-4736-8f66-8143d56bd1cf"}}}}, {"uuid": "8cb1f65f-d4fc-4d14-9857-6d98b2cc3094", "name": "", "x": 38.610218492856475, "y": -122.45635700104502, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8a53624b-8538-4cce-b588-c774875af31b", "name": "p1rdt6274", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8cb1f65f-d4fc-4d14-9857-6d98b2cc3094"}}}}, {"uuid": "fdc5de1c-ebb2-4bff-8945-795a93fc75f8", "name": "", "x": 38.61055108690851, "y": -122.4555659540378, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3ac93b23-1041-486e-a16e-861082c92f35", "name": "p1rdt6272-p1rdt6274x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fdc5de1c-ebb2-4bff-8945-795a93fc75f8"}}}}, {"uuid": "e57a56c3-8dcc-4aa1-91fc-48c8b8f06c8e", "name": "", "x": 38.610520720245056, "y": -122.45545884146962, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "034bda10-d48e-449c-9255-247cbf718683", "name": "p1rdt6272", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e57a56c3-8dcc-4aa1-91fc-48c8b8f06c8e"}}}}, {"uuid": "c16f990c-0ff1-414b-8380-ee7d791b0f96", "name": "", "x": 38.61197078011171, "y": -122.45741942756798, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0a75c5e2-2277-42b4-87d4-6eadff5c06f1", "name": "p1rdt6271", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c16f990c-0ff1-414b-8380-ee7d791b0f96"}}}}, {"uuid": "2dd1c6fe-9e94-4b4a-97e5-0fe2f1fb7e6d", "name": "", "x": 38.61207637689822, "y": -122.45737706222091, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "28954596-f060-4fa8-9f13-dfaa633bb739", "name": "p1rdt6270-p1rdt6271xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2dd1c6fe-9e94-4b4a-97e5-0fe2f1fb7e6d"}}}}, {"uuid": "0ca652d0-115a-441c-8eb8-5cf8c840706d", "name": "", "x": 38.6128563737481, "y": -122.45907473259327, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "898611f5-c343-4cca-8e5e-60cf0bfd796b", "name": "p1rdt6270-p1rdt6271xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0ca652d0-115a-441c-8eb8-5cf8c840706d"}}}}, {"uuid": "496b5d51-e112-464a-bb9c-4049894d8dee", "name": "", "x": 38.613028815797925, "y": -122.45946476660588, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b81bd5c2-96bb-445e-9eb8-d72360fd8a94", "name": "p1rdt6270-p1rdt6271xxxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "496b5d51-e112-464a-bb9c-4049894d8dee"}}}}, {"uuid": "d05a1a5c-0920-4097-babd-b5923ba0ddbd", "name": "", "x": 38.603726878082334, "y": -122.46288947925576, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "76f6a27f-0e4f-48b8-9dbd-31c6ffc4ec75", "name": "p1rdt7579", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d05a1a5c-0920-4097-babd-b5923ba0ddbd"}}}}, {"uuid": "417b978b-18e3-4121-a1bf-51f957cfd9dd", "name": "", "x": 38.60179587168076, "y": -122.46429351511154, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fa33ca9e-e16d-4c49-8a70-c6c30cf7b038", "name": "p1rdt7564", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "417b978b-18e3-4121-a1bf-51f957cfd9dd"}}}}, {"uuid": "38d20a1b-d399-4ab6-bf7c-aae66fa23a4c", "name": "", "x": 38.601539075146476, "y": -122.46251347070827, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8f2dabc2-0b52-490c-b13a-32c268f6bd33", "name": "p1rdt7588", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "38d20a1b-d399-4ab6-bf7c-aae66fa23a4c"}}}}, {"uuid": "4e241cc8-3082-4fd0-88d1-fc267588d21d", "name": "", "x": 38.60742474012847, "y": -122.4582846144434, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0f6de990-0988-4126-86ca-d1fd72c555fe", "name": "p1rdt7554", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4e241cc8-3082-4fd0-88d1-fc267588d21d"}}}}, {"uuid": "9b8ba534-6195-4b35-89f5-2a4c3c722bf4", "name": "", "x": 38.607801140709334, "y": -122.45761981019629, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2bdb2b51-0526-4995-bb5e-a2bd495488d4", "name": "p1rdt7554-p1rdt7570x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9b8ba534-6195-4b35-89f5-2a4c3c722bf4"}}}}, {"uuid": "4c45e384-de6e-47e6-a9ad-b6aae63c720c", "name": "", "x": 38.607753208324574, "y": -122.4554757397103, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f239ef4e-83f0-4a2c-ada3-8e30cef38472", "name": "p1rdt7559", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c45e384-de6e-47e6-a9ad-b6aae63c720c"}}}}, {"uuid": "3156fc94-96bd-4a53-b84b-3ddb7c65c545", "name": "", "x": 38.60740955675949, "y": -122.45440672587179, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ff343735-753a-48ca-92b1-ea778c9e0b5c", "name": "p1rdt7559-p1rdt8015x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3156fc94-96bd-4a53-b84b-3ddb7c65c545"}}}}, {"uuid": "e810c55c-bf24-40b9-8584-0ea6ba45bdd3", "name": "", "x": 38.60632927470628, "y": -122.45140187652409, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cc543f54-740b-4a7f-b1c5-eb3783a8ade0", "name": "p1rdt8015", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e810c55c-bf24-40b9-8584-0ea6ba45bdd3"}}}}, {"uuid": "7bf553bc-03a7-4134-b7e6-ce6194ed1aad", "name": "", "x": 38.60785880448065, "y": -122.45543337407624, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "09814176-7891-4fe1-addf-b47aa106c40d", "name": "p1rdt7559-p1rdt7570xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7bf553bc-03a7-4134-b7e6-ce6194ed1aad"}}}}, {"uuid": "2a3f447c-2df8-43bd-98a5-56059107b4e9", "name": "", "x": 38.607591729699735, "y": -122.45675980389136, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1dbec6c9-5c87-4f56-bd92-4a30d39ad094", "name": "p1rdt7559-p1rdt7570x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2a3f447c-2df8-43bd-98a5-56059107b4e9"}}}}, {"uuid": "3e452e28-6a28-4350-8544-cdbfbe2a921a", "name": "", "x": 38.601892868535366, "y": -122.45542862865831, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "db899c48-a801-4f83-b59d-e587ba80019d", "name": "p1rdt7552", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e452e28-6a28-4350-8544-cdbfbe2a921a"}}}}, {"uuid": "373ec05f-2d67-4736-8ebe-e41faea4f4ff", "name": "", "x": 38.60005814605219, "y": -122.4516448455036, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "93a5388e-ffd7-403e-b6cf-26b7e81feed1", "name": "p1rdt7986", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "373ec05f-2d67-4736-8ebe-e41faea4f4ff"}}}}, {"uuid": "fb5c1be3-22fd-4000-8e6b-267de4b40db1", "name": "", "x": 38.60314520391628, "y": -122.45852350850332, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2f0f3112-1395-48bf-88c1-8dd4b171478d", "name": "p1rdt7551", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fb5c1be3-22fd-4000-8e6b-267de4b40db1"}}}}, {"uuid": "928e2eec-1973-4044-bad0-d4fcdf464563", "name": "", "x": 38.60020849529689, "y": -122.46072753146206, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fc6bd64f-1ad3-4bd9-b590-7d4b673a94b5", "name": "p1rdt7561", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "928e2eec-1973-4044-bad0-d4fcdf464563"}}}}, {"uuid": "1741a3e1-3d98-4b45-9891-d9daf0f8513c", "name": "", "x": 38.60111102829196, "y": -122.46101936494843, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dead8520-e2f5-499b-9316-77780f9b1dfe", "name": "p1rdt7550", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1741a3e1-3d98-4b45-9891-d9daf0f8513c"}}}}, {"uuid": "af4f08f0-94de-4726-88ae-e00fcd4eaa36", "name": "", "x": 38.597594406004944, "y": -122.45741331498996, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f28de397-0db4-486a-8ce6-9f65c68703b3", "name": "p1rdt8434", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "af4f08f0-94de-4726-88ae-e00fcd4eaa36"}}}}, {"uuid": "45dc3818-21a6-4584-80fc-2019452cf93a", "name": "", "x": 38.597440760670644, "y": -122.45596586818255, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "184f95d4-cde1-4bf1-8a74-ebc7097cb10e", "name": "p1rdt8450", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "45dc3818-21a6-4584-80fc-2019452cf93a"}}}}, {"uuid": "799600d7-d852-4c9b-8f6e-1102fdded8ce", "name": "", "x": 38.597703329969455, "y": -122.45880555075607, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bbfe31b1-38ce-4ae4-9143-bf08c81617e8", "name": "p1rdt8440", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "799600d7-d852-4c9b-8f6e-1102fdded8ce"}}}}, {"uuid": "44c7d264-7191-4b9e-acb0-88e311db57b3", "name": "", "x": 38.59658206909063, "y": -122.45932321062192, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "516ca275-0d8e-4a9a-ab59-89cb66b95d93", "name": "p1rdt8436-p1rdt8440x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "44c7d264-7191-4b9e-acb0-88e311db57b3"}}}}, {"uuid": "9df146b4-516e-4ea5-bda7-c1a73ae15633", "name": "", "x": 38.59579222604902, "y": -122.46002037573007, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fcc42825-2690-4965-a99b-e78285a9b84e", "name": "p1rdt8436", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9df146b4-516e-4ea5-bda7-c1a73ae15633"}}}}, {"uuid": "c6913b29-d9ba-47a3-a192-1193e7e5403c", "name": "", "x": 38.596573779354905, "y": -122.45753186177956, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5f6e9b43-ceca-4a80-9569-696375a6ff5b", "name": "p1rdt8440-p1rdt8444x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c6913b29-d9ba-47a3-a192-1193e7e5403c"}}}}, {"uuid": "0a73aed7-d223-4038-9ac0-5b92a4d1987c", "name": "", "x": 38.5957635117617, "y": -122.45709408297363, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "685fbdbf-47af-4cc2-97ce-354dd04ce915", "name": "p1rdt8444", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a73aed7-d223-4038-9ac0-5b92a4d1987c"}}}}, {"uuid": "bf112380-b4c4-4738-a1d4-d798c1f01364", "name": "", "x": 38.599951855708426, "y": -122.46051919867074, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c0075333-98fe-4ee8-bb64-a18119b817c0", "name": "p1rdt7555", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bf112380-b4c4-4738-a1d4-d798c1f01364"}}}}, {"uuid": "f068e58c-2e16-4f15-8bf8-2f3eae98f96a", "name": "", "x": 38.601199336202434, "y": -122.46001207089114, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1e068b84-fbff-4546-b708-ca91ffe92b69", "name": "p1rdt7551-p1rdt7561x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f068e58c-2e16-4f15-8bf8-2f3eae98f96a"}}}}, {"uuid": "5cb7897b-26e3-4fb1-8110-0c2b58852939", "name": "", "x": 38.60649944562754, "y": -122.45751394231347, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1d8c14d0-8247-4a44-98c1-4534aa9037a2", "name": "p1rdt7551-p1rdt7574x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5cb7897b-26e3-4fb1-8110-0c2b58852939"}}}}, {"uuid": "7080975e-bc07-4286-ac0c-b487ce747aa8", "name": "", "x": 38.60635191905131, "y": -122.45581093557001, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ddf629eb-ea60-4fce-b731-7ebb33665829", "name": "p1rdt7553", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7080975e-bc07-4286-ac0c-b487ce747aa8"}}}}, {"uuid": "ece1113e-bcd2-4196-a2a1-14453f132e65", "name": "", "x": 38.606309626265485, "y": -122.45581243510644, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d4307e78-304a-4175-8e81-9cb23d99f394", "name": "p1rdt7572", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ece1113e-bcd2-4196-a2a1-14453f132e65"}}}}, {"uuid": "cbdc1d01-82c3-4ee4-babc-404553de25e5", "name": "", "x": 38.60642288565036, "y": -122.45576012137332, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f00dd033-8e7c-43af-bd16-1de2954e07be", "name": "p1rdt7553-p1rdt7574xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cbdc1d01-82c3-4ee4-babc-404553de25e5"}}}}, {"uuid": "c187bbb9-4399-4b90-a4f6-ea17d84c91b1", "name": "", "x": 38.60650133107034, "y": -122.45676802538416, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7744d8d9-73a8-4274-9c91-5542620942f5", "name": "p1rdt7553-p1rdt7574x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c187bbb9-4399-4b90-a4f6-ea17d84c91b1"}}}}, {"uuid": "e6eab6d5-ecec-4a44-9135-ace4449f9a3f", "name": "", "x": 38.616823684704634, "y": -122.45485169561282, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a9722136-480b-44cb-8b0e-0b3165712688", "name": "p1rdt5179-p1rdt6273x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e6eab6d5-ecec-4a44-9135-ace4449f9a3f"}}}}, {"uuid": "cbcad839-30cf-45d7-8aeb-5541d365147b", "name": "", "x": 38.61884536658003, "y": -122.45181991735679, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d22f1247-b756-4498-8cf8-fef7d1e859ff", "name": "p1rdt5179", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cbcad839-30cf-45d7-8aeb-5541d365147b"}}}}, {"uuid": "32980d01-7147-4efb-9208-6924bc7a6c36", "name": "", "x": 38.620392420969665, "y": -122.45625723062152, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "28af960e-6f27-483a-8029-0c5f1641f51d", "name": "p1rdt8408", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "32980d01-7147-4efb-9208-6924bc7a6c36"}}}}, {"uuid": "6eb63711-311c-48b0-a200-7708a569b3be", "name": "", "x": 38.62105939691115, "y": -122.45567255802798, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "433162b1-2a9b-4187-ba28-ec57503d76f6", "name": "p1rdt8458", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6eb63711-311c-48b0-a200-7708a569b3be"}}}}, {"uuid": "34790c46-d3a6-4ef4-a144-f8aa7791f306", "name": "", "x": 38.61794197262064, "y": -122.4571451861387, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "07f340ca-58c2-4331-8265-a39a45c87b75", "name": "p1rdt8439", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "34790c46-d3a6-4ef4-a144-f8aa7791f306"}}}}, {"uuid": "2882cbbd-35ac-40a5-8eba-2fa1353c5ab1", "name": "", "x": 38.619657499896064, "y": -122.45651946734527, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3430524c-820d-4f17-ba1b-377aeef4bbcd", "name": "p1rdt8408-p1rdt8439x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2882cbbd-35ac-40a5-8eba-2fa1353c5ab1"}}}}, {"uuid": "950056a4-f77d-43ed-abc8-f0ebb5f1eacf", "name": "", "x": 38.61643197384722, "y": -122.45750913060422, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "19d5304c-574f-4646-8095-d2dcbbea86e7", "name": "p1rdt6278-p1rdt8439x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "950056a4-f77d-43ed-abc8-f0ebb5f1eacf"}}}}, {"uuid": "46372221-c5d6-4e25-9937-70ae8e4a5744", "name": "", "x": 38.61757719949048, "y": -122.46073569903709, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a8c69243-872f-4e25-9d03-82692bbf8779", "name": "p1rdt8405-p1rdt8445x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "46372221-c5d6-4e25-9937-70ae8e4a5744"}}}}, {"uuid": "0193f084-2414-465f-8507-c518ab5551df", "name": "", "x": 38.61750461268671, "y": -122.46257773961285, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1e3ecdca-4b27-4a9d-8599-637924e86602", "name": "p1rdt8405-p1rdt8445xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0193f084-2414-465f-8507-c518ab5551df"}}}}, {"uuid": "559151e0-4417-49f0-a82d-3d35634b96df", "name": "", "x": 38.61747453032813, "y": -122.46077804087776, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bc0ee90f-1f9e-435e-bac4-86a4688c48fc", "name": "p1rdt8445", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "559151e0-4417-49f0-a82d-3d35634b96df"}}}}, {"uuid": "bd56f243-69e2-4d25-88e4-d5062a621ab9", "name": "", "x": 38.58085055283345, "y": -122.50956971443162, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bf648a0d-3262-4150-892b-55c3b117050a", "name": "p1rdt6500-p1rdt6519xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bd56f243-69e2-4d25-88e4-d5062a621ab9"}}}}, {"uuid": "4f978e8c-71c9-4108-8bd4-dd7e04c67d03", "name": "", "x": 38.58085769734513, "y": -122.50951590453553, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5789c3b2-eb91-4e4c-85e8-24f5893e1a2c", "name": "p1rdt6500-p1rdt6519xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4f978e8c-71c9-4108-8bd4-dd7e04c67d03"}}}}, {"uuid": "1a89ad58-99e8-48ca-b84d-4d30890fd198", "name": "", "x": 38.580324139975936, "y": -122.51120115232804, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c0824c21-244b-4d4e-85d6-238ac4908b5a", "name": "p1rdt6505-p1rdt6508x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1a89ad58-99e8-48ca-b84d-4d30890fd198"}}}}, {"uuid": "a9ea404f-0da3-492e-ad2b-10b63708892f", "name": "", "x": 38.57943061458019, "y": -122.51076650882104, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eb1c1e50-902d-443d-8c9a-b728d2f6b6f1", "name": "p1rdt6505", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a9ea404f-0da3-492e-ad2b-10b63708892f"}}}}, {"uuid": "845aaad9-1218-47c7-8b04-b96551dfcf6b", "name": "", "x": 38.57967511307611, "y": -122.5126018254279, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "66b7b2e9-7658-4de0-8197-3829c6179353", "name": "p1rdt6510-p1rdt6523x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "845aaad9-1218-47c7-8b04-b96551dfcf6b"}}}}, {"uuid": "0aa3f3d5-e5aa-42de-9954-8117a443544a", "name": "", "x": 38.57908668009848, "y": -122.5112130456528, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "848c04de-e4d5-4520-9dce-0073776c2ae4", "name": "p1rdt6510", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0aa3f3d5-e5aa-42de-9954-8117a443544a"}}}}, {"uuid": "80fce609-371e-4216-a76f-a73c72f53ba1", "name": "", "x": 38.57473976942866, "y": -122.51780959626444, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e07d8bc1-2f8a-4067-a2a7-b903dd042ce3", "name": "p1rdt5730-p1rdt9479x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "80fce609-371e-4216-a76f-a73c72f53ba1"}}}}, {"uuid": "ae73743c-8548-4137-a180-59f6280b9424", "name": "", "x": 38.57217576563056, "y": -122.51803280458198, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d5897bb2-1f72-4aeb-9090-74e2411b5786", "name": "p1rdt5730", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ae73743c-8548-4137-a180-59f6280b9424"}}}}, {"uuid": "ae5a3785-7653-4bf5-8675-35a3db35f092", "name": "", "x": 38.5747498946316, "y": -122.51790816237944, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e7f9286b-4209-402a-a365-1d27da4efb75", "name": "p1rdt5840-p1rdt9479x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ae5a3785-7653-4bf5-8675-35a3db35f092"}}}}, {"uuid": "693261a2-e33f-420e-98d7-aba12afe2b54", "name": "", "x": 38.57341254858641, "y": -122.51993371906103, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35722d90-049e-4c67-9654-acce0572e6c2", "name": "p1rdt5840", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "693261a2-e33f-420e-98d7-aba12afe2b54"}}}}, {"uuid": "a649e8d5-4a5d-4cc5-af0e-8100bd84e39b", "name": "", "x": 38.576726073438714, "y": -122.52446579115181, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "61ba1001-8b9d-481c-b205-45c6e0beadc1", "name": "p1rdt9298", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a649e8d5-4a5d-4cc5-af0e-8100bd84e39b"}}}}, {"uuid": "5ef16793-c098-41e2-b98c-4f9e4e7eefc7", "name": "", "x": 38.576522299104546, "y": -122.52532815241987, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f4a41fe9-62ce-45ba-abcd-086ba429baa0", "name": "p1rdt9302", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ef16793-c098-41e2-b98c-4f9e4e7eefc7"}}}}, {"uuid": "1dc016b2-4413-4089-9171-3916a1d89cab", "name": "", "x": 38.57714443025326, "y": -122.52236567259841, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3035d22c-c39f-4f07-9fe9-29888b16057d", "name": "p1rdt9310", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1dc016b2-4413-4089-9171-3916a1d89cab"}}}}, {"uuid": "b7ae5a8f-66ef-4d60-9134-78c031712321", "name": "", "x": 38.57657358147667, "y": -122.51940754990198, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "644c5887-31f1-436c-bbf6-dae5a70743a2", "name": "p1rdt9316", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b7ae5a8f-66ef-4d60-9134-78c031712321"}}}}, {"uuid": "8efefa1d-8ecd-4c4d-9e24-01b27035c531", "name": "", "x": 38.57940200391493, "y": -122.5212830170439, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b8721684-5439-482c-b8e5-be330d3cf745", "name": "p1rdt9312", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8efefa1d-8ecd-4c4d-9e24-01b27035c531"}}}}, {"uuid": "f194676e-4380-4328-ab02-daf91a9df474", "name": "", "x": 38.57641631447873, "y": -122.5192328534116, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7011f1dc-1e7d-4961-9a23-620b7f5737af", "name": "p1rdt9311", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f194676e-4380-4328-ab02-daf91a9df474"}}}}, {"uuid": "b9a6ab8a-47b8-4813-b138-81c932fd688f", "name": "", "x": 38.57548870286482, "y": -122.51882223524302, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "95d939ff-e20d-42b3-bb88-f1975f9fa0aa", "name": "p1rdt6518-p1rdt9311x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b9a6ab8a-47b8-4813-b138-81c932fd688f"}}}}, {"uuid": "659d0d06-e371-4b97-a79c-b5e43f8c7802", "name": "", "x": 38.56957251351933, "y": -122.5146506475286, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "77d2122b-cbb7-4844-bbb2-55e939431e50", "name": "p1rdt5729", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "659d0d06-e371-4b97-a79c-b5e43f8c7802"}}}}, {"uuid": "491c68dc-d6da-48bf-ae44-2d31c3d9cc06", "name": "", "x": 38.569500663957065, "y": -122.51470628390435, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "52f308f4-35db-49ec-a599-f8380489f952", "name": "p1rdt5729-p1rdt5731x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "491c68dc-d6da-48bf-ae44-2d31c3d9cc06"}}}}, {"uuid": "73967e47-18f3-483a-b10a-771124b63d48", "name": "", "x": 38.56683955344907, "y": -122.51476612858174, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "95cd61cf-f1cb-4af2-9d3b-e42978642003", "name": "p1rdt5731", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "73967e47-18f3-483a-b10a-771124b63d48"}}}}, {"uuid": "c7c257cd-2ea4-4e0e-9bb1-7f376fac96bf", "name": "", "x": 38.57065927664959, "y": -122.51444197635051, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b55c58cf-153e-4aa3-b099-8a1db05a6ae5", "name": "p1rdt5728", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c7c257cd-2ea4-4e0e-9bb1-7f376fac96bf"}}}}, {"uuid": "8ca253b4-42a5-4f7b-a94f-f26b95862d14", "name": "", "x": 38.57561216943165, "y": -122.51516613679155, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "66ef2ffb-e67d-47eb-ae59-194c538ab861", "name": "p1rdt5728-p1rdt6537x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8ca253b4-42a5-4f7b-a94f-f26b95862d14"}}}}, {"uuid": "34dad3c6-ccba-4a06-b54f-a9247d0f4c5f", "name": "", "x": 38.579768071852676, "y": -122.5141439807202, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9b5695dd-714e-4de1-a63a-f142ff0460e1", "name": "p1rdt9468", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "34dad3c6-ccba-4a06-b54f-a9247d0f4c5f"}}}}, {"uuid": "90fe05b7-f3d0-4489-a2c8-35e8cb9c8b41", "name": "", "x": 38.58086149565407, "y": -122.51897714369541, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e6348d4-7fcb-4546-af84-8ece75b6332f", "name": "p1rdt6502", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "90fe05b7-f3d0-4489-a2c8-35e8cb9c8b41"}}}}, {"uuid": "24c5be44-0224-48e1-b290-3d4953eec426", "name": "", "x": 38.580154407405615, "y": -122.51201736754072, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ddfa01c0-4d12-4f96-ab50-0082ef9914a6", "name": "p1rdt6501-p1rdt9468x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "24c5be44-0224-48e1-b290-3d4953eec426"}}}}, {"uuid": "93db63be-461c-4dab-8933-25baf8c11b03", "name": "", "x": 38.58045994181232, "y": -122.51074519698878, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7e4fd2ed-daa1-4a22-936f-8d51ee928d99", "name": "p1rdt6501-p1rdt9468x_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "93db63be-461c-4dab-8933-25baf8c11b03"}}}}, {"uuid": "10535ec6-eb7b-492e-a01d-5671139f021b", "name": "", "x": 38.58028290845341, "y": -122.51146113028999, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "42f09ae1-037a-4565-9cd2-0187c45b7866", "name": "p1rdt6509-p1rdt6514x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10535ec6-eb7b-492e-a01d-5671139f021b"}}}}, {"uuid": "0679c775-bf98-4471-bcd1-d965416cb97f", "name": "", "x": 38.580317644679276, "y": -122.51149205289134, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0737f6ec-0d5d-4cff-b4b7-9910c7076984", "name": "p1rdt6514", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0679c775-bf98-4471-bcd1-d965416cb97f"}}}}, {"uuid": "ecc88ed7-fb40-4552-8972-44bc465197f2", "name": "", "x": 38.57914402812339, "y": -122.51052209118085, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60b93cd6-c9fc-46ef-8b37-6b14d0773df6", "name": "p1rdt6498-p1rdt6516x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ecc88ed7-fb40-4552-8972-44bc465197f2"}}}}, {"uuid": "36242e7c-2807-441f-bc4d-826953103893", "name": "", "x": 38.578899383271626, "y": -122.51078551451845, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f5c5466f-b7e4-4844-967b-9e8b11c68b44", "name": "p1rdt6498", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "36242e7c-2807-441f-bc4d-826953103893"}}}}, {"uuid": "0317cab2-2dea-4ee4-9adb-5d6193ef7f1b", "name": "", "x": 38.566808328998086, "y": -122.50026076244916, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1f6ad7d-f7ea-4b94-956c-ec4a3b2028d5", "name": "p1rdt7298-p1rdt7313x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0317cab2-2dea-4ee4-9adb-5d6193ef7f1b"}}}}, {"uuid": "7eb6d4fd-b3a0-4a74-bd1c-256d42ed5872", "name": "", "x": 38.56643827491598, "y": -122.50011683345299, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b658bf21-450c-4e6b-9dec-c5023a05fd19", "name": "p1rdt7298", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7eb6d4fd-b3a0-4a74-bd1c-256d42ed5872"}}}}, {"uuid": "a581d35a-62ba-4b17-881e-badaf252f4fd", "name": "", "x": 38.56306630294141, "y": -122.50758361380268, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "28d17238-8db8-41da-960c-317183423576", "name": "p1rdt7036-p1rdt7091xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a581d35a-62ba-4b17-881e-badaf252f4fd"}}}}, {"uuid": "52b1a853-b828-4e73-b319-cc93eab563e6", "name": "", "x": 38.56354447960164, "y": -122.50839891620973, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "770cf0ab-50f1-489b-b2ea-d23ba186d10b", "name": "p1rdt7036-p1rdt7091x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "52b1a853-b828-4e73-b319-cc93eab563e6"}}}}, {"uuid": "54e92f2f-4588-4cda-9b5f-6f20e3c81165", "name": "", "x": 38.56300711787946, "y": -122.50763349737177, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "52068090-b613-46d7-a31f-ad3ca26382d5", "name": "p1rdt7036", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "54e92f2f-4588-4cda-9b5f-6f20e3c81165"}}}}, {"uuid": "3a0dbb41-c169-4ec0-8293-06ea239c1640", "name": "", "x": 38.562803482644604, "y": -122.51371079164413, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "97be7ac3-a710-4de8-a666-276813582cd6", "name": "p1rdt7620", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3a0dbb41-c169-4ec0-8293-06ea239c1640"}}}}, {"uuid": "b5ba243f-bb48-42fc-9d16-bfcab7c4716d", "name": "", "x": 38.56262386822574, "y": -122.51386121629318, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5bddd75e-1974-41ee-ab51-625c7485a573", "name": "p1rdt7627", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b5ba243f-bb48-42fc-9d16-bfcab7c4716d"}}}}, {"uuid": "e16bdb71-55c9-4a8f-8864-3327a56f5392", "name": "", "x": 38.56326190620687, "y": -122.51262082119965, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b3a4dfb4-e1b3-43b9-ae42-b0cec47ff4ad", "name": "p1rdt7311", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e16bdb71-55c9-4a8f-8864-3327a56f5392"}}}}, {"uuid": "4837ebc1-7a64-454a-95d7-ad5dc94def01", "name": "", "x": 38.56382004055108, "y": -122.51327924731947, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e4d8bafa-711d-4fd7-8374-7eeaeb43edcd", "name": "p1rdt9473", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4837ebc1-7a64-454a-95d7-ad5dc94def01"}}}}, {"uuid": "d1d35578-3675-44f4-b9e5-3512fa60f90f", "name": "", "x": 38.56294875123604, "y": -122.51180445263074, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "607c7275-da9a-4620-b019-59a66e98c2e6", "name": "p1rdt7306", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1d35578-3675-44f4-b9e5-3512fa60f90f"}}}}, {"uuid": "aa3b4b1d-2dd2-46e6-b28d-96be15961943", "name": "", "x": 38.5622926191724, "y": -122.5122220982717, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "56d67e3e-46af-4e2c-86a8-191d97b0ce8a", "name": "p1rdt7626", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aa3b4b1d-2dd2-46e6-b28d-96be15961943"}}}}, {"uuid": "8d521c86-54cb-4653-b5c6-8d9cae9e2cb8", "name": "", "x": 38.56302679357027, "y": -122.51026940176808, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3a65c4d3-2fc6-48c8-b944-68c4229db3dd", "name": "p1rdt7302", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8d521c86-54cb-4653-b5c6-8d9cae9e2cb8"}}}}, {"uuid": "a9e57660-7319-4bfc-a3d2-fcf715fdcfa9", "name": "", "x": 38.56309662911135, "y": -122.5097294573527, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "01c9d31d-c3bb-4950-9bbd-00377c252ddc", "name": "p1rdt7617", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a9e57660-7319-4bfc-a3d2-fcf715fdcfa9"}}}}, {"uuid": "c255184c-f2ed-4139-8383-2022a4b54427", "name": "", "x": 38.56316201817732, "y": -122.50953508538782, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a11cf3d9-90bb-4de8-b637-6ec9128525ec", "name": "p1rdt7617-p1rdt7625x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c255184c-f2ed-4139-8383-2022a4b54427"}}}}, {"uuid": "467d86b5-04a7-4310-966c-b874fd20f77e", "name": "", "x": 38.56129645031688, "y": -122.51025818859465, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "723e2b5c-414c-4f3d-ba23-d2df4bc63e75", "name": "p1rdt7630", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "467d86b5-04a7-4310-966c-b874fd20f77e"}}}}, {"uuid": "6edb6e11-ef87-458b-9e88-98c9e94188dc", "name": "", "x": 38.56190962697, "y": -122.51114576371964, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c7167a2e-9e83-441e-a15b-0256848c3f6d", "name": "p1rdt7616", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6edb6e11-ef87-458b-9e88-98c9e94188dc"}}}}, {"uuid": "b03f4ed4-9c9d-4423-9868-5308cb6b1368", "name": "", "x": 38.56171870357492, "y": -122.50994542040628, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aa48cf27-3b07-4460-ad9c-8d9862238645", "name": "p1rdt7621", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b03f4ed4-9c9d-4423-9868-5308cb6b1368"}}}}, {"uuid": "f92f9ef8-f56e-4f46-aa51-c53171f745c3", "name": "", "x": 38.56318612934499, "y": -122.50945665578503, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "53df7b6e-bd8c-43f2-860d-8869aec5d079", "name": "p1rdt7621-p1rdt7625x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f92f9ef8-f56e-4f46-aa51-c53171f745c3"}}}}, {"uuid": "7cf7bb6c-4bb7-464a-be3a-91cd2396461f", "name": "", "x": 38.55823465883282, "y": -122.50730279853406, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "08d3a02a-555d-4ad1-9b13-d413b7a16eef", "name": "p1rdt7090", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7cf7bb6c-4bb7-464a-be3a-91cd2396461f"}}}}, {"uuid": "3cc41f38-ab18-423e-8f7c-520e94039dcb", "name": "", "x": 38.558375802568776, "y": -122.50792515178091, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3cf406b-69e6-4aee-a6fc-272dad7693a4", "name": "p1rdt7054", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3cc41f38-ab18-423e-8f7c-520e94039dcb"}}}}, {"uuid": "685168bc-7964-448d-9c19-26d528fd2eae", "name": "", "x": 38.55914097308907, "y": -122.50637841432136, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aae22557-7d34-401d-82c9-2d2710ff2915", "name": "p1rdt7069", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "685168bc-7964-448d-9c19-26d528fd2eae"}}}}, {"uuid": "cfab6ae3-c499-4fe4-bd80-17d2c1ba2a07", "name": "", "x": 38.55990008450235, "y": -122.50687823607828, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f614382d-3883-4f6b-b1f6-c8e83d84ee22", "name": "p1rdt7087", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cfab6ae3-c499-4fe4-bd80-17d2c1ba2a07"}}}}, {"uuid": "73e43a9d-07db-47c1-94a1-988b0a844d27", "name": "", "x": 38.561212075777895, "y": -122.50733192344723, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8cebb186-4d9e-4d2c-b0d9-100056d34942", "name": "p1rdt7075", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "73e43a9d-07db-47c1-94a1-988b0a844d27"}}}}, {"uuid": "e987d9bf-0536-4244-9f47-a482bed25baa", "name": "", "x": 38.56134985808187, "y": -122.50795078492914, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "662e2a1c-9a54-4ac3-b478-98e3a478349d", "name": "p1rdt7080", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e987d9bf-0536-4244-9f47-a482bed25baa"}}}}, {"uuid": "db51b889-2677-4f16-9c3d-ee199f25a1a3", "name": "", "x": 38.56137014768056, "y": -122.50849010412762, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "161d6f3b-8bd9-4fa8-9442-c6ff008e8d3d", "name": "p1rdt7619", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "db51b889-2677-4f16-9c3d-ee199f25a1a3"}}}}, {"uuid": "c1c279b4-65c1-4732-a079-66f1aa2a03a9", "name": "", "x": 38.56077220663575, "y": -122.5085365470598, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "105df8ff-ec38-4cd6-b557-c318b4023bd0", "name": "p1rdt7615", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c1c279b4-65c1-4732-a079-66f1aa2a03a9"}}}}, {"uuid": "f337a156-4901-495b-b237-6edff9890775", "name": "", "x": 38.561738481750105, "y": -122.50901203752454, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b9e53141-a773-4127-9558-3887070a8f36", "name": "p1rdt7631", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f337a156-4901-495b-b237-6edff9890775"}}}}, {"uuid": "5ffbe342-0944-4873-987b-e7b8ca04bcbb", "name": "", "x": 38.56310083575031, "y": -122.50950410932236, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "460f5de9-8d4f-468a-b67a-b3b05354a9ce", "name": "p1rdt7625-p1rdt7631x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ffbe342-0944-4873-987b-e7b8ca04bcbb"}}}}, {"uuid": "4a433241-8ed9-4429-92a8-1ce38f0ba622", "name": "", "x": 38.5810553987312, "y": -122.5094376679452, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fec078c2-a5d8-4317-a8ac-bc25772f6358", "name": "p1rdt6515-p1rdt6535xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4a433241-8ed9-4429-92a8-1ce38f0ba622"}}}}, {"uuid": "d74595fc-2533-48bd-a6b5-323641953b72", "name": "", "x": 38.58105426448104, "y": -122.50949283188041, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f5a05d0e-8cf2-4ab8-bdfd-24b8cd12ad67", "name": "p1rdt6515-p1rdt6535xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d74595fc-2533-48bd-a6b5-323641953b72"}}}}, {"uuid": "5e32b2a0-a40b-4f7a-b599-26082e03f999", "name": "", "x": 38.58100676420751, "y": -122.50921942626415, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "04c1e05a-9cbb-4e53-9412-1cffd3976bed", "name": "p1rdt6515-p1rdt6536xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5e32b2a0-a40b-4f7a-b599-26082e03f999"}}}}, {"uuid": "f6d2dfe0-3d18-4c2c-b520-52cbb246dd08", "name": "", "x": 38.58098452673457, "y": -122.50917228702704, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5aa6899b-19a2-41e6-b445-f9fe2536c8d9", "name": "p1rdt6515-p1rdt6536xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f6d2dfe0-3d18-4c2c-b520-52cbb246dd08"}}}}, {"uuid": "995470a2-9f55-4576-97e3-0af02bcc170b", "name": "", "x": 38.58182522217373, "y": -122.50873063816502, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d21061fa-1011-44f7-8a20-26fcf0550f52", "name": "p1rdt8901-p1rdt8902x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "995470a2-9f55-4576-97e3-0af02bcc170b"}}}}, {"uuid": "1974122e-33d7-4966-a35c-5e21f25bdbb4", "name": "", "x": 38.581260006183335, "y": -122.50726033751013, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f23ab51c-56f3-4421-b66e-7cdcf109787d", "name": "p1rdt8901", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1974122e-33d7-4966-a35c-5e21f25bdbb4"}}}}, {"uuid": "6a6c8e90-6c34-4143-ae2d-51c7114ee9e2", "name": "", "x": 38.589021563154894, "y": -122.51711477621102, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "61972a50-ce24-4ec1-8535-402665b55a55", "name": "p1rdt9377", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a6c8e90-6c34-4143-ae2d-51c7114ee9e2"}}}}, {"uuid": "007ab400-5c36-4d26-ae49-7a6f16f74ac6", "name": "", "x": 38.58692523202436, "y": -122.52017146759988, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "84200441-4c26-4966-a4b7-6b91fb43f02e", "name": "p1rdt7301", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "007ab400-5c36-4d26-ae49-7a6f16f74ac6"}}}}, {"uuid": "bffa8083-006e-415c-b5d9-eb6a34928792", "name": "", "x": 38.581769930879894, "y": -122.50871878720857, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "43c862de-b014-4b24-8b34-54dae6edcf5a", "name": "p1rdt8902-p1rdt9377x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bffa8083-006e-415c-b5d9-eb6a34928792"}}}}, {"uuid": "de4f5afd-459e-4cbf-aa49-cd504cb83abb", "name": "", "x": 38.5814032621987, "y": -122.50967321866453, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32e86968-974e-4bcc-b562-1d4209771cf0", "name": "p1rdt8902-p1rdt9377x_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "de4f5afd-459e-4cbf-aa49-cd504cb83abb"}}}}, {"uuid": "6a742844-a654-453e-919e-80445d759442", "name": "", "x": 38.59300712782786, "y": -122.52139582849708, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "37c41a4b-e439-42a1-b9a7-0582c528f0e5", "name": "p1rdt8490", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a742844-a654-453e-919e-80445d759442"}}}}, {"uuid": "b6439b84-94cd-405b-b7ee-069f0c9d898c", "name": "", "x": 38.59104960383041, "y": -122.5215908683816, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "271ab023-4425-40d8-8080-2481c71309b5", "name": "p1rdt9463", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b6439b84-94cd-405b-b7ee-069f0c9d898c"}}}}, {"uuid": "39925f06-fa1e-450f-95b8-ba4e101482e4", "name": "", "x": 38.59323212584656, "y": -122.52027519448441, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "307d9c6d-d5ee-4490-95d3-5a9b1d171e54", "name": "p1rdt8492", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "39925f06-fa1e-450f-95b8-ba4e101482e4"}}}}, {"uuid": "39bd7fbf-764d-4497-aaba-76a78b273ff5", "name": "", "x": 38.59334183117795, "y": -122.52026098011822, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "605c34bc-3f7c-4eb7-8df0-fcd00d261921", "name": "p1rdt7599-p1rdt8492x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "39bd7fbf-764d-4497-aaba-76a78b273ff5"}}}}, {"uuid": "f5319190-a0b2-4d37-9550-a0f2b572bf96", "name": "", "x": 38.59572620360423, "y": -122.50628475874987, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3833996b-287c-4a13-9e7c-6834047f3691", "name": "p1rdt7599-p1rdt8492xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5319190-a0b2-4d37-9550-a0f2b572bf96"}}}}, {"uuid": "f38d56e1-87e0-41f8-b63c-a5019038e230", "name": "", "x": 38.60515752123577, "y": -122.47345444080051, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7f6d3fab-3b83-40c9-85c4-cfeddd0d317a", "name": "p1rdt6226-p1rdt9333xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f38d56e1-87e0-41f8-b63c-a5019038e230"}}}}, {"uuid": "7d2b8e82-3663-4e48-9e89-e8e528cc8114", "name": "", "x": 38.60491485090167, "y": -122.474443511017, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "76f24b35-1b82-4760-9817-80c166073f37", "name": "p1rdt6226-p1rdt9333x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7d2b8e82-3663-4e48-9e89-e8e528cc8114"}}}}, {"uuid": "68343b22-8902-4816-b01b-158043d770b3", "name": "", "x": 38.60439463477556, "y": -122.4756262540049, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d81fc6d7-3400-41d4-91d7-b350d7def98d", "name": "p1rdt6226", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "68343b22-8902-4816-b01b-158043d770b3"}}}}, {"uuid": "4f54bf78-ef0f-44fc-9eab-cf069c5c976f", "name": "", "x": 38.572765543379965, "y": -122.49283903354065, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "36c3c493-ff68-4bb8-a3f4-043c5f847bd3", "name": "p1rdt5650-p1rdt5662x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4f54bf78-ef0f-44fc-9eab-cf069c5c976f"}}}}, {"uuid": "a982988a-244f-4f1c-aac3-e1f1824ffd2c", "name": "", "x": 38.57146366361991, "y": -122.49011602390345, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c8f1c67e-9e29-45a3-a2a3-c2f3493a6898", "name": "p1rdt5650", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a982988a-244f-4f1c-aac3-e1f1824ffd2c"}}}}, {"uuid": "1f15fd9f-5dec-450c-985a-6838f958d682", "name": "", "x": 38.566867108561745, "y": -122.49714650199947, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "81f0e00e-bc49-448a-8e69-0569ed6a8c1a", "name": "p1rdt5658-p1rdt5663x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1f15fd9f-5dec-450c-985a-6838f958d682"}}}}, {"uuid": "f75a053a-7d19-4d97-a68d-be7390bb27ae", "name": "", "x": 38.56722225496197, "y": -122.49589645931059, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e67d07fb-aec5-4120-8254-32bfcd91e378", "name": "p1rdt5658-p1rdt5663xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f75a053a-7d19-4d97-a68d-be7390bb27ae"}}}}, {"uuid": "2fa9bd24-74db-46e1-9028-ab707e76db9d", "name": "", "x": 38.56676442477756, "y": -122.497188761547, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7356d982-36fd-46cb-9300-8889502e8dc8", "name": "p1rdt5663", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2fa9bd24-74db-46e1-9028-ab707e76db9d"}}}}, {"uuid": "825e0b55-7892-413f-9b90-fe1673ed473f", "name": "", "x": 38.563115754357725, "y": -122.50436551560664, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b470fa62-70d4-4cc5-8f7e-b9cda37481e0", "name": "p1rdt7067", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "825e0b55-7892-413f-9b90-fe1673ed473f"}}}}, {"uuid": "a92aaa91-6e7b-4ef0-9c9b-44040d044206", "name": "", "x": 38.562327045687596, "y": -122.50539247201371, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9bb8596a-bcb2-4282-bf1b-9939a9af87d9", "name": "p1rdt7046", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a92aaa91-6e7b-4ef0-9c9b-44040d044206"}}}}, {"uuid": "08c625af-eec7-4383-83b2-1f963a0cd6e9", "name": "", "x": 38.56260404120564, "y": -122.50270471808909, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fb3a9847-70d0-4004-95ef-63884c6c1cdc", "name": "p1rdt7038", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "08c625af-eec7-4383-83b2-1f963a0cd6e9"}}}}, {"uuid": "aeaaaaea-e526-430b-9d4a-421fafdb5bad", "name": "", "x": 38.562387612025795, "y": -122.4991118756889, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ac6e8ccf-75ec-42e0-a3cb-9ab86e2731a4", "name": "p1rdt7070", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aeaaaaea-e526-430b-9d4a-421fafdb5bad"}}}}, {"uuid": "635cd087-1d7c-47b3-b8a7-fec348f9b62f", "name": "", "x": 38.56242616294009, "y": -122.5018066922163, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e9cb2d8d-1991-463c-9e6b-88f5624f28c3", "name": "p1rdt7038-p1rdt7070x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "635cd087-1d7c-47b3-b8a7-fec348f9b62f"}}}}, {"uuid": "bcf8098e-ebef-4e7d-a388-84e59af95fb8", "name": "", "x": 38.55588435346, "y": -122.5067067908326, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0a597011-5e60-46fe-90d6-85728ff0ffa3", "name": "p1rdt9396", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bcf8098e-ebef-4e7d-a388-84e59af95fb8"}}}}, {"uuid": "09a7dcb1-00b7-4ecb-a625-2d5c4eed9235", "name": "", "x": 38.55491482364518, "y": -122.50783397819646, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b5791345-57dc-4f54-ab54-ea63e6a54ee0", "name": "p1rdt9381", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "09a7dcb1-00b7-4ecb-a625-2d5c4eed9235"}}}}, {"uuid": "53098f16-a96d-4396-ad7d-244d0c2c5f88", "name": "", "x": 38.557265355979126, "y": -122.50588266860625, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ac70c13b-5f4f-45f3-880a-b4b476ea552a", "name": "p1rdt7088", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "53098f16-a96d-4396-ad7d-244d0c2c5f88"}}}}, {"uuid": "c3e8351c-dd1c-4e18-b0d2-d7247c861a1f", "name": "", "x": 38.55764619612384, "y": -122.50520475670933, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "31cd4834-477f-4060-8efd-0504c8e8eaa9", "name": "p1rdt7089", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c3e8351c-dd1c-4e18-b0d2-d7247c861a1f"}}}}, {"uuid": "d29fd631-620d-43b6-846e-6fbd7db41afb", "name": "", "x": 38.55961566604152, "y": -122.50276328297903, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75947ffd-3765-443b-bef8-b6af746ef624", "name": "p1rdt7061", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d29fd631-620d-43b6-846e-6fbd7db41afb"}}}}, {"uuid": "81184bc6-d55f-4e11-abb5-4dbf0edbf6ab", "name": "", "x": 38.55890205970878, "y": -122.50382809113916, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "324f5d62-9feb-4fe4-bc1b-3dcf01898148", "name": "p1rdt7061-p1rdt7089x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "81184bc6-d55f-4e11-abb5-4dbf0edbf6ab"}}}}, {"uuid": "d9a8273a-d0fb-452e-b442-66d402d6ecf2", "name": "", "x": 38.560425566891645, "y": -122.50182050287499, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "84578de8-d5de-41fe-b637-42425e97b7db", "name": "p1rdt7061-p1rdt7070x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d9a8273a-d0fb-452e-b442-66d402d6ecf2"}}}}, {"uuid": "adff7086-5c4d-4692-ab27-39fd2c9e06e3", "name": "", "x": 38.56719749877506, "y": -122.49557460649763, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "02407b52-58c3-403c-9b5b-38695f435476", "name": "p1rdt5658-p1rdt7070x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "adff7086-5c4d-4692-ab27-39fd2c9e06e3"}}}}, {"uuid": "f380a6bd-42ac-4e94-852b-71eb43d521f4", "name": "", "x": 38.58873407774302, "y": -122.47343765394794, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c0843e99-e917-473c-bec7-ee0c3ddec601", "name": "p1rdt5017-p1rdt5200x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f380a6bd-42ac-4e94-852b-71eb43d521f4"}}}}, {"uuid": "21b5d83a-8c2e-4161-94a0-5316a279921c", "name": "", "x": 38.58804691015901, "y": -122.47096337199758, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "799ab435-c0a4-4515-8125-e8ca2fb7632d", "name": "p1rdt5200", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "21b5d83a-8c2e-4161-94a0-5316a279921c"}}}}, {"uuid": "44f794c1-8e6e-4411-a416-500797f57171", "name": "", "x": 38.599124013036686, "y": -122.46398556528375, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1b28595b-dcbe-4d1b-92c4-94acf370bb1f", "name": "p1rdt7576", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "44f794c1-8e6e-4411-a416-500797f57171"}}}}, {"uuid": "59b6cf59-ca9a-4f11-a6e9-118bc61c0fc8", "name": "", "x": 38.59899175164701, "y": -122.4633858496211, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4ce65512-7d5f-4514-b55c-1775e80dd94d", "name": "p1rdt8422", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59b6cf59-ca9a-4f11-a6e9-118bc61c0fc8"}}}}, {"uuid": "036c8efd-7db2-4870-82f2-3b943df50d82", "name": "", "x": 38.59980734698757, "y": -122.46809510052073, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75a31fa2-4df8-418a-a215-d0d450ced9a3", "name": "p1rdt7576-p1rdt8151xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "036c8efd-7db2-4870-82f2-3b943df50d82"}}}}, {"uuid": "5ddda534-1bae-4376-9940-923ffa5b0268", "name": "", "x": 38.59985029320267, "y": -122.46810315325398, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "df71ab4b-258c-4812-9537-6d425bacb468", "name": "p1rdt7576-p1rdt8151xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ddda534-1bae-4376-9940-923ffa5b0268"}}}}, {"uuid": "a77eb685-3722-4073-b5e1-fe119b376547", "name": "", "x": 38.59989292024887, "y": -122.46810581013978, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c951cf67-3297-407f-805c-55d9c03fb519", "name": "p1rdt7576-p1rdt8151x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a77eb685-3722-4073-b5e1-fe119b376547"}}}}, {"uuid": "63cc9012-4b26-4a85-b7cd-a17d2b412999", "name": "", "x": 38.59895094748302, "y": -122.46820159887727, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1613a53e-5194-4d26-b83b-475d9f02a32c", "name": "p1rdt8155", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "63cc9012-4b26-4a85-b7cd-a17d2b412999"}}}}, {"uuid": "e1bf1831-29fd-4c8c-a2d8-2caca097b732", "name": "", "x": 38.59895213180579, "y": -122.4682554984801, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b706c56-20f1-49ed-9cbe-0ec1491b83e0", "name": "p1rdt8149", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e1bf1831-29fd-4c8c-a2d8-2caca097b732"}}}}, {"uuid": "67b4a3bb-1120-4c1f-a699-5860c8fa90eb", "name": "", "x": 38.5924677842981, "y": -122.4635262800833, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8b423745-cc70-4c3a-adb0-f648170b4ab1", "name": "p1rdt8441", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "67b4a3bb-1120-4c1f-a699-5860c8fa90eb"}}}}, {"uuid": "a3ed93a5-c0ba-4cc1-ae05-71fcbd30574b", "name": "", "x": 38.59106375235361, "y": -122.46454322086704, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dac2cb8c-428b-49c4-8368-35608c050390", "name": "p1rdt5153-p1rdt8441xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a3ed93a5-c0ba-4cc1-ae05-71fcbd30574b"}}}}, {"uuid": "f0f6cd73-360a-4152-8fca-73066c995f16", "name": "", "x": 38.5891703292866, "y": -122.46631406470807, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dff898c1-a386-4219-9e8d-2d08b49f9098", "name": "p1rdt5153-p1rdt8441x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f0f6cd73-360a-4152-8fca-73066c995f16"}}}}, {"uuid": "0293898d-b01c-4468-ab99-40e98ee44971", "name": "", "x": 38.58821580644588, "y": -122.46709794144316, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eb8dae66-287a-4b8a-9cda-6ae02cb8f8a9", "name": "p1rdt5153", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0293898d-b01c-4468-ab99-40e98ee44971"}}}}, {"uuid": "94f325f3-6d2a-45bc-908f-e3cea41f7886", "name": "", "x": 38.59865977452597, "y": -122.46691737157991, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "78081763-07d2-4989-b492-e1c5178c4097", "name": "p1rdt8150", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "94f325f3-6d2a-45bc-908f-e3cea41f7886"}}}}, {"uuid": "fb3cd9d4-237f-4530-bd9a-6177b42a039b", "name": "", "x": 38.59382920785335, "y": -122.46428153625678, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "83b76782-be09-4733-a35c-6f3f26059a4d", "name": "p1rdt8150-p1rdt8441x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fb3cd9d4-237f-4530-bd9a-6177b42a039b"}}}}, {"uuid": "ba950250-6005-4961-ba68-6eea3fdd90dd", "name": "", "x": 38.59741418959317, "y": -122.46389890047125, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f2ef098d-d7e6-4530-a5cc-b6472ec9ffdc", "name": "p1rdt8150-p1rdt8442x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ba950250-6005-4961-ba68-6eea3fdd90dd"}}}}, {"uuid": "2202743d-a855-497a-87e1-851058c746c5", "name": "", "x": 38.597632581049226, "y": -122.46353019233372, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f6700763-e6dc-4626-ac2b-22985f0043be", "name": "p1rdt8442", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2202743d-a855-497a-87e1-851058c746c5"}}}}, {"uuid": "105d022a-345a-4dc1-add4-903d032442f7", "name": "", "x": 38.59878207629303, "y": -122.46742572315105, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b7280d1f-5ff9-45ee-9949-ecc70509a2a1", "name": "p1rdt8150-p1rdt8155x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "105d022a-345a-4dc1-add4-903d032442f7"}}}}, {"uuid": "358f69b2-02c9-48c0-8e3a-5a7b150a456d", "name": "", "x": 38.59899028699417, "y": -122.46961983252689, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9a30e197-897f-4516-b4e5-f70081e6f8c7", "name": "p1rdt8157", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "358f69b2-02c9-48c0-8e3a-5a7b150a456d"}}}}, {"uuid": "ae0a5a8f-0550-45d5-af05-1ee69e000ba1", "name": "", "x": 38.59975154279307, "y": -122.4680237146737, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b0a6628e-afc1-4daf-8a29-7626ac2aa5dd", "name": "p1rdt8151-p1rdt8155x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ae0a5a8f-0550-45d5-af05-1ee69e000ba1"}}}}, {"uuid": "2f1aa61f-7af2-40d3-b303-0f0bc8d88847", "name": "", "x": 38.64164273016234, "y": -122.45541248693772, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f903015c-95a7-4d6e-b2a5-e9705c050c6e", "name": "p1rdt5483", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2f1aa61f-7af2-40d3-b303-0f0bc8d88847"}}}}, {"uuid": "273a046e-c5ce-4125-9e31-028bb8292c8c", "name": "", "x": 38.64024304330955, "y": -122.45644844030662, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d29d8b74-a24d-4474-9752-c1ffa1aa7f7c", "name": "p1rdt5481", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "273a046e-c5ce-4125-9e31-028bb8292c8c"}}}}, {"uuid": "68c9a036-808f-4fad-8506-4a7896b8996d", "name": "", "x": 38.641756332042426, "y": -122.45557875811565, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2568f11c-8a37-4a55-8bce-9f0d56ac386a", "name": "p1rdt5480", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "68c9a036-808f-4fad-8506-4a7896b8996d"}}}}, {"uuid": "6a9bbaf7-c083-4fc4-802d-91e2d4b0f4db", "name": "", "x": 38.642142868875986, "y": -122.45608936956037, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a7d7f462-1ab5-4fd8-baaa-7e576eead5c7", "name": "p1rdt5477", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a9bbaf7-c083-4fc4-802d-91e2d4b0f4db"}}}}, {"uuid": "33ece59e-3a10-4c95-950d-ecedcc29e1d0", "name": "", "x": 38.64281235221596, "y": -122.45532194437911, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "df1d5615-4a0b-4041-8940-f13de9f7036a", "name": "p1rdt5477-p1rdt7201x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "33ece59e-3a10-4c95-950d-ecedcc29e1d0"}}}}, {"uuid": "000a5153-68d8-45da-89ab-617a8cd6cb36", "name": "", "x": 38.64321277078752, "y": -122.4548323247065, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f64ed4a2-6afb-447c-8c6b-15935e050a6d", "name": "p1rdt7201", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "000a5153-68d8-45da-89ab-617a8cd6cb36"}}}}, {"uuid": "f7c432d6-1633-4358-86dc-895b71dd2c40", "name": "", "x": 38.642219786001824, "y": -122.45774171841002, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a8c3f7f-b9be-4c5e-b6f0-8f2fc18935fa", "name": "p1rdt5472", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f7c432d6-1633-4358-86dc-895b71dd2c40"}}}}, {"uuid": "d7d5b93b-1a5a-4f71-95e8-3f2b1a9a411b", "name": "", "x": 38.64221051314406, "y": -122.45768209005053, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "595463a5-2019-4c94-b72d-c824c2aef347", "name": "p1rdt5472-p1rdt5477x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d7d5b93b-1a5a-4f71-95e8-3f2b1a9a411b"}}}}, {"uuid": "0d4453f9-bd03-4074-82f5-92e6944000d8", "name": "", "x": 38.63937777553964, "y": -122.46168143344667, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d69527e6-70b6-43e2-8b9e-7c8570ad5ddf", "name": "p1rdt5472-p1rdt5476x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0d4453f9-bd03-4074-82f5-92e6944000d8"}}}}, {"uuid": "7c7cf273-8a35-4f1b-b0df-652e02e8d7c4", "name": "", "x": 38.634273490971374, "y": -122.45107406346328, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "02ea9067-6a2a-48b6-b5f1-10992b9fbd77", "name": "p1rdt7704", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7c7cf273-8a35-4f1b-b0df-652e02e8d7c4"}}}}, {"uuid": "7f99c451-b1c2-40d3-9f37-2911f14e0083", "name": "", "x": 38.633218038007875, "y": -122.44832866649233, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f633393e-4d67-4646-838b-14f25641b426", "name": "p1rdt7704-p1rdt9266x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7f99c451-b1c2-40d3-9f37-2911f14e0083"}}}}, {"uuid": "983285a7-75f5-4a80-b562-57390f24885f", "name": "", "x": 38.63351410324478, "y": -122.44695962318366, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6fbb2bd0-d109-4248-85f3-266fe479677f", "name": "p1rdt9266", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "983285a7-75f5-4a80-b562-57390f24885f"}}}}, {"uuid": "91a6b8b3-39c6-43fb-9476-f82b581450b9", "name": "", "x": 38.63645110302719, "y": -122.45301866057562, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4462b9c6-748f-48e9-9ff9-7f20a06cf456", "name": "p1rdt7712", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "91a6b8b3-39c6-43fb-9476-f82b581450b9"}}}}, {"uuid": "c6e2115c-5e23-404f-8d02-cfc7459bceb4", "name": "", "x": 38.63434015287993, "y": -122.45255214689988, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "048e2bab-67f2-4975-81a1-bbc9f2f9cd88", "name": "p1rdt7718", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c6e2115c-5e23-404f-8d02-cfc7459bceb4"}}}}, {"uuid": "b8a68cb6-346c-42b7-abe2-6eed14ab959d", "name": "", "x": 38.636858070821944, "y": -122.45332579295936, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "74968ebc-53c5-4fc6-8172-3ffa9dea7683", "name": "p1rdt7701", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b8a68cb6-346c-42b7-abe2-6eed14ab959d"}}}}, {"uuid": "a9d37e1d-5173-4635-a52b-7cf55ef8c650", "name": "", "x": 38.63763391930191, "y": -122.4535037389147, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ec849ee4-3d69-46a9-9a2a-242a3943e46c", "name": "p1rdt7699", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a9d37e1d-5173-4635-a52b-7cf55ef8c650"}}}}, {"uuid": "4260e8f1-7798-4deb-9e31-1fca3abf1a52", "name": "", "x": 38.63933239277819, "y": -122.45585430535672, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3cfb3a23-3a93-4d89-8b70-e4730ebbce1a", "name": "p1rdt5485", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4260e8f1-7798-4deb-9e31-1fca3abf1a52"}}}}, {"uuid": "bc656b69-36a4-43ff-b71d-c180a2f08d8e", "name": "", "x": 38.638463291461264, "y": -122.45417138292237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "890cd47a-994b-4dca-8d59-25164f04c927", "name": "p1rdt5485-p1rdt7699x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bc656b69-36a4-43ff-b71d-c180a2f08d8e"}}}}, {"uuid": "6a726f29-4815-4b7e-9cdd-3ba9cab41478", "name": "", "x": 38.639561691754864, "y": -122.45649160162748, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2b9e57e0-6dc8-4831-ac7d-36f8608b7a8d", "name": "p1rdt5475", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a726f29-4815-4b7e-9cdd-3ba9cab41478"}}}}, {"uuid": "ea984b77-b138-4d35-84e2-6f5e1b3be68a", "name": "", "x": 38.63942177536906, "y": -122.46162651516015, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ae343ca3-3337-4528-b117-38a51e6d023f", "name": "p1rdt5475-p1rdt5476x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea984b77-b138-4d35-84e2-6f5e1b3be68a"}}}}, {"uuid": "c6a41314-ff2d-43b3-b5cc-6e2a28deffa6", "name": "", "x": 38.63947133387594, "y": -122.46167250985621, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4c977e6c-43f0-4d7e-b19f-82f0de97dab2", "name": "p1rdt5476-p1rdt5478x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c6a41314-ff2d-43b3-b5cc-6e2a28deffa6"}}}}, {"uuid": "4979c1e5-b450-4e65-96a4-18e6717e9de6", "name": "", "x": 38.637232713702204, "y": -122.4583095586275, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9a97491e-2c98-4584-9b74-5593f17faeda", "name": "p1rdt5478", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4979c1e5-b450-4e65-96a4-18e6717e9de6"}}}}, {"uuid": "2eb92f32-3756-41cd-b0da-65a66c24a381", "name": "", "x": 38.629275148712736, "y": -122.45440586693407, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "96399e51-1243-4e7f-ae3a-5e2c67123aae", "name": "p1rdt6848", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2eb92f32-3756-41cd-b0da-65a66c24a381"}}}}, {"uuid": "02d00be7-cb00-4607-bd85-777ce7f0a710", "name": "", "x": 38.62915793743979, "y": -122.45307010539497, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2b764d22-debb-4d88-8221-ff79307e609f", "name": "p1rdt6848-p1rdt9264x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "02d00be7-cb00-4607-bd85-777ce7f0a710"}}}}, {"uuid": "2777bf8f-fb4b-4519-88c5-7462abde8f9a", "name": "", "x": 38.62929755153899, "y": -122.45269743640755, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6bdf3994-bb0c-44f4-b1ea-ab29e73bd39c", "name": "p1rdt9264", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2777bf8f-fb4b-4519-88c5-7462abde8f9a"}}}}, {"uuid": "d6f76c08-aa28-4f37-96e7-37ad79f4b724", "name": "", "x": 38.63204510201893, "y": -122.46437683506844, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3e92b102-eaee-41cc-a2fc-c6c4b3bfb58b", "name": "p1rdt6847", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d6f76c08-aa28-4f37-96e7-37ad79f4b724"}}}}, {"uuid": "597d61bf-b7a2-48d5-9bb2-6befc99d855a", "name": "", "x": 38.637551036439916, "y": -122.4658407872937, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be9350ab-7ad2-4a89-a374-94bf69588d7f", "name": "p1rdt6847-p1rdt7624x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "597d61bf-b7a2-48d5-9bb2-6befc99d855a"}}}}, {"uuid": "854252b7-a9be-439b-b237-47caad78812a", "name": "", "x": 38.63745413036962, "y": -122.41088901665674, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4d6c5b78-35c4-475a-8837-776dea236c95", "name": "p1rdt6348", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "854252b7-a9be-439b-b237-47caad78812a"}}}}, {"uuid": "601cbd90-802e-4147-93e4-1a0dee2ea031", "name": "", "x": 38.63621334895868, "y": -122.41023104176281, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c935f1c0-e36c-407d-a2e8-4181c4b0733e", "name": "p1rdt6350", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "601cbd90-802e-4147-93e4-1a0dee2ea031"}}}}, {"uuid": "e5e50d5c-d080-4d8d-b9cf-869a003ee1f5", "name": "", "x": 38.635943272929005, "y": -122.41464349224492, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "40280da5-767c-4610-b6a8-ff411e1c33e8", "name": "p1rdt6345", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e5e50d5c-d080-4d8d-b9cf-869a003ee1f5"}}}}, {"uuid": "2fb72ea7-b013-493a-940f-9e1e8a973dd2", "name": "", "x": 38.637135599334236, "y": -122.41985198242058, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1bdfc1ac-98a4-43dd-bb2c-837d0a2c15f9", "name": "p1rdt6356", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2fb72ea7-b013-493a-940f-9e1e8a973dd2"}}}}, {"uuid": "65123f8f-99b8-4bc5-a743-806f7f6963d0", "name": "", "x": 38.63428208141972, "y": -122.41685332058216, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8e51e0d9-24b6-40ac-859a-51ea74c93e76", "name": "p1rdt6353", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65123f8f-99b8-4bc5-a743-806f7f6963d0"}}}}, {"uuid": "ad2a38c2-3edd-4b63-9187-242b9e02e7b1", "name": "", "x": 38.637037161169054, "y": -122.41998840936154, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2040b1a2-85bc-405a-9dab-138561b5e3ac", "name": "p1rdt6354-p1rdt6356x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ad2a38c2-3edd-4b63-9187-242b9e02e7b1"}}}}, {"uuid": "3be1ed3b-9da6-42c9-8228-52e392d086e4", "name": "", "x": 38.6365030259924, "y": -122.42074352091329, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1a05e7c9-4bff-46fd-b356-8120b481b053", "name": "p1rdt6354", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3be1ed3b-9da6-42c9-8228-52e392d086e4"}}}}, {"uuid": "150904ad-1522-4a28-9697-1c2bfb036cd7", "name": "", "x": 38.63888731873398, "y": -122.42664972566449, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c7166849-6ecd-4270-bf52-d0579838336a", "name": "p1rdt6347", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "150904ad-1522-4a28-9697-1c2bfb036cd7"}}}}, {"uuid": "4d009f86-5794-4639-91c0-2a5ac3e6cdce", "name": "", "x": 38.63046949482658, "y": -122.42586839274048, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6e36f1f1-6993-46b0-bafa-9530fd1652ef", "name": "p1rdt7605", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d009f86-5794-4639-91c0-2a5ac3e6cdce"}}}}, {"uuid": "4ae5dbc6-e0bc-49e8-b304-6f7ac9362bd2", "name": "", "x": 38.63106444152601, "y": -122.42668905474402, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f95e5fa5-a84c-42a4-b519-8d344e816ecd", "name": "p1rdt7598", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ae5dbc6-e0bc-49e8-b304-6f7ac9362bd2"}}}}, {"uuid": "a5f8fa10-b048-48a1-860f-3b120eb360fa", "name": "", "x": 38.632704736208574, "y": -122.42169322012252, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5f9809eb-41e0-40a8-b43a-93556f767f68", "name": "p1rdt7589", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a5f8fa10-b048-48a1-860f-3b120eb360fa"}}}}, {"uuid": "0ce8819e-f17b-461b-8c62-5afbaabea831", "name": "", "x": 38.62803766509506, "y": -122.4206605617657, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3410d88a-3e9c-427e-a79e-5c602455ed1d", "name": "p1rdt7612", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0ce8819e-f17b-461b-8c62-5afbaabea831"}}}}, {"uuid": "5d59340d-16c5-4b89-8091-5c32f734632c", "name": "", "x": 38.64794018977543, "y": -122.44170447330542, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6163371c-55ef-4900-a3ef-2e4e8fc2894a", "name": "p1rdt6347-p1rdt8470x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5d59340d-16c5-4b89-8091-5c32f734632c"}}}}, {"uuid": "1965718d-a8b3-400b-a48b-dcee8657a6ac", "name": "", "x": 38.65468732876317, "y": -122.39725551743196, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "769c14db-ac3f-438d-9f7d-c7eb2d3074b5", "name": "p1rdt5653", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1965718d-a8b3-400b-a48b-dcee8657a6ac"}}}}, {"uuid": "29c6209f-ca61-4fb8-987f-c2da46ad0d9b", "name": "", "x": 38.65539216836069, "y": -122.39642965058673, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "98f2c16a-cdbd-49a3-b60d-4be6e9158480", "name": "p1rdt5218-p1rdt5653x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "29c6209f-ca61-4fb8-987f-c2da46ad0d9b"}}}}, {"uuid": "9ccf40bd-2c7a-40e1-a90b-72438700a78e", "name": "", "x": 38.65638553565669, "y": -122.3958356267157, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9dda7f7c-3b21-46a0-88a3-2b7f028b7772", "name": "p1rdt5218", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9ccf40bd-2c7a-40e1-a90b-72438700a78e"}}}}, {"uuid": "c08bee5c-777a-4666-8eec-9b3dd673bfbc", "name": "", "x": 38.649267204221246, "y": -122.40284351830519, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "58c6d858-d457-4fe6-a45b-b9b2b73cad8c", "name": "p1rdt5195", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c08bee5c-777a-4666-8eec-9b3dd673bfbc"}}}}, {"uuid": "f1105e91-4b0f-4530-adf0-ed1cb33735f5", "name": "", "x": 38.649760224171196, "y": -122.40177465588245, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fbc486eb-4f08-4602-a101-1298d4a46b32", "name": "p1rdt5195_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f1105e91-4b0f-4530-adf0-ed1cb33735f5"}}}}, {"uuid": "49651b45-fc27-43ca-af8d-9789a4a6004a", "name": "", "x": 38.648493079669315, "y": -122.39370880076001, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3741c9d4-d03a-4b2f-be57-52a8977351ad", "name": "p1rdt6995", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "49651b45-fc27-43ca-af8d-9789a4a6004a"}}}}, {"uuid": "4b0305c0-1037-4ef4-949a-597397ef270e", "name": "", "x": 38.648911595375175, "y": -122.39447297420028, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2d4d11a9-8de3-4dbe-8974-6005ed40f363", "name": "p1rdt6995-p1rdt7015x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4b0305c0-1037-4ef4-949a-597397ef270e"}}}}, {"uuid": "a7bc3009-8e8d-4e17-b616-c76252626a6c", "name": "", "x": 38.64914243697819, "y": -122.39455192500522, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6278a0d-f5d3-4b11-aee9-3bb23f9954a8", "name": "p1rdt7015", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a7bc3009-8e8d-4e17-b616-c76252626a6c"}}}}, {"uuid": "abb1e08a-855e-4897-a673-308816a942cc", "name": "", "x": 38.65509732869403, "y": -122.34387202316023, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6c0d417e-c787-4b0a-a39e-b19ef274b36b", "name": "p1rdt16638", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "abb1e08a-855e-4897-a673-308816a942cc"}}}}, {"uuid": "8297b428-5b23-4152-ab9c-87c2979a4b24", "name": "", "x": 38.656349996019614, "y": -122.34286866169235, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c2d0eb0b-bbb6-4b3e-bdc6-4c8a0e7d466f", "name": "p1rdt16725", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8297b428-5b23-4152-ab9c-87c2979a4b24"}}}}, {"uuid": "9a600806-0174-49eb-91db-fe69ef61fe1b", "name": "", "x": 38.65481285259022, "y": -122.34567144468134, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ddb8e50b-2619-4e74-aee6-84dc4e11389e", "name": "p1rdt16638-p1rdt6995x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9a600806-0174-49eb-91db-fe69ef61fe1b"}}}}, {"uuid": "39e782d2-a807-49ed-80d0-94565d915d21", "name": "", "x": 38.649657570740004, "y": -122.40108599864732, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9056795d-5c81-4fb9-96bc-51d63b32b187", "name": "p1rdt5195-p1rdt6995x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "39e782d2-a807-49ed-80d0-94565d915d21"}}}}, {"uuid": "cd10cffe-a98a-4acd-b67f-fc34e733b7f8", "name": "", "x": 38.647538844802774, "y": -122.40874594362695, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "227d848c-cddc-4561-996b-f8f7a60a5a89", "name": "p1rdt5195-p1rdt5202xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cd10cffe-a98a-4acd-b67f-fc34e733b7f8"}}}}, {"uuid": "089f2e83-3db8-4d79-9106-f2ded1bf5cc7", "name": "", "x": 38.64780415928914, "y": -122.40698510373619, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "43e1b69a-c6dd-447e-82d9-921998de9837", "name": "p1rdt5195-p1rdt5202xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "089f2e83-3db8-4d79-9106-f2ded1bf5cc7"}}}}, {"uuid": "26852e48-00b2-4987-9615-bb92ddc4d19d", "name": "", "x": 38.64819471408059, "y": -122.40580973948633, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8e2f2704-4dee-4c78-b199-256b907156f3", "name": "p1rdt5195-p1rdt5202x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "26852e48-00b2-4987-9615-bb92ddc4d19d"}}}}, {"uuid": "5ce2d535-677f-4124-97e4-ce80c6f3a10b", "name": "", "x": 38.64756484598567, "y": -122.4087885476493, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "97e4f179-9d60-4183-8326-eb0ab98a53eb", "name": "p1rdt5202", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ce2d535-677f-4124-97e4-ce80c6f3a10b"}}}}, {"uuid": "2e5194ca-81e3-4cce-b22d-e2f1ba68986d", "name": "", "x": 38.646212863621486, "y": -122.4077336633597, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "17fedb14-6008-43fd-b7e9-342a113f27a6", "name": "p1rdt5202-p1rdt5206x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2e5194ca-81e3-4cce-b22d-e2f1ba68986d"}}}}, {"uuid": "87956ea9-4e14-4028-a086-a242d4767471", "name": "", "x": 38.64569758673296, "y": -122.40751541256846, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2ed081eb-6b56-43b8-9cf8-e7ffdd8222f2", "name": "p1rdt5206", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "87956ea9-4e14-4028-a086-a242d4767471"}}}}, {"uuid": "f78d39fc-8180-40e0-b698-65cd5bfa44c7", "name": "", "x": 38.65086417573999, "y": -122.42606190704704, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a21680f1-33a7-44e1-9293-98c6861ba2a5", "name": "p1rdt7268", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f78d39fc-8180-40e0-b698-65cd5bfa44c7"}}}}, {"uuid": "70e977d3-80cc-4570-8493-adcde3e97600", "name": "", "x": 38.64877414711051, "y": -122.41168870941135, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6e61d2f-f75e-4335-aec9-4722942be9f1", "name": "p1rdt5202-p1rdt7268x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "70e977d3-80cc-4570-8493-adcde3e97600"}}}}, {"uuid": "72701ad2-e31a-4773-8b69-a2d3ae194283", "name": "", "x": 38.64212986886906, "y": -122.42144512012567, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "88cc1382-6b14-4500-8a21-662fce6a0c0b", "name": "p1rdt6355", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "72701ad2-e31a-4773-8b69-a2d3ae194283"}}}}, {"uuid": "c0ec56eb-72c0-4ca6-8556-375e1b1f7cc1", "name": "", "x": 38.64194634219145, "y": -122.4207801394437, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3c1edcfa-e0e4-4493-a9bb-e6033185ce67", "name": "p1rdt6349", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c0ec56eb-72c0-4ca6-8556-375e1b1f7cc1"}}}}, {"uuid": "bf893988-405e-4ab8-b905-b745f43a9a00", "name": "", "x": 38.64540330832493, "y": -122.421204010774, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eeab7dfa-540c-4275-b159-f6ac4d1350f9", "name": "p1rdt7224", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bf893988-405e-4ab8-b905-b745f43a9a00"}}}}, {"uuid": "a6dbd015-0a15-482b-9236-103a366e1112", "name": "", "x": 38.64637376282259, "y": -122.41881749796097, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b0fef9b3-a4bd-421c-8a54-cbf6f44c460d", "name": "p1rdt7618", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a6dbd015-0a15-482b-9236-103a366e1112"}}}}, {"uuid": "4c5c6dcd-63b8-41a2-8093-8cca2d72aeea", "name": "", "x": 38.649069267013274, "y": -122.42574072103456, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "22978d10-c9dc-4c84-8025-5749c730daa6", "name": "p1rdt7224-p1rdt7268x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c5c6dcd-63b8-41a2-8093-8cca2d72aeea"}}}}, {"uuid": "c46f4e0b-dc3c-4a3f-be3f-38e560bf6190", "name": "", "x": 38.64786537466463, "y": -122.44168489363972, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6225b33-2abc-4f77-9d65-459794f56353", "name": "p1rdt7268-p1rdt8470x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c46f4e0b-dc3c-4a3f-be3f-38e560bf6190"}}}}, {"uuid": "927a4063-4d22-46e6-ac4f-c015458ef7d8", "name": "", "x": 38.65324099971405, "y": -122.46490061193234, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "97198258-8ba3-4950-8747-3241c6a4fcee", "name": "p1rdt7790", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "927a4063-4d22-46e6-ac4f-c015458ef7d8"}}}}, {"uuid": "8f7b0799-74df-4334-8e29-dd46150745c8", "name": "", "x": 38.65493103663836, "y": -122.46522487253812, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "62078787-3ae2-47b3-8f67-8e89e110c8be", "name": "p1rdt7735", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8f7b0799-74df-4334-8e29-dd46150745c8"}}}}, {"uuid": "d818e1c1-0ba9-41c1-a9de-6fd225be8ae4", "name": "", "x": 38.651340821800964, "y": -122.4634244039528, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "15a7847f-aa96-4206-b4c6-422802f4e0a6", "name": "p1rdt7790-p1rdt9090x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d818e1c1-0ba9-41c1-a9de-6fd225be8ae4"}}}}, {"uuid": "fb91d7f3-340f-4966-b7e0-d358967a4734", "name": "", "x": 38.65962472553894, "y": -122.44176628998517, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "26613f51-86bf-4ae1-86c0-f23e48cf606e", "name": "p1rdt8911", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fb91d7f3-340f-4966-b7e0-d358967a4734"}}}}, {"uuid": "1bab182c-4582-47c6-8d17-29842e513a82", "name": "", "x": 38.65931212124818, "y": -122.44176119733557, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7bc7d623-3ca7-4c4e-b11c-f373e90d06b6", "name": "p1rdt8911-p1rdt9384x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1bab182c-4582-47c6-8d17-29842e513a82"}}}}, {"uuid": "b5c3aa09-2214-445c-bfa5-3d3f96eb953f", "name": "", "x": 38.65864576551388, "y": -122.44127613204223, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6eb9c7a5-5ab1-4d9b-a59e-538b68ad0bb9", "name": "p1rdt9384", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b5c3aa09-2214-445c-bfa5-3d3f96eb953f"}}}}, {"uuid": "92919a40-4844-490d-a018-5e9680adcac0", "name": "", "x": 38.660983681991716, "y": -122.44208551181131, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "924fc042-6ddc-484b-b09f-c65b35817d25", "name": "p1rdt8905", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "92919a40-4844-490d-a018-5e9680adcac0"}}}}, {"uuid": "b8032e4e-ca80-4e94-918c-c9de73f29a0c", "name": "", "x": 38.66020225533911, "y": -122.44026057728638, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "adcc33f8-72a3-434c-a021-6c5973713a91", "name": "p1rdt8916", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b8032e4e-ca80-4e94-918c-c9de73f29a0c"}}}}, {"uuid": "1df05fd9-2ce1-423d-a9c2-c03c77b85391", "name": "", "x": 38.66014117583918, "y": -122.43986982074505, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5584edfb-c31e-4e1d-87d3-b8161a59b15b", "name": "p1rdt8904-p1rdt8916x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1df05fd9-2ce1-423d-a9c2-c03c77b85391"}}}}, {"uuid": "822ecf5e-9bf8-48d7-ae80-9241a08d5eef", "name": "", "x": 38.659870600443035, "y": -122.43853470846769, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2edd17c2-6dfb-4f86-8998-b90a99755e96", "name": "p1rdt8904", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "822ecf5e-9bf8-48d7-ae80-9241a08d5eef"}}}}, {"uuid": "cfdaa503-512b-4f4b-b7d2-25964bd60174", "name": "", "x": 38.66173047874001, "y": -122.44241135887862, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "361385c6-bb6d-4bbc-ab7d-4a5774e03d82", "name": "p1rdt8915", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cfdaa503-512b-4f4b-b7d2-25964bd60174"}}}}, {"uuid": "e09dc659-3e15-4f79-91c9-b52d623601ea", "name": "", "x": 38.66056980039024, "y": -122.44983541740483, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25a9ec20-35b9-4262-a02d-cafa63e5ee42", "name": "p1rdt6574", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e09dc659-3e15-4f79-91c9-b52d623601ea"}}}}, {"uuid": "17b20f9d-2e67-45af-a1f1-f14bdf5b6629", "name": "", "x": 38.66134287929267, "y": -122.44811296163041, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c9ef9958-5d9e-4907-91cd-4c5d099daaf1", "name": "p1rdt6574-p1rdt8915x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "17b20f9d-2e67-45af-a1f1-f14bdf5b6629"}}}}, {"uuid": "c909eedd-a3ad-4f87-a346-40647f90f3ca", "name": "", "x": 38.65937095205677, "y": -122.45169503023163, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "599c6ed9-5ff7-4c97-a469-adceecaaf902", "name": "p1rdt6581", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c909eedd-a3ad-4f87-a346-40647f90f3ca"}}}}, {"uuid": "169793d1-b20d-4e43-a918-a31b39feffe4", "name": "", "x": 38.658524104486, "y": -122.45387735426675, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6114624f-81c8-4d9c-8f9a-3ab73158596e", "name": "p1rdt6581-p1rdt9084x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "169793d1-b20d-4e43-a918-a31b39feffe4"}}}}, {"uuid": "32d60b45-d56c-403d-99e5-72dbc6f6ee64", "name": "", "x": 38.65932938830671, "y": -122.45365277312096, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b2ce5116-c4f0-4ac7-a34f-3ba44c99d04b", "name": "p1rdt9076", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "32d60b45-d56c-403d-99e5-72dbc6f6ee64"}}}}, {"uuid": "ed78c300-b738-4256-82ac-69932d19430e", "name": "", "x": 38.6598966989538, "y": -122.45427706074868, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c29179f3-0b4e-449c-8562-a8fcb675be6c", "name": "p1rdt9093", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ed78c300-b738-4256-82ac-69932d19430e"}}}}, {"uuid": "67e13266-9238-4cad-9947-2673df4847a6", "name": "", "x": 38.658584295641674, "y": -122.4538145255183, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "12b4dc99-fe50-457c-90aa-48a2fb19ebf1", "name": "p1rdt9076-p1rdt9084x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "67e13266-9238-4cad-9947-2673df4847a6"}}}}, {"uuid": "783adc37-8f14-4fc0-9882-7ff2167cccc1", "name": "", "x": 38.65080476587911, "y": -122.46154361413883, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "563c6bb3-d8ed-4fce-ad66-3892426248df", "name": "p1rdt9091", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "783adc37-8f14-4fc0-9882-7ff2167cccc1"}}}}, {"uuid": "f8ebc8aa-10ca-4c4b-a76e-7b55f47da7af", "name": "", "x": 38.65078478496911, "y": -122.46111855767518, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7fcdf409-885c-4c95-834e-988842ed3f5c", "name": "p1rdt9085", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f8ebc8aa-10ca-4c4b-a76e-7b55f47da7af"}}}}, {"uuid": "20bb0b23-1255-4362-8a41-c2cb5865a639", "name": "", "x": 38.6513283597693, "y": -122.46332611842509, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf719d10-8168-4d80-894e-1b1516f033e8", "name": "p1rdt9090-p1rdt9091x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "20bb0b23-1255-4362-8a41-c2cb5865a639"}}}}, {"uuid": "9969e473-9935-40da-9183-2c6da735131b", "name": "", "x": 38.64979039983577, "y": -122.4656039969192, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a5f6a2ec-3ddd-4ba7-9c55-88b4d82e7735", "name": "p1rdt9469-p1rdt9470x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9969e473-9935-40da-9183-2c6da735131b"}}}}, {"uuid": "6263920c-9fc3-4b2e-a546-abbddd42605f", "name": "", "x": 38.65049921056124, "y": -122.46639198488886, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "acf91e46-ba32-44c3-a829-14c80a693d7d", "name": "p1rdt9470", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6263920c-9fc3-4b2e-a546-abbddd42605f"}}}}, {"uuid": "0a73ebe0-b63d-458f-a694-bef5e5e35908", "name": "", "x": 38.62473134403656, "y": -122.446341336382, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "431b672b-cb45-4294-b1f9-1d63f4efc8db", "name": "p1rdt5184", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a73ebe0-b63d-458f-a694-bef5e5e35908"}}}}, {"uuid": "40171f66-03ca-44d5-a7d9-dd81cd1d77d0", "name": "", "x": 38.62489829777773, "y": -122.44603739457851, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ceb58d66-3cb3-416d-aedf-f4949432eb37", "name": "p1rdt5140-p1rdt5184x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "40171f66-03ca-44d5-a7d9-dd81cd1d77d0"}}}}, {"uuid": "3c7c92ef-f3c4-4b07-a237-27029a3a135b", "name": "", "x": 38.625549640330384, "y": -122.44525871373254, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4b0fd055-d0ac-4678-a8e5-679e12741736", "name": "p1rdt5140", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3c7c92ef-f3c4-4b07-a237-27029a3a135b"}}}}, {"uuid": "ad9b4b7a-0931-459e-98b2-2be8e2026ce0", "name": "", "x": 38.62488841554401, "y": -122.44776290196933, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "50332aed-ecfd-465a-977e-c24ed6462860", "name": "p1rdt5154", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ad9b4b7a-0931-459e-98b2-2be8e2026ce0"}}}}, {"uuid": "8e9f56d8-7fca-4f4e-ae86-e65be9cb8c4f", "name": "", "x": 38.62229054802191, "y": -122.44975245942024, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d579047b-82f6-49bf-bd7b-28c818d44bb3", "name": "p1rdt5142", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8e9f56d8-7fca-4f4e-ae86-e65be9cb8c4f"}}}}, {"uuid": "d8684006-5b25-49fb-a434-cfc2f1c5dec1", "name": "", "x": 38.62220258438888, "y": -122.44622230651564, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c6316fa2-dd57-46d4-89c0-f11dd675d686", "name": "p1rdt5180", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d8684006-5b25-49fb-a434-cfc2f1c5dec1"}}}}, {"uuid": "0c16fccb-d717-44aa-9f38-45a6246e6956", "name": "", "x": 38.62380545487311, "y": -122.4562212466049, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b48f78d-1092-4536-bfb3-029da6a70dff", "name": "p1rdt8414", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0c16fccb-d717-44aa-9f38-45a6246e6956"}}}}, {"uuid": "1c64bcc6-45c2-4d20-8bf9-0e11de4c7265", "name": "", "x": 38.623626833691524, "y": -122.455467102224, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "50f71b3d-83ce-4526-8057-4a38042b7295", "name": "p1rdt5142-p1rdt8414x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1c64bcc6-45c2-4d20-8bf9-0e11de4c7265"}}}}, {"uuid": "0b35d36d-70fc-40d5-914c-1a06b686e5a9", "name": "", "x": 38.62564005248976, "y": -122.46602311753331, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "42929633-40d4-4e13-a0aa-a7682f328226", "name": "p1rdt6409", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0b35d36d-70fc-40d5-914c-1a06b686e5a9"}}}}, {"uuid": "319a6f16-24d3-4b77-b1e8-7f7402459352", "name": "", "x": 38.62467409594971, "y": -122.4578141983919, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c8648275-54c9-48e3-82e0-33119313924d", "name": "p1rdt6409-p1rdt8414x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "319a6f16-24d3-4b77-b1e8-7f7402459352"}}}}, {"uuid": "1e5d5efe-22c3-4d18-9fba-2f30ab355a68", "name": "", "x": 38.62028911584838, "y": -122.47934854754749, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f750e531-5ade-40a9-9bb0-042220ce9807", "name": "p1rdt9413", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1e5d5efe-22c3-4d18-9fba-2f30ab355a68"}}}}, {"uuid": "c9ef1203-c178-47da-b18f-e0dc8a149ce5", "name": "", "x": 38.607806368453346, "y": -122.45767322666612, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f9b94106-b7c5-4ce9-9c19-053487848c2a", "name": "p1rdt7570", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c9ef1203-c178-47da-b18f-e0dc8a149ce5"}}}}, {"uuid": "1ea6e363-b354-4950-a115-36df79ac7e00", "name": "", "x": 38.60650861543276, "y": -122.45746126944624, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fd487832-bc77-406f-a995-4b099fad7c64", "name": "p1rdt7574", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1ea6e363-b354-4950-a115-36df79ac7e00"}}}}, {"uuid": "a90235cd-9b37-4856-b9de-bb34434bd0c2", "name": "", "x": 38.61094163932077, "y": -122.45877502518786, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "08d4c459-5bc5-4cad-8e74-613c4a08cb35", "name": "p1rdt6275", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a90235cd-9b37-4856-b9de-bb34434bd0c2"}}}}, {"uuid": "2d935bfb-e43c-45ee-b5df-0d97d91514f4", "name": "", "x": 38.6129133935745, "y": -122.45941441983003, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3cf36152-b3af-49f7-b693-5d465db1f283", "name": "p1rdt6270", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2d935bfb-e43c-45ee-b5df-0d97d91514f4"}}}}, {"uuid": "dfb10ac3-d01d-4ffb-a16b-d27afac7c0cb", "name": "", "x": 38.61549898247823, "y": -122.4595395605965, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b5ef97a6-6c60-46eb-acce-6469b273658a", "name": "p1rdt6269", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dfb10ac3-d01d-4ffb-a16b-d27afac7c0cb"}}}}, {"uuid": "7ef54c91-36ce-43c7-8b71-0385b3d8dc94", "name": "", "x": 38.617305618456946, "y": -122.4643619588085, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60829dab-c129-4017-961a-81435d8afa93", "name": "p1rdt8405", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7ef54c91-36ce-43c7-8b71-0385b3d8dc94"}}}}, {"uuid": "f73d9123-c351-479d-ba0d-bfd88fcaeac1", "name": "", "x": 38.62031463672319, "y": -122.47930548988975, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16ecb938-cd0c-4be5-a915-be0d84d351f2", "name": "p1rdt8405-p1rdt9413x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f73d9123-c351-479d-ba0d-bfd88fcaeac1"}}}}, {"uuid": "1031a2c7-4eb4-4229-8c5a-3ba72e4b2638", "name": "", "x": 38.574957799581, "y": -122.51876395636346, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d25f8d60-8aa7-4975-96dc-eba7696fa8ae", "name": "p1rdt9314", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1031a2c7-4eb4-4229-8c5a-3ba72e4b2638"}}}}, {"uuid": "43aaaf9a-7585-41cb-8661-2358b2f561e5", "name": "", "x": 38.57551466426878, "y": -122.51886483712937, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d39c608-5688-4e22-8ac4-96b896265274", "name": "p1rdt6518", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "43aaaf9a-7585-41cb-8661-2358b2f561e5"}}}}, {"uuid": "31845f68-2f99-480e-95bc-602b2a660cb5", "name": "", "x": 38.57472269246426, "y": -122.51786257188046, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d9b006c3-79f8-4a27-b76a-d1b458ff2a21", "name": "p1rdt9479", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "31845f68-2f99-480e-95bc-602b2a660cb5"}}}}, {"uuid": "635efc5b-e76d-40a8-b026-2e8350de069e", "name": "", "x": 38.57508507780314, "y": -122.51765748560604, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9707f264-8f82-4483-8337-6c89d709faf7", "name": "p1rdt6539", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "635efc5b-e76d-40a8-b026-2e8350de069e"}}}}, {"uuid": "d5df494f-b6e9-4370-9ff0-795e3592612e", "name": "", "x": 38.575354576929136, "y": -122.51744904257968, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0db3e719-4dba-4b45-af70-c35546c19eb4", "name": "p1rdt6507", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d5df494f-b6e9-4370-9ff0-795e3592612e"}}}}, {"uuid": "6f46c81f-1ceb-4611-9652-4535d88f4fc6", "name": "", "x": 38.577519567449535, "y": -122.51578138154942, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "40ec7437-80f0-49e8-806a-c696b1402713", "name": "p1rdt6530", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6f46c81f-1ceb-4611-9652-4535d88f4fc6"}}}}, {"uuid": "33e0291b-9d5f-4928-95dc-45d472013d5d", "name": "", "x": 38.57798706705615, "y": -122.51470262020904, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b56340a0-81f0-4028-9283-532f0d92a412", "name": "p1rdt6517", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "33e0291b-9d5f-4928-95dc-45d472013d5d"}}}}, {"uuid": "f4d81409-19b9-4e42-a06c-3ce62f8ab4f9", "name": "", "x": 38.579746916502536, "y": -122.51263999956761, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "608945f2-9b19-43bc-83d9-0fe8787b06b4", "name": "p1rdt6517-p1rdt6523x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f4d81409-19b9-4e42-a06c-3ce62f8ab4f9"}}}}, {"uuid": "07f3008d-00cd-4df8-8bea-83653784bac1", "name": "", "x": 38.58000496177514, "y": -122.51234696117584, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "24028ccd-3fd3-4461-b83c-54266f91a385", "name": "p1rdt6520", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "07f3008d-00cd-4df8-8bea-83653784bac1"}}}}, {"uuid": "e3fa98f5-3d51-4345-84df-74893d453208", "name": "", "x": 38.57971971243869, "y": -122.51259440779317, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b540c710-395d-4a35-8dc3-59d37609df09", "name": "p1rdt6523", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e3fa98f5-3d51-4345-84df-74893d453208"}}}}, {"uuid": "515c2487-0a37-42d4-9ec4-2f5d75840d25", "name": "", "x": 38.58012887408336, "y": -122.51206038960157, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "99fa55d1-867c-4db0-8697-b532da10d6d4", "name": "p1rdt6501", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "515c2487-0a37-42d4-9ec4-2f5d75840d25"}}}}, {"uuid": "582e1fdd-0784-4e10-9065-38231440dc00", "name": "", "x": 38.580187053973766, "y": -122.51175395124783, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "89434ebc-1e79-4414-9925-1a14f8e72fd6", "name": "p1rdt6499", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "582e1fdd-0784-4e10-9065-38231440dc00"}}}}, {"uuid": "e50403c5-4866-4194-bb01-be0e09fa1377", "name": "", "x": 38.580244659409736, "y": -122.51143788792888, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e67c889f-e940-4242-9c83-4b5ab673d8a8", "name": "p1rdt6509", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e50403c5-4866-4194-bb01-be0e09fa1377"}}}}, {"uuid": "e659b9f0-3f1e-4b24-ab87-a5123dd51b1c", "name": "", "x": 38.58030980831637, "y": -122.51115038887805, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e165d0d-3f13-4d87-9c4b-fdfa8829f1f3", "name": "p1rdt6508", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e659b9f0-3f1e-4b24-ab87-a5123dd51b1c"}}}}, {"uuid": "b615cc6e-c30f-4996-882a-a05a0058354e", "name": "", "x": 38.580354920781474, "y": -122.5109491558155, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "302d2adf-2199-47b2-9f3c-e428bb409b6f", "name": "p1rdt6521", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b615cc6e-c30f-4996-882a-a05a0058354e"}}}}, {"uuid": "46ab54f2-6e29-4b41-b41f-06337d4964f7", "name": "", "x": 38.58042615056892, "y": -122.51074201742463, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6f7572ed-6443-4e6e-8fb8-0b060b9f17ce", "name": "p1rdt6512", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "46ab54f2-6e29-4b41-b41f-06337d4964f7"}}}}, {"uuid": "3b809375-b5a2-4775-a0b9-2676d6fda7d7", "name": "", "x": 38.58053498950995, "y": -122.5103355002012, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1ef8c502-c06f-43e5-90e6-23bd0ebcf155", "name": "p1rdt6524", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3b809375-b5a2-4775-a0b9-2676d6fda7d7"}}}}, {"uuid": "d69f12ba-021d-452d-bb69-d958c3a8cb16", "name": "", "x": 38.56382999437341, "y": -122.50863846453362, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6372a592-5e2d-41c8-819b-f56bfbb58e19", "name": "p1rdt7091", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d69f12ba-021d-452d-bb69-d958c3a8cb16"}}}}, {"uuid": "69d63238-38a7-42a0-8a20-6c9477697ccb", "name": "", "x": 38.5636996056699, "y": -122.50885698702933, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2324afa4-5274-4392-9a0e-be8dc2bebeba", "name": "p1rdt7091-p1rdt7625x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "69d63238-38a7-42a0-8a20-6c9477697ccb"}}}}, {"uuid": "37c17271-1d66-4530-babf-ba7c9bb6114e", "name": "", "x": 38.56314359789373, "y": -122.50948068684706, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3e6cbe9-d1d3-4c59-981f-dad980f0999b", "name": "p1rdt7625", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "37c17271-1d66-4530-babf-ba7c9bb6114e"}}}}, {"uuid": "dbff52e8-5b75-4845-8a22-7f8073c4f4bc", "name": "", "x": 38.56813752425825, "y": -122.50551166975698, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0cf1844f-a32e-40f2-bc96-05fad3bdd88d", "name": "p1rdt7314", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dbff52e8-5b75-4845-8a22-7f8073c4f4bc"}}}}, {"uuid": "bda52bf5-41bc-46b2-9c3d-66ebc4d33d9b", "name": "", "x": 38.56852875024663, "y": -122.50519721502558, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e86bc267-1607-4aa3-916f-ed826b0adfdc", "name": "p1rdt7318", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bda52bf5-41bc-46b2-9c3d-66ebc4d33d9b"}}}}, {"uuid": "f6353f32-6099-411d-a61a-5f3301e972e7", "name": "", "x": 38.57391341112913, "y": -122.50681689306278, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "231b5cf9-ec2c-47d1-aada-5454926561dd", "name": "p1rdt7307", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f6353f32-6099-411d-a61a-5f3301e972e7"}}}}, {"uuid": "17d081fe-5198-48d6-90b7-5bfaead55094", "name": "", "x": 38.57883713707986, "y": -122.51041811805065, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8431ef4c-78dd-4a39-b15a-95818cfe1d86", "name": "p1rdt6531-p1rdt7307x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "17d081fe-5198-48d6-90b7-5bfaead55094"}}}}, {"uuid": "1a2eb0e7-c58b-47f3-9b0b-89750d713fe9", "name": "", "x": 38.57902238646377, "y": -122.51037187678122, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "483b2d65-b496-4c6f-b01d-66aa3d9d4334", "name": "p1rdt6527", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1a2eb0e7-c58b-47f3-9b0b-89750d713fe9"}}}}, {"uuid": "353fee29-202d-4129-a38e-30d19f45d48a", "name": "", "x": 38.57879504932116, "y": -122.51042237415348, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "385eabe4-8c8e-4354-96ec-931e6c25574d", "name": "p1rdt6531", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "353fee29-202d-4129-a38e-30d19f45d48a"}}}}, {"uuid": "9feadd92-cb06-4c71-af76-75d239af08d9", "name": "", "x": 38.57912969611421, "y": -122.51047132869749, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5bd908fd-8bb8-42c1-8d1b-27c4e2574450", "name": "p1rdt6516", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9feadd92-cb06-4c71-af76-75d239af08d9"}}}}, {"uuid": "f6082925-7139-4fd8-aabe-610e992c29c1", "name": "", "x": 38.57925217424879, "y": -122.51051911433764, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6191a237-532b-44e2-86a8-d9ed56b914b5", "name": "p1rdt6516-p1rdt6524x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f6082925-7139-4fd8-aabe-610e992c29c1"}}}}, {"uuid": "fea2501d-3188-46ea-999f-cd8c413e6241", "name": "", "x": 38.580795923241645, "y": -122.50969387468216, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6a3d9ed9-e2e4-4332-89a2-358441869830", "name": "p1rdt6500-p1rdt6524x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fea2501d-3188-46ea-999f-cd8c413e6241"}}}}, {"uuid": "033688ee-3963-47a5-b30e-240a541604b3", "name": "", "x": 38.58050902502442, "y": -122.51029289847199, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "97b7ef3c-ef16-4c4d-8559-722c5c67749a", "name": "p1rdt6500-p1rdt6524xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "033688ee-3963-47a5-b30e-240a541604b3"}}}}, {"uuid": "5dac2af1-c479-42f6-95d6-e100063c675f", "name": "", "x": 38.58110574867303, "y": -122.50932633681218, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "18b822d0-cbe4-48d7-a818-87e25412d241", "name": "p1rdt6500-p1rdt6515xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5dac2af1-c479-42f6-95d6-e100063c675f"}}}}, {"uuid": "e564fdf3-ba34-4758-b781-3ed6d147914d", "name": "", "x": 38.58088888848231, "y": -122.50970513801667, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0043b26d-8a33-4e32-a963-c4638f943775", "name": "p1rdt6500-p1rdt6515x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e564fdf3-ba34-4758-b781-3ed6d147914d"}}}}, {"uuid": "e0de6dd3-0811-4bf9-a6ab-34bca44c5080", "name": "", "x": 38.58110455057315, "y": -122.5093365351204, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "04c3a970-215a-4e16-a798-80496ffad438", "name": "p1rdt6515-p1rdt6528xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e0de6dd3-0811-4bf9-a6ab-34bca44c5080"}}}}, {"uuid": "cf445906-c1c3-4e18-86a9-61dd94fab3a3", "name": "", "x": 38.58101245616958, "y": -122.50933552593602, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8dcd059f-292b-4f7a-96c1-a3dc185f1eec", "name": "p1rdt6515-p1rdt6528x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cf445906-c1c3-4e18-86a9-61dd94fab3a3"}}}}, {"uuid": "003fd690-4612-4698-bd6f-501feea117d2", "name": "", "x": 38.58147116472299, "y": -122.50902570371277, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "918984ec-3b5f-4174-9bca-771bb10e0f60", "name": "p1rdt6528-p1rdt8898xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "003fd690-4612-4698-bd6f-501feea117d2"}}}}, {"uuid": "0753826c-0c48-45ad-856a-f3ea5b33be40", "name": "", "x": 38.5810944181135, "y": -122.50923796161061, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0156ae64-03dc-4ec0-89c8-8b09a6fc9090", "name": "p1rdt6528-p1rdt8898x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0753826c-0c48-45ad-856a-f3ea5b33be40"}}}}, {"uuid": "fb1daff8-5e70-4d5f-80eb-6a7f365b58e0", "name": "", "x": 38.581587918670415, "y": -122.50894214477799, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b51e96e7-2d7f-42af-9115-c9b1cfb3131c", "name": "p1rdt6532-p1rdt8898x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fb1daff8-5e70-4d5f-80eb-6a7f365b58e0"}}}}, {"uuid": "26aa73db-5454-4f33-ba1b-b5e77e453ecf", "name": "", "x": 38.5813985191289, "y": -122.5089902200945, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "af1707bf-0b2e-4f76-96e7-c01338300d45", "name": "p1rdt6532-p1rdt8898xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "26aa73db-5454-4f33-ba1b-b5e77e453ecf"}}}}, {"uuid": "3573d3c0-5f83-4628-8077-f75cd6245d5b", "name": "", "x": 38.581811295389215, "y": -122.50861649779817, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e4a0469e-1a4a-466d-b18d-f3017b6415ae", "name": "p1rdt6532-p1rdt8902xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3573d3c0-5f83-4628-8077-f75cd6245d5b"}}}}, {"uuid": "311042de-27e1-40a3-87b6-e39cf7548d48", "name": "", "x": 38.581516114078376, "y": -122.50890397337818, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4f373554-9d8a-4a9c-b418-25e67fbb43a9", "name": "p1rdt6532-p1rdt8902x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "311042de-27e1-40a3-87b6-e39cf7548d48"}}}}, {"uuid": "c8f27702-2cc7-4484-93fd-58e51c0fb16e", "name": "", "x": 38.58365359761406, "y": -122.50734451106864, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "68b101ef-d71a-44d2-b1c2-4fc5e9f62499", "name": "p1rdt6052-p1rdt8902x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c8f27702-2cc7-4484-93fd-58e51c0fb16e"}}}}, {"uuid": "a9c3cd5e-cc7b-414b-b943-114ee1ba9f67", "name": "", "x": 38.58185095473939, "y": -122.50866687243757, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "468b1ce8-18fa-423b-99ca-1f3784437721", "name": "p1rdt6052-p1rdt8902xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a9c3cd5e-cc7b-414b-b943-114ee1ba9f67"}}}}, {"uuid": "b27f0dc4-65b4-473e-abdb-c08955bb9f83", "name": "", "x": 38.58373478464309, "y": -122.50725547084005, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "99e2ec8b-60fc-4a79-9eed-0d617babcb1d", "name": "p1rdt6046-p1rdt6052x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b27f0dc4-65b4-473e-abdb-c08955bb9f83"}}}}, {"uuid": "bc30bfc5-b613-42c4-8648-b0da774761d0", "name": "", "x": 38.583726243675486, "y": -122.5073799941088, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "49c69b43-f43b-4576-bbfa-d06b1d27de95", "name": "p1rdt6046-p1rdt6052xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bc30bfc5-b613-42c4-8648-b0da774761d0"}}}}, {"uuid": "fd4305f4-813c-4155-9c8f-cc87a063a114", "name": "", "x": 38.583771567152084, "y": -122.5072620145205, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be3d7f84-84e7-46fc-a9ce-b3e0cf74d1d3", "name": "p1rdt6043-p1rdt6046x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fd4305f4-813c-4155-9c8f-cc87a063a114"}}}}, {"uuid": "65e729c9-72ca-4616-b134-969f2edf5e19", "name": "", "x": 38.583673113710276, "y": -122.507315876951, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a147dd91-5597-40ff-93f9-0522ad3c726c", "name": "p1rdt6043-p1rdt6046xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65e729c9-72ca-4616-b134-969f2edf5e19"}}}}, {"uuid": "78471c56-df6e-47cb-97a4-ec628ff465c4", "name": "", "x": 38.583737845666946, "y": -122.50660841152015, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6f01bba4-b8e8-45ed-af3b-1ac5a287ad46", "name": "p1rdt6043-p1rdt6045xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "78471c56-df6e-47cb-97a4-ec628ff465c4"}}}}, {"uuid": "5dd9ba6c-e61b-463f-a515-95b3ddfd6abd", "name": "", "x": 38.58376143292759, "y": -122.50716343767925, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48d6768a-45e6-48a5-b22d-d5d418cb6221", "name": "p1rdt6043-p1rdt6045x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5dd9ba6c-e61b-463f-a515-95b3ddfd6abd"}}}}, {"uuid": "fcc2a891-40fa-4b5c-bdd9-244cef4e93a7", "name": "", "x": 38.584313677622774, "y": -122.50614079151774, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "34a9d21e-bcf7-4266-9834-60a72878ddd4", "name": "p1rdt6047", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fcc2a891-40fa-4b5c-bdd9-244cef4e93a7"}}}}, {"uuid": "e939a1b6-cedc-4d65-858d-686681519111", "name": "", "x": 38.58376381148312, "y": -122.50665101380328, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0396342e-2dc8-4a01-9da9-513953f9b5fa", "name": "p1rdt6045", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e939a1b6-cedc-4d65-858d-686681519111"}}}}, {"uuid": "b1e530e0-7893-4451-964c-130b7125f7f1", "name": "", "x": 38.58637708588061, "y": -122.50393363509188, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f8898950-d712-40dc-99b5-33882b96b225", "name": "p1rdt6038", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b1e530e0-7893-4451-964c-130b7125f7f1"}}}}, {"uuid": "da6f6b5b-8559-41f7-af03-efce97dc18cd", "name": "", "x": 38.59928901894631, "y": -122.48316671744382, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a086b782-3a8d-44e9-9948-cb7f051219e3", "name": "p1rdt7599", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "da6f6b5b-8559-41f7-af03-efce97dc18cd"}}}}, {"uuid": "609ac35d-fcd1-4ca4-ac26-5508b44e4ee4", "name": "", "x": 38.58770893471679, "y": -122.5028146867888, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3cfe89e9-a7a8-456d-966b-67429017f456", "name": "p1rdt6038-p1rdt7599x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "609ac35d-fcd1-4ca4-ac26-5508b44e4ee4"}}}}, {"uuid": "9b4fde9b-7944-467b-a9f5-52d268a644ee", "name": "", "x": 38.600060944468346, "y": -122.4812911472599, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0809ec5e-d36f-4bea-91b3-962ad6c29606", "name": "p1rdt6221", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9b4fde9b-7944-467b-a9f5-52d268a644ee"}}}}, {"uuid": "24852869-a1c5-4db0-95e5-c320b2bdc195", "name": "", "x": 38.60505176311642, "y": -122.47599334604853, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cdfc617f-fbfb-4e9a-862e-cd5a296748cb", "name": "p1rdt6208", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "24852869-a1c5-4db0-95e5-c320b2bdc195"}}}}, {"uuid": "d3816b74-5540-46d7-bb85-811d4c985b35", "name": "", "x": 38.60037508320662, "y": -122.48099954218519, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e1a5a109-eee6-46be-be53-3fbe4a406575", "name": "p1rdt6208-p1rdt6221x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d3816b74-5540-46d7-bb85-811d4c985b35"}}}}, {"uuid": "09ec30ea-572f-4201-ab0e-bcaa5f62e366", "name": "", "x": 38.60815051684694, "y": -122.4765469245405, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "89f0c671-9d27-4dec-bd37-dc6c56f07e5d", "name": "p1rdt6208-p1rdt8805x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "09ec30ea-572f-4201-ab0e-bcaa5f62e366"}}}}, {"uuid": "af24f76a-b2a7-4be6-998a-9c8b47186469", "name": "", "x": 38.57279151417879, "y": -122.49288162437385, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "17e89212-bc51-4fc2-83d1-4c74a285be23", "name": "p1rdt5662", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "af24f76a-b2a7-4be6-998a-9c8b47186469"}}}}, {"uuid": "9223305e-a3da-4bbd-ada6-4a46ca8d1722", "name": "", "x": 38.57272640832975, "y": -122.49539881317247, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6f2bb66-d966-4228-8a13-96c57e8fbfba", "name": "p1rdt5656-p1rdt5662x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9223305e-a3da-4bbd-ada6-4a46ca8d1722"}}}}, {"uuid": "82ef4fd2-7195-44ec-84b9-64fa3ab7a3f0", "name": "", "x": 38.57265915120934, "y": -122.49564074606137, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f417a58d-5a47-4310-bac6-e8bb95fffc19", "name": "p1rdt5656", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "82ef4fd2-7195-44ec-84b9-64fa3ab7a3f0"}}}}, {"uuid": "4a9b2caa-f848-47c9-a059-957fa52f8f06", "name": "", "x": 38.58485209359688, "y": -122.4751287858777, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "23f0bb81-3c30-45a5-89ca-2011e3881ddb", "name": "p1rdt5183", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4a9b2caa-f848-47c9-a059-957fa52f8f06"}}}}, {"uuid": "b270cdf3-cf3c-4029-a234-1c61167c5fda", "name": "", "x": 38.57451035345935, "y": -122.49113876914703, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a05b2959-a8dd-417b-b566-8f84384a3559", "name": "p1rdt5183-p1rdt5662x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b270cdf3-cf3c-4029-a234-1c61167c5fda"}}}}, {"uuid": "2a0c5a2b-f586-42b2-8ffd-fe3202072fa0", "name": "", "x": 38.58726329125732, "y": -122.47503377407112, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35487e15-57cb-4e19-bef7-49074e5eb9ee", "name": "p1rdt4980-p1rdt5183x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2a0c5a2b-f586-42b2-8ffd-fe3202072fa0"}}}}, {"uuid": "d21b0e02-57ba-4706-b64c-bf0090e0ea77", "name": "", "x": 38.588776084576374, "y": -122.47343214290899, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6c09f718-9379-4281-86f6-55c46e46aec6", "name": "p1rdt5017", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d21b0e02-57ba-4706-b64c-bf0090e0ea77"}}}}, {"uuid": "156e698e-e740-43b4-a724-4c7512ab895f", "name": "", "x": 38.58727709580159, "y": -122.47498276916237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6ddb0629-4947-47ca-83f9-9b7c073db235", "name": "p1rdt4980", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "156e698e-e740-43b4-a724-4c7512ab895f"}}}}, {"uuid": "ddb76e34-841b-49c0-b867-d88bea22d92a", "name": "", "x": 38.58932620721099, "y": -122.47402937641733, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f7f13598-e628-457c-9ba6-d9a0123e882c", "name": "p1rdt4964", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ddb76e34-841b-49c0-b867-d88bea22d92a"}}}}, {"uuid": "22773cea-500b-4798-8aa4-1df98c90efb3", "name": "", "x": 38.58925865771824, "y": -122.47388020936008, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf1c765f-ca54-48cf-806f-6a1b5719c4b0", "name": "p1rdt4964-p1rdt5017x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "22773cea-500b-4798-8aa4-1df98c90efb3"}}}}, {"uuid": "ab497915-2f5e-4f84-afff-5092914cbc85", "name": "", "x": 38.599541593142376, "y": -122.47111831101633, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "42ab6054-1866-49c5-b2ab-3cf27199c1c8", "name": "p1rdt8154", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ab497915-2f5e-4f84-afff-5092914cbc85"}}}}, {"uuid": "6f44f73f-9fc9-4ff0-b2a7-29b6a0732165", "name": "", "x": 38.59202547989681, "y": -122.47391743009182, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fb1e0d86-907d-4564-a90e-c1400917d3ca", "name": "p1rdt4964-p1rdt8154x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6f44f73f-9fc9-4ff0-b2a7-29b6a0732165"}}}}, {"uuid": "ae7ca9ea-21fa-4d1d-81bd-d01623b8672e", "name": "", "x": 38.599346582191174, "y": -122.4698450346779, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b44d5021-4fdb-4618-bcb2-237ecf2e10e4", "name": "p1rdt8153", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ae7ca9ea-21fa-4d1d-81bd-d01623b8672e"}}}}, {"uuid": "da4c3120-9386-4ac0-a965-1d368dc4eb77", "name": "", "x": 38.59932444954078, "y": -122.4697759036714, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "40962258-28d3-4406-9e9e-121f373cce25", "name": "p1rdt8151-p1rdt8153x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "da4c3120-9386-4ac0-a965-1d368dc4eb77"}}}}, {"uuid": "a605e89a-2a49-4fb3-a6a6-235d6b52275e", "name": "", "x": 38.599762625990174, "y": -122.46808190408947, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6c794942-d5ce-481f-9c6a-563a2180a4ba", "name": "p1rdt8151", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a605e89a-2a49-4fb3-a6a6-235d6b52275e"}}}}, {"uuid": "cb85fe25-d34d-4660-90eb-26a04f0f26af", "name": "", "x": 38.605132002398605, "y": -122.47349749138557, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0da91bf8-b687-47df-a7dc-41e6166fd667", "name": "p1rdt9333", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb85fe25-d34d-4660-90eb-26a04f0f26af"}}}}, {"uuid": "5bf299c2-dd95-465a-bd1c-6550b9c7ecd1", "name": "", "x": 38.60218088899386, "y": -122.47169573381588, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0aef77ef-aaaa-4a6e-90ef-87348baaf1a0", "name": "p1rdt8154-p1rdt9333x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5bf299c2-dd95-465a-bd1c-6550b9c7ecd1"}}}}, {"uuid": "7ed57c9a-f3a4-432d-931f-5fcbd8226827", "name": "", "x": 38.608136170076634, "y": -122.47649614861295, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3444af6b-f9d4-4229-b6b2-2114300c3f94", "name": "p1rdt8805", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7ed57c9a-f3a4-432d-931f-5fcbd8226827"}}}}, {"uuid": "9361e3c5-5508-49d1-8324-50197f15d00b", "name": "", "x": 38.609815768546184, "y": -122.4765312522036, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "26ccaeff-3a34-4835-8906-1145148549c6", "name": "p1rdt8802", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9361e3c5-5508-49d1-8324-50197f15d00b"}}}}, {"uuid": "f2365584-be6c-4540-994c-e874243d629f", "name": "", "x": 38.609928396533334, "y": -122.47651694646427, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "401576cc-4ad6-42cd-bf1c-4022da720711", "name": "p1rdt8802-p1rdt9413xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f2365584-be6c-4540-994c-e874243d629f"}}}}, {"uuid": "f510224a-87d0-4a9f-8bfe-1825b789e2b8", "name": "", "x": 38.618837809141326, "y": -122.47838533286804, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e527bf48-b574-43bd-9a5d-484654dc76fe", "name": "p1rdt8802-p1rdt9413x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f510224a-87d0-4a9f-8bfe-1825b789e2b8"}}}}, {"uuid": "f194c891-16c9-4a51-b620-232d3a58f3c7", "name": "", "x": 38.62912673381444, "y": -122.48799793138168, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c0dafde2-c08e-4624-9212-e0fea9e47c2c", "name": "p1rdt5126", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f194c891-16c9-4a51-b620-232d3a58f3c7"}}}}, {"uuid": "93aa763a-d394-4fea-a89b-8ff3e9f2f138", "name": "", "x": 38.64192278671691, "y": -122.50364415036834, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4c8f9ea6-06fb-4fd0-8629-ceea4f32189f", "name": "p1rdt5342", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "93aa763a-d394-4fea-a89b-8ff3e9f2f138"}}}}, {"uuid": "e897b484-4f5d-4511-96ed-69f112c49f0c", "name": "", "x": 38.63755626056743, "y": -122.46589422645306, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7e240270-762d-49f0-a4e4-29fcd6273ce5", "name": "p1rdt7624", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e897b484-4f5d-4511-96ed-69f112c49f0c"}}}}, {"uuid": "0d2d5b6d-abe4-4eb9-ab07-26bdb36af719", "name": "", "x": 38.63942506778048, "y": -122.46168548768624, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b077dc9c-1c6f-4403-ae0c-954e7cc0c692", "name": "p1rdt5476", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0d2d5b6d-abe4-4eb9-ab07-26bdb36af719"}}}}, {"uuid": "148a4099-82af-42f4-b914-66cf29ec0d00", "name": "", "x": 38.643194242872035, "y": -122.47115740856567, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "42b9c576-ddba-4be1-bc64-a37d8cbdfa84", "name": "p1rdt8159", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "148a4099-82af-42f4-b914-66cf29ec0d00"}}}}, {"uuid": "91243721-ce14-4cc8-a69c-acbee3ff9fda", "name": "", "x": 38.64188879325188, "y": -122.47007141909909, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d1ab9716-b9f3-44e5-b9f6-cd83d0904dd3", "name": "p1rdt7624-p1rdt8159x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "91243721-ce14-4cc8-a69c-acbee3ff9fda"}}}}, {"uuid": "cff42dc3-ba94-4c55-a541-87283cc47044", "name": "", "x": 38.64458771393313, "y": -122.47217469285334, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25946c74-15c2-412c-baed-8de5f7aecf98", "name": "p1rdt8161", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cff42dc3-ba94-4c55-a541-87283cc47044"}}}}, {"uuid": "ced643af-8d28-41e7-81bc-9298c8c8a7c1", "name": "", "x": 38.64808407134208, "y": -122.45916844730037, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f31b09da-e4cc-409e-9634-1907480039ff", "name": "p1rdt7253", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ced643af-8d28-41e7-81bc-9298c8c8a7c1"}}}}, {"uuid": "9f7fd998-363e-47bc-a5ec-6acba95517ae", "name": "", "x": 38.64789780072754, "y": -122.44172571021984, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "442de065-9e2a-4ff8-9100-1298d3fe0f6f", "name": "p1rdt8470", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9f7fd998-363e-47bc-a5ec-6acba95517ae"}}}}, {"uuid": "33742eaa-2507-43f4-8e91-c5c625e02232", "name": "", "x": 38.648387196658014, "y": -122.46102160071564, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7a006c5f-e960-4ae2-a37f-d23d7b873a22", "name": "p1rdt7248", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "33742eaa-2507-43f4-8e91-c5c625e02232"}}}}, {"uuid": "7104919f-4adc-4a80-8457-659bf8f006bc", "name": "", "x": 38.64846046981178, "y": -122.46458969235934, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a2f1a631-48f7-4291-9adb-588a66620ebf", "name": "p1rdt7220", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7104919f-4adc-4a80-8457-659bf8f006bc"}}}}, {"uuid": "60ab8c09-8396-4f17-b6fd-aa407a787161", "name": "", "x": 38.64777195633766, "y": -122.46661554016796, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "38b72c12-2e2f-4d83-8f5a-9d8503dc29eb", "name": "p1rdt8160", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "60ab8c09-8396-4f17-b6fd-aa407a787161"}}}}, {"uuid": "11246cdc-f535-43ac-bc2f-283ef1067f9a", "name": "", "x": 38.655229305360514, "y": -122.45615922843626, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "907828f5-8e26-41c4-8fbc-a3744608181a", "name": "p1rdt9075", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "11246cdc-f535-43ac-bc2f-283ef1067f9a"}}}}, {"uuid": "e870ef83-64a3-438a-8029-6d8886b57301", "name": "", "x": 38.65752720541336, "y": -122.45501513442589, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c10b6848-6c57-4243-8cb9-ec28d0a4c9dd", "name": "p1rdt9075-p1rdt9084x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e870ef83-64a3-438a-8029-6d8886b57301"}}}}, {"uuid": "815040ca-6a4c-4405-8579-ff7a3f914bfc", "name": "", "x": 38.65853988991046, "y": -122.45382366130036, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4251587d-600f-40a0-9aec-229fb2e3f2df", "name": "p1rdt9084", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "815040ca-6a4c-4405-8579-ff7a3f914bfc"}}}}, {"uuid": "cd1cc0f4-b4ac-4522-bdd8-e3dc70594d6a", "name": "", "x": 38.652201124748096, "y": -122.4614412233577, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0b7f2f09-976a-45da-8186-229aeedeb689", "name": "p1rdt9077", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cd1cc0f4-b4ac-4522-bdd8-e3dc70594d6a"}}}}, {"uuid": "9d8b7eaa-852a-4c6d-b0c9-1b2426b9217a", "name": "", "x": 38.65243762839318, "y": -122.46214490936109, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1b4ec275-bea8-45f2-94cb-5e24e82179d8", "name": "p1rdt9089", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9d8b7eaa-852a-4c6d-b0c9-1b2426b9217a"}}}}, {"uuid": "0616daa6-3191-4406-9a69-d24e5f3a9dd4", "name": "", "x": 38.65135661168091, "y": -122.46337071841116, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "52c72b52-1c6c-46f6-adbe-1054eb233c20", "name": "p1rdt9090", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0616daa6-3191-4406-9a69-d24e5f3a9dd4"}}}}, {"uuid": "e4ace3e4-f86a-4403-840c-5233a8d47f89", "name": "", "x": 38.65237921170061, "y": -122.46231727928001, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e4d2db3-67c5-4fef-996a-5774803c89b1", "name": "p1rdt9089-p1rdt9090x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e4ace3e4-f86a-4403-840c-5233a8d47f89"}}}}, {"uuid": "f6b9afad-4208-4121-9829-dc64e012f791", "name": "", "x": 38.649831613431125, "y": -122.46561633896845, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3fd32c7-2866-4699-93a8-dd3a9997d349", "name": "p1rdt9469", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f6b9afad-4208-4121-9829-dc64e012f791"}}}}, {"uuid": "b4d949aa-8e70-4f2e-b001-812a6d42b686", "name": "", "x": 38.65039847441097, "y": -122.46468794326384, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "708803a5-3daf-4892-96e3-b182e2d214ec", "name": "p1rdt9090-p1rdt9469x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b4d949aa-8e70-4f2e-b001-812a6d42b686"}}}}, {"uuid": "ba7b18f7-6460-41e0-9b2b-3f9af5c9c69c", "name": "", "x": 38.64456173566906, "y": -122.4721320674015, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c8ecbd5b-6db5-44a0-b2a8-0233d4eb5b20", "name": "p1rdt8160-p1rdt8161xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ba7b18f7-6460-41e0-9b2b-3f9af5c9c69c"}}}}, {"uuid": "331f72b2-c8fa-4979-a0f4-6b7c8286c289", "name": "", "x": 38.645703216313166, "y": -122.47060639662344, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cc9cbaf2-05bd-49aa-bd14-a363d4970d0f", "name": "p1rdt8160-p1rdt8161x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "331f72b2-c8fa-4979-a0f4-6b7c8286c289"}}}}, {"uuid": "d7c8d0dd-b7e9-4606-b2ed-56da52b32e46", "name": "", "x": 38.641446776145905, "y": -122.48088775120242, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "22db53ea-6d9a-4527-9b36-34a4bcd2c74f", "name": "p1rdt5236", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d7c8d0dd-b7e9-4606-b2ed-56da52b32e46"}}}}, {"uuid": "f3e02c92-fbc6-412b-8ea3-c179fa8c1404", "name": "", "x": 38.64423596256915, "y": -122.47297284989183, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "67967bdd-155c-49fd-8d4c-29b40415a243", "name": "p1rdt5236-p1rdt8161x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f3e02c92-fbc6-412b-8ea3-c179fa8c1404"}}}}, {"uuid": "4ae6ae6c-48be-4637-a5e1-b25dc9fa53b0", "name": "", "x": 38.64189681984152, "y": -122.50360151499711, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9bbfae79-a578-4ff2-b622-3dddd9859ac8", "name": "p1rdt5236-p1rdt5342x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ae6ae6c-48be-4637-a5e1-b25dc9fa53b0"}}}}, {"uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac", "name": "", "limit_type": "min", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "base"}}, "value": {"value": 0.26327172275046934, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}}, {"uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b", "name": "", "limit_type": "max", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "base"}}, "value": {"value": 0.2909845356715714, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}}, {"uuid": "c506c458-594e-4c5f-9e1f-7e22db8220b6", "name": "", "x": 38.62487405627925, "y": -122.44771212016306, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9750085f-4afd-48ee-89f3-edbe9687b242", "name": "p1rdt5154lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c506c458-594e-4c5f-9e1f-7e22db8220b6"}}}}, {"uuid": "090a2c8f-a953-4cac-b416-8e61fbf2d4b4", "name": "", "x": 38.62484806916583, "y": -122.44766951523545, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "08331744-08b7-455e-b2ca-284cae95fb06", "name": "p1rlv10539", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "090a2c8f-a953-4cac-b416-8e61fbf2d4b4"}}}}, {"uuid": "80a16f1a-9fbf-462f-b254-04a16da0b948", "name": "", "x": 38.62592881156844, "y": -122.44183363220685, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7235cf3a-dd26-47f7-884c-6335024a3064", "name": "p1rdt7632lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "80a16f1a-9fbf-462f-b254-04a16da0b948"}}}}, {"uuid": "18196f08-5ffc-4531-9ce1-984f0bd06c0b", "name": "", "x": 38.62591502181451, "y": -122.4418846707521, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "606bf8f6-d745-4220-8cae-e01ffd22f669", "name": "p1rlv16271", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "18196f08-5ffc-4531-9ce1-984f0bd06c0b"}}}}, {"uuid": "4739b7b5-d6d6-4a0f-bdca-ee44962ae707", "name": "", "x": 38.6268422350558, "y": -122.44358917844923, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b336e76f-17f3-4f5d-ba84-f24c3a4e3eed", "name": "p1rdt9265", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4739b7b5-d6d6-4a0f-bdca-ee44962ae707"}}}}, {"uuid": "9eb2fe35-b2d7-4c73-bc6a-9b8f07206031", "name": "", "x": 38.62595431848947, "y": -122.4417905580223, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "36e7cd28-6795-41d5-847d-92347871384f", "name": "p1rdt7632", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9eb2fe35-b2d7-4c73-bc6a-9b8f07206031"}}}}, {"uuid": "525621bc-eb00-4748-9592-9b3796d898ad", "name": "", "x": 38.626761518561686, "y": -122.44366797538842, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60837f06-40cb-4f12-b36f-fe5e502c96d9", "name": "p1rdt5140-p1rdt9265x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "525621bc-eb00-4748-9592-9b3796d898ad"}}}}, {"uuid": "0510f432-bc9d-4b48-a131-cc95b95f987b", "name": "", "x": 38.61321159266958, "y": -122.45774317693665, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a6614f5e-517f-46cf-b049-09337d57228a", "name": "p1rdt6279lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0510f432-bc9d-4b48-a131-cc95b95f987b"}}}}, {"uuid": "ffeb8cee-60ff-44ce-9b89-c90087251208", "name": "", "x": 38.613584450478484, "y": -122.45866725103048, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d46fd47-37f5-48a0-ba0d-d0746e6e6da3", "name": "p1rlv13061", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ffeb8cee-60ff-44ce-9b89-c90087251208"}}}}, {"uuid": "a7225ef2-cbbe-49a3-8b48-2c2e91ae95c5", "name": "", "x": 38.6133095747888, "y": -122.45770086863982, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cb21415c-fc85-4197-82e5-545cb7be2ce9", "name": "p1rdt6270-p1rdt6279x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a7225ef2-cbbe-49a3-8b48-2c2e91ae95c5"}}}}, {"uuid": "099a9c55-b1e0-4be0-af0f-adc080f914d6", "name": "", "x": 38.612910443068216, "y": -122.45907432656523, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e1565cfb-f699-47db-9cbf-a76c32e3ea69", "name": "p1rdt6270-p1rdt6279xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "099a9c55-b1e0-4be0-af0f-adc080f914d6"}}}}, {"uuid": "0c2c958b-2765-4873-9426-4fa8b298bc4c", "name": "", "x": 38.61301688005345, "y": -122.45941707430568, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5c579309-9c05-4bae-ab97-2eca485e5ea7", "name": "p1rdt6270-p1rdt6279xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0c2c958b-2765-4873-9426-4fa8b298bc4c"}}}}, {"uuid": "be1c5948-74ad-4790-a797-5c9bd7d6e7f9", "name": "", "x": 38.61683166262397, "y": -122.45474510217191, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "07992f45-0c92-4a10-837d-4f58599d9b75", "name": "p1rdt6273lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be1c5948-74ad-4790-a797-5c9bd7d6e7f9"}}}}, {"uuid": "6be47282-79b1-4511-94e5-ba580ff9b1bf", "name": "", "x": 38.61682643350382, "y": -122.4546916792451, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "051eba03-4728-4626-8add-5410b5326dc7", "name": "p1rlv13050", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6be47282-79b1-4511-94e5-ba580ff9b1bf"}}}}, {"uuid": "b647496e-436e-4fc4-84b3-eded4e8a1dbb", "name": "", "x": 38.6162564916241, "y": -122.45492283366434, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b2f8b91d-339f-4151-90df-b0cad5c2f05a", "name": "p1rdt6268", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b647496e-436e-4fc4-84b3-eded4e8a1dbb"}}}}, {"uuid": "db758a6a-9d1d-4ea1-816d-048640f12fc9", "name": "", "x": 38.61683285323747, "y": -122.45479901485551, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4d04f281-f394-432b-8b5c-cc1acb741369", "name": "p1rdt6273", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "db758a6a-9d1d-4ea1-816d-048640f12fc9"}}}}, {"uuid": "57780dd4-af7d-49dd-9de4-ad650c6a06a4", "name": "", "x": 38.61589336043255, "y": -122.45601994462623, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b31c2adb-e4f4-4211-aac7-f317bf325d12", "name": "p1rdt6268-p1rdt6276xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "57780dd4-af7d-49dd-9de4-ad650c6a06a4"}}}}, {"uuid": "d29d0187-de06-4d15-97ce-b21f4a1f04fa", "name": "", "x": 38.61634551176407, "y": -122.45552215649514, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ce404489-b775-486b-9379-a30c801f6f94", "name": "p1rdt6268-p1rdt6276xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d29d0187-de06-4d15-97ce-b21f4a1f04fa"}}}}, {"uuid": "8012248e-cccf-438a-8364-34bcc51f62c8", "name": "", "x": 38.61623050711647, "y": -122.4548802311643, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "68d2e030-852f-44f6-9e02-d5587a1fc6a0", "name": "p1rdt6268-p1rdt6276x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8012248e-cccf-438a-8364-34bcc51f62c8"}}}}, {"uuid": "a176b6e8-4da7-46f4-9ac6-cced26eb5e19", "name": "", "x": 38.616457957404585, "y": -122.4575517341824, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "51eefb94-724e-4dfe-9823-0f6cf8f56101", "name": "p1rdt6278", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a176b6e8-4da7-46f4-9ac6-cced26eb5e19"}}}}, {"uuid": "cc466d34-d930-4734-9094-61f34464eca8", "name": "", "x": 38.61591934452827, "y": -122.45606254734442, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "315af04d-a032-43a8-a2da-b9e68fd21f39", "name": "p1rdt6276", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc466d34-d930-4734-9094-61f34464eca8"}}}}, {"uuid": "1f9d8fc5-698a-40b8-adc4-7b10d6df6183", "name": "", "x": 38.616039041002885, "y": -122.45805901946764, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1dd4f893-7921-41c3-9e9e-d33e3680a999", "name": "p1rdt6277", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1f9d8fc5-698a-40b8-adc4-7b10d6df6183"}}}}, {"uuid": "d1d13ad6-e94b-45fe-8357-d6f81f83b860", "name": "", "x": 38.61556885068546, "y": -122.45905436217652, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "699595d6-8e08-41b1-8c3a-2aef170bb5f7", "name": "p1rdt6269-p1rdt6277x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1d13ad6-e94b-45fe-8357-d6f81f83b860"}}}}, {"uuid": "36918a38-3551-4a37-9465-3fda5261e1f9", "name": "", "x": 38.58377814515449, "y": -122.50670177876174, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "70bad714-71c1-4341-ac40-76312417dd03", "name": "p1rdt6045lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "36918a38-3551-4a37-9465-3fda5261e1f9"}}}}, {"uuid": "9e1584f4-9724-4c9e-ac13-d6b255344a7e", "name": "", "x": 38.58357344171333, "y": -122.50663601797484, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cc71e486-4a44-466d-bc57-85591b269949", "name": "p1rlv12555", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9e1584f4-9724-4c9e-ac13-d6b255344a7e"}}}}, {"uuid": "451fea3b-acbb-4e8f-9fea-77a4fda7de34", "name": "", "x": 38.58366602224418, "y": -122.50744271243232, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9d830a1b-6971-4f4d-99bd-945e0785b5aa", "name": "p1rdt6052lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "451fea3b-acbb-4e8f-9fea-77a4fda7de34"}}}}, {"uuid": "659f553d-9923-4b22-86f3-a0526d8303ff", "name": "", "x": 38.583654744101715, "y": -122.507354817808, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "29476f95-f85b-4843-a847-3d9d99da3b74", "name": "p1rlv12567", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "659f553d-9923-4b22-86f3-a0526d8303ff"}}}}, {"uuid": "95152bb2-254c-4961-8510-d3ef791e29bc", "name": "", "x": 38.58176166095416, "y": -122.50864860767257, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d1c8eb9-7f79-49ad-9e93-6c7cdcc95e22", "name": "p1rdt8902lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "95152bb2-254c-4961-8510-d3ef791e29bc"}}}}, {"uuid": "81cdea77-c892-4abd-93bc-946ff7be1759", "name": "", "x": 38.58164914879979, "y": -122.50832144611942, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a02024b5-aa74-4e07-b043-a7a0e8b3e816", "name": "p1rlv19164", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "81cdea77-c892-4abd-93bc-946ff7be1759"}}}}, {"uuid": "309b639b-14c0-47a6-8c13-ad4e20b47956", "name": "", "x": 38.57552859055316, "y": -122.51515559102107, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c3f191ff-f8f2-4f13-af83-e67d1fdd366a", "name": "p1rdt6537lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "309b639b-14c0-47a6-8c13-ad4e20b47956"}}}}, {"uuid": "5cf221cf-25ef-476c-af52-9402540f80d9", "name": "", "x": 38.575486581492186, "y": -122.51516107668057, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fe1a5da7-bdac-46a6-ab32-addc4f02a296", "name": "p1rlv13720", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5cf221cf-25ef-476c-af52-9402540f80d9"}}}}, {"uuid": "b8957f06-0823-465f-8389-1f4b1f7e4316", "name": "", "x": 38.575576829321776, "y": -122.51521644999882, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "45aca6e5-a8ee-4f45-80f3-e227379d33af", "name": "p1rdt6530-p1rdt6537x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b8957f06-0823-465f-8389-1f4b1f7e4316"}}}}, {"uuid": "af35ac47-262a-4419-82ab-afddde769dc1", "name": "", "x": 38.57557088455815, "y": -122.51515412712796, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "902291fa-9561-4f40-a4b7-4fd9fdded417", "name": "p1rdt6537", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "af35ac47-262a-4419-82ab-afddde769dc1"}}}}, {"uuid": "7cdaa1b9-0c0d-4944-9718-3cdadc5f131b", "name": "", "x": 38.56672395074998, "y": -122.5002666540795, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "41e61263-feb6-4264-965a-fd1309d997a1", "name": "p1rdt7313lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7cdaa1b9-0c0d-4944-9718-3cdadc5f131b"}}}}, {"uuid": "a5a69c8d-398f-44f6-a78a-cb55e8a7fb4d", "name": "", "x": 38.566682740186856, "y": -122.50025430587122, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "13eabcb1-332a-4c7a-8042-214ada721424", "name": "p1rlv15628", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a5a69c8d-398f-44f6-a78a-cb55e8a7fb4d"}}}}, {"uuid": "6dab9a69-1039-4816-bab2-3d238cf7bc4b", "name": "", "x": 38.566766241557346, "y": -122.50026502368816, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1a3a5e1c-77a2-4a9d-89e0-7d1c94176787", "name": "p1rdt7313", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6dab9a69-1039-4816-bab2-3d238cf7bc4b"}}}}, {"uuid": "44f035bc-740e-4f8c-86ee-3b2ed3b46052", "name": "", "x": 38.563855959465826, "y": -122.50868105587648, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f0c42b48-7ca4-465f-b17c-048cb5f6d79b", "name": "p1rdt7091lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "44f035bc-740e-4f8c-86ee-3b2ed3b46052"}}}}, {"uuid": "912aee73-148f-4e1f-af3c-8095f22549b6", "name": "", "x": 38.56387029221525, "y": -122.50873180728178, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "64634ab5-a5b0-45ae-9763-7d0be029350f", "name": "p1rlv15196", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "912aee73-148f-4e1f-af3c-8095f22549b6"}}}}, {"uuid": "3e40222f-8bb5-4b72-b0a8-3c1677f45386", "name": "", "x": 38.56720551439007, "y": -122.4954680905678, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f718935b-704d-4374-9172-856511e1eddd", "name": "p1rdt5658lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e40222f-8bb5-4b72-b0a8-3c1677f45386"}}}}, {"uuid": "e55dae49-706c-4edc-b323-1c5994e7842a", "name": "", "x": 38.56720030404839, "y": -122.4954147012043, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4747e0f3-2a66-4e5a-8160-ac0aabe34489", "name": "p1rlv11679", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e55dae49-706c-4edc-b323-1c5994e7842a"}}}}, {"uuid": "a496582f-3ab4-48b4-8bbe-9d948841118a", "name": "", "x": 38.56720668600247, "y": -122.49552196704039, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "81d6db26-881f-4cae-9514-df4c1e71c76e", "name": "p1rdt5658", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a496582f-3ab4-48b4-8bbe-9d948841118a"}}}}, {"uuid": "1e229978-bde6-49d6-88ef-a59ac7598fc7", "name": "", "x": 38.65216422809464, "y": -122.48679328426424, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0bab7e6b-74a6-4fe4-95e1-4ef96084f730", "name": "p1rdt5236-p1rdt8138x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1e229978-bde6-49d6-88ef-a59ac7598fc7"}}}}, {"uuid": "8e8eb4b7-82cc-4705-8d79-553180a38da3", "name": "", "x": 38.61289959602905, "y": -122.4594654458467, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "658514b3-59fd-44b7-95d6-a34cafcb47c5", "name": "p1rdt6270-p1rdt6271x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8e8eb4b7-82cc-4705-8d79-553180a38da3"}}}}, {"uuid": "cef73316-4e05-44ba-b446-d7d3a9c4fde4", "name": "", "x": 38.58084780242867, "y": -122.5096251869554, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c9938a5c-b1cd-4592-814d-324ff2eb6644", "name": "p1rdt6500-p1rdt6519x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cef73316-4e05-44ba-b446-d7d3a9c4fde4"}}}}, {"uuid": "10ccc3bc-3003-4ac7-b98e-a169941c9b43", "name": "", "x": 38.58086518694643, "y": -122.50946246615781, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "addd9f38-279f-4d9e-b216-38faef1940c7", "name": "p1rdt6519", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10ccc3bc-3003-4ac7-b98e-a169941c9b43"}}}}, {"uuid": "95e0e7cd-6529-4d7c-a009-4b5b33ed93ec", "name": "", "x": 38.58105786983961, "y": -122.50938072179505, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "acd6da90-895c-4d2c-80b4-1712b3949993", "name": "p1rdt6515-p1rdt6535x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "95e0e7cd-6529-4d7c-a009-4b5b33ed93ec"}}}}, {"uuid": "18ac8c15-27a3-4d77-af88-1d8055d5385e", "name": "", "x": 38.581060631396625, "y": -122.50954681794376, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b13053e-033e-4fe9-8eb3-89389e4bdc2b", "name": "p1rdt6535", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "18ac8c15-27a3-4d77-af88-1d8055d5385e"}}}}, {"uuid": "a4a67019-41da-4511-8cc7-c84f86f0e2b8", "name": "", "x": 38.58103206808594, "y": -122.50926637153142, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e0103161-4b16-4d25-a1f3-5a939317461f", "name": "p1rdt6515-p1rdt6536x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a4a67019-41da-4511-8cc7-c84f86f0e2b8"}}}}, {"uuid": "ba0629ba-5833-457a-b255-6ff9469bcdcf", "name": "", "x": 38.58096111560494, "y": -122.50912674534362, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8f5cda74-5e33-4c52-8b2c-76bcd5e6c5cb", "name": "p1rdt6536", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ba0629ba-5833-457a-b255-6ff9469bcdcf"}}}}, {"uuid": "ece0a614-8728-4152-bad4-c2f58d2cff06", "name": "", "x": 38.580843572870805, "y": -122.50968387919501, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "78b3b940-c277-441f-b2b3-83525ed85fcb", "name": "p1rdt6500", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ece0a614-8728-4152-bad4-c2f58d2cff06"}}}}, {"uuid": "a6631bf9-7546-47a7-b00b-9c15f3d90c15", "name": "", "x": 38.58105789188953, "y": -122.50931876846892, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f1537ab1-dc7c-4bbd-b347-fc740d54fcf7", "name": "p1rdt6515", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a6631bf9-7546-47a7-b00b-9c15f3d90c15"}}}}, {"uuid": "af42ea4f-a084-4c6c-9c59-95018e4fa65f", "name": "", "x": 38.58107734523138, "y": -122.50929094375307, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6ef5115d-ad7b-4671-b984-b9fd5969bf61", "name": "p1rdt6528", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "af42ea4f-a084-4c6c-9c59-95018e4fa65f"}}}}, {"uuid": "a3ccc5ea-84ec-45d4-9bc1-bd1015516736", "name": "", "x": 38.581426753801445, "y": -122.50903479519879, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9d887dbc-43bd-413e-8e72-5c95a2ed0be8", "name": "p1rdt8898", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a3ccc5ea-84ec-45d4-9bc1-bd1015516736"}}}}, {"uuid": "876c20e0-46d2-4171-bdcd-67bcae4f8a23", "name": "", "x": 38.581560713176216, "y": -122.50889655325749, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d9f12ed7-454c-4cc9-a631-377121a07ba5", "name": "p1rdt6532", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "876c20e0-46d2-4171-bdcd-67bcae4f8a23"}}}}, {"uuid": "549b0bcc-dd32-407b-a3ba-c7ee12c8c856", "name": "", "x": 38.5818039862915, "y": -122.50867642493746, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4f44ec9b-338a-4ae1-a26b-26422f218c13", "name": "p1rdt8902", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "549b0bcc-dd32-407b-a3ba-c7ee12c8c856"}}}}, {"uuid": "8ac7b79d-e22a-43be-ae62-480551b5dfe1", "name": "", "x": 38.58368183290747, "y": -122.50738908690626, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c10f182d-aa76-4633-9a84-f41e20b97da1", "name": "p1rdt6052", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8ac7b79d-e22a-43be-ae62-480551b5dfe1"}}}}, {"uuid": "58116fa8-1381-4b41-93df-1ced21da2f7f", "name": "", "x": 38.58371771254211, "y": -122.50730845553447, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "67bc3ce6-e23d-4899-b0e8-9783225338ff", "name": "p1rdt6046", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "58116fa8-1381-4b41-93df-1ced21da2f7f"}}}}, {"uuid": "bb9375da-bd01-4e61-94d0-a3db80a2f7d9", "name": "", "x": 38.58374436086863, "y": -122.50721642241469, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "87e05b2f-c346-452c-9c72-a6db090c3124", "name": "p1rdt6043", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bb9375da-bd01-4e61-94d0-a3db80a2f7d9"}}}}, {"uuid": "bf36148b-0b67-4e21-ba79-bb14f0d9b9a2", "name": "", "x": 38.613253340793605, "y": -122.45775080611988, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "632d8db5-5220-4188-94f0-f6131253820b", "name": "p1rdt6279", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bf36148b-0b67-4e21-ba79-bb14f0d9b9a2"}}}}, {"uuid": "3aa676ae-ebff-47f5-8913-13e464709b7d", "name": "", "x": 38.58052230427394, "y": -122.51054930766253, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "edf27f1d-b486-434e-92be-963bdeb26090", "name": "p1rdt6501-p1rdt9468x_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3aa676ae-ebff-47f5-8913-13e464709b7d"}}}}, {"uuid": "6eae70b0-8f38-48a1-8e62-c39823216437", "name": "", "x": 38.58140313016848, "y": -122.50982713555175, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e62ba05d-920f-4f55-b1c6-3aa078e0073d", "name": "p1rdt8902-p1rdt9377x_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6eae70b0-8f38-48a1-8e62-c39823216437"}}}}, {"uuid": "9cecf942-f125-4fc9-9f2d-23b443d58d44", "name": "", "x": 38.649913359314574, "y": -122.40176189052858, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8ccc9dcb-3a72-4f11-9bcf-e3a7f1a21985", "name": "p1rdt5195_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9cecf942-f125-4fc9-9f2d-23b443d58d44"}}}}, {"uuid": "54c5be93-4f2a-45c3-9b63-c3f7a44b0522", "name": "", "x": 38.68940056320115, "y": -122.44266975467744, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6b3c997d-cd47-439c-aeb9-326e12c2b869", "name": "p1rdt28lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "54c5be93-4f2a-45c3-9b63-c3f7a44b0522"}}}}, {"uuid": "14523271-bd86-41a7-aced-3e5e00efc0df", "name": "", "x": 38.68955085092013, "y": -122.44265311463495, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8ccef6af-4bf6-44dc-b292-2bf9503a374a", "name": "p1rlv51", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "14523271-bd86-41a7-aced-3e5e00efc0df"}}}}, {"uuid": "d1625529-9e08-4fbd-818b-487e4402e667", "name": "", "x": 38.689199515506125, "y": -122.44267883689947, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b3c62646-6132-41ef-ba14-a06789885cd5", "name": "p1rlv53", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1625529-9e08-4fbd-818b-487e4402e667"}}}}, {"uuid": "ab3986aa-349f-43ce-8609-e96791097421", "name": "", "x": 38.68719967792895, "y": -122.44202477655993, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "61fc3980-6aa4-415c-91c1-10d32c7c359c", "name": "p1rdt29lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ab3986aa-349f-43ce-8609-e96791097421"}}}}, {"uuid": "1232b5c1-d445-40db-859a-e61961a053ad", "name": "", "x": 38.68717368875977, "y": -122.44198213704887, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fec0a162-4b0c-4577-b878-8dbc7c9935fc", "name": "p1rlv52", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1232b5c1-d445-40db-859a-e61961a053ad"}}}}, {"uuid": "c345d1a1-14da-4a8c-a8bb-3e2c621c0204", "name": "", "x": 38.70237353390803, "y": -122.38204661340717, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4d2be3b5-dbfc-4099-af9a-96368e60fe23", "name": "p1rdt30lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c345d1a1-14da-4a8c-a8bb-3e2c621c0204"}}}}, {"uuid": "bc6d9158-f2b3-4cb0-9930-c6984365a7fc", "name": "", "x": 38.702248770449096, "y": -122.38177565760685, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "346dad85-3bf8-41a6-97ea-6b3b40a7f22e", "name": "p1rlv62", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bc6d9158-f2b3-4cb0-9930-c6984365a7fc"}}}}, {"uuid": "a7109162-f295-4719-8eaf-7cdf8aee7649", "name": "", "x": 38.70225996977785, "y": -122.382189570322, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c89ec162-cda3-4c40-8833-3fff085538ba", "name": "p1rdm56", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a7109162-f295-4719-8eaf-7cdf8aee7649"}}}}, {"uuid": "e4ce90f8-02a1-46dd-96c2-c7b8972e5363", "name": "", "x": 38.70215104431212, "y": -122.38204100448107, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "20010301-32ce-4cc0-ab59-04ef3bcd35d7", "name": "p1rlv54", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e4ce90f8-02a1-46dd-96c2-c7b8972e5363"}}}}, {"uuid": "e1200df2-4a75-4e15-8956-eaeb9ff30ccf", "name": "", "x": 38.70125472363682, "y": -122.37955319837823, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "59ff3c1b-38f4-4a33-86fa-e956951c0f2c", "name": "p1rdm58", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e1200df2-4a75-4e15-8956-eaeb9ff30ccf"}}}}, {"uuid": "a1fd30d9-7410-4c78-ba22-7372d3d81998", "name": "", "x": 38.701204180575694, "y": -122.37968411246109, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "36bdbc4e-edfa-425a-8e4c-e6123b567555", "name": "p1rlv55", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a1fd30d9-7410-4c78-ba22-7372d3d81998"}}}}, {"uuid": "4662f7a8-368e-4162-b872-3bc8f29531a6", "name": "", "x": 38.70120618742273, "y": -122.37889811298928, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f678ceb4-b717-44a5-9db9-f698bece6935", "name": "p1rdm60", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4662f7a8-368e-4162-b872-3bc8f29531a6"}}}}, {"uuid": "1b5b11ca-9f19-43b7-b13f-e7164ddc0619", "name": "", "x": 38.701314750425446, "y": -122.37897767463447, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25b891ce-797a-4a4d-b664-4225fba806c4", "name": "p1rlv152", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1b5b11ca-9f19-43b7-b13f-e7164ddc0619"}}}}, {"uuid": "833f8c3b-2661-4791-8f47-042ec9e5cd7a", "name": "", "x": 38.70133109954647, "y": -122.37964493055146, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3510eedd-535c-4e58-b81e-c5ec09030479", "name": "p1rdt31lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "833f8c3b-2661-4791-8f47-042ec9e5cd7a"}}}}, {"uuid": "3acc2e31-a59c-40ed-95ee-1341730b1e49", "name": "", "x": 38.7016002020804, "y": -122.3801252205059, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3a0a4841-bf31-4498-98d9-115cc159981c", "name": "p1rdm59", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3acc2e31-a59c-40ed-95ee-1341730b1e49"}}}}, {"uuid": "d52a647b-da63-4a12-93c7-3e1012a0e903", "name": "", "x": 38.701475019236376, "y": -122.38031030323685, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a32ee184-f677-4333-b7ee-7bc30ab41467", "name": "p1rlv58", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d52a647b-da63-4a12-93c7-3e1012a0e903"}}}}, {"uuid": "a84c9fe6-6be3-4d57-b05a-1e617ace728e", "name": "", "x": 38.70278615488254, "y": -122.38061347297433, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e374d6d6-1e75-4808-b65a-c7033e1bd528", "name": "p1rdt32lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a84c9fe6-6be3-4d57-b05a-1e617ace728e"}}}}, {"uuid": "675a026f-8f3a-4d6a-b336-f2a97a0172d3", "name": "", "x": 38.70279286082068, "y": -122.38071294165577, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ec2c1edd-78b1-4436-85cc-2fbc7d880b87", "name": "p1rlv414", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "675a026f-8f3a-4d6a-b336-f2a97a0172d3"}}}}, {"uuid": "3435bd69-9f3b-43ca-98a0-ec2de3c18d97", "name": "", "x": 38.70248568513053, "y": -122.3805660873002, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cef7aa37-7ca0-4130-9bcd-1804a811245a", "name": "p1rdm61", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3435bd69-9f3b-43ca-98a0-ec2de3c18d97"}}}}, {"uuid": "4e71fca8-0890-4db7-be87-fe294459781e", "name": "", "x": 38.702478683531616, "y": -122.38094565722146, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4694811a-ba43-4c78-b957-5209b1d961e2", "name": "p1rlv56", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4e71fca8-0890-4db7-be87-fe294459781e"}}}}, {"uuid": "4854c4d7-5bd8-4724-af9a-4acd5b27e364", "name": "", "x": 38.70162164245257, "y": -122.38472111973375, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "065c8583-45e5-466c-b4c0-1c66bf970abe", "name": "p1rdt33lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4854c4d7-5bd8-4724-af9a-4acd5b27e364"}}}}, {"uuid": "4199baea-30b5-43b2-b88c-0c1faf4aee21", "name": "", "x": 38.701985008267755, "y": -122.38473348273297, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0f7dbd18-1cbe-49d3-b490-3c46cf8e37f1", "name": "p1rlv170", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4199baea-30b5-43b2-b88c-0c1faf4aee21"}}}}, {"uuid": "78bbc070-dc8e-4410-8d4e-4f606565bf7c", "name": "", "x": 38.70159540402429, "y": -122.38433431596432, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b0538c66-18d7-440e-9efd-6b2945d50f2b", "name": "p1rdm63", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "78bbc070-dc8e-4410-8d4e-4f606565bf7c"}}}}, {"uuid": "fa50dadb-5ee3-46b3-a4eb-9ab06e3f7516", "name": "", "x": 38.70131629597425, "y": -122.38438270952352, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "925cb3b7-4ced-4a36-913f-e6851ed79b98", "name": "p1rlv57", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa50dadb-5ee3-46b3-a4eb-9ab06e3f7516"}}}}, {"uuid": "1d46a1cc-204e-4ea8-8397-e723f39f0b45", "name": "", "x": 38.70167064130821, "y": -122.38493167921865, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cfa2eaff-b163-46ce-b6e5-516680d39bc3", "name": "p1rdm64", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d46a1cc-204e-4ea8-8397-e723f39f0b45"}}}}, {"uuid": "7e6bb48b-c23f-44a8-978e-196d3e00c442", "name": "", "x": 38.70145424916845, "y": -122.38491053257476, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d22bf2f5-74cc-47c7-ae3b-410fba27c113", "name": "p1rlv61", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7e6bb48b-c23f-44a8-978e-196d3e00c442"}}}}, {"uuid": "0bcbb846-2e59-45fb-83c2-51c537155626", "name": "", "x": 38.7023106935151, "y": -122.37870903978225, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "72ee0111-4849-4280-b3c9-c0627d1a6c09", "name": "p1rdm66", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0bcbb846-2e59-45fb-83c2-51c537155626"}}}}, {"uuid": "4825661b-6b25-4827-b894-da341ab1f2d2", "name": "", "x": 38.7024768400754, "y": -122.37889862189955, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b80bdb24-4bbf-4a57-bd5f-6a5ec9d484dd", "name": "p1rlv59", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4825661b-6b25-4827-b894-da341ab1f2d2"}}}}, {"uuid": "363693fc-8724-4e30-9695-ca77f5fdac20", "name": "", "x": 38.70222160936453, "y": -122.37888535297411, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "553a6868-acec-4492-a52d-5aa08414c612", "name": "p1rdt34lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "363693fc-8724-4e30-9695-ca77f5fdac20"}}}}, {"uuid": "236fb449-47ee-42e4-993c-3997b0af760e", "name": "", "x": 38.70217983407473, "y": -122.37897019250839, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "713c1538-ceb4-46df-a996-6c591c0f8e40", "name": "p1rdm67", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "236fb449-47ee-42e4-993c-3997b0af760e"}}}}, {"uuid": "8587aa60-c8a0-494d-8deb-56c4d60053f5", "name": "", "x": 38.70224401225384, "y": -122.37917664191762, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "64a67ed2-a563-4378-b6ac-d9a95339e862", "name": "p1rlv67", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8587aa60-c8a0-494d-8deb-56c4d60053f5"}}}}, {"uuid": "a4d2bd60-6cec-4e24-9421-7fcc9429131d", "name": "", "x": 38.701765866802305, "y": -122.38301785787249, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f98cc066-fca3-4489-9770-047caee3e742", "name": "p1rdt35lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a4d2bd60-6cec-4e24-9421-7fcc9429131d"}}}}, {"uuid": "afa28b82-3110-4dbb-add6-0fa5d3d6fb16", "name": "", "x": 38.701398104123946, "y": -122.38280649214893, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7eb0d1e8-f85e-493e-b69b-26437fdb8ad9", "name": "p1rlv60", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "afa28b82-3110-4dbb-add6-0fa5d3d6fb16"}}}}, {"uuid": "8a2dda54-7737-47d5-82f8-ae2431bf65a0", "name": "", "x": 38.7018668128423, "y": -122.38282546368364, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "23861598-ab3c-4648-9de9-3ee4316f2cb4", "name": "p1rdm69", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8a2dda54-7737-47d5-82f8-ae2431bf65a0"}}}}, {"uuid": "9e951376-bb88-44f2-a35f-e171716fdd96", "name": "", "x": 38.701495649868505, "y": -122.3825066502607, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3e00fd9b-92b3-49c4-bcc2-957b9d2c7bad", "name": "p1rlv65", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9e951376-bb88-44f2-a35f-e171716fdd96"}}}}, {"uuid": "84576a85-50a9-45c2-ab04-9bd1cad70427", "name": "", "x": 38.701815325965796, "y": -122.38044139197483, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6a4fb658-c3ba-428a-82bf-b38ae68dd908", "name": "p1rdt36lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "84576a85-50a9-45c2-ab04-9bd1cad70427"}}}}, {"uuid": "38e99712-7679-4054-95fa-2634f8c37d8a", "name": "", "x": 38.701925218075054, "y": -122.38023741663469, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8300f90c-9a3b-400d-af04-072125dce84f", "name": "p1rlv63", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "38e99712-7679-4054-95fa-2634f8c37d8a"}}}}, {"uuid": "5f6775b3-6eb9-4eae-a0a4-44ca49b16b7e", "name": "", "x": 38.70179061086173, "y": -122.38718468697783, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "074f23bd-2fb2-4480-ae4b-f1c1f754613e", "name": "p1rdm71", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5f6775b3-6eb9-4eae-a0a4-44ca49b16b7e"}}}}, {"uuid": "9a15968a-34bf-40cb-9cbf-7467e5fd4b46", "name": "", "x": 38.70156139001374, "y": -122.38697566423983, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5efd07ee-012a-40a4-97bb-07c1a5ed898c", "name": "p1rlv64", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9a15968a-34bf-40cb-9cbf-7467e5fd4b46"}}}}, {"uuid": "96e3b526-172d-4c2c-aefc-89b5cea154dc", "name": "", "x": 38.7020086293725, "y": -122.38751633252258, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "590e467f-47a6-4c7e-ae3a-83cec8dd87e3", "name": "p1rdm72", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "96e3b526-172d-4c2c-aefc-89b5cea154dc"}}}}, {"uuid": "0997e9e0-7e96-449d-bbc7-a790b2928a00", "name": "", "x": 38.7022335504919, "y": -122.38744541239329, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3fcd1ee-e6e0-4ca3-aacf-cc527b07482a", "name": "p1rlv162", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0997e9e0-7e96-449d-bbc7-a790b2928a00"}}}}, {"uuid": "437cad19-f247-4f11-a9b0-8298d9bda0d4", "name": "", "x": 38.701696448473875, "y": -122.3875919728995, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "90a16370-67f7-4abd-992c-990d1eb8f17e", "name": "p1rdt37lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "437cad19-f247-4f11-a9b0-8298d9bda0d4"}}}}, {"uuid": "e106eb24-7a01-47e1-a694-69754915affd", "name": "", "x": 38.7014985369188, "y": -122.38819919157115, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35807695-5d6d-4544-a748-a96c56b705d1", "name": "p1rdm73", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e106eb24-7a01-47e1-a694-69754915affd"}}}}, {"uuid": "626c124b-2053-457c-ab89-54c6053f1645", "name": "", "x": 38.701670353304884, "y": -122.38831272923629, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6278f6ee-7332-4de8-9d2c-83bb637f489f", "name": "p1rlv457", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "626c124b-2053-457c-ab89-54c6053f1645"}}}}, {"uuid": "5493f5af-7894-49fc-9333-23343effb6c7", "name": "", "x": 38.70178443656836, "y": -122.37918061552492, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "352f8404-f923-468a-92a5-1be2f82ffb97", "name": "p1rdm74", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5493f5af-7894-49fc-9333-23343effb6c7"}}}}, {"uuid": "421b72f0-1f89-4f6c-a02b-5fd568cf930e", "name": "", "x": 38.701833201230905, "y": -122.37934517294276, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e90eb8a2-5db0-4861-96ef-a6991a0386eb", "name": "p1rlv66", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "421b72f0-1f89-4f6c-a02b-5fd568cf930e"}}}}, {"uuid": "33e19b23-b8c7-42b8-babb-ef9a8fd5ed1a", "name": "", "x": 38.701967149573, "y": -122.37911401099093, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "752aca33-7682-4e8c-a8b1-624467e02958", "name": "p1rdt38lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "33e19b23-b8c7-42b8-babb-ef9a8fd5ed1a"}}}}, {"uuid": "4c76e541-3e5a-43d7-aaa5-8196b790733b", "name": "", "x": 38.70235732979096, "y": -122.37866677526797, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2332f175-22ca-4894-b63d-246f5c11c572", "name": "p1rdm75", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c76e541-3e5a-43d7-aaa5-8196b790733b"}}}}, {"uuid": "f32f7bc5-6f90-4089-bec7-957167f1b819", "name": "", "x": 38.70211516673608, "y": -122.37867174586772, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c22aa2c8-a6fc-4b27-a875-e07e3f50ecac", "name": "p1rlv68", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f32f7bc5-6f90-4089-bec7-957167f1b819"}}}}, {"uuid": "da3b2612-960a-4760-b9db-3d1126101c02", "name": "", "x": 38.70178670019972, "y": -122.38549505637238, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "131099af-6f69-4531-bebf-e457ff5d7624", "name": "p1rdm76", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "da3b2612-960a-4760-b9db-3d1126101c02"}}}}, {"uuid": "c4fc819d-a932-4943-a7a8-b0008212d9bb", "name": "", "x": 38.701430782199786, "y": -122.38558924083848, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "876ffb0b-f33c-45b2-a085-7b34103ecffc", "name": "p1rlv69", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c4fc819d-a932-4943-a7a8-b0008212d9bb"}}}}, {"uuid": "0c79e619-8b46-4eb9-bbc3-ee2b7d368108", "name": "", "x": 38.701700119673376, "y": -122.38533518862636, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "623ec6b4-cb70-4437-9d79-5ec577bc3199", "name": "p1rdt39lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0c79e619-8b46-4eb9-bbc3-ee2b7d368108"}}}}, {"uuid": "8d15705c-b29e-458e-bd87-cc5cf3dbeb93", "name": "", "x": 38.70169870333672, "y": -122.38512694165256, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a909c826-1682-47f0-926c-0a67c9ff2a3a", "name": "p1rdm77", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8d15705c-b29e-458e-bd87-cc5cf3dbeb93"}}}}, {"uuid": "64ec693c-962c-4b4a-9a29-91692e5a3162", "name": "", "x": 38.701429210818716, "y": -122.38529025109813, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e53e7714-06d1-4f85-89c5-f152629e8ab7", "name": "p1rlv70", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "64ec693c-962c-4b4a-9a29-91692e5a3162"}}}}, {"uuid": "2e095ced-7dff-4118-9fbf-14b823e34b71", "name": "", "x": 38.6940139373904, "y": -122.37587462456409, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0d08444c-79a3-4ba0-8c69-1855a600dea0", "name": "p1rdt40lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2e095ced-7dff-4118-9fbf-14b823e34b71"}}}}, {"uuid": "0528c2c9-59dc-445a-bef7-3c20da20571c", "name": "", "x": 38.694063719222605, "y": -122.37569816102457, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "46cd88d0-b2c4-492a-af3d-d9ae886d0089", "name": "p1rlv143", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0528c2c9-59dc-445a-bef7-3c20da20571c"}}}}, {"uuid": "8b6a46f9-678f-4bdb-a630-5ce3f058dd3c", "name": "", "x": 38.69389087842103, "y": -122.37592566558304, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "435b1814-b0a6-40e3-a446-efe5b7fce133", "name": "p1rdm78", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8b6a46f9-678f-4bdb-a630-5ce3f058dd3c"}}}}, {"uuid": "a236f6f0-a10f-4bf6-a548-7064bf59a629", "name": "", "x": 38.69394647992354, "y": -122.3762126554526, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d7791de-0cf6-4901-8b95-2d67870f09f5", "name": "p1rlv71", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a236f6f0-a10f-4bf6-a548-7064bf59a629"}}}}, {"uuid": "f171115a-d335-42de-bb3e-cf5763cbcfa4", "name": "", "x": 38.69007704448215, "y": -122.37273530129958, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "793d0bf4-4d9f-4df4-bc95-d528dd7d31d5", "name": "p1rdt41lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f171115a-d335-42de-bb3e-cf5763cbcfa4"}}}}, {"uuid": "856fb6a1-3188-4dd5-8c7a-893d5944fa36", "name": "", "x": 38.68993682745413, "y": -122.37294747048301, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fc710fc3-ae5f-478e-997b-85467db7c93c", "name": "p1rlv72", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "856fb6a1-3188-4dd5-8c7a-893d5944fa36"}}}}, {"uuid": "a8e4f13a-5f5a-476e-b077-18b4f9da8bd1", "name": "", "x": 38.69017871415686, "y": -122.37268089773576, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "188047cd-3f14-4240-91fe-30113d48152b", "name": "p1rlv88", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8e4f13a-5f5a-476e-b077-18b4f9da8bd1"}}}}, {"uuid": "f760aebd-d2f9-4cdb-b451-2aba7e341a70", "name": "", "x": 38.69058527350743, "y": -122.3740266335316, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8fb27dc9-b404-49d1-84dd-0cde418b037d", "name": "p1rdt42lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f760aebd-d2f9-4cdb-b451-2aba7e341a70"}}}}, {"uuid": "cc1fe186-7eff-40cc-9087-6a08b3f0ffe7", "name": "", "x": 38.69045558452261, "y": -122.37389730590256, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "540e0121-fc39-4c2c-9fbc-012c020f5994", "name": "p1rlv86", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc1fe186-7eff-40cc-9087-6a08b3f0ffe7"}}}}, {"uuid": "d3dae137-37c2-4439-a8f7-287d04577a69", "name": "", "x": 38.690475022656685, "y": -122.3741615988237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c5f4300c-037f-42b5-a390-31ec1e8396b3", "name": "p1rdm82", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d3dae137-37c2-4439-a8f7-287d04577a69"}}}}, {"uuid": "ef7eaa33-52e1-434c-ab86-e12bd472fcf6", "name": "", "x": 38.69028492385651, "y": -122.37400227840031, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f4e2991c-1404-44da-bbb5-5a2ebc43bde4", "name": "p1rlv73", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef7eaa33-52e1-434c-ab86-e12bd472fcf6"}}}}, {"uuid": "9138a962-fd56-4f0f-8b21-acd66f15530f", "name": "", "x": 38.69038564798742, "y": -122.37430035768564, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5696ebea-257d-4cc1-9ae4-61c98563b706", "name": "p1rdm86", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9138a962-fd56-4f0f-8b21-acd66f15530f"}}}}, {"uuid": "dbb08176-39c0-4dbc-bf74-460d00d2f441", "name": "", "x": 38.690005204334135, "y": -122.37393572632347, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "afc70b80-ab76-440c-b05b-149458051675", "name": "p1rlv108", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dbb08176-39c0-4dbc-bf74-460d00d2f441"}}}}, {"uuid": "493507a6-2031-493a-ad6b-ef369cb0a201", "name": "", "x": 38.690672040311505, "y": -122.37392991440464, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "49a07eb5-9c9b-479c-a345-b09f72725a21", "name": "p1rdm83", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "493507a6-2031-493a-ad6b-ef369cb0a201"}}}}, {"uuid": "2233f4a7-d806-4388-900b-9d41df1e287d", "name": "", "x": 38.69071765074636, "y": -122.37403300248825, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0ef51371-3fa2-400a-a2b4-3afa97ff2419", "name": "p1rlv75", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2233f4a7-d806-4388-900b-9d41df1e287d"}}}}, {"uuid": "021c8fa6-1ab5-4a3b-b913-398dd6563305", "name": "", "x": 38.69090781102859, "y": -122.374203821834, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c5c96953-6710-4765-b5bd-4359e03e4c63", "name": "p1rlv130", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "021c8fa6-1ab5-4a3b-b913-398dd6563305"}}}}, {"uuid": "04e8ac20-3f95-4330-ad5d-f2b52e4280e4", "name": "", "x": 38.690788633118785, "y": -122.37382541248327, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ae45c08d-f629-4ff9-9c23-838b6e34da88", "name": "p1rdm84", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "04e8ac20-3f95-4330-ad5d-f2b52e4280e4"}}}}, {"uuid": "a8c38f40-05f1-4874-8046-4003ead1c4b8", "name": "", "x": 38.69085275864737, "y": -122.37402032667815, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e4dd2283-6100-48ce-b4bc-0e37b7b4e409", "name": "p1rlv79", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8c38f40-05f1-4874-8046-4003ead1c4b8"}}}}, {"uuid": "6c2fe5a3-78de-415f-9829-d2fa73ee39cb", "name": "", "x": 38.6908423930519, "y": -122.37376745173289, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d93360fa-3106-4444-9488-e73c6997ab71", "name": "p1rdm87", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c2fe5a3-78de-415f-9829-d2fa73ee39cb"}}}}, {"uuid": "59650fe8-d7a3-4405-94bf-13ea9d2f0b8e", "name": "", "x": 38.69085830065978, "y": -122.37390131828276, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "919a48e8-b378-4dd5-8e33-a2602fb58bc0", "name": "p1rlv115", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59650fe8-d7a3-4405-94bf-13ea9d2f0b8e"}}}}, {"uuid": "ca498dfc-d663-4237-a8fa-b38fa64f72e5", "name": "", "x": 38.6907528455112, "y": -122.37219295067007, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b812c54c-1689-47cf-beba-55faea943380", "name": "p1rdm90", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ca498dfc-d663-4237-a8fa-b38fa64f72e5"}}}}, {"uuid": "3eae7d71-071a-434a-936e-6fdec158239c", "name": "", "x": 38.69077167044301, "y": -122.37234226546438, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8e6de569-7f61-439e-a402-850c4f071ab3", "name": "p1rlv117", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3eae7d71-071a-434a-936e-6fdec158239c"}}}}, {"uuid": "0268316d-2bf7-483d-9aa8-55b9a7921399", "name": "", "x": 38.69123428534169, "y": -122.37237669444208, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "274aa0ec-f229-454c-b52d-23130bacb97e", "name": "p1rdt43lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0268316d-2bf7-483d-9aa8-55b9a7921399"}}}}, {"uuid": "3c4120d9-5325-4f01-8812-99a68d778116", "name": "", "x": 38.69134864004529, "y": -122.37238321787136, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0c82df28-72fa-4cf0-a844-8a6bf90e548b", "name": "p1rdm91", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3c4120d9-5325-4f01-8812-99a68d778116"}}}}, {"uuid": "4b05856f-25b9-4d86-8769-f887c528efb3", "name": "", "x": 38.691310990079565, "y": -122.37208458594603, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "54ca5205-5b71-42f2-8e24-c24f768a7a5c", "name": "p1rlv137", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4b05856f-25b9-4d86-8769-f887c528efb3"}}}}, {"uuid": "e736d97a-899f-460c-8076-87e1284f06d6", "name": "", "x": 38.69147492155732, "y": -122.37240511152062, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "acbf36c3-9c53-417f-98c1-fa1b5d4b60f4", "name": "p1rdm89", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e736d97a-899f-460c-8076-87e1284f06d6"}}}}, {"uuid": "36cb466e-9a0d-404d-bb08-cbf2ab13e1cf", "name": "", "x": 38.69153009984452, "y": -122.37261160297146, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5861410e-9d6d-423e-b967-2f2af65610b8", "name": "p1rlv74", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "36cb466e-9a0d-404d-bb08-cbf2ab13e1cf"}}}}, {"uuid": "66056a0b-621e-4e55-bd59-a4d2a449b4ab", "name": "", "x": 38.68938630771864, "y": -122.37020536032335, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c813f8a2-226b-431d-a41a-195cf5e8b01a", "name": "p1rdt44lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "66056a0b-621e-4e55-bd59-a4d2a449b4ab"}}}}, {"uuid": "4d54cf4d-36c1-4945-87e0-3fd1a67d9930", "name": "", "x": 38.68939678035235, "y": -122.37025840439561, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3354497f-6de7-405d-9fca-a9c77463dc27", "name": "p1rlv76", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d54cf4d-36c1-4945-87e0-3fd1a67d9930"}}}}, {"uuid": "e60fd94a-3e00-42ec-9121-2277b286d677", "name": "", "x": 38.690057823403926, "y": -122.37534955818452, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a5151d03-c8b3-41f2-a2cd-743aa8ea0fea", "name": "p1rdm93", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e60fd94a-3e00-42ec-9121-2277b286d677"}}}}, {"uuid": "6aa6e8f9-2731-4404-98c5-2d662c4bad90", "name": "", "x": 38.690220088213884, "y": -122.37535964547071, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f88a22a3-7e6c-4fc5-a8f4-a08cdaa3f5d6", "name": "p1rlv77", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6aa6e8f9-2731-4404-98c5-2d662c4bad90"}}}}, {"uuid": "eb9baf82-ce99-4bd0-b3d6-0bd99fd767c6", "name": "", "x": 38.68996899986402, "y": -122.37559179451463, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4dece5f0-ab6c-40ed-9ec6-0b1377d19e78", "name": "p1rdm94", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eb9baf82-ce99-4bd0-b3d6-0bd99fd767c6"}}}}, {"uuid": "e0a75be7-9eaf-4cdf-895a-1fe48b985539", "name": "", "x": 38.69013175574531, "y": -122.37569386454011, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ee33d90b-2f70-4c9d-863d-6486b95280b8", "name": "p1rlv119", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e0a75be7-9eaf-4cdf-895a-1fe48b985539"}}}}, {"uuid": "f33811d4-8e5e-4b75-98e4-e9e3ee105acd", "name": "", "x": 38.69009885909427, "y": -122.37512675776652, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e276abc-bb27-47e4-9de8-adaccbf964dd", "name": "p1rdt45lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f33811d4-8e5e-4b75-98e4-e9e3ee105acd"}}}}, {"uuid": "68d8f819-82c6-4f68-9d22-add5ca1a825e", "name": "", "x": 38.690225535592255, "y": -122.37469269533909, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a363b9b6-b80f-42cf-942e-17e723376ae6", "name": "p1rdm95", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "68d8f819-82c6-4f68-9d22-add5ca1a825e"}}}}, {"uuid": "1a0ff510-44f5-4e40-bac9-94d0f3d35467", "name": "", "x": 38.690035314507966, "y": -122.37451037852996, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "41960437-e2e6-4746-89c2-81c81602ca1b", "name": "p1rlv132", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1a0ff510-44f5-4e40-bac9-94d0f3d35467"}}}}, {"uuid": "c13588a5-fd65-4f01-ae00-29a3387c1182", "name": "", "x": 38.69396497728804, "y": -122.37461414459213, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2e93e7ed-6686-4fb2-8410-867f2cdbdab2", "name": "p1rdm96", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c13588a5-fd65-4f01-ae00-29a3387c1182"}}}}, {"uuid": "6c7ef76f-bde8-48eb-ad13-be3a39952c52", "name": "", "x": 38.69396985964566, "y": -122.37499754256292, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ae76f058-b79a-4c0f-90be-f9cd7a02bcfc", "name": "p1rlv78", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c7ef76f-bde8-48eb-ad13-be3a39952c52"}}}}, {"uuid": "05ef71ac-c109-4339-afed-73fc1b83ea7f", "name": "", "x": 38.694118107766265, "y": -122.3746013122857, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fdd576f2-a7e2-46eb-b2b0-818c4a97e694", "name": "p1rdm97", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "05ef71ac-c109-4339-afed-73fc1b83ea7f"}}}}, {"uuid": "c48aa8da-1798-4362-b5b7-73a858fb724c", "name": "", "x": 38.69415593578412, "y": -122.37493445252295, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "46ee0e6c-daf7-4412-94a7-5332a6a97656", "name": "p1rlv87", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c48aa8da-1798-4362-b5b7-73a858fb724c"}}}}, {"uuid": "b54fc4bd-352b-4d49-b123-d8ec37be6db1", "name": "", "x": 38.69382389629988, "y": -122.3746653446421, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aacdcb46-43e3-4147-ac25-3a9c1223e13a", "name": "p1rdt46lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b54fc4bd-352b-4d49-b123-d8ec37be6db1"}}}}, {"uuid": "e2d6efe2-38ba-4c3b-b704-9868be4eaae7", "name": "", "x": 38.69332609771847, "y": -122.37479218972346, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "70024d6c-94dd-4367-aeec-92d4bc5eec04", "name": "p1rdm98", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e2d6efe2-38ba-4c3b-b704-9868be4eaae7"}}}}, {"uuid": "948b06e4-a51d-4cd8-9bbb-9811f9996cee", "name": "", "x": 38.69336355649941, "y": -122.37505633665255, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ea9e5f8c-8477-403c-9d3a-911c4e5ab5c8", "name": "p1rlv138", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "948b06e4-a51d-4cd8-9bbb-9811f9996cee"}}}}, {"uuid": "f5d7283b-3a19-4218-880f-573c260dbb07", "name": "", "x": 38.69221243814819, "y": -122.3732880387573, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f031530a-b3fc-4f8e-b0ac-139009d1256c", "name": "p1rdt47lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5d7283b-3a19-4218-880f-573c260dbb07"}}}}, {"uuid": "9763b498-7e70-4ea0-9f4b-4bcd8a123c33", "name": "", "x": 38.692092560795636, "y": -122.3733081060302, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ab7e1b4a-f8ec-4211-b7a0-d7f9057f576a", "name": "p1rlv80", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9763b498-7e70-4ea0-9f4b-4bcd8a123c33"}}}}, {"uuid": "3ebad1dc-7b5d-4af3-8e2f-3e90cf714ce3", "name": "", "x": 38.69236265310078, "y": -122.37325975482375, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "db8f484a-94d5-4d20-8ebf-6708b1601a0d", "name": "p1rlv92", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3ebad1dc-7b5d-4af3-8e2f-3e90cf714ce3"}}}}, {"uuid": "29dc9d0c-aa67-46c7-9211-3b7d980cf123", "name": "", "x": 38.69245991415173, "y": -122.3717601018108, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2f1790fe-a399-46e3-b9e3-5979837777ce", "name": "p1rdt48lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "29dc9d0c-aa67-46c7-9211-3b7d980cf123"}}}}, {"uuid": "74ea0e90-f021-45c2-985c-a3cb88385ae9", "name": "", "x": 38.69259843146321, "y": -122.37185485582063, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ef92e40c-fe3c-4f7f-b844-884e1079e491", "name": "p1rlv81", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "74ea0e90-f021-45c2-985c-a3cb88385ae9"}}}}, {"uuid": "ed97c978-5fd5-4907-ba53-bcb6fa43fb14", "name": "", "x": 38.69231864911266, "y": -122.37177681198607, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a02925cd-7c5b-475f-9e91-30d639bb3c33", "name": "p1rlv120", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ed97c978-5fd5-4907-ba53-bcb6fa43fb14"}}}}, {"uuid": "7335310a-682c-4c5b-b04f-96fb5d0bacdd", "name": "", "x": 38.6924795549249, "y": -122.37153393231236, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fd7286c0-4c57-435f-bed2-fd9a927de8cc", "name": "p1rdm103", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7335310a-682c-4c5b-b04f-96fb5d0bacdd"}}}}, {"uuid": "240896b9-48a3-485b-afb2-209b3f5be2ac", "name": "", "x": 38.69255749370678, "y": -122.3714717809419, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4b02739e-d082-4c54-8deb-8ccc83ab82ab", "name": "p1rlv122", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "240896b9-48a3-485b-afb2-209b3f5be2ac"}}}}, {"uuid": "ed627fe4-0241-47e2-8e66-d0911edf3483", "name": "", "x": 38.693056440809926, "y": -122.37376716989863, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1e5bcc7e-f35c-4bbf-a7ff-a82817488b11", "name": "p1rdt49lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ed627fe4-0241-47e2-8e66-d0911edf3483"}}}}, {"uuid": "9c7705ad-1ce1-4efa-8baa-ac126fb5596d", "name": "", "x": 38.69309336879344, "y": -122.37340286288783, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "da2538bd-189b-4699-823b-ed459d94b422", "name": "p1rlv146", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9c7705ad-1ce1-4efa-8baa-ac126fb5596d"}}}}, {"uuid": "ff84e052-dc91-47d5-bf3f-d8465156a1f6", "name": "", "x": 38.693365493783084, "y": -122.37373395481842, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2409ced2-7817-40af-951f-33d725e9d75a", "name": "p1rdm104", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ff84e052-dc91-47d5-bf3f-d8465156a1f6"}}}}, {"uuid": "7fab99d1-39c7-4a67-a26a-a490bd18a53e", "name": "", "x": 38.69333125539768, "y": -122.3735427494079, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c3ddd704-2530-4392-8e9e-06e047b12f41", "name": "p1rlv82", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7fab99d1-39c7-4a67-a26a-a490bd18a53e"}}}}, {"uuid": "34c1c8cf-98d9-40f7-b221-800f7416fd25", "name": "", "x": 38.69285166538173, "y": -122.3737039387965, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a8385921-c183-4c26-bc99-bf5f0364c18b", "name": "p1rdm105", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "34c1c8cf-98d9-40f7-b221-800f7416fd25"}}}}, {"uuid": "559f04ef-a41b-4fc7-a97a-f8206ab479b3", "name": "", "x": 38.69285080314527, "y": -122.3735429639113, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "096e92a6-ea34-435e-a059-57d5234e1654", "name": "p1rlv107", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "559f04ef-a41b-4fc7-a97a-f8206ab479b3"}}}}, {"uuid": "af091acb-e936-456d-99d0-a49daa8431ea", "name": "", "x": 38.69316443073551, "y": -122.37605094152133, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8208c617-caa9-46a5-b28a-8a5b0d9898a2", "name": "p1rdt50lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "af091acb-e936-456d-99d0-a49daa8431ea"}}}}, {"uuid": "e529b33c-2b5c-4d79-84c2-a61b3b4aecc8", "name": "", "x": 38.69310634340839, "y": -122.3758289932297, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6ae7b1fe-08c4-4848-867e-e2426a325a99", "name": "p1rlv127", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e529b33c-2b5c-4d79-84c2-a61b3b4aecc8"}}}}, {"uuid": "f47c80f2-4d96-4104-a074-926b1622c44f", "name": "", "x": 38.69329674648888, "y": -122.37604581609166, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7948c980-abf7-4357-9ff8-4be9122a3167", "name": "p1rdm107", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f47c80f2-4d96-4104-a074-926b1622c44f"}}}}, {"uuid": "65d557de-e7d9-4492-96b2-9b1bf64cbb04", "name": "", "x": 38.69321156388965, "y": -122.37581260405913, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "24c3e8d8-1520-4a05-84af-a70da6140b4d", "name": "p1rlv83", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65d557de-e7d9-4492-96b2-9b1bf64cbb04"}}}}, {"uuid": "ff8cd1ac-4285-4784-8478-d357b8b3d1ce", "name": "", "x": 38.69331611852453, "y": -122.37629862181807, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6184fe8d-ae60-426a-8c0c-a3cc56c5b67e", "name": "p1rlv123", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ff8cd1ac-4285-4784-8478-d357b8b3d1ce"}}}}, {"uuid": "a9bb9f0a-c1ee-4814-8831-4afd88339097", "name": "", "x": 38.692999373711416, "y": -122.37604839940005, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c2deeb6a-3ea7-44d9-9ee0-b013733dadc4", "name": "p1rdm110", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a9bb9f0a-c1ee-4814-8831-4afd88339097"}}}}, {"uuid": "c03cc8c8-a4ae-4a69-bea0-b62060e3309c", "name": "", "x": 38.692941715957275, "y": -122.37590693919702, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cbdefe7a-517b-495b-88b8-dcf15a9429ff", "name": "p1rlv135", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c03cc8c8-a4ae-4a69-bea0-b62060e3309c"}}}}, {"uuid": "be69abca-c06f-493d-baf9-5ac7009a85d4", "name": "", "x": 38.692481049048034, "y": -122.37128492416231, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "09d7f030-a9b4-4705-82af-6cf140ba64d1", "name": "p1rdt51lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be69abca-c06f-493d-baf9-5ac7009a85d4"}}}}, {"uuid": "462dc74b-1c9a-44f1-a2d7-8681441fa9d6", "name": "", "x": 38.69252947996807, "y": -122.37076308321973, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "55e7538f-4bde-4810-a237-ac0cad7ba805", "name": "p1rlv84", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "462dc74b-1c9a-44f1-a2d7-8681441fa9d6"}}}}, {"uuid": "de0ee001-0810-4d03-9b34-91f9ab41b7cb", "name": "", "x": 38.6922695134408, "y": -122.37101833090937, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0060c029-188f-4725-a935-8d0d9cc892f7", "name": "p1rlv93", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "de0ee001-0810-4d03-9b34-91f9ab41b7cb"}}}}, {"uuid": "a39ff69c-ac92-4842-90cc-f3461b549300", "name": "", "x": 38.69210249623662, "y": -122.37348049869223, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a5dd2d9f-42d5-48c4-b1e1-34ae6aa555df", "name": "p1rdm113", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a39ff69c-ac92-4842-90cc-f3461b549300"}}}}, {"uuid": "90a4515d-a43d-4958-b510-8804455e348b", "name": "", "x": 38.69211341663018, "y": -122.37383686081611, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dcc52dd9-bacb-4e49-a057-d3747f89a7f7", "name": "p1rlv85", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "90a4515d-a43d-4958-b510-8804455e348b"}}}}, {"uuid": "3871a0c1-a5e7-4f51-9ba1-836ee2375900", "name": "", "x": 38.69236400854256, "y": -122.37351271362792, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f42789f3-35c3-4d0d-adda-2044adce92c0", "name": "p1rdm114", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3871a0c1-a5e7-4f51-9ba1-836ee2375900"}}}}, {"uuid": "96de4a8f-3d07-40c8-9322-a027d76c4048", "name": "", "x": 38.69234050594775, "y": -122.37364337983433, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6a1f01bc-d1f1-4d92-b1e2-1f8223624c52", "name": "p1rlv91", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "96de4a8f-3d07-40c8-9322-a027d76c4048"}}}}, {"uuid": "5f73ddf1-4313-4186-92b7-7545d7cb1de3", "name": "", "x": 38.691649262567026, "y": -122.37351497173694, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c70a7331-8c41-4370-b053-3eae432d52ae", "name": "p1rdt52lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5f73ddf1-4313-4186-92b7-7545d7cb1de3"}}}}, {"uuid": "8bbf286f-4457-45c4-a843-ea91d2a17f4d", "name": "", "x": 38.691390973585875, "y": -122.37355569590474, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d2d46cd2-9caf-47a7-b134-a29fccd91b9c", "name": "p1rdm115", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8bbf286f-4457-45c4-a843-ea91d2a17f4d"}}}}, {"uuid": "3cc3de65-5492-4f37-9a52-c57850ceb521", "name": "", "x": 38.691389371784915, "y": -122.37325674863969, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "db2d4080-1f43-47a3-9f3a-e25d1e4f5076", "name": "p1rlv94", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3cc3de65-5492-4f37-9a52-c57850ceb521"}}}}, {"uuid": "dc46f775-942e-4b57-a70e-ebee5a398f00", "name": "", "x": 38.69141053564886, "y": -122.3738429881131, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "85afc796-3fe5-4027-b84e-10d502124636", "name": "p1rlv103", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dc46f775-942e-4b57-a70e-ebee5a398f00"}}}}, {"uuid": "9f9870ad-18ce-4f8e-aafd-27e9a5ce0884", "name": "", "x": 38.691455037994594, "y": -122.373739113497, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4b7dbf54-f6bc-4e20-b2f3-8c63a44dd993", "name": "p1rlv144", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9f9870ad-18ce-4f8e-aafd-27e9a5ce0884"}}}}, {"uuid": "d1dd480a-e298-46fc-bde3-865df51decce", "name": "", "x": 38.69127394993667, "y": -122.37357971347488, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a0d6e82b-cba7-4c7e-8715-d73c3530bad7", "name": "p1rdm116", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1dd480a-e298-46fc-bde3-865df51decce"}}}}, {"uuid": "fd74d192-e637-48d7-8d35-d8fbaeb298f5", "name": "", "x": 38.691299813396455, "y": -122.37336101652306, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "82f19d5c-0941-411d-8baa-3ba029471dae", "name": "p1rlv98", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fd74d192-e637-48d7-8d35-d8fbaeb298f5"}}}}, {"uuid": "b6cdcfae-cff8-4e49-ad15-f9b8de0e80f3", "name": "", "x": 38.69128456220349, "y": -122.37387858172916, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b45d086e-8e0d-42f4-a8ec-6d3a9579a96b", "name": "p1rlv136", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b6cdcfae-cff8-4e49-ad15-f9b8de0e80f3"}}}}, {"uuid": "8ddc7d7f-da7a-419c-9197-b4d0540b8ba5", "name": "", "x": 38.69265743519212, "y": -122.37614335951521, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "329f78a6-af13-4ceb-bc87-4660d497c22e", "name": "p1rdm122", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8ddc7d7f-da7a-419c-9197-b4d0540b8ba5"}}}}, {"uuid": "10bc977a-803e-4f0f-ba15-de1ba41eb822", "name": "", "x": 38.69254776576972, "y": -122.37585684466497, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d3367cc2-b096-4cfb-ae71-038eb9e06b46", "name": "p1rlv125", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10bc977a-803e-4f0f-ba15-de1ba41eb822"}}}}, {"uuid": "ce535576-0e9b-4e7c-b655-cde66068e7df", "name": "", "x": 38.692649343871935, "y": -122.37631591047503, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aa8af0a4-4d55-41e4-83d1-4fe349920e38", "name": "p1rlv148", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ce535576-0e9b-4e7c-b655-cde66068e7df"}}}}, {"uuid": "911b88f2-844c-45e2-ae9a-b20256b0016c", "name": "", "x": 38.69275631408947, "y": -122.37609650577265, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8d595142-3854-4152-b64a-6cda8396a523", "name": "p1rdm121", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "911b88f2-844c-45e2-ae9a-b20256b0016c"}}}}, {"uuid": "c13e3655-f460-4dd1-aecb-af05f8e64a35", "name": "", "x": 38.69270022130948, "y": -122.3757175352468, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "66748ae6-b6ef-4228-bb0f-f9a121f0e1a3", "name": "p1rlv111", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c13e3655-f460-4dd1-aecb-af05f8e64a35"}}}}, {"uuid": "341b2db8-4359-479b-94c7-4683b22cf69d", "name": "", "x": 38.692882349552875, "y": -122.37607241348934, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e2e27276-ea6c-40a3-92d3-4648ec9d235d", "name": "p1rdm123", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "341b2db8-4359-479b-94c7-4683b22cf69d"}}}}, {"uuid": "6513d061-1878-4780-8a4f-3b4468228566", "name": "", "x": 38.692817981929934, "y": -122.37583149911002, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "499fb461-ccb6-436a-8078-eec9beffb4a9", "name": "p1rlv131", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6513d061-1878-4780-8a4f-3b4468228566"}}}}, {"uuid": "5305b25b-d732-4948-8e2a-120bdd4e9ee1", "name": "", "x": 38.69257937121657, "y": -122.37618250960169, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2536a0eb-a35c-40d4-9773-b78379e7481a", "name": "p1rdt53lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5305b25b-d732-4948-8e2a-120bdd4e9ee1"}}}}, {"uuid": "71836ddb-b0aa-495c-a6dd-453ad997e814", "name": "", "x": 38.69241474350349, "y": -122.3762604541736, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e9f62740-f47f-4c97-bae7-4380fe83fcbc", "name": "p1rdm124", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "71836ddb-b0aa-495c-a6dd-453ad997e814"}}}}, {"uuid": "0078fa0b-43fb-419f-bd42-e6fd99824e8f", "name": "", "x": 38.69237796229021, "y": -122.37612278955407, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eb69a6a9-3eaf-4fc3-82be-0eec77455a82", "name": "p1rlv141", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0078fa0b-43fb-419f-bd42-e6fd99824e8f"}}}}, {"uuid": "d7bb4578-cd1e-44b4-a117-fcfb149a76f4", "name": "", "x": 38.69212730175752, "y": -122.37643542970159, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d1071344-55a0-4684-9fbf-5729ec1f21c2", "name": "p1rdm120", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d7bb4578-cd1e-44b4-a117-fcfb149a76f4"}}}}, {"uuid": "f1b03aac-33b7-4dd4-9479-ae369e39696d", "name": "", "x": 38.692072620801916, "y": -122.37632091820853, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "24d75e9a-0249-48ca-ad10-32738bb6a519", "name": "p1rlv89", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f1b03aac-33b7-4dd4-9479-ae369e39696d"}}}}, {"uuid": "a53dd899-1fb1-46fd-b738-e94aa524e450", "name": "", "x": 38.690545533550726, "y": -122.37333707739843, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "57889d14-4aac-4aee-a9e2-677a047e8054", "name": "p1rdt54lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a53dd899-1fb1-46fd-b738-e94aa524e450"}}}}, {"uuid": "d58e8629-1002-48f1-8063-585740bce5a9", "name": "", "x": 38.690111985440346, "y": -122.3736818329642, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e06b2ac7-926e-4caf-afac-386910d4ea5e", "name": "p1rlv90", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d58e8629-1002-48f1-8063-585740bce5a9"}}}}, {"uuid": "e419a944-3cee-407a-af22-419361162c4c", "name": "", "x": 38.69031825985071, "y": -122.37349606102795, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4fe82ede-430d-454d-b9d0-e212d0621ea1", "name": "p1rlv105", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e419a944-3cee-407a-af22-419361162c4c"}}}}, {"uuid": "6f475d0a-f83e-4632-b565-29f42721ed71", "name": "", "x": 38.69409341663082, "y": -122.37388461682215, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "85ad3bf0-7e82-4e32-8106-faddcf725bdf", "name": "p1rdt56lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6f475d0a-f83e-4632-b565-29f42721ed71"}}}}, {"uuid": "20af2ea4-a9f6-4e7d-9cf0-b224359b9df0", "name": "", "x": 38.693962208985816, "y": -122.37409671723277, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "31508077-f731-47cb-94a9-869d7910e406", "name": "p1rlv96", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "20af2ea4-a9f6-4e7d-9cf0-b224359b9df0"}}}}, {"uuid": "a9937757-1991-4707-aad9-564a014df7a1", "name": "", "x": 38.694453827235925, "y": -122.37334499797639, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a60b127d-0530-495e-b3b9-2ebabf070fa1", "name": "p1rdm131", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a9937757-1991-4707-aad9-564a014df7a1"}}}}, {"uuid": "508ecc8e-1f06-4f5a-8b96-19bce68709b4", "name": "", "x": 38.69441870621642, "y": -122.37351778932282, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a11ba246-99d9-4cf5-a557-bec53c75e6fb", "name": "p1rlv804", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "508ecc8e-1f06-4f5a-8b96-19bce68709b4"}}}}, {"uuid": "c05965fd-98d6-49ab-b7ed-438036a0cab8", "name": "", "x": 38.69031197102896, "y": -122.37232328557447, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4bf5bf18-363d-4f4e-bf10-9ffc601c0f30", "name": "p1rdm133", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c05965fd-98d6-49ab-b7ed-438036a0cab8"}}}}, {"uuid": "16c92af6-c70a-4596-b4d0-70df593ccca4", "name": "", "x": 38.69039362804738, "y": -122.37242605719072, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bc4a448a-c6cb-4714-b8e6-b75bc6bc219c", "name": "p1rlv99", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "16c92af6-c70a-4596-b4d0-70df593ccca4"}}}}, {"uuid": "4c1aabbe-0b3e-4cb5-8d6c-f778f2aea5ba", "name": "", "x": 38.69048579257096, "y": -122.37227974908389, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e3367c40-9f47-42d9-b627-bc502b170f2a", "name": "p1rdt58lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c1aabbe-0b3e-4cb5-8d6c-f778f2aea5ba"}}}}, {"uuid": "d328a29f-ee37-4a80-a029-55b6cb1e5ea2", "name": "", "x": 38.69060891171015, "y": -122.37224020218359, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32e76273-c930-4506-9610-8cbfca04af67", "name": "p1rdm134", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d328a29f-ee37-4a80-a029-55b6cb1e5ea2"}}}}, {"uuid": "8a619225-2829-4897-911e-5c71a4d46e70", "name": "", "x": 38.69066464553883, "y": -122.37255017170527, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48d1be49-5aca-4e18-8b85-2a1274b3f26d", "name": "p1rlv101", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8a619225-2829-4897-911e-5c71a4d46e70"}}}}, {"uuid": "4e0e8d3c-7c65-411b-9610-d85c9d4654d5", "name": "", "x": 38.69344092722396, "y": -122.37604456356478, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a7b11b31-78f1-41fa-b511-df76daad0efc", "name": "p1rdm135", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4e0e8d3c-7c65-411b-9610-d85c9d4654d5"}}}}, {"uuid": "e138768b-008a-4552-b69b-4aa8538cf63a", "name": "", "x": 38.69344227667356, "y": -122.37629752630082, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "62a0d673-eaba-4032-9038-8095e2d53999", "name": "p1rlv100", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e138768b-008a-4552-b69b-4aa8538cf63a"}}}}, {"uuid": "fe421763-978a-4d59-8ddf-5f15b7e8f858", "name": "", "x": 38.69361499553134, "y": -122.37604702739569, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8aca9934-9439-4ce6-9ee3-475980324054", "name": "p1rdt59lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fe421763-978a-4d59-8ddf-5f15b7e8f858"}}}}, {"uuid": "1a258a18-33ff-49b6-af22-3f303a0cb210", "name": "", "x": 38.69374688178432, "y": -122.37596141343235, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a415176a-ddab-47a0-9ce7-54c53c4c0f11", "name": "p1rdm136", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1a258a18-33ff-49b6-af22-3f303a0cb210"}}}}, {"uuid": "20b67a46-6909-495f-95d4-ec7eeead6efe", "name": "", "x": 38.69371837494324, "y": -122.37568568791933, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0dbaab50-3abc-4207-82dc-5fcc5be68aad", "name": "p1rlv121", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "20b67a46-6909-495f-95d4-ec7eeead6efe"}}}}, {"uuid": "6ee52466-2ac9-43a0-afb5-55b532be96bf", "name": "", "x": 38.69088191916026, "y": -122.37220729684483, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d2517cea-05d3-4b7f-b9fc-0df0fde81235", "name": "p1rdt60lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6ee52466-2ac9-43a0-afb5-55b532be96bf"}}}}, {"uuid": "ebddd272-2642-4382-93c8-732a7e251cf7", "name": "", "x": 38.690940600905, "y": -122.3719153472003, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "06a432e3-dd37-4c52-b954-6652bb529c8e", "name": "p1rlv102", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ebddd272-2642-4382-93c8-732a7e251cf7"}}}}, {"uuid": "d34b3076-2883-4efd-a327-df823cfc09ce", "name": "", "x": 38.6914549432012, "y": -122.37540639973672, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e53344e0-e328-4acd-b159-e1f8cc246996", "name": "p1rdm138", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d34b3076-2883-4efd-a327-df823cfc09ce"}}}}, {"uuid": "65aeaed9-9c37-4058-be93-e0d605ed9fe2", "name": "", "x": 38.69137249020519, "y": -122.3751541495459, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c76c5b8f-1994-470c-a024-b97c73b9bb41", "name": "p1rlv104", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65aeaed9-9c37-4058-be93-e0d605ed9fe2"}}}}, {"uuid": "03b11a14-27fc-4ea8-843f-062716cd853d", "name": "", "x": 38.69120075557791, "y": -122.37558860981264, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "70f11a44-826f-45b8-9dc3-0f51ce6c9733", "name": "p1rdt61lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "03b11a14-27fc-4ea8-843f-062716cd853d"}}}}, {"uuid": "3143231f-7aee-4214-acd2-38fc402f9656", "name": "", "x": 38.69118822551713, "y": -122.37608712916376, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "022bda10-6b1a-408b-a231-adb63e189d14", "name": "p1rdm139", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3143231f-7aee-4214-acd2-38fc402f9656"}}}}, {"uuid": "13ab2b32-9d28-4487-81f1-93b0f2bdb41c", "name": "", "x": 38.691080519301316, "y": -122.37616855391688, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e5ca78b-6151-4a35-8a04-1bab215f0f10", "name": "p1rlv124", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "13ab2b32-9d28-4487-81f1-93b0f2bdb41c"}}}}, {"uuid": "8313fe5a-77d6-4a80-a7cd-5eef33ed7059", "name": "", "x": 38.693600768265796, "y": -122.37276202285804, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fac6d4e1-b14d-4973-9626-6a4bde2d2a42", "name": "p1rdt63lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8313fe5a-77d6-4a80-a7cd-5eef33ed7059"}}}}, {"uuid": "d428aee0-32db-49a7-b1b4-0ec78e144463", "name": "", "x": 38.69345061514859, "y": -122.37280180665408, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c76fc99c-c160-4ed0-85dd-ec3da962bb24", "name": "p1rlv109", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d428aee0-32db-49a7-b1b4-0ec78e144463"}}}}, {"uuid": "08ec40fb-604c-4457-9274-469a0579239f", "name": "", "x": 38.6932526134289, "y": -122.3728495309013, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25edc94b-a44b-4200-8cde-73941c2818b8", "name": "p1rlv112", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "08ec40fb-604c-4457-9274-469a0579239f"}}}}, {"uuid": "ed2e38b0-cdbf-45f9-9605-3518d40c2b3c", "name": "", "x": 38.69373045846697, "y": -122.37289135400576, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "21b14d95-6634-4f0e-a380-d5e57328d825", "name": "p1rdm143", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ed2e38b0-cdbf-45f9-9605-3518d40c2b3c"}}}}, {"uuid": "73fade0f-c897-4b49-8bd1-e189d59eef12", "name": "", "x": 38.69364972680421, "y": -122.37296105211496, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8b515111-3455-471a-aba8-92c82624a195", "name": "p1rlv139", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "73fade0f-c897-4b49-8bd1-e189d59eef12"}}}}, {"uuid": "b345efc1-ee77-4dc0-8990-db5453affdff", "name": "", "x": 38.6938583426107, "y": -122.37321220673307, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "09182ca9-8ea2-4d1c-9c3e-5850a77c1b66", "name": "p1rdm145", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b345efc1-ee77-4dc0-8990-db5453affdff"}}}}, {"uuid": "d8c833e7-f9ae-40b3-954e-fc43f94fe057", "name": "", "x": 38.69399264902756, "y": -122.37305004970418, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2756378a-0c67-47cf-969d-bdb9e55c8a4b", "name": "p1rlv113", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d8c833e7-f9ae-40b3-954e-fc43f94fe057"}}}}, {"uuid": "1fe742ec-1cfe-4dc9-bc90-282a353ece23", "name": "", "x": 38.69377761075648, "y": -122.37328190461031, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "56bc8935-c658-424c-83d8-0d13bf8d292a", "name": "p1rlv128", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1fe742ec-1cfe-4dc9-bc90-282a353ece23"}}}}, {"uuid": "4fc8e4df-cce5-4fd7-a029-1788d5853eb5", "name": "", "x": 38.694126443783816, "y": -122.37332088048717, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2ae9cb89-7cb8-48c6-a5bc-4178ee364ae8", "name": "p1rdt65lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4fc8e4df-cce5-4fd7-a029-1788d5853eb5"}}}}, {"uuid": "026d3939-bb21-4f6c-855c-b54a7898f18e", "name": "", "x": 38.694562147559466, "y": -122.3733785499152, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "de7551d6-5168-440c-8fe2-9f17e0904c29", "name": "p1rdm147", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "026d3939-bb21-4f6c-855c-b54a7898f18e"}}}}, {"uuid": "e11d221e-d445-4bf9-b913-3b02f6e74ea6", "name": "", "x": 38.69465084301279, "y": -122.37311329835559, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e7ffe87d-4424-4495-83c1-6765d385207c", "name": "p1rlv838", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e11d221e-d445-4bf9-b913-3b02f6e74ea6"}}}}, {"uuid": "9dfdfc2c-853e-4c2b-9385-252d60851f2d", "name": "", "x": 38.767616650522, "y": -122.38054158855523, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dfb9fa3b-c758-4c2e-bc51-f297b1ed21bf", "name": "p1rdt66lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9dfdfc2c-853e-4c2b-9385-252d60851f2d"}}}}, {"uuid": "2538c3eb-b1bc-4ee5-8b00-fa5f18ac8f48", "name": "", "x": 38.767590639077596, "y": -122.38049892417555, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d7934cd3-dcd6-4b67-8206-8a3636b6f75d", "name": "p1rlv114", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2538c3eb-b1bc-4ee5-8b00-fa5f18ac8f48"}}}}, {"uuid": "342627f1-23fc-4fc1-801a-3d315338bc32", "name": "", "x": 38.76719268838157, "y": -122.36058092984808, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bd2d6296-a302-4027-9e5f-c24a56a1a1ac", "name": "p1rdt68lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "342627f1-23fc-4fc1-801a-3d315338bc32"}}}}, {"uuid": "d877fb1b-68a6-4726-933b-8b5b97ff3748", "name": "", "x": 38.76717558814645, "y": -122.36126774194496, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "247e37b3-d6d0-41d7-a6b3-ee29d415da50", "name": "p1rlv118", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d877fb1b-68a6-4726-933b-8b5b97ff3748"}}}}, {"uuid": "da398a4c-6151-40cc-aced-2f61d4aa4fc6", "name": "", "x": 38.689974435374744, "y": -122.37228069359776, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7057debb-bd4d-4156-a253-0f3a14cdd784", "name": "p1rdt69lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "da398a4c-6151-40cc-aced-2f61d4aa4fc6"}}}}, {"uuid": "28269207-9ffd-447f-813e-276f53697dd2", "name": "", "x": 38.68985295036364, "y": -122.37243078084407, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c6c42586-4f46-45c6-910f-90fca771cfd2", "name": "p1rlv129", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "28269207-9ffd-447f-813e-276f53697dd2"}}}}, {"uuid": "750d9357-0219-4629-9238-6ea19caae837", "name": "", "x": 38.68983375524, "y": -122.37221248161097, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "47b7d9f8-ca72-4a77-af67-74ee561f7f10", "name": "p1rlv140", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "750d9357-0219-4629-9238-6ea19caae837"}}}}, {"uuid": "ef755cd7-5294-40c4-91c0-5cf1aacdfadb", "name": "", "x": 38.69318495516089, "y": -122.37483189069003, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "02440066-bc62-4629-96c5-4b497827de5b", "name": "p1rdt70lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef755cd7-5294-40c4-91c0-5cf1aacdfadb"}}}}, {"uuid": "35da9aa8-9637-4cb6-bec3-23001af4bfad", "name": "", "x": 38.69327375078167, "y": -122.3751146121051, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "31dc8280-eb14-4f87-85d7-8eae17013fe7", "name": "p1rlv133", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "35da9aa8-9637-4cb6-bec3-23001af4bfad"}}}}, {"uuid": "e492d455-8b95-4140-896e-122720e148d6", "name": "", "x": 38.69171296593506, "y": -122.37647352235795, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "43d5d2c5-10f6-4e89-91fa-5186f269b659", "name": "p1rdm155", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e492d455-8b95-4140-896e-122720e148d6"}}}}, {"uuid": "e65435ef-abb3-4ac1-89e5-c476f3b500f1", "name": "", "x": 38.69171223017465, "y": -122.37633554599886, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "425bdcfa-9753-4ef5-bb38-9e014ae779dc", "name": "p1rlv134", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e65435ef-abb3-4ac1-89e5-c476f3b500f1"}}}}, {"uuid": "23e3a742-b04c-4e8f-b57d-1ab749ef5509", "name": "", "x": 38.69147969326603, "y": -122.37638705727157, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e71f106d-4b41-405f-bce9-3d06b336a554", "name": "p1rdt71lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "23e3a742-b04c-4e8f-b57d-1ab749ef5509"}}}}, {"uuid": "7f986097-b809-478f-8770-78aac41b94ff", "name": "", "x": 38.69139677338097, "y": -122.37632678646379, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8357e543-eba0-4863-9d95-e34d84a3fae7", "name": "p1rdm156", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7f986097-b809-478f-8770-78aac41b94ff"}}}}, {"uuid": "7ee686cc-84ec-4ff3-9f8f-854f628ac999", "name": "", "x": 38.691395853444895, "y": -122.37615431677973, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1704e67-dfa3-4a6b-a3f4-7ebba9d27537", "name": "p1rlv145", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7ee686cc-84ec-4ff3-9f8f-854f628ac999"}}}}, {"uuid": "0431b8bc-cdf5-4f6e-b49c-eb912990b029", "name": "", "x": 38.69181140426288, "y": -122.37350205897214, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4b59eeab-d997-4186-ab59-0424644d5aeb", "name": "p1rdt72lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0431b8bc-cdf5-4f6e-b49c-eb912990b029"}}}}, {"uuid": "41d95e2a-ac27-4824-827e-3f927ed8ecc1", "name": "", "x": 38.6918879083499, "y": -122.37326787315344, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "070d9a60-c6f2-424c-bd0f-66c52d349f0c", "name": "p1rlv147", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "41d95e2a-ac27-4824-827e-3f927ed8ecc1"}}}}, {"uuid": "bcf6bf7b-ed30-4d11-94d5-a4e84b67a7c4", "name": "", "x": 38.70177173843472, "y": -122.38529743886787, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35f3fd4d-f962-4e4e-89d8-8b41a07ff57d", "name": "p1rdm158", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bcf6bf7b-ed30-4d11-94d5-a4e84b67a7c4"}}}}, {"uuid": "e036b17c-2c45-421a-a0ad-22e901b75472", "name": "", "x": 38.70192489270885, "y": -122.38529750774045, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "063e89ea-6dd0-404f-abfb-21686f3041ed", "name": "p1rlv149", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e036b17c-2c45-421a-a0ad-22e901b75472"}}}}, {"uuid": "dc1f28a1-6b0e-494c-9128-161bf7611a05", "name": "", "x": 38.701762667089824, "y": -122.38553586657494, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4f027d15-df82-4989-93e5-a3b40c862b08", "name": "p1rdt73lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dc1f28a1-6b0e-494c-9128-161bf7611a05"}}}}, {"uuid": "45cb53cc-d42e-45c1-8dea-12d137daf666", "name": "", "x": 38.7017739969935, "y": -122.38573580631073, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7b8d2667-d52b-46b3-ace4-2ad2b4e3050e", "name": "p1rdm159", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "45cb53cc-d42e-45c1-8dea-12d137daf666"}}}}, {"uuid": "ce5d58a5-24be-4e25-851b-2d3cc071d845", "name": "", "x": 38.70192743071094, "y": -122.38578049451348, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5187e006-621e-4c15-9604-0272ae62887c", "name": "p1rlv167", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ce5d58a5-24be-4e25-851b-2d3cc071d845"}}}}, {"uuid": "183e0605-103e-45e9-9163-63593da28942", "name": "", "x": 38.70203671550442, "y": -122.37747640223225, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bb4a799f-0e03-4ba6-b8ce-8f5e117fd2c2", "name": "p1rdm160", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "183e0605-103e-45e9-9163-63593da28942"}}}}, {"uuid": "b8296ec7-3cda-410c-8834-0221de56b03e", "name": "", "x": 38.70208317973028, "y": -122.37774050453031, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0b9979ec-4e43-4feb-a617-28191e9dd9d8", "name": "p1rlv150", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b8296ec7-3cda-410c-8834-0221de56b03e"}}}}, {"uuid": "9c87a630-51fc-447a-8893-3882b474b13b", "name": "", "x": 38.702169092358545, "y": -122.37748277827959, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "37880102-8a9c-4f7b-930a-b29a94241866", "name": "p1rdt74lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9c87a630-51fc-447a-8893-3882b474b13b"}}}}, {"uuid": "4e339b8e-d334-4e6e-b8b0-f354cfa78884", "name": "", "x": 38.70233414912363, "y": -122.37748532373683, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "243cdb10-5012-48b5-809f-1952913bf655", "name": "p1rdm161", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4e339b8e-d334-4e6e-b8b0-f354cfa78884"}}}}, {"uuid": "f5b304ee-ff90-4eae-9d5e-de243e25ae8c", "name": "", "x": 38.702308461860476, "y": -122.3777385521559, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0e326756-7ead-4099-a065-9f2de5693197", "name": "p1rlv169", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5b304ee-ff90-4eae-9d5e-de243e25ae8c"}}}}, {"uuid": "edb1309f-17be-473e-9536-b73605ba9cc7", "name": "", "x": 38.70182389972923, "y": -122.38611886200323, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "699bbf24-59ba-4dba-8bd4-1cf04a7e6e47", "name": "p1rdt75lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "edb1309f-17be-473e-9536-b73605ba9cc7"}}}}, {"uuid": "89e8b4bd-54f6-445d-98bc-cbfabb734b35", "name": "", "x": 38.70198343088721, "y": -122.38614802224237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "345b5c48-cd35-418e-bc08-50c06f5dff09", "name": "p1rlv151", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "89e8b4bd-54f6-445d-98bc-cbfabb734b35"}}}}, {"uuid": "fe33c8c8-9a84-4be4-9d3a-b3f0264e9519", "name": "", "x": 38.701353959316926, "y": -122.37840985382832, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4ecf2223-f120-45b4-8aab-a36d60161aec", "name": "p1rdt76lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fe33c8c8-9a84-4be4-9d3a-b3f0264e9519"}}}}, {"uuid": "8c23f4f5-3dcd-403e-892a-0178fb27e88f", "name": "", "x": 38.70149204336824, "y": -122.37842413503941, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5ccdfbc7-d3a6-4f74-ad32-25ff11a2e3b7", "name": "p1rlv154", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8c23f4f5-3dcd-403e-892a-0178fb27e88f"}}}}, {"uuid": "aeb979fd-4489-43fd-97d9-b0b766b3b211", "name": "", "x": 38.70130360088785, "y": -122.37857526759122, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0bd295ef-2c38-4c6b-915a-73900e920b92", "name": "p1rdm163", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aeb979fd-4489-43fd-97d9-b0b766b3b211"}}}}, {"uuid": "71b04380-49f0-49d3-b901-8a86282d5917", "name": "", "x": 38.70119454861773, "y": -122.37840371014978, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ebbe09dd-7560-4eff-9e32-803f14b4ce7c", "name": "p1rlv153", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "71b04380-49f0-49d3-b901-8a86282d5917"}}}}, {"uuid": "ca1e267b-7f14-4898-83f6-e667edcf4f24", "name": "", "x": 38.702363895820405, "y": -122.37852761379413, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3fd9bf7-ecdd-4dcb-966a-f426d5f2ee81", "name": "p1rdt77lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ca1e267b-7f14-4898-83f6-e667edcf4f24"}}}}, {"uuid": "b239dd78-4f54-4445-a01c-6bb955e0e274", "name": "", "x": 38.70251884097236, "y": -122.37832324388756, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2452d5af-5aba-4d4b-8cd9-27a95fe6b34d", "name": "p1rlv155", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b239dd78-4f54-4445-a01c-6bb955e0e274"}}}}, {"uuid": "447d14e7-4cba-4661-a6d7-a03c610b24ec", "name": "", "x": 38.70156690402656, "y": -122.3772504726202, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e110db24-1653-41b5-8496-821dfff05769", "name": "p1rdm166", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "447d14e7-4cba-4661-a6d7-a03c610b24ec"}}}}, {"uuid": "b80bc469-eb08-4031-91e6-8f576656fd95", "name": "", "x": 38.70172886217702, "y": -122.37720306729005, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7f607e6b-9540-4845-9f0c-6c334eb0e807", "name": "p1rlv156", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b80bc469-eb08-4031-91e6-8f576656fd95"}}}}, {"uuid": "07ca0dfe-b006-46d0-b7d7-c4e4d17b93f4", "name": "", "x": 38.7015268414049, "y": -122.37702834108411, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6f0255b7-5369-40eb-8814-959b0d4245b6", "name": "p1rdt78lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "07ca0dfe-b006-46d0-b7d7-c4e4d17b93f4"}}}}, {"uuid": "aa172697-4d3c-4c21-ad14-791eaaaae1de", "name": "", "x": 38.701501251821085, "y": -122.3767680365563, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c108a0c2-3093-4222-9547-5ac08f6d8a4a", "name": "p1rdm167", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aa172697-4d3c-4c21-ad14-791eaaaae1de"}}}}, {"uuid": "aa54beeb-e05e-40ae-b161-8212e8387d82", "name": "", "x": 38.701672466226256, "y": -122.3767665504658, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a0ae6c02-c29e-4bf9-b1d4-ecc7e37e7de2", "name": "p1rlv159", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aa54beeb-e05e-40ae-b161-8212e8387d82"}}}}, {"uuid": "fbaafc47-9f3c-4277-aaf2-71b0af1b7b7f", "name": "", "x": 38.701573552558834, "y": -122.37796740020737, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "624d03d5-ac53-4d58-ac86-62834fa13c61", "name": "p1rdt79lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fbaafc47-9f3c-4277-aaf2-71b0af1b7b7f"}}}}, {"uuid": "5d4081fd-db54-430c-9651-49ca8ccb19c8", "name": "", "x": 38.70167012893807, "y": -122.378020087898, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "61460072-bdc5-4a70-96fa-8ecfa71623f4", "name": "p1rlv164", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5d4081fd-db54-430c-9651-49ca8ccb19c8"}}}}, {"uuid": "5ddc2017-08f1-4c34-af08-946e29dacc50", "name": "", "x": 38.70151736520935, "y": -122.37810191210743, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "937989ee-4525-4394-b04f-37d77a2c910c", "name": "p1rdm168", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ddc2017-08f1-4c34-af08-946e29dacc50"}}}}, {"uuid": "6e2f44f8-35c0-4ebe-be9e-289c5eb1dec3", "name": "", "x": 38.701243377810904, "y": -122.37795080752997, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4355a473-4643-4f72-afe8-80ce773ca8e8", "name": "p1rlv157", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6e2f44f8-35c0-4ebe-be9e-289c5eb1dec3"}}}}, {"uuid": "f766d922-c367-4ee9-9fb6-96a42381bf45", "name": "", "x": 38.70217305711017, "y": -122.38794268559874, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3ce05c72-facf-447f-ba14-cc2ef64579a8", "name": "p1rdt80lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f766d922-c367-4ee9-9fb6-96a42381bf45"}}}}, {"uuid": "6a03f728-1d34-40e8-9d44-4347597d087c", "name": "", "x": 38.70228005247363, "y": -122.38772102191264, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b1cd7284-17fb-4382-a29d-dd8c5bfd7541", "name": "p1rlv158", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a03f728-1d34-40e8-9d44-4347597d087c"}}}}, {"uuid": "35d2c24a-971e-45b2-a2e3-22eccd876c81", "name": "", "x": 38.7016172629152, "y": -122.37771401826583, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1b610625-09e3-4b72-a8fe-b0c36f5e137c", "name": "p1rdt81lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "35d2c24a-971e-45b2-a2e3-22eccd876c81"}}}}, {"uuid": "f378ac7d-d200-4e41-a406-ab7054564695", "name": "", "x": 38.701704338541916, "y": -122.37767478667475, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fd2fae5a-e5dd-4ad4-8acc-422de00ae83e", "name": "p1rlv160", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f378ac7d-d200-4e41-a406-ab7054564695"}}}}, {"uuid": "85bcfea0-d3da-47ac-b484-16d7e9deb5ef", "name": "", "x": 38.7014372533443, "y": -122.37659609024615, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e2dad274-0d92-42fa-bf1e-a22af034211f", "name": "p1rdm172", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "85bcfea0-d3da-47ac-b484-16d7e9deb5ef"}}}}, {"uuid": "67b2edbf-fb9a-4042-9878-0abb256c07b4", "name": "", "x": 38.701284735816664, "y": -122.3767239154521, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4842819e-3f17-47da-a8bf-c3402c3c00b7", "name": "p1rlv161", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "67b2edbf-fb9a-4042-9878-0abb256c07b4"}}}}, {"uuid": "8faa352b-237f-48a0-9eeb-1ca7041e4a54", "name": "", "x": 38.701286056772844, "y": -122.37644037803527, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9872669f-fd85-458a-8951-ec12965fb42b", "name": "p1rdt82lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8faa352b-237f-48a0-9eeb-1ca7041e4a54"}}}}, {"uuid": "e2c58a52-518f-4c8c-9b38-b8662ad5ade7", "name": "", "x": 38.70116550444912, "y": -122.3763339478172, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "44bdfec0-2d44-442d-b562-ac786c61a76a", "name": "p1rdm173", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e2c58a52-518f-4c8c-9b38-b8662ad5ade7"}}}}, {"uuid": "c8e5702d-def0-482b-8f6a-0620e7bbbeff", "name": "", "x": 38.70118248419553, "y": -122.37613829900104, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b7538477-32ab-4db6-872d-83be7ec89fd9", "name": "p1rlv830", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c8e5702d-def0-482b-8f6a-0620e7bbbeff"}}}}, {"uuid": "3adcb55d-9b1a-46b3-b905-26ad4c6bff2d", "name": "", "x": 38.70185461418825, "y": -122.38682011107082, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8dac1e07-5eb6-4945-a3d9-95b77310358d", "name": "p1rdt83lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3adcb55d-9b1a-46b3-b905-26ad4c6bff2d"}}}}, {"uuid": "4a73fce2-8e99-4a9f-bc75-215c102dbda8", "name": "", "x": 38.702004410202626, "y": -122.38671135342908, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "471bad88-4514-4b02-aa1a-1d2aaa15557f", "name": "p1rlv163", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4a73fce2-8e99-4a9f-bc75-215c102dbda8"}}}}, {"uuid": "fbb96684-d951-42a4-a1f6-ce4c0c253377", "name": "", "x": 38.70161136737774, "y": -122.38394317395175, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d9de64e4-b140-4526-af3c-1f7ceaa687bf", "name": "p1rdm175", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fbb96684-d951-42a4-a1f6-ce4c0c253377"}}}}, {"uuid": "5a097ffc-12e8-463a-bd24-dd8185e42490", "name": "", "x": 38.701999398350054, "y": -122.38404334662313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9e7880c9-0932-4395-abf9-2274e400f280", "name": "p1rlv165", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5a097ffc-12e8-463a-bd24-dd8185e42490"}}}}, {"uuid": "61710186-ca37-4767-9c87-d70a0b168e59", "name": "", "x": 38.70158970365277, "y": -122.38378988145172, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bdb8aaf1-0e21-42e0-a72d-666646561235", "name": "p1rdt84lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "61710186-ca37-4767-9c87-d70a0b168e59"}}}}, {"uuid": "5d8a0ae0-27e3-4461-b370-f4c1e51c40dd", "name": "", "x": 38.701645776351214, "y": -122.38363237450628, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8a6bf0b9-809d-48fb-b8bd-375df052b6cc", "name": "p1rdm176", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5d8a0ae0-27e3-4461-b370-f4c1e51c40dd"}}}}, {"uuid": "209596cf-c99f-4561-a520-381ebd08802a", "name": "", "x": 38.70187142242643, "y": -122.3836994386808, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "21d333f7-7426-4fa6-8ab2-c6118055ece1", "name": "p1rlv166", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "209596cf-c99f-4561-a520-381ebd08802a"}}}}, {"uuid": "a079cab2-18b3-4986-9bd6-e862df6a3992", "name": "", "x": 38.70159534277448, "y": -122.37751697598218, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "40f4034e-c735-419b-80cd-d729d75f4692", "name": "p1rdt85lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a079cab2-18b3-4986-9bd6-e862df6a3992"}}}}, {"uuid": "d5be180e-e603-44df-91b2-15bf09529aaa", "name": "", "x": 38.70142358074945, "y": -122.3774127173029, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "470fe3ed-5b24-438a-ba6d-cdd9f774e5ad", "name": "p1rlv168", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d5be180e-e603-44df-91b2-15bf09529aaa"}}}}, {"uuid": "9ad1b5f7-6de7-45a6-82fa-a019f2a2d2dd", "name": "", "x": 38.69187926915615, "y": -122.40371977394915, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29", "name": "p1rdt89lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9ad1b5f7-6de7-45a6-82fa-a019f2a2d2dd"}}}}, {"uuid": "2dcf3d7d-5bad-4a2a-89df-cc749726edb1", "name": "", "x": 38.69174128032129, "y": -122.40438031441046, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1186295-59ff-48a8-b31d-0f7cd40df1ab", "name": "p1rlv174", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2dcf3d7d-5bad-4a2a-89df-cc749726edb1"}}}}, {"uuid": "b8b95dc9-b571-48bb-b6a5-505568391f8f", "name": "", "x": 38.69209810103375, "y": -122.40366444006949, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "905e9287-bdb6-44e0-b0af-f59ab4ad4d8e", "name": "p1rlv175", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b8b95dc9-b571-48bb-b6a5-505568391f8f"}}}}, {"uuid": "fd83f614-e9b0-4c57-8f6b-38f4f1283fb9", "name": "", "x": 38.69217885130816, "y": -122.4035947777604, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "931c8cee-89fe-447d-8788-af1e5f9f8775", "name": "p1rlv176", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fd83f614-e9b0-4c57-8f6b-38f4f1283fb9"}}}}, {"uuid": "d368bf8f-c6cb-4bf9-ac2a-89d02da7ed90", "name": "", "x": 38.6915327307124, "y": -122.40412907570833, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "090d6084-5cc6-473d-99c0-a6309571d633", "name": "p1rlv177", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d368bf8f-c6cb-4bf9-ac2a-89d02da7ed90"}}}}, {"uuid": "f010dad3-54f5-452e-a9dc-a82317b93f0f", "name": "", "x": 38.69192571259695, "y": -122.40343589909303, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a9debf70-62f4-4870-ad8b-bffc4bc4ad3f", "name": "p1rlv178", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f010dad3-54f5-452e-a9dc-a82317b93f0f"}}}}, {"uuid": "3b0576c8-db7c-411b-9c1c-bfa9f59cbb2b", "name": "", "x": 38.69194238589858, "y": -122.40317129254535, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fb03260b-d7d7-4779-ab2c-37c9a1e34d66", "name": "p1rlv179", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3b0576c8-db7c-411b-9c1c-bfa9f59cbb2b"}}}}, {"uuid": "1d052612-64a8-4667-9de7-cadc1ee125d3", "name": "", "x": 38.690562886551874, "y": -122.39178515337943, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d156fdde-5620-4a6f-b8c1-a3ab986fcc88", "name": "p1rdt150lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d052612-64a8-4667-9de7-cadc1ee125d3"}}}}, {"uuid": "30a89bc3-9ed4-40c7-9ecb-6c588b8c5880", "name": "", "x": 38.69053687920906, "y": -122.3917425303033, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8d3a86df-2ac5-4959-b857-562795ce84ba", "name": "p1rlv285", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "30a89bc3-9ed4-40c7-9ecb-6c588b8c5880"}}}}, {"uuid": "53d8affc-2792-4637-a447-6a4e58c78313", "name": "", "x": 38.66809150084286, "y": -122.48424417400362, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d64d858-a9f7-430f-890e-a456f8913c30", "name": "p1rdt177lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "53d8affc-2792-4637-a447-6a4e58c78313"}}}}, {"uuid": "7607cd8e-f257-4a6d-b55c-9a898d29baf6", "name": "", "x": 38.66811702312487, "y": -122.4842010892547, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "57b88281-b728-4779-82b1-4cc9eb4b41b1", "name": "p1rlv337", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7607cd8e-f257-4a6d-b55c-9a898d29baf6"}}}}, {"uuid": "de0c745d-5ced-43d0-9095-ed76c1548f39", "name": "", "x": 38.681876674272594, "y": -122.49390622766961, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b3314fa8-a838-4028-abb5-043425fd0785", "name": "p1rdt178lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "de0c745d-5ced-43d0-9095-ed76c1548f39"}}}}, {"uuid": "81b033cd-6820-4e9d-9d4a-fe4406f73e5e", "name": "", "x": 38.68190220002097, "y": -122.49386313799357, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e6b2aba6-a289-4a50-a131-2064047d1341", "name": "p1rlv338", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "81b033cd-6820-4e9d-9d4a-fe4406f73e5e"}}}}, {"uuid": "a7b6930a-f33e-4110-8b61-e7e73d1f1ddc", "name": "", "x": 38.66898414531813, "y": -122.45869594003535, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c3e633bc-311e-4698-a413-9c6cf09c42a8", "name": "p1rdt180lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a7b6930a-f33e-4110-8b61-e7e73d1f1ddc"}}}}, {"uuid": "6b1f1532-b5d7-4977-bb8a-eeb24a23de79", "name": "", "x": 38.66899849994981, "y": -122.45874675513116, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bb4797d6-b46e-4058-8985-d9f4b660f0a7", "name": "p1rlv340", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6b1f1532-b5d7-4977-bb8a-eeb24a23de79"}}}}, {"uuid": "ea35ba17-1f44-4509-80ca-f02601f3838a", "name": "", "x": 38.75302665769167, "y": -122.36662619401973, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "05401825-91f8-41f8-9204-ab5806458594", "name": "p1rdt181lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea35ba17-1f44-4509-80ca-f02601f3838a"}}}}, {"uuid": "53a2fe42-5fec-4c3f-bb86-47337d445449", "name": "", "x": 38.75299240671526, "y": -122.36643483348682, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "54f0ea2c-3849-4ff0-ad8c-e3f65515d178", "name": "p1rlv341", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "53a2fe42-5fec-4c3f-bb86-47337d445449"}}}}, {"uuid": "d7210e3a-8ceb-4042-887e-2baf51dd5726", "name": "", "x": 38.75309371224946, "y": -122.36683673194118, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "13754fdb-4039-49fb-b584-8437191dfb2b", "name": "p1rlv342", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d7210e3a-8ceb-4042-887e-2baf51dd5726"}}}}, {"uuid": "953e5e3a-8f85-4748-8249-0703ee775dc5", "name": "", "x": 38.67877405858776, "y": -122.47520020508532, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "db407ddd-fb81-4767-99e1-9aeab12fc770", "name": "p1rdt182lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "953e5e3a-8f85-4748-8249-0703ee775dc5"}}}}, {"uuid": "2f6bbaf5-24aa-40e8-b566-845c59a445a2", "name": "", "x": 38.6787480814273, "y": -122.47515755839895, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0197ef22-9f8f-48a9-84de-663a7ce22773", "name": "p1rlv343", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2f6bbaf5-24aa-40e8-b566-845c59a445a2"}}}}, {"uuid": "35e5b909-f634-4a8b-b66b-4e8bede0808f", "name": "", "x": 38.68506507552232, "y": -122.35588924552482, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4724ea16-dc31-48f8-98b8-b9a223e9a4bb", "name": "p1rdt209lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "35e5b909-f634-4a8b-b66b-4e8bede0808f"}}}}, {"uuid": "1ba1a288-120a-4dbf-bfb8-42f4858ad738", "name": "", "x": 38.68512263068088, "y": -122.3560076800405, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7e1ea241-5329-4db5-996a-df09a9c25687", "name": "p1rlv377", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1ba1a288-120a-4dbf-bfb8-42f4858ad738"}}}}, {"uuid": "4df59d4a-6893-4f1b-b48e-0db3cf09f7af", "name": "", "x": 38.68504927407323, "y": -122.35577838786406, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "50225dcf-40bc-44b5-9dec-072ac5b2334e", "name": "p1rlv379", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4df59d4a-6893-4f1b-b48e-0db3cf09f7af"}}}}, {"uuid": "1885af1b-3bcd-4472-8d94-a5c3f52eb2c6", "name": "", "x": 38.684623418522186, "y": -122.35792952524736, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "05f6a3bf-d465-4f16-8205-616d1f4dd465", "name": "p1rdt210lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1885af1b-3bcd-4472-8d94-a5c3f52eb2c6"}}}}, {"uuid": "61baa391-c9f5-4078-ac02-6dd3b54a83b1", "name": "", "x": 38.684597398947716, "y": -122.35788691809313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d3ff63a0-bf3f-43b0-807c-935467b4fe46", "name": "p1rlv378", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "61baa391-c9f5-4078-ac02-6dd3b54a83b1"}}}}, {"uuid": "10baed55-38a3-44cd-93db-649b00e85837", "name": "", "x": 38.68355474726837, "y": -122.35674337268465, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1d5af6ce-9a4c-414a-bbd8-15d82f50cb57", "name": "p1rdt211lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10baed55-38a3-44cd-93db-649b00e85837"}}}}, {"uuid": "08ef91ea-1f5d-4f98-98c3-eb8f6fa34493", "name": "", "x": 38.68358022206023, "y": -122.35670023394748, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0ee07ef9-b7b0-4457-be1c-78e754dbcfc7", "name": "p1rlv380", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "08ef91ea-1f5d-4f98-98c3-eb8f6fa34493"}}}}, {"uuid": "16164883-d887-47fc-aabd-993c8668dba9", "name": "", "x": 38.70346378054364, "y": -122.37754850885149, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "591461d4-20da-4165-a210-4dbaedd81016", "name": "p1rdt233lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "16164883-d887-47fc-aabd-993c8668dba9"}}}}, {"uuid": "646ac96d-cdc9-49c3-a0f1-3ae8e77da6b9", "name": "", "x": 38.703632263710084, "y": -122.37756607257536, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b54aae8-5a94-4e04-882f-748e1c5f1390", "name": "p1rlv415", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "646ac96d-cdc9-49c3-a0f1-3ae8e77da6b9"}}}}, {"uuid": "6c429ce0-0fef-418f-9d71-d67238478aa4", "name": "", "x": 38.70329902987842, "y": -122.37760346268222, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "99abc7dc-8e15-420f-9bc9-0e6229d4dab3", "name": "p1rlv416", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c429ce0-0fef-418f-9d71-d67238478aa4"}}}}, {"uuid": "9497beca-f842-4ee6-a8e5-508ab4b0b459", "name": "", "x": 38.70344498505631, "y": -122.37793571026356, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "019c88af-413c-4331-84f7-923a1df0a303", "name": "p1rdm434", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9497beca-f842-4ee6-a8e5-508ab4b0b459"}}}}, {"uuid": "0262bf06-9770-4733-99e9-cf98f80a689b", "name": "", "x": 38.703688840272775, "y": -122.37803710181561, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6b33ed36-116b-4741-9374-6927bd537427", "name": "p1rlv412", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0262bf06-9770-4733-99e9-cf98f80a689b"}}}}, {"uuid": "32ce07e1-cf47-4abf-b3bf-24f51f6cfdb1", "name": "", "x": 38.703449772341166, "y": -122.3771421382582, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e3b3eb51-c011-4f2c-8a10-c43c9c86217b", "name": "p1rdm437", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "32ce07e1-cf47-4abf-b3bf-24f51f6cfdb1"}}}}, {"uuid": "294366aa-f7eb-4e04-8d91-2eceb5798884", "name": "", "x": 38.70363888674939, "y": -122.37711749672587, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e7935b9c-b631-432c-a322-9beea73f1fc4", "name": "p1rlv419", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "294366aa-f7eb-4e04-8d91-2eceb5798884"}}}}, {"uuid": "6bcfb4f6-2e39-4863-80fb-e741b4350228", "name": "", "x": 38.70342206460632, "y": -122.37701587380883, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1a713d96-e13f-447e-ab9f-012af3e26afe", "name": "p1rdm438", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6bcfb4f6-2e39-4863-80fb-e741b4350228"}}}}, {"uuid": "d9702311-ea42-4ddf-ae4e-121430adc593", "name": "", "x": 38.703538904912854, "y": -122.37695735772205, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be4d7ed8-5ddd-4127-87ab-eb3f48a580c2", "name": "p1rlv420", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d9702311-ea42-4ddf-ae4e-121430adc593"}}}}, {"uuid": "ad647b8c-5c1a-41de-9194-421c09929204", "name": "", "x": 38.70315939892254, "y": -122.38015776111975, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "adb2d039-e162-43f7-8498-1374581a75fc", "name": "p1rdm439", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ad647b8c-5c1a-41de-9194-421c09929204"}}}}, {"uuid": "760681c9-084f-4e36-a61d-5f3745e7cd14", "name": "", "x": 38.70329481206863, "y": -122.38020259377379, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8408ac87-a086-46bc-9d88-cca79e17dd62", "name": "p1rlv413", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "760681c9-084f-4e36-a61d-5f3745e7cd14"}}}}, {"uuid": "d0c778bc-b90c-47b5-8172-39b840e24616", "name": "", "x": 38.70311258602368, "y": -122.38036119573296, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e480f304-b192-4107-91e1-131d481657b2", "name": "p1rdt234lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d0c778bc-b90c-47b5-8172-39b840e24616"}}}}, {"uuid": "dcdc577e-1e4f-42be-b252-c5958b06d753", "name": "", "x": 38.7029185925103, "y": -122.38063135468911, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "84570b2e-efeb-477e-be1c-43b9d2922fda", "name": "p1rdm440", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dcdc577e-1e4f-42be-b252-c5958b06d753"}}}}, {"uuid": "3fe19806-a4a8-4e42-a1c2-255007fc068e", "name": "", "x": 38.7029199228882, "y": -122.38034781076358, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "49dbdd44-a36a-46b5-aef8-558ef7693315", "name": "p1rlv417", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3fe19806-a4a8-4e42-a1c2-255007fc068e"}}}}, {"uuid": "f7a94d2a-3acd-4984-af0d-c281cf5c686d", "name": "", "x": 38.702857286057856, "y": -122.38150193355499, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d8a6708a-d098-4e02-aac6-4aba7fdc71a5", "name": "p1rdt235lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f7a94d2a-3acd-4984-af0d-c281cf5c686d"}}}}, {"uuid": "25aebc37-4fc6-4413-8a7a-b0c4254ee4f0", "name": "", "x": 38.70300468515236, "y": -122.38157364260027, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "12dcb168-1bfe-448b-8d9a-f5cb4c61aafe", "name": "p1rlv421", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "25aebc37-4fc6-4413-8a7a-b0c4254ee4f0"}}}}, {"uuid": "deb1598d-1ec1-41d1-8f30-df41804e8290", "name": "", "x": 38.70336335384591, "y": -122.37836945726418, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7dd709e3-c5ec-4a01-8297-11f4d1261c3a", "name": "p1rdt236lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "deb1598d-1ec1-41d1-8f30-df41804e8290"}}}}, {"uuid": "4713b3a2-a889-4ee0-b304-c3718091deae", "name": "", "x": 38.70357389491814, "y": -122.3784521142025, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aa7bb51b-8ba8-4a05-872a-7f5ce084fe88", "name": "p1rlv422", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4713b3a2-a889-4ee0-b304-c3718091deae"}}}}, {"uuid": "299ac3a7-1294-41c6-bdfe-f81fcbac0440", "name": "", "x": 38.70326683877779, "y": -122.37832826777388, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6c1e9680-f7de-497c-953a-54f4db2899e2", "name": "p1rlv423", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "299ac3a7-1294-41c6-bdfe-f81fcbac0440"}}}}, {"uuid": "69492088-1302-4501-8eb1-50d1ab439d19", "name": "", "x": 38.69944370500361, "y": -122.41580872476209, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b72726f3-250c-4d98-86bc-5120137bd0f1", "name": "p1rdt237lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "69492088-1302-4501-8eb1-50d1ab439d19"}}}}, {"uuid": "98d78dd8-503b-4dca-8dd9-5465a16c50ee", "name": "", "x": 38.69954841432615, "y": -122.41568889821919, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e1a91c8c-aabd-4fad-8306-908f186a5744", "name": "p1rlv424", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "98d78dd8-503b-4dca-8dd9-5465a16c50ee"}}}}, {"uuid": "85c0e239-6490-4ec7-87dd-d66b31f76a42", "name": "", "x": 38.69927637037365, "y": -122.4159171313363, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "753035df-8705-48eb-92b3-c4bef603b66b", "name": "p1rlv449", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "85c0e239-6490-4ec7-87dd-d66b31f76a42"}}}}, {"uuid": "9558861f-5a1b-4bd9-ba31-559c8aa3081b", "name": "", "x": 38.70680842002751, "y": -122.42486556791981, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "42dff28c-89e7-4b56-bf23-3dcdd3ca216f", "name": "p1rdt251lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9558861f-5a1b-4bd9-ba31-559c8aa3081b"}}}}, {"uuid": "e1935b1d-1c47-4379-ae94-01784a6da9a1", "name": "", "x": 38.70631853264042, "y": -122.42524857112629, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2f771660-4dad-43df-b38b-7da5f6180a25", "name": "p1rlv439", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e1935b1d-1c47-4379-ae94-01784a6da9a1"}}}}, {"uuid": "dee0ea3a-c26d-4a97-b33b-933c3b68df0b", "name": "", "x": 38.70720720644569, "y": -122.42453989136035, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0d665758-71e1-4478-b39d-671f78f623e5", "name": "p1rlv445", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dee0ea3a-c26d-4a97-b33b-933c3b68df0b"}}}}, {"uuid": "ce5d7daa-a960-4160-80bd-5a74b7ce65ff", "name": "", "x": 38.70744608256419, "y": -122.42546956600445, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "acce3105-f519-491c-921a-df1294795742", "name": "p1rlv446", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ce5d7daa-a960-4160-80bd-5a74b7ce65ff"}}}}, {"uuid": "29f44b7f-784a-4c81-83d9-75ac5e82c9e1", "name": "", "x": 38.70608276722945, "y": -122.42495143556884, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "042873fa-10df-4de0-a040-ac429b8bf7d9", "name": "p1rlv447", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "29f44b7f-784a-4c81-83d9-75ac5e82c9e1"}}}}, {"uuid": "5305ea3c-176d-4627-80b2-70f68e3b3249", "name": "", "x": 38.70711624377896, "y": -122.42436810473787, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4bb83d65-630d-4f1d-8e3d-8937a5a05524", "name": "p1rlv448", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5305ea3c-176d-4627-80b2-70f68e3b3249"}}}}, {"uuid": "8c2a657b-ca27-44ca-9109-2bc7768188c8", "name": "", "x": 38.78777229039905, "y": -122.347029423475, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "704fece3-3b83-4c0b-bcd1-d463b3cdaf6b", "name": "p1rdt253lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8c2a657b-ca27-44ca-9109-2bc7768188c8"}}}}, {"uuid": "793f6ac1-bd76-48ee-b6b1-d7f4fea5c5fb", "name": "", "x": 38.78740834836766, "y": -122.34691362308135, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0a778b00-482c-4b81-8213-f17202a105fa", "name": "p1rlv441", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "793f6ac1-bd76-48ee-b6b1-d7f4fea5c5fb"}}}}, {"uuid": "c229e0d5-b101-4f6e-b560-2f2e9acc9bab", "name": "", "x": 38.78809447859801, "y": -122.3471376433436, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "30f29674-3083-4da2-95e2-a1f11a7eb7f8", "name": "p1rlv444", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c229e0d5-b101-4f6e-b560-2f2e9acc9bab"}}}}, {"uuid": "41ca8386-0452-4bf9-be70-2fadb63707ca", "name": "", "x": 38.706805740104386, "y": -122.42594225497479, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "655d8f44-aa2f-4548-a1ca-83fcce9fa7aa", "name": "p1rdt254lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "41ca8386-0452-4bf9-be70-2fadb63707ca"}}}}, {"uuid": "3c269399-d74c-4d59-a8d2-dafb03efc520", "name": "", "x": 38.70689780217361, "y": -122.42576147929557, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6cd667a9-c0ef-49ce-b6ee-7e474d9ae761", "name": "p1rlv442", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3c269399-d74c-4d59-a8d2-dafb03efc520"}}}}, {"uuid": "e57dd29b-9cd7-424b-a501-9ee3096a6870", "name": "", "x": 38.706755483647314, "y": -122.4261421504902, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c2100c17-c0e6-47e9-87f8-72016b22dd4b", "name": "p1rlv443", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e57dd29b-9cd7-424b-a501-9ee3096a6870"}}}}, {"uuid": "538a31a7-d921-47e6-9d70-ef1da95cfcb4", "name": "", "x": 38.68872418378523, "y": -122.3484131511325, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e4c28500-44f7-47c6-b8a8-d1e3468494e3", "name": "p1rdt257lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "538a31a7-d921-47e6-9d70-ef1da95cfcb4"}}}}, {"uuid": "7d61257b-f6a2-48da-9a96-61fb9f4ca7c8", "name": "", "x": 38.68876626401415, "y": -122.34840879300008, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bb46f1ae-0cdb-45d1-b389-639cdf345f8e", "name": "p1rlv452", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7d61257b-f6a2-48da-9a96-61fb9f4ca7c8"}}}}, {"uuid": "80be5501-4a72-4a0b-a037-72d42ecb1ebd", "name": "", "x": 38.69599975733859, "y": -122.39252773638533, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ad9ffaef-f21b-43da-9f67-3a8271edb6bd", "name": "p1rdt258lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "80be5501-4a72-4a0b-a037-72d42ecb1ebd"}}}}, {"uuid": "98e49797-c26c-470d-af4f-29283772b7f7", "name": "", "x": 38.695944209864116, "y": -122.39278871278485, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f6a8a3c7-5165-48b7-8233-30d3af045442", "name": "p1rlv453", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "98e49797-c26c-470d-af4f-29283772b7f7"}}}}, {"uuid": "f90c9866-5b26-4071-a4fc-b0a7d6c52f2d", "name": "", "x": 38.69600232943997, "y": -122.39183378308958, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "85f0d94e-c096-4d53-ae05-f0dc59f73d02", "name": "p1rlv456", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f90c9866-5b26-4071-a4fc-b0a7d6c52f2d"}}}}, {"uuid": "de4f8fed-9482-452a-90c9-5e7caec23923", "name": "", "x": 38.69599911358809, "y": -122.39294923817128, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "76b212f9-2e27-4064-a2c5-079786afb1d1", "name": "p1rlv460", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "de4f8fed-9482-452a-90c9-5e7caec23923"}}}}, {"uuid": "54918463-a6a7-4a05-bf52-c9011253cbfc", "name": "", "x": 38.68471814126827, "y": -122.36995372008337, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c6a0feb3-78c1-4d69-8d18-2a8c3abdcf54", "name": "p1rdt259lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "54918463-a6a7-4a05-bf52-c9011253cbfc"}}}}, {"uuid": "661f61fe-a47e-42bd-9f59-20f5526dc5b4", "name": "", "x": 38.684738584166, "y": -122.36987703423111, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3493b0ed-43a2-4602-a7ad-a817331c9d8e", "name": "p1rlv454", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "661f61fe-a47e-42bd-9f59-20f5526dc5b4"}}}}, {"uuid": "9a532ae9-3d3d-4204-b6db-339efb98c7a9", "name": "", "x": 38.68473945129645, "y": -122.37003799082656, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "552153cc-f5be-42ee-9985-9361c2e7e2a1", "name": "p1rlv455", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9a532ae9-3d3d-4204-b6db-339efb98c7a9"}}}}, {"uuid": "02d1b4b0-73de-4ac2-9167-0f91c0a87843", "name": "", "x": 38.69417505217448, "y": -122.39691277672273, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d8d796d8-6750-4ca5-ae07-1b07331ce6ee", "name": "p1rdt260lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "02d1b4b0-73de-4ac2-9167-0f91c0a87843"}}}}, {"uuid": "c2a504be-9d17-43d9-a528-ac7860584549", "name": "", "x": 38.69444988952913, "y": -122.39658452058625, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ec66e302-748d-4300-ba65-719de0a906bb", "name": "p1rlv458", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c2a504be-9d17-43d9-a528-ac7860584549"}}}}, {"uuid": "3faab6eb-e94a-4a73-8298-c56a3209c291", "name": "", "x": 38.69489061384813, "y": -122.39641983065454, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "76dd0f1b-4109-4707-a547-f0ab1b6e148f", "name": "p1rlv461", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3faab6eb-e94a-4a73-8298-c56a3209c291"}}}}, {"uuid": "e28b20ea-136d-493a-b93f-1d8c8d2e0275", "name": "", "x": 38.69609340912066, "y": -122.39266578758262, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fe4ec5b6-61fb-4b66-9e43-19d81af88966", "name": "p1rdt261lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e28b20ea-136d-493a-b93f-1d8c8d2e0275"}}}}, {"uuid": "32b9738c-437a-49e1-bcf9-ba63fbef1757", "name": "", "x": 38.69613569697208, "y": -122.39266409008623, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4c112196-bcbc-41bc-99a9-f3657c335c7a", "name": "p1rlv459", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "32b9738c-437a-49e1-bcf9-ba63fbef1757"}}}}, {"uuid": "fc0b9de9-847e-4f4c-9650-639faab16240", "name": "", "x": 38.69746455104433, "y": -122.39109295618859, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "30952601-1479-4770-9b77-9fe3465310b7", "name": "p1rdt262lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fc0b9de9-847e-4f4c-9650-639faab16240"}}}}, {"uuid": "4bce323d-cade-48f6-bd80-19de38309d9c", "name": "", "x": 38.697566588571334, "y": -122.39110756675504, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9176da24-7eb5-4b0b-99dd-886c3f974798", "name": "p1rlv462", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4bce323d-cade-48f6-bd80-19de38309d9c"}}}}, {"uuid": "614237e9-0299-4752-b3bd-ac572efbc93f", "name": "", "x": 38.69741333633857, "y": -122.39109736665547, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "895d0235-3ee6-4f06-9978-9d615d721ebd", "name": "p1rlv464", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "614237e9-0299-4752-b3bd-ac572efbc93f"}}}}, {"uuid": "85ef6f5a-7f9c-417e-a030-2cddbc51d968", "name": "", "x": 38.69796207835795, "y": -122.39189498505252, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2c7501f4-0394-4766-a3c5-b17fda7f3817", "name": "p1rdt263lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "85ef6f5a-7f9c-417e-a030-2cddbc51d968"}}}}, {"uuid": "020235d3-cf73-4472-bd30-ddd25a084052", "name": "", "x": 38.69793607105191, "y": -122.39185235758016, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ff9d9cca-1878-478d-a190-b58c9098f13e", "name": "p1rlv463", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "020235d3-cf73-4472-bd30-ddd25a084052"}}}}, {"uuid": "a47e9ee1-03b2-4ff9-935d-f8a781ece2cd", "name": "", "x": 38.7505574694735, "y": -122.41550076869619, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d33a03d6-fddc-4e47-8018-cd7d290b30b0", "name": "p1rdt270lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a47e9ee1-03b2-4ff9-935d-f8a781ece2cd"}}}}, {"uuid": "dbb5ba0e-ba1e-4371-bcd8-6e1f788e6252", "name": "", "x": 38.75057184305653, "y": -122.41555163249289, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2e589527-d388-4364-87d2-2f4af1a14509", "name": "p1rlv474", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dbb5ba0e-ba1e-4371-bcd8-6e1f788e6252"}}}}, {"uuid": "18d6fe25-b7b6-445a-ae4b-e251280306d0", "name": "", "x": 38.77190208512443, "y": -122.36444610004378, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6715c6a-6869-412a-8e59-e5c2eb03c56b", "name": "p1rdt275lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "18d6fe25-b7b6-445a-ae4b-e251280306d0"}}}}, {"uuid": "f5d52a4c-e524-4515-8bd6-5a25557f9ba1", "name": "", "x": 38.77188833047837, "y": -122.36449725722824, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cb55ec0b-b6f7-48a7-8dae-dda95fc34499", "name": "p1rlv480", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5d52a4c-e524-4515-8bd6-5a25557f9ba1"}}}}, {"uuid": "e49c6293-1f6d-43c7-9f99-3bad9fb91f2e", "name": "", "x": 38.6981164551154, "y": -122.40319272296294, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b478b4f8-8d5e-47b0-a56a-8b991dc8d944", "name": "p1rdt276lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e49c6293-1f6d-43c7-9f99-3bad9fb91f2e"}}}}, {"uuid": "c92307a0-d75e-4ba8-8c7a-0fc694691602", "name": "", "x": 38.69831357847344, "y": -122.40315284432228, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8d9e77ad-42c6-4413-96e6-debfed3c442a", "name": "p1rlv481", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c92307a0-d75e-4ba8-8c7a-0fc694691602"}}}}, {"uuid": "78102e48-a7be-4d96-894e-01561d3adb23", "name": "", "x": 38.697080868964996, "y": -122.39900074624246, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "24486e15-ff1e-45b3-aa02-703263f04844", "name": "p1rdt277lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "78102e48-a7be-4d96-894e-01561d3adb23"}}}}, {"uuid": "4daf40d1-d481-436a-ab75-fc0ab9938839", "name": "", "x": 38.696472678672315, "y": -122.39914337613104, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8d4b708f-cc15-4ee3-87e0-4d26fec02f1e", "name": "p1rlv482", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4daf40d1-d481-436a-ab75-fc0ab9938839"}}}}, {"uuid": "7a0f4694-1f59-45db-ac24-c397b84f74bf", "name": "", "x": 38.682836254431685, "y": -122.35413994526482, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a8af5824-d5d7-4cba-98b7-d72993909f22", "name": "p1rdt278lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7a0f4694-1f59-45db-ac24-c397b84f74bf"}}}}, {"uuid": "ae9edf40-7cf8-4a90-b1fb-e195a11a717e", "name": "", "x": 38.682850654364266, "y": -122.35419074861349, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d059a618-6f09-404b-b1a0-0e7aa0c55c45", "name": "p1rlv483", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ae9edf40-7cf8-4a90-b1fb-e195a11a717e"}}}}, {"uuid": "5e812994-8ece-4fc5-8b76-348599a6e2ce", "name": "", "x": 38.696321369018115, "y": -122.40303140946239, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2d6856ee-d113-45ec-99e0-8a915a89a56c", "name": "p1rdm508", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5e812994-8ece-4fc5-8b76-348599a6e2ce"}}}}, {"uuid": "b52b0521-4625-42cf-a321-7a6ef164fc92", "name": "", "x": 38.6966231134774, "y": -122.40212045173747, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fde62b60-c5f6-44d6-b2f2-211c21b02033", "name": "p1rlv484", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b52b0521-4625-42cf-a321-7a6ef164fc92"}}}}, {"uuid": "ef878753-5b7b-4b1e-adac-6f6766e7a2bf", "name": "", "x": 38.69619520198978, "y": -122.40301175619707, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4bf679fe-712f-4db6-9df9-debb29b7ee73", "name": "p1rdt279lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef878753-5b7b-4b1e-adac-6f6766e7a2bf"}}}}, {"uuid": "38f0df30-9996-4460-baaf-8cf45c0bdea2", "name": "", "x": 38.69610445115518, "y": -122.40290672048755, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9c3bf9bd-d12a-47d7-b2e2-3f31f3a0419b", "name": "p1rdm509", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "38f0df30-9996-4460-baaf-8cf45c0bdea2"}}}}, {"uuid": "6a1f742e-0281-41f8-a274-ca742d98c351", "name": "", "x": 38.69640566539714, "y": -122.40189227549035, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f8d2c379-7e19-46c4-8c6e-533fa9db7764", "name": "p1rlv485", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a1f742e-0281-41f8-a274-ca742d98c351"}}}}, {"uuid": "958a623e-a829-4d3b-b310-b6a20945b961", "name": "", "x": 38.762845986496735, "y": -122.35672935763573, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e4eafd2-0f68-4e2a-a62c-89cb877004d4", "name": "p1rdt280lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "958a623e-a829-4d3b-b310-b6a20945b961"}}}}, {"uuid": "13e2dd00-cffc-4b7a-8ed9-55c3876df7bd", "name": "", "x": 38.762552303891766, "y": -122.35627912797126, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a54b2228-9e7d-4e6b-939d-ab2765454522", "name": "p1rlv486", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "13e2dd00-cffc-4b7a-8ed9-55c3876df7bd"}}}}, {"uuid": "4ee1cc19-733f-450e-b658-7f8074b32937", "name": "", "x": 38.75426623013744, "y": -122.36483936695494, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3e01a56d-1bfc-4169-9c3e-1373f9dbeb38", "name": "p1rdt281lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ee1cc19-733f-450e-b658-7f8074b32937"}}}}, {"uuid": "63783525-ad46-428b-b194-e5e2392a991c", "name": "", "x": 38.754777075984755, "y": -122.36484236876056, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be2d5799-907e-46fd-a389-120aea352775", "name": "p1rlv487", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "63783525-ad46-428b-b194-e5e2392a991c"}}}}, {"uuid": "e050f717-a215-4406-852a-29b4e392e4c5", "name": "", "x": 38.7537136313869, "y": -122.3648287764951, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "97c38794-7c60-4ff8-b09b-7503c9604409", "name": "p1rlv523", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e050f717-a215-4406-852a-29b4e392e4c5"}}}}, {"uuid": "3f49fa54-5e18-452b-ac04-7e82caec4a6b", "name": "", "x": 38.723225529795435, "y": -122.41097744489697, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7a8430e1-656f-4fe2-a11b-00adf429d75d", "name": "p1rdt297lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3f49fa54-5e18-452b-ac04-7e82caec4a6b"}}}}, {"uuid": "800c1fd5-f75b-4ea4-8955-de1e60878b43", "name": "", "x": 38.72307124027624, "y": -122.41075789575113, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bef074be-aac4-4d82-a832-641729756802", "name": "p1rlv524", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "800c1fd5-f75b-4ea4-8955-de1e60878b43"}}}}, {"uuid": "40ccb968-5212-4fa6-8793-3d76b678e286", "name": "", "x": 38.72334331826878, "y": -122.41110077065662, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3ab8e220-faf9-4108-80f8-22d2fe326c3d", "name": "p1rlv526", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "40ccb968-5212-4fa6-8793-3d76b678e286"}}}}, {"uuid": "429e93d6-a631-4ce5-9c3c-aa5a0aa6cedf", "name": "", "x": 38.72448847815554, "y": -122.41245231274745, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33e93250-9c11-4650-9469-412129855857", "name": "p1rdt298lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "429e93d6-a631-4ce5-9c3c-aa5a0aa6cedf"}}}}, {"uuid": "0688d8cc-a312-4660-8627-495ceab33df7", "name": "", "x": 38.72453056079826, "y": -122.41244798967669, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a42f8b99-82c6-4c90-81ea-6ccb38eacfab", "name": "p1rlv525", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0688d8cc-a312-4660-8627-495ceab33df7"}}}}, {"uuid": "fab5aa33-d64c-4dcc-b8ff-14c2773f63ad", "name": "", "x": 38.670540900167985, "y": -122.47976645470963, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6353ab92-f66f-47d8-97ac-058cf030ff82", "name": "p1rdt303lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fab5aa33-d64c-4dcc-b8ff-14c2773f63ad"}}}}, {"uuid": "9eb06290-2b92-41e0-9020-16bf69db06ca", "name": "", "x": 38.67056642076858, "y": -122.47972336691173, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32a1d9d7-31c7-4def-88d4-e4d41bd21572", "name": "p1rlv531", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9eb06290-2b92-41e0-9020-16bf69db06ca"}}}}, {"uuid": "8fb02675-4391-4938-a19f-1fd47ec0ceda", "name": "", "x": 38.67227127773109, "y": -122.47626596196271, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6a22ac71-bf3a-4016-86ce-fb25f471be5b", "name": "p1rdt304lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8fb02675-4391-4938-a19f-1fd47ec0ceda"}}}}, {"uuid": "98e5c374-ce1a-433a-8af6-cdab22541808", "name": "", "x": 38.67217810662493, "y": -122.4762166840671, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1362feeb-2e2c-4dd1-9f49-239c952c6120", "name": "p1rlv532", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "98e5c374-ce1a-433a-8af6-cdab22541808"}}}}, {"uuid": "b1b16ed0-c803-4ef8-af4d-bcfbdb7bd045", "name": "", "x": 38.67233171369118, "y": -122.47630752878543, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1f79bc5f-375f-4ecd-b828-eb7b137d7cab", "name": "p1rlv533", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b1b16ed0-c803-4ef8-af4d-bcfbdb7bd045"}}}}, {"uuid": "98bbd597-db60-4a2a-8e22-d8fd7c316c09", "name": "", "x": 38.67073161586084, "y": -122.47582091564139, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "90948977-fe1a-43b3-a8a4-86c080ae4906", "name": "p1rdt305lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "98bbd597-db60-4a2a-8e22-d8fd7c316c09"}}}}, {"uuid": "7f11a1c9-7fc0-498c-a911-6ffb6fc8d6be", "name": "", "x": 38.67104039312592, "y": -122.47571918109917, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0eb7074c-0745-4089-9329-aa3495f9b460", "name": "p1rlv534", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7f11a1c9-7fc0-498c-a911-6ffb6fc8d6be"}}}}, {"uuid": "ce2d9c5a-57c3-4ef1-b7d9-f4624daa6515", "name": "", "x": 38.67049996143512, "y": -122.47578059875961, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9cc91945-564c-4ace-bb53-77150b107b41", "name": "p1rlv535", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ce2d9c5a-57c3-4ef1-b7d9-f4624daa6515"}}}}, {"uuid": "58063c7b-e265-41f6-9754-559892ab8f15", "name": "", "x": 38.6707171128322, "y": -122.47597443436533, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d2ea78a8-b9c5-4760-b153-51b45565069e", "name": "p1rlv536", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "58063c7b-e265-41f6-9754-559892ab8f15"}}}}, {"uuid": "3a81837a-b6e1-4684-9525-903af091b574", "name": "", "x": 38.671226697580636, "y": -122.49048662526606, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "53eba878-66fa-4d30-8af4-1f583abe5f16", "name": "p1rdt306lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3a81837a-b6e1-4684-9525-903af091b574"}}}}, {"uuid": "31601fbd-a6ef-4c97-97da-e3c1cee1ddcf", "name": "", "x": 38.67124103844962, "y": -122.49053744844569, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9f2dfc9e-0b72-4465-b46a-d4e2a7a08f64", "name": "p1rlv537", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "31601fbd-a6ef-4c97-97da-e3c1cee1ddcf"}}}}, {"uuid": "1447dd15-b11d-4b92-aee8-fa7c9a86ea06", "name": "", "x": 38.685116671576026, "y": -122.45208329969167, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b8e448ea-e66d-4e16-80c0-8e742d7cac55", "name": "p1rdt335lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1447dd15-b11d-4b92-aee8-fa7c9a86ea06"}}}}, {"uuid": "20dab0fc-7fd8-4fca-bbe2-8c2946d2e18d", "name": "", "x": 38.68493681955931, "y": -122.45218585265648, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75628d41-a82d-4425-8aa2-9f377c771a4c", "name": "p1rlv588", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "20dab0fc-7fd8-4fca-bbe2-8c2946d2e18d"}}}}, {"uuid": "e11e5579-8701-4498-9418-0b99d6060f71", "name": "", "x": 38.6854049831095, "y": -122.45209030229843, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7a1c60be-f1a1-48d6-b396-4cca6d8c4e62", "name": "p1rlv589", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e11e5579-8701-4498-9418-0b99d6060f71"}}}}, {"uuid": "d9e96ec4-e74e-4618-9ee7-65d34c892888", "name": "", "x": 38.685061363444774, "y": -122.45183997708463, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "81ce208e-7244-418a-9867-b55b95ba0716", "name": "p1rlv590", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d9e96ec4-e74e-4618-9ee7-65d34c892888"}}}}, {"uuid": "10862e71-ec7d-4875-839a-324f8b84aa90", "name": "", "x": 38.68749417205864, "y": -122.45093337637859, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35993388-185f-4d1d-9dcb-16eb7556728f", "name": "p1rdt374lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10862e71-ec7d-4875-839a-324f8b84aa90"}}}}, {"uuid": "5987b6b3-bd40-4102-a885-a2b6b4a0a8d3", "name": "", "x": 38.687468186113925, "y": -122.45089073343217, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6e58890e-e6ce-4dda-91c0-5ccfdb5c420d", "name": "p1rlv657", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5987b6b3-bd40-4102-a885-a2b6b4a0a8d3"}}}}, {"uuid": "4b47f1f1-e215-42c1-aa5a-82bd5ed4ed38", "name": "", "x": 38.687021635585204, "y": -122.45201778533264, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d354e81e-b007-4bbe-b1db-50d7afacd0e0", "name": "p1rdt376lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4b47f1f1-e215-42c1-aa5a-82bd5ed4ed38"}}}}, {"uuid": "540e4606-3bc9-471d-b851-891dddd4bfbf", "name": "", "x": 38.68703599315794, "y": -122.452068611773, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "15751ee2-6783-472f-ad57-ec978234fec4", "name": "p1rlv660", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "540e4606-3bc9-471d-b851-891dddd4bfbf"}}}}, {"uuid": "b09e519e-2b26-438c-b80c-dc0e164fea9c", "name": "", "x": 38.67908332659903, "y": -122.51991969614502, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8569c197-174f-46ef-96c2-e0c674d7b046", "name": "p1rdt383lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b09e519e-2b26-438c-b80c-dc0e164fea9c"}}}}, {"uuid": "35e022ae-36d9-4824-88d4-cf5c8316580d", "name": "", "x": 38.67905736564, "y": -122.51987703293702, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eb25bf05-ce7f-405a-8c17-fd166748f7d3", "name": "p1rlv672", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "35e022ae-36d9-4824-88d4-cf5c8316580d"}}}}, {"uuid": "72ad716e-f1d2-48f5-a747-b3d15a844fd9", "name": "", "x": 38.679023967859024, "y": -122.52913908431695, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c56b4839-f007-4c9b-93a7-9147399f983f", "name": "p1rdt384lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "72ad716e-f1d2-48f5-a747-b3d15a844fd9"}}}}, {"uuid": "4cc9de64-df79-4551-84a0-ef1dbd2fec0c", "name": "", "x": 38.67837935182842, "y": -122.52878337051408, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "31d3267c-7020-4660-9a0b-49cd9d94a5d0", "name": "p1rlv673", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4cc9de64-df79-4551-84a0-ef1dbd2fec0c"}}}}, {"uuid": "17902503-2dce-426d-8ec3-66c36f03f7c9", "name": "", "x": 38.71691820009889, "y": -122.41937517163929, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "579c3e97-d1dc-4306-91e6-4cbbed29f882", "name": "p1rdt385lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "17902503-2dce-426d-8ec3-66c36f03f7c9"}}}}, {"uuid": "0575f243-1568-49fc-92d7-26cd6182fbca", "name": "", "x": 38.716892202729326, "y": -122.41933252291317, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "449992d6-a91b-40ea-9792-5166a5f2c849", "name": "p1rlv674", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0575f243-1568-49fc-92d7-26cd6182fbca"}}}}, {"uuid": "3a464616-ff46-4e66-bc71-73f7cb619077", "name": "", "x": 38.6691571170927, "y": -122.47438402684668, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "29a78735-964b-4381-bea0-01e5b1b79be9", "name": "p1rdt414lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3a464616-ff46-4e66-bc71-73f7cb619077"}}}}, {"uuid": "59455f0e-ff8f-4b31-b73e-898b6fbaf586", "name": "", "x": 38.669005790542414, "y": -122.47417070346637, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "93069f0f-fce7-47cd-b7b3-77e861f59573", "name": "p1rlv716", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59455f0e-ff8f-4b31-b73e-898b6fbaf586"}}}}, {"uuid": "4d4d97a1-ea59-48d6-b28a-5ea47726fe0d", "name": "", "x": 38.66935018999187, "y": -122.47460499537559, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1fdcbc55-681f-4fe5-8142-4945b25f6fef", "name": "p1rlv726", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d4d97a1-ea59-48d6-b28a-5ea47726fe0d"}}}}, {"uuid": "7488598b-5c4a-42eb-9cbf-5b2ea2c5d1db", "name": "", "x": 38.67353500851874, "y": -122.4699836494228, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "789d55de-619d-43cd-b056-ebe1be4c2dea", "name": "p1rdt415lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7488598b-5c4a-42eb-9cbf-5b2ea2c5d1db"}}}}, {"uuid": "8f512abc-7a0e-4beb-995e-afdea04ecb04", "name": "", "x": 38.67341206301482, "y": -122.47006900065233, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dd8fd159-f747-4ee4-a426-787f4eef4b42", "name": "p1rlv717", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8f512abc-7a0e-4beb-995e-afdea04ecb04"}}}}, {"uuid": "a5d9e4a8-f3b6-4cdb-9db1-c58f8b044a15", "name": "", "x": 38.673699700951325, "y": -122.46990593984998, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c3658479-7369-4bd9-be54-e7768c93a808", "name": "p1rlv724", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a5d9e4a8-f3b6-4cdb-9db1-c58f8b044a15"}}}}, {"uuid": "e0b96858-aa03-46db-b180-5ee0b94c7331", "name": "", "x": 38.67143528847217, "y": -122.47049470940273, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "473f5822-3412-4f3d-836e-f62314efa5b2", "name": "p1rdt416lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e0b96858-aa03-46db-b180-5ee0b94c7331"}}}}, {"uuid": "0afc18f9-d7cd-4f29-9b20-fee7da27741d", "name": "", "x": 38.67144963800081, "y": -122.4705455286412, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c4a1453b-98a3-4c2d-8ac2-c8b2ab1bfa4f", "name": "p1rlv718", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0afc18f9-d7cd-4f29-9b20-fee7da27741d"}}}}, {"uuid": "f4989904-872f-47d3-8701-93590820f835", "name": "", "x": 38.67352761620833, "y": -122.47084715807108, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "98bb09be-6506-49e8-8fd8-1a01d6861162", "name": "p1rdt417lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f4989904-872f-47d3-8701-93590820f835"}}}}, {"uuid": "e5c56170-5e6a-4e5e-93de-83a3668da549", "name": "", "x": 38.673541965589685, "y": -122.47089797885619, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d3153167-8b4c-40e4-abb7-3bdef86950c3", "name": "p1rlv719", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e5c56170-5e6a-4e5e-93de-83a3668da549"}}}}, {"uuid": "533f6e2a-609f-4f35-b833-e72a97fa7768", "name": "", "x": 38.669563658980074, "y": -122.47284200415966, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e189aaf-7650-49b4-83dd-94a29111aca2", "name": "p1rdt418lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "533f6e2a-609f-4f35-b833-e72a97fa7768"}}}}, {"uuid": "01cf012e-58c9-48bf-be58-f1427fe77a7e", "name": "", "x": 38.66958917702078, "y": -122.4727989145224, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cdbc11b7-5abf-4ff8-8d26-53faf4b1f3f5", "name": "p1rlv720", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "01cf012e-58c9-48bf-be58-f1427fe77a7e"}}}}, {"uuid": "203182a1-7f0b-4a5e-9a20-44d4dd2260c2", "name": "", "x": 38.67286897139167, "y": -122.46744763392057, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0d9603d6-5e5e-4cc0-aa86-1bdb80f7e1cf", "name": "p1rdt419lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "203182a1-7f0b-4a5e-9a20-44d4dd2260c2"}}}}, {"uuid": "43884182-507e-4cb3-964f-cbc372ccc34f", "name": "", "x": 38.67213944190893, "y": -122.46765283859665, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf12b67c-4df5-4dcb-a2e2-6ae2d0f82e65", "name": "p1rlv721", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "43884182-507e-4cb3-964f-cbc372ccc34f"}}}}, {"uuid": "398a58c5-8907-45e0-9604-09c0300e703e", "name": "", "x": 38.673435838033924, "y": -122.46736734084595, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7551be44-a4ca-4edb-b823-6495d163201e", "name": "p1rlv723", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "398a58c5-8907-45e0-9604-09c0300e703e"}}}}, {"uuid": "8c4e5f78-75c4-4283-98d4-ee2a1e884b43", "name": "", "x": 38.673174243579794, "y": -122.46731180115961, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b2bcbabc-a7fc-4230-8ec1-b6050af9cf58", "name": "p1rlv725", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8c4e5f78-75c4-4283-98d4-ee2a1e884b43"}}}}, {"uuid": "772b3248-d2cb-4f0b-ae16-539c1bc90128", "name": "", "x": 38.67078274236132, "y": -122.4676946740554, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "51673983-9230-421b-8501-bf71601b1b13", "name": "p1rdt420lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "772b3248-d2cb-4f0b-ae16-539c1bc90128"}}}}, {"uuid": "573c2087-0c8d-47da-9307-3efabbf971d7", "name": "", "x": 38.670756762481666, "y": -122.4676520348216, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4b7c6c65-e18c-4e79-b419-8894deb0d345", "name": "p1rlv722", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "573c2087-0c8d-47da-9307-3efabbf971d7"}}}}, {"uuid": "af8bd291-62f7-4b54-ba88-d62e96f0c893", "name": "", "x": 38.70121723278343, "y": -122.42203089954941, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "41f19802-32ca-4afc-8418-fe93e3ced1bb", "name": "p1rdt438lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "af8bd291-62f7-4b54-ba88-d62e96f0c893"}}}}, {"uuid": "b19a4f8f-5cf0-47ea-9609-4688e1df6de3", "name": "", "x": 38.70105000563393, "y": -122.4222662235864, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "80983704-a98f-46dc-a09f-700bd7df1a29", "name": "p1rlv749", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b19a4f8f-5cf0-47ea-9609-4688e1df6de3"}}}}, {"uuid": "4f2f25dd-3d70-420e-968d-3be4cdda8b52", "name": "", "x": 38.70143522055596, "y": -122.42180311856214, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b3c3b0fb-5a5d-439e-a350-b97ba0df41a0", "name": "p1rlv756", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4f2f25dd-3d70-420e-968d-3be4cdda8b52"}}}}, {"uuid": "4c670b17-732d-4dd3-98fc-a09595996303", "name": "", "x": 38.70124602203702, "y": -122.42077844448052, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bc7e7e51-f849-4bf4-b720-462daeb21932", "name": "p1rdt445lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c670b17-732d-4dd3-98fc-a09595996303"}}}}, {"uuid": "4ccd8de8-d3e4-446c-baf4-2b5f353790d1", "name": "", "x": 38.7012715204705, "y": -122.42073531744347, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e368704b-6c4b-4afb-a577-4b0d7a96dd65", "name": "p1rlv764", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ccd8de8-d3e4-446c-baf4-2b5f353790d1"}}}}, {"uuid": "1cc0b3d4-8021-4b32-8abb-e969a4fb62aa", "name": "", "x": 38.7015601074417, "y": -122.42258142494296, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0727e1f5-f2ca-4e19-9dc3-89e185002e52", "name": "p1rdt446lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1cc0b3d4-8021-4b32-8abb-e969a4fb62aa"}}}}, {"uuid": "c900b3f3-baf8-427c-8542-c5f2ffa1355a", "name": "", "x": 38.70157447780686, "y": -122.4226322555927, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "07381934-8e9b-4447-a330-e8af484331f1", "name": "p1rlv766", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c900b3f3-baf8-427c-8542-c5f2ffa1355a"}}}}, {"uuid": "4a885b64-5e1b-46ae-883a-62e3888a8c6a", "name": "", "x": 38.69708395346926, "y": -122.37425747756579, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "44f86829-17fc-4e83-b2a5-705454293161", "name": "p1rdt452lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4a885b64-5e1b-46ae-883a-62e3888a8c6a"}}}}, {"uuid": "918a6e1b-0380-4647-a2bd-aafaaf6b3a88", "name": "", "x": 38.69705554229972, "y": -122.37452973492258, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "180adab2-e49b-42e9-9aeb-42be0a7686c5", "name": "p1rlv786", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "918a6e1b-0380-4647-a2bd-aafaaf6b3a88"}}}}, {"uuid": "8dad0c31-e9b0-4799-b268-7c2874861bb7", "name": "", "x": 38.69721614595881, "y": -122.37422935064228, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b4fed6c4-6907-4601-9671-6f83d582dc45", "name": "p1rdm812", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8dad0c31-e9b0-4799-b268-7c2874861bb7"}}}}, {"uuid": "d3fc1810-0682-44c8-b0c8-c28ddb55de10", "name": "", "x": 38.69725422113334, "y": -122.3746085006707, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d00977fb-8d2a-44ca-aa9e-034894d6e280", "name": "p1rlv775", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d3fc1810-0682-44c8-b0c8-c28ddb55de10"}}}}, {"uuid": "75499f39-83de-43a8-a654-d945fb405baf", "name": "", "x": 38.6969100698522, "y": -122.37428951464027, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "090024f2-1724-4789-96da-174d1f5e65ec", "name": "p1rdm814", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "75499f39-83de-43a8-a654-d945fb405baf"}}}}, {"uuid": "a51d797c-e6f0-4b32-b7b9-c278c8b44c8c", "name": "", "x": 38.69694740684703, "y": -122.37453067672068, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4c5b1f75-47c0-45c3-9ef3-f97a445b242e", "name": "p1rlv776", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a51d797c-e6f0-4b32-b7b9-c278c8b44c8c"}}}}, {"uuid": "fa3c1915-fa2a-4d21-a0f6-6488b0414d01", "name": "", "x": 38.69672717493211, "y": -122.37432163006257, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d58e1471-844f-46ef-9d9a-43753b1dee25", "name": "p1rdt453lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa3c1915-fa2a-4d21-a0f6-6488b0414d01"}}}}, {"uuid": "fea9bebc-eef7-4fe5-b640-a25baff0a50c", "name": "", "x": 38.696649943652076, "y": -122.37428890620298, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ecd0e9ae-cbf4-4435-8a57-ad23e3e037b4", "name": "p1rdm815", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fea9bebc-eef7-4fe5-b640-a25baff0a50c"}}}}, {"uuid": "566e28aa-36fb-42ab-a68d-202b695174ed", "name": "", "x": 38.69663225777152, "y": -122.37457941885675, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "def7e507-cb62-42f5-8451-b8a742ef4eb2", "name": "p1rlv819", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "566e28aa-36fb-42ab-a68d-202b695174ed"}}}}, {"uuid": "7d2179fa-de53-465f-87d5-363053bbc7d5", "name": "", "x": 38.70111870876331, "y": -122.37432184237016, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d2e41779-98fa-453d-b4df-10a5dd61a4b5", "name": "p1rdm816", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7d2179fa-de53-465f-87d5-363053bbc7d5"}}}}, {"uuid": "3eef0e56-9c2d-4b51-ba64-e4b46a209297", "name": "", "x": 38.70112000065753, "y": -122.37456333253593, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6fb1fca8-7985-4356-a8de-7433fef7a454", "name": "p1rlv777", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3eef0e56-9c2d-4b51-ba64-e4b46a209297"}}}}, {"uuid": "253db7aa-5fce-4b55-9ec6-020f592f3b00", "name": "", "x": 38.70157181887224, "y": -122.3742643698461, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0b3e7941-9bdd-48f9-a4a5-a553da9bbb57", "name": "p1rdt454lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "253db7aa-5fce-4b55-9ec6-020f592f3b00"}}}}, {"uuid": "2d928d67-5f6a-413b-ae62-6f67424a1c6d", "name": "", "x": 38.70172394100054, "y": -122.37459257247573, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "87e4ddc3-ccc3-48af-bc35-d7d85f324ee7", "name": "p1rdm817", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2d928d67-5f6a-413b-ae62-6f67424a1c6d"}}}}, {"uuid": "b22926f4-6b7d-47e3-ae23-fadd82a8b5ac", "name": "", "x": 38.701795539168316, "y": -122.37449994744384, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e9ce2439-fcc7-4965-81ee-f875db83b003", "name": "p1rlv789", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b22926f4-6b7d-47e3-ae23-fadd82a8b5ac"}}}}, {"uuid": "66477536-d6bd-43e1-8c9e-745b5321f80e", "name": "", "x": 38.7013420827754, "y": -122.37396339276478, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bf188897-9db5-4ff4-8c5b-5932a8a794cf", "name": "p1rdm818", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "66477536-d6bd-43e1-8c9e-745b5321f80e"}}}}, {"uuid": "23378020-dbad-4f0d-b057-ffe4e0117567", "name": "", "x": 38.70145818262173, "y": -122.37376687845641, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3126c61-9602-45cf-8d57-27d26c14ca7e", "name": "p1rlv800", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "23378020-dbad-4f0d-b057-ffe4e0117567"}}}}, {"uuid": "846a1025-c69e-451f-9377-15537603c6e1", "name": "", "x": 38.70201519147799, "y": -122.37513054558815, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b757a90a-ade8-486f-90f1-e7c5e13708ba", "name": "p1rdm819", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "846a1025-c69e-451f-9377-15537603c6e1"}}}}, {"uuid": "fc9c2527-9baf-4404-96ae-ee464d18a789", "name": "", "x": 38.70182669191501, "y": -122.37527018819917, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "80d58665-ee8a-4f4e-a906-dc15aa3d8c6f", "name": "p1rlv778", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fc9c2527-9baf-4404-96ae-ee464d18a789"}}}}, {"uuid": "ce8a26f6-92ff-436e-bfa0-57e400e499d7", "name": "", "x": 38.7019178147915, "y": -122.37492836596363, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "53b40b3c-db5a-4fa0-bedb-f293c6eac473", "name": "p1rdt455lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ce8a26f6-92ff-436e-bfa0-57e400e499d7"}}}}, {"uuid": "87337660-1d35-46ef-9aa5-4733c6572e85", "name": "", "x": 38.70180590348404, "y": -122.37475286106623, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ea28f170-6bf0-47f7-a089-8375dff2ad4a", "name": "p1rdm820", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "87337660-1d35-46ef-9aa5-4733c6572e85"}}}}, {"uuid": "43ef4919-06d3-41a8-a235-9fbe88ea5687", "name": "", "x": 38.701671533532036, "y": -122.37490353316474, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d0089ee3-0cb4-434c-adc4-c91a8441ef0a", "name": "p1rlv787", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "43ef4919-06d3-41a8-a235-9fbe88ea5687"}}}}, {"uuid": "29077723-8ec8-453b-8c57-cdfce7b38831", "name": "", "x": 38.70149204551021, "y": -122.37504309725601, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "052949b1-9e85-4be7-993c-9e97efda3657", "name": "p1rlv811", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "29077723-8ec8-453b-8c57-cdfce7b38831"}}}}, {"uuid": "2c30f199-abfe-4d48-b1ca-b49cf7589e41", "name": "", "x": 38.69874038147765, "y": -122.37499407083057, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6abe982-a205-4607-bacf-08e9d7cb6f54", "name": "p1rdt456lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2c30f199-abfe-4d48-b1ca-b49cf7589e41"}}}}, {"uuid": "dd0efdae-a64f-41af-ba64-43b865c65806", "name": "", "x": 38.6988698234033, "y": -122.37507741848081, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33492e0f-c907-46c6-a529-503480b642bb", "name": "p1rlv837", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dd0efdae-a64f-41af-ba64-43b865c65806"}}}}, {"uuid": "0199de53-9365-434d-aa43-d2c1589ff2db", "name": "", "x": 38.69908332769086, "y": -122.37455807209501, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e3cae47a-4077-44e6-9761-fc30d85c3442", "name": "p1rdm822", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0199de53-9365-434d-aa43-d2c1589ff2db"}}}}, {"uuid": "e7862db2-6252-4c87-8f40-cc4b08525a6b", "name": "", "x": 38.699192938897575, "y": -122.3748331116339, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fbc761bf-480c-465c-9479-279832c50bc2", "name": "p1rlv779", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e7862db2-6252-4c87-8f40-cc4b08525a6b"}}}}, {"uuid": "fde861ab-384e-4d57-9c4b-8d29c452a1a4", "name": "", "x": 38.69872582718306, "y": -122.37511317064184, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "84ca6719-0bbc-440a-b0eb-23b8f32dcf47", "name": "p1rdm823", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fde861ab-384e-4d57-9c4b-8d29c452a1a4"}}}}, {"uuid": "a276efc9-12d7-4647-8126-ba4bf608023b", "name": "", "x": 38.69852447935862, "y": -122.37506494784137, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be4b6c4e-78d0-4c8e-907c-619f1e43c149", "name": "p1rlv831", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a276efc9-12d7-4647-8126-ba4bf608023b"}}}}, {"uuid": "dc7c9480-fff2-4481-9abb-71107106b522", "name": "", "x": 38.69449656825178, "y": -122.37575189359077, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "866745cc-62c9-429f-8389-fcc5a1710f17", "name": "p1rdt457lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dc7c9480-fff2-4481-9abb-71107106b522"}}}}, {"uuid": "fa6c14d6-12bd-4418-bb7c-5b75aabf228d", "name": "", "x": 38.69441132364952, "y": -122.37550717957821, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "20dcf67f-f04f-498a-830d-557ba7b4d867", "name": "p1rlv780", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa6c14d6-12bd-4418-bb7c-5b75aabf228d"}}}}, {"uuid": "845013de-0fa5-4507-86c0-0171eb46dab6", "name": "", "x": 38.694628638419935, "y": -122.3757007735009, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bf7e29df-0880-4c8c-aa5c-c43f24dd820e", "name": "p1rdm826", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "845013de-0fa5-4507-86c0-0171eb46dab6"}}}}, {"uuid": "4c292e42-91c1-425c-ab9d-78892c7e4836", "name": "", "x": 38.694609633506126, "y": -122.37551695428785, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2d1a96d5-f971-4116-9642-769ef5b97e7c", "name": "p1rlv783", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c292e42-91c1-425c-ab9d-78892c7e4836"}}}}, {"uuid": "be8d4ef3-4f9e-4921-94e3-a481ca49b2ff", "name": "", "x": 38.69466560426392, "y": -122.3758729377002, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eb137176-0642-4d87-ae40-1b7b0e1cb214", "name": "p1rlv795", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be8d4ef3-4f9e-4921-94e3-a481ca49b2ff"}}}}, {"uuid": "1a861ef0-a169-461f-abde-6f601141ce10", "name": "", "x": 38.694926011094644, "y": -122.37569818860291, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8fafab6a-7d1c-4b87-94b3-5bc4d09ff95d", "name": "p1rdm827", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1a861ef0-a169-461f-abde-6f601141ce10"}}}}, {"uuid": "01722373-7ba3-4bf0-a6df-8a4d2d2d63d4", "name": "", "x": 38.69489143888521, "y": -122.37597446682435, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3fe9bb3f-e3c1-4b59-b39f-f62271a55bdd", "name": "p1rlv791", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "01722373-7ba3-4bf0-a6df-8a4d2d2d63d4"}}}}, {"uuid": "9fc67f87-3522-4d69-a9a3-b9248ad5e601", "name": "", "x": 38.694187760198, "y": -122.37583109428404, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dc2d45e2-caa5-4f7d-976e-ccb045c30559", "name": "p1rdm829", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9fc67f87-3522-4d69-a9a3-b9248ad5e601"}}}}, {"uuid": "719b05d2-eba8-4118-9171-d1406b60336f", "name": "", "x": 38.694161769492204, "y": -122.3760268023747, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1ecc45b2-1fbe-4a31-995f-e2f8fffe61a7", "name": "p1rlv801", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "719b05d2-eba8-4118-9171-d1406b60336f"}}}}, {"uuid": "b6e99fb2-ec36-4ae6-9455-b941776f70f0", "name": "", "x": 38.69415358661105, "y": -122.37565138406234, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "11064c6f-3b7a-43b5-96ca-7ef96be3815e", "name": "p1rlv817", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b6e99fb2-ec36-4ae6-9455-b941776f70f0"}}}}, {"uuid": "f55d31ca-bc69-454e-8549-05d666f255d3", "name": "", "x": 38.695030276964474, "y": -122.37497283941411, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c668ab72-249e-4463-a3b4-863c7fe826c1", "name": "p1rdm831", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f55d31ca-bc69-454e-8549-05d666f255d3"}}}}, {"uuid": "ba483e47-e191-4d8f-aa43-0cdc306972f9", "name": "", "x": 38.69496811967224, "y": -122.37514586658888, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "98c5ba15-a339-478a-a79f-9298fab16a54", "name": "p1rlv781", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ba483e47-e191-4d8f-aa43-0cdc306972f9"}}}}, {"uuid": "b26f7ad4-878d-4d83-a117-65a1974f593c", "name": "", "x": 38.69490966180515, "y": -122.37485492226794, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "67e071ab-e3dc-4779-9e81-585547cd22ca", "name": "p1rdt458lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b26f7ad4-878d-4d83-a117-65a1974f593c"}}}}, {"uuid": "1c4ced69-d921-431e-a0ed-4f7bda33c6ce", "name": "", "x": 38.69482154193585, "y": -122.37469867853063, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "92f03cbf-2585-4e0e-ab0a-cda0b267b34d", "name": "p1rdm832", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1c4ced69-d921-431e-a0ed-4f7bda33c6ce"}}}}, {"uuid": "1da019c9-03b8-4947-aabc-fe8b39b50d8d", "name": "", "x": 38.69478038429, "y": -122.37489849683361, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c3bc013f-c78d-4a3c-b27f-826c3025de0e", "name": "p1rlv843", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1da019c9-03b8-4947-aabc-fe8b39b50d8d"}}}}, {"uuid": "379cb4d3-78c7-4221-af0f-e1a5b188a4bb", "name": "", "x": 38.701681041918285, "y": -122.37384145943425, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9eb57d99-ae80-43da-b0cb-b26bdd583e1a", "name": "p1rdt459lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "379cb4d3-78c7-4221-af0f-e1a5b188a4bb"}}}}, {"uuid": "e4637786-72a5-4382-96af-a9d4bb9b3ddd", "name": "", "x": 38.7019010899339, "y": -122.37401601985513, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "78a4f54a-017a-41b0-85c8-b3e408c21c08", "name": "p1rlv782", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e4637786-72a5-4382-96af-a9d4bb9b3ddd"}}}}, {"uuid": "77846b24-5292-42be-bdfc-2dd8cb5fe3f7", "name": "", "x": 38.70217626105635, "y": -122.37544717401559, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "028bc055-0ee6-4729-8cd2-15bd7153f975", "name": "p1rdt460lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "77846b24-5292-42be-bdfc-2dd8cb5fe3f7"}}}}, {"uuid": "b26c164b-bd1d-4e3b-b693-7687b88241a5", "name": "", "x": 38.70212578404628, "y": -122.37558959231082, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2823b5b9-bcc3-4b30-9874-89dc33ec80d2", "name": "p1rlv784", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b26c164b-bd1d-4e3b-b693-7687b88241a5"}}}}, {"uuid": "10c6883a-43b8-4c15-b651-d1ef7659c9b6", "name": "", "x": 38.702286881592116, "y": -122.37538118676348, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9b1c34f1-2613-46aa-9a9f-686ee518e559", "name": "p1rlv797", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10c6883a-43b8-4c15-b651-d1ef7659c9b6"}}}}, {"uuid": "b4b4ec33-db46-469e-a833-d5e498acc9ff", "name": "", "x": 38.702257020866284, "y": -122.37485243501904, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "790d0b88-fed2-4c90-bfdf-44d3c31d3d8d", "name": "p1rdm837", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b4b4ec33-db46-469e-a833-d5e498acc9ff"}}}}, {"uuid": "8295e92c-cbac-4f52-982a-bf37131d64d8", "name": "", "x": 38.70215746639765, "y": -122.37477280015747, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0d9f269a-e476-4b82-a258-479d812d008d", "name": "p1rlv806", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8295e92c-cbac-4f52-982a-bf37131d64d8"}}}}, {"uuid": "b98023ea-f8a2-432c-81a7-f05c1eec5f47", "name": "", "x": 38.702419502723, "y": -122.37467564114138, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e0e1d710-2ab1-43ca-a7c1-8f05a6c0b753", "name": "p1rdm835", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b98023ea-f8a2-432c-81a7-f05c1eec5f47"}}}}, {"uuid": "3396a052-4e10-4614-970a-e52b38290a46", "name": "", "x": 38.702500140978806, "y": -122.37481581739344, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "59662cef-c126-4188-ad86-844f6cabaf34", "name": "p1rlv796", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3396a052-4e10-4614-970a-e52b38290a46"}}}}, {"uuid": "e7917d2d-5f0a-4c8d-8ea2-3fd31c3312ae", "name": "", "x": 38.702324093645906, "y": -122.3755993680085, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "83fdcccd-6a26-4311-aad3-da67dac5af42", "name": "p1rdm838", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e7917d2d-5f0a-4c8d-8ea2-3fd31c3312ae"}}}}, {"uuid": "076990c7-d743-4fbb-89e1-5ebc4b093ce1", "name": "", "x": 38.70238649707223, "y": -122.37547232235222, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fb4a881f-684d-48e4-a6f0-5832f73d140a", "name": "p1rlv810", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "076990c7-d743-4fbb-89e1-5ebc4b093ce1"}}}}, {"uuid": "46076791-3910-4848-af07-6360ab1902cb", "name": "", "x": 38.70245104977729, "y": -122.37574776762911, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "344c24ef-9d54-4c1a-9aa4-852a76ddbec7", "name": "p1rdm839", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "46076791-3910-4848-af07-6360ab1902cb"}}}}, {"uuid": "364fe691-43cc-4586-8fbb-f3eed45bd625", "name": "", "x": 38.702223773417444, "y": -122.37590677054554, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d7ce197c-cee4-40df-b1d7-be13f1be8bb1", "name": "p1rlv822", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "364fe691-43cc-4586-8fbb-f3eed45bd625"}}}}, {"uuid": "69fe6bcf-63e7-4326-8de4-0eb763d1cef8", "name": "", "x": 38.70257800572197, "y": -122.37589616777406, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f0649432-ddb6-4648-8efe-27ee1fd959e4", "name": "p1rdm840", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "69fe6bcf-63e7-4326-8de4-0eb763d1cef8"}}}}, {"uuid": "e3ed841d-238a-473c-a6d8-4520609914f3", "name": "", "x": 38.70249776336369, "y": -122.37605786929961, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48e97be9-1f80-457f-a56e-79f54458c620", "name": "p1rlv839", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e3ed841d-238a-473c-a6d8-4520609914f3"}}}}, {"uuid": "fb47db4c-2eb8-46db-9d85-36ca6f7eac85", "name": "", "x": 38.69757588310151, "y": -122.37577864853107, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "505b390e-ffd3-482a-8ae9-b8d6bd8be94f", "name": "p1rdm841", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fb47db4c-2eb8-46db-9d85-36ca6f7eac85"}}}}, {"uuid": "7a77042f-fabf-48ca-b7bc-e10792c76c69", "name": "", "x": 38.69764123251456, "y": -122.37620356241798, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fa98d6c6-7086-4033-a9af-c0a33e802942", "name": "p1rlv785", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7a77042f-fabf-48ca-b7bc-e10792c76c69"}}}}, {"uuid": "f5f55bde-5e43-4018-86ad-8b885d9136a3", "name": "", "x": 38.697416472212836, "y": -122.37577251090494, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fd9a4931-435b-4b48-907c-024c0b8a4816", "name": "p1rdt461lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5f55bde-5e43-4018-86ad-8b885d9136a3"}}}}, {"uuid": "ebe1a657-73a9-459f-b0e0-fec2ca16456a", "name": "", "x": 38.69704403287731, "y": -122.37574877318404, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "172dd9d0-eab4-4481-9edd-f868e6ed87d9", "name": "p1rdm842", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ebe1a657-73a9-459f-b0e0-fec2ca16456a"}}}}, {"uuid": "3ccc8255-f565-4d1d-a03a-3ea1fc03d740", "name": "", "x": 38.69698334699525, "y": -122.37619777752667, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0e8c4bc9-0688-43e6-93a8-9664c9b618b7", "name": "p1rlv793", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3ccc8255-f565-4d1d-a03a-3ea1fc03d740"}}}}, {"uuid": "c0565ae7-3fec-4631-b6f3-a84c739859a2", "name": "", "x": 38.702201293623176, "y": -122.37338841314656, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d96f458-607c-4820-90b1-6fb2625ace7f", "name": "p1rdt462lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c0565ae7-3fec-4631-b6f3-a84c739859a2"}}}}, {"uuid": "117ffc96-232e-4015-aac7-6296e312ddff", "name": "", "x": 38.70221229583861, "y": -122.37323129022502, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bf42fa7f-370e-400e-8f6d-76eb8c70ecb9", "name": "p1rlv790", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "117ffc96-232e-4015-aac7-6296e312ddff"}}}}, {"uuid": "66ee1141-41be-44d4-b986-8ebb97d5a851", "name": "", "x": 38.702384188075854, "y": -122.3733562927121, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3ac64728-e64c-4241-8a3f-b884f11c6393", "name": "p1rdm843", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "66ee1141-41be-44d4-b986-8ebb97d5a851"}}}}, {"uuid": "860e4eab-613f-40e5-be26-b497bf4248c4", "name": "", "x": 38.70231135824942, "y": -122.37321892523424, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c9f470d9-6ead-4413-ad8a-7ccc69ae9237", "name": "p1rlv788", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "860e4eab-613f-40e5-be26-b497bf4248c4"}}}}, {"uuid": "dd8c6bac-9564-42dc-9c64-f3f6da327a3c", "name": "", "x": 38.7025463910665, "y": -122.37335487708582, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2086cded-e13c-4683-824e-9e15f99e12e8", "name": "p1rdm846", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dd8c6bac-9564-42dc-9c64-f3f6da327a3c"}}}}, {"uuid": "4c0f531e-29cb-4717-b893-ab2bbcda29c3", "name": "", "x": 38.70252953923245, "y": -122.37357352972886, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6e2a8871-7bc4-497f-9954-38db92cb3eba", "name": "p1rlv864", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c0f531e-29cb-4717-b893-ab2bbcda29c3"}}}}, {"uuid": "c59df0b4-eab3-43e2-9baa-fb2da89819cf", "name": "", "x": 38.702105331447335, "y": -122.37345072820672, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b4620a0-c781-422e-8cc7-3ceed9a0c8dc", "name": "p1rdm845", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c59df0b4-eab3-43e2-9baa-fb2da89819cf"}}}}, {"uuid": "f1970de7-55c0-4d65-a1ad-1d38a4180337", "name": "", "x": 38.70188944897217, "y": -122.37299658085036, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "024961c3-25f4-4a15-a52a-7f88dc652766", "name": "p1rlv840", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f1970de7-55c0-4d65-a1ad-1d38a4180337"}}}}, {"uuid": "c6c1d19e-c4b9-419a-a813-bc297120bd26", "name": "", "x": 38.702162992217495, "y": -122.3735922043492, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "abdfa5db-c398-4638-805d-6d55597e1921", "name": "p1rlv865", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c6c1d19e-c4b9-419a-a813-bc297120bd26"}}}}, {"uuid": "b294bc07-25bb-471e-adef-295df19ea6ae", "name": "", "x": 38.702251051988306, "y": -122.37373696284877, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1a7cca48-fd4b-4630-a479-55f2b6ada03b", "name": "p1rlv867", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b294bc07-25bb-471e-adef-295df19ea6ae"}}}}, {"uuid": "4ee440dd-1144-418b-b9e5-686ac95fe047", "name": "", "x": 38.70003035932669, "y": -122.37586478778037, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f660c35e-85f8-4f0e-b03b-806006c76c67", "name": "p1rdt463lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ee440dd-1144-418b-b9e5-686ac95fe047"}}}}, {"uuid": "6c8c6605-54a0-4f74-a558-cea62a6e6755", "name": "", "x": 38.7000284875326, "y": -122.37604482598387, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f806232e-0a52-46d5-80f7-7ea3a914137a", "name": "p1rlv792", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c8c6605-54a0-4f74-a558-cea62a6e6755"}}}}, {"uuid": "a1a9621f-11fc-426f-87dd-3d67019f0b3b", "name": "", "x": 38.699938225668625, "y": -122.37578973798107, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c397a5a5-21bc-4f4d-9f24-7af1219b70e7", "name": "p1rdm850", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a1a9621f-11fc-426f-87dd-3d67019f0b3b"}}}}, {"uuid": "28e708f2-3c1d-404d-8dcb-ecb29b51303c", "name": "", "x": 38.69980443234621, "y": -122.37627677000896, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bada1117-5605-4aec-9314-8013ed243e3c", "name": "p1rlv860", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "28e708f2-3c1d-404d-8dcb-ecb29b51303c"}}}}, {"uuid": "21cd6750-0958-4f0b-9fd8-b9f9372c0348", "name": "", "x": 38.69546877867281, "y": -122.373869079739, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "749e07aa-74ce-40f2-a352-9c55f9914377", "name": "p1rdt464lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "21cd6750-0958-4f0b-9fd8-b9f9372c0348"}}}}, {"uuid": "65f83ebc-aea0-429a-a6b4-dc69a6e34403", "name": "", "x": 38.6953493322175, "y": -122.37396963727394, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4eecc456-41af-4242-ab30-d8ca45d55a2c", "name": "p1rlv794", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65f83ebc-aea0-429a-a6b4-dc69a6e34403"}}}}, {"uuid": "efde92d7-4f87-4aa8-833a-398f86a5bcd0", "name": "", "x": 38.69564655774635, "y": -122.37393116894758, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "17b42dae-f856-4945-ba7a-9d3f47e049fe", "name": "p1rdm852", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "efde92d7-4f87-4aa8-833a-398f86a5bcd0"}}}}, {"uuid": "ede6db0e-440b-4e2d-8435-9539c4f9fe4c", "name": "", "x": 38.69550381660122, "y": -122.37420977320264, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d209dff6-7a24-41ef-947a-8c6f79c2d65c", "name": "p1rlv825", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ede6db0e-440b-4e2d-8435-9539c4f9fe4c"}}}}, {"uuid": "6c196105-5de5-4ebf-8534-5b9673501c2d", "name": "", "x": 38.69529421784077, "y": -122.37377463240384, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "08c93f8a-9600-4ffd-8e18-576d433ce777", "name": "p1rdm853", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c196105-5de5-4ebf-8534-5b9673501c2d"}}}}, {"uuid": "00f12ce4-6279-4f7f-b351-ef6b4d9d1895", "name": "", "x": 38.6954016143038, "y": -122.37363570614771, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8e3a1bd0-69fe-42bb-993d-2094ecc658ce", "name": "p1rlv829", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "00f12ce4-6279-4f7f-b351-ef6b4d9d1895"}}}}, {"uuid": "a12d289b-3eb4-436f-9fcb-4e06e31acedf", "name": "", "x": 38.6980078724581, "y": -122.37567139741331, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d5ad091a-3b6a-4069-a642-104c28a94dc4", "name": "p1rdm855", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a12d289b-3eb4-436f-9fcb-4e06e31acedf"}}}}, {"uuid": "e1b7c1d6-d5c9-416e-b644-68ca8ac89c67", "name": "", "x": 38.69804305798535, "y": -122.3755100974583, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e0f8ee8-795f-4bea-bf7a-e2c477eefb89", "name": "p1rlv809", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e1b7c1d6-d5c9-416e-b644-68ca8ac89c67"}}}}, {"uuid": "5f783c36-4d6c-46a7-a596-a1775597daf0", "name": "", "x": 38.69840981645937, "y": -122.37572585292882, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "433b0872-49c4-452c-941c-8083a72840ce", "name": "p1rdt465lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5f783c36-4d6c-46a7-a596-a1775597daf0"}}}}, {"uuid": "e28eaec9-f284-4eaf-8033-7359f6a39638", "name": "", "x": 38.69867415513827, "y": -122.37556210766509, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eaf112db-b9dc-4d90-b030-3e26188aaf2b", "name": "p1rdm856", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e28eaec9-f284-4eaf-8033-7359f6a39638"}}}}, {"uuid": "6f275d6c-b659-4a8f-9701-15a2f8ced9bc", "name": "", "x": 38.69855682418657, "y": -122.37552862894972, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d5e2c3a2-32c0-4bb9-9802-265cec784974", "name": "p1rlv862", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6f275d6c-b659-4a8f-9701-15a2f8ced9bc"}}}}, {"uuid": "13e20615-a6e4-4635-9781-ad96b92e29cd", "name": "", "x": 38.6988553632223, "y": -122.37574452723823, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eb73d9f2-aefb-430c-babd-ac02422eb212", "name": "p1rdm854", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "13e20615-a6e4-4635-9781-ad96b92e29cd"}}}}, {"uuid": "b48c379e-4147-4789-8a0b-4f78bd953f0b", "name": "", "x": 38.69885849252648, "y": -122.3763309850566, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c30005d7-7e42-4a08-8935-0c7227fba4a6", "name": "p1rlv798", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b48c379e-4147-4789-8a0b-4f78bd953f0b"}}}}, {"uuid": "b9e5cf5a-e99c-413d-b8a9-d68c8495cc17", "name": "", "x": 38.697834262777405, "y": -122.37522442460597, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c274aa99-a566-4915-83af-7115bec586b1", "name": "p1rdm857", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b9e5cf5a-e99c-413d-b8a9-d68c8495cc17"}}}}, {"uuid": "d06026e0-9130-4360-96b9-adbed16f39bd", "name": "", "x": 38.69763601444608, "y": -122.37522614936233, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6f706d9d-0cb1-453b-9ca5-377f7d766099", "name": "p1rlv799", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d06026e0-9130-4360-96b9-adbed16f39bd"}}}}, {"uuid": "d3d04da5-e3f9-4ba5-96af-05e7b20a1b7b", "name": "", "x": 38.69792563161655, "y": -122.37492861747332, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f422478c-0d77-48c8-87fb-e883d945f8a6", "name": "p1rdt466lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d3d04da5-e3f9-4ba5-96af-05e7b20a1b7b"}}}}, {"uuid": "6a7949b0-112b-4610-a8e8-2178e83b8af6", "name": "", "x": 38.69756758613625, "y": -122.37422628827595, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "caa7d639-522c-4fd6-8b74-73a337bd67d2", "name": "p1rdm858", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a7949b0-112b-4610-a8e8-2178e83b8af6"}}}}, {"uuid": "be08b287-4bce-4f87-b15e-4e011958954e", "name": "", "x": 38.69752942558697, "y": -122.37436063848634, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7a134556-828b-4e0c-8773-2f207802e33a", "name": "p1rlv815", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be08b287-4bce-4f87-b15e-4e011958954e"}}}}, {"uuid": "11ac6b38-60a5-49b9-8a0a-540db3fefb3c", "name": "", "x": 38.694252540223, "y": -122.37330828127818, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "23ed76af-dcb2-4333-ae4c-d7439a37cf87", "name": "p1rdt467lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "11ac6b38-60a5-49b9-8a0a-540db3fefb3c"}}}}, {"uuid": "d1963ecf-1914-499a-8472-b5247aebbf28", "name": "", "x": 38.69427815650523, "y": -122.37304358141793, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b2436086-d5c4-4b70-a402-e7d1b6f5b77e", "name": "p1rlv802", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1963ecf-1914-499a-8472-b5247aebbf28"}}}}, {"uuid": "3be967c7-0670-4f96-b81c-c29550a7414c", "name": "", "x": 38.695512481684965, "y": -122.37583108066667, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3a4bf0e0-92f0-4cd9-afc5-65d9ed242271", "name": "p1rdm861", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3be967c7-0670-4f96-b81c-c29550a7414c"}}}}, {"uuid": "efeb21c5-4624-459c-9e98-5cc05610708d", "name": "", "x": 38.69558659678035, "y": -122.3762099095591, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "81802469-7320-47e9-b826-fbb33bd371ab", "name": "p1rlv823", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "efeb21c5-4624-459c-9e98-5cc05610708d"}}}}, {"uuid": "033a2a11-14fb-4987-9143-4c5ea81d6861", "name": "", "x": 38.695386323591904, "y": -122.37583217708425, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3bfca289-c04c-45d9-8104-40089fc1737e", "name": "p1rdm860", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "033a2a11-14fb-4987-9143-4c5ea81d6861"}}}}, {"uuid": "a8f165ab-776e-40e3-8147-22b245234707", "name": "", "x": 38.6953513829787, "y": -122.3760394653489, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "018c978c-5673-4090-9792-b75ee161f6d2", "name": "p1rlv803", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8f165ab-776e-40e3-8147-22b245234707"}}}}, {"uuid": "a29fd963-e063-4256-9052-473ca445a911", "name": "", "x": 38.69564629017529, "y": -122.3756964667581, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b368fb8f-7f4d-4558-b6b2-2e1db4087727", "name": "p1rdt468lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a29fd963-e063-4256-9052-473ca445a911"}}}}, {"uuid": "f35e8328-37b1-44a2-a763-afa113575634", "name": "", "x": 38.696223821296954, "y": -122.37572140485321, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1daf402d-faec-4230-b4ab-1efa6283ac0f", "name": "p1rdm862", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f35e8328-37b1-44a2-a763-afa113575634"}}}}, {"uuid": "0c90b1a8-53a5-4b65-b599-aa1c94439206", "name": "", "x": 38.696252021310734, "y": -122.37593964620868, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2eb57fc4-636d-4923-9f4a-d308b062599f", "name": "p1rlv833", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0c90b1a8-53a5-4b65-b599-aa1c94439206"}}}}, {"uuid": "4c5c36ba-98c8-4540-bd20-b43167f47a63", "name": "", "x": 38.69464965312743, "y": -122.37341980651155, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d12ab15f-746d-462b-b395-e2b330ba1226", "name": "p1rdt469lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c5c36ba-98c8-4540-bd20-b43167f47a63"}}}}, {"uuid": "a5345d32-563a-4acd-b251-ba5e631ee422", "name": "", "x": 38.6946876894052, "y": -122.37326246422553, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0475b34e-14ab-48e4-9df7-7444de1cde7d", "name": "p1rlv805", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a5345d32-563a-4acd-b251-ba5e631ee422"}}}}, {"uuid": "087c125b-3c1d-4629-a9c6-0573dbf2e0c5", "name": "", "x": 38.70251978737086, "y": -122.37458961698891, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "15ab2647-a801-4cb5-a1f7-528118ff5dea", "name": "p1rdt470lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "087c125b-3c1d-4629-a9c6-0573dbf2e0c5"}}}}, {"uuid": "689170c1-88d4-43af-91c5-010c0ce51404", "name": "", "x": 38.70270494012969, "y": -122.37435402129528, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ab33ce2f-3131-4cfb-8df2-329fb4aa76b7", "name": "p1rlv858", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "689170c1-88d4-43af-91c5-010c0ce51404"}}}}, {"uuid": "f578b711-1e16-41bc-aea1-727982d2a44c", "name": "", "x": 38.70236818204675, "y": -122.3747179490724, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d861761c-3fe7-437d-917d-8beb24318a42", "name": "p1rdm864", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f578b711-1e16-41bc-aea1-727982d2a44c"}}}}, {"uuid": "186932a4-38ef-4136-bf3f-59f1cf536dfd", "name": "", "x": 38.702215723425525, "y": -122.37440030860232, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "aa259be8-8a61-461a-9e58-d4aaf1ce82db", "name": "p1rlv807", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "186932a4-38ef-4136-bf3f-59f1cf536dfd"}}}}, {"uuid": "0a7684b2-4e2a-4be3-aaf0-80e9592fb790", "name": "", "x": 38.701111976317726, "y": -122.37359342043746, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "40d98c0b-4c66-4581-9553-f5f57c4b27b9", "name": "p1rdt471lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a7684b2-4e2a-4be3-aaf0-80e9592fb790"}}}}, {"uuid": "85ea6224-1682-4dce-aec8-40cb358842c6", "name": "", "x": 38.7012040803456, "y": -122.37343559224011, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "06746d4d-3db8-45b1-888e-d3d9e405ccaf", "name": "p1rlv826", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "85ea6224-1682-4dce-aec8-40cb358842c6"}}}}, {"uuid": "50db1ac5-4754-41e4-9d37-bda897dc343b", "name": "", "x": 38.701232962213865, "y": -122.37378034278039, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "467753c6-5c1f-4a9d-8a7d-21419b25565f", "name": "p1rdm866", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "50db1ac5-4754-41e4-9d37-bda897dc343b"}}}}, {"uuid": "dedcff52-3cd3-467f-9c45-71a2c3e1ba7b", "name": "", "x": 38.70131313984175, "y": -122.37360714205926, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9dcb86a4-e6d7-48b4-b5c2-904635de271b", "name": "p1rlv808", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dedcff52-3cd3-467f-9c45-71a2c3e1ba7b"}}}}, {"uuid": "38d6ab03-3e7f-4fd9-883e-cfa2538e6a9f", "name": "", "x": 38.69441071978218, "y": -122.3742383194926, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f026a1d3-23b0-4454-a09b-e1c08cc06392", "name": "p1rdt472lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "38d6ab03-3e7f-4fd9-883e-cfa2538e6a9f"}}}}, {"uuid": "13e8ba29-89b7-4d05-a57a-3f34b24cc43e", "name": "", "x": 38.69453022804182, "y": -122.37414926221291, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6b4834dc-6bdf-4102-bc13-589392b2e75a", "name": "p1rlv866", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "13e8ba29-89b7-4d05-a57a-3f34b24cc43e"}}}}, {"uuid": "f2a7e3eb-ae43-49d8-b76c-8971895da950", "name": "", "x": 38.69435012529591, "y": -122.37417382958121, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f0ca3ea5-ad01-4e52-883a-c07805f613dd", "name": "p1rdm868", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f2a7e3eb-ae43-49d8-b76c-8971895da950"}}}}, {"uuid": "2576f1fb-b6fb-4af7-8366-e83fc7c59d2f", "name": "", "x": 38.69438573967901, "y": -122.37409302632886, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "26fea867-af5f-4213-b9c3-487975d1285e", "name": "p1rlv812", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2576f1fb-b6fb-4af7-8366-e83fc7c59d2f"}}}}, {"uuid": "7cbb35e7-df97-4165-aed4-3095857f8894", "name": "", "x": 38.69659862303915, "y": -122.37433121095306, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0aa0c31f-baa3-4db8-87d9-0a4ab9a83a8a", "name": "p1rdm870", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7cbb35e7-df97-4165-aed4-3095857f8894"}}}}, {"uuid": "c2ef7e3c-d290-41bb-8503-30c839028bfd", "name": "", "x": 38.69661091258349, "y": -122.37395864008647, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "10d44b60-55c0-4d78-abbb-52c8cd67134b", "name": "p1rlv813", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c2ef7e3c-d290-41bb-8503-30c839028bfd"}}}}, {"uuid": "a0e9fbf2-0b6f-4d7f-8873-daa40e499cae", "name": "", "x": 38.696471493549275, "y": -122.3743203106189, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1f435ec5-8c03-45ba-925b-83bad9501047", "name": "p1rdt473lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a0e9fbf2-0b6f-4d7f-8873-daa40e499cae"}}}}, {"uuid": "a099f1a8-ca54-48a4-85f5-70fbea769a79", "name": "", "x": 38.69629742532447, "y": -122.37431785096992, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "67c560cc-d815-41d4-8087-b66beaacb404", "name": "p1rdm871", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a099f1a8-ca54-48a4-85f5-70fbea769a79"}}}}, {"uuid": "d682dfc2-070f-47a5-a193-156d255f04d9", "name": "", "x": 38.6963229822717, "y": -122.37404164512883, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dd8c54fd-14d4-46fa-8bef-59c1097d5026", "name": "p1rlv818", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d682dfc2-070f-47a5-a193-156d255f04d9"}}}}, {"uuid": "d100526f-6d59-48eb-8c30-a2e68b037935", "name": "", "x": 38.695202937157, "y": -122.37577229914999, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "839858f4-3b18-40c3-86f3-e27225e6aba4", "name": "p1rdt474lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d100526f-6d59-48eb-8c30-a2e68b037935"}}}}, {"uuid": "cc9ae46b-eb99-4a30-b30b-6b6e84f4c59e", "name": "", "x": 38.695250110678316, "y": -122.37563787569754, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b8065f3-8286-4f99-aa56-b9b631a2f838", "name": "p1rlv814", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc9ae46b-eb99-4a30-b30b-6b6e84f4c59e"}}}}, {"uuid": "39fb4e3a-9f26-4cfc-9385-c44381ad05b3", "name": "", "x": 38.69519831370313, "y": -122.37606379343438, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1c89db91-40fe-4de6-973e-5d8c23e35080", "name": "p1rlv827", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "39fb4e3a-9f26-4cfc-9385-c44381ad05b3"}}}}, {"uuid": "9c3d2d3a-8524-4e4a-a0b2-c952bd788674", "name": "", "x": 38.69669246979562, "y": -122.37572883039154, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0ec705b7-fdaa-4eca-96eb-5dabb8256c78", "name": "p1rdm874", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9c3d2d3a-8524-4e4a-a0b2-c952bd788674"}}}}, {"uuid": "9eb67d1a-af44-45e3-8bdb-c4ad6a6e4c48", "name": "", "x": 38.696700867165035, "y": -122.37561376379026, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0d6de7c2-fd2c-4071-8e90-1513f521cf87", "name": "p1rlv816", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9eb67d1a-af44-45e3-8bdb-c4ad6a6e4c48"}}}}, {"uuid": "f6f806f4-f6c8-4acc-b5d4-dc9e58c721ea", "name": "", "x": 38.69688462197356, "y": -122.37574263565365, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1be3e20a-3890-4e9c-b568-ca99421e751c", "name": "p1rdt475lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f6f806f4-f6c8-4acc-b5d4-dc9e58c721ea"}}}}, {"uuid": "41f402a8-5a0d-43bb-92ca-31ba1dcfa4df", "name": "", "x": 38.69722432005433, "y": -122.37575870547994, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c17541ac-d30f-4f0a-9660-f9b9f7012b3a", "name": "p1rdm875", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "41f402a8-5a0d-43bb-92ca-31ba1dcfa4df"}}}}, {"uuid": "3d63d01d-b418-490e-98e2-bd17b4c6be29", "name": "", "x": 38.697222293760795, "y": -122.37537924143979, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d437c83c-cbd1-41bf-b455-21123e82d59f", "name": "p1rlv834", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3d63d01d-b418-490e-98e2-bd17b4c6be29"}}}}, {"uuid": "67a0c060-3859-4b1c-be3d-76b775d3991e", "name": "", "x": 38.70013424053621, "y": -122.37444144316905, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2ffde8c6-9dba-4f13-bda5-a0edf17c736d", "name": "p1rdt476lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "67a0c060-3859-4b1c-be3d-76b775d3991e"}}}}, {"uuid": "ced3b102-df6d-43e6-b894-4e4cf7a0fc03", "name": "", "x": 38.700172278057, "y": -122.37428408934844, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "12556ab7-c50a-4624-9d84-b85585822245", "name": "p1rlv836", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ced3b102-df6d-43e6-b894-4e4cf7a0fc03"}}}}, {"uuid": "6a4ba861-04bc-46c0-9877-3f78ef3e6dcc", "name": "", "x": 38.700326331213084, "y": -122.37444374611572, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f83e2ade-1911-4124-9fbe-6f482d68eba9", "name": "p1rdm878", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a4ba861-04bc-46c0-9877-3f78ef3e6dcc"}}}}, {"uuid": "650858b8-9d22-4882-8e53-a5090bc3e20b", "name": "", "x": 38.700363298980754, "y": -122.37461592326322, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e8f304a4-6e39-4288-9b9b-e41bb37c6019", "name": "p1rlv842", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "650858b8-9d22-4882-8e53-a5090bc3e20b"}}}}, {"uuid": "69c25aa2-cce5-47a1-bd11-f511d4e7ef98", "name": "", "x": 38.69999291375323, "y": -122.3744466507155, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "260b560c-e6d6-4069-b67f-067c468a7768", "name": "p1rdm879", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "69c25aa2-cce5-47a1-bd11-f511d4e7ef98"}}}}, {"uuid": "0b280d8d-3c4c-40e9-9412-11a35d68ccb0", "name": "", "x": 38.699967724899935, "y": -122.37479186664717, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "009758e3-b4ae-427a-9c30-f2a8bb2953d1", "name": "p1rlv868", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0b280d8d-3c4c-40e9-9412-11a35d68ccb0"}}}}, {"uuid": "74720137-2719-4bda-bd40-f1e0e83c7549", "name": "", "x": 38.69983071065769, "y": -122.37444806374667, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e5331a4f-ab91-4fea-a301-11b7afb6c8ca", "name": "p1rdm876", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "74720137-2719-4bda-bd40-f1e0e83c7549"}}}}, {"uuid": "4acdc884-dafb-47f0-9aef-0750c98c89a2", "name": "", "x": 38.69982305246386, "y": -122.37470112738258, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "41e1e576-4cc9-4fea-9d87-d436f000a675", "name": "p1rlv820", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4acdc884-dafb-47f0-9aef-0750c98c89a2"}}}}, {"uuid": "be4b1091-7833-463e-9423-9a59a5df48db", "name": "", "x": 38.70067167519556, "y": -122.37445621396152, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7c94703b-303a-4713-95c0-b2933fe0e70b", "name": "p1rdt477lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be4b1091-7833-463e-9423-9a59a5df48db"}}}}, {"uuid": "45c28223-7f02-491e-a73b-3b9744100bd2", "name": "", "x": 38.700632038038435, "y": -122.37431458299233, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5578d8b4-7c1e-444f-8d27-8c9bf733f420", "name": "p1rlv821", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "45c28223-7f02-491e-a73b-3b9744100bd2"}}}}, {"uuid": "ffdcebf1-e780-4f8b-91bb-fc038927b448", "name": "", "x": 38.700597838321514, "y": -122.37465988051781, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "08c3f5ef-c2d5-4ce2-8fc7-b665d8cbbab6", "name": "p1rlv828", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ffdcebf1-e780-4f8b-91bb-fc038927b448"}}}}, {"uuid": "f5cc1ded-e0f7-495c-ae2c-fbbe9b223fcf", "name": "", "x": 38.69822971347937, "y": -122.37575041780734, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c93c776d-68b8-4e4e-8e5e-d5e34003473c", "name": "p1rdt478lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5cc1ded-e0f7-495c-ae2c-fbbe9b223fcf"}}}}, {"uuid": "3f010d14-4b1e-42be-b585-e0ced44c54ea", "name": "", "x": 38.69822653688614, "y": -122.37611798096295, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "20ce76b6-9305-4525-b77e-b7300edc2c81", "name": "p1rlv824", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3f010d14-4b1e-42be-b585-e0ced44c54ea"}}}}, {"uuid": "ee288a4b-1410-407e-bb84-038feb7a9f5a", "name": "", "x": 38.70127438508099, "y": -122.37425546173934, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8037b713-d948-43c9-8370-fb8fcf6dec15", "name": "p1rdt479lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ee288a4b-1410-407e-bb84-038feb7a9f5a"}}}}, {"uuid": "eb04d832-c5da-4476-b767-3f3132f84fd6", "name": "", "x": 38.701326152810886, "y": -122.3743545350747, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "10373c0d-6a3c-4160-a174-22de447d4c38", "name": "p1rlv832", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eb04d832-c5da-4476-b767-3f3132f84fd6"}}}}, {"uuid": "8a561549-d427-4eb0-aff8-0cac6f22dd4a", "name": "", "x": 38.69561552385404, "y": -122.3739765254889, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "423402f9-4160-481b-9951-a955f8314075", "name": "p1rdt480lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8a561549-d427-4eb0-aff8-0cac6f22dd4a"}}}}, {"uuid": "58cd95d9-c795-4a7d-bf6a-852a7830e1c7", "name": "", "x": 38.69578897651805, "y": -122.37360932935272, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3bc35476-5839-4095-bea5-36e32450b890", "name": "p1rlv835", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "58cd95d9-c795-4a7d-bf6a-852a7830e1c7"}}}}, {"uuid": "1e7206f1-15d5-4231-864e-462f41dde77f", "name": "", "x": 38.69655114284914, "y": -122.37573403506332, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1761b021-00e0-4880-9f05-62cf67aef0e6", "name": "p1rdt481lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1e7206f1-15d5-4231-864e-462f41dde77f"}}}}, {"uuid": "cf2f06ed-eba1-449a-9286-5b45dc3920ec", "name": "", "x": 38.69650464427591, "y": -122.37599494765684, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4eb6c1b4-f09a-44a5-a13f-64051183736d", "name": "p1rlv841", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cf2f06ed-eba1-449a-9286-5b45dc3920ec"}}}}, {"uuid": "ea3ccfaa-4380-4f10-a9e3-de4b5e7d3502", "name": "", "x": 38.70357693514638, "y": -122.37510942987323, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c445ea76-5167-4d55-b0c5-cc53dadc5b5e", "name": "p1rdt482lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea3ccfaa-4380-4f10-a9e3-de4b5e7d3502"}}}}, {"uuid": "d417a786-cd49-46fd-ae63-d886ea429ad5", "name": "", "x": 38.70335811800441, "y": -122.37516485990416, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "26294827-db76-40b6-b652-1e41efdf15dc", "name": "p1rlv844", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d417a786-cd49-46fd-ae63-d886ea429ad5"}}}}, {"uuid": "0dab527d-342b-4f34-87fb-05ef650c3c36", "name": "", "x": 38.70345472163367, "y": -122.37469250108072, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3929a951-8b8b-42e9-a839-40c29e680108", "name": "p1rdm887", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0dab527d-342b-4f34-87fb-05ef650c3c36"}}}}, {"uuid": "d45f0194-8734-4ee3-9e7f-98f34d433fb6", "name": "", "x": 38.703250684927625, "y": -122.37476725706298, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "145d3757-ca09-45ca-9199-465b6b43fbb7", "name": "p1rlv846", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d45f0194-8734-4ee3-9e7f-98f34d433fb6"}}}}, {"uuid": "66e67166-f14a-476d-8648-058991b142e5", "name": "", "x": 38.70365739465258, "y": -122.37551877012066, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0318cdac-5c7b-4711-a0d7-9c7e104c8281", "name": "p1rdm888", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "66e67166-f14a-476d-8648-058991b142e5"}}}}, {"uuid": "a3ae50f4-d19a-4bfa-8ff0-1f84947d8884", "name": "", "x": 38.70348320380497, "y": -122.3754933077317, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e484d77-29ac-4903-afa3-f677283db883", "name": "p1rlv848", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a3ae50f4-d19a-4bfa-8ff0-1f84947d8884"}}}}, {"uuid": "dd460952-fe9a-4bfb-adf2-3abd1eaf4da5", "name": "", "x": 38.702921323422025, "y": -122.3755291486841, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "475b6a50-9814-4016-bb88-be5b1b2ac31d", "name": "p1rdt483lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dd460952-fe9a-4bfb-adf2-3abd1eaf4da5"}}}}, {"uuid": "b23389d5-db2a-42ee-8d67-2310f4899dc8", "name": "", "x": 38.703007845457876, "y": -122.37538641519177, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b053d449-b15b-4292-9a73-9b7d104a8e38", "name": "p1rlv845", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b23389d5-db2a-42ee-8d67-2310f4899dc8"}}}}, {"uuid": "240ea3e2-73c5-4635-bc37-fc108951680c", "name": "", "x": 38.70304524173173, "y": -122.37563909815356, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48b5535c-f00d-4b48-a23a-87f3f212302f", "name": "p1rlv851", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "240ea3e2-73c5-4635-bc37-fc108951680c"}}}}, {"uuid": "82a21e9b-7754-4024-88a0-ae654168e5df", "name": "", "x": 38.702817687028535, "y": -122.37521556434297, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5ea0f4f5-2024-45a8-9f8f-f5963e7d2727", "name": "p1rlv859", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "82a21e9b-7754-4024-88a0-ae654168e5df"}}}}, {"uuid": "669a2a11-e7f7-4f0e-b8c2-68e80fbec40b", "name": "", "x": 38.70279292587802, "y": -122.37564129224644, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "18ea7daf-9665-4d68-b255-12d41bdb2396", "name": "p1rdm892", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "669a2a11-e7f7-4f0e-b8c2-68e80fbec40b"}}}}, {"uuid": "5dc4e885-9a73-4f8e-b1ae-d50867b07dbb", "name": "", "x": 38.70291988195477, "y": -122.37578969289967, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "10611e08-75e2-4422-ac0f-cfb98c7eae4b", "name": "p1rlv855", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5dc4e885-9a73-4f8e-b1ae-d50867b07dbb"}}}}, {"uuid": "d4b2664f-dc7b-4cdb-b3b2-d960e5421cac", "name": "", "x": 38.70292245928232, "y": -122.37627268549726, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0398ef91-eeb8-4d34-b05e-e88adabdd487", "name": "p1rdm890", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d4b2664f-dc7b-4cdb-b3b2-d960e5421cac"}}}}, {"uuid": "2b9bff87-4eb3-4876-9012-61e1b232fe89", "name": "", "x": 38.703110285036146, "y": -122.37600654493566, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a95877ca-8600-4e95-82ac-c51cb82acf16", "name": "p1rlv849", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2b9bff87-4eb3-4876-9012-61e1b232fe89"}}}}, {"uuid": "9251def0-f2e1-4f6e-941b-d92daf95dca5", "name": "", "x": 38.703228109041184, "y": -122.37391642365674, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f396745a-5edb-4ab8-8bc7-2b181719cbf4", "name": "p1rdt484lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9251def0-f2e1-4f6e-941b-d92daf95dca5"}}}}, {"uuid": "49e501ea-9bde-4e92-adc9-d234bbe0089e", "name": "", "x": 38.703036634136346, "y": -122.3740291205105, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "283142ff-4884-4adc-9d4c-f8615505415a", "name": "p1rlv847", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "49e501ea-9bde-4e92-adc9-d234bbe0089e"}}}}, {"uuid": "fa8c24ff-8763-42d3-8d11-c9086c1ba728", "name": "", "x": 38.70327135825731, "y": -122.37410757698957, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e96e4c25-4664-45ae-b77c-9e0047f65c8b", "name": "p1rdm895", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa8c24ff-8763-42d3-8d11-c9086c1ba728"}}}}, {"uuid": "d321aa56-ea46-4547-b406-d12d6edaf433", "name": "", "x": 38.70311835119867, "y": -122.37414341195237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25f84b28-695b-4d32-b96c-914226444b9f", "name": "p1rlv856", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d321aa56-ea46-4547-b406-d12d6edaf433"}}}}, {"uuid": "7db6af4b-6a64-498f-a521-1854f01504d8", "name": "", "x": 38.703669352612835, "y": -122.37607068899858, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60637f4b-8538-4b21-988c-1b13adecc647", "name": "p1rdm896", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7db6af4b-6a64-498f-a521-1854f01504d8"}}}}, {"uuid": "b3c65356-acf8-47e2-8334-90564c73b6ca", "name": "", "x": 38.70391277989249, "y": -122.3760915746208, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f8d49057-9c70-4489-95bb-36b5b574e13d", "name": "p1rlv850", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b3c65356-acf8-47e2-8334-90564c73b6ca"}}}}, {"uuid": "e8a3be83-b908-4eb8-b9a2-4785c43e8598", "name": "", "x": 38.70359885298128, "y": -122.37627393150467, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "da38ec0a-f37d-4a5c-8da0-93410a8fb475", "name": "p1rdt485lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e8a3be83-b908-4eb8-b9a2-4785c43e8598"}}}}, {"uuid": "650cf4f4-5e7c-4f74-b727-66f7380cd60a", "name": "", "x": 38.703581080158116, "y": -122.37641646997498, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3464daa0-06b2-4d5d-9901-bb34050fe619", "name": "p1rdm897", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "650cf4f4-5e7c-4f74-b727-66f7380cd60a"}}}}, {"uuid": "42113e48-8448-48b0-9eb0-8fcced6b8af6", "name": "", "x": 38.703436102309, "y": -122.37626822341811, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "365eff25-8ccb-448b-894f-ad662fe6d684", "name": "p1rlv853", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "42113e48-8448-48b0-9eb0-8fcced6b8af6"}}}}, {"uuid": "05bc81c2-2d04-4cf3-a9a5-7f23fd30a9e3", "name": "", "x": 38.703390597071916, "y": -122.37449755221637, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9d9b6dee-73e1-43ab-ac9b-7d20fb77b6df", "name": "p1rdm898", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "05bc81c2-2d04-4cf3-a9a5-7f23fd30a9e3"}}}}, {"uuid": "7e983a28-7cb7-4af9-b2ce-4ffd390611f0", "name": "", "x": 38.70324715473682, "y": -122.37463680676714, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32142941-c546-4356-ba80-123b9128b5de", "name": "p1rlv852", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7e983a28-7cb7-4af9-b2ce-4ffd390611f0"}}}}, {"uuid": "897928d1-20b8-4749-8364-0b0632b5ca5a", "name": "", "x": 38.70348000850968, "y": -122.37489531232455, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5401d366-a5a2-4753-82b7-ce4fa08a1227", "name": "p1rdt486lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "897928d1-20b8-4749-8364-0b0632b5ca5a"}}}}, {"uuid": "4d064814-1c38-4d96-9a35-d3efdb32c61b", "name": "", "x": 38.70361123258167, "y": -122.37531216321483, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e5e11ab-e042-4038-85c4-162521871722", "name": "p1rdm899", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d064814-1c38-4d96-9a35-d3efdb32c61b"}}}}, {"uuid": "8ee66b9b-0ed0-4790-a55e-d4442e53b1b7", "name": "", "x": 38.703799916455935, "y": -122.3752070170666, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a28cc17a-125d-4b7b-a697-230e3f8853b5", "name": "p1rlv857", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8ee66b9b-0ed0-4790-a55e-d4442e53b1b7"}}}}, {"uuid": "738b4b76-6e5f-44ae-a070-587d3e0c8e90", "name": "", "x": 38.70291683599943, "y": -122.37353789637632, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "47fbd02f-6c12-4bd6-9d6d-2e0cddbfcd88", "name": "p1rdt487lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "738b4b76-6e5f-44ae-a070-587d3e0c8e90"}}}}, {"uuid": "db92746b-b776-4bb9-bdff-ba0791a8c89d", "name": "", "x": 38.702960786540345, "y": -122.373328259674, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2461b6f0-9a40-4b6f-9669-be479da039f3", "name": "p1rlv854", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "db92746b-b776-4bb9-bdff-ba0791a8c89d"}}}}, {"uuid": "eafb6508-d461-4b86-9216-758ab0e8ab85", "name": "", "x": 38.699795636236686, "y": -122.375786328938, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e517b810-e6b9-4c89-b47d-1921fcf88edc", "name": "p1rdt488lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eafb6508-d461-4b86-9216-758ab0e8ab85"}}}}, {"uuid": "b72997ac-862f-46db-a691-047ec1506a3f", "name": "", "x": 38.69977340921936, "y": -122.37552954904456, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "09a7be46-a1bf-459d-836b-beb64324809b", "name": "p1rlv863", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b72997ac-862f-46db-a691-047ec1506a3f"}}}}, {"uuid": "9b4b2a81-aca2-4dfe-b222-4bd3d89f2356", "name": "", "x": 38.699886904548684, "y": -122.37583204363513, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d7f4223-382b-4b9a-9157-baede39de271", "name": "p1rdm901", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9b4b2a81-aca2-4dfe-b222-4bd3d89f2356"}}}}, {"uuid": "d07a2474-09ad-4312-9dd3-89afa4b4b404", "name": "", "x": 38.699878813753116, "y": -122.37554765578757, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6a07d30f-6909-4d74-be8a-1ff8343b4419", "name": "p1rlv861", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d07a2474-09ad-4312-9dd3-89afa4b4b404"}}}}, {"uuid": "65525a66-1773-4ea2-b271-524a8bc99e2f", "name": "", "x": 38.69880247694915, "y": -122.37480953523237, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25637062-8ca3-4694-a27b-7be93e89fe1f", "name": "p1rdt489lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "65525a66-1773-4ea2-b271-524a8bc99e2f"}}}}, {"uuid": "3d4e34d0-f420-48ce-9811-dd970d236fa2", "name": "", "x": 38.698651585469364, "y": -122.37471132813891, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1fb4003d-498a-494d-89ca-f222d921f63a", "name": "p1rlv869", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3d4e34d0-f420-48ce-9811-dd970d236fa2"}}}}, {"uuid": "b6387c92-387a-45c9-87dc-051d39df6ccd", "name": "", "x": 38.759686999725254, "y": -122.44226913015365, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "601a7504-69fc-4c21-a1d8-1a59751d439c", "name": "p1rdm7860", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b6387c92-387a-45c9-87dc-051d39df6ccd"}}}}, {"uuid": "daba7bcc-f84f-4392-823d-cf77c8291e5e", "name": "", "x": 38.759611722163974, "y": -122.44160216619036, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fd7a84bb-8aa4-4668-9791-a363741823e9", "name": "p1rlv7783", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "daba7bcc-f84f-4392-823d-cf77c8291e5e"}}}}, {"uuid": "f417b4b4-aaed-4be9-aa1d-29ac29530106", "name": "", "x": 38.759987059360896, "y": -122.4422362456647, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8ae14df0-ab3b-47ba-9f83-c09f03999c76", "name": "p1rdt3776lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f417b4b4-aaed-4be9-aa1d-29ac29530106"}}}}, {"uuid": "3d1135bd-0816-4b36-bbc4-3735e50292b3", "name": "", "x": 38.760119212628396, "y": -122.44219670856471, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "391504f7-3b2f-47f0-aadd-47de5c89b16b", "name": "p1rdm7861", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3d1135bd-0816-4b36-bbc4-3735e50292b3"}}}}, {"uuid": "811d2f8e-757f-4164-9b75-2c45d474b794", "name": "", "x": 38.76011816883335, "y": -122.4419780350059, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "24e665a0-3ba6-46a7-bc02-327b6f77c409", "name": "p1rlv7784", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "811d2f8e-757f-4164-9b75-2c45d474b794"}}}}, {"uuid": "08c1e17d-fdf8-42ae-9eb9-e06c74feb269", "name": "", "x": 38.75891156323847, "y": -122.44466513486701, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4662f3f5-e75b-4b75-a6d6-7ada745d5cca", "name": "p1rdt3777lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "08c1e17d-fdf8-42ae-9eb9-e06c74feb269"}}}}, {"uuid": "44fc4fff-3b31-4f55-8b28-afc7b1803074", "name": "", "x": 38.75891004710453, "y": -122.44564742267218, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9af62e3c-9357-4505-a2f6-3b4252dab81b", "name": "p1rlv7786", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "44fc4fff-3b31-4f55-8b28-afc7b1803074"}}}}, {"uuid": "d07200f5-dcef-4fc8-b31d-44f9a58cb3af", "name": "", "x": 38.75892205855218, "y": -122.44438129888907, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "90158ee6-01aa-48ce-867f-8e459e7a5e09", "name": "p1rdm7862", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d07200f5-dcef-4fc8-b31d-44f9a58cb3af"}}}}, {"uuid": "2c94939f-e53a-4390-a61c-2fdeaf2224ef", "name": "", "x": 38.758813649325106, "y": -122.44432459271447, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1571d1a3-a151-4972-8cb1-aeb36b660abc", "name": "p1rlv7785", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2c94939f-e53a-4390-a61c-2fdeaf2224ef"}}}}, {"uuid": "2abed101-61b0-40f8-9656-14aa9bb44653", "name": "", "x": 38.665452782208654, "y": -122.46042242219686, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e734d7a2-9161-41c0-ba78-9f9f87120acd", "name": "p1rdt5098lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2abed101-61b0-40f8-9656-14aa9bb44653"}}}}, {"uuid": "349e93eb-bbeb-4cf6-962a-1da6b3e846fb", "name": "", "x": 38.66549109565642, "y": -122.46029967067366, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "09926231-b077-4aa6-afd8-acf89744865a", "name": "p1rlv10453", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "349e93eb-bbeb-4cf6-962a-1da6b3e846fb"}}}}, {"uuid": "ec821adf-cbe4-4f10-99c3-85668031f401", "name": "", "x": 38.665383753359855, "y": -122.46047289225729, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9a639e8d-ac8c-46e8-a4b5-6c551612b209", "name": "p1rlv10468", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ec821adf-cbe4-4f10-99c3-85668031f401"}}}}, {"uuid": "7096e027-1f66-45c2-8594-9b2f6171bb76", "name": "", "x": 38.665480227274244, "y": -122.45989744815324, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d40fc87f-1b73-4ed4-a397-dbc94312dcad", "name": "p1rlv10482", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7096e027-1f66-45c2-8594-9b2f6171bb76"}}}}, {"uuid": "1761a6d4-5d26-409e-b522-e6548258829b", "name": "", "x": 38.665521469030836, "y": -122.46102359049253, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "efd01236-6ba3-424e-829b-3f3950ce6265", "name": "p1rlv10517", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1761a6d4-5d26-409e-b522-e6548258829b"}}}}, {"uuid": "9dc653ac-d7a4-4f89-a699-b360eff11ffe", "name": "", "x": 38.65349301133138, "y": -122.48412729471077, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "91754be7-2a91-4a0e-9856-43d08ecc7c70", "name": "p1rdt5548lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9dc653ac-d7a4-4f89-a699-b360eff11ffe"}}}}, {"uuid": "32548a03-8760-4329-b730-0eb4180d6402", "name": "", "x": 38.65285475188867, "y": -122.48386195652688, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "773a6b9e-d708-4f7c-a901-9406bcc3dcde", "name": "p1rlv11503", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "32548a03-8760-4329-b730-0eb4180d6402"}}}}, {"uuid": "6daffc64-545f-48b6-b9dd-c01a7caf0cd9", "name": "", "x": 38.65294527277444, "y": -122.48395324626152, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f7efbb32-55d4-409b-a37f-bf01d0620d40", "name": "p1rlv19645", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6daffc64-545f-48b6-b9dd-c01a7caf0cd9"}}}}, {"uuid": "d52b4ce6-a2a9-4d89-b20c-badbd780ff8b", "name": "", "x": 38.65351451941317, "y": -122.48429393725958, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c4c77c78-e261-4d17-93ff-caad4d86246b", "name": "p1rdm11706", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d52b4ce6-a2a9-4d89-b20c-badbd780ff8b"}}}}, {"uuid": "5c8ae331-4dc1-4b73-8eb7-19d3d44f688f", "name": "", "x": 38.65313573125618, "y": -122.48422769840043, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9e90f763-682e-4771-976c-9cd736b72133", "name": "p1rlv19640", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5c8ae331-4dc1-4b73-8eb7-19d3d44f688f"}}}}, {"uuid": "e12efe67-ffe9-45e6-8d49-c58f292ff6e8", "name": "", "x": 38.65401139999537, "y": -122.48253201007375, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "15ae4af0-db43-4f1b-bd8c-c6be31d034aa", "name": "p1rdm11719", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e12efe67-ffe9-45e6-8d49-c58f292ff6e8"}}}}, {"uuid": "3ba0dc35-2b37-4a80-ade1-eac0f9902e85", "name": "", "x": 38.65384898920333, "y": -122.48248720829615, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "84b9d44e-2c8d-4cee-a9d2-327a41ab8dad", "name": "p1rlv11513", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3ba0dc35-2b37-4a80-ade1-eac0f9902e85"}}}}, {"uuid": "0bf7988f-5ebc-458b-826c-ec6efad5e132", "name": "", "x": 38.65406486613757, "y": -122.48238206755065, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "05b867e6-2f18-49e7-9869-55bd5048c201", "name": "p1rdt5557lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0bf7988f-5ebc-458b-826c-ec6efad5e132"}}}}, {"uuid": "dcf43b02-4298-41d4-ad1c-92d87578993e", "name": "", "x": 38.654054728485086, "y": -122.4821409504333, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "effa94d0-34ae-4cbe-b8da-fd1693d47b3a", "name": "p1rdm11720", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dcf43b02-4298-41d4-ad1c-92d87578993e"}}}}, {"uuid": "4931ad26-9e32-4cb4-85cd-f7485acc5477", "name": "", "x": 38.65329740432264, "y": -122.48206595565533, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bf457d88-958c-446a-9584-73be8c609bbe", "name": "p1rlv19574", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4931ad26-9e32-4cb4-85cd-f7485acc5477"}}}}, {"uuid": "f173e132-e022-46a1-b3cf-6fb8b348146f", "name": "", "x": 38.655212268996365, "y": -122.4810200626239, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d5838960-8556-4e4a-95e9-8ba9ffc85141", "name": "p1rdt5560lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f173e132-e022-46a1-b3cf-6fb8b348146f"}}}}, {"uuid": "edd6a9c5-95e0-4cbc-9328-cd8be4f904c6", "name": "", "x": 38.655330800417374, "y": -122.48132726741721, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "86d82a1e-1596-4fb3-9f3d-44c9553396d2", "name": "p1rlv11516", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "edd6a9c5-95e0-4cbc-9328-cd8be4f904c6"}}}}, {"uuid": "3fcef969-b8f3-49c8-ad03-1838c6eac971", "name": "", "x": 38.65375449158675, "y": -122.48352206240394, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "133a0221-0cd5-46d2-af84-e80e7951c96d", "name": "p1rdt5561lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3fcef969-b8f3-49c8-ad03-1838c6eac971"}}}}, {"uuid": "5a41b4bf-e666-4b1b-834e-521504b72b04", "name": "", "x": 38.65442296031636, "y": -122.48389667390005, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "179d1d84-0dfe-4920-a039-009f33bc1d8d", "name": "p1rlv11517", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5a41b4bf-e666-4b1b-834e-521504b72b04"}}}}, {"uuid": "2f613491-2ee1-4f3f-9d9a-e20f2d3640a5", "name": "", "x": 38.65445021577995, "y": -122.48126863552662, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8deb73b9-51fc-447d-9da7-14a6dccff646", "name": "p1rdt5564lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2f613491-2ee1-4f3f-9d9a-e20f2d3640a5"}}}}, {"uuid": "5397d76e-8423-4b26-b76a-ed3deff45a7c", "name": "", "x": 38.65452001830409, "y": -122.48139057750333, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f8f0f8a2-f528-45bd-8fbd-22f6699fe7e0", "name": "p1rlv11521", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5397d76e-8423-4b26-b76a-ed3deff45a7c"}}}}, {"uuid": "d1eb9046-a524-4a94-b3ce-001d80998cd8", "name": "", "x": 38.653503595754145, "y": -122.48459005947156, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "95a5450a-6630-41b8-863f-0c1f3fcfa7ab", "name": "p1rdt5566lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1eb9046-a524-4a94-b3ce-001d80998cd8"}}}}, {"uuid": "c57fc713-783d-4b5e-a8bc-8461f19caa7a", "name": "", "x": 38.652722315413676, "y": -122.48448349500988, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "69eba934-3f80-4abc-b5e8-9cdc79aa05a3", "name": "p1rlv11523", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c57fc713-783d-4b5e-a8bc-8461f19caa7a"}}}}, {"uuid": "bb4f6529-f339-4286-bf82-44fc21a9adef", "name": "", "x": 38.65290868561374, "y": -122.48312227902461, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "613d178b-a566-408d-bad0-e4a170eea971", "name": "p1rdt5568lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bb4f6529-f339-4286-bf82-44fc21a9adef"}}}}, {"uuid": "317c2a79-f30d-438a-93a0-556de85f2806", "name": "", "x": 38.65290346928153, "y": -122.48306882713341, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b97ebb0-09a4-4c42-a10e-e3aff344aa44", "name": "p1rlv11526", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "317c2a79-f30d-438a-93a0-556de85f2806"}}}}, {"uuid": "aff86a89-8b6f-444c-a1a3-218129998f5b", "name": "", "x": 38.6535709305957, "y": -122.48453866803233, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0460a67f-dcc1-4829-99f8-7a0b6a8cedbc", "name": "p1rdm11742", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aff86a89-8b6f-444c-a1a3-218129998f5b"}}}}, {"uuid": "3e312389-c9f7-417a-be1e-7d41819eff67", "name": "", "x": 38.652965879895014, "y": -122.48453921146539, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "21b18539-fba6-4b52-b8bf-38c2a6c4abfb", "name": "p1rlv11533", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e312389-c9f7-417a-be1e-7d41819eff67"}}}}, {"uuid": "f3df1aff-a25f-42fd-82d9-c0e51c70bc8f", "name": "", "x": 38.65330877367878, "y": -122.48464018641775, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8f0e181a-fa89-4c5d-a1cb-6080f91331da", "name": "p1rlv19643", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f3df1aff-a25f-42fd-82d9-c0e51c70bc8f"}}}}, {"uuid": "6e5af62d-2fbe-4dfd-b7d1-8a1040a5ab7e", "name": "", "x": 38.65345372369736, "y": -122.48479084547154, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "248e065d-80ed-4926-9625-295c83da6b61", "name": "p1rdt5574lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6e5af62d-2fbe-4dfd-b7d1-8a1040a5ab7e"}}}}, {"uuid": "981c76fc-50f5-4e40-ae36-c33893f91beb", "name": "", "x": 38.65346288080924, "y": -122.48484594711942, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6554d73d-5cf7-4531-a524-78e70b36fd8d", "name": "p1rdm11743", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "981c76fc-50f5-4e40-ae36-c33893f91beb"}}}}, {"uuid": "365c2b7e-424c-4246-8ec1-4d1f39dbbcbb", "name": "", "x": 38.65324635107003, "y": -122.48479003561559, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "813f887e-6807-4ffc-90bf-bd30cde9a9df", "name": "p1rlv19610", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "365c2b7e-424c-4246-8ec1-4d1f39dbbcbb"}}}}, {"uuid": "e1ac22f0-6134-44d1-8d4f-f2948df6203a", "name": "", "x": 38.65211076864418, "y": -122.48360342410952, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "21ef4ae6-b80e-49f1-8d00-1cb6e27bc8f9", "name": "p1rdt5577lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e1ac22f0-6134-44d1-8d4f-f2948df6203a"}}}}, {"uuid": "c8697d6c-15d8-4c61-a6de-4f056fdb7afb", "name": "", "x": 38.65211742852992, "y": -122.48423500000004, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1148946c-8c37-4482-afce-5082cd2b7ad4", "name": "p1rdt5577lv-p1rlv11540x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c8697d6c-15d8-4c61-a6de-4f056fdb7afb"}}}}, {"uuid": "53948b43-71df-47cc-80ba-c157d05bf7d7", "name": "", "x": 38.65207242155051, "y": -122.48424681497777, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f79b14c8-e77d-49c1-9336-e7407ad4c94d", "name": "p1rlv11540", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "53948b43-71df-47cc-80ba-c157d05bf7d7"}}}}, {"uuid": "2a1c2b55-25ee-42cc-8a93-81ebf49aae00", "name": "", "x": 38.65279916105022, "y": -122.4835175838475, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "752bcf04-7a44-42b0-9a46-44c243b78eb5", "name": "p1rdt5577lv-p1rlv19608x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2a1c2b55-25ee-42cc-8a93-81ebf49aae00"}}}}, {"uuid": "bcf33a8f-8984-4542-a3db-d89c5f01df6e", "name": "", "x": 38.652193358258536, "y": -122.48306224209226, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f917b142-d59f-4a51-8c3b-913feb53411d", "name": "p1rlv19608", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bcf33a8f-8984-4542-a3db-d89c5f01df6e"}}}}, {"uuid": "4483501b-cdce-4aa1-833e-1d89f54498eb", "name": "", "x": 38.66703472717699, "y": -122.47875999417263, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a5559c15-cdac-4a4d-a2a0-b99c9befb310", "name": "p1rdm13355", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4483501b-cdce-4aa1-833e-1d89f54498eb"}}}}, {"uuid": "8e65ba3a-d5dc-4516-9dcc-39816f28eb6c", "name": "", "x": 38.666963198566314, "y": -122.47888695389291, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1564c5f9-8b80-41b4-af09-2a55dee0718b", "name": "p1rlv13033", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8e65ba3a-d5dc-4516-9dcc-39816f28eb6c"}}}}, {"uuid": "358567fb-7670-4972-bc4a-8361e82ef171", "name": "", "x": 38.66717310843214, "y": -122.47884342821176, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a9859b30-0238-493e-be1a-cb6717413ba9", "name": "p1rdt6261lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "358567fb-7670-4972-bc4a-8361e82ef171"}}}}, {"uuid": "9605bc5c-3d00-4414-ba84-af1384312959", "name": "", "x": 38.667278908257714, "y": -122.47895363367641, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ba5e6363-0b23-4726-8013-f3d040511005", "name": "p1rdm13356", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9605bc5c-3d00-4414-ba84-af1384312959"}}}}, {"uuid": "d06077af-253f-4440-a72d-e4097453ec3e", "name": "", "x": 38.66717220353242, "y": -122.4792762580999, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "23aae8f1-8b9f-4453-9643-b49ffdc80889", "name": "p1rlv13036", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d06077af-253f-4440-a72d-e4097453ec3e"}}}}, {"uuid": "1edf8d84-7823-4da1-a9cf-7d60fa171495", "name": "", "x": 38.66655673727605, "y": -122.48006632205775, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c2172b57-622b-44c1-8388-f1e2b1def312", "name": "p1rdt6262lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1edf8d84-7823-4da1-a9cf-7d60fa171495"}}}}, {"uuid": "e08f8ab0-1195-4113-aad2-d08a9ef594fb", "name": "", "x": 38.66654421125099, "y": -122.47991300856037, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3b7bff1-90da-4ee2-8a0f-8e291a7e8ac8", "name": "p1rlv13034", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e08f8ab0-1195-4113-aad2-d08a9ef594fb"}}}}, {"uuid": "cc8e6a88-7c99-4b4d-a6a2-b5b5983b91f3", "name": "", "x": 38.66654838989604, "y": -122.48021581199129, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c6839f65-9d3b-4bd6-89a4-0c8feb33e98a", "name": "p1rlv13040", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc8e6a88-7c99-4b4d-a6a2-b5b5983b91f3"}}}}, {"uuid": "ff16a8d5-a522-4782-b3a5-3bae4ab23764", "name": "", "x": 38.66690377458573, "y": -122.48086176489268, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4717b000-fd39-4647-9fbd-5152323dacee", "name": "p1rdt6263lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ff16a8d5-a522-4782-b3a5-3bae4ab23764"}}}}, {"uuid": "1220e772-0453-4a0b-b571-cc0a62841ce9", "name": "", "x": 38.66687779947186, "y": -122.48081912313049, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c6d309ef-b082-4022-a265-4891cdcd6db9", "name": "p1rlv13035", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1220e772-0453-4a0b-b571-cc0a62841ce9"}}}}, {"uuid": "03fd6629-3635-4d50-8480-1e1e39c348ec", "name": "", "x": 38.66255558019544, "y": -122.47741013877915, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e916c16-525d-4092-b627-ad44b4bf4ee8", "name": "p1rdt6264lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "03fd6629-3635-4d50-8480-1e1e39c348ec"}}}}, {"uuid": "5b083b59-faa7-407f-94c6-95a8fb7db4e9", "name": "", "x": 38.66254447908395, "y": -122.47746230770055, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7f5d04aa-74fb-4d1a-ac91-6c01a56a94b5", "name": "p1rlv13037", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5b083b59-faa7-407f-94c6-95a8fb7db4e9"}}}}, {"uuid": "f42abcc6-9394-4f6f-afa6-91874259a980", "name": "", "x": 38.66061026704863, "y": -122.48036217979423, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e6bb5544-e583-4ded-9a10-23be70f5598e", "name": "p1rdt6265lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f42abcc6-9394-4f6f-afa6-91874259a980"}}}}, {"uuid": "c47455e5-7a81-46e7-8b23-13a1b138d9b2", "name": "", "x": 38.660735364357585, "y": -122.48075957945385, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9a8b4502-31fd-4dce-8717-9860880075b4", "name": "p1rlv13038", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c47455e5-7a81-46e7-8b23-13a1b138d9b2"}}}}, {"uuid": "768cb989-5a66-410d-bed8-df0e10c19744", "name": "", "x": 38.660452382345134, "y": -122.47994557664096, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "34d43081-e4a3-4f1b-8b90-5965458452d0", "name": "p1rlv13039", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "768cb989-5a66-410d-bed8-df0e10c19744"}}}}, {"uuid": "c00988a8-164a-4ae9-87ff-eda2c2eb1e48", "name": "", "x": 38.66246119968208, "y": -122.47659512275703, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8af5f9d5-965c-4a0c-a811-67d3bed744ee", "name": "p1rdt6266lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c00988a8-164a-4ae9-87ff-eda2c2eb1e48"}}}}, {"uuid": "c8e8dfff-c156-4d84-b476-8dbf65fb2e45", "name": "", "x": 38.66248671917567, "y": -122.47655203872152, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60144ce1-d4d6-4725-b543-f881894356a5", "name": "p1rlv13041", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c8e8dfff-c156-4d84-b476-8dbf65fb2e45"}}}}, {"uuid": "62fb1dd6-10cf-453b-a9db-bf538e6415e4", "name": "", "x": 38.6652765486321, "y": -122.4794367281912, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d0ddd898-3193-4bff-80f4-fd4a7eae9aec", "name": "p1rdt6267lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "62fb1dd6-10cf-453b-a9db-bf538e6415e4"}}}}, {"uuid": "74b1a318-c73f-40ae-a0e6-13095293a6a8", "name": "", "x": 38.665302069155366, "y": -122.47939364345397, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "296cd07e-c2e3-4031-abad-9c870a65105d", "name": "p1rlv13042", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "74b1a318-c73f-40ae-a0e6-13095293a6a8"}}}}, {"uuid": "f4e4a449-0026-4c8d-b73e-666ad21ff0e4", "name": "", "x": 38.64756555827549, "y": -122.50910380696413, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b1155c2c-544c-45f4-969f-b3ec4f6773bb", "name": "p1rdt6488lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f4e4a449-0026-4c8d-b73e-666ad21ff0e4"}}}}, {"uuid": "941c708e-42ff-43af-9af5-da57099f33ff", "name": "", "x": 38.647565542168486, "y": -122.50904985776398, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3243ca2f-a97e-4fbc-981d-85eded2e5e6b", "name": "p1rlv13513", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "941c708e-42ff-43af-9af5-da57099f33ff"}}}}, {"uuid": "59de6cf1-c8b9-4799-9a3e-2d4543e023f1", "name": "", "x": 38.66460136270918, "y": -122.44791156272083, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "555453a3-3fb7-426a-bbd2-9e588d4bd01d", "name": "p1rdt6578lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59de6cf1-c8b9-4799-9a3e-2d4543e023f1"}}}}, {"uuid": "73222e13-9809-4b5b-b542-81f2e9da8236", "name": "", "x": 38.66482282070209, "y": -122.4484080912382, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b0ca6e47-afec-4d61-885a-e38176b32444", "name": "p1rlv13823", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "73222e13-9809-4b5b-b542-81f2e9da8236"}}}}, {"uuid": "89f1ffe4-82cc-44f4-b229-a1afaf6f6224", "name": "", "x": 38.66450541345186, "y": -122.44798523933892, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b2fe65b3-6fcc-4416-bca4-9a0f6551b801", "name": "p1rdm14192", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "89f1ffe4-82cc-44f4-b229-a1afaf6f6224"}}}}, {"uuid": "3480b5cb-c591-42d2-9162-b0b478d1a56f", "name": "", "x": 38.664643133522475, "y": -122.44852441239391, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "47a7519a-b550-41e6-99e3-c2115db425fe", "name": "p1rlv13789", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3480b5cb-c591-42d2-9162-b0b478d1a56f"}}}}, {"uuid": "05f1416d-d004-448f-b835-8e7320ea9e88", "name": "", "x": 38.664533911991846, "y": -122.4482953651979, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "94ac9254-cdbf-4864-b22b-bcfb0a827700", "name": "p1rlv13796", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "05f1416d-d004-448f-b835-8e7320ea9e88"}}}}, {"uuid": "91603163-b327-419b-a562-9c486068b876", "name": "", "x": 38.66474807177311, "y": -122.44784544493244, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e0be7c1-65b8-4de4-89f2-56b6bf1ea321", "name": "p1rdm14194", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "91603163-b327-419b-a562-9c486068b876"}}}}, {"uuid": "51acf417-9cd8-46f7-97c9-1dcf69d8d859", "name": "", "x": 38.664827245819765, "y": -122.44803626546826, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "028d5ead-7c34-400b-bcc1-c4d706c965d3", "name": "p1rlv13814", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "51acf417-9cd8-46f7-97c9-1dcf69d8d859"}}}}, {"uuid": "99ed1f5c-706f-4524-beb7-df5068132667", "name": "", "x": 38.66661910169782, "y": -122.45155134514903, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5de250a8-ecca-4ab4-9f09-685aaf92d13d", "name": "p1rdt6580lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "99ed1f5c-706f-4524-beb7-df5068132667"}}}}, {"uuid": "c929ea7a-c3b7-4391-8edc-8285bd035f71", "name": "", "x": 38.666738131523914, "y": -122.4513475088475, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "251f270f-4238-4fe6-8ab3-f884fca7a42d", "name": "p1rlv13791", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c929ea7a-c3b7-4391-8edc-8285bd035f71"}}}}, {"uuid": "b64d8094-1b15-4af2-acb7-1e043d25b76f", "name": "", "x": 38.66668551808711, "y": -122.45165826434774, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ab29ca66-d59b-4aa6-b5f6-165add0bc331", "name": "p1rlv13810", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b64d8094-1b15-4af2-acb7-1e043d25b76f"}}}}, {"uuid": "52721818-3941-4aff-9668-b15d64e4bdbd", "name": "", "x": 38.666731383536465, "y": -122.45183033352055, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "99957459-46a6-4b2b-9813-69b11ca7dad1", "name": "p1rlv13815", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "52721818-3941-4aff-9668-b15d64e4bdbd"}}}}, {"uuid": "247043b9-09d5-4c87-b578-344fd897a004", "name": "", "x": 38.66641388074643, "y": -122.4513844669654, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "36c12a74-a2ca-439a-a69f-308dd5cb1207", "name": "p1rlv13819", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "247043b9-09d5-4c87-b578-344fd897a004"}}}}, {"uuid": "ea0e7b78-57d9-4a45-8c88-1895800c3377", "name": "", "x": 38.66518206185532, "y": -122.44754723338062, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4d944119-3782-49dd-8b24-1f68d8ee687c", "name": "p1rdt6584lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea0e7b78-57d9-4a45-8c88-1895800c3377"}}}}, {"uuid": "d1cbf045-63a5-47f4-8bc1-deba3702bf62", "name": "", "x": 38.66553515936385, "y": -122.4484945814938, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e96bcc5b-07c5-4289-aec4-0224395c5e8a", "name": "p1rlv13817", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1cbf045-63a5-47f4-8bc1-deba3702bf62"}}}}, {"uuid": "a2f9db05-7e24-4244-8ad2-e1510b25c7d1", "name": "", "x": 38.664864895136674, "y": -122.44777558197904, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "39af24f1-0fa2-465e-a288-2b620d9e9d59", "name": "p1rdm14215", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a2f9db05-7e24-4244-8ad2-e1510b25c7d1"}}}}, {"uuid": "feda626a-d10e-404b-8da3-429c769d4502", "name": "", "x": 38.66522828205339, "y": -122.4483934862407, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "accec892-a236-462d-b714-1178393ec992", "name": "p1rlv13801", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "feda626a-d10e-404b-8da3-429c769d4502"}}}}, {"uuid": "8c3e1a23-2e50-4e2b-bd42-b64588a6a090", "name": "", "x": 38.66526883647157, "y": -122.44743914288946, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "32db643a-7c82-4816-8629-7935cab09567", "name": "p1rdm14218", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8c3e1a23-2e50-4e2b-bd42-b64588a6a090"}}}}, {"uuid": "3993ede8-b98b-4f7e-8582-45a688300ddf", "name": "", "x": 38.66568002523225, "y": -122.4480376675357, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6ade9991-a857-4619-8094-c18f824aaeb9", "name": "p1rlv13822", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3993ede8-b98b-4f7e-8582-45a688300ddf"}}}}, {"uuid": "c957710d-5b59-48d4-a705-163d7bef81c0", "name": "", "x": 38.665376485198, "y": -122.44733486613728, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e81f150f-30cd-4c9a-b5b7-7a633633702d", "name": "p1rdm14216", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c957710d-5b59-48d4-a705-163d7bef81c0"}}}}, {"uuid": "0640235f-69e2-44df-a002-75850f23e028", "name": "", "x": 38.66561322577763, "y": -122.44785029518839, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c26fba44-3b81-47de-81e6-522f2daf0534", "name": "p1rlv13807", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0640235f-69e2-44df-a002-75850f23e028"}}}}, {"uuid": "9a67951a-5d21-4aaf-8cf1-055c0e9b6ed4", "name": "", "x": 38.6660700064695, "y": -122.44833835279438, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9c587698-7940-4edb-9105-f31f1304f7e9", "name": "p1rdt6587lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9a67951a-5d21-4aaf-8cf1-055c0e9b6ed4"}}}}, {"uuid": "94a40471-e692-4c82-9db0-8a67ada7ed7d", "name": "", "x": 38.66604401958438, "y": -122.44829572341504, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1c795ac7-3b49-4158-996d-2fb1f0337847", "name": "p1rlv13808", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "94a40471-e692-4c82-9db0-8a67ada7ed7d"}}}}, {"uuid": "fa34ac6d-08b7-48d7-a2f6-0fb2f91ccd62", "name": "", "x": 38.665782733034895, "y": -122.44688743442987, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "61045f72-ca3d-4e0d-ac3d-db5fbf099b38", "name": "p1rdt6588lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa34ac6d-08b7-48d7-a2f6-0fb2f91ccd62"}}}}, {"uuid": "18f4c8ab-3825-40dd-ae7c-e806892501d8", "name": "", "x": 38.66551610253854, "y": -122.44636826305491, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "687996da-ab03-4544-b0d9-b79b8ac88e95", "name": "p1rlv13809", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "18f4c8ab-3825-40dd-ae7c-e806892501d8"}}}}, {"uuid": "774d8c44-6377-428c-89ae-01326c5972f4", "name": "", "x": 38.66470818578833, "y": -122.44621086682648, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a289017a-8ab9-4412-857a-694b3aa2c63d", "name": "p1rdt6590lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "774d8c44-6377-428c-89ae-01326c5972f4"}}}}, {"uuid": "aca2fbd4-467d-4bf7-8341-2b23f9d30c2b", "name": "", "x": 38.66472254581389, "y": -122.44626167635215, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a2caa70b-9143-4676-834b-bfc7cb41330c", "name": "p1rlv13820", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aca2fbd4-467d-4bf7-8341-2b23f9d30c2b"}}}}, {"uuid": "51a9a4f7-cb5d-4fe5-9213-71fe12585bae", "name": "", "x": 38.66450288065584, "y": -122.44662624081425, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8a7c2e99-857f-4119-be4a-daaca586f056", "name": "p1rdt6591lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "51a9a4f7-cb5d-4fe5-9213-71fe12585bae"}}}}, {"uuid": "bd002735-2c22-4505-9f8a-7fed31956b37", "name": "", "x": 38.664476893151246, "y": -122.44658361298364, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "66e6c732-919a-4851-9f76-5580ea71669d", "name": "p1rlv13821", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bd002735-2c22-4505-9f8a-7fed31956b37"}}}}, {"uuid": "53ce4353-6591-4b16-8c1b-6a572722d9d2", "name": "", "x": 38.650925590961236, "y": -122.47648370205337, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8ad975da-cce7-49cb-be78-20c4abf8975e", "name": "p1rdt7286lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "53ce4353-6591-4b16-8c1b-6a572722d9d2"}}}}, {"uuid": "1f533a6b-7428-41c4-9100-81e5b64c526d", "name": "", "x": 38.65091178622824, "y": -122.47653475192051, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "17bf6d8f-8215-4294-b921-cc3e34476f1e", "name": "p1rlv15585", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1f533a6b-7428-41c4-9100-81e5b64c526d"}}}}, {"uuid": "7bd1bc68-a2a4-45a5-8c9c-3c8b6a13e850", "name": "", "x": 38.650690731688435, "y": -122.47687130836174, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "56d21681-3c57-4575-af17-f2bbf9874a10", "name": "p1rdt7289lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7bd1bc68-a2a4-45a5-8c9c-3c8b6a13e850"}}}}, {"uuid": "ab2a10f9-9b8c-4c25-a988-03a6d071f099", "name": "", "x": 38.6509152754639, "y": -122.47733687713344, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ef2a4478-4644-4bd3-9548-ab1d0be338b5", "name": "p1rlv15590", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ab2a10f9-9b8c-4c25-a988-03a6d071f099"}}}}, {"uuid": "9baa86b9-b0df-4541-ad87-bc928134642d", "name": "", "x": 38.650433450846926, "y": -122.47639803350314, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c04c9ad1-4277-47de-9cec-9ce86e17b4f1", "name": "p1rlv15591", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9baa86b9-b0df-4541-ad87-bc928134642d"}}}}, {"uuid": "c5d952d0-6fca-404d-bafd-c21da4301161", "name": "", "x": 38.64948736383664, "y": -122.47579982496423, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a9b0c16f-f433-4aa1-8d00-dc1573dfb5e3", "name": "p1rdt7293lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c5d952d0-6fca-404d-bafd-c21da4301161"}}}}, {"uuid": "90c36dbe-020f-474a-abb4-c1e99f474701", "name": "", "x": 38.64940610565797, "y": -122.47576594155083, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "629e2259-2a59-4b20-b8bf-7b3b2c4a48f9", "name": "p1rlv15595", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "90c36dbe-020f-474a-abb4-c1e99f474701"}}}}, {"uuid": "cee60e10-1306-4dec-9856-0151cfeda93e", "name": "", "x": 38.64955676013305, "y": -122.47582982129457, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "af6b7d1b-896f-44ac-8038-748c74507253", "name": "p1rlv15598", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cee60e10-1306-4dec-9856-0151cfeda93e"}}}}, {"uuid": "15fe8ec5-07e2-4234-a2a7-51372760b4ae", "name": "", "x": 38.654450185149294, "y": -122.50266398158654, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2c1ea087-8a4d-49ca-af35-b86aed849c98", "name": "p1rdm16003", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "15fe8ec5-07e2-4234-a2a7-51372760b4ae"}}}}, {"uuid": "a779adaf-c56f-4ee1-b671-6b1ebacd5ed8", "name": "", "x": 38.65486320126965, "y": -122.50230485132435, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1ae1bbf1-459f-4346-b525-393b7d1dc958", "name": "p1rlv15599", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a779adaf-c56f-4ee1-b671-6b1ebacd5ed8"}}}}, {"uuid": "6c968024-4d09-403e-8de9-24c501753797", "name": "", "x": 38.65438386391856, "y": -122.5025685251368, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e67d2b31-f05a-4160-83ae-55154224a9ca", "name": "p1rdt7294lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c968024-4d09-403e-8de9-24c501753797"}}}}, {"uuid": "3a8505e3-0148-40ca-8dea-f61cc48f9601", "name": "", "x": 38.65435022729933, "y": -122.50246929784952, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "84040096-aca8-4cee-8539-83ae8f875e98", "name": "p1rdm16004", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3a8505e3-0148-40ca-8dea-f61cc48f9601"}}}}, {"uuid": "1214be7e-500a-4096-ad98-58bc00c5743b", "name": "", "x": 38.65468208995729, "y": -122.50209923605257, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "200aa7d8-0a43-4086-b0e7-f63cae75671d", "name": "p1rlv15618", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1214be7e-500a-4096-ad98-58bc00c5743b"}}}}, {"uuid": "fb368e45-5c62-4a91-958e-6df0c1eec86a", "name": "", "x": 38.653703111752435, "y": -122.50076138596326, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "381018f1-11cd-4519-ad24-d3419116ea84", "name": "p1rdm16011", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fb368e45-5c62-4a91-958e-6df0c1eec86a"}}}}, {"uuid": "eb97ab60-a0ad-46ff-81c6-1ab952ef9d01", "name": "", "x": 38.653216389940184, "y": -122.5007417792492, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "95b45d46-b7e7-46e2-98d9-5034e2fa0a17", "name": "p1rlv15604", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eb97ab60-a0ad-46ff-81c6-1ab952ef9d01"}}}}, {"uuid": "6432a19e-5501-4437-a6b0-cd8612d69898", "name": "", "x": 38.65369179013314, "y": -122.5008839086118, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4cee417a-3410-4907-8621-f0d3fcbc047c", "name": "p1rdt7299lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6432a19e-5501-4437-a6b0-cd8612d69898"}}}}, {"uuid": "799f4d77-24d9-4527-bf0a-c0834026128f", "name": "", "x": 38.653722262619546, "y": -122.50102558146277, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60d0a9cf-54f3-4049-9957-29839b7beb08", "name": "p1rdm16012", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "799f4d77-24d9-4527-bf0a-c0834026128f"}}}}, {"uuid": "ff26d6fb-1052-422a-81b1-50b88edd8bbd", "name": "", "x": 38.65323563888248, "y": -122.5010289572013, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "43ed408e-35e2-4bca-9060-a0c211aea1e7", "name": "p1rlv15616", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ff26d6fb-1052-422a-81b1-50b88edd8bbd"}}}}, {"uuid": "dc6d07f1-791e-4b94-9a88-dbf295621c02", "name": "", "x": 38.65171836396122, "y": -122.5073219402769, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "135a6a49-6562-4c6e-a41f-f5f78c0ac3e6", "name": "p1rdt7300lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dc6d07f1-791e-4b94-9a88-dbf295621c02"}}}}, {"uuid": "d1113cbb-086c-48b3-8046-8852b680c9f0", "name": "", "x": 38.65167635588258, "y": -122.5073274367839, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dcbee2ff-bf73-4834-bc3c-46fa0cfcad7c", "name": "p1rlv15605", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1113cbb-086c-48b3-8046-8852b680c9f0"}}}}, {"uuid": "dd0c9180-337b-4bc7-a31a-2e7577171c37", "name": "", "x": 38.65243771052424, "y": -122.50266243015153, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7cbc8145-b198-46f1-a3fd-55a05637e618", "name": "p1rdt7303lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dd0c9180-337b-4bc7-a31a-2e7577171c37"}}}}, {"uuid": "73ce9fe1-705c-4d8e-80a9-5002c8210d4b", "name": "", "x": 38.65185163082318, "y": -122.5019234602924, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "13d6bce6-9066-43a1-b2b6-00a2a4398958", "name": "p1rlv15608", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "73ce9fe1-705c-4d8e-80a9-5002c8210d4b"}}}}, {"uuid": "c3756008-99bf-4ec0-be53-adb1369cb151", "name": "", "x": 38.65403878438859, "y": -122.50195031171204, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f5094655-6494-44a9-b0ff-c5b418dcc11e", "name": "p1rdt7308lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c3756008-99bf-4ec0-be53-adb1369cb151"}}}}, {"uuid": "381a41d9-1504-45db-8a4a-b27efaca3000", "name": "", "x": 38.65437369075951, "y": -122.50163017248886, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "905a4857-5d3d-4e51-9ab0-70d634170f92", "name": "p1rlv15619", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "381a41d9-1504-45db-8a4a-b27efaca3000"}}}}, {"uuid": "4fbcffd8-86e8-496d-a8d0-357e53dacafa", "name": "", "x": 38.65414032051154, "y": -122.50185014901611, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4363602a-eb9c-41b8-8130-7bb839f4eb5a", "name": "p1rlv15641", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4fbcffd8-86e8-496d-a8d0-357e53dacafa"}}}}, {"uuid": "8d28b870-3e9d-4d30-9b6a-31be9b81e034", "name": "", "x": 38.65415951784417, "y": -122.50212583870878, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2fba947f-089b-47f3-8720-e8f3e35c097c", "name": "p1rdm16029", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8d28b870-3e9d-4d30-9b6a-31be9b81e034"}}}}, {"uuid": "6011a0aa-03d4-41bc-9cd5-35dc2c621d40", "name": "", "x": 38.65402792759886, "y": -122.50230311224807, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "13f790a1-18c0-498f-8525-fbaf0350947b", "name": "p1rlv15623", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6011a0aa-03d4-41bc-9cd5-35dc2c621d40"}}}}, {"uuid": "7bcce16d-87e0-4d10-8d57-fc5b8f524a87", "name": "", "x": 38.65396880738655, "y": -122.5017823813949, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "154999cc-f6d5-458a-8504-e4692344d372", "name": "p1rdm16030", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7bcce16d-87e0-4d10-8d57-fc5b8f524a87"}}}}, {"uuid": "ced6ff7a-a03f-4dbf-af5e-aade5a1de2b0", "name": "", "x": 38.654067738651435, "y": -122.50173572574505, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bb08eda2-b277-4bfd-9ea0-9c36765400bd", "name": "p1rlv15625", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ced6ff7a-a03f-4dbf-af5e-aade5a1de2b0"}}}}, {"uuid": "ada35336-5f78-4415-b3ea-9cc7c7352964", "name": "", "x": 38.65379214946685, "y": -122.49984533771044, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a289e26d-2d86-4fdf-942b-881b91ca18eb", "name": "p1rdt7316lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ada35336-5f78-4415-b3ea-9cc7c7352964"}}}}, {"uuid": "f1c90b98-2c9f-413b-b598-8e9a43a467cb", "name": "", "x": 38.653302578004016, "y": -122.49982178319588, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ccbef4c-6bf7-4892-a3b9-b51aca495137", "name": "p1rlv15632", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f1c90b98-2c9f-413b-b598-8e9a43a467cb"}}}}, {"uuid": "9249d58e-8a76-44e5-ab7a-bbf6e295e37f", "name": "", "x": 38.65235598284797, "y": -122.5051810906482, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16c465cf-c4ae-4702-ba6c-0b7704eda764", "name": "p1rdt7317lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9249d58e-8a76-44e5-ab7a-bbf6e295e37f"}}}}, {"uuid": "4cde1297-67a1-4116-829e-576e190346d1", "name": "", "x": 38.65233001653422, "y": -122.50513844857348, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ce7b60c8-43ee-441d-9f18-5b2722dcc0a7", "name": "p1rlv15633", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4cde1297-67a1-4116-829e-576e190346d1"}}}}, {"uuid": "36a11850-ce0c-4dc2-9025-e1a728e855f8", "name": "", "x": 38.65388017043282, "y": -122.50146517734701, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c855f7bb-1f33-4c3e-9deb-e3f9c5aba07d", "name": "p1rdt7321lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "36a11850-ce0c-4dc2-9025-e1a728e855f8"}}}}, {"uuid": "70d3109c-f76c-4c96-a280-3e806f70f125", "name": "", "x": 38.654218486038864, "y": -122.50116005048001, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "83c2de51-1b04-483c-8ce7-14b9e5e027b9", "name": "p1rlv15640", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "70d3109c-f76c-4c96-a280-3e806f70f125"}}}}, {"uuid": "540b9bcf-c9d5-4cb2-8966-7c8b6f1c4e02", "name": "", "x": 38.65226101532919, "y": -122.47461094321253, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35be767a-53a1-4fe1-b320-9542dd859d97", "name": "p1rdt7737lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "540b9bcf-c9d5-4cb2-8966-7c8b6f1c4e02"}}}}, {"uuid": "9128b7b1-69e3-423d-ab24-0b8fb59a92b2", "name": "", "x": 38.652194262671, "y": -122.47453893224326, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f5f1e7aa-d93a-4164-8bc0-f920259304a8", "name": "p1rlv16450", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9128b7b1-69e3-423d-ab24-0b8fb59a92b2"}}}}, {"uuid": "45717d17-588c-4eb9-a4be-b1c9e571652a", "name": "", "x": 38.65248920521251, "y": -122.47462474258207, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d9c505d7-3fb9-4eb5-89c6-c9c8da32fd05", "name": "p1rlv16463", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "45717d17-588c-4eb9-a4be-b1c9e571652a"}}}}, {"uuid": "0576c8e0-7b96-4420-b9f8-447650c20d43", "name": "", "x": 38.652235798683144, "y": -122.47438525528987, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "27afe70a-9123-4b0c-9f50-b5355aafcf7a", "name": "p1rlv16507", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0576c8e0-7b96-4420-b9f8-447650c20d43"}}}}, {"uuid": "ea134be6-84da-486d-a0fb-15deb4c9bca9", "name": "", "x": 38.652238275903315, "y": -122.4749368672296, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "344c6b21-94c9-4912-a19e-69fbae5eed27", "name": "p1rlv16584", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea134be6-84da-486d-a0fb-15deb4c9bca9"}}}}, {"uuid": "82e95af2-0e57-4cfe-9c63-c699df52bc84", "name": "", "x": 38.65261600612352, "y": -122.47400628819638, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c7482f0c-eb85-4e30-a09a-eb9f15bbc22b", "name": "p1rdt7753lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "82e95af2-0e57-4cfe-9c63-c699df52bc84"}}}}, {"uuid": "f0d43a70-8ec5-408b-bb0e-9092293d6456", "name": "", "x": 38.652627105759464, "y": -122.4739541259785, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d400b1b2-8404-4b80-b110-6f96e000314f", "name": "p1rlv16475", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f0d43a70-8ec5-408b-bb0e-9092293d6456"}}}}, {"uuid": "83cbec58-3089-49b8-91b1-3572e4a05cab", "name": "", "x": 38.658298169770895, "y": -122.47497347035102, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d343e634-0936-4f21-9e2c-079e19f0dfa1", "name": "p1rdt7757lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "83cbec58-3089-49b8-91b1-3572e4a05cab"}}}}, {"uuid": "b74099d8-228c-463c-a617-41b1b8d455ef", "name": "", "x": 38.65825842964543, "y": -122.47499635592735, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fa6db7ee-126d-4aa9-9733-35ff1c1d5992", "name": "p1rlv16483", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b74099d8-228c-463c-a617-41b1b8d455ef"}}}}, {"uuid": "05f73af5-dbf7-4f27-99c1-3a2dcde31799", "name": "", "x": 38.65819457523532, "y": -122.47482442341177, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0333a34b-4027-4d9a-9d4a-f867c8a317bc", "name": "p1rlv16530", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "05f73af5-dbf7-4f27-99c1-3a2dcde31799"}}}}, {"uuid": "9256eb4c-375b-42f1-8ad0-bcc74e8ae8d9", "name": "", "x": 38.658358587646056, "y": -122.4752254901639, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2f7be042-6681-4694-872d-a1cb701016c7", "name": "p1rlv16541", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9256eb4c-375b-42f1-8ad0-bcc74e8ae8d9"}}}}, {"uuid": "55908553-18e6-47d5-8215-e9cf09c30dea", "name": "", "x": 38.65188446678294, "y": -122.47516262760837, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "28e5f84f-2fac-4b5c-a669-b16988e4d6ae", "name": "p1rdt7791lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "55908553-18e6-47d5-8215-e9cf09c30dea"}}}}, {"uuid": "3e84f813-0859-4f02-bd54-f544f2df4bd7", "name": "", "x": 38.65192675650909, "y": -122.47516097998692, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "90d9dbe9-f9c9-4a4e-8ada-cb459778687b", "name": "p1rlv16573", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e84f813-0859-4f02-bd54-f544f2df4bd7"}}}}, {"uuid": "04928077-4f80-411d-97b8-360cb32be1a4", "name": "", "x": 38.65926840087407, "y": -122.47227383933975, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3959f944-18f5-4daa-a454-3c6bfb7158ff", "name": "p1rdt7795lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "04928077-4f80-411d-97b8-360cb32be1a4"}}}}, {"uuid": "1c69b90b-d0e1-4028-b482-1ca4036e8cc5", "name": "", "x": 38.659242422649335, "y": -122.47223120521224, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4f9ecb3f-8b64-4598-a9d1-d794c6800d33", "name": "p1rlv16604", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1c69b90b-d0e1-4028-b482-1ca4036e8cc5"}}}}, {"uuid": "3a49aadf-859f-4e49-b74b-d23355a7ffe5", "name": "", "x": 38.65559599442719, "y": -122.48692988350368, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b2ec0ba-a854-4631-b97a-4674123d6fe6", "name": "p1rdt8105lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3a49aadf-859f-4e49-b74b-d23355a7ffe5"}}}}, {"uuid": "4ed7c063-ce74-4874-bf3b-1cec6aacd6f6", "name": "", "x": 38.65559859235702, "y": -122.4868763747223, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ba567aae-a893-41d3-8fd1-8357d3cab35d", "name": "p1rlv17239", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ed7c063-ce74-4874-bf3b-1cec6aacd6f6"}}}}, {"uuid": "8ded3db0-024b-49be-9acc-a695799cecde", "name": "", "x": 38.65564415406407, "y": -122.48699097808593, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ac80cbea-e10a-491a-ba36-06e9fcf74217", "name": "p1rlv17280", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8ded3db0-024b-49be-9acc-a695799cecde"}}}}, {"uuid": "e0f12590-98d4-4ed7-88fc-5fa5e8fe6dff", "name": "", "x": 38.65331243461887, "y": -122.48752476984971, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d3a01639-0851-466b-abc6-adf52342e772", "name": "p1rdm17827", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e0f12590-98d4-4ed7-88fc-5fa5e8fe6dff"}}}}, {"uuid": "e1d2445b-e46e-4799-9c98-9252d8c2b600", "name": "", "x": 38.652961085543296, "y": -122.48755025792832, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "acfdbe95-2d82-463a-9d1f-6fd2688adf16", "name": "p1rlv17246", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e1d2445b-e46e-4799-9c98-9252d8c2b600"}}}}, {"uuid": "1bb45f7b-4b3a-4a44-9f4d-3048f9a15419", "name": "", "x": 38.65328712796407, "y": -122.48771232590543, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b639e55-2e33-4582-bb96-06a9d33a3419", "name": "p1rdt8111lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1bb45f7b-4b3a-4a44-9f4d-3048f9a15419"}}}}, {"uuid": "7da01a9e-f940-4a01-ac34-2a764e845b0c", "name": "", "x": 38.653333923034495, "y": -122.48782204194723, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5f70da59-a879-487b-802e-6b7158e425ca", "name": "p1rdm17828", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7da01a9e-f940-4a01-ac34-2a764e845b0c"}}}}, {"uuid": "a34da1cb-8ad8-4e47-b317-055a6b86c735", "name": "", "x": 38.65282666757047, "y": -122.4877236014364, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "04eb7e32-e372-4cb0-94a7-ee418f400bda", "name": "p1rlv17303", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a34da1cb-8ad8-4e47-b317-055a6b86c735"}}}}, {"uuid": "494046db-61b9-449a-9a55-d9608b0d5234", "name": "", "x": 38.65208064789989, "y": -122.48678276121687, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dca9b40e-ed8a-4f75-a703-91539f6c3075", "name": "p1rdt8138lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "494046db-61b9-449a-9a55-d9608b0d5234"}}}}, {"uuid": "7c64b2fd-a133-4a8c-9fcb-743e9393fa45", "name": "", "x": 38.65203864087114, "y": -122.4867882697381, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "04388b89-16fc-40b3-a060-5bc52032874e", "name": "p1rlv17291", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7c64b2fd-a133-4a8c-9fcb-743e9393fa45"}}}}, {"uuid": "1088c6d5-a0f6-4aec-b76a-562b554e8ef7", "name": "", "x": 38.65325699793473, "y": -122.48785970145335, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2bee3961-990e-47ac-b49b-d305f8fe0af8", "name": "p1rdt8146lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1088c6d5-a0f6-4aec-b76a-562b554e8ef7"}}}}, {"uuid": "56ebb882-ddef-4c87-b835-7a021bf78079", "name": "", "x": 38.65356656926306, "y": -122.48793668955402, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "84ebd9bb-dc50-483d-a3c6-044682d4020c", "name": "p1rlv17311", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "56ebb882-ddef-4c87-b835-7a021bf78079"}}}}, {"uuid": "c69bb444-8523-4fdb-99e3-e8c089f4c256", "name": "", "x": 38.66673594751398, "y": -122.46980033939064, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa", "name": "p1rdt8167lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c69bb444-8523-4fdb-99e3-e8c089f4c256"}}}}, {"uuid": "b5629075-98c4-481e-8592-5d57793c505c", "name": "", "x": 38.66651447553529, "y": -122.46928074240148, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8ead5953-70f2-4db2-ba4d-d203c91d85c1", "name": "p1rlv17345", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b5629075-98c4-481e-8592-5d57793c505c"}}}}, {"uuid": "098d3ef0-d2ce-45d0-b04b-b6fa2a56d0b0", "name": "", "x": 38.66618245827339, "y": -122.4695935453166, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf6f74e5-7aa3-4333-bd37-3ce486d54a01", "name": "p1rlv17357", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "098d3ef0-d2ce-45d0-b04b-b6fa2a56d0b0"}}}}, {"uuid": "688ea7b2-7e09-464c-9685-92079311bc8a", "name": "", "x": 38.6673297300225, "y": -122.47020579507135, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d38cdffb-41be-48aa-8a03-c6525dd01037", "name": "p1rlv17397", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "688ea7b2-7e09-464c-9685-92079311bc8a"}}}}, {"uuid": "3dc7dadf-fb8b-4fe0-bf61-9116073c4629", "name": "", "x": 38.66639617857814, "y": -122.46902873548488, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "63177299-2842-4e0d-bf17-7bd2b0afe9a2", "name": "p1rlv17400", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3dc7dadf-fb8b-4fe0-bf61-9116073c4629"}}}}, {"uuid": "ad90541b-98b5-45cd-aea6-3f4573d2327e", "name": "", "x": 38.66678976962103, "y": -122.47037069875277, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b50de14e-9a09-4f61-8998-0979f33b0d0a", "name": "p1rlv17405", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ad90541b-98b5-45cd-aea6-3f4573d2327e"}}}}, {"uuid": "43488034-d332-485e-b8da-3a24da45e181", "name": "", "x": 38.66709595196411, "y": -122.47032246448548, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "86b2527b-73c3-41c4-8ac2-7cb0e8bc2a7a", "name": "p1rlv17415", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "43488034-d332-485e-b8da-3a24da45e181"}}}}, {"uuid": "ff26a39a-d362-48b4-b352-4a4d2839995a", "name": "", "x": 38.66477303429095, "y": -122.46767335323095, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6349165a-d47a-4cf4-84f9-df5c5f3a0e98", "name": "p1rdt8169lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ff26a39a-d362-48b4-b352-4a4d2839995a"}}}}, {"uuid": "443ccb79-9a64-4ac3-b93f-fa60e82b93dd", "name": "", "x": 38.66481200983204, "y": -122.467465715666, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d98640c6-d8aa-44e4-9ecf-5998152d3f7d", "name": "p1rlv17347", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "443ccb79-9a64-4ac3-b93f-fa60e82b93dd"}}}}, {"uuid": "f004f264-53e5-4fd1-8448-926cf4132117", "name": "", "x": 38.664771291883746, "y": -122.46842004356215, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2695decb-d268-46b2-8604-9c33dc90518b", "name": "p1rlv17351", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f004f264-53e5-4fd1-8448-926cf4132117"}}}}, {"uuid": "21b4086a-2833-4014-96f2-2209265c8dbd", "name": "", "x": 38.66479314943949, "y": -122.4672819466205, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9d61897a-cdac-4b4a-8812-8a8692a3d958", "name": "p1rlv17403", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "21b4086a-2833-4014-96f2-2209265c8dbd"}}}}, {"uuid": "f0bd1e1c-ade2-43ea-875c-2be47a63315b", "name": "", "x": 38.661451147924325, "y": -122.47380185053476, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4903e82a-8cfb-406e-b4bf-5e01068419a3", "name": "p1rdt8174lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f0bd1e1c-ade2-43ea-875c-2be47a63315b"}}}}, {"uuid": "56156265-30ca-4fec-b4a3-d59a1ce3950c", "name": "", "x": 38.66119075710339, "y": -122.4737681067613, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f34e3e4e-bebd-4148-bcc7-cbfbecd73a2f", "name": "p1rlv17353", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "56156265-30ca-4fec-b4a3-d59a1ce3950c"}}}}, {"uuid": "8e5ea8b0-2606-496e-b62b-336950b8c3ad", "name": "", "x": 38.66166044070652, "y": -122.47400603929611, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "08709e25-b030-4801-ae00-c4879556d8b1", "name": "p1rlv17378", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8e5ea8b0-2606-496e-b62b-336950b8c3ad"}}}}, {"uuid": "20ce5bab-71b6-436d-abd2-2689fe8b4c7c", "name": "", "x": 38.66156929181106, "y": -122.47377683037024, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e1ad135-904d-47ed-ae74-32b38e1c2f88", "name": "p1rlv17383", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "20ce5bab-71b6-436d-abd2-2689fe8b4c7c"}}}}, {"uuid": "b0fbd10a-9771-4bd7-8373-783698ea0919", "name": "", "x": 38.66528062582966, "y": -122.47017186379257, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e8e03b63-853e-4cfe-bf4a-3779b2026637", "name": "p1rdt8180lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b0fbd10a-9771-4bd7-8373-783698ea0919"}}}}, {"uuid": "51433068-e7bc-4d85-ab18-651de34b6f21", "name": "", "x": 38.665280591504875, "y": -122.4701179030113, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c705333f-6f1a-4a76-a02e-eaa859e99b70", "name": "p1rlv17361", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "51433068-e7bc-4d85-ab18-651de34b6f21"}}}}, {"uuid": "689be9de-1a3d-4405-9fc9-4e242c05dec8", "name": "", "x": 38.66045657865189, "y": -122.47345917790395, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "782d6008-7fec-46b6-9461-9e33b79539d3", "name": "p1rdt8195lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "689be9de-1a3d-4405-9fc9-4e242c05dec8"}}}}, {"uuid": "cb0259a5-54e7-49a0-9eda-41e167976f9b", "name": "", "x": 38.66053224527863, "y": -122.47362350869747, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e835b413-3307-49ef-ad69-cf18a5ae7cfb", "name": "p1rlv17385", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb0259a5-54e7-49a0-9eda-41e167976f9b"}}}}, {"uuid": "1a251dab-2e8e-4c18-aeec-e3ad49945911", "name": "", "x": 38.660557365368454, "y": -122.47319806082461, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "55382019-a1a5-40fd-b90a-072af40c2258", "name": "p1rlv17387", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1a251dab-2e8e-4c18-aeec-e3ad49945911"}}}}, {"uuid": "2a87817d-94cb-4638-8c68-d8fc549cb84a", "name": "", "x": 38.66087354418496, "y": -122.47336814960953, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "169a22de-bb0a-4056-8910-151125c4ff9e", "name": "p1rlv17391", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2a87817d-94cb-4638-8c68-d8fc549cb84a"}}}}, {"uuid": "7e225669-7357-4c5f-a6b8-e6c959f1a8d3", "name": "", "x": 38.66027039448875, "y": -122.47351048965503, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "65de341c-589f-4bf9-a708-26fcc94a6c0a", "name": "p1rlv17407", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7e225669-7357-4c5f-a6b8-e6c959f1a8d3"}}}}, {"uuid": "b9619af0-f534-4ed8-b443-1108e70cd926", "name": "", "x": 38.66016282543937, "y": -122.47363770635508, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "67003f0f-6690-469e-82c0-63949ee5241e", "name": "p1rlv17417", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b9619af0-f534-4ed8-b443-1108e70cd926"}}}}, {"uuid": "1d442fee-a8d8-44b1-b273-76993ff7d240", "name": "", "x": 38.66642010101456, "y": -122.47095566992769, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "76e33e4f-05be-44d1-a503-fed82b4da974", "name": "p1rdt8201lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d442fee-a8d8-44b1-b273-76993ff7d240"}}}}, {"uuid": "fb83ab4d-1060-4dd9-9f30-4b8f22cb1510", "name": "", "x": 38.66660266134409, "y": -122.47084335519723, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ea560bcb-f930-4f42-ae45-3a60f36fdbb7", "name": "p1rlv17394", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fb83ab4d-1060-4dd9-9f30-4b8f22cb1510"}}}}, {"uuid": "48c5cddc-037d-4d5b-b65a-c400b0f007e8", "name": "", "x": 38.66627923556136, "y": -122.47106413182223, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "64a56527-23a9-4229-aa25-f6a45f2187f4", "name": "p1rlv17416", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "48c5cddc-037d-4d5b-b65a-c400b0f007e8"}}}}, {"uuid": "cb371e53-908c-4a9f-a2b4-4fac71dc0dec", "name": "", "x": 38.658114052272616, "y": -122.48189066352298, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8c1f6cd8-cde1-45cc-87ca-1355efa38077", "name": "p1rdt9055lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb371e53-908c-4a9f-a2b4-4fac71dc0dec"}}}}, {"uuid": "76473ac2-56a8-4fac-a4da-1dbaf863b311", "name": "", "x": 38.658139573766896, "y": -122.48184758396665, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be1b9922-2426-4726-9e5a-bcd33f444b57", "name": "p1rlv19616", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "76473ac2-56a8-4fac-a4da-1dbaf863b311"}}}}, {"uuid": "4dc345dd-f015-495c-886a-f88a38d01b1d", "name": "", "x": 38.65791058099435, "y": -122.46275595471984, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "afb4c195-8bb6-47d5-88f3-76adb9cda250", "name": "p1rdt9086lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4dc345dd-f015-495c-886a-f88a38d01b1d"}}}}, {"uuid": "9c47b247-8e1b-4242-9fa7-3d602fc71749", "name": "", "x": 38.657936095394604, "y": -122.46271286857773, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "19894180-0890-4585-b4e2-55500af3c41a", "name": "p1rlv19683", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9c47b247-8e1b-4242-9fa7-3d602fc71749"}}}}, {"uuid": "78134a20-f557-4c7c-bdfc-f58d76af56d2", "name": "", "x": 38.69033987948928, "y": -122.31517238474055, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "40b03cbe-470d-493a-854a-900557ac20c8", "name": "p1rdt16394lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "78134a20-f557-4c7c-bdfc-f58d76af56d2"}}}}, {"uuid": "c5989fcd-1f6f-4491-88d2-00fe769d047a", "name": "", "x": 38.690138170140635, "y": -122.31563821475763, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f827fe9e-1ffe-456c-a57b-c3374aef8ad8", "name": "p1rlv37689", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c5989fcd-1f6f-4491-88d2-00fe769d047a"}}}}, {"uuid": "f89b95b1-f645-487d-b039-3554fc023a6f", "name": "", "x": 38.69038758916915, "y": -122.3151414107498, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "da3cd593-6f05-41ba-9609-f6f1e307e998", "name": "p1rlv37691", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f89b95b1-f645-487d-b039-3554fc023a6f"}}}}, {"uuid": "c45145a7-e48a-45a9-b733-91ed9471b83f", "name": "", "x": 38.690565522935835, "y": -122.31474877047064, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "01c9efda-0adf-4932-8f54-2938964371d2", "name": "p1rlv37703", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c45145a7-e48a-45a9-b733-91ed9471b83f"}}}}, {"uuid": "065fe856-5120-4d7c-96e9-00c8304e4ee3", "name": "", "x": 38.68956634076771, "y": -122.30929268806497, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "38b0bd7c-0898-497f-bb24-4add0fd92932", "name": "p1rdt16404lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "065fe856-5120-4d7c-96e9-00c8304e4ee3"}}}}, {"uuid": "f48745c0-959b-4078-b13d-3e5d27fd30a0", "name": "", "x": 38.68932901734512, "y": -122.30982786050683, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "38bda697-2888-467e-bab0-62896a62503f", "name": "p1rlv37710", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f48745c0-959b-4078-b13d-3e5d27fd30a0"}}}}, {"uuid": "a534a629-8809-4af4-8251-f12881581d93", "name": "", "x": 38.68985442947351, "y": -122.30876497515673, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f8d998a0-628e-4009-a6c8-07af906f6d43", "name": "p1rlv37732", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a534a629-8809-4af4-8251-f12881581d93"}}}}, {"uuid": "f671dd9e-c96a-4c72-a7f2-32b8324f73df", "name": "", "x": 38.71319629081823, "y": -122.2618537891679, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "58dce206-0571-4a37-b24b-2e674e0c0d3b", "name": "p1rdm37174", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f671dd9e-c96a-4c72-a7f2-32b8324f73df"}}}}, {"uuid": "3dc216d4-8c44-41bb-a2eb-0d33315315ef", "name": "", "x": 38.713341484062944, "y": -122.26201332345111, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b24da1e-9a6e-4545-9ad4-a9f0e9675fd1", "name": "p1rlv37776", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3dc216d4-8c44-41bb-a2eb-0d33315315ef"}}}}, {"uuid": "0344c586-dfad-4b14-85d0-f6ac8106e33a", "name": "", "x": 38.71333206265715, "y": -122.26149980897426, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "23775c66-0b90-443d-8566-491405876e9d", "name": "p1rdt16424lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0344c586-dfad-4b14-85d0-f6ac8106e33a"}}}}, {"uuid": "990f60d2-63fa-4bd2-86bb-fd9b7e60eaad", "name": "", "x": 38.713372298566235, "y": -122.26118486465606, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d21a9584-0fe7-48a6-a46e-ac33e948a471", "name": "p1rdm37175", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "990f60d2-63fa-4bd2-86bb-fd9b7e60eaad"}}}}, {"uuid": "f5b8af75-ea5b-40bf-ba70-84760d41fac7", "name": "", "x": 38.71352621311042, "y": -122.26129830022444, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f5aaed5d-8312-4707-a047-634e433bf49f", "name": "p1rlv37778", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5b8af75-ea5b-40bf-ba70-84760d41fac7"}}}}, {"uuid": "72f2febe-f3c7-4987-8225-28831e04951b", "name": "", "x": 38.71269200809747, "y": -122.26236108033618, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "980376ed-54fd-434c-b58e-0bbd6eaa9954", "name": "p1rdt16427lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "72f2febe-f3c7-4987-8225-28831e04951b"}}}}, {"uuid": "16355f17-6818-4e54-8516-4c17b62d5f1e", "name": "", "x": 38.71269522836307, "y": -122.26242253360313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0d7181ee-ef64-4ded-b619-00ac09d55bf5", "name": "p1rlv37782", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "16355f17-6818-4e54-8516-4c17b62d5f1e"}}}}, {"uuid": "ba848da2-4966-44bb-878b-7dc0e31f2430", "name": "", "x": 38.684304380145115, "y": -122.31768680277943, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "26bc650a-6838-4320-8afa-b8d2f22e96e8", "name": "p1rdt16603lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ba848da2-4966-44bb-878b-7dc0e31f2430"}}}}, {"uuid": "dcfb8e68-db83-4b06-a59d-4820b9154406", "name": "", "x": 38.68458254841867, "y": -122.31796762036473, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "10be49a0-301a-4c7e-8ab7-49c14e483079", "name": "p1rlv38046", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dcfb8e68-db83-4b06-a59d-4820b9154406"}}}}, {"uuid": "bb368911-48db-4b83-b838-5c483aa7c0a3", "name": "", "x": 38.68382003837408, "y": -122.31702058531167, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0935a86b-b9fb-4058-8381-a41f67d6c9dd", "name": "p1rlv38047", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bb368911-48db-4b83-b838-5c483aa7c0a3"}}}}, {"uuid": "fd245f8b-6db6-41f1-b94c-9b6191e22523", "name": "", "x": 38.684447916688484, "y": -122.31806087736241, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9db6122d-1e51-46ac-9cea-ac436e189cd8", "name": "p1rlv38052", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fd245f8b-6db6-41f1-b94c-9b6191e22523"}}}}, {"uuid": "867a88ab-030c-47f8-8e55-ba767e4fd31c", "name": "", "x": 38.68318595308261, "y": -122.31906558684712, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d31da07-e20a-4fb8-95f4-d91450395471", "name": "p1rdt16604lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "867a88ab-030c-47f8-8e55-ba767e4fd31c"}}}}, {"uuid": "a92bf90f-f106-4803-b7cd-a94b7ec6a0e7", "name": "", "x": 38.68325558877688, "y": -122.31912993455164, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5da7ff68-5f4c-4d56-88fc-7736df03c0bf", "name": "p1rlv38048", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a92bf90f-f106-4803-b7cd-a94b7ec6a0e7"}}}}, {"uuid": "1be34c71-cd62-4229-a445-4640d75a7920", "name": "", "x": 38.683074628268045, "y": -122.31900518071453, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cafc6c03-240d-499d-a3d8-983b554dd007", "name": "p1rlv38050", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1be34c71-cd62-4229-a445-4640d75a7920"}}}}, {"uuid": "85f3f994-ebf6-4123-8306-7c66f4fe90fe", "name": "", "x": 38.72488522966494, "y": -122.31175617505791, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a4a3b828-bddf-4314-b9a5-03b9dfcd2618", "name": "p1rdt16787lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "85f3f994-ebf6-4123-8306-7c66f4fe90fe"}}}}, {"uuid": "4cb84e15-fc68-4ec5-ab40-cf063445d1c9", "name": "", "x": 38.72480906566549, "y": -122.31154585900022, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a25b3511-86cf-404e-944f-273d3f94c05a", "name": "p1rlv38414", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4cb84e15-fc68-4ec5-ab40-cf063445d1c9"}}}}, {"uuid": "a1e6aa75-b873-4007-a204-cf87e0d543ff", "name": "", "x": 38.724919569400605, "y": -122.3119474333546, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a6e4595c-0ad9-4501-b86f-c559917d4b86", "name": "p1rlv38419", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a1e6aa75-b873-4007-a204-cf87e0d543ff"}}}}, {"uuid": "37841bc9-c1dc-4418-bcb3-7309b15e549c", "name": "", "x": 38.725467899287466, "y": -122.31258369528427, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9c261090-bc22-4d81-9a9e-75227cd7c99e", "name": "p1rdt16790lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "37841bc9-c1dc-4418-bcb3-7309b15e549c"}}}}, {"uuid": "788ddba8-11aa-4aa0-8e92-f9c2adc10b3d", "name": "", "x": 38.725441863299416, "y": -122.312541080781, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "201112bb-3dc7-4a15-9af6-155626ac1ae5", "name": "p1rlv38417", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "788ddba8-11aa-4aa0-8e92-f9c2adc10b3d"}}}}, {"uuid": "5793a67e-5c04-4b95-ba75-d4fe24c7dea9", "name": "", "x": 38.69566612075781, "y": -122.29850531296424, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e1abef1d-4ffc-4696-91ca-e81ac36cce61", "name": "p1rdt16847lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5793a67e-5c04-4b95-ba75-d4fe24c7dea9"}}}}, {"uuid": "a380a296-2b02-4d46-bfde-f814f84ed80a", "name": "", "x": 38.695297864066646, "y": -122.29823690772227, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a0764c32-4f46-473a-9a72-cccc45ae28d7", "name": "p1rlv38535", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a380a296-2b02-4d46-bfde-f814f84ed80a"}}}}, {"uuid": "14b0b62d-7296-422d-9cc1-708bd7167a8c", "name": "", "x": 38.69607606503067, "y": -122.29876976693473, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5ff930f9-63f0-4cab-b74a-3db7eb99f9eb", "name": "p1rlv38536", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "14b0b62d-7296-422d-9cc1-708bd7167a8c"}}}}, {"uuid": "4d757316-db89-48f9-b906-07965b862b6a", "name": "", "x": 38.74356263285725, "y": -122.27336627842594, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0df1550a-7e69-42e9-8059-3a36ecb3d253", "name": "p1rdt16911lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d757316-db89-48f9-b906-07965b862b6a"}}}}, {"uuid": "28b52fe4-3ee2-48fe-9797-05cbf31832d3", "name": "", "x": 38.74357721508068, "y": -122.27335107450713, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4a3851f7-2dd3-447b-918f-7a8c954f21d1", "name": "p1rlv38638", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "28b52fe4-3ee2-48fe-9797-05cbf31832d3"}}}}, {"uuid": "752654c3-b2fa-4808-8238-2c2cfff7aadc", "name": "", "x": 38.67909765473299, "y": -122.51997053087246, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d49257c8-f8eb-4024-9c02-461d18cdd3d5", "name": "p1rdt383", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "752654c3-b2fa-4808-8238-2c2cfff7aadc"}}}}, {"uuid": "46aeb7f3-d13e-4a01-8839-fdd865ccf46d", "name": "", "x": 38.67949973700607, "y": -122.52574842403467, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8d8cd980-268f-4adb-a6ee-70edf7784542", "name": "p1rdt383-p1rdt384x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "46aeb7f3-d13e-4a01-8839-fdd865ccf46d"}}}}, {"uuid": "a23443c6-1d62-4ffa-9f5b-5736dfcce6aa", "name": "", "x": 38.6790657111712, "y": -122.52914676125815, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7adf2f4b-f0fd-4c53-abcf-d90fe1a2b4c4", "name": "p1rdt384", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a23443c6-1d62-4ffa-9f5b-5736dfcce6aa"}}}}, {"uuid": "90950951-2a50-4431-b77b-57d9b3dbe8c7", "name": "", "x": 38.651801942472055, "y": -122.5073324871614, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f9240d01-bf5d-41ed-8c53-c1f04af1a236", "name": "p1rdt383-p1rdt7300x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "90950951-2a50-4431-b77b-57d9b3dbe8c7"}}}}, {"uuid": "4d44044a-2d92-4b3c-9aab-774930b93609", "name": "", "x": 38.65515241674437, "y": -122.50889970027711, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e5ac1506-77e9-4b90-ad3d-18be099063a9", "name": "p1rdt383-p1rdt7300x_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d44044a-2d92-4b3c-9aab-774930b93609"}}}}, {"uuid": "05fc9700-79a2-4dc4-bf3d-f5de2a903094", "name": "", "x": 38.653733535353965, "y": -122.50089156658129, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d065da7b-7e88-4e63-a47c-959f4d4c6e1c", "name": "p1rdt7299", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "05fc9700-79a2-4dc4-bf3d-f5de2a903094"}}}}, {"uuid": "c914feb5-e9de-422b-aeaf-cfc62dd17293", "name": "", "x": 38.65375040418197, "y": -122.49983768034305, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6322bf4d-0976-4bae-94c0-f76f83ccb9bf", "name": "p1rdt7316", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c914feb5-e9de-422b-aeaf-cfc62dd17293"}}}}, {"uuid": "ab222d15-220f-49d0-9978-7493ba856d51", "name": "", "x": 38.65383842524826, "y": -122.5014575190295, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b468be25-1324-46ab-9424-887741ca1134", "name": "p1rdt7321", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ab222d15-220f-49d0-9978-7493ba856d51"}}}}, {"uuid": "9819f669-9c19-41ec-86fe-e3a06b9a4003", "name": "", "x": 38.65408052954152, "y": -122.50195797033598, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d2e605b4-fe7a-4571-947d-8ae19de627d8", "name": "p1rdt7308", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9819f669-9c19-41ec-86fe-e3a06b9a4003"}}}}, {"uuid": "dd3454db-2254-4e87-a37a-95cfce8f56ef", "name": "", "x": 38.65442560903119, "y": -122.50257618415456, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a955da2d-e212-4026-b1fb-0021a04ded07", "name": "p1rdt7294", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dd3454db-2254-4e87-a37a-95cfce8f56ef"}}}}, {"uuid": "27154954-bf7a-47cd-b84f-cfe43e152146", "name": "", "x": 38.652479455643565, "y": -122.5026700890289, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e6f24e3a-088a-4d1b-8292-03015289d88e", "name": "p1rdt7303", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "27154954-bf7a-47cd-b84f-cfe43e152146"}}}}, {"uuid": "ac160d78-43c2-4240-98f5-e6ae472758ac", "name": "", "x": 38.652370317308936, "y": -122.50523190353242, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48efebbb-c70a-47d3-aae3-0e39088fc455", "name": "p1rdt7317", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ac160d78-43c2-4240-98f5-e6ae472758ac"}}}}, {"uuid": "03e38011-c0fb-4e11-9933-4cd3cac852ba", "name": "", "x": 38.65220758039855, "y": -122.50510436245315, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e9980c6-3edc-4b4a-be98-cec731419c30", "name": "p1rdt7303-p1rdt7317x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "03e38011-c0fb-4e11-9933-4cd3cac852ba"}}}}, {"uuid": "5860e8c6-343d-4d04-bad2-41ef009e292b", "name": "", "x": 38.65176065727734, "y": -122.50732046975546, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "05f14a3e-053e-4b65-b962-da7804b9e2c1", "name": "p1rdt7300", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5860e8c6-343d-4d04-bad2-41ef009e292b"}}}}, {"uuid": "07ba29a5-2151-46cd-a5ab-f359ec3ab19c", "name": "", "x": 38.64755417890137, "y": -122.50920989641365, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "47f8ed28-4bff-47d9-8ffe-4509e9c5b7fc", "name": "p1rdt6488-p1rdt7300x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "07ba29a5-2151-46cd-a5ab-f359ec3ab19c"}}}}, {"uuid": "2f8c22fe-e901-48d9-9eef-46f361d4dc9c", "name": "", "x": 38.64759956755727, "y": -122.50867546400877, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b96c1e20-68ac-4548-a068-86483c7fa921", "name": "p1rdt6488-p1rdt7300xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2f8c22fe-e901-48d9-9eef-46f361d4dc9c"}}}}, {"uuid": "0840458c-3040-4065-b329-753f2e9edfff", "name": "", "x": 38.659282749601154, "y": -122.47232465037078, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bee93ff6-6ff8-4572-b339-c8e897dac81b", "name": "p1rdt7795", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0840458c-3040-4065-b329-753f2e9edfff"}}}}, {"uuid": "218dc36b-329c-4f26-a80d-dc68a2c4a6cc", "name": "", "x": 38.65789678232331, "y": -122.46280701212554, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "75ee3b24-7407-45ba-94d5-abe187306f13", "name": "p1rdt9086", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "218dc36b-329c-4f26-a80d-dc68a2c4a6cc"}}}}, {"uuid": "ead0976b-5a32-4ecb-90c0-3f17d38fc9bf", "name": "", "x": 38.6582588467901, "y": -122.47506760778616, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0cd22d3e-1e2a-4a99-9967-b9df95837915", "name": "p1rdt7757-p1rdt7795x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ead0976b-5a32-4ecb-90c0-3f17d38fc9bf"}}}}, {"uuid": "575a3212-4155-4852-a5f4-bb331a4bbb26", "name": "", "x": 38.66713136194248, "y": -122.47883578171474, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "53e5fee4-5a31-448e-8bd0-d8996468d085", "name": "p1rdt6261", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "575a3212-4155-4852-a5f4-bb331a4bbb26"}}}}, {"uuid": "c526aa31-5e92-4d33-af90-0c67bd587449", "name": "", "x": 38.66662516142702, "y": -122.47987793918193, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6c00c7b1-0aec-4669-9679-cbc1476e0526", "name": "p1rdt6261-p1rdt6262x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c526aa31-5e92-4d33-af90-0c67bd587449"}}}}, {"uuid": "8d4d5410-3d6d-4a36-8d81-2eb1e14929e8", "name": "", "x": 38.66651499085745, "y": -122.4800586749112, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf092ec9-ecda-4216-9ac0-0bc035973515", "name": "p1rdt6262", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8d4d5410-3d6d-4a36-8d81-2eb1e14929e8"}}}}, {"uuid": "4c9a6417-dd7e-4201-97f3-4b1de459f448", "name": "", "x": 38.666918119613086, "y": -122.48091258305858, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c61df077-693e-4e67-aea6-ee60b99406d1", "name": "p1rdt6263", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4c9a6417-dd7e-4201-97f3-4b1de459f448"}}}}, {"uuid": "7ca3f583-3b6e-4756-99c2-2beee9dd510f", "name": "", "x": 38.66244739498498, "y": -122.4766461808176, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e22d08f0-2afc-426a-a0c0-6b00cc1103aa", "name": "p1rdt6266", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7ca3f583-3b6e-4756-99c2-2beee9dd510f"}}}}, {"uuid": "dfcbece4-24cf-4df0-b723-98cebf605a35", "name": "", "x": 38.663631853304395, "y": -122.47754329911722, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cab917a3-5cc2-46d5-9cee-971591841f12", "name": "p1rdt6261-p1rdt6266x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dfcbece4-24cf-4df0-b723-98cebf605a35"}}}}, {"uuid": "d4d80403-25d9-41a5-9e44-5bc2e1041169", "name": "", "x": 38.66255554922429, "y": -122.47735618000138, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4a03d20d-664a-4e80-abec-a36910787829", "name": "p1rdt6264", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d4d80403-25d9-41a5-9e44-5bc2e1041169"}}}}, {"uuid": "7f90f9c9-ada7-4545-805f-74e7ff76cce2", "name": "", "x": 38.66324435870563, "y": -122.47754611470971, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9b6508ce-e51b-4173-8b54-3f3eb7a2cd71", "name": "p1rdt6266-p1rdt6267x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7f90f9c9-ada7-4545-805f-74e7ff76cce2"}}}}, {"uuid": "edabaa6d-c4da-4492-a840-5b6a75d9064f", "name": "", "x": 38.66526274271137, "y": -122.47948778772573, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a1d9cfa7-0024-4896-a263-2715086f2ad6", "name": "p1rdt6267", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "edabaa6d-c4da-4492-a840-5b6a75d9064f"}}}}, {"uuid": "3d879b6c-dee9-4e19-a2b9-c9353631ef11", "name": "", "x": 38.66146360124312, "y": -122.4739001517938, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d07105ef-1ba3-4775-aeb4-650b5ea8736e", "name": "p1rdt6266-p1rdt8174x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3d879b6c-dee9-4e19-a2b9-c9353631ef11"}}}}, {"uuid": "fa6491bf-299d-44eb-ad2d-891e877aa105", "name": "", "x": 38.75306841044715, "y": -122.36663378364803, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "79d0fee6-369b-4f95-a2d2-cd05232652e3", "name": "p1rdt181", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa6491bf-299d-44eb-ad2d-891e877aa105"}}}}, {"uuid": "c072f967-5c31-42c3-8e9b-35184b126f3f", "name": "", "x": 38.754868310420626, "y": -122.36837472635783, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "24681ab1-3904-4509-85e6-d9bb1dba4c8e", "name": "p1rdt181_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c072f967-5c31-42c3-8e9b-35184b126f3f"}}}}, {"uuid": "2ad22731-6846-4b63-baa9-765766802509", "name": "", "x": 38.771927561946114, "y": -122.36440291040475, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0d4e6a87-0313-419f-8feb-7ea3a29f59ae", "name": "p1rdt275", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2ad22731-6846-4b63-baa9-765766802509"}}}}, {"uuid": "665fada7-7a88-4136-9eab-40f5c884f0b2", "name": "", "x": 38.78773053668457, "y": -122.34702184190017, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1a85646-be2b-4b15-9c2f-cc603c7e06df", "name": "p1rdt253", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "665fada7-7a88-4136-9eab-40f5c884f0b2"}}}}, {"uuid": "b4b135e0-c9a9-4999-9448-44a19e6f2767", "name": "", "x": 38.76715093535089, "y": -122.36057334237034, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eb9e5f0f-8bcf-4019-a786-3f24334e9ae7", "name": "p1rdt68", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b4b135e0-c9a9-4999-9448-44a19e6f2767"}}}}, {"uuid": "32e939e4-5261-4ed7-9bef-2dc70b0e4447", "name": "", "x": 38.77038045634796, "y": -122.36232121374398, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8435bee2-05ea-4208-9520-809129624d70", "name": "p1rdt275-p1rdt68x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "32e939e4-5261-4ed7-9bef-2dc70b0e4447"}}}}, {"uuid": "54cceeea-9aa0-4d66-8115-b4b848862660", "name": "", "x": 38.762804233208215, "y": -122.3567217728313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e9cb7919-b8bd-46c1-a173-90a5d241c46e", "name": "p1rdt280", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "54cceeea-9aa0-4d66-8115-b4b848862660"}}}}, {"uuid": "8845fc18-33d7-47e8-a26b-2bf3b16d7ee2", "name": "", "x": 38.754224477281774, "y": -122.36483177825646, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ac745c6f-6e78-4a68-affa-649f91d3aa7c", "name": "p1rdt281", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8845fc18-33d7-47e8-a26b-2bf3b16d7ee2"}}}}, {"uuid": "cd2affdb-33a9-4f80-bda0-c84fa9ffaa09", "name": "", "x": 38.762332092473166, "y": -122.35720189679247, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4425707e-f2b0-419f-828e-a4642ee34b5a", "name": "p1rdt280-p1rdt281x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cd2affdb-33a9-4f80-bda0-c84fa9ffaa09"}}}}, {"uuid": "d1a7b63c-63eb-4950-aaa9-c61ee1ba140b", "name": "", "x": 38.72318515388558, "y": -122.41088395202819, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2fddf29e-6eef-4c60-ad8b-4580440973b3", "name": "p1rdt181-p1rdt297x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1a7b63c-63eb-4950-aaa9-c61ee1ba140b"}}}}, {"uuid": "851a2f84-14c6-409d-8071-4667378696d9", "name": "", "x": 38.726937156537616, "y": -122.40539968889463, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d87f56c0-0a3f-4a94-8f60-1ece461290d0", "name": "p1rdt181-p1rdt297x_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "851a2f84-14c6-409d-8071-4667378696d9"}}}}, {"uuid": "759e1907-5ba4-48d6-919d-b558f46832b1", "name": "", "x": 38.759945311222936, "y": -122.44222861124264, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "170a2bcb-d7ce-4617-855b-9111b84262ed", "name": "p1rdt3776", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "759e1907-5ba4-48d6-919d-b558f46832b1"}}}}, {"uuid": "7668d332-5379-4200-a145-37c5d95aa7ac", "name": "", "x": 38.75895331123435, "y": -122.44467277060775, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5f9af980-79c4-4daf-b8fc-44e02953f98b", "name": "p1rdt3777", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7668d332-5379-4200-a145-37c5d95aa7ac"}}}}, {"uuid": "02b963dd-7858-4cea-b384-6910759c8ab5", "name": "", "x": 38.7505314706947, "y": -122.41545810153862, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7eca59ac-01f1-40d7-a0ec-51f355285e01", "name": "p1rdt270", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "02b963dd-7858-4cea-b384-6910759c8ab5"}}}}, {"uuid": "0006edd5-9a24-4cdf-8952-aeacecc849f2", "name": "", "x": 38.75941275867633, "y": -122.44145409385084, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6168ebbc-8fd5-49a0-94db-887814eceaba", "name": "p1rdt270-p1rdt3776x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0006edd5-9a24-4cdf-8952-aeacecc849f2"}}}}, {"uuid": "27c267c2-ebc5-4f52-93a6-6ee6fa420984", "name": "", "x": 38.724404971590296, "y": -122.41244167570912, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e2c76250-d7ea-4da4-8008-dac1a579e974", "name": "p1rdt270-p1rdt298x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "27c267c2-ebc5-4f52-93a6-6ee6fa420984"}}}}, {"uuid": "b13b2b3e-f03d-40da-ab3d-d9146809b14f", "name": "", "x": 38.72936375125469, "y": -122.41301863676793, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ac7c613f-190c-493e-8e89-3ef48e8efdb9", "name": "p1rdt270-p1rdt298x_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b13b2b3e-f03d-40da-ab3d-d9146809b14f"}}}}, {"uuid": "f23ba844-eefe-4850-91bd-642274b7cd43", "name": "", "x": 38.72321115431449, "y": -122.41092660136522, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d32493ec-06be-48ef-959e-779c79c507a3", "name": "p1rdt297", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f23ba844-eefe-4850-91bd-642274b7cd43"}}}}, {"uuid": "f64c9648-faca-44e7-8a97-9c3c8dc95507", "name": "", "x": 38.72444619013448, "y": -122.4124539994752, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7a468f13-c61f-4c01-aa27-c75fb02030e0", "name": "p1rdt298", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f64c9648-faca-44e7-8a97-9c3c8dc95507"}}}}, {"uuid": "546b8fad-55ef-4415-a10c-2b3d67c1758c", "name": "", "x": 38.716932571899626, "y": -122.4194260124673, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "91f76b91-e00a-4a88-8ee8-ec403c2c7d96", "name": "p1rdt385", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "546b8fad-55ef-4415-a10c-2b3d67c1758c"}}}}, {"uuid": "5c83ea19-2401-4a56-b711-6b8cc4186995", "name": "", "x": 38.70723340886135, "y": -122.42474689668317, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "22179eaa-fd19-4619-8b31-52bcb36ec683", "name": "p1rdt252-p1rdt385x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5c83ea19-2401-4a56-b711-6b8cc4186995"}}}}, {"uuid": "215d5350-57f3-47a2-ad91-9221da3b8bdc", "name": "", "x": 38.7068487847659, "y": -122.42495904757907, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f9c899bc-796a-4e92-88db-6aa11f8777cb", "name": "p1rdt251-p1rdt254x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "215d5350-57f3-47a2-ad91-9221da3b8bdc"}}}}, {"uuid": "ef1d5226-a8f9-4454-a993-7cb000b03794", "name": "", "x": 38.706847489569306, "y": -122.42594987463313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ab802e3-3a0a-413c-8865-e3b3d08e44a8", "name": "p1rdt254", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef1d5226-a8f9-4454-a993-7cb000b03794"}}}}, {"uuid": "3c286a77-6cc8-436e-9fc7-c2d3036ddaba", "name": "", "x": 38.69595800578408, "y": -122.39252013725728, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8e28087b-b80e-4043-b0f0-0bc82c91f5e8", "name": "p1rdt258", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3c286a77-6cc8-436e-9fc7-c2d3036ddaba"}}}}, {"uuid": "804b2239-d5e8-48c0-9827-b37ecf5b0754", "name": "", "x": 38.697506302675386, "y": -122.39110055463347, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf660777-f77e-4d9b-afff-73a84274c270", "name": "p1rdt262", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "804b2239-d5e8-48c0-9827-b37ecf5b0754"}}}}, {"uuid": "c54df0ed-ada6-4bb9-a22a-77c5b1643b95", "name": "", "x": 38.6960521884224, "y": -122.39265347986003, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "209cebda-044a-42a3-b2f0-fe5b76b80643", "name": "p1rdt261", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c54df0ed-ada6-4bb9-a22a-77c5b1643b95"}}}}, {"uuid": "c2026069-787d-446d-98d6-de87e2aceec7", "name": "", "x": 38.696015106037905, "y": -122.39255812819005, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "be0fa139-8da7-4cba-9e49-faf4a4814035", "name": "p1rdt258-p1rdt261x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c2026069-787d-446d-98d6-de87e2aceec7"}}}}, {"uuid": "4caf55e0-0b8c-407e-811a-83af58390919", "name": "", "x": 38.69712125423101, "y": -122.39909419849987, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bbe3ac37-aca0-47fd-ac5d-be390cad10ab", "name": "p1rdt261-p1rdt277x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4caf55e0-0b8c-407e-811a-83af58390919"}}}}, {"uuid": "4f2e309d-192c-4ca8-a1de-e92bdeb74d0c", "name": "", "x": 38.702132662964175, "y": -122.38784923319449, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a2b529c9-4695-42f3-a0e3-69bbb34ff285", "name": "p1rdt37-p1rdt80x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4f2e309d-192c-4ca8-a1de-e92bdeb74d0c"}}}}, {"uuid": "81d8b59a-049e-4f0c-be85-a34d084e4b44", "name": "", "x": 38.70165469665771, "y": -122.38758437608678, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9dcbfdc3-b597-4e9e-a86f-4d0ff396ba70", "name": "p1rdt37", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "81d8b59a-049e-4f0c-be85-a34d084e4b44"}}}}, {"uuid": "8f6e7c1a-1fd0-4353-ae0c-01e914a08470", "name": "", "x": 38.70226336170039, "y": -122.37889294477628, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a9c4411-f402-464c-ad25-d439b87ef768", "name": "p1rdt34", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8f6e7c1a-1fd0-4353-ae0c-01e914a08470"}}}}, {"uuid": "df30e6d5-4f96-4c9e-822f-7dc4d01fc1c6", "name": "", "x": 38.70240564817688, "y": -122.37853520540186, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "31b06630-2aae-4fe7-9e31-f911c91121cd", "name": "p1rdt77", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "df30e6d5-4f96-4c9e-822f-7dc4d01fc1c6"}}}}, {"uuid": "07e40688-ddb5-443c-82d8-7dfb1870c9b0", "name": "", "x": 38.70192539724856, "y": -122.37910641908904, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b45513a3-8e88-45e9-99d3-6d244c90c256", "name": "p1rdt38", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "07e40688-ddb5-443c-82d8-7dfb1870c9b0"}}}}, {"uuid": "26fcf062-38f3-4fc4-944a-64a938b61bab", "name": "", "x": 38.70129185446362, "y": -122.37973917584448, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "668d32be-c07a-4387-86a5-e9754af11e9c", "name": "p1rdt31-p1rdt38x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "26fcf062-38f3-4fc4-944a-64a938b61bab"}}}}, {"uuid": "ed47d79a-4bc3-482c-a4a9-cbd1e0f3ff3d", "name": "", "x": 38.701554940346995, "y": -122.37742353030349, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2b82a9a2-b1d1-44eb-a451-946643ef613d", "name": "p1rdt74-p1rdt85x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ed47d79a-4bc3-482c-a4a9-cbd1e0f3ff3d"}}}}, {"uuid": "eea93f53-2784-47ad-9645-52baa3baf1fb", "name": "", "x": 38.702210844779025, "y": -122.37749036925975, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b884fef-8b8f-4ed5-9033-b8177d1c7d70", "name": "p1rdt74", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eea93f53-2784-47ad-9645-52baa3baf1fb"}}}}, {"uuid": "147c7c3d-719e-47e9-9fbe-5d5d89ded094", "name": "", "x": 38.69878213406897, "y": -122.37500166002606, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf205ba7-ac66-4318-aeca-c75eb96cbd1e", "name": "p1rdt456", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "147c7c3d-719e-47e9-9fbe-5d5d89ded094"}}}}, {"uuid": "16e64a55-a47c-4563-9842-a45162327cac", "name": "", "x": 38.698844229551156, "y": -122.37481712432647, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cee642e7-12f0-4746-841e-d8cda6fff57e", "name": "p1rdt489", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "16e64a55-a47c-4563-9842-a45162327cac"}}}}, {"uuid": "2156d576-a0de-4c7f-8b6b-83a2796d5de4", "name": "", "x": 38.698450220223094, "y": -122.375819293565, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b092ee09-4c5e-46b5-8ec2-51f99254c220", "name": "p1rdt456-p1rdt465x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2156d576-a0de-4c7f-8b6b-83a2796d5de4"}}}}, {"uuid": "154ca468-f940-41a0-813f-c7a6390c0c78", "name": "", "x": 38.693782143657465, "y": -122.37465775612712, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "05082892-d69e-4c8f-ba19-c2a627e1c345", "name": "p1rdt46", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "154ca468-f940-41a0-813f-c7a6390c0c78"}}}}, {"uuid": "c6b93af1-6cb1-4ff7-847d-a8f8e24da09c", "name": "", "x": 38.69314320252447, "y": -122.37482430214054, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "50f3b5f3-3fb5-4fb9-b2e6-b37200af0901", "name": "p1rdt70", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c6b93af1-6cb1-4ff7-847d-a8f8e24da09c"}}}}, {"uuid": "c1697cd7-1b88-45cc-b5f6-415d8eb7a1bc", "name": "", "x": 38.69495141442872, "y": -122.3748625110079, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b61caefd-d5aa-4019-9ac0-aaf8cedc71d0", "name": "p1rdt458", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c1697cd7-1b88-45cc-b5f6-415d8eb7a1bc"}}}}, {"uuid": "886222cb-cab4-4cd2-836a-660c88e16dfa", "name": "", "x": 38.69185315698694, "y": -122.37350964662168, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2faff95d-f394-427a-9d62-75224f830c9e", "name": "p1rdt72", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "886222cb-cab4-4cd2-836a-660c88e16dfa"}}}}, {"uuid": "0ee4f148-fd6a-46ed-ad40-dd2c07a2bdea", "name": "", "x": 38.69169101529133, "y": -122.37352255937813, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a6fb1323-f697-4423-a70d-838056200402", "name": "p1rdt52", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0ee4f148-fd6a-46ed-ad40-dd2c07a2bdea"}}}}, {"uuid": "ec8d68dd-493a-4fc5-92b6-8771c3237b37", "name": "", "x": 38.693098193510316, "y": -122.37377475782415, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "137c345c-77cc-4324-bc0e-e0ba896a5f43", "name": "p1rdt49", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ec8d68dd-493a-4fc5-92b6-8771c3237b37"}}}}, {"uuid": "0990a9d9-e9d3-40e6-8e79-7a8bd3f851c3", "name": "", "x": 38.694135169317704, "y": -122.37389220491741, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1d8f5898-7d36-4e40-9980-76d11ef18adb", "name": "p1rdt56", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0990a9d9-e9d3-40e6-8e79-7a8bd3f851c3"}}}}, {"uuid": "560d2c90-f0c1-4f09-b2ab-5bdb242b8f86", "name": "", "x": 38.69445247244586, "y": -122.37424590782481, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6fa14b51-a977-4e40-8f9c-28249e576fcf", "name": "p1rdt472", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "560d2c90-f0c1-4f09-b2ab-5bdb242b8f86"}}}}, {"uuid": "5dc257f9-663e-496e-82ab-f02badf92781", "name": "", "x": 38.695584690016524, "y": -122.37575707999054, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "04fc215c-7f3e-45e1-a49c-727b0fcdae93", "name": "p1rdt458-p1rdt468x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5dc257f9-663e-496e-82ab-f02badf92781"}}}}, {"uuid": "c0ce7def-bf8a-4994-9211-1090a6708213", "name": "", "x": 38.69312267817216, "y": -122.37604335226409, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0c5d8237-0351-4eb2-83e6-13975b37bfa7", "name": "p1rdt50", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c0ce7def-bf8a-4994-9211-1090a6708213"}}}}, {"uuid": "a6e05e13-c59b-487a-a856-c53af892ec53", "name": "", "x": 38.69253761865749, "y": -122.37617492032506, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e7305e2b-0a48-4630-8b8e-c3819f1c9cd1", "name": "p1rdt53", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a6e05e13-c59b-487a-a856-c53af892ec53"}}}}, {"uuid": "d0d9e0b2-5201-4618-9538-651dea7a923c", "name": "", "x": 38.69357324297057, "y": -122.37603943809668, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4ea7e0bb-bdc5-429a-8889-2f12c94db72e", "name": "p1rdt59", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d0d9e0b2-5201-4618-9538-651dea7a923c"}}}}, {"uuid": "e2fdec26-5a5b-48a2-a148-888c835ac073", "name": "", "x": 38.69405568995833, "y": -122.37588221381021, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "577124ac-ea2b-4a60-be47-14b0f5db305e", "name": "p1rdt40", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e2fdec26-5a5b-48a2-a148-888c835ac073"}}}}, {"uuid": "49b5489f-b73f-492f-be37-43f9823f28f6", "name": "", "x": 38.69445481567878, "y": -122.37574430437743, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "12fef7fc-57f0-4494-becd-4724b84dbbcb", "name": "p1rdt457", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "49b5489f-b73f-492f-be37-43f9823f28f6"}}}}, {"uuid": "d2981dd6-bb67-4a21-b888-fa072ef2814d", "name": "", "x": 38.69524468972365, "y": -122.37577988845278, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d709af4b-1115-403b-a68d-76c63c93adf2", "name": "p1rdt474", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d2981dd6-bb67-4a21-b888-fa072ef2814d"}}}}, {"uuid": "036ca743-6e5f-4397-b298-e6da7abbbd82", "name": "", "x": 38.695656536068775, "y": -122.3757951768077, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5814195b-dd60-4a1e-9af6-b9b84fa4c0c7", "name": "p1rdt468-p1rdt474x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "036ca743-6e5f-4397-b298-e6da7abbbd82"}}}}, {"uuid": "7de12271-b8bc-4949-9775-db2f3d0fa8b9", "name": "", "x": 38.69416819650434, "y": -122.37332846825741, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f9397c58-45a1-4ec3-bd84-b4cd5b52dc80", "name": "p1rdt65", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7de12271-b8bc-4949-9775-db2f3d0fa8b9"}}}}, {"uuid": "f574c707-7785-4ef9-9cf6-4f890606558b", "name": "", "x": 38.69364252102314, "y": -122.37276961025155, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ab2b6727-4d87-4b00-bd49-ba7a6b1b9ce6", "name": "p1rdt63", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f574c707-7785-4ef9-9cf6-4f890606558b"}}}}, {"uuid": "ddcf1e4b-2864-4c58-9602-0c22fa480875", "name": "", "x": 38.69429429294349, "y": -122.37331586905341, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4ae86125-88c3-44fb-9fe9-1a5d820606f6", "name": "p1rdt467", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ddcf1e4b-2864-4c58-9602-0c22fa480875"}}}}, {"uuid": "df901f95-bfa5-4f1a-be8d-56be09dc1b3a", "name": "", "x": 38.69469140583874, "y": -122.37342739439052, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "48179f57-b0b9-491b-b654-81583768923a", "name": "p1rdt469", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "df901f95-bfa5-4f1a-be8d-56be09dc1b3a"}}}}, {"uuid": "956e346e-1e34-4cec-b6f1-259a87f18ad5", "name": "", "x": 38.69542702599285, "y": -122.37386149152691, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a634585d-0c70-428e-a3b2-1ec4717d7878", "name": "p1rdt464", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "956e346e-1e34-4cec-b6f1-259a87f18ad5"}}}}, {"uuid": "09d2e6ee-2f60-4e01-83a5-962fd176bb64", "name": "", "x": 38.69557377117983, "y": -122.37396893690091, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2e5c3d02-1cd2-45e4-90d3-10b135c65f13", "name": "p1rdt480", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "09d2e6ee-2f60-4e01-83a5-962fd176bb64"}}}}, {"uuid": "5a7937d8-a3eb-45f2-b178-6c3eead7e7cc", "name": "", "x": 38.69642974090264, "y": -122.37431272204606, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "76880999-6f79-4fc6-9367-1c419eee26d5", "name": "p1rdt473", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5a7937d8-a3eb-45f2-b178-6c3eead7e7cc"}}}}, {"uuid": "fea57a38-f4cb-464a-aeee-8c88416598f1", "name": "", "x": 38.69676892757635, "y": -122.37432921866969, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d1bb6f93-7aed-47d7-99db-7c17352a42b8", "name": "p1rdt453", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fea57a38-f4cb-464a-aeee-8c88416598f1"}}}}, {"uuid": "7de38676-e68c-41bd-b881-6545360d00a9", "name": "", "x": 38.697042200822686, "y": -122.37424988896967, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d51e6f65-c45c-4f10-a17f-6ef684a0a06c", "name": "p1rdt452", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7de38676-e68c-41bd-b881-6545360d00a9"}}}}, {"uuid": "d1220ca0-5321-4d82-a08a-3738153e2860", "name": "", "x": 38.69788387901549, "y": -122.3749210284041, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b20fa59a-8573-461a-9c4a-0d47e40d2601", "name": "p1rdt466", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d1220ca0-5321-4d82-a08a-3738153e2860"}}}}, {"uuid": "c75db6cf-545e-48dc-8ac1-330cef2f7643", "name": "", "x": 38.69827011722288, "y": -122.37584385822461, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "64ba6716-89f9-49a4-9793-ba80ae41bcd0", "name": "p1rdt466-p1rdt478x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c75db6cf-545e-48dc-8ac1-330cef2f7643"}}}}, {"uuid": "715de1e8-65e3-4ad3-9996-d73649cb2471", "name": "", "x": 38.701722794560474, "y": -122.37384904824599, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "12d5c579-0570-44db-a751-8eeb92355af9", "name": "p1rdt459", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "715de1e8-65e3-4ad3-9996-d73649cb2471"}}}}, {"uuid": "a4a0e6c6-1a05-444c-8d95-22a456abb8b6", "name": "", "x": 38.701153728978355, "y": -122.37360100904912, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eed7e6a8-2b4a-4a54-b69a-e3e1a0614213", "name": "p1rdt471", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a4a0e6c6-1a05-444c-8d95-22a456abb8b6"}}}}, {"uuid": "9c8b7067-51d1-4537-b1ae-3e54b168100a", "name": "", "x": 38.702243046289325, "y": -122.3733960017453, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fcfdc5bf-1c87-42e2-8b35-1f7125d3b5ed", "name": "p1rdt462", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9c8b7067-51d1-4537-b1ae-3e54b168100a"}}}}, {"uuid": "f13eb1dc-c712-49aa-af69-41037bc6049a", "name": "", "x": 38.702902444369066, "y": -122.37348707489292, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dfb0d992-ab18-4f73-933e-a01ce73ef3b2", "name": "p1rdt487", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f13eb1dc-c712-49aa-af69-41037bc6049a"}}}}, {"uuid": "76e35c9a-9560-4eeb-8df3-09560a9c278e", "name": "", "x": 38.72548231736972, "y": -122.31263452007998, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4774ed1a-85ec-4ca0-8e9a-3b232588fb0c", "name": "p1rdt16790", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "76e35c9a-9560-4eeb-8df3-09560a9c278e"}}}}, {"uuid": "0265a43f-a1e0-4db0-b8c6-5963dd5ac674", "name": "", "x": 38.7248434734621, "y": -122.31174862017714, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d4bc644c-9875-4846-8b0f-dfa0568de623", "name": "p1rdt16787", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0265a43f-a1e0-4db0-b8c6-5963dd5ac674"}}}}, {"uuid": "20c89e0d-0eeb-4562-be97-b9842e309720", "name": "", "x": 38.741935598212194, "y": -122.27647050486847, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d29266e8-ce67-45bf-93d9-710d4684ce0b", "name": "p1rdt16790-p1rdt16911x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "20c89e0d-0eeb-4562-be97-b9842e309720"}}}}, {"uuid": "7e5d3205-621f-494a-ab6d-fad769918f9e", "name": "", "x": 38.743604391211804, "y": -122.2733738127215, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "725fbd98-74ba-4143-8947-da9fdc209889", "name": "p1rdt16911", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7e5d3205-621f-494a-ab6d-fad769918f9e"}}}}, {"uuid": "42ca79ed-f62f-4ac0-9102-c9659c386bdb", "name": "", "x": 38.70287643040543, "y": -122.37344445127026, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d53ff9fd-2b16-4026-88fa-2c112d4949c5", "name": "p1rdt16790-p1rdt487xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "42ca79ed-f62f-4ac0-9102-c9659c386bdb"}}}}, {"uuid": "c0e3a7e7-c16f-4b7d-a18a-6aab1ae6d4da", "name": "", "x": 38.703325006090246, "y": -122.37234754500905, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a1b5b099-df99-4729-a26d-f0882e93136f", "name": "p1rdt16790-p1rdt487x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c0e3a7e7-c16f-4b7d-a18a-6aab1ae6d4da"}}}}, {"uuid": "21750166-4903-4b4c-ba19-0e6b7f9489e0", "name": "", "x": 38.70318635641241, "y": -122.37390883465856, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b57b8e2b-62c2-49a0-801d-02cab8092ebd", "name": "p1rdt484", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "21750166-4903-4b4c-ba19-0e6b7f9489e0"}}}}, {"uuid": "2b9e9c66-5072-4da7-8003-57c1fa927b48", "name": "", "x": 38.70352176107739, "y": -122.37490290192596, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bd2f4b00-6e8b-4faa-a760-7c28f8d36a36", "name": "p1rdt486", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2b9e9c66-5072-4da7-8003-57c1fa927b48"}}}}, {"uuid": "d8957db5-cbe5-4d00-85fe-945d701e8053", "name": "", "x": 38.7035351825914, "y": -122.37510184014613, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "10c2463d-8563-4737-aa7d-e1195c0af9f6", "name": "p1rdt482", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d8957db5-cbe5-4d00-85fe-945d701e8053"}}}}, {"uuid": "d3f45a56-1323-4e5a-bb45-4854c58e77f0", "name": "", "x": 38.70367069880678, "y": -122.37631203298449, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e4064b6c-40b4-418b-95ab-4f9bb0363b14", "name": "p1rdt482-p1rdt485x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d3f45a56-1323-4e5a-bb45-4854c58e77f0"}}}}, {"uuid": "95d9dc99-1cb5-461e-a945-a57274c2eebd", "name": "", "x": 38.70062992258327, "y": -122.37444862489892, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d1eb09d-dff4-4fa3-b96f-ef59b63d6128", "name": "p1rdt477", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "95d9dc99-1cb5-461e-a945-a57274c2eebd"}}}}, {"uuid": "0a21d1b9-6ab1-49d5-a780-884c93792a4d", "name": "", "x": 38.70017599315202, "y": -122.374449032179, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5421facb-0713-404c-97e9-56669fc762b3", "name": "p1rdt476", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a21d1b9-6ab1-49d5-a780-884c93792a4d"}}}}, {"uuid": "5d69f592-01fb-4253-8b5f-8e5d349e1d8a", "name": "", "x": 38.7012326324604, "y": -122.37424787273476, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "85acd1fb-6da3-432a-9508-855ca991641b", "name": "p1rdt479", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5d69f592-01fb-4253-8b5f-8e5d349e1d8a"}}}}, {"uuid": "5cef3667-c445-4b39-bb1f-8c1ab800b88d", "name": "", "x": 38.70153006625403, "y": -122.37425678080724, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "82459f47-0c6f-4173-8c35-5a9fe5db9713", "name": "p1rdt454", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5cef3667-c445-4b39-bb1f-8c1ab800b88d"}}}}, {"uuid": "c3d04bfb-0722-4c14-b3e2-2a08a319c69e", "name": "", "x": 38.701876062215334, "y": -122.37492077650421, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "183de04a-a665-4112-a912-1df68b61d164", "name": "p1rdt455", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c3d04bfb-0722-4c14-b3e2-2a08a319c69e"}}}}, {"uuid": "98278fc0-28a5-42e6-bb31-86f9b808baa4", "name": "", "x": 38.70221801359906, "y": -122.37545476381091, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "59b616e5-76b8-406c-843f-5c71398af81b", "name": "p1rdt460", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "98278fc0-28a5-42e6-bb31-86f9b808baa4"}}}}, {"uuid": "dea738bd-0034-4241-af54-c69d1a1de21a", "name": "", "x": 38.702478034778096, "y": -122.37458202766794, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "86178159-ccd7-45a3-b711-ac237321d52a", "name": "p1rdt470", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "dea738bd-0034-4241-af54-c69d1a1de21a"}}}}, {"uuid": "17dc86f4-06a4-4f36-a0c0-053ed5d6918b", "name": "", "x": 38.702879570888186, "y": -122.37552155877664, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "69b5d686-dae0-44c5-a261-f1a73bcb168e", "name": "p1rdt483", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "17dc86f4-06a4-4f36-a0c0-053ed5d6918b"}}}}, {"uuid": "f3209dfb-0d4c-454f-b128-6d905623f51c", "name": "", "x": 38.703660453271056, "y": -122.37621331185325, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d899b807-b194-4f65-bad5-a39e8bc61906", "name": "p1rdt483-p1rdt485x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f3209dfb-0d4c-454f-b128-6d905623f51c"}}}}, {"uuid": "3cdd14db-f66c-40e6-a154-04d71f132931", "name": "", "x": 38.696234466020165, "y": -122.4029175301028, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "232adbbb-2715-44be-8db5-ee062ebf4e46", "name": "p1rdt279-p1rdt89x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3cdd14db-f66c-40e6-a154-04d71f132931"}}}}, {"uuid": "d36ac9a4-d6a8-48ba-a00f-294724d9c50b", "name": "", "x": 38.6936090734191, "y": -122.40307695118932, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "416118a8-65b7-4d9e-90a2-454f065bfddb", "name": "p1rdt279-p1rdt89xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d36ac9a4-d6a8-48ba-a00f-294724d9c50b"}}}}, {"uuid": "5a37f945-3b6c-4993-8b09-bd86f15e9ca8", "name": "", "x": 38.691921020060555, "y": -122.4037273791967, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ac4ad276-90cb-48c0-bfd0-1f2aa0233ce2", "name": "p1rdt89", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5a37f945-3b6c-4993-8b09-bd86f15e9ca8"}}}}, {"uuid": "1d7465a0-15cf-41d5-961d-c03eaf8bcc3c", "name": "", "x": 38.71273376728585, "y": -122.26236860525948, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d50d3e76-470b-47c2-ada2-da944962b322", "name": "p1rdt16427", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d7465a0-15cf-41d5-961d-c03eaf8bcc3c"}}}}, {"uuid": "832689e9-558f-4425-9e83-1b5db67ee44f", "name": "", "x": 38.713290303421466, "y": -122.26149228450026, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "18e3da78-83fc-4b8e-9d45-41adb9b753ad", "name": "p1rdt16424", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "832689e9-558f-4425-9e83-1b5db67ee44f"}}}}, {"uuid": "7fec0620-591f-4608-b812-80cf87d91f9d", "name": "", "x": 38.69570787792313, "y": -122.29851285731566, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8e35a4f7-19c1-4f59-9adc-b267f6088264", "name": "p1rdt16847", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7fec0620-591f-4608-b812-80cf87d91f9d"}}}}, {"uuid": "6704537b-9d53-40b6-b9e8-e67e3d651524", "name": "", "x": 38.71191996461427, "y": -122.26381070914681, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a6382a2-8c21-4cb4-a39b-3f1ac62cc705", "name": "p1rdt16427-p1rdt16847x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6704537b-9d53-40b6-b9e8-e67e3d651524"}}}}, {"uuid": "cc64522b-669a-4319-93fb-4f32f3956d1b", "name": "", "x": 38.68960809733261, "y": -122.30930023811142, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "61d5dee2-30f8-434d-8c03-76bccff72549", "name": "p1rdt16404", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc64522b-669a-4319-93fb-4f32f3956d1b"}}}}, {"uuid": "27628ce8-d3dd-4b33-8235-963ca36f778a", "name": "", "x": 38.69038163570117, "y": -122.31517993828531, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c5b51836-1807-4fab-b877-94a62021569f", "name": "p1rdt16394", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "27628ce8-d3dd-4b33-8235-963ca36f778a"}}}}, {"uuid": "420ccfac-7dbd-4510-83b6-2bea0e849955", "name": "", "x": 38.684262624044464, "y": -122.31767924836156, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b5a9e0f5-d824-4a76-a4f0-88aab072280e", "name": "p1rdt16603", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "420ccfac-7dbd-4510-83b6-2bea0e849955"}}}}, {"uuid": "88bd7eea-2f21-4a0d-879d-c3a70ed66def", "name": "", "x": 38.68314419705685, "y": -122.31905803173453, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "98a946e8-3c8a-49ec-be8a-5610c7fc596c", "name": "p1rdt16604", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "88bd7eea-2f21-4a0d-879d-c3a70ed66def"}}}}, {"uuid": "4fd2ad5d-d4e0-480c-a014-3cc3aa2fa98d", "name": "", "x": 38.68864067156756, "y": -122.34840259338564, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7ef71bd7-4c82-4296-a6ac-64516ffe96c5", "name": "p1rdt16604-p1rdt257x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4fd2ad5d-d4e0-480c-a014-3cc3aa2fa98d"}}}}, {"uuid": "f00cd8ba-b7f8-491a-b665-015a9277eadf", "name": "", "x": 38.68800685251441, "y": -122.34473682420163, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "282d8a89-8b14-476b-9e55-b310d8b9396d", "name": "p1rdt16604-p1rdt257x_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f00cd8ba-b7f8-491a-b665-015a9277eadf"}}}}, {"uuid": "1e961363-685e-4320-a9c9-c6a11ef0dc32", "name": "", "x": 38.68510682934324, "y": -122.35589682226349, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dcb27aab-e828-41a6-ad98-d197897a1a69", "name": "p1rdt209", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1e961363-685e-4320-a9c9-c6a11ef0dc32"}}}}, {"uuid": "a0cc6f33-f3de-4070-97bb-48c0aa09dfbf", "name": "", "x": 38.688681896745614, "y": -122.34841487443683, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3fb307f7-3690-4931-999a-4daab4d8c9e5", "name": "p1rdt257", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a0cc6f33-f3de-4070-97bb-48c0aa09dfbf"}}}}, {"uuid": "c26732ea-f986-41bc-95b2-b21b77a33f93", "name": "", "x": 38.68463781682152, "y": -122.35798033063733, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5d782d5e-3960-415c-9e33-6742777a5a0a", "name": "p1rdt210", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c26732ea-f986-41bc-95b2-b21b77a33f93"}}}}, {"uuid": "49ded750-7593-4589-9e1f-5c12c16bb481", "name": "", "x": 38.683540995258845, "y": -122.35679446809597, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b9401940-26a4-40f3-9b9a-5231a5c4e171", "name": "p1rdt211", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "49ded750-7593-4589-9e1f-5c12c16bb481"}}}}, {"uuid": "365a5752-e72f-4dc2-b314-1e000a8741e4", "name": "", "x": 38.68281023348963, "y": -122.35409734055312, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b89bfea1-97cd-41f7-af59-9602a3fc6c06", "name": "p1rdt278", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "365a5752-e72f-4dc2-b314-1e000a8741e4"}}}}, {"uuid": "8d37cf05-96a3-4d8e-bc5c-a40817f491c0", "name": "", "x": 38.68941008309863, "y": -122.37010832848992, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d1be5e34-ad5e-4c78-8067-8e0194c661a4", "name": "p1rdt210-p1rdt44x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8d37cf05-96a3-4d8e-bc5c-a40817f491c0"}}}}, {"uuid": "d48bab44-c136-4b4b-b5ef-2edb555ca1aa", "name": "", "x": 38.689335231948924, "y": -122.37012765218032, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f0b5743e-c3fd-49c7-879e-9be7d00c480f", "name": "p1rdt259-p1rdt44x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d48bab44-c136-4b4b-b5ef-2edb555ca1aa"}}}}, {"uuid": "d3241610-de63-4356-9931-09d85e05faa4", "name": "", "x": 38.68475989424937, "y": -122.36996130497471, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33a0a070-9cce-4a82-bd22-24a65f02ef97", "name": "p1rdt259", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d3241610-de63-4356-9931-09d85e05faa4"}}}}, {"uuid": "6861d9ef-ae9d-4bcd-b45d-e3cea1fee6da", "name": "", "x": 38.69119253254578, "y": -122.3723691075126, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7728581d-66fc-4e7e-b2b0-85fa02c90523", "name": "p1rdt43", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6861d9ef-ae9d-4bcd-b45d-e3cea1fee6da"}}}}, {"uuid": "99953f4d-982e-4c24-b529-2f7f64d2139a", "name": "", "x": 38.69217068541305, "y": -122.3732804512017, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1ea0531d-530c-4088-86a1-3de96a8938ea", "name": "p1rdt47", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "99953f4d-982e-4c24-b529-2f7f64d2139a"}}}}, {"uuid": "b9bda6ac-99c6-477c-960d-36334462a180", "name": "", "x": 38.692501666976284, "y": -122.37176768850954, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1667a8c6-aeb4-4f22-97b8-62ffefcc12a4", "name": "p1rdt48", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b9bda6ac-99c6-477c-960d-36334462a180"}}}}, {"uuid": "6fa6d556-40b3-48e9-9dd4-53c85726e76f", "name": "", "x": 38.69243929619441, "y": -122.37127733774665, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4f5cef5c-bcaf-4cd9-afbb-a18bd14dfcd4", "name": "p1rdt51", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6fa6d556-40b3-48e9-9dd4-53c85726e76f"}}}}, {"uuid": "a02913b0-c109-4683-9794-a5abb4af1cd6", "name": "", "x": 38.69084016635201, "y": -122.37219971004839, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7d99e903-3536-4a73-b0d5-ca11f5af6e32", "name": "p1rdt60", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a02913b0-c109-4683-9794-a5abb4af1cd6"}}}}, {"uuid": "b593050b-e132-4544-810f-e168f484e82a", "name": "", "x": 38.69044403976456, "y": -122.37227216228393, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2a4ccf80-2611-4089-9353-439809aa7854", "name": "p1rdt58", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b593050b-e132-4544-810f-e168f484e82a"}}}}, {"uuid": "faf45571-2233-4e14-8dbd-a4cb9bb93984", "name": "", "x": 38.690014841841176, "y": -122.3723741213489, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7238345a-1fc7-4f3f-bc8b-88cf7582c75c", "name": "p1rdt58-p1rdt69x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "faf45571-2233-4e14-8dbd-a4cb9bb93984"}}}}, {"uuid": "cb7173bb-4199-4353-9284-a0bc9e239ac0", "name": "", "x": 38.691521445820555, "y": -122.37639464686723, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bcea1fd6-3c51-48af-8528-d3d7bc8e4f01", "name": "p1rdt71", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb7173bb-4199-4353-9284-a0bc9e239ac0"}}}}, {"uuid": "6063cb06-32cd-4338-85e5-260df69cd2de", "name": "", "x": 38.69124250818054, "y": -122.37559619861726, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "744725a8-af2a-47cf-948f-9d453a932e32", "name": "p1rdt61", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6063cb06-32cd-4338-85e5-260df69cd2de"}}}}, {"uuid": "ddcdbfed-3171-4fa1-b47a-20f5a01c95ab", "name": "", "x": 38.69156944308755, "y": -122.37634466226288, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "eab6b8c5-ee7a-4779-b5eb-5205dbe5253c", "name": "p1rdt150-p1rdt71x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ddcdbfed-3171-4fa1-b47a-20f5a01c95ab"}}}}, {"uuid": "91db4e45-8d24-4b88-9548-edc1fcce5953", "name": "", "x": 38.69156345018649, "y": -122.37716473257039, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cf5b238a-832f-4f45-8a36-2248549e1723", "name": "p1rdt150-p1rdt71xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "91db4e45-8d24-4b88-9548-edc1fcce5953"}}}}, {"uuid": "ef35acf6-032c-4963-a01f-2230eacca63a", "name": "", "x": 38.686995650033, "y": -122.45197514226767, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0f2a0358-b10d-4b62-8f8d-9a5054fae87d", "name": "p1rdt376", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ef35acf6-032c-4963-a01f-2230eacca63a"}}}}, {"uuid": "8f3f93e7-1578-47b2-86b9-794346f706ac", "name": "", "x": 38.68750853010239, "y": -122.45098420292979, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d425a00d-c0e9-465d-9d9b-af4d64708fba", "name": "p1rdt374", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8f3f93e7-1578-47b2-86b9-794346f706ac"}}}}, {"uuid": "19d36e6c-2460-47b8-9e33-b4dcbcb80539", "name": "", "x": 38.68515597552901, "y": -122.45198911454673, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0de112ae-d04a-4673-98af-0699e4890429", "name": "p1rdt335-p1rdt376x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "19d36e6c-2460-47b8-9e33-b4dcbcb80539"}}}}, {"uuid": "af233a4c-7d45-41d9-a62c-72de519562f2", "name": "", "x": 38.67357675550989, "y": -122.4699912914106, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "101c6236-a474-45c8-b065-f5fa045b1107", "name": "p1rdt415", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "af233a4c-7d45-41d9-a62c-72de519562f2"}}}}, {"uuid": "9f19600a-edcd-46ba-ae35-6e1056793679", "name": "", "x": 38.67350163747049, "y": -122.4708045160677, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "71fa675e-bc20-46f7-b6f1-c88962f9f3cb", "name": "p1rdt417", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9f19600a-edcd-46ba-ae35-6e1056793679"}}}}, {"uuid": "bea72cbb-7842-4b45-817f-7fb1e09441f5", "name": "", "x": 38.67293062003175, "y": -122.46738711812904, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "19116f3c-29ae-4819-ba72-dd0f8afa5078", "name": "p1rdt415-p1rdt419x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bea72cbb-7842-4b45-817f-7fb1e09441f5"}}}}, {"uuid": "8d8841bf-aa27-4b28-ac54-de67f23e7732", "name": "", "x": 38.665494529835904, "y": -122.46043005782059, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9100fbd6-863e-48b2-94ed-aca1ef0947bd", "name": "p1rdt5098", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8d8841bf-aa27-4b28-ac54-de67f23e7732"}}}}, {"uuid": "5813a119-def8-4d45-b4bb-5d832ab51878", "name": "", "x": 38.66895816218114, "y": -122.45865330515163, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5258d4de-be4c-478d-b752-7f4efb0af0a5", "name": "p1rdt180", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5813a119-def8-4d45-b4bb-5d832ab51878"}}}}, {"uuid": "8c5463e5-55d2-48d9-b10f-67b2ccace9cd", "name": "", "x": 38.66514031344027, "y": -122.44753960527862, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9f273a36-c30d-4962-81f4-26f8d20e1cf4", "name": "p1rdt6584", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8c5463e5-55d2-48d9-b10f-67b2ccace9cd"}}}}, {"uuid": "71bd4c9c-02a9-484c-aca4-ac5ffddf68dd", "name": "", "x": 38.66464311110499, "y": -122.44791919098567, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4e257530-1fe2-410b-83a1-57789e6ddeda", "name": "p1rdt6578", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "71bd4c9c-02a9-484c-aca4-ac5ffddf68dd"}}}}, {"uuid": "6a0a739a-8c43-452d-ac2c-72a7a7e2d4d6", "name": "", "x": 38.66574098458345, "y": -122.44687980665202, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1648fe3-a7f9-47aa-b168-d2b56cf220e7", "name": "p1rdt6588", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6a0a739a-8c43-452d-ac2c-72a7a7e2d4d6"}}}}, {"uuid": "c3aa5e75-c547-4302-a29e-0a307e7e49c0", "name": "", "x": 38.66451724050103, "y": -122.44667705028046, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1d0a85a-62dc-46d2-bae1-d43d07743a34", "name": "p1rdt6591", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c3aa5e75-c547-4302-a29e-0a307e7e49c0"}}}}, {"uuid": "9e340273-38a6-48fe-869c-873f661a3243", "name": "", "x": 38.664682198133455, "y": -122.446168239027, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5291ea2b-6990-407b-b8d4-d6868bf37310", "name": "p1rdt6590", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9e340273-38a6-48fe-869c-873f661a3243"}}}}, {"uuid": "48f38dca-aa76-4927-9b84-65ffec914a19", "name": "", "x": 38.666084365577824, "y": -122.44838916371525, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d77add8e-ba22-4b44-9c0b-0bddc251a573", "name": "p1rdt6587", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "48f38dca-aa76-4927-9b84-65ffec914a19"}}}}, {"uuid": "70b56e2a-5e1c-4c12-a230-51d8f4fdc039", "name": "", "x": 38.6658846543716, "y": -122.44807809992015, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b918e583-d163-4136-aaf8-62085c7b0c17", "name": "p1rdt6584-p1rdt6587x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "70b56e2a-5e1c-4c12-a230-51d8f4fdc039"}}}}, {"uuid": "42b72520-be1d-4c12-a534-0a09bcbf8c0b", "name": "", "x": 38.66666084985903, "y": -122.45155897573034, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "68298e92-fca3-44e9-9271-f79be47c9c63", "name": "p1rdt6580", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "42b72520-be1d-4c12-a534-0a09bcbf8c0b"}}}}, {"uuid": "9700ef27-7399-42c3-a41c-ba76f3a5ba0d", "name": "", "x": 38.66481336487895, "y": -122.46776680294279, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cb3d775d-8d92-498b-989c-387278ec8e9e", "name": "p1rdt5098-p1rdt8169x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9700ef27-7399-42c3-a41c-ba76f3a5ba0d"}}}}, {"uuid": "f5375e9b-fd09-4d67-abb9-558b3cc8346c", "name": "", "x": 38.66954985597873, "y": -122.47289306798201, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16b7f1e9-3405-4c5f-96c7-d5c08d791907", "name": "p1rdt418", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f5375e9b-fd09-4d67-abb9-558b3cc8346c"}}}}, {"uuid": "0dd337d1-0ca4-48d8-8854-be2ef5efcfc5", "name": "", "x": 38.669198863842276, "y": -122.47439167095719, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3034e62-dd19-4ecb-bb39-6d0566e3a2ef", "name": "p1rdt414", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0dd337d1-0ca4-48d8-8854-be2ef5efcfc5"}}}}, {"uuid": "451ee1d6-69bb-4c5a-add8-b26af72700e1", "name": "", "x": 38.669612414212985, "y": -122.47279835298632, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ba78164d-d6ae-413b-8d24-067d8d38b28f", "name": "p1rdt416-p1rdt418x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "451ee1d6-69bb-4c5a-add8-b26af72700e1"}}}}, {"uuid": "13226904-e2e9-4814-b434-26821b104bc7", "name": "", "x": 38.671409309606254, "y": -122.47045206876079, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d16d5f5e-a376-4e39-a845-d2cde8800da3", "name": "p1rdt416", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "13226904-e2e9-4814-b434-26821b104bc7"}}}}, {"uuid": "48de8757-efa8-483a-8c9c-5c4f6109a371", "name": "", "x": 38.666461847991535, "y": -122.47096331177207, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1e3d41a7-06a4-460b-aa6c-3a60c8d2de10", "name": "p1rdt8201", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "48de8757-efa8-483a-8c9c-5c4f6109a371"}}}}, {"uuid": "ab0cc721-fe40-47c1-af8d-c996d017fdd8", "name": "", "x": 38.66526928202583, "y": -122.47027798516622, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "63928702-c44a-4e83-9cca-7ce77bdbd2b3", "name": "p1rdt8180-p1rdt8201x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ab0cc721-fe40-47c1-af8d-c996d017fdd8"}}}}, {"uuid": "22822696-ace4-4b6e-9db9-cf01859dd5b7", "name": "", "x": 38.658100245225164, "y": -122.48194171749711, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "246ad62e-5a10-4031-94e7-1732f58f1da9", "name": "p1rdt9055", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "22822696-ace4-4b6e-9db9-cf01859dd5b7"}}}}, {"uuid": "42866221-5545-4352-b430-fcf9cba1b4d0", "name": "", "x": 38.658393900938755, "y": -122.48112128391094, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cd9ea283-dbd2-4f38-b298-86a191c99bd2", "name": "p1rdt6265-p1rdt9055x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "42866221-5545-4352-b430-fcf9cba1b4d0"}}}}, {"uuid": "e03f9558-f8a9-4c77-88dd-fd9becc4fa78", "name": "", "x": 38.66056852061021, "y": -122.48035453306898, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2d316c13-77c1-4412-baf9-801f7e5ae407", "name": "p1rdt6265", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e03f9558-f8a9-4c77-88dd-fd9becc4fa78"}}}}, {"uuid": "60ff6017-72bc-4e90-890f-a061fd92703b", "name": "", "x": 38.65517194896592, "y": -122.48092661777345, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "30adfcd5-405b-47ea-be54-55c5a47c835f", "name": "p1rdt5560-p1rdt9055x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "60ff6017-72bc-4e90-890f-a061fd92703b"}}}}, {"uuid": "486eb953-e908-4a2e-a027-ef91dd99a6d8", "name": "", "x": 38.65725844991055, "y": -122.4811294760667, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "708f65d6-b869-4d26-930d-0e669caf4ffb", "name": "p1rdt5560-p1rdt9055xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "486eb953-e908-4a2e-a027-ef91dd99a6d8"}}}}, {"uuid": "28380f22-c0fa-475d-b399-b1cf74e2d018", "name": "", "x": 38.65230276217263, "y": -122.47461858577147, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d2ea25e-3d48-4b1d-9e52-768752de2e09", "name": "p1rdt7737", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "28380f22-c0fa-475d-b399-b1cf74e2d018"}}}}, {"uuid": "8f2f7c97-e09b-479b-837d-464111202a96", "name": "", "x": 38.65261575836355, "y": -122.4740602281008, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d142315b-a247-4a4d-a178-73e3c150a188", "name": "p1rdt7753", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8f2f7c97-e09b-479b-837d-464111202a96"}}}}, {"uuid": "5e5b7087-e9b0-48be-b147-19fd7f3264c1", "name": "", "x": 38.65184325416811, "y": -122.47515027973938, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4413ca7f-fdd1-484e-a0ba-3ff2447ebfef", "name": "p1rdt7791", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5e5b7087-e9b0-48be-b147-19fd7f3264c1"}}}}, {"uuid": "5d9e1eac-53fe-4947-b515-8daa7226ff69", "name": "", "x": 38.65207704845808, "y": -122.47515639717327, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0946738d-95de-4ad6-9d56-c043cb64c0e4", "name": "p1rdt7737-p1rdt7791x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5d9e1eac-53fe-4947-b515-8daa7226ff69"}}}}, {"uuid": "2826c794-b792-4ddc-8cc3-299a0c520ed3", "name": "", "x": 38.650951110512295, "y": -122.47644062493562, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "02351140-e632-49e2-83e4-7e5bc1c8856a", "name": "p1rdt7286", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2826c794-b792-4ddc-8cc3-299a0c520ed3"}}}}, {"uuid": "bd1fc43e-5a7b-4ff3-a94b-13041d21829c", "name": "", "x": 38.650648984972726, "y": -122.4768636646543, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8f8375b7-7bdd-409c-9fa1-5c13bd233364", "name": "p1rdt7289", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bd1fc43e-5a7b-4ff3-a94b-13041d21829c"}}}}, {"uuid": "1021a436-70ff-46d2-a2b1-36a6647e3118", "name": "", "x": 38.64944561704761, "y": -122.4757921819993, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4afa9bec-d8da-4449-ab96-9f875bae3c33", "name": "p1rdt7293", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1021a436-70ff-46d2-a2b1-36a6647e3118"}}}}, {"uuid": "69c7c6c7-1a98-4695-8108-a198c0b20ae5", "name": "", "x": 38.65290986333587, "y": -122.48317621935037, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0c83b6ee-20fc-4ca0-a778-44735283afd5", "name": "p1rdt5568", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "69c7c6c7-1a98-4695-8108-a198c0b20ae5"}}}}, {"uuid": "4426b99d-b785-4e5c-8972-5c972cdc1537", "name": "", "x": 38.653647469597004, "y": -122.48368389304464, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c8aa126c-9b2b-4ae0-a4fc-36d4201762a0", "name": "p1rdt5551-p1rdt5568xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4426b99d-b785-4e5c-8972-5c972cdc1537"}}}}, {"uuid": "ead5b8ed-3484-430c-a8ae-dc48d05070f0", "name": "", "x": 38.653032242675096, "y": -122.48324009208464, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "65eb08cf-6350-410a-88c2-3b318d3a262a", "name": "p1rdt5551-p1rdt5568xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ead5b8ed-3484-430c-a8ae-dc48d05070f0"}}}}, {"uuid": "3e1daa0b-ddcc-4ad5-9f93-673e981a9174", "name": "", "x": 38.652900682241246, "y": -122.48322892310364, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "64aba8d5-1dd3-4741-a8ba-26801e275ba8", "name": "p1rdt5551-p1rdt5568xxxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e1daa0b-ddcc-4ad5-9f93-673e981a9174"}}}}, {"uuid": "231d6b41-e4d1-42bc-9618-d294db1cb3a1", "name": "", "x": 38.65348179379366, "y": -122.4842621130032, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0c49b671-0b2b-43c9-bcb5-21c7b7e716ce", "name": "p1rdt5548-p1rdt5577xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "231d6b41-e4d1-42bc-9618-d294db1cb3a1"}}}}, {"uuid": "ea0b67e7-491e-44da-a05f-d51bc1dc6c07", "name": "", "x": 38.652151086540165, "y": -122.48369686652708, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fead5749-3ba7-4ead-a604-e8adbd18f8c2", "name": "p1rdt5548-p1rdt5577xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ea0b67e7-491e-44da-a05f-d51bc1dc6c07"}}}}, {"uuid": "202ca4fc-f7c0-4c03-85d6-93e58cf5c199", "name": "", "x": 38.67222953111598, "y": -122.47625831645591, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c51ccb17-eed6-4ce0-b839-e7b26001fe3e", "name": "p1rdt304", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "202ca4fc-f7c0-4c03-85d6-93e58cf5c199"}}}}, {"uuid": "cf4d842f-4898-4504-99b0-7952f53b6158", "name": "", "x": 38.67878840609695, "y": -122.47525103045935, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "08e378d4-4ca6-4c9e-93fa-36ff87a3cf0f", "name": "p1rdt182", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cf4d842f-4898-4504-99b0-7952f53b6158"}}}}, {"uuid": "78af3e58-f400-406c-bd8e-efa3077f8637", "name": "", "x": 38.67077336251232, "y": -122.47582856074445, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7b936973-54dc-41e7-a413-8932c31f0793", "name": "p1rdt305", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "78af3e58-f400-406c-bd8e-efa3077f8637"}}}}, {"uuid": "8019fa58-ddff-4d58-9d54-6ba68f47b6af", "name": "", "x": 38.670527094141356, "y": -122.4798175179331, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9672c49b-8316-4907-b204-7505483210b0", "name": "p1rdt303", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8019fa58-ddff-4d58-9d54-6ba68f47b6af"}}}}, {"uuid": "d4d6f94f-f802-4308-9407-6b6546edf927", "name": "", "x": 38.66807769283756, "y": -122.48429523464395, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3ad84ef4-4dcc-42f7-99ed-b8d21cebc465", "name": "p1rdt177", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d4d6f94f-f802-4308-9407-6b6546edf927"}}}}, {"uuid": "4d1b6692-00b6-48e4-badf-57286e495511", "name": "", "x": 38.67120072595356, "y": -122.49044397744001, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "57a78c71-e5a8-4dfd-8359-e368b7b198fa", "name": "p1rdt306", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d1b6692-00b6-48e4-badf-57286e495511"}}}}, {"uuid": "ceeea650-e1b4-4e66-90cd-57fbde5fae70", "name": "", "x": 38.68186286213555, "y": -122.49395729632428, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6912a245-ac1c-4ddd-b021-3bc35cbbe2c5", "name": "p1rdt178", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ceeea650-e1b4-4e66-90cd-57fbde5fae70"}}}}, {"uuid": "365d0a90-7e2b-4a3a-b6cb-9ec8a40f3ee9", "name": "", "x": 38.65563774049388, "y": -122.48693753355442, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3f91816-7c3f-4fc7-98a5-6dee55e52e9f", "name": "p1rdt8105", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "365d0a90-7e2b-4a3a-b6cb-9ec8a40f3ee9"}}}}, {"uuid": "5275819a-01e1-4e57-8757-365b836edff4", "name": "", "x": 38.65332887399879, "y": -122.4877199764791, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f2c69fef-4afb-4bb3-9828-096b812de54a", "name": "p1rdt8111", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5275819a-01e1-4e57-8757-365b836edff4"}}}}, {"uuid": "d6c9dab0-2688-471e-9207-5a682545447e", "name": "", "x": 38.65397853262116, "y": -122.48734763535352, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "37229b7c-80a2-4d01-af6a-818bdfcc1f54", "name": "p1rdt8105-p1rdt8111x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d6c9dab0-2688-471e-9207-5a682545447e"}}}}, {"uuid": "0cd3484e-7c70-4cad-97ef-8a3cfa794239", "name": "", "x": 38.653298743960605, "y": -122.48786735210962, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fc34073b-94f6-4c75-8144-8f624bac9cc7", "name": "p1rdt8146", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0cd3484e-7c70-4cad-97ef-8a3cfa794239"}}}}, {"uuid": "10dac104-0d6e-41d9-8fc3-8f17a40b3a12", "name": "", "x": 38.65338804911886, "y": -122.48767001324168, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9929e0d4-3e33-4f5f-b718-6a629cc52242", "name": "p1rdt8111-p1rdt8138xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "10dac104-0d6e-41d9-8fc3-8f17a40b3a12"}}}}, {"uuid": "0e5fd983-d874-4f22-ad29-f0f286977194", "name": "", "x": 38.65220693629279, "y": -122.48673933307626, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3a54311-da27-45d7-95c3-eee07761fbe4", "name": "p1rdt8111-p1rdt8138x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0e5fd983-d874-4f22-ad29-f0f286977194"}}}}, {"uuid": "fa457226-617f-4a99-b897-6225df98cda6", "name": "", "x": 38.706834415392834, "y": -122.42490821272983, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b801037a-e1bb-4c5c-8d18-ed285c8c1d3b", "name": "p1rdt251", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa457226-617f-4a99-b897-6225df98cda6"}}}}, {"uuid": "e5389bd2-8ce8-4204-97bd-aee05bb56864", "name": "", "x": 38.70723865207442, "y": -122.42480038439254, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "69b2ee46-ab5f-48c8-a26b-170ed2b57fcb", "name": "p1rdt252", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e5389bd2-8ce8-4204-97bd-aee05bb56864"}}}}, {"uuid": "39cabe12-2278-40ba-9afa-b474d3d17fae", "name": "", "x": 38.70153411123505, "y": -122.42253878409483, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f3dfe357-889d-42e0-a59a-821c9f843456", "name": "p1rdt446", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "39cabe12-2278-40ba-9afa-b474d3d17fae"}}}}, {"uuid": "13201431-68c1-4d67-ab30-848923d4ecd2", "name": "", "x": 38.696509390287886, "y": -122.37572644565952, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2cf3136f-6dbe-4ed7-b9cb-e9f73b191f76", "name": "p1rdt481", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "13201431-68c1-4d67-ab30-848923d4ecd2"}}}}, {"uuid": "bb919fde-343d-4af8-b649-1a441fcbe691", "name": "", "x": 38.69562927890001, "y": -122.37574956469108, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a180b972-cf0e-4a2e-9bcf-a0ad90bb3d83", "name": "p1rdt468", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bb919fde-343d-4af8-b649-1a441fcbe691"}}}}, {"uuid": "116b3e5d-3798-43ce-a998-c53f4ba9e37b", "name": "", "x": 38.696842869414894, "y": -122.37573504621221, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c39140c6-8892-480a-81b9-738c67ed1591", "name": "p1rdt475", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "116b3e5d-3798-43ce-a998-c53f4ba9e37b"}}}}, {"uuid": "ee055b10-cabe-4d1d-8c63-0991b1e0c92a", "name": "", "x": 38.697374719659294, "y": -122.37576492139411, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fc35f44e-d8d9-41d0-b014-caa3d8d7a91e", "name": "p1rdt461", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ee055b10-cabe-4d1d-8c63-0991b1e0c92a"}}}}, {"uuid": "ec600ace-eeeb-4966-b6d6-37f79e672b78", "name": "", "x": 38.69825572660699, "y": -122.37579303954152, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2eba354c-f4bf-4c49-a8ad-998ab9489e5a", "name": "p1rdt478", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ec600ace-eeeb-4966-b6d6-37f79e672b78"}}}}, {"uuid": "84847f25-821b-400e-a799-cd3cf8fa9ba5", "name": "", "x": 38.69843582959593, "y": -122.37576847475998, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a94f7afe-e8b0-4b24-8196-6b05e98c3830", "name": "p1rdt465", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "84847f25-821b-400e-a799-cd3cf8fa9ba5"}}}}, {"uuid": "b3af6a2d-b395-43bc-805c-a33d0eac214e", "name": "", "x": 38.699753883698804, "y": -122.37577873918647, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0fa474a3-1d6b-454b-9170-6a8d13789c43", "name": "p1rdt488", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b3af6a2d-b395-43bc-805c-a33d0eac214e"}}}}, {"uuid": "bea7aa80-5487-4162-a59d-41c01b796663", "name": "", "x": 38.699988606794975, "y": -122.37585719796019, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7637cfdb-6a14-4313-95d4-e25beba178f3", "name": "p1rdt463", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bea7aa80-5487-4162-a59d-41c01b796663"}}}}, {"uuid": "d0ae0a33-8d9d-4e46-baff-4744dbc33df5", "name": "", "x": 38.701244304283534, "y": -122.3764327877571, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7627cbc6-c54a-432b-8cba-59e448f6d45a", "name": "p1rdt82", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d0ae0a33-8d9d-4e46-baff-4744dbc33df5"}}}}, {"uuid": "feb8f7d0-ddd9-49a4-9035-25a0f5fa1802", "name": "", "x": 38.701568593856685, "y": -122.37703593173678, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "36bfd1f1-80ca-4b7d-a68b-9aa77ceff96e", "name": "p1rdt78", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "feb8f7d0-ddd9-49a4-9035-25a0f5fa1802"}}}}, {"uuid": "61ff3521-9b61-4365-b8d2-19db719ca287", "name": "", "x": 38.70158095287149, "y": -122.37746615460954, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6fc415bc-f457-4e9f-bbd4-783a71b67ad6", "name": "p1rdt85", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "61ff3521-9b61-4365-b8d2-19db719ca287"}}}}, {"uuid": "8dc7b52a-7147-455e-9b0a-451e50e06055", "name": "", "x": 38.701575510504455, "y": -122.37770642721351, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "063e25be-2abb-49ae-b459-ddd08ba93bb3", "name": "p1rdt81", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8dc7b52a-7147-455e-9b0a-451e50e06055"}}}}, {"uuid": "f44e3248-9cf9-47bd-87c6-7258b7bcf930", "name": "", "x": 38.701531800163046, "y": -122.37795980901173, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b32c9763-ddff-435b-a28c-8f65111c6cb2", "name": "p1rdt79", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f44e3248-9cf9-47bd-87c6-7258b7bcf930"}}}}, {"uuid": "8e69fd51-7eb9-4fd3-b2d6-8a48a810d9a3", "name": "", "x": 38.70139571168677, "y": -122.37841744526864, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dfbb212a-9882-4468-86ac-578c93fde1d8", "name": "p1rdt76", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8e69fd51-7eb9-4fd3-b2d6-8a48a810d9a3"}}}}, {"uuid": "28739721-e132-4b04-86a9-56f6ea3da7da", "name": "", "x": 38.70130561638834, "y": -122.3796880720142, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7c543753-fa26-41df-b7a6-3664395c0d45", "name": "p1rdt31", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "28739721-e132-4b04-86a9-56f6ea3da7da"}}}}, {"uuid": "62463952-0717-41bf-9839-1f1550b7af30", "name": "", "x": 38.70185707821067, "y": -122.38044898464344, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e8dcdfef-b40e-4f1c-9b7c-e84846f68c5a", "name": "p1rdt36", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "62463952-0717-41bf-9839-1f1550b7af30"}}}}, {"uuid": "9101c6b5-0c1a-49cf-a987-2070793803fa", "name": "", "x": 38.702744402653344, "y": -122.38060588011899, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "834e959c-8ee6-4fff-b1fc-54c20fc0f20b", "name": "p1rdt32", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9101c6b5-0c1a-49cf-a987-2070793803fa"}}}}, {"uuid": "f4a0f3e7-a651-456a-8d40-60652fb7afc2", "name": "", "x": 38.70315433826527, "y": -122.38036878848187, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "80331f15-8b31-454c-a289-49cb79923252", "name": "p1rdt234", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f4a0f3e7-a651-456a-8d40-60652fb7afc2"}}}}, {"uuid": "2d354866-5878-4547-971d-7695b52967f8", "name": "", "x": 38.70342202813448, "y": -122.37754091771487, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8f5ed5d5-93fc-4f3c-a78b-df7019863b67", "name": "p1rdt233", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2d354866-5878-4547-971d-7695b52967f8"}}}}, {"uuid": "ff295c7d-9e68-4562-91ff-1c05b39881db", "name": "", "x": 38.70364344183274, "y": -122.37626641561926, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "445f61a4-8045-4558-a3c1-bb44336737ec", "name": "p1rdt485", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ff295c7d-9e68-4562-91ff-1c05b39881db"}}}}, {"uuid": "5593c229-b3c9-4d0d-bc4f-0be1328a3af8", "name": "", "x": 38.70340510620564, "y": -122.37837704887761, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "190d6c51-94b6-462e-8fee-cce57f1ab66d", "name": "p1rdt236", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5593c229-b3c9-4d0d-bc4f-0be1328a3af8"}}}}, {"uuid": "673128da-caab-4282-9357-c1d62f2c2ece", "name": "", "x": 38.70289903823247, "y": -122.38150952694326, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "14b85850-d83e-4a5e-83c3-ccb485bb85aa", "name": "p1rdt235", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "673128da-caab-4282-9357-c1d62f2c2ece"}}}}, {"uuid": "a374df4b-0d29-44b7-9bac-64b8948c031e", "name": "", "x": 38.70241528605291, "y": -122.38205420706528, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4fa95a19-0e0a-49b3-bb86-7103fbaa4110", "name": "p1rdt30", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a374df4b-0d29-44b7-9bac-64b8948c031e"}}}}, {"uuid": "27886ea0-4c87-411a-b113-73a096f62fda", "name": "", "x": 38.70180761889256, "y": -122.38302545203672, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "edc22f66-e919-448e-b990-76033c281d43", "name": "p1rdt35", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "27886ea0-4c87-411a-b113-73a096f62fda"}}}}, {"uuid": "236076ef-b7c1-4fb9-8263-b3a045928901", "name": "", "x": 38.70163145569769, "y": -122.3837974760483, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1e9f4b13-5fb5-46b2-9258-83582d47d61a", "name": "p1rdt84", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "236076ef-b7c1-4fb9-8263-b3a045928901"}}}}, {"uuid": "7b7eef78-375f-456d-852b-00b1d572d559", "name": "", "x": 38.70166339444126, "y": -122.38472871487578, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f55e4012-a11d-4883-baac-9c013aff6058", "name": "p1rdt33", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7b7eef78-375f-456d-852b-00b1d572d559"}}}}, {"uuid": "247189ff-cc8a-46c5-a8c4-302aa83aca0a", "name": "", "x": 38.7017418716262, "y": -122.38534278443267, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a01c83d1-4adb-4b2a-8de3-441d7c1dd054", "name": "p1rdt39", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "247189ff-cc8a-46c5-a8c4-302aa83aca0a"}}}}, {"uuid": "bd8ee146-d20a-4486-a4a6-8cc95bd84b7d", "name": "", "x": 38.701720915150304, "y": -122.38552827095313, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dc531967-1a7b-4424-83ee-e1131c6fd94c", "name": "p1rdt73", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bd8ee146-d20a-4486-a4a6-8cc95bd84b7d"}}}}, {"uuid": "93962e5e-5dec-4444-8f0a-d3dcffea81d1", "name": "", "x": 38.70178214782518, "y": -122.38611126603591, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "510ea93c-7dd1-4fa3-ba3f-6c362856c7c1", "name": "p1rdt75", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "93962e5e-5dec-4444-8f0a-d3dcffea81d1"}}}}, {"uuid": "31ad3b66-1fa1-490b-bef3-43e3c128eca3", "name": "", "x": 38.70181286232661, "y": -122.3868125146921, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0aa0b7c2-9d55-4faf-8778-76a6f23bcf3e", "name": "p1rdt83", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "31ad3b66-1fa1-490b-bef3-43e3c128eca3"}}}}, {"uuid": "526cccc9-2c2a-4ed8-afcb-3a615e136d3a", "name": "", "x": 38.70215867171945, "y": -122.38789186166865, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b03f8e29-a5b2-4bed-b68c-219276674b6a", "name": "p1rdt80", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "526cccc9-2c2a-4ed8-afcb-3a615e136d3a"}}}}, {"uuid": "be8ad268-a3cf-443d-a0ec-9b264dda0a90", "name": "", "x": 38.697976462001364, "y": -122.39194580684853, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6e26e5dc-8c98-4fcd-b125-3265eb00f3f2", "name": "p1rdt263", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "be8ad268-a3cf-443d-a0ec-9b264dda0a90"}}}}, {"uuid": "e49f82ab-a211-49e8-85c6-8633476c0695", "name": "", "x": 38.69710687368567, "y": -122.39904337583427, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "add5e39f-f02e-4a61-a156-d5721cec25d5", "name": "p1rdt277", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e49f82ab-a211-49e8-85c6-8633476c0695"}}}}, {"uuid": "78223a48-666e-4fcb-bebe-4311d1ecde6b", "name": "", "x": 38.69810207651738, "y": -122.40314189875019, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "186ffdfe-2346-4218-bd6b-b813ea6b3b62", "name": "p1rdt276", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "78223a48-666e-4fcb-bebe-4311d1ecde6b"}}}}, {"uuid": "01232a55-73d4-431f-b4e2-ab26730f7c11", "name": "", "x": 38.690000449751984, "y": -122.37232330919996, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9396562e-4f87-4e04-b248-502b851fe19e", "name": "p1rdt69", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "01232a55-73d4-431f-b4e2-ab26730f7c11"}}}}, {"uuid": "c3618ba1-cc9e-482c-b16e-58f3afed5c90", "name": "", "x": 38.689693582568, "y": -122.3712823494636, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b1bf1493-fb0d-40b4-8953-42e851a128d1", "name": "p1rdt44-p1rdt69x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c3618ba1-cc9e-482c-b16e-58f3afed5c90"}}}}, {"uuid": "abafd7f4-0cb8-4405-b252-6d3fa278f0eb", "name": "", "x": 38.68937758378194, "y": -122.37014905131693, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d9ee2ff-e2bc-4d76-b173-5ba5cc48c9b3", "name": "p1rdt44", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "abafd7f4-0cb8-4405-b252-6d3fa278f0eb"}}}}, {"uuid": "03aced16-e52e-475b-a740-04f3b1bf820b", "name": "", "x": 38.69011879726304, "y": -122.37274288833332, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f5b5b3ae-f657-4fd4-a311-ab1dbe9d749e", "name": "p1rdt41", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "03aced16-e52e-475b-a740-04f3b1bf820b"}}}}, {"uuid": "36d91d90-2790-49d6-b119-47c834f4234b", "name": "", "x": 38.690503780808164, "y": -122.3733294899771, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5a898f4c-f522-4e69-be4a-e935e339e011", "name": "p1rdt54", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "36d91d90-2790-49d6-b119-47c834f4234b"}}}}, {"uuid": "aaa1d980-d87f-4d7b-ac4e-4b123d9d1355", "name": "", "x": 38.690543520806486, "y": -122.37401904570497, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a778171c-22a1-4320-9e3c-43888d734e34", "name": "p1rdt42", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aaa1d980-d87f-4d7b-ac4e-4b123d9d1355"}}}}, {"uuid": "947f010e-99dd-41e2-96b2-bffab8e65938", "name": "", "x": 38.69014061173149, "y": -122.37513434619457, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "29a79372-9c75-4a9c-81df-a7491b87e58a", "name": "p1rdt45", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "947f010e-99dd-41e2-96b2-bffab8e65938"}}}}, {"uuid": "b407de02-85af-4ee9-8cd1-d1819848c2a8", "name": "", "x": 38.69057727021838, "y": -122.39183596993689, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "12451cbc-eb14-4814-b274-12eb2241c78a", "name": "p1rdt150", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b407de02-85af-4ee9-8cd1-d1819848c2a8"}}}}, {"uuid": "20710a8e-91b2-4c39-a742-bbc05da3aea2", "name": "", "x": 38.690031528872375, "y": -122.37717801542972, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "666bb367-692a-4127-8f77-d86d651768a1", "name": "p1rdt150-p1rdt45x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "20710a8e-91b2-4c39-a742-bbc05da3aea2"}}}}, {"uuid": "8ae76df5-4eda-4ab4-b4a6-5a6cc3bc0572", "name": "", "x": 38.694133300872906, "y": -122.39690517522077, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ba0ef4a3-43ba-469b-8ce8-ca7a5a984071", "name": "p1rdt260", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8ae76df5-4eda-4ab4-b4a6-5a6cc3bc0572"}}}}, {"uuid": "d3ad0f96-fc3e-4803-a9e7-5fb27f447339", "name": "", "x": 38.693518695228036, "y": -122.39600590196753, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e885b3e5-18fb-4454-b8e7-d82b4c72f6e8", "name": "p1rdt150-p1rdt260x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d3ad0f96-fc3e-4803-a9e7-5fb27f447339"}}}}, {"uuid": "3163f4ff-97fe-45fc-a29c-50928b93536f", "name": "", "x": 38.69620897416254, "y": -122.40296066033352, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "153bb615-5ee5-4eec-bcf7-94ea0098aeb6", "name": "p1rdt279", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3163f4ff-97fe-45fc-a29c-50928b93536f"}}}}, {"uuid": "a8a933b7-550e-458e-a813-a122f7e87ffb", "name": "", "x": 38.69807607310296, "y": -122.40309926707015, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7140d97e-416e-47ec-9f86-46ad6f9abece", "name": "p1rdt276-p1rdt279x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a8a933b7-550e-458e-a813-a122f7e87ffb"}}}}, {"uuid": "aa93ecf8-6317-4e7e-8477-1c893b5d069b", "name": "", "x": 38.69819542243506, "y": -122.40314157925388, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c3ca9bee-26b0-4ef4-8555-6494ffdd6a17", "name": "p1rdt237-p1rdt276x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "aa93ecf8-6317-4e7e-8477-1c893b5d069b"}}}}, {"uuid": "0ca3bc30-a32a-4240-89b1-4f3e26a789a5", "name": "", "x": 38.69933414700199, "y": -122.4089172598197, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "767b59ef-ecd9-4b17-8233-2033a02b2971", "name": "p1rdt237-p1rdt276xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0ca3bc30-a32a-4240-89b1-4f3e26a789a5"}}}}, {"uuid": "3781b958-1ce3-4d50-b11e-7a414f9249c8", "name": "", "x": 38.70123224209162, "y": -122.42082954062212, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "11571d26-573f-49f7-99fd-828dde97afd8", "name": "p1rdt445", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3781b958-1ce3-4d50-b11e-7a414f9249c8"}}}}, {"uuid": "597b89b3-1ee6-4948-af20-fb9177ddd8a9", "name": "", "x": 38.69940195487717, "y": -122.41580111174017, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b8c8b8f8-7a41-4d16-b509-2d7c7af9509d", "name": "p1rdt237", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "597b89b3-1ee6-4948-af20-fb9177ddd8a9"}}}}, {"uuid": "6c603289-21a7-43aa-9f84-f41ba7f6e016", "name": "", "x": 38.701258982520905, "y": -122.42203851637785, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "10620dcc-049c-4417-b4ac-922a56c0d4a2", "name": "p1rdt438", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c603289-21a7-43aa-9f84-f41ba7f6e016"}}}}, {"uuid": "cc52b747-000a-4eb9-8b06-9966684ef16d", "name": "", "x": 38.689358814642475, "y": -122.44266212701238, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e71eb2d5-cd10-498d-b9eb-ae337b2f8af6", "name": "p1rdt28", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc52b747-000a-4eb9-8b06-9966684ef16d"}}}}, {"uuid": "564731ca-f9e0-45c3-9794-cebe993202f6", "name": "", "x": 38.68721403983049, "y": -122.44207560107604, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5b238dc5-7d8e-4b2d-8449-4dc212d7d227", "name": "p1rdt29", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "564731ca-f9e0-45c3-9794-cebe993202f6"}}}}, {"uuid": "9d4e97bd-a73c-4ed1-aad4-1c56fcfeb7f5", "name": "", "x": 38.68513046534505, "y": -122.45203222088253, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b07c4a6-39a7-4521-bce7-3f1ca0ff4a66", "name": "p1rdt335", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9d4e97bd-a73c-4ed1-aad4-1c56fcfeb7f5"}}}}, {"uuid": "74004cc2-1c07-40eb-b690-9af1a3df1329", "name": "", "x": 38.672940788437906, "y": -122.46748581101485, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d2efeaf5-2055-4718-a064-7c5e00b7d87d", "name": "p1rdt335-p1rdt419x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "74004cc2-1c07-40eb-b690-9af1a3df1329"}}}}, {"uuid": "bd6d72a5-0be7-43d2-8bdd-a587714676de", "name": "", "x": 38.670797093100916, "y": -122.46774549226095, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4cf05060-0a39-49a9-a761-79fb136e2965", "name": "p1rdt420", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bd6d72a5-0be7-43d2-8bdd-a587714676de"}}}}, {"uuid": "a7442dd9-11f1-4aa7-b011-7fe9acac7b86", "name": "", "x": 38.67291356677607, "y": -122.46744017800017, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "81cfd2a2-295c-4b73-abba-05ffee810523", "name": "p1rdt419", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a7442dd9-11f1-4aa7-b011-7fe9acac7b86"}}}}, {"uuid": "31607d9b-e1df-4994-b05a-19e19b826848", "name": "", "x": 38.66669420046755, "y": -122.46979269819516, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2eb3d4eb-71fc-46f3-b588-d223568c411c", "name": "p1rdt8167", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "31607d9b-e1df-4994-b05a-19e19b826848"}}}}, {"uuid": "755607de-9ddc-4da7-90ee-fa14c364aa50", "name": "", "x": 38.66526952797366, "y": -122.47022403577644, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3c93a476-4ad5-41cd-a07b-e2ccc9ef2c3b", "name": "p1rdt8180", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "755607de-9ddc-4da7-90ee-fa14c364aa50"}}}}, {"uuid": "ba2d9fb2-095f-4bb5-8b20-417d9d825944", "name": "", "x": 38.66479901416412, "y": -122.46771598894871, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f6bdb2cf-9373-4d56-a5f9-cb8fa9c67e55", "name": "p1rdt8169", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ba2d9fb2-095f-4bb5-8b20-417d9d825944"}}}}, {"uuid": "1859b7c8-60c3-43f1-b2f2-20c000be300e", "name": "", "x": 38.66152380322448, "y": -122.47383733708416, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "498a07ee-e12b-459a-a01f-f663a4a8428a", "name": "p1rdt8174-p1rdt8180x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1859b7c8-60c3-43f1-b2f2-20c000be300e"}}}}, {"uuid": "91f2ce3d-3736-4c91-8287-a517bda95203", "name": "", "x": 38.6604983255136, "y": -122.47346682060977, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8997dae6-8970-4762-98e9-0617375633d6", "name": "p1rdt8195", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "91f2ce3d-3736-4c91-8287-a517bda95203"}}}}, {"uuid": "d9edddcb-9fa1-475f-9bf6-503a8412b109", "name": "", "x": 38.66147939586647, "y": -122.47384646091422, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6b0f9433-e0a3-458a-8687-c9cf38d0bbb3", "name": "p1rdt8174", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d9edddcb-9fa1-475f-9bf6-503a8412b109"}}}}, {"uuid": "cb97c63c-d7ff-485c-9dfe-4e26ebff9985", "name": "", "x": 38.658272650826795, "y": -122.47501655241358, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "081feb5c-d5d5-405e-85d4-f1dd0916fc3d", "name": "p1rdt7757", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb97c63c-d7ff-485c-9dfe-4e26ebff9985"}}}}, {"uuid": "14c338c8-ab4b-486b-a84b-27dda3b552bc", "name": "", "x": 38.655197924044465, "y": -122.48096925268166, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "68117bef-16c5-40c9-9356-76ef5c056650", "name": "p1rdt5560", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "14c338c8-ab4b-486b-a84b-27dda3b552bc"}}}}, {"uuid": "cd9b5143-5e3c-47a8-8356-96be17119efb", "name": "", "x": 38.6571578603823, "y": -122.47877412021943, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b64b7bd6-06e4-45f7-b987-efc7d09b91f8", "name": "p1rdt5560-p1rdt7757x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cd9b5143-5e3c-47a8-8356-96be17119efb"}}}}, {"uuid": "7a8878fb-4cdc-4fa9-b40d-55bc8657a357", "name": "", "x": 38.6544084693578, "y": -122.48126098888899, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8444c9ea-ff7a-4b0a-9ea6-9c18770565cb", "name": "p1rdt5564", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7a8878fb-4cdc-4fa9-b40d-55bc8657a357"}}}}, {"uuid": "c1427e78-5470-44e6-90f6-405b0dcda489", "name": "", "x": 38.65411176650942, "y": -122.48165516473325, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ad24f98d-f022-4e62-b80b-426052810759", "name": "p1rdt5563", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c1427e78-5470-44e6-90f6-405b0dcda489"}}}}, {"uuid": "ad5db67d-1964-4568-ad89-8f27ba79aa8d", "name": "", "x": 38.65399305368811, "y": -122.48234388532953, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c94489ed-4399-4dab-bab6-02b79f240f63", "name": "p1rdt5557-p1rdt5563x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ad5db67d-1964-4568-ad89-8f27ba79aa8d"}}}}, {"uuid": "b159b55d-cc9f-46ad-bf19-5d08b45496f4", "name": "", "x": 38.65409795953588, "y": -122.48170621590174, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fbc31b75-f942-4bae-8712-f1666d8b7f26", "name": "p1rdt5557-p1rdt5563xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b159b55d-cc9f-46ad-bf19-5d08b45496f4"}}}}, {"uuid": "cbcd009a-0c20-4d15-a018-6b45b447e5a2", "name": "", "x": 38.65386072697981, "y": -122.48298842075683, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "efe7243f-340b-4114-be7c-f7494e78384f", "name": "p1rdt5557-p1rdt5565xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cbcd009a-0c20-4d15-a018-6b45b447e5a2"}}}}, {"uuid": "0a21d5f6-b987-4af0-8cad-052a586d9aaf", "name": "", "x": 38.6540547104338, "y": -122.48228339829146, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bfe92e2e-285d-4c58-8e0b-a462dd73fa41", "name": "p1rdt5557-p1rdt5565x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a21d5f6-b987-4af0-8cad-052a586d9aaf"}}}}, {"uuid": "53b7a282-efd7-49b9-8b4c-e3660d062d2f", "name": "", "x": 38.653744336845875, "y": -122.48342339339821, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8bd0860f-2b3e-4c90-a571-cfc6aa649e5b", "name": "p1rdt5561-p1rdt5565x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "53b7a282-efd7-49b9-8b4c-e3660d062d2f"}}}}, {"uuid": "83fe7a48-cf07-4fea-aee2-6f82ef002e17", "name": "", "x": 38.653922384064785, "y": -122.48292793438009, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bebca5d7-2d4f-4655-a965-9faafd7a8125", "name": "p1rdt5561-p1rdt5565xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "83fe7a48-cf07-4fea-aee2-6f82ef002e17"}}}}, {"uuid": "e16a0510-15af-4338-ad06-536625606dae", "name": "", "x": 38.653656874338274, "y": -122.48382172207613, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "27ab530f-a58e-4113-80f6-63f768910204", "name": "p1rdt5551-p1rdt5561x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e16a0510-15af-4338-ad06-536625606dae"}}}}, {"uuid": "4d8bd976-82f1-4fab-984f-87546cf80006", "name": "", "x": 38.65368267949884, "y": -122.4834838792017, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bf97a458-469e-4609-bb33-97454e7c2b68", "name": "p1rdt5551-p1rdt5561xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d8bd976-82f1-4fab-984f-87546cf80006"}}}}, {"uuid": "0d7f3c2b-6d04-41bd-b92d-4a2665f338a3", "name": "", "x": 38.65357363505309, "y": -122.48418848997771, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3d447cf8-7b2b-45f1-8084-6fe4897e1853", "name": "p1rdt5548-p1rdt5551x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0d7f3c2b-6d04-41bd-b92d-4a2665f338a3"}}}}, {"uuid": "bf13386c-86ca-40dc-8ce9-f0367315b4ae", "name": "", "x": 38.65359832142837, "y": -122.48384598170813, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5ec70f12-a676-48cd-b626-34f8d7f6a5bf", "name": "p1rdt5548-p1rdt5551xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bf13386c-86ca-40dc-8ce9-f0367315b4ae"}}}}, {"uuid": "58902d6a-effa-4407-ade5-fc151647b853", "name": "", "x": 38.65344193779202, "y": -122.48465054385285, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "10f43169-4b4b-4dbe-8f09-af72d427d6c7", "name": "p1rdt5548-p1rdt5566xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "58902d6a-effa-4407-ade5-fc151647b853"}}}}, {"uuid": "fa35428d-ad2e-4833-92af-155777d08869", "name": "", "x": 38.65355345327659, "y": -122.48411429646117, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "23163dba-070c-435c-bb90-77be7ded002a", "name": "p1rdt5548-p1rdt5566x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa35428d-ad2e-4833-92af-155777d08869"}}}}, {"uuid": "62505c49-18d7-4dc7-88a2-27afcb42e823", "name": "", "x": 38.65349305461597, "y": -122.48469671958328, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bf619f04-1fa5-4be7-8a76-669b79436d3e", "name": "p1rdt5566-p1rdt5574xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "62505c49-18d7-4dc7-88a2-27afcb42e823"}}}}, {"uuid": "d3ac96ef-09fb-4bae-b143-3a065d9d9ad1", "name": "", "x": 38.65351374951022, "y": -122.48468872832316, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c264e6de-a898-421d-a2fe-ce6548aa477e", "name": "p1rdt5566-p1rdt5574x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d3ac96ef-09fb-4bae-b143-3a065d9d9ad1"}}}}, {"uuid": "06702de2-f8c8-4589-8236-bca704fa692d", "name": "", "x": 38.6521229408726, "y": -122.4867812786121, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "17b633c6-214d-4428-bded-df737f50ffb6", "name": "p1rdt8138", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "06702de2-f8c8-4589-8236-bca704fa692d"}}}}, {"uuid": "0173173b-eac5-4e26-8f41-c21afd87760e", "name": "", "x": 38.65212339039547, "y": -122.48678923108443, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2c8fd701-7842-49c1-b630-7ae1ad49739f", "name": "p1rdt5574-p1rdt8138x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0173173b-eac5-4e26-8f41-c21afd87760e"}}}}, {"uuid": "7596258b-68d1-4f85-b881-4661a9159a6c", "name": "", "x": 38.6534675320259, "y": -122.48473979533868, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e9906676-e9b9-4d51-b1c2-a6b6fe187faa", "name": "p1rdt5574", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7596258b-68d1-4f85-b881-4661a9159a6c"}}}}, {"uuid": "2f74bd6e-72a9-42da-a509-e0390ecfbf81", "name": "", "x": 38.64755444307129, "y": -122.50915596024865, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "63b2f1e6-5e15-4433-85ee-ff7bb7218b96", "name": "p1rdt6488", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2f74bd6e-72a9-42da-a509-e0390ecfbf81"}}}}, {"uuid": "0bbf498a-e4cc-40d6-a250-682263afe9bd", "name": "", "x": 38.647519963483695, "y": -122.50475738860712, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "548ba541-a511-486c-876c-c841a6e482af", "name": "p1rdt6488-p1rdt8138x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0bbf498a-e4cc-40d6-a250-682263afe9bd"}}}}, {"uuid": "e0bc28a4-d366-4769-b729-d481f566e45b", "name": "", "x": 38.653569957917405, "y": -122.48377667700575, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a9dec144-ef2e-44fe-990a-c9d70b740410", "name": "p1rdt5551lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e0bc28a4-d366-4769-b729-d481f566e45b"}}}}, {"uuid": "0edb9ce5-61b9-441c-8a5a-d23c20926863", "name": "", "x": 38.653349320804885, "y": -122.48361706572747, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "82988650-787d-41de-bca7-4f3c08ccad15", "name": "p1rlv11506", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0edb9ce5-61b9-441c-8a5a-d23c20926863"}}}}, {"uuid": "a749a880-49d7-464e-abad-60ef90fb20cf", "name": "", "x": 38.65393253922449, "y": -122.48302660355507, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "60dc1291-a843-4abf-bfc6-ff8afc8c0b98", "name": "p1rdt5565lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a749a880-49d7-464e-abad-60ef90fb20cf"}}}}, {"uuid": "edd8090c-62f3-41ba-b6c3-d35d218dc4e9", "name": "", "x": 38.65344458882935, "y": -122.48274295264503, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "176b348f-9ecf-4a82-bdf9-f2e5d5a07af7", "name": "p1rlv11522", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "edd8090c-62f3-41ba-b6c3-d35d218dc4e9"}}}}, {"uuid": "f15e74bc-cd3f-4502-bdbc-ac249f73eea8", "name": "", "x": 38.65413728795049, "y": -122.4816120875077, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0a150dd3-61a4-4df9-90e2-6c72f80af819", "name": "p1rdt5563lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f15e74bc-cd3f-4502-bdbc-ac249f73eea8"}}}}, {"uuid": "4ba1e7ab-c731-42a2-b1cf-1a4a3eee3337", "name": "", "x": 38.65368296548394, "y": -122.48162646334242, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "22054033-4e69-41b0-b321-a4d086d20574", "name": "p1rlv11520", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ba1e7ab-c731-42a2-b1cf-1a4a3eee3337"}}}}, {"uuid": "2721271a-309e-4478-a9f3-411791dd008f", "name": "", "x": 38.707239856986014, "y": -122.42485436421835, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c5fd6466-e740-4f06-a842-798195d62154", "name": "p1rdt252lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2721271a-309e-4478-a9f3-411791dd008f"}}}}, {"uuid": "8c301039-3b06-4026-9cfd-61173d74a637", "name": "", "x": 38.70723070261674, "y": -122.4249071150479, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a23f97bc-e7ef-4f64-9e64-314f4a4e17d8", "name": "p1rlv440", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8c301039-3b06-4026-9cfd-61173d74a637"}}}}, {"uuid": "beb8a8dd-d1ae-4c46-a0b8-9164b1204cd1", "name": "", "x": 38.65363370971865, "y": -122.48373653900416, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "514ad102-b590-4ad8-a258-2b6fa8dcbeb1", "name": "p1rdt5551-p1rdt5568x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "beb8a8dd-d1ae-4c46-a0b8-9164b1204cd1"}}}}, {"uuid": "5fd03be4-748d-4158-a92d-24b0cc0a9305", "name": "", "x": 38.65350635684874, "y": -122.48421628994025, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "25ee6008-ddbc-4e7b-8a57-ff38c16368a2", "name": "p1rdt5548-p1rdt5577x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5fd03be4-748d-4158-a92d-24b0cc0a9305"}}}}, {"uuid": "bf563631-9bac-4a2c-9536-752dae925812", "name": "", "x": 38.65213674275478, "y": -122.48364605819339, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c1c8b424-4509-4fd2-93e2-4fd54f6cf49a", "name": "p1rdt5577", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bf563631-9bac-4a2c-9536-752dae925812"}}}}, {"uuid": "406f41ee-91ce-4a71-849a-80eed4ccd2c4", "name": "", "x": 38.65403765024386, "y": -122.48233644072755, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cca8918c-30e6-4619-a5e0-8c0d3451f9c4", "name": "p1rdt5557", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "406f41ee-91ce-4a71-849a-80eed4ccd2c4"}}}}, {"uuid": "bbda2575-698a-42f3-b5bf-3a83b99b842a", "name": "", "x": 38.65390532358046, "y": -122.48298097656864, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b5e479d3-aae0-47b8-b707-bad1191df1e7", "name": "p1rdt5565", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bbda2575-698a-42f3-b5bf-3a83b99b842a"}}}}, {"uuid": "c0e900d1-a01a-4a5a-9d85-1a6d12778a63", "name": "", "x": 38.65372727613462, "y": -122.48347643534002, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "756f6cd8-301b-4fac-b414-d72853616c6e", "name": "p1rdt5561", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c0e900d1-a01a-4a5a-9d85-1a6d12778a63"}}}}, {"uuid": "ddd5810d-928e-4fa9-96db-426ae8d4092e", "name": "", "x": 38.653615927095316, "y": -122.48379127781236, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5f7fed4f-197e-4a79-97e5-df595377736b", "name": "p1rdt5551", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ddd5810d-928e-4fa9-96db-426ae8d4092e"}}}}, {"uuid": "99b54ad7-1ddb-4d8c-8305-c45ad70177b3", "name": "", "x": 38.653529895117565, "y": -122.48416522717811, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6bf1b63d-fbce-42f8-9948-2e09bfa67409", "name": "p1rdt5548", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "99b54ad7-1ddb-4d8c-8305-c45ad70177b3"}}}}, {"uuid": "25286f23-9994-4df7-a510-04d00e26e939", "name": "", "x": 38.65348653464999, "y": -122.48464310081867, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "9fed9557-b170-4817-8bd8-efc3b9f7c982", "name": "p1rdt5566", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "25286f23-9994-4df7-a510-04d00e26e939"}}}}, {"uuid": "1f82ec4b-389f-44b2-8e92-0331097de9d4", "name": "", "x": 38.65857449295584, "y": -122.51047390361627, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "16ace27f-f5fa-4fd1-840e-8cae55dbe1b2", "name": "p1rdt383-p1rdt7300x_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1f82ec4b-389f-44b2-8e92-0331097de9d4"}}}}, {"uuid": "11d5fb2d-a11f-4cca-a32d-a54a006ec224", "name": "", "x": 38.755774152251824, "y": -122.36924141377668, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e6b5c947-b0c5-4e20-bd74-bf847bdacd30", "name": "p1rdt181_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "11d5fb2d-a11f-4cca-a32d-a54a006ec224"}}}}, {"uuid": "a94365ec-ba7e-41ad-9b88-27ea9076b835", "name": "", "x": 38.76763103931847, "y": -122.38059245720176, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "99615f32-0614-4c23-a1e1-b3e8e5688cce", "name": "p1rdt66", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a94365ec-ba7e-41ad-9b88-27ea9076b835"}}}}, {"uuid": "8e2b886e-e1fc-41ea-a1e8-76febb13f1e2", "name": "", "x": 38.73066670610679, "y": -122.39985796643494, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "71abd5f1-ca61-4754-a2ef-7b5d4e635f99", "name": "p1rdt181-p1rdt297x_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8e2b886e-e1fc-41ea-a1e8-76febb13f1e2"}}}}, {"uuid": "4d02be35-fcba-456e-b90e-38db765a0ac1", "name": "", "x": 38.73098682493839, "y": -122.41321244241928, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b0fad7ee-b65c-460c-94ca-fe9546a5b140", "name": "p1rdt270-p1rdt298x_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4d02be35-fcba-456e-b90e-38db765a0ac1"}}}}, {"uuid": "639ab63c-d85d-49e0-bfb2-74b043b6dcba", "name": "", "x": 38.68766311446792, "y": -122.34290029588801, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b8064f1d-11b7-4913-8344-175c1388be3e", "name": "p1rdt16604-p1rdt257x_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "639ab63c-d85d-49e0-bfb2-74b043b6dcba"}}}}, {"uuid": "d63106f2-69d0-425e-9c68-7a00109bd753", "name": "", "x": 38.6006266312945, "y": -122.52427556411426, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e2131350-dc34-4d8d-8c9f-c29e25bc654c", "name": "p1rdt7711", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d63106f2-69d0-425e-9c68-7a00109bd753"}}}}, {"uuid": "15ce6336-bc93-4d4a-8034-cf23d75b7464", "name": "", "x": 38.60058489010104, "y": -122.52426789727744, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "64b60527-0853-4973-8d7a-78ba5e377799", "name": "p1rdt7711lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "15ce6336-bc93-4d4a-8034-cf23d75b7464"}}}}, {"uuid": "b247caad-f974-4017-a99d-5bfa5bf2b928", "name": "", "x": 38.600468680548644, "y": -122.5242248045325, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3ed6276c-a57b-40be-a1f1-34aaaba0ac28", "name": "p1rlv16411", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b247caad-f974-4017-a99d-5bfa5bf2b928"}}}}, {"uuid": "a07a22f5-d840-47dd-9319-457197a96756", "name": "", "x": 38.60059554402563, "y": -122.52439622804972, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e0a92e79-0ca2-4a10-9050-9e8d7442b019", "name": "p1rlv20414", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a07a22f5-d840-47dd-9319-457197a96756"}}}}, {"uuid": "6eedbed5-071e-429f-9cb3-c1cf4e13a452", "name": "", "x": 38.59743372341483, "y": -122.52848624702995, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "439728c5-fee5-4dfa-9894-261ba6c40e95", "name": "p1rdt8473lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6eedbed5-071e-429f-9cb3-c1cf4e13a452"}}}}, {"uuid": "8f49bd92-9100-4688-a6c3-8c7dab784aa0", "name": "", "x": 38.59755648297391, "y": -122.52834367013348, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3c1eac45-623a-4f0a-874d-a4b56a8e2ea7", "name": "p1rlv18169", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "8f49bd92-9100-4688-a6c3-8c7dab784aa0"}}}}, {"uuid": "c750bbe3-7c46-4b17-8dda-052506550e67", "name": "", "x": 38.59726926605651, "y": -122.52863263826859, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "949f4cce-f321-4bf0-830b-489edc9964c7", "name": "p1rlv18194", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c750bbe3-7c46-4b17-8dda-052506550e67"}}}}, {"uuid": "c7fc9e30-46b9-4818-b666-3885d4c69c23", "name": "", "x": 38.5973486590682, "y": -122.53115453060339, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "35f6f747-811d-4fe2-a9c7-991248572c74", "name": "p1rdt6028lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c7fc9e30-46b9-4818-b666-3885d4c69c23"}}}}, {"uuid": "d612deb0-ae01-4e0e-8f3c-4dc7320ec9aa", "name": "", "x": 38.597359644970844, "y": -122.53094024225281, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "72f659b6-d302-4887-a2f6-1a477ad3324c", "name": "p1rlv12518", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d612deb0-ae01-4e0e-8f3c-4dc7320ec9aa"}}}}, {"uuid": "f82d5b04-ca0c-4334-a89a-1e8dcc3def3c", "name": "", "x": 38.597740803009394, "y": -122.53160381152783, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f9660b80-0fce-4be4-b541-743d5811133c", "name": "p1rlv12528", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f82d5b04-ca0c-4334-a89a-1e8dcc3def3c"}}}}, {"uuid": "0d020d98-a846-403c-9afb-ee0db1c7029d", "name": "", "x": 38.59730635717321, "y": -122.53113580939358, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8796d817-aad6-4d22-b3d4-baf8a686c9df", "name": "p1rlv12534", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0d020d98-a846-403c-9afb-ee0db1c7029d"}}}}, {"uuid": "7e1a9607-6da1-4730-9899-d1a9821d629a", "name": "", "x": 38.597059503153865, "y": -122.53096119189571, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e89452f3-ce44-46d3-a259-f66044e01c2c", "name": "p1rlv12536", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7e1a9607-6da1-4730-9899-d1a9821d629a"}}}}, {"uuid": "64714c99-eb77-45de-8558-c4ccb0182909", "name": "", "x": 38.598068610661386, "y": -122.54952501293569, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ddf38626-1223-429f-a903-98f1c975020b", "name": "p1rdt9478lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "64714c99-eb77-45de-8558-c4ccb0182909"}}}}, {"uuid": "f8becd39-60a8-4e1e-9c22-bb224d6ad808", "name": "", "x": 38.59809415769325, "y": -122.54948199323535, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cebe1b53-cca6-4bd4-a9f0-616ffb9750b3", "name": "p1rlv20501", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f8becd39-60a8-4e1e-9c22-bb224d6ad808"}}}}, {"uuid": "eba7b3a6-8113-470f-a84e-d5f0ed18ecb5", "name": "", "x": 38.59772028985937, "y": -122.55034252722092, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3e2630e1-a215-4740-9327-fa004e89863d", "name": "p1rdt6232lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "eba7b3a6-8113-470f-a84e-d5f0ed18ecb5"}}}}, {"uuid": "6d3aa3aa-641b-4303-8721-8f50561f013f", "name": "", "x": 38.59770645245217, "y": -122.5503935254409, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "df3aae83-f4b0-4db2-9301-dff1664ac23e", "name": "p1rlv12985", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6d3aa3aa-641b-4303-8721-8f50561f013f"}}}}, {"uuid": "abda40da-fda1-41de-a3fa-a0c7ca091e4f", "name": "", "x": 38.59805477361372, "y": -122.54957601155624, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c49b6e87-5834-4e7e-a64c-b4ec0f7d4995", "name": "p1rdt9478", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "abda40da-fda1-41de-a3fa-a0c7ca091e4f"}}}}, {"uuid": "7465d552-f9fd-4c18-bbcb-046e2214089f", "name": "", "x": 38.59774583719626, "y": -122.55029950801654, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b59ad93a-cca2-4a77-8515-a645ddd2a320", "name": "p1rdt6232", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7465d552-f9fd-4c18-bbcb-046e2214089f"}}}}, {"uuid": "a45aed2c-9785-4267-b6c9-93de8a2eb205", "name": "", "x": 38.59739040278303, "y": -122.53116220049235, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e39cb1db-d6a6-4b6c-bc73-920e0c34c292", "name": "p1rdt6028", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a45aed2c-9785-4267-b6c9-93de8a2eb205"}}}}, {"uuid": "47744c39-d0fa-4c6b-8dd3-2d10ae71edc2", "name": "", "x": 38.602431647117115, "y": -122.53503011701754, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f77960bf-f017-400c-b505-16e7c2e90fe7", "name": "p1rdt6028_b1_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "47744c39-d0fa-4c6b-8dd3-2d10ae71edc2"}}}}, {"uuid": "73fddd2a-9c61-4c25-bfc8-9b3588a86e04", "name": "", "x": 38.597391979534734, "y": -122.52847857868831, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b3a83211-0829-4e2c-b618-3f1fcaba3e87", "name": "p1rdt8473", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "73fddd2a-9c61-4c25-bfc8-9b3588a86e04"}}}}, {"uuid": "d47488e2-6469-4439-a236-085f77265a79", "name": "", "x": 38.59407749157057, "y": -122.52505662658886, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c330731a-fd2c-40c7-8fce-94f7e17cf6d9", "name": "p1rdt8493lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d47488e2-6469-4439-a236-085f77265a79"}}}}, {"uuid": "c5d6d872-0cb7-44a4-8b2a-1680dd82e11e", "name": "", "x": 38.594091817303486, "y": -122.52510740253169, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ead37cb8-af1e-4a46-9466-6ff298b7f8b7", "name": "p1rlv18201", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "57c179d5-1c5f-4039-a510-56a9f9efc5ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "e9109c8c-670b-4b9d-9777-b980f4791a6b"}}}], "nominal_voltage": {"value": 0.27712812921102037, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c5d6d872-0cb7-44a4-8b2a-1680dd82e11e"}}}}, {"uuid": "d543b5e5-21eb-4d18-83f8-f17b77f46c83", "name": "", "x": 38.59405153241799, "y": -122.52501401155037, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cfb41891-7063-44b8-9286-1fe763e49924", "name": "p1rdt8493", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d543b5e5-21eb-4d18-83f8-f17b77f46c83"}}}}, {"uuid": "e2336c83-39fe-4b64-9b84-2eb2f4408be8", "name": "", "x": 38.6026030514407, "y": -122.53507494861152, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "409a29cf-ddd5-4031-92ca-db6cd2410704", "name": "p1rdt6028_b2_1", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e2336c83-39fe-4b64-9b84-2eb2f4408be8"}}}}, {"uuid": "84a1a7b9-2f6d-432e-8a26-762b186fd77d", "name": "", "x": 38.67296456591668, "y": -122.57311952323086, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0921e58d-1ada-4556-8b01-8f22d3bf4ee2", "name": "p1rdt93lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "84a1a7b9-2f6d-432e-8a26-762b186fd77d"}}}}, {"uuid": "19391878-f7ac-418c-985a-d1d03bec6f38", "name": "", "x": 38.67288108818913, "y": -122.57387827884625, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3df778b4-e60b-4e17-b24b-67742d090f42", "name": "p1rlv183", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "19391878-f7ac-418c-985a-d1d03bec6f38"}}}}, {"uuid": "08de448b-f269-408e-8555-53810fe0aea3", "name": "", "x": 38.67284336560701, "y": -122.57341867755696, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d663fcdc-6c67-4bc9-99ed-12439f75804f", "name": "p1rlv204", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "08de448b-f269-408e-8555-53810fe0aea3"}}}}, {"uuid": "afc1a4c5-298c-454e-94d8-c72167c86521", "name": "", "x": 38.672896260917035, "y": -122.57309648596055, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2be21180-bfa8-4cd1-a3c5-68602896d657", "name": "p1rdm198", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "afc1a4c5-298c-454e-94d8-c72167c86521"}}}}, {"uuid": "f2445300-d709-40be-9352-addfc8d3546e", "name": "", "x": 38.67255503590974, "y": -122.57343188427429, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "90aa0d14-285a-4468-bbde-8d76f65b1780", "name": "p1rlv206", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f2445300-d709-40be-9352-addfc8d3546e"}}}}, {"uuid": "38a53f09-a685-40f7-b20c-a7170caea4fb", "name": "", "x": 38.67306781717814, "y": -122.57318743231879, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6a70fd02-3816-451f-a509-2ad767068eb4", "name": "p1rdm199", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "38a53f09-a685-40f7-b20c-a7170caea4fb"}}}}, {"uuid": "0c9426a0-9096-48e9-90ab-ad9746ad6f6f", "name": "", "x": 38.67309761817342, "y": -122.5739459691624, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6627102c-4524-4e69-bb4d-5b93226df412", "name": "p1rlv207", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0c9426a0-9096-48e9-90ab-ad9746ad6f6f"}}}}, {"uuid": "6210c740-6072-4fd5-8cb2-494c338084d5", "name": "", "x": 38.673202949412286, "y": -122.57317513422406, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6065e92f-dd89-4aeb-94af-173d81a49df1", "name": "p1rdm196", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6210c740-6072-4fd5-8cb2-494c338084d5"}}}}, {"uuid": "383df165-d455-44d1-aaa7-d9d026fa4bf3", "name": "", "x": 38.67319695527533, "y": -122.57400285874593, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "42ca8327-5dcc-415a-820c-ef6ec038b3d8", "name": "p1rlv184", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "383df165-d455-44d1-aaa7-d9d026fa4bf3"}}}}, {"uuid": "0fb5e2e8-91ff-4337-ae5c-5874c4a5a5b4", "name": "", "x": 38.6716242440999, "y": -122.57350240564409, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ef6be92d-5d1b-40e2-a2c2-9d0c1f0bf596", "name": "p1rdt99lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0fb5e2e8-91ff-4337-ae5c-5874c4a5a5b4"}}}}, {"uuid": "121accee-3c5d-4d8e-afbd-aa488401ee1b", "name": "", "x": 38.67172785280663, "y": -122.57395408806927, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "33b6400e-c84e-43cf-b254-99f946e5a308", "name": "p1rlv190", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "121accee-3c5d-4d8e-afbd-aa488401ee1b"}}}}, {"uuid": "9ab562c3-fcf0-48cb-91a8-6a775a66e30e", "name": "", "x": 38.671562374281784, "y": -122.57305842624851, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "de2366e4-30da-429a-82b9-c0ef27eeab47", "name": "p1rlv202", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "9ab562c3-fcf0-48cb-91a8-6a775a66e30e"}}}}, {"uuid": "371eadd3-a103-436e-b114-f0c24aaa1d57", "name": "", "x": 38.674085731551074, "y": -122.57304573384614, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "1277a701-9fbd-4853-a809-962475e016c4", "name": "p1rdt101lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "371eadd3-a103-436e-b114-f0c24aaa1d57"}}}}, {"uuid": "11a58949-2b98-49be-b558-d21e2a7bea41", "name": "", "x": 38.674164000252716, "y": -122.57229574382116, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "84223c1b-69e4-4ebc-8274-8706bb412780", "name": "p1rlv193", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "11a58949-2b98-49be-b558-d21e2a7bea41"}}}}, {"uuid": "3042c514-d9a7-4cbf-b292-08e4f7e3bf5f", "name": "", "x": 38.673326264900375, "y": -122.57317042703883, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3aa8d6f2-8d84-42d6-8e7b-89e3b1efa03c", "name": "p1rdt108lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3042c514-d9a7-4cbf-b292-08e4f7e3bf5f"}}}}, {"uuid": "fba9d52a-56da-4743-9f43-d8e41e614e35", "name": "", "x": 38.673338794652196, "y": -122.57335825878279, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a982feac-5730-4fe0-a1b8-25c06b36e3b0", "name": "p1rlv212", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fba9d52a-56da-4743-9f43-d8e41e614e35"}}}}, {"uuid": "6f53652c-c937-430f-839f-ab69e81b2b63", "name": "", "x": 38.661367233687706, "y": -122.56984548041399, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "448cc5e0-391f-4a6b-8199-25cef4593edf", "name": "p1rdt6121lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6f53652c-c937-430f-839f-ab69e81b2b63"}}}}, {"uuid": "489d0901-4beb-4fa1-98a8-56a8df5765df", "name": "", "x": 38.66161605427373, "y": -122.56888775894382, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "163c3824-6847-4b94-9e81-08f15f4667a1", "name": "p1rlv12687", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "489d0901-4beb-4fa1-98a8-56a8df5765df"}}}}, {"uuid": "18b06d68-ca94-4d75-b53f-e26986e76248", "name": "", "x": 38.66221308963423, "y": -122.56844471302269, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5e81ba94-5857-42e4-aeee-58542cef0fb6", "name": "p1rdt6123lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "18b06d68-ca94-4d75-b53f-e26986e76248"}}}}, {"uuid": "5ab40600-e462-49b4-a6e1-97fcebd2e9c8", "name": "", "x": 38.662187146256294, "y": -122.5684020420726, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ff16aad0-98c1-4563-a844-e0ce909c1a79", "name": "p1rlv12713", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5ab40600-e462-49b4-a6e1-97fcebd2e9c8"}}}}, {"uuid": "48892e13-368b-44ee-824c-fa7c114949e5", "name": "", "x": 38.666474403379304, "y": -122.59876007752939, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8428de0e-4b06-4f19-bffb-5fed32f96f67", "name": "p1rdt8017lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "48892e13-368b-44ee-824c-fa7c114949e5"}}}}, {"uuid": "4417ff6d-d2ea-4fe9-88cb-de12f1a6ab25", "name": "", "x": 38.666431086206416, "y": -122.59829258598047, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b53edd15-5a3e-4b7a-97c4-046582bb4801", "name": "p1rlv17006", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4417ff6d-d2ea-4fe9-88cb-de12f1a6ab25"}}}}, {"uuid": "308b380d-d41b-45f3-96de-9e617604886e", "name": "", "x": 38.66353413238862, "y": -122.60568928818653, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a367e687-b29a-44b4-a943-7b94762e549e", "name": "p1rdt8043lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "308b380d-d41b-45f3-96de-9e617604886e"}}}}, {"uuid": "08f15de6-260e-419d-911e-b628e755ff37", "name": "", "x": 38.6635082025271, "y": -122.60564660289965, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8ff9eb4c-2523-48e0-8490-619d26b9cca4", "name": "p1rlv17103", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "08f15de6-260e-419d-911e-b628e755ff37"}}}}, {"uuid": "3f5eea31-80ca-4830-9a4c-66869b9db1a5", "name": "", "x": 38.656285239065134, "y": -122.61480721656375, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8bb025c5-31eb-4771-b433-e1dcad03b3ed", "name": "p1rdt8065lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3f5eea31-80ca-4830-9a4c-66869b9db1a5"}}}}, {"uuid": "c7d84cbf-8e4a-40fa-948c-a37206aa3f12", "name": "", "x": 38.65636014038154, "y": -122.61479929639421, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a3c6c52e-cf93-467a-a303-94b96b33a3da", "name": "p1rlv17155", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c7d84cbf-8e4a-40fa-948c-a37206aa3f12"}}}}, {"uuid": "57105b01-9e4d-457c-a82e-90b19eb89a1a", "name": "", "x": 38.65653706419615, "y": -122.61653379624518, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "62e77e46-bf33-474f-907b-81d36aae8975", "name": "p1rdm17752", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "57105b01-9e4d-457c-a82e-90b19eb89a1a"}}}}, {"uuid": "59295e4b-87ad-415c-8961-0244dffcbade", "name": "", "x": 38.656142018437656, "y": -122.61698412819987, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "041caa30-2985-44ca-8013-e11a9bda7dff", "name": "p1rlv17164", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "59295e4b-87ad-415c-8961-0244dffcbade"}}}}, {"uuid": "73d19644-a33b-400d-bc6c-0b09086220d9", "name": "", "x": 38.65646182364152, "y": -122.61643827928047, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dd01eed6-0e70-42e7-ac29-4bfd2f70366a", "name": "p1rdt8068lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "73d19644-a33b-400d-bc6c-0b09086220d9"}}}}, {"uuid": "e8387e72-4704-4ccd-ba30-31f1bae60656", "name": "", "x": 38.6564643300682, "y": -122.61633880273914, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "46b5c5bc-6738-4520-b98c-32bd43f4c91c", "name": "p1rdm17753", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e8387e72-4704-4ccd-ba30-31f1bae60656"}}}}, {"uuid": "04a61433-ab27-4c19-8d09-b9a8f24e0620", "name": "", "x": 38.65583419030237, "y": -122.6165490366375, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5768eaca-abe3-4347-af78-02b50ec6f2a9", "name": "p1rlv17199", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "04a61433-ab27-4c19-8d09-b9a8f24e0620"}}}}, {"uuid": "e26f0031-1622-4dc5-844f-d31e2652eff3", "name": "", "x": 38.656487161757404, "y": -122.6159209581833, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d0bcd460-ccf2-42ee-83c6-bada397ab4d6", "name": "p1rdt8070lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e26f0031-1622-4dc5-844f-d31e2652eff3"}}}}, {"uuid": "ddb8eca2-3f6e-48b5-9bd6-8b8c916885cf", "name": "", "x": 38.65609360641926, "y": -122.61596151268897, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2b4e44ab-e644-4e48-b1b2-82dc15d38d17", "name": "p1rlv17167", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ddb8eca2-3f6e-48b5-9bd6-8b8c916885cf"}}}}, {"uuid": "5d80fb83-4c57-405b-be79-fefbfe9f0f29", "name": "", "x": 38.66692113690325, "y": -122.58783715855819, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f21f4e99-8877-4bb0-9956-9240bc6db3d1", "name": "p1rdt8190lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5d80fb83-4c57-405b-be79-fefbfe9f0f29"}}}}, {"uuid": "0ec4963f-c030-40aa-8f4c-bf6e68b00d71", "name": "", "x": 38.66724289358908, "y": -122.58733754347764, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8c9970ae-e914-407d-8222-12c08638a854", "name": "p1rlv17376", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0ec4963f-c030-40aa-8f4c-bf6e68b00d71"}}}}, {"uuid": "d61466da-7b42-4518-90f7-f4815488ce05", "name": "", "x": 38.664369444812806, "y": -122.58690973341812, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d12bf6fb-8dac-4729-bcda-1ee61c63f6e8", "name": "p1rdt8204lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d61466da-7b42-4518-90f7-f4815488ce05"}}}}, {"uuid": "0a451f8e-953d-4a4d-8347-edad82693b2c", "name": "", "x": 38.66416826088575, "y": -122.58688392637725, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dc7fa312-1baf-4f23-925f-a281071183a6", "name": "p1rlv17402", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0a451f8e-953d-4a4d-8347-edad82693b2c"}}}}, {"uuid": "4b26802d-e23c-4468-b2c3-580cea831428", "name": "", "x": 38.6664926486277, "y": -122.58749879976138, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ecf11723-eb6d-423c-ac0c-85fa2d1ba846", "name": "p1rdt8208lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4b26802d-e23c-4468-b2c3-580cea831428"}}}}, {"uuid": "4ac2c5c1-618e-4106-b26e-5c3773bf4c79", "name": "", "x": 38.666718636185976, "y": -122.58689226135496, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f147f7e5-33e8-430b-9822-715e772debb3", "name": "p1rlv17413", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "4ac2c5c1-618e-4106-b26e-5c3773bf4c79"}}}}, {"uuid": "f901d18c-7e76-4de4-83f3-504b150840d2", "name": "", "x": 38.6508349878355, "y": -122.52772270990391, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "f1a593e3-4735-47d2-b893-dd2d07c3c47c", "name": "p1rdt8578lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f901d18c-7e76-4de4-83f3-504b150840d2"}}}}, {"uuid": "fa2bab8c-4741-4c89-a36e-0f401dc5f8f6", "name": "", "x": 38.6509409741122, "y": -122.52789042198899, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "5a28b095-45f5-43ec-983b-c1de596d4cb5", "name": "p1rlv18362", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa2bab8c-4741-4c89-a36e-0f401dc5f8f6"}}}}, {"uuid": "54e5f769-3d1c-4b01-8a58-c3530ce25014", "name": "", "x": 38.65066839894964, "y": -122.52734059189255, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8d1c3d0a-9def-4516-8429-386f1d70f506", "name": "p1rlv18364", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "54e5f769-3d1c-4b01-8a58-c3530ce25014"}}}}, {"uuid": "3d133081-f320-481d-93db-a3b5dcc28d51", "name": "", "x": 38.650824008938194, "y": -122.52793715797524, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "408c825d-17ac-4aea-9fc7-fff420657fc7", "name": "p1rlv18367", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3d133081-f320-481d-93db-a3b5dcc28d51"}}}}, {"uuid": "fa1ac5d2-b7cb-453b-9242-5ea28ea7b3ab", "name": "", "x": 38.647860789632105, "y": -122.5254589040337, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "134bac3d-5b7e-48d7-950e-01e5b7d43852", "name": "p1rdt8583lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "fa1ac5d2-b7cb-453b-9242-5ea28ea7b3ab"}}}}, {"uuid": "d536c44b-825c-4165-812f-b5fa407dad21", "name": "", "x": 38.64817724906055, "y": -122.52638016767358, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "905e171c-13d7-4f8d-b88a-7501b2327d81", "name": "p1rlv18370", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "d536c44b-825c-4165-812f-b5fa407dad21"}}}}, {"uuid": "a6f0e76a-a551-45f5-a544-955ccc0eb60d", "name": "", "x": 38.64706546256806, "y": -122.5262571069094, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a8ba1042-fcfd-47a8-aa0f-8b13618d3212", "name": "p1rdt8584lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "a6f0e76a-a551-45f5-a544-955ccc0eb60d"}}}}, {"uuid": "7891f0b1-efd2-44fb-9612-2be3e5dd1ef6", "name": "", "x": 38.64750833323082, "y": -122.52657595427343, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "58792e8c-3ad9-45bb-ac47-01983cca2a2b", "name": "p1rlv18371", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7891f0b1-efd2-44fb-9612-2be3e5dd1ef6"}}}}, {"uuid": "ee4e0a8b-2d46-4187-a857-a2e71a918ff8", "name": "", "x": 38.66789379909343, "y": -122.62737431712556, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "c8f14e6e-ee96-4ae9-86ba-4a07cf103b65", "name": "p1rdt10491lv", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ee4e0a8b-2d46-4187-a857-a2e71a918ff8"}}}}, {"uuid": "2655db2b-f896-45ca-817d-dba842af8f70", "name": "", "x": 38.66785523664377, "y": -122.62747399595972, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a86348e4-7573-4903-b223-90155579923e", "name": "p1rlv22745", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2655db2b-f896-45ca-817d-dba842af8f70"}}}}, {"uuid": "3acca42a-228d-405c-b242-24b9b408046c", "name": "", "x": 38.66771072023337, "y": -122.6273712914315, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ee8b6bab-9edd-4250-b57b-3a76b432fb54", "name": "p1rdm23269", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3acca42a-228d-405c-b242-24b9b408046c"}}}}, {"uuid": "e82104cd-1fd3-4a40-84ae-355f99fe8c59", "name": "", "x": 38.66773801158078, "y": -122.62745161373962, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "db05b7f0-d2a8-4876-876e-ef0e9b469580", "name": "p1rlv22758", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "5e5ef2ab-cb8c-4775-952c-4b399feeb5bc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "f276cc53-f32d-4fef-a484-058c96f24fc5"}}}], "nominal_voltage": {"value": 0.12008885599144216, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "e82104cd-1fd3-4a40-84ae-355f99fe8c59"}}}}, {"uuid": "5b6968d5-f9b5-4ee7-adba-3b83bc1f93d0", "name": "", "x": 38.656528899791525, "y": -122.61592868327206, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "473520c7-0098-4bc2-a46f-07efd6c3759c", "name": "p1rdt8070", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5b6968d5-f9b5-4ee7-adba-3b83bc1f93d0"}}}}, {"uuid": "7bb0f297-562b-497d-b9ce-36499e5b1011", "name": "", "x": 38.6563269771708, "y": -122.61481494098487, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "862f3566-9443-4b82-8f05-c994581e131a", "name": "p1rdt8065", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "7bb0f297-562b-497d-b9ce-36499e5b1011"}}}}, {"uuid": "5b97a273-c1db-4cad-ba97-ea0ec4645596", "name": "", "x": 38.65650356164319, "y": -122.61644600466717, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "7f5fbb8b-0c32-4aa7-acaf-7ea2b5e56505", "name": "p1rdt8068", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "5b97a273-c1db-4cad-ba97-ea0ec4645596"}}}}, {"uuid": "3e57a0ea-ffba-40e1-804e-eaa3a7897315", "name": "", "x": 38.663548423315845, "y": -122.60574012937602, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "691c1909-3b71-4e07-abf0-95aaabfa23bb", "name": "p1rdt8043", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3e57a0ea-ffba-40e1-804e-eaa3a7897315"}}}}, {"uuid": "ed6aebf5-9450-4578-881d-cae98151a49d", "name": "", "x": 38.65907117917629, "y": -122.61161258790305, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "cbafbe81-1649-4bae-b9af-c4b1757392f0", "name": "p1rdt8043-p1rdt8070x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "ed6aebf5-9450-4578-881d-cae98151a49d"}}}}, {"uuid": "6c8fea95-a7aa-4e43-ab48-30f65042e891", "name": "", "x": 38.66743589391774, "y": -122.62597035336422, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ca19324f-0855-4633-be68-b16c872e196d", "name": "p1rdt10491-p1rdt8043x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6c8fea95-a7aa-4e43-ab48-30f65042e891"}}}}, {"uuid": "99689df4-980e-4bb2-b002-ae9a37ffd539", "name": "", "x": 38.667852061856834, "y": -122.62736658421983, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "4737e613-8cf5-45d7-a3f5-71af051ece4c", "name": "p1rdt10491", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "99689df4-980e-4bb2-b002-ae9a37ffd539"}}}}, {"uuid": "6499ec0f-5e4c-4c55-9d87-b9feec61c306", "name": "", "x": 38.666432664329825, "y": -122.59875236139737, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b6378abd-969e-4ec8-93eb-2cc39cdb18eb", "name": "p1rdt8017", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6499ec0f-5e4c-4c55-9d87-b9feec61c306"}}}}, {"uuid": "f8c35a56-8487-4552-91de-996ae7e93a21", "name": "", "x": 38.665466700320124, "y": -122.60006059980222, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "feda8d99-6fae-4c6e-bf52-f87894687da5", "name": "p1rdt8017-p1rdt8043x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "f8c35a56-8487-4552-91de-996ae7e93a21"}}}}, {"uuid": "b47e2761-7265-4eda-9f5e-916e5198314b", "name": "", "x": 38.67412513347839, "y": -122.57295162842586, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a09cdbca-4e7b-4d9a-b479-515074964171", "name": "p1rdt101-p1rdt8017x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b47e2761-7265-4eda-9f5e-916e5198314b"}}}}, {"uuid": "0d8f64aa-a831-414b-b33d-90920ccc73f2", "name": "", "x": 38.67372843812363, "y": -122.57642531522278, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "b1aeba4b-536e-4067-a7a5-627470ae0711", "name": "p1rdt101-p1rdt8017xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "0d8f64aa-a831-414b-b33d-90920ccc73f2"}}}}, {"uuid": "cb64d0c5-316b-4ef4-9fc4-06dc369727d9", "name": "", "x": 38.6667923442126, "y": -122.59769681955328, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8c1a4365-a594-48be-b138-aa6935c34481", "name": "p1rdt101-p1rdt8017xxx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cb64d0c5-316b-4ef4-9fc4-06dc369727d9"}}}}, {"uuid": "6b0aaced-0cdb-4e3b-9ab8-ec56496f99ba", "name": "", "x": 38.67336800550842, "y": -122.57317812900477, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e61ce952-a643-45aa-a466-8aa15ecceb48", "name": "p1rdt108", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6b0aaced-0cdb-4e3b-9ab8-ec56496f99ba"}}}}, {"uuid": "cc9a67b6-79b9-4193-be24-d3b00a83c29d", "name": "", "x": 38.67409957836356, "y": -122.57299468560076, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2d8e5d83-cd9c-4527-9eef-6219c98dfe93", "name": "p1rdt101", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cc9a67b6-79b9-4193-be24-d3b00a83c29d"}}}}, {"uuid": "cbcc0bc7-f2c6-4318-8fe8-f233849842d7", "name": "", "x": 38.673004812616185, "y": -122.57321304352497, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "a4f100ee-0152-4e27-bf0e-2c7dea1537ad", "name": "p1rdt108-p1rdt93x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "cbcc0bc7-f2c6-4318-8fe8-f233849842d7"}}}}, {"uuid": "80f718dd-80a7-4d45-98b2-65163070d903", "name": "", "x": 38.66653438838322, "y": -122.58750650935949, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "8e2b4d77-2388-4897-86fe-06409fa9d222", "name": "p1rdt8208", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "80f718dd-80a7-4d45-98b2-65163070d903"}}}}, {"uuid": "c15f08e7-d9f7-403e-a6d8-3b883874c9fc", "name": "", "x": 38.6643277050057, "y": -122.58690202438763, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "fa2342e6-2d40-424a-830c-a84af4632b6e", "name": "p1rdt8204", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c15f08e7-d9f7-403e-a6d8-3b883874c9fc"}}}}, {"uuid": "914c9442-7ee2-4f65-83b0-5589227565a3", "name": "", "x": 38.66696287663581, "y": -122.58784486869551, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "0a761aef-a766-40e2-b8d7-e5a918cece18", "name": "p1rdt8190", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "914c9442-7ee2-4f65-83b0-5589227565a3"}}}}, {"uuid": "2b710d2f-ba85-48eb-b045-0a1e53513481", "name": "", "x": 38.66701682299843, "y": -122.58779500809689, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "3b860d5c-43e4-429e-b945-378020e3f926", "name": "p1rdt8190-p1rdt99xx", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2b710d2f-ba85-48eb-b045-0a1e53513481"}}}}, {"uuid": "45f324c1-53a0-4c45-84bb-8247a59540a3", "name": "", "x": 38.67081351738392, "y": -122.57529296188245, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "6be75535-8c32-47ea-bad5-986daaed0921", "name": "p1rdt8190-p1rdt99x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "45f324c1-53a0-4c45-84bb-8247a59540a3"}}}}, {"uuid": "bd0ae6f7-68ed-42de-91dc-6e78b005e83b", "name": "", "x": 38.661326984313604, "y": -122.56975197710662, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "ddf8f344-dcca-418d-850e-745f18d29660", "name": "p1rdt6121-p1rdt6123x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "bd0ae6f7-68ed-42de-91dc-6e78b005e83b"}}}}, {"uuid": "1062a7cd-f594-4e16-9327-1fee2a297714", "name": "", "x": 38.6622273967057, "y": -122.56849554572818, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "17f807ba-6ad6-4fd9-9dd0-2c0bacea5b24", "name": "p1rdt6123", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1062a7cd-f594-4e16-9327-1fee2a297714"}}}}, {"uuid": "b1a6adaf-4169-404d-815c-821d17c42c72", "name": "", "x": 38.64782050495066, "y": -122.52536544340624, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "d0747505-3381-4df0-a86e-3859acac8496", "name": "p1rdt8583-p1rdt8584x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b1a6adaf-4169-404d-815c-821d17c42c72"}}}}, {"uuid": "6fe736f3-597d-4832-a078-7f9462c6089a", "name": "", "x": 38.64710720626507, "y": -122.52626477895555, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2b601580-3091-4d8c-9718-1367c7ed385f", "name": "p1rdt8584", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "6fe736f3-597d-4832-a078-7f9462c6089a"}}}}, {"uuid": "b74c66f5-7370-4363-aadb-c2963556dbbb", "name": "", "x": 38.67166598469829, "y": -122.57351010762986, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "092a9d51-a39c-4c05-905e-93fb1ae96ba2", "name": "p1rdt99", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "b74c66f5-7370-4363-aadb-c2963556dbbb"}}}}, {"uuid": "c251ee2b-6d25-444e-84ed-7a550939f36b", "name": "", "x": 38.671869985546934, "y": -122.57338996774229, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "e3d15ce6-878d-4dd5-bb33-5a0f6c11dded", "name": "p1rdt93-p1rdt99x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c251ee2b-6d25-444e-84ed-7a550939f36b"}}}}, {"uuid": "3c977c81-252d-4ac1-99d0-aac8f9743cbc", "name": "", "x": 38.67299050757224, "y": -122.5731622022605, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "900d49ce-4834-4f99-8d74-a5e9d2f63ea0", "name": "p1rdt93", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "3c977c81-252d-4ac1-99d0-aac8f9743cbc"}}}}, {"uuid": "2bd1ce4a-a2d6-48af-9731-0ffbbac3c303", "name": "", "x": 38.66135292720275, "y": -122.56979464804087, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "2390c014-d418-4d63-8438-529a036487db", "name": "p1rdt6121", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "2bd1ce4a-a2d6-48af-9731-0ffbbac3c303"}}}}, {"uuid": "c7db02d4-5bc2-4f36-97d1-dfc8a8bdabb6", "name": "", "x": 38.66910358694126, "y": -122.57345236501213, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "49c9e6df-3490-4df1-88a0-8a83ca6cdd1e", "name": "p1rdt6121-p1rdt99x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "c7db02d4-5bc2-4f36-97d1-dfc8a8bdabb6"}}}}, {"uuid": "697424df-cd5f-4975-84bb-60f564edf569", "name": "", "x": 38.650793244252796, "y": -122.52771503663553, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "bb866499-9e9c-4394-bd76-d4320ba4934b", "name": "p1rdt8578", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "697424df-cd5f-4975-84bb-60f564edf569"}}}}, {"uuid": "35989896-71ba-4201-91dc-e454d727ee91", "name": "", "x": 38.660311758411375, "y": -122.56710257404733, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "af229e5c-a70f-4354-bddc-4a2698802741", "name": "p1rdt6121-p1rdt8578x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "35989896-71ba-4201-91dc-e454d727ee91"}}}}, {"uuid": "939671ba-5e71-4c33-a5b6-6ae2212229dc", "name": "", "x": 38.64784646411654, "y": -122.52540809020192, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "dbb79e10-21ba-4f04-b8a3-0cf711d26d40", "name": "p1rdt8583", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "939671ba-5e71-4c33-a5b6-6ae2212229dc"}}}}, {"uuid": "1d950e8d-70ee-4f99-a69a-f6c10714f0b3", "name": "", "x": 38.648598745729544, "y": -122.52587175663075, "crs": null, "__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "base"}}}, {"uuid": "975237e9-bd83-4a30-83ab-221eb7f85c65", "name": "p1rdt8578-p1rdt8583x", "substation": null, "feeder": null, "voltage_type": "line-to-ground", "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "base"}}, "voltagelimits": [{"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "a4323061-946b-4d64-85f6-ccc5d5addf7e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "VoltageLimitSet", "serialized_type": "composed_component", "uuid": "af5be9d3-ae35-4b53-ac7e-726d5d3ea6a4"}}}], "nominal_voltage": {"value": 7.199557856794634, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "coordinate": {"__metadata__": {"fields": {"module": "infrasys.location", "type": "Location", "serialized_type": "composed_component", "uuid": "1d950e8d-70ee-4f99-a69a-f6c10714f0b3"}}}}, {"uuid": "614fdcef-422b-4210-b725-39f50e5db0bf", "name": "635840a4-7200-4618-8afc-99b9529d4031_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_voltagesource_equipment", "type": "PhaseVoltageSourceEquipment", "serialized_type": "base"}}, "r0": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Resistance", "serialized_type": "quantity"}}}, "r1": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Resistance", "serialized_type": "quantity"}}}, "x0": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Reactance", "serialized_type": "quantity"}}}, "x1": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Reactance", "serialized_type": "quantity"}}}, "voltage": {"value": 39.838337182448036, "units": "kilovolt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "angle": {"value": 0.0, "units": "degree", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Angle", "serialized_type": "quantity"}}}}, {"uuid": "14c8c055-5866-4494-860e-192d157bb809", "name": "635840a4-7200-4618-8afc-99b9529d4031_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_voltagesource_equipment", "type": "PhaseVoltageSourceEquipment", "serialized_type": "base"}}, "r0": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Resistance", "serialized_type": "quantity"}}}, "r1": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Resistance", "serialized_type": "quantity"}}}, "x0": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Reactance", "serialized_type": "quantity"}}}, "x1": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Reactance", "serialized_type": "quantity"}}}, "voltage": {"value": 39.838337182448036, "units": "kilovolt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "angle": {"value": 120.0, "units": "degree", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Angle", "serialized_type": "quantity"}}}}, {"uuid": "00dfcdee-b9ee-489c-a339-b4615d17c496", "name": "635840a4-7200-4618-8afc-99b9529d4031_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_voltagesource_equipment", "type": "PhaseVoltageSourceEquipment", "serialized_type": "base"}}, "r0": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Resistance", "serialized_type": "quantity"}}}, "r1": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Resistance", "serialized_type": "quantity"}}}, "x0": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Reactance", "serialized_type": "quantity"}}}, "x1": {"value": 1e-05, "units": "ohm", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Reactance", "serialized_type": "quantity"}}}, "voltage": {"value": 39.838337182448036, "units": "kilovolt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "angle": {"value": 240.0, "units": "degree", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Angle", "serialized_type": "quantity"}}}}, {"uuid": "ff5789ac-35ae-461f-8d88-cd7b58b34ab3", "name": "635840a4-7200-4618-8afc-99b9529d4031", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.voltagesource_equipment", "type": "VoltageSourceEquipment", "serialized_type": "base"}}, "sources": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_voltagesource_equipment", "type": "PhaseVoltageSourceEquipment", "serialized_type": "composed_component", "uuid": "614fdcef-422b-4210-b725-39f50e5db0bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_voltagesource_equipment", "type": "PhaseVoltageSourceEquipment", "serialized_type": "composed_component", "uuid": "14c8c055-5866-4494-860e-192d157bb809"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_voltagesource_equipment", "type": "PhaseVoltageSourceEquipment", "serialized_type": "composed_component", "uuid": "00dfcdee-b9ee-489c-a339-b4615d17c496"}}}]}, {"uuid": "267037ac-94da-4162-9484-f2f5d9cab688", "name": "source", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_vsource", "type": "DistributionVoltageSource", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "574ab810-c1b0-4662-8c4d-f32ab6893a36"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.voltagesource_equipment", "type": "VoltageSourceEquipment", "serialized_type": "composed_component", "uuid": "ff5789ac-35ae-461f-8d88-cd7b58b34ab3"}}}}, {"uuid": "e5469e34-b4db-4115-9139-ffc60bb49bbd", "name": "546d6ea1-cd18-4228-8edd-9598526a92df_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.840334051658807, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.3948056193408553, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "67309e73-810a-4c78-8158-ce7710efe7e3", "name": "0de45f54-cece-4e94-844c-81772bee923e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e5469e34-b4db-4115-9139-ffc60bb49bbd"}}}]}, {"uuid": "d8d6bc4a-d96f-43ae-bc69-823255ae76bd", "name": "load_p1rlv10170_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02e86824-b793-4080-9401-c6995a365baf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "67309e73-810a-4c78-8158-ce7710efe7e3"}}}}, {"uuid": "20c0e7c7-8721-449c-8c78-09d4f3da035a", "name": "8ee826d6-19c9-4320-b5fa-c5423073ad16_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.840334051658807, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.3948056193408553, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4b2bfcd5-d8c2-4fcf-a9ef-c821a2fc7a47", "name": "7cd431cb-01ba-4354-b594-83a35144906b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "20c0e7c7-8721-449c-8c78-09d4f3da035a"}}}]}, {"uuid": "4299a3aa-ba1d-4f0a-832e-e4ee9347ae96", "name": "load_p1rlv10170_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02e86824-b793-4080-9401-c6995a365baf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4b2bfcd5-d8c2-4fcf-a9ef-c821a2fc7a47"}}}}, {"uuid": "129db834-e664-434f-8575-b55557c4d16d", "name": "3159695e-34c3-44b2-99ac-8f94ad58ec5f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5675771284059596, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.814222257775612, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1fa7a333-c682-4f9f-b838-214a1d8e9d1c", "name": "1c0a9cd1-4dfa-42e3-9507-6749ffbb8be3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "129db834-e664-434f-8575-b55557c4d16d"}}}]}, {"uuid": "b92a9605-b0ce-432e-98e8-89764b805b42", "name": "load_p1rlv10189_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58f2b2c3-4f6f-4fd2-abb9-42ff665692bd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1fa7a333-c682-4f9f-b838-214a1d8e9d1c"}}}}, {"uuid": "3b57b23f-b611-422d-8dfb-191cdc583f6f", "name": "0d6e89aa-c113-496d-b3b7-27aaa1bc6294_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5675771284059596, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.814222257775612, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5ed83898-2733-4cea-a50f-5d2f64738b3f", "name": "45b095f5-c1e1-4fd2-9c6f-b5c6cbd9d6fe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3b57b23f-b611-422d-8dfb-191cdc583f6f"}}}]}, {"uuid": "18684a60-bdcf-4ecb-b451-206191b5b387", "name": "load_p1rlv10189_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58f2b2c3-4f6f-4fd2-abb9-42ff665692bd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5ed83898-2733-4cea-a50f-5d2f64738b3f"}}}}, {"uuid": "b50974d8-7716-4e1f-a154-58141fe96159", "name": "07638998-4261-4040-9283-9a1ceeb6a17a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2859398622891502, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31064660144885853, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8262d88d-f6d6-4195-84e4-1ef29d502f23", "name": "c5ca30e9-1a76-466f-8aac-a8ac6cca0e2a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b50974d8-7716-4e1f-a154-58141fe96159"}}}]}, {"uuid": "f0b7de95-2441-47ba-b581-d2b2deff0a7c", "name": "load_p1rlv10262_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3317d7c2-2588-426d-91fc-3d765b932da6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8262d88d-f6d6-4195-84e4-1ef29d502f23"}}}}, {"uuid": "8a589d2d-8bb5-4a2d-a783-bae8c6be7f51", "name": "53619472-8b4a-4e99-8f1e-373fe1c283b8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2859398622891502, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31064660144885853, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d1078032-48da-45a9-9514-1bd009f80425", "name": "cae9ace2-76c6-4edb-a648-864e751d71b3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a589d2d-8bb5-4a2d-a783-bae8c6be7f51"}}}]}, {"uuid": "bd031773-5a92-44a8-b655-5ce11b5a4e7b", "name": "load_p1rlv10262_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3317d7c2-2588-426d-91fc-3d765b932da6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d1078032-48da-45a9-9514-1bd009f80425"}}}}, {"uuid": "993432e9-66d3-4fc9-affe-9f6530caeac7", "name": "91274f2d-6b69-4a31-922c-34d0fd405697_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.598111299087247, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3022070914124596, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5c9059e0-2b4a-4ed3-8029-709216e1ff3f", "name": "ee60a67d-83a4-4707-a5ce-a17eb9457a3b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "993432e9-66d3-4fc9-affe-9f6530caeac7"}}}]}, {"uuid": "efed8560-d920-49e0-8ae6-7fa50af9ebef", "name": "load_p1rlv10491_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f7116b9-96c1-42c8-850f-7787f5fd0f96"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5c9059e0-2b4a-4ed3-8029-709216e1ff3f"}}}}, {"uuid": "804be5d0-f940-44d3-87a2-1666ca6bfd99", "name": "8472f830-52fe-4e78-8f35-3650a707dfc3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.598111299087247, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3022070914124596, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e15b851c-dbf3-403b-9ce4-125e3739f110", "name": "5ae5f7ac-f7e3-44c4-81ed-2fd9c6cc7ceb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "804be5d0-f940-44d3-87a2-1666ca6bfd99"}}}]}, {"uuid": "c9f4b35b-fff0-42fe-9c01-70fec1a715f5", "name": "load_p1rlv10491_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f7116b9-96c1-42c8-850f-7787f5fd0f96"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e15b851c-dbf3-403b-9ce4-125e3739f110"}}}}, {"uuid": "2335485c-19cd-4605-9529-64275bc82eb0", "name": "a7ad5af2-a876-40d2-be51-500cc561015e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.388743979084916, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.03502268140121, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "867db88d-63b7-4bee-905f-784adcb5e721", "name": "3ef95a16-ca14-44b8-8a43-40eb5ab8cc7c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2335485c-19cd-4605-9529-64275bc82eb0"}}}]}, {"uuid": "0dc080b9-936f-4c3a-8e91-4be50f2719d3", "name": "load_p1rlv10521_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31f26b28-fc9d-4b3d-b204-cf40f3478c44"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "867db88d-63b7-4bee-905f-784adcb5e721"}}}}, {"uuid": "8418f1e2-1166-44ca-93f2-2f746cabc291", "name": "d8b85703-88cb-4147-9b12-71cc788bb321_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.388743979084916, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.03502268140121, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aa1ebe23-a640-41b4-bf0e-695a31d0e2b9", "name": "b4b52ff8-feab-429c-bfa7-67cfc1e912a9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8418f1e2-1166-44ca-93f2-2f746cabc291"}}}]}, {"uuid": "88b9c328-7f31-4d26-a036-a54f56ce234b", "name": "load_p1rlv10521_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31f26b28-fc9d-4b3d-b204-cf40f3478c44"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aa1ebe23-a640-41b4-bf0e-695a31d0e2b9"}}}}, {"uuid": "8c834a48-84b5-4861-bb74-d75985b72713", "name": "5d0dc6e4-fbab-47f9-8a91-231f6c1cdacb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0052757727111112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4127143879372469, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "88c22e57-29b7-47d0-b622-ffe83d964647", "name": "0ccc4eb5-9755-4d5f-a364-0f965120d933", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8c834a48-84b5-4861-bb74-d75985b72713"}}}]}, {"uuid": "9af6766f-1fd9-4825-a24d-8626cd72f11f", "name": "load_p1rlv10523_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35d47036-a044-4c67-b5b5-0006e2a3b68e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "88c22e57-29b7-47d0-b622-ffe83d964647"}}}}, {"uuid": "8e2f3d41-662e-4980-a1b7-c7fb900caf45", "name": "6647fe10-6588-4164-9eb3-fea25d2a9462_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0052757727111112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4127143879372469, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b8189c3a-08fd-4911-a1b5-f0955e23a3a3", "name": "cb7b10a1-ef90-490e-a741-057dbb9d5a98", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8e2f3d41-662e-4980-a1b7-c7fb900caf45"}}}]}, {"uuid": "5d074c7c-783a-49b5-bbf6-863562eb73a0", "name": "load_p1rlv10523_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35d47036-a044-4c67-b5b5-0006e2a3b68e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b8189c3a-08fd-4911-a1b5-f0955e23a3a3"}}}}, {"uuid": "61dccb8d-ca08-485b-a85d-1ddcd11916ad", "name": "88a2a0b3-fce5-4f48-bfa4-7b1781a741ff_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.346612792133217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8934968317135462, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0338a4f1-fc36-4a79-8794-79a666eb2c08", "name": "fa4c633e-4531-48d1-a321-07ff0c9e763c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "61dccb8d-ca08-485b-a85d-1ddcd11916ad"}}}]}, {"uuid": "92703db3-7c03-43fd-ad1e-f9cfeba4b985", "name": "load_p1rlv10538_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a302271d-4cf3-45ff-9308-b9cf31fbefa3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0338a4f1-fc36-4a79-8794-79a666eb2c08"}}}}, {"uuid": "98bcc0db-9132-4a3c-b610-06c2a350389a", "name": "325c85da-bcf2-4095-a07b-f0d830768108_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.346612792133217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8934968317135462, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ca6b885e-c8f9-4c05-959a-8d15c50227f0", "name": "d67af9d6-ac8e-411c-9161-2fdf6f6679fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "98bcc0db-9132-4a3c-b610-06c2a350389a"}}}]}, {"uuid": "b731739f-fa18-4fad-905c-87443cfce5d5", "name": "load_p1rlv10538_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a302271d-4cf3-45ff-9308-b9cf31fbefa3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ca6b885e-c8f9-4c05-959a-8d15c50227f0"}}}}, {"uuid": "6163aa2a-d4cd-4dfd-ad54-185653ab500b", "name": "561cc921-b931-499a-9b8b-b842a3b37e3b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.732212626630997, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.8695385943463294, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a968d13-c9e7-46a9-91eb-97e0d61a66b4", "name": "561cc921-b931-499a-9b8b-b842a3b37e3b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.732212626630997, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.8695385943463294, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "265d3447-d136-4cd0-89e8-91663f91a7fb", "name": "561cc921-b931-499a-9b8b-b842a3b37e3b_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.732212626630997, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.8695385943463294, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ce4815e4-79ce-4a08-8a1b-ea8a864d4c9b", "name": "1d264e18-a308-48d9-8e38-d4620f923977", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6163aa2a-d4cd-4dfd-ad54-185653ab500b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0a968d13-c9e7-46a9-91eb-97e0d61a66b4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "265d3447-d136-4cd0-89e8-91663f91a7fb"}}}]}, {"uuid": "5a1b9a31-aa33-4417-9163-777f1be8b93c", "name": "load_p1rlv10539", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08331744-08b7-455e-b2ca-284cae95fb06"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ce4815e4-79ce-4a08-8a1b-ea8a864d4c9b"}}}}, {"uuid": "4acb4341-939b-4101-99e7-6eabbbfe10dc", "name": "1b203d67-d092-48e6-9fdd-033bd70091ff_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3798783675992279, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6151141774255103, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "029b3287-e402-41d2-ba35-dc675176b103", "name": "16e47c63-28f8-404d-af33-fb21391635d6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4acb4341-939b-4101-99e7-6eabbbfe10dc"}}}]}, {"uuid": "02684642-c54a-4ad2-85bf-c0eac2537c9d", "name": "load_p1rlv10540_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4829cd2f-7e61-4386-89ce-89d77d5ef5cf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "029b3287-e402-41d2-ba35-dc675176b103"}}}}, {"uuid": "779f5336-f165-4153-927c-a3b56b0c95df", "name": "4c549c39-eef7-4182-949e-97c202c2c5cf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3798783675992279, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6151141774255103, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "36fa9d3b-a675-47fe-8787-cbff3d8847d9", "name": "936c33b0-831b-434b-b429-dc6b6e5a83fe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "779f5336-f165-4153-927c-a3b56b0c95df"}}}]}, {"uuid": "2be448aa-639b-445d-93b9-eff7ac15c311", "name": "load_p1rlv10540_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4829cd2f-7e61-4386-89ce-89d77d5ef5cf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "36fa9d3b-a675-47fe-8787-cbff3d8847d9"}}}}, {"uuid": "872c6067-a8d5-4cf8-9df4-5bffa0ff49f2", "name": "75df7eb9-d32f-44f3-bffe-0c74d23011a3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9115470716545817, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7511996531223851, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b4e1f0ad-c09e-4b3d-91a8-e3e50dcc5fa4", "name": "e09b0864-5e4c-4a3f-bdf7-c34e3e6c2884", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "872c6067-a8d5-4cf8-9df4-5bffa0ff49f2"}}}]}, {"uuid": "447fbe14-d0f5-428a-ae6e-897576c45644", "name": "load_p1rlv10544_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c722b89-fdaf-416f-863e-02b443375ba1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b4e1f0ad-c09e-4b3d-91a8-e3e50dcc5fa4"}}}}, {"uuid": "d8732fcd-8c59-44e7-a017-e1215105f5fa", "name": "72fe6248-d802-4be6-8a03-77d6d027095e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9115470716545817, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7511996531223851, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "443403d0-6584-4bf0-a96a-f0f8755d8610", "name": "8b01779b-6a18-45ef-9644-0f429d6aa12b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d8732fcd-8c59-44e7-a017-e1215105f5fa"}}}]}, {"uuid": "4c73c470-77cf-4169-81a9-d2e62d49ce9a", "name": "load_p1rlv10544_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c722b89-fdaf-416f-863e-02b443375ba1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "443403d0-6584-4bf0-a96a-f0f8755d8610"}}}}, {"uuid": "34640cc1-c224-4d24-b99f-215e00359092", "name": "fc449386-6b31-4ddc-b229-a11c4e93b3fc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6295328634326751, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9988748196040309, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e761bf5d-8dac-40fe-bcc1-784c02d7c9e0", "name": "0d32055b-85ed-43e6-84b0-ea0daf522bd5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "34640cc1-c224-4d24-b99f-215e00359092"}}}]}, {"uuid": "43ed04f3-eff1-4a13-8cf6-62a67d684189", "name": "load_p1rlv10563_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8a10822-398f-441e-a5ca-73303d832183"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e761bf5d-8dac-40fe-bcc1-784c02d7c9e0"}}}}, {"uuid": "2bb093c4-e0e8-4fbe-b20d-2c543a778bb4", "name": "882a7e93-5e51-4249-ad96-1a17e1d7aef4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6295328634326751, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9988748196040309, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ec28bff4-9338-43fc-be62-87fa847f6b55", "name": "1c446171-7668-4308-bfea-5de0daefc0d8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2bb093c4-e0e8-4fbe-b20d-2c543a778bb4"}}}]}, {"uuid": "1f8e033b-4c97-4409-a9ed-ef376cf47405", "name": "load_p1rlv10563_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8a10822-398f-441e-a5ca-73303d832183"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ec28bff4-9338-43fc-be62-87fa847f6b55"}}}}, {"uuid": "1f09440e-cd9a-4892-8523-67a089753aaa", "name": "f3ba15c3-6897-4cf9-b966-1be649810e54_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.140962173014189, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10805830108563602, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d6e738d1-f311-47c7-8ff0-3779b081757e", "name": "0f67960a-e395-41cb-a379-2cf8e66d43c4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1f09440e-cd9a-4892-8523-67a089753aaa"}}}]}, {"uuid": "63d2901e-e1f7-46b7-9244-31a4776e7c0a", "name": "load_p1rlv10573_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94677ede-fd5c-4fbb-bfcd-98cf67b56913"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d6e738d1-f311-47c7-8ff0-3779b081757e"}}}}, {"uuid": "4f079056-6c3e-4ff4-a67f-efe20d6a13e6", "name": "7b2273a6-6447-4fb9-916b-ff2a0a658219_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.140962173014189, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10805830108563602, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0aca7f90-a560-460a-9f18-8ba07af4701d", "name": "3aec8eb6-8ec5-4038-9e34-f5081eae467d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4f079056-6c3e-4ff4-a67f-efe20d6a13e6"}}}]}, {"uuid": "072eddd9-9ee0-4cee-894b-68a9ea4c645b", "name": "load_p1rlv10573_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94677ede-fd5c-4fbb-bfcd-98cf67b56913"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0aca7f90-a560-460a-9f18-8ba07af4701d"}}}}, {"uuid": "73e7c137-a605-4cb7-bbf3-26cdeed2315f", "name": "87f74108-c47a-4732-8a5e-ba596786e074_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6027984746974515, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12293402966163972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ba9cf4ad-f3fd-4227-a19b-2aaad62123f8", "name": "22278bf8-f8dd-4f1c-ab87-9b73b7dbe1d7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "73e7c137-a605-4cb7-bbf3-26cdeed2315f"}}}]}, {"uuid": "4f33ad95-2a70-4770-a098-910ca9f52b56", "name": "load_p1rlv10574_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b4caeee-6304-4a25-a7d8-44c6014b5e37"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ba9cf4ad-f3fd-4227-a19b-2aaad62123f8"}}}}, {"uuid": "875f2236-e580-4421-bef0-f41c0eed5036", "name": "d4a9c871-3f9d-48a9-a724-ec5889420a13_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6027984746974515, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12293402966163972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "98ae50de-25e8-45e5-9aaf-3f1a06befbc1", "name": "dd6ab7a6-3919-4a87-995c-03d757d7f8e2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "875f2236-e580-4421-bef0-f41c0eed5036"}}}]}, {"uuid": "f9a00871-20ba-4f21-bebb-33613bf841e2", "name": "load_p1rlv10574_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b4caeee-6304-4a25-a7d8-44c6014b5e37"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "98ae50de-25e8-45e5-9aaf-3f1a06befbc1"}}}}, {"uuid": "091bf3dc-4ce0-4c92-b4f3-148a0f482cdf", "name": "dc3fc21e-dadf-45ba-8bec-19f14fc3a3c7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.535252812300099, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.708042162201308, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "424df63a-d4c4-49df-9896-f4bf2b07c473", "name": "228ebb4b-92bf-41c6-9d2b-4a7c1797794f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "091bf3dc-4ce0-4c92-b4f3-148a0f482cdf"}}}]}, {"uuid": "cfbdf53b-5867-474e-b60c-f40634e804eb", "name": "load_p1rlv10576_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25141e20-0a65-4905-b37f-954ed1a8751c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "424df63a-d4c4-49df-9896-f4bf2b07c473"}}}}, {"uuid": "7019b336-5d5d-484f-b921-9e5aca1d3c6d", "name": "59fe0be2-26b2-41b7-bdc7-7ba3350faf0f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.535252812300099, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.708042162201308, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8cee5bc4-c540-4440-ad24-55b653fd412a", "name": "b4b37538-0702-4489-94ad-1451bdbccbff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7019b336-5d5d-484f-b921-9e5aca1d3c6d"}}}]}, {"uuid": "f9ccbd09-813c-4072-bc2f-1aa56b889574", "name": "load_p1rlv10576_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25141e20-0a65-4905-b37f-954ed1a8751c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8cee5bc4-c540-4440-ad24-55b653fd412a"}}}}, {"uuid": "ce073e85-7f43-43d1-88c2-155ddf7a246d", "name": "00f06c4c-ddc4-4abf-afb5-bdceb596c710_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.261177426225613, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7908181369947367, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a8f9af20-7f19-4bf7-be41-a37c69963df6", "name": "702b8ae1-6285-494d-b679-55db28da0e5f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ce073e85-7f43-43d1-88c2-155ddf7a246d"}}}]}, {"uuid": "32de3124-470c-493e-8a0b-1157ef1af7ae", "name": "load_p1rlv10582_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdfa726f-5606-4ae2-b358-ad664dd7b0e3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a8f9af20-7f19-4bf7-be41-a37c69963df6"}}}}, {"uuid": "f9edb153-baa9-45c1-a696-5e44278f86b3", "name": "ad721249-ca51-45d8-962e-0a9e773e5d9d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.261177426225613, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7908181369947367, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "baaa64b4-3737-4051-9f0b-9d3727462fde", "name": "44ff648c-5a1e-45c3-89bb-8ace748e5de5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f9edb153-baa9-45c1-a696-5e44278f86b3"}}}]}, {"uuid": "442c6a76-1f2b-444a-9201-70b55cf27e61", "name": "load_p1rlv10582_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdfa726f-5606-4ae2-b358-ad664dd7b0e3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "baaa64b4-3737-4051-9f0b-9d3727462fde"}}}}, {"uuid": "33441858-6598-49d0-8453-71c6d90501c5", "name": "1e4ff4e9-c297-4aa5-84e2-f849bcffb5d2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "506125d1-1fed-441c-a96c-ff7cc5ab005f", "name": "8a782648-1632-4447-8a78-89d4d790e3c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "33441858-6598-49d0-8453-71c6d90501c5"}}}]}, {"uuid": "b419a8f6-93e5-4c8f-96c2-6e7960421ba5", "name": "load_p1rlv10583_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0431d17-75da-48c1-965c-875f61b0e9bf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "506125d1-1fed-441c-a96c-ff7cc5ab005f"}}}}, {"uuid": "46ae0867-dcb5-467b-8c07-d3a5302c3791", "name": "010b32c2-c545-4787-be8e-2f7c02fb95ad_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b8dd710d-416d-4930-9f88-b0fefa62cea2", "name": "e09b0ffd-aa74-4154-815a-e46564fce253", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "46ae0867-dcb5-467b-8c07-d3a5302c3791"}}}]}, {"uuid": "9e6b3a5b-3f3a-4880-ba5f-dae0d358a4e7", "name": "load_p1rlv10583_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0431d17-75da-48c1-965c-875f61b0e9bf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b8dd710d-416d-4930-9f88-b0fefa62cea2"}}}}, {"uuid": "a71bb0d6-7cd5-4cb0-aa39-4b03fcbf501f", "name": "6e85531c-5724-434e-bf41-258885a0b74e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.283752349161772, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1583018658461228, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a14c57e3-8928-429f-b8b6-434759fd2792", "name": "05c4c798-47ad-4584-b26d-777b063fcd5b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a71bb0d6-7cd5-4cb0-aa39-4b03fcbf501f"}}}]}, {"uuid": "affed099-9528-466f-9ba6-f50f7bd56991", "name": "load_p1rlv10586_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfbe5665-c020-455a-addc-d3f9514735ed"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a14c57e3-8928-429f-b8b6-434759fd2792"}}}}, {"uuid": "706a7727-9c14-44bb-9f42-f5769b154fbf", "name": "0f2287e2-6648-4316-a7e5-c85a81a46ccb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.283752349161772, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1583018658461228, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "65400728-b7be-4d80-bb6e-68e381270709", "name": "50ffc628-e234-4147-8964-d3c900648e60", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "706a7727-9c14-44bb-9f42-f5769b154fbf"}}}]}, {"uuid": "aca6ee26-2121-4078-a1fb-7eefb2af7234", "name": "load_p1rlv10586_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfbe5665-c020-455a-addc-d3f9514735ed"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "65400728-b7be-4d80-bb6e-68e381270709"}}}}, {"uuid": "998df9b0-50aa-4706-962c-b6a9c63af559", "name": "d8a9d3c7-8558-4027-ab66-7f6ca44c0b08_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.580529910152944, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3492768846801997, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f740fd31-5393-4c25-9cbd-5143edc3f377", "name": "865924bd-36b9-4409-8ca2-1d232656ec43", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "998df9b0-50aa-4706-962c-b6a9c63af559"}}}]}, {"uuid": "98a2757d-3c5d-47f5-a5ef-a267cb357eac", "name": "load_p1rlv10589_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53019a8a-b453-4add-9d2d-e4ab380fce67"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f740fd31-5393-4c25-9cbd-5143edc3f377"}}}}, {"uuid": "c736f350-7e92-4bcd-a808-503bf3dded9c", "name": "8e8b7b9b-4a12-48fd-a14c-20c44555255a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.580529910152944, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3492768846801997, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "179147ef-6495-4bc7-9ace-5174b9ffd0fb", "name": "c488a22b-700a-4256-a5a1-a4d9e1d21a6e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c736f350-7e92-4bcd-a808-503bf3dded9c"}}}]}, {"uuid": "b467a724-c9b6-4c0a-90eb-b75a3fd0f403", "name": "load_p1rlv10589_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53019a8a-b453-4add-9d2d-e4ab380fce67"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "179147ef-6495-4bc7-9ace-5174b9ffd0fb"}}}}, {"uuid": "e0c1e9bf-a608-43ec-b3ab-ff05515704f1", "name": "30465b35-19b7-4740-949a-2d5f1389c11f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.781684048838155, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7643971440160673, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0924a091-904d-42f7-b649-d8c4e062b684", "name": "ec220ee0-75c1-431e-9f5d-98b007931647", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e0c1e9bf-a608-43ec-b3ab-ff05515704f1"}}}]}, {"uuid": "43b43c8c-05dc-4444-9fed-3c3eea1e50be", "name": "load_p1rlv10596_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aad9ea92-9403-4ac0-9aaf-7e845b8c7bb5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0924a091-904d-42f7-b649-d8c4e062b684"}}}}, {"uuid": "212866d9-892a-44ab-9d78-1fa02458a3cc", "name": "f82a8ffb-3899-42d7-8198-177451892f51_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.781684048838155, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7643971440160673, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "516ee468-42ac-4367-941a-45593dd976de", "name": "b737aa9d-6fdd-472a-913f-78c8fe79ed87", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "212866d9-892a-44ab-9d78-1fa02458a3cc"}}}]}, {"uuid": "7b7838ce-89c4-413f-9761-111972a4b000", "name": "load_p1rlv10596_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aad9ea92-9403-4ac0-9aaf-7e845b8c7bb5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "516ee468-42ac-4367-941a-45593dd976de"}}}}, {"uuid": "4d25b7f3-e1e0-432c-bbd2-20c4982bffda", "name": "b7d458c4-81f5-4535-9a34-c06bdafbc719_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.133667846972055, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2625504562375869, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "291e100a-66a8-41c0-bb8e-9d18f760f9dc", "name": "2aa56bbc-393b-4963-891e-67d320f18d6c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4d25b7f3-e1e0-432c-bbd2-20c4982bffda"}}}]}, {"uuid": "7fd0a1eb-8e77-42a0-8a43-1990b29e2e1a", "name": "load_p1rlv10600_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "feb19590-c5f4-4982-9e99-20599f08cfe7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "291e100a-66a8-41c0-bb8e-9d18f760f9dc"}}}}, {"uuid": "93c34184-8439-410b-ab1a-54995d21afe4", "name": "1d458fa6-b09d-4bc8-ade0-0eaf6f62856b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.133667846972055, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2625504562375869, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8afd019e-2169-40ea-b70e-02b9578356bb", "name": "207faf6b-8f69-40e4-97fe-33d345d76c58", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "93c34184-8439-410b-ab1a-54995d21afe4"}}}]}, {"uuid": "e6bf0bb1-8209-47b9-9304-84e1a3ec0e95", "name": "load_p1rlv10600_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "feb19590-c5f4-4982-9e99-20599f08cfe7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8afd019e-2169-40ea-b70e-02b9578356bb"}}}}, {"uuid": "b5dece36-50a7-4842-bbf9-9cdcf07baef7", "name": "8767fde3-ad7a-414e-bc9e-ca67510d2a2c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.35395787140957025, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.14845654114897794, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "71bb45c2-d377-4a99-a4d5-f04aab1c26a7", "name": "1a4c4159-647d-4a55-940a-3d3bc5b56df3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5dece36-50a7-4842-bbf9-9cdcf07baef7"}}}]}, {"uuid": "962db928-09f8-4d43-9e77-fd32dd920c61", "name": "load_p1rlv10610_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b91354e-ce50-44d0-a959-fa451bb9cf20"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "71bb45c2-d377-4a99-a4d5-f04aab1c26a7"}}}}, {"uuid": "3b307419-3523-499b-8ab5-3e84ec6d323b", "name": "bb104de1-36db-46bf-81e0-7ebfe6c1d871_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.35395787140957025, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.14845654114897794, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c328b7ae-4b82-457d-8a1a-9810e282362a", "name": "376a780a-f7e2-4b6a-9e1c-adbbc7cad426", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3b307419-3523-499b-8ab5-3e84ec6d323b"}}}]}, {"uuid": "295f6e77-8da3-43b6-8193-d01761e2adff", "name": "load_p1rlv10610_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b91354e-ce50-44d0-a959-fa451bb9cf20"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c328b7ae-4b82-457d-8a1a-9810e282362a"}}}}, {"uuid": "5a920664-46e5-44a4-abf9-38560768e114", "name": "fc0d786d-53e1-449d-9803-734d144740c8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9149869461814677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5767582022429075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "47fe32f7-b3b9-4ee4-902c-48cc953c93f6", "name": "e6cb8855-dec5-415f-911d-297d7831ccb9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5a920664-46e5-44a4-abf9-38560768e114"}}}]}, {"uuid": "3da235eb-7577-4aab-8863-c8474cb6de00", "name": "load_p1rlv10615_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b175fcb-d1ee-44eb-8f89-826e40c5db1d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "47fe32f7-b3b9-4ee4-902c-48cc953c93f6"}}}}, {"uuid": "4d15b95c-82d8-4b91-aeb5-50fbe216e6de", "name": "f61c42da-6a48-4219-ab9b-8fc1f38764dd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9149869461814677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5767582022429075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8c4eedf7-f50b-42fd-8871-6790d0feb8a4", "name": "c9fda510-ad07-4e41-a244-893e99990fa6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4d15b95c-82d8-4b91-aeb5-50fbe216e6de"}}}]}, {"uuid": "6601651a-f399-4530-9b0b-c9fd05796b8e", "name": "load_p1rlv10615_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b175fcb-d1ee-44eb-8f89-826e40c5db1d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8c4eedf7-f50b-42fd-8871-6790d0feb8a4"}}}}, {"uuid": "2b7045b6-1362-42cf-bb6c-31cf6d4cae79", "name": "ed9bb46e-4447-4388-b0d3-1b09ad2dc42d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7464189326227366, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4011494318939581, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bec56e7a-528d-4b92-b5d0-486b1cbee7fc", "name": "a26888a3-858e-406b-ac7a-2ab68649b0c6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2b7045b6-1362-42cf-bb6c-31cf6d4cae79"}}}]}, {"uuid": "236e5d7e-1f9a-461d-844a-39414ced353d", "name": "load_p1rlv10616_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a5717e0-080e-46ae-918a-64fe4fcba5d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bec56e7a-528d-4b92-b5d0-486b1cbee7fc"}}}}, {"uuid": "4e4ad82d-6794-4073-ac45-9bf871ccf4c6", "name": "ce82cb31-9d2e-498a-a992-9599980183e2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7464189326227366, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4011494318939581, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a2a28822-0c17-4424-bb12-be4aa4b6af2a", "name": "24e55c3b-f642-4d33-84ba-33e0d4172e30", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4e4ad82d-6794-4073-ac45-9bf871ccf4c6"}}}]}, {"uuid": "43c97500-210e-4c50-abff-6d9608e600f9", "name": "load_p1rlv10616_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a5717e0-080e-46ae-918a-64fe4fcba5d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a2a28822-0c17-4424-bb12-be4aa4b6af2a"}}}}, {"uuid": "463f6149-b5d4-438f-a16d-4586f0bc0a43", "name": "422be16a-bf20-40ce-ad49-3394e9c866a2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.316539553342243, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9980015331306656, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d6cd3808-bd69-4b1c-a105-5654fa60cf31", "name": "91573b38-6c73-490f-82a5-e86402cf9f87", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "463f6149-b5d4-438f-a16d-4586f0bc0a43"}}}]}, {"uuid": "29eea145-22f9-4150-94ad-3764b540ef65", "name": "load_p1rlv10621_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "374d5417-b2c4-4d16-9b91-d2f519921fd8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d6cd3808-bd69-4b1c-a105-5654fa60cf31"}}}}, {"uuid": "1644862a-e0b2-4ebb-830d-5aa02ef2083c", "name": "029f2c31-f226-4c23-bfc7-08d84532d0e7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.316539553342243, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9980015331306656, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0d6655f1-c352-4e7b-980a-9045ce071e1e", "name": "a1e08948-18d1-4591-9457-112ac5261a7e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1644862a-e0b2-4ebb-830d-5aa02ef2083c"}}}]}, {"uuid": "2ed5b3ea-f3ae-475e-8aa6-c5bfe5aa1b73", "name": "load_p1rlv10621_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "374d5417-b2c4-4d16-9b91-d2f519921fd8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0d6655f1-c352-4e7b-980a-9045ce071e1e"}}}}, {"uuid": "c31478e6-d929-4e98-b045-c71b4087ad9e", "name": "c06ea238-dd56-4f76-a18a-9b96099385f1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.45600682921886, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9975893759791478, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7b0fcda8-4fd9-4888-a3c8-7a064f3a0514", "name": "20858e21-f5be-4bc2-a069-a8068e7695f4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c31478e6-d929-4e98-b045-c71b4087ad9e"}}}]}, {"uuid": "9ee800d6-2926-45c5-b6d4-172a40ee6b6e", "name": "load_p1rlv10627_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32406d7d-51f9-4c16-900b-526985e5f62b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7b0fcda8-4fd9-4888-a3c8-7a064f3a0514"}}}}, {"uuid": "8d18bbd5-8fcc-4978-8b60-29e2529c0513", "name": "6ae0e2e9-df9d-4148-97f8-233de83aa4f4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.45600682921886, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9975893759791478, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4b6b3d03-cac6-4782-b4c3-d9055a264d8b", "name": "db365dd3-dfa0-4c92-9bfc-e5963b6beced", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8d18bbd5-8fcc-4978-8b60-29e2529c0513"}}}]}, {"uuid": "a2c989ea-ede9-4302-b016-020257901a81", "name": "load_p1rlv10627_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32406d7d-51f9-4c16-900b-526985e5f62b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4b6b3d03-cac6-4782-b4c3-d9055a264d8b"}}}}, {"uuid": "653ced00-1a70-4461-a7f6-a46782d611fb", "name": "b0d67803-8e00-442d-b29d-be88928222a0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.625789834877447, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.7705314525486966, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f000b9e4-f294-460c-9c34-682dee4dd32f", "name": "8089d052-21f9-42c0-a786-82669cbf06ec", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "653ced00-1a70-4461-a7f6-a46782d611fb"}}}]}, {"uuid": "7bbb89a7-837a-40c9-81e6-6140afcbb9bc", "name": "load_p1rlv10629_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e183b3e8-d995-4f1e-baee-8d9d4add157e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f000b9e4-f294-460c-9c34-682dee4dd32f"}}}}, {"uuid": "c75500b4-b35d-407d-8f47-15b6ddee22c7", "name": "6a8d26b5-3a9c-429a-9e31-330ff08e2951_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.625789834877447, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.7705314525486966, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e561abf6-354f-47f3-b5b8-2822f6d8891b", "name": "9627e5cb-4670-4bea-8f37-6b4ac968697f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c75500b4-b35d-407d-8f47-15b6ddee22c7"}}}]}, {"uuid": "d30485b2-f695-4972-b2a0-8205cb6a63c6", "name": "load_p1rlv10629_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e183b3e8-d995-4f1e-baee-8d9d4add157e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e561abf6-354f-47f3-b5b8-2822f6d8891b"}}}}, {"uuid": "0be7dab3-4ef7-4396-908e-c67399cca48a", "name": "bdcfe216-985a-423d-a716-8996ebdea531_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.125662061080136, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6733739749908499, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "28e783ef-c07f-4016-a491-53d49ddc21c8", "name": "26f86049-1b09-4339-ac49-8d0f10195020", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0be7dab3-4ef7-4396-908e-c67399cca48a"}}}]}, {"uuid": "09da0e23-f708-49f8-b813-bda8c90d15ae", "name": "load_p1rlv10630_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d60a935-dc9b-48ea-8ee7-9b682452035e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "28e783ef-c07f-4016-a491-53d49ddc21c8"}}}}, {"uuid": "c647e0fd-2e92-431a-8bb0-efebf3669424", "name": "b698fe6e-a967-423a-be37-144d8a5edea4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.125662061080136, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6733739749908499, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b71ca818-e973-4c59-9900-3bf0adb156fa", "name": "314aeea4-6250-4fa3-a96c-542ebc6e63f0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c647e0fd-2e92-431a-8bb0-efebf3669424"}}}]}, {"uuid": "5785d1c0-ba23-47eb-8707-a652c3394c89", "name": "load_p1rlv10630_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d60a935-dc9b-48ea-8ee7-9b682452035e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b71ca818-e973-4c59-9900-3bf0adb156fa"}}}}, {"uuid": "28b97377-d18d-4b60-9fca-e275e912c1c0", "name": "1eb51cbf-a614-4010-8d85-3031944396ef_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4699462180170992, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3815978523472859, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a04d5ba8-580f-4c23-afea-273c028b13a0", "name": "3ca967da-a3b3-44f3-a92f-2c7122f74989", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "28b97377-d18d-4b60-9fca-e275e912c1c0"}}}]}, {"uuid": "bb0803a9-ffed-4930-85ac-23fc778bea77", "name": "load_p1rlv10634_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3184f056-3b5f-403d-86a0-f9b28d6bb3e3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a04d5ba8-580f-4c23-afea-273c028b13a0"}}}}, {"uuid": "a7f4f6a8-df1c-44b1-9861-e21c9ec35731", "name": "9b69478f-847b-4ba5-9717-b8f663214aff_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4699462180170992, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3815978523472859, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "955bb2fc-75c9-456e-b65a-14916d6ced7b", "name": "2527f77e-53d9-412a-a32a-f3ea5d666ff1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a7f4f6a8-df1c-44b1-9861-e21c9ec35731"}}}]}, {"uuid": "b95dbc99-087a-46b2-bee8-c253dafd753a", "name": "load_p1rlv10634_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3184f056-3b5f-403d-86a0-f9b28d6bb3e3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "955bb2fc-75c9-456e-b65a-14916d6ced7b"}}}}, {"uuid": "a027f1ba-5e36-4e14-8867-e8750b9b3e88", "name": "77d960dd-6e4b-4835-af96-4ff160700260_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.444725768387703, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6902267912659802, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "751a9fe0-cc15-4d54-976f-9c9b44796aa8", "name": "f869e91b-9bbd-41eb-b0d9-b723b1f74a78", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a027f1ba-5e36-4e14-8867-e8750b9b3e88"}}}]}, {"uuid": "074c693a-da67-459d-b817-3848a9649671", "name": "load_p1rlv10637_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9510bd0-2bba-4522-bfbe-20b94ea400b6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "751a9fe0-cc15-4d54-976f-9c9b44796aa8"}}}}, {"uuid": "70233a64-93d7-48a5-a06f-0600b5583265", "name": "97d43e0e-f26c-4fdc-ba4f-dbe0fac30736_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.444725768387703, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6902267912659802, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e046118c-7973-4191-a90f-8d40c5b13230", "name": "da65b232-5e9a-486f-a95b-08db42c934d3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "70233a64-93d7-48a5-a06f-0600b5583265"}}}]}, {"uuid": "78a39f4f-3259-49ea-a016-d0b6b770a82a", "name": "load_p1rlv10637_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9510bd0-2bba-4522-bfbe-20b94ea400b6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e046118c-7973-4191-a90f-8d40c5b13230"}}}}, {"uuid": "fadd79c0-580a-4d5e-9b5e-4da9d0191025", "name": "421e5657-d3b4-4c77-910e-a3470738ed61_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.639205904339139, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.495473092652384, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "296cc9cb-beef-41c6-ae8e-7d039b1b7402", "name": "ca951ebf-49ea-4e9c-926c-27e69045a428", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fadd79c0-580a-4d5e-9b5e-4da9d0191025"}}}]}, {"uuid": "83f977da-d0de-4535-baeb-367c8d9a3bed", "name": "load_p1rlv10641_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73ada6ad-ace7-46c1-80f7-2cb33cf4cdb3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "296cc9cb-beef-41c6-ae8e-7d039b1b7402"}}}}, {"uuid": "6244ef9d-3ee0-4a79-a3cf-e130b5de1618", "name": "082e46e7-c3cd-4225-8e60-096b9eb9a590_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.639205904339139, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.495473092652384, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "521f0d48-d008-471b-b45d-f7bf007a4ceb", "name": "ca87f831-2281-423e-803b-1aac098aaabb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6244ef9d-3ee0-4a79-a3cf-e130b5de1618"}}}]}, {"uuid": "6bb625d2-9233-43f7-8321-cfc6b33e6e72", "name": "load_p1rlv10641_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73ada6ad-ace7-46c1-80f7-2cb33cf4cdb3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "521f0d48-d008-471b-b45d-f7bf007a4ceb"}}}}, {"uuid": "f91053fa-fba9-4b1a-94f3-b5dfda7e789f", "name": "55e3c28f-a550-42dc-b7cc-cb2f5f0dddfd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5996895391512607, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5332968923160806, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "da312d03-f181-4ea8-8476-b4e00dc50cb3", "name": "67cf474e-c021-428e-a983-8816bde7e8f8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f91053fa-fba9-4b1a-94f3-b5dfda7e789f"}}}]}, {"uuid": "e3969318-5b8f-4511-815b-c97286011e74", "name": "load_p1rlv10663_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8198c1c5-67e0-49b9-b11a-1f266f7f4bcb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "da312d03-f181-4ea8-8476-b4e00dc50cb3"}}}}, {"uuid": "6957f6ed-5631-42d6-9d60-cee07aa633d1", "name": "a2574217-f0bc-401c-aa12-2fe1c5ab5bb8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5996895391512607, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5332968923160806, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "85f0f261-6c1b-4794-ac26-c0f8f6be3265", "name": "da6eba67-b155-4618-ae2b-bf28e68e16c8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6957f6ed-5631-42d6-9d60-cee07aa633d1"}}}]}, {"uuid": "90ca281a-a8a7-4109-9b92-b7053ff76551", "name": "load_p1rlv10663_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8198c1c5-67e0-49b9-b11a-1f266f7f4bcb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "85f0f261-6c1b-4794-ac26-c0f8f6be3265"}}}}, {"uuid": "364ef7a1-6b22-425f-aa38-1667cc9652de", "name": "b02ac72c-6bab-4491-a7df-9856c068a576_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9149869461814677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5767582022429075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "12c2a122-0ec2-4129-90ee-9a330e839fb7", "name": "a142bbc2-148a-4fa0-be13-8a785682e3e2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "364ef7a1-6b22-425f-aa38-1667cc9652de"}}}]}, {"uuid": "e5b3e471-5f92-44ad-b659-16e3ab78dcf4", "name": "load_p1rlv10720_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3d48c0e-704d-4205-94a2-ee74be7ae350"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "12c2a122-0ec2-4129-90ee-9a330e839fb7"}}}}, {"uuid": "2ebeaab4-4842-4216-bd44-71dc5c2a7f6f", "name": "c7a07059-5ecf-411b-bee2-5ceb38f53633_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9149869461814677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5767582022429075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "41144dbe-6edf-48e6-931c-82121205ff38", "name": "212c5a0a-514f-4b2c-8912-4cef4b7adb80", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2ebeaab4-4842-4216-bd44-71dc5c2a7f6f"}}}]}, {"uuid": "d4f4e6d2-0731-455b-a58f-11e4d5d1b78e", "name": "load_p1rlv10720_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3d48c0e-704d-4205-94a2-ee74be7ae350"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "41144dbe-6edf-48e6-931c-82121205ff38"}}}}, {"uuid": "7049ada4-9114-4342-95bf-162266ecb2ba", "name": "209d18ad-3da4-4a0a-a18d-139fd7eff92e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.459276697523187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8425022918187992, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b16a6e95-c8f5-4782-94af-ed256de9d106", "name": "bb9c6d31-7bb7-4c8a-b7fc-eb53006db484", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7049ada4-9114-4342-95bf-162266ecb2ba"}}}]}, {"uuid": "a45093a1-aeb2-4aad-9a1c-57eef425994a", "name": "load_p1rlv10955_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75dbf8f0-4cb6-49b7-a2a5-f98e9ff4b8df"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b16a6e95-c8f5-4782-94af-ed256de9d106"}}}}, {"uuid": "da9d1374-3cb5-497a-97ba-27c9750ad746", "name": "0730f85a-c922-453d-bd82-9ee41aa7376d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.459276697523187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8425022918187992, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "08eb6627-ce4a-4673-957c-3df6796e63f0", "name": "b114394d-af7c-435f-ad7a-d1779837681a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "da9d1374-3cb5-497a-97ba-27c9750ad746"}}}]}, {"uuid": "d03d68b7-65eb-4249-be52-dd2a1dbe7650", "name": "load_p1rlv10955_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75dbf8f0-4cb6-49b7-a2a5-f98e9ff4b8df"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "08eb6627-ce4a-4673-957c-3df6796e63f0"}}}}, {"uuid": "f40aa2e5-798f-468f-93f9-958f2ae92bfd", "name": "811e6f6f-9ece-4150-80f3-983552fe8aac_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.42648220197083947, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17627708866943506, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e8a38e5e-7db6-4ecb-b58c-9dcaac9f11eb", "name": "71370420-00b4-4479-aee6-1c11890b72a5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f40aa2e5-798f-468f-93f9-958f2ae92bfd"}}}]}, {"uuid": "e5e82ab0-0cc3-4445-a080-eff62f94cd34", "name": "load_p1rlv11048_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a8fc823-6fe8-4a3b-9437-68aa751f5e3b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e8a38e5e-7db6-4ecb-b58c-9dcaac9f11eb"}}}}, {"uuid": "1013b4ee-68cb-4342-936f-ce6ebcddd288", "name": "b1fd9cc5-31c7-4176-b403-2656e3c2ce7a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.42648220197083947, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17627708866943506, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b678eeac-b15d-4766-8549-1eb6d5dc61bf", "name": "474536a9-ccf9-4eb4-9c23-35857083a349", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1013b4ee-68cb-4342-936f-ce6ebcddd288"}}}]}, {"uuid": "65b91a42-c72a-48d4-a306-71c83189ddca", "name": "load_p1rlv11048_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a8fc823-6fe8-4a3b-9437-68aa751f5e3b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b678eeac-b15d-4766-8549-1eb6d5dc61bf"}}}}, {"uuid": "8bb152c5-aaf8-40a7-8604-4360a5122b95", "name": "e31634b5-7017-47ab-b867-88b81e3a7163_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0788570276665777, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5949433355568994, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cf79dcb8-43f9-49d0-ab1e-f6e5cd137ec8", "name": "ea8a6cc2-20d2-42ad-a5cb-78d22731cb1c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8bb152c5-aaf8-40a7-8604-4360a5122b95"}}}]}, {"uuid": "ee8dcbf3-9e3a-431f-9108-40418a72d162", "name": "load_p1rlv11380_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f949a06a-817e-4666-95bb-9536ce06a694"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cf79dcb8-43f9-49d0-ab1e-f6e5cd137ec8"}}}}, {"uuid": "9fb0c3ac-d337-4dde-bedc-2f4bbba5ddef", "name": "f5c2b463-2dea-4336-8db0-a1001296e30a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0788570276665777, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5949433355568994, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5508212d-10cb-4e84-a89a-a39c0ba9e6e7", "name": "5db1c0a2-9f61-413e-b9fc-253e73f7889b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9fb0c3ac-d337-4dde-bedc-2f4bbba5ddef"}}}]}, {"uuid": "2dcd8ef1-01fd-44a8-af9e-6a40ebde70ab", "name": "load_p1rlv11380_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f949a06a-817e-4666-95bb-9536ce06a694"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5508212d-10cb-4e84-a89a-a39c0ba9e6e7"}}}}, {"uuid": "f11640f5-490c-4a9d-adbe-3a2bddcc1d95", "name": "630809d5-43e2-4522-b987-732d50a76bca_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.122083974307247, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.832996158964583, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "278ca58d-0aec-48ce-8f6d-022a2552ce18", "name": "ae7fadf0-a2dc-452a-a866-31b4daec1911", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f11640f5-490c-4a9d-adbe-3a2bddcc1d95"}}}]}, {"uuid": "34642993-ddc9-4c08-bf35-b04592e73168", "name": "load_p1rlv11384_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0c23aea-471f-4d10-9500-1bc14a67d7e7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "278ca58d-0aec-48ce-8f6d-022a2552ce18"}}}}, {"uuid": "360fefe8-8b88-4807-aa47-17a5de0df06d", "name": "d0ae83c6-a7c4-4e1a-95e5-bebea8ece424_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.122083974307247, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.832996158964583, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3bb00d31-4128-4f55-bdd8-9a989ab63a16", "name": "cd66eb38-760d-4dac-9177-b9385426979f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "360fefe8-8b88-4807-aa47-17a5de0df06d"}}}]}, {"uuid": "1431994c-a7e8-4e06-8ba2-4384f422d5b7", "name": "load_p1rlv11384_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0c23aea-471f-4d10-9500-1bc14a67d7e7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3bb00d31-4128-4f55-bdd8-9a989ab63a16"}}}}, {"uuid": "526a60db-5260-4cfe-a3d6-ce7cbc422a6b", "name": "cbaffa95-fa01-45a7-99ef-34477a88115a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 10.509020108523046, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.6522347064707315, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "79136e75-b2b8-4bd4-9360-0d672af1e684", "name": "55cb41d2-e75a-414e-8893-9f575d733c50", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "526a60db-5260-4cfe-a3d6-ce7cbc422a6b"}}}]}, {"uuid": "0cf0d892-3e55-4a93-a396-6b5d00cba278", "name": "load_p1rlv11385_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2115e8bb-fe49-49ad-8687-68feca212557"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "79136e75-b2b8-4bd4-9360-0d672af1e684"}}}}, {"uuid": "b2722973-8fe5-41d6-856b-01957ca2efb6", "name": "4c8dfd26-9575-44c2-8877-ec3dceddecec_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 10.509020108523046, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.6522347064707315, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c3a4d236-5526-4eaf-b69c-81f9f7b57cb6", "name": "eb107080-b20d-42c3-9e00-87dc33942c0e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b2722973-8fe5-41d6-856b-01957ca2efb6"}}}]}, {"uuid": "899f5896-8be0-4757-b0be-e3235ceff34b", "name": "load_p1rlv11385_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2115e8bb-fe49-49ad-8687-68feca212557"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c3a4d236-5526-4eaf-b69c-81f9f7b57cb6"}}}}, {"uuid": "98be4d9c-2302-41b6-9f5b-4124b7bedc5b", "name": "be52d5eb-3fdd-4f36-bc38-914bdf52b39f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.480517361983766, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0183082338731784, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e52315c8-e7e3-4682-8066-90ef82614883", "name": "0259a1c5-11af-4e90-a192-7575b8ccd45d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "98be4d9c-2302-41b6-9f5b-4124b7bedc5b"}}}]}, {"uuid": "4c2cd8dc-dc30-464f-a4f6-ae32fbbd247e", "name": "load_p1rlv11386_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f512d86-c9d9-4f58-9d5a-418d0732dc94"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e52315c8-e7e3-4682-8066-90ef82614883"}}}}, {"uuid": "9efa0853-fb2f-400c-ad76-17bc96185208", "name": "2d808018-f753-4122-8b76-c102272718fc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.480517361983766, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0183082338731784, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "78a80a75-a6a5-4450-b3a2-26efb704dc06", "name": "6a48081b-2edc-4ef6-96ff-51221e6a3bb5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9efa0853-fb2f-400c-ad76-17bc96185208"}}}]}, {"uuid": "f3b9c812-99d0-42c0-aaba-a48a0440d18c", "name": "load_p1rlv11386_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f512d86-c9d9-4f58-9d5a-418d0732dc94"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "78a80a75-a6a5-4450-b3a2-26efb704dc06"}}}}, {"uuid": "449a0c3d-1ba5-4099-9a54-1e94666184c9", "name": "16305d34-b9f3-4562-b126-f1a81d200b85_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4651344294517608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7736313908316925, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e7421110-4b71-4cca-9a89-108b52acf66b", "name": "16ac7d63-c464-4a44-91d6-7f7731be9d2b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "449a0c3d-1ba5-4099-9a54-1e94666184c9"}}}]}, {"uuid": "18607566-7803-4c38-875a-dcd43eb95cda", "name": "load_p1rlv11387_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbca8c57-0da4-4368-9821-7a9ca4282173"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e7421110-4b71-4cca-9a89-108b52acf66b"}}}}, {"uuid": "28751ce9-4f0f-43d8-a5a6-82b259be16d2", "name": "048de35a-8050-4d9a-99e1-996a10b8d873_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4651344294517608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7736313908316925, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "46cf857e-b861-4c96-9ddd-8f93f3999ff3", "name": "62942fa3-ff93-4763-b6e4-7e47e0ee32a5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "28751ce9-4f0f-43d8-a5a6-82b259be16d2"}}}]}, {"uuid": "242d0f50-b01f-465a-b6ad-42e3957d6adc", "name": "load_p1rlv11387_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbca8c57-0da4-4368-9821-7a9ca4282173"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "46cf857e-b861-4c96-9ddd-8f93f3999ff3"}}}}, {"uuid": "65dcd61c-606d-40c5-ac84-5c883bfd958a", "name": "7e0228c2-e3a9-4eb2-9609-4c43c4c479a4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4359784649582454, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.14838741475370543, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b35b4c6e-6f59-4eff-bcaa-d55880e1a26c", "name": "448c1537-1044-4341-8cc4-17303fdc01f6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "65dcd61c-606d-40c5-ac84-5c883bfd958a"}}}]}, {"uuid": "061ac5e1-4491-4054-a774-49521eab7009", "name": "load_p1rlv11388_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12377bf0-f258-4c29-ab26-e938c95ee25c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b35b4c6e-6f59-4eff-bcaa-d55880e1a26c"}}}}, {"uuid": "4c928ce3-4607-4184-a739-4aec1d7d889a", "name": "2631c714-8f91-4974-becb-b4af853a819c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4359784649582454, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.14838741475370543, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bcbddbf6-2fa2-44d7-8332-a0de0780b2c5", "name": "8b212604-4f4d-4843-a575-054512258d30", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4c928ce3-4607-4184-a739-4aec1d7d889a"}}}]}, {"uuid": "8a4b10c5-a6db-4ed7-8e35-6f998a22b4ae", "name": "load_p1rlv11388_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12377bf0-f258-4c29-ab26-e938c95ee25c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bcbddbf6-2fa2-44d7-8332-a0de0780b2c5"}}}}, {"uuid": "79d552d3-cee0-4a5c-b1a2-75be1d6a51c7", "name": "3bdb2f3f-9a78-4cc3-a63c-8cf570881f21_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5261964028176471, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5335215898246958, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7a49efe3-5daa-47c4-815e-2716df97977c", "name": "5fdfa4f1-eddf-4d3d-b9d7-0e9b2936dc09", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "79d552d3-cee0-4a5c-b1a2-75be1d6a51c7"}}}]}, {"uuid": "4ddb8c43-6e0c-4309-8132-cca83f8e4659", "name": "load_p1rlv11390_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b6420b1-3456-42fc-9266-c2b84e063cec"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7a49efe3-5daa-47c4-815e-2716df97977c"}}}}, {"uuid": "44b3e1b7-6f21-40fb-90f8-ada5d654828f", "name": "b0bbc030-b3ae-48cb-add4-c76f9579a136_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5261964028176471, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5335215898246958, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a1a95b33-a327-433e-a614-fe431f7fa246", "name": "592346aa-cb58-403e-b561-9fd691bdeddb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "44b3e1b7-6f21-40fb-90f8-ada5d654828f"}}}]}, {"uuid": "8b62b715-2222-4d0f-bb32-eb15d0362481", "name": "load_p1rlv11390_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b6420b1-3456-42fc-9266-c2b84e063cec"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a1a95b33-a327-433e-a614-fe431f7fa246"}}}}, {"uuid": "559142c0-923c-48cb-a663-08acf9b99abe", "name": "edd46b4f-039e-4197-bea5-a0a193e9034c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.056520022279634, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8635401886215074, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "755f07e7-916c-4a53-8b8e-fdbe8a86ed7e", "name": "8800987f-4611-48c6-be6e-61646d7a93f9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "559142c0-923c-48cb-a663-08acf9b99abe"}}}]}, {"uuid": "2f3b07f5-6d3b-47c6-b03f-62a581a26356", "name": "load_p1rlv11392_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e740a352-ac8f-4ae2-ace3-254fccd7f96f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "755f07e7-916c-4a53-8b8e-fdbe8a86ed7e"}}}}, {"uuid": "4574b2d1-fc8e-49ff-a25a-fc07d36b301d", "name": "e63794ba-c4ae-44ae-b439-bd3343a501d5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.056520022279634, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8635401886215074, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "756fa955-9680-480f-85b2-d5b52b29f99e", "name": "083c63fe-380e-41f3-9ba3-62772e37b557", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4574b2d1-fc8e-49ff-a25a-fc07d36b301d"}}}]}, {"uuid": "59c6d232-98a9-47e1-bed2-5e872041a8d2", "name": "load_p1rlv11392_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e740a352-ac8f-4ae2-ace3-254fccd7f96f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "756fa955-9680-480f-85b2-d5b52b29f99e"}}}}, {"uuid": "462390c9-21da-4beb-9fc6-0f0467cb6409", "name": "d7557778-2990-4193-bcab-760f907a022b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6676306342135938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5123446143614628, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a15ae177-76ec-43f0-a0c2-a1026e8ec787", "name": "dae2d185-f280-4645-9d77-2ef82f12b93c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "462390c9-21da-4beb-9fc6-0f0467cb6409"}}}]}, {"uuid": "278597eb-7589-4179-9c56-8147c045a63a", "name": "load_p1rlv11394_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "996d3e44-142c-42fa-bf4f-2bd1777122dd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a15ae177-76ec-43f0-a0c2-a1026e8ec787"}}}}, {"uuid": "3b3c4397-6414-48a5-990a-6ad45810e2a0", "name": "78e01f6b-d1e6-4496-bbec-41c47850519e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6676306342135938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5123446143614628, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ddd93c03-41d9-4a3c-81c1-1ba375c6c355", "name": "e342d2f3-4b04-4da0-9630-4b32275eb7c6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3b3c4397-6414-48a5-990a-6ad45810e2a0"}}}]}, {"uuid": "ab65142c-9c13-4a8c-8cc7-b104c63b5259", "name": "load_p1rlv11394_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "996d3e44-142c-42fa-bf4f-2bd1777122dd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ddd93c03-41d9-4a3c-81c1-1ba375c6c355"}}}}, {"uuid": "06de4b0e-2909-42a2-959d-aa5a6a240436", "name": "db623204-32c1-44e5-adc3-3c160b103c96_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0716401691896973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6949594139700135, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cb377bff-e6f7-4447-8797-48e32b35cd1a", "name": "0379a339-a2ec-462f-bf7e-b2e2e2a3cc96", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "06de4b0e-2909-42a2-959d-aa5a6a240436"}}}]}, {"uuid": "1e04e619-d127-4ea3-87ed-5eb9556ac87d", "name": "load_p1rlv11395_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29922f55-f36a-4b9e-8836-5f9dadd641b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cb377bff-e6f7-4447-8797-48e32b35cd1a"}}}}, {"uuid": "58db2d51-9c85-4843-83a6-cf19e369b34f", "name": "1c0b8270-742b-4189-8212-bf9144bc65af_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0716401691896973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6949594139700135, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "35c29600-c66e-4dc1-92ab-5574ce2dfe4e", "name": "cad04e0d-401c-4383-901c-67f3f7902974", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58db2d51-9c85-4843-83a6-cf19e369b34f"}}}]}, {"uuid": "908db140-2d30-4690-96be-fe82a41c7d68", "name": "load_p1rlv11395_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29922f55-f36a-4b9e-8836-5f9dadd641b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "35c29600-c66e-4dc1-92ab-5574ce2dfe4e"}}}}, {"uuid": "d5614689-653e-472f-9267-639e0d79a5f1", "name": "fa235b5c-542f-425f-8e7d-585216fa16af_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.8145950466373417, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09093602970127403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "736b85df-cb4e-4e9b-83cf-08ae8f791c33", "name": "9d31ebe3-0876-4f4a-962e-66d5f02222c8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d5614689-653e-472f-9267-639e0d79a5f1"}}}]}, {"uuid": "eb1321da-6da4-4467-b70d-211ce256bd9d", "name": "load_p1rlv11397_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fd316b0-fd98-4193-9c1b-aaa7d92a4284"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "736b85df-cb4e-4e9b-83cf-08ae8f791c33"}}}}, {"uuid": "c9ca1464-7f8d-4a34-9c17-7bcd4af77466", "name": "32f1b799-0314-4cee-9183-a6e1d85e616a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.8145950466373417, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09093602970127403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7ec03626-15d0-482f-8e2c-732f4fa3238e", "name": "de74e497-95d5-40ed-bb4b-e8d05267a90c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9ca1464-7f8d-4a34-9c17-7bcd4af77466"}}}]}, {"uuid": "716a39f1-ba9a-4a83-b6b0-1e8b432d48ac", "name": "load_p1rlv11397_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fd316b0-fd98-4193-9c1b-aaa7d92a4284"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7ec03626-15d0-482f-8e2c-732f4fa3238e"}}}}, {"uuid": "c88b7522-4bd8-49d0-bc8e-b13cc33d39ac", "name": "ac5c5c8d-2059-4ae0-a96e-2e4ef1fc7da5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 23.859207702115498, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3391872562704328, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d557504b-7f7f-4144-bab4-599b9a9b4147", "name": "b361a8d0-1846-477b-ad03-cdb801178674", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c88b7522-4bd8-49d0-bc8e-b13cc33d39ac"}}}]}, {"uuid": "1227d484-abf8-457b-9a16-2712f4293348", "name": "load_p1rlv11398_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97aa01fe-2e60-4617-8c89-d36f425087fe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d557504b-7f7f-4144-bab4-599b9a9b4147"}}}}, {"uuid": "5095d65a-f8f9-43ad-9509-bd1a682fb4de", "name": "1fdd615c-4a8b-45df-a664-b7afad3317cc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 23.859207702115498, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3391872562704328, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1100417b-7762-42c1-84e3-9df8982977b1", "name": "67c88a92-b4bf-420a-842a-9d6c7bf6ff8b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5095d65a-f8f9-43ad-9509-bd1a682fb4de"}}}]}, {"uuid": "ab6196e1-93f6-4f4a-ba8f-dfceaed4b375", "name": "load_p1rlv11398_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97aa01fe-2e60-4617-8c89-d36f425087fe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1100417b-7762-42c1-84e3-9df8982977b1"}}}}, {"uuid": "c85d0dcd-b204-4eab-b636-4bd71b02ac73", "name": "a34faa76-5042-44d6-a7c0-7fa364a76449_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.936474762797392, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1018059929469786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "93ed52e0-29fd-47f1-bcff-9e635f2710c4", "name": "fe1551b2-4899-4058-ba17-33095af84ca7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c85d0dcd-b204-4eab-b636-4bd71b02ac73"}}}]}, {"uuid": "0dd259e1-6337-42d8-8b1a-f1167ba06871", "name": "load_p1rlv11399_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68a9eead-8197-4e82-a444-2a4544ec9ddb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "93ed52e0-29fd-47f1-bcff-9e635f2710c4"}}}}, {"uuid": "475d83d0-97e4-4073-9eb4-c4054a6a73c6", "name": "58181977-2e65-49af-bac7-75f122b75525_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.936474762797392, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1018059929469786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "412f3c1c-8bd1-4f9a-8b78-ff10d0dc33af", "name": "442532b1-69f9-4bd4-be04-fd2195a09331", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "475d83d0-97e4-4073-9eb4-c4054a6a73c6"}}}]}, {"uuid": "14f5c982-a941-47eb-bbe3-5a71b7002ef0", "name": "load_p1rlv11399_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68a9eead-8197-4e82-a444-2a4544ec9ddb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "412f3c1c-8bd1-4f9a-8b78-ff10d0dc33af"}}}}, {"uuid": "1c93c64e-c366-4e8e-be51-80ed7c2dc1ab", "name": "a8d1b8f8-964b-4152-88cf-546f652122a5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7362273540893955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24527287728713068, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1f94519d-76c3-44f3-a4aa-a413daa3fc09", "name": "e9273d34-b533-405f-ab46-06cf3d1cbebd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1c93c64e-c366-4e8e-be51-80ed7c2dc1ab"}}}]}, {"uuid": "1a8b6d99-326a-4863-aafb-24b633c2de28", "name": "load_p1rlv11401_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a215d7dd-8081-4355-9c38-4fd3d2c859c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1f94519d-76c3-44f3-a4aa-a413daa3fc09"}}}}, {"uuid": "ed3a85b5-cc99-4309-803f-597146e69b7e", "name": "c2716fdb-6260-4b4e-99ee-3110b4c6e13b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7362273540893955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24527287728713068, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e6c2ba32-641e-40be-9196-97d7f0cdc413", "name": "e8b64d33-8988-4766-ac6b-b5cf996fed76", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ed3a85b5-cc99-4309-803f-597146e69b7e"}}}]}, {"uuid": "d2095444-e584-4f9e-96d6-7ee82d3f56cf", "name": "load_p1rlv11401_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a215d7dd-8081-4355-9c38-4fd3d2c859c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e6c2ba32-641e-40be-9196-97d7f0cdc413"}}}}, {"uuid": "19e6f0e2-d912-4218-9fd1-fd4d0924d194", "name": "217e84b9-c92a-4813-bda6-016f6ec450d4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.993849790823018, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8230403105677124, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "81000f39-1c4b-48e4-b9af-0b7e8a375a30", "name": "3e931a47-39f4-49a1-b7c1-d1a5dca4f47a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "19e6f0e2-d912-4218-9fd1-fd4d0924d194"}}}]}, {"uuid": "880c8a8f-8311-4eea-85c3-081629e5d51a", "name": "load_p1rlv11671_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "834a5733-5264-4adf-861a-25e494df3e37"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "81000f39-1c4b-48e4-b9af-0b7e8a375a30"}}}}, {"uuid": "fa41be16-4f77-4d8b-8d3c-5bded2c2b3d2", "name": "3a0c9a3d-d0d9-4cef-b356-9296bc4e6ebb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.993849790823018, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8230403105677124, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5de76861-367c-419e-9ebf-d23598dc70c8", "name": "c79e609b-1aa4-4707-894b-5b353a30e4b3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fa41be16-4f77-4d8b-8d3c-5bded2c2b3d2"}}}]}, {"uuid": "ffffb06b-53dd-40e2-88d0-c56f9b9119a7", "name": "load_p1rlv11671_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "834a5733-5264-4adf-861a-25e494df3e37"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5de76861-367c-419e-9ebf-d23598dc70c8"}}}}, {"uuid": "7b0aea3d-5a84-4c93-8187-72c99666a6e7", "name": "9ef80507-36c4-4ed5-a827-d4bab96aa770_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.207629741893862, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.47552489685620736, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cdaab1e9-9218-4f89-879c-17def2df400d", "name": "b090e00b-d7e5-485d-998b-bb3e5a4156b2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b0aea3d-5a84-4c93-8187-72c99666a6e7"}}}]}, {"uuid": "4280bfa9-be32-40fd-bdb0-2e913cfe06f7", "name": "load_p1rlv11674_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "45f2a901-e4f7-4055-a3e2-b60c61d5033e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cdaab1e9-9218-4f89-879c-17def2df400d"}}}}, {"uuid": "942399c1-c215-463d-ab01-2b5b49c33988", "name": "2ada6355-9751-4aa1-8e94-23629ffcbcea_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.207629741893862, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.47552489685620736, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "88679627-5a13-4b2f-9104-c1ab907ef8d2", "name": "7dc64782-55da-4ebf-9774-248dfaf2aeb3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "942399c1-c215-463d-ab01-2b5b49c33988"}}}]}, {"uuid": "3afad982-a47a-4bfd-b962-d5030608149a", "name": "load_p1rlv11674_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "45f2a901-e4f7-4055-a3e2-b60c61d5033e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "88679627-5a13-4b2f-9104-c1ab907ef8d2"}}}}, {"uuid": "7fdeae6b-bad2-4d38-a3eb-b1b886bb88b2", "name": "58c28d80-812f-4f45-b252-f3b925518e56_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.350180554065672, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.234423023465851, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "78047efa-5aae-4c22-bbfd-1e309fce9b3d", "name": "5014b4f3-eb2f-4d8a-b195-fedddd1a282a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7fdeae6b-bad2-4d38-a3eb-b1b886bb88b2"}}}]}, {"uuid": "e21bce72-76a7-41e5-bfdb-2fd16a75d549", "name": "load_p1rlv11677_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b2f121a-2202-43c0-8684-81913a5d6ea9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "78047efa-5aae-4c22-bbfd-1e309fce9b3d"}}}}, {"uuid": "3fb2b49c-5421-416a-81b8-ed45941c710b", "name": "010a5d40-5063-4cec-b10e-a8c6e97802f0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.350180554065672, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.234423023465851, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cbba316b-4388-493d-bebf-b65b224f77b1", "name": "9dc512e3-833a-4d0a-901e-d9d6f764a902", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3fb2b49c-5421-416a-81b8-ed45941c710b"}}}]}, {"uuid": "82bec9a8-854a-4931-b6be-6add2702d1a6", "name": "load_p1rlv11677_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b2f121a-2202-43c0-8684-81913a5d6ea9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cbba316b-4388-493d-bebf-b65b224f77b1"}}}}, {"uuid": "73a7b9d9-ecd8-46e9-8986-42f2efd7f8c6", "name": "84a7323c-c0fb-4d34-8f47-c23cb918fafe_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.646242553828346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.7481060562472628, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2a45bee3-8c33-4cbe-a582-6377ecc23b9f", "name": "84a7323c-c0fb-4d34-8f47-c23cb918fafe_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.646242553828346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.7481060562472628, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7b0b3590-6acf-417b-9bb2-452f23225443", "name": "84a7323c-c0fb-4d34-8f47-c23cb918fafe_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.646242553828346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.7481060562472628, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f34e4e1c-6c8f-4059-adc9-2b64ec93e326", "name": "f086a3d6-c467-4700-abc5-5d2277d44341", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "73a7b9d9-ecd8-46e9-8986-42f2efd7f8c6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2a45bee3-8c33-4cbe-a582-6377ecc23b9f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b0b3590-6acf-417b-9bb2-452f23225443"}}}]}, {"uuid": "199bfa85-465c-4650-8ef3-90f96b88b204", "name": "load_p1rlv11679", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4747e0f3-2a66-4e5a-8160-ac0aabe34489"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f34e4e1c-6c8f-4059-adc9-2b64ec93e326"}}}}, {"uuid": "0e0463d4-ce3e-4fc6-9932-5ad1716ba8a4", "name": "065c9709-49a5-4a99-969e-d1ab3384fb45_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5348201699646123, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21241824123648728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f04a5ba1-dccd-43ea-9d4c-422a4ef9bc8f", "name": "a950f1cc-c8ce-471b-b119-37def2974705", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0e0463d4-ce3e-4fc6-9932-5ad1716ba8a4"}}}]}, {"uuid": "eeae5cd3-47cb-420f-82eb-e82981fc3166", "name": "load_p1rlv11684_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02aef971-5f4a-4ca8-aa33-cce34517bd44"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f04a5ba1-dccd-43ea-9d4c-422a4ef9bc8f"}}}}, {"uuid": "c113a2d0-7a1a-4ef0-b68c-e48e85a1090f", "name": "54701ebb-2c42-4b9d-9413-2113bdd4b2d5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5348201699646123, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21241824123648728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "146aded8-811d-43e7-93c3-2ff6315ddb15", "name": "4fdd7731-7414-4d6a-b123-66bb72d3735f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c113a2d0-7a1a-4ef0-b68c-e48e85a1090f"}}}]}, {"uuid": "39427790-3cc9-4d35-b072-1b8584b28d52", "name": "load_p1rlv11684_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02aef971-5f4a-4ca8-aa33-cce34517bd44"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "146aded8-811d-43e7-93c3-2ff6315ddb15"}}}}, {"uuid": "0f0f3eff-f75b-412b-b376-fd15c18d9230", "name": "711648f9-ebb7-4f4e-b932-f24da15200e6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7134847388598258, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.27646838411203456, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2074fde9-c64d-43a4-9028-6b9f09dd0c72", "name": "910b07e4-fe64-4347-a582-ae11ab6afa54", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0f0f3eff-f75b-412b-b376-fd15c18d9230"}}}]}, {"uuid": "f74274b2-e40e-49ec-a06e-9124509405b4", "name": "load_p1rlv11686_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cda8e361-98b6-49bd-a3ff-30a036a3dc6f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2074fde9-c64d-43a4-9028-6b9f09dd0c72"}}}}, {"uuid": "5b421636-ffa4-4703-9f40-c5fa17a9ef1a", "name": "0009cc4f-de5f-4ad5-aa48-0ff3c85e7cb0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7134847388598258, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.27646838411203456, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a935d79-007f-4e78-9f82-58519fc58985", "name": "64531b1b-d21e-47e0-90b2-87975e64e9bc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b421636-ffa4-4703-9f40-c5fa17a9ef1a"}}}]}, {"uuid": "0128e4c0-7225-4072-81cb-76e07c494424", "name": "load_p1rlv11686_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cda8e361-98b6-49bd-a3ff-30a036a3dc6f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a935d79-007f-4e78-9f82-58519fc58985"}}}}, {"uuid": "bcaa9aa5-7611-4cab-8e97-f648f007f6ec", "name": "8ac0ffc9-1f1f-4e44-b05b-3c6c4e9f4bcf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.685213211371405, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7584354740780123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b6106aee-0e71-4823-9b54-b821dbe6e9e3", "name": "2518ab62-028f-406d-8805-cd8ff9e7c663", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bcaa9aa5-7611-4cab-8e97-f648f007f6ec"}}}]}, {"uuid": "2f03a659-6950-4b38-824c-fcab53770ada", "name": "load_p1rlv11779_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0ba1408-17da-4678-8b04-90c616c3fb48"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b6106aee-0e71-4823-9b54-b821dbe6e9e3"}}}}, {"uuid": "54d15814-1f86-46d8-ba4e-8005594b9e8c", "name": "673f5872-4f13-461c-8547-73d1563f4ca2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.685213211371405, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7584354740780123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "68e84740-bc6d-46b3-b5a1-de230ba2ba8c", "name": "d8fcf121-24ec-4589-af9b-16f85e167894", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "54d15814-1f86-46d8-ba4e-8005594b9e8c"}}}]}, {"uuid": "36b3f0e7-e125-444a-953f-0f418ce90d34", "name": "load_p1rlv11779_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0ba1408-17da-4678-8b04-90c616c3fb48"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "68e84740-bc6d-46b3-b5a1-de230ba2ba8c"}}}}, {"uuid": "2bc5ddc5-f9cf-4c31-a698-e45162a59f52", "name": "de86f7c4-960b-434d-a501-6e2a48c45b5e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8140781365796688, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5845737413475921, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f8b6903-d695-4864-8bd1-5d6ef43823d3", "name": "9f5d99d3-8bbb-4f4b-82b3-c6fa3a499604", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2bc5ddc5-f9cf-4c31-a698-e45162a59f52"}}}]}, {"uuid": "ae28e7f9-10c4-4478-beb9-3cda7def6e12", "name": "load_p1rlv11780_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e9a574d-9537-417a-a811-e22d84b8ea53"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f8b6903-d695-4864-8bd1-5d6ef43823d3"}}}}, {"uuid": "0bb832a9-296f-4ab9-b79f-c6729e9a95f1", "name": "b62bc94e-46b0-4893-b9d9-63b0d76a65c4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8140781365796688, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5845737413475921, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d6007af3-04d8-4d6b-98a0-75e82c07ad9e", "name": "aa693dc2-7f08-4d51-bd8d-957884a3cb4b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0bb832a9-296f-4ab9-b79f-c6729e9a95f1"}}}]}, {"uuid": "2b081bb3-2ae6-44e9-bff1-82782c105da7", "name": "load_p1rlv11780_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e9a574d-9537-417a-a811-e22d84b8ea53"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d6007af3-04d8-4d6b-98a0-75e82c07ad9e"}}}}, {"uuid": "384cf2bf-2e3f-496f-8c9f-7c60d688c039", "name": "8a16d511-aa5c-4d7e-8a2a-dc06a8786cf8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.511185229285174, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8722130080127372, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6a3dec04-d7d9-4d23-9487-257b4c3812db", "name": "49c94614-c682-4183-a3ee-47532aeabbd9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "384cf2bf-2e3f-496f-8c9f-7c60d688c039"}}}]}, {"uuid": "d9cfe7dd-04e6-4dcf-ab7f-2acbe28a3430", "name": "load_p1rlv11781_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28fd9f7c-0195-4529-a972-aa60eced47d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6a3dec04-d7d9-4d23-9487-257b4c3812db"}}}}, {"uuid": "d02a4dfd-0db0-4c84-a0d0-55acac4da244", "name": "f894fb6a-1944-4860-81b8-0d511b69b152_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.511185229285174, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8722130080127372, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "04f35fd9-0ef5-4f14-a6e3-cefc0476f467", "name": "65a6d6bc-d2e4-4d3c-87c0-3c49631c0586", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d02a4dfd-0db0-4c84-a0d0-55acac4da244"}}}]}, {"uuid": "784301f3-c814-4f30-a094-a5ad526eafc4", "name": "load_p1rlv11781_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28fd9f7c-0195-4529-a972-aa60eced47d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "04f35fd9-0ef5-4f14-a6e3-cefc0476f467"}}}}, {"uuid": "c29d78d2-6f86-4a75-8639-46b5737b9f3a", "name": "da9297a7-e14d-4032-80c3-bd916fb0f82e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9571742049653674, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.37384849940856246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c91df66f-cf2c-4308-9e5e-6ae3c4236103", "name": "598bffc5-e44d-4424-b327-473c6b33c699", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c29d78d2-6f86-4a75-8639-46b5737b9f3a"}}}]}, {"uuid": "d4d57c2d-e4fb-45e4-8ca1-5861e1d03e26", "name": "load_p1rlv11782_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "496fc854-bbf8-463b-b16c-12dd1b444cc6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c91df66f-cf2c-4308-9e5e-6ae3c4236103"}}}}, {"uuid": "59ec2523-a40e-4626-83a9-942fb8b00d3c", "name": "0175315c-636a-4bdf-8ec1-9ece9762cfd7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9571742049653674, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.37384849940856246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "55fe2d83-23b8-4e04-bb5f-c0c39fa59d22", "name": "7ffab4d1-ae5f-47c4-bc80-1b5ef215933d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "59ec2523-a40e-4626-83a9-942fb8b00d3c"}}}]}, {"uuid": "dc1725f4-043c-489e-ad6e-a489b6a3ddde", "name": "load_p1rlv11782_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "496fc854-bbf8-463b-b16c-12dd1b444cc6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "55fe2d83-23b8-4e04-bb5f-c0c39fa59d22"}}}}, {"uuid": "719f3565-2a90-447f-b37f-62c4575685a5", "name": "74b0364c-70f7-4cfa-9a50-696d19276a50_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6943701970081404, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21264462112520055, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "04a97427-3eb0-4dd5-8318-2b1618f2db99", "name": "25c4c1f0-dda3-4377-ab72-f6328c96ad2c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "719f3565-2a90-447f-b37f-62c4575685a5"}}}]}, {"uuid": "c0d0846d-b13d-4842-be91-f5890fae2efa", "name": "load_p1rlv11783_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3890375-c01d-44d2-93f9-8d9d60da8852"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "04a97427-3eb0-4dd5-8318-2b1618f2db99"}}}}, {"uuid": "a833347b-51ca-4335-a3b7-2815a8802252", "name": "715e0283-8919-4ab8-8785-bd42398faa71_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6943701970081404, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21264462112520055, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d4366736-a6a8-4466-bdda-dd0d4f71e800", "name": "c972beca-c3aa-48b8-9bb8-2e95b0231cd1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a833347b-51ca-4335-a3b7-2815a8802252"}}}]}, {"uuid": "7a0211f4-3574-4963-8c61-ef4aa454aab7", "name": "load_p1rlv11783_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3890375-c01d-44d2-93f9-8d9d60da8852"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d4366736-a6a8-4466-bdda-dd0d4f71e800"}}}}, {"uuid": "74aeab76-c309-4409-b010-a63870f4cc44", "name": "2bb9988e-44b9-4e7a-a6e6-1457f5fd33ec_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.991741378519742, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22993168819558238, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "70c39461-4170-4085-8dd6-3521bdb1cee8", "name": "f6e7cbfd-d137-4329-92ee-5b9518fb7227", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "74aeab76-c309-4409-b010-a63870f4cc44"}}}]}, {"uuid": "bbaa94b7-26a0-4490-b73f-3f48efcd8109", "name": "load_p1rlv11784_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b66df0bc-6159-42fa-bf49-b8ad17d0e6aa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "70c39461-4170-4085-8dd6-3521bdb1cee8"}}}}, {"uuid": "14682214-bd52-4703-aeee-3855f6362b25", "name": "b01eff19-3110-434c-8ce9-8d5f9e392f71_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.991741378519742, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22993168819558238, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4c696357-ac6d-45a4-962b-355e9c7383a4", "name": "419de2c8-9215-4618-8fc3-0beef31859c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "14682214-bd52-4703-aeee-3855f6362b25"}}}]}, {"uuid": "f229a1db-0bdf-43d2-865e-4cddd2b3dd8c", "name": "load_p1rlv11784_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b66df0bc-6159-42fa-bf49-b8ad17d0e6aa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4c696357-ac6d-45a4-962b-355e9c7383a4"}}}}, {"uuid": "81aa2444-620f-45cc-98de-960fa593c2a6", "name": "5f30cec8-7b02-4fd1-b591-a2178d76d175_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9304883858291884, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.26579705258029934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5b8b6400-52cf-4605-af6d-5c3539407e22", "name": "892222e6-9006-4e8c-b1aa-6f9b3a88f2ca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "81aa2444-620f-45cc-98de-960fa593c2a6"}}}]}, {"uuid": "67f8b117-f8aa-4709-9095-1e625b55aaea", "name": "load_p1rlv11785_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ed0eb774-fcc3-417f-a8a4-fbdb825cc106"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5b8b6400-52cf-4605-af6d-5c3539407e22"}}}}, {"uuid": "1a8a6352-2858-476d-b4ae-541f4571c5d7", "name": "7cc3f58f-d2dc-4bee-9e76-d93a317bd5c2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9304883858291884, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.26579705258029934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "96c26c44-bee9-4f3d-8e1d-05ca261685b3", "name": "3fa9c194-4aa5-456e-a3bb-6475f8f83efb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1a8a6352-2858-476d-b4ae-541f4571c5d7"}}}]}, {"uuid": "7097c4ee-e786-4b71-b2a3-dd97cf49206a", "name": "load_p1rlv11785_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ed0eb774-fcc3-417f-a8a4-fbdb825cc106"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "96c26c44-bee9-4f3d-8e1d-05ca261685b3"}}}}, {"uuid": "b645010e-a80c-4a8e-847c-83155db97703", "name": "48b0ad64-80f4-4225-8b12-69d1c1fce2b4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9049571169929809, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.186253723079565, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "634e1d2e-df5c-4213-ab8a-387c3beb319a", "name": "43db1fb5-a161-48cd-b379-8efe6752dab5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b645010e-a80c-4a8e-847c-83155db97703"}}}]}, {"uuid": "70aaccc7-152f-4181-a716-cb618ede64a9", "name": "load_p1rlv11786_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b15fc66-89d9-483b-9c9f-9b0f39a63b29"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "634e1d2e-df5c-4213-ab8a-387c3beb319a"}}}}, {"uuid": "a27cf930-a2b9-45cb-833a-29d62bb98417", "name": "843c52bb-2b47-41ee-b817-12e7df53e0e9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9049571169929809, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.186253723079565, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4d47c6dc-872d-406b-a442-3bc658bf26b7", "name": "d430dd13-01cb-4cda-9824-6fb09a44693f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a27cf930-a2b9-45cb-833a-29d62bb98417"}}}]}, {"uuid": "257419d1-b753-4d96-bdce-38e1a1cd8134", "name": "load_p1rlv11786_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b15fc66-89d9-483b-9c9f-9b0f39a63b29"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4d47c6dc-872d-406b-a442-3bc658bf26b7"}}}}, {"uuid": "b05a753d-3db7-48b3-b47a-249c98ff3be1", "name": "a4b00cd0-fd5a-4f22-9a52-ed3053b4ee85_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.074192704000552, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.129078804753558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c988968-65a0-4532-a19d-556a07293824", "name": "44cf0c3d-0316-4a19-8733-0a867704b781", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b05a753d-3db7-48b3-b47a-249c98ff3be1"}}}]}, {"uuid": "e253f6fb-990c-4d8b-8948-9a3229cac708", "name": "load_p1rlv12028_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1dfd848-b639-41b5-ad95-2c03a51bd36b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c988968-65a0-4532-a19d-556a07293824"}}}}, {"uuid": "203f3b4c-a1b7-4d7d-8dde-44bba643968d", "name": "a49857dd-c662-47fa-b3d3-1bc2676ae6c5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.074192704000552, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.129078804753558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "07a841f3-9e9e-435e-8921-90257903027f", "name": "5e806831-a196-41a9-9872-c316842d0c89", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "203f3b4c-a1b7-4d7d-8dde-44bba643968d"}}}]}, {"uuid": "f55cbd96-3d00-4c50-9b1e-7949b1ccf7fa", "name": "load_p1rlv12028_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1dfd848-b639-41b5-ad95-2c03a51bd36b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "07a841f3-9e9e-435e-8921-90257903027f"}}}}, {"uuid": "552e95b7-8899-4680-b787-bd09d88fcbad", "name": "d624f5a9-8df5-49d9-8aab-f0ab2829963b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9920550244580673, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.016709072862991, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4a17a3d5-f916-40a8-9a3c-a75fabf7c4b9", "name": "04652eab-da1b-44bb-b119-da71f87b7c49", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "552e95b7-8899-4680-b787-bd09d88fcbad"}}}]}, {"uuid": "15f6d0d3-47f6-405d-860f-4c1f270e1b38", "name": "load_p1rlv12157_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc4d79bb-8ba3-4146-9d50-16db48ffec22"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4a17a3d5-f916-40a8-9a3c-a75fabf7c4b9"}}}}, {"uuid": "616909e4-20b5-4c69-8ff7-6e76d1373619", "name": "9a778301-544c-4279-8090-78f38718cff6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9920550244580673, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.016709072862991, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a0eda67-fcf7-4f79-9913-20f1f19267d3", "name": "3797bb29-31a1-4c97-b879-c67117445909", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "616909e4-20b5-4c69-8ff7-6e76d1373619"}}}]}, {"uuid": "7cf4078b-8cea-45d9-b31f-65e4f30ac480", "name": "load_p1rlv12157_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc4d79bb-8ba3-4146-9d50-16db48ffec22"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0a0eda67-fcf7-4f79-9913-20f1f19267d3"}}}}, {"uuid": "93349afb-bb23-4e5a-96c4-865535c7fce2", "name": "387701da-b42d-4acc-9a36-d349f1506115_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4651344294517608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7736313908316925, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bbe48d7c-1401-44fa-9c7f-809f2a444159", "name": "a44c1150-9305-4d3e-b8c4-f08012ed1336", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "93349afb-bb23-4e5a-96c4-865535c7fce2"}}}]}, {"uuid": "90927d12-f7db-4258-9750-300ae537663f", "name": "load_p1rlv12214_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df9d9de2-6929-48a4-a390-c0e2f129b374"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bbe48d7c-1401-44fa-9c7f-809f2a444159"}}}}, {"uuid": "940f19a6-726f-4ae7-ab9c-62ed4a687ede", "name": "c22de480-94ab-4386-8777-6352bb23c4a9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4651344294517608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7736313908316925, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a359518f-9c6f-44f3-bba7-02c74e67773b", "name": "7cafa9c5-8e2b-4908-8492-7901adf43b91", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "940f19a6-726f-4ae7-ab9c-62ed4a687ede"}}}]}, {"uuid": "be825c77-6ca2-4d5d-99a4-53a5543c2ea2", "name": "load_p1rlv12214_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df9d9de2-6929-48a4-a390-c0e2f129b374"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a359518f-9c6f-44f3-bba7-02c74e67773b"}}}}, {"uuid": "8000ba09-9e9b-47e7-9248-e5cd7eb89b1f", "name": "9390d150-0a92-45a1-a68b-a305c8617dcd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.84153235443771, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.447226409705929, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7c1a452d-e2b6-417d-a4f3-f8b3e9b59441", "name": "413ffaf3-a662-40e4-a1cb-4187df3cca66", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8000ba09-9e9b-47e7-9248-e5cd7eb89b1f"}}}]}, {"uuid": "a5fee8da-8631-4a13-a56e-4b3ac2d97499", "name": "load_p1rlv12217_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4d26673-c304-41de-8b5b-149552601ba4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7c1a452d-e2b6-417d-a4f3-f8b3e9b59441"}}}}, {"uuid": "c90df63f-8a49-4713-98f6-06f17ab46792", "name": "ea12689a-7116-40d9-a027-ca1635ed75dc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.84153235443771, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.447226409705929, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0e05b6fc-4c45-4fd7-9c22-8340c45a3606", "name": "8b56535d-9f54-4ad3-9c6a-791882e318e3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c90df63f-8a49-4713-98f6-06f17ab46792"}}}]}, {"uuid": "e485265f-9f8d-4245-ad17-5d4e5e1c3807", "name": "load_p1rlv12217_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4d26673-c304-41de-8b5b-149552601ba4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0e05b6fc-4c45-4fd7-9c22-8340c45a3606"}}}}, {"uuid": "eb75ab7d-98c0-4140-aef1-328cd7e4116d", "name": "0760525e-b253-41d0-b2cd-687cd73d9c1e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.799969889792979, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7055837837850989, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "042dfb11-6154-4b13-9408-0cd2ab142536", "name": "ab587f0c-6725-497c-ad32-aa49117ef7a8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eb75ab7d-98c0-4140-aef1-328cd7e4116d"}}}]}, {"uuid": "bc041c92-4b53-4a56-a2fb-e457b789cd43", "name": "load_p1rlv12222_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cee79fe8-f140-4be9-aa6b-d56e37fb6857"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "042dfb11-6154-4b13-9408-0cd2ab142536"}}}}, {"uuid": "b0d438e5-c608-402c-b4f6-9f25bd01a42e", "name": "c6b2d280-584e-43d4-a753-6be9b18ab723_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.799969889792979, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7055837837850989, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e7a368d6-2f67-4798-acb9-d269a780643e", "name": "d8f0ae6e-e5fc-404e-94db-798335a77be1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b0d438e5-c608-402c-b4f6-9f25bd01a42e"}}}]}, {"uuid": "79f820d2-8c76-454c-8b6f-c034813dfa94", "name": "load_p1rlv12222_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cee79fe8-f140-4be9-aa6b-d56e37fb6857"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e7a368d6-2f67-4798-acb9-d269a780643e"}}}}, {"uuid": "8a292298-d87c-40ba-99b3-0870bd235430", "name": "4aff0686-b279-4769-8696-0f117f3f32ab_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0087998942532215, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8303357169547151, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7a23e6bd-80a6-48f6-9573-655b5666a234", "name": "4fab9f05-0766-47da-9a87-043511271416", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a292298-d87c-40ba-99b3-0870bd235430"}}}]}, {"uuid": "1711e0a2-ee71-472d-9af5-5fa31beeaac0", "name": "load_p1rlv12225_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8e1f797-9417-447c-8a08-cf00a462ef14"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7a23e6bd-80a6-48f6-9573-655b5666a234"}}}}, {"uuid": "4f1b5334-965c-4525-a322-5fe06c498bb7", "name": "ea7d87bf-96a1-4601-b23b-bda186f96246_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0087998942532215, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8303357169547151, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bdaf1aa2-43b3-47cd-9d94-8e7d2bb7b510", "name": "398b200b-5935-44e0-ab49-e5e703cf9715", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4f1b5334-965c-4525-a322-5fe06c498bb7"}}}]}, {"uuid": "4b1b40e1-5681-448e-a18b-39482f3ba885", "name": "load_p1rlv12225_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8e1f797-9417-447c-8a08-cf00a462ef14"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bdaf1aa2-43b3-47cd-9d94-8e7d2bb7b510"}}}}, {"uuid": "b8deb33a-f898-4d69-97ce-bf091c2f724e", "name": "384f4eb4-eab8-4690-886d-9cf71c4744d7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "55635006-f0f4-4f03-80e7-0beecf5255f6", "name": "6d2bbb29-4ca4-4dd4-8fef-eb4cb60eb63e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b8deb33a-f898-4d69-97ce-bf091c2f724e"}}}]}, {"uuid": "d0db2faa-7719-4473-9f95-ecdc785a82de", "name": "load_p1rlv12538_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b42c2471-9114-4042-980e-dd226ad024a3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "55635006-f0f4-4f03-80e7-0beecf5255f6"}}}}, {"uuid": "38ca2981-1679-4764-a838-f05b5da5b7b2", "name": "e4d803a9-4542-4d57-88bc-b050a947ef29_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b0938b16-1cb9-4e1a-8d43-6ef059d68218", "name": "5ecac895-5d8e-4356-a367-3fc11dfe5b1a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "38ca2981-1679-4764-a838-f05b5da5b7b2"}}}]}, {"uuid": "4bdaf9b4-ca85-4214-b3d0-fab6ecc04fa0", "name": "load_p1rlv12538_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b42c2471-9114-4042-980e-dd226ad024a3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b0938b16-1cb9-4e1a-8d43-6ef059d68218"}}}}, {"uuid": "7af170d2-f91e-49a1-b46a-9d1b3fdac5c2", "name": "fbc4c379-57b8-4715-be21-42a6b2e361f4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.019297318507635, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.02246974709606756, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1fac8763-3ee1-43e7-bcf3-41617c46e963", "name": "f8e332fc-ec82-416e-b3d6-8b14e1a23653", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7af170d2-f91e-49a1-b46a-9d1b3fdac5c2"}}}]}, {"uuid": "28b67365-ae57-4a50-9c3f-0d620c71a219", "name": "load_p1rlv12552_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c42d772-e2a8-45d4-9cf2-2edd7a567b35"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1fac8763-3ee1-43e7-bcf3-41617c46e963"}}}}, {"uuid": "a378f8a4-8021-485f-860d-aa2a2032d46d", "name": "c6a7766f-684b-4d18-8619-a3e8a6fb87ce_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.019297318507635, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.02246974709606756, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f2ffd1ed-8ac4-4d30-bf95-beddb8475dfb", "name": "87f2a343-b853-4cce-827f-1d2dbc76cb67", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a378f8a4-8021-485f-860d-aa2a2032d46d"}}}]}, {"uuid": "9667ccde-7679-492a-80de-2ab510342e72", "name": "load_p1rlv12552_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c42d772-e2a8-45d4-9cf2-2edd7a567b35"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f2ffd1ed-8ac4-4d30-bf95-beddb8475dfb"}}}}, {"uuid": "31838ae9-5bec-4bfe-83d3-5a758bb306f4", "name": "8d2dfc6e-c33b-4d6c-be06-4b5f020bb41a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2219087879829873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3595087789107823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "13e11be6-6fef-46bd-a8ff-df8d3810df63", "name": "7e84ed5f-2b1e-4383-92e9-5ec8f0524021", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "31838ae9-5bec-4bfe-83d3-5a758bb306f4"}}}]}, {"uuid": "5dda57ed-b319-494c-9d87-380540189d12", "name": "load_p1rlv12553_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a29aec49-62a4-41ec-a67c-a84470a23f7b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "13e11be6-6fef-46bd-a8ff-df8d3810df63"}}}}, {"uuid": "10f2e55a-4148-43f9-a8e9-4720e944f9db", "name": "f9bc0bd6-0fa0-4d6b-aa84-287b48754b10_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2219087879829873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3595087789107823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1efcf0f6-12e0-457b-994d-41864b64821c", "name": "f4aef277-ad74-480c-8e1d-45906fd74985", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "10f2e55a-4148-43f9-a8e9-4720e944f9db"}}}]}, {"uuid": "7ce39498-91c4-4f3a-bdee-ca51755f3d8f", "name": "load_p1rlv12553_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a29aec49-62a4-41ec-a67c-a84470a23f7b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1efcf0f6-12e0-457b-994d-41864b64821c"}}}}, {"uuid": "e17e5f3b-1fa7-4e02-83f1-70a065023638", "name": "0500e3cd-6e22-4a48-bd68-2da9bc824009_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "77c2f716-98c7-4441-bb4a-bb0c0f6784c8", "name": "0500e3cd-6e22-4a48-bd68-2da9bc824009_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bf053ec5-8ce2-4779-9c8a-07b6844e1fbc", "name": "0500e3cd-6e22-4a48-bd68-2da9bc824009_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c5a6b4d5-ace0-436b-827a-428dd72a82ca", "name": "a105b17e-37ea-4df0-8c38-0552a55db7ce", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e17e5f3b-1fa7-4e02-83f1-70a065023638"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "77c2f716-98c7-4441-bb4a-bb0c0f6784c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bf053ec5-8ce2-4779-9c8a-07b6844e1fbc"}}}]}, {"uuid": "c6d2bf5b-f470-40ce-b8e4-96cfd0e92a44", "name": "load_p1rlv12555", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc71e486-4a44-466d-bc57-85591b269949"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c5a6b4d5-ace0-436b-827a-428dd72a82ca"}}}}, {"uuid": "1cbd663f-6a1c-4ea8-bded-0d70d902cae6", "name": "f1be257d-cb3a-4fc0-8586-41749bc934a6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.885552109924766, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6041260127278384, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ffec3052-3abb-4450-8007-84eb1a135bdd", "name": "4dc44239-3a7f-4899-a30b-0117e115c1b5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1cbd663f-6a1c-4ea8-bded-0d70d902cae6"}}}]}, {"uuid": "7db8574c-df37-49fc-8c22-8dbf718a039b", "name": "load_p1rlv12557_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fe4d6ae-cca5-476c-981a-a1dcd27b1e84"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ffec3052-3abb-4450-8007-84eb1a135bdd"}}}}, {"uuid": "b0bf587d-8b6c-44a5-a550-676ae3aeb192", "name": "f4b5e26d-8b61-4ee2-8ecf-038f2fb4bca0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.885552109924766, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6041260127278384, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e6120965-3163-44d8-8795-e883b0e34afe", "name": "d3b636f0-790f-4e54-9421-c06065a70246", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b0bf587d-8b6c-44a5-a550-676ae3aeb192"}}}]}, {"uuid": "2ce60fb7-a0a5-4497-b6c9-5145427b22f3", "name": "load_p1rlv12557_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fe4d6ae-cca5-476c-981a-a1dcd27b1e84"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e6120965-3163-44d8-8795-e883b0e34afe"}}}}, {"uuid": "fceb259d-954e-4c0d-a150-78ac533baca1", "name": "e0c5a270-abfa-4883-8baf-ed86fb59ffb0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.408318732620361, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.41814988562464883, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "94430f1e-1b47-4835-9d87-a26d30ac25f4", "name": "5d608f62-d235-48f6-905d-fb4ad378a38e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fceb259d-954e-4c0d-a150-78ac533baca1"}}}]}, {"uuid": "b52d40e1-7dd4-4d66-932d-26e4adbf6420", "name": "load_p1rlv12558_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a427f20-861a-4616-9443-265beaeccca3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "94430f1e-1b47-4835-9d87-a26d30ac25f4"}}}}, {"uuid": "b67cc3a7-efc2-4b73-8760-243e73ec84e9", "name": "a519c9c5-243d-4164-8d71-d9ebf568709c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.408318732620361, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.41814988562464883, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7dad946a-64e6-471e-9d5a-f5c2b56b4453", "name": "28666f42-b2e8-4084-a71f-177b3f358f9a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b67cc3a7-efc2-4b73-8760-243e73ec84e9"}}}]}, {"uuid": "32210c0c-5a99-44d3-89da-dcd3a4957933", "name": "load_p1rlv12558_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a427f20-861a-4616-9443-265beaeccca3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7dad946a-64e6-471e-9d5a-f5c2b56b4453"}}}}, {"uuid": "a7aeb239-b12f-43d8-9254-ceaa8ce5e63e", "name": "7d4a04f8-e89e-4c6a-baff-658b68f7e66d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4ef0e256-0104-4670-ab8e-66c781b92406", "name": "dae4cac6-0ccf-403a-8a0b-4866a8108bc2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a7aeb239-b12f-43d8-9254-ceaa8ce5e63e"}}}]}, {"uuid": "01613cf8-4c62-4ab0-aaf7-05cb942bf041", "name": "load_p1rlv12559_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a47101-b6df-473e-9c7b-96e076c17931"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4ef0e256-0104-4670-ab8e-66c781b92406"}}}}, {"uuid": "512b1fd5-c86c-41ad-a872-0d065db783c7", "name": "65a5f5f0-0ae7-4772-9834-824f5cd68277_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ac9edb43-7944-49af-972a-36bc7f104596", "name": "450e2d61-d419-4788-9fe1-76e179c9155e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "512b1fd5-c86c-41ad-a872-0d065db783c7"}}}]}, {"uuid": "f31a4f65-f744-4d57-848a-782d2ce69a80", "name": "load_p1rlv12559_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a47101-b6df-473e-9c7b-96e076c17931"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ac9edb43-7944-49af-972a-36bc7f104596"}}}}, {"uuid": "8d05d7db-5906-45a2-b1df-57fb6360a6b9", "name": "f2f96b59-653b-4115-b388-497ff52e86b5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4cff9875-7386-458a-9b64-80156936c140", "name": "5af06e9b-23e0-4f6e-a121-7535fd7f88ca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8d05d7db-5906-45a2-b1df-57fb6360a6b9"}}}]}, {"uuid": "c907954e-7703-4c1f-9a10-7dfbbb090930", "name": "load_p1rlv12562_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b0417d3-820d-4daa-aec5-3dcf34e40e00"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4cff9875-7386-458a-9b64-80156936c140"}}}}, {"uuid": "31402909-c881-44f6-9600-4af29e18b80c", "name": "258b099f-96f3-42c9-97ce-6c940296fb86_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d734fea1-2101-4015-8765-d044ecca754e", "name": "718893c7-d6f5-46c0-89e9-ddff0d94b2ef", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "31402909-c881-44f6-9600-4af29e18b80c"}}}]}, {"uuid": "7d67f5e1-9d72-499d-a95a-be3277402376", "name": "load_p1rlv12562_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b0417d3-820d-4daa-aec5-3dcf34e40e00"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d734fea1-2101-4015-8765-d044ecca754e"}}}}, {"uuid": "57030d1d-0515-409b-aa4a-387c467d26ac", "name": "1a257e80-dfde-40c4-aa55-d37da79da837_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "350a7ad6-f872-4619-ae5f-cfd457befd45", "name": "1a257e80-dfde-40c4-aa55-d37da79da837_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "81199978-dcd1-47b2-8456-f39100ae2842", "name": "1a257e80-dfde-40c4-aa55-d37da79da837_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "320af1ec-76c0-4573-9c87-c3be63bcca88", "name": "6dade334-e8c5-4f6d-8279-8cd008e9a44d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "57030d1d-0515-409b-aa4a-387c467d26ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "350a7ad6-f872-4619-ae5f-cfd457befd45"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "81199978-dcd1-47b2-8456-f39100ae2842"}}}]}, {"uuid": "17b19812-d10c-4cc3-8e0b-b93942f5974c", "name": "load_p1rlv12567", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29476f95-f85b-4843-a847-3d9d99da3b74"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "320af1ec-76c0-4573-9c87-c3be63bcca88"}}}}, {"uuid": "f44bfd34-ad29-4174-a161-329b1224269d", "name": "36a08b46-936f-47a7-a34b-83acf6359197_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1813646779377422, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20173832232537287, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b8f01aa2-00fd-4dcd-95d3-ee92c7dc38da", "name": "ce99f5ba-9e66-476d-9b98-d5895b6afb7a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f44bfd34-ad29-4174-a161-329b1224269d"}}}]}, {"uuid": "8c1c77d8-e76c-4eda-bff9-22efc95cca94", "name": "load_p1rlv12936_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "019e419c-9f88-455a-bf48-b89531ed9e51"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b8f01aa2-00fd-4dcd-95d3-ee92c7dc38da"}}}}, {"uuid": "7f3d1ad9-9edb-4501-95e7-11dd23a50986", "name": "f8e1f177-5d01-4890-bfdc-99a3c60f7353_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1813646779377422, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20173832232537287, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "59dc5206-5cf4-4a62-8f4a-564ccced3760", "name": "7e6fccaf-608c-460d-b620-86aa98026b84", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7f3d1ad9-9edb-4501-95e7-11dd23a50986"}}}]}, {"uuid": "64ecfe23-c977-4298-9dc8-22e8d727ecc3", "name": "load_p1rlv12936_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "019e419c-9f88-455a-bf48-b89531ed9e51"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "59dc5206-5cf4-4a62-8f4a-564ccced3760"}}}}, {"uuid": "afa36572-c7ae-4d30-a2cf-34a94041a92f", "name": "95dd7527-7120-47c6-9afa-d40a630910f0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.674261199298095, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1525334183561808, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c66704e3-e385-47ce-b33a-e2c4375ef14e", "name": "7b00e015-39f0-4fc3-86ed-c4037ef252ea", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "afa36572-c7ae-4d30-a2cf-34a94041a92f"}}}]}, {"uuid": "a215654e-7a13-4de0-8afb-2f584ea13270", "name": "load_p1rlv12959_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8418804f-aad5-49df-9916-f427da5089c1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c66704e3-e385-47ce-b33a-e2c4375ef14e"}}}}, {"uuid": "ec3f59ba-2ece-4e43-8236-8c9de91b7627", "name": "5341f2d5-824e-4ce2-a368-edbf3ae10d37_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.674261199298095, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1525334183561808, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5dfda74d-6533-41b2-b54f-7101f1bd6c06", "name": "63791f0a-1239-4534-a7b3-c82111e806d7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ec3f59ba-2ece-4e43-8236-8c9de91b7627"}}}]}, {"uuid": "a9e2e550-8519-457a-9432-96ca8f3494ab", "name": "load_p1rlv12959_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8418804f-aad5-49df-9916-f427da5089c1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5dfda74d-6533-41b2-b54f-7101f1bd6c06"}}}}, {"uuid": "6bafed9c-a79a-43e6-a2a6-6262cbf57402", "name": "6465f966-6ad2-4637-b178-c99221f13579_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.622949952431687, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7401570066486144, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aa680a67-4712-49b6-a6ef-d2abb1acc56c", "name": "c0e0b38a-4d53-4faf-bc78-726feff62d84", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6bafed9c-a79a-43e6-a2a6-6262cbf57402"}}}]}, {"uuid": "a267a065-bc37-434d-b77a-bd9be5993b1e", "name": "load_p1rlv12971_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be845651-8e1c-4b6d-8633-fcbdfb1fd5d4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aa680a67-4712-49b6-a6ef-d2abb1acc56c"}}}}, {"uuid": "d9161e28-a0e8-4632-ae36-7b0369feafe5", "name": "ecbbdcd3-87d4-4093-8c08-7131f570fb59_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.622949952431687, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7401570066486144, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9836cc02-f8d9-4b59-aaeb-a80e647f8b53", "name": "5183ea73-8c25-4849-b8c8-ac8d8262be00", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d9161e28-a0e8-4632-ae36-7b0369feafe5"}}}]}, {"uuid": "aa3223c1-16c1-4b3f-99e7-4134ca4d6bf0", "name": "load_p1rlv12971_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be845651-8e1c-4b6d-8633-fcbdfb1fd5d4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9836cc02-f8d9-4b59-aaeb-a80e647f8b53"}}}}, {"uuid": "bf2243f3-2f82-411a-a167-14dd3432096e", "name": "0e011f34-06de-4749-9462-166fa6b5bab8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.629144238694082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9654448182756213, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0e6b89e2-09ac-43e4-9fdf-5d1f0467c088", "name": "6d835633-768b-4507-aef7-efebcacfcf21", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bf2243f3-2f82-411a-a167-14dd3432096e"}}}]}, {"uuid": "ef085e54-6201-46d3-8f05-3179724d75da", "name": "load_p1rlv13043_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3072c6c-3a40-4e49-bd00-febc8268b135"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0e6b89e2-09ac-43e4-9fdf-5d1f0467c088"}}}}, {"uuid": "048c2b39-a731-4873-a791-7b25cf4be610", "name": "da303c9d-b1f7-4042-8a61-3318d0388810_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.629144238694082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9654448182756213, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "68485ccc-34ca-4e0d-b041-cf3abda83f2c", "name": "9503fa22-df99-4b16-9624-ba5058855d48", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "048c2b39-a731-4873-a791-7b25cf4be610"}}}]}, {"uuid": "cf1311b1-6044-4a3b-b741-8eba3f6a730f", "name": "load_p1rlv13043_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3072c6c-3a40-4e49-bd00-febc8268b135"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "68485ccc-34ca-4e0d-b041-cf3abda83f2c"}}}}, {"uuid": "29ea63e7-0679-4c22-8880-178658313e08", "name": "b0f23629-383c-4a33-8600-91e1c7d72d0b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.67656735172194, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8569955192100605, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a9952cc1-e7a5-411b-bc2b-9b562df4ea90", "name": "2018957d-e361-4656-a49e-7af6f7dd0ec2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "29ea63e7-0679-4c22-8880-178658313e08"}}}]}, {"uuid": "1ecebcd9-1364-4d70-ad28-909bb5b9d8fa", "name": "load_p1rlv13044_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa31c772-8460-4624-a123-64b87ca8d332"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a9952cc1-e7a5-411b-bc2b-9b562df4ea90"}}}}, {"uuid": "72973c4b-1480-4f11-b02c-02b2e34a71c3", "name": "adebbaae-4278-4f65-999f-fd3d7c4d898c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.67656735172194, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8569955192100605, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b55a038b-402f-4d21-8478-cd30f0dffba0", "name": "5b690348-d90e-445d-8fed-7350db417d1e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72973c4b-1480-4f11-b02c-02b2e34a71c3"}}}]}, {"uuid": "abb52718-5636-4abc-9e4b-b1ad17398d48", "name": "load_p1rlv13044_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa31c772-8460-4624-a123-64b87ca8d332"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b55a038b-402f-4d21-8478-cd30f0dffba0"}}}}, {"uuid": "3627100b-bd13-4957-bf7f-5b3dcb399273", "name": "2f7e63ee-606e-4006-8054-fa280fed04a2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.927062407458527, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.5614641711041375, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9696f3af-6d44-4089-8061-b37461d4c4bf", "name": "dcca069b-2167-4bef-9609-3a4a5e037504", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3627100b-bd13-4957-bf7f-5b3dcb399273"}}}]}, {"uuid": "beb721c2-d839-4335-bb0b-504d29a38675", "name": "load_p1rlv13045_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6070414d-09e7-48a7-aec0-c105cc0f1a93"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9696f3af-6d44-4089-8061-b37461d4c4bf"}}}}, {"uuid": "23f1d753-acb9-4529-8473-9d9b923aae89", "name": "838a49c5-8699-4ad8-bef6-e7c55e73e980_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.927062407458527, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.5614641711041375, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9e38c316-0bf1-4c33-b03d-6c2bf7a7b6f4", "name": "8496860e-e0bc-4f29-904a-b4ae24142a88", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "23f1d753-acb9-4529-8473-9d9b923aae89"}}}]}, {"uuid": "39d37fbc-2cb3-45bc-8cf5-cd01fbc253ab", "name": "load_p1rlv13045_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6070414d-09e7-48a7-aec0-c105cc0f1a93"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9e38c316-0bf1-4c33-b03d-6c2bf7a7b6f4"}}}}, {"uuid": "3d8a2220-4e4f-4e81-9717-bb8186a3a84a", "name": "aaf7daa9-44e0-4720-816a-bd6211d51e77_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 15.279136617573831, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5014115237228067, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8fed5cf1-3790-4d6a-abea-a0cdedfcbf66", "name": "86e517e9-c448-4f71-a223-b4a9e03e56ca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3d8a2220-4e4f-4e81-9717-bb8186a3a84a"}}}]}, {"uuid": "d201c1a8-8405-407a-b693-d3e6ecbdfc3b", "name": "load_p1rlv13046_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5edc15fb-49d5-4052-8fad-4979578f6ed1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8fed5cf1-3790-4d6a-abea-a0cdedfcbf66"}}}}, {"uuid": "9693a4ba-33c3-4686-95d8-bd54caac41d7", "name": "192aec90-8be0-407e-8eb1-02d103b8aa8f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 15.279136617573831, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5014115237228067, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6101ba57-b6a3-4b6f-96e4-155b9aaec470", "name": "fa37179a-b466-4601-80e7-601e4e1ea5e6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9693a4ba-33c3-4686-95d8-bd54caac41d7"}}}]}, {"uuid": "c0555aca-c68c-4f8e-9f96-4d02f0aa6ac2", "name": "load_p1rlv13046_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5edc15fb-49d5-4052-8fad-4979578f6ed1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6101ba57-b6a3-4b6f-96e4-155b9aaec470"}}}}, {"uuid": "e4bb654e-d037-44c7-93fb-136954260713", "name": "aedd0946-c9f5-4c4e-9a2d-a162cffd94db_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3374419606114465, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8276898777002473, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "336d306b-9868-4071-b9ad-f2f0b5a68ee8", "name": "bf70eb87-479c-41be-acc2-1f40468a8d77", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e4bb654e-d037-44c7-93fb-136954260713"}}}]}, {"uuid": "a8845610-255f-4497-9140-7e0b22d0ea41", "name": "load_p1rlv13047_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4209bdad-276f-4e07-93e0-78b162ce95cf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "336d306b-9868-4071-b9ad-f2f0b5a68ee8"}}}}, {"uuid": "0e5dc84b-05ee-499d-b21a-da930b8ff0e7", "name": "0f30c492-a1c2-433d-932c-4fadbc3cda54_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3374419606114465, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8276898777002473, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fce9ecb2-402a-4b36-b60f-4380bc572ff2", "name": "97aad36b-aaba-4ba4-8b0f-69233cde3781", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0e5dc84b-05ee-499d-b21a-da930b8ff0e7"}}}]}, {"uuid": "ea5f208e-4405-479a-9249-fdd564e27ac7", "name": "load_p1rlv13047_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4209bdad-276f-4e07-93e0-78b162ce95cf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fce9ecb2-402a-4b36-b60f-4380bc572ff2"}}}}, {"uuid": "a2344f4d-580f-4d1f-8ca7-96074f3a11ca", "name": "ece2f7cf-fbf5-46d5-89e6-03413649b91b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3862445486686554, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0100117110086289, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2ab11757-34f2-4b89-b71a-6fdd1a84a1db", "name": "c0c1eaed-9da8-478f-a901-91ac11e47dd5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a2344f4d-580f-4d1f-8ca7-96074f3a11ca"}}}]}, {"uuid": "da3b6c00-95ce-4543-b2b6-ad5d48e8ed50", "name": "load_p1rlv13048_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "569078be-37c2-4c05-8455-91945eb7fdb9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2ab11757-34f2-4b89-b71a-6fdd1a84a1db"}}}}, {"uuid": "6ccf68b4-da02-4d62-aef9-3c67796369ee", "name": "216328c0-676a-4590-9934-5ddf303cf7d0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3862445486686554, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0100117110086289, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6c2cb862-2147-4b66-9321-30946bf3fddf", "name": "c93767ca-1ca8-472b-9e64-148c1794dace", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6ccf68b4-da02-4d62-aef9-3c67796369ee"}}}]}, {"uuid": "6fccad50-53ea-47b2-b9a4-c004ab2e0953", "name": "load_p1rlv13048_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "569078be-37c2-4c05-8455-91945eb7fdb9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6c2cb862-2147-4b66-9321-30946bf3fddf"}}}}, {"uuid": "88a28a37-de8a-40f3-85a8-ecf02873796a", "name": "8e5e686d-f46a-4930-adcf-16b20d576e59_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.734495706390117, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.8488351310797768, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "02143f59-781d-4f3c-ae65-f5cdf7219e27", "name": "a05253a1-6c79-4fe6-8718-0385e58be912", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "88a28a37-de8a-40f3-85a8-ecf02873796a"}}}]}, {"uuid": "f24deddc-0423-4117-9703-7a99a11e928c", "name": "load_p1rlv13049_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ed85192-4c5a-4c15-ba21-1ba883b03ddd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "02143f59-781d-4f3c-ae65-f5cdf7219e27"}}}}, {"uuid": "a1c08b21-8534-4b31-8cb2-a5d67b33899e", "name": "a63d29ec-7a7d-4e93-841b-a67584b88102_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.734495706390117, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.8488351310797768, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "620b6660-d420-44fc-a878-b0ce12065187", "name": "2326f173-a2c2-4284-84a3-088d473aad62", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a1c08b21-8534-4b31-8cb2-a5d67b33899e"}}}]}, {"uuid": "216972e7-f384-4784-97d7-16866891173d", "name": "load_p1rlv13049_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ed85192-4c5a-4c15-ba21-1ba883b03ddd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "620b6660-d420-44fc-a878-b0ce12065187"}}}}, {"uuid": "5330a24c-1c74-4447-91f5-72636276f9cc", "name": "7c121eb7-6fec-4992-bc39-b0896d5a6423_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 23.2179949774968, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.953694721257675, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6aa3263e-c151-4899-9e82-4a851d6b2b6d", "name": "7c121eb7-6fec-4992-bc39-b0896d5a6423_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 23.2179949774968, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.953694721257675, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c69ddaa1-e2dd-411d-9010-ab6cd872259d", "name": "7c121eb7-6fec-4992-bc39-b0896d5a6423_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 23.2179949774968, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.953694721257675, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "54f818ce-e227-429b-81c2-73c52d992eb5", "name": "0f41eb01-df7d-4d64-b994-d868d16dd02d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5330a24c-1c74-4447-91f5-72636276f9cc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6aa3263e-c151-4899-9e82-4a851d6b2b6d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c69ddaa1-e2dd-411d-9010-ab6cd872259d"}}}]}, {"uuid": "82e9cc65-bb9f-47af-8448-b3675c52f170", "name": "load_p1rlv13050", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "051eba03-4728-4626-8add-5410b5326dc7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "54f818ce-e227-429b-81c2-73c52d992eb5"}}}}, {"uuid": "3c5de08d-4489-4eff-9d3a-df139e6261fa", "name": "b6c5b2c4-f466-45a3-8919-d20bc877b7ca_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.295504020074436, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.753636562958712, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d96577ec-a347-4d9e-b275-74c4e3582e5a", "name": "c16beac3-a33a-4ec1-b3c2-6dd358eb7e26", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3c5de08d-4489-4eff-9d3a-df139e6261fa"}}}]}, {"uuid": "deba2370-2c00-4278-9e40-74318b254dc7", "name": "load_p1rlv13051_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9a855b0-538e-4fab-91f1-93b4ece09409"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d96577ec-a347-4d9e-b275-74c4e3582e5a"}}}}, {"uuid": "2277f042-b321-4549-85c5-bfeefe010c0f", "name": "05b5aa46-f5c1-46a7-a7be-a0916dc3e831_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.295504020074436, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.753636562958712, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "386bd9d3-bf89-4d7f-95d5-9484beb56654", "name": "9ff705f6-657e-4c3b-a184-d722838b010d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2277f042-b321-4549-85c5-bfeefe010c0f"}}}]}, {"uuid": "e9e13a15-8f79-48f8-b00d-112c0955c7ff", "name": "load_p1rlv13051_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9a855b0-538e-4fab-91f1-93b4ece09409"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "386bd9d3-bf89-4d7f-95d5-9484beb56654"}}}}, {"uuid": "e47fc9f6-a620-41d6-8e5e-a4dea78f1d8c", "name": "02707f24-6de0-4f61-9067-fc376ceb4c35_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 19.860755218124574, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.283352762304049, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "90d2a991-1be9-4d3d-b25c-d641f5852ce0", "name": "98b94bea-0497-48c9-83cf-43dc2f58673e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e47fc9f6-a620-41d6-8e5e-a4dea78f1d8c"}}}]}, {"uuid": "c45e9911-1996-4701-87fe-231c8d794fe3", "name": "load_p1rlv13052_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86d59550-d7c8-47e1-a6bc-14b2d50de58c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "90d2a991-1be9-4d3d-b25c-d641f5852ce0"}}}}, {"uuid": "0b19b038-939c-4e2e-8045-86bfef6c145a", "name": "b60560c0-d5ed-443f-ae13-4cc320357fa6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 19.860755218124574, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.283352762304049, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fe9ce19d-3988-4f6f-acf3-8ac26188214c", "name": "21ef59b3-9520-42d9-a4b4-7d46fe81973d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0b19b038-939c-4e2e-8045-86bfef6c145a"}}}]}, {"uuid": "94a58535-40fd-430f-a363-0df23068f8eb", "name": "load_p1rlv13052_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86d59550-d7c8-47e1-a6bc-14b2d50de58c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fe9ce19d-3988-4f6f-acf3-8ac26188214c"}}}}, {"uuid": "8c55e953-e9d0-4f9a-afda-2b8357ad3322", "name": "e5be8e83-343d-4fe3-bd2d-f1ea52abcf56_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.272941497663945, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5660410395064467, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ec02be12-6aad-48e2-a97a-42a76367cb01", "name": "f2b0c48e-02b6-40cf-8f81-327201ddb0b1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8c55e953-e9d0-4f9a-afda-2b8357ad3322"}}}]}, {"uuid": "b030444d-c176-4df9-93ed-356fa73af275", "name": "load_p1rlv13053_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e058437-0138-4305-a33e-d8fa61aed8cc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ec02be12-6aad-48e2-a97a-42a76367cb01"}}}}, {"uuid": "b9a4594e-ecff-4fe1-abef-288a6ec861c7", "name": "a5ccbeed-776c-4cb9-9e01-d994993b293b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.272941497663945, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5660410395064467, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c7e076c8-071b-44a4-82b9-3a65877b8dfa", "name": "4b5acf6d-494a-47de-ad73-bfda2139e333", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b9a4594e-ecff-4fe1-abef-288a6ec861c7"}}}]}, {"uuid": "2593ff8d-6b0c-41be-bf36-255ad70efd32", "name": "load_p1rlv13053_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e058437-0138-4305-a33e-d8fa61aed8cc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c7e076c8-071b-44a4-82b9-3a65877b8dfa"}}}}, {"uuid": "b0c56a5f-1836-4722-a7a7-f077bf3f4645", "name": "d029c9ef-058f-4751-b3cd-a83bf3b24772_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.124330522658403, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7653447086077897, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "98e6961c-f75a-4769-bfdd-47154e878802", "name": "5b818057-a251-4108-ba28-169f909cd66b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b0c56a5f-1836-4722-a7a7-f077bf3f4645"}}}]}, {"uuid": "9839d392-3d5d-4f32-8fb9-d9cdcecf9708", "name": "load_p1rlv13054_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21c6ea4f-ec9d-424e-8743-7175408f9e2c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "98e6961c-f75a-4769-bfdd-47154e878802"}}}}, {"uuid": "13880019-47f5-4b84-9104-ca8a4447df61", "name": "ddc63b09-7b10-4163-87cc-483774534e70_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.124330522658403, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7653447086077897, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "11e31fd7-ec52-4f61-9efb-5a0f0e2a8a45", "name": "cc0e63a9-f9df-434a-bbf6-394f9c1a79ac", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "13880019-47f5-4b84-9104-ca8a4447df61"}}}]}, {"uuid": "4e56214a-a749-4596-8cee-c667bf524484", "name": "load_p1rlv13054_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21c6ea4f-ec9d-424e-8743-7175408f9e2c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "11e31fd7-ec52-4f61-9efb-5a0f0e2a8a45"}}}}, {"uuid": "03c39f62-f346-4ecf-87da-b9ca705e9875", "name": "9928165b-4e5b-4c16-8a43-36d49a23f7a1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.470164086158317, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2411725730358465, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c5708940-7781-463f-bcd1-37b6c01a4cf1", "name": "9746de90-03dd-4bd0-9bcb-c40970aad705", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "03c39f62-f346-4ecf-87da-b9ca705e9875"}}}]}, {"uuid": "dbd96bdb-7497-4e12-a129-f75678931540", "name": "load_p1rlv13055_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387df3d3-5f03-47f4-8b16-bea8815e63d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c5708940-7781-463f-bcd1-37b6c01a4cf1"}}}}, {"uuid": "6f125292-8e7d-415c-87ba-4b4ba7d74463", "name": "b9af170a-b3b6-4e59-9859-9f671b00ecdb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.470164086158317, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2411725730358465, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c10703b2-a476-4671-9c7d-3bc15b542600", "name": "93dd0309-9f55-4a16-adda-c7157a769eac", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6f125292-8e7d-415c-87ba-4b4ba7d74463"}}}]}, {"uuid": "1cf14206-e3aa-4595-b8ce-69a46738d4b2", "name": "load_p1rlv13055_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387df3d3-5f03-47f4-8b16-bea8815e63d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c10703b2-a476-4671-9c7d-3bc15b542600"}}}}, {"uuid": "99c97419-8203-4111-ab56-df4a04e8149f", "name": "b93feca9-d48c-4c0c-b938-910cd5a29adf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.8145950466373417, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09093602970127403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f4184d92-ab07-4d9b-803f-435931250b82", "name": "ef23f723-a264-4e32-9a5d-84f6b35da717", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "99c97419-8203-4111-ab56-df4a04e8149f"}}}]}, {"uuid": "284761d0-ff7d-48c2-8436-493918426886", "name": "load_p1rlv13056_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16584dfd-537d-4b0d-a651-c73d0beabc6d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f4184d92-ab07-4d9b-803f-435931250b82"}}}}, {"uuid": "81b1de48-f250-4a8e-9b53-21944e42f4ed", "name": "70ec6cdc-04cb-4891-bdeb-6b8d57f70743_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.8145950466373417, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09093602970127403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "19359e76-6088-4b0e-8f47-c33f8a19d2f8", "name": "ace47199-3291-4db6-bc3b-65e5536c2fd6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "81b1de48-f250-4a8e-9b53-21944e42f4ed"}}}]}, {"uuid": "367c65ab-12a7-4272-8839-3190caeb0b1e", "name": "load_p1rlv13056_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16584dfd-537d-4b0d-a651-c73d0beabc6d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "19359e76-6088-4b0e-8f47-c33f8a19d2f8"}}}}, {"uuid": "6c5c1197-8967-44f0-85b2-dd43d1bf8829", "name": "fcb5b0f9-8055-434e-a248-0b9d1358fa16_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b535f1cc-a786-4654-808f-1f463aae6dc8", "name": "841c3407-202a-4de9-8727-64ed789e4708", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c5c1197-8967-44f0-85b2-dd43d1bf8829"}}}]}, {"uuid": "31c3c8e3-e973-44e8-8690-5b04d68c366f", "name": "load_p1rlv13057_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c63d163-75bd-4d91-bcfa-229a2e331b1f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b535f1cc-a786-4654-808f-1f463aae6dc8"}}}}, {"uuid": "79a4a57b-5123-4f98-8e18-1d35c301ddd6", "name": "bc86e892-aced-4a06-b06e-d828beeab8ac_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "85960692-2cde-4d5a-b06e-e13af7db5812", "name": "fb457142-7b1a-4c62-a316-43045a4c6b27", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "79a4a57b-5123-4f98-8e18-1d35c301ddd6"}}}]}, {"uuid": "fd8f7923-db76-49bc-a8a3-66b4445c641e", "name": "load_p1rlv13057_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c63d163-75bd-4d91-bcfa-229a2e331b1f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "85960692-2cde-4d5a-b06e-e13af7db5812"}}}}, {"uuid": "72ea28b0-b695-4847-8b76-01579e4b31e6", "name": "cd345cd3-f1ff-41f5-a1a3-c11ab919a3e8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.875608242018149, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1961787734858456, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e9e358ae-8ebc-4bbc-aacf-73d7af4f2b43", "name": "468eefb5-0eb9-4a7c-a496-c98bd42b4734", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72ea28b0-b695-4847-8b76-01579e4b31e6"}}}]}, {"uuid": "a5e733fd-c2a1-42ae-a63b-4b11bfa9d4ad", "name": "load_p1rlv13058_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c83997dc-872f-494f-8c8a-7266c854fc48"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e9e358ae-8ebc-4bbc-aacf-73d7af4f2b43"}}}}, {"uuid": "fa7d9d10-6d78-4c79-8731-d4c36a133c7b", "name": "7d9a7113-b197-45a8-88c4-551125329b8a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.875608242018149, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1961787734858456, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7d1c59aa-705c-45c6-b82f-b7178e590441", "name": "a3343969-c521-4491-8340-33b943ea446a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fa7d9d10-6d78-4c79-8731-d4c36a133c7b"}}}]}, {"uuid": "fbd1c302-0e7e-41ea-8740-e1992463426f", "name": "load_p1rlv13058_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c83997dc-872f-494f-8c8a-7266c854fc48"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7d1c59aa-705c-45c6-b82f-b7178e590441"}}}}, {"uuid": "f0d8f92a-2aa8-4431-b312-ceb670228bc3", "name": "6e80263e-b0f6-4134-8069-1f1b7dbdc9d0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.516258392707745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.82351986644914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8d6d47de-9c11-42bd-853a-3d70debb739a", "name": "d4eb75ca-db27-4f11-a549-7e032883373b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f0d8f92a-2aa8-4431-b312-ceb670228bc3"}}}]}, {"uuid": "1c110a7c-5cdc-43a4-b1f8-747810ee5d26", "name": "load_p1rlv13059_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a1779b5b-1a6c-4511-9d4b-88026b430173"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8d6d47de-9c11-42bd-853a-3d70debb739a"}}}}, {"uuid": "8392a5f2-8483-4178-8754-587db4aabfb1", "name": "f1e5901c-94b7-463f-9101-552c870f7ba5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.516258392707745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.82351986644914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "818d8732-8073-4359-aa2a-4354c7097e22", "name": "3fd08c63-7fde-40fd-9774-52d88dda9756", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8392a5f2-8483-4178-8754-587db4aabfb1"}}}]}, {"uuid": "baecbf82-3a54-4bec-8e4f-b5150a2aaa5c", "name": "load_p1rlv13059_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a1779b5b-1a6c-4511-9d4b-88026b430173"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "818d8732-8073-4359-aa2a-4354c7097e22"}}}}, {"uuid": "4a61925b-63ad-4878-bc40-638e85e45994", "name": "5aa02a8b-c7a8-436e-a0a9-b6678a5c7f62_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3225810719994042, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7007930471414398, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1bfb56c0-4096-4c8c-8132-c0d23ee1f565", "name": "a962c033-de0a-49a5-938a-78efb020e111", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4a61925b-63ad-4878-bc40-638e85e45994"}}}]}, {"uuid": "a20be27f-4923-49db-83c7-31bc05844f05", "name": "load_p1rlv13060_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8767a040-da31-48d9-9473-0941856bcedc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1bfb56c0-4096-4c8c-8132-c0d23ee1f565"}}}}, {"uuid": "a0650809-8db7-442f-9baf-4b1823c29dac", "name": "11a2873e-9d09-40a4-88ec-071c2a439041_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3225810719994042, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7007930471414398, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "11e7c63b-d762-436a-ab74-35f68452aa97", "name": "c22d50fb-5daa-45ee-ae34-1913bc061277", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a0650809-8db7-442f-9baf-4b1823c29dac"}}}]}, {"uuid": "54f04642-4939-42fd-84ee-dc703d2e192c", "name": "load_p1rlv13060_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8767a040-da31-48d9-9473-0941856bcedc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "11e7c63b-d762-436a-ab74-35f68452aa97"}}}}, {"uuid": "f09616a9-d057-472b-be37-d3dde12abaa4", "name": "6818e893-548b-4084-ab88-2c7a3f9b4ae8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.20841006074213, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.2893238389393127, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "05d08ee4-9edf-462f-ab42-6f6ab946315a", "name": "6818e893-548b-4084-ab88-2c7a3f9b4ae8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.20841006074213, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.2893238389393127, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5b5f5f56-b919-4163-9f77-d0372d0dfc9c", "name": "6818e893-548b-4084-ab88-2c7a3f9b4ae8_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.20841006074213, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.2893238389393127, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7cbd7f03-3a65-4248-ac54-402c42382bd1", "name": "18abeb5f-69d6-4190-8139-c09f1ecb7b47", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f09616a9-d057-472b-be37-d3dde12abaa4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "05d08ee4-9edf-462f-ab42-6f6ab946315a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b5f5f56-b919-4163-9f77-d0372d0dfc9c"}}}]}, {"uuid": "aefdeb5a-7e28-4e59-a971-9e1880d00e58", "name": "load_p1rlv13061", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d46fd47-37f5-48a0-ba0d-d0746e6e6da3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7cbd7f03-3a65-4248-ac54-402c42382bd1"}}}}, {"uuid": "6a5e0cda-f071-41b3-89c3-bc3895ae79fd", "name": "0d619baf-e5ab-4247-ae0b-9be1dc720473_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c7020c42-d410-4138-b783-2833e5b95e5d", "name": "99999fa5-08e3-4da4-a649-53dbbd1068f7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6a5e0cda-f071-41b3-89c3-bc3895ae79fd"}}}]}, {"uuid": "95215704-3da1-4ebf-82f9-6059829ad086", "name": "load_p1rlv13062_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d2fa164-4c03-4bcd-a386-749ccd4e9001"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c7020c42-d410-4138-b783-2833e5b95e5d"}}}}, {"uuid": "46910cb5-2278-4ebc-b869-a4176999f6a2", "name": "8019d56f-4594-4922-9645-636324369ed9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "80fc95da-435d-45a0-a2c9-560a5a2f6aa0", "name": "27053b5a-0961-4ef7-a1fc-1cd4ecca27c1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "46910cb5-2278-4ebc-b869-a4176999f6a2"}}}]}, {"uuid": "b9c24b71-6e11-4019-8154-506058e4c412", "name": "load_p1rlv13062_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d2fa164-4c03-4bcd-a386-749ccd4e9001"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "80fc95da-435d-45a0-a2c9-560a5a2f6aa0"}}}}, {"uuid": "f455affc-aa35-47f2-9204-d82535afe51e", "name": "f7144831-4e15-4ed2-aedc-52b063299ed5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7083181921938193, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5666922324635131, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d410a840-d501-424e-866e-c57fd35ed41b", "name": "62e4edf4-f84f-4ca5-b758-65ce2968d898", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f455affc-aa35-47f2-9204-d82535afe51e"}}}]}, {"uuid": "e1bdea92-19fa-4287-b18d-26335d377399", "name": "load_p1rlv13185_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c29c3206-b71d-41d1-8ad7-a693c8c25d4d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d410a840-d501-424e-866e-c57fd35ed41b"}}}}, {"uuid": "2e60e5d6-561c-42b0-8601-c04b7998b6c8", "name": "352fe72c-c94f-441e-84ce-c82499836e28_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7083181921938193, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5666922324635131, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f4f3c19-5175-404f-9c92-e25705eb2ba8", "name": "defe891f-b26d-4dbc-9a31-c5346d2e5ce6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2e60e5d6-561c-42b0-8601-c04b7998b6c8"}}}]}, {"uuid": "38d145c4-18bd-4d9e-a258-5ecd2fd7429b", "name": "load_p1rlv13185_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c29c3206-b71d-41d1-8ad7-a693c8c25d4d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f4f3c19-5175-404f-9c92-e25705eb2ba8"}}}}, {"uuid": "cb8dd4b9-478e-47ca-9faa-4093149e4ba4", "name": "6d4551ec-1524-4d41-a79c-0698ba79ae98_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.774034588817963, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.005441618856208, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0367dad2-f61f-42d8-84b1-beb3a9f41e18", "name": "7ec19d5f-61eb-4752-b91e-7418eebc93a8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cb8dd4b9-478e-47ca-9faa-4093149e4ba4"}}}]}, {"uuid": "c488ff8d-b283-48e1-926a-a87c8c8c974d", "name": "load_p1rlv13187_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ffbd17b6-b1a2-4e55-9052-67a84419bb9d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0367dad2-f61f-42d8-84b1-beb3a9f41e18"}}}}, {"uuid": "44ac4961-909d-4886-bad7-ad68cddce4d2", "name": "b5cd8e31-7da9-43c0-a8b3-2d09ba56c7c0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.774034588817963, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.005441618856208, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "71866af3-3b03-49b5-8ed8-2fcb0c02fb5d", "name": "0a7ca848-f6e4-4330-b1ba-bcc12a3de282", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "44ac4961-909d-4886-bad7-ad68cddce4d2"}}}]}, {"uuid": "7f56d7c7-f838-4fcb-89c1-2d348c29a4c7", "name": "load_p1rlv13187_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ffbd17b6-b1a2-4e55-9052-67a84419bb9d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "71866af3-3b03-49b5-8ed8-2fcb0c02fb5d"}}}}, {"uuid": "90accc6c-537a-4e94-b3d9-599bc4d64d05", "name": "4038a0af-b705-4717-9396-d519d296d2bd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.028781788264419, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6709073147144231, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1f1260f7-8479-4de9-9e97-75aad039f9d2", "name": "b06a4187-870a-460c-b8eb-49f511949b47", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "90accc6c-537a-4e94-b3d9-599bc4d64d05"}}}]}, {"uuid": "abb8d875-6105-4ed3-8a3c-c50530500a31", "name": "load_p1rlv13188_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67ffcd9f-ba90-4da7-b3b6-46310e321590"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1f1260f7-8479-4de9-9e97-75aad039f9d2"}}}}, {"uuid": "3ed24d70-5c45-4cd8-92ce-2d822e741459", "name": "e40b61a4-2e7d-42de-a2ec-5134d7e60e86_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.028781788264419, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6709073147144231, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "66d43c17-fd3c-4cff-beed-d3cf878028df", "name": "908786ce-d194-4c28-a6cb-a687c3d12f93", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3ed24d70-5c45-4cd8-92ce-2d822e741459"}}}]}, {"uuid": "9719e5cb-9795-4a7a-bdea-f89f7f132c4c", "name": "load_p1rlv13188_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67ffcd9f-ba90-4da7-b3b6-46310e321590"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "66d43c17-fd3c-4cff-beed-d3cf878028df"}}}}, {"uuid": "749e6bd0-8c6d-4d4f-be52-4afd163f1e24", "name": "c9a3c089-66dc-4582-8ede-10c963e974e4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6702758059963014, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.7275069224848631, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dab591e8-b136-4923-a683-e9971efb1b7c", "name": "3fa3ab7c-8f40-43ca-9727-3fbeca5f3e7b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "749e6bd0-8c6d-4d4f-be52-4afd163f1e24"}}}]}, {"uuid": "7d6f4ffd-ea62-44ad-940b-8f4102b7b3c6", "name": "load_p1rlv13189_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "268361f6-d5ac-4002-80a6-f56f3b33599c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dab591e8-b136-4923-a683-e9971efb1b7c"}}}}, {"uuid": "9a5cacf7-835a-49cf-acd7-b750f5c58c18", "name": "ab341bf9-86dc-4140-a854-37cb7399eacb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6702758059963014, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.7275069224848631, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1012a10a-56cf-4ac9-9911-897ba8019bfb", "name": "44268273-eb53-429a-8f44-2a6a4a41b061", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9a5cacf7-835a-49cf-acd7-b750f5c58c18"}}}]}, {"uuid": "bca953e6-f28c-436e-b66c-e5009a64a975", "name": "load_p1rlv13189_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "268361f6-d5ac-4002-80a6-f56f3b33599c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1012a10a-56cf-4ac9-9911-897ba8019bfb"}}}}, {"uuid": "395a2561-b788-4737-9b64-e078b6546749", "name": "e3699a39-4ba1-4a3c-bf6d-2e51ffb98753_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.667455481738122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8122169683202977, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "35ed602a-8684-4906-8cc5-28d4667ee3d0", "name": "fecd8dfc-615e-4e60-aa7f-ad1c564bd08e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "395a2561-b788-4737-9b64-e078b6546749"}}}]}, {"uuid": "a2a392ac-8ce7-4c1f-89fb-f905f3fcfbc4", "name": "load_p1rlv13190_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3dbc593c-3949-4fa4-8738-d92540dbf998"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "35ed602a-8684-4906-8cc5-28d4667ee3d0"}}}}, {"uuid": "fafb4c38-c350-42f5-b9bf-65b115e4be2a", "name": "75db384a-c407-4fe0-b583-acac860ef089_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.667455481738122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8122169683202977, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "edb4253e-fdd3-411f-990e-16e38c36492c", "name": "5fca91c1-9303-45b0-9c0a-6a572f1e48a2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fafb4c38-c350-42f5-b9bf-65b115e4be2a"}}}]}, {"uuid": "f2da2ffb-270d-4757-bbf1-9064b5ccbad5", "name": "load_p1rlv13190_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3dbc593c-3949-4fa4-8738-d92540dbf998"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "edb4253e-fdd3-411f-990e-16e38c36492c"}}}}, {"uuid": "15e0ada5-9a29-4e07-97ec-108affc305b4", "name": "500052cb-f666-4032-a2b2-bab8b21a3486_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.921717825926216, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5520868751081406, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "34f6ee7b-b630-4c41-93d1-81d672c2eb6a", "name": "d32ebdcd-458d-46eb-809d-09c340eac5ad", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "15e0ada5-9a29-4e07-97ec-108affc305b4"}}}]}, {"uuid": "6ef49a1a-54aa-4ea5-b8ec-a869524870c2", "name": "load_p1rlv13191_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f6d09e9-3592-4560-8626-0d7cb71ca56a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "34f6ee7b-b630-4c41-93d1-81d672c2eb6a"}}}}, {"uuid": "b91f19a4-1fa5-42e2-bc4c-63d94394b78b", "name": "293b3bea-f770-484c-af08-4aa060d931cf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.921717825926216, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5520868751081406, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "21b89c3c-7d8f-44f2-be4c-2729adb154b6", "name": "855faf25-9d72-460b-81f3-1f2d5b31611a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b91f19a4-1fa5-42e2-bc4c-63d94394b78b"}}}]}, {"uuid": "13399b76-ec3f-4106-959d-3a94f7c1ce5f", "name": "load_p1rlv13191_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f6d09e9-3592-4560-8626-0d7cb71ca56a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "21b89c3c-7d8f-44f2-be4c-2729adb154b6"}}}}, {"uuid": "9feed621-db52-4acd-aa85-7f7d9f2ec289", "name": "cdbb55a3-b472-4d02-925d-3f772077109b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5300176124233262, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6781680527999017, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "048611e6-65d1-4c10-a692-96661c2a8918", "name": "d17a7a92-cbd8-4c79-9bdc-cc7740946c9b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9feed621-db52-4acd-aa85-7f7d9f2ec289"}}}]}, {"uuid": "4f0ccd3a-8be6-405b-985a-749cf90427ca", "name": "load_p1rlv13194_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d5ba889-d8f7-44ca-86b2-40939fa95df2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "048611e6-65d1-4c10-a692-96661c2a8918"}}}}, {"uuid": "2475c74c-94c4-46d5-8d6d-bac499071094", "name": "8e9d3c6d-fe0b-4f56-bb2b-6ce8739d7903_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5300176124233262, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6781680527999017, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "adda3498-b470-40e0-ad6d-84898623c771", "name": "d70c74cf-2de6-4495-8cb0-9eb84d9b96d0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2475c74c-94c4-46d5-8d6d-bac499071094"}}}]}, {"uuid": "e20cfae8-25b8-4116-9fe0-d5f20ebe404a", "name": "load_p1rlv13194_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d5ba889-d8f7-44ca-86b2-40939fa95df2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "adda3498-b470-40e0-ad6d-84898623c771"}}}}, {"uuid": "bbf7c688-0003-4d2e-8ecd-7359df36e721", "name": "c3def5f5-ec1e-4744-82c5-7166a5e86bde_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5670847441713207, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5540004468841006, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4abf7b78-c528-4955-94e5-48b90677531d", "name": "7880990d-bbf5-4fb9-98dc-41446ae0eaa8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bbf7c688-0003-4d2e-8ecd-7359df36e721"}}}]}, {"uuid": "5edc1716-e850-46c9-a684-263e46e62c9f", "name": "load_p1rlv13195_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e3e10c6-6ce2-4efa-be50-80e8b9bffe29"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4abf7b78-c528-4955-94e5-48b90677531d"}}}}, {"uuid": "02148270-d3f4-4c59-a2db-180eaa5f6e7d", "name": "0ab68643-d170-4d11-9c01-c0b81c3e2af2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5670847441713207, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5540004468841006, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2c5372b0-f45f-4a43-85e2-dde672b97a62", "name": "d1c9efd6-80e1-43dc-8b93-a1edd8d4263f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "02148270-d3f4-4c59-a2db-180eaa5f6e7d"}}}]}, {"uuid": "490acbcf-dec4-4965-9313-3498325efe09", "name": "load_p1rlv13195_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e3e10c6-6ce2-4efa-be50-80e8b9bffe29"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2c5372b0-f45f-4a43-85e2-dde672b97a62"}}}}, {"uuid": "6ae648fb-d09e-4c41-87e0-ca3a8d0da424", "name": "43c5e241-13d0-45b1-bce1-197bff3fa4ed_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.565985425671141, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8139237791533422, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "16e574a4-551a-4860-bf7f-1b8f4617b7ab", "name": "2875abd9-9f4b-4fcc-a8c8-6c53d49e4ae6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6ae648fb-d09e-4c41-87e0-ca3a8d0da424"}}}]}, {"uuid": "44c680a2-9eeb-4116-b0d5-0e2bba96cec1", "name": "load_p1rlv13196_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27013147-3d8f-4d75-a7a7-24457dc6d62a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "16e574a4-551a-4860-bf7f-1b8f4617b7ab"}}}}, {"uuid": "68149fca-3636-4d63-9aaf-a9776af7b4e5", "name": "7b062a3e-0dc2-44f1-8468-4e827b78a170_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.565985425671141, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8139237791533422, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "39d7fb73-eecd-4c90-a1b8-eea91fa80906", "name": "e2a1874f-f68a-4327-92c9-7c5bd349cba2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "68149fca-3636-4d63-9aaf-a9776af7b4e5"}}}]}, {"uuid": "18e6f764-9dc2-401a-aca6-387a640cb498", "name": "load_p1rlv13196_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27013147-3d8f-4d75-a7a7-24457dc6d62a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "39d7fb73-eecd-4c90-a1b8-eea91fa80906"}}}}, {"uuid": "cd3bf1f7-178e-4e37-af1c-71ee3fda84e2", "name": "8676102d-bd6e-4b64-8139-35261d0b516a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.88875250566531, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3533612733571443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3cb4cecc-fd03-46ca-8a7a-11f6d3c25706", "name": "6f4eef1e-5b06-427a-84e7-3dff9c0dd9ce", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cd3bf1f7-178e-4e37-af1c-71ee3fda84e2"}}}]}, {"uuid": "86dc39cd-37d2-4751-b049-62efd6d1d044", "name": "load_p1rlv13197_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b077d0f-74ec-4a04-8eb8-cf02ad16077d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3cb4cecc-fd03-46ca-8a7a-11f6d3c25706"}}}}, {"uuid": "00470f98-ca1d-4fe8-9eed-62ae6a5acb98", "name": "d9e8a415-8eb6-413a-bf6d-0d82fe874249_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.88875250566531, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3533612733571443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2d6ec1b4-1f84-43d0-a8f9-f697149b8cd9", "name": "65b56eab-9f11-4f42-820b-a98de379bc18", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "00470f98-ca1d-4fe8-9eed-62ae6a5acb98"}}}]}, {"uuid": "4941ce80-fbd4-4920-9b61-4a7973328dd5", "name": "load_p1rlv13197_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b077d0f-74ec-4a04-8eb8-cf02ad16077d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2d6ec1b4-1f84-43d0-a8f9-f697149b8cd9"}}}}, {"uuid": "d2d312dd-e429-44ee-b1da-478fe98a0d04", "name": "6b12e10f-4c38-48df-8729-363a813877c5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5401800544546385, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5525745253976501, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0e2ff513-8470-4dd8-bb10-1303f457ef6d", "name": "a4a5ac02-22f4-4b08-aa51-dd56d2eb35b5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d2d312dd-e429-44ee-b1da-478fe98a0d04"}}}]}, {"uuid": "ab52a8d9-56d7-4505-96f6-43958c808cbb", "name": "load_p1rlv13199_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad7545fb-8a41-4ed7-a178-e90f19bfa9d5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0e2ff513-8470-4dd8-bb10-1303f457ef6d"}}}}, {"uuid": "f5108d12-4535-409d-89cf-f89b367b6bb8", "name": "0c23895e-b538-43eb-9188-29f3b222bf8a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5401800544546385, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5525745253976501, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4024c612-bd14-466c-99e8-09f9b24f32bb", "name": "c2842eae-ba25-4847-bfa8-2fc534e875b6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f5108d12-4535-409d-89cf-f89b367b6bb8"}}}]}, {"uuid": "680b353e-4b9e-4cfd-8563-474184c7c4a4", "name": "load_p1rlv13199_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad7545fb-8a41-4ed7-a178-e90f19bfa9d5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4024c612-bd14-466c-99e8-09f9b24f32bb"}}}}, {"uuid": "5836d2d8-73bf-4713-aa19-2ebdb75d814e", "name": "3aa35252-4a62-4093-a046-1f26b5cccc96_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4622944887503224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10483650830237357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f3830231-d432-4ea1-a877-c43e1eb23c26", "name": "4406571f-ea0c-40d5-a95f-1d6ff0358e22", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5836d2d8-73bf-4713-aa19-2ebdb75d814e"}}}]}, {"uuid": "0cdce4ca-4ae0-4ef2-ab2e-21943cabf260", "name": "load_p1rlv13200_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fed30a3f-12a5-4545-b5d5-5c13a131a256"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f3830231-d432-4ea1-a877-c43e1eb23c26"}}}}, {"uuid": "24e9efc8-e540-453e-9c06-acb8376f8c87", "name": "e00d3e41-118b-4b67-9282-585e3a1062a6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4622944887503224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10483650830237357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e3e004c0-59f7-4008-bfc3-b21a8a3c2ec1", "name": "e944d3f7-b958-4ad8-babc-f3b650222041", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "24e9efc8-e540-453e-9c06-acb8376f8c87"}}}]}, {"uuid": "5cbfb4b6-8fe8-4226-9c2b-6a740d74a7dc", "name": "load_p1rlv13200_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fed30a3f-12a5-4545-b5d5-5c13a131a256"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e3e004c0-59f7-4008-bfc3-b21a8a3c2ec1"}}}}, {"uuid": "bf2b6285-13cf-417c-9019-df8d6d921784", "name": "72893fec-4075-4f0c-8439-ec735f3c3781_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.195601026095605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4379463760124337, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0690c0af-36e8-4faf-9931-a3452f52186f", "name": "b34d8a4c-b257-436f-8c55-a9c836295b91", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bf2b6285-13cf-417c-9019-df8d6d921784"}}}]}, {"uuid": "3c26dedc-4fc5-4269-ac0d-51bb1fe00d43", "name": "load_p1rlv13201_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cdd7c49-e758-4009-8db5-d0b5748f919c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0690c0af-36e8-4faf-9931-a3452f52186f"}}}}, {"uuid": "0381ba9f-4f61-4e8b-8f3e-33df9c63f2be", "name": "9255e6bf-8dac-41ed-818f-a3af6456b1a5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.195601026095605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4379463760124337, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1bb6d719-9f60-4715-acf7-328790d4356c", "name": "9c0ddcdd-a56e-4be5-a7dd-f0299fc3231b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0381ba9f-4f61-4e8b-8f3e-33df9c63f2be"}}}]}, {"uuid": "95beee2e-b0cd-4efd-a08f-b5aa0d3b96a2", "name": "load_p1rlv13201_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cdd7c49-e758-4009-8db5-d0b5748f919c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1bb6d719-9f60-4715-acf7-328790d4356c"}}}}, {"uuid": "f03edf52-7271-4a3e-ae1f-53a895760067", "name": "acb7d454-6f87-41e9-9a36-d2c551b386b6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8140414184691503, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34693077623207685, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7fe60fff-7fd7-4d9d-9182-8c33ae3cc32f", "name": "dab218dc-48d1-42fd-97bc-69e46edfd8ee", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f03edf52-7271-4a3e-ae1f-53a895760067"}}}]}, {"uuid": "9702e0ce-9c9a-4469-a0a1-a78d4c62d7f2", "name": "load_p1rlv13316_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473b080b-1412-40dc-a452-09d43a462098"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7fe60fff-7fd7-4d9d-9182-8c33ae3cc32f"}}}}, {"uuid": "3d64967f-5c6c-4c44-baff-4cea9d9023d4", "name": "ee63e168-4c6b-458f-9279-3f5f3a415f27_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8140414184691503, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34693077623207685, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d71051fc-5760-4907-b6d4-890667fc0d5b", "name": "048ee0ab-8d53-47d7-b9ed-62a8e4068d7b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3d64967f-5c6c-4c44-baff-4cea9d9023d4"}}}]}, {"uuid": "b6dbfe6e-a255-4b3a-b58c-e03141eab622", "name": "load_p1rlv13316_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473b080b-1412-40dc-a452-09d43a462098"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d71051fc-5760-4907-b6d4-890667fc0d5b"}}}}, {"uuid": "dac1c5ce-10b4-4584-9591-5e05bef98c5d", "name": "937de26d-9b11-4d11-ab4a-279351ae6c89_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a0c87f0-5315-4a11-85e7-c6b554c99a2b", "name": "fcf85268-ac67-4816-9093-b27b458df88f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dac1c5ce-10b4-4584-9591-5e05bef98c5d"}}}]}, {"uuid": "edc77fc3-e069-4d18-96c9-61760d32f742", "name": "load_p1rlv13597_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "353889fb-da44-4cf8-ae0e-d20541f36d7e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0a0c87f0-5315-4a11-85e7-c6b554c99a2b"}}}}, {"uuid": "26e8b0dc-2ac3-4742-ac43-55c0bb67b561", "name": "e0a5dbc6-77a6-4835-998c-1543298e0f8f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d9e348bd-8fff-4da1-98f1-8a90ff9da829", "name": "7ac170e6-bc12-4fef-b7e3-5c414b03ece6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "26e8b0dc-2ac3-4742-ac43-55c0bb67b561"}}}]}, {"uuid": "1d33447a-cabc-4c04-8811-f06c7603e54e", "name": "load_p1rlv13597_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "353889fb-da44-4cf8-ae0e-d20541f36d7e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d9e348bd-8fff-4da1-98f1-8a90ff9da829"}}}}, {"uuid": "37c4d4ed-d4bc-46ee-b908-0a71a5aa6518", "name": "800bea90-02ed-4d86-a2d7-34d14bf5aad6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "041a363b-8459-4191-a6f5-4685aeb8936b", "name": "ecc00417-30b1-427f-a6f3-81ae9febefaf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "37c4d4ed-d4bc-46ee-b908-0a71a5aa6518"}}}]}, {"uuid": "6033b316-93cf-415e-841e-82f4e21dbc25", "name": "load_p1rlv13598_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59953c2f-244e-4bb8-ab24-b28d82b195e1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "041a363b-8459-4191-a6f5-4685aeb8936b"}}}}, {"uuid": "c7f4cc2e-d190-4b9b-82c7-99a025144f6e", "name": "3e28f879-bbd7-4454-b56a-0e32fb67f207_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4913cce6-590b-4348-900a-b797faf546fd", "name": "20331403-4b6e-4cf2-837a-2862b0536e98", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c7f4cc2e-d190-4b9b-82c7-99a025144f6e"}}}]}, {"uuid": "63dca524-7496-41cc-9c8c-adcfbbe727bc", "name": "load_p1rlv13598_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59953c2f-244e-4bb8-ab24-b28d82b195e1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4913cce6-590b-4348-900a-b797faf546fd"}}}}, {"uuid": "c88ab96a-c49c-422b-bfd3-498b6fc68c01", "name": "1e50911e-2f5c-4f91-8819-6bbb0a799416_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cb268438-07b7-4715-968d-4f6ab65bcc52", "name": "49bf7cd1-6dfb-4119-b3d1-0f9ba6162d72", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c88ab96a-c49c-422b-bfd3-498b6fc68c01"}}}]}, {"uuid": "9be21e16-3c8d-4128-ab14-c6911cd8c684", "name": "load_p1rlv13599_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2a60818-4310-4100-9aa8-35ef37aa5f40"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cb268438-07b7-4715-968d-4f6ab65bcc52"}}}}, {"uuid": "bfcd7e85-efbc-4cfa-b47b-9ae669d6966c", "name": "bc0bb68d-ed14-4e89-9996-9bb3483c92c5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5e70eb0d-153f-4fb3-a538-2b0c4a1dc9fc", "name": "c3e6a5e6-3a47-4917-9dba-1bb6074677eb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bfcd7e85-efbc-4cfa-b47b-9ae669d6966c"}}}]}, {"uuid": "bdc775ec-84d1-4a2c-bb98-c1e19e71da3c", "name": "load_p1rlv13599_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2a60818-4310-4100-9aa8-35ef37aa5f40"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5e70eb0d-153f-4fb3-a538-2b0c4a1dc9fc"}}}}, {"uuid": "86a1a85e-300d-4da9-84ff-1fe5a2e5461f", "name": "c7009d2b-05c2-440b-b854-afa1d3a88ecb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.940151571607843, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7360323556900852, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3b91ff6a-d898-4df2-b1d2-53ce9e03bb81", "name": "348b7989-2c3f-46ef-b687-739cb14395a3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "86a1a85e-300d-4da9-84ff-1fe5a2e5461f"}}}]}, {"uuid": "e17443e8-f800-420d-803b-6bd11600508f", "name": "load_p1rlv13600_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59ab6d81-a91c-4350-8f94-abe02e3e1555"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3b91ff6a-d898-4df2-b1d2-53ce9e03bb81"}}}}, {"uuid": "34d0ec8c-f568-4d5b-81ed-0a449f709d4e", "name": "61bad4c4-8759-486c-8089-62cce9f8522a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.940151571607843, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7360323556900852, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "928b9698-5fd4-4dcb-b44f-e91ba1da74bc", "name": "e1242757-0cfe-4113-96b9-c8744221d741", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "34d0ec8c-f568-4d5b-81ed-0a449f709d4e"}}}]}, {"uuid": "7ecbba76-6fc2-4902-8f7e-ed8a8223ba90", "name": "load_p1rlv13600_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59ab6d81-a91c-4350-8f94-abe02e3e1555"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "928b9698-5fd4-4dcb-b44f-e91ba1da74bc"}}}}, {"uuid": "95ebc42e-d8ed-4efc-9e8d-d01fdf170ded", "name": "0ceedc81-bfb3-4288-961c-0e49525bf1d9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.872515319591797, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7328111219910317, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bf6f99c3-a9c4-4e4b-820c-a2e12bfe4966", "name": "f3195a99-0a13-4b39-8ab3-dc1c65446089", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "95ebc42e-d8ed-4efc-9e8d-d01fdf170ded"}}}]}, {"uuid": "fb643b41-122e-4bf0-b101-29d55e2bc232", "name": "load_p1rlv13601_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91953a27-bbc7-494a-bec2-a12b4c0f6af6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bf6f99c3-a9c4-4e4b-820c-a2e12bfe4966"}}}}, {"uuid": "07ad6e5f-b4ba-43fc-8288-53ecc9792bdd", "name": "b9747aa8-2e9e-4db4-94d7-2b04e560536a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.872515319591797, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7328111219910317, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "51667fa2-0da1-4cca-ad8a-6a60cfc43683", "name": "4cef8fd1-a3ff-4f2b-abb8-d9bcf4da4242", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "07ad6e5f-b4ba-43fc-8288-53ecc9792bdd"}}}]}, {"uuid": "b5b4f2e8-4da2-4bb5-9f06-43efb167b2a9", "name": "load_p1rlv13601_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91953a27-bbc7-494a-bec2-a12b4c0f6af6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "51667fa2-0da1-4cca-ad8a-6a60cfc43683"}}}}, {"uuid": "ea1ce7af-6d0a-423b-bc32-74905847c262", "name": "b61e5da4-890c-407d-a6f0-8fd358dda581_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.308477864741614, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307751830484037, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a45011c6-1d24-462b-99f0-9537120e1f35", "name": "614283b0-7844-438c-9863-4124f7dfc777", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ea1ce7af-6d0a-423b-bc32-74905847c262"}}}]}, {"uuid": "5402fdc5-a823-41d7-9db4-622ed2bf74bf", "name": "load_p1rlv13604_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9b83bdf-b564-4997-bfc7-1be2f2e58199"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a45011c6-1d24-462b-99f0-9537120e1f35"}}}}, {"uuid": "7378b82f-38ce-4c28-a550-c37b78d7b46c", "name": "86fa24a9-15a6-4d02-b561-bb5e1e8eba63_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.308477864741614, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307751830484037, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "13368055-1611-4a68-a552-3ecc6be93c50", "name": "58a60a73-ac22-4a59-9aa9-d024c3804259", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7378b82f-38ce-4c28-a550-c37b78d7b46c"}}}]}, {"uuid": "6c4e0cf3-fbb2-48bd-a319-e909a6b7afdc", "name": "load_p1rlv13604_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9b83bdf-b564-4997-bfc7-1be2f2e58199"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "13368055-1611-4a68-a552-3ecc6be93c50"}}}}, {"uuid": "96374ea5-49ab-4bb4-9b0f-e042b6f86caf", "name": "d2525f13-738e-4d5c-8557-092bc2a7aea9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0263288002917053, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.546221099657035, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6ac379df-438b-4c9a-9cee-907cb9ac2b96", "name": "d690a139-4ae2-45e1-9f14-79bf3d186cd3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "96374ea5-49ab-4bb4-9b0f-e042b6f86caf"}}}]}, {"uuid": "aa4e9307-1124-451d-bab1-24bd64df40db", "name": "load_p1rlv13605_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c39dc6f1-08b5-4bc1-a6ae-be0076af56aa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6ac379df-438b-4c9a-9cee-907cb9ac2b96"}}}}, {"uuid": "30529f9d-37bc-4c22-9856-0356ce450b19", "name": "2d6e29aa-c304-4568-a7ce-9e4ceaebc081_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0263288002917053, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.546221099657035, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "232736c1-342b-4abb-815a-85de36131904", "name": "cbb570ad-e05a-49e4-af04-6f5c1e6881c1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "30529f9d-37bc-4c22-9856-0356ce450b19"}}}]}, {"uuid": "88f60a05-1c81-46dc-b19b-d233db420470", "name": "load_p1rlv13605_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c39dc6f1-08b5-4bc1-a6ae-be0076af56aa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "232736c1-342b-4abb-815a-85de36131904"}}}}, {"uuid": "263e7d44-927e-42de-9b33-bc043e89c1c4", "name": "9a2d242b-b087-4c69-8f6d-278d9910f3d0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3058115791316, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6614039959360709, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3da29d94-7b41-43c1-93a6-dfa9f53858d7", "name": "9aa3ae61-c7b5-47b7-aa9d-5c8c80616f35", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "263e7d44-927e-42de-9b33-bc043e89c1c4"}}}]}, {"uuid": "513733d5-ddd6-4f64-84e2-3b9839127ace", "name": "load_p1rlv13606_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29838633-5c95-4b73-8227-cfa7f4aedc32"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3da29d94-7b41-43c1-93a6-dfa9f53858d7"}}}}, {"uuid": "c3508a5a-022c-43f9-9b4e-2ae2096aaa94", "name": "2aab3bd4-5cf8-4bcd-8736-1ba0c8b52714_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3058115791316, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6614039959360709, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "db7406f9-285f-4b88-a7df-591a5a6e057e", "name": "7e72a4ff-304d-46fd-b528-4db1ec619d00", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c3508a5a-022c-43f9-9b4e-2ae2096aaa94"}}}]}, {"uuid": "c3367ac3-ed0f-4f82-9322-d35372941dad", "name": "load_p1rlv13606_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29838633-5c95-4b73-8227-cfa7f4aedc32"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "db7406f9-285f-4b88-a7df-591a5a6e057e"}}}}, {"uuid": "d7118512-4d9f-4803-a23a-381c995f83d5", "name": "8f5f7a71-ef92-4554-b3f5-ec6859e30f41_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a684586-7b36-4a30-97ad-40077a5b1a2a", "name": "8bd626f0-1c1f-4b3d-97d1-a826eba24e2a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d7118512-4d9f-4803-a23a-381c995f83d5"}}}]}, {"uuid": "e224fb14-299d-47f6-9ef1-eda559eb944e", "name": "load_p1rlv13608_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5e8caf4-4d81-4bbd-98df-6622c5ad0563"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a684586-7b36-4a30-97ad-40077a5b1a2a"}}}}, {"uuid": "28630b53-5791-4151-9f80-b012654e5bbe", "name": "22d967d4-e19a-4c1e-8516-2630a06cb526_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "17a1254d-30de-4ff2-9c67-8f9c56bcdcdb", "name": "b8b4fca4-7ce8-4b31-8cea-14e2ee0c4126", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "28630b53-5791-4151-9f80-b012654e5bbe"}}}]}, {"uuid": "9e615355-12ee-4e44-8d83-55496ef1fcf3", "name": "load_p1rlv13608_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5e8caf4-4d81-4bbd-98df-6622c5ad0563"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "17a1254d-30de-4ff2-9c67-8f9c56bcdcdb"}}}}, {"uuid": "1feccc53-8a55-4dc6-9f14-4cf6e7aeebdc", "name": "8e9ec97c-4e8e-477f-ae8c-95e2d6519669_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5204227867871802, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7134940441409878, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "efc5b363-454a-4a41-938c-d9814f2c1f71", "name": "56b8d8b3-7160-498a-adf8-e9d5489fc83e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1feccc53-8a55-4dc6-9f14-4cf6e7aeebdc"}}}]}, {"uuid": "db709395-c523-49cd-bc4c-951458b96c38", "name": "load_p1rlv13610_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17d92377-b4f1-4194-89cd-130bddb9b77c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "efc5b363-454a-4a41-938c-d9814f2c1f71"}}}}, {"uuid": "3d4a40ad-cf2f-48cc-91b8-c510fcfd720a", "name": "2f6e39fc-02dc-4ced-b0c9-d2e034212c8b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5204227867871802, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7134940441409878, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "22cf121f-0a5e-4231-a163-421c123a468b", "name": "ac3812fd-6712-48ea-a30a-3a72ae609341", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3d4a40ad-cf2f-48cc-91b8-c510fcfd720a"}}}]}, {"uuid": "30ca95f8-c26e-4560-b35e-048e5962d8eb", "name": "load_p1rlv13610_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17d92377-b4f1-4194-89cd-130bddb9b77c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "22cf121f-0a5e-4231-a163-421c123a468b"}}}}, {"uuid": "a9e4bce4-e5ea-4dbe-9c8b-0996a5871289", "name": "b0ee7b25-6a5f-4828-bb53-791e41cee671_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2489699911360574, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6200743429841856, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ace91704-0ee2-4020-8008-431ae1f26054", "name": "eebf7c81-db20-425a-8370-c45b1c52bb94", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a9e4bce4-e5ea-4dbe-9c8b-0996a5871289"}}}]}, {"uuid": "2f7690c2-b063-4a26-95de-fd6e37f8f5e8", "name": "load_p1rlv13611_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "630b2a63-622f-4f78-8390-77c69ba7e393"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ace91704-0ee2-4020-8008-431ae1f26054"}}}}, {"uuid": "38d953b6-3f7b-4e8e-be9a-ae293ecbf7d8", "name": "42816fc3-6691-4291-a26a-fc09ab7e3bc0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2489699911360574, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6200743429841856, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5dd03872-be94-4cdd-a533-e296b0ac4845", "name": "594456f4-453a-4fc6-af35-02d1f8ae5882", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "38d953b6-3f7b-4e8e-be9a-ae293ecbf7d8"}}}]}, {"uuid": "911a5c75-08be-456c-973b-9a4c69d19096", "name": "load_p1rlv13611_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "630b2a63-622f-4f78-8390-77c69ba7e393"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5dd03872-be94-4cdd-a533-e296b0ac4845"}}}}, {"uuid": "ceabb95c-76b6-47da-a2a5-4e08546fcc2b", "name": "025048b4-8552-4dc2-9bb0-12431180acd8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0788570276665777, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5949433355568994, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e582b791-1f79-4fe0-9652-895edb6344c8", "name": "d53d11c2-17ce-4f3c-a9fd-6078dad4bbd9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ceabb95c-76b6-47da-a2a5-4e08546fcc2b"}}}]}, {"uuid": "61c13545-2cec-4589-b92e-12a351832386", "name": "load_p1rlv13612_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6eda3e97-a618-41ab-ae55-ba67f6bb0234"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e582b791-1f79-4fe0-9652-895edb6344c8"}}}}, {"uuid": "38891ee9-4cab-4112-95d0-c271e8712dac", "name": "2a6196bf-11e5-4c12-ae76-cd971eb48e56_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0788570276665777, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5949433355568994, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2c0dfc31-f7c5-448a-b043-29789cc89020", "name": "7df2e922-0b73-4fa6-9815-4813fb83d211", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "38891ee9-4cab-4112-95d0-c271e8712dac"}}}]}, {"uuid": "950cc650-04a5-4d24-bcbe-53ff2c5a8a71", "name": "load_p1rlv13612_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6eda3e97-a618-41ab-ae55-ba67f6bb0234"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2c0dfc31-f7c5-448a-b043-29789cc89020"}}}}, {"uuid": "615db8c4-a370-422f-8b4d-781af51be9d4", "name": "ef027f39-0c3c-4bc3-8c3f-55acd3dc42f9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4038244377730775, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.30842299757959857, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "577b1b4d-48de-488a-b861-edbf0baf30ba", "name": "05b1a662-a415-49ce-a317-1d02d95e6738", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "615db8c4-a370-422f-8b4d-781af51be9d4"}}}]}, {"uuid": "dd4d943d-5659-4a56-b23f-4c946dda2361", "name": "load_p1rlv13613_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "216537dd-ea7b-461c-b821-99491c41b7f0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "577b1b4d-48de-488a-b861-edbf0baf30ba"}}}}, {"uuid": "5dc94bd8-c89f-4a2d-89cb-5ec7d3fd4fd5", "name": "a779b030-b0ef-4643-9c38-2a0b46685b34_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4038244377730775, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.30842299757959857, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "099b682b-fba1-4215-bfcf-8fc8cec8d482", "name": "858472de-7dc6-4d68-b184-da80b2f6fe29", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5dc94bd8-c89f-4a2d-89cb-5ec7d3fd4fd5"}}}]}, {"uuid": "3c640205-45c4-40ae-9e42-96ac27b81452", "name": "load_p1rlv13613_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "216537dd-ea7b-461c-b821-99491c41b7f0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "099b682b-fba1-4215-bfcf-8fc8cec8d482"}}}}, {"uuid": "c401073b-65fd-4fcc-a753-63093a15d2a7", "name": "aa64dd19-278b-4f71-b580-5e4a6d3dd375_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8b433e2b-9be7-4845-9f80-726834f5e0a3", "name": "80429f8b-4518-49fa-821e-18823aba8c08", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c401073b-65fd-4fcc-a753-63093a15d2a7"}}}]}, {"uuid": "513e3258-3983-4da3-bcc3-6daa810f2225", "name": "load_p1rlv13614_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3de8b994-01ba-4eae-b9cf-7fb174d32355"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8b433e2b-9be7-4845-9f80-726834f5e0a3"}}}}, {"uuid": "c8bf0b27-96cd-421f-8407-d565d173abd1", "name": "da73a03b-3f48-4f38-9384-ac4f10889abd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "650cf6ba-fe0c-4878-b263-0128aa0144d0", "name": "5a5810e9-1f98-404f-a07c-e1219374cffa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c8bf0b27-96cd-421f-8407-d565d173abd1"}}}]}, {"uuid": "7406de4a-2f49-4d2a-8c76-cafbe9ba85c2", "name": "load_p1rlv13614_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3de8b994-01ba-4eae-b9cf-7fb174d32355"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "650cf6ba-fe0c-4878-b263-0128aa0144d0"}}}}, {"uuid": "c661fa66-2f5a-43d5-99bf-3ff16796aaed", "name": "c0e4c6b3-3279-479f-ac5d-8dc382c17966_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5937162117629007, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7166618655640316, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7153f498-dbb9-489e-b8e7-8f16d884d4c2", "name": "e9e9f350-68d2-45c2-ba4d-47d5bba6f8e0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c661fa66-2f5a-43d5-99bf-3ff16796aaed"}}}]}, {"uuid": "f9a7de0e-1624-4e03-a4d4-0bf885f4db72", "name": "load_p1rlv13616_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "850d5b69-14cf-4a18-8cb0-4f1b3033b0aa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7153f498-dbb9-489e-b8e7-8f16d884d4c2"}}}}, {"uuid": "84568431-202f-46d3-a1a7-6cf36056966d", "name": "4c3f9928-dd45-4c08-8226-a9af82946f53_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5937162117629007, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7166618655640316, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4ff9e464-1d53-4124-aa0c-1d94088c75da", "name": "f60b7063-cd28-448b-8075-e90671f50e66", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "84568431-202f-46d3-a1a7-6cf36056966d"}}}]}, {"uuid": "63f4474e-0953-4d5e-b2d1-64cf24a77cc6", "name": "load_p1rlv13616_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "850d5b69-14cf-4a18-8cb0-4f1b3033b0aa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4ff9e464-1d53-4124-aa0c-1d94088c75da"}}}}, {"uuid": "0243729f-a4f3-4b56-a9ab-92767d1d70a5", "name": "6358a027-9c78-4156-8d36-a3bb6ae9dea7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.32403643380503, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6293121819683343, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ec564e10-1096-40d1-aabf-086dcfce9ad1", "name": "bfbd1fab-efe8-4742-9ec7-e067bf5b8101", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0243729f-a4f3-4b56-a9ab-92767d1d70a5"}}}]}, {"uuid": "9d936c16-a4ef-41d3-a02b-81a91da4ab6f", "name": "load_p1rlv13618_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f823a90c-effd-489c-9e0a-c110ccb7b9e8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ec564e10-1096-40d1-aabf-086dcfce9ad1"}}}}, {"uuid": "982da60c-87b4-4c34-ab26-f5fc1800475c", "name": "7d175011-18a2-48ee-9860-86faf3a84ead_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.32403643380503, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6293121819683343, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a60f819f-3886-44bb-b377-d01b1a10dbb7", "name": "b5976cb3-6e35-4410-b95d-deb0d34c43e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "982da60c-87b4-4c34-ab26-f5fc1800475c"}}}]}, {"uuid": "ecfe68a2-0142-4266-a254-a2845e55b700", "name": "load_p1rlv13618_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f823a90c-effd-489c-9e0a-c110ccb7b9e8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a60f819f-3886-44bb-b377-d01b1a10dbb7"}}}}, {"uuid": "1a69abb9-b58e-4d90-82f6-eb37166b9bd1", "name": "8fb1d5ac-e728-4989-a7bc-cee6ea816c78_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f3a8970e-e470-4043-80aa-fb20167e1294", "name": "5abaf938-70c7-4202-81f3-18640982dbd3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1a69abb9-b58e-4d90-82f6-eb37166b9bd1"}}}]}, {"uuid": "81bfac05-e086-4de0-83c9-c6e2a05cc9a7", "name": "load_p1rlv13619_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f693a1d2-5499-4810-9458-f205eda265fa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f3a8970e-e470-4043-80aa-fb20167e1294"}}}}, {"uuid": "26cc3290-18c5-492c-a8b9-e11d1ac7ae2b", "name": "d10fdde6-9faf-436f-8462-ad79941e50fd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50973f29-fe75-4d0e-9ddb-b975772b2ce8", "name": "afdb77a0-c05b-4936-8e17-42daaec74c50", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "26cc3290-18c5-492c-a8b9-e11d1ac7ae2b"}}}]}, {"uuid": "9e9747fe-1fab-4906-80cc-2990dc64a58d", "name": "load_p1rlv13619_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f693a1d2-5499-4810-9458-f205eda265fa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50973f29-fe75-4d0e-9ddb-b975772b2ce8"}}}}, {"uuid": "540b6425-7b6a-418a-9407-b741ccfbc1f0", "name": "331275d4-11df-4025-bd14-639b10811382_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3711169311548215, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.698133467399761, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dd8c0a0d-94a1-4a22-8ae4-7f99f1e72767", "name": "cba0580c-e34b-4136-934a-1954c8bef28e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "540b6425-7b6a-418a-9407-b741ccfbc1f0"}}}]}, {"uuid": "cd00aa99-b5c4-414d-8e55-6ec7ae7ed2cf", "name": "load_p1rlv13622_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4540b2cb-ee21-4515-a7ca-fbca371f060d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dd8c0a0d-94a1-4a22-8ae4-7f99f1e72767"}}}}, {"uuid": "b69fd5c7-dfe1-4a99-bafc-eeaa6547cdde", "name": "b932ded9-91ac-49b2-9cf7-60be0a24b0de_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3711169311548215, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.698133467399761, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b511ff2f-d16a-4da3-8c26-026b36bcf320", "name": "81520e07-1b5e-47f8-831d-fbc974227fc0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b69fd5c7-dfe1-4a99-bafc-eeaa6547cdde"}}}]}, {"uuid": "be39051c-160a-4255-82db-c4f94178fc78", "name": "load_p1rlv13622_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4540b2cb-ee21-4515-a7ca-fbca371f060d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b511ff2f-d16a-4da3-8c26-026b36bcf320"}}}}, {"uuid": "16db1fde-6327-40dc-b52c-9f4a9422dcab", "name": "b644319d-53f3-449a-8718-b090f40475ed_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6a2b4aa1-0e89-41f0-b2ee-237b8b4595cb", "name": "3194b37e-7435-4ed6-af61-d734630c7a8b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "16db1fde-6327-40dc-b52c-9f4a9422dcab"}}}]}, {"uuid": "823d3c38-d418-44a7-b3e7-990cef254e23", "name": "load_p1rlv13623_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80f60ab3-722f-4765-8b91-4fd0196171d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6a2b4aa1-0e89-41f0-b2ee-237b8b4595cb"}}}}, {"uuid": "6abe6328-7df4-44da-be3e-ba9d24e13cf2", "name": "5663592a-6245-44f0-8eec-b827b8056d8e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "386b9a03-f06a-44a2-8c0a-a07514b3e02c", "name": "efd73571-4bdf-4f76-8caa-8ca5bc2e86ce", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6abe6328-7df4-44da-be3e-ba9d24e13cf2"}}}]}, {"uuid": "a548b0cf-d329-424c-9939-c106e24fd913", "name": "load_p1rlv13623_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80f60ab3-722f-4765-8b91-4fd0196171d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "386b9a03-f06a-44a2-8c0a-a07514b3e02c"}}}}, {"uuid": "6353637a-3b3c-4a60-98ca-da3849ffab62", "name": "83606068-7e13-44f5-bd59-8eb99d849b7e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.611133182200907, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.07668264048246332, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5e111da4-7213-4700-aef8-69237ad31af7", "name": "55b70704-76f8-4604-abe8-e6358eb78676", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6353637a-3b3c-4a60-98ca-da3849ffab62"}}}]}, {"uuid": "87bf233e-57f9-4173-b00a-ad70cdf98074", "name": "load_p1rlv13624_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a5746d1-24a6-4ae4-b5dc-cef23b56660d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5e111da4-7213-4700-aef8-69237ad31af7"}}}}, {"uuid": "e7d644a0-c392-4633-988e-6be09deff0c3", "name": "035df44e-9561-422c-998f-a75dbe9ae4d4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.611133182200907, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.07668264048246332, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dd42cc15-e607-43c0-abb3-28e853c03221", "name": "fd2bc551-42c3-4ced-98c1-ba15d124bc6f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e7d644a0-c392-4633-988e-6be09deff0c3"}}}]}, {"uuid": "32fa6b51-eaaf-436a-bf91-636c328ee365", "name": "load_p1rlv13624_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a5746d1-24a6-4ae4-b5dc-cef23b56660d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dd42cc15-e607-43c0-abb3-28e853c03221"}}}}, {"uuid": "de0e49fe-3bdc-4a7d-b7d7-8338ab3dd376", "name": "777e7565-5332-4b34-962b-6a3114ca9330_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "900c9dcb-6b50-42ef-b05e-f4269e808dc3", "name": "ff4eb721-cb89-4c0e-8201-228b68fcbabe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "de0e49fe-3bdc-4a7d-b7d7-8338ab3dd376"}}}]}, {"uuid": "2706875b-9294-4ba4-bf0e-031c0118dbcc", "name": "load_p1rlv13625_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c667408-52a0-4258-8e93-557c94520a1e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "900c9dcb-6b50-42ef-b05e-f4269e808dc3"}}}}, {"uuid": "3ca686af-a312-424b-ad0a-a2857bea5608", "name": "da0f3f06-1012-4b11-b775-12810257b6b1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dbf022ae-cc92-42fb-80a6-57b5f4af35c9", "name": "e78818ab-c2d2-45d7-8e49-4178d541aa87", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3ca686af-a312-424b-ad0a-a2857bea5608"}}}]}, {"uuid": "3f8f8afb-ed05-41b4-b003-9dbd2533152e", "name": "load_p1rlv13625_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c667408-52a0-4258-8e93-557c94520a1e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dbf022ae-cc92-42fb-80a6-57b5f4af35c9"}}}}, {"uuid": "b5b8ebb5-3bad-4a3e-9274-6b3fe9628924", "name": "0d3c68fa-98b9-4457-9623-b2ddbef6bad9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2167250892906645, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5534364726692191, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "495030ab-3b27-4d33-b025-282b4b044338", "name": "2b498706-f03c-4f51-be0e-276bb22b8961", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5b8ebb5-3bad-4a3e-9274-6b3fe9628924"}}}]}, {"uuid": "56acabce-8878-49c1-b94c-af9220f4e454", "name": "load_p1rlv13626_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aeea20e0-9908-4f28-aa5d-068244e3861b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "495030ab-3b27-4d33-b025-282b4b044338"}}}}, {"uuid": "60e32a94-a8bc-42dd-8a92-eba24c87b680", "name": "b56423f4-655b-404a-9ed5-c661669886fd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2167250892906645, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5534364726692191, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1d65980a-33fe-4dfd-9088-9855d7e3a557", "name": "6243df8a-9e5d-47cb-b112-436fe69e32bd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "60e32a94-a8bc-42dd-8a92-eba24c87b680"}}}]}, {"uuid": "94ea13bc-304f-49d4-84d0-97ddf66b1fba", "name": "load_p1rlv13626_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aeea20e0-9908-4f28-aa5d-068244e3861b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1d65980a-33fe-4dfd-9088-9855d7e3a557"}}}}, {"uuid": "2ebe26fa-10b8-4996-a592-cf2d510877fc", "name": "fd6b2f83-f55c-4178-84d4-25f825f42afc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "29d57d91-dfb5-45cd-8116-2ed75b39201d", "name": "b9a16346-3061-4545-8663-f33e340b22b3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2ebe26fa-10b8-4996-a592-cf2d510877fc"}}}]}, {"uuid": "a9f67b6f-8541-4045-be0d-ac8ec292b43e", "name": "load_p1rlv13627_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bd69c55-2141-4c8e-becf-efa4bff8a63e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "29d57d91-dfb5-45cd-8116-2ed75b39201d"}}}}, {"uuid": "d390e1cb-6ad3-4c4e-8727-81af1319dbf9", "name": "e001b741-a080-4706-be40-76b9d706fd05_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aaccb708-0a7f-4541-9e29-2794fd6b3222", "name": "689efcce-d483-476d-8917-ae96f946d395", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d390e1cb-6ad3-4c4e-8727-81af1319dbf9"}}}]}, {"uuid": "1fe6206e-10f8-4593-a6d9-66b3a1e11005", "name": "load_p1rlv13627_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bd69c55-2141-4c8e-becf-efa4bff8a63e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aaccb708-0a7f-4541-9e29-2794fd6b3222"}}}}, {"uuid": "5502d664-87dc-4e88-928a-98ea7b6e2f1c", "name": "c876f41e-35b4-4931-9d0b-d9c056f9e7cf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6027984746974515, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12293402966163972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "83b5da43-aa46-4ca2-b714-e3e8d4d9aaa9", "name": "2d19e5a5-a6ec-41e1-82d1-d8affbe0489e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5502d664-87dc-4e88-928a-98ea7b6e2f1c"}}}]}, {"uuid": "f69095ba-372d-4810-8411-694971f43d18", "name": "load_p1rlv13628_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e47df44a-79f1-423b-a295-c9c354795895"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "83b5da43-aa46-4ca2-b714-e3e8d4d9aaa9"}}}}, {"uuid": "03010734-757c-40c6-8d5b-a9ba3e866412", "name": "c2fbd6ce-63a8-45aa-9508-6fc3cd17844f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6027984746974515, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12293402966163972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "28f34706-c5c5-47c0-8346-6aa590cb993d", "name": "f1053a09-9888-4e41-9153-fdb1d0b05c4b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "03010734-757c-40c6-8d5b-a9ba3e866412"}}}]}, {"uuid": "79aedce6-a8bc-4f93-b31b-189b72b22de8", "name": "load_p1rlv13628_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e47df44a-79f1-423b-a295-c9c354795895"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "28f34706-c5c5-47c0-8346-6aa590cb993d"}}}}, {"uuid": "00ece0df-1a03-4625-9c72-a0ca6a712f83", "name": "4e76d46b-b0e8-436f-9961-83e68ced5a03_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b240055e-61a7-4a40-8728-b15c9c4e3528", "name": "6954db8d-9915-4086-89b0-dd442cd5b3cb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "00ece0df-1a03-4625-9c72-a0ca6a712f83"}}}]}, {"uuid": "56bffc71-20a4-4d90-8fff-3853b9736046", "name": "load_p1rlv13629_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b4358536-b06f-486d-b336-3a8576b428d0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b240055e-61a7-4a40-8728-b15c9c4e3528"}}}}, {"uuid": "b5346d4f-4346-47c1-ad51-489a5fc3e057", "name": "ee48d810-87be-476c-b6e6-fde84b05eff7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4a16f94c-68e7-4d9b-a619-fb3c0c6948e1", "name": "a7574a04-fc39-4357-9ec9-540175bf69c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5346d4f-4346-47c1-ad51-489a5fc3e057"}}}]}, {"uuid": "d512e023-534b-4887-8712-d2b367fd903e", "name": "load_p1rlv13629_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b4358536-b06f-486d-b336-3a8576b428d0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4a16f94c-68e7-4d9b-a619-fb3c0c6948e1"}}}}, {"uuid": "db5ab1aa-2d9c-4125-94ab-3823975c45a3", "name": "44d7417b-8f31-4b33-a119-6accec609369_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.501244965400895, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7307193315393806, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d7b6bd43-b473-493b-bf4f-e32b4826ed05", "name": "cee0d6e8-87e3-4fd9-b102-fbbf8d850eb5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "db5ab1aa-2d9c-4125-94ab-3823975c45a3"}}}]}, {"uuid": "2af4f9b5-566b-464a-89b4-4f17c9947451", "name": "load_p1rlv13630_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f474e4ba-6300-4014-afe9-c245e08cf3c5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d7b6bd43-b473-493b-bf4f-e32b4826ed05"}}}}, {"uuid": "699807f1-fae9-44bc-88b0-f349cb4bed56", "name": "221e650d-7f9e-4569-b6d8-d9725b7f3b9d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.501244965400895, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7307193315393806, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "19f39d00-78bc-4894-a883-664fbe549f75", "name": "1bbe9954-28bc-42a3-9d62-ef25f2d9ce00", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "699807f1-fae9-44bc-88b0-f349cb4bed56"}}}]}, {"uuid": "e8373eda-07bd-4a9d-acc2-aa85eef3e840", "name": "load_p1rlv13630_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f474e4ba-6300-4014-afe9-c245e08cf3c5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "19f39d00-78bc-4894-a883-664fbe549f75"}}}}, {"uuid": "e3c35c21-d745-4909-889f-6bff9dea666a", "name": "8996a840-c56b-4244-a5bd-a936ab7e4f43_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7837050665512109, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.44874911637056014, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5ca7329c-2183-473b-95a9-77f2be94a3ca", "name": "0944f457-4c1a-46bc-b7c0-8ca6b1c791ce", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e3c35c21-d745-4909-889f-6bff9dea666a"}}}]}, {"uuid": "0a898f62-ea5c-418a-acc7-02c3c134dc37", "name": "load_p1rlv13631_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6015a810-79da-480f-b1a1-fd6a4abdba37"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5ca7329c-2183-473b-95a9-77f2be94a3ca"}}}}, {"uuid": "68c8d2e9-bf41-4d52-b183-24dae14b5724", "name": "248fdd00-1485-49b2-9fa5-142adc189657_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7837050665512109, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.44874911637056014, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b92698dc-2935-4f96-a813-b16d1e060ed2", "name": "1c437de2-b58b-4c30-af12-93c0d6925bcd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "68c8d2e9-bf41-4d52-b183-24dae14b5724"}}}]}, {"uuid": "91760696-f2be-4ed0-8a50-98d918418a84", "name": "load_p1rlv13631_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6015a810-79da-480f-b1a1-fd6a4abdba37"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b92698dc-2935-4f96-a813-b16d1e060ed2"}}}}, {"uuid": "625c002a-2b35-4e06-b117-f555d3def42e", "name": "05f7d4e7-22f5-4b84-ab66-ce7cc8d7b3fd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.008167500419157, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.871384812064858, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aae35308-2937-4f39-993b-ca2d5432f45b", "name": "0a7ea9ae-5600-43f7-aa3d-735141c55119", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "625c002a-2b35-4e06-b117-f555d3def42e"}}}]}, {"uuid": "d4468576-026b-47a1-ae83-e2a50b6701c7", "name": "load_p1rlv13632_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b712121-d0c2-488a-9224-bea72928796f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aae35308-2937-4f39-993b-ca2d5432f45b"}}}}, {"uuid": "85454153-f482-43f0-9863-54d33d19ad67", "name": "806f51fe-a83c-42ca-9771-481c667cb9fd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.008167500419157, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.871384812064858, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c5fb0cff-fe68-4ed9-b59f-4c1190ab0bf5", "name": "c5b13880-b54d-4f04-99cb-1632c874ae4a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "85454153-f482-43f0-9863-54d33d19ad67"}}}]}, {"uuid": "d2cb09f8-4845-4eb7-952d-96a7ea7bd35b", "name": "load_p1rlv13632_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b712121-d0c2-488a-9224-bea72928796f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c5fb0cff-fe68-4ed9-b59f-4c1190ab0bf5"}}}}, {"uuid": "4c650d9a-e789-4024-b747-a4f9b23a6fcb", "name": "c444ea98-6fdd-40da-bcdb-076334c4a3c8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4201171911594663, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7913664471178815, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7ddcbf16-7aee-400a-867b-1625d9b2aae7", "name": "e682a673-e790-4b62-937b-bbd1709020ea", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4c650d9a-e789-4024-b747-a4f9b23a6fcb"}}}]}, {"uuid": "a24f56d6-69d9-4acf-adf0-a7c175597c41", "name": "load_p1rlv13633_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b3fe33f-fdcf-42f5-be08-8da15a4d4958"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7ddcbf16-7aee-400a-867b-1625d9b2aae7"}}}}, {"uuid": "97c7df5d-7d20-4f19-a8df-ff4d27029248", "name": "919b3572-0eda-41a4-a30b-d2ebdca56740_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4201171911594663, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7913664471178815, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7d65b2fe-e861-403c-aacd-ff1a8c6f452e", "name": "2528e6e0-563d-4ad3-aef0-30576fc5cb62", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "97c7df5d-7d20-4f19-a8df-ff4d27029248"}}}]}, {"uuid": "c293303e-86dc-4b84-8db2-eedc97de8c50", "name": "load_p1rlv13633_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b3fe33f-fdcf-42f5-be08-8da15a4d4958"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7d65b2fe-e861-403c-aacd-ff1a8c6f452e"}}}}, {"uuid": "09ccac70-d664-460f-b367-a6828d226496", "name": "67a46fb3-067e-4411-9ca2-215ad98086df_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0491915565570302, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1506537762556939, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a9167dd0-eec4-4187-8d69-1b16829d38bb", "name": "0bcb7770-1b34-4ff2-a46b-7ab95042a64a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "09ccac70-d664-460f-b367-a6828d226496"}}}]}, {"uuid": "4174bb0a-452a-46f0-b4e9-42e67e6fb9f1", "name": "load_p1rlv13634_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "987b05d5-9bb9-434d-98b3-623ee5014870"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a9167dd0-eec4-4187-8d69-1b16829d38bb"}}}}, {"uuid": "a60ff0c5-8c9e-4430-bbe3-e61a9c4b32a2", "name": "a3ef54f3-b048-4cf2-b05c-35382e96d908_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0491915565570302, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1506537762556939, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bd28c65e-c687-47b6-afd7-6bd5a68ec166", "name": "461fcc9c-2fd7-4eab-9c4d-c95afcb50ac7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a60ff0c5-8c9e-4430-bbe3-e61a9c4b32a2"}}}]}, {"uuid": "fda346e7-2464-4bd6-8a0c-8e34f4705a79", "name": "load_p1rlv13634_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "987b05d5-9bb9-434d-98b3-623ee5014870"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bd28c65e-c687-47b6-afd7-6bd5a68ec166"}}}}, {"uuid": "03501c13-ff46-45d2-862c-55d026d69060", "name": "fa7fa910-1b72-44d2-88c9-2c5d4f2160ff_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.31125911334339, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6469035988597648, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "99b34702-aefb-4ecf-9662-efca449d746a", "name": "61b45131-846f-46d6-9521-ecd7655136f7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "03501c13-ff46-45d2-862c-55d026d69060"}}}]}, {"uuid": "2a209559-4d1c-4f42-9a45-244995b2999e", "name": "load_p1rlv13635_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc33013a-6a90-46a7-9127-f32288111c14"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "99b34702-aefb-4ecf-9662-efca449d746a"}}}}, {"uuid": "44aa3bec-ea60-44c4-844a-2e34f39d5b9d", "name": "d29dc4e2-aa32-48e4-831a-60e96c6c3418_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.31125911334339, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6469035988597648, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e2c7b5ec-90a9-45c2-bebe-68f2d9cf2fdf", "name": "ceecdb9d-06d8-43cb-8edc-f252113ff87f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "44aa3bec-ea60-44c4-844a-2e34f39d5b9d"}}}]}, {"uuid": "a846042f-a399-4b23-88b5-28a16125f77f", "name": "load_p1rlv13635_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc33013a-6a90-46a7-9127-f32288111c14"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e2c7b5ec-90a9-45c2-bebe-68f2d9cf2fdf"}}}}, {"uuid": "71f32ea8-d8a0-4783-b914-d623b778fdc7", "name": "e316d186-53a6-4f1c-9669-1116390b9f54_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d1ea5d58-0f18-4498-82c6-9d28a73a51a3", "name": "8ae641c4-13c7-49ad-937c-d462cbf99050", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "71f32ea8-d8a0-4783-b914-d623b778fdc7"}}}]}, {"uuid": "dde7312b-6aa6-4692-91ae-bd663ed25cb0", "name": "load_p1rlv13636_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4d3fe62-b327-4fc6-b2aa-795c9475019a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d1ea5d58-0f18-4498-82c6-9d28a73a51a3"}}}}, {"uuid": "50ebb994-5b3b-45b1-81a3-9101ce95a4ed", "name": "896c2f10-b80d-4849-bac7-9f63bbed8a43_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e70432b1-a134-47c3-b5c5-f7b43d821f3f", "name": "a3f8379e-dbf1-4014-ac38-e848ac421bca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "50ebb994-5b3b-45b1-81a3-9101ce95a4ed"}}}]}, {"uuid": "51241fc7-c76e-4bf9-a2ef-90652f4efae3", "name": "load_p1rlv13636_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4d3fe62-b327-4fc6-b2aa-795c9475019a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e70432b1-a134-47c3-b5c5-f7b43d821f3f"}}}}, {"uuid": "4c46cf04-de7e-4d34-bbfc-5cb180717b6e", "name": "16d6aa2b-a551-495d-af08-1e3622784797_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.942829069048031, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.025560880160820944, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "24d7765a-f07e-4e6b-8a5a-4df51bbf830a", "name": "2e3b5926-fa3e-41d3-bc84-1ba6532ae963", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4c46cf04-de7e-4d34-bbfc-5cb180717b6e"}}}]}, {"uuid": "3e2bd199-1a25-451c-a362-e3b28bbac774", "name": "load_p1rlv13637_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30c470ac-39d1-4379-9ae7-790d912bce2c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "24d7765a-f07e-4e6b-8a5a-4df51bbf830a"}}}}, {"uuid": "6a526513-421e-4dbf-9980-3c77433e854d", "name": "ed201a0a-e610-42cf-a003-a35c43a1cb2b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.942829069048031, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.025560880160820944, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b9cd2d9b-dd5e-4ea7-b10e-746c7a702745", "name": "69434e8b-8305-48f1-a6cb-4c5294aaae7f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6a526513-421e-4dbf-9980-3c77433e854d"}}}]}, {"uuid": "a00fc30c-06aa-41c0-a402-c6f017e5d5fc", "name": "load_p1rlv13637_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30c470ac-39d1-4379-9ae7-790d912bce2c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b9cd2d9b-dd5e-4ea7-b10e-746c7a702745"}}}}, {"uuid": "ad6f4b40-f5a4-47a2-964b-8ce502f3d7dc", "name": "11087ee2-87bd-4257-97dd-3f6eed4c5119_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9149869461814677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5767582022429075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "31e2e4b3-dc1e-466a-8d38-c2eac6c6dd63", "name": "9fcf32bf-adc6-4c44-b307-bd05599604cd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ad6f4b40-f5a4-47a2-964b-8ce502f3d7dc"}}}]}, {"uuid": "a15380e8-2648-4beb-8e30-e530c615396d", "name": "load_p1rlv13638_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db3908f7-94f5-43a7-a3de-1f6c9b72ebd4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "31e2e4b3-dc1e-466a-8d38-c2eac6c6dd63"}}}}, {"uuid": "c53ddde5-2039-402e-980c-16a0f3fdc516", "name": "f3182493-3ea8-4919-807c-2e5cf477f3b3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9149869461814677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5767582022429075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2d627562-5a99-4b97-810f-c0c324d6f7b2", "name": "4858ab75-c396-46a5-b5e9-eaf5f0a5acc5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c53ddde5-2039-402e-980c-16a0f3fdc516"}}}]}, {"uuid": "f767f99c-517e-4293-a22e-558482926470", "name": "load_p1rlv13638_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db3908f7-94f5-43a7-a3de-1f6c9b72ebd4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2d627562-5a99-4b97-810f-c0c324d6f7b2"}}}}, {"uuid": "2819f386-8f44-43b5-9d6c-678d19e3f8d7", "name": "3616b5fe-6980-4925-b3b2-eb27bbe1c497_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fd9ff23c-59b5-463a-b58b-27cdc50735ec", "name": "1c5e5eb7-33b3-4022-aaf7-45d672d8e2c0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2819f386-8f44-43b5-9d6c-678d19e3f8d7"}}}]}, {"uuid": "059d17b4-fe64-4805-bcd9-4e46f9e09235", "name": "load_p1rlv13639_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5484eab0-53a8-471c-92ec-29c11c08e740"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fd9ff23c-59b5-463a-b58b-27cdc50735ec"}}}}, {"uuid": "de1bfb30-3df8-4d09-8f71-222396ce7e69", "name": "0e34e63a-5733-4135-bba1-695543fae735_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f13d4010-6d55-4efe-8655-7521453e11e0", "name": "6210fd61-0848-43e8-9c2e-9c3bf700b9d0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "de1bfb30-3df8-4d09-8f71-222396ce7e69"}}}]}, {"uuid": "4f648b6f-b7e4-43fd-a91e-349c254189ca", "name": "load_p1rlv13639_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5484eab0-53a8-471c-92ec-29c11c08e740"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f13d4010-6d55-4efe-8655-7521453e11e0"}}}}, {"uuid": "ab18cebe-9955-405f-9911-fce8c9913a46", "name": "a471f35b-e72d-47c8-a43d-26e19b81faf7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "35d3008f-4e32-404e-a695-2aa7301c897b", "name": "2be52492-a9d7-4b9f-89e5-d7b666a6aff9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ab18cebe-9955-405f-9911-fce8c9913a46"}}}]}, {"uuid": "d9ba6877-fcb0-40d9-b3cc-e37733bf6458", "name": "load_p1rlv13640_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "653bdc0d-5b21-4640-861b-b88ddb5c651a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "35d3008f-4e32-404e-a695-2aa7301c897b"}}}}, {"uuid": "953924ef-3e84-4553-af18-876f4fe0fd5c", "name": "78c3d82f-a316-4d54-ab96-884224053acc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a3df4cb4-5997-4ca3-b6f5-33fe3f32a2bc", "name": "3b687e1f-5ad4-4334-8641-3a62e52c296d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "953924ef-3e84-4553-af18-876f4fe0fd5c"}}}]}, {"uuid": "98cf1c27-dbb5-4800-89c9-71335ef9faa2", "name": "load_p1rlv13640_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "653bdc0d-5b21-4640-861b-b88ddb5c651a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a3df4cb4-5997-4ca3-b6f5-33fe3f32a2bc"}}}}, {"uuid": "ff2bf355-ab80-4b01-998e-54880051bf9f", "name": "459eab03-c1ca-4265-8a6a-9806f03973e9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.725954562298933, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5866148963219024, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4adc22ee-af0f-46e4-b844-5de2777fadf9", "name": "f391628c-8d56-441e-bfda-3cc31ac49988", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ff2bf355-ab80-4b01-998e-54880051bf9f"}}}]}, {"uuid": "d30fa88e-eabd-48e1-b026-ecd2d7782dfc", "name": "load_p1rlv13641_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eb10938-4b73-406c-bed4-0bd01e0bc20d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4adc22ee-af0f-46e4-b844-5de2777fadf9"}}}}, {"uuid": "69cb7403-840f-440d-8a1a-b06c9aa92f0b", "name": "580fa1fd-d871-413b-a8f9-88bddf9d386a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.725954562298933, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5866148963219024, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82fc3122-1cc5-4744-9415-94b09dbd774f", "name": "8c1a17d5-8cde-4691-abb5-c4ad3ea0e1df", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "69cb7403-840f-440d-8a1a-b06c9aa92f0b"}}}]}, {"uuid": "ea414bd3-b37a-4371-a878-61328ce839fa", "name": "load_p1rlv13641_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eb10938-4b73-406c-bed4-0bd01e0bc20d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "82fc3122-1cc5-4744-9415-94b09dbd774f"}}}}, {"uuid": "d09f2a83-b5c9-4235-8679-a4570d4805f2", "name": "20d07da0-dae0-496c-9ca0-289a628db7bd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2219087879829873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3595087789107823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3831569f-5f73-48f2-a9ab-5a3616063410", "name": "3f700706-7d45-470d-8e42-ada404cb71e3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d09f2a83-b5c9-4235-8679-a4570d4805f2"}}}]}, {"uuid": "34ff9b20-48f4-434c-ad64-8773342da568", "name": "load_p1rlv13642_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "479d1486-ed05-44fa-8fab-64035623f267"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3831569f-5f73-48f2-a9ab-5a3616063410"}}}}, {"uuid": "ac8690af-35ef-4cf7-b728-5df66b0ec6ae", "name": "320e79cb-daa5-4360-97d5-7529918e9f19_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2219087879829873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3595087789107823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a4d6c511-9b88-47d5-9bf8-534ffb5d64a7", "name": "b03c670e-e129-426d-aa5d-d6c19f68019a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ac8690af-35ef-4cf7-b728-5df66b0ec6ae"}}}]}, {"uuid": "870c0741-671e-4fa5-8178-f061a1a30553", "name": "load_p1rlv13642_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "479d1486-ed05-44fa-8fab-64035623f267"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a4d6c511-9b88-47d5-9bf8-534ffb5d64a7"}}}}, {"uuid": "bd325d4d-1161-45e0-a72f-a63d6d594d11", "name": "0118f287-e659-44ea-b124-d4d4f7bd2f1f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0be1befb-4b3d-4ad7-a4af-35cac5f8452c", "name": "7f87bdbe-b5a6-4d42-b7eb-dac0ca68e3e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bd325d4d-1161-45e0-a72f-a63d6d594d11"}}}]}, {"uuid": "5ae8d23c-13f6-490b-bd31-a17c15dfad21", "name": "load_p1rlv13643_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20009de0-cbe7-4b4f-a046-425a6ae71925"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0be1befb-4b3d-4ad7-a4af-35cac5f8452c"}}}}, {"uuid": "c89ef2e0-f868-4dcd-bc19-b27e14951e25", "name": "f557316c-bda0-43e6-a08d-0bce1708c1af_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "393b1cad-6b55-4973-b28a-56692c2e4274", "name": "b9dca927-1456-4f14-a146-5f470c572560", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c89ef2e0-f868-4dcd-bc19-b27e14951e25"}}}]}, {"uuid": "0602d8b5-0a43-4a93-ba8a-e7eff78736a5", "name": "load_p1rlv13643_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20009de0-cbe7-4b4f-a046-425a6ae71925"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "393b1cad-6b55-4973-b28a-56692c2e4274"}}}}, {"uuid": "c1bbb515-b8c7-4c98-87e1-d29e17219acf", "name": "2489afdb-0ac5-4c87-b749-afc4d5c17807_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "45444b45-4777-4dcb-a5b6-a5318dd48642", "name": "95c301f7-5f36-46bb-a632-f91056dfd942", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c1bbb515-b8c7-4c98-87e1-d29e17219acf"}}}]}, {"uuid": "34afd116-cf35-4dee-8632-2c2db844aa7c", "name": "load_p1rlv13645_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1acad56e-b6d6-4fa7-a925-f242c1558eef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "45444b45-4777-4dcb-a5b6-a5318dd48642"}}}}, {"uuid": "729dec84-6190-48e8-8f28-1f1ac1ed1cae", "name": "5f2bf744-bd3e-4593-8c59-6ee59ce6ec97_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "545fd949-ca5f-4021-a9cb-70214da669b1", "name": "8e52d775-cd93-470f-a449-467dd1bd7da5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "729dec84-6190-48e8-8f28-1f1ac1ed1cae"}}}]}, {"uuid": "bab4d514-42f6-48f7-a8f0-3912a1e1a1c8", "name": "load_p1rlv13645_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1acad56e-b6d6-4fa7-a925-f242c1558eef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "545fd949-ca5f-4021-a9cb-70214da669b1"}}}}, {"uuid": "7de9fa63-d7d8-42be-8950-590bc369ae2a", "name": "1d3651b2-1ade-49fb-ab57-a9b07ad20ade_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4519136613739017, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7054970531635038, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c531f4fd-237f-4a4e-b8df-650e5c906732", "name": "956fe972-4e01-481c-84e7-1b6cbfeb7f20", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7de9fa63-d7d8-42be-8950-590bc369ae2a"}}}]}, {"uuid": "5599b81a-cb04-4ba8-95c5-f2ce0818c160", "name": "load_p1rlv13646_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fe0466e-cce5-4c6c-b13f-cedd349b6944"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c531f4fd-237f-4a4e-b8df-650e5c906732"}}}}, {"uuid": "d90b4bd1-901f-4ed8-b6c2-18f91fb1fbe0", "name": "288608e5-0375-438e-9815-90b527a03a3c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4519136613739017, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7054970531635038, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "615b821c-a77c-4577-9683-6b35a7e599b8", "name": "27907f11-b1a1-49ea-ac02-b474b0ee1296", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d90b4bd1-901f-4ed8-b6c2-18f91fb1fbe0"}}}]}, {"uuid": "49d1c147-c2e7-4c73-8f8c-c68335fae76f", "name": "load_p1rlv13646_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fe0466e-cce5-4c6c-b13f-cedd349b6944"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "615b821c-a77c-4577-9683-6b35a7e599b8"}}}}, {"uuid": "8ded91d9-819a-41a7-9317-5644c2b21466", "name": "ea7f762c-ce75-4d60-ace7-be83382b67ef_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7813411640480736, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4182052484168413, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "badfcc26-ec8f-4d69-827c-6970fb6fffba", "name": "2a06c444-3e0e-4bed-901f-2fcc499def0b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ded91d9-819a-41a7-9317-5644c2b21466"}}}]}, {"uuid": "a8732407-5084-4d7d-bc08-770676d828cd", "name": "load_p1rlv13647_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8753d37-07f1-45c6-a483-43cbfb6bf107"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "badfcc26-ec8f-4d69-827c-6970fb6fffba"}}}}, {"uuid": "b5e8a61b-47e3-4497-a372-da74225c037d", "name": "698ba49f-a12a-4a1c-a60e-3a4224a3fdf4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7813411640480736, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4182052484168413, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9905e932-f6db-4c5a-9953-3ae517967290", "name": "a8e4cb2a-552f-477b-990a-7d4864067f6b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5e8a61b-47e3-4497-a372-da74225c037d"}}}]}, {"uuid": "929e7d4b-7ca0-420b-a59f-8131acee3c6e", "name": "load_p1rlv13647_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8753d37-07f1-45c6-a483-43cbfb6bf107"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9905e932-f6db-4c5a-9953-3ae517967290"}}}}, {"uuid": "d9f54d7b-c79c-4e40-98df-ea703f5ac70d", "name": "e5c3a58c-b408-4539-89ca-bf1cf35ce61e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1343287185333217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10429894918818222, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "090bd7d6-3f1f-4e27-b141-78a2939dc01f", "name": "01cc5f96-812a-4b61-b1ee-ae944d1e9e2f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d9f54d7b-c79c-4e40-98df-ea703f5ac70d"}}}]}, {"uuid": "655fa1cb-f8f2-445b-8380-e4606ad75131", "name": "load_p1rlv13648_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62a29ac5-7227-43b2-b602-b1189cc93839"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "090bd7d6-3f1f-4e27-b141-78a2939dc01f"}}}}, {"uuid": "8a0039a2-6d46-4a15-89fd-0e48ddfa2026", "name": "13fc6f7a-f857-4fb9-9f1c-3fa2e404205f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1343287185333217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10429894918818222, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "edd294c3-09a4-4f8a-843d-59f0732f18cd", "name": "2de0392e-0063-46cd-873d-8218831e2e65", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a0039a2-6d46-4a15-89fd-0e48ddfa2026"}}}]}, {"uuid": "7f04e3b5-99a3-417b-9ea6-f2daab8d6fe8", "name": "load_p1rlv13648_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62a29ac5-7227-43b2-b602-b1189cc93839"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "edd294c3-09a4-4f8a-843d-59f0732f18cd"}}}}, {"uuid": "c0691bdd-89f2-488e-914c-503562a2c816", "name": "d5241df9-210a-4632-ba1f-31f5903cefa6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "905b259c-5f98-4478-a1d2-fcbedf1ada7e", "name": "03f14100-0af1-4c78-872a-9c54c3c9bdad", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c0691bdd-89f2-488e-914c-503562a2c816"}}}]}, {"uuid": "274e8dac-f955-4b5d-877d-34b969f045d4", "name": "load_p1rlv13649_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43867e2f-79ee-4cec-bed3-0cad0727118c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "905b259c-5f98-4478-a1d2-fcbedf1ada7e"}}}}, {"uuid": "adf27202-e69a-467a-9e93-2b422c27b8f5", "name": "b86a783e-92c5-4b8b-8f04-8de9193fa62b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b7b902de-dea3-4126-ab0b-8d5a36d63c29", "name": "03e22a3c-06dd-436a-a577-32b9e21ca18c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "adf27202-e69a-467a-9e93-2b422c27b8f5"}}}]}, {"uuid": "06d40c7c-d7d4-443a-b8aa-91d579b4708f", "name": "load_p1rlv13649_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43867e2f-79ee-4cec-bed3-0cad0727118c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b7b902de-dea3-4126-ab0b-8d5a36d63c29"}}}}, {"uuid": "d7d5af8b-daf2-4e4e-9b0d-ed795ed513cc", "name": "658f477d-eaba-4943-a7ee-2a81555af2a2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2570744264864886, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.02246974709606756, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bc03626c-630c-437c-81dd-3315b3978341", "name": "48a360e8-d80c-47b5-b6ba-5ff066efe523", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d7d5af8b-daf2-4e4e-9b0d-ed795ed513cc"}}}]}, {"uuid": "e539658e-9b51-4f32-8034-dfd8818aab1c", "name": "load_p1rlv13650_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fa2041e-34c4-4f1f-a329-74969c3da75f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bc03626c-630c-437c-81dd-3315b3978341"}}}}, {"uuid": "f6a3c7a8-3d24-4f7b-b91c-cb9c3f0b4f3f", "name": "e9d2125e-d841-4d9e-9531-0deabe5a9e78_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2570744264864886, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.02246974709606756, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d0336c96-d254-48cb-a8ab-5ca8ee4e509a", "name": "f759eb0e-e52e-4935-8183-af965777f183", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f6a3c7a8-3d24-4f7b-b91c-cb9c3f0b4f3f"}}}]}, {"uuid": "21214c31-8a2f-45c9-91dd-98abd124759a", "name": "load_p1rlv13650_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fa2041e-34c4-4f1f-a329-74969c3da75f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d0336c96-d254-48cb-a8ab-5ca8ee4e509a"}}}}, {"uuid": "dced574f-ef99-4a2b-ad7a-a26535c32b88", "name": "bed9e268-e4a4-4f24-85be-f266452ffd30_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d0c5d89c-bf53-4014-9e6c-fa9efe4580a4", "name": "4ef69988-cd3c-42a1-a5d2-6cddc8fe53ce", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dced574f-ef99-4a2b-ad7a-a26535c32b88"}}}]}, {"uuid": "4408d259-bb84-44ec-b02f-067428660b1d", "name": "load_p1rlv13651_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c808261e-a49e-4954-bdc4-a8b63d0ee25b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d0c5d89c-bf53-4014-9e6c-fa9efe4580a4"}}}}, {"uuid": "d1fc4eeb-9cc6-4172-b6d4-7289ca5ec624", "name": "a178b7f7-d214-4e92-b211-dec0140ceedb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4aa2831b-6bb2-4cc4-b21f-c46883712692", "name": "e7ae22a7-1090-4452-b54d-fd3f31d49079", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d1fc4eeb-9cc6-4172-b6d4-7289ca5ec624"}}}]}, {"uuid": "373dc048-2ea4-417c-8487-61c88a796053", "name": "load_p1rlv13651_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c808261e-a49e-4954-bdc4-a8b63d0ee25b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4aa2831b-6bb2-4cc4-b21f-c46883712692"}}}}, {"uuid": "69dfdb76-e6ee-4abd-9f38-d45756695404", "name": "36741a16-86b3-44a9-a284-dc5f6ede04b7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9eb220af-0b1b-474d-8a61-2dc6f753fbc0", "name": "ad9f0501-1f15-475c-ada7-35b8c17f18d2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "69dfdb76-e6ee-4abd-9f38-d45756695404"}}}]}, {"uuid": "e3181116-934c-4c25-bd6e-f1e06020124d", "name": "load_p1rlv13652_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3310c14a-d1ee-4d0c-8428-d002703c61d5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9eb220af-0b1b-474d-8a61-2dc6f753fbc0"}}}}, {"uuid": "b2c54594-b1f9-4654-a1b7-420fb0dc3ecf", "name": "62d8c279-f33b-48e5-a06f-2b23ab118224_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2f905575-f631-4ca9-b41d-5ee46496fbfb", "name": "a4c287e9-487e-469e-90ae-cc3f25dee8a0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b2c54594-b1f9-4654-a1b7-420fb0dc3ecf"}}}]}, {"uuid": "e4a891ed-1399-4dae-bb21-1c5fd0c3f2ff", "name": "load_p1rlv13652_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3310c14a-d1ee-4d0c-8428-d002703c61d5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2f905575-f631-4ca9-b41d-5ee46496fbfb"}}}}, {"uuid": "e8bc5267-78dd-4572-b99c-9781edf1a03b", "name": "79722852-e477-4e90-bf4d-de348b8f8c31_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "304e5081-f254-4df0-aae5-f92b694735e8", "name": "9c23987e-3fbd-447d-900b-dd0b801ca8c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e8bc5267-78dd-4572-b99c-9781edf1a03b"}}}]}, {"uuid": "604756e6-8f23-42e6-8335-c7165a48f07b", "name": "load_p1rlv13653_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c61a243-7736-46a0-a950-7cc811381158"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "304e5081-f254-4df0-aae5-f92b694735e8"}}}}, {"uuid": "95b6cfff-b677-446f-8b23-227e177a695b", "name": "48a93325-7a1d-4671-8fae-2adbe2094009_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "70026483-7529-4ffe-8f3b-b6cae4805814", "name": "4e95a876-9d1b-41a0-865f-9347f0ce019a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "95b6cfff-b677-446f-8b23-227e177a695b"}}}]}, {"uuid": "cacbe185-64b6-4e12-b4d8-3d92da57d657", "name": "load_p1rlv13653_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c61a243-7736-46a0-a950-7cc811381158"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "70026483-7529-4ffe-8f3b-b6cae4805814"}}}}, {"uuid": "4215e0af-da77-4d2e-a0be-8d321ac4f6d0", "name": "7ff3ae74-0d5b-45c6-b5dd-9a103a883b8c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82b2e12e-7a54-461c-9aeb-a222f058ec8e", "name": "8a57889c-3821-45cc-9438-a0a84fa702c4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4215e0af-da77-4d2e-a0be-8d321ac4f6d0"}}}]}, {"uuid": "b972ad59-d151-468c-bbd8-0fe62c96767f", "name": "load_p1rlv13654_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7be734c-88e2-42c1-8061-f4632bd05759"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "82b2e12e-7a54-461c-9aeb-a222f058ec8e"}}}}, {"uuid": "e3fd7e6b-3be9-468b-bb42-7a08e9ec8e27", "name": "e67ffab9-dfac-41eb-bbf4-9ebff2f3e456_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1fc8c2fb-8515-4441-b436-ab518d71744e", "name": "cb0ab9b6-7b48-4770-9f04-f90333d35c5e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e3fd7e6b-3be9-468b-bb42-7a08e9ec8e27"}}}]}, {"uuid": "d10b8868-8b0b-47ff-be2a-454a09676e6b", "name": "load_p1rlv13654_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7be734c-88e2-42c1-8061-f4632bd05759"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1fc8c2fb-8515-4441-b436-ab518d71744e"}}}}, {"uuid": "56b5f355-041e-4dba-ba09-03809c3c5b2e", "name": "a40afe02-c157-4c26-9cf8-bd7fa2dd4dd2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6323867069620042, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.40255171211713736, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "baeaae15-0168-4ba2-837d-7809208f82e6", "name": "7dd8ae54-e6f6-436b-a88f-4802f0aee048", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "56b5f355-041e-4dba-ba09-03809c3c5b2e"}}}]}, {"uuid": "349940a9-30e6-4bcf-b4ea-7dc077419d78", "name": "load_p1rlv13656_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8c0a04e-6e22-4da5-9907-7ae8097deb10"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "baeaae15-0168-4ba2-837d-7809208f82e6"}}}}, {"uuid": "b952e3d4-9a7c-40a3-9164-9d0dd955044a", "name": "8dc31abf-deda-4dfa-b7bf-e8f0ac40e338_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6323867069620042, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.40255171211713736, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c0c3b87a-70c4-4b94-b70b-f055b01e00b8", "name": "7196cb5a-f515-4eb5-aa7d-88db8da976a5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b952e3d4-9a7c-40a3-9164-9d0dd955044a"}}}]}, {"uuid": "37c16384-4d78-48e7-881c-0d1f7e0836e3", "name": "load_p1rlv13656_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8c0a04e-6e22-4da5-9907-7ae8097deb10"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c0c3b87a-70c4-4b94-b70b-f055b01e00b8"}}}}, {"uuid": "1f18b628-04c5-4373-aba7-c517e5f25cfd", "name": "286482c8-f090-4cae-8a2e-a73d7db99feb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3136780250521567, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6274781256964336, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "81b85d52-3498-43a8-936c-0438a3a1e77a", "name": "624e03d2-a2a3-40e9-a4ce-1cb0baf735ec", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1f18b628-04c5-4373-aba7-c517e5f25cfd"}}}]}, {"uuid": "65dd228a-3e18-4462-8f6e-0b8ef359f3c7", "name": "load_p1rlv13659_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "122e0772-7de6-4117-b1d3-caafbbbc8e22"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "81b85d52-3498-43a8-936c-0438a3a1e77a"}}}}, {"uuid": "4a0d6619-6653-4170-94df-7f94241e7756", "name": "e731fb7a-2aac-4405-9829-9a124878e978_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3136780250521567, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6274781256964336, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a9b8aef4-770c-4605-91fb-cf5f65bac8ad", "name": "cc3f61f1-61e1-4095-be99-dd251406fe77", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4a0d6619-6653-4170-94df-7f94241e7756"}}}]}, {"uuid": "869b76e9-b831-42f3-8bfe-4034fcee94b6", "name": "load_p1rlv13659_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "122e0772-7de6-4117-b1d3-caafbbbc8e22"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a9b8aef4-770c-4605-91fb-cf5f65bac8ad"}}}}, {"uuid": "1e3a44b0-0311-4a0a-920f-31d3cb8071ea", "name": "a6035deb-21e9-40d2-b1e3-5a81cf2ca1fa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.451252731053624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.713074208581691, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a7a72458-f0a7-4e0f-bab5-35516828e6fa", "name": "05101890-58cb-4a6a-998d-7a80d1a38c47", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1e3a44b0-0311-4a0a-920f-31d3cb8071ea"}}}]}, {"uuid": "aa4f58db-b7d9-429e-a7b8-d50bf374567d", "name": "load_p1rlv13660_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3d6fd13-2f04-4f23-97a3-cdf99159174c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a7a72458-f0a7-4e0f-bab5-35516828e6fa"}}}}, {"uuid": "f7ac0d69-63e9-40a3-81c8-4d9210203563", "name": "68272a3f-b73a-49ac-b04a-74e14740c79c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.451252731053624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.713074208581691, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b2a24286-1b0d-43bd-afe4-9a13c48cf1dd", "name": "9722d5dd-1118-4ef5-be44-6db735db2110", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f7ac0d69-63e9-40a3-81c8-4d9210203563"}}}]}, {"uuid": "d8533016-a154-475b-ae9b-fe6c0e150256", "name": "load_p1rlv13660_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3d6fd13-2f04-4f23-97a3-cdf99159174c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b2a24286-1b0d-43bd-afe4-9a13c48cf1dd"}}}}, {"uuid": "49b8597a-96da-4788-9afb-f420e2d395d7", "name": "f0537617-b121-403f-ba70-6877fc568219_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "16d19764-29c0-4188-95fd-b5ccbb16d11f", "name": "2e81f190-f3c8-4018-9677-fd85b083ba16", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "49b8597a-96da-4788-9afb-f420e2d395d7"}}}]}, {"uuid": "fd271e1a-15aa-4d19-ac28-1921b1f5a1a5", "name": "load_p1rlv13661_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ef8e6ec-86d3-429c-89b4-6c7260701e70"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "16d19764-29c0-4188-95fd-b5ccbb16d11f"}}}}, {"uuid": "6ee4c0dc-6e94-42a4-883c-00fe63e6c34a", "name": "758a5607-2d31-45ef-b75f-52aed25d24fd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ff2dc44d-7d99-4780-9681-ce8f29bd282b", "name": "0eefbf1a-f69c-4f42-a699-ea939db89f8c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6ee4c0dc-6e94-42a4-883c-00fe63e6c34a"}}}]}, {"uuid": "a56c3c6c-7ab4-4461-850f-b48a81dc968d", "name": "load_p1rlv13661_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ef8e6ec-86d3-429c-89b4-6c7260701e70"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ff2dc44d-7d99-4780-9681-ce8f29bd282b"}}}}, {"uuid": "f8133e03-31d5-42d7-bd88-4cc213bcb5b7", "name": "0ba1e3ee-b48a-4b3d-b892-f58040d5479b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2219087879829873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3595087789107823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "df9dad07-8131-40cb-9a8f-064c58479727", "name": "2f22329d-168a-44bd-9637-93fb93b0ccc0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8133e03-31d5-42d7-bd88-4cc213bcb5b7"}}}]}, {"uuid": "14568d59-4779-4b82-bd4c-7d6f84a4677a", "name": "load_p1rlv13662_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e55b944-ffad-47bf-8348-799afa4c7a1d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "df9dad07-8131-40cb-9a8f-064c58479727"}}}}, {"uuid": "50e89d97-6a00-4d85-8890-0efccc86d1d6", "name": "2fad6a38-3c6a-498d-9e60-183787ca00b4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2219087879829873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3595087789107823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4980cbef-343f-4f1c-8a0c-b1bb4d46f7a8", "name": "888f46ed-ff0c-4187-a262-a4883c066470", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "50e89d97-6a00-4d85-8890-0efccc86d1d6"}}}]}, {"uuid": "99b31d76-0371-49fb-aee3-ea5f640aca86", "name": "load_p1rlv13662_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e55b944-ffad-47bf-8348-799afa4c7a1d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4980cbef-343f-4f1c-8a0c-b1bb4d46f7a8"}}}}, {"uuid": "35f09a5f-e76d-4143-a0a1-6b6528905ecf", "name": "e92bb2ae-6b5b-4423-90a4-55f00d52ee1d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4037437915385973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5086059213404144, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c6cf5817-c9e9-42bd-8fa8-1d2f0deb9b7a", "name": "e9e871ed-52e9-4ea3-a1e7-ee2dce5ddc1d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "35f09a5f-e76d-4143-a0a1-6b6528905ecf"}}}]}, {"uuid": "69ddfb6d-3d94-4dab-81e2-68581c898457", "name": "load_p1rlv13663_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54887ca7-ae23-42d0-a715-aed8baa38ade"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c6cf5817-c9e9-42bd-8fa8-1d2f0deb9b7a"}}}}, {"uuid": "553e3b41-b83a-479c-9900-962640ead61c", "name": "8fdeee45-7875-4773-939f-6c2eededbcea_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4037437915385973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5086059213404144, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "00a29a22-4c22-47bf-bd3a-c7811900b5c7", "name": "15aea7ce-4acb-45f9-9a2d-6cec7461ff24", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "553e3b41-b83a-479c-9900-962640ead61c"}}}]}, {"uuid": "de470297-775d-41a9-a47c-c5d09e70a32c", "name": "load_p1rlv13663_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54887ca7-ae23-42d0-a715-aed8baa38ade"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "00a29a22-4c22-47bf-bd3a-c7811900b5c7"}}}}, {"uuid": "b93948c1-dbe7-4ace-bdfd-789dc22a235e", "name": "424fbac6-cc35-412a-8694-f8c7ff2dbe5d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.171921265639173, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.29621618517422543, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "370843e6-cc97-4f14-bd5d-71ce37f2fd6d", "name": "da0ddf58-b766-4b91-93f4-ce4eac28b240", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b93948c1-dbe7-4ace-bdfd-789dc22a235e"}}}]}, {"uuid": "f2fcf549-f097-41f8-8ff2-c5cee47e5668", "name": "load_p1rlv13664_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70cf02cc-8f1b-48ab-b9e6-50c3e58ad9ae"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "370843e6-cc97-4f14-bd5d-71ce37f2fd6d"}}}}, {"uuid": "3116d69b-7117-4fd8-b4e9-76d7811456b4", "name": "7fbb6319-51f4-447f-b58e-f3c627cbc17b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.171921265639173, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.29621618517422543, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a81205d-cea1-4b5b-bf2b-ef3f9c494db7", "name": "1681ffde-b20c-43e2-be25-1228adb048cb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3116d69b-7117-4fd8-b4e9-76d7811456b4"}}}]}, {"uuid": "e5513cae-ff8c-4f6a-82a0-f7fe9d4d4983", "name": "load_p1rlv13664_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70cf02cc-8f1b-48ab-b9e6-50c3e58ad9ae"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a81205d-cea1-4b5b-bf2b-ef3f9c494db7"}}}}, {"uuid": "561dd82a-ae45-4f18-b612-97489aafacb7", "name": "0510710f-c864-4bc0-a449-3dd4188e126d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6009666033769583, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.30487867399122176, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "298f4a0a-6d5a-4036-9050-3b41e1d5f3a5", "name": "fa52f6fb-68d6-49a3-a8ed-829fba2b4bfa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "561dd82a-ae45-4f18-b612-97489aafacb7"}}}]}, {"uuid": "f19c4f4e-5559-4646-b2ae-a189dca4a78e", "name": "load_p1rlv13666_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5868c24b-2a58-459b-8650-a6072241aca8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "298f4a0a-6d5a-4036-9050-3b41e1d5f3a5"}}}}, {"uuid": "2d6621c8-2e92-45df-b7e3-67b7c537e629", "name": "68f1ea3e-f95b-4303-b2a6-98908bdf41d3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6009666033769583, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.30487867399122176, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ce9c0f2e-efd6-4773-b074-1efb58ce18f8", "name": "2d068a03-d5cf-44f3-8e39-40e41e6e57b1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2d6621c8-2e92-45df-b7e3-67b7c537e629"}}}]}, {"uuid": "65c1c2bb-7594-4118-8ba2-bbd216d7ea0f", "name": "load_p1rlv13666_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5868c24b-2a58-459b-8650-a6072241aca8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ce9c0f2e-efd6-4773-b074-1efb58ce18f8"}}}}, {"uuid": "06e41b5d-b214-4e44-8975-b0649d93fe60", "name": "59d31c8d-fdd0-46b2-9502-0fd377ff435a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10b6ca4c-b522-4c46-a7f0-743befb358a6", "name": "a202078d-d353-405c-8692-4abd9581de19", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "06e41b5d-b214-4e44-8975-b0649d93fe60"}}}]}, {"uuid": "4f0a7fbd-d525-4b67-b610-ecc4dbc20dee", "name": "load_p1rlv13667_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d6cdd514-204d-4a86-b0f3-a9bc4990a2aa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10b6ca4c-b522-4c46-a7f0-743befb358a6"}}}}, {"uuid": "ac4210ab-7389-4005-a2ef-073ae6873999", "name": "d8bea9da-89f9-4072-860e-9420f53c46e6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e534cee0-6684-4f52-bc0e-6cd84309dc93", "name": "dea8c815-395b-4c6a-899d-054e1a145d92", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ac4210ab-7389-4005-a2ef-073ae6873999"}}}]}, {"uuid": "858e4943-fb33-4590-9ee4-155d15a843e1", "name": "load_p1rlv13667_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d6cdd514-204d-4a86-b0f3-a9bc4990a2aa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e534cee0-6684-4f52-bc0e-6cd84309dc93"}}}}, {"uuid": "c08997c7-db55-40c4-bf71-998de5dc6a71", "name": "9355b24d-6e65-4b80-8e20-c4cf4483930b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.243385388928283, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18185664736822973, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "843280bd-9358-4b99-85d7-c0dd09bf6f7b", "name": "8c70ecf7-eaa5-4b44-adf6-b23c782fbcc0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c08997c7-db55-40c4-bf71-998de5dc6a71"}}}]}, {"uuid": "823f5fdd-d975-4ec1-a4c5-7eb9e943a700", "name": "load_p1rlv13669_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "607d3b54-2cea-476b-afe2-ea40c6c02ddc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "843280bd-9358-4b99-85d7-c0dd09bf6f7b"}}}}, {"uuid": "669b92ac-4005-42e9-989d-1da0b09a1c0d", "name": "c9ff654e-5d95-48b2-9c5d-aaa5f5920f16_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.243385388928283, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18185664736822973, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "13843380-871f-4a44-97d5-19edb10e8cd1", "name": "7857066d-2d99-4610-9671-18cdf4e6d73f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "669b92ac-4005-42e9-989d-1da0b09a1c0d"}}}]}, {"uuid": "42d869a0-9001-4c85-96d5-1bd32d6d9a19", "name": "load_p1rlv13669_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "607d3b54-2cea-476b-afe2-ea40c6c02ddc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "13843380-871f-4a44-97d5-19edb10e8cd1"}}}}, {"uuid": "c824570f-41c3-4658-98ee-b5d38899b6fb", "name": "5420d868-605b-4836-9448-e01ad2898845_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ad43811a-0dce-48b2-8dad-193d26dc5c7e", "name": "94d0f2f7-b64e-4f42-9c92-9cbce5357977", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c824570f-41c3-4658-98ee-b5d38899b6fb"}}}]}, {"uuid": "4eec0c4e-00d7-4bec-949d-5a1648f8cc2e", "name": "load_p1rlv13670_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce53d307-fc73-487a-8f6a-3a0e0787bf79"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ad43811a-0dce-48b2-8dad-193d26dc5c7e"}}}}, {"uuid": "cd9f93af-ec5b-4d27-9244-d0d906a65dca", "name": "ddd68ff7-775d-4432-b32b-67e2f60fa9fa_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fadec189-327c-4c49-9a41-e9f44f088a90", "name": "f30ed151-47fc-40fe-9c37-0b39891ad867", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cd9f93af-ec5b-4d27-9244-d0d906a65dca"}}}]}, {"uuid": "3c0757fe-078a-4f99-9037-7bf31dd78c2c", "name": "load_p1rlv13670_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce53d307-fc73-487a-8f6a-3a0e0787bf79"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fadec189-327c-4c49-9a41-e9f44f088a90"}}}}, {"uuid": "cce1d914-3897-415d-94c9-0bda66e7584b", "name": "a9637591-c10b-4105-8b34-4ea3820ade8e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9288466752414104, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5041700498617779, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "83e11efa-0cb8-4d77-a6fb-48c4441831cd", "name": "c980a120-d7d0-4495-9d41-52fcb27a478c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cce1d914-3897-415d-94c9-0bda66e7584b"}}}]}, {"uuid": "a20a8092-569d-43be-b17c-299bca2d34fb", "name": "load_p1rlv13671_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2f95b8b-190c-4df2-9dd2-daee5efde34b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "83e11efa-0cb8-4d77-a6fb-48c4441831cd"}}}}, {"uuid": "98e84956-76ab-4a79-ac91-0c753fc10395", "name": "4ecc3f34-13d4-49e2-9636-c3822922023a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9288466752414104, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5041700498617779, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "406dfc6a-2106-4f9a-bb1a-e36b1874ac5c", "name": "865d5e0b-db3c-441b-a3ec-9d306b528262", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "98e84956-76ab-4a79-ac91-0c753fc10395"}}}]}, {"uuid": "05cffae3-c68a-4ca1-9c2c-6d472dcac594", "name": "load_p1rlv13671_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2f95b8b-190c-4df2-9dd2-daee5efde34b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "406dfc6a-2106-4f9a-bb1a-e36b1874ac5c"}}}}, {"uuid": "eac080d0-ce9f-4a11-9e89-064e9652e90a", "name": "5c0125ca-ef8b-4355-ad66-e1e6c40caf68_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c6d2010-b22f-4f29-a013-2e6988795d7b", "name": "80d25aa9-7fde-4ccf-a1b1-35cd5fab65b4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eac080d0-ce9f-4a11-9e89-064e9652e90a"}}}]}, {"uuid": "8d4e629f-b47d-4680-be3c-57609d082098", "name": "load_p1rlv13672_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32bec8ad-b312-4502-a2a1-6a4c9b2dd87a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c6d2010-b22f-4f29-a013-2e6988795d7b"}}}}, {"uuid": "029cbe02-f40e-47e9-8a6a-d7387d5abab2", "name": "50f4da33-f660-4b22-bf6b-fe34737078fb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3b0fd302-f287-459a-ae23-7476c857531f", "name": "a26442c2-5ac1-47c4-a2b3-b4ab086af933", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "029cbe02-f40e-47e9-8a6a-d7387d5abab2"}}}]}, {"uuid": "8a1bf579-c074-4fed-986e-85b6783e25cc", "name": "load_p1rlv13672_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32bec8ad-b312-4502-a2a1-6a4c9b2dd87a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3b0fd302-f287-459a-ae23-7476c857531f"}}}}, {"uuid": "693b4667-daea-4e40-bfff-dd1959206f97", "name": "fc721459-308e-4879-bc34-b613e7f7c85c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7935386970404408, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "55f52881-bd1e-4e64-92b8-eebaa9951c1d", "name": "d510a2f4-a1e2-4e21-af2f-a876e4b9c568", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "693b4667-daea-4e40-bfff-dd1959206f97"}}}]}, {"uuid": "e3e6f22c-25bc-4daa-ba19-48a3f4bf03d1", "name": "load_p1rlv13673_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9467d2d3-ad80-4bc7-aa9f-cd6e76494552"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "55f52881-bd1e-4e64-92b8-eebaa9951c1d"}}}}, {"uuid": "8fca9d32-1a27-4937-ab5d-7af131c409a2", "name": "0537dda4-bdba-4b71-b8b6-1d9426ed5389_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7935386970404408, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d8163229-e0c4-41cf-a995-7a616b434812", "name": "2c77a221-82e8-4961-ae91-366e528cbae6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8fca9d32-1a27-4937-ab5d-7af131c409a2"}}}]}, {"uuid": "189e9cc4-5dee-4a05-b818-18d261acbaf3", "name": "load_p1rlv13673_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9467d2d3-ad80-4bc7-aa9f-cd6e76494552"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d8163229-e0c4-41cf-a995-7a616b434812"}}}}, {"uuid": "cdcbb941-fd4c-47f7-99d4-b5833522ee8e", "name": "fcd8614f-b0c9-4179-a0bd-6de5a6d6295a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3711169311548215, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.698133467399761, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a39d1a35-4104-4eed-bd3a-065a7b917b55", "name": "ec8fff74-3bfd-4245-a89b-a6c8db3c0025", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cdcbb941-fd4c-47f7-99d4-b5833522ee8e"}}}]}, {"uuid": "a82d7413-7003-40aa-a574-389c577ecef9", "name": "load_p1rlv13675_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c532e298-bdd5-416e-8ebe-a082489ffee6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a39d1a35-4104-4eed-bd3a-065a7b917b55"}}}}, {"uuid": "f8c09000-4b28-45b6-a38a-de39aa272539", "name": "3bd3720d-ffed-4317-a656-460de94fe06e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3711169311548215, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.698133467399761, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8c8addae-8650-47cd-9563-df844c7de159", "name": "f50d2292-b086-4db1-8466-6afb06457711", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8c09000-4b28-45b6-a38a-de39aa272539"}}}]}, {"uuid": "60ee37ce-bbe8-486f-b6e2-c9b26c754bd1", "name": "load_p1rlv13675_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c532e298-bdd5-416e-8ebe-a082489ffee6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8c8addae-8650-47cd-9563-df844c7de159"}}}}, {"uuid": "0fff1cf9-f15e-4586-b11a-72f58c6f6003", "name": "a98e48cc-d122-4e98-a9c0-1fadf8c53d63_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3cc3a673-8856-4f3b-9c8f-f7daaa17fb65", "name": "cb431138-581d-4918-b0c8-cae906037191", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0fff1cf9-f15e-4586-b11a-72f58c6f6003"}}}]}, {"uuid": "b627c3b4-2b03-4e8f-a8be-61431fb5fd12", "name": "load_p1rlv13676_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8df1a69e-5b18-4eef-ab60-543a97257297"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3cc3a673-8856-4f3b-9c8f-f7daaa17fb65"}}}}, {"uuid": "6a22ceca-21eb-466d-9d9e-c24cc239af5d", "name": "742fed2a-5e6e-4add-9b6b-9ac27249fd3a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a0765586-2c2e-40b8-b1cf-e8c980220f17", "name": "7629d3d9-c942-4811-958e-2bd2ac62601e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6a22ceca-21eb-466d-9d9e-c24cc239af5d"}}}]}, {"uuid": "131c54ad-6996-45ed-96ad-bca519031e12", "name": "load_p1rlv13676_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8df1a69e-5b18-4eef-ab60-543a97257297"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a0765586-2c2e-40b8-b1cf-e8c980220f17"}}}}, {"uuid": "2159daa7-94bc-4a90-b7e3-9380fe01ef2f", "name": "95d4f202-1a21-460c-bb0e-64573f95dc6f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 12.611907582113087, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.885290064059574, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "526c56c3-9921-4fa4-a847-f1aaf7e2bf36", "name": "f0684b75-8c89-4aee-b462-56154d3d838e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2159daa7-94bc-4a90-b7e3-9380fe01ef2f"}}}]}, {"uuid": "38ef36d4-caaa-44ce-822a-172645112c72", "name": "load_p1rlv13677_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9aa7e62-8974-4ef0-aa5a-bcd545245aea"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "526c56c3-9921-4fa4-a847-f1aaf7e2bf36"}}}}, {"uuid": "d47e11d8-d612-4fd1-8682-c3435b00d0fa", "name": "38ec15b0-ee6b-4572-9bfb-3094e633a9c6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 12.611907582113087, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.885290064059574, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5adc2c36-14a6-47ba-8065-699e914c5cac", "name": "7715ca32-ff8b-41d5-b13e-652d37d6fbba", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d47e11d8-d612-4fd1-8682-c3435b00d0fa"}}}]}, {"uuid": "30eb92bc-4c73-40a8-b189-220ec402e1a5", "name": "load_p1rlv13677_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9aa7e62-8974-4ef0-aa5a-bcd545245aea"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5adc2c36-14a6-47ba-8065-699e914c5cac"}}}}, {"uuid": "13171c16-3766-48a6-b85d-fce1b4c23608", "name": "f1180b47-ce6c-459c-83e7-24fe85daf4e6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6b7e05ca-5d8d-4687-9c91-c46be0e94393", "name": "ced260df-4a12-44dd-880b-4d67e0c60293", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "13171c16-3766-48a6-b85d-fce1b4c23608"}}}]}, {"uuid": "b60bbcc8-db1c-4b2c-9ab8-17791087b760", "name": "load_p1rlv13678_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32b75c61-4e97-4e21-a786-8aab7a2d88f8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6b7e05ca-5d8d-4687-9c91-c46be0e94393"}}}}, {"uuid": "b62f2251-d24d-45e7-980e-ef4d9b47a504", "name": "1c1f827a-7066-412b-bf61-608d040d4916_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "56ae25bf-98c2-4005-ac11-543cc9eddeb7", "name": "d22d54e4-5e52-4472-8bf7-9a78ff6df048", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b62f2251-d24d-45e7-980e-ef4d9b47a504"}}}]}, {"uuid": "a0329e2e-1fa6-46e3-824e-c7da00ff962b", "name": "load_p1rlv13678_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32b75c61-4e97-4e21-a786-8aab7a2d88f8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "56ae25bf-98c2-4005-ac11-543cc9eddeb7"}}}}, {"uuid": "1216f196-6d86-4e3b-bda0-7366a867f755", "name": "02fab3ec-855e-490e-896f-7a706d20c1d4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5877230897388055, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4388767979233367, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f958ad87-2a98-4e6a-a293-8057d8fe389f", "name": "91e84414-0314-4efb-aba4-d8fed00ee89e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1216f196-6d86-4e3b-bda0-7366a867f755"}}}]}, {"uuid": "73b7d0ef-ca91-438c-868f-4ce161d78b94", "name": "load_p1rlv13679_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "284bbc5d-bb49-404d-823e-08ec543c90b8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f958ad87-2a98-4e6a-a293-8057d8fe389f"}}}}, {"uuid": "97ce0ac1-19b9-4960-8f86-e49ce43b4fdd", "name": "15a4960a-ad64-43bb-8715-67624839e8bb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5877230897388055, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4388767979233367, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a345b66d-51c6-4718-92d2-1e66017171ec", "name": "646d7312-411e-4fa8-8089-802c3b8ac94a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "97ce0ac1-19b9-4960-8f86-e49ce43b4fdd"}}}]}, {"uuid": "f5ffe810-c070-4042-bd16-a1d1047e555d", "name": "load_p1rlv13679_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "284bbc5d-bb49-404d-823e-08ec543c90b8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a345b66d-51c6-4718-92d2-1e66017171ec"}}}}, {"uuid": "c8b1c45d-d4d0-4928-935c-3866c5267d73", "name": "fc9cbd12-67da-4ddf-9e17-a4cc9d3d7a39_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "90e84820-53f8-4ec5-ab30-c1b8adeba609", "name": "a6367165-e64e-4785-83c4-49e85d650317", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c8b1c45d-d4d0-4928-935c-3866c5267d73"}}}]}, {"uuid": "0fb1c0b4-f597-4755-9070-7a24b5f8b93a", "name": "load_p1rlv13680_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85b910cd-def8-41d8-ad47-3c074a54ad8d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "90e84820-53f8-4ec5-ab30-c1b8adeba609"}}}}, {"uuid": "24e8ad5a-5435-4bd3-a930-36188d2f4313", "name": "0a87ea87-5580-41e4-a52e-41639b7d996c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ea4d6a04-3fdf-4e82-baad-0269aed2b904", "name": "996cd32f-f05e-4470-b8d1-10acdbd6854d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "24e8ad5a-5435-4bd3-a930-36188d2f4313"}}}]}, {"uuid": "21437a63-b495-4b76-876c-e5f86f7be7fc", "name": "load_p1rlv13680_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85b910cd-def8-41d8-ad47-3c074a54ad8d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ea4d6a04-3fdf-4e82-baad-0269aed2b904"}}}}, {"uuid": "6632eb7e-bae8-4711-8280-ac3a0a991206", "name": "28893ff5-412e-40a3-a212-52e2782d34ef_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "000ac7b0-24c3-4950-972d-e20658228342", "name": "8afd517a-a595-4d9f-b888-4b98d003878a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6632eb7e-bae8-4711-8280-ac3a0a991206"}}}]}, {"uuid": "369fe88d-458f-495d-a6fc-e2299dcaa1d3", "name": "load_p1rlv13681_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60f08cde-51d3-4b51-9ab5-b61c8043950f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "000ac7b0-24c3-4950-972d-e20658228342"}}}}, {"uuid": "73ed9a9b-8b1c-4d72-997d-3b3f06174e72", "name": "d307541e-6390-420b-90bc-c354842c8c4e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ad96ba65-d3c8-4412-a032-176eab395487", "name": "6105ce88-9320-477f-b2d2-85e6dd5ad86d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "73ed9a9b-8b1c-4d72-997d-3b3f06174e72"}}}]}, {"uuid": "82b351e5-a3aa-47e2-9520-cc902c46a692", "name": "load_p1rlv13681_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60f08cde-51d3-4b51-9ab5-b61c8043950f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ad96ba65-d3c8-4412-a032-176eab395487"}}}}, {"uuid": "865ddcf7-98d3-41f6-bf38-defee83d97b8", "name": "7ed0c62d-bcff-4b32-a663-d21ae0bf8ac3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5757409771642927, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7652901499575055, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "059b3c81-83a8-4bb0-8f63-a8de9452fb9b", "name": "4fffba48-2ddb-4844-95b5-c2808665038f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "865ddcf7-98d3-41f6-bf38-defee83d97b8"}}}]}, {"uuid": "629d17c4-bebd-48c9-879e-0c0e033ca412", "name": "load_p1rlv13682_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a3c050c-cc0d-460e-af02-ce3421431474"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "059b3c81-83a8-4bb0-8f63-a8de9452fb9b"}}}}, {"uuid": "1295811e-de6a-44ad-a13e-dda7e4e2cf61", "name": "9152cc72-9051-4239-b8f0-9b3dc8e0a72a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5757409771642927, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7652901499575055, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "591fd267-9404-4294-ae61-8c65df29bcb9", "name": "330bb019-c54a-4ecb-a332-7035a124455b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1295811e-de6a-44ad-a13e-dda7e4e2cf61"}}}]}, {"uuid": "47422c8c-3417-4dac-9c86-ffc9609bda7c", "name": "load_p1rlv13682_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a3c050c-cc0d-460e-af02-ce3421431474"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "591fd267-9404-4294-ae61-8c65df29bcb9"}}}}, {"uuid": "0db7c061-169a-4013-b150-b5f93a5140e5", "name": "b70b337e-55a5-4def-a326-eaaf47f57728_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5877230897388055, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4388767979233367, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "872b1bac-ff07-4d30-adf6-317dd41a1de5", "name": "2675fd69-b097-4d9b-9475-e2f3719c7a70", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0db7c061-169a-4013-b150-b5f93a5140e5"}}}]}, {"uuid": "668da774-22b3-42e2-a6b1-0280c9816f6a", "name": "load_p1rlv13683_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "de45dc59-3e0a-4b33-8cf4-d5213b0140c1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "872b1bac-ff07-4d30-adf6-317dd41a1de5"}}}}, {"uuid": "0e2ad523-f99c-4929-8d16-91ef3629506b", "name": "07fbfeaa-dc3a-4b54-b01e-0afb2c1c0371_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5877230897388055, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4388767979233367, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "54c1eeed-950d-4379-b00d-847f964c7ac4", "name": "d63dc4c7-07a6-4451-b606-6641acdcc48a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0e2ad523-f99c-4929-8d16-91ef3629506b"}}}]}, {"uuid": "ee5e2946-2306-4eaa-af5e-901222eea510", "name": "load_p1rlv13683_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "de45dc59-3e0a-4b33-8cf4-d5213b0140c1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "54c1eeed-950d-4379-b00d-847f964c7ac4"}}}}, {"uuid": "aa9fa668-8b5c-4c16-aa75-31f5d381c321", "name": "be235377-0688-4d31-a2cf-c9e6c94bc6e7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5202593896091736, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6973445820856009, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c859be38-862f-42d2-8694-e366a9f2128c", "name": "84e237c2-c2a7-4aa4-b35b-8229b8b5a493", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aa9fa668-8b5c-4c16-aa75-31f5d381c321"}}}]}, {"uuid": "f5fe6a40-9cf3-4744-bef2-05e7f64a97fc", "name": "load_p1rlv13684_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ec49353-14d1-4917-83bc-ca62cd94bf30"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c859be38-862f-42d2-8694-e366a9f2128c"}}}}, {"uuid": "2cd83c37-2373-4eda-af9a-c268cdd40bba", "name": "4b4456a7-c3f4-4a2e-88af-a0635f507705_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5202593896091736, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6973445820856009, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d89384a1-0e1f-41bf-8082-168c05d69b38", "name": "45cc88fb-5813-44e0-b1f4-9cd14a9451bc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2cd83c37-2373-4eda-af9a-c268cdd40bba"}}}]}, {"uuid": "6397bd60-fbca-423c-aaae-fe883c0a045e", "name": "load_p1rlv13684_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ec49353-14d1-4917-83bc-ca62cd94bf30"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d89384a1-0e1f-41bf-8082-168c05d69b38"}}}}, {"uuid": "c1bedbde-cb3b-48cf-83a8-2820a7cbe371", "name": "efdbfcfc-3608-4192-8ee7-1f4bfb75171f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3a9035cd-3ef0-4eb6-a016-ddba363a86a7", "name": "b77753f9-7255-4fa0-8139-9968b8f1520b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c1bedbde-cb3b-48cf-83a8-2820a7cbe371"}}}]}, {"uuid": "19754d34-82fa-46dd-84ee-d2646d6b799d", "name": "load_p1rlv13685_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f777bc74-e6f3-4e80-bb72-0764964db21e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3a9035cd-3ef0-4eb6-a016-ddba363a86a7"}}}}, {"uuid": "71467a1e-1ede-47b9-9bfd-85c4bac34c8f", "name": "4704cf25-87d5-43f7-83d1-c6088b025dd4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "36f533fa-a479-4daa-b3e0-5a2c5dbb51c3", "name": "3006d40c-9556-418a-aab0-e2444e2207a5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "71467a1e-1ede-47b9-9bfd-85c4bac34c8f"}}}]}, {"uuid": "3eabe4a1-6c61-4686-922c-e3a0e40af83e", "name": "load_p1rlv13685_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f777bc74-e6f3-4e80-bb72-0764964db21e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "36f533fa-a479-4daa-b3e0-5a2c5dbb51c3"}}}}, {"uuid": "94e6fa50-42fc-41e9-9abb-201d8e23d94f", "name": "fa86f889-dfcb-41a6-8f73-d9d7d90bf208_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ebee099f-241a-4c7d-b75d-2058d800889d", "name": "a9495890-1185-489f-b8c4-26fb7b1d0232", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "94e6fa50-42fc-41e9-9abb-201d8e23d94f"}}}]}, {"uuid": "91bc007c-1af6-48a0-a5e6-d8f0d37d137e", "name": "load_p1rlv13686_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60fe0a16-aa4d-4fe8-9f39-81bfa13b505f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ebee099f-241a-4c7d-b75d-2058d800889d"}}}}, {"uuid": "1112faee-e8b7-4260-880a-43e211c9ced0", "name": "39a3bdc6-ca82-438b-b699-d645d3ca387a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c9a78a4-19b6-4b48-9b0f-f5d183778f42", "name": "c339dea3-5781-414f-9f68-233cf2e25740", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1112faee-e8b7-4260-880a-43e211c9ced0"}}}]}, {"uuid": "d3c9ea73-77eb-488a-b9c1-b52499a39dba", "name": "load_p1rlv13686_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60fe0a16-aa4d-4fe8-9f39-81bfa13b505f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c9a78a4-19b6-4b48-9b0f-f5d183778f42"}}}}, {"uuid": "0f1e6ac0-70aa-4af0-a939-10d6bcc816b0", "name": "94db7979-8999-44bf-bf37-2b918522fb47_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4786893203254163, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3666592754227633, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8de6b990-1453-4ed8-abf9-d39634ea2aee", "name": "dacc3adb-a90c-4aea-b34a-559baea1c165", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0f1e6ac0-70aa-4af0-a939-10d6bcc816b0"}}}]}, {"uuid": "62d4d493-6a6b-41cd-ba20-e0f18e875b39", "name": "load_p1rlv13687_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4671f981-e26e-4f26-9698-7f9068ce6dec"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8de6b990-1453-4ed8-abf9-d39634ea2aee"}}}}, {"uuid": "332f9759-59a9-4733-84d5-01ddeb74945d", "name": "ab8b8986-c290-4ceb-8151-476952ad0e4f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4786893203254163, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3666592754227633, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "df94fbb6-0cd0-4e7a-8a43-22c6ff208d97", "name": "bc05459c-41f7-465c-a4a3-e1c5fd8cec2a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "332f9759-59a9-4733-84d5-01ddeb74945d"}}}]}, {"uuid": "29645c13-d3d0-4b4c-bbbf-afd5222598a3", "name": "load_p1rlv13687_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4671f981-e26e-4f26-9698-7f9068ce6dec"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "df94fbb6-0cd0-4e7a-8a43-22c6ff208d97"}}}}, {"uuid": "bd4ddb24-8e29-4b96-af3b-96f25a7494de", "name": "1319ad49-c4e4-44ac-9f97-597c74220ab2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7344cd86-6533-4184-a373-c02ab9549fca", "name": "332dc737-3c56-4c9e-bef6-ea2937774ea8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bd4ddb24-8e29-4b96-af3b-96f25a7494de"}}}]}, {"uuid": "4e62be72-5efb-4974-b102-b27fd9db4d5a", "name": "load_p1rlv13689_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e5db11f-0418-4119-9c71-26619456fd7b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7344cd86-6533-4184-a373-c02ab9549fca"}}}}, {"uuid": "5f414c6b-8fd3-4126-bd2a-bb61f3c48abe", "name": "d83021b0-7f17-4b5c-b199-976f49090c11_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "efbe0b52-16e1-4632-9ca6-3f01d3a7c2f6", "name": "4ccaf277-0aec-4dce-bdd6-8036eab4f00f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5f414c6b-8fd3-4126-bd2a-bb61f3c48abe"}}}]}, {"uuid": "392ed64a-44d5-409a-bcb8-7b53d7cb16be", "name": "load_p1rlv13689_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e5db11f-0418-4119-9c71-26619456fd7b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "efbe0b52-16e1-4632-9ca6-3f01d3a7c2f6"}}}}, {"uuid": "3200f720-b710-45ce-9dcf-f6448fe8fb4f", "name": "6f5a230a-2bc8-448d-ad0c-ca40306ac670_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "63d99ad2-499f-4001-8c6b-02d3b68cf97a", "name": "57e7ef2c-f725-4c38-a0d1-37ad2dc3eecf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3200f720-b710-45ce-9dcf-f6448fe8fb4f"}}}]}, {"uuid": "9530d4ad-f493-4ae8-b3f2-3e303d647d75", "name": "load_p1rlv13690_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "71c26ca3-0d61-46b8-a95b-710e0b760b62"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "63d99ad2-499f-4001-8c6b-02d3b68cf97a"}}}}, {"uuid": "7823cc66-5ff2-4c20-ab5d-91512e9d2c41", "name": "833ab35f-38f3-4673-b957-be716b6dcec7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2e2346ec-1d8b-496c-8acb-0feed9154b43", "name": "b15f16e7-cad3-4f3e-ae5f-129f399a4890", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7823cc66-5ff2-4c20-ab5d-91512e9d2c41"}}}]}, {"uuid": "bf76abe8-4b18-41e3-af4e-b76279eb2699", "name": "load_p1rlv13690_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "71c26ca3-0d61-46b8-a95b-710e0b760b62"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2e2346ec-1d8b-496c-8acb-0feed9154b43"}}}}, {"uuid": "e1737a50-5fd7-4b33-870f-d5b087c76427", "name": "fb5a4aa2-45c2-4ab6-9c67-965f1b1d50cb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7ba0cafd-5471-4410-a509-d82014858abd", "name": "ac7f08f8-7179-400f-9966-1643b06fc540", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e1737a50-5fd7-4b33-870f-d5b087c76427"}}}]}, {"uuid": "4b3eeef6-2fdc-4483-9a15-7d8a4f1f2ed0", "name": "load_p1rlv13691_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "850df31b-ee95-4903-93b7-6e5911e8f8a0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7ba0cafd-5471-4410-a509-d82014858abd"}}}}, {"uuid": "2ae22984-622d-4a1d-85f5-ce7064c1ae74", "name": "3cc735fc-385d-43f0-a35a-333df4a3392b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "124668c6-413a-4b80-bdda-2c889f127fc4", "name": "18b11031-e37c-4533-a5ae-8f60821f73cd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2ae22984-622d-4a1d-85f5-ce7064c1ae74"}}}]}, {"uuid": "24ccb9aa-e453-4fad-a5c8-1e8a306ff1eb", "name": "load_p1rlv13691_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "850df31b-ee95-4903-93b7-6e5911e8f8a0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "124668c6-413a-4b80-bdda-2c889f127fc4"}}}}, {"uuid": "3df4c39e-8ae1-4947-b3bc-19df9c776026", "name": "f6f6fdb3-fe43-4c07-8b28-4962430c7165_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.1140699739098325, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.0691290550182753, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9644c026-329a-4a1f-998b-60ece9776419", "name": "1f5df881-3b77-4b4a-bd21-a995d244dd40", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3df4c39e-8ae1-4947-b3bc-19df9c776026"}}}]}, {"uuid": "92ded483-725f-40c6-84b3-98a6015cec71", "name": "load_p1rlv13692_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "091b545a-eb31-4bea-a0a6-5aa9c7a8397f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9644c026-329a-4a1f-998b-60ece9776419"}}}}, {"uuid": "d509bf1b-6112-4ef3-8154-002006554632", "name": "8079b172-9551-4da3-afd7-57c2a2d1d119_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.1140699739098325, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.0691290550182753, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "272b06f6-e51d-4f01-8e44-3e9511586061", "name": "f002eb9c-8fd9-40ef-bda6-b972d6ca4b2b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d509bf1b-6112-4ef3-8154-002006554632"}}}]}, {"uuid": "e1bfcb4c-83c9-4e63-a718-ede158d8b3a9", "name": "load_p1rlv13692_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "091b545a-eb31-4bea-a0a6-5aa9c7a8397f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "272b06f6-e51d-4f01-8e44-3e9511586061"}}}}, {"uuid": "f549d4ee-7d2c-458a-8865-413d3613ff12", "name": "eb9d67ed-dbaf-4e6a-aa5f-36a91f666e0b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e41d8d1c-8dd4-4bf2-a16c-50fca8aa045e", "name": "2830747a-ac37-40dc-8c02-935d3b9912ec", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f549d4ee-7d2c-458a-8865-413d3613ff12"}}}]}, {"uuid": "d55f90b8-e894-4da7-860a-3958326632e3", "name": "load_p1rlv13693_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5815b75-1226-4221-9bcb-bc75ce85fa17"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e41d8d1c-8dd4-4bf2-a16c-50fca8aa045e"}}}}, {"uuid": "476a69e1-a9e0-4928-b7f3-552cc90bf303", "name": "38c60878-bd82-4df7-848f-9985598f5fe7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "655ebaf4-0818-4331-ae7d-7146bedafebc", "name": "1ab0c66e-95fd-4115-80fd-a9db9b12c908", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "476a69e1-a9e0-4928-b7f3-552cc90bf303"}}}]}, {"uuid": "149e6a50-bc4c-437f-9e56-86146effe61a", "name": "load_p1rlv13693_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5815b75-1226-4221-9bcb-bc75ce85fa17"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "655ebaf4-0818-4331-ae7d-7146bedafebc"}}}}, {"uuid": "a62dc22d-1f8d-46b2-8556-ca0dc332c559", "name": "8e6a59bb-fad2-4318-9066-580c5077702b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8bd92f03-a0f4-48ce-9b3d-09bffcd2412d", "name": "6557eb3f-9fea-4473-a24d-7b4ce0e44fc6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a62dc22d-1f8d-46b2-8556-ca0dc332c559"}}}]}, {"uuid": "4a37d94a-f80d-47e0-b65b-01e2960318e1", "name": "load_p1rlv13694_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1de2ebf2-3207-4bf7-9702-4c729d99a6cf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8bd92f03-a0f4-48ce-9b3d-09bffcd2412d"}}}}, {"uuid": "71d8bcb0-42da-4718-bf2d-e7d363ead5c4", "name": "a96590fd-adbb-41d9-a01a-98631e5a4933_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aa9a819d-caee-485b-88bf-f4ae3727b769", "name": "b739da1c-6f92-41cb-81d2-12f6cbf701d1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "71d8bcb0-42da-4718-bf2d-e7d363ead5c4"}}}]}, {"uuid": "9b9c8591-0453-4c68-bf4a-37c70b29ae2f", "name": "load_p1rlv13694_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1de2ebf2-3207-4bf7-9702-4c729d99a6cf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aa9a819d-caee-485b-88bf-f4ae3727b769"}}}}, {"uuid": "09c4d5f1-71c4-469b-8603-f1b25c00d631", "name": "4c485e30-41bd-4083-8717-dbc40101c2f3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.17188390355877, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.554870220420769, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a3ee682c-b1c7-44c4-bff6-a4d8acad378c", "name": "d6029c33-cd14-49e9-888f-548ed4366560", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "09c4d5f1-71c4-469b-8603-f1b25c00d631"}}}]}, {"uuid": "4f0a34ae-c8fc-44bd-9c7c-c804db865c3b", "name": "load_p1rlv13695_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d73963d7-acf4-48b3-8e54-6ee9f403d36f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a3ee682c-b1c7-44c4-bff6-a4d8acad378c"}}}}, {"uuid": "a14f6598-dcf3-4222-aff9-03aa785c3232", "name": "7324e4d5-eff6-4b91-8842-ad45bb36e2fb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.17188390355877, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.554870220420769, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "38fd2fc8-af2c-4375-bb14-2735753fd5ba", "name": "01c38178-5c60-4a27-b3b1-b8c4762989e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a14f6598-dcf3-4222-aff9-03aa785c3232"}}}]}, {"uuid": "ae6c0fd0-d614-4c0f-90ef-5fc0b3295f59", "name": "load_p1rlv13695_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d73963d7-acf4-48b3-8e54-6ee9f403d36f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "38fd2fc8-af2c-4375-bb14-2735753fd5ba"}}}}, {"uuid": "5eb73892-27e2-4054-8588-b0de1be5cdee", "name": "a3430b8f-8606-44be-b936-cc51b83628d6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.170918611307458, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.575413421893771, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e031df21-cbfa-4b1e-8a85-d904674671a8", "name": "a35ed688-1237-412d-8710-5425de3c9f82", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5eb73892-27e2-4054-8588-b0de1be5cdee"}}}]}, {"uuid": "cab9456a-bb12-404e-a3a4-c1d4a783098f", "name": "load_p1rlv13696_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f92273c9-90b8-4819-b036-9d69afb5aed6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e031df21-cbfa-4b1e-8a85-d904674671a8"}}}}, {"uuid": "ae2a96b5-8402-4705-b3ef-47eb2956246d", "name": "aebf8306-45df-47e3-8094-e02d25e14710_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.170918611307458, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.575413421893771, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "545bb6e9-937c-4335-8831-35cbfa5fc324", "name": "b7f7404f-11dd-4e22-8878-ad6ae3c5a2ca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ae2a96b5-8402-4705-b3ef-47eb2956246d"}}}]}, {"uuid": "0125f75c-efd6-4957-8ac0-1e8d533a3b87", "name": "load_p1rlv13696_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f92273c9-90b8-4819-b036-9d69afb5aed6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "545bb6e9-937c-4335-8831-35cbfa5fc324"}}}}, {"uuid": "483eaae2-214c-421b-b39c-b03f28d630fe", "name": "6bfb24b7-09c7-4f6c-a33c-d67aea19d82a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2370181650987906, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5806603708512078, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6e1fad86-4bfd-4d5f-8057-b77f7ec6b87f", "name": "6872893f-2e86-4889-9cf0-3945d3f9b966", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "483eaae2-214c-421b-b39c-b03f28d630fe"}}}]}, {"uuid": "fe5131a4-e117-4bfc-8606-a1410341e010", "name": "load_p1rlv13697_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c808261e-a49e-4954-bdc4-a8b63d0ee25b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6e1fad86-4bfd-4d5f-8057-b77f7ec6b87f"}}}}, {"uuid": "8a9fb659-c0b2-49a0-9cbc-4c1489f3ddbd", "name": "e2f294d7-0cb7-467e-89cf-090a4f35106e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2370181650987906, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5806603708512078, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b6121fa9-05bb-4af6-ace7-6219736b9224", "name": "e6ad07be-0efa-4e50-8ae6-c3e29b1d6a86", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a9fb659-c0b2-49a0-9cbc-4c1489f3ddbd"}}}]}, {"uuid": "05f1dfea-f98f-4ad7-b5f1-125332718265", "name": "load_p1rlv13697_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c808261e-a49e-4954-bdc4-a8b63d0ee25b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b6121fa9-05bb-4af6-ace7-6219736b9224"}}}}, {"uuid": "994053b2-2dcd-4e45-99c1-0143b8d3a3f4", "name": "9633f640-6a82-4afc-8062-185d65b30729_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cac11212-2c59-40b9-a2a9-c754625bb9fe", "name": "38b59a81-9591-40cb-ab35-f1578767f4a6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "994053b2-2dcd-4e45-99c1-0143b8d3a3f4"}}}]}, {"uuid": "cf7355e4-9d2e-4ae6-9384-4cbac3892452", "name": "load_p1rlv13698_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3839c291-3f45-46c3-973f-6a9615fcf81b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cac11212-2c59-40b9-a2a9-c754625bb9fe"}}}}, {"uuid": "48520c39-4eb5-43e5-86ce-ee13fd69508b", "name": "879b2b6d-5a7e-43a3-b01d-cf1172000d71_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1a354e32-b9f7-48a2-9d67-16babb502626", "name": "62fd14d7-3f51-4606-8237-98874714c9e6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "48520c39-4eb5-43e5-86ce-ee13fd69508b"}}}]}, {"uuid": "3be1397a-8a05-4668-9b09-656b568aab4b", "name": "load_p1rlv13698_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3839c291-3f45-46c3-973f-6a9615fcf81b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1a354e32-b9f7-48a2-9d67-16babb502626"}}}}, {"uuid": "29c3eb53-e8e6-434d-b8b9-b5d0eeeef957", "name": "f2b3afb2-d9d1-4df0-bc47-cb542a352e1a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9800785435301127, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2597629929517743, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "efea7d55-d9c3-40d8-9974-1ec710094411", "name": "fdc6bcae-ed53-44fc-a78d-8e226ddf0975", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "29c3eb53-e8e6-434d-b8b9-b5d0eeeef957"}}}]}, {"uuid": "78ea114e-84ee-4615-baf9-4817aefbf5b8", "name": "load_p1rlv13700_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ecf9ee9-2a3c-431b-84c8-02c7c7aaacb1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "efea7d55-d9c3-40d8-9974-1ec710094411"}}}}, {"uuid": "3ac6bc75-465b-42b3-852e-eeb5e2d1037e", "name": "501c5d20-904e-4849-b8b3-9edea9c96d6e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9800785435301127, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2597629929517743, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "396a415b-295f-4d6d-962d-c35b69dbfb00", "name": "6233a0aa-0d77-4a61-a4d0-eea1dbb1ac97", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3ac6bc75-465b-42b3-852e-eeb5e2d1037e"}}}]}, {"uuid": "e240f08b-a2bd-43ef-9bc3-418489941ef9", "name": "load_p1rlv13700_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ecf9ee9-2a3c-431b-84c8-02c7c7aaacb1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "396a415b-295f-4d6d-962d-c35b69dbfb00"}}}}, {"uuid": "c7596c6f-33bf-4ce8-94b7-ce8450625e3e", "name": "7fa0faeb-9e91-41c9-a0ee-8f12863cd6ec_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.547211686956079, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18814377021524833, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e3af9236-7fa2-4281-89b0-939b2cc9f155", "name": "dc89826e-cbd4-4e83-a5dd-8763bef64cb9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c7596c6f-33bf-4ce8-94b7-ce8450625e3e"}}}]}, {"uuid": "eb4e4727-b4f0-46ec-826a-dbb1737983cb", "name": "load_p1rlv13701_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa7a324e-d367-49a5-820a-b18e72243265"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e3af9236-7fa2-4281-89b0-939b2cc9f155"}}}}, {"uuid": "64f28cd5-6b3a-49ee-b88b-876bf0d5f347", "name": "a33c02eb-f545-461b-bc95-84d092c7914e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.547211686956079, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18814377021524833, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "83710f86-c125-4c89-92ad-3a6ded5b40b9", "name": "e727b800-0e89-42c7-8c25-e590764f428a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "64f28cd5-6b3a-49ee-b88b-876bf0d5f347"}}}]}, {"uuid": "deae30e2-4d1e-4e45-92b3-0d11ee422fcb", "name": "load_p1rlv13701_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa7a324e-d367-49a5-820a-b18e72243265"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "83710f86-c125-4c89-92ad-3a6ded5b40b9"}}}}, {"uuid": "700b9b2f-11c3-4d94-b9b7-14206f86098b", "name": "ec7828bd-32bf-4859-b88f-9d00dbada00e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "13bab12d-d6b7-45e9-ba69-182dcf8a0a9b", "name": "741e51a1-eebf-437e-91ba-84cc74e720fc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "700b9b2f-11c3-4d94-b9b7-14206f86098b"}}}]}, {"uuid": "6a27aee9-62a0-48e0-a446-8b3d4f3219e7", "name": "load_p1rlv13702_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fe3c958-296f-4b51-8b2b-74bb34ddb5a6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "13bab12d-d6b7-45e9-ba69-182dcf8a0a9b"}}}}, {"uuid": "a9754e34-ddf1-4994-8ce0-4913a3e58681", "name": "b0090678-8998-4d48-a463-dd05e6730437_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "936f4ea1-214f-4414-8b34-6ce0bf9879d7", "name": "54c22d49-2d81-4419-89f9-1ad89c5904de", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a9754e34-ddf1-4994-8ce0-4913a3e58681"}}}]}, {"uuid": "b405cc7f-aac6-4979-b0e8-4bc67aaf6e2e", "name": "load_p1rlv13702_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fe3c958-296f-4b51-8b2b-74bb34ddb5a6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "936f4ea1-214f-4414-8b34-6ce0bf9879d7"}}}}, {"uuid": "ad6f3996-5250-4903-900c-98cc80721468", "name": "e8a90a05-9c86-433f-a9ad-9ad3bb2f8b82_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2769071780208345, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4029118207034132, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "95c019d8-e7bf-4afd-a080-a6f621649229", "name": "05eeeca4-83c7-4501-b26c-d31da230df29", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ad6f3996-5250-4903-900c-98cc80721468"}}}]}, {"uuid": "3dab6f65-4632-4a3b-b353-50d00476b9c7", "name": "load_p1rlv13703_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9efacf5-5b96-4670-b6f1-dc398485cde9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "95c019d8-e7bf-4afd-a080-a6f621649229"}}}}, {"uuid": "97c46857-975d-412a-a4e0-5809874f5c16", "name": "ecb942cd-9b32-4043-b0e8-dc7a236faee7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2769071780208345, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4029118207034132, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f5e1e662-9c2f-48a5-85fb-d172280f7787", "name": "a31d2e6f-e64f-4b3d-b7d7-d3bb98c08c73", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "97c46857-975d-412a-a4e0-5809874f5c16"}}}]}, {"uuid": "bcb30f07-f390-431a-9ff8-0cde94b4035a", "name": "load_p1rlv13703_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9efacf5-5b96-4670-b6f1-dc398485cde9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f5e1e662-9c2f-48a5-85fb-d172280f7787"}}}}, {"uuid": "67e20fc8-11d1-4dc4-b232-49a9104fdd94", "name": "ddfc1f7d-1036-4cfa-9a48-fa1ba44fd782_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5d75438e-9f5d-481a-973d-ae138fa0337f", "name": "5fc81374-3427-4e96-8835-d0eb39e298a4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "67e20fc8-11d1-4dc4-b232-49a9104fdd94"}}}]}, {"uuid": "3b180503-e355-4f5c-9e1e-c2dca49a1d38", "name": "load_p1rlv13705_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f409299-5ac0-4f31-a217-d0aef7fbc4d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5d75438e-9f5d-481a-973d-ae138fa0337f"}}}}, {"uuid": "4b785ece-1a3a-4873-93a0-aaff723e54ea", "name": "26668d8a-2dbe-4359-a6bb-451d9a76228c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0b47fcab-65b9-4a82-b1bb-a2a21beb6138", "name": "903b60ff-3b21-4883-8b18-faae551c3d75", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4b785ece-1a3a-4873-93a0-aaff723e54ea"}}}]}, {"uuid": "284635fd-7a8a-4cf2-b20e-40b17b78ba7b", "name": "load_p1rlv13705_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f409299-5ac0-4f31-a217-d0aef7fbc4d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0b47fcab-65b9-4a82-b1bb-a2a21beb6138"}}}}, {"uuid": "c19162f1-9baa-4f3a-8e29-091896a65a63", "name": "44433df7-721c-49f3-9d4a-3f79a6898b62_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "49ba3689-a5c8-4f05-88d4-29a5f9a32264", "name": "bc6dd17f-97b0-46bb-b18d-a96ac1e78365", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c19162f1-9baa-4f3a-8e29-091896a65a63"}}}]}, {"uuid": "6ffcabfc-6189-4923-9459-f810143a516a", "name": "load_p1rlv13706_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e60fc98a-9c1d-4975-a9b9-e37271b4ac81"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "49ba3689-a5c8-4f05-88d4-29a5f9a32264"}}}}, {"uuid": "43c584f4-0f3c-4289-bee3-b8198dccaf4d", "name": "4807c297-4619-4dbb-ac3a-93b5cd05776e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ee8dd868-18b6-4d0f-881b-f0cc44f0ca24", "name": "d7cfc5db-df8b-4faa-ab3e-40d38ee914fa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "43c584f4-0f3c-4289-bee3-b8198dccaf4d"}}}]}, {"uuid": "bc3cf296-500e-48df-8860-073864e4dd2b", "name": "load_p1rlv13706_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e60fc98a-9c1d-4975-a9b9-e37271b4ac81"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ee8dd868-18b6-4d0f-881b-f0cc44f0ca24"}}}}, {"uuid": "6413e194-03e5-48c7-88a6-50f535f3a72a", "name": "ff48c4d2-8b8a-42b7-8b13-547e96dc9bd6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1f78e963-e9df-4f71-b59b-b7020b109583", "name": "7e30d6c4-12cd-4aab-8b47-451df08c4733", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6413e194-03e5-48c7-88a6-50f535f3a72a"}}}]}, {"uuid": "e95cd4c6-356c-4db2-be42-22421b873317", "name": "load_p1rlv13707_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "286623b3-af08-4a60-896a-1f5b85fe04a5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1f78e963-e9df-4f71-b59b-b7020b109583"}}}}, {"uuid": "3366db9e-3cf3-4151-8361-83b441a1f30e", "name": "22f79fb6-2b63-4702-ab85-effb7f238529_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a0851e07-4737-49ff-84ad-daa6bc98b911", "name": "694b01b0-174c-47ff-8dd6-2ba5e1fe9d3d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3366db9e-3cf3-4151-8361-83b441a1f30e"}}}]}, {"uuid": "56d76667-0cdd-48ef-a18b-ed51d5d65d1e", "name": "load_p1rlv13707_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "286623b3-af08-4a60-896a-1f5b85fe04a5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a0851e07-4737-49ff-84ad-daa6bc98b911"}}}}, {"uuid": "75952726-7480-4eb3-8fca-e410a5609a32", "name": "1171d848-94aa-4d3f-85e2-f6b2a083abf4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "66c585a7-9929-4d9e-b2c0-4038ef131727", "name": "97b55cae-aa0a-4c34-987e-efdb2ef1e497", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "75952726-7480-4eb3-8fca-e410a5609a32"}}}]}, {"uuid": "49afa33d-2db8-4c25-baf0-db76d22a5b78", "name": "load_p1rlv13708_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a230534-6927-4af8-ba54-6ab4c9c32d21"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "66c585a7-9929-4d9e-b2c0-4038ef131727"}}}}, {"uuid": "6f76b578-9e6c-4143-9fa1-0a9d00e81721", "name": "58d582ca-d92e-49a9-afa0-3d49ad5ddf68_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "75a5498f-0a83-4d9a-a17e-bdde0fccc40d", "name": "3842aa62-58e8-4549-b39a-ef1b378b39d4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6f76b578-9e6c-4143-9fa1-0a9d00e81721"}}}]}, {"uuid": "e17a4e5a-76ab-4e2b-9deb-0ddc2436202c", "name": "load_p1rlv13708_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a230534-6927-4af8-ba54-6ab4c9c32d21"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "75a5498f-0a83-4d9a-a17e-bdde0fccc40d"}}}}, {"uuid": "b23ca2b3-f01b-4a70-9c20-3ef8d65883bc", "name": "92063d80-548f-4737-aba3-d38c65b55fda_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "58ee1ba5-d4cd-483f-b539-6f48b5664106", "name": "620fd620-3af1-4383-9614-c5fa3611b9b6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b23ca2b3-f01b-4a70-9c20-3ef8d65883bc"}}}]}, {"uuid": "6bd8147e-4da1-41f0-ab34-81bf5be88280", "name": "load_p1rlv13711_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2bfaa34-267c-4dfd-8b6d-4ab444ac4048"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "58ee1ba5-d4cd-483f-b539-6f48b5664106"}}}}, {"uuid": "b216556a-58a2-4ff4-b485-d2e41df9d5c5", "name": "46df789e-0b71-4086-9338-f9f9abed9eea_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6508feb2-672c-4f09-bedf-352defe69273", "name": "8a7044d2-9623-4090-9535-7b77ebdfd4e1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b216556a-58a2-4ff4-b485-d2e41df9d5c5"}}}]}, {"uuid": "29ab3c31-513d-4ba8-92a0-46a0df8c64dc", "name": "load_p1rlv13711_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2bfaa34-267c-4dfd-8b6d-4ab444ac4048"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6508feb2-672c-4f09-bedf-352defe69273"}}}}, {"uuid": "6418ab48-9339-4497-855a-b597731a1243", "name": "cc53d833-c02e-462e-aaa6-5805e0b3df3b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7545306166330135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0868234997236217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "146c8f5e-86e7-4955-9415-724b425e7d92", "name": "b490587e-dcfa-48bf-bb38-9da514ff2a94", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6418ab48-9339-4497-855a-b597731a1243"}}}]}, {"uuid": "ff3b22fc-25ef-4ea2-ad20-a01769dd6228", "name": "load_p1rlv13712_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ab8bce-7c02-4c7b-962e-3fb44a3ab7a9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "146c8f5e-86e7-4955-9415-724b425e7d92"}}}}, {"uuid": "97ab516e-1b75-4db4-a02f-2a3e534364ed", "name": "edbd1e33-e791-41c6-adbf-15ff89ddf2f5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7545306166330135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0868234997236217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4f328d12-489d-4a0a-ac22-c15f688ebf38", "name": "cf4b514d-e94c-426f-ac7e-479f28cfb2ed", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "97ab516e-1b75-4db4-a02f-2a3e534364ed"}}}]}, {"uuid": "6bd90a3f-7030-4ebd-8435-2deaa7b3287c", "name": "load_p1rlv13712_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ab8bce-7c02-4c7b-962e-3fb44a3ab7a9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4f328d12-489d-4a0a-ac22-c15f688ebf38"}}}}, {"uuid": "aa2897bb-6c94-4c97-beed-05beeab0409b", "name": "7eb4941e-aab2-4b82-97d4-e5a1bea33332_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fd3fa0fb-eefc-44ed-bd10-dbc69cc69dbd", "name": "409fecca-9d80-4bfd-a225-8e9f1fa11b15", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aa2897bb-6c94-4c97-beed-05beeab0409b"}}}]}, {"uuid": "01e08a61-f12d-44e2-97f7-d9d92ef0dd55", "name": "load_p1rlv13713_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee766a99-bb6f-4d5c-8513-9d462103f6fc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fd3fa0fb-eefc-44ed-bd10-dbc69cc69dbd"}}}}, {"uuid": "72227943-9753-4764-89fd-9a52b2ff60b7", "name": "992e2843-abba-4520-b23a-1ae2deee57db_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c853f8ef-2cf1-4a41-8fb3-40148f6182d7", "name": "e07790a4-62ba-4aad-9b20-dee50a745a9d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72227943-9753-4764-89fd-9a52b2ff60b7"}}}]}, {"uuid": "d6d84b9a-453c-41d6-a1fc-e90bfc7c4af3", "name": "load_p1rlv13713_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee766a99-bb6f-4d5c-8513-9d462103f6fc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c853f8ef-2cf1-4a41-8fb3-40148f6182d7"}}}}, {"uuid": "754509b2-e93c-4cc1-ba8e-8f881a1b87e6", "name": "fcfdc003-f539-4d06-97f6-74b531454884_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9972586284721718, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5405993695804993, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8e3a8735-5c81-4955-ade7-ef788305f464", "name": "d85f1cf8-8756-4671-afc2-58fc47a83939", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "754509b2-e93c-4cc1-ba8e-8f881a1b87e6"}}}]}, {"uuid": "4618bcd0-4a49-42cb-a947-1ad974ae77c8", "name": "load_p1rlv13714_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17936036-1191-4f91-bc12-2298db7b77e3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8e3a8735-5c81-4955-ade7-ef788305f464"}}}}, {"uuid": "b47fcbac-90fa-4e88-97c5-2a030255e0c9", "name": "7d7b8d24-c368-427a-a6c5-39287240dca0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9972586284721718, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5405993695804993, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "98e26e6f-9bb9-4e70-8144-92a64d3fff47", "name": "be31ff26-26d7-4011-b6e4-9a2d9c7656d3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b47fcbac-90fa-4e88-97c5-2a030255e0c9"}}}]}, {"uuid": "6a9508d2-1734-48c3-8444-79bb54072e1b", "name": "load_p1rlv13714_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17936036-1191-4f91-bc12-2298db7b77e3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "98e26e6f-9bb9-4e70-8144-92a64d3fff47"}}}}, {"uuid": "9e151eb7-5f81-440f-974d-fe976df01299", "name": "1d91d7eb-1e63-4f9f-b435-1197599db6d1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "57633dc2-dcd6-4729-a316-4e096ed1f292", "name": "36e71770-34f7-46bb-afd0-ed2986df6ca6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9e151eb7-5f81-440f-974d-fe976df01299"}}}]}, {"uuid": "c812a679-890c-4d0f-98d9-0d1f7d45f99d", "name": "load_p1rlv13715_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a822fdb0-b531-49b0-89da-b517e5ae6e3a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "57633dc2-dcd6-4729-a316-4e096ed1f292"}}}}, {"uuid": "92649058-d744-41bd-91d4-969ee02e3557", "name": "71d0b39e-c5df-4efb-b9d0-b7bb3e2d3f60_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f2dfe100-e76c-4b08-ab10-7eafc439ced1", "name": "d7fb2e79-b36a-4da1-9450-e76fda612f21", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "92649058-d744-41bd-91d4-969ee02e3557"}}}]}, {"uuid": "5523e36f-b164-4cd1-b47f-790f9d2080f0", "name": "load_p1rlv13715_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a822fdb0-b531-49b0-89da-b517e5ae6e3a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f2dfe100-e76c-4b08-ab10-7eafc439ced1"}}}}, {"uuid": "6fcedadc-5687-4d32-801f-41ea8517173a", "name": "b9c70ccf-2ea5-4a70-8329-c5a5c75154eb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0fb544c1-e897-425d-9c92-9a04c78144f4", "name": "5b8ab658-643d-4572-9f87-1dfc56ee539d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6fcedadc-5687-4d32-801f-41ea8517173a"}}}]}, {"uuid": "9373a3d8-431a-4e5b-bc97-72b35793721a", "name": "load_p1rlv13716_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb3b4207-12ad-46e6-b4de-59149a46f8a1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0fb544c1-e897-425d-9c92-9a04c78144f4"}}}}, {"uuid": "6c990dc3-9aae-434f-be73-936224343e7d", "name": "a1327074-a0dd-4963-980d-8c1955fa3f43_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "07876a8a-aef7-4bb8-83b4-1ce723379caa", "name": "e9b74712-8026-4896-b0d9-748f9f85c33b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c990dc3-9aae-434f-be73-936224343e7d"}}}]}, {"uuid": "0d8ddad1-6cb5-490c-a4a7-08840429a56d", "name": "load_p1rlv13716_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb3b4207-12ad-46e6-b4de-59149a46f8a1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "07876a8a-aef7-4bb8-83b4-1ce723379caa"}}}}, {"uuid": "7b4d227c-71c5-44be-a753-27a2e2d3c822", "name": "d7ba2655-5d70-485e-a3e2-d7dab97b4ffb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "083c693f-7451-4a82-98a6-fd33ae600b7a", "name": "254e231c-54d2-4360-84e4-cb99d595c499", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b4d227c-71c5-44be-a753-27a2e2d3c822"}}}]}, {"uuid": "40c3c225-3dc3-4e2a-8cb6-a855fc0d6d40", "name": "load_p1rlv13717_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdbfe616-f51f-416a-94ce-6e676d300226"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "083c693f-7451-4a82-98a6-fd33ae600b7a"}}}}, {"uuid": "5fd7b8b0-61ac-48cd-ab38-7094e02b1c97", "name": "fd0f1747-45ce-40d0-b4b5-2f8db2d3681c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d98c18a0-87e8-428f-a555-1a94776ba879", "name": "db0912c1-87b2-4d95-b1f8-28ada67f3122", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5fd7b8b0-61ac-48cd-ab38-7094e02b1c97"}}}]}, {"uuid": "0015d220-ad70-47b2-b3a3-4672d57385af", "name": "load_p1rlv13717_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdbfe616-f51f-416a-94ce-6e676d300226"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d98c18a0-87e8-428f-a555-1a94776ba879"}}}}, {"uuid": "25542898-6b2c-4f16-af7d-d7b082c9a12a", "name": "385d9c16-4654-417c-b777-7aa08f6a082a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6027984746974515, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12293402966163972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4632ff26-1435-4900-8c24-064f89444d78", "name": "ae548c79-9b0f-4aec-bbd3-caf8815c145e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "25542898-6b2c-4f16-af7d-d7b082c9a12a"}}}]}, {"uuid": "e97f8a95-0a85-4426-a5d7-bf700b901a92", "name": "load_p1rlv13719_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44aa3f37-e0db-4050-b47f-ac14b7fa6534"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4632ff26-1435-4900-8c24-064f89444d78"}}}}, {"uuid": "0ead7666-1788-4c58-9475-78f07dbfb2c7", "name": "ad3f2d2e-c3ce-4ceb-b06e-a313b53c404b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6027984746974515, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12293402966163972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4f684ec0-59a6-4e94-8609-46ee2f369b86", "name": "93bf93cf-51e3-4a04-bcd7-07e3527deb4e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0ead7666-1788-4c58-9475-78f07dbfb2c7"}}}]}, {"uuid": "0c2ba3a8-52db-4453-98c3-67ef3943039d", "name": "load_p1rlv13719_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44aa3f37-e0db-4050-b47f-ac14b7fa6534"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4f684ec0-59a6-4e94-8609-46ee2f369b86"}}}}, {"uuid": "065ac14e-ad43-4f8a-83bc-458d5a376d9e", "name": "2cfb0ada-7713-4150-b59c-1764af325937_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.693271865954936, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.115673740909077, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f032b135-567f-41e1-8f02-30eeb30cae74", "name": "2cfb0ada-7713-4150-b59c-1764af325937_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.693271865954936, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.115673740909077, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f66981dc-9a7f-4d48-9c9a-d014312e2040", "name": "2cfb0ada-7713-4150-b59c-1764af325937_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.693271865954936, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.115673740909077, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8b79ad69-4cec-4070-b217-a724f6a87163", "name": "18df2ab4-f102-49e3-b6d5-46c286393f54", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "065ac14e-ad43-4f8a-83bc-458d5a376d9e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f032b135-567f-41e1-8f02-30eeb30cae74"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f66981dc-9a7f-4d48-9c9a-d014312e2040"}}}]}, {"uuid": "40539eb5-04a1-47e8-a33d-f250c4efcda6", "name": "load_p1rlv13720", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fe1a5da7-bdac-46a6-ab32-addc4f02a296"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8b79ad69-4cec-4070-b217-a724f6a87163"}}}}, {"uuid": "a4bea439-76cd-4468-a365-8b99869e18b0", "name": "ff334ece-0414-4a5d-978d-16814908ce78_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.498014754859445, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0be10e40-addc-44a0-95b8-17c2667d64b0", "name": "865d928c-09a8-4aa7-89d9-5402b1f98597", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a4bea439-76cd-4468-a365-8b99869e18b0"}}}]}, {"uuid": "4532d3a3-933d-4350-bf56-5f09d7e02f59", "name": "load_p1rlv13721_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6097c903-70fc-4635-a66c-fee2243ba545"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0be10e40-addc-44a0-95b8-17c2667d64b0"}}}}, {"uuid": "cf061642-a570-42d7-b6a1-bda4f7bf11ad", "name": "376a1a9f-7a87-4dc5-8f2b-c2e69d99aedb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.498014754859445, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2f0f3560-d5e9-45dc-8fa1-57c4492d0228", "name": "b2f84c5f-390e-4a57-b294-a258c93c856b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cf061642-a570-42d7-b6a1-bda4f7bf11ad"}}}]}, {"uuid": "e2a2af36-b6fb-44d1-9b8d-8a541a55cbc9", "name": "load_p1rlv13721_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6097c903-70fc-4635-a66c-fee2243ba545"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2f0f3560-d5e9-45dc-8fa1-57c4492d0228"}}}}, {"uuid": "cbaebd38-060c-47f8-a31d-82317d5498d4", "name": "8400bf58-7f39-43b7-8782-b26400ae2afa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0772156037646567, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.01984596164170695, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "adb63022-7bff-420c-9630-a71369c1173d", "name": "93f5ad57-9582-470d-b478-7cf205431bde", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cbaebd38-060c-47f8-a31d-82317d5498d4"}}}]}, {"uuid": "5913b235-7f23-44d3-9bed-4855db1ffb03", "name": "load_p1rlv13723_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0f1846b-2515-48ef-9241-0276932f8e75"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "adb63022-7bff-420c-9630-a71369c1173d"}}}}, {"uuid": "63a5c690-9991-4d51-b11e-65fa0936739c", "name": "e646f638-eead-4a67-a015-aabf77b9dfdd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0772156037646567, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.01984596164170695, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a4afb26a-6c9f-4511-b59f-42dc4d6fc4b6", "name": "fbda14f5-a977-4076-bac2-a87ecd3c5a6b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "63a5c690-9991-4d51-b11e-65fa0936739c"}}}]}, {"uuid": "4978d1b9-2594-4bf0-af8d-9600ad7d7685", "name": "load_p1rlv13723_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0f1846b-2515-48ef-9241-0276932f8e75"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a4afb26a-6c9f-4511-b59f-42dc4d6fc4b6"}}}}, {"uuid": "3b053fe4-7517-4e8b-a5db-7c0200c5301f", "name": "09d2550e-5249-4897-86b2-15f06064b6df_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6277722044378486, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6969686665668667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7370b0bd-80cd-433b-9192-bc43c5e1a7be", "name": "7c3ad141-20bd-4f8a-ae12-33ad20556a42", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3b053fe4-7517-4e8b-a5db-7c0200c5301f"}}}]}, {"uuid": "a45714a0-7b14-4206-955f-80f8c450db3d", "name": "load_p1rlv13724_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "457c6c9d-5020-4cf3-9c1e-c36012a619d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7370b0bd-80cd-433b-9192-bc43c5e1a7be"}}}}, {"uuid": "58a76492-a584-4280-918a-07b715d387df", "name": "7b59b86e-a70a-42ac-a0ac-c35549727ff6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6277722044378486, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6969686665668667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a143659c-ad8d-4069-a8e5-cb7f495a2ab8", "name": "ddac1d04-e4a4-4508-b483-e46fc85dcad2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58a76492-a584-4280-918a-07b715d387df"}}}]}, {"uuid": "2f81c172-7861-4ac1-8635-9c7b7be1eea0", "name": "load_p1rlv13724_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "457c6c9d-5020-4cf3-9c1e-c36012a619d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a143659c-ad8d-4069-a8e5-cb7f495a2ab8"}}}}, {"uuid": "4f7e210b-8657-4907-afb0-2fdeb6ad39f8", "name": "7f12debb-47ea-4b10-814d-ebf7df7088b1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4699462180170992, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3815978523472859, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f722faea-19a7-4445-a5ba-aabe9951ae25", "name": "91821276-4178-4e96-9357-2242c8f18dcf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4f7e210b-8657-4907-afb0-2fdeb6ad39f8"}}}]}, {"uuid": "b3032777-00a4-4e8d-b124-8e1154386c77", "name": "load_p1rlv13725_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e290046b-c936-4f51-b4ef-632bf572ab7f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f722faea-19a7-4445-a5ba-aabe9951ae25"}}}}, {"uuid": "0e7e24f0-18d9-4954-a6ec-adedf0f98db4", "name": "fadc48c3-d531-4be2-b3d2-977404485f0c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4699462180170992, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3815978523472859, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "16112990-2183-48fd-b59c-e1c31239ab37", "name": "01c5727b-1947-47bd-aa23-129b2373e7f0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0e7e24f0-18d9-4954-a6ec-adedf0f98db4"}}}]}, {"uuid": "ecf2d690-b53e-409e-bd12-3fe278a4a408", "name": "load_p1rlv13725_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e290046b-c936-4f51-b4ef-632bf572ab7f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "16112990-2183-48fd-b59c-e1c31239ab37"}}}}, {"uuid": "ea59716e-ff02-4fe0-96c9-98334af45343", "name": "ccb1f4b6-7666-40ab-805b-387e4127deff_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.559543722017981, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7101531402521069, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "024d4b5b-caec-4dd8-9523-0dd3f77ec616", "name": "77ee0385-e9d9-4ce9-9814-3f1f72612aa2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ea59716e-ff02-4fe0-96c9-98334af45343"}}}]}, {"uuid": "a1074246-39b6-4a84-9bb3-bab5de04efcb", "name": "load_p1rlv13726_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "642597e6-fe60-442f-b356-2be6f21677b2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "024d4b5b-caec-4dd8-9523-0dd3f77ec616"}}}}, {"uuid": "8097c180-7252-4a8f-a0c2-31caa4e0bcd5", "name": "d5075581-9fed-4669-a63b-22e5f594bb9f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.559543722017981, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7101531402521069, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1612c2b3-272a-438e-a8a2-9c070b656f67", "name": "f41c0c3f-0dbb-445c-89f4-14d751b99d4c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8097c180-7252-4a8f-a0c2-31caa4e0bcd5"}}}]}, {"uuid": "772e3056-1184-4bbd-8456-11bb88f849a8", "name": "load_p1rlv13726_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "642597e6-fe60-442f-b356-2be6f21677b2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1612c2b3-272a-438e-a8a2-9c070b656f67"}}}}, {"uuid": "570b274f-388c-4c5e-8765-e1f43c2d99c8", "name": "a73059bb-e437-48a1-a2e4-b6ea38a2ec24_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.70898089652498, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7830599711618245, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a3e04680-3dfe-4696-aa2f-3d698a557628", "name": "914c2206-d850-42aa-9034-897718169bba", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "570b274f-388c-4c5e-8765-e1f43c2d99c8"}}}]}, {"uuid": "32c8420d-bc08-4ddf-8ad2-5c1a91750b99", "name": "load_p1rlv13727_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36019623-eb62-412c-a591-41494980c9b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a3e04680-3dfe-4696-aa2f-3d698a557628"}}}}, {"uuid": "045e5b4c-a5d1-493d-b89f-abaec81c479b", "name": "595944c9-4275-4c6a-8559-118d0090546e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.70898089652498, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7830599711618245, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1f4e5df6-c5db-4a5d-8c90-987416e54d98", "name": "923d034c-aa7d-4a9f-b117-fc14c9d85510", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "045e5b4c-a5d1-493d-b89f-abaec81c479b"}}}]}, {"uuid": "23ec0f8d-ad28-4acf-833c-91ed0581460c", "name": "load_p1rlv13727_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36019623-eb62-412c-a591-41494980c9b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1f4e5df6-c5db-4a5d-8c90-987416e54d98"}}}}, {"uuid": "2f09022f-95e8-4f03-94eb-632b3deb5bb2", "name": "5e42c9ef-4052-4d9d-96a7-e6436c2a4815_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 12.611907582113087, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.885290064059574, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c9f56e64-a595-48aa-a382-bcb537d235f4", "name": "e80b2ee4-a8a5-4d22-b5bb-257be53e5acc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2f09022f-95e8-4f03-94eb-632b3deb5bb2"}}}]}, {"uuid": "9a416140-7041-43b6-b2bd-25ee741cb466", "name": "load_p1rlv13728_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9657a993-0005-4ffc-8c9f-18e80a491070"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c9f56e64-a595-48aa-a382-bcb537d235f4"}}}}, {"uuid": "6835f5d8-a666-42d4-9f3f-4c86fe3ed12a", "name": "cac9a18c-75a4-4d56-a1cd-2880d62c8486_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 12.611907582113087, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.885290064059574, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "053915d4-d4ac-42e4-b303-1e25bbde93b1", "name": "2f2112f0-e24c-4a82-9929-c3bc07c98c09", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6835f5d8-a666-42d4-9f3f-4c86fe3ed12a"}}}]}, {"uuid": "92fc514e-a83d-4451-935b-c49f7cee00a2", "name": "load_p1rlv13728_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9657a993-0005-4ffc-8c9f-18e80a491070"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "053915d4-d4ac-42e4-b303-1e25bbde93b1"}}}}, {"uuid": "0b48ddbd-a8b0-489e-9867-ef8439109a26", "name": "9297ef60-e9ea-4582-843d-ca70d318c44d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.028781788264419, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6709073147144231, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "12d5a0f8-56fc-40b7-8f45-1bf67557aee7", "name": "a105314f-aa53-4476-942b-c5766d404511", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0b48ddbd-a8b0-489e-9867-ef8439109a26"}}}]}, {"uuid": "e2fe9658-1741-473a-bd57-9eb0b2f3485f", "name": "load_p1rlv13784_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01a18948-75cf-4caf-951f-17a9c8d1f6bc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "12d5a0f8-56fc-40b7-8f45-1bf67557aee7"}}}}, {"uuid": "7306ded9-8b69-4dbe-86d5-7ea4fb33190c", "name": "086b660b-e051-4ebe-8a74-ed7483f89e33_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.028781788264419, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6709073147144231, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e85fd6fb-5334-49b7-8a84-405c8bb4daa7", "name": "9494e3dd-556a-41ff-a9ef-3612c4ae268e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7306ded9-8b69-4dbe-86d5-7ea4fb33190c"}}}]}, {"uuid": "d4e8b427-9fc7-4230-85f4-304d66ccd6c9", "name": "load_p1rlv13784_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01a18948-75cf-4caf-951f-17a9c8d1f6bc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e85fd6fb-5334-49b7-8a84-405c8bb4daa7"}}}}, {"uuid": "ae3335b0-295f-42bf-9b0d-e8c237fc40ce", "name": "4060d010-a34b-4f61-8baf-4b0fe8cf82ab_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7293ed3d-db31-4b0f-84ed-e1072d29fbec", "name": "fb539322-9819-40d4-b232-831a1dde2861", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ae3335b0-295f-42bf-9b0d-e8c237fc40ce"}}}]}, {"uuid": "e8de7c85-8abc-4098-92f1-6c262259c9af", "name": "load_p1rlv13792_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc5fcb56-435a-4a0d-b442-7489a98ad1cd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7293ed3d-db31-4b0f-84ed-e1072d29fbec"}}}}, {"uuid": "d2033207-79e4-41b4-872b-3ed0e60c5126", "name": "d4f5c4fa-ad8a-4e7b-a6ca-6797dbe1c260_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "be6d7968-c8a6-4621-aded-3efc1b5efcdf", "name": "042507ee-5a14-4ec3-9d92-871b2b26fa62", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d2033207-79e4-41b4-872b-3ed0e60c5126"}}}]}, {"uuid": "474c83a9-55f4-443c-b6fd-1267c438ab86", "name": "load_p1rlv13792_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc5fcb56-435a-4a0d-b442-7489a98ad1cd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "be6d7968-c8a6-4621-aded-3efc1b5efcdf"}}}}, {"uuid": "5b948bc6-9a04-4795-bfa9-01eb6d87861c", "name": "f74d6c3d-0371-4640-ab31-1c93d9435f40_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1648375907215343, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4430202395847888, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3757cab6-2ee7-4a95-9d71-ee3846d99760", "name": "f29f50b2-b0c2-4aac-9fb3-11b6e10eacf8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b948bc6-9a04-4795-bfa9-01eb6d87861c"}}}]}, {"uuid": "729053e2-f61f-4ddf-a62e-79e8d78caee2", "name": "load_p1rlv13794_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9725b6c-5bac-456a-bb6a-ce16a5e6b1a5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3757cab6-2ee7-4a95-9d71-ee3846d99760"}}}}, {"uuid": "22f8b219-1ab3-4775-8009-4d45ab313fe2", "name": "cf79beb3-0468-457c-93c0-5927e700c10b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1648375907215343, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4430202395847888, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e19d4fa9-8881-432a-96f0-f4c01ce935d6", "name": "3a35aef1-8f52-4b9f-8de2-b4a9e23b2983", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "22f8b219-1ab3-4775-8009-4d45ab313fe2"}}}]}, {"uuid": "1a73fa78-912f-42a0-b075-c5e4f8e75dab", "name": "load_p1rlv13794_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9725b6c-5bac-456a-bb6a-ce16a5e6b1a5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e19d4fa9-8881-432a-96f0-f4c01ce935d6"}}}}, {"uuid": "2b094398-1b00-4649-8d7d-ec234c2cddf5", "name": "62c30933-adac-4a05-b9f2-bee562077aa1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9518333270985427, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3340330193202704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3f11dbf6-443f-4bdf-aee0-650b675953bc", "name": "9a000fbc-b2e7-4a6c-9203-504fefd68405", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2b094398-1b00-4649-8d7d-ec234c2cddf5"}}}]}, {"uuid": "88688a62-05b0-48d5-a2fc-b720e3b3611e", "name": "load_p1rlv13797_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65052833-aec9-4363-a0cf-4d70fa9bb0ce"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3f11dbf6-443f-4bdf-aee0-650b675953bc"}}}}, {"uuid": "b9ce6736-7aa9-4e91-a962-bf314292f154", "name": "85fdcf94-c44a-429f-aab8-c3604ee2a35e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9518333270985427, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3340330193202704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1e15fbf3-d3eb-46e6-9043-f08cba648a41", "name": "72e7bea1-9154-4c38-b781-660b6f0b1f12", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b9ce6736-7aa9-4e91-a962-bf314292f154"}}}]}, {"uuid": "b7f8b025-5f44-4628-aebc-fb733bf3a827", "name": "load_p1rlv13797_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65052833-aec9-4363-a0cf-4d70fa9bb0ce"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1e15fbf3-d3eb-46e6-9043-f08cba648a41"}}}}, {"uuid": "d008dff8-0eca-43b2-a489-dddf1259f8b1", "name": "8263be69-f301-49f1-ad74-aff7cea45575_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.661093206685493, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9884186563142763, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2c148610-e18e-42ff-86f5-86f7e7d46e1c", "name": "33001303-0875-48b6-9db5-97731631a2ce", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d008dff8-0eca-43b2-a489-dddf1259f8b1"}}}]}, {"uuid": "1c9bbfba-9960-4261-8309-cf060c9695a0", "name": "load_p1rlv13805_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83d60921-a1f2-4b9c-9709-d2be59b82db5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2c148610-e18e-42ff-86f5-86f7e7d46e1c"}}}}, {"uuid": "d99dc7bf-d409-4931-8fca-5f94a2b89c2d", "name": "f1db1921-7c69-4ceb-a463-94b278426670_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.661093206685493, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9884186563142763, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "46ebd613-17d9-427f-9c79-d5e5beeb5dec", "name": "98235c32-1c83-4c03-8da0-0d2c93bd8a2a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d99dc7bf-d409-4931-8fca-5f94a2b89c2d"}}}]}, {"uuid": "f1119480-14dc-4bfe-bc02-83f47b1c6f79", "name": "load_p1rlv13805_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83d60921-a1f2-4b9c-9709-d2be59b82db5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "46ebd613-17d9-427f-9c79-d5e5beeb5dec"}}}}, {"uuid": "f99e86d1-f09c-4c75-a62c-86a281b8e3de", "name": "b85266ba-b80c-4fd8-a566-d2195631ff4e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4464370236076721, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16599396793014964, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bf53e031-d4a6-48aa-a830-5c127fd126cb", "name": "c7f377ac-0f6f-45f4-94d6-62ce97af7fd5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f99e86d1-f09c-4c75-a62c-86a281b8e3de"}}}]}, {"uuid": "b310fa6b-3561-4f44-8c02-3fe5845177b1", "name": "load_p1rlv13811_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aef2ef8-706c-4316-be01-0707ddf0ac7c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bf53e031-d4a6-48aa-a830-5c127fd126cb"}}}}, {"uuid": "54c9112e-beac-4376-98fb-29a9fcd58369", "name": "497ad5bf-510b-454f-8e94-b0e25fc99de0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4464370236076721, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16599396793014964, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3f6629e0-d2f9-4154-9736-947e7689538b", "name": "72b40a6b-934a-44df-974f-5f432dfb5ea5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "54c9112e-beac-4376-98fb-29a9fcd58369"}}}]}, {"uuid": "4ae17924-c7b0-46b0-96b7-eb50d517392e", "name": "load_p1rlv13811_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aef2ef8-706c-4316-be01-0707ddf0ac7c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3f6629e0-d2f9-4154-9736-947e7689538b"}}}}, {"uuid": "bdab4977-8247-45c9-b12d-2c32d8ab1531", "name": "dd9d5f22-24e3-4e93-822d-9f8855946932_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4868228207229564, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16976956391895093, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ec7818b8-f415-4595-9286-203cafa19f52", "name": "3406079d-61de-4f6a-98e0-94b3c6186342", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bdab4977-8247-45c9-b12d-2c32d8ab1531"}}}]}, {"uuid": "d85187ab-becb-484f-9857-aa2f29732078", "name": "load_p1rlv13812_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ffd737b-a273-4a6c-91c6-351b5719f658"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ec7818b8-f415-4595-9286-203cafa19f52"}}}}, {"uuid": "bedef87c-cbc5-4343-8474-fdc4146c18ef", "name": "ccd49114-65bb-46d0-b5bf-20327daf6b3a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4868228207229564, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16976956391895093, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a33faf8d-ee17-4d08-ae59-f31c6d3430b7", "name": "e985d90e-4301-48f8-ac94-7932b0618b99", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bedef87c-cbc5-4343-8474-fdc4146c18ef"}}}]}, {"uuid": "2f70ad94-00e8-4947-9e08-561f3609687b", "name": "load_p1rlv13812_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ffd737b-a273-4a6c-91c6-351b5719f658"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a33faf8d-ee17-4d08-ae59-f31c6d3430b7"}}}}, {"uuid": "4ec6c000-17d6-4c00-bb2f-69d9421922fb", "name": "ed2a0538-3156-40d4-ba8a-b0061f7ae68a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2596055778412756, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4460523908595607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b3f55c19-e53c-43aa-b18a-7806debc8e10", "name": "fcfe9690-2ba1-4777-8755-0e648a44743e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4ec6c000-17d6-4c00-bb2f-69d9421922fb"}}}]}, {"uuid": "23a8dfde-cdf0-451c-b9bc-aee846edd2e6", "name": "load_p1rlv14434_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06135bd7-6a77-4f04-a439-4ce8c245447d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b3f55c19-e53c-43aa-b18a-7806debc8e10"}}}}, {"uuid": "50ec0c20-f152-4fd9-bdc8-ee03a07ede22", "name": "32214626-4faa-45ff-abe3-5416beeae5df_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2596055778412756, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4460523908595607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "37ced1c4-aaba-4f1f-85f2-327c2445e6f8", "name": "5f0e1323-82cf-4eed-9712-6fd2cc97e929", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "50ec0c20-f152-4fd9-bdc8-ee03a07ede22"}}}]}, {"uuid": "0a8f122e-7a9a-482f-a8c6-baeea7a29ca9", "name": "load_p1rlv14434_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06135bd7-6a77-4f04-a439-4ce8c245447d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "37ced1c4-aaba-4f1f-85f2-327c2445e6f8"}}}}, {"uuid": "2d0e31de-a0df-46f1-af90-1b937b60ca43", "name": "7cbf61d5-0ee4-47ce-9378-2b7d7c9764b9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.904546554088597, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7711735109904765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1aa2825e-0efd-4844-a72b-6df0455193e5", "name": "3c187500-8a3f-4463-8769-bf684e0c7eaf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2d0e31de-a0df-46f1-af90-1b937b60ca43"}}}]}, {"uuid": "081fe3c5-fef8-4a22-bc81-65e9d2728088", "name": "load_p1rlv14435_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d07f5065-df41-484d-8e8a-80b2ff4e0e9b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1aa2825e-0efd-4844-a72b-6df0455193e5"}}}}, {"uuid": "471a413f-2eaa-4197-bece-c67b603b162a", "name": "8ee074cf-d8bd-40db-acdd-38204fd9aa91_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.904546554088597, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7711735109904765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b734a13b-49ba-4216-981a-a1c26b8442c2", "name": "17d0d18e-bb91-411a-b7f1-b8ea738d3cfb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "471a413f-2eaa-4197-bece-c67b603b162a"}}}]}, {"uuid": "99d1a71f-f989-47fc-9f83-39b676d187bd", "name": "load_p1rlv14435_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d07f5065-df41-484d-8e8a-80b2ff4e0e9b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b734a13b-49ba-4216-981a-a1c26b8442c2"}}}}, {"uuid": "5e9875d5-2bd2-4a80-9fb0-5aa1837a67ca", "name": "f7f82c80-17c7-4f51-b255-1e93d8e027cc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.756100999166533, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1794980420068588, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "80d5b990-bd78-4ae5-a3b9-1d77a3da445b", "name": "7445fd14-5983-48a7-87ca-6e5659032878", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5e9875d5-2bd2-4a80-9fb0-5aa1837a67ca"}}}]}, {"uuid": "b9f752a7-b6e4-405d-add0-812f294bcf81", "name": "load_p1rlv14436_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad66e41a-88ab-443e-b10e-9e7b5b899119"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "80d5b990-bd78-4ae5-a3b9-1d77a3da445b"}}}}, {"uuid": "aff84010-8b8c-4a7f-9d4c-2c43694a952c", "name": "dbbbf139-0f95-48f5-acaa-086e1c44c25d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.756100999166533, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1794980420068588, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5cf4d181-0b70-4419-be75-5d3190cb1735", "name": "bef3bd59-9ee9-45c6-abb9-3fb7e9de4705", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aff84010-8b8c-4a7f-9d4c-2c43694a952c"}}}]}, {"uuid": "5564228d-f485-4130-86a3-04573a3e29b9", "name": "load_p1rlv14436_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad66e41a-88ab-443e-b10e-9e7b5b899119"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5cf4d181-0b70-4419-be75-5d3190cb1735"}}}}, {"uuid": "0dbe7793-0d47-4fe5-b038-3b999b242fae", "name": "4750cf80-9c97-4274-a712-b73798096b15_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7653657521185364, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4426471780914222, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3b82e80a-6324-40d2-b374-9db33fa5ef57", "name": "594897a8-f6aa-4272-b22b-26448d576c26", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0dbe7793-0d47-4fe5-b038-3b999b242fae"}}}]}, {"uuid": "82aca4f2-6c5b-4bc0-aae2-b5a49a64d263", "name": "load_p1rlv14828_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9efa4c9-9832-4aa8-bf44-be0fe1e80cd5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3b82e80a-6324-40d2-b374-9db33fa5ef57"}}}}, {"uuid": "5903d2f9-91a7-435c-a8cb-1f11fb6a26a6", "name": "87761cbc-dbf1-499a-a572-16632761c2ef_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7653657521185364, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4426471780914222, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "68492e2a-6570-4bce-a33d-57f001e3234d", "name": "a6054e8b-ee23-467a-bcd2-bc1425d9c6de", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5903d2f9-91a7-435c-a8cb-1f11fb6a26a6"}}}]}, {"uuid": "4c2198f5-7b12-499e-8ed8-99d3054d67db", "name": "load_p1rlv14828_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9efa4c9-9832-4aa8-bf44-be0fe1e80cd5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "68492e2a-6570-4bce-a33d-57f001e3234d"}}}}, {"uuid": "2f9dd3b5-b8b8-4e57-b14a-7648ea564701", "name": "045a91b1-8843-4bc1-8108-7545409dc696_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1976836424562762, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1051220183522544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c44694fe-ec4b-4975-90d4-b20dfc47bfda", "name": "27abf23f-031c-4ff8-a27f-946c42b90b7d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2f9dd3b5-b8b8-4e57-b14a-7648ea564701"}}}]}, {"uuid": "62705e48-23c3-40f1-ba30-985371f037f0", "name": "load_p1rlv14908_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d73b0321-e181-4ecd-b431-9aa6985d56d0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c44694fe-ec4b-4975-90d4-b20dfc47bfda"}}}}, {"uuid": "13973059-1455-492f-aa8d-4f0949f37171", "name": "de2f93d0-3b7f-47ef-847c-60e38ab38cf5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1976836424562762, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1051220183522544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c586f4c7-ef88-4352-8862-0775454adae6", "name": "41def184-fcb6-41ff-a21f-b6c96c5b1e91", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "13973059-1455-492f-aa8d-4f0949f37171"}}}]}, {"uuid": "5fb5c5f4-eb51-4b8f-964d-bda964502433", "name": "load_p1rlv14908_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d73b0321-e181-4ecd-b431-9aa6985d56d0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c586f4c7-ef88-4352-8862-0775454adae6"}}}}, {"uuid": "c451fcb3-16fc-4ab4-b742-9685f3c20147", "name": "046c2e5c-9bcd-49b7-985d-ff87924957d4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9dc3c26b-791e-418e-8438-ab88c139d380", "name": "793240ef-b02c-4623-b140-29599685560b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c451fcb3-16fc-4ab4-b742-9685f3c20147"}}}]}, {"uuid": "d353f84e-cf15-45cb-8dfe-3c455036fa82", "name": "load_p1rlv14952_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3c39b0c-9c92-4934-876f-ee5f542f95cc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9dc3c26b-791e-418e-8438-ab88c139d380"}}}}, {"uuid": "ada1f288-eb32-40fa-a93c-b178dc471a25", "name": "e6624cbc-01a1-4d75-a74d-6f51903b1cb6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7978430e-b47f-471e-abf3-c557209eb1af", "name": "71ca7f34-1f1f-4d74-b942-b183995d7a2b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ada1f288-eb32-40fa-a93c-b178dc471a25"}}}]}, {"uuid": "9c5c9761-f21a-4ed3-bbc7-c95e9ac88e6e", "name": "load_p1rlv14952_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3c39b0c-9c92-4934-876f-ee5f542f95cc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7978430e-b47f-471e-abf3-c557209eb1af"}}}}, {"uuid": "55ab0755-f6d0-4afe-a977-e9fe416d48e2", "name": "9a9b70aa-72c9-48c4-a97a-893f6c40a381_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.374506393438246, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.694445400364831, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0edb6602-5e0c-49db-af53-afaac6863971", "name": "81b0d1c0-35ef-4ae8-a27d-231ab99ead98", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "55ab0755-f6d0-4afe-a977-e9fe416d48e2"}}}]}, {"uuid": "ba37f6a9-d2e1-45fd-93f2-5592c7c07386", "name": "load_p1rlv14954_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9e128f5-eb18-44df-8ec4-35bd049ef630"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0edb6602-5e0c-49db-af53-afaac6863971"}}}}, {"uuid": "1b602400-59f5-47f9-9bde-fdaac8e37572", "name": "94af954a-5059-44d9-af06-f44215920afb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.374506393438246, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.694445400364831, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7b432e8c-65cf-4990-a136-2379e96e5e79", "name": "1ddba20c-906e-43c1-99f8-eb531288b44e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1b602400-59f5-47f9-9bde-fdaac8e37572"}}}]}, {"uuid": "3acda848-9982-497f-bebc-bed963f86579", "name": "load_p1rlv14954_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9e128f5-eb18-44df-8ec4-35bd049ef630"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7b432e8c-65cf-4990-a136-2379e96e5e79"}}}}, {"uuid": "faaf63ea-d3bd-4351-83df-e6a9432ebd55", "name": "6af9cafb-9b46-471d-a620-d791cde8077a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.749950841708346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2019248045205122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fc221dbf-f8e8-4ad9-bbf9-d8ae1e8a99f3", "name": "77966535-8c36-425a-9913-dcd3e54c7a90", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "faaf63ea-d3bd-4351-83df-e6a9432ebd55"}}}]}, {"uuid": "02ceef6f-f4f0-4a1d-bf34-d2b1cae4ccc5", "name": "load_p1rlv14974_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "884ff47e-8e20-4ae8-97bd-287d0ca9dc1b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fc221dbf-f8e8-4ad9-bbf9-d8ae1e8a99f3"}}}}, {"uuid": "a47ccb41-9101-4862-9919-266c22934ac6", "name": "41281d89-de87-494a-b10d-2065930fe40d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.749950841708346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2019248045205122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a7de7a39-b75c-496a-aa48-cac2e1e4e315", "name": "af67500e-fe6b-4ac5-b512-ab34bdc795d8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a47ccb41-9101-4862-9919-266c22934ac6"}}}]}, {"uuid": "935fef31-6064-44c6-b4e7-1d67031960e8", "name": "load_p1rlv14974_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "884ff47e-8e20-4ae8-97bd-287d0ca9dc1b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a7de7a39-b75c-496a-aa48-cac2e1e4e315"}}}}, {"uuid": "1c8a1050-9e99-4748-a965-b48dc79e1a7b", "name": "208ed43a-7564-4026-8572-a2af145b4198_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.446531565278448, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9314679219387375, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3d6ac767-6b08-40a3-afe2-fd754bdb6e44", "name": "6c859f0b-a1fc-46b5-9113-1bd2784ae024", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1c8a1050-9e99-4748-a965-b48dc79e1a7b"}}}]}, {"uuid": "e1739cc0-2f69-4dd4-8772-857e3b95a2da", "name": "load_p1rlv14992_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4f8b1bc-83c3-4819-9d98-9491df98d494"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3d6ac767-6b08-40a3-afe2-fd754bdb6e44"}}}}, {"uuid": "fa59870f-88a2-4890-9295-c01066faa555", "name": "b35a08ad-9702-4e0a-8707-72a6299a3d62_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.446531565278448, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9314679219387375, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a0f7b08-80b8-4e40-9c1f-5305c35720f2", "name": "f299f9be-c5b0-42ab-b5f5-5f804bd03d2f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fa59870f-88a2-4890-9295-c01066faa555"}}}]}, {"uuid": "9419b869-2e79-4f11-9b36-8a2d43f5ca86", "name": "load_p1rlv14992_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4f8b1bc-83c3-4819-9d98-9491df98d494"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0a0f7b08-80b8-4e40-9c1f-5305c35720f2"}}}}, {"uuid": "2d368127-8205-4442-9a21-37ee30d3f334", "name": "cab7b5f5-254d-4612-b29a-ee256010e346_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.667455481738122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8122169683202977, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f1435521-c53a-4628-ba0c-29fab58ef34f", "name": "424231c3-871e-42ab-b340-3810cde2a19c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2d368127-8205-4442-9a21-37ee30d3f334"}}}]}, {"uuid": "e519484b-3290-497d-8b32-be3a202acc1d", "name": "load_p1rlv15007_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc29de5b-3a3f-40c0-bde4-9a57f5f62b5c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f1435521-c53a-4628-ba0c-29fab58ef34f"}}}}, {"uuid": "af7b4c86-76f9-4a08-808b-3faf1fda48be", "name": "3dfb5887-53cb-4e9d-862f-0c648e2d0aae_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.667455481738122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8122169683202977, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "be2aac07-1e00-474e-a6c3-5451a234ac7d", "name": "633c8a6c-8ee7-43de-8e99-a75ffe5c6223", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "af7b4c86-76f9-4a08-808b-3faf1fda48be"}}}]}, {"uuid": "333f0478-984e-4add-baac-b5bded1c612d", "name": "load_p1rlv15007_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc29de5b-3a3f-40c0-bde4-9a57f5f62b5c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "be2aac07-1e00-474e-a6c3-5451a234ac7d"}}}}, {"uuid": "3b4a6592-f755-44ef-8cf2-2744c004d806", "name": "7df558ba-4f9b-4d05-802a-84fe6da2eba6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7847716543397305, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8567239737527961, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c10a1df-1289-4c5d-95cc-6ae363879d1b", "name": "f699cd67-9d6c-42de-af3e-3b5b25db4abf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3b4a6592-f755-44ef-8cf2-2744c004d806"}}}]}, {"uuid": "e796f84b-ec7a-4323-9053-423934ab8911", "name": "load_p1rlv15008_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19231152-1fd1-4e07-a5d9-603c765b2cae"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c10a1df-1289-4c5d-95cc-6ae363879d1b"}}}}, {"uuid": "155d9294-2026-4595-a10f-5d1d3370d942", "name": "d1ff1274-c897-4045-a6ab-1bc942556d49_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7847716543397305, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8567239737527961, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4cf1c416-9a98-4133-abfb-d14595d37519", "name": "58be0c17-d02f-4a51-81ea-eb67be621b58", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "155d9294-2026-4595-a10f-5d1d3370d942"}}}]}, {"uuid": "e4f20f75-2bf9-44b6-9665-9dcfd0831802", "name": "load_p1rlv15008_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19231152-1fd1-4e07-a5d9-603c765b2cae"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4cf1c416-9a98-4133-abfb-d14595d37519"}}}}, {"uuid": "88061b2d-03dd-4bef-b2aa-c5113d39db92", "name": "3d8d4048-7d53-47a2-9ff8-b98a7c5a734d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6848010607962993, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6615616037111118, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "33b2a2ec-137a-40da-bab7-0d9db8e29dba", "name": "2c8cc345-ec14-454c-a3df-7999de4b373e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "88061b2d-03dd-4bef-b2aa-c5113d39db92"}}}]}, {"uuid": "ef3cd349-73a6-4848-b20b-cdd1218fcd31", "name": "load_p1rlv15027_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07e3b847-cc9a-4f84-bc00-cb4396b6dea0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "33b2a2ec-137a-40da-bab7-0d9db8e29dba"}}}}, {"uuid": "0bb0048a-e1a5-4541-9c5b-7b1754279a93", "name": "36d9565b-932f-4eac-8928-c87b2db194cc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6848010607962993, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6615616037111118, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4010dd0f-be87-4210-ab11-20b47a6824f2", "name": "5a251cb6-cfea-45a4-a2ab-a30edaea99f1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0bb0048a-e1a5-4541-9c5b-7b1754279a93"}}}]}, {"uuid": "14061709-05d6-4809-a0fb-8de5dbb878c7", "name": "load_p1rlv15027_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07e3b847-cc9a-4f84-bc00-cb4396b6dea0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4010dd0f-be87-4210-ab11-20b47a6824f2"}}}}, {"uuid": "aa3ecebd-b7f6-453c-b107-f9de938836e8", "name": "18d1cbb6-315b-4ac8-8058-357d964badc0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.297417532176794, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2780703813036578, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "065b9b89-c7a5-42c6-a9ad-b1f750c56c53", "name": "23ed7327-4f19-48a3-b8ec-a1246c3101a3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aa3ecebd-b7f6-453c-b107-f9de938836e8"}}}]}, {"uuid": "abf89700-c23c-4f1f-9986-f9363dd66505", "name": "load_p1rlv15045_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "baccbdab-efc0-487d-b00d-38d3d4be57b4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "065b9b89-c7a5-42c6-a9ad-b1f750c56c53"}}}}, {"uuid": "e82a813c-40b1-4474-94ad-105922c9197a", "name": "be588434-76bf-42da-8db0-63712217a3ad_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.297417532176794, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2780703813036578, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6fdb5567-a8c7-45aa-9049-70c86ad648bf", "name": "892b9695-55fc-43ed-a900-4ad2df7299a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e82a813c-40b1-4474-94ad-105922c9197a"}}}]}, {"uuid": "5e9e9d33-d84f-422b-aec3-bd7049a99b07", "name": "load_p1rlv15045_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "baccbdab-efc0-487d-b00d-38d3d4be57b4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6fdb5567-a8c7-45aa-9049-70c86ad648bf"}}}}, {"uuid": "54f59e7b-dbde-4448-9adf-2c3b2b205aee", "name": "0d9b2913-0b05-4723-a677-45647949f9dd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3054635933061174, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.028189505661142127, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "35859e7f-0203-421f-b7e1-95a5d1f8bdad", "name": "5aabebba-312c-4cd1-9dcb-ab9c9f89edef", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "54f59e7b-dbde-4448-9adf-2c3b2b205aee"}}}]}, {"uuid": "7b61f36b-0fd8-4db1-8d5e-3bd2e69ded78", "name": "load_p1rlv15046_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2182c9fd-fd3d-4cb1-b525-192480823e2f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "35859e7f-0203-421f-b7e1-95a5d1f8bdad"}}}}, {"uuid": "d5da2654-9c5d-4151-b380-9a54ef5dff84", "name": "76b214c4-32dd-43ae-ae73-5a04d373e4c6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3054635933061174, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.028189505661142127, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fbcde39a-5be9-4ee4-a007-905fc48dd499", "name": "6d9364c1-db81-416b-bf4a-944575d28809", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d5da2654-9c5d-4151-b380-9a54ef5dff84"}}}]}, {"uuid": "c8817eda-96ee-4de0-974b-5a4ee8e2d700", "name": "load_p1rlv15046_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2182c9fd-fd3d-4cb1-b525-192480823e2f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fbcde39a-5be9-4ee4-a007-905fc48dd499"}}}}, {"uuid": "0ed66465-c93e-4bbc-b6d8-f8733570df59", "name": "d483b59c-359c-4b8a-b4ee-4bd199f54e33_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.605318582042619, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.38786447308176675, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82256a60-b4fc-44df-9a90-638422679924", "name": "019726b9-c3ea-4490-adab-f9f7dd742641", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0ed66465-c93e-4bbc-b6d8-f8733570df59"}}}]}, {"uuid": "399a3df4-6083-444d-9d10-92ade5bb7bbe", "name": "load_p1rlv15056_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a914ec3a-4883-42a7-b25d-133a1410b8d9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "82256a60-b4fc-44df-9a90-638422679924"}}}}, {"uuid": "f7a4e74b-d00d-493e-8ed3-48318ab6318d", "name": "74a33022-3750-4c48-9101-1b0b94dab6ab_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.605318582042619, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.38786447308176675, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5833379c-cf4a-404e-bc1f-c2005aa40cef", "name": "ddac8155-a00a-4162-849f-c9787c308814", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f7a4e74b-d00d-493e-8ed3-48318ab6318d"}}}]}, {"uuid": "e2c58061-9dbe-45ce-a721-8992f3b96cae", "name": "load_p1rlv15056_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a914ec3a-4883-42a7-b25d-133a1410b8d9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5833379c-cf4a-404e-bc1f-c2005aa40cef"}}}}, {"uuid": "084827a7-20ea-4302-b255-ff892f846062", "name": "45eed0da-500b-4355-8d8b-3fa3d64c28b7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.038374933892965, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6403266957226059, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c1901508-d644-40b5-af80-37c5ad1ef045", "name": "35ff5b24-e1f4-4870-8339-b09c76f3720c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "084827a7-20ea-4302-b255-ff892f846062"}}}]}, {"uuid": "3f51b6de-6dd3-4676-bb1e-e6b39419098e", "name": "load_p1rlv15064_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "366c9c98-59f1-46d5-b39c-4046703e5e4b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c1901508-d644-40b5-af80-37c5ad1ef045"}}}}, {"uuid": "5e1dd03d-0244-4a37-81c9-224edc02ae81", "name": "ee724805-ca62-43cc-b825-61971b140f9f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.038374933892965, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6403266957226059, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e51d4f22-e74d-40ed-b32e-1e608c2e9942", "name": "7e215efb-c2fa-4670-a122-ab9e908d23c0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5e1dd03d-0244-4a37-81c9-224edc02ae81"}}}]}, {"uuid": "85803038-b368-41b8-a135-3e5c87d7c73e", "name": "load_p1rlv15064_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "366c9c98-59f1-46d5-b39c-4046703e5e4b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e51d4f22-e74d-40ed-b32e-1e608c2e9942"}}}}, {"uuid": "7ef14852-87ee-49f6-a01e-3b2f0d54d045", "name": "7764dae3-4df1-4ec9-a275-9586e0c11678_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5369480608064634, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2969034126636569, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "392c267e-bbf0-4ebf-9128-1bb9f19f45c2", "name": "0e554282-ef8b-4bd7-9f95-bd3134747501", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7ef14852-87ee-49f6-a01e-3b2f0d54d045"}}}]}, {"uuid": "4c962874-3ff5-4ffd-9a2e-03dd51d5caa5", "name": "load_p1rlv15082_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a56b9ad8-c53b-4652-bf94-a7a7dfb8b306"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "392c267e-bbf0-4ebf-9128-1bb9f19f45c2"}}}}, {"uuid": "afd3dd67-a714-44d8-b648-025a873bcc66", "name": "9e168c79-e6f8-46e4-9b5f-308d69d2a3de_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5369480608064634, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2969034126636569, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d78aa811-e5de-47d2-8a6e-ca859e6d274d", "name": "8ffaefe2-8f9b-40ee-8efb-997d246a6f78", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "afd3dd67-a714-44d8-b648-025a873bcc66"}}}]}, {"uuid": "0e534536-98df-4d0e-a2b2-c57f662230ad", "name": "load_p1rlv15082_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a56b9ad8-c53b-4652-bf94-a7a7dfb8b306"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d78aa811-e5de-47d2-8a6e-ca859e6d274d"}}}}, {"uuid": "8a16342a-f4dc-49bc-a03d-0b6ef94b5c8a", "name": "2ee01cca-a911-4d27-b1f1-32145c9f8a0b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.694404982351279, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0468171481890831, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dce3bd76-dd92-4a29-bdae-8f511f6a66de", "name": "1ab69093-721c-4b03-a875-566ccccd6991", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a16342a-f4dc-49bc-a03d-0b6ef94b5c8a"}}}]}, {"uuid": "3ea19cfb-febf-4c3e-834f-4bb5374952c5", "name": "load_p1rlv15109_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "161d4e7b-30f2-447c-a369-1bfa3ba2cd70"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dce3bd76-dd92-4a29-bdae-8f511f6a66de"}}}}, {"uuid": "16f16d5b-6d41-4e21-8374-2b49c353e3ae", "name": "9ffa5173-e5de-4d02-98a8-40351f2d63c0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.694404982351279, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0468171481890831, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f06eae7f-b1db-45c7-8ec8-81018096d1ed", "name": "fc22c1f4-36ec-4c93-83d8-52906a7c3b5c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "16f16d5b-6d41-4e21-8374-2b49c353e3ae"}}}]}, {"uuid": "77da50e4-307b-46ce-9a51-879e6dc63b3e", "name": "load_p1rlv15109_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "161d4e7b-30f2-447c-a369-1bfa3ba2cd70"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f06eae7f-b1db-45c7-8ec8-81018096d1ed"}}}}, {"uuid": "31580ad3-7e99-4aa5-8204-f7f827d1ba17", "name": "451c0e75-b2d5-42a5-a87a-b70884307d2f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9518333270985427, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3340330193202704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "643ee3e6-5e93-441a-adb3-a7e109757722", "name": "e1085673-f52e-4199-b3d0-537d5669de47", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "31580ad3-7e99-4aa5-8204-f7f827d1ba17"}}}]}, {"uuid": "4370f7f8-8420-4bbe-a500-4e4c6f80e0ae", "name": "load_p1rlv15125_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb6d8f13-f04e-4b80-a8dc-e16af1dc860e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "643ee3e6-5e93-441a-adb3-a7e109757722"}}}}, {"uuid": "a85898a5-2e15-440e-b099-8b28ced7c56d", "name": "0308184c-c1ca-4b58-a025-7bfc339d1646_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9518333270985427, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3340330193202704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e72c23e9-be35-479c-b4ad-f19d089ff9f0", "name": "923523d9-abbf-4aa6-b18c-e9c265f73f11", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a85898a5-2e15-440e-b099-8b28ced7c56d"}}}]}, {"uuid": "b13aabec-dc96-44ec-aaeb-f00a782ba1b1", "name": "load_p1rlv15125_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb6d8f13-f04e-4b80-a8dc-e16af1dc860e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e72c23e9-be35-479c-b4ad-f19d089ff9f0"}}}}, {"uuid": "367fdd34-4284-448b-9b5b-14e8c663b7f4", "name": "87f0776a-0237-453d-ad1f-4eb39b4fea02_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.386602840079273, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.360256050049383, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "59541744-25fc-4a62-85f1-6fd5a167211e", "name": "df98da5e-a000-4aa1-873a-297a7e9fd7f6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "367fdd34-4284-448b-9b5b-14e8c663b7f4"}}}]}, {"uuid": "5ed7c0aa-1d90-4cb5-b068-f3bde5ccae4f", "name": "load_p1rlv15163_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdee6d84-9253-4fba-b713-3e41d706e999"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "59541744-25fc-4a62-85f1-6fd5a167211e"}}}}, {"uuid": "6a34efdc-e3cc-45b7-a203-7bf5b2c81eb8", "name": "5786607c-5f81-40a4-889f-ee57750faeb2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.386602840079273, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.360256050049383, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4f3a6f0a-3726-4ff0-9e98-0f1b860ef874", "name": "c46c090a-58bb-49eb-b6be-1396413b297f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6a34efdc-e3cc-45b7-a203-7bf5b2c81eb8"}}}]}, {"uuid": "ba90f2b2-b807-4a1a-b4d7-7610eb475222", "name": "load_p1rlv15163_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdee6d84-9253-4fba-b713-3e41d706e999"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4f3a6f0a-3726-4ff0-9e98-0f1b860ef874"}}}}, {"uuid": "0a6bd41f-0854-469a-bfba-2a896c3a06cd", "name": "2ff222e2-6676-45cd-91b2-7c319b22d5eb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0472938281946713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.40441110210881914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "94810cc7-42eb-448b-86bf-3e77db5adbf2", "name": "12e0771d-de5e-44a2-bf41-a3380bdb0e0b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0a6bd41f-0854-469a-bfba-2a896c3a06cd"}}}]}, {"uuid": "f4cdda81-b2ef-465c-a7ad-ab4debb3e111", "name": "load_p1rlv15170_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d2f8fcb-c279-49d5-88be-39e6a1d1990b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "94810cc7-42eb-448b-86bf-3e77db5adbf2"}}}}, {"uuid": "6ea36083-ee4d-4b49-a387-e7ffb21a84d3", "name": "e38edbdf-acca-456f-9f26-475bd1e7d4ca_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0472938281946713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.40441110210881914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7698473e-55ad-4675-ab96-c68f73e202f5", "name": "f10da870-1a98-4f9d-afa0-1508d9e6ff83", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6ea36083-ee4d-4b49-a387-e7ffb21a84d3"}}}]}, {"uuid": "f5153213-5736-4896-bac5-e95ec3efd810", "name": "load_p1rlv15170_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d2f8fcb-c279-49d5-88be-39e6a1d1990b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7698473e-55ad-4675-ab96-c68f73e202f5"}}}}, {"uuid": "f59209e3-2b75-467b-bf26-981f82c0e69f", "name": "70a64c03-6187-4053-b7cb-e3b2c5bf19e7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.664483224984605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9538644530515166, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "856d1ccc-4a6d-4801-8277-40e6862d50d0", "name": "5f63d5f7-f371-4ccf-9779-492f8bb8b7bc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f59209e3-2b75-467b-bf26-981f82c0e69f"}}}]}, {"uuid": "c2829c3c-272c-4006-ac8d-2617e0370e62", "name": "load_p1rlv15171_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc7cd505-823c-49bb-9e49-3681267dbef0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "856d1ccc-4a6d-4801-8277-40e6862d50d0"}}}}, {"uuid": "d051dd30-ae89-4c67-bd43-6fc4bedd9e0a", "name": "9178c9dd-5219-4698-8f52-aff2f22d2a89_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.664483224984605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9538644530515166, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "122d26a5-f9de-45b9-9ceb-b225d56dc0a6", "name": "f07b5511-be53-44ef-a699-ffefe90618e7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d051dd30-ae89-4c67-bd43-6fc4bedd9e0a"}}}]}, {"uuid": "e9c8b1e2-fa10-41aa-b5e8-0d968a4089c8", "name": "load_p1rlv15171_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc7cd505-823c-49bb-9e49-3681267dbef0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "122d26a5-f9de-45b9-9ceb-b225d56dc0a6"}}}}, {"uuid": "cf9ef428-0e5a-41c0-9c22-c7f3d850f628", "name": "eb19f670-a0bc-4be3-b2a4-fddbb14459d8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.13715702476687, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3795210711832634, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6d52cec0-b460-40fd-81ac-984c9828e283", "name": "5c25944f-08e8-4657-bb47-4a19930fa56b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cf9ef428-0e5a-41c0-9c22-c7f3d850f628"}}}]}, {"uuid": "97641359-1a44-4cd8-bf51-68f7244a794f", "name": "load_p1rlv15180_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e218b01d-f713-4baf-9688-7e77ea413c8c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6d52cec0-b460-40fd-81ac-984c9828e283"}}}}, {"uuid": "0b591a3e-599f-4ac2-ba18-13d14f36399b", "name": "097eb900-2025-4532-bd56-c5e7a836dfd5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.13715702476687, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3795210711832634, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eb3821c5-b7f6-4dc7-a87d-0f997549dd8f", "name": "b2d3304c-0cd9-4650-98f7-ad3323236733", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0b591a3e-599f-4ac2-ba18-13d14f36399b"}}}]}, {"uuid": "80234a72-b646-458d-abc5-b1b670dfbea6", "name": "load_p1rlv15180_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e218b01d-f713-4baf-9688-7e77ea413c8c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eb3821c5-b7f6-4dc7-a87d-0f997549dd8f"}}}}, {"uuid": "ed6adb50-d2ca-49e7-a0af-b3b711ba22b9", "name": "48cad7ff-4b21-496f-9b7e-9111795dc989_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3ad66fff-9252-46e1-b701-234b54d06850", "name": "48cad7ff-4b21-496f-9b7e-9111795dc989_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "489a8e34-f115-4e1f-ba31-2e6c13f264dc", "name": "48cad7ff-4b21-496f-9b7e-9111795dc989_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.96768225252126, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.972384948778122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2222dae9-b9d5-49d4-aa6d-52ccb4e86ffc", "name": "5a1590d8-ac99-4377-8c29-883964d907e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ed6adb50-d2ca-49e7-a0af-b3b711ba22b9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3ad66fff-9252-46e1-b701-234b54d06850"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "489a8e34-f115-4e1f-ba31-2e6c13f264dc"}}}]}, {"uuid": "e5e211ef-445f-464a-84c5-1d7868cc3b32", "name": "load_p1rlv15196", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64634ab5-a5b0-45ae-9763-7d0be029350f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2222dae9-b9d5-49d4-aa6d-52ccb4e86ffc"}}}}, {"uuid": "4f307380-46d3-47c5-bba9-20e079c512ef", "name": "e6b472bb-8ae6-4320-a7b4-b9e96dd4c826_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4727091425662127, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8266013407121705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b8d65bc3-6366-42e6-ac9e-caccf2d56ab6", "name": "d51de9e1-d937-49e5-aae4-012dc576d5af", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4f307380-46d3-47c5-bba9-20e079c512ef"}}}]}, {"uuid": "ddbe7663-6055-4269-bf3f-4f47ab59854f", "name": "load_p1rlv15197_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80a74c6f-c9ec-4742-8fce-ad73c0a6c459"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b8d65bc3-6366-42e6-ac9e-caccf2d56ab6"}}}}, {"uuid": "05ade002-e5e3-4957-983a-7f25931b4b86", "name": "c243d62d-2a4c-4ae1-a4e4-14354d15208b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4727091425662127, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8266013407121705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ca6a98e8-6a77-4566-8bdf-e2588884c9ff", "name": "a28bcc36-e94a-4c0d-9c1d-7c39e9077f4c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "05ade002-e5e3-4957-983a-7f25931b4b86"}}}]}, {"uuid": "774fbd6f-5d4f-41c7-9763-5dd3326edeb4", "name": "load_p1rlv15197_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80a74c6f-c9ec-4742-8fce-ad73c0a6c459"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ca6a98e8-6a77-4566-8bdf-e2588884c9ff"}}}}, {"uuid": "1a64cd3e-a5e7-4c88-a5c9-6a434d68f282", "name": "99fafce9-bcbf-4dbf-b1ea-efde3eec11e6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0052757727111112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4127143879372469, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "53d4034f-4912-4542-8654-099b40e784aa", "name": "c1de5b63-1ec2-43b6-a095-e8a2bd069689", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1a64cd3e-a5e7-4c88-a5c9-6a434d68f282"}}}]}, {"uuid": "14b42caf-a810-40b6-8ce9-ecf6b5736e12", "name": "load_p1rlv15394_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd21ae8b-7841-43b4-871f-316c4b8b4cd2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "53d4034f-4912-4542-8654-099b40e784aa"}}}}, {"uuid": "aaf24261-ff1e-401a-8dc7-a40cd8c20954", "name": "fde98af1-a25f-4925-abb1-965c61a64a24_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0052757727111112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4127143879372469, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "93905f3d-11ae-48b8-a283-dbb7b338bb5e", "name": "b1a83f36-c226-4a2c-a50f-aff46bc2b790", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aaf24261-ff1e-401a-8dc7-a40cd8c20954"}}}]}, {"uuid": "128c9748-eb61-41b0-982c-2c4247dfc49e", "name": "load_p1rlv15394_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd21ae8b-7841-43b4-871f-316c4b8b4cd2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "93905f3d-11ae-48b8-a283-dbb7b338bb5e"}}}}, {"uuid": "992cfd71-f12f-4830-9dec-091fa7812f7d", "name": "7f690059-902d-4fb4-a079-c3235de18eb5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2767849318619047, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.48605417385422345, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "442d77e5-1dca-4571-a3e5-ac4e43a550ed", "name": "1f87872c-f748-4725-a7ea-bceb11b82b15", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "992cfd71-f12f-4830-9dec-091fa7812f7d"}}}]}, {"uuid": "934e91ae-163b-4971-abd3-a22c61cc0d93", "name": "load_p1rlv15399_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ec1f313-f341-498c-b1c2-6669b1cbc629"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "442d77e5-1dca-4571-a3e5-ac4e43a550ed"}}}}, {"uuid": "9248525f-1675-4fc4-9811-af7fd9d4f41c", "name": "3e590369-cf2f-4e43-9c1e-24d74b8f9b9f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2767849318619047, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.48605417385422345, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0b2184b1-a104-41e6-9370-e2099151cc50", "name": "9a3c549e-db8d-45ca-b44e-ec1e12111b3c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9248525f-1675-4fc4-9811-af7fd9d4f41c"}}}]}, {"uuid": "191ea403-3045-4b32-a91f-e399b4afbde0", "name": "load_p1rlv15399_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ec1f313-f341-498c-b1c2-6669b1cbc629"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0b2184b1-a104-41e6-9370-e2099151cc50"}}}}, {"uuid": "f63f659e-6f78-4805-890a-ab555465155b", "name": "0f710b31-0344-4368-9937-9c8df3e60cde_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.962031206451152, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.4366749645571537, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5c0485ab-103f-4e09-adac-9ea1fd468772", "name": "2f07204f-afcd-4e4f-a142-362e75288834", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f63f659e-6f78-4805-890a-ab555465155b"}}}]}, {"uuid": "c089d7eb-49d0-4147-a56e-a1d180a82959", "name": "load_p1rlv15418_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9ca373a-b1c3-464d-bbe3-c05b728beb30"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5c0485ab-103f-4e09-adac-9ea1fd468772"}}}}, {"uuid": "7acbdd19-a91c-419d-b26e-0dfa678951c5", "name": "1095f810-19fd-4e77-acf7-75afaf7eda5e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.962031206451152, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.4366749645571537, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "441f6f39-d3fa-4365-a20e-46ad21d3c6e2", "name": "2e040e4d-bf95-4452-b67f-8367ad8815a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7acbdd19-a91c-419d-b26e-0dfa678951c5"}}}]}, {"uuid": "c713637f-bc7f-4b41-9a3a-30c148f5104e", "name": "load_p1rlv15418_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9ca373a-b1c3-464d-bbe3-c05b728beb30"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "441f6f39-d3fa-4365-a20e-46ad21d3c6e2"}}}}, {"uuid": "d3a9d3fd-1a34-44e4-8200-eee0a284acb4", "name": "b74939b1-fd6e-4f11-8c62-f7dc92cabb82_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.365256087534968, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9406994095530364, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2373d602-d50f-45db-9d74-e71e15007f0e", "name": "2292044b-f6fb-4e61-9d67-9be2743fc8fc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d3a9d3fd-1a34-44e4-8200-eee0a284acb4"}}}]}, {"uuid": "20a84130-1e07-46c3-a786-3c298f7ca770", "name": "load_p1rlv15419_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8bc46399-0276-4ae7-aa8b-4cdd3d3555e8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2373d602-d50f-45db-9d74-e71e15007f0e"}}}}, {"uuid": "f27afbe4-10a3-4ac5-ade2-6bbdd2efb2b0", "name": "cfbae373-28f1-4fdc-ba91-f768f9d0da3f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.365256087534968, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9406994095530364, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ae825d0a-d7ce-4115-ae2e-a1da6ac61fc6", "name": "eded9cdc-5c13-460c-9134-1d7e65e17b67", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f27afbe4-10a3-4ac5-ade2-6bbdd2efb2b0"}}}]}, {"uuid": "be3c7974-aaf8-4b57-9b76-b60866b6f18b", "name": "load_p1rlv15419_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8bc46399-0276-4ae7-aa8b-4cdd3d3555e8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ae825d0a-d7ce-4115-ae2e-a1da6ac61fc6"}}}}, {"uuid": "16476ff1-9623-445d-bc5e-aaa6a2b810a5", "name": "7194d1ad-2e55-4e2b-b643-bb700216f4cb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e1d8e8c1-34c8-4b1c-b9e1-b84b5bbb3cfc", "name": "3a932951-92ce-4fbc-85c0-2c5bcdd3ef0e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "16476ff1-9623-445d-bc5e-aaa6a2b810a5"}}}]}, {"uuid": "ac52531c-a55e-4bf0-b5d2-4d084bb9e315", "name": "load_p1rlv15423_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26009a7e-9bfc-4967-af28-4d8937539eb1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e1d8e8c1-34c8-4b1c-b9e1-b84b5bbb3cfc"}}}}, {"uuid": "c486cd31-8e17-47ee-961e-aec42080087a", "name": "ea850e56-120c-4fac-a9cc-4cddaf1d3bb5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "44f1561b-29cb-47ea-a612-238ac8057242", "name": "187a98ff-7ce4-48b4-a14c-4c538f2bd4eb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c486cd31-8e17-47ee-961e-aec42080087a"}}}]}, {"uuid": "e4273425-20a2-41e6-954c-5ab2df4e2a7a", "name": "load_p1rlv15423_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26009a7e-9bfc-4967-af28-4d8937539eb1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "44f1561b-29cb-47ea-a612-238ac8057242"}}}}, {"uuid": "dbcddb3b-e55f-4b76-9fcf-1d9114e1a182", "name": "f9f528d9-9744-4621-bbec-785f15cc7011_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7411160800233395, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1601349573814363, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "233a1839-ef2e-4e0a-8020-9cb19c9c05ea", "name": "59c9eeb9-e4a9-4356-953a-d0ec6c056115", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dbcddb3b-e55f-4b76-9fcf-1d9114e1a182"}}}]}, {"uuid": "5fc4312b-569e-4e54-b8d5-a8c5e7e0f957", "name": "load_p1rlv15466_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "544be417-0db6-45a7-8314-ec40944781fa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "233a1839-ef2e-4e0a-8020-9cb19c9c05ea"}}}}, {"uuid": "9611ddc9-264a-4100-afb5-47f14ffa366d", "name": "8eb7a877-fc86-45d3-ad46-dff8762e76c8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7411160800233395, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1601349573814363, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "49e70e43-82bf-4626-a209-25e0c3b241f4", "name": "c5532ae5-59cd-4da1-8f85-47d57292a6ea", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9611ddc9-264a-4100-afb5-47f14ffa366d"}}}]}, {"uuid": "bd4cd469-9871-4f86-aa59-8c4c8eeb4afe", "name": "load_p1rlv15466_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "544be417-0db6-45a7-8314-ec40944781fa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "49e70e43-82bf-4626-a209-25e0c3b241f4"}}}}, {"uuid": "9ddeff1c-1865-47b5-9a20-6f4480f52a6a", "name": "74631308-8cae-47cc-9953-c2d80336a11f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7411160800233395, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1601349573814363, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c2945fa0-ff8a-4d7f-8392-1840ea3e35d1", "name": "0c493fbc-aa14-4ae8-951e-aa0d4692833d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9ddeff1c-1865-47b5-9a20-6f4480f52a6a"}}}]}, {"uuid": "1ada6dce-48f3-4868-a6f9-c9413cb6bba8", "name": "load_p1rlv15474_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34e0ffc2-da17-441b-bd4d-26d5a1104712"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c2945fa0-ff8a-4d7f-8392-1840ea3e35d1"}}}}, {"uuid": "0f3eb859-0b60-4406-bf90-21daf8463516", "name": "cb2f7f14-4b4f-4142-ab3d-d86c1f877024_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7411160800233395, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1601349573814363, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5a9977ae-9a9b-4938-9b27-cc4a50d6a106", "name": "d7c4b4ea-d122-4f14-86d5-d8b00795d057", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0f3eb859-0b60-4406-bf90-21daf8463516"}}}]}, {"uuid": "4d230c80-1c74-4403-ac4b-a51751d36efe", "name": "load_p1rlv15474_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34e0ffc2-da17-441b-bd4d-26d5a1104712"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5a9977ae-9a9b-4938-9b27-cc4a50d6a106"}}}}, {"uuid": "bde46da1-4eb0-4327-a607-f4125b62957e", "name": "b4ab7e8c-1e80-4c6d-8097-271037e152d5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.84153235443771, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.447226409705929, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c721f5cd-7665-48e9-822b-b643ca760c4c", "name": "b1002f59-669b-4a7a-b223-b0ce571d42ed", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bde46da1-4eb0-4327-a607-f4125b62957e"}}}]}, {"uuid": "a6d4f5dd-727d-412a-acf1-c047ac85db94", "name": "load_p1rlv15478_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "335df4da-50d2-4fbe-a271-ac04257d35c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c721f5cd-7665-48e9-822b-b643ca760c4c"}}}}, {"uuid": "7b1ce745-357c-4b01-aa87-985d6a6d93ef", "name": "130d584d-ee27-4cf0-b7f9-a354626a372c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.84153235443771, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.447226409705929, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cecd57ee-2d04-4090-8ab6-96fb8a32602c", "name": "d1c5099b-ce74-4f1a-beee-013966dd559c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b1ce745-357c-4b01-aa87-985d6a6d93ef"}}}]}, {"uuid": "5610562d-4d19-4e4b-96d9-2e6f54c7a8d1", "name": "load_p1rlv15478_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "335df4da-50d2-4fbe-a271-ac04257d35c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cecd57ee-2d04-4090-8ab6-96fb8a32602c"}}}}, {"uuid": "10d4058c-cc51-4884-8918-3eabe6c30d8f", "name": "5c33781b-3404-4773-8418-6f4559d102a7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6639c955-f5ea-4a95-8885-340171b23e94", "name": "bc182204-578a-4009-9d2a-53d116b4eb8a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "10d4058c-cc51-4884-8918-3eabe6c30d8f"}}}]}, {"uuid": "339cf270-76e3-42a4-8e2a-30f9527fc3cf", "name": "load_p1rlv15483_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c4e3eac-0b1a-4feb-b39f-079c6d2c1d82"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6639c955-f5ea-4a95-8885-340171b23e94"}}}}, {"uuid": "02eec10f-baad-4d72-8fd2-adfd32006494", "name": "232ddfb9-0f86-4bb7-9e22-c382d8cbeca8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "270f4f58-9952-408d-8edf-87be15ede35d", "name": "24482191-182f-4110-8be8-9af3853180fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "02eec10f-baad-4d72-8fd2-adfd32006494"}}}]}, {"uuid": "5c1376af-a293-4081-a620-91d404fa10f0", "name": "load_p1rlv15483_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c4e3eac-0b1a-4feb-b39f-079c6d2c1d82"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "270f4f58-9952-408d-8edf-87be15ede35d"}}}}, {"uuid": "4d9460f9-f8ea-45a4-a8d8-d4823488d408", "name": "f20cdf6d-fab2-4571-a162-b620ee122f03_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "45439d97-58ce-42f2-bec5-c7b74da13429", "name": "25743876-2804-4dfe-96a3-9e9f6cfed976", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4d9460f9-f8ea-45a4-a8d8-d4823488d408"}}}]}, {"uuid": "5fa72b88-1b29-4b26-a54d-c967ea3e6cd2", "name": "load_p1rlv15484_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6749066f-4739-41ec-8369-8da49dd9e1c8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "45439d97-58ce-42f2-bec5-c7b74da13429"}}}}, {"uuid": "94c50990-e8f0-40b8-a2de-e85f1cdc0cb3", "name": "8257838d-9cc7-4b87-99c8-b8116910d4d4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6ae8cefd-e967-4b54-a346-a5c769ef7a4a", "name": "f817426f-5b7e-4fbc-93b5-7a4f97bf6835", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "94c50990-e8f0-40b8-a2de-e85f1cdc0cb3"}}}]}, {"uuid": "3801303e-0611-4e7b-b70a-2ae965aa8ee3", "name": "load_p1rlv15484_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6749066f-4739-41ec-8369-8da49dd9e1c8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6ae8cefd-e967-4b54-a346-a5c769ef7a4a"}}}}, {"uuid": "2a510bae-755d-43de-b23b-ab8993ce13df", "name": "a8d69f35-1632-45b7-8cd5-541ffa86e572_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5041010955030301, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21577690333785765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "14f155fe-c1f1-44d3-99b0-b99ce0157e64", "name": "8b9a313a-c161-41b2-9dc5-5decb4da3eca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2a510bae-755d-43de-b23b-ab8993ce13df"}}}]}, {"uuid": "6fb69007-5eb9-4a48-9d3b-b7e35932f1b2", "name": "load_p1rlv15487_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "921f8f54-ff83-4d2f-8bf4-ee80bab64ce8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "14f155fe-c1f1-44d3-99b0-b99ce0157e64"}}}}, {"uuid": "bb7f3243-53f3-4af8-901c-e5b6688d9085", "name": "f413b114-08d9-4268-9af4-1a112227dab0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5041010955030301, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21577690333785765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "09e7c2bd-e5e6-47a5-89ee-c10bc7fa7efd", "name": "8d2c276d-6085-4e57-9f7e-cad935bc1bae", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bb7f3243-53f3-4af8-901c-e5b6688d9085"}}}]}, {"uuid": "2f9dfbab-cc48-4d6e-a657-2522ba676563", "name": "load_p1rlv15487_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "921f8f54-ff83-4d2f-8bf4-ee80bab64ce8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "09e7c2bd-e5e6-47a5-89ee-c10bc7fa7efd"}}}}, {"uuid": "4c5a3559-3711-4630-a2cb-1f593c502807", "name": "b30379a4-c9c8-4d1e-a238-a2c504c90b8b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7909002853206712, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1704468602852825, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a291a66b-7b02-4c1e-88d4-80d6f3907695", "name": "10fd141f-c5e0-4494-a3d7-1509990cdf8d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4c5a3559-3711-4630-a2cb-1f593c502807"}}}]}, {"uuid": "e4e71f45-134a-4075-b697-9d222843e30d", "name": "load_p1rlv15488_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6579cc93-2b08-4010-816d-3bef509000cd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a291a66b-7b02-4c1e-88d4-80d6f3907695"}}}}, {"uuid": "3d218d4b-6589-4683-9d50-4f072cf955f9", "name": "a46442de-50e9-4cb2-8bd5-76f12638c054_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7909002853206712, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1704468602852825, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "273f8495-5041-4d50-be86-c5df21cf1202", "name": "e814b988-a237-4f36-a2e0-9eca92db73a3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3d218d4b-6589-4683-9d50-4f072cf955f9"}}}]}, {"uuid": "8ad3ab49-7155-403f-8f7a-db1c665052f7", "name": "load_p1rlv15488_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6579cc93-2b08-4010-816d-3bef509000cd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "273f8495-5041-4d50-be86-c5df21cf1202"}}}}, {"uuid": "9ddaceec-25b1-4e2f-97fe-e0f3bda9eab1", "name": "45abe17e-911f-4a38-90ef-29bf9a2995e1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4163439957648214, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5697938312046736, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f807423-4bcf-462f-9765-e7afcb199c02", "name": "9d8d17ff-60b3-450b-9fa9-181929912aa2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9ddaceec-25b1-4e2f-97fe-e0f3bda9eab1"}}}]}, {"uuid": "b693eeb6-80f6-474f-a21a-04fd615fc669", "name": "load_p1rlv15523_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37ccfa64-1373-49b2-85f6-279abea3c945"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f807423-4bcf-462f-9765-e7afcb199c02"}}}}, {"uuid": "b680a583-c323-4b66-8846-9e0cb1692ee2", "name": "241c0c4f-891a-4ae2-8bd9-8f4b17b2df31_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4163439957648214, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5697938312046736, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "88ae3fc4-dee9-4abb-b7cd-9f1c0c9a2e73", "name": "6b3d4b15-8bbc-4566-bfcc-58aef5610e62", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b680a583-c323-4b66-8846-9e0cb1692ee2"}}}]}, {"uuid": "5ab1fe3e-972c-4829-a87c-bab6ec203b43", "name": "load_p1rlv15523_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37ccfa64-1373-49b2-85f6-279abea3c945"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "88ae3fc4-dee9-4abb-b7cd-9f1c0c9a2e73"}}}}, {"uuid": "bcff2667-a612-43db-b611-5390a5c76156", "name": "896c245a-fddc-4280-b962-53dc8c8b7a65_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2037641724563426, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8275766375494601, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "64635c39-be3f-42a4-b66f-6e623db59e30", "name": "1b4a8ece-7618-47d6-a6ca-d72ab84ae452", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bcff2667-a612-43db-b611-5390a5c76156"}}}]}, {"uuid": "7a60fee1-177c-4473-bb96-ec8044cd167e", "name": "load_p1rlv15525_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6eec860d-08cf-4690-93e6-d909429d363d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "64635c39-be3f-42a4-b66f-6e623db59e30"}}}}, {"uuid": "a56079a2-f22d-4a10-9c2b-2a5a03e028d1", "name": "3353557b-0762-4889-a95f-cbbe120e2d22_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2037641724563426, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8275766375494601, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f5c77b29-b8ef-416b-bd23-ded5d646be5d", "name": "c72c9697-395f-4e8e-8c22-f88adb1c4dbc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a56079a2-f22d-4a10-9c2b-2a5a03e028d1"}}}]}, {"uuid": "ea9b4f68-5e35-439b-a1a2-820e07a5e96b", "name": "load_p1rlv15525_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6eec860d-08cf-4690-93e6-d909429d363d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f5c77b29-b8ef-416b-bd23-ded5d646be5d"}}}}, {"uuid": "f4cd6ac1-0942-444e-a0a8-7c10cdce52b3", "name": "280a77ec-ddcc-443d-993b-a39b278f4390_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.679689620441751, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9077324041357607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "80f4e690-25c1-4a86-87f6-54781fcab371", "name": "b0b7c20a-83e7-4f0c-8716-e548fb66a9f5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f4cd6ac1-0942-444e-a0a8-7c10cdce52b3"}}}]}, {"uuid": "91886b57-b270-4644-aaee-be8a5767e737", "name": "load_p1rlv15542_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b09822b3-a220-48ff-ad4f-62fca602f8b6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "80f4e690-25c1-4a86-87f6-54781fcab371"}}}}, {"uuid": "602a35b7-dba3-42fb-8c10-66468760c864", "name": "ffe9df7b-cc38-4e0f-b2c5-46dff8650db3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.679689620441751, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9077324041357607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c0697a93-163a-4601-81ad-de35e394789c", "name": "455cb216-13e7-48e4-aba4-19da4d9e19cf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "602a35b7-dba3-42fb-8c10-66468760c864"}}}]}, {"uuid": "50d02109-4fa7-425c-b1ec-cf5ea46ed546", "name": "load_p1rlv15542_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b09822b3-a220-48ff-ad4f-62fca602f8b6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c0697a93-163a-4601-81ad-de35e394789c"}}}}, {"uuid": "b5b2ec6f-7406-4e8c-8117-e3743b7aab68", "name": "e5ce500f-b8f4-4f7b-ba76-4a77731bf6f3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7539305984890898, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4187015133753737, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bfce76b1-d370-4fd8-a7f4-a3a9b2e2ce59", "name": "8934b0b2-50fc-4d11-bcbf-0a7501b30eea", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5b2ec6f-7406-4e8c-8117-e3743b7aab68"}}}]}, {"uuid": "e9e2fd04-1682-4241-8f34-246164c32690", "name": "load_p1rlv15603_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "688da57a-6f10-4ef8-8763-202a88c3a495"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bfce76b1-d370-4fd8-a7f4-a3a9b2e2ce59"}}}}, {"uuid": "42e70254-ef9d-47f3-9073-ef5f07401849", "name": "893cabcb-4969-4b8d-910c-775e1f80c569_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7539305984890898, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4187015133753737, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9d85ee74-4d56-475d-8d7d-6a212fd7253b", "name": "e3947cd9-083b-421a-8219-af7133a189fd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "42e70254-ef9d-47f3-9073-ef5f07401849"}}}]}, {"uuid": "67f7ca6b-7c11-434c-8855-4784b10b10f6", "name": "load_p1rlv15603_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "688da57a-6f10-4ef8-8763-202a88c3a495"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9d85ee74-4d56-475d-8d7d-6a212fd7253b"}}}}, {"uuid": "6ffcd115-2598-4bac-bcfc-fb62b8aa15e3", "name": "ad64bf0d-2411-4167-9270-bbf569eec871_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.69722938823788, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6546008506549251, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5bd3bed4-f868-4755-a420-30d0862d64e3", "name": "4be4563f-baab-4b66-a639-dae8729f5310", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6ffcd115-2598-4bac-bcfc-fb62b8aa15e3"}}}]}, {"uuid": "ba1acbf2-320f-4439-a3a9-058703243ea8", "name": "load_p1rlv15606_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c32ce070-e690-4fc1-92ac-f857691de578"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5bd3bed4-f868-4755-a420-30d0862d64e3"}}}}, {"uuid": "f0b37315-8176-4bcd-9b23-2b6f1208dd34", "name": "5ea4e10e-9355-47fc-aefc-ca29575c354e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.69722938823788, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6546008506549251, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e5cbc980-da5d-4976-8239-da70f4814fb8", "name": "38104937-5235-4578-9a80-ed28ecf1f1e0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f0b37315-8176-4bcd-9b23-2b6f1208dd34"}}}]}, {"uuid": "d314859a-4fed-404b-9eb0-4c1bf2504af3", "name": "load_p1rlv15606_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c32ce070-e690-4fc1-92ac-f857691de578"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e5cbc980-da5d-4976-8239-da70f4814fb8"}}}}, {"uuid": "000d3dc0-f13e-4cd1-8023-a518239f75cc", "name": "3e28fefb-5c4e-4f45-9665-959cfbf8e030_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6722127407962883, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033140171384262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "487b316a-6eae-46d8-8da4-a49b958aa033", "name": "41e083f6-fd8b-4d8c-a88c-fbf39b16359a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "000d3dc0-f13e-4cd1-8023-a518239f75cc"}}}]}, {"uuid": "99ab83ce-9bfe-4afe-9493-096f255b300d", "name": "load_p1rlv15607_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32291502-d7be-4b45-8af7-cb217448e73f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "487b316a-6eae-46d8-8da4-a49b958aa033"}}}}, {"uuid": "d0ce0434-a2e1-43af-9811-5850e3713675", "name": "0927996e-7a89-435c-8ac2-9da5f99cdc6f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6722127407962883, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033140171384262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6275d4d4-c7e3-479c-ade6-ca9995459a49", "name": "a78fce1b-9591-4a78-a53e-fef3558fa051", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d0ce0434-a2e1-43af-9811-5850e3713675"}}}]}, {"uuid": "ed46658d-25fa-4de9-93a1-c07bf5b43be0", "name": "load_p1rlv15607_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32291502-d7be-4b45-8af7-cb217448e73f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6275d4d4-c7e3-479c-ade6-ca9995459a49"}}}}, {"uuid": "37e6eb60-0fee-4f18-8a8a-691d4dd6f260", "name": "b17a6cc9-d01c-400d-b251-544ea778886f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.054093584716578, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9114545444360403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8d6d7a31-22b3-4faf-8a02-d37e283c22cb", "name": "6e65c48a-a827-4617-88b1-a1772b15461b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "37e6eb60-0fee-4f18-8a8a-691d4dd6f260"}}}]}, {"uuid": "02ec340a-8c87-4c2b-955e-5aae9a00fb2e", "name": "load_p1rlv15614_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ab2d6dc-f5bb-4320-86f3-bf08bb7cf93f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8d6d7a31-22b3-4faf-8a02-d37e283c22cb"}}}}, {"uuid": "3efb4f1c-9dca-4aa3-87db-2a1037365171", "name": "91fa5bca-4df5-4bf9-a30a-46da7bf654db_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.054093584716578, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9114545444360403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "702de970-2fb2-42de-a18b-eaa10e04da4d", "name": "339375d0-a740-4ced-85a1-ea41a96bd866", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3efb4f1c-9dca-4aa3-87db-2a1037365171"}}}]}, {"uuid": "38b862f2-5180-4529-8e6d-63b195d21ccd", "name": "load_p1rlv15614_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ab2d6dc-f5bb-4320-86f3-bf08bb7cf93f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "702de970-2fb2-42de-a18b-eaa10e04da4d"}}}}, {"uuid": "4ed6d4fa-482b-4e4c-a3af-9717ec5571f1", "name": "04a9c41e-514e-46d8-a981-f56c82f86ab6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0288569450045768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2608148575838028, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "760078dd-1eb6-403e-ae47-5fcb613d909f", "name": "90450a01-a2f4-4bdf-bddf-cf971963920d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4ed6d4fa-482b-4e4c-a3af-9717ec5571f1"}}}]}, {"uuid": "363d5f05-c5c1-45fb-8ad1-72cfdc49b352", "name": "load_p1rlv15617_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6106bbe7-7a47-4c50-8b2a-d46d7432bccf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "760078dd-1eb6-403e-ae47-5fcb613d909f"}}}}, {"uuid": "337b3c0a-48de-4e1f-abb0-f7113dfa905c", "name": "f5a3bfb4-2f3c-4665-8f9e-37812e09fe7d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0288569450045768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2608148575838028, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4af8db5e-535a-4b92-b15a-94b672e51c83", "name": "c364696d-a746-482f-a694-2077f40a5a0a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "337b3c0a-48de-4e1f-abb0-f7113dfa905c"}}}]}, {"uuid": "746f94ee-b1ee-4d67-9ea8-0137b0dd340f", "name": "load_p1rlv15617_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6106bbe7-7a47-4c50-8b2a-d46d7432bccf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4af8db5e-535a-4b92-b15a-94b672e51c83"}}}}, {"uuid": "118b10ed-dfde-40ac-bce5-9b60a224ee16", "name": "c423dd2c-9fdf-45de-a9ca-ae80ac1330ca_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3483029031483318, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6505451661884267, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c096a36-d6ee-4d43-8f51-db90300a191b", "name": "17e66d5e-3d71-4238-ad31-0c9e1bd1cea6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "118b10ed-dfde-40ac-bce5-9b60a224ee16"}}}]}, {"uuid": "9b240a29-afa4-4865-8113-dce61285e40a", "name": "load_p1rlv15622_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1151b559-3ae0-4863-9363-9b395bbfc403"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c096a36-d6ee-4d43-8f51-db90300a191b"}}}}, {"uuid": "2b7add0b-c3d1-4d2e-a2a9-20a31032ceaf", "name": "221e5460-385d-4650-90cb-ba64d3817077_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3483029031483318, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6505451661884267, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9f4c6cc9-7df8-41ef-b43b-9b6fa5d9299d", "name": "3a46e619-76b4-44c1-b1e1-10acbd222b4d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2b7add0b-c3d1-4d2e-a2a9-20a31032ceaf"}}}]}, {"uuid": "960c7b61-0dcc-4347-ad5f-706dd7dd4230", "name": "load_p1rlv15622_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1151b559-3ae0-4863-9363-9b395bbfc403"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9f4c6cc9-7df8-41ef-b43b-9b6fa5d9299d"}}}}, {"uuid": "4e34e414-770f-4d2a-8a5b-2541c00f2c38", "name": "4fda3b3e-5dfa-4b73-8a3d-f338684f3ebe_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 12.451565419664076, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.11178199687988, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e87b6646-27e9-40f3-b312-4ae56d20f783", "name": "4fda3b3e-5dfa-4b73-8a3d-f338684f3ebe_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 12.451565419664076, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.11178199687988, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "544c217e-5f15-498a-9750-46173095f189", "name": "4fda3b3e-5dfa-4b73-8a3d-f338684f3ebe_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 12.451565419664076, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.11178199687988, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5619dbe0-729d-496b-a53c-dfa9b5098b3d", "name": "6cd198bd-eba6-4100-9ef6-fd07bee7d54e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4e34e414-770f-4d2a-8a5b-2541c00f2c38"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e87b6646-27e9-40f3-b312-4ae56d20f783"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "544c217e-5f15-498a-9750-46173095f189"}}}]}, {"uuid": "81a3d98f-432e-40e7-9b4c-5838469bd7f6", "name": "load_p1rlv15628", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13eabcb1-332a-4c7a-8042-214ada721424"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5619dbe0-729d-496b-a53c-dfa9b5098b3d"}}}}, {"uuid": "0d0d1323-1ea5-4f85-b268-c6c09adbb522", "name": "8d1d965a-01d1-4b25-85ba-b67975992f72_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0240502132333855, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5295456567023789, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fc8b04d3-ff3a-4865-8fde-5b1bd3b1a8ad", "name": "9b6b6641-24b2-4219-9311-1328277c753a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0d0d1323-1ea5-4f85-b268-c6c09adbb522"}}}]}, {"uuid": "d3b8c2d1-689b-453e-91e9-7b2d36b89d4d", "name": "load_p1rlv15629_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec0bca53-a58b-4004-8dba-8defca9db4c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fc8b04d3-ff3a-4865-8fde-5b1bd3b1a8ad"}}}}, {"uuid": "8fd15230-b131-4c8c-8c58-3f1431ff2688", "name": "c3d46240-f821-4126-bc47-1abfa5d04a49_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0240502132333855, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5295456567023789, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "584328b2-9bf0-49d5-ba52-666575ee7fe6", "name": "e9380927-a696-4fef-ad69-eb89d8704985", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8fd15230-b131-4c8c-8c58-3f1431ff2688"}}}]}, {"uuid": "0ce4f795-f79d-4360-9d3d-c469cefe50ef", "name": "load_p1rlv15629_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec0bca53-a58b-4004-8dba-8defca9db4c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "584328b2-9bf0-49d5-ba52-666575ee7fe6"}}}}, {"uuid": "07faca36-6635-455b-bb11-e5d33dc5fb41", "name": "7a86b912-7590-4f5c-8842-22c89ee1209f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.459276697523187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8425022918187992, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f26f51b1-e972-4612-b052-a598f9da1ed2", "name": "ce8fc209-c9b3-4f81-8c4c-b966dc154461", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "07faca36-6635-455b-bb11-e5d33dc5fb41"}}}]}, {"uuid": "3c23a9e5-e695-4862-a1ed-1b7013922081", "name": "load_p1rlv15634_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5af6dae-d20f-4a31-9544-b9455cd639bd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f26f51b1-e972-4612-b052-a598f9da1ed2"}}}}, {"uuid": "062c5c69-88c0-4ff2-ad09-c6b4f4e6e5c7", "name": "e977cde3-24e0-48e7-952e-4cd42a95a60b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.459276697523187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8425022918187992, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "29e202bb-523d-4a00-92c4-a61cf33b8014", "name": "a8451a90-b696-43d8-9d36-15a3a6a6e378", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "062c5c69-88c0-4ff2-ad09-c6b4f4e6e5c7"}}}]}, {"uuid": "2bec8ef3-d1d1-4375-b3ad-4fcd521998da", "name": "load_p1rlv15634_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5af6dae-d20f-4a31-9544-b9455cd639bd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "29e202bb-523d-4a00-92c4-a61cf33b8014"}}}}, {"uuid": "f4c2e805-198e-4d18-93b9-2bef44ea8c3a", "name": "df77f211-3a0a-498a-89e3-b082fc8ee120_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6524083002915736, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21201745820683848, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "157134c6-e79c-411e-91d9-9ea70e645daa", "name": "57a7b7d3-f679-41f1-9db7-41157808fb4f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f4c2e805-198e-4d18-93b9-2bef44ea8c3a"}}}]}, {"uuid": "48fe9c33-79f4-47bd-9ba3-6a4d2b94dcef", "name": "load_p1rlv15638_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2715a637-d6f0-4e7b-b43e-20836bf4e614"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "157134c6-e79c-411e-91d9-9ea70e645daa"}}}}, {"uuid": "d17d3786-2de1-4665-8df1-993edcc55061", "name": "2ac54f16-2236-410d-99e9-770bb50b4cd1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6524083002915736, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21201745820683848, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "973e1374-c51c-4bbb-b95f-6b9283457b45", "name": "a7af89c0-c088-456c-baf2-7af4041c5da8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d17d3786-2de1-4665-8df1-993edcc55061"}}}]}, {"uuid": "4b180f70-5021-40fe-a7f3-6558f7c9cbd0", "name": "load_p1rlv15638_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2715a637-d6f0-4e7b-b43e-20836bf4e614"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "973e1374-c51c-4bbb-b95f-6b9283457b45"}}}}, {"uuid": "34ae07d1-4965-456f-83b7-f0911007dd8b", "name": "ee1d6b15-d1a0-4357-b0bd-3694826cf032_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1219512592986662, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8685822493081499, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "609d6800-53ba-4091-b201-c639a89f9b22", "name": "14b4f633-e879-4cc6-a1e6-73404bf779da", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "34ae07d1-4965-456f-83b7-f0911007dd8b"}}}]}, {"uuid": "8a26e622-7b55-4e5d-a0c0-c74de1ab2a4d", "name": "load_p1rlv15645_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "449098c3-4f65-4350-863f-4b7bc1f14493"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "609d6800-53ba-4091-b201-c639a89f9b22"}}}}, {"uuid": "6705cba9-52b3-44f6-be0d-5b207c79af4e", "name": "b14e774b-701d-4159-be78-c4cb209404a7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1219512592986662, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8685822493081499, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "292da20d-3df1-41dd-bedc-52931193eedc", "name": "e58612bc-30a2-4e29-b570-95ec6244c410", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6705cba9-52b3-44f6-be0d-5b207c79af4e"}}}]}, {"uuid": "b156a757-1c66-49db-9928-f98fc3643bce", "name": "load_p1rlv15645_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "449098c3-4f65-4350-863f-4b7bc1f14493"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "292da20d-3df1-41dd-bedc-52931193eedc"}}}}, {"uuid": "d3bc3cbe-2ba2-483c-9915-bcb5ce6828ef", "name": "9a5d157c-5747-4591-9475-03cad3a8c47e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.567401274738218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6497123013243786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "343e3115-3ac2-45ff-bdd7-ba9f1eeef288", "name": "137085b1-cbcb-4fee-a841-5b1852556baa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d3bc3cbe-2ba2-483c-9915-bcb5ce6828ef"}}}]}, {"uuid": "c7d94431-5e19-498e-820d-04507086783f", "name": "load_p1rlv16114_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5984e209-9f0e-4844-91e6-902c8329f13c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "343e3115-3ac2-45ff-bdd7-ba9f1eeef288"}}}}, {"uuid": "563d990f-0a48-4bd7-b6be-72ff20388a91", "name": "711144a8-1d7f-4d35-a0a6-e068c2cad6a0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.567401274738218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6497123013243786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "905c6c36-2f29-4f53-9434-9f23eac4da33", "name": "7231060f-4920-43b1-8d1f-19720e20748a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "563d990f-0a48-4bd7-b6be-72ff20388a91"}}}]}, {"uuid": "2d1287d2-7d33-4437-b0d3-ec9948e8b482", "name": "load_p1rlv16114_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5984e209-9f0e-4844-91e6-902c8329f13c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "905c6c36-2f29-4f53-9434-9f23eac4da33"}}}}, {"uuid": "4aadcbeb-c078-40bf-85e3-dc67375c909d", "name": "13cd89b5-b77c-4a31-9214-e520fd74f0ab_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7463758536661063, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1812611818115355, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "13578549-07e9-4bbe-ae2d-0e6934e18e02", "name": "44ce35c9-dc72-4262-bf60-5f311fe0d931", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4aadcbeb-c078-40bf-85e3-dc67375c909d"}}}]}, {"uuid": "271b69d3-beeb-4543-b1cf-1f1820fc4db1", "name": "load_p1rlv16115_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52d1b79d-5c6b-4b44-9998-600c6debd999"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "13578549-07e9-4bbe-ae2d-0e6934e18e02"}}}}, {"uuid": "7d7debbd-e8f9-4216-b4e4-0ae296e425e7", "name": "443a895b-503d-424b-a6d4-48b372820048_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7463758536661063, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1812611818115355, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "20226c39-1722-4a0b-8de8-c3711613ea03", "name": "f44b6716-a448-474e-b9ec-2dd11690db6e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7d7debbd-e8f9-4216-b4e4-0ae296e425e7"}}}]}, {"uuid": "96585543-3d95-45a8-bdc5-a5c1a3ec6ad6", "name": "load_p1rlv16115_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52d1b79d-5c6b-4b44-9998-600c6debd999"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "20226c39-1722-4a0b-8de8-c3711613ea03"}}}}, {"uuid": "7eaaac68-1b01-4f3f-8872-e0a5be83a3b3", "name": "d8d7bb65-b83f-4950-84a4-763f72a4230a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.915650640127065, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8660189470929796, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aefbedba-7672-4b17-9874-24e2cd6fb05a", "name": "55329a86-bb37-49ad-8576-42ccfd21db71", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7eaaac68-1b01-4f3f-8872-e0a5be83a3b3"}}}]}, {"uuid": "88bb12b4-c9e0-438a-9efc-f9ffaeb42d1d", "name": "load_p1rlv16116_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "972f8088-b67b-47d0-a86f-49179dfb1c92"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aefbedba-7672-4b17-9874-24e2cd6fb05a"}}}}, {"uuid": "04857d11-51c4-4ba0-ace8-5adbbacb71ea", "name": "b2e208d9-3790-47b8-b509-ceac371b0cbd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.915650640127065, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8660189470929796, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3098cd40-5dd6-4996-b1bc-fc3eb5f29afe", "name": "7060432c-11ff-45fc-bb69-17cfbbdfb27c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "04857d11-51c4-4ba0-ace8-5adbbacb71ea"}}}]}, {"uuid": "20214244-ec78-4484-b061-527c9dcfdbd9", "name": "load_p1rlv16116_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "972f8088-b67b-47d0-a86f-49179dfb1c92"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3098cd40-5dd6-4996-b1bc-fc3eb5f29afe"}}}}, {"uuid": "e40a3821-f79c-41ff-a11f-257beeec8693", "name": "a4c79aa9-b586-4019-a8cc-1f031e7905d7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8805170689043904, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.699573894302905, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f706d3b6-bcec-4143-947c-09637f36eb4b", "name": "4a9a3c69-4fac-494e-911d-a58c92abf5fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e40a3821-f79c-41ff-a11f-257beeec8693"}}}]}, {"uuid": "728535a5-4d13-458c-aa9a-988562645181", "name": "load_p1rlv16117_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "204899ec-81e4-4a72-bf70-69b3428a49a1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f706d3b6-bcec-4143-947c-09637f36eb4b"}}}}, {"uuid": "abced025-b8ad-43f5-b022-9c333946660d", "name": "fd6642d2-1b4c-4abb-a17c-1b3bc7447566_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8805170689043904, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.699573894302905, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "70e0dfdd-638f-4f98-ab98-9c223d03f62a", "name": "24ccfd03-28f7-438c-b20e-4534cf87b92e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "abced025-b8ad-43f5-b022-9c333946660d"}}}]}, {"uuid": "fe1c3a28-1973-4061-9d97-344b8b71c76b", "name": "load_p1rlv16117_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "204899ec-81e4-4a72-bf70-69b3428a49a1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "70e0dfdd-638f-4f98-ab98-9c223d03f62a"}}}}, {"uuid": "bac6a7f5-ae27-4fe8-a7cf-97cddabffe8c", "name": "e7fc5122-4ade-4b30-ade6-8435292aa7a3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.667455481738122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8122169683202977, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a44049d7-2b72-4a70-ae59-d4cf28f4dd96", "name": "dfd9db79-c670-4723-b1e2-f1d594819506", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bac6a7f5-ae27-4fe8-a7cf-97cddabffe8c"}}}]}, {"uuid": "a54790f2-6d25-4017-8b73-843660042c32", "name": "load_p1rlv16118_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bca0b3a0-d4cb-4a4a-9b14-aa23d9e5e5fe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a44049d7-2b72-4a70-ae59-d4cf28f4dd96"}}}}, {"uuid": "80b5eeea-9887-41a7-85cb-7fe8263902b9", "name": "1287e37f-dfea-4530-88d3-63e5043f53ba_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.667455481738122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8122169683202977, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "982851d7-722b-4f52-80d3-f957ddec7727", "name": "c6aae283-785e-4c94-99c2-c8e66c57a1c1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "80b5eeea-9887-41a7-85cb-7fe8263902b9"}}}]}, {"uuid": "ffeafe96-58a7-470c-8b86-2f5b72c44780", "name": "load_p1rlv16118_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bca0b3a0-d4cb-4a4a-9b14-aa23d9e5e5fe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "982851d7-722b-4f52-80d3-f957ddec7727"}}}}, {"uuid": "25bbbf41-6602-406b-a32c-c824e7d3bce3", "name": "0b667be0-259d-40f1-9575-2c4e63ff572c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7938373145978153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7193647721316423, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "32413a08-1791-444a-ba67-b830c75c7308", "name": "9a1dab1c-b535-4779-8363-a9f1fe9c4feb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "25bbbf41-6602-406b-a32c-c824e7d3bce3"}}}]}, {"uuid": "9dfd712f-d2cf-46ce-9818-46b2e312025e", "name": "load_p1rlv16119_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0d6e608-d5bf-40d6-9efd-f3b0922e7d77"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "32413a08-1791-444a-ba67-b830c75c7308"}}}}, {"uuid": "786605ce-febf-4166-a149-578bf4bb7da0", "name": "cd48b049-2a20-4ed6-b62c-246263e50b6e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7938373145978153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7193647721316423, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "97395db4-d9c1-4d66-aebe-354134b5507e", "name": "9b4fcdb4-3f1c-4478-8682-b5bb89d111fa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "786605ce-febf-4166-a149-578bf4bb7da0"}}}]}, {"uuid": "6c33851b-87c1-46b9-b27f-c13e571c86ce", "name": "load_p1rlv16119_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0d6e608-d5bf-40d6-9efd-f3b0922e7d77"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "97395db4-d9c1-4d66-aebe-354134b5507e"}}}}, {"uuid": "9379c229-f655-4b12-b5b2-ba95f386a272", "name": "bbd65c20-107d-4409-bdde-9ece0c47256b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3480679486659737, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1241770602848328, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "98069f9e-e37e-45ff-99c5-a57a5a77b0b6", "name": "39a00932-92f4-4396-9859-712f0cd45ddc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9379c229-f655-4b12-b5b2-ba95f386a272"}}}]}, {"uuid": "36732ab5-69dc-40c4-9af4-545e9f2c1d0e", "name": "load_p1rlv16124_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6da4b2d0-66c7-43fb-9aab-3bbac03aa989"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "98069f9e-e37e-45ff-99c5-a57a5a77b0b6"}}}}, {"uuid": "7fcc4de7-0719-40e5-9825-8270e73b0247", "name": "a89a7b08-6b09-47c6-a293-ac726779012b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3480679486659737, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1241770602848328, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a6ed8840-408f-46f0-8c09-e37395a9689c", "name": "33f4efba-208a-4673-b449-f8178987c22c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7fcc4de7-0719-40e5-9825-8270e73b0247"}}}]}, {"uuid": "4fc30b64-b173-47ad-955a-f430d7614906", "name": "load_p1rlv16124_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6da4b2d0-66c7-43fb-9aab-3bbac03aa989"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a6ed8840-408f-46f0-8c09-e37395a9689c"}}}}, {"uuid": "84b6495b-045c-4c87-964c-fb0e558e77de", "name": "4c9cc6ed-5aa4-4a20-888b-79f41b0769f6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6733980323267108, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22626974414284334, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4c058a44-e6ea-4de2-bfb9-d76d5ea629b5", "name": "774e1dff-e6e3-4619-ab4b-3303bc8b65c0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "84b6495b-045c-4c87-964c-fb0e558e77de"}}}]}, {"uuid": "d7ba0cd2-bb48-4804-a327-3721f52bfcea", "name": "load_p1rlv16126_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd41f55a-4b5d-4c19-9787-801072b3b946"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4c058a44-e6ea-4de2-bfb9-d76d5ea629b5"}}}}, {"uuid": "d2d481de-1a78-47c2-86e7-445c35b9b344", "name": "a5af0b62-a953-4f46-8b72-045b3490302b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6733980323267108, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22626974414284334, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "516af154-ecbc-4845-8119-06afe55f66f3", "name": "5ffd92d1-5896-49c7-9684-bf107e2205c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d2d481de-1a78-47c2-86e7-445c35b9b344"}}}]}, {"uuid": "8d7846f5-8730-4e0d-88f5-3e63a4dcc72d", "name": "load_p1rlv16126_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd41f55a-4b5d-4c19-9787-801072b3b946"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "516af154-ecbc-4845-8119-06afe55f66f3"}}}}, {"uuid": "5f332d82-e662-4f4d-ab2a-35c89f90831e", "name": "8905e9c5-ac07-4274-9110-4be751a1f451_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5788343693478561, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0852895205351165, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "04912ec8-5a17-4a85-84f7-0c39abc03477", "name": "746ffaf8-e596-4d3e-82fc-8d4900947fd5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5f332d82-e662-4f4d-ab2a-35c89f90831e"}}}]}, {"uuid": "0a976511-8ae9-4638-8c2c-63edd65633a5", "name": "load_p1rlv16133_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "102b9460-ea9a-4099-b16f-40b8fdf99ef7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "04912ec8-5a17-4a85-84f7-0c39abc03477"}}}}, {"uuid": "43a599a2-b62b-4612-8d2f-5884d76620fd", "name": "0d6082fc-9bea-4439-bc0d-ac1ef6436de8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5788343693478561, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0852895205351165, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9139257c-f68d-4bf2-9810-823f373b594a", "name": "342dc2c1-513f-46d8-b794-8d02a17882cd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "43a599a2-b62b-4612-8d2f-5884d76620fd"}}}]}, {"uuid": "74dd4588-7d28-4eb5-9a8d-313f8d179c7e", "name": "load_p1rlv16133_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "102b9460-ea9a-4099-b16f-40b8fdf99ef7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9139257c-f68d-4bf2-9810-823f373b594a"}}}}, {"uuid": "c0619dfd-a505-47a8-9336-79b3ec4dfb0c", "name": "0ca9810b-c5a2-430d-b6fa-554f188fa7fb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6153595559076463, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2889565281407196, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50198a08-3a43-40dc-8571-73b5bb9cd346", "name": "bfabcc6a-d17b-45ff-a2bd-afb9646f33d0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c0619dfd-a505-47a8-9336-79b3ec4dfb0c"}}}]}, {"uuid": "a2a22920-3529-4a47-9552-fee1019b5ed2", "name": "load_p1rlv16135_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "676de1a3-2dfd-4faa-a057-7739e825d136"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50198a08-3a43-40dc-8571-73b5bb9cd346"}}}}, {"uuid": "5043792a-ef7c-4496-a15d-0af4f7af8cce", "name": "9ed3f16b-eb01-4ebd-8e6a-5e66e0002290_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6153595559076463, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2889565281407196, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dcca11b3-d501-43f0-a281-3bc327b529ce", "name": "4a16d233-6640-4ea1-b6d8-ecb6386d9d6c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5043792a-ef7c-4496-a15d-0af4f7af8cce"}}}]}, {"uuid": "e470734e-dcd9-48c2-815a-0c9c72d1085d", "name": "load_p1rlv16135_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "676de1a3-2dfd-4faa-a057-7739e825d136"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dcca11b3-d501-43f0-a281-3bc327b529ce"}}}}, {"uuid": "cbc9698a-1fef-4fad-8688-d01851548ad5", "name": "7b8bc565-3431-4565-aa4f-646ed7b35c4c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0226237890173833, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.014132802344601372, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aef4db55-d145-4590-8c3a-d09b87ccc493", "name": "3cff0272-99e6-4877-af42-f17a0280d099", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cbc9698a-1fef-4fad-8688-d01851548ad5"}}}]}, {"uuid": "5829fc66-d124-4fd0-973b-6a56109a6c70", "name": "load_p1rlv16139_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c840cf3f-be15-448b-8c03-8942c586b135"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aef4db55-d145-4590-8c3a-d09b87ccc493"}}}}, {"uuid": "610f4b2f-b458-4e1a-a61a-d6632506d009", "name": "b4ba9738-c756-4d73-b5b0-0e95b8cd887d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0226237890173833, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.014132802344601372, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8d4da3d0-1148-4838-9d94-9ade8464da1e", "name": "0260069a-20b1-4411-94cc-9ffb795ebca1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "610f4b2f-b458-4e1a-a61a-d6632506d009"}}}]}, {"uuid": "91c435bb-76f2-471a-809d-13817bea407c", "name": "load_p1rlv16139_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c840cf3f-be15-448b-8c03-8942c586b135"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8d4da3d0-1148-4838-9d94-9ade8464da1e"}}}}, {"uuid": "6042efec-a7ab-418b-92e5-3ab83efbb079", "name": "56214b0e-f9e7-491d-a861-a80f43f5f299_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2601927423507288, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13915962527089715, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f6b6d87d-8daf-4cbb-9619-84739c833ecb", "name": "7a214c76-fcac-455f-b323-84b6a728afad", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6042efec-a7ab-418b-92e5-3ab83efbb079"}}}]}, {"uuid": "47b4cccd-4f53-45f0-9b6e-01951fc190d6", "name": "load_p1rlv16146_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6d21c357-1033-45e1-84a0-b82ceafe6ab8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f6b6d87d-8daf-4cbb-9619-84739c833ecb"}}}}, {"uuid": "fd23a6b8-cf91-41dc-b37f-77c1188910ba", "name": "f5874288-2c7b-457e-a546-a9300f69e414_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2601927423507288, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13915962527089715, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c729d70-656f-48bf-874f-573f7d3fad6c", "name": "d42b61b5-1b5d-4c92-8376-63d5c0d743ef", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fd23a6b8-cf91-41dc-b37f-77c1188910ba"}}}]}, {"uuid": "3b572804-1bf4-452f-8c8a-7e83f2a7df9d", "name": "load_p1rlv16146_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6d21c357-1033-45e1-84a0-b82ceafe6ab8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c729d70-656f-48bf-874f-573f7d3fad6c"}}}}, {"uuid": "944e9d08-58c5-471c-b02f-d03631e3b3fd", "name": "4cf50889-ff51-4daa-9594-f9ca031ddf2f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.954715654212962, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.874926311982217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ba4c0a9a-ea5a-47e6-9087-6ccffa088ae3", "name": "06820ee3-82e9-4d51-8bd8-82afe2e820d6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "944e9d08-58c5-471c-b02f-d03631e3b3fd"}}}]}, {"uuid": "e1d9d634-aada-4a41-9782-7b61414d440c", "name": "load_p1rlv16149_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b15792ca-a6bd-47e5-8c67-5c3076174848"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ba4c0a9a-ea5a-47e6-9087-6ccffa088ae3"}}}}, {"uuid": "d82e6c12-c88d-44bf-acac-1c129736f972", "name": "60850e0b-cb39-4f3d-8296-63d7efa32f9f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.954715654212962, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.874926311982217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d0d23c7c-b137-4edb-aa89-8cd506803c05", "name": "1f02f919-b8d7-4dcc-be93-0416be171418", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d82e6c12-c88d-44bf-acac-1c129736f972"}}}]}, {"uuid": "eee641f4-7495-49d4-b0c4-ccad20246869", "name": "load_p1rlv16149_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b15792ca-a6bd-47e5-8c67-5c3076174848"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d0d23c7c-b137-4edb-aa89-8cd506803c05"}}}}, {"uuid": "3fb5e67e-7604-49e0-84b3-242f0a723658", "name": "4f023723-4c1c-4054-982b-8b339729e62e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.199861964544811, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5137601155429989, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "babc2fd3-3af8-477f-83da-3053e5d55d9a", "name": "3a352fc0-24f9-40ff-a303-68dd6b65b760", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3fb5e67e-7604-49e0-84b3-242f0a723658"}}}]}, {"uuid": "62d2f921-6b29-450f-8efd-cc005b8fc836", "name": "load_p1rlv16156_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "74edd9e9-24a5-4b36-8ca8-24ef2fa3e972"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "babc2fd3-3af8-477f-83da-3053e5d55d9a"}}}}, {"uuid": "c638bf32-7feb-4a80-98d7-3f15f7f07683", "name": "c15e25d9-ee81-47b4-93ca-1da39af6a5ec_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.199861964544811, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5137601155429989, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "02dc8948-4499-440f-9062-51b4df1185ed", "name": "af9e2be7-aec7-47c4-9506-4e350d02b583", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c638bf32-7feb-4a80-98d7-3f15f7f07683"}}}]}, {"uuid": "ea4d056f-ebac-4652-a3bb-2f0393cf3e9b", "name": "load_p1rlv16156_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "74edd9e9-24a5-4b36-8ca8-24ef2fa3e972"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "02dc8948-4499-440f-9062-51b4df1185ed"}}}}, {"uuid": "95af027f-f060-48cf-ba7f-7a6bfe81e4d9", "name": "7444f369-9eab-404e-875f-0a874429e148_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8668291909105112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7572719732007044, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2977e7e4-a182-4eda-a621-665cdfea8b72", "name": "7723bebb-c070-4919-b2a4-43332f162739", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "95af027f-f060-48cf-ba7f-7a6bfe81e4d9"}}}]}, {"uuid": "f8017a87-cdf4-45bd-82eb-e1c5d21ff905", "name": "load_p1rlv16157_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6efff4f7-c67b-4cfb-a72d-30b6616825b1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2977e7e4-a182-4eda-a621-665cdfea8b72"}}}}, {"uuid": "0d1ea309-327f-4df9-a825-c720410aea31", "name": "2cd1e795-b6d5-4a6c-aed6-ef98f90064e8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8668291909105112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7572719732007044, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2f7cb9e1-5e4f-43bc-adab-f41910e887df", "name": "0e55a0a1-2deb-495a-9a56-f39a4c2ff82b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0d1ea309-327f-4df9-a825-c720410aea31"}}}]}, {"uuid": "289f48fe-200b-4ef8-bb85-415fb62457eb", "name": "load_p1rlv16157_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6efff4f7-c67b-4cfb-a72d-30b6616825b1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2f7cb9e1-5e4f-43bc-adab-f41910e887df"}}}}, {"uuid": "aadd63b4-0be3-4930-aa43-d0e89a049dde", "name": "340caec7-a6a9-4f57-a9f1-7c0cdd25330e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.927062407458527, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.5614641711041375, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "94718418-e166-4c74-a9f9-afa3c38c5c5e", "name": "10bccbfd-02a7-465a-ae9d-34e6334107d8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aadd63b4-0be3-4930-aa43-d0e89a049dde"}}}]}, {"uuid": "ad302c42-a4e0-4487-baea-30eb493be87c", "name": "load_p1rlv16158_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b85e180a-8eb4-4acc-a816-d99758cc16ea"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "94718418-e166-4c74-a9f9-afa3c38c5c5e"}}}}, {"uuid": "35d8cb9b-ea2b-4ad7-84b6-3ea93abe91cd", "name": "14d8755e-45f8-4f0a-ace9-26a251575b0d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.927062407458527, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.5614641711041375, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e7a4f331-391c-41c2-8708-af3c62c444b1", "name": "ad66d882-04f1-42ea-9b5d-85bf29f490a6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "35d8cb9b-ea2b-4ad7-84b6-3ea93abe91cd"}}}]}, {"uuid": "3d2b97fa-a69b-400b-8c6a-7edcc9ec5e98", "name": "load_p1rlv16158_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b85e180a-8eb4-4acc-a816-d99758cc16ea"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e7a4f331-391c-41c2-8708-af3c62c444b1"}}}}, {"uuid": "8fa57b6a-1070-49a0-ab8c-6fc7653fa1b5", "name": "d8de8e69-c8e2-40bf-ab7d-b1efcb08417f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6923563615826267, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8186846587164974, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f8c69361-b012-4381-9baf-f47e2ace3e35", "name": "7352512f-5a4e-42bf-a268-c90fbaa10bfb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8fa57b6a-1070-49a0-ab8c-6fc7653fa1b5"}}}]}, {"uuid": "ae35f4ab-be01-4151-b28c-bc457b2eaf1e", "name": "load_p1rlv16168_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fb5abb7-dd79-49aa-9185-88a90bb45bc7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f8c69361-b012-4381-9baf-f47e2ace3e35"}}}}, {"uuid": "5518dcf0-ca6d-4c31-8e14-b1fbfcbfc9a4", "name": "8f65fe76-7ec3-4c39-8ade-f8cda2b5adb4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6923563615826267, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8186846587164974, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ee0339eb-6bb9-4623-a309-40f8be220020", "name": "7b56c783-647d-4445-a892-aeeeb23f2214", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5518dcf0-ca6d-4c31-8e14-b1fbfcbfc9a4"}}}]}, {"uuid": "e1291582-16b4-44ff-8b20-af36b4546a35", "name": "load_p1rlv16168_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fb5abb7-dd79-49aa-9185-88a90bb45bc7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ee0339eb-6bb9-4623-a309-40f8be220020"}}}}, {"uuid": "759b6c81-1eff-41f0-91b3-2fa957406b90", "name": "6ceb5dc2-80f4-4575-a4de-ab9a62fd34ed_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.160237576416993, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 5.832362811342285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9e794faa-cc78-43af-92ad-d55e903534c0", "name": "79d156a2-e7af-4303-a866-c151ec2d5e3b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "759b6c81-1eff-41f0-91b3-2fa957406b90"}}}]}, {"uuid": "d37c76fa-d11a-45d6-b583-c9f1d1afe258", "name": "load_p1rlv16177_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbbe8401-53a1-4ce7-9ce1-02f547055d95"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9e794faa-cc78-43af-92ad-d55e903534c0"}}}}, {"uuid": "1ef1acd9-ea6f-4427-8451-dd0f3a5e227b", "name": "ece91088-fedf-4f6c-8fd4-020c63ffe0ae_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.160237576416993, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 5.832362811342285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "11f69efc-00f8-446d-a326-f00471de567f", "name": "ecf2035a-b5a3-40e3-8b14-7cc42e5d2d52", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1ef1acd9-ea6f-4427-8451-dd0f3a5e227b"}}}]}, {"uuid": "11b248f1-2e87-4e52-99d5-ace7c2a21dd7", "name": "load_p1rlv16177_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbbe8401-53a1-4ce7-9ce1-02f547055d95"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "11f69efc-00f8-446d-a326-f00471de567f"}}}}, {"uuid": "7db3fc2b-717d-425d-8ce2-4c368ad8a20a", "name": "31da6973-780b-499b-be21-8c61b7e98b6c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.060834559711965, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4528637167980347, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1ff20224-d53d-4d70-9fc9-a1f7ebf9208d", "name": "0ec4d3cb-1481-450d-b00b-af279a4ef278", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7db3fc2b-717d-425d-8ce2-4c368ad8a20a"}}}]}, {"uuid": "28082638-16ec-4f1c-8f35-73032dfe4ae6", "name": "load_p1rlv16178_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "807b0bef-0d34-44a9-a2a9-0c0a11f4ea8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1ff20224-d53d-4d70-9fc9-a1f7ebf9208d"}}}}, {"uuid": "811f9d5d-2c38-4000-ad90-2407c8ba381b", "name": "2ef15f6f-7918-40d9-b6ca-cc29041b0dbd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.060834559711965, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4528637167980347, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2a3acf25-d5eb-4013-b4a4-c3ae643867c7", "name": "ea4bf838-2578-43ad-adbb-7653cfafd7e0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "811f9d5d-2c38-4000-ad90-2407c8ba381b"}}}]}, {"uuid": "ecac8be1-ae8c-4ff3-a56b-ef59dff62e08", "name": "load_p1rlv16178_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "807b0bef-0d34-44a9-a2a9-0c0a11f4ea8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2a3acf25-d5eb-4013-b4a4-c3ae643867c7"}}}}, {"uuid": "cd990560-ccf7-4e47-b0a8-e54eaf37e8dd", "name": "9b055f05-34e8-4444-b73c-ac788fd443a8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8288850538480296, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31695217299610473, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b66da1a3-044a-46d1-bc15-fd8daeca6076", "name": "9d20ad51-c6df-4719-bbb3-fc460d08236b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cd990560-ccf7-4e47-b0a8-e54eaf37e8dd"}}}]}, {"uuid": "bb67aa8e-9868-4bb1-8164-10d1048423fa", "name": "load_p1rlv16197_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "92a37082-36d4-4eca-95e4-88dbcacd6db5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b66da1a3-044a-46d1-bc15-fd8daeca6076"}}}}, {"uuid": "9f6bbe6b-f152-41c4-9e9b-b4c8e195801f", "name": "24cc580e-f578-4485-b2b0-0fd8d9984bc2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8288850538480296, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31695217299610473, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2fac40fd-4c72-4eab-a08a-7602d5b740a2", "name": "77a10d6c-ca60-44f0-b5b2-ce72b05c0f2d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9f6bbe6b-f152-41c4-9e9b-b4c8e195801f"}}}]}, {"uuid": "61115f7b-14ea-43b1-98ab-6a4501c7e755", "name": "load_p1rlv16197_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "92a37082-36d4-4eca-95e4-88dbcacd6db5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2fac40fd-4c72-4eab-a08a-7602d5b740a2"}}}}, {"uuid": "51f2c6a7-abf8-40e1-b63a-5de2319c2e2e", "name": "8b4c8e30-f340-4d25-b10e-33fb7f7905c5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5775901800387742, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6237657200291109, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "597b73a2-1034-487f-99c0-2d74dc99d141", "name": "887f0fd4-281b-4a24-8373-82d40fd5bab5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "51f2c6a7-abf8-40e1-b63a-5de2319c2e2e"}}}]}, {"uuid": "fb695a11-0908-4b19-a9be-e8d1859b4c5c", "name": "load_p1rlv16200_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1aacea55-115d-46c3-9590-725cf5040f38"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "597b73a2-1034-487f-99c0-2d74dc99d141"}}}}, {"uuid": "e534beb3-a4d4-48f8-a6e7-7359ec2f1afe", "name": "a6e1477d-0917-4b47-9805-9ce404d0acf9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5775901800387742, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6237657200291109, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f8e68d22-1c77-4be7-ab6d-8b8d1a688b41", "name": "4b0eb596-282f-40d0-85d6-92ba67973883", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e534beb3-a4d4-48f8-a6e7-7359ec2f1afe"}}}]}, {"uuid": "188a1dbc-8092-4633-9710-6db102bbac68", "name": "load_p1rlv16200_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1aacea55-115d-46c3-9590-725cf5040f38"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f8e68d22-1c77-4be7-ab6d-8b8d1a688b41"}}}}, {"uuid": "d64fad99-5581-447e-a562-7368e6df2f92", "name": "925da18f-b233-4144-a409-1b24377fec95_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4950137537296666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31506625700854357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c1a632ee-3fca-43e2-a0b4-e237df300bec", "name": "e5fd1e11-75bd-45cf-8120-169d18ecd45b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d64fad99-5581-447e-a562-7368e6df2f92"}}}]}, {"uuid": "8113cfc0-7014-447a-aa9a-a78e4b9a2255", "name": "load_p1rlv16201_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68aa5cc5-f6bf-4417-8653-747c56b37b5e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c1a632ee-3fca-43e2-a0b4-e237df300bec"}}}}, {"uuid": "a0016079-70b3-4a6d-a640-8c3b1e6f6366", "name": "051018c9-0438-41c2-aad2-042ec84613e5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4950137537296666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31506625700854357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "690ba879-c2fe-4b7d-bf13-de4c8ff82366", "name": "eb8acc83-e967-44f1-97f1-480a94e04f1a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a0016079-70b3-4a6d-a640-8c3b1e6f6366"}}}]}, {"uuid": "1a299d11-654b-42f2-9549-0e1ebc5bfee8", "name": "load_p1rlv16201_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68aa5cc5-f6bf-4417-8653-747c56b37b5e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "690ba879-c2fe-4b7d-bf13-de4c8ff82366"}}}}, {"uuid": "82f80507-7e59-4d25-92e4-063d5352e131", "name": "2b930e05-b5ca-4776-b53c-2e93994c5ae3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.668048225868244, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.178282395400973, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "44a99c88-77f8-4547-a76c-e4cd0ceb5057", "name": "6a5b1ff0-2a62-4dae-b3c2-3f72552aaf24", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "82f80507-7e59-4d25-92e4-063d5352e131"}}}]}, {"uuid": "4e5070b5-da69-4033-a231-1ac0d07dd50f", "name": "load_p1rlv16206_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ca42395-8d67-4e83-80ec-159cacb490f8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "44a99c88-77f8-4547-a76c-e4cd0ceb5057"}}}}, {"uuid": "10efa989-c321-4627-b3ea-58a01ecb6c67", "name": "3087cff4-d666-4dc9-983f-07818d2217b4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.668048225868244, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.178282395400973, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6171b61a-c649-477b-b369-585b3d4f9d67", "name": "fcfee667-3a76-4915-a802-ec7625d41b65", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "10efa989-c321-4627-b3ea-58a01ecb6c67"}}}]}, {"uuid": "e6be7fda-f439-4963-ac3f-0d593ded7427", "name": "load_p1rlv16206_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ca42395-8d67-4e83-80ec-159cacb490f8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6171b61a-c649-477b-b369-585b3d4f9d67"}}}}, {"uuid": "6e3a2dd8-9d14-4656-97e1-29404e1858ed", "name": "db2f9d9c-7cc0-48af-b2fa-b337078e7f43_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8202631342288826, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.26720803692022926, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4ca4a8b8-2848-4562-84e4-b3091cabb297", "name": "a05549c7-64ca-4f21-8d1c-9ff1b5cf4180", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6e3a2dd8-9d14-4656-97e1-29404e1858ed"}}}]}, {"uuid": "38baae80-9e2b-4574-b0b8-80c9191778ea", "name": "load_p1rlv16209_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf413742-18c8-483d-b8f1-f125f95323da"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4ca4a8b8-2848-4562-84e4-b3091cabb297"}}}}, {"uuid": "0a051704-0824-4b50-9da2-9a88776bbf00", "name": "00f42130-c93c-426a-8da9-b9e3b3889a1a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8202631342288826, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.26720803692022926, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5072fd2e-6a5d-4f41-94d4-f4b07524235e", "name": "d5b24dcc-7afd-4cb1-a5ef-103b1cf30946", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0a051704-0824-4b50-9da2-9a88776bbf00"}}}]}, {"uuid": "4506020b-9977-4001-b008-07eb54d22c69", "name": "load_p1rlv16209_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf413742-18c8-483d-b8f1-f125f95323da"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5072fd2e-6a5d-4f41-94d4-f4b07524235e"}}}}, {"uuid": "f9622ad8-9c05-4623-94d2-fc3db1729d57", "name": "7ac7b347-6227-4658-8a0e-8d53c99901eb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.621947646480353, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0332384495271123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fa3d3118-0271-46bd-a8fc-ea328754fe18", "name": "cd84c6d0-7df2-4a20-845b-24648ee492c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f9622ad8-9c05-4623-94d2-fc3db1729d57"}}}]}, {"uuid": "da1537bc-3902-43ab-92af-239cf99fac5e", "name": "load_p1rlv16210_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fd05f3c-df77-45bc-8686-458b681a3d08"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fa3d3118-0271-46bd-a8fc-ea328754fe18"}}}}, {"uuid": "73b43497-48f7-4318-bc2b-74717054e651", "name": "2ef7c5ad-edd9-4aea-b435-2de079dea7a2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.621947646480353, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0332384495271123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f7675120-31a6-41cd-a416-bfe9e9b58a99", "name": "7c507e19-95e4-471d-8f33-0ca7d1770368", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "73b43497-48f7-4318-bc2b-74717054e651"}}}]}, {"uuid": "a85789d2-5bdf-40c4-8db0-32a010ac2bb9", "name": "load_p1rlv16210_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fd05f3c-df77-45bc-8686-458b681a3d08"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f7675120-31a6-41cd-a416-bfe9e9b58a99"}}}}, {"uuid": "bd71cb50-0006-42e9-ad81-75ecd8b79a48", "name": "f3080d62-ac16-4d83-8083-e140467ac72e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.08053934867757, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.19082517830123075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b64a5f67-da86-43f2-98ed-6d4f37fc6df6", "name": "9d0be648-054f-4b89-81b6-d49caf009d06", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bd71cb50-0006-42e9-ad81-75ecd8b79a48"}}}]}, {"uuid": "687d59e4-ec09-42fa-8290-945ee573225e", "name": "load_p1rlv16221_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9761003-33fa-482a-967b-b508ab67c19f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b64a5f67-da86-43f2-98ed-6d4f37fc6df6"}}}}, {"uuid": "c92936ad-112a-42cf-a795-6beca08af2e6", "name": "90c9377d-b6c7-4142-bdcc-518269e98dc2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.08053934867757, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.19082517830123075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "248dedcd-95bc-4a77-8661-b69cae451e77", "name": "27753590-42a1-496c-a0eb-79e1a17dd545", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c92936ad-112a-42cf-a795-6beca08af2e6"}}}]}, {"uuid": "25e15c21-5534-423f-b539-7fcdee678078", "name": "load_p1rlv16221_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9761003-33fa-482a-967b-b508ab67c19f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "248dedcd-95bc-4a77-8661-b69cae451e77"}}}}, {"uuid": "2e3a56f0-26d6-49c4-8278-48212669b3a8", "name": "a2b6d15a-95b2-48e7-9736-fea5cb3cf4d2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.0707881481560175, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.1283140369898392, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7d012a1d-6742-41dd-88a6-1cf39c22a3ff", "name": "86520804-049f-4fb5-8729-020319b66c13", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2e3a56f0-26d6-49c4-8278-48212669b3a8"}}}]}, {"uuid": "63aab616-7791-487d-a08b-51972220df8a", "name": "load_p1rlv16222_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4809afc1-2d3d-491d-80e5-9cd4e8da08f2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7d012a1d-6742-41dd-88a6-1cf39c22a3ff"}}}}, {"uuid": "f8befad7-db52-4f5b-bf30-4ec36de002d5", "name": "52968539-b947-42a1-b6e9-cad8ddf1b9e4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.0707881481560175, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.1283140369898392, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bf537ed1-e312-40d7-9588-585e4082e6de", "name": "eeab61f2-224c-4641-98d5-f33d205fe2bf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8befad7-db52-4f5b-bf30-4ec36de002d5"}}}]}, {"uuid": "9dc56401-aa82-4081-871e-dba02af9eb1d", "name": "load_p1rlv16222_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4809afc1-2d3d-491d-80e5-9cd4e8da08f2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bf537ed1-e312-40d7-9588-585e4082e6de"}}}}, {"uuid": "6d324efc-b032-4759-9496-6fcc6bf9f013", "name": "6730beef-de2e-4ef5-8580-c2053e941b70_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7997673490012955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.772957044307952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e7aef740-a876-4527-8c3a-81de3fb33468", "name": "e3c53125-15b6-4022-929c-1aade13ba79e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6d324efc-b032-4759-9496-6fcc6bf9f013"}}}]}, {"uuid": "1dd65483-4544-46ca-87b9-86004f8af419", "name": "load_p1rlv16228_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8767650-39c5-4d4a-80ce-af408c246599"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e7aef740-a876-4527-8c3a-81de3fb33468"}}}}, {"uuid": "08768275-2e22-4df1-8fcf-f8786fd610ab", "name": "75ed1a21-6584-4154-8564-29660d44dd60_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7997673490012955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.772957044307952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "86278f7c-6d66-40a6-9db0-49a2cb509a8a", "name": "017f4552-9fda-4e60-a865-b73ac6f60513", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "08768275-2e22-4df1-8fcf-f8786fd610ab"}}}]}, {"uuid": "23331b8c-8dbd-41bb-96e7-4a9ee02aa8ce", "name": "load_p1rlv16228_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8767650-39c5-4d4a-80ce-af408c246599"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "86278f7c-6d66-40a6-9db0-49a2cb509a8a"}}}}, {"uuid": "2384208f-c3da-4a5f-8774-5ed0b42d1775", "name": "9fb213e2-f60e-45b8-9dec-810063737f0f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.941898785419248, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8498359578625553, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d033bc93-d36e-4320-b499-6180fc5e3379", "name": "6ed32a0e-dbac-4c67-90da-a12fae14e1c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2384208f-c3da-4a5f-8774-5ed0b42d1775"}}}]}, {"uuid": "90c28d38-88fc-4f21-a316-fcf16d1a1721", "name": "load_p1rlv16235_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56b91b3f-dfdd-41bf-9d2e-a8183077c752"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d033bc93-d36e-4320-b499-6180fc5e3379"}}}}, {"uuid": "8ef99890-745e-4393-8325-fb5aa64640bc", "name": "cfc09689-4a41-4315-af0c-0f9e1c456e86_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.941898785419248, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8498359578625553, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "925e289d-82ac-4ac3-8e06-044ce8c912dc", "name": "c19e020c-bc6d-4120-b46a-4ab23c053afc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ef99890-745e-4393-8325-fb5aa64640bc"}}}]}, {"uuid": "f7a053ff-c115-476d-8880-bde065bababd", "name": "load_p1rlv16235_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56b91b3f-dfdd-41bf-9d2e-a8183077c752"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "925e289d-82ac-4ac3-8e06-044ce8c912dc"}}}}, {"uuid": "25e3363b-55dd-43a6-aa7c-52a7119bfeea", "name": "17149634-af64-479f-b5a7-cb5c71a5e4ed_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.992945339168608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.937847717707562, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "208c43d1-94a0-4344-90df-52dc7bd511d7", "name": "d6af770d-529f-4890-9352-0930b950bbb3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "25e3363b-55dd-43a6-aa7c-52a7119bfeea"}}}]}, {"uuid": "02061d0f-f540-4f78-aa26-193fbcf05a3c", "name": "load_p1rlv16239_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9642fa30-e5f7-42f1-8fda-ab75a265d25a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "208c43d1-94a0-4344-90df-52dc7bd511d7"}}}}, {"uuid": "87ba6520-cd25-4ef3-ac5b-39ccf50910aa", "name": "4e13ba8f-b575-487a-8493-6579b0d9c471_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.992945339168608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.937847717707562, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "00d96727-8577-4bde-9d0d-28049794d64a", "name": "47aeb06f-b5f7-464f-b4ff-c4d59927eb8f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "87ba6520-cd25-4ef3-ac5b-39ccf50910aa"}}}]}, {"uuid": "f591e871-f291-4273-b6bb-54f9144cd7f4", "name": "load_p1rlv16239_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9642fa30-e5f7-42f1-8fda-ab75a265d25a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "00d96727-8577-4bde-9d0d-28049794d64a"}}}}, {"uuid": "46676f65-412e-48ff-9fb8-53394bd9f99a", "name": "91b27021-aa12-45e7-aa70-f6bc9731a5b4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9337862827800336, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34425772205755256, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "415a56cf-38ae-4744-89b4-1e397956b57e", "name": "cf8aa6d7-3d6f-4c32-97a6-8b10840f41ba", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "46676f65-412e-48ff-9fb8-53394bd9f99a"}}}]}, {"uuid": "807b2c7b-8421-4be2-9991-525a59224a3a", "name": "load_p1rlv16242_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e82036d9-e6c8-42c3-b45b-30bef6902bbc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "415a56cf-38ae-4744-89b4-1e397956b57e"}}}}, {"uuid": "b8173146-9863-4a87-9624-704836c1d974", "name": "2907befd-8fc1-4310-b863-979de3223721_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9337862827800336, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34425772205755256, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cdd8a788-aa78-4ca7-9f7d-a5b151748276", "name": "fc5124bd-3d4c-4027-a48c-6b95c5adf4ee", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b8173146-9863-4a87-9624-704836c1d974"}}}]}, {"uuid": "c856e52e-6577-42dc-b16d-98eb2b4ba2d7", "name": "load_p1rlv16242_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e82036d9-e6c8-42c3-b45b-30bef6902bbc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cdd8a788-aa78-4ca7-9f7d-a5b151748276"}}}}, {"uuid": "bb93cf86-abd1-416e-9d9a-a6c9bd1ce715", "name": "ad19cd3b-2575-4a5b-b842-a965054e127a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7430249960912554, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9646854683366036, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7c4fa019-913f-42d9-8487-43baf7140118", "name": "85a9a0cd-f507-4cdf-9c94-9642caedde3c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bb93cf86-abd1-416e-9d9a-a6c9bd1ce715"}}}]}, {"uuid": "34c8cbbb-410b-4176-b515-fc86aa512951", "name": "load_p1rlv16243_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20818cc7-617e-4ab7-8f7c-31eea6496a02"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7c4fa019-913f-42d9-8487-43baf7140118"}}}}, {"uuid": "3d681fe6-c130-41b9-b824-051414bea0ef", "name": "b35ab247-2792-4051-a8cd-d1379991b7b5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7430249960912554, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9646854683366036, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c0caf009-8d97-4ccf-a18e-1c4744b66c66", "name": "7fa22bc4-e544-4985-8c30-952326b87d83", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3d681fe6-c130-41b9-b824-051414bea0ef"}}}]}, {"uuid": "067e83ef-33c4-4d7e-b6d2-b897ea32998f", "name": "load_p1rlv16243_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20818cc7-617e-4ab7-8f7c-31eea6496a02"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c0caf009-8d97-4ccf-a18e-1c4744b66c66"}}}}, {"uuid": "bbb7d194-ee30-4c7e-82bf-d6a343c5c099", "name": "c973ef57-4bea-4bf2-a02f-0b9f74f561b2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2766983969851713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5028612878254624, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0be0b900-102a-4d59-842e-2b164d4f82a4", "name": "02e72792-8785-464d-b508-fbbd4ee69536", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bbb7d194-ee30-4c7e-82bf-d6a343c5c099"}}}]}, {"uuid": "13aefa76-b966-4fcc-8857-ad70e07e674b", "name": "load_p1rlv16244_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0164339-acc1-4b95-aa31-3af42cf943f7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0be0b900-102a-4d59-842e-2b164d4f82a4"}}}}, {"uuid": "a78da743-46a7-4c08-a8e1-ceaf896565d8", "name": "ae676b84-86dd-4afa-a0a7-51a4b2fba285_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2766983969851713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5028612878254624, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a629ed77-26cc-4809-8503-c28eae2996f2", "name": "78479dde-0af5-487b-83df-a28f1a9a92fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a78da743-46a7-4c08-a8e1-ceaf896565d8"}}}]}, {"uuid": "fc7bdb18-05b5-4508-89cf-6b2d0be753ae", "name": "load_p1rlv16244_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0164339-acc1-4b95-aa31-3af42cf943f7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a629ed77-26cc-4809-8503-c28eae2996f2"}}}}, {"uuid": "49f92419-0d54-443b-8d43-33d0b1876020", "name": "26f20116-38be-47a3-a72d-30669c1a648e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.13715702476687, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3795210711832634, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6f4efc49-d644-487e-9eff-4333bb378c29", "name": "99f989f4-5b24-45b4-9f1b-0e1a29073b7f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "49f92419-0d54-443b-8d43-33d0b1876020"}}}]}, {"uuid": "79fe76ff-6ba6-465f-95d8-8a6c22d2ab39", "name": "load_p1rlv16245_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3783c838-b72e-42cd-8b0b-3005bca3cf5e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6f4efc49-d644-487e-9eff-4333bb378c29"}}}}, {"uuid": "009fce19-1ad7-46eb-a6a7-2de897f44fe7", "name": "7a433bcd-05e4-4262-b28a-b0dccca99d3e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.13715702476687, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3795210711832634, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b117b8fd-198c-4662-b556-190230cca40b", "name": "fbdb871d-ac90-4986-afb4-98f9f3c46423", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "009fce19-1ad7-46eb-a6a7-2de897f44fe7"}}}]}, {"uuid": "3a382cd8-e1bc-4c1b-9592-198db8d95239", "name": "load_p1rlv16245_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3783c838-b72e-42cd-8b0b-3005bca3cf5e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b117b8fd-198c-4662-b556-190230cca40b"}}}}, {"uuid": "c2a99cd4-f825-458d-884c-65bedb2d91ce", "name": "bb10f447-0dd9-47bb-9b43-bb2438d3ad0c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.133603663599094, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7fbeaf93-c0a2-41e2-93c1-81d2463975fc", "name": "4d94c9b3-5a90-493c-a165-f922cec9ba41", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c2a99cd4-f825-458d-884c-65bedb2d91ce"}}}]}, {"uuid": "cc498e82-9ab9-40a7-b1e3-362b034829b2", "name": "load_p1rlv16246_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd2dc2db-787a-4732-bae4-01186082a92d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7fbeaf93-c0a2-41e2-93c1-81d2463975fc"}}}}, {"uuid": "8fd4c161-fb13-4a88-ad9f-6d89a71bc353", "name": "7c4bb292-324f-44f6-ab57-7d5ef8525060_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.133603663599094, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6b2cf3bb-66d6-44aa-9f18-3339fa5074de", "name": "8e4d0312-8875-4ed0-bf5e-94b2e7461be0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8fd4c161-fb13-4a88-ad9f-6d89a71bc353"}}}]}, {"uuid": "3d44bacf-37ae-4eeb-9ec0-31965edfded3", "name": "load_p1rlv16246_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd2dc2db-787a-4732-bae4-01186082a92d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6b2cf3bb-66d6-44aa-9f18-3339fa5074de"}}}}, {"uuid": "4d5e82c2-d868-4b53-a073-007053cd037b", "name": "20d0f761-6902-4647-9a0e-5e6c1c69413f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0472938281946713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.40441110210881914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "03eef06c-dfb2-4e26-80eb-b44907416c52", "name": "7b959a9f-b5f7-4d58-aebb-ee74e4f8b29b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4d5e82c2-d868-4b53-a073-007053cd037b"}}}]}, {"uuid": "f2fe1b05-e077-42ca-8efb-c10275765edd", "name": "load_p1rlv16247_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8d5e9b7-dc95-41f9-8547-99d5e2eba874"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "03eef06c-dfb2-4e26-80eb-b44907416c52"}}}}, {"uuid": "b1b47682-7ade-48a9-9a13-7e549a05e897", "name": "11ad2d15-c8ad-4963-8a08-54201a231804_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0472938281946713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.40441110210881914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6e7104d0-2c2d-41a3-9fb8-9d72be0b0dcc", "name": "c0a8c15a-8ba9-44ac-98c5-b3d045ad36dc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b1b47682-7ade-48a9-9a13-7e549a05e897"}}}]}, {"uuid": "8111a614-f55e-4424-8ee4-434bbcae8351", "name": "load_p1rlv16247_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8d5e9b7-dc95-41f9-8547-99d5e2eba874"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6e7104d0-2c2d-41a3-9fb8-9d72be0b0dcc"}}}}, {"uuid": "9ff37076-e004-4425-a80c-3d3d8c99522d", "name": "2549db86-05ca-4352-bb29-e32892d23a92_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.398785600945231, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1157218527290627, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4613a88c-f171-4465-bc15-c79e9df82900", "name": "0c625c40-07ce-44eb-9850-e9eb6a7c6ba8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9ff37076-e004-4425-a80c-3d3d8c99522d"}}}]}, {"uuid": "9d5ffda1-a68b-4bd1-85eb-2989a2b9fb13", "name": "load_p1rlv16248_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "feb24768-feab-40f0-acc3-0b2bb500133a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4613a88c-f171-4465-bc15-c79e9df82900"}}}}, {"uuid": "0a7dc028-61ac-49b0-9e30-18f48a26ad17", "name": "807c8942-2d0d-455f-afc7-13dfc93159de_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.398785600945231, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1157218527290627, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "28bb9324-fb40-438d-a836-6880409cf4f9", "name": "fbc6768a-8fd6-4b85-a6be-605f380e2b45", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0a7dc028-61ac-49b0-9e30-18f48a26ad17"}}}]}, {"uuid": "8485dd6a-1c4a-49e3-803f-5635ffbe888b", "name": "load_p1rlv16248_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "feb24768-feab-40f0-acc3-0b2bb500133a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "28bb9324-fb40-438d-a836-6880409cf4f9"}}}}, {"uuid": "cdb85435-3309-47db-acb8-3a4839a89c95", "name": "8c0a59e0-937c-4bfb-bf0a-c0e84b341307_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c8744706-ab22-439f-abb2-6e1d0a500e5e", "name": "66c41bf8-3865-446e-a90b-1d5888d1f614", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cdb85435-3309-47db-acb8-3a4839a89c95"}}}]}, {"uuid": "ce7419eb-0876-4a0d-b3d2-2e8cc904a6ea", "name": "load_p1rlv16252_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5c6a5f39-0654-4e73-8050-c6c4ad9d54e6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c8744706-ab22-439f-abb2-6e1d0a500e5e"}}}}, {"uuid": "e477f4cc-f400-4b29-89ac-275cfab6836f", "name": "df8251ad-abb0-4b52-b0c6-32bcf56fc79f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3b142e78-a993-450e-84ba-90be31f9ed69", "name": "1312c866-677e-447c-9620-99ea07dd6e0e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e477f4cc-f400-4b29-89ac-275cfab6836f"}}}]}, {"uuid": "2350796d-9a55-42a8-9a85-fdefcd538274", "name": "load_p1rlv16252_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5c6a5f39-0654-4e73-8050-c6c4ad9d54e6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3b142e78-a993-450e-84ba-90be31f9ed69"}}}}, {"uuid": "e3b7d7a4-5f3a-41a4-b70a-5e0ec4999e4b", "name": "ee6b1bea-4ade-4e58-a2c1-0ea641f587d7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.430610855643826, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18457628630998096, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1db2a9f7-c324-4edd-9719-093ac13f48d1", "name": "0d069785-32ae-4270-b536-d1544147545c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e3b7d7a4-5f3a-41a4-b70a-5e0ec4999e4b"}}}]}, {"uuid": "33949412-5af7-4de0-9332-1bc2058e7b37", "name": "load_p1rlv16253_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "268549c6-0c8b-44ac-b933-316b36645366"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1db2a9f7-c324-4edd-9719-093ac13f48d1"}}}}, {"uuid": "53cc9afa-9837-48ce-923f-20253d4fbcf7", "name": "6f33ad52-125d-41ed-b940-d62e20895233_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.430610855643826, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18457628630998096, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9ba7469e-8d1d-4dd6-9195-589e6a163b26", "name": "e7513ceb-a589-46a9-97f8-ad86a84e318a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "53cc9afa-9837-48ce-923f-20253d4fbcf7"}}}]}, {"uuid": "74f69ee4-622b-4963-9559-731cd64ccc6a", "name": "load_p1rlv16253_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "268549c6-0c8b-44ac-b933-316b36645366"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9ba7469e-8d1d-4dd6-9195-589e6a163b26"}}}}, {"uuid": "03ab610d-cdc2-4e3e-9333-3355d230c63e", "name": "c4ca1ade-179d-432e-83aa-2c08fc697d4d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4644531671008476, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4817339405405778, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "73bc9f62-480f-46cf-afcd-8c5b94b12949", "name": "7a7f61eb-ff66-4592-b711-e8f68fb6f976", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "03ab610d-cdc2-4e3e-9333-3355d230c63e"}}}]}, {"uuid": "30737f1f-4319-4ba3-b143-efc491f42666", "name": "load_p1rlv16255_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04647fad-19dc-4ed8-8820-aa312674145c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "73bc9f62-480f-46cf-afcd-8c5b94b12949"}}}}, {"uuid": "4b23e311-7943-422d-8036-795d226c5056", "name": "4c2b9662-225b-4476-a820-ebea7dd6cd13_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4644531671008476, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4817339405405778, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9abfb742-8cbc-45c7-9c87-4371f7aaccb0", "name": "15e086d0-210c-410b-8705-47d18a32229a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4b23e311-7943-422d-8036-795d226c5056"}}}]}, {"uuid": "ed5cb148-e823-4091-ada6-468a35548c2b", "name": "load_p1rlv16255_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04647fad-19dc-4ed8-8820-aa312674145c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9abfb742-8cbc-45c7-9c87-4371f7aaccb0"}}}}, {"uuid": "b9206117-0529-4264-b73e-55b2500c05e3", "name": "ab5cd4c7-7ee7-4c21-8057-038063eaf9e2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8706127135667018, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16715860689265086, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5ea928af-bad6-4091-8dc7-75ba862f7511", "name": "bec19463-4229-4d6e-b63c-15a0450d2b4c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b9206117-0529-4264-b73e-55b2500c05e3"}}}]}, {"uuid": "7ef08658-1307-4121-8016-74f46feb38bd", "name": "load_p1rlv16256_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32a9302f-2d40-4c2a-bde9-e4039694fed7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5ea928af-bad6-4091-8dc7-75ba862f7511"}}}}, {"uuid": "4400e645-c15b-423d-a001-1fafe395d053", "name": "f9fdfbe0-2bf8-4b72-a366-e3da05e258ae_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8706127135667018, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16715860689265086, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dda8c1a5-525e-4364-af26-78e19424f467", "name": "d63cdbd6-502d-4681-99e2-a8eeb953b257", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4400e645-c15b-423d-a001-1fafe395d053"}}}]}, {"uuid": "cdeb8b48-47ad-4bf8-92c3-0363ebc6a782", "name": "load_p1rlv16256_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32a9302f-2d40-4c2a-bde9-e4039694fed7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dda8c1a5-525e-4364-af26-78e19424f467"}}}}, {"uuid": "beac4282-b4c7-4eb0-93de-2a41be630a43", "name": "925a2eb7-b2e0-46cc-b80b-bf4f2b8a93d5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5300176124233262, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6781680527999017, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d502673e-7dd3-45a6-a579-ffb9a55848f8", "name": "01ef29b7-8ff1-4800-936c-664779c361a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "beac4282-b4c7-4eb0-93de-2a41be630a43"}}}]}, {"uuid": "d28047d9-c03a-4972-8fc7-efa3a0ce86d9", "name": "load_p1rlv16257_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "935c99a6-bef6-4417-872c-0685011c440c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d502673e-7dd3-45a6-a579-ffb9a55848f8"}}}}, {"uuid": "994e5651-413a-4b97-a2b2-d5943a71cb58", "name": "828072ef-0a9d-4974-829c-5645d4bedae7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5300176124233262, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6781680527999017, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7ba5b6f2-9cab-41b0-a932-9d854bd3325b", "name": "a8b422ff-9d3e-4557-bdcd-773a89766f6f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "994e5651-413a-4b97-a2b2-d5943a71cb58"}}}]}, {"uuid": "2ba63650-a710-4e26-a30d-86e871c82e66", "name": "load_p1rlv16257_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "935c99a6-bef6-4417-872c-0685011c440c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7ba5b6f2-9cab-41b0-a932-9d854bd3325b"}}}}, {"uuid": "2f6b96cc-4721-4475-95e9-eaa8a0e85f03", "name": "63625f2b-020f-4476-9e1c-9d712ccdd87d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6722127407962883, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033140171384262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "811a9b5d-2a61-4b6c-a2e0-5ce107bc00b6", "name": "73230dbd-3733-4264-9aa6-d13e34b20755", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2f6b96cc-4721-4475-95e9-eaa8a0e85f03"}}}]}, {"uuid": "52ab00f6-292c-455d-bbba-80c1f0b5f91b", "name": "load_p1rlv16260_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdf35585-e2b3-4463-a6a8-acb352f25003"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "811a9b5d-2a61-4b6c-a2e0-5ce107bc00b6"}}}}, {"uuid": "c15b2547-d011-4db6-9d04-f1e717f0f08c", "name": "54f7a169-8b0d-47b2-8b14-27e16b6a261d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6722127407962883, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033140171384262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1af14652-b203-4f34-9074-6cdb51a10016", "name": "e9a088d2-69ef-4170-877b-8920df6b8e71", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c15b2547-d011-4db6-9d04-f1e717f0f08c"}}}]}, {"uuid": "2d908939-4308-4f5b-be72-53cc9f4d1d1e", "name": "load_p1rlv16260_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdf35585-e2b3-4463-a6a8-acb352f25003"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1af14652-b203-4f34-9074-6cdb51a10016"}}}}, {"uuid": "cc7c06ce-5557-4741-adbd-bc87cfa866a0", "name": "bb5a6a11-424e-401c-afe5-bd05c2743423_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2418080165747822, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43915934621283365, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e320a0b7-fe42-471c-8a89-4b6bdc6b5d40", "name": "362883ee-229b-4629-a632-6584f97529e5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cc7c06ce-5557-4741-adbd-bc87cfa866a0"}}}]}, {"uuid": "6842b389-cbce-4f73-840a-cc799b7336fa", "name": "load_p1rlv16261_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "978533ca-ef57-4cb6-9e7f-b3c6d1bbd7d5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e320a0b7-fe42-471c-8a89-4b6bdc6b5d40"}}}}, {"uuid": "f808bfb1-0f63-49a6-b4d7-84c408cf8403", "name": "2a7b63c6-3aa6-455e-acdc-a90973682fd4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2418080165747822, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43915934621283365, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "76000378-abb6-474c-b2ef-c9a5911ca0e0", "name": "0df3c89f-82a2-4420-9285-06a1a22b331f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f808bfb1-0f63-49a6-b4d7-84c408cf8403"}}}]}, {"uuid": "da0c47c7-3c79-431b-a175-2dcfd601d834", "name": "load_p1rlv16261_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "978533ca-ef57-4cb6-9e7f-b3c6d1bbd7d5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "76000378-abb6-474c-b2ef-c9a5911ca0e0"}}}}, {"uuid": "63fe4f3f-90de-445b-8136-d4cdd933eed8", "name": "3cffff74-ca06-4e9a-9232-7d0df38f01a8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3461402320099836, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.810674183062217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "97783810-fe85-49f2-b7b1-4af46cbb2455", "name": "3c85ce4a-02e0-4569-9661-7e6e18d6fcc6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "63fe4f3f-90de-445b-8136-d4cdd933eed8"}}}]}, {"uuid": "2478ec7b-45fe-451f-96aa-9cd41b6f9263", "name": "load_p1rlv16262_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2797febc-f5e7-4cb3-b26f-ace990dc6920"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "97783810-fe85-49f2-b7b1-4af46cbb2455"}}}}, {"uuid": "b5bd882c-07e7-4870-a1b0-72e8c0a74c42", "name": "ca1173a9-81dd-4995-b2c8-8be9f00d3b44_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3461402320099836, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.810674183062217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ad7e9c8c-0ea3-4832-aaef-b9d7c92f3ba2", "name": "0ddc8173-4d7f-46b0-91fa-215a138b9994", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5bd882c-07e7-4870-a1b0-72e8c0a74c42"}}}]}, {"uuid": "6dbd4747-2e7a-43d5-82c0-b479ca86714f", "name": "load_p1rlv16262_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2797febc-f5e7-4cb3-b26f-ace990dc6920"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ad7e9c8c-0ea3-4832-aaef-b9d7c92f3ba2"}}}}, {"uuid": "766c6dc0-d413-4dbb-a420-6b1533031cf2", "name": "7fb9e6ab-e824-4df2-a9cb-5005dcccf9b0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0052757727111112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4127143879372469, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9c4de1e6-0bd5-48b5-be95-30f7a4348c4a", "name": "a7c4d71c-995e-451f-a474-d0549dc2595b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "766c6dc0-d413-4dbb-a420-6b1533031cf2"}}}]}, {"uuid": "0219d6c8-98f6-4b98-ba29-a7464b82d3a0", "name": "load_p1rlv16266_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8835446-b333-4be9-96bd-57ff9d01ebd3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9c4de1e6-0bd5-48b5-be95-30f7a4348c4a"}}}}, {"uuid": "6dd6e2aa-1372-49e8-b910-cfe96b05329f", "name": "83b3b560-4487-470e-949c-4bba6d48ced2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0052757727111112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4127143879372469, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bfa003ca-bc4f-40f9-86c4-6a26450c4ff9", "name": "53a515c2-8ea2-459f-bea2-aca4afe2b4cc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6dd6e2aa-1372-49e8-b910-cfe96b05329f"}}}]}, {"uuid": "c786b4c3-1774-4050-8f6c-dc85c54dcd2e", "name": "load_p1rlv16266_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8835446-b333-4be9-96bd-57ff9d01ebd3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bfa003ca-bc4f-40f9-86c4-6a26450c4ff9"}}}}, {"uuid": "ac644023-aa22-402b-ace4-4f36a5673237", "name": "e670b296-ded9-440d-ab06-b3f8559514b0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.794005533851084, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6855099409421886, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "34c86588-a163-48ef-b08d-7eb6cef459c9", "name": "907ea48a-5646-4b42-92a1-dbb5541aa5db", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ac644023-aa22-402b-ace4-4f36a5673237"}}}]}, {"uuid": "499f83ff-6b0f-4a37-8418-a9a3cf315367", "name": "load_p1rlv16267_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19aeb510-ac0e-4279-8db0-8de282beccc8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "34c86588-a163-48ef-b08d-7eb6cef459c9"}}}}, {"uuid": "a80fc465-3c9d-438b-90e2-02ba863feea8", "name": "633da08d-3a5e-43ac-894b-3b2ccf0b86bf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.794005533851084, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6855099409421886, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "443427c2-6d12-4a22-b3d0-b408d981790a", "name": "17416c46-f23f-4b83-8ea4-a680905559b6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a80fc465-3c9d-438b-90e2-02ba863feea8"}}}]}, {"uuid": "127ee3f0-2b6f-46e0-953b-289dcd335a77", "name": "load_p1rlv16267_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19aeb510-ac0e-4279-8db0-8de282beccc8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "443427c2-6d12-4a22-b3d0-b408d981790a"}}}}, {"uuid": "fbe6e7b4-6025-4fac-b687-23e5575e10a1", "name": "44017a22-e3fc-440b-b8d4-7a098e0e770b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.996798907530164, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8717719006522443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a9e73675-bd7f-4896-a8ef-b46736678299", "name": "e6fc554d-c5a0-41bd-8cfc-9b4ea5d0a630", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fbe6e7b4-6025-4fac-b687-23e5575e10a1"}}}]}, {"uuid": "45761486-6e20-4090-94b4-f9d63478adc5", "name": "load_p1rlv16268_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba6ebe7f-b6b9-4f89-8bbf-7bffd63e10ef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a9e73675-bd7f-4896-a8ef-b46736678299"}}}}, {"uuid": "18caad4c-d890-448a-9ace-972ec6a6835f", "name": "5e667111-1000-4735-bc29-2f67e6a70057_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.996798907530164, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8717719006522443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dc1f1735-3f44-4f61-b875-f12cb02307da", "name": "a5de17ab-6886-4664-96b3-3b91edcb5728", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "18caad4c-d890-448a-9ace-972ec6a6835f"}}}]}, {"uuid": "ec9dbc63-2f0e-4689-9ab4-bc7d0fb48a81", "name": "load_p1rlv16268_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba6ebe7f-b6b9-4f89-8bbf-7bffd63e10ef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dc1f1735-3f44-4f61-b875-f12cb02307da"}}}}, {"uuid": "2bb55537-b3e1-4402-ae93-99f3cfc641a0", "name": "d8204634-e3fb-46cc-be88-bf688e8403ec_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.363798145332242, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4037116383567407, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "18b116f5-1ea8-404d-bac8-f2a3ef26b69b", "name": "f51befad-0132-4880-b571-049060304211", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2bb55537-b3e1-4402-ae93-99f3cfc641a0"}}}]}, {"uuid": "9bc29a80-f4ba-400b-b9d9-5db241d12b87", "name": "load_p1rlv16269_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc746539-662a-4fe4-8774-6ba2dc538118"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "18b116f5-1ea8-404d-bac8-f2a3ef26b69b"}}}}, {"uuid": "a9bcdd6a-962b-4507-947d-e42dd45d6fb1", "name": "90a80808-5225-4d5b-a3b3-22321a5f0a94_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.363798145332242, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4037116383567407, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d7b1fa47-0d96-46d5-b6cc-b9d9ecb31cec", "name": "f475d6a4-7e59-4bd1-a7d3-a45749669581", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a9bcdd6a-962b-4507-947d-e42dd45d6fb1"}}}]}, {"uuid": "4f175f3f-77a2-4b06-92d1-e3eae1b6a441", "name": "load_p1rlv16269_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc746539-662a-4fe4-8774-6ba2dc538118"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d7b1fa47-0d96-46d5-b6cc-b9d9ecb31cec"}}}}, {"uuid": "88028e8a-b39f-47f5-ae02-9827bed072f6", "name": "2a31ba10-cda3-4d2c-ad58-4118a881432a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.715296910036079, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.4546814180149177, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b8db8593-7b21-4054-b8b1-7e099912bdc2", "name": "89ed205c-4a38-46e9-afc3-163d886fe797", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "88028e8a-b39f-47f5-ae02-9827bed072f6"}}}]}, {"uuid": "858ffea9-e5e4-4ffc-9d42-b093f732e45a", "name": "load_p1rlv16270_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c620d4b9-a849-4bf6-b108-118836866602"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b8db8593-7b21-4054-b8b1-7e099912bdc2"}}}}, {"uuid": "4fb48713-2e5d-478a-8411-d43906004b3f", "name": "9fbcd029-fe06-4367-8b92-13840b382478_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.715296910036079, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.4546814180149177, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "453a6785-1ac8-404d-89d2-1428d14db38d", "name": "2ee690ab-de60-49c3-af76-f76b89005969", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4fb48713-2e5d-478a-8411-d43906004b3f"}}}]}, {"uuid": "ec15395f-4ea3-4a6d-92b1-88e1ec5f0d99", "name": "load_p1rlv16270_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c620d4b9-a849-4bf6-b108-118836866602"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "453a6785-1ac8-404d-89d2-1428d14db38d"}}}}, {"uuid": "5e911122-0db2-45dd-ac44-255e1ce2411c", "name": "03277084-12fe-4790-9668-fe8bb0eb03b1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.381399729703326, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.39528166539642545, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "32b235f2-0766-401f-8138-ad69dd2b6554", "name": "03277084-12fe-4790-9668-fe8bb0eb03b1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.381399729703326, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.39528166539642545, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fae6af08-41bc-4ece-913d-30dbceb3662d", "name": "03277084-12fe-4790-9668-fe8bb0eb03b1_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.381399729703326, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.39528166539642545, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "653f0d5d-08e0-47e1-a06d-715772f43c9d", "name": "8d7aafb3-8c0d-44f7-a78c-8cd67e83374a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5e911122-0db2-45dd-ac44-255e1ce2411c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "32b235f2-0766-401f-8138-ad69dd2b6554"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fae6af08-41bc-4ece-913d-30dbceb3662d"}}}]}, {"uuid": "d43dadee-e804-47c5-b631-82815e8ff5a5", "name": "load_p1rlv16271", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "606bf8f6-d745-4220-8cae-e01ffd22f669"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "653f0d5d-08e0-47e1-a06d-715772f43c9d"}}}}, {"uuid": "8ff3666a-1963-476c-b693-6e282e2a9e80", "name": "e2a47060-377d-427a-a38f-820686e5aa38_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.200687176070838, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9185981858680964, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f9123dcb-c7b3-422d-a8ea-8221e79caf63", "name": "0220b4c2-aa64-438f-ab3b-53e41f2f2d09", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ff3666a-1963-476c-b693-6e282e2a9e80"}}}]}, {"uuid": "031b5c59-2c52-4aec-8004-569f6c5a58d6", "name": "load_p1rlv16395_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d908890-4fe4-4349-92de-464c4165b185"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f9123dcb-c7b3-422d-a8ea-8221e79caf63"}}}}, {"uuid": "94238b3a-7fbf-4103-85a7-29eed43f218a", "name": "4e22a016-eb19-423a-bd1a-f2163e3af209_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.200687176070838, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9185981858680964, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "df08e771-7168-481a-ac9d-db1982a6beba", "name": "59f2bd06-7d04-442c-8ebd-4482658d2f47", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "94238b3a-7fbf-4103-85a7-29eed43f218a"}}}]}, {"uuid": "e193f5cd-04c5-410c-9bc1-24636b2ade55", "name": "load_p1rlv16395_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d908890-4fe4-4349-92de-464c4165b185"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "df08e771-7168-481a-ac9d-db1982a6beba"}}}}, {"uuid": "5e8f9a6c-45eb-41d2-a216-cdb7483ef44f", "name": "1566d76b-0145-466e-82c6-a75d0c430211_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.2106819008595595, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9283160881681002, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8c99023a-c460-4f29-b354-305ff8386f11", "name": "34e343f9-2dce-4c6f-9eea-d1134fa429fc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5e8f9a6c-45eb-41d2-a216-cdb7483ef44f"}}}]}, {"uuid": "78ba092a-6d63-42c4-9de8-782f0fe22265", "name": "load_p1rlv16397_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "323373a9-8e7d-4fb4-8970-dcc0e6d26c98"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8c99023a-c460-4f29-b354-305ff8386f11"}}}}, {"uuid": "63422d23-642b-4d3b-81af-4314d3fcd30a", "name": "7078de00-ecb8-4875-9964-76435221690b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.2106819008595595, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9283160881681002, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bb56652e-af5e-41f7-a9ee-946da3e3082c", "name": "98160b95-d28a-4371-a8da-a13f3b99df61", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "63422d23-642b-4d3b-81af-4314d3fcd30a"}}}]}, {"uuid": "fa96bddd-c21e-4501-99b6-78db3a2ca659", "name": "load_p1rlv16397_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "323373a9-8e7d-4fb4-8970-dcc0e6d26c98"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bb56652e-af5e-41f7-a9ee-946da3e3082c"}}}}, {"uuid": "e0b8d152-b240-434a-abe9-c4a70a2db003", "name": "38583533-e4ea-4249-8e7e-1c4ed998db82_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.920542613760824, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4990926315178331, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9e3961fc-f9f8-4891-951a-23e65d454092", "name": "a0ae2021-193a-4953-980f-f36acf97e0fd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e0b8d152-b240-434a-abe9-c4a70a2db003"}}}]}, {"uuid": "e4861e25-be6b-4ee7-8e99-6ede3986573d", "name": "load_p1rlv16401_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eeb598c2-f0b9-44df-bfaa-be66e4dc3920"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9e3961fc-f9f8-4891-951a-23e65d454092"}}}}, {"uuid": "3eb79a2e-5060-4dbc-9c72-5a4579c04793", "name": "5c536cf4-fa72-451d-be0d-a0e6fd1991be_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.920542613760824, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4990926315178331, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "895c87e5-e252-4913-a419-0644656b383d", "name": "62f3429e-8711-4c19-a7bb-3ce027f757a4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3eb79a2e-5060-4dbc-9c72-5a4579c04793"}}}]}, {"uuid": "a4fc401f-e024-44ee-bdbf-fce51a70f474", "name": "load_p1rlv16401_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eeb598c2-f0b9-44df-bfaa-be66e4dc3920"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "895c87e5-e252-4913-a419-0644656b383d"}}}}, {"uuid": "0cb39cce-8587-42be-8a63-ae3f59f5498a", "name": "eaf5cd82-120d-4055-93ae-a5c5fadd5609_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.747873943758341, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9398519580990949, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a7d066f-f450-4423-a697-67bfabe799b6", "name": "2e5625b0-4790-436b-8bf6-f13c9400d604", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0cb39cce-8587-42be-8a63-ae3f59f5498a"}}}]}, {"uuid": "972c7a59-6ae7-404e-81c7-fa45c57dfe21", "name": "load_p1rlv16412_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99f97a6b-4e94-4a35-ad00-12e7004ab5e3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0a7d066f-f450-4423-a697-67bfabe799b6"}}}}, {"uuid": "a8d982e1-2a2e-460e-883b-a181406ff941", "name": "9c75b838-e827-4110-a6bf-ef41c34de906_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.747873943758341, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9398519580990949, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dbaadde4-0d3c-44c0-b295-8e7e110e0148", "name": "1305a3ed-9851-45cb-8f23-09fdbd0d484b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a8d982e1-2a2e-460e-883b-a181406ff941"}}}]}, {"uuid": "71897fc9-f974-473a-8e44-b653f2d4c7c9", "name": "load_p1rlv16412_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99f97a6b-4e94-4a35-ad00-12e7004ab5e3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dbaadde4-0d3c-44c0-b295-8e7e110e0148"}}}}, {"uuid": "fb4a62a0-6b8b-4aa4-a292-412cd593e270", "name": "bd94fb3e-a911-4262-9c76-ea0664b61703_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9024769844937937, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4778358547008617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fd827a6d-018c-4b7a-bb2a-6ed130bd6e6e", "name": "59cdad1d-5b1e-4c9b-bfc1-512f9c41b5a2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fb4a62a0-6b8b-4aa4-a292-412cd593e270"}}}]}, {"uuid": "2ce8b856-2d26-4281-aaab-596c3aa921b1", "name": "load_p1rlv16416_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f58421d6-268b-417f-a579-c9c51d010697"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fd827a6d-018c-4b7a-bb2a-6ed130bd6e6e"}}}}, {"uuid": "39d86888-aaa7-4a94-b9ec-9444c822057c", "name": "c8dbd97e-f5f6-4daa-a313-2c40117c05c7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9024769844937937, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4778358547008617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "847117f1-9f81-41be-b42e-fd15caeb15e1", "name": "ef194679-6d04-4f0d-9bd6-d5cb958e0160", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "39d86888-aaa7-4a94-b9ec-9444c822057c"}}}]}, {"uuid": "144a5cf3-f2a4-499f-8c1d-a996c5975237", "name": "load_p1rlv16416_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f58421d6-268b-417f-a579-c9c51d010697"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "847117f1-9f81-41be-b42e-fd15caeb15e1"}}}}, {"uuid": "b5b3d6cf-cf26-41b1-92fa-2c00a700f522", "name": "e3c3d445-ec7d-4307-a035-29b44e2cffc9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.100297733607771, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.379845362785626, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "48234896-3c26-4383-bf9c-7bb1d6ccc698", "name": "d661ec93-2b74-4ca4-acae-c25a38675b40", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5b3d6cf-cf26-41b1-92fa-2c00a700f522"}}}]}, {"uuid": "50b75eea-371d-414e-84a7-a37d6213dc2f", "name": "load_p1rlv16422_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f367b63c-c4cb-4810-a270-8bd0153b7b32"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "48234896-3c26-4383-bf9c-7bb1d6ccc698"}}}}, {"uuid": "f76aa752-5d3c-4be3-8a2d-1fabc5243c2c", "name": "674f99af-8538-4b59-ab83-3a7769bc1e72_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.100297733607771, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.379845362785626, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7cfa42c3-e840-422f-80a5-74b8ec5dde7b", "name": "da5a56e2-0034-4629-8766-d31f5dbcf160", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f76aa752-5d3c-4be3-8a2d-1fabc5243c2c"}}}]}, {"uuid": "84ee1d2a-1808-4c42-b6ba-45fe48465d3e", "name": "load_p1rlv16422_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f367b63c-c4cb-4810-a270-8bd0153b7b32"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7cfa42c3-e840-422f-80a5-74b8ec5dde7b"}}}}, {"uuid": "acb00d95-db2f-40e8-beb1-a4e8a45da78d", "name": "b4cdad6e-5ab2-4a57-ab7e-e4f723888a64_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7146312183983485, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.11264482158049681, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "be571320-8f57-4664-9bb6-d56b2d52f5a2", "name": "13c3ce49-f12c-4cf8-bdad-35c19c524a2a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "acb00d95-db2f-40e8-beb1-a4e8a45da78d"}}}]}, {"uuid": "545bdbcc-1bb9-4d47-88c5-63387a19ba86", "name": "load_p1rlv16424_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2242f1c-542f-4c1f-b3e6-19482cccde8d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "be571320-8f57-4664-9bb6-d56b2d52f5a2"}}}}, {"uuid": "ddbcc4d0-063e-42c3-aed6-33dbcc9717b4", "name": "6301a0e2-3050-41f1-82f2-e9b469ea8890_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7146312183983485, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.11264482158049681, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "de5e16e3-2362-49da-8da5-dd4fab6e1d8f", "name": "a907226d-90ca-4a98-b898-33882224f3d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ddbcc4d0-063e-42c3-aed6-33dbcc9717b4"}}}]}, {"uuid": "ca76d76a-35c5-4ce5-bb21-a6c2111d97f8", "name": "load_p1rlv16424_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2242f1c-542f-4c1f-b3e6-19482cccde8d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "de5e16e3-2362-49da-8da5-dd4fab6e1d8f"}}}}, {"uuid": "0957b252-5e47-41f7-b6a2-e6577b17d3ce", "name": "bc925ba2-7d8a-4708-b132-5ece3fa00e87_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.793928923123666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.7667648924934154, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "60d2dcc2-e172-4041-abfb-5298882919e7", "name": "5d0b074a-5d1c-4241-a268-95c5b2571918", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0957b252-5e47-41f7-b6a2-e6577b17d3ce"}}}]}, {"uuid": "ed7f906d-4b9f-4f83-8d0a-58f61acbdb93", "name": "load_p1rlv16445_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e090544-3c8e-4716-9dae-0b311a1017ea"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "60d2dcc2-e172-4041-abfb-5298882919e7"}}}}, {"uuid": "883d160b-99e7-4ffd-8b68-43ee7cb47fea", "name": "4426ee03-4e04-42bf-93e1-5f2e1c49824f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.793928923123666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.7667648924934154, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "55dfe357-873c-47e5-ab06-37d5c04becd5", "name": "921d10ba-5e6b-49f7-b86e-1cd9aa75fb05", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "883d160b-99e7-4ffd-8b68-43ee7cb47fea"}}}]}, {"uuid": "1e183d4f-b8fd-497d-a0ad-f733ce506ce7", "name": "load_p1rlv16445_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e090544-3c8e-4716-9dae-0b311a1017ea"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "55dfe357-873c-47e5-ab06-37d5c04becd5"}}}}, {"uuid": "5a211146-e012-456c-acc9-8cc008eca9a0", "name": "3e340988-092c-4bf0-884c-e6848c72bdba_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5124251878637117, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2529156883724651, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "23ee6240-dfad-4b00-9260-13fe18d5afeb", "name": "c47a35b0-fcfc-44d7-ad74-1fce01a4fee3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5a211146-e012-456c-acc9-8cc008eca9a0"}}}]}, {"uuid": "f8f20623-08e0-49eb-8fd4-80a55e1449e2", "name": "load_p1rlv16570_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53d578d8-8492-471b-8f66-233e489a3652"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "23ee6240-dfad-4b00-9260-13fe18d5afeb"}}}}, {"uuid": "e6193a80-06aa-4c97-bb3a-f13e1fa7f569", "name": "2e814c98-0b7a-40b2-bfd4-cfbb60c0e567_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5124251878637117, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2529156883724651, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d87b565f-a5cf-4cb5-ac56-00d16fe1fba6", "name": "806e10c4-878d-48c1-b69f-077aed7b90ab", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e6193a80-06aa-4c97-bb3a-f13e1fa7f569"}}}]}, {"uuid": "8c31522e-cd10-4472-9fa2-5b897e757d1c", "name": "load_p1rlv16570_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53d578d8-8492-471b-8f66-233e489a3652"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d87b565f-a5cf-4cb5-ac56-00d16fe1fba6"}}}}, {"uuid": "4306f62f-dad2-4a33-bc8d-b31aaa97026e", "name": "1ab8d14c-2283-4cd0-ba17-80293c683a51_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9337862827800336, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34425772205755256, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cb6a0dc7-444c-4267-956a-8b9390366a6c", "name": "ad737204-4fee-40ca-a2c2-99bd4fb6f4d0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4306f62f-dad2-4a33-bc8d-b31aaa97026e"}}}]}, {"uuid": "13635ed1-a73b-4dc9-994c-9462be78e2f2", "name": "load_p1rlv16882_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4faf40b9-9ade-45b5-ade8-3f1833605cd1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cb6a0dc7-444c-4267-956a-8b9390366a6c"}}}}, {"uuid": "5bcd5511-2529-4eb7-8457-f438d0ac891c", "name": "11edd1eb-b4c5-453c-88e0-6f85e656d400_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9337862827800336, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34425772205755256, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bedbef98-fe52-4764-884c-77bb39d1915b", "name": "2d845e5b-b7bc-441a-80ac-faf2ef20b6fa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5bcd5511-2529-4eb7-8457-f438d0ac891c"}}}]}, {"uuid": "fe9e25b6-5829-4ee2-95d3-fc3be395fe81", "name": "load_p1rlv16882_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4faf40b9-9ade-45b5-ade8-3f1833605cd1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bedbef98-fe52-4764-884c-77bb39d1915b"}}}}, {"uuid": "67097ee4-b9be-4d31-9082-f7cf66ee0049", "name": "7e3c2e38-0f54-4726-8760-d92e4426f3d5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7142625617629952, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4166771141877461, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "14d97bf2-c194-4d47-a769-752dcc747f0f", "name": "5a6eaf75-f71b-43c8-ac57-516d27edcc59", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "67097ee4-b9be-4d31-9082-f7cf66ee0049"}}}]}, {"uuid": "8b5cf97f-791d-48cb-ad48-c2d8996a3bb1", "name": "load_p1rlv16904_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c570ef7-c483-4c1e-b0fd-8712e8e9a7cd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "14d97bf2-c194-4d47-a769-752dcc747f0f"}}}}, {"uuid": "e4e83eb7-f622-4640-af52-46e1d50e9da0", "name": "9a014efa-0f29-42bb-aca3-cb1ecfc50a01_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7142625617629952, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4166771141877461, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8af8e30a-1df0-4b5e-a815-a5afb6dbceb1", "name": "4e8548d9-9864-4a11-ae5f-66f3b465cc8b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e4e83eb7-f622-4640-af52-46e1d50e9da0"}}}]}, {"uuid": "857cf48e-9845-4a5a-bf80-2ceb844a67c1", "name": "load_p1rlv16904_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c570ef7-c483-4c1e-b0fd-8712e8e9a7cd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8af8e30a-1df0-4b5e-a815-a5afb6dbceb1"}}}}, {"uuid": "df222f2e-23dd-468f-abac-32289594b03b", "name": "f655d0ce-0bc4-45c4-bb49-ab4042a2ba9e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9815403167210675, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24442739866112323, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bc3ab1a5-9b77-46b0-9f7c-253a91bd57d3", "name": "bae5a9cd-a7ea-4ee4-9283-9944acb0cd4d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "df222f2e-23dd-468f-abac-32289594b03b"}}}]}, {"uuid": "d4a1993f-3687-4bac-b090-3ff6435c1d4e", "name": "load_p1rlv16905_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7578563f-d4b3-423b-a8f5-3ee91a042d19"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bc3ab1a5-9b77-46b0-9f7c-253a91bd57d3"}}}}, {"uuid": "fa94f8b3-d59f-46a5-a6bb-e9b83759f5cc", "name": "b3c28b6d-786a-4772-9800-eea955d5fc28_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9815403167210675, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24442739866112323, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "694a5d1c-d56c-47f4-b69f-6da3db4ec8cb", "name": "8f57c6a1-5078-4d04-9e2a-232279038f1a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fa94f8b3-d59f-46a5-a6bb-e9b83759f5cc"}}}]}, {"uuid": "a91940b7-1c3f-47c8-93b0-e337ac5fb2d4", "name": "load_p1rlv16905_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7578563f-d4b3-423b-a8f5-3ee91a042d19"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "694a5d1c-d56c-47f4-b69f-6da3db4ec8cb"}}}}, {"uuid": "866ee746-a9bb-4d9c-ac8d-b42925c2c936", "name": "16d64a28-9219-4b9e-8f02-0912ba526235_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1343287185333217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10429894918818222, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d281b117-2cfb-4d45-8fed-08e1d7ffcf94", "name": "a81c35a6-347a-4126-a0e4-f8d300079da2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "866ee746-a9bb-4d9c-ac8d-b42925c2c936"}}}]}, {"uuid": "ad5a7f1b-50a3-44c6-9f2c-ea3d4ba82a5c", "name": "load_p1rlv16912_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2308dc3-d10b-4049-862d-caf3356fa9a7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d281b117-2cfb-4d45-8fed-08e1d7ffcf94"}}}}, {"uuid": "44ebafdb-92a3-4071-b231-b704f0339e29", "name": "3a39d6e5-1381-45d2-a9fc-0ad7b0f1f80f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1343287185333217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10429894918818222, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "185703fc-cf0d-4f5b-b80f-56147a287127", "name": "952ebf46-a3d9-4ca9-b4e1-f01b4ce8a248", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "44ebafdb-92a3-4071-b231-b704f0339e29"}}}]}, {"uuid": "fd6e366d-3ed9-4ed3-ad86-5d5dab393117", "name": "load_p1rlv16912_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2308dc3-d10b-4049-862d-caf3356fa9a7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "185703fc-cf0d-4f5b-b80f-56147a287127"}}}}, {"uuid": "73edb9fc-934c-47f0-9015-56196051abfa", "name": "b74a2985-70da-447e-8ac4-c0bd47dea132_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2143639459232007, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7122713279236396, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4710cb21-5f36-4516-ac1e-c0d9f0c0ef39", "name": "53f178ef-52ba-47fa-b976-d30d5d10ccbe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "73edb9fc-934c-47f0-9015-56196051abfa"}}}]}, {"uuid": "43230887-62aa-439a-85e3-abc02603d949", "name": "load_p1rlv16919_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07e01053-37f3-4b9f-a9f1-d51bccd29803"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4710cb21-5f36-4516-ac1e-c0d9f0c0ef39"}}}}, {"uuid": "86d6c8a3-2319-4a32-a922-c9ac44d610dd", "name": "318b9101-6f0f-4353-b5c1-8a27537eef2b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2143639459232007, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7122713279236396, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "919cfc31-0be3-4208-bf84-58b3309fc292", "name": "1b4463c8-f9b7-4cfb-90a3-709b2892605d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "86d6c8a3-2319-4a32-a922-c9ac44d610dd"}}}]}, {"uuid": "a3d23238-a2d4-4e9e-8634-ebbb3d8e4a49", "name": "load_p1rlv16919_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07e01053-37f3-4b9f-a9f1-d51bccd29803"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "919cfc31-0be3-4208-bf84-58b3309fc292"}}}}, {"uuid": "90d19537-202e-4e99-9cdf-927be743f348", "name": "7f3a53b7-4837-4378-a8e1-fc886f275bc3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.639612501586281, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0977377571892493, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ae8b7549-b9c4-42b7-b6aa-eecd7bb1aa64", "name": "c645099e-0bfa-4f86-a6b3-d9b7c7a32c74", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "90d19537-202e-4e99-9cdf-927be743f348"}}}]}, {"uuid": "357d6e7d-d014-4950-8144-fd7502b9f6de", "name": "load_p1rlv16922_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce315d98-1556-429b-aebb-0c868892396a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ae8b7549-b9c4-42b7-b6aa-eecd7bb1aa64"}}}}, {"uuid": "f035a725-f539-40d0-b933-6da8edcb77d5", "name": "d0cf8fdd-fa68-49a4-8977-cf240c7ad71d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.639612501586281, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0977377571892493, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e643043d-ffbf-476a-ac58-ece88d41d61b", "name": "b31151a5-91b8-4e1d-93b7-31bbd6026038", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f035a725-f539-40d0-b933-6da8edcb77d5"}}}]}, {"uuid": "b40d9973-ff90-40bc-81dc-47776eb3ec4d", "name": "load_p1rlv16922_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce315d98-1556-429b-aebb-0c868892396a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e643043d-ffbf-476a-ac58-ece88d41d61b"}}}}, {"uuid": "269e746a-750e-4682-a328-d6112a6b4c81", "name": "a1e2c112-06a4-43cd-8c40-d406276e9962_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8791002615066037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24190904367644575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d77d41b1-5754-48bd-a7e9-50f52f40292b", "name": "94f922d3-6550-4f04-a21f-e2607de92a1a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "269e746a-750e-4682-a328-d6112a6b4c81"}}}]}, {"uuid": "3bf281d4-9ac9-4acf-9a5b-40552c83d5aa", "name": "load_p1rlv16926_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ba1d053-4462-4eb4-aca6-5ede38aa283c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d77d41b1-5754-48bd-a7e9-50f52f40292b"}}}}, {"uuid": "c1f34f7a-2f15-42c3-b742-defc4351a6d7", "name": "e8c1986b-032b-42ac-970b-c9e7d2f39d4f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8791002615066037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24190904367644575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8e73e7fb-0082-427b-bd92-3eab59da11f8", "name": "3b75e35b-133f-42a5-959b-c9303ca23409", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c1f34f7a-2f15-42c3-b742-defc4351a6d7"}}}]}, {"uuid": "c6019ae8-df4a-41f0-97a2-855d85873f24", "name": "load_p1rlv16926_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ba1d053-4462-4eb4-aca6-5ede38aa283c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8e73e7fb-0082-427b-bd92-3eab59da11f8"}}}}, {"uuid": "e4798d07-13c7-4501-b729-ce5eda382096", "name": "78e0bede-b943-41f4-bae9-36cc1b941ed1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.618088489787842, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20923793518521916, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c1a46fd4-dc1f-4a50-921e-34cb0e661c0a", "name": "a477015b-a6b4-4d59-8118-6409d2d5163a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e4798d07-13c7-4501-b729-ce5eda382096"}}}]}, {"uuid": "d25e070f-7ee8-4373-901d-635190d93b31", "name": "load_p1rlv16957_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7dff1455-5154-429f-a33f-044d8501281d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c1a46fd4-dc1f-4a50-921e-34cb0e661c0a"}}}}, {"uuid": "f4578af1-d2ff-4d34-aeb0-e1f28782f43a", "name": "a8087e06-51a4-4993-be20-3a0a57beb633_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.618088489787842, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20923793518521916, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9318be11-995a-4a84-8c1b-fdec953d1314", "name": "bc987390-8d02-46bb-96c3-abc5e3303f43", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f4578af1-d2ff-4d34-aeb0-e1f28782f43a"}}}]}, {"uuid": "b2bfe792-092e-441f-9a3f-1dc753a5797c", "name": "load_p1rlv16957_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7dff1455-5154-429f-a33f-044d8501281d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9318be11-995a-4a84-8c1b-fdec953d1314"}}}}, {"uuid": "820bf4c1-a84c-44fc-bc19-11ed37eede7a", "name": "b21a5757-7bac-4856-9a9c-fc91a7957da8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.625738069985529, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4783299291729874, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ae2df8a9-90b4-4937-8ba7-7d29299cf81a", "name": "1bbaf78b-e251-4fb1-b435-eeb6c539182c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "820bf4c1-a84c-44fc-bc19-11ed37eede7a"}}}]}, {"uuid": "c8dc1e85-f14e-49ac-8c5b-575e8bd62139", "name": "load_p1rlv16988_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11a633b0-2b09-4c66-94d4-d1c24cdd9cf5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ae2df8a9-90b4-4937-8ba7-7d29299cf81a"}}}}, {"uuid": "4fa90c01-ad5c-46ea-9b67-f1f85fb22042", "name": "63dc0f2c-4e69-4774-ae09-76780325d50b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.625738069985529, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4783299291729874, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ce4e0397-bcde-4b5f-8f7d-ce18e8885f2f", "name": "97149d3e-e2d8-419c-be96-c1abb64771c0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4fa90c01-ad5c-46ea-9b67-f1f85fb22042"}}}]}, {"uuid": "7a3dccae-2afa-4b23-b00a-910ae9ee1e94", "name": "load_p1rlv16988_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11a633b0-2b09-4c66-94d4-d1c24cdd9cf5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ce4e0397-bcde-4b5f-8f7d-ce18e8885f2f"}}}}, {"uuid": "4e5f4c5a-680a-4f82-9034-36b07c8af7df", "name": "b885c838-d5dd-401e-ab5b-f72e6a9b3074_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.857442654178314, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2722739314206026, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "70e96277-938a-41c9-872a-8953540c78f5", "name": "ea7d936e-d128-4341-a104-320475c1e68b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4e5f4c5a-680a-4f82-9034-36b07c8af7df"}}}]}, {"uuid": "0779aa7d-23e6-469b-bb88-25f2c5129f2f", "name": "load_p1rlv16992_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57e8aa34-3967-4f22-a978-cb513c49c153"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "70e96277-938a-41c9-872a-8953540c78f5"}}}}, {"uuid": "06636b1d-a342-42c8-8bd7-c49a0ab471d8", "name": "166da0d3-69b9-4e6c-90d7-1000d285d483_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.857442654178314, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2722739314206026, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "518e716f-a60e-4234-b173-d798f3671506", "name": "ab9fd947-c1b8-4877-a6eb-1c2f4401f41f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "06636b1d-a342-42c8-8bd7-c49a0ab471d8"}}}]}, {"uuid": "5bc1200b-19a4-4abd-ba8a-00031764829e", "name": "load_p1rlv16992_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57e8aa34-3967-4f22-a978-cb513c49c153"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "518e716f-a60e-4234-b173-d798f3671506"}}}}, {"uuid": "611fc267-7aa7-4bd8-8a31-aa63454e8e6c", "name": "fc502c9f-1d0c-4059-8f4c-88cd04fc680a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.5934418714018275, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3543697694181257, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "226fb417-254c-4e53-a5be-e88fa31856ff", "name": "0f9c2336-ba2c-4fe5-a661-2f9548ed1a65", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "611fc267-7aa7-4bd8-8a31-aa63454e8e6c"}}}]}, {"uuid": "7d3dd409-551e-4f07-a551-c0f615947d75", "name": "load_p1rlv17001_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f23214ee-3032-4403-9084-8117e89cb1cf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "226fb417-254c-4e53-a5be-e88fa31856ff"}}}}, {"uuid": "5c9d54af-9d15-445e-a04b-4b145ad9f1d8", "name": "5b9f9520-e11b-4645-b326-179d276830e7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.5934418714018275, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3543697694181257, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "30f29dcc-36bf-448b-8a1a-d8548da4f9ad", "name": "28b1e0c3-9834-405c-a87f-2705fc391994", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5c9d54af-9d15-445e-a04b-4b145ad9f1d8"}}}]}, {"uuid": "0310305e-5c68-4087-9f9c-31846d771f30", "name": "load_p1rlv17001_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f23214ee-3032-4403-9084-8117e89cb1cf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "30f29dcc-36bf-448b-8a1a-d8548da4f9ad"}}}}, {"uuid": "df4178c3-55ce-4da9-9e72-0d46e025bcfb", "name": "f7ccd451-931b-4ad7-86d7-540ffdf4d7f1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4585094523583652, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.19519922093662737, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "05dbd0b9-81d8-43a3-8b26-a8d014421a8e", "name": "e289882a-20f6-4105-93ed-2b41595bc8e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "df4178c3-55ce-4da9-9e72-0d46e025bcfb"}}}]}, {"uuid": "c7872ad2-77a0-4783-a58a-0014484bc2fd", "name": "load_p1rlv17028_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "213e6d98-ad57-4034-b2d0-4b096554cac2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "05dbd0b9-81d8-43a3-8b26-a8d014421a8e"}}}}, {"uuid": "9691ae32-fcce-4a5d-b7f9-2e0fd069df12", "name": "990c2f2a-51fa-4f7e-9be8-63cd80dfc8eb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4585094523583652, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.19519922093662737, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f5dbb8ee-a3ac-45d5-8565-cb868d8dcacc", "name": "2e596eab-4423-44c3-bfcd-fe7eab956605", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9691ae32-fcce-4a5d-b7f9-2e0fd069df12"}}}]}, {"uuid": "5118ee7c-01df-439c-8062-4621c59ad19d", "name": "load_p1rlv17028_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "213e6d98-ad57-4034-b2d0-4b096554cac2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f5dbb8ee-a3ac-45d5-8565-cb868d8dcacc"}}}}, {"uuid": "1075be6b-e219-473d-9788-5f8402ae986e", "name": "bc79087e-5b48-4f36-9565-0f6d889bf24a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3439175585507637, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8866404836608991, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b96068ac-8105-447b-87cc-d2dcd76627e9", "name": "c457924a-fe6c-41c2-8832-7e0dc9f8d167", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1075be6b-e219-473d-9788-5f8402ae986e"}}}]}, {"uuid": "de3a713a-805a-4f59-becb-1cf5a6bbf5bc", "name": "load_p1rlv17033_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfa28657-cd8e-4700-a189-83e021f77bee"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b96068ac-8105-447b-87cc-d2dcd76627e9"}}}}, {"uuid": "2b1955b1-62bc-4564-8fe6-35dd39d88f5b", "name": "aa89ade7-79fb-43ce-8080-59b9f57aaa03_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3439175585507637, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8866404836608991, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7b42fd45-8da2-44d9-8b3e-fcb8e439a5d7", "name": "c8b90da3-b732-4357-bb28-78406c91eb32", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2b1955b1-62bc-4564-8fe6-35dd39d88f5b"}}}]}, {"uuid": "abb1148b-4003-47e2-ac8c-b32e08454fca", "name": "load_p1rlv17033_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfa28657-cd8e-4700-a189-83e021f77bee"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7b42fd45-8da2-44d9-8b3e-fcb8e439a5d7"}}}}, {"uuid": "17e5dbaa-c769-4f03-b356-192bf295035c", "name": "191cfe11-c72d-45aa-a247-60bed4ebb772_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7956093485713416, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7629429667228578, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d53f386f-2df8-408d-9e51-aff2cce29ac9", "name": "e265aef2-bb12-431c-92b3-2353267e0ac9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "17e5dbaa-c769-4f03-b356-192bf295035c"}}}]}, {"uuid": "1002f375-c3f6-45cf-b9b1-cc1a38a48e60", "name": "load_p1rlv17059_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "92aff718-b70f-4ea4-b38b-fae69a470c58"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d53f386f-2df8-408d-9e51-aff2cce29ac9"}}}}, {"uuid": "f94714fc-b314-4c3b-a711-f8834d368c24", "name": "dc84c758-bc43-4d6e-8462-d0abdf0f5e91_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7956093485713416, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7629429667228578, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "845cf96b-513d-4834-8ba3-17f15390fbea", "name": "c47f2ca8-56e9-4890-bbe9-6a4ddf9cf345", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f94714fc-b314-4c3b-a711-f8834d368c24"}}}]}, {"uuid": "ffdaa977-c02b-4879-b639-18cc117150d5", "name": "load_p1rlv17059_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "92aff718-b70f-4ea4-b38b-fae69a470c58"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "845cf96b-513d-4834-8ba3-17f15390fbea"}}}}, {"uuid": "770ec631-db34-4b22-a286-0fe45386701a", "name": "352c6d36-cef7-4877-a5a5-ec706ac1b8aa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.969457727539003, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.134389471891055, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "70d017a7-e7af-4d32-a9ae-897881641612", "name": "02b55e58-5a28-4d94-be7a-8c095ffa4eb6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "770ec631-db34-4b22-a286-0fe45386701a"}}}]}, {"uuid": "d95d2f6f-c70e-4459-a852-b572c68f28be", "name": "load_p1rlv17063_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19130741-0fe1-4a12-8a55-96355609bccb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "70d017a7-e7af-4d32-a9ae-897881641612"}}}}, {"uuid": "e6f2358b-ab56-4521-bcd1-15842e7b60ed", "name": "e79d1d03-c7e9-4c3b-b406-1223c85893ee_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.969457727539003, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.134389471891055, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a79830b3-943c-443d-a83d-447940d123f8", "name": "a4593dd7-d942-489a-8b71-eb99f9f1c908", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e6f2358b-ab56-4521-bcd1-15842e7b60ed"}}}]}, {"uuid": "bd0c6050-31cd-4e76-be8f-e483919759fd", "name": "load_p1rlv17063_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19130741-0fe1-4a12-8a55-96355609bccb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a79830b3-943c-443d-a83d-447940d123f8"}}}}, {"uuid": "33fe1973-a21a-4bc8-a818-d2c6639e7533", "name": "714f5256-64f5-4ab0-9b88-7cc020a3ccc9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.922263051512463, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2402658775286277, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a2d73a08-0e8b-4a47-a01e-a4f6632a470b", "name": "c2a74168-1a0f-4204-b165-0b081563d7b0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "33fe1973-a21a-4bc8-a818-d2c6639e7533"}}}]}, {"uuid": "f7903183-a52b-4683-8bad-4d0773ce9007", "name": "load_p1rlv17069_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd48a076-5f8f-426a-b294-183700d1a123"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a2d73a08-0e8b-4a47-a01e-a4f6632a470b"}}}}, {"uuid": "4c5af2eb-8b35-4734-9ad2-817b3ccb6d3b", "name": "70c41a48-a083-4243-ab1d-5fd668ee1edb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.922263051512463, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2402658775286277, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5a08b7b6-26cd-4f5b-a3ef-7ad7476b292e", "name": "f6d0aaa9-95e7-47e3-bf15-8b5ba3ce733e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4c5af2eb-8b35-4734-9ad2-817b3ccb6d3b"}}}]}, {"uuid": "f578c8c4-fa8b-4d9e-9f07-4c804ebfbc3f", "name": "load_p1rlv17069_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd48a076-5f8f-426a-b294-183700d1a123"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5a08b7b6-26cd-4f5b-a3ef-7ad7476b292e"}}}}, {"uuid": "51f7d4f2-a266-4996-b80f-15338891adf1", "name": "1d06895b-42d8-4db3-8829-f756b36c3c76_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5365841293045384, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.535303100231416, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a0d7f2db-b0fe-45ca-8542-f5eedcbeab49", "name": "9de10aa4-24d6-4bf3-9b8a-57d7aa0b9870", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "51f7d4f2-a266-4996-b80f-15338891adf1"}}}]}, {"uuid": "c9d48c81-6c8c-490f-95dd-1ce2d8a0ae45", "name": "load_p1rlv17106_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5439f343-8176-4d92-99d4-bb9209817f6b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a0d7f2db-b0fe-45ca-8542-f5eedcbeab49"}}}}, {"uuid": "20a98f1d-cf86-4461-a79d-c2dc156064c9", "name": "21ab1c11-8243-4bec-8fd0-3e7c7fd1de67_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5365841293045384, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.535303100231416, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6d94ddb0-3dbb-4efe-acff-dfb997f912cd", "name": "12fe9e74-038d-4364-9813-9f3e5ad55a03", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "20a98f1d-cf86-4461-a79d-c2dc156064c9"}}}]}, {"uuid": "50ad8a88-7520-4cdc-ba7d-ff0d57068c1c", "name": "load_p1rlv17106_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5439f343-8176-4d92-99d4-bb9209817f6b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6d94ddb0-3dbb-4efe-acff-dfb997f912cd"}}}}, {"uuid": "8b36242e-6bd4-47a0-9b19-7bb52e4578f9", "name": "9cb374a1-06ea-4585-bed0-445caf08d05e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2874196130666418, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9219654181970236, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f6e11f36-1899-48eb-96e7-39b8e13aa53b", "name": "f1c45f95-14b0-4fe5-9278-4a588750554a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8b36242e-6bd4-47a0-9b19-7bb52e4578f9"}}}]}, {"uuid": "565a8900-809c-4de8-b22c-475b29b2a605", "name": "load_p1rlv17319_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9778ed5-f0c0-44de-b0d4-60659a54fa3b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f6e11f36-1899-48eb-96e7-39b8e13aa53b"}}}}, {"uuid": "ec253a61-eec6-4c57-9c65-7249402675e7", "name": "e5099b75-2916-449c-8052-583f32c20b53_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2874196130666418, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9219654181970236, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e1f66be1-8a64-4033-a446-a9cc4fd4d9c6", "name": "70dce794-59c9-46b4-a978-c63bcdd5170d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ec253a61-eec6-4c57-9c65-7249402675e7"}}}]}, {"uuid": "cf9a64fa-bfdf-49fd-9f95-5e01a1c9fb3b", "name": "load_p1rlv17319_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9778ed5-f0c0-44de-b0d4-60659a54fa3b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e1f66be1-8a64-4033-a446-a9cc4fd4d9c6"}}}}, {"uuid": "09753040-0e6b-4a7d-a2b7-32b34a52ae43", "name": "2c09bf7e-ea77-4ef0-8287-7831413ec4c3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.685213211371405, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7584354740780123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a6a57f47-e0a0-4271-bb83-ecadd10e445b", "name": "114d8058-bcfa-4ee0-b269-3af3608c887d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "09753040-0e6b-4a7d-a2b7-32b34a52ae43"}}}]}, {"uuid": "b8cc302b-3bc8-4b2e-8269-f92fa01fa7c1", "name": "load_p1rlv17320_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79991b02-c0f1-4b9b-a55e-e9b4ff7c17d9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a6a57f47-e0a0-4271-bb83-ecadd10e445b"}}}}, {"uuid": "1339bbd1-699a-457b-86a0-9548e35bffc5", "name": "448ee8a0-22e7-4fe1-803c-4b11107f1619_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.685213211371405, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7584354740780123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "657035af-f4c6-4e4a-9f57-3089797e7891", "name": "2b655e73-8a0e-402c-984b-80f6099048e2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1339bbd1-699a-457b-86a0-9548e35bffc5"}}}]}, {"uuid": "c7144a5c-c9bb-4a10-bd62-2874b0420620", "name": "load_p1rlv17320_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79991b02-c0f1-4b9b-a55e-e9b4ff7c17d9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "657035af-f4c6-4e4a-9f57-3089797e7891"}}}}, {"uuid": "d4da6f6f-0243-45bf-93a6-017baa6f7913", "name": "f760ccd8-5c94-4f50-b4f4-915c44375080_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.651721747239447, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.750976002130125, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0837056c-39b6-4fdb-8d38-7dbdb9184762", "name": "df662db3-42c8-4c75-8d37-5391bef3944e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d4da6f6f-0243-45bf-93a6-017baa6f7913"}}}]}, {"uuid": "239d1bff-f9a1-4edc-bc72-e064e2f577c4", "name": "load_p1rlv17321_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce41ac7c-06c5-435a-957d-c9dda83c1893"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0837056c-39b6-4fdb-8d38-7dbdb9184762"}}}}, {"uuid": "37295526-b584-45ad-92f9-39939c9a4ebf", "name": "a74f6ab6-e8f9-4028-8cf2-8b6085846259_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.651721747239447, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.750976002130125, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c7f44cb0-11c8-4f88-9771-59efe5287350", "name": "e5470d52-e1cb-4b55-973e-749cfe5b1e86", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "37295526-b584-45ad-92f9-39939c9a4ebf"}}}]}, {"uuid": "1b3480aa-cbb6-4442-a899-573ac7b41435", "name": "load_p1rlv17321_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce41ac7c-06c5-435a-957d-c9dda83c1893"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c7f44cb0-11c8-4f88-9771-59efe5287350"}}}}, {"uuid": "235d75c4-2295-44ab-8df0-5cd891f92385", "name": "7e97fd9b-b041-41f6-ae16-1532d47e3390_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.737986692242784, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8906640815201406, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "903aae3b-fcbc-44bf-8758-2d1c89fe8b18", "name": "61bd174e-2446-48ac-a280-97adb323c08d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "235d75c4-2295-44ab-8df0-5cd891f92385"}}}]}, {"uuid": "1535ffaa-5001-4f52-8f80-2852bafe92ad", "name": "load_p1rlv17325_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b96606c-9336-4299-be8d-295c84943a9d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "903aae3b-fcbc-44bf-8758-2d1c89fe8b18"}}}}, {"uuid": "d0a83ebe-9d26-4422-a27d-d362ea0d2275", "name": "15f958a3-c7c3-47b4-9e02-9681fef221f7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.737986692242784, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8906640815201406, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6881f547-3f6e-4678-83c3-557c9ad34cfd", "name": "36aa2e1a-aabb-49f5-b74b-8dd8cb98a9ae", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d0a83ebe-9d26-4422-a27d-d362ea0d2275"}}}]}, {"uuid": "4970ad7b-7fdc-4b8e-a6d9-fb76fc0b981c", "name": "load_p1rlv17325_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b96606c-9336-4299-be8d-295c84943a9d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6881f547-3f6e-4678-83c3-557c9ad34cfd"}}}}, {"uuid": "f8cd7541-9f9c-4029-9050-ac9ae9981b61", "name": "3dd2dcda-5b20-4521-9e1c-533b0f4e2d7d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6912886909314806, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4972799611827758, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ef49f829-a2f1-487a-92ae-0a19154aead2", "name": "a1cb7b13-e07d-4b3a-b665-a622a752c384", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8cd7541-9f9c-4029-9050-ac9ae9981b61"}}}]}, {"uuid": "e86268fa-8ad4-49fe-8411-13873c95c5c1", "name": "load_p1rlv17326_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ceb2d77-2da7-44df-9f28-69ed35835775"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ef49f829-a2f1-487a-92ae-0a19154aead2"}}}}, {"uuid": "cf2f9671-7166-4bed-b0e5-cdfe1a3e3407", "name": "b001c8e1-fbe3-4315-9012-5d7b53544280_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6912886909314806, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4972799611827758, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d12cd93b-3287-4394-ad01-9fe19d458e21", "name": "4194c18c-2067-4de4-a9b2-b7305de03e5d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cf2f9671-7166-4bed-b0e5-cdfe1a3e3407"}}}]}, {"uuid": "04c053de-c88f-429f-8ab5-3ded39fef042", "name": "load_p1rlv17326_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ceb2d77-2da7-44df-9f28-69ed35835775"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d12cd93b-3287-4394-ad01-9fe19d458e21"}}}}, {"uuid": "dcad649d-8185-48c6-b750-d5f463a7a21f", "name": "f871a1d5-2c75-44b5-9c2b-723355efeb26_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8996652652050283, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6342298940221502, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f010069f-ea35-4345-9daa-b8507cb0699f", "name": "ebbd0d99-b2f3-4e55-be22-f03e43cb34d0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dcad649d-8185-48c6-b750-d5f463a7a21f"}}}]}, {"uuid": "af64a22c-b338-4f1d-99e4-adc3f6ce48cd", "name": "load_p1rlv17328_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a43eb022-d5e0-47c8-aa36-6ca0d212ab07"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f010069f-ea35-4345-9daa-b8507cb0699f"}}}}, {"uuid": "33b5235b-19af-4e31-8616-eeb491886df0", "name": "59a7faed-ede4-4c0c-8cd0-53d4d59b4b4b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8996652652050283, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6342298940221502, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "362f1e4e-e82c-4263-ad7a-1736626d9256", "name": "a3751d2c-9cb4-4c6e-8aa2-9609fffb808c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "33b5235b-19af-4e31-8616-eeb491886df0"}}}]}, {"uuid": "a5b20244-ff63-44b8-8128-e65520ab9992", "name": "load_p1rlv17328_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a43eb022-d5e0-47c8-aa36-6ca0d212ab07"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "362f1e4e-e82c-4263-ad7a-1736626d9256"}}}}, {"uuid": "502af279-7eef-4cd6-bc11-335a2d01c6a6", "name": "23f5e75d-4b35-4623-8af6-52bc6d890237_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.965154260277072, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307595255595673, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "03e0b75d-f196-4789-b772-0d0bfcdd7467", "name": "05f90df4-2094-4b44-bcff-622bcb412f47", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "502af279-7eef-4cd6-bc11-335a2d01c6a6"}}}]}, {"uuid": "421c3101-a04f-42d9-8430-d2215058afef", "name": "load_p1rlv17329_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61ef37c1-f14f-4b79-a428-d51a6f0d076a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "03e0b75d-f196-4789-b772-0d0bfcdd7467"}}}}, {"uuid": "bf4e7f5c-06b7-48c3-917d-f780ba6569af", "name": "2c20c9c8-ab35-439c-95b8-88a2bec362ee_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.965154260277072, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307595255595673, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4a990b69-4720-4896-a637-88307f139368", "name": "1c6d8545-b014-47e2-b39c-5c9b64403991", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bf4e7f5c-06b7-48c3-917d-f780ba6569af"}}}]}, {"uuid": "2d364ee8-89df-47d3-925d-bc76de773f9f", "name": "load_p1rlv17329_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61ef37c1-f14f-4b79-a428-d51a6f0d076a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4a990b69-4720-4896-a637-88307f139368"}}}}, {"uuid": "73300fee-aac5-4356-8768-a4c425db1b5c", "name": "d1e15fa3-2da0-4791-91b5-615a9f354c5c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.356365911619733, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.9144830945937485, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f87347ec-7156-4651-b922-6d73776421c8", "name": "b99d852e-feb2-4e27-bfa0-3d0a37d1b68f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "73300fee-aac5-4356-8768-a4c425db1b5c"}}}]}, {"uuid": "e33a1b8c-05d1-4e88-aea1-642e6a4b9283", "name": "load_p1rlv17330_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48ad7bb0-8dd7-457a-b77d-6db2071c2fe7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f87347ec-7156-4651-b922-6d73776421c8"}}}}, {"uuid": "e730a872-297b-4984-9f32-ea11e1223742", "name": "bd4c8eca-463f-417e-ad06-5b4f0592da20_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.356365911619733, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.9144830945937485, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "521fd1db-d248-4a5c-837d-8765dbe26545", "name": "de103423-d263-4bc4-8e5f-616aef1079b5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e730a872-297b-4984-9f32-ea11e1223742"}}}]}, {"uuid": "d780e515-74d8-40c6-a7b7-c9071c69af6d", "name": "load_p1rlv17330_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48ad7bb0-8dd7-457a-b77d-6db2071c2fe7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "521fd1db-d248-4a5c-837d-8765dbe26545"}}}}, {"uuid": "1bfcde87-02bf-4ce9-8ed4-7209cb2e19d7", "name": "0295af67-ecd0-486b-af5e-69d9a5cdfe46_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.255903801273714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9789336651099453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "80309df0-588d-49c0-ad64-99b3de9933af", "name": "e0617d38-b588-4c31-9ee1-be55b341fb67", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1bfcde87-02bf-4ce9-8ed4-7209cb2e19d7"}}}]}, {"uuid": "366eed2b-9cc7-4cc8-9a6d-f23d8620b83d", "name": "load_p1rlv17333_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33b66eb9-3b21-4f92-b19b-6a0eef4134d8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "80309df0-588d-49c0-ad64-99b3de9933af"}}}}, {"uuid": "6ae4fcd8-c7f9-45bb-aac8-956b026448cc", "name": "cff104dd-acb7-4b9a-91d7-e355b76ea6b7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.255903801273714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9789336651099453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "abf2ae54-b1d6-4d72-a05f-98f931da19aa", "name": "bd7f4c86-5f03-4e9d-a761-526843704029", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6ae4fcd8-c7f9-45bb-aac8-956b026448cc"}}}]}, {"uuid": "b58c0573-6035-407e-b046-33984fd2092c", "name": "load_p1rlv17333_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33b66eb9-3b21-4f92-b19b-6a0eef4134d8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "abf2ae54-b1d6-4d72-a05f-98f931da19aa"}}}}, {"uuid": "38389ae1-540a-4b72-aa42-af02254ae37f", "name": "657c8f54-5aaa-4854-8bec-9057bdcd69c8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4460841500077097, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.15562665537022718, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dee75f5a-8383-4ed1-9bcb-b2bcf07eb44c", "name": "5f368daa-20fb-4310-ab20-38e603dd0dda", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "38389ae1-540a-4b72-aa42-af02254ae37f"}}}]}, {"uuid": "76335f13-60ce-41e1-9026-922a1d9ecad6", "name": "load_p1rlv17334_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4970bc03-bc57-4a42-b0cb-66002af1709e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dee75f5a-8383-4ed1-9bcb-b2bcf07eb44c"}}}}, {"uuid": "7f4ebfe0-40c5-4bc9-8d1b-595aba889280", "name": "d1f4d03d-b29c-4558-a26c-8a63b1703fbb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4460841500077097, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.15562665537022718, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f40e8fbd-f09a-4cdc-8726-aadbe95b7361", "name": "9e000e2d-2767-4d2f-9a5a-ebc1aace4bc6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7f4ebfe0-40c5-4bc9-8d1b-595aba889280"}}}]}, {"uuid": "4f7252ce-8e0f-41f4-ae5f-1e75102a5f20", "name": "load_p1rlv17334_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4970bc03-bc57-4a42-b0cb-66002af1709e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f40e8fbd-f09a-4cdc-8726-aadbe95b7361"}}}}, {"uuid": "7770234d-62d4-4e13-93b8-9faa62388024", "name": "4c0ed79f-20c9-4da8-9fc7-9b40e54ee282_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.359977223622412, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2969054470018346, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d1ccdca0-093d-4453-a542-dfb77fd0c26f", "name": "735ac888-54bc-4df2-8549-bcd8f865f7ae", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7770234d-62d4-4e13-93b8-9faa62388024"}}}]}, {"uuid": "d7fc5468-3384-4827-b882-e6713879f684", "name": "load_p1rlv17336_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b645969-9136-42a9-b5ac-7d2f1ff71959"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d1ccdca0-093d-4453-a542-dfb77fd0c26f"}}}}, {"uuid": "bc11a223-15f9-48b8-b73b-8370380bc9fd", "name": "19cfeaa7-2b0c-4f67-ac42-d0300df652fb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.359977223622412, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2969054470018346, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e69fe531-0740-4468-9fe7-288bd3769e5f", "name": "5ff19b73-e67a-42e3-9192-f3a4f27649df", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bc11a223-15f9-48b8-b73b-8370380bc9fd"}}}]}, {"uuid": "8396bf77-6765-45f5-82e9-242a84e70f48", "name": "load_p1rlv17336_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b645969-9136-42a9-b5ac-7d2f1ff71959"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e69fe531-0740-4468-9fe7-288bd3769e5f"}}}}, {"uuid": "0f8feaae-af20-4ec3-8b23-e952cb4a6d6e", "name": "83159870-f9d3-442a-97aa-8a42631c32f5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.157838539018536, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.1846823736377714, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "98bd2f16-26b5-47f5-87b1-b3b75c6eb722", "name": "b53c729d-dc99-403d-9bfb-61ee0f06c0ac", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0f8feaae-af20-4ec3-8b23-e952cb4a6d6e"}}}]}, {"uuid": "6e1b9ad7-c909-4865-8432-e7ff483d75c1", "name": "load_p1rlv17337_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5d7049e-9d30-474c-9033-3ad9b4487f7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "98bd2f16-26b5-47f5-87b1-b3b75c6eb722"}}}}, {"uuid": "23ea3d41-4fb0-400f-b006-de183516f61c", "name": "b9274f04-6d81-4bdc-b6b4-9d251c80c79f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.157838539018536, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.1846823736377714, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5e6a5815-3cb1-4b23-9e57-d203e5d85c62", "name": "97315a0a-6423-4943-9a7c-8b41539a03cb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "23ea3d41-4fb0-400f-b006-de183516f61c"}}}]}, {"uuid": "684f5533-f848-4fe6-afd9-8445ebb46174", "name": "load_p1rlv17337_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5d7049e-9d30-474c-9033-3ad9b4487f7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5e6a5815-3cb1-4b23-9e57-d203e5d85c62"}}}}, {"uuid": "5c054edd-c1ec-4d63-b7fd-2207354a66cc", "name": "0b5b75ef-8e44-46a6-a040-396856a4ca71_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.241859724602562, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.250877899038581, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "62397ab6-6a05-426d-8dc3-584c053fff44", "name": "883f491d-1400-4a65-a1fa-92903e5d220f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5c054edd-c1ec-4d63-b7fd-2207354a66cc"}}}]}, {"uuid": "f32efdb4-559e-490e-b395-2486691c556e", "name": "load_p1rlv17338_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "331389ab-5d04-4648-83b4-3043198c774f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "62397ab6-6a05-426d-8dc3-584c053fff44"}}}}, {"uuid": "69d97f87-0ce5-4dad-84fe-c0820689c482", "name": "5c9344f5-ed54-4a4e-9556-05651f149697_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.241859724602562, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.250877899038581, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bdd66b0e-efdd-4dbb-a880-a563704bab7f", "name": "dc6d0468-96f6-4234-8881-da3ca3c8a732", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "69d97f87-0ce5-4dad-84fe-c0820689c482"}}}]}, {"uuid": "24b04968-809c-4f9e-82c9-2393f24ced06", "name": "load_p1rlv17338_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "331389ab-5d04-4648-83b4-3043198c774f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bdd66b0e-efdd-4dbb-a880-a563704bab7f"}}}}, {"uuid": "7d6f6682-4b16-4d78-8341-02dff6a588fe", "name": "5fcda203-655d-453f-95e9-d856be4dda50_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.949137985829372, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.575540256876006, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e10dccc6-c7b1-47cd-88f9-ba4e865bb912", "name": "349bdcdc-edbb-489d-acac-32c5c19e07d2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7d6f6682-4b16-4d78-8341-02dff6a588fe"}}}]}, {"uuid": "72c9ade7-113c-41e7-9225-8cff048b643b", "name": "load_p1rlv17702_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7acb4e7d-cb06-4848-952d-7c68bb34b6db"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e10dccc6-c7b1-47cd-88f9-ba4e865bb912"}}}}, {"uuid": "be52c1ba-3322-4d4f-a639-ed481cdafb06", "name": "1c903b5f-69b3-4a5f-826c-408a365c6bd8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.949137985829372, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.575540256876006, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "450b1b56-3277-4891-bb72-afcc79768b33", "name": "2789a382-ddb9-43ab-bc92-aec08e51abb1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "be52c1ba-3322-4d4f-a639-ed481cdafb06"}}}]}, {"uuid": "5fc87cb6-ada6-4067-b553-daebcf1caece", "name": "load_p1rlv17702_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7acb4e7d-cb06-4848-952d-7c68bb34b6db"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "450b1b56-3277-4891-bb72-afcc79768b33"}}}}, {"uuid": "54432679-b6b2-4d78-ab72-45c674f6e4c7", "name": "cbff83cc-f4cb-4058-a0fc-21d41805ea63_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.965154260277072, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307595255595673, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b029dfda-8738-4211-924a-5b1ccf2b13c9", "name": "e0b5bc66-cdee-4562-9a95-1f343869399a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "54432679-b6b2-4d78-ab72-45c674f6e4c7"}}}]}, {"uuid": "f405c86c-6283-4e82-94df-f7684c805921", "name": "load_p1rlv17781_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a52db2ff-b782-40c1-828a-c65f6929b2fc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b029dfda-8738-4211-924a-5b1ccf2b13c9"}}}}, {"uuid": "1e999895-719f-4b49-b2c7-7a104578adb6", "name": "8bc0e0ee-ff40-4d1e-baee-9f86e3507dbf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.965154260277072, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307595255595673, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2079d6c3-7144-4c92-bc10-aeffc20e685f", "name": "9a9e85ad-5a1d-44fb-b0e2-22b93b6b85b5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1e999895-719f-4b49-b2c7-7a104578adb6"}}}]}, {"uuid": "a61d4b03-911d-42f1-9f8d-c407beccdbeb", "name": "load_p1rlv17781_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a52db2ff-b782-40c1-828a-c65f6929b2fc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2079d6c3-7144-4c92-bc10-aeffc20e685f"}}}}, {"uuid": "3d87410e-83fa-4503-a32b-42bffa2ade70", "name": "9ebe8467-6d47-4b96-aa2a-cc848e2cf97e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.4509454152189125, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9978822313633423, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "198a11c5-9d1e-4caf-a3fd-831192a81b57", "name": "846dcd18-3cee-466e-83b5-1959f08516b3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3d87410e-83fa-4503-a32b-42bffa2ade70"}}}]}, {"uuid": "48206521-093e-4330-82af-1b8be5c79b02", "name": "load_p1rlv17787_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c9c1d9f-eeff-454f-b3d0-7e7de837694c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "198a11c5-9d1e-4caf-a3fd-831192a81b57"}}}}, {"uuid": "163ec51c-f0c1-492c-9666-21946210daaf", "name": "29b335a2-eaf9-48da-817a-17d7c348ac1d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.4509454152189125, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9978822313633423, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8058e3d1-c5b1-4e29-bd83-99287167a6c4", "name": "e1e33dda-f889-4d56-993e-273a46436294", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "163ec51c-f0c1-492c-9666-21946210daaf"}}}]}, {"uuid": "a7bfce45-0f3d-4e66-b3ea-051b6d8c0cf3", "name": "load_p1rlv17787_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c9c1d9f-eeff-454f-b3d0-7e7de837694c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8058e3d1-c5b1-4e29-bd83-99287167a6c4"}}}}, {"uuid": "7b857081-2d81-4bc4-a793-593d6a41b721", "name": "69e968b9-c607-4afc-8481-09a084bce421_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8534881847076217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.812795269620709, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0adc15f9-14b0-4e0c-b445-d886b5f3c16e", "name": "a0a04716-5d5d-4c1e-aa2b-43c7fad31167", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b857081-2d81-4bc4-a793-593d6a41b721"}}}]}, {"uuid": "78c99f01-deb9-4359-9ee0-bb0448e0955b", "name": "load_p1rlv17798_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9dba02d-086c-4906-9c6f-86532e3384c0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0adc15f9-14b0-4e0c-b445-d886b5f3c16e"}}}}, {"uuid": "8555fc92-e9ab-4ffe-b86c-713c278c23fb", "name": "ac94db1f-9834-4f23-8a46-337a25965209_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8534881847076217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.812795269620709, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0cc910e3-3490-41d8-bbf8-a3487362ef2d", "name": "4a6c21e0-2ca4-442d-8d28-1b9ffe7f3dcf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8555fc92-e9ab-4ffe-b86c-713c278c23fb"}}}]}, {"uuid": "aa5c1c56-5a37-4ada-9466-b39ca4a4ea34", "name": "load_p1rlv17798_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9dba02d-086c-4906-9c6f-86532e3384c0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0cc910e3-3490-41d8-bbf8-a3487362ef2d"}}}}, {"uuid": "5f9ef80b-6b91-445d-a78e-777ec0e81b50", "name": "f92c31a2-9402-4e54-9e0f-1de381a81ec1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6844632506969115, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4071315730781585, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d7df6801-627e-4f73-ad3d-f2e3d628eff9", "name": "9efd73ab-497f-47f0-8980-6551b60ee625", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5f9ef80b-6b91-445d-a78e-777ec0e81b50"}}}]}, {"uuid": "3f9bdf0e-f89f-46e9-a0d2-587640eb27bc", "name": "load_p1rlv17810_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3887a879-0783-4703-8a24-32b7e3b4f39d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d7df6801-627e-4f73-ad3d-f2e3d628eff9"}}}}, {"uuid": "14d19e97-d917-49f8-8726-06d23e6a61f8", "name": "58baa9eb-f123-4e37-8b30-8735fcd7f441_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6844632506969115, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4071315730781585, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "445ea327-9707-4c4e-b794-9288514689f9", "name": "52f7ab9d-9e50-48b6-81f3-75cd2228557b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "14d19e97-d917-49f8-8726-06d23e6a61f8"}}}]}, {"uuid": "2f28be03-818a-4f93-af62-e804e4f8052b", "name": "load_p1rlv17810_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3887a879-0783-4703-8a24-32b7e3b4f39d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "445ea327-9707-4c4e-b794-9288514689f9"}}}}, {"uuid": "e14a7e0c-44e6-4636-9145-5902e8696f58", "name": "3454769d-7d63-4a7f-9fe0-6062947119bf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.136651452497737, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.586908988148888, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "25e771ac-e957-447e-8569-3b5b9a12e970", "name": "5674eef4-41c9-43f4-bbe8-54b74a5533d8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e14a7e0c-44e6-4636-9145-5902e8696f58"}}}]}, {"uuid": "c72a25b6-0826-41ad-a0d8-f7b0c4265083", "name": "load_p1rlv17847_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f7776e4-a81f-48d2-b3c0-d70bfa48164e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "25e771ac-e957-447e-8569-3b5b9a12e970"}}}}, {"uuid": "4cf6afae-55af-4626-8b4e-7dbefc832603", "name": "330a397d-5aff-4cbf-aff8-b9fcc9e7f79f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.136651452497737, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.586908988148888, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "35baf397-b50d-4e62-9f61-77b4a7ea8418", "name": "444cc47d-e24e-4637-85d4-6a37566cd207", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4cf6afae-55af-4626-8b4e-7dbefc832603"}}}]}, {"uuid": "eee5393e-00d6-46c7-b18b-a0f91f0d99fe", "name": "load_p1rlv17847_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f7776e4-a81f-48d2-b3c0-d70bfa48164e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "35baf397-b50d-4e62-9f61-77b4a7ea8418"}}}}, {"uuid": "6e098042-e93f-4831-8ac8-ae75c7f70985", "name": "ef62be26-4c67-45c8-99db-2e14e7c2275b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3135149757913545, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7371070877725675, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7a47240f-01a4-41ee-b4b9-72dc87b5daec", "name": "ceca9648-b1df-47a9-9014-80d9e01f1dd8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6e098042-e93f-4831-8ac8-ae75c7f70985"}}}]}, {"uuid": "5498629b-d009-4516-acf5-664b97cf89c2", "name": "load_p1rlv17857_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0827675c-2467-403d-822e-5f74cd6296c5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7a47240f-01a4-41ee-b4b9-72dc87b5daec"}}}}, {"uuid": "a47d8cd3-ed11-4b5f-9db3-c4a0034a9ca4", "name": "fb659191-f009-41b2-b21f-120fa0247c8f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3135149757913545, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7371070877725675, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fca87ce0-49b3-4835-820a-8be2bcae6903", "name": "251ff752-b29c-40ce-bba4-4314bc46db73", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a47d8cd3-ed11-4b5f-9db3-c4a0034a9ca4"}}}]}, {"uuid": "c858a7f0-8223-4efb-a2d9-b2882fb6d971", "name": "load_p1rlv17857_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0827675c-2467-403d-822e-5f74cd6296c5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fca87ce0-49b3-4835-820a-8be2bcae6903"}}}}, {"uuid": "785da82f-5373-452b-8227-90ab120ca7b4", "name": "56bf38fa-cd89-4dbe-8b53-49af2e32ed1f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.443583112785006, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2576306570382033, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fef70936-b654-42b2-be1b-86b55a67b30a", "name": "79526ef0-8a1f-4b6e-843f-8bb1698ea65f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "785da82f-5373-452b-8227-90ab120ca7b4"}}}]}, {"uuid": "a4d5dbc3-0330-411d-8a82-6a7737083b0e", "name": "load_p1rlv17876_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75e55237-b847-4fb7-a141-a0771bd868c6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fef70936-b654-42b2-be1b-86b55a67b30a"}}}}, {"uuid": "1e9a1961-e7a9-4146-80c2-cf66003e17ba", "name": "72125487-3fd7-4146-bfb6-029c8fb66e97_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.443583112785006, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2576306570382033, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b1747e1a-b340-4027-b5b4-cdc0451196ad", "name": "66e84d45-331d-4185-a59d-2323e03033d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1e9a1961-e7a9-4146-80c2-cf66003e17ba"}}}]}, {"uuid": "57dc88b8-3fa0-4d70-9b9e-b9d84be074a7", "name": "load_p1rlv17876_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75e55237-b847-4fb7-a141-a0771bd868c6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b1747e1a-b340-4027-b5b4-cdc0451196ad"}}}}, {"uuid": "2a816c78-b7c5-4dae-86bc-556d575808b4", "name": "f8759381-73dd-4b2d-9110-80d5e846c70e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1426015471760884, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5928311844731246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cc7bc10a-874e-4459-af46-b5b0f7ad1bc6", "name": "93601803-22d6-4ad7-bb7d-e7211b2a59ff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2a816c78-b7c5-4dae-86bc-556d575808b4"}}}]}, {"uuid": "7a66ce02-8f45-4802-ae36-c25ff587b520", "name": "load_p1rlv17877_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f44b0293-61e5-4054-b2d7-4a113df92b3c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cc7bc10a-874e-4459-af46-b5b0f7ad1bc6"}}}}, {"uuid": "0c3e0615-8667-4df0-b786-134737220183", "name": "e87fd7ce-4d9e-463c-8d0a-3c500e9b8401_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1426015471760884, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5928311844731246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2efdaf05-7c0b-491c-9674-03bc78329797", "name": "f88041bf-92ed-424b-820b-e0481e549c88", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0c3e0615-8667-4df0-b786-134737220183"}}}]}, {"uuid": "613a4a65-8be2-4936-a8bd-f65d054605f7", "name": "load_p1rlv17877_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f44b0293-61e5-4054-b2d7-4a113df92b3c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2efdaf05-7c0b-491c-9674-03bc78329797"}}}}, {"uuid": "747c2cc6-2d86-4f59-9ca8-530bb0f6ba8d", "name": "46b5cdf4-3ff2-4a1c-bef2-2d57a001d3ef_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.67620786252276, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6753067705079763, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0af8c976-a6e0-4470-bc59-1d8800943c1a", "name": "1d4b0369-7042-401d-a28a-16884ca6b2c7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "747c2cc6-2d86-4f59-9ca8-530bb0f6ba8d"}}}]}, {"uuid": "e3f310df-f0c4-4b89-9432-0bab91f2241d", "name": "load_p1rlv17897_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f74f217-4765-406d-9646-d8f46377ef0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0af8c976-a6e0-4470-bc59-1d8800943c1a"}}}}, {"uuid": "0c405577-dccd-493a-bd4b-e52011412b9e", "name": "deab8b54-668c-47ff-8a8c-9d158ba82837_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.67620786252276, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6753067705079763, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c33af26c-c73a-4bf3-8252-dd6b48f69ce1", "name": "bd9a4bb0-985a-4626-9645-2d8b3c4c0fec", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0c405577-dccd-493a-bd4b-e52011412b9e"}}}]}, {"uuid": "3ac79b34-2d50-40be-baa0-efbb85f6253d", "name": "load_p1rlv17897_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f74f217-4765-406d-9646-d8f46377ef0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c33af26c-c73a-4bf3-8252-dd6b48f69ce1"}}}}, {"uuid": "673954b0-f374-4cea-81d2-77aae21ac239", "name": "c7ca9f33-6dee-4b99-ab2e-c6fd7b8f141c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3841896439528762, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.62886585412856, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "43870935-1fbe-4419-a912-eabaf277738d", "name": "1f44b787-71df-4d82-892f-ed486384c677", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "673954b0-f374-4cea-81d2-77aae21ac239"}}}]}, {"uuid": "f146f258-d046-4e2f-92cf-fa17ae5d53a8", "name": "load_p1rlv17909_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab733d49-bb36-4631-8824-1967f98f758a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "43870935-1fbe-4419-a912-eabaf277738d"}}}}, {"uuid": "b0f16155-341f-4fef-9b89-4ba76fa3fa9b", "name": "184ed837-46d1-48b6-9e40-41454e4f4529_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3841896439528762, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.62886585412856, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0cc76fc8-659e-45fa-8c82-49735e94aa6e", "name": "756b0c1d-4183-4f16-93fb-62c0a6c14c1b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b0f16155-341f-4fef-9b89-4ba76fa3fa9b"}}}]}, {"uuid": "8b089298-c576-4ac5-8380-4d3a995dd365", "name": "load_p1rlv17909_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab733d49-bb36-4631-8824-1967f98f758a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0cc76fc8-659e-45fa-8c82-49735e94aa6e"}}}}, {"uuid": "85580e6f-4336-4378-8593-aa5e7f997af6", "name": "c78d97da-dbb2-40cc-a767-670b78cef609_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5290895920961123, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.36247808422876804, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "737497c3-2c01-4ab2-a5db-da56979d37c2", "name": "ab66c99b-9660-48d5-a102-d31d5ad73bc4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "85580e6f-4336-4378-8593-aa5e7f997af6"}}}]}, {"uuid": "554a2fbd-8de1-491f-9962-641362d00fec", "name": "load_p1rlv17912_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3eb66d3-0271-4842-8893-9a58f64e0279"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "737497c3-2c01-4ab2-a5db-da56979d37c2"}}}}, {"uuid": "35e16783-6c79-4cb2-8388-75a45ee8381c", "name": "27882881-f8f6-46ab-afa3-e2c94a85c378_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5290895920961123, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.36247808422876804, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "32cacb6c-cb9e-4d0b-bb0b-6ecc9421fcf1", "name": "2b39f0f8-eee4-4971-9ef8-b5929d463593", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "35e16783-6c79-4cb2-8388-75a45ee8381c"}}}]}, {"uuid": "ab4939ac-f9c6-4ce9-9625-94b0d4bcd5dc", "name": "load_p1rlv17912_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3eb66d3-0271-4842-8893-9a58f64e0279"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "32cacb6c-cb9e-4d0b-bb0b-6ecc9421fcf1"}}}}, {"uuid": "f121e983-b923-4500-a667-b0c458477d72", "name": "c4c3ef96-98c9-4de0-87a3-17dba1f39788_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.53872088738556, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0484090155056416, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "58b14df9-08c0-4c7d-8ffc-c69eb560f186", "name": "7454fbd0-0e55-4473-851a-edf12b088e6e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f121e983-b923-4500-a667-b0c458477d72"}}}]}, {"uuid": "72a62921-b6d9-4e38-948d-caef55f4832f", "name": "load_p1rlv17926_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2812bbb1-0bb0-499f-a394-0995784bb7bc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "58b14df9-08c0-4c7d-8ffc-c69eb560f186"}}}}, {"uuid": "c9d24559-cd5e-43ad-b30e-90aa7792fc53", "name": "467c2215-dde7-4a09-a503-571ccf8670c0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.53872088738556, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0484090155056416, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "873ca082-8d2a-4bbd-b64a-200399a7fa2e", "name": "ba080ed0-a082-40d1-870d-4cd6e9d28483", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9d24559-cd5e-43ad-b30e-90aa7792fc53"}}}]}, {"uuid": "dfa5b295-8bae-42f3-bac4-7cbd34dbd9b5", "name": "load_p1rlv17926_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2812bbb1-0bb0-499f-a394-0995784bb7bc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "873ca082-8d2a-4bbd-b64a-200399a7fa2e"}}}}, {"uuid": "a51df733-a1a0-44c8-b6da-4e51ae456dab", "name": "9727774c-93bc-41c4-8516-53ded346a01a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9243645178497548, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1029763549760416, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0b144409-29f3-4aae-973f-de0f15942722", "name": "f9d605d1-f989-4bbe-8d7d-3ee66c387489", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a51df733-a1a0-44c8-b6da-4e51ae456dab"}}}]}, {"uuid": "8dcabd59-b0bb-4578-9b9a-ddf3e05199bc", "name": "load_p1rlv17960_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "215a5974-e23b-46f0-bde9-f5ad16fdfaf8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0b144409-29f3-4aae-973f-de0f15942722"}}}}, {"uuid": "18d35654-eabd-48ad-b40e-e1a5f9d70b65", "name": "49f0a928-a1cd-4c63-b22d-ca6193302c0f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9243645178497548, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1029763549760416, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aed5f5f5-d1fc-428c-a25d-04a11d59a468", "name": "175c910f-8a28-4c5a-91dc-3c92d43f6a92", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "18d35654-eabd-48ad-b40e-e1a5f9d70b65"}}}]}, {"uuid": "7d94f70f-8b62-40ed-8e1a-3ef30f8baa32", "name": "load_p1rlv17960_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "215a5974-e23b-46f0-bde9-f5ad16fdfaf8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aed5f5f5-d1fc-428c-a25d-04a11d59a468"}}}}, {"uuid": "bef3716f-841e-42a0-b5c6-ad05d7d4b39e", "name": "40099928-ff6e-442e-926b-0313269e41dc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.498014754859445, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "38bf2759-9d5a-4191-81c9-7b6a88469a70", "name": "824f1227-95e5-416c-a14b-112fac6a710b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bef3716f-841e-42a0-b5c6-ad05d7d4b39e"}}}]}, {"uuid": "994236b6-d001-4192-9f84-405c6a284793", "name": "load_p1rlv17961_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2716887e-1701-4a78-805b-96da0781c7f8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "38bf2759-9d5a-4191-81c9-7b6a88469a70"}}}}, {"uuid": "e0606768-9b13-4f11-a250-4360c3e94b74", "name": "428da6b8-fa3a-4e61-9877-bb07755f3169_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.498014754859445, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dff768e5-d8c7-42b4-b30a-4e42f71261e9", "name": "9caf0ad2-af21-40a4-9e1a-a10322d5057f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e0606768-9b13-4f11-a250-4360c3e94b74"}}}]}, {"uuid": "eb5a0498-5956-4b87-9295-49e532a7dfe7", "name": "load_p1rlv17961_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2716887e-1701-4a78-805b-96da0781c7f8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dff768e5-d8c7-42b4-b30a-4e42f71261e9"}}}}, {"uuid": "9efb896d-0011-455d-b26f-581c13ab6ba1", "name": "e8f4e742-6ae7-41d1-aea6-4737074853a8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4651344294517608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7736313908316925, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1e24c802-acb4-4c9d-8e8b-82548499c030", "name": "20f50e06-ba44-4c08-a440-ac3d0c0ff194", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9efb896d-0011-455d-b26f-581c13ab6ba1"}}}]}, {"uuid": "522399a3-eb8a-4295-a203-4ad7992130ab", "name": "load_p1rlv17962_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec99daac-e0be-4ea1-ba4f-185d4943396d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1e24c802-acb4-4c9d-8e8b-82548499c030"}}}}, {"uuid": "929ca6ca-a3ce-42e9-a5e6-6a795631e22f", "name": "b3e41a9f-aa35-425f-ac89-4956de4a32e6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4651344294517608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7736313908316925, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a0ae656-44fb-451e-9ce3-335ca2aa43ad", "name": "5fd5411c-5965-4e7f-bef9-5bcb02bfb77e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "929ca6ca-a3ce-42e9-a5e6-6a795631e22f"}}}]}, {"uuid": "1cc045b5-a3a0-4869-a60f-a759e5eb16dd", "name": "load_p1rlv17962_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec99daac-e0be-4ea1-ba4f-185d4943396d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a0ae656-44fb-451e-9ce3-335ca2aa43ad"}}}}, {"uuid": "80c1306a-2395-499e-8d7b-a00ea5cbc1f5", "name": "36e9c8af-fb21-4fd7-ab9a-069eb5405324_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.107858967059457, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3651352875232526, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "575b6888-0bd4-41d2-b5c0-3b2efbd2bc27", "name": "4da172cc-66c4-41ea-a05f-8bc6c686b27a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "80c1306a-2395-499e-8d7b-a00ea5cbc1f5"}}}]}, {"uuid": "1a13d31f-dd8c-48db-9566-bb8555ff2eb6", "name": "load_p1rlv17969_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ccaf70a-35d8-4f16-b632-e282fe30b5ca"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "575b6888-0bd4-41d2-b5c0-3b2efbd2bc27"}}}}, {"uuid": "356eac4e-c227-4733-ad20-430ccd100a54", "name": "3bb91beb-def4-4ac9-837d-d19d44558d5b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.107858967059457, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3651352875232526, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4b44aed9-c5e4-43b8-850e-8d81021d55fa", "name": "c94f6aee-952d-4b57-8918-e23555512cf6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "356eac4e-c227-4733-ad20-430ccd100a54"}}}]}, {"uuid": "9bc6eff4-5e3a-4c95-9a8d-c503e9b2f022", "name": "load_p1rlv17969_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ccaf70a-35d8-4f16-b632-e282fe30b5ca"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4b44aed9-c5e4-43b8-850e-8d81021d55fa"}}}}, {"uuid": "7c8c52d7-c1da-4a84-9f8b-6da12b106261", "name": "e8394590-bd10-43e1-8be7-11875e03895a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8939358223380807, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6690937458929831, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "15f03cc3-4b5f-44ca-bf57-a3bfdbcaf20c", "name": "e884a5e6-d820-4ea9-88d5-f95975577ddd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7c8c52d7-c1da-4a84-9f8b-6da12b106261"}}}]}, {"uuid": "761d9060-9915-4396-823f-9d89270cc816", "name": "load_p1rlv17987_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0771ebfa-5eaf-4ae8-94f1-86de7a656f58"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "15f03cc3-4b5f-44ca-bf57-a3bfdbcaf20c"}}}}, {"uuid": "09143581-c632-4b97-9e2d-846f065ae568", "name": "c79622ae-1a19-4bd6-9a02-44a40c1271ed_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8939358223380807, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6690937458929831, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0770b80e-1ba4-4142-bbad-cb21fc5a7bf0", "name": "8e94e562-b508-49aa-9243-e8ee4ca25e68", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "09143581-c632-4b97-9e2d-846f065ae568"}}}]}, {"uuid": "55c4c05e-ffa0-4950-ab16-60ea16d44777", "name": "load_p1rlv17987_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0771ebfa-5eaf-4ae8-94f1-86de7a656f58"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0770b80e-1ba4-4142-bbad-cb21fc5a7bf0"}}}}, {"uuid": "7d268e87-7787-4271-8a16-4ca5cbd5b1ad", "name": "8f2eb056-9539-463c-bd7d-a24c464d0f5b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0404861968223509, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5307917165881004, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f336219e-e2ac-4bc3-a323-65e4d9edb635", "name": "c8fffeef-26c4-4fb7-a4e3-d188a91238ac", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7d268e87-7787-4271-8a16-4ca5cbd5b1ad"}}}]}, {"uuid": "c7e08a67-99af-4662-9700-745aab48ccab", "name": "load_p1rlv18044_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b40fac8c-a99b-4baa-940a-26565ba7d62b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f336219e-e2ac-4bc3-a323-65e4d9edb635"}}}}, {"uuid": "fd34ef56-f97c-4d4e-91c8-1b0e1d0d6fd7", "name": "7e460095-9f92-44b2-b8b5-9fab9d29e144_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0404861968223509, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5307917165881004, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "420f9a97-b7fc-4c97-b066-8df50a178869", "name": "329acef9-99ed-4b46-8b52-a131f586e947", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fd34ef56-f97c-4d4e-91c8-1b0e1d0d6fd7"}}}]}, {"uuid": "47e7ab04-3e9f-430e-be73-1584529a1096", "name": "load_p1rlv18044_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b40fac8c-a99b-4baa-940a-26565ba7d62b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "420f9a97-b7fc-4c97-b066-8df50a178869"}}}}, {"uuid": "5df3cb72-beb9-4ad3-b570-6d9cc60d23da", "name": "1b28d631-8654-4420-a891-23e721aae671_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.199673234956728, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.25859312667494616, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3adf9d10-fdb0-4c38-bf75-0d97ef0b4aaa", "name": "ec3d2672-b86c-4faf-9e3e-1457857bc427", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5df3cb72-beb9-4ad3-b570-6d9cc60d23da"}}}]}, {"uuid": "f12b8f76-6571-4c39-bfdd-40132252b81e", "name": "load_p1rlv18053_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4aeda1c7-41be-43c8-82e5-d7a347db86a8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3adf9d10-fdb0-4c38-bf75-0d97ef0b4aaa"}}}}, {"uuid": "79bf0340-ffdb-466c-9259-6dc5218d6227", "name": "4d063cd1-4fff-4f98-8177-f8adbb31c500_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.199673234956728, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.25859312667494616, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "60274c84-23f5-44ff-99e7-ad3b25f47512", "name": "3afce734-0a45-4eba-88ab-17b0dbd76aa7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "79bf0340-ffdb-466c-9259-6dc5218d6227"}}}]}, {"uuid": "4654b7ec-a734-477b-b98c-9cb10503571f", "name": "load_p1rlv18053_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4aeda1c7-41be-43c8-82e5-d7a347db86a8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "60274c84-23f5-44ff-99e7-ad3b25f47512"}}}}, {"uuid": "3e27d3ad-838f-4703-8e56-d400c5f8a3ce", "name": "3fcdee97-11a1-400c-b114-7c40df65b086_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7675749799903273, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6204429178040327, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "958bd145-fde9-484a-acfb-51e25fc3f9c8", "name": "ed7798d9-a2ac-41f6-b2e8-c2c2edac844e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3e27d3ad-838f-4703-8e56-d400c5f8a3ce"}}}]}, {"uuid": "88995c28-9ad6-4253-b4e5-abd41ca9e893", "name": "load_p1rlv18071_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86917829-123c-4fda-9809-dc61430a9fef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "958bd145-fde9-484a-acfb-51e25fc3f9c8"}}}}, {"uuid": "e771654a-ed9a-4ad0-b64e-2fbfa5239ffd", "name": "fa50f85a-044f-49a5-923f-a7bcddb40686_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7675749799903273, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6204429178040327, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b099b994-1dac-48a6-bafa-305c627fe7bd", "name": "34354eae-b6d8-4527-8a04-babf22ff2f34", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e771654a-ed9a-4ad0-b64e-2fbfa5239ffd"}}}]}, {"uuid": "1a472225-fbb8-44a1-b0ef-094c201ca96d", "name": "load_p1rlv18071_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86917829-123c-4fda-9809-dc61430a9fef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b099b994-1dac-48a6-bafa-305c627fe7bd"}}}}, {"uuid": "03075fc0-3dbe-4162-8d65-f42b924a9a81", "name": "cea04c29-238b-4c69-ab2d-8c7e7dd7b301_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2005170978204305, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8833048630127251, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cccf2bd5-fc9b-4b22-ad4f-6e60c8241b9b", "name": "6ca40b0d-06cc-469c-8da4-ce0f4ad063d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "03075fc0-3dbe-4162-8d65-f42b924a9a81"}}}]}, {"uuid": "28148e11-d3f7-4090-99b7-f2914a7771c7", "name": "load_p1rlv18100_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4863d28-4ee2-479d-accb-60b54f472fe7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cccf2bd5-fc9b-4b22-ad4f-6e60c8241b9b"}}}}, {"uuid": "d1cb8122-5757-430c-8855-0127ca1873f2", "name": "27c4cb99-9a24-411d-9960-24b11ac0eaec_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2005170978204305, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8833048630127251, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b05810b3-1268-45d7-9846-95cd0ad29b3c", "name": "5a0826ab-1ad9-460a-9b0c-cd7b6a386ea4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d1cb8122-5757-430c-8855-0127ca1873f2"}}}]}, {"uuid": "33841819-e3a2-4fec-a57f-b1864081f314", "name": "load_p1rlv18100_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4863d28-4ee2-479d-accb-60b54f472fe7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b05810b3-1268-45d7-9846-95cd0ad29b3c"}}}}, {"uuid": "8c72effc-f49a-4c58-ad55-22badf2f583d", "name": "2e352eb8-6201-4c37-ba59-10a9cb0eb2f3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2075389461119934, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3167249782629938, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "986789eb-fe6d-4ef7-840f-e5fcbf1e3bc0", "name": "bde6c827-9d2c-411b-a06d-3ba379010267", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8c72effc-f49a-4c58-ad55-22badf2f583d"}}}]}, {"uuid": "f2cfd818-8882-43e9-addd-e0ad44040a28", "name": "load_p1rlv18129_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "115a848f-f6f3-48f0-9f33-5a9103f1a892"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "986789eb-fe6d-4ef7-840f-e5fcbf1e3bc0"}}}}, {"uuid": "5a2ce607-31a7-40a7-8a80-162bb5787360", "name": "021e46a8-a5d4-4dc6-aa79-874afe956e42_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2075389461119934, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3167249782629938, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e9dab9c4-3f86-4dc0-bf0d-ba3fc0e13621", "name": "4569044e-ce09-49e1-9104-2878e36f1ec2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5a2ce607-31a7-40a7-8a80-162bb5787360"}}}]}, {"uuid": "4dbcd618-27f3-417a-9b1d-07e0894cd8f9", "name": "load_p1rlv18129_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "115a848f-f6f3-48f0-9f33-5a9103f1a892"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e9dab9c4-3f86-4dc0-bf0d-ba3fc0e13621"}}}}, {"uuid": "ed97d495-4878-4728-805d-f857a3a611ec", "name": "fc62f661-92ad-4639-88e3-9dca6a64180c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3268329182243828, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6606620655388332, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "12991d25-4c53-47d7-ab45-adc402c143d3", "name": "736cf412-ac15-4084-8de1-411be757913f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ed97d495-4878-4728-805d-f857a3a611ec"}}}]}, {"uuid": "f1da61cb-3884-4f89-b184-c3708d29eb39", "name": "load_p1rlv18166_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "431692e5-2917-41ea-aafc-96be180b7e27"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "12991d25-4c53-47d7-ab45-adc402c143d3"}}}}, {"uuid": "9d66f1fa-41a6-4581-ab8c-81e89618b04b", "name": "4cdb61f2-3a90-4f0c-ab4c-7a53207cf31a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3268329182243828, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6606620655388332, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d9c8f299-4954-40a4-a240-cd2adae70530", "name": "e14d0abd-926d-4b2e-83f2-6afa1fdc9b5b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9d66f1fa-41a6-4581-ab8c-81e89618b04b"}}}]}, {"uuid": "ebf7542b-7eda-4a54-ab7f-c9324bbf5e8d", "name": "load_p1rlv18166_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "431692e5-2917-41ea-aafc-96be180b7e27"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d9c8f299-4954-40a4-a240-cd2adae70530"}}}}, {"uuid": "ab46062b-f641-4da2-96c8-8c433018dd78", "name": "6972b329-1f10-4ef6-ad40-e76563e89199_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cc9487f5-2aab-43b3-992e-54f57e90d5c8", "name": "a56b133d-f339-48b0-b8e0-08351d898d96", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ab46062b-f641-4da2-96c8-8c433018dd78"}}}]}, {"uuid": "fb84b9e0-2dfe-44a9-a3f1-93c28e583a40", "name": "load_p1rlv18192_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c3e08a8-ea88-423d-b361-69509f7ab8fa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cc9487f5-2aab-43b3-992e-54f57e90d5c8"}}}}, {"uuid": "951d662a-0416-45f2-9997-c6e140565f83", "name": "45acbd5f-b7e8-46f1-a2e5-e99e1003350d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8434317b-50f4-4029-ab69-190b32871133", "name": "640917a0-312a-47c7-b00a-50b0d8a1dbf9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "951d662a-0416-45f2-9997-c6e140565f83"}}}]}, {"uuid": "2b1900a9-e3e5-4074-8d8d-25af0c96225a", "name": "load_p1rlv18192_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c3e08a8-ea88-423d-b361-69509f7ab8fa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8434317b-50f4-4029-ab69-190b32871133"}}}}, {"uuid": "b61f3f55-672b-4cad-aa77-43e4ce9bc1fc", "name": "75ffe928-d893-4390-b50f-05c00ef1ff76_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.948680292874151, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.769988963438003, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4882a0c1-919d-4da2-bc38-44888d427089", "name": "dc460813-a025-4a1b-9de4-26291cf0936d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b61f3f55-672b-4cad-aa77-43e4ce9bc1fc"}}}]}, {"uuid": "a07e8600-88ab-4422-91ff-ca68999aa185", "name": "load_p1rlv18197_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5e240e8-b27d-4181-a7ee-a004d3f5c58a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4882a0c1-919d-4da2-bc38-44888d427089"}}}}, {"uuid": "d0976f00-4aaa-4faa-9f7b-963cf6661a53", "name": "f4ed0f48-252c-4744-a8be-47521bb9e690_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.948680292874151, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.769988963438003, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9b834b4a-d6dd-458e-aa5e-c4b66586c32f", "name": "1d36f195-ab24-4b30-bc04-92e9ff7f7c9e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d0976f00-4aaa-4faa-9f7b-963cf6661a53"}}}]}, {"uuid": "e45885c7-2504-4309-9bf3-26a2709f647b", "name": "load_p1rlv18197_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5e240e8-b27d-4181-a7ee-a004d3f5c58a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9b834b4a-d6dd-458e-aa5e-c4b66586c32f"}}}}, {"uuid": "b44a5637-33ac-43e4-9b88-35bcc319c1f3", "name": "03c05035-fe62-4427-a676-da984a6bb1d9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1698158732703443, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8490689598373361, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7f7cd507-7c9d-44bc-8133-69917dbfc87c", "name": "ea4fc29e-6ff7-42a4-bb90-eab6be3af249", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b44a5637-33ac-43e4-9b88-35bcc319c1f3"}}}]}, {"uuid": "c4fbfa3b-3dc0-41e9-b442-03e16247c0a4", "name": "load_p1rlv18198_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a7cb078-af6c-4cd5-9aca-48f515f6e711"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7f7cd507-7c9d-44bc-8133-69917dbfc87c"}}}}, {"uuid": "e479fb2f-4e22-4c7a-b453-75f36c005814", "name": "50472ce7-6c1e-4b22-83fa-668d103c6d6f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1698158732703443, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8490689598373361, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f4b23009-956b-4690-aabc-ec574695bed0", "name": "69dad363-7f6e-43f7-ba5a-a1783a4cf1a8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e479fb2f-4e22-4c7a-b453-75f36c005814"}}}]}, {"uuid": "1a5ed19a-7d46-43e6-9691-6d3f55153c9f", "name": "load_p1rlv18198_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a7cb078-af6c-4cd5-9aca-48f515f6e711"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f4b23009-956b-4690-aabc-ec574695bed0"}}}}, {"uuid": "276ea94c-e3c1-4cc5-9859-3a79835d1732", "name": "7e861e6f-9889-4f20-a5da-ebcb502d6916_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1801024488747824, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6406661654566495, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "08b7b6d3-4881-4ee5-9ec6-4bfc51ec49ce", "name": "3f5ce7bc-bb23-445c-8e73-acaedd6d90a8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "276ea94c-e3c1-4cc5-9859-3a79835d1732"}}}]}, {"uuid": "299e6517-f4c9-4ce7-9581-76c2055f841a", "name": "load_p1rlv18960_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9178fdee-311f-40f5-bdd6-9b474a05247e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "08b7b6d3-4881-4ee5-9ec6-4bfc51ec49ce"}}}}, {"uuid": "72d93b5a-33ab-47bb-9adb-4ff1c9b299df", "name": "1696a9c2-4c7e-4554-aca7-0a06eb4fdd48_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1801024488747824, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6406661654566495, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "09b995d5-0033-485f-b28a-8760affaac32", "name": "464a37f8-2e6d-4d9c-bb83-37ddc44d0fab", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72d93b5a-33ab-47bb-9adb-4ff1c9b299df"}}}]}, {"uuid": "51ed28f6-fde9-4502-9bde-3b93db46f283", "name": "load_p1rlv18960_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9178fdee-311f-40f5-bdd6-9b474a05247e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "09b995d5-0033-485f-b28a-8760affaac32"}}}}, {"uuid": "899a49e6-7b69-4db2-8d09-8925b0ce3fb1", "name": "8053ebbb-7ea6-4faa-aa26-0b9f67c1feff_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2045141672666357, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3046267940472902, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "51a0facb-5b80-4fbb-9975-cb7581507496", "name": "91d20e8a-8b70-460f-b8fb-8ae972a78dc1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "899a49e6-7b69-4db2-8d09-8925b0ce3fb1"}}}]}, {"uuid": "2f8f440f-bdcc-448e-8f86-8b00ebb2acfc", "name": "load_p1rlv18967_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eef4f0cf-6e51-45e1-8b6e-84171f7cbef6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "51a0facb-5b80-4fbb-9975-cb7581507496"}}}}, {"uuid": "a725c8c0-7954-4257-9a35-a61da37a2e42", "name": "70fcedb9-cf7e-4485-9a0f-9e1e11138e2f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2045141672666357, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3046267940472902, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fe11e8fd-a436-4ca3-bd2b-cc95dca6b5fa", "name": "13bd4487-3d1d-4764-b85b-3eba9ec1eeef", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a725c8c0-7954-4257-9a35-a61da37a2e42"}}}]}, {"uuid": "9cc09d32-0935-4602-a270-cf01750eee4d", "name": "load_p1rlv18967_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eef4f0cf-6e51-45e1-8b6e-84171f7cbef6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fe11e8fd-a436-4ca3-bd2b-cc95dca6b5fa"}}}}, {"uuid": "1bc226e4-d825-48c6-b833-fe32cf0ae345", "name": "177bb8d7-148a-41b3-b2de-a89663e90700_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1222862909492073, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34523553920221683, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "125c1e25-a0ec-48cd-8e28-e7715a931e54", "name": "e722f372-88ba-4e37-8b0a-bd6dc16ffd8b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1bc226e4-d825-48c6-b833-fe32cf0ae345"}}}]}, {"uuid": "2f9a01e1-3bf0-4357-891e-89f0f5382d4b", "name": "load_p1rlv19146_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0bb184ad-cb26-4317-8c40-f2c8a9f80dab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "125c1e25-a0ec-48cd-8e28-e7715a931e54"}}}}, {"uuid": "d34e1d78-8d7c-417c-8892-0c55830d30ab", "name": "ff88758b-f910-4a31-8511-29aa0ed51445_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1222862909492073, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34523553920221683, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1ece6b38-82a3-43f4-84c9-09f1840cdf2b", "name": "a65f33d6-bdcc-4356-a949-430509372f0f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d34e1d78-8d7c-417c-8892-0c55830d30ab"}}}]}, {"uuid": "d93487e0-e966-46e0-8d01-1def495b974d", "name": "load_p1rlv19146_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0bb184ad-cb26-4317-8c40-f2c8a9f80dab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1ece6b38-82a3-43f4-84c9-09f1840cdf2b"}}}}, {"uuid": "69f7dbef-382f-4102-a948-57f2c415c946", "name": "a189b0be-1b52-4fcf-a047-5b79aafa0cb8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4868228207229564, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16976956391895093, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d130eab6-4e26-4eef-a078-d7c0b36a6ffc", "name": "90529770-274c-4c96-bb3b-977a5634b8af", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "69f7dbef-382f-4102-a948-57f2c415c946"}}}]}, {"uuid": "6e5c4f0f-df78-4714-9ce1-7d7261bf01ac", "name": "load_p1rlv19147_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "546433b3-d70e-49ed-9037-ec88adda79b9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d130eab6-4e26-4eef-a078-d7c0b36a6ffc"}}}}, {"uuid": "0a53069c-3064-4f06-872d-870fd265d2c3", "name": "6b8cac3e-b265-423f-8f4f-f24c760d8254_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4868228207229564, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16976956391895093, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "36dc5985-18ba-4e5e-9854-e0c0d806f1f2", "name": "487d7df3-d4f2-4ca3-b2f5-ddc7e6da5c1c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0a53069c-3064-4f06-872d-870fd265d2c3"}}}]}, {"uuid": "f6467e30-51e9-4a90-940c-a4135378cf12", "name": "load_p1rlv19147_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "546433b3-d70e-49ed-9037-ec88adda79b9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "36dc5985-18ba-4e5e-9854-e0c0d806f1f2"}}}}, {"uuid": "e0a27af4-c819-4cc9-9bec-a802754241a8", "name": "61c65a95-d6be-490c-865f-253fc9479b67_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "11b78b7d-430d-4a8d-bef5-0b834f29a3da", "name": "5165893a-7e75-4e7b-bb10-423a322366b4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e0a27af4-c819-4cc9-9bec-a802754241a8"}}}]}, {"uuid": "b4ee36f5-ff72-4a5a-9ce9-8298c7940304", "name": "load_p1rlv19149_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67a4600d-65c3-40d7-ad28-e8e37ff77dcb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "11b78b7d-430d-4a8d-bef5-0b834f29a3da"}}}}, {"uuid": "b126c6f7-d987-4d64-9271-4040e5e45fb2", "name": "411a8146-f899-45ca-9bf0-aab8e89c51e5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1deb3031-dd5d-4979-9be3-b3d7671c2f97", "name": "99cfbb7d-055c-4999-a3f9-841bc2001a22", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b126c6f7-d987-4d64-9271-4040e5e45fb2"}}}]}, {"uuid": "f7ecb440-0f55-4077-972a-53257e3a5828", "name": "load_p1rlv19149_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67a4600d-65c3-40d7-ad28-e8e37ff77dcb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1deb3031-dd5d-4979-9be3-b3d7671c2f97"}}}}, {"uuid": "2006ec6b-bb56-40ed-8a9f-8176087493fb", "name": "c814eae1-c780-4d8c-8f56-b953a77c46d9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9f955821-e89b-4b40-b4a1-6af5dd0b3574", "name": "8bc15210-bb12-457c-8ea0-0edd3dda432d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2006ec6b-bb56-40ed-8a9f-8176087493fb"}}}]}, {"uuid": "447a6f1f-7647-4dcf-9712-01fbb936a123", "name": "load_p1rlv19151_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e396aca-4116-40a0-8f17-bcd41f709ea5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9f955821-e89b-4b40-b4a1-6af5dd0b3574"}}}}, {"uuid": "c4fd19b7-b22f-46e5-b563-0298fb65e63c", "name": "ad996323-23ba-4d5d-b88c-159e5e2cbaaf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c137e1f1-bdbb-49ff-8f40-580b7e0f4224", "name": "ec44ced7-7c3c-4fde-b7fa-6b14d50146c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c4fd19b7-b22f-46e5-b563-0298fb65e63c"}}}]}, {"uuid": "c32a760d-f772-45ff-b58c-786f29590e79", "name": "load_p1rlv19151_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e396aca-4116-40a0-8f17-bcd41f709ea5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c137e1f1-bdbb-49ff-8f40-580b7e0f4224"}}}}, {"uuid": "c979f935-316d-4b43-8d51-0fae19c3ce1f", "name": "fa22fc25-8a81-4d5e-af8a-9ee320db2b53_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "99e06090-15dd-44ff-9d44-643acab3c309", "name": "f015c1fc-bc74-4fcb-a5c5-4c00e9b6e1a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c979f935-316d-4b43-8d51-0fae19c3ce1f"}}}]}, {"uuid": "67d5f06f-741f-4d64-8663-e91765b579ce", "name": "load_p1rlv19156_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7538ab85-10b4-4f60-98f8-179e954173b0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "99e06090-15dd-44ff-9d44-643acab3c309"}}}}, {"uuid": "63861aec-1ad6-4dff-a6b7-8e477408f934", "name": "266481a1-df1e-48ee-ab0c-e02cc76fe11c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5e21c6ee-1022-4216-8086-614971d8d0dc", "name": "bc1f8952-aa82-438a-b2de-7e231781adc7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "63861aec-1ad6-4dff-a6b7-8e477408f934"}}}]}, {"uuid": "9eccf85d-4195-48ef-b3e4-2066df60f2ca", "name": "load_p1rlv19156_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7538ab85-10b4-4f60-98f8-179e954173b0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5e21c6ee-1022-4216-8086-614971d8d0dc"}}}}, {"uuid": "ab78db94-1f0e-4dd7-83d1-9c218fb6c801", "name": "a4afcba3-8368-4025-a240-a48948785ede_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "03f0b66f-8782-437d-893c-4ab306535a7e", "name": "fd9b05bb-cd06-495e-ad6b-02b803e6ef0a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ab78db94-1f0e-4dd7-83d1-9c218fb6c801"}}}]}, {"uuid": "fb7b6520-f031-46e5-ab58-5a32c3720f76", "name": "load_p1rlv19157_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cf28b5d-d8d4-4883-a396-2d1ad9b70564"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "03f0b66f-8782-437d-893c-4ab306535a7e"}}}}, {"uuid": "4aec0a3d-5ed1-4d04-872b-4ea2c9a0270f", "name": "2b8246dc-5e8d-4877-b179-32172f58dbeb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.951523378781893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.458577423167183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "41a0cbe4-e162-4b07-8626-a429f97eb724", "name": "616828e3-a43b-4bd1-8729-bfc0edf8fea0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4aec0a3d-5ed1-4d04-872b-4ea2c9a0270f"}}}]}, {"uuid": "dfd1c368-60c2-4c49-a3d6-658df1829401", "name": "load_p1rlv19157_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cf28b5d-d8d4-4883-a396-2d1ad9b70564"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "41a0cbe4-e162-4b07-8626-a429f97eb724"}}}}, {"uuid": "656bb808-01e5-498d-b7e6-9d46d58c4339", "name": "e40be9cf-19b0-49f8-91cf-e7ed028086cb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cfb03cdd-df7b-4b87-835c-c55f81af6284", "name": "4b6fcb01-dac6-49ef-86a5-0aa8362e52c5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "656bb808-01e5-498d-b7e6-9d46d58c4339"}}}]}, {"uuid": "8b847b39-7e24-4032-b73b-2d85750c95c6", "name": "load_p1rlv19160_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7c1d210-ee87-46c5-b408-ad221cbeed04"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cfb03cdd-df7b-4b87-835c-c55f81af6284"}}}}, {"uuid": "204671b2-3428-47fe-846a-7027d0e70063", "name": "af954102-ced1-4ef2-aa4d-f783f34441d0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d77f185c-0a07-499e-94e4-504cda314ca5", "name": "355cf035-3998-4d46-9cef-82b52ea8b04f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "204671b2-3428-47fe-846a-7027d0e70063"}}}]}, {"uuid": "56a631ee-ab12-4070-82c8-c6afb5a609eb", "name": "load_p1rlv19160_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7c1d210-ee87-46c5-b408-ad221cbeed04"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d77f185c-0a07-499e-94e4-504cda314ca5"}}}}, {"uuid": "1257114c-fea5-441e-93ad-1e4d27afac16", "name": "5316039a-415e-4595-b908-92332fae7858_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c9e8216b-acd6-40a8-900a-1997fd54b543", "name": "a8fd5c09-0540-4cf1-96f7-2ccc4453783f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1257114c-fea5-441e-93ad-1e4d27afac16"}}}]}, {"uuid": "5e1657e0-b2a4-46b2-9af1-b71e3627f267", "name": "load_p1rlv19161_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16df6b90-d049-4160-b148-b888e03acb82"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c9e8216b-acd6-40a8-900a-1997fd54b543"}}}}, {"uuid": "29918bf7-fa41-4fc0-8435-78a1b354e19e", "name": "1dfbdde7-c939-48ca-ac88-d954a09977c3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8faaf976-ea71-4910-9243-aee1cb5d3875", "name": "90456313-14d1-4cfb-a466-8c19ad4da216", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "29918bf7-fa41-4fc0-8435-78a1b354e19e"}}}]}, {"uuid": "d570bd79-b4de-4cb4-b574-33abb71b1d14", "name": "load_p1rlv19161_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16df6b90-d049-4160-b148-b888e03acb82"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8faaf976-ea71-4910-9243-aee1cb5d3875"}}}}, {"uuid": "ba2ff638-568b-4237-b84f-6b8c4a91bc05", "name": "4cccfcec-862f-4664-bc65-7422e770750e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7930e8d4-bccc-4cf3-ae0f-3a50b581908a", "name": "b97340dc-d707-4767-8f8a-4206a3059695", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ba2ff638-568b-4237-b84f-6b8c4a91bc05"}}}]}, {"uuid": "4dfa51cb-050b-4616-880a-0ee67149a094", "name": "load_p1rlv19163_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fed6fcd4-3c97-4f62-a1a7-0b66394218e1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7930e8d4-bccc-4cf3-ae0f-3a50b581908a"}}}}, {"uuid": "b8d6d56e-9c72-4836-a2df-3cfa8013d452", "name": "7c3bf019-abfc-4bf4-8cf1-e4ee76528b6e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "78416a8d-5298-4100-90be-2e4fbc91d751", "name": "113e1321-cf95-47fb-9d92-56087fa014ad", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b8d6d56e-9c72-4836-a2df-3cfa8013d452"}}}]}, {"uuid": "f3f19601-292b-41de-af2e-8f3b1c6b0ae1", "name": "load_p1rlv19163_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fed6fcd4-3c97-4f62-a1a7-0b66394218e1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "78416a8d-5298-4100-90be-2e4fbc91d751"}}}}, {"uuid": "26aaa96b-786e-465c-a2d1-c8894affa276", "name": "de992046-31fd-456e-98b2-a83d9c206b75_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3913635530264314, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9282144314028667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aba50749-2a23-4445-9c0c-330d4aa4cf87", "name": "de992046-31fd-456e-98b2-a83d9c206b75_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3913635530264314, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9282144314028667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "717e806b-fad7-4a1d-916d-8b9115a4d843", "name": "de992046-31fd-456e-98b2-a83d9c206b75_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3913635530264314, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9282144314028667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b979ccd5-2f40-4746-a988-7df3e6b51ee6", "name": "c19c01a7-bb70-4fbf-a2ef-a87e599a4cc5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "26aaa96b-786e-465c-a2d1-c8894affa276"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aba50749-2a23-4445-9c0c-330d4aa4cf87"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "717e806b-fad7-4a1d-916d-8b9115a4d843"}}}]}, {"uuid": "3d93ef47-7f16-49ac-9061-3becf93bfb2e", "name": "load_p1rlv19164", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a02024b5-aa74-4e07-b043-a7a0e8b3e816"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b979ccd5-2f40-4746-a988-7df3e6b51ee6"}}}}, {"uuid": "44176e23-55fa-417c-9129-d715bc9d37e0", "name": "59d63d88-9fc3-472f-8ae1-7306b898b5b5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ff428f8c-2c3a-46ad-bb5b-4f6b3daa897a", "name": "793c4ce9-ef93-447c-969f-d8e370b4e3dc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "44176e23-55fa-417c-9129-d715bc9d37e0"}}}]}, {"uuid": "c19138fe-01ee-49cb-a8d6-b4871fe9a83d", "name": "load_p1rlv19165_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ebd10471-ab4c-4cb7-a822-a83ef20e9854"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ff428f8c-2c3a-46ad-bb5b-4f6b3daa897a"}}}}, {"uuid": "bd2d7e35-1845-408c-b298-02efde1b9cc8", "name": "30aadc1d-05e6-4d31-8f9e-392ba2a57f56_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5c200c50-9ade-4276-ac85-c37b94497797", "name": "4fe8aa86-072e-40d4-8c13-0a754e43967c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bd2d7e35-1845-408c-b298-02efde1b9cc8"}}}]}, {"uuid": "40f5f2ab-ba0c-40cb-bebf-3a82bfd0403b", "name": "load_p1rlv19165_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ebd10471-ab4c-4cb7-a822-a83ef20e9854"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5c200c50-9ade-4276-ac85-c37b94497797"}}}}, {"uuid": "db3a33cb-eb5f-4d19-8040-6ec5f2a248af", "name": "a0625715-56f8-4fdf-b453-3d7c15955b12_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c91b903a-179b-4b9c-8a91-ca04a45d4c0e", "name": "81bc24f8-de82-433f-8707-28c12fd0084a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "db3a33cb-eb5f-4d19-8040-6ec5f2a248af"}}}]}, {"uuid": "39bbf73a-53c6-4b2b-913c-1c0af0433c80", "name": "load_p1rlv19166_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "994f6392-f4e5-4ff8-9eeb-5849cd035912"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c91b903a-179b-4b9c-8a91-ca04a45d4c0e"}}}}, {"uuid": "8d2ed1ec-5a98-4037-90f6-92b438806eed", "name": "1094c4fe-7f5e-4bc1-a61c-0c9559c421da_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f285ff05-ecb6-4188-8db3-8a067e42b5ee", "name": "18649bc0-1baa-4dee-ab9d-f81face75a14", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8d2ed1ec-5a98-4037-90f6-92b438806eed"}}}]}, {"uuid": "07192b48-5d44-4d05-a633-d35c26bff647", "name": "load_p1rlv19166_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "994f6392-f4e5-4ff8-9eeb-5849cd035912"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f285ff05-ecb6-4188-8db3-8a067e42b5ee"}}}}, {"uuid": "51a86754-b9fd-4736-924c-c05f7f8f24cf", "name": "e0397dfc-2399-4620-a56c-99c8d416d2bc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6733980323267108, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22626974414284334, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50c4c48d-222e-4c54-8b4a-f763bdd5b7ce", "name": "44939ef2-1366-47f1-8979-9355dc7e84ee", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "51a86754-b9fd-4736-924c-c05f7f8f24cf"}}}]}, {"uuid": "e04e6f75-8d46-4726-bc92-bc890f422c32", "name": "load_p1rlv19168_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f8c76ca-40ea-4f7d-8042-66edd484f065"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50c4c48d-222e-4c54-8b4a-f763bdd5b7ce"}}}}, {"uuid": "f3bb7e45-84ac-4e2e-8c6c-125d4bcc1ede", "name": "a8ea18d3-c0a0-4561-80db-be47d3e3b27a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6733980323267108, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22626974414284334, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4e293a52-1321-43e4-986f-ff0fca24cd10", "name": "ebfa6fc3-90e8-4825-b481-5a41ede38177", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f3bb7e45-84ac-4e2e-8c6c-125d4bcc1ede"}}}]}, {"uuid": "29924464-4e3b-4d6c-9dcd-7a76c3a12c3c", "name": "load_p1rlv19168_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f8c76ca-40ea-4f7d-8042-66edd484f065"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4e293a52-1321-43e4-986f-ff0fca24cd10"}}}}, {"uuid": "96ad5f29-86ea-420a-a9cd-cbe7ca2e48eb", "name": "7db4b8c9-b98e-45ba-8a81-e9ce5bd4bb30_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0288569450045768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2608148575838028, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "23503b5a-e59b-4bb1-99f8-1e372e32a039", "name": "62c2d498-c75f-447d-8219-db50186f09b6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "96ad5f29-86ea-420a-a9cd-cbe7ca2e48eb"}}}]}, {"uuid": "e7dff548-5064-438a-a413-9aff670679b5", "name": "load_p1rlv19169_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4e8183-9148-477e-aa1b-ff31a5324273"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "23503b5a-e59b-4bb1-99f8-1e372e32a039"}}}}, {"uuid": "7386bf6b-5ea9-40f9-81d4-65cc62638403", "name": "4b60ec54-5e0c-4c8f-b177-4f0bffa4eab6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0288569450045768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2608148575838028, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b3b308a3-95f6-4303-ba39-ab01f40fb440", "name": "0a6d326f-8727-46a0-ac05-12991b041c50", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7386bf6b-5ea9-40f9-81d4-65cc62638403"}}}]}, {"uuid": "95cd4e39-549f-4256-bf1b-88f6a43ef741", "name": "load_p1rlv19169_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4e8183-9148-477e-aa1b-ff31a5324273"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b3b308a3-95f6-4303-ba39-ab01f40fb440"}}}}, {"uuid": "3e51eee4-c9b9-48b9-a509-6f5d3e28c164", "name": "ccaac138-77af-4e48-916d-b215032ae845_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9179777962446224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3481400399277513, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f5d6c979-9438-4c19-8522-4d45c399fcb9", "name": "88fa76d0-d740-4eb3-8795-a964b43c92f7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3e51eee4-c9b9-48b9-a509-6f5d3e28c164"}}}]}, {"uuid": "3f6ce2c3-d243-479a-a3f8-620a114cebfe", "name": "load_p1rlv19171_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fffe26f7-c4cc-420e-ab17-754cb0d9e659"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f5d6c979-9438-4c19-8522-4d45c399fcb9"}}}}, {"uuid": "d6c1250f-f71d-4f1a-bb72-14dfd31baa8a", "name": "16f46533-7fb7-48d6-a498-b14c5792acee_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9179777962446224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3481400399277513, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6a2bd906-7f88-4096-9f94-b57562a4e999", "name": "1226bbba-e446-4d18-ba7f-61609911329c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d6c1250f-f71d-4f1a-bb72-14dfd31baa8a"}}}]}, {"uuid": "5b046daf-851a-4c1b-bf0d-1ec757448c4d", "name": "load_p1rlv19171_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fffe26f7-c4cc-420e-ab17-754cb0d9e659"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6a2bd906-7f88-4096-9f94-b57562a4e999"}}}}, {"uuid": "f5c47ead-457b-4112-ad8c-4800362713a6", "name": "f3fed72c-794e-4ccf-bc98-1ddfbcffbf3e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2767849318619047, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.48605417385422345, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f0954b2-7595-4880-a85c-16379689a5a3", "name": "1f0ab7cf-00b3-4787-82dd-921330051fe0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f5c47ead-457b-4112-ad8c-4800362713a6"}}}]}, {"uuid": "de37a26e-d354-4d16-9ee2-102d49f9e97c", "name": "load_p1rlv19173_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21fec301-b67c-4042-a074-caf406c7f0b5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f0954b2-7595-4880-a85c-16379689a5a3"}}}}, {"uuid": "2755ca43-8485-4ee8-9f11-17dfc565e8b4", "name": "bf502988-57ea-4c56-817e-faeb9c732a97_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2767849318619047, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.48605417385422345, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "56afcfe9-dd5a-47a8-a53d-ba1dbef8cef0", "name": "c11a0f4c-9a5b-42bf-815d-2910e39bb476", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2755ca43-8485-4ee8-9f11-17dfc565e8b4"}}}]}, {"uuid": "fa66facc-d041-44f5-865d-955b3f553535", "name": "load_p1rlv19173_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21fec301-b67c-4042-a074-caf406c7f0b5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "56afcfe9-dd5a-47a8-a53d-ba1dbef8cef0"}}}}, {"uuid": "a8ae73b7-6e03-45d9-88de-409827be9cba", "name": "c2bd9970-2177-4852-a67c-9100fdfe36c5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4675207102133878, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42773122049615037, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b13a61e3-6de6-4b4d-ac19-c5e0a0b750b2", "name": "a98c29a4-7501-485a-9244-e39748d5e127", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a8ae73b7-6e03-45d9-88de-409827be9cba"}}}]}, {"uuid": "a0c7ea11-2c63-436f-879b-8ec104b8b6af", "name": "load_p1rlv19174_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0fc7d43-4f82-4100-99bf-6e30e03e95ce"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b13a61e3-6de6-4b4d-ac19-c5e0a0b750b2"}}}}, {"uuid": "fce4b9b9-ef25-43db-b488-7c2ccd0c63ed", "name": "827cf8ba-b9b6-4746-bab5-e2cecc2e9125_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4675207102133878, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42773122049615037, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7a4cae4e-d607-441d-8748-6f41ba771bd7", "name": "7fb7b1de-b694-4253-aed5-7dfb0b2b674f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fce4b9b9-ef25-43db-b488-7c2ccd0c63ed"}}}]}, {"uuid": "f84efad9-2336-4892-ac50-8af41feac531", "name": "load_p1rlv19174_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0fc7d43-4f82-4100-99bf-6e30e03e95ce"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7a4cae4e-d607-441d-8748-6f41ba771bd7"}}}}, {"uuid": "e654623f-313c-4b11-9315-ba6f2ef0b77e", "name": "dc4c20ae-4a63-412e-810d-23b4fd6c1190_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4660310317378347, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6643122913958558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "04555b76-290e-4556-b6b5-aa452336de03", "name": "c47057d9-5386-48fb-b604-4f93f2f5d2e1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e654623f-313c-4b11-9315-ba6f2ef0b77e"}}}]}, {"uuid": "061d6c99-a938-4855-b40a-9ef3068c8ecb", "name": "load_p1rlv19183_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "89bde057-807b-415c-9135-267c6bf43c44"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "04555b76-290e-4556-b6b5-aa452336de03"}}}}, {"uuid": "d0c2da70-16d4-4628-b508-621ecdfeeed0", "name": "c4771986-d8bf-440d-9b02-89deba7df031_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4660310317378347, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6643122913958558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6df221e1-7eb3-418c-ae30-18231f96db2c", "name": "4d7441d4-a0b8-4f87-a28f-9cc6381503b8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d0c2da70-16d4-4628-b508-621ecdfeeed0"}}}]}, {"uuid": "8ac36c2a-9eb2-4707-94ab-d7fed5c8d220", "name": "load_p1rlv19183_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "89bde057-807b-415c-9135-267c6bf43c44"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6df221e1-7eb3-418c-ae30-18231f96db2c"}}}}, {"uuid": "b079212d-2bdf-4bca-ae52-116cbe4167c7", "name": "860c4415-3bb1-4dc0-8a44-3322d4fe5bf7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.515259426400046, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4440975656599118, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3d8f19ec-f5a5-40d6-a2dd-707046dd3177", "name": "3c640dd5-a945-4231-8a4f-1bff34e77eb3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b079212d-2bdf-4bca-ae52-116cbe4167c7"}}}]}, {"uuid": "b6de3fac-4d6b-4a52-a9e2-e974cac85e5d", "name": "load_p1rlv19184_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50750ddb-80db-4d5f-bc62-4bbfc600a7ef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3d8f19ec-f5a5-40d6-a2dd-707046dd3177"}}}}, {"uuid": "75f6a9a4-4da0-4ec3-84b7-005556956265", "name": "89105886-e868-4927-8559-64821a385e04_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.515259426400046, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4440975656599118, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "efc0f742-5b1f-43a0-b2d4-5573c1a4d140", "name": "6e84dfc1-a870-431a-a07e-760ec8df0377", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "75f6a9a4-4da0-4ec3-84b7-005556956265"}}}]}, {"uuid": "971cc166-3ac8-4edc-b2a2-3530ffcaff58", "name": "load_p1rlv19184_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50750ddb-80db-4d5f-bc62-4bbfc600a7ef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "efc0f742-5b1f-43a0-b2d4-5573c1a4d140"}}}}, {"uuid": "754642c3-e803-4f34-baff-f09e25515573", "name": "baa45f2f-c3a6-49db-858a-ebdf21e7d73f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4040789998842194, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4565305929598704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5a7516eb-2e14-471b-b1a5-80ff03ee3fa7", "name": "d751e070-701e-4082-850e-878f679e40fa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "754642c3-e803-4f34-baff-f09e25515573"}}}]}, {"uuid": "66f572e4-3523-4380-9a62-0e30fd1a5db1", "name": "load_p1rlv19188_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47e24942-486d-46f1-a40f-0da5c93c013a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5a7516eb-2e14-471b-b1a5-80ff03ee3fa7"}}}}, {"uuid": "dad37bec-9b09-4868-9885-d2bcb994668d", "name": "32b1c83a-d83e-49c3-a245-2eeb2851a00a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4040789998842194, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4565305929598704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8014c6ba-e17d-4245-a9f8-48da6e5f0bd4", "name": "c16b5c3a-cb3c-48ec-80a5-95cc90f22f7b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dad37bec-9b09-4868-9885-d2bcb994668d"}}}]}, {"uuid": "e438f8bd-9345-4a19-a5dd-8239ac819ea3", "name": "load_p1rlv19188_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47e24942-486d-46f1-a40f-0da5c93c013a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8014c6ba-e17d-4245-a9f8-48da6e5f0bd4"}}}}, {"uuid": "7a9d7dc7-316b-40fa-b29f-90498d17c758", "name": "26b13717-8147-43cd-b52a-6d4b427ecf93_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.600795001494098, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2809795860066686, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eecd4421-78a7-416b-a3a3-deaf14e94d32", "name": "8205e059-91bc-4214-a0aa-c7c79f3147f7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7a9d7dc7-316b-40fa-b29f-90498d17c758"}}}]}, {"uuid": "1098ee10-5a4e-4a3c-b15d-d74068a9626a", "name": "load_p1rlv19189_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5fecc64a-4783-4ecb-a0d0-7e60d1cf6184"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eecd4421-78a7-416b-a3a3-deaf14e94d32"}}}}, {"uuid": "b052e304-473c-4eb4-860a-9a0bc656d98c", "name": "5d5bbf5b-4aec-4c9d-8284-8b9c4382b100_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.600795001494098, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2809795860066686, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7b3d9326-cef3-4965-890b-b628e4d53fec", "name": "754cf4af-6527-48c8-95e7-26b2c749a595", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b052e304-473c-4eb4-860a-9a0bc656d98c"}}}]}, {"uuid": "7473f293-ed7f-4335-bafc-5a15171814ac", "name": "load_p1rlv19189_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5fecc64a-4783-4ecb-a0d0-7e60d1cf6184"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7b3d9326-cef3-4965-890b-b628e4d53fec"}}}}, {"uuid": "00b124f3-cc84-430f-97a4-73423875313a", "name": "ceee5312-17ae-4fbf-b3d8-9867944bd18c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0490448796184286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8093782533373945, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "afbf58b1-8dca-4241-b36b-51ca85dc011d", "name": "2a4fd228-46cf-41a5-9624-030a18ec5c56", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "00b124f3-cc84-430f-97a4-73423875313a"}}}]}, {"uuid": "7a57a2de-df82-4671-9dcd-3f69ee3acdfb", "name": "load_p1rlv19190_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4aee02d4-8663-455b-a197-55b6b1470895"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "afbf58b1-8dca-4241-b36b-51ca85dc011d"}}}}, {"uuid": "04f380b5-c1ee-4699-8ded-bef9e45c57bb", "name": "857dc4d5-e612-450a-a93b-fa84a87f8f28_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0490448796184286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8093782533373945, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "006b69f8-f94f-41c8-87f5-22b2ee2e8765", "name": "d9ddc10a-cf53-4859-9d95-35c61f4addc0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "04f380b5-c1ee-4699-8ded-bef9e45c57bb"}}}]}, {"uuid": "7f756e00-95e8-4749-99b7-6533fb0bc45e", "name": "load_p1rlv19190_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4aee02d4-8663-455b-a197-55b6b1470895"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "006b69f8-f94f-41c8-87f5-22b2ee2e8765"}}}}, {"uuid": "7ed29888-5e04-490f-aa78-e62dd67093f3", "name": "a040e458-a970-4c7d-9686-89d2fcbe69ff_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7073298240395912, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.27247283022117846, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a0042c48-29f7-4122-9d41-8e1b226a1fa2", "name": "684f1f72-1aed-481a-bd57-43848c78bb39", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7ed29888-5e04-490f-aa78-e62dd67093f3"}}}]}, {"uuid": "5a6858d9-dc19-4959-bfe2-02bb18b2bb2f", "name": "load_p1rlv19194_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7daa1d3-6249-447d-a260-65de5ec0a470"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a0042c48-29f7-4122-9d41-8e1b226a1fa2"}}}}, {"uuid": "f3072aaf-be87-40e4-84fc-c06c6ea3506e", "name": "a7671389-ac45-4876-be86-4ad168ed35a0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7073298240395912, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.27247283022117846, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ed4e9771-7f88-46a3-a65f-5a9bd2944670", "name": "14dcf3fc-3c25-4d56-801f-913d72d024fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f3072aaf-be87-40e4-84fc-c06c6ea3506e"}}}]}, {"uuid": "bfd4db25-0215-426a-b567-04a4ac298abd", "name": "load_p1rlv19194_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7daa1d3-6249-447d-a260-65de5ec0a470"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ed4e9771-7f88-46a3-a65f-5a9bd2944670"}}}}, {"uuid": "3e86aca5-6aab-4f92-ae50-2bddbb36e1be", "name": "af904d00-c1d6-47a9-8edc-0af7c25654b2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5757409771642927, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7652901499575055, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d9809f00-acc3-4d7e-9b89-1477725e87a3", "name": "e0954155-7e81-40da-9db5-b2d1b498ce7a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3e86aca5-6aab-4f92-ae50-2bddbb36e1be"}}}]}, {"uuid": "eac7a319-9e7b-4f16-ad17-ce684bc7550d", "name": "load_p1rlv19667_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33dcb037-4cc8-480f-aac4-bc95e54e165e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d9809f00-acc3-4d7e-9b89-1477725e87a3"}}}}, {"uuid": "ccde68f5-b039-4bda-ae4c-9efd64edbf23", "name": "b40bf064-50a2-4e66-a1e0-0d7e208df0bc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5757409771642927, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7652901499575055, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d5d225fe-1f02-44a7-9290-99e5d55a6faa", "name": "c8517da0-0aae-4d9e-80d3-b8b25f936384", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ccde68f5-b039-4bda-ae4c-9efd64edbf23"}}}]}, {"uuid": "159a267b-a341-462f-af3b-8d2fa2d7a9d3", "name": "load_p1rlv19667_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33dcb037-4cc8-480f-aac4-bc95e54e165e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d5d225fe-1f02-44a7-9290-99e5d55a6faa"}}}}, {"uuid": "ea589c8f-cc85-4486-a172-dcfb51a011cf", "name": "6ff93963-157c-49bf-808e-721b4befa146_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.539100612527363, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.549143952601146, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ae4c2fae-3337-426c-b97e-93002c961cff", "name": "f70c2f5e-b770-488a-ac4d-23d574d34886", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ea589c8f-cc85-4486-a172-dcfb51a011cf"}}}]}, {"uuid": "dd60ac8b-a84d-40ba-9706-2eefe88e3183", "name": "load_p1rlv19668_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6427f66-2e22-40bb-83f1-2a8b1be9191a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ae4c2fae-3337-426c-b97e-93002c961cff"}}}}, {"uuid": "ef8495a0-4d6b-4995-9400-667c6fe969bb", "name": "9f15c2b1-07cb-41d4-84c2-b17acd8dffbf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.539100612527363, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.549143952601146, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c6c85d9c-f0c9-47a9-9a63-ed573637a24e", "name": "c979cb7e-77c5-47f1-b96d-fba1ec56a04b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ef8495a0-4d6b-4995-9400-667c6fe969bb"}}}]}, {"uuid": "4e059a4d-2a38-4306-845c-491ec42a2875", "name": "load_p1rlv19668_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6427f66-2e22-40bb-83f1-2a8b1be9191a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c6c85d9c-f0c9-47a9-9a63-ed573637a24e"}}}}, {"uuid": "f27f007c-2e11-4bdb-bb7e-100621d0bc49", "name": "44437314-92d0-4a62-9834-4fb8eaae5d2e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4037437915385973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5086059213404144, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b949ff1c-0f56-4d40-a461-22cc4cdac93d", "name": "8bae368a-487c-4de4-831a-d8fc546f342b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f27f007c-2e11-4bdb-bb7e-100621d0bc49"}}}]}, {"uuid": "8a5023e4-c0f5-44a0-a855-3398bd2dc9c9", "name": "load_p1rlv19669_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96d3079a-02f1-4c89-ad75-fd0a438c9cf4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b949ff1c-0f56-4d40-a461-22cc4cdac93d"}}}}, {"uuid": "d33f15fc-edf5-4bfa-a3d5-74552ed68265", "name": "61b541aa-9206-4840-ac4f-706ef534c1f5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4037437915385973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5086059213404144, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "117008e9-c0bf-4cc9-b860-289a2d757b15", "name": "8a0f45ea-92a7-4798-8d8f-ebe97c55be71", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d33f15fc-edf5-4bfa-a3d5-74552ed68265"}}}]}, {"uuid": "a21aa7c8-8062-4e99-a92d-1883e14314dc", "name": "load_p1rlv19669_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96d3079a-02f1-4c89-ad75-fd0a438c9cf4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "117008e9-c0bf-4cc9-b860-289a2d757b15"}}}}, {"uuid": "2603ec16-0540-4eeb-a2cd-701568cc54c0", "name": "179e0570-a4a0-4b27-babd-3f4c9ccc0700_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.308477864741614, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307751830484037, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bb9e05e9-b83a-4c56-868c-c22d46686968", "name": "ccb173c5-314b-446f-99a3-56f5a6f88a2e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2603ec16-0540-4eeb-a2cd-701568cc54c0"}}}]}, {"uuid": "10d06a86-24d8-43c3-be81-9e7524c167b8", "name": "load_p1rlv19675_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0031ab1b-d82d-40a5-b41e-bc6f6cb53069"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bb9e05e9-b83a-4c56-868c-c22d46686968"}}}}, {"uuid": "19e75e2a-07c5-4b8d-9791-c5f455991a2b", "name": "eeea6a3d-a27e-466c-b070-2ecd8d446e1f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.308477864741614, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307751830484037, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d7ca90cb-332d-4801-bedc-06caa0a9d9b9", "name": "69c8d922-d412-4b91-aa6a-1c77f7b1828a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "19e75e2a-07c5-4b8d-9791-c5f455991a2b"}}}]}, {"uuid": "d2997514-1651-4b24-9fbe-70e223296d34", "name": "load_p1rlv19675_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0031ab1b-d82d-40a5-b41e-bc6f6cb53069"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d7ca90cb-332d-4801-bedc-06caa0a9d9b9"}}}}, {"uuid": "3a9b348e-e778-4211-801f-9e6f1d945b9c", "name": "9930f8d0-e7ac-478b-a9f3-6b79645baaaa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4359784649582454, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.14838741475370543, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f5ab5822-1abe-4c20-b73a-0de7d7ba03a1", "name": "ef801244-6147-4689-a91b-878c0eaf26d9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3a9b348e-e778-4211-801f-9e6f1d945b9c"}}}]}, {"uuid": "ad50bdea-72ac-428a-acdf-166a01d5d7af", "name": "load_p1rlv19681_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83afc678-d577-4ef1-afa2-8e3f915a158b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f5ab5822-1abe-4c20-b73a-0de7d7ba03a1"}}}}, {"uuid": "59538ed4-fede-470a-822f-3b8d98eb3227", "name": "29f77274-9da6-4ea5-a124-b6f948542cf6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4359784649582454, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.14838741475370543, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0338d20b-ad9a-42c7-8b29-7ed52185693a", "name": "4a81538b-7048-42c6-b044-9669b84e90c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "59538ed4-fede-470a-822f-3b8d98eb3227"}}}]}, {"uuid": "b3a4b610-473d-4d59-9f38-1d36ac630f13", "name": "load_p1rlv19681_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83afc678-d577-4ef1-afa2-8e3f915a158b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0338d20b-ad9a-42c7-8b29-7ed52185693a"}}}}, {"uuid": "d1d0c3a6-4a7f-400b-a363-43c849f9c524", "name": "66047564-508a-4cec-b8ce-63f7ef123416_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4849313480010438, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7277224910757479, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "77941e17-d559-4b1f-b3a3-600923300a63", "name": "3935ff4f-cb25-4218-b2e7-8cd01e2a9328", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d1d0c3a6-4a7f-400b-a363-43c849f9c524"}}}]}, {"uuid": "10735e5a-5755-40a0-8e82-1d583800ddcd", "name": "load_p1rlv19682_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "811acd48-b61c-4a42-b76e-f995961c450e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "77941e17-d559-4b1f-b3a3-600923300a63"}}}}, {"uuid": "fe7d7d58-2846-4202-8450-e78c57fe55f0", "name": "67b3f1c5-2afe-4529-a0f5-ef4b9c245518_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4849313480010438, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7277224910757479, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "42a267db-803a-4bc8-a40d-d8ab8ee7b199", "name": "7fc602c6-9be3-4295-b436-83f2fc0ea5e2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fe7d7d58-2846-4202-8450-e78c57fe55f0"}}}]}, {"uuid": "53946547-2e1c-4c77-a55f-c649d926f97d", "name": "load_p1rlv19682_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "811acd48-b61c-4a42-b76e-f995961c450e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "42a267db-803a-4bc8-a40d-d8ab8ee7b199"}}}}, {"uuid": "d26bc30f-0158-4c51-917f-c60ce491b3fb", "name": "b8d0cf34-a770-4338-910b-adc97ba3d421_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2440101223346245, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10648703060010346, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1acdbbdd-5dcb-4b9e-9a4e-5bc71457e53d", "name": "a127345d-9a3b-48db-bf79-acbad49eb2aa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d26bc30f-0158-4c51-917f-c60ce491b3fb"}}}]}, {"uuid": "1ed25cf3-552c-44cd-b511-1701113ba3c8", "name": "load_p1rlv19686_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47f5777d-2c8d-48c2-bf28-386f3f3dbac4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1acdbbdd-5dcb-4b9e-9a4e-5bc71457e53d"}}}}, {"uuid": "af93eee8-f9bb-442b-a583-01f70afd4be2", "name": "6d593d1f-33a6-427a-b162-895b1023099a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2440101223346245, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10648703060010346, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "65e22d17-96fc-4665-886e-7e790749b309", "name": "303f0c22-2214-43e0-8822-e0bf37a2d074", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "af93eee8-f9bb-442b-a583-01f70afd4be2"}}}]}, {"uuid": "edfb7a27-0781-491e-8b2c-05146ed035ea", "name": "load_p1rlv19686_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47f5777d-2c8d-48c2-bf28-386f3f3dbac4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "65e22d17-96fc-4665-886e-7e790749b309"}}}}, {"uuid": "8a3bd121-0a2f-44af-8082-f24496c7efe4", "name": "048758ca-e638-4bfd-8d21-93557dbc8592_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.895690985965537, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9400572249599172, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "80125096-6207-409a-b0d9-669647c2319a", "name": "08ab45e8-b3a6-4390-a198-d173f57dec21", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a3bd121-0a2f-44af-8082-f24496c7efe4"}}}]}, {"uuid": "5305c7c6-d109-4a09-b2a2-f92de08df8bd", "name": "load_p1rlv19689_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "578b5df8-1dd8-41d9-b6dc-db75db5b115e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "80125096-6207-409a-b0d9-669647c2319a"}}}}, {"uuid": "69ac157c-6e9f-4962-b7cd-69c3655c9828", "name": "bc38a9b4-53f4-432b-a1d0-61ccee37928b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.895690985965537, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9400572249599172, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "43567337-5bcb-4f0c-8318-114fb73d774a", "name": "b7bfa72b-5be3-4ee8-98c8-62cfb2e5ba89", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "69ac157c-6e9f-4962-b7cd-69c3655c9828"}}}]}, {"uuid": "54029791-40d2-46d2-b363-b156e77814c3", "name": "load_p1rlv19689_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "578b5df8-1dd8-41d9-b6dc-db75db5b115e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "43567337-5bcb-4f0c-8318-114fb73d774a"}}}}, {"uuid": "c165eb8f-b5a6-4e6d-9104-35e132a992cc", "name": "c3532b3a-9e3e-417c-9ee3-307cd4b961fd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.308477864741614, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307751830484037, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1b649937-0e7f-494f-b253-419d69e74bab", "name": "76d649ac-cd9e-4f5c-8296-c2ba742698b1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c165eb8f-b5a6-4e6d-9104-35e132a992cc"}}}]}, {"uuid": "c66fa230-0cb1-48ff-ae1e-b329cd193928", "name": "load_p1rlv19690_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2709a70-1a7d-454c-90fd-377e416a0071"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1b649937-0e7f-494f-b253-419d69e74bab"}}}}, {"uuid": "4e74008a-5710-4b3a-b8df-8f73b24776d4", "name": "0347b171-ddc6-480b-8f2e-881491975645_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.308477864741614, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307751830484037, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8b8100cd-4d06-4016-874c-663fb29a2a84", "name": "e0c941a5-31a2-43c6-8d2c-7bab3fe96d52", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4e74008a-5710-4b3a-b8df-8f73b24776d4"}}}]}, {"uuid": "f5b02566-069f-4c58-a0a6-5eed94d9e47c", "name": "load_p1rlv19690_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2709a70-1a7d-454c-90fd-377e416a0071"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8b8100cd-4d06-4016-874c-663fb29a2a84"}}}}, {"uuid": "77165c56-c89d-4ebb-ad57-9b1e28126383", "name": "48fa7aea-32e0-4c8a-bbd1-1cebf6f5d9b6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5901541038441702, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.07457634724192848, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fc34bb05-87f4-4799-a01d-3927f582bcd6", "name": "34f24218-15e1-4f5c-9d09-301a0c1f76cb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "77165c56-c89d-4ebb-ad57-9b1e28126383"}}}]}, {"uuid": "9b820f03-083c-4edf-81ea-27dfe2aee5e5", "name": "load_p1rlv19691_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "604cb559-0f18-4ef7-8bcd-a07a7e7f96d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fc34bb05-87f4-4799-a01d-3927f582bcd6"}}}}, {"uuid": "3a4a5f53-1e04-402a-a6db-3045fa896c82", "name": "788da8c3-0c69-4a0a-8924-972af172aebf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5901541038441702, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.07457634724192848, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "58a9b220-c202-49b7-be70-961245a29423", "name": "05b00e44-bc66-4e6e-a026-9cdc0e5901ac", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3a4a5f53-1e04-402a-a6db-3045fa896c82"}}}]}, {"uuid": "88111d81-0056-4c62-8fa1-ad8367b8b2d7", "name": "load_p1rlv19691_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "604cb559-0f18-4ef7-8bcd-a07a7e7f96d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "58a9b220-c202-49b7-be70-961245a29423"}}}}, {"uuid": "cf87f2b7-175d-4ce8-84c5-e47d6819cd32", "name": "f611a5d7-dea6-405a-9320-609bc39ca2c3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.424079283052672, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.088828085193726, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "28d0d815-3de0-490c-94ae-4c4fa92969da", "name": "f40f87e8-d79c-4aea-a77f-fe8f67002d74", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cf87f2b7-175d-4ce8-84c5-e47d6819cd32"}}}]}, {"uuid": "620421db-9084-49f1-afa1-15b5180d2e9d", "name": "load_p1rlv19692_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b10b272a-2efb-4e19-9921-d4081fb45778"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "28d0d815-3de0-490c-94ae-4c4fa92969da"}}}}, {"uuid": "6201eba7-27e1-4bfa-9236-6be455ae382f", "name": "874ea8ba-2e4a-4758-8910-ffb5aba63a6d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.424079283052672, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.088828085193726, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8fc451d1-1b3a-4027-b6e4-5ab4e353ac33", "name": "c428ca70-9ec6-42e4-9498-df2ce9a9ac01", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6201eba7-27e1-4bfa-9236-6be455ae382f"}}}]}, {"uuid": "89953e12-96e9-494d-a5bc-45969cf03417", "name": "load_p1rlv19692_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b10b272a-2efb-4e19-9921-d4081fb45778"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8fc451d1-1b3a-4027-b6e4-5ab4e353ac33"}}}}, {"uuid": "3e120d1d-e367-4433-8b5c-5cfa4c05bfc7", "name": "c623f11b-f702-4be1-b6b2-d417ae367f0e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.01164824929789, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.30321095330991316, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8e3290d6-521b-4a69-9aa7-a5478a53a9a7", "name": "54f4d3c8-6a3a-4744-a32c-5dacea40d4b8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3e120d1d-e367-4433-8b5c-5cfa4c05bfc7"}}}]}, {"uuid": "98a8d7ce-fa0d-4b53-b172-4c1b6aba6bf7", "name": "load_p1rlv19695_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35fe21a1-f817-426e-9e42-f1f33876dd7d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8e3290d6-521b-4a69-9aa7-a5478a53a9a7"}}}}, {"uuid": "eec4bf16-f1ed-4404-8554-8574940fe947", "name": "272ae202-08fa-4d80-839a-9a3080a1e95f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.01164824929789, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.30321095330991316, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7f95e30e-ea29-451d-87fb-c069d649283a", "name": "6493fce6-8465-4769-9eee-2221707dc58f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eec4bf16-f1ed-4404-8554-8574940fe947"}}}]}, {"uuid": "c20c99cb-c78e-4ae5-aa2e-2accbced38cf", "name": "load_p1rlv19695_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35fe21a1-f817-426e-9e42-f1f33876dd7d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7f95e30e-ea29-451d-87fb-c069d649283a"}}}}, {"uuid": "f145327e-2162-42b6-8a11-26b2bfde7600", "name": "a9857ff6-34b2-4ec8-843b-b4f93dab0a28_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.445994317964332, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8597073331859654, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0c3432cf-d00e-420c-ad29-b45eceacc58a", "name": "632e3014-86c5-401b-9e6a-ea8235b3a564", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f145327e-2162-42b6-8a11-26b2bfde7600"}}}]}, {"uuid": "e7c985a2-dd3e-4ea6-a120-8c6d8e866d63", "name": "load_p1rlv19698_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14b1ab4e-b22d-4a98-8131-fc72c923c735"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0c3432cf-d00e-420c-ad29-b45eceacc58a"}}}}, {"uuid": "b8c806b8-d2d3-4b6e-9b57-3cb8b968f85c", "name": "d51b1bd3-7852-492c-a51e-5ca1e90b38b4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.445994317964332, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8597073331859654, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6354f900-88a1-49f8-bd70-306ee4e16e14", "name": "0a0e1126-55ca-455d-8658-67827e307025", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b8c806b8-d2d3-4b6e-9b57-3cb8b968f85c"}}}]}, {"uuid": "a9fe8784-2888-44a7-afa3-24d828418cda", "name": "load_p1rlv19698_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14b1ab4e-b22d-4a98-8131-fc72c923c735"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6354f900-88a1-49f8-bd70-306ee4e16e14"}}}}, {"uuid": "f317c62a-0a34-4e0b-bffb-508a05b0080c", "name": "162071be-39d3-423a-9165-bfd64e018cd2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4663769608466568, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5502546109327153, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fc82c7e2-b64e-46ce-ac11-0609a93d3242", "name": "ca1e6878-747f-48b5-aafb-2e7baf793657", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f317c62a-0a34-4e0b-bffb-508a05b0080c"}}}]}, {"uuid": "888dbe4f-cd30-4381-bcec-a643f2c74829", "name": "load_p1rlv19699_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48654a82-ac11-4542-94ec-8f731138e1a8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fc82c7e2-b64e-46ce-ac11-0609a93d3242"}}}}, {"uuid": "462bcf4f-c7e0-42f4-b852-f1a30a0b2a49", "name": "678cde70-2782-44ef-94fa-676fc2adb482_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4663769608466568, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5502546109327153, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cf65c499-b81c-4756-b5fc-cb82c815f025", "name": "f57da8ee-9669-44e5-b79d-404a52a01290", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "462bcf4f-c7e0-42f4-b852-f1a30a0b2a49"}}}]}, {"uuid": "fbe73a3c-692a-4ac9-851d-923425420048", "name": "load_p1rlv19699_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48654a82-ac11-4542-94ec-8f731138e1a8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cf65c499-b81c-4756-b5fc-cb82c815f025"}}}}, {"uuid": "179a4141-de77-4c08-a44c-94bc38111e71", "name": "b8edef17-753c-4640-ac88-234b59bd56b6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.331677082668279, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10958157805626084, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "de6c7d43-35c0-417e-9fbd-95f4c1c8135d", "name": "757edf94-1466-40b6-96a7-ca913b133456", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "179a4141-de77-4c08-a44c-94bc38111e71"}}}]}, {"uuid": "4e5e96cb-f1a5-43fa-93cb-23867576491d", "name": "load_p1rlv19701_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b5d936f-b3e0-408e-aabd-d3ebb7b869b0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "de6c7d43-35c0-417e-9fbd-95f4c1c8135d"}}}}, {"uuid": "240b3ec9-bc79-4c17-a8ee-8a8a425aa703", "name": "a68403b6-c7d7-45d0-83a6-4cfb97dc1f03_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.331677082668279, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10958157805626084, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c529a6f8-27f2-45db-aa1e-b8735c436127", "name": "928f825a-6ba2-4c81-a7c3-16861b88d2fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "240b3ec9-bc79-4c17-a8ee-8a8a425aa703"}}}]}, {"uuid": "51fa4197-1ba0-4eb2-b976-cb70045c9dfc", "name": "load_p1rlv19701_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b5d936f-b3e0-408e-aabd-d3ebb7b869b0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c529a6f8-27f2-45db-aa1e-b8735c436127"}}}}, {"uuid": "156a0ac9-458f-4c46-a04e-17ab1c6a23b4", "name": "932c9135-e467-4500-aee5-e3c7f125befa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 10.082274628538993, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.081607403669262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "326677db-6a41-4e8b-980e-90d10d1b78e7", "name": "60006b6a-3bcf-4371-a609-3fc2fb90e38a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "156a0ac9-458f-4c46-a04e-17ab1c6a23b4"}}}]}, {"uuid": "f9d708c9-eff7-4751-bcfa-65f0229b06c6", "name": "load_p1rlv19702_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37f72c85-61f7-4a42-94b0-6a627195458c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "326677db-6a41-4e8b-980e-90d10d1b78e7"}}}}, {"uuid": "42ff104e-d487-488b-8198-ae0df3abe8a3", "name": "6210e0b1-6210-4b7e-ab87-a9bed2bc7dc2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 10.082274628538993, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.081607403669262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0bdc9d7e-fba8-49d4-9a57-658e2eb6cdd9", "name": "c227d2e3-0c90-4d1c-8c71-cc21d84664af", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "42ff104e-d487-488b-8198-ae0df3abe8a3"}}}]}, {"uuid": "6c4ddb26-7f82-4578-95a1-80c652ba322a", "name": "load_p1rlv19702_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37f72c85-61f7-4a42-94b0-6a627195458c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0bdc9d7e-fba8-49d4-9a57-658e2eb6cdd9"}}}}, {"uuid": "3184dfb6-fe85-425b-8a2c-c8fcabee3cd9", "name": "434fc340-de1b-4a82-8747-2248052d2c85_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3786182488338723, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5359363058124609, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b2355f90-4b19-4f76-80f4-adbeb95f2861", "name": "e61cb651-ad75-433a-9e9b-e9b2fda0facc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3184dfb6-fe85-425b-8a2c-c8fcabee3cd9"}}}]}, {"uuid": "dd16986e-9178-4da5-94b5-abcd4a1cc80e", "name": "load_p1rlv20064_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aaea76fa-797e-46c5-a70f-a973977db841"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b2355f90-4b19-4f76-80f4-adbeb95f2861"}}}}, {"uuid": "3feb125e-0d30-4fa3-82b5-0a90a68f4f14", "name": "875ba8f6-e4f4-4981-89ed-f27d39ef2d03_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3786182488338723, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5359363058124609, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "faf06bc4-7f26-4a7b-981a-687b60237334", "name": "d62f7ca0-6d08-4cd6-8386-a2ad5803c0a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3feb125e-0d30-4fa3-82b5-0a90a68f4f14"}}}]}, {"uuid": "57d2795d-d45e-4749-ac18-4571bed715e7", "name": "load_p1rlv20064_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aaea76fa-797e-46c5-a70f-a973977db841"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "faf06bc4-7f26-4a7b-981a-687b60237334"}}}}, {"uuid": "697fca7f-f900-4399-9c9d-b7205ca2b896", "name": "1d1f1f6b-373d-428a-802b-e75f3af3d344_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9024769844937937, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4778358547008617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c89f6f9b-6be1-4081-a28f-ed71a35d83d4", "name": "81dd230b-be00-4e12-8599-9ff89e8d8aeb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "697fca7f-f900-4399-9c9d-b7205ca2b896"}}}]}, {"uuid": "f79d6824-33e0-4ddd-951e-c7a5dac2dc56", "name": "load_p1rlv20065_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea48ffa1-bdb3-4c15-96c9-ff7d7f34824f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c89f6f9b-6be1-4081-a28f-ed71a35d83d4"}}}}, {"uuid": "ad82f3f6-4fb0-493e-93e1-77619dfd382d", "name": "3e63e9a2-9263-49c9-8ce1-3b47b443769f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9024769844937937, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4778358547008617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "73056679-3214-4d0f-83d7-ea183b641d86", "name": "bbc86f6c-acca-45bc-b5c8-5c8e39c6bde2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ad82f3f6-4fb0-493e-93e1-77619dfd382d"}}}]}, {"uuid": "3fa11059-f23c-4332-afc5-f519c6bc4dfa", "name": "load_p1rlv20065_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea48ffa1-bdb3-4c15-96c9-ff7d7f34824f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "73056679-3214-4d0f-83d7-ea183b641d86"}}}}, {"uuid": "82613dda-2b0e-4576-ae18-3bae3f4b0bc1", "name": "12d6d0c1-1c78-4fba-80b4-98cd493320f6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9149869461814677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5767582022429075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "785fa984-c159-4e43-95ba-4838988535f5", "name": "33e33e39-b784-4951-a35e-45fe11e0de3a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "82613dda-2b0e-4576-ae18-3bae3f4b0bc1"}}}]}, {"uuid": "c8b6dbe3-fffb-47f6-b40d-5d02da5b6d2b", "name": "load_p1rlv20066_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f450eeb4-3d87-4ae5-a6d6-958d7efd2712"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "785fa984-c159-4e43-95ba-4838988535f5"}}}}, {"uuid": "173dc49f-cf27-46a6-9b3c-0c661da60210", "name": "5bc0a30a-237a-4fd5-8bc2-85472c196b45_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9149869461814677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5767582022429075, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f540a76d-b5bb-431a-b2f2-50d5e78ab247", "name": "378ad036-0bbd-4070-b526-a3133b72d989", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "173dc49f-cf27-46a6-9b3c-0c661da60210"}}}]}, {"uuid": "db1b57aa-7de9-440d-883d-9651cdeae0a4", "name": "load_p1rlv20066_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f450eeb4-3d87-4ae5-a6d6-958d7efd2712"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f540a76d-b5bb-431a-b2f2-50d5e78ab247"}}}}, {"uuid": "2e8cf59c-6701-435e-8544-46ba106c78c7", "name": "8033911c-8184-4264-a0e0-42e5f03c32bf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1800d4d6-8a1e-44bf-ad2f-c6feda9f0b59", "name": "d8ec233b-e55b-463f-83ae-b0ae42abe0e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2e8cf59c-6701-435e-8544-46ba106c78c7"}}}]}, {"uuid": "1e865edd-ffaa-43ba-8b6e-a1d20c8ff803", "name": "load_p1rlv20067_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66a710fb-26c7-4465-b7ea-43ec107008dc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1800d4d6-8a1e-44bf-ad2f-c6feda9f0b59"}}}}, {"uuid": "92818016-ab6d-4337-8604-dcd511bd4151", "name": "2b659a4c-5e5c-44b8-96c0-52aac0b9da6c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a6c90a3d-94da-42ea-be63-43fde770dfde", "name": "f4b0e80f-9d14-4c13-8d38-047e9c58748d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "92818016-ab6d-4337-8604-dcd511bd4151"}}}]}, {"uuid": "7b858e2b-5879-4899-adc7-9d076a7f0ef4", "name": "load_p1rlv20067_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66a710fb-26c7-4465-b7ea-43ec107008dc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a6c90a3d-94da-42ea-be63-43fde770dfde"}}}}, {"uuid": "7677d201-3380-417a-9a52-9ef8fa9dfee1", "name": "63199bcf-5a1a-47bc-8d0a-44308165240b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9909c8b7-5b23-4575-9321-50732255db2a", "name": "3b9e654b-3b09-4b7c-b5b8-3f4660f31a85", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7677d201-3380-417a-9a52-9ef8fa9dfee1"}}}]}, {"uuid": "4152a1b5-d3f7-42db-9171-67392eaf7efd", "name": "load_p1rlv20068_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0b689f0-d4b1-4419-bff8-f72436625c60"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9909c8b7-5b23-4575-9321-50732255db2a"}}}}, {"uuid": "3e63513a-bb72-4d31-a2f9-70ec25c0b612", "name": "9b4bfbff-5ae6-4715-abfa-3af5790cc2d2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8943da66-5e87-482c-b323-437b555f1300", "name": "e7d84638-533e-4bd0-ae06-10a0dd73c4ab", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3e63513a-bb72-4d31-a2f9-70ec25c0b612"}}}]}, {"uuid": "3a0d0e67-4e45-466a-a48b-e5f651e188f6", "name": "load_p1rlv20068_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0b689f0-d4b1-4419-bff8-f72436625c60"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8943da66-5e87-482c-b323-437b555f1300"}}}}, {"uuid": "5605eca0-70bb-4c8b-956a-95ff334d8a43", "name": "f301133a-2df9-4eaf-80fe-f3b6c5d7880f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4037437915385973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5086059213404144, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "273da72e-70f8-4e20-b811-1d5aa8ac1840", "name": "f6722d02-839c-40da-add4-3dd5022b89e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5605eca0-70bb-4c8b-956a-95ff334d8a43"}}}]}, {"uuid": "efba0dc4-178b-4e97-82ec-7abb378997a4", "name": "load_p1rlv20069_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f0e3c74-2d63-4612-b0e5-d986ebee0086"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "273da72e-70f8-4e20-b811-1d5aa8ac1840"}}}}, {"uuid": "d8cb5421-7324-4513-b981-cd8ecdbea96f", "name": "27462fda-ccf8-499d-9b18-ca37ec941ee7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4037437915385973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5086059213404144, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1988d2a9-1029-4430-9f27-d5a16a35948c", "name": "9e4309a5-8321-4913-b06e-df37e6c2ff78", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d8cb5421-7324-4513-b981-cd8ecdbea96f"}}}]}, {"uuid": "398b0ec5-319c-4b3a-acb2-211ad4bd8015", "name": "load_p1rlv20069_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f0e3c74-2d63-4612-b0e5-d986ebee0086"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1988d2a9-1029-4430-9f27-d5a16a35948c"}}}}, {"uuid": "3ba36142-8efd-4af0-aabe-3d6c4e896e98", "name": "19143221-bbf3-412f-a922-844fb1f84b47_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1342890945582846, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10427649324668606, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4beddc3f-4f50-4de9-98bd-a0a3c47d55bb", "name": "420dc19a-c423-4269-929b-8e02f608bb34", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3ba36142-8efd-4af0-aabe-3d6c4e896e98"}}}]}, {"uuid": "ea4428f7-8e83-4552-88eb-60da17163578", "name": "load_p1rlv20070_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "571a4c92-95b6-4bc0-a25d-0d9239a41a89"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4beddc3f-4f50-4de9-98bd-a0a3c47d55bb"}}}}, {"uuid": "70456e11-39d7-47ac-b13e-e03e80311b70", "name": "3281dec8-098a-4ae7-be46-083646516e30_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1342890945582846, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10427649324668606, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4afa5e1a-3342-4e5a-83e8-598613d982bc", "name": "55e58dec-bb57-497a-b7ce-60d7f8574200", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "70456e11-39d7-47ac-b13e-e03e80311b70"}}}]}, {"uuid": "bc306be1-27e3-49cd-a6f3-ed5053de4e79", "name": "load_p1rlv20070_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "571a4c92-95b6-4bc0-a25d-0d9239a41a89"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4afa5e1a-3342-4e5a-83e8-598613d982bc"}}}}, {"uuid": "5f5aa3ad-0611-4475-ac97-843774f3e43a", "name": "388bb2a2-2f73-4610-b003-0829cde0cc95_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.025235929487997, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.9672019739719726, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "497e18cb-741a-46d2-93b0-dcb6dfbbb0ee", "name": "3810dbc5-14a3-413a-9555-92bd8326934b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5f5aa3ad-0611-4475-ac97-843774f3e43a"}}}]}, {"uuid": "6fddd001-4af1-4f25-86b8-830cf26fd999", "name": "load_p1rlv20071_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07f95ba5-92dd-465f-a38d-8e878243262b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "497e18cb-741a-46d2-93b0-dcb6dfbbb0ee"}}}}, {"uuid": "badae621-2271-4fbb-92b9-b7997198bc09", "name": "91f81205-3a31-4aeb-9c65-2bdb639fdc05_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.025235929487997, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.9672019739719726, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "686825c9-98a4-4205-ad4f-b655f3770986", "name": "be7d6cf5-80ec-45c1-9e63-37840f8f0eb5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "badae621-2271-4fbb-92b9-b7997198bc09"}}}]}, {"uuid": "09ab72cc-9134-4f4c-9d62-e7368620535e", "name": "load_p1rlv20071_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07f95ba5-92dd-465f-a38d-8e878243262b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "686825c9-98a4-4205-ad4f-b655f3770986"}}}}, {"uuid": "29885444-289e-4567-ac79-716f71b96499", "name": "d6cacb35-de42-4a55-960a-d2fcc20768b0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7653657521185364, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4426471780914222, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "23605292-f6c1-413b-959f-537dfae499e0", "name": "eb57cc4b-8ee1-44ab-a060-0031eb2d1e1a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "29885444-289e-4567-ac79-716f71b96499"}}}]}, {"uuid": "ea97d3d0-d113-42a9-8f4c-98ccd4431741", "name": "load_p1rlv20130_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ffc82be6-f3f8-4a68-b6e6-da60b137329c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "23605292-f6c1-413b-959f-537dfae499e0"}}}}, {"uuid": "628949c4-d977-44b9-83b5-dfc1b83a448b", "name": "a30ce11a-0069-4dc4-9a77-50344fff2ff4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7653657521185364, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4426471780914222, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a61035e4-5d72-4fb3-9918-8fd2bea3a19e", "name": "a97b7f72-290e-4cc7-942a-142650c7bd59", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "628949c4-d977-44b9-83b5-dfc1b83a448b"}}}]}, {"uuid": "814285a8-0508-4c27-b4cd-6e37590517af", "name": "load_p1rlv20130_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ffc82be6-f3f8-4a68-b6e6-da60b137329c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a61035e4-5d72-4fb3-9918-8fd2bea3a19e"}}}}, {"uuid": "37974511-b79e-4aa4-925a-ae52e6643350", "name": "02ac4d7e-f9c1-4888-8e64-96658f31aa7a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1976836424562762, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1051220183522544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "19a3a383-8f39-431d-a32e-0dfac9c66e47", "name": "4716de37-396d-4f84-9047-19015fc4b6f4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "37974511-b79e-4aa4-925a-ae52e6643350"}}}]}, {"uuid": "67877203-07fb-4971-969c-ca1db78cc7c1", "name": "load_p1rlv20138_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d635a151-2d13-47e9-8043-a214415a5b5e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "19a3a383-8f39-431d-a32e-0dfac9c66e47"}}}}, {"uuid": "329f48ca-3283-47e6-9989-c954e7417b71", "name": "f51afa32-de0f-47ab-a4c2-33c692d05346_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1976836424562762, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1051220183522544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "231b0252-b3b4-443d-99cc-1d0e0bb83657", "name": "e5aa4617-1d5e-460f-9043-0d7d915adec8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "329f48ca-3283-47e6-9989-c954e7417b71"}}}]}, {"uuid": "68a7350c-507f-4869-8bad-6bd0a7069723", "name": "load_p1rlv20138_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d635a151-2d13-47e9-8043-a214415a5b5e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "231b0252-b3b4-443d-99cc-1d0e0bb83657"}}}}, {"uuid": "77e49f4b-b3d3-40b3-834f-4c5168226a08", "name": "5fd864fc-b3a0-438c-9346-f231f66958a9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.839175601618853, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4557221316666175, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "78eab5a8-b3fc-48e7-ac43-fd2dd2da903e", "name": "1f056fd1-addf-4713-8e1b-327857a8743d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "77e49f4b-b3d3-40b3-834f-4c5168226a08"}}}]}, {"uuid": "0667c28e-dd8f-4765-b149-bc0a11a22f81", "name": "load_p1rlv20146_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d615e93-a289-41ec-bda0-3b72bf15677e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "78eab5a8-b3fc-48e7-ac43-fd2dd2da903e"}}}}, {"uuid": "506ef5e7-43e3-4523-9e28-9b4722bf0634", "name": "428b8f72-9bcb-4e02-98fc-1659b2b540e2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.839175601618853, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4557221316666175, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c30682c8-b30f-44c9-908c-fc579a66c330", "name": "1fcbb4ac-279f-46a5-868c-3e5365b9bcc8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "506ef5e7-43e3-4523-9e28-9b4722bf0634"}}}]}, {"uuid": "9b0e659d-e509-4ce2-ba46-cca8bfc2a219", "name": "load_p1rlv20146_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d615e93-a289-41ec-bda0-3b72bf15677e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c30682c8-b30f-44c9-908c-fc579a66c330"}}}}, {"uuid": "8e9732f9-6379-4fd0-ac97-9181c8e829d9", "name": "03898ed5-122c-4c49-b780-cd35835216b3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "afd04a47-3d32-4c66-a95c-2d82fcf9cb75", "name": "913241c2-4cb9-4656-aa6f-c928a21d86df", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8e9732f9-6379-4fd0-ac97-9181c8e829d9"}}}]}, {"uuid": "536437b6-5ff9-472d-a83d-fb5675e57c4a", "name": "load_p1rlv20147_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16b2add7-6a6d-4359-ad6f-f60edf435a4c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "afd04a47-3d32-4c66-a95c-2d82fcf9cb75"}}}}, {"uuid": "3731ebe0-ebd8-47e6-9f23-11292962762b", "name": "76137a33-2e13-4efa-aa08-b7f3288379e1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dc3fa00c-5670-4fcc-914d-cb2e2c2380c9", "name": "6048944f-1622-4c7a-9d8b-15c68d67f7dc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3731ebe0-ebd8-47e6-9f23-11292962762b"}}}]}, {"uuid": "598879fc-5988-40ba-b8b1-b7f009c0bd4b", "name": "load_p1rlv20147_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16b2add7-6a6d-4359-ad6f-f60edf435a4c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dc3fa00c-5670-4fcc-914d-cb2e2c2380c9"}}}}, {"uuid": "f10a8db9-e4a7-409d-9fe0-0a9c827524fe", "name": "d2ab8b89-50f4-4fe5-b697-631e8ee4a2bb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7025097104959883, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.553651846257773, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "09f7234d-2f4c-442f-b595-e940779f8e6f", "name": "18d573c6-341a-43af-9f4b-a773e08d4034", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f10a8db9-e4a7-409d-9fe0-0a9c827524fe"}}}]}, {"uuid": "9cd2c69b-6267-4d9c-8085-cee3d6348e34", "name": "load_p1rlv20148_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4a0c2f2-f75e-4c9c-b3f7-d8d9ada9cb82"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "09f7234d-2f4c-442f-b595-e940779f8e6f"}}}}, {"uuid": "662c15fd-8273-4d2a-826c-d63dd0d541a0", "name": "4d2a8b9a-7a08-41c2-9a1f-d7be80a8fc28_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7025097104959883, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.553651846257773, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "13b2ca4a-12c6-4d03-93e8-8035a24731c4", "name": "1accd70c-77fe-4a8b-9f62-a48f71f4108a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "662c15fd-8273-4d2a-826c-d63dd0d541a0"}}}]}, {"uuid": "7dcaeb95-0db1-4839-81dd-b2ffa143a131", "name": "load_p1rlv20148_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4a0c2f2-f75e-4c9c-b3f7-d8d9ada9cb82"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "13b2ca4a-12c6-4d03-93e8-8035a24731c4"}}}}, {"uuid": "3b7d566a-fd60-40c0-888b-37195221ec56", "name": "1eb5f63e-f4c5-47bc-880a-0419ffdc4f60_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.277248598662887, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.143515736159974, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e3821511-30df-465b-acb5-3df5a9431900", "name": "5a7edf86-266b-48de-b000-e3261d2d65ca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3b7d566a-fd60-40c0-888b-37195221ec56"}}}]}, {"uuid": "682c2dbc-2d9f-46b3-a0fc-e78562e8149f", "name": "load_p1rlv20151_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "956f4975-7383-4e0b-9114-d333a6ec4005"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e3821511-30df-465b-acb5-3df5a9431900"}}}}, {"uuid": "6bb11e99-c093-4512-9392-c9dd988042ea", "name": "0acfd7e0-8c71-493f-9322-f74be44fd197_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.277248598662887, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.143515736159974, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3e0146d7-6870-4a6e-a581-9c1c0b4e462b", "name": "5570bc04-89fc-468f-9de1-40cead4ef94f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6bb11e99-c093-4512-9392-c9dd988042ea"}}}]}, {"uuid": "dce30ee9-99e3-4096-a1d2-edfb09ca8731", "name": "load_p1rlv20151_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "956f4975-7383-4e0b-9114-d333a6ec4005"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3e0146d7-6870-4a6e-a581-9c1c0b4e462b"}}}}, {"uuid": "2101c4d2-a7bb-4ec5-a9e0-472a22d2b9ca", "name": "9375f020-eb43-4a91-90bb-7d3471fee0f3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "da803e70-4bd3-4d0f-8a3b-890e59ec93c0", "name": "b8408681-1c10-4ebc-99ce-10c4bb6796e5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2101c4d2-a7bb-4ec5-a9e0-472a22d2b9ca"}}}]}, {"uuid": "e8b7955f-7191-4b62-a82e-079f0f2abdc7", "name": "load_p1rlv20153_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef20846d-d685-4c65-8dfb-bc23317501c5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "da803e70-4bd3-4d0f-8a3b-890e59ec93c0"}}}}, {"uuid": "1322af1c-d5fb-4850-be2e-41cdd0694ee3", "name": "c062e370-2bf3-4980-8f36-b57052d378a5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9353a53d-fd76-4406-82a0-30c0d857bcd0", "name": "f05ecb8f-2027-458d-9583-302b49f3a150", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1322af1c-d5fb-4850-be2e-41cdd0694ee3"}}}]}, {"uuid": "19356f3f-57d5-443b-94c5-61013aa67221", "name": "load_p1rlv20153_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef20846d-d685-4c65-8dfb-bc23317501c5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9353a53d-fd76-4406-82a0-30c0d857bcd0"}}}}, {"uuid": "582666e3-88bd-4406-b4c6-e73bb4b91ba0", "name": "d0e74089-9406-42cb-968c-941ee84e139e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1698158732703443, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8490689598373361, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "53567545-db94-412e-add3-0c889695de31", "name": "8e64aa07-d1a1-4ea2-907b-ace2c89cb4c5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "582666e3-88bd-4406-b4c6-e73bb4b91ba0"}}}]}, {"uuid": "d8613fd8-c758-4c40-98a7-b36993886851", "name": "load_p1rlv20154_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02f2e50e-d42d-47d1-9274-d840042b64d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "53567545-db94-412e-add3-0c889695de31"}}}}, {"uuid": "40f79b36-4145-4613-88ba-89a19ec6e0bf", "name": "f0e82a30-446e-4f1d-9f99-5d6ca2981ced_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1698158732703443, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8490689598373361, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0edebbfd-e6b6-4891-a964-32309e76baf4", "name": "298418b6-5cc5-4ffd-9476-59d005dbfdaa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "40f79b36-4145-4613-88ba-89a19ec6e0bf"}}}]}, {"uuid": "01e845a4-e721-4c3f-8d26-7cb4412b84df", "name": "load_p1rlv20154_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02f2e50e-d42d-47d1-9274-d840042b64d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0edebbfd-e6b6-4891-a964-32309e76baf4"}}}}, {"uuid": "b32c0a9a-d334-4681-857d-fd8ab3a6549d", "name": "cf52475d-8d2b-425a-a6b6-6bd1227771c0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5577393205082823, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5087722503146331, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "01689471-6c73-4ce9-9bac-cb43ee06a20c", "name": "e5d46a68-b1fc-4ec5-86d7-dd92c1328c97", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b32c0a9a-d334-4681-857d-fd8ab3a6549d"}}}]}, {"uuid": "0819d7bb-f90e-43bd-b41a-14b444d08141", "name": "load_p1rlv20160_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27dfea92-734e-49d3-b245-dc933df66889"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "01689471-6c73-4ce9-9bac-cb43ee06a20c"}}}}, {"uuid": "27394fdb-622e-44b6-81d5-1eb9981f00c6", "name": "6e7dcfe2-6b4d-4558-9672-5295b6aa6270_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5577393205082823, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5087722503146331, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "32efff42-1c9a-4a6a-843c-5a318886d726", "name": "4e734bd3-f26b-482b-a8a8-49499875d26a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "27394fdb-622e-44b6-81d5-1eb9981f00c6"}}}]}, {"uuid": "1d5eca10-7bad-482f-80c6-247f8151e31f", "name": "load_p1rlv20160_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27dfea92-734e-49d3-b245-dc933df66889"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "32efff42-1c9a-4a6a-843c-5a318886d726"}}}}, {"uuid": "0755fb9f-6568-4c32-b652-1f92318543fe", "name": "e5463d44-becb-400d-ba47-359a9bf4eed7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.826891988709754, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.5850639012710004, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9906031f-a5da-425e-addb-376808d02468", "name": "b4611dd5-8fd7-4751-bbe7-21bc6d40f9da", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0755fb9f-6568-4c32-b652-1f92318543fe"}}}]}, {"uuid": "f76f88c6-153e-4c33-a478-49634987fdd8", "name": "load_p1rlv20161_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11a125b8-023c-4748-98a9-d74e9e0a7d23"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9906031f-a5da-425e-addb-376808d02468"}}}}, {"uuid": "440780fa-ac19-42bc-b756-9c76d5ee9ca9", "name": "e4e3cfe7-e4c9-4af4-9494-7498213372f2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.826891988709754, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.5850639012710004, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cd182b10-c001-4a5b-9e43-44dc7c455daa", "name": "6753785b-9a38-40d4-ba64-dc7aeda6e217", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "440780fa-ac19-42bc-b756-9c76d5ee9ca9"}}}]}, {"uuid": "befc5031-d584-4387-97d0-6d05dd3b0f94", "name": "load_p1rlv20161_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11a125b8-023c-4748-98a9-d74e9e0a7d23"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cd182b10-c001-4a5b-9e43-44dc7c455daa"}}}}, {"uuid": "2b9916e3-1cc3-40c2-b106-100fbca32bc4", "name": "f482b61d-a170-49f3-adcd-14b9a9aaa2d0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "12c1a588-267c-4df0-92de-712705362eb2", "name": "d546f682-d596-48d1-8a10-beb069f9b663", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2b9916e3-1cc3-40c2-b106-100fbca32bc4"}}}]}, {"uuid": "3186e30a-1daf-47a1-b3a7-7de94b934a1e", "name": "load_p1rlv20163_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e938635b-e0d2-4e1b-a312-5a8f51e1dd7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "12c1a588-267c-4df0-92de-712705362eb2"}}}}, {"uuid": "40513ecc-0631-4feb-bff0-b823f8acbaee", "name": "c21439ba-4ca7-42c0-b8f4-7897a3e295b8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8bb247fa-584b-4826-a3eb-332fb347f14d", "name": "7dbadad6-bb74-4c3f-be9c-5e5f75360e4a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "40513ecc-0631-4feb-bff0-b823f8acbaee"}}}]}, {"uuid": "973dea5e-dd8c-415b-8833-e13c3546485a", "name": "load_p1rlv20163_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e938635b-e0d2-4e1b-a312-5a8f51e1dd7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8bb247fa-584b-4826-a3eb-332fb347f14d"}}}}, {"uuid": "fc046cf8-edf0-4a1f-8754-5be4bb0b4419", "name": "9aa214a9-ac1c-4ac4-be04-d682e3102515_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3462824541838714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7901197550518754, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82ff972c-2cb6-4f7b-bfe3-e8685c86e393", "name": "5a0f9488-66ab-41bf-876b-3a5ad925add7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fc046cf8-edf0-4a1f-8754-5be4bb0b4419"}}}]}, {"uuid": "61c13976-6f8e-4718-8f43-36f89629245a", "name": "load_p1rlv20182_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20f93381-3834-4265-b1ec-5767d171ce0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "82ff972c-2cb6-4f7b-bfe3-e8685c86e393"}}}}, {"uuid": "f5c5ca8e-be6e-4b48-a905-8cd79528f7df", "name": "e7161faf-4531-4d2d-b504-93f71e0fe967_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3462824541838714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7901197550518754, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4eeebcf3-056a-4f59-af07-063d2c3aebeb", "name": "9d0e8107-35e5-4c97-8abe-24118b0ed9d9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f5c5ca8e-be6e-4b48-a905-8cd79528f7df"}}}]}, {"uuid": "812e9359-28ca-4c4c-846e-f1c369d693f9", "name": "load_p1rlv20182_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20f93381-3834-4265-b1ec-5767d171ce0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4eeebcf3-056a-4f59-af07-063d2c3aebeb"}}}}, {"uuid": "a9830c46-efc9-4e6e-9226-0f99af835107", "name": "b61530f2-b813-4330-9c11-d81eedb917b0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8755168938707782, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2009555085079469, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ee98b128-df25-43d4-87c1-f8fe889abcaa", "name": "2142c271-ebf2-4614-8dde-8b98e597f647", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a9830c46-efc9-4e6e-9226-0f99af835107"}}}]}, {"uuid": "88397929-e8cf-468a-ac8a-28e3eb47a3a0", "name": "load_p1rlv20185_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "646058a3-cda7-4723-bd0f-05d305fe7c11"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ee98b128-df25-43d4-87c1-f8fe889abcaa"}}}}, {"uuid": "0d3ad7f6-d3a8-4024-b3c9-bbb592967dab", "name": "0dde55ff-6f5f-4f03-9926-2b0a217728a2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8755168938707782, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2009555085079469, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "277ea683-fcbe-4395-9b33-9052b99b4481", "name": "6177fe72-01fb-4006-b437-863e53d5a251", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0d3ad7f6-d3a8-4024-b3c9-bbb592967dab"}}}]}, {"uuid": "2fe7edb6-18ed-4a59-9a6f-bfb4d2f50581", "name": "load_p1rlv20185_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "646058a3-cda7-4723-bd0f-05d305fe7c11"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "277ea683-fcbe-4395-9b33-9052b99b4481"}}}}, {"uuid": "6e1a9f5a-f7a2-433b-af26-26c9c15d62fe", "name": "8c5d2dcb-b540-4936-9483-c1517b9a0575_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.554325896527151, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5828877012431191, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6d786114-559e-4567-b1a9-491f2ba465f9", "name": "0c229e2e-de38-4ee7-ac97-67c3b5c717cc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6e1a9f5a-f7a2-433b-af26-26c9c15d62fe"}}}]}, {"uuid": "5847e5be-d646-444e-8211-899235c6ef51", "name": "load_p1rlv20188_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abb24254-be79-45d4-8d9b-246b3e89c00f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6d786114-559e-4567-b1a9-491f2ba465f9"}}}}, {"uuid": "3631cd29-11c0-4a70-b9e6-6177be8b554f", "name": "7f4d2eb1-a8d4-4749-ab9e-e92a0cc31f26_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.554325896527151, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5828877012431191, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "115437c8-e691-44ea-9e83-6dc374bc9259", "name": "5b5dfff3-f56a-4af6-b785-50418eaaec42", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3631cd29-11c0-4a70-b9e6-6177be8b554f"}}}]}, {"uuid": "3f45176f-1df3-4292-bc58-2721e0dee7ef", "name": "load_p1rlv20188_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abb24254-be79-45d4-8d9b-246b3e89c00f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "115437c8-e691-44ea-9e83-6dc374bc9259"}}}}, {"uuid": "49562469-1301-4363-95cd-3046593c0adb", "name": "fcd3d06a-e2dc-452a-b50c-2fbaf06ff7b6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0363799452523006, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8773696756055507, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "da655a3b-6207-4105-b2b5-d69624f20812", "name": "6b8dbe70-8270-40b3-a00b-ecd9df03bb39", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "49562469-1301-4363-95cd-3046593c0adb"}}}]}, {"uuid": "7cf357d4-27c1-4541-8cd7-0855ad1b1dc5", "name": "load_p1rlv20277_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb7a8747-a076-469c-a150-35f6763157ec"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "da655a3b-6207-4105-b2b5-d69624f20812"}}}}, {"uuid": "48452f3a-9d18-4066-8409-178fb47c9120", "name": "369c1a0f-a6e3-4469-a1b5-0acd2f52c8e1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0363799452523006, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8773696756055507, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2f45548d-b2ca-4afd-a1d4-558c5eddf0ff", "name": "73e856f3-f8ba-4274-bcc0-4db94de2ad3f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "48452f3a-9d18-4066-8409-178fb47c9120"}}}]}, {"uuid": "a6be9839-5c1b-4d4f-b05c-c986bb22e30b", "name": "load_p1rlv20277_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb7a8747-a076-469c-a150-35f6763157ec"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2f45548d-b2ca-4afd-a1d4-558c5eddf0ff"}}}}, {"uuid": "d41bcd97-b083-4899-8741-6defb5b6dbb0", "name": "23084baa-fb64-4ed3-a74b-f025044ac26b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1813646779377422, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20173832232537287, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9d614edf-f3c2-4712-99e3-094059223132", "name": "e5308187-bb32-4cfb-8b2b-1f60d283de51", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d41bcd97-b083-4899-8741-6defb5b6dbb0"}}}]}, {"uuid": "a1a5093b-f3d8-4fd9-b381-116dec74cf27", "name": "load_p1rlv20281_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f23405b-432f-45ff-a7b1-0b7147cddfc8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9d614edf-f3c2-4712-99e3-094059223132"}}}}, {"uuid": "71c2e802-a315-4089-9729-f73dd906daee", "name": "b4f5e80a-6212-47ed-9404-91a51057ecd2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1813646779377422, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20173832232537287, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b9ba64f9-1cbc-4a5d-be48-20111b1287ef", "name": "8acbf98f-0273-431c-abf0-20ea79a0bc28", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "71c2e802-a315-4089-9729-f73dd906daee"}}}]}, {"uuid": "1755aad6-21f9-4bb5-b0d6-a7ae5e6b3ad5", "name": "load_p1rlv20281_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f23405b-432f-45ff-a7b1-0b7147cddfc8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b9ba64f9-1cbc-4a5d-be48-20111b1287ef"}}}}, {"uuid": "689f32c9-d186-48b3-a8ec-429949952c0f", "name": "01463a59-3f92-4fbd-baed-8cf8b363221e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2766983969851713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5028612878254624, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3f980f97-c5a3-4719-8006-0b9d4aa8b5a3", "name": "3ba769f6-84c3-4d18-b2a7-f90181ad0bc0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "689f32c9-d186-48b3-a8ec-429949952c0f"}}}]}, {"uuid": "e1d8f0c8-3c29-4b77-acc9-9b57270a4d1a", "name": "load_p1rlv20284_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25837ab0-0fb8-4346-94ad-561ff9ff7f0c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3f980f97-c5a3-4719-8006-0b9d4aa8b5a3"}}}}, {"uuid": "97a52d88-a34a-4ad5-b103-602e9e4264e9", "name": "0200df23-bb54-4357-b643-2d48e26695e3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2766983969851713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5028612878254624, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7902ab99-1ca8-45de-a413-dd2372e8f08c", "name": "42525e2f-3479-401f-b10c-276c5855ea32", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "97a52d88-a34a-4ad5-b103-602e9e4264e9"}}}]}, {"uuid": "5c7ebc0b-5d52-45c2-9464-3daa5289b5de", "name": "load_p1rlv20284_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25837ab0-0fb8-4346-94ad-561ff9ff7f0c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7902ab99-1ca8-45de-a413-dd2372e8f08c"}}}}, {"uuid": "d3ea8fe8-e245-4310-bdcd-c00b9ae6a0a0", "name": "d3bf749d-369b-4f9a-a81f-d7cdd696a223_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.883515343353138, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18989418857380705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c49e716e-4a88-4679-aae4-91b2e7bfd7af", "name": "a8a5d2be-83a1-4e95-8713-add634e266c8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d3ea8fe8-e245-4310-bdcd-c00b9ae6a0a0"}}}]}, {"uuid": "73cd87f9-90e9-426c-8cdb-dd9fae4321f5", "name": "load_p1rlv20296_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a8ae6dc-884d-48d8-9995-fe3936ad019c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c49e716e-4a88-4679-aae4-91b2e7bfd7af"}}}}, {"uuid": "e9a77572-7cc3-44e3-aa73-162851150d07", "name": "ed77ba44-c96a-4c66-b55e-6ad9b009db3e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.883515343353138, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18989418857380705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6e3749ca-15f3-4e70-ba98-cb72a5d62b4d", "name": "23aebaf6-1ac9-49fc-8bff-f7387b987557", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e9a77572-7cc3-44e3-aa73-162851150d07"}}}]}, {"uuid": "209538f5-f332-4d02-adf0-a57fe9255933", "name": "load_p1rlv20296_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a8ae6dc-884d-48d8-9995-fe3936ad019c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6e3749ca-15f3-4e70-ba98-cb72a5d62b4d"}}}}, {"uuid": "674e61df-acfa-4ba9-a25c-a0ef9c3d7234", "name": "52a05c32-4595-4e35-8b75-9dfc10adb02f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.882765489125589, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7706550587664386, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3d96ba4a-9748-4117-9115-0ec6e4a84d97", "name": "f149b8f3-ffe6-4eb8-9c70-3037d949c8ce", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "674e61df-acfa-4ba9-a25c-a0ef9c3d7234"}}}]}, {"uuid": "e583e114-43fa-4279-8479-0a9b6f760cd8", "name": "load_p1rlv20300_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da62d78e-e221-423a-8da0-8d36ce1f7508"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3d96ba4a-9748-4117-9115-0ec6e4a84d97"}}}}, {"uuid": "231f7ff9-e2a6-422f-868e-484d14a19fb3", "name": "61ae5d4b-8e33-4476-9faf-c4e177b90cfc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.882765489125589, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7706550587664386, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "814c2e34-5564-4e3c-b825-299f449c1549", "name": "6647d065-688f-4a0c-be0e-57e96810df79", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "231f7ff9-e2a6-422f-868e-484d14a19fb3"}}}]}, {"uuid": "8167385d-15e1-43ed-87a9-157820a44468", "name": "load_p1rlv20300_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da62d78e-e221-423a-8da0-8d36ce1f7508"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "814c2e34-5564-4e3c-b825-299f449c1549"}}}}, {"uuid": "a69441e7-20bf-4633-9680-549d96bc42b5", "name": "e26b65fb-b834-4d3d-abd7-e0398420cb28_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.693241087582845, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5112522017919784, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10eadc14-2c10-4e7e-9c68-5db44d506d7d", "name": "9dacf371-4b31-4a2a-a482-d985e56df868", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a69441e7-20bf-4633-9680-549d96bc42b5"}}}]}, {"uuid": "c60d84a8-585f-4b23-9e8f-683aaaf84f41", "name": "load_p1rlv20309_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e5718ad-0b70-4ea4-b2f2-31f0ea5c5d5b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10eadc14-2c10-4e7e-9c68-5db44d506d7d"}}}}, {"uuid": "3845555f-4b62-4dfc-b4b7-37d8efd82575", "name": "604a9fac-d7a2-44b0-8c14-02e979a21980_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.693241087582845, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5112522017919784, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3061bc64-6954-4cb0-af8c-42bea15eb1ff", "name": "8711a927-6ff3-4819-b6d6-1e02c035eaeb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3845555f-4b62-4dfc-b4b7-37d8efd82575"}}}]}, {"uuid": "d2319eca-b2e2-493f-bbc5-9c465e6d19f1", "name": "load_p1rlv20309_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e5718ad-0b70-4ea4-b2f2-31f0ea5c5d5b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3061bc64-6954-4cb0-af8c-42bea15eb1ff"}}}}, {"uuid": "ab26b536-8e98-4cbd-826e-632038c7aa68", "name": "43a3ddac-87b5-4f7d-a777-e36b7cd087a7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.771789007275423, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6748983225226206, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "94e5a2f6-c580-487f-b991-e648af18c2b3", "name": "789e3f04-ec58-4372-a305-0e7d67f232dd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ab26b536-8e98-4cbd-826e-632038c7aa68"}}}]}, {"uuid": "67d5a93f-9cc6-4996-875a-ead4a2259149", "name": "load_p1rlv20333_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c23afdc0-ab93-4d43-8eec-613eab21cd74"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "94e5a2f6-c580-487f-b991-e648af18c2b3"}}}}, {"uuid": "1f0b1832-82ee-4ba8-8223-466b960951ce", "name": "846779ae-8e22-4d09-81e5-17492a80c258_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.771789007275423, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6748983225226206, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ef8fd0ff-288b-430f-b0cf-cda84570432d", "name": "739f4418-858f-4ed2-9995-c7d33f959819", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1f0b1832-82ee-4ba8-8223-466b960951ce"}}}]}, {"uuid": "63ab5d3b-31a1-40da-b0d8-5e02c8252274", "name": "load_p1rlv20333_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c23afdc0-ab93-4d43-8eec-613eab21cd74"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ef8fd0ff-288b-430f-b0cf-cda84570432d"}}}}, {"uuid": "2c59ab6a-27f7-4bf4-b196-491740e3eea2", "name": "1bf779d5-b9fb-4c49-a1ec-8c5e9c95ad86_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4663769608466568, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5502546109327153, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f0b41a56-9e28-4e39-853a-5fd6b3a3f759", "name": "35f13eff-e9a2-464e-9b8c-a394a22fba9c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2c59ab6a-27f7-4bf4-b196-491740e3eea2"}}}]}, {"uuid": "947a6e02-28d8-48d0-a08b-2755c2ef0a5a", "name": "load_p1rlv20358_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b5d2dfa-895b-4afc-a7fe-449960adba41"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f0b41a56-9e28-4e39-853a-5fd6b3a3f759"}}}}, {"uuid": "f2d0f53c-e96d-4415-9be7-7c18d2921e78", "name": "1d8dc242-b4c0-4991-a303-dd2696fd8062_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4663769608466568, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5502546109327153, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "add10e60-b423-40da-9574-89fe3fd70430", "name": "dab80639-1aba-48f6-82a0-59a1e3a61146", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f2d0f53c-e96d-4415-9be7-7c18d2921e78"}}}]}, {"uuid": "1ff5e68d-e4ac-4cbf-ab60-fa72da086e84", "name": "load_p1rlv20358_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b5d2dfa-895b-4afc-a7fe-449960adba41"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "add10e60-b423-40da-9574-89fe3fd70430"}}}}, {"uuid": "b721e110-586f-4991-b001-e8231b9a661a", "name": "4f4600d5-3b68-43ae-9fc4-682eb9a82ec5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.234980013002153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7303750309107965, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "84307684-e352-4ed0-8167-f34fd87e6a0e", "name": "a37056e5-15cf-46ee-a399-2919d04cef17", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b721e110-586f-4991-b001-e8231b9a661a"}}}]}, {"uuid": "24a685f1-f697-42a7-8baf-26bd8d3a777c", "name": "load_p1rlv20432_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4b5327a-85a3-496c-859c-f887a38513cd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "84307684-e352-4ed0-8167-f34fd87e6a0e"}}}}, {"uuid": "cfe04cf1-1d36-49b4-8437-1c3cfb4ad9ac", "name": "fe88a424-87cc-4d87-8469-62f10e845aae_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.234980013002153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7303750309107965, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dad3dd9c-6e71-48c0-bfcf-864ab6075d33", "name": "5b53255a-f320-42bd-b033-28f0ee0d898d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cfe04cf1-1d36-49b4-8437-1c3cfb4ad9ac"}}}]}, {"uuid": "b338d19c-0240-4a2f-a921-41e0f09d9388", "name": "load_p1rlv20432_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4b5327a-85a3-496c-859c-f887a38513cd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dad3dd9c-6e71-48c0-bfcf-864ab6075d33"}}}}, {"uuid": "2f56313c-3d79-46a7-a0ca-9d045bd29bea", "name": "582f7ddf-5577-4b76-a74c-572604dea4bc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.875485744114147, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.294896241985991, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1702993d-c1f9-4973-b193-3a8585e423a0", "name": "c096483d-27aa-424a-ab54-603c3cb0b381", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2f56313c-3d79-46a7-a0ca-9d045bd29bea"}}}]}, {"uuid": "883a1c8e-13a5-43b7-8fcf-15e3d109de8d", "name": "load_p1rlv20450_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "006c2753-37b3-4b59-82a6-8ce95f316e26"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1702993d-c1f9-4973-b193-3a8585e423a0"}}}}, {"uuid": "ce653358-2d5e-4f72-b43b-295514bc1cad", "name": "cc6468ed-786c-4572-82a8-5d6b57b04a3b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.875485744114147, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.294896241985991, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "18b9c629-85b9-42dc-ab5d-6d5c3b3071cc", "name": "82ea8c9f-863a-4388-a0ae-d3d2203bccbc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ce653358-2d5e-4f72-b43b-295514bc1cad"}}}]}, {"uuid": "b534e7d7-118c-4848-95ae-fcc2f4ed6e5f", "name": "load_p1rlv20450_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "006c2753-37b3-4b59-82a6-8ce95f316e26"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "18b9c629-85b9-42dc-ab5d-6d5c3b3071cc"}}}}, {"uuid": "5b9b6951-75e2-4637-a256-d849e3b06acf", "name": "656a36cf-f25b-4120-8099-158fe0f59230_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b8a0bdaa-7756-4107-b440-71e5df460e62", "name": "18d974a3-94a5-4caa-bd9f-2a1e5338cd51", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b9b6951-75e2-4637-a256-d849e3b06acf"}}}]}, {"uuid": "dd86f627-1fdb-4186-8fd2-5a821ad6b167", "name": "load_p1rlv20451_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c37708d8-1e83-4e76-ac7f-0d29ba6b7c4e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b8a0bdaa-7756-4107-b440-71e5df460e62"}}}}, {"uuid": "2c4105ad-2941-4a5e-8da0-084fe4c47413", "name": "358342e3-0ff1-4fbe-bfe9-b931af7cada5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "11e14820-7282-4d71-a652-1df122e93ae3", "name": "ed38027a-bde9-4103-bada-f0cbe9f21e63", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2c4105ad-2941-4a5e-8da0-084fe4c47413"}}}]}, {"uuid": "d0489582-81ad-47e8-ac14-e3d9782482a9", "name": "load_p1rlv20451_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c37708d8-1e83-4e76-ac7f-0d29ba6b7c4e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "11e14820-7282-4d71-a652-1df122e93ae3"}}}}, {"uuid": "04a63073-b106-4c96-af0d-750e7142c296", "name": "3789b483-2c9e-4cdc-850b-1f6a72bcef77_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.250267265771566, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8009319586825154, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f16238df-3368-4a62-8c92-7c5c72897070", "name": "fa0828f4-8786-4eab-b890-f711c0f4100e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "04a63073-b106-4c96-af0d-750e7142c296"}}}]}, {"uuid": "81cb1766-7c52-4734-b2c2-41c66ce8a702", "name": "load_p1rlv20453_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4e21b79-d2be-4a53-be46-32331e61f89c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f16238df-3368-4a62-8c92-7c5c72897070"}}}}, {"uuid": "d5049aa4-9273-407c-94cf-05ca8a440bb5", "name": "9aed6232-19be-49ed-8f87-15b4a5c57259_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.250267265771566, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8009319586825154, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82923a7e-5484-4585-9ca1-a210dbd4353c", "name": "f8f24d31-bdc4-422b-bb31-6ea4a915fff6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d5049aa4-9273-407c-94cf-05ca8a440bb5"}}}]}, {"uuid": "3130ec59-302e-4764-b6ec-7a2c174c82fc", "name": "load_p1rlv20453_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4e21b79-d2be-4a53-be46-32331e61f89c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "82923a7e-5484-4585-9ca1-a210dbd4353c"}}}}, {"uuid": "5fed4409-884d-4852-aaca-6254e421f131", "name": "48f05232-d2cd-4c7f-b426-e33a74da8e37_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8249779386922644, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12555321354723425, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5cf1d9db-65c5-40e1-a2ad-8266c84ccbeb", "name": "45f27dfc-ed96-4912-abc5-76bb39a907a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5fed4409-884d-4852-aaca-6254e421f131"}}}]}, {"uuid": "d759ae69-49ba-4eae-9068-7d6580520328", "name": "load_p1rlv20455_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8934db59-0c39-4838-9f8c-59a563cd9d54"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5cf1d9db-65c5-40e1-a2ad-8266c84ccbeb"}}}}, {"uuid": "229b6a23-244e-4532-9a35-bca51bcf0c42", "name": "59d624f6-8c91-48de-bad6-4f0278258187_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8249779386922644, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12555321354723425, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cef84716-de5d-4d70-ac0d-8789997937fd", "name": "f1b9614f-d493-439e-8adb-16d290302ab6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "229b6a23-244e-4532-9a35-bca51bcf0c42"}}}]}, {"uuid": "dcfeb706-43bf-4843-a816-558d7581b181", "name": "load_p1rlv20455_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8934db59-0c39-4838-9f8c-59a563cd9d54"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cef84716-de5d-4d70-ac0d-8789997937fd"}}}}, {"uuid": "6d1cbd3e-0a5d-405e-b2a1-5a12b82418ab", "name": "7d23ff30-ed71-4481-9b7e-5f6e41217722_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8374792851175116, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3203908676737591, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "84f5cd6e-2311-496e-b43d-4ca722b1bd78", "name": "663baad0-b0d9-45a7-927e-a0e5745d093d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6d1cbd3e-0a5d-405e-b2a1-5a12b82418ab"}}}]}, {"uuid": "15618555-50c1-4539-9f13-79af73f29385", "name": "load_p1rlv20456_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7a43aa6-2be8-4320-8089-57d388633c6b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "84f5cd6e-2311-496e-b43d-4ca722b1bd78"}}}}, {"uuid": "3d0161c8-eb1c-4ee5-9650-143e945be3cf", "name": "0532cf22-4356-42b2-9e53-0041df647378_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8374792851175116, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3203908676737591, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e1f2743d-7186-44c8-8f9a-eaa189699efd", "name": "92bd0fa1-7f76-4bc0-9d50-9025b4331053", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3d0161c8-eb1c-4ee5-9650-143e945be3cf"}}}]}, {"uuid": "287913e4-5259-480f-8263-e9c579b303b3", "name": "load_p1rlv20456_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7a43aa6-2be8-4320-8089-57d388633c6b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e1f2743d-7186-44c8-8f9a-eaa189699efd"}}}}, {"uuid": "34dc3d17-22d5-4269-b173-57f37f258b5d", "name": "a7178ff2-912b-40c4-83e7-d36982eb2cf3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "daccca9a-4139-4678-8213-c2c1a0d5452b", "name": "c42dc409-047a-4727-b120-e73d258a5d04", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "34dc3d17-22d5-4269-b173-57f37f258b5d"}}}]}, {"uuid": "0427d862-2997-45d5-8577-931c32fbd39d", "name": "load_p1rlv20459_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dfcfdbf-0051-4eef-bea6-97446cee21e4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "daccca9a-4139-4678-8213-c2c1a0d5452b"}}}}, {"uuid": "945cb6b6-8779-42d6-9cb7-b12d175781b1", "name": "bdf587e2-5289-4da2-966b-c4c582a9b1eb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ef5f0664-db91-4bdd-8bb9-3db366347fb4", "name": "6b3f9973-e997-4894-b53c-4f7487109a22", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "945cb6b6-8779-42d6-9cb7-b12d175781b1"}}}]}, {"uuid": "4fa9fb29-e1fd-4f0c-9408-5b718718758e", "name": "load_p1rlv20459_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dfcfdbf-0051-4eef-bea6-97446cee21e4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ef5f0664-db91-4bdd-8bb9-3db366347fb4"}}}}, {"uuid": "401ed287-96c4-47ad-bb6b-c09376d9100b", "name": "fbb8c89b-8c5f-4ce4-ac79-225a79a3328c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8140781365796688, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5845737413475921, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "41ccd785-e72f-49fe-8791-f254aa1574ef", "name": "1b19f048-ac7a-4b40-bfe7-bc60a1426077", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "401ed287-96c4-47ad-bb6b-c09376d9100b"}}}]}, {"uuid": "8793d403-b23e-48cc-9bd9-4c73108709e0", "name": "load_p1rlv20465_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4759390d-43ec-45c9-9cca-320020dc1150"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "41ccd785-e72f-49fe-8791-f254aa1574ef"}}}}, {"uuid": "7fe82b55-5c16-40c9-b10e-5bc64c7fc02d", "name": "b5e45d5d-1bf7-4a54-a0d0-98e9e7e76ef7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8140781365796688, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5845737413475921, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f8024279-8d0b-4396-80aa-b0ebebd0bb90", "name": "18145921-4d73-4934-baed-7944f959f685", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7fe82b55-5c16-40c9-b10e-5bc64c7fc02d"}}}]}, {"uuid": "1ccceec8-8328-4dad-825d-786eb05ffcf0", "name": "load_p1rlv20465_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4759390d-43ec-45c9-9cca-320020dc1150"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f8024279-8d0b-4396-80aa-b0ebebd0bb90"}}}}, {"uuid": "ec91887c-9c4e-45fb-9283-1d9509dc8801", "name": "69b9e34b-1f8a-4670-bfba-5681e8c2ea10_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "565c66a1-9d75-4eb6-9103-dd216b5b89de", "name": "0d7f9147-a203-4140-96f3-5d6a51114635", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ec91887c-9c4e-45fb-9283-1d9509dc8801"}}}]}, {"uuid": "0d76342c-2396-4214-a4bf-f456d4521254", "name": "load_p1rlv20467_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58e2b774-ac04-435e-9e03-573b3aa94cfb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "565c66a1-9d75-4eb6-9103-dd216b5b89de"}}}}, {"uuid": "329fcd7f-6421-421b-a1e9-a0c9774a3398", "name": "c992e272-c468-4173-b205-553f230c7f23_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "83d890be-1de3-4c73-b7f3-4533594fb921", "name": "963b00b2-8d48-461e-aa6b-f857cca4ce80", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "329fcd7f-6421-421b-a1e9-a0c9774a3398"}}}]}, {"uuid": "8018e55d-e577-4e29-81d2-c6b758885388", "name": "load_p1rlv20467_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58e2b774-ac04-435e-9e03-573b3aa94cfb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "83d890be-1de3-4c73-b7f3-4533594fb921"}}}}, {"uuid": "7a1018dc-731c-4c84-8596-ccae7cce63bf", "name": "a66deca1-7605-4fe6-af3e-a2b629aaaf29_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9559171691321495, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6431a71d-fb58-4b2b-8728-b2f14b275221", "name": "99a19f84-1a9f-4e1c-8ba7-d9c94a2d0e14", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7a1018dc-731c-4c84-8596-ccae7cce63bf"}}}]}, {"uuid": "3d34d545-10cb-4ec2-844c-f8aa84b45fdb", "name": "load_p1rlv20469_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60fe0a16-aa4d-4fe8-9f39-81bfa13b505f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6431a71d-fb58-4b2b-8728-b2f14b275221"}}}}, {"uuid": "fc3a51b6-688a-4fe9-8c0f-4da7edd2e08e", "name": "ad5093ab-3779-47c2-834b-3b4c0e4ff47c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9559171691321495, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f374207e-cb43-4462-a20a-bc0597568d97", "name": "62de9be0-ce10-4551-ae7a-ecfc395afad7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fc3a51b6-688a-4fe9-8c0f-4da7edd2e08e"}}}]}, {"uuid": "7a2fe99a-ab27-4605-a90e-794c1864d276", "name": "load_p1rlv20469_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60fe0a16-aa4d-4fe8-9f39-81bfa13b505f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f374207e-cb43-4462-a20a-bc0597568d97"}}}}, {"uuid": "9652105b-26c8-43e1-86c9-fa3508510c4b", "name": "695f24d1-bcff-4c46-96de-e6e71d9e5aaf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.772705532239135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.33568286747913667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5091744d-12e4-4e1b-8838-937c50b63054", "name": "8675ddbe-5371-4ce2-a56e-5ec053964822", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9652105b-26c8-43e1-86c9-fa3508510c4b"}}}]}, {"uuid": "9745b2e8-cce1-42d7-bcb4-17d99d414e3e", "name": "load_p1rlv20473_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3eb214b9-827f-4995-a862-907be02b029d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5091744d-12e4-4e1b-8838-937c50b63054"}}}}, {"uuid": "be39e594-4f05-4bee-9b74-0fac136bb8ec", "name": "bc764a14-2cde-40d3-b6d5-84493c3f6efd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.772705532239135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.33568286747913667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d0a874a8-6ba0-4050-a7cc-c432c61f2415", "name": "15c7b000-6321-4bef-bfa7-4977989eaf80", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "be39e594-4f05-4bee-9b74-0fac136bb8ec"}}}]}, {"uuid": "52a31c24-3b82-4447-8912-06dbd691546d", "name": "load_p1rlv20473_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3eb214b9-827f-4995-a862-907be02b029d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d0a874a8-6ba0-4050-a7cc-c432c61f2415"}}}}, {"uuid": "1d21b064-5365-4048-872a-21abd9d21293", "name": "203c3bda-70e3-493b-b693-f5588be13c2f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "735cda5d-5016-48cd-aaa0-463cd519da98", "name": "157da864-e8b2-4903-b5ed-8c0fe72c4782", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1d21b064-5365-4048-872a-21abd9d21293"}}}]}, {"uuid": "80f467e5-7f90-44a6-8356-7cf7914e5f6d", "name": "load_p1rlv20478_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cd0effe0-d186-41a8-8197-24144fbc6218"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "735cda5d-5016-48cd-aaa0-463cd519da98"}}}}, {"uuid": "7709f9bd-c129-48d8-b9a6-eb8ed8f0e5f1", "name": "068ba0fc-60a4-41bf-bd57-90aea5217b06_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.587045329539647, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3923216471043, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5fb3ed72-dd15-40c3-9fe4-84422b9d980e", "name": "dc761561-95d5-4345-a360-e22a514fd231", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7709f9bd-c129-48d8-b9a6-eb8ed8f0e5f1"}}}]}, {"uuid": "6c849935-fc6e-4c1e-9641-f6249caab38e", "name": "load_p1rlv20478_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cd0effe0-d186-41a8-8197-24144fbc6218"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5fb3ed72-dd15-40c3-9fe4-84422b9d980e"}}}}, {"uuid": "fd483ed2-68e3-445f-b375-06f936328d53", "name": "3d0dde73-4edb-4ff9-81ec-866af2313355_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4437884187508536, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6647073432497462, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "564d4ca5-373b-4f67-b677-422237e5ea0c", "name": "81315c28-c714-483b-af7d-e470c300d902", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fd483ed2-68e3-445f-b375-06f936328d53"}}}]}, {"uuid": "eade93de-ff75-4263-ab36-37f6392c70f8", "name": "load_p1rlv20480_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5d0a174-d49d-4c7e-a669-092f6408edf4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "564d4ca5-373b-4f67-b677-422237e5ea0c"}}}}, {"uuid": "1ce17efe-78d1-4851-ac9e-8ade9592e23b", "name": "bcf26ca4-bb62-446c-ba60-137cc3419286_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4437884187508536, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6647073432497462, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5d58b329-940f-499f-99e1-f5e6ebdd66d0", "name": "c2488af4-3aee-404f-9a2b-844cc1c7ef27", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1ce17efe-78d1-4851-ac9e-8ade9592e23b"}}}]}, {"uuid": "d89233ce-3b5c-40c2-8148-39cb020e8556", "name": "load_p1rlv20480_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5d0a174-d49d-4c7e-a669-092f6408edf4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5d58b329-940f-499f-99e1-f5e6ebdd66d0"}}}}, {"uuid": "39cdc73d-09f9-44e8-822c-9c513c93ff9e", "name": "565e2c77-bd5f-48f1-a5b6-232fd14fd774_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.109177669729331, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5486693289215298, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "66863d2d-5d48-44a0-996e-27f9e773740f", "name": "0cd7736a-ed87-4516-b385-4b23997e7ddd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "39cdc73d-09f9-44e8-822c-9c513c93ff9e"}}}]}, {"uuid": "3be81848-c16d-4e15-8043-56eab74dec44", "name": "load_p1rlv20492_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7af262b7-285c-4d06-b7ff-2f2a1971055a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "66863d2d-5d48-44a0-996e-27f9e773740f"}}}}, {"uuid": "3f800f84-d5ef-474a-be18-715755ebc8ca", "name": "cad3c948-664a-4ddd-a2ae-731cf726bb28_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.109177669729331, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5486693289215298, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f657e04d-89e2-439a-b2c5-dcdcbc637963", "name": "3c70cbae-4ecd-4f93-a71d-6ae728057831", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3f800f84-d5ef-474a-be18-715755ebc8ca"}}}]}, {"uuid": "cc77e7e8-e03c-4713-b2fa-215d3f2c2243", "name": "load_p1rlv20492_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7af262b7-285c-4d06-b7ff-2f2a1971055a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f657e04d-89e2-439a-b2c5-dcdcbc637963"}}}}, {"uuid": "39a51d11-5f0c-46c0-b4c7-2af2dd954ebc", "name": "81a41b58-eb9a-4539-a878-7dba2c28b143_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9444657359992037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.058006608995704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "37b07b41-077a-45c0-9324-13d6a7ba74d4", "name": "de4576f0-f6f8-4e80-8ef6-1773aa55e02e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "39a51d11-5f0c-46c0-b4c7-2af2dd954ebc"}}}]}, {"uuid": "2909b0c0-845f-4562-af72-2f9305e7abba", "name": "load_p1rlv20499_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af153ed-ed39-4433-ac12-19dfdb7b6bef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "37b07b41-077a-45c0-9324-13d6a7ba74d4"}}}}, {"uuid": "fb25be19-608e-41ef-9a56-cfd291dce449", "name": "a6005aed-4468-4377-9284-35ef79ff1428_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9444657359992037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.058006608995704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5ad5caa6-9a08-49c6-904c-a1a531c6ef73", "name": "2e525d33-9f5a-4a97-b599-023512e9421b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fb25be19-608e-41ef-9a56-cfd291dce449"}}}]}, {"uuid": "4a126325-c6b8-473a-a8f8-57f06397f106", "name": "load_p1rlv20499_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af153ed-ed39-4433-ac12-19dfdb7b6bef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5ad5caa6-9a08-49c6-904c-a1a531c6ef73"}}}}, {"uuid": "6d3471e3-3363-42fc-9259-5602fc27ed6c", "name": "1b7f7368-03e3-49c2-aca1-32a570bc7c83_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7956093485713416, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7629429667228578, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "373e538b-b9e4-4ca6-a1f2-6f2097d56b4b", "name": "b4accc81-346a-4c78-adb5-a3e46f18d6ca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6d3471e3-3363-42fc-9259-5602fc27ed6c"}}}]}, {"uuid": "46bb7b31-1c51-4577-a18f-e029061f6d23", "name": "load_p1rlv20502_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cacd3e49-55aa-4f05-bd7d-ae8aba0af87f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "373e538b-b9e4-4ca6-a1f2-6f2097d56b4b"}}}}, {"uuid": "8288e370-9098-494a-965c-85088e722ff3", "name": "05b0d269-5681-4ae5-888d-3811295a6736_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7956093485713416, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7629429667228578, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "141d6878-08dd-4335-838c-ad91b1d41622", "name": "a2055bd1-9ce8-4515-a48e-55eec6b1e260", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8288e370-9098-494a-965c-85088e722ff3"}}}]}, {"uuid": "d8f4b17f-af30-4202-a34d-50a18a3b0803", "name": "load_p1rlv20502_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cacd3e49-55aa-4f05-bd7d-ae8aba0af87f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "141d6878-08dd-4335-838c-ad91b1d41622"}}}}, {"uuid": "3359d395-ff77-4ea4-9c0c-99736773de9c", "name": "32c12bb3-5eca-41a1-99de-3f8946788258_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1419f1bb-43f7-42df-90f7-d852fab4f04f", "name": "a1ab948c-b0c8-467b-8e1d-009a593a9d49", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3359d395-ff77-4ea4-9c0c-99736773de9c"}}}]}, {"uuid": "f5b597dd-6be9-4387-86cd-b9353cfb2945", "name": "load_p1rlv20504_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b3e7495-7732-42ce-8d53-a5f1b7383ce4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1419f1bb-43f7-42df-90f7-d852fab4f04f"}}}}, {"uuid": "1b9c8237-cdcc-4788-8dc9-a2e38cae3cfd", "name": "9fc3d9d1-be67-42d0-b13b-fbe934a1f866_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3943082875115844, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23580666776835482, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10916cfb-46ea-418a-9fe5-97fc48b4b6ef", "name": "0f24b9ae-8dad-43d2-9345-f895af4434c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1b9c8237-cdcc-4788-8dc9-a2e38cae3cfd"}}}]}, {"uuid": "d4de4534-9b56-46f9-80ab-765f25e29ca7", "name": "load_p1rlv20504_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b3e7495-7732-42ce-8d53-a5f1b7383ce4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10916cfb-46ea-418a-9fe5-97fc48b4b6ef"}}}}, {"uuid": "c9eb1619-3c3d-4f08-8a82-c8c2946520b8", "name": "cbf50237-7e76-43f1-a222-375cca9e6ed2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4699462180170992, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3815978523472859, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9432afde-7c88-4d3e-868e-97f3205456a3", "name": "6d2fbc95-5243-4480-99fe-ceee1232380c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9eb1619-3c3d-4f08-8a82-c8c2946520b8"}}}]}, {"uuid": "b276dd5f-841c-4c7a-aa73-fbd5e223bf2f", "name": "load_p1rlv20509_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fe37b51-0258-4812-9d96-3cc28c4bd55b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9432afde-7c88-4d3e-868e-97f3205456a3"}}}}, {"uuid": "c8c20fa6-a023-4e8d-a933-7d2719c5465a", "name": "42b7aab2-d56b-4355-88df-e601c8f31bdb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4699462180170992, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3815978523472859, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e7ded97f-bbc4-4b6f-ae64-81781795ede1", "name": "c378b47a-4b56-42f7-8cc0-a1aeeffc51c8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c8c20fa6-a023-4e8d-a933-7d2719c5465a"}}}]}, {"uuid": "f4dfab8b-a25e-41f8-a9f4-e82697795162", "name": "load_p1rlv20509_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fe37b51-0258-4812-9d96-3cc28c4bd55b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e7ded97f-bbc4-4b6f-ae64-81781795ede1"}}}}, {"uuid": "9bf4e191-bba9-4688-86c3-11e2a3b1556c", "name": "486fa29e-1442-4521-b654-5df94e5acf1b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.996798907530164, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8717719006522443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "22e04164-803c-48f5-a56d-12cf40f867a1", "name": "d9db1151-69f7-4de1-9369-643383b87847", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9bf4e191-bba9-4688-86c3-11e2a3b1556c"}}}]}, {"uuid": "d09f7d54-3513-4a3b-bf4f-7fda658684de", "name": "load_p1rlv38126_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa4eed95-33b7-4827-8744-52d14149b386"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "22e04164-803c-48f5-a56d-12cf40f867a1"}}}}, {"uuid": "6736f48a-4c11-43b4-891f-9f29b71f0493", "name": "cd2cfbb2-88c7-4456-88bb-e68221dbd5bf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.996798907530164, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8717719006522443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ca6624d5-7866-48be-9078-6446a8a1c9d2", "name": "9a1029dd-92d1-4ec6-b1c5-2b26f4e507e6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6736f48a-4c11-43b4-891f-9f29b71f0493"}}}]}, {"uuid": "948ee14d-09ae-452c-9a1a-fe2b0b24d3d2", "name": "load_p1rlv38126_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa4eed95-33b7-4827-8744-52d14149b386"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ca6624d5-7866-48be-9078-6446a8a1c9d2"}}}}, {"uuid": "5a62a170-8408-4aee-ac89-b87283b59ca9", "name": "492571f6-4b8e-4149-8af4-782cf955b9e6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.771789007275423, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6748983225226206, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2bc2e514-fab8-4c9f-b7b8-411b8efda667", "name": "9501e8c1-8685-4967-a88e-abf0af5efe9d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5a62a170-8408-4aee-ac89-b87283b59ca9"}}}]}, {"uuid": "397cd87a-7d75-4f45-aa6f-52fe2df03ef8", "name": "load_p1rlv38269_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cbb9976-253c-4863-899f-9218c4496688"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2bc2e514-fab8-4c9f-b7b8-411b8efda667"}}}}, {"uuid": "5214f41f-f6cf-482d-a6ea-e38a09940a99", "name": "0a35ab40-62f0-409a-b114-8c09acffbd43_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.771789007275423, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6748983225226206, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5352644d-0db9-4d77-a7a8-6e0a66ca84b7", "name": "c2b502d9-0a08-4b93-9f2c-0c0ce6dd602b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5214f41f-f6cf-482d-a6ea-e38a09940a99"}}}]}, {"uuid": "fa091356-cbf4-4839-924a-1f6693e3ebbf", "name": "load_p1rlv38269_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cbb9976-253c-4863-899f-9218c4496688"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5352644d-0db9-4d77-a7a8-6e0a66ca84b7"}}}}, {"uuid": "64759ea8-ca8d-455d-ad79-a86f6f4c1078", "name": "2f2a96b2-f5cc-4111-9081-3f1c4b1fe5cd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.981510789736824, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31377757670385525, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "22684b35-2628-4241-8a5b-8bb62902e667", "name": "ddc680e4-e90e-4c70-9b8a-9d25ea26c9d4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "64759ea8-ca8d-455d-ad79-a86f6f4c1078"}}}]}, {"uuid": "02800fdd-973c-4ea6-947e-16920dc24b19", "name": "load_p1rlv51_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ccef6af-4bf6-44dc-b292-2bf9503a374a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "22684b35-2628-4241-8a5b-8bb62902e667"}}}}, {"uuid": "d369ec5a-9562-4ae3-9425-61193f466f3d", "name": "7255ae90-e0cc-4211-a37d-c7c594174568_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.981510789736824, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31377757670385525, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b3a1c1ea-ecc3-4918-9a3e-a9f251be8050", "name": "ce92b254-0249-4534-aa24-f59f9a14d49e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d369ec5a-9562-4ae3-9425-61193f466f3d"}}}]}, {"uuid": "b960c0ed-e728-42b5-ac3e-4f16188cf698", "name": "load_p1rlv51_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ccef6af-4bf6-44dc-b292-2bf9503a374a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b3a1c1ea-ecc3-4918-9a3e-a9f251be8050"}}}}, {"uuid": "61de8132-a291-4b6f-b49b-0b80c583fa54", "name": "13eef270-75e1-49cd-8450-61946b6a081a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5300176124233262, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6781680527999017, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d2143736-d7cb-4e9f-afd6-b762c6c77b83", "name": "96862f7e-44cc-4402-84fc-0a409a7fa1cf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "61de8132-a291-4b6f-b49b-0b80c583fa54"}}}]}, {"uuid": "dc46ae74-9f32-4dee-a22d-5d2f43234fac", "name": "load_p1rlv52_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fec0a162-4b0c-4577-b878-8dbc7c9935fc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d2143736-d7cb-4e9f-afd6-b762c6c77b83"}}}}, {"uuid": "51693030-21ed-433c-b940-8ddbee99ba4d", "name": "94e31f3c-0b45-4c7f-bb84-7f07ffa8a8c2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5300176124233262, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6781680527999017, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "851be08c-93cb-4463-b140-7ed120d378ce", "name": "72332b31-1f7b-4287-a60c-aedf13b24f80", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "51693030-21ed-433c-b940-8ddbee99ba4d"}}}]}, {"uuid": "81a65548-4893-4ebc-9d8f-1b53055dd9e2", "name": "load_p1rlv52_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fec0a162-4b0c-4577-b878-8dbc7c9935fc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "851be08c-93cb-4463-b140-7ed120d378ce"}}}}, {"uuid": "6abbf5df-fbd7-4a80-b490-df552d7a8b46", "name": "b47ca072-cfb7-4733-ad27-193f2f0bfe6b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6434260893942235, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2588956175598443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9e94ad99-4c13-4173-a92b-b7a2de0883ad", "name": "bce8dc23-2a13-447a-9cdb-1cd11f8da7d6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6abbf5df-fbd7-4a80-b490-df552d7a8b46"}}}]}, {"uuid": "fef89029-ffd0-4547-be17-2f8e25fd98c1", "name": "load_p1rlv53_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3c62646-6132-41ef-ba14-a06789885cd5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9e94ad99-4c13-4173-a92b-b7a2de0883ad"}}}}, {"uuid": "052c9588-be83-4b6d-b4e1-ce941bdc6797", "name": "6598428b-fe64-4bf0-b56b-cdda485c2999_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6434260893942235, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2588956175598443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7c9ba43e-b36b-4613-b5a1-25f468b059aa", "name": "d65071fc-6b69-4311-919e-214df90c62b4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "052c9588-be83-4b6d-b4e1-ce941bdc6797"}}}]}, {"uuid": "36946610-1dcc-4134-898b-141d86caebe6", "name": "load_p1rlv53_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3c62646-6132-41ef-ba14-a06789885cd5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7c9ba43e-b36b-4613-b5a1-25f468b059aa"}}}}, {"uuid": "cd4813cb-75e1-4fd1-995f-64aef6215ba9", "name": "9791f066-d559-48f2-8046-be65a4f4d83d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0716401691896973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6949594139700135, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "58b06842-060e-44f2-9f15-d2251967f3b2", "name": "c7e96f2d-342a-4a67-b4cc-f82c59ede79a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cd4813cb-75e1-4fd1-995f-64aef6215ba9"}}}]}, {"uuid": "56cd5e9f-8740-49f4-bb1e-5f4d8f19cfd7", "name": "load_p1rlv54_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20010301-32ce-4cc0-ab59-04ef3bcd35d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "58b06842-060e-44f2-9f15-d2251967f3b2"}}}}, {"uuid": "9c30dcb0-c947-4edc-accb-c0a02c230337", "name": "27a47eaa-eb7a-462e-9760-416f68e5ac5f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0716401691896973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6949594139700135, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6ec27cbf-3b73-4702-b082-dd7b3b1f2564", "name": "d40e052a-8972-4156-910d-04ea499fcc4e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9c30dcb0-c947-4edc-accb-c0a02c230337"}}}]}, {"uuid": "b6b82de1-3192-4c3e-9309-5d13723dfe0d", "name": "load_p1rlv54_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20010301-32ce-4cc0-ab59-04ef3bcd35d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6ec27cbf-3b73-4702-b082-dd7b3b1f2564"}}}}, {"uuid": "fa51dbf9-43bf-446a-9e23-9efce2fb5435", "name": "55e2003d-1b32-40de-8240-29a1f5add95d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3786182488338723, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5359363058124609, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "da3ee55b-aa13-409a-b48a-99c1ccbc9b50", "name": "ef778de1-7ba1-488d-b6e6-68ce6932d203", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fa51dbf9-43bf-446a-9e23-9efce2fb5435"}}}]}, {"uuid": "2f30ac26-a181-4f7c-8a9b-67ee9ead036d", "name": "load_p1rlv55_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36bdbc4e-edfa-425a-8e4c-e6123b567555"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "da3ee55b-aa13-409a-b48a-99c1ccbc9b50"}}}}, {"uuid": "312bc123-0043-4a03-a59d-87fdba87803e", "name": "03cfedd2-dd35-417e-97af-1239244ed228_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3786182488338723, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5359363058124609, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "273079c0-858a-4afc-842d-2db5866bcf6a", "name": "5f32ef60-0009-4b89-ab29-c49613ccf917", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "312bc123-0043-4a03-a59d-87fdba87803e"}}}]}, {"uuid": "487a0692-f420-4664-ba69-a3aaef52c74e", "name": "load_p1rlv55_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36bdbc4e-edfa-425a-8e4c-e6123b567555"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "273079c0-858a-4afc-842d-2db5866bcf6a"}}}}, {"uuid": "0b790946-d246-4c1b-b6d6-0067e4edf3e2", "name": "819ed8f1-a309-4e64-b58c-d80fd571d234_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b87f61d9-a337-4489-9654-b435a567edda", "name": "91ecacfa-eeb4-463b-a4b8-65ff42bbf590", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0b790946-d246-4c1b-b6d6-0067e4edf3e2"}}}]}, {"uuid": "a7ceae31-cc7f-49f5-a440-9c93041c8419", "name": "load_p1rlv56_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4694811a-ba43-4c78-b957-5209b1d961e2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b87f61d9-a337-4489-9654-b435a567edda"}}}}, {"uuid": "4997efb3-15ef-42ea-8a37-5a1d0d1aae2a", "name": "08d09627-4dd8-4c74-91ab-32d60227f297_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6f4634be-569c-45ec-a487-1965bfde5f15", "name": "83670ef5-637f-41d3-b84c-b45d9db70a0c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4997efb3-15ef-42ea-8a37-5a1d0d1aae2a"}}}]}, {"uuid": "070e0bec-c5d5-4935-a573-6a66c8208aff", "name": "load_p1rlv56_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4694811a-ba43-4c78-b957-5209b1d961e2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6f4634be-569c-45ec-a487-1965bfde5f15"}}}}, {"uuid": "ffa4dcab-7823-4f11-bf6a-11622e0b391d", "name": "82fe1b29-d541-46e7-b4b4-8e6e83de5da7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.511185229285174, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8722130080127372, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "31ac6afe-5d0b-494a-b26a-64cf8af68dc9", "name": "c4bda4a5-c91e-4fb1-b56f-ceac0da95f0a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ffa4dcab-7823-4f11-bf6a-11622e0b391d"}}}]}, {"uuid": "eca7e6a5-2e72-498f-98d6-4eca7a795e56", "name": "load_p1rlv57_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "925cb3b7-4ced-4a36-913f-e6851ed79b98"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "31ac6afe-5d0b-494a-b26a-64cf8af68dc9"}}}}, {"uuid": "8aa935a4-9605-4cb6-a05a-b8ebe51f985f", "name": "1126d6d6-6c31-495d-a583-9f93adb3930d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.511185229285174, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8722130080127372, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "804e20fc-ab81-4717-9429-66555387373a", "name": "8ee07f7d-15e5-4163-93f6-810e6c316b6f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8aa935a4-9605-4cb6-a05a-b8ebe51f985f"}}}]}, {"uuid": "1f3e6253-b8e5-4ab5-bdfd-46f9af4444d3", "name": "load_p1rlv57_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "925cb3b7-4ced-4a36-913f-e6851ed79b98"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "804e20fc-ab81-4717-9429-66555387373a"}}}}, {"uuid": "7bfa137b-d37c-442b-ae63-6721da62faca", "name": "3192da5c-462e-401a-ad0d-4ba86cbbac55_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "128dcbb1-a554-4a8c-a0ef-3f10fc6ece9a", "name": "6f48bd8b-c745-40a4-849d-120e366ef0a5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7bfa137b-d37c-442b-ae63-6721da62faca"}}}]}, {"uuid": "c6258ea2-4e94-495b-adcc-c27da8522fb8", "name": "load_p1rlv58_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a32ee184-f677-4333-b7ee-7bc30ab41467"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "128dcbb1-a554-4a8c-a0ef-3f10fc6ece9a"}}}}, {"uuid": "fbb74d60-d121-4c49-a358-66d3b15539f3", "name": "9777a21c-8520-4b8f-94ab-3a37c0672550_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4991495076440033, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3360328736424813, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b3f31c27-b8c8-496c-a1c1-6f526e6e4732", "name": "c6816637-b73c-498b-9c46-71c14dd403a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fbb74d60-d121-4c49-a358-66d3b15539f3"}}}]}, {"uuid": "96d1444f-c24b-41c0-89f4-083ac4adab31", "name": "load_p1rlv58_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a32ee184-f677-4333-b7ee-7bc30ab41467"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b3f31c27-b8c8-496c-a1c1-6f526e6e4732"}}}}, {"uuid": "e84d0660-066d-48bc-802c-5cbe6cac2b47", "name": "7ad86ff7-eac6-485e-9469-bb1107c41554_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8939358223380807, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6690937458929831, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "55fe9328-dfab-47ae-939b-f73d69f8ee61", "name": "5e2d0fd5-190f-4dca-90ea-7b395e67f368", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e84d0660-066d-48bc-802c-5cbe6cac2b47"}}}]}, {"uuid": "acf318a8-c7db-41ba-a49a-0d3705a9601e", "name": "load_p1rlv59_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b80bdb24-4bbf-4a57-bd5f-6a5ec9d484dd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "55fe9328-dfab-47ae-939b-f73d69f8ee61"}}}}, {"uuid": "07378ae1-451f-4351-85fa-e652d35d8dbd", "name": "3020cb8a-bacd-4e6c-b4dc-9d71e3b2a96f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8939358223380807, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6690937458929831, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4be7d08b-7d54-4074-9279-18ddfbf4b64d", "name": "944dac61-6bb8-4e25-b5b8-0ac042289404", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "07378ae1-451f-4351-85fa-e652d35d8dbd"}}}]}, {"uuid": "8156076c-aeb1-483e-8f62-90c96d0db843", "name": "load_p1rlv59_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b80bdb24-4bbf-4a57-bd5f-6a5ec9d484dd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4be7d08b-7d54-4074-9279-18ddfbf4b64d"}}}}, {"uuid": "9fd2f010-f617-43a1-90da-a2983bd347c4", "name": "899e1c08-546f-46cd-b858-30141d86191d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1603354468169496, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7593773040340845, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7ffe70a7-2162-4583-80f7-e23d5e9296ff", "name": "da86087f-0581-442c-ae58-fb5788a8094e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9fd2f010-f617-43a1-90da-a2983bd347c4"}}}]}, {"uuid": "40f63329-991b-4813-a3d9-3c0a33f74e01", "name": "load_p1rlv60_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7eb0d1e8-f85e-493e-b69b-26437fdb8ad9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7ffe70a7-2162-4583-80f7-e23d5e9296ff"}}}}, {"uuid": "dc057a50-c489-4f71-97d1-ad27dabaf0d4", "name": "feccd281-58a7-44c6-acad-281c415ca87d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1603354468169496, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7593773040340845, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d548187e-8179-4289-8ff0-3f449d1423ab", "name": "ffa07784-97a4-4bb1-aee9-d15a204eab67", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dc057a50-c489-4f71-97d1-ad27dabaf0d4"}}}]}, {"uuid": "59d7a530-4a41-4dca-a713-21c2102fdf1f", "name": "load_p1rlv60_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7eb0d1e8-f85e-493e-b69b-26437fdb8ad9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d548187e-8179-4289-8ff0-3f449d1423ab"}}}}, {"uuid": "ff35e51b-04ff-4f09-b482-99c27f5da1f3", "name": "f3126d12-75df-4d11-aa4a-a9c08cb9733f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9029063430901945, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8881818750925909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "329ffebf-7a8b-4470-ba34-ac91d74aa28b", "name": "2e847882-3c19-42d4-b0b9-2fdb6d848b33", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ff35e51b-04ff-4f09-b482-99c27f5da1f3"}}}]}, {"uuid": "c5b6c803-9bdd-4411-9f38-652d7968ea5a", "name": "load_p1rlv61_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d22bf2f5-74cc-47c7-ae3b-410fba27c113"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "329ffebf-7a8b-4470-ba34-ac91d74aa28b"}}}}, {"uuid": "8ce51ded-7745-44fc-9206-13f7b36d6891", "name": "3a2fdfa3-b04e-43f7-a3f9-18dc7f50dce9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9029063430901945, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8881818750925909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8210ad11-07f5-4373-9f5d-e77c22d9abef", "name": "c1260533-0133-42de-b91c-5b0f83659704", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ce51ded-7745-44fc-9206-13f7b36d6891"}}}]}, {"uuid": "578e25d2-3757-46ed-889a-360cc36ff3a2", "name": "load_p1rlv61_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d22bf2f5-74cc-47c7-ae3b-410fba27c113"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8210ad11-07f5-4373-9f5d-e77c22d9abef"}}}}, {"uuid": "3c87086a-2cd0-4d24-ab10-d38c58d4b720", "name": "76ddcb3d-8614-4e58-8f65-6f687775ca97_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4622944887503224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10483650830237357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5a347ad2-b6db-42a6-afdf-d1a8a92880b2", "name": "596a8497-bd49-420e-be09-72d24a3a98b7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3c87086a-2cd0-4d24-ab10-d38c58d4b720"}}}]}, {"uuid": "66875e4d-eb39-46ea-a39f-ee24343197db", "name": "load_p1rlv62_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "346dad85-3bf8-41a6-97ea-6b3b40a7f22e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5a347ad2-b6db-42a6-afdf-d1a8a92880b2"}}}}, {"uuid": "100071b2-0732-4f24-8a62-8be1cac1ccdf", "name": "6fdbc8d9-0d4c-4c6f-8661-8f6efc71b762_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4622944887503224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10483650830237357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "44334bee-647e-482e-b736-2ee9d2617deb", "name": "5338051a-88f9-4394-9b46-461b8ba3d191", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "100071b2-0732-4f24-8a62-8be1cac1ccdf"}}}]}, {"uuid": "04f417f8-f826-4bd9-b00e-01479da822d7", "name": "load_p1rlv62_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "346dad85-3bf8-41a6-97ea-6b3b40a7f22e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "44334bee-647e-482e-b736-2ee9d2617deb"}}}}, {"uuid": "8599c743-3264-4e27-b07b-8e70f18fc831", "name": "a4e57bc0-47f2-442e-916e-f28a36b42111_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7083181921938193, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5666922324635131, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "898bad6c-4120-423c-a19a-20da7d4feb01", "name": "5af4bc67-65a3-4da2-b651-b3acc3aef15f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8599c743-3264-4e27-b07b-8e70f18fc831"}}}]}, {"uuid": "78f2f1fb-da78-4ba9-9ad8-070d19f70556", "name": "load_p1rlv63_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8300f90c-9a3b-400d-af04-072125dce84f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "898bad6c-4120-423c-a19a-20da7d4feb01"}}}}, {"uuid": "01f9af62-6d2a-496a-bc8c-344e644cdf96", "name": "28c9d240-6539-4301-8c02-f9fdf480e77a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7083181921938193, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5666922324635131, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "86f365c8-5fb9-4b3e-b9de-50644f943c86", "name": "895b62dd-e0d9-407c-8610-7c3f92f4726a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "01f9af62-6d2a-496a-bc8c-344e644cdf96"}}}]}, {"uuid": "27a20244-06ca-45c4-9084-e1fcc1951a4c", "name": "load_p1rlv63_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8300f90c-9a3b-400d-af04-072125dce84f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "86f365c8-5fb9-4b3e-b9de-50644f943c86"}}}}, {"uuid": "b862f914-18e8-4f3f-a2ab-b4004b0a270c", "name": "c970302a-774f-49bf-b5e0-c2b30e2d230f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "07dab6b3-42a2-4c75-b6aa-e203b274546a", "name": "27d68dc6-3c92-412f-8cd5-96a426254f98", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b862f914-18e8-4f3f-a2ab-b4004b0a270c"}}}]}, {"uuid": "0ad073d3-f5f3-49ce-b085-f94653b6a7b8", "name": "load_p1rlv64_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5efd07ee-012a-40a4-97bb-07c1a5ed898c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "07dab6b3-42a2-4c75-b6aa-e203b274546a"}}}}, {"uuid": "3834f18a-3307-46e7-b128-2cb05ee29fdf", "name": "f42af146-ac7b-40bc-9d07-dc48db61df81_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "70b7f579-bc96-4d4f-8e5b-2676ad9989e2", "name": "35679726-0cd8-413c-9bb7-e7e069ee3ab3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3834f18a-3307-46e7-b128-2cb05ee29fdf"}}}]}, {"uuid": "62f41ebe-0ac1-445e-aa1c-f1b1ee6206c2", "name": "load_p1rlv64_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5efd07ee-012a-40a4-97bb-07c1a5ed898c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "70b7f579-bc96-4d4f-8e5b-2676ad9989e2"}}}}, {"uuid": "59222fb2-eed2-4531-886d-4ab391f26fd8", "name": "a4f53f0f-efda-4c30-9c32-c8d0501a6236_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.987999469244499, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42543082019456707, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aef24bb2-0143-4d23-b28f-76869b6f4d9d", "name": "def2e903-ba3c-4a94-a5f9-dc2fa49a6e46", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "59222fb2-eed2-4531-886d-4ab391f26fd8"}}}]}, {"uuid": "9efc84d7-f9d5-4795-8efd-d75517ccc450", "name": "load_p1rlv65_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e00fd9b-92b3-49c4-bcc2-957b9d2c7bad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aef24bb2-0143-4d23-b28f-76869b6f4d9d"}}}}, {"uuid": "ec001aa8-96b4-426f-ae24-a955358fb564", "name": "006c88d4-217f-4d52-b295-77ce7136abec_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.987999469244499, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42543082019456707, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5575b206-a4d9-4886-b943-6f83eb2da744", "name": "71eb4998-e8dc-46bd-983e-8f6ed559d229", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ec001aa8-96b4-426f-ae24-a955358fb564"}}}]}, {"uuid": "53fe26dd-75ad-46a7-ab2a-913f6a4efeb5", "name": "load_p1rlv65_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e00fd9b-92b3-49c4-bcc2-957b9d2c7bad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5575b206-a4d9-4886-b943-6f83eb2da744"}}}}, {"uuid": "afaef95b-19ae-4d4c-9bd7-29a86ae18b21", "name": "206317db-612b-4704-927f-fbf96927fc4e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4760012569901637, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5456626743322578, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "318e8349-3abc-4e20-b2d2-61184ad007af", "name": "12335a28-a671-4308-894b-a566e26d5169", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "afaef95b-19ae-4d4c-9bd7-29a86ae18b21"}}}]}, {"uuid": "601e7dc9-3f13-4d78-9de3-cac4d1420926", "name": "load_p1rlv66_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e90eb8a2-5db0-4861-96ef-a6991a0386eb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "318e8349-3abc-4e20-b2d2-61184ad007af"}}}}, {"uuid": "1ffcaa05-a532-4271-a582-0ef155917abf", "name": "98dda52b-a2a6-48d9-9ab8-0cb3f98c2c57_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4760012569901637, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5456626743322578, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c9ac0b1d-2a67-4235-b228-a001c83548de", "name": "51011efb-57db-45c9-b4c6-a38f0d590ca6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1ffcaa05-a532-4271-a582-0ef155917abf"}}}]}, {"uuid": "ca7d9648-ce04-409b-a2cb-3c41f2fd3466", "name": "load_p1rlv66_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e90eb8a2-5db0-4861-96ef-a6991a0386eb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c9ac0b1d-2a67-4235-b228-a001c83548de"}}}}, {"uuid": "01480de0-d6dc-4f77-b6fd-baec76795330", "name": "910685f4-8a79-4fb1-8e40-76a0dbc16746_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3018265224045242, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4135325648663858, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "48caeb22-cef1-44ce-8b7f-334baa96534a", "name": "deaf7d4c-d47c-456a-84d0-9426b6fa3647", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "01480de0-d6dc-4f77-b6fd-baec76795330"}}}]}, {"uuid": "56967678-ef97-4b84-8234-803c2743fc1d", "name": "load_p1rlv67_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64a67ed2-a563-4378-b6ac-d9a95339e862"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "48caeb22-cef1-44ce-8b7f-334baa96534a"}}}}, {"uuid": "b4172dd9-f9b8-41e5-99d2-3d6915d07d17", "name": "dc492572-240c-40df-9781-57f5e10675f7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3018265224045242, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4135325648663858, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0f4419de-9c75-4f53-8c77-250c21b8d5a6", "name": "22ea51f2-fbaa-46da-bb8e-d4317fbffd90", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b4172dd9-f9b8-41e5-99d2-3d6915d07d17"}}}]}, {"uuid": "fe5c82ba-f77a-4a58-b55b-703dbebd90a2", "name": "load_p1rlv67_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64a67ed2-a563-4378-b6ac-d9a95339e862"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0f4419de-9c75-4f53-8c77-250c21b8d5a6"}}}}, {"uuid": "7ada4d37-f4d3-40ed-9acd-d5faba481be4", "name": "e25d5b2a-2237-4c29-8fe4-17b6a3691be9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0137187800791063, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5284248988065299, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "543d61c1-6beb-4d3f-ad74-6ac05c55b839", "name": "585ee9d5-3a0b-4e15-af3a-7f3d401331c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7ada4d37-f4d3-40ed-9acd-d5faba481be4"}}}]}, {"uuid": "349f2751-aa29-4c04-984e-19e73fec0a3e", "name": "load_p1rlv68_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c22aa2c8-a6fc-4b27-a875-e07e3f50ecac"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "543d61c1-6beb-4d3f-ad74-6ac05c55b839"}}}}, {"uuid": "2b5d429b-3513-498e-95c9-5e9dcf8f77f7", "name": "13fb1350-2b2d-47f8-94b4-f87982450d96_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0137187800791063, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5284248988065299, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eacc52d2-bcce-4dcc-b6fa-08595047ae7b", "name": "246247a2-c496-41cf-88df-973e7f0884ee", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2b5d429b-3513-498e-95c9-5e9dcf8f77f7"}}}]}, {"uuid": "bc8c3905-1e5c-4811-9bfd-9689ad2d7792", "name": "load_p1rlv68_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c22aa2c8-a6fc-4b27-a875-e07e3f50ecac"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eacc52d2-bcce-4dcc-b6fa-08595047ae7b"}}}}, {"uuid": "fdb23bcf-6111-45ce-ba6c-9007569fce0e", "name": "3808ebb1-face-4a6e-ac7a-7c748c7b669e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7457942211533133, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8784341351558463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b97a3dfb-cc9f-4973-ba82-2213198cebe0", "name": "6768ceee-43be-427e-942b-0db671a29204", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fdb23bcf-6111-45ce-ba6c-9007569fce0e"}}}]}, {"uuid": "efaa2824-5c5f-4090-a1d0-e423cd416f50", "name": "load_p1rlv69_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "876ffb0b-f33c-45b2-a085-7b34103ecffc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b97a3dfb-cc9f-4973-ba82-2213198cebe0"}}}}, {"uuid": "4bc44e80-80e4-4ce6-ac5f-0c25e7ec3613", "name": "34f1e2e2-5b8c-4c0c-bff0-c252aa0692cb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7457942211533133, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8784341351558463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7c06383e-92cc-4e56-819a-5e3f04c47953", "name": "851c42dc-9eee-420a-b9f2-c2aaf0f5858d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4bc44e80-80e4-4ce6-ac5f-0c25e7ec3613"}}}]}, {"uuid": "4e205fd5-defb-40c6-9ee3-9503b82895d3", "name": "load_p1rlv69_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "876ffb0b-f33c-45b2-a085-7b34103ecffc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7c06383e-92cc-4e56-819a-5e3f04c47953"}}}}, {"uuid": "9318faf6-43f3-4b64-b795-832075723229", "name": "db559aeb-98cf-423d-a41a-7164ba97f874_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9024769844937937, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4778358547008617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eba25c14-7d83-4638-8dd7-0112ebd2975b", "name": "1b4e6b62-4c77-4826-a67a-a1f3ff117cd5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9318faf6-43f3-4b64-b795-832075723229"}}}]}, {"uuid": "b67279ba-f49e-43db-945d-e40605cabca3", "name": "load_p1rlv70_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e53e7714-06d1-4f85-89c5-f152629e8ab7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eba25c14-7d83-4638-8dd7-0112ebd2975b"}}}}, {"uuid": "051edfd9-73cd-4d9e-b201-66ecec1ba31a", "name": "23733246-02ee-4dbb-81e6-1328a944508e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9024769844937937, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4778358547008617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f696d473-ce5b-47cc-b65b-283c16067c2a", "name": "b6029e0d-b18c-45df-bae2-892a50823b72", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "051edfd9-73cd-4d9e-b201-66ecec1ba31a"}}}]}, {"uuid": "aa5c61af-18a1-453f-a3f4-a01a6ff35a85", "name": "load_p1rlv70_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e53e7714-06d1-4f85-89c5-f152629e8ab7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f696d473-ce5b-47cc-b65b-283c16067c2a"}}}}, {"uuid": "a5d6224c-b3d0-431d-9687-6aee701eed15", "name": "dcae4974-9e3e-475f-a5f0-c032a786fb75_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.67620786252276, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6753067705079763, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e8511645-a7d1-4737-8cc2-82d08e7818e6", "name": "437ee150-f220-427c-b24f-f817c64d804c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a5d6224c-b3d0-431d-9687-6aee701eed15"}}}]}, {"uuid": "753210c9-2537-407d-8134-f6994ae34c0f", "name": "load_p1rlv71_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d7791de-0cf6-4901-8b95-2d67870f09f5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e8511645-a7d1-4737-8cc2-82d08e7818e6"}}}}, {"uuid": "932477c7-093b-4a62-a26c-00c103b7afb4", "name": "c0c3200b-1955-40cd-a5ec-d8b3427fb9e7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.67620786252276, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6753067705079763, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1979701e-0c8f-4afd-82d1-72025b72e5b5", "name": "8fc03c47-5d22-4a89-ab4e-017f7f49625f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "932477c7-093b-4a62-a26c-00c103b7afb4"}}}]}, {"uuid": "f1e0849b-033d-4707-a5da-2f479ad9b242", "name": "load_p1rlv71_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d7791de-0cf6-4901-8b95-2d67870f09f5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1979701e-0c8f-4afd-82d1-72025b72e5b5"}}}}, {"uuid": "171f09a9-7d92-4ebd-bc33-a8ce323d7740", "name": "601db640-ac9c-4700-8e3d-ce9c23046380_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7083181921938193, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5666922324635131, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "64770796-9427-46e0-87b6-dba6df0d845f", "name": "0b8bba1b-3692-4a6b-9087-cacf89b0b8c6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "171f09a9-7d92-4ebd-bc33-a8ce323d7740"}}}]}, {"uuid": "73bd524a-2a7b-4850-9219-476e289e193a", "name": "load_p1rlv72_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc710fc3-ae5f-478e-997b-85467db7c93c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "64770796-9427-46e0-87b6-dba6df0d845f"}}}}, {"uuid": "18482ac3-1e93-4767-965b-b1551c7ec390", "name": "17d289a0-09c1-4ba9-8024-35bf760e95dd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7083181921938193, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5666922324635131, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e2005fa8-788f-49f4-a6fc-2a3fcb0789b1", "name": "30d7102e-5d90-496d-b7b2-5d74ecb4c561", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "18482ac3-1e93-4767-965b-b1551c7ec390"}}}]}, {"uuid": "2f4bbdec-435b-4b1c-b766-2dc3fd9d6b0b", "name": "load_p1rlv72_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc710fc3-ae5f-478e-997b-85467db7c93c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e2005fa8-788f-49f4-a6fc-2a3fcb0789b1"}}}}, {"uuid": "95a44352-4c4c-4538-a12b-b845882ef1b0", "name": "5dfa04b0-3d87-4fcf-89d3-d2d88f53864c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9051339071763382, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34139556761684264, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c1da838c-955a-49f5-96d2-5b319c046b1b", "name": "6cb71f3e-84ab-4eb1-8d64-e94b484e234f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "95a44352-4c4c-4538-a12b-b845882ef1b0"}}}]}, {"uuid": "72d6dc0d-dbd3-4ed7-99c7-a9079120b408", "name": "load_p1rlv73_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4e2991c-1404-44da-bbb5-5a2ebc43bde4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c1da838c-955a-49f5-96d2-5b319c046b1b"}}}}, {"uuid": "09f3f48f-ccec-44e7-945e-17e6b940dae3", "name": "637008f6-2fb8-4ce9-b3c3-4d5fdb03370d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9051339071763382, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34139556761684264, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8dad0dd4-67e1-45e0-8d3f-29b4204c8f7a", "name": "ba48f13c-9b3f-4f92-bf0f-c05e4b1713f8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "09f3f48f-ccec-44e7-945e-17e6b940dae3"}}}]}, {"uuid": "2c9f38cb-dd0e-47c2-8989-5b42a798d63b", "name": "load_p1rlv73_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4e2991c-1404-44da-bbb5-5a2ebc43bde4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8dad0dd4-67e1-45e0-8d3f-29b4204c8f7a"}}}}, {"uuid": "aced7483-5ca3-4fe3-9a80-7ad42326f6b3", "name": "eeff11e3-ccc5-4d5b-8432-d16b4d08dda8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.4509454152189125, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9978822313633423, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1066ce43-8f62-4734-b2f1-0d2d4e925c63", "name": "e1e3028b-662a-4460-aee6-532ec71815f3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aced7483-5ca3-4fe3-9a80-7ad42326f6b3"}}}]}, {"uuid": "79acc9d8-71a7-41c0-a471-9d9f27e2d3fc", "name": "load_p1rlv74_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5861410e-9d6d-423e-b967-2f2af65610b8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1066ce43-8f62-4734-b2f1-0d2d4e925c63"}}}}, {"uuid": "60451775-92b6-4bf4-9f2c-5448fe20d483", "name": "6d5fcafa-ab52-4b90-a0e2-edcb0734040a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.4509454152189125, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9978822313633423, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "343a81e9-b88c-4f56-8722-4252ebf06a78", "name": "07205db1-1d6a-4850-8bd6-bca3b295fa0e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "60451775-92b6-4bf4-9f2c-5448fe20d483"}}}]}, {"uuid": "dad038de-44f9-459a-bb66-d26063065fe2", "name": "load_p1rlv74_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5861410e-9d6d-423e-b967-2f2af65610b8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "343a81e9-b88c-4f56-8722-4252ebf06a78"}}}}, {"uuid": "e6727a08-79b7-4316-b1fb-92835a5f95c5", "name": "2ead64c7-e386-418d-8808-33609a3ceda3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6211116916449642, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3778136238343289, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8e88cc6c-66b8-49cf-a605-634760d875b6", "name": "d71f38b7-e1be-4217-bdd4-9bf759822e90", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e6727a08-79b7-4316-b1fb-92835a5f95c5"}}}]}, {"uuid": "bd3d2042-a713-4793-9d03-bf8942a59c48", "name": "load_p1rlv75_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ef51371-3fa2-400a-a2b4-3afa97ff2419"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8e88cc6c-66b8-49cf-a605-634760d875b6"}}}}, {"uuid": "7b61b33f-2010-4907-8271-5ff87054e074", "name": "1e148a6c-faa9-4a61-950f-6fd0b951acd4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6211116916449642, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3778136238343289, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "008bf0e6-0413-4467-8e83-1c8f960b4d47", "name": "99b717d0-dd73-4623-a3ab-281f3b99990e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b61b33f-2010-4907-8271-5ff87054e074"}}}]}, {"uuid": "cf336d44-81c4-4f45-81a3-dd94dada5711", "name": "load_p1rlv75_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ef51371-3fa2-400a-a2b4-3afa97ff2419"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "008bf0e6-0413-4467-8e83-1c8f960b4d47"}}}}, {"uuid": "401ab11c-c2ca-4af5-83c5-07c0363178e9", "name": "29ee0be8-831d-4de6-9384-3a20b0130b9b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9972586284721718, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5405993695804993, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8aa83d12-59f5-4bd1-9bab-eb86f3b8f9cd", "name": "49ad30de-c56a-46fa-b952-3da284311066", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "401ab11c-c2ca-4af5-83c5-07c0363178e9"}}}]}, {"uuid": "86acebf5-6adf-437e-bb88-4355e0a18752", "name": "load_p1rlv76_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3354497f-6de7-405d-9fca-a9c77463dc27"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8aa83d12-59f5-4bd1-9bab-eb86f3b8f9cd"}}}}, {"uuid": "a2bc55db-41cc-4697-9041-f6afcc88f075", "name": "5192ad56-41bf-4e17-ba69-df91196fded9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9972586284721718, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5405993695804993, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "212c4d7c-ce43-4ee7-99ea-d311eeb73f6b", "name": "46651f50-b9b3-4d1a-ab92-766edd5c0ea7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a2bc55db-41cc-4697-9041-f6afcc88f075"}}}]}, {"uuid": "829a24fa-03e0-4bb7-85bd-18af6a600c59", "name": "load_p1rlv76_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3354497f-6de7-405d-9fca-a9c77463dc27"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "212c4d7c-ce43-4ee7-99ea-d311eeb73f6b"}}}}, {"uuid": "907cd593-47d9-414c-9363-fc74d801bac8", "name": "5670f2ba-5ba8-4ff2-ac56-2b3074e6c8bc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5906266465914705, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5909884959248153, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "242af08d-0057-4a60-ad70-584db34fe2da", "name": "3bffc9ae-98d9-4564-a1d7-a2043f167347", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "907cd593-47d9-414c-9363-fc74d801bac8"}}}]}, {"uuid": "5b1e63c2-8a7f-49e8-81b4-33c812d96e66", "name": "load_p1rlv77_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f88a22a3-7e6c-4fc5-a8f4-a08cdaa3f5d6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "242af08d-0057-4a60-ad70-584db34fe2da"}}}}, {"uuid": "6c51c685-cd8d-428b-961a-6e577b49da69", "name": "c153e376-cd37-4afd-a4f0-44059fb3bd42_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5906266465914705, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5909884959248153, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f034abf0-9bf2-432b-9076-d81d579ab322", "name": "87ae233a-d756-446d-b7c6-f68f6b8809a8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c51c685-cd8d-428b-961a-6e577b49da69"}}}]}, {"uuid": "863be99e-0075-4534-ac07-5c38053fd75f", "name": "load_p1rlv77_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f88a22a3-7e6c-4fc5-a8f4-a08cdaa3f5d6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f034abf0-9bf2-432b-9076-d81d579ab322"}}}}, {"uuid": "e00ae0f3-c833-4c32-bc1b-62e2800b2ae3", "name": "54b10842-69f3-44d3-983a-1e05f6d6847e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.307297155025492, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20108954410245963, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "49074f23-3cec-4e91-8619-29b4df38c43f", "name": "954509de-44bf-4a2f-adb7-3266478e3ce0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e00ae0f3-c833-4c32-bc1b-62e2800b2ae3"}}}]}, {"uuid": "7ccb5eb7-4b8e-4d08-ba79-67b2d36c0e28", "name": "load_p1rlv78_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae76f058-b79a-4c0f-90be-f9cd7a02bcfc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "49074f23-3cec-4e91-8619-29b4df38c43f"}}}}, {"uuid": "513edbe7-9f8a-47e7-b306-d5ee792f8316", "name": "3fd72f79-30f1-4872-b8ce-b5bf993ace92_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.307297155025492, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20108954410245963, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "67d51062-6006-4e4b-870e-daf7b42dd301", "name": "25a078b4-10c4-4992-ab76-c8d1267af0e8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "513edbe7-9f8a-47e7-b306-d5ee792f8316"}}}]}, {"uuid": "01058f72-29ef-4ad0-ac3b-29577e185af8", "name": "load_p1rlv78_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae76f058-b79a-4c0f-90be-f9cd7a02bcfc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "67d51062-6006-4e4b-870e-daf7b42dd301"}}}}, {"uuid": "f6a96aff-44b9-4310-8cec-c6c2b14b33a8", "name": "b7379432-13b6-4763-a2ca-4bbfbad3f8fb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3315344999322854, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13574204648198762, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1d093d27-94a2-420f-9153-e4364aa561fe", "name": "bdb6170b-c44d-4582-8da9-2ce5e6b2894e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f6a96aff-44b9-4310-8cec-c6c2b14b33a8"}}}]}, {"uuid": "c2d61fb1-e7cb-4984-9dd4-61311694f5ff", "name": "load_p1rlv79_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4dd2283-6100-48ce-b4bc-0e37b7b4e409"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1d093d27-94a2-420f-9153-e4364aa561fe"}}}}, {"uuid": "7e58475c-002a-4f30-8c93-c7f602f794bf", "name": "af5fd900-aa6b-47ea-8c41-bcdfb62950b1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3315344999322854, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13574204648198762, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "678e4c04-ef44-4a06-ad06-ecd15fc903b3", "name": "45d74966-1781-49fc-9ee4-83e8c62a0e43", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7e58475c-002a-4f30-8c93-c7f602f794bf"}}}]}, {"uuid": "90b6d2ad-8447-41d3-8410-66bc45c0a8c4", "name": "load_p1rlv79_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4dd2283-6100-48ce-b4bc-0e37b7b4e409"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "678e4c04-ef44-4a06-ad06-ecd15fc903b3"}}}}, {"uuid": "8e73e272-ff08-4f45-ba2f-09fc3e5a8fa5", "name": "8c8ae855-b307-4833-a21c-c40bc511bc49_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.949137985829372, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.575540256876006, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6bea2e1f-72c3-4820-ab6e-e50a770156b9", "name": "289ae79d-4446-4fa2-afb5-8bda2d97054e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8e73e272-ff08-4f45-ba2f-09fc3e5a8fa5"}}}]}, {"uuid": "36240d9c-fa6e-4e7c-8806-54998ae16ba6", "name": "load_p1rlv80_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab7e1b4a-f8ec-4211-b7a0-d7f9057f576a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6bea2e1f-72c3-4820-ab6e-e50a770156b9"}}}}, {"uuid": "56d0a40d-1c01-4253-bd49-17a4ff33393f", "name": "6bde1f81-0fb4-4d6c-bcb2-37ff2712533a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.949137985829372, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.575540256876006, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8c2651f3-50f5-46e6-9e5f-1325b9300ce7", "name": "3a1244f7-b0f9-41df-9551-4a5222d91c23", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "56d0a40d-1c01-4253-bd49-17a4ff33393f"}}}]}, {"uuid": "9f53e5b8-cc13-4f88-8d06-dbf7d9f9250d", "name": "load_p1rlv80_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab7e1b4a-f8ec-4211-b7a0-d7f9057f576a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8c2651f3-50f5-46e6-9e5f-1325b9300ce7"}}}}, {"uuid": "dacbc3fd-e8fc-41e1-979a-f31318a804a7", "name": "1216a7da-abd7-4d65-893a-79470bfa76d5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.94390101914808, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4734308884348923, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "64d85114-19cb-4b9c-87b4-d99dd2964eb7", "name": "3aebcaa7-c27a-4c99-9dd4-d9ff99542bf0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dacbc3fd-e8fc-41e1-979a-f31318a804a7"}}}]}, {"uuid": "9b5ab49d-17fc-4a4b-824e-c2fd0dc8bc23", "name": "load_p1rlv81_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef92e40c-fe3c-4f7f-b844-884e1079e491"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "64d85114-19cb-4b9c-87b4-d99dd2964eb7"}}}}, {"uuid": "da745182-9985-4a61-8f4e-b5de2ad03235", "name": "46efe056-862e-4385-a344-c132c8299364_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.94390101914808, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4734308884348923, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ee387653-80e7-474e-846c-81b5f5b6a6d2", "name": "26c2ebf2-3c81-4891-8188-e08d41dd10a8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "da745182-9985-4a61-8f4e-b5de2ad03235"}}}]}, {"uuid": "f89298d2-b950-41d4-8276-101df4186a6e", "name": "load_p1rlv81_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef92e40c-fe3c-4f7f-b844-884e1079e491"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ee387653-80e7-474e-846c-81b5f5b6a6d2"}}}}, {"uuid": "af5a52a2-3fe9-4359-93fd-d55143549a28", "name": "1d6d2c06-1203-4968-ac98-b4d4ac8dc5b7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8534881847076217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.812795269620709, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "38eab04b-b674-49e4-bc32-07f6e0824eab", "name": "4e16fa12-982b-48ad-a47a-f250918d5af4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "af5a52a2-3fe9-4359-93fd-d55143549a28"}}}]}, {"uuid": "a62a54a5-6697-443b-a32b-361d4df7db89", "name": "load_p1rlv82_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3ddd704-2530-4392-8e9e-06e047b12f41"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "38eab04b-b674-49e4-bc32-07f6e0824eab"}}}}, {"uuid": "58a22351-641e-471f-8761-366370ea2434", "name": "c93e98c4-b94c-4d47-ae80-bd03cfe25cb2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8534881847076217, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.812795269620709, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6fc40c4f-722e-4b46-a59a-49a12373a9cb", "name": "97c7b1a9-89fd-4b27-a3af-81893c03fdeb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58a22351-641e-471f-8761-366370ea2434"}}}]}, {"uuid": "8859a756-2afb-4ba2-b94c-856c2e66a892", "name": "load_p1rlv82_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3ddd704-2530-4392-8e9e-06e047b12f41"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6fc40c4f-722e-4b46-a59a-49a12373a9cb"}}}}, {"uuid": "6bd10507-5bba-4bd0-bef6-a72f290a6b67", "name": "6f2028c5-16e7-4328-8e03-13bf0033686e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.67620786252276, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6753067705079763, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b953ab0d-ba0c-4318-a252-6adef9567579", "name": "f4a2ebc7-287c-4c3b-a6f6-f3ce4a3586f1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6bd10507-5bba-4bd0-bef6-a72f290a6b67"}}}]}, {"uuid": "7665a9b0-76d2-400a-96c0-6f0990926a37", "name": "load_p1rlv83_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24c3e8d8-1520-4a05-84af-a70da6140b4d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b953ab0d-ba0c-4318-a252-6adef9567579"}}}}, {"uuid": "f70363eb-715d-40c7-a5fc-d7a56e04daf3", "name": "ef0c837c-6f9d-47a1-b498-882f08d091ce_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.67620786252276, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6753067705079763, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "78a15a68-4494-4c64-a4d8-7922e66e8997", "name": "f00b83e2-3f0d-4136-bbee-68ce5e3fc5c8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f70363eb-715d-40c7-a5fc-d7a56e04daf3"}}}]}, {"uuid": "88b75824-d49f-4113-a8c6-40ab676f6052", "name": "load_p1rlv83_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24c3e8d8-1520-4a05-84af-a70da6140b4d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "78a15a68-4494-4c64-a4d8-7922e66e8997"}}}}, {"uuid": "ad189afa-a8cc-4feb-aac9-4d99560096bb", "name": "e8272f62-d3e6-4e83-875d-129826f5a230_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2851011950034972, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5829386425893015, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "acd82457-1844-4bec-8ac5-5a37bf06e070", "name": "0374fa7b-d2bf-45ee-b82d-3ce35d0efd09", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ad189afa-a8cc-4feb-aac9-4d99560096bb"}}}]}, {"uuid": "051b254a-b970-418d-92f0-2373c3f21681", "name": "load_p1rlv84_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "55e7538f-4bde-4810-a237-ac0cad7ba805"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "acd82457-1844-4bec-8ac5-5a37bf06e070"}}}}, {"uuid": "1b337f5d-481e-47a9-94e2-6c18b30933c2", "name": "54310b84-29a0-4191-990c-fc85dcf39f15_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2851011950034972, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5829386425893015, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fb46c6ba-5700-4c6f-9aca-52a6c4a67e00", "name": "ad3546ac-85e1-4a6a-be55-77848057669d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1b337f5d-481e-47a9-94e2-6c18b30933c2"}}}]}, {"uuid": "11d28132-44eb-4000-b730-9f6b60fb5574", "name": "load_p1rlv84_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "55e7538f-4bde-4810-a237-ac0cad7ba805"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fb46c6ba-5700-4c6f-9aca-52a6c4a67e00"}}}}, {"uuid": "8ea51f72-6007-45f2-934c-ee720a2a2a6d", "name": "e93d34db-209b-410b-99e8-74e2a10f1f24_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.904546554088597, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7711735109904765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ccf23164-9fe3-498a-8339-0cd4afaaac3b", "name": "34eb3b6c-c8a2-40b9-b54c-561072b6b44d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ea51f72-6007-45f2-934c-ee720a2a2a6d"}}}]}, {"uuid": "23d33e7c-c398-44ea-9d3b-24dfc98d40c8", "name": "load_p1rlv85_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcc52dd9-bacb-4e49-a057-d3747f89a7f7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ccf23164-9fe3-498a-8339-0cd4afaaac3b"}}}}, {"uuid": "55918753-a6a5-4ae9-a332-7fe46c0295e7", "name": "d5657e75-94e2-4bd5-9b06-70f7046f60c4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.904546554088597, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7711735109904765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7069ce04-1c39-41c2-be08-6a3ca23bbda5", "name": "a581fb52-0345-443c-8a00-55901ea16962", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "55918753-a6a5-4ae9-a332-7fe46c0295e7"}}}]}, {"uuid": "c4dba301-7f1a-4f27-a876-cf8834058be0", "name": "load_p1rlv85_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcc52dd9-bacb-4e49-a057-d3747f89a7f7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7069ce04-1c39-41c2-be08-6a3ca23bbda5"}}}}, {"uuid": "35c623f4-72bb-454f-917f-134d2d188e73", "name": "b7492d0b-7810-4e67-b9ff-6ba1915425df_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8309189378455104, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6069744647018672, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c1b59f56-d91c-4edc-bdb4-5b6d88df2d73", "name": "17d3e626-6bd6-420f-b575-cfec57187186", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "35c623f4-72bb-454f-917f-134d2d188e73"}}}]}, {"uuid": "78febb96-7b66-4d6e-941a-633a0723f10e", "name": "load_p1rlv86_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "540e0121-fc39-4c2c-9fbc-012c020f5994"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c1b59f56-d91c-4edc-bdb4-5b6d88df2d73"}}}}, {"uuid": "cb5d3869-1d7a-4b61-85bd-8d1a5aa2b9dd", "name": "93bb007f-267b-4671-9657-383b7126fe63_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8309189378455104, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6069744647018672, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e4bbaed5-dcd9-4e1e-868b-1af88726dd4e", "name": "175acd64-2275-44e6-bd26-30a79b5a1ec6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cb5d3869-1d7a-4b61-85bd-8d1a5aa2b9dd"}}}]}, {"uuid": "9b25e5dd-b353-4e2b-bdd0-8b2f40cc299b", "name": "load_p1rlv86_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "540e0121-fc39-4c2c-9fbc-012c020f5994"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e4bbaed5-dcd9-4e1e-868b-1af88726dd4e"}}}}, {"uuid": "f8606531-663e-47cf-8178-789276058169", "name": "6ab123dc-6c35-4df5-8209-24b8745916dd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6155541211188646, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3901757582026717, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7c78dccd-a904-40f6-aae0-535fd349386c", "name": "d096316e-5678-4fdc-96ea-49e7e048da3b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8606531-663e-47cf-8178-789276058169"}}}]}, {"uuid": "20f2b601-a6da-407d-9ddf-87c50e403dec", "name": "load_p1rlv87_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "46ee0e6c-daf7-4412-94a7-5332a6a97656"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7c78dccd-a904-40f6-aae0-535fd349386c"}}}}, {"uuid": "9b3e1397-1275-46d9-9b9a-44746c91dd20", "name": "258bad8c-9602-4318-9c3c-e2a3e4e2e011_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6155541211188646, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3901757582026717, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3b78c1ee-1cbb-4069-aec6-ee865c5810cf", "name": "fc6c0202-3e9d-4df9-840e-d229a3b85917", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9b3e1397-1275-46d9-9b9a-44746c91dd20"}}}]}, {"uuid": "3be5a22a-d467-4a98-a15c-ee8144f64ffa", "name": "load_p1rlv87_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "46ee0e6c-daf7-4412-94a7-5332a6a97656"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3b78c1ee-1cbb-4069-aec6-ee865c5810cf"}}}}, {"uuid": "98718c72-49ed-4f8b-94f4-4486786a2f17", "name": "8d2cd1f7-4c5f-4548-8f39-8c21701f2f80_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3439175585507637, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8866404836608991, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a834a5c7-98fd-4c36-a1a2-117df752ee7d", "name": "66056a6c-7515-44a0-8fe2-220d35df50b5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "98718c72-49ed-4f8b-94f4-4486786a2f17"}}}]}, {"uuid": "31a2910b-97f0-435f-8446-edb59ff49f20", "name": "load_p1rlv88_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "188047cd-3f14-4240-91fe-30113d48152b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a834a5c7-98fd-4c36-a1a2-117df752ee7d"}}}}, {"uuid": "2205e2f6-a33f-480b-871b-dff81b6dfe6f", "name": "74a63789-fa7d-45df-9e5f-00cf98af8d57_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3439175585507637, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8866404836608991, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "811f21d5-64e0-4d1f-aa87-f48fe0c030be", "name": "22c86dd0-3ef8-43a5-a22d-be5e7a8838b3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2205e2f6-a33f-480b-871b-dff81b6dfe6f"}}}]}, {"uuid": "13edc7c2-1815-4ec8-864b-37a1be4f09ed", "name": "load_p1rlv88_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "188047cd-3f14-4240-91fe-30113d48152b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "811f21d5-64e0-4d1f-aa87-f48fe0c030be"}}}}, {"uuid": "58590f5d-13ba-4b38-bd02-39cb9b23f78c", "name": "e9546252-1b58-4899-9c11-7318389954bc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.872515319591797, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7328111219910317, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "84b98861-33f5-4f04-a307-ce744f52b0a2", "name": "324e5a11-5970-42e7-b780-a2a7a153e909", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58590f5d-13ba-4b38-bd02-39cb9b23f78c"}}}]}, {"uuid": "9df16e4f-d791-4919-8ac9-6fa71869a7f6", "name": "load_p1rlv89_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24d75e9a-0249-48ca-ad10-32738bb6a519"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "84b98861-33f5-4f04-a307-ce744f52b0a2"}}}}, {"uuid": "4411040a-b8aa-4292-8c6f-6b01cd8a0937", "name": "0215f688-785c-42bb-9301-214b3f14d55b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.872515319591797, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7328111219910317, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d71ed8bc-50f6-4a34-bd20-821b33cb7331", "name": "d6b371e7-a88d-4ac8-90bc-da731158d936", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4411040a-b8aa-4292-8c6f-6b01cd8a0937"}}}]}, {"uuid": "68f4c66d-4cd7-49d8-bf03-0e936b39cc47", "name": "load_p1rlv89_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24d75e9a-0249-48ca-ad10-32738bb6a519"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d71ed8bc-50f6-4a34-bd20-821b33cb7331"}}}}, {"uuid": "f0818f91-427a-4dac-859a-9db5b784179b", "name": "606a83fe-20ef-45bd-92c5-f5146a296b44_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6767459289154356, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5300288174067083, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4e5f0c53-8b54-448d-a458-e7d628e7e647", "name": "7d1c415d-e8dc-4012-ba79-b478fef95e10", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f0818f91-427a-4dac-859a-9db5b784179b"}}}]}, {"uuid": "2938636d-de76-44c7-8bae-5ca12ea547e5", "name": "load_p1rlv90_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e06b2ac7-926e-4caf-afac-386910d4ea5e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4e5f0c53-8b54-448d-a458-e7d628e7e647"}}}}, {"uuid": "737e66f7-4b97-4feb-9812-0697f1b837ea", "name": "98a76c71-fc18-4ba7-aaae-ffd2f60dbabf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6767459289154356, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5300288174067083, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "383a78a2-9fcc-402b-a8c8-d9401b3d9bc1", "name": "5bdef5f2-0868-4b5e-8d9b-45781ef23db4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "737e66f7-4b97-4feb-9812-0697f1b837ea"}}}]}, {"uuid": "4e1fefc7-4df0-49fd-9047-d74b8256fd10", "name": "load_p1rlv90_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e06b2ac7-926e-4caf-afac-386910d4ea5e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "383a78a2-9fcc-402b-a8c8-d9401b3d9bc1"}}}}, {"uuid": "18090cd0-1050-4ea4-9081-1b5987f13ed5", "name": "859d3065-e984-44a5-80da-e2ac323cea76_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.089287670026504, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22715368737478026, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dd1b2f42-bfb0-4733-be1f-244a6f9aff0f", "name": "904dc742-32db-4a73-a9b3-ec2156ab46bf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "18090cd0-1050-4ea4-9081-1b5987f13ed5"}}}]}, {"uuid": "99780ee0-abf9-4307-b4e4-ed14d98ebf73", "name": "load_p1rlv91_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a1f01bc-d1f1-4d92-b1e2-1f8223624c52"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dd1b2f42-bfb0-4733-be1f-244a6f9aff0f"}}}}, {"uuid": "fb746a89-e5d8-407e-983a-f03e98d40634", "name": "b0033884-40dc-422f-a2ca-e44dfe1edc9f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.089287670026504, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22715368737478026, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "29c942c6-c2bb-4192-9690-6d377bdf7fa1", "name": "43d21665-1ce2-4376-aa4a-c9603e1290cd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fb746a89-e5d8-407e-983a-f03e98d40634"}}}]}, {"uuid": "9f5996d0-70d0-46af-a97f-981b46824f37", "name": "load_p1rlv91_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a1f01bc-d1f1-4d92-b1e2-1f8223624c52"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "29c942c6-c2bb-4192-9690-6d377bdf7fa1"}}}}, {"uuid": "fe1ba8b5-2e95-43ff-a991-580ba9a4d8e8", "name": "6159d973-f677-4323-8366-eed9b570ef52_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.298373512871933, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.08780226018253445, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6ddbae49-7bba-48e9-b129-7c86cceadc16", "name": "4afa950b-0abb-4e3f-8041-4d9ee05e086c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fe1ba8b5-2e95-43ff-a991-580ba9a4d8e8"}}}]}, {"uuid": "6e7fa03a-2160-4bc3-9a4f-cc003402162c", "name": "load_p1rlv92_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db8f484a-94d5-4d20-8ebf-6708b1601a0d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6ddbae49-7bba-48e9-b129-7c86cceadc16"}}}}, {"uuid": "f8b727ed-1984-40fc-9771-1efd1d55309f", "name": "bd82d5a0-503b-4b3c-b694-64730b273252_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.298373512871933, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.08780226018253445, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5bd4562a-8138-450e-a625-2848c9a1501a", "name": "75349981-2801-4269-9d4f-7e93fd11a841", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8b727ed-1984-40fc-9771-1efd1d55309f"}}}]}, {"uuid": "614d03f1-10f5-420d-b6f1-ae9627c6077f", "name": "load_p1rlv92_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db8f484a-94d5-4d20-8ebf-6708b1601a0d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5bd4562a-8138-450e-a625-2848c9a1501a"}}}}, {"uuid": "acc5f822-9896-4ed6-b7f9-961c04a79fcf", "name": "2d5e9b56-2043-4d51-b09f-0eae337cba7c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1206689642843692, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34257205075767067, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a5557f1-421f-4b7b-928f-124c33d795b9", "name": "3c2684f6-00a4-4532-85da-7a965986254c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "acc5f822-9896-4ed6-b7f9-961c04a79fcf"}}}]}, {"uuid": "c54cefdf-63d6-4bcf-bfae-bcfa3a804ce2", "name": "load_p1rlv93_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0060c029-188f-4725-a935-8d0d9cc892f7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a5557f1-421f-4b7b-928f-124c33d795b9"}}}}, {"uuid": "c677df67-d23d-4c53-a4ad-da31ba873674", "name": "f61f8ad5-a993-4e20-be49-6f3094aae04a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1206689642843692, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34257205075767067, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ae9693df-240a-4ac1-ac44-1fa9ec0c4ac9", "name": "e82986f7-3cd6-4361-b8cd-9dcceedd0c16", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c677df67-d23d-4c53-a4ad-da31ba873674"}}}]}, {"uuid": "cba07de9-9ed8-4aaf-915f-356b567f28e9", "name": "load_p1rlv93_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0060c029-188f-4725-a935-8d0d9cc892f7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ae9693df-240a-4ac1-ac44-1fa9ec0c4ac9"}}}}, {"uuid": "f5710e93-0e63-4dda-8322-b339e9baffcc", "name": "a60b88aa-9ce2-438b-acfd-d3a51a091e64_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.365256087534968, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9406994095530364, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d3515b45-b2cd-4e6d-82dc-9d0d1fcf1ff6", "name": "90eba57b-5b28-40a8-8df5-43435c8b0322", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f5710e93-0e63-4dda-8322-b339e9baffcc"}}}]}, {"uuid": "81751aa3-7248-4487-bbb0-b75319417ef3", "name": "load_p1rlv94_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db2d4080-1f43-47a3-9f3a-e25d1e4f5076"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d3515b45-b2cd-4e6d-82dc-9d0d1fcf1ff6"}}}}, {"uuid": "2bcf0af3-f731-4831-b95e-ab9b2c537f24", "name": "4511a972-ce32-4d4c-9040-93b763ddb4f0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.365256087534968, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9406994095530364, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6746918e-c2fb-499a-a5de-c0c2e352830c", "name": "dacd287d-7ee9-4588-a9d7-cc997c4f5b54", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2bcf0af3-f731-4831-b95e-ab9b2c537f24"}}}]}, {"uuid": "3da52a7f-22d5-4c46-9943-4acb1cf2e86d", "name": "load_p1rlv94_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db2d4080-1f43-47a3-9f3a-e25d1e4f5076"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6746918e-c2fb-499a-a5de-c0c2e352830c"}}}}, {"uuid": "9da11bbe-1bb9-4cbe-aaea-cba496a39b01", "name": "7b735d2a-834d-4e2a-bdd2-b01ed3d8ad3d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2874196130666418, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9219654181970236, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "99b4f378-964b-4383-ad8c-0846925d399a", "name": "0c9ff4eb-c022-4e78-8ab2-7bb6a0a5d5b5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9da11bbe-1bb9-4cbe-aaea-cba496a39b01"}}}]}, {"uuid": "7403fe65-1672-4aa6-bd34-9eec32802b07", "name": "load_p1rlv96_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31508077-f731-47cb-94a9-869d7910e406"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "99b4f378-964b-4383-ad8c-0846925d399a"}}}}, {"uuid": "d2b635de-b7b8-4569-9d7e-06f777a219b5", "name": "4a173121-e8c8-4e35-b054-6f8ceb91a0ae_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2874196130666418, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9219654181970236, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e36bcef7-5406-4902-b65c-0dccf635ba6c", "name": "e39255b9-2c3d-4945-acad-e7ab0a898bea", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d2b635de-b7b8-4569-9d7e-06f777a219b5"}}}]}, {"uuid": "07546d73-cdde-49cf-9284-ed9c72056d08", "name": "load_p1rlv96_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31508077-f731-47cb-94a9-869d7910e406"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e36bcef7-5406-4902-b65c-0dccf635ba6c"}}}}, {"uuid": "c16641aa-8d69-474e-83f8-c5385964d545", "name": "04e55605-b003-4b7c-9d1e-ca79dd286853_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.297832728168154, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6109723215697453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c423ba8b-348a-4c26-81c6-ccd5725736f5", "name": "eaeca3f8-e3de-487d-8694-519965bca661", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c16641aa-8d69-474e-83f8-c5385964d545"}}}]}, {"uuid": "ff0f1762-f691-4ce5-ab27-622a05e5025f", "name": "load_p1rlv98_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "82f19d5c-0941-411d-8baa-3ba029471dae"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c423ba8b-348a-4c26-81c6-ccd5725736f5"}}}}, {"uuid": "bf1c9d20-3c94-45dd-b6cd-2ce537df9f0a", "name": "671e29c0-a4f8-4e6f-8a68-960733b787f0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.297832728168154, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6109723215697453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bc14a11d-391f-4b84-8e60-875d7f8679d5", "name": "9fb52573-f6d7-4fcf-925f-e50b3885a9c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bf1c9d20-3c94-45dd-b6cd-2ce537df9f0a"}}}]}, {"uuid": "7905d68d-503b-472c-967a-7778a52f0994", "name": "load_p1rlv98_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "82f19d5c-0941-411d-8baa-3ba029471dae"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bc14a11d-391f-4b84-8e60-875d7f8679d5"}}}}, {"uuid": "7e69ce24-4795-4dbb-b16c-ef9fa0af989d", "name": "6117d5a6-e73f-4b72-89d1-9c9623c39420_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5294251690866196, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6012221542672356, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c78366f5-22c9-4231-a55e-c5b776304b75", "name": "8c7efc8e-047f-4943-afc9-6ddbb1c58202", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7e69ce24-4795-4dbb-b16c-ef9fa0af989d"}}}]}, {"uuid": "e8df70c9-8f8f-4739-abab-34b80d2a23b0", "name": "load_p1rlv99_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc4a448a-c6cb-4714-b8e6-b75bc6bc219c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c78366f5-22c9-4231-a55e-c5b776304b75"}}}}, {"uuid": "c56ce2ea-ddf1-4f61-bb61-b570626f985a", "name": "202db26d-789c-46af-9ccb-e957aec15c92_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5294251690866196, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6012221542672356, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e5fa98dd-17e0-4883-a85e-6066e6729a98", "name": "fdfadd89-1aab-4f45-9ca4-33d1a298628e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c56ce2ea-ddf1-4f61-bb61-b570626f985a"}}}]}, {"uuid": "cd4a408f-1a33-428f-8101-bed597fcb8c3", "name": "load_p1rlv99_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc4a448a-c6cb-4714-b8e6-b75bc6bc219c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e5fa98dd-17e0-4883-a85e-6066e6729a98"}}}}, {"uuid": "184da65b-8dc6-4ca7-8329-4e9be7d55810", "name": "e1145f98-92e2-4c52-a121-c70a893fee4f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.779437116944347, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0510023138100544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "abf9b856-24e3-43b0-993e-941a700e5987", "name": "c4030a1e-6309-4395-954e-04d3068913d1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "184da65b-8dc6-4ca7-8329-4e9be7d55810"}}}]}, {"uuid": "f15e6046-885a-43de-bd29-9aab72b45f9a", "name": "load_p1rlv100_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62a0d673-eaba-4032-9038-8095e2d53999"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "abf9b856-24e3-43b0-993e-941a700e5987"}}}}, {"uuid": "cfd38289-4519-4c78-9e88-aa9280b90980", "name": "75c824d7-7ace-4c79-ad40-933f5f7e2c5e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.779437116944347, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0510023138100544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "04280e76-fa83-4fed-9f67-b16b1e5b6b49", "name": "3a94513d-40ef-46e5-b7ea-92d4868cf199", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cfd38289-4519-4c78-9e88-aa9280b90980"}}}]}, {"uuid": "215191e3-9ef4-4b21-b313-d2806787197c", "name": "load_p1rlv100_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62a0d673-eaba-4032-9038-8095e2d53999"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "04280e76-fa83-4fed-9f67-b16b1e5b6b49"}}}}, {"uuid": "5b4e2d80-8248-4202-a3e8-45a7ae4710f9", "name": "8247a08c-fdb0-411b-8148-73efe847f6ce_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.684904254134122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42635901069761617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "041fd195-9980-4855-8874-8c010832cf81", "name": "0f69f44e-235d-4ce5-9212-23afb844695f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b4e2d80-8248-4202-a3e8-45a7ae4710f9"}}}]}, {"uuid": "3ee2b65f-9dd7-4934-8212-cd6ef1a27825", "name": "load_p1rlv101_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48d1be49-5aca-4e18-8b85-2a1274b3f26d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "041fd195-9980-4855-8874-8c010832cf81"}}}}, {"uuid": "06baf80c-e581-4a2d-8094-32f6084c37d2", "name": "28e8fd55-991f-4d03-a67c-f331858403d8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.684904254134122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42635901069761617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bf9a217b-e25f-4108-8a18-7d0780f3baab", "name": "e6385cf4-58b6-4786-a1b8-c7b9f35d2275", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "06baf80c-e581-4a2d-8094-32f6084c37d2"}}}]}, {"uuid": "9824b145-a3bb-4887-bf47-ca9d0d0e83ed", "name": "load_p1rlv101_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48d1be49-5aca-4e18-8b85-2a1274b3f26d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bf9a217b-e25f-4108-8a18-7d0780f3baab"}}}}, {"uuid": "235cb1eb-79de-4ad0-8c13-d63c4b99b76d", "name": "deb4cd16-3566-4648-9436-d95d86e4dbd4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3841896439528762, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.62886585412856, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8621e40e-4298-42dc-804a-4591b2e0be9c", "name": "4ab2e48e-e6e1-4262-8492-5932347eb446", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "235cb1eb-79de-4ad0-8c13-d63c4b99b76d"}}}]}, {"uuid": "ae29ac6d-f514-4368-abfe-21c408a60c50", "name": "load_p1rlv102_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06a432e3-dd37-4c52-b954-6652bb529c8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8621e40e-4298-42dc-804a-4591b2e0be9c"}}}}, {"uuid": "1d62996a-acb8-4e7a-a168-70dff02adce8", "name": "eeed8d1d-bef3-4c78-a573-cfe779410549_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3841896439528762, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.62886585412856, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ab2839d8-b9ee-435e-bddd-23a2cc6eb79b", "name": "cda44325-54f8-43ee-ba3b-8a801e25efc0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1d62996a-acb8-4e7a-a168-70dff02adce8"}}}]}, {"uuid": "328b551e-2c99-47e8-94d6-1e6d8062cb39", "name": "load_p1rlv102_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06a432e3-dd37-4c52-b954-6652bb529c8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ab2839d8-b9ee-435e-bddd-23a2cc6eb79b"}}}}, {"uuid": "148e865f-b291-44ae-b89a-29810ad5eaa7", "name": "967f2b60-182a-4b89-968b-14af128f040a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2440101223346245, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10648703060010346, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b829b28a-b328-4762-aca6-6fa9fe5838a9", "name": "b40fd67d-119e-4af8-a80c-6f4c065633f9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "148e865f-b291-44ae-b89a-29810ad5eaa7"}}}]}, {"uuid": "fdd5293f-73d1-4c96-8bfc-9c3a25fc0331", "name": "load_p1rlv103_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85afc796-3fe5-4027-b84e-10d502124636"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b829b28a-b328-4762-aca6-6fa9fe5838a9"}}}}, {"uuid": "b0bedc38-f5ec-4329-986f-8320ea45375f", "name": "0640dbbc-4f29-42ba-a44f-a9bafca5c79b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2440101223346245, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10648703060010346, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "368d54dd-4d93-4beb-8956-ab1d59f80508", "name": "b93ea6cb-86f8-4177-be13-5264cefa5c3e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b0bedc38-f5ec-4329-986f-8320ea45375f"}}}]}, {"uuid": "e8f19935-fdb6-422c-a4ea-650290277367", "name": "load_p1rlv103_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85afc796-3fe5-4027-b84e-10d502124636"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "368d54dd-4d93-4beb-8956-ab1d59f80508"}}}}, {"uuid": "aea1ad96-2ffc-46ed-b4b6-62581ccf1126", "name": "2843f780-0c39-4f88-9e82-8a49607d6a80_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.651721747239447, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.750976002130125, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ba45d071-0691-4fb5-a0fa-d9fbb2f0a8f1", "name": "7344c816-a488-4607-869f-eca427b482d9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aea1ad96-2ffc-46ed-b4b6-62581ccf1126"}}}]}, {"uuid": "0f430a54-77f8-46b6-bbc2-0a0f6f19955f", "name": "load_p1rlv104_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c76c5b8f-1994-470c-a024-b97c73b9bb41"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ba45d071-0691-4fb5-a0fa-d9fbb2f0a8f1"}}}}, {"uuid": "79e38f7e-8b83-4854-b01a-4431739ddef2", "name": "eeefaf38-2a4e-4ed2-a228-202d34333004_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.651721747239447, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.750976002130125, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d960e788-92fb-47d2-8fca-56b2768f1a29", "name": "b7563fdf-9304-4cbf-b1bc-ee9f9adad567", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "79e38f7e-8b83-4854-b01a-4431739ddef2"}}}]}, {"uuid": "bd4d9be8-ecf0-4c23-82f2-e58b4760da60", "name": "load_p1rlv104_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c76c5b8f-1994-470c-a024-b97c73b9bb41"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d960e788-92fb-47d2-8fca-56b2768f1a29"}}}}, {"uuid": "2e8536ec-1a2e-4e27-85a8-b467888ca835", "name": "13b2f988-564c-443c-baad-c2eb203cf2aa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c1ec30df-0bdb-4026-9bc4-a04b856b74e9", "name": "140b9b1c-e959-4ce0-bffa-25f4579b2333", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2e8536ec-1a2e-4e27-85a8-b467888ca835"}}}]}, {"uuid": "d8bfa8fc-8fbd-4255-90e5-e27ccaaa2648", "name": "load_p1rlv105_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fe82ede-430d-454d-b9d0-e212d0621ea1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c1ec30df-0bdb-4026-9bc4-a04b856b74e9"}}}}, {"uuid": "f8007fef-a4cb-415b-a99b-a5914e404d70", "name": "7684eece-222c-4a8a-92f3-bc8020f4d912_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3105f80b-d304-4233-a025-1f6c2ecd50d3", "name": "4f238f30-c677-4975-a961-050e8ea1bed9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8007fef-a4cb-415b-a99b-a5914e404d70"}}}]}, {"uuid": "578f8926-bd9e-4b24-a882-5acb77252820", "name": "load_p1rlv105_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fe82ede-430d-454d-b9d0-e212d0621ea1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3105f80b-d304-4233-a025-1f6c2ecd50d3"}}}}, {"uuid": "14fae872-1b77-45ce-add0-e7976b3630fd", "name": "ed854caa-4326-4a77-93b2-0b14fe09ff85_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.30121669259111117, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.11773911124465561, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9b677954-9657-4c65-ba63-087dba6ab1bb", "name": "f6bc12e0-cfc4-4bc2-b323-86d2ea685920", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "14fae872-1b77-45ce-add0-e7976b3630fd"}}}]}, {"uuid": "f6200b6c-6b46-41fb-b3c5-1862a8054e9d", "name": "load_p1rlv107_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "096e92a6-ea34-435e-a059-57d5234e1654"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9b677954-9657-4c65-ba63-087dba6ab1bb"}}}}, {"uuid": "8ae42569-ca98-43cd-a5f8-37969e71c278", "name": "5691c38e-10b3-48f2-bf5a-2fe899952497_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.30121669259111117, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.11773911124465561, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3c6b4294-6bed-4537-9fa8-ee36816240ed", "name": "63298650-1925-432c-800a-ed81441ae492", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ae42569-ca98-43cd-a5f8-37969e71c278"}}}]}, {"uuid": "ffaf6895-8364-48e3-8054-1985456b2eab", "name": "load_p1rlv107_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "096e92a6-ea34-435e-a059-57d5234e1654"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3c6b4294-6bed-4537-9fa8-ee36816240ed"}}}}, {"uuid": "c35b2abf-c50e-4d68-ad3d-9ae50af82d54", "name": "d0ef8001-1275-4a80-a82a-0af9540d10b9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.522559572152904, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23989402539717328, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e88bd1c6-bc36-40cd-b0c1-7c15933cc79f", "name": "e42ef0cb-6e24-4453-a4b7-866902a90c1e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c35b2abf-c50e-4d68-ad3d-9ae50af82d54"}}}]}, {"uuid": "069c0311-57f5-4fb5-9df1-29924928c296", "name": "load_p1rlv108_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "afc70b80-ab76-440c-b05b-149458051675"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e88bd1c6-bc36-40cd-b0c1-7c15933cc79f"}}}}, {"uuid": "71b788fb-ce89-48a2-aceb-69953c603aab", "name": "79c06ebe-683b-49e5-ad12-61270762b53d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.522559572152904, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23989402539717328, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cf8a5e2f-b19e-41a5-8bff-338e32c1e09c", "name": "fa4c6444-08bd-47a2-97ed-04ada0ff6b1e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "71b788fb-ce89-48a2-aceb-69953c603aab"}}}]}, {"uuid": "3fd99e63-6ab6-44a5-b868-531cf263e5f9", "name": "load_p1rlv108_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "afc70b80-ab76-440c-b05b-149458051675"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cf8a5e2f-b19e-41a5-8bff-338e32c1e09c"}}}}, {"uuid": "8f1d6e19-6d64-4f97-855a-c6626c5778af", "name": "b3e647d6-daaa-422c-871a-4016fbbdddf6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5369480608064634, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2969034126636569, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "516685fd-7351-4510-9728-85aacad9a207", "name": "55c7787a-4d3a-4737-a3a5-8165bcc1d472", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8f1d6e19-6d64-4f97-855a-c6626c5778af"}}}]}, {"uuid": "054abb3b-f1d6-4857-817d-e614797894a3", "name": "load_p1rlv109_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c76fc99c-c160-4ed0-85dd-ec3da962bb24"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "516685fd-7351-4510-9728-85aacad9a207"}}}}, {"uuid": "d62c79c8-4ebc-4d85-9274-1a052f286007", "name": "5ba0d181-1f41-4828-9153-763fc26a1566_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5369480608064634, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2969034126636569, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c979a193-0990-4901-a9ce-244a39c8b763", "name": "ae7c6d8c-3bfe-4e99-8b38-53f7bc6eef9e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d62c79c8-4ebc-4d85-9274-1a052f286007"}}}]}, {"uuid": "1650bce1-bb01-4df4-84aa-eea243ec7930", "name": "load_p1rlv109_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c76fc99c-c160-4ed0-85dd-ec3da962bb24"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c979a193-0990-4901-a9ce-244a39c8b763"}}}}, {"uuid": "24517943-5fde-4054-a339-befca697a048", "name": "4a5ecdab-80cf-4c43-aa11-c20c7ec88038_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4292209363155218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1643515800752328, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f171827b-d16c-4336-9893-c9d50b9e59e0", "name": "b14c8827-88b8-436f-9b1f-b3b1d850c4cf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "24517943-5fde-4054-a339-befca697a048"}}}]}, {"uuid": "d765a2ab-2053-435f-8de7-4c64abc39b0e", "name": "load_p1rlv111_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66748ae6-b6ef-4228-bb0f-f9a121f0e1a3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f171827b-d16c-4336-9893-c9d50b9e59e0"}}}}, {"uuid": "5b0e7b80-45b2-493b-8d9c-424d3d62917b", "name": "d450675c-b18c-41b0-a158-ea2f17f93e06_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4292209363155218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1643515800752328, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f5ab6d2-eb37-49ce-b90a-6435b99c77cd", "name": "3502e7b3-7a68-4ce9-8819-f7679319c5e4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b0e7b80-45b2-493b-8d9c-424d3d62917b"}}}]}, {"uuid": "072461f1-614b-4520-9bef-105e7407bd14", "name": "load_p1rlv111_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66748ae6-b6ef-4228-bb0f-f9a121f0e1a3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f5ab6d2-eb37-49ce-b90a-6435b99c77cd"}}}}, {"uuid": "a129d215-5479-4777-9afd-005fee86592b", "name": "35399736-e507-42af-9286-645d637ea53c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.554325896527151, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5828877012431191, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2ea15295-5d76-48a2-ad39-163db0210208", "name": "b60cd738-ea7d-451b-9fd2-10a38368b834", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a129d215-5479-4777-9afd-005fee86592b"}}}]}, {"uuid": "d37897bf-4995-482d-afae-238a3e5a4765", "name": "load_p1rlv112_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25edc94b-a44b-4200-8cde-73941c2818b8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2ea15295-5d76-48a2-ad39-163db0210208"}}}}, {"uuid": "0ad87fe1-fd4e-495a-a783-359e0194239e", "name": "c665dc92-5a1c-489b-947b-d94f6473342b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.554325896527151, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5828877012431191, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5d7aca6c-9fb3-4efd-9124-b1b7c09671cc", "name": "c95acac6-e43d-4abf-96a7-26ee5bd498a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0ad87fe1-fd4e-495a-a783-359e0194239e"}}}]}, {"uuid": "52b08107-3aaf-466d-aaa2-91607658bc6a", "name": "load_p1rlv112_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25edc94b-a44b-4200-8cde-73941c2818b8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5d7aca6c-9fb3-4efd-9124-b1b7c09671cc"}}}}, {"uuid": "f55f35ca-f906-479e-ada5-5b15d640dd78", "name": "0391e0ae-e8b6-4758-af68-2b1e73941310_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0288569450045768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2608148575838028, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5d05da5e-7c57-4473-894a-9cbd25435b09", "name": "ec30e385-acc1-45b8-ad4f-a7e08a1a93d0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f55f35ca-f906-479e-ada5-5b15d640dd78"}}}]}, {"uuid": "e5606f88-9627-4fde-819e-6a380b5a979b", "name": "load_p1rlv113_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2756378a-0c67-47cf-969d-bdb9e55c8a4b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5d05da5e-7c57-4473-894a-9cbd25435b09"}}}}, {"uuid": "35a42fc6-3d27-405c-b689-6461c37d0bf0", "name": "2e8e1a08-4c19-4975-a423-2bf62e7d8243_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0288569450045768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2608148575838028, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "663fbd3f-6296-4deb-8d4b-239d3aedb205", "name": "b241c0d4-30a7-46eb-bbf8-ae3c01cdc319", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "35a42fc6-3d27-405c-b689-6461c37d0bf0"}}}]}, {"uuid": "42b5dc58-5ed3-42bb-a34e-9f6785057db3", "name": "load_p1rlv113_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2756378a-0c67-47cf-969d-bdb9e55c8a4b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "663fbd3f-6296-4deb-8d4b-239d3aedb205"}}}}, {"uuid": "ee0e5033-82a3-4694-bbb8-33ad3d267e04", "name": "a7547c44-ed9f-4704-a038-b3fbd10d21a0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7419011483459746, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17632142927590772, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c8eeb9e6-96c3-4a2b-bc38-71d012f39165", "name": "50f3db76-64cf-4e1b-a57e-c7172cc3fa46", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ee0e5033-82a3-4694-bbb8-33ad3d267e04"}}}]}, {"uuid": "a14b9591-bce8-4a3f-9c90-e1f4b8a6954b", "name": "load_p1rlv114_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7934cd3-dcd6-4b67-8206-8a3636b6f75d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c8eeb9e6-96c3-4a2b-bc38-71d012f39165"}}}}, {"uuid": "9f118354-5ba0-4d57-b544-d315fa665779", "name": "197f306d-8b59-49a8-b384-bec24c9297a5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7419011483459746, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17632142927590772, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "97559216-4f7a-4506-b67e-9278e3f53e4c", "name": "5b8e997f-2eae-4714-9dc7-c452c92d4a90", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9f118354-5ba0-4d57-b544-d315fa665779"}}}]}, {"uuid": "9d62d752-2c7b-4ee0-8f15-1839d9751b31", "name": "load_p1rlv114_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7934cd3-dcd6-4b67-8206-8a3636b6f75d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "97559216-4f7a-4506-b67e-9278e3f53e4c"}}}}, {"uuid": "b6fd0128-bc95-4086-9e43-7c8ccf220076", "name": "5cd4b925-275d-4ca5-b7bd-64fda137a71d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.883515343353138, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18989418857380705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "878e8f33-af62-487e-9af6-6d0c498d84c8", "name": "8e522171-e97f-471d-8866-b02f7a5f77d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b6fd0128-bc95-4086-9e43-7c8ccf220076"}}}]}, {"uuid": "57839523-1c75-459f-a365-3cd8fbb9fde7", "name": "load_p1rlv115_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "919a48e8-b378-4dd5-8e33-a2602fb58bc0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "878e8f33-af62-487e-9af6-6d0c498d84c8"}}}}, {"uuid": "862cf827-2fa0-4e3a-9d53-d3de3cfff5ee", "name": "1b7f0e82-7b47-4d9b-ac23-d5091debc8bf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.883515343353138, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.18989418857380705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1ff35b48-6c02-4af4-943b-a9c4140b8678", "name": "9b5134e1-42e0-4eee-a0b1-f27c6d61ab86", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "862cf827-2fa0-4e3a-9d53-d3de3cfff5ee"}}}]}, {"uuid": "a5b6fcd7-3c22-4997-bb4a-90ad17d41503", "name": "load_p1rlv115_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "919a48e8-b378-4dd5-8e33-a2602fb58bc0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1ff35b48-6c02-4af4-943b-a9c4140b8678"}}}}, {"uuid": "23f0b4e3-06ad-46a0-8acb-16543172da24", "name": "19b07006-31d9-4290-bbb7-26a3a12507fd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7362273540893955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24527287728713068, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e1548353-7017-48de-a9e3-439c9a0bba57", "name": "85aa85ca-0027-4da8-b581-95318cc8a814", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "23f0b4e3-06ad-46a0-8acb-16543172da24"}}}]}, {"uuid": "b5abfb5c-782d-4495-9bd1-e78f868ffb9d", "name": "load_p1rlv117_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e6de569-7f61-439e-a402-850c4f071ab3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e1548353-7017-48de-a9e3-439c9a0bba57"}}}}, {"uuid": "53447ca1-e6c3-4a00-9395-443683755039", "name": "a1db1749-39b2-4dc5-9bb5-b31dca0be6c1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7362273540893955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24527287728713068, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2d59efa9-d691-4ccc-b6a5-27c0fc8f2426", "name": "2f4bafcf-2bc3-4dcc-86e1-1a9567cbaf83", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "53447ca1-e6c3-4a00-9395-443683755039"}}}]}, {"uuid": "80f37d62-ee74-4124-a567-ee5a167a8543", "name": "load_p1rlv117_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e6de569-7f61-439e-a402-850c4f071ab3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2d59efa9-d691-4ccc-b6a5-27c0fc8f2426"}}}}, {"uuid": "e2e4aab7-cf99-48e7-8453-2f94b42aff45", "name": "806914aa-76f2-4988-b1d7-30aca0006156_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.074192704000552, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.129078804753558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "59d83935-cfff-4b37-9176-83da5cd721ff", "name": "98dea8e0-46fc-4d34-bf83-c423a96b79c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e2e4aab7-cf99-48e7-8453-2f94b42aff45"}}}]}, {"uuid": "4e09f639-e11f-4eab-89f1-fafcd4d8cb28", "name": "load_p1rlv118_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "247e37b3-d6d0-41d7-a6b3-ee29d415da50"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "59d83935-cfff-4b37-9176-83da5cd721ff"}}}}, {"uuid": "84bb5902-a714-4e27-aa5d-9b93b75ab90a", "name": "d3b07c70-907f-49c6-b00f-8af495f1e472_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.074192704000552, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.129078804753558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e8ec978d-abb5-4c1a-9abc-40e33eaad1f7", "name": "cefc2605-e448-422f-b93b-4c11333bf9fd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "84bb5902-a714-4e27-aa5d-9b93b75ab90a"}}}]}, {"uuid": "72198056-05f5-4903-8c74-c691d4a32759", "name": "load_p1rlv118_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "247e37b3-d6d0-41d7-a6b3-ee29d415da50"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e8ec978d-abb5-4c1a-9abc-40e33eaad1f7"}}}}, {"uuid": "719a89dd-b219-461d-81df-9f94b751432c", "name": "72182001-19d6-49c5-900d-f269aff2bea9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9571923411347831, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7946531538551662, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "59b30b42-f074-4170-92eb-b8bca83fa949", "name": "9bf0adc2-c199-423c-9395-851dadee10ea", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "719a89dd-b219-461d-81df-9f94b751432c"}}}]}, {"uuid": "33eaf0d1-0bf8-44c0-b0e5-452a215c3cb7", "name": "load_p1rlv119_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee33d90b-2f70-4c9d-863d-6486b95280b8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "59b30b42-f074-4170-92eb-b8bca83fa949"}}}}, {"uuid": "a8d19fde-9e9f-4fbf-8126-909580c17469", "name": "4e0c6550-e775-46e3-9879-acb13d1bdc30_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9571923411347831, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7946531538551662, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "583f5ac1-4c54-4883-8660-c250b7e3cb04", "name": "33bc3b30-57e1-46aa-bc52-31df7304976a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a8d19fde-9e9f-4fbf-8126-909580c17469"}}}]}, {"uuid": "cfe435c8-1fe6-4078-bdb4-a7d971412db5", "name": "load_p1rlv119_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee33d90b-2f70-4c9d-863d-6486b95280b8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "583f5ac1-4c54-4883-8660-c250b7e3cb04"}}}}, {"uuid": "27bf5446-2162-4885-b371-253ccb53de9b", "name": "f8adb0fa-f9c1-493e-b521-27f42c67975b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.297832728168154, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6109723215697453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4611dda0-db86-4242-915a-95dba9b96f8d", "name": "b7856dc6-74d1-4807-a9ee-fc7deb551e87", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "27bf5446-2162-4885-b371-253ccb53de9b"}}}]}, {"uuid": "82a70d6b-169a-4b40-8005-32e139b77ad0", "name": "load_p1rlv120_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a02925cd-7c5b-475f-9e91-30d639bb3c33"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4611dda0-db86-4242-915a-95dba9b96f8d"}}}}, {"uuid": "fad7872b-c335-45bc-aa98-e49b2eca9feb", "name": "ab1c6fed-c9bf-41cb-9a4b-bedce3492fb6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.297832728168154, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6109723215697453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b8fd66d8-f1ee-4917-b670-e9270f82689d", "name": "8566d8fa-2057-401d-860c-630f8ef812f8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fad7872b-c335-45bc-aa98-e49b2eca9feb"}}}]}, {"uuid": "7630ba82-773b-4559-9b9c-8880d22169e5", "name": "load_p1rlv120_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a02925cd-7c5b-475f-9e91-30d639bb3c33"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b8fd66d8-f1ee-4917-b670-e9270f82689d"}}}}, {"uuid": "13b895c5-18b1-4554-a332-4f8bdb4cb7e6", "name": "051a4bcc-e931-46ee-9d3c-808bd76a3c3f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.876043044068563, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8047319040687714, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e59e9b91-2be7-427f-8d2a-b439f06209a6", "name": "fada6878-7d42-49a2-807e-377e437143ff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "13b895c5-18b1-4554-a332-4f8bdb4cb7e6"}}}]}, {"uuid": "afb00e2d-1f8c-48e1-8edf-bb710714ed07", "name": "load_p1rlv121_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0dbaab50-3abc-4207-82dc-5fcc5be68aad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e59e9b91-2be7-427f-8d2a-b439f06209a6"}}}}, {"uuid": "a27d63eb-6dcd-40dc-8442-7c8671032d02", "name": "857e4ea9-3b0f-4208-9244-0af42af4a7e3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.876043044068563, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8047319040687714, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2718d551-8cf3-4600-9dc3-b4c3665e8a0e", "name": "33a47752-67d3-4b44-bde6-d9c114f75f21", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a27d63eb-6dcd-40dc-8442-7c8671032d02"}}}]}, {"uuid": "8ce1fecd-0c60-473b-869a-8a5bf9ff6166", "name": "load_p1rlv121_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0dbaab50-3abc-4207-82dc-5fcc5be68aad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2718d551-8cf3-4600-9dc3-b4c3665e8a0e"}}}}, {"uuid": "49b0e4ba-7ca3-4d34-af13-7e25824e6a76", "name": "1b47beed-07a2-45ae-b215-79e50838f478_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2437699409140923, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5571842941855458, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "84efaaec-d9f7-483f-9ab6-fc0a55a52f8c", "name": "7e10c91e-d599-4df1-a1fe-96851d0cf4a5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "49b0e4ba-7ca3-4d34-af13-7e25824e6a76"}}}]}, {"uuid": "e595319f-e5d3-498c-a031-e65dbe57223c", "name": "load_p1rlv122_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b02739e-d082-4c54-8deb-8ccc83ab82ab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "84efaaec-d9f7-483f-9ab6-fc0a55a52f8c"}}}}, {"uuid": "962e79fe-c222-4e40-9c9f-abbc2ce59cb0", "name": "067aa084-2c75-4d15-97aa-78b3e0b0a153_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2437699409140923, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5571842941855458, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7fa14ede-ebce-495f-9e9f-41b61144d1ff", "name": "3ad50f32-b317-4906-82aa-07733944795c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "962e79fe-c222-4e40-9c9f-abbc2ce59cb0"}}}]}, {"uuid": "eeffb200-c11b-446a-a198-cb403bac7beb", "name": "load_p1rlv122_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b02739e-d082-4c54-8deb-8ccc83ab82ab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7fa14ede-ebce-495f-9e9f-41b61144d1ff"}}}}, {"uuid": "8baad36a-cd5c-4c30-adee-29e71781f3fd", "name": "0dfa85db-08dc-409e-970c-c904c5c307bf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9353742885016981, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3630006054680373, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3c97fce8-7ca0-4309-b2eb-511d255f7ca8", "name": "b2bdc887-8e68-4385-a40f-325bfc8eab82", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8baad36a-cd5c-4c30-adee-29e71781f3fd"}}}]}, {"uuid": "f81f35ba-48df-4e21-9762-47dd4726f97d", "name": "load_p1rlv123_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6184fe8d-ae60-426a-8c0c-a3cc56c5b67e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3c97fce8-7ca0-4309-b2eb-511d255f7ca8"}}}}, {"uuid": "78b81e4a-3d2f-426f-b57f-85fbb095427c", "name": "c66c5166-c614-43f0-b2ea-ec48f019e1a1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9353742885016981, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3630006054680373, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4f4521b7-d7f6-4ec4-acff-ed7bc763dae0", "name": "416a179a-0784-4248-a2eb-67f0088efceb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "78b81e4a-3d2f-426f-b57f-85fbb095427c"}}}]}, {"uuid": "7c31539f-f638-4d65-965a-9d3ea5776d58", "name": "load_p1rlv123_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6184fe8d-ae60-426a-8c0c-a3cc56c5b67e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4f4521b7-d7f6-4ec4-acff-ed7bc763dae0"}}}}, {"uuid": "b3b2c077-f49b-4ef2-a732-d105b0c18c23", "name": "564c20b2-c549-4e21-a5d2-8ad1ba2d061a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4794755457968312, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.46197673612457824, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0fd74c8f-5b7d-440d-ab7b-58c8362163a4", "name": "e570946e-a438-4421-bcc5-7d72ca2612b9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b3b2c077-f49b-4ef2-a732-d105b0c18c23"}}}]}, {"uuid": "686de60c-d247-410b-b7f5-5fcfa2b57dd2", "name": "load_p1rlv124_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e5ca78b-6151-4a35-8a04-1bab215f0f10"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0fd74c8f-5b7d-440d-ab7b-58c8362163a4"}}}}, {"uuid": "3fda8210-f058-400a-95f6-942ca84ae691", "name": "1ce44c52-127a-4e74-b8ef-551022d11d8e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4794755457968312, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.46197673612457824, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b1c9a482-b6ba-4487-9ea8-6c9b7b2aa794", "name": "6aee4861-997c-47f7-a71a-8e27165836d7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3fda8210-f058-400a-95f6-942ca84ae691"}}}]}, {"uuid": "ae132a9a-c8c1-4756-9475-eaee18f1b99a", "name": "load_p1rlv124_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e5ca78b-6151-4a35-8a04-1bab215f0f10"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b1c9a482-b6ba-4487-9ea8-6c9b7b2aa794"}}}}, {"uuid": "b612dfd9-e950-4218-9a85-4200a50d317b", "name": "d1a68747-d3aa-44a9-8aa7-2f4992abe586_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "93059b3a-00fa-44b9-9ad6-92cd637f51fe", "name": "53bd28d2-e9a5-4b07-8ae7-1ed70eb98476", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b612dfd9-e950-4218-9a85-4200a50d317b"}}}]}, {"uuid": "b1748623-6759-4b31-93a1-5bf78c59fb76", "name": "load_p1rlv125_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3367cc2-b096-4cfb-ae71-038eb9e06b46"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "93059b3a-00fa-44b9-9ad6-92cd637f51fe"}}}}, {"uuid": "4c023815-5ad6-4f31-95d2-146176a71953", "name": "fcc40596-9760-41d7-94ed-8f6f7cd31098_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4a3e0581-451c-4c23-a56f-cf3fe911cef8", "name": "fe993a5d-8671-43a7-8e67-9d9689673f1d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4c023815-5ad6-4f31-95d2-146176a71953"}}}]}, {"uuid": "37e8cddf-d42e-4ce9-885b-d33d9cfe3388", "name": "load_p1rlv125_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3367cc2-b096-4cfb-ae71-038eb9e06b46"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4a3e0581-451c-4c23-a56f-cf3fe911cef8"}}}}, {"uuid": "8d060410-1b28-4508-841f-1a239a00d098", "name": "bea2eb65-94f6-44d6-a077-5c7ecacd7036_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5229589832640044, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3359880712066463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e4521922-851e-47ab-bd82-4c196fade484", "name": "a34ea912-dd78-4e06-8965-d6a42c1c87db", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8d060410-1b28-4508-841f-1a239a00d098"}}}]}, {"uuid": "4ef7ff68-ddbb-4dc5-8c3a-fd7218a0591c", "name": "load_p1rlv127_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ae7b1fe-08c4-4848-867e-e2426a325a99"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e4521922-851e-47ab-bd82-4c196fade484"}}}}, {"uuid": "9d1fb586-95ba-4e57-889e-356da6c25cb4", "name": "c59cec42-74f7-4e00-b345-b23208a2b15f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5229589832640044, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3359880712066463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fee10c7c-3ab1-48aa-b412-8bd7d2573dce", "name": "9b24d381-d5f0-43e9-bb9c-fa7a959c0857", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9d1fb586-95ba-4e57-889e-356da6c25cb4"}}}]}, {"uuid": "ac210a2b-1851-4e76-816d-e4e7b4899f93", "name": "load_p1rlv127_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ae7b1fe-08c4-4848-867e-e2426a325a99"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fee10c7c-3ab1-48aa-b412-8bd7d2573dce"}}}}, {"uuid": "b2b15cde-b33b-4e37-b2cf-5316406072de", "name": "64283c63-b3dc-4aee-bf3c-cc0f8573e2f1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4040789998842194, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4565305929598704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "79f9cf11-c820-47a1-9b74-f7369ae38b9f", "name": "47ef9dc3-4340-4d69-b3a7-a480ff9a4e5b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b2b15cde-b33b-4e37-b2cf-5316406072de"}}}]}, {"uuid": "cec1091b-7501-4f4e-b710-95c483f07f5d", "name": "load_p1rlv128_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56bc8935-c658-424c-83d8-0d13bf8d292a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "79f9cf11-c820-47a1-9b74-f7369ae38b9f"}}}}, {"uuid": "f8773ad2-a5dd-4a15-9301-b781dc157354", "name": "ca7087ae-5b39-413c-a0fc-bee47dafc86e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4040789998842194, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4565305929598704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "732c4bbf-d4bf-4149-8316-f476c8c78a2d", "name": "06b6bbb7-9c54-4598-b096-9dc27b8102b1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8773ad2-a5dd-4a15-9301-b781dc157354"}}}]}, {"uuid": "f9ac8698-72e1-42bb-90f8-d43a78c28a3d", "name": "load_p1rlv128_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56bc8935-c658-424c-83d8-0d13bf8d292a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "732c4bbf-d4bf-4149-8316-f476c8c78a2d"}}}}, {"uuid": "eedc1026-34be-47de-a2e0-f3e6ea500bf1", "name": "6b5e0677-f402-49ad-b4ac-193d1f15bed2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7537427041030689, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.37349948863112625, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4574fab1-142f-4cb8-a0b1-dac68b4ab565", "name": "3c75864d-6bb4-4f6f-9f9b-72ae7985f0fd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eedc1026-34be-47de-a2e0-f3e6ea500bf1"}}}]}, {"uuid": "d7f4afb4-7503-4c66-8194-4661a71cb399", "name": "load_p1rlv129_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6c42586-4f46-45c6-910f-90fca771cfd2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4574fab1-142f-4cb8-a0b1-dac68b4ab565"}}}}, {"uuid": "24d808e0-a25d-41bc-8aaf-9990eccb7ab4", "name": "56088df8-55c7-4fdc-896a-5f04e6ccb015_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7537427041030689, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.37349948863112625, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f39fe77-3d73-48ab-92ba-9fb9f8622ce2", "name": "f250c745-893d-400e-85f3-dccb3b92119b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "24d808e0-a25d-41bc-8aaf-9990eccb7ab4"}}}]}, {"uuid": "d92713c4-e2f3-475e-80e6-43f4332b0f7c", "name": "load_p1rlv129_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6c42586-4f46-45c6-910f-90fca771cfd2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f39fe77-3d73-48ab-92ba-9fb9f8622ce2"}}}}, {"uuid": "7206e78c-dc01-4a88-87dc-92f12b81c5ed", "name": "85c77c54-09b7-4b11-99df-3d2d2fb35559_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.297832728168154, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6109723215697453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4a29d63e-dea1-442d-a272-760c694e029c", "name": "9222c3b6-9c12-463a-8ec0-a7a065b61a82", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7206e78c-dc01-4a88-87dc-92f12b81c5ed"}}}]}, {"uuid": "c0a5d83c-19a2-4bbe-b430-96cd86c3ec5d", "name": "load_p1rlv130_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5c96953-6710-4765-b5bd-4359e03e4c63"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4a29d63e-dea1-442d-a272-760c694e029c"}}}}, {"uuid": "79588cfd-8b16-4b36-a195-5326be554ce5", "name": "a1928b35-55c4-4a97-bb90-117bc2179089_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.297832728168154, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6109723215697453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "780efec7-3429-400e-826c-6f883f72604d", "name": "36491887-4033-4fee-a6d9-2f3cac618305", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "79588cfd-8b16-4b36-a195-5326be554ce5"}}}]}, {"uuid": "7e42a97a-9ca0-445f-89dc-e988ed19372b", "name": "load_p1rlv130_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5c96953-6710-4765-b5bd-4359e03e4c63"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "780efec7-3429-400e-826c-6f883f72604d"}}}}, {"uuid": "9b2700f3-4011-4344-bdf5-7dc7f7441c55", "name": "3e5929fc-8438-437c-8433-c5f322bc79ba_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3885774782241163, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12624891415512582, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "390771cc-dc65-47c4-8419-4787ae8f5e54", "name": "b665265e-dc12-4058-8a80-9a4aaf2a8bcf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9b2700f3-4011-4344-bdf5-7dc7f7441c55"}}}]}, {"uuid": "5413e231-368b-4a65-8ed8-a723bdf8923d", "name": "load_p1rlv131_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "499fb461-ccb6-436a-8078-eec9beffb4a9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "390771cc-dc65-47c4-8419-4787ae8f5e54"}}}}, {"uuid": "c4778803-e672-41a7-94e1-30a30aa54414", "name": "343e43df-a998-42a9-a472-71fac05ed739_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3885774782241163, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12624891415512582, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1822e842-8251-466f-b5a8-9dfbd1cf9d26", "name": "747b0fbe-bcf2-4d83-b894-a7ebfa1d1448", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c4778803-e672-41a7-94e1-30a30aa54414"}}}]}, {"uuid": "3a3aa4b8-ceae-4213-a03e-7a8dc52d0961", "name": "load_p1rlv131_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "499fb461-ccb6-436a-8078-eec9beffb4a9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1822e842-8251-466f-b5a8-9dfbd1cf9d26"}}}}, {"uuid": "39b9e37a-0501-4cc6-b4a9-74a2fc2b9cf0", "name": "8a32d994-7583-4752-b441-2f6e02dd5b1d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0137187800791063, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5284248988065299, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8e10c4cb-8e1d-4851-8987-ae9eace6d8d0", "name": "f6478ee6-3a57-4bba-94ee-56361b3e3858", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "39b9e37a-0501-4cc6-b4a9-74a2fc2b9cf0"}}}]}, {"uuid": "3f42414d-fc02-43d7-91a3-6ad9eb55c592", "name": "load_p1rlv132_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41960437-e2e6-4746-89c2-81c81602ca1b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8e10c4cb-8e1d-4851-8987-ae9eace6d8d0"}}}}, {"uuid": "69280a7b-28c9-4d85-877f-dd1248b7248b", "name": "1f19a2e4-25a5-407b-8454-2be5b63972a5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0137187800791063, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5284248988065299, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "164140b5-919a-4b39-93e9-6db867cf4762", "name": "7fb42886-cae4-444b-92db-facbd41dab72", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "69280a7b-28c9-4d85-877f-dd1248b7248b"}}}]}, {"uuid": "ae0dee1d-c463-4e8f-ae0a-82810bc1685d", "name": "load_p1rlv132_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41960437-e2e6-4746-89c2-81c81602ca1b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "164140b5-919a-4b39-93e9-6db867cf4762"}}}}, {"uuid": "fb417fec-33bd-4084-8f82-6d11748f2047", "name": "a9795b2b-4b87-4110-8a14-78afd0d49d64_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.046232297850773, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7285366000251032, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3064bd57-4ffc-4deb-8735-6d075a485d9f", "name": "96357b25-56ee-4f8d-9da2-a3e83610934a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fb417fec-33bd-4084-8f82-6d11748f2047"}}}]}, {"uuid": "e3f43d0b-7c14-40bf-8d16-648e9e170049", "name": "load_p1rlv133_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31dc8280-eb14-4f87-85d7-8eae17013fe7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3064bd57-4ffc-4deb-8735-6d075a485d9f"}}}}, {"uuid": "f985227a-08b1-43a1-8e47-a22acac88d68", "name": "710369ac-a8d0-4c38-93a8-46b84dd1d8a7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.046232297850773, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7285366000251032, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d3331dab-f1a0-40fa-81e9-63713ffc2b94", "name": "f3f63640-6d2d-44e9-9790-fa94d65bf3a0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f985227a-08b1-43a1-8e47-a22acac88d68"}}}]}, {"uuid": "a4597a71-10a4-4e27-b3cf-0a95e3532ec2", "name": "load_p1rlv133_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31dc8280-eb14-4f87-85d7-8eae17013fe7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d3331dab-f1a0-40fa-81e9-63713ffc2b94"}}}}, {"uuid": "c93cb390-e017-4571-8bdc-951a3c7934e2", "name": "09bdff91-2037-4c18-ba7b-a04c66ed49b6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.749950841708346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2019248045205122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c73fef17-c587-4230-b668-dff1db537a28", "name": "154ddc07-d012-4fdd-9991-5b1ca9c716dd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c93cb390-e017-4571-8bdc-951a3c7934e2"}}}]}, {"uuid": "347cf23e-5bb8-4ca9-bf4c-f95fe4d6aed4", "name": "load_p1rlv134_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "425bdcfa-9753-4ef5-bb38-9e014ae779dc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c73fef17-c587-4230-b668-dff1db537a28"}}}}, {"uuid": "a92c0e23-02e5-4950-8be3-f8c9e8c4591d", "name": "2a8bc7d6-7297-4097-8dfd-1c6494a98a65_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.749950841708346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2019248045205122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e19a7870-8be5-4d5e-8652-16b430939a8d", "name": "868745ea-71dc-4326-a57b-7f61af0d2ab9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a92c0e23-02e5-4950-8be3-f8c9e8c4591d"}}}]}, {"uuid": "266eefbd-2122-4ee6-9540-516ad6889ef8", "name": "load_p1rlv134_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "425bdcfa-9753-4ef5-bb38-9e014ae779dc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e19a7870-8be5-4d5e-8652-16b430939a8d"}}}}, {"uuid": "95ec5f2b-b490-42f4-8ee2-9ca02be4da2c", "name": "45df5033-41fe-4d79-b003-347016b718a8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.42648220197083947, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17627708866943506, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d5775010-abb6-406d-84d4-10da14e4a029", "name": "fb2cf978-0429-4a12-969a-5bb046e1aa57", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "95ec5f2b-b490-42f4-8ee2-9ca02be4da2c"}}}]}, {"uuid": "941505d8-b4bb-420d-ad6e-167a2ebd2c3a", "name": "load_p1rlv135_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbdefe7a-517b-495b-88b8-dcf15a9429ff"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d5775010-abb6-406d-84d4-10da14e4a029"}}}}, {"uuid": "bad99740-a014-4f26-bf2e-7387137923c8", "name": "79792ac0-069b-447a-a970-b0bc553883d1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.42648220197083947, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17627708866943506, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50f95d46-0ac6-48ff-95ad-00338df71ef2", "name": "0394e936-e0cc-4fd8-8fcc-9cfc4332f150", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bad99740-a014-4f26-bf2e-7387137923c8"}}}]}, {"uuid": "bc126c2c-755e-4200-8d8f-962a94855b9c", "name": "load_p1rlv135_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbdefe7a-517b-495b-88b8-dcf15a9429ff"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50f95d46-0ac6-48ff-95ad-00338df71ef2"}}}}, {"uuid": "9f3b6ec2-dfbd-409b-a2c6-525a9ff654ff", "name": "39164d37-47d5-414e-8a10-a40a4ab83b24_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.42648220197083947, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17627708866943506, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d0e4956c-feaf-42b5-9ee4-c963a2a26935", "name": "15277c3b-7fa8-4388-a600-0b7f97c905a4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9f3b6ec2-dfbd-409b-a2c6-525a9ff654ff"}}}]}, {"uuid": "2d231a9c-7512-4f43-8277-1487fc229652", "name": "load_p1rlv136_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b45d086e-8e0d-42f4-a8ec-6d3a9579a96b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d0e4956c-feaf-42b5-9ee4-c963a2a26935"}}}}, {"uuid": "fdafdf3b-73b3-453a-87c2-2df8084bb98c", "name": "ca06e9b0-4117-4eff-bf25-bbfe498d6009_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.42648220197083947, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17627708866943506, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9cc6a9b8-8464-4424-b3b3-4d2cc9d97dd5", "name": "25312fce-d271-4992-a5e5-ddb8d59e7ff5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fdafdf3b-73b3-453a-87c2-2df8084bb98c"}}}]}, {"uuid": "1cdcc87f-f562-47be-91b4-f48dd1775575", "name": "load_p1rlv136_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b45d086e-8e0d-42f4-a8ec-6d3a9579a96b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9cc6a9b8-8464-4424-b3b3-4d2cc9d97dd5"}}}}, {"uuid": "0086126c-4d2d-4fc7-96e6-03d8d4cac9d3", "name": "f3fd3a9b-7921-449c-8770-15e549537819_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7847716543397305, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8567239737527961, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "505c74a3-c96f-4c02-a72f-d0f90e0437a1", "name": "a5512df3-8486-4353-af08-2fc11ccb626e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0086126c-4d2d-4fc7-96e6-03d8d4cac9d3"}}}]}, {"uuid": "c16d5956-bcaf-4e19-bbb4-a2d9c7c50985", "name": "load_p1rlv137_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54ca5205-5b71-42f2-8e24-c24f768a7a5c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "505c74a3-c96f-4c02-a72f-d0f90e0437a1"}}}}, {"uuid": "db699610-605d-413c-8ff6-f42b1562e0cf", "name": "286e5f6e-1ae8-4f8b-8acf-22c703327965_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7847716543397305, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8567239737527961, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6a7d692c-a117-4247-8287-b3f354c302fd", "name": "bbcd4a4f-a0ec-4892-93b6-87e6bf5f4997", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "db699610-605d-413c-8ff6-f42b1562e0cf"}}}]}, {"uuid": "b741fa39-d83e-4937-81da-2c267cac540d", "name": "load_p1rlv137_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54ca5205-5b71-42f2-8e24-c24f768a7a5c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6a7d692c-a117-4247-8287-b3f354c302fd"}}}}, {"uuid": "682e5096-46cf-4550-a322-c4ab8b58f66e", "name": "fa81627e-9a5c-4990-b78c-b6a34af2247d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3464174292990054, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8802812503815668, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f4389e8d-94fe-424c-ab95-9398108a0c98", "name": "02f8a4fb-67f2-46db-a057-566bd62223f2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "682e5096-46cf-4550-a322-c4ab8b58f66e"}}}]}, {"uuid": "a13d6162-7194-4ef1-9525-14c7daa057bc", "name": "load_p1rlv138_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea9e5f8c-8477-403c-9d3a-911c4e5ab5c8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f4389e8d-94fe-424c-ab95-9398108a0c98"}}}}, {"uuid": "31687a1d-b0c0-4fdf-b82d-bc308aabefd0", "name": "177ce2f3-6ac7-4c15-946b-12bb54870dea_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3464174292990054, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8802812503815668, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "95e0385d-8d99-4303-b089-6f2829172f7e", "name": "2dc4c056-d7cb-4f5b-a146-5befc5393a1a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "31687a1d-b0c0-4fdf-b82d-bc308aabefd0"}}}]}, {"uuid": "dcd3190d-0b75-48da-8b22-cc7d18a61203", "name": "load_p1rlv138_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea9e5f8c-8477-403c-9d3a-911c4e5ab5c8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "95e0385d-8d99-4303-b089-6f2829172f7e"}}}}, {"uuid": "b1a1e4ef-f08c-4195-99b1-234afd20d768", "name": "d35c880e-0ed2-4c1d-a930-f6984f03b3be_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d041a1dd-add3-4622-b9a3-3318ab972cfa", "name": "785d81d9-4a00-4d38-8461-704019109825", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b1a1e4ef-f08c-4195-99b1-234afd20d768"}}}]}, {"uuid": "9d10a1c4-d3ce-4795-a27d-1d6c70a0f364", "name": "load_p1rlv139_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b515111-3455-471a-aba8-92c82624a195"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d041a1dd-add3-4622-b9a3-3318ab972cfa"}}}}, {"uuid": "659e1f70-3a5c-4fe3-b175-ae2b937d5072", "name": "72b548ea-22ba-43cf-8b60-272236c601e5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "315adfbb-45bd-4aef-b975-b33240c1baaa", "name": "1bc333f7-d58e-4446-a171-8fb28b2036bd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "659e1f70-3a5c-4fe3-b175-ae2b937d5072"}}}]}, {"uuid": "d2dc7c04-36f4-41ec-9710-1fc569efcafc", "name": "load_p1rlv139_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b515111-3455-471a-aba8-92c82624a195"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "315adfbb-45bd-4aef-b975-b33240c1baaa"}}}}, {"uuid": "034b2e6c-75c2-4ec8-b37f-f667c33a99c5", "name": "088bc71c-b927-42da-9b52-f7e65500ea96_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.209150400251685, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2205162973996855, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "19a5d21e-61b9-463f-9019-13b26647196e", "name": "d56465c5-95d2-4be6-bfed-60413c14803f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "034b2e6c-75c2-4ec8-b37f-f667c33a99c5"}}}]}, {"uuid": "5f355174-2450-47b3-8699-e6f5ab544c8c", "name": "load_p1rlv140_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47b7d9f8-ca72-4a77-af67-74ee561f7f10"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "19a5d21e-61b9-463f-9019-13b26647196e"}}}}, {"uuid": "63bb7c2e-c2b4-40b4-b982-f5fa68dd616f", "name": "a7a86684-abbb-4eba-bb58-2664751d69a4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.209150400251685, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2205162973996855, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "15829817-4b74-4da6-8886-2ceb190a7d6a", "name": "26b8d213-19be-48eb-9e30-43b201a201e2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "63bb7c2e-c2b4-40b4-b982-f5fa68dd616f"}}}]}, {"uuid": "078efe7b-e8c2-4b0a-8724-18637fa38f8e", "name": "load_p1rlv140_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47b7d9f8-ca72-4a77-af67-74ee561f7f10"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "15829817-4b74-4da6-8886-2ceb190a7d6a"}}}}, {"uuid": "eda14cb6-5a95-4051-932e-1aaf61b27387", "name": "d6dac862-178a-429b-b99c-fdc55e6ecf30_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.151480398016275, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.11399865992730775, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "44a09194-ef66-4ffc-878e-d75e35308de7", "name": "4ebb344d-82dc-499a-9c40-c415cfc56f7b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eda14cb6-5a95-4051-932e-1aaf61b27387"}}}]}, {"uuid": "fc3a2ef7-4d6c-4256-850a-721c0c740e0d", "name": "load_p1rlv141_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb69a6a9-3eaf-4fc3-82be-0eec77455a82"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "44a09194-ef66-4ffc-878e-d75e35308de7"}}}}, {"uuid": "38871f1f-85b5-4b3b-af00-f94e78fd4eae", "name": "f5a7f030-cd46-44b6-a68d-99662bdd96d6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.151480398016275, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.11399865992730775, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ae6826a1-1972-422c-8398-5a8baefac133", "name": "ad2ef29a-cada-4bf4-a441-2bfd7068ee86", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "38871f1f-85b5-4b3b-af00-f94e78fd4eae"}}}]}, {"uuid": "ca231060-9de7-45a2-b588-e95b9061ebb8", "name": "load_p1rlv141_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb69a6a9-3eaf-4fc3-82be-0eec77455a82"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ae6826a1-1972-422c-8398-5a8baefac133"}}}}, {"uuid": "11514d8b-42b8-44ec-b770-f820efbc3626", "name": "b3b92ae2-3d05-4a7c-b72e-47c331e7a3f2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9029063430901945, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8881818750925909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b0adad72-9bdc-41ec-8a01-baf64e8da41f", "name": "bee29b63-4f88-4222-881d-7ad9afaad9c8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "11514d8b-42b8-44ec-b770-f820efbc3626"}}}]}, {"uuid": "c9a36645-5b3b-40d0-853e-4c24719fea23", "name": "load_p1rlv143_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "46cd88d0-b2c4-492a-af3d-d9ae886d0089"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b0adad72-9bdc-41ec-8a01-baf64e8da41f"}}}}, {"uuid": "8e1d9cc7-4be8-4426-beb6-ad38017a7ab5", "name": "8e55faaf-86ba-45d3-9a60-33e353e2969a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9029063430901945, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8881818750925909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b5c00744-639c-41ea-96ca-c1f09800fc3a", "name": "66ff36d7-5b31-4475-84ee-e223b11c1d90", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8e1d9cc7-4be8-4426-beb6-ad38017a7ab5"}}}]}, {"uuid": "b13f3e78-16f0-46ea-a28a-6bd223312662", "name": "load_p1rlv143_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "46cd88d0-b2c4-492a-af3d-d9ae886d0089"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b5c00744-639c-41ea-96ca-c1f09800fc3a"}}}}, {"uuid": "6efba862-2084-4197-8842-7a4e3e7cbe55", "name": "ca51752d-e464-48b4-89bb-3cab4889764a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9024769844937937, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4778358547008617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4618b6bb-3217-4c40-81e5-337da883d284", "name": "d6d818ce-0039-4dc7-92b2-95d506c66f3d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6efba862-2084-4197-8842-7a4e3e7cbe55"}}}]}, {"uuid": "6dfbe3aa-d122-4dd0-adae-a501ba9ce94f", "name": "load_p1rlv144_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b7dbf54-f6bc-4e20-b2f3-8c63a44dd993"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4618b6bb-3217-4c40-81e5-337da883d284"}}}}, {"uuid": "9b3d7385-18b7-4c12-87d4-28509ac71622", "name": "8b41385c-d319-435b-878e-1abaaf86169d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9024769844937937, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4778358547008617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cfddae17-0b75-403e-8c4b-abf94636a6da", "name": "bd484a3e-574e-4959-9058-98b297b870ba", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9b3d7385-18b7-4c12-87d4-28509ac71622"}}}]}, {"uuid": "651d58ec-8f41-4a45-87bf-325c1f4cd4ab", "name": "load_p1rlv144_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b7dbf54-f6bc-4e20-b2f3-8c63a44dd993"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cfddae17-0b75-403e-8c4b-abf94636a6da"}}}}, {"uuid": "596e3b96-2e23-4f01-90df-cd04c0f0f94c", "name": "a681cdc9-4b50-46b7-8c08-2d8bffbb7144_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5478654763148745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5646840796232575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "64174510-2d82-4a24-91df-ec21ad651c75", "name": "94f59b95-5d40-449e-982f-797659492681", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "596e3b96-2e23-4f01-90df-cd04c0f0f94c"}}}]}, {"uuid": "2c8ea63a-1b5f-4324-8f57-3190d9421025", "name": "load_p1rlv145_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1704e67-dfa3-4a6b-a3f4-7ebba9d27537"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "64174510-2d82-4a24-91df-ec21ad651c75"}}}}, {"uuid": "26401bca-ca42-4b35-96cb-c083a9c82b1e", "name": "40b6c346-3a2f-4b29-a7b6-747e501f9941_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5478654763148745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5646840796232575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c752fc03-cc98-431f-bdef-07b64f2c5114", "name": "7fd9d5e3-d134-4162-8ad5-5b57c4b8eb78", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "26401bca-ca42-4b35-96cb-c083a9c82b1e"}}}]}, {"uuid": "033e9386-a8ca-41a0-b92b-a0e2abb19756", "name": "load_p1rlv145_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1704e67-dfa3-4a6b-a3f4-7ebba9d27537"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c752fc03-cc98-431f-bdef-07b64f2c5114"}}}}, {"uuid": "b304661b-8f12-449a-8f41-f02a8a8c80e2", "name": "9e58965c-d189-4f80-86fe-7f5fb1bf3fcf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8309189378455104, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6069744647018672, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a64c60f-711f-4c47-ad03-c64950c901a1", "name": "2e28f36a-4df6-4074-806a-a131dde98fd9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b304661b-8f12-449a-8f41-f02a8a8c80e2"}}}]}, {"uuid": "b2e7ecf7-0e4c-444d-8662-2650fcbbdf78", "name": "load_p1rlv146_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da2538bd-189b-4699-823b-ed459d94b422"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a64c60f-711f-4c47-ad03-c64950c901a1"}}}}, {"uuid": "c0bafccd-dcf8-4967-8689-6d2494d0b36c", "name": "2c66c959-d921-48eb-b2fe-7f3c076980f0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8309189378455104, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6069744647018672, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6fdf8d05-e64c-493f-945d-164885fb3387", "name": "fd78a750-5fc4-431b-bf2f-b6cdba25cfd6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c0bafccd-dcf8-4967-8689-6d2494d0b36c"}}}]}, {"uuid": "23482389-4769-43fa-8b5f-093a6f1dbc66", "name": "load_p1rlv146_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da2538bd-189b-4699-823b-ed459d94b422"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6fdf8d05-e64c-493f-945d-164885fb3387"}}}}, {"uuid": "d96d1306-0ca2-444f-bd3a-14e7ce69c39c", "name": "79ef7648-0e4f-47f3-9552-070c1daf8b7e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.3355603190645935, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9435041304985261, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4e188817-c68e-43ff-b1b3-d8b89b6313f8", "name": "2e1300a2-b142-4cf7-b428-44ae641f3b33", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d96d1306-0ca2-444f-bd3a-14e7ce69c39c"}}}]}, {"uuid": "44fd75f0-0108-48e9-91b3-66e8bd787b59", "name": "load_p1rlv147_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "070d9a60-c6f2-424c-bd0f-66c52d349f0c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4e188817-c68e-43ff-b1b3-d8b89b6313f8"}}}}, {"uuid": "4f99e19b-0c10-4aa1-a8d2-49724a8051ad", "name": "6d8d7835-2274-4924-9a05-990a5b79ed12_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.3355603190645935, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9435041304985261, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "56054ae6-3682-47ac-a664-23bb779230da", "name": "2dbd413d-f2d8-468d-9705-7dd87674f442", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4f99e19b-0c10-4aa1-a8d2-49724a8051ad"}}}]}, {"uuid": "bcbb05e5-afc4-4792-87d5-52bea1b4b377", "name": "load_p1rlv147_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "070d9a60-c6f2-424c-bd0f-66c52d349f0c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "56054ae6-3682-47ac-a664-23bb779230da"}}}}, {"uuid": "58883f3e-fe3f-4f4a-b34b-a98fbc741f50", "name": "f46cb48f-eaaa-4ffb-9352-6dc4011d0fbb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8322096344455547, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7991596594888891, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "467b71c4-89b2-41bb-a169-4113dd36049d", "name": "2f7cc6c9-2406-41b0-a256-0bf75d1c8276", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58883f3e-fe3f-4f4a-b34b-a98fbc741f50"}}}]}, {"uuid": "6592f31a-023d-4bb6-bff2-43300edf4703", "name": "load_p1rlv148_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa8af0a4-4d55-41e4-83d1-4fe349920e38"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "467b71c4-89b2-41bb-a169-4113dd36049d"}}}}, {"uuid": "f3b31322-4a81-4bd1-81b9-bcc2afe6fdf5", "name": "4dffbdd2-5c5c-4770-bd8d-35347cb4a8c6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8322096344455547, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7991596594888891, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b2180f75-44f0-42d8-88f3-f1346b5158b9", "name": "abba6f94-a44b-4def-8331-63b5e15689d0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f3b31322-4a81-4bd1-81b9-bcc2afe6fdf5"}}}]}, {"uuid": "222251ff-23fc-4c53-b67b-5d791152038f", "name": "load_p1rlv148_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa8af0a4-4d55-41e4-83d1-4fe349920e38"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b2180f75-44f0-42d8-88f3-f1346b5158b9"}}}}, {"uuid": "b18a0e35-3710-4ac6-8659-b140bcddb054", "name": "0f329b93-21bb-46c9-81b6-04efa26cb4d7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4856814769108864, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8267323554826451, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c299fdab-1be2-44cc-96e2-6818b024cf1a", "name": "7a46dd14-b0c7-4773-90e5-a77125b014aa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b18a0e35-3710-4ac6-8659-b140bcddb054"}}}]}, {"uuid": "7d8e659d-c80b-4311-97a0-4bccb4c72934", "name": "load_p1rlv149_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "063e89ea-6dd0-404f-abfb-21686f3041ed"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c299fdab-1be2-44cc-96e2-6818b024cf1a"}}}}, {"uuid": "d9f6edac-f43c-41d2-9855-3e5d321a5557", "name": "c29d21b1-bfc1-401b-98a6-fdb5f43c054f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4856814769108864, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8267323554826451, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c7ac34c1-7a2f-4670-8fc2-8f72b68d431a", "name": "be672881-04e7-4295-b56d-1fd88d691219", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d9f6edac-f43c-41d2-9855-3e5d321a5557"}}}]}, {"uuid": "9b6cbfe0-93bd-470e-a7c2-b85265e317a0", "name": "load_p1rlv149_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "063e89ea-6dd0-404f-abfb-21686f3041ed"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c7ac34c1-7a2f-4670-8fc2-8f72b68d431a"}}}}, {"uuid": "2755d3e5-9a94-44af-9a22-f04a395f82bd", "name": "77049928-0e3f-4ffa-a8eb-edc8a66ec445_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4363904318707768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7717292253609904, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6bf52870-b994-4ac6-a78e-f09d89990a8e", "name": "7d6ae7c1-3b27-41a7-bd5b-17fbd7f49a36", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2755d3e5-9a94-44af-9a22-f04a395f82bd"}}}]}, {"uuid": "c9162abe-7b46-4442-b723-313a2f140b94", "name": "load_p1rlv150_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b9979ec-4e43-4feb-a617-28191e9dd9d8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6bf52870-b994-4ac6-a78e-f09d89990a8e"}}}}, {"uuid": "cc94c4fb-e6d2-4258-99f2-80cc480e81f8", "name": "56adb619-83e9-403c-b508-c29461a2acdf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4363904318707768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7717292253609904, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "923dac6e-dac9-4b6a-88b9-f90ce0af4d15", "name": "12e1cf39-01d8-4998-9719-5ff883dbd7c5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cc94c4fb-e6d2-4258-99f2-80cc480e81f8"}}}]}, {"uuid": "38d8ebb4-802c-4053-9ffc-dad485aa76c3", "name": "load_p1rlv150_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b9979ec-4e43-4feb-a617-28191e9dd9d8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "923dac6e-dac9-4b6a-88b9-f90ce0af4d15"}}}}, {"uuid": "4a96dd5c-c1cf-4bda-8faa-6c177cac16a0", "name": "6cdc4319-9a33-4da3-a140-3084bd8675d2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.371919551924291, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7891526087442801, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e6169458-cf82-4d24-9754-3f8c1bd6a7fc", "name": "045e2802-f6e2-4e20-8056-bdb6b7c4142f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4a96dd5c-c1cf-4bda-8faa-6c177cac16a0"}}}]}, {"uuid": "0cda9978-67ba-4878-a11b-9c6683e1b644", "name": "load_p1rlv151_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "345b5c48-cd35-418e-bc08-50c06f5dff09"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e6169458-cf82-4d24-9754-3f8c1bd6a7fc"}}}}, {"uuid": "fd0d566a-eb29-49c1-b499-db0fef89ceeb", "name": "410cbe2a-d7b3-412a-b5a5-1d5e77cbc28c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.371919551924291, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7891526087442801, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "24d62fae-b96b-411a-a99a-e92cb4e74a46", "name": "bb1f18f6-0cad-4534-b8bd-2d97729aef38", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fd0d566a-eb29-49c1-b499-db0fef89ceeb"}}}]}, {"uuid": "43d28bc8-e7f1-4742-8311-292f1796ff7c", "name": "load_p1rlv151_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "345b5c48-cd35-418e-bc08-50c06f5dff09"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "24d62fae-b96b-411a-a99a-e92cb4e74a46"}}}}, {"uuid": "bb9f90a6-0e2c-480b-abaf-2caaf59df40d", "name": "b55ad8a0-3c28-4dad-be50-b52c8aad5aef_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1381537134701794, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42848704523913217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6aa1373f-1958-42b9-8eb0-2aa8619f5abb", "name": "96966198-f951-452f-9a42-229b7fd330b1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bb9f90a6-0e2c-480b-abaf-2caaf59df40d"}}}]}, {"uuid": "1a727775-9d19-408b-aa4a-28ef8bac6e71", "name": "load_p1rlv152_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25b891ce-797a-4a4d-b664-4225fba806c4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6aa1373f-1958-42b9-8eb0-2aa8619f5abb"}}}}, {"uuid": "50d91c7a-0fab-42dd-9308-c8d005ab6688", "name": "351c5236-9e35-4471-833c-dc9da4e7e306_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1381537134701794, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42848704523913217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4cb66431-8190-4793-9e90-23f1cdb1cb25", "name": "7f716e77-1e2b-4a56-95cb-dc1a96d25136", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "50d91c7a-0fab-42dd-9308-c8d005ab6688"}}}]}, {"uuid": "21fe823b-b24d-4c2c-a164-eb7bf5f9c199", "name": "load_p1rlv152_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25b891ce-797a-4a4d-b664-4225fba806c4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4cb66431-8190-4793-9e90-23f1cdb1cb25"}}}}, {"uuid": "ad038307-bf63-4325-aaf3-7073f33fc11c", "name": "41412b4d-fb58-44a6-af9d-eac87b314ace_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.567401274738218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6497123013243786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9589c15d-3d6c-4085-a001-b653159fda79", "name": "a02eb120-8919-40e8-9966-15fa07f620d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ad038307-bf63-4325-aaf3-7073f33fc11c"}}}]}, {"uuid": "3ad36ef3-8756-4f87-937c-8b411a17f018", "name": "load_p1rlv153_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ebbe09dd-7560-4eff-9e32-803f14b4ce7c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9589c15d-3d6c-4085-a001-b653159fda79"}}}}, {"uuid": "3d6b9794-cc04-4a3c-8508-8c264e5770c7", "name": "b1908562-73cc-4fb3-aad9-109c6f7b8693_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.567401274738218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6497123013243786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "28f9d670-2046-4464-aebf-afde5cb96ba4", "name": "c59fabc3-bbb0-4ff5-99d0-a1e491b30a5e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3d6b9794-cc04-4a3c-8508-8c264e5770c7"}}}]}, {"uuid": "88e1d099-0fe2-4cf9-9696-2cd72fa5929d", "name": "load_p1rlv153_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ebbe09dd-7560-4eff-9e32-803f14b4ce7c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "28f9d670-2046-4464-aebf-afde5cb96ba4"}}}}, {"uuid": "ff01f4eb-995f-4752-b365-bba2b9223d49", "name": "4dc3d221-3521-416a-b5e5-46ff24f0c3e1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6235247805381197, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5206515777483778, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "47d88b93-6ce7-4903-bac2-9c34abcdfe9e", "name": "de3bf5d6-9721-4ffb-96a8-2dde7c116d90", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ff01f4eb-995f-4752-b365-bba2b9223d49"}}}]}, {"uuid": "fe71efd1-7d64-4c4a-ac74-446d584f4c5e", "name": "load_p1rlv154_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ccdfbc7-d3a6-4f74-ad32-25ff11a2e3b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "47d88b93-6ce7-4903-bac2-9c34abcdfe9e"}}}}, {"uuid": "0614c34a-114c-40d2-a8c2-2d1a046eeed4", "name": "99ae88cc-c8fe-4c25-9c77-2dbe4f065ce2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6235247805381197, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5206515777483778, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "addce10f-e9ee-486f-b31b-e941253493a8", "name": "b453f214-b5c5-42a8-837e-0a729f59b610", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0614c34a-114c-40d2-a8c2-2d1a046eeed4"}}}]}, {"uuid": "8c98171c-35a4-4280-bc3b-6e54c2785507", "name": "load_p1rlv154_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ccdfbc7-d3a6-4f74-ad32-25ff11a2e3b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "addce10f-e9ee-486f-b31b-e941253493a8"}}}}, {"uuid": "5fd7bfc3-e074-4c73-af9b-c9afd6066292", "name": "551775ff-9f39-42b0-830d-e330ac2d1791_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.108706484347092, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9298438232381894, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f6a57a7d-a667-482a-be6f-e450371abb29", "name": "aeea7305-281e-4470-af56-a22592c1c7ff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5fd7bfc3-e074-4c73-af9b-c9afd6066292"}}}]}, {"uuid": "18f9ee3a-9c84-4710-beab-a5bb978ec532", "name": "load_p1rlv155_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2452d5af-5aba-4d4b-8cd9-27a95fe6b34d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f6a57a7d-a667-482a-be6f-e450371abb29"}}}}, {"uuid": "3a47ae95-d7cb-4523-93c2-230fb065d89b", "name": "c95d57ba-4cf0-4346-bd63-3f17baf8f9cb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.108706484347092, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9298438232381894, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e6a822a7-b8d1-4bb4-9a75-ab11afaa184f", "name": "d725a57f-a94b-41c7-a169-d697f57dadb1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3a47ae95-d7cb-4523-93c2-230fb065d89b"}}}]}, {"uuid": "8e9ded2b-34fc-4efa-8c3c-dca36a27429a", "name": "load_p1rlv155_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2452d5af-5aba-4d4b-8cd9-27a95fe6b34d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e6a822a7-b8d1-4bb4-9a75-ab11afaa184f"}}}}, {"uuid": "948fd41c-89a2-42c7-af9e-4063c6d0b180", "name": "fc5973c9-b174-43c4-8cdf-7a83995d7b04_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7537427041030689, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.37349948863112625, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "abf8107a-a30b-4316-a765-541a893ce591", "name": "c1c669b4-f5a0-43c9-968d-302e6cb121e3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "948fd41c-89a2-42c7-af9e-4063c6d0b180"}}}]}, {"uuid": "5d8cfb02-36f5-4d97-980b-1c7bedf17ccf", "name": "load_p1rlv156_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f607e6b-9540-4845-9f0c-6c334eb0e807"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "abf8107a-a30b-4316-a765-541a893ce591"}}}}, {"uuid": "935ef1c3-72e1-436e-bc15-f545f6b403df", "name": "5191cadc-6d3e-48d3-8e78-1380f62e6742_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7537427041030689, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.37349948863112625, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82073bd9-631c-47e5-9919-c1b48349e72d", "name": "469bcafc-5ecb-4cc8-890e-900f450020c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "935ef1c3-72e1-436e-bc15-f545f6b403df"}}}]}, {"uuid": "9db2b8c0-d340-498e-859f-41389b498e69", "name": "load_p1rlv156_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f607e6b-9540-4845-9f0c-6c334eb0e807"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "82073bd9-631c-47e5-9919-c1b48349e72d"}}}}, {"uuid": "bbb9af72-1b21-4719-acda-ff7ca257537b", "name": "fdb83a04-3f11-4a69-8f2d-ca418085afcd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.095937077188644, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9158391685680531, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10e19920-3702-415e-83da-bc6eb9517f3d", "name": "78eb2ff1-0b89-4b2a-85b9-3fe469d614d9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bbb9af72-1b21-4719-acda-ff7ca257537b"}}}]}, {"uuid": "5f7c3981-32f3-4b90-bed6-25b9d01fc927", "name": "load_p1rlv157_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4355a473-4643-4f72-afe8-80ce773ca8e8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10e19920-3702-415e-83da-bc6eb9517f3d"}}}}, {"uuid": "175e92fa-a479-4df5-b9c0-237f7d031d69", "name": "3d0ce575-376f-4ba3-a146-4f3a1499a5e3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.095937077188644, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9158391685680531, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7a5f84b4-faf1-4cf8-8940-65f8f657c018", "name": "2c3d94ef-3441-4046-9dc3-92fa55fe52a1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "175e92fa-a479-4df5-b9c0-237f7d031d69"}}}]}, {"uuid": "fbe3ca78-571d-4ae4-860f-991921cbbcaf", "name": "load_p1rlv157_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4355a473-4643-4f72-afe8-80ce773ca8e8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7a5f84b4-faf1-4cf8-8940-65f8f657c018"}}}}, {"uuid": "8cdd07ea-28f2-4a13-9de0-e26993ff5341", "name": "4ee96c19-3806-4064-94b6-eeb44c18e551_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8840297592093247, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9532534150802011, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "899d4299-2a0e-4ae5-b0b9-1390e0fcc535", "name": "d78e16a0-bffa-49d7-ac9b-8b36e97e82d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8cdd07ea-28f2-4a13-9de0-e26993ff5341"}}}]}, {"uuid": "8de3c047-03a9-4aba-9e64-f6ab42a642a6", "name": "load_p1rlv158_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1cd7284-17fb-4382-a29d-dd8c5bfd7541"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "899d4299-2a0e-4ae5-b0b9-1390e0fcc535"}}}}, {"uuid": "0c8d86db-65a9-4c7d-af73-c853594251e4", "name": "3eb1bae5-9be0-415d-844d-fc6a79d0ac7e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8840297592093247, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9532534150802011, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "778bb6f1-53ee-4071-b98f-50c7a63b20a1", "name": "4146d0a9-becf-474c-90ce-ea5b8fc8844e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0c8d86db-65a9-4c7d-af73-c853594251e4"}}}]}, {"uuid": "e41e26d9-4dcc-4f50-ac1a-dc1a9f2fdeed", "name": "load_p1rlv158_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1cd7284-17fb-4382-a29d-dd8c5bfd7541"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "778bb6f1-53ee-4071-b98f-50c7a63b20a1"}}}}, {"uuid": "d68b2e1c-0cbf-46c4-913b-f7d400006ae7", "name": "9f845cf9-8a36-4ec0-bba1-3983a908f7e8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.374654272561421, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4772638197977597, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e6f5f0bb-c625-4ae5-80f5-ea8be9ed6188", "name": "27cc8d66-ef3e-4ce0-bd01-0b412d29c7b7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d68b2e1c-0cbf-46c4-913b-f7d400006ae7"}}}]}, {"uuid": "83135160-8d59-48d8-89f3-a13a2e5a666d", "name": "load_p1rlv159_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0ae6c02-c29e-4bf9-b1d4-ecc7e37e7de2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e6f5f0bb-c625-4ae5-80f5-ea8be9ed6188"}}}}, {"uuid": "3cfea8c2-b638-47d9-b2ac-ef32e676f050", "name": "1b8759f5-240f-4f14-bb73-b120b24050f6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.374654272561421, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4772638197977597, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c5d16f5c-a56f-4d89-9ba4-0e87a25ae1e4", "name": "9632e604-abee-4381-a8da-ef8a40bb3c5d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3cfea8c2-b638-47d9-b2ac-ef32e676f050"}}}]}, {"uuid": "3c29eda9-ab0f-4b5b-998f-68e75fdc6376", "name": "load_p1rlv159_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0ae6c02-c29e-4bf9-b1d4-ecc7e37e7de2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c5d16f5c-a56f-4d89-9ba4-0e87a25ae1e4"}}}}, {"uuid": "b9ddc7cb-eb34-46b9-8a35-4504b55c290c", "name": "7428b4e2-67cc-42de-88ea-cbee112a2d17_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.442421826038779, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9571745396829384, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6c0b14c3-394b-4868-b1d3-5d7e95265052", "name": "bb27f7e2-8d35-46f2-a528-59ef9a686b87", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b9ddc7cb-eb34-46b9-8a35-4504b55c290c"}}}]}, {"uuid": "f9560b22-0982-4d00-8b31-a029346a264e", "name": "load_p1rlv160_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd2fae5a-e5dd-4ad4-8acc-422de00ae83e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6c0b14c3-394b-4868-b1d3-5d7e95265052"}}}}, {"uuid": "af343575-9b10-43f2-9a7b-35f179fb9685", "name": "2970a6c2-819e-455d-a867-daa7338e6234_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.442421826038779, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9571745396829384, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c5f5f382-7b6d-4bae-a150-b970b5ee303f", "name": "ea134b02-0b2f-4a4f-be02-7a0cd5401977", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "af343575-9b10-43f2-9a7b-35f179fb9685"}}}]}, {"uuid": "8133c7b7-4525-4ca0-a609-363f6efc7d54", "name": "load_p1rlv160_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd2fae5a-e5dd-4ad4-8acc-422de00ae83e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c5f5f382-7b6d-4bae-a150-b970b5ee303f"}}}}, {"uuid": "328d8c3e-0611-4a1e-b691-dc74728b29c5", "name": "af682978-efe2-47c9-a254-c3c11fc0d851_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0ff97ff9-a544-4896-8d12-a2f3de1ce723", "name": "589c8a5d-0a70-4a9c-9b5b-8a80a9d0e905", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "328d8c3e-0611-4a1e-b691-dc74728b29c5"}}}]}, {"uuid": "0628e2d9-5b47-44ae-87b3-22c5f8b928e3", "name": "load_p1rlv161_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4842819e-3f17-47da-a8bf-c3402c3c00b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0ff97ff9-a544-4896-8d12-a2f3de1ce723"}}}}, {"uuid": "8a242f35-2441-445f-8acf-0276263fed46", "name": "25040100-e180-4f0b-8556-982cff6f28b8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bfc0ef6d-9d70-45f9-b448-da730be6008c", "name": "195665b6-661d-4ba2-b416-f11523a8957c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a242f35-2441-445f-8acf-0276263fed46"}}}]}, {"uuid": "9f3ac376-58ea-4e67-860a-22cb60ee101b", "name": "load_p1rlv161_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4842819e-3f17-47da-a8bf-c3402c3c00b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bfc0ef6d-9d70-45f9-b448-da730be6008c"}}}}, {"uuid": "0c866a74-80b4-4de8-ab0f-8af6d5e99cc7", "name": "0d2de203-31e0-414e-86dd-b5ecdf23e2ed_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8374792851175116, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3203908676737591, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2dd7a99d-e8de-47c1-9d13-4bf7dd8f3b77", "name": "9df39120-b9c3-4747-bddc-d26981985449", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0c866a74-80b4-4de8-ab0f-8af6d5e99cc7"}}}]}, {"uuid": "cdccd113-7867-400e-9bfc-673b6504e025", "name": "load_p1rlv162_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3fcd1ee-e6e0-4ca3-aacf-cc527b07482a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2dd7a99d-e8de-47c1-9d13-4bf7dd8f3b77"}}}}, {"uuid": "d2422cd1-af9d-45dc-8c9c-7288cfc5a26b", "name": "bde66f82-50c0-41b3-b680-4d7bddd49d6e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8374792851175116, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3203908676737591, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0f1052fb-c159-459d-bf3e-737a269fb736", "name": "d2e1b2a4-fcf6-4c91-a810-c2e59000da86", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d2422cd1-af9d-45dc-8c9c-7288cfc5a26b"}}}]}, {"uuid": "b329cd69-c9b0-4878-ac79-27870fdbbe7e", "name": "load_p1rlv162_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3fcd1ee-e6e0-4ca3-aacf-cc527b07482a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0f1052fb-c159-459d-bf3e-737a269fb736"}}}}, {"uuid": "96517525-e2c4-4d6d-aa67-3c78f0ede687", "name": "6c840f55-ebfd-43cc-9769-381ffbf540d5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.255903801273714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9789336651099453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f698c194-b969-456c-9959-4ebbdb8258f3", "name": "98aae7db-d220-421a-acee-cdddcf98741b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "96517525-e2c4-4d6d-aa67-3c78f0ede687"}}}]}, {"uuid": "008c43f1-f5ea-44de-b929-426e8ea6a8ac", "name": "load_p1rlv163_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "471bad88-4514-4b02-aa1a-1d2aaa15557f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f698c194-b969-456c-9959-4ebbdb8258f3"}}}}, {"uuid": "156e6d01-cde8-4bc7-a0cc-ba85375c0343", "name": "0dd99461-0697-4bf2-90a3-f24b43c866bf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.255903801273714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9789336651099453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10d3b8af-7878-4ddd-a72f-04d0d6d5de38", "name": "9fe24db1-0e1e-490c-8da4-76b48f4d9ed3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "156e6d01-cde8-4bc7-a0cc-ba85375c0343"}}}]}, {"uuid": "b5ba124b-48a8-4202-9869-3c0a2845cefa", "name": "load_p1rlv163_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "471bad88-4514-4b02-aa1a-1d2aaa15557f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10d3b8af-7878-4ddd-a72f-04d0d6d5de38"}}}}, {"uuid": "ae092096-ac18-4e26-8ec9-767664b6f311", "name": "469ae3f3-b681-4f98-a225-2dfd2453a804_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.634023352191214, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2934174607236286, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "11d28751-2dc2-4643-ade5-056105ccf36c", "name": "0b58701e-29db-4654-93f6-13763353b25f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ae092096-ac18-4e26-8ec9-767664b6f311"}}}]}, {"uuid": "b4e237d5-30ca-442d-8332-301533b55a01", "name": "load_p1rlv164_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61460072-bdc5-4a70-96fa-8ecfa71623f4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "11d28751-2dc2-4643-ade5-056105ccf36c"}}}}, {"uuid": "b59962b8-410d-4873-8558-4dbe02ecb8fe", "name": "a0671619-9046-42c9-b892-98a56904909a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.634023352191214, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2934174607236286, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dc46ae19-b1eb-4477-87fb-ee2ba7499455", "name": "154e2be4-cb1f-478b-9e94-8f93b38d66c4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b59962b8-410d-4873-8558-4dbe02ecb8fe"}}}]}, {"uuid": "1b646ba1-bbb4-4502-b283-b240fdd81ce4", "name": "load_p1rlv164_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61460072-bdc5-4a70-96fa-8ecfa71623f4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dc46ae19-b1eb-4477-87fb-ee2ba7499455"}}}}, {"uuid": "bb4fa101-0970-45f9-a5db-ebad81aacb1c", "name": "8361d8ec-a547-4a5a-8787-e617c97ed8fb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.916354724025409, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9016755043678467, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3f4de5dd-749e-4e87-909a-e035a519fcdd", "name": "cc92d500-45e7-42e1-ae9b-13d8bb2f2fff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bb4fa101-0970-45f9-a5db-ebad81aacb1c"}}}]}, {"uuid": "0b35ffa2-4fa3-4ab2-84fa-08aaa61760c4", "name": "load_p1rlv165_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e7880c9-0932-4395-abf9-2274e400f280"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3f4de5dd-749e-4e87-909a-e035a519fcdd"}}}}, {"uuid": "d3f6d1d9-b892-4800-b2a5-7dad65648d40", "name": "96e6e68a-0043-4f91-9a2a-5b6b8b9aa970_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.916354724025409, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9016755043678467, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1d03c60f-63b8-4b5a-baba-e7e71a7e9690", "name": "ce24492e-0581-4b7b-918c-0c97ae277ba3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d3f6d1d9-b892-4800-b2a5-7dad65648d40"}}}]}, {"uuid": "468330c1-1a98-49d0-9b35-871faab87fbc", "name": "load_p1rlv165_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e7880c9-0932-4395-abf9-2274e400f280"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1d03c60f-63b8-4b5a-baba-e7e71a7e9690"}}}}, {"uuid": "768dc0db-9dfb-47b2-aac9-7217b1b0cbee", "name": "dc3081f4-2919-49bb-96a1-2f070a62ebc3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0137187800791063, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5284248988065299, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d9c6e84e-8f73-401c-88e7-e518034cdd97", "name": "4934d0b2-27f2-4f83-a544-8afa0eb732ae", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "768dc0db-9dfb-47b2-aac9-7217b1b0cbee"}}}]}, {"uuid": "0c371311-d835-4725-93c2-38caf4340198", "name": "load_p1rlv166_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21d333f7-7426-4fa6-8ab2-c6118055ece1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d9c6e84e-8f73-401c-88e7-e518034cdd97"}}}}, {"uuid": "085d4979-f0e8-4a81-b766-4edceb93e79e", "name": "bf77bda4-8aa9-4eba-89dd-84980b634d82_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0137187800791063, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5284248988065299, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b0114f8e-42b3-4cf6-bf82-0b5a74d34435", "name": "585e8691-2f0c-4b61-84c7-c44b11f02892", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "085d4979-f0e8-4a81-b766-4edceb93e79e"}}}]}, {"uuid": "4842b8c9-483a-4000-b8e4-e92115d3362f", "name": "load_p1rlv166_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21d333f7-7426-4fa6-8ab2-c6118055ece1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b0114f8e-42b3-4cf6-bf82-0b5a74d34435"}}}}, {"uuid": "e3d3f347-2cc5-4163-b195-f4feba41a7fd", "name": "76df4f4c-e521-4730-8e19-8b809222dc22_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.438316346451239, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6915244213249778, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bad3c5a9-944e-4467-ae32-a39f8d2467de", "name": "98d01b2b-b1f1-4250-9f1d-41f70ff5d409", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e3d3f347-2cc5-4163-b195-f4feba41a7fd"}}}]}, {"uuid": "edf53ba9-4c8d-48d7-8acc-70d10e07dd76", "name": "load_p1rlv167_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5187e006-621e-4c15-9604-0272ae62887c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bad3c5a9-944e-4467-ae32-a39f8d2467de"}}}}, {"uuid": "f4199876-e02c-443b-8a34-a7b5569f45be", "name": "52482e87-111f-48b8-acd8-e110e76daa7d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.438316346451239, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6915244213249778, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "549f4461-fd8e-4e37-b9ef-b0d574c9ce4d", "name": "793f7997-5e15-45b1-9c9c-14738a369d89", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f4199876-e02c-443b-8a34-a7b5569f45be"}}}]}, {"uuid": "c9d4f26a-59c2-47b0-82c3-cad585ad2f67", "name": "load_p1rlv167_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5187e006-621e-4c15-9604-0272ae62887c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "549f4461-fd8e-4e37-b9ef-b0d574c9ce4d"}}}}, {"uuid": "8214ae9e-a98a-47c7-bf7a-310a375c354b", "name": "d0eb3fa8-a282-44f2-8e59-84f3c3ccbabd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.639612501586281, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0977377571892493, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6742fd24-2bc0-431d-b30d-4dc763353622", "name": "ef806c3e-41af-4e54-9db4-fd35effb1c39", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8214ae9e-a98a-47c7-bf7a-310a375c354b"}}}]}, {"uuid": "9cf5e44e-7289-461c-87bd-47979c4da230", "name": "load_p1rlv168_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "470fe3ed-5b24-438a-ba6d-cdd9f774e5ad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6742fd24-2bc0-431d-b30d-4dc763353622"}}}}, {"uuid": "3cb772b7-4657-4d8c-b525-85caf30002e2", "name": "166a84a5-46bf-463f-a30d-ac639c12ef84_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.639612501586281, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0977377571892493, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1a1b7a21-7a66-4d44-a8a0-09649c122699", "name": "3cef0015-9633-4bbc-97cd-151780b2104d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3cb772b7-4657-4d8c-b525-85caf30002e2"}}}]}, {"uuid": "6cab2d7f-7acf-4f13-a544-9b4d10e51b6e", "name": "load_p1rlv168_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "470fe3ed-5b24-438a-ba6d-cdd9f774e5ad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1a1b7a21-7a66-4d44-a8a0-09649c122699"}}}}, {"uuid": "383399fd-31e7-4be4-99a8-6525097749ec", "name": "43b935d3-1a10-4adf-9410-46944594ccb7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.684904254134122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42635901069761617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f44b0661-5eed-4671-8837-51e4c5c01de3", "name": "d59b11a3-8cb6-49c5-95c5-60f8d1118f4b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "383399fd-31e7-4be4-99a8-6525097749ec"}}}]}, {"uuid": "1fd860c2-0753-45b8-baa9-3dc334d13763", "name": "load_p1rlv169_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e326756-7ead-4099-a065-9f2de5693197"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f44b0661-5eed-4671-8837-51e4c5c01de3"}}}}, {"uuid": "eeae9ebe-ad30-4b1e-b628-12e620aa68ec", "name": "3718c088-26e2-46ec-8ae8-2a1e26017e5f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.684904254134122, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42635901069761617, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fb2e612d-b1e6-4bc5-984a-fa6fe8fb9df5", "name": "2772f810-9754-4bd1-9c53-5e888bfd626a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eeae9ebe-ad30-4b1e-b628-12e620aa68ec"}}}]}, {"uuid": "9dc019fb-8428-44bd-a4e0-82641341dbcd", "name": "load_p1rlv169_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e326756-7ead-4099-a065-9f2de5693197"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fb2e612d-b1e6-4bc5-984a-fa6fe8fb9df5"}}}}, {"uuid": "1bd5db0e-8d36-4d2c-b7c0-993a45f5424c", "name": "c90b3a0a-1417-4e01-974d-e7498f6e4231_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7812856221781264, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.29493523962554685, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c16e7813-54ab-4d3e-b29f-e5b94c25edef", "name": "91b96749-f6a7-4aaa-8ef1-27ee7f1d7098", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1bd5db0e-8d36-4d2c-b7c0-993a45f5424c"}}}]}, {"uuid": "4b2fd52a-2379-40cc-b0e7-5233f221bf47", "name": "load_p1rlv170_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f7dbd18-1cbe-49d3-b490-3c46cf8e37f1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c16e7813-54ab-4d3e-b29f-e5b94c25edef"}}}}, {"uuid": "59335f20-1ff3-4163-8844-d0bccb5c1dd8", "name": "fd8c620e-38b3-4a2f-8207-a0ec2ba4c534_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7812856221781264, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.29493523962554685, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c7a14033-b9a3-4231-8824-61308ee49db0", "name": "ed26bab6-3b3c-4663-8439-73d41ffca540", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "59335f20-1ff3-4163-8844-d0bccb5c1dd8"}}}]}, {"uuid": "0b0521c1-45dd-4a1f-8d44-d93a0eaf0b10", "name": "load_p1rlv170_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f7dbd18-1cbe-49d3-b490-3c46cf8e37f1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c7a14033-b9a3-4231-8824-61308ee49db0"}}}}, {"uuid": "86845da4-bb7d-4900-9c00-c6be83efd8ca", "name": "a6904d60-3eda-4ac0-9945-67a01bc5e6d7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7997673490012955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.772957044307952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f8da8d9c-2705-4d59-9e4a-99d23673be05", "name": "b389c1ff-fe5b-4cb8-8253-5b50ddf92ea7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "86845da4-bb7d-4900-9c00-c6be83efd8ca"}}}]}, {"uuid": "b861f8df-f309-4edb-a49e-5abbc43f7496", "name": "load_p1rlv174_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1186295-59ff-48a8-b31d-0f7cd40df1ab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f8da8d9c-2705-4d59-9e4a-99d23673be05"}}}}, {"uuid": "6cada501-95eb-4758-ae39-fe53048531d5", "name": "27711f95-8460-40c6-9724-4f27c75fc0eb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7997673490012955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.772957044307952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7d080bb8-d0ae-4e18-a50e-af67f4a22adb", "name": "38120dbf-2229-4a03-a721-2a227cae7ab8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6cada501-95eb-4758-ae39-fe53048531d5"}}}]}, {"uuid": "5ef0ca22-9b94-4e1c-87b4-ce7fb335b3f8", "name": "load_p1rlv174_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1186295-59ff-48a8-b31d-0f7cd40df1ab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7d080bb8-d0ae-4e18-a50e-af67f4a22adb"}}}}, {"uuid": "32d09fa6-77c4-4c1b-bb61-807cfc09ff43", "name": "c480aefe-44ba-44d6-9062-01b0ef9fd938_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2562100051220524, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.06533962175647968, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e648a41d-31dd-415d-a78b-6f023dfdd28d", "name": "a2b00fbb-9868-459e-91e2-464d724fbbb0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "32d09fa6-77c4-4c1b-bb61-807cfc09ff43"}}}]}, {"uuid": "13593603-abcb-4843-9994-1637c6b41373", "name": "load_p1rlv175_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905e9287-bdb6-44e0-b0af-f59ab4ad4d8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e648a41d-31dd-415d-a78b-6f023dfdd28d"}}}}, {"uuid": "93daaec5-a80d-4c09-a45c-c9e4efe1553c", "name": "4d0e3ca5-98a1-478f-99f3-4c2abe4fecec_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2562100051220524, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.06533962175647968, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "912c8def-e8ae-4a1e-9ad7-0e603c08a529", "name": "4f5b5bcc-a092-48a9-8a4b-19eb8dbf520b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "93daaec5-a80d-4c09-a45c-c9e4efe1553c"}}}]}, {"uuid": "a64c2d9e-7189-4d59-a635-5f3fea3d070e", "name": "load_p1rlv175_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905e9287-bdb6-44e0-b0af-f59ab4ad4d8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "912c8def-e8ae-4a1e-9ad7-0e603c08a529"}}}}, {"uuid": "698bdf1b-1257-4c31-85f8-bacacde1eb47", "name": "babffe7a-fa6f-40a4-a3d7-450c5fbb1531_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6697995975485909, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.41657408993223344, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "407f8084-cfa0-4adf-afe9-7ad0952ad9a8", "name": "180a6a17-b6a5-4caa-a113-9d8208147f1c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "698bdf1b-1257-4c31-85f8-bacacde1eb47"}}}]}, {"uuid": "9d01e606-f835-479b-b804-4f81eef27ac3", "name": "load_p1rlv176_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "931c8cee-89fe-447d-8788-af1e5f9f8775"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "407f8084-cfa0-4adf-afe9-7ad0952ad9a8"}}}}, {"uuid": "99e5d20b-27ce-4d39-b06a-3c44e17dcda4", "name": "e30615b3-a943-46c8-b4e7-5117468922d2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6697995975485909, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.41657408993223344, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e2b94225-1356-4853-bfa6-176c0a433f9b", "name": "a37c0ac8-c612-4374-9882-9cc962aea7b7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "99e5d20b-27ce-4d39-b06a-3c44e17dcda4"}}}]}, {"uuid": "036940e5-1dde-482f-8a28-985360b13eb8", "name": "load_p1rlv176_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "931c8cee-89fe-447d-8788-af1e5f9f8775"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e2b94225-1356-4853-bfa6-176c0a433f9b"}}}}, {"uuid": "8e2d83b6-5e0f-4403-98cc-978ff787b4ca", "name": "42c249c8-a282-4f34-9fa9-663f5b585402_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4063851199490187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16385595528128288, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "811492a9-f6d4-4b8c-80c0-f863291bfcf7", "name": "e9a6c2c9-1727-417b-9248-d78e56d70a45", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8e2d83b6-5e0f-4403-98cc-978ff787b4ca"}}}]}, {"uuid": "29c19a1f-f23f-4648-97ec-b4c8b61f383f", "name": "load_p1rlv177_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "090d6084-5cc6-473d-99c0-a6309571d633"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "811492a9-f6d4-4b8c-80c0-f863291bfcf7"}}}}, {"uuid": "df803f20-308e-4fe6-844b-d129655543e6", "name": "13f10b9b-e510-446b-a882-74a62ae51dc9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4063851199490187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16385595528128288, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c1b844f0-b3b1-4af5-9201-f97f01504132", "name": "6662538b-8582-480c-b4b6-1ccd18cd440c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "df803f20-308e-4fe6-844b-d129655543e6"}}}]}, {"uuid": "d329efae-e466-4e6b-8fb8-24065f82fa03", "name": "load_p1rlv177_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "090d6084-5cc6-473d-99c0-a6309571d633"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c1b844f0-b3b1-4af5-9201-f97f01504132"}}}}, {"uuid": "29520ab8-c7dd-456f-b4db-2b585ff86051", "name": "9b00560f-85e3-4b99-9b63-bb2a4d907d18_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3919966449037446, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.25526897783955566, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eae97a79-5117-4b6a-9c56-897666501298", "name": "e875f6e1-849f-4df7-bbbb-0b36d4833763", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "29520ab8-c7dd-456f-b4db-2b585ff86051"}}}]}, {"uuid": "44644e90-47ad-4157-a7f5-2dd87e9b3172", "name": "load_p1rlv178_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9debf70-62f4-4870-ad8b-bffc4bc4ad3f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eae97a79-5117-4b6a-9c56-897666501298"}}}}, {"uuid": "0a3b3667-f263-4612-968a-c393477614a0", "name": "8428cf0f-b9e1-4726-a653-40ca39b5e34e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3919966449037446, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.25526897783955566, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0c3ae6b3-dc8d-4283-af06-4e0a124a1079", "name": "d670777d-88ca-4db2-925a-b09d361259bd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0a3b3667-f263-4612-968a-c393477614a0"}}}]}, {"uuid": "d628e1e1-2c23-427b-86a1-8a5297639e27", "name": "load_p1rlv178_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9debf70-62f4-4870-ad8b-bffc4bc4ad3f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0c3ae6b3-dc8d-4283-af06-4e0a124a1079"}}}}, {"uuid": "ea998f67-c04a-4494-98c4-064f1a9f2336", "name": "fa1d8715-c8b9-4f92-9f0d-5f38fd60569d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2601927423507288, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13915962527089715, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "428a7349-08ef-465b-8e74-58ac9d3fe537", "name": "75b7c4a3-cf9d-4665-8a74-5895e7bd2fb6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ea998f67-c04a-4494-98c4-064f1a9f2336"}}}]}, {"uuid": "7a97bfc2-9f49-403d-b794-3f116aba6c9a", "name": "load_p1rlv179_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb03260b-d7d7-4779-ab2c-37c9a1e34d66"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "428a7349-08ef-465b-8e74-58ac9d3fe537"}}}}, {"uuid": "4ad41fa7-5d89-41fa-b3e1-a38addab38d1", "name": "0d7f7e8e-b66a-4544-9ac6-0f8fae22229d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2601927423507288, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13915962527089715, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "58befe5b-f61e-4628-a5d3-a10a18294c9b", "name": "73013f72-7f5e-476f-8c35-1d744b0417ef", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4ad41fa7-5d89-41fa-b3e1-a38addab38d1"}}}]}, {"uuid": "651090f6-dde3-4268-b0f7-9b8f180e98f5", "name": "load_p1rlv179_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb03260b-d7d7-4779-ab2c-37c9a1e34d66"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "58befe5b-f61e-4628-a5d3-a10a18294c9b"}}}}, {"uuid": "ed163f46-f389-484a-94fc-a9b331c41498", "name": "a216477c-85cb-41c9-82fb-76a01c8fefea_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2659851154673674, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7880475847724098, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "842b74ac-4c55-4a3a-ab3f-7c4334c352ef", "name": "601af922-d980-495a-8064-27c3cdb0b3bd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ed163f46-f389-484a-94fc-a9b331c41498"}}}]}, {"uuid": "45f3055c-726c-485c-bdd8-1117acdc412a", "name": "load_p1rlv285_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d3a86df-2ac5-4959-b857-562795ce84ba"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "842b74ac-4c55-4a3a-ab3f-7c4334c352ef"}}}}, {"uuid": "c8ac35f5-ff97-4160-9768-d475b43c0558", "name": "b3738bf2-a2c6-46f6-8e66-384b2579bf42_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2659851154673674, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7880475847724098, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a258932-2782-467b-b763-1a702c820449", "name": "a51f40ca-ad49-4ccd-b8ac-c34e8ab16026", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c8ac35f5-ff97-4160-9768-d475b43c0558"}}}]}, {"uuid": "6479420b-32b6-41c7-a90d-68d7d778a703", "name": "load_p1rlv285_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d3a86df-2ac5-4959-b857-562795ce84ba"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0a258932-2782-467b-b763-1a702c820449"}}}}, {"uuid": "1c177bae-3836-497a-9053-d4ead03fbd3c", "name": "e3d417f2-bf21-4f7c-8f2f-5987506a39da_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7aa7dc8d-fb03-4602-a9c7-2c8a3f57e11e", "name": "fe88390d-2742-4c94-9aac-b19ed839235a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1c177bae-3836-497a-9053-d4ead03fbd3c"}}}]}, {"uuid": "4556cea0-a96e-4e33-89b2-36d259fbf452", "name": "load_p1rlv337_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57b88281-b728-4779-82b1-4cc9eb4b41b1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7aa7dc8d-fb03-4602-a9c7-2c8a3f57e11e"}}}}, {"uuid": "f1501d64-73bc-43d1-b883-0c114a180b3f", "name": "b1dd7efd-f593-4adc-8da9-7256bd29e94f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "472244fd-1054-4fbf-a42e-caac2dc2776d", "name": "41ced716-013c-4d5c-a7ed-ff05a893b220", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f1501d64-73bc-43d1-b883-0c114a180b3f"}}}]}, {"uuid": "9ea99031-1a73-4860-8941-03176411c5bf", "name": "load_p1rlv337_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57b88281-b728-4779-82b1-4cc9eb4b41b1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "472244fd-1054-4fbf-a42e-caac2dc2776d"}}}}, {"uuid": "d204acfa-ed37-4a6b-95eb-8de35bfabbc1", "name": "515ac681-bc87-4785-98b5-8f8a94c86b73_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2045141672666357, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3046267940472902, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7289962d-1ada-451f-b2c9-e221764be8f2", "name": "21c661fe-a346-4b28-aa4e-23df3068ca6c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d204acfa-ed37-4a6b-95eb-8de35bfabbc1"}}}]}, {"uuid": "6cbf86aa-64e8-43d6-a2b2-92c2c3acfb3f", "name": "load_p1rlv338_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6b2aba6-a289-4a50-a131-2064047d1341"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7289962d-1ada-451f-b2c9-e221764be8f2"}}}}, {"uuid": "42fbd9cf-1d1c-4abc-85bd-116b6ddf9bfa", "name": "14038502-db61-4a46-b69e-1c39f41d22a3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2045141672666357, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3046267940472902, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1ee17721-78a2-48e2-b84d-63ff7d2774e2", "name": "854c52d5-f691-4c09-b7aa-2defe0872bad", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "42fbd9cf-1d1c-4abc-85bd-116b6ddf9bfa"}}}]}, {"uuid": "c5486f4c-d67c-491a-a3b9-721e60f5bfe3", "name": "load_p1rlv338_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6b2aba6-a289-4a50-a131-2064047d1341"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1ee17721-78a2-48e2-b84d-63ff7d2774e2"}}}}, {"uuid": "6439cd2a-e885-4ff0-886a-36d603472278", "name": "6809aa00-7d60-4f12-bccd-5637e38d38b4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.749950841708346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2019248045205122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "05626810-c934-47c1-9b5e-0be633089952", "name": "9e0a0824-5fa4-4caa-a072-29dd33106920", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6439cd2a-e885-4ff0-886a-36d603472278"}}}]}, {"uuid": "3923f8d0-d62f-4abe-a647-2a3892b503e7", "name": "load_p1rlv340_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb4797d6-b46e-4058-8985-d9f4b660f0a7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "05626810-c934-47c1-9b5e-0be633089952"}}}}, {"uuid": "6c6c9a34-29b0-4314-9fe4-d2c4c3852ee8", "name": "96a9059b-9ada-4807-a11d-56012857b21e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.749950841708346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2019248045205122, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6e25347e-dd30-4db8-99fb-a71a4a549692", "name": "ab84c3c8-001a-4eb0-8134-2b8035150c17", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c6c9a34-29b0-4314-9fe4-d2c4c3852ee8"}}}]}, {"uuid": "eb14f439-9aa1-4079-96fe-45e6e5847e93", "name": "load_p1rlv340_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb4797d6-b46e-4058-8985-d9f4b660f0a7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6e25347e-dd30-4db8-99fb-a71a4a549692"}}}}, {"uuid": "ab205c2d-87ef-4ce5-90dc-e70ae13d27f4", "name": "2005a09f-d78d-4c2c-8b43-2a9aba13acc5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7771517670040275, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8838563298920215, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e6a4afe8-741d-460d-9bcc-f3f77a31cc45", "name": "09c46746-251c-4784-8f41-c60a076be7f3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ab205c2d-87ef-4ce5-90dc-e70ae13d27f4"}}}]}, {"uuid": "561c4565-dc97-4f33-8ad7-42971c29c365", "name": "load_p1rlv341_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54f0ea2c-3849-4ff0-ad8c-e3f65515d178"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e6a4afe8-741d-460d-9bcc-f3f77a31cc45"}}}}, {"uuid": "fbebc68b-d886-4b60-bf1b-7197de9935e5", "name": "d6adca28-a492-4e3b-88dd-c246096a3336_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7771517670040275, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8838563298920215, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "191609e9-fb6c-46b6-95dd-29c9168574f4", "name": "156033c8-3e75-405d-af6e-0eb9dc3de4fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fbebc68b-d886-4b60-bf1b-7197de9935e5"}}}]}, {"uuid": "afcd055b-9509-4910-b384-8233cc9e4e6b", "name": "load_p1rlv341_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54f0ea2c-3849-4ff0-ad8c-e3f65515d178"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "191609e9-fb6c-46b6-95dd-29c9168574f4"}}}}, {"uuid": "f63cca78-c62d-445c-8a2e-215e0eab54d9", "name": "b7983a4b-95a0-45fe-b036-0f5c851a90fa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.4540014644243024, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4055170204295049, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82e02e2e-8676-4814-862e-8c81992484b3", "name": "914f473c-173c-49fd-8ea2-c63522e0a60e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f63cca78-c62d-445c-8a2e-215e0eab54d9"}}}]}, {"uuid": "a78c25f5-e873-4dd8-b731-2c3ff4901b82", "name": "load_p1rlv342_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13754fdb-4039-49fb-b584-8437191dfb2b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "82e02e2e-8676-4814-862e-8c81992484b3"}}}}, {"uuid": "3acb654a-aa3c-4022-915f-e73e57b302cd", "name": "241003e9-2fef-4a7f-9350-0e620c9a620c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.4540014644243024, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.4055170204295049, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3b3af3e2-a813-4fdc-9902-68f5e308c8d5", "name": "9f040f50-6d2d-4f18-bc6f-2ab763c4f055", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3acb654a-aa3c-4022-915f-e73e57b302cd"}}}]}, {"uuid": "29b09a02-af7d-4f10-a1a5-5b3bb8ac37a8", "name": "load_p1rlv342_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13754fdb-4039-49fb-b584-8437191dfb2b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3b3af3e2-a813-4fdc-9902-68f5e308c8d5"}}}}, {"uuid": "46d2407f-a957-4126-a965-30b5fbbce9d9", "name": "48f60e72-1afb-466c-9907-47aa705e05f0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.13715702476687, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3795210711832634, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "780f8a0e-2872-4cd4-9a86-380a9be5d8a3", "name": "45b5032e-3500-4368-8510-e49470dc54fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "46d2407f-a957-4126-a965-30b5fbbce9d9"}}}]}, {"uuid": "7ca6a310-ece1-4515-b89c-91799dfde079", "name": "load_p1rlv343_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0197ef22-9f8f-48a9-84de-663a7ce22773"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "780f8a0e-2872-4cd4-9a86-380a9be5d8a3"}}}}, {"uuid": "31aaa454-e1df-4166-aa08-efef0b899f81", "name": "3e9d777a-3af9-40a3-b89f-aaa24aa1797e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.13715702476687, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3795210711832634, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cbe8525b-a364-4c00-bada-3cb6d22575fa", "name": "85dab30e-30a4-423c-b797-cd08b694cbdd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "31aaa454-e1df-4166-aa08-efef0b899f81"}}}]}, {"uuid": "1404590a-7410-49e3-a904-b7e2f385f6a7", "name": "load_p1rlv343_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0197ef22-9f8f-48a9-84de-663a7ce22773"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cbe8525b-a364-4c00-bada-3cb6d22575fa"}}}}, {"uuid": "004d9144-06c7-40fa-a842-d07cf3457dac", "name": "98219f76-b003-414b-a065-9d41a2cd7b67_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.2930994643856595, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9073205938076818, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a757014b-52d3-40d4-849a-0de412ddaca2", "name": "ffe8f721-ff1c-41e6-adeb-b778f310e837", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "004d9144-06c7-40fa-a842-d07cf3457dac"}}}]}, {"uuid": "f8c96c76-4500-4902-be1e-8995417b8744", "name": "load_p1rlv377_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e1ea241-5329-4db5-996a-df09a9c25687"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a757014b-52d3-40d4-849a-0de412ddaca2"}}}}, {"uuid": "0dcf4eab-54e8-4541-8890-27e214ff59b7", "name": "a5c27446-e8c1-4d61-bfbd-9c778dabe13c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.2930994643856595, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9073205938076818, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "427eb9c6-1136-418d-abde-61d3a2b4041d", "name": "5432649f-73cd-4435-a788-f7d1b72d0967", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0dcf4eab-54e8-4541-8890-27e214ff59b7"}}}]}, {"uuid": "5ad57ec9-af8b-4b00-a356-ecf78415ae20", "name": "load_p1rlv377_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e1ea241-5329-4db5-996a-df09a9c25687"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "427eb9c6-1136-418d-abde-61d3a2b4041d"}}}}, {"uuid": "94c37143-9b5c-474e-99b2-b002ffbfccb4", "name": "3a44a044-db43-48e8-a935-f5e04bd91034_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.651809392632849, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.766759151751063, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "97f2d645-e451-42da-aece-d78a6970ecfc", "name": "a92532cc-0b0b-49f2-ae7c-ea34320889c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "94c37143-9b5c-474e-99b2-b002ffbfccb4"}}}]}, {"uuid": "d80a4f02-d2e1-4f5a-80e8-45a4378ac616", "name": "load_p1rlv378_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3ff63a0-bf3f-43b0-807c-935467b4fe46"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "97f2d645-e451-42da-aece-d78a6970ecfc"}}}}, {"uuid": "0e323603-a17e-407b-83af-62febe03a71c", "name": "ecaa4e08-c740-4566-8601-9a1491659c6e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.651809392632849, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.766759151751063, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "60f67866-5481-4e96-8dd8-0240b485e74e", "name": "76c22656-994c-4b14-9c13-7b9f159d03dc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0e323603-a17e-407b-83af-62febe03a71c"}}}]}, {"uuid": "8d2908f9-6481-4036-9550-bc9b126c0e7a", "name": "load_p1rlv378_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3ff63a0-bf3f-43b0-807c-935467b4fe46"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "60f67866-5481-4e96-8dd8-0240b485e74e"}}}}, {"uuid": "290ee85f-789b-4ced-8dea-094061874c37", "name": "de0a417d-6eae-4df1-9d8e-97a3d259a85c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.096838644473719, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3876192860701033, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6e4cac71-6f88-414e-9062-1212fb7c57de", "name": "d818b75f-425c-4d11-992e-fbae2b838669", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "290ee85f-789b-4ced-8dea-094061874c37"}}}]}, {"uuid": "73f6f7ba-a150-4170-96bf-a852b546e239", "name": "load_p1rlv379_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50225dcf-40bc-44b5-9dec-072ac5b2334e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6e4cac71-6f88-414e-9062-1212fb7c57de"}}}}, {"uuid": "117a6938-112f-45c1-8ae5-c713f9d0a91b", "name": "d1460c02-979f-46df-9f4e-92cd244a3564_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.096838644473719, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3876192860701033, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9f33b4de-345c-4f35-8e17-a9a339cf2869", "name": "022bd3c9-10ad-44f1-b125-18dea4f660f5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "117a6938-112f-45c1-8ae5-c713f9d0a91b"}}}]}, {"uuid": "34220f1f-be21-4cc4-8bb4-4b7eade70fcb", "name": "load_p1rlv379_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50225dcf-40bc-44b5-9dec-072ac5b2334e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9f33b4de-345c-4f35-8e17-a9a339cf2869"}}}}, {"uuid": "b0b45149-b134-4171-b53b-6dd758d0a7a4", "name": "0010f4b1-dc0e-4d20-b884-f9e6ec67d62e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5996895391512607, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5332968923160806, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "24a9217d-fe72-4420-8696-febd57d3910f", "name": "834f12fe-e7fb-4be2-924c-e758065cedb2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b0b45149-b134-4171-b53b-6dd758d0a7a4"}}}]}, {"uuid": "f534baff-d593-496b-b97d-4d6125708942", "name": "load_p1rlv380_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ee07ef9-b7b0-4457-be1c-78e754dbcfc7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "24a9217d-fe72-4420-8696-febd57d3910f"}}}}, {"uuid": "13a657a3-c0e6-4664-bbdf-f01b5a50223b", "name": "cd7ba6a9-1d52-499b-9fde-a6e4f4375cb7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.5996895391512607, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5332968923160806, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fb8d2ec8-db5f-492e-8273-caea9dfba693", "name": "4c6be107-899d-468e-b909-872fd2bdd8a9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "13a657a3-c0e6-4664-bbdf-f01b5a50223b"}}}]}, {"uuid": "75ccf78c-c765-41a6-bb56-37de514dfd86", "name": "load_p1rlv380_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ee07ef9-b7b0-4457-be1c-78e754dbcfc7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fb8d2ec8-db5f-492e-8273-caea9dfba693"}}}}, {"uuid": "9edb37d5-caa0-4b00-9a26-a1aef7b642d2", "name": "2f2f95a1-ff09-4219-9373-12da064989c4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2825930802168721, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5903675615779559, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9f696408-f8d5-435c-b48a-a1b120d685f5", "name": "f3de3b82-5836-4416-aeac-2bd18e3337a2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9edb37d5-caa0-4b00-9a26-a1aef7b642d2"}}}]}, {"uuid": "1201db9d-fab3-415c-8e76-196f246cee65", "name": "load_p1rlv412_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b33ed36-116b-4741-9374-6927bd537427"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9f696408-f8d5-435c-b48a-a1b120d685f5"}}}}, {"uuid": "73ab955f-6770-4bd4-8b30-d11d86f9c7e3", "name": "f5f99842-6cc1-45f2-9739-1134e07d34ec_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2825930802168721, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5903675615779559, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fd4a14f5-a2b4-4f81-821c-6ddbe1b5a91a", "name": "ec891b7a-d6d3-4735-8205-10cb67fdb0b6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "73ab955f-6770-4bd4-8b30-d11d86f9c7e3"}}}]}, {"uuid": "1b537d77-e45c-4ae0-8dea-bc86cdd481b6", "name": "load_p1rlv412_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b33ed36-116b-4741-9374-6927bd537427"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fd4a14f5-a2b4-4f81-821c-6ddbe1b5a91a"}}}}, {"uuid": "84949f0b-d44d-4a0a-9a39-3365a68a2314", "name": "b66335e1-8e77-471c-a647-d252b422f28a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5218330234822437, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6111559757217505, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "956c3863-e83f-4114-89f4-119b9934a4bc", "name": "f20afc4a-dda8-4342-a86a-736bfec026d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "84949f0b-d44d-4a0a-9a39-3365a68a2314"}}}]}, {"uuid": "257f2e68-1456-4e2f-8fe7-fe6c17012ce3", "name": "load_p1rlv413_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8408ac87-a086-46bc-9d88-cca79e17dd62"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "956c3863-e83f-4114-89f4-119b9934a4bc"}}}}, {"uuid": "b2175bbc-4c32-40bb-9689-315b3bcc6d77", "name": "4d03acdd-3b5a-4a2f-9bde-c864876ffc0f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5218330234822437, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6111559757217505, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5607d053-3b06-4109-a565-cfa46dd43ff6", "name": "114afa60-6b70-4d0d-88be-b71871e0249b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b2175bbc-4c32-40bb-9689-315b3bcc6d77"}}}]}, {"uuid": "3cd0305c-20bb-422f-ade5-5c72aa5bf079", "name": "load_p1rlv413_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8408ac87-a086-46bc-9d88-cca79e17dd62"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5607d053-3b06-4109-a565-cfa46dd43ff6"}}}}, {"uuid": "25658ac8-9f93-4d5c-92bd-34dd271c0f9e", "name": "668f02ae-de18-4809-9dd7-a058c84d5985_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.307247144150686, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17783357819798717, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a7fe75cd-0f4b-4b3c-ae8b-71f0919b3f14", "name": "fb1e58e1-f7b4-4623-8ba6-1d4e7529a98e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "25658ac8-9f93-4d5c-92bd-34dd271c0f9e"}}}]}, {"uuid": "35b4e3bb-abfb-4915-bf67-85f1523b4a79", "name": "load_p1rlv414_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec2c1edd-78b1-4436-85cc-2fbc7d880b87"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a7fe75cd-0f4b-4b3c-ae8b-71f0919b3f14"}}}}, {"uuid": "b0150c1f-3a29-4ff7-826e-65ce32bf3402", "name": "3eb4c88f-abac-453f-9d93-39ef129a1d8f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.307247144150686, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.17783357819798717, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ff753503-a4c9-4e5b-a4dd-6695e34a72cf", "name": "30305ae5-0ba2-41ba-8318-c583c284b3b7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b0150c1f-3a29-4ff7-826e-65ce32bf3402"}}}]}, {"uuid": "4bdf7a06-175a-4680-9f3f-f675b8c9e04b", "name": "load_p1rlv414_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec2c1edd-78b1-4436-85cc-2fbc7d880b87"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ff753503-a4c9-4e5b-a4dd-6695e34a72cf"}}}}, {"uuid": "5a4ad912-137b-4edb-80e4-bdf9777227e0", "name": "b5e7052a-bbd0-4b2c-ab85-b69824d5cd68_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5478654763148745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5646840796232575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2d39b745-c630-47ab-9da9-88d2b940963e", "name": "100b605b-2a00-4b97-9ec6-48a6ccc8f450", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5a4ad912-137b-4edb-80e4-bdf9777227e0"}}}]}, {"uuid": "a9fd2337-e212-4577-b3e0-d54b489d242f", "name": "load_p1rlv415_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b54aae8-5a94-4e04-882f-748e1c5f1390"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2d39b745-c630-47ab-9da9-88d2b940963e"}}}}, {"uuid": "9752f792-cdad-4a22-8069-f260252ead54", "name": "79c4a47c-32a3-4c67-9a2b-803120fdff31_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5478654763148745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5646840796232575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5bb18331-14c7-4223-b4e8-25be9b609caa", "name": "46a57404-cee0-492b-84c7-8022e3de81fc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9752f792-cdad-4a22-8069-f260252ead54"}}}]}, {"uuid": "544ef15a-50b6-4c3e-bcfb-05594c086a25", "name": "load_p1rlv415_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b54aae8-5a94-4e04-882f-748e1c5f1390"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5bb18331-14c7-4223-b4e8-25be9b609caa"}}}}, {"uuid": "236f88fc-0b20-4017-9d1f-675e72532aa8", "name": "5d27f300-a078-47fe-8758-e12c363092a5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2437699409140923, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5571842941855458, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fe160672-65f9-422a-9671-4bdc27a622cb", "name": "f786ba5b-b576-41c9-b08d-f961568173e3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "236f88fc-0b20-4017-9d1f-675e72532aa8"}}}]}, {"uuid": "4ff614f9-c0c4-40d4-bfa4-88e78ed45956", "name": "load_p1rlv416_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99abc7dc-8e15-420f-9bc9-0e6229d4dab3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fe160672-65f9-422a-9671-4bdc27a622cb"}}}}, {"uuid": "8aed49d1-541b-4b5c-9f2e-3c5cff27502e", "name": "1e7379ad-fa51-40c3-90eb-d3c5e01261aa_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2437699409140923, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5571842941855458, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1d2b8e34-0dc2-4c63-81ad-6d79487b2e54", "name": "40629f65-fa44-4e45-a92a-3643edc7dc74", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8aed49d1-541b-4b5c-9f2e-3c5cff27502e"}}}]}, {"uuid": "82c78be7-41d1-4915-8907-9969c6287ce0", "name": "load_p1rlv416_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99abc7dc-8e15-420f-9bc9-0e6229d4dab3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1d2b8e34-0dc2-4c63-81ad-6d79487b2e54"}}}}, {"uuid": "55122e3e-f38d-4d1b-86da-c7401f27692e", "name": "fcbad943-9a9c-47ee-a121-c4676330ce18_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1698158732703443, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8490689598373361, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ef1bdc26-4c6e-4e24-8d2f-6bb4f0406a79", "name": "2f060849-2e72-4eea-b384-048580d8e5fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "55122e3e-f38d-4d1b-86da-c7401f27692e"}}}]}, {"uuid": "cd8c15e0-e322-449b-bce6-7a643e578731", "name": "load_p1rlv417_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49dbdd44-a36a-46b5-aef8-558ef7693315"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ef1bdc26-4c6e-4e24-8d2f-6bb4f0406a79"}}}}, {"uuid": "74a63396-c2b6-4f4b-af3f-43efe8e564a9", "name": "c7df32c2-cdf3-45b5-90fc-57e75e7e30b1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1698158732703443, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8490689598373361, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "49b098d1-e734-47b1-a9da-6c4a48a0520a", "name": "30e3bf61-f498-4702-81ef-3a75714458e8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "74a63396-c2b6-4f4b-af3f-43efe8e564a9"}}}]}, {"uuid": "f8e88484-6c6e-45e3-a52a-e736bf05bff7", "name": "load_p1rlv417_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49dbdd44-a36a-46b5-aef8-558ef7693315"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "49b098d1-e734-47b1-a9da-6c4a48a0520a"}}}}, {"uuid": "ab938fa9-a68b-400e-a8e7-d64902836b00", "name": "32268d5a-2da6-4aa3-b876-ced5699e0813_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "58a9e0b3-d78c-4ac9-9604-2a109b6f58a4", "name": "b375611a-bb86-4e95-801c-434f495d8c60", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ab938fa9-a68b-400e-a8e7-d64902836b00"}}}]}, {"uuid": "e39d1d14-3bf8-4464-ae5e-e71464d9438f", "name": "load_p1rlv418_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b54aae8-5a94-4e04-882f-748e1c5f1390"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "58a9e0b3-d78c-4ac9-9604-2a109b6f58a4"}}}}, {"uuid": "1f37b3c6-3ecf-43ad-9e38-3a3dc3a0cc26", "name": "6f014ce4-d03c-4b4e-945a-3d1eba73bdec_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "63163c6c-7cba-4439-850c-9084634f2124", "name": "f4ba3843-c683-4ff0-92b9-ef860b481e32", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1f37b3c6-3ecf-43ad-9e38-3a3dc3a0cc26"}}}]}, {"uuid": "f244f5bf-9001-4806-a729-a2167668ce93", "name": "load_p1rlv418_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b54aae8-5a94-4e04-882f-748e1c5f1390"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "63163c6c-7cba-4439-850c-9084634f2124"}}}}, {"uuid": "55a6f0de-1376-4b1c-b506-a6f1d294f948", "name": "0165d7b3-8b43-47c0-8136-0fbfff30a059_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7500687162104853, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7707974088873139, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b043d947-32fc-4198-b244-45fc8c302d0a", "name": "bf1977d4-2132-4dfc-97c4-179e2d725e4a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "55a6f0de-1376-4b1c-b506-a6f1d294f948"}}}]}, {"uuid": "d8182e93-d5f4-4313-ade2-e469a3bb5d8c", "name": "load_p1rlv419_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7935b9c-b631-432c-a322-9beea73f1fc4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b043d947-32fc-4198-b244-45fc8c302d0a"}}}}, {"uuid": "dd9ae778-2841-4cae-80ae-503efc54ca9c", "name": "6f2adaac-f7b6-408c-9907-ab7bc43f7bee_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7500687162104853, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7707974088873139, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2c97cf19-a37a-4490-bae2-368b37e51bca", "name": "7962d5af-9a27-4c06-9a06-c5c13eb29a5b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dd9ae778-2841-4cae-80ae-503efc54ca9c"}}}]}, {"uuid": "6fba622d-d85c-4cfa-b494-58951b880d4e", "name": "load_p1rlv419_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7935b9c-b631-432c-a322-9beea73f1fc4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2c97cf19-a37a-4490-bae2-368b37e51bca"}}}}, {"uuid": "2a3896a4-969d-48ca-baab-71091982350d", "name": "3cff9dd6-70ac-4346-b7e0-30d7b4c5b2cf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6434260893942235, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2588956175598443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6447e97c-5dd4-4d30-a85b-0bc2e08e72db", "name": "5995a59c-f31e-42b9-b7b1-7f975115716b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2a3896a4-969d-48ca-baab-71091982350d"}}}]}, {"uuid": "0aa79a4c-aea1-4025-9923-8593ea232b24", "name": "load_p1rlv420_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4d7ed8-5ddd-4127-87ab-eb3f48a580c2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6447e97c-5dd4-4d30-a85b-0bc2e08e72db"}}}}, {"uuid": "cdec3867-35e4-4fb8-8021-a976b3d2b085", "name": "9cd4ca9f-c37d-4ab7-9917-3d19039f140a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6434260893942235, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2588956175598443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "25b0c049-def9-4072-b041-5bf6ee171db9", "name": "d0b9cd2b-09f6-49ae-aa4e-88d98a0ebd82", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cdec3867-35e4-4fb8-8021-a976b3d2b085"}}}]}, {"uuid": "94167872-f880-4f9c-af3a-1e15003d571b", "name": "load_p1rlv420_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4d7ed8-5ddd-4127-87ab-eb3f48a580c2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "25b0c049-def9-4072-b041-5bf6ee171db9"}}}}, {"uuid": "3c53efed-5f98-4e1d-9121-1df30d025cc9", "name": "62b17c48-45de-45fd-9566-27fe55bf2649_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6669289783709, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.056901546523703654, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "996a80b3-261b-43a1-91c5-21c792a73994", "name": "8b92c237-c090-4e84-b560-99c2e5c9ae24", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3c53efed-5f98-4e1d-9121-1df30d025cc9"}}}]}, {"uuid": "563cc9c0-de0d-400a-8f79-e346ad461693", "name": "load_p1rlv421_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12dcb168-1bfe-448b-8d9a-f5cb4c61aafe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "996a80b3-261b-43a1-91c5-21c792a73994"}}}}, {"uuid": "7de77097-4a79-4bfe-b65e-29cbf44811c2", "name": "6e0fe43e-b16c-4f7e-9349-d521a6f60151_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6669289783709, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.056901546523703654, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0fde27dd-70e3-42a9-b281-117a5b6ded40", "name": "9d4161dc-d429-4582-96aa-69a6db295ab8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7de77097-4a79-4bfe-b65e-29cbf44811c2"}}}]}, {"uuid": "c797796a-12c9-439b-903d-d720319a9f5d", "name": "load_p1rlv421_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12dcb168-1bfe-448b-8d9a-f5cb4c61aafe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0fde27dd-70e3-42a9-b281-117a5b6ded40"}}}}, {"uuid": "05991d9c-522e-4349-a36c-fd44e2dd07f1", "name": "324242e3-d208-4a59-9931-b871fa753018_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.933146793098512, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9686684100837105, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9cfd504c-4877-491c-912c-fbe81dace76d", "name": "1c7d4e5f-3295-40b5-81f0-0c4074306a7c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "05991d9c-522e-4349-a36c-fd44e2dd07f1"}}}]}, {"uuid": "ff597d6c-e00d-46a3-ba9b-b0e0829959ac", "name": "load_p1rlv422_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa7bb51b-8ba8-4a05-872a-7f5ce084fe88"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9cfd504c-4877-491c-912c-fbe81dace76d"}}}}, {"uuid": "c10cf9cb-91fc-4e09-8683-2c939cc3a0bb", "name": "da66753e-185f-4c0c-a216-68566b61192d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.933146793098512, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9686684100837105, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4d9d9d46-178a-427d-9a33-efb4da3cefdc", "name": "cd2b9061-a50c-466b-be80-2aefbd0c6ce2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c10cf9cb-91fc-4e09-8683-2c939cc3a0bb"}}}]}, {"uuid": "2b22dc58-7860-4849-a2c5-d982f61301e8", "name": "load_p1rlv422_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa7bb51b-8ba8-4a05-872a-7f5ce084fe88"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4d9d9d46-178a-427d-9a33-efb4da3cefdc"}}}}, {"uuid": "33520d61-57c6-4233-8f24-2ca00485cd8f", "name": "b29beaa2-d8b8-47b8-abe4-d78d560ae6a2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0491915565570302, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1506537762556939, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "94a80965-d56a-49e4-99d1-7130b1ec198b", "name": "74a55b1d-5afa-4d60-9810-cb3ec599c176", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "33520d61-57c6-4233-8f24-2ca00485cd8f"}}}]}, {"uuid": "bfa11df5-c4a4-4ab5-9b53-898280a44040", "name": "load_p1rlv423_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c1e9680-f7de-497c-953a-54f4db2899e2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "94a80965-d56a-49e4-99d1-7130b1ec198b"}}}}, {"uuid": "a118a7a2-88e6-42c5-89d9-6b41a6ab039e", "name": "e3e4422d-36a0-4d91-a6e5-924efb122083_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0491915565570302, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1506537762556939, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3182748a-a6d3-48e9-941a-e62456a53155", "name": "98a6588c-0e54-4694-a589-f9f6c573c398", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a118a7a2-88e6-42c5-89d9-6b41a6ab039e"}}}]}, {"uuid": "ccf1c0f6-b41e-4007-9928-38c149b8bd6e", "name": "load_p1rlv423_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c1e9680-f7de-497c-953a-54f4db2899e2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3182748a-a6d3-48e9-941a-e62456a53155"}}}}, {"uuid": "4b837012-2e6a-4090-970b-750f34a1077a", "name": "510ecdc7-345f-4f8a-ac44-5323ed39c728_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.048430097374791, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0714377119995753, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bca6a3d7-d6ea-448c-870e-e5499cb6e352", "name": "cc5170e1-d5c0-4e1e-bcdf-4f86e9f197ee", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4b837012-2e6a-4090-970b-750f34a1077a"}}}]}, {"uuid": "00ca86be-72b4-4af6-9b27-7d5bd262f58b", "name": "load_p1rlv424_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1a91c8c-aabd-4fad-8306-908f186a5744"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bca6a3d7-d6ea-448c-870e-e5499cb6e352"}}}}, {"uuid": "5ee2aac4-fd28-492c-9fbf-e14dcfeb1f56", "name": "565efea5-5d16-4069-b9fe-e78a3eb0aedd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.048430097374791, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0714377119995753, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8491090d-1a03-4ae5-bc2b-f1030da5f1f0", "name": "eb6eef64-a023-4f01-8fcf-4239d57adb32", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5ee2aac4-fd28-492c-9fbf-e14dcfeb1f56"}}}]}, {"uuid": "3d6b51d0-c70c-4997-b523-7e7d83ed4353", "name": "load_p1rlv424_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1a91c8c-aabd-4fad-8306-908f186a5744"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8491090d-1a03-4ae5-bc2b-f1030da5f1f0"}}}}, {"uuid": "4c4d408d-bb5c-4094-8251-2bc68ca55034", "name": "310a4edf-3ccc-42ce-a1a4-b52e410a0b85_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8920557288657344, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21990443750848332, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "65ef3c3d-4484-4297-aba5-6eab04605e0f", "name": "24317571-168d-4b75-88d9-4f43c51bc8cf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4c4d408d-bb5c-4094-8251-2bc68ca55034"}}}]}, {"uuid": "d306d9a0-8ad6-4e4a-9f58-981adc0e3883", "name": "load_p1rlv439_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f771660-4dad-43df-b38b-7da5f6180a25"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "65ef3c3d-4484-4297-aba5-6eab04605e0f"}}}}, {"uuid": "3ce337f3-148a-4e7d-9b88-c7750feec37b", "name": "c3a89a09-dc57-4336-ab2b-cad574ec511b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8920557288657344, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21990443750848332, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7c5b24e7-f210-4a14-978c-d3f2bb483082", "name": "2587354e-c5c0-4ba2-ac28-50bec7d9a608", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3ce337f3-148a-4e7d-9b88-c7750feec37b"}}}]}, {"uuid": "256a6866-9c80-4f16-82fd-de7eaae686d7", "name": "load_p1rlv439_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f771660-4dad-43df-b38b-7da5f6180a25"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7c5b24e7-f210-4a14-978c-d3f2bb483082"}}}}, {"uuid": "5261793a-bf29-4c04-8a01-f2d88cc6722d", "name": "2df4b933-77e6-4412-9d27-90b3200a8993_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 16.24059147715281, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.317949795825311, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c4b10fa3-3e22-4c45-9915-cdb65b4cd420", "name": "2df4b933-77e6-4412-9d27-90b3200a8993_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 16.24059147715281, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.317949795825311, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bef03be8-2fa9-4053-97dd-093966a78bee", "name": "2df4b933-77e6-4412-9d27-90b3200a8993_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 16.24059147715281, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.317949795825311, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0bce5227-fc0c-42c0-a499-e53e72b093b7", "name": "58ae15dd-8489-4925-9705-4352ad3f5f7c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5261793a-bf29-4c04-8a01-f2d88cc6722d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c4b10fa3-3e22-4c45-9915-cdb65b4cd420"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bef03be8-2fa9-4053-97dd-093966a78bee"}}}]}, {"uuid": "b1e406c4-63ea-4a23-9d16-363dd259c73b", "name": "load_p1rlv440", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a23f97bc-e7ef-4f64-9e64-314f4a4e17d8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0bce5227-fc0c-42c0-a499-e53e72b093b7"}}}}, {"uuid": "9894d818-8308-4bbc-9f1e-d9074e63f268", "name": "4ad605bf-5a6e-4a72-9956-2536b0fc3b8a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4856814769108864, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8267323554826451, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c542f525-2856-42c6-9de3-5a1f4448113a", "name": "c9021d60-4ed5-4971-adc8-a100beff3342", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9894d818-8308-4bbc-9f1e-d9074e63f268"}}}]}, {"uuid": "5634e75d-43ab-46fd-a2f7-8f7fd2130563", "name": "load_p1rlv441_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a778b00-482c-4b81-8213-f17202a105fa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c542f525-2856-42c6-9de3-5a1f4448113a"}}}}, {"uuid": "25db585c-f02f-4651-9b6a-4fde07288939", "name": "9e1ec08a-7e98-41f3-aec3-501011911653_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4856814769108864, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8267323554826451, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "308df291-ae5e-463c-b62e-5f1df7e8c52f", "name": "a53be65f-b7dc-44ce-bc4c-8cf2befe86cf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "25db585c-f02f-4651-9b6a-4fde07288939"}}}]}, {"uuid": "67265199-e9b6-4225-bd80-a5303316a244", "name": "load_p1rlv441_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a778b00-482c-4b81-8213-f17202a105fa"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "308df291-ae5e-463c-b62e-5f1df7e8c52f"}}}}, {"uuid": "9487f595-09d1-4a90-beeb-96cd696e5b1d", "name": "6a0a6019-6ae9-4cb3-8832-1f1ae030f058_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.930214175792893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.08514782397789, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "453f8cfc-b505-47b5-a735-bd50a661eff3", "name": "a2903bfb-4002-4629-aa28-100a4ac73fbf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9487f595-09d1-4a90-beeb-96cd696e5b1d"}}}]}, {"uuid": "6d52ad2a-64bf-47cf-8206-746d44da5175", "name": "load_p1rlv442_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cd667a9-c0ef-49ce-b6ee-7e474d9ae761"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "453f8cfc-b505-47b5-a735-bd50a661eff3"}}}}, {"uuid": "216ec404-c4bd-4582-a482-e9adf27caac9", "name": "b58ba976-9653-4229-9372-2c11f1567a42_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.930214175792893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.08514782397789, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2fce8bd0-bd8d-47c6-a08f-db1e08281e9a", "name": "3de521c0-c2e3-4a13-b814-a09c6af31021", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "216ec404-c4bd-4582-a482-e9adf27caac9"}}}]}, {"uuid": "57e4bfe6-8249-482d-9a03-7ad1b74d4c0a", "name": "load_p1rlv442_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cd667a9-c0ef-49ce-b6ee-7e474d9ae761"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2fce8bd0-bd8d-47c6-a08f-db1e08281e9a"}}}}, {"uuid": "9d74f642-1a58-435c-9922-c95f0a9d371a", "name": "ef632798-1b8c-46da-93d8-b0772f08d5f5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7859412473782077, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.762455747973555, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a79978f4-da2d-4611-9e3e-c29a191a7c4c", "name": "0406b84e-e9a4-4851-a993-006de690057e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9d74f642-1a58-435c-9922-c95f0a9d371a"}}}]}, {"uuid": "55cacdf5-2f34-4f91-a63c-67bda85ddefd", "name": "load_p1rlv443_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2100c17-c0e6-47e9-87f8-72016b22dd4b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a79978f4-da2d-4611-9e3e-c29a191a7c4c"}}}}, {"uuid": "b92e692b-da63-4550-a63f-c76c7e192283", "name": "fc7a501e-9c79-454e-be5c-c64f19f2ba0a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7859412473782077, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.762455747973555, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1a7e41f3-f106-40cd-b1c9-468f9c6f612b", "name": "3fce7f30-a9c4-47c8-a6fa-7dcfafdf4e9f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b92e692b-da63-4550-a63f-c76c7e192283"}}}]}, {"uuid": "e74a9ba3-c552-4ba4-ab09-d0ac5a978fcd", "name": "load_p1rlv443_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2100c17-c0e6-47e9-87f8-72016b22dd4b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1a7e41f3-f106-40cd-b1c9-468f9c6f612b"}}}}, {"uuid": "ba02ec92-c842-49fd-a668-18b6792718d9", "name": "315ec56e-8ab3-4602-b49d-bc960908c944_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1461342593009323, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5165512162199262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fc06d0ff-46e7-414c-a1a0-9fec97e1ed9a", "name": "b9047550-16e2-4235-bc0a-cdc6804ea240", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ba02ec92-c842-49fd-a668-18b6792718d9"}}}]}, {"uuid": "97174b9f-f9fe-4498-b530-e8d01c2c0522", "name": "load_p1rlv444_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30f29674-3083-4da2-95e2-a1f11a7eb7f8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fc06d0ff-46e7-414c-a1a0-9fec97e1ed9a"}}}}, {"uuid": "a686f642-643e-46b3-b1c7-f36193346147", "name": "bc70b632-df4e-49f4-a0d2-9586c52f1e8e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1461342593009323, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5165512162199262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "505ad3a5-7414-4fda-b5a4-22e9cc3d8765", "name": "393488ca-8f05-47f5-baaa-e7031131f84e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a686f642-643e-46b3-b1c7-f36193346147"}}}]}, {"uuid": "0a1432fb-6cad-4f4b-901c-b36108aedbff", "name": "load_p1rlv444_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30f29674-3083-4da2-95e2-a1f11a7eb7f8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "505ad3a5-7414-4fda-b5a4-22e9cc3d8765"}}}}, {"uuid": "697c28aa-80d6-4999-95db-098093347a29", "name": "f18426f4-6aa9-4aa9-8422-6d06a64a1243_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3269645363150677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5800133371554559, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a2eef9f-d812-4a82-ba33-8a0826a6fcfd", "name": "f4587ba9-bfbe-4da6-b1be-e6563afc89e6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "697c28aa-80d6-4999-95db-098093347a29"}}}]}, {"uuid": "7cf88d07-693e-4f44-9c68-da32cee2458a", "name": "load_p1rlv445_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d665758-71e1-4478-b39d-671f78f623e5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a2eef9f-d812-4a82-ba33-8a0826a6fcfd"}}}}, {"uuid": "93de3409-9b99-43c0-b071-432c2d9c2e37", "name": "32d226d5-0ef5-4eb9-8b29-fea2daef4505_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3269645363150677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5800133371554559, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0242c41e-10a4-437a-846a-b1ac803df3a3", "name": "212a1fef-e01a-457b-b81f-5e7385b6de57", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "93de3409-9b99-43c0-b071-432c2d9c2e37"}}}]}, {"uuid": "17ce9b5b-47c0-4564-8cd7-2905a8590713", "name": "load_p1rlv445_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d665758-71e1-4478-b39d-671f78f623e5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0242c41e-10a4-437a-846a-b1ac803df3a3"}}}}, {"uuid": "b1ebaca0-d070-46a2-baf4-37aa4cc91c98", "name": "c13b909a-5ec0-4470-982d-8d00eef6dd35_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.810132764673673, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.37076490271254653, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "47e98740-9410-49dc-bed7-d38f767046cf", "name": "626559fd-4634-49fc-8d96-151af2878a5e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b1ebaca0-d070-46a2-baf4-37aa4cc91c98"}}}]}, {"uuid": "9ee773f3-ecf1-4c59-b54e-bb9eedf8e0c5", "name": "load_p1rlv446_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acce3105-f519-491c-921a-df1294795742"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "47e98740-9410-49dc-bed7-d38f767046cf"}}}}, {"uuid": "37f518c3-137c-4023-b8ad-36e6b4dd34a9", "name": "585e9a13-274d-4cc5-bc4d-4885c2b50332_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.810132764673673, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.37076490271254653, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e968e1ca-f469-47e8-bf0f-725ddeedea33", "name": "8e71cb50-7cce-49c4-8217-d40239f37d78", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "37f518c3-137c-4023-b8ad-36e6b4dd34a9"}}}]}, {"uuid": "3bfe5804-c45b-43d3-829e-c49058179c31", "name": "load_p1rlv446_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acce3105-f519-491c-921a-df1294795742"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e968e1ca-f469-47e8-bf0f-725ddeedea33"}}}}, {"uuid": "cbbf026e-f948-4aed-be19-605541ad1420", "name": "cd7abfd6-7f0e-4a14-b7e3-ce91d3553671_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.606460911827677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.1012105340517033, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "80ccb464-d7bc-45ce-88ae-1568eed1f7df", "name": "5b26b15c-9edc-40c4-993a-8e67a69dec14", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cbbf026e-f948-4aed-be19-605541ad1420"}}}]}, {"uuid": "adcf1f3d-8e55-4089-8a27-4424b2d292dd", "name": "load_p1rlv447_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "042873fa-10df-4de0-a040-ac429b8bf7d9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "80ccb464-d7bc-45ce-88ae-1568eed1f7df"}}}}, {"uuid": "17cc2108-3c91-4142-9885-a7ab233506b5", "name": "7a1dda18-7e0c-4e50-aad9-429562d6d099_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.606460911827677, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.1012105340517033, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dbe26070-4c19-4de3-8c5d-ee36a45cb679", "name": "d4c7bb47-ea9a-4416-a135-b1e974019adc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "17cc2108-3c91-4142-9885-a7ab233506b5"}}}]}, {"uuid": "3be041c5-000b-4d30-b42f-7219011ace44", "name": "load_p1rlv447_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "042873fa-10df-4de0-a040-ac429b8bf7d9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dbe26070-4c19-4de3-8c5d-ee36a45cb679"}}}}, {"uuid": "0302377c-9560-40df-b94e-7d47958e7e2f", "name": "36e137af-4506-41c5-88d4-13cc37413ad7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.241801892330501, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.45459688794228914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b76e2b4d-44de-488e-a2b0-fe0ab4d9fc6a", "name": "0fc2a879-4524-4454-8d0c-af1cd2f4ddc9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0302377c-9560-40df-b94e-7d47958e7e2f"}}}]}, {"uuid": "eab61bbb-5785-4d80-921a-cc241f8d8ffb", "name": "load_p1rlv448_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bb83d65-630d-4f1d-8e3d-8937a5a05524"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b76e2b4d-44de-488e-a2b0-fe0ab4d9fc6a"}}}}, {"uuid": "04c1ee12-8cdc-4a0f-871d-eb504a594131", "name": "f9a9fd1c-da0f-499b-8ed9-4e1e75ba09bc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.241801892330501, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.45459688794228914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a9d755ea-888b-484b-b184-f574920bbd11", "name": "31f55e2b-c26e-419e-a2d2-82d1ffb69f9a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "04c1ee12-8cdc-4a0f-871d-eb504a594131"}}}]}, {"uuid": "01eeac4e-7618-4bd3-b15c-a531cc23386a", "name": "load_p1rlv448_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bb83d65-630d-4f1d-8e3d-8937a5a05524"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a9d755ea-888b-484b-b184-f574920bbd11"}}}}, {"uuid": "f6f07fed-ee95-42bb-9b2f-99cdbcc98836", "name": "6c3bbabf-0f96-4ad5-baf6-a8243db13b5f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.290770207979584, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.15121699106508624, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a3c85719-80c2-4257-aadc-5358eebfe11b", "name": "fafbfad2-39cd-4a47-8588-f97146a2a530", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f6f07fed-ee95-42bb-9b2f-99cdbcc98836"}}}]}, {"uuid": "ba3cad7c-886c-4aec-bac5-7664880c8a25", "name": "load_p1rlv449_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "753035df-8705-48eb-92b3-c4bef603b66b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a3c85719-80c2-4257-aadc-5358eebfe11b"}}}}, {"uuid": "9fe52978-caa5-4c34-854e-f4eb88ec571f", "name": "c5e484af-10f2-4d14-882c-a3305f0f92d8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.290770207979584, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.15121699106508624, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "16df0960-22c5-4e53-895d-1586ecbecb14", "name": "6abf24ac-9d6c-4c58-a7a0-73fcf29fa5d6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9fe52978-caa5-4c34-854e-f4eb88ec571f"}}}]}, {"uuid": "fd3f66c4-070f-4567-8f8f-046fd7fc7953", "name": "load_p1rlv449_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "753035df-8705-48eb-92b3-c4bef603b66b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "16df0960-22c5-4e53-895d-1586ecbecb14"}}}}, {"uuid": "bddf4021-0bda-4b02-8584-83cb52ea6df6", "name": "573539e9-7e06-4a2e-8d2e-c61eecc3042d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.074192704000552, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.129078804753558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6529e2b5-4cec-4e70-ae8e-0fb735fc49c7", "name": "e9bfea5c-766e-4e0f-98cd-af636b88abd9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bddf4021-0bda-4b02-8584-83cb52ea6df6"}}}]}, {"uuid": "f56e4e94-fe53-4378-9421-65c4497ea5d9", "name": "load_p1rlv452_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb46f1ae-0cdb-45d1-b389-639cdf345f8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6529e2b5-4cec-4e70-ae8e-0fb735fc49c7"}}}}, {"uuid": "8baa3ae2-948d-4504-8e5f-96544b5bff7d", "name": "0704b8cb-b9f0-413b-844a-b8232935edf0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.074192704000552, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.129078804753558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "57d1c980-b6f4-4f7b-9cbe-9be88495d841", "name": "a302670d-46d5-4562-bd79-162909ef155a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8baa3ae2-948d-4504-8e5f-96544b5bff7d"}}}]}, {"uuid": "33892645-c73d-42da-9133-c45f150cfe05", "name": "load_p1rlv452_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb46f1ae-0cdb-45d1-b389-639cdf345f8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "57d1c980-b6f4-4f7b-9cbe-9be88495d841"}}}}, {"uuid": "99f3b56a-cb1e-43d1-bd43-4c73175033c1", "name": "cc4294ad-1de6-403b-b2b5-71056cc2f3fe_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2596055778412756, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4460523908595607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9b0b62d1-9bd0-450b-9454-3dae35c5bb13", "name": "66d2645b-5405-436b-a633-5b7d8b80ad2c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "99f3b56a-cb1e-43d1-bd43-4c73175033c1"}}}]}, {"uuid": "26f59976-54ab-440b-a03f-d9ddaecc9239", "name": "load_p1rlv453_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6a8a3c7-5165-48b7-8233-30d3af045442"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9b0b62d1-9bd0-450b-9454-3dae35c5bb13"}}}}, {"uuid": "7bcd775c-fb87-4ffd-be72-aa4957ceb9fc", "name": "e5e9ddd3-8c92-4393-8c95-8ff5ce52a467_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2596055778412756, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4460523908595607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "795c5ff0-765b-4d2e-84e6-b605b9f21f84", "name": "db356f00-6f24-406a-8f64-46b49003841a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7bcd775c-fb87-4ffd-be72-aa4957ceb9fc"}}}]}, {"uuid": "cd277a1a-45ef-4295-9a91-09ec9aec78d8", "name": "load_p1rlv453_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6a8a3c7-5165-48b7-8233-30d3af045442"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "795c5ff0-765b-4d2e-84e6-b605b9f21f84"}}}}, {"uuid": "af2dfd1e-d3d1-4abc-8e58-088d954abeb0", "name": "0c037c26-3125-41e7-8397-dae2b1fc74c8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4699462180170992, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3815978523472859, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bb461309-e0cf-4887-9031-9ac78ac63cb4", "name": "2b0e6d4f-78ed-4a16-b402-7009875520fe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "af2dfd1e-d3d1-4abc-8e58-088d954abeb0"}}}]}, {"uuid": "d51fe97e-f43a-4667-a760-d9a9eed3d4b7", "name": "load_p1rlv454_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3493b0ed-43a2-4602-a7ad-a817331c9d8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bb461309-e0cf-4887-9031-9ac78ac63cb4"}}}}, {"uuid": "5cad70c7-ac45-4b90-a5f3-78e154cc8341", "name": "dd000ba0-8605-43d7-8515-81e634f62533_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4699462180170992, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3815978523472859, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fc6fb7d6-1359-476d-97b1-20bd867f3a18", "name": "6598e321-ea38-42c7-a989-a50e7ae0ac62", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5cad70c7-ac45-4b90-a5f3-78e154cc8341"}}}]}, {"uuid": "215467aa-97f1-4ba5-8bcf-bad6a898e4f8", "name": "load_p1rlv454_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3493b0ed-43a2-4602-a7ad-a817331c9d8e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fc6fb7d6-1359-476d-97b1-20bd867f3a18"}}}}, {"uuid": "c1266b4d-e8a3-48a2-9297-e10fe963cf5e", "name": "29fc98bb-2656-41f5-ad5e-1431eb3fb30b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5202593896091736, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6973445820856009, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "96cd17e7-f798-45b1-8136-6e07bd96d687", "name": "2bbad14f-f795-44e7-8b67-3c821ac4df2b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c1266b4d-e8a3-48a2-9297-e10fe963cf5e"}}}]}, {"uuid": "f0320455-ed71-4eeb-b7cb-3891fd5c8df6", "name": "load_p1rlv455_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "552153cc-f5be-42ee-9985-9361c2e7e2a1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "96cd17e7-f798-45b1-8136-6e07bd96d687"}}}}, {"uuid": "4a5816d1-5d8a-4d59-9761-844ac1fca02d", "name": "de884caa-1c0a-4d92-9115-9f212e96e999_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5202593896091736, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6973445820856009, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "20c248bc-ee70-493f-abc6-aef541a4bb02", "name": "0837a3bd-373a-4210-b7ca-d37bd7aac7cd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4a5816d1-5d8a-4d59-9761-844ac1fca02d"}}}]}, {"uuid": "e503e50d-78e4-4333-bd39-09478619af1c", "name": "load_p1rlv455_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "552153cc-f5be-42ee-9985-9361c2e7e2a1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "20c248bc-ee70-493f-abc6-aef541a4bb02"}}}}, {"uuid": "6d04a185-16bf-47d6-9f92-deb00c1096f4", "name": "78026fdd-52f3-43d6-bb7e-c54fee37d7d9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.664483224984605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9538644530515166, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "704246ad-9aa3-4b64-8adc-72cdeefbf279", "name": "450c3cf4-a57c-4818-9ed7-c910ce08ddae", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6d04a185-16bf-47d6-9f92-deb00c1096f4"}}}]}, {"uuid": "04d7b81b-9fb7-418b-b8ae-51d232702c4d", "name": "load_p1rlv456_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85f0d94e-c096-4d53-ae05-f0dc59f73d02"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "704246ad-9aa3-4b64-8adc-72cdeefbf279"}}}}, {"uuid": "f8906971-5101-4f75-a721-5b7cc3867d5d", "name": "a6fbb3e3-65df-4eaf-8ea6-1ce7d4ce30c2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.664483224984605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9538644530515166, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bda896e9-bf5f-4151-aea7-4cb9f002a0f3", "name": "0305c1c2-bb42-495e-b37e-c56caa95ae85", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8906971-5101-4f75-a721-5b7cc3867d5d"}}}]}, {"uuid": "b3693e19-7baa-4575-ab10-58ea8a3303e5", "name": "load_p1rlv456_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85f0d94e-c096-4d53-ae05-f0dc59f73d02"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bda896e9-bf5f-4151-aea7-4cb9f002a0f3"}}}}, {"uuid": "07259dfc-789d-432d-b8a8-7201249a0d4a", "name": "f9e0814c-a28f-4273-af2f-71fc3f0ddb91_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.001928314210379, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4572901775510755, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8e28387d-892b-4c4a-9bfc-5d99ddc34b9d", "name": "5ade5781-13d3-48eb-92c9-b1b1b675db52", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "07259dfc-789d-432d-b8a8-7201249a0d4a"}}}]}, {"uuid": "6396f646-0b7b-4db8-905b-1aaa0fc529ac", "name": "load_p1rlv457_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6278f6ee-7332-4de8-9d2c-83bb637f489f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8e28387d-892b-4c4a-9bfc-5d99ddc34b9d"}}}}, {"uuid": "eef9909b-7dfb-4201-ba64-64972a7510b2", "name": "659fa35c-9f5f-4372-8a85-75793de72145_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.001928314210379, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4572901775510755, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f0beaee8-0dff-41be-8079-7008b9f38793", "name": "39099389-cdfc-4a1f-816c-c93dfa19271a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eef9909b-7dfb-4201-ba64-64972a7510b2"}}}]}, {"uuid": "cd573da9-d64f-4198-8f46-34a079f6602d", "name": "load_p1rlv457_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6278f6ee-7332-4de8-9d2c-83bb637f489f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f0beaee8-0dff-41be-8079-7008b9f38793"}}}}, {"uuid": "c788b54e-b76d-42bb-b55d-f9517ddd652b", "name": "fdfcd836-32ea-4c57-a20d-a8d0068a30d3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.24613321897865, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9528039237137753, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f06e3d1c-158f-416f-a682-7a7e66916b4c", "name": "2600ca77-2070-413e-9efb-f80804cb32fe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c788b54e-b76d-42bb-b55d-f9517ddd652b"}}}]}, {"uuid": "33524da1-876d-4466-9090-b54091e6186f", "name": "load_p1rlv458_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec66e302-748d-4300-ba65-719de0a906bb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f06e3d1c-158f-416f-a682-7a7e66916b4c"}}}}, {"uuid": "00b54568-a399-4168-b6b2-108bddace79b", "name": "3684c6ad-023a-42d3-be59-ed89bf121656_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.24613321897865, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9528039237137753, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2a2dfb4e-141c-4d8d-a7de-4dad5ba04eb7", "name": "05729729-e11a-4080-8e71-641b55183fda", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "00b54568-a399-4168-b6b2-108bddace79b"}}}]}, {"uuid": "c1a77fe8-1909-4bc7-ae97-94b06c52435b", "name": "load_p1rlv458_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec66e302-748d-4300-ba65-719de0a906bb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2a2dfb4e-141c-4d8d-a7de-4dad5ba04eb7"}}}}, {"uuid": "a03db4c5-93b6-4bd5-8db4-6a563dcdb30e", "name": "6aa860cd-622e-4014-af12-abc266d26b30_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.502751049099443, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7555421856436744, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ba26bf17-ab63-4273-a0bb-faf9bad4de4c", "name": "717ae0b6-4d1f-464a-a299-f077fbb35b0a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a03db4c5-93b6-4bd5-8db4-6a563dcdb30e"}}}]}, {"uuid": "f23ab323-54c8-435f-b1fd-8e60cf8cd52c", "name": "load_p1rlv459_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c112196-bcbc-41bc-99a9-f3657c335c7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ba26bf17-ab63-4273-a0bb-faf9bad4de4c"}}}}, {"uuid": "8ef17114-2bb3-45d9-841e-3bd09e0e7c5f", "name": "90727a7c-dec7-417b-b2f0-57aab2169b89_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.502751049099443, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7555421856436744, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3a502be6-0db3-4667-b815-6a8ee1a44e72", "name": "4a9ecb98-9a3c-4d9b-a503-5e0e697e9acd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ef17114-2bb3-45d9-841e-3bd09e0e7c5f"}}}]}, {"uuid": "f800f59e-b573-4dfb-8d51-8b8de0ced0be", "name": "load_p1rlv459_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c112196-bcbc-41bc-99a9-f3657c335c7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3a502be6-0db3-4667-b815-6a8ee1a44e72"}}}}, {"uuid": "e36a1032-84f7-47fb-99f7-ba68f0b1c98f", "name": "f9131d78-d7bf-409d-804a-fc58fdaac44d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8202631342288826, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.26720803692022926, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0cf0611e-cc09-4f7e-a2bd-4fd7c593d2f4", "name": "0e0565b4-bd83-4f37-81b9-95f041a12d3e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e36a1032-84f7-47fb-99f7-ba68f0b1c98f"}}}]}, {"uuid": "bb55e834-c0df-4bda-8242-dcccf3fe15eb", "name": "load_p1rlv460_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76b212f9-2e27-4064-a2c5-079786afb1d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0cf0611e-cc09-4f7e-a2bd-4fd7c593d2f4"}}}}, {"uuid": "2b4a72cb-bb3d-4bc4-bd92-709af163a462", "name": "928a7425-e29f-43af-abfa-86f7dc12bd20_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8202631342288826, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.26720803692022926, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "86cc4222-c03b-482f-90aa-46d44bb2aeef", "name": "9df527a7-87df-4771-bbfc-7d7d2a3f0eff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2b4a72cb-bb3d-4bc4-bd92-709af163a462"}}}]}, {"uuid": "3071b825-5459-4be8-8b76-f333c316f4c7", "name": "load_p1rlv460_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76b212f9-2e27-4064-a2c5-079786afb1d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "86cc4222-c03b-482f-90aa-46d44bb2aeef"}}}}, {"uuid": "1681dc0a-7a40-434e-8dba-1f19db51925a", "name": "bbe8984b-a62b-45d1-b9f7-12adcba1965e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4622944887503224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10483650830237357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5152946d-17ad-452a-8d50-3ab5b14d25ec", "name": "c3dc8d70-ae93-40ba-b524-b4d321e9f59f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1681dc0a-7a40-434e-8dba-1f19db51925a"}}}]}, {"uuid": "77243974-dd20-4014-b17d-913466af3faf", "name": "load_p1rlv461_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76dd0f1b-4109-4707-a547-f0ab1b6e148f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5152946d-17ad-452a-8d50-3ab5b14d25ec"}}}}, {"uuid": "7578199c-24c3-47ee-8412-ae5e4b092da4", "name": "5bdbdf12-504c-40f1-947d-aa28ee8f89ae_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4622944887503224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10483650830237357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1af4b0d4-e28b-424b-9db1-b7e5869961ab", "name": "6beb972c-9312-4ba8-be20-e79b4ada60e2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7578199c-24c3-47ee-8412-ae5e4b092da4"}}}]}, {"uuid": "a432c673-e52c-41e5-9676-f3fb7b3a04af", "name": "load_p1rlv461_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76dd0f1b-4109-4707-a547-f0ab1b6e148f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1af4b0d4-e28b-424b-9db1-b7e5869961ab"}}}}, {"uuid": "74ed2102-5079-49a3-961d-c854ee51c3cf", "name": "70864144-ffa6-4574-9ecc-4a5c7a3a4b29_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3786182488338723, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5359363058124609, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8b5d7657-81f0-47be-bf22-bebb1d57940b", "name": "caf9718a-fa65-4a51-9361-02be5286f5a6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "74ed2102-5079-49a3-961d-c854ee51c3cf"}}}]}, {"uuid": "f07a0d15-0adc-40e9-aa3c-e16810c2f41e", "name": "load_p1rlv462_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9176da24-7eb5-4b0b-99dd-886c3f974798"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8b5d7657-81f0-47be-bf22-bebb1d57940b"}}}}, {"uuid": "144dbe08-6967-4a00-8ff3-45902a02f650", "name": "8c97b50e-20d1-4d7f-9104-ac19c7d6d5c7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3786182488338723, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5359363058124609, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eb331271-5ef8-45ee-98a5-5e50fea9bb53", "name": "ead2c979-3975-4844-801f-17fa2f40abd4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "144dbe08-6967-4a00-8ff3-45902a02f650"}}}]}, {"uuid": "dbb406a5-e5db-4542-bab9-85656860b5cc", "name": "load_p1rlv462_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9176da24-7eb5-4b0b-99dd-886c3f974798"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eb331271-5ef8-45ee-98a5-5e50fea9bb53"}}}}, {"uuid": "c9b8b2db-fc98-4b73-9372-7b7f56fc06fd", "name": "d38aa64b-6817-4902-b4af-29d0405521ac_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.746284303820433, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6724067157838972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8affc3e7-cc33-47aa-8b64-46f8752acfd2", "name": "832568a2-1b70-43bd-b287-a8ecc7b6008e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9b8b2db-fc98-4b73-9372-7b7f56fc06fd"}}}]}, {"uuid": "bbb2b72b-01b7-4567-a526-08186d132dff", "name": "load_p1rlv463_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff9d9cca-1878-478d-a190-b58c9098f13e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8affc3e7-cc33-47aa-8b64-46f8752acfd2"}}}}, {"uuid": "8493882e-5fe4-4431-b91d-23f766fb3835", "name": "2b44ede7-f0d3-40cf-9ef5-3911382d78f7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.746284303820433, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6724067157838972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7f0a4bf9-4787-4faf-b94f-27e068b9fd23", "name": "ae16dc1f-98a8-471a-8950-fc2f7856f811", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8493882e-5fe4-4431-b91d-23f766fb3835"}}}]}, {"uuid": "0692a8dd-5767-4faa-8ed2-22f06e6818a5", "name": "load_p1rlv463_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff9d9cca-1878-478d-a190-b58c9098f13e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7f0a4bf9-4787-4faf-b94f-27e068b9fd23"}}}}, {"uuid": "90b9c581-1af5-4535-a4e6-5c0bb62f15cd", "name": "589c50c8-66ad-464a-b072-b39b7b629c8e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6697995975485909, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.41657408993223344, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bdff3310-45b0-4cd2-9fbb-76ac2646ed22", "name": "a584c625-4eaf-4447-a60f-da33dbd2aad3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "90b9c581-1af5-4535-a4e6-5c0bb62f15cd"}}}]}, {"uuid": "0ac20aca-a1b8-4ca7-8af5-c18603f14c87", "name": "load_p1rlv464_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "895d0235-3ee6-4f06-9978-9d615d721ebd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bdff3310-45b0-4cd2-9fbb-76ac2646ed22"}}}}, {"uuid": "045e93db-d4b2-4939-8648-121b125682a9", "name": "78c10fdf-2c51-4a7e-b931-5f4249b795a5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6697995975485909, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.41657408993223344, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1836608f-4a1a-4787-a25b-a3e6d90cf0fb", "name": "40119705-7971-4e0c-9403-92879dc6f264", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "045e93db-d4b2-4939-8648-121b125682a9"}}}]}, {"uuid": "70712bd9-cf0d-4d57-b077-5f8c62d2c443", "name": "load_p1rlv464_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "895d0235-3ee6-4f06-9978-9d615d721ebd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1836608f-4a1a-4787-a25b-a3e6d90cf0fb"}}}}, {"uuid": "23f7b572-b420-4566-a98c-b0957a8d3705", "name": "5540f6f1-1e88-429e-8a19-7fbed822563b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.39658717665728, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7677987041236869, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "231541f9-de2a-43fe-8f6d-b1fa16116d70", "name": "68e7af5f-ee63-47a5-9fbc-85802e26b14b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "23f7b572-b420-4566-a98c-b0957a8d3705"}}}]}, {"uuid": "4dbb057b-7a4c-46b0-b651-b7953221ee68", "name": "load_p1rlv474_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e589527-d388-4364-87d2-2f4af1a14509"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "231541f9-de2a-43fe-8f6d-b1fa16116d70"}}}}, {"uuid": "a1f1dbc9-434a-4bda-a3be-744652481039", "name": "c1626b19-390a-438b-bb22-3a67618e84e3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.39658717665728, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7677987041236869, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e05045f9-527b-4c22-b442-7e07341cff95", "name": "16229ae1-0f2c-49a1-b497-ecb55f58586d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a1f1dbc9-434a-4bda-a3be-744652481039"}}}]}, {"uuid": "a2b46400-933c-4daf-8d8a-0db79c8d68c8", "name": "load_p1rlv474_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e589527-d388-4364-87d2-2f4af1a14509"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e05045f9-527b-4c22-b442-7e07341cff95"}}}}, {"uuid": "abf3daaf-3351-4985-aa87-859e07d1038e", "name": "3aa690da-241d-46f3-bb64-0117330bb2c2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0286208645240644, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.052486030755511705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "55898de9-b406-4e16-9444-fc188a12b038", "name": "a5533b53-cc31-4481-93a7-e7a1a2fe8c05", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "abf3daaf-3351-4985-aa87-859e07d1038e"}}}]}, {"uuid": "043b62da-c1eb-4c2e-98d3-267b9c8c764c", "name": "load_p1rlv480_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb55ec0b-b6f7-48a7-8dae-dda95fc34499"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "55898de9-b406-4e16-9444-fc188a12b038"}}}}, {"uuid": "fb39a764-5af3-48da-9038-0a882971a76f", "name": "ae6d6173-39cd-4f95-a615-43c904298ad5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0286208645240644, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.052486030755511705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d268605c-e163-4f4e-a55d-89769662b069", "name": "1ce324fd-d025-41ff-b7a3-c63373a72816", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fb39a764-5af3-48da-9038-0a882971a76f"}}}]}, {"uuid": "f055d64c-5f91-48e8-a3a0-3e00176d588a", "name": "load_p1rlv480_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb55ec0b-b6f7-48a7-8dae-dda95fc34499"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d268605c-e163-4f4e-a55d-89769662b069"}}}}, {"uuid": "01d86a82-6b19-4195-af70-50b97e15278b", "name": "0ce8fcdc-7ce8-4c03-8425-b80a2e092b64_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.344060161619426, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2705527109429713, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "084a4884-2c0f-4fc8-9f28-9ef621e2d7db", "name": "df7e8996-7993-4e74-86f4-57f32eec8344", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "01d86a82-6b19-4195-af70-50b97e15278b"}}}]}, {"uuid": "9d37f739-515f-41ac-95e3-b2c68f6180f2", "name": "load_p1rlv481_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d9e77ad-42c6-4413-96e6-debfed3c442a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "084a4884-2c0f-4fc8-9f28-9ef621e2d7db"}}}}, {"uuid": "55980176-93de-43e5-b013-471374eb1320", "name": "635de8d9-6a09-4e38-b23f-1f821810a8c3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.344060161619426, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2705527109429713, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4ff8aadf-bf74-4264-afc9-654c2b1a74d2", "name": "0a1e8ade-aee1-422e-8547-341980381f49", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "55980176-93de-43e5-b013-471374eb1320"}}}]}, {"uuid": "f6153836-4bed-404c-bdf1-63eb9f24e1f9", "name": "load_p1rlv481_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d9e77ad-42c6-4413-96e6-debfed3c442a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4ff8aadf-bf74-4264-afc9-654c2b1a74d2"}}}}, {"uuid": "aa79d731-94a7-48dd-8d59-5d7e0353e921", "name": "f68c64e8-6ce9-4752-b6f1-f633305cc042_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7771517670040275, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8838563298920215, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "346e1f94-ef53-4328-85d8-3e731cbed0bc", "name": "b543513b-8bbd-4ee6-af00-6b2c45657b65", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aa79d731-94a7-48dd-8d59-5d7e0353e921"}}}]}, {"uuid": "5330f48f-076b-49f1-82a8-aa95d814afc0", "name": "load_p1rlv482_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d4b708f-cc15-4ee3-87e0-4d26fec02f1e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "346e1f94-ef53-4328-85d8-3e731cbed0bc"}}}}, {"uuid": "fa809bda-ab1f-468c-a1c0-00ae4155b327", "name": "1df30ee9-3d2f-4c8e-b8f7-1c8c8560c726_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7771517670040275, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8838563298920215, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "61d43de4-349e-45e0-9fad-ca8b5cb8a96b", "name": "222bd2f6-8ef5-451f-99d4-e12b6a9b7b18", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fa809bda-ab1f-468c-a1c0-00ae4155b327"}}}]}, {"uuid": "d784bc94-505d-48cc-9eb3-5d431ef40017", "name": "load_p1rlv482_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d4b708f-cc15-4ee3-87e0-4d26fec02f1e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "61d43de4-349e-45e0-9fad-ca8b5cb8a96b"}}}}, {"uuid": "1825ac5b-af7c-47f2-9768-71fb16fe3580", "name": "7e3d9b34-b59b-4b5f-80c0-4b6df9e76ec6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.028781788264419, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6709073147144231, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "75baf9e4-7868-4e67-b246-614b1840a719", "name": "1027a59c-2df8-4068-94f2-2a7dce473b00", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1825ac5b-af7c-47f2-9768-71fb16fe3580"}}}]}, {"uuid": "5f58554e-ae27-4ee3-b8ce-2ce2b4da05e1", "name": "load_p1rlv483_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d059a618-6f09-404b-b1a0-0e7aa0c55c45"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "75baf9e4-7868-4e67-b246-614b1840a719"}}}}, {"uuid": "3bc1d7e1-1784-42d6-8c39-e8e06455df71", "name": "4a61aa61-fe56-4b0f-9a5f-2f33c303efd8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.028781788264419, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6709073147144231, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f0079fd6-6054-417f-8616-d1e9750b4fae", "name": "b2202614-2c1e-42be-9eda-0fc84316a583", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3bc1d7e1-1784-42d6-8c39-e8e06455df71"}}}]}, {"uuid": "9a558047-9b01-41d0-848f-110b5dc5a875", "name": "load_p1rlv483_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d059a618-6f09-404b-b1a0-0e7aa0c55c45"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f0079fd6-6054-417f-8616-d1e9750b4fae"}}}}, {"uuid": "7fd86059-1fb0-4850-8383-80f9c0d89b07", "name": "78b7cde0-9788-4784-bda5-b2e87c3762ce_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2cae686a-7690-4c89-87fb-f6411445c88a", "name": "4b8f45ca-515d-4011-beb3-1d7dff9174f4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7fd86059-1fb0-4850-8383-80f9c0d89b07"}}}]}, {"uuid": "0a5c43a0-66a6-47dc-a6a2-81c017f57312", "name": "load_p1rlv484_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fde62b60-c5f6-44d6-b2f2-211c21b02033"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2cae686a-7690-4c89-87fb-f6411445c88a"}}}}, {"uuid": "91f21c3a-09a1-463e-bd18-697a4cef3d1d", "name": "cae84f22-cbc8-4490-87ec-65a09cce4be7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.582589254943593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7543832500215285, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c22693f2-4e3e-4332-90df-348f8224e354", "name": "ed9ef4a6-f1f0-4298-a291-139014d1ed1b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "91f21c3a-09a1-463e-bd18-697a4cef3d1d"}}}]}, {"uuid": "2efcaf50-890a-472b-8585-0b0aed28c88c", "name": "load_p1rlv484_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fde62b60-c5f6-44d6-b2f2-211c21b02033"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c22693f2-4e3e-4332-90df-348f8224e354"}}}}, {"uuid": "7c82752e-6238-4694-b6fc-1de01350b614", "name": "0a2fdbf3-b2e1-4e28-bda9-b206aeef6354_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1427818095792333, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033588044558321, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bede68a2-9953-41f7-81c5-67e173e1f7b5", "name": "b81a309e-cfd3-495d-8bc6-b8876ab86522", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7c82752e-6238-4694-b6fc-1de01350b614"}}}]}, {"uuid": "961d3415-4d1b-469d-ad95-d2fb2cba8f9f", "name": "load_p1rlv485_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d2c379-7e19-46c4-8c6e-533fa9db7764"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bede68a2-9953-41f7-81c5-67e173e1f7b5"}}}}, {"uuid": "c9782cba-ea23-4cc0-8eeb-ab8863e342d1", "name": "e23f1faf-8f46-47c3-9fcb-ecf840026784_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1427818095792333, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033588044558321, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2cbeff2f-e022-4b7d-84c0-a0669e5273fc", "name": "15584f6e-d34b-4bab-a9b2-27de606bf26a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9782cba-ea23-4cc0-8eeb-ab8863e342d1"}}}]}, {"uuid": "71f48568-c9c7-48f3-b31a-c98da55e2867", "name": "load_p1rlv485_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d2c379-7e19-46c4-8c6e-533fa9db7764"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2cbeff2f-e022-4b7d-84c0-a0669e5273fc"}}}}, {"uuid": "ef005c11-6613-4d1f-a3f9-ef1660f354cc", "name": "8574ce8c-c0ac-458f-b3d1-5d56ab2dfd00_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5348201699646123, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21241824123648728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f345581f-8b31-49e3-b909-744fd85f1da8", "name": "2583cce9-86fe-4153-b471-f6f480cd262f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ef005c11-6613-4d1f-a3f9-ef1660f354cc"}}}]}, {"uuid": "d781c621-8a08-4bd9-8932-b022ced80680", "name": "load_p1rlv486_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a54b2228-9e7d-4e6b-939d-ab2765454522"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f345581f-8b31-49e3-b909-744fd85f1da8"}}}}, {"uuid": "8b485a7f-3820-452a-ad3a-dbf638044106", "name": "f82bda5c-6bd7-457a-bd8d-5a3d236abcc9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5348201699646123, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21241824123648728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eb877549-0aa6-41ab-a159-3eb8f8a8d16e", "name": "7ec9eede-273c-464c-8684-5216cab393e3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8b485a7f-3820-452a-ad3a-dbf638044106"}}}]}, {"uuid": "7c85c75e-9c64-411f-b5f6-fc3e067e7dad", "name": "load_p1rlv486_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a54b2228-9e7d-4e6b-939d-ab2765454522"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eb877549-0aa6-41ab-a159-3eb8f8a8d16e"}}}}, {"uuid": "37587ae2-c7e3-4b8e-bc53-2e1bd69f1b94", "name": "dbb8d51a-9d04-47a0-8808-9d984c3f20b9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.735884899619907, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7862059386133167, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2a04339c-e49e-4079-8dfa-72d503319bb3", "name": "ed24707c-33ab-4e77-a007-3fc31e829c35", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "37587ae2-c7e3-4b8e-bc53-2e1bd69f1b94"}}}]}, {"uuid": "caa60bdc-63e7-41df-9f56-3480e49958e3", "name": "load_p1rlv487_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2d5799-907e-46fd-a389-120aea352775"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2a04339c-e49e-4079-8dfa-72d503319bb3"}}}}, {"uuid": "635823f5-2af2-4722-8628-1c8309c068f0", "name": "53db1c7b-b1ea-4eda-804a-4739b66213c7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.735884899619907, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7862059386133167, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "785d5de7-2553-4f05-8d72-6e79c2b533a0", "name": "de29166c-4d19-4cc6-a3ba-2cfc74254d6d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "635823f5-2af2-4722-8628-1c8309c068f0"}}}]}, {"uuid": "492910aa-850c-43d9-8fd0-a8b444dd4d33", "name": "load_p1rlv487_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2d5799-907e-46fd-a389-120aea352775"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "785d5de7-2553-4f05-8d72-6e79c2b533a0"}}}}, {"uuid": "114a88fc-4cce-4a85-8877-b8af701eb28b", "name": "f66e6768-368c-4b9a-93d1-5bfa67109daa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4382677398578904, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21115535117680156, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "15e403be-c270-4b31-b9ee-89554f382fd3", "name": "3905f176-648c-47db-9614-82224653a856", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "114a88fc-4cce-4a85-8877-b8af701eb28b"}}}]}, {"uuid": "119a4e4a-f6be-4b55-9900-87c023e626f3", "name": "load_p1rlv523_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97c38794-7c60-4ff8-b09b-7503c9604409"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "15e403be-c270-4b31-b9ee-89554f382fd3"}}}}, {"uuid": "494fd173-51a7-443c-8d92-b653a872f414", "name": "343b7015-d5e0-4d33-9063-52885cdf5728_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4382677398578904, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21115535117680156, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c61863b-4b03-449a-ba74-5a0b3b6f1240", "name": "517586d4-15d7-438c-865e-10fa3790e5ad", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "494fd173-51a7-443c-8d92-b653a872f414"}}}]}, {"uuid": "42101e58-1bef-43a2-8cf3-8b619ff04974", "name": "load_p1rlv523_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97c38794-7c60-4ff8-b09b-7503c9604409"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c61863b-4b03-449a-ba74-5a0b3b6f1240"}}}}, {"uuid": "44f33879-a83f-42d3-b0fd-b054eebfa36c", "name": "d5a8bbba-4bf9-4548-b809-990af5652257_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0716401691896973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6949594139700135, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b670fe47-e049-4a45-bd32-37a9bddc3c4a", "name": "c20e5090-9efa-4101-9164-97e4f547dc7b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "44f33879-a83f-42d3-b0fd-b054eebfa36c"}}}]}, {"uuid": "023c8818-27f6-42ae-a0a0-75b5b12371d4", "name": "load_p1rlv524_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bef074be-aac4-4d82-a832-641729756802"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b670fe47-e049-4a45-bd32-37a9bddc3c4a"}}}}, {"uuid": "3eaf7dfa-6b10-49c8-9220-412dd0c53f54", "name": "b174c88c-0b68-4811-a183-e2455e7deccd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0716401691896973, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6949594139700135, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7dd02363-2c3f-4a2d-b42a-cf75c83efe12", "name": "babb8a4d-c0a4-4183-bfb7-5f5a6f2d9682", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3eaf7dfa-6b10-49c8-9220-412dd0c53f54"}}}]}, {"uuid": "7490587f-d2a9-4d03-b135-bf1f15912727", "name": "load_p1rlv524_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bef074be-aac4-4d82-a832-641729756802"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7dd02363-2c3f-4a2d-b42a-cf75c83efe12"}}}}, {"uuid": "0daa0bde-626f-4c61-91dc-fd9fcbd0228f", "name": "59d87379-9909-4561-9fe0-803c1cc97921_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6848010607962993, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6615616037111118, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "668bb1d4-8d20-4fc2-b12a-c853b2093b6c", "name": "ef894c10-fdff-4acf-8a4f-28340bd89565", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0daa0bde-626f-4c61-91dc-fd9fcbd0228f"}}}]}, {"uuid": "89affe1d-df30-4472-aa79-d9d41a960af9", "name": "load_p1rlv525_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a42f8b99-82c6-4c90-81ea-6ccb38eacfab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "668bb1d4-8d20-4fc2-b12a-c853b2093b6c"}}}}, {"uuid": "eceeb9ce-cae8-464e-a1dd-f974d4982328", "name": "da7affbb-c986-4a59-aebe-0921c814e735_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6848010607962993, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6615616037111118, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "827c6e55-1c05-4aec-977d-63675c508fce", "name": "0c6e6671-1359-4d87-912d-0245395bea05", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eceeb9ce-cae8-464e-a1dd-f974d4982328"}}}]}, {"uuid": "565dc000-ec57-49d2-b399-cdc496915202", "name": "load_p1rlv525_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a42f8b99-82c6-4c90-81ea-6ccb38eacfab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "827c6e55-1c05-4aec-977d-63675c508fce"}}}}, {"uuid": "6fce8211-ec65-4b35-b79a-3e48952231d3", "name": "3c91c04b-92ea-45f7-9066-7c4023db5805_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9444657359992037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.058006608995704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4c12a34f-4cc3-44ff-b6a1-a2d2e06a2d01", "name": "5e5d11ea-47a7-4336-913a-e6e84156ba69", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6fce8211-ec65-4b35-b79a-3e48952231d3"}}}]}, {"uuid": "702b22c3-6391-4c00-b2a0-213473b1de53", "name": "load_p1rlv526_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ab8e220-faf9-4108-80f8-22d2fe326c3d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4c12a34f-4cc3-44ff-b6a1-a2d2e06a2d01"}}}}, {"uuid": "8612b553-2a6f-4eb5-95d6-19616c0c0001", "name": "1eac6aa3-3aa4-4f02-9e94-8b3f243b0661_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9444657359992037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.058006608995704, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d30d2b5d-97a4-4bcd-8926-9437ae9121e2", "name": "2d8fbce5-1be7-41ca-87ed-b35b6f047dba", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8612b553-2a6f-4eb5-95d6-19616c0c0001"}}}]}, {"uuid": "f25a304e-9871-4686-8346-4e54947de4a3", "name": "load_p1rlv526_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ab8e220-faf9-4108-80f8-22d2fe326c3d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d30d2b5d-97a4-4bcd-8926-9437ae9121e2"}}}}, {"uuid": "c4adf770-4bf0-4ff9-b5e8-a2c0b0b0ed8f", "name": "59be0bf8-dd2b-4ee8-86ff-94aae3288264_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6722127407962883, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033140171384262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a6bdab56-e0b0-4621-8573-17afc2217e60", "name": "72ac885e-4a24-491b-bc5f-2df60f7c5985", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c4adf770-4bf0-4ff9-b5e8-a2c0b0b0ed8f"}}}]}, {"uuid": "1f909f54-5f67-4499-805b-268740afd001", "name": "load_p1rlv531_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32a1d9d7-31c7-4def-88d4-e4d41bd21572"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a6bdab56-e0b0-4621-8573-17afc2217e60"}}}}, {"uuid": "d0306536-ef63-46b5-8ad7-b0c2012c02ce", "name": "e6f65fcf-9b46-4b85-b626-363e8e3abf2c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6722127407962883, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033140171384262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a5029a49-6811-4590-9b37-08466159575e", "name": "8ba2dbc3-975d-4a74-9ad2-aab7450cacc3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d0306536-ef63-46b5-8ad7-b0c2012c02ce"}}}]}, {"uuid": "d29693fc-93cc-4dcb-a81e-ec915a22a887", "name": "load_p1rlv531_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32a1d9d7-31c7-4def-88d4-e4d41bd21572"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a5029a49-6811-4590-9b37-08466159575e"}}}}, {"uuid": "ff1ce328-5ff0-4a6a-8cc3-720b36e308db", "name": "3901e228-d7d3-4c2b-9623-61fcdd03d1d2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.813063869628266, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3555509200852155, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aa62e060-7c3f-4658-a5bb-6ac27d8eab7e", "name": "df21c81a-f687-4bfe-9a36-e095194a10cf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ff1ce328-5ff0-4a6a-8cc3-720b36e308db"}}}]}, {"uuid": "1bf2ee86-4b3a-4a51-bd37-3c02cc5b2eb2", "name": "load_p1rlv532_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1362feeb-2e2c-4dd1-9f49-239c952c6120"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aa62e060-7c3f-4658-a5bb-6ac27d8eab7e"}}}}, {"uuid": "2d4d05d7-da58-4665-ad42-9d5aaf1c1cc8", "name": "c15b620e-3633-49f2-946b-5e9f3ff7ee89_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.813063869628266, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3555509200852155, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f2a566e1-d88c-4f40-93e4-eb51f9da04d1", "name": "99fd0bef-ba99-4d29-ab3f-d0833baaa501", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2d4d05d7-da58-4665-ad42-9d5aaf1c1cc8"}}}]}, {"uuid": "4bbb646b-f5e5-434a-9150-ae55074d0217", "name": "load_p1rlv532_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1362feeb-2e2c-4dd1-9f49-239c952c6120"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f2a566e1-d88c-4f40-93e4-eb51f9da04d1"}}}}, {"uuid": "d10892f4-2562-4589-abbb-e58c3bbbdbe5", "name": "9dcb1517-15a2-4fcd-949e-c7735a62b8eb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.789788128831495, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 5.104197877675544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d15b6add-9538-4b27-8b4f-eebe82806984", "name": "67e36378-dce1-4fd2-9824-8f9da766bd2c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d10892f4-2562-4589-abbb-e58c3bbbdbe5"}}}]}, {"uuid": "ad822df3-0d76-4929-945d-38f5589067a4", "name": "load_p1rlv533_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f79bc5f-375f-4ecd-b828-eb7b137d7cab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d15b6add-9538-4b27-8b4f-eebe82806984"}}}}, {"uuid": "ae02b387-1fd5-4a79-8eed-9a740d62b494", "name": "4823141d-b517-4d47-9c11-5a9d94ba773f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.789788128831495, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 5.104197877675544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "99541b60-fd2b-4302-bed5-43ba04e59d08", "name": "8099a6a3-dd55-4a38-a314-51295e3bfa2a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ae02b387-1fd5-4a79-8eed-9a740d62b494"}}}]}, {"uuid": "c2badedc-6ebd-477c-9ff0-9d83cd96671f", "name": "load_p1rlv533_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f79bc5f-375f-4ecd-b828-eb7b137d7cab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "99541b60-fd2b-4302-bed5-43ba04e59d08"}}}}, {"uuid": "6fd8c910-05ab-4e2e-96ca-a0bf62a01f30", "name": "8d91e304-d583-4a4b-862e-370c05d9fbe4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.504585200899067, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1614896338945686, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "90ff893c-5696-4cba-a481-4a0bb14f3407", "name": "ae047cdb-aeef-4a48-a4c9-b5f1e0c2c7c3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6fd8c910-05ab-4e2e-96ca-a0bf62a01f30"}}}]}, {"uuid": "43ed6dc8-dc77-4444-bf68-f73ff89a3407", "name": "load_p1rlv534_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0eb7074c-0745-4089-9329-aa3495f9b460"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "90ff893c-5696-4cba-a481-4a0bb14f3407"}}}}, {"uuid": "cedc9d19-d4d6-4694-a37c-887b76cad22f", "name": "9064d56b-453f-427f-98e9-e6bbff3cbfc1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.504585200899067, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1614896338945686, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3a43066d-745a-46de-982f-db83487f1a5f", "name": "d5034cec-1823-4361-8099-fa7676d8340e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cedc9d19-d4d6-4694-a37c-887b76cad22f"}}}]}, {"uuid": "d6d0bf46-ec50-4d26-b2d2-9fbf24a065cb", "name": "load_p1rlv534_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0eb7074c-0745-4089-9329-aa3495f9b460"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3a43066d-745a-46de-982f-db83487f1a5f"}}}}, {"uuid": "8eb73e5a-26ba-49e3-87b4-22016ac4eb9d", "name": "12013ea5-b812-4b9b-ad08-995006bf8ba9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.469077677978515, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3943727551399522, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b5b64d97-745a-4e70-b8d7-dce5eb3aadfc", "name": "ae3f01dd-2c40-41ef-bdf2-e9af34d6c3e7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8eb73e5a-26ba-49e3-87b4-22016ac4eb9d"}}}]}, {"uuid": "5a3c7273-5a95-4fd9-9e3a-4abfb773fbd2", "name": "load_p1rlv535_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9cc91945-564c-4ace-bb53-77150b107b41"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b5b64d97-745a-4e70-b8d7-dce5eb3aadfc"}}}}, {"uuid": "315291bc-784c-4b13-8505-fd4e1186ae77", "name": "9a714b62-4a2c-4c1d-97c4-7b429b3fffa9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.469077677978515, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3943727551399522, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eaa12b68-16e4-4231-8b3c-10991027b469", "name": "544f1730-6a8c-4030-83ff-11bc4f5f839f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "315291bc-784c-4b13-8505-fd4e1186ae77"}}}]}, {"uuid": "c7984dc5-3d90-44ff-9829-6ac742cd1eed", "name": "load_p1rlv535_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9cc91945-564c-4ace-bb53-77150b107b41"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eaa12b68-16e4-4231-8b3c-10991027b469"}}}}, {"uuid": "a6ace854-9e20-4e34-a8ac-01f0302fcf6d", "name": "43c90ffd-1e6d-4ea6-aada-9d1a91bf8efe_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.363394523648868, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.5065914416455906, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "065f8d03-acd9-4aef-bf32-ec679cb85d63", "name": "a3ed8f2e-1670-44f9-8eae-31627a7f6e4b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a6ace854-9e20-4e34-a8ac-01f0302fcf6d"}}}]}, {"uuid": "0255150b-1a31-4522-8e00-e52cf5303f41", "name": "load_p1rlv536_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2ea78a8-b9c5-4760-b153-51b45565069e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "065f8d03-acd9-4aef-bf32-ec679cb85d63"}}}}, {"uuid": "5c656de1-ba9d-489b-ae10-b9b2cc439b5b", "name": "7e21c187-648b-45f5-8192-47fa6cd85fdf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.363394523648868, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.5065914416455906, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9103a65d-75a8-4b3c-b9ff-c75118cc02df", "name": "daf7cc08-4973-45f6-9c31-f9245ec99d6f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5c656de1-ba9d-489b-ae10-b9b2cc439b5b"}}}]}, {"uuid": "c2ee4201-1d4a-4e30-aacf-9278043885fc", "name": "load_p1rlv536_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2ea78a8-b9c5-4760-b153-51b45565069e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9103a65d-75a8-4b3c-b9ff-c75118cc02df"}}}}, {"uuid": "0ca2ed02-9ad9-4b9d-9119-90d61a8f442c", "name": "d67ef7d5-94b0-4f8e-ab83-8624470c1e4e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.116603176693932, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3416039415731394, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e5767b74-2bf6-4ae0-acb8-f7db26c54e9d", "name": "fb42b4a2-841e-4022-a801-c14a2c0472a3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0ca2ed02-9ad9-4b9d-9119-90d61a8f442c"}}}]}, {"uuid": "72b2862e-3870-432b-ace8-81c712ed9d0d", "name": "load_p1rlv537_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9f2dfc9e-0b72-4465-b46a-d4e2a7a08f64"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e5767b74-2bf6-4ae0-acb8-f7db26c54e9d"}}}}, {"uuid": "23162cba-e334-4c24-8a3d-fe1db1c34086", "name": "9c924ee9-38fd-4520-9b2c-6cb755f2ff7e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.116603176693932, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3416039415731394, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "887a9b49-4c57-496a-900a-ca04d7b633c4", "name": "e54f1c45-bd2d-438b-8427-ecfd4fe61f5f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "23162cba-e334-4c24-8a3d-fe1db1c34086"}}}]}, {"uuid": "cc0d6925-8787-4d18-8616-fbf30f6c7a5a", "name": "load_p1rlv537_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9f2dfc9e-0b72-4465-b46a-d4e2a7a08f64"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "887a9b49-4c57-496a-900a-ca04d7b633c4"}}}}, {"uuid": "f479d563-a28f-487c-aba5-5b707ed429ad", "name": "ca60cbb9-048c-4e48-890a-7f6fbbe22e57_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6767459289154356, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5300288174067083, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "15daf489-d6f4-44b4-8486-5ef3e50832ad", "name": "0e758f65-c58a-4d6f-8f86-94670c97cafc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f479d563-a28f-487c-aba5-5b707ed429ad"}}}]}, {"uuid": "439e259e-fd7b-4f6b-87d9-7e0edc642f0a", "name": "load_p1rlv588_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75628d41-a82d-4425-8aa2-9f377c771a4c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "15daf489-d6f4-44b4-8486-5ef3e50832ad"}}}}, {"uuid": "0fbd767f-ece8-4ab5-ac8f-0e3782a2ad01", "name": "24e1c251-d056-4a30-bc82-aa0495716368_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6767459289154356, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5300288174067083, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a3aa04d-8ef0-49a2-ae2e-c077b3917d37", "name": "94f5cf50-5df4-4976-a4e9-e867721ce02b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0fbd767f-ece8-4ab5-ac8f-0e3782a2ad01"}}}]}, {"uuid": "3273b0f0-7ce3-4acf-ac66-549e19fb080b", "name": "load_p1rlv588_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75628d41-a82d-4425-8aa2-9f377c771a4c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0a3aa04d-8ef0-49a2-ae2e-c077b3917d37"}}}}, {"uuid": "5454428d-4b56-4c90-907c-d2e9f84a7cfd", "name": "c60191c3-09f3-420e-8bb1-27609dba5428_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8288850538480296, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31695217299610473, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "656c4d3a-9a01-4536-a830-009e8a1c604a", "name": "49d4c517-8c33-4849-91f9-ddd6d490ca31", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5454428d-4b56-4c90-907c-d2e9f84a7cfd"}}}]}, {"uuid": "6c13ec2c-acf6-4759-8425-ea576533c0dc", "name": "load_p1rlv589_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a1c60be-f1a1-48d6-b396-4cca6d8c4e62"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "656c4d3a-9a01-4536-a830-009e8a1c604a"}}}}, {"uuid": "ec435995-213c-4d1e-9b6b-df574871d42d", "name": "40b103c5-1c82-4aee-970a-e97519bb40a7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8288850538480296, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31695217299610473, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "faf98a77-df0a-477b-9f0f-6c363b5d2123", "name": "d7863b9b-b520-4877-b8bb-f9ef347b1395", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ec435995-213c-4d1e-9b6b-df574871d42d"}}}]}, {"uuid": "5c7d4191-8a3a-41c7-96f9-0bf89787fb72", "name": "load_p1rlv589_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a1c60be-f1a1-48d6-b396-4cca6d8c4e62"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "faf98a77-df0a-477b-9f0f-6c363b5d2123"}}}}, {"uuid": "3beaa7fe-e44e-44c0-8550-d2dae7715ac7", "name": "790e25fc-e449-4b27-ac54-1c45374122f5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.696455257947775, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.26943121901999684, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9a4ea290-c792-4ca9-8131-861a4fe68281", "name": "7302f3af-6f22-4f34-8c25-ece13254bfd8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3beaa7fe-e44e-44c0-8550-d2dae7715ac7"}}}]}, {"uuid": "7af173ca-da42-4ca5-b075-bdda3d3b89b8", "name": "load_p1rlv590_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81ce208e-7244-418a-9867-b55b95ba0716"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9a4ea290-c792-4ca9-8131-861a4fe68281"}}}}, {"uuid": "a849ebcb-fdce-4c2e-9923-7e6dd4671f26", "name": "aa41234b-e5d6-46df-bfa3-f936d97f3b39_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.696455257947775, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.26943121901999684, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "63e9d6da-3858-4395-859b-5e91c85df054", "name": "2aba41cc-ff74-4ae2-8f3c-83d6584d1cdc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a849ebcb-fdce-4c2e-9923-7e6dd4671f26"}}}]}, {"uuid": "8821a99d-8519-45d6-8371-606244795fe4", "name": "load_p1rlv590_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81ce208e-7244-418a-9867-b55b95ba0716"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "63e9d6da-3858-4395-859b-5e91c85df054"}}}}, {"uuid": "e23c6472-6af6-4c1e-932d-82123696e1c7", "name": "9f2ff2ae-cb4c-4205-874f-eb54aa1f32c9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.201469129926609, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0819349187657892, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6ed963ec-d8f3-47a6-b9ef-1624186b18da", "name": "ed5a8730-72c7-42e7-accc-d7028a2d3820", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e23c6472-6af6-4c1e-932d-82123696e1c7"}}}]}, {"uuid": "cbc47274-6a9a-4433-b62e-9b0e76aa835d", "name": "load_p1rlv657_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e58890e-e6ce-4dda-91c0-5ccfdb5c420d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6ed963ec-d8f3-47a6-b9ef-1624186b18da"}}}}, {"uuid": "65b73121-cc40-40d2-bddb-6b806f9c9c6d", "name": "eb47a207-eec2-4443-8388-f1644c875527_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.201469129926609, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0819349187657892, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d759b4b2-abec-4247-9cdb-3a0eafa5c792", "name": "d19accf4-becc-4df4-b130-93ba848b0f46", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "65b73121-cc40-40d2-bddb-6b806f9c9c6d"}}}]}, {"uuid": "abab5b2f-4b1c-487f-9c44-2e6d023e44f8", "name": "load_p1rlv657_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e58890e-e6ce-4dda-91c0-5ccfdb5c420d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d759b4b2-abec-4247-9cdb-3a0eafa5c792"}}}}, {"uuid": "0adb4448-1fc9-4ca0-aaab-5784dc663298", "name": "03cf9e18-143d-46fa-b23a-2636cc112a71_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1427818095792333, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033588044558321, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7ecc59f0-062e-4ed5-8351-d96ea59cb8f0", "name": "2961c013-da08-4474-ac53-1bd736e3b497", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0adb4448-1fc9-4ca0-aaab-5784dc663298"}}}]}, {"uuid": "997296ac-dae1-4e24-91df-20a54b89fd04", "name": "load_p1rlv660_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15751ee2-6783-472f-ad57-ec978234fec4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7ecc59f0-062e-4ed5-8351-d96ea59cb8f0"}}}}, {"uuid": "930ffc53-d75a-41a4-8954-7b674d2f4af9", "name": "107ff0d1-7f72-41fb-ae12-5f0d4767108e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1427818095792333, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5033588044558321, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "67c3a1d4-fc5a-4a0c-8e6e-b8450ea2d0db", "name": "25c8bf86-cc0a-427c-9964-cf4625f8a763", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "930ffc53-d75a-41a4-8954-7b674d2f4af9"}}}]}, {"uuid": "acb5b681-5b80-45dc-b349-c71b951c0130", "name": "load_p1rlv660_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15751ee2-6783-472f-ad57-ec978234fec4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "67c3a1d4-fc5a-4a0c-8e6e-b8450ea2d0db"}}}}, {"uuid": "73e32d34-7add-44a2-ad8b-44f65d59b253", "name": "78b53566-5bcd-4798-971c-7e9eda98137f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7935386970404408, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "353c28a6-2d33-4062-9cb5-cdaa5812041f", "name": "7868a77f-5078-42de-8c51-9bfb7ac7066e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "73e32d34-7add-44a2-ad8b-44f65d59b253"}}}]}, {"uuid": "00ee95d8-2b16-4183-adf1-e90910dbd1d1", "name": "load_p1rlv672_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb25bf05-ce7f-405a-8c17-fd166748f7d3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "353c28a6-2d33-4062-9cb5-cdaa5812041f"}}}}, {"uuid": "454c48ee-7a4d-4380-8af5-b777bf2faf5a", "name": "be5dac99-946a-4df5-8952-d1147d3fdd3b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7935386970404408, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.018922139033990728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "67770ecd-bc51-43f6-a467-df322344d97f", "name": "9b7192a2-8782-4dd6-925b-2fd55240b789", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "454c48ee-7a4d-4380-8af5-b777bf2faf5a"}}}]}, {"uuid": "2539222d-42f5-4f63-97e7-8c79633002cd", "name": "load_p1rlv672_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb25bf05-ce7f-405a-8c17-fd166748f7d3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "67770ecd-bc51-43f6-a467-df322344d97f"}}}}, {"uuid": "8a2565fc-2d10-411c-8b58-83ef9b8ba177", "name": "623d7d87-a72d-40d7-b15b-85211aeb8f62_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6873327290171372, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.38872845841522474, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "943ccbbf-545d-4d49-9fd9-da21451999ea", "name": "a0ff9f0f-f8db-4490-bb2a-c6659b925e09", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a2565fc-2d10-411c-8b58-83ef9b8ba177"}}}]}, {"uuid": "c22f9cd1-7aeb-4504-8fde-e07798bc325c", "name": "load_p1rlv673_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31d3267c-7020-4660-9a0b-49cd9d94a5d0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "943ccbbf-545d-4d49-9fd9-da21451999ea"}}}}, {"uuid": "52af43a7-2e10-476d-8f79-b64cc7623bfb", "name": "afc205a7-9f2d-4fd7-b294-a779ae841c7c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6873327290171372, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.38872845841522474, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "45401b66-ff96-4eea-9815-3750c71f19fe", "name": "2210476a-d427-48ac-aade-1e24916762a3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "52af43a7-2e10-476d-8f79-b64cc7623bfb"}}}]}, {"uuid": "56dd86e6-118f-4e7b-be9e-80e878193209", "name": "load_p1rlv673_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31d3267c-7020-4660-9a0b-49cd9d94a5d0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "45401b66-ff96-4eea-9815-3750c71f19fe"}}}}, {"uuid": "f23b238e-c41b-443f-976a-5439245d3616", "name": "282b9f7a-558f-4bae-be6b-4b852c874a38_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.629144238694082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9654448182756213, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1669e9ce-f614-4955-a87e-dd5775809296", "name": "465f7b3a-9ee2-4371-a88c-221f1773518a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f23b238e-c41b-443f-976a-5439245d3616"}}}]}, {"uuid": "bbeff04d-d4e6-49a0-8728-228f48fafd80", "name": "load_p1rlv674_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "449992d6-a91b-40ea-9792-5166a5f2c849"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1669e9ce-f614-4955-a87e-dd5775809296"}}}}, {"uuid": "697cc389-c07a-4dc3-86ea-c2559e23b687", "name": "413ebfd2-b99c-47df-90c6-dc5d1d8ea19e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.629144238694082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9654448182756213, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d1530a61-86d4-4018-bd0f-dcb9c860acb7", "name": "f8554fd1-2ba0-4cc7-b987-61922233324b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "697cc389-c07a-4dc3-86ea-c2559e23b687"}}}]}, {"uuid": "2a50a4d9-31db-4326-8b24-51ddf0b96e18", "name": "load_p1rlv674_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "449992d6-a91b-40ea-9792-5166a5f2c849"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d1530a61-86d4-4018-bd0f-dcb9c860acb7"}}}}, {"uuid": "e4d98caf-81e1-4441-b631-5c089e5d1282", "name": "a82f2924-5745-42c2-b066-45d94daed215_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2527429497469504, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5005012096685874, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1df1739a-2fb0-45e1-9b23-8363bbc5125c", "name": "df7aed15-398f-410c-829d-3b9905adf57a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e4d98caf-81e1-4441-b631-5c089e5d1282"}}}]}, {"uuid": "ede5311a-13dd-4156-8805-07596031707f", "name": "load_p1rlv716_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "93069f0f-fce7-47cd-b7b3-77e861f59573"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1df1739a-2fb0-45e1-9b23-8363bbc5125c"}}}}, {"uuid": "58392726-d0ac-4fe6-9dba-23581fc55985", "name": "f9fbe0ae-67ea-4039-9754-89cd2da347b0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2527429497469504, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5005012096685874, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2b89be86-388c-400b-b82c-a5e26babb039", "name": "acacb8f3-dd51-4dc1-9b99-7c14d0cd1ba5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58392726-d0ac-4fe6-9dba-23581fc55985"}}}]}, {"uuid": "1f87880a-e02f-4c82-a483-7f3d08ad74f0", "name": "load_p1rlv716_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "93069f0f-fce7-47cd-b7b3-77e861f59573"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2b89be86-388c-400b-b82c-a5e26babb039"}}}}, {"uuid": "bf496c73-e70e-423a-96b1-fec14de1cae3", "name": "f310019d-dc68-401e-a608-8f9873831b88_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.916354724025409, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9016755043678467, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ee026057-b475-41b4-9779-c9e655f595e4", "name": "55e3eda6-0059-4f6f-99e1-fd657134df3d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bf496c73-e70e-423a-96b1-fec14de1cae3"}}}]}, {"uuid": "bfa2a69f-a518-48d9-b301-9ecedffbc7df", "name": "load_p1rlv717_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd8fd159-f747-4ee4-a426-787f4eef4b42"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ee026057-b475-41b4-9779-c9e655f595e4"}}}}, {"uuid": "28596690-1a72-4eb3-88be-d63b33a6aa7b", "name": "e4e5404d-c770-4339-b715-c92a48adccff_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.916354724025409, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9016755043678467, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "38f4e1b1-3d21-4665-9b25-7d4717c4cf7d", "name": "588b544f-3513-4e91-b239-0cb86d9d9ab0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "28596690-1a72-4eb3-88be-d63b33a6aa7b"}}}]}, {"uuid": "afeb6c0e-ac4d-455f-aaf8-562288cbf02c", "name": "load_p1rlv717_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd8fd159-f747-4ee4-a426-787f4eef4b42"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "38f4e1b1-3d21-4665-9b25-7d4717c4cf7d"}}}}, {"uuid": "68031fd5-2533-4e56-9d65-f86eb933be4f", "name": "6db53d39-c949-4671-af40-bb2a932b8663_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.786120494572624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2344198860247402, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f056302a-9feb-4ed2-99b8-d266c61b39a6", "name": "af07bc93-3dcf-4220-8b1c-ecada1320a11", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "68031fd5-2533-4e56-9d65-f86eb933be4f"}}}]}, {"uuid": "977afcb1-5009-4ac4-b614-e3ca9da3a132", "name": "load_p1rlv718_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4a1453b-98a3-4c2d-8ac2-c8b2ab1bfa4f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f056302a-9feb-4ed2-99b8-d266c61b39a6"}}}}, {"uuid": "3585aea3-3794-4904-9bea-6f6577ba20d1", "name": "4ebb5e28-2f63-4b4f-b4b3-1e3f25027fba_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.786120494572624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2344198860247402, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f395d072-a839-4ac6-b22a-ba64f15a695f", "name": "dc5bb47e-ac2d-4fd7-9799-2d2244310396", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3585aea3-3794-4904-9bea-6f6577ba20d1"}}}]}, {"uuid": "acd07cca-61e9-4d04-a311-705836ab8e65", "name": "load_p1rlv718_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4a1453b-98a3-4c2d-8ac2-c8b2ab1bfa4f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f395d072-a839-4ac6-b22a-ba64f15a695f"}}}}, {"uuid": "b18f4b09-ed17-44bc-91ed-0c1ab5fd29f0", "name": "352ee402-7303-457c-8250-6c8740280031_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.872791085416893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.761492956317497, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6c62ae6d-d04e-4992-ae3f-25bd74f7a2f5", "name": "5b7571da-3ce0-486f-b952-4b3fea385372", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b18f4b09-ed17-44bc-91ed-0c1ab5fd29f0"}}}]}, {"uuid": "79c3a6fa-cd50-451c-96b7-2b35828c1130", "name": "load_p1rlv719_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3153167-8b4c-40e4-abb7-3bdef86950c3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6c62ae6d-d04e-4992-ae3f-25bd74f7a2f5"}}}}, {"uuid": "446dea59-a20d-4230-9868-466622a8596f", "name": "49bc3b2c-a430-418b-ae9b-1dbfe1acf7da_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.872791085416893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.761492956317497, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ed8a7b8a-0b5f-4835-96b4-03b2e8233240", "name": "022113f8-efad-4ccb-b324-6be956eedc22", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "446dea59-a20d-4230-9868-466622a8596f"}}}]}, {"uuid": "5d798181-b869-42ea-ad5c-4ffb250a43c6", "name": "load_p1rlv719_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3153167-8b4c-40e4-abb7-3bdef86950c3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ed8a7b8a-0b5f-4835-96b4-03b2e8233240"}}}}, {"uuid": "78dca5a5-2c84-4ac1-b8e3-d85046b179ac", "name": "4885aac2-d383-42d3-b012-fa12ac7c001b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.000000644073754, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1655557120603839, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b7861d22-0711-4175-8380-6949e323537c", "name": "c240c5ca-e0d0-49f6-89b3-f39f936d3cf4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "78dca5a5-2c84-4ac1-b8e3-d85046b179ac"}}}]}, {"uuid": "ae80bdbe-4444-4eac-97fb-51bcb6cc2d84", "name": "load_p1rlv720_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdbc11b7-5abf-4ff8-8d26-53faf4b1f3f5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b7861d22-0711-4175-8380-6949e323537c"}}}}, {"uuid": "1d863231-f17e-4b90-b3c8-a71a7ff0d81e", "name": "5428a001-da2b-48f0-8ac3-13506a749c4a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.000000644073754, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1655557120603839, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f0bdde55-7be0-4905-8777-cd2aff83f410", "name": "4154317d-cfc9-4a54-9941-94974a1c7930", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1d863231-f17e-4b90-b3c8-a71a7ff0d81e"}}}]}, {"uuid": "0d1c5f25-f550-471e-a519-97e3204a3ce9", "name": "load_p1rlv720_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdbc11b7-5abf-4ff8-8d26-53faf4b1f3f5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f0bdde55-7be0-4905-8777-cd2aff83f410"}}}}, {"uuid": "eb054f98-f757-4381-a754-386a4f692c7e", "name": "cd70e24d-36fb-4c38-9091-a607a7510221_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5041010955030301, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21577690333785765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1769bd12-ea2f-4e78-b9b4-d466df50ed95", "name": "e3a31a47-8ce6-4377-b101-b708d47ee0c4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eb054f98-f757-4381-a754-386a4f692c7e"}}}]}, {"uuid": "90a60c4d-b19b-45e9-88a5-f37644403db8", "name": "load_p1rlv721_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf12b67c-4df5-4dcb-a2e2-6ae2d0f82e65"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1769bd12-ea2f-4e78-b9b4-d466df50ed95"}}}}, {"uuid": "e6ccadcb-551c-4fce-9af8-b2c1ce35e751", "name": "adb54d5f-cca1-41b2-b7f0-30b4ca644bd3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5041010955030301, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21577690333785765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6d569f9f-5b10-4009-a8e9-d27ed169cb1c", "name": "f2aed3a1-839d-4ccd-b083-5939d16814d8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e6ccadcb-551c-4fce-9af8-b2c1ce35e751"}}}]}, {"uuid": "36af70ed-991f-4f4d-a0c6-02bfeb5237a9", "name": "load_p1rlv721_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf12b67c-4df5-4dcb-a2e2-6ae2d0f82e65"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6d569f9f-5b10-4009-a8e9-d27ed169cb1c"}}}}, {"uuid": "5f3616e6-0f56-49dc-962f-5a9371bb503e", "name": "be256f82-a4ca-4c22-aa1c-f53f933a408d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6733980323267108, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22626974414284334, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "900a87a8-5526-4eb4-b5a0-979080a61198", "name": "f62b6131-8890-4ca4-ac96-d20f59ace51b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5f3616e6-0f56-49dc-962f-5a9371bb503e"}}}]}, {"uuid": "ce2e7d49-8d13-4420-86ed-e25fa9f409cb", "name": "load_p1rlv722_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b7c6c65-e18c-4e79-b419-8894deb0d345"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "900a87a8-5526-4eb4-b5a0-979080a61198"}}}}, {"uuid": "91a1f911-9c6e-4f9d-b57a-24870fb2799a", "name": "3ced0a9a-c4e6-4a5a-ac86-9fed36368435_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6733980323267108, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22626974414284334, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8c040eae-447e-41cd-98e3-95b28f9c3636", "name": "9c50eea9-4cd9-45ca-9f4b-53d8c330a52f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "91a1f911-9c6e-4f9d-b57a-24870fb2799a"}}}]}, {"uuid": "af969afc-6753-4848-a059-1b3dd13285ac", "name": "load_p1rlv722_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b7c6c65-e18c-4e79-b419-8894deb0d345"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8c040eae-447e-41cd-98e3-95b28f9c3636"}}}}, {"uuid": "d0e3b089-c79e-4876-95b1-fb7d504380c2", "name": "4948e182-fabc-4164-82d3-ddf56e545b76_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2596055778412756, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4460523908595607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "120e19ed-92c5-4d00-b8b3-c9761ba75852", "name": "a7cc84eb-7b9c-4b97-a044-1f3f2bfadd43", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d0e3b089-c79e-4876-95b1-fb7d504380c2"}}}]}, {"uuid": "cc7beee9-ae31-4720-b679-66236113c044", "name": "load_p1rlv723_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7551be44-a4ca-4edb-b823-6495d163201e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "120e19ed-92c5-4d00-b8b3-c9761ba75852"}}}}, {"uuid": "f56ecadc-4862-4e7b-8afa-2d10acd0e581", "name": "0fde8a58-763b-43d1-93d1-4de9b34f2660_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2596055778412756, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4460523908595607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e82878f4-7239-4c3a-8d86-512ea4be2428", "name": "0b72b0d5-3710-48c1-8165-3fc647a05336", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f56ecadc-4862-4e7b-8afa-2d10acd0e581"}}}]}, {"uuid": "c03cf62f-3808-464a-b0b0-216bc94398b6", "name": "load_p1rlv723_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7551be44-a4ca-4edb-b823-6495d163201e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e82878f4-7239-4c3a-8d86-512ea4be2428"}}}}, {"uuid": "206ccb98-6132-4ee4-9c61-598990f1ef36", "name": "414d01c4-24ab-4828-bed6-9792187e017e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.794005533851084, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6855099409421886, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b839b6ba-2d40-44a3-8a83-1b9c240ff553", "name": "fe0822bd-009c-49aa-8c17-d6519e77523a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "206ccb98-6132-4ee4-9c61-598990f1ef36"}}}]}, {"uuid": "cda0e6a3-6816-4724-9d32-66cf642a638b", "name": "load_p1rlv724_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3658479-7369-4bd9-be54-e7768c93a808"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b839b6ba-2d40-44a3-8a83-1b9c240ff553"}}}}, {"uuid": "ab4a0044-8726-4027-8728-cab4f9c28832", "name": "d9befc77-f563-4e77-8348-4a35a3f6204c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.794005533851084, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6855099409421886, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5013d830-da3a-4cc4-bae0-872873f72f9d", "name": "3179e716-63ce-4f4e-84f7-a115095ff69b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ab4a0044-8726-4027-8728-cab4f9c28832"}}}]}, {"uuid": "32b32edf-0faa-4b81-8ce6-dc1f54bb4230", "name": "load_p1rlv724_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3658479-7369-4bd9-be54-e7768c93a808"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5013d830-da3a-4cc4-bae0-872873f72f9d"}}}}, {"uuid": "b17267ee-47c5-411a-a31b-ebe7f1237538", "name": "8ab8e5d0-1269-44e5-8fbe-90c56e6bea92_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7997673490012955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.772957044307952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "63ea1069-71be-457d-9839-65489224aa34", "name": "55100585-da78-4e58-bb3e-7b5689090e75", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b17267ee-47c5-411a-a31b-ebe7f1237538"}}}]}, {"uuid": "18c72770-ada5-451b-a875-7af3a4e7e5e4", "name": "load_p1rlv725_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2bcbabc-a7fc-4230-8ec1-b6050af9cf58"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "63ea1069-71be-457d-9839-65489224aa34"}}}}, {"uuid": "202490d4-2e13-4030-9563-cd2d19bd3793", "name": "5d799024-2182-434b-a3aa-eb41f7d2d023_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.7997673490012955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.772957044307952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2eba0569-eddf-44d2-b873-54968c0ff842", "name": "fc05ed22-e71c-46e6-94df-0433df5a2457", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "202490d4-2e13-4030-9563-cd2d19bd3793"}}}]}, {"uuid": "f7902d74-d4ed-43ba-af65-9db169a096e8", "name": "load_p1rlv725_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2bcbabc-a7fc-4230-8ec1-b6050af9cf58"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2eba0569-eddf-44d2-b873-54968c0ff842"}}}}, {"uuid": "35be8c28-4603-4c6d-b4bd-a972a67044dc", "name": "4020d951-95a0-453f-b69f-2cd0350929b1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.762685564172624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.7175951697927787, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4fefaa1d-8570-4fdd-908d-f3877c473c07", "name": "394b95f6-b12a-4cc1-98de-303c5877fe0a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "35be8c28-4603-4c6d-b4bd-a972a67044dc"}}}]}, {"uuid": "0b358c72-6f60-48ae-8c2c-3c786b5a52fc", "name": "load_p1rlv726_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fdcbc55-681f-4fe5-8142-4945b25f6fef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4fefaa1d-8570-4fdd-908d-f3877c473c07"}}}}, {"uuid": "654ab3ed-1580-4c7a-a3db-4cd47906bb85", "name": "aacb3ee5-917c-4517-b756-44a73b1213d8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.762685564172624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.7175951697927787, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2e4cb72a-c229-4b25-b5c8-012e536eb05a", "name": "d39ceafe-765a-4fa3-bbb0-01872c9a5dc1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "654ab3ed-1580-4c7a-a3db-4cd47906bb85"}}}]}, {"uuid": "bd703703-bee0-41ea-9c5a-2bb2e1a77c77", "name": "load_p1rlv726_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fdcbc55-681f-4fe5-8142-4945b25f6fef"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2e4cb72a-c229-4b25-b5c8-012e536eb05a"}}}}, {"uuid": "c9b17eaa-a404-4df1-aa43-fad0d049acac", "name": "914c059f-404a-49d2-be3f-3a4bbfa166d8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.981510789736824, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31377757670385525, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2e07e5a2-10ac-4133-a440-a0264b5555a1", "name": "b7887293-b0cd-4eb6-9448-45496ea31cbc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9b17eaa-a404-4df1-aa43-fad0d049acac"}}}]}, {"uuid": "7a93df03-8bc9-4742-b9f2-132964907df8", "name": "load_p1rlv749_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80983704-a98f-46dc-a09f-700bd7df1a29"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2e07e5a2-10ac-4133-a440-a0264b5555a1"}}}}, {"uuid": "1ccee909-af72-488c-ac95-cf3da56f22d5", "name": "fa888314-932e-4416-ab8a-3efe94677372_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.981510789736824, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31377757670385525, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4465aaeb-7114-4a39-88d9-ae13308d7239", "name": "d2c1e38f-6d88-4622-a3c7-9e43fa043ade", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1ccee909-af72-488c-ac95-cf3da56f22d5"}}}]}, {"uuid": "1748effe-25e9-4eb7-bf52-0121f8ec8725", "name": "load_p1rlv749_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80983704-a98f-46dc-a09f-700bd7df1a29"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4465aaeb-7114-4a39-88d9-ae13308d7239"}}}}, {"uuid": "97595f54-fa68-4bc7-a5d8-08e42f71deb9", "name": "5a922f5f-0a3a-4a86-b0b2-2bd83a97c70e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3612560165719545, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7198526424662817, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2284f4af-57f8-481e-845b-620d59dd587c", "name": "25785f91-6b3b-4678-ab4f-a5c1c5582b2e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "97595f54-fa68-4bc7-a5d8-08e42f71deb9"}}}]}, {"uuid": "4068cc20-6387-452c-b2d9-f20698ada793", "name": "load_p1rlv756_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3c3b0fb-5a5d-439e-a350-b97ba0df41a0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2284f4af-57f8-481e-845b-620d59dd587c"}}}}, {"uuid": "6dfd623a-6445-4a09-814a-c64d2133b497", "name": "78e36fd2-0a28-4227-bc4a-c4a8a7015c3b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3612560165719545, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7198526424662817, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2f73c189-c676-4215-b467-dc29671c2291", "name": "757afc2b-5fc3-49df-86c7-eb3e0da98a49", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6dfd623a-6445-4a09-814a-c64d2133b497"}}}]}, {"uuid": "6ad9daeb-12ab-4094-8f0a-f1d464b428a0", "name": "load_p1rlv756_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3c3b0fb-5a5d-439e-a350-b97ba0df41a0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2f73c189-c676-4215-b467-dc29671c2291"}}}}, {"uuid": "095ab4d6-8a69-462d-a850-f0b13520dbc4", "name": "14aa8b69-3b5d-4b12-9027-e1f27c344633_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.910200682298975, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5555412020426419, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a53fa2df-1c44-4551-970d-eaf3bf4ff3aa", "name": "671c0fa0-40f7-43af-8879-e9ed849c7b38", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "095ab4d6-8a69-462d-a850-f0b13520dbc4"}}}]}, {"uuid": "49bfdc0b-b1f1-4793-a1ee-c23ebccfb7ca", "name": "load_p1rlv764_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e368704b-6c4b-4afb-a577-4b0d7a96dd65"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a53fa2df-1c44-4551-970d-eaf3bf4ff3aa"}}}}, {"uuid": "98e825f3-67b7-4c37-94e4-ba4cd44d1c77", "name": "75b95e6b-993e-49d1-beaf-05ad1485d9dc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.910200682298975, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5555412020426419, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ac754445-1442-4550-905e-8e707d74471b", "name": "cba8842f-933e-489e-addf-3b06dcb6b8f1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "98e825f3-67b7-4c37-94e4-ba4cd44d1c77"}}}]}, {"uuid": "76bba039-59f2-4f78-8883-71aa2de6a56f", "name": "load_p1rlv764_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e368704b-6c4b-4afb-a577-4b0d7a96dd65"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ac754445-1442-4550-905e-8e707d74471b"}}}}, {"uuid": "da122198-fdf4-4f17-91f4-a07f00b0635a", "name": "d2b79295-98d1-4ac5-9fd4-50f63968a697_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4856814769108864, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8267323554826451, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "981253cf-9ec0-46de-96c7-894d0ea481f3", "name": "14cc4b68-7bdb-4ee6-85d8-136e91f1acbc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "da122198-fdf4-4f17-91f4-a07f00b0635a"}}}]}, {"uuid": "bd077c4a-347f-469a-9666-a1ffd44e74e9", "name": "load_p1rlv766_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07381934-8e9b-4447-a330-e8af484331f1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "981253cf-9ec0-46de-96c7-894d0ea481f3"}}}}, {"uuid": "44b0c0d9-18c0-456c-badf-3f0150e3ff71", "name": "376debc5-4871-42ec-a45b-c7ca0f7641fb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4856814769108864, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8267323554826451, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "24537064-7722-4085-ae94-ad0a58eafd75", "name": "a38cdba4-704d-4fa8-ba52-cd2636dd6f24", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "44b0c0d9-18c0-456c-badf-3f0150e3ff71"}}}]}, {"uuid": "cb470b47-d7b1-400f-8605-511c302fd177", "name": "load_p1rlv766_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07381934-8e9b-4447-a330-e8af484331f1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "24537064-7722-4085-ae94-ad0a58eafd75"}}}}, {"uuid": "2d0835b7-8d42-4dbe-bab2-b7cf2bd0a3ce", "name": "c9a27d67-ee66-48b5-9c74-241a63a61769_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7083181921938193, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5666922324635131, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b009a683-06f5-412d-b28a-2d70d330b918", "name": "12fdd19f-c9c9-4712-87a7-0eb4cfeeea43", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2d0835b7-8d42-4dbe-bab2-b7cf2bd0a3ce"}}}]}, {"uuid": "af3c78f3-2c17-4189-920c-66419131c6f5", "name": "load_p1rlv775_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d00977fb-8d2a-44ca-aa9e-034894d6e280"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b009a683-06f5-412d-b28a-2d70d330b918"}}}}, {"uuid": "bfa66587-5224-4964-bf22-adc45a8102b5", "name": "efb56f1f-ea09-462e-bf7a-c0d3aef7d273_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7083181921938193, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5666922324635131, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "af7f6606-be0b-4ffb-9ad5-14dc2b7b129c", "name": "f4304dad-8b4c-4aec-b5ba-69374fbc18a6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bfa66587-5224-4964-bf22-adc45a8102b5"}}}]}, {"uuid": "e98e2389-7cf7-4dd2-92bd-be1be91c4a06", "name": "load_p1rlv775_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d00977fb-8d2a-44ca-aa9e-034894d6e280"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "af7f6606-be0b-4ffb-9ad5-14dc2b7b129c"}}}}, {"uuid": "c647da92-87b1-48a3-92c2-188de6a9533d", "name": "7da23661-24f7-4c1d-84c2-5e0d59552fad_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.779437116944347, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0510023138100544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bba4366b-4b54-4a75-a4b3-4ba63f4de749", "name": "91699525-1af6-4e00-b7c7-5cd4d14db0dd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c647da92-87b1-48a3-92c2-188de6a9533d"}}}]}, {"uuid": "bf3f6187-ae8e-4b4a-bac1-260d3b7c7bba", "name": "load_p1rlv776_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c5b1f75-47c0-45c3-9ef3-f97a445b242e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bba4366b-4b54-4a75-a4b3-4ba63f4de749"}}}}, {"uuid": "ed7c1fbd-90bd-42f8-bdda-65b54bacce7c", "name": "0b724cdf-7e23-40d8-85ef-44b2fef77f36_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.779437116944347, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0510023138100544, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "68bafba1-5b2b-40db-b17e-442cca8e5d82", "name": "c9bae9e4-9c6d-4106-81be-52b260b3b36e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ed7c1fbd-90bd-42f8-bdda-65b54bacce7c"}}}]}, {"uuid": "8f8d4df1-5a48-4c4c-b74b-f1c95de4cc03", "name": "load_p1rlv776_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c5b1f75-47c0-45c3-9ef3-f97a445b242e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "68bafba1-5b2b-40db-b17e-442cca8e5d82"}}}}, {"uuid": "0df6d500-fb5a-4499-a196-31a12b23a034", "name": "be8c7f3b-9a68-4c98-9632-9cdbf579b8cb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3483029031483318, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6505451661884267, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b0a276b7-d3fc-4c8f-9da5-216c398babf3", "name": "334fc552-b885-4faa-bb7e-c1332260f2e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0df6d500-fb5a-4499-a196-31a12b23a034"}}}]}, {"uuid": "da976a87-52f4-48fc-b48d-c87ee7f367c3", "name": "load_p1rlv777_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fb1fca8-7985-4356-a8de-7433fef7a454"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b0a276b7-d3fc-4c8f-9da5-216c398babf3"}}}}, {"uuid": "f184f240-c154-4d08-99f3-6d35887d55fc", "name": "a20f9e8b-6285-4a23-bf3c-811d440ca941_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3483029031483318, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6505451661884267, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8fd141ec-66ef-48ae-b92c-051f229c57bd", "name": "88f79e12-1637-4b3c-84a6-497f9c34b51c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f184f240-c154-4d08-99f3-6d35887d55fc"}}}]}, {"uuid": "88825692-476f-466b-852c-5593f1a76bd5", "name": "load_p1rlv777_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fb1fca8-7985-4356-a8de-7433fef7a454"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8fd141ec-66ef-48ae-b92c-051f229c57bd"}}}}, {"uuid": "e3d3a257-3499-4ef3-a6fb-094615787127", "name": "58a200ee-cf6d-4ebd-8eee-13d37cba4efe_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.993849790823018, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8230403105677124, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dbc24d2f-ac5a-4014-9727-f3022d456fe8", "name": "4d093c92-29a0-4276-b2aa-0fc8f4ea3b6d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e3d3a257-3499-4ef3-a6fb-094615787127"}}}]}, {"uuid": "cf15fdf4-d3ca-4b4f-8331-3cfee831711f", "name": "load_p1rlv778_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80d58665-ee8a-4f4e-a906-dc15aa3d8c6f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dbc24d2f-ac5a-4014-9727-f3022d456fe8"}}}}, {"uuid": "ad44b362-b8d0-43f7-88fa-5e95294fc979", "name": "83ad46c7-97e5-41bc-a258-e129c9919c7d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.993849790823018, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8230403105677124, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "af72f8ad-1709-4aa0-bd4f-a57fe996c2b8", "name": "a4c6f312-dfb4-4684-90b7-89d96afcd6e1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ad44b362-b8d0-43f7-88fa-5e95294fc979"}}}]}, {"uuid": "c1643d04-ee94-4c42-a3fa-5a9649da51c2", "name": "load_p1rlv778_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80d58665-ee8a-4f4e-a906-dc15aa3d8c6f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "af72f8ad-1709-4aa0-bd4f-a57fe996c2b8"}}}}, {"uuid": "8fda77fb-2ca6-4aae-833e-2dc48e283d3a", "name": "8f978ad7-6b29-4136-bb49-a260293e3694_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9928270585646484, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0482885249865175, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "be510307-835d-455c-a22a-907e1c4aaf34", "name": "a4e10a40-6b35-4702-b2ef-dff0376c1927", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8fda77fb-2ca6-4aae-833e-2dc48e283d3a"}}}]}, {"uuid": "bd460ab7-6f33-4ad8-bab9-c7975ca760fe", "name": "load_p1rlv779_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fbc761bf-480c-465c-9479-279832c50bc2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "be510307-835d-455c-a22a-907e1c4aaf34"}}}}, {"uuid": "757268af-82cf-4c04-8286-0ce4dfa4b093", "name": "3ee4a450-9481-4eb5-b237-5c5a878e489a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9928270585646484, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0482885249865175, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d89ab889-d4db-4be6-9a90-26f73ba46828", "name": "b35d9fbe-013c-4a1c-83b9-4ab26d855305", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "757268af-82cf-4c04-8286-0ce4dfa4b093"}}}]}, {"uuid": "95c38f40-9c71-4894-8b76-b5299a47976e", "name": "load_p1rlv779_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fbc761bf-480c-465c-9479-279832c50bc2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d89ab889-d4db-4be6-9a90-26f73ba46828"}}}}, {"uuid": "de388c37-805e-46eb-be1f-9964021fb441", "name": "6eb3ddcf-b9b7-46c4-b045-4a3c23614f63_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1813646779377422, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20173832232537287, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7747797d-7399-4cfd-94fb-22f3f4208b34", "name": "cd15d90f-9046-4e94-80cc-c53c23cbcc2d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "de388c37-805e-46eb-be1f-9964021fb441"}}}]}, {"uuid": "e1ef1997-11c2-4bde-9614-10e1366bbfa7", "name": "load_p1rlv780_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20dcf67f-f04f-498a-830d-557ba7b4d867"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7747797d-7399-4cfd-94fb-22f3f4208b34"}}}}, {"uuid": "1d52a042-3b51-466c-b0b9-9793f90674f1", "name": "c6cc7966-7cb6-477f-b0aa-90853888976c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1813646779377422, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20173832232537287, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fb5b0f15-a6a3-4798-9359-04c664a0b337", "name": "de37e0df-b3dc-4372-8ca5-780e264ad2dc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1d52a042-3b51-466c-b0b9-9793f90674f1"}}}]}, {"uuid": "eaefd462-04ca-4b42-9951-de5390cfad14", "name": "load_p1rlv780_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20dcf67f-f04f-498a-830d-557ba7b4d867"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fb5b0f15-a6a3-4798-9359-04c664a0b337"}}}}, {"uuid": "df814907-32b4-490b-85d9-6989f1b2c207", "name": "07d5c973-7b09-4ca3-a5f4-762245e9177f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.774034588817963, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.005441618856208, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6ddcad46-046e-4970-bf6c-38a406e4c1a4", "name": "92d1d692-2e0d-4fc2-88ab-4c4eb635fa55", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "df814907-32b4-490b-85d9-6989f1b2c207"}}}]}, {"uuid": "1de06a56-a8a4-480a-a591-c39f83bf866b", "name": "load_p1rlv781_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98c5ba15-a339-478a-a79f-9298fab16a54"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6ddcad46-046e-4970-bf6c-38a406e4c1a4"}}}}, {"uuid": "ae008260-0220-4b43-bb09-b7a4db443cd6", "name": "9e31d366-716f-40d7-b4b5-357d54d0210a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.774034588817963, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.005441618856208, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f9734d7e-7513-4ce5-a13d-dbc4a0bbddb0", "name": "f503e21e-f463-4a19-8165-e9b74dfdb2bf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ae008260-0220-4b43-bb09-b7a4db443cd6"}}}]}, {"uuid": "2788224b-ffa0-4a6d-a6cb-1f419fca2c75", "name": "load_p1rlv781_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98c5ba15-a339-478a-a79f-9298fab16a54"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f9734d7e-7513-4ce5-a13d-dbc4a0bbddb0"}}}}, {"uuid": "d0474588-6987-431b-b039-72a024c5dae3", "name": "ab458b61-6fdc-437e-81f1-1481b840cc6c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7457942211533133, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8784341351558463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8e6e17c4-cccb-448b-bc16-ddf2158f70eb", "name": "8d70e38a-f57a-492f-9eba-5eb3f9019373", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d0474588-6987-431b-b039-72a024c5dae3"}}}]}, {"uuid": "bdf2cf7b-27a6-44ac-bff7-46e9c4ca9478", "name": "load_p1rlv782_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78a4f54a-017a-41b0-85c8-b3e408c21c08"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8e6e17c4-cccb-448b-bc16-ddf2158f70eb"}}}}, {"uuid": "6c14eafc-a7e2-46ce-9633-4b0777173e5b", "name": "1a084ecc-2ae8-4b1f-89b3-57a1d6d523cb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7457942211533133, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8784341351558463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "99378bc7-2911-4588-b03d-343b24aff733", "name": "b06b5fa9-00fe-479c-9711-aa527b5edbb0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c14eafc-a7e2-46ce-9633-4b0777173e5b"}}}]}, {"uuid": "e354d758-9648-4666-9d70-b77f5f1f4737", "name": "load_p1rlv782_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78a4f54a-017a-41b0-85c8-b3e408c21c08"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "99378bc7-2911-4588-b03d-343b24aff733"}}}}, {"uuid": "b24be7a9-3b59-4dc6-9298-d2905610d3aa", "name": "67db29c6-ad14-4b02-ad74-5ad57266c59e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0085854932437286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7150296414254909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8b88af4f-60ed-40e2-b8bf-1abff861db1e", "name": "12db7d6d-fa2f-4fca-bb8b-337ae132b8d9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b24be7a9-3b59-4dc6-9298-d2905610d3aa"}}}]}, {"uuid": "aade8390-df77-43bb-aaa2-244c12fee2fa", "name": "load_p1rlv783_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d1a96d5-f971-4116-9642-769ef5b97e7c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8b88af4f-60ed-40e2-b8bf-1abff861db1e"}}}}, {"uuid": "d5a5cd6a-c6a5-4fc5-8189-3a3b37c9b27a", "name": "ca63e231-3b8d-41bf-ac0b-0063b1db375a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0085854932437286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7150296414254909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ed040046-fa14-42be-9b37-7f7367b7dd4c", "name": "03707f96-fecf-4a1a-90ac-9a69dad2f714", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d5a5cd6a-c6a5-4fc5-8189-3a3b37c9b27a"}}}]}, {"uuid": "d52c6675-0c5d-4f90-bbac-83a9d5e1fb0a", "name": "load_p1rlv783_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d1a96d5-f971-4116-9642-769ef5b97e7c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ed040046-fa14-42be-9b37-7f7367b7dd4c"}}}}, {"uuid": "619dcfdf-f040-45a9-85f7-1e3ef0ec179a", "name": "7eb8803a-c167-4382-a54b-b2af56d8c932_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.965154260277072, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307595255595673, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50a79a8f-7190-4a2d-9d6d-5523568e51f8", "name": "c2d95147-22cb-4130-980a-eab5c2c596d6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "619dcfdf-f040-45a9-85f7-1e3ef0ec179a"}}}]}, {"uuid": "80dfbff6-7bba-43d8-9d0e-4164c32441c6", "name": "load_p1rlv784_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2823b5b9-bcc3-4b30-9874-89dc33ec80d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50a79a8f-7190-4a2d-9d6d-5523568e51f8"}}}}, {"uuid": "deb8610a-ede2-4a10-9146-967487bff884", "name": "294b3492-4155-4b3e-9a69-ac3490d2a85d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.965154260277072, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6307595255595673, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1aef9c37-bb70-4ff6-ba21-a0d54c639258", "name": "aef5eabe-1271-4dde-9863-73bfb164f73a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "deb8610a-ede2-4a10-9146-967487bff884"}}}]}, {"uuid": "913c5b60-19da-4ec3-b487-ec0578ce1904", "name": "load_p1rlv784_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2823b5b9-bcc3-4b30-9874-89dc33ec80d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1aef9c37-bb70-4ff6-ba21-a0d54c639258"}}}}, {"uuid": "c9e7b15c-61f7-4b86-90e4-bfc2aad74f55", "name": "7713e8c5-850d-43cb-a2c3-91f3834f43d7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.948680292874151, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.769988963438003, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "45345969-43ff-4427-b01b-d383cffda331", "name": "1790b739-e6c0-4648-b2ae-649d4abe5778", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9e7b15c-61f7-4b86-90e4-bfc2aad74f55"}}}]}, {"uuid": "3ac66ec1-6fb6-4c36-a2c3-e32d08f7d9ac", "name": "load_p1rlv785_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa98d6c6-7086-4033-a9af-c0a33e802942"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "45345969-43ff-4427-b01b-d383cffda331"}}}}, {"uuid": "fb9f3072-5ef5-48d6-9d07-2d2658810068", "name": "bd9c4191-59de-45a1-814b-d90568788fe8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.948680292874151, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.769988963438003, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "593c1512-b383-4ac8-98a4-827a2fcb93a6", "name": "177fe3d7-2b35-484b-875f-e7d560930137", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fb9f3072-5ef5-48d6-9d07-2d2658810068"}}}]}, {"uuid": "e1ddc0aa-3e8d-4766-a484-644f692e29e1", "name": "load_p1rlv785_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa98d6c6-7086-4033-a9af-c0a33e802942"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "593c1512-b383-4ac8-98a4-827a2fcb93a6"}}}}, {"uuid": "bc760cd2-a200-4bfd-9186-1f7acd7a1a81", "name": "456087ae-8687-410b-a07b-5303e9da9193_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0491915565570302, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1506537762556939, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5b15a43f-f62b-4614-9c68-35ba1f43fb5c", "name": "186ec91e-c15b-4f56-98ff-82750ff6d8db", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bc760cd2-a200-4bfd-9186-1f7acd7a1a81"}}}]}, {"uuid": "d859e8e9-e36f-418b-a618-7d5a905ca868", "name": "load_p1rlv786_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180adab2-e49b-42e9-9aeb-42be0a7686c5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5b15a43f-f62b-4614-9c68-35ba1f43fb5c"}}}}, {"uuid": "3a1c632a-ce42-42cb-ae94-48b8907ff209", "name": "bb5dcfcf-f220-438e-a891-8f1e45366dbb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0491915565570302, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1506537762556939, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aae090e5-66ce-4226-a0dc-088b17d1c483", "name": "c65f9925-017a-4930-8312-dade9bf74b58", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3a1c632a-ce42-42cb-ae94-48b8907ff209"}}}]}, {"uuid": "8dd7c44e-a653-498e-be77-b6b12110969f", "name": "load_p1rlv786_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180adab2-e49b-42e9-9aeb-42be0a7686c5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aae090e5-66ce-4226-a0dc-088b17d1c483"}}}}, {"uuid": "473251b2-1ab4-4ce0-bfea-f97b3f8f6ebb", "name": "79beb2c9-bac5-4287-a9ef-9ce61c94224a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.246762625041277, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42085270345980447, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0891e070-d97c-48e0-ba7d-2b680fa93ce3", "name": "adaf6100-1d2d-4134-a35b-50bc5f41a61d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "473251b2-1ab4-4ce0-bfea-f97b3f8f6ebb"}}}]}, {"uuid": "85d88516-8681-4092-8522-e96e03808247", "name": "load_p1rlv787_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0089ee3-0cb4-434c-adc4-c91a8441ef0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0891e070-d97c-48e0-ba7d-2b680fa93ce3"}}}}, {"uuid": "65eaa6dd-e9ea-4531-b49b-9e6c44dfb463", "name": "fc3a09c9-d1fc-47ad-ba9f-e05638d984b6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.246762625041277, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42085270345980447, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5183e717-19d2-4093-a229-bfdecdd6a6b7", "name": "57ceeb5c-7caa-4188-ac3e-484dd9a20a93", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "65eaa6dd-e9ea-4531-b49b-9e6c44dfb463"}}}]}, {"uuid": "fa119cc4-4020-42a3-bed6-cb4c53fe15f7", "name": "load_p1rlv787_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0089ee3-0cb4-434c-adc4-c91a8441ef0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5183e717-19d2-4093-a229-bfdecdd6a6b7"}}}}, {"uuid": "7eb3f9c1-caf9-45b3-854a-b2e7498e6012", "name": "caa89576-3694-45c2-b0d2-dfa67d478a27_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8660061383019082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.44544683702444765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "30ce92a9-817f-477c-a08d-b1c98ef75f61", "name": "1f49a407-37ad-484a-8b93-f026dedbc504", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7eb3f9c1-caf9-45b3-854a-b2e7498e6012"}}}]}, {"uuid": "a6ef7793-92d0-4190-9487-746bd46b1fe3", "name": "load_p1rlv788_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9f470d9-6ead-4413-ad8a-7ccc69ae9237"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "30ce92a9-817f-477c-a08d-b1c98ef75f61"}}}}, {"uuid": "1fe997d5-481e-4bb5-886a-36f042ab7a4a", "name": "76064b24-cdad-4a93-b0aa-69817f67638c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8660061383019082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.44544683702444765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4b9db413-91c2-4b76-9e16-748421872017", "name": "f135eded-859b-48d6-a770-7d6ce70bceb3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1fe997d5-481e-4bb5-886a-36f042ab7a4a"}}}]}, {"uuid": "a1293b75-945a-4a8b-9e75-47fe77b2ac08", "name": "load_p1rlv788_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9f470d9-6ead-4413-ad8a-7ccc69ae9237"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4b9db413-91c2-4b76-9e16-748421872017"}}}}, {"uuid": "2995fa38-c796-407f-b921-aa40a63a21a5", "name": "da1c4ecf-5cec-4267-81c4-b45fc78f34d1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1146755706450526, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5956233891083068, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3f242781-55ca-45dc-80f0-7e15ad23a6ca", "name": "63e7d2cd-0504-4847-8012-5e2723d55f6a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2995fa38-c796-407f-b921-aa40a63a21a5"}}}]}, {"uuid": "07f0059d-15e9-4a01-9e08-bee0656f3c1b", "name": "load_p1rlv789_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9ce2439-fcc7-4965-81ee-f875db83b003"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3f242781-55ca-45dc-80f0-7e15ad23a6ca"}}}}, {"uuid": "cd40daea-6940-49fa-b2d8-685091be24c7", "name": "7cc7695b-9b9e-42fc-b8fd-de7fda9a3f7f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1146755706450526, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5956233891083068, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "abd3d946-ff0d-4c90-b67c-3a474857170f", "name": "cfc12075-8e2f-4e2d-9c71-5c99072bdd41", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cd40daea-6940-49fa-b2d8-685091be24c7"}}}]}, {"uuid": "8e04a276-1831-4a10-89ac-8e0cc810ac43", "name": "load_p1rlv789_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9ce2439-fcc7-4965-81ee-f875db83b003"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "abd3d946-ff0d-4c90-b67c-3a474857170f"}}}}, {"uuid": "67358195-51ef-441c-a590-de52ce404ae5", "name": "313602cc-e67f-4578-abdd-9f8eb3be2c03_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.507865878359724, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5977385470921427, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a32bf0e6-797a-4730-a940-ac2793a72dda", "name": "390e6fa0-70fa-4622-953b-612514c57b46", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "67358195-51ef-441c-a590-de52ce404ae5"}}}]}, {"uuid": "32d4ada8-ea2a-4266-9e2e-0aee1c3746c3", "name": "load_p1rlv790_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf42fa7f-370e-400e-8f6d-76eb8c70ecb9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a32bf0e6-797a-4730-a940-ac2793a72dda"}}}}, {"uuid": "059c12b8-7a4d-474e-b868-f82f1115f672", "name": "d3aa0c32-6da1-4087-b743-172cc3bf2a07_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.507865878359724, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5977385470921427, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bc4817fe-0da3-43f5-ad60-a477d7c8576b", "name": "2a94ff1c-f549-461e-8968-54329535288e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "059c12b8-7a4d-474e-b868-f82f1115f672"}}}]}, {"uuid": "cd07f9ea-7435-4b93-8fcc-a44d99da4aae", "name": "load_p1rlv790_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf42fa7f-370e-400e-8f6d-76eb8c70ecb9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bc4817fe-0da3-43f5-ad60-a477d7c8576b"}}}}, {"uuid": "f2079efb-f07c-41bc-94c2-584ae629605d", "name": "86210398-a9a8-4879-9e3c-b7e182dc94e5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.8801930784369265, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0115137645096066, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "58867ff1-aac8-41f5-a8f6-037f853e3cd6", "name": "72ae5231-2aed-4bdb-b71a-f9c042ea9b3f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f2079efb-f07c-41bc-94c2-584ae629605d"}}}]}, {"uuid": "6d6e5bd0-4069-4b2b-8a3b-a4b8156b0b6b", "name": "load_p1rlv791_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fe9bb3f-e3c1-4b59-b39f-f62271a55bdd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "58867ff1-aac8-41f5-a8f6-037f853e3cd6"}}}}, {"uuid": "cc6c614d-1f66-4f40-a958-de8b63523d00", "name": "1d8a2af4-40d4-47c0-a99f-71754c62732e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.8801930784369265, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0115137645096066, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d576a3e9-8707-405e-ad02-8b47148a6b96", "name": "458448a9-d21f-4598-ba66-2148ed15878b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cc6c614d-1f66-4f40-a958-de8b63523d00"}}}]}, {"uuid": "1fb64f7e-30c1-4b55-b646-32d6d63c9137", "name": "load_p1rlv791_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fe9bb3f-e3c1-4b59-b39f-f62271a55bdd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d576a3e9-8707-405e-ad02-8b47148a6b96"}}}}, {"uuid": "c8ca456b-103e-40a8-826f-9658b81c0c8c", "name": "a58593df-f306-44d4-956d-19bd50b79f7a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7628538083737542, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7287957147649712, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d505cfe9-c55f-44e1-a8d2-8b1fffbb1241", "name": "106e892e-878c-4a5c-ad20-d2887fbfb751", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c8ca456b-103e-40a8-826f-9658b81c0c8c"}}}]}, {"uuid": "31f2fd4f-1cac-4765-a201-816b91860a72", "name": "load_p1rlv792_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f806232e-0a52-46d5-80f7-7ea3a914137a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d505cfe9-c55f-44e1-a8d2-8b1fffbb1241"}}}}, {"uuid": "92485c07-f490-4bbc-a625-20051376dba7", "name": "e18075de-75e7-40cb-a8c4-29a5ff6f87ed_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7628538083737542, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7287957147649712, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "967be153-6d35-4c97-a427-d053a9ef357e", "name": "a2138130-423b-4e33-8b77-76ebb1b6dafa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "92485c07-f490-4bbc-a625-20051376dba7"}}}]}, {"uuid": "b24d80d1-0fb7-41c9-98d8-b2e48b6d99c1", "name": "load_p1rlv792_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f806232e-0a52-46d5-80f7-7ea3a914137a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "967be153-6d35-4c97-a427-d053a9ef357e"}}}}, {"uuid": "4f125316-f1dc-4264-a48a-3eb422837b73", "name": "ca0b469e-5b49-4e05-a6e6-f1796455c4fe_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3510125413548424, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5621017434083633, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7f3c53b7-1c9e-4f38-aa93-41bfe2410c5f", "name": "096b7ce4-2993-4f74-a691-64c767bd5807", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4f125316-f1dc-4264-a48a-3eb422837b73"}}}]}, {"uuid": "6624cffa-97dd-4f2f-a93c-6283af6764c1", "name": "load_p1rlv793_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e8c4bc9-0688-43e6-93a8-9664c9b618b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7f3c53b7-1c9e-4f38-aa93-41bfe2410c5f"}}}}, {"uuid": "48ff241c-9d0d-4e99-9630-c7c010dcbfc4", "name": "458cf665-3d81-4248-8d50-75e991f6dd7a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3510125413548424, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5621017434083633, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "25886f1d-2b99-4844-9818-12e1072e4078", "name": "fdb32a95-93af-4633-951a-7ce676661d31", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "48ff241c-9d0d-4e99-9630-c7c010dcbfc4"}}}]}, {"uuid": "ba48e384-469b-4bfe-b930-408e95243541", "name": "load_p1rlv793_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e8c4bc9-0688-43e6-93a8-9664c9b618b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "25886f1d-2b99-4844-9818-12e1072e4078"}}}}, {"uuid": "a433be39-5d29-46d5-af99-b5433f4eb28e", "name": "4cbdee84-762e-4ffe-b5ca-739d59c579f6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8660061383019082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.44544683702444765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "563fee7b-f9a7-4c21-ad96-84ff8c32ca24", "name": "794f19a1-12cb-4fd3-8a38-28db448457eb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a433be39-5d29-46d5-af99-b5433f4eb28e"}}}]}, {"uuid": "d4736669-6c0f-458e-b2bf-564059c09a88", "name": "load_p1rlv794_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eecc456-41af-4242-ab30-d8ca45d55a2c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "563fee7b-f9a7-4c21-ad96-84ff8c32ca24"}}}}, {"uuid": "ed90e9c2-75fc-4ccb-a6ea-9678e556a42b", "name": "fa8d3016-4cf5-4d13-b2fa-6e4f6cd801c1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8660061383019082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.44544683702444765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "46083046-bc68-4957-9762-f7c32f3ed87a", "name": "73f557bd-a82b-4859-a8a7-96565bb7ca35", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ed90e9c2-75fc-4ccb-a6ea-9678e556a42b"}}}]}, {"uuid": "77460682-1d6c-4df8-8eae-c8393e31aca8", "name": "load_p1rlv794_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eecc456-41af-4242-ab30-d8ca45d55a2c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "46083046-bc68-4957-9762-f7c32f3ed87a"}}}}, {"uuid": "6c710181-e2b6-4826-b884-cb0d10b219a0", "name": "253e183e-ba89-4e13-b8ad-ff127796e36c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.083951745833768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9853982282300497, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0653bc01-11d5-4990-9a66-94333ae0f39e", "name": "94bdb433-37d8-4f57-8525-84aec78cf6a4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c710181-e2b6-4826-b884-cb0d10b219a0"}}}]}, {"uuid": "1842e1ea-1f3a-44f6-86da-050c29265f33", "name": "load_p1rlv795_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb137176-0642-4d87-ae40-1b7b0e1cb214"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0653bc01-11d5-4990-9a66-94333ae0f39e"}}}}, {"uuid": "c9e78314-1f2b-48b3-86db-2504aa47b9d1", "name": "517dfb60-554d-4efb-95e7-209b287750bd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.083951745833768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9853982282300497, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e17db933-2332-4184-acb3-983d9976b88d", "name": "00024c62-6f74-4838-ac6f-c4e4ab032493", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9e78314-1f2b-48b3-86db-2504aa47b9d1"}}}]}, {"uuid": "11d0c30a-c620-42e1-9c1b-108bbaf9c2c8", "name": "load_p1rlv795_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb137176-0642-4d87-ae40-1b7b0e1cb214"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e17db933-2332-4184-acb3-983d9976b88d"}}}}, {"uuid": "dd4817ff-9567-48fc-a612-d4f252b795a5", "name": "34accbdf-746d-4883-9760-04afcf68e08e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0085854932437286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7150296414254909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "755376c1-8d90-4413-bb42-962c9347ffbf", "name": "29e47ff3-8353-40ff-8f54-01b484e9267c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dd4817ff-9567-48fc-a612-d4f252b795a5"}}}]}, {"uuid": "32b85a02-d101-4205-852e-f12e6d5349e0", "name": "load_p1rlv796_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59662cef-c126-4188-ad86-844f6cabaf34"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "755376c1-8d90-4413-bb42-962c9347ffbf"}}}}, {"uuid": "d09ed02f-0edd-4bc2-83fd-f36c855f6ec6", "name": "764f4a73-d05f-4d60-9bd3-bf7d1e36c0e1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0085854932437286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7150296414254909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "79449805-4e72-494a-87d2-57dad2817656", "name": "7bba4b8f-3ec6-4e8c-bf7d-471827c3cd54", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d09ed02f-0edd-4bc2-83fd-f36c855f6ec6"}}}]}, {"uuid": "44f27ce1-c9f1-4f28-a727-53e65be90070", "name": "load_p1rlv796_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59662cef-c126-4188-ad86-844f6cabaf34"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "79449805-4e72-494a-87d2-57dad2817656"}}}}, {"uuid": "b5f8d76c-a753-4d81-b731-5d3dff6e99d9", "name": "5a907586-3b6b-44f9-b487-1a3d596627ed_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.127438645009231, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8176304041402817, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c6a0a7a4-5fe0-4b41-8a8f-0a33c6123d0b", "name": "0926481c-375c-45c6-8bc9-796e6fccc09b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5f8d76c-a753-4d81-b731-5d3dff6e99d9"}}}]}, {"uuid": "a12f00cb-3c93-410c-a003-2b94e48aeec0", "name": "load_p1rlv797_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b1c34f1-2613-46aa-9a9f-686ee518e559"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c6a0a7a4-5fe0-4b41-8a8f-0a33c6123d0b"}}}}, {"uuid": "1518672b-3dd9-496d-8565-f93c0eed2369", "name": "7a4a591f-f997-471d-ab7e-16e7d400ace9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.127438645009231, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8176304041402817, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a47ee959-4933-4ad4-ae2c-7fe6b20ce82a", "name": "ac50e232-492f-46d1-8e34-e3bfc191470b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1518672b-3dd9-496d-8565-f93c0eed2369"}}}]}, {"uuid": "cf856919-7fc5-4818-8d6f-28087f021ebe", "name": "load_p1rlv797_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b1c34f1-2613-46aa-9a9f-686ee518e559"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a47ee959-4933-4ad4-ae2c-7fe6b20ce82a"}}}}, {"uuid": "d4417dbc-b4db-49bd-8feb-627965850552", "name": "7bd8265e-cdf2-4bc7-ad3d-09ac6aeb4d16_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.839033632547656, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.36892018645953045, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b7b0c9cb-b446-4f62-9873-638405bd7a3d", "name": "437537d8-a0dd-416a-a449-1a6a634f5d26", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d4417dbc-b4db-49bd-8feb-627965850552"}}}]}, {"uuid": "1a71adb8-ddc6-4746-9b53-90cfd4bf60ac", "name": "load_p1rlv798_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c30005d7-7e42-4a08-8935-0c7227fba4a6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b7b0c9cb-b446-4f62-9873-638405bd7a3d"}}}}, {"uuid": "86ef5b5f-77f6-450d-b85a-2d57d870054c", "name": "9345b937-0745-4a39-8b8e-cca85f4d14b4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.839033632547656, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.36892018645953045, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6df4ee25-a6ea-4b19-9eeb-8e5124bd1fdf", "name": "335aa7fd-9a7a-43c0-94a5-69d03ad5089a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "86ef5b5f-77f6-450d-b85a-2d57d870054c"}}}]}, {"uuid": "475ac95f-30e7-4ab2-b9f6-97693f55195d", "name": "load_p1rlv798_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c30005d7-7e42-4a08-8935-0c7227fba4a6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6df4ee25-a6ea-4b19-9eeb-8e5124bd1fdf"}}}}, {"uuid": "27620e64-36f4-40ba-978e-de18bc4e532b", "name": "62e4942b-d3a0-498c-948a-12e3b7f8dcad_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.046232297850773, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7285366000251032, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cac38115-fa29-4a33-b1ef-955dc8b3b3f4", "name": "4ddf73be-47d5-41d8-a0af-f1089e7f3fa8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "27620e64-36f4-40ba-978e-de18bc4e532b"}}}]}, {"uuid": "ed1b18d9-960b-4b41-9994-578e21b4add9", "name": "load_p1rlv799_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f706d9d-0cb1-453b-9ca5-377f7d766099"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cac38115-fa29-4a33-b1ef-955dc8b3b3f4"}}}}, {"uuid": "58b99372-8eba-4bfd-9257-73cafdb761d2", "name": "fe6be4cf-f2be-4f13-9b0d-2925c42f365e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.046232297850773, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7285366000251032, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "09e0bc18-e092-4871-9310-559dd3979e4f", "name": "afbdf141-92fc-44c6-8829-317e342e3cd2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58b99372-8eba-4bfd-9257-73cafdb761d2"}}}]}, {"uuid": "191e9bea-c480-48d9-95bb-178ae994ab05", "name": "load_p1rlv799_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f706d9d-0cb1-453b-9ca5-377f7d766099"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "09e0bc18-e092-4871-9310-559dd3979e4f"}}}}, {"uuid": "cdc15692-4ad5-4014-a5ed-35a494709340", "name": "9a65e01b-2a25-4c33-9767-a0c5f3a169d9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2795803428770153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1698974287191981, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "30c757e1-f5f5-478f-8cfe-1b6a8ad5bf87", "name": "238dc65a-8496-493e-ba24-9caa91cdd716", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cdc15692-4ad5-4014-a5ed-35a494709340"}}}]}, {"uuid": "e20c0dc1-5195-4f50-8e05-0dd4080c5b83", "name": "load_p1rlv800_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3126c61-9602-45cf-8d57-27d26c14ca7e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "30c757e1-f5f5-478f-8cfe-1b6a8ad5bf87"}}}}, {"uuid": "f8b39291-b936-4c7e-a0c8-c43db1817944", "name": "7f80a2f3-4e2c-4048-bf17-54d0f67df2f1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2795803428770153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1698974287191981, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d540a418-a6ec-4518-bc0e-61fc04cc42b2", "name": "ae58a800-02f8-4f30-a632-f7d4f32f9846", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f8b39291-b936-4c7e-a0c8-c43db1817944"}}}]}, {"uuid": "4cbeba7c-b5dd-4e8f-bbee-7081b2b5b5f8", "name": "load_p1rlv800_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3126c61-9602-45cf-8d57-27d26c14ca7e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d540a418-a6ec-4518-bc0e-61fc04cc42b2"}}}}, {"uuid": "e25eb9c7-da87-4f68-9322-79e1381c82c9", "name": "4a7ac419-9d21-4faa-bf7a-df40e3c17cc5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2142575595505583, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8511261488468437, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c1b13cd-f503-4295-800a-46586da7cbaa", "name": "d29ba3ab-cbae-4437-9a3a-154ba2c85de5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e25eb9c7-da87-4f68-9322-79e1381c82c9"}}}]}, {"uuid": "d1a79f47-823e-489e-9102-bfd8661a0698", "name": "load_p1rlv801_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ecc45b2-1fbe-4a31-995f-e2f8fffe61a7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c1b13cd-f503-4295-800a-46586da7cbaa"}}}}, {"uuid": "7c34c779-171c-4a0e-9e87-e7988cb61122", "name": "0ab8dd7e-65d8-4fd1-a56e-86ebbc67d9a5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2142575595505583, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8511261488468437, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "620ff808-897f-4bb3-8cf6-1a3e02e6a00d", "name": "7b4b2a27-3f17-4c47-bda6-8f9c0aaf4e06", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7c34c779-171c-4a0e-9e87-e7988cb61122"}}}]}, {"uuid": "04816d23-d595-4b23-9d7c-736dd614d965", "name": "load_p1rlv801_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ecc45b2-1fbe-4a31-995f-e2f8fffe61a7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "620ff808-897f-4bb3-8cf6-1a3e02e6a00d"}}}}, {"uuid": "6a83fbb7-afe1-47d8-b2da-92214e07d67a", "name": "b078b8bf-7601-453e-a44d-d6208a434655_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.621947646480353, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0332384495271123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9b9deaaf-bc34-40fb-82b1-6502cd1d6393", "name": "c5ab4f42-4ac5-43ff-9588-89aa16263451", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6a83fbb7-afe1-47d8-b2da-92214e07d67a"}}}]}, {"uuid": "226177fd-fc5f-43d1-92ad-aa76bcd7f486", "name": "load_p1rlv802_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2436086-d5c4-4b70-a402-e7d1b6f5b77e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9b9deaaf-bc34-40fb-82b1-6502cd1d6393"}}}}, {"uuid": "edadc232-577f-4196-9c92-4982f9b32db8", "name": "a8b3a10b-50ff-4be6-b58b-612ba1efca1d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.621947646480353, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0332384495271123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f8c9d64d-a92c-4fab-a690-34c10f1e6876", "name": "de4abd99-b477-48f0-854d-a5de0fbab94f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "edadc232-577f-4196-9c92-4982f9b32db8"}}}]}, {"uuid": "5513bc2f-7647-49ad-acf0-cad7dc4344b8", "name": "load_p1rlv802_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2436086-d5c4-4b70-a402-e7d1b6f5b77e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f8c9d64d-a92c-4fab-a690-34c10f1e6876"}}}}, {"uuid": "4a6e72dc-0fd5-4a6d-a760-6bca463c7958", "name": "2d097c22-693f-465b-ab51-97c98658be1b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.991433457795887, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5982568468826307, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "93e40e12-3a0b-4142-b1b8-2798f6023a59", "name": "6324b962-f7ac-4458-92f4-14eff840fa9d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4a6e72dc-0fd5-4a6d-a760-6bca463c7958"}}}]}, {"uuid": "1a518b9a-23c3-404f-8aa6-9fef87d86748", "name": "load_p1rlv803_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "018c978c-5673-4090-9792-b75ee161f6d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "93e40e12-3a0b-4142-b1b8-2798f6023a59"}}}}, {"uuid": "f1d9e12c-3c70-4e12-b43a-42993ad845bf", "name": "4584a0d0-a1a7-4113-89fd-c3670eef0f71_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.991433457795887, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5982568468826307, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "13304da8-6eed-4a95-be24-9c06f1773a88", "name": "40305169-1355-4f4b-b05e-9a9f83d02553", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f1d9e12c-3c70-4e12-b43a-42993ad845bf"}}}]}, {"uuid": "4119dd23-3bfa-4b70-a7b2-b5cfe56c9ba1", "name": "load_p1rlv803_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "018c978c-5673-4090-9792-b75ee161f6d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "13304da8-6eed-4a95-be24-9c06f1773a88"}}}}, {"uuid": "c1fb01ee-0a2a-408e-b93d-63b1e0ae075c", "name": "0453fe34-a68d-4aa6-b3f3-f8be97681717_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.292799122473319, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5385753507809203, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f3134e33-7b18-431b-b107-337c262ecfb1", "name": "c1f9910b-dff3-4cd6-a77d-a29738ad9094", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c1fb01ee-0a2a-408e-b93d-63b1e0ae075c"}}}]}, {"uuid": "22899ffe-ad39-4be8-963a-658a3c025e92", "name": "load_p1rlv804_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a11ba246-99d9-4cf5-a557-bec53c75e6fb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f3134e33-7b18-431b-b107-337c262ecfb1"}}}}, {"uuid": "0577474f-713e-42a1-8360-6b5315691b7b", "name": "841c637a-f73e-4be3-851d-44ee71e33f7e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.292799122473319, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5385753507809203, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a70eccf7-9561-45ff-8e98-edcb8caddc1c", "name": "0bfa7b8d-3957-40b6-a517-47cc3bccd8c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0577474f-713e-42a1-8360-6b5315691b7b"}}}]}, {"uuid": "0d0dfa2c-b47a-4f09-894d-383a0abaa69f", "name": "load_p1rlv804_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a11ba246-99d9-4cf5-a557-bec53c75e6fb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a70eccf7-9561-45ff-8e98-edcb8caddc1c"}}}}, {"uuid": "cb90b3f2-2054-4a12-9bc1-174278764562", "name": "482d07e2-73a2-47d8-8077-9f733d11d325_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.987999469244499, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42543082019456707, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "02b2e4ae-c602-4a01-8dd0-8d4927f5c6bc", "name": "5f096ec6-979d-4f96-b37f-e4c023012d2c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cb90b3f2-2054-4a12-9bc1-174278764562"}}}]}, {"uuid": "94306602-9d91-4717-ac32-7601a7eec3a6", "name": "load_p1rlv805_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0475b34e-14ab-48e4-9df7-7444de1cde7d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "02b2e4ae-c602-4a01-8dd0-8d4927f5c6bc"}}}}, {"uuid": "e6faa0df-44b4-4ab4-918b-1ac3460b4f1a", "name": "354eb4e2-ce6d-4c16-bebc-38a7c83ac69b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.987999469244499, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42543082019456707, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9d416776-a183-456b-b3f3-1e4c13d23875", "name": "0e5a2587-eec9-45b4-b4aa-e20da2ae3c80", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e6faa0df-44b4-4ab4-918b-1ac3460b4f1a"}}}]}, {"uuid": "7f0817b8-99e8-4e61-bae4-015564a8978b", "name": "load_p1rlv805_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0475b34e-14ab-48e4-9df7-7444de1cde7d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9d416776-a183-456b-b3f3-1e4c13d23875"}}}}, {"uuid": "a1ae1f2a-6525-4488-8ddb-939e2c0a6bd9", "name": "86da67d3-dce4-40fa-924a-bfd2f591e54f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4950137537296666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31506625700854357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1176d2d0-4537-427d-99f7-59a44be17d94", "name": "db2b683a-b000-4b9c-9f6c-6fa3b027495e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a1ae1f2a-6525-4488-8ddb-939e2c0a6bd9"}}}]}, {"uuid": "09209c20-e17c-4675-b697-6afbacbb6e84", "name": "load_p1rlv806_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d9f269a-e476-4b82-a258-479d812d008d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1176d2d0-4537-427d-99f7-59a44be17d94"}}}}, {"uuid": "449e2e01-3cda-4040-bc51-39368c4a4046", "name": "a35047b0-fa29-4029-8d3a-5db7b73ea064_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4950137537296666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31506625700854357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7b3eeaba-f61b-4142-ae6e-89b24fce4547", "name": "a1528b96-8255-40de-8286-0171a4fe4581", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "449e2e01-3cda-4040-bc51-39368c4a4046"}}}]}, {"uuid": "dcc8b148-384f-4fa3-812b-52a49190219f", "name": "load_p1rlv806_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d9f269a-e476-4b82-a258-479d812d008d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7b3eeaba-f61b-4142-ae6e-89b24fce4547"}}}}, {"uuid": "71b51c74-d6e6-4e69-ac4a-677a95d0675a", "name": "21e2b630-e823-42b6-bf6d-863135e0c886_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.107858967059457, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3651352875232526, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ed616a72-ab12-4ce3-bace-d557ffc4cf34", "name": "e5242d07-16b8-465d-a1e4-90a257ee9cd7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "71b51c74-d6e6-4e69-ac4a-677a95d0675a"}}}]}, {"uuid": "fa476b20-630e-4d59-9f0f-a8d14a86554f", "name": "load_p1rlv807_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa259be8-8a61-461a-9e58-d4aaf1ce82db"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ed616a72-ab12-4ce3-bace-d557ffc4cf34"}}}}, {"uuid": "72f20477-33d2-4d5f-98ed-d5010b124c54", "name": "6ffe1ec2-6fcf-4f97-87fc-26865a0b7b7e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.107858967059457, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3651352875232526, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8b348d9f-802d-4db1-af83-c40d16a11169", "name": "54895934-cecc-4d92-8979-d00e62ba2e97", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72f20477-33d2-4d5f-98ed-d5010b124c54"}}}]}, {"uuid": "1d5c684d-9e7e-4e27-9f6c-89984f50cbb4", "name": "load_p1rlv807_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa259be8-8a61-461a-9e58-d4aaf1ce82db"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8b348d9f-802d-4db1-af83-c40d16a11169"}}}}, {"uuid": "10863d87-e2c5-4f8a-95c4-f779a208f6d2", "name": "cd9fef9d-a919-4b00-921e-8c2298a2343b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.847886228314274, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0445060168814917, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9d60dc14-18d9-41dc-bac8-1dc54d1cdd83", "name": "c37b3af4-0023-4302-82e0-be5197005d2b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "10863d87-e2c5-4f8a-95c4-f779a208f6d2"}}}]}, {"uuid": "c3bf69ee-2387-463a-a620-8889c6e696ed", "name": "load_p1rlv808_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dcb86a4-e6d7-48b4-b5c2-904635de271b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9d60dc14-18d9-41dc-bac8-1dc54d1cdd83"}}}}, {"uuid": "0ff26188-9f62-4401-8eaf-cfb058a40d76", "name": "f8daf638-4988-4e32-a558-2f17ccc10c4c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.847886228314274, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0445060168814917, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1108b691-7c26-477f-9c44-852d57e6c28a", "name": "36964797-4a01-4e6b-8193-17fdf9418144", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0ff26188-9f62-4401-8eaf-cfb058a40d76"}}}]}, {"uuid": "275d8b4b-180a-4ba5-8afe-6c5a984f910e", "name": "load_p1rlv808_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dcb86a4-e6d7-48b4-b5c2-904635de271b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1108b691-7c26-477f-9c44-852d57e6c28a"}}}}, {"uuid": "b90c43fd-9545-43d5-aa26-284f131d6951", "name": "fadbe899-067e-4fda-bd48-0fcb3363d23c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.739385174805638, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.976019322648958, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "861fff20-0acd-41c1-a98a-ffd197592db2", "name": "5c1659e7-028e-4567-bd50-da2566583a1d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b90c43fd-9545-43d5-aa26-284f131d6951"}}}]}, {"uuid": "9b75a966-d766-4da4-b3a9-99bb64317eaa", "name": "load_p1rlv809_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e0f8ee8-795f-4bea-bf7a-e2c477eefb89"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "861fff20-0acd-41c1-a98a-ffd197592db2"}}}}, {"uuid": "67a83380-fd27-4dbf-9f41-5025a8c30e9d", "name": "c4165a6b-63a1-4dbf-b432-ba5eb71b30bd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.739385174805638, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.976019322648958, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a2dcb90f-3ae2-411f-9321-5e5cf47b9fe9", "name": "1d108e2d-210d-4c1b-8fea-98eaaaac21cd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "67a83380-fd27-4dbf-9f41-5025a8c30e9d"}}}]}, {"uuid": "3f913e9e-d1c1-4fff-b236-303d44b401dc", "name": "load_p1rlv809_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e0f8ee8-795f-4bea-bf7a-e2c477eefb89"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a2dcb90f-3ae2-411f-9321-5e5cf47b9fe9"}}}}, {"uuid": "411f0651-0785-4e4f-99cc-b3715b12ea36", "name": "c1c6ca54-dd95-46f0-b798-4c803fd7167e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8309189378455104, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6069744647018672, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "03f741ce-96ad-4a1b-8277-ce411a51c68b", "name": "c368e4cc-7046-4395-bb00-5dce2f763b1b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "411f0651-0785-4e4f-99cc-b3715b12ea36"}}}]}, {"uuid": "28a09673-3ba1-4c43-9c43-3b7aa624b2a8", "name": "load_p1rlv810_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb4a881f-684d-48e4-a6f0-5832f73d140a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "03f741ce-96ad-4a1b-8277-ce411a51c68b"}}}}, {"uuid": "7901af69-6f57-4a73-b623-9e63c9300013", "name": "d8d7a554-5a06-4356-8cd0-15d4eb3e4a88_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8309189378455104, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6069744647018672, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f103a8ea-9301-4fda-81c7-a2f0b00444ea", "name": "0c4a7bcb-a22e-4fa1-abc1-71508477e6a6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7901af69-6f57-4a73-b623-9e63c9300013"}}}]}, {"uuid": "9704a4db-8a6e-4150-a7a1-4434d753063b", "name": "load_p1rlv810_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb4a881f-684d-48e4-a6f0-5832f73d140a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f103a8ea-9301-4fda-81c7-a2f0b00444ea"}}}}, {"uuid": "58540381-46f0-4842-b1f7-6f12c33c1aaa", "name": "3a3f1738-9558-40b1-803f-36ade87a88d0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7362273540893955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24527287728713068, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "535428b8-7298-4e27-8f95-a29be5db7f75", "name": "69a403d1-f846-495a-8ee7-1090e160611e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58540381-46f0-4842-b1f7-6f12c33c1aaa"}}}]}, {"uuid": "6aa9335f-11aa-4850-b488-a3b57ff0810c", "name": "load_p1rlv811_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "052949b1-9e85-4be7-993c-9e97efda3657"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "535428b8-7298-4e27-8f95-a29be5db7f75"}}}}, {"uuid": "d8097276-eed1-4787-91df-157c2fe5246c", "name": "74da4ae4-969e-4389-ba97-5e937297c4b4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7362273540893955, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24527287728713068, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ff4d4f14-c6e8-4311-97fb-9a84145923c4", "name": "590a0c92-c812-41de-ae77-37676b1dd971", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d8097276-eed1-4787-91df-157c2fe5246c"}}}]}, {"uuid": "5e75c977-5c96-49b7-b33e-bd0dddd5db3b", "name": "load_p1rlv811_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "052949b1-9e85-4be7-993c-9e97efda3657"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ff4d4f14-c6e8-4311-97fb-9a84145923c4"}}}}, {"uuid": "d9c9c1f7-9a73-43ad-89bd-318929ad3ab7", "name": "1069ede5-9826-4402-8e4a-ceb7acb95f5b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0599252267318962, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3748861224482183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50152347-5bdb-49be-b9e0-01759af6ed74", "name": "b2bf3543-58fa-4099-9477-15cd1ff1a0b7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d9c9c1f7-9a73-43ad-89bd-318929ad3ab7"}}}]}, {"uuid": "82dea5fe-cd3a-42bd-a5f2-9d088a939774", "name": "load_p1rlv812_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26fea867-af5f-4213-b9c3-487975d1285e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50152347-5bdb-49be-b9e0-01759af6ed74"}}}}, {"uuid": "4c83845b-74b7-4ab5-8191-373fe40720fd", "name": "6faaffee-3331-4355-aa1e-1c718446170d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0599252267318962, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3748861224482183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "667a104b-536d-42cb-816c-35a837cf2f9c", "name": "f4293f81-a29c-4b0d-9b5e-0819f2ea6af3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4c83845b-74b7-4ab5-8191-373fe40720fd"}}}]}, {"uuid": "d01e44be-07f1-4f33-9f4d-b8b64c9f8c4e", "name": "load_p1rlv812_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26fea867-af5f-4213-b9c3-487975d1285e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "667a104b-536d-42cb-816c-35a837cf2f9c"}}}}, {"uuid": "74c8e1af-8f80-4b63-8126-b89b014016fe", "name": "80123125-5b25-452c-aa68-8772e6db11d1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7457942211533133, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8784341351558463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bc2a2099-56de-42de-8494-e78cc7abf913", "name": "3f111631-2636-4a5d-95d6-45a74a6c73c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "74c8e1af-8f80-4b63-8126-b89b014016fe"}}}]}, {"uuid": "c527ba67-9ea4-4e8e-b824-7e21912984ae", "name": "load_p1rlv813_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10d44b60-55c0-4d78-abbb-52c8cd67134b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bc2a2099-56de-42de-8494-e78cc7abf913"}}}}, {"uuid": "76e54313-3a38-4657-9e11-ca3a54a65c86", "name": "6e582f0d-b6ca-41f6-9d92-3c66c8efced8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7457942211533133, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8784341351558463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7bd4b1d3-e002-4251-8d5f-b1ab9b73ea9f", "name": "2547f8ca-a395-4e67-854e-078bfad68612", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "76e54313-3a38-4657-9e11-ca3a54a65c86"}}}]}, {"uuid": "020e8cbe-3954-4821-8e3a-e5aeec53bd36", "name": "load_p1rlv813_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10d44b60-55c0-4d78-abbb-52c8cd67134b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7bd4b1d3-e002-4251-8d5f-b1ab9b73ea9f"}}}}, {"uuid": "58ad71a3-0c2d-44a6-b0ee-7505907d451c", "name": "852e816c-ea4f-467b-8a6e-39eccd098c5c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.559104904760759, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9054328372998879, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "67877123-5ca0-4a19-a3b5-dd96d917765e", "name": "4a6c75be-9ab3-4470-b580-fb976de83b81", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58ad71a3-0c2d-44a6-b0ee-7505907d451c"}}}]}, {"uuid": "35d25ebf-a90f-48cc-8646-7ffa7626e103", "name": "load_p1rlv814_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b8065f3-8286-4f99-aa56-b9b631a2f838"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "67877123-5ca0-4a19-a3b5-dd96d917765e"}}}}, {"uuid": "bc3882ff-f092-48c8-bfeb-1052dde4966e", "name": "12d12581-ea08-41f0-971d-8554dadfd08d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.559104904760759, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9054328372998879, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0280bd4b-f7b8-455d-b020-1545d7160332", "name": "a5919842-32a2-4d76-9d02-bdb0b1001d6f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bc3882ff-f092-48c8-bfeb-1052dde4966e"}}}]}, {"uuid": "64cf4715-7576-460b-a418-5f1026488522", "name": "load_p1rlv814_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b8065f3-8286-4f99-aa56-b9b631a2f838"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0280bd4b-f7b8-455d-b020-1545d7160332"}}}}, {"uuid": "16ea51e7-cc44-48d1-ae9b-8225235d9388", "name": "0614d656-6794-4b42-b0fc-736838c79079_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5424601784243566, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31457775613808403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0bba08a5-c480-4c68-91bd-ee13541689d4", "name": "d5448476-a6b8-4f95-9116-644f14416659", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "16ea51e7-cc44-48d1-ae9b-8225235d9388"}}}]}, {"uuid": "f74b3e0a-a07f-41e6-aebd-8ab1b254bb5b", "name": "load_p1rlv815_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a134556-828b-4e0c-8773-2f207802e33a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0bba08a5-c480-4c68-91bd-ee13541689d4"}}}}, {"uuid": "ad0b2281-280e-4076-8064-667a6d21ed4f", "name": "de19320e-a7de-4eb0-99aa-bfe8567f4a97_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5424601784243566, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31457775613808403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f2d71091-b353-43e0-8aa5-403a8f7cb0b4", "name": "4275bf63-4eb4-4851-96cb-99b331938601", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ad0b2281-280e-4076-8064-667a6d21ed4f"}}}]}, {"uuid": "6e68ad30-1e54-48c4-91e8-bf82491286e3", "name": "load_p1rlv815_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a134556-828b-4e0c-8773-2f207802e33a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f2d71091-b353-43e0-8aa5-403a8f7cb0b4"}}}}, {"uuid": "cc6a60b4-daec-4a6e-9d12-9ae8392dd142", "name": "63c541fe-b2e0-4195-add5-1638ee13af84_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.357764823379774, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7869023210214492, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b2886171-89c1-477c-83a0-d51f6cb7b994", "name": "3bf69e6f-2184-4351-891b-529fb58f8505", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cc6a60b4-daec-4a6e-9d12-9ae8392dd142"}}}]}, {"uuid": "1d166bab-8038-4240-bd6a-990676496f71", "name": "load_p1rlv816_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d6de7c2-fd2c-4071-8e90-1513f521cf87"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b2886171-89c1-477c-83a0-d51f6cb7b994"}}}}, {"uuid": "29adaec0-7aae-48a3-ab81-8e9adb2b7dd8", "name": "5b8fe093-71c0-4840-b92f-1c8335949f70_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.357764823379774, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7869023210214492, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "edc520af-667a-4ee9-b69c-602f2ee46cd9", "name": "57027629-6e91-4bed-bfee-cbdba2e2ee83", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "29adaec0-7aae-48a3-ab81-8e9adb2b7dd8"}}}]}, {"uuid": "f806dba9-9864-4a17-98e6-8c7e5e404f25", "name": "load_p1rlv816_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d6de7c2-fd2c-4071-8e90-1513f521cf87"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "edc520af-667a-4ee9-b69c-602f2ee46cd9"}}}}, {"uuid": "40ec427d-4957-4781-9f16-defc4fee8c6c", "name": "275b825d-0d85-47d5-80e1-e7f977a40dcb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1206689642843692, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34257205075767067, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f2e22e49-ad98-46fc-b3f6-b9815b9ab095", "name": "2c11f1b6-aa7c-40a6-b8b2-4e732406033b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "40ec427d-4957-4781-9f16-defc4fee8c6c"}}}]}, {"uuid": "75abaeea-16a0-4cc7-aec6-20c6a7b98961", "name": "load_p1rlv817_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11064c6f-3b7a-43b5-96ca-7ef96be3815e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f2e22e49-ad98-46fc-b3f6-b9815b9ab095"}}}}, {"uuid": "fdebb9b4-7dad-44e1-89fa-07845bbeafad", "name": "55c9250e-e64e-4954-8dbf-d93791a576e9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1206689642843692, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34257205075767067, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aae121fb-b12e-4312-b17b-f4a5fe5a6853", "name": "04384dfc-7214-4f2b-b449-060dc7a9c122", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fdebb9b4-7dad-44e1-89fa-07845bbeafad"}}}]}, {"uuid": "4c88d4b3-eeee-49c9-8200-c22d72a7e5c1", "name": "load_p1rlv817_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11064c6f-3b7a-43b5-96ca-7ef96be3815e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aae121fb-b12e-4312-b17b-f4a5fe5a6853"}}}}, {"uuid": "6cfcc2d1-35cc-4487-9fad-d776a52e44a4", "name": "546d460b-d910-4839-bab8-8fa5e7633188_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6669289783709, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.056901546523703654, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "03355bda-6ec3-41d7-bd7e-561878806338", "name": "7515a17d-db96-49cb-92eb-82f1034f0bfb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6cfcc2d1-35cc-4487-9fad-d776a52e44a4"}}}]}, {"uuid": "4dfc5955-660e-4595-a330-c040395a985c", "name": "load_p1rlv818_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd8c54fd-14d4-46fa-8bef-59c1097d5026"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "03355bda-6ec3-41d7-bd7e-561878806338"}}}}, {"uuid": "22c85500-9369-41ae-b2fd-df9cf5491168", "name": "c0d8a78f-2c84-47e6-a6f1-4539baf2a4c1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6669289783709, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.056901546523703654, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5ec7b202-9be4-4f06-90dd-c373fd66e271", "name": "18450587-18dd-495a-b503-26c3b7666697", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "22c85500-9369-41ae-b2fd-df9cf5491168"}}}]}, {"uuid": "5b11581f-6f3b-4e07-9631-582873c4ad2d", "name": "load_p1rlv818_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd8c54fd-14d4-46fa-8bef-59c1097d5026"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5ec7b202-9be4-4f06-90dd-c373fd66e271"}}}}, {"uuid": "29b9d5df-74fd-4d30-b8db-b1dc6baf59c5", "name": "700c68e8-f6bd-4e87-83ee-f0234d7744c5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.195601026095605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4379463760124337, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fe86b1ac-9749-4799-8245-57e5a38f23cb", "name": "01909453-2a47-428b-95f7-da66d28dbf70", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "29b9d5df-74fd-4d30-b8db-b1dc6baf59c5"}}}]}, {"uuid": "89ca12ad-7ca6-44eb-844b-402ac986d9ed", "name": "load_p1rlv819_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "def7e507-cb62-42f5-8451-b8a742ef4eb2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fe86b1ac-9749-4799-8245-57e5a38f23cb"}}}}, {"uuid": "2c2b7e63-bd59-4911-9dff-b60fb2ca9df0", "name": "9d2c38c2-cc88-474b-97b5-d32bf1220fb9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.195601026095605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4379463760124337, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9d7081f1-3610-4720-83ee-674d84afb519", "name": "deb735ed-88c7-483c-972c-ef5226dc0706", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2c2b7e63-bd59-4911-9dff-b60fb2ca9df0"}}}]}, {"uuid": "2360163a-c6ae-4a56-8b0f-268bf5d7f355", "name": "load_p1rlv819_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "def7e507-cb62-42f5-8451-b8a742ef4eb2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9d7081f1-3610-4720-83ee-674d84afb519"}}}}, {"uuid": "359e99f9-c749-4a63-9430-3d7d1687bf3a", "name": "dc8fcfe6-1b8d-4b27-9304-228eafb3bea7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.008167500419157, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.871384812064858, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "08081de5-092d-418d-8bf1-7a0776a98115", "name": "d6882342-2d99-4ee8-8620-51e18126df5d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "359e99f9-c749-4a63-9430-3d7d1687bf3a"}}}]}, {"uuid": "61583365-45ef-467f-bb32-f91025a8734e", "name": "load_p1rlv820_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41e1e576-4cc9-4fea-9d87-d436f000a675"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "08081de5-092d-418d-8bf1-7a0776a98115"}}}}, {"uuid": "2069248f-6ee1-48af-aef7-8148d4d28b60", "name": "f63716d2-ce08-4e7a-984e-76afa17927f9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.008167500419157, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.871384812064858, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2f52cef4-03b0-41b0-9cd8-e2ac77c6d1ca", "name": "f96170a8-efbe-4507-b6e8-ecf270701de9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2069248f-6ee1-48af-aef7-8148d4d28b60"}}}]}, {"uuid": "c8915dd6-3369-4fb4-acb5-5a4cd2081813", "name": "load_p1rlv820_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41e1e576-4cc9-4fea-9d87-d436f000a675"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2f52cef4-03b0-41b0-9cd8-e2ac77c6d1ca"}}}}, {"uuid": "924ed092-c747-45a6-83f1-d75008562baf", "name": "e48461e1-8dc1-479e-b509-d84abb5c5a92_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4363904318707768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7717292253609904, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3f825a39-24df-424e-9e0a-f0438f84d933", "name": "77fe357d-9cfb-4a07-82ac-389991596cde", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "924ed092-c747-45a6-83f1-d75008562baf"}}}]}, {"uuid": "516e8fd2-c4d4-49cd-b34a-7d09cbed8e5c", "name": "load_p1rlv821_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5578d8b4-7c1e-444f-8d27-8c9bf733f420"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3f825a39-24df-424e-9e0a-f0438f84d933"}}}}, {"uuid": "625516ba-61e6-4261-a54c-2f53d81cb1e4", "name": "43a1433d-0afd-42b1-988d-c93b6e2936e8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4363904318707768, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7717292253609904, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "93d746a0-40ed-4eeb-a100-03d3b7d228dd", "name": "efadacd5-7018-4c44-8c40-90ffd6627a3e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "625516ba-61e6-4261-a54c-2f53d81cb1e4"}}}]}, {"uuid": "025864c7-1d2b-4f23-a563-57f117b54b95", "name": "load_p1rlv821_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5578d8b4-7c1e-444f-8d27-8c9bf733f420"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "93d746a0-40ed-4eeb-a100-03d3b7d228dd"}}}}, {"uuid": "9f385489-470c-4e4f-82ec-3e20b74fd3df", "name": "c396dca3-3bd5-4b66-8636-2b783f47eabc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3307696614484872, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.07740524652130432, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b108c76f-15e9-4990-af33-62b7addf308b", "name": "69701d81-85c2-43f5-be5e-bee3f7404249", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9f385489-470c-4e4f-82ec-3e20b74fd3df"}}}]}, {"uuid": "8382cc38-6044-45e3-9e0d-62ddfd873277", "name": "load_p1rlv822_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7ce197c-cee4-40df-b1d7-be13f1be8bb1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b108c76f-15e9-4990-af33-62b7addf308b"}}}}, {"uuid": "dd3e4e3a-3559-4027-afba-d627613059c6", "name": "21d52caf-ca54-492b-bc47-fa637a275d66_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3307696614484872, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.07740524652130432, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ba7bb2be-efad-4c03-8020-82c7b135863b", "name": "43163c38-efba-4c0e-9669-cef371ff9323", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dd3e4e3a-3559-4027-afba-d627613059c6"}}}]}, {"uuid": "1e56c001-43d9-4ef4-aa50-f82a1f42232d", "name": "load_p1rlv822_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7ce197c-cee4-40df-b1d7-be13f1be8bb1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ba7bb2be-efad-4c03-8020-82c7b135863b"}}}}, {"uuid": "43c1785d-9bed-4a42-877f-ad25a083d32e", "name": "de719e1f-e982-40a1-9d77-d4931c9ef1fe_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.396349422902612, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13402564403017767, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e5a93594-c464-46e5-94e3-ee0e9672a6f4", "name": "e81a1162-8c21-42ce-8159-51bf411564ae", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "43c1785d-9bed-4a42-877f-ad25a083d32e"}}}]}, {"uuid": "c6e5319e-9f6a-411c-af04-8f7bcbd5054c", "name": "load_p1rlv823_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81802469-7320-47e9-b826-fbb33bd371ab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e5a93594-c464-46e5-94e3-ee0e9672a6f4"}}}}, {"uuid": "732af354-3640-4143-8ab9-7f60cd75a7cb", "name": "67f449d4-29d0-41e9-926a-721a49b03abe_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.396349422902612, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13402564403017767, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e9e0b6ba-dd5c-4271-b788-e17debd0e9c1", "name": "99758b48-4b27-4629-9166-a329db484aa3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "732af354-3640-4143-8ab9-7f60cd75a7cb"}}}]}, {"uuid": "e28c0ad6-88fe-40ff-a288-8d5abdb44e54", "name": "load_p1rlv823_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81802469-7320-47e9-b826-fbb33bd371ab"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e9e0b6ba-dd5c-4271-b788-e17debd0e9c1"}}}}, {"uuid": "ae0714a0-73be-4bae-8c83-bc9c9fa06ecf", "name": "6dcc93be-02a0-41ac-967f-e1079869c476_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2520868864654517, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.447133871274774, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7a24802e-526b-47a6-9ca6-2663b791840e", "name": "fd57d0f7-5105-4000-a96c-fa2643f11a48", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ae0714a0-73be-4bae-8c83-bc9c9fa06ecf"}}}]}, {"uuid": "7481a3f9-8384-48c9-9635-ee667876d70b", "name": "load_p1rlv824_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20ce76b6-9305-4525-b77e-b7300edc2c81"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7a24802e-526b-47a6-9ca6-2663b791840e"}}}}, {"uuid": "02a872db-8965-4030-be6c-e5eba07a0186", "name": "3bc89a2e-df99-411e-bfd7-7b60f6a0df53_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2520868864654517, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.447133871274774, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2d7c4db9-f57c-4683-9f7a-326a08a232cb", "name": "273da339-2e96-45f0-bf5a-361c5fabb759", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "02a872db-8965-4030-be6c-e5eba07a0186"}}}]}, {"uuid": "2da7ec48-a219-4860-b157-b952d788b1fd", "name": "load_p1rlv824_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20ce76b6-9305-4525-b77e-b7300edc2c81"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2d7c4db9-f57c-4683-9f7a-326a08a232cb"}}}}, {"uuid": "c25e60ea-748b-4dc8-91bd-11ba47a59b90", "name": "7705d927-687f-472f-9f3f-97f76e32d931_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.107858967059457, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3651352875232526, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ed082447-de8b-4db0-bcac-8321cd5b5865", "name": "dc510fb5-a27f-499e-aec2-85cfc57e665c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c25e60ea-748b-4dc8-91bd-11ba47a59b90"}}}]}, {"uuid": "1f09f953-cee0-45a4-a758-5408113a1b67", "name": "load_p1rlv825_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d209dff6-7a24-41ef-947a-8c6f79c2d65c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ed082447-de8b-4db0-bcac-8321cd5b5865"}}}}, {"uuid": "b148e492-bf6a-4644-97ab-97692805a008", "name": "4c356a34-1433-4277-8245-e8dd31188a15_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.107858967059457, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3651352875232526, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bd5e69ea-8e7b-4aa2-a197-465d10b3de6c", "name": "a23ea15f-02e5-4161-83df-0f68f951e1f5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b148e492-bf6a-4644-97ab-97692805a008"}}}]}, {"uuid": "2eae6474-5984-44cd-b557-74368e1ba0e5", "name": "load_p1rlv825_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d209dff6-7a24-41ef-947a-8c6f79c2d65c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bd5e69ea-8e7b-4aa2-a197-465d10b3de6c"}}}}, {"uuid": "6c33c342-8e5a-488a-b638-33e7ed70acb4", "name": "4d3811cd-4607-4ed9-b2a6-97940954c71a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.253869376169332, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.6228339639204339, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ce4c46dc-0f47-4985-bcbb-c278f75f57e5", "name": "820dcb99-deb3-45f7-8924-45da135769cc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c33c342-8e5a-488a-b638-33e7ed70acb4"}}}]}, {"uuid": "e1d6bb83-68ec-4e1c-8e31-96aaa50a140b", "name": "load_p1rlv826_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06746d4d-3db8-45b1-888e-d3d9e405ccaf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ce4c46dc-0f47-4985-bcbb-c278f75f57e5"}}}}, {"uuid": "a561e955-6cdb-4877-92b3-76a511ec69dd", "name": "6907b347-f27e-4119-81ce-258996b075ab_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.253869376169332, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.6228339639204339, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4d9d58e4-826f-4533-976a-07a74519c72c", "name": "5336a82c-6365-4ec0-808d-6e5f1c778f25", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a561e955-6cdb-4877-92b3-76a511ec69dd"}}}]}, {"uuid": "57fb6b3f-38b0-4c6b-896e-e458a17c2e13", "name": "load_p1rlv826_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06746d4d-3db8-45b1-888e-d3d9e405ccaf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4d9d58e4-826f-4533-976a-07a74519c72c"}}}}, {"uuid": "59863883-9c7c-4105-aad3-649bc7f1c86c", "name": "42a04cbe-98b1-4573-bbdb-a4ed8fefdb84_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7037919474579788, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6943112548118018, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a0da3511-7362-46bb-ad2b-e10a83884207", "name": "ba8319d8-b6c4-4d55-8ecd-2d7863eaa07c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "59863883-9c7c-4105-aad3-649bc7f1c86c"}}}]}, {"uuid": "97e3d9fc-8e5e-4414-b212-0538210a1add", "name": "load_p1rlv827_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c89db91-40fe-4de6-973e-5d8c23e35080"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a0da3511-7362-46bb-ad2b-e10a83884207"}}}}, {"uuid": "983a7419-bc91-4c68-9e29-fbe68f06fe48", "name": "1f6e40aa-31bc-4190-91b8-d783c587d4fe_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7037919474579788, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6943112548118018, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a361842b-d762-4198-ade6-c746a872ea4f", "name": "30b629ce-6a69-4159-996f-c797e585ae37", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "983a7419-bc91-4c68-9e29-fbe68f06fe48"}}}]}, {"uuid": "06acf64c-354f-444c-bf0c-99db6ed05d02", "name": "load_p1rlv827_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c89db91-40fe-4de6-973e-5d8c23e35080"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a361842b-d762-4198-ade6-c746a872ea4f"}}}}, {"uuid": "c0da35c7-38c3-4a5f-b49c-fd926354dc45", "name": "629fac6e-d544-4445-869f-cd6d0ef5e52c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8668291909105112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7572719732007044, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7fd263c3-70d0-417c-9a9f-204208d60db4", "name": "40370cd1-6e63-4ebf-a139-9431d9e4f6a0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c0da35c7-38c3-4a5f-b49c-fd926354dc45"}}}]}, {"uuid": "0667d89d-8655-4719-910e-b5c90e028e24", "name": "load_p1rlv828_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08c3f5ef-c2d5-4ce2-8fc7-b665d8cbbab6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7fd263c3-70d0-417c-9a9f-204208d60db4"}}}}, {"uuid": "cc6c55e1-5bfe-48df-8608-a17fa1321933", "name": "3959c432-385d-4a8d-89c9-41cd743eb8ca_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8668291909105112, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7572719732007044, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "214e9093-d512-4c67-bf8a-ef70b8086f41", "name": "cbd2b3d4-fd43-4096-8e91-63b2907967d8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cc6c55e1-5bfe-48df-8608-a17fa1321933"}}}]}, {"uuid": "ea5bcc31-c953-4505-8c46-60511b2f876e", "name": "load_p1rlv828_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08c3f5ef-c2d5-4ce2-8fc7-b665d8cbbab6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "214e9093-d512-4c67-bf8a-ef70b8086f41"}}}}, {"uuid": "7ad6bc0c-b62f-44ae-9c37-ab3b4052d7c8", "name": "f30d3093-c727-47e3-baba-93875c057f3e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7400090938863744, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.257745187793523, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "401a8519-192c-42da-a41a-bdad27ed8419", "name": "0aa20863-91fe-49fe-a3ed-41231982e601", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7ad6bc0c-b62f-44ae-9c37-ab3b4052d7c8"}}}]}, {"uuid": "0ff83211-0502-4e70-a369-18a16f4ae90c", "name": "load_p1rlv829_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e3a1bd0-69fe-42bb-993d-2094ecc658ce"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "401a8519-192c-42da-a41a-bdad27ed8419"}}}}, {"uuid": "a4bf3895-2bb5-4ee3-8cfe-2e09c907fd8c", "name": "e6fa068a-bf15-4d7d-8332-e191453e2acd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7400090938863744, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.257745187793523, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eb8fdc59-30ac-483d-9df4-0dec6bb85ceb", "name": "7740e9e8-162d-4b41-8c1a-212cea502eb9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a4bf3895-2bb5-4ee3-8cfe-2e09c907fd8c"}}}]}, {"uuid": "299e04bb-1d60-423e-8d18-56645cf724fc", "name": "load_p1rlv829_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e3a1bd0-69fe-42bb-993d-2094ecc658ce"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eb8fdc59-30ac-483d-9df4-0dec6bb85ceb"}}}}, {"uuid": "91821f0d-42c1-443d-bab5-f4dbfa137736", "name": "6d6ba518-b330-41aa-8db4-9eee5d01dcf6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9541125560071345, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3732603805546264, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9608867c-46ad-4f6e-bad2-a4ebf473085b", "name": "03eaea5d-cfcd-4011-9944-96a383b5746f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "91821f0d-42c1-443d-bab5-f4dbfa137736"}}}]}, {"uuid": "b9160f40-3f3a-4063-b2c5-28972fb67dcc", "name": "load_p1rlv830_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b7538477-32ab-4db6-872d-83be7ec89fd9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9608867c-46ad-4f6e-bad2-a4ebf473085b"}}}}, {"uuid": "faae66b1-94b7-4b3f-a513-844e1d4e3b59", "name": "d939b1ac-1f94-4ebf-833e-d6c7748a8701_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9541125560071345, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3732603805546264, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "22ba8929-046b-4dda-a245-91697081fac6", "name": "b88128e3-e68d-4911-a40b-e6b57028509d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "faae66b1-94b7-4b3f-a513-844e1d4e3b59"}}}]}, {"uuid": "c080c3d3-8276-4554-85db-b92e863ffa05", "name": "load_p1rlv830_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b7538477-32ab-4db6-872d-83be7ec89fd9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "22ba8929-046b-4dda-a245-91697081fac6"}}}}, {"uuid": "610b56f9-d801-45ae-91db-df6cf2d35a48", "name": "853c8726-a620-4d7a-90e1-56e680eb8707_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.746284303820433, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6724067157838972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5ef1cd69-1981-4100-ae90-f109a7a00c4e", "name": "e3db4086-7eaf-4569-aff4-b6855d4845ff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "610b56f9-d801-45ae-91db-df6cf2d35a48"}}}]}, {"uuid": "717c1f69-4334-47b0-9273-fe51d52e1411", "name": "load_p1rlv831_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4b6c4e-78d0-4c8e-907c-619f1e43c149"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5ef1cd69-1981-4100-ae90-f109a7a00c4e"}}}}, {"uuid": "67766f61-4a1d-4ae4-949d-345e1fa00a3b", "name": "f577a9b9-c12a-4073-8d3b-edfaeceec0a7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.746284303820433, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6724067157838972, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b309dd9b-3303-4986-bf5d-7b6a9125fbfa", "name": "30b217c3-5083-4f0f-83d1-5a83ff59cdec", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "67766f61-4a1d-4ae4-949d-345e1fa00a3b"}}}]}, {"uuid": "a9025d91-ecf5-40e7-a428-35f87c18338b", "name": "load_p1rlv831_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4b6c4e-78d0-4c8e-907c-619f1e43c149"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b309dd9b-3303-4986-bf5d-7b6a9125fbfa"}}}}, {"uuid": "afc3c4de-ab14-43a4-8d9e-9707108c6cb5", "name": "6bee1ada-96fe-4d3d-81f5-c1d0a73bad25_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.250267265771566, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8009319586825154, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ac573839-6e5c-4f36-9a7b-539fa20cd575", "name": "d8c6d513-2c81-4cfe-a307-6e39d448e951", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "afc3c4de-ab14-43a4-8d9e-9707108c6cb5"}}}]}, {"uuid": "0b4ab97a-46d5-4222-be17-9a01904cb32e", "name": "load_p1rlv832_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10373c0d-6a3c-4160-a174-22de447d4c38"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ac573839-6e5c-4f36-9a7b-539fa20cd575"}}}}, {"uuid": "7229411d-e4f1-4f2b-99a0-e7ba1ae18b31", "name": "35c3f57a-bf1f-413d-ad43-41a74ca34e27_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.250267265771566, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8009319586825154, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8b0cd29d-184f-4521-ad39-ea089bf07926", "name": "24c33887-3572-4423-9d5b-cdf7de2cbe5b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7229411d-e4f1-4f2b-99a0-e7ba1ae18b31"}}}]}, {"uuid": "7ba46c6f-ba1c-47d7-9b7a-06e1e5719ae1", "name": "load_p1rlv832_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10373c0d-6a3c-4160-a174-22de447d4c38"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8b0cd29d-184f-4521-ad39-ea089bf07926"}}}}, {"uuid": "9e1344e8-665f-4802-bc78-adc16aec041a", "name": "2bccc6c8-546c-4581-b75f-badf5b5cb7d4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1212324580541053, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5100712782164012, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2651276c-e3e2-4864-afc8-1da4343802b9", "name": "f3efb4cd-794e-4529-9c3c-341c54217828", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9e1344e8-665f-4802-bc78-adc16aec041a"}}}]}, {"uuid": "21b607ba-0654-4239-be2d-fadce2328dd7", "name": "load_p1rlv833_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eb57fc4-636d-4923-9f4a-d308b062599f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2651276c-e3e2-4864-afc8-1da4343802b9"}}}}, {"uuid": "f12af18a-47fa-47d1-a761-95ec62686d35", "name": "9886c5ae-49a6-4fa0-b833-409938e3701e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1212324580541053, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5100712782164012, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "49bcbe3a-fe71-406c-a18b-38410946c071", "name": "624ef648-caab-4363-9633-a4af7656fbae", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f12af18a-47fa-47d1-a761-95ec62686d35"}}}]}, {"uuid": "3dfe3a27-efa3-4260-a84f-c3af41c6c947", "name": "load_p1rlv833_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eb57fc4-636d-4923-9f4a-d308b062599f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "49bcbe3a-fe71-406c-a18b-38410946c071"}}}}, {"uuid": "828de88b-2da7-4949-a09d-a7e48e037427", "name": "fe52519e-3b08-4cdc-8dff-5c6c8dea6a26_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.107858967059457, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3651352875232526, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f2fbfcd4-8d69-47a6-af51-318cfac95969", "name": "1c968931-2b64-4deb-8271-85610cbaf286", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "828de88b-2da7-4949-a09d-a7e48e037427"}}}]}, {"uuid": "0d46b9b6-70f9-43ca-8440-b4e9bad211fa", "name": "load_p1rlv834_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d437c83c-cbd1-41bf-b455-21123e82d59f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f2fbfcd4-8d69-47a6-af51-318cfac95969"}}}}, {"uuid": "15c45dba-5e69-4c70-b57e-2ee55683f89b", "name": "bce8a9a9-d325-4088-bed5-f1e9efafb067_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.107858967059457, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3651352875232526, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b25d3f8b-b0bc-49a0-bbc9-2b0517ac3c39", "name": "04c293e5-c570-4ee9-be1c-98e3b93fcdd0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "15c45dba-5e69-4c70-b57e-2ee55683f89b"}}}]}, {"uuid": "56510e77-31ae-4502-8883-767e359af33c", "name": "load_p1rlv834_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d437c83c-cbd1-41bf-b455-21123e82d59f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b25d3f8b-b0bc-49a0-bbc9-2b0517ac3c39"}}}}, {"uuid": "308e0b97-6215-4e63-aecc-72d5a156ebd0", "name": "b591c622-741a-4b41-966e-7b0e3ac368f4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1426015471760884, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5928311844731246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "646a7475-4643-4898-805a-75f320668a09", "name": "7680aef7-bdbe-4eed-89a3-72d8d86ee122", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "308e0b97-6215-4e63-aecc-72d5a156ebd0"}}}]}, {"uuid": "f54d8273-6c0f-48c5-9266-581a386820c2", "name": "load_p1rlv835_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bc35476-5839-4095-bea5-36e32450b890"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "646a7475-4643-4898-805a-75f320668a09"}}}}, {"uuid": "a9b9efc3-5b10-4a82-ae2f-6772a746aa4d", "name": "7c4c87bf-59d0-4f19-a53d-841f529cb164_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1426015471760884, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5928311844731246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "657e4375-2b1e-420b-8447-a12cd7246c24", "name": "e6529a33-34f4-4c52-920d-4fbf92b78d5d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a9b9efc3-5b10-4a82-ae2f-6772a746aa4d"}}}]}, {"uuid": "8858b368-17f9-43a7-895a-67d5d3a09b35", "name": "load_p1rlv835_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bc35476-5839-4095-bea5-36e32450b890"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "657e4375-2b1e-420b-8447-a12cd7246c24"}}}}, {"uuid": "6b543206-afcc-4053-af5a-60eae057d2dd", "name": "9f53b4f5-d81a-4842-bb37-dab765efb4a0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.941898785419248, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8498359578625553, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "17c99f84-2e3f-4355-afd0-0e5d869deccb", "name": "9bd960e5-1579-4c69-a241-2c964d985a09", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6b543206-afcc-4053-af5a-60eae057d2dd"}}}]}, {"uuid": "625a15f2-f4b1-4664-becf-522994dfcc67", "name": "load_p1rlv836_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12556ab7-c50a-4624-9d84-b85585822245"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "17c99f84-2e3f-4355-afd0-0e5d869deccb"}}}}, {"uuid": "18b48cec-54f1-4030-8722-dc2c86f02589", "name": "bb4b9f21-c379-4328-9541-8879c5c3f1e8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.941898785419248, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8498359578625553, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5f7fb70e-fa24-40c4-b113-ee644f4111bd", "name": "424ea7c6-2b33-4b83-88f3-23b0ef04e6d9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "18b48cec-54f1-4030-8722-dc2c86f02589"}}}]}, {"uuid": "b434d51d-ba3f-4122-87f2-6ff564f6efdc", "name": "load_p1rlv836_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12556ab7-c50a-4624-9d84-b85585822245"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5f7fb70e-fa24-40c4-b113-ee644f4111bd"}}}}, {"uuid": "15ca6d0b-f87e-47b7-9e40-dab53f7172ed", "name": "745a9d60-cfb1-4af2-b253-0383da07e4e7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4663769608466568, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5502546109327153, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e1a94eab-8ce7-4787-b6c2-86c56ef4334e", "name": "48636bca-59fb-48b8-bdf7-303c97e0d622", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "15ca6d0b-f87e-47b7-9e40-dab53f7172ed"}}}]}, {"uuid": "8c7dd958-fab7-4776-90a0-0cc111dc9d1e", "name": "load_p1rlv837_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33492e0f-c907-46c6-a529-503480b642bb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e1a94eab-8ce7-4787-b6c2-86c56ef4334e"}}}}, {"uuid": "c813fd7f-5cc8-44e7-b411-b841482231f8", "name": "d0cf8302-c91b-43e5-90ed-f81efb1848d5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4663769608466568, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5502546109327153, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d004d951-a13f-4dfc-bbf9-e685e2ba6ccb", "name": "5659efd3-414f-444b-aaa0-0aa0e9454b67", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c813fd7f-5cc8-44e7-b411-b841482231f8"}}}]}, {"uuid": "5744bba1-a670-436a-b29c-c45ce46cfe5c", "name": "load_p1rlv837_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33492e0f-c907-46c6-a529-503480b642bb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d004d951-a13f-4dfc-bbf9-e685e2ba6ccb"}}}}, {"uuid": "e59167f2-ae8c-484a-aed5-6e7518c1e6b6", "name": "f76b109d-e72b-427d-a9aa-b13a297e3018_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3464174292990054, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8802812503815668, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "62c8c8bb-5f9f-42fe-9919-7742b22a5265", "name": "c92d20d8-9859-482f-82c6-033771a0b76b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e59167f2-ae8c-484a-aed5-6e7518c1e6b6"}}}]}, {"uuid": "20ab6f62-5c4e-4508-90ad-6fe1a71ab34a", "name": "load_p1rlv838_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7ffe87d-4424-4495-83c1-6765d385207c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "62c8c8bb-5f9f-42fe-9919-7742b22a5265"}}}}, {"uuid": "c82016b9-e40e-4e2a-b866-4c0541f9db78", "name": "adeda6f9-bfa2-4159-8b66-912227216c35_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3464174292990054, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8802812503815668, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ff51bfab-4d8d-4e23-9397-b7eb2553ca6e", "name": "e31a30f3-80b5-43ae-b498-a38eb7e2f8db", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c82016b9-e40e-4e2a-b866-4c0541f9db78"}}}]}, {"uuid": "a0507800-213a-4e03-b02b-72090c6c2e93", "name": "load_p1rlv838_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7ffe87d-4424-4495-83c1-6765d385207c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ff51bfab-4d8d-4e23-9397-b7eb2553ca6e"}}}}, {"uuid": "8791ab4c-c618-4962-a1ef-ae457fefd9f1", "name": "b7168462-c24d-43bb-b983-55d3b9b9c877_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3086582709384027, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12628327836733033, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0d61d9c4-026e-44a3-9fc9-57e3a534a981", "name": "8b80649c-86e8-4ea2-9fc4-c25a8da3d6ae", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8791ab4c-c618-4962-a1ef-ae457fefd9f1"}}}]}, {"uuid": "5c2fe452-6368-42d8-b1f6-801d4285f1e9", "name": "load_p1rlv839_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48e97be9-1f80-457f-a56e-79f54458c620"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0d61d9c4-026e-44a3-9fc9-57e3a534a981"}}}}, {"uuid": "e9891289-6645-40d0-b3f4-3fe938d4bf4f", "name": "a9c3ba8d-6e50-4b4b-b2ee-49b081413bb5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3086582709384027, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12628327836733033, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "709a13e8-7896-411c-8060-b8656b4b1b2d", "name": "079e76c7-3459-47d4-b774-90bfc1ec9ccd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e9891289-6645-40d0-b3f4-3fe938d4bf4f"}}}]}, {"uuid": "2a329d21-97c6-47ac-a98c-2406bd17b0cc", "name": "load_p1rlv839_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48e97be9-1f80-457f-a56e-79f54458c620"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "709a13e8-7896-411c-8060-b8656b4b1b2d"}}}}, {"uuid": "01bc638c-a479-4e7d-805a-d7137f576946", "name": "eafe6c48-c593-468e-880b-d8c42d7e1e87_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4950137537296666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31506625700854357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "de546a87-f52b-4343-b6d8-ee5fdc026203", "name": "d42df018-de45-407f-9f08-2f702c2f0468", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "01bc638c-a479-4e7d-805a-d7137f576946"}}}]}, {"uuid": "990c975d-7dac-4138-ae0e-698b5d9d1b39", "name": "load_p1rlv840_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "024961c3-25f4-4a15-a52a-7f88dc652766"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "de546a87-f52b-4343-b6d8-ee5fdc026203"}}}}, {"uuid": "ec04d3e5-797c-48a5-8ab7-57dd0a77a3c9", "name": "9f29c20c-d852-4c24-877d-0bbb7058be6c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4950137537296666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31506625700854357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f42e8ec-3919-43ad-9346-b9ee5da3f499", "name": "4332240a-aa4d-464f-88a9-7b0f4ae0b295", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ec04d3e5-797c-48a5-8ab7-57dd0a77a3c9"}}}]}, {"uuid": "ab9f5e05-2970-4924-8a85-aae4fe263b3e", "name": "load_p1rlv840_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "024961c3-25f4-4a15-a52a-7f88dc652766"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f42e8ec-3919-43ad-9346-b9ee5da3f499"}}}}, {"uuid": "9785cfe5-256a-486d-a324-1bd5f30a5e19", "name": "1702e774-78fc-4206-b45b-14bb4f2aa4ba_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9614713621548963, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.170985110067395, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "475962a7-6780-4135-86e3-009d5d683a6b", "name": "7ca65b02-a7da-434d-9c31-f495b72c312c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9785cfe5-256a-486d-a324-1bd5f30a5e19"}}}]}, {"uuid": "cfa6d704-c332-44d1-ba2e-31172bba49da", "name": "load_p1rlv841_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eb6c1b4-f09a-44a5-a13f-64051183736d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "475962a7-6780-4135-86e3-009d5d683a6b"}}}}, {"uuid": "8f3aa178-a4a2-4884-b53f-a8f2409614ba", "name": "16a86396-039a-474c-aa5f-a2e098358315_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.9614713621548963, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.170985110067395, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "04943b34-4a8a-422e-aef7-d4470dc9b981", "name": "2c38238e-59a3-4fd1-93ff-671ebc712e95", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8f3aa178-a4a2-4884-b53f-a8f2409614ba"}}}]}, {"uuid": "e7720fb8-1f33-4c47-be4b-88e5a430b611", "name": "load_p1rlv841_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eb6c1b4-f09a-44a5-a13f-64051183736d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "04943b34-4a8a-422e-aef7-d4470dc9b981"}}}}, {"uuid": "b7af79f8-1862-46b0-b51f-0c825baf15d9", "name": "64556f90-f1e4-4e44-a053-a9d536fb1e79_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8285317723273034, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9836303634928509, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "48ca5f56-bf1f-45f8-b8bb-9b040ded4573", "name": "0b6cf306-da1f-4286-a5a2-521ba012fd54", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b7af79f8-1862-46b0-b51f-0c825baf15d9"}}}]}, {"uuid": "0940874a-e752-42c9-90ae-e7be990bb853", "name": "load_p1rlv842_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8f304a4-6e39-4288-9b9b-e41bb37c6019"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "48ca5f56-bf1f-45f8-b8bb-9b040ded4573"}}}}, {"uuid": "627dcd89-b96d-4c13-8abd-b98c9111fd73", "name": "df20d7e6-68c2-4695-b4f1-fa4ca288c8dc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8285317723273034, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9836303634928509, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8ba1a638-dfb0-4e1d-b530-78df11b9d5f1", "name": "cb3c7422-da41-45c7-9a9d-993d5a4a6897", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "627dcd89-b96d-4c13-8abd-b98c9111fd73"}}}]}, {"uuid": "cb3eaf0a-c353-43bc-94b1-764ed209ad42", "name": "load_p1rlv842_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8f304a4-6e39-4288-9b9b-e41bb37c6019"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8ba1a638-dfb0-4e1d-b530-78df11b9d5f1"}}}}, {"uuid": "9829bdca-2176-4d31-8c70-d08643ab2027", "name": "59648600-ec8c-4903-afae-2622087f494a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7943609059660943, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8824322096654456, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b701fec3-1eb1-4beb-b725-fb95c0b2c7c7", "name": "86103c0d-dcad-49b9-aa08-f4b555bae597", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9829bdca-2176-4d31-8c70-d08643ab2027"}}}]}, {"uuid": "13454edd-3943-4d68-9ce7-b08db819335a", "name": "load_p1rlv843_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3bc013f-c78d-4a3c-b27f-826c3025de0e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b701fec3-1eb1-4beb-b725-fb95c0b2c7c7"}}}}, {"uuid": "36e9cb2d-c336-43c7-958f-597584a7b4d6", "name": "ce8e56f3-a73d-41f0-97db-1f768e25f537_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7943609059660943, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8824322096654456, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c4a7ab30-c1ad-4ce7-97b2-2604f23ea4f3", "name": "6a5bd58b-6aba-407c-9d12-4cc182b603fb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "36e9cb2d-c336-43c7-958f-597584a7b4d6"}}}]}, {"uuid": "eb0a4e99-8354-47ec-a036-a49ce41f9bcc", "name": "load_p1rlv843_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3bc013f-c78d-4a3c-b27f-826c3025de0e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c4a7ab30-c1ad-4ce7-97b2-2604f23ea4f3"}}}}, {"uuid": "ffa75d2e-5c98-4afa-b23b-f70dd0be73a3", "name": "ed64f055-1c53-4159-a244-06b2e908e817_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.062987656442733, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.2699236524876967, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ca2f73cf-b69b-4011-ab51-ca490b35fd76", "name": "3facab19-f51f-47e3-b137-1a3803f920ee", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ffa75d2e-5c98-4afa-b23b-f70dd0be73a3"}}}]}, {"uuid": "946b5b25-8afa-4bde-9b2a-c736d884eec9", "name": "load_p1rlv844_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26294827-db76-40b6-b652-1e41efdf15dc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ca2f73cf-b69b-4011-ab51-ca490b35fd76"}}}}, {"uuid": "c6f6f984-64c4-4396-89fd-c9c47042fc28", "name": "b62398c0-d470-441b-a912-a47fced3a655_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.062987656442733, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.2699236524876967, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "28fc005b-75dd-46c7-b9db-d5e8c6127aa1", "name": "772310ab-cafb-49ea-8f32-60a74196f0f6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c6f6f984-64c4-4396-89fd-c9c47042fc28"}}}]}, {"uuid": "a7e0dcd0-a7c6-4adb-b88f-f492af62b272", "name": "load_p1rlv844_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26294827-db76-40b6-b652-1e41efdf15dc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "28fc005b-75dd-46c7-b9db-d5e8c6127aa1"}}}}, {"uuid": "b4003b35-2b3b-4af0-8de4-604977581c97", "name": "8cb5ff7f-5aef-42bf-9119-a05dad52b9f9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.910200682298975, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5555412020426419, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ab226e6d-82fd-41e8-b993-5b84b51eb4ff", "name": "39b0862f-feb7-4da5-885d-73d78e073189", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b4003b35-2b3b-4af0-8de4-604977581c97"}}}]}, {"uuid": "8376fc1a-b59f-43cb-a5a8-44d0b44d29ab", "name": "load_p1rlv845_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b053d449-b15b-4292-9a73-9b7d104a8e38"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ab226e6d-82fd-41e8-b993-5b84b51eb4ff"}}}}, {"uuid": "c3958938-cbd3-472a-9c99-95806bb84b3f", "name": "f59a083b-e6d9-4685-aeb1-0cf60622c86e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.910200682298975, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5555412020426419, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "00461c76-6c87-4612-bc51-1d0989527a7b", "name": "0c09ca8e-8769-4600-a588-90eca8873146", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c3958938-cbd3-472a-9c99-95806bb84b3f"}}}]}, {"uuid": "d0b71404-56b4-4fe4-ab8d-b5cf552f66b9", "name": "load_p1rlv845_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b053d449-b15b-4292-9a73-9b7d104a8e38"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "00461c76-6c87-4612-bc51-1d0989527a7b"}}}}, {"uuid": "a55e9cf6-429f-4c71-87de-16ec31853880", "name": "a262e4df-1fef-433b-9ab9-abd8ae469f43_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.772705532239135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.33568286747913667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fa5a99e8-9d11-4954-acc6-47fc1451bbac", "name": "4fcfc64d-9655-48a4-9536-f39ed0b9f374", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a55e9cf6-429f-4c71-87de-16ec31853880"}}}]}, {"uuid": "638ffa96-1e7e-4d99-8bee-907f52cbcc88", "name": "load_p1rlv846_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "145d3757-ca09-45ca-9199-465b6b43fbb7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fa5a99e8-9d11-4954-acc6-47fc1451bbac"}}}}, {"uuid": "2929e2ac-0e30-46eb-b71b-5364e978fe8d", "name": "8365ebed-ff8a-4203-a100-4913109d1bdd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.772705532239135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.33568286747913667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fb5a7159-cbc6-49b0-b1cb-ebcc1dec4b1a", "name": "f5d2c0ae-6b91-4a0b-8817-e22c4ba36710", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2929e2ac-0e30-46eb-b71b-5364e978fe8d"}}}]}, {"uuid": "fec9c5f7-9aa9-48ac-92b1-e3d93fee3c65", "name": "load_p1rlv846_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "145d3757-ca09-45ca-9199-465b6b43fbb7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fb5a7159-cbc6-49b0-b1cb-ebcc1dec4b1a"}}}}, {"uuid": "fa3f6062-4671-4203-8049-c4fad65a9237", "name": "5ecc8f7c-532c-4803-93d5-a8b2ff8bf3aa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2075389461119934, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3167249782629938, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "33d3cde7-a420-435c-8b91-31dfe50c2860", "name": "50247295-4690-4540-bb6a-ccbbdb6d5bf7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fa3f6062-4671-4203-8049-c4fad65a9237"}}}]}, {"uuid": "9c473154-b8b2-4064-9a6a-89dc5a54b69f", "name": "load_p1rlv847_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "283142ff-4884-4adc-9d4c-f8615505415a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "33d3cde7-a420-435c-8b91-31dfe50c2860"}}}}, {"uuid": "c9fc333b-5a54-4b28-a6d4-cd6ccdfe2b6b", "name": "53b25bbb-72d0-4a3d-86a3-0fa55219cfd3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2075389461119934, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3167249782629938, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "969e7e4a-dd5b-46ae-b883-2eb2b40f848b", "name": "e35fb445-415a-4951-853a-47d951f12a41", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9fc333b-5a54-4b28-a6d4-cd6ccdfe2b6b"}}}]}, {"uuid": "14a2504d-01b8-4aac-8748-b0376320ab33", "name": "load_p1rlv847_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "283142ff-4884-4adc-9d4c-f8615505415a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "969e7e4a-dd5b-46ae-b883-2eb2b40f848b"}}}}, {"uuid": "c09d2a7a-d38b-4a5f-86b4-9aea3f3f91b7", "name": "cb6907ad-7410-4473-b3f4-3da1ba202a27_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4794755457968312, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.46197673612457824, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6d3e07b4-1a35-48c9-8adc-6f52113102d6", "name": "e8755510-0e03-4a73-9cce-6b4a79f27838", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c09d2a7a-d38b-4a5f-86b4-9aea3f3f91b7"}}}]}, {"uuid": "4ebbbbb3-7e08-4715-aceb-51a122998f2f", "name": "load_p1rlv848_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e484d77-29ac-4903-afa3-f677283db883"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6d3e07b4-1a35-48c9-8adc-6f52113102d6"}}}}, {"uuid": "51a4e04c-711d-4bd6-8316-c648e2b89856", "name": "6235b454-706d-49e7-ac71-a9344113b912_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4794755457968312, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.46197673612457824, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fd740f4a-7f4c-4795-9bd3-939ec892f916", "name": "d30fa4e9-56e8-4d00-8ca9-0f242173d56f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "51a4e04c-711d-4bd6-8316-c648e2b89856"}}}]}, {"uuid": "5a98bb20-7c07-4b1b-bd7b-d5c289466cf2", "name": "load_p1rlv848_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e484d77-29ac-4903-afa3-f677283db883"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fd740f4a-7f4c-4795-9bd3-939ec892f916"}}}}, {"uuid": "8cab14d9-0a0f-40bf-9b68-d1e2e46939f8", "name": "fd72b7b0-105f-4add-bbd1-d9df40e05337_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.292799122473319, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5385753507809203, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cf07e1f2-31e7-488d-bdb8-479391d57add", "name": "c9581250-75c5-46bd-bb58-d7a7bbd303f7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8cab14d9-0a0f-40bf-9b68-d1e2e46939f8"}}}]}, {"uuid": "4472bb76-70f3-44ff-9d15-46518c7d0d04", "name": "load_p1rlv849_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a95877ca-8600-4e95-82ac-c51cb82acf16"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cf07e1f2-31e7-488d-bdb8-479391d57add"}}}}, {"uuid": "da281240-6876-4756-b99e-99707b3e4b53", "name": "b446a498-18f1-40f2-b50d-fe77f39b60b8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.292799122473319, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5385753507809203, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7e6c224f-9f73-450b-9560-75283650ef2c", "name": "98426f92-904d-4b94-b1e0-99d6c346f267", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "da281240-6876-4756-b99e-99707b3e4b53"}}}]}, {"uuid": "a388bf38-0fb8-4c4b-8736-53457df89b59", "name": "load_p1rlv849_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a95877ca-8600-4e95-82ac-c51cb82acf16"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7e6c224f-9f73-450b-9560-75283650ef2c"}}}}, {"uuid": "079e87a7-2dcf-4c41-82c1-d355db6fd5b7", "name": "da6e5544-3742-4ded-9307-e762416cee5e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.737986692242784, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8906640815201406, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b71072af-4d15-4d1d-bfc9-3edcda196026", "name": "e94dd721-a476-469d-a978-b2f77a3e172c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "079e87a7-2dcf-4c41-82c1-d355db6fd5b7"}}}]}, {"uuid": "b4ac23ec-155a-40fd-85f4-77c43c345631", "name": "load_p1rlv850_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d49057-9c70-4489-95bb-36b5b574e13d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b71072af-4d15-4d1d-bfc9-3edcda196026"}}}}, {"uuid": "c95ac71a-681f-4509-9eba-895a289012d8", "name": "e333efe5-158e-43aa-bdac-155844fbd620_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.737986692242784, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8906640815201406, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "87ddf4da-1542-4022-ad08-cf51913dcf99", "name": "178dc8e1-2375-4a0d-b439-b31c05197025", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c95ac71a-681f-4509-9eba-895a289012d8"}}}]}, {"uuid": "ae73fe56-081e-4996-9bff-d4b073c8dd98", "name": "load_p1rlv850_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d49057-9c70-4489-95bb-36b5b574e13d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "87ddf4da-1542-4022-ad08-cf51913dcf99"}}}}, {"uuid": "938176d6-c264-46f9-b916-44fa987b069a", "name": "2d46fa4e-175e-4ec6-b74d-5dfa3815b18e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6295328634326751, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9988748196040309, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f74787d6-5835-45fa-9290-422bed794f4d", "name": "fa19786d-68d6-4c6a-a062-9235f7c8dfee", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "938176d6-c264-46f9-b916-44fa987b069a"}}}]}, {"uuid": "8a15f266-4f98-4288-8ba5-263a877aeb48", "name": "load_p1rlv851_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48b5535c-f00d-4b48-a23a-87f3f212302f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f74787d6-5835-45fa-9290-422bed794f4d"}}}}, {"uuid": "6b120a3a-f663-4d9f-a57c-ddfd8f2dec4b", "name": "ca2a0e01-00ff-4ef4-aaa5-8aae694aea9f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6295328634326751, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9988748196040309, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fb9087aa-1791-47a4-adeb-a6547ac17b6c", "name": "31097e7a-9eec-4dfa-9a62-3b613bf8bf26", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6b120a3a-f663-4d9f-a57c-ddfd8f2dec4b"}}}]}, {"uuid": "ac397b0f-76ec-4e36-b6c8-415905f2bb6f", "name": "load_p1rlv851_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48b5535c-f00d-4b48-a23a-87f3f212302f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fb9087aa-1791-47a4-adeb-a6547ac17b6c"}}}}, {"uuid": "c2a1f7b5-19ab-47aa-937f-05f52627dddc", "name": "659a36bd-a7aa-4dec-9acf-d31fbb16260a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.072248840478098, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4856137999354615, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f9ad31eb-3ffb-4797-a746-b1604ab4f2b7", "name": "2bdc508a-656f-4100-861f-98a999f72776", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c2a1f7b5-19ab-47aa-937f-05f52627dddc"}}}]}, {"uuid": "32ef83b5-8cc7-4a68-93b8-41764a6abcaa", "name": "load_p1rlv852_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32142941-c546-4356-ba80-123b9128b5de"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f9ad31eb-3ffb-4797-a746-b1604ab4f2b7"}}}}, {"uuid": "86075a23-c51e-49ba-af91-77ff46df6dd3", "name": "01103004-1ff0-4f2c-99f8-3cc408fc55a0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.072248840478098, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4856137999354615, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c6d823a9-35a7-45f1-b243-e78bf6fe23b5", "name": "36396a64-3c5d-4b86-945a-0b3d3cd6d5db", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "86075a23-c51e-49ba-af91-77ff46df6dd3"}}}]}, {"uuid": "ae20b46b-5e41-4a03-9a59-55b7522c841d", "name": "load_p1rlv852_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32142941-c546-4356-ba80-123b9128b5de"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c6d823a9-35a7-45f1-b243-e78bf6fe23b5"}}}}, {"uuid": "96605a2b-6efd-43aa-8a81-f5fc0dba3f0e", "name": "deaf567c-a026-4554-a0a7-687792ab63e9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0307394237991176, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0095205649117913, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "123eebfc-2042-4715-ab91-25732d479e72", "name": "c4872abd-c3bc-4209-8802-bc99fe0f02c3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "96605a2b-6efd-43aa-8a81-f5fc0dba3f0e"}}}]}, {"uuid": "0f13dd75-128f-4674-8647-5b56add5b599", "name": "load_p1rlv853_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "365eff25-8ccb-448b-894f-ad662fe6d684"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "123eebfc-2042-4715-ab91-25732d479e72"}}}}, {"uuid": "8facf6cb-c11b-4172-92b8-83e781a3b8f1", "name": "7cd73183-8983-48c8-b26e-296f3dbe8117_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0307394237991176, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0095205649117913, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "95f41b66-dea3-421b-8f9a-154274c833cf", "name": "9e2d777a-b466-42de-837a-34372aee43f6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8facf6cb-c11b-4172-92b8-83e781a3b8f1"}}}]}, {"uuid": "758828f8-84b9-4627-aa37-55b2e0484323", "name": "load_p1rlv853_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "365eff25-8ccb-448b-894f-ad662fe6d684"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "95f41b66-dea3-421b-8f9a-154274c833cf"}}}}, {"uuid": "717840ac-6dd6-4827-bd43-a554fb72da8c", "name": "d0ee04c6-6faf-4755-9ffa-0969c8e06caf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.621947646480353, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0332384495271123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "64472809-31e9-4821-a8a2-607cb1c44575", "name": "aaa6b3c4-c3d3-457f-b6a7-c3ab9f5eb44e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "717840ac-6dd6-4827-bd43-a554fb72da8c"}}}]}, {"uuid": "9bb9e900-0cbe-480f-b913-d84926db0a02", "name": "load_p1rlv854_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2461b6f0-9a40-4b6f-9669-be479da039f3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "64472809-31e9-4821-a8a2-607cb1c44575"}}}}, {"uuid": "16562700-f4db-4517-abbb-5aa91fff7652", "name": "d3a5a834-ea15-484f-9dde-fcdb1d49033b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.621947646480353, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0332384495271123, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cfd37b6d-06db-482a-afb3-8fa4f7a686b5", "name": "411c31b0-e7a3-40e7-adda-02517fe0908e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "16562700-f4db-4517-abbb-5aa91fff7652"}}}]}, {"uuid": "b83a0389-140e-4844-80a2-41f2bffe2b90", "name": "load_p1rlv854_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2461b6f0-9a40-4b6f-9669-be479da039f3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cfd37b6d-06db-482a-afb3-8fa4f7a686b5"}}}}, {"uuid": "f600b2dc-6cdb-4b19-97ad-d56551e79ab4", "name": "e150596e-4503-4ecf-9026-bf049ae0d6fc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.037961707989467, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3691190849967326, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "224dd4bd-f3ff-4f50-97d3-2fdc005e0de3", "name": "ed0f82f0-768d-456c-b6e9-0ee41ce84c6a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f600b2dc-6cdb-4b19-97ad-d56551e79ab4"}}}]}, {"uuid": "7a5ba2e4-3885-4be5-b672-99b3fae2d8c3", "name": "load_p1rlv855_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10611e08-75e2-4422-ac0f-cfb98c7eae4b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "224dd4bd-f3ff-4f50-97d3-2fdc005e0de3"}}}}, {"uuid": "6e323aa2-ba11-48d0-81ef-41387111c606", "name": "eac6cc37-cbe4-4fb4-8a1d-bc90e9fa3754_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.037961707989467, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3691190849967326, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5c3af5ce-5414-41ea-9c5c-89efe6d0d90a", "name": "93900ca9-c875-4baf-81a9-4f3c3d29dace", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6e323aa2-ba11-48d0-81ef-41387111c606"}}}]}, {"uuid": "ceb6e0a6-d1af-4b49-83a3-ec99e79b538f", "name": "load_p1rlv855_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10611e08-75e2-4422-ac0f-cfb98c7eae4b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5c3af5ce-5414-41ea-9c5c-89efe6d0d90a"}}}}, {"uuid": "6df6841e-86ca-4dec-8dcd-4d1e7737d659", "name": "98ba7850-57fc-45a0-b3e0-7d705b57c157_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0599252267318962, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3748861224482183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "84f46b25-5bba-449b-bb71-0fd1708d7b9c", "name": "e9e7e068-991b-428e-bba2-5378e50498cc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6df6841e-86ca-4dec-8dcd-4d1e7737d659"}}}]}, {"uuid": "621bdbbe-256c-4cc9-be75-89226e86b452", "name": "load_p1rlv856_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25f84b28-695b-4d32-b96c-914226444b9f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "84f46b25-5bba-449b-bb71-0fd1708d7b9c"}}}}, {"uuid": "04f372ca-5429-44cc-8e92-039e9872f677", "name": "c7fc900a-9761-4cd4-8341-b345266840fb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0599252267318962, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3748861224482183, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1166a1ab-a5b1-456c-8bd7-a71a202292ff", "name": "d9b7e884-83d2-470d-bda2-9909f008c41d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "04f372ca-5429-44cc-8e92-039e9872f677"}}}]}, {"uuid": "ae996b2d-1dea-4f61-99a5-a53fcb898980", "name": "load_p1rlv856_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25f84b28-695b-4d32-b96c-914226444b9f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1166a1ab-a5b1-456c-8bd7-a71a202292ff"}}}}, {"uuid": "9b8f6789-1de8-413d-a3c4-5410bef958a2", "name": "88d15826-274e-4901-8860-5e4d7a9c38d6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7943609059660943, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8824322096654456, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2eeb66ef-6a15-4ad6-add3-1a48e608df1b", "name": "c859bfb6-b1e9-467f-a6ba-c0a872cd4dac", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9b8f6789-1de8-413d-a3c4-5410bef958a2"}}}]}, {"uuid": "2afb5f2d-a7d6-4d0d-814f-9ed02e37d632", "name": "load_p1rlv857_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a28cc17a-125d-4b7b-a697-230e3f8853b5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2eeb66ef-6a15-4ad6-add3-1a48e608df1b"}}}}, {"uuid": "9aa8e408-47da-4da3-b3eb-a373bf49b2b0", "name": "b4a34dc0-77f6-48fd-974b-3e39b8b29a49_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.7943609059660943, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8824322096654456, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "234024af-de66-4b33-8129-d6b8059bdd80", "name": "75c1079f-de07-4098-bd81-29f4198fc437", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9aa8e408-47da-4da3-b3eb-a373bf49b2b0"}}}]}, {"uuid": "094df460-37a3-4b56-a3b9-f5b2b6be0ba3", "name": "load_p1rlv857_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a28cc17a-125d-4b7b-a697-230e3f8853b5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "234024af-de66-4b33-8129-d6b8059bdd80"}}}}, {"uuid": "7323b44d-a2c5-4f50-b500-5800eb2f378e", "name": "a23685aa-5fd7-4cf5-a7a7-40e6e2203420_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.360087651208046, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7361845082285076, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a1c70345-7ac7-4ce2-a973-c7c9094de834", "name": "9a73ab21-8bd4-42fc-8948-6e32c8dee34d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7323b44d-a2c5-4f50-b500-5800eb2f378e"}}}]}, {"uuid": "2d3bce52-a0d9-407c-9a3d-47bad3f824a1", "name": "load_p1rlv858_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab33ce2f-3131-4cfb-8df2-329fb4aa76b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a1c70345-7ac7-4ce2-a973-c7c9094de834"}}}}, {"uuid": "a75b42ea-cf4f-482a-818d-e620e774eaba", "name": "6cd91bc1-b5b9-4e8d-9a2a-e6ae360b7edb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.360087651208046, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7361845082285076, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a51406a8-a8d8-4294-a054-2829c350a2c5", "name": "0b07e4b1-3489-4d32-9b21-cdb8c09841d9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a75b42ea-cf4f-482a-818d-e620e774eaba"}}}]}, {"uuid": "bd4c08fd-1f86-4ca0-861b-d97428390c2a", "name": "load_p1rlv858_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab33ce2f-3131-4cfb-8df2-329fb4aa76b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a51406a8-a8d8-4294-a054-2829c350a2c5"}}}}, {"uuid": "35086a57-9857-4866-a09e-231dd9f6fca0", "name": "e8a02a80-3e02-43f8-86aa-0139292ee6c8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.292799122473319, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5385753507809203, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "092c0dd2-64c4-4fdb-b042-0fba4bd9bd72", "name": "b309218d-ff40-4e21-b696-16d8cb4504e8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "35086a57-9857-4866-a09e-231dd9f6fca0"}}}]}, {"uuid": "ea82bf4d-44fc-471f-bb20-faa13e025ddc", "name": "load_p1rlv859_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ea0f4f5-2024-45a8-9f8f-f5963e7d2727"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "092c0dd2-64c4-4fdb-b042-0fba4bd9bd72"}}}}, {"uuid": "15eca634-df48-414d-a350-28d6a67c60ac", "name": "10d83fbf-95e7-4c47-84ea-795b3e674406_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.292799122473319, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5385753507809203, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4f3dd59b-9b2a-4fa7-b2f0-77b46d74ea85", "name": "5909bc2c-6ea9-400d-a1ac-7ec4cf3b3195", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "15eca634-df48-414d-a350-28d6a67c60ac"}}}]}, {"uuid": "1d319791-32ab-4a13-9b3a-4c28dfee0e16", "name": "load_p1rlv859_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ea0f4f5-2024-45a8-9f8f-f5963e7d2727"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4f3dd59b-9b2a-4fa7-b2f0-77b46d74ea85"}}}}, {"uuid": "3946463d-5ba0-4265-99c7-f95fda7d6324", "name": "c226f9fe-97d4-4f13-a604-ed5ef5335011_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5424601784243566, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31457775613808403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9b716c1f-225f-4a38-b498-7f218bc827ff", "name": "ec4ad5d1-316c-48cc-adf4-d43151ae92d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3946463d-5ba0-4265-99c7-f95fda7d6324"}}}]}, {"uuid": "5ea998e1-259b-4b48-86ae-f263a6e51b5c", "name": "load_p1rlv860_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bada1117-5605-4aec-9314-8013ed243e3c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9b716c1f-225f-4a38-b498-7f218bc827ff"}}}}, {"uuid": "39e0e2ea-3427-41a3-a24c-f874143fd4cf", "name": "c975a955-75c7-4e7c-b1bf-c42d83f0ee8d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5424601784243566, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31457775613808403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ab3bcd05-6f6f-4d10-8807-13db4da37a09", "name": "90e3bd87-98c5-4cff-b849-90a6c5e49d55", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "39e0e2ea-3427-41a3-a24c-f874143fd4cf"}}}]}, {"uuid": "087c8d07-6c8a-4ea0-8c2e-36d042741e85", "name": "load_p1rlv860_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bada1117-5605-4aec-9314-8013ed243e3c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ab3bcd05-6f6f-4d10-8807-13db4da37a09"}}}}, {"uuid": "b615cda8-1baf-4369-99b6-e1aa112b1d04", "name": "b0859b4f-82e2-43c9-a5e7-4d90cbf261fc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2766983969851713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5028612878254624, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2b07c294-9599-4629-ab6a-de6a01d14c82", "name": "e7546a56-0a12-4d9c-8664-ed7e6eb841c1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b615cda8-1baf-4369-99b6-e1aa112b1d04"}}}]}, {"uuid": "96800c02-0db3-4db9-b8b6-28b7fc263295", "name": "load_p1rlv861_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a07d30f-6909-4d74-be8a-1ff8343b4419"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2b07c294-9599-4629-ab6a-de6a01d14c82"}}}}, {"uuid": "4659d82a-2d77-4710-82ac-960b753b0425", "name": "3bbc9222-9155-4c7a-9d39-cb8512724ca8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2766983969851713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5028612878254624, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "72a5a44c-ba79-466f-abea-f385d63ff89d", "name": "e23362be-3012-4f38-9444-437cf2f9fb67", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4659d82a-2d77-4710-82ac-960b753b0425"}}}]}, {"uuid": "1cf2e81e-bfb4-48c2-9ef3-c4244e1d4176", "name": "load_p1rlv861_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a07d30f-6909-4d74-be8a-1ff8343b4419"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "72a5a44c-ba79-466f-abea-f385d63ff89d"}}}}, {"uuid": "36119b84-0eeb-4a54-a521-ea143e122c70", "name": "f8af5d24-b499-47a4-bf61-a9a39a38a305_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.037961707989467, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3691190849967326, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "aaa7a400-9669-453e-987b-e49830388166", "name": "b597c1da-1f78-4424-92de-98ee97ef58bd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "36119b84-0eeb-4a54-a521-ea143e122c70"}}}]}, {"uuid": "49da019f-d34e-4676-a7c3-83d7fdd9f1d1", "name": "load_p1rlv862_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5e2c3a2-32c0-4bb9-9802-265cec784974"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "aaa7a400-9669-453e-987b-e49830388166"}}}}, {"uuid": "5006d372-3b1d-408c-abe2-6f3208eac730", "name": "ba8b441d-bec1-43f1-8574-b8a92ff222ba_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.037961707989467, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3691190849967326, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f31efed1-ba00-4062-ab30-6e483d25fc84", "name": "210c84bb-bc4c-4f53-ad8c-625114ae5c83", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5006d372-3b1d-408c-abe2-6f3208eac730"}}}]}, {"uuid": "fd3a664f-196a-43fa-bfdc-53efd02af17c", "name": "load_p1rlv862_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5e2c3a2-32c0-4bb9-9802-265cec784974"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f31efed1-ba00-4062-ab30-6e483d25fc84"}}}}, {"uuid": "ace38ad0-adb5-413b-b79d-668ae95cb220", "name": "ceae3b7d-532d-4b92-a59b-64dee73af957_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1350143243427975, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1351898450115188, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d7fbc366-1f07-41d0-bec5-af65c6df29d4", "name": "15d9ac3c-7a40-46a9-9835-115380acddf0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ace38ad0-adb5-413b-b79d-668ae95cb220"}}}]}, {"uuid": "5966ebaa-cfd3-4095-ade4-1f653ab63ea7", "name": "load_p1rlv863_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09a7be46-a1bf-459d-836b-beb64324809b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d7fbc366-1f07-41d0-bec5-af65c6df29d4"}}}}, {"uuid": "1d53c84b-81f1-420c-8482-438a751eed35", "name": "3da80d10-b10f-4974-a8f9-5dd2816e5bd9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1350143243427975, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1351898450115188, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "37c8776e-dbfe-404b-b52e-a7685eca1be1", "name": "e545727b-1cfe-4117-be2f-530ecedfdadf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1d53c84b-81f1-420c-8482-438a751eed35"}}}]}, {"uuid": "7033a7f2-be4e-454a-a54a-997dfcea2f79", "name": "load_p1rlv863_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09a7be46-a1bf-459d-836b-beb64324809b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "37c8776e-dbfe-404b-b52e-a7685eca1be1"}}}}, {"uuid": "679bc03a-95ec-4dac-b478-740fb11b7f8b", "name": "026f57e0-a554-4cd6-aff1-1162bc769970_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0404861968223509, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5307917165881004, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0b92cee6-e830-479d-98b9-5b58f61604e9", "name": "d677f903-718f-4ebe-acc8-9aa5591d70a4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "679bc03a-95ec-4dac-b478-740fb11b7f8b"}}}]}, {"uuid": "7fb1a340-9cdd-4d27-87c6-975d10aab344", "name": "load_p1rlv864_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e2a8871-7bc4-497f-9954-38db92cb3eba"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0b92cee6-e830-479d-98b9-5b58f61604e9"}}}}, {"uuid": "51792ec8-29d7-4f26-8ccf-07b1c59ea1fe", "name": "441a7382-13b0-4a4b-a9cb-a6efc1080bce_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.0404861968223509, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5307917165881004, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50e57df0-1fc7-4e3b-a217-56d086a3f85d", "name": "f845ac47-866f-4ed9-bd8d-b7b2968e8703", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "51792ec8-29d7-4f26-8ccf-07b1c59ea1fe"}}}]}, {"uuid": "5f436709-285d-4efc-b7a5-b90e8d251195", "name": "load_p1rlv864_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e2a8871-7bc4-497f-9954-38db92cb3eba"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50e57df0-1fc7-4e3b-a217-56d086a3f85d"}}}}, {"uuid": "38cc0407-c5ca-4e8b-89f6-76d0f546dc24", "name": "222da507-c072-4b19-a029-97d7de16ca33_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.396349422902612, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13402564403017767, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a83ec3a0-5d64-4bfe-ae1a-d5fb9a412442", "name": "d6ed423b-17ab-463e-9c6f-6c4ea05e864c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "38cc0407-c5ca-4e8b-89f6-76d0f546dc24"}}}]}, {"uuid": "c2714419-2921-4ab1-b9c6-5aa354bac9c6", "name": "load_p1rlv865_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abdfa5db-c398-4638-805d-6d55597e1921"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a83ec3a0-5d64-4bfe-ae1a-d5fb9a412442"}}}}, {"uuid": "8144f7d5-cfad-47c7-bc29-c99638c052ee", "name": "5a0fbef2-a383-4d19-b9b5-a19466da2dcf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.396349422902612, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13402564403017767, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6527d9ad-e156-4133-acb9-f3e5763eec6c", "name": "d1944846-4e8d-4ef5-8a4c-1555100cb335", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8144f7d5-cfad-47c7-bc29-c99638c052ee"}}}]}, {"uuid": "13136e7a-d669-4975-b669-a1c432915c92", "name": "load_p1rlv865_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abdfa5db-c398-4638-805d-6d55597e1921"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6527d9ad-e156-4133-acb9-f3e5763eec6c"}}}}, {"uuid": "42bfd63a-37b3-4f04-8158-3ef4471651bf", "name": "3f3992b8-a126-4bb3-b05c-89840855c1f0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3885774782241163, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12624891415512582, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "560745e8-0452-43ef-81d7-630181294706", "name": "cce335ea-f452-48ad-8707-9c2d3280e24c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "42bfd63a-37b3-4f04-8158-3ef4471651bf"}}}]}, {"uuid": "b2b6fa33-8085-4b64-82cd-4fe96219ea44", "name": "load_p1rlv866_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b4834dc-6bdf-4102-bc13-589392b2e75a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "560745e8-0452-43ef-81d7-630181294706"}}}}, {"uuid": "968e05c7-a79f-4514-a3de-87e33419cff2", "name": "85ae0cf9-82bc-4d01-b049-fcd4b6fb9ac1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3885774782241163, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.12624891415512582, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d1de2c42-fc5f-4cb4-92ec-5e9beac9c261", "name": "c12a43c2-a29e-4bcd-bdeb-7a0306225d8c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "968e05c7-a79f-4514-a3de-87e33419cff2"}}}]}, {"uuid": "faa57801-b454-43b6-bdda-eeaafa76b9e8", "name": "load_p1rlv866_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b4834dc-6bdf-4102-bc13-589392b2e75a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d1de2c42-fc5f-4cb4-92ec-5e9beac9c261"}}}}, {"uuid": "1c879820-7c35-46b9-8168-00f7e509aef4", "name": "403f8627-c8d6-40e8-bfcb-47c03dcf74d8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6434260893942235, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2588956175598443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "171928bd-80b9-42bb-a91e-b9ab7ae8989a", "name": "f8b5b9e7-4f04-4cdd-bb13-380da2aeb0ea", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1c879820-7c35-46b9-8168-00f7e509aef4"}}}]}, {"uuid": "c6967476-77ef-442f-bfdb-222f6502e733", "name": "load_p1rlv867_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a7cca48-fd4b-4630-a479-55f2b6ada03b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "171928bd-80b9-42bb-a91e-b9ab7ae8989a"}}}}, {"uuid": "114181e2-86b0-4925-9cc9-0d7ca64c7407", "name": "1c2a3eea-1172-431e-87b2-17ad9df21235_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6434260893942235, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2588956175598443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "28a7f3f9-cd2e-428a-a9bd-d33a2e4fed11", "name": "0de580cd-f883-4a16-8008-61a93c33a7da", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "114181e2-86b0-4925-9cc9-0d7ca64c7407"}}}]}, {"uuid": "385a2115-4295-4941-a7fb-a59564b4f508", "name": "load_p1rlv867_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a7cca48-fd4b-4630-a479-55f2b6ada03b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "28a7f3f9-cd2e-428a-a9bd-d33a2e4fed11"}}}}, {"uuid": "b9f7f963-fb43-4e1e-871d-38f0d87206ca", "name": "a1d0da70-7bc9-493c-94ef-abe966f8bcdb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b25e2402-e84a-4a40-80a0-ce8be1a5322b", "name": "2e2a91d1-2bc1-4316-a111-5371893ddf75", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b9f7f963-fb43-4e1e-871d-38f0d87206ca"}}}]}, {"uuid": "2e469aa9-dbf8-4b95-8f28-e8a2fb8c1ea1", "name": "load_p1rlv868_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "009758e3-b4ae-427a-9c30-f2a8bb2953d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b25e2402-e84a-4a40-80a0-ce8be1a5322b"}}}}, {"uuid": "8328adfe-9dc1-4885-b0eb-17be3134c569", "name": "18746686-2a2d-4f4e-bad6-fd16dbe2a33f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "467c6f11-7830-4b68-b6d9-a210abde83f1", "name": "18413f31-a538-4d0d-bd03-11a127f553d3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8328adfe-9dc1-4885-b0eb-17be3134c569"}}}]}, {"uuid": "547a971b-dbf5-4c1f-91ab-7385e3c89f7a", "name": "load_p1rlv868_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "009758e3-b4ae-427a-9c30-f2a8bb2953d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "467c6f11-7830-4b68-b6d9-a210abde83f1"}}}}, {"uuid": "eb92c93e-422c-40d0-b704-4fc3df412ad6", "name": "ffe3ad19-366b-4fd2-9f71-a5b150b6eb7c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.338024948143216, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9096814401074484, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d3416bc5-2dff-48ff-a630-f670458c570d", "name": "d0e0e291-1ed0-4993-8ee3-a05937ce6327", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eb92c93e-422c-40d0-b704-4fc3df412ad6"}}}]}, {"uuid": "4d86c288-ca8d-41fb-8c4d-b10435f7da15", "name": "load_p1rlv869_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fb4003d-498a-494d-89ca-f222d921f63a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d3416bc5-2dff-48ff-a630-f670458c570d"}}}}, {"uuid": "3201dcf9-4b41-468e-a205-000c11004b4e", "name": "6dcbacc4-865b-4a74-be53-090263776564_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.338024948143216, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9096814401074484, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b7edcd35-a7b1-48bc-af27-1b3853eb3475", "name": "6f04df3d-66d0-447a-92b9-abd6bf18984b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3201dcf9-4b41-468e-a205-000c11004b4e"}}}]}, {"uuid": "61512b03-7ff1-4d52-8b9f-426e1d071061", "name": "load_p1rlv869_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fb4003d-498a-494d-89ca-f222d921f63a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b7edcd35-a7b1-48bc-af27-1b3853eb3475"}}}}, {"uuid": "c5372011-7783-401d-9a42-ba2d894a238e", "name": "f1f19423-67b8-402b-8984-0f898b9811cf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4212042062341066, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7562106926743815, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7dbdc0a2-3f64-4373-859d-3a26df047799", "name": "eb64a4e4-6070-40ec-bc13-6a2922d7cd73", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c5372011-7783-401d-9a42-ba2d894a238e"}}}]}, {"uuid": "4d51d8cd-d0e6-4b8e-a4ad-5247983a09be", "name": "load_p1rlv7783_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd7a84bb-8aa4-4668-9791-a363741823e9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7dbdc0a2-3f64-4373-859d-3a26df047799"}}}}, {"uuid": "356fabb2-65b3-430b-a312-5aa18a3c401c", "name": "13d0f027-f3af-4bb2-82ae-f9bbfede334a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4212042062341066, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7562106926743815, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7341ff5f-3431-4fc3-8e0b-f52c7bc7373a", "name": "d5d33575-ebee-4695-b382-0da403d99f1f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "356fabb2-65b3-430b-a312-5aa18a3c401c"}}}]}, {"uuid": "e04e1abb-c60f-41f0-a774-c47db62edcb7", "name": "load_p1rlv7783_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd7a84bb-8aa4-4668-9791-a363741823e9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7341ff5f-3431-4fc3-8e0b-f52c7bc7373a"}}}}, {"uuid": "1713edaf-ac0f-44a1-98ba-b0cce436bc52", "name": "17302292-37b7-4d04-a4ad-5f84bccad702_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7101501378288513, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4527501720520811, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0199c07e-7ae5-4eae-8840-bc887b10f47c", "name": "21e0d40f-8044-479d-8281-30ccfe9937af", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1713edaf-ac0f-44a1-98ba-b0cce436bc52"}}}]}, {"uuid": "96a58958-439a-468e-b3d9-56cbf024da8c", "name": "load_p1rlv7784_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24e665a0-3ba6-46a7-bc02-327b6f77c409"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0199c07e-7ae5-4eae-8840-bc887b10f47c"}}}}, {"uuid": "dcdf6c24-e443-4d30-b513-55002574edab", "name": "b5c7351b-44db-4dad-a029-13aaf73a1b56_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7101501378288513, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4527501720520811, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "96ae4a60-29b4-4c2a-994d-969e5605b8e5", "name": "ba592037-68f9-4d58-8f80-54b47f0019dc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "dcdf6c24-e443-4d30-b513-55002574edab"}}}]}, {"uuid": "0dd29067-5363-4676-abfc-354c6ff02846", "name": "load_p1rlv7784_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24e665a0-3ba6-46a7-bc02-327b6f77c409"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "96ae4a60-29b4-4c2a-994d-969e5605b8e5"}}}}, {"uuid": "1f4bd4b8-5e77-4a63-b4ce-b7fb5e07d7d7", "name": "00369e15-8a8a-4925-b8e2-ab8a0b504b7f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7392455382108751, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4362253237121403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "810e40dc-14f6-45be-b35f-0f870f133692", "name": "5b77ab36-8077-415f-aa20-26ad0a9095f3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1f4bd4b8-5e77-4a63-b4ce-b7fb5e07d7d7"}}}]}, {"uuid": "b29d32c3-c841-4de0-a9bb-6c3bd598ecf0", "name": "load_p1rlv7785_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1571d1a3-a151-4972-8cb1-aeb36b660abc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "810e40dc-14f6-45be-b35f-0f870f133692"}}}}, {"uuid": "fe5e92cf-14d5-40c8-80c9-994efda6330b", "name": "2c63d8f0-6314-4200-907f-007d8fdc7b8a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7392455382108751, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4362253237121403, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8eb3fe60-7f0f-4d31-96ea-b471cece8da8", "name": "010de59b-39bf-4135-9331-e5121db1ff1d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fe5e92cf-14d5-40c8-80c9-994efda6330b"}}}]}, {"uuid": "491c2e8e-4768-402a-9265-b6aed108f402", "name": "load_p1rlv7785_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1571d1a3-a151-4972-8cb1-aeb36b660abc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8eb3fe60-7f0f-4d31-96ea-b471cece8da8"}}}}, {"uuid": "c4d52b83-c123-4dad-a510-e4e0acb90ef8", "name": "86cc9856-6517-480c-bd1f-5cb3042f8f64_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4818511326065424, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6748395523926414, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e73684a1-b61e-4422-a2d1-b6d0db4ad5cb", "name": "e55cf8bd-e951-4401-887c-da8167795169", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c4d52b83-c123-4dad-a510-e4e0acb90ef8"}}}]}, {"uuid": "199b5478-37e0-4ed6-8017-12a45432003a", "name": "load_p1rlv7786_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af62e3c-9357-4505-a2f6-3b4252dab81b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e73684a1-b61e-4422-a2d1-b6d0db4ad5cb"}}}}, {"uuid": "34a004b2-eea5-415a-8e47-262212d2a7d5", "name": "d016a180-f514-4118-b5ab-0bee72e27724_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4818511326065424, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6748395523926414, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "105167fd-90f0-40a8-a0b1-c598a4aff4a7", "name": "26f2e62d-d3bb-478c-b5ad-f367a0eca836", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "34a004b2-eea5-415a-8e47-262212d2a7d5"}}}]}, {"uuid": "3dd5337e-db69-4d76-b98f-47d0ed2a0fa6", "name": "load_p1rlv7786_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af62e3c-9357-4505-a2f6-3b4252dab81b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "105167fd-90f0-40a8-a0b1-c598a4aff4a7"}}}}, {"uuid": "98e8bc3a-ae30-47a4-b7d1-281b95a25c74", "name": "457cbb44-1f6e-4e4a-a8d2-a1c3fd8ad123_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9705664843982345, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20295664886439999, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10ff4285-30ed-41a3-8f7e-9ebc82a27b21", "name": "5374c77e-7f21-431e-a7b2-e576db6ca92a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "98e8bc3a-ae30-47a4-b7d1-281b95a25c74"}}}]}, {"uuid": "5377086a-e04a-491c-8e54-efd38306a144", "name": "load_p1rlv10453_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09926231-b077-4aa6-afd8-acf89744865a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10ff4285-30ed-41a3-8f7e-9ebc82a27b21"}}}}, {"uuid": "8a0a012e-28ce-42d7-a4bd-9ee349d700bc", "name": "25f0cc32-c195-40fb-83d4-0d08a5fdd278_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9705664843982345, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20295664886439999, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fbc1bd32-f7d7-4287-adfb-b99cc1a70bc5", "name": "d67682f3-c1e0-4618-abe0-2b29d2af39ff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8a0a012e-28ce-42d7-a4bd-9ee349d700bc"}}}]}, {"uuid": "bd7d0a1e-d67b-4a4e-a2c0-a7a1b73037af", "name": "load_p1rlv10453_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09926231-b077-4aa6-afd8-acf89744865a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fbc1bd32-f7d7-4287-adfb-b99cc1a70bc5"}}}}, {"uuid": "10730986-0710-4e81-990f-23beb309d894", "name": "c2d3e7d3-19b1-44f4-b6fa-b8cd5157c579_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9288135994675786, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3237835349774649, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4db3bb81-f55f-4f61-a851-1a862c76b727", "name": "58e3f632-f96c-40e1-a83e-23ef309dba25", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "10730986-0710-4e81-990f-23beb309d894"}}}]}, {"uuid": "3a7f5ff3-b2dd-454a-99fc-5b591d560ba5", "name": "load_p1rlv10468_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a639e8d-ac8c-46e8-a4b5-6c551612b209"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4db3bb81-f55f-4f61-a851-1a862c76b727"}}}}, {"uuid": "c7776e75-cfc5-4157-8f3a-7503c9711283", "name": "20e4f9b1-b0fa-458b-b0ce-e9170c32f91d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9288135994675786, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3237835349774649, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a6dc196c-5ae1-4ab2-805f-2810cbff7632", "name": "5083f26e-7835-4fd1-93f4-b27ec12194b4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c7776e75-cfc5-4157-8f3a-7503c9711283"}}}]}, {"uuid": "339c7105-f33b-45e5-abcf-ef13c4974cbf", "name": "load_p1rlv10468_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a639e8d-ac8c-46e8-a4b5-6c551612b209"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a6dc196c-5ae1-4ab2-805f-2810cbff7632"}}}}, {"uuid": "c1025d61-e42a-41dd-8a3c-2bb129424d05", "name": "a10cf00c-67ac-4213-ad57-a683b93ef409_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.137360281336931, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.443734948632237, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c8407680-4514-4a23-a4e1-14107c4aa215", "name": "00e230a2-ffb8-423f-88ad-611c74946da7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c1025d61-e42a-41dd-8a3c-2bb129424d05"}}}]}, {"uuid": "d5c520ff-f7a9-48be-870b-1d2208006878", "name": "load_p1rlv10482_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d40fc87f-1b73-4ed4-a397-dbc94312dcad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c8407680-4514-4a23-a4e1-14107c4aa215"}}}}, {"uuid": "6634dc96-29a7-43b5-81a6-334cba43847c", "name": "e237970c-6462-4344-af07-c9d1ad1343a4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.137360281336931, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.443734948632237, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e887fdb7-614b-4d04-b57a-0d1cc3fd571e", "name": "00e2e47e-f8b0-489e-947f-2a9f364dce18", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6634dc96-29a7-43b5-81a6-334cba43847c"}}}]}, {"uuid": "997faa1f-d5f7-441a-869d-4e69da540525", "name": "load_p1rlv10482_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d40fc87f-1b73-4ed4-a397-dbc94312dcad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e887fdb7-614b-4d04-b57a-0d1cc3fd571e"}}}}, {"uuid": "fe4be1fd-0512-4eb7-9f7f-11886ff23ff1", "name": "64750c64-f3ba-45b1-816b-750e7b1e9b4d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.982015016710447, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5720113989287618, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "078f82f7-4f75-410d-a499-337abb2ebaac", "name": "3e87d6fc-2a31-40a4-9ce4-830ded723b7a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fe4be1fd-0512-4eb7-9f7f-11886ff23ff1"}}}]}, {"uuid": "cca90958-3097-4288-b429-b28e1fd1caf7", "name": "load_p1rlv10517_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "efd01236-6ba3-424e-829b-3f3950ce6265"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "078f82f7-4f75-410d-a499-337abb2ebaac"}}}}, {"uuid": "a170ae41-2689-494f-aa57-d9df60f90d08", "name": "c9c3960e-61bf-4a9b-bba7-44c9143e27e6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.982015016710447, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5720113989287618, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "269b3854-5224-400f-839d-f2b589390694", "name": "d192040d-7e21-4a69-b5fb-8ea8137bca90", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a170ae41-2689-494f-aa57-d9df60f90d08"}}}]}, {"uuid": "36344287-a32a-46aa-a960-835474341ea3", "name": "load_p1rlv10517_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "efd01236-6ba3-424e-829b-3f3950ce6265"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "269b3854-5224-400f-839d-f2b589390694"}}}}, {"uuid": "adcf0a93-9a94-431d-9ebc-6835e5a8059a", "name": "2036e332-5afc-465e-9d87-d99c6f411b95_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.160991762543576, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9056130261441641, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2c486189-5467-480d-a6ad-ae7c6290458c", "name": "eaabd49c-a213-4fd5-9cca-291701c002fa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "adcf0a93-9a94-431d-9ebc-6835e5a8059a"}}}]}, {"uuid": "65822cb1-153e-4fbc-8610-1b9fc2dc485c", "name": "load_p1rlv11503_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "773a6b9e-d708-4f7c-a901-9406bcc3dcde"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2c486189-5467-480d-a6ad-ae7c6290458c"}}}}, {"uuid": "6799b0b2-e42f-4ddc-bc71-b87a75fc8f59", "name": "edc9e2eb-7c62-47ab-ba2c-c1119079824a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.160991762543576, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9056130261441641, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c30fe11c-27f9-4a6f-8a66-50f3396162a4", "name": "834f3ff6-6233-4dd4-a5a0-dafe3f984f1b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6799b0b2-e42f-4ddc-bc71-b87a75fc8f59"}}}]}, {"uuid": "6949907d-ea62-46ba-b015-cc5a3054b94b", "name": "load_p1rlv11503_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "773a6b9e-d708-4f7c-a901-9406bcc3dcde"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c30fe11c-27f9-4a6f-8a66-50f3396162a4"}}}}, {"uuid": "320bb1ad-fb4a-4e8a-991d-a2cef4662f2b", "name": "45904608-adc0-44ee-b20b-377a44260f1c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 15.606876661659024, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.2167580478298823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a224ecb-4f16-4ea5-8f6f-384ece3a523c", "name": "45904608-adc0-44ee-b20b-377a44260f1c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 15.606876661659024, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.2167580478298823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "68e57e33-9943-44b8-b264-b5560c1d4b4c", "name": "45904608-adc0-44ee-b20b-377a44260f1c_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 15.606876661659024, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.2167580478298823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4748482d-bd45-4d2c-870e-3fb5e1a21449", "name": "a4709721-35d1-451c-abcd-4ef6fdbb9e7c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "320bb1ad-fb4a-4e8a-991d-a2cef4662f2b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0a224ecb-4f16-4ea5-8f6f-384ece3a523c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "68e57e33-9943-44b8-b264-b5560c1d4b4c"}}}]}, {"uuid": "1c4e8311-a62b-4a80-b43d-dc5ded5311c3", "name": "load_p1rlv11506", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "82988650-787d-41de-bca7-4f3c08ccad15"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4748482d-bd45-4d2c-870e-3fb5e1a21449"}}}}, {"uuid": "95c9105d-b00f-4e2d-932b-b74067800d34", "name": "cefbed57-dfef-4d79-b045-a385ca1060a0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 10.178690882168185, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.8011442962112136, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4addb2d3-a678-4527-be47-baab300fcbc5", "name": "1bf14111-5b0a-48df-9573-c9b4a0915629", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "95c9105d-b00f-4e2d-932b-b74067800d34"}}}]}, {"uuid": "be46345e-157c-4ee5-8acb-761ea129e52c", "name": "load_p1rlv11513_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84b9d44e-2c8d-4cee-a9d2-327a41ab8dad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4addb2d3-a678-4527-be47-baab300fcbc5"}}}}, {"uuid": "a8ab0468-5638-4f7a-8350-694c2857b3b2", "name": "abaaafc3-3725-42e3-a946-bd918dcaad8f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 10.178690882168185, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.8011442962112136, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ec915dd7-5306-43d9-aa73-5e9131b64835", "name": "c54f0076-4198-48b3-b38d-657bf46d4e2e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a8ab0468-5638-4f7a-8350-694c2857b3b2"}}}]}, {"uuid": "622a3b87-1a77-42d7-ba31-d9a7b2703765", "name": "load_p1rlv11513_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84b9d44e-2c8d-4cee-a9d2-327a41ab8dad"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ec915dd7-5306-43d9-aa73-5e9131b64835"}}}}, {"uuid": "c66757e7-156b-47a2-bf3c-60b350e5671b", "name": "227d777e-40c2-48b4-90bb-65961da9a105_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2659851154673674, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7880475847724098, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0b50e2b1-205e-433c-9316-e198d133f206", "name": "54b20506-3d9b-4132-851d-4475eebc75b2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c66757e7-156b-47a2-bf3c-60b350e5671b"}}}]}, {"uuid": "a94a1d11-35e4-461d-ba20-7085e88df6a2", "name": "load_p1rlv11516_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86d82a1e-1596-4fb3-9f3d-44c9553396d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0b50e2b1-205e-433c-9316-e198d133f206"}}}}, {"uuid": "9cb4e692-7ff1-4d87-82a1-033a7139968e", "name": "791e23e8-102a-43c4-baa3-d5c8ae44f2d8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2659851154673674, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7880475847724098, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d679bb72-207d-4856-892d-58dd46d23339", "name": "c7194d59-734a-4c7d-839b-5429638241f6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9cb4e692-7ff1-4d87-82a1-033a7139968e"}}}]}, {"uuid": "050ba298-c20a-4ec0-beb3-b94e3808c5ec", "name": "load_p1rlv11516_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86d82a1e-1596-4fb3-9f3d-44c9553396d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d679bb72-207d-4856-892d-58dd46d23339"}}}}, {"uuid": "e89a76ae-f8b2-42fb-a46a-b59b5774aa94", "name": "10fb628e-fe01-4f5b-b631-dd5fda3853b9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.902887215219663, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.111231385342157, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10ea2792-e7fa-4609-8180-c5ffb4d298ea", "name": "e8c790b6-8571-498c-b018-36135359b8db", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e89a76ae-f8b2-42fb-a46a-b59b5774aa94"}}}]}, {"uuid": "8299b35d-b954-47de-8828-e54a4b3d5896", "name": "load_p1rlv11517_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "179d1d84-0dfe-4920-a039-009f33bc1d8d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10ea2792-e7fa-4609-8180-c5ffb4d298ea"}}}}, {"uuid": "9653af9d-2182-458d-b7b2-1dc199a9116d", "name": "6017e7e0-c29c-4d8b-8bde-e5e9ca1f6340_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.902887215219663, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.111231385342157, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a479e565-1151-4019-80aa-a642f090d9be", "name": "0ab2c7d4-ca0c-4bcc-af61-7866d7984102", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9653af9d-2182-458d-b7b2-1dc199a9116d"}}}]}, {"uuid": "b740edad-3e1a-4df3-afce-70e52538d492", "name": "load_p1rlv11517_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "179d1d84-0dfe-4920-a039-009f33bc1d8d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a479e565-1151-4019-80aa-a642f090d9be"}}}}, {"uuid": "bccabf64-2cc5-4387-9063-037efea74407", "name": "1861f9e2-4187-4864-b570-207cc6126bb6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.815209062299411, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.284220525554307, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7f72e181-164e-4eca-9e0b-189f57e4a521", "name": "1861f9e2-4187-4864-b570-207cc6126bb6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.815209062299411, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.284220525554307, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d62011ec-36d9-4fd0-b81f-4d5f7e76902d", "name": "1861f9e2-4187-4864-b570-207cc6126bb6_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 9.815209062299411, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.284220525554307, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "615c3356-445c-4f98-b970-8b8bcf87321c", "name": "e30959d0-13f7-44fe-86ec-b383372d22e1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bccabf64-2cc5-4387-9063-037efea74407"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7f72e181-164e-4eca-9e0b-189f57e4a521"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d62011ec-36d9-4fd0-b81f-4d5f7e76902d"}}}]}, {"uuid": "2948aa17-5f03-4d92-9ea6-60b285cfde09", "name": "load_p1rlv11520", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22054033-4e69-41b0-b321-a4d086d20574"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "615c3356-445c-4f98-b970-8b8bcf87321c"}}}}, {"uuid": "376e485b-5ffb-4d5a-ab9c-64c132605a26", "name": "0650d81b-3963-4552-9f0d-b6acae375567_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.368937976023913, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.122061037955929, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e7fbaefc-92c8-4fa6-a238-3e6675385749", "name": "6d7f0b7e-8a13-40aa-91d7-3116020e24e4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "376e485b-5ffb-4d5a-ab9c-64c132605a26"}}}]}, {"uuid": "24ac8477-c762-4578-83f9-36c4764ce044", "name": "load_p1rlv11521_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8f0f8a2-f528-45bd-8fbd-22f6699fe7e0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e7fbaefc-92c8-4fa6-a238-3e6675385749"}}}}, {"uuid": "caae9a53-cd7f-4831-9508-c2fee2b76934", "name": "0a722b1d-473f-4b6c-95f4-4fbd79aa4363_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.368937976023913, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.122061037955929, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f0b2e0be-2a69-47bc-afc9-0bb2f64630a5", "name": "b13519da-e21b-4c44-92a3-01a34458956d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "caae9a53-cd7f-4831-9508-c2fee2b76934"}}}]}, {"uuid": "80fb38d5-a103-45ea-86fb-d8189b370241", "name": "load_p1rlv11521_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8f0f8a2-f528-45bd-8fbd-22f6699fe7e0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f0b2e0be-2a69-47bc-afc9-0bb2f64630a5"}}}}, {"uuid": "4fed72ed-a1e0-4262-aaaf-9c856ccf37b2", "name": "52385853-2633-446a-b93e-aa1b1774eb15_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.71666338297624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.8739990837811158, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0aae9508-102f-4e20-96f8-94b35ed671f6", "name": "52385853-2633-446a-b93e-aa1b1774eb15_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.71666338297624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.8739990837811158, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cc9d9e94-7981-4ee8-bcbf-f5701ba564c1", "name": "52385853-2633-446a-b93e-aa1b1774eb15_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.71666338297624, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.8739990837811158, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2a91d892-91c6-46ae-8e47-a9f3b59fc4eb", "name": "41d8b914-1843-44e5-9884-4acfb3532ffa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4fed72ed-a1e0-4262-aaaf-9c856ccf37b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0aae9508-102f-4e20-96f8-94b35ed671f6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cc9d9e94-7981-4ee8-bcbf-f5701ba564c1"}}}]}, {"uuid": "c6a2d41d-89f4-40a1-ae53-15df7b87dd3d", "name": "load_p1rlv11522", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "176b348f-9ecf-4a82-bdf9-f2e5d5a07af7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2a91d892-91c6-46ae-8e47-a9f3b59fc4eb"}}}}, {"uuid": "2e1897ab-fffe-4051-9e23-ec687c8aef6d", "name": "c465d6c6-c4fd-4311-bd32-332bd93cf1cb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 20.596071016561904, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.1080231298812775, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2c067e42-b521-4917-b01a-4328455c627c", "name": "e109b65b-daae-4732-99bc-a5349c5862f2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2e1897ab-fffe-4051-9e23-ec687c8aef6d"}}}]}, {"uuid": "f928863f-0387-490e-b720-40d3ac320fcc", "name": "load_p1rlv11523_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69eba934-3f80-4abc-b5e8-9cdc79aa05a3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2c067e42-b521-4917-b01a-4328455c627c"}}}}, {"uuid": "e0a9ad2d-dbd1-4237-b3e2-5ec5a2c10f3a", "name": "9bcd81db-6dfb-40ba-bf8d-fd41202caeaf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 20.596071016561904, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.1080231298812775, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4899fddb-d844-4080-b45a-7bccd4a40de6", "name": "994ac187-1add-4de4-94e1-448e7bd00ee9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e0a9ad2d-dbd1-4237-b3e2-5ec5a2c10f3a"}}}]}, {"uuid": "a80e2788-c6e3-46ce-955b-5bef549c5386", "name": "load_p1rlv11523_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69eba934-3f80-4abc-b5e8-9cdc79aa05a3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4899fddb-d844-4080-b45a-7bccd4a40de6"}}}}, {"uuid": "65d4d5d7-783c-4164-9c8c-6c80d4c32877", "name": "fbee6fff-73fa-44c2-88bb-e8f585e06115_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.560490892963857, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.302618625091914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10815e19-d32c-4147-a949-9fef4a5bc497", "name": "4ab78c27-a37e-49bf-b595-8b2419cac41f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "65d4d5d7-783c-4164-9c8c-6c80d4c32877"}}}]}, {"uuid": "d8524e9d-cf8b-47cd-92c0-a98c04a69555", "name": "load_p1rlv11526_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b97ebb0-09a4-4c42-a10e-e3aff344aa44"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10815e19-d32c-4147-a949-9fef4a5bc497"}}}}, {"uuid": "51e5b752-3e23-46c1-9104-8d1d07336b1f", "name": "088aeaee-f16d-455b-b6d9-55ceb9ab8cb3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 8.560490892963857, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.302618625091914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d2e76bd6-ce54-4e45-afc2-c40a892add08", "name": "88cdaf35-1444-46f0-8a69-9a7b75dfe1b2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "51e5b752-3e23-46c1-9104-8d1d07336b1f"}}}]}, {"uuid": "262f3cf0-072f-4bb0-ae69-bed19095daee", "name": "load_p1rlv11526_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b97ebb0-09a4-4c42-a10e-e3aff344aa44"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d2e76bd6-ce54-4e45-afc2-c40a892add08"}}}}, {"uuid": "081b87d0-9953-4e94-a14c-6869f5aff188", "name": "9e28f35b-2950-4018-b931-ce4c4c0e68c5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.930214175792893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.08514782397789, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c4f46244-6662-4298-a101-badc385e322a", "name": "a13bffde-fdec-4d49-9362-91ba5f7576b4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "081b87d0-9953-4e94-a14c-6869f5aff188"}}}]}, {"uuid": "9a43a335-3b65-4527-a2e0-01cfe39458a8", "name": "load_p1rlv11533_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21b18539-fba6-4b52-b8bf-38c2a6c4abfb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c4f46244-6662-4298-a101-badc385e322a"}}}}, {"uuid": "99521e7b-f1a6-438c-98d8-173782182e76", "name": "bab3eb24-732d-46b7-8d01-cd470539adfe_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.930214175792893, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.08514782397789, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4fd952c7-7b2a-4e24-9952-342418d3823b", "name": "9ff22554-db4e-4376-8f63-da8436d1a4e4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "99521e7b-f1a6-438c-98d8-173782182e76"}}}]}, {"uuid": "8b08b8fd-c3d6-4cf2-84f5-3a95d96b51ad", "name": "load_p1rlv11533_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21b18539-fba6-4b52-b8bf-38c2a6c4abfb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4fd952c7-7b2a-4e24-9952-342418d3823b"}}}}, {"uuid": "ddf295d3-4ca7-45b8-bab0-2d2bedc79adf", "name": "164eb96d-8724-440d-841e-984dfc18b446_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.679125701108364, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8113232260660387, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "11b71362-a9ff-4ef3-91d7-b68749e0d98c", "name": "ae9b73d9-29a3-4d82-a958-b574c12d172e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ddf295d3-4ca7-45b8-bab0-2d2bedc79adf"}}}]}, {"uuid": "0920b786-6c42-4116-a887-236dade23449", "name": "load_p1rlv11540_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f79b14c8-e77d-49c1-9336-e7407ad4c94d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "11b71362-a9ff-4ef3-91d7-b68749e0d98c"}}}}, {"uuid": "8e30adb3-f06b-4cd3-bb78-0d53c73b9a12", "name": "a65e0dea-444d-422c-859a-f131dddcc40d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.679125701108364, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8113232260660387, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5b1b211b-f5c6-4161-9358-4937f7abcf73", "name": "9a4b4965-a41b-4d43-a8a7-48fa3accb31f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8e30adb3-f06b-4cd3-bb78-0d53c73b9a12"}}}]}, {"uuid": "e4f076a8-8c21-4468-995f-cb3d3a523c31", "name": "load_p1rlv11540_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f79b14c8-e77d-49c1-9336-e7407ad4c94d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5b1b211b-f5c6-4161-9358-4937f7abcf73"}}}}, {"uuid": "4fa4e50c-0268-4490-9d23-af532cb741af", "name": "ed9a947f-533f-4db7-9220-295975ae80ed_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c32e1d70-5898-46d9-bdfe-474a13392868", "name": "68ccf7df-d110-494b-be42-8264b9530d4d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4fa4e50c-0268-4490-9d23-af532cb741af"}}}]}, {"uuid": "4c5802e3-88ed-4e3e-929b-910aeb4c85f1", "name": "load_p1rlv13033_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1564c5f9-8b80-41b4-af09-2a55dee0718b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c32e1d70-5898-46d9-bdfe-474a13392868"}}}}, {"uuid": "ce96a1c1-4da1-4feb-ab24-94101677e52a", "name": "ac092c22-a341-4f4b-8b0e-06392057556b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.6889246320671938, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.43643880816342934, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "629c4abf-b246-4c2f-be64-fc45ce958904", "name": "2dca5672-682f-4a17-8c6a-9c7e92a4b7c3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ce96a1c1-4da1-4feb-ab24-94101677e52a"}}}]}, {"uuid": "ad7a7ba1-03a7-421c-af74-453a372d2ea2", "name": "load_p1rlv13033_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1564c5f9-8b80-41b4-af09-2a55dee0718b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "629c4abf-b246-4c2f-be64-fc45ce958904"}}}}, {"uuid": "c09b2358-e1d4-413e-b86c-89d5aeea06c6", "name": "709debc3-2c8b-473c-b17c-aa380a193726_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.074192704000552, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.129078804753558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a399b34-ceb0-4ca8-ab6b-fbeb5d6f11c7", "name": "2f4af060-e488-4b5c-bbdc-53115064906c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c09b2358-e1d4-413e-b86c-89d5aeea06c6"}}}]}, {"uuid": "8a1dd38f-312a-47da-905c-79698fc4f27c", "name": "load_p1rlv13034_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3b7bff1-90da-4ee2-8a0f-8e291a7e8ac8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a399b34-ceb0-4ca8-ab6b-fbeb5d6f11c7"}}}}, {"uuid": "223ca125-2a2e-42c1-a0f0-1828dd36ffba", "name": "5cbc8aa5-1d48-4762-9892-454566c93f99_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.074192704000552, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.129078804753558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a6972633-51d9-4e1e-be81-d289073144bd", "name": "4f0c4078-005c-4e05-a7c1-0bc96ee69bb0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "223ca125-2a2e-42c1-a0f0-1828dd36ffba"}}}]}, {"uuid": "fb379ee7-427c-476e-ac35-a702194e4e69", "name": "load_p1rlv13034_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3b7bff1-90da-4ee2-8a0f-8e291a7e8ac8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a6972633-51d9-4e1e-be81-d289073144bd"}}}}, {"uuid": "138ba538-6925-4490-b7f9-acb50c759789", "name": "3c7fb123-b99c-46f9-9eec-1cafe1d9f2e8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8791002615066037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24190904367644575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50264ea1-2130-4ac4-8d83-06f7624bd00e", "name": "44c01c96-1d1c-4b12-a737-fa38d53e233c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "138ba538-6925-4490-b7f9-acb50c759789"}}}]}, {"uuid": "349eb58c-b111-4f6d-92c2-159ecb9b146c", "name": "load_p1rlv13035_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6d309ef-b082-4022-a265-4891cdcd6db9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50264ea1-2130-4ac4-8d83-06f7624bd00e"}}}}, {"uuid": "b87dfe47-5295-4a04-b72a-5be002a781e1", "name": "6e915124-e0ea-436f-9543-a77188bab4cd_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8791002615066037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24190904367644575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2fa5a665-5deb-467b-bc9f-e71f2bfdf9cf", "name": "bee7ab42-c47c-4c2f-8de9-ccab5a61c6bf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b87dfe47-5295-4a04-b72a-5be002a781e1"}}}]}, {"uuid": "e46287b6-7827-4592-b1f2-e687e6f7c00a", "name": "load_p1rlv13035_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6d309ef-b082-4022-a265-4891cdcd6db9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2fa5a665-5deb-467b-bc9f-e71f2bfdf9cf"}}}}, {"uuid": "b1401c39-ec75-4e7a-8caa-59de8c4e3727", "name": "7ec60f8a-d974-4b77-92e3-6cbdb06326b0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.131827489381682, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6495252596209705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "99ced9d6-782f-4da9-9093-b8b75d9454c2", "name": "19e9f87e-4cc7-4702-8545-744ffab5f522", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b1401c39-ec75-4e7a-8caa-59de8c4e3727"}}}]}, {"uuid": "74249f5e-7c0c-44ef-a2be-d9cadb9b8d06", "name": "load_p1rlv13036_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23aae8f1-8b9f-4453-9643-b49ffdc80889"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "99ced9d6-782f-4da9-9093-b8b75d9454c2"}}}}, {"uuid": "bb7a935e-ef3f-4259-9dce-2efb49419534", "name": "8451fc2b-9ede-464e-80ad-cec49e4e429f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.131827489381682, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6495252596209705, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5a4776db-fe9d-4c72-b386-e630b5d5e0c9", "name": "c75f3183-02be-4b10-b581-a012f3bdcff2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bb7a935e-ef3f-4259-9dce-2efb49419534"}}}]}, {"uuid": "d0d08220-f82e-4813-9e86-d7f5cb6054e5", "name": "load_p1rlv13036_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23aae8f1-8b9f-4453-9643-b49ffdc80889"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5a4776db-fe9d-4c72-b386-e630b5d5e0c9"}}}}, {"uuid": "77d82711-d253-462f-9ce5-586d5710551c", "name": "d87b062f-7549-4bee-af82-d39450b08042_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5976710782342964, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7583664749710641, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "671b0544-3d59-4a1b-8ec2-057c16dd2d81", "name": "05306373-07f2-441b-a327-a67270b22e0d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "77d82711-d253-462f-9ce5-586d5710551c"}}}]}, {"uuid": "15c35e98-5054-4b11-b7b4-e8429f0b12fc", "name": "load_p1rlv13037_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f5d04aa-74fb-4d1a-ac91-6c01a56a94b5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "671b0544-3d59-4a1b-8ec2-057c16dd2d81"}}}}, {"uuid": "f31d5dca-c798-4cd4-b33b-6ef36ff34bc7", "name": "7dbc7a03-397e-4144-b496-f0c6fa124214_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5976710782342964, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7583664749710641, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a3e03fb2-566e-4710-a10c-7991ba3eeca0", "name": "4280b610-705e-4bf3-ba2f-30e609aa9084", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f31d5dca-c798-4cd4-b33b-6ef36ff34bc7"}}}]}, {"uuid": "1cd6f0e8-61a1-4056-9be8-650d4ddfb3c8", "name": "load_p1rlv13037_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f5d04aa-74fb-4d1a-ac91-6c01a56a94b5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a3e03fb2-566e-4710-a10c-7991ba3eeca0"}}}}, {"uuid": "79a2c1dd-04cb-47c4-aea3-5ad30f4dd768", "name": "635abd80-13c7-475c-af2d-43f4c81f0b5c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3798783675992279, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6151141774255103, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "74679bbb-a484-4253-95c3-882a57fe12a8", "name": "7a58bd99-3ac7-4f56-92ae-cdd643b0c927", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "79a2c1dd-04cb-47c4-aea3-5ad30f4dd768"}}}]}, {"uuid": "5502f1c8-b1b7-4e4b-a292-e5983d56926a", "name": "load_p1rlv13038_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a8b4502-31fd-4dce-8717-9860880075b4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "74679bbb-a484-4253-95c3-882a57fe12a8"}}}}, {"uuid": "8ad46779-2f5a-4b34-9123-594b28c7eef7", "name": "5dce28a7-bf93-405d-8b27-8d86926ff647_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3798783675992279, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6151141774255103, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fe24ccb4-a072-4c0e-9c69-7397187c0cf7", "name": "4477297e-dda0-42e2-bb36-9d0b9e1a7d1a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ad46779-2f5a-4b34-9123-594b28c7eef7"}}}]}, {"uuid": "b4ade9d1-a099-4144-8c8f-1313629a488b", "name": "load_p1rlv13038_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a8b4502-31fd-4dce-8717-9860880075b4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fe24ccb4-a072-4c0e-9c69-7397187c0cf7"}}}}, {"uuid": "f0d3a250-3125-47eb-beed-cb4d47fa06b4", "name": "177b4262-69d7-456e-a722-ddb895f56358_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9179777962446224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3481400399277513, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4bbd2f71-2995-4f3a-8fa8-bbdbc13b5f7b", "name": "e4ad0457-669c-4703-8935-20a525526720", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f0d3a250-3125-47eb-beed-cb4d47fa06b4"}}}]}, {"uuid": "8016b94a-61cd-4674-9c60-0410c68b8445", "name": "load_p1rlv13039_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34d43081-e4a3-4f1b-8b90-5965458452d0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4bbd2f71-2995-4f3a-8fa8-bbdbc13b5f7b"}}}}, {"uuid": "07e8ba08-4868-403a-8a82-8ca90c974837", "name": "b8559d4c-4ddd-4d69-af4d-82e49146b816_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9179777962446224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3481400399277513, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4d0f1690-75ce-4f79-9841-9acb4c42984c", "name": "5287314b-d1e0-4ade-b0b3-387b6329da2c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "07e8ba08-4868-403a-8a82-8ca90c974837"}}}]}, {"uuid": "b9f95b3b-f26e-4c6a-a080-a497e15d7e02", "name": "load_p1rlv13039_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34d43081-e4a3-4f1b-8b90-5965458452d0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4d0f1690-75ce-4f79-9841-9acb4c42984c"}}}}, {"uuid": "e29843ac-90b9-437c-9117-ccf066515291", "name": "29e3febd-4892-42b4-b287-c9ebfb418d08_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4464370236076721, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16599396793014964, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "03f4d81e-7c78-4db0-89f5-bee053df019a", "name": "d4430213-5d8e-4f92-af83-09a386b39a7e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e29843ac-90b9-437c-9117-ccf066515291"}}}]}, {"uuid": "c9b00953-9433-444e-a5c9-287baab06620", "name": "load_p1rlv13040_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6839f65-9d3b-4bd6-89a4-0c8feb33e98a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "03f4d81e-7c78-4db0-89f5-bee053df019a"}}}}, {"uuid": "2e0477a3-1ea7-4d91-81c7-3e83d4dea658", "name": "ecf11542-81c2-4406-a311-e724aa04cf7a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4464370236076721, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16599396793014964, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ddcc766b-ec42-4d26-bd83-7ddc9efec038", "name": "8083a4d1-79d3-4022-9268-102584301916", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2e0477a3-1ea7-4d91-81c7-3e83d4dea658"}}}]}, {"uuid": "09a05117-9020-4a21-8ab8-0ef14c99c774", "name": "load_p1rlv13040_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6839f65-9d3b-4bd6-89a4-0c8feb33e98a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ddcc766b-ec42-4d26-bd83-7ddc9efec038"}}}}, {"uuid": "9fd53137-bf5a-4f5f-a0b4-8276d87bb04e", "name": "6c17db69-bff2-4e56-a3c1-bb3723cd6918_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6434260893942235, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2588956175598443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3782e5b3-e7f7-4d7f-b4b4-58875e227199", "name": "f2e69ca8-aaf9-43be-9bee-272320ab0e80", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9fd53137-bf5a-4f5f-a0b4-8276d87bb04e"}}}]}, {"uuid": "1e04bc67-8ff5-44ca-8784-51571cb550f5", "name": "load_p1rlv13041_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60144ce1-d4d6-4725-b543-f881894356a5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3782e5b3-e7f7-4d7f-b4b4-58875e227199"}}}}, {"uuid": "30335b57-8e08-4154-960d-cdb9c5ede14d", "name": "6231824f-1b85-4d24-800d-f11202944c11_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6434260893942235, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2588956175598443, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "119a9724-a20e-416d-809e-b714471622b9", "name": "184a31ea-7142-4290-9059-ff71e29618bd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "30335b57-8e08-4154-960d-cdb9c5ede14d"}}}]}, {"uuid": "d020a635-aab4-4f6b-83b6-a53650efb072", "name": "load_p1rlv13041_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60144ce1-d4d6-4725-b543-f881894356a5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "119a9724-a20e-416d-809e-b714471622b9"}}}}, {"uuid": "55db8cce-9446-48f3-8af9-62589b3bd742", "name": "b428e6d6-918d-4b4d-971d-7391125b8f9b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4148353854888571, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6393114443430603, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "294d20fe-cf8c-46f0-9f89-0657ecce2434", "name": "deaccebf-96cd-40dd-b573-7ca8f71d8aa1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "55db8cce-9446-48f3-8af9-62589b3bd742"}}}]}, {"uuid": "d794cf69-32cb-405e-aea3-c90086351290", "name": "load_p1rlv13042_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "296cd07e-c2e3-4031-abad-9c870a65105d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "294d20fe-cf8c-46f0-9f89-0657ecce2434"}}}}, {"uuid": "9eb257c7-77e7-41ba-b202-3ff32c0bae0f", "name": "32b13cdb-a6a7-4fa4-9149-82f44136ffe0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4148353854888571, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6393114443430603, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bd71a0f0-6c1d-48ed-bf4a-8de6a137936e", "name": "8f98108c-29bd-4c2f-ad46-00c13335eece", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9eb257c7-77e7-41ba-b202-3ff32c0bae0f"}}}]}, {"uuid": "3d035aed-8608-46c0-983e-7d889e4949f9", "name": "load_p1rlv13042_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "296cd07e-c2e3-4031-abad-9c870a65105d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bd71a0f0-6c1d-48ed-bf4a-8de6a137936e"}}}}, {"uuid": "425e2de3-13e4-4801-a064-4d6ab2e349ce", "name": "2aafb20a-ab3e-4270-8650-395ae93416dd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.478593979285423, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7308840963144931, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "291002f8-5c77-41b0-b8e0-60cd4dbfc1da", "name": "e96ce69e-4a0b-451e-beb7-464af7b99a7f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "425e2de3-13e4-4801-a064-4d6ab2e349ce"}}}]}, {"uuid": "f7547184-7196-4c0c-9432-e18539ec7017", "name": "load_p1rlv13513_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3243ca2f-a97e-4fbc-981d-85eded2e5e6b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "291002f8-5c77-41b0-b8e0-60cd4dbfc1da"}}}}, {"uuid": "fed2bcf4-ae62-4152-aa92-ec9cbf205825", "name": "f582a945-a569-495f-b213-31a28a011ac9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.478593979285423, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7308840963144931, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f12ac523-0ead-4cbf-969c-b26ceaaeec58", "name": "eb431eed-b218-4601-9fa7-f4a8dabafcff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fed2bcf4-ae62-4152-aa92-ec9cbf205825"}}}]}, {"uuid": "737befe8-c05e-4ae8-baf6-f2e2a1d20f28", "name": "load_p1rlv13513_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3243ca2f-a97e-4fbc-981d-85eded2e5e6b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f12ac523-0ead-4cbf-969c-b26ceaaeec58"}}}}, {"uuid": "1a5b8ef6-4d4b-4207-aaae-0b8a6562ae2c", "name": "e127eac9-8755-4774-a29d-89f9e6b418a0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.516258392707745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.82351986644914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "03330f10-9cb3-42e2-aef8-e02084fc5dec", "name": "a8790ecc-0157-4088-82d4-7aa10c681ebb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1a5b8ef6-4d4b-4207-aaae-0b8a6562ae2c"}}}]}, {"uuid": "059c3995-844d-453c-932d-52647f7dbc4c", "name": "load_p1rlv13789_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47a7519a-b550-41e6-99e3-c2115db425fe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "03330f10-9cb3-42e2-aef8-e02084fc5dec"}}}}, {"uuid": "2e22c9e7-f048-46f8-bc69-5861cfd05527", "name": "8c2a521a-38cb-4686-8fa9-386999634546_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.516258392707745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.82351986644914, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eae585db-5e8d-4d76-8203-27d0420f79b4", "name": "188cd438-df8d-4b24-b92d-fddfbb0a2ebe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2e22c9e7-f048-46f8-bc69-5861cfd05527"}}}]}, {"uuid": "5cf01015-ea31-4da1-939a-778efe5c2762", "name": "load_p1rlv13789_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47a7519a-b550-41e6-99e3-c2115db425fe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eae585db-5e8d-4d76-8203-27d0420f79b4"}}}}, {"uuid": "15995836-e2ba-4cf9-b118-fff27f395444", "name": "a6f8ebb6-0854-4d92-9356-401305b2a257_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3786182488338723, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5359363058124609, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6151c915-f4c7-4240-b24d-ee4967125fff", "name": "08169670-c1b9-4102-9b44-fc13d2303d0c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "15995836-e2ba-4cf9-b118-fff27f395444"}}}]}, {"uuid": "4e713549-1fcf-420c-ba99-1a57feebc8e5", "name": "load_p1rlv13791_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "251f270f-4238-4fe6-8ab3-f884fca7a42d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6151c915-f4c7-4240-b24d-ee4967125fff"}}}}, {"uuid": "7dfb398c-2767-42a5-a503-e4c1a92dab37", "name": "787f56e7-2686-4704-aafa-30bc043d4c7d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3786182488338723, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5359363058124609, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "01d1aabe-0a01-4e59-a48f-7c981a2fdc1a", "name": "22519096-b6e1-40e2-975d-736497e787ed", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7dfb398c-2767-42a5-a503-e4c1a92dab37"}}}]}, {"uuid": "db355cce-248a-4b61-815d-b564ae9f0424", "name": "load_p1rlv13791_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "251f270f-4238-4fe6-8ab3-f884fca7a42d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "01d1aabe-0a01-4e59-a48f-7c981a2fdc1a"}}}}, {"uuid": "5b2c074c-c20e-4eab-b9a8-e92b48974001", "name": "8fde2c8d-0b7d-43c0-b5e3-9724c9e6f07c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4950137537296666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31506625700854357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5c88bd25-3fea-4b53-a5c3-29d534c2286e", "name": "86a0e8fc-47a8-451c-b70d-2cb2c944eb6e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b2c074c-c20e-4eab-b9a8-e92b48974001"}}}]}, {"uuid": "2bb93d01-77c6-4fb0-b5b0-918cc6184ea8", "name": "load_p1rlv13796_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94ac9254-cdbf-4864-b22b-bcfb0a827700"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5c88bd25-3fea-4b53-a5c3-29d534c2286e"}}}}, {"uuid": "eb63e254-b796-476a-afba-e8ebb47b74e4", "name": "cf5e3c94-b0f7-462e-a355-b258ae53f695_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4950137537296666, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.31506625700854357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "23da9e2b-d468-4008-b47f-d63d8c87dadb", "name": "6a1fe7ff-ccbd-46ac-b9ad-285f127c3344", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eb63e254-b796-476a-afba-e8ebb47b74e4"}}}]}, {"uuid": "2f75fc92-6b34-4785-8154-8f0b31b77142", "name": "load_p1rlv13796_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94ac9254-cdbf-4864-b22b-bcfb0a827700"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "23da9e2b-d468-4008-b47f-d63d8c87dadb"}}}}, {"uuid": "62825484-a85f-4497-9f3f-aa09f9016fe1", "name": "52fad3e9-45c9-4056-a73b-cb0e42e846c1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.008167500419157, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.871384812064858, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "40ad2075-2f27-43f9-bf26-24398179c740", "name": "15638478-3799-4f8d-a195-0cf7ad60607a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "62825484-a85f-4497-9f3f-aa09f9016fe1"}}}]}, {"uuid": "8e3b48bc-f743-4918-a2a8-d5c73997b5a5", "name": "load_p1rlv13801_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "accec892-a236-462d-b714-1178393ec992"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "40ad2075-2f27-43f9-bf26-24398179c740"}}}}, {"uuid": "da810e7f-f506-45e9-913d-f97a58abd11e", "name": "648f7673-2b7c-4917-9c63-f95e75196436_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.008167500419157, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.871384812064858, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1f8ea155-e6d1-4317-8ea6-a50f177cd91d", "name": "6e917f1f-4044-42e1-adfd-a0279c5d3d2d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "da810e7f-f506-45e9-913d-f97a58abd11e"}}}]}, {"uuid": "a0320d1d-20ae-462f-9746-521cd612a5bd", "name": "load_p1rlv13801_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "accec892-a236-462d-b714-1178393ec992"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1f8ea155-e6d1-4317-8ea6-a50f177cd91d"}}}}, {"uuid": "888affa1-c032-49bf-b439-d454732e868e", "name": "aa1d1c01-f032-40a4-85be-478812f1eec9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7055277650263714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24030088917661724, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f3390525-aa36-4b5e-b5c7-05b031722646", "name": "ac90927c-2c18-439c-9388-1849753638b9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "888affa1-c032-49bf-b439-d454732e868e"}}}]}, {"uuid": "0f26d234-dc12-4b26-9669-c0cc9f06d569", "name": "load_p1rlv13807_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c26fba44-3b81-47de-81e6-522f2daf0534"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f3390525-aa36-4b5e-b5c7-05b031722646"}}}}, {"uuid": "e816eb48-5381-4aa3-8477-15717e4343b5", "name": "3f3c2bee-1196-4b7f-aa9a-6b7f6163e03a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7055277650263714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24030088917661724, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "67b6d902-8b82-47cf-a989-f252d66071a4", "name": "4f177047-2b91-4fcc-aee1-b7321b7be182", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e816eb48-5381-4aa3-8477-15717e4343b5"}}}]}, {"uuid": "6d8a4cc7-ad2d-4b8e-9bdf-c6ca602aad0c", "name": "load_p1rlv13807_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c26fba44-3b81-47de-81e6-522f2daf0534"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "67b6d902-8b82-47cf-a989-f252d66071a4"}}}}, {"uuid": "d1cf8902-36ff-4259-8e06-9c26e6496790", "name": "4d637426-9411-4538-9c9c-90c7616f7121_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5041010955030301, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21577690333785765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4459f193-4f92-46a4-8eed-add2c2837094", "name": "95fb1d20-7bb6-49df-901a-9410ab8b79e9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d1cf8902-36ff-4259-8e06-9c26e6496790"}}}]}, {"uuid": "3e004b64-3af9-48f6-9dfd-fc8b13172d45", "name": "load_p1rlv13808_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c795ac7-3b49-4158-996d-2fb1f0337847"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4459f193-4f92-46a4-8eed-add2c2837094"}}}}, {"uuid": "2f4c2dc2-6bdb-4037-90cb-691a2702b98b", "name": "958bc998-f198-4634-9716-9c72eefb2a1c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5041010955030301, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21577690333785765, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "27270979-b92b-4d35-af3a-2c0e04df552b", "name": "0c08438e-daba-4da3-a5dc-db54fa184471", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2f4c2dc2-6bdb-4037-90cb-691a2702b98b"}}}]}, {"uuid": "74ab9452-4a60-4e6f-8072-464d74ee30df", "name": "load_p1rlv13808_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c795ac7-3b49-4158-996d-2fb1f0337847"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "27270979-b92b-4d35-af3a-2c0e04df552b"}}}}, {"uuid": "09eac509-8dac-41fe-9bce-64d8745425df", "name": "7dd53474-539f-4945-ac4c-c735c42112a5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0716753053645807, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8046017922971841, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "595de68a-b010-43ba-b21e-cc78f49bf48c", "name": "f02bea0f-dbc3-4422-a398-93888ea0def0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "09eac509-8dac-41fe-9bce-64d8745425df"}}}]}, {"uuid": "5c7db3cf-10d4-4267-8217-45a53afc7161", "name": "load_p1rlv13809_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "687996da-ab03-4544-b0d9-b79b8ac88e95"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "595de68a-b010-43ba-b21e-cc78f49bf48c"}}}}, {"uuid": "e5a9e2ec-ffef-4651-b51a-9f5316c82fb3", "name": "d7ece7d1-ce61-48ea-9df6-aa24014abecc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0716753053645807, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8046017922971841, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "efe80323-ab9b-4e01-815f-7fd0ce6c61df", "name": "92358e67-308f-4f32-b27a-e88559370266", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e5a9e2ec-ffef-4651-b51a-9f5316c82fb3"}}}]}, {"uuid": "0f2cf445-d144-43b5-80e0-38fd27f20829", "name": "load_p1rlv13809_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "687996da-ab03-4544-b0d9-b79b8ac88e95"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "efe80323-ab9b-4e01-815f-7fd0ce6c61df"}}}}, {"uuid": "764a156c-e82c-4978-9206-f52ce77f1f99", "name": "c1836a03-add8-4694-8d66-c2a6ed431151_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2437684685157903, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09956111056866535, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ae3347f6-7775-4433-814b-7ba9513e963e", "name": "bd38cf53-e217-4b92-a4c4-d1ffe15199df", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "764a156c-e82c-4978-9206-f52ce77f1f99"}}}]}, {"uuid": "55eed416-e9d9-4d58-8026-22b2f3f7cfe3", "name": "load_p1rlv13810_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab29ca66-d59b-4aa6-b5f6-165add0bc331"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ae3347f6-7775-4433-814b-7ba9513e963e"}}}}, {"uuid": "5cb79924-30c9-43e2-9a96-729fd0ac694c", "name": "3debea35-c388-41e2-83e2-aa90977b6cc3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2437684685157903, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09956111056866535, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2e0910b7-f02c-4d0e-bf15-f0b81921172f", "name": "f99681c6-3e7c-4c69-85c3-db72b795048f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5cb79924-30c9-43e2-9a96-729fd0ac694c"}}}]}, {"uuid": "8c2da7f0-f23d-49e5-a56f-820d68cb01a9", "name": "load_p1rlv13810_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab29ca66-d59b-4aa6-b5f6-165add0bc331"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2e0910b7-f02c-4d0e-bf15-f0b81921172f"}}}}, {"uuid": "8982f43c-2ab5-484c-91cd-8e23d4654b47", "name": "072f3713-115a-432e-b689-83fa9f6ad36d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.291842017688742, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7877197601951852, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0e13e8a7-69f7-4384-b6c2-6f9ab0821da4", "name": "a275ccd5-d06c-427c-b582-d3fa7d408111", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8982f43c-2ab5-484c-91cd-8e23d4654b47"}}}]}, {"uuid": "77fbe0a1-4002-4304-b6e3-b6284061bd2f", "name": "load_p1rlv13814_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028d5ead-7c34-400b-bcc1-c4d706c965d3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0e13e8a7-69f7-4384-b6c2-6f9ab0821da4"}}}}, {"uuid": "9c01f881-0f25-4d6f-a0dd-993098bd49f3", "name": "f2d86489-1f92-4a87-bfff-a752fdc6953b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.291842017688742, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7877197601951852, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d84a97b2-613d-4893-b775-76dcb6d72baf", "name": "beb70e77-2905-4532-b661-ae7947ab1dd9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9c01f881-0f25-4d6f-a0dd-993098bd49f3"}}}]}, {"uuid": "725fc8ff-fe31-4c43-a721-a77c74959288", "name": "load_p1rlv13814_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028d5ead-7c34-400b-bcc1-c4d706c965d3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d84a97b2-613d-4893-b775-76dcb6d72baf"}}}}, {"uuid": "9485e0ab-76b3-4249-95c6-c9694fbcc55f", "name": "186fb67b-61b4-4e51-85e1-ea65bdfd5178_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5478654763148745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5646840796232575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82a2547d-e285-4e42-9a0d-ba17743e95e5", "name": "c4052cf7-690b-460a-9695-67409665f911", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9485e0ab-76b3-4249-95c6-c9694fbcc55f"}}}]}, {"uuid": "61cacffc-8e4f-446d-9a8a-931f9727a422", "name": "load_p1rlv13815_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99957459-46a6-4b2b-9813-69b11ca7dad1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "82a2547d-e285-4e42-9a0d-ba17743e95e5"}}}}, {"uuid": "66b8279c-9e1c-45f4-b507-e46cf979f5c6", "name": "191437de-ee79-45c6-be63-1bbce4377cfc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5478654763148745, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5646840796232575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6ef4d2cf-ba8f-4ed5-8ce4-e3056b1156af", "name": "c7fff845-744f-4630-aa26-cd67a5961399", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "66b8279c-9e1c-45f4-b507-e46cf979f5c6"}}}]}, {"uuid": "76a08ec6-32a3-435c-9c52-2118ff199523", "name": "load_p1rlv13815_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99957459-46a6-4b2b-9813-69b11ca7dad1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6ef4d2cf-ba8f-4ed5-8ce4-e3056b1156af"}}}}, {"uuid": "a17c41d6-24e9-4b26-b9f9-de67964bb309", "name": "874e3fbd-6b4d-407a-8383-51ddc0d9aef7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0085854932437286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7150296414254909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "81850b27-a9b8-4fab-b10e-81a89ac0bc87", "name": "fc960aa0-6058-4889-b9e8-5a07b2878577", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a17c41d6-24e9-4b26-b9f9-de67964bb309"}}}]}, {"uuid": "f8444c20-8eea-40ac-a488-93a9711e5ff0", "name": "load_p1rlv13817_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e96bcc5b-07c5-4289-aec4-0224395c5e8a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "81850b27-a9b8-4fab-b10e-81a89ac0bc87"}}}}, {"uuid": "d54c2be7-a14b-4aef-8853-4acd41e72c47", "name": "3c0522c5-f6f6-4b47-a464-522778742137_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0085854932437286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7150296414254909, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "12e364e5-acfd-4e1d-89f6-21c9acd3d848", "name": "d620051e-a9a4-445e-aa26-8eca2cc48ec2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d54c2be7-a14b-4aef-8853-4acd41e72c47"}}}]}, {"uuid": "010ca500-2acf-4ce6-a039-674b272f9de8", "name": "load_p1rlv13817_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e96bcc5b-07c5-4289-aec4-0224395c5e8a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "12e364e5-acfd-4e1d-89f6-21c9acd3d848"}}}}, {"uuid": "4ed34c37-e2e9-4a65-a903-8a7caf11552c", "name": "78d7d066-06b1-4597-8e7d-fbf0e4036139_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1381537134701794, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42848704523913217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c0b7b5ac-4a0b-49c2-92c7-27cadd156772", "name": "aebf1b77-f7cf-43a9-a950-21464c55fb9e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4ed34c37-e2e9-4a65-a903-8a7caf11552c"}}}]}, {"uuid": "a8a6ea27-b4a4-4d06-8c4f-af8f1127daad", "name": "load_p1rlv13819_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36c12a74-a2ca-439a-a69f-308dd5cb1207"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c0b7b5ac-4a0b-49c2-92c7-27cadd156772"}}}}, {"uuid": "781fe3f1-6b6c-48b9-abd9-77d5b7369aae", "name": "5f1443a2-975b-4cb0-86c4-0b677d3a55db_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1381537134701794, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42848704523913217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "35ede9f1-60a6-4d8d-9701-723de6433418", "name": "efef0562-da88-4e42-aade-749922d559fa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "781fe3f1-6b6c-48b9-abd9-77d5b7369aae"}}}]}, {"uuid": "109422e2-02b7-4e4c-a09f-06afab81a341", "name": "load_p1rlv13819_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36c12a74-a2ca-439a-a69f-308dd5cb1207"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "35ede9f1-60a6-4d8d-9701-723de6433418"}}}}, {"uuid": "66d4d596-e4c7-4a54-a4e6-38df808f0693", "name": "14e258f3-02bd-4e24-95a2-41a1a66bfdb7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.3612796720379805, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.3972907909814523, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a31f4fb0-d83d-4ad1-86a9-4cfdf5a4bee9", "name": "9b2c0e73-1ff0-4035-bd34-92cd7d49c9be", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "66d4d596-e4c7-4a54-a4e6-38df808f0693"}}}]}, {"uuid": "85c9ad07-5dc3-47c3-aa58-1945480e5aff", "name": "load_p1rlv13820_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a2caa70b-9143-4676-834b-bfc7cb41330c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a31f4fb0-d83d-4ad1-86a9-4cfdf5a4bee9"}}}}, {"uuid": "b927f7b1-4142-4df3-a0fa-95a333a7982f", "name": "2a448f2a-f40c-4c5d-bd9f-5e1dc505e62d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.3612796720379805, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.3972907909814523, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bc7e8ec9-7648-41d1-8858-e4c8ddaaef33", "name": "98b412f3-26ab-4cfa-a65f-55021acba615", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b927f7b1-4142-4df3-a0fa-95a333a7982f"}}}]}, {"uuid": "d09ba371-5421-4487-90ee-5e8bfd642999", "name": "load_p1rlv13820_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a2caa70b-9143-4676-834b-bfc7cb41330c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bc7e8ec9-7648-41d1-8858-e4c8ddaaef33"}}}}, {"uuid": "ad98ac11-5d4c-4742-b631-47f8b8ad5445", "name": "ab8854ef-b22e-4714-8819-41beee60bb75_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.635130525488038, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.332876746135676, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a8dbac4e-81f6-40fa-8b95-8d36357946af", "name": "4d40fbdc-7093-474b-be43-a3bb70b4d5ff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ad98ac11-5d4c-4742-b631-47f8b8ad5445"}}}]}, {"uuid": "d501dc5e-ac3c-457d-9bc2-ea5a144144eb", "name": "load_p1rlv13821_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66e6c732-919a-4851-9f76-5580ea71669d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a8dbac4e-81f6-40fa-8b95-8d36357946af"}}}}, {"uuid": "8f0e7ca1-035f-45eb-b40d-b347ef767d4f", "name": "ca440c4c-f25c-4309-98c9-edf583c1ec98_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.635130525488038, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.332876746135676, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "57e80d64-eb9a-4869-acfa-665c994e1148", "name": "8ae6d28a-801a-45b2-8390-e0422e4f9124", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8f0e7ca1-035f-45eb-b40d-b347ef767d4f"}}}]}, {"uuid": "a78a4b78-fc95-4288-bc8f-85602712d6c7", "name": "load_p1rlv13821_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66e6c732-919a-4851-9f76-5580ea71669d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "57e80d64-eb9a-4869-acfa-665c994e1148"}}}}, {"uuid": "355253ea-407d-4eb0-9b8d-c609e3b8b8cc", "name": "6ebb2d5e-69fc-474d-bda3-d3b44a463d0c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7812856221781264, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.29493523962554685, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ff2e9217-8807-434d-a450-744efe345e72", "name": "3752c325-d5c2-4d40-8e38-7b04fc71177a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "355253ea-407d-4eb0-9b8d-c609e3b8b8cc"}}}]}, {"uuid": "68efcac0-34fe-4dd9-a0e2-fe0c3d757d94", "name": "load_p1rlv13822_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ade9991-a857-4619-8094-c18f824aaeb9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ff2e9217-8807-434d-a450-744efe345e72"}}}}, {"uuid": "6bd0f62f-8edf-4810-99be-e798cac24cf2", "name": "356dfa36-fd2a-4a57-8e5d-1a9549308602_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7812856221781264, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.29493523962554685, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6407febc-5c2c-4ba9-803c-40af9378c220", "name": "32c9cd48-906e-4915-b516-d48f6bb09d2c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6bd0f62f-8edf-4810-99be-e798cac24cf2"}}}]}, {"uuid": "4da4f5d5-66ee-4fcb-aea2-ce75b8f24a11", "name": "load_p1rlv13822_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ade9991-a857-4619-8094-c18f824aaeb9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6407febc-5c2c-4ba9-803c-40af9378c220"}}}}, {"uuid": "46b7186f-23aa-404f-89fe-b1da22b8988b", "name": "71a40a7d-0b07-4707-9fc8-7453aa248bbb_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1222862909492073, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34523553920221683, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c03ecb1d-7a8d-432a-87f1-649a7a2c0bd8", "name": "9143989a-51bb-4e7f-bbaf-2e6f00feef4c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "46b7186f-23aa-404f-89fe-b1da22b8988b"}}}]}, {"uuid": "b18c5017-b58a-4d8e-99df-186b1dba584a", "name": "load_p1rlv13823_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0ca6e47-afec-4d61-885a-e38176b32444"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c03ecb1d-7a8d-432a-87f1-649a7a2c0bd8"}}}}, {"uuid": "bc9b1700-bb49-4cb1-ba5d-5f80b5313fde", "name": "19de82c2-7a92-46ca-bc78-b9aa550e0efc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1222862909492073, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.34523553920221683, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "481ac917-3cd4-4104-bab6-aad3b2b02a90", "name": "1612e353-bc27-4924-95ca-d05df4a50023", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bc9b1700-bb49-4cb1-ba5d-5f80b5313fde"}}}]}, {"uuid": "96ad3f28-9350-4e7f-abbc-430e1bb63746", "name": "load_p1rlv13823_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0ca6e47-afec-4d61-885a-e38176b32444"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "481ac917-3cd4-4104-bab6-aad3b2b02a90"}}}}, {"uuid": "79f3753a-7149-4157-b5e4-68982efaa8ca", "name": "093cd540-9bbc-4ee5-a1e0-2e2ef4a34478_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0669054080609572, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7994840804155045, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f2b10606-cf40-4f5e-bb6b-1183f05e041e", "name": "acb548ef-de03-45bf-bf02-d36ee7faa744", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "79f3753a-7149-4157-b5e4-68982efaa8ca"}}}]}, {"uuid": "9c321716-f7ca-445e-b012-ab6f30c94193", "name": "load_p1rlv15585_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17bf6d8f-8215-4294-b921-cc3e34476f1e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f2b10606-cf40-4f5e-bb6b-1183f05e041e"}}}}, {"uuid": "e0082e7d-626d-4758-b35b-36b85a8bff3c", "name": "35e9eec9-3f85-4855-bfa4-52cf1d9cba4e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0669054080609572, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7994840804155045, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1edba1d9-3282-4395-a1ac-8fd917612c27", "name": "d0a1ea2f-1355-4c4d-878f-841f1e375af0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e0082e7d-626d-4758-b35b-36b85a8bff3c"}}}]}, {"uuid": "1cc5b71c-3d4d-4387-9b29-4375835ef133", "name": "load_p1rlv15585_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17bf6d8f-8215-4294-b921-cc3e34476f1e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1edba1d9-3282-4395-a1ac-8fd917612c27"}}}}, {"uuid": "54f40cb1-f555-4f22-9b86-3ed586a0c349", "name": "c29e80eb-35b5-42ba-9bbe-89cbf4d903da_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5604078463831266, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5882122505209306, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "059e1513-1fe8-44d2-9898-82d08b870b03", "name": "9b67a0dd-e06b-428b-bdf8-4ccfb9e0750b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "54f40cb1-f555-4f22-9b86-3ed586a0c349"}}}]}, {"uuid": "73b6699e-ca8b-43e4-b03e-082e1cc0e819", "name": "load_p1rlv15590_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef2a4478-4644-4bd3-9548-ab1d0be338b5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "059e1513-1fe8-44d2-9898-82d08b870b03"}}}}, {"uuid": "0e336d83-0a40-46ee-b0c8-a82812cf81a4", "name": "43ad8f4c-662d-4fb5-a5f9-a48dbaa271a7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5604078463831266, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5882122505209306, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2461bc70-0a3e-46b4-ad45-4297c1165017", "name": "4bf42159-d677-40ea-8cc5-b5591969ab5d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0e336d83-0a40-46ee-b0c8-a82812cf81a4"}}}]}, {"uuid": "7e04a4d6-9633-4b85-8c34-9d443e029fd6", "name": "load_p1rlv15590_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef2a4478-4644-4bd3-9548-ab1d0be338b5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2461bc70-0a3e-46b4-ad45-4297c1165017"}}}}, {"uuid": "f944fca3-773c-4d7f-8b9c-9c768d5194b2", "name": "9a7d04aa-5710-4fb1-bafb-40d7ed8d7695_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.478593979285423, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7308840963144931, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "17274469-c61a-4e5b-9160-1467f85cf8cf", "name": "931f85c8-2769-4c0e-9348-bb5827062179", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f944fca3-773c-4d7f-8b9c-9c768d5194b2"}}}]}, {"uuid": "a5d49acc-5c50-4480-842c-23e9d28d87bf", "name": "load_p1rlv15591_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c04c9ad1-4277-47de-9cec-9ce86e17b4f1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "17274469-c61a-4e5b-9160-1467f85cf8cf"}}}}, {"uuid": "0a49d7eb-c234-4ada-b568-908ac6cb8e4a", "name": "666b1c83-9b0c-4428-a813-b474316ec8f4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.478593979285423, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7308840963144931, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4148c82d-646b-4921-bc7a-6c5bf7f63ec7", "name": "c7b85c79-340b-4ef3-9ed6-191a807611d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0a49d7eb-c234-4ada-b568-908ac6cb8e4a"}}}]}, {"uuid": "ac304791-72f7-4e03-8c61-3aba5baa1c72", "name": "load_p1rlv15591_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c04c9ad1-4277-47de-9cec-9ce86e17b4f1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4148c82d-646b-4921-bc7a-6c5bf7f63ec7"}}}}, {"uuid": "d31de800-7b5e-4b79-8a91-b2ccf0116ef6", "name": "e1eb7567-068e-4f7f-9e16-f511bd93e9f6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.948793644259809, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2896354077041818, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2975b96e-edfa-4ad7-84f0-03367cdabd07", "name": "5e49d6ea-6260-48be-91dd-179c0bc5b5b4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d31de800-7b5e-4b79-8a91-b2ccf0116ef6"}}}]}, {"uuid": "3a9ac693-9be6-498c-ac0d-72e6efaca5cf", "name": "load_p1rlv15595_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "629e2259-2a59-4b20-b8bf-7b3b2c4a48f9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2975b96e-edfa-4ad7-84f0-03367cdabd07"}}}}, {"uuid": "ee77396d-e109-43f4-9c40-6bf91f21ab36", "name": "261e2ad9-5239-44cc-8678-56fd57346b98_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.948793644259809, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.2896354077041818, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eeb2ed11-f664-42aa-9324-d0f09b516145", "name": "b870489c-6cb3-4057-80e7-9cd9924ce7b2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ee77396d-e109-43f4-9c40-6bf91f21ab36"}}}]}, {"uuid": "176c85cb-d0d6-4c48-b671-648e88751c24", "name": "load_p1rlv15595_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "629e2259-2a59-4b20-b8bf-7b3b2c4a48f9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eeb2ed11-f664-42aa-9324-d0f09b516145"}}}}, {"uuid": "a0cb21e7-4b27-494e-bb3c-081400c00bc8", "name": "7667dd6b-9cfc-4f76-a0e9-130988b27064_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6211116916449642, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3778136238343289, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "71b9d2b3-acfd-4691-9f5f-adf773dd27d8", "name": "f26b0db5-6978-4f0a-a69e-fc122b3225bb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a0cb21e7-4b27-494e-bb3c-081400c00bc8"}}}]}, {"uuid": "bf2cc4c4-abae-4bad-9ca5-5ea2c5f8bbfc", "name": "load_p1rlv15598_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "af6b7d1b-896f-44ac-8038-748c74507253"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "71b9d2b3-acfd-4691-9f5f-adf773dd27d8"}}}}, {"uuid": "81dfd6e0-dbbb-41cf-81aa-9fb817150959", "name": "8b6a8b1c-53fd-4091-9649-2bfb2059685f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6211116916449642, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3778136238343289, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "10db06a2-89ef-4e34-9cbb-f016a6dc8746", "name": "60ca488e-a6f0-43aa-9158-5c4134a82e18", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "81dfd6e0-dbbb-41cf-81aa-9fb817150959"}}}]}, {"uuid": "ab44ad34-bc95-4072-8e13-b0f8a2f34e93", "name": "load_p1rlv15598_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "af6b7d1b-896f-44ac-8038-748c74507253"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "10db06a2-89ef-4e34-9cbb-f016a6dc8746"}}}}, {"uuid": "de0aecc7-b36d-4357-a63e-d9785ef9bd9e", "name": "e8956775-6849-4664-a683-f47391afb338_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6626119076444468, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.30654437548368263, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "be09f5f7-fed8-43b1-b26d-c8aec95e842a", "name": "84b3e339-af7c-41c6-b51d-3c1a69a7ecf2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "de0aecc7-b36d-4357-a63e-d9785ef9bd9e"}}}]}, {"uuid": "62789cd6-098e-4f7b-8814-72c8eb1034f7", "name": "load_p1rlv15599_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ae1bbf1-459f-4346-b525-393b7d1dc958"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "be09f5f7-fed8-43b1-b26d-c8aec95e842a"}}}}, {"uuid": "8f1f6184-fcb4-4f3a-8e3f-f9f39682703d", "name": "a0dec14d-ea6f-4bfe-8b30-760d5443cf0a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6626119076444468, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.30654437548368263, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "01885877-0367-499f-83f1-52c8a24fec2e", "name": "ebec3fea-a57f-42a2-ab97-b2a72764c4a9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8f1f6184-fcb4-4f3a-8e3f-f9f39682703d"}}}]}, {"uuid": "ee2fb437-7c18-43e0-a778-72bbb4ecaf9d", "name": "load_p1rlv15599_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ae1bbf1-459f-4346-b525-393b7d1dc958"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "01885877-0367-499f-83f1-52c8a24fec2e"}}}}, {"uuid": "e56b29a0-5f6f-4023-90d3-cfe2d5ef010b", "name": "168abaa0-2fb2-4799-a684-581c86f41a4f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5348201699646123, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21241824123648728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b5869fd3-257a-473f-b5d2-282d0b26d37c", "name": "40231832-f936-4a1e-8d34-f03562bbd8aa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e56b29a0-5f6f-4023-90d3-cfe2d5ef010b"}}}]}, {"uuid": "5c5f9ae0-221c-48b9-86c2-5f669de204a3", "name": "load_p1rlv15604_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95b45d46-b7e7-46e2-98d9-5034e2fa0a17"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b5869fd3-257a-473f-b5d2-282d0b26d37c"}}}}, {"uuid": "87de1d2f-cb99-4681-b480-a5253cd1986a", "name": "0ee55c44-0e48-4ead-8915-bd8a7ece68c4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5348201699646123, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.21241824123648728, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "524946ab-d09d-4447-8882-4767d74df004", "name": "a25383b2-0b5e-4385-a110-4074e5c8c5b4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "87de1d2f-cb99-4681-b480-a5253cd1986a"}}}]}, {"uuid": "3fee4c6e-4a64-4574-bd57-4bfcba0420d2", "name": "load_p1rlv15604_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95b45d46-b7e7-46e2-98d9-5034e2fa0a17"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "524946ab-d09d-4447-8882-4767d74df004"}}}}, {"uuid": "662ce46f-3407-471f-a2d1-7adef310daae", "name": "b17569db-16f1-46a4-82ef-66575d501701_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7411160800233395, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1601349573814363, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bfcb1024-72a9-490c-8f55-ccb820aca246", "name": "0d318d79-dcc9-40fd-a6ea-08c8a1ae04be", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "662ce46f-3407-471f-a2d1-7adef310daae"}}}]}, {"uuid": "cb8b01f1-db5f-4676-8d79-e4ccbf10fae9", "name": "load_p1rlv15605_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcbee2ff-bf73-4834-bc3c-46fa0cfcad7c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bfcb1024-72a9-490c-8f55-ccb820aca246"}}}}, {"uuid": "205aab40-1007-48e6-83a7-4510a1f97591", "name": "8175f2e1-ebdb-424a-a3c2-2caf2256e5fc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7411160800233395, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1601349573814363, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1dedfe32-2b65-4f1a-a054-b0de2a8836b9", "name": "1a392444-0d33-46c5-8e8d-cbd0f3964e7c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "205aab40-1007-48e6-83a7-4510a1f97591"}}}]}, {"uuid": "3864a69d-0240-4a2a-83cd-4d7e71841b86", "name": "load_p1rlv15605_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcbee2ff-bf73-4834-bc3c-46fa0cfcad7c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1dedfe32-2b65-4f1a-a054-b0de2a8836b9"}}}}, {"uuid": "828cc09a-fe2a-4ee1-9a72-a9b480f38b6e", "name": "fa3d92fd-97ad-40ff-9d8f-f84c88373f5c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1813646779377422, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20173832232537287, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fc35cab6-95e9-44c5-b70f-05b92b4d412d", "name": "fc0295ec-7b0d-4e55-bd2d-8d88ed0eabb7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "828cc09a-fe2a-4ee1-9a72-a9b480f38b6e"}}}]}, {"uuid": "f3c39724-bce3-49eb-a332-5055b6ee129b", "name": "load_p1rlv15608_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13d6bce6-9066-43a1-b2b6-00a2a4398958"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fc35cab6-95e9-44c5-b70f-05b92b4d412d"}}}}, {"uuid": "c83a74b2-d475-4147-808e-0dccf1a9a3b4", "name": "3d38d38b-5d2d-4970-b5e3-886dde0671c1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1813646779377422, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.20173832232537287, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "002ae075-c151-4cc2-9fb9-85a86472f2f9", "name": "a87fb5a0-40b5-4eee-b194-d1f698ed5f37", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c83a74b2-d475-4147-808e-0dccf1a9a3b4"}}}]}, {"uuid": "9055524e-3ac0-4565-b9cd-93f4591fcec6", "name": "load_p1rlv15608_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13d6bce6-9066-43a1-b2b6-00a2a4398958"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "002ae075-c151-4cc2-9fb9-85a86472f2f9"}}}}, {"uuid": "4212ded5-f581-4764-a59d-65fa5f2a198c", "name": "5d907014-cc5a-402a-8bf4-c18f781cafa2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.046232297850773, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7285366000251032, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "46d7587a-7dad-42d6-b692-57ee52c08570", "name": "443cdf73-68ba-4425-9e0d-2be0e1cf4df1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4212ded5-f581-4764-a59d-65fa5f2a198c"}}}]}, {"uuid": "e5249452-bd5d-4408-aa97-f2be5b14b2f0", "name": "load_p1rlv15616_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43ed408e-35e2-4bca-9060-a0c211aea1e7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "46d7587a-7dad-42d6-b692-57ee52c08570"}}}}, {"uuid": "0384f4b8-3dd0-4a01-b3f9-5c3a03a67deb", "name": "82d07e53-05b9-4605-8c73-35c475f1fa40_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.046232297850773, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7285366000251032, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "acb2dbdb-58a4-4de6-9fc8-e8efcb0a1324", "name": "a2877474-25d5-4c42-a694-63c46491a769", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0384f4b8-3dd0-4a01-b3f9-5c3a03a67deb"}}}]}, {"uuid": "a44343d7-5bcb-4693-96f3-3ad2aa61a044", "name": "load_p1rlv15616_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43ed408e-35e2-4bca-9060-a0c211aea1e7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "acb2dbdb-58a4-4de6-9fc8-e8efcb0a1324"}}}}, {"uuid": "eabfde0e-54b8-44df-bd7e-aea1271f9ace", "name": "0f43caab-2a22-4b0f-8055-033e5a86d4da_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2795803428770153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1698974287191981, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f9eb67dd-74bc-4c46-831e-e02d1fb1d898", "name": "88e50214-eb50-4621-b000-3d73ab001257", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "eabfde0e-54b8-44df-bd7e-aea1271f9ace"}}}]}, {"uuid": "dea108c1-e877-4a90-8f38-feaf33fb1e3b", "name": "load_p1rlv15618_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "200aa7d8-0a43-4086-b0e7-f63cae75671d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f9eb67dd-74bc-4c46-831e-e02d1fb1d898"}}}}, {"uuid": "72e1553d-91d7-47c0-a4eb-4e5b1bb3bed1", "name": "80570795-9843-475c-9431-752d767622cc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.2795803428770153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1698974287191981, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9519faae-cb8f-4544-8ea7-cb5f9a681c54", "name": "d14c1fab-bf8a-42c8-8b83-33d7dd168bf8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72e1553d-91d7-47c0-a4eb-4e5b1bb3bed1"}}}]}, {"uuid": "9e1f6c2e-94d7-4757-b33b-82228d4eabd2", "name": "load_p1rlv15618_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "200aa7d8-0a43-4086-b0e7-f63cae75671d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9519faae-cb8f-4544-8ea7-cb5f9a681c54"}}}}, {"uuid": "b092f45d-9015-4c29-a4a7-b76faa9b58f0", "name": "9c39cbd7-0fe5-4467-a773-210bfae39bd0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8454259827639654, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5306926284494342, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "065a8765-34d9-4f06-9611-d4f0c1216795", "name": "a23ad787-c2d5-496e-925e-33372bfc20a6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b092f45d-9015-4c29-a4a7-b76faa9b58f0"}}}]}, {"uuid": "f762ccda-562f-486a-9c52-40097d41b4da", "name": "load_p1rlv15619_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905a4857-5d3d-4e51-9ab0-70d634170f92"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "065a8765-34d9-4f06-9611-d4f0c1216795"}}}}, {"uuid": "e4498d19-aa92-4345-a2ac-ff62048aeb4c", "name": "fbbad8a2-7d6a-4e4d-b380-17af10ae674a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8454259827639654, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5306926284494342, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d223123b-5936-4b5f-8033-2e9c6b2c90fb", "name": "3dc826b0-e993-46b2-acdb-f78e8576f816", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e4498d19-aa92-4345-a2ac-ff62048aeb4c"}}}]}, {"uuid": "d30393bc-6418-416e-83ac-29f25e4da89f", "name": "load_p1rlv15619_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905a4857-5d3d-4e51-9ab0-70d634170f92"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d223123b-5936-4b5f-8033-2e9c6b2c90fb"}}}}, {"uuid": "3ea87847-071d-451f-bd19-6d82c1ce111f", "name": "aa9ec67c-7807-4a16-acdf-62bc65f7fa19_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5924067901709626, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.46681640832512994, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "08427ead-ad00-4a10-a10d-e7d4da17a254", "name": "a2e361e0-b106-43a0-906c-35a429e96aea", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3ea87847-071d-451f-bd19-6d82c1ce111f"}}}]}, {"uuid": "1904ede3-a1c8-4565-adc7-d679845b0c95", "name": "load_p1rlv15623_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13f790a1-18c0-498f-8525-fbaf0350947b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "08427ead-ad00-4a10-a10d-e7d4da17a254"}}}}, {"uuid": "4f3fa56d-4b8b-47bc-8a88-d4518112bfbb", "name": "49271121-f195-4dc2-9617-3e41417e9f63_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5924067901709626, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.46681640832512994, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ddfbadbd-d94a-463c-b3fa-a1586a9f8ff3", "name": "e9f05cd5-7af3-4225-81e8-0d9267e8fa64", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4f3fa56d-4b8b-47bc-8a88-d4518112bfbb"}}}]}, {"uuid": "95a7b4d1-8c53-42fd-8fe4-74537a2ee45a", "name": "load_p1rlv15623_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13f790a1-18c0-498f-8525-fbaf0350947b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ddfbadbd-d94a-463c-b3fa-a1586a9f8ff3"}}}}, {"uuid": "1d62a7aa-8b10-44bd-ace9-bf5f8061dd23", "name": "f3ee2678-10a3-407d-a28b-1259924b2b44_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6658189308849048, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3864031015392916, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ee3e309b-bd35-40cd-b2b0-6498a1ff6210", "name": "df422b58-6f34-4522-86e9-cd47c632de13", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1d62a7aa-8b10-44bd-ace9-bf5f8061dd23"}}}]}, {"uuid": "fa99cc7b-2e73-4524-b411-78eacbc75990", "name": "load_p1rlv15625_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb08eda2-b277-4bfd-9ea0-9c36765400bd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ee3e309b-bd35-40cd-b2b0-6498a1ff6210"}}}}, {"uuid": "2a5215a6-8da4-4afa-a0b7-3cef1822b4ef", "name": "8877d052-007c-40eb-a879-4f58aa9e7211_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6658189308849048, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3864031015392916, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b6bfe314-6117-4811-b014-92996f13c84f", "name": "6fa26fb9-a44a-4269-84ab-a6b6259ca31f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2a5215a6-8da4-4afa-a0b7-3cef1822b4ef"}}}]}, {"uuid": "87950dc1-c23f-454f-845e-94f5fbb13603", "name": "load_p1rlv15625_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb08eda2-b277-4bfd-9ea0-9c36765400bd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b6bfe314-6117-4811-b014-92996f13c84f"}}}}, {"uuid": "be3ca802-c7d2-47de-972d-322cd93807e5", "name": "a17e6c75-25ef-446e-861a-3263eef75cc6_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3315344999322854, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13574204648198762, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "93b4ac9f-fd66-4459-b9b2-a60a7625fdd6", "name": "1b46f718-4f26-4402-a080-7744de60b05b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "be3ca802-c7d2-47de-972d-322cd93807e5"}}}]}, {"uuid": "ad0a8ed6-24d4-4e8f-ac53-88c9b689021e", "name": "load_p1rlv15632_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ccbef4c-6bf7-4892-a3b9-b51aca495137"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "93b4ac9f-fd66-4459-b9b2-a60a7625fdd6"}}}}, {"uuid": "c810fca3-d772-4a8f-9082-c6e72ac4e6db", "name": "6d0f8720-ca97-4483-85b1-fcfbc3d9a247_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.3315344999322854, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.13574204648198762, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eb7dc31a-acec-41e8-9d07-1c90bf9490b1", "name": "d7af0015-c346-4b4e-a53e-6fa094559f64", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c810fca3-d772-4a8f-9082-c6e72ac4e6db"}}}]}, {"uuid": "b326beb8-6531-4490-84c5-a9014d18cd2f", "name": "load_p1rlv15632_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ccbef4c-6bf7-4892-a3b9-b51aca495137"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eb7dc31a-acec-41e8-9d07-1c90bf9490b1"}}}}, {"uuid": "9e89186f-82c8-41ae-9f16-c28e00c70659", "name": "d62a87d2-b3fd-4ff1-a057-d63355bf6822_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4063851199490187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16385595528128288, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "bbc4101b-7e69-4f71-ae4f-53856d686d1e", "name": "2c8f31ec-0268-4a3f-801f-a40f82c15c62", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9e89186f-82c8-41ae-9f16-c28e00c70659"}}}]}, {"uuid": "375a5e05-3568-4779-b978-37d6522d61fb", "name": "load_p1rlv15633_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce7b60c8-43ee-441d-9f18-5b2722dcc0a7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "bbc4101b-7e69-4f71-ae4f-53856d686d1e"}}}}, {"uuid": "9f5b58b3-7848-4775-845e-a70f87019061", "name": "35b90394-c4d5-42e8-b3ed-6a734fc56860_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.4063851199490187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.16385595528128288, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f85b18e2-a935-4f00-bcc3-eb8850675b5f", "name": "d22eb452-a604-4f20-9803-82933df8d181", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9f5b58b3-7848-4775-845e-a70f87019061"}}}]}, {"uuid": "fd01f3fc-80cc-451d-ba6b-6cdba33c7311", "name": "load_p1rlv15633_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce7b60c8-43ee-441d-9f18-5b2722dcc0a7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f85b18e2-a935-4f00-bcc3-eb8850675b5f"}}}}, {"uuid": "2300e2b1-e466-437d-af39-12dc106ea0f1", "name": "7083a3fa-3140-4ecb-8a87-8c51ca8cac19_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.416529851525178, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1922168413006689, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7b14e0f6-ca0f-4794-8615-bd6fd05cc72d", "name": "ec7fc012-219d-49fd-a2f2-21417ffd3ed0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2300e2b1-e466-437d-af39-12dc106ea0f1"}}}]}, {"uuid": "cc963929-deac-4c2d-93ca-eec6f3895b48", "name": "load_p1rlv15640_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83c2de51-1b04-483c-8ce7-14b9e5e027b9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7b14e0f6-ca0f-4794-8615-bd6fd05cc72d"}}}}, {"uuid": "c18fc0b9-d5ea-4253-b272-6a950aa0a4a2", "name": "20882bd3-8746-4413-a346-e24319680df6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.416529851525178, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1922168413006689, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "73414de7-7f37-44cd-a4ca-74716bb26fa2", "name": "106eb0d3-138e-4640-8725-abd2ec7b195f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c18fc0b9-d5ea-4253-b272-6a950aa0a4a2"}}}]}, {"uuid": "8de61cc1-a633-4ef4-ad8d-12c1c479f199", "name": "load_p1rlv15640_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83c2de51-1b04-483c-8ce7-14b9e5e027b9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "73414de7-7f37-44cd-a4ca-74716bb26fa2"}}}}, {"uuid": "27831177-8035-4f9b-b8ff-9d9ea31439af", "name": "69f11f40-bb60-4012-8526-4aad1d2aa1ab_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7538406343539102, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42176934505781605, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4e2d6287-dbf6-47f8-b6f0-bf31d11f7660", "name": "9556de5c-ea12-4b65-ba76-b3e4676b8b38", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "27831177-8035-4f9b-b8ff-9d9ea31439af"}}}]}, {"uuid": "0b6ca4e4-706a-4f46-abf0-c6bc68a0ddac", "name": "load_p1rlv15641_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4363602a-eb9c-41b8-8130-7bb839f4eb5a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4e2d6287-dbf6-47f8-b6f0-bf31d11f7660"}}}}, {"uuid": "873fe6a2-2e17-4658-b8f6-1a976d9d758f", "name": "8823a533-2fa9-4c9d-b797-0df5529291c2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7538406343539102, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.42176934505781605, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "de902fe0-2d32-42b3-a757-0dba337785ad", "name": "89d360e4-e1c1-43c5-bad9-2f3f7ea7c261", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "873fe6a2-2e17-4658-b8f6-1a976d9d758f"}}}]}, {"uuid": "434acaad-5c0d-49d4-a568-2850f9fd6300", "name": "load_p1rlv15641_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4363602a-eb9c-41b8-8130-7bb839f4eb5a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "de902fe0-2d32-42b3-a757-0dba337785ad"}}}}, {"uuid": "b5d548f7-c235-4f56-a5e8-73b437dfec64", "name": "2dcf3af2-8b6d-4f62-ace6-d8e121983252_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.735884899619907, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7862059386133167, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ea218f6e-dfd3-438b-adcf-852aa343204b", "name": "28b3c749-4582-4f26-9e07-d9887cd70465", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b5d548f7-c235-4f56-a5e8-73b437dfec64"}}}]}, {"uuid": "31e35185-7faa-4548-a082-94b778d715eb", "name": "load_p1rlv16450_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5f1e7aa-d93a-4164-8bc0-f920259304a8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ea218f6e-dfd3-438b-adcf-852aa343204b"}}}}, {"uuid": "92762c3b-686c-4ce0-9e31-45def15ff6d2", "name": "82753a5d-5757-46fd-b47b-63058b1199e2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.735884899619907, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7862059386133167, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5a3f23f0-a34b-4071-93c5-5d8151415cd1", "name": "8e27ec17-be51-429a-8af7-638943f57ef9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "92762c3b-686c-4ce0-9e31-45def15ff6d2"}}}]}, {"uuid": "6dd3a333-b113-4ad1-9cfc-2ee8193aa02c", "name": "load_p1rlv16450_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5f1e7aa-d93a-4164-8bc0-f920259304a8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5a3f23f0-a34b-4071-93c5-5d8151415cd1"}}}}, {"uuid": "d18f355d-432d-4a81-9f79-60ce72b17264", "name": "cb98fa40-de8c-4a97-bb6c-3b878a09ab9c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5229589832640044, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3359880712066463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7ce996db-a06e-43c8-b644-32f3f75d9413", "name": "8e4e1985-8cc9-45fc-8143-fc433d8de810", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d18f355d-432d-4a81-9f79-60ce72b17264"}}}]}, {"uuid": "9fb0240a-337c-448b-9787-66aea3750bf3", "name": "load_p1rlv16463_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9c505d7-3fb9-4eb5-89c6-c9c8da32fd05"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7ce996db-a06e-43c8-b644-32f3f75d9413"}}}}, {"uuid": "3e585105-6eb1-4266-852c-d96bef3e20ae", "name": "9ac799f5-91b0-4380-a5f3-e07f877df701_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5229589832640044, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3359880712066463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8c691fc0-826c-469b-8458-924b9d4bb2a5", "name": "8bbcadb3-5213-4a50-8ee5-177fdb53534a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3e585105-6eb1-4266-852c-d96bef3e20ae"}}}]}, {"uuid": "22237d0f-60d8-42bf-a53a-99468f18ea7d", "name": "load_p1rlv16463_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9c505d7-3fb9-4eb5-89c6-c9c8da32fd05"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8c691fc0-826c-469b-8458-924b9d4bb2a5"}}}}, {"uuid": "72f9e304-6f77-4048-b244-b47d987386d5", "name": "4354d6de-b840-4a59-921c-48546a5918ba_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.868352089343376, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.8531787232937273, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "93240c18-7579-465b-b310-1d14ad8e8dd2", "name": "1b380adb-20db-4447-a4b5-36eb7224e1cd", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72f9e304-6f77-4048-b244-b47d987386d5"}}}]}, {"uuid": "abdb5a0e-b49e-4045-8a50-c71f708e8057", "name": "load_p1rlv16475_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d400b1b2-8404-4b80-b110-6f96e000314f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "93240c18-7579-465b-b310-1d14ad8e8dd2"}}}}, {"uuid": "888d1efa-55da-4fa0-8fdb-34cd43bddd9c", "name": "a7c7a516-35b1-4b3f-879d-b052684964fa_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.868352089343376, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.8531787232937273, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "de871ffd-f009-4ca8-a997-be1e4f88ae66", "name": "28e02cf2-5047-48fa-b542-ae2aa753401c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "888d1efa-55da-4fa0-8fdb-34cd43bddd9c"}}}]}, {"uuid": "7022f268-f6f5-4642-84f1-7377872a39a4", "name": "load_p1rlv16475_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d400b1b2-8404-4b80-b110-6f96e000314f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "de871ffd-f009-4ca8-a997-be1e4f88ae66"}}}}, {"uuid": "e54ec48a-9076-420f-9ddf-0ab004897c81", "name": "ad316ba8-bdcf-4aee-9cab-506969847b73_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8816313976351899, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.38647586315113985, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b570d166-7b24-49d5-88c7-3c2de440b7aa", "name": "46e26fb5-cd03-4009-bee3-b4653939f1ce", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e54ec48a-9076-420f-9ddf-0ab004897c81"}}}]}, {"uuid": "8dc71af4-8b75-4782-aebf-fbdb147c277f", "name": "load_p1rlv16483_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa6db7ee-126d-4aa9-9733-35ff1c1d5992"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b570d166-7b24-49d5-88c7-3c2de440b7aa"}}}}, {"uuid": "7c2bbc90-c373-4787-802b-91686bbd16d5", "name": "090e10fe-03aa-46ba-94f3-4af619297bc0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8816313976351899, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.38647586315113985, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "74fecb5e-7b8c-4aad-8bf6-f551ad043802", "name": "e5f549bd-698c-4aeb-a297-e7da4d5ac566", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7c2bbc90-c373-4787-802b-91686bbd16d5"}}}]}, {"uuid": "4efd8407-afeb-45a9-a658-989c9fd49d4c", "name": "load_p1rlv16483_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa6db7ee-126d-4aa9-9733-35ff1c1d5992"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "74fecb5e-7b8c-4aad-8bf6-f551ad043802"}}}}, {"uuid": "6a389484-bc0c-4d4a-9d31-54a1bac5a030", "name": "517e95b3-d4e7-426f-a862-33d7532e6650_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8285317723273034, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9836303634928509, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50c5124f-e767-48e1-8fa3-c1f23dc1d946", "name": "a0ff77a5-a9f2-47c3-a9f0-0e6549119ed2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6a389484-bc0c-4d4a-9d31-54a1bac5a030"}}}]}, {"uuid": "f0aac045-0e01-4455-a8d7-50f8a24b39c3", "name": "load_p1rlv16507_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27afe70a-9123-4b0c-9f50-b5355aafcf7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50c5124f-e767-48e1-8fa3-c1f23dc1d946"}}}}, {"uuid": "c1f72a93-2c6d-40f0-9e88-066edd0bc299", "name": "2473520e-3c51-4226-8681-2bf2d8f864ed_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.8285317723273034, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9836303634928509, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "46e400db-45a5-4016-81f6-e5e8c50fe0cf", "name": "ae99d7bd-fb17-4727-8fa6-b70d61ae23d5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c1f72a93-2c6d-40f0-9e88-066edd0bc299"}}}]}, {"uuid": "f9802863-0ac4-4648-9bc4-1868376b0046", "name": "load_p1rlv16507_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27afe70a-9123-4b0c-9f50-b5355aafcf7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "46e400db-45a5-4016-81f6-e5e8c50fe0cf"}}}}, {"uuid": "f3ad0ef9-ac5b-424c-8d55-c35e3ec43d71", "name": "5d16bf4b-825c-48d8-a9f2-9591f938775a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6976007564693765, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0012223642000246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ffe7b4e6-144c-462e-b003-deb4036a99ea", "name": "3d434c4a-07a6-4e66-ac93-41189685d682", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f3ad0ef9-ac5b-424c-8d55-c35e3ec43d71"}}}]}, {"uuid": "fd615f28-bdaf-4b10-9f8b-29ce22898ce0", "name": "load_p1rlv16530_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0333a34b-4027-4d9a-9d4a-f867c8a317bc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ffe7b4e6-144c-462e-b003-deb4036a99ea"}}}}, {"uuid": "00566696-d4c5-4a31-a3ea-5c779c66ed5f", "name": "a348b52e-9808-4ede-8bdb-17768e1e41f4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6976007564693765, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0012223642000246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c715d386-cc2d-42e8-89f5-4da411227d56", "name": "e6ec601a-04c7-431c-883b-c60ba0d73b21", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "00566696-d4c5-4a31-a3ea-5c779c66ed5f"}}}]}, {"uuid": "5b4755a8-7f30-4e67-99cc-615124fa8969", "name": "load_p1rlv16530_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0333a34b-4027-4d9a-9d4a-f867c8a317bc"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c715d386-cc2d-42e8-89f5-4da411227d56"}}}}, {"uuid": "7c3feb6e-7699-4b8b-bf81-a1303d4ac613", "name": "b00d351f-caff-4efb-8285-802db0138ef5_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4622944887503224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10483650830237357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4aae7ad0-4668-4e2e-b349-05395e064136", "name": "c6792b81-42b7-4e82-b405-1329e781b3c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7c3feb6e-7699-4b8b-bf81-a1303d4ac613"}}}]}, {"uuid": "a6fd724d-b412-4387-baec-28ba0a8ae5c1", "name": "load_p1rlv16541_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f7be042-6681-4694-872d-a1cb701016c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4aae7ad0-4668-4e2e-b349-05395e064136"}}}}, {"uuid": "d789f394-4e99-4645-94a6-dd32d419c082", "name": "b66e098d-d15f-4275-b427-18e96faa709b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4622944887503224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.10483650830237357, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6377f5e3-4e07-4044-bdd0-6e24cf13cf0b", "name": "1276e012-d2e9-4117-a1a2-3d977832a75a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d789f394-4e99-4645-94a6-dd32d419c082"}}}]}, {"uuid": "87a3f4ec-41e0-4b20-ab89-7fb590e660c7", "name": "load_p1rlv16541_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f7be042-6681-4694-872d-a1cb701016c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6377f5e3-4e07-4044-bdd0-6e24cf13cf0b"}}}}, {"uuid": "6c69e703-71cd-486d-ad05-17837f07fddc", "name": "2ced9ebc-d211-443f-9e72-af7d95d3849a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.962510599658346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.39927803268124257, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3e01c7b8-27b5-4ec3-8f06-3389efbecb65", "name": "9af5c881-7e46-4b5e-a998-959c23794c2e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c69e703-71cd-486d-ad05-17837f07fddc"}}}]}, {"uuid": "94d30e7c-66e1-41e1-9fd0-101444495776", "name": "load_p1rlv16573_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90d9dbe9-f9c9-4a4e-8ada-cb459778687b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3e01c7b8-27b5-4ec3-8f06-3389efbecb65"}}}}, {"uuid": "676745fc-79d7-458c-9e05-6e092caa2b3f", "name": "1a1a8e15-1ec4-4929-97f2-cc5316e1bc83_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.962510599658346, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.39927803268124257, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0e2c3022-4cb6-446b-ae2c-3428b4af05af", "name": "336a777f-09ce-4bf3-b11a-3cbe06f7619d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "676745fc-79d7-458c-9e05-6e092caa2b3f"}}}]}, {"uuid": "1b19dde5-8cdf-4897-a926-2c48ebc763a9", "name": "load_p1rlv16573_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90d9dbe9-f9c9-4a4e-8ada-cb459778687b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0e2c3022-4cb6-446b-ae2c-3428b4af05af"}}}}, {"uuid": "17418aba-721c-4315-94ab-f8def94d1c19", "name": "fce4c617-6785-4a22-b6a1-ff8dec801232_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6976007564693765, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0012223642000246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ddd490af-260d-46e4-8ca9-b21cc6bc2d46", "name": "f35dc42e-9781-4443-84df-4a624454cc9f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "17418aba-721c-4315-94ab-f8def94d1c19"}}}]}, {"uuid": "397456e3-3cb5-470b-be37-3e79d3c899ed", "name": "load_p1rlv16584_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "344c6b21-94c9-4912-a19e-69fbae5eed27"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ddd490af-260d-46e4-8ca9-b21cc6bc2d46"}}}}, {"uuid": "f6211fd3-d0ef-414f-8de3-78c78457a87b", "name": "6aa9bc57-2165-459d-b3a6-36c43fcac88b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.6976007564693765, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0012223642000246, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2a865d4a-7f45-47ee-92b3-1f9e5a08b46e", "name": "81959ead-a5ed-4ab3-b74d-0ab0b5855cbe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f6211fd3-d0ef-414f-8de3-78c78457a87b"}}}]}, {"uuid": "b535f7e2-9aa2-4481-8507-d774c5c8dd99", "name": "load_p1rlv16584_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "344c6b21-94c9-4912-a19e-69fbae5eed27"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2a865d4a-7f45-47ee-92b3-1f9e5a08b46e"}}}}, {"uuid": "7648cf74-49da-4631-b023-8a26cdff5a97", "name": "db32424a-4750-4cf6-8cb1-bca90476f529_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4820522770729507, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1125677048872814, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "80554816-b458-45b0-8147-a0037851a770", "name": "7166e439-29ab-4ca8-97ad-b062ea3cdbf4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7648cf74-49da-4631-b023-8a26cdff5a97"}}}]}, {"uuid": "4e358a7e-2f97-47f3-b250-04a30db6372c", "name": "load_p1rlv16604_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f9ecb3f-8b64-4598-a9d1-d794c6800d33"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "80554816-b458-45b0-8147-a0037851a770"}}}}, {"uuid": "d64daa14-f7d7-453a-b0a2-b461372c8200", "name": "8a74909b-00b5-4d43-a62c-e396702c1c31_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4820522770729507, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1125677048872814, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "888cb114-7f8f-4d27-b18c-9a8bdf45a92e", "name": "2ac3ef4a-cebc-4d3c-a28c-3690ee0ba266", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d64daa14-f7d7-453a-b0a2-b461372c8200"}}}]}, {"uuid": "e0a235d2-9c25-45cd-a2c3-f08de8da1c81", "name": "load_p1rlv16604_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f9ecb3f-8b64-4598-a9d1-d794c6800d33"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "888cb114-7f8f-4d27-b18c-9a8bdf45a92e"}}}}, {"uuid": "6b32ecbb-ef6d-492e-8dcb-52e75307d744", "name": "ad0f3347-eb7f-4599-800f-4b0b8801488a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8791002615066037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24190904367644575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "050f8a43-86e9-440e-9013-a602a5347d35", "name": "a22947a6-bcbc-4935-aba8-86f0843db3d7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6b32ecbb-ef6d-492e-8dcb-52e75307d744"}}}]}, {"uuid": "c35648e4-98a8-4b53-93f4-c9832c9a4772", "name": "load_p1rlv17239_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba567aae-a893-41d3-8fd1-8357d3cab35d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "050f8a43-86e9-440e-9013-a602a5347d35"}}}}, {"uuid": "145622c3-10b0-43f9-b6eb-5fba18da4dc7", "name": "cbe728db-d030-4a08-a9ae-2f266c38827d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8791002615066037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24190904367644575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2d231892-6703-4130-9edf-3084ca95ef2d", "name": "4ea83401-f40a-499f-bbf0-b3f2158897dc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "145622c3-10b0-43f9-b6eb-5fba18da4dc7"}}}]}, {"uuid": "fa50fe3e-5e73-434b-8f50-8a2a6a1d4b63", "name": "load_p1rlv17239_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba567aae-a893-41d3-8fd1-8357d3cab35d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2d231892-6703-4130-9edf-3084ca95ef2d"}}}}, {"uuid": "fcd97511-4190-4064-a54f-9874215e5e8f", "name": "59d5dc07-dbbc-48cc-bfdc-ea9b13fbbd10_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.664483224984605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9538644530515166, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e271eab7-9cd8-42f1-b8c0-0c11acf307d8", "name": "52fd7431-2ac2-402d-ac11-d8f5d4afe61b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fcd97511-4190-4064-a54f-9874215e5e8f"}}}]}, {"uuid": "d2090903-e858-43d0-bed5-eacf872228dd", "name": "load_p1rlv17246_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acfdbe95-2d82-463a-9d1f-6fd2688adf16"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e271eab7-9cd8-42f1-b8c0-0c11acf307d8"}}}}, {"uuid": "1e737e3c-83b0-4326-bf8f-b6acae50638d", "name": "9ee4961e-7303-4ff5-834c-32b092f8dde4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.664483224984605, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9538644530515166, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d2309fed-4bd6-4ec1-a07c-9776f9d23797", "name": "d8a40c85-27ed-4609-81cb-53106e525a8b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1e737e3c-83b0-4326-bf8f-b6acae50638d"}}}]}, {"uuid": "6deb03f4-71f9-4740-b29a-428e44a88afa", "name": "load_p1rlv17246_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acfdbe95-2d82-463a-9d1f-6fd2688adf16"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d2309fed-4bd6-4ec1-a07c-9776f9d23797"}}}}, {"uuid": "5b8bf031-4224-4dba-9afb-32fd4c970315", "name": "131b04d8-6670-4981-b729-cd45182c9312_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7073298240395912, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.27247283022117846, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ecdec3fa-0fe5-4adc-94e0-b2686c04e60d", "name": "2f40d2d5-37f0-45ff-bdf2-74489ec2cbf1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b8bf031-4224-4dba-9afb-32fd4c970315"}}}]}, {"uuid": "2a0175b3-9542-4c41-845a-5ef0855a6df3", "name": "load_p1rlv17280_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac80cbea-e10a-491a-ba36-06e9fcf74217"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ecdec3fa-0fe5-4adc-94e0-b2686c04e60d"}}}}, {"uuid": "d9fa4f4e-b7d1-4935-8353-239744c09582", "name": "88ca2756-2a7b-46ec-a7bb-074c65e03a8f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7073298240395912, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.27247283022117846, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9a872ec0-9bac-4b01-9536-7be722032b24", "name": "ad7fd0b0-d4bf-4805-9b76-018d3d997a28", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d9fa4f4e-b7d1-4935-8353-239744c09582"}}}]}, {"uuid": "711295f8-9158-44a8-8b6f-5f1498447996", "name": "load_p1rlv17280_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac80cbea-e10a-491a-ba36-06e9fcf74217"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9a872ec0-9bac-4b01-9536-7be722032b24"}}}}, {"uuid": "67a9a2c0-4038-4037-a2e9-7ff562687f15", "name": "23c1537f-8d8f-42ec-8c6b-6d3010087c0a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7675749799903273, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6204429178040327, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f8fc3ba-b7a7-436a-8419-5672be6c1c6a", "name": "a2d63641-53a1-4222-9271-95b4e71989a1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "67a9a2c0-4038-4037-a2e9-7ff562687f15"}}}]}, {"uuid": "b0ea80f7-43ec-44ce-afb5-79f392497f53", "name": "load_p1rlv17291_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04388b89-16fc-40b3-a060-5bc52032874e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f8fc3ba-b7a7-436a-8419-5672be6c1c6a"}}}}, {"uuid": "6676d674-277d-4c80-8d60-99a5c2e5f3c4", "name": "e6c387a3-ca6b-4306-accd-7e17124f02ae_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7675749799903273, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6204429178040327, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "292dc273-0cd2-4e35-aa1c-0c07bfb32add", "name": "0fd2deb4-9d5f-4a37-8208-13600ea0174d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6676d674-277d-4c80-8d60-99a5c2e5f3c4"}}}]}, {"uuid": "8b720fc4-a00e-41f8-9c68-51dc8f90af7f", "name": "load_p1rlv17291_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04388b89-16fc-40b3-a060-5bc52032874e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "292dc273-0cd2-4e35-aa1c-0c07bfb32add"}}}}, {"uuid": "10e86e9d-ca57-4db7-90d5-16cae37b75ba", "name": "80cbee2f-3ab1-4e74-937c-8f4e543a84e4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8744605841296944, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5892496700768608, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "256c9e8a-d0d8-4d4f-b53b-36e6005cab1b", "name": "30d361c3-0aab-4780-8248-faffdfce3d12", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "10e86e9d-ca57-4db7-90d5-16cae37b75ba"}}}]}, {"uuid": "ddea90dc-2e99-4402-91a1-84c31229f44e", "name": "load_p1rlv17303_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04eb7e32-e372-4cb0-94a7-ee418f400bda"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "256c9e8a-d0d8-4d4f-b53b-36e6005cab1b"}}}}, {"uuid": "2069dad0-4b69-4bcb-8fbf-3000584dfdbc", "name": "252eef92-b83b-4753-a651-aa2df01fb01c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.8744605841296944, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5892496700768608, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4205920b-6ffd-4d2e-9965-9c548b00f7ca", "name": "29b34c55-66ec-4ca0-8156-33a3be3c9160", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2069dad0-4b69-4bcb-8fbf-3000584dfdbc"}}}]}, {"uuid": "5a0db9b8-a303-4e8f-8ce6-48034af5b2ce", "name": "load_p1rlv17303_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04eb7e32-e372-4cb0-94a7-ee418f400bda"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4205920b-6ffd-4d2e-9965-9c548b00f7ca"}}}}, {"uuid": "39fd1708-e184-4b5d-9036-627aa4903a72", "name": "f2a8f814-c6b3-47c8-b5d0-91d7bc1c9606_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.446531565278448, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9314679219387375, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2166fe2c-b301-44e5-a91b-374f6818f1b4", "name": "74c3edab-08c0-42f4-9445-44987245fb8f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "39fd1708-e184-4b5d-9036-627aa4903a72"}}}]}, {"uuid": "116e8dc6-181a-4c69-85f1-d6db4517f88d", "name": "load_p1rlv17311_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84ebd9bb-dc50-483d-a3c6-044682d4020c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2166fe2c-b301-44e5-a91b-374f6818f1b4"}}}}, {"uuid": "d45d4101-f6dd-4c03-8d23-4e324061add4", "name": "f28f4b69-0589-4998-834b-45744772adcb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.446531565278448, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9314679219387375, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a4efd325-ab67-4330-8d7d-a62e6aec7d3e", "name": "183af1aa-33b5-47d7-895a-7bab90843791", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d45d4101-f6dd-4c03-8d23-4e324061add4"}}}]}, {"uuid": "b50f50bb-1c6e-428f-87db-f970d8bd0257", "name": "load_p1rlv17311_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84ebd9bb-dc50-483d-a3c6-044682d4020c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a4efd325-ab67-4330-8d7d-a62e6aec7d3e"}}}}, {"uuid": "3b56692e-8300-4a54-b121-6b2f3e460062", "name": "6110bf2f-bfca-4a3b-9a92-e766fd8b17b9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.1528026683641635, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1483162213006746, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "025f9caf-f565-4cfd-afee-aee4bbdd1814", "name": "ed801105-f860-41fb-b2cb-97abb0aba42d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3b56692e-8300-4a54-b121-6b2f3e460062"}}}]}, {"uuid": "dc660c7e-6795-4d0c-b2d2-a293b5ad6c20", "name": "load_p1rlv17345_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ead5953-70f2-4db2-ba4d-d203c91d85c1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "025f9caf-f565-4cfd-afee-aee4bbdd1814"}}}}, {"uuid": "e3547a41-5cc3-4d5a-b8c1-443e4d8458eb", "name": "2c56459d-f1c9-4ea4-a11a-6145c16e5d9c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.1528026683641635, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.1483162213006746, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "66a2f399-d485-4762-85b5-8a8609023535", "name": "396cda2b-d69c-48ed-a339-5569d54a14c4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e3547a41-5cc3-4d5a-b8c1-443e4d8458eb"}}}]}, {"uuid": "c7c05374-7e21-4d77-91d3-ef29d9ff446d", "name": "load_p1rlv17345_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ead5953-70f2-4db2-ba4d-d203c91d85c1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "66a2f399-d485-4762-85b5-8a8609023535"}}}}, {"uuid": "54c6339c-d9dd-4aee-9394-c9e0b47a0ad4", "name": "2142fbb6-48f3-4fa5-96e6-6078c0281251_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5261964028176471, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5335215898246958, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "38a6dfe5-5a67-41af-8cdb-f85c2ed8074f", "name": "3abae5ba-902f-489b-ac67-d322cfc39009", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "54c6339c-d9dd-4aee-9394-c9e0b47a0ad4"}}}]}, {"uuid": "ef1c7d14-31c7-428c-9e7f-77573cc919e4", "name": "load_p1rlv17347_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d98640c6-d8aa-44e4-9ecf-5998152d3f7d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "38a6dfe5-5a67-41af-8cdb-f85c2ed8074f"}}}}, {"uuid": "d8bdd3b2-05e8-4baa-989c-71c97851d72a", "name": "478c6353-119e-4c78-99f0-8843ffd338db_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5261964028176471, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5335215898246958, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "383e8d73-e53c-4d55-8738-c313c36771e2", "name": "17dae6e6-7c19-4bae-b2cf-b0cc703ca8d4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d8bdd3b2-05e8-4baa-989c-71c97851d72a"}}}]}, {"uuid": "e63b5a6b-93d0-430a-8209-4d24137aebea", "name": "load_p1rlv17347_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d98640c6-d8aa-44e4-9ecf-5998152d3f7d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "383e8d73-e53c-4d55-8738-c313c36771e2"}}}}, {"uuid": "ae5cf2b9-af7a-496d-94ee-9bf57047dee6", "name": "e5e8940f-84fa-4ec3-8975-714342c23e01_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1461342593009323, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5165512162199262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6fab1a1c-4a75-4dd4-930a-b92164297677", "name": "a37d4c59-cf96-4e28-b72c-4b0f54142d95", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ae5cf2b9-af7a-496d-94ee-9bf57047dee6"}}}]}, {"uuid": "0db124db-f2cf-452e-af15-005da2d72994", "name": "load_p1rlv17351_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2695decb-d268-46b2-8604-9c33dc90518b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6fab1a1c-4a75-4dd4-930a-b92164297677"}}}}, {"uuid": "72d51562-9cfa-4874-ab5b-1a14664df786", "name": "4c5373c5-b67d-4963-ad2a-c14c49a86058_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.1461342593009323, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5165512162199262, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "864ed71a-eb04-45e5-b8fa-07574a13b6e3", "name": "73a98dfa-1d29-4054-a6e4-d627fa9e4407", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72d51562-9cfa-4874-ab5b-1a14664df786"}}}]}, {"uuid": "2cb117f5-e198-4644-b51e-fea0f165b412", "name": "load_p1rlv17351_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2695decb-d268-46b2-8604-9c33dc90518b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "864ed71a-eb04-45e5-b8fa-07574a13b6e3"}}}}, {"uuid": "a1508534-c554-4a7d-ac1d-5ad0675b7b51", "name": "3ca2e239-a8d3-48d2-8295-0bd4717ea50c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3232710990419903, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5137832846214487, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8f36cea0-29e7-467b-8526-a245406e1116", "name": "7874fd6c-3bb4-4bc4-ba13-b84a17dc0816", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a1508534-c554-4a7d-ac1d-5ad0675b7b51"}}}]}, {"uuid": "8295aded-e172-4d6b-a633-3b9c8e2455d9", "name": "load_p1rlv17353_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f34e3e4e-bebd-4148-bcc7-cbfbecd73a2f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8f36cea0-29e7-467b-8526-a245406e1116"}}}}, {"uuid": "c9828856-d2c7-48b9-8226-5488cececd61", "name": "24908e2e-d087-4018-b785-36f46ac813b3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3232710990419903, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5137832846214487, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0add286a-19e4-4b8d-9bda-00b9c2e5fcfa", "name": "a7a56e81-5fdc-4f18-baf3-05794ccd7f2e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c9828856-d2c7-48b9-8226-5488cececd61"}}}]}, {"uuid": "2767aad3-6719-4959-afa3-9482f210f809", "name": "load_p1rlv17353_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f34e3e4e-bebd-4148-bcc7-cbfbecd73a2f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0add286a-19e4-4b8d-9bda-00b9c2e5fcfa"}}}}, {"uuid": "9bc673b5-7b9b-4aa3-ad4e-22d7ec4068b9", "name": "0f4380b6-64d1-427f-8eb3-dd485b015c70_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5604078463831266, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5882122505209306, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "56dc1c65-0c11-445a-a030-11c2775fcfe1", "name": "f4992301-55dc-469d-bbd6-a908b8faa4c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9bc673b5-7b9b-4aa3-ad4e-22d7ec4068b9"}}}]}, {"uuid": "9fe63a69-17bf-46d7-8bc0-704c3f433fae", "name": "load_p1rlv17357_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf6f74e5-7aa3-4333-bd37-3ce486d54a01"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "56dc1c65-0c11-445a-a030-11c2775fcfe1"}}}}, {"uuid": "8d77143d-1380-4250-a50a-e2244879c93d", "name": "c833d713-1517-4209-bc87-50c6feb870d5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5604078463831266, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5882122505209306, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "60323c30-163d-4b00-8887-89f05a5c7679", "name": "ad5709c4-84f7-4133-b49e-13f5194ccf6e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8d77143d-1380-4250-a50a-e2244879c93d"}}}]}, {"uuid": "fa9b2054-5253-4415-8889-259ad0b84cb5", "name": "load_p1rlv17357_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf6f74e5-7aa3-4333-bd37-3ce486d54a01"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "60323c30-163d-4b00-8887-89f05a5c7679"}}}}, {"uuid": "0004e21c-fcf1-4336-8757-a830465658bd", "name": "7252e071-aae1-44aa-a36f-3458e438804d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.567401274738218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6497123013243786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b2137268-c524-4b5f-a351-ffca79fa6184", "name": "c96b7d7f-9fbb-4a4e-ac22-6c17f2a937e0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0004e21c-fcf1-4336-8757-a830465658bd"}}}]}, {"uuid": "5866fcc4-8763-4e06-8c22-e45bba83eeda", "name": "load_p1rlv17361_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c705333f-6f1a-4a76-a02e-eaa859e99b70"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b2137268-c524-4b5f-a351-ffca79fa6184"}}}}, {"uuid": "aa0b02dc-dd07-40da-953a-4563476e6b85", "name": "583fa5ad-46f4-4b34-a1fd-8b637038e0b6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.567401274738218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6497123013243786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3c48eb75-79db-455e-acea-d04d9228136e", "name": "40a2a226-9af9-465a-98a1-30ac408dc218", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aa0b02dc-dd07-40da-953a-4563476e6b85"}}}]}, {"uuid": "df57747a-1083-4403-b872-5fa1c16e3951", "name": "load_p1rlv17361_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c705333f-6f1a-4a76-a02e-eaa859e99b70"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3c48eb75-79db-455e-acea-d04d9228136e"}}}}, {"uuid": "21bb361e-140f-456c-867f-44050003f17a", "name": "a83313d8-cf7c-4295-8b8f-b5ccfde74f81_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.582045467287543, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.1165769169460202, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0344d223-50ec-43ff-9c12-5c3fae83d370", "name": "652b3ce1-f545-4216-a860-97b04ba23934", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "21bb361e-140f-456c-867f-44050003f17a"}}}]}, {"uuid": "9406461e-6e4c-4502-a0a6-9614beb56faf", "name": "load_p1rlv17378_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08709e25-b030-4801-ae00-c4879556d8b1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0344d223-50ec-43ff-9c12-5c3fae83d370"}}}}, {"uuid": "713e7ec4-ff6e-4d92-b490-46362a155cb1", "name": "1ac7f2e1-6b1d-4883-afdd-319145a5ce64_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 14.582045467287543, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.1165769169460202, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d0345c42-36a9-4e16-95a9-4918e096f297", "name": "37bd6084-79d6-414b-a304-86a2d943c6a4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "713e7ec4-ff6e-4d92-b490-46362a155cb1"}}}]}, {"uuid": "9e157d0c-0565-4de8-92f7-1bc70e4014bb", "name": "load_p1rlv17378_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08709e25-b030-4801-ae00-c4879556d8b1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d0345c42-36a9-4e16-95a9-4918e096f297"}}}}, {"uuid": "43bb55d1-718c-46de-8ca2-64642aa77b21", "name": "cb9facd3-eec8-422b-8dc2-06031991e10e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.833192950896713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0261472784856227, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e11461e0-e866-4176-85d0-d4ba5f5eaaf2", "name": "f44f14d3-16b1-42c3-9d87-a8f0f6e278f6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "43bb55d1-718c-46de-8ca2-64642aa77b21"}}}]}, {"uuid": "3c4a47db-8ffa-4ba2-852d-3df52e0e6aa6", "name": "load_p1rlv17383_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e1ad135-904d-47ed-ae74-32b38e1c2f88"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e11461e0-e866-4176-85d0-d4ba5f5eaaf2"}}}}, {"uuid": "6fe8413f-9acd-4df9-804d-3d71bd46fca3", "name": "b1eaef3e-9804-4d8a-a91a-acc53f697d5a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.833192950896713, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.0261472784856227, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6770a518-c900-41f2-a123-1488f7553cb8", "name": "259d81e9-8e67-4f7f-b719-ca0ba0de5c84", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6fe8413f-9acd-4df9-804d-3d71bd46fca3"}}}]}, {"uuid": "5212b428-d8b3-4f9a-a450-7f11c353f06e", "name": "load_p1rlv17383_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e1ad135-904d-47ed-ae74-32b38e1c2f88"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6770a518-c900-41f2-a123-1488f7553cb8"}}}}, {"uuid": "4ab1034a-22fe-4aaf-bf2b-3173f0915153", "name": "1e4d1724-790f-4aa3-a8d2-7ddcac6701a7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4147996191793286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7367936950300052, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "806d8710-c2d5-4753-b051-9ab47963f96f", "name": "7d275180-3049-4299-b88f-ef15fa8c8e3b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4ab1034a-22fe-4aaf-bf2b-3173f0915153"}}}]}, {"uuid": "356607c3-77d9-4189-9190-1ddafe1a961f", "name": "load_p1rlv17385_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e835b413-3307-49ef-ad69-cf18a5ae7cfb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "806d8710-c2d5-4753-b051-9ab47963f96f"}}}}, {"uuid": "838a242a-9611-443f-8c74-a88ff07a6caf", "name": "b2524670-8066-4464-960c-cb129261ded3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4147996191793286, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7367936950300052, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4b5a2eae-e238-40d8-8baf-092e6388f195", "name": "dc596592-87c6-4f2e-aa82-a131c6439d44", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "838a242a-9611-443f-8c74-a88ff07a6caf"}}}]}, {"uuid": "4cc6a621-48bf-468c-8e56-766fac8208f2", "name": "load_p1rlv17385_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e835b413-3307-49ef-ad69-cf18a5ae7cfb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4b5a2eae-e238-40d8-8baf-092e6388f195"}}}}, {"uuid": "88b390e3-39d8-45bf-ae83-4d940000f48d", "name": "44b92c1f-cb76-49b0-900f-2ce73682d7aa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4341422169696036, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7357531788704136, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2965e5ae-a370-491d-bdb3-cc58fce2fb1b", "name": "c6281ae0-d87a-4b54-8fd1-9841a114e928", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "88b390e3-39d8-45bf-ae83-4d940000f48d"}}}]}, {"uuid": "697b77fe-e657-4fd7-b89b-d800d852f3a8", "name": "load_p1rlv17387_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "55382019-a1a5-40fd-b90a-072af40c2258"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2965e5ae-a370-491d-bdb3-cc58fce2fb1b"}}}}, {"uuid": "52de8749-2ec3-468f-a447-0c09d80b121f", "name": "b3e054d4-a5c9-4c00-bfb1-417a6151ff6c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4341422169696036, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7357531788704136, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "62c675f5-9c89-4388-b098-c8b697565974", "name": "ac2db679-d9a8-4f39-9764-967a6122356c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "52de8749-2ec3-468f-a447-0c09d80b121f"}}}]}, {"uuid": "4fa2fec5-5280-47dd-ace4-31d79610be5d", "name": "load_p1rlv17387_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "55382019-a1a5-40fd-b90a-072af40c2258"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "62c675f5-9c89-4388-b098-c8b697565974"}}}}, {"uuid": "0ca0f37c-a67b-40c0-945f-75485e693773", "name": "d89e5876-38f6-491b-ac24-1332746712e1_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3557486353305213, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.524803205527562, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "229a6a7d-4723-41f9-b305-086b43fbf58e", "name": "b786ccbb-08f3-45f5-8f8d-e4fcf7fbd606", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0ca0f37c-a67b-40c0-945f-75485e693773"}}}]}, {"uuid": "f1f220d6-2c2d-4e91-bba9-6db42c260a03", "name": "load_p1rlv17391_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "169a22de-bb0a-4056-8910-151125c4ff9e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "229a6a7d-4723-41f9-b305-086b43fbf58e"}}}}, {"uuid": "3dbbb271-6748-435a-ac2a-880d5a37dc41", "name": "92c492ce-5b88-465c-8762-6a7de937bdd0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.3557486353305213, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.524803205527562, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "187b5a26-62fe-4ec7-8514-c24ec27c8921", "name": "08f3dbc1-7f29-4b75-93f8-50b00087a8c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3dbbb271-6748-435a-ac2a-880d5a37dc41"}}}]}, {"uuid": "1002dba4-77bd-4cc9-b627-2a849d502d9b", "name": "load_p1rlv17391_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "169a22de-bb0a-4056-8910-151125c4ff9e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "187b5a26-62fe-4ec7-8514-c24ec27c8921"}}}}, {"uuid": "7b009349-73d7-4acb-9521-a26b06608d33", "name": "c837bdf3-fdf5-44f6-a1a8-7ee9ec55368f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.0707881481560175, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.1283140369898392, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "579385c8-f0f6-4477-b08a-a8ab9272c314", "name": "b6b4f40e-9c6f-4edf-a93e-c3923f293c9d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b009349-73d7-4acb-9521-a26b06608d33"}}}]}, {"uuid": "bb753700-3f23-44b4-b12e-611167da5587", "name": "load_p1rlv17394_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea560bcb-f930-4f42-ae45-3a60f36fdbb7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "579385c8-f0f6-4477-b08a-a8ab9272c314"}}}}, {"uuid": "3019877e-d0cb-43f8-8ab8-7519b5ad0168", "name": "82621ccf-7bba-48da-acb6-e4a98de4bbbf_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.0707881481560175, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.1283140369898392, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ed8335fc-7c31-4da7-94a9-4666fecbf066", "name": "435980bf-ebd6-4c7b-9691-da263768536d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3019877e-d0cb-43f8-8ab8-7519b5ad0168"}}}]}, {"uuid": "ac8d96c4-d602-4fd1-9be2-5b10ed7c810c", "name": "load_p1rlv17394_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea560bcb-f930-4f42-ae45-3a60f36fdbb7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ed8335fc-7c31-4da7-94a9-4666fecbf066"}}}}, {"uuid": "5a5e5d7a-03e7-4a56-843e-84c1f6073e79", "name": "e496bdb3-1418-4e6b-a79b-952a4ec8d05a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.772705532239135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.33568286747913667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "70f7dfe6-a16a-426e-9286-34c5a396ced9", "name": "2979b272-bbde-4390-9125-d87da755935e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5a5e5d7a-03e7-4a56-843e-84c1f6073e79"}}}]}, {"uuid": "a69d0934-805d-44c8-8035-3bb4e1ad5e76", "name": "load_p1rlv17397_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d38cdffb-41be-48aa-8a03-c6525dd01037"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "70f7dfe6-a16a-426e-9286-34c5a396ced9"}}}}, {"uuid": "f35f7daf-422b-4ca4-af37-55eb6cef9b4c", "name": "8a1965b2-8b0c-4bc1-bc76-807ba9d11f4d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.772705532239135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.33568286747913667, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "dd91b777-3ae2-4333-923c-44c405bace58", "name": "0f76aa58-5610-4d56-bd20-56a677fd9318", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f35f7daf-422b-4ca4-af37-55eb6cef9b4c"}}}]}, {"uuid": "144ad946-e543-4e87-8c77-837a8d8da3b0", "name": "load_p1rlv17397_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d38cdffb-41be-48aa-8a03-c6525dd01037"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "dd91b777-3ae2-4333-923c-44c405bace58"}}}}, {"uuid": "2407d8a8-67ea-4de5-9750-c11eb0683256", "name": "1db87372-bb6e-458b-a85f-4b38c1970474_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.072452566650022, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.19566580727582514, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e7c63da0-a165-46bd-aaf3-9d0575264d2f", "name": "0e15e527-5779-4f67-b1fe-61159d545837", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2407d8a8-67ea-4de5-9750-c11eb0683256"}}}]}, {"uuid": "3c899519-7224-4885-9d02-ee292723af0b", "name": "load_p1rlv17400_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63177299-2842-4e0d-bf17-7bd2b0afe9a2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e7c63da0-a165-46bd-aaf3-9d0575264d2f"}}}}, {"uuid": "3a3f2217-6cfb-4fad-89ac-4d06b8bc5bac", "name": "31309af2-1f78-4d21-9067-f5f127248951_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.072452566650022, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.19566580727582514, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d2669ad4-1f07-4b52-890e-83578641b89f", "name": "fb7a1148-b012-479a-adc2-a72ddc85c28e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3a3f2217-6cfb-4fad-89ac-4d06b8bc5bac"}}}]}, {"uuid": "7ef8ddb5-6d01-40c3-a749-97ba63adcdc0", "name": "load_p1rlv17400_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63177299-2842-4e0d-bf17-7bd2b0afe9a2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d2669ad4-1f07-4b52-890e-83578641b89f"}}}}, {"uuid": "5b874b04-da0b-4a51-bc6f-b387b1b951bd", "name": "59b22aa8-fbba-47e3-ab06-2534e76dd4d8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.799969889792979, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7055837837850989, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "24009d36-0cfe-4c27-8da0-4724252c4a08", "name": "f6c70340-8718-4978-baad-62577cbddc6d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5b874b04-da0b-4a51-bc6f-b387b1b951bd"}}}]}, {"uuid": "d447dc1f-1c26-48c1-a2e3-570c6805d19c", "name": "load_p1rlv17403_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d61897a-cdac-4b4a-8812-8a8692a3d958"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "24009d36-0cfe-4c27-8da0-4724252c4a08"}}}}, {"uuid": "c1bd056d-22a3-4b0d-b9b6-30dab96ccba7", "name": "f5c00162-a7ca-4860-8b51-9d1298ee15be_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.799969889792979, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7055837837850989, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "af5e10e5-e0dc-4186-8e57-3edc6f6e524c", "name": "1efdaafa-c6c4-417f-8ea5-c2cf301c0219", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c1bd056d-22a3-4b0d-b9b6-30dab96ccba7"}}}]}, {"uuid": "764b567c-a4e5-4d1f-a784-9dda29a803e5", "name": "load_p1rlv17403_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d61897a-cdac-4b4a-8812-8a8692a3d958"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "af5e10e5-e0dc-4186-8e57-3edc6f6e524c"}}}}, {"uuid": "5c7e67f9-eb74-4072-bd15-aaf6c3dfadf1", "name": "982ef7b8-e286-439a-ae6c-c7188ec2f61a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2075389461119934, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3167249782629938, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7842d907-a8f8-4936-b8eb-c87fb3c1212a", "name": "37fe09d7-e1c6-460c-82f8-2ecbf0af9189", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5c7e67f9-eb74-4072-bd15-aaf6c3dfadf1"}}}]}, {"uuid": "e5ee68a5-e0bc-4a07-9fde-5f3a7730db64", "name": "load_p1rlv17405_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b50de14e-9a09-4f61-8998-0979f33b0d0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7842d907-a8f8-4936-b8eb-c87fb3c1212a"}}}}, {"uuid": "01b8414f-5666-464c-8250-fe528292c693", "name": "06d7800b-e9df-45f5-8302-dd539204b00e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2075389461119934, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3167249782629938, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b91c17c7-c950-4a98-bfcc-ac5bb84edf1e", "name": "c1b90e55-7f45-45e5-8a76-35326021fb6b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "01b8414f-5666-464c-8250-fe528292c693"}}}]}, {"uuid": "8a18a6a3-16ec-4cb1-a1b9-d836e6e65e29", "name": "load_p1rlv17405_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b50de14e-9a09-4f61-8998-0979f33b0d0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b91c17c7-c950-4a98-bfcc-ac5bb84edf1e"}}}}, {"uuid": "f588d3ad-fa76-478d-a91d-7bfce980b80b", "name": "3aaf73cf-4754-4d6a-a3af-42a02d25ccfd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2162240825393356, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.47013804182089236, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0be405d0-1eca-469c-80fc-ae833e8edba7", "name": "1c3b8c48-1d81-408e-94d1-45c355e21042", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f588d3ad-fa76-478d-a91d-7bfce980b80b"}}}]}, {"uuid": "a79e9642-e380-4811-94a3-a8e3ef214797", "name": "load_p1rlv17407_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65de341c-589f-4bf9-a708-26fcc94a6c0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0be405d0-1eca-469c-80fc-ae833e8edba7"}}}}, {"uuid": "39f99665-53c4-4897-8ee8-39b15c3c2d3d", "name": "90a1466b-6d62-48c2-820f-ff45af8d6778_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2162240825393356, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.47013804182089236, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ce0e992d-7170-43f0-b60a-0bc2db1ddd4f", "name": "5a438f1e-3ff8-47f7-a75c-272825c559c7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "39f99665-53c4-4897-8ee8-39b15c3c2d3d"}}}]}, {"uuid": "43efa592-e32e-40e2-bdd9-1b958d3c908d", "name": "load_p1rlv17407_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65de341c-589f-4bf9-a708-26fcc94a6c0a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ce0e992d-7170-43f0-b60a-0bc2db1ddd4f"}}}}, {"uuid": "9de5024a-5503-4cee-bd35-09ef1bf4e580", "name": "7a92c937-bcf1-473f-aa95-62ac42cde235_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2816928104449037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4107329194522798, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "347d276f-d16b-46bf-99e7-1c5edbff94ab", "name": "aab4f704-c723-4488-9b50-f2debc755a5e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9de5024a-5503-4cee-bd35-09ef1bf4e580"}}}]}, {"uuid": "8350ccd7-b3f4-40f6-85b2-ccce48b7a5cd", "name": "load_p1rlv17415_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86b2527b-73c3-41c4-8ac2-7cb0e8bc2a7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "347d276f-d16b-46bf-99e7-1c5edbff94ab"}}}}, {"uuid": "b65a617e-98cd-4679-b909-11df11aba0ff", "name": "ce339973-1e65-4efc-8f33-b9f2860fe8bb_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2816928104449037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4107329194522798, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "77228ec7-1d24-4bdb-933c-2eef13a771d5", "name": "37f2666b-debc-48db-b76c-446fbf120c0e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b65a617e-98cd-4679-b909-11df11aba0ff"}}}]}, {"uuid": "bd730a82-6946-45dd-849e-314b29a96e03", "name": "load_p1rlv17415_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86b2527b-73c3-41c4-8ac2-7cb0e8bc2a7a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "77228ec7-1d24-4bdb-933c-2eef13a771d5"}}}}, {"uuid": "be257be2-6154-459a-9727-7434eab3ae9b", "name": "71b95e00-0e54-42ef-9fbb-ba7688857464_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.524011463187128, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7498872254128004, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d2e3f0b4-e35d-47aa-aa3c-057777b11819", "name": "16446f09-2dc2-43b1-abdd-bc9b03e70549", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "be257be2-6154-459a-9727-7434eab3ae9b"}}}]}, {"uuid": "aab56419-c994-43b3-acb6-4dc12758f78e", "name": "load_p1rlv17416_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64a56527-23a9-4229-aa25-f6a45f2187f4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d2e3f0b4-e35d-47aa-aa3c-057777b11819"}}}}, {"uuid": "9c6ca403-fd85-4b35-8892-013f17f967c1", "name": "dbeb95f5-8f49-47f6-9494-bd80cecb550e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.524011463187128, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7498872254128004, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fc931318-a8a4-493d-8371-27e3480f96e4", "name": "fea0aa3d-333a-4590-beec-7efce1279967", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9c6ca403-fd85-4b35-8892-013f17f967c1"}}}]}, {"uuid": "9361bc29-535d-4b5e-ab5c-b66b504f9f0c", "name": "load_p1rlv17416_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64a56527-23a9-4229-aa25-f6a45f2187f4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fc931318-a8a4-493d-8371-27e3480f96e4"}}}}, {"uuid": "9476faa4-9250-476c-8b03-68ef2566c80d", "name": "ee8ddc70-1c84-4dee-851c-1e58d1c6a2b7_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.887268818021247, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.0124643291307467, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5031ad5c-b431-4be9-8d68-e0332e5699bb", "name": "52519b40-3f15-4cd1-b12a-27b5543ef4b5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9476faa4-9250-476c-8b03-68ef2566c80d"}}}]}, {"uuid": "c3fa75f3-7af0-4bd3-89e9-711d7614221f", "name": "load_p1rlv17417_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67003f0f-6690-469e-82c0-63949ee5241e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5031ad5c-b431-4be9-8d68-e0332e5699bb"}}}}, {"uuid": "1d75b5b1-a939-4899-9865-3e31ae1af64f", "name": "b9cbac1c-1576-4db1-a031-24fb551f1495_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.887268818021247, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.0124643291307467, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "85a852a4-0bd8-49ab-96ff-d748358a5287", "name": "b9af2d56-3844-4983-92db-339d49d0ef67", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1d75b5b1-a939-4899-9865-3e31ae1af64f"}}}]}, {"uuid": "14c2f474-05ed-47f4-a37f-e4c8361d4cb2", "name": "load_p1rlv17417_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67003f0f-6690-469e-82c0-63949ee5241e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "85a852a4-0bd8-49ab-96ff-d748358a5287"}}}}, {"uuid": "8cbbd0b1-9a4e-45dc-a1c9-b42a1661df65", "name": "3b3605a5-1da1-44ca-8aa7-b65e0fe15dd0_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1219512592986662, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8685822493081499, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c8ae20d1-5b04-4bcc-a716-a7b254a720b4", "name": "7c39d8b1-a023-4667-9efd-77168170d85a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8cbbd0b1-9a4e-45dc-a1c9-b42a1661df65"}}}]}, {"uuid": "73aba28a-da22-4d76-8ef8-a166f2a20c31", "name": "load_p1rlv19574_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf457d88-958c-446a-9584-73be8c609bbe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c8ae20d1-5b04-4bcc-a716-a7b254a720b4"}}}}, {"uuid": "491cda37-a219-453c-bd7a-f818d86d7c69", "name": "d5bedc31-12ea-41fa-8b0e-3b77d6a70181_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.1219512592986662, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8685822493081499, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "88ee732c-b169-4bbe-8ff7-5080f5252a9e", "name": "b827c4c3-d0e7-4405-a386-12643b337264", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "491cda37-a219-453c-bd7a-f818d86d7c69"}}}]}, {"uuid": "ebd41626-5df8-4131-9e56-6557ffebf1f1", "name": "load_p1rlv19574_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf457d88-958c-446a-9584-73be8c609bbe"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "88ee732c-b169-4bbe-8ff7-5080f5252a9e"}}}}, {"uuid": "01b83cc5-088b-4535-b8c6-2f6d119cdc29", "name": "e9084385-43f4-4dcc-a766-b59a6f16cf00_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.817160338362793, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.8654854383625104, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2e5ea7d6-5d3e-4ab2-a2a8-f4b47aceb960", "name": "434ed16a-7e6f-4fc1-9fab-5afd87d35143", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "01b83cc5-088b-4535-b8c6-2f6d119cdc29"}}}]}, {"uuid": "ff4b85f9-f026-4da1-bb90-b0daebe67df4", "name": "load_p1rlv19608_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f917b142-d59f-4a51-8c3b-913feb53411d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2e5ea7d6-5d3e-4ab2-a2a8-f4b47aceb960"}}}}, {"uuid": "fc108728-c806-46c7-9d22-68ded33066cc", "name": "c02ebb55-f9f3-468b-9fc6-b92bc289e1f3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.817160338362793, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.8654854383625104, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "31ed6c2a-ae9e-4a5e-aa55-bef73c08d0d7", "name": "c516f3fc-4e7c-484f-9646-592d6aba09da", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "fc108728-c806-46c7-9d22-68ded33066cc"}}}]}, {"uuid": "cd9175ba-3277-41e9-9fe7-929229dfdf54", "name": "load_p1rlv19608_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f917b142-d59f-4a51-8c3b-913feb53411d"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "31ed6c2a-ae9e-4a5e-aa55-bef73c08d0d7"}}}}, {"uuid": "861b9adc-05fe-4dee-ae1f-f543c31f61eb", "name": "48772389-aa31-4394-b8e2-a2d7dccbce94_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.931347600748843, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.97768534997531, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cf3c100b-93d4-4c17-8d10-cdb0d190a302", "name": "e2672745-f7ac-400b-b48c-7b1c6bc1726e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "861b9adc-05fe-4dee-ae1f-f543c31f61eb"}}}]}, {"uuid": "3eead1e5-07f0-4ee7-84c6-07dcd4f130b0", "name": "load_p1rlv19610_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "813f887e-6807-4ffc-90bf-bd30cde9a9df"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cf3c100b-93d4-4c17-8d10-cdb0d190a302"}}}}, {"uuid": "01550101-b582-41aa-ae25-30f44134001d", "name": "28fec7d8-95f1-4a68-b4d3-a15cbfab2792_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.931347600748843, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.97768534997531, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3e1afdcd-ce9c-4989-8c68-15db2c7114bf", "name": "8255ef47-9ab6-4f7d-b7e6-8ef9d13464aa", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "01550101-b582-41aa-ae25-30f44134001d"}}}]}, {"uuid": "c27da2d6-a9d3-47c2-9056-b49f5f2fff1f", "name": "load_p1rlv19610_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "813f887e-6807-4ffc-90bf-bd30cde9a9df"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3e1afdcd-ce9c-4989-8c68-15db2c7114bf"}}}}, {"uuid": "5985b63c-147a-4326-bafe-41ba848dea30", "name": "8638f04b-97f9-478b-8801-4cc733147fde_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5877230897388055, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4388767979233367, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "795a41ee-4f11-4851-bb52-ec20deb75787", "name": "52439e00-1f5a-4a03-badb-53c010a26c68", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5985b63c-147a-4326-bafe-41ba848dea30"}}}]}, {"uuid": "1296b321-b4be-4bed-8bf8-b44a0438459a", "name": "load_p1rlv19616_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be1b9922-2426-4726-9e5a-bcd33f444b57"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "795a41ee-4f11-4851-bb52-ec20deb75787"}}}}, {"uuid": "2d397e2e-5344-4333-820f-7894baf42aef", "name": "79d92001-bc92-4823-9e1c-851734be8689_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5877230897388055, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4388767979233367, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1c32a656-137e-4d99-97c7-0e842dae33e9", "name": "80876c3d-d8c5-47d7-ae76-e3a9ab056fa7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2d397e2e-5344-4333-820f-7894baf42aef"}}}]}, {"uuid": "2a53dcc4-8c69-4632-b1af-ef95e2bbb525", "name": "load_p1rlv19616_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be1b9922-2426-4726-9e5a-bcd33f444b57"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1c32a656-137e-4d99-97c7-0e842dae33e9"}}}}, {"uuid": "3ffd9aeb-ffaf-4c77-988f-21934028f3fb", "name": "a70da804-57f4-494b-905e-f44e64ad7b5f_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.925260736902077, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.726135012516628, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "00c79078-4ffb-4f0f-855a-ca8dc265cd1e", "name": "272f4a4f-b213-4932-b85f-8e9af0e5892c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3ffd9aeb-ffaf-4c77-988f-21934028f3fb"}}}]}, {"uuid": "c74b9f6c-f9ba-4508-a774-4728d5a2ee91", "name": "load_p1rlv19640_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e90f763-682e-4771-976c-9cd736b72133"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "00c79078-4ffb-4f0f-855a-ca8dc265cd1e"}}}}, {"uuid": "c23552af-3ba4-41b2-b568-a394025c6c76", "name": "62b10e40-2852-42e5-9e8e-a772162d2bc9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.925260736902077, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.726135012516628, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6bed2d9c-e8f4-4ae5-a8c9-40896dc8e08e", "name": "3f9169a6-f8b4-41a8-b7de-17d6058ae1ac", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c23552af-3ba4-41b2-b568-a394025c6c76"}}}]}, {"uuid": "a05f7e5d-2673-4d13-a1c9-eef49f17ca26", "name": "load_p1rlv19640_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e90f763-682e-4771-976c-9cd736b72133"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6bed2d9c-e8f4-4ae5-a8c9-40896dc8e08e"}}}}, {"uuid": "56027744-baa0-42d5-8b68-edfd1bf583b5", "name": "bd45c2ed-6be0-4f81-bd1e-36effbf40114_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3571348598185444, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7897285261495656, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b736c69d-5be1-415c-a425-ec5654f8f039", "name": "a23be684-93ce-4cd6-becf-d7a52813160e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "56027744-baa0-42d5-8b68-edfd1bf583b5"}}}]}, {"uuid": "592c8ae4-e706-4b2d-a646-93ff39996f17", "name": "load_p1rlv19643_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f0e181a-fa89-4c5d-a1cb-6080f91331da"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b736c69d-5be1-415c-a425-ec5654f8f039"}}}}, {"uuid": "c814fe75-4519-48fa-ad9a-2661876cb633", "name": "1980c37a-587b-4e2b-9f3f-d44f334738a3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3571348598185444, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7897285261495656, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fe957262-5f7c-47d7-90b5-8f04f058c6e9", "name": "75889327-7bc0-4064-96ce-be904f063c04", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c814fe75-4519-48fa-ad9a-2661876cb633"}}}]}, {"uuid": "b694819c-01b7-4cb7-a06a-d517d4bd8c90", "name": "load_p1rlv19643_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f0e181a-fa89-4c5d-a1cb-6080f91331da"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fe957262-5f7c-47d7-90b5-8f04f058c6e9"}}}}, {"uuid": "84877362-3505-4637-8a0a-cdac5d81880b", "name": "e9b04e35-cdbd-4958-a7bb-35daa42ee745_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.354599726773856, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.636709731909327, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "50de177e-e986-4594-8655-d4e28e80b481", "name": "3645d95c-8b84-4396-820b-2a6475d87400", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "84877362-3505-4637-8a0a-cdac5d81880b"}}}]}, {"uuid": "de328b1d-637f-4e00-8587-c7674fc4b3e2", "name": "load_p1rlv19645_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7efbb32-55d4-409b-a37f-bf01d0620d40"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "50de177e-e986-4594-8655-d4e28e80b481"}}}}, {"uuid": "1c560954-9a26-45dc-824c-d2fd2586fc48", "name": "41a3ab7d-0a41-4f58-b572-b432521ee0df_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.354599726773856, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.636709731909327, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d50067a1-8c81-4f68-954a-fc8fab41c905", "name": "e0e37918-3471-4814-afda-69fb3338c899", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1c560954-9a26-45dc-824c-d2fd2586fc48"}}}]}, {"uuid": "db057238-fe08-440a-8938-d471bbdb491b", "name": "load_p1rlv19645_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7efbb32-55d4-409b-a37f-bf01d0620d40"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d50067a1-8c81-4f68-954a-fc8fab41c905"}}}}, {"uuid": "5cfa9f24-fb2e-49eb-9407-fed20b015f3b", "name": "d379a36f-5756-47b3-8ca0-a98f811e3598_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1763634802125313, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8050824744595734, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5c1a0340-3f57-4656-98ff-967ad63d2363", "name": "73089cdc-992d-4e0e-91de-9f8dea577196", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5cfa9f24-fb2e-49eb-9407-fed20b015f3b"}}}]}, {"uuid": "b5a20c0a-b9dd-4aba-8196-cf6292d1eb80", "name": "load_p1rlv19683_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19894180-0890-4585-b4e2-55500af3c41a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5c1a0340-3f57-4656-98ff-967ad63d2363"}}}}, {"uuid": "20fee792-37d4-4207-9023-dd663ac217a8", "name": "d4b61c7e-2966-4cd3-86b5-207b3da141d7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.1763634802125313, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.8050824744595734, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8a455b71-a883-4b54-abf0-167c0928995b", "name": "4d363972-a584-4fc8-8320-0827e3556b23", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "20fee792-37d4-4207-9023-dd663ac217a8"}}}]}, {"uuid": "36f8c773-9a3e-4bae-b0db-fc25a31d0d23", "name": "load_p1rlv19683_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19894180-0890-4585-b4e2-55500af3c41a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8a455b71-a883-4b54-abf0-167c0928995b"}}}}, {"uuid": "98cab855-e394-4444-8423-672ff982150f", "name": "b1b5f5e3-d8d1-4f6f-8b7b-4b1c42aaf35b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7055277650263714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24030088917661724, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0a85f6b6-de93-4523-9c7d-1ace1ea283ec", "name": "aae51e6e-b2e7-4c5f-b5d0-d72d3b04a775", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "98cab855-e394-4444-8423-672ff982150f"}}}]}, {"uuid": "2adf5309-aace-4f00-bed6-ed4e7bf836ce", "name": "load_p1rlv37689_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f827fe9e-1ffe-456c-a57b-c3374aef8ad8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0a85f6b6-de93-4523-9c7d-1ace1ea283ec"}}}}, {"uuid": "c87318a7-0a2d-4353-959c-35db301a0857", "name": "2d96a672-ef1f-4027-9e52-530ec682c50e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7055277650263714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24030088917661724, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8ec9c9b7-ab9f-491f-9c1e-32faf27ddc30", "name": "c7f10edc-5d68-4589-89e7-b23d4b7e966b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c87318a7-0a2d-4353-959c-35db301a0857"}}}]}, {"uuid": "858d9eec-d859-4213-9573-c97d163c8c71", "name": "load_p1rlv37689_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f827fe9e-1ffe-456c-a57b-c3374aef8ad8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8ec9c9b7-ab9f-491f-9c1e-32faf27ddc30"}}}}, {"uuid": "86aabb6c-bae3-4a95-8565-6a0e0c767b23", "name": "0404afe2-c99a-439e-bec4-76d53cb6dc65_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.991433457795887, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5982568468826307, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6b10a72c-3057-428c-b0c4-5cd3762cd47c", "name": "623fd40d-3aab-4ef4-96dc-6464c1c13bff", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "86aabb6c-bae3-4a95-8565-6a0e0c767b23"}}}]}, {"uuid": "2b4781d6-4030-4d0b-9b8d-26f217c668e9", "name": "load_p1rlv37691_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da3cd593-6f05-41ba-9609-f6f1e307e998"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6b10a72c-3057-428c-b0c4-5cd3762cd47c"}}}}, {"uuid": "5493cb3e-8215-40c5-9d74-817a0fa2af4a", "name": "7dd65da8-bc6e-404d-9358-d414e807e6df_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.991433457795887, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5982568468826307, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b0f43b4f-d9a9-4d34-bf7f-629916a21f88", "name": "c48de185-469d-4a88-bc12-b03777829130", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5493cb3e-8215-40c5-9d74-817a0fa2af4a"}}}]}, {"uuid": "4561c13f-6bf9-4990-a9e7-23a58b2df2e8", "name": "load_p1rlv37691_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da3cd593-6f05-41ba-9609-f6f1e307e998"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b0f43b4f-d9a9-4d34-bf7f-629916a21f88"}}}}, {"uuid": "c77b0fe6-fd6d-423f-9782-f42f4e139504", "name": "3d48ae85-0040-459a-9849-d48248b838ae_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9233060787231575, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.431469772224645, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8b877d53-04ab-4102-874b-cb892fa21f1f", "name": "0011e870-a629-4810-b98a-1dcd94344fa9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c77b0fe6-fd6d-423f-9782-f42f4e139504"}}}]}, {"uuid": "c4eccd81-0ac9-473f-b1b0-50cd3a52c637", "name": "load_p1rlv37703_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01c9efda-0adf-4932-8f54-2938964371d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8b877d53-04ab-4102-874b-cb892fa21f1f"}}}}, {"uuid": "83dfc415-cd1b-40d8-ad51-de06357e06e5", "name": "fbc35b91-860a-4f01-aeea-64536975e4c5_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9233060787231575, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.431469772224645, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0691e60b-1d86-4f19-b917-91d72314e28f", "name": "9e6c4158-1c0b-4ddb-917a-70f78209c62b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "83dfc415-cd1b-40d8-ad51-de06357e06e5"}}}]}, {"uuid": "2653101b-973b-4458-840e-2d2e1856bb38", "name": "load_p1rlv37703_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01c9efda-0adf-4932-8f54-2938964371d2"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "0691e60b-1d86-4f19-b917-91d72314e28f"}}}}, {"uuid": "1a073c58-9dd9-412e-a2fa-dff5fafef051", "name": "f58579e3-c492-435b-a453-142e6abb9e9c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5500863393357383, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3576036143879098, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a7e703dd-da55-44a3-9e7c-14d344c4d2fc", "name": "62ec24a3-0acd-41eb-ba42-3ffd327e1896", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1a073c58-9dd9-412e-a2fa-dff5fafef051"}}}]}, {"uuid": "cc3f5d8c-a0ce-49d0-920a-f2fa6fddc0a1", "name": "load_p1rlv37710_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38bda697-2888-467e-bab0-62896a62503f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a7e703dd-da55-44a3-9e7c-14d344c4d2fc"}}}}, {"uuid": "b7358bdb-3dff-4dd8-a8b7-700381fa7043", "name": "ccf907b8-6bd1-45fe-bafe-b26b9ecbaf16_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5500863393357383, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3576036143879098, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "394f38b0-a2d4-48fe-b92e-e2df4d1a8720", "name": "1195b5b4-2083-4043-a818-76e24534b81d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b7358bdb-3dff-4dd8-a8b7-700381fa7043"}}}]}, {"uuid": "534db35e-7b40-4f9d-a0fd-a97b5e54190a", "name": "load_p1rlv37710_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38bda697-2888-467e-bab0-62896a62503f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "394f38b0-a2d4-48fe-b92e-e2df4d1a8720"}}}}, {"uuid": "6f56ae76-1918-43f7-89a3-77b983b8bb29", "name": "b722e849-b111-4203-855b-f505ba11eb7b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2045141672666357, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3046267940472902, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b364fae8-133e-49f4-b5a3-761aad2becc9", "name": "f4ac8e2a-7c9b-4795-959b-cd96e9b89fb5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6f56ae76-1918-43f7-89a3-77b983b8bb29"}}}]}, {"uuid": "9e3f743f-e24d-486d-85ae-927080312cd0", "name": "load_p1rlv37732_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d998a0-628e-4009-a6c8-07af906f6d43"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b364fae8-133e-49f4-b5a3-761aad2becc9"}}}}, {"uuid": "ebe3272a-9772-4c74-876b-eeca1b7cebc0", "name": "6fecf92d-9e03-4f24-9d19-d5a6046488d2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2045141672666357, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3046267940472902, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cc9452be-8e52-4b91-96d8-092b3a3c5c39", "name": "ac7cf685-62c6-47f5-af2f-2c0d68dd981a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ebe3272a-9772-4c74-876b-eeca1b7cebc0"}}}]}, {"uuid": "f94b41ae-f7e2-45a9-8982-d1f2a4c17754", "name": "load_p1rlv37732_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d998a0-628e-4009-a6c8-07af906f6d43"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cc9452be-8e52-4b91-96d8-092b3a3c5c39"}}}}, {"uuid": "c2393e52-03c1-41ff-a32e-c1ac1d17ba93", "name": "776d405b-dd5a-49ab-aeea-98dcac4f6649_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.106965589535082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4202201192794711, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2ee241d8-7db3-4353-858e-63fdc838be4d", "name": "14dad654-46fe-471d-ad8d-bbf20a170c22", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c2393e52-03c1-41ff-a32e-c1ac1d17ba93"}}}]}, {"uuid": "15228525-13a8-4f68-9e9a-afeb20048a91", "name": "load_p1rlv37776_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b24da1e-9a6e-4545-9ad4-a9f0e9675fd1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2ee241d8-7db3-4353-858e-63fdc838be4d"}}}}, {"uuid": "a0ed8fb5-9e42-4c0e-873b-cf78be7f20be", "name": "372a9612-a533-4703-8742-e10f26fd3696_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.106965589535082, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4202201192794711, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e80daaf8-3d12-4628-8de2-e4372eedada7", "name": "121fa53a-e7f5-4720-8f34-227d39a96dd8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a0ed8fb5-9e42-4c0e-873b-cf78be7f20be"}}}]}, {"uuid": "306bb777-27dc-416c-96b8-0447cad5164d", "name": "load_p1rlv37776_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b24da1e-9a6e-4545-9ad4-a9f0e9675fd1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e80daaf8-3d12-4628-8de2-e4372eedada7"}}}}, {"uuid": "d93d7ca7-c729-4125-bfd0-2f82fa5a471f", "name": "9fd20af8-340a-405a-9370-74c501099235_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2167250892906645, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5534364726692191, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "734a6bb3-dae1-4e22-be5d-527c73a6540a", "name": "2b66fee4-6134-478a-b846-d39ac761d1b5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d93d7ca7-c729-4125-bfd0-2f82fa5a471f"}}}]}, {"uuid": "a68c442d-21fb-41e6-95df-690b8cd20ab7", "name": "load_p1rlv37778_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5aaed5d-8312-4707-a047-634e433bf49f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "734a6bb3-dae1-4e22-be5d-527c73a6540a"}}}}, {"uuid": "139fc5dd-4ca9-4a4e-82e3-8b80b42bb469", "name": "9c3a510f-8e0a-4448-bc99-f8bae25c5d9f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.2167250892906645, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5534364726692191, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "86030c64-9459-40d0-b8e1-71d5ae1714d0", "name": "924ac7c7-beb4-4989-b768-0880dcd98530", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "139fc5dd-4ca9-4a4e-82e3-8b80b42bb469"}}}]}, {"uuid": "e486422a-1d43-4a96-bc12-12ab56910f1a", "name": "load_p1rlv37778_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5aaed5d-8312-4707-a047-634e433bf49f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "86030c64-9459-40d0-b8e1-71d5ae1714d0"}}}}, {"uuid": "74ee0370-3552-4051-b115-3d9a4a803ca9", "name": "1d4e7e8d-41c6-4b7c-9fe1-c52d8786e85b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.902887215219663, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.111231385342157, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4bb58eb7-9b1b-49ed-be9f-dd90df587a32", "name": "5255aa2d-5cfc-4751-b610-3faf2f23d324", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "74ee0370-3552-4051-b115-3d9a4a803ca9"}}}]}, {"uuid": "d440d345-0229-4755-b7a7-bd7e8c8d8d62", "name": "load_p1rlv37782_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d7181ee-ef64-4ded-b619-00ac09d55bf5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4bb58eb7-9b1b-49ed-be9f-dd90df587a32"}}}}, {"uuid": "2f33d06a-54a0-48c0-bfcf-aec8a3f39520", "name": "45c722ba-3606-42aa-801a-02dbe9f10be2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.902887215219663, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.111231385342157, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "35d7c016-72d7-473e-b225-83d5a38ed0ad", "name": "086f70d3-b36c-4f63-bbbd-4ecc9a894bab", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2f33d06a-54a0-48c0-bfcf-aec8a3f39520"}}}]}, {"uuid": "5c8f4d9e-dd5b-4d8a-be06-f85681e95b9d", "name": "load_p1rlv37782_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d7181ee-ef64-4ded-b619-00ac09d55bf5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "35d7c016-72d7-473e-b225-83d5a38ed0ad"}}}}, {"uuid": "0e1bf61f-7a87-4871-aa7b-22c7e79ee653", "name": "79649c1e-e16e-4278-89ec-21d847472dda_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9179777962446224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3481400399277513, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a2723ae6-1a19-4f11-bd92-98787ee42be2", "name": "5d77a13a-856c-45bf-8e0f-19b712c6e3a3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0e1bf61f-7a87-4871-aa7b-22c7e79ee653"}}}]}, {"uuid": "8d154921-728c-48a5-b4a7-bcc8c97708bb", "name": "load_p1rlv38046_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10be49a0-301a-4c7e-8ab7-49c14e483079"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a2723ae6-1a19-4f11-bd92-98787ee42be2"}}}}, {"uuid": "ed625f7a-68a1-410e-b8df-84452f66f6b8", "name": "59123853-e958-47af-b720-f91604eef741_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9179777962446224, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3481400399277513, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8faee505-53f5-47af-9023-87d9ff1df03b", "name": "9eef8f72-c435-49be-afdb-c937371c9361", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ed625f7a-68a1-410e-b8df-84452f66f6b8"}}}]}, {"uuid": "4af84904-a5e3-4004-9f0c-6ed1b7231689", "name": "load_p1rlv38046_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10be49a0-301a-4c7e-8ab7-49c14e483079"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8faee505-53f5-47af-9023-87d9ff1df03b"}}}}, {"uuid": "1df809e0-3274-4384-9c54-d21577f02b53", "name": "4938b5d6-73b1-485a-9b79-9c1f12c4f1a8_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.567401274738218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6497123013243786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5b46ccb1-8f48-4fbc-9c82-e415a0ad9d07", "name": "42eb82be-9e48-4f8c-b18a-eeadcad25a56", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1df809e0-3274-4384-9c54-d21577f02b53"}}}]}, {"uuid": "dfde6f3a-b403-417f-8c61-c644f709f0d3", "name": "load_p1rlv38047_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0935a86b-b9fb-4058-8381-a41f67d6c9dd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5b46ccb1-8f48-4fbc-9c82-e415a0ad9d07"}}}}, {"uuid": "f5f4bd81-a812-4107-ac47-065bed44c722", "name": "fc72493e-0be6-4f75-9cb3-001f243338b0_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.567401274738218, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6497123013243786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7aee0163-ee99-4c05-95b5-44654457a3cc", "name": "f08bd294-0d21-416b-8f98-1b1cc7cdc5a7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f5f4bd81-a812-4107-ac47-065bed44c722"}}}]}, {"uuid": "f4651df5-82c7-4ab0-bd4e-5137e3353b1f", "name": "load_p1rlv38047_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0935a86b-b9fb-4058-8381-a41f67d6c9dd"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7aee0163-ee99-4c05-95b5-44654457a3cc"}}}}, {"uuid": "a01cc709-6a93-436c-be8f-404385b978ed", "name": "0341cac6-411d-407b-bb85-f0594adc83fc_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7055277650263714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24030088917661724, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "57c21e44-3c60-41c7-bf81-b13fffe7fa16", "name": "cf4d6a99-9857-443c-99c3-64407ec0a059", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a01cc709-6a93-436c-be8f-404385b978ed"}}}]}, {"uuid": "bdfa7b18-fee2-4bf2-9188-13278de4f43f", "name": "load_p1rlv38048_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5da7ff68-5f4c-4d56-88fc-7736df03c0bf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "57c21e44-3c60-41c7-bf81-b13fffe7fa16"}}}}, {"uuid": "f1942386-e836-4587-bcf8-0c1144583744", "name": "896c9f6e-9acb-4270-a40c-35a23d98683d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7055277650263714, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24030088917661724, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4227af12-679c-41e9-9c94-3eed1c08f7c6", "name": "a47147a2-c190-4c6e-985d-d08f6c5a3735", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f1942386-e836-4587-bcf8-0c1144583744"}}}]}, {"uuid": "e924c390-81b4-455c-9168-e1bd8492dbef", "name": "load_p1rlv38048_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5da7ff68-5f4c-4d56-88fc-7736df03c0bf"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4227af12-679c-41e9-9c94-3eed1c08f7c6"}}}}, {"uuid": "2c6e618c-9bd8-4a23-907b-e1b1054dc113", "name": "45e67a46-945d-46bc-a0e1-2da48c439ab3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3461402320099836, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.810674183062217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4a1be0c9-b577-4e0b-af32-43b02a73f6c3", "name": "71d6dfc0-198c-4a85-bcd4-d01618dd45d9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2c6e618c-9bd8-4a23-907b-e1b1054dc113"}}}]}, {"uuid": "1ad5c597-4a47-4353-9489-946f00e9c421", "name": "load_p1rlv38050_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cafc6c03-240d-499d-a3d8-983b554dd007"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4a1be0c9-b577-4e0b-af32-43b02a73f6c3"}}}}, {"uuid": "f4508784-7f40-4dc9-ad9d-315d99b5c956", "name": "2d00b450-e4c5-4f89-b86e-a120c04dcc5c_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3461402320099836, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.810674183062217, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "302ac0e1-a6d5-4edc-9313-27fe87f5939b", "name": "9dd76531-cda9-4ed8-a169-0315ae4c992e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f4508784-7f40-4dc9-ad9d-315d99b5c956"}}}]}, {"uuid": "cf8abd4e-54cb-4645-9afe-f58ba3325547", "name": "load_p1rlv38050_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cafc6c03-240d-499d-a3d8-983b554dd007"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "302ac0e1-a6d5-4edc-9313-27fe87f5939b"}}}}, {"uuid": "2db1953f-8ac5-4836-9b25-02934a423246", "name": "3fefc103-bd15-49d7-87e5-56ada79cf4ce_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5229589832640044, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3359880712066463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3a6e37bd-3209-44ad-9074-aa81b0812b1d", "name": "324d4778-60b7-42fc-9066-ef23bde6e01f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2db1953f-8ac5-4836-9b25-02934a423246"}}}]}, {"uuid": "14f17525-bfe4-475a-a678-6316279102a6", "name": "load_p1rlv38052_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9db6122d-1e51-46ac-9cea-ac436e189cd8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3a6e37bd-3209-44ad-9074-aa81b0812b1d"}}}}, {"uuid": "00387573-1e1f-4645-9f4f-ec988a7e403d", "name": "fc70e151-175c-4ed3-b3d0-797ba65b6651_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5229589832640044, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3359880712066463, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7df7a2f1-c087-4459-b464-df267e33d2ac", "name": "0170b546-2ac5-4288-bcaf-bbd96c66050c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "00387573-1e1f-4645-9f4f-ec988a7e403d"}}}]}, {"uuid": "aa000fe1-41ac-4646-98a4-d4d129240649", "name": "load_p1rlv38052_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9db6122d-1e51-46ac-9cea-ac436e189cd8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7df7a2f1-c087-4459-b464-df267e33d2ac"}}}}, {"uuid": "ddba05ec-071b-41c5-8bb7-5c3b8a924a32", "name": "4d7fe478-3369-4513-8f00-61cbffbd24de_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6912886909314806, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4972799611827758, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "49edfd08-7cb8-48ad-97ae-f3c8d7f24eae", "name": "069b9506-9dda-4954-a57a-b0e605bcff0b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ddba05ec-071b-41c5-8bb7-5c3b8a924a32"}}}]}, {"uuid": "37ee0175-44d4-4a8b-b904-22f3be239243", "name": "load_p1rlv38414_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a25b3511-86cf-404e-944f-273d3f94c05a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "49edfd08-7cb8-48ad-97ae-f3c8d7f24eae"}}}}, {"uuid": "72dc9b8f-422e-469c-8384-57ec67ffd3dd", "name": "178b63c7-ed29-45ce-b987-87d42a938880_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6912886909314806, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4972799611827758, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e05fa500-dcfe-4eb0-a404-e10a89b8bfb5", "name": "8f8ed8fa-059c-467b-919c-368f708c9254", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "72dc9b8f-422e-469c-8384-57ec67ffd3dd"}}}]}, {"uuid": "03aafef1-9f4a-40c0-ab85-7f1c8f3ca2d4", "name": "load_p1rlv38414_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a25b3511-86cf-404e-944f-273d3f94c05a"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e05fa500-dcfe-4eb0-a404-e10a89b8bfb5"}}}}, {"uuid": "922dde16-f073-4cba-89cd-a40353cca45c", "name": "ebf5b4b2-e731-4331-be5b-f322820089ad_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6878718453957338, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9600190343762964, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8cebfff3-32a0-4c4c-a852-dfa1f641987d", "name": "bda622e7-45b3-4ff7-867c-481d3a79b9c2", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "922dde16-f073-4cba-89cd-a40353cca45c"}}}]}, {"uuid": "51a15ddd-7db2-4da1-a796-936153825f09", "name": "load_p1rlv38417_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "201112bb-3dc7-4a15-9af6-155626ac1ae5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8cebfff3-32a0-4c4c-a852-dfa1f641987d"}}}}, {"uuid": "2c8a9662-1226-4af2-aecf-f8cd908d8f43", "name": "22ef792c-56e0-4d18-9df7-f59e6a870b97_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.6878718453957338, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9600190343762964, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1605947c-01ca-43fe-af9e-54f7a5d541dc", "name": "26506bde-e643-4406-af63-c70ff8a8c062", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2c8a9662-1226-4af2-aecf-f8cd908d8f43"}}}]}, {"uuid": "e24cf5b6-9e5c-424f-9d57-f2710d51ee80", "name": "load_p1rlv38417_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "201112bb-3dc7-4a15-9af6-155626ac1ae5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1605947c-01ca-43fe-af9e-54f7a5d541dc"}}}}, {"uuid": "40bee9c3-6f8e-4820-9b82-c561e4dd8cd5", "name": "b3e8f28b-546c-4b70-ae2f-cbfd56534bb2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1e9537dc-a42d-4f9d-82f4-d287f4a35c2f", "name": "d1e6d7cd-2d4c-443f-a229-feddf0d9f0f7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "40bee9c3-6f8e-4820-9b82-c561e4dd8cd5"}}}]}, {"uuid": "00fe2b7b-033a-492a-8759-3b3af439d698", "name": "load_p1rlv38419_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6e4595c-0ad9-4501-b86f-c559917d4b86"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1e9537dc-a42d-4f9d-82f4-d287f4a35c2f"}}}}, {"uuid": "4b9d5d48-e313-4aaa-b53d-24fccd78187f", "name": "a2179bea-f33a-48c1-bc9f-61ae16e84437_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3067870545822593, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7187638131848453, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6e0f2455-0479-4f0c-a49f-27a274acd027", "name": "e69754bc-3284-4f21-aca4-5b9887bc5486", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4b9d5d48-e313-4aaa-b53d-24fccd78187f"}}}]}, {"uuid": "679b326d-63be-4613-8983-a59fc0fa4c32", "name": "load_p1rlv38419_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6e4595c-0ad9-4501-b86f-c559917d4b86"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6e0f2455-0479-4f0c-a49f-27a274acd027"}}}}, {"uuid": "5e332f41-3784-41b1-bdd5-1b456b231b94", "name": "223ee756-b983-49a0-a8d7-5da73d7a9854_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4437884187508536, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6647073432497462, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "08881b61-ad46-4516-8ea2-fd49b9927b0d", "name": "207cf4ad-47c0-4517-9b0a-4cff9241790a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5e332f41-3784-41b1-bdd5-1b456b231b94"}}}]}, {"uuid": "8e95af66-31ca-450a-9aca-8e106892bc76", "name": "load_p1rlv38535_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0764c32-4f46-473a-9a72-cccc45ae28d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "08881b61-ad46-4516-8ea2-fd49b9927b0d"}}}}, {"uuid": "f31c8764-bc97-4b4f-9cde-1bff89246fc5", "name": "9a7854f0-9599-41e2-9500-3224aa894639_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.4437884187508536, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6647073432497462, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ca22f49a-9bb5-4730-9763-f1547662a06c", "name": "31ed3613-f5be-4a5d-8fd7-4c68c8981c8f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f31c8764-bc97-4b4f-9cde-1bff89246fc5"}}}]}, {"uuid": "58393dd1-90b2-4398-bbe7-3f69c8f25e00", "name": "load_p1rlv38535_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0764c32-4f46-473a-9a72-cccc45ae28d7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "ca22f49a-9bb5-4730-9763-f1547662a06c"}}}}, {"uuid": "d454f0ed-1569-430e-a940-9d11311f731b", "name": "f04f697d-37ba-4d73-95d1-f96a5f7ecc37_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5614762943111877, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5370528430833497, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d0dc1e81-ba82-445e-b840-c4eb3368537d", "name": "65336003-5aff-4e73-9c30-20dfe7f3ad78", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d454f0ed-1569-430e-a940-9d11311f731b"}}}]}, {"uuid": "d8642f17-a073-4fc4-b101-e1bde0153ea3", "name": "load_p1rlv38536_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ff930f9-63f0-4cab-b74a-3db7eb99f9eb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d0dc1e81-ba82-445e-b840-c4eb3368537d"}}}}, {"uuid": "5f99d8e8-222c-428c-b58d-bedefaed8cff", "name": "34fb25d7-73ca-40bd-a16e-924046d35039_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.5614762943111877, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5370528430833497, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "7717126d-86db-447c-b9ee-e99387684c27", "name": "7a840a3c-59e7-403f-850b-0ed4f56e8cda", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5f99d8e8-222c-428c-b58d-bedefaed8cff"}}}]}, {"uuid": "f132d970-074f-4152-9cf2-133e45e0e521", "name": "load_p1rlv38536_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ff930f9-63f0-4cab-b74a-3db7eb99f9eb"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "7717126d-86db-447c-b9ee-e99387684c27"}}}}, {"uuid": "70674b72-a9af-4244-a49c-a946d23cd5d4", "name": "bceb8436-c19d-430a-8583-8e705606fc45_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.025577912376512, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6479907691217454, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4b2e37ea-aabf-48dc-8e2b-7f18d626f96c", "name": "e3309c21-0a36-47e8-86bb-7cc362d97460", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "70674b72-a9af-4244-a49c-a946d23cd5d4"}}}]}, {"uuid": "80296163-decf-4c33-9c29-f346c1e8894b", "name": "load_p1rlv38638_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a3851f7-2dd3-447b-918f-7a8c954f21d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4b2e37ea-aabf-48dc-8e2b-7f18d626f96c"}}}}, {"uuid": "5f88a3fa-aabe-40f5-98e8-b4c86b5127f2", "name": "14f0875b-323b-4763-accf-cc6bcf457c6a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.025577912376512, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6479907691217454, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "821814a0-8f88-41d6-833d-160deb4cc4d3", "name": "ecc2ace6-5ab0-40de-9f3b-4ca05e791e59", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5f88a3fa-aabe-40f5-98e8-b4c86b5127f2"}}}]}, {"uuid": "23e8e6e7-c753-4b47-b081-311d3606c52a", "name": "load_p1rlv38638_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a3851f7-2dd3-447b-918f-7a8c954f21d1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "821814a0-8f88-41d6-833d-160deb4cc4d3"}}}}, {"uuid": "e0395ca4-5b57-46fa-a42b-a3439c90eed9", "name": "6be7f68a-6e69-4489-b82d-f3b9a8918363_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9441129975170507, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3957038740694923, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f9262875-977b-478e-9cf8-77465f491ce9", "name": "6be7f68a-6e69-4489-b82d-f3b9a8918363_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9441129975170507, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3957038740694923, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8ff257d5-f8f4-44d2-bef4-ea55e776524c", "name": "6be7f68a-6e69-4489-b82d-f3b9a8918363_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.9441129975170507, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3957038740694923, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "636fdd99-94b2-4fd8-92ef-dd9197f93ae7", "name": "e70df2d2-9cd0-4d1a-944e-4f0ab30a0962", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "e0395ca4-5b57-46fa-a42b-a3439c90eed9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f9262875-977b-478e-9cf8-77465f491ce9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "8ff257d5-f8f4-44d2-bef4-ea55e776524c"}}}]}, {"uuid": "e184e575-2f3d-45e6-be66-31e4057bd428", "name": "load_p1rlv12518", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72f659b6-d302-4887-a2f6-1a477ad3324c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "636fdd99-94b2-4fd8-92ef-dd9197f93ae7"}}}}, {"uuid": "c5214aa9-c215-401b-9460-cc4c162c5548", "name": "b3583558-bd86-450e-bf77-a42b5aedf621_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3777678420633588, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24446119545004893, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "0735b653-7b01-4570-a36e-ceb8ba68e689", "name": "b3583558-bd86-450e-bf77-a42b5aedf621_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3777678420633588, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24446119545004893, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ea3aef81-1188-4650-b68c-5f1a6b83a171", "name": "b3583558-bd86-450e-bf77-a42b5aedf621_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.3777678420633588, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24446119545004893, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "afe2c2f2-60ae-474a-84c9-2fb36790d4c8", "name": "26e5f4ef-16f1-46f8-9a3e-9b9ceea7fc24", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c5214aa9-c215-401b-9460-cc4c162c5548"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0735b653-7b01-4570-a36e-ceb8ba68e689"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ea3aef81-1188-4650-b68c-5f1a6b83a171"}}}]}, {"uuid": "f2fb4ebc-698b-4e4f-81b1-6f918e58f23b", "name": "load_p1rlv12528", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9660b80-0fce-4be4-b541-743d5811133c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "afe2c2f2-60ae-474a-84c9-2fb36790d4c8"}}}}, {"uuid": "d799aa9a-afa6-40bc-be59-538d75cef5f6", "name": "e4ebfcf1-30b4-48e9-846b-9c02955861b4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5605855582192873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.02826560468920274, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b12c6d01-4460-4311-a904-c5d13143e75b", "name": "e4ebfcf1-30b4-48e9-846b-9c02955861b4_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5605855582192873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.02826560468920274, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "37ef4d0b-b249-4220-a095-69f148aae9ad", "name": "e4ebfcf1-30b4-48e9-846b-9c02955861b4_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.5605855582192873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.02826560468920274, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e482f27d-250f-4b0d-8721-098972b804e9", "name": "ca91ac77-bba4-4c41-bf16-c13e29e3f08d", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d799aa9a-afa6-40bc-be59-538d75cef5f6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b12c6d01-4460-4311-a904-c5d13143e75b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "37ef4d0b-b249-4220-a095-69f148aae9ad"}}}]}, {"uuid": "c339ffc7-6711-43e4-a6ff-fd769736859f", "name": "load_p1rlv12534", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8796d817-aad6-4d22-b3d4-baf8a686c9df"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e482f27d-250f-4b0d-8721-098972b804e9"}}}}, {"uuid": "a89241f1-f525-4741-95f7-15ebe25f2bf7", "name": "ef38231c-6604-44b3-8ec3-f055074b9f60_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.424752506471074, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.0314252036301887, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "908dbfa2-35f6-4640-9846-29f2d49780b9", "name": "ef38231c-6604-44b3-8ec3-f055074b9f60_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.424752506471074, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.0314252036301887, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "777d5c0c-a10b-4048-97cf-3f3b8987e260", "name": "ef38231c-6604-44b3-8ec3-f055074b9f60_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.424752506471074, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 2.0314252036301887, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "980ad2f3-5855-4bdc-a897-8daa2e64c474", "name": "136af5b7-a726-451f-900a-e124c28ab761", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a89241f1-f525-4741-95f7-15ebe25f2bf7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "908dbfa2-35f6-4640-9846-29f2d49780b9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "777d5c0c-a10b-4048-97cf-3f3b8987e260"}}}]}, {"uuid": "a74387f0-d972-424b-a0e5-b02d4661ba19", "name": "load_p1rlv12536", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e89452f3-ce44-46d3-a259-f66044e01c2c"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "980ad2f3-5855-4bdc-a897-8daa2e64c474"}}}}, {"uuid": "9fa1b332-67ae-4b1c-b3e6-f7a01d4f4309", "name": "e72d8412-519c-4c9b-91b4-d30cabeed95e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0622945809345516, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23624651294541713, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "29f0f8e2-d893-4275-8fee-fc83bc3daa0f", "name": "e72d8412-519c-4c9b-91b4-d30cabeed95e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0622945809345516, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23624651294541713, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c5aa709c-3d6e-4efe-be9c-b404f5629251", "name": "e72d8412-519c-4c9b-91b4-d30cabeed95e_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.0622945809345516, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.23624651294541713, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5629edce-626f-4f5b-b520-c93cfdc3cc70", "name": "3e0e46c7-cb9f-493c-aa0d-20896a8d1c74", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9fa1b332-67ae-4b1c-b3e6-f7a01d4f4309"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "29f0f8e2-d893-4275-8fee-fc83bc3daa0f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c5aa709c-3d6e-4efe-be9c-b404f5629251"}}}]}, {"uuid": "930c0be3-c6a4-412b-beaf-86f6ec4e901e", "name": "load_p1rlv12985", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df3aae83-f4b0-4db2-9301-dff1664ac23e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5629edce-626f-4f5b-b520-c93cfdc3cc70"}}}}, {"uuid": "ddcd9421-d4d4-4ef3-9f27-f7b5eb64edb3", "name": "24b8b12b-5d1b-46af-a09c-026c4839e859_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.23597191427304684, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09897102743265196, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "379f3f51-cca1-443a-a710-48a9a2856435", "name": "24b8b12b-5d1b-46af-a09c-026c4839e859_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.23597191427304684, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09897102743265196, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ca194c22-8ad4-4093-9b0a-df28ce7dc6d2", "name": "24b8b12b-5d1b-46af-a09c-026c4839e859_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.23597191427304684, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.09897102743265196, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8cbaefc5-2d8b-49c8-9e44-885cf1424ae4", "name": "d9bbcea0-08b6-43e9-a41d-40b6878a1638", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ddcd9421-d4d4-4ef3-9f27-f7b5eb64edb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "379f3f51-cca1-443a-a710-48a9a2856435"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ca194c22-8ad4-4093-9b0a-df28ce7dc6d2"}}}]}, {"uuid": "d5cde358-4af8-4e17-9e0a-74099ddb837c", "name": "load_p1rlv16411", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ed6276c-a57b-40be-a1f1-34aaaba0ac28"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8cbaefc5-2d8b-49c8-9e44-885cf1424ae4"}}}}, {"uuid": "75af38b7-bb56-4c47-8f76-f921a8286af9", "name": "77502651-0c93-4d82-9ec9-c1e25cf5e25a_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7828407995320632, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7683556122374539, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "547c1fb1-1e21-43de-9124-e75a72e23d31", "name": "77502651-0c93-4d82-9ec9-c1e25cf5e25a_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7828407995320632, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7683556122374539, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6a9f4749-ed1a-46fc-8dfa-46c60b940f65", "name": "77502651-0c93-4d82-9ec9-c1e25cf5e25a_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.7828407995320632, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7683556122374539, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "90cea8c6-e1fc-4a53-9a62-fbb951d13dc3", "name": "c35e4979-a43e-4803-a90a-5d57dbc220f7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "75af38b7-bb56-4c47-8f76-f921a8286af9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "547c1fb1-1e21-43de-9124-e75a72e23d31"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6a9f4749-ed1a-46fc-8dfa-46c60b940f65"}}}]}, {"uuid": "92d8cb69-f945-46f1-8d83-82c2569dbeb0", "name": "load_p1rlv18169", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c1eac45-623a-4f0a-874d-a4b56a8e2ea7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "90cea8c6-e1fc-4a53-9a62-fbb951d13dc3"}}}}, {"uuid": "75109933-e360-431a-ae56-6a8713fb4e4f", "name": "0c352d6e-62c5-4ca5-aa5f-694c59a9bde2_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7765583938143562, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2953468263898592, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "52932e4b-3f68-4d39-9cdf-6831b48e90a2", "name": "0c352d6e-62c5-4ca5-aa5f-694c59a9bde2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7765583938143562, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2953468263898592, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "ce695ebd-ff35-4c4e-8193-4b63fcbae6ad", "name": "0c352d6e-62c5-4ca5-aa5f-694c59a9bde2_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.7765583938143562, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2953468263898592, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fa9731e1-8866-4fab-8d71-5c264f3aa4a3", "name": "ceabf2fd-a4fe-49a3-b040-998bc449584e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "75109933-e360-431a-ae56-6a8713fb4e4f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "52932e4b-3f68-4d39-9cdf-6831b48e90a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ce695ebd-ff35-4c4e-8193-4b63fcbae6ad"}}}]}, {"uuid": "7a8af673-1f29-42b4-bdc1-b854078775d7", "name": "load_p1rlv18194", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "949f4cce-f321-4bf0-830b-489edc9964c7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fa9731e1-8866-4fab-8d71-5c264f3aa4a3"}}}}, {"uuid": "9387af20-49dd-475f-8324-8380a627105a", "name": "f3505cd8-102f-4866-a8e6-83220722e696_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3791309816618758, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4243669985282459, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "68b9e4ad-9706-461f-a964-bdf6fbec6b39", "name": "f3505cd8-102f-4866-a8e6-83220722e696_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3791309816618758, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4243669985282459, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5767b6a3-e20f-4fb6-b4e9-f280bf9623f1", "name": "f3505cd8-102f-4866-a8e6-83220722e696_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.3791309816618758, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4243669985282459, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c78d81df-08be-4abd-8543-ba1e3bc71ced", "name": "540ed8e3-c387-4cc6-a726-b7aa52ff1f02", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9387af20-49dd-475f-8324-8380a627105a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "68b9e4ad-9706-461f-a964-bdf6fbec6b39"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5767b6a3-e20f-4fb6-b4e9-f280bf9623f1"}}}]}, {"uuid": "92845255-cba9-4f50-9388-b5806893844f", "name": "load_p1rlv18201", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ead37cb8-af1e-4a46-9466-6ff298b7f8b7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c78d81df-08be-4abd-8543-ba1e3bc71ced"}}}}, {"uuid": "66e107e0-5a8d-442d-af88-d909e6806c1d", "name": "cfed4f37-a7eb-470e-9e6e-7429c56af142_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.969330641054165, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5731466084062546, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "788ad97c-109f-4389-8ab7-e5d1aa18711d", "name": "cfed4f37-a7eb-470e-9e6e-7429c56af142_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.969330641054165, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5731466084062546, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1a1efbec-cf76-4c1f-b9d1-8e1f4f40f85f", "name": "cfed4f37-a7eb-470e-9e6e-7429c56af142_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.969330641054165, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5731466084062546, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eb130b96-b1a6-4ad9-92bb-f7c950649d87", "name": "bb4f4ca4-46cc-4d38-974c-bdc47816551a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "66e107e0-5a8d-442d-af88-d909e6806c1d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "788ad97c-109f-4389-8ab7-e5d1aa18711d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "1a1efbec-cf76-4c1f-b9d1-8e1f4f40f85f"}}}]}, {"uuid": "1d20a067-0c6f-4dd1-96ae-00fbe68df8be", "name": "load_p1rlv20414", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0a92e79-0ca2-4a10-9050-9e8d7442b019"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eb130b96-b1a6-4ad9-92bb-f7c950649d87"}}}}, {"uuid": "c3167d2e-7abd-4ec9-b7db-189aa1ce6350", "name": "d7a5cbb2-952d-451b-a9c5-797b0d94e7f3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.231046440619022, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3410918425021952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "82f1e837-f7ff-45a7-99cd-9947a49f530b", "name": "d7a5cbb2-952d-451b-a9c5-797b0d94e7f3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.231046440619022, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3410918425021952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b62f9ca8-ad3c-458e-8c6c-329a36d278d6", "name": "d7a5cbb2-952d-451b-a9c5-797b0d94e7f3_3", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.231046440619022, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3410918425021952, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "80fd6578-bbee-4566-9069-5278cad9984b", "name": "d76b08ad-4f91-4cda-9fc7-106a67597cb1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c3167d2e-7abd-4ec9-b7db-189aa1ce6350"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "82f1e837-f7ff-45a7-99cd-9947a49f530b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b62f9ca8-ad3c-458e-8c6c-329a36d278d6"}}}]}, {"uuid": "0f1e4fed-f27c-407f-bb1b-0a713223b7c4", "name": "load_p1rlv20501", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cebe1b53-cca6-4bd4-a9f0-616ffb9750b3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "80fd6578-bbee-4566-9069-5278cad9984b"}}}}, {"uuid": "d452202d-9209-43e3-9f1b-676ca771bf58", "name": "b438d550-9204-4deb-b624-2af3f3f95abf_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.718035027374153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.747804250682338, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e61ddcce-02b6-49db-8ac0-51d03bffec33", "name": "153d6d88-fe56-4daa-8fe9-2cc8ef339106", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d452202d-9209-43e3-9f1b-676ca771bf58"}}}]}, {"uuid": "742d6d8b-18ae-42cc-9249-c8f8e8f4f378", "name": "load_p1rlv183_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3df778b4-e60b-4e17-b24b-67742d090f42"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e61ddcce-02b6-49db-8ac0-51d03bffec33"}}}}, {"uuid": "50a6d660-3a31-481e-a6c6-f9690dbb7ca1", "name": "ea228642-f5c5-468e-a9dd-409a56d9f874_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.718035027374153, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.747804250682338, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "8bda7891-b82b-426f-b18c-5eb0fb925fd2", "name": "10d93e0c-b904-4504-aacd-b5f5838c6695", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "50a6d660-3a31-481e-a6c6-f9690dbb7ca1"}}}]}, {"uuid": "48054bdd-5552-4b5b-be40-7d539c24e9dd", "name": "load_p1rlv183_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3df778b4-e60b-4e17-b24b-67742d090f42"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "8bda7891-b82b-426f-b18c-5eb0fb925fd2"}}}}, {"uuid": "c2546b6f-fccd-47a4-b41a-52ade98419c7", "name": "a75381a0-7cd8-4979-84c6-33a9b055fcfa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.127855103696037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.9003395103499228, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4e801885-fc8b-44e6-8cff-8ca4ce49e685", "name": "4d068117-da86-4eb2-98b5-8795e125680a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c2546b6f-fccd-47a4-b41a-52ade98419c7"}}}]}, {"uuid": "c8e3ab78-fc66-4999-a4a3-9f6f6034ea51", "name": "load_p1rlv184_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42ca8327-5dcc-415a-820c-ef6ec038b3d8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4e801885-fc8b-44e6-8cff-8ca4ce49e685"}}}}, {"uuid": "66861fae-18d4-4b12-89f9-a42a505c43fe", "name": "f1233123-1f28-4f98-a380-9a86a8c78985_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.127855103696037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.9003395103499228, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "2c03d88e-748c-47a3-b381-2286aeb0abd2", "name": "6f60df77-8937-41d3-b043-9b28c08007c9", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "66861fae-18d4-4b12-89f9-a42a505c43fe"}}}]}, {"uuid": "db648879-6a88-469a-b3ad-bab23c777335", "name": "load_p1rlv184_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42ca8327-5dcc-415a-820c-ef6ec038b3d8"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "2c03d88e-748c-47a3-b381-2286aeb0abd2"}}}}, {"uuid": "344cdbb3-a80c-404d-9261-eab3f95c614f", "name": "9c4438d4-ff81-4106-afbc-33f8775b30ce_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.1997144025033135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.11221312599546865, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "83102fd9-ad7e-4a54-8f3b-de4b3131ce41", "name": "6e16813c-5d8c-4a79-810c-0c69e27021cc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "344cdbb3-a80c-404d-9261-eab3f95c614f"}}}]}, {"uuid": "958e832c-6fa1-49f6-b718-480453e9d335", "name": "load_p1rlv190_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33b6400e-c84e-43cf-b254-99f946e5a308"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "83102fd9-ad7e-4a54-8f3b-de4b3131ce41"}}}}, {"uuid": "51739107-d681-47db-a519-530a5d81e380", "name": "81398e9c-c69f-44f1-ae1f-52bf38236f43_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.1997144025033135, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.11221312599546865, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4ce391b4-aef8-4ab8-918f-0b278f46c29c", "name": "e6cd5f06-51c1-4e78-a54c-b363b90f918e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "51739107-d681-47db-a519-530a5d81e380"}}}]}, {"uuid": "f5fc5e6d-4a64-4320-b5f3-efa23416a9d2", "name": "load_p1rlv190_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33b6400e-c84e-43cf-b254-99f946e5a308"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4ce391b4-aef8-4ab8-918f-0b278f46c29c"}}}}, {"uuid": "f9119206-6129-4831-af07-d5ed4b642c85", "name": "e8661d29-1ea4-4741-ad74-bd78340ddd97_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.549201052937441, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.4274432384427707, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "71a46f8f-842d-4937-a801-10ae42b24e5f", "name": "6a3d3aef-865d-46e9-a960-161498a719fe", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f9119206-6129-4831-af07-d5ed4b642c85"}}}]}, {"uuid": "81c21836-45b0-4154-82ae-266770c938c2", "name": "load_p1rlv193_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84223c1b-69e4-4ebc-8274-8706bb412780"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "71a46f8f-842d-4937-a801-10ae42b24e5f"}}}}, {"uuid": "58f983e5-4e84-49bc-91b5-e3a89fdfa15b", "name": "c5f60dda-40d2-4501-b095-c3a416842481_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 5.549201052937441, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 3.4274432384427707, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "64473a35-4b5a-4b3b-9df1-622a7c2e80f0", "name": "6eb521f5-3493-4631-9d8e-09e4fdf20bb4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "58f983e5-4e84-49bc-91b5-e3a89fdfa15b"}}}]}, {"uuid": "30dac874-159f-460d-82b9-04974e73e308", "name": "load_p1rlv193_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84223c1b-69e4-4ebc-8274-8706bb412780"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "64473a35-4b5a-4b3b-9df1-622a7c2e80f0"}}}}, {"uuid": "a628d381-76e4-40cf-bc24-857e04147606", "name": "22ff9d9d-ac24-4905-9832-998eae8c6b4e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.052819039029729, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6406126314043256, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "45fd4d14-39df-4fa4-b612-a444a80083df", "name": "e5b3eba3-131f-4d1b-ac25-750cf0a4f239", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a628d381-76e4-40cf-bc24-857e04147606"}}}]}, {"uuid": "5557aa36-6bc2-494a-8072-27bd794500fb", "name": "load_p1rlv202_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "de2366e4-30da-429a-82b9-c0ef27eeab47"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "45fd4d14-39df-4fa4-b612-a444a80083df"}}}}, {"uuid": "23222d19-9d59-45d2-a78d-58fc93fd5c6a", "name": "73133d72-263e-4d0d-987b-43979afa5ec3_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 7.052819039029729, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6406126314043256, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "18272da0-9eb7-4022-ba19-f26531774504", "name": "51166873-b93f-4926-9e62-57215002bd49", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "23222d19-9d59-45d2-a78d-58fc93fd5c6a"}}}]}, {"uuid": "ce162529-8696-48ac-a532-4fcc622d5dcd", "name": "load_p1rlv202_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "de2366e4-30da-429a-82b9-c0ef27eeab47"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "18272da0-9eb7-4022-ba19-f26531774504"}}}}, {"uuid": "d11e80ed-46b6-44dd-afc2-5a36e25a5ea6", "name": "7b83fc9d-61ee-4397-8667-a8588c3bc7c9_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 10.312489622510887, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5278845211341558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "86764a50-118f-4ae0-904c-3eb7d9149897", "name": "a56124cc-b228-47df-b16e-25063ca6be04", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d11e80ed-46b6-44dd-afc2-5a36e25a5ea6"}}}]}, {"uuid": "a54e9ee0-d987-4d48-8ca7-d8104322c7c8", "name": "load_p1rlv204_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d663fcdc-6c67-4bc9-99ed-12439f75804f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "86764a50-118f-4ae0-904c-3eb7d9149897"}}}}, {"uuid": "57c0a953-1df6-4ccd-bc63-5a6de34ae501", "name": "48bffe9b-9342-4db0-9ae8-708b0d958dc6_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 10.312489622510887, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5278845211341558, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "99a56edd-9cc3-431a-8528-a4b629d07122", "name": "c8f70a44-fc85-4b43-84d4-1d98126976c7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "57c0a953-1df6-4ccd-bc63-5a6de34ae501"}}}]}, {"uuid": "f5df41fa-acf8-47b6-87fa-8f483834918a", "name": "load_p1rlv204_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d663fcdc-6c67-4bc9-99ed-12439f75804f"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "99a56edd-9cc3-431a-8528-a4b629d07122"}}}}, {"uuid": "63d5acfc-0745-4111-8177-dd66ae09918b", "name": "8d4d1bae-d8e2-4947-998e-f570b1a6b343_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9264329962341185, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3633013910451994, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "54707afb-12f1-4423-950c-81e7e8b8cb3d", "name": "461691a0-b77c-4154-a045-49dcb5767ddc", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "63d5acfc-0745-4111-8177-dd66ae09918b"}}}]}, {"uuid": "0db73d3b-1367-4883-92fb-b35b5fe61489", "name": "load_p1rlv206_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90aa0d14-285a-4468-bbde-8d76f65b1780"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "54707afb-12f1-4423-950c-81e7e8b8cb3d"}}}}, {"uuid": "cafb2fa3-b0e4-42e8-b518-09654adfe279", "name": "0cfa0843-e053-415d-9e17-f093387d41dc_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.9264329962341185, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 1.3633013910451994, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "9f52038c-27b1-4970-ae57-228257c9bf35", "name": "76c3855d-0b8d-4cb8-9027-5eb6091bd9a4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cafb2fa3-b0e4-42e8-b518-09654adfe279"}}}]}, {"uuid": "ab252666-2ea9-4e1c-aa7a-e49d13cad5fe", "name": "load_p1rlv206_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90aa0d14-285a-4468-bbde-8d76f65b1780"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "9f52038c-27b1-4970-ae57-228257c9bf35"}}}}, {"uuid": "0e86c524-7124-441d-8f10-66f45ed36a68", "name": "8ba30a99-87f5-446e-ace9-b55d7af9360b_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.495920496244223, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.518490967551786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "239be45a-d09b-44fb-9a2b-b33b6edd3876", "name": "6e0cfa39-9b52-47ac-87fe-e50f8b5afb6c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "0e86c524-7124-441d-8f10-66f45ed36a68"}}}]}, {"uuid": "dadd83f6-5ccf-4bac-ab6f-cae797485027", "name": "load_p1rlv207_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6627102c-4524-4e69-bb4d-5b93226df412"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "239be45a-d09b-44fb-9a2b-b33b6edd3876"}}}}, {"uuid": "9ab22791-181c-4d6f-9cc0-3b61593d3e1d", "name": "ffba4d1d-3ac4-4596-8520-a1ba07ae099e_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 11.495920496244223, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 4.518490967551786, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b22fe0e0-baee-4fe0-b605-ddd37c2ffc6a", "name": "4c32cfe6-8a80-42a6-8417-c3d18f08fcac", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9ab22791-181c-4d6f-9cc0-3b61593d3e1d"}}}]}, {"uuid": "4775bbae-5798-4601-a801-b706bf2c4ee6", "name": "load_p1rlv207_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6627102c-4524-4e69-bb4d-5b93226df412"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b22fe0e0-baee-4fe0-b605-ddd37c2ffc6a"}}}}, {"uuid": "cbc3c1e0-4de2-487d-9596-35203ed448d3", "name": "7f5018a1-d799-4607-bdb7-1808ad52c298_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.1298927880171155, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3569806362972607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "eb992e66-c752-4374-a1e0-6b6209cd65af", "name": "f42b3cc4-474a-4489-9d4b-4eec13d43e4b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cbc3c1e0-4de2-487d-9596-35203ed448d3"}}}]}, {"uuid": "925eea4e-1656-49bf-8ff1-d56eb17907ab", "name": "load_p1rlv212_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a982feac-5730-4fe0-a1b8-25c06b36e3b0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "eb992e66-c752-4374-a1e0-6b6209cd65af"}}}}, {"uuid": "4154954c-7a18-456b-8622-52f9c2893e7c", "name": "69490a8c-b272-46ef-a77f-31b698c067c7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 6.1298927880171155, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3569806362972607, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f0618bd8-742f-4511-a715-4b51b8f630cb", "name": "90e2596a-5f5a-4214-bd68-9ceaea0de7cf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4154954c-7a18-456b-8622-52f9c2893e7c"}}}]}, {"uuid": "82788e05-b8cc-4374-b70a-1b283d49b619", "name": "load_p1rlv212_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a982feac-5730-4fe0-a1b8-25c06b36e3b0"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f0618bd8-742f-4511-a715-4b51b8f630cb"}}}}, {"uuid": "d0f61b3d-9dd8-45cc-b426-9ef0aaac7c1b", "name": "d7e028a1-2a14-4d50-8030-c93bc7628a90_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.583696505537418, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4678810835686954, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "25f54090-d0d6-42d4-b9aa-0b3231c4361b", "name": "082a6d0f-4854-44e3-9719-141d16201519", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d0f61b3d-9dd8-45cc-b426-9ef0aaac7c1b"}}}]}, {"uuid": "0720a126-2cc3-4dc6-af38-58177f078903", "name": "load_p1rlv12687_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "163c3824-6847-4b94-9e81-08f15f4667a1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "25f54090-d0d6-42d4-b9aa-0b3231c4361b"}}}}, {"uuid": "4a209186-c2ca-47e3-91c2-43756ee9d9d1", "name": "eb25abe8-65f1-4081-a59a-54ed4be1f40b_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.583696505537418, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.4678810835686954, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5df58dd4-8b5e-4767-8d0b-014a76f208cc", "name": "0c67fd09-9f70-4278-b5c3-87ba4c32d4a4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "4a209186-c2ca-47e3-91c2-43756ee9d9d1"}}}]}, {"uuid": "587b7bd5-45c9-4d29-a103-1654b7609e31", "name": "load_p1rlv12687_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "163c3824-6847-4b94-9e81-08f15f4667a1"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5df58dd4-8b5e-4767-8d0b-014a76f208cc"}}}}, {"uuid": "7c9572f6-3d24-49ce-8e4b-bd40d675d2ff", "name": "24658cf7-3b72-4072-aa99-2aa43e79f68e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.073647835052278, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9870900939844905, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "78dc3bd2-faee-4bfa-a8ad-e73cef6d4bb8", "name": "10dbcd6c-c7d5-4021-8409-dbecd8397b67", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7c9572f6-3d24-49ce-8e4b-bd40d675d2ff"}}}]}, {"uuid": "acd5ef5c-b674-4b1a-bb31-a05b03cac46d", "name": "load_p1rlv12713_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff16aad0-98c1-4563-a844-e0ce909c1a79"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "78dc3bd2-faee-4bfa-a8ad-e73cef6d4bb8"}}}}, {"uuid": "6c8c64d5-8232-48f3-b779-e284a0d79625", "name": "2e710491-6935-4c22-a3fb-03a66154e627_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.073647835052278, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.9870900939844905, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f197177b-277e-4088-b0ad-e2d741d93d9f", "name": "b7ff3a42-4e19-4355-b425-f3c12537a70e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6c8c64d5-8232-48f3-b779-e284a0d79625"}}}]}, {"uuid": "3f3a20a9-a720-4b31-a158-a8d5a99ac7c5", "name": "load_p1rlv12713_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff16aad0-98c1-4563-a844-e0ce909c1a79"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f197177b-277e-4088-b0ad-e2d741d93d9f"}}}}, {"uuid": "f165255b-c573-44e3-84cd-49783a88ab2e", "name": "1dbad6e5-8c1a-4011-bea1-bff55d509e1c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.717517070184915, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6715744239051029, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "420a0bce-f51c-4b62-8e6b-9a387e86a735", "name": "b4b542a3-23bc-49fe-8b97-9061f3eb79d0", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "f165255b-c573-44e3-84cd-49783a88ab2e"}}}]}, {"uuid": "18ffffa2-9edd-4b1e-9e65-5b6c6bae3648", "name": "load_p1rlv17006_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b53edd15-5a3e-4b7a-97c4-046582bb4801"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "420a0bce-f51c-4b62-8e6b-9a387e86a735"}}}}, {"uuid": "3a246336-b14b-440f-bc6a-b422db5dbaf9", "name": "eb6052a5-cda9-4e21-bc34-c012cb2a45c9_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.717517070184915, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6715744239051029, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "daf286f3-ba08-4a4a-a63b-e2444b88c23b", "name": "34263f6f-fb33-4385-b0da-d5e94b1c7962", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "3a246336-b14b-440f-bc6a-b422db5dbaf9"}}}]}, {"uuid": "60052a5b-71bb-4bc8-8e08-ce9093d39625", "name": "load_p1rlv17006_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b53edd15-5a3e-4b7a-97c4-046582bb4801"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "daf286f3-ba08-4a4a-a63b-e2444b88c23b"}}}}, {"uuid": "7b15de94-09be-4c5d-bcad-51da9006d9b8", "name": "4e35b209-fd6d-4c40-8295-c4c03decf7ed_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.232057012168481, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2513317849586886, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a0b81f47-b2c7-481f-b0d6-0a682a1f9e12", "name": "1cd07c6b-4cb5-4c8c-894d-049edc6327bf", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b15de94-09be-4c5d-bcad-51da9006d9b8"}}}]}, {"uuid": "062e62cb-fef0-435f-8624-d1ce4dce2226", "name": "load_p1rlv17103_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ff9eb4c-2523-48e0-8490-619d26b9cca4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a0b81f47-b2c7-481f-b0d6-0a682a1f9e12"}}}}, {"uuid": "cf5c4bd5-036b-40d7-b817-cc747db47804", "name": "3052e4cd-e42c-46e4-a14f-22b6800c7106_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.232057012168481, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2513317849586886, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "fa3a0152-406c-41d9-823e-8e9d0c488cb3", "name": "7de8fa38-01f0-48ce-bd95-b70f4741c401", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "cf5c4bd5-036b-40d7-b817-cc747db47804"}}}]}, {"uuid": "97bbad00-72ba-4f7f-9c82-ae75e91ccf17", "name": "load_p1rlv17103_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ff9eb4c-2523-48e0-8490-619d26b9cca4"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "fa3a0152-406c-41d9-823e-8e9d0c488cb3"}}}}, {"uuid": "41fbaba5-530d-45c4-8ac2-003cdc444c4b", "name": "2e037faf-fd59-47a0-b8d8-baff8428d902_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2219087879829873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3595087789107823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "c00fb412-46d2-4e3b-b892-4c29ed9a96dc", "name": "34327e4c-a3bf-4a34-bb48-d1805c4c2b46", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "41fbaba5-530d-45c4-8ac2-003cdc444c4b"}}}]}, {"uuid": "94e1ce9a-0ea6-41c7-8acd-3c47597808c8", "name": "load_p1rlv17155_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3c6c52e-cf93-467a-a303-94b96b33a3da"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "c00fb412-46d2-4e3b-b892-4c29ed9a96dc"}}}}, {"uuid": "bcd3781d-68d3-49c8-98f2-5d2dfd72d02c", "name": "c24d5d86-507c-4da1-a740-cbfa6e9b70d8_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.2219087879829873, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3595087789107823, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "367d3fb3-38e1-46a9-afe8-6002ec634b34", "name": "096662e5-09d2-4d3f-83b8-7e5c0313d32b", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "bcd3781d-68d3-49c8-98f2-5d2dfd72d02c"}}}]}, {"uuid": "ea2204e5-c733-4c5d-9f57-f1ae7993930e", "name": "load_p1rlv17155_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3c6c52e-cf93-467a-a303-94b96b33a3da"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "367d3fb3-38e1-46a9-afe8-6002ec634b34"}}}}, {"uuid": "5ca29a6b-8871-4316-9614-9cdc26b525c3", "name": "b34ee401-7b3b-4bd1-aecd-b49dc4a423cd_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.942829069048031, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.025560880160820944, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "28234f8d-0f72-4591-a0e5-92555cccad67", "name": "26114456-b716-42bd-b5cd-0cb881ca3c1e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "5ca29a6b-8871-4316-9614-9cdc26b525c3"}}}]}, {"uuid": "3788a4d6-fb67-408b-a39a-382a54c99337", "name": "load_p1rlv17164_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "041caa30-2985-44ca-8013-e11a9bda7dff"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "28234f8d-0f72-4591-a0e5-92555cccad67"}}}}, {"uuid": "d1180f7a-4072-4682-9e72-f7710c39e782", "name": "1c5d76ca-3c9e-4297-a20f-bd64dbf176a2_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.942829069048031, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.025560880160820944, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "62763e78-f998-4c71-9591-66a454e2912d", "name": "3d73307b-f167-4794-a374-6943ca16307f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d1180f7a-4072-4682-9e72-f7710c39e782"}}}]}, {"uuid": "607dd42d-074f-451c-abe2-2be23e589cec", "name": "load_p1rlv17164_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "041caa30-2985-44ca-8013-e11a9bda7dff"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "62763e78-f998-4c71-9591-66a454e2912d"}}}}, {"uuid": "21a8d94a-5f88-43e9-86ad-5de85cc4c1bc", "name": "d6f25302-9bf5-4b6b-8109-772358bb7981_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.232057012168481, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2513317849586886, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d8ce9ad7-c027-48cb-8677-3e76b8508613", "name": "fc57ffc1-a1a5-4772-ab6c-285ce5f0b9be", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "21a8d94a-5f88-43e9-86ad-5de85cc4c1bc"}}}]}, {"uuid": "921af739-3a49-488e-b908-a755178667b5", "name": "load_p1rlv17167_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b4e44ab-e644-4e48-b1b2-82dc15d38d17"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d8ce9ad7-c027-48cb-8677-3e76b8508613"}}}}, {"uuid": "c95623eb-7e70-4230-89ec-95912a3b104e", "name": "870b8ada-fd08-4206-9fc5-01346c9ff362_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.232057012168481, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.2513317849586886, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "1ce786d2-8a25-4b49-a086-d96fa76a8d08", "name": "d75ae0f2-7d95-4690-b229-56fce3ab59ee", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c95623eb-7e70-4230-89ec-95912a3b104e"}}}]}, {"uuid": "b4f5139d-e8a9-4b09-81cc-226782639deb", "name": "load_p1rlv17167_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b4e44ab-e644-4e48-b1b2-82dc15d38d17"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "1ce786d2-8a25-4b49-a086-d96fa76a8d08"}}}}, {"uuid": "7446423d-82b3-4d10-bcf9-723674add925", "name": "d3372449-16d8-484a-a833-f29fb227400d_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9560799536695528, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.499516661128582, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6819cfd1-4ede-49bb-80b3-81faba8c4337", "name": "26394e59-96de-4fcd-bdf3-b8c99b381804", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7446423d-82b3-4d10-bcf9-723674add925"}}}]}, {"uuid": "a26b6799-9da9-46b0-974d-186fa2a110ef", "name": "load_p1rlv17199_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5768eaca-abe3-4347-af78-02b50ec6f2a9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6819cfd1-4ede-49bb-80b3-81faba8c4337"}}}}, {"uuid": "aec4bb52-4e0e-4666-b311-aff796a6e741", "name": "9fd2156c-d0a8-4aeb-a216-5711fc5b8345_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.9560799536695528, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.499516661128582, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6bbfcac3-e8d6-49b5-b0ed-56f508d367d2", "name": "0504995a-08d3-4acf-a5ec-f035fb0edd55", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "aec4bb52-4e0e-4666-b311-aff796a6e741"}}}]}, {"uuid": "f16ea12a-d96f-4c89-aae1-a9e2f73b498e", "name": "load_p1rlv17199_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5768eaca-abe3-4347-af78-02b50ec6f2a9"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6bbfcac3-e8d6-49b5-b0ed-56f508d367d2"}}}}, {"uuid": "9501db4f-4d34-46ab-b337-a9b58a0ecc04", "name": "c7920de9-9700-44da-88a2-baee1b71a3fa_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4651344294517608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7736313908316925, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3e397dca-c5aa-41b9-a651-a5594d57ce82", "name": "b3217784-6b6f-4cbb-ae04-0586946430b3", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "9501db4f-4d34-46ab-b337-a9b58a0ecc04"}}}]}, {"uuid": "486b1fa9-c97d-4d8f-8dd5-a12f4ed1f6a4", "name": "load_p1rlv17376_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c9970ae-e914-407d-8222-12c08638a854"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3e397dca-c5aa-41b9-a651-a5594d57ce82"}}}}, {"uuid": "d1c9d7de-ec26-4339-b074-a8feed5b6bd3", "name": "b9ef11a0-e24d-411d-9d2d-b1d7f910cbf7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 3.4651344294517608, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.7736313908316925, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "3f324903-fa8c-4c76-a937-15d2f343d5e4", "name": "365eec18-9d98-4ef6-a549-3c01f3c032ad", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "d1c9d7de-ec26-4339-b074-a8feed5b6bd3"}}}]}, {"uuid": "e074293a-eec0-4036-a797-8b60e105c83f", "name": "load_p1rlv17376_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c9970ae-e914-407d-8222-12c08638a854"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "3f324903-fa8c-4c76-a937-15d2f343d5e4"}}}}, {"uuid": "ead23219-08fe-44ab-820a-d0d14103563b", "name": "ba31d245-a5df-4e40-bd84-2537388de1de_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "f20bbd88-d644-4460-b91b-f7d7a0dd9c33", "name": "e7afd31e-cc94-4190-bd64-93c2978c75e8", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "ead23219-08fe-44ab-820a-d0d14103563b"}}}]}, {"uuid": "c7830443-55ae-4071-84cd-61cb658dfa1d", "name": "load_p1rlv17402_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc7fa312-1baf-4f23-925f-a281071183a6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "f20bbd88-d644-4460-b91b-f7d7a0dd9c33"}}}}, {"uuid": "c032abac-cd1f-4a1e-bbd5-d4802c4799f8", "name": "7aee58e6-4854-4da3-b1b6-cd96d079e46f_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.401267720054582, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6871659709761725, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d9b0b461-3686-46ed-a372-44fe942df55a", "name": "08b8a5f8-54ac-4bef-9a93-f060a37836e7", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c032abac-cd1f-4a1e-bbd5-d4802c4799f8"}}}]}, {"uuid": "c4c2d28d-64de-4aef-9b56-71b581140ea8", "name": "load_p1rlv17402_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc7fa312-1baf-4f23-925f-a281071183a6"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d9b0b461-3686-46ed-a372-44fe942df55a"}}}}, {"uuid": "c6d70775-0474-4758-9e2b-53a281b01f2b", "name": "951110b2-1b20-46ea-97ea-669c68971c74_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "cece30de-5748-49d0-95c9-04aae051c96b", "name": "934dfe2f-a3da-4353-ab7d-ff5cf4bd4aca", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "c6d70775-0474-4758-9e2b-53a281b01f2b"}}}]}, {"uuid": "4de72967-d0e0-4245-a2c9-90ed95c634db", "name": "load_p1rlv17413_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f147f7e5-33e8-430b-9822-715e772debb3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "cece30de-5748-49d0-95c9-04aae051c96b"}}}}, {"uuid": "410be76a-d3e6-4fe5-8234-da21b56ab803", "name": "86f67b91-abe0-4707-b5b7-1fc268250b03_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.0191431035669187, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.3818764773978318, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "a1f185f9-ed32-4e4d-8ab5-4cb30f46e1fa", "name": "be5f5a1e-d7c2-4cc0-b2ec-ebb2f4d99001", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "410be76a-d3e6-4fe5-8234-da21b56ab803"}}}]}, {"uuid": "c17dc359-c1e8-4ac0-b8b5-6f4911806a06", "name": "load_p1rlv17413_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f147f7e5-33e8-430b-9822-715e772debb3"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "a1f185f9-ed32-4e4d-8ab5-4cb30f46e1fa"}}}}, {"uuid": "2b1560aa-044b-4355-a313-8393ed56e206", "name": "7091f011-29cf-4970-a077-57d16406022c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.892763602300674, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6648734705927571, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4bc73f95-dad0-426c-9936-a29efa07e8e8", "name": "54d54f42-88ad-4e97-8ab7-0abf5a820925", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2b1560aa-044b-4355-a313-8393ed56e206"}}}]}, {"uuid": "bdf7f58c-d310-4d81-a73e-f4b0b1a4ce42", "name": "load_p1rlv18362_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a28b095-45f5-43ec-983b-c1de596d4cb5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4bc73f95-dad0-426c-9936-a29efa07e8e8"}}}}, {"uuid": "257a4574-d5ef-4c96-9b9f-d77e051fafe0", "name": "91b731da-63f3-4bc2-b6e9-af3b83093c8d_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 2.892763602300674, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.6648734705927571, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d8380065-441a-43ce-be4c-f8346bb2f521", "name": "2874337f-dfcb-4793-be27-1510b75a005f", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "257a4574-d5ef-4c96-9b9f-d77e051fafe0"}}}]}, {"uuid": "d490ecf2-bbea-47c7-acb6-20d2732d4e2e", "name": "load_p1rlv18362_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a28b095-45f5-43ec-983b-c1de596d4cb5"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d8380065-441a-43ce-be4c-f8346bb2f521"}}}}, {"uuid": "75ddb8f7-60f7-490b-bf33-5873e706c7bf", "name": "87c379cb-60d1-4d1c-a9cd-99664fa99d1c_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6733980323267108, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22626974414284334, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "584dc0fb-4cac-4f30-9134-437168f50f38", "name": "b498951a-0c47-4046-ad51-574662d33fe5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "75ddb8f7-60f7-490b-bf33-5873e706c7bf"}}}]}, {"uuid": "16da4765-2a94-42b2-8fa3-ee4d896e71d7", "name": "load_p1rlv18364_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d1c3d0a-9def-4516-8429-386f1d70f506"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "584dc0fb-4cac-4f30-9134-437168f50f38"}}}}, {"uuid": "92e69644-de04-43d7-b2e1-0e3bd74982eb", "name": "266a88e0-df41-41ca-bfb6-60e12a5941f7_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.6733980323267108, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.22626974414284334, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e9864b39-af63-4922-a8d4-02e847767bcc", "name": "a91ad431-0ff6-4239-b74c-a5d9e3850a5c", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "92e69644-de04-43d7-b2e1-0e3bd74982eb"}}}]}, {"uuid": "da244663-5b6a-4fd8-a1f5-ac4badf33a37", "name": "load_p1rlv18364_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d1c3d0a-9def-4516-8429-386f1d70f506"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e9864b39-af63-4922-a8d4-02e847767bcc"}}}}, {"uuid": "a9ddfd1d-3312-40ce-bb2e-0ad14e5534c0", "name": "1952fc3c-5bb1-4426-aedd-3b281fbbcce4_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5880239691905954, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.38099900657746644, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "4b8ad38a-67e8-44ef-85a8-e7448d462d0f", "name": "66287ea0-a48c-4197-8596-01b7383329a5", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "a9ddfd1d-3312-40ce-bb2e-0ad14e5534c0"}}}]}, {"uuid": "b9c897cb-86a2-49e9-9eb4-373574153ce3", "name": "load_p1rlv18367_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "408c825d-17ac-4aea-9fc7-fff420657fc7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "4b8ad38a-67e8-44ef-85a8-e7448d462d0f"}}}}, {"uuid": "743c8186-d479-45e9-b3bc-a35e639913a6", "name": "5dd5f3e7-b82b-4663-aa29-5f66bf7ec617_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.5880239691905954, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.38099900657746644, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "accd5657-d180-46cc-b3f6-078c5d6c4023", "name": "ef824912-fe95-47a6-a947-dc3cd4ae0fe6", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "743c8186-d479-45e9-b3bc-a35e639913a6"}}}]}, {"uuid": "2bb645d5-61aa-411d-a6ca-d3858ae387f3", "name": "load_p1rlv18367_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "408c825d-17ac-4aea-9fc7-fff420657fc7"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "accd5657-d180-46cc-b3f6-078c5d6c4023"}}}}, {"uuid": "7b1b9654-8f6f-41f8-9949-7c667f121221", "name": "ae93fb7d-8b86-4bc8-8c76-23340af3316e_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.287089484997603, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1789824543876289, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "40b0ac72-0e92-4d11-8da5-eac2a4d51459", "name": "a32daa16-e1f3-4307-b131-b623a894e02a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "7b1b9654-8f6f-41f8-9949-7c667f121221"}}}]}, {"uuid": "188c068c-f0d5-42db-b95f-b14c18ac3ead", "name": "load_p1rlv18370_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905e171c-13d7-4f8d-b88a-7501b2327d81"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "40b0ac72-0e92-4d11-8da5-eac2a4d51459"}}}}, {"uuid": "68317224-66ee-48bc-b78a-da4bb713889f", "name": "e2e5bbaa-022b-4234-992f-0c2ac3cf90a1_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 4.287089484997603, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.1789824543876289, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "41fea339-814b-42d1-8c26-64a3fa35ebbe", "name": "18efa5ce-5d1b-485f-9ecc-c872b07928f1", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "68317224-66ee-48bc-b78a-da4bb713889f"}}}]}, {"uuid": "9ae409db-c6ba-45ca-9a8a-331455db2e0e", "name": "load_p1rlv18370_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905e171c-13d7-4f8d-b88a-7501b2327d81"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "41fea339-814b-42d1-8c26-64a3fa35ebbe"}}}}, {"uuid": "793805f3-a494-4fa1-a522-74e0ac925749", "name": "dfb5f81d-e24b-45c7-8605-ddb09f7d9eb3_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2520868864654517, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.447133871274774, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "d5aa70af-2ee7-4b7d-b94f-3ea222b385c2", "name": "125e24fe-6596-4d6d-94db-5dbf4bc5e421", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "793805f3-a494-4fa1-a522-74e0ac925749"}}}]}, {"uuid": "0f43e824-7939-4679-98c8-608f518dd550", "name": "load_p1rlv18371_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58792e8c-3ad9-45bb-ac47-01983cca2a2b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "d5aa70af-2ee7-4b7d-b94f-3ea222b385c2"}}}}, {"uuid": "69f19827-944b-4a54-a28e-0dfe9c47b0fc", "name": "390f6dbf-4017-4c8e-bceb-b4bfeb8f2003_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.2520868864654517, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.447133871274774, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "e70868cc-51f0-42a5-819e-83d4b3dbf361", "name": "931fc67d-b740-4547-9b8b-b33ffdbde5cb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "69f19827-944b-4a54-a28e-0dfe9c47b0fc"}}}]}, {"uuid": "67f1c6b3-83b2-48f1-9099-9b28b64418ad", "name": "load_p1rlv18371_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58792e8c-3ad9-45bb-ac47-01983cca2a2b"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "e70868cc-51f0-42a5-819e-83d4b3dbf361"}}}}, {"uuid": "b686fa6e-2461-4808-9066-25867f45ba9d", "name": "420e1a0a-ffcb-4581-8b92-d552392c4fee_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8791002615066037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24190904367644575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "b9fcde9a-cbbd-4ec9-92f8-ff41efd0cf35", "name": "7c92f79e-4b96-4736-b8a9-6742d7ac1ddb", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "b686fa6e-2461-4808-9066-25867f45ba9d"}}}]}, {"uuid": "b7724836-8957-44b6-a1ee-1e13527201ca", "name": "load_p1rlv22745_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a86348e4-7573-4903-b223-90155579923e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "b9fcde9a-cbbd-4ec9-92f8-ff41efd0cf35"}}}}, {"uuid": "53db9d3b-3c21-40c5-80a9-ef617736c9a8", "name": "5ff251b3-da3d-4586-825b-ac39058ba513_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 0.8791002615066037, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.24190904367644575, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "5a8333e2-17ee-4e51-a880-051e78240562", "name": "4aaed0fb-53e6-4c5b-9cab-4e1899e05ed4", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "53db9d3b-3c21-40c5-80a9-ef617736c9a8"}}}]}, {"uuid": "85381bbb-b76b-4491-8426-3f1f546557da", "name": "load_p1rlv22745_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a86348e4-7573-4903-b223-90155579923e"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "5a8333e2-17ee-4e51-a880-051e78240562"}}}}, {"uuid": "2616a540-3729-4d1c-9e19-3e6dd7591c99", "name": "0d546f4b-fb69-4955-892c-71bff61644ad_1", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4163439957648214, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5697938312046736, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "573e0cb7-9d98-4b90-8399-be6d8152d6aa", "name": "8080e54c-51ef-46b6-b0ec-6207aec4ee3e", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "2616a540-3729-4d1c-9e19-3e6dd7591c99"}}}]}, {"uuid": "e52b1a47-a419-442d-ad0a-75dd5602f688", "name": "load_p1rlv22758_1", "substation": null, "feeder": null, "in_service": true, "phases": ["S1"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db05b7f0-d2a8-4876-876e-ef0e9b469580"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "573e0cb7-9d98-4b90-8399-be6d8152d6aa"}}}}, {"uuid": "6e457b9f-df86-4742-8b47-d0463266fc5c", "name": "f96e1a4f-9a54-4b4c-b072-9ccb0d534841_2", "z_real": 0.0, "z_imag": 0.0, "i_real": 0.0, "i_imag": 0.0, "p_real": 1.0, "p_imag": 1.0, "num_customers": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "base"}}, "real_power": {"value": 1.4163439957648214, "units": "kilowatt", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "ActivePower", "serialized_type": "quantity"}}}, "reactive_power": {"value": 0.5697938312046736, "units": "kilovar", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactivePower", "serialized_type": "quantity"}}}}, {"uuid": "6733e95a-a926-463a-b097-3eadebfffe1b", "name": "f77f6636-5ffb-4446-a8c7-6d920b16449a", "connection_type": "STAR", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "base"}}, "phase_loads": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.phase_load_equipment", "type": "PhaseLoadEquipment", "serialized_type": "composed_component", "uuid": "6e457b9f-df86-4742-8b47-d0463266fc5c"}}}]}, {"uuid": "462e1f9c-3a5f-4f5b-a281-0d93e7ab513d", "name": "load_p1rlv22758_2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2"], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_load", "type": "DistributionLoad", "serialized_type": "base"}}, "bus": {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db05b7f0-d2a8-4876-876e-ef0e9b469580"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.load_equipment", "type": "LoadEquipment", "serialized_type": "composed_component", "uuid": "6733e95a-a926-463a-b097-3eadebfffe1b"}}}}, {"uuid": "e4ea7fd7-7dd6-4aa3-b984-f4806c69c9cd", "name": "", "resistance": 0.33831264, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 3, "connection_type": "DELTA", "tap_positions": [1.0, 1.0, 1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 39.838337182448036, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 30000.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "9a9d218f-3818-4abe-9c9f-7fee34acb7cc", "name": "", "resistance": 0.33831264, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 3, "connection_type": "STAR", "tap_positions": [1.03125, 1.03125, 1.03125], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.199769053117783, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 30000.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "0ff22131-b16e-4e2e-808a-862b62584bf5", "name": "5ea8fd3b-2d5b-4c48-84db-0b2934c03576", "pct_no_load_loss": 0.0, "pct_full_load_loss": 0.67662528, "coupling_sequences": [[1, 2]], "winding_reactances": [7.40307669516232], "is_center_tapped": false, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "e4ea7fd7-7dd6-4aa3-b984-f4806c69c9cd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "9a9d218f-3818-4abe-9c9f-7fee34acb7cc"}}}]}, {"uuid": "43f6bef8-6670-432e-967e-238f41116cd3", "name": "", "resistance": 0.266272, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.2, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 25.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "d7f56744-2b80-450f-96df-d394c22746ae", "name": "", "resistance": 0.532544, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 0.12, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 25.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "fc204377-0430-4e39-92d8-12637b9626bd", "name": "c90ce3f4-34f4-43b1-9398-685a67188e1f", "pct_no_load_loss": 0.472, "pct_full_load_loss": 0.798816, "coupling_sequences": [[1, 2], [1, 3], [2, 3]], "winding_reactances": [2.4, 1.6, 2.4], "is_center_tapped": true, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "43f6bef8-6670-432e-967e-238f41116cd3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "d7f56744-2b80-450f-96df-d394c22746ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "d7f56744-2b80-450f-96df-d394c22746ae"}}}]}, {"uuid": "409027f9-8175-46a5-9446-3197e251f48e", "name": "", "resistance": 0.41605, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.2, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 10.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "9482a710-e97e-42d4-9afe-b8a7af1d4dd2", "name": "", "resistance": 0.832101, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 0.12, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 10.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39", "name": "4e1e5ead-0aba-4efa-8a66-7f0837cdfdb3", "pct_no_load_loss": 0.68, "pct_full_load_loss": 1.248151, "coupling_sequences": [[1, 2], [1, 3], [2, 3]], "winding_reactances": [1.08, 0.72, 1.08], "is_center_tapped": true, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "409027f9-8175-46a5-9446-3197e251f48e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "9482a710-e97e-42d4-9afe-b8a7af1d4dd2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "9482a710-e97e-42d4-9afe-b8a7af1d4dd2"}}}]}, {"uuid": "af41736a-6c75-4cfe-a051-04f517ad6634", "name": "", "resistance": 0.16642, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.2, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 75.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "a59da237-5e2b-4026-aa20-285c4f5ac91a", "name": "", "resistance": 0.33284, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 0.12, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 75.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "e2f53d7d-7442-4b42-8617-11656e408189", "name": "7069cfb8-3af7-4776-b0a7-3ee93d0a6d00", "pct_no_load_loss": 0.38, "pct_full_load_loss": 0.49926, "coupling_sequences": [[1, 2], [1, 3], [2, 3]], "winding_reactances": [2.4, 1.6, 2.4], "is_center_tapped": true, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "af41736a-6c75-4cfe-a051-04f517ad6634"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "a59da237-5e2b-4026-aa20-285c4f5ac91a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "a59da237-5e2b-4026-aa20-285c4f5ac91a"}}}]}, {"uuid": "e45fd6cc-f0ba-4fec-a6cc-8de2e6071dd5", "name": "", "resistance": 0.87204, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 3, "connection_type": "STAR", "tap_positions": [1.0, 1.0, 1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.199769053117783, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 75.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "cedafdc8-4789-49a5-b801-1112786f4229", "name": "", "resistance": 0.87204, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 3, "connection_type": "STAR", "tap_positions": [1.0, 1.0, 1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 0.27713625866050806, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 75.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39", "name": "25e347d1-54f4-4401-a111-bc5b034415d8", "pct_no_load_loss": 0.6, "pct_full_load_loss": 1.74408, "coupling_sequences": [[1, 2]], "winding_reactances": [3.24], "is_center_tapped": false, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "e45fd6cc-f0ba-4fec-a6cc-8de2e6071dd5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "cedafdc8-4789-49a5-b801-1112786f4229"}}}]}, {"uuid": "5f0d2c9e-13b8-4f29-8af9-6188720eedac", "name": "", "resistance": 0.199704, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.2, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 50.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "43ae60da-acbb-41be-b1e9-850c4e760ec4", "name": "", "resistance": 0.399408, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 0.12, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 50.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208", "name": "dcf66ff7-2c37-4071-944c-a1a7c55efdd0", "pct_no_load_loss": 0.37, "pct_full_load_loss": 0.599112, "coupling_sequences": [[1, 2], [1, 3], [2, 3]], "winding_reactances": [2.4, 1.6, 2.4], "is_center_tapped": true, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "5f0d2c9e-13b8-4f29-8af9-6188720eedac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "43ae60da-acbb-41be-b1e9-850c4e760ec4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "43ae60da-acbb-41be-b1e9-850c4e760ec4"}}}]}, {"uuid": "a0c12460-ccac-452f-9740-c1574cf5bb1f", "name": "", "resistance": 0.266272, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.2, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 50.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "f6e9a1ac-c88b-4fe2-a154-24f5f7642ecf", "name": "", "resistance": 0.532544, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 0.12, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 50.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "fac52057-f5c2-4934-9fe6-6517159b5db2", "name": "c008ed76-f669-42ff-b5cd-d16b05f9d6a9", "pct_no_load_loss": 0.472, "pct_full_load_loss": 0.798816, "coupling_sequences": [[1, 2], [1, 3], [2, 3]], "winding_reactances": [2.4, 1.6, 2.4], "is_center_tapped": true, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "a0c12460-ccac-452f-9740-c1574cf5bb1f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "f6e9a1ac-c88b-4fe2-a154-24f5f7642ecf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "f6e9a1ac-c88b-4fe2-a154-24f5f7642ecf"}}}]}, {"uuid": "777a7223-aa6f-4f59-8319-64339d066aab", "name": "93ddfc44-8481-4bdf-ab60-e9ff52bb462f", "pct_no_load_loss": 0.37, "pct_full_load_loss": 0.798816, "coupling_sequences": [[1, 2], [1, 3], [2, 3]], "winding_reactances": [2.4, 1.6, 2.4], "is_center_tapped": true, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "a0c12460-ccac-452f-9740-c1574cf5bb1f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "f6e9a1ac-c88b-4fe2-a154-24f5f7642ecf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "f6e9a1ac-c88b-4fe2-a154-24f5f7642ecf"}}}]}, {"uuid": "bd55901d-7c9b-4820-ae8e-57c9ca06328f", "name": "", "resistance": 0.266272, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.2, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 75.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "cd8890eb-9546-4f24-acce-6fcf2ee84c86", "name": "", "resistance": 0.532544, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 0.12, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 75.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "5b183af9-59bd-450e-bea6-e545db99accd", "name": "9d1848f6-5882-41b9-b2a8-c82d69262c5d", "pct_no_load_loss": 0.37, "pct_full_load_loss": 0.798816, "coupling_sequences": [[1, 2], [1, 3], [2, 3]], "winding_reactances": [2.4, 1.6, 2.4], "is_center_tapped": true, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "bd55901d-7c9b-4820-ae8e-57c9ca06328f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "cd8890eb-9546-4f24-acce-6fcf2ee84c86"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "cd8890eb-9546-4f24-acce-6fcf2ee84c86"}}}]}, {"uuid": "d7f8bb16-2fa2-44b9-9ef9-402d0cdb4de0", "name": "", "resistance": 0.41605, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 7.2, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 25.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "13913f15-8cf3-4455-991c-233f79168c29", "name": "", "resistance": 0.832101, "is_grounded": false, "voltage_type": "line-to-ground", "num_phases": 1, "connection_type": "STAR", "tap_positions": [1.0], "total_taps": 32, "min_tap_pu": 0.9, "max_tap_pu": 1.1, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "base"}}, "nominal_voltage": {"value": 0.12, "units": "kilovolt", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Voltage", "serialized_type": "quantity"}}}, "rated_power": {"value": 25.0, "units": "kilova", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ApparentPower", "serialized_type": "quantity"}}}}, {"uuid": "7ecefea9-516a-4cb1-8c06-cac3a09bcc5e", "name": "c3e09961-f803-4e36-b0bb-ca80f2402057", "pct_no_load_loss": 0.68, "pct_full_load_loss": 1.248151, "coupling_sequences": [[1, 2], [1, 3], [2, 3]], "winding_reactances": [1.08, 0.72, 1.08], "is_center_tapped": true, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "base"}}, "windings": [{"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "d7f8bb16-2fa2-44b9-9ef9-402d0cdb4de0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "13913f15-8cf3-4455-991c-233f79168c29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "WindingEquipment", "serialized_type": "composed_component", "uuid": "13913f15-8cf3-4455-991c-233f79168c29"}}}]}, {"uuid": "cb14ae0e-2eb0-4352-9990-bab8587ecbc3", "name": "sb10_p1rhs7_1247_trans_301", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16bb904e-b153-4b0a-97f5-53ad7c6606d8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "001adbd4-6616-4dce-83d2-025e896ada51"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0ff22131-b16e-4e2e-808a-862b62584bf5"}}}}, {"uuid": "0f8211a9-3a1c-4289-91ed-70595408cdb6", "name": "tr(r:p1rdt4964-p1rdt4964lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7f13598-e628-457c-9ba6-d9a0123e882c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3541a1a-9680-4baf-9b87-a1322cb1a16a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3541a1a-9680-4baf-9b87-a1322cb1a16a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "4459a649-5f2a-49a5-ad44-234e0a27c101", "name": "tr(r:p1rdt4980-p1rdt4980lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ddb0629-4947-47ca-83f9-9b7c073db235"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab731358-e17f-4c48-b6f8-c7bb4c7701de"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab731358-e17f-4c48-b6f8-c7bb4c7701de"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "a14eb44e-8274-4874-9188-51fccadf71e2", "name": "tr(r:p1rdt5017-p1rdt5017lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c09f718-9379-4281-86f6-55c46e46aec6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0375d197-ccd2-4ed8-9439-857b700cefb8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0375d197-ccd2-4ed8-9439-857b700cefb8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f59e21f9-fe45-41c0-9dfb-d93eeb5c5a9b", "name": "tr(r:p1rdt5126-p1rdt5126lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0dafde2-c08e-4624-9212-e0fea9e47c2c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e33e473-8d5b-4704-bdab-56032991f94e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e33e473-8d5b-4704-bdab-56032991f94e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "a224a322-e724-45d6-b4de-232506f9f06e", "name": "tr(r:p1rdt5140-p1rdt5140lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b0fd055-d0ac-4678-a8e5-679e12741736"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f114a56-98d7-4fe8-b0b1-b8c4bc791cf9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f114a56-98d7-4fe8-b0b1-b8c4bc791cf9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "8d206fac-69f4-4fad-9199-94c1209314a0", "name": "tr(r:p1rdt5142-p1rdt5142lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d579047b-82f6-49bf-bd7b-28c818d44bb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e071635-4071-470d-be09-4484cb90441a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e071635-4071-470d-be09-4484cb90441a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "316c1908-f8c8-4724-99c8-68acd6ca28e6", "name": "tr(r:p1rdt5153-p1rdt5153lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb8dae66-287a-4b8a-9cda-6ae02cb8f8a9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ec20ad2-b04f-43fc-ad8d-d41746549a57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ec20ad2-b04f-43fc-ad8d-d41746549a57"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "f6e301fe-1473-4823-8abc-5bb307b2ce1a", "name": "tr(r:p1rdt5154-p1rdt5154lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50332aed-ecfd-465a-977e-c24ed6462860"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9750085f-4afd-48ee-89f3-edbe9687b242"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "5e034209-8f4d-4112-bf2e-fc5d831d0b41", "name": "tr(r:p1rdt5155-p1rdt5155lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16712e10-4c7f-428b-917b-135ab3c2d4b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85351f49-cb19-4f71-a6ae-a21f5a48af6f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85351f49-cb19-4f71-a6ae-a21f5a48af6f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "5a444dd7-7ccc-4ad8-bdb1-e278ecb6ab5b", "name": "tr(r:p1rdt5159-p1rdt5159lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90fb2270-4759-4779-80c1-7f93d66e1c53"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba7e3a6b-f62f-432f-afe7-2ebbfc9abd59"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba7e3a6b-f62f-432f-afe7-2ebbfc9abd59"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "224f6b7f-ed33-4683-96f3-f5463456d1f4", "name": "tr(r:p1rdt5172-p1rdt5172lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ea481f8-b9c7-4067-9bfb-4f7cdc5dee15"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48efdcb9-083c-4e17-a1d2-acb1388f085e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48efdcb9-083c-4e17-a1d2-acb1388f085e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d096b871-d8cf-49e3-a9d8-bce4ee870d37", "name": "tr(r:p1rdt5179-p1rdt5179lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d22f1247-b756-4498-8cf8-fef7d1e859ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd4155b2-ca55-41d7-bd35-98a5eec8c39a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd4155b2-ca55-41d7-bd35-98a5eec8c39a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "03f5affd-877c-44f3-a574-df7d0a34d7bf", "name": "tr(r:p1rdt5180-p1rdt5180lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6316fa2-dd57-46d4-89c0-f11dd675d686"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae26acb3-c2c9-479c-9d19-c30bf00aa8c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae26acb3-c2c9-479c-9d19-c30bf00aa8c5"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "1b56638f-139e-4db8-93ee-87c32a4330ef", "name": "tr(r:p1rdt5183-p1rdt5183lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23f0bb81-3c30-45a5-89ca-2011e3881ddb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bbde2e8-42c0-486b-9759-78898d177f93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bbde2e8-42c0-486b-9759-78898d177f93"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4d397307-5f03-484b-bb97-2343016c603d", "name": "tr(r:p1rdt5184-p1rdt5184lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "431b672b-cb45-4294-b1f9-1d63f4efc8db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1656cc28-8a5b-40da-887f-25605dd336aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1656cc28-8a5b-40da-887f-25605dd336aa"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "7cee3b1b-3e70-4066-ae18-13419331a26b", "name": "tr(r:p1rdt5195-p1rdt5195lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58c6d858-d457-4fe6-a45b-b9b2b73cad8c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf05c1bb-39cc-48b3-a576-18913e0cff13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf05c1bb-39cc-48b3-a576-18913e0cff13"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "39039b81-4e2f-42c7-b890-1bf3d089058a", "name": "tr(r:p1rdt5200-p1rdt5200lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "799ab435-c0a4-4515-8125-e8ca2fb7632d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "03e7bfdb-ff8b-4142-95ef-8d848ff5d2db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "03e7bfdb-ff8b-4142-95ef-8d848ff5d2db"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "02b53edb-2e1f-4263-9d58-d6f7837fee8b", "name": "tr(r:p1rdt5201-p1rdt5201lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c289632-ba52-4b65-b6da-ac76b1477246"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8162a8c-5339-4f42-bd7a-b6dbc5ff463b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8162a8c-5339-4f42-bd7a-b6dbc5ff463b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "403188b7-0c92-46b1-b0a0-72798d290fa2", "name": "tr(r:p1rdt5202-p1rdt5202lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97e4f179-9d60-4183-8326-eb0ab98a53eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "39eaedd7-75b6-449f-8ff6-6e31f6e74504"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "39eaedd7-75b6-449f-8ff6-6e31f6e74504"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b875dd86-44ae-41fc-b621-1d50fd1369ab", "name": "tr(r:p1rdt5206-p1rdt5206lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ed081eb-6b56-43b8-9cf8-e7ffdd8222f2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "599a2995-33d5-4bcc-8cd3-585ea37577cd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "599a2995-33d5-4bcc-8cd3-585ea37577cd"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "cfd7929a-5a92-40d0-8117-68f69e67d917", "name": "tr(r:p1rdt5218-p1rdt5218lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dda7f7c-3b21-46a0-88a3-2b7f028b7772"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c650eda9-132b-4419-a055-ad68037c7772"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c650eda9-132b-4419-a055-ad68037c7772"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "e226528d-6510-43cc-9946-faedc99958f7", "name": "tr(r:p1rdt5236-p1rdt5236lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22db53ea-6d9a-4527-9b36-34a4bcd2c74f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f252d81-66ee-40a6-bce7-2891e06b39e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f252d81-66ee-40a6-bce7-2891e06b39e4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "897a5ce1-914d-454b-a71c-5980ff30cc2f", "name": "tr(r:p1rdt5342-p1rdt5342lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c8f9ea6-06fb-4fd0-8629-ceea4f32189f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e01069aa-388b-4362-9d02-a164f173dc20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e01069aa-388b-4362-9d02-a164f173dc20"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "519868f4-b58e-4fdc-b749-5324585674fa", "name": "tr(r:p1rdt5472-p1rdt5472lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a8c3f7f-b9be-4c5e-b6f0-8f2fc18935fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34a1276e-c702-4c69-b7b1-566d400da2de"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34a1276e-c702-4c69-b7b1-566d400da2de"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "3afcd18e-c615-4125-9695-1bf38cf70f51", "name": "tr(r:p1rdt5475-p1rdt5475lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b9e57e0-6dc8-4831-ac7d-36f8608b7a8d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d181674-9355-488b-8a3f-5b7c844c35a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d181674-9355-488b-8a3f-5b7c844c35a5"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "5cd3e55d-3396-480b-b9cd-00b92b563c79", "name": "tr(r:p1rdt5476-p1rdt5476lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b077dc9c-1c6f-4403-ae0c-954e7cc0c692"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0888f4c5-e037-4891-99fb-fd43934ffae0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0888f4c5-e037-4891-99fb-fd43934ffae0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "38e532e3-559a-4907-853d-7cd08b7d5493", "name": "tr(r:p1rdt5477-p1rdt5477lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7d7f462-1ab5-4fd8-baaa-7e576eead5c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fafd64c3-efe5-4684-b06f-44e4c8555aa4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fafd64c3-efe5-4684-b06f-44e4c8555aa4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "473cf7e7-cc10-4402-a7d2-42b4288be59b", "name": "tr(r:p1rdt5478-p1rdt5478lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a97491e-2c98-4584-9b74-5593f17faeda"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5107bc9c-f463-49f6-a92f-23c5730475e2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5107bc9c-f463-49f6-a92f-23c5730475e2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "f3d168ab-98b0-4f71-a258-4db4b923422f", "name": "tr(r:p1rdt5480-p1rdt5480lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2568f11c-8a37-4a55-8bce-9f0d56ac386a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44ac9e38-8ae3-4102-822b-1c638a6c878a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44ac9e38-8ae3-4102-822b-1c638a6c878a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6ab40212-5945-4e0d-be6c-547813180165", "name": "tr(r:p1rdt5481-p1rdt5481lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d29d8b74-a24d-4474-9752-c1ffa1aa7f7c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f213ee9e-6ae7-4e82-9f25-6fc456f45576"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f213ee9e-6ae7-4e82-9f25-6fc456f45576"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "804a9ecc-be85-4926-84d2-1879c6008a6e", "name": "tr(r:p1rdt5483-p1rdt5483lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f903015c-95a7-4d6e-b2a5-e9705c050c6e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a73d544-9f33-49d9-b648-c806addf3c06"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a73d544-9f33-49d9-b648-c806addf3c06"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "e47a7160-32cb-47d7-a35d-f30bb1d87bc9", "name": "tr(r:p1rdt5485-p1rdt5485lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cfb3a23-3a93-4d89-8b70-e4730ebbce1a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40eaefce-482f-4a89-bec1-2c11bac2bfb7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40eaefce-482f-4a89-bec1-2c11bac2bfb7"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "3c03d8f3-d40a-4b30-8f4b-39116f72993e", "name": "tr(r:p1rdt5650-p1rdt5650lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8f1c67e-9e29-45a3-a2a3-c2f3493a6898"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28a6e44b-c6c7-4556-b4d8-d55359391c66"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28a6e44b-c6c7-4556-b4d8-d55359391c66"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "442a6df8-1877-4263-a9de-b6a18ae053ad", "name": "tr(r:p1rdt5653-p1rdt5653lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "769c14db-ac3f-438d-9f7d-c7eb2d3074b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38d1de19-1f51-4875-acc2-a75e3d1a290e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38d1de19-1f51-4875-acc2-a75e3d1a290e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b88a89f2-d5e8-45bd-939b-2476952d2902", "name": "tr(r:p1rdt5656-p1rdt5656lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f417a58d-5a47-4310-bac6-e8bb95fffc19"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "87e8c57e-67ff-439c-b28b-0fbdbfd62ea6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "87e8c57e-67ff-439c-b28b-0fbdbfd62ea6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "a62dc441-3832-46a8-9fe3-5ad01441938c", "name": "tr(r:p1rdt5658-p1rdt5658lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81d6db26-881f-4cae-9514-df4c1e71c76e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f718935b-704d-4374-9172-856511e1eddd"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "1bc7dee2-3a73-4bf6-b9e5-5a51eb44b4ff", "name": "tr(r:p1rdt5662-p1rdt5662lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17e89212-bc51-4fc2-83d1-4c74a285be23"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea73a91a-b052-486e-810b-1a5ad281e07b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea73a91a-b052-486e-810b-1a5ad281e07b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "48c1ed45-922f-4c58-b9d0-26d6c91138f3", "name": "tr(r:p1rdt5663-p1rdt5663lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7356d982-36fd-46cb-9300-8889502e8dc8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16a67a88-5d11-4eca-85fe-38c948ad362c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16a67a88-5d11-4eca-85fe-38c948ad362c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "85ffc857-6af0-4a86-bcdd-734da36e5718", "name": "tr(r:p1rdt5728-p1rdt5728lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b55c58cf-153e-4aa3-b099-8a1db05a6ae5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6d456893-4d89-455a-b1a5-4863aad6293a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6d456893-4d89-455a-b1a5-4863aad6293a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4f92fde2-27d2-48b7-aab1-425ccf2fedee", "name": "tr(r:p1rdt5729-p1rdt5729lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "77d2122b-cbb7-4844-bbb2-55e939431e50"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95f81d7a-a6af-4843-bfa1-002abc7ff870"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95f81d7a-a6af-4843-bfa1-002abc7ff870"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "0783f792-d931-4d06-a008-d6dff90de5cb", "name": "tr(r:p1rdt5730-p1rdt5730lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5897bb2-1f72-4aeb-9090-74e2411b5786"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2dd206bc-965d-46c9-8fdb-8c158c7bba05"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2dd206bc-965d-46c9-8fdb-8c158c7bba05"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "5a2f8d06-f5c2-4ff9-befb-b1580884d748", "name": "tr(r:p1rdt5731-p1rdt5731lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95cd61cf-f1cb-4af2-9d3b-e42978642003"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e414162-eda7-4cf2-9116-fc24af9461bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e414162-eda7-4cf2-9116-fc24af9461bf"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6d3ddf78-01dd-4545-865b-513b8a016d38", "name": "tr(r:p1rdt5840-p1rdt5840lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35722d90-049e-4c67-9654-acce0572e6c2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9974869d-7d87-4a27-9606-076cd7799953"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9974869d-7d87-4a27-9606-076cd7799953"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "7a69c32d-25c9-4ba6-9763-bc883b42aec6", "name": "tr(r:p1rdt5923-p1rdt5923lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fec8a81-a151-4d8f-adc7-6d6d87d7759f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "751d2f2e-bb6f-4ca6-9e86-0e2b5ff3f92a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "751d2f2e-bb6f-4ca6-9e86-0e2b5ff3f92a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "7c2647c5-6bca-4086-b50e-8dc4d3699dd7", "name": "tr(r:p1rdt6038-p1rdt6038lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8898950-d712-40dc-99b5-33882b96b225"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d654945d-b71d-4943-86a2-5830fca200c9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d654945d-b71d-4943-86a2-5830fca200c9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4f7e809a-a82d-4bf0-ac51-229280ce4fd9", "name": "tr(r:p1rdt6043-p1rdt6043lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "87e05b2f-c346-452c-9c72-a6db090c3124"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ae7bbf-f53e-4ae2-8145-bf56ce935094"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ae7bbf-f53e-4ae2-8145-bf56ce935094"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fac52057-f5c2-4934-9fe6-6517159b5db2"}}}}, {"uuid": "df4304d6-f35e-4caa-b702-71b3da08c77f", "name": "tr(r:p1rdt6045-p1rdt6045lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0396342e-2dc8-4a01-9da9-513953f9b5fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70bad714-71c1-4341-ac40-76312417dd03"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "1fda4c61-98bf-494b-a4be-a77eef41867b", "name": "tr(r:p1rdt6046-p1rdt6046lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67bc3ce6-e23d-4899-b0e8-9783225338ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2e2d1a7-039c-4b29-a061-b814ac675e3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2e2d1a7-039c-4b29-a061-b814ac675e3b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "123088f7-943a-4feb-845b-85900240a87f", "name": "tr(r:p1rdt6047-p1rdt6047lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34a9d21e-bcf7-4266-9834-60a72878ddd4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21e75ccd-7e21-4f0d-890c-81aa6b33b109"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21e75ccd-7e21-4f0d-890c-81aa6b33b109"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "62ef838d-937e-4760-aabd-f8478054f480", "name": "tr(r:p1rdt6052-p1rdt6052lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c10f182d-aa76-4633-9a84-f41e20b97da1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d830a1b-6971-4f4d-99bd-945e0785b5aa"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "e1db1007-4c7e-413b-9d88-ee84e9bd8284", "name": "tr(r:p1rdt6208-p1rdt6208lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdfc617f-fbfb-4e9a-862e-cd5a296748cb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01be483b-09f4-450e-a39d-78692c40ee8b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01be483b-09f4-450e-a39d-78692c40ee8b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b0843684-b05b-4654-bc0e-d00707551a2b", "name": "tr(r:p1rdt6221-p1rdt6221lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0809ec5e-d36f-4bea-91b3-962ad6c29606"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73f78740-2ec5-4ad8-b7fb-40f4a72b730e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73f78740-2ec5-4ad8-b7fb-40f4a72b730e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "cf49bac9-27de-4e9d-98a7-f4a7be482fcf", "name": "tr(r:p1rdt6226-p1rdt6226lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d81fc6d7-3400-41d4-91d7-b350d7def98d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3154eee7-a1ba-4b9d-9e91-bab55529d358"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3154eee7-a1ba-4b9d-9e91-bab55529d358"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f910561f-ff5c-4353-ad1e-f22354339f22", "name": "tr(r:p1rdt6268-p1rdt6268lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2f8b91d-339f-4151-90df-b0cad5c2f05a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72ce0706-6b32-4b4b-9bf3-fd1f5a6af5ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72ce0706-6b32-4b4b-9bf3-fd1f5a6af5ca"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "d630f404-730d-43bf-adf8-c8d3a01cf56a", "name": "tr(r:p1rdt6269-p1rdt6269lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5ef97a6-6c60-46eb-acce-6469b273658a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79c91fa8-15ad-4e8d-96bd-2cad395dd280"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79c91fa8-15ad-4e8d-96bd-2cad395dd280"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "194e335f-7fd7-49b3-8533-23c4e6813e0e", "name": "tr(r:p1rdt6270-p1rdt6270lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cf36152-b3af-49f7-b693-5d465db1f283"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5adb2083-3d46-48a7-8996-37c0781b0215"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5adb2083-3d46-48a7-8996-37c0781b0215"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "cbbbeabe-626d-49b9-8577-1ddaec69fd68", "name": "tr(r:p1rdt6271-p1rdt6271lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a75c5e2-2277-42b4-87d4-6eadff5c06f1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1335e64c-9f37-4e73-a37f-8f76737cabff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1335e64c-9f37-4e73-a37f-8f76737cabff"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "74954554-5d2e-4b28-bb8d-40c669296046", "name": "tr(r:p1rdt6272-p1rdt6272lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "034bda10-d48e-449c-9255-247cbf718683"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04422e0a-1952-422d-a201-5fafef1875db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04422e0a-1952-422d-a201-5fafef1875db"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "cd6959a3-3d4c-4eae-aeee-0c9406c769c6", "name": "tr(r:p1rdt6273-p1rdt6273lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d04f281-f394-432b-8b5c-cc1acb741369"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07992f45-0c92-4a10-837d-4f58599d9b75"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "55aac547-fb88-4aa6-8809-ecd9a876ffa4", "name": "tr(r:p1rdt6274-p1rdt6274lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a53624b-8538-4cce-b588-c774875af31b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1db8c80-e791-4c31-a6f2-713aa665bf41"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1db8c80-e791-4c31-a6f2-713aa665bf41"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "0ba41d6b-5061-4da6-a3ac-bb25ac6bf459", "name": "tr(r:p1rdt6275-p1rdt6275lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08d4c459-5bc5-4cad-8e74-613c4a08cb35"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba567584-fbee-44eb-b3f1-da24a0ce66a0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba567584-fbee-44eb-b3f1-da24a0ce66a0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "0dd85bf1-32ee-4efa-9b79-2c455df5d785", "name": "tr(r:p1rdt6276-p1rdt6276lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "315af04d-a032-43a8-a2da-b9e68fd21f39"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f20ace2-5ec8-4451-b7e7-66f46c2c487b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f20ace2-5ec8-4451-b7e7-66f46c2c487b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ecf6f04d-159d-4f51-bf3e-799ca3b33afb", "name": "tr(r:p1rdt6277-p1rdt6277lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1dd4f893-7921-41c3-9e9e-d33e3680a999"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e582b04d-a8d8-4ee9-8576-1e5941623c0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e582b04d-a8d8-4ee9-8576-1e5941623c0b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "8e37ba75-2f21-4e53-a316-b5fab0dd5024", "name": "tr(r:p1rdt6278-p1rdt6278lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51eefb94-724e-4dfe-9823-0f6cf8f56101"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b37eabc-787a-491f-bc4f-956f43a862ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b37eabc-787a-491f-bc4f-956f43a862ff"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4a4f2957-d5d5-4b14-b64a-3c47edce713f", "name": "tr(r:p1rdt6279-p1rdt6279lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "632d8db5-5220-4188-94f0-f6131253820b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6614f5e-517f-46cf-b049-09337d57228a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "6f6b8188-d30e-42a1-93eb-2a1b1bc0bdad", "name": "tr(r:p1rdt6345-p1rdt6345lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40280da5-767c-4610-b6a8-ff411e1c33e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a38eb6d-a625-42a1-95f6-bbf078d1447a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a38eb6d-a625-42a1-95f6-bbf078d1447a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "70aa8f42-99ed-452a-b36c-f06fa56744da", "name": "tr(r:p1rdt6347-p1rdt6347lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7166849-6ecd-4270-bf52-d0579838336a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e40008af-ff50-42bd-8897-f663c27a436f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e40008af-ff50-42bd-8897-f663c27a436f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a13e6c46-4605-4824-91c2-352fb915a87b", "name": "tr(r:p1rdt6348-p1rdt6348lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d6c5b78-35c4-475a-8837-776dea236c95"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d84ac329-f314-41be-a2ee-89bc74789a18"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d84ac329-f314-41be-a2ee-89bc74789a18"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "4ff0e214-7067-4064-9386-9806caf80eaf", "name": "tr(r:p1rdt6349-p1rdt6349lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c1edcfa-e0e4-4493-a9bb-e6033185ce67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdfa0310-7dc5-4181-a64e-cc2522370547"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdfa0310-7dc5-4181-a64e-cc2522370547"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "11b74794-1c6f-47e4-a54f-433e3831c90c", "name": "tr(r:p1rdt6350-p1rdt6350lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c935f1c0-e36c-407d-a2e8-4181c4b0733e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0138b892-d18e-497c-9857-c4d5676deac2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0138b892-d18e-497c-9857-c4d5676deac2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4cd1169b-f163-4253-b934-0f8715170853", "name": "tr(r:p1rdt6353-p1rdt6353lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e51e0d9-24b6-40ac-859a-51ea74c93e76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "015322ae-7712-488f-9569-33fc785e4f62"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "015322ae-7712-488f-9569-33fc785e4f62"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c6442bf3-7517-47a1-a505-20f615795f42", "name": "tr(r:p1rdt6354-p1rdt6354lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a05e7c9-4bff-46fd-b356-8120b481b053"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f06a08bd-05ea-4914-b0d0-07cd0e83bfbc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f06a08bd-05ea-4914-b0d0-07cd0e83bfbc"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a2e09203-34e7-4304-9ef8-79ced26ee5cf", "name": "tr(r:p1rdt6355-p1rdt6355lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "88cc1382-6b14-4500-8a21-662fce6a0c0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1d14a79-4d18-43fe-8790-57ea9adf83a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1d14a79-4d18-43fe-8790-57ea9adf83a8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "7a9d98cb-9394-474e-837a-3acb6f94652b", "name": "tr(r:p1rdt6356-p1rdt6356lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1bdfc1ac-98a4-43dd-bb2c-837d0a2c15f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "548724aa-110a-428f-b71a-acdf0051dc39"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "548724aa-110a-428f-b71a-acdf0051dc39"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "058d6f19-56cc-412c-b1e5-cbcabe0dc8ca", "name": "tr(r:p1rdt6409-p1rdt6409lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42929633-40d4-4e13-a0aa-a7682f328226"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e36cfaaa-3996-4cc6-aa4f-170f20c5d1e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e36cfaaa-3996-4cc6-aa4f-170f20c5d1e0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a340529f-91b6-49c6-9dca-e2917c92ce4f", "name": "tr(r:p1rdt6498-p1rdt6498lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5c5466f-b7e4-4844-967b-9e8b11c68b44"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "e9dd0225-3992-43ea-8011-c92f7dd12ae0", "name": "tr(r:p1rdt6499-p1rdt6499lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "89434ebc-1e79-4414-9925-1a14f8e72fd6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb05d831-1556-4f56-8065-d9d16657caa3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb05d831-1556-4f56-8065-d9d16657caa3"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "78d55ca8-45d5-442d-8aff-41943123d90d", "name": "tr(r:p1rdt6500-p1rdt6500lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78b3b940-c277-441f-b2b3-83525ed85fcb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a20a4242-8a76-49f3-9bf5-3d7aaf751cdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a20a4242-8a76-49f3-9bf5-3d7aaf751cdc"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "4f669b5d-d8e9-463a-b26f-2a4ee9987301", "name": "tr(r:p1rdt6501-p1rdt6501lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99fa55d1-867c-4db0-8697-b532da10d6d4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "5b183af9-59bd-450e-bea6-e545db99accd"}}}}, {"uuid": "34a8f0cc-8b8d-4cbe-a72c-4953ada66769", "name": "tr(r:p1rdt6502-p1rdt6502lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e6348d4-7fcb-4546-af84-8ece75b6332f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7682e9f7-1272-4781-b128-34c7329afe49"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7682e9f7-1272-4781-b128-34c7329afe49"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d400dd14-c9f5-47a1-b904-0451078eb91b", "name": "tr(r:p1rdt6505-p1rdt6505lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb1c1e50-902d-443d-8c9a-b728d2f6b6f1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387e7785-8d40-4ddd-8c2b-14a83d4e7401"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387e7785-8d40-4ddd-8c2b-14a83d4e7401"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "aa0dde85-1b90-4171-9964-b45e0fba3d62", "name": "tr(r:p1rdt6507-p1rdt6507lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0db3e719-4dba-4b45-af70-c35546c19eb4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5844baa-5e0f-4edd-9122-fe4255adad0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5844baa-5e0f-4edd-9122-fe4255adad0b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "30e44c45-a02c-4cea-8908-3cc302637263", "name": "tr(r:p1rdt6508-p1rdt6508lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e165d0d-3f13-4d87-9c4b-fdfa8829f1f3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "e492a34f-e6bb-4fe5-81a5-90fd87eabde0", "name": "tr(r:p1rdt6509-p1rdt6509lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67c889f-e940-4242-9c83-4b5ab673d8a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f817a28f-c650-4eb4-84c0-751fe5053c75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f817a28f-c650-4eb4-84c0-751fe5053c75"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "c9ced24a-5b5b-4df7-8d09-09dd0242098b", "name": "tr(r:p1rdt6510-p1rdt6510lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "848c04de-e4d5-4520-9dce-0073776c2ae4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d62fe3b-7644-46d1-8a15-e86d95ae8b2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d62fe3b-7644-46d1-8a15-e86d95ae8b2a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "5b183af9-59bd-450e-bea6-e545db99accd"}}}}, {"uuid": "c4d3abcf-3d44-4600-8d3d-8ecbac558601", "name": "tr(r:p1rdt6512-p1rdt6512lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f7572ed-6443-4e6e-8fb8-0b060b9f17ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "c95fd30e-d8ee-4e73-8137-8809191cc304", "name": "tr(r:p1rdt6514-p1rdt6514lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0737f6ec-0d5d-4cff-b4b7-9910c7076984"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad6bef77-8f39-43b4-b2d7-58aa6e45a60b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad6bef77-8f39-43b4-b2d7-58aa6e45a60b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "f8a778f3-59c0-4bec-8421-fe311691a98e", "name": "tr(r:p1rdt6515-p1rdt6515lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1537ab1-dc7c-4bbd-b347-fc740d54fcf7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b92f8bcd-91ce-42bd-be69-0b43cb9d4122"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b92f8bcd-91ce-42bd-be69-0b43cb9d4122"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "04865f1a-c24c-4c01-9c2c-2f0900f03c59", "name": "tr(r:p1rdt6516-p1rdt6516lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5bd908fd-8bb8-42c1-8d1b-27c4e2574450"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "119a8559-8e6c-4314-9bbd-37ef3adde415"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "119a8559-8e6c-4314-9bbd-37ef3adde415"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "28fdc699-4ca3-4224-ab12-104819ba90f7", "name": "tr(r:p1rdt6517-p1rdt6517lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b56340a0-81f0-4028-9283-532f0d92a412"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5783bae9-2c74-473f-bf18-db40bc975409"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5783bae9-2c74-473f-bf18-db40bc975409"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f389fc04-f3b3-4f77-9b76-fd9e9c700eab", "name": "tr(r:p1rdt6518-p1rdt6518lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d39c608-5688-4e22-8ac4-96b896265274"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b16b03-1922-4aeb-8e70-d0e1387fbcab"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b16b03-1922-4aeb-8e70-d0e1387fbcab"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "ef0eea90-233c-45ea-8067-2c1f4945c601", "name": "tr(r:p1rdt6519-p1rdt6519lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "addd9f38-279f-4d9e-b216-38faef1940c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "606673ea-bcd2-459a-a0af-efb8b31c600c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "606673ea-bcd2-459a-a0af-efb8b31c600c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "59e61f1f-ded0-4c99-a73c-1f0eece1beda", "name": "tr(r:p1rdt6520-p1rdt6520lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24028ccd-3fd3-4461-b83c-54266f91a385"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13c02cd3-cff3-4988-95b9-3993b9541427"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13c02cd3-cff3-4988-95b9-3993b9541427"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "d566312d-edfe-48bf-928b-511d9fa3d857", "name": "tr(r:p1rdt6521-p1rdt6521lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "302d2adf-2199-47b2-9f3c-e428bb409b6f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0e4e42c-8dcd-47be-bfe8-b8b1eb4a5f24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0e4e42c-8dcd-47be-bfe8-b8b1eb4a5f24"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "01a96d6a-0929-49a6-b5bb-16ac567b9a88", "name": "tr(r:p1rdt6523-p1rdt6523lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b540c710-395d-4a35-8dc3-59d37609df09"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66df2481-ae4f-4f39-aef4-7af09ce1a8fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66df2481-ae4f-4f39-aef4-7af09ce1a8fb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "4121aff5-c528-4441-9261-8852d46e58af", "name": "tr(r:p1rdt6524-p1rdt6524lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ef8c502-c06f-43e5-90e6-23bd0ebcf155"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ec2137a-f978-4808-a023-21f13464998b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ec2137a-f978-4808-a023-21f13464998b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "0913bb9f-6019-467a-9487-635b1c029c69", "name": "tr(r:p1rdt6527-p1rdt6527lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "483b2d65-b496-4c6f-b01d-66aa3d9d4334"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8905812-7e3b-4875-87b5-da95999c5bb0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8905812-7e3b-4875-87b5-da95999c5bb0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "516355b6-65e5-4e7f-96cc-f5f66a86fee1", "name": "tr(r:p1rdt6528-p1rdt6528lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ef5115d-ad7b-4671-b984-b9fd5969bf61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d097d9be-dd3a-4616-a873-8ab5013c4e72"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d097d9be-dd3a-4616-a873-8ab5013c4e72"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "314abd89-9ffb-4e76-bde9-35cd4f3410d0", "name": "tr(r:p1rdt6530-p1rdt6530lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40ec7437-80f0-49e8-806a-c696b1402713"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4ee2d3a-e97c-4ec4-9fa0-d7db1b3e9253"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4ee2d3a-e97c-4ec4-9fa0-d7db1b3e9253"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1e893589-336e-4ed7-ae34-9ffb1e76b82b", "name": "tr(r:p1rdt6531-p1rdt6531lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "385eabe4-8c8e-4354-96ec-931e6c25574d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf4a2da0-682a-4119-b398-feaa6f5a8498"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf4a2da0-682a-4119-b398-feaa6f5a8498"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "aaf01e94-e631-4cbd-9b80-5dd82eae3e7f", "name": "tr(r:p1rdt6532-p1rdt6532lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9f12ed7-454c-4cc9-a631-377121a07ba5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0c3e71a-52a1-49b9-a899-c13d639ac0a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0c3e71a-52a1-49b9-a899-c13d639ac0a6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "16c6d40c-8621-46f3-a9d9-eb9f155486b7", "name": "tr(r:p1rdt6535-p1rdt6535lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b13053e-033e-4fe9-8eb3-89389e4bdc2b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10f0e9fa-75b8-4eaa-a2ad-b6a3fb4ae859"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10f0e9fa-75b8-4eaa-a2ad-b6a3fb4ae859"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "1636c5ab-0f83-47b9-b0b9-95c17d558f42", "name": "tr(r:p1rdt6536-p1rdt6536lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f5cda74-5e33-4c52-8b2c-76bcd5e6c5cb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b93e7299-60a4-49d6-9d34-885860588861"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b93e7299-60a4-49d6-9d34-885860588861"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "81e7d228-2f50-4e9c-a1a5-06c06422eaec", "name": "tr(r:p1rdt6537-p1rdt6537lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "902291fa-9561-4f40-a4b7-4fd9fdded417"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3f191ff-f8f2-4f13-af83-e67d1fdd366a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "a14a1967-2de3-44cf-b403-5c2c78717e13", "name": "tr(r:p1rdt6539-p1rdt6539lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9707f264-8f82-4483-8337-6c89d709faf7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b34f50ff-9a1f-439e-81a8-dfcee658926b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b34f50ff-9a1f-439e-81a8-dfcee658926b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "0982378f-fc34-40cc-8889-8feb46b3d3a3", "name": "tr(r:p1rdt6574-p1rdt6574lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25a9ec20-35b9-4262-a02d-cafa63e5ee42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a43920a-a200-40fe-b5b6-3cdba0c7e784"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a43920a-a200-40fe-b5b6-3cdba0c7e784"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "078928ee-8198-4b34-9e44-3d2464af89ec", "name": "tr(r:p1rdt6581-p1rdt6581lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "599c6ed9-5ff7-4c97-a469-adceecaaf902"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "608e485b-13ce-493b-be96-ab83ad733c92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "608e485b-13ce-493b-be96-ab83ad733c92"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "f15ffb13-3e9f-44b6-9603-dab244b5181f", "name": "tr(r:p1rdt6847-p1rdt6847lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e92b102-eaee-41cc-a2fc-c6c4b3bfb58b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7b9897e-b820-424c-adf8-7416de585357"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7b9897e-b820-424c-adf8-7416de585357"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "e3df7eb1-aff6-4359-acc7-d144d166201d", "name": "tr(r:p1rdt6848-p1rdt6848lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96399e51-1243-4e7f-ae3a-5e2c67123aae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94c9fa37-fc5c-4243-b0ca-f70840febaee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94c9fa37-fc5c-4243-b0ca-f70840febaee"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "d992636b-1b45-4cf4-9b69-e4a53bf53fdf", "name": "tr(r:p1rdt6995-p1rdt6995lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3741c9d4-d03a-4b2f-be57-52a8977351ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09a476ff-48a0-4d27-9cf0-c007e2e98acb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09a476ff-48a0-4d27-9cf0-c007e2e98acb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6973bac5-8bc7-4183-ac29-4d1c42f19e00", "name": "tr(r:p1rdt7015-p1rdt7015lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6278a0d-f5d3-4b11-aee9-3bb23f9954a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "536d7c56-85a6-4167-b4f6-2f39936cd662"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "536d7c56-85a6-4167-b4f6-2f39936cd662"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a0c75282-007a-41ab-9904-5fad1ba4ac01", "name": "tr(r:p1rdt7036-p1rdt7036lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52068090-b613-46d7-a31f-ad3ca26382d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a371c8b-1993-432c-b2c6-21b18bec27da"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a371c8b-1993-432c-b2c6-21b18bec27da"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "2d40d74c-19e5-4154-811a-bf6f0c3b4793", "name": "tr(r:p1rdt7038-p1rdt7038lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb3a9847-70d0-4004-95ef-63884c6c1cdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "046f6c53-8d9c-43a1-88ce-169ade9e9557"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "046f6c53-8d9c-43a1-88ce-169ade9e9557"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "57d5d60c-4bbd-4830-b62b-aef430bbbb13", "name": "tr(r:p1rdt7046-p1rdt7046lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9bb8596a-bcb2-4282-bf1b-9939a9af87d9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cd6a9808-9889-4f16-825d-c9763357c293"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cd6a9808-9889-4f16-825d-c9763357c293"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "88d0b3b4-df75-431e-a234-b9c4c40cd0f7", "name": "tr(r:p1rdt7054-p1rdt7054lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3cf406b-69e6-4aee-a6fc-272dad7693a4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf93e681-3ab6-4929-95f1-1da6d5dd28fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf93e681-3ab6-4929-95f1-1da6d5dd28fa"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9d5af3ee-6de8-428a-bce8-ff4ba5108c9f", "name": "tr(r:p1rdt7061-p1rdt7061lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75947ffd-3765-443b-bef8-b6af746ef624"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc33ade7-4471-40b8-8e9b-1846e0ad60e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc33ade7-4471-40b8-8e9b-1846e0ad60e8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "7b8e2373-7990-4ad0-ac7b-fea580be3edb", "name": "tr(r:p1rdt7067-p1rdt7067lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b470fa62-70d4-4cc5-8f7e-b9cda37481e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ff878e1-3143-4f8e-aa92-74d0a9046417"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ff878e1-3143-4f8e-aa92-74d0a9046417"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "c5a5b6ad-87d0-4856-83d7-f4e3fd1bf17a", "name": "tr(r:p1rdt7069-p1rdt7069lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aae22557-7d34-401d-82c9-2d2710ff2915"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a1566f1-7f0d-41d7-adad-425c9a344eb0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a1566f1-7f0d-41d7-adad-425c9a344eb0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "74945b57-66b3-460b-8963-4876d9317ea5", "name": "tr(r:p1rdt7070-p1rdt7070lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac6e8ccf-75ec-42e0-a3cb-9ab86e2731a4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "844bdc22-2e32-43ee-8e0b-26f3f4c107b8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "844bdc22-2e32-43ee-8e0b-26f3f4c107b8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "56ede37f-8654-4ee4-98d5-b4ca3c882a01", "name": "tr(r:p1rdt7075-p1rdt7075lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8cebb186-4d9e-4d2c-b0d9-100056d34942"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e0577c2-8275-4303-ad11-2c4f56df3f5c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e0577c2-8275-4303-ad11-2c4f56df3f5c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "3c44ca10-17d2-4bc0-8731-abfad4747034", "name": "tr(r:p1rdt7080-p1rdt7080lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "662e2a1c-9a54-4ac3-b478-98e3a478349d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d86bd7f-7759-4d74-9c74-d58010498f92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d86bd7f-7759-4d74-9c74-d58010498f92"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "23574f4e-125b-4c27-9e9f-edd96225a600", "name": "tr(r:p1rdt7087-p1rdt7087lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f614382d-3883-4f6b-b1f6-c8e83d84ee22"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d0c96fe-78c2-4303-ac5c-bbe440f19666"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d0c96fe-78c2-4303-ac5c-bbe440f19666"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "fe0147a8-371a-4e44-a456-842e99895e5b", "name": "tr(r:p1rdt7088-p1rdt7088lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac70c13b-5f4f-45f3-880a-b4b476ea552a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f1652e8-6cf7-43d4-8474-e61a74873675"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f1652e8-6cf7-43d4-8474-e61a74873675"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "49996ff9-e4f6-4f1f-abb7-8f8f1d042cb6", "name": "tr(r:p1rdt7089-p1rdt7089lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31cd4834-477f-4060-8efd-0504c8e8eaa9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73cfcce9-a925-4f29-9cde-6dd6f50735e1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73cfcce9-a925-4f29-9cde-6dd6f50735e1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "625b6c93-5baf-422e-bbe0-ac474e8c21b5", "name": "tr(r:p1rdt7090-p1rdt7090lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08d3a02a-555d-4ad1-9b13-d413b7a16eef"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d6a4c80-d261-4350-8224-8fe5191459c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d6a4c80-d261-4350-8224-8fe5191459c7"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c9e88619-7030-488f-8581-b184ead99804", "name": "tr(r:p1rdt7091-p1rdt7091lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6372a592-5e2d-41c8-819b-f56bfbb58e19"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0c42b48-7ca4-465f-b17c-048cb5f6d79b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "900a59fa-b9e1-4d82-96ad-d7a0e70edd73", "name": "tr(r:p1rdt7201-p1rdt7201lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f64ed4a2-6afb-447c-8c6b-15935e050a6d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6718b871-3967-4c29-83e5-441799c7fb92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6718b871-3967-4c29-83e5-441799c7fb92"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "ebdb125c-15f7-4ac7-8898-a0749c1a885a", "name": "tr(r:p1rdt7220-p1rdt7220lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a2f1a631-48f7-4291-9adb-588a66620ebf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d5e45d6-867a-4442-8258-2c04891dbc4b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d5e45d6-867a-4442-8258-2c04891dbc4b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "46e0dc9d-bf0c-4247-8399-4bba2bf59842", "name": "tr(r:p1rdt7224-p1rdt7224lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eeab7dfa-540c-4275-b159-f6ac4d1350f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d6a6156f-e72a-41f0-a307-e6030de24fde"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d6a6156f-e72a-41f0-a307-e6030de24fde"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c6728992-0569-4ad6-a2ee-a89c059a8cb9", "name": "tr(r:p1rdt7248-p1rdt7248lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a006c5f-e960-4ae2-a37f-d23d7b873a22"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2087cee5-9f6e-4400-8ca8-bbb120cd4dae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2087cee5-9f6e-4400-8ca8-bbb120cd4dae"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "c26eb6ec-9734-4824-8244-a225695d909b", "name": "tr(r:p1rdt7253-p1rdt7253lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f31b09da-e4cc-409e-9634-1907480039ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b4f7df4-5453-459d-8599-48fd5f29a9c6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b4f7df4-5453-459d-8599-48fd5f29a9c6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "13b3b35f-051e-4e07-9ad6-700afdf01778", "name": "tr(r:p1rdt7268-p1rdt7268lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a21680f1-33a7-44e1-9293-98c6861ba2a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1130272e-b98e-496f-aeb9-c094cf9cd824"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1130272e-b98e-496f-aeb9-c094cf9cd824"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "2bf5204f-ad9c-4982-ae22-74ef1aeca8c5", "name": "tr(r:p1rdt7298-p1rdt7298lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b658bf21-450c-4e6b-9dec-c5023a05fd19"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d304e5e0-2cc1-4167-9fad-6fc72228d828"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d304e5e0-2cc1-4167-9fad-6fc72228d828"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "8b3fc746-d9f0-45d0-ad16-d61574e7758f", "name": "tr(r:p1rdt7301-p1rdt7301lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84200441-4c26-4966-a4b7-6b91fb43f02e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43df4c14-a198-4d51-87f4-80000198cd47"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43df4c14-a198-4d51-87f4-80000198cd47"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f3cf9fd8-981a-45c4-8d3c-5f8be4e28074", "name": "tr(r:p1rdt7302-p1rdt7302lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a65c4d3-2fc6-48c8-b944-68c4229db3dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e2a141f-436a-45c0-9c15-179301a439c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e2a141f-436a-45c0-9c15-179301a439c8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "64a649e8-0397-468e-8602-656f8d0a2792", "name": "tr(r:p1rdt7306-p1rdt7306lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "607c7275-da9a-4620-b019-59a66e98c2e6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0926064a-1c87-450a-b282-23708de8aec4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0926064a-1c87-450a-b282-23708de8aec4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "0d51ff9e-3968-4c9c-b1a5-f15632d49f89", "name": "tr(r:p1rdt7307-p1rdt7307lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "231b5cf9-ec2c-47d1-aada-5454926561dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ce9dd2c-9e17-46b7-a6f4-e85077664432"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ce9dd2c-9e17-46b7-a6f4-e85077664432"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6a3a1abe-b81d-478b-9726-5826aada08d9", "name": "tr(r:p1rdt7311-p1rdt7311lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3a4dfb4-e1b3-43b9-ae42-b0cec47ff4ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2d6046b-9ece-4295-a180-41bf2ce47ce6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2d6046b-9ece-4295-a180-41bf2ce47ce6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9d5b01f2-1d26-4772-9ec5-58ed8abd8ee8", "name": "tr(r:p1rdt7313-p1rdt7313lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a3a5e1c-77a2-4a9d-89e0-7d1c94176787"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41e61263-feb6-4264-965a-fd1309d997a1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "34cd711d-2476-4079-bee1-db83e6e89155", "name": "tr(r:p1rdt7314-p1rdt7314lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0cf1844f-a32e-40f2-bc96-05fad3bdd88d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97844fdb-b016-4ca3-8777-b0553ead9297"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97844fdb-b016-4ca3-8777-b0553ead9297"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "92d3cf9e-563c-4377-b3aa-ebfc60ed645e", "name": "tr(r:p1rdt7318-p1rdt7318lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e86bc267-1607-4aa3-916f-ed826b0adfdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22b1ecce-d5df-4f42-abb2-9f4c3d3a28c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22b1ecce-d5df-4f42-abb2-9f4c3d3a28c5"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "0b6fafe7-545d-452c-b7f3-62b2c442f7dd", "name": "tr(r:p1rdt7550-p1rdt7550lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dead8520-e2f5-499b-9316-77780f9b1dfe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58be5cbe-5a7c-4fa5-972d-e03100b3bb46"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58be5cbe-5a7c-4fa5-972d-e03100b3bb46"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4fbe1b16-45a1-4f4f-b54c-4bd9dacab9b2", "name": "tr(r:p1rdt7551-p1rdt7551lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f0f3112-1395-48bf-88c1-8dd4b171478d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c4d7ee3-fc5d-4a17-a717-3d6b6d5a67ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c4d7ee3-fc5d-4a17-a717-3d6b6d5a67ae"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f6bb901b-e888-474e-937e-b47c34f55eec", "name": "tr(r:p1rdt7552-p1rdt7552lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db899c48-a801-4f83-b59d-e587ba80019d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f5d6708-cef4-4aac-9fa0-c738953c788f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f5d6708-cef4-4aac-9fa0-c738953c788f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9ef9d653-e17c-46b4-b8eb-308dcc2d2329", "name": "tr(r:p1rdt7553-p1rdt7553lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddf629eb-ea60-4fce-b731-7ebb33665829"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7a672b2-d127-4fb5-8cc4-8115b8ef3f60"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7a672b2-d127-4fb5-8cc4-8115b8ef3f60"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "1ad1e6cb-ac02-4298-94d9-b6e7b217363f", "name": "tr(r:p1rdt7554-p1rdt7554lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f6de990-0988-4126-86ca-d1fd72c555fe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86a6d184-d883-4e27-aee5-b89c82163284"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86a6d184-d883-4e27-aee5-b89c82163284"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "bd4532f5-197c-4d9d-88b6-69e85596cebd", "name": "tr(r:p1rdt7555-p1rdt7555lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0075333-98fe-4ee8-bb64-a18119b817c0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0de9c581-b78b-44d6-8693-59b995e2a3bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0de9c581-b78b-44d6-8693-59b995e2a3bb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6236b757-e2d7-4dc9-9418-64e399e056c9", "name": "tr(r:p1rdt7559-p1rdt7559lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f239ef4e-83f0-4a2c-ada3-8e30cef38472"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b593ec6-e1e3-48c2-b352-f7966f206aa9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b593ec6-e1e3-48c2-b352-f7966f206aa9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1d28deb4-7339-4686-a9aa-b3814787aab1", "name": "tr(r:p1rdt7561-p1rdt7561lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc6bd64f-1ad3-4bd9-b590-7d4b673a94b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05e30abd-3c40-4dbd-9261-ca8a8abd9c56"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05e30abd-3c40-4dbd-9261-ca8a8abd9c56"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "bb32295e-91d3-4b0d-a30b-f527438019eb", "name": "tr(r:p1rdt7564-p1rdt7564lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa33ca9e-e16d-4c49-8a70-c6c30cf7b038"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7588b3b-f54c-483d-b354-b9908483019a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7588b3b-f54c-483d-b354-b9908483019a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "38f3f4b0-05b8-469e-9bf4-9aa64b723b84", "name": "tr(r:p1rdt7570-p1rdt7570lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9b94106-b7c5-4ce9-9c19-053487848c2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2b3b9e1-3d98-44c1-bd38-9325623a1553"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2b3b9e1-3d98-44c1-bd38-9325623a1553"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c839a693-631e-43a1-943f-063d3e8cac8a", "name": "tr(r:p1rdt7572-p1rdt7572lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4307e78-304a-4175-8e81-9cb23d99f394"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69bf048e-54cd-4e41-a23e-485b0cd98fae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69bf048e-54cd-4e41-a23e-485b0cd98fae"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "14f1f8fd-687c-4967-a86b-790552e9bb2b", "name": "tr(r:p1rdt7574-p1rdt7574lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd487832-bc77-406f-a995-4b099fad7c64"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a742708-0f8b-42d0-a977-b5ce5e36a042"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a742708-0f8b-42d0-a977-b5ce5e36a042"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "40be45f1-06bb-4504-b1e8-03427c7e92c8", "name": "tr(r:p1rdt7576-p1rdt7576lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b28595b-dcbe-4d1b-92c4-94acf370bb1f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56b05024-7907-458d-a5c3-0e54ffbabdb5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56b05024-7907-458d-a5c3-0e54ffbabdb5"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a60ca7e5-fadd-4a55-9aaf-a6336c346d87", "name": "tr(r:p1rdt7579-p1rdt7579lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76f6a27f-0e4f-48b8-9dbd-31c6ffc4ec75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d00b7fe-0384-4c12-a0cf-8895458d3b80"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d00b7fe-0384-4c12-a0cf-8895458d3b80"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "dd238be0-3718-42e1-a1c0-47e911dee99f", "name": "tr(r:p1rdt7588-p1rdt7588lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f2dabc2-0b52-490c-b13a-32c268f6bd33"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abc940b0-c9f5-4582-adaf-ad7f4a79a35f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abc940b0-c9f5-4582-adaf-ad7f4a79a35f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "306bd8de-2bed-4392-b5cd-af1639de22f7", "name": "tr(r:p1rdt7589-p1rdt7589lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f9809eb-41e0-40a8-b43a-93556f767f68"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53e9cf92-1c91-428f-bdff-64257257ad5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53e9cf92-1c91-428f-bdff-64257257ad5b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "76c04b04-3f7a-4a92-8244-2b76e218fa05", "name": "tr(r:p1rdt7598-p1rdt7598lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f95e5fa5-a84c-42a4-b519-8d344e816ecd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff1e0d26-d845-43c3-9aaf-01d1c007b9a1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff1e0d26-d845-43c3-9aaf-01d1c007b9a1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b1a1407b-f572-4475-89dd-fdc7487a6303", "name": "tr(r:p1rdt7599-p1rdt7599lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a086b782-3a8d-44e9-9948-cb7f051219e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d838502-3769-4d70-839b-26fd628ce478"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d838502-3769-4d70-839b-26fd628ce478"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "be508024-b14e-4860-a815-fba0b7e63239", "name": "tr(r:p1rdt7605-p1rdt7605lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e36f1f1-6993-46b0-bafa-9530fd1652ef"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3488ff0-696f-4180-bc70-41ff37f9c365"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3488ff0-696f-4180-bc70-41ff37f9c365"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ab99af7f-f37b-440c-88b1-ff14dfa3d7c1", "name": "tr(r:p1rdt7612-p1rdt7612lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3410d88a-3e9c-427e-a79e-5c602455ed1d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fdfea70-187a-4bbc-ba3f-69cb74c4d5c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fdfea70-187a-4bbc-ba3f-69cb74c4d5c5"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "5633eb80-82db-48b3-b73b-40e06940ca5c", "name": "tr(r:p1rdt7615-p1rdt7615lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "105df8ff-ec38-4cd6-b557-c318b4023bd0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "269e9ba5-bc54-4cbd-9140-4b1bea74fc53"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "269e9ba5-bc54-4cbd-9140-4b1bea74fc53"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "20e0b0a7-7df7-4a70-90c4-c2e51e42f8d2", "name": "tr(r:p1rdt7616-p1rdt7616lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7167a2e-9e83-441e-a15b-0256848c3f6d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6af13868-ecb1-4110-be3f-537741287035"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6af13868-ecb1-4110-be3f-537741287035"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "ab1caeed-4f38-4dd1-8946-e1f37a4e07cf", "name": "tr(r:p1rdt7617-p1rdt7617lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01c9d31d-c3bb-4950-9bbd-00377c252ddc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4be4af94-fee7-40d6-9061-9a0fe0e7377e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4be4af94-fee7-40d6-9061-9a0fe0e7377e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "48f92b1a-dfcd-45a9-a9c8-46f9c5a3464f", "name": "tr(r:p1rdt7618-p1rdt7618lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0fef9b3-a4bd-421c-8a54-cbf6f44c460d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49f37435-54fc-42b4-baba-94f0611c8c76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49f37435-54fc-42b4-baba-94f0611c8c76"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9ba2159e-0ded-4752-ab15-e81614b1a3f6", "name": "tr(r:p1rdt7619-p1rdt7619lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "161d6f3b-8bd9-4fa8-9442-c6ff008e8d3d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a205379-48f9-444c-baf8-dc84fc9c6d8a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a205379-48f9-444c-baf8-dc84fc9c6d8a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ceab5e31-ac40-491f-8469-d2987e18c247", "name": "tr(r:p1rdt7620-p1rdt7620lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97be7ac3-a710-4de8-a666-276813582cd6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af91c50-929d-4ac6-9272-7c44d17a0094"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af91c50-929d-4ac6-9272-7c44d17a0094"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "bdcbb6b6-4e44-48e9-8d5b-4602c5816566", "name": "tr(r:p1rdt7621-p1rdt7621lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa48cf27-3b07-4460-ad9c-8d9862238645"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60f0bddf-6e4b-495c-a98d-f3940d69a5e9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60f0bddf-6e4b-495c-a98d-f3940d69a5e9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "654c6e8e-e5cc-4433-b8a9-4f1e0ff9afb9", "name": "tr(r:p1rdt7624-p1rdt7624lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e240270-762d-49f0-a4e4-29fcd6273ce5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e2075fb-9691-447e-9a73-f88649310bc1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e2075fb-9691-447e-9a73-f88649310bc1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "3e444053-e0f6-4c5e-b83a-778c710b6246", "name": "tr(r:p1rdt7625-p1rdt7625lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3e6cbe9-d1d3-4c59-981f-dad980f0999b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6b1e3b6-ce3a-4ad6-a046-6608530b2ec2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6b1e3b6-ce3a-4ad6-a046-6608530b2ec2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b3029529-3d87-4bf6-855d-9e4acc2459cb", "name": "tr(r:p1rdt7626-p1rdt7626lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56d67e3e-46af-4e2c-86a8-191d97b0ce8a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56f8eed1-77ae-4d65-80aa-7ae148350333"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56f8eed1-77ae-4d65-80aa-7ae148350333"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9123f9a8-9439-48d0-8966-b3c4d4d710e1", "name": "tr(r:p1rdt7627-p1rdt7627lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5bddd75e-1974-41ee-ab51-625c7485a573"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90d8891c-6e6d-46b9-8f88-acc9453c6541"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90d8891c-6e6d-46b9-8f88-acc9453c6541"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9afa56ce-eb98-472e-a5c6-91206e1a8521", "name": "tr(r:p1rdt7630-p1rdt7630lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "723e2b5c-414c-4f3d-ba23-d2df4bc63e75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ad2599f-313b-49c6-abaa-19177e1a9edc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ad2599f-313b-49c6-abaa-19177e1a9edc"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b9fc1aba-239f-4d0d-8085-2dd63d6da04b", "name": "tr(r:p1rdt7631-p1rdt7631lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9e53141-a773-4127-9558-3887070a8f36"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4861056b-b634-4900-94bb-d6c995387351"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4861056b-b634-4900-94bb-d6c995387351"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "752c4be4-3b4b-44b4-ae38-4efa162ae539", "name": "tr(r:p1rdt7632-p1rdt7632lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36e7cd28-6795-41d5-847d-92347871384f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7235cf3a-dd26-47f7-884c-6335024a3064"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "e911abc7-52f8-4093-a459-c3ca4018ece3", "name": "tr(r:p1rdt7699-p1rdt7699lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec849ee4-3d69-46a9-9a2a-242a3943e46c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bfa76dc8-4007-4e52-9692-2eec7cb574e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bfa76dc8-4007-4e52-9692-2eec7cb574e0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f4c59d36-a424-406c-abe0-7ec431462ff8", "name": "tr(r:p1rdt7701-p1rdt7701lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "74968ebc-53c5-4fc6-8172-3ffa9dea7683"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0cc95d09-c799-488e-81e8-50326a7da1ea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0cc95d09-c799-488e-81e8-50326a7da1ea"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "76f31e46-6028-4e28-9c78-d861c071c648", "name": "tr(r:p1rdt7704-p1rdt7704lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02ea9067-6a2a-48b6-b5f1-10992b9fbd77"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ef392d6-b408-4a7f-8a67-9fe43e1df582"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ef392d6-b408-4a7f-8a67-9fe43e1df582"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "aded564b-854a-4916-b3de-3ee4098f53f2", "name": "tr(r:p1rdt7712-p1rdt7712lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4462b9c6-748f-48e9-9ff9-7f20a06cf456"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59a62487-c709-428e-9e97-c7c285a1305c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59a62487-c709-428e-9e97-c7c285a1305c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ac1905ca-2d2b-4806-8ad1-5ac7cd2f4526", "name": "tr(r:p1rdt7718-p1rdt7718lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "048e2bab-67f2-4975-81a1-bbc9f2f9cd88"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6d10a4e-e7bc-4448-bca3-a5f2117b6198"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6d10a4e-e7bc-4448-bca3-a5f2117b6198"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a39660fd-d276-4af3-afe6-1cd2ff97fa07", "name": "tr(r:p1rdt7735-p1rdt7735lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62078787-3ae2-47b3-8f67-8e89e110c8be"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96dcd934-01a0-4719-89bc-a18430edf179"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96dcd934-01a0-4719-89bc-a18430edf179"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "ce2cab85-3bda-4e0e-9cbc-d2bea2fe03e1", "name": "tr(r:p1rdt7790-p1rdt7790lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97198258-8ba3-4950-8747-3241c6a4fcee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ed564b5-8d49-4ff7-94c2-b245981472e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ed564b5-8d49-4ff7-94c2-b245981472e8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c43106ec-5430-410d-a310-0f90dbe8b582", "name": "tr(r:p1rdt7954-p1rdt7954lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21e15d54-eab8-4204-9ed6-407fd8684700"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9dd5bb5-1410-4635-8a85-d23d7c3e55ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9dd5bb5-1410-4635-8a85-d23d7c3e55ad"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9cba1db2-bbe9-438b-a0ae-cbe9c6042c84", "name": "tr(r:p1rdt7973-p1rdt7973lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "016e4575-cd41-4993-be9b-5e5236a139ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3a96167-4b09-49c9-baf7-4fb588ecb002"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3a96167-4b09-49c9-baf7-4fb588ecb002"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "73995ff5-d40e-411d-80e1-03503328178f", "name": "tr(r:p1rdt7983-p1rdt7983lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e261b565-1f57-4cdc-bdd6-e045ee55d290"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb63be48-94ec-4c9f-9991-77892e14171b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb63be48-94ec-4c9f-9991-77892e14171b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "ee7e1b81-29bd-4324-bd7f-edb721cfe6d1", "name": "tr(r:p1rdt7986-p1rdt7986lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "93a5388e-ffd7-403e-b6cf-26b7e81feed1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "415fe6e9-953e-40f6-8ae8-43834e4e6ce4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "415fe6e9-953e-40f6-8ae8-43834e4e6ce4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "40ae26e7-8612-4ca1-af9a-6138c75b525a", "name": "tr(r:p1rdt7988-p1rdt7988lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48e4b67a-0a47-48f0-b787-0a639db89caa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94f12107-697c-4278-95e0-32b6eb49fdb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94f12107-697c-4278-95e0-32b6eb49fdb3"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "68d17fd2-4b36-4948-b180-d122e210a188", "name": "tr(r:p1rdt8012-p1rdt8012lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bfb33cd-0cf1-455d-81e7-3d0472fa1b41"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5b22c57-7912-4e9f-9b06-6a8ff706a58d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5b22c57-7912-4e9f-9b06-6a8ff706a58d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "4d09727b-7ad9-4895-b375-82bcd4bbeee8", "name": "tr(r:p1rdt8015-p1rdt8015lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc543f54-740b-4a7f-b1c5-eb3783a8ade0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6c5d7ff-cfcd-4b30-98db-eb44a95d6841"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6c5d7ff-cfcd-4b30-98db-eb44a95d6841"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9312b2f6-1773-4a40-bf4a-1a6db143517c", "name": "tr(r:p1rdt8034-p1rdt8034lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f83d22a-fa1e-4a4e-aab9-a9dea8ee06e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "972fe574-f88e-4a8d-8845-d5baa2f378a7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "972fe574-f88e-4a8d-8845-d5baa2f378a7"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "67d378fb-5a38-42c9-85a2-d6c5d30de182", "name": "tr(r:p1rdt8149-p1rdt8149lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b706c56-20f1-49ed-9cbe-0ec1491b83e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9951633b-4311-4ca2-9316-3801be13fe97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9951633b-4311-4ca2-9316-3801be13fe97"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b0592825-0ebc-47eb-b648-6b5e9eca65f6", "name": "tr(r:p1rdt8150-p1rdt8150lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78081763-07d2-4989-b492-e1c5178c4097"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cd1ae47-6aaa-4b57-ba44-1e74f6ea54b7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cd1ae47-6aaa-4b57-ba44-1e74f6ea54b7"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d471ae12-2ba6-4052-a460-048edfdc8258", "name": "tr(r:p1rdt8151-p1rdt8151lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c794942-d5ce-481f-9c6a-563a2180a4ba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a8deb5-b46b-4d4c-876c-b44b2258a6fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a8deb5-b46b-4d4c-876c-b44b2258a6fa"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "49759203-777f-49ae-b598-ca28caffe71e", "name": "tr(r:p1rdt8153-p1rdt8153lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b44d5021-4fdb-4618-bcb2-237ecf2e10e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a542ca5-b24e-44dc-8b68-c00aa024afad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a542ca5-b24e-44dc-8b68-c00aa024afad"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a7da70e8-efbf-4e0b-a7f7-eeb682445e70", "name": "tr(r:p1rdt8154-p1rdt8154lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42ab6054-1866-49c5-b2ab-3cf27199c1c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32fefbef-e10b-4758-8c2e-ccafad49aa5d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32fefbef-e10b-4758-8c2e-ccafad49aa5d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "cdab182b-63a8-43ed-a657-4a881f34363d", "name": "tr(r:p1rdt8155-p1rdt8155lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1613a53e-5194-4d26-b83b-475d9f02a32c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51812cd8-eec8-4862-8413-d25a7e9862dc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51812cd8-eec8-4862-8413-d25a7e9862dc"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "8e5d5e35-2a37-4ca3-b6d8-ac657a25cc53", "name": "tr(r:p1rdt8157-p1rdt8157lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a30e197-897f-4516-b4e5-f70081e6f8c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa6d4429-8a95-4ebd-9e3a-9867734245bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa6d4429-8a95-4ebd-9e3a-9867734245bd"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9c6e09ab-62cf-4cf2-ad4b-85f28da49b1b", "name": "tr(r:p1rdt8159-p1rdt8159lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42b9c576-ddba-4be1-bc64-a37d8cbdfa84"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1dd4660-3cd0-4709-b1ef-1c598e5e39fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1dd4660-3cd0-4709-b1ef-1c598e5e39fb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "4e23e836-b3c0-414d-8b6b-35675ebd0a0a", "name": "tr(r:p1rdt8160-p1rdt8160lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38b72c12-2e2f-4d83-8f5a-9d8503dc29eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "232fed6b-fe0f-4a44-93e9-e6675b50c39c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "232fed6b-fe0f-4a44-93e9-e6675b50c39c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "36e7363c-1995-4a3a-86c5-a0ace2ea4bd8", "name": "tr(r:p1rdt8161-p1rdt8161lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25946c74-15c2-412c-baed-8de5f7aecf98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac7e489e-7249-4702-9ed6-131cad34500f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac7e489e-7249-4702-9ed6-131cad34500f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "ce00bda5-ef31-4200-abe8-7edb6e2ce469", "name": "tr(r:p1rdt8346-p1rdt8346lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14b429c3-41da-4123-b661-40cbdfaf33e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9560197a-21d1-4601-8bcb-213df4844f4a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9560197a-21d1-4601-8bcb-213df4844f4a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "e76e538a-44eb-4381-8e37-7fb09b2f63a2", "name": "tr(r:p1rdt8405-p1rdt8405lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60829dab-c129-4017-961a-81435d8afa93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "408d5d7b-fc71-46bb-8de0-2d4e628c29b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "408d5d7b-fc71-46bb-8de0-2d4e628c29b6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d7e934e2-03f8-4a6a-ab5d-ad3b3dd48470", "name": "tr(r:p1rdt8408-p1rdt8408lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28af960e-6f27-483a-8029-0c5f1641f51d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3fe0f77-a7c1-48e3-94aa-30b69f20ca65"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3fe0f77-a7c1-48e3-94aa-30b69f20ca65"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "95aaee68-75c3-4a09-afe8-2ae7e6764680", "name": "tr(r:p1rdt8414-p1rdt8414lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b48f78d-1092-4536-bfb3-029da6a70dff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fca92353-c013-4c41-8507-ec8704410834"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fca92353-c013-4c41-8507-ec8704410834"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "2a2e6bf5-cdb1-4881-a7ba-b0751befd246", "name": "tr(r:p1rdt8422-p1rdt8422lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ce65512-7d5f-4514-b55c-1775e80dd94d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfe35c35-8164-4825-81e3-10a2ece2cb27"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfe35c35-8164-4825-81e3-10a2ece2cb27"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "704a77eb-97a5-44a1-ab78-f3e5768a865c", "name": "tr(r:p1rdt8434-p1rdt8434lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f28de397-0db4-486a-8ce6-9f65c68703b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdc5ef2a-c0d0-4702-b6c6-df08af1e8746"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdc5ef2a-c0d0-4702-b6c6-df08af1e8746"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1ccbc567-041b-40ab-b2c1-6da64ae2a300", "name": "tr(r:p1rdt8436-p1rdt8436lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fcc42825-2690-4965-a99b-e78285a9b84e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b24c9345-625f-499d-96cf-30b2de5839b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b24c9345-625f-499d-96cf-30b2de5839b6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "db06099d-51cd-4922-8556-5fc046213ce9", "name": "tr(r:p1rdt8439-p1rdt8439lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07f340ca-58c2-4331-8265-a39a45c87b75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a38f544-e250-4fc9-942c-946c5cde0a33"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a38f544-e250-4fc9-942c-946c5cde0a33"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c1cf0331-e671-4257-a481-22857029dcff", "name": "tr(r:p1rdt8440-p1rdt8440lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bbfe31b1-38ce-4ae4-9143-bf08c81617e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "049362b4-49de-4e80-921e-ff763aaab2d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "049362b4-49de-4e80-921e-ff763aaab2d1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "bb01e69d-d66e-4622-a9d2-49439101442f", "name": "tr(r:p1rdt8441-p1rdt8441lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b423745-cc70-4c3a-adb0-f648170b4ab1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72c8f08a-0ba5-413e-a805-f9436b41ff29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72c8f08a-0ba5-413e-a805-f9436b41ff29"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d9636448-6ac3-4dab-b534-39f3b2189242", "name": "tr(r:p1rdt8442-p1rdt8442lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6700763-e6dc-4626-ac2b-22985f0043be"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b5ae28a-95f8-4023-aa23-36809fe96b10"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b5ae28a-95f8-4023-aa23-36809fe96b10"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "f401dbb6-1c00-4683-a97f-240f0d404ec0", "name": "tr(r:p1rdt8444-p1rdt8444lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "685fbdbf-47af-4cc2-97ce-354dd04ce915"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "978920e8-edf9-4bee-85f9-45f4081ed0ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "978920e8-edf9-4bee-85f9-45f4081ed0ca"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "e78e59b0-1628-44f3-9f40-434870c7485b", "name": "tr(r:p1rdt8445-p1rdt8445lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc0ee90f-1f9e-435e-bac4-86a4688c48fc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e0923da-550b-479f-b3d8-3e0320db6701"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e0923da-550b-479f-b3d8-3e0320db6701"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ba075575-7d34-4581-bd89-580a7809f865", "name": "tr(r:p1rdt8447-p1rdt8447lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13b8cfc1-d8eb-4f47-b024-c1daacf3771d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5dbc3459-6a17-4075-899a-6aab16fb3ab7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5dbc3459-6a17-4075-899a-6aab16fb3ab7"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "68fa5476-e1d3-4fcb-aae1-82554760837b", "name": "tr(r:p1rdt8450-p1rdt8450lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "184f95d4-cde1-4bf1-8a74-ebc7097cb10e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b4216c8-9e99-446c-ad09-5a09f046dd59"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b4216c8-9e99-446c-ad09-5a09f046dd59"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "832c98de-e0df-4a23-a77c-8bae8f9c82a2", "name": "tr(r:p1rdt8456-p1rdt8456lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0089e5ea-d706-4a74-812f-654ae73eabcf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d094b779-ebcc-4837-9ccb-31808e2a544b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d094b779-ebcc-4837-9ccb-31808e2a544b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f1be4587-95df-49ac-b27e-27bf9042374d", "name": "tr(r:p1rdt8458-p1rdt8458lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "433162b1-2a9b-4187-ba28-ec57503d76f6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e597d8da-e876-44a5-a109-1ce84527c557"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e597d8da-e876-44a5-a109-1ce84527c557"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1be9aa15-7b2b-40a1-9e35-67939a2032bf", "name": "tr(r:p1rdt8470-p1rdt8470lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "442de065-9e2a-4ff8-9100-1298d3fe0f6f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "edb15d92-f98a-4fa2-8129-ad8a39e0dc0c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "edb15d92-f98a-4fa2-8129-ad8a39e0dc0c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "978ee383-d478-4f12-a155-7192f5c3a6c6", "name": "tr(r:p1rdt8490-p1rdt8490lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37c41a4b-e439-42a1-b9a7-0582c528f0e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a84e1424-7faf-4077-9461-b39460f10ef0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a84e1424-7faf-4077-9461-b39460f10ef0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "eb250ab0-b078-4fd6-890a-38d97425c873", "name": "tr(r:p1rdt8492-p1rdt8492lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "307d9c6d-d5ee-4490-95d3-5a9b1d171e54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "127e4cc7-6413-4482-9ec3-40f8bde02d0c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "127e4cc7-6413-4482-9ec3-40f8bde02d0c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "325e4fe1-dddd-4f95-bd62-a4992948ea11", "name": "tr(r:p1rdt8802-p1rdt8802lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26ccaeff-3a34-4835-8906-1145148549c6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95a1a7c7-6055-47c9-a742-c1b81f6c7478"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95a1a7c7-6055-47c9-a742-c1b81f6c7478"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "7e8bf118-8d3d-438f-8fad-151a16e1fcba", "name": "tr(r:p1rdt8805-p1rdt8805lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3444af6b-f9d4-4229-b6b2-2114300c3f94"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "715c92fa-2470-4869-8d5f-0b4f3f8360d4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "715c92fa-2470-4869-8d5f-0b4f3f8360d4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "32c72906-a147-498a-a113-be950d59104f", "name": "tr(r:p1rdt8898-p1rdt8898lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d887dbc-43bd-413e-8e72-5c95a2ed0be8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6ff626c-d2fc-4b97-9013-4fd544d946a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6ff626c-d2fc-4b97-9013-4fd544d946a2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "ef3714fd-edab-4865-a2ad-4ee8d9fde607", "name": "tr(r:p1rdt8901-p1rdt8901lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f23ab51c-56f3-4421-b66e-7cdcf109787d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d53c0a2-78cc-4988-85a4-884ef039f5fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d53c0a2-78cc-4988-85a4-884ef039f5fa"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "955c5326-6c66-4d62-bf37-292638de7f37", "name": "tr(r:p1rdt8902-p1rdt8902lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f44ec9b-338a-4ae1-a26b-26422f218c13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d1c8eb9-7f79-49ad-9e93-6c7cdcc95e22"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "1ee50b0d-7af3-4a06-b0ea-4bc31090e03c", "name": "tr(r:p1rdt8904-p1rdt8904lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2edd17c2-6dfb-4f86-8998-b90a99755e96"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e111e213-bcbe-42c4-b6ab-2c734ff5341c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e111e213-bcbe-42c4-b6ab-2c734ff5341c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "90046b1e-ffaf-44e0-87b3-cb95655e8345", "name": "tr(r:p1rdt8905-p1rdt8905lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "924fc042-6ddc-484b-b09f-c65b35817d25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2777cc-f3fd-491f-a10b-4ed381cb948d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2777cc-f3fd-491f-a10b-4ed381cb948d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "eec52181-4f73-420b-8698-07ba3d2a5ba4", "name": "tr(r:p1rdt8911-p1rdt8911lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26613f51-86bf-4ae1-86c0-f23e48cf606e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c306f79a-0240-465e-a486-d0f11614fc57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c306f79a-0240-465e-a486-d0f11614fc57"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "63095410-c01a-4602-bc80-e104ffc07c8f", "name": "tr(r:p1rdt8915-p1rdt8915lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "361385c6-bb6d-4bbc-ab7d-4a5774e03d82"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2fbbca23-6473-4344-ac2e-cc97078b3d8d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2fbbca23-6473-4344-ac2e-cc97078b3d8d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "40e3269c-7a28-4e20-9fa3-df93e3a99468", "name": "tr(r:p1rdt8916-p1rdt8916lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "adcc33f8-72a3-434c-a021-6c5973713a91"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d268e33-708d-4bae-8348-cad27fd0d81a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d268e33-708d-4bae-8348-cad27fd0d81a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "e40cccd7-b398-4341-a909-7d8cef79eb67", "name": "tr(r:p1rdt9075-p1rdt9075lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "907828f5-8e26-41c4-8fbc-a3744608181a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6752e8f4-9e37-476d-aec2-4a2fe7c1e2dc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6752e8f4-9e37-476d-aec2-4a2fe7c1e2dc"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "adc3a07a-82a2-4e00-a6c8-1099bb4e0b40", "name": "tr(r:p1rdt9076-p1rdt9076lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2ce5116-c4f0-4ac7-a34f-3ba44c99d04b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdd64386-e256-47f8-8cef-1c933f993a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdd64386-e256-47f8-8cef-1c933f993a29"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "8f50d2c0-fc10-4b59-b588-c78fee9366a5", "name": "tr(r:p1rdt9077-p1rdt9077lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b7f2f09-976a-45da-8186-229aeedeb689"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b83eaaa-a092-42ca-a746-db4d9658d62b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b83eaaa-a092-42ca-a746-db4d9658d62b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "7ecefea9-516a-4cb1-8c06-cac3a09bcc5e"}}}}, {"uuid": "557e8429-9e93-4160-bcc4-3af879a36ea8", "name": "tr(r:p1rdt9084-p1rdt9084lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4251587d-600f-40a0-9aec-229fb2e3f2df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f0e4f59-8a46-4abf-9f06-e0383a59a45d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f0e4f59-8a46-4abf-9f06-e0383a59a45d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "eec76648-0280-4fe0-af8d-9f996d84c74a", "name": "tr(r:p1rdt9085-p1rdt9085lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7fcdf409-885c-4c95-834e-988842ed3f5c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "565bbfb1-a28f-4db2-be48-cbd58972025a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "565bbfb1-a28f-4db2-be48-cbd58972025a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "b66392de-bea5-4d55-91a6-d82ab4d1b213", "name": "tr(r:p1rdt9089-p1rdt9089lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b4ec275-bea8-45f2-94cb-5e24e82179d8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8108ac8-2807-4a40-85c2-db21efaadadb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8108ac8-2807-4a40-85c2-db21efaadadb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "ed549b0d-f520-47b7-a35d-6cd2a3169d35", "name": "tr(r:p1rdt9090-p1rdt9090lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52c72b52-1c6c-46f6-adbe-1054eb233c20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fc84159-09b1-4ca9-9a7a-a4fecab19f83"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fc84159-09b1-4ca9-9a7a-a4fecab19f83"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "dd3d2dc6-ddf3-4f3b-80f3-cdfaa7eee7d2", "name": "tr(r:p1rdt9091-p1rdt9091lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "563c6bb3-d8ed-4fce-ad66-3892426248df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e93ea18-150d-4d80-bac7-f3e1b87c5b4e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e93ea18-150d-4d80-bac7-f3e1b87c5b4e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "fe126484-9dac-44a4-b9a7-d0b95131a9d9", "name": "tr(r:p1rdt9093-p1rdt9093lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c29179f3-0b4e-449c-8562-a8fcb675be6c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f0726b7-3050-4c78-9c06-b9fd0c863ff3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f0726b7-3050-4c78-9c06-b9fd0c863ff3"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "658d959f-56a4-46f3-9c64-ca76eaf73c1e", "name": "tr(r:p1rdt9264-p1rdt9264lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bdf3994-bb0c-44f4-b1ea-ab29e73bd39c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c01a9b2-b002-4279-905e-950452f64f32"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c01a9b2-b002-4279-905e-950452f64f32"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a17c260a-bae1-4173-8fee-fc9ea0a4b0f0", "name": "tr(r:p1rdt9265-p1rdt9265lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b336e76f-17f3-4f5d-ba84-f24c3a4e3eed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "77d62813-61d3-4afd-9f21-869e2ea23e17"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "77d62813-61d3-4afd-9f21-869e2ea23e17"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "c682f3a2-335b-4876-b3f3-f17e582fb5fb", "name": "tr(r:p1rdt9266-p1rdt9266lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fbb2bd0-d109-4248-85f3-266fe479677f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78278589-be2d-4d99-9c03-92c221348917"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78278589-be2d-4d99-9c03-92c221348917"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4d59ae8b-6777-434b-8467-62a8e2a3f6f4", "name": "tr(r:p1rdt9298-p1rdt9298lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61ba1001-8b9d-481c-b205-45c6e0beadc1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "208f222c-45db-445f-ba0b-a4a195ca68a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "208f222c-45db-445f-ba0b-a4a195ca68a6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "bf58b1a3-eb94-4a84-8bf6-222f3696dfcb", "name": "tr(r:p1rdt9302-p1rdt9302lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4a41fe9-62ce-45ba-abcd-086ba429baa0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180fad26-0e7d-4e2c-ba17-c8e3315ca278"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180fad26-0e7d-4e2c-ba17-c8e3315ca278"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "3276927a-5d0f-4e74-818b-d91b6f65ebdd", "name": "tr(r:p1rdt9310-p1rdt9310lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3035d22c-c39f-4f07-9fe9-29888b16057d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4940a0e-dcc2-45fb-baa9-aadc84f8e882"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4940a0e-dcc2-45fb-baa9-aadc84f8e882"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "daf94052-bd8a-473d-8d00-900a40a66ce6", "name": "tr(r:p1rdt9311-p1rdt9311lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7011f1dc-1e7d-4961-9a23-620b7f5737af"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9e0aa7d-9097-4370-8f5e-52a5885da85c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9e0aa7d-9097-4370-8f5e-52a5885da85c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "31a8d47b-fb37-4710-af26-3c40bd619792", "name": "tr(r:p1rdt9312-p1rdt9312lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8721684-5439-482c-b8e5-be330d3cf745"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a21f5ca-51ef-4f81-8229-163182f011cf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a21f5ca-51ef-4f81-8229-163182f011cf"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b6d6629c-ebae-47e9-826d-42a5addc585d", "name": "tr(r:p1rdt9314-p1rdt9314lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d25f8d60-8aa7-4975-96dc-eba7696fa8ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3df13d91-365e-411b-917d-b28df5989280"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3df13d91-365e-411b-917d-b28df5989280"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "3f1254d8-6ad4-49ed-91f4-40f1125f1d3c", "name": "tr(r:p1rdt9316-p1rdt9316lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "644c5887-31f1-436c-bbf6-dae5a70743a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c97a99f-545b-49cd-b1fe-4fd9e04bf37f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c97a99f-545b-49cd-b1fe-4fd9e04bf37f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "26117ef4-73d0-4826-814c-c5b074c7979d", "name": "tr(r:p1rdt9333-p1rdt9333lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0da91bf8-b687-47df-a7dc-41e6166fd667"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a68a1c01-a04c-4af6-b1c8-02ddd1d67e0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a68a1c01-a04c-4af6-b1c8-02ddd1d67e0b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "a951a707-992b-4291-83f8-194955fad7e9", "name": "tr(r:p1rdt9377-p1rdt9377lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61972a50-ce24-4ec1-8535-402665b55a55"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e98299cb-8bad-49ea-8627-f3cfe01b9e23"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e98299cb-8bad-49ea-8627-f3cfe01b9e23"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "9d097eb6-0536-4329-9e47-689931548ec9", "name": "tr(r:p1rdt9381-p1rdt9381lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5791345-57dc-4f54-ab54-ea63e6a54ee0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e37f182-5a60-470d-8f5b-ba145cc27973"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e37f182-5a60-470d-8f5b-ba145cc27973"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "bb2e720c-aead-4e23-990b-b5d38b5fc81c", "name": "tr(r:p1rdt9384-p1rdt9384lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6eb9c7a5-5ab1-4d9b-a59e-538b68ad0bb9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abd09ea6-221c-47d9-beec-1062e0dd4aa7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abd09ea6-221c-47d9-beec-1062e0dd4aa7"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "35b8a83c-ef5a-4306-832c-66fbeafd2d4a", "name": "tr(r:p1rdt9396-p1rdt9396lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a597011-5e60-46fe-90d6-85728ff0ffa3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc7e0a25-d6d6-4b07-b3dc-4fe5646915e2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc7e0a25-d6d6-4b07-b3dc-4fe5646915e2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d3d8a817-bbdd-4e5c-a3e4-0432297353b5", "name": "tr(r:p1rdt9413-p1rdt9413lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f750e531-5ade-40a9-9bb0-042220ce9807"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8180ee90-a46e-4d85-9742-d47b24f5e169"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8180ee90-a46e-4d85-9742-d47b24f5e169"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f57739f9-f91a-47bd-ab2b-41bc22a489c3", "name": "tr(r:p1rdt9463-p1rdt9463lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "271ab023-4425-40d8-8080-2481c71309b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a015abb-ec63-4b31-9314-283b8499646e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a015abb-ec63-4b31-9314-283b8499646e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "85d043cd-32d6-4018-a524-c982b2241a28", "name": "tr(r:p1rdt9468-p1rdt9468lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b5695dd-714e-4de1-a63a-f142ff0460e1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4dbe1628-cd17-4f37-af2b-dd752c290fa4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4dbe1628-cd17-4f37-af2b-dd752c290fa4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "631e9419-1b56-46f4-baa0-837e133891b1", "name": "tr(r:p1rdt9469-p1rdt9469lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3fd32c7-2866-4699-93a8-dd3a9997d349"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09613257-d4cb-4c50-b35a-8aefc637c0c9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09613257-d4cb-4c50-b35a-8aefc637c0c9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "de8ccb6c-d747-4480-b079-fd149cfb48d4", "name": "tr(r:p1rdt9470-p1rdt9470lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acf91e46-ba32-44c3-a829-14c80a693d7d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1ab8727-2758-4513-8a7d-e02381faf1e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1ab8727-2758-4513-8a7d-e02381faf1e4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "abf8851d-3ebe-42f7-aaba-d53fec8ddcfb", "name": "tr(r:p1rdt9473-p1rdt9473lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4d8bafa-711d-4fd7-8374-7eeaeb43edcd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c14c3211-a0d5-464f-820c-cab04764d907"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c14c3211-a0d5-464f-820c-cab04764d907"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4a2ad2ab-089f-4dac-a5a0-897f492a374c", "name": "tr(r:p1rdt9479-p1rdt9479lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b006c3-79f8-4a27-b76a-d1b458ff2a21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6a8f268-6a5a-4b23-bd91-53c6b031442a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6a8f268-6a5a-4b23-bd91-53c6b031442a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1a93d30f-d1a4-4015-8c87-b38dda765cb8", "name": "tr(r:p1rdt16638-p1rdt16638lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c0d417e-c787-4b0a-a39e-b19ef274b36b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac361065-6b3c-4ac6-96d5-9b474eb3b80f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac361065-6b3c-4ac6-96d5-9b474eb3b80f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "25afcea6-d24a-41da-92e4-6285c2cd8d94", "name": "tr(r:p1rdt16725-p1rdt16725lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2d0eb0b-bbb6-4b3e-bdc6-4c8a0e7d466f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bae9a352-584d-4cf0-9ebd-eb280b684e78"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bae9a352-584d-4cf0-9ebd-eb280b684e78"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f5a6c76a-0ecf-4a13-89aa-362ecadefd29", "name": "tr(r:p1rdt28-p1rdt28lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e71eb2d5-cd10-498d-b9eb-ae337b2f8af6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b3c997d-cd47-439c-aeb9-326e12c2b869"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b3c997d-cd47-439c-aeb9-326e12c2b869"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "86f8773c-114a-4b4c-b9e3-f2717953ca11", "name": "tr(r:p1rdt29-p1rdt29lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b238dc5-7d8e-4b2d-8449-4dc212d7d227"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61fc3980-6aa4-415c-91c1-10d32c7c359c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61fc3980-6aa4-415c-91c1-10d32c7c359c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c02272a2-6a29-4dc3-bc03-1478a851798d", "name": "tr(r:p1rdt30-p1rdt30lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fa95a19-0e0a-49b3-bb86-7103fbaa4110"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d2be3b5-dbfc-4099-af9a-96368e60fe23"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d2be3b5-dbfc-4099-af9a-96368e60fe23"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "3426e057-9462-4775-84b0-7991d0317028", "name": "tr(r:p1rdt31-p1rdt31lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7c543753-fa26-41df-b7a6-3664395c0d45"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3510eedd-535c-4e58-b81e-c5ec09030479"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3510eedd-535c-4e58-b81e-c5ec09030479"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "06dad8ed-fa0c-4bfc-835f-beac3577743f", "name": "tr(r:p1rdt32-p1rdt32lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "834e959c-8ee6-4fff-b1fc-54c20fc0f20b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e374d6d6-1e75-4808-b65a-c7033e1bd528"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e374d6d6-1e75-4808-b65a-c7033e1bd528"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4d7dca1d-26ad-41f4-ae1b-09c3150c2ff2", "name": "tr(r:p1rdt33-p1rdt33lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f55e4012-a11d-4883-baac-9c013aff6058"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "065c8583-45e5-466c-b4c0-1c66bf970abe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "065c8583-45e5-466c-b4c0-1c66bf970abe"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "07af1c2e-7068-4f93-89df-8790c6dfe1c5", "name": "tr(r:p1rdt34-p1rdt34lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a9c4411-f402-464c-ad25-d439b87ef768"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "553a6868-acec-4492-a52d-5aa08414c612"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "553a6868-acec-4492-a52d-5aa08414c612"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "045e1e63-2c81-46df-aaf1-4d47299340da", "name": "tr(r:p1rdt35-p1rdt35lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "edc22f66-e919-448e-b990-76033c281d43"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f98cc066-fca3-4489-9770-047caee3e742"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f98cc066-fca3-4489-9770-047caee3e742"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "686d21ca-2738-4df6-85e2-c888af76c985", "name": "tr(r:p1rdt36-p1rdt36lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8dcdfef-b40e-4f1c-9b7c-e84846f68c5a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a4fb658-c3ba-428a-82bf-b38ae68dd908"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a4fb658-c3ba-428a-82bf-b38ae68dd908"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c5b237cb-07a9-4965-9cd9-3e14350dcdea", "name": "tr(r:p1rdt37-p1rdt37lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dcbfdc3-b597-4e9e-a86f-4d0ff396ba70"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90a16370-67f7-4abd-992c-990d1eb8f17e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90a16370-67f7-4abd-992c-990d1eb8f17e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "da3f8abb-ffb8-4aea-ab9c-4af9437c8824", "name": "tr(r:p1rdt38-p1rdt38lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b45513a3-8e88-45e9-99d3-6d244c90c256"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "752aca33-7682-4e8c-a8b1-624467e02958"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "752aca33-7682-4e8c-a8b1-624467e02958"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f893bdea-9004-4473-94ab-1c3988f9d1b5", "name": "tr(r:p1rdt39-p1rdt39lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a01c83d1-4adb-4b2a-8de3-441d7c1dd054"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "623ec6b4-cb70-4437-9d79-5ec577bc3199"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "623ec6b4-cb70-4437-9d79-5ec577bc3199"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a4e4a009-9d22-4aa9-9fcc-1b5aa8981612", "name": "tr(r:p1rdt40-p1rdt40lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "577124ac-ea2b-4a60-be47-14b0f5db305e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d08444c-79a3-4ba0-8c69-1855a600dea0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d08444c-79a3-4ba0-8c69-1855a600dea0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1fc2c7da-303e-48e2-b221-3ef3ba1d67ec", "name": "tr(r:p1rdt41-p1rdt41lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5b5b3ae-f657-4fd4-a311-ab1dbe9d749e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "793d0bf4-4d9f-4df4-bc95-d528dd7d31d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "793d0bf4-4d9f-4df4-bc95-d528dd7d31d5"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "80968e2c-9233-46d1-bc47-325532bf9287", "name": "tr(r:p1rdt42-p1rdt42lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a778171c-22a1-4320-9e3c-43888d734e34"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8fb27dc9-b404-49d1-84dd-0cde418b037d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8fb27dc9-b404-49d1-84dd-0cde418b037d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "68f7ceff-6b60-422e-bd73-d4d1a0f6e584", "name": "tr(r:p1rdt43-p1rdt43lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7728581d-66fc-4e7e-b2b0-85fa02c90523"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "274aa0ec-f229-454c-b52d-23130bacb97e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "274aa0ec-f229-454c-b52d-23130bacb97e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "8a76055a-3d2f-4462-98c5-e1f8ff4d0cb5", "name": "tr(r:p1rdt44-p1rdt44lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d9ee2ff-e2bc-4d76-b173-5ba5cc48c9b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c813f8a2-226b-431d-a41a-195cf5e8b01a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c813f8a2-226b-431d-a41a-195cf5e8b01a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "16131cf6-271d-4626-98a8-fbae6ee38baf", "name": "tr(r:p1rdt45-p1rdt45lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29a79372-9c75-4a9c-81df-a7491b87e58a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e276abc-bb27-47e4-9de8-adaccbf964dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e276abc-bb27-47e4-9de8-adaccbf964dd"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "76a4d98e-68c5-49bf-910b-f3f35032d52f", "name": "tr(r:p1rdt46-p1rdt46lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05082892-d69e-4c8f-ba19-c2a627e1c345"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aacdcb46-43e3-4147-ac25-3a9c1223e13a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aacdcb46-43e3-4147-ac25-3a9c1223e13a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f0cbaba9-64ec-4d25-8744-ef1281846908", "name": "tr(r:p1rdt47-p1rdt47lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ea0531d-530c-4088-86a1-3de96a8938ea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f031530a-b3fc-4f8e-b0ac-139009d1256c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f031530a-b3fc-4f8e-b0ac-139009d1256c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b0be705e-8c18-4891-b919-bb25a7238d83", "name": "tr(r:p1rdt48-p1rdt48lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1667a8c6-aeb4-4f22-97b8-62ffefcc12a4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f1790fe-a399-46e3-b9e3-5979837777ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f1790fe-a399-46e3-b9e3-5979837777ce"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b0e0d3ff-8ba6-472a-a5eb-d28c6ce44f6c", "name": "tr(r:p1rdt49-p1rdt49lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "137c345c-77cc-4324-bc0e-e0ba896a5f43"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e5bcc7e-f35c-4bbf-a7ff-a82817488b11"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e5bcc7e-f35c-4bbf-a7ff-a82817488b11"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "26b88ccb-02b0-4122-b422-897c4c26a389", "name": "tr(r:p1rdt50-p1rdt50lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c5d8237-0351-4eb2-83e6-13975b37bfa7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8208c617-caa9-46a5-b28a-8a5b0d9898a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8208c617-caa9-46a5-b28a-8a5b0d9898a2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "cc35b6a6-16d4-488e-97ec-7b14db0fa4c0", "name": "tr(r:p1rdt51-p1rdt51lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f5cef5c-bcaf-4cd9-afbb-a18bd14dfcd4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09d7f030-a9b4-4705-82af-6cf140ba64d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09d7f030-a9b4-4705-82af-6cf140ba64d1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "0e0c6d92-cc6e-448f-a29c-1e3178238ad3", "name": "tr(r:p1rdt52-p1rdt52lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6fb1323-f697-4423-a70d-838056200402"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c70a7331-8c41-4370-b053-3eae432d52ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c70a7331-8c41-4370-b053-3eae432d52ae"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "5050b907-1a62-46d6-82b0-89342148ec87", "name": "tr(r:p1rdt53-p1rdt53lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7305e2b-0a48-4630-8b8e-c3819f1c9cd1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2536a0eb-a35c-40d4-9773-b78379e7481a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2536a0eb-a35c-40d4-9773-b78379e7481a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "28ce3059-1ead-42c2-bdee-4daff71b5662", "name": "tr(r:p1rdt54-p1rdt54lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a898f4c-f522-4e69-be4a-e935e339e011"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57889d14-4aac-4aee-a9e2-677a047e8054"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57889d14-4aac-4aee-a9e2-677a047e8054"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a7a2f704-cd96-459a-b12e-4435494a6582", "name": "tr(r:p1rdt56-p1rdt56lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1d8f5898-7d36-4e40-9980-76d11ef18adb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85ad3bf0-7e82-4e32-8106-faddcf725bdf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85ad3bf0-7e82-4e32-8106-faddcf725bdf"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "0c05cc28-0486-48b9-95ba-0b91bb9b6203", "name": "tr(r:p1rdt58-p1rdt58lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a4ccf80-2611-4089-9353-439809aa7854"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3367c40-9f47-42d9-b627-bc502b170f2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3367c40-9f47-42d9-b627-bc502b170f2a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ffc7aa30-29d5-4db5-aab5-dd84d3d0772b", "name": "tr(r:p1rdt59-p1rdt59lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ea7e0bb-bdc5-429a-8889-2f12c94db72e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8aca9934-9439-4ce6-9ee3-475980324054"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8aca9934-9439-4ce6-9ee3-475980324054"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1696924f-e157-42db-86ef-900c1b1cf8bb", "name": "tr(r:p1rdt60-p1rdt60lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d99e903-3536-4a73-b0d5-ca11f5af6e32"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2517cea-05d3-4b7f-b9fc-0df0fde81235"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2517cea-05d3-4b7f-b9fc-0df0fde81235"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "89ed6c2c-a1ba-4a20-8835-2c08c61547b5", "name": "tr(r:p1rdt61-p1rdt61lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "744725a8-af2a-47cf-948f-9d453a932e32"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70f11a44-826f-45b8-9dc3-0f51ce6c9733"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70f11a44-826f-45b8-9dc3-0f51ce6c9733"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "08edc741-554e-4ef1-bd93-218dc727e5ef", "name": "tr(r:p1rdt63-p1rdt63lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab2b6727-4d87-4b00-bd49-ba7a6b1b9ce6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fac6d4e1-b14d-4973-9626-6a4bde2d2a42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fac6d4e1-b14d-4973-9626-6a4bde2d2a42"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "5ad5756b-21d2-45ca-a385-c7e2b2f1bb99", "name": "tr(r:p1rdt65-p1rdt65lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9397c58-45a1-4ec3-bd84-b4cd5b52dc80"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ae9cb89-7cb8-48c6-a5bc-4178ee364ae8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ae9cb89-7cb8-48c6-a5bc-4178ee364ae8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "72eed041-134e-4a31-a0d0-02a861b323f4", "name": "tr(r:p1rdt66-p1rdt66lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99615f32-0614-4c23-a1e1-b3e8e5688cce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfb9fa3b-c758-4c2e-bc51-f297b1ed21bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfb9fa3b-c758-4c2e-bc51-f297b1ed21bf"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f8d59a4d-dfb6-49b3-83c6-0454d6bfd414", "name": "tr(r:p1rdt68-p1rdt68lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb9e5f0f-8bcf-4019-a786-3f24334e9ae7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd2d6296-a302-4027-9e5f-c24a56a1a1ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd2d6296-a302-4027-9e5f-c24a56a1a1ac"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "5e8def15-b1ef-4d36-afe9-0db73af1d8f4", "name": "tr(r:p1rdt69-p1rdt69lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9396562e-4f87-4e04-b248-502b851fe19e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7057debb-bd4d-4156-a253-0f3a14cdd784"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7057debb-bd4d-4156-a253-0f3a14cdd784"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "00e0932e-3680-4ecb-a35f-b8f379416748", "name": "tr(r:p1rdt70-p1rdt70lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50f3b5f3-3fb5-4fb9-b2e6-b37200af0901"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02440066-bc62-4629-96c5-4b497827de5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02440066-bc62-4629-96c5-4b497827de5b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "aec13c01-30e8-4332-b54a-8dac2e56eb19", "name": "tr(r:p1rdt71-p1rdt71lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bcea1fd6-3c51-48af-8528-d3d7bc8e4f01"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e71f106d-4b41-405f-bce9-3d06b336a554"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e71f106d-4b41-405f-bce9-3d06b336a554"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1f2db932-2776-43d2-b812-944ba379f05d", "name": "tr(r:p1rdt72-p1rdt72lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2faff95d-f394-427a-9d62-75224f830c9e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b59eeab-d997-4186-ab59-0424644d5aeb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b59eeab-d997-4186-ab59-0424644d5aeb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a54d9c9c-facb-438a-9923-8a3535cb078c", "name": "tr(r:p1rdt73-p1rdt73lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc531967-1a7b-4424-83ee-e1131c6fd94c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f027d15-df82-4989-93e5-a3b40c862b08"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f027d15-df82-4989-93e5-a3b40c862b08"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "e5380797-1d80-4e0a-945e-4762a3c8c342", "name": "tr(r:p1rdt74-p1rdt74lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b884fef-8b8f-4ed5-9033-b8177d1c7d70"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37880102-8a9c-4f7b-930a-b29a94241866"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37880102-8a9c-4f7b-930a-b29a94241866"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ea369155-ad0d-4a7c-a74b-c12c8e2ecdea", "name": "tr(r:p1rdt75-p1rdt75lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "510ea93c-7dd1-4fa3-ba3f-6c362856c7c1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "699bbf24-59ba-4dba-8bd4-1cf04a7e6e47"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "699bbf24-59ba-4dba-8bd4-1cf04a7e6e47"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "147887b1-2e3e-4a7e-b06c-a473fb5f6bab", "name": "tr(r:p1rdt76-p1rdt76lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfbb212a-9882-4468-86ac-578c93fde1d8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ecf2223-f120-45b4-8aab-a36d60161aec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ecf2223-f120-45b4-8aab-a36d60161aec"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "86c622f6-2403-4cab-95f8-aff9389bf18a", "name": "tr(r:p1rdt77-p1rdt77lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31b06630-2aae-4fe7-9e31-f911c91121cd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3fd9bf7-ecdd-4dcb-966a-f426d5f2ee81"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3fd9bf7-ecdd-4dcb-966a-f426d5f2ee81"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4a5f4547-b555-41df-9f08-d6c0903360f2", "name": "tr(r:p1rdt78-p1rdt78lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36bfd1f1-80ca-4b7d-a68b-9aa77ceff96e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f0255b7-5369-40eb-8814-959b0d4245b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f0255b7-5369-40eb-8814-959b0d4245b6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ecc7b1e7-8a00-4c32-93e5-f1f981ed361a", "name": "tr(r:p1rdt79-p1rdt79lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b32c9763-ddff-435b-a28c-8f65111c6cb2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "624d03d5-ac53-4d58-ac86-62834fa13c61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "624d03d5-ac53-4d58-ac86-62834fa13c61"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "da68cb40-2f31-4750-a2b6-b091f4654833", "name": "tr(r:p1rdt80-p1rdt80lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b03f8e29-a5b2-4bed-b68c-219276674b6a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ce05c72-facf-447f-ba14-cc2ef64579a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ce05c72-facf-447f-ba14-cc2ef64579a8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "87aeed9d-f5cd-4e6f-810f-c6099cb337fb", "name": "tr(r:p1rdt81-p1rdt81lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "063e25be-2abb-49ae-b459-ddd08ba93bb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b610625-09e3-4b72-a8fe-b0c36f5e137c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b610625-09e3-4b72-a8fe-b0c36f5e137c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "83fcf4f2-0d36-4f7a-b36f-b4151a82bc3c", "name": "tr(r:p1rdt82-p1rdt82lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7627cbc6-c54a-432b-8cba-59e448f6d45a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9872669f-fd85-458a-8951-ec12965fb42b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9872669f-fd85-458a-8951-ec12965fb42b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a617b3b6-59a8-4e36-a4ea-11874a9cd427", "name": "tr(r:p1rdt83-p1rdt83lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aa0b7c2-9d55-4faf-8778-76a6f23bcf3e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8dac1e07-5eb6-4945-a3d9-95b77310358d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8dac1e07-5eb6-4945-a3d9-95b77310358d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d41dfd2f-d99a-4bd0-910f-036f4aebe455", "name": "tr(r:p1rdt84-p1rdt84lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e9f4b13-5fb5-46b2-9258-83582d47d61a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdb8aaf1-0e21-42e0-a72d-666646561235"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdb8aaf1-0e21-42e0-a72d-666646561235"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "26f6d003-75a7-4f8c-b229-262ff28235a3", "name": "tr(r:p1rdt85-p1rdt85lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fc415bc-f457-4e9f-bbd4-783a71b67ad6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40f4034e-c735-419b-80cd-d729d75f4692"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40f4034e-c735-419b-80cd-d729d75f4692"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "110f66e7-2818-450b-a67e-5acde54125dc", "name": "tr(r:p1rdt89-p1rdt89lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac4ad276-90cb-48c0-bfd0-1f2aa0233ce2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "468963dd-428d-4810-a28c-1904bc06fa64", "name": "tr(r:p1rdt150-p1rdt150lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12451cbc-eb14-4814-b274-12eb2241c78a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d156fdde-5620-4a6f-b8c1-a3ab986fcc88"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d156fdde-5620-4a6f-b8c1-a3ab986fcc88"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "4ffdedbd-6f86-4c39-ba6a-51dbb16741b8", "name": "tr(r:p1rdt177-p1rdt177lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ad84ef4-4dcc-42f7-99ed-b8d21cebc465"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d64d858-a9f7-430f-890e-a456f8913c30"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d64d858-a9f7-430f-890e-a456f8913c30"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6d4ef4b9-6445-45ff-9620-36a122a1de83", "name": "tr(r:p1rdt178-p1rdt178lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6912a245-ac1c-4ddd-b021-3bc35cbbe2c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3314fa8-a838-4028-abb5-043425fd0785"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3314fa8-a838-4028-abb5-043425fd0785"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "38f32bd3-69bf-4ea6-b2fd-ec94b21cce20", "name": "tr(r:p1rdt180-p1rdt180lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5258d4de-be4c-478d-b752-7f4efb0af0a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3e633bc-311e-4698-a413-9c6cf09c42a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3e633bc-311e-4698-a413-9c6cf09c42a8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "16bc9340-852f-45b4-8c50-5aafae060aaf", "name": "tr(r:p1rdt181-p1rdt181lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79d0fee6-369b-4f95-a2d2-cd05232652e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05401825-91f8-41f8-9204-ab5806458594"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05401825-91f8-41f8-9204-ab5806458594"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "fd2bbd2d-e55a-4574-9301-aa415ede0134", "name": "tr(r:p1rdt182-p1rdt182lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08e378d4-4ca6-4c9e-93fa-36ff87a3cf0f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db407ddd-fb81-4767-99e1-9aeab12fc770"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db407ddd-fb81-4767-99e1-9aeab12fc770"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "8cfbd069-d0c7-45ae-a317-62a2b705c48e", "name": "tr(r:p1rdt209-p1rdt209lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcb27aab-e828-41a6-ad98-d197897a1a69"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4724ea16-dc31-48f8-98b8-b9a223e9a4bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4724ea16-dc31-48f8-98b8-b9a223e9a4bb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "12ffe536-6060-4f3e-907b-af4d833feb8b", "name": "tr(r:p1rdt210-p1rdt210lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d782d5e-3960-415c-9e33-6742777a5a0a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05f6a3bf-d465-4f16-8205-616d1f4dd465"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05f6a3bf-d465-4f16-8205-616d1f4dd465"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "938e5105-62c4-4dab-b455-5ac4f54fcb4d", "name": "tr(r:p1rdt211-p1rdt211lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9401940-26a4-40f3-9b9a-5231a5c4e171"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1d5af6ce-9a4c-414a-bbd8-15d82f50cb57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1d5af6ce-9a4c-414a-bbd8-15d82f50cb57"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "91a80b45-db0d-4e91-b5a9-5fb6548e00dc", "name": "tr(r:p1rdt233-p1rdt233lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f5ed5d5-93fc-4f3c-a78b-df7019863b67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "591461d4-20da-4165-a210-4dbaedd81016"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "591461d4-20da-4165-a210-4dbaedd81016"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "228841e9-58e9-49e3-804f-445cc0619ab5", "name": "tr(r:p1rdt234-p1rdt234lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80331f15-8b31-454c-a289-49cb79923252"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e480f304-b192-4107-91e1-131d481657b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e480f304-b192-4107-91e1-131d481657b2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "40659e90-bb60-4c4f-a678-ce45935e490f", "name": "tr(r:p1rdt235-p1rdt235lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14b85850-d83e-4a5e-83c3-ccb485bb85aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d8a6708a-d098-4e02-aac6-4aba7fdc71a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d8a6708a-d098-4e02-aac6-4aba7fdc71a5"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a5c0e877-4159-4080-9098-05bf7f634c74", "name": "tr(r:p1rdt236-p1rdt236lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "190d6c51-94b6-462e-8fee-cce57f1ab66d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7dd709e3-c5ec-4a01-8297-11f4d1261c3a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7dd709e3-c5ec-4a01-8297-11f4d1261c3a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "7769b43e-a233-4400-b584-7a9f35d5a83e", "name": "tr(r:p1rdt237-p1rdt237lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8c8b8f8-7a41-4d16-b509-2d7c7af9509d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b72726f3-250c-4d98-86bc-5120137bd0f1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b72726f3-250c-4d98-86bc-5120137bd0f1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "7d4d8011-cd32-41e0-bdbf-c7f5d31224e2", "name": "tr(r:p1rdt251-p1rdt251lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b801037a-e1bb-4c5c-8d18-ed285c8c1d3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42dff28c-89e7-4b56-bf23-3dcdd3ca216f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42dff28c-89e7-4b56-bf23-3dcdd3ca216f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "0f9e6d0b-d35a-481b-b931-182fab18aed5", "name": "tr(r:p1rdt252-p1rdt252lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69b2ee46-ab5f-48c8-a26b-170ed2b57fcb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5fd6466-e740-4f06-a842-798195d62154"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "72716a86-0835-4f9b-8e47-9a6051a19336", "name": "tr(r:p1rdt253-p1rdt253lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1a85646-be2b-4b15-9c2f-cc603c7e06df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "704fece3-3b83-4c0b-bcd1-d463b3cdaf6b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "704fece3-3b83-4c0b-bcd1-d463b3cdaf6b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d1c72dc1-3fc7-4da6-9a5d-72909f222914", "name": "tr(r:p1rdt254-p1rdt254lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ab802e3-3a0a-413c-8865-e3b3d08e44a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "655d8f44-aa2f-4548-a1ca-83fcce9fa7aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "655d8f44-aa2f-4548-a1ca-83fcce9fa7aa"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "bf18b63e-79ca-428f-a8b3-d5a935d41cbd", "name": "tr(r:p1rdt257-p1rdt257lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fb307f7-3690-4931-999a-4daab4d8c9e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4c28500-44f7-47c6-b8a8-d1e3468494e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4c28500-44f7-47c6-b8a8-d1e3468494e3"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "96da8edc-0a10-48ed-bb7d-3658fda97e9f", "name": "tr(r:p1rdt258-p1rdt258lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e28087b-b80e-4043-b0f0-0bc82c91f5e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad9ffaef-f21b-43da-9f67-3a8271edb6bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad9ffaef-f21b-43da-9f67-3a8271edb6bd"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c3a4c349-43bd-4f33-98fa-ccf7e44ca6f5", "name": "tr(r:p1rdt259-p1rdt259lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33a0a070-9cce-4a82-bd22-24a65f02ef97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6a0feb3-78c1-4d69-8d18-2a8c3abdcf54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6a0feb3-78c1-4d69-8d18-2a8c3abdcf54"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ecbce8a2-3f89-4fa2-a55a-3bd07a3ac13f", "name": "tr(r:p1rdt260-p1rdt260lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba0ef4a3-43ba-469b-8ce8-ca7a5a984071"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d8d796d8-6750-4ca5-ae07-1b07331ce6ee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d8d796d8-6750-4ca5-ae07-1b07331ce6ee"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6d2548c2-862a-4a2f-b2c3-1d8870d42a76", "name": "tr(r:p1rdt261-p1rdt261lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "209cebda-044a-42a3-b2f0-fe5b76b80643"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fe4ec5b6-61fb-4b66-9e43-19d81af88966"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fe4ec5b6-61fb-4b66-9e43-19d81af88966"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4bd983f3-706d-4920-a462-e4bf12558318", "name": "tr(r:p1rdt262-p1rdt262lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf660777-f77e-4d9b-afff-73a84274c270"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30952601-1479-4770-9b77-9fe3465310b7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30952601-1479-4770-9b77-9fe3465310b7"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "034163b4-1e88-4baa-a811-5fbd58057562", "name": "tr(r:p1rdt263-p1rdt263lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e26e5dc-8c98-4fcd-b125-3265eb00f3f2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c7501f4-0394-4766-a3c5-b17fda7f3817"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c7501f4-0394-4766-a3c5-b17fda7f3817"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "559841a4-f8e4-4cdd-b1c6-04b11c6d09dc", "name": "tr(r:p1rdt270-p1rdt270lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7eca59ac-01f1-40d7-a0ec-51f355285e01"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d33a03d6-fddc-4e47-8018-cd7d290b30b0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d33a03d6-fddc-4e47-8018-cd7d290b30b0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c6c81cef-c3ee-431b-a3ab-6ad7205c02a8", "name": "tr(r:p1rdt275-p1rdt275lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d4e6a87-0313-419f-8feb-7ea3a29f59ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6715c6a-6869-412a-8e59-e5c2eb03c56b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6715c6a-6869-412a-8e59-e5c2eb03c56b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6bb22125-784e-40ef-bbc5-22745e6216db", "name": "tr(r:p1rdt276-p1rdt276lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "186ffdfe-2346-4218-bd6b-b813ea6b3b62"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b478b4f8-8d5e-47b0-a56a-8b991dc8d944"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b478b4f8-8d5e-47b0-a56a-8b991dc8d944"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ae187547-57ce-46fc-9314-8dda6c95cd4f", "name": "tr(r:p1rdt277-p1rdt277lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "add5e39f-f02e-4a61-a156-d5721cec25d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24486e15-ff1e-45b3-aa02-703263f04844"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24486e15-ff1e-45b3-aa02-703263f04844"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4676c5fd-19ba-4329-a862-9e9801bd00a8", "name": "tr(r:p1rdt278-p1rdt278lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b89bfea1-97cd-41f7-af59-9602a3fc6c06"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8af5824-d5d7-4cba-98b7-d72993909f22"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8af5824-d5d7-4cba-98b7-d72993909f22"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d0bfd334-fcc6-47b4-bfc1-72eb7bb1598c", "name": "tr(r:p1rdt279-p1rdt279lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "153bb615-5ee5-4eec-bcf7-94ea0098aeb6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bf679fe-712f-4db6-9df9-debb29b7ee73"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bf679fe-712f-4db6-9df9-debb29b7ee73"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "da111543-380a-4eb1-88b8-031590d01eda", "name": "tr(r:p1rdt280-p1rdt280lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9cb7919-b8bd-46c1-a173-90a5d241c46e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e4eafd2-0f68-4e2a-a62c-89cb877004d4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e4eafd2-0f68-4e2a-a62c-89cb877004d4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "655bfadd-98d9-4039-821c-21dbe9549447", "name": "tr(r:p1rdt281-p1rdt281lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac745c6f-6e78-4a68-affa-649f91d3aa7c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e01a56d-1bfc-4169-9c3e-1373f9dbeb38"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e01a56d-1bfc-4169-9c3e-1373f9dbeb38"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "015e49ce-e6a5-4944-aaf3-b61823a75f58", "name": "tr(r:p1rdt297-p1rdt297lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d32493ec-06be-48ef-959e-779c79c507a3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a8430e1-656f-4fe2-a11b-00adf429d75d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a8430e1-656f-4fe2-a11b-00adf429d75d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d68d8140-dff3-41be-a497-53455f71c1f6", "name": "tr(r:p1rdt298-p1rdt298lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a468f13-c61f-4c01-aa27-c75fb02030e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33e93250-9c11-4650-9469-412129855857"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33e93250-9c11-4650-9469-412129855857"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b887118e-e038-4a64-9fa7-6038d52ec663", "name": "tr(r:p1rdt303-p1rdt303lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9672c49b-8316-4907-b204-7505483210b0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6353ab92-f66f-47d8-97ac-058cf030ff82"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6353ab92-f66f-47d8-97ac-058cf030ff82"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "5d8d8e70-8ce0-42db-a87f-175f615651be", "name": "tr(r:p1rdt304-p1rdt304lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c51ccb17-eed6-4ce0-b839-e7b26001fe3e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a22ac71-bf3a-4016-86ce-fb25f471be5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a22ac71-bf3a-4016-86ce-fb25f471be5b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "0f017bf0-d183-4c7b-80ed-7c974ee6f0bd", "name": "tr(r:p1rdt305-p1rdt305lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b936973-54dc-41e7-a413-8932c31f0793"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90948977-fe1a-43b3-a8a4-86c080ae4906"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90948977-fe1a-43b3-a8a4-86c080ae4906"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "d74936db-efae-41d6-84f2-34c53eef6e48", "name": "tr(r:p1rdt306-p1rdt306lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57a78c71-e5a8-4dfd-8359-e368b7b198fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53eba878-66fa-4d30-8af4-1f583abe5f16"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53eba878-66fa-4d30-8af4-1f583abe5f16"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b13ff87f-aca0-42a0-a97e-45cfc6179f01", "name": "tr(r:p1rdt335-p1rdt335lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b07c4a6-39a7-4521-bce7-3f1ca0ff4a66"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8e448ea-e66d-4e16-80c0-8e742d7cac55"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8e448ea-e66d-4e16-80c0-8e742d7cac55"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1b3a45a4-d129-4c3f-8eb1-9066ad24ac9c", "name": "tr(r:p1rdt374-p1rdt374lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d425a00d-c0e9-465d-9d9b-af4d64708fba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35993388-185f-4d1d-9dcb-16eb7556728f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35993388-185f-4d1d-9dcb-16eb7556728f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "0c577442-ca1d-4668-b313-e9fbb1e29ad8", "name": "tr(r:p1rdt376-p1rdt376lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f2a0358-b10d-4b62-8f8d-9a5054fae87d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d354e81e-b007-4bbe-b1db-50d7afacd0e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d354e81e-b007-4bbe-b1db-50d7afacd0e0"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "de6b39ba-8c53-4f20-8506-bd2983c7866c", "name": "tr(r:p1rdt383-p1rdt383lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d49257c8-f8eb-4024-9c02-461d18cdd3d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8569c197-174f-46ef-96c2-e0c674d7b046"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8569c197-174f-46ef-96c2-e0c674d7b046"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b775f5a3-abc7-439d-8cc2-1dfdb80e9ee2", "name": "tr(r:p1rdt384-p1rdt384lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7adf2f4b-f0fd-4c53-abcf-d90fe1a2b4c4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c56b4839-f007-4c9b-93a7-9147399f983f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c56b4839-f007-4c9b-93a7-9147399f983f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "dfb875e0-909c-48e0-a0f3-c240ef90cdec", "name": "tr(r:p1rdt385-p1rdt385lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91f76b91-e00a-4a88-8ee8-ec403c2c7d96"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "579c3e97-d1dc-4306-91e6-4cbbed29f882"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "579c3e97-d1dc-4306-91e6-4cbbed29f882"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "fb2a2471-54f3-48e3-9ee1-13f4e72e499a", "name": "tr(r:p1rdt414-p1rdt414lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3034e62-dd19-4ecb-bb39-6d0566e3a2ef"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29a78735-964b-4381-bea0-01e5b1b79be9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29a78735-964b-4381-bea0-01e5b1b79be9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "860da100-ad3e-4792-8a28-931f8187fdf3", "name": "tr(r:p1rdt415-p1rdt415lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "101c6236-a474-45c8-b065-f5fa045b1107"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "789d55de-619d-43cd-b056-ebe1be4c2dea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "789d55de-619d-43cd-b056-ebe1be4c2dea"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "feeba731-1ea5-4dc1-9a62-c0e1d7795eea", "name": "tr(r:p1rdt416-p1rdt416lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d16d5f5e-a376-4e39-a845-d2cde8800da3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473f5822-3412-4f3d-836e-f62314efa5b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473f5822-3412-4f3d-836e-f62314efa5b2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "47414dae-3422-48b1-bdca-7b83009a888f", "name": "tr(r:p1rdt417-p1rdt417lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "71fa675e-bc20-46f7-b6f1-c88962f9f3cb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98bb09be-6506-49e8-8fd8-1a01d6861162"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98bb09be-6506-49e8-8fd8-1a01d6861162"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b0547079-9b1b-44dc-ab7c-c29dfea00990", "name": "tr(r:p1rdt418-p1rdt418lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16b7f1e9-3405-4c5f-96c7-d5c08d791907"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e189aaf-7650-49b4-83dd-94a29111aca2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e189aaf-7650-49b4-83dd-94a29111aca2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "469de0ef-7a25-4acd-9205-a71329a39894", "name": "tr(r:p1rdt419-p1rdt419lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81cfd2a2-295c-4b73-abba-05ffee810523"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d9603d6-5e5e-4cc0-aa86-1bdb80f7e1cf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d9603d6-5e5e-4cc0-aa86-1bdb80f7e1cf"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "47093818-356c-43f7-a773-06ced59d5483", "name": "tr(r:p1rdt420-p1rdt420lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4cf05060-0a39-49a9-a761-79fb136e2965"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51673983-9230-421b-8501-bf71601b1b13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51673983-9230-421b-8501-bf71601b1b13"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d972da8f-8281-4cb3-ba18-4eb86c2e9897", "name": "tr(r:p1rdt438-p1rdt438lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10620dcc-049c-4417-b4ac-922a56c0d4a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41f19802-32ca-4afc-8418-fe93e3ced1bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41f19802-32ca-4afc-8418-fe93e3ced1bb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1e703d7c-207c-41bd-8432-62623e3294cd", "name": "tr(r:p1rdt445-p1rdt445lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11571d26-573f-49f7-99fd-828dde97afd8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc7e7e51-f849-4bf4-b720-462daeb21932"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc7e7e51-f849-4bf4-b720-462daeb21932"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4ef117e0-3533-4ed5-a707-27b8b79018e0", "name": "tr(r:p1rdt446-p1rdt446lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3dfe357-889d-42e0-a59a-821c9f843456"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0727e1f5-f2ca-4e19-9dc3-89e185002e52"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0727e1f5-f2ca-4e19-9dc3-89e185002e52"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "31791e27-69b5-46d6-8de1-580b87fb30a0", "name": "tr(r:p1rdt452-p1rdt452lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d51e6f65-c45c-4f10-a17f-6ef684a0a06c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44f86829-17fc-4e83-b2a5-705454293161"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44f86829-17fc-4e83-b2a5-705454293161"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "dea578b9-0003-4140-837c-70a58205dfbf", "name": "tr(r:p1rdt453-p1rdt453lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1bb6f93-7aed-47d7-99db-7c17352a42b8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d58e1471-844f-46ef-9d9a-43753b1dee25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d58e1471-844f-46ef-9d9a-43753b1dee25"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "de71a091-0216-4333-98f4-8e2ee12f7aa3", "name": "tr(r:p1rdt454-p1rdt454lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "82459f47-0c6f-4173-8c35-5a9fe5db9713"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b3e7941-9bdd-48f9-a4a5-a553da9bbb57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b3e7941-9bdd-48f9-a4a5-a553da9bbb57"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "7146b2ad-9e2f-4f11-a4a5-d9ea6e8d1f02", "name": "tr(r:p1rdt455-p1rdt455lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "183de04a-a665-4112-a912-1df68b61d164"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53b40b3c-db5a-4fa0-bedb-f293c6eac473"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53b40b3c-db5a-4fa0-bedb-f293c6eac473"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c7fedd72-fdc1-4ce2-9c76-ae0aa80d0095", "name": "tr(r:p1rdt456-p1rdt456lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf205ba7-ac66-4318-aeca-c75eb96cbd1e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6abe982-a205-4607-bacf-08e9d7cb6f54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6abe982-a205-4607-bacf-08e9d7cb6f54"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "780c1284-1c66-4d72-92d1-cf26850a20c2", "name": "tr(r:p1rdt457-p1rdt457lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12fef7fc-57f0-4494-becd-4724b84dbbcb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "866745cc-62c9-429f-8389-fcc5a1710f17"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "866745cc-62c9-429f-8389-fcc5a1710f17"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "226ddf12-0560-4cd0-a652-b078040e8853", "name": "tr(r:p1rdt458-p1rdt458lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b61caefd-d5aa-4019-9ac0-aaf8cedc71d0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67e071ab-e3dc-4779-9e81-585547cd22ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67e071ab-e3dc-4779-9e81-585547cd22ca"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "50a65c14-ae69-47d6-ae06-21a2674632d0", "name": "tr(r:p1rdt459-p1rdt459lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12d5c579-0570-44db-a751-8eeb92355af9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9eb57d99-ae80-43da-b0cb-b26bdd583e1a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9eb57d99-ae80-43da-b0cb-b26bdd583e1a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "93fa4f7d-bc58-4a12-a440-e0c490ea7b13", "name": "tr(r:p1rdt460-p1rdt460lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59b616e5-76b8-406c-843f-5c71398af81b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028bc055-0ee6-4729-8cd2-15bd7153f975"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028bc055-0ee6-4729-8cd2-15bd7153f975"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "1f7a885d-21ca-439d-8116-826789387357", "name": "tr(r:p1rdt461-p1rdt461lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc35f44e-d8d9-41d0-b014-caa3d8d7a91e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd9a4931-435b-4b48-907c-024c0b8a4816"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd9a4931-435b-4b48-907c-024c0b8a4816"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f12f78be-1ac8-4e86-98fe-de6b0683fa21", "name": "tr(r:p1rdt462-p1rdt462lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fcfdc5bf-1c87-42e2-8b35-1f7125d3b5ed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d96f458-607c-4820-90b1-6fb2625ace7f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d96f458-607c-4820-90b1-6fb2625ace7f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "b7ade355-2af9-4a38-a2d7-80f3335d2f0c", "name": "tr(r:p1rdt463-p1rdt463lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7637cfdb-6a14-4313-95d4-e25beba178f3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f660c35e-85f8-4f0e-b03b-806006c76c67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f660c35e-85f8-4f0e-b03b-806006c76c67"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6148cbd4-2f8c-491c-9c54-ff853b4687d9", "name": "tr(r:p1rdt464-p1rdt464lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a634585d-0c70-428e-a3b2-1ec4717d7878"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "749e07aa-74ce-40f2-a352-9c55f9914377"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "749e07aa-74ce-40f2-a352-9c55f9914377"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "70d8c332-07fd-46c0-a5a7-a6324f5ec5bb", "name": "tr(r:p1rdt465-p1rdt465lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a94f7afe-e8b0-4b24-8196-6b05e98c3830"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "433b0872-49c4-452c-941c-8083a72840ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "433b0872-49c4-452c-941c-8083a72840ce"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "780d3254-dfcd-415b-afdf-f9fdb2cce1dd", "name": "tr(r:p1rdt466-p1rdt466lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b20fa59a-8573-461a-9c4a-0d47e40d2601"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f422478c-0d77-48c8-87fb-e883d945f8a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f422478c-0d77-48c8-87fb-e883d945f8a6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "31fd8d26-743e-4351-a4ae-a932c424b517", "name": "tr(r:p1rdt467-p1rdt467lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ae86125-88c3-44fb-9fe9-1a5d820606f6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23ed76af-dcb2-4333-ae4c-d7439a37cf87"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23ed76af-dcb2-4333-ae4c-d7439a37cf87"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4b987818-3fb4-41f5-b55b-d2cfb74befcd", "name": "tr(r:p1rdt468-p1rdt468lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a180b972-cf0e-4a2e-9bcf-a0ad90bb3d83"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b368fb8f-7f4d-4558-b6b2-2e1db4087727"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b368fb8f-7f4d-4558-b6b2-2e1db4087727"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "18968b56-3a29-41e6-8cbd-8e4fe75001da", "name": "tr(r:p1rdt469-p1rdt469lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48179f57-b0b9-491b-b654-81583768923a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d12ab15f-746d-462b-b395-e2b330ba1226"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d12ab15f-746d-462b-b395-e2b330ba1226"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "bac74da6-006a-4067-88ac-cf7b2ae508c5", "name": "tr(r:p1rdt470-p1rdt470lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86178159-ccd7-45a3-b711-ac237321d52a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15ab2647-a801-4cb5-a1f7-528118ff5dea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15ab2647-a801-4cb5-a1f7-528118ff5dea"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "58fdf097-af18-4b81-9503-d9f13735bc26", "name": "tr(r:p1rdt471-p1rdt471lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eed7e6a8-2b4a-4a54-b69a-e3e1a0614213"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40d98c0b-4c66-4581-9553-f5f57c4b27b9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40d98c0b-4c66-4581-9553-f5f57c4b27b9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "346f5458-a006-49fe-9e5e-9c356990a6a0", "name": "tr(r:p1rdt472-p1rdt472lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fa14b51-a977-4e40-8f9c-28249e576fcf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f026a1d3-23b0-4454-a09b-e1c08cc06392"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f026a1d3-23b0-4454-a09b-e1c08cc06392"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b8909095-2209-43a8-8464-b209838a828c", "name": "tr(r:p1rdt473-p1rdt473lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76880999-6f79-4fc6-9367-1c419eee26d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f435ec5-8c03-45ba-925b-83bad9501047"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f435ec5-8c03-45ba-925b-83bad9501047"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "dc6f4797-c71e-4d15-b933-feb4df8752ec", "name": "tr(r:p1rdt474-p1rdt474lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d709af4b-1115-403b-a68d-76c63c93adf2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "839858f4-3b18-40c3-86f3-e27225e6aba4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "839858f4-3b18-40c3-86f3-e27225e6aba4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "7ecefea9-516a-4cb1-8c06-cac3a09bcc5e"}}}}, {"uuid": "a492d8ab-a787-43c8-8be0-cab66a7fe3ed", "name": "tr(r:p1rdt475-p1rdt475lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c39140c6-8892-480a-81b9-738c67ed1591"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1be3e20a-3890-4e9c-b568-ca99421e751c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1be3e20a-3890-4e9c-b568-ca99421e751c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6c7260e3-92c6-44cf-9183-fc804409b3d6", "name": "tr(r:p1rdt476-p1rdt476lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5421facb-0713-404c-97e9-56669fc762b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ffde8c6-9dba-4f13-bda5-a0edf17c736d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ffde8c6-9dba-4f13-bda5-a0edf17c736d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "d82f544d-1e58-46b4-9ecf-d4338fbccc82", "name": "tr(r:p1rdt477-p1rdt477lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d1eb09d-dff4-4fa3-b96f-ef59b63d6128"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7c94703b-303a-4713-95c0-b2933fe0e70b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7c94703b-303a-4713-95c0-b2933fe0e70b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d4ce0825-6ee4-4ec0-b8e1-1563e762a41a", "name": "tr(r:p1rdt478-p1rdt478lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eba354c-f4bf-4c49-a8ad-998ab9489e5a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c93c776d-68b8-4e4e-8e5e-d5e34003473c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c93c776d-68b8-4e4e-8e5e-d5e34003473c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "50c07068-48a1-4f26-a8f9-e98aa62f0fdd", "name": "tr(r:p1rdt479-p1rdt479lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85acd1fb-6da3-432a-9508-855ca991641b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8037b713-d948-43c9-8370-fb8fcf6dec15"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8037b713-d948-43c9-8370-fb8fcf6dec15"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d06c50e8-54b3-4baf-9665-3fab274a9a46", "name": "tr(r:p1rdt480-p1rdt480lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e5c3d02-1cd2-45e4-90d3-10b135c65f13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "423402f9-4160-481b-9951-a955f8314075"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "423402f9-4160-481b-9951-a955f8314075"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "733cc0fd-6a39-4cd5-981f-4aa1b1b62549", "name": "tr(r:p1rdt481-p1rdt481lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cf3136f-6dbe-4ed7-b9cb-e9f73b191f76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1761b021-00e0-4880-9f05-62cf67aef0e6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1761b021-00e0-4880-9f05-62cf67aef0e6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "148864d6-cab0-456d-8328-a75ad9b03ce3", "name": "tr(r:p1rdt482-p1rdt482lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10c2463d-8563-4737-aa7d-e1195c0af9f6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c445ea76-5167-4d55-b0c5-cc53dadc5b5e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c445ea76-5167-4d55-b0c5-cc53dadc5b5e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "16ca4d3d-9bed-4e6b-9ece-eb18548033ae", "name": "tr(r:p1rdt483-p1rdt483lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69b5d686-dae0-44c5-a261-f1a73bcb168e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "475b6a50-9814-4016-bb88-be5b1b2ac31d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "475b6a50-9814-4016-bb88-be5b1b2ac31d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "ab0dffc8-6dfa-406d-b78d-386b299b2e2a", "name": "tr(r:p1rdt484-p1rdt484lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b57b8e2b-62c2-49a0-801d-02cab8092ebd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f396745a-5edb-4ab8-8bc7-2b181719cbf4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f396745a-5edb-4ab8-8bc7-2b181719cbf4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "2bc14fe0-06d7-4d06-b082-4fa14b69d913", "name": "tr(r:p1rdt485-p1rdt485lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "445f61a4-8045-4558-a3c1-bb44336737ec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da38ec0a-f37d-4a5c-8da0-93410a8fb475"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da38ec0a-f37d-4a5c-8da0-93410a8fb475"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "181d142b-a1d2-40c7-919b-2bfaf1cb98b1", "name": "tr(r:p1rdt486-p1rdt486lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd2f4b00-6e8b-4faa-a760-7c28f8d36a36"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5401d366-a5a2-4753-82b7-ce4fa08a1227"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5401d366-a5a2-4753-82b7-ce4fa08a1227"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "e13b87a6-1453-493b-90f8-63417bffadc3", "name": "tr(r:p1rdt487-p1rdt487lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfb0d992-ab18-4f73-933e-a01ce73ef3b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47fbd02f-6c12-4bd6-9d6d-2e0cddbfcd88"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47fbd02f-6c12-4bd6-9d6d-2e0cddbfcd88"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "bea3ce73-1bb4-443c-82bc-d9633e9913c4", "name": "tr(r:p1rdt488-p1rdt488lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fa474a3-1d6b-454b-9170-6a8d13789c43"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e517b810-e6b9-4c89-b47d-1921fcf88edc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e517b810-e6b9-4c89-b47d-1921fcf88edc"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d221e7c0-5e3a-459f-9f2a-d00e62491d88", "name": "tr(r:p1rdt489-p1rdt489lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cee642e7-12f0-4746-841e-d8cda6fff57e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25637062-8ca3-4694-a27b-7be93e89fe1f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25637062-8ca3-4694-a27b-7be93e89fe1f"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "948d2dba-9df5-4bb4-af04-fb9494f3d65b", "name": "tr(r:p1rdt3776-p1rdt3776lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "170a2bcb-d7ce-4617-855b-9111b84262ed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ae14df0-ab3b-47ba-9f83-c09f03999c76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ae14df0-ab3b-47ba-9f83-c09f03999c76"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "bea0945a-b96b-4d1e-af74-0291cbd1a874", "name": "tr(r:p1rdt3777-p1rdt3777lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f9af980-79c4-4daf-b8fc-44e02953f98b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4662f3f5-e75b-4b75-a6d6-7ada745d5cca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4662f3f5-e75b-4b75-a6d6-7ada745d5cca"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1c340bc5-1d86-44e6-860a-aa40bf29d777", "name": "tr(r:p1rdt5098-p1rdt5098lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9100fbd6-863e-48b2-94ed-aca1ef0947bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e734d7a2-9161-41c0-ba78-9f9f87120acd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e734d7a2-9161-41c0-ba78-9f9f87120acd"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "7f4eefd7-8cd4-4fbc-b0c6-c16c3485fc58", "name": "tr(r:p1rdt5548-p1rdt5548lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bf1b63d-fbce-42f8-9948-2e09bfa67409"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91754be7-2a91-4a0e-9856-43d08ecc7c70"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91754be7-2a91-4a0e-9856-43d08ecc7c70"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "9ccccbb6-1805-4071-91ed-04ab43c1c51c", "name": "tr(r:p1rdt5551-p1rdt5551lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f7fed4f-197e-4a79-97e5-df595377736b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9dec144-ef2e-44fe-990a-c9d70b740410"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "c1bbd3f0-4b5f-4f5e-9f82-e2b15dd3929a", "name": "tr(r:p1rdt5557-p1rdt5557lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cca8918c-30e6-4619-a5e0-8c0d3451f9c4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05b867e6-2f18-49e7-9869-55bd5048c201"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05b867e6-2f18-49e7-9869-55bd5048c201"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "28066d5a-8a37-45e6-9713-935dbb6c1a49", "name": "tr(r:p1rdt5560-p1rdt5560lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68117bef-16c5-40c9-9356-76ef5c056650"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5838960-8556-4e4a-95e9-8ba9ffc85141"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5838960-8556-4e4a-95e9-8ba9ffc85141"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "16844ce2-d0e7-4577-8d19-df2522470625", "name": "tr(r:p1rdt5561-p1rdt5561lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "756f6cd8-301b-4fac-b414-d72853616c6e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "133a0221-0cd5-46d2-af84-e80e7951c96d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "133a0221-0cd5-46d2-af84-e80e7951c96d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "eab10644-9384-4c94-aa36-fb0daba50b19", "name": "tr(r:p1rdt5563-p1rdt5563lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad24f98d-f022-4e62-b80b-426052810759"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a150dd3-61a4-4df9-90e2-6c72f80af819"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "9a8345b1-a786-435c-b6a2-aa53580a9679", "name": "tr(r:p1rdt5564-p1rdt5564lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8444c9ea-ff7a-4b0a-9ea6-9c18770565cb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8deb73b9-51fc-447d-9da7-14a6dccff646"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8deb73b9-51fc-447d-9da7-14a6dccff646"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "3e20fcc3-e522-405e-b12e-8621cb7b680c", "name": "tr(r:p1rdt5565-p1rdt5565lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5e479d3-aae0-47b8-b707-bad1191df1e7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60dc1291-a843-4abf-bfc6-ff8afc8c0b98"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "ec61176f-dfbb-4efa-9041-5ed2ff4bf1e3", "name": "tr(r:p1rdt5566-p1rdt5566lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fed9557-b170-4817-8bd8-efc3b9f7c982"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95a5450a-6630-41b8-863f-0c1f3fcfa7ab"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95a5450a-6630-41b8-863f-0c1f3fcfa7ab"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "947b40bb-4805-40ad-a01b-6cf8e7426679", "name": "tr(r:p1rdt5568-p1rdt5568lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c83b6ee-20fc-4ca0-a778-44735283afd5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "613d178b-a566-408d-bad0-e4a170eea971"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "613d178b-a566-408d-bad0-e4a170eea971"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "64da0817-f4a8-4b5f-821e-148131beb92e", "name": "tr(r:p1rdt5574-p1rdt5574lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9906676-e9b9-4d51-b1c2-a6b6fe187faa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "248e065d-80ed-4926-9625-295c83da6b61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "248e065d-80ed-4926-9625-295c83da6b61"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "999c9328-68fe-4d34-86d9-ce9c7fb60c2f", "name": "tr(r:p1rdt5577-p1rdt5577lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1c8b424-4509-4fd2-93e2-4fd54f6cf49a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21ef4ae6-b80e-49f1-8d00-1cb6e27bc8f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21ef4ae6-b80e-49f1-8d00-1cb6e27bc8f9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "777a7223-aa6f-4f59-8319-64339d066aab"}}}}, {"uuid": "e453767e-243b-4848-8e6f-d4589c09194a", "name": "tr(r:p1rdt6261-p1rdt6261lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53e5fee4-5a31-448e-8bd0-d8996468d085"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9859b30-0238-493e-be1a-cb6717413ba9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9859b30-0238-493e-be1a-cb6717413ba9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d1f70d0a-2390-439b-9b24-5f2fd1ba1b0e", "name": "tr(r:p1rdt6262-p1rdt6262lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf092ec9-ecda-4216-9ac0-0bc035973515"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2172b57-622b-44c1-8388-f1e2b1def312"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2172b57-622b-44c1-8388-f1e2b1def312"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4c14ecdf-6121-49db-8273-ea7012401a9f", "name": "tr(r:p1rdt6263-p1rdt6263lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c61df077-693e-4e67-aea6-ee60b99406d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4717b000-fd39-4647-9fbd-5152323dacee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4717b000-fd39-4647-9fbd-5152323dacee"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f6f3fa51-a1a9-40ca-a3b6-7a6ccdb26701", "name": "tr(r:p1rdt6264-p1rdt6264lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a03d20d-664a-4e80-abec-a36910787829"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e916c16-525d-4092-b627-ad44b4bf4ee8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e916c16-525d-4092-b627-ad44b4bf4ee8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "836aa093-a7b6-4940-8c75-2a7058b9fd71", "name": "tr(r:p1rdt6265-p1rdt6265lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d316c13-77c1-4412-baf9-801f7e5ae407"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6bb5544-e583-4ded-9a10-23be70f5598e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6bb5544-e583-4ded-9a10-23be70f5598e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a7f86fff-0adf-4b9e-a9b6-97e3117ec95b", "name": "tr(r:p1rdt6266-p1rdt6266lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e22d08f0-2afc-426a-a0c0-6b00cc1103aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8af5f9d5-965c-4a0c-a811-67d3bed744ee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8af5f9d5-965c-4a0c-a811-67d3bed744ee"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "30021e75-15ad-4990-ba5f-192e884daaac", "name": "tr(r:p1rdt6267-p1rdt6267lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a1d9cfa7-0024-4896-a263-2715086f2ad6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0ddd898-3193-4bff-80f4-fd4a7eae9aec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0ddd898-3193-4bff-80f4-fd4a7eae9aec"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "5db55ec0-9b26-43e1-82d6-1c6f792b80a2", "name": "tr(r:p1rdt6488-p1rdt6488lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63b2f1e6-5e15-4433-85ee-ff7bb7218b96"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1155c2c-544c-45f4-969f-b3ec4f6773bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1155c2c-544c-45f4-969f-b3ec4f6773bb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "cca02abb-5240-4ef2-a315-f28e00a41488", "name": "tr(r:p1rdt6578-p1rdt6578lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e257530-1fe2-410b-83a1-57789e6ddeda"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "555453a3-3fb7-426a-bbd2-9e588d4bd01d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "555453a3-3fb7-426a-bbd2-9e588d4bd01d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "82e64de1-effc-4dc0-8ddc-bb009d05dc60", "name": "tr(r:p1rdt6580-p1rdt6580lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68298e92-fca3-44e9-9271-f79be47c9c63"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5de250a8-ecca-4ab4-9f09-685aaf92d13d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5de250a8-ecca-4ab4-9f09-685aaf92d13d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "405b2028-87da-44cf-b232-708b560b6d4b", "name": "tr(r:p1rdt6584-p1rdt6584lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9f273a36-c30d-4962-81f4-26f8d20e1cf4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d944119-3782-49dd-8b24-1f68d8ee687c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d944119-3782-49dd-8b24-1f68d8ee687c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "c275a539-c206-4c1b-b36e-ae22a3bf13dc", "name": "tr(r:p1rdt6587-p1rdt6587lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d77add8e-ba22-4b44-9c0b-0bddc251a573"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c587698-7940-4edb-9105-f31f1304f7e9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c587698-7940-4edb-9105-f31f1304f7e9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "8aca787a-f329-4a51-90aa-09e490eaa499", "name": "tr(r:p1rdt6588-p1rdt6588lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1648fe3-a7f9-47aa-b168-d2b56cf220e7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61045f72-ca3d-4e0d-ac3d-db5fbf099b38"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61045f72-ca3d-4e0d-ac3d-db5fbf099b38"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "95128a03-d470-48ae-9a19-83abda77d90b", "name": "tr(r:p1rdt6590-p1rdt6590lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5291ea2b-6990-407b-b8d4-d6868bf37310"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a289017a-8ab9-4412-857a-694b3aa2c63d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a289017a-8ab9-4412-857a-694b3aa2c63d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "0672aaa6-8f76-454c-95bd-e281f1293e08", "name": "tr(r:p1rdt6591-p1rdt6591lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1d0a85a-62dc-46d2-bae1-d43d07743a34"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a7c2e99-857f-4119-be4a-daaca586f056"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a7c2e99-857f-4119-be4a-daaca586f056"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "43ad826f-468f-4f62-98d4-419243839bab", "name": "tr(r:p1rdt7286-p1rdt7286lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02351140-e632-49e2-83e4-7e5bc1c8856a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ad975da-cce7-49cb-be78-20c4abf8975e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ad975da-cce7-49cb-be78-20c4abf8975e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b64f19d8-c621-4f06-afaa-159a18f970d5", "name": "tr(r:p1rdt7289-p1rdt7289lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f8375b7-7bdd-409c-9fa1-5c13bd233364"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56d21681-3c57-4575-af17-f2bbf9874a10"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56d21681-3c57-4575-af17-f2bbf9874a10"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "f9343681-c623-4b98-830a-4a29714dd9c3", "name": "tr(r:p1rdt7293-p1rdt7293lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4afa9bec-d8da-4449-ab96-9f875bae3c33"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9b0c16f-f433-4aa1-8d00-dc1573dfb5e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9b0c16f-f433-4aa1-8d00-dc1573dfb5e3"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "60823e00-c5b4-4bc4-b042-fad0c40a99f2", "name": "tr(r:p1rdt7294-p1rdt7294lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a955da2d-e212-4026-b1fb-0021a04ded07"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67d2b31-f05a-4160-83ae-55154224a9ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67d2b31-f05a-4160-83ae-55154224a9ca"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "74ab20a7-57a7-4622-ae93-7d3d717abc43", "name": "tr(r:p1rdt7299-p1rdt7299lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d065da7b-7e88-4e63-a47c-959f4d4c6e1c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4cee417a-3410-4907-8621-f0d3fcbc047c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4cee417a-3410-4907-8621-f0d3fcbc047c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "169914f1-885b-4f8c-8e51-c5f5b78521a8", "name": "tr(r:p1rdt7300-p1rdt7300lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05f14a3e-053e-4b65-b962-da7804b9e2c1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "135a6a49-6562-4c6e-a41f-f5f78c0ac3e6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "135a6a49-6562-4c6e-a41f-f5f78c0ac3e6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "de07b9e3-46b7-43d8-be06-8daf46d20cfd", "name": "tr(r:p1rdt7303-p1rdt7303lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6f24e3a-088a-4d1b-8292-03015289d88e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7cbc8145-b198-46f1-a3fd-55a05637e618"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7cbc8145-b198-46f1-a3fd-55a05637e618"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c7531bac-a558-4fc5-abb3-cad5e268ecb0", "name": "tr(r:p1rdt7308-p1rdt7308lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2e605b4-fe7a-4571-947d-8ae19de627d8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5094655-6494-44a9-b0ff-c5b418dcc11e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5094655-6494-44a9-b0ff-c5b418dcc11e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "3d21883c-9d1b-4ac2-882a-5f72cfb7a512", "name": "tr(r:p1rdt7316-p1rdt7316lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6322bf4d-0976-4bae-94c0-f76f83ccb9bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a289e26d-2d86-4fdf-942b-881b91ca18eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a289e26d-2d86-4fdf-942b-881b91ca18eb"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "c412fc0f-8313-41e6-84c6-5d4022182b14", "name": "tr(r:p1rdt7317-p1rdt7317lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48efebbb-c70a-47d3-aae3-0e39088fc455"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16c465cf-c4ae-4702-ba6c-0b7704eda764"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16c465cf-c4ae-4702-ba6c-0b7704eda764"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "fa23fabe-02fd-4549-80aa-192a59aeac79", "name": "tr(r:p1rdt7321-p1rdt7321lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b468be25-1324-46ab-9424-887741ca1134"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c855f7bb-1f33-4c3e-9deb-e3f9c5aba07d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c855f7bb-1f33-4c3e-9deb-e3f9c5aba07d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "94144af1-4cd0-49b9-aa6a-bb93661492f8", "name": "tr(r:p1rdt7737-p1rdt7737lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d2ea25e-3d48-4b1d-9e52-768752de2e09"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35be767a-53a1-4fe1-b320-9542dd859d97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35be767a-53a1-4fe1-b320-9542dd859d97"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "53d064dd-1417-4642-8abf-df6fd0b5bb7b", "name": "tr(r:p1rdt7753-p1rdt7753lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d142315b-a247-4a4d-a178-73e3c150a188"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7482f0c-eb85-4e30-a09a-eb9f15bbc22b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7482f0c-eb85-4e30-a09a-eb9f15bbc22b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "05232de7-0f14-4d8a-8559-1177a07f9e5e", "name": "tr(r:p1rdt7757-p1rdt7757lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "081feb5c-d5d5-405e-85d4-f1dd0916fc3d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d343e634-0936-4f21-9e2c-079e19f0dfa1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d343e634-0936-4f21-9e2c-079e19f0dfa1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "51d1c01e-6f22-46ea-8d46-dd93a1b50d2e", "name": "tr(r:p1rdt7791-p1rdt7791lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4413ca7f-fdd1-484e-a0ba-3ff2447ebfef"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28e5f84f-2fac-4b5c-a669-b16988e4d6ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28e5f84f-2fac-4b5c-a669-b16988e4d6ae"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "eb25695e-13e8-42e0-a678-e5405a877c1f", "name": "tr(r:p1rdt7795-p1rdt7795lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bee93ff6-6ff8-4572-b339-c8e897dac81b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3959f944-18f5-4daa-a454-3c6bfb7158ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3959f944-18f5-4daa-a454-3c6bfb7158ff"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b2fecd2c-00e0-43d7-9dc2-60a9fddea649", "name": "tr(r:p1rdt8105-p1rdt8105lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3f91816-7c3f-4fc7-98a5-6dee55e52e9f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b2ec0ba-a854-4631-b97a-4674123d6fe6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b2ec0ba-a854-4631-b97a-4674123d6fe6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1b65440f-5d1e-4c19-b277-993ab8fb0f7b", "name": "tr(r:p1rdt8111-p1rdt8111lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2c69fef-4afb-4bb3-9828-096b812de54a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b639e55-2e33-4582-bb96-06a9d33a3419"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b639e55-2e33-4582-bb96-06a9d33a3419"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "8183c724-3202-4128-b82b-1bc73f3b6420", "name": "tr(r:p1rdt8138-p1rdt8138lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17b633c6-214d-4428-bded-df737f50ffb6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dca9b40e-ed8a-4f75-a703-91539f6c3075"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dca9b40e-ed8a-4f75-a703-91539f6c3075"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "be148e43-4847-4b1e-a963-f6389733140c", "name": "tr(r:p1rdt8146-p1rdt8146lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc34073b-94f6-4c75-8144-8f624bac9cc7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2bee3961-990e-47ac-b49b-d305f8fe0af8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2bee3961-990e-47ac-b49b-d305f8fe0af8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "dddabe2e-2289-4b4b-a2fc-1b5d8b82f030", "name": "tr(r:p1rdt8167-p1rdt8167lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eb3d4eb-71fc-46f3-b588-d223568c411c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "07bd9128-3c6c-4b6e-a209-1ac8b348eaa9", "name": "tr(r:p1rdt8169-p1rdt8169lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6bdb2cf-9373-4d56-a5f9-cb8fa9c67e55"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6349165a-d47a-4cf4-84f9-df5c5f3a0e98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6349165a-d47a-4cf4-84f9-df5c5f3a0e98"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "3205df5e-6618-4256-9cfd-c5dc7b254caa", "name": "tr(r:p1rdt8174-p1rdt8174lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b0f9433-e0a3-458a-8687-c9cf38d0bbb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4903e82a-8cfb-406e-b4bf-5e01068419a3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4903e82a-8cfb-406e-b4bf-5e01068419a3"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "ae939404-c5bd-43ff-931a-6c0769508bc9", "name": "tr(r:p1rdt8180-p1rdt8180lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c93a476-4ad5-41cd-a07b-e2ccc9ef2c3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8e03b63-853e-4cfe-bf4a-3779b2026637"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8e03b63-853e-4cfe-bf4a-3779b2026637"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "63f53b80-31a5-4067-85a7-637448289748", "name": "tr(r:p1rdt8195-p1rdt8195lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8997dae6-8970-4762-98e9-0617375633d6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "782d6008-7fec-46b6-9461-9e33b79539d3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "782d6008-7fec-46b6-9461-9e33b79539d3"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "0d2d335e-fac3-447e-afe1-00d4234e1208"}}}}, {"uuid": "ce4d8ec3-56e8-4acc-b3b0-dad1fdf76ef5", "name": "tr(r:p1rdt8201-p1rdt8201lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e3d41a7-06a4-460b-aa6c-3a60c8d2de10"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76e33e4f-05be-44d1-a503-fed82b4da974"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76e33e4f-05be-44d1-a503-fed82b4da974"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "4edc8596-210a-4531-a238-d6738acb9e34", "name": "tr(r:p1rdt9055-p1rdt9055lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "246ad62e-5a10-4031-94e7-1732f58f1da9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c1f6cd8-cde1-45cc-87ca-1355efa38077"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c1f6cd8-cde1-45cc-87ca-1355efa38077"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d20d0070-3f40-4462-90d1-9e42dd91adc4", "name": "tr(r:p1rdt9086-p1rdt9086lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75ee3b24-7407-45ba-94d5-abe187306f13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "afb4c195-8bb6-47d5-88f3-76adb9cda250"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "afb4c195-8bb6-47d5-88f3-76adb9cda250"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "766f3347-7aa4-4383-9703-9c0be50e9d7a", "name": "tr(r:p1rdt16394-p1rdt16394lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5b51836-1807-4fab-b877-94a62021569f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40b03cbe-470d-493a-854a-900557ac20c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40b03cbe-470d-493a-854a-900557ac20c8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "40c5e673-05ab-4012-9c8c-7bf871603311", "name": "tr(r:p1rdt16404-p1rdt16404lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61d5dee2-30f8-434d-8c03-76bccff72549"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38b0bd7c-0898-497f-bb24-4add0fd92932"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38b0bd7c-0898-497f-bb24-4add0fd92932"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "e4a24b59-1b02-49fe-8ef5-030327f3023e", "name": "tr(r:p1rdt16424-p1rdt16424lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "18e3da78-83fc-4b8e-9d45-41adb9b753ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23775c66-0b90-443d-8566-491405876e9d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23775c66-0b90-443d-8566-491405876e9d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "484f938d-d59b-4115-9cb2-2685a7b7a2cd", "name": "tr(r:p1rdt16427-p1rdt16427lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d50d3e76-470b-47c2-ada2-da944962b322"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "980376ed-54fd-434c-b58e-0bbd6eaa9954"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "980376ed-54fd-434c-b58e-0bbd6eaa9954"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "449a26bb-c9e0-421e-b94b-a44f94290b59", "name": "tr(r:p1rdt16603-p1rdt16603lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5a9e0f5-d824-4a76-a4f0-88aab072280e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26bc650a-6838-4320-8afa-b8d2f22e96e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26bc650a-6838-4320-8afa-b8d2f22e96e8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "793b342a-db39-473d-bd79-9522eb670aa7", "name": "tr(r:p1rdt16604-p1rdt16604lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98a946e8-3c8a-49ec-be8a-5610c7fc596c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d31da07-e20a-4fb8-95f4-d91450395471"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d31da07-e20a-4fb8-95f4-d91450395471"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "4f26c64f-b8eb-4b58-bb0c-13d80ceb0d14", "name": "tr(r:p1rdt16787-p1rdt16787lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4bc644c-9875-4846-8b0f-dfa0568de623"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4a3b828-bddf-4314-b9a5-03b9dfcd2618"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4a3b828-bddf-4314-b9a5-03b9dfcd2618"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "76b84fae-6335-4869-b08d-8984583dd282", "name": "tr(r:p1rdt16790-p1rdt16790lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4774ed1a-85ec-4ca0-8e9a-3b232588fb0c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c261090-bc22-4d81-9a9e-75227cd7c99e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c261090-bc22-4d81-9a9e-75227cd7c99e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "857e2066-6f60-4b44-8d3c-02354b5fd872", "name": "tr(r:p1rdt16847-p1rdt16847lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e35a4f7-19c1-4f59-9adc-b267f6088264"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1abef1d-4ffc-4696-91ca-e81ac36cce61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1abef1d-4ffc-4696-91ca-e81ac36cce61"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "383a2c28-1707-4345-a2fd-dd5fc492cc54", "name": "tr(r:p1rdt16911-p1rdt16911lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "725fbd98-74ba-4143-8947-da9fdc209889"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0df1550a-7e69-42e9-8059-3a36ecb3d253"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0df1550a-7e69-42e9-8059-3a36ecb3d253"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a2ab4202-af90-45ce-b38a-724c78d23cda", "name": "tr(r:p1rdt7711-p1rdt7711lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2131350-dc34-4d8d-8c9f-c29e25bc654c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64b60527-0853-4973-8d7a-78ba5e377799"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "d0a1b468-f2c0-460e-b454-e11535f6f969", "name": "tr(r:p1rdt8473-p1rdt8473lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3a83211-0829-4e2c-b618-3f1fcaba3e87"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "439728c5-fee5-4dfa-9894-261ba6c40e95"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "6ebf15d5-5f87-45c8-b7ce-35edd541c885", "name": "tr(r:p1rdt6028-p1rdt6028lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e39cb1db-d6a6-4b6c-bc73-920e0c34c292"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35f6f747-811d-4fe2-a9c7-991248572c74"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "df70495a-02d7-450a-9a65-9e0b6b42b83f", "name": "tr(r:p1rdt9478-p1rdt9478lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c49b6e87-5834-4e7e-a64c-b4ec0f7d4995"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddf38626-1223-429f-a903-98f1c975020b"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "c3da3337-5527-44f4-b208-3bbfe346a0fe", "name": "tr(r:p1rdt6232-p1rdt6232lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b59ad93a-cca2-4a77-8515-a645ddd2a320"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e2630e1-a215-4740-9327-fa004e89863d"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "68bf215e-2a75-42a5-be1c-54396a95a2cf", "name": "tr(r:p1rdt8493-p1rdt8493lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A", "B", "C"], ["A", "B", "C"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfb41891-7063-44b8-9286-1fe763e49924"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c330731a-fd2c-40c7-8fce-94f7e17cf6d9"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "f9846bf3-0a51-4e0e-b72a-d0c65f44bc39"}}}}, {"uuid": "21c9d6f7-778e-45ae-9eee-c04828838596", "name": "tr(r:p1rdt93-p1rdt93lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["B"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "900d49ce-4834-4f99-8d74-a5e9d2f63ea0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0921e58d-1ada-4556-8b01-8f22d3bf4ee2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0921e58d-1ada-4556-8b01-8f22d3bf4ee2"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e2f53d7d-7442-4b42-8617-11656e408189"}}}}, {"uuid": "4987fad3-04f3-4a44-9e95-4c76bb8da481", "name": "tr(r:p1rdt99-p1rdt99lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "092a9d51-a39c-4c05-905e-93fb1ae96ba2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef6be92d-5d1b-40e2-a2c2-9d0c1f0bf596"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef6be92d-5d1b-40e2-a2c2-9d0c1f0bf596"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "66884d82-d8ad-43ea-b952-5bef9472cc31", "name": "tr(r:p1rdt101-p1rdt101lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d8e5d83-cd9c-4527-9eef-6219c98dfe93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1277a701-9fbd-4853-a809-962475e016c4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1277a701-9fbd-4853-a809-962475e016c4"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "b91fce2e-6543-43ed-b024-f99717df76a9", "name": "tr(r:p1rdt108-p1rdt108lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e61ce952-a643-45aa-a466-8aa15ecceb48"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3aa8d6f2-8d84-42d6-8e7b-89e3b1efa03c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3aa8d6f2-8d84-42d6-8e7b-89e3b1efa03c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "d4442785-5a57-40fb-9428-4491355af6e1", "name": "tr(r:p1rdt6121-p1rdt6121lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2390c014-d418-4d63-8438-529a036487db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "448cc5e0-391f-4a6b-8199-25cef4593edf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "448cc5e0-391f-4a6b-8199-25cef4593edf"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "59985662-1964-4761-9713-7d3f9e638929", "name": "tr(r:p1rdt6123-p1rdt6123lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17f807ba-6ad6-4fd9-9dd0-2c0bacea5b24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e81ba94-5857-42e4-aeee-58542cef0fb6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e81ba94-5857-42e4-aeee-58542cef0fb6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "afa627b8-bda7-4883-9053-6fe4ad39ebd2", "name": "tr(r:p1rdt8017-p1rdt8017lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6378abd-969e-4ec8-93eb-2cc39cdb18eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8428de0e-4b06-4f19-bffb-5fed32f96f67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8428de0e-4b06-4f19-bffb-5fed32f96f67"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "101e3b64-572d-4af1-b520-d6b982c7e99e", "name": "tr(r:p1rdt8043-p1rdt8043lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "691c1909-3b71-4e07-abf0-95aaabfa23bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a367e687-b29a-44b4-a943-7b94762e549e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a367e687-b29a-44b4-a943-7b94762e549e"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "b52a1ec1-eb6d-4410-9a09-fb90b84cc806", "name": "tr(r:p1rdt8065-p1rdt8065lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "862f3566-9443-4b82-8f05-c994581e131a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8bb025c5-31eb-4771-b433-e1dcad03b3ed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8bb025c5-31eb-4771-b433-e1dcad03b3ed"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "ac790f59-9dc9-42c3-b7b0-7e682faa07f7", "name": "tr(r:p1rdt8068-p1rdt8068lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f5fbb8b-0c32-4aa7-acaf-7ea2b5e56505"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd01eed6-0e70-42e7-ac29-4bfd2f70366a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd01eed6-0e70-42e7-ac29-4bfd2f70366a"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a999665e-c3af-4abd-a73a-56e5afe42a96", "name": "tr(r:p1rdt8070-p1rdt8070lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473520c7-0098-4bc2-a46f-07efd6c3759c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0bcd460-ccf2-42ee-83c6-bada397ab4d6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0bcd460-ccf2-42ee-83c6-bada397ab4d6"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "fc204377-0430-4e39-92d8-12637b9626bd"}}}}, {"uuid": "ff4316bf-2fdf-402e-933a-1d92eec8d30e", "name": "tr(r:p1rdt8190-p1rdt8190lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a761aef-a766-40e2-b8d7-e5a918cece18"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f21f4e99-8877-4bb0-9956-9240bc6db3d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f21f4e99-8877-4bb0-9956-9240bc6db3d1"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1fa55d6c-fec8-4ebc-baad-a862692ee4e1", "name": "tr(r:p1rdt8204-p1rdt8204lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa2342e6-2d40-424a-830c-a84af4632b6e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d12bf6fb-8dac-4729-bcda-1ee61c63f6e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d12bf6fb-8dac-4729-bcda-1ee61c63f6e8"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "029066e1-edb3-4a44-997d-76fbe7264dd0", "name": "tr(r:p1rdt8208-p1rdt8208lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e2b4d77-2388-4897-86fe-06409fa9d222"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ecf11723-eb6d-423c-ac0c-85fa2d1ba846"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ecf11723-eb6d-423c-ac0c-85fa2d1ba846"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "6a8d6f6f-b19a-43dc-a86f-18dfc67b7451", "name": "tr(r:p1rdt8578-p1rdt8578lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb866499-9e9c-4394-bd76-d4320ba4934b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1a593e3-4735-47d2-b893-dd2d07c3c47c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1a593e3-4735-47d2-b893-dd2d07c3c47c"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "1a547192-d0a9-4174-8c47-f8a34d6a8321", "name": "tr(r:p1rdt8583-p1rdt8583lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dbb79e10-21ba-4f04-b8a3-0cf711d26d40"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "134bac3d-5b7e-48d7-950e-01e5b7d43852"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "134bac3d-5b7e-48d7-950e-01e5b7d43852"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "d5409af6-e60a-4f61-af90-35c4c7a32310", "name": "tr(r:p1rdt8584-p1rdt8584lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["C"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b601580-3091-4d8c-9718-1367c7ed385f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8ba1042-fcfd-47a8-aa0f-8b13618d3212"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8ba1042-fcfd-47a8-aa0f-8b13618d3212"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "21bda883-4037-4b29-95fc-2e5d0c901e4e", "name": "tr(r:p1rdt10491-p1rdt10491lv)", "substation": null, "feeder": null, "in_service": true, "winding_phases": [["A"], ["S1", "N"], ["S2", "N"]], "__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_transformer", "type": "DistributionTransformer", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4737e613-8cf5-45d7-a3f5-71af051ece4c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8f14e6e-ee96-4ae9-86ba-4a07cf103b65"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8f14e6e-ee96-4ae9-86ba-4a07cf103b65"}}}], "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.distribution_transformer_equipment", "type": "DistributionTransformerEquipment", "serialized_type": "composed_component", "uuid": "e3032dbd-f148-4333-a39b-4f358ab6cc39"}}}}, {"uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482", "name": "", "limit_type": "max", "__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "base"}}, "value": {"value": 600.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}}, {"uuid": "d17ac250-39de-4755-ab93-d93c9ffec1f4", "name": "3974db24-e8e2-4dea-b6b3-1ce29ed132c9", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 1200.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "33fd2b05-630e-42ac-9ccf-60a8ee3f45c9", "name": "7273acf0-19b9-4e4c-b23c-268bdb215a51", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 900.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "14ee131a-95b9-49c5-b11d-450705732a22", "name": "51a33b90-9eee-4646-b0aa-862f7255c6b3", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 165.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "6ba5defb-3101-4ef8-8d06-36719f7dad94", "name": "27d4ced8-b2f8-4ebb-af19-64e0d6a72831", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 151.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "fa89ef5e-f965-457f-a553-4831f61b03c7", "name": "c53fbbfe-4cda-4768-ab94-259d70acb568", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 301.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "cbd826fb-5ba3-44b3-9c68-e5792dbd9854", "name": "62927506-2fbe-4764-b56a-e2ec536f5a4d", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 205.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "99530725-fc4c-4216-8e67-a4469035c280", "name": "0c3473a8-3f24-4fba-b819-b37916068d57", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 295.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523", "name": "179bf9a8-7aaa-4d22-8e36-ca540eaba4ff", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 325.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "fc796329-2b2a-43b9-80c9-88427ef9b994", "name": "0806190a-92f7-42c1-b527-04504919e640", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 233.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "4900e609-ebb1-44db-852b-602449095f15", "name": "5df7dfb1-43ab-41a2-9a13-560098cbf260", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 205.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "40a26197-da2a-4e22-a50a-3922efd7762c", "name": "08f3b6b5-1bbd-40e6-8b34-a1d59d7b57e2", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0412]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.7627]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[7.69673]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 165.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "3baa725a-9b39-45f8-86af-c6afda2cdf9f", "name": "92be5f47-025f-41ac-a0e4-09323ff980fd", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "2419ddcd-627b-4faa-9878-65d4baf7d064", "name": "c9f25e4e-fbf4-4152-a503-2fdd1553b4c9", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "ab2720f4-bdaa-4e93-a718-9d3398ce76a4", "name": "840ea5ca-ca79-4640-abfc-a248810bef2f", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 301.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "c01372a2-4296-4877-a1f3-dd8c06d37f74", "name": "f3d3a255-32e5-4fb0-9516-d898bf9ec850", "controller": null, "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1.0, 0.0, 0.0], [0.0, 1.0, 0.0], [0.0, 0.0, 1.0]], "units": "ohm / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[1.0666666666666669, -0.03333333333333336, -0.03333333333333336], [-0.03333333333333336, 1.0666666666666669, -0.03333333333333336], [-0.03333333333333336, -0.03333333333333336, 1.0666666666666669]], "units": "nanofarad / meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 370.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "42f228c5-d3cc-4ea7-9d1c-029acf33213c", "name": "3p_oh_code_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.22464633333333334, 0.05016533333333334, 0.05016533333333334], [0.05016533333333334, 0.22464633333333334, 0.05016533333333334], [0.05016533333333334, 0.05016533333333334, 0.22464633333333334]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.631065, 0.188089, 0.188089], [0.188089, 0.631065, 0.188089], [0.188089, 0.188089, 0.631065]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[2.8000000000000003, -0.6, -0.6], [-0.6, 2.8000000000000003, -0.6], [-0.6, -0.6, 2.8000000000000003]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 480.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "72184ad1-d36c-4223-8c4b-6bdd0563907c", "name": "breaker_13kv_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1e-05, 0.0, 0.0], [0.0, 1e-05, 0.0], [0.0, 0.0, 1e-05]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1e-05, 0.0, 0.0], [0.0, 1e-05, 0.0], [0.0, 0.0, 1e-05]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[2.8000000000000003, -0.6, -0.6], [-0.6, 2.8000000000000003, -0.6], [-0.6, -0.6, 2.8000000000000003]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 1200.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "9faab192-2f24-4afc-9a9c-210e7b431e38", "name": "breaker_69kv_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1e-05, 0.0, 0.0], [0.0, 1e-05, 0.0], [0.0, 0.0, 1e-05]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[1e-05, 0.0, 0.0], [0.0, 1e-05, 0.0], [0.0, 0.0, 1e-05]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[2.8000000000000003, -0.6, -0.6], [-0.6, 2.8000000000000003, -0.6], [-0.6, -0.6, 2.8000000000000003]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 900.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0", "name": "1p_oh_al_4_periwinkle_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.7609666666666666, 0.3959666666666668], [0.3959666666666668, 1.7609666666666666]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.6698333333333334, 0.5686333333333333], [0.5686333333333333, 0.6698333333333334]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[36.92503333333334, -17.558966666666667], [-17.558966666666667, 36.92503333333334]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934", "name": "1p_oh_al_4/0_zuzara_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.4728, 0.20209999999999997], [0.20209999999999997, 0.4728]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.21353333333333335, 0.12473333333333335], [0.12473333333333335, 0.21353333333333335]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[41.3578, -20.447400000000002], [-20.447400000000002, 41.3578]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580", "name": "1p_oh_al_2/0_rucina_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.7166333333333332, 0.28753333333333336], [0.28753333333333336, 0.7166333333333332]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.28883333333333333, 0.1932333333333333], [0.1932333333333333, 0.28883333333333333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[39.3595, -19.342100000000002], [-19.342100000000002, 39.3595]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "2d347746-0969-4a8a-b986-c40ef4f4c015", "name": "1p_oh_al_2/0_rucina_2_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.7166333333333332, 0.28753333333333336], [0.28753333333333336, 0.7166333333333332]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.28883333333333333, 0.1932333333333333], [0.1932333333333333, 0.28883333333333333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[39.3595, -19.342100000000002], [-19.342100000000002, 39.3595]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 300.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f", "name": "1p_ug_al_1/0_brenau_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.9149, 0.3744], [0.3744, 0.9149]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.4972667, 0.3969667], [0.3969667, 0.4972667]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[36.4998, -16.313099999999995], [-16.313099999999995, 36.4998]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 205.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "09abe480-4eaa-43f7-a172-88856f758284", "name": "1p_oh_al_2/0_rucina_2_5", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.7166333333333332, 0.28753333333333336], [0.28753333333333336, 0.7166333333333332]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.28883333333333333, 0.1932333333333333], [0.1932333333333333, 0.28883333333333333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[39.3595, -19.342100000000002], [-19.342100000000002, 39.3595]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 233.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "3c9c08f9-58e9-4367-aee8-72788caa6a7c", "name": "1p_ug_al_2/0_converse_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.7793333, 0.3503333], [0.3503333, 0.7793333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.4209333, 0.3231333], [0.3231333, 0.4209333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[37.42527, -17.11183], [-17.11183, 37.42527]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 233.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398", "name": "1p_ug_al_4/0_sweetbriar_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.5462333, 0.2755333], [0.2755333, 0.5462333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.2976, 0.2043], [0.2043, 0.2976]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[39.3278, -18.6046], [-18.6046, 39.3278]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 301.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "97e8fcf2-7304-40bf-ae9b-e7cdd37a4fb7", "name": "1p_oh_al_4/0_zuzara_2_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.4728, 0.20209999999999997], [0.20209999999999997, 0.4728]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.21353333333333335, 0.12473333333333335], [0.12473333333333335, 0.21353333333333335]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[41.3578, -20.447400000000002], [-20.447400000000002, 41.3578]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 165.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "52d0c8fb-a66f-4033-93f4-79e9ae946d79", "name": "1p_oh_al_2/0_rucina_2_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.7166333333333332, 0.28753333333333336], [0.28753333333333336, 0.7166333333333332]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.28883333333333333, 0.1932333333333333], [0.1932333333333333, 0.28883333333333333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[39.3595, -19.342100000000002], [-19.342100000000002, 39.3595]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 165.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137", "name": "1p_oh_al_acsr_#2_sparrow_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[1.0412]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.7627]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[7.69673]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 165.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "1369a137-ea26-496f-a49e-07fe1c36db1c", "name": "1p_ug_al_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.9176999999999998]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.9546999999999999]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[158.492]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 151.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "6148f90f-6cfa-4038-a641-2905e51ba219", "name": "3p_oh_al_acsr_4/0_penguin_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.3635667, 0.09006667, 0.09006667], [0.09006667, 0.3635667, 0.09006667], [0.09006667, 0.09006667, 0.3635667]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.6385333, 0.2202333, 0.2202333], [0.2202333, 0.6385333, 0.2202333], [0.2202333, 0.2202333, 0.6385333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[7.4482669999999995, -3.1846329999999994, -3.1846329999999994], [-3.1846329999999994, 7.4482669999999995, -3.1846329999999994], [-3.1846329999999994, -3.1846329999999994, 7.4482669999999995]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 325.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "39368021-558c-46e1-b3b2-1376e7863046", "name": "3p_ug_al_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.3289333, 0.05923333, 0.05923333], [0.05923333, 0.3289333, 0.05923333], [0.05923333, 0.05923333, 0.3289333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.9076, 0.6647, 0.6647], [0.6647, 0.9076, 0.6647], [0.6647, 0.6647, 0.9076]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[120.289, -59.026, -59.026], [-59.026, 120.289, -59.026], [-59.026, -59.026, 120.289]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 295.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9", "name": "3p_ug_al_350kcmil_3_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.3388667, 0.1744667, 0.1744667], [0.1744667, 0.3388667, 0.1744667], [0.1744667, 0.1744667, 0.3388667]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.5126, 0.2912, 0.2912], [0.2912, 0.5126, 0.2912], [0.2912, 0.2912, 0.5126]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[164.36499999999998, -81.63499999999999, -81.63499999999999], [-81.63499999999999, 164.36499999999998, -81.63499999999999], [-81.63499999999999, -81.63499999999999, 164.36499999999998]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 370.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "3bc006be-04ae-45f9-8629-fd4cc42dcf20", "name": "3p_oh_al_acsr_1033kcmil_curlew_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.0871, 0.0296, 0.0296], [0.0296, 0.0871, 0.0296], [0.0296, 0.0296, 0.0871]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.5382333, 0.1839333, 0.1839333], [0.1839333, 0.5382333, 0.1839333], [0.1839333, 0.1839333, 0.5382333]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[8.6745, -3.8842, -3.8842], [-3.8842, 8.6745, -3.8842], [-3.8842, -3.8842, 8.6745]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 960.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "5c14e22a-39e2-4cbb-9aec-056684ef40fa", "name": "padswitch_1_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 165.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "b97451c9-daac-45bb-a300-842ddcc87c76", "name": "padswitch_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 151.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "71edde96-3e63-4b16-8a12-0f7c3c2771f1", "name": "padswitch_1_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 301.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "6b25b103-d37c-42ce-9c2a-4fed44a4146e", "name": "padswitch_1_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 205.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "b8abe50a-d021-449e-a17c-f73c1142aee4", "name": "padswitch_3_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.499563, -0.1093613, -0.1093613], [-0.1093613, 3.499563, -0.1093613], [-0.1093613, -0.1093613, 3.499563]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 295.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "140f67fe-0cf8-45a3-8e1d-7cd225dab6f1", "name": "padswitch_3_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.499563, -0.1093613, -0.1093613], [-0.1093613, 3.499563, -0.1093613], [-0.1093613, -0.1093613, 3.499563]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 325.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "6ef66588-c56f-4ab4-8152-a7ceffd19280", "name": "padswitch_3_8", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.499563, -0.1093613, -0.1093613], [-0.1093613, 3.499563, -0.1093613], [-0.1093613, -0.1093613, 3.499563]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 233.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "e6fb8431-c064-4a3e-8d04-97f3fe67c4bb", "name": "padswitch_3_2", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.499563, -0.1093613, -0.1093613], [-0.1093613, 3.499563, -0.1093613], [-0.1093613, -0.1093613, 3.499563]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 205.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "bb659552-de29-4980-948f-b0934dad487c", "name": "fuse_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 325.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "7428d9ad-6003-41e1-acc5-c6e01cb8cae2", "name": "fuse_1_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 165.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "dc9b42df-2b7f-4193-8152-ae871c971371", "name": "fuse_1_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "a0d4e32b-8224-4708-b512-715f8a126cff", "name": "fuse_1_6", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 295.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "1afe4efd-d8e8-446b-970c-e6ba75da4e22", "name": "fuse_1_9", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 233.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "0fcbf486-ed39-4481-96a7-243f013e9f46", "name": "padswitch_1_4", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.608924]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "b8590a64-3624-43d1-8279-40a7928d98a9", "name": "padswitch_3_6", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.499563, -0.1093613, -0.1093613], [-0.1093613, 3.499563, -0.1093613], [-0.1093613, -0.1093613, 3.499563]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "1cf20eb0-ac1f-4a6f-882e-a5d94dfb8dcb", "name": "padswitch_3_9", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.499563, -0.1093613, -0.1093613], [-0.1093613, 3.499563, -0.1093613], [-0.1093613, -0.1093613, 3.499563]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 301.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "bf5bc40f-4332-47bf-baf6-f15771c7e420", "name": "padswitch_3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001, 0.0, 0.0], [0.0, 0.001, 0.0], [0.0, 0.0, 0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.499563, -0.1093613, -0.1093613], [-0.1093613, 3.499563, -0.1093613], [-0.1093613, -0.1093613, 3.499563]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 370.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "39499f7e-f729-4218-afda-ccccc72332f9", "name": "fuse_1_5", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 370.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b", "name": "3p_ug_al_3_1", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.445, 0.1745, 0.1745], [0.1745, 0.445, 0.1745], [0.1745, 0.1745, 0.445]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.5326, 0.2912, 0.2912], [0.2912, 0.5326, 0.2912], [0.2912, 0.2912, 0.5326]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[145.291, -72.088, -72.088], [-72.088, 145.291, -72.088], [-72.088, -72.088, 145.291]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 285.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}}, {"uuid": "e7b097f2-bcb0-4abe-b9b3-be9ec78c74f4", "name": "", "__metadata__": {"fields": {"module": "gdm.distribution.curve", "type": "TimeCurrentCurve", "serialized_type": "base"}}, "curve_x": {"value": [2.0, 2.1, 3.0, 4.0, 6.0, 22.0, 50.0], "units": "ampere", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Current", "serialized_type": "quantity"}}}, "curve_y": {"value": [300.0, 100.0, 10.1, 4.0, 1.4, 0.1, 0.02], "units": "second", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Time", "serialized_type": "quantity"}}}}, {"uuid": "d467095a-575e-4fb7-991f-4e2cdf643318", "name": "56320575-cdcc-4544-a3e7-3bcae477af01", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 325.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}, "delay": {"value": 0.0, "units": "second", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Time", "serialized_type": "quantity"}}}, "tcc_curve": {"__metadata__": {"fields": {"module": "gdm.distribution.curve", "type": "TimeCurrentCurve", "serialized_type": "composed_component", "uuid": "e7b097f2-bcb0-4abe-b9b3-be9ec78c74f4"}}}}, {"uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770", "name": "f7b2bfa1-8c77-4b62-850d-04620d3799e4", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 165.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}, "delay": {"value": 0.0, "units": "second", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Time", "serialized_type": "quantity"}}}, "tcc_curve": {"__metadata__": {"fields": {"module": "gdm.distribution.curve", "type": "TimeCurrentCurve", "serialized_type": "composed_component", "uuid": "e7b097f2-bcb0-4abe-b9b3-be9ec78c74f4"}}}}, {"uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482", "name": "fb7f7907-38db-42f7-a652-427c0c9d518c", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 115.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}, "delay": {"value": 0.0, "units": "second", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Time", "serialized_type": "quantity"}}}, "tcc_curve": {"__metadata__": {"fields": {"module": "gdm.distribution.curve", "type": "TimeCurrentCurve", "serialized_type": "composed_component", "uuid": "e7b097f2-bcb0-4abe-b9b3-be9ec78c74f4"}}}}, {"uuid": "861d64ae-aba6-4135-a3ca-f177438722a2", "name": "c44effc4-af4a-4a90-ba5f-b9ab992a2b0c", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 295.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}, "delay": {"value": 0.0, "units": "second", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Time", "serialized_type": "quantity"}}}, "tcc_curve": {"__metadata__": {"fields": {"module": "gdm.distribution.curve", "type": "TimeCurrentCurve", "serialized_type": "composed_component", "uuid": "e7b097f2-bcb0-4abe-b9b3-be9ec78c74f4"}}}}, {"uuid": "ab93cbf0-52fd-4d3d-a7f9-fd7cb4376fa6", "name": "291ce2f8-f492-4cb6-8b07-5df217ca3f92", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 233.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}, "delay": {"value": 0.0, "units": "second", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Time", "serialized_type": "quantity"}}}, "tcc_curve": {"__metadata__": {"fields": {"module": "gdm.distribution.curve", "type": "TimeCurrentCurve", "serialized_type": "composed_component", "uuid": "e7b097f2-bcb0-4abe-b9b3-be9ec78c74f4"}}}}, {"uuid": "73f75b89-55b4-4a16-9fa1-8771daf3d5be", "name": "8d08090f-ee79-4f79-9907-9e6c53c590a3", "__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "base"}}, "r_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ResistancePULength", "serialized_type": "quantity"}}}, "x_matrix": {"value": [[0.001]], "units": "ohm / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "ReactancePULength", "serialized_type": "quantity"}}}, "c_matrix": {"value": [[3.4]], "units": "nanofarad / kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "CapacitancePULength", "serialized_type": "quantity"}}}, "ampacity": {"value": 370.0, "units": "ampere", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Current", "serialized_type": "quantity"}}}, "loading_limit": {"__metadata__": {"fields": {"module": "gdm.distribution.limitset", "type": "ThermalLimitSet", "serialized_type": "composed_component", "uuid": "a5e8c419-17ba-4c12-ae50-19c6f9ccb482"}}}, "delay": {"value": 0.0, "units": "second", "__metadata__": {"fields": {"module": "infrasys.quantities", "type": "Time", "serialized_type": "quantity"}}}, "tcc_curve": {"__metadata__": {"fields": {"module": "gdm.distribution.curve", "type": "TimeCurrentCurve", "serialized_type": "composed_component", "uuid": "e7b097f2-bcb0-4abe-b9b3-be9ec78c74f4"}}}}, {"uuid": "29ee0e2a-8445-4b4f-89fe-d9e9555d89de", "name": "sb10_p1rhs7_1247_311", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30052484-94f2-43a3-abb7-9314d4593c20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ed5e3889-e8c8-4215-adb8-9880f8937da5"}}}], "length": {"value": 0.001511744, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "42f228c5-d3cc-4ea7-9d1c-029acf33213c"}}}}, {"uuid": "bac6250f-86a5-4f43-ac97-3014374e1458", "name": "sb10_p1rhs7_1247_313", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23779a0d-9859-4591-b4ce-7ec704401d42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1548dd91-bc3d-4a2c-903f-48e11159c558"}}}], "length": {"value": 0.001511744, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "42f228c5-d3cc-4ea7-9d1c-029acf33213c"}}}}, {"uuid": "fdee7cd2-4531-4679-9430-6cddbb1eda85", "name": "sb10_p1rhs7_1247_310", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4d9a6e8-eb1b-454c-ae94-2eb435218fb9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14208aa5-3197-4c90-adf9-3067dae9b5f9"}}}], "length": {"value": 0.002267616, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "42f228c5-d3cc-4ea7-9d1c-029acf33213c"}}}}, {"uuid": "516b4490-8d2f-4ed7-8c42-cc189f1caec0", "name": "sb10_p1rhs7_1247_312", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2427b8de-af1a-44f8-9774-724e635057fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec7726f8-0afb-4c35-8a1b-0691a8fb400d"}}}], "length": {"value": 0.002267616, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "42f228c5-d3cc-4ea7-9d1c-029acf33213c"}}}}, {"uuid": "acbd5efd-6ad5-4648-8703-0efb1a4b5dd9", "name": "sb10_p1rhs7_1247_354", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "001adbd4-6616-4dce-83d2-025e896ada51"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3856ea8d-83da-4d2e-8f66-fae6c69b5db1"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "d17ac250-39de-4755-ab93-d93c9ffec1f4"}}}}, {"uuid": "2e5e0aa8-9e09-438d-b554-36c2e72760e7", "name": "sb10_p1rhs7_1247_307", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c975b603-30a6-4ed1-bbae-696d1c5b0a3d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23779a0d-9859-4591-b4ce-7ec704401d42"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "d17ac250-39de-4755-ab93-d93c9ffec1f4"}}}}, {"uuid": "5ce19f15-a792-442e-a7fa-fac766595642", "name": "sb10_p1rhs7_1247_305", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6263cae0-e97a-4044-a130-e971a626d3c1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30052484-94f2-43a3-abb7-9314d4593c20"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "d17ac250-39de-4755-ab93-d93c9ffec1f4"}}}}, {"uuid": "7c2d9b1a-6e34-47c2-acf6-91b80aa94d66", "name": "sb10_p1rhs7_1247_303", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3856ea8d-83da-4d2e-8f66-fae6c69b5db1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c975b603-30a6-4ed1-bbae-696d1c5b0a3d"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "d17ac250-39de-4755-ab93-d93c9ffec1f4"}}}}, {"uuid": "069db73a-656d-42e0-906b-02395eb7257b", "name": "sb10_p1rhs7_1247_347", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16bb904e-b153-4b0a-97f5-53ad7c6606d8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ca7962b4-686c-4bee-af8d-f1851b835adb"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "33fd2b05-630e-42ac-9ccf-60a8ee3f45c9"}}}}, {"uuid": "a60ebb51-1b37-43c3-859c-de42675fe34f", "name": "sb10_p1rhs7_1247_306", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c975b603-30a6-4ed1-bbae-696d1c5b0a3d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2427b8de-af1a-44f8-9774-724e635057fb"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "d17ac250-39de-4755-ab93-d93c9ffec1f4"}}}}, {"uuid": "ffaf79ca-5c18-46fc-b1af-dc55f22795b8", "name": "sb10_p1rhs7_1247_304", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6263cae0-e97a-4044-a130-e971a626d3c1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4d9a6e8-eb1b-454c-ae94-2eb435218fb9"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "d17ac250-39de-4755-ab93-d93c9ffec1f4"}}}}, {"uuid": "a2e353c7-8d1a-4863-a935-f26557420635", "name": "sb10_p1rhs7_1247_349", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ca7962b4-686c-4bee-af8d-f1851b835adb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "574ab810-c1b0-4662-8c4d-f32ab6893a36"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "33fd2b05-630e-42ac-9ccf-60a8ee3f45c9"}}}}, {"uuid": "ecd0c793-0eab-4a56-992b-f4cdf28c9fb5", "name": "sb10_p1rhs7_1247_302", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3856ea8d-83da-4d2e-8f66-fae6c69b5db1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6263cae0-e97a-4044-a130-e971a626d3c1"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "d17ac250-39de-4755-ab93-d93c9ffec1f4"}}}}, {"uuid": "a596de2d-c583-495c-8e87-684ff992d13b", "name": "l(r:p1rdt4964lv-p1rlv10170)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3541a1a-9680-4baf-9b87-a1322cb1a16a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02e86824-b793-4080-9401-c6995a365baf"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "9679fe35-fbbc-45a3-973d-24b473884602", "name": "l(r:p1rdt4980lv-p1rlv10189)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab731358-e17f-4c48-b6f8-c7bb4c7701de"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58f2b2c3-4f6f-4fd2-abb9-42ff665692bd"}}}], "length": {"value": 0.0491385, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ba04e182-afcb-48fa-9746-2e11559cb473", "name": "l(r:p1rdt4980lv-p1rlv10574)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab731358-e17f-4c48-b6f8-c7bb4c7701de"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b4caeee-6304-4a25-a7d8-44c6014b5e37"}}}], "length": {"value": 0.0298046, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "228b5f7b-dac5-4b0e-b0b1-3a389c3dc040", "name": "l(r:p1rdt4980lv-p1rlv10596)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab731358-e17f-4c48-b6f8-c7bb4c7701de"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aad9ea92-9403-4ac0-9aaf-7e845b8c7bb5"}}}], "length": {"value": 0.0197463, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6c6b3bb5-9c25-4716-a167-aace2b875e2e", "name": "l(r:p1rdt5017lv-p1rlv10262)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0375d197-ccd2-4ed8-9439-857b700cefb8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3317d7c2-2588-426d-91fc-3d765b932da6"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "e4d5b6e9-1c05-4376-8081-8308282a46d2", "name": "l(r:p1rdt5126lv-p1rlv10491)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e33e473-8d5b-4704-bdab-56032991f94e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f7116b9-96c1-42c8-850f-7787f5fd0f96"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "fbef4d18-a197-429d-828d-09390792d6c2", "name": "l(r:p1rdm10619-p1rlv10521)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd4b469b-001b-4914-8e51-e98fe3f6babb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31f26b28-fc9d-4b3d-b204-cf40f3478c44"}}}], "length": {"value": 0.0680764, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "148f5acc-b8c0-4d21-a617-7244a63c718e", "name": "l(r:p1rdm10620-p1rlv10641)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e28a5f3a-4447-469a-85dd-e232d8c6d728"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73ada6ad-ace7-46c1-80f7-2cb33cf4cdb3"}}}], "length": {"value": 0.03407530000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "45d46b87-bb36-48a2-8d53-0a55675034bf", "name": "l(r:p1rdm10619-p1rdm10620)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd4b469b-001b-4914-8e51-e98fe3f6babb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e28a5f3a-4447-469a-85dd-e232d8c6d728"}}}], "length": {"value": 0.0178464, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f38d4a07-13c3-4b95-ae7c-7c6b7d041360", "name": "l(r:p1rdm10619-p1rdt5140lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f114a56-98d7-4fe8-b0b1-b8c4bc791cf9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd4b469b-001b-4914-8e51-e98fe3f6babb"}}}], "length": {"value": 0.0178464, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "2d347746-0969-4a8a-b986-c40ef4f4c015"}}}}, {"uuid": "d351709b-972b-4d55-8d6e-f82dce2d848d", "name": "l(r:p1rdm10621-p1rlv20071)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e09d217e-44a5-4013-8d48-8546d6bb1dc3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07f95ba5-92dd-465f-a38d-8e878243262b"}}}], "length": {"value": 0.0125414, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6b760518-573f-4b9d-a363-83b3bb356359", "name": "l(r:p1rdm10621-p1rdt5140lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f114a56-98d7-4fe8-b0b1-b8c4bc791cf9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e09d217e-44a5-4013-8d48-8546d6bb1dc3"}}}], "length": {"value": 0.0178464, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ec0ee5c6-d17f-48f6-bfe3-c14274d5bfb6", "name": "l(r:p1rdt5142lv-p1rlv10523)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e071635-4071-470d-be09-4484cb90441a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35d47036-a044-4c67-b5b5-0006e2a3b68e"}}}], "length": {"value": 0.019072, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8bc645f7-1f0e-434d-bacc-53e73e4258fe", "name": "l(r:p1rdt5142lv-p1rlv10616)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e071635-4071-470d-be09-4484cb90441a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a5717e0-080e-46ae-918a-64fe4fcba5d7"}}}], "length": {"value": 0.019072, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "587cec7d-7000-4cf3-9010-3f39f71a3747", "name": "l(r:p1rdt5153lv-p1rlv10538)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ec20ad2-b04f-43fc-ad8d-d41746549a57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a302271d-4cf3-45ff-9308-b9cf31fbefa3"}}}], "length": {"value": 0.052564700000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "ebfd9db5-3ac9-4827-98f7-d190caca7cdf", "name": "l(r:p1rdt5153lv-p1rlv10586)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ec20ad2-b04f-43fc-ad8d-d41746549a57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfbe5665-c020-455a-addc-d3f9514735ed"}}}], "length": {"value": 0.0379881, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "d76eb6de-93b6-410f-955e-c8305a62dbe6", "name": "l(r:p1rdt5153lv-p1rlv10610)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ec20ad2-b04f-43fc-ad8d-d41746549a57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b91354e-ce50-44d0-a959-fa451bb9cf20"}}}], "length": {"value": 0.0253548, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "7f0e2518-b943-445a-b36b-df23de1add14", "name": "l(r:p1rdt5155lv-p1rlv10540)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85351f49-cb19-4f71-a6ae-a21f5a48af6f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4829cd2f-7e61-4386-89ce-89d77d5ef5cf"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "5e07c049-b3d7-4d1a-9c10-f0144ef0ecfe", "name": "l(r:p1rdt5159lv-p1rlv10544)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba7e3a6b-f62f-432f-afe7-2ebbfc9abd59"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c722b89-fdaf-416f-863e-02b443375ba1"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "082ef98e-736d-4b9d-8761-8e1f28430622", "name": "l(r:p1rdt5172lv-p1rlv10563)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48efdcb9-083c-4e17-a1d2-acb1388f085e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8a10822-398f-441e-a5ca-73303d832183"}}}], "length": {"value": 0.0709049, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "de3f7150-cc4b-4cdd-8586-d90b3e9f0791", "name": "l(r:p1rdt5179lv-p1rlv10573)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd4155b2-ca55-41d7-bd35-98a5eec8c39a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94677ede-fd5c-4fbb-bfcd-98cf67b56913"}}}], "length": {"value": 0.0550518, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3957c039-612c-45ec-869b-4310f9d481bb", "name": "l(r:p1rdt5179lv-p1rlv10583)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd4155b2-ca55-41d7-bd35-98a5eec8c39a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0431d17-75da-48c1-965c-875f61b0e9bf"}}}], "length": {"value": 0.0550518, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0997b3ce-c275-4e58-aafb-272b62d6c6b6", "name": "l(r:p1rdt5180lv-p1rlv10576)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae26acb3-c2c9-479c-9d19-c30bf00aa8c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25141e20-0a65-4905-b37f-954ed1a8751c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "e5f30957-f466-42ef-b23f-40321acb3168", "name": "l(r:p1rdt5183lv-p1rlv10582)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bbde2e8-42c0-486b-9759-78898d177f93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdfa726f-5606-4ae2-b358-ad664dd7b0e3"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b6b313aa-24d6-40ba-afd6-6230958c1568", "name": "l(r:p1rdt5184lv-p1rlv10589)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1656cc28-8a5b-40da-887f-25605dd336aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53019a8a-b453-4add-9d2d-e4ab380fce67"}}}], "length": {"value": 0.0161579, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "55582f95-1e69-4d6b-b0db-f4b4992538e3", "name": "l(r:p1rdt5184lv-p1rlv10600)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1656cc28-8a5b-40da-887f-25605dd336aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "feb19590-c5f4-4982-9e99-20599f08cfe7"}}}], "length": {"value": 0.0127667, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "87f828d3-1f6d-403b-852d-3f8e3c7b7b65", "name": "l(r:p1rdt5184lv-p1rlv10621)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1656cc28-8a5b-40da-887f-25605dd336aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "374d5417-b2c4-4d16-9b91-d2f519921fd8"}}}], "length": {"value": 0.0240219, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3b197939-0e9a-4bb2-97a0-2ba01199fb47", "name": "l(r:p1rdt5195lv-p1rlv10615)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf05c1bb-39cc-48b3-a576-18913e0cff13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b175fcb-d1ee-44eb-8f89-826e40c5db1d"}}}], "length": {"value": 0.00593856, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9cd169ad-8154-4e21-addc-d48efa048977", "name": "l(r:p1rdt5195lv-p1rlv10634)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf05c1bb-39cc-48b3-a576-18913e0cff13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3184f056-3b5f-403d-86a0-f9b28d6bb3e3"}}}], "length": {"value": 0.018580700000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d25b1b60-f739-427b-bb68-d15d2a530266", "name": "l(r:p1rdt5200lv-p1rlv10627)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "03e7bfdb-ff8b-4142-95ef-8d848ff5d2db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32406d7d-51f9-4c16-900b-526985e5f62b"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "1695160c-d7a9-4b56-a36a-9bf4c210266e", "name": "l(r:p1rdt5201lv-p1rlv10629)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8162a8c-5339-4f42-bd7a-b6dbc5ff463b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e183b3e8-d995-4f1e-baee-8d9d4add157e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "91226eb3-4986-4099-afcc-ba8a616753bc", "name": "l(r:p1rdt5202lv-p1rlv10630)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "39eaedd7-75b6-449f-8ff6-6e31f6e74504"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d60a935-dc9b-48ea-8ee7-9b682452035e"}}}], "length": {"value": 0.0271144, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4ab0b458-002d-4941-8fb5-8fa003f96669", "name": "l(r:p1rdt5206lv-p1rlv10637)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "599a2995-33d5-4bcc-8cd3-585ea37577cd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9510bd0-2bba-4522-bfbe-20b94ea400b6"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "24998fa4-29c5-43de-8a56-451bf7088b34", "name": "l(r:p1rdt5218lv-p1rlv10663)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c650eda9-132b-4419-a055-ad68037c7772"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8198c1c5-67e0-49b9-b11a-1f266f7f4bcb"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "4f0bce0b-cec8-4270-90da-19caf6b4f966", "name": "l(r:p1rdt5236lv-p1rlv10720)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f252d81-66ee-40a6-bce7-2891e06b39e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3d48c0e-704d-4205-94a2-ee74be7ae350"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "52f0d3a1-455d-4799-a4f4-b36bd83a3789", "name": "l(r:p1rdt5342lv-p1rlv10955)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e01069aa-388b-4362-9d02-a164f173dc20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75dbf8f0-4cb6-49b7-a2a5-f98e9ff4b8df"}}}], "length": {"value": 0.017914800000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8823cd6f-545e-4acd-bd12-eea1e38174b4", "name": "l(r:p1rdt5342lv-p1rlv11048)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e01069aa-388b-4362-9d02-a164f173dc20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a8fc823-6fe8-4a3b-9437-68aa751f5e3b"}}}], "length": {"value": 0.017914800000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d01caf79-b234-437a-9476-0490ec03d12d", "name": "l(r:p1rdt5472lv-p1rlv11380)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34a1276e-c702-4c69-b7b1-566d400da2de"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f949a06a-817e-4666-95bb-9536ce06a694"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b63446ac-e79f-48cf-b564-dee1da12a798", "name": "l(r:p1rdt5475lv-p1rlv11384)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d181674-9355-488b-8a3f-5b7c844c35a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0c23aea-471f-4d10-9500-1bc14a67d7e7"}}}], "length": {"value": 0.0318484, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "07dc8977-0ddc-41bf-98a9-8dfec5f9d3b4", "name": "l(r:p1rdt5475lv-p1rlv11386)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d181674-9355-488b-8a3f-5b7c844c35a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f512d86-c9d9-4f58-9d5a-418d0732dc94"}}}], "length": {"value": 0.008446400000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9d9f36bf-d24f-4ab2-a186-fcf4cf92cb27", "name": "l(r:p1rdt5475lv-p1rlv11397)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d181674-9355-488b-8a3f-5b7c844c35a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fd316b0-fd98-4193-9c1b-aaa7d92a4284"}}}], "length": {"value": 0.0375424, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f8c8391e-0f26-45c6-aa81-d7d2ebd35f26", "name": "l(r:p1rdt5476lv-p1rlv11385)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0888f4c5-e037-4891-99fb-fd43934ffae0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2115e8bb-fe49-49ad-8687-68feca212557"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "54f88b11-22f1-4b51-9851-8a348fa7f66b", "name": "l(r:p1rdt5477lv-p1rlv11387)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fafd64c3-efe5-4684-b06f-44e4c8555aa4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbca8c57-0da4-4368-9821-7a9ca4282173"}}}], "length": {"value": 0.0726843, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4ecd7eab-ac7e-4a24-ac86-8a3f9931e089", "name": "l(r:p1rdt5478lv-p1rlv11388)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5107bc9c-f463-49f6-a92f-23c5730475e2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12377bf0-f258-4c29-ab26-e938c95ee25c"}}}], "length": {"value": 0.0557394, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "38a0fb7e-0479-4716-ad92-ef062f819e5b", "name": "l(r:p1rdt5478lv-p1rlv11398)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5107bc9c-f463-49f6-a92f-23c5730475e2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97aa01fe-2e60-4617-8c89-d36f425087fe"}}}], "length": {"value": 0.0557394, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b3073021-9bde-4166-9c27-e2551b7120aa", "name": "l(r:p1rdm11569-p1rlv11390)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "004f56b2-ec94-4189-91b8-46b4af22faa6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b6420b1-3456-42fc-9266-c2b84e063cec"}}}], "length": {"value": 0.110315, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "de9801d0-ebc2-474b-85f2-d670474b0d18", "name": "l(r:p1rdm11569-p1rdt5480lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44ac9e38-8ae3-4102-822b-1c638a6c878a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "004f56b2-ec94-4189-91b8-46b4af22faa6"}}}], "length": {"value": 0.0194577, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "be1cb5ab-a890-4c9b-8c5d-ca7990b7fa8b", "name": "l(r:p1rdm11570-p1rlv11401)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8be902f6-4cca-4ce5-9f73-a1f96c65d8ef"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a215d7dd-8081-4355-9c38-4fd3d2c859c7"}}}], "length": {"value": 0.0577794, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c8464817-2597-4ffb-9d58-991b40d0d49f", "name": "l(r:p1rdm11570-p1rdt5480lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44ac9e38-8ae3-4102-822b-1c638a6c878a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8be902f6-4cca-4ce5-9f73-a1f96c65d8ef"}}}], "length": {"value": 0.0194641, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "878ec4a9-cef2-42e8-8ff1-768ea4ee08b7", "name": "l(r:p1rdt5481lv-p1rlv11392)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f213ee9e-6ae7-4e82-9f25-6fc456f45576"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e740a352-ac8f-4ae2-ace3-254fccd7f96f"}}}], "length": {"value": 0.00971421, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "27b93701-b086-409f-b6c4-248ad3a79eab", "name": "l(r:p1rdt5481lv-p1rlv11394)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f213ee9e-6ae7-4e82-9f25-6fc456f45576"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "996d3e44-142c-42fa-bf4f-2bd1777122dd"}}}], "length": {"value": 0.00971421, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d927f88c-f87d-4609-b7d9-3b440a8942a8", "name": "l(r:p1rdt5483lv-p1rlv11395)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a73d544-9f33-49d9-b648-c806addf3c06"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29922f55-f36a-4b9e-8836-5f9dadd641b7"}}}], "length": {"value": 0.0408239, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b45fdc13-573f-4d62-8969-6d807aee8b95", "name": "l(r:p1rdt5485lv-p1rlv11399)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40eaefce-482f-4a89-bec1-2c11bac2bfb7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68a9eead-8197-4e82-a444-2a4544ec9ddb"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "400b640e-346e-4663-9421-ff28dce9686e", "name": "l(r:p1rdt5650lv-p1rlv11671)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28a6e44b-c6c7-4556-b4d8-d55359391c66"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "834a5733-5264-4adf-861a-25e494df3e37"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "2f30c2bf-be3e-4b60-a6e7-231231e94831", "name": "l(r:p1rdt5653lv-p1rlv11674)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38d1de19-1f51-4875-acc2-a75e3d1a290e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "45f2a901-e4f7-4055-a3e2-b60c61d5033e"}}}], "length": {"value": 0.0467126, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f1e52a68-1c9c-4651-b590-c66946bb5bd9", "name": "l(r:p1rdt5656lv-p1rlv11677)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "87e8c57e-67ff-439c-b28b-0fbdbfd62ea6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b2f121a-2202-43c0-8684-81913a5d6ea9"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "cd9590d2-b2ef-45a1-a2a0-7879503ae2da", "name": "l(r:p1rdt5662lv-p1rlv11684)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea73a91a-b052-486e-810b-1a5ad281e07b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02aef971-5f4a-4ca8-aa33-cce34517bd44"}}}], "length": {"value": 0.0429078, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0d0ec938-717a-4694-87b7-c4ffcc8becc4", "name": "l(r:p1rdt5663lv-p1rlv11686)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16a67a88-5d11-4eca-85fe-38c948ad362c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cda8e361-98b6-49bd-a3ff-30a036a3dc6f"}}}], "length": {"value": 0.0119369, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e9a6d297-511a-4374-baa4-5957c5a9660a", "name": "l(r:p1rdm11909-p1rlv15645)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5b71ca5-a7ab-42f7-824a-bc43fc1708cc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "449098c3-4f65-4350-863f-4b7bc1f14493"}}}], "length": {"value": 0.043632500000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1ac2f810-c321-44b7-95e4-0c2294035bca", "name": "l(r:p1rdm11909-p1rdt5663lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16a67a88-5d11-4eca-85fe-38c948ad362c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5b71ca5-a7ab-42f7-824a-bc43fc1708cc"}}}], "length": {"value": 0.0154548, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "367b85dd-74f1-4252-bf45-811d7899bfaa", "name": "l(r:p1rdt5728lv-p1rlv11779)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6d456893-4d89-455a-b1a5-4863aad6293a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0ba1408-17da-4678-8b04-90c616c3fb48"}}}], "length": {"value": 0.0661386, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "fadcfd18-1437-4d57-ae07-5feb2b125a65", "name": "l(r:p1rdt5728lv-p1rlv11783)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6d456893-4d89-455a-b1a5-4863aad6293a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3890375-c01d-44d2-93f9-8d9d60da8852"}}}], "length": {"value": 0.0661386, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f3b9d6c3-246a-4d60-9f2a-b29050a691c1", "name": "l(r:p1rdt5729lv-p1rlv11780)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95f81d7a-a6af-4843-bfa1-002abc7ff870"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e9a574d-9537-417a-a811-e22d84b8ea53"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b41f8809-5b99-439f-9bd6-a6fc8cb47c7c", "name": "l(r:p1rdt5730lv-p1rlv11784)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2dd206bc-965d-46c9-8fdb-8c158c7bba05"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b66df0bc-6159-42fa-bf49-b8ad17d0e6aa"}}}], "length": {"value": 0.0506895, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2c42071d-569c-4f35-8d65-90380f97501d", "name": "l(r:p1rdt5730lv-p1rlv11786)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2dd206bc-965d-46c9-8fdb-8c158c7bba05"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b15fc66-89d9-483b-9c9f-9b0f39a63b29"}}}], "length": {"value": 0.024148300000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2b57623a-601b-4dbd-bc38-661889b37a6b", "name": "l(r:p1rdm12071-p1rlv11781)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64ee7f4c-b91a-4a25-b85d-a91b83777c1f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28fd9f7c-0195-4529-a972-aa60eced47d2"}}}], "length": {"value": 0.0191276, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3d9ddc49-14e7-4dd7-a2c5-d98beb0d3444", "name": "l(r:p1rdm12071-p1rdt5730lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2dd206bc-965d-46c9-8fdb-8c158c7bba05"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64ee7f4c-b91a-4a25-b85d-a91b83777c1f"}}}], "length": {"value": 0.0173818, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8b230ec6-5ef9-47a7-990c-fafb6e26a6c3", "name": "l(r:p1rdt5731lv-p1rlv11782)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e414162-eda7-4cf2-9116-fc24af9461bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "496fc854-bbf8-463b-b16c-12dd1b444cc6"}}}], "length": {"value": 0.0292119, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a73dcae4-6fc0-4b6f-a432-3cb5ef33058b", "name": "l(r:p1rdm12075-p1rlv11785)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7103c2f0-8160-434f-b4b3-edfbd7e97464"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ed0eb774-fcc3-417f-a8a4-fbdb825cc106"}}}], "length": {"value": 0.0190573, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d6dbe381-462c-408e-87b7-e82db0872b88", "name": "l(r:p1rdm12075-p1rdt5731lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e414162-eda7-4cf2-9116-fc24af9461bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7103c2f0-8160-434f-b4b3-edfbd7e97464"}}}], "length": {"value": 0.0194685, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "40793b09-be51-4c19-855d-a9cab1a29975", "name": "l(r:p1rdt5840lv-p1rlv12028)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9974869d-7d87-4a27-9606-076cd7799953"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1dfd848-b639-41b5-ad95-2c03a51bd36b"}}}], "length": {"value": 0.0166971, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "59eddbe0-cc88-4acf-aab0-ee9589891212", "name": "l(r:p1rdt5840lv-p1rlv12157)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9974869d-7d87-4a27-9606-076cd7799953"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc4d79bb-8ba3-4146-9d50-16db48ffec22"}}}], "length": {"value": 0.0166971, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "80b0ac16-51ce-4b22-8d60-68d9d40dc483", "name": "l(r:p1rdt5923lv-p1rlv12214)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "751d2f2e-bb6f-4ca6-9e86-0e2b5ff3f92a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df9d9de2-6929-48a4-a390-c0e2f129b374"}}}], "length": {"value": 0.0436747, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "55166bbd-4d92-45f6-90c8-7e525148435b", "name": "l(r:p1rdt5923lv-p1rlv12217)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "751d2f2e-bb6f-4ca6-9e86-0e2b5ff3f92a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4d26673-c304-41de-8b5b-149552601ba4"}}}], "length": {"value": 0.0140011, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8cba7cbc-61c9-40c7-a472-15ba57ed7cc2", "name": "l(r:p1rdt5923lv-p1rlv12222)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "751d2f2e-bb6f-4ca6-9e86-0e2b5ff3f92a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cee79fe8-f140-4be9-aa6b-d56e37fb6857"}}}], "length": {"value": 0.06246270000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d23744d0-51a4-42f6-a714-7ca8bc4f452a", "name": "l(r:p1rdt5923lv-p1rlv12225)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "751d2f2e-bb6f-4ca6-9e86-0e2b5ff3f92a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8e1f797-9417-447c-8a08-cf00a462ef14"}}}], "length": {"value": 0.0351977, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "5163b09b-32f5-4b89-8d37-f90900ee57a4", "name": "l(r:p1rdt6038lv-p1rlv12538)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d654945d-b71d-4943-86a2-5830fca200c9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b42c2471-9114-4042-980e-dd226ad024a3"}}}], "length": {"value": 0.010266900000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "804e6cda-09e4-439b-b278-de2464a271a4", "name": "l(r:p1rdt6043lv-p1rlv12552)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ae7bbf-f53e-4ae2-8145-bf56ce935094"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c42d772-e2a8-45d4-9cf2-2edd7a567b35"}}}], "length": {"value": 0.0181528, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "b31deec8-a68b-4572-a9fa-62a1124c070a", "name": "l(r:p1rdm12875-p1rlv12553)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3e53a11-6c13-4d27-89f2-2abbd28f69ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a29aec49-62a4-41ec-a67c-a84470a23f7b"}}}], "length": {"value": 0.0385577, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "5ee09bf3-d8ba-4f9e-ae22-905ffbba3cfa", "name": "l(r:p1rdm12875-p1rdt6043lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ae7bbf-f53e-4ae2-8145-bf56ce935094"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3e53a11-6c13-4d27-89f2-2abbd28f69ac"}}}], "length": {"value": 0.0560413, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "d6a45977-5d4a-4d99-a466-58bc7bf18e45", "name": "l(r:p1rdm12876-p1rlv12559)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b748c697-b624-43f0-b375-5024d8cff92b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a47101-b6df-473e-9c7b-96e076c17931"}}}], "length": {"value": 0.0120531, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "09aeebd8-f06b-4d31-bf4d-0e7a60792681", "name": "l(r:p1rdm12877-p1rlv12562)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3082eb6b-1a9f-4b6e-930e-f58173fe02ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b0417d3-820d-4daa-aec5-3dcf34e40e00"}}}], "length": {"value": 0.00937768, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "d8bd73cc-9912-47ad-abdb-98e0f3860f40", "name": "l(r:p1rdm12876-p1rdm12877)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b748c697-b624-43f0-b375-5024d8cff92b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3082eb6b-1a9f-4b6e-930e-f58173fe02ac"}}}], "length": {"value": 0.00528266, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "7b24a598-5dca-4ef9-a2fb-eb6cd38fc84c", "name": "l(r:p1rdm12876-p1rdt6043lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ae7bbf-f53e-4ae2-8145-bf56ce935094"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b748c697-b624-43f0-b375-5024d8cff92b"}}}], "length": {"value": 0.0304331, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "388119d6-f740-4a34-b677-297b11d1d4a9", "name": "l(r:p1rdt6046lv-p1rlv12557)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2e2d1a7-039c-4b29-a061-b814ac675e3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fe4d6ae-cca5-476c-981a-a1dcd27b1e84"}}}], "length": {"value": 0.0315499, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "ee6ada67-4f86-4be6-b132-2aad7bf157f5", "name": "l(r:p1rdt6047lv-p1rlv12558)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21e75ccd-7e21-4f0d-890c-81aa6b33b109"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a427f20-861a-4616-9443-265beaeccca3"}}}], "length": {"value": 0.00804165, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "24ad47a8-99be-4c96-9d61-3961533ba7d0", "name": "l(r:p1rdt6208lv-p1rlv12936)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01be483b-09f4-450e-a39d-78692c40ee8b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "019e419c-9f88-455a-bf48-b89531ed9e51"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "3f467e00-f448-4c36-8cb1-d2229235a0d9", "name": "l(r:p1rdt6221lv-p1rlv12959)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73f78740-2ec5-4ad8-b7fb-40f4a72b730e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8418804f-aad5-49df-9916-f427da5089c1"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "fb81f428-e1d6-442c-82a6-cb1c5af44b3c", "name": "l(r:p1rdt6226lv-p1rlv12971)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3154eee7-a1ba-4b9d-9e91-bab55529d358"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be845651-8e1c-4b6d-8633-fcbdfb1fd5d4"}}}], "length": {"value": 0.0550308, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "209ae9db-43f7-4864-9a91-dd599c660b29", "name": "l(r:p1rdt6226lv-p1rlv20185)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3154eee7-a1ba-4b9d-9e91-bab55529d358"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "646058a3-cda7-4723-bd0f-05d305fe7c11"}}}], "length": {"value": 0.0550308, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "baa087fe-f55d-461e-98a8-a7791ca43e18", "name": "l(r:p1rdt6268lv-p1rlv13043)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72ce0706-6b32-4b4b-9bf3-fd1f5a6af5ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3072c6c-3a40-4e49-bd00-febc8268b135"}}}], "length": {"value": 0.038529200000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c319e0c1-2119-4d87-af76-491d2ce8fdec", "name": "l(r:p1rdt6268lv-p1rlv13047)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72ce0706-6b32-4b4b-9bf3-fd1f5a6af5ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4209bdad-276f-4e07-93e0-78b162ce95cf"}}}], "length": {"value": 0.0748394, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "009b3a8c-9e06-4cda-bc24-d2f036ee33a2", "name": "l(r:p1rdt6268lv-p1rlv13054)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72ce0706-6b32-4b4b-9bf3-fd1f5a6af5ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21c6ea4f-ec9d-424e-8743-7175408f9e2c"}}}], "length": {"value": 0.0369069, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a53a4533-5597-4cc6-9369-c1ea467408b4", "name": "l(r:p1rdt6269lv-p1rlv13044)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79c91fa8-15ad-4e8d-96bd-2cad395dd280"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa31c772-8460-4624-a123-64b87ca8d332"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "bc4eed45-5ff4-4307-bb2c-bb2c0189e21a", "name": "l(r:p1rdt6270lv-p1rlv13045)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5adb2083-3d46-48a7-8996-37c0781b0215"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6070414d-09e7-48a7-aec0-c105cc0f1a93"}}}], "length": {"value": 0.034086700000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8b7550b3-6d1b-4305-af43-5cc86d9bf52f", "name": "l(r:p1rdt6270lv-p1rlv13046)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5adb2083-3d46-48a7-8996-37c0781b0215"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5edc15fb-49d5-4052-8fad-4979578f6ed1"}}}], "length": {"value": 0.0160269, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "09abe480-4eaa-43f7-a172-88856f758284"}}}}, {"uuid": "93980ed3-1b22-488f-8670-d1ef74982523", "name": "l(r:p1rdt6270lv-p1rlv13052)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5adb2083-3d46-48a7-8996-37c0781b0215"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86d59550-d7c8-47e1-a6bc-14b2d50de58c"}}}], "length": {"value": 0.04494170000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "786442b2-02c0-49ce-84bc-697eb42f86e0", "name": "l(r:p1rdt6271lv-p1rlv13048)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1335e64c-9f37-4e73-a37f-8f76737cabff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "569078be-37c2-4c05-8455-91945eb7fdb9"}}}], "length": {"value": 0.0901436, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "559c20cc-21df-4271-8c6c-9082c619342d", "name": "l(r:p1rdt6272lv-p1rlv13049)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04422e0a-1952-422d-a201-5fafef1875db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ed85192-4c5a-4c15-ba21-1ba883b03ddd"}}}], "length": {"value": 0.00941805, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f04b5148-7972-4220-8564-2067c13a4eb3", "name": "l(r:p1rdt6272lv-p1rlv13053)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04422e0a-1952-422d-a201-5fafef1875db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e058437-0138-4305-a33e-d8fa61aed8cc"}}}], "length": {"value": 0.00941805, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2f3c609b-2021-408f-8726-e117aee9d249", "name": "l(r:p1rdm13376-p1rlv13051)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b6739c0-1b15-42c1-9fdd-4d7f604a03ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9a855b0-538e-4fab-91f1-93b4ece09409"}}}], "length": {"value": 0.0533824, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1160992a-885e-46ae-b199-876ea6532f62", "name": "l(r:p1rdm13376-p1rdt6274lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1db8c80-e791-4c31-a6f2-713aa665bf41"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b6739c0-1b15-42c1-9fdd-4d7f604a03ce"}}}], "length": {"value": 0.0171039, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f4585475-d917-4176-9105-3c08f98e6ae2", "name": "l(r:p1rdm13377-p1rlv13056)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e395985-4c66-49c9-9252-94d8078b8e8e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16584dfd-537d-4b0d-a651-c73d0beabc6d"}}}], "length": {"value": 0.04504020000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3415f9bf-f574-44ed-b40d-dde7483331f3", "name": "l(r:p1rdm13377-p1rdt6274lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1db8c80-e791-4c31-a6f2-713aa665bf41"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e395985-4c66-49c9-9252-94d8078b8e8e"}}}], "length": {"value": 0.0171039, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7bd303bc-c877-43d3-92ed-7bf8d2e8223a", "name": "l(r:p1rdt6275lv-p1rlv13055)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba567584-fbee-44eb-b3f1-da24a0ce66a0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387df3d3-5f03-47f4-8b16-bea8815e63d1"}}}], "length": {"value": 0.0150884, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ce961dd6-3068-4529-b5b2-7ae148f76be1", "name": "l(r:p1rdt6275lv-p1rlv13058)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba567584-fbee-44eb-b3f1-da24a0ce66a0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c83997dc-872f-494f-8c8a-7266c854fc48"}}}], "length": {"value": 0.0150884, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f7952fba-5181-4715-84ef-6c47236d1571", "name": "l(r:p1rdt6276lv-p1rlv13057)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f20ace2-5ec8-4451-b7e7-66f46c2c487b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c63d163-75bd-4d91-bcfa-229a2e331b1f"}}}], "length": {"value": 0.0435582, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "de4dd982-2e26-43e0-bd9e-d2a4a732efb1", "name": "l(r:p1rdt6276lv-p1rlv13062)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f20ace2-5ec8-4451-b7e7-66f46c2c487b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d2fa164-4c03-4bcd-a386-749ccd4e9001"}}}], "length": {"value": 0.0435582, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "085a1bfb-ff94-46ab-9c2a-9f9baee7d5e7", "name": "l(r:p1rdt6277lv-p1rlv13059)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e582b04d-a8d8-4ee9-8576-1e5941623c0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a1779b5b-1a6c-4511-9d4b-88026b430173"}}}], "length": {"value": 0.00731377, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "87f20977-ad83-4193-8443-34331741b51d", "name": "l(r:p1rdt6278lv-p1rlv13060)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b37eabc-787a-491f-bc4f-956f43a862ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8767a040-da31-48d9-9473-0941856bcedc"}}}], "length": {"value": 0.0214401, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4863f307-9b70-4638-bfb9-09034f350d4b", "name": "l(r:p1rdt6345lv-p1rlv13185)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a38eb6d-a625-42a1-95f6-bbf078d1447a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c29c3206-b71d-41d1-8ad7-a693c8c25d4d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "422ef105-d242-44fb-a517-c36ddd805f83", "name": "l(r:p1rdt6347lv-p1rlv13187)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e40008af-ff50-42bd-8897-f663c27a436f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ffbd17b6-b1a2-4e55-9052-67a84419bb9d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "f4d53aad-8c53-4280-8a58-e354c3deb985", "name": "l(r:p1rdt6348lv-p1rlv13188)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d84ac329-f314-41be-a2ee-89bc74789a18"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67ffcd9f-ba90-4da7-b3b6-46310e321590"}}}], "length": {"value": 0.0371493, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b9f20c71-b16d-49bc-b80b-42f92cd6aded", "name": "l(r:p1rdt6348lv-p1rlv13191)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d84ac329-f314-41be-a2ee-89bc74789a18"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f6d09e9-3592-4560-8626-0d7cb71ca56a"}}}], "length": {"value": 0.0217677, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "99adfcee-ce5d-4d2a-8a1e-e54a38a2c08d", "name": "l(r:p1rdt6348lv-p1rlv13195)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d84ac329-f314-41be-a2ee-89bc74789a18"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e3e10c6-6ce2-4efa-be50-80e8b9bffe29"}}}], "length": {"value": 0.0257734, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3912c661-e4ef-4616-8d05-3299ab44ff9e", "name": "l(r:p1rdt6348lv-p1rlv13201)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d84ac329-f314-41be-a2ee-89bc74789a18"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cdd7c49-e758-4009-8db5-d0b5748f919c"}}}], "length": {"value": 0.008488610000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3c1adb4d-4ff6-4c8a-8c1a-43251f741964", "name": "l(r:p1rdt6349lv-p1rlv13189)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdfa0310-7dc5-4181-a64e-cc2522370547"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "268361f6-d5ac-4002-80a6-f56f3b33599c"}}}], "length": {"value": 0.0123575, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "59797aff-2413-4c30-b02b-f1d86b4483ea", "name": "l(r:p1rdt6350lv-p1rlv13190)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0138b892-d18e-497c-9857-c4d5676deac2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3dbc593c-3949-4fa4-8738-d92540dbf998"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "5cf6510a-4dea-4772-ad91-0ea898f6570e", "name": "l(r:p1rdt6353lv-p1rlv13194)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "015322ae-7712-488f-9569-33fc785e4f62"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d5ba889-d8f7-44ca-86b2-40939fa95df2"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "3c73b898-fe34-4069-b66a-29eddd852722", "name": "l(r:p1rdm13558-p1rlv13196)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fd10fd1-b67f-422c-b976-582e2bb4e0ec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27013147-3d8f-4d75-a7a7-24457dc6d62a"}}}], "length": {"value": 0.0952802, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d43267bf-c60c-46cf-a3c3-40514c8ed391", "name": "l(r:p1rdm13558-p1rdt6354lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f06a08bd-05ea-4914-b0d0-07cd0e83bfbc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fd10fd1-b67f-422c-b976-582e2bb4e0ec"}}}], "length": {"value": 0.019710700000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b6dc79bc-04b3-4a9d-95f9-39133febe09b", "name": "l(r:p1rdm13559-p1rlv13200)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "786efaf4-c281-4def-9a4e-2ffbf37e08be"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fed30a3f-12a5-4545-b5d5-5c13a131a256"}}}], "length": {"value": 0.0781624, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "336fd466-42ce-4a03-a8b1-500c9b6320ff", "name": "l(r:p1rdm13559-p1rdt6354lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f06a08bd-05ea-4914-b0d0-07cd0e83bfbc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "786efaf4-c281-4def-9a4e-2ffbf37e08be"}}}], "length": {"value": 0.0196968, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3fb850f0-48fc-4d93-9b2f-53099e8c7a93", "name": "l(r:p1rdt6355lv-p1rlv13197)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1d14a79-4d18-43fe-8790-57ea9adf83a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b077d0f-74ec-4a04-8eb8-cf02ad16077d"}}}], "length": {"value": 0.00855264, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7445bde4-f85a-4868-beaa-c9eb3c64ae62", "name": "l(r:p1rdt6356lv-p1rlv13199)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "548724aa-110a-428f-b71a-acdf0051dc39"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad7545fb-8a41-4ed7-a178-e90f19bfa9d5"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "1b5cb726-1c52-4df2-8c39-dd309d7acca2", "name": "l(r:p1rdt6409lv-p1rlv13316)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e36cfaaa-3996-4cc6-aa4f-170f20c5d1e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473b080b-1412-40dc-a452-09d43a462098"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "9e896bae-73ca-433f-9ddc-b981c3e73cf1", "name": "l(r:p1rdt6498lv-p1rlv13597)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "353889fb-da44-4cf8-ae0e-d20541f36d7e"}}}], "length": {"value": 0.0114781, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8553403c-d26e-4b50-8608-cd168ebfbd94", "name": "l(r:p1rdt6498lv-p1rlv13631)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6015a810-79da-480f-b1a1-fd6a4abdba37"}}}], "length": {"value": 0.00314293, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "c01c83bb-3dbc-4882-b0f0-e842930869ba", "name": "l(r:p1rdt6498lv-p1rlv13696)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f92273c9-90b8-4819-b036-9d69afb5aed6"}}}], "length": {"value": 0.0270935, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1b049af0-8fb0-40ee-8c70-d2be4bee9165", "name": "l(r:p1rdt6498lv-p1rlv13702)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fe3c958-296f-4b51-8b2b-74bb34ddb5a6"}}}], "length": {"value": 0.0161535, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d15500ac-94ef-479c-a786-fdd84b84b87e", "name": "l(r:p1rdt6498lv-p1rlv13703)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9efacf5-5b96-4670-b6f1-dc398485cde9"}}}], "length": {"value": 0.0105519, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4fc94db9-da62-43ee-9583-c2c0fd98625c", "name": "l(r:p1rdt6498lv-p1rlv13724)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "136b29b4-37b7-429e-8069-009aac1ce3d7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "457c6c9d-5020-4cf3-9c1e-c36012a619d2"}}}], "length": {"value": 0.0187626, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8091ae42-7ca0-4232-911a-682fa9fb74a3", "name": "l(r:p1rdm13996-p1rlv13598)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce39f1f5-b784-4919-9d3d-f6149f39595e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59953c2f-244e-4bb8-ab24-b28d82b195e1"}}}], "length": {"value": 0.0312105, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "01e418b1-0c88-4fa1-9b60-1516e6ba9401", "name": "l(r:p1rdm13996-p1rlv13626)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce39f1f5-b784-4919-9d3d-f6149f39595e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aeea20e0-9908-4f28-aa5d-068244e3861b"}}}], "length": {"value": 0.045519500000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "166332aa-67ba-485f-93b1-02469f1cdf58", "name": "l(r:p1rdm13996-p1rlv13635)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce39f1f5-b784-4919-9d3d-f6149f39595e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc33013a-6a90-46a7-9127-f32288111c14"}}}], "length": {"value": 0.0353648, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2b8702e0-0e6b-4594-a41c-501c6a9f441d", "name": "l(r:p1rdm13996-p1rlv20504)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce39f1f5-b784-4919-9d3d-f6149f39595e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b3e7495-7732-42ce-8d53-a5f1b7383ce4"}}}], "length": {"value": 0.0518247, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f092bdfa-1b2e-4449-91e0-4c62efc169e0", "name": "l(r:p1rdm13996-p1rdt6499lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb05d831-1556-4f56-8065-d9d16657caa3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce39f1f5-b784-4919-9d3d-f6149f39595e"}}}], "length": {"value": 0.0125057, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0581c111-e821-458c-a17c-100b3ff33c3a", "name": "l(r:p1rdm13999-p1rlv13698)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f85240e6-bbbe-4b90-8419-a00a3ca9613f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3839c291-3f45-46c3-973f-6a9615fcf81b"}}}], "length": {"value": 0.0426193, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "40b10f22-d50a-4135-8e84-81fa97145e9b", "name": "l(r:p1rdm14000-p1rlv13726)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea740eb8-42c6-4417-97d6-7c73f1fc2bc8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "642597e6-fe60-442f-b356-2be6f21677b2"}}}], "length": {"value": 0.00697416, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "072d74a7-35ce-499b-be52-d6ad80a0dc15", "name": "l(r:p1rdm13999-p1rdm14000)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f85240e6-bbbe-4b90-8419-a00a3ca9613f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea740eb8-42c6-4417-97d6-7c73f1fc2bc8"}}}], "length": {"value": 0.0139057, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5f658b70-1fd2-4e3d-ac5c-c7a295a50529", "name": "l(r:p1rdm13999-p1rdt6499lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb05d831-1556-4f56-8065-d9d16657caa3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f85240e6-bbbe-4b90-8419-a00a3ca9613f"}}}], "length": {"value": 0.0125149, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f76f9ba9-1ad5-411f-8fe0-e19d0b125427", "name": "l(r:p1rdt6500lv-p1rlv13613)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a20a4242-8a76-49f3-9bf5-3d7aaf751cdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "216537dd-ea7b-461c-b821-99491c41b7f0"}}}], "length": {"value": 0.0114283, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "ebf5f920-605f-4b2b-9361-25feec533c82", "name": "l(r:p1rdm14004-p1rlv13618)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83aa4266-e486-4e00-a09b-7bcdc613a9b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f823a90c-effd-489c-9e0a-c110ccb7b9e8"}}}], "length": {"value": 0.0123108, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "c92a290b-f056-49ba-b87b-2d53df6805ed", "name": "l(r:p1rdm14007-p1rlv13653)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff282b99-30bb-4c1d-acb9-02fafe241577"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c61a243-7736-46a0-a950-7cc811381158"}}}], "length": {"value": 0.0534886, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "a96b6494-0b33-4e6a-86cf-59557654a321", "name": "l(r:p1rdm14002-p1rlv13599)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c0ae3b1-ac0d-43c9-9a1e-c73bd10e3ad8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2a60818-4310-4100-9aa8-35ef37aa5f40"}}}], "length": {"value": 0.0432926, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "6d4b04c7-dd70-46da-9bc3-430fe1b50bb9", "name": "l(r:p1rdm14005-p1rlv13648)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d576dffc-af75-488e-8c51-19aa726f0505"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62a29ac5-7227-43b2-b602-b1189cc93839"}}}], "length": {"value": 0.0533671, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "6fe861c6-ef06-4253-98a7-6b8afb1cd014", "name": "l(r:p1rdm14002-p1rdm14005)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c0ae3b1-ac0d-43c9-9a1e-c73bd10e3ad8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d576dffc-af75-488e-8c51-19aa726f0505"}}}], "length": {"value": 0.00732814, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "b3bdf82d-ea8f-474c-92c9-d4b35eb23516", "name": "l(r:p1rdm14002-p1rdm14007)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff282b99-30bb-4c1d-acb9-02fafe241577"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c0ae3b1-ac0d-43c9-9a1e-c73bd10e3ad8"}}}], "length": {"value": 0.007327430000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "f5e00887-072c-477b-a27b-8a1bb5b644a1", "name": "l(r:p1rdm14004-p1rdm14007)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83aa4266-e486-4e00-a09b-7bcdc613a9b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff282b99-30bb-4c1d-acb9-02fafe241577"}}}], "length": {"value": 0.007320720000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "3c9c08f9-58e9-4367-aee8-72788caa6a7c"}}}}, {"uuid": "8653ff7a-8098-4538-800a-42481de0aacb", "name": "l(r:p1rdm14004-p1rdt6500lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a20a4242-8a76-49f3-9bf5-3d7aaf751cdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83aa4266-e486-4e00-a09b-7bcdc613a9b5"}}}], "length": {"value": 0.00898801, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "f731ee6a-9af9-40b1-a1a2-dadc871f741c", "name": "l(r:p1rdm14008-p1rlv13687)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e5abf33-75a2-446f-9c6c-1f3384b78c24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4671f981-e26e-4f26-9698-7f9068ce6dec"}}}], "length": {"value": 0.00688001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "c55b8ce0-a116-435e-81c7-4803d454bdde", "name": "l(r:p1rdm14009-p1rlv13719)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "592b8095-ba99-4993-a445-9af51fa89f57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44aa3f37-e0db-4050-b47f-ac14b7fa6534"}}}], "length": {"value": 0.00707054, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "1bfc33e4-b04b-4983-8901-3644068a4e2f", "name": "l(r:p1rdm14006-p1rlv13652)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33445b16-68bf-4606-8ac5-def4763fb95d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3310c14a-d1ee-4d0c-8428-d002703c61d5"}}}], "length": {"value": 0.00737761, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "55929b77-1dd1-4d96-8f47-b2896190c205", "name": "l(r:p1rdm14006-p1rdm14009)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "592b8095-ba99-4993-a445-9af51fa89f57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33445b16-68bf-4606-8ac5-def4763fb95d"}}}], "length": {"value": 0.00898801, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "195330b0-ed90-4511-a59e-4f29b3f0af24", "name": "l(r:p1rdm14008-p1rdm14009)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e5abf33-75a2-446f-9c6c-1f3384b78c24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "592b8095-ba99-4993-a445-9af51fa89f57"}}}], "length": {"value": 0.00898801, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "876bd333-5a47-4e8f-a9b1-cc4abcb2151a", "name": "l(r:p1rdm14008-p1rdt6500lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a20a4242-8a76-49f3-9bf5-3d7aaf751cdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e5abf33-75a2-446f-9c6c-1f3384b78c24"}}}], "length": {"value": 0.017982000000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "3c9c08f9-58e9-4367-aee8-72788caa6a7c"}}}}, {"uuid": "342ef8ad-e444-494e-ad4c-92901121506a", "name": "l(r:p1rdt6501lv-p1rlv13600)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59ab6d81-a91c-4350-8f94-abe02e3e1555"}}}], "length": {"value": 0.0222413, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "390e5cf1-b1e6-49ab-b980-6194c2f0c071", "name": "l(r:p1rdt6501lv-p1rlv13606)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29838633-5c95-4b73-8227-cfa7f4aedc32"}}}], "length": {"value": 0.0135771, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e9b80295-684b-4497-aeca-3ac73bfe04d1", "name": "l(r:p1rdt6501lv-p1rlv13608)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5e8caf4-4d81-4bbd-98df-6622c5ad0563"}}}], "length": {"value": 0.00679883, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5b4b52a4-31e7-4087-bb1e-24c7c491bf3e", "name": "l(r:p1rdt6501lv-p1rlv13619)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f693a1d2-5499-4810-9458-f205eda265fa"}}}], "length": {"value": 0.0334092, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "97e8fcf2-7304-40bf-ae9b-e7cdd37a4fb7"}}}}, {"uuid": "d453bf68-5c20-462a-8a81-469dded3c831", "name": "l(r:p1rdt6501lv-p1rlv13622)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4540b2cb-ee21-4515-a7ca-fbca371f060d"}}}], "length": {"value": 0.0312591, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c582d791-9861-4686-a34a-1a5ee46f781c", "name": "l(r:p1rdt6501lv-p1rlv13637)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30c470ac-39d1-4379-9ae7-790d912bce2c"}}}], "length": {"value": 0.0185945, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "99295cd8-2b7e-4cca-aa16-0b8d909f4c06", "name": "l(r:p1rdm14016-p1rlv13683)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b7d4c6f-98b5-4cec-b8a4-9311b5fc92bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "de45dc59-3e0a-4b33-8cf4-d5213b0140c1"}}}], "length": {"value": 0.0352211, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ca89eb81-8901-400a-9265-f885565a3423", "name": "l(r:p1rdm14016-p1rdt6501lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33aae0d8-f149-49b3-bf0e-27ecc0cea923"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b7d4c6f-98b5-4cec-b8a4-9311b5fc92bd"}}}], "length": {"value": 0.0288269, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2db45833-0f3f-4f0f-837b-c37add7fd184", "name": "l(r:p1rdt6502lv-p1rlv13601)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7682e9f7-1272-4781-b128-34c7329afe49"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91953a27-bbc7-494a-bec2-a12b4c0f6af6"}}}], "length": {"value": 0.015644, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7c0d2bec-f934-477c-9124-d3536213c299", "name": "l(r:p1rdt6502lv-p1rlv13634)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7682e9f7-1272-4781-b128-34c7329afe49"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "987b05d5-9bb9-434d-98b3-623ee5014870"}}}], "length": {"value": 0.015644, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c18dbc35-bff3-4eed-8032-7a9d865d9cb8", "name": "l(r:p1rdt6505lv-p1rlv13604)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387e7785-8d40-4ddd-8c2b-14a83d4e7401"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9b83bdf-b564-4997-bfc7-1be2f2e58199"}}}], "length": {"value": 0.0220113, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "316eb2e4-da26-4004-9bc7-4f0f810b0c35", "name": "l(r:p1rdt6505lv-p1rlv13605)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387e7785-8d40-4ddd-8c2b-14a83d4e7401"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c39dc6f1-08b5-4bc1-a6ae-be0076af56aa"}}}], "length": {"value": 0.021993400000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c4d7cf80-30b7-49d5-bc93-a33daa9a50b4", "name": "l(r:p1rdt6505lv-p1rlv13654)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387e7785-8d40-4ddd-8c2b-14a83d4e7401"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7be734c-88e2-42c1-8061-f4632bd05759"}}}], "length": {"value": 0.0264068, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2fa21c7c-b71e-481c-8ba0-705b20e1dd84", "name": "l(r:p1rdt6505lv-p1rlv13676)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387e7785-8d40-4ddd-8c2b-14a83d4e7401"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8df1a69e-5b18-4eef-ab60-543a97257297"}}}], "length": {"value": 0.028008200000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4c9980ea-c901-4e92-bb89-6f907b3a5dca", "name": "l(r:p1rdt6505lv-p1rlv13715)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "387e7785-8d40-4ddd-8c2b-14a83d4e7401"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a822fdb0-b531-49b0-89da-b517e5ae6e3a"}}}], "length": {"value": 0.00829409, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6c069c68-5c44-4ed0-b1cf-af99663412ef", "name": "l(r:p1rdt6507lv-p1rlv13610)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5844baa-5e0f-4edd-9122-fe4255adad0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17d92377-b4f1-4194-89cd-130bddb9b77c"}}}], "length": {"value": 0.0581195, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "89882ab7-3fbe-4a43-8813-4000db50953d", "name": "l(r:p1rdm14031-p1rlv13712)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a2f5fad-c0a9-4f62-a318-ef00c0d4f470"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ab8bce-7c02-4c7b-962e-3fb44a3ab7a9"}}}], "length": {"value": 0.0677651, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8f8439ca-eff8-40f9-aa8d-d359f0721d26", "name": "l(r:p1rdm14031-p1rdt6507lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5844baa-5e0f-4edd-9122-fe4255adad0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a2f5fad-c0a9-4f62-a318-ef00c0d4f470"}}}], "length": {"value": 0.0164067, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "efd01f17-490e-47c7-8d2e-568a421cec6a", "name": "l(r:p1rdt6508lv-p1rlv13611)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "630b2a63-622f-4f78-8390-77c69ba7e393"}}}], "length": {"value": 0.00515213, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5a1a2657-849d-4e13-8c0c-965a8a7ab30e", "name": "l(r:p1rdt6508lv-p1rlv13666)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5868c24b-2a58-459b-8650-a6072241aca8"}}}], "length": {"value": 0.006682040000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c45a4782-6379-4df5-896d-ba72b47ee680", "name": "l(r:p1rdt6508lv-p1rlv13685)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f777bc74-e6f3-4e80-bb72-0764964db21e"}}}], "length": {"value": 0.04116050000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "485ec2d2-baf3-4031-b775-f3a35c51e1f2", "name": "l(r:p1rdt6508lv-p1rlv13701)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa7a324e-d367-49a5-820a-b18e72243265"}}}], "length": {"value": 0.00980837, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "63ca6e20-b870-4ea1-aaea-7904c242ba8a", "name": "l(r:p1rdt6508lv-p1rlv13707)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "286623b3-af08-4a60-896a-1f5b85fe04a5"}}}], "length": {"value": 0.0432014, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4a2c57de-4589-43cc-8447-5abb34d130a0", "name": "l(r:p1rdm14033-p1rlv13651)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "572123ef-d255-42a9-9c61-95d99aaff775"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c808261e-a49e-4954-bdc4-a8b63d0ee25b"}}}], "length": {"value": 0.0148948, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d9124535-9f55-4e17-90ec-cf5341d9c500", "name": "l(r:p1rdm14033-p1rlv13728)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "572123ef-d255-42a9-9c61-95d99aaff775"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9657a993-0005-4ffc-8c9f-18e80a491070"}}}], "length": {"value": 0.00972322, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cc27c9f6-9b6e-4814-b9c7-7166cc2d1bed", "name": "l(r:p1rdm14033-p1rdt6508lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58eb51e9-5232-4c01-bb63-eac0424474e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "572123ef-d255-42a9-9c61-95d99aaff775"}}}], "length": {"value": 0.0189224, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3162f10d-4158-469a-96cd-a51fa01fb20a", "name": "l(r:p1rdt6509lv-p1rlv13612)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f817a28f-c650-4eb4-84c0-751fe5053c75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6eda3e97-a618-41ab-ae55-ba67f6bb0234"}}}], "length": {"value": 0.00552959, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9d01a910-b603-4852-9d53-708297ee103a", "name": "l(r:p1rdt6509lv-p1rlv13628)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f817a28f-c650-4eb4-84c0-751fe5053c75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e47df44a-79f1-423b-a295-c9c354795895"}}}], "length": {"value": 0.0122449, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "516a46a4-a886-40b9-b1ea-e684b208f509", "name": "l(r:p1rdm14041-p1rlv13627)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b65a5fd-f38e-447a-a51a-e7a214ba6bcc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bd69c55-2141-4c8e-becf-efa4bff8a63e"}}}], "length": {"value": 0.0158712, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8cb36820-73d5-492e-8845-b9ec92e8fa18", "name": "l(r:p1rdm14041-p1rlv13659)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b65a5fd-f38e-447a-a51a-e7a214ba6bcc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "122e0772-7de6-4117-b1d3-caafbbbc8e22"}}}], "length": {"value": 0.009054330000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d8df7836-4789-448b-894e-7c1c617c95d9", "name": "l(r:p1rdm14041-p1rlv13660)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b65a5fd-f38e-447a-a51a-e7a214ba6bcc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3d6fd13-2f04-4f23-97a3-cdf99159174c"}}}], "length": {"value": 0.0113115, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "068f969c-0c98-4e0f-9524-1a21a3b8987d", "name": "l(r:p1rdm14041-p1rlv13677)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b65a5fd-f38e-447a-a51a-e7a214ba6bcc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9aa7e62-8974-4ef0-aa5a-bcd545245aea"}}}], "length": {"value": 0.0329272, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "65146649-1d08-42cb-af6c-acc8a012a05e", "name": "l(r:p1rdm14040-p1rlv13624)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1252c522-5ced-4f4c-908c-f58501ad6f92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a5746d1-24a6-4ae4-b5dc-cef23b56660d"}}}], "length": {"value": 0.00954632, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3ae44c1c-f5ef-4516-a648-5583d34cf7a6", "name": "l(r:p1rdm14040-p1rlv13721)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1252c522-5ced-4f4c-908c-f58501ad6f92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6097c903-70fc-4635-a66c-fee2243ba545"}}}], "length": {"value": 0.012462500000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "20173122-d8a7-4c92-a3b7-8ddb76680383", "name": "l(r:p1rdm14040-p1rdm14041)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b65a5fd-f38e-447a-a51a-e7a214ba6bcc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1252c522-5ced-4f4c-908c-f58501ad6f92"}}}], "length": {"value": 0.0125149, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "80fdbbc2-08c7-494f-bc26-6b81701d774b", "name": "l(r:p1rdm14041-p1rdt6509lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f817a28f-c650-4eb4-84c0-751fe5053c75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b65a5fd-f38e-447a-a51a-e7a214ba6bcc"}}}], "length": {"value": 0.0139057, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "52d0c8fb-a66f-4033-93f4-79e9ae946d79"}}}}, {"uuid": "c8f1e6a0-c36c-4ce6-99e7-ee182b295e7f", "name": "l(r:p1rdm14043-p1rlv13633)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9be8942c-8459-4c1d-a3b0-a89ee5cced4e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b3fe33f-fdcf-42f5-be08-8da15a4d4958"}}}], "length": {"value": 0.036068300000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "95e07a95-448b-4b98-80fa-457bcde4ecc4", "name": "l(r:p1rdm14043-p1rlv13663)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9be8942c-8459-4c1d-a3b0-a89ee5cced4e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54887ca7-ae23-42d0-a715-aed8baa38ade"}}}], "length": {"value": 0.0442205, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "17a54982-d8e3-4917-97dd-8e7dbe136d17", "name": "l(r:p1rdm14043-p1rlv13672)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9be8942c-8459-4c1d-a3b0-a89ee5cced4e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32bec8ad-b312-4502-a2a1-6a4c9b2dd87a"}}}], "length": {"value": 0.00371517, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "3e5beb3a-4808-431b-a276-401a1bc26c44", "name": "l(r:p1rdm14043-p1rlv13686)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9be8942c-8459-4c1d-a3b0-a89ee5cced4e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60fe0a16-aa4d-4fe8-9f39-81bfa13b505f"}}}], "length": {"value": 0.0111527, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9accb5a7-67c9-4b12-89a4-03446ebd99ee", "name": "l(r:p1rdm14043-p1rdt6509lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f817a28f-c650-4eb4-84c0-751fe5053c75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9be8942c-8459-4c1d-a3b0-a89ee5cced4e"}}}], "length": {"value": 0.0139057, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ca70462c-125c-4416-a604-f000d21623d6", "name": "l(r:p1rdt6510lv-p1rlv13614)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d62fe3b-7644-46d1-8a15-e86d95ae8b2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3de8b994-01ba-4eae-b9cf-7fb174d32355"}}}], "length": {"value": 0.01924, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bb7235ed-bd23-4bb0-99ce-00d534f6ceba", "name": "l(r:p1rdt6510lv-p1rlv13680)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d62fe3b-7644-46d1-8a15-e86d95ae8b2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85b910cd-def8-41d8-ad47-3c074a54ad8d"}}}], "length": {"value": 0.012694, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "52d0c8fb-a66f-4033-93f4-79e9ae946d79"}}}}, {"uuid": "84cbab40-20ee-4d00-86b9-42817ede7a15", "name": "l(r:p1rdt6510lv-p1rlv20467)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d62fe3b-7644-46d1-8a15-e86d95ae8b2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58e2b774-ac04-435e-9e03-573b3aa94cfb"}}}], "length": {"value": 0.00748899, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ff0d00c0-ac17-4823-ada8-ba030479f1ce", "name": "l(r:p1rdt6512lv-p1rlv13616)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "850d5b69-14cf-4a18-8cb0-4f1b3033b0aa"}}}], "length": {"value": 0.0125419, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2ab15224-388d-4616-8bd6-5a213b6945ec", "name": "l(r:p1rdt6512lv-p1rlv13643)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20009de0-cbe7-4b4f-a046-425a6ae71925"}}}], "length": {"value": 0.0106471, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9af93afe-5223-45fd-a014-1b40d134690d", "name": "l(r:p1rdt6512lv-p1rlv13646)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fe0466e-cce5-4c6c-b13f-cedd349b6944"}}}], "length": {"value": 0.00566202, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "023df541-8d16-46bf-b4d4-675baa72fc8a", "name": "l(r:p1rdt6512lv-p1rlv13650)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fa2041e-34c4-4f1f-a329-74969c3da75f"}}}], "length": {"value": 0.0342408, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "13f8ad6d-758e-44f8-8220-06aef0a4c41b", "name": "l(r:p1rdt6512lv-p1rlv13725)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e290046b-c936-4f51-b4ef-632bf572ab7f"}}}], "length": {"value": 0.0322281, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4947106f-8e2e-4805-b3b7-5e9672aadeac", "name": "l(r:p1rdm14062-p1rlv13664)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3ed4387-9ecb-43c4-a392-e72bc5cb32b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70cf02cc-8f1b-48ab-b9e6-50c3e58ad9ae"}}}], "length": {"value": 0.0332206, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "fe342819-1380-4393-a27d-ccc1439cd615", "name": "l(r:p1rdm14062-p1rlv13681)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3ed4387-9ecb-43c4-a392-e72bc5cb32b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60f08cde-51d3-4b51-9ab5-b61c8043950f"}}}], "length": {"value": 0.00918014, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "96b443e2-11df-4e89-981c-41c80cf02023", "name": "l(r:p1rdm14062-p1rlv13717)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3ed4387-9ecb-43c4-a392-e72bc5cb32b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdbfe616-f51f-416a-94ce-6e676d300226"}}}], "length": {"value": 0.00916206, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "488c4454-9ad4-484f-8d9c-aca4b7f2fd67", "name": "l(r:p1rdm14062-p1rlv20509)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3ed4387-9ecb-43c4-a392-e72bc5cb32b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fe37b51-0258-4812-9d96-3cc28c4bd55b"}}}], "length": {"value": 0.00548688, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "022d323e-07da-4138-8e8b-44b035820841", "name": "l(r:p1rdm14062-p1rdt6512lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3ed4387-9ecb-43c4-a392-e72bc5cb32b6"}}}], "length": {"value": 0.018909400000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e3150130-99fc-424b-93c8-da14b313e743", "name": "l(r:p1rdm14063-p1rlv13671)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "485928ba-ff70-4be2-89ff-721ff82269fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2f95b8b-190c-4df2-9dd2-daee5efde34b"}}}], "length": {"value": 0.0398564, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b6d97809-156e-4113-af17-e0200a96fbff", "name": "l(r:p1rdm14063-p1rlv13714)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "485928ba-ff70-4be2-89ff-721ff82269fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17936036-1191-4f91-bc12-2298db7b77e3"}}}], "length": {"value": 0.0397956, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e0a8749f-fc99-4c40-843a-c950cd6b3617", "name": "l(r:p1rdm14063-p1rdt6512lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5702c88a-92e4-40ce-8a51-684fe6662789"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "485928ba-ff70-4be2-89ff-721ff82269fb"}}}], "length": {"value": 0.0189224, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "033e3f67-3877-4ae0-b6ec-ed4ac02d0081", "name": "l(r:p1rdt6514lv-p1rlv13623)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad6bef77-8f39-43b4-b2d7-58aa6e45a60b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80f60ab3-722f-4765-8b91-4fd0196171d7"}}}], "length": {"value": 0.0879332, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4c3fb8e9-1d83-4791-8274-8e68fb1645a7", "name": "l(r:p1rdt6514lv-p1rlv13716)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad6bef77-8f39-43b4-b2d7-58aa6e45a60b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb3b4207-12ad-46e6-b4de-59149a46f8a1"}}}], "length": {"value": 0.107138, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b4624fcd-3303-45b7-aeab-e8182705ea7d", "name": "l(r:p1rdm14072-p1rlv13640)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "395dac73-8fae-4718-a28c-191a76a298f2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "653bdc0d-5b21-4640-861b-b88ddb5c651a"}}}], "length": {"value": 0.0819367, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c040ef88-e64c-4303-83fd-b18d037139ca", "name": "l(r:p1rdm14072-p1rdt6514lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad6bef77-8f39-43b4-b2d7-58aa6e45a60b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "395dac73-8fae-4718-a28c-191a76a298f2"}}}], "length": {"value": 0.0139057, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "caa8dcf0-ff72-42e0-b35b-3d850862220e", "name": "l(r:p1rdt6515lv-p1rlv13625)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b92f8bcd-91ce-42bd-be69-0b43cb9d4122"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c667408-52a0-4258-8e93-557c94520a1e"}}}], "length": {"value": 0.09092920000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "61b204a7-5100-4427-bab6-d2a4ff8ae7df", "name": "l(r:p1rdt6515lv-p1rlv19156)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b92f8bcd-91ce-42bd-be69-0b43cb9d4122"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7538ab85-10b4-4f60-98f8-179e954173b0"}}}], "length": {"value": 0.091396, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "c8be5034-7901-4e58-97e7-41c162aba1d0", "name": "l(r:p1rdt6515lv-p1rlv19163)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b92f8bcd-91ce-42bd-be69-0b43cb9d4122"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fed6fcd4-3c97-4f62-a1a7-0b66394218e1"}}}], "length": {"value": 0.0956659, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "6e8f9e3f-5286-4b5c-b948-13135572f5cc", "name": "l(r:p1rdt6515lv-p1rlv19165)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b92f8bcd-91ce-42bd-be69-0b43cb9d4122"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ebd10471-ab4c-4cb7-a822-a83ef20e9854"}}}], "length": {"value": 0.104528, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "188e1e24-abff-4778-add9-5cd6da283c9a", "name": "l(r:p1rdm14075-p1rlv13645)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2659bd3-f6ca-4d74-87c8-f92596986cb5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1acad56e-b6d6-4fa7-a925-f242c1558eef"}}}], "length": {"value": 0.0654705, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "3f25d6c2-6bb8-45d7-aefd-259a75c39fa3", "name": "l(r:p1rdm14075-p1rdt6515lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b92f8bcd-91ce-42bd-be69-0b43cb9d4122"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2659bd3-f6ca-4d74-87c8-f92596986cb5"}}}], "length": {"value": 0.00777706, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "7d73691e-3ace-4804-a2fc-b1e7bb2fc029", "name": "l(r:p1rdt6516lv-p1rlv13629)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "119a8559-8e6c-4314-9bbd-37ef3adde415"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b4358536-b06f-486d-b336-3a8576b428d0"}}}], "length": {"value": 0.0117712, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a9dc2406-fd4a-460a-b563-9f3869e7a46e", "name": "l(r:p1rdt6516lv-p1rlv13638)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "119a8559-8e6c-4314-9bbd-37ef3adde415"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db3908f7-94f5-43a7-a3de-1f6c9b72ebd4"}}}], "length": {"value": 0.009298230000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c42d401a-12f5-41aa-8978-0bab6fef0238", "name": "l(r:p1rdt6516lv-p1rlv13692)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "119a8559-8e6c-4314-9bbd-37ef3adde415"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "091b545a-eb31-4bea-a0a6-5aa9c7a8397f"}}}], "length": {"value": 0.022541900000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9ce6b824-e446-47d8-9b7f-8e6925a36c68", "name": "l(r:p1rdt6516lv-p1rlv13708)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "119a8559-8e6c-4314-9bbd-37ef3adde415"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a230534-6927-4af8-ba54-6ab4c9c32d21"}}}], "length": {"value": 0.020454, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "082fc58b-a217-4336-9a0d-065c229b7951", "name": "l(r:p1rdt6517lv-p1rlv13630)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5783bae9-2c74-473f-bf18-db40bc975409"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f474e4ba-6300-4014-afe9-c245e08cf3c5"}}}], "length": {"value": 0.0228311, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3c1f055c-199b-4923-bf89-d99e150d0252", "name": "l(r:p1rdm14084-p1rlv13641)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "822f96e6-61c5-455d-8a53-a494b49c9237"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eb10938-4b73-406c-bed4-0bd01e0bc20d"}}}], "length": {"value": 0.0127698, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "dfb21f10-33c3-41a3-a751-c1d7711c1c4f", "name": "l(r:p1rdm14084-p1rdt6517lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5783bae9-2c74-473f-bf18-db40bc975409"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "822f96e6-61c5-455d-8a53-a494b49c9237"}}}], "length": {"value": 0.0159549, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b10d847c-d604-4ede-9f26-ef7617eb21ce", "name": "l(r:p1rdt6518lv-p1rlv13647)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b16b03-1922-4aeb-8e70-d0e1387fbcab"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8753d37-07f1-45c6-a483-43cbfb6bf107"}}}], "length": {"value": 0.025624100000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "16c1caa6-a0ac-4132-a871-c1d589aa9772", "name": "l(r:p1rdm14085-p1rlv13632)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c597db56-a6af-472d-a7a2-e331175a2aae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b712121-d0c2-488a-9224-bea72928796f"}}}], "length": {"value": 0.028921, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "37be34c8-1e2b-49f9-8cb3-aa295a059daa", "name": "l(r:p1rdm14085-p1rdt6518lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b16b03-1922-4aeb-8e70-d0e1387fbcab"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c597db56-a6af-472d-a7a2-e331175a2aae"}}}], "length": {"value": 0.0331741, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "344cfb2a-35cd-4e8b-869a-9b28c99943fd", "name": "l(r:p1rdm14087-p1rlv20154)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180c5680-acd1-4988-ac36-1f351c3f9418"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02f2e50e-d42d-47d1-9274-d840042b64d1"}}}], "length": {"value": 0.0527706, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7ae66157-15aa-48f6-87af-00e3416e452b", "name": "l(r:p1rdm14087-p1rlv20161)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180c5680-acd1-4988-ac36-1f351c3f9418"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11a125b8-023c-4748-98a9-d74e9e0a7d23"}}}], "length": {"value": 0.04340720000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2f1e15b7-c811-40be-81ac-e05c3e936d83", "name": "l(r:p1rdm14087-p1rdt6518lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b16b03-1922-4aeb-8e70-d0e1387fbcab"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180c5680-acd1-4988-ac36-1f351c3f9418"}}}], "length": {"value": 0.0198942, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "228f74d1-87c0-4843-809b-e393c84a2239", "name": "l(r:p1rdt6519lv-p1rlv13636)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "606673ea-bcd2-459a-a0af-efb8b31c600c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4d3fe62-b327-4fc6-b2aa-795c9475019a"}}}], "length": {"value": 0.052177, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "167607d2-178f-4e8d-82c4-9bfd9975fab7", "name": "l(r:p1rdm14090-p1rlv13678)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e06b069-62f8-40c8-9abc-d4cc83937e41"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32b75c61-4e97-4e21-a786-8aab7a2d88f8"}}}], "length": {"value": 0.0759194, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "11760911-163e-44ae-af9b-fbbdf0f687b8", "name": "l(r:p1rdm14090-p1rdt6519lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "606673ea-bcd2-459a-a0af-efb8b31c600c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e06b069-62f8-40c8-9abc-d4cc83937e41"}}}], "length": {"value": 0.00898801, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "259929c5-0a19-4150-9cea-ff8dc5a0a7bd", "name": "l(r:p1rdt6520lv-p1rlv13639)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13c02cd3-cff3-4988-95b9-3993b9541427"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5484eab0-53a8-471c-92ec-29c11c08e740"}}}], "length": {"value": 0.0157099, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b03c2024-3c7a-4d2e-8e6e-7d42de59c0a2", "name": "l(r:p1rdt6520lv-p1rlv13669)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13c02cd3-cff3-4988-95b9-3993b9541427"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "607d3b54-2cea-476b-afe2-ea40c6c02ddc"}}}], "length": {"value": 0.00818072, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a2c154da-c79e-4d92-abad-f78947b543a8", "name": "l(r:p1rdm14092-p1rlv13662)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db3abe20-2ffb-4bf8-b425-5613701bd3f2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e55b944-ffad-47bf-8348-799afa4c7a1d"}}}], "length": {"value": 0.0117517, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2509fb4d-0dfc-4537-aac7-0cd0a6a4c808", "name": "l(r:p1rdm14096-p1rlv13679)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0c27b40-83a9-4938-bc12-a2ae57d5eafb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "284bbc5d-bb49-404d-823e-08ec543c90b8"}}}], "length": {"value": 0.0111879, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ad959039-7919-4664-bbfa-b8fc3bb04d8b", "name": "l(r:p1rdm14097-p1rlv13705)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb3a7829-4233-4af9-9679-08bd114bc00e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f409299-5ac0-4f31-a217-d0aef7fbc4d2"}}}], "length": {"value": 0.006644980000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f0c5ad2b-ab0c-47ff-996f-359b98a541c0", "name": "l(r:p1rdm14096-p1rdm14097)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0c27b40-83a9-4938-bc12-a2ae57d5eafb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb3a7829-4233-4af9-9679-08bd114bc00e"}}}], "length": {"value": 0.0158664, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "612c5150-f8fd-4503-afd5-72b168f3a3c8", "name": "l(r:p1rdm14092-p1rdm14096)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db3abe20-2ffb-4bf8-b425-5613701bd3f2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0c27b40-83a9-4938-bc12-a2ae57d5eafb"}}}], "length": {"value": 0.011940100000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "48f450bb-ff89-4556-9044-213f13d84df0", "name": "l(r:p1rdm14092-p1rdt6520lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13c02cd3-cff3-4988-95b9-3993b9541427"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db3abe20-2ffb-4bf8-b425-5613701bd3f2"}}}], "length": {"value": 0.0119317, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "2d347746-0969-4a8a-b986-c40ef4f4c015"}}}}, {"uuid": "83174978-498d-4a0c-9123-99b6f97be3f9", "name": "l(r:p1rdm14094-p1rlv13673)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a990c6c-4227-4896-8ea6-e92ce5360087"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9467d2d3-ad80-4bc7-aa9f-cd6e76494552"}}}], "length": {"value": 0.0209007, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d8400413-4b6f-448c-8b9f-35fd9343fb78", "name": "l(r:p1rdm14094-p1rlv13675)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a990c6c-4227-4896-8ea6-e92ce5360087"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c532e298-bdd5-416e-8ebe-a082489ffee6"}}}], "length": {"value": 0.023550600000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "47cee057-d034-469d-844a-fc4156ee7c4e", "name": "l(r:p1rdm14094-p1rdt6520lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13c02cd3-cff3-4988-95b9-3993b9541427"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a990c6c-4227-4896-8ea6-e92ce5360087"}}}], "length": {"value": 0.0125632, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fa38627e-ef06-43f8-96ec-98da2f37c21e", "name": "l(r:p1rdt6521lv-p1rlv13670)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0e4e42c-8dcd-47be-bfe8-b8b1eb4a5f24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce53d307-fc73-487a-8f6a-3a0e0787bf79"}}}], "length": {"value": 0.106379, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e0336142-b978-433d-8847-480a4107f3f4", "name": "l(r:p1rdt6521lv-p1rlv13694)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0e4e42c-8dcd-47be-bfe8-b8b1eb4a5f24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1de2ebf2-3207-4bf7-9702-4c729d99a6cf"}}}], "length": {"value": 0.07348910000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d686aa67-4e56-444b-b892-d06c1d8df229", "name": "l(r:p1rdt6521lv-p1rlv13695)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0e4e42c-8dcd-47be-bfe8-b8b1eb4a5f24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d73963d7-acf4-48b3-8e54-6ee9f403d36f"}}}], "length": {"value": 0.0966562, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ac3a550d-5246-49d8-ab21-eaaf8dd0a54a", "name": "l(r:p1rdm14098-p1rlv13642)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c12be3d4-719e-4567-91d9-c0ff24b783f1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "479d1486-ed05-44fa-8fab-64035623f267"}}}], "length": {"value": 0.0796353, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a1ad23ef-8d9b-43dd-9d37-af210c9edc45", "name": "l(r:p1rdm14098-p1rdt6521lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0e4e42c-8dcd-47be-bfe8-b8b1eb4a5f24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c12be3d4-719e-4567-91d9-c0ff24b783f1"}}}], "length": {"value": 0.0189224, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0e50b778-8db4-4046-9cbf-af628dd42567", "name": "l(r:p1rdm14100-p1rlv13682)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1db9a47a-f0ed-4141-b08e-f01a2ffd804f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a3c050c-cc0d-460e-af02-ce3421431474"}}}], "length": {"value": 0.0988767, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "26c24a09-ea79-4de4-86a7-17356670bdac", "name": "l(r:p1rdm14100-p1rdt6521lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0e4e42c-8dcd-47be-bfe8-b8b1eb4a5f24"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1db9a47a-f0ed-4141-b08e-f01a2ffd804f"}}}], "length": {"value": 0.0189224, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fff836a7-3b7a-4332-8fa2-4ccc5047b40b", "name": "l(r:p1rdt6523lv-p1rlv13649)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66df2481-ae4f-4f39-aef4-7af09ce1a8fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43867e2f-79ee-4cec-bed3-0cad0727118c"}}}], "length": {"value": 0.053244900000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c912605f-1e8e-4af3-bc5a-fbd35d1f82bc", "name": "l(r:p1rdm14107-p1rlv13656)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2844042b-3f65-4a8b-8bab-56b42971e6ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8c0a04e-6e22-4da5-9907-7ae8097deb10"}}}], "length": {"value": 0.0192208, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "76751362-f6a1-47cf-a480-da419e869b1d", "name": "l(r:p1rdm14107-p1rlv13690)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2844042b-3f65-4a8b-8bab-56b42971e6ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "71c26ca3-0d61-46b8-a95b-710e0b760b62"}}}], "length": {"value": 0.0119597, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "8c4f49b2-3881-4901-9e2a-bdfedd44bb67", "name": "l(r:p1rdm14107-p1rdt6524lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ec2137a-f978-4808-a023-21f13464998b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2844042b-3f65-4a8b-8bab-56b42971e6ad"}}}], "length": {"value": 0.00891043, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "3f4222b7-7671-4abc-b6ee-713366959169", "name": "l(r:p1rdm14109-p1rlv13700)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2256f06d-59e9-4822-987f-7d26f40415c0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ecf9ee9-2a3c-431b-84c8-02c7c7aaacb1"}}}], "length": {"value": 0.0052345, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "b11a686c-caa0-43bc-9fc6-0c2a668d3c33", "name": "l(r:p1rdm14109-p1rdt6524lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ec2137a-f978-4808-a023-21f13464998b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2256f06d-59e9-4822-987f-7d26f40415c0"}}}], "length": {"value": 0.00891207, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "dac869e3-d445-4ffc-84be-6aab918f7e32", "name": "l(r:p1rdt6527lv-p1rlv13661)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8905812-7e3b-4875-87b5-da95999c5bb0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ef8e6ec-86d3-429c-89b4-6c7260701e70"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "2b6940c8-d947-4c87-a551-5c24bf4ffeb9", "name": "l(r:p1rdt6528lv-p1rlv13667)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d097d9be-dd3a-4616-a873-8ab5013c4e72"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d6cdd514-204d-4a86-b0f3-a9bc4990a2aa"}}}], "length": {"value": 0.0382292, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "3c9c08f9-58e9-4367-aee8-72788caa6a7c"}}}}, {"uuid": "c6f600b4-98d6-4e13-a8d6-9dc0d58ae55a", "name": "l(r:p1rdt6528lv-p1rlv13691)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d097d9be-dd3a-4616-a873-8ab5013c4e72"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "850df31b-ee95-4903-93b7-6e5911e8f8a0"}}}], "length": {"value": 0.0619169, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "feff346b-96b0-43c5-ae5a-f9eddc172f07", "name": "l(r:p1rdm14115-p1rlv13689)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b51fe8ae-f6d7-48c7-9f84-22fc7c1c1ba9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e5db11f-0418-4119-9c71-26619456fd7b"}}}], "length": {"value": 0.0409354, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "3c183149-1fd7-4707-9de8-d0a10af6da6f", "name": "l(r:p1rdm14115-p1rdt6528lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d097d9be-dd3a-4616-a873-8ab5013c4e72"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b51fe8ae-f6d7-48c7-9f84-22fc7c1c1ba9"}}}], "length": {"value": 0.00777706, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "67b7cc4c-7757-4d4e-8d9f-66ce36da8415", "name": "l(r:p1rdt6530lv-p1rlv13684)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4ee2d3a-e97c-4ec4-9fa0-d7db1b3e9253"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ec49353-14d1-4917-83bc-ca62cd94bf30"}}}], "length": {"value": 0.0531129, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8e8b88c6-aab7-4e5c-b8b9-c3c64a663429", "name": "l(r:p1rdt6531lv-p1rlv13693)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf4a2da0-682a-4119-b398-feaa6f5a8498"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5815b75-1226-4221-9bcb-bc75ce85fa17"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "ebaa7012-6c65-4b0d-908b-50ddad06d587", "name": "l(r:p1rdm14120-p1rlv13706)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75c95c35-ea3f-4958-9512-606f78de92b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e60fc98a-9c1d-4975-a9b9-e37271b4ac81"}}}], "length": {"value": 0.0324151, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "3c9c08f9-58e9-4367-aee8-72788caa6a7c"}}}}, {"uuid": "6d45312d-0cad-43fb-9bad-2ce0e6ad3c31", "name": "l(r:p1rdm14120-p1rdt6532lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0c3e71a-52a1-49b9-a899-c13d639ac0a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75c95c35-ea3f-4958-9512-606f78de92b5"}}}], "length": {"value": 0.00967577, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "3c9c08f9-58e9-4367-aee8-72788caa6a7c"}}}}, {"uuid": "e6ce21d6-2d77-4b8d-867a-87e52bca3ba4", "name": "l(r:p1rdm14121-p1rlv19151)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7194199d-e430-4b76-ae77-4c7f51477eed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e396aca-4116-40a0-8f17-bcd41f709ea5"}}}], "length": {"value": 0.0466133, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "9efd1997-d5b4-4e77-8930-a5f5597896ee", "name": "l(r:p1rdm14121-p1rdt6532lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0c3e71a-52a1-49b9-a899-c13d639ac0a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7194199d-e430-4b76-ae77-4c7f51477eed"}}}], "length": {"value": 0.00812092, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "c7be9070-30f3-4700-8c06-470b65f8f19f", "name": "l(r:p1rdt6535lv-p1rlv13711)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10f0e9fa-75b8-4eaa-a2ad-b6a3fb4ae859"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2bfaa34-267c-4dfd-8b6d-4ab444ac4048"}}}], "length": {"value": 0.0759779, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "f13c5842-49ff-4779-bdb6-34cd8e664711", "name": "l(r:p1rdt6536lv-p1rlv13713)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b93e7299-60a4-49d6-9d34-885860588861"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee766a99-bb6f-4d5c-8513-9d462103f6fc"}}}], "length": {"value": 0.00770954, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "858b6e8d-19a5-47af-b192-7fb99a49e5e2", "name": "l(r:p1rdt6536lv-p1rlv13723)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b93e7299-60a4-49d6-9d34-885860588861"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0f1846b-2515-48ef-9241-0276932f8e75"}}}], "length": {"value": 0.00908442, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "43e3456d-a787-4d4e-bad6-2710f05d6c28", "name": "l(r:p1rdm14127-p1rlv20478)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57ac4a24-2ddb-46c2-873d-c0b4f3e0600a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cd0effe0-d186-41a8-8197-24144fbc6218"}}}], "length": {"value": 0.0197863, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "4e91a915-48a9-4e23-8849-e14ae8fa716d", "name": "l(r:p1rdm14127-p1rdt6536lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b93e7299-60a4-49d6-9d34-885860588861"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57ac4a24-2ddb-46c2-873d-c0b4f3e0600a"}}}], "length": {"value": 0.00732814, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "9e793d61-64cc-44ff-b17b-fa7b43a1ec8f", "name": "l(r:p1rdt6539lv-p1rlv13727)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b34f50ff-9a1f-439e-81a8-dfcee658926b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36019623-eb62-412c-a591-41494980c9b7"}}}], "length": {"value": 0.0347798, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "68c65b63-27dd-4e30-9d5e-0bb769ae8388", "name": "l(r:p1rdt6539lv-p1rlv20450)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b34f50ff-9a1f-439e-81a8-dfcee658926b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "006c2753-37b3-4b59-82a6-8ce95f316e26"}}}], "length": {"value": 0.01495, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8b013ff2-c5d6-4080-83aa-2395a67efb7c", "name": "l(r:p1rdm14185-p1rlv13784)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36ab64e0-65cb-4515-9c06-4762a398672a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01a18948-75cf-4caf-951f-17a9c8d1f6bc"}}}], "length": {"value": 0.029367, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4c5e3312-2084-435a-bade-59ec2dae5db0", "name": "l(r:p1rdm14185-p1rdt6574lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a43920a-a200-40fe-b5b6-3cdba0c7e784"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36ab64e0-65cb-4515-9c06-4762a398672a"}}}], "length": {"value": 0.0286402, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2ecb58ca-d359-49c0-802f-611cc5587743", "name": "l(r:p1rdm14186-p1rlv13812)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f2b4d47-9668-4bcc-933b-1f422f423e3e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ffd737b-a273-4a6c-91c6-351b5719f658"}}}], "length": {"value": 0.011645100000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c1340aaa-b2e7-423c-a24c-4984fc6527d5", "name": "l(r:p1rdm14186-p1rdt6574lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a43920a-a200-40fe-b5b6-3cdba0c7e784"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f2b4d47-9668-4bcc-933b-1f422f423e3e"}}}], "length": {"value": 0.0169575, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "88709a42-68a3-404c-a28c-0c84626b3f70", "name": "l(r:p1rdt6581lv-p1rlv13797)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "608e485b-13ce-493b-be96-ab83ad733c92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65052833-aec9-4363-a0cf-4d70fa9bb0ce"}}}], "length": {"value": 0.0873919, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7a451c89-27b1-4961-b1d0-940b9033cd52", "name": "l(r:p1rdt6581lv-p1rlv13811)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "608e485b-13ce-493b-be96-ab83ad733c92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aef2ef8-706c-4316-be01-0707ddf0ac7c"}}}], "length": {"value": 0.06100800000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "93cc41fd-d6c5-4fe6-ae2e-4ba53376e452", "name": "l(r:p1rdm14205-p1rlv13792)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8b7c677-d0bf-47d0-8a2a-78417faa49b9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc5fcb56-435a-4a0d-b442-7489a98ad1cd"}}}], "length": {"value": 0.0873214, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ba97f8d3-dd14-4104-a0f9-e265a224b585", "name": "l(r:p1rdm14205-p1rlv13794)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8b7c677-d0bf-47d0-8a2a-78417faa49b9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9725b6c-5bac-456a-bb6a-ce16a5e6b1a5"}}}], "length": {"value": 0.0656609, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ac827c47-9381-4673-914b-eb251a3782c1", "name": "l(r:p1rdm14205-p1rlv13805)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8b7c677-d0bf-47d0-8a2a-78417faa49b9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83d60921-a1f2-4b9c-9709-d2be59b82db5"}}}], "length": {"value": 0.10165500000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "374da000-183c-490f-b8e4-90a747756774", "name": "l(r:p1rdm14205-p1rdt6581lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "608e485b-13ce-493b-be96-ab83ad733c92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8b7c677-d0bf-47d0-8a2a-78417faa49b9"}}}], "length": {"value": 0.0195453, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9b2db3aa-d79e-4506-8730-e7ec07f13f78", "name": "l(r:p1rdm14210-p1rlv19691)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "487eef02-df2d-47fe-a20b-ce1c23064495"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "604cb559-0f18-4ef7-8bcd-a07a7e7f96d7"}}}], "length": {"value": 0.0580592, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9845e9a8-a0e8-4ac8-b23f-43c8a5ec35c0", "name": "l(r:p1rdm14210-p1rdt6581lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "608e485b-13ce-493b-be96-ab83ad733c92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "487eef02-df2d-47fe-a20b-ce1c23064495"}}}], "length": {"value": 0.0390906, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c0b95dfe-dbb0-4b9d-aea3-888bbaae0e4d", "name": "l(r:p1rdt6847lv-p1rlv14434)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7b9897e-b820-424c-adf8-7416de585357"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06135bd7-6a77-4f04-a439-4ce8c245447d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "17c6ca6d-e99b-4b1e-b84a-cfdad5216da5", "name": "l(r:p1rdt6848lv-p1rlv14435)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94c9fa37-fc5c-4243-b0ca-f70840febaee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d07f5065-df41-484d-8e8a-80b2ff4e0e9b"}}}], "length": {"value": 0.012328000000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ed6ec446-d1e2-423b-95f6-3a2124d16714", "name": "l(r:p1rdt6848lv-p1rlv14436)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94c9fa37-fc5c-4243-b0ca-f70840febaee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad66e41a-88ab-443e-b10e-9e7b5b899119"}}}], "length": {"value": 0.012328000000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fab1734a-805a-45b3-bb29-8ec6cc98ff61", "name": "l(r:p1rdt6995lv-p1rlv14828)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09a476ff-48a0-4d27-9cf0-c007e2e98acb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9efa4c9-9832-4aa8-bf44-be0fe1e80cd5"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b55a7233-970e-4b46-bded-059f90e68dc0", "name": "l(r:p1rdt7015lv-p1rlv14908)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "536d7c56-85a6-4167-b4f6-2f39936cd662"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d73b0321-e181-4ecd-b431-9aa6985d56d0"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "72e2c700-4f3a-43a7-acef-5408f66d50aa", "name": "l(r:p1rdt7036lv-p1rlv14952)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a371c8b-1993-432c-b2c6-21b18bec27da"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3c39b0c-9c92-4934-876f-ee5f542f95cc"}}}], "length": {"value": 0.0147598, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d89a8c28-6964-4a2f-886e-cc984f5a7748", "name": "l(r:p1rdm15468-p1rlv15008)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "260ea1f0-7235-47fc-a576-3d647618290e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19231152-1fd1-4e07-a5d9-603c765b2cae"}}}], "length": {"value": 0.028564100000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b8d33ec2-8be0-4cba-8ff9-a32946eebaf4", "name": "l(r:p1rdm15468-p1rdt7036lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a371c8b-1993-432c-b2c6-21b18bec27da"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "260ea1f0-7235-47fc-a576-3d647618290e"}}}], "length": {"value": 0.0178658, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "97dfa04d-243a-4a4e-83a9-a041fdabcedc", "name": "l(r:p1rdt7038lv-p1rlv14954)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "046f6c53-8d9c-43a1-88ce-169ade9e9557"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9e128f5-eb18-44df-8ec4-35bd049ef630"}}}], "length": {"value": 0.00867639, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e3736839-7824-4b4e-aa1d-9cfd6a158fad", "name": "l(r:p1rdt7046lv-p1rlv14974)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cd6a9808-9889-4f16-825d-c9763357c293"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "884ff47e-8e20-4ae8-97bd-287d0ca9dc1b"}}}], "length": {"value": 0.010648, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "47d4754c-c9fb-4def-99b6-c75a6071c19d", "name": "l(r:p1rdt7054lv-p1rlv14992)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf93e681-3ab6-4929-95f1-1da6d5dd28fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4f8b1bc-83c3-4819-9d98-9491df98d494"}}}], "length": {"value": 0.0136862, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "212f4598-9e6d-4b92-a3d1-44610b4910f8", "name": "l(r:p1rdt7054lv-p1rlv15056)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf93e681-3ab6-4929-95f1-1da6d5dd28fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a914ec3a-4883-42a7-b25d-133a1410b8d9"}}}], "length": {"value": 0.0326989, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e190be67-e711-4051-bfd1-1e315ff72cb0", "name": "l(r:p1rdm15533-p1rlv15046)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25a6c92d-ea7f-4ede-af16-713ceedfc7b0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2182c9fd-fd3d-4cb1-b525-192480823e2f"}}}], "length": {"value": 0.0227649, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "37ac8bba-efa1-4bbc-bda6-22e4836756ce", "name": "l(r:p1rdm15533-p1rdt7054lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf93e681-3ab6-4929-95f1-1da6d5dd28fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25a6c92d-ea7f-4ede-af16-713ceedfc7b0"}}}], "length": {"value": 0.0107297, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2a79d577-2b03-4ef6-84e6-afb335adaea1", "name": "l(r:p1rdt7061lv-p1rlv15007)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc33ade7-4471-40b8-8e9b-1846e0ad60e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc29de5b-3a3f-40c0-bde4-9a57f5f62b5c"}}}], "length": {"value": 0.0316282, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "353ebd25-352a-4d04-9ead-4c6d9ddf80fc", "name": "l(r:p1rdm15583-p1rlv15027)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4445ca5-2fed-4352-ab78-66e072a4f482"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07e3b847-cc9a-4f84-bc00-cb4396b6dea0"}}}], "length": {"value": 0.0140589, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2559653c-404f-472f-89ab-b0aa2c33fe36", "name": "l(r:p1rdm15583-p1rdt7067lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ff878e1-3143-4f8e-aa92-74d0a9046417"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4445ca5-2fed-4352-ab78-66e072a4f482"}}}], "length": {"value": 0.06079190000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "257d6011-c8ae-4eed-b4c4-a349d68240c2", "name": "l(r:p1rdm15584-p1rlv15197)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ad4c131-0be7-46e5-8a32-5ff92552dfe6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80a74c6f-c9ec-4742-8fce-ad73c0a6c459"}}}], "length": {"value": 0.0228694, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d7e0b635-9e9d-4d19-b7fe-d028520488c2", "name": "l(r:p1rdm15584-p1rdt7067lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ff878e1-3143-4f8e-aa92-74d0a9046417"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ad4c131-0be7-46e5-8a32-5ff92552dfe6"}}}], "length": {"value": 0.0279022, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b6c37323-999f-4652-8438-a4e92ddec55f", "name": "l(r:p1rdt7069lv-p1rlv15045)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a1566f1-7f0d-41d7-adad-425c9a344eb0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "baccbdab-efc0-487d-b00d-38d3d4be57b4"}}}], "length": {"value": 0.08356350000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f4a62cdd-7ebe-4533-9ebe-30b2bc677c77", "name": "l(r:p1rdt7070lv-p1rlv15064)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "844bdc22-2e32-43ee-8e0b-26f3f4c107b8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "366c9c98-59f1-46d5-b39c-4046703e5e4b"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "a5acdfb1-a2f0-43f1-87c9-737ff5f1e24f", "name": "l(r:p1rdt7075lv-p1rlv15082)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e0577c2-8275-4303-ad11-2c4f56df3f5c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a56b9ad8-c53b-4652-bf94-a7a7dfb8b306"}}}], "length": {"value": 0.00723071, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "72eeb4f8-eec2-4e80-be4c-3ff5014734e2", "name": "l(r:p1rdt7080lv-p1rlv15109)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d86bd7f-7759-4d74-9c74-d58010498f92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "161d4e7b-30f2-447c-a369-1bfa3ba2cd70"}}}], "length": {"value": 0.0109809, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6dce47af-355e-492c-8ada-a69635288723", "name": "l(r:p1rdt7080lv-p1rlv15125)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d86bd7f-7759-4d74-9c74-d58010498f92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb6d8f13-f04e-4b80-a8dc-e16af1dc860e"}}}], "length": {"value": 0.0299076, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8cdd54a6-9f8d-4ee6-87ab-ae1b4d397431", "name": "l(r:p1rdt7087lv-p1rlv15163)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d0c96fe-78c2-4303-ac5c-bbe440f19666"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdee6d84-9253-4fba-b713-3e41d706e999"}}}], "length": {"value": 0.0407888, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "44e14507-623a-45b0-be7a-6186032730df", "name": "l(r:p1rdt7088lv-p1rlv15170)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f1652e8-6cf7-43d4-8474-e61a74873675"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d2f8fcb-c279-49d5-88be-39e6a1d1990b"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "d401fdd0-f323-47cf-9b6e-243c4816d543", "name": "l(r:p1rdt7089lv-p1rlv15171)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73cfcce9-a925-4f29-9cde-6dd6f50735e1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc7cd505-823c-49bb-9e49-3681267dbef0"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "6e104f67-822c-4dfe-821e-3d2270eaf935", "name": "l(r:p1rdt7090lv-p1rlv15180)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d6a4c80-d261-4350-8224-8fe5191459c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e218b01d-f713-4baf-9688-7e77ea413c8c"}}}], "length": {"value": 0.0031637000000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b937d1b0-3310-4bcf-9eec-ea96efd2c7d7", "name": "l(r:p1rdt7201lv-p1rlv15394)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6718b871-3967-4c29-83e5-441799c7fb92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd21ae8b-7841-43b4-871f-316c4b8b4cd2"}}}], "length": {"value": 0.0100846, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5875340a-352d-4b74-98dc-8883439cd675", "name": "l(r:p1rdt7201lv-p1rlv15399)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6718b871-3967-4c29-83e5-441799c7fb92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ec1f313-f341-498c-b1c2-6669b1cbc629"}}}], "length": {"value": 0.042765000000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "af21b504-5bae-4a97-84c8-ae9d4024e5de", "name": "l(r:p1rdt7201lv-p1rlv15419)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6718b871-3967-4c29-83e5-441799c7fb92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8bc46399-0276-4ae7-aa8b-4cdd3d3555e8"}}}], "length": {"value": 0.018884, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7be73f4f-717a-4cc3-883f-c8f78b45e694", "name": "l(r:p1rdt7201lv-p1rlv15478)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6718b871-3967-4c29-83e5-441799c7fb92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "335df4da-50d2-4fbe-a271-ac04257d35c7"}}}], "length": {"value": 0.031123500000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c680c5e9-2427-48d6-b643-b718a5387491", "name": "l(r:p1rdt7201lv-p1rlv15523)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6718b871-3967-4c29-83e5-441799c7fb92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37ccfa64-1373-49b2-85f6-279abea3c945"}}}], "length": {"value": 0.0693229, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ff3b35e7-9cbd-4064-b36f-4258d2d5cc0d", "name": "l(r:p1rdt7220lv-p1rlv15418)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d5e45d6-867a-4442-8258-2c04891dbc4b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9ca373a-b1c3-464d-bbe3-c05b728beb30"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "53336b97-0132-489e-86d2-5eec0f08b652", "name": "l(r:p1rdt7224lv-p1rlv15487)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d6a6156f-e72a-41f0-a307-e6030de24fde"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "921f8f54-ff83-4d2f-8bf4-ee80bab64ce8"}}}], "length": {"value": 0.0279743, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "907ce719-e56e-447c-b64f-d358a020f2fe", "name": "l(r:p1rdm15891-p1rlv15423)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79c5341b-3cd2-41a3-8bbf-e50857b00dae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26009a7e-9bfc-4967-af28-4d8937539eb1"}}}], "length": {"value": 0.027741000000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "393d7862-5b0a-4473-8ea7-c88cb9850068", "name": "l(r:p1rdm15891-p1rlv15474)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79c5341b-3cd2-41a3-8bbf-e50857b00dae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34e0ffc2-da17-441b-bd4d-26d5a1104712"}}}], "length": {"value": 0.0128476, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c8ea9ba6-341b-45bd-b369-354bb85e916f", "name": "l(r:p1rdm15891-p1rdt7224lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d6a6156f-e72a-41f0-a307-e6030de24fde"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79c5341b-3cd2-41a3-8bbf-e50857b00dae"}}}], "length": {"value": 0.0173084, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c4bc4441-c550-4b03-b0a0-efd60aadab66", "name": "l(r:p1rdt7248lv-p1rlv15466)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2087cee5-9f6e-4400-8ca8-bbb120cd4dae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "544be417-0db6-45a7-8314-ec40944781fa"}}}], "length": {"value": 0.00486903, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "15f7249a-14e6-4e3e-b936-42cf2e976a8b", "name": "l(r:p1rdt7248lv-p1rlv15483)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2087cee5-9f6e-4400-8ca8-bbb120cd4dae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c4e3eac-0b1a-4feb-b39f-079c6d2c1d82"}}}], "length": {"value": 0.0134294, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "04240cde-fe5e-4ae9-98d1-50fa051dd3c0", "name": "l(r:p1rdt7248lv-p1rlv15488)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2087cee5-9f6e-4400-8ca8-bbb120cd4dae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6579cc93-2b08-4010-816d-3bef509000cd"}}}], "length": {"value": 0.0434873, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2566c35a-0bf0-403c-be22-cd9edfb06e03", "name": "l(r:p1rdt7248lv-p1rlv15542)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2087cee5-9f6e-4400-8ca8-bbb120cd4dae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b09822b3-a220-48ff-ad4f-62fca602f8b6"}}}], "length": {"value": 0.0301654, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ee4e3654-f1a1-4d89-8f99-33119ceee479", "name": "l(r:p1rdt7253lv-p1rlv15484)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b4f7df4-5453-459d-8599-48fd5f29a9c6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6749066f-4739-41ec-8369-8da49dd9e1c8"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "42542b12-3e8e-4532-8026-92a216e7df40", "name": "l(r:p1rdt7268lv-p1rlv15525)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1130272e-b98e-496f-aeb9-c094cf9cd824"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6eec860d-08cf-4690-93e6-d909429d363d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "34b56bb4-acd5-442f-98dd-ae6a6000c99a", "name": "l(r:p1rdt7298lv-p1rlv15603)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d304e5e0-2cc1-4167-9fad-6fc72228d828"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "688da57a-6f10-4ef8-8763-202a88c3a495"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b91e6094-8b96-4b15-affe-53e4ab5b4c33", "name": "l(r:p1rdt7301lv-p1rlv15606)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43df4c14-a198-4d51-87f4-80000198cd47"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c32ce070-e690-4fc1-92ac-f857691de578"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "03539cf6-cfd1-4610-938a-815b5e0a0d89", "name": "l(r:p1rdt7302lv-p1rlv15607)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e2a141f-436a-45c0-9c15-179301a439c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32291502-d7be-4b45-8af7-cb217448e73f"}}}], "length": {"value": 0.0250222, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5e2c78d8-d1ca-458b-b93a-19d040944540", "name": "l(r:p1rdt7302lv-p1rlv15638)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e2a141f-436a-45c0-9c15-179301a439c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2715a637-d6f0-4e7b-b43e-20836bf4e614"}}}], "length": {"value": 0.0170411, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "114bfef7-5a42-4ad7-9635-b2c6241c80ff", "name": "l(r:p1rdt7306lv-p1rlv15614)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0926064a-1c87-450a-b282-23708de8aec4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ab2d6dc-f5bb-4320-86f3-bf08bb7cf93f"}}}], "length": {"value": 0.0921771, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "78f8538c-a644-4746-acd7-376a89bed97f", "name": "l(r:p1rdt7307lv-p1rlv15617)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ce9dd2c-9e17-46b7-a6f4-e85077664432"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6106bbe7-7a47-4c50-8b2a-d46d7432bccf"}}}], "length": {"value": 0.0103904, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "001dcfc9-4762-41f3-a424-9dcf9b505aca", "name": "l(r:p1rdt7307lv-p1rlv19146)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ce9dd2c-9e17-46b7-a6f4-e85077664432"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0bb184ad-cb26-4317-8c40-f2c8a9f80dab"}}}], "length": {"value": 0.0154412, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "653186ed-25f7-4a39-a24e-19bebabe5ff2", "name": "l(r:p1rdt7307lv-p1rlv19147)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ce9dd2c-9e17-46b7-a6f4-e85077664432"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "546433b3-d70e-49ed-9037-ec88adda79b9"}}}], "length": {"value": 0.0170949, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9cd99dc2-42f9-42a3-a539-3e46d435271c", "name": "l(r:p1rdt7311lv-p1rlv15622)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2d6046b-9ece-4295-a180-41bf2ce47ce6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1151b559-3ae0-4863-9363-9b395bbfc403"}}}], "length": {"value": 0.0755258, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "851d4bfa-61f2-4b83-92e2-03d2d1598df4", "name": "l(r:p1rdt7314lv-p1rlv15629)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97844fdb-b016-4ca3-8777-b0553ead9297"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec0bca53-a58b-4004-8dba-8defca9db4c7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "22a94b20-8087-46c1-8f36-29081323b267", "name": "l(r:p1rdt7318lv-p1rlv15634)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22b1ecce-d5df-4f42-abb2-9f4c3d3a28c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5af6dae-d20f-4a31-9544-b9455cd639bd"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "2c8762b9-a727-48e6-8626-8b0691e21672", "name": "l(r:p1rdt7550lv-p1rlv16114)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58be5cbe-5a7c-4fa5-972d-e03100b3bb46"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5984e209-9f0e-4844-91e6-902c8329f13c"}}}], "length": {"value": 0.010568, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "eb9dc53f-9107-4f64-8499-6dcf08b592a2", "name": "l(r:p1rdt7550lv-p1rlv16178)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58be5cbe-5a7c-4fa5-972d-e03100b3bb46"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "807b0bef-0d34-44a9-a2a9-0c0a11f4ea8e"}}}], "length": {"value": 0.010568, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7c32c8d6-dd37-4fda-9b4f-cefafc028e7d", "name": "l(r:p1rdt7551lv-p1rlv16115)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c4d7ee3-fc5d-4a17-a717-3d6b6d5a67ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52d1b79d-5c6b-4b44-9998-600c6debd999"}}}], "length": {"value": 0.0259188, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3b54588d-c6e8-4042-a694-8f87967ab8fa", "name": "l(r:p1rdt7551lv-p1rlv16157)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c4d7ee3-fc5d-4a17-a717-3d6b6d5a67ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6efff4f7-c67b-4cfb-a72d-30b6616825b1"}}}], "length": {"value": 0.0259188, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b929915f-3f5c-4a02-a605-4d4873b39119", "name": "l(r:p1rdt7552lv-p1rlv16116)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f5d6708-cef4-4aac-9fa0-c738953c788f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "972f8088-b67b-47d0-a86f-49179dfb1c92"}}}], "length": {"value": 0.0159262, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c71cbb71-235a-44d4-b728-c68916a4acd2", "name": "l(r:p1rdt7552lv-p1rlv16197)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f5d6708-cef4-4aac-9fa0-c738953c788f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "92a37082-36d4-4eca-95e4-88dbcacd6db5"}}}], "length": {"value": 0.0159262, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ec088b7a-ade2-41ea-864c-57e6fd14b91d", "name": "l(r:p1rdt7553lv-p1rlv16117)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7a672b2-d127-4fb5-8cc4-8115b8ef3f60"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "204899ec-81e4-4a72-bf70-69b3428a49a1"}}}], "length": {"value": 0.0305725, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a08734c0-f8c0-4514-bd5a-0a14ae6698f8", "name": "l(r:p1rdt7554lv-p1rlv16118)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86a6d184-d883-4e27-aee5-b89c82163284"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bca0b3a0-d4cb-4a4a-9b14-aa23d9e5e5fe"}}}], "length": {"value": 0.0431821, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "104b928d-0e37-4538-86e0-e3ce3f7cc27b", "name": "l(r:p1rdt7554lv-p1rlv16139)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86a6d184-d883-4e27-aee5-b89c82163284"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c840cf3f-be15-448b-8c03-8942c586b135"}}}], "length": {"value": 0.0529135, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "abbad3a6-93e2-42c7-a931-18251d488605", "name": "l(r:p1rdt7554lv-p1rlv16201)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86a6d184-d883-4e27-aee5-b89c82163284"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68aa5cc5-f6bf-4417-8653-747c56b37b5e"}}}], "length": {"value": 0.0637427, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f7fbf2cc-e76a-457d-ae93-ed19e5ec96f4", "name": "l(r:p1rdt7554lv-p1rlv16209)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86a6d184-d883-4e27-aee5-b89c82163284"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf413742-18c8-483d-b8f1-f125f95323da"}}}], "length": {"value": 0.0332888, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "da4e7bb9-ac02-48a7-8773-f803a9aa7a98", "name": "l(r:p1rdt7555lv-p1rlv16119)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0de9c581-b78b-44d6-8693-59b995e2a3bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0d6e608-d5bf-40d6-9efd-f3b0922e7d77"}}}], "length": {"value": 0.0197555, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "55ec2ab9-796c-472c-8a9d-64fbe049e120", "name": "l(r:p1rdt7559lv-p1rlv16124)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b593ec6-e1e3-48c2-b352-f7966f206aa9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6da4b2d0-66c7-43fb-9aab-3bbac03aa989"}}}], "length": {"value": 0.04179700000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a4d01ff6-e324-423e-8097-8fe2dde83c0c", "name": "l(r:p1rdt7561lv-p1rlv16126)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05e30abd-3c40-4dbd-9261-ca8a8abd9c56"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd41f55a-4b5d-4c19-9787-801072b3b946"}}}], "length": {"value": 0.014319000000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "54c5bc8b-b799-4216-ab3d-e01ebf98fd85", "name": "l(r:p1rdt7561lv-p1rlv16133)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05e30abd-3c40-4dbd-9261-ca8a8abd9c56"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "102b9460-ea9a-4099-b16f-40b8fdf99ef7"}}}], "length": {"value": 0.024141, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "08cb3840-ba64-4648-ac83-a9a0a208e7ba", "name": "l(r:p1rdt7564lv-p1rlv16135)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7588b3b-f54c-483d-b354-b9908483019a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "676de1a3-2dfd-4faa-a057-7739e825d136"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "eb5f1aa9-9ff8-40fd-8116-08d5bd2f5b05", "name": "l(r:p1rdt7570lv-p1rlv16146)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2b3b9e1-3d98-44c1-bd38-9325623a1553"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6d21c357-1033-45e1-84a0-b82ceafe6ab8"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "7d8cd8ac-49ed-4d0d-80aa-a56a0a98e204", "name": "l(r:p1rdt7572lv-p1rlv16149)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69bf048e-54cd-4e41-a23e-485b0cd98fae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b15792ca-a6bd-47e5-8c67-5c3076174848"}}}], "length": {"value": 0.0827433, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f9ca3f6b-08b6-438b-9f86-993d7fa5dd9e", "name": "l(r:p1rdt7572lv-p1rlv16200)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69bf048e-54cd-4e41-a23e-485b0cd98fae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1aacea55-115d-46c3-9590-725cf5040f38"}}}], "length": {"value": 0.0976866, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a44b7dcd-89ab-4bca-aa5d-4fbe0e9b4b31", "name": "l(r:p1rdm16630-p1rlv16158)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33a848c7-076e-4025-863b-ce9151bcc3ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b85e180a-8eb4-4acc-a816-d99758cc16ea"}}}], "length": {"value": 0.0621197, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c4c0ee7e-a839-4490-b368-ac306b9905e2", "name": "l(r:p1rdm16630-p1rdt7572lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69bf048e-54cd-4e41-a23e-485b0cd98fae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33a848c7-076e-4025-863b-ce9151bcc3ac"}}}], "length": {"value": 0.0168609, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ffb75304-be2a-4021-9df7-22035d0c632a", "name": "l(r:p1rdt7574lv-p1rlv16156)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a742708-0f8b-42d0-a977-b5ce5e36a042"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "74edd9e9-24a5-4b36-8ca8-24ef2fa3e972"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "c9189682-4127-4793-8dde-134bd7a7291f", "name": "l(r:p1rdt7576lv-p1rlv16168)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56b05024-7907-458d-a5c3-0e54ffbabdb5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fb5abb7-dd79-49aa-9185-88a90bb45bc7"}}}], "length": {"value": 0.0685246, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4d947146-90b2-45ec-bc1d-69b52e20c50d", "name": "l(r:p1rdt7579lv-p1rlv16177)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d00b7fe-0384-4c12-a0cf-8895458d3b80"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbbe8401-53a1-4ce7-9ce1-02f547055d95"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "e1f41f9d-38bc-4e6e-be1e-8944e4b9739e", "name": "l(r:p1rdt7588lv-p1rlv16206)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abc940b0-c9f5-4582-adaf-ad7f4a79a35f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ca42395-8d67-4e83-80ec-159cacb490f8"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "607adf52-d8db-4ffb-af17-e06b4b4fbc79", "name": "l(r:p1rdt7589lv-p1rlv16210)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53e9cf92-1c91-428f-bdff-64257257ad5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fd05f3c-df77-45bc-8686-458b681a3d08"}}}], "length": {"value": 0.0134298, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a5726d13-5f87-414f-b712-c0bdc1ced439", "name": "l(r:p1rdt7589lv-p1rlv16235)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53e9cf92-1c91-428f-bdff-64257257ad5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56b91b3f-dfdd-41bf-9d2e-a8183077c752"}}}], "length": {"value": 0.0134298, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "83719399-628f-43ed-9d51-afa6375509c4", "name": "l(r:p1rdt7598lv-p1rlv16221)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff1e0d26-d845-43c3-9aaf-01d1c007b9a1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9761003-33fa-482a-967b-b508ab67c19f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "28e30c05-116b-48f0-b762-f119ac7be7c2", "name": "l(r:p1rdt7599lv-p1rlv16222)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d838502-3769-4d70-839b-26fd628ce478"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4809afc1-2d3d-491d-80e5-9cd4e8da08f2"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "5b38ef2e-a672-495a-8c15-b228d75558b7", "name": "l(r:p1rdt7605lv-p1rlv16228)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3488ff0-696f-4180-bc70-41ff37f9c365"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8767650-39c5-4d4a-80ce-af408c246599"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "ec9d0c28-58f8-4219-86b8-4d3fe6dc4315", "name": "l(r:p1rdt7612lv-p1rlv16239)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fdfea70-187a-4bbc-ba3f-69cb74c4d5c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9642fa30-e5f7-42f1-8fda-ab75a265d25a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "ea4ba13f-ec5f-47ae-a475-1ff409bfad77", "name": "l(r:p1rdt7615lv-p1rlv16242)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "269e9ba5-bc54-4cbd-9140-4b1bea74fc53"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e82036d9-e6c8-42c3-b45b-30bef6902bbc"}}}], "length": {"value": 0.0438853, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "66f3614c-b762-431c-bba3-5445c8ac5bc5", "name": "l(r:p1rdt7615lv-p1rlv16261)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "269e9ba5-bc54-4cbd-9140-4b1bea74fc53"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "978533ca-ef57-4cb6-9e7f-b3c6d1bbd7d5"}}}], "length": {"value": 0.0039062, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "65534143-6fae-4784-bacd-558a8b721a34", "name": "l(r:p1rdm16694-p1rlv16253)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65458dd3-50e0-48d3-a0db-0015707d3cea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "268549c6-0c8b-44ac-b933-316b36645366"}}}], "length": {"value": 0.00713936, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "33912f3d-e42a-475f-8eb4-4cf6ed16c0e4", "name": "l(r:p1rdm16694-p1rdt7616lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6af13868-ecb1-4110-be3f-537741287035"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65458dd3-50e0-48d3-a0db-0015707d3cea"}}}], "length": {"value": 0.04559330000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1e096ee0-46cf-48e0-a5c7-6ea777f3864e", "name": "l(r:p1rdm16695-p1rlv16270)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83d31d7a-8900-4f2e-9183-8a10f07e2bdd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c620d4b9-a849-4bf6-b108-118836866602"}}}], "length": {"value": 0.00252406, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "fe55db9e-e385-467e-b205-95aee0e835b4", "name": "l(r:p1rdm16693-p1rlv16243)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "766647d4-7c3c-4058-b30c-dbc593b88ecb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20818cc7-617e-4ab7-8f7c-31eea6496a02"}}}], "length": {"value": 0.00264008, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "80ef82e9-89e1-4cdc-96a2-6fa1ad7525c5", "name": "l(r:p1rdm16693-p1rdm16695)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83d31d7a-8900-4f2e-9183-8a10f07e2bdd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "766647d4-7c3c-4058-b30c-dbc593b88ecb"}}}], "length": {"value": 0.0423278, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "cfe5162e-a033-4a41-818f-eae382c104ad", "name": "l(r:p1rdm16695-p1rdt7616lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6af13868-ecb1-4110-be3f-537741287035"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83d31d7a-8900-4f2e-9183-8a10f07e2bdd"}}}], "length": {"value": 0.0158248, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "2d347746-0969-4a8a-b986-c40ef4f4c015"}}}}, {"uuid": "81f9870b-57d8-46dd-8268-9ddfab130818", "name": "l(r:p1rdt7617lv-p1rlv16244)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4be4af94-fee7-40d6-9061-9a0fe0e7377e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0164339-acc1-4b95-aa31-3af42cf943f7"}}}], "length": {"value": 0.0112872, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "713a3da4-b5d5-4fbf-98a9-8452a1617c74", "name": "l(r:p1rdm16697-p1rlv16255)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d1fb8eb-57aa-4366-afe5-b79174f3a4c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04647fad-19dc-4ed8-8820-aa312674145c"}}}], "length": {"value": 0.0169738, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c2ff74fe-7d8e-4aeb-8e9c-f1f0a2cb7fde", "name": "l(r:p1rdm16697-p1rdt7617lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4be4af94-fee7-40d6-9061-9a0fe0e7377e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d1fb8eb-57aa-4366-afe5-b79174f3a4c7"}}}], "length": {"value": 0.0068104, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bac616b7-1504-4880-87c4-0dbc21ee3814", "name": "l(r:p1rdm16699-p1rlv16252)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "795f4296-7c54-4e96-8468-52903af39708"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5c6a5f39-0654-4e73-8050-c6c4ad9d54e6"}}}], "length": {"value": 0.0353234, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e02a1459-a30a-43eb-9142-957ff82ef685", "name": "l(r:p1rdm16698-p1rlv16245)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acb015a8-a9f8-492b-ab3f-b107bd956f91"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3783c838-b72e-42cd-8b0b-3005bca3cf5e"}}}], "length": {"value": 0.0114502, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "47db165b-0d9a-4146-8789-b79d73c2dd6c", "name": "l(r:p1rdm16698-p1rdm16699)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "795f4296-7c54-4e96-8468-52903af39708"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acb015a8-a9f8-492b-ab3f-b107bd956f91"}}}], "length": {"value": 0.0170042, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ea0f86b2-7d46-447e-afb9-c85eb9d4acac", "name": "l(r:p1rdm16699-p1rdt7618lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49f37435-54fc-42b4-baba-94f0611c8c76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "795f4296-7c54-4e96-8468-52903af39708"}}}], "length": {"value": 0.0170124, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f5a0982c-76ee-4c76-b17b-db2b29132c0a", "name": "l(r:p1rdm16700-p1rlv16267)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73030a97-0574-4802-80d1-14fefeafa63a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19aeb510-ac0e-4279-8db0-8de282beccc8"}}}], "length": {"value": 0.0129138, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ab960f3a-b750-4490-8919-1b78f1ee81f9", "name": "l(r:p1rdm16700-p1rdt7618lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49f37435-54fc-42b4-baba-94f0611c8c76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "73030a97-0574-4802-80d1-14fefeafa63a"}}}], "length": {"value": 0.0510234, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "aef758c3-6056-49d2-8a02-60b50c63bd6e", "name": "l(r:p1rdt7619lv-p1rlv16246)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a205379-48f9-444c-baf8-dc84fc9c6d8a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd2dc2db-787a-4732-bae4-01186082a92d"}}}], "length": {"value": 0.0487659, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1ba0dfcc-9d4f-4d9d-9b25-d4ac783d610a", "name": "l(r:p1rdt7620lv-p1rlv16247)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af91c50-929d-4ac6-9272-7c44d17a0094"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8d5e9b7-dc95-41f9-8547-99d5e2eba874"}}}], "length": {"value": 0.029204400000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9a074422-3751-46be-a791-1c5831090b87", "name": "l(r:p1rdt7621lv-p1rlv16248)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60f0bddf-6e4b-495c-a98d-f3940d69a5e9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "feb24768-feab-40f0-acc3-0b2bb500133a"}}}], "length": {"value": 0.0226951, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8c4067c2-4a24-4294-b0b5-9e078686ce14", "name": "l(r:p1rdt7624lv-p1rlv16256)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e2075fb-9691-447e-9a73-f88649310bc1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32a9302f-2d40-4c2a-bde9-e4039694fed7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "0179bbe7-ed91-420f-bc7e-556355621ed5", "name": "l(r:p1rdt7625lv-p1rlv16257)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6b1e3b6-ce3a-4ad6-a046-6608530b2ec2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "935c99a6-bef6-4417-872c-0685011c440c"}}}], "length": {"value": 0.08197240000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b7d74205-f9f2-4629-b005-d28349a3ee52", "name": "l(r:p1rdt7626lv-p1rlv16260)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56f8eed1-77ae-4d65-80aa-7ae148350333"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdf35585-e2b3-4463-a6a8-acb352f25003"}}}], "length": {"value": 0.0157324, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "faadfdae-2d72-4662-91e7-ec1f7654ef6b", "name": "l(r:p1rdt7626lv-p1rlv16269)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56f8eed1-77ae-4d65-80aa-7ae148350333"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc746539-662a-4fe4-8774-6ba2dc538118"}}}], "length": {"value": 0.00987847, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5edfcfe0-2c44-4832-938e-e09b4621e7c1", "name": "l(r:p1rdt7627lv-p1rlv16262)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90d8891c-6e6d-46b9-8f88-acc9453c6541"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2797febc-f5e7-4cb3-b26f-ace990dc6920"}}}], "length": {"value": 0.00420024, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "18404b85-1ac1-4964-b5a4-69db35c99ef9", "name": "l(r:p1rdt7630lv-p1rlv16266)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ad2599f-313b-49c6-abaa-19177e1a9edc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8835446-b333-4be9-96bd-57ff9d01ebd3"}}}], "length": {"value": 0.0649914, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9c3cc8d2-c149-4fa9-8e26-1cfb3d5840fe", "name": "l(r:p1rdt7631lv-p1rlv16268)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4861056b-b634-4900-94bb-d6c995387351"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba6ebe7f-b6b9-4f89-8bbf-7bffd63e10ef"}}}], "length": {"value": 0.0412806, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "fe7937ea-1d97-4b06-ae00-05043b6f5450", "name": "l(r:p1rdt7699lv-p1rlv16416)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bfa76dc8-4007-4e52-9692-2eec7cb574e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f58421d6-268b-417f-a579-c9c51d010697"}}}], "length": {"value": 0.079141, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e329d231-586c-4da4-be1c-635869501cb7", "name": "l(r:p1rdm16862-p1rlv16395)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e60bfe9e-d2fa-4576-87f3-0a866b88d07d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d908890-4fe4-4349-92de-464c4165b185"}}}], "length": {"value": 0.0592066, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "468c39e1-9b75-4323-be99-3513b80c5ba1", "name": "l(r:p1rdm16862-p1rdt7699lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bfa76dc8-4007-4e52-9692-2eec7cb574e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e60bfe9e-d2fa-4576-87f3-0a866b88d07d"}}}], "length": {"value": 0.0187021, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ca527da2-14ed-422f-b70c-1bc7bd4d4a7e", "name": "l(r:p1rdt7701lv-p1rlv16397)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0cc95d09-c799-488e-81e8-50326a7da1ea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "323373a9-8e7d-4fb4-8970-dcc0e6d26c98"}}}], "length": {"value": 0.0805765, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f9812016-b945-4e02-8acf-7b54729433c8", "name": "l(r:p1rdt7704lv-p1rlv20070)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ef392d6-b408-4a7f-8a67-9fe43e1df582"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "571a4c92-95b6-4bc0-a25d-0d9239a41a89"}}}], "length": {"value": 0.0912722, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "69240808-930b-4994-9d23-dee6955da16c", "name": "l(r:p1rdm16872-p1rlv16401)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0797f1d0-3499-4f88-a749-fc576240f791"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eeb598c2-f0b9-44df-bfaa-be66e4dc3920"}}}], "length": {"value": 0.0257854, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "18b08e77-eb01-4b55-b1ce-98e572b7dd24", "name": "l(r:p1rdm16872-p1rdt7704lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ef392d6-b408-4a7f-8a67-9fe43e1df582"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0797f1d0-3499-4f88-a749-fc576240f791"}}}], "length": {"value": 0.0193937, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7cba66ff-a6ee-4381-9e47-2a5af2de3377", "name": "l(r:p1rdm16873-p1rlv20068)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5e00667-6368-49d3-a5dd-c574c79dba21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0b689f0-d4b1-4419-bff8-f72436625c60"}}}], "length": {"value": 0.0406184, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ba8749a8-823d-4c50-9058-f01580cfa960", "name": "l(r:p1rdm16873-p1rlv20069)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5e00667-6368-49d3-a5dd-c574c79dba21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f0e3c74-2d63-4612-b0e5-d986ebee0086"}}}], "length": {"value": 0.0750315, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9621505b-497f-4f4e-b57f-a04130b6eca0", "name": "l(r:p1rdm16873-p1rdt7704lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ef392d6-b408-4a7f-8a67-9fe43e1df582"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5e00667-6368-49d3-a5dd-c574c79dba21"}}}], "length": {"value": 0.019391500000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e7f8fc5c-5a80-4393-8e10-ac437b20b61d", "name": "l(r:p1rdt7712lv-p1rlv16412)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59a62487-c709-428e-9e97-c7c285a1305c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99f97a6b-4e94-4a35-ad00-12e7004ab5e3"}}}], "length": {"value": 0.0485398, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f0906201-838f-44bd-962b-5a532e582278", "name": "l(r:p1rdt7718lv-p1rlv16422)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6d10a4e-e7bc-4448-bca3-a5f2117b6198"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f367b63c-c4cb-4810-a270-8bd0153b7b32"}}}], "length": {"value": 0.013767300000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6fa6e077-a768-476b-84c5-2aa32a00b492", "name": "l(r:p1rdt7718lv-p1rlv16424)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6d10a4e-e7bc-4448-bca3-a5f2117b6198"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2242f1c-542f-4c1f-b3e6-19482cccde8d"}}}], "length": {"value": 0.013767300000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "067decd6-dc2e-405c-b604-7300ea1905a2", "name": "l(r:p1rdt7735lv-p1rlv16445)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96dcd934-01a0-4719-89bc-a18430edf179"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e090544-3c8e-4716-9dae-0b311a1017ea"}}}], "length": {"value": 0.0284282, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d86ce606-0132-488e-ba44-92843bfb8d12", "name": "l(r:p1rdt7790lv-p1rlv16570)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ed564b5-8d49-4ff7-94c2-b245981472e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53d578d8-8492-471b-8f66-233e489a3652"}}}], "length": {"value": 0.0553998, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7ea5b970-dc67-44e2-af2f-76936ea99183", "name": "l(r:p1rdt7954lv-p1rlv16905)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9dd5bb5-1410-4635-8a85-d23d7c3e55ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7578563f-d4b3-423b-a8f5-3ee91a042d19"}}}], "length": {"value": 0.0850821, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "00df3659-93b5-43ea-a55e-a0893faccc10", "name": "l(r:p1rdm17416-p1rlv16882)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e982887d-97c6-4af5-b536-a15a372b3379"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4faf40b9-9ade-45b5-ade8-3f1833605cd1"}}}], "length": {"value": 0.09884780000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "729ab8bb-81b7-460d-8b0e-e4f5ef25eda6", "name": "l(r:p1rdm17416-p1rdt7954lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9dd5bb5-1410-4635-8a85-d23d7c3e55ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e982887d-97c6-4af5-b536-a15a372b3379"}}}], "length": {"value": 0.0184307, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ef9a2339-09f7-486b-8e23-0b908af565b6", "name": "l(r:p1rdt7973lv-p1rlv16912)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3a96167-4b09-49c9-baf7-4fb588ecb002"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2308dc3-d10b-4049-862d-caf3356fa9a7"}}}], "length": {"value": 0.0637175, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2719d040-2a20-4bbc-bbf1-d5f6272f6310", "name": "l(r:p1rdt7973lv-p1rlv16988)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3a96167-4b09-49c9-baf7-4fb588ecb002"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11a633b0-2b09-4c66-94d4-d1c24cdd9cf5"}}}], "length": {"value": 0.0681669, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7cb3929d-dcf6-4fa6-bf71-8d2d79fbacd7", "name": "l(r:p1rdm17505-p1rlv16904)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53ed549a-9c24-4bdd-9e40-aee5308d8120"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c570ef7-c483-4c1e-b0fd-8712e8e9a7cd"}}}], "length": {"value": 0.0396092, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "792c1524-361f-42ca-81a5-8f88a601bd78", "name": "l(r:p1rdm17505-p1rdt7973lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3a96167-4b09-49c9-baf7-4fb588ecb002"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53ed549a-9c24-4bdd-9e40-aee5308d8120"}}}], "length": {"value": 0.0168466, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1313795b-a5f9-4cc6-a9c8-7943979110f3", "name": "l(r:p1rdt7983lv-p1rlv16919)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb63be48-94ec-4c9f-9991-77892e14171b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07e01053-37f3-4b9f-a9f1-d51bccd29803"}}}], "length": {"value": 0.079259, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "85650fc1-1735-4e05-8f26-86c5ca8437b9", "name": "l(r:p1rdt7983lv-p1rlv17033)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb63be48-94ec-4c9f-9991-77892e14171b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfa28657-cd8e-4700-a189-83e021f77bee"}}}], "length": {"value": 0.0492948, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0f5baa05-57eb-4dcd-b077-ae2d13649e82", "name": "l(r:p1rdt7986lv-p1rlv16922)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "415fe6e9-953e-40f6-8ae8-43834e4e6ce4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce315d98-1556-429b-aebb-0c868892396a"}}}], "length": {"value": 0.0143418, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "001d627b-af02-488f-b9c8-23280b783daa", "name": "l(r:p1rdt7986lv-p1rlv16957)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "415fe6e9-953e-40f6-8ae8-43834e4e6ce4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7dff1455-5154-429f-a33f-044d8501281d"}}}], "length": {"value": 0.0453768, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6476ae7e-8f41-498c-9da2-84e326f9d60a", "name": "l(r:p1rdt7986lv-p1rlv17063)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "415fe6e9-953e-40f6-8ae8-43834e4e6ce4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19130741-0fe1-4a12-8a55-96355609bccb"}}}], "length": {"value": 0.0371136, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e0da39bf-f183-4b18-9021-71a39d01f9bd", "name": "l(r:p1rdt7988lv-p1rlv16926)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94f12107-697c-4278-95e0-32b6eb49fdb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ba1d053-4462-4eb4-aca6-5ede38aa283c"}}}], "length": {"value": 0.00743277, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "150161df-4909-484b-95b0-d6b3d384dbc8", "name": "l(r:p1rdt7988lv-p1rlv17106)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94f12107-697c-4278-95e0-32b6eb49fdb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5439f343-8176-4d92-99d4-bb9209817f6b"}}}], "length": {"value": 0.00743277, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b7fe8781-6590-4253-9abb-c7288b33a95b", "name": "l(r:p1rdt8012lv-p1rlv16992)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5b22c57-7912-4e9f-9b06-6a8ff706a58d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57e8aa34-3967-4f22-a978-cb513c49c153"}}}], "length": {"value": 0.109333, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "93bde77a-daea-4cd1-9aac-96608150fd7e", "name": "l(r:p1rdt8012lv-p1rlv17069)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5b22c57-7912-4e9f-9b06-6a8ff706a58d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd48a076-5f8f-426a-b294-183700d1a123"}}}], "length": {"value": 0.0628588, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c75878bb-a8e9-45f7-ac9f-3112ab4daa2e", "name": "l(r:p1rdt8015lv-p1rlv17001)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6c5d7ff-cfcd-4b30-98db-eb44a95d6841"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f23214ee-3032-4403-9084-8117e89cb1cf"}}}], "length": {"value": 0.00814411, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4a06edff-3ac9-477f-afd1-857950e98149", "name": "l(r:p1rdt8015lv-p1rlv17028)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6c5d7ff-cfcd-4b30-98db-eb44a95d6841"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "213e6d98-ad57-4034-b2d0-4b096554cac2"}}}], "length": {"value": 0.00814411, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "963a379d-4526-40c4-a92c-040fcd1db98c", "name": "l(r:p1rdt8034lv-p1rlv17059)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "972fe574-f88e-4a8d-8845-d5baa2f378a7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "92aff718-b70f-4ea4-b38b-fae69a470c58"}}}], "length": {"value": 0.0530471, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "39ed0258-6338-449e-a516-59e9a08220e0", "name": "l(r:p1rdt8149lv-p1rlv17319)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9951633b-4311-4ca2-9316-3801be13fe97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9778ed5-f0c0-44de-b0d4-60659a54fa3b"}}}], "length": {"value": 0.0160827, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cee2f792-d80f-4b98-a645-57496b1a1a4e", "name": "l(r:p1rdt8149lv-p1rlv17334)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9951633b-4311-4ca2-9316-3801be13fe97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4970bc03-bc57-4a42-b0cb-66002af1709e"}}}], "length": {"value": 0.016006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1df0e133-12a9-410c-ac98-560dfc4918f0", "name": "l(r:p1rdt8150lv-p1rlv17320)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cd1ae47-6aaa-4b57-ba44-1e74f6ea54b7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79991b02-c0f1-4b9b-a55e-e9b4ff7c17d9"}}}], "length": {"value": 0.063086, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "815c3299-4558-40b9-b5fe-d5f0c27c11d7", "name": "l(r:p1rdt8150lv-p1rlv17326)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cd1ae47-6aaa-4b57-ba44-1e74f6ea54b7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ceb2d77-2da7-44df-9f28-69ed35835775"}}}], "length": {"value": 0.063086, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "499d0139-fa5c-45de-864f-e28786ab80fa", "name": "l(r:p1rdt8151lv-p1rlv17321)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a8deb5-b46b-4d4c-876c-b44b2258a6fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "00ed745d-78ae-47f6-b6ef-4edf8794ca6a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "4d608ad4-d94a-4b0b-8fcd-3c08ae50178c", "name": "l(r:p1rdt8151lv-p1rlv17321)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "00ed745d-78ae-47f6-b6ef-4edf8794ca6a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94ce8ee2-6f57-407a-93e9-c06f79d66262"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "4dceb5ed-b8a7-4331-90f0-5f93186eeaba", "name": "l(r:p1rdt8151lv-p1rlv17321)_s2", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94ce8ee2-6f57-407a-93e9-c06f79d66262"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce41ac7c-06c5-435a-957d-c9dda83c1893"}}}], "length": {"value": 0.09433530000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d09084bb-a89a-4254-a73c-e94d3dc90fbd", "name": "l(r:p1rdt8151lv-p1rlv20188)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a8deb5-b46b-4d4c-876c-b44b2258a6fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abb24254-be79-45d4-8d9b-246b3e89c00f"}}}], "length": {"value": 0.00615959, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4ef03455-4b06-4b8f-af90-475cc6a09a60", "name": "l(r:p1rdt8153lv-p1rlv17325)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a542ca5-b24e-44dc-8b68-c00aa024afad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b96606c-9336-4299-be8d-295c84943a9d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "23108ceb-470b-432b-b6c3-701d156a5397", "name": "l(r:p1rdt8154lv-p1rlv17328)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32fefbef-e10b-4758-8c2e-ccafad49aa5d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a43eb022-d5e0-47c8-aa36-6ca0d212ab07"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "36ad5faf-d994-41eb-afb8-9a4fb8edcf6c", "name": "l(r:p1rdt8155lv-p1rlv17329)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51812cd8-eec8-4862-8413-d25a7e9862dc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61ef37c1-f14f-4b79-a428-d51a6f0d076a"}}}], "length": {"value": 0.0793038, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b52124cd-a5c9-4f18-9f6d-79b8143d4cef", "name": "l(r:p1rdm17903-p1rlv17330)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb2a5041-28a1-4fda-905b-caf53ebbefe3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48ad7bb0-8dd7-457a-b77d-6db2071c2fe7"}}}], "length": {"value": 0.0025319, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "11874623-6a90-44c5-b716-1180ab27ebdb", "name": "l(r:p1rdm17903-p1rdt8155lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51812cd8-eec8-4862-8413-d25a7e9862dc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb2a5041-28a1-4fda-905b-caf53ebbefe3"}}}], "length": {"value": 0.0391228, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a670c5be-e502-4ee5-bab3-d6830776dd9c", "name": "l(r:p1rdt8157lv-p1rlv17333)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa6d4429-8a95-4ebd-9e3a-9867734245bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33b66eb9-3b21-4f92-b19b-6a0eef4134d8"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "3c168ea4-60f1-40d7-9105-c60ebe5c0919", "name": "l(r:p1rdt8159lv-p1rlv20480)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1dd4660-3cd0-4709-b1ef-1c598e5e39fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5d0a174-d49d-4c7e-a669-092f6408edf4"}}}], "length": {"value": 0.0224012, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "42b10885-9f84-40fb-8096-ecdeabc0172c", "name": "l(r:p1rdm17907-p1rlv17336)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3484e698-3a4e-4a88-aaa3-1dc88cd9ac89"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b645969-9136-42a9-b5ac-7d2f1ff71959"}}}], "length": {"value": 0.0155741, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "711295b2-6d63-413f-8284-ba2877d64e97", "name": "l(r:p1rdm17907-p1rlv20492)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3484e698-3a4e-4a88-aaa3-1dc88cd9ac89"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7af262b7-285c-4d06-b7ff-2f2a1971055a"}}}], "length": {"value": 0.049942, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "daa257f3-0092-4324-ba2d-11ec7a94a4a1", "name": "l(r:p1rdm17907-p1rdt8159lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1dd4660-3cd0-4709-b1ef-1c598e5e39fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3484e698-3a4e-4a88-aaa3-1dc88cd9ac89"}}}], "length": {"value": 0.018672500000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2cbdeb9d-3636-4393-9326-b0240390e325", "name": "l(r:p1rdm17908-p1rlv20455)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6112cc26-bc37-4c72-8ef6-cd88f1296693"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8934db59-0c39-4838-9f8c-59a563cd9d54"}}}], "length": {"value": 0.0215008, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "06e87fff-fd19-45b8-bb9b-8cd0c6413c5a", "name": "l(r:p1rdm17908-p1rdt8159lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1dd4660-3cd0-4709-b1ef-1c598e5e39fb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6112cc26-bc37-4c72-8ef6-cd88f1296693"}}}], "length": {"value": 0.0175631, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9a093498-1758-4c33-8c70-ea251e449258", "name": "l(r:p1rdt8160lv-p1rlv17337)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "232fed6b-fe0f-4a44-93e9-e6675b50c39c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5d7049e-9d30-474c-9033-3ad9b4487f7a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "259d0df0-c158-431c-8a14-d3db5f371846", "name": "l(r:p1rdt8161lv-p1rlv17338)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac7e489e-7249-4702-9ed6-131cad34500f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "331389ab-5d04-4648-83b4-3043198c774f"}}}], "length": {"value": 0.05601040000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "56875cf5-044e-43c9-b940-eee8bd16a486", "name": "l(r:p1rdt8346lv-p1rlv17702)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9560197a-21d1-4601-8bcb-213df4844f4a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7acb4e7d-cb06-4848-952d-7c68bb34b6db"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "e6dddecc-acad-4d45-849a-d67e98fe7205", "name": "l(r:p1rdt8405lv-p1rlv17781)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "408d5d7b-fc71-46bb-8de0-2d4e628c29b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a52db2ff-b782-40c1-828a-c65f6929b2fc"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b38ef92b-b5a5-4354-a862-4ff2cfcaf0e2", "name": "l(r:p1rdt8408lv-p1rlv17787)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3fe0f77-a7c1-48e3-94aa-30b69f20ca65"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c9c1d9f-eeff-454f-b3d0-7e7de837694c"}}}], "length": {"value": 0.030519200000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d2fdb455-533e-494f-b3ae-7a6f434a6456", "name": "l(r:p1rdt8408lv-p1rlv18044)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3fe0f77-a7c1-48e3-94aa-30b69f20ca65"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b40fac8c-a99b-4baa-940a-26565ba7d62b"}}}], "length": {"value": 0.030519200000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2cccc34f-8ec9-4a07-94e6-5ea9394c8395", "name": "l(r:p1rdt8414lv-p1rlv17798)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fca92353-c013-4c41-8507-ec8704410834"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9dba02d-086c-4906-9c6f-86532e3384c0"}}}], "length": {"value": 0.0626486, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3fa99df5-af3e-4d19-92fe-6c6b8fa2435f", "name": "l(r:p1rdt8422lv-p1rlv17810)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfe35c35-8164-4825-81e3-10a2ece2cb27"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3887a879-0783-4703-8a24-32b7e3b4f39d"}}}], "length": {"value": 0.064621, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "29fcd1b6-7f66-4926-8f32-6b14ca47aa39", "name": "l(r:p1rdt8422lv-p1rlv17847)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfe35c35-8164-4825-81e3-10a2ece2cb27"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f7776e4-a81f-48d2-b3c0-d70bfa48164e"}}}], "length": {"value": 0.114619, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6a2c3743-a96c-4193-afff-9f66a9993e4a", "name": "l(r:p1rdt8422lv-p1rlv17876)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfe35c35-8164-4825-81e3-10a2ece2cb27"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75e55237-b847-4fb7-a141-a0771bd868c6"}}}], "length": {"value": 0.0889709, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1cfd7122-29e2-4593-8a29-d37c7bab1574", "name": "l(r:p1rdm18545-p1rlv17961)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7421f5c-bf5c-4d01-aa14-ba657f242080"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2716887e-1701-4a78-805b-96da0781c7f8"}}}], "length": {"value": 0.07666780000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1fc0a354-eb4d-4fef-b7b3-9ac5204835bf", "name": "l(r:p1rdm18545-p1rdt8422lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfe35c35-8164-4825-81e3-10a2ece2cb27"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7421f5c-bf5c-4d01-aa14-ba657f242080"}}}], "length": {"value": 0.0192775, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6813915a-9540-4a06-8171-305ffaddeb8f", "name": "l(r:p1rdt8434lv-p1rlv17857)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdc5ef2a-c0d0-4702-b6c6-df08af1e8746"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0827675c-2467-403d-822e-5f74cd6296c5"}}}], "length": {"value": 0.0235179, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ae004d86-bb53-4a39-b217-28aba419df2a", "name": "l(r:p1rdt8436lv-p1rlv17877)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b24c9345-625f-499d-96cf-30b2de5839b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f44b0293-61e5-4054-b2d7-4a113df92b3c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "90848665-6e77-434a-9664-022c4b37b0ca", "name": "l(r:p1rdt8439lv-p1rlv17897)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a38f544-e250-4fc9-942c-946c5cde0a33"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f74f217-4765-406d-9646-d8f46377ef0a"}}}], "length": {"value": 0.0231504, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "615ebf6f-8bb0-491b-a80f-70ff9109b5c5", "name": "l(r:p1rdm18631-p1rlv17909)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6460e5c-839d-4f9e-b9d6-b187fddb9ab6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab733d49-bb36-4631-8824-1967f98f758a"}}}], "length": {"value": 0.055777700000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9d77603e-e62a-40c8-8d7b-5150e4e96a38", "name": "l(r:p1rdm18631-p1rdt8440lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "049362b4-49de-4e80-921e-ff763aaab2d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6460e5c-839d-4f9e-b9d6-b187fddb9ab6"}}}], "length": {"value": 0.017871200000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "48a7466b-1d73-416b-809a-83537dd3441d", "name": "l(r:p1rdm18632-p1rlv17969)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7633fe6b-a48b-4e7d-90e6-a38b8a861936"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ccaf70a-35d8-4f16-b632-e282fe30b5ca"}}}], "length": {"value": 0.018069200000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "19cb6fa7-25c3-47ca-a366-957be38b8701", "name": "l(r:p1rdm18632-p1rdt8440lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "049362b4-49de-4e80-921e-ff763aaab2d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7633fe6b-a48b-4e7d-90e6-a38b8a861936"}}}], "length": {"value": 0.0178577, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2caa96e4-c274-43dc-b1e4-5f11301d9ccf", "name": "l(r:p1rdt8441lv-p1rlv17912)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72c8f08a-0ba5-413e-a805-f9436b41ff29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3eb66d3-0271-4842-8893-9a58f64e0279"}}}], "length": {"value": 0.009300020000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "323d26e7-5b43-454b-a45c-aec7e307de9d", "name": "l(r:p1rdt8442lv-p1rlv17926)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b5ae28a-95f8-4023-aa23-36809fe96b10"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2812bbb1-0bb0-499f-a394-0995784bb7bc"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "186217d6-9a20-48aa-9949-c80f28bafe57", "name": "l(r:p1rdt8444lv-p1rlv17960)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "978920e8-edf9-4bee-85f9-45f4081ed0ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "215a5974-e23b-46f0-bde9-f5ad16fdfaf8"}}}], "length": {"value": 0.00946867, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a2666500-718c-4b6a-b104-d85550e22cdc", "name": "l(r:p1rdt8444lv-p1rlv18071)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "978920e8-edf9-4bee-85f9-45f4081ed0ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86917829-123c-4fda-9809-dc61430a9fef"}}}], "length": {"value": 0.00946867, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "af700dca-e6b2-417d-a811-cc93dc290724", "name": "l(r:p1rdt8445lv-p1rlv17962)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e0923da-550b-479f-b3d8-3e0320db6701"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec99daac-e0be-4ea1-ba4f-185d4943396d"}}}], "length": {"value": 0.07683860000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "529ee728-9a14-4ce5-bbf5-baa1001689c5", "name": "l(r:p1rdt8447lv-p1rlv17987)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5dbc3459-6a17-4075-899a-6aab16fb3ab7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0771ebfa-5eaf-4ae8-94f1-86de7a656f58"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "04dd8850-4fe7-4c15-8a87-50bc76145038", "name": "l(r:p1rdt8450lv-p1rlv18053)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b4216c8-9e99-446c-ad09-5a09f046dd59"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4aeda1c7-41be-43c8-82e5-d7a347db86a8"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "63c8dbef-8a8b-4ce8-95cf-6fc4728d963d", "name": "l(r:p1rdt8456lv-p1rlv18100)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d094b779-ebcc-4837-9ccb-31808e2a544b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4863d28-4ee2-479d-accb-60b54f472fe7"}}}], "length": {"value": 0.04190880000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "300dd493-34b4-4375-892d-eadd8fe22746", "name": "l(r:p1rdt8458lv-p1rlv18129)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e597d8da-e876-44a5-a109-1ce84527c557"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "115a848f-f6f3-48f0-9f33-5a9103f1a892"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "43c4c411-e502-46b8-9442-5f4d7dd2ea62", "name": "l(r:p1rdt8470lv-p1rlv18166)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "edb15d92-f98a-4fa2-8129-ad8a39e0dc0c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "431692e5-2917-41ea-aafc-96be180b7e27"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "be9ad055-8cbd-4405-8241-9bc60395472f", "name": "l(r:p1rdt8490lv-p1rlv18192)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a84e1424-7faf-4077-9461-b39460f10ef0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c3e08a8-ea88-423d-b361-69509f7ab8fa"}}}], "length": {"value": 0.0095095, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bdc387c3-9bdc-43d9-890f-0d718eba7c3a", "name": "l(r:p1rdt8490lv-p1rlv18198)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a84e1424-7faf-4077-9461-b39460f10ef0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a7cb078-af6c-4cd5-9aca-48f515f6e711"}}}], "length": {"value": 0.0095095, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f668b67f-606b-4d28-9cc3-1943007f22e4", "name": "l(r:p1rdt8492lv-p1rlv18197)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "127e4cc7-6413-4482-9ec3-40f8bde02d0c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5e240e8-b27d-4181-a7ee-a004d3f5c58a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "81b9170e-c68f-4cac-a3d4-fbc567e0a98c", "name": "l(r:p1rdt8802lv-p1rlv18960)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95a1a7c7-6055-47c9-a742-c1b81f6c7478"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9178fdee-311f-40f5-bdd6-9b474a05247e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "5c797127-ea67-442a-b638-200eacfd668c", "name": "l(r:p1rdt8805lv-p1rlv18967)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "715c92fa-2470-4869-8d5f-0b4f3f8360d4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eef4f0cf-6e51-45e1-8b6e-84171f7cbef6"}}}], "length": {"value": 0.0733915, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "dd30ae2e-bd36-4ebb-abb3-ba2b2c134191", "name": "l(r:p1rdt8898lv-p1rlv19157)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6ff626c-d2fc-4b97-9013-4fd544d946a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cf28b5d-d8d4-4883-a396-2d1ad9b70564"}}}], "length": {"value": 0.0657162, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "147a1cb3-41c2-49b8-8b56-b4683e957a72", "name": "l(r:p1rdm19752-p1rlv19149)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09d59048-6e1b-4f7f-b161-81163809eb25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67a4600d-65c3-40d7-ad28-e8e37ff77dcb"}}}], "length": {"value": 0.046789, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "0ca56993-e151-46ec-bc06-2732eef8e2a4", "name": "l(r:p1rdm19752-p1rlv19160)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09d59048-6e1b-4f7f-b161-81163809eb25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7c1d210-ee87-46c5-b408-ad221cbeed04"}}}], "length": {"value": 0.057637900000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "d4f9decd-9338-4453-85d3-5c8b5ac0490f", "name": "l(r:p1rdm19752-p1rdt8898lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6ff626c-d2fc-4b97-9013-4fd544d946a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09d59048-6e1b-4f7f-b161-81163809eb25"}}}], "length": {"value": 0.019358300000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "cb6ddaa3-2b16-42bd-bce5-bd8a267eab2f", "name": "l(r:p1rdm19755-p1rlv19166)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7664d29-bbc0-4465-a00a-82af048b86e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "994f6392-f4e5-4ff8-9eeb-5849cd035912"}}}], "length": {"value": 0.0880892, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "6a7bb342-4fcd-424d-861f-0ee25541d40f", "name": "l(r:p1rdm19755-p1rdt8898lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6ff626c-d2fc-4b97-9013-4fd544d946a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7664d29-bbc0-4465-a00a-82af048b86e5"}}}], "length": {"value": 0.0437869, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "f229b79a-47fa-4ab8-9ea2-b416d4caf8fc", "name": "l(r:p1rdt8901lv-p1rlv19161)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d53c0a2-78cc-4988-85a4-884ef039f5fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16df6b90-d049-4160-b148-b888e03acb82"}}}], "length": {"value": 0.0671759, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6bdd0d1e-8826-457f-a773-5a2a945a84ce", "name": "l(r:p1rdt8904lv-p1rlv19168)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e111e213-bcbe-42c4-b6ab-2c734ff5341c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f8c76ca-40ea-4f7d-8042-66edd484f065"}}}], "length": {"value": 0.045782800000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "741a9472-dbc2-427c-a02b-462c15f35f7b", "name": "l(r:p1rdt8904lv-p1rlv19174)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e111e213-bcbe-42c4-b6ab-2c734ff5341c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0fc7d43-4f82-4100-99bf-6e30e03e95ce"}}}], "length": {"value": 0.0128136, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "96ca1afa-d534-4724-8ecb-b6702cfd67b7", "name": "l(r:p1rdm19776-p1rlv19184)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b9386f2-376d-4439-a9a4-3eefc238dafe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50750ddb-80db-4d5f-bc62-4bbfc600a7ef"}}}], "length": {"value": 0.075847, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "72bd06c1-2522-4912-ab13-24cec5f2b774", "name": "l(r:p1rdm19776-p1rdt8904lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e111e213-bcbe-42c4-b6ab-2c734ff5341c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b9386f2-376d-4439-a9a4-3eefc238dafe"}}}], "length": {"value": 0.010418900000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a90947b1-4fd1-4387-bdff-d59c20a3fb90", "name": "l(r:p1rdt8905lv-p1rlv19169)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2777cc-f3fd-491f-a10b-4ed381cb948d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4e8183-9148-477e-aa1b-ff31a5324273"}}}], "length": {"value": 0.0299426, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "04d7afca-c271-4057-ab48-201ee8bcd8a3", "name": "l(r:p1rdt8905lv-p1rlv19171)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2777cc-f3fd-491f-a10b-4ed381cb948d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fffe26f7-c4cc-420e-ab17-754cb0d9e659"}}}], "length": {"value": 0.0502658, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "21e7a836-3ea5-407e-bd70-f3443102eebd", "name": "l(r:p1rdt8905lv-p1rlv19173)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2777cc-f3fd-491f-a10b-4ed381cb948d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21fec301-b67c-4042-a074-caf406c7f0b5"}}}], "length": {"value": 0.0431542, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7c1587be-1e8f-466e-8791-3a41354606c0", "name": "l(r:p1rdt8905lv-p1rlv19188)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2777cc-f3fd-491f-a10b-4ed381cb948d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47e24942-486d-46f1-a40f-0da5c93c013a"}}}], "length": {"value": 0.00975868, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4637e31d-b157-4290-a8cb-4596fb7db783", "name": "l(r:p1rdt8905lv-p1rlv19194)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2777cc-f3fd-491f-a10b-4ed381cb948d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7daa1d3-6249-447d-a260-65de5ec0a470"}}}], "length": {"value": 0.0629287, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3bca6f74-5988-47c8-a80c-3cd6b0a69bb6", "name": "l(r:p1rdt8911lv-p1rlv19183)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c306f79a-0240-465e-a486-d0f11614fc57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "89bde057-807b-415c-9135-267c6bf43c44"}}}], "length": {"value": 0.0132248, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7550f50f-c63b-48ad-8fdd-dc45f65120ce", "name": "l(r:p1rdt8911lv-p1rlv20296)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c306f79a-0240-465e-a486-d0f11614fc57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a8ae6dc-884d-48d8-9995-fe3936ad019c"}}}], "length": {"value": 0.0132248, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "418f522f-9800-4e1d-a31b-cf04a40a6664", "name": "l(r:p1rdt8915lv-p1rlv19189)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2fbbca23-6473-4344-ac2e-cc97078b3d8d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5fecc64a-4783-4ecb-a0d0-7e60d1cf6184"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "632311c1-925c-4de3-92fc-6b27efe14c9f", "name": "l(r:p1rdt8916lv-p1rlv19190)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d268e33-708d-4bae-8348-cad27fd0d81a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4aee02d4-8663-455b-a197-55b6b1470895"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "40f4ca55-ed5c-4973-971b-35cd67ba354e", "name": "l(r:p1rdt9075lv-p1rlv19667)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6752e8f4-9e37-476d-aec2-4a2fe7c1e2dc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33dcb037-4cc8-480f-aac4-bc95e54e165e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b4340e3d-5abb-4a2e-ab02-77baaf44385e", "name": "l(r:p1rdt9076lv-p1rlv19698)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdd64386-e256-47f8-8cef-1c933f993a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14b1ab4e-b22d-4a98-8131-fc72c923c735"}}}], "length": {"value": 0.055055700000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7a80ce41-b341-4153-b901-ce184294afbb", "name": "l(r:p1rdm20204-p1rlv19668)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd00c91a-01a8-4aad-b740-b06a654d631b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6427f66-2e22-40bb-83f1-2a8b1be9191a"}}}], "length": {"value": 0.0202803, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "049118fd-f5d6-4f65-9749-8f71e013199a", "name": "l(r:p1rdm20204-p1rlv19699)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd00c91a-01a8-4aad-b740-b06a654d631b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48654a82-ac11-4542-94ec-8f731138e1a8"}}}], "length": {"value": 0.0338608, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2c76a5dc-ab24-4233-b561-76095bf798b1", "name": "l(r:p1rdm20204-p1rdt9076lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdd64386-e256-47f8-8cef-1c933f993a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd00c91a-01a8-4aad-b740-b06a654d631b"}}}], "length": {"value": 0.0174413, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "eb46a639-7f1d-4e52-9a81-3b86dadfb400", "name": "l(r:p1rdm20205-p1rlv19686)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce8f50bb-90fb-49b8-8a16-1bbbb6a0c82c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47f5777d-2c8d-48c2-bf28-386f3f3dbac4"}}}], "length": {"value": 0.0229841, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "172f2ac8-d408-43a5-8f2f-85b7eb96c199", "name": "l(r:p1rdm20205-p1rdt9076lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdd64386-e256-47f8-8cef-1c933f993a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce8f50bb-90fb-49b8-8a16-1bbbb6a0c82c"}}}], "length": {"value": 0.017440300000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "642532af-cf6d-4892-bfa9-52b019bfbf8a", "name": "l(r:p1rdt9077lv-p1rlv19669)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b83eaaa-a092-42ca-a746-db4d9658d62b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96d3079a-02f1-4c89-ad75-fd0a438c9cf4"}}}], "length": {"value": 0.0293066, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b1bf45c3-70c8-4201-8c1a-d7d811dc7e70", "name": "l(r:p1rdt9077lv-p1rlv19675)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b83eaaa-a092-42ca-a746-db4d9658d62b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0031ab1b-d82d-40a5-b41e-bc6f6cb53069"}}}], "length": {"value": 0.00129939, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "a2668d78-c842-45e2-aeba-92c501e738bf", "name": "l(r:p1rdt9077lv-p1rlv19695)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b83eaaa-a092-42ca-a746-db4d9658d62b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35fe21a1-f817-426e-9e42-f1f33876dd7d"}}}], "length": {"value": 0.0295629, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7c77322f-3c54-4db1-b408-c1bcda2a0af3", "name": "l(r:p1rdt9084lv-p1rlv19681)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f0e4f59-8a46-4abf-9f06-e0383a59a45d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83afc678-d577-4ef1-afa2-8e3f915a158b"}}}], "length": {"value": 0.0407307, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ef70211b-06c5-4723-acbc-8f9aa7fe7d51", "name": "l(r:p1rdt9085lv-p1rlv19682)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "565bbfb1-a28f-4db2-be48-cbd58972025a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "811acd48-b61c-4a42-b76e-f995961c450e"}}}], "length": {"value": 0.0479288, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3052d3d1-b680-42ca-9619-45b322a57260", "name": "l(r:p1rdm20223-p1rlv19701)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec27727b-2bb8-4df2-9ddf-46282728c2c0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b5d936f-b3e0-408e-aabd-d3ebb7b869b0"}}}], "length": {"value": 0.05942600000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8693b634-c1ba-4076-b23e-61ae440e0c6b", "name": "l(r:p1rdm20223-p1rdt9085lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "565bbfb1-a28f-4db2-be48-cbd58972025a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec27727b-2bb8-4df2-9ddf-46282728c2c0"}}}], "length": {"value": 0.0186112, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4af17e9c-30e9-42ab-a616-44bee74bb9ea", "name": "l(r:p1rdt9089lv-p1rlv19689)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8108ac8-2807-4a40-85c2-db21efaadadb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "578b5df8-1dd8-41d9-b6dc-db75db5b115e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "a1434937-97ae-4da2-89f7-ebd1a788eb6a", "name": "l(r:p1rdt9090lv-p1rlv19690)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fc84159-09b1-4ca9-9a7a-a4fecab19f83"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2709a70-1a7d-454c-90fd-377e416a0071"}}}], "length": {"value": 0.0658315, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "67edc557-f853-458b-902b-2b073085da46", "name": "l(r:p1rdt9091lv-p1rlv19692)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e93ea18-150d-4d80-bac7-f3e1b87c5b4e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b10b272a-2efb-4e19-9921-d4081fb45778"}}}], "length": {"value": 0.0495767, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "86030b36-5fb5-416e-9704-398ab3aab79f", "name": "l(r:p1rdt9093lv-p1rlv19702)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f0726b7-3050-4c78-9c06-b9fd0c863ff3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37f72c85-61f7-4a42-94b0-6a627195458c"}}}], "length": {"value": 0.0423003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "41164760-4968-427a-ab0d-54100e9f5dc4", "name": "l(r:p1rdt9264lv-p1rlv20064)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c01a9b2-b002-4279-905e-950452f64f32"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aaea76fa-797e-46c5-a70f-a973977db841"}}}], "length": {"value": 0.0166628, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5e7381fe-5c31-423e-aa3a-7d6619d0c6d3", "name": "l(r:p1rdt9264lv-p1rlv20065)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c01a9b2-b002-4279-905e-950452f64f32"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea48ffa1-bdb3-4c15-96c9-ff7d7f34824f"}}}], "length": {"value": 0.0166628, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b84af902-253c-4e92-9494-157b730e98d1", "name": "l(r:p1rdt9265lv-p1rlv20066)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "77d62813-61d3-4afd-9f21-869e2ea23e17"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f450eeb4-3d87-4ae5-a6d6-958d7efd2712"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "2f422366-4e22-4f2c-8d50-1c6ba8a3374c", "name": "l(r:p1rdt9266lv-p1rlv20067)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78278589-be2d-4d99-9c03-92c221348917"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66a710fb-26c7-4465-b7ea-43ec107008dc"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "4f7d87f3-0ea4-4d93-b95a-cbe87c41dbc3", "name": "l(r:p1rdt9298lv-p1rlv20130)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "208f222c-45db-445f-ba0b-a4a195ca68a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ffc82be6-f3f8-4a68-b6e6-da60b137329c"}}}], "length": {"value": 0.0378956, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "bfcb695e-ecef-4564-813d-f2cb6bad6682", "name": "l(r:p1rdt9302lv-p1rlv20138)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180fad26-0e7d-4e2c-ba17-c8e3315ca278"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d635a151-2d13-47e9-8043-a214415a5b5e"}}}], "length": {"value": 0.057895600000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "39176fb1-de94-4c16-b64e-596ad25ee5f4", "name": "l(r:p1rdt9310lv-p1rlv20146)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4940a0e-dcc2-45fb-baa9-aadc84f8e882"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d615e93-a289-41ec-bda0-3b72bf15677e"}}}], "length": {"value": 0.052341200000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "71d34c49-4330-4c50-990a-3197e3ca5532", "name": "l(r:p1rdt9311lv-p1rlv20147)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9e0aa7d-9097-4370-8f5e-52a5885da85c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16b2add7-6a6d-4359-ad6f-f60edf435a4c"}}}], "length": {"value": 0.0259737, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8f3ee985-bbf9-4676-98e9-06a7c1d0a3d7", "name": "l(r:p1rdt9311lv-p1rlv20163)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9e0aa7d-9097-4370-8f5e-52a5885da85c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e938635b-e0d2-4e1b-a312-5a8f51e1dd7a"}}}], "length": {"value": 0.0357477, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ef39c360-8161-46c8-91bb-76651bc2d55f", "name": "l(r:p1rdt9312lv-p1rlv20148)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a21f5ca-51ef-4f81-8229-163182f011cf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4a0c2f2-f75e-4c9c-b3f7-d8d9ada9cb82"}}}], "length": {"value": 0.0268922, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3e7fdcaf-686b-496f-b34f-388785ad42a5", "name": "l(r:p1rdt9312lv-p1rlv20160)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a21f5ca-51ef-4f81-8229-163182f011cf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27dfea92-734e-49d3-b245-dc933df66889"}}}], "length": {"value": 0.0268922, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bc01fb01-4d37-4631-af7f-19d7e8269bbb", "name": "l(r:p1rdt9314lv-p1rlv20473)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3df13d91-365e-411b-917d-b28df5989280"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3eb214b9-827f-4995-a862-907be02b029d"}}}], "length": {"value": 0.0624435, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f48d1d5e-4709-4de9-b25d-ef596616a9fe", "name": "l(r:p1rdm20686-p1rlv20151)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5930295-0e44-4498-ae22-7647b72c1fa1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "956f4975-7383-4e0b-9114-d333a6ec4005"}}}], "length": {"value": 0.0773067, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c8ae9e69-9a3a-410a-9fd2-5ad1838b01c7", "name": "l(r:p1rdm20686-p1rlv20456)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5930295-0e44-4498-ae22-7647b72c1fa1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7a43aa6-2be8-4320-8089-57d388633c6b"}}}], "length": {"value": 0.0422263, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "97870ca0-fce4-48b0-85c2-87b76b884161", "name": "l(r:p1rdm20686-p1rdt9314lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3df13d91-365e-411b-917d-b28df5989280"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5930295-0e44-4498-ae22-7647b72c1fa1"}}}], "length": {"value": 0.0198942, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3435161e-0808-453b-ade5-697634ed4656", "name": "l(r:p1rdt9316lv-p1rlv20153)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c97a99f-545b-49cd-b1fe-4fd9e04bf37f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef20846d-d685-4c65-8dfb-bc23317501c5"}}}], "length": {"value": 0.021752800000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "633b6dd6-6a15-47ed-9d97-aebf2d9b5b6d", "name": "l(r:p1rdt9333lv-p1rlv20182)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a68a1c01-a04c-4af6-b1c8-02ddd1d67e0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20f93381-3834-4265-b1ec-5767d171ce0a"}}}], "length": {"value": 0.0263788, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b3b2c026-7b70-40e5-8478-180fd8809d5e", "name": "l(r:p1rdt9377lv-p1rlv20277)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e98299cb-8bad-49ea-8627-f3cfe01b9e23"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb7a8747-a076-469c-a150-35f6763157ec"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "087026c8-269c-4769-9c6f-af9a90b11306", "name": "l(r:p1rdt9381lv-p1rlv20281)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e37f182-5a60-470d-8f5b-ba145cc27973"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f23405b-432f-45ff-a7b1-0b7147cddfc8"}}}], "length": {"value": 0.0253793, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "59b8b45a-c9f3-49e3-8323-0d7dd87f9cb1", "name": "l(r:p1rdt9381lv-p1rlv20309)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e37f182-5a60-470d-8f5b-ba145cc27973"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e5718ad-0b70-4ea4-b2f2-31f0ea5c5d5b"}}}], "length": {"value": 0.0253793, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "26c34058-4892-4440-845b-5d3851809b0c", "name": "l(r:p1rdt9384lv-p1rlv20284)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abd09ea6-221c-47d9-beec-1062e0dd4aa7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25837ab0-0fb8-4346-94ad-561ff9ff7f0c"}}}], "length": {"value": 0.00420309, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9c16c054-b1ff-4e91-9010-39b32b8e0c3c", "name": "l(r:p1rdt9396lv-p1rlv20300)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc7e0a25-d6d6-4b07-b3dc-4fe5646915e2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da62d78e-e221-423a-8da0-8d36ce1f7508"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "d348f254-0831-467d-a2cf-24cff48b1fdc", "name": "l(r:p1rdt9413lv-p1rlv20333)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8180ee90-a46e-4d85-9742-d47b24f5e169"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c23afdc0-ab93-4d43-8eec-613eab21cd74"}}}], "length": {"value": 0.055563600000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d39e9443-e092-4bb9-890c-ec952b4704b1", "name": "l(r:p1rdt9413lv-p1rlv20358)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8180ee90-a46e-4d85-9742-d47b24f5e169"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b5d2dfa-895b-4afc-a7fe-449960adba41"}}}], "length": {"value": 0.055563600000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "5bf01fa7-0a38-4b2d-b944-93837af9be6a", "name": "l(r:p1rdt9463lv-p1rlv20432)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a015abb-ec63-4b31-9314-283b8499646e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4b5327a-85a3-496c-859c-f887a38513cd"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "e58c5ea4-bad0-4ebb-8dbd-9ba73b522dc9", "name": "l(r:p1rdt9468lv-p1rlv20451)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4dbe1628-cd17-4f37-af2b-dd752c290fa4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c37708d8-1e83-4e76-ac7f-0d29ba6b7c4e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "d36d6ce0-a328-49e6-8589-761a2846b82e", "name": "l(r:p1rdt9469lv-p1rlv20453)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09613257-d4cb-4c50-b35a-8aefc637c0c9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4e21b79-d2be-4a53-be46-32331e61f89c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "607be846-24c7-4d25-9222-e26430fd02e8", "name": "l(r:p1rdt9470lv-p1rlv20459)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1ab8727-2758-4513-8a7d-e02381faf1e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dfcfdbf-0051-4eef-bea6-97446cee21e4"}}}], "length": {"value": 0.0117286, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "03097dee-3563-430d-b479-e6da3aad6765", "name": "l(r:p1rdt9470lv-p1rlv20499)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1ab8727-2758-4513-8a7d-e02381faf1e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af153ed-ed39-4433-ac12-19dfdb7b6bef"}}}], "length": {"value": 0.0117286, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "abbb58b1-e018-43c7-8d8a-c43034cd923f", "name": "l(r:p1rdt9473lv-p1rlv20465)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c14c3211-a0d5-464f-820c-cab04764d907"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4759390d-43ec-45c9-9cca-320020dc1150"}}}], "length": {"value": 0.0334443, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4d466a6c-7eae-4477-a58b-84b46559fe6e", "name": "l(r:p1rdt9479lv-p1rlv20502)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6a8f268-6a5a-4b23-bd91-53c6b031442a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cacd3e49-55aa-4f05-bd7d-ae8aba0af87f"}}}], "length": {"value": 0.0132405, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "35f3ce10-7ea2-43a6-92f7-0e66c65507eb", "name": "l(r:p1rdt16638lv-p1rlv38126)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac361065-6b3c-4ac6-96d5-9b474eb3b80f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa4eed95-33b7-4827-8744-52d14149b386"}}}], "length": {"value": 0.00896862, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "950103b1-9ec6-4ba5-b24d-ea8b8cb59b5b", "name": "l(r:p1rdt16725lv-p1rlv38269)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bae9a352-584d-4cf0-9ebd-eb280b684e78"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cbb9976-253c-4863-899f-9218c4496688"}}}], "length": {"value": 0.00555125, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cf1cfe51-e7f4-4574-8253-da4972b54c2b", "name": "l(r:p1rdt7983-p1rdt8012)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bfb33cd-0cf1-455d-81e7-3d0472fa1b41"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e261b565-1f57-4cdc-bdd6-e045ee55d290"}}}], "length": {"value": 0.319354, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3b48fbf7-1282-4f8c-a6a8-8ae9f3b90bbf", "name": "l(r:p1rdt8012-p1rdt8034)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f83d22a-fa1e-4a4e-aab9-a9dea8ee06e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bfb33cd-0cf1-455d-81e7-3d0472fa1b41"}}}], "length": {"value": 0.0383866, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6243de73-7829-4099-a0ab-20bbf6c6ecea", "name": "l(r:p1rdt7954-p1rdt8034)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21e15d54-eab8-4204-9ed6-407fd8684700"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f83d22a-fa1e-4a4e-aab9-a9dea8ee06e5"}}}], "length": {"value": 0.256854, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9953443a-e512-47b5-b2da-2f9e9ddca7fc", "name": "l(r:p1rdt7954-p1rdt7973)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "016e4575-cd41-4993-be9b-5e5236a139ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21e15d54-eab8-4204-9ed6-407fd8684700"}}}], "length": {"value": 0.0497607, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a53ed3ef-f09a-4551-b82a-b6207878ef9a", "name": "l(r:p1rdt5172-p1rdt7973)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ea481f8-b9c7-4067-9bfb-4f7cdc5dee15"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "016e4575-cd41-4993-be9b-5e5236a139ae"}}}], "length": {"value": 0.289407, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "2c820636-d095-4272-9f89-d921819ff2af", "name": "l(r:p1rdt5155-p1rdt5172)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16712e10-4c7f-428b-917b-135ab3c2d4b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "afc636ed-f90c-4c48-822b-e86890d36f3b"}}}], "length": {"value": 0.0981862, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "cef0b639-e95b-4129-9dda-79e15491f213", "name": "l(r:p1rdt5155-p1rdt5172)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "afc636ed-f90c-4c48-822b-e86890d36f3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ea481f8-b9c7-4067-9bfb-4f7cdc5dee15"}}}], "length": {"value": 0.03419850000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "42c7cdb3-0fc1-4744-a4cb-bdb92a0ec9f0", "name": "l(r:p1rdt5155-p1rdt5201)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c289632-ba52-4b65-b6da-ac76b1477246"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16712e10-4c7f-428b-917b-135ab3c2d4b3"}}}], "length": {"value": 0.163704, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0e56a149-003c-40f3-90b4-32c09c9a86eb", "name": "l(r:p1rdt5159-p1rdt5201)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c289632-ba52-4b65-b6da-ac76b1477246"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee606236-08d7-4258-96c9-e9104f15b467"}}}], "length": {"value": 0.247666, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c41ff1f4-216c-4b99-9559-edc06bc0b68c", "name": "l(r:p1rdt5159-p1rdt5201)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee606236-08d7-4258-96c9-e9104f15b467"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90fb2270-4759-4779-80c1-7f93d66e1c53"}}}], "length": {"value": 0.0252803, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3b106144-995a-42f6-9105-373bd1547600", "name": "l(r:p1rdt5180-p1rdt5201)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86d3f96e-ffe2-459f-a2f1-b63d7bf138b8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c289632-ba52-4b65-b6da-ac76b1477246"}}}], "length": {"value": 0.165958, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "64b0948b-beb3-4234-9522-002661698319", "name": "l(r:p1rdt5923-p1rdt8346)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fec8a81-a151-4d8f-adc7-6d6d87d7759f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14b429c3-41da-4123-b661-40cbdfaf33e0"}}}], "length": {"value": 0.457454, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9be8e2a3-ed3b-4de7-8f25-6382fec041a4", "name": "l(r:p1rdt5923-p1rdt7988)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48e4b67a-0a47-48f0-b787-0a639db89caa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fec8a81-a151-4d8f-adc7-6d6d87d7759f"}}}], "length": {"value": 0.342603, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "cfb719d9-877c-4453-87ef-d4b5173d026f", "name": "l(r:p1rdt5180-p1rdt7988)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "893d2436-cd6c-40ad-90af-64ba1ac23f6e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48e4b67a-0a47-48f0-b787-0a639db89caa"}}}], "length": {"value": 0.958025, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4d35cd22-a1ac-48df-ae3c-d5a13715712d", "name": "l(r:p1rdt8447-p1rdt8456)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0089e5ea-d706-4a74-812f-654ae73eabcf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13b8cfc1-d8eb-4f47-b024-c1daacf3771d"}}}], "length": {"value": 0.30374700000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b83c03fc-f796-48d3-ad3b-2a3a22f58722", "name": "l(r:p1rdt8414-p1rdt8456)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34054ef8-8942-4471-ac14-43c6a37e5a16"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0089e5ea-d706-4a74-812f-654ae73eabcf"}}}], "length": {"value": 0.05634, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9e912236-8d08-4c01-94bf-41467552e199", "name": "l(r:p1rdt6272-p1rdt6274)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a53624b-8538-4cce-b588-c774875af31b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ac93b23-1041-486e-a16e-861082c92f35"}}}], "length": {"value": 0.108002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1c2a2bab-c82d-4a38-b710-8c8dfebf7049", "name": "l(r:p1rdt6272-p1rdt6274)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ac93b23-1041-486e-a16e-861082c92f35"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "034bda10-d48e-449c-9255-247cbf718683"}}}], "length": {"value": 0.00825442, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "923cb400-a742-4e52-948c-6c7d6cb7de45", "name": "l(r:p1rdt6271-p1rdt6274)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a75c5e2-2277-42b4-87d4-6eadff5c06f1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a53624b-8538-4cce-b588-c774875af31b"}}}], "length": {"value": 0.307488, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0a09a81b-a804-4407-b341-726e2c473678", "name": "l(r:p1rdt6270-p1rdt6271)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28954596-f060-4fa8-9f13-dfaa633bb739"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "898611f5-c343-4cca-8e5e-60cf0bfd796b"}}}], "length": {"value": 0.188113, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1369a137-ea26-496f-a49e-07fe1c36db1c"}}}}, {"uuid": "fe825001-39f1-4eda-af62-9c33a676d4b2", "name": "l(r:p1rdt6270-p1rdt6271)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "898611f5-c343-4cca-8e5e-60cf0bfd796b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b81bd5c2-96bb-445e-9eb8-d72360fd8a94"}}}], "length": {"value": 0.0296898, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "adfdca16-9dd2-4e84-828b-3cce8ceeead1", "name": "l(r:p1rdt7564-p1rdt7579)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76f6a27f-0e4f-48b8-9dbd-31c6ffc4ec75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa33ca9e-e16d-4c49-8a70-c6c30cf7b038"}}}], "length": {"value": 0.243188, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e28fa3c8-8478-435b-b24b-b2050db2515d", "name": "l(r:p1rdt7579-p1rdt7588)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76f6a27f-0e4f-48b8-9dbd-31c6ffc4ec75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f2dabc2-0b52-490c-b13a-32c268f6bd33"}}}], "length": {"value": 0.243808, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6c30a9e9-21aa-474e-8386-513a617c20c9", "name": "l(r:p1rdt7554-p1rdt7579)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f6de990-0988-4126-86ca-d1fd72c555fe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76f6a27f-0e4f-48b8-9dbd-31c6ffc4ec75"}}}], "length": {"value": 0.573836, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "558e228e-253b-4a6e-b393-6b01faeae27a", "name": "l(r:p1rdt7554-p1rdt7570)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2bdb2b51-0526-4995-bb5e-a2bd495488d4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f6de990-0988-4126-86ca-d1fd72c555fe"}}}], "length": {"value": 0.0647236, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d49f4c2c-8d0f-47c4-ae4b-a90f17979c57", "name": "l(r:p1rdt7559-p1rdt8015)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f239ef4e-83f0-4a2c-ada3-8e30cef38472"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff343735-753a-48ca-92b1-ea778c9e0b5c"}}}], "length": {"value": 0.10196200000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c0c2911d-ed07-4990-9abb-bc36add87fd0", "name": "l(r:p1rdt7559-p1rdt8015)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff343735-753a-48ca-92b1-ea778c9e0b5c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc543f54-740b-4a7f-b1c5-eb3783a8ade0"}}}], "length": {"value": 0.286466, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b9996b9e-d092-40f7-9d2d-9e261c16d724", "name": "l(r:p1rdt7559-p1rdt7570)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09814176-7891-4fe1-addf-b47aa106c40d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1dbec6c9-5c87-4f56-bd92-4a30d39ad094"}}}], "length": {"value": 0.14637200000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e4a51fb5-8e76-46ef-b920-7b77c5a4d877", "name": "l(r:p1rdt7559-p1rdt7570)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1dbec6c9-5c87-4f56-bd92-4a30d39ad094"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f239ef4e-83f0-4a2c-ada3-8e30cef38472"}}}], "length": {"value": 0.0849739, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1e1ff4ea-e8cd-413e-9ecd-a6b8b712c351", "name": "l(r:p1rdt7552-p1rdt7986)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db899c48-a801-4f83-b59d-e587ba80019d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "93a5388e-ffd7-403e-b6cf-26b7e81feed1"}}}], "length": {"value": 0.384727, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3c9d4cb9-43a5-4fef-a47c-22f1e23a19f3", "name": "l(r:p1rdt7551-p1rdt7552)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f0f3112-1395-48bf-88c1-8dd4b171478d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db899c48-a801-4f83-b59d-e587ba80019d"}}}], "length": {"value": 0.306203, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "887efa1d-3a26-4b29-9ee7-cd4d24b4122f", "name": "l(r:p1rdt7550-p1rdt7561)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc6bd64f-1ad3-4bd9-b590-7d4b673a94b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dead8520-e2f5-499b-9316-77780f9b1dfe"}}}], "length": {"value": 0.102524, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b5dbbf64-d586-472c-be8d-ec4d30c9538a", "name": "l(r:p1rdt8434-p1rdt8450)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f28de397-0db4-486a-8ce6-9f65c68703b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "184f95d4-cde1-4bf1-8a74-ebc7097cb10e"}}}], "length": {"value": 0.130615, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "310b27c0-aeca-4713-8dd9-75634008b0ca", "name": "l(r:p1rdt8434-p1rdt8440)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bbfe31b1-38ce-4ae4-9143-bf08c81617e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f28de397-0db4-486a-8ce6-9f65c68703b3"}}}], "length": {"value": 0.151253, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9d08c952-2d6b-430a-8ac4-049ad384831f", "name": "l(r:p1rdt8436-p1rdt8440)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bbfe31b1-38ce-4ae4-9143-bf08c81617e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "516ca275-0d8e-4a9a-ab59-89cb66b95d93"}}}], "length": {"value": 0.149159, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5ee7bf52-8efb-40b6-af57-c62fd8cd3acf", "name": "l(r:p1rdt8436-p1rdt8440)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "516ca275-0d8e-4a9a-ab59-89cb66b95d93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fcc42825-2690-4965-a99b-e78285a9b84e"}}}], "length": {"value": 0.105337, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "da33cb2a-7eaa-4cfc-9c3d-2a5cb32b1ee0", "name": "l(r:p1rdt8440-p1rdt8444)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bbfe31b1-38ce-4ae4-9143-bf08c81617e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f6e9b43-ceca-4a80-9569-696375a6ff5b"}}}], "length": {"value": 0.189207, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "81cb4004-68fb-40b6-a4c6-ce803572effe", "name": "l(r:p1rdt8440-p1rdt8444)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f6e9b43-ceca-4a80-9569-696375a6ff5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "685fbdbf-47af-4cc2-97ce-354dd04ce915"}}}], "length": {"value": 0.10008, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bc9ceca4-f632-4fd8-a6f7-84e549a2d515", "name": "l(r:p1rdt7555-p1rdt8440)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0075333-98fe-4ee8-bb64-a18119b817c0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bbfe31b1-38ce-4ae4-9143-bf08c81617e8"}}}], "length": {"value": 0.34151, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5f52d5ae-c7f7-405d-8cba-6f26dbf641c4", "name": "l(r:p1rdt7555-p1rdt7561)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc6bd64f-1ad3-4bd9-b590-7d4b673a94b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0075333-98fe-4ee8-bb64-a18119b817c0"}}}], "length": {"value": 0.0383631, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a5a9d7da-14d3-472d-9fbc-553a994c3f7b", "name": "l(r:p1rdt7551-p1rdt7561)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f0f3112-1395-48bf-88c1-8dd4b171478d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e068b84-fbff-4546-b708-ca91ffe92b69"}}}], "length": {"value": 0.124844, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0464cff4-421c-4922-a2f6-94dcd83b1534", "name": "l(r:p1rdt7551-p1rdt7561)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e068b84-fbff-4546-b708-ca91ffe92b69"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc6bd64f-1ad3-4bd9-b590-7d4b673a94b5"}}}], "length": {"value": 0.253169, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6d4670f0-7b81-49d7-8d20-f17d1629268c", "name": "l(r:p1rdt7551-p1rdt7574)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1d8c14d0-8247-4a44-98c1-4534aa9037a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f0f3112-1395-48bf-88c1-8dd4b171478d"}}}], "length": {"value": 0.382752, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "02a59a99-c259-48f2-92be-9d6473e77f82", "name": "l(r:p1rdt7553-p1rdt7572)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddf629eb-ea60-4fce-b731-7ebb33665829"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4307e78-304a-4175-8e81-9cb23d99f394"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0148f62b-4c0b-4711-8743-6575577331b4", "name": "l(r:p1rdt7553-p1rdt7574)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f00dd033-8e7c-43af-bd16-1de2954e07be"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7744d8d9-73a8-4274-9c91-5542620942f5"}}}], "length": {"value": 0.0977575, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "36947727-1aa5-4bcc-be37-bdb16a5a0db9", "name": "l(r:p1rdt7553-p1rdt7574)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7744d8d9-73a8-4274-9c91-5542620942f5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddf629eb-ea60-4fce-b731-7ebb33665829"}}}], "length": {"value": 0.0575736, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "14cc1fc7-59d4-4962-adf6-f9a219e7b2be", "name": "l(r:p1rdt5179-p1rdt6273)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9722136-480b-44cb-8b0e-0b3165712688"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d22f1247-b756-4498-8cf8-fef7d1e859ff"}}}], "length": {"value": 0.33969400000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ba35946f-4710-4036-87d9-e90e0fe76bc3", "name": "l(r:p1rdt8408-p1rdt8458)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28af960e-6f27-483a-8029-0c5f1641f51d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "433162b1-2a9b-4187-ba28-ec57503d76f6"}}}], "length": {"value": 0.0888364, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "71ca0f35-18a0-4a56-a50e-ad4f4c9b6f17", "name": "l(r:p1rdt8408-p1rdt8439)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07f340ca-58c2-4331-8265-a39a45c87b75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3430524c-820d-4f17-ba1b-377aeef4bbcd"}}}], "length": {"value": 0.217599, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "21683217-7a15-47db-8cb9-e443f8569fee", "name": "l(r:p1rdt8408-p1rdt8439)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3430524c-820d-4f17-ba1b-377aeef4bbcd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28af960e-6f27-483a-8029-0c5f1641f51d"}}}], "length": {"value": 0.0862144, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3871706d-53bc-4f3c-887c-1b304b0b5bc9", "name": "l(r:p1rdt6278-p1rdt8439)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19d5304c-574f-4646-8095-d2dcbbea86e7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07f340ca-58c2-4331-8265-a39a45c87b75"}}}], "length": {"value": 0.21709300000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6e3a4316-b83a-4df8-a57c-681507b74e08", "name": "l(r:p1rdt8405-p1rdt8445)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8c69243-872f-4e25-9d03-82692bbf8779"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e3ecdca-4b27-4a9d-8599-637924e86602"}}}], "length": {"value": 0.173131, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "99bc096c-88d2-40dc-84bb-74b6f5ee26b3", "name": "l(r:p1rdt8405-p1rdt8445)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e3ecdca-4b27-4a9d-8599-637924e86602"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc0ee90f-1f9e-435e-bac4-86a4688c48fc"}}}], "length": {"value": 0.152596, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "98f7d539-1e7f-40ee-8dda-dcda64bf53e9", "name": "l(r:p1rdt6500-p1rdt6519)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf648a0d-3262-4150-892b-55c3b117050a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5789c3b2-eb91-4e4c-85e8-24f5893e1a2c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1369a137-ea26-496f-a49e-07fe1c36db1c"}}}}, {"uuid": "daedf677-1099-4aa3-b007-b47edc2916ce", "name": "l(r:p1rdt6505-p1rdt6508)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0824c21-244b-4d4e-85d6-238ac4908b5a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb1c1e50-902d-443d-8c9a-b728d2f6b6f1"}}}], "length": {"value": 0.10179900000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d8c829f8-5194-4cb1-81b5-c3a846ffa9d2", "name": "l(r:p1rdt6510-p1rdt6523)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66b7b2e9-7658-4de0-8197-3829c6179353"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "848c04de-e4d5-4520-9dce-0073776c2ae4"}}}], "length": {"value": 0.167854, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "946d1cc9-2f20-4a54-9480-38deb15660e0", "name": "l(r:p1rdt5730-p1rdt9479)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e07d8bc1-2f8a-4067-a2a7-b903dd042ce3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5897bb2-1f72-4aeb-9090-74e2411b5786"}}}], "length": {"value": 0.30509600000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b0df22f1-d622-429d-8f86-7353e33fde28", "name": "l(r:p1rdt5840-p1rdt9479)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7f9286b-4209-402a-a365-1d27da4efb75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35722d90-049e-4c67-9654-acce0572e6c2"}}}], "length": {"value": 0.269952, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "10ffe1dd-0ef5-4c2b-971d-7dd0c7f0540a", "name": "l(r:p1rdt9298-p1rdt9302)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61ba1001-8b9d-481c-b205-45c6e0beadc1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4a41fe9-62ce-45ba-abcd-086ba429baa0"}}}], "length": {"value": 0.0784931, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b6cf13dc-5432-46f6-8ce7-4dcd6142e06d", "name": "l(r:p1rdt9298-p1rdt9310)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3035d22c-c39f-4f07-9fe9-29888b16057d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61ba1001-8b9d-481c-b205-45c6e0beadc1"}}}], "length": {"value": 0.189404, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ddc2c0a9-cf9d-4540-b621-99c53b060d78", "name": "l(r:p1rdt9310-p1rdt9316)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "644c5887-31f1-436c-bbf6-dae5a70743a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3035d22c-c39f-4f07-9fe9-29888b16057d"}}}], "length": {"value": 0.277772, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4617ca55-9b70-443a-912a-2c0b71d2435e", "name": "l(r:p1rdt9312-p1rdt9316)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "644c5887-31f1-436c-bbf6-dae5a70743a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8721684-5439-482c-b8e5-be330d3cf745"}}}], "length": {"value": 0.433834, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c9872dd4-7084-47d2-9b48-0a683d1d5018", "name": "l(r:p1rdt9311-p1rdt9316)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7011f1dc-1e7d-4961-9a23-620b7f5737af"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "644c5887-31f1-436c-bbf6-dae5a70743a2"}}}], "length": {"value": 0.0277071, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e40bd2c2-6249-4777-9efb-9cafe9e9e47b", "name": "l(r:p1rdt6518-p1rdt9311)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95d939ff-e20d-42b3-bb88-f1975f9fa0aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7011f1dc-1e7d-4961-9a23-620b7f5737af"}}}], "length": {"value": 0.103982, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4149df31-d706-455a-9122-9362e3df9b22", "name": "l(r:p1rdt5729-p1rdt5731)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "77d2122b-cbb7-4844-bbb2-55e939431e50"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52f308f4-35db-49ec-a599-f8380489f952"}}}], "length": {"value": 0.353232, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7b3b465f-dd27-42e7-804a-f97d4617ee2f", "name": "l(r:p1rdt5729-p1rdt5731)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52f308f4-35db-49ec-a599-f8380489f952"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95cd61cf-f1cb-4af2-9d3b-e42978642003"}}}], "length": {"value": 0.0107406, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "709aa023-da9c-4e74-80c6-9ac1241821a6", "name": "l(r:p1rdt5728-p1rdt5729)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b55c58cf-153e-4aa3-b099-8a1db05a6ae5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "77d2122b-cbb7-4844-bbb2-55e939431e50"}}}], "length": {"value": 0.125902, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f75bfbb4-dd53-4f91-99e8-d7364ccf82f6", "name": "l(r:p1rdt5728-p1rdt6537)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66ef2ffb-e67d-47eb-ae59-194c538ab861"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b55c58cf-153e-4aa3-b099-8a1db05a6ae5"}}}], "length": {"value": 0.543863, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b25e1279-aaff-4785-8b93-94d78d7a2bed", "name": "l(r:p1rdt6502-p1rdt9468)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b5695dd-714e-4de1-a63a-f142ff0460e1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e6348d4-7fcb-4546-af84-8ece75b6332f"}}}], "length": {"value": 0.434441, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7d206cf2-ecd2-4567-8615-e996c54cd96c", "name": "l(r:p1rdt6501-p1rdt9468)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddfa01c0-4d12-4f96-ab50-0082ef9914a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e4fd2ed-daa1-4a22-936f-8d51ee928d99"}}}], "length": {"value": 0.099806, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bd9d8818-aa67-4354-b9a9-81d0a90330c9", "name": "l(r:p1rdt6509-p1rdt6514)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42f09ae1-037a-4565-9cd2-0187c45b7866"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0737f6ec-0d5d-4cff-b4b7-9910c7076984"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ca790b78-4e94-4ea4-8d32-da938c5aef92", "name": "l(r:p1rdt6498-p1rdt6516)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60b93cd6-c9fc-46ef-8b37-6b14d0773df6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5c5466f-b7e4-4844-967b-9e8b11c68b44"}}}], "length": {"value": 0.0377529, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "34f48699-c9c2-4f8d-8e66-5822d807e169", "name": "l(r:p1rdt7298-p1rdt7313)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1f6ad7d-f7ea-4b94-956c-ec4a3b2028d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b658bf21-450c-4e6b-9dec-c5023a05fd19"}}}], "length": {"value": 0.0390759, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5d3b1a39-3b9f-43d5-a263-b7e274732cb7", "name": "l(r:p1rdt7036-p1rdt7091)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28d17238-8db8-41da-960c-317183423576"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "770cf0ab-50f1-489b-b2ea-d23ba186d10b"}}}], "length": {"value": 0.10505000000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "85f2d27c-47d3-49d1-9a52-3f41ebb66c72", "name": "l(r:p1rdt7036-p1rdt7091)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "770cf0ab-50f1-489b-b2ea-d23ba186d10b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52068090-b613-46d7-a31f-ad3ca26382d5"}}}], "length": {"value": 0.042633, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "81dd9e15-fe70-4d77-bf53-8ac6b6c4d15b", "name": "l(r:p1rdt7620-p1rdt7627)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97be7ac3-a710-4de8-a666-276813582cd6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5bddd75e-1974-41ee-ab51-625c7485a573"}}}], "length": {"value": 0.0237579, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6bdc087e-f95c-4fbe-bfc6-4a0c6270342d", "name": "l(r:p1rdt7311-p1rdt7620)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3a4dfb4-e1b3-43b9-ae42-b0cec47ff4ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97be7ac3-a710-4de8-a666-276813582cd6"}}}], "length": {"value": 0.142725, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ee2d29a7-a257-4805-9145-9257ecfda11e", "name": "l(r:p1rdt7311-p1rdt9473)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3a4dfb4-e1b3-43b9-ae42-b0cec47ff4ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4d8bafa-711d-4fd7-8374-7eeaeb43edcd"}}}], "length": {"value": 0.0811399, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3efc6b05-eb72-4c79-b237-e882fc3d458c", "name": "l(r:p1rdt7306-p1rdt7311)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "607c7275-da9a-4620-b019-59a66e98c2e6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3a4dfb4-e1b3-43b9-ae42-b0cec47ff4ad"}}}], "length": {"value": 0.0813524, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1ddc01b0-2a75-4050-b3a0-41dcad8ecd63", "name": "l(r:p1rdt7306-p1rdt7626)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "607c7275-da9a-4620-b019-59a66e98c2e6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56d67e3e-46af-4e2c-86a8-191d97b0ce8a"}}}], "length": {"value": 0.166342, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ac22d4a7-8ef7-47a3-8567-dbafa8b1ce03", "name": "l(r:p1rdt7302-p1rdt7306)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a65c4d3-2fc6-48c8-b944-68c4229db3dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "607c7275-da9a-4620-b019-59a66e98c2e6"}}}], "length": {"value": 0.183526, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e036c895-092e-4d78-ae61-8e6f09fca24f", "name": "l(r:p1rdt7302-p1rdt7617)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01c9d31d-c3bb-4950-9bbd-00377c252ddc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a65c4d3-2fc6-48c8-b944-68c4229db3dd"}}}], "length": {"value": 0.047802300000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "70140404-3f92-4e1f-a77d-b86b6a9a60d5", "name": "l(r:p1rdt7617-p1rdt7625)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a11cf3d9-90bb-4de8-b637-6ec9128525ec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01c9d31d-c3bb-4950-9bbd-00377c252ddc"}}}], "length": {"value": 0.0218023, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1f189dee-08e4-4079-bab5-e8a21d66de1f", "name": "l(r:p1rdt7616-p1rdt7630)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "723e2b5c-414c-4f3d-ba23-d2df4bc63e75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7167a2e-9e83-441e-a15b-0256848c3f6d"}}}], "length": {"value": 0.140205, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "fa7dc0a1-b720-42aa-93aa-5e53edf78be1", "name": "l(r:p1rdt7621-p1rdt7630)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa48cf27-3b07-4460-ad9c-8d9862238645"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "723e2b5c-414c-4f3d-ba23-d2df4bc63e75"}}}], "length": {"value": 0.0539367, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c2ab22f8-e100-4ef0-89b3-a41bcc8ad74f", "name": "l(r:p1rdt7621-p1rdt7625)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53df7b6e-bd8c-43f2-860d-8869aec5d079"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa48cf27-3b07-4460-ad9c-8d9862238645"}}}], "length": {"value": 0.18848800000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "771f897b-1f10-40db-b3d7-4066cc1d7638", "name": "l(r:p1rdt7054-p1rdt7090)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08d3a02a-555d-4ad1-9b13-d413b7a16eef"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3cf406b-69e6-4aee-a6fc-272dad7693a4"}}}], "length": {"value": 0.0578677, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "31498136-0f28-4bd8-98f5-9acb29e9649c", "name": "l(r:p1rdt7069-p1rdt7090)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aae22557-7d34-401d-82c9-2d2710ff2915"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08d3a02a-555d-4ad1-9b13-d413b7a16eef"}}}], "length": {"value": 0.128791, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "cdee7d08-5c71-4bf8-a182-b3c06db81686", "name": "l(r:p1rdt7069-p1rdt7087)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f614382d-3883-4f6b-b1f6-c8e83d84ee22"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aae22557-7d34-401d-82c9-2d2710ff2915"}}}], "length": {"value": 0.09476340000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d3bca9dc-c799-419f-9d47-eeac6c2ed7df", "name": "l(r:p1rdt7075-p1rdt7087)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8cebb186-4d9e-4d2c-b0d9-100056d34942"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f614382d-3883-4f6b-b1f6-c8e83d84ee22"}}}], "length": {"value": 0.198314, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1ee5dd7f-8852-4cb7-a544-f046413b4410", "name": "l(r:p1rdt7075-p1rdt7080)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "662e2a1c-9a54-4ac3-b478-98e3a478349d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8cebb186-4d9e-4d2c-b0d9-100056d34942"}}}], "length": {"value": 0.127901, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "389f514c-fe23-4cce-aa69-67e8571eb690", "name": "l(r:p1rdt7080-p1rdt7619)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "161d6f3b-8bd9-4fa8-9442-c6ff008e8d3d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "662e2a1c-9a54-4ac3-b478-98e3a478349d"}}}], "length": {"value": 0.059386400000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4cf5b365-3f96-468a-aeb9-3dcdf312110b", "name": "l(r:p1rdt7615-p1rdt7619)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "161d6f3b-8bd9-4fa8-9442-c6ff008e8d3d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "105df8ff-ec38-4cd6-b557-c318b4023bd0"}}}], "length": {"value": 0.217966, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3231a082-6540-4f71-a015-260c8614cb63", "name": "l(r:p1rdt7619-p1rdt7631)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9e53141-a773-4127-9558-3887070a8f36"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "161d6f3b-8bd9-4fa8-9442-c6ff008e8d3d"}}}], "length": {"value": 0.0570511, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4cc17ad4-3478-4c0c-8565-3dcaeb133743", "name": "l(r:p1rdt7625-p1rdt7631)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "460f5de9-8d4f-468a-b67a-b3b05354a9ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9e53141-a773-4127-9558-3887070a8f36"}}}], "length": {"value": 0.204577, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f8db6b2e-8307-43f8-a986-8c951fc06e7c", "name": "l(r:p1rdt6515-p1rdt6535)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fec078c2-a5d8-4317-a8ac-bc25772f6358"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5a05d0e-8cf2-4ab8-bdfd-24b8cd12ad67"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1369a137-ea26-496f-a49e-07fe1c36db1c"}}}}, {"uuid": "fcee0ed8-6baf-4eef-b433-a2ba9085968a", "name": "l(r:p1rdt6515-p1rdt6536)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04c1e05a-9cbb-4e53-9412-1cffd3976bed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5aa6899b-19a2-41e6-b445-f9fe2536c8d9"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1369a137-ea26-496f-a49e-07fe1c36db1c"}}}}, {"uuid": "16950521-fdd9-46ba-b9eb-d9f5b812710e", "name": "l(r:p1rdt8901-p1rdt8902)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d21061fa-1011-44f7-8a20-26fcf0550f52"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f23ab51c-56f3-4421-b66e-7cdcf109787d"}}}], "length": {"value": 0.309301, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b24e98ec-fd06-44e5-becf-6da45152feab", "name": "l(r:p1rdt7301-p1rdt9377)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61972a50-ce24-4ec1-8535-402665b55a55"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84200441-4c26-4966-a4b7-6b91fb43f02e"}}}], "length": {"value": 0.355831, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "33c4c723-7618-4494-9cf7-a8a01746a442", "name": "l(r:p1rdt8902-p1rdt9377)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43c862de-b014-4b24-8b34-54dae6edcf5a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32e86968-974e-4bcc-b562-1d4209771cf0"}}}], "length": {"value": 0.172034, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "04c8a47f-0b2d-4b5d-af7e-6361e20360cb", "name": "l(r:p1rdt8490-p1rdt9463)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37c41a4b-e439-42a1-b9a7-0582c528f0e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "271ab023-4425-40d8-8080-2481c71309b5"}}}], "length": {"value": 0.21351000000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "83e505b0-a9d8-4e85-ba9c-50cf7624af58", "name": "l(r:p1rdt8490-p1rdt8492)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "307d9c6d-d5ee-4490-95d3-5a9b1d171e54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37c41a4b-e439-42a1-b9a7-0582c528f0e5"}}}], "length": {"value": 0.0991871, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e2567550-8f85-4d77-96b7-a3ef3a0089e0", "name": "l(r:p1rdt7599-p1rdt8492)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "605c34bc-3f7c-4eb7-8df0-fcd00d261921"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3833996b-287c-4a13-9e7c-6834047f3691"}}}], "length": {"value": 1.29606, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5a80d1ee-2c0b-4cff-80ee-f9a438a10bca", "name": "l(r:p1rdt7599-p1rdt8492)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3833996b-287c-4a13-9e7c-6834047f3691"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "307d9c6d-d5ee-4490-95d3-5a9b1d171e54"}}}], "length": {"value": 2.04702, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7d48cc0e-c882-49ae-be92-fe816aa16373", "name": "l(r:p1rdt6226-p1rdt9333)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f6d3fab-3b83-40c9-85c4-cfeddd0d317a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76f24b35-1b82-4760-9817-80c166073f37"}}}], "length": {"value": 0.0994771, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6f3ebb5c-96d5-480e-8403-d35921fdeaae", "name": "l(r:p1rdt6226-p1rdt9333)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76f24b35-1b82-4760-9817-80c166073f37"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d81fc6d7-3400-41d4-91d7-b350d7def98d"}}}], "length": {"value": 0.117787, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5b73908d-2f28-48e9-a7e7-aa024cdccfc5", "name": "l(r:p1rdt5650-p1rdt5662)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36c3c493-ff68-4bb8-a3f4-043c5f847bd3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8f1c67e-9e29-45a3-a2a3-c2f3493a6898"}}}], "length": {"value": 0.373528, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bf809203-3662-4e57-8041-984c2164057f", "name": "l(r:p1rdt5658-p1rdt5663)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81f0e00e-bc49-448a-8e69-0569ed6a8c1a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67d07fb-aec5-4120-8254-32bfcd91e378"}}}], "length": {"value": 0.167002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "83ab7e51-98a6-4e95-b5fa-6c9c2095e331", "name": "l(r:p1rdt5658-p1rdt5663)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67d07fb-aec5-4120-8254-32bfcd91e378"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7356d982-36fd-46cb-9300-8889502e8dc8"}}}], "length": {"value": 0.0344971, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d376dca1-f218-4215-bdc9-4841f949ab27", "name": "l(r:p1rdt7046-p1rdt7067)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b470fa62-70d4-4cc5-8f7e-b9cda37481e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9bb8596a-bcb2-4282-bf1b-9939a9af87d9"}}}], "length": {"value": 0.207649, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "394c4f8d-a10c-4cc7-8d1b-605bc435f8b5", "name": "l(r:p1rdt7038-p1rdt7067)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb3a9847-70d0-4004-95ef-63884c6c1cdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b470fa62-70d4-4cc5-8f7e-b9cda37481e0"}}}], "length": {"value": 0.160885, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5af024a4-176d-4d88-92aa-1cce7304ee2e", "name": "l(r:p1rdt7038-p1rdt7070)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac6e8ccf-75ec-42e0-a3cb-9ab86e2731a4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9cb2d8d-1991-463c-9e6b-88f5624f28c3"}}}], "length": {"value": 0.0923408, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "26068bfb-36ee-4ac3-959b-e22ca0508ad2", "name": "l(r:p1rdt7038-p1rdt7070)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9cb2d8d-1991-463c-9e6b-88f5624f28c3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb3a9847-70d0-4004-95ef-63884c6c1cdc"}}}], "length": {"value": 0.238971, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a443312f-ca47-446d-960f-3de76a23b1f2", "name": "l(r:p1rdt9381-p1rdt9396)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a597011-5e60-46fe-90d6-85728ff0ffa3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5791345-57dc-4f54-ab54-ea63e6a54ee0"}}}], "length": {"value": 0.139587, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bcb59ecd-71f2-4a91-9918-2f6cfe394c47", "name": "l(r:p1rdt7088-p1rdt9396)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac70c13b-5f4f-45f3-880a-b4b476ea552a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a597011-5e60-46fe-90d6-85728ff0ffa3"}}}], "length": {"value": 0.16851400000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f066d9af-3a31-4e4e-9df6-3876ea0e5186", "name": "l(r:p1rdt7088-p1rdt7089)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31cd4834-477f-4060-8efd-0504c8e8eaa9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac70c13b-5f4f-45f3-880a-b4b476ea552a"}}}], "length": {"value": 0.07985440000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "08efaac7-6d95-4425-a194-e9fd5edb3d32", "name": "l(r:p1rdt7061-p1rdt7089)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75947ffd-3765-443b-bef8-b6af746ef624"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "324f5d62-9feb-4fe4-bc1b-3dcf01898148"}}}], "length": {"value": 0.135079, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1a1b0973-d4c6-47d7-8d97-e21a08b578a2", "name": "l(r:p1rdt7061-p1rdt7089)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "324f5d62-9feb-4fe4-bc1b-3dcf01898148"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31cd4834-477f-4060-8efd-0504c8e8eaa9"}}}], "length": {"value": 0.18246, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "552b8434-b608-4927-a5b9-ea068ccdc34d", "name": "l(r:p1rdt7061-p1rdt7070)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac6e8ccf-75ec-42e0-a3cb-9ab86e2731a4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84578de8-d5de-41fe-b637-42425e97b7db"}}}], "length": {"value": 0.128507, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3459416c-f085-4e60-9593-ce3b3585f76c", "name": "l(r:p1rdt7061-p1rdt7070)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84578de8-d5de-41fe-b637-42425e97b7db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75947ffd-3765-443b-bef8-b6af746ef624"}}}], "length": {"value": 0.322501, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a1c26b2c-7b4a-4027-88a6-1cbb94147d65", "name": "l(r:p1rdt5658-p1rdt7070)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02407b52-58c3-403c-9b5b-38695f435476"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac6e8ccf-75ec-42e0-a3cb-9ab86e2731a4"}}}], "length": {"value": 0.61978, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4c909e74-bd70-48ae-b4b9-fa6c0f49c742", "name": "l(r:p1rdt5017-p1rdt5200)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0843e99-e917-473c-bec7-ee0c3ddec601"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "799ab435-c0a4-4515-8125-e8ca2fb7632d"}}}], "length": {"value": 0.234989, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3904e139-a874-4ec4-b65c-f1113096a4b4", "name": "l(r:p1rdt7576-p1rdt8422)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b28595b-dcbe-4d1b-92c4-94acf370bb1f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ce65512-7d5f-4514-b55c-1775e80dd94d"}}}], "length": {"value": 0.0564986, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "91556012-ddc5-4cf8-828a-a6303f5cb1bd", "name": "l(r:p1rdt7576-p1rdt8151)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a31fa2-4df8-418a-a215-d0d450ced9a3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df71ab4b-258c-4812-9537-6d425bacb468"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "96c8992e-ab08-485e-8757-96b0e71fedc8", "name": "l(r:p1rdt7576-p1rdt8151)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df71ab4b-258c-4812-9537-6d425bacb468"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c951cf67-3297-407f-805c-55d9c03fb519"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "75782f97-8d8e-4957-97f0-8e2dabe321d9", "name": "l(r:p1rdt7576-p1rdt8151)_s2", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c951cf67-3297-407f-805c-55d9c03fb519"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b28595b-dcbe-4d1b-92c4-94acf370bb1f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7c6ac7b6-d8d7-455b-817c-4553072e5c9a", "name": "l(r:p1rdt8149-p1rdt8155)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1613a53e-5194-4d26-b83b-475d9f02a32c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b706c56-20f1-49ed-9cbe-0ec1491b83e0"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "40a5a234-9d35-48aa-8436-976911dc216f", "name": "l(r:p1rdt5153-p1rdt8441)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b423745-cc70-4c3a-adb0-f648170b4ab1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dac2cb8c-428b-49c4-8368-35608c050390"}}}], "length": {"value": 0.190536, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "cf871f54-cd17-4e6e-b56a-680cb64f1680", "name": "l(r:p1rdt5153-p1rdt8441)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dac2cb8c-428b-49c4-8368-35608c050390"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dff898c1-a386-4219-9e8d-2d08b49f9098"}}}], "length": {"value": 0.26071, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b28e3e27-9c0e-4a4e-89c9-565fdc854f99", "name": "l(r:p1rdt5153-p1rdt8441)_s2", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dff898c1-a386-4219-9e8d-2d08b49f9098"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb8dae66-287a-4b8a-9cda-6ae02cb8f8a9"}}}], "length": {"value": 0.128532, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "21a471ec-3f91-4bac-9f9c-2f63f39e7608", "name": "l(r:p1rdt8150-p1rdt8441)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78081763-07d2-4989-b492-e1c5178c4097"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83b76782-be09-4733-a35c-6f3f26059a4d"}}}], "length": {"value": 0.16747, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "59606c40-3050-4e1f-84d7-b3adeab006eb", "name": "l(r:p1rdt8150-p1rdt8441)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83b76782-be09-4733-a35c-6f3f26059a4d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b423745-cc70-4c3a-adb0-f648170b4ab1"}}}], "length": {"value": 0.585344, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9390eaa1-85ed-427d-b557-87485f68297d", "name": "l(r:p1rdt8150-p1rdt8442)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78081763-07d2-4989-b492-e1c5178c4097"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2ef098d-d7e6-4530-a5cc-b6472ec9ffdc"}}}], "length": {"value": 0.219381, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ae6dfad9-4b8b-4567-beea-e08350b422f2", "name": "l(r:p1rdt8150-p1rdt8442)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2ef098d-d7e6-4530-a5cc-b6472ec9ffdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6700763-e6dc-4626-ac2b-22985f0043be"}}}], "length": {"value": 0.29839800000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9914a6ee-984e-4689-83bb-a541dd092fc7", "name": "l(r:p1rdt8150-p1rdt8155)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1613a53e-5194-4d26-b83b-475d9f02a32c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b7280d1f-5ff9-45ee-9949-ecc70509a2a1"}}}], "length": {"value": 0.0723619, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "deed0a14-e67a-4500-9626-be034c9a20fa", "name": "l(r:p1rdt8150-p1rdt8155)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b7280d1f-5ff9-45ee-9949-ecc70509a2a1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78081763-07d2-4989-b492-e1c5178c4097"}}}], "length": {"value": 0.0446835, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8f14f92d-f5a4-4941-a518-79a7131e3bdd", "name": "l(r:p1rdt8155-p1rdt8157)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1613a53e-5194-4d26-b83b-475d9f02a32c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a30e197-897f-4516-b4e5-f70081e6f8c7"}}}], "length": {"value": 0.11694, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c9ae81de-99a7-45de-8eae-0dc8d72eb86c", "name": "l(r:p1rdt8151-p1rdt8155)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0a6628e-afc1-4daf-8a29-7626ac2aa5dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1613a53e-5194-4d26-b83b-475d9f02a32c"}}}], "length": {"value": 0.09203890000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "17a9aea4-714b-4a9e-bc93-6d59c828ea03", "name": "l(r:p1rdt5481-p1rdt5483)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f903015c-95a7-4d6e-b2a5-e9705c050c6e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d29d8b74-a24d-4474-9752-c1ffa1aa7f7c"}}}], "length": {"value": 0.218893, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bc927f95-acf8-4e59-9de3-a63c5a83649d", "name": "l(r:p1rdt5480-p1rdt5483)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2568f11c-8a37-4a55-8bce-9f0d56ac386a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f903015c-95a7-4d6e-b2a5-e9705c050c6e"}}}], "length": {"value": 0.0194577, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "dcc2039e-e644-4d69-b245-4b2970b5781d", "name": "l(r:p1rdt5477-p1rdt5480)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7d7f462-1ab5-4fd8-baaa-7e576eead5c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2568f11c-8a37-4a55-8bce-9f0d56ac386a"}}}], "length": {"value": 0.05838600000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "16f55ad7-24d9-4ec0-8729-a3f0c865164a", "name": "l(r:p1rdt5477-p1rdt7201)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7d7f462-1ab5-4fd8-baaa-7e576eead5c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df1d5615-4a0b-4041-8940-f13de9f7036a"}}}], "length": {"value": 0.101327, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "cb4e31da-15dd-4846-95b9-04865a0bcc59", "name": "l(r:p1rdt5477-p1rdt7201)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df1d5615-4a0b-4041-8940-f13de9f7036a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f64ed4a2-6afb-447c-8c6b-15935e050a6d"}}}], "length": {"value": 0.0635197, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1e1f4f6c-9c9c-4c7c-afa2-84cde862974f", "name": "l(r:p1rdt5472-p1rdt5477)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a8c3f7f-b9be-4c5e-b6f0-8f2fc18935fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "595463a5-2019-4c94-b72d-c824c2aef347"}}}], "length": {"value": 0.182509, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "436ac0bd-b246-48ce-94e1-7b1b0df0c7c7", "name": "l(r:p1rdt5472-p1rdt5477)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "595463a5-2019-4c94-b72d-c824c2aef347"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7d7f462-1ab5-4fd8-baaa-7e576eead5c7"}}}], "length": {"value": 0.00190877, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c20d723c-25d6-4888-b6f4-97cc3e392f79", "name": "l(r:p1rdt5472-p1rdt5476)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d69527e6-70b6-43e2-8b9e-7c8570ad5ddf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a8c3f7f-b9be-4c5e-b6f0-8f2fc18935fa"}}}], "length": {"value": 0.464713, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ac8991d3-6d78-4983-999e-61a1df7121c2", "name": "l(r:p1rdt7704-p1rdt9266)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02ea9067-6a2a-48b6-b5f1-10992b9fbd77"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f633393e-4d67-4646-838b-14f25641b426"}}}], "length": {"value": 0.327122, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "63d17b30-daf0-4906-8098-2e394c28e221", "name": "l(r:p1rdt7704-p1rdt9266)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f633393e-4d67-4646-838b-14f25641b426"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fbb2bd0-d109-4248-85f3-266fe479677f"}}}], "length": {"value": 0.119759, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "91bc4b46-c695-480b-858f-4fb349c9f026", "name": "l(r:p1rdt7704-p1rdt7712)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4462b9c6-748f-48e9-9ff9-7f20a06cf456"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02ea9067-6a2a-48b6-b5f1-10992b9fbd77"}}}], "length": {"value": 0.290826, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "74871719-24e2-4446-a5c1-6607bc9b6bd2", "name": "l(r:p1rdt7712-p1rdt7718)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4462b9c6-748f-48e9-9ff9-7f20a06cf456"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "048e2bab-67f2-4975-81a1-bbc9f2f9cd88"}}}], "length": {"value": 0.315016, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8fb5ae90-d852-4217-8ad8-7e35ff1771ef", "name": "l(r:p1rdt7701-p1rdt7712)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "74968ebc-53c5-4fc6-8172-3ffa9dea7683"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4462b9c6-748f-48e9-9ff9-7f20a06cf456"}}}], "length": {"value": 0.0526994, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "764fe5e3-4f60-49ac-b40e-80e11eef2a63", "name": "l(r:p1rdt7699-p1rdt7701)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec849ee4-3d69-46a9-9a2a-242a3943e46c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "74968ebc-53c5-4fc6-8172-3ffa9dea7683"}}}], "length": {"value": 0.0894152, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "948e03e5-6f8e-4e2a-b745-53bc7ae9fb10", "name": "l(r:p1rdt5485-p1rdt7699)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cfb3a23-3a93-4d89-8b70-e4730ebbce1a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "890cd47a-994b-4dca-8d59-25164f04c927"}}}], "length": {"value": 0.126204, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "432a59ab-ea4f-45fb-b79f-173e74a857ab", "name": "l(r:p1rdt5485-p1rdt7699)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "890cd47a-994b-4dca-8d59-25164f04c927"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec849ee4-3d69-46a9-9a2a-242a3943e46c"}}}], "length": {"value": 0.179947, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e51e0264-f754-45e2-a1b3-933e30c3cd56", "name": "l(r:p1rdt5475-p1rdt5485)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b9e57e0-6dc8-4831-ac7d-36f8608b7a8d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cfb3a23-3a93-4d89-8b70-e4730ebbce1a"}}}], "length": {"value": 0.0575139, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ecfbc31a-21c6-47a5-a744-7345eb49ee1e", "name": "l(r:p1rdt5475-p1rdt5476)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae343ca3-3337-4528-b117-38a51e6d023f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b9e57e0-6dc8-4831-ac7d-36f8608b7a8d"}}}], "length": {"value": 0.453804, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0dfee531-83f3-4357-8062-4451c875f683", "name": "l(r:p1rdt5476-p1rdt5478)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c977e6c-43f0-4d7e-b19f-82f0de97dab2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a97491e-2c98-4584-9b74-5593f17faeda"}}}], "length": {"value": 0.3849, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "63f4017a-0e53-4030-9f03-15546872260d", "name": "l(r:p1rdt6848-p1rdt9264)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96399e51-1243-4e7f-ae3a-5e2c67123aae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b764d22-debb-4d88-8221-ff79307e609f"}}}], "length": {"value": 0.24693, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "62ef9b36-dcd1-4bc0-907a-675b87e52164", "name": "l(r:p1rdt6848-p1rdt9264)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b764d22-debb-4d88-8221-ff79307e609f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bdf3994-bb0c-44f4-b1ea-ab29e73bd39c"}}}], "length": {"value": 0.116892, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3b953a51-c8a1-4a38-8773-f8a7016dfcbf", "name": "l(r:p1rdt6847-p1rdt6848)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e92b102-eaee-41cc-a2fc-c6c4b3bfb58b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "96399e51-1243-4e7f-ae3a-5e2c67123aae"}}}], "length": {"value": 0.92611, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "480f3768-51e4-48e1-a449-a533eb206658", "name": "l(r:p1rdt6847-p1rdt7624)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be9350ab-7ad2-4a89-a374-94bf69588d7f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e92b102-eaee-41cc-a2fc-c6c4b3bfb58b"}}}], "length": {"value": 0.622643, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "2792a58e-fa63-427d-950f-9719c7fa27ea", "name": "l(r:p1rdt6348-p1rdt6350)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d6c5b78-35c4-475a-8837-776dea236c95"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c935f1c0-e36c-407d-a2e8-4181c4b0733e"}}}], "length": {"value": 0.150337, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bdb40655-4f94-4583-af63-540676cc787b", "name": "l(r:p1rdt6345-p1rdt6348)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40280da5-767c-4610-b6a8-ff411e1c33e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d6c5b78-35c4-475a-8837-776dea236c95"}}}], "length": {"value": 0.368527, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "50411b97-2ca0-4fd4-a03d-cd1d5a15d841", "name": "l(r:p1rdt6345-p1rdt6356)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1bdfc1ac-98a4-43dd-bb2c-837d0a2c15f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40280da5-767c-4610-b6a8-ff411e1c33e8"}}}], "length": {"value": 0.463971, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9944e15d-1d1f-4de2-b2d7-73810d8a552e", "name": "l(r:p1rdt6353-p1rdt6356)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1bdfc1ac-98a4-43dd-bb2c-837d0a2c15f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e51e0d9-24b6-40ac-859a-51ea74c93e76"}}}], "length": {"value": 0.407215, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "73284547-7d9c-4518-b0b1-abc15099090f", "name": "l(r:p1rdt6354-p1rdt6356)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1bdfc1ac-98a4-43dd-bb2c-837d0a2c15f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2040b1a2-85bc-405a-9dab-138561b5e3ac"}}}], "length": {"value": 0.108189, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6396a12f-73d3-4220-acb6-ffb04d2fd93a", "name": "l(r:p1rdt6354-p1rdt6356)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2040b1a2-85bc-405a-9dab-138561b5e3ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a05e7c9-4bff-46fd-b356-8120b481b053"}}}], "length": {"value": 0.017765, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d633367e-1657-4af7-9dfa-e9d06c37122b", "name": "l(r:p1rdt6347-p1rdt6356)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7166849-6ecd-4270-bf52-d0579838336a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1bdfc1ac-98a4-43dd-bb2c-837d0a2c15f9"}}}], "length": {"value": 0.633788, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5911af5d-66da-477a-9570-565ddc5292fb", "name": "l(r:p1rdt7598-p1rdt7605)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e36f1f1-6993-46b0-bafa-9530fd1652ef"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f95e5fa5-a84c-42a4-b519-8d344e816ecd"}}}], "length": {"value": 0.10583000000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "dd01fae1-634b-400c-a135-5dd7242a7e81", "name": "l(r:p1rdt7589-p1rdt7605)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f9809eb-41e0-40a8-b43a-93556f767f68"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e36f1f1-6993-46b0-bafa-9530fd1652ef"}}}], "length": {"value": 0.43683900000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1441ec02-dff2-4e01-af50-3ee3779998cb", "name": "l(r:p1rdt7589-p1rdt7612)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f9809eb-41e0-40a8-b43a-93556f767f68"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3410d88a-3e9c-427e-a79e-5c602455ed1d"}}}], "length": {"value": 0.525437, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "58ab57ef-9ed9-40ab-a4a0-72c5c4f3b6f6", "name": "l(r:p1rdt6347-p1rdt7589)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7166849-6ecd-4270-bf52-d0579838336a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f9809eb-41e0-40a8-b43a-93556f767f68"}}}], "length": {"value": 0.816381, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d601e0c8-87fa-4c4d-91e4-db629622c5ab", "name": "l(r:p1rdt6347-p1rdt8470)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6163371c-55ef-4900-a3ef-2e4e8fc2894a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7166849-6ecd-4270-bf52-d0579838336a"}}}], "length": {"value": 1.6455, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f9d802d6-7774-4bcd-92c8-41fed7e7cdec", "name": "l(r:p1rdt5218-p1rdt5653)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "769c14db-ac3f-438d-9f7d-c7eb2d3074b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98f2c16a-cdbd-49a3-b60d-4be6e9158480"}}}], "length": {"value": 0.123439, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ebc30854-15d0-4059-a4e4-a3b1a8071a39", "name": "l(r:p1rdt5218-p1rdt5653)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98f2c16a-cdbd-49a3-b60d-4be6e9158480"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dda7f7c-3b21-46a0-88a3-2b7f028b7772"}}}], "length": {"value": 0.122523, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4714a056-deff-4fcb-be44-1619b12bc118", "name": "l(r:p1rdt5195-p1rdt5653)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58c6d858-d457-4fe6-a45b-b9b2b73cad8c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fbc486eb-4f08-4602-a101-1298d4a46b32"}}}], "length": {"value": 0.10076600000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "242b9fb2-b832-46a9-b745-db7185470528", "name": "l(r:p1rdt6995-p1rdt7015)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3741c9d4-d03a-4b2f-be57-52a8977351ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d4d11a9-8de3-4dbe-8974-6005ed40f363"}}}], "length": {"value": 0.232606, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "699b5de4-087d-4717-9489-fb69e110294a", "name": "l(r:p1rdt6995-p1rdt7015)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d4d11a9-8de3-4dbe-8974-6005ed40f363"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6278a0d-f5d3-4b11-aee9-3bb23f9954a8"}}}], "length": {"value": 0.0860291, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f53d6c08-324f-49c9-9c3e-83864f308dc5", "name": "l(r:p1rdt16638-p1rdt16725)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c0d417e-c787-4b0a-a39e-b19ef274b36b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2d0eb0b-bbb6-4b3e-bdc6-4c8a0e7d466f"}}}], "length": {"value": 0.163486, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "176d8831-9ba5-4d7b-865b-99ea7e6aa381", "name": "l(r:p1rdt16638-p1rdt6995)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3741c9d4-d03a-4b2f-be57-52a8977351ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddb8e50b-2619-4e74-aee6-84dc4e11389e"}}}], "length": {"value": 0.166099, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b817c266-305b-4ad6-afa6-cdbd5b7def69", "name": "l(r:p1rdt16638-p1rdt6995)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddb8e50b-2619-4e74-aee6-84dc4e11389e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c0d417e-c787-4b0a-a39e-b19ef274b36b"}}}], "length": {"value": 4.23424, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "045afc0b-2012-4ca8-a295-71783d57d765", "name": "l(r:p1rdt5195-p1rdt6995)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58c6d858-d457-4fe6-a45b-b9b2b73cad8c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9056795d-5c81-4fb9-96bc-51d63b32b187"}}}], "length": {"value": 0.168784, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6a994cb4-f5f1-4df2-8d5e-c05435989755", "name": "l(r:p1rdt5195-p1rdt6995)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9056795d-5c81-4fb9-96bc-51d63b32b187"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3741c9d4-d03a-4b2f-be57-52a8977351ad"}}}], "length": {"value": 0.659388, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5c99986b-343d-4b8d-beb5-8d646498648b", "name": "l(r:p1rdt5195-p1rdt5202)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "227d848c-cddc-4561-996b-f8f7a60a5a89"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43e1b69a-c6dd-447e-82d9-921998de9837"}}}], "length": {"value": 0.168993, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bce828da-59ac-4d79-a897-197182228522", "name": "l(r:p1rdt5195-p1rdt5202)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43e1b69a-c6dd-447e-82d9-921998de9837"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e2f2704-4dee-4c78-b199-256b907156f3"}}}], "length": {"value": 0.111644, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "459455e3-ceff-404b-b7ce-cf80495c6db9", "name": "l(r:p1rdt5195-p1rdt5202)_s2", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e2f2704-4dee-4c78-b199-256b907156f3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58c6d858-d457-4fe6-a45b-b9b2b73cad8c"}}}], "length": {"value": 0.284889, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "14d0c4b1-b98e-469a-a68c-82291e282126", "name": "l(r:p1rdt5202-p1rdt5206)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97e4f179-9d60-4183-8326-eb0ab98a53eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17fedb14-6008-43fd-b7e9-342a113f27a6"}}}], "length": {"value": 0.19259500000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5b4278e7-9191-458b-b6c3-fcf736f69eaa", "name": "l(r:p1rdt5202-p1rdt5206)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17fedb14-6008-43fd-b7e9-342a113f27a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ed081eb-6b56-43b8-9cf8-e7ffdd8222f2"}}}], "length": {"value": 0.0669161, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "45ad7777-5030-4f58-baee-e3f8ffdcaa71", "name": "l(r:p1rdt5202-p1rdt7268)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a21680f1-33a7-44e1-9293-98c6861ba2a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6e61d2f-f75e-4335-aec9-4722942be9f1"}}}], "length": {"value": 0.301796, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5edc97b2-39e7-4ad3-89c4-4701b2b65678", "name": "l(r:p1rdt5202-p1rdt7268)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6e61d2f-f75e-4335-aec9-4722942be9f1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97e4f179-9d60-4183-8326-eb0ab98a53eb"}}}], "length": {"value": 1.26696, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7dcb8149-48f5-40b6-8bf7-d2a9a285cc09", "name": "l(r:p1rdt6349-p1rdt6355)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "88cc1382-6b14-4500-8a21-662fce6a0c0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c1edcfa-e0e4-4493-a9bb-e6033185ce67"}}}], "length": {"value": 0.0974401, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e157dc9b-2c86-419e-b934-ef99e273990b", "name": "l(r:p1rdt6355-p1rdt7224)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eeab7dfa-540c-4275-b159-f6ac4d1350f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "88cc1382-6b14-4500-8a21-662fce6a0c0b"}}}], "length": {"value": 0.455366, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4cbbff52-c85f-4eb7-b673-68e04d17547b", "name": "l(r:p1rdt7224-p1rdt7618)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eeab7dfa-540c-4275-b159-f6ac4d1350f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0fef9b3-a4bd-421c-8a54-cbf6f44c460d"}}}], "length": {"value": 0.282912, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d47ed6f4-4d52-4f70-a3e9-8fc6abdfb2c8", "name": "l(r:p1rdt7224-p1rdt7268)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a21680f1-33a7-44e1-9293-98c6861ba2a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22978d10-c9dc-4c84-8025-5749c730daa6"}}}], "length": {"value": 0.593134, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "2804c4ab-653b-4383-9793-17d37549fd78", "name": "l(r:p1rdt7224-p1rdt7268)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22978d10-c9dc-4c84-8025-5749c730daa6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eeab7dfa-540c-4275-b159-f6ac4d1350f9"}}}], "length": {"value": 0.197971, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c8da4fda-f3b6-4e5e-80ad-e99478be3bf2", "name": "l(r:p1rdt7268-p1rdt8470)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6225b33-2abc-4f77-9d65-459794f56353"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a21680f1-33a7-44e1-9293-98c6861ba2a5"}}}], "length": {"value": 1.40851, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8da487d2-4b45-4418-bfbc-c0dea1344931", "name": "l(r:p1rdt7735-p1rdt7790)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97198258-8ba3-4950-8747-3241c6a4fcee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62078787-3ae2-47b3-8f67-8e89e110c8be"}}}], "length": {"value": 0.206801, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f413d80b-c84b-4b47-b903-13ba7aaeb14e", "name": "l(r:p1rdt7790-p1rdt9090)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15a7847f-aa96-4206-b4c6-422802f4e0a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97198258-8ba3-4950-8747-3241c6a4fcee"}}}], "length": {"value": 0.246196, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "280746d1-8633-4f46-b5b2-5c3366afa2a9", "name": "l(r:p1rdt8911-p1rdt9384)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26613f51-86bf-4ae1-86c0-f23e48cf606e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7bc7d623-3ca7-4c4e-b11c-f373e90d06b6"}}}], "length": {"value": 0.11493, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4ea02402-fbd7-4f93-a5b3-87c7cba41c90", "name": "l(r:p1rdt8911-p1rdt9384)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7bc7d623-3ca7-4c4e-b11c-f373e90d06b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6eb9c7a5-5ab1-4d9b-a59e-538b68ad0bb9"}}}], "length": {"value": 0.0369839, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "76520eb4-9022-455a-95e2-68615f432757", "name": "l(r:p1rdt8905-p1rdt8911)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "924fc042-6ddc-484b-b09f-c65b35817d25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26613f51-86bf-4ae1-86c0-f23e48cf606e"}}}], "length": {"value": 0.148702, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "fe8ce15c-6fbe-4020-8e5d-d64427fd1c55", "name": "l(r:p1rdt8904-p1rdt8916)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "adcc33f8-72a3-434c-a021-6c5973713a91"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5584edfb-c31e-4e1d-87d3-b8161a59b15b"}}}], "length": {"value": 0.119301, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f35e4490-62b3-46a0-bb93-7194613325c6", "name": "l(r:p1rdt8904-p1rdt8916)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5584edfb-c31e-4e1d-87d3-b8161a59b15b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2edd17c2-6dfb-4f86-8998-b90a99755e96"}}}], "length": {"value": 0.0388388, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0d648254-33db-4f6c-b1a3-a5eb565882e2", "name": "l(r:p1rdt8905-p1rdt8916)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "924fc042-6ddc-484b-b09f-c65b35817d25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "adcc33f8-72a3-434c-a021-6c5973713a91"}}}], "length": {"value": 0.1748, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1f0641a1-24a2-44f6-a540-19f1d775a311", "name": "l(r:p1rdt8905-p1rdt8915)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "361385c6-bb6d-4bbc-ab7d-4a5774e03d82"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "924fc042-6ddc-484b-b09f-c65b35817d25"}}}], "length": {"value": 0.0903932, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "02e7d66a-a59b-4e2b-a49f-babf0eed8b45", "name": "l(r:p1rdt6574-p1rdt8915)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25a9ec20-35b9-4262-a02d-cafa63e5ee42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9ef9958-5d9e-4907-91cd-4c5d099daaf1"}}}], "length": {"value": 0.200113, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "01105eeb-78ae-43ca-8fef-2d73d4dd9715", "name": "l(r:p1rdt6574-p1rdt8915)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9ef9958-5d9e-4907-91cd-4c5d099daaf1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "361385c6-bb6d-4bbc-ab7d-4a5774e03d82"}}}], "length": {"value": 0.502215, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8fd323f7-0f6a-46f6-992e-bf7620907a90", "name": "l(r:p1rdt6574-p1rdt6581)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "599c6ed9-5ff7-4c97-a469-adceecaaf902"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25a9ec20-35b9-4262-a02d-cafa63e5ee42"}}}], "length": {"value": 0.214792, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5c51619f-c22d-4bab-88b1-5e86c6461402", "name": "l(r:p1rdt6581-p1rdt9084)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6114624f-81c8-4d9c-8f9a-3ab73158596e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "599c6ed9-5ff7-4c97-a469-adceecaaf902"}}}], "length": {"value": 0.220787, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8f71b6b2-940e-460b-aca1-395123d090d7", "name": "l(r:p1rdt9076-p1rdt9093)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2ce5116-c4f0-4ac7-a34f-3ba44c99d04b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c29179f3-0b4e-449c-8562-a8fcb675be6c"}}}], "length": {"value": 0.0790457, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "10112fc8-0706-4ca6-a9dc-155f2b62b426", "name": "l(r:p1rdt9076-p1rdt9084)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12b4dc99-fe50-457c-90aa-48a2fb19ebf1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2ce5116-c4f0-4ac7-a34f-3ba44c99d04b"}}}], "length": {"value": 0.143642, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7a562dd7-062c-47c7-a967-a36881222871", "name": "l(r:p1rdt9085-p1rdt9091)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "563c6bb3-d8ed-4fce-ad66-3892426248df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7fcdf409-885c-4c95-834e-988842ed3f5c"}}}], "length": {"value": 0.037383000000000007, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "816469ff-5ef9-491d-a0e5-f0cd167e7249", "name": "l(r:p1rdt9090-p1rdt9091)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf719d10-8168-4d80-894e-1b1516f033e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "563c6bb3-d8ed-4fce-ad66-3892426248df"}}}], "length": {"value": 0.176401, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f21c5d48-35f7-48b8-b0e3-e303cb6e0d3a", "name": "l(r:p1rdt9469-p1rdt9470)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5f6a2ec-3ddd-4ba7-9c55-88b4d82e7735"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acf91e46-ba32-44c3-a829-14c80a693d7d"}}}], "length": {"value": 0.0968012, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4f55c8b3-52d9-48bd-80b9-4336d109293f", "name": "l(r:p1rdt5140-p1rdt5184)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "431b672b-cb45-4294-b1f9-1d63f4efc8db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ceb58d66-3cb3-416d-aedf-f4949432eb37"}}}], "length": {"value": 0.11451800000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "87ff4d03-1265-417f-8396-f2223bf91dc2", "name": "l(r:p1rdt5140-p1rdt5184)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ceb58d66-3cb3-416d-aedf-f4949432eb37"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b0fd055-d0ac-4678-a8e5-679e12741736"}}}], "length": {"value": 0.0332053, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "049715c6-15cd-4adc-bfcb-405451aa8567", "name": "l(r:p1rdt5154-p1rdt5184)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50332aed-ecfd-465a-977e-c24ed6462860"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "431b672b-cb45-4294-b1f9-1d63f4efc8db"}}}], "length": {"value": 0.120991, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "76f0c663-18fa-4b81-a500-c47e1e85102e", "name": "l(r:p1rdt5142-p1rdt5154)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d579047b-82f6-49bf-bd7b-28c818d44bb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50332aed-ecfd-465a-977e-c24ed6462860"}}}], "length": {"value": 0.334614, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "756d1a3b-80d5-45f2-b945-05ac9c864cc7", "name": "l(r:p1rdt5142-p1rdt5180)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d579047b-82f6-49bf-bd7b-28c818d44bb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6316fa2-dd57-46d4-89c0-f11dd675d686"}}}], "length": {"value": 0.304739, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "23f00fb1-3a44-456d-adfc-200b1c385382", "name": "l(r:p1rdt5142-p1rdt8414)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b48f78d-1092-4536-bfb3-029da6a70dff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50f71b3d-83ce-4526-8057-4a38042b7295"}}}], "length": {"value": 0.0685574, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "e62ca4d7-5c98-4352-9f1d-520696b1d502", "name": "l(r:p1rdt5142-p1rdt8414)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50f71b3d-83ce-4526-8057-4a38042b7295"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d579047b-82f6-49bf-bd7b-28c818d44bb3"}}}], "length": {"value": 0.517385, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "591186a8-ed4e-49a7-a103-b77dc41ee44c", "name": "l(r:p1rdt6409-p1rdt8414)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42929633-40d4-4e13-a0aa-a7682f328226"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8648275-54c9-48e3-82e0-33119313924d"}}}], "length": {"value": 0.184195, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "712a1997-2d23-4337-adc2-b4f3245b7797", "name": "l(r:p1rdt6409-p1rdt8414)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8648275-54c9-48e3-82e0-33119313924d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b48f78d-1092-4536-bfb3-029da6a70dff"}}}], "length": {"value": 0.718647, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "40a640c0-70ae-4ede-af89-011fe2f9c3d6", "name": "l(r:p1rdt6409-p1rdt9413)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f750e531-5ade-40a9-9bb0-042220ce9807"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42929633-40d4-4e13-a0aa-a7682f328226"}}}], "length": {"value": 1.30529, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "9557eec3-679c-4760-af42-931b0ecaf811", "name": "l(r:p1rdt7570-p1rdt7574)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9b94106-b7c5-4ce9-9c19-053487848c2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd487832-bc77-406f-a995-4b099fad7c64"}}}], "length": {"value": 0.145959, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "4d38ea75-cd04-43b1-8a35-82c9b0e08cfb", "name": "l(r:p1rdt6275-p1rdt7570)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08d4c459-5bc5-4cad-8e74-613c4a08cb35"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9b94106-b7c5-4ce9-9c19-053487848c2a"}}}], "length": {"value": 0.362236, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "2e63b32d-43ae-42f8-bfbc-1179dc97926a", "name": "l(r:p1rdt6270-p1rdt6275)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cf36152-b3af-49f7-b693-5d465db1f283"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08d4c459-5bc5-4cad-8e74-613c4a08cb35"}}}], "length": {"value": 0.224093, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "a4f133cd-d305-41fc-9adf-8e347daa1943", "name": "l(r:p1rdt6269-p1rdt6270)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5ef97a6-6c60-46eb-acce-6469b273658a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cf36152-b3af-49f7-b693-5d465db1f283"}}}], "length": {"value": 0.284296, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "03db94ff-d792-433b-a8ab-a92dd86752d7", "name": "l(r:p1rdt6269-p1rdt8405)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60829dab-c129-4017-961a-81435d8afa93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5ef97a6-6c60-46eb-acce-6469b273658a"}}}], "length": {"value": 0.466915, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "afade1f8-1732-423e-b3af-635852b088ba", "name": "l(r:p1rdt8405-p1rdt9413)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16ecb938-cd0c-4be5-a915-be0d84d351f2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60829dab-c129-4017-961a-81435d8afa93"}}}], "length": {"value": 1.34967, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "aabe9c80-a880-4171-a383-28382ce12704", "name": "l(r:p1rdt6518-p1rdt9314)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d25f8d60-8aa7-4975-96dc-eba7696fa8ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d39c608-5688-4e22-8ac4-96b896265274"}}}], "length": {"value": 0.0596908, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "c08967c9-6afc-4436-b958-5f3dec162e2a", "name": "l(r:p1rdt9314-p1rdt9479)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b006c3-79f8-4a27-b76a-d1b458ff2a21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d25f8d60-8aa7-4975-96dc-eba7696fa8ae"}}}], "length": {"value": 0.23881800000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d9a45f7b-94cd-476f-b492-6be6d2c3273f", "name": "l(r:p1rdt6539-p1rdt9479)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9707f264-8f82-4483-8337-6c89d709faf7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b006c3-79f8-4a27-b76a-d1b458ff2a21"}}}], "length": {"value": 0.04213, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "5b6a5df1-5751-419e-9043-c59af2cb8468", "name": "l(r:p1rdt6507-p1rdt6539)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0db3e719-4dba-4b45-af70-c35546c19eb4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9707f264-8f82-4483-8337-6c89d709faf7"}}}], "length": {"value": 0.0349385, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "26afa7b6-b653-49b5-bf12-aa3c4938736f", "name": "l(r:p1rdt6507-p1rdt6530)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40ec7437-80f0-49e8-806a-c696b1402713"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0db3e719-4dba-4b45-af70-c35546c19eb4"}}}], "length": {"value": 0.28028700000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "221d6d6b-ad9e-406a-bf03-4b61c0d4feff", "name": "l(r:p1rdt6517-p1rdt6530)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b56340a0-81f0-4028-9283-532f0d92a412"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40ec7437-80f0-49e8-806a-c696b1402713"}}}], "length": {"value": 0.110659, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f60c7b67-fc17-4837-8efd-81efa3b23616", "name": "l(r:p1rdt6517-p1rdt6523)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "608945f2-9b19-43bc-83d9-0fe8787b06b4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b56340a0-81f0-4028-9283-532f0d92a412"}}}], "length": {"value": 0.281764, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "2c421fa7-4dd6-491c-998e-efe7bdb6b9f8", "name": "l(r:p1rdt6520-p1rdt6523)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24028ccd-3fd3-4461-b83c-54266f91a385"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b540c710-395d-4a35-8dc3-59d37609df09"}}}], "length": {"value": 0.0397382, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "ed24a3ca-3bd7-4de6-a546-05dc166ef9c8", "name": "l(r:p1rdt6501-p1rdt6520)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99fa55d1-867c-4db0-8697-b532da10d6d4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24028ccd-3fd3-4461-b83c-54266f91a385"}}}], "length": {"value": 0.0288844, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "be507d1a-0e3c-4956-b874-c26265167d1f", "name": "l(r:p1rdt6499-p1rdt6501)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "89434ebc-1e79-4414-9925-1a14f8e72fd6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99fa55d1-867c-4db0-8697-b532da10d6d4"}}}], "length": {"value": 0.0288269, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "6a77ab95-cadc-4be1-a0fe-1c155f22727c", "name": "l(r:p1rdt6499-p1rdt6509)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67c889f-e940-4242-9c83-4b5ab673d8a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "89434ebc-1e79-4414-9925-1a14f8e72fd6"}}}], "length": {"value": 0.026420600000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "b4fb2c7c-087c-479f-bb54-c153ff040105", "name": "l(r:p1rdt6508-p1rdt6509)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e165d0d-3f13-4d87-9c4b-fdfa8829f1f3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67c889f-e940-4242-9c83-4b5ab673d8a8"}}}], "length": {"value": 0.0278115, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "aac50a47-c224-459e-8507-4369a4d11f3a", "name": "l(r:p1rdt6508-p1rdt6521)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "302d2adf-2199-47b2-9f3c-e428bb409b6f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e165d0d-3f13-4d87-9c4b-fdfa8829f1f3"}}}], "length": {"value": 0.0189224, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f8244459-83a4-4ad3-a604-ec873ed20732", "name": "l(r:p1rdt6512-p1rdt6521)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f7572ed-6443-4e6e-8fb8-0b060b9f17ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "302d2adf-2199-47b2-9f3c-e428bb409b6f"}}}], "length": {"value": 0.0189224, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d5d29e6c-2471-43f5-85e9-7d24f91a352f", "name": "l(r:p1rdt6512-p1rdt6524)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ef8c502-c06f-43e5-90e6-23bd0ebcf155"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f7572ed-6443-4e6e-8fb8-0b060b9f17ce"}}}], "length": {"value": 0.0367319, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "672c8944-7a16-40e8-bdda-3b03fca4fecb", "name": "l(r:p1rdt7091-p1rdt7625)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6372a592-5e2d-41c8-819b-f56bfbb58e19"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2324afa4-5274-4392-9a0e-be8dc2bebeba"}}}], "length": {"value": 0.08221500000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f5dbe138-bea6-41cd-b524-27b90637c6e1", "name": "l(r:p1rdt7091-p1rdt7625)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2324afa4-5274-4392-9a0e-be8dc2bebeba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3e6cbe9-d1d3-4c59-981f-dad980f0999b"}}}], "length": {"value": 0.022555100000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f8e4f44c-08eb-469a-80c1-4f48efd02207", "name": "l(r:p1rdt7091-p1rdt7314)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0cf1844f-a32e-40f2-bc96-05fad3bdd88d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6372a592-5e2d-41c8-819b-f56bfbb58e19"}}}], "length": {"value": 0.55397, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "257675fc-6733-4332-ac51-3675463a4f35", "name": "l(r:p1rdt7314-p1rdt7318)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e86bc267-1607-4aa3-916f-ed826b0adfdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0cf1844f-a32e-40f2-bc96-05fad3bdd88d"}}}], "length": {"value": 0.048033200000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "e1ad2ae6-ae2b-46ab-a690-ea8d77ccc596", "name": "l(r:p1rdt7307-p1rdt7318)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "231b5cf9-ec2c-47d1-aada-5454926561dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e86bc267-1607-4aa3-916f-ed826b0adfdc"}}}], "length": {"value": 0.608118, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "12afdbdb-d635-4f2e-935d-dd9e846d84de", "name": "l(r:p1rdt6531-p1rdt7307)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8431ef4c-78dd-4a39-b15a-95818cfe1d86"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "231b5cf9-ec2c-47d1-aada-5454926561dd"}}}], "length": {"value": 0.626542, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "b628bac6-cc49-4fd0-869c-1e62b4f793f3", "name": "l(r:p1rdt6527-p1rdt6531)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "483b2d65-b496-4c6f-b01d-66aa3d9d4334"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "385eabe4-8c8e-4354-96ec-931e6c25574d"}}}], "length": {"value": 0.0295001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "00137112-a43a-4501-803e-980b8f2c0003", "name": "l(r:p1rdt6516-p1rdt6527)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5bd908fd-8bb8-42c1-8d1b-27c4e2574450"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "483b2d65-b496-4c6f-b01d-66aa3d9d4334"}}}], "length": {"value": 0.010689800000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "94115f94-82fa-4272-8a62-027168f25e3c", "name": "l(r:p1rdt6516-p1rdt6524)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ef8c502-c06f-43e5-90e6-23bd0ebcf155"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6191a237-532b-44e2-86a8-d9ed56b914b5"}}}], "length": {"value": 0.186537, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "5191d34f-932a-42dc-a5d6-0c1c0862b244", "name": "l(r:p1rdt6516-p1rdt6524)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6191a237-532b-44e2-86a8-d9ed56b914b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5bd908fd-8bb8-42c1-8d1b-27c4e2574450"}}}], "length": {"value": 0.014510300000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "310cb070-188c-4ff2-b290-6e36abcf555d", "name": "l(r:p1rdt6500-p1rdt6524)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a3d9ed9-e2e4-4332-89a2-358441869830"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97b7ef3c-ef16-4c4d-8559-722c5c67749a"}}}], "length": {"value": 0.0745596, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "beccb173-6f7b-4721-b3fb-e81b2efdd09f", "name": "l(r:p1rdt6500-p1rdt6515)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "18b822d0-cbe4-48d7-a818-87e25412d241"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0043b26d-8a33-4e32-a963-c4638f943775"}}}], "length": {"value": 0.030964300000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "de841033-13d8-4afb-bc0f-c55d72e49c5f", "name": "l(r:p1rdt6515-p1rdt6528)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04c3a970-215a-4e16-a798-80496ffad438"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8dcd059f-292b-4f7a-96c1-a3dc185f1eec"}}}], "length": {"value": 0.00777706, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "b9b34d6f-9985-4065-9d2f-788d5fa538da", "name": "l(r:p1rdt6528-p1rdt8898)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "918984ec-3b5f-4174-9bca-771bb10e0f60"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0156ae64-03dc-4ec0-89c8-8b09a6fc9090"}}}], "length": {"value": 0.0437869, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "75f64198-30d0-4129-ae28-939b6b4de497", "name": "l(r:p1rdt6532-p1rdt8898)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b51e96e7-2d7f-42af-9115-c9b1cfb3131c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "af1707bf-0b2e-4f76-96e7-c01338300d45"}}}], "length": {"value": 0.019358300000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "f1c45b69-986f-4c1d-aeaa-730d016e991d", "name": "l(r:p1rdt6532-p1rdt8902)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4a0469e-1a4a-466d-b18d-f3017b6415ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f373554-9d8a-4a9c-b418-25e67fbb43a9"}}}], "length": {"value": 0.0333077, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "88bad2e7-4dc4-4e4e-8175-a2a884f68169", "name": "l(r:p1rdt6052-p1rdt8902)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68b101ef-d71a-44d2-b1c2-4fc5e9f62499"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "468b1ce8-18fa-423b-99ca-1f3784437721"}}}], "length": {"value": 0.238793, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "eb115d37-81ae-4650-84a2-ae2f15289db2", "name": "l(r:p1rdt6046-p1rdt6052)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99e2ec8b-60fc-4a79-9eed-0d617babcb1d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49c69b43-f43b-4576-bbfa-d06b1d27de95"}}}], "length": {"value": 0.00843437, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "31a466b8-12d6-4b44-9bbb-89a8c774f869", "name": "l(r:p1rdt6043-p1rdt6046)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be3d7f84-84e7-46fc-a9ce-b3e0cf74d1d3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a147dd91-5597-40ff-93f9-0522ad3c726c"}}}], "length": {"value": 0.00839446, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "70cd133d-d616-4b6b-9e07-48fb34f306c9", "name": "l(r:p1rdt6043-p1rdt6045)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f01bba4-b8e8-45ed-af3b-1ac5a287ad46"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48d6768a-45e6-48a5-b22d-d5d418cb6221"}}}], "length": {"value": 0.04888200000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "f868b3e3-cc69-41ce-bcc7-0f7f802d7449", "name": "l(r:p1rdt6045-p1rdt6047)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34a9d21e-bcf7-4266-9834-60a72878ddd4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0396342e-2dc8-4a01-9da9-513953f9b5fa"}}}], "length": {"value": 0.08483280000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d8f16031-320a-40d2-a4bd-5b0e851ebb6c", "name": "l(r:p1rdt6038-p1rdt6047)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8898950-d712-40dc-99b5-33882b96b225"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34a9d21e-bcf7-4266-9834-60a72878ddd4"}}}], "length": {"value": 0.326021, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "598670a4-8ad9-464f-86c2-e9d706cc1558", "name": "l(r:p1rdt6038-p1rdt7599)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a086b782-3a8d-44e9-9948-cb7f051219e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cfe89e9-a7a8-456d-966b-67429017f456"}}}], "length": {"value": 0.186303, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "7223b7c0-3936-4480-8848-42bffaf1bdd0", "name": "l(r:p1rdt6038-p1rdt7599)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cfe89e9-a7a8-456d-966b-67429017f456"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8898950-d712-40dc-99b5-33882b96b225"}}}], "length": {"value": 2.13472, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "4d3942b3-144d-4b5b-82b8-ec7da5fb43f7", "name": "l(r:p1rdt6221-p1rdt7599)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0809ec5e-d36f-4bea-91b3-962ad6c29606"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a086b782-3a8d-44e9-9948-cb7f051219e3"}}}], "length": {"value": 0.192328, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d39bfedb-aa0c-466a-a29d-3c01eaa13638", "name": "l(r:p1rdt6208-p1rdt6221)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdfc617f-fbfb-4e9a-862e-cd5a296748cb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1a5a109-eee6-46be-be53-3fbe4a406575"}}}], "length": {"value": 0.728973, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "938225b2-6c7d-477d-9191-27d235904197", "name": "l(r:p1rdt6208-p1rdt6221)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1a5a109-eee6-46be-be53-3fbe4a406575"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0809ec5e-d36f-4bea-91b3-962ad6c29606"}}}], "length": {"value": 0.0421438, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "e39ddd12-2c19-406b-9cee-39fbbb7419bc", "name": "l(r:p1rdt6208-p1rdt8805)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "89f0c671-9d27-4dec-bd37-dc6c56f07e5d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdfc617f-fbfb-4e9a-862e-cd5a296748cb"}}}], "length": {"value": 0.531617, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "275d987b-6998-408d-8232-9db51e45c450", "name": "l(r:p1rdt5656-p1rdt5662)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17e89212-bc51-4fc2-83d1-4c74a285be23"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6f2bb66-d966-4228-8a13-96c57e8fbfba"}}}], "length": {"value": 0.240242, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "9904f6ea-b491-47e9-85aa-4261c1779673", "name": "l(r:p1rdt5656-p1rdt5662)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6f2bb66-d966-4228-8a13-96c57e8fbfba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f417a58d-5a47-4310-bac6-e8bb95fffc19"}}}], "length": {"value": 0.0265639, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "4573256d-e96e-413f-ac6b-b2c223599e79", "name": "l(r:p1rdt5183-p1rdt5662)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23f0bb81-3c30-45a5-89ca-2011e3881ddb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a05b2959-a8dd-417b-b566-8f84384a3559"}}}], "length": {"value": 0.290891, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "269826f4-1e62-47ca-aa90-96572f804c44", "name": "l(r:p1rdt5183-p1rdt5662)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a05b2959-a8dd-417b-b566-8f84384a3559"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17e89212-bc51-4fc2-83d1-4c74a285be23"}}}], "length": {"value": 1.81146, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "3f70e4f0-d581-4f32-bd85-f3b84da4c8ca", "name": "l(r:p1rdt4980-p1rdt5183)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35487e15-57cb-4e19-bef7-49074e5eb9ee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23f0bb81-3c30-45a5-89ca-2011e3881ddb"}}}], "length": {"value": 0.269563, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d3c03d49-abd6-4de6-8181-afe2d64d9e2a", "name": "l(r:p1rdt4980-p1rdt5017)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c09f718-9379-4281-86f6-55c46e46aec6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ddb0629-4947-47ca-83f9-9b7c073db235"}}}], "length": {"value": 0.216088, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "1c2a6e83-cb95-42de-bb6b-7b0e1cd4ea71", "name": "l(r:p1rdt4964-p1rdt5017)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7f13598-e628-457c-9ba6-d9a0123e882c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf1c765f-ca54-48cf-806f-6a1b5719c4b0"}}}], "length": {"value": 0.261316, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "eac4420e-03e8-40b1-ad16-db8f5eca18fc", "name": "l(r:p1rdt4964-p1rdt5017)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf1c765f-ca54-48cf-806f-6a1b5719c4b0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c09f718-9379-4281-86f6-55c46e46aec6"}}}], "length": {"value": 0.0641008, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "3b99e76c-8a82-4ca1-a9a0-80ecff2a4603", "name": "l(r:p1rdt4964-p1rdt8154)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42ab6054-1866-49c5-b2ab-3cf27199c1c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb1e0d86-907d-4564-a90e-c1400917d3ca"}}}], "length": {"value": 0.341502, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "55ed643d-0afa-4989-b1fd-d0adb37d81c8", "name": "l(r:p1rdt4964-p1rdt8154)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb1e0d86-907d-4564-a90e-c1400917d3ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7f13598-e628-457c-9ba6-d9a0123e882c"}}}], "length": {"value": 0.865306, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "5492331e-5c0a-4016-8ba0-bdc8e5d4f098", "name": "l(r:p1rdt8151-p1rdt8153)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b44d5021-4fdb-4618-bcb2-237ecf2e10e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40962258-28d3-4406-9e9e-121f373cce25"}}}], "length": {"value": 0.18735, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "05f00c42-916f-4b90-9aa8-833526068343", "name": "l(r:p1rdt8151-p1rdt8153)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40962258-28d3-4406-9e9e-121f373cce25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c794942-d5ce-481f-9c6a-563a2180a4ba"}}}], "length": {"value": 0.010421300000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d252c5f0-0b34-4738-8838-259761123b3c", "name": "l(r:p1rdt8153-p1rdt8154)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42ab6054-1866-49c5-b2ab-3cf27199c1c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b44d5021-4fdb-4618-bcb2-237ecf2e10e4"}}}], "length": {"value": 0.112826, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f7417ff2-16a5-4e81-a26b-dc86e9be6115", "name": "l(r:p1rdt8154-p1rdt9333)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0da91bf8-b687-47df-a7dc-41e6166fd667"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aef77ef-aaaa-4a6e-90ef-87348baaf1a0"}}}], "length": {"value": 0.37829, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "398b071f-89c3-461e-a564-1de7f6d5c967", "name": "l(r:p1rdt8154-p1rdt9333)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aef77ef-aaaa-4a6e-90ef-87348baaf1a0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42ab6054-1866-49c5-b2ab-3cf27199c1c8"}}}], "length": {"value": 0.2985030000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "76623ce2-1798-436d-8d11-cfcdc4e48d8e", "name": "l(r:p1rdt8805-p1rdt9333)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3444af6b-f9d4-4229-b6b2-2114300c3f94"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0da91bf8-b687-47df-a7dc-41e6166fd667"}}}], "length": {"value": 0.4807600000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "b055443b-30b0-4f4b-bbe3-54ed03e935bc", "name": "l(r:p1rdt8802-p1rdt8805)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26ccaeff-3a34-4835-8906-1145148549c6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3444af6b-f9d4-4229-b6b2-2114300c3f94"}}}], "length": {"value": 0.287236, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "62bc44cf-8afa-47da-9b7f-18b3ec7b3fff", "name": "l(r:p1rdt8802-p1rdt9413)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "401576cc-4ad6-42cd-bf1c-4022da720711"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e527bf48-b574-43bd-9a5d-484654dc76fe"}}}], "length": {"value": 1.38145, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "19fd814e-e169-4dc3-a33e-fae841593afd", "name": "l(r:p1rdt8802-p1rdt9413)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e527bf48-b574-43bd-9a5d-484654dc76fe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26ccaeff-3a34-4835-8906-1145148549c6"}}}], "length": {"value": 0.181709, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "06dd8bda-4d2d-43a7-a006-b168f73e922c", "name": "l(r:p1rdt5126-p1rdt9413)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0dafde2-c08e-4624-9212-e0fea9e47c2c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f750e531-5ade-40a9-9bb0-042220ce9807"}}}], "length": {"value": 1.23272, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "243ed967-e94e-485e-8b9d-afcbd257a23f", "name": "l(r:p1rdt5126-p1rdt5342)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c8f9ea6-06fb-4fd0-8629-ceea4f32189f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0dafde2-c08e-4624-9212-e0fea9e47c2c"}}}], "length": {"value": 1.97105, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "1a44ac5c-bd61-4c05-add0-330d7b09af79", "name": "l(r:p1rdt5476-p1rdt7624)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e240270-762d-49f0-a4e4-29fcd6273ce5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b077dc9c-1c6f-4403-ae0c-954e7cc0c692"}}}], "length": {"value": 0.421903, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "cc2acfa4-f76c-49fb-9790-7a02064a106b", "name": "l(r:p1rdt7624-p1rdt8159)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42b9c576-ddba-4be1-bc64-a37d8cbdfa84"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1ab9716-b9f3-44e5-b9f6-cd83d0904dd3"}}}], "length": {"value": 0.172459, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f0f84804-681f-45a5-b03b-c90ab2f2d6ff", "name": "l(r:p1rdt7624-p1rdt8159)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1ab9716-b9f3-44e5-b9f6-cd83d0904dd3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e240270-762d-49f0-a4e4-29fcd6273ce5"}}}], "length": {"value": 0.601263, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "542b2bb0-327d-4aab-a521-e1b0208513fc", "name": "l(r:p1rdt8159-p1rdt8161)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25946c74-15c2-412c-baed-8de5f7aecf98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42b9c576-ddba-4be1-bc64-a37d8cbdfa84"}}}], "length": {"value": 0.18407100000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "007f222e-ee77-4ddd-a2b9-453252e10c12", "name": "l(r:p1rdt7253-p1rdt8470)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f31b09da-e4cc-409e-9634-1907480039ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "442de065-9e2a-4ff8-9100-1298d3fe0f6f"}}}], "length": {"value": 1.51192, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f872437e-3f61-48ba-b719-7dec231c6092", "name": "l(r:p1rdt7248-p1rdt7253)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a006c5f-e960-4ae2-a37f-d23d7b873a22"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f31b09da-e4cc-409e-9634-1907480039ff"}}}], "length": {"value": 0.16946100000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "126d74f6-247e-4072-a5df-2c3d434063f3", "name": "l(r:p1rdt7220-p1rdt7248)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a2f1a631-48f7-4291-9adb-588a66620ebf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a006c5f-e960-4ae2-a37f-d23d7b873a22"}}}], "length": {"value": 0.306328, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "05aee401-6d4c-4709-8f97-3c50231daf5e", "name": "l(r:p1rdt7220-p1rdt8160)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38b72c12-2e2f-4d83-8f5a-9d8503dc29eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a2f1a631-48f7-4291-9adb-588a66620ebf"}}}], "length": {"value": 0.197573, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "95d74719-df14-429b-a976-0df68eb96622", "name": "l(r:p1rdt9075-p1rdt9084)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "907828f5-8e26-41c4-8fbc-a3744608181a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c10b6848-6c57-4243-8cb9-ec28d0a4c9dd"}}}], "length": {"value": 0.178898, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "3eafde29-da04-4c84-8fb6-7f4688eda991", "name": "l(r:p1rdt9075-p1rdt9084)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c10b6848-6c57-4243-8cb9-ec28d0a4c9dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4251587d-600f-40a0-9aec-229fb2e3f2df"}}}], "length": {"value": 0.27713400000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "fd3b2cfd-59b4-44c7-b0e7-303bae472d10", "name": "l(r:p1rdt9075-p1rdt9077)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b7f2f09-976a-45da-8186-229aeedeb689"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "907828f5-8e26-41c4-8fbc-a3744608181a"}}}], "length": {"value": 0.564064, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "347ee642-da70-4556-80d2-c3ac791c95eb", "name": "l(r:p1rdt9077-p1rdt9089)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b4ec275-bea8-45f2-94cb-5e24e82179d8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b7f2f09-976a-45da-8186-229aeedeb689"}}}], "length": {"value": 0.0696185, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f1cb1cc4-91cf-4ec1-a7a3-133827bae335", "name": "l(r:p1rdt9089-p1rdt9090)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52c72b52-1c6c-46f6-adbe-1054eb233c20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e4d2db3-67c5-4fef-996a-5774803c89b1"}}}], "length": {"value": 0.172405, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "fd0103af-8848-4f0a-8530-fac681f8ac46", "name": "l(r:p1rdt9089-p1rdt9090)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e4d2db3-67c5-4fef-996a-5774803c89b1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b4ec275-bea8-45f2-94cb-5e24e82179d8"}}}], "length": {"value": 0.0139334, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "df82aa08-b98c-4a21-89f9-d1b76cfe2af4", "name": "l(r:p1rdt9090-p1rdt9469)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3fd32c7-2866-4699-93a8-dd3a9997d349"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "708803a5-3daf-4892-96e3-b182e2d214ec"}}}], "length": {"value": 0.170175, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "fcb909f2-d354-474b-aee1-a6ca2eb94969", "name": "l(r:p1rdt9090-p1rdt9469)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "708803a5-3daf-4892-96e3-b182e2d214ec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52c72b52-1c6c-46f6-adbe-1054eb233c20"}}}], "length": {"value": 0.101162, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "2825eafe-8b85-450e-bed0-ab9a8e074f2d", "name": "l(r:p1rdt8160-p1rdt9469)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38b72c12-2e2f-4d83-8f5a-9d8503dc29eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3fd32c7-2866-4699-93a8-dd3a9997d349"}}}], "length": {"value": 0.245773, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "13deaf06-081a-4c2c-b09a-13b3d3c7335b", "name": "l(r:p1rdt8160-p1rdt8161)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8ecbd5b-6db5-44a0-b2a8-0233d4eb5b20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc9cbaf2-05bd-49aa-bd14-a363d4970d0f"}}}], "length": {"value": 0.191607, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "c5288543-a096-4660-bf4a-2929c4c54201", "name": "l(r:p1rdt8160-p1rdt8161)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc9cbaf2-05bd-49aa-bd14-a363d4970d0f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38b72c12-2e2f-4d83-8f5a-9d8503dc29eb"}}}], "length": {"value": 0.415051, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "b887aaee-21fc-4122-9966-afa362c2a743", "name": "l(r:p1rdt5236-p1rdt8161)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22db53ea-6d9a-4527-9b36-34a4bcd2c74f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67967bdd-155c-49fd-8d4c-29b40415a243"}}}], "length": {"value": 0.0839258, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f602002d-891a-4cda-82bc-55026a5de403", "name": "l(r:p1rdt5236-p1rdt8161)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67967bdd-155c-49fd-8d4c-29b40415a243"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25946c74-15c2-412c-baed-8de5f7aecf98"}}}], "length": {"value": 0.757497, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "10415944-6d9a-4497-bbb6-d304cebe9536", "name": "l(r:p1rdt5236-p1rdt5342)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9bbfae79-a578-4ff2-b622-3dddd9859ac8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22db53ea-6d9a-4527-9b36-34a4bcd2c74f"}}}], "length": {"value": 1.97703, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f8620c0f-f6b7-4b1c-abcf-c32e418abafc", "name": "l(r:p1rdt5342-p1rhs7_1247)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14208aa5-3197-4c90-adf9-3067dae9b5f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c8f9ea6-06fb-4fd0-8629-ceea4f32189f"}}}], "length": {"value": 0.373586, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "038d8c23-c731-48d4-9f20-56de4007395d", "name": "l(r:p1rdt5154lv-p1rlv10539)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9750085f-4afd-48ee-89f3-edbe9687b242"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08331744-08b7-455e-b2ca-284cae95fb06"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "4897e763-4729-42e4-a83c-2555a1a08472", "name": "l(r:p1rdt7632lv-p1rlv16271)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7235cf3a-dd26-47f7-884c-6335024a3064"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "606bf8f6-d745-4220-8cae-e01ffd22f669"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "323fd365-c57f-480b-9a0d-7f496d60a8db", "name": "l(r:p1rdt7632-p1rdt9265)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b336e76f-17f3-4f5d-ba84-f24c3a4e3eed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36e7cd28-6795-41d5-847d-92347871384f"}}}], "length": {"value": 0.178943, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "78cda3f2-1738-44fb-b107-a25d2930dde8", "name": "l(r:p1rdt5140-p1rdt9265)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b0fd055-d0ac-4678-a8e5-679e12741736"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60837f06-40cb-4f12-b36f-fe5e502c96d9"}}}], "length": {"value": 0.223266, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "455cb6d9-470c-4b2b-bfd7-589240e9226b", "name": "l(r:p1rdt5140-p1rdt9265)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60837f06-40cb-4f12-b36f-fe5e502c96d9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b336e76f-17f3-4f5d-ba84-f24c3a4e3eed"}}}], "length": {"value": 0.0122242, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "97bf6cd1-1211-4a45-8bf3-7091c7785df7", "name": "l(r:p1rdt6279lv-p1rlv13061)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6614f5e-517f-46cf-b049-09337d57228a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d46fd47-37f5-48a0-ba0d-d0746e6e6da3"}}}], "length": {"value": 0.0894278, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "a35032da-9a40-4dfe-ac94-e654ae966ae4", "name": "l(r:p1rdt6270-p1rdt6279)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb21415c-fc85-4197-82e5-545cb7be2ce9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1565cfb-f699-47db-9cbf-a76c32e3ea69"}}}], "length": {"value": 0.141369, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "f782b59f-9336-471b-a725-6924905057a8", "name": "l(r:p1rdt6270-p1rdt6279)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1565cfb-f699-47db-9cbf-a76c32e3ea69"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5c579309-9c05-4bae-ab97-2eca485e5ea7"}}}], "length": {"value": 0.0289817, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "e34d7eec-d2c0-4c8f-b361-a88dcd056e29", "name": "l(r:p1rdt6273lv-p1rlv13050)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07992f45-0c92-4a10-837d-4f58599d9b75"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "051eba03-4728-4626-8add-5410b5326dc7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "f937594c-fb88-439e-99c9-fda1597eefef", "name": "l(r:p1rdt6268-p1rdt6273)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2f8b91d-339f-4151-90df-b0cad5c2f05a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d04f281-f394-432b-8b5c-cc1acb741369"}}}], "length": {"value": 0.0655674, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "6952320e-ff8d-460d-a4e6-eaf6036b287a", "name": "l(r:p1rdt6268-p1rdt6276)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b31c2adb-e4f4-4211-aac7-f317bf325d12"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce404489-b775-486b-9379-a30c801f6f94"}}}], "length": {"value": 0.246128, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "10f741eb-d2e6-4be0-af4e-b361024769a0", "name": "l(r:p1rdt6268-p1rdt6276)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce404489-b775-486b-9379-a30c801f6f94"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68d2e030-852f-44f6-9e02-d5587a1fc6a0"}}}], "length": {"value": 0.05302, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "84492e74-9344-46cb-a390-f1e004543e53", "name": "l(r:p1rdt6276-p1rdt6278)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51eefb94-724e-4dfe-9823-0f6cf8f56101"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "315af04d-a032-43a8-a2da-b9e68fd21f39"}}}], "length": {"value": 0.154279, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "62a19b90-201e-4b90-8182-f185a38720e2", "name": "l(r:p1rdt6277-p1rdt6278)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1dd4f893-7921-41c3-9e9e-d33e3680a999"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51eefb94-724e-4dfe-9823-0f6cf8f56101"}}}], "length": {"value": 0.0625926, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "b95ba635-9420-4efc-b1f4-f18ab2981eb2", "name": "l(r:p1rdt6269-p1rdt6277)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5ef97a6-6c60-46eb-acce-6469b273658a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "699595d6-8e08-41b1-8c3a-2aef170bb5f7"}}}], "length": {"value": 0.114982, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "6a531a0c-c604-445f-ad7e-c5819157e2fe", "name": "l(r:p1rdt6269-p1rdt6277)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "699595d6-8e08-41b1-8c3a-2aef170bb5f7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1dd4f893-7921-41c3-9e9e-d33e3680a999"}}}], "length": {"value": 0.0390023, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "fe16e73d-9f26-4912-b410-968f808d698e", "name": "l(r:p1rdt6045lv-p1rlv12555)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70bad714-71c1-4341-ac40-76312417dd03"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cc71e486-4a44-466d-bc57-85591b269949"}}}], "length": {"value": 0.0236063, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "5d709edf-06ff-4ca8-9765-3865bab61031", "name": "l(r:p1rdt6052lv-p1rlv12567)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d830a1b-6971-4f4d-99bd-945e0785b5aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29476f95-f85b-4843-a847-3d9d99da3b74"}}}], "length": {"value": 0.0045077400000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "9c40129e-b9c4-4aff-b928-c2e84025b91f", "name": "l(r:p1rdt8902lv-p1rlv19164)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d1c8eb9-7f79-49ad-9e93-6c7cdcc95e22"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a02024b5-aa74-4e07-b043-a7a0e8b3e816"}}}], "length": {"value": 0.034742, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "90dd54ce-1778-49cf-a73f-6ed95b6c2526", "name": "l(r:p1rdt6537lv-p1rlv13720)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3f191ff-f8f2-4f13-af83-e67d1fdd366a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fe1a5da7-bdac-46a6-ab32-addc4f02a296"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "94cd3a09-1d25-466d-9330-f377442a7752", "name": "l(r:p1rdt6530-p1rdt6537)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40ec7437-80f0-49e8-806a-c696b1402713"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "45aca6e5-a8ee-4f45-80f3-e227379d33af"}}}], "length": {"value": 0.308478, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "55ed7480-a266-49da-beec-8b1b0d034468", "name": "l(r:p1rdt6530-p1rdt6537)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "45aca6e5-a8ee-4f45-80f3-e227379d33af"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "902291fa-9561-4f40-a4b7-4fd9fdded417"}}}], "length": {"value": 0.00557178, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "6f8d316a-82f6-4fc7-a734-a3c41faef455", "name": "l(r:p1rdt7313lv-p1rlv15628)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41e61263-feb6-4264-965a-fd1309d997a1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13eabcb1-332a-4c7a-8042-214ada721424"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "48ae8b06-1601-4570-9baa-08a0edd126d2", "name": "l(r:p1rdt7313-p1rdt7318)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e86bc267-1607-4aa3-916f-ed826b0adfdc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a3a5e1c-77a2-4a9d-89e0-7d1c94176787"}}}], "length": {"value": 0.478103, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "e93ae957-665d-4d98-9565-61d7fa171d07", "name": "l(r:p1rdt7091lv-p1rlv15196)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0c42b48-7ca4-465f-b17c-048cb5f6d79b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64634ab5-a5b0-45ae-9763-7d0be029350f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "ced3202e-8eab-47a4-a979-fe58903c95a5", "name": "l(r:p1rdt5658lv-p1rlv11679)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f718935b-704d-4374-9172-856511e1eddd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4747e0f3-2a66-4e5a-8160-ac0aabe34489"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "e989189e-1d7f-413f-9447-be9c62919ce6", "name": "l(r:p1rdt5656-p1rdt5658)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f417a58d-5a47-4310-bac6-e8bb95fffc19"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81d6db26-881f-4cae-9514-df4c1e71c76e"}}}], "length": {"value": 0.6035390000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "5ba12d68-d1c2-4a66-b496-c299b151bf39", "name": "l(r:p1rdt5236-p1rdt8138)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0bab7e6b-74a6-4fe4-95e1-4ef96084f730"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22db53ea-6d9a-4527-9b36-34a4bcd2c74f"}}}], "length": {"value": 1.28532, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "3bc006be-04ae-45f9-8629-fd4cc42dcf20"}}}}, {"uuid": "76ff5ca6-d44b-4b4d-b1b5-c14739844a79", "name": "padswitch(r:p1rdt6270-p1rdt6271)p1r_14586", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "658514b3-59fd-44b7-95d6-a34cafcb47c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28954596-f060-4fa8-9f13-dfaa633bb739"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "47f16deb-bd0f-40f8-bed6-ee102cf95311", "name": "padswitch(r:p1rdt6270-p1rdt6271)p1r_14587", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b81bd5c2-96bb-445e-9eb8-d72360fd8a94"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a75c5e2-2277-42b4-87d4-6eadff5c06f1"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "fdb44f5f-12df-415f-a658-fc222a86212f", "name": "padswitch(r:p1rdt6500-p1rdt6519)p1r_14592", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9938a5c-b1cd-4592-814d-324ff2eb6644"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf648a0d-3262-4150-892b-55c3b117050a"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "6ba5defb-3101-4ef8-8d06-36719f7dad94"}}}}, {"uuid": "c2901c9f-984c-4dce-b45c-7e5ed1da1ce4", "name": "padswitch(r:p1rdt6500-p1rdt6519)p1r_14593", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5789c3b2-eb91-4e4c-85e8-24f5893e1a2c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "addd9f38-279f-4d9e-b216-38faef1940c7"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "fa89ef5e-f965-457f-a553-4831f61b03c7"}}}}, {"uuid": "111ecb31-3bbe-454e-8c3b-6d1f70eb1532", "name": "padswitch(r:p1rdt6515-p1rdt6535)p1r_14598", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acd6da90-895c-4d2c-80b4-1712b3949993"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fec078c2-a5d8-4317-a8ac-bc25772f6358"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "6ba5defb-3101-4ef8-8d06-36719f7dad94"}}}}, {"uuid": "bf3c2744-7527-4dae-99cf-5e2e7a4820ff", "name": "padswitch(r:p1rdt6515-p1rdt6535)p1r_14599", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5a05d0e-8cf2-4ab8-bdfd-24b8cd12ad67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b13053e-033e-4fe9-8eb3-89389e4bdc2b"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "fa89ef5e-f965-457f-a553-4831f61b03c7"}}}}, {"uuid": "2d52f48c-71fe-495c-a82d-13c4ed75d340", "name": "padswitch(r:p1rdt6515-p1rdt6536)p1r_14600", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0103161-4b16-4d25-a1f3-5a939317461f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04c1e05a-9cbb-4e53-9412-1cffd3976bed"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "6ba5defb-3101-4ef8-8d06-36719f7dad94"}}}}, {"uuid": "434eb627-cf53-4216-afff-7c43ac807514", "name": "padswitch(r:p1rdt6515-p1rdt6536)p1r_14601", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5aa6899b-19a2-41e6-b445-f9fe2536c8d9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f5cda74-5e33-4c52-8b2c-76bcd5e6c5cb"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "cbd826fb-5ba3-44b3-9c68-e5792dbd9854"}}}}, {"uuid": "28532c28-7be9-4805-8948-6769b876196e", "name": "padswitch(r:p1rdt6500-p1rdt6524)p1r_14594", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78b3b940-c277-441f-b2b3-83525ed85fcb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a3d9ed9-e2e4-4332-89a2-358441869830"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "d1d26e33-dcd5-4938-ad3f-174e4840c4f5", "name": "padswitch(r:p1rdt6500-p1rdt6524)p1r_14595", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97b7ef3c-ef16-4c4d-8559-722c5c67749a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ef8c502-c06f-43e5-90e6-23bd0ebcf155"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "c63cae3a-2224-4eff-aedd-06790f5bf45d", "name": "padswitch(r:p1rdt6500-p1rdt6515)p1r_14596", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1537ab1-dc7c-4bbd-b347-fc740d54fcf7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "18b822d0-cbe4-48d7-a818-87e25412d241"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "fc796329-2b2a-43b9-80c9-88427ef9b994"}}}}, {"uuid": "b26dbf8c-790a-40b5-ba1c-19b30138e3af", "name": "padswitch(r:p1rdt6500-p1rdt6515)p1r_14597", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0043b26d-8a33-4e32-a963-c4638f943775"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78b3b940-c277-441f-b2b3-83525ed85fcb"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "5f815f51-16da-46fa-b9b7-0a247327f57d", "name": "padswitch(r:p1rdt6515-p1rdt6528)p1r_14602", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ef5115d-ad7b-4671-b984-b9fd5969bf61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04c3a970-215a-4e16-a798-80496ffad438"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "a00c74d5-27a7-4365-a4b4-1caa240257e0", "name": "padswitch(r:p1rdt6515-p1rdt6528)p1r_14603", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8dcd059f-292b-4f7a-96c1-a3dc185f1eec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1537ab1-dc7c-4bbd-b347-fc740d54fcf7"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "fc796329-2b2a-43b9-80c9-88427ef9b994"}}}}, {"uuid": "f1f9def4-cddd-4b19-917f-09d63a013c98", "name": "padswitch(r:p1rdt6528-p1rdt8898)p1r_14604", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d887dbc-43bd-413e-8e72-5c95a2ed0be8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "918984ec-3b5f-4174-9bca-771bb10e0f60"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "1faec6b1-7f5b-4dcb-a048-3049e55d8b38", "name": "padswitch(r:p1rdt6528-p1rdt8898)p1r_14605", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0156ae64-03dc-4ec0-89c8-8b09a6fc9090"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ef5115d-ad7b-4671-b984-b9fd5969bf61"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "8e18082d-6d53-447e-b376-04046779e92e", "name": "padswitch(r:p1rdt6532-p1rdt8898)p1r_14606", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9f12ed7-454c-4cc9-a631-377121a07ba5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b51e96e7-2d7f-42af-9115-c9b1cfb3131c"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "2c2bcd91-cbfd-4595-aaff-70019c10c6fa", "name": "padswitch(r:p1rdt6532-p1rdt8898)p1r_14607", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "af1707bf-0b2e-4f76-96e7-c01338300d45"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d887dbc-43bd-413e-8e72-5c95a2ed0be8"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "c28bad83-c114-4053-9c9b-30bbedcabe0b", "name": "padswitch(r:p1rdt6532-p1rdt8902)p1r_14608", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f44ec9b-338a-4ae1-a26b-26422f218c13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4a0469e-1a4a-466d-b18d-f3017b6415ae"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "d6d0f63a-de65-45e9-bdee-6c551b470065", "name": "padswitch(r:p1rdt6532-p1rdt8902)p1r_14609", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f373554-9d8a-4a9c-b418-25e67fbb43a9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9f12ed7-454c-4cc9-a631-377121a07ba5"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "afa67d84-29d7-4458-849e-84ed0e1b595b", "name": "padswitch(r:p1rdt6052-p1rdt8902)p1r_14610", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c10f182d-aa76-4633-9a84-f41e20b97da1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68b101ef-d71a-44d2-b1c2-4fc5e9f62499"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "fa28c17c-346e-462b-82a7-05a8c4f9581e", "name": "padswitch(r:p1rdt6052-p1rdt8902)p1r_14611", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "468b1ce8-18fa-423b-99ca-1f3784437721"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f44ec9b-338a-4ae1-a26b-26422f218c13"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "b7883a9b-3e71-4054-8da3-871e4aca2b0d", "name": "padswitch(r:p1rdt6046-p1rdt6052)p1r_14612", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67bc3ce6-e23d-4899-b0e8-9783225338ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99e2ec8b-60fc-4a79-9eed-0d617babcb1d"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "6f1d6c03-5c03-49ba-8dab-68f7e30ab2cb", "name": "padswitch(r:p1rdt6046-p1rdt6052)p1r_14613", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49c69b43-f43b-4576-bbfa-d06b1d27de95"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c10f182d-aa76-4633-9a84-f41e20b97da1"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "6639a595-3f1b-44a9-86be-51fa881ce680", "name": "padswitch(r:p1rdt6043-p1rdt6046)p1r_14614", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "87e05b2f-c346-452c-9c72-a6db090c3124"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be3d7f84-84e7-46fc-a9ce-b3e0cf74d1d3"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "91227638-fd33-4479-9525-2d57047db981", "name": "padswitch(r:p1rdt6043-p1rdt6046)p1r_14615", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a147dd91-5597-40ff-93f9-0522ad3c726c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67bc3ce6-e23d-4899-b0e8-9783225338ff"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "689b9014-1cdc-4acc-8b3e-df03f6b21e70", "name": "padswitch(r:p1rdt6043-p1rdt6045)p1r_14616", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0396342e-2dc8-4a01-9da9-513953f9b5fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f01bba4-b8e8-45ed-af3b-1ac5a287ad46"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4900e609-ebb1-44db-852b-602449095f15"}}}}, {"uuid": "03180cf9-2727-4493-8873-aff288e916b6", "name": "padswitch(r:p1rdt6043-p1rdt6045)p1r_14617", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48d6768a-45e6-48a5-b22d-d5d418cb6221"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "87e05b2f-c346-452c-9c72-a6db090c3124"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "6d8a26df-5a49-4e47-869d-4d8122f519ba", "name": "padswitch(r:p1rdt6270-p1rdt6279)p1r_14588", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cf36152-b3af-49f7-b693-5d465db1f283"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb21415c-fc85-4197-82e5-545cb7be2ce9"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "7f30a525-3333-4b58-92ea-577806eca7df", "name": "padswitch(r:p1rdt6270-p1rdt6279)p1r_14589", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5c579309-9c05-4bae-ab97-2eca485e5ea7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "632d8db5-5220-4188-94f0-f6131253820b"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "636897ae-1c34-4ac7-a975-9d28d5b5e703", "name": "padswitch(r:p1rdt6268-p1rdt6276)p1r_14590", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "315af04d-a032-43a8-a2da-b9e68fd21f39"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b31c2adb-e4f4-4211-aac7-f317bf325d12"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "e469ce7f-3983-4e1e-8e32-aa82775148e2", "name": "padswitch(r:p1rdt6268-p1rdt6276)p1r_14591", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68d2e030-852f-44f6-9e02-d5587a1fc6a0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2f8b91d-339f-4151-90df-b0cad5c2f05a"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "7a4d0af0-a80d-4a34-9690-847471cef160", "name": "fuse(r:p1rdt5017-p1rdt5200)p1r_17536", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c09f718-9379-4281-86f6-55c46e46aec6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0843e99-e917-473c-bec7-ee0c3ddec601"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "2c1ba8d6-9c7d-4bff-8436-d9ee96d6015c", "name": "fuse(r:p1rdt5180-p1rdt5201)p1r_17572", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6316fa2-dd57-46d4-89c0-f11dd675d686"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86d3f96e-ffe2-459f-a2f1-b63d7bf138b8"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "b5dcf106-1044-4f87-a7f6-75974485309d", "name": "fuse(r:p1rdt5180-p1rdt7988)p1r_17573", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6316fa2-dd57-46d4-89c0-f11dd675d686"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "893d2436-cd6c-40ad-90af-64ba1ac23f6e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "82ed7871-cb02-4db6-91d5-ce60e7d4e1e2", "name": "fuse(r:p1rdt5472-p1rdt5476)p1r_17641", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b077dc9c-1c6f-4403-ae0c-954e7cc0c692"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d69527e6-70b6-43e2-8b9e-7c8570ad5ddf"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770"}}}}, {"uuid": "82617c5e-c2cc-455d-8527-5601ea90767d", "name": "fuse(r:p1rdt5475-p1rdt5476)p1r_17642", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b077dc9c-1c6f-4403-ae0c-954e7cc0c692"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae343ca3-3337-4528-b117-38a51e6d023f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770"}}}}, {"uuid": "ccf9e034-77fc-426b-b591-d140fef045d2", "name": "fuse(r:p1rdt5476-p1rdt5478)p1r_17643", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b077dc9c-1c6f-4403-ae0c-954e7cc0c692"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c977e6c-43f0-4d7e-b19f-82f0de97dab2"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "a4cfd253-7e2b-44c8-ad94-7e49d479f7d6", "name": "fuse(r:p1rdt5658-p1rdt5663)p1r_17692", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81d6db26-881f-4cae-9514-df4c1e71c76e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81f0e00e-bc49-448a-8e69-0569ed6a8c1a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "d9f2eb29-6d43-4a3e-97a3-82df1571da0f", "name": "fuse(r:p1rdt5658-p1rdt7070)p1r_17693", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81d6db26-881f-4cae-9514-df4c1e71c76e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02407b52-58c3-403c-9b5b-38695f435476"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "9b63d6fe-307e-4ee6-b4a9-7f9f2da30a37", "name": "fuse(r:p1rdt5650-p1rdt5662)p1r_17694", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17e89212-bc51-4fc2-83d1-4c74a285be23"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36c3c493-ff68-4bb8-a3f4-043c5f847bd3"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "30827bea-a4e8-4efe-b4d7-efcfb1e9320b", "name": "fuse(r:p1rdt6270-p1rdt6271)p1r_17809", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3cf36152-b3af-49f7-b693-5d465db1f283"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "658514b3-59fd-44b7-95d6-a34cafcb47c5"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "f0933dbe-d79b-4dc5-a90e-5baecda8695c", "name": "fuse(r:p1rdt5179-p1rdt6273)p1r_17810", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d04f281-f394-432b-8b5c-cc1acb741369"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9722136-480b-44cb-8b0e-0b3165712688"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "af71c4ff-4d6e-4ab4-9d66-7d164afa30e7", "name": "fuse(r:p1rdt6278-p1rdt8439)p1r_17811", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51eefb94-724e-4dfe-9823-0f6cf8f56101"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19d5304c-574f-4646-8095-d2dcbbea86e7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "29527017-032c-4b43-bd84-238ae4b0d637", "name": "fuse(r:p1rdt6500-p1rdt6519)p1r_17854", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78b3b940-c277-441f-b2b3-83525ed85fcb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9938a5c-b1cd-4592-814d-324ff2eb6644"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "861d64ae-aba6-4135-a3ca-f177438722a2"}}}}, {"uuid": "5ba4b830-feba-4c34-9f6a-d9a4acea95aa", "name": "fuse(r:p1rdt6501-p1rdt9468)p1r_17855", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99fa55d1-867c-4db0-8697-b532da10d6d4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddfa01c0-4d12-4f96-ab50-0082ef9914a6"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "d467c779-b0de-4d04-a83b-e77928c92e89", "name": "fuse(r:p1rdt6505-p1rdt6508)p1r_17856", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e165d0d-3f13-4d87-9c4b-fdfa8829f1f3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c0824c21-244b-4d4e-85d6-238ac4908b5a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "e57e9e13-5001-4417-a3f6-ab5934b145e3", "name": "fuse(r:p1rdt6509-p1rdt6514)p1r_17857", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67c889f-e940-4242-9c83-4b5ab673d8a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42f09ae1-037a-4565-9cd2-0187c45b7866"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "dd4f8c56-9e34-4519-b5c5-cbf9f9aef255", "name": "fuse(r:p1rdt6515-p1rdt6535)p1r_17861", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1537ab1-dc7c-4bbd-b347-fc740d54fcf7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acd6da90-895c-4d2c-80b4-1712b3949993"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "ab93cbf0-52fd-4d3d-a7f9-fd7cb4376fa6"}}}}, {"uuid": "f40fc1ae-26eb-4491-bdbb-89a93f0a5ed4", "name": "fuse(r:p1rdt6515-p1rdt6536)p1r_17862", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1537ab1-dc7c-4bbd-b347-fc740d54fcf7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0103161-4b16-4d25-a1f3-5a939317461f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "ab93cbf0-52fd-4d3d-a7f9-fd7cb4376fa6"}}}}, {"uuid": "2aa6f2b8-2a32-42fc-90f2-fa7a8c55098c", "name": "fuse(r:p1rdt6498-p1rdt6516)p1r_17863", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5bd908fd-8bb8-42c1-8d1b-27c4e2574450"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60b93cd6-c9fc-46ef-8b37-6b14d0773df6"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "29b3f03f-9571-4cf7-9677-dfd361d7772d", "name": "fuse(r:p1rdt6518-p1rdt9311)p1r_17864", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d39c608-5688-4e22-8ac4-96b896265274"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95d939ff-e20d-42b3-bb88-f1975f9fa0aa"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770"}}}}, {"uuid": "1b5e8967-c098-465d-af7c-c04a15173c41", "name": "fuse(r:p1rdt6510-p1rdt6523)p1r_17865", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b540c710-395d-4a35-8dc3-59d37609df09"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66b7b2e9-7658-4de0-8197-3829c6179353"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "3dfebf9a-38af-4642-a33a-d6e2ded3d3d3", "name": "fuse(r:p1rdt5728-p1rdt6537)p1r_17866", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "902291fa-9561-4f40-a4b7-4fd9fdded417"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66ef2ffb-e67d-47eb-ae59-194c538ab861"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "99c97fbd-6df7-451e-8cda-f3cbb38af5c8", "name": "fuse(r:p1rdt7036-p1rdt7091)p1r_17967", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6372a592-5e2d-41c8-819b-f56bfbb58e19"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28d17238-8db8-41da-960c-317183423576"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "43c81b03-5700-4da4-8f70-67963aaef0ac", "name": "fuse(r:p1rdt7298-p1rdt7313)p1r_17994", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a3a5e1c-77a2-4a9d-89e0-7d1c94176787"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1f6ad7d-f7ea-4b94-956c-ec4a3b2028d5"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "5536ecf7-d8e7-4008-b350-e418d4c32378", "name": "fuse(r:p1rdt7554-p1rdt7570)p1r_18045", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9b94106-b7c5-4ce9-9c19-053487848c2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2bdb2b51-0526-4995-bb5e-a2bd495488d4"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "6013789b-d1a7-4068-b10a-f2499431a3e3", "name": "fuse(r:p1rdt7559-p1rdt7570)p1r_18046", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9b94106-b7c5-4ce9-9c19-053487848c2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09814176-7891-4fe1-addf-b47aa106c40d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "8c46219e-0ca9-4c62-b0d1-27774f373511", "name": "fuse(r:p1rdt7551-p1rdt7574)p1r_18047", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd487832-bc77-406f-a995-4b099fad7c64"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1d8c14d0-8247-4a44-98c1-4534aa9037a2"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770"}}}}, {"uuid": "15bcd57b-3325-4415-8d0c-e10363a4d084", "name": "fuse(r:p1rdt7553-p1rdt7574)p1r_18048", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd487832-bc77-406f-a995-4b099fad7c64"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f00dd033-8e7c-43af-bd16-1de2954e07be"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "cbed5d9f-5e20-4900-b098-41ced4f2e4c7", "name": "fuse(r:p1rdt7599-p1rdt8492)p1r_18054", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a086b782-3a8d-44e9-9948-cb7f051219e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "605c34bc-3f7c-4eb7-8df0-fcd00d261921"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "87a1de9d-91b1-4052-ab8c-9c01790a77d8", "name": "fuse(r:p1rdt6847-p1rdt7624)p1r_18055", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e240270-762d-49f0-a4e4-29fcd6273ce5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be9350ab-7ad2-4a89-a374-94bf69588d7f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "a063cb46-3701-476f-b259-2890451a38db", "name": "fuse(r:p1rdt7617-p1rdt7625)p1r_18056", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3e6cbe9-d1d3-4c59-981f-dad980f0999b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a11cf3d9-90bb-4de8-b637-6ec9128525ec"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "fc77f72a-a5f7-465d-aa39-93591b6b0878", "name": "fuse(r:p1rdt7621-p1rdt7625)p1r_18057", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3e6cbe9-d1d3-4c59-981f-dad980f0999b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53df7b6e-bd8c-43f2-860d-8869aec5d079"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "d64e4be1-0395-4089-96bf-26178c53784e", "name": "fuse(r:p1rdt7625-p1rdt7631)p1r_18058", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3e6cbe9-d1d3-4c59-981f-dad980f0999b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "460f5de9-8d4f-468a-b67a-b3b05354a9ce"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "09949c3d-86ce-4fb6-a416-b2b63b50edc5", "name": "fuse(r:p1rdt7576-p1rdt8151)p1r_18146", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c794942-d5ce-481f-9c6a-563a2180a4ba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75a31fa2-4df8-418a-a215-d0d450ced9a3"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "f0e0af75-4597-4f6c-930a-4e193179b902", "name": "fuse(r:p1rdt8151-p1rdt8155)p1r_18147", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c794942-d5ce-481f-9c6a-563a2180a4ba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0a6628e-afc1-4daf-8a29-7626ac2aa5dd"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "fb5f1e22-94af-4dc6-89b5-0b586358c8cb", "name": "fuse(r:p1rdt8405-p1rdt8445)p1r_18212", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60829dab-c129-4017-961a-81435d8afa93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8c69243-872f-4e25-9d03-82692bbf8779"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "70b85fee-d939-41de-9968-944ff2b25094", "name": "fuse(r:p1rdt8414-p1rdt8456)p1r_18215", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b48f78d-1092-4536-bfb3-029da6a70dff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34054ef8-8942-4471-ac14-43c6a37e5a16"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "85454510-f466-49d9-93d2-1381c0acd28a", "name": "fuse(r:p1rdt6347-p1rdt8470)p1r_18224", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "442de065-9e2a-4ff8-9100-1298d3fe0f6f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6163371c-55ef-4900-a3ef-2e4e8fc2894a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "d0487dc6-e327-4fb9-8124-bce8e04cfc95", "name": "fuse(r:p1rdt7268-p1rdt8470)p1r_18225", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "442de065-9e2a-4ff8-9100-1298d3fe0f6f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6225b33-2abc-4f77-9d65-459794f56353"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "4a4594e8-f914-4990-ba21-6c90a130e917", "name": "fuse(r:p1rdt8901-p1rdt8902)p1r_18292", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f44ec9b-338a-4ae1-a26b-26422f218c13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d21061fa-1011-44f7-8a20-26fcf0550f52"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "861d64ae-aba6-4135-a3ca-f177438722a2"}}}}, {"uuid": "c53f224c-161b-4771-a189-43944175e441", "name": "fuse(r:p1rdt8902-p1rdt9377)p1r_18293", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f44ec9b-338a-4ae1-a26b-26422f218c13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43c862de-b014-4b24-8b34-54dae6edcf5a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "861d64ae-aba6-4135-a3ca-f177438722a2"}}}}, {"uuid": "6f8f40b9-00fa-445b-a260-2f2b7058d7fb", "name": "fuse(r:p1rdt6581-p1rdt9084)p1r_18331", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4251587d-600f-40a0-9aec-229fb2e3f2df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6114624f-81c8-4d9c-8f9a-3ab73158596e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "198bb22e-539d-4ad2-99eb-c99330a282b0", "name": "fuse(r:p1rdt9076-p1rdt9084)p1r_18332", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4251587d-600f-40a0-9aec-229fb2e3f2df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12b4dc99-fe50-457c-90aa-48a2fb19ebf1"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "db412f85-aaee-44e6-b2f7-6c05006c4a3f", "name": "fuse(r:p1rdt7790-p1rdt9090)p1r_18334", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52c72b52-1c6c-46f6-adbe-1054eb233c20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15a7847f-aa96-4206-b4c6-422802f4e0a6"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "e8b8932b-1bea-473d-b138-d323af891be4", "name": "fuse(r:p1rdt9090-p1rdt9091)p1r_18335", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "52c72b52-1c6c-46f6-adbe-1054eb233c20"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf719d10-8168-4d80-894e-1b1516f033e8"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "36b7e8e3-1a5f-4604-9ffe-b88b6a71ea45", "name": "fuse(r:p1rdt6226-p1rdt9333)p1r_18385", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0da91bf8-b687-47df-a7dc-41e6166fd667"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f6d3fab-3b83-40c9-85c4-cfeddd0d317a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "3bf77ce1-4f77-4f4c-902e-9b4293967914", "name": "fuse(r:p1rdt9469-p1rdt9470)p1r_18407", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3fd32c7-2866-4699-93a8-dd3a9997d349"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5f6a2ec-3ddd-4ba7-9c55-88b4d82e7735"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "7d4a8786-91d9-4845-8fe5-8e8f350b4a94", "name": "fuse(r:p1rdt5730-p1rdt9479)p1r_18410", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b006c3-79f8-4a27-b76a-d1b458ff2a21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e07d8bc1-2f8a-4067-a2a7-b903dd042ce3"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "8b1e7929-00be-4710-9892-83b9f936f05c", "name": "fuse(r:p1rdt5840-p1rdt9479)p1r_18411", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9b006c3-79f8-4a27-b76a-d1b458ff2a21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7f9286b-4209-402a-a365-1d27da4efb75"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "2c304709-0eb6-47d1-aa82-ab4b517d007e", "name": "recloser_disswitch(r:p1rdt8802-p1rdt9413)p1r_20691", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f750e531-5ade-40a9-9bb0-042220ce9807"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "401576cc-4ad6-42cd-bf1c-4022da720711"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "140f67fe-0cf8-45a3-8e1d-7cd225dab6f1"}}}}, {"uuid": "84d72fc4-99d1-4474-99ef-ab56621f28e6", "name": "goab_disswitch(r:p1rdt5236-p1rdt5342)p1r_20760", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c8f9ea6-06fb-4fd0-8629-ceea4f32189f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9bbfae79-a578-4ff2-b622-3dddd9859ac8"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "1848ee60-41cc-4072-ae7a-8f2e890e75ff", "name": "goab_disswitch(r:p1rdt6531-p1rdt7307)p1r_20862", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "385eabe4-8c8e-4354-96ec-931e6c25574d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8431ef4c-78dd-4a39-b15a-95818cfe1d86"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "60e69ce7-f8f6-4852-ae1e-694ae07f37f5", "name": "recloser_disswitch(r:p1rdt8405-p1rdt9413)p1r_20975", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f750e531-5ade-40a9-9bb0-042220ce9807"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16ecb938-cd0c-4be5-a915-be0d84d351f2"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "140f67fe-0cf8-45a3-8e1d-7cd225dab6f1"}}}}, {"uuid": "bb69f156-d7c0-40a5-87e3-b6c622faea56", "name": "goab_disswitch(r:p1rdt6208-p1rdt8805)p1r_20999", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3444af6b-f9d4-4229-b6b2-2114300c3f94"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "89f0c671-9d27-4dec-bd37-dc6c56f07e5d"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "b7056dc9-d1ea-4fc2-a609-6d09d60d3fac", "name": "goab_disswitch(r:p1rdt6517-p1rdt6523)p1r_21014", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b540c710-395d-4a35-8dc3-59d37609df09"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "608945f2-9b19-43bc-83d9-0fe8787b06b4"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "c505d68e-64f2-48ac-afb2-f29694bbaa79", "name": "disswitch(r:p1rdt5195-p1rdt5202)p1r_21153", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97e4f179-9d60-4183-8326-eb0ab98a53eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "227d848c-cddc-4561-996b-f8f7a60a5a89"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "ee8a464c-5fc6-41d0-9c41-36add8ffa204", "name": "goab_disswitch(r:p1rdt8160-p1rdt8161)p1r_21295", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25946c74-15c2-412c-baed-8de5f7aecf98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8ecbd5b-6db5-44a0-b2a8-0233d4eb5b20"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "0799b34e-32a2-4275-b73b-5d5b98a2674b", "name": "goab_disswitch(r:p1rdt4980-p1rdt5183)p1r_21308", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ddb0629-4947-47ca-83f9-9b7c073db235"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35487e15-57cb-4e19-bef7-49074e5eb9ee"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "ca277d25-50a6-4bf9-becf-59896b3145c3", "name": "l(r:p1rdt6501-p1rdt9468)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e4fd2ed-daa1-4a22-936f-8d51ee928d99"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "edf27f1d-b486-434e-92be-963bdeb26090"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "40a26197-da2a-4e22-a50a-3922efd7762c"}}}}, {"uuid": "22c44cd1-4a06-4e8d-9f99-9f622360b34c", "name": "l(r:p1rdt6501-p1rdt9468)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "edf27f1d-b486-434e-92be-963bdeb26090"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b5695dd-714e-4de1-a63a-f142ff0460e1"}}}], "length": {"value": 0.907254, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e3949704-59de-4ac0-a856-a028f2766fb2", "name": "l(r:p1rdt8902-p1rdt9377)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32e86968-974e-4bcc-b562-1d4209771cf0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e62ba05d-920f-4f55-b1c6-3aa078e0073d"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "40a26197-da2a-4e22-a50a-3922efd7762c"}}}}, {"uuid": "f111d805-c7d0-4e6b-beee-74b482cec4f6", "name": "l(r:p1rdt8902-p1rdt9377)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e62ba05d-920f-4f55-b1c6-3aa078e0073d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61972a50-ce24-4ec1-8535-402665b55a55"}}}], "length": {"value": 1.557306, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3a055c24-acdd-4c3d-8cc6-653f0d8be826", "name": "l(r:p1rdt5195-p1rdt5653)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fbc486eb-4f08-4602-a101-1298d4a46b32"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ccc9dcb-3a72-4f11-9bcf-e3a7f1a21985"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "40a26197-da2a-4e22-a50a-3922efd7762c"}}}}, {"uuid": "313717c1-fa7c-4f6e-b27e-12c06e71e69e", "name": "l(r:p1rdt5195-p1rdt5653)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ccc9dcb-3a72-4f11-9bcf-e3a7f1a21985"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "769c14db-ac3f-438d-9f7d-c7eb2d3074b5"}}}], "length": {"value": 0.915894, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4399bb4b-ec3f-463a-b5d0-16570e8eb9b9", "name": "l(r:p1rdt28lv-p1rlv51)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b3c997d-cd47-439c-aeb9-326e12c2b869"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ccef6af-4bf6-44dc-b292-2bf9503a374a"}}}], "length": {"value": 0.0198886, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4aaad3fe-4de0-4afb-8264-3875d74a560e", "name": "l(r:p1rdt28lv-p1rlv53)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b3c997d-cd47-439c-aeb9-326e12c2b869"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3c62646-6132-41ef-ba14-a06789885cd5"}}}], "length": {"value": 0.0198886, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d32a111a-c62d-4052-bf39-48c43dab30fb", "name": "l(r:p1rdt29lv-p1rlv52)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61fc3980-6aa4-415c-91c1-10d32c7c359c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fec0a162-4b0c-4577-b878-8dbc7c9935fc"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "537e8b73-0d40-4f17-a28d-0aae6b098e14", "name": "l(r:p1rdt30lv-p1rlv62)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d2be3b5-dbfc-4099-af9a-96368e60fe23"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "346dad85-3bf8-41a6-97ea-6b3b40a7f22e"}}}], "length": {"value": 0.028845, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "85b7ab92-76f2-4b11-843c-08ecd9d88d3d", "name": "l(r:p1rdm56-p1rlv54)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c89ec162-cda3-4c40-8833-3fff085538ba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20010301-32ce-4cc0-ab59-04ef3bcd35d7"}}}], "length": {"value": 0.0170492, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ddaa35ee-6a95-4aea-8dd8-4c94f1fce2c3", "name": "l(r:p1rdm56-p1rdt30lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d2be3b5-dbfc-4099-af9a-96368e60fe23"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c89ec162-cda3-4c40-8833-3fff085538ba"}}}], "length": {"value": 0.0189193, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9b7fb251-9269-4d78-8c55-47059d037541", "name": "l(r:p1rdm58-p1rlv55)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59ff3c1b-38f4-4a33-86fa-e956951c0f2c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36bdbc4e-edfa-425a-8e4c-e6123b567555"}}}], "length": {"value": 0.013887, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "859a2d9c-f5ee-4913-8ea2-6fdfbcfab2b9", "name": "l(r:p1rdm60-p1rlv152)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f678ceb4-b717-44a5-9db9-f698bece6935"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25b891ce-797a-4a4d-b664-4225fba806c4"}}}], "length": {"value": 0.0140747, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "aa7cc74b-1797-4884-9885-e3500e2380d9", "name": "l(r:p1rdm58-p1rdm60)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59ff3c1b-38f4-4a33-86fa-e956951c0f2c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f678ceb4-b717-44a5-9db9-f698bece6935"}}}], "length": {"value": 0.0566856, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7fb3cf19-7676-4fc4-ab81-0e769d75d414", "name": "l(r:p1rdm58-p1rdt31lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3510eedd-535c-4e58-b81e-c5ec09030479"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59ff3c1b-38f4-4a33-86fa-e956951c0f2c"}}}], "length": {"value": 0.0140094, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d9c6db05-7bc3-4ad3-84d9-f60e07fa7a5f", "name": "l(r:p1rdm59-p1rlv58)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a0a4841-bf31-4498-98d9-115cc159981c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a32ee184-f677-4333-b7ee-7bc30ab41467"}}}], "length": {"value": 0.0220532, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "19418b76-199d-4da4-a457-d31bd2cc8bd2", "name": "l(r:p1rdm59-p1rdt31lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3510eedd-535c-4e58-b81e-c5ec09030479"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a0a4841-bf31-4498-98d9-115cc159981c"}}}], "length": {"value": 0.0494128, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8b247c95-6202-4fe5-940d-4492e1bffb6c", "name": "l(r:p1rdt32lv-p1rlv414)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e374d6d6-1e75-4808-b65a-c7033e1bd528"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec2c1edd-78b1-4436-85cc-2fbc7d880b87"}}}], "length": {"value": 0.00981453, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f0dff6bc-98c3-4316-b25d-c48ba2181493", "name": "l(r:p1rdm61-p1rlv56)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cef7aa37-7ca0-4130-9bcd-1804a811245a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4694811a-ba43-4c78-b957-5209b1d961e2"}}}], "length": {"value": 0.0329346, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3bbc54a5-ff57-420e-b9f4-554e9a130e80", "name": "l(r:p1rdm61-p1rdt32lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e374d6d6-1e75-4808-b65a-c7033e1bd528"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cef7aa37-7ca0-4130-9bcd-1804a811245a"}}}], "length": {"value": 0.0318291, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6fc81b07-6ca8-4ea4-8296-3a5318abe131", "name": "l(r:p1rdt33lv-p1rlv170)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "065c8583-45e5-466c-b4c0-1c66bf970abe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f7dbd18-1cbe-49d3-b490-3c46cf8e37f1"}}}], "length": {"value": 0.0380059, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "16b7dcf9-eccc-4d50-bf94-8699ecae0e2f", "name": "l(r:p1rdm63-p1rlv57)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0538c66-18d7-440e-9efd-6b2945d50f2b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "925cb3b7-4ced-4a36-913f-e6851ed79b98"}}}], "length": {"value": 0.030867800000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2bdd73c1-d6c6-46df-925e-e5b975ebcf7e", "name": "l(r:p1rdm63-p1rdt33lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "065c8583-45e5-466c-b4c0-1c66bf970abe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0538c66-18d7-440e-9efd-6b2945d50f2b"}}}], "length": {"value": 0.0345517, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "83b76af1-5305-4dbc-bb4d-1ae26fa9de1d", "name": "l(r:p1rdm64-p1rlv61)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfa2eaff-b163-46ce-b6e5-516680d39bc3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d22bf2f5-74cc-47c7-ae3b-410fba27c113"}}}], "length": {"value": 0.0241386, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3898954b-b312-40ab-ac32-628c8dce2ca0", "name": "l(r:p1rdm64-p1rdt33lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "065c8583-45e5-466c-b4c0-1c66bf970abe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfa2eaff-b163-46ce-b6e5-516680d39bc3"}}}], "length": {"value": 0.0177518, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "02917748-21d7-4d1d-ba3e-9a59a7f04498", "name": "l(r:p1rdm66-p1rlv59)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72ee0111-4849-4280-b3c9-c0627d1a6c09"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b80bdb24-4bbf-4a57-bd5f-6a5ec9d484dd"}}}], "length": {"value": 0.024402100000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a261116f-a80b-4209-9176-cbc942356177", "name": "l(r:p1rdm66-p1rdt34lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "553a6868-acec-4492-a52d-5aa08414c612"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72ee0111-4849-4280-b3c9-c0627d1a6c09"}}}], "length": {"value": 0.0174345, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "efad20b9-c489-41bc-9b18-f645e0471962", "name": "l(r:p1rdm67-p1rlv67)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "713c1538-ceb4-46df-a996-6c591c0f8e40"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64a67ed2-a563-4378-b6ac-d9a95339e862"}}}], "length": {"value": 0.0188395, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "068b2a22-12d1-4431-9876-767c11d1380a", "name": "l(r:p1rdm67-p1rdt34lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "553a6868-acec-4492-a52d-5aa08414c612"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "713c1538-ceb4-46df-a996-6c591c0f8e40"}}}], "length": {"value": 0.009885930000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "57f5dec5-fde4-48bd-927b-f6e8e3ee8902", "name": "l(r:p1rdt35lv-p1rlv60)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f98cc066-fca3-4489-9770-047caee3e742"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7eb0d1e8-f85e-493e-b69b-26437fdb8ad9"}}}], "length": {"value": 0.0469606, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "dab845c7-99b1-4cc4-8b7b-5a2a0dd8bc4c", "name": "l(r:p1rdm69-p1rlv65)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23861598-ab3c-4648-9de9-3ee4316f2cb4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e00fd9b-92b3-49c4-bcc2-957b9d2c7bad"}}}], "length": {"value": 0.0500401, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "46a3c80f-7d6c-48a5-8c7e-9fbd9a1b6494", "name": "l(r:p1rdm69-p1rdt35lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f98cc066-fca3-4489-9770-047caee3e742"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23861598-ab3c-4648-9de9-3ee4316f2cb4"}}}], "length": {"value": 0.0188806, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9b42fd7d-449c-4d4e-adea-0857666843b0", "name": "l(r:p1rdt36lv-p1rlv63)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a4fb658-c3ba-428a-82bf-b38ae68dd908"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8300f90c-9a3b-400d-af04-072125dce84f"}}}], "length": {"value": 0.0205644, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b4da0dcf-1635-44fc-9cfa-33fecce7b0c4", "name": "l(r:p1rdm71-p1rlv64)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "074f23bd-2fb2-4480-ae4b-f1c1f754613e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5efd07ee-012a-40a4-97bb-07c1a5ed898c"}}}], "length": {"value": 0.0292333, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6bf40a82-f525-451a-b200-2331216a8321", "name": "l(r:p1rdm72-p1rlv162)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "590e467f-47a6-4c7e-ae3a-83cec8dd87e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3fcd1ee-e6e0-4ca3-aacf-cc527b07482a"}}}], "length": {"value": 0.0254773, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "11fdc903-3137-4c9b-940d-6dfaefc83a72", "name": "l(r:p1rdm71-p1rdm72)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "074f23bd-2fb2-4480-ae4b-f1c1f754613e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "590e467f-47a6-4c7e-ae3a-83cec8dd87e3"}}}], "length": {"value": 0.0457287, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1bba3325-6f85-4fd1-8d29-a1bf18d1c001", "name": "l(r:p1rdm71-p1rdt37lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90a16370-67f7-4abd-992c-990d1eb8f17e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "074f23bd-2fb2-4480-ae4b-f1c1f754613e"}}}], "length": {"value": 0.0378897, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1e35ea63-0b7a-4e0b-b5fa-533a1e06f848", "name": "l(r:p1rdm73-p1rlv457)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35807695-5d6d-4544-a748-a96c56b705d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6278f6ee-7332-4de8-9d2c-83bb637f489f"}}}], "length": {"value": 0.020988, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a802ba01-a073-46dc-a10c-aa18ea2dbc0e", "name": "l(r:p1rdm73-p1rdt37lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90a16370-67f7-4abd-992c-990d1eb8f17e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35807695-5d6d-4544-a748-a96c56b705d1"}}}], "length": {"value": 0.0568504, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "70ad305b-4b65-4e83-8e65-943e35a8510a", "name": "l(r:p1rdm74-p1rlv66)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "352f8404-f923-468a-92a5-1be2f82ffb97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e90eb8a2-5db0-4861-96ef-a6991a0386eb"}}}], "length": {"value": 0.0137711, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5adb5955-448c-40e5-95ec-8933d9be1689", "name": "l(r:p1rdm74-p1rdt38lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "752aca33-7682-4e8c-a8b1-624467e02958"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "352f8404-f923-468a-92a5-1be2f82ffb97"}}}], "length": {"value": 0.0186134, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "851de1c3-1505-4685-909f-6eddfe850ab2", "name": "l(r:p1rdm75-p1rlv68)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2332f175-22ca-4894-b63d-246f5c11c572"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c22aa2c8-a6fc-4b27-a875-e07e3f50ecac"}}}], "length": {"value": 0.0220855, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "eb01a68d-63ea-47e1-a68a-7afd7773560d", "name": "l(r:p1rdm75-p1rdt38lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "752aca33-7682-4e8c-a8b1-624467e02958"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2332f175-22ca-4894-b63d-246f5c11c572"}}}], "length": {"value": 0.0568453, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c0d8734c-4318-43b0-9e1e-c11ab3c1271b", "name": "l(r:p1rdm76-p1rlv69)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "131099af-6f69-4531-bebf-e457ff5d7624"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "876ffb0b-f33c-45b2-a085-7b34103ecffc"}}}], "length": {"value": 0.0355524, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "145e3aee-da52-4de2-a9a0-0cf95e1a2b11", "name": "l(r:p1rdm76-p1rdt39lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "623ec6b4-cb70-4437-9d79-5ec577bc3199"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "131099af-6f69-4531-bebf-e457ff5d7624"}}}], "length": {"value": 0.0177535, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "06a16ec9-6153-49da-a2be-542e268a7b4b", "name": "l(r:p1rdm77-p1rlv70)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a909c826-1682-47f0-926c-0a67c9ff2a3a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e53e7714-06d1-4f85-89c5-f152629e8ab7"}}}], "length": {"value": 0.0326608, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f396975a-7f86-4dd3-ad16-b797849c3c9b", "name": "l(r:p1rdm77-p1rdt39lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "623ec6b4-cb70-4437-9d79-5ec577bc3199"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a909c826-1682-47f0-926c-0a67c9ff2a3a"}}}], "length": {"value": 0.0177617, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5a53052c-73d6-4ee8-a0c2-559a73722330", "name": "l(r:p1rdt40lv-p1rlv143)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d08444c-79a3-4ba0-8c69-1855a600dea0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "46cd88d0-b2c4-492a-af3d-d9ae886d0089"}}}], "length": {"value": 0.016125500000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "482a0e0c-58d8-4958-aba7-344577c6f03f", "name": "l(r:p1rdm78-p1rlv71)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "435b1814-b0a6-40e3-a446-efe5b7fce133"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d7791de-0cf6-4901-8b95-2d67870f09f5"}}}], "length": {"value": 0.025679000000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2656656a-d2e7-49e3-9554-4cfd0e1b3ca5", "name": "l(r:p1rdm78-p1rdt40lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d08444c-79a3-4ba0-8c69-1855a600dea0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "435b1814-b0a6-40e3-a446-efe5b7fce133"}}}], "length": {"value": 0.0167754, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f87e81cc-c8a8-40ae-8e3f-0ac8561cdefe", "name": "l(r:p1rdt41lv-p1rlv72)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "793d0bf4-4d9f-4df4-bc95-d528dd7d31d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc710fc3-ae5f-478e-997b-85467db7c93c"}}}], "length": {"value": 0.02597, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e52746d2-07d5-4974-a61e-ff8b224c2504", "name": "l(r:p1rdt41lv-p1rlv88)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "793d0bf4-4d9f-4df4-bc95-d528dd7d31d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "188047cd-3f14-4240-91fe-30113d48152b"}}}], "length": {"value": 0.00984838, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6b64c3a9-ba1b-4cdf-ad7f-e5db328b835d", "name": "l(r:p1rdt42lv-p1rlv86)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8fb27dc9-b404-49d1-84dd-0cde418b037d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "540e0121-fc39-4c2c-9fbc-012c020f5994"}}}], "length": {"value": 0.0169027, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f58b52b9-f373-436c-9298-a94f37865466", "name": "l(r:p1rdm82-p1rlv73)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5f4300c-037f-42b5-a390-31ec1e8396b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f4e2991c-1404-44da-bbb5-5a2ebc43bde4"}}}], "length": {"value": 0.025469700000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fd2626d9-6e6e-40a6-b779-ae761e65eaac", "name": "l(r:p1rdm86-p1rlv108)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5696ebea-257d-4cc1-9ae4-61c98563b706"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "afc70b80-ab76-440c-b05b-149458051675"}}}], "length": {"value": 0.05240000000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4cd09994-2b8e-4ac2-b56f-ee68addc1a41", "name": "l(r:p1rdm82-p1rdm86)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5f4300c-037f-42b5-a390-31ec1e8396b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5696ebea-257d-4cc1-9ae4-61c98563b706"}}}], "length": {"value": 0.0153424, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7708cca7-aa53-4b77-befd-c39e45b72c32", "name": "l(r:p1rdm82-p1rdt42lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8fb27dc9-b404-49d1-84dd-0cde418b037d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5f4300c-037f-42b5-a390-31ec1e8396b3"}}}], "length": {"value": 0.0153436, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e84c77e4-d941-4bb3-8e2f-0af560052a45", "name": "l(r:p1rdm83-p1rlv75)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49a07eb5-9c9b-479c-a345-b09f72725a21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ef51371-3fa2-400a-a2b4-3afa97ff2419"}}}], "length": {"value": 0.0103792, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "927bf580-0b67-4304-a620-9bc0dbd749e8", "name": "l(r:p1rdm83-p1rlv130)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49a07eb5-9c9b-479c-a345-b09f72725a21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5c96953-6710-4765-b5bd-4359e03e4c63"}}}], "length": {"value": 0.0354711, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "5634d407-bc77-4db0-b887-faa3d8d89dfd", "name": "l(r:p1rdm84-p1rlv79)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae45c08d-f629-4ff9-9c23-838b6e34da88"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4dd2283-6100-48ce-b4bc-0e37b7b4e409"}}}], "length": {"value": 0.0190078, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ead30048-de23-480f-aaa4-ed9fe5b1fc46", "name": "l(r:p1rdm87-p1rlv115)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d93360fa-3106-4444-9488-e73c6997ab71"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "919a48e8-b378-4dd5-8e33-a2602fb58bc0"}}}], "length": {"value": 0.0121631, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9d97061e-2727-4ac2-b9bf-80ebbfc55484", "name": "l(r:p1rdm84-p1rdm87)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae45c08d-f629-4ff9-9c23-838b6e34da88"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d93360fa-3106-4444-9488-e73c6997ab71"}}}], "length": {"value": 0.0078607, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "53544628-331d-4655-91a4-0552645c049b", "name": "l(r:p1rdm83-p1rdm84)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49a07eb5-9c9b-479c-a345-b09f72725a21"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae45c08d-f629-4ff9-9c23-838b6e34da88"}}}], "length": {"value": 0.0149995, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1ac77898-6235-494c-b7f1-3d2c55ee09bb", "name": "l(r:p1rdm83-p1rdt42lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8fb27dc9-b404-49d1-84dd-0cde418b037d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49a07eb5-9c9b-479c-a345-b09f72725a21"}}}], "length": {"value": 0.0149938, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d4818ca2-9988-4682-8047-75b4f8e1b705", "name": "l(r:p1rdm90-p1rlv117)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b812c54c-1689-47cf-beba-55faea943380"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e6de569-7f61-439e-a402-850c4f071ab3"}}}], "length": {"value": 0.0134175, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "41a7ab78-9dfe-4430-89b0-f3ba5c13ff28", "name": "l(r:p1rdm90-p1rdt43lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "274aa0ec-f229-454c-b52d-23130bacb97e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b812c54c-1689-47cf-beba-55faea943380"}}}], "length": {"value": 0.0542235, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6bfac725-d1e2-41cf-ad2e-86634eae8994", "name": "l(r:p1rdm91-p1rlv137)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c82df28-72fa-4cf0-a844-8a6bf90e548b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54ca5205-5b71-42f2-8e24-c24f768a7a5c"}}}], "length": {"value": 0.0263424, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c4bc0a7f-44b6-4f0d-976c-999ec209e06f", "name": "l(r:p1rdm89-p1rlv74)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acbf36c3-9c53-417f-98c1-fa1b5d4b60f4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5861410e-9d6d-423e-b967-2f2af65610b8"}}}], "length": {"value": 0.0187311, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "83961bfa-b775-448b-8caf-405871623580", "name": "l(r:p1rdm89-p1rdm91)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c82df28-72fa-4cf0-a844-8a6bf90e548b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acbf36c3-9c53-417f-98c1-fa1b5d4b60f4"}}}], "length": {"value": 0.0145778, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d8f254e6-7113-400b-92d5-364565ba1e80", "name": "l(r:p1rdm91-p1rdt43lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "274aa0ec-f229-454c-b52d-23130bacb97e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c82df28-72fa-4cf0-a844-8a6bf90e548b"}}}], "length": {"value": 0.0145786, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "db357783-b1b2-4ffd-aca8-8ab881b6c351", "name": "l(r:p1rdt44lv-p1rlv76)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c813f8a2-226b-431d-a41a-195cf5e8b01a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3354497f-6de7-405d-9fca-a9c77463dc27"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "82e7c04e-ab13-4355-9b05-434f456065ad", "name": "l(r:p1rdm93-p1rlv77)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5151d03-c8b3-41f2-a2cd-743aa8ea0fea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f88a22a3-7e6c-4fc5-a8f4-a08cdaa3f5d6"}}}], "length": {"value": 0.0172005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ce7f90cf-c8da-460b-8111-0ea157b77973", "name": "l(r:p1rdm94-p1rlv119)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4dece5f0-ab6c-40ed-9ec6-0b1377d19e78"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee33d90b-2f70-4c9d-863d-6486b95280b8"}}}], "length": {"value": 0.0199779, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bd47d45f-500c-4c3d-8678-51a92d9023ea", "name": "l(r:p1rdm93-p1rdm94)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5151d03-c8b3-41f2-a2cd-743aa8ea0fea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4dece5f0-ab6c-40ed-9ec6-0b1377d19e78"}}}], "length": {"value": 0.0237669, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e1298125-2403-434a-b2db-9f772bc576f3", "name": "l(r:p1rdm93-p1rdt45lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e276abc-bb27-47e4-9de8-adaccbf964dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5151d03-c8b3-41f2-a2cd-743aa8ea0fea"}}}], "length": {"value": 0.0199888, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "96d5897f-f166-4bb2-8b66-3b7ba676cfe2", "name": "l(r:p1rdm95-p1rlv132)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a363b9b6-b80f-42cf-942e-17e723376ae6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41960437-e2e6-4746-89c2-81c81602ca1b"}}}], "length": {"value": 0.027088, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "79f574f4-b9a5-43f9-ab40-01e7afbc43b6", "name": "l(r:p1rdm95-p1rdt45lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e276abc-bb27-47e4-9de8-adaccbf964dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a363b9b6-b80f-42cf-942e-17e723376ae6"}}}], "length": {"value": 0.0399682, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "93d914a2-0ec3-414d-9502-25ee2a4943eb", "name": "l(r:p1rdm96-p1rlv78)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e93e7ed-6686-4fb2-8410-867f2cdbdab2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ae76f058-b79a-4c0f-90be-f9cd7a02bcfc"}}}], "length": {"value": 0.032544800000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3e22d8ca-5f4b-48ed-afc3-1da29b5dce45", "name": "l(r:p1rdm97-p1rlv87)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdd576f2-a7e2-46eb-b2b0-818c4a97e694"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "46ee0e6c-daf7-4412-94a7-5332a6a97656"}}}], "length": {"value": 0.029464900000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e72d832f-a10c-4a41-bce6-db90e6a066d2", "name": "l(r:p1rdm96-p1rdm97)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e93e7ed-6686-4fb2-8410-867f2cdbdab2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fdd576f2-a7e2-46eb-b2b0-818c4a97e694"}}}], "length": {"value": 0.0168832, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8cfe93c7-253e-4b6b-b392-aea42b09d08e", "name": "l(r:p1rdm96-p1rdt46lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aacdcb46-43e3-4147-ac25-3a9c1223e13a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e93e7ed-6686-4fb2-8410-867f2cdbdab2"}}}], "length": {"value": 0.018235, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "78991428-108e-4d6c-9398-41e4ca9a49db", "name": "l(r:p1rdm98-p1rlv138)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70024d6c-94dd-4367-aeec-92d4bc5eec04"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea9e5f8c-8477-403c-9d3a-911c4e5ab5c8"}}}], "length": {"value": 0.0236773, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c3c52273-2722-4a97-bd10-8e3dd59685c4", "name": "l(r:p1rdm98-p1rdt46lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aacdcb46-43e3-4147-ac25-3a9c1223e13a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70024d6c-94dd-4367-aeec-92d4bc5eec04"}}}], "length": {"value": 0.0547245, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d216af78-c172-4a19-a303-41195ec88d64", "name": "l(r:p1rdt47lv-p1rlv80)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f031530a-b3fc-4f8e-b0ac-139009d1256c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab7e1b4a-f8ec-4211-b7a0-d7f9057f576a"}}}], "length": {"value": 0.0117312, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "97d48ab3-ae67-4bb4-9933-c573d3b1b708", "name": "l(r:p1rdt47lv-p1rlv92)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f031530a-b3fc-4f8e-b0ac-139009d1256c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db8f484a-94d5-4d20-8ebf-6708b1601a0d"}}}], "length": {"value": 0.0191133, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "496ae067-3834-4768-96cc-4f91d6de96f4", "name": "l(r:p1rdt48lv-p1rlv81)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f1790fe-a399-46e3-b9e3-5979837777ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef92e40c-fe3c-4f7f-b844-884e1079e491"}}}], "length": {"value": 0.0151262, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "42788906-ee7c-4cb5-8863-6cdb7c3c583f", "name": "l(r:p1rdt48lv-p1rlv120)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f1790fe-a399-46e3-b9e3-5979837777ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a02925cd-7c5b-475f-9e91-30d639bb3c33"}}}], "length": {"value": 0.018014, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e6aee435-bc57-4b28-884d-c7734e4c64c1", "name": "l(r:p1rdm103-p1rlv122)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd7286c0-4c57-435f-bed2-fd9a927de8cc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b02739e-d082-4c54-8deb-8ccc83ab82ab"}}}], "length": {"value": 0.0117766, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "80537724-8dad-4e90-9c0f-536cfeb4f9aa", "name": "l(r:p1rdm103-p1rdt48lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f1790fe-a399-46e3-b9e3-5979837777ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd7286c0-4c57-435f-bed2-fd9a927de8cc"}}}], "length": {"value": 0.0197485, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0cac18f1-d0e4-45c0-9221-b52524ca2f6d", "name": "l(r:p1rdt49lv-p1rlv146)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e5bcc7e-f35c-4bbf-a7ff-a82817488b11"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da2538bd-189b-4699-823b-ed459d94b422"}}}], "length": {"value": 0.0323291, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "13eb61ae-13e2-4fcc-a1a7-33a49f742fef", "name": "l(r:p1rdm104-p1rlv82)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2409ced2-7817-40af-951f-33d725e9d75a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3ddd704-2530-4392-8e9e-06e047b12f41"}}}], "length": {"value": 0.018038, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0bf98212-8412-4b8c-8960-9f693eb62909", "name": "l(r:p1rdm104-p1rdt49lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e5bcc7e-f35c-4bbf-a7ff-a82817488b11"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2409ced2-7817-40af-951f-33d725e9d75a"}}}], "length": {"value": 0.0322986, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8527ab91-ca01-4884-958f-9bf6cadfb78d", "name": "l(r:p1rdm105-p1rlv107)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8385921-c183-4c26-bc99-bf5f0364c18b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "096e92a6-ea34-435e-a059-57d5234e1654"}}}], "length": {"value": 0.0143529, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "477a74e8-32b9-4d2f-8c62-4a8e287e6159", "name": "l(r:p1rdm105-p1rdt49lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e5bcc7e-f35c-4bbf-a7ff-a82817488b11"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8385921-c183-4c26-bc99-bf5f0364c18b"}}}], "length": {"value": 0.025904, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "eeb8dff2-6d0f-4edd-ab69-3e388cb798e4", "name": "l(r:p1rdt50lv-p1rlv127)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8208c617-caa9-46a5-b28a-8a5b0d9898a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ae7b1fe-08c4-4848-867e-e2426a325a99"}}}], "length": {"value": 0.0188957, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b4256583-e043-485c-b1d9-d6895fd573e8", "name": "l(r:p1rdm107-p1rlv83)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7948c980-abf7-4357-9ff8-4be9122a3167"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24c3e8d8-1520-4a05-84af-a70da6140b4d"}}}], "length": {"value": 0.02164, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "312ba1b5-d276-4196-b974-e562abef042c", "name": "l(r:p1rdm107-p1rlv123)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7948c980-abf7-4357-9ff8-4be9122a3167"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6184fe8d-ae60-426a-8c0c-a3cc56c5b67e"}}}], "length": {"value": 0.0223678, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ee3cd3d5-6ad3-46f8-be26-c622fe63b8e3", "name": "l(r:p1rdm107-p1rdt50lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8208c617-caa9-46a5-b28a-8a5b0d9898a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7948c980-abf7-4357-9ff8-4be9122a3167"}}}], "length": {"value": 0.01639, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d826c2fb-edda-469a-8669-c708580b5496", "name": "l(r:p1rdm110-p1rlv135)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2deeb6a-3ea7-44d9-9ee0-b013733dadc4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbdefe7a-517b-495b-88b8-dcf15a9429ff"}}}], "length": {"value": 0.0127473, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b029d869-0f98-49a8-ae56-7d0d5762a52f", "name": "l(r:p1rdm110-p1rdt50lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8208c617-caa9-46a5-b28a-8a5b0d9898a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2deeb6a-3ea7-44d9-9ee0-b013733dadc4"}}}], "length": {"value": 0.0164, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "205b7f88-30e3-477c-8222-63e49c3e5d9f", "name": "l(r:p1rdt51lv-p1rlv84)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09d7f030-a9b4-4705-82af-6cf140ba64d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "55e7538f-4bde-4810-a237-ac0cad7ba805"}}}], "length": {"value": 0.0456569, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "239e52d2-6f1c-4541-b593-743f536d2902", "name": "l(r:p1rdt51lv-p1rlv93)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09d7f030-a9b4-4705-82af-6cf140ba64d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0060c029-188f-4725-a935-8d0d9cc892f7"}}}], "length": {"value": 0.0305916, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a60d8329-112d-4656-b827-353773776f11", "name": "l(r:p1rdm113-p1rlv85)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5dd2d9f-42d5-48c4-b1e1-34ae6aa555df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcc52dd9-bacb-4e49-a057-d3747f89a7f7"}}}], "length": {"value": 0.0311927, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "5f3de303-599b-4841-99bd-cbb5d215b96a", "name": "l(r:p1rdm114-p1rlv91)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f42789f3-35c3-4d0d-adda-2044adce92c0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a1f01bc-d1f1-4d92-b1e2-1f8223624c52"}}}], "length": {"value": 0.0125623, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d83ba6fd-6457-4dda-a12d-dd5e09239ede", "name": "l(r:p1rdm113-p1rdm114)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5dd2d9f-42d5-48c4-b1e1-34ae6aa555df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f42789f3-35c3-4d0d-adda-2044adce92c0"}}}], "length": {"value": 0.0299732, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4d3d0323-36de-40d0-8acd-e15ce914b8e3", "name": "l(r:p1rdm113-p1rdt52lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c70a7331-8c41-4370-b053-3eae432d52ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5dd2d9f-42d5-48c4-b1e1-34ae6aa555df"}}}], "length": {"value": 0.0479351, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ebaf4901-4748-4e10-9bb6-f80772e1827b", "name": "l(r:p1rdm115-p1rlv94)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2d46cd2-9caf-47a7-b134-a29fccd91b9c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db2d4080-1f43-47a3-9f3a-e25d1e4f5076"}}}], "length": {"value": 0.0260186, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "55a80fa5-3bf1-418a-ad5c-7afa1fdf1e6c", "name": "l(r:p1rdm115-p1rlv103)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2d46cd2-9caf-47a7-b134-a29fccd91b9c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85afc796-3fe5-4027-b84e-10d502124636"}}}], "length": {"value": 0.0244121, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c44afe7e-8438-4d2c-a1e6-382731061903", "name": "l(r:p1rdm115-p1rlv144)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2d46cd2-9caf-47a7-b134-a29fccd91b9c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b7dbf54-f6bc-4e20-b2f3-8c63a44dd993"}}}], "length": {"value": 0.0176755, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f0aa2a13-e0c6-4712-8ce1-2b96b3454699", "name": "l(r:p1rdm116-p1rlv98)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0d6e82b-cba7-4c7e-8715-d73c3530bad7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "82f19d5c-0941-411d-8baa-3ba029471dae"}}}], "length": {"value": 0.0189352, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b9299fb3-8eb3-4d8c-beab-ef5d8bb3bd1a", "name": "l(r:p1rdm116-p1rlv136)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0d6e82b-cba7-4c7e-8715-d73c3530bad7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b45d086e-8e0d-42f4-a8ec-6d3a9579a96b"}}}], "length": {"value": 0.0258527, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "50eab12d-7e60-4f3e-86f8-77d7b63e1519", "name": "l(r:p1rdm115-p1rdm116)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2d46cd2-9caf-47a7-b134-a29fccd91b9c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0d6e82b-cba7-4c7e-8715-d73c3530bad7"}}}], "length": {"value": 0.012779, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1a90bcc3-121b-46ea-94ea-72690102cce8", "name": "l(r:p1rdm115-p1rdt52lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c70a7331-8c41-4370-b053-3eae432d52ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2d46cd2-9caf-47a7-b134-a29fccd91b9c"}}}], "length": {"value": 0.0312606, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a96a0a61-3593-4283-b799-abda634a973a", "name": "l(r:p1rdm122-p1rlv125)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "329f78a6-af13-4ceb-bc87-4660d497c22e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3367cc2-b096-4cfb-ae71-038eb9e06b46"}}}], "length": {"value": 0.027476800000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6105b98f-5c04-4aaf-8f0c-a630b2e674a6", "name": "l(r:p1rdm122-p1rlv148)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "329f78a6-af13-4ceb-bc87-4660d497c22e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa8af0a4-4d55-41e4-83d1-4fe349920e38"}}}], "length": {"value": 0.0149493, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "34c5ce67-2b3c-449c-a145-88ccef71510b", "name": "l(r:p1rdm121-p1rlv111)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d595142-3854-4152-b64a-6cda8396a523"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66748ae6-b6ef-4228-bb0f-f9a121f0e1a3"}}}], "length": {"value": 0.03370220000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f9ab571c-93e7-490b-be92-60d27d05330f", "name": "l(r:p1rdm123-p1rlv131)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2e27276-ea6c-40a3-92d3-4648ec9d235d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "499fb461-ccb6-436a-8078-eec9beffb4a9"}}}], "length": {"value": 0.0223731, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f08beed6-f030-42b2-b689-6fd6dffe7d03", "name": "l(r:p1rdm121-p1rdm123)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d595142-3854-4152-b64a-6cda8396a523"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2e27276-ea6c-40a3-92d3-4648ec9d235d"}}}], "length": {"value": 0.013548500000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6733f40f-da94-451d-ba9c-afc9bfd279e4", "name": "l(r:p1rdm121-p1rdm122)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "329f78a6-af13-4ceb-bc87-4660d497c22e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d595142-3854-4152-b64a-6cda8396a523"}}}], "length": {"value": 0.0118562, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "50295530-0eb2-46e9-b8d5-a2010ea2855a", "name": "l(r:p1rdm122-p1rdt53lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2536a0eb-a35c-40d4-9773-b78379e7481a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "329f78a6-af13-4ceb-bc87-4660d497c22e"}}}], "length": {"value": 0.0118562, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2688b58c-4fd5-467c-9a5a-8962e7d77466", "name": "l(r:p1rdm124-p1rlv141)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9f62740-f47f-4c97-bae7-4380fe83fcbc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb69a6a9-3eaf-4fc3-82be-0eec77455a82"}}}], "length": {"value": 0.0132542, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f0af7522-e5a1-45b8-a7fa-b575d9c6c63d", "name": "l(r:p1rdm120-p1rlv89)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1071344-55a0-4684-9fbf-5729ec1f21c2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24d75e9a-0249-48ca-ad10-32738bb6a519"}}}], "length": {"value": 0.010837, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c06a98a5-6584-47f6-80ff-d3e030eb948f", "name": "l(r:p1rdm120-p1rdm124)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9f62740-f47f-4c97-bae7-4380fe83fcbc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1071344-55a0-4684-9fbf-5729ec1f21c2"}}}], "length": {"value": 0.0349944, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7714abfb-4610-4b7d-9630-1be09cdc28fb", "name": "l(r:p1rdm124-p1rdt53lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2536a0eb-a35c-40d4-9773-b78379e7481a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9f62740-f47f-4c97-bae7-4380fe83fcbc"}}}], "length": {"value": 0.0174998, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e080f5fa-042f-4074-8eea-968559086793", "name": "l(r:p1rdt54lv-p1rlv90)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57889d14-4aac-4aee-a9e2-677a047e8054"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e06b2ac7-926e-4caf-afac-386910d4ea5e"}}}], "length": {"value": 0.05434540000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2e600f0e-d9b7-4e78-961b-8a6d0b046494", "name": "l(r:p1rdt54lv-p1rlv105)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57889d14-4aac-4aee-a9e2-677a047e8054"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fe82ede-430d-454d-b9d0-e212d0621ea1"}}}], "length": {"value": 0.0270168, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "26085e14-749e-4f2b-a8c0-be910144cf4c", "name": "l(r:p1rdt56lv-p1rlv96)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85ad3bf0-7e82-4e32-8106-faddcf725bdf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31508077-f731-47cb-94a9-869d7910e406"}}}], "length": {"value": 0.0243138, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d926d302-a341-4969-9971-0260425c8bef", "name": "l(r:p1rdm131-p1rlv804)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a60b127d-0530-495e-b3b9-2ebabf070fa1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a11ba246-99d9-4cf5-a557-bec53c75e6fb"}}}], "length": {"value": 0.0159541, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "23ec8047-b4d9-4836-9ad5-57087153b0b5", "name": "l(r:p1rdm131-p1rdt56lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85ad3bf0-7e82-4e32-8106-faddcf725bdf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a60b127d-0530-495e-b3b9-2ebabf070fa1"}}}], "length": {"value": 0.09807820000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3f894fd6-ef69-4853-be69-9ad20f68588d", "name": "l(r:p1rdm133-p1rlv99)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bf5bf18-363d-4f4e-bf10-9ffc601c0f30"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc4a448a-c6cb-4714-b8e6-b75bc6bc219c"}}}], "length": {"value": 0.0124594, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2680f81d-187f-458a-87c9-3e3af28acdaa", "name": "l(r:p1rdm133-p1rdt58lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3367c40-9f47-42d9-b627-bc502b170f2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bf5bf18-363d-4f4e-bf10-9ffc601c0f30"}}}], "length": {"value": 0.0166928, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "79b3a5aa-4572-4e8e-81ec-f62100bf8f85", "name": "l(r:p1rdm134-p1rlv101)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32e76273-c930-4506-9610-8cbfca04af67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48d1be49-5aca-4e18-8b85-2a1274b3f26d"}}}], "length": {"value": 0.027751, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e553c362-e091-4433-818b-930c420bf0a0", "name": "l(r:p1rdm134-p1rdt58lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3367c40-9f47-42d9-b627-bc502b170f2a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32e76273-c930-4506-9610-8cbfca04af67"}}}], "length": {"value": 0.0166928, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "aab15890-22e5-493d-8c40-2a9eb3680b9c", "name": "l(r:p1rdm135-p1rlv100)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7b11b31-78f1-41fa-b511-df76daad0efc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62a0d673-eaba-4032-9038-8095e2d53999"}}}], "length": {"value": 0.0216228, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "045e775e-d108-4d2d-bff1-fd70db392191", "name": "l(r:p1rdm135-p1rdt59lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8aca9934-9439-4ce6-9ee3-475980324054"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a7b11b31-78f1-41fa-b511-df76daad0efc"}}}], "length": {"value": 0.01639, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "299c7e4a-01dd-4183-8922-cd3a145251f0", "name": "l(r:p1rdm136-p1rlv121)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a415176a-ddab-47a0-9ce7-54c53c4c0f11"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0dbaab50-3abc-4207-82dc-5fcc5be68aad"}}}], "length": {"value": 0.024910800000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "def46ab3-205a-44d1-8334-ca8d8e6177c4", "name": "l(r:p1rdm136-p1rdt59lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8aca9934-9439-4ce6-9ee3-475980324054"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a415176a-ddab-47a0-9ce7-54c53c4c0f11"}}}], "length": {"value": 0.018122, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0a52364f-f121-431c-a2b3-2b5afc7a1064", "name": "l(r:p1rdt60lv-p1rlv102)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2517cea-05d3-4b7f-b9fc-0df0fde81235"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06a432e3-dd37-4c52-b954-6652bb529c8e"}}}], "length": {"value": 0.027151, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "45d4171e-dfd6-4632-a1f4-1631c7bb39fb", "name": "l(r:p1rdm138-p1rlv104)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e53344e0-e328-4acd-b159-e1f8cc246996"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c76c5b8f-1994-470c-a024-b97c73b9bb41"}}}], "length": {"value": 0.024191, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fd16c16e-bcb3-49ac-b2c8-5b3f035f1a47", "name": "l(r:p1rdm138-p1rdt61lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70f11a44-826f-45b8-9dc3-0f51ce6c9733"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e53344e0-e328-4acd-b159-e1f8cc246996"}}}], "length": {"value": 0.031133800000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8f90a935-dde4-4055-911b-e8879ea22ef8", "name": "l(r:p1rdm139-p1rlv124)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "022bda10-6b1a-408b-a231-adb63e189d14"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e5ca78b-6151-4a35-8a04-1bab215f0f10"}}}], "length": {"value": 0.0139389, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ff500abb-a8c2-406e-b3f7-762556f3baf4", "name": "l(r:p1rdm139-p1rdt61lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "70f11a44-826f-45b8-9dc3-0f51ce6c9733"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "022bda10-6b1a-408b-a231-adb63e189d14"}}}], "length": {"value": 0.04687960000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "229322ea-6622-4b66-b281-0c2279fd872b", "name": "l(r:p1rdt63lv-p1rlv109)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fac6d4e1-b14d-4973-9626-6a4bde2d2a42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c76fc99c-c160-4ed0-85dd-ec3da962bb24"}}}], "length": {"value": 0.0188407, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "29137b68-38a0-4299-9224-4de2da7e7ec2", "name": "l(r:p1rdt63lv-p1rlv112)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fac6d4e1-b14d-4973-9626-6a4bde2d2a42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25edc94b-a44b-4200-8cde-73941c2818b8"}}}], "length": {"value": 0.04148810000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "90fa423f-c3aa-41a3-b1ff-5e27be2447cf", "name": "l(r:p1rdm143-p1rlv139)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21b14d95-6634-4f0e-a380-d5e57328d825"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8b515111-3455-471a-aba8-92c82624a195"}}}], "length": {"value": 0.0108102, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "34f808d1-99d2-4282-862a-0ada3cd93d88", "name": "l(r:p1rdm143-p1rdt63lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fac6d4e1-b14d-4973-9626-6a4bde2d2a42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21b14d95-6634-4f0e-a380-d5e57328d825"}}}], "length": {"value": 0.016739300000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4283d362-7320-4954-872c-29955cf66239", "name": "l(r:p1rdm145-p1rlv113)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09182ca9-8ea2-4d1c-9c3e-5850a77c1b66"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2756378a-0c67-47cf-969d-bdb9e55c8a4b"}}}], "length": {"value": 0.020074400000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "040ec575-fb08-4511-ad29-6f7f2a4d7af6", "name": "l(r:p1rdm145-p1rlv128)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09182ca9-8ea2-4d1c-9c3e-5850a77c1b66"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56bc8935-c658-424c-83d8-0d13bf8d292a"}}}], "length": {"value": 0.0115543, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c1b08193-75f8-4a5a-bf68-d42b893314b1", "name": "l(r:p1rdm145-p1rdt65lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ae9cb89-7cb8-48c6-a5bc-4178ee364ae8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09182ca9-8ea2-4d1c-9c3e-5850a77c1b66"}}}], "length": {"value": 0.0459314, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0091adf2-477d-4aec-bab4-b4f1d4f1e4bd", "name": "l(r:p1rdm147-p1rlv838)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "de7551d6-5168-440c-8fe2-9f17e0904c29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7ffe87d-4424-4495-83c1-6765d385207c"}}}], "length": {"value": 0.0255431, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8d2187a7-f961-459a-84c8-fd146db95437", "name": "l(r:p1rdm147-p1rdt65lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ae9cb89-7cb8-48c6-a5bc-4178ee364ae8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "de7551d6-5168-440c-8fe2-9f17e0904c29"}}}], "length": {"value": 0.0470531, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2ae9cae5-3620-485e-bc07-7fb5feee034e", "name": "l(r:p1rdt66lv-p1rlv114)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfb9fa3b-c758-4c2e-bc51-f297b1ed21bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7934cd3-dcd6-4b67-8206-8a3636b6f75d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "8024cb11-d099-42e8-a763-d30f1bb4a619", "name": "l(r:p1rdt68lv-p1rlv118)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd2d6296-a302-4027-9e5f-c24a56a1a1ac"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "247e37b3-d6d0-41d7-a6b3-ee29d415da50"}}}], "length": {"value": 0.059931, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "145aef75-cb5e-433d-8d5a-8361f88a52f2", "name": "l(r:p1rdt69lv-p1rlv129)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7057debb-bd4d-4156-a253-0f3a14cdd784"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6c42586-4f46-45c6-910f-90fca771cfd2"}}}], "length": {"value": 0.0182448, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "07a96d7b-4253-4b07-938f-5f40eb0597b4", "name": "l(r:p1rdt69lv-p1rlv140)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7057debb-bd4d-4156-a253-0f3a14cdd784"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47b7d9f8-ca72-4a77-af67-74ee561f7f10"}}}], "length": {"value": 0.0205388, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "326b2815-73fb-47a1-b2b2-e52a6009bae3", "name": "l(r:p1rdt70lv-p1rlv133)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02440066-bc62-4629-96c5-4b497827de5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31dc8280-eb14-4f87-85d7-8eae17013fe7"}}}], "length": {"value": 0.027257900000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0896fb8c-8a94-4a92-8427-e52dd8da6f11", "name": "l(r:p1rdm155-p1rlv134)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43d5d2c5-10f6-4e89-91fa-5186f269b659"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "425bdcfa-9753-4ef5-bb38-9e014ae779dc"}}}], "length": {"value": 0.0117214, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "67b0fa5c-c109-4dc4-a7e5-8a596918e2c5", "name": "l(r:p1rdm155-p1rdt71lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e71f106d-4b41-405f-bce9-3d06b336a554"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43d5d2c5-10f6-4e89-91fa-5186f269b659"}}}], "length": {"value": 0.024182, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "68303935-f043-4a5f-ae67-0cef20dd642e", "name": "l(r:p1rdm156-p1rlv145)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8357e543-eba0-4863-9d95-e34d84a3fae7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1704e67-dfa3-4a6b-a3f4-7ebba9d27537"}}}], "length": {"value": 0.014900100000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bfa069fa-7070-4e5b-b9aa-1521209b1000", "name": "l(r:p1rdm156-p1rdt71lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e71f106d-4b41-405f-bce9-3d06b336a554"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8357e543-eba0-4863-9d95-e34d84a3fae7"}}}], "length": {"value": 0.013317800000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5900d375-7f71-4fe1-a29a-4d36a9287091", "name": "l(r:p1rdt72lv-p1rlv147)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b59eeab-d997-4186-ab59-0424644d5aeb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "070d9a60-c6f2-424c-bd0f-66c52d349f0c"}}}], "length": {"value": 0.021214800000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "35f35705-9799-435b-ae55-94c357a8cb75", "name": "l(r:p1rdm158-p1rlv149)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35f3fd4d-f962-4e4e-89d8-8b41a07ff57d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "063e89ea-6dd0-404f-abfb-21686f3041ed"}}}], "length": {"value": 0.0223159, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "88271973-bd02-47cf-8ce6-9297ca915d33", "name": "l(r:p1rdm158-p1rdt73lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f027d15-df82-4989-93e5-a3b40c862b08"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35f3fd4d-f962-4e4e-89d8-8b41a07ff57d"}}}], "length": {"value": 0.0177535, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "94aed7aa-d694-4d27-ac2a-69f72d010664", "name": "l(r:p1rdm159-p1rlv167)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b8d2667-d52b-46b3-ace4-2ad2b4e3050e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5187e006-621e-4c15-9604-0272ae62887c"}}}], "length": {"value": 0.0172799, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3f4794ef-c7bb-47ed-ae29-ece483a30c44", "name": "l(r:p1rdm159-p1rdt73lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f027d15-df82-4989-93e5-a3b40c862b08"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b8d2667-d52b-46b3-ace4-2ad2b4e3050e"}}}], "length": {"value": 0.0177535, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9a4c7fc8-af6b-46fd-a354-08371ebfcf7e", "name": "l(r:p1rdm160-p1rlv150)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb4a799f-0e03-4ba6-b8ce-8f5e117fd2c2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b9979ec-4e43-4feb-a617-28191e9dd9d8"}}}], "length": {"value": 0.023161300000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d7a1bde2-f7a2-4d8d-8c90-3c65fbc01fba", "name": "l(r:p1rdm160-p1rdt74lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37880102-8a9c-4f7b-930a-b29a94241866"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb4a799f-0e03-4ba6-b8ce-8f5e117fd2c2"}}}], "length": {"value": 0.0168665, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4d2c8db5-28f9-42a7-b24f-191844d2df53", "name": "l(r:p1rdm161-p1rlv169)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "243cdb10-5012-48b5-809f-1952913bf655"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e326756-7ead-4099-a065-9f2de5693197"}}}], "length": {"value": 0.0219801, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "dfdccb19-3918-4a66-8ff9-42e75bc5e315", "name": "l(r:p1rdm161-p1rdt74lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37880102-8a9c-4f7b-930a-b29a94241866"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "243cdb10-5012-48b5-809f-1952913bf655"}}}], "length": {"value": 0.0168563, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "94875e3d-2424-4911-a398-14b27da184b9", "name": "l(r:p1rdt75lv-p1rlv151)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "699bbf24-59ba-4dba-8bd4-1cf04a7e6e47"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "345b5c48-cd35-418e-bc08-50c06f5dff09"}}}], "length": {"value": 0.0195504, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a9a39282-bd02-4e82-ad57-8abf21c4bad6", "name": "l(r:p1rdt76lv-p1rlv154)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ecf2223-f120-45b4-8aab-a36d60161aec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ccdfbc7-d3a6-4f74-ad32-25ff11a2e3b7"}}}], "length": {"value": 0.013038, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "84f9badb-2feb-4fc0-9f7b-2e8a011fde0b", "name": "l(r:p1rdm163-p1rlv153)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0bd295ef-2c38-4c6b-915a-73900e920b92"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ebbe09dd-7560-4eff-9e32-803f14b4ce7c"}}}], "length": {"value": 0.0190604, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9844c82d-1619-481b-9355-a508b593d8f2", "name": "l(r:p1rdm163-p1rdt76lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ecf2223-f120-45b4-8aab-a36d60161aec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0bd295ef-2c38-4c6b-915a-73900e920b92"}}}], "length": {"value": 0.0157338, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "79b6b890-dc64-4ae0-82bd-de9ffbe2e0de", "name": "l(r:p1rdt77lv-p1rlv155)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3fd9bf7-ecdd-4dcb-966a-f426d5f2ee81"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2452d5af-5aba-4d4b-8cd9-27a95fe6b34d"}}}], "length": {"value": 0.023128200000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "98981286-258e-4c7d-9452-c6c98e2b96a6", "name": "l(r:p1rdm166-p1rlv156)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e110db24-1653-41b5-8496-821dfff05769"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f607e6b-9540-4845-9f0c-6c334eb0e807"}}}], "length": {"value": 0.0182012, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8f778f87-7e35-45ec-984f-a71d2d2552a6", "name": "l(r:p1rdm166-p1rdt78lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f0255b7-5369-40eb-8814-959b0d4245b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e110db24-1653-41b5-8496-821dfff05769"}}}], "length": {"value": 0.0187893, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "29265848-23e0-4b5f-bc67-c3a69b4ec89d", "name": "l(r:p1rdm167-p1rlv159)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c108a0c2-3093-4222-9547-5ac08f6d8a4a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0ae6c02-c29e-4bf9-b1d4-ecc7e37e7de2"}}}], "length": {"value": 0.0190142, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "70765cfe-bcf3-4651-aef0-ba765d84ad6a", "name": "l(r:p1rdm167-p1rdt78lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f0255b7-5369-40eb-8814-959b0d4245b6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c108a0c2-3093-4222-9547-5ac08f6d8a4a"}}}], "length": {"value": 0.0238255, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "169b1bc9-8c2a-45ba-8108-75b0f300554e", "name": "l(r:p1rdt79lv-p1rlv164)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "624d03d5-ac53-4d58-ac86-62834fa13c61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61460072-bdc5-4a70-96fa-8ecfa71623f4"}}}], "length": {"value": 0.0140409, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "289216e0-4528-483f-acbb-e2f23d34c2c3", "name": "l(r:p1rdm168-p1rlv157)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "937989ee-4525-4394-b04f-37d77a2c910c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4355a473-4643-4f72-afe8-80ce773ca8e8"}}}], "length": {"value": 0.030818, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9f6477d9-5d1d-40fe-bb83-7e5a13092058", "name": "l(r:p1rdm168-p1rdt79lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "624d03d5-ac53-4d58-ac86-62834fa13c61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "937989ee-4525-4394-b04f-37d77a2c910c"}}}], "length": {"value": 0.012795000000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bb55e3ed-4ff8-4c38-8295-e3849dbb9b29", "name": "l(r:p1rdt80lv-p1rlv158)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ce05c72-facf-447f-ba14-cc2ef64579a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1cd7284-17fb-4382-a29d-dd8c5bfd7541"}}}], "length": {"value": 0.020056, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "09956226-9e3a-4f6d-9b35-faa0073f0f10", "name": "l(r:p1rdt81lv-p1rlv160)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1b610625-09e3-4b72-a8fe-b0c36f5e137c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd2fae5a-e5dd-4ad4-8acc-422de00ae83e"}}}], "length": {"value": 0.0130169, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3eead181-f910-4fda-a540-6d31c233bba1", "name": "l(r:p1rdm172-p1rlv161)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2dad274-0d92-42fa-bf1e-a22af034211f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4842819e-3f17-47da-a8bf-c3402c3c00b7"}}}], "length": {"value": 0.0198598, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9f5ed50e-7216-4609-8db5-2605f3480b51", "name": "l(r:p1rdm172-p1rdt82lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9872669f-fd85-458a-8951-ec12965fb42b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2dad274-0d92-42fa-bf1e-a22af034211f"}}}], "length": {"value": 0.0233983, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0c3c8219-32ba-4305-986d-9d50b230171f", "name": "l(r:p1rdm173-p1rlv830)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44bdfec0-2d44-442d-b562-ac786c61a76a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b7538477-32ab-4db6-872d-83be7ec89fd9"}}}], "length": {"value": 0.016941, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2e07e867-c355-4586-876e-f4e62cece9b3", "name": "l(r:p1rdm173-p1rdt82lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9872669f-fd85-458a-8951-ec12965fb42b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44bdfec0-2d44-442d-b562-ac786c61a76a"}}}], "length": {"value": 0.0146175, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fb158784-8660-4b98-bebd-f836c1d4238d", "name": "l(r:p1rdt83lv-p1rlv163)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8dac1e07-5eb6-4945-a3d9-95b77310358d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "471bad88-4514-4b02-aa1a-1d2aaa15557f"}}}], "length": {"value": 0.021129600000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "92015457-1970-4062-ad0b-862739545707", "name": "l(r:p1rdm175-p1rlv165)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9de64e4-b140-4526-af3c-1f7ceaa687bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e7880c9-0932-4395-abf9-2274e400f280"}}}], "length": {"value": 0.0440542, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6b3be467-1489-413f-8884-dffbbb55fcb7", "name": "l(r:p1rdm175-p1rdt84lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdb8aaf1-0e21-42e0-a72d-666646561235"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9de64e4-b140-4526-af3c-1f7ceaa687bf"}}}], "length": {"value": 0.0128709, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "476a440b-2b65-427e-9160-56b6f9589207", "name": "l(r:p1rdm176-p1rlv166)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a6bf0b9-809d-48fb-b8bd-375df052b6cc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21d333f7-7426-4fa6-8ab2-c6118055ece1"}}}], "length": {"value": 0.0268124, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "77c0c35b-8ab2-45bb-9665-5cfb22ed9809", "name": "l(r:p1rdm176-p1rdt84lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bdb8aaf1-0e21-42e0-a72d-666646561235"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a6bf0b9-809d-48fb-b8bd-375df052b6cc"}}}], "length": {"value": 0.014891, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a0cb5616-3b4a-4ef2-a418-0f34f92e5cde", "name": "l(r:p1rdt85lv-p1rlv168)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40f4034e-c735-419b-80cd-d729d75f4692"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "470fe3ed-5b24-438a-ba6d-cdd9f774e5ad"}}}], "length": {"value": 0.0181757, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "60e2ab6d-9475-4352-8dff-e83ebfd55fd3", "name": "l(r:p1rdt89lv-p1rlv174)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1186295-59ff-48a8-b31d-0f7cd40df1ab"}}}], "length": {"value": 0.059378900000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b34af2ca-a059-4e01-93f4-75562afe5d6a", "name": "l(r:p1rdt89lv-p1rlv175)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905e9287-bdb6-44e0-b0af-f59ab4ad4d8e"}}}], "length": {"value": 0.0220486, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7a00cf1f-e224-44c2-b130-ae181cbc684b", "name": "l(r:p1rdt89lv-p1rlv176)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "931c8cee-89fe-447d-8788-af1e5f9f8775"}}}], "length": {"value": 0.0331252, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "5cbc1082-febb-4953-b261-752d2c159e74", "name": "l(r:p1rdt89lv-p1rlv177)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "090d6084-5cc6-473d-99c0-a6309571d633"}}}], "length": {"value": 0.053761, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b428ecd9-3158-4565-9fd1-6e401d34c594", "name": "l(r:p1rdt89lv-p1rlv178)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9debf70-62f4-4870-ad8b-bffc4bc4ad3f"}}}], "length": {"value": 0.0259912, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "81c89f55-1e6d-495b-a730-bfcacf30aafe", "name": "l(r:p1rdt89lv-p1rlv179)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3f45e410-a6ff-4b59-9a33-a6dcf6ab4a29"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb03260b-d7d7-4779-ab2c-37c9a1e34d66"}}}], "length": {"value": 0.0485967, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0f9cbb19-2251-459a-8fef-5974f0e19e65", "name": "l(r:p1rdt150lv-p1rlv285)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d156fdde-5620-4a6f-b8c1-a3ab986fcc88"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d3a86df-2ac5-4959-b857-562795ce84ba"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "a7fc4ccd-23ad-4d23-9c5d-01f39107d778", "name": "l(r:p1rdt177lv-p1rlv337)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d64d858-a9f7-430f-890e-a456f8913c30"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57b88281-b728-4779-82b1-4cc9eb4b41b1"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "6fe53808-07ef-4c59-8888-4ecf921fbd4a", "name": "l(r:p1rdt178lv-p1rlv338)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3314fa8-a838-4028-abb5-043425fd0785"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6b2aba6-a289-4a50-a131-2064047d1341"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "c2486b9c-458d-4c7d-a30b-2005a6509c49", "name": "l(r:p1rdt180lv-p1rlv340)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3e633bc-311e-4698-a413-9c6cf09c42a8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb4797d6-b46e-4058-8985-d9f4b660f0a7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "bd6ee48d-28b5-4315-aa01-18786c9521fd", "name": "l(r:p1rdt181lv-p1rlv341)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05401825-91f8-41f8-9204-ab5806458594"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "54f0ea2c-3849-4ff0-ad8c-e3f65515d178"}}}], "length": {"value": 0.0184707, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1b31f96a-78eb-4c21-a342-8e9911075c8f", "name": "l(r:p1rdt181lv-p1rlv342)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05401825-91f8-41f8-9204-ab5806458594"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13754fdb-4039-49fb-b584-8437191dfb2b"}}}], "length": {"value": 0.0184707, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6268230d-7e2d-460a-a71c-f4728aeb6115", "name": "l(r:p1rdt182lv-p1rlv343)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db407ddd-fb81-4767-99e1-9aeab12fc770"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0197ef22-9f8f-48a9-84de-663a7ce22773"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b1a02585-8b94-4e80-b57f-1077bfeba63f", "name": "l(r:p1rdt209lv-p1rlv377)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4724ea16-dc31-48f8-98b8-b9a223e9a4bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7e1ea241-5329-4db5-996a-df09a9c25687"}}}], "length": {"value": 0.0107399, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "956ab7d4-2958-436c-a13d-ffd2364dc552", "name": "l(r:p1rdt209lv-p1rlv379)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4724ea16-dc31-48f8-98b8-b9a223e9a4bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50225dcf-40bc-44b5-9dec-072ac5b2334e"}}}], "length": {"value": 0.0107399, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2f7cb6af-5e60-46b7-9658-4724b60445a0", "name": "l(r:p1rdt210lv-p1rlv378)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05f6a3bf-d465-4f16-8205-616d1f4dd465"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3ff63a0-bf3f-43b0-807c-935467b4fe46"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "cf7a4cd4-9ab0-4b90-838b-e3dc4f53c107", "name": "l(r:p1rdt211lv-p1rlv380)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1d5af6ce-9a4c-414a-bbd8-15d82f50cb57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ee07ef9-b7b0-4457-be1c-78e754dbcfc7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "d5ffdfd7-04b1-491f-96ab-1d221c5a2721", "name": "l(r:p1rdt233lv-p1rlv415)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "591461d4-20da-4165-a210-4dbaedd81016"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b54aae8-5a94-4e04-882f-748e1c5f1390"}}}], "length": {"value": 0.0211272, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0505f748-32fd-40ee-adcc-f8ae4f7aa5e0", "name": "l(r:p1rdt233lv-p1rlv416)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "591461d4-20da-4165-a210-4dbaedd81016"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99abc7dc-8e15-420f-9bc9-0e6229d4dab3"}}}], "length": {"value": 0.0170787, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3e94a0ef-755f-4c61-8339-9228a6a9a348", "name": "l(r:p1rdm434-p1rlv412)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "019c88af-413c-4331-84f7-923a1df0a303"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b33ed36-116b-4741-9374-6927bd537427"}}}], "length": {"value": 0.0284617, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c321be1c-7377-4681-bef4-1a0174a2eae3", "name": "l(r:p1rdm434-p1rdt233lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "591461d4-20da-4165-a210-4dbaedd81016"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "019c88af-413c-4331-84f7-923a1df0a303"}}}], "length": {"value": 0.0343908, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6be33d65-8fea-460c-a84a-a0e3f510cfd2", "name": "l(r:p1rdm437-p1rlv419)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3b3eb51-c011-4f2c-8a10-c43c9c86217b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7935b9c-b631-432c-a322-9beea73f1fc4"}}}], "length": {"value": 0.0215859, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "98182c6b-dfb8-473b-8d57-952c06f1388d", "name": "l(r:p1rdm438-p1rlv420)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a713d96-e13f-447e-ab9f-012af3e26afe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4d7ed8-5ddd-4127-87ab-eb3f48a580c2"}}}], "length": {"value": 0.0147074, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "befe0c14-01c2-4b06-a7f9-2a47fc69e8cb", "name": "l(r:p1rdm437-p1rdm438)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3b3eb51-c011-4f2c-8a10-c43c9c86217b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a713d96-e13f-447e-ab9f-012af3e26afe"}}}], "length": {"value": 0.0117282, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "578c6339-ef3b-4716-adb1-a9e5b3ed6b05", "name": "l(r:p1rdm437-p1rdt233lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "591461d4-20da-4165-a210-4dbaedd81016"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3b3eb51-c011-4f2c-8a10-c43c9c86217b"}}}], "length": {"value": 0.0343908, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "42624629-eac1-4745-adf2-53d1be42e2d3", "name": "l(r:p1rdm439-p1rlv413)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "adb2d039-e162-43f7-8498-1374581a75fc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8408ac87-a086-46bc-9d88-cca79e17dd62"}}}], "length": {"value": 0.015615700000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5b4cc8dc-fc2d-4cb2-a6bd-7786ab4a81a2", "name": "l(r:p1rdm439-p1rdt234lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e480f304-b192-4107-91e1-131d481657b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "adb2d039-e162-43f7-8498-1374581a75fc"}}}], "length": {"value": 0.0177624, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e091d378-1707-46e2-9007-81ca0fb1783d", "name": "l(r:p1rdm440-p1rlv417)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84570b2e-efeb-477e-be1c-43b9d2922fda"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49dbdd44-a36a-46b5-aef8-558ef7693315"}}}], "length": {"value": 0.0243364, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "808b2de4-c291-4a98-bf76-253fbf95aa27", "name": "l(r:p1rdm440-p1rdt234lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e480f304-b192-4107-91e1-131d481657b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84570b2e-efeb-477e-be1c-43b9d2922fda"}}}], "length": {"value": 0.0354523, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f7407667-b6d5-4229-a8a0-b06a8bc055e6", "name": "l(r:p1rdt235lv-p1rlv421)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d8a6708a-d098-4e02-aac6-4aba7fdc71a5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12dcb168-1bfe-448b-8d9a-f5cb4c61aafe"}}}], "length": {"value": 0.015099000000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8b295164-05a6-4f11-95bb-179fa6784c17", "name": "l(r:p1rdt236lv-p1rlv422)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7dd709e3-c5ec-4a01-8297-11f4d1261c3a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa7bb51b-8ba8-4a05-872a-7f5ce084fe88"}}}], "length": {"value": 0.0221266, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8526a0f0-81c9-4b1e-b0fd-6ca440c0c355", "name": "l(r:p1rdt236lv-p1rlv423)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7dd709e3-c5ec-4a01-8297-11f4d1261c3a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c1e9680-f7de-497c-953a-54f4db2899e2"}}}], "length": {"value": 0.013832, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "85e410b3-3fd8-4adf-b912-606c69de0cc1", "name": "l(r:p1rdt237lv-p1rlv424)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b72726f3-250c-4d98-86bc-5120137bd0f1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1a91c8c-aabd-4fad-8306-908f186a5744"}}}], "length": {"value": 0.0173984, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "63a6ee4f-9a39-4d73-94c7-2011f40c3e2a", "name": "l(r:p1rdt237lv-p1rlv449)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b72726f3-250c-4d98-86bc-5120137bd0f1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "753035df-8705-48eb-92b3-c4bef603b66b"}}}], "length": {"value": 0.0173984, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7090fbe2-cb8c-4c09-b6fa-da9414b54b2b", "name": "l(r:p1rdt251lv-p1rlv439)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42dff28c-89e7-4b56-bf23-3dcdd3ca216f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f771660-4dad-43df-b38b-7da5f6180a25"}}}], "length": {"value": 0.0641388, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d8826333-a219-4797-a8d9-92cd616ce986", "name": "l(r:p1rdt251lv-p1rlv445)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42dff28c-89e7-4b56-bf23-3dcdd3ca216f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d665758-71e1-4478-b39d-671f78f623e5"}}}], "length": {"value": 0.05250030000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f668b2d1-629e-440a-bc89-69bb83227759", "name": "l(r:p1rdt251lv-p1rlv446)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42dff28c-89e7-4b56-bf23-3dcdd3ca216f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acce3105-f519-491c-921a-df1294795742"}}}], "length": {"value": 0.0829969, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "bba4004f-1129-4d09-95ca-69a606870bc4", "name": "l(r:p1rdt251lv-p1rlv447)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42dff28c-89e7-4b56-bf23-3dcdd3ca216f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "042873fa-10df-4de0-a040-ac429b8bf7d9"}}}], "length": {"value": 0.0834464, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3ec5458c-b354-433b-a8d4-78268d281508", "name": "l(r:p1rdt251lv-p1rlv448)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42dff28c-89e7-4b56-bf23-3dcdd3ca216f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bb83d65-630d-4f1d-8e3d-8937a5a05524"}}}], "length": {"value": 0.0573344, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ad0a49de-fc5d-4d28-b860-b1a01394e3bc", "name": "l(r:p1rdt253lv-p1rlv441)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "704fece3-3b83-4c0b-bcd1-d463b3cdaf6b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a778b00-482c-4b81-8213-f17202a105fa"}}}], "length": {"value": 0.0393745, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e5b3ae7c-65ec-457c-83b8-b09122a326b0", "name": "l(r:p1rdt253lv-p1rlv444)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "704fece3-3b83-4c0b-bcd1-d463b3cdaf6b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30f29674-3083-4da2-95e2-a1f11a7eb7f8"}}}], "length": {"value": 0.0393745, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "66809432-ac15-4760-9231-6d4f6bfb9cf9", "name": "l(r:p1rdt254lv-p1rlv442)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "655d8f44-aa2f-4548-a1ca-83fcce9fa7aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6cd667a9-c0ef-49ce-b6ee-7e474d9ae761"}}}], "length": {"value": 0.0182025, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "51d246f9-90d4-4835-bc50-b80c39ceacd0", "name": "l(r:p1rdt254lv-p1rlv443)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "655d8f44-aa2f-4548-a1ca-83fcce9fa7aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2100c17-c0e6-47e9-87f8-72016b22dd4b"}}}], "length": {"value": 0.0182025, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d0823786-024b-4ce4-a47b-e9ad39c63732", "name": "l(r:p1rdt257lv-p1rlv452)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4c28500-44f7-47c6-b8a8-d1e3468494e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb46f1ae-0cdb-45d1-b389-639cdf345f8e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "f289f501-a893-432d-90a7-87d93c77ec10", "name": "l(r:p1rdt258lv-p1rlv453)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad9ffaef-f21b-43da-9f67-3a8271edb6bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6a8a3c7-5165-48b7-8233-30d3af045442"}}}], "length": {"value": 0.0230491, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5c20bbe4-9be1-430f-95f9-596fa613a6e9", "name": "l(r:p1rdt258lv-p1rlv456)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad9ffaef-f21b-43da-9f67-3a8271edb6bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85f0d94e-c096-4d53-ae05-f0dc59f73d02"}}}], "length": {"value": 0.0595648, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0246e7a2-f298-4214-816f-1f9560d5c268", "name": "l(r:p1rdt258lv-p1rlv460)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad9ffaef-f21b-43da-9f67-3a8271edb6bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76b212f9-2e27-4064-a2c5-079786afb1d1"}}}], "length": {"value": 0.0369882, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "647e9cbe-c03f-424e-a989-fff636f9df75", "name": "l(r:p1rdt259lv-p1rlv454)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6a0feb3-78c1-4d69-8d18-2a8c3abdcf54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3493b0ed-43a2-4602-a7ad-a817331c9d8e"}}}], "length": {"value": 0.007000180000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b2c6818b-63e4-4176-97f7-3725e51b766d", "name": "l(r:p1rdt259lv-p1rlv455)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6a0feb3-78c1-4d69-8d18-2a8c3abdcf54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "552153cc-f5be-42ee-9985-9361c2e7e2a1"}}}], "length": {"value": 0.007000180000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "802e828a-0585-47a2-b9f3-0de5df57c988", "name": "l(r:p1rdt260lv-p1rlv458)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d8d796d8-6750-4ca5-ae07-1b07331ce6ee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec66e302-748d-4300-ba65-719de0a906bb"}}}], "length": {"value": 0.0434176, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "46c807d5-43c5-4672-a3dd-a19e5d31c13a", "name": "l(r:p1rdt260lv-p1rlv461)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d8d796d8-6750-4ca5-ae07-1b07331ce6ee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76dd0f1b-4109-4707-a547-f0ab1b6e148f"}}}], "length": {"value": 0.092428, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "79a59573-c06e-4a75-b3f8-53d31d0db6c5", "name": "l(r:p1rdt261lv-p1rlv459)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fe4ec5b6-61fb-4b66-9e43-19d81af88966"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c112196-bcbc-41bc-99a9-f3657c335c7a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "33cd8402-3871-4cca-bc3e-debcfdedae9b", "name": "l(r:p1rdt262lv-p1rlv462)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30952601-1479-4770-9b77-9fe3465310b7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9176da24-7eb5-4b0b-99dd-886c3f974798"}}}], "length": {"value": 0.00892698, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c4e43b97-aaab-467e-ad1b-42d7037f358b", "name": "l(r:p1rdt262lv-p1rlv464)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30952601-1479-4770-9b77-9fe3465310b7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "895d0235-3ee6-4f06-9978-9d615d721ebd"}}}], "length": {"value": 0.00892698, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a2576b3e-d1e5-4d50-a45e-1bc57c336d52", "name": "l(r:p1rdt263lv-p1rlv463)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c7501f4-0394-4766-a3c5-b17fda7f3817"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff9d9cca-1878-478d-a190-b58c9098f13e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "ccb77c32-f2aa-4914-bb43-9d5e74ae182b", "name": "l(r:p1rdt270lv-p1rlv474)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d33a03d6-fddc-4e47-8018-cd7d290b30b0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e589527-d388-4364-87d2-2f4af1a14509"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "31239fc0-0cf9-4784-9c31-840b76d2fb9d", "name": "l(r:p1rdt275lv-p1rlv480)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6715c6a-6869-412a-8e59-e5c2eb03c56b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb55ec0b-b6f7-48a7-8dae-dda95fc34499"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "8efe139e-f094-4b94-bbd7-6baf1eb8bb49", "name": "l(r:p1rdt276lv-p1rlv481)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b478b4f8-8d5e-47b0-a56a-8b991dc8d944"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d9e77ad-42c6-4413-96e6-debfed3c442a"}}}], "length": {"value": 0.0246686, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3108cca4-7ce2-4e79-91c3-6164c8569336", "name": "l(r:p1rdt277lv-p1rlv482)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24486e15-ff1e-45b3-aa02-703263f04844"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d4b708f-cc15-4ee3-87e0-4d26fec02f1e"}}}], "length": {"value": 0.0705132, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "924709b2-b4ce-4ebf-aef2-ea121372a161", "name": "l(r:p1rdt278lv-p1rlv483)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8af5824-d5d7-4cba-98b7-d72993909f22"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d059a618-6f09-404b-b1a0-0e7aa0c55c45"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "7ed80917-269f-463c-95a8-142aa98b6c52", "name": "l(r:p1rdm508-p1rlv484)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d6856ee-d113-45ec-99e0-8a915a89a56c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fde62b60-c5f6-44d6-b2f2-211c21b02033"}}}], "length": {"value": 0.0863808, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "dc284c67-9c82-4d92-ba75-22c40eb1286b", "name": "l(r:p1rdm508-p1rdt279lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bf679fe-712f-4db6-9df9-debb29b7ee73"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d6856ee-d113-45ec-99e0-8a915a89a56c"}}}], "length": {"value": 0.0129614, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "060491fd-0236-4f17-87f0-4f05976cbc99", "name": "l(r:p1rdm509-p1rlv485)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c3bf9bd-d12a-47d7-b2e2-3f31f3a0419b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d2c379-7e19-46c4-8c6e-533fa9db7764"}}}], "length": {"value": 0.0942097, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "39ff8538-f941-481e-9b42-22bd4064b712", "name": "l(r:p1rdm509-p1rdt279lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4bf679fe-712f-4db6-9df9-debb29b7ee73"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c3bf9bd-d12a-47d7-b2e2-3f31f3a0419b"}}}], "length": {"value": 0.0129614, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9f41c3d1-c279-430b-97c6-bf785447f250", "name": "l(r:p1rdt280lv-p1rlv486)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e4eafd2-0f68-4e2a-a62c-89cb877004d4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a54b2228-9e7d-4e6b-939d-ab2765454522"}}}], "length": {"value": 0.0500266, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "23cca4ef-3f22-42e7-8a89-81df492f80d6", "name": "l(r:p1rdt281lv-p1rlv487)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e01a56d-1bfc-4169-9c3e-1373f9dbeb38"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be2d5799-907e-46fd-a389-120aea352775"}}}], "length": {"value": 0.0588997, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9e629ff1-629c-4692-b1b2-89b36d3232b8", "name": "l(r:p1rdt281lv-p1rlv523)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e01a56d-1bfc-4169-9c3e-1373f9dbeb38"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "97c38794-7c60-4ff8-b09b-7503c9604409"}}}], "length": {"value": 0.0588997, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f9183960-d27e-48f4-ae96-51a4370514fa", "name": "l(r:p1rdt297lv-p1rlv524)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a8430e1-656f-4fe2-a11b-00adf429d75d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bef074be-aac4-4d82-a832-641729756802"}}}], "length": {"value": 0.0214257, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "67082ac6-4033-43de-8e8e-060172e68525", "name": "l(r:p1rdt297lv-p1rlv526)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a8430e1-656f-4fe2-a11b-00adf429d75d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ab8e220-faf9-4108-80f8-22d2fe326c3d"}}}], "length": {"value": 0.0214257, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "84650700-4442-4d15-838e-e27a38df0870", "name": "l(r:p1rdt298lv-p1rlv525)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33e93250-9c11-4650-9469-412129855857"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a42f8b99-82c6-4c90-81ea-6ccb38eacfab"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "7b449da2-8e87-4ccd-9f7a-16c7fec58d1b", "name": "l(r:p1rdt303lv-p1rlv531)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6353ab92-f66f-47d8-97ac-058cf030ff82"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32a1d9d7-31c7-4def-88d4-e4d41bd21572"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "e0344bf6-1f0f-4397-9dfd-b63e20f8de7e", "name": "l(r:p1rdt304lv-p1rlv532)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a22ac71-bf3a-4016-86ce-fb25f471be5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1362feeb-2e2c-4dd1-9f49-239c952c6120"}}}], "length": {"value": 0.00939374, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a06c0184-9460-4a48-a932-28ad6fdc65df", "name": "l(r:p1rdt304lv-p1rlv533)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a22ac71-bf3a-4016-86ce-fb25f471be5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f79bc5f-375f-4ecd-b828-eb7b137d7cab"}}}], "length": {"value": 0.00939374, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8ba5afa0-cb40-49c4-9876-5b535d676651", "name": "l(r:p1rdt305lv-p1rlv534)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90948977-fe1a-43b3-a8a4-86c080ae4906"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0eb7074c-0745-4089-9329-aa3495f9b460"}}}], "length": {"value": 0.0332146, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "59645c30-0818-4298-96b3-c2e407a38c87", "name": "l(r:p1rdt305lv-p1rlv535)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90948977-fe1a-43b3-a8a4-86c080ae4906"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9cc91945-564c-4ace-bb53-77150b107b41"}}}], "length": {"value": 0.0280899, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f0cacb07-6f88-4b14-83a4-b12237b908e0", "name": "l(r:p1rdt305lv-p1rlv536)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90948977-fe1a-43b3-a8a4-86c080ae4906"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2ea78a8-b9c5-4760-b153-51b45565069e"}}}], "length": {"value": 0.0133525, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cce21752-5938-47bf-94e3-7a78fc6ba8c6", "name": "l(r:p1rdt306lv-p1rlv537)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53eba878-66fa-4d30-8af4-1f583abe5f16"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9f2dfc9e-0b72-4465-b46a-d4e2a7a08f64"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "7f8caa28-d1d5-4677-b1a8-caeaa8438cd5", "name": "l(r:p1rdt335lv-p1rlv588)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8e448ea-e66d-4e16-80c0-8e742d7cac55"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75628d41-a82d-4425-8aa2-9f377c771a4c"}}}], "length": {"value": 0.0252117, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a90371fa-16c1-4478-aa97-5e4dcfe53c31", "name": "l(r:p1rdt335lv-p1rlv589)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8e448ea-e66d-4e16-80c0-8e742d7cac55"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a1c60be-f1a1-48d6-b396-4cca6d8c4e62"}}}], "length": {"value": 0.0305453, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d3cd2429-6120-47a3-8205-e4b92179c8d4", "name": "l(r:p1rdt335lv-p1rlv590)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8e448ea-e66d-4e16-80c0-8e742d7cac55"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81ce208e-7244-418a-9867-b55b95ba0716"}}}], "length": {"value": 0.0192501, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8e534474-8d24-44b0-9a73-58eba8f2be88", "name": "l(r:p1rdt374lv-p1rlv657)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35993388-185f-4d1d-9dcb-16eb7556728f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e58890e-e6ce-4dda-91c0-5ccfdb5c420d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "d9844c82-b169-457d-9bc1-326623b23d77", "name": "l(r:p1rdt376lv-p1rlv660)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d354e81e-b007-4bbe-b1db-50d7afacd0e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15751ee2-6783-472f-ad57-ec978234fec4"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b54298a1-451c-4e04-b0a2-2a3ce8e8d748", "name": "l(r:p1rdt383lv-p1rlv672)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8569c197-174f-46ef-96c2-e0c674d7b046"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb25bf05-ce7f-405a-8c17-fd166748f7d3"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "6b21aab7-acec-4cf4-ad90-947d2d65d55b", "name": "l(r:p1rdt384lv-p1rlv673)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c56b4839-f007-4c9b-93a7-9147399f983f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31d3267c-7020-4660-9a0b-49cd9d94a5d0"}}}], "length": {"value": 0.0823342, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "05b78e9e-8d95-4a3a-8417-ca2d7471d413", "name": "l(r:p1rdt385lv-p1rlv674)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "579c3e97-d1dc-4306-91e6-4cbbed29f882"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "449992d6-a91b-40ea-9792-5166a5f2c849"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "13c5de65-ecbe-46fc-b13c-9b0ae93f362d", "name": "l(r:p1rdt414lv-p1rlv716)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29a78735-964b-4381-bea0-01e5b1b79be9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "93069f0f-fce7-47cd-b7b3-77e861f59573"}}}], "length": {"value": 0.0271185, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7aa72c83-7926-479e-9241-1847dffc0378", "name": "l(r:p1rdt414lv-p1rlv726)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29a78735-964b-4381-bea0-01e5b1b79be9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fdcbc55-681f-4fe5-8142-4945b25f6fef"}}}], "length": {"value": 0.0271185, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f433fa72-7ae0-4813-aec1-c749feeef425", "name": "l(r:p1rdt415lv-p1rlv717)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "789d55de-619d-43cd-b056-ebe1be4c2dea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd8fd159-f747-4ee4-a426-787f4eef4b42"}}}], "length": {"value": 0.0174256, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "40648953-ee06-4844-ac24-ebe40af874cb", "name": "l(r:p1rdt415lv-p1rlv724)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "789d55de-619d-43cd-b056-ebe1be4c2dea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3658479-7369-4bd9-be54-e7768c93a808"}}}], "length": {"value": 0.0174256, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "38efc7d5-3134-4ecb-a601-e7bab591df93", "name": "l(r:p1rdt416lv-p1rlv718)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473f5822-3412-4f3d-836e-f62314efa5b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4a1453b-98a3-4c2d-8ac2-c8b2ab1bfa4f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "42acdb9f-2a40-47c7-9aba-003a71207202", "name": "l(r:p1rdt417lv-p1rlv719)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98bb09be-6506-49e8-8fd8-1a01d6861162"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3153167-8b4c-40e4-abb7-3bdef86950c3"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "a06652f1-5337-439b-bde4-2b0916c1d9af", "name": "l(r:p1rdt418lv-p1rlv720)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e189aaf-7650-49b4-83dd-94a29111aca2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cdbc11b7-5abf-4ff8-8d26-53faf4b1f3f5"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "c090ab4d-ac69-4ffb-8288-8e0f550fad74", "name": "l(r:p1rdt419lv-p1rlv721)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d9603d6-5e5e-4cc0-aa86-1bdb80f7e1cf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf12b67c-4df5-4dcb-a2e2-6ae2d0f82e65"}}}], "length": {"value": 0.08840930000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c9d83670-5d7e-4b3e-907b-e3d7877eccf2", "name": "l(r:p1rdt419lv-p1rlv723)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d9603d6-5e5e-4cc0-aa86-1bdb80f7e1cf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7551be44-a4ca-4edb-b823-6495d163201e"}}}], "length": {"value": 0.0583611, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e16c8db8-7dcb-4a01-9073-23a5a1d29c5f", "name": "l(r:p1rdt419lv-p1rlv725)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d9603d6-5e5e-4cc0-aa86-1bdb80f7e1cf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2bcbabc-a7fc-4230-8ec1-b6050af9cf58"}}}], "length": {"value": 0.0308381, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b986d57f-f8a8-4cd7-a6ec-334c76f99e58", "name": "l(r:p1rdt420lv-p1rlv722)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "51673983-9230-421b-8501-bf71601b1b13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4b7c6c65-e18c-4e79-b419-8894deb0d345"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "270edca9-1e67-412f-8e69-5ffb1e583c7d", "name": "l(r:p1rdt438lv-p1rlv749)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41f19802-32ca-4afc-8418-fe93e3ced1bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80983704-a98f-46dc-a09f-700bd7df1a29"}}}], "length": {"value": 0.0289764, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "538e127f-786f-4818-89c8-a58995828ae0", "name": "l(r:p1rdt438lv-p1rlv756)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41f19802-32ca-4afc-8418-fe93e3ced1bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3c3b0fb-5a5d-439e-a350-b97ba0df41a0"}}}], "length": {"value": 0.0289764, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f81dbe0e-d0d1-46b8-be6d-f9a7a1fc6ef9", "name": "l(r:p1rdt445lv-p1rlv764)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bc7e7e51-f849-4bf4-b720-462daeb21932"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e368704b-6c4b-4afb-a577-4b0d7a96dd65"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "2f183098-d22d-473c-bc33-af8fab5902e3", "name": "l(r:p1rdt446lv-p1rlv766)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0727e1f5-f2ca-4e19-9dc3-89e185002e52"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "07381934-8e9b-4447-a330-e8af484331f1"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "a5bb6545-64ef-40da-93ad-c0c9ab4b7840", "name": "l(r:p1rdt452lv-p1rlv786)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44f86829-17fc-4e83-b2a5-705454293161"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "180adab2-e49b-42e9-9aeb-42be0a7686c5"}}}], "length": {"value": 0.0235153, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "225bdb8e-1f49-441f-8070-f7ca28084a18", "name": "l(r:p1rdm812-p1rlv775)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b4fed6c4-6907-4601-9671-6f83d582dc45"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d00977fb-8d2a-44ca-aa9e-034894d6e280"}}}], "length": {"value": 0.033048600000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "46b762a3-e999-4dbf-9c4f-a1df60636b0d", "name": "l(r:p1rdm812-p1rdt452lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "44f86829-17fc-4e83-b2a5-705454293161"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b4fed6c4-6907-4601-9671-6f83d582dc45"}}}], "length": {"value": 0.0176265, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f95d010c-9470-489a-a425-a70c0d0e7256", "name": "l(r:p1rdm814-p1rlv776)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "090024f2-1724-4789-96da-174d1f5e65ec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4c5b1f75-47c0-45c3-9ef3-f97a445b242e"}}}], "length": {"value": 0.0217688, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "551a73e5-acdd-437b-a6cc-6aed76529d23", "name": "l(r:p1rdm814-p1rdt453lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d58e1471-844f-46ef-9d9a-43753b1dee25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "090024f2-1724-4789-96da-174d1f5e65ec"}}}], "length": {"value": 0.0176166, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5a95a755-f19a-4c73-a19d-d006865b8bc0", "name": "l(r:p1rdm815-p1rlv819)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ecd0e9ae-cbf4-4435-8a57-ad23e3e037b4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "def7e507-cb62-42f5-8451-b8a742ef4eb2"}}}], "length": {"value": 0.022596800000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cfc97475-b1af-4388-ad2a-4ce25855b710", "name": "l(r:p1rdm815-p1rdt453lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d58e1471-844f-46ef-9d9a-43753b1dee25"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ecd0e9ae-cbf4-4435-8a57-ad23e3e037b4"}}}], "length": {"value": 0.0167209, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "316d6767-840f-4299-b109-2097e8d276be", "name": "l(r:p1rdm816-p1rlv777)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2e41779-98fa-453d-b4df-10a5dd61a4b5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fb1fca8-7985-4356-a8de-7433fef7a454"}}}], "length": {"value": 0.02155, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f75a9d71-e1a4-402d-bef5-4d848ec31d32", "name": "l(r:p1rdm816-p1rdt454lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b3e7941-9bdd-48f9-a4a5-a553da9bbb57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2e41779-98fa-453d-b4df-10a5dd61a4b5"}}}], "length": {"value": 0.0516187, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d259a7e7-8125-4187-bd47-e94dac2aaab6", "name": "l(r:p1rdm817-p1rlv789)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "87e4ddc3-ccc3-48af-bc35-d7d85f324ee7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9ce2439-fcc7-4965-81ee-f875db83b003"}}}], "length": {"value": 0.0112431, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "61eacf7d-42ae-4dc6-93af-6e874d82465b", "name": "l(r:p1rdm817-p1rdt454lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b3e7941-9bdd-48f9-a4a5-a553da9bbb57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "87e4ddc3-ccc3-48af-bc35-d7d85f324ee7"}}}], "length": {"value": 0.034455, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4b038cb4-9d4c-4388-b73a-07e32d9bdeac", "name": "l(r:p1rdm818-p1rlv800)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf188897-9db5-4ff4-8c5b-5932a8a794cf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3126c61-9602-45cf-8d57-27d26c14ca7e"}}}], "length": {"value": 0.0215285, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ac12c3ae-f77a-49ba-9a39-1cb0876944f4", "name": "l(r:p1rdm818-p1rdt454lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0b3e7941-9bdd-48f9-a4a5-a553da9bbb57"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf188897-9db5-4ff4-8c5b-5932a8a794cf"}}}], "length": {"value": 0.0352686, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6f93c84f-0710-47ab-a637-536624b07499", "name": "l(r:p1rdm819-p1rlv778)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b757a90a-ade8-486f-90f1-e7c5e13708ba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80d58665-ee8a-4f4e-a906-dc15aa3d8c6f"}}}], "length": {"value": 0.0239474, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8371aa9a-7c91-415a-8947-852337c10539", "name": "l(r:p1rdm819-p1rdt455lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53b40b3c-db5a-4fa0-bedb-f293c6eac473"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b757a90a-ade8-486f-90f1-e7c5e13708ba"}}}], "length": {"value": 0.0220829, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "56703918-b9f0-445c-923f-0b94682269a1", "name": "l(r:p1rdm820-p1rlv787)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea28f170-6bf0-47f7-a089-8375dff2ad4a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0089ee3-0cb4-434c-adc4-c91a8441ef0a"}}}], "length": {"value": 0.0195656, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "36bacdd9-ce23-4cee-9360-b33171a5e6e4", "name": "l(r:p1rdm820-p1rlv811)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea28f170-6bf0-47f7-a089-8375dff2ad4a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "052949b1-9e85-4be7-993c-9e97efda3657"}}}], "length": {"value": 0.0433217, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a9571498-62a2-471e-8799-f99e7d47a967", "name": "l(r:p1rdm820-p1rdt455lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53b40b3c-db5a-4fa0-bedb-f293c6eac473"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea28f170-6bf0-47f7-a089-8375dff2ad4a"}}}], "length": {"value": 0.0172275, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "18797b51-4af7-4275-9dee-63bd226546e9", "name": "l(r:p1rdt456lv-p1rlv837)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6abe982-a205-4607-bacf-08e9d7cb6f54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33492e0f-c907-46c6-a529-503480b642bb"}}}], "length": {"value": 0.0139503, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0a607995-b86f-4370-a9b7-e32ca59422de", "name": "l(r:p1rdm822-p1rlv779)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3cae47a-4077-44e6-9761-fc30d85c3442"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fbc761bf-480c-465c-9479-279832c50bc2"}}}], "length": {"value": 0.0269896, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f52fa39d-c9fd-4e85-85bc-c2a8df92edbc", "name": "l(r:p1rdm822-p1rdt456lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6abe982-a205-4607-bacf-08e9d7cb6f54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3cae47a-4077-44e6-9761-fc30d85c3442"}}}], "length": {"value": 0.0541811, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "656582d9-cadf-4851-9af9-1fedf3643435", "name": "l(r:p1rdm823-p1rlv831)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84ca6719-0bbc-440a-b0eb-23b8f32dcf47"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be4b6c4e-78d0-4c8e-907c-619f1e43c149"}}}], "length": {"value": 0.0211142, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c7c588e1-b801-4e20-968d-74dbf8bb0382", "name": "l(r:p1rdm823-p1rdt456lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6abe982-a205-4607-bacf-08e9d7cb6f54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84ca6719-0bbc-440a-b0eb-23b8f32dcf47"}}}], "length": {"value": 0.0102805, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "836ed46a-5f6d-4870-8499-1278a9ec7351", "name": "l(r:p1rdt457lv-p1rlv780)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "866745cc-62c9-429f-8389-fcc5a1710f17"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20dcf67f-f04f-498a-830d-557ba7b4d867"}}}], "length": {"value": 0.0223005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8a6c23db-3a7c-425d-b48b-633fdc42fc2c", "name": "l(r:p1rdm826-p1rlv783)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf7e29df-0880-4c8c-aa5c-c43f24dd820e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d1a96d5-f971-4116-9642-769ef5b97e7c"}}}], "length": {"value": 0.0163209, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7ed37ca1-5449-46b0-8458-47d0591766d5", "name": "l(r:p1rdm826-p1rlv795)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf7e29df-0880-4c8c-aa5c-c43f24dd820e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb137176-0642-4d87-ae40-1b7b0e1cb214"}}}], "length": {"value": 0.0159024, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1d6bc55d-4607-481e-9105-0b616cb72843", "name": "l(r:p1rdm827-p1rlv791)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8fafab6a-7d1c-4b87-94b3-5bc4d09ff95d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fe9bb3f-e3c1-4b59-b39f-f62271a55bdd"}}}], "length": {"value": 0.0242315, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5bb2309e-ef7a-4950-be3f-4ea437e50a10", "name": "l(r:p1rdm826-p1rdm827)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf7e29df-0880-4c8c-aa5c-c43f24dd820e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8fafab6a-7d1c-4b87-94b3-5bc4d09ff95d"}}}], "length": {"value": 0.0328507, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "dad113c6-9e9e-4700-9435-c7ff0a205da7", "name": "l(r:p1rdm826-p1rdt457lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "866745cc-62c9-429f-8389-fcc5a1710f17"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf7e29df-0880-4c8c-aa5c-c43f24dd820e"}}}], "length": {"value": 0.0167732, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d1330071-2d41-4078-9307-b70a676ad0f8", "name": "l(r:p1rdm829-p1rlv801)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc2d45e2-caa5-4f7d-976e-ccb045c30559"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ecc45b2-1fbe-4a31-995f-e2f8fffe61a7"}}}], "length": {"value": 0.0173132, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6d008500-ace5-48f8-b33f-b4d50e08262d", "name": "l(r:p1rdm829-p1rlv817)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc2d45e2-caa5-4f7d-976e-ccb045c30559"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11064c6f-3b7a-43b5-96ca-7ef96be3815e"}}}], "length": {"value": 0.0169258, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bbc1606e-a1f3-4038-adcb-7d343a8b0784", "name": "l(r:p1rdm829-p1rdt457lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "866745cc-62c9-429f-8389-fcc5a1710f17"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc2d45e2-caa5-4f7d-976e-ccb045c30559"}}}], "length": {"value": 0.0335366, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9afa8eb4-0776-4773-bde9-230acba79717", "name": "l(r:p1rdm831-p1rlv781)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c668ab72-249e-4463-a3b4-863c7fe826c1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98c5ba15-a339-478a-a79f-9298fab16a54"}}}], "length": {"value": 0.0157907, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ec1f3dfe-9be2-448d-895d-a61b55020888", "name": "l(r:p1rdm831-p1rdt458lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67e071ab-e3dc-4779-9e81-585547cd22ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c668ab72-249e-4463-a3b4-863c7fe826c1"}}}], "length": {"value": 0.0148102, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "737caffb-1251-4b71-ad12-6e6bd5bcc4ab", "name": "l(r:p1rdm832-p1rlv843)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "92f03cbf-2585-4e0e-ab0a-cda0b267b34d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3bc013f-c78d-4a3c-b27f-826c3025de0e"}}}], "length": {"value": 0.0182301, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "be49c7ea-d626-4897-b7c0-0ea973232fd8", "name": "l(r:p1rdm832-p1rdt458lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67e071ab-e3dc-4779-9e81-585547cd22ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "92f03cbf-2585-4e0e-ab0a-cda0b267b34d"}}}], "length": {"value": 0.0184885, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5925af09-96ab-46bf-abc1-3ec6d4d2624c", "name": "l(r:p1rdt459lv-p1rlv782)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9eb57d99-ae80-43da-b0cb-b26bdd583e1a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "78a4f54a-017a-41b0-85c8-b3e408c21c08"}}}], "length": {"value": 0.0258607, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8d191be9-fb1c-439a-ac8b-e150326846f5", "name": "l(r:p1rdt460lv-p1rlv784)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028bc055-0ee6-4729-8cd2-15bd7153f975"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2823b5b9-bcc3-4b30-9874-89dc33ec80d2"}}}], "length": {"value": 0.0153083, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "01c60984-030f-4370-8898-c1ca4a48a722", "name": "l(r:p1rdt460lv-p1rlv797)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028bc055-0ee6-4729-8cd2-15bd7153f975"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b1c34f1-2613-46aa-9a9f-686ee518e559"}}}], "length": {"value": 0.0114124, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "983e5468-f132-471e-8de4-a2d98111b7bd", "name": "l(r:p1rdm837-p1rlv806)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "790d0b88-fed2-4c90-bfdf-44d3c31d3d8d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d9f269a-e476-4b82-a258-479d812d008d"}}}], "length": {"value": 0.0126883, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2cfbe94b-e247-4450-bba8-f81b935875b7", "name": "l(r:p1rdm835-p1rlv796)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0e1d710-2ab1-43ca-a7c1-8f05a6c0b753"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59662cef-c126-4188-ad86-844f6cabaf34"}}}], "length": {"value": 0.0156616, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4fe3046b-4238-4a56-b548-8a1681e4538b", "name": "l(r:p1rdm835-p1rdm837)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "790d0b88-fed2-4c90-bfdf-44d3c31d3d8d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0e1d710-2ab1-43ca-a7c1-8f05a6c0b753"}}}], "length": {"value": 0.0179452, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2f533d69-4418-47da-be78-5ac5b4c94399", "name": "l(r:p1rdm837-p1rdt460lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028bc055-0ee6-4729-8cd2-15bd7153f975"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "790d0b88-fed2-4c90-bfdf-44d3c31d3d8d"}}}], "length": {"value": 0.0703462, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e073f275-9a06-4a39-b591-4624acf201a2", "name": "l(r:p1rdm838-p1rlv810)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83fdcccd-6a26-4311-aad3-da67dac5af42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fb4a881f-684d-48e4-a6f0-5832f73d140a"}}}], "length": {"value": 0.0133783, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a23cc94c-4329-4e58-908f-3f124f3c4745", "name": "l(r:p1rdm839-p1rlv822)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "344c24ef-9d54-4c1a-9aa4-852a76ddbec7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d7ce197c-cee4-40df-b1d7-be13f1be8bb1"}}}], "length": {"value": 0.026775, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9052c72c-1afa-4aae-ab91-a44fd081b6e6", "name": "l(r:p1rdm840-p1rlv839)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0649432-ddb6-4648-8efe-27ee1fd959e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48e97be9-1f80-457f-a56e-79f54458c620"}}}], "length": {"value": 0.0161282, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7b128ad7-4208-4cdc-8fe3-a452dcc56bf8", "name": "l(r:p1rdm839-p1rdm840)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "344c24ef-9d54-4c1a-9aa4-852a76ddbec7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0649432-ddb6-4648-8efe-27ee1fd959e4"}}}], "length": {"value": 0.0193155, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6751f34e-86f1-4742-bcbf-9599466eaa30", "name": "l(r:p1rdm838-p1rdm839)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83fdcccd-6a26-4311-aad3-da67dac5af42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "344c24ef-9d54-4c1a-9aa4-852a76ddbec7"}}}], "length": {"value": 0.0193228, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a3012458-a638-42aa-9386-6e16993d49e7", "name": "l(r:p1rdm838-p1rdt460lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028bc055-0ee6-4729-8cd2-15bd7153f975"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83fdcccd-6a26-4311-aad3-da67dac5af42"}}}], "length": {"value": 0.0193155, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0ea070ec-3b8d-4c37-8cf9-11c6930961e5", "name": "l(r:p1rdm841-p1rlv785)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "505b390e-ffd3-482a-8ae9-b8d6bd8be94f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa98d6c6-7086-4033-a9af-c0a33e802942"}}}], "length": {"value": 0.0383319, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "64541dee-7746-4e3a-93ea-f335ec5f5254", "name": "l(r:p1rdm841-p1rdt461lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd9a4931-435b-4b48-907c-024c0b8a4816"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "505b390e-ffd3-482a-8ae9-b8d6bd8be94f"}}}], "length": {"value": 0.0196806, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3ee4a741-0ae5-41a1-9e6f-04e31c8cbce7", "name": "l(r:p1rdm842-p1rlv793)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "172dd9d0-eab4-4481-9edd-f868e6ed87d9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0e8c4bc9-0688-43e6-93a8-9664c9b618b7"}}}], "length": {"value": 0.0393311, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e73d98ae-6229-4f85-99ef-3e20d6469868", "name": "l(r:p1rdm842-p1rdt461lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd9a4931-435b-4b48-907c-024c0b8a4816"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "172dd9d0-eab4-4481-9edd-f868e6ed87d9"}}}], "length": {"value": 0.0393612, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "92814b38-b3fd-497d-bd3d-8166ce56fb13", "name": "l(r:p1rdt462lv-p1rlv790)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d96f458-607c-4820-90b1-6fb2625ace7f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf42fa7f-370e-400e-8f6d-76eb8c70ecb9"}}}], "length": {"value": 0.0135001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c513a390-dacc-41d8-84e2-d8c1c494e6af", "name": "l(r:p1rdm843-p1rlv788)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ac64728-e64c-4241-8a3f-b884f11c6393"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c9f470d9-6ead-4413-ad8a-7ccc69ae9237"}}}], "length": {"value": 0.0145732, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "78bb8d17-03cd-4ee9-91a7-b347bd572978", "name": "l(r:p1rdm846-p1rlv864)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2086cded-e13c-4683-824e-9e15f99e12e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e2a8871-7bc4-497f-9954-38db92cb3eba"}}}], "length": {"value": 0.0186895, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "13f88096-53de-4f16-99b0-bb6660af5596", "name": "l(r:p1rdm843-p1rdm846)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ac64728-e64c-4241-8a3f-b884f11c6393"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2086cded-e13c-4683-824e-9e15f99e12e8"}}}], "length": {"value": 0.0176441, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c52a3921-ae5b-4628-bddd-3ff0bd8a700c", "name": "l(r:p1rdm843-p1rdt462lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d96f458-607c-4820-90b1-6fb2625ace7f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ac64728-e64c-4241-8a3f-b884f11c6393"}}}], "length": {"value": 0.0186824, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cc7add68-0788-446c-b784-1994d85a83eb", "name": "l(r:p1rdm845-p1rlv840)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b4620a0-c781-422e-8cc7-3ceed9a0c8dc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "024961c3-25f4-4a15-a52a-7f88dc652766"}}}], "length": {"value": 0.046968, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "65243760-4f2f-4d5d-8d33-e47ffe9a3b4c", "name": "l(r:p1rdm845-p1rlv865)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b4620a0-c781-422e-8cc7-3ceed9a0c8dc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "abdfa5db-c398-4638-805d-6d55597e1921"}}}], "length": {"value": 0.0131897, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b331290f-e764-4cff-b625-e8475759c1a7", "name": "l(r:p1rdm845-p1rlv867)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b4620a0-c781-422e-8cc7-3ceed9a0c8dc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1a7cca48-fd4b-4630-a479-55f2b6ada03b"}}}], "length": {"value": 0.0296877, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "bc9614b3-e07c-4eab-b885-d06bc6380a70", "name": "l(r:p1rdm845-p1rdt462lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d96f458-607c-4820-90b1-6fb2625ace7f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b4620a0-c781-422e-8cc7-3ceed9a0c8dc"}}}], "length": {"value": 0.0137562, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "25952ee5-154e-4e8f-9fa0-73f87e781bd5", "name": "l(r:p1rdt463lv-p1rlv792)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f660c35e-85f8-4f0e-b03b-806006c76c67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f806232e-0a52-46d5-80f7-7ea3a914137a"}}}], "length": {"value": 0.0161855, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b48f1192-2fba-4630-93a6-3be9d6b52672", "name": "l(r:p1rdm850-p1rlv860)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c397a5a5-21bc-4f4d-9f24-7af1219b70e7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bada1117-5605-4aec-9314-8013ed243e3c"}}}], "length": {"value": 0.0408644, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d33c5ecb-5a3f-4998-a939-ade4ab891a57", "name": "l(r:p1rdm850-p1rdt463lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f660c35e-85f8-4f0e-b03b-806006c76c67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c397a5a5-21bc-4f4d-9f24-7af1219b70e7"}}}], "length": {"value": 0.013479, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2e6bf64f-c3c4-4d85-9090-27d3db1d86e7", "name": "l(r:p1rdt464lv-p1rlv794)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "749e07aa-74ce-40f2-a352-9c55f9914377"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eecc456-41af-4242-ab30-d8ca45d55a2c"}}}], "length": {"value": 0.0144527, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c1905497-9abe-4faa-bd82-2075dd0d3940", "name": "l(r:p1rdm852-p1rlv825)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17b42dae-f856-4945-ba7a-9d3f47e049fe"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d209dff6-7a24-41ef-947a-8c6f79c2d65c"}}}], "length": {"value": 0.0239195, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "49992f45-5856-436a-a479-f60b021e18fc", "name": "l(r:p1rdm852-p1rdt464lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "749e07aa-74ce-40f2-a352-9c55f9914377"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17b42dae-f856-4945-ba7a-9d3f47e049fe"}}}], "length": {"value": 0.0188143, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ee5d8865-3fd3-4795-a0b8-dfd4e9a93cac", "name": "l(r:p1rdm853-p1rlv829)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08c93f8a-9600-4ffd-8e18-576d433ce777"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e3a1bd0-69fe-42bb-993d-2094ecc658ce"}}}], "length": {"value": 0.016328, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bccbc133-6fa8-4fa3-a2bc-802cdda86910", "name": "l(r:p1rdm853-p1rdt464lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "749e07aa-74ce-40f2-a352-9c55f9914377"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08c93f8a-9600-4ffd-8e18-576d433ce777"}}}], "length": {"value": 0.0188277, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c3fc0daf-894b-469f-9e4e-90bd63d9f129", "name": "l(r:p1rdm855-p1rlv809)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5ad091a-3b6a-4069-a642-104c28a94dc4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e0f8ee8-795f-4bea-bf7a-e2c477eefb89"}}}], "length": {"value": 0.0141744, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1520e88a-1c47-4c6d-8a0d-2904cb8c3a88", "name": "l(r:p1rdm855-p1rdt465lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "433b0872-49c4-452c-941c-8083a72840ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5ad091a-3b6a-4069-a642-104c28a94dc4"}}}], "length": {"value": 0.0498634, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "d406b735-8fac-47c1-b56e-db92b40af1d0", "name": "l(r:p1rdm856-p1rlv862)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eaf112db-b9dc-4d90-b030-3e26188aaf2b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5e2c3a2-32c0-4bb9-9802-265cec784974"}}}], "length": {"value": 0.0132627, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c94f9ba6-f842-44b4-937f-ca55007e9b89", "name": "l(r:p1rdm854-p1rlv798)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb73d9f2-aefb-430c-babd-ac02422eb212"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c30005d7-7e42-4a08-8935-0c7227fba4a6"}}}], "length": {"value": 0.0514932, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "fe2fe4cc-1ca1-49ea-ace0-0dbe19fab608", "name": "l(r:p1rdm854-p1rdm856)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eaf112db-b9dc-4d90-b030-3e26188aaf2b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb73d9f2-aefb-430c-babd-ac02422eb212"}}}], "length": {"value": 0.0253738, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2708a02c-5630-4ed5-bb7d-7e48b577f60a", "name": "l(r:p1rdm856-p1rdt465lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "433b0872-49c4-452c-941c-8083a72840ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eaf112db-b9dc-4d90-b030-3e26188aaf2b"}}}], "length": {"value": 0.0330337, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2d1d33df-5e6c-431b-a65b-5d1417397b37", "name": "l(r:p1rdm857-p1rlv799)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c274aa99-a566-4915-83af-7115bec586b1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6f706d9d-0cb1-453b-9ca5-377f7d766099"}}}], "length": {"value": 0.022264, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "10265fad-8f7c-43c0-865e-ed7430319af3", "name": "l(r:p1rdm857-p1rdt466lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f422478c-0d77-48c8-87fb-e883d945f8a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c274aa99-a566-4915-83af-7115bec586b1"}}}], "length": {"value": 0.0280491, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "bc234c0a-aedd-48db-91de-21fa0c5454f3", "name": "l(r:p1rdm858-p1rlv815)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "caa7d639-522c-4fd6-8b74-73a337bd67d2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a134556-828b-4e0c-8773-2f207802e33a"}}}], "length": {"value": 0.011569, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9545bc08-0145-463c-b762-538f3e078558", "name": "l(r:p1rdm858-p1rdt466lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f422478c-0d77-48c8-87fb-e883d945f8a6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "caa7d639-522c-4fd6-8b74-73a337bd67d2"}}}], "length": {"value": 0.0785759, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9953a9df-5156-41c7-bec3-13c3ee28db49", "name": "l(r:p1rdt467lv-p1rlv802)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23ed76af-dcb2-4333-ae4c-d7439a37cf87"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2436086-d5c4-4b70-a402-e7d1b6f5b77e"}}}], "length": {"value": 0.023669900000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2548bca4-fda9-4a73-910a-19b98378697f", "name": "l(r:p1rdm861-p1rlv823)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a4bf0e0-92f0-4cd9-afc5-65d9ed242271"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81802469-7320-47e9-b826-fbb33bd371ab"}}}], "length": {"value": 0.0345947, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8f4cba40-f07f-44e4-bac9-1440e21e8bee", "name": "l(r:p1rdm860-p1rlv803)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bfca289-c04c-45d9-8104-40089fc1737e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "018c978c-5673-4090-9792-b75ee161f6d2"}}}], "length": {"value": 0.0184835, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6bde25a7-76c5-4800-9e4b-43f9aeacabc8", "name": "l(r:p1rdm860-p1rdm861)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a4bf0e0-92f0-4cd9-afc5-65d9ed242271"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bfca289-c04c-45d9-8104-40089fc1737e"}}}], "length": {"value": 0.0148709, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fa82ac3a-35f9-4698-aead-a39ffd2d44cf", "name": "l(r:p1rdm861-p1rdt468lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b368fb8f-7f4d-4558-b6b2-2e1db4087727"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3a4bf0e0-92f0-4cd9-afc5-65d9ed242271"}}}], "length": {"value": 0.014361200000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "835c6b61-9f3f-4249-9990-71565e51e175", "name": "l(r:p1rdm862-p1rlv833)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1daf402d-faec-4230-b4ab-1efa6283ac0f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eb57fc4-636d-4923-9f4a-d308b062599f"}}}], "length": {"value": 0.019033400000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1b317b7f-25ad-49f7-aeea-76bf76f69a9a", "name": "l(r:p1rdm862-p1rdt468lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b368fb8f-7f4d-4558-b6b2-2e1db4087727"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1daf402d-faec-4230-b4ab-1efa6283ac0f"}}}], "length": {"value": 0.0659529, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "40e9f9b9-d755-457c-ae45-10112f652013", "name": "l(r:p1rdt469lv-p1rlv805)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d12ab15f-746d-462b-b395-e2b330ba1226"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0475b34e-14ab-48e4-9df7-7444de1cde7d"}}}], "length": {"value": 0.0142913, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7eb1f89d-2f21-4647-98bc-44051405b731", "name": "l(r:p1rdt470lv-p1rlv858)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15ab2647-a801-4cb5-a1f7-528118ff5dea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab33ce2f-3131-4cfb-8df2-329fb4aa76b7"}}}], "length": {"value": 0.0299737, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8ee7e39b-981a-4a50-a8aa-4beac6fb4788", "name": "l(r:p1rdm864-p1rlv807)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d861761c-3fe7-437d-917d-8beb24318a42"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "aa259be8-8a61-461a-9e58-d4aaf1ce82db"}}}], "length": {"value": 0.0310907, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "bcb37d15-54f7-4625-abab-989665dada61", "name": "l(r:p1rdm864-p1rdt470lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15ab2647-a801-4cb5-a1f7-528118ff5dea"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d861761c-3fe7-437d-917d-8beb24318a42"}}}], "length": {"value": 0.0179311, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5baa0f0e-f822-49b5-9ad4-b3251d29ee4a", "name": "l(r:p1rdt471lv-p1rlv826)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40d98c0b-4c66-4581-9553-f5f57c4b27b9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "06746d4d-3db8-45b1-888e-d3d9e405ccaf"}}}], "length": {"value": 0.0163584, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fdac3d14-fa24-42f8-9bae-84816b5ad58b", "name": "l(r:p1rdm866-p1rlv808)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "467753c6-5c1f-4a9d-8a7d-21419b25565f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dcb86a4-e6d7-48b4-b5c2-904635de271b"}}}], "length": {"value": 0.0174196, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0e801fac-7a5f-4816-949a-70e0e49ec4fc", "name": "l(r:p1rdm866-p1rdt471lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40d98c0b-4c66-4581-9553-f5f57c4b27b9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "467753c6-5c1f-4a9d-8a7d-21419b25565f"}}}], "length": {"value": 0.0199112, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "050d509c-ca7e-4b08-84a4-bc625adcd272", "name": "l(r:p1rdt472lv-p1rlv866)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f026a1d3-23b0-4454-a09b-e1c08cc06392"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b4834dc-6bdf-4102-bc13-589392b2e75a"}}}], "length": {"value": 0.0127516, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ed35c9fb-26b6-408a-a136-c0d4237551af", "name": "l(r:p1rdm868-p1rlv812)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0ca3ea5-ad01-4e52-883a-c07805f613dd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26fea867-af5f-4213-b9c3-487975d1285e"}}}], "length": {"value": 0.00862481, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "54aae335-7d0d-4c7e-af07-9024a6d3f6cd", "name": "l(r:p1rdm868-p1rdt472lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f026a1d3-23b0-4454-a09b-e1c08cc06392"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0ca3ea5-ad01-4e52-883a-c07805f613dd"}}}], "length": {"value": 0.0108197, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1a29acaa-ce20-4436-aec1-4fbd44cde777", "name": "l(r:p1rdm870-p1rlv813)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aa0c31f-baa3-4db8-87d9-0a4ab9a83a8a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10d44b60-55c0-4d78-abbb-52c8cd67134b"}}}], "length": {"value": 0.0316898, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e094be1d-90f2-49a3-a4e2-2154277e7184", "name": "l(r:p1rdm870-p1rdt473lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f435ec5-8c03-45ba-925b-83bad9501047"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aa0c31f-baa3-4db8-87d9-0a4ab9a83a8a"}}}], "length": {"value": 0.0167209, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c55075c5-7299-40ca-aa59-5710f1dc5ae2", "name": "l(r:p1rdm871-p1rlv818)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67c560cc-d815-41d4-8087-b66beaacb404"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd8c54fd-14d4-46fa-8bef-59c1097d5026"}}}], "length": {"value": 0.0247114, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a4a2af30-2b5e-4c51-8842-5f18a7462994", "name": "l(r:p1rdm871-p1rdt473lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1f435ec5-8c03-45ba-925b-83bad9501047"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67c560cc-d815-41d4-8087-b66beaacb404"}}}], "length": {"value": 0.016721, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "33025ab1-b5f9-4e7b-8bc9-e05b23ba208d", "name": "l(r:p1rdt474lv-p1rlv814)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "839858f4-3b18-40c3-86f3-e27225e6aba4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b8065f3-8286-4f99-aa56-b9b631a2f838"}}}], "length": {"value": 0.012214300000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4661a900-6153-47f8-ac49-284e1c025724", "name": "l(r:p1rdt474lv-p1rlv827)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "839858f4-3b18-40c3-86f3-e27225e6aba4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c89db91-40fe-4de6-973e-5d8c23e35080"}}}], "length": {"value": 0.0251297, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "97a99a43-b4cf-4a53-8be1-b6f8c9c9d923", "name": "l(r:p1rdm874-p1rlv816)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ec705b7-fdaa-4eca-96eb-5dabb8256c78"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d6de7c2-fd2c-4071-8e90-1513f521cf87"}}}], "length": {"value": 0.00993642, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5d33e469-fbbc-4dbe-8cc0-037dc6f1521d", "name": "l(r:p1rdm874-p1rdt475lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1be3e20a-3890-4e9c-b568-ca99421e751c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0ec705b7-fdaa-4eca-96eb-5dabb8256c78"}}}], "length": {"value": 0.0196806, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3e499df6-5b54-4188-87f6-b114b7ddc9d2", "name": "l(r:p1rdm875-p1rlv834)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c17541ac-d30f-4f0a-9660-f9b9f7012b3a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d437c83c-cbd1-41bf-b455-21123e82d59f"}}}], "length": {"value": 0.0324009, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e4649022-4878-4685-9bfd-6c03c7634b0d", "name": "l(r:p1rdm875-p1rdt475lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1be3e20a-3890-4e9c-b568-ca99421e751c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c17541ac-d30f-4f0a-9660-f9b9f7012b3a"}}}], "length": {"value": 0.0393612, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "aea17153-d289-4fb6-bf02-3c99f43ad7b3", "name": "l(r:p1rdt476lv-p1rlv836)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ffde8c6-9dba-4f13-bda5-a0edf17c736d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12556ab7-c50a-4624-9d84-b85585822245"}}}], "length": {"value": 0.0139229, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d23cc706-758d-4c5f-bfe0-c5d897e7a67d", "name": "l(r:p1rdm878-p1rlv842)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f83e2ade-1911-4124-9fbe-6f482d68eba9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8f304a4-6e39-4288-9b9b-e41bb37c6019"}}}], "length": {"value": 0.015212700000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "34d2a6b1-8462-4bde-bf65-082e9aa25dd8", "name": "l(r:p1rdm878-p1rdt476lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ffde8c6-9dba-4f13-bda5-a0edf17c736d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f83e2ade-1911-4124-9fbe-6f482d68eba9"}}}], "length": {"value": 0.0183516, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1906dc6c-7625-4d68-9c53-d3ec88d367b4", "name": "l(r:p1rdm879-p1rlv868)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "260b560c-e6d6-4069-b67f-067c468a7768"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "009758e3-b4ae-427a-9c30-f2a8bb2953d1"}}}], "length": {"value": 0.0303242, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4573dcbc-735f-4cc2-bedf-3e3bf2bb2e6d", "name": "l(r:p1rdm876-p1rlv820)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5331a4f-ab91-4fea-a301-11b7afb6c8ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "41e1e576-4cc9-4fea-9d87-d436f000a675"}}}], "length": {"value": 0.0226825, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "dad50477-3454-429d-889f-7802e2fe03db", "name": "l(r:p1rdm876-p1rdm879)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "260b560c-e6d6-4069-b67f-067c468a7768"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5331a4f-ab91-4fea-a301-11b7afb6c8ca"}}}], "length": {"value": 0.018351400000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2b2c06e9-faf7-4a27-b89e-2fd4aff2d4f9", "name": "l(r:p1rdm879-p1rdt476lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2ffde8c6-9dba-4f13-bda5-a0edf17c736d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "260b560c-e6d6-4069-b67f-067c468a7768"}}}], "length": {"value": 0.018351400000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f1cee872-ffd6-4181-91ca-28bc5644d2e5", "name": "l(r:p1rdt477lv-p1rlv821)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7c94703b-303a-4713-95c0-b2933fe0e70b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5578d8b4-7c1e-444f-8d27-8c9bf733f420"}}}], "length": {"value": 0.012208200000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "dae4ec0f-7656-4005-b37e-4f869ca62aaa", "name": "l(r:p1rdt477lv-p1rlv828)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7c94703b-303a-4713-95c0-b2933fe0e70b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08c3f5ef-c2d5-4ce2-8fc7-b665d8cbbab6"}}}], "length": {"value": 0.0188029, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e31a013a-6276-486a-95ad-8156f93c04e3", "name": "l(r:p1rdt478lv-p1rlv824)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c93c776d-68b8-4e4e-8e5e-d5e34003473c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "20ce76b6-9305-4525-b77e-b7300edc2c81"}}}], "length": {"value": 0.0283636, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "66a1a477-9441-4daa-8e19-9ae195db32ba", "name": "l(r:p1rdt479lv-p1rlv832)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8037b713-d948-43c9-8370-fb8fcf6dec15"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10373c0d-6a3c-4160-a174-22de447d4c38"}}}], "length": {"value": 0.012648, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1bba640c-d184-4cd8-8d9f-8d718e5d85d0", "name": "l(r:p1rdt480lv-p1rlv835)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "423402f9-4160-481b-9951-a955f8314075"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3bc35476-5839-4095-bea5-36e32450b890"}}}], "length": {"value": 0.0370417, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "12477693-3b27-4bb8-9818-8febe1402966", "name": "l(r:p1rdt481lv-p1rlv841)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1761b021-00e0-4880-9f05-62cf67aef0e6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4eb6c1b4-f09a-44a5-a13f-64051183736d"}}}], "length": {"value": 0.0229879, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4b8f9b84-3375-44e3-996f-8f2b9b7fc95b", "name": "l(r:p1rdt482lv-p1rlv844)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c445ea76-5167-4d55-b0c5-cc53dadc5b5e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26294827-db76-40b6-b652-1e41efdf15dc"}}}], "length": {"value": 0.0225992, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a38cf1c8-e554-4ff7-9189-f9f0861fb6f3", "name": "l(r:p1rdm887-p1rlv846)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3929a951-8b8b-42e9-a839-40c29e680108"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "145d3757-ca09-45ca-9199-465b6b43fbb7"}}}], "length": {"value": 0.025727, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "72d6b0dd-0037-4a7f-b678-dd0aa4abb16a", "name": "l(r:p1rdm887-p1rdt482lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c445ea76-5167-4d55-b0c5-cc53dadc5b5e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3929a951-8b8b-42e9-a839-40c29e680108"}}}], "length": {"value": 0.0374944, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b6f8b4d2-1bc0-4679-9713-9bcd313232ad", "name": "l(r:p1rdm888-p1rlv848)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0318cdac-5c7b-4711-a0d7-9c7e104c8281"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e484d77-29ac-4903-afa3-f677283db883"}}}], "length": {"value": 0.0169569, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "50bbf606-cb43-4516-91a8-dadf8c13416a", "name": "l(r:p1rdm888-p1rdt482lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c445ea76-5167-4d55-b0c5-cc53dadc5b5e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0318cdac-5c7b-4711-a0d7-9c7e104c8281"}}}], "length": {"value": 0.0374944, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "de9da477-e2e9-4af6-be08-69a14dcb5a12", "name": "l(r:p1rdt483lv-p1rlv845)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "475b6a50-9814-4016-bb88-be5b1b2ac31d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b053d449-b15b-4292-9a73-9b7d104a8e38"}}}], "length": {"value": 0.016859600000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6e28be69-05a4-42ac-ad11-d34b22f52d5d", "name": "l(r:p1rdt483lv-p1rlv851)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "475b6a50-9814-4016-bb88-be5b1b2ac31d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48b5535c-f00d-4b48-a23a-87f3f212302f"}}}], "length": {"value": 0.0190238, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "bd6f5a20-0cfc-458e-83ac-da3256bcb423", "name": "l(r:p1rdt483lv-p1rlv859)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "475b6a50-9814-4016-bb88-be5b1b2ac31d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ea0f4f5-2024-45a8-9f8f-f5963e7d2727"}}}], "length": {"value": 0.0273815, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "16ca1d8c-f178-4b98-9b82-1048582e46dc", "name": "l(r:p1rdm892-p1rlv855)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "18ea7daf-9665-4d68-b255-12d41bdb2396"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10611e08-75e2-4422-ac0f-cfb98c7eae4b"}}}], "length": {"value": 0.0184228, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8982efe3-fe34-4f46-8ba6-0da7942cd0e9", "name": "l(r:p1rdm890-p1rlv849)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0398ef91-eeb8-4d34-b05e-e88adabdd487"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a95877ca-8600-4e95-82ac-c51cb82acf16"}}}], "length": {"value": 0.0307799, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "336123d1-06d4-42bc-91ca-b2faf7f420c1", "name": "l(r:p1rdm890-p1rdm892)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "18ea7daf-9665-4d68-b255-12d41bdb2396"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0398ef91-eeb8-4d34-b05e-e88adabdd487"}}}], "length": {"value": 0.0712019, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e18fc9dc-b6c4-48fb-a18a-e11d951be718", "name": "l(r:p1rdm892-p1rdt483lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "475b6a50-9814-4016-bb88-be5b1b2ac31d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "18ea7daf-9665-4d68-b255-12d41bdb2396"}}}], "length": {"value": 0.016043, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0fe81417-b25b-4f18-8740-612e6afbda1c", "name": "l(r:p1rdt484lv-p1rlv847)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f396745a-5edb-4ab8-8bc7-2b181719cbf4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "283142ff-4884-4adc-9d4c-f8615505415a"}}}], "length": {"value": 0.0214364, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cd25035f-8cc9-4351-99d1-da90e1465103", "name": "l(r:p1rdm895-p1rlv856)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e96e4c25-4664-45ae-b77c-9e0047f65c8b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25f84b28-695b-4d32-b96c-914226444b9f"}}}], "length": {"value": 0.0167306, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e2643c5e-63e6-45b4-9a5c-87df5a4bba08", "name": "l(r:p1rdm895-p1rdt484lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f396745a-5edb-4ab8-8bc7-2b181719cbf4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e96e4c25-4664-45ae-b77c-9e0047f65c8b"}}}], "length": {"value": 0.0181803, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e4e3f62f-6a52-4772-8105-017c43ea8625", "name": "l(r:p1rdm896-p1rlv850)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60637f4b-8538-4b21-988c-1b13adecc647"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d49057-9c70-4489-95bb-36b5b574e13d"}}}], "length": {"value": 0.0266685, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c65cddfc-7654-418e-bc98-41fa27f8c007", "name": "l(r:p1rdm896-p1rdt485lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da38ec0a-f37d-4a5c-8da0-93410a8fb475"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60637f4b-8538-4b21-988c-1b13adecc647"}}}], "length": {"value": 0.016779100000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d1a11481-6f65-4363-9e68-bb0fda7a5dc9", "name": "l(r:p1rdm897-p1rlv853)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3464daa0-06b2-4d5d-9901-bb34050fe619"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "365eff25-8ccb-448b-894f-ad662fe6d684"}}}], "length": {"value": 0.0210885, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a013e7d5-c8e8-4c90-8afd-836bd7c9313b", "name": "l(r:p1rdm897-p1rdt485lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da38ec0a-f37d-4a5c-8da0-93410a8fb475"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3464daa0-06b2-4d5d-9901-bb34050fe619"}}}], "length": {"value": 0.014660500000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "1fd6bbe3-8659-48dd-aa1f-9e5788d134f1", "name": "l(r:p1rdm898-p1rlv852)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d9b6dee-73e1-43ab-ac9b-7d20fb77b6df"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32142941-c546-4356-ba80-123b9128b5de"}}}], "length": {"value": 0.0198361, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "c93ddd5b-ec87-4033-ba5f-d8293329e37f", "name": "l(r:p1rdm898-p1rdt486lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5401d366-a5a2-4753-82b7-ce4fa08a1227"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d9b6dee-73e1-43ab-ac9b-7d20fb77b6df"}}}], "length": {"value": 0.03692270000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0dc1cf49-c5f7-475d-958e-e7dfd2b9e65e", "name": "l(r:p1rdm899-p1rlv857)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e5e11ab-e042-4038-85c4-162521871722"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a28cc17a-125d-4b7b-a697-230e3f8853b5"}}}], "length": {"value": 0.0237034, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "00e35878-599e-4958-ab4e-26fccef53f5a", "name": "l(r:p1rdm899-p1rdt486lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5401d366-a5a2-4753-82b7-ce4fa08a1227"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e5e11ab-e042-4038-85c4-162521871722"}}}], "length": {"value": 0.0374944, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b544e958-00d0-45f4-9f80-ee015a8495ec", "name": "l(r:p1rdt487lv-p1rlv854)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47fbd02f-6c12-4bd6-9d6d-2e0cddbfcd88"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2461b6f0-9a40-4b6f-9669-be479da039f3"}}}], "length": {"value": 0.0160302, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7413aa3e-5264-431e-b1ee-96bcb81dc33c", "name": "l(r:p1rdt488lv-p1rlv863)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e517b810-e6b9-4c89-b47d-1921fcf88edc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09a7be46-a1bf-459d-836b-beb64324809b"}}}], "length": {"value": 0.022533, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ac6a59e2-26a8-4380-a237-b8c62ae89797", "name": "l(r:p1rdm901-p1rlv861)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d7f4223-382b-4b9a-9157-baede39de271"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a07d30f-6909-4d74-be8a-1ff8343b4419"}}}], "length": {"value": 0.0239784, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f1b8fe58-3e64-4bad-a83d-6dfa926eb48b", "name": "l(r:p1rdm901-p1rdt488lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e517b810-e6b9-4c89-b47d-1921fcf88edc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d7f4223-382b-4b9a-9157-baede39de271"}}}], "length": {"value": 0.0134887, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b57aaa4c-0468-4c5f-97d9-03a76be33d9d", "name": "l(r:p1rdt489lv-p1rlv869)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25637062-8ca3-4694-a27b-7be93e89fe1f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1fb4003d-498a-494d-89ca-f222d921f63a"}}}], "length": {"value": 0.0208895, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "10466c86-9f76-45e1-94a1-237649c34b3b", "name": "l(r:p1rdm7860-p1rlv7783)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "601a7504-69fc-4c21-a1d8-1a59751d439c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fd7a84bb-8aa4-4668-9791-a363741823e9"}}}], "length": {"value": 0.0587046, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b9060d54-e5ed-415c-9385-ff4782908000", "name": "l(r:p1rdm7860-p1rdt3776lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ae14df0-ab3b-47ba-9f83-c09f03999c76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "601a7504-69fc-4c21-a1d8-1a59751d439c"}}}], "length": {"value": 0.0312996, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "fe5691e5-0fea-4743-911a-02ac9e6cc1a0", "name": "l(r:p1rdm7861-p1rlv7784)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "391504f7-3b2f-47f0-aadd-47de5c89b16b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24e665a0-3ba6-46a7-bc02-327b6f77c409"}}}], "length": {"value": 0.0188851, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "60a19095-6b29-4d9b-89a0-147f382ffe6f", "name": "l(r:p1rdm7861-p1rdt3776lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ae14df0-ab3b-47ba-9f83-c09f03999c76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "391504f7-3b2f-47f0-aadd-47de5c89b16b"}}}], "length": {"value": 0.016714700000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b3634258-f4ed-44fb-98e6-aab051e298ed", "name": "l(r:p1rdt3777lv-p1rlv7786)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4662f3f5-e75b-4b75-a6d6-7ada745d5cca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9af62e3c-9357-4505-a2f6-3b4252dab81b"}}}], "length": {"value": 0.0847582, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2ded4c2a-d082-4ebc-b7cf-7173851ecbf9", "name": "l(r:p1rdm7862-p1rlv7785)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90158ee6-01aa-48ce-867f-8e459e7a5e09"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1571d1a3-a151-4972-8cb1-aeb36b660abc"}}}], "length": {"value": 0.0135756, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cb94f9fd-5645-4d22-80c7-8bbcc0dd1f34", "name": "l(r:p1rdm7862-p1rdt3777lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4662f3f5-e75b-4b75-a6d6-7ada745d5cca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90158ee6-01aa-48ce-867f-8e459e7a5e09"}}}], "length": {"value": 0.0255604, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "17a69667-cf10-4bca-be13-6a7e0e89b592", "name": "l(r:p1rdt5098lv-p1rlv10453)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e734d7a2-9161-41c0-ba78-9f9f87120acd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "09926231-b077-4aa6-afd8-acf89744865a"}}}], "length": {"value": 0.011414400000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "37668bd4-db9e-4657-a30f-6537455366f8", "name": "l(r:p1rdt5098lv-p1rlv10468)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e734d7a2-9161-41c0-ba78-9f9f87120acd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a639e8d-ac8c-46e8-a4b5-6c551612b209"}}}], "length": {"value": 0.010426000000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6f4de8f6-9f4d-4326-879d-2b1d1bd70a9b", "name": "l(r:p1rdt5098lv-p1rlv10482)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e734d7a2-9161-41c0-ba78-9f9f87120acd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d40fc87f-1b73-4ed4-a397-dbc94312dcad"}}}], "length": {"value": 0.0457378, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "eb768007-e1fd-4128-843e-a920a8d99c4a", "name": "l(r:p1rdt5098lv-p1rlv10517)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e734d7a2-9161-41c0-ba78-9f9f87120acd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "efd01236-6ba3-424e-829b-3f3950ce6265"}}}], "length": {"value": 0.0527233, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "81dde824-4245-4f8c-a4cf-9db89dc3aeb4", "name": "l(r:p1rdt5548lv-p1rlv11503)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91754be7-2a91-4a0e-9856-43d08ecc7c70"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "773a6b9e-d708-4f7c-a901-9406bcc3dcde"}}}], "length": {"value": 0.0787524, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "e169b7fb-6b4d-42f9-8e7c-3647a7d1c8a2", "name": "l(r:p1rdt5548lv-p1rlv19645)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91754be7-2a91-4a0e-9856-43d08ecc7c70"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f7efbb32-55d4-409b-a37f-bf01d0620d40"}}}], "length": {"value": 0.0664224, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "4eeb407c-9ccf-4bbd-b2fb-d4024fbdc2db", "name": "l(r:p1rdm11706-p1rlv19640)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4c77c78-e261-4d17-93ff-caad4d86246b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9e90f763-682e-4771-976c-9cd736b72133"}}}], "length": {"value": 0.0418249, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "a13c699c-045f-49d2-b42c-2cdbede20fb5", "name": "l(r:p1rdm11706-p1rdt5548lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91754be7-2a91-4a0e-9856-43d08ecc7c70"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c4c77c78-e261-4d17-93ff-caad4d86246b"}}}], "length": {"value": 0.00976661, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "cc6ab775-6ec1-4a88-8795-fda42a10631d", "name": "l(r:p1rdm11719-p1rlv11513)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15ae4af0-db43-4f1b-bd8c-c6be31d034aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84b9d44e-2c8d-4cee-a9d2-327a41ab8dad"}}}], "length": {"value": 0.0190194, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "7790dc5f-cdac-4888-aef5-99f91b95d8f0", "name": "l(r:p1rdm11719-p1rdt5557lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05b867e6-2f18-49e7-9869-55bd5048c201"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "15ae4af0-db43-4f1b-bd8c-c6be31d034aa"}}}], "length": {"value": 0.0164873, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "ebcc125c-7f65-4704-b548-f54176c23576", "name": "l(r:p1rdm11720-p1rlv19574)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "effa94d0-34ae-4cbe-b8da-fd1693d47b3a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf457d88-958c-446a-9584-73be8c609bbe"}}}], "length": {"value": 0.0842106, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "d84a4af5-3ffc-4402-94bf-55e2b8fce113", "name": "l(r:p1rdm11720-p1rdt5557lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05b867e6-2f18-49e7-9869-55bd5048c201"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "effa94d0-34ae-4cbe-b8da-fd1693d47b3a"}}}], "length": {"value": 0.0174341, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "9f3e9279-5951-47ea-9614-bfdb64faa25b", "name": "l(r:p1rdt5560lv-p1rlv11516)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d5838960-8556-4e4a-95e9-8ba9ffc85141"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86d82a1e-1596-4fb3-9f3d-44c9553396d2"}}}], "length": {"value": 0.034696700000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a10879ee-8cd7-4421-8ad1-8ec8d159db76", "name": "l(r:p1rdt5561lv-p1rlv11517)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "133a0221-0cd5-46d2-af84-e80e7951c96d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "179d1d84-0dfe-4920-a039-009f33bc1d8d"}}}], "length": {"value": 0.0852615, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "3c9c08f9-58e9-4367-aee8-72788caa6a7c"}}}}, {"uuid": "85c749d5-75af-4616-a6ac-4d19148a2db2", "name": "l(r:p1rdt5564lv-p1rlv11521)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8deb73b9-51fc-447d-9da7-14a6dccff646"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8f0f8a2-f528-45bd-8fbd-22f6699fe7e0"}}}], "length": {"value": 0.0157073, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cea46a51-3c46-4491-91ff-28ee6a01fae5", "name": "l(r:p1rdt5566lv-p1rlv11523)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95a5450a-6630-41b8-863f-0c1f3fcfa7ab"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69eba934-3f80-4abc-b5e8-9cdc79aa05a3"}}}], "length": {"value": 0.0858684, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "86229bfc-1da4-4a19-9237-57b2905f74e0", "name": "l(r:p1rdt5568lv-p1rlv11526)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "613d178b-a566-408d-bad0-e4a170eea971"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b97ebb0-09a4-4c42-a10e-e3aff344aa44"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "945a8612-0351-49e2-9f34-8f08e68f05d1", "name": "l(r:p1rdm11742-p1rlv11533)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0460a67f-dcc1-4829-99f8-7a0b6a8cedbc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21b18539-fba6-4b52-b8bf-38c2a6c4abfb"}}}], "length": {"value": 0.05768530000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "93ae1764-d66b-4a19-906e-591b3a1e591f", "name": "l(r:p1rdm11742-p1rlv19643)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0460a67f-dcc1-4829-99f8-7a0b6a8cedbc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f0e181a-fa89-4c5d-a1cb-6080f91331da"}}}], "length": {"value": 0.0190181, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "3dbe6d40-2137-4381-80f7-1f5a50ac28df", "name": "l(r:p1rdm11742-p1rdt5574lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "248e065d-80ed-4926-9625-295c83da6b61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0460a67f-dcc1-4829-99f8-7a0b6a8cedbc"}}}], "length": {"value": 0.00976661, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "793d8149-e4ef-4652-883e-e9f4c27a7e76", "name": "l(r:p1rdm11743-p1rlv19610)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6554d73d-5cf7-4531-a524-78e70b36fd8d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "813f887e-6807-4ffc-90bf-bd30cde9a9df"}}}], "length": {"value": 0.0248503, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "5cc69a86-7b23-4389-bb35-5abe701b58fd", "name": "l(r:p1rdm11743-p1rdt5574lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "248e065d-80ed-4926-9625-295c83da6b61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6554d73d-5cf7-4531-a524-78e70b36fd8d"}}}], "length": {"value": 0.00976769, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "a326f1c4-da78-4141-9db0-66d576e8b34a", "name": "l(r:p1rdt5577lv-p1rlv11540)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21ef4ae6-b80e-49f1-8d00-1cb6e27bc8f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1148946c-8c37-4482-afce-5082cd2b7ad4"}}}], "length": {"value": 0.0511394, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "90d5237c-f3be-49b6-a22e-00bcd5b84d2f"}}}}, {"uuid": "12bccd3a-fe76-4b06-b5e9-4ecf0bc45c74", "name": "l(r:p1rdt5577lv-p1rlv11540)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1148946c-8c37-4482-afce-5082cd2b7ad4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f79b14c8-e77d-49c1-9336-e7407ad4c94d"}}}], "length": {"value": 0.00462191, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "f0e70843-a66a-4f1c-9ec8-537f478ceb4c", "name": "l(r:p1rdt5577lv-p1rlv19608)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "21ef4ae6-b80e-49f1-8d00-1cb6e27bc8f9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "752bcf04-7a44-42b0-9a46-44c243b78eb5"}}}], "length": {"value": 0.0743006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "c97b51a2-4bc9-4f5f-a792-c2cbdf396398"}}}}, {"uuid": "8827a427-b95c-48ee-bab2-53830e656715", "name": "l(r:p1rdt5577lv-p1rlv19608)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "752bcf04-7a44-42b0-9a46-44c243b78eb5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f917b142-d59f-4a51-8c3b-913feb53411d"}}}], "length": {"value": 0.0771446, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9b7200ad-1df7-439b-b20d-bb9280f9771d", "name": "l(r:p1rdm13355-p1rlv13033)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5559c15-cdac-4a4d-a2a0-b99c9befb310"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1564c5f9-8b80-41b4-af09-2a55dee0718b"}}}], "length": {"value": 0.014252, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e1bf48e6-13e2-4a91-89cf-5d84620d1588", "name": "l(r:p1rdm13355-p1rdt6261lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9859b30-0238-493e-be1a-cb6717413ba9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a5559c15-cdac-4a4d-a2a0-b99c9befb310"}}}], "length": {"value": 0.0141814, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "aa2af72e-9572-4467-97d9-6b9af030b224", "name": "l(r:p1rdm13356-p1rlv13036)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba5e6363-0b23-4726-8013-f3d040511005"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23aae8f1-8b9f-4453-9643-b49ffdc80889"}}}], "length": {"value": 0.0296258, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2ca1fa28-2d13-4dfb-b49d-74e91cec5353", "name": "l(r:p1rdm13356-p1rdt6261lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9859b30-0238-493e-be1a-cb6717413ba9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba5e6363-0b23-4726-8013-f3d040511005"}}}], "length": {"value": 0.0175481, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "17ea358b-1515-4a7e-b9cc-da4cd723e829", "name": "l(r:p1rdt6262lv-p1rlv13034)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2172b57-622b-44c1-8388-f1e2b1def312"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3b7bff1-90da-4ee2-8a0f-8e291a7e8ac8"}}}], "length": {"value": 0.012931, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cd2a9d82-271b-4297-97f5-86ec2233a7f8", "name": "l(r:p1rdt6262lv-p1rlv13040)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c2172b57-622b-44c1-8388-f1e2b1def312"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6839f65-9d3b-4bd6-89a4-0c8feb33e98a"}}}], "length": {"value": 0.012931, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cbc3d861-03cf-41fd-9899-1877d9629f93", "name": "l(r:p1rdt6263lv-p1rlv13035)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4717b000-fd39-4647-9fbd-5152323dacee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c6d309ef-b082-4022-a265-4891cdcd6db9"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "5f45d635-24d4-4b92-b676-91cb371f21c7", "name": "l(r:p1rdt6264lv-p1rlv13037)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e916c16-525d-4092-b627-ad44b4bf4ee8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f5d04aa-74fb-4d1a-ac91-6c01a56a94b5"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "f0aff012-ca25-4a95-afab-ae5b5acd6b86", "name": "l(r:p1rdt6265lv-p1rlv13038)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6bb5544-e583-4ded-9a10-23be70f5598e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9a8b4502-31fd-4dce-8717-9860880075b4"}}}], "length": {"value": 0.0390031, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "407a9766-0e87-492a-a15d-f38706b3f5d7", "name": "l(r:p1rdt6265lv-p1rlv13039)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6bb5544-e583-4ded-9a10-23be70f5598e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "34d43081-e4a3-4f1b-8b90-5965458452d0"}}}], "length": {"value": 0.0390031, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "1ecf47fb-4c9d-4c2f-9b13-48fc566a1ff4", "name": "l(r:p1rdt6266lv-p1rlv13041)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8af5f9d5-965c-4a0c-a811-67d3bed744ee"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60144ce1-d4d6-4725-b543-f881894356a5"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "97e95d76-b07f-4991-830b-e51976983721", "name": "l(r:p1rdt6267lv-p1rlv13042)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0ddd898-3193-4bff-80f4-fd4a7eae9aec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "296cd07e-c2e3-4031-abad-9c870a65105d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "3867ca21-d32f-4f5c-940d-37211d717384", "name": "l(r:p1rdt6488lv-p1rlv13513)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1155c2c-544c-45f4-969f-b3ec4f6773bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3243ca2f-a97e-4fbc-981d-85eded2e5e6b"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "d02d53af-3a36-4ac6-9b80-9d033180548f", "name": "l(r:p1rdt6578lv-p1rlv13823)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "555453a3-3fb7-426a-bbd2-9e588d4bd01d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0ca6e47-afec-4d61-885a-e38176b32444"}}}], "length": {"value": 0.047603, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "846f4229-8275-4972-b164-2502491188e2", "name": "l(r:p1rdm14192-p1rlv13789)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2fe65b3-6fcc-4416-bca4-9a0f6551b801"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47a7519a-b550-41e6-99e3-c2115db425fe"}}}], "length": {"value": 0.049152900000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6f4fa352-b028-47aa-9d50-18a0bb0a9afe", "name": "l(r:p1rdm14192-p1rlv13796)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2fe65b3-6fcc-4416-bca4-9a0f6551b801"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "94ac9254-cdbf-4864-b22b-bcfb0a827700"}}}], "length": {"value": 0.0270402, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0b124dff-b54f-45fa-a5d5-8c433190d495", "name": "l(r:p1rdm14192-p1rdt6578lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "555453a3-3fb7-426a-bbd2-9e588d4bd01d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b2fe65b3-6fcc-4416-bca4-9a0f6551b801"}}}], "length": {"value": 0.014767000000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e71fa7ac-b9d3-4a12-b0d7-044c378b6c67", "name": "l(r:p1rdm14194-p1rlv13814)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e0be7c1-65b8-4de4-89f2-56b6bf1ea321"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "028d5ead-7c34-400b-bcc1-c4d706c965d3"}}}], "length": {"value": 0.0199421, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "09b39023-2ff0-4d96-a0ed-ac8b59606a15", "name": "l(r:p1rdm14194-p1rdt6578lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "555453a3-3fb7-426a-bbd2-9e588d4bd01d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e0be7c1-65b8-4de4-89f2-56b6bf1ea321"}}}], "length": {"value": 0.0147579, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "57580946-6dbd-4b0c-98d1-8cad145603ef", "name": "l(r:p1rdt6580lv-p1rlv13791)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5de250a8-ecca-4ab4-9f09-685aaf92d13d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "251f270f-4238-4fe6-8ab3-f884fca7a42d"}}}], "length": {"value": 0.021088, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "aa0e6dd2-2c0f-4177-a823-a0468aa4d055", "name": "l(r:p1rdt6580lv-p1rlv13810)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5de250a8-ecca-4ab4-9f09-685aaf92d13d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab29ca66-d59b-4aa6-b5f6-165add0bc331"}}}], "length": {"value": 0.0102831, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7a87292e-c6a6-4051-9120-26457ad60aa0", "name": "l(r:p1rdt6580lv-p1rlv13815)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5de250a8-ecca-4ab4-9f09-685aaf92d13d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99957459-46a6-4b2b-9813-69b11ca7dad1"}}}], "length": {"value": 0.0257571, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cd0d76c4-750e-4a91-bf36-2fc25a0839cf", "name": "l(r:p1rdt6580lv-p1rlv13819)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5de250a8-ecca-4ab4-9f09-685aaf92d13d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36c12a74-a2ca-439a-a69f-308dd5cb1207"}}}], "length": {"value": 0.0290939, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "506334ac-668e-40db-b38e-3b096457209b", "name": "l(r:p1rdt6584lv-p1rlv13817)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d944119-3782-49dd-8b24-1f68d8ee687c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e96bcc5b-07c5-4289-aec4-0224395c5e8a"}}}], "length": {"value": 0.0927796, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f4e84bae-8f8c-4be0-8536-cd28853d2d45", "name": "l(r:p1rdm14215-p1rlv13801)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "39af24f1-0fa2-465e-a288-2b620d9e9d59"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "accec892-a236-462d-b714-1178393ec992"}}}], "length": {"value": 0.0671973, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0a048391-5c17-4012-930f-0b72f82b3505", "name": "l(r:p1rdm14215-p1rdt6584lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d944119-3782-49dd-8b24-1f68d8ee687c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "39af24f1-0fa2-465e-a288-2b620d9e9d59"}}}], "length": {"value": 0.0384386, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "15c6bf63-883d-4801-a272-90fa9b89b00d", "name": "l(r:p1rdm14218-p1rlv13822)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32db643a-7c82-4816-8629-7935cab09567"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6ade9991-a857-4619-8094-c18f824aaeb9"}}}], "length": {"value": 0.06771510000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6f9c9704-6507-461c-8562-66721f90efd2", "name": "l(r:p1rdm14216-p1rlv13807)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e81f150f-30cd-4c9a-b5b7-7a633633702d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c26fba44-3b81-47de-81e6-522f2daf0534"}}}], "length": {"value": 0.0529333, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "87f002f2-9fae-464e-bb80-cb01a6a0b754", "name": "l(r:p1rdm14216-p1rdm14218)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32db643a-7c82-4816-8629-7935cab09567"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e81f150f-30cd-4c9a-b5b7-7a633633702d"}}}], "length": {"value": 0.0151179, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b1fec959-7ba6-4215-b96e-6ba2d1d19620", "name": "l(r:p1rdm14218-p1rdt6584lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4d944119-3782-49dd-8b24-1f68d8ee687c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "32db643a-7c82-4816-8629-7935cab09567"}}}], "length": {"value": 0.0151258, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7c60e0a9-3fcc-4eba-95b4-8df243a36579", "name": "l(r:p1rdt6587lv-p1rlv13808)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c587698-7940-4edb-9105-f31f1304f7e9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1c795ac7-3b49-4158-996d-2fb1f0337847"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "00db7f54-776f-48ee-8e74-66239598eba8", "name": "l(r:p1rdt6588lv-p1rlv13809)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61045f72-ca3d-4e0d-ac3d-db5fbf099b38"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "687996da-ab03-4544-b0d9-b79b8ac88e95"}}}], "length": {"value": 0.0528036, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "7dd2b848-aa22-4412-b1d1-8022419948bd", "name": "l(r:p1rdt6590lv-p1rlv13820)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a289017a-8ab9-4412-857a-694b3aa2c63d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a2caa70b-9143-4676-834b-bfc7cb41330c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "cce20032-6f5e-4e62-a614-f8c3e1c1e558", "name": "l(r:p1rdt6591lv-p1rlv13821)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8a7c2e99-857f-4119-be4a-daaca586f056"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "66e6c732-919a-4851-9f76-5580ea71669d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "e2cf222a-6a6e-4c2b-88b3-ae9dc77d477b", "name": "l(r:p1rdt7286lv-p1rlv15585)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ad975da-cce7-49cb-be78-20c4abf8975e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17bf6d8f-8215-4294-b921-cc3e34476f1e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "0b6321c0-e593-4fd0-83ef-ccdacf1bca96", "name": "l(r:p1rdt7289lv-p1rlv15590)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56d21681-3c57-4575-af17-f2bbf9874a10"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef2a4478-4644-4bd3-9548-ab1d0be338b5"}}}], "length": {"value": 0.0486531, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a57e0543-e448-4364-97ea-0ec58bfe1197", "name": "l(r:p1rdt7289lv-p1rlv15591)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "56d21681-3c57-4575-af17-f2bbf9874a10"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c04c9ad1-4277-47de-9cec-9ce86e17b4f1"}}}], "length": {"value": 0.0486531, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f9dc052c-0cf6-496a-bdae-32b7e4c0991c", "name": "l(r:p1rdt7293lv-p1rlv15595)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9b0c16f-f433-4aa1-8d00-dc1573dfb5e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "629e2259-2a59-4b20-b8bf-7b3b2c4a48f9"}}}], "length": {"value": 0.0100375, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b490b873-d978-4e8e-b731-5d1a1177b231", "name": "l(r:p1rdt7293lv-p1rlv15598)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9b0c16f-f433-4aa1-8d00-dc1573dfb5e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "af6b7d1b-896f-44ac-8038-748c74507253"}}}], "length": {"value": 0.0100375, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "aaeb1a63-1faf-4245-8aac-9d7ee893de31", "name": "l(r:p1rdm16003-p1rlv15599)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c1ea087-8a4d-49ca-af35-b86aed849c98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ae1bbf1-459f-4346-b525-393b7d1dc958"}}}], "length": {"value": 0.05559190000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6a2caec6-4161-4515-ba83-a4255da193f2", "name": "l(r:p1rdm16003-p1rdt7294lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67d2b31-f05a-4160-83ae-55154224a9ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c1ea087-8a4d-49ca-af35-b86aed849c98"}}}], "length": {"value": 0.0102952, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "fd8a75f0-e4cc-4f0d-9f5a-a88b8512defb", "name": "l(r:p1rdm16004-p1rlv15618)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84040096-aca8-4cee-8539-83ae8f875e98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "200aa7d8-0a43-4086-b0e7-f63cae75671d"}}}], "length": {"value": 0.0495647, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2f1ec0c6-1240-41df-9dbd-567f072a135c", "name": "l(r:p1rdm16004-p1rdt7294lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e67d2b31-f05a-4160-83ae-55154224a9ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84040096-aca8-4cee-8539-83ae8f875e98"}}}], "length": {"value": 0.0103008, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "228ab804-b7eb-4baa-8890-32957676b9b3", "name": "l(r:p1rdm16011-p1rlv15604)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "381018f1-11cd-4519-ad24-d3419116ea84"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "95b45d46-b7e7-46e2-98d9-5034e2fa0a17"}}}], "length": {"value": 0.0544244, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8c2aa039-c379-41ae-a2bc-c5676e9b8d5c", "name": "l(r:p1rdm16011-p1rdt7299lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4cee417a-3410-4907-8621-f0d3fcbc047c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "381018f1-11cd-4519-ad24-d3419116ea84"}}}], "length": {"value": 0.011971, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e8772813-cf45-4c0c-bfb1-0fa439dccaa4", "name": "l(r:p1rdm16012-p1rlv15616)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60d0a9cf-54f3-4049-9957-29839b7beb08"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "43ed408e-35e2-4bca-9060-a0c211aea1e7"}}}], "length": {"value": 0.05365020000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e0c373ed-e460-4f34-a8d1-eb847e2f7d41", "name": "l(r:p1rdm16012-p1rdt7299lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4cee417a-3410-4907-8621-f0d3fcbc047c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60d0a9cf-54f3-4049-9957-29839b7beb08"}}}], "length": {"value": 0.011961, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "7fc7557d-3188-421b-9deb-23156c311c75", "name": "l(r:p1rdt7300lv-p1rlv15605)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "135a6a49-6562-4c6e-a41f-f5f78c0ac3e6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcbee2ff-bf73-4834-bc3c-46fa0cfcad7c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "fb196b4b-b9e0-4682-9687-fc7b48814c94", "name": "l(r:p1rdt7303lv-p1rlv15608)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7cbc8145-b198-46f1-a3fd-55a05637e618"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13d6bce6-9066-43a1-b2b6-00a2a4398958"}}}], "length": {"value": 0.09331, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e5a601cd-32a4-4b1b-9279-6c052d0a0c67", "name": "l(r:p1rdt7308lv-p1rlv15619)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5094655-6494-44a9-b0ff-c5b418dcc11e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905a4857-5d3d-4e51-9ab0-70d634170f92"}}}], "length": {"value": 0.0449182, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "69eca3e0-a956-498c-b4de-f0459f13be05", "name": "l(r:p1rdt7308lv-p1rlv15641)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5094655-6494-44a9-b0ff-c5b418dcc11e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4363602a-eb9c-41b8-8130-7bb839f4eb5a"}}}], "length": {"value": 0.0129519, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8b756ba9-f09a-4289-8963-ac6c4c3bb912", "name": "l(r:p1rdm16029-p1rlv15623)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2fba947f-089b-47f3-8720-e8f3e35c097c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "13f790a1-18c0-498f-8525-fbaf0350947b"}}}], "length": {"value": 0.0220545, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "88313a2a-a20c-49c2-b01d-be23bb684a18", "name": "l(r:p1rdm16029-p1rdt7308lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5094655-6494-44a9-b0ff-c5b418dcc11e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2fba947f-089b-47f3-8720-e8f3e35c097c"}}}], "length": {"value": 0.0183549, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "878d6ef7-4b7f-4b3d-9231-3c35685646c9", "name": "l(r:p1rdm16030-p1rlv15625)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "154999cc-f6d5-458a-8504-e4692344d372"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb08eda2-b277-4bfd-9ea0-9c36765400bd"}}}], "length": {"value": 0.011861000000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "af04168d-2e01-467c-a933-57eb91eefb0e", "name": "l(r:p1rdm16030-p1rdt7308lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5094655-6494-44a9-b0ff-c5b418dcc11e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "154999cc-f6d5-458a-8504-e4692344d372"}}}], "length": {"value": 0.0183492, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "44d47663-a161-4cf0-81dd-d72b5e0b2ec5", "name": "l(r:p1rdt7316lv-p1rlv15632)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a289e26d-2d86-4fdf-942b-881b91ca18eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ccbef4c-6bf7-4892-a3b9-b51aca495137"}}}], "length": {"value": 0.0523363, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "3d9c792d-1901-46b8-8dbc-84c2d3351fa6", "name": "l(r:p1rdt7317lv-p1rlv15633)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16c465cf-c4ae-4702-ba6c-0b7704eda764"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ce7b60c8-43ee-441d-9f18-5b2722dcc0a7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "a62267fd-b877-4828-8016-462ee6d0d601", "name": "l(r:p1rdt7321lv-p1rlv15640)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c855f7bb-1f33-4c3e-9deb-e3f9c5aba07d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "83c2de51-1b04-483c-8ce7-14b9e5e027b9"}}}], "length": {"value": 0.0474361, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c3f2a59a-557e-4560-948b-6a25ec8bf2ef", "name": "l(r:p1rdt7737lv-p1rlv16450)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35be767a-53a1-4fe1-b320-9542dd859d97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5f1e7aa-d93a-4164-8bc0-f920259304a8"}}}], "length": {"value": 0.0142506, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "91de1667-194c-462b-b28f-55a17f4f7220", "name": "l(r:p1rdt7737lv-p1rlv16463)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35be767a-53a1-4fe1-b320-9542dd859d97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d9c505d7-3fb9-4eb5-89c6-c9c8da32fd05"}}}], "length": {"value": 0.0227335, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3a01d0fe-40b1-4fb5-91ca-df152fa306f6", "name": "l(r:p1rdt7737lv-p1rlv16507)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35be767a-53a1-4fe1-b320-9542dd859d97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27afe70a-9123-4b0c-9f50-b5355aafcf7a"}}}], "length": {"value": 0.020775, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5c538261-665c-4f36-ba3f-f5e3a08578c7", "name": "l(r:p1rdt7737lv-p1rlv16584)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35be767a-53a1-4fe1-b320-9542dd859d97"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "344c6b21-94c9-4912-a19e-69fbae5eed27"}}}], "length": {"value": 0.0280855, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4edf7cf8-7538-4d21-8e74-b279ea148c65", "name": "l(r:p1rdt7753lv-p1rlv16475)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c7482f0c-eb85-4e30-a09a-eb9f15bbc22b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d400b1b2-8404-4b80-b110-6f96e000314f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "2037b2b1-5524-4eb7-b64a-da1ecb5f7e62", "name": "l(r:p1rdt7757lv-p1rlv16483)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d343e634-0936-4f21-9e2c-079e19f0dfa1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa6db7ee-126d-4aa9-9733-35ff1c1d5992"}}}], "length": {"value": 0.00228078, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "8d48b987-eaf2-497c-a339-efe11a87bf39", "name": "l(r:p1rdt7757lv-p1rlv16530)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d343e634-0936-4f21-9e2c-079e19f0dfa1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0333a34b-4027-4d9a-9d4a-f867c8a317bc"}}}], "length": {"value": 0.0186713, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8b0bb813-8062-412e-b539-04750931dc13", "name": "l(r:p1rdt7757lv-p1rlv16541)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d343e634-0936-4f21-9e2c-079e19f0dfa1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2f7be042-6681-4694-872d-a1cb701016c7"}}}], "length": {"value": 0.0208942, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "3d9c040a-bb54-4e9d-81b5-25d6fcbcfc1b", "name": "l(r:p1rdt7791lv-p1rlv16573)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "28e5f84f-2fac-4b5c-a669-b16988e4d6ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90d9dbe9-f9c9-4a4e-8ada-cb459778687b"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "af1ad058-7c6a-401b-9fc3-fbfea264ffdf", "name": "l(r:p1rdt7795lv-p1rlv16604)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3959f944-18f5-4daa-a454-3c6bfb7158ff"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f9ecb3f-8b64-4598-a9d1-d794c6800d33"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "504184a8-1f73-4d48-afa4-2910dbbfa798", "name": "l(r:p1rdt8105lv-p1rlv17239)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b2ec0ba-a854-4631-b97a-4674123d6fe6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba567aae-a893-41d3-8fd1-8357d3cab35d"}}}], "length": {"value": 0.00558108, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "b78127ef-db34-49e5-8d34-8d267770eee9", "name": "l(r:p1rdt8105lv-p1rlv17280)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b2ec0ba-a854-4631-b97a-4674123d6fe6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac80cbea-e10a-491a-ba36-06e9fcf74217"}}}], "length": {"value": 0.00558108, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "2375fd38-e5df-4013-92a0-781fb802e32a", "name": "l(r:p1rdm17827-p1rlv17246)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3a01639-0851-466b-abc6-adf52342e772"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "acfdbe95-2d82-463a-9d1f-6fd2688adf16"}}}], "length": {"value": 0.0396397, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b7c185de-5d32-4bcd-8427-c286259946ea", "name": "l(r:p1rdm17827-p1rdt8111lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b639e55-2e33-4582-bb96-06a9d33a3419"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d3a01639-0851-466b-abc6-adf52342e772"}}}], "length": {"value": 0.0160058, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "28b5f84b-cd7d-4034-bdb3-e59c4f80545a", "name": "l(r:p1rdm17828-p1rlv17303)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f70da59-a879-487b-802e-6b7158e425ca"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04eb7e32-e372-4cb0-94a7-ee418f400bda"}}}], "length": {"value": 0.051430000000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "99397bd6-6958-407d-83b1-af4d43cac71b", "name": "l(r:p1rdm17828-p1rdt8111lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b639e55-2e33-4582-bb96-06a9d33a3419"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f70da59-a879-487b-802e-6b7158e425ca"}}}], "length": {"value": 0.0135199, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "0854729a-afef-4d01-8859-67d7f6de1981", "name": "l(r:p1rdt8138lv-p1rlv17291)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dca9b40e-ed8a-4f75-a703-91539f6c3075"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04388b89-16fc-40b3-a060-5bc52032874e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "db220af5-3816-480b-9981-eb1fe35cc177", "name": "l(r:p1rdt8146lv-p1rlv17311)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2bee3961-990e-47ac-b49b-d305f8fe0af8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84ebd9bb-dc50-483d-a3c6-044682d4020c"}}}], "length": {"value": 0.0332245, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0b45d3d6-5c46-46c7-9a97-1f1cf5e43e38", "name": "l(r:p1rdt8167lv-p1rlv17345)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ead5953-70f2-4db2-ba4d-d203c91d85c1"}}}], "length": {"value": 0.0506084, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a4e9e272-25a0-4302-8307-7262bf9ce2f9", "name": "l(r:p1rdt8167lv-p1rlv17357)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf6f74e5-7aa3-4333-bd37-3ce486d54a01"}}}], "length": {"value": 0.0618331, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f0a6e60c-8c24-4e7b-b4ef-7d7ae2b515e9", "name": "l(r:p1rdt8167lv-p1rlv17397)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d38cdffb-41be-48aa-8a03-c6525dd01037"}}}], "length": {"value": 0.0760567, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e1f63203-b54e-40d0-92ec-ae5ba164567c", "name": "l(r:p1rdt8167lv-p1rlv17400)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63177299-2842-4e0d-bf17-7bd2b0afe9a2"}}}], "length": {"value": 0.07573210000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "79e8a7fd-cb8f-4c8b-a89e-4c11077e7b55", "name": "l(r:p1rdt8167lv-p1rlv17405)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b50de14e-9a09-4f61-8998-0979f33b0d0a"}}}], "length": {"value": 0.0505674, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ca4872cb-e641-4360-9f84-ce34923edf34", "name": "l(r:p1rdt8167lv-p1rlv17415)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b038711b-e832-41ab-a406-ac3f8b1507fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86b2527b-73c3-41c4-8ac2-7cb0e8bc2a7a"}}}], "length": {"value": 0.061751, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "93491f53-d77b-43a1-a403-c39b07514ecb", "name": "l(r:p1rdt8169lv-p1rlv17347)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6349165a-d47a-4cf4-84f9-df5c5f3a0e98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d98640c6-d8aa-44e4-9ecf-5998152d3f7d"}}}], "length": {"value": 0.0224066, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4ebf0f0a-64e1-4007-b6e9-f21155e3226d", "name": "l(r:p1rdt8169lv-p1rlv17351)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6349165a-d47a-4cf4-84f9-df5c5f3a0e98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2695decb-d268-46b2-8604-9c33dc90518b"}}}], "length": {"value": 0.0609432, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ca6b10dd-667c-47af-be39-98f12b391661", "name": "l(r:p1rdt8169lv-p1rlv17403)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6349165a-d47a-4cf4-84f9-df5c5f3a0e98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9d61897a-cdac-4b4a-8812-8a8692a3d958"}}}], "length": {"value": 0.038578400000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "31224941-a62e-42aa-ae90-bd7ccc3abecf", "name": "l(r:p1rdt8174lv-p1rlv17353)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4903e82a-8cfb-406e-b4bf-5e01068419a3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f34e3e4e-bebd-4148-bcc7-cbfbecd73a2f"}}}], "length": {"value": 0.0319504, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "55dc7678-dc68-40c6-ba37-585b326681a7", "name": "l(r:p1rdt8174lv-p1rlv17378)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4903e82a-8cfb-406e-b4bf-5e01068419a3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08709e25-b030-4801-ae00-c4879556d8b1"}}}], "length": {"value": 0.0249412, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d5084996-4e4c-4102-b7a5-52e1080ebde5", "name": "l(r:p1rdt8174lv-p1rlv17383)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4903e82a-8cfb-406e-b4bf-5e01068419a3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e1ad135-904d-47ed-ae74-32b38e1c2f88"}}}], "length": {"value": 0.012372, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ced660f6-d339-46dd-ac3a-27e815f3fec5", "name": "l(r:p1rdt8180lv-p1rlv17361)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8e03b63-853e-4cfe-bf4a-3779b2026637"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c705333f-6f1a-4a76-a02e-eaa859e99b70"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "7ef593a9-0e64-4af1-a4bb-e9b4dc9a4c54", "name": "l(r:p1rdt8195lv-p1rlv17385)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "782d6008-7fec-46b6-9461-9e33b79539d3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e835b413-3307-49ef-ad69-cf18a5ae7cfb"}}}], "length": {"value": 0.014752, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4fa1bae6-7d69-404d-b5a5-f546bb5f877c", "name": "l(r:p1rdt8195lv-p1rlv17387)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "782d6008-7fec-46b6-9461-9e33b79539d3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "55382019-a1a5-40fd-b90a-072af40c2258"}}}], "length": {"value": 0.0249337, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "50184f43-49b4-43eb-ae76-8a7342e55633", "name": "l(r:p1rdt8195lv-p1rlv17391)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "782d6008-7fec-46b6-9461-9e33b79539d3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "169a22de-bb0a-4056-8910-151125c4ff9e"}}}], "length": {"value": 0.04456, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "22e31715-a179-406a-9b84-5870965a7242", "name": "l(r:p1rdt8195lv-p1rlv17407)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "782d6008-7fec-46b6-9461-9e33b79539d3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65de341c-589f-4bf9-a708-26fcc94a6c0a"}}}], "length": {"value": 0.0236267, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "121927ec-fbec-42ba-a8a6-4c6dcc5d1eda", "name": "l(r:p1rdt8195lv-p1rlv17417)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "782d6008-7fec-46b6-9461-9e33b79539d3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "67003f0f-6690-469e-82c0-63949ee5241e"}}}], "length": {"value": 0.03781860000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "43975839-0903-4efe-99af-43ae782a4892", "name": "l(r:p1rdt8201lv-p1rlv17394)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76e33e4f-05be-44d1-a503-fed82b4da974"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ea560bcb-f930-4f42-ae45-3a60f36fdbb7"}}}], "length": {"value": 0.020193, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ef5666b6-f1d1-4f2d-821e-4d9e2a1463fd", "name": "l(r:p1rdt8201lv-p1rlv17416)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76e33e4f-05be-44d1-a503-fed82b4da974"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64a56527-23a9-4229-aa25-f6a45f2187f4"}}}], "length": {"value": 0.020193, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cd54109f-3a49-4194-850b-5de8de484600", "name": "l(r:p1rdt9055lv-p1rlv19616)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c1f6cd8-cde1-45cc-87ca-1355efa38077"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be1b9922-2426-4726-9e5a-bcd33f444b57"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "c2a1e423-e43a-4b10-bdcb-48a75c970e7c", "name": "l(r:p1rdt9086lv-p1rlv19683)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "afb4c195-8bb6-47d5-88f3-76adb9cda250"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19894180-0890-4585-b4e2-55500af3c41a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "4372152f-0c65-44f9-895a-702b26f19bc7", "name": "l(r:p1rdt16394lv-p1rlv37689)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40b03cbe-470d-493a-854a-900557ac20c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f827fe9e-1ffe-456c-a57b-c3374aef8ad8"}}}], "length": {"value": 0.04723960000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "524c37c2-27e8-46cc-b729-44ebdf5bd414", "name": "l(r:p1rdt16394lv-p1rlv37691)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40b03cbe-470d-493a-854a-900557ac20c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "da3cd593-6f05-41ba-9609-f6f1e307e998"}}}], "length": {"value": 0.00410964, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4c9840fc-3d55-44fc-8db0-51dd82d5d450", "name": "l(r:p1rdt16394lv-p1rlv37703)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "40b03cbe-470d-493a-854a-900557ac20c8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "01c9efda-0adf-4932-8f54-2938964371d2"}}}], "length": {"value": 0.0432047, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a76599e2-b880-4448-9ff7-838401b7bccf", "name": "l(r:p1rdt16404lv-p1rlv37710)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38b0bd7c-0898-497f-bb24-4add0fd92932"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38bda697-2888-467e-bab0-62896a62503f"}}}], "length": {"value": 0.0546394, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "ffd4c0f2-984f-48ca-ae4a-2d2b8d5eb0bf", "name": "l(r:p1rdt16404lv-p1rlv37732)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "38b0bd7c-0898-497f-bb24-4add0fd92932"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f8d998a0-628e-4009-a6c8-07af906f6d43"}}}], "length": {"value": 0.0546394, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0eeb7dd7-662c-47a3-adc7-5124f65037a5", "name": "l(r:p1rdm37174-p1rlv37776)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58dce206-0571-4a37-b24b-2e674e0c0d3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b24da1e-9a6e-4545-9ad4-a9f0e9675fd1"}}}], "length": {"value": 0.020713, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9d4adf81-a656-46b4-8fdf-bcdddc2d9c0e", "name": "l(r:p1rdm37174-p1rdt16424lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23775c66-0b90-443d-8566-491405876e9d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58dce206-0571-4a37-b24b-2e674e0c0d3b"}}}], "length": {"value": 0.0336785, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "2366cce2-64c7-41db-b323-61f0fe2e5dc7", "name": "l(r:p1rdm37175-p1rlv37778)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d21a9584-0fe7-48a6-a46e-ac33e948a471"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5aaed5d-8312-4707-a047-634e433bf49f"}}}], "length": {"value": 0.0194998, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "ef783c84-43f7-4a0a-936a-3aaf472a6fb0", "name": "l(r:p1rdm37175-p1rdt16424lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23775c66-0b90-443d-8566-491405876e9d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d21a9584-0fe7-48a6-a46e-ac33e948a471"}}}], "length": {"value": 0.0285662, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "8694b9ce-6cbf-4036-a00c-87331245e895", "name": "l(r:p1rdt16427lv-p1rlv37782)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "980376ed-54fd-434c-b58e-0bbd6eaa9954"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d7181ee-ef64-4ded-b619-00ac09d55bf5"}}}], "length": {"value": 0.00573548, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "4eae6c4e-f0c8-47ad-9770-7091587932fd", "name": "l(r:p1rdt16603lv-p1rlv38046)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26bc650a-6838-4320-8afa-b8d2f22e96e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10be49a0-301a-4c7e-8ab7-49c14e483079"}}}], "length": {"value": 0.0415295, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "192935c2-108d-4a02-b3ff-d3ac800226fe", "name": "l(r:p1rdt16603lv-p1rlv38047)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26bc650a-6838-4320-8afa-b8d2f22e96e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0935a86b-b9fb-4058-8381-a41f67d6c9dd"}}}], "length": {"value": 0.07748250000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "9dfd866d-0648-4a36-9c98-283e673729a5", "name": "l(r:p1rdt16603lv-p1rlv38052)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "26bc650a-6838-4320-8afa-b8d2f22e96e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9db6122d-1e51-46ac-9cea-ac436e189cd8"}}}], "length": {"value": 0.0376082, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f4afa825-c031-4375-9b60-796aeee0a73b", "name": "l(r:p1rdt16604lv-p1rlv38048)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d31da07-e20a-4fb8-95f4-d91450395471"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5da7ff68-5f4c-4d56-88fc-7736df03c0bf"}}}], "length": {"value": 0.0117955, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "d99baf21-59da-4cbb-9e03-56ef465544aa", "name": "l(r:p1rdt16604lv-p1rlv38050)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d31da07-e20a-4fb8-95f4-d91450395471"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cafc6c03-240d-499d-a3d8-983b554dd007"}}}], "length": {"value": 0.0117955, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "5a91da0e-f196-45f7-a32f-1a612d6a008a", "name": "l(r:p1rdt16787lv-p1rlv38414)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4a3b828-bddf-4314-b9a5-03b9dfcd2618"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a25b3511-86cf-404e-944f-273d3f94c05a"}}}], "length": {"value": 0.0187798, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "e0ebe0a0-cff4-4adc-a9c9-d828f00e3590", "name": "l(r:p1rdt16787lv-p1rlv38419)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4a3b828-bddf-4314-b9a5-03b9dfcd2618"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6e4595c-0ad9-4501-b86f-c559917d4b86"}}}], "length": {"value": 0.0187798, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "707a4e95-c971-4116-beca-a5ce262f9535", "name": "l(r:p1rdt16790lv-p1rlv38417)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9c261090-bc22-4d81-9a9e-75227cd7c99e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "201112bb-3dc7-4a15-9af6-155626ac1ae5"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "cd1a8186-c9d0-42df-b760-b1b95294ef03", "name": "l(r:p1rdt16847lv-p1rlv38535)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1abef1d-4ffc-4696-91ca-e81ac36cce61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a0764c32-4f46-473a-9a72-cccc45ae28d7"}}}], "length": {"value": 0.048719200000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4f800f6e-aceb-490a-af1d-44e393867585", "name": "l(r:p1rdt16847lv-p1rlv38536)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e1abef1d-4ffc-4696-91ca-e81ac36cce61"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ff930f9-63f0-4cab-b74a-3db7eb99f9eb"}}}], "length": {"value": 0.048719200000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b4b5a2d0-160e-402a-b64c-8588848606d6", "name": "l(r:p1rdt16911lv-p1rlv38638)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0df1550a-7e69-42e9-8059-3a36ecb3d253"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a3851f7-2dd3-447b-918f-7a8c954f21d1"}}}], "length": {"value": 0.00340852, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "3b3117b3-95cd-4c2a-824d-0ca04943f253", "name": "l(r:p1rdt383-p1rdt384)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d49257c8-f8eb-4024-9c02-461d18cdd3d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d8cd980-268f-4adb-a6ee-70edf7784542"}}}], "length": {"value": 0.318116, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "93296b51-3b73-4395-b23e-a1fae2d4b519", "name": "l(r:p1rdt383-p1rdt384)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d8cd980-268f-4adb-a6ee-70edf7784542"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7adf2f4b-f0fd-4c53-abcf-d90fe1a2b4c4"}}}], "length": {"value": 0.509093, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c81291a8-f04b-4694-98f0-a6fbd57c43e6", "name": "l(r:p1rdt383-p1rdt7300)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9240d01-bf5d-41ed-8c53-c1f04af1a236"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ac1506-77e9-4b90-ad3d-18be099063a9"}}}], "length": {"value": 0.32156200000000007, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1921e62c-1311-4331-a4a5-2237faa7cb47", "name": "l(r:p1rdt7299-p1rdt7316)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d065da7b-7e88-4e63-a47c-959f4d4c6e1c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6322bf4d-0976-4bae-94c0-f76f83ccb9bf"}}}], "length": {"value": 0.0919841, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bc608943-95fd-47cb-acc2-7387939774bf", "name": "l(r:p1rdt7299-p1rdt7321)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b468be25-1324-46ab-9424-887741ca1134"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d065da7b-7e88-4e63-a47c-959f4d4c6e1c"}}}], "length": {"value": 0.051956600000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "46835e0d-5eec-4eb7-8862-1b1840832c2f", "name": "l(r:p1rdt7308-p1rdt7321)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2e605b4-fe7a-4571-947d-8ae19de627d8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b468be25-1324-46ab-9424-887741ca1134"}}}], "length": {"value": 0.0493128, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c9fea982-3a6d-4605-ba75-13103b955dfa", "name": "l(r:p1rdt7294-p1rdt7308)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a955da2d-e212-4026-b1fb-0021a04ded07"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2e605b4-fe7a-4571-947d-8ae19de627d8"}}}], "length": {"value": 0.06536220000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4ababa0f-34aa-4a8d-9560-2cde2aac808b", "name": "l(r:p1rdt7294-p1rdt7303)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6f24e3a-088a-4d1b-8292-03015289d88e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a955da2d-e212-4026-b1fb-0021a04ded07"}}}], "length": {"value": 0.3131880000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6ccf7fc6-714e-490d-b5be-b1876e6189b0", "name": "l(r:p1rdt7303-p1rdt7317)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48efebbb-c70a-47d3-aae3-0e39088fc455"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e9980c6-3edc-4b4a-be98-cec731419c30"}}}], "length": {"value": 0.34252800000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f7453bad-bc6b-42fc-98f0-7a998cf4dcae", "name": "l(r:p1rdt7303-p1rdt7317)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e9980c6-3edc-4b4a-be98-cec731419c30"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6f24e3a-088a-4d1b-8292-03015289d88e"}}}], "length": {"value": 0.0175612, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "2fbd6f9c-e000-4cd5-97b9-c10833bf3ef6", "name": "l(r:p1rdt7300-p1rdt7317)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05f14a3e-053e-4b65-b962-da7804b9e2c1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48efebbb-c70a-47d3-aae3-0e39088fc455"}}}], "length": {"value": 0.19776300000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "32e79415-33cb-4732-b18b-558714277e5f", "name": "l(r:p1rdt6488-p1rdt7300)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47f8ed28-4bff-47d9-8ffe-4509e9c5b7fc"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b96c1e20-68ac-4548-a068-86483c7fa921"}}}], "length": {"value": 0.249926, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a5a2b4bb-a84e-4fbd-8dfa-9a13f2336af4", "name": "l(r:p1rdt6488-p1rdt7300)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b96c1e20-68ac-4548-a068-86483c7fa921"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05f14a3e-053e-4b65-b962-da7804b9e2c1"}}}], "length": {"value": 0.473615, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7a97e04c-3261-43b6-9af9-b42fd68f65e5", "name": "l(r:p1rdt7795-p1rdt9086)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bee93ff6-6ff8-4572-b339-c8e897dac81b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "75ee3b24-7407-45ba-94d5-abe187306f13"}}}], "length": {"value": 0.841194, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f85e851f-dc0f-4e6f-a583-3f1ae28d2fe2", "name": "l(r:p1rdt7757-p1rdt7795)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0cd22d3e-1e2a-4a99-9967-b9df95837915"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bee93ff6-6ff8-4572-b339-c8e897dac81b"}}}], "length": {"value": 0.262663, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c80754fc-5960-4d67-a8f1-a5785ee8c97b", "name": "l(r:p1rdt6261-p1rdt6262)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53e5fee4-5a31-448e-8bd0-d8996468d085"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c00c7b1-0aec-4669-9679-cbc1476e0526"}}}], "length": {"value": 0.107372, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6d1cc6e8-e5d0-4689-a499-12aef7ccd279", "name": "l(r:p1rdt6261-p1rdt6262)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6c00c7b1-0aec-4669-9679-cbc1476e0526"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf092ec9-ecda-4216-9ac0-0bc035973515"}}}], "length": {"value": 0.0187886, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a9a90a2f-c40a-4110-9de4-a8cb8e889ceb", "name": "l(r:p1rdt6261-p1rdt6263)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53e5fee4-5a31-448e-8bd0-d8996468d085"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c61df077-693e-4e67-aea6-ee60b99406d1"}}}], "length": {"value": 0.228694, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f2d330e4-2f6f-42b5-a13b-cc2a94adeb93", "name": "l(r:p1rdt6261-p1rdt6266)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e22d08f0-2afc-426a-a0c0-6b00cc1103aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cab917a3-5cc2-46d5-9cee-971591841f12"}}}], "length": {"value": 0.435404, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bae0a560-3e11-4f98-b155-63857b58ce6c", "name": "l(r:p1rdt6261-p1rdt6266)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cab917a3-5cc2-46d5-9cee-971591841f12"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "53e5fee4-5a31-448e-8bd0-d8996468d085"}}}], "length": {"value": 0.154284, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "38839979-b995-4ab9-be30-6ae67a71c723", "name": "l(r:p1rdt6264-p1rdt6266)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e22d08f0-2afc-426a-a0c0-6b00cc1103aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4a03d20d-664a-4e80-abec-a36910787829"}}}], "length": {"value": 0.0739832, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1bd83f42-c21d-47a8-a7a9-1c20e7f83539", "name": "l(r:p1rdt6266-p1rdt6267)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e22d08f0-2afc-426a-a0c0-6b00cc1103aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b6508ce-e51b-4173-8b54-3f3eb7a2cd71"}}}], "length": {"value": 0.325456, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "286e59cc-f63b-468b-8d9a-61393db7e1ee", "name": "l(r:p1rdt6266-p1rdt6267)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9b6508ce-e51b-4173-8b54-3f3eb7a2cd71"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a1d9cfa7-0024-4896-a263-2715086f2ad6"}}}], "length": {"value": 0.120044, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0f94cfbd-4761-471c-9562-5e218d822505", "name": "l(r:p1rdt6266-p1rdt8174)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d07105ef-1ba3-4775-aeb4-650b5ea8736e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e22d08f0-2afc-426a-a0c0-6b00cc1103aa"}}}], "length": {"value": 0.262539, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0ea0f6d8-1d8a-446a-b9d5-e7e260e8acd3", "name": "l(r:p1rdt181-p1rdt66)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79d0fee6-369b-4f95-a2d2-cd05232652e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24681ab1-3904-4509-85e6-d9bb1dba4c8e"}}}], "length": {"value": 0.20085399999999998, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "77e9c9e8-25e0-454f-8acc-7bdc292d928a", "name": "l(r:p1rdt253-p1rdt275)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d4e6a87-0313-419f-8feb-7ea3a29f59ae"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1a85646-be2b-4b15-9c2f-cc603c7e06df"}}}], "length": {"value": 2.31966, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "dfe7b021-ea88-4223-a261-a2701064e836", "name": "l(r:p1rdt275-p1rdt68)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb9e5f0f-8bcf-4019-a786-3f24334e9ae7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8435bee2-05ea-4208-9520-809129624d70"}}}], "length": {"value": 0.43729, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "63205bf8-f4aa-4db4-9485-c23b17d81f7d", "name": "l(r:p1rdt275-p1rdt68)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8435bee2-05ea-4208-9520-809129624d70"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0d4e6a87-0313-419f-8feb-7ea3a29f59ae"}}}], "length": {"value": 0.250359, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "be6f7a14-ab8c-4e37-a3ed-5fabff553d05", "name": "l(r:p1rdt280-p1rdt68)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9cb7919-b8bd-46c1-a173-90a5d241c46e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eb9e5f0f-8bcf-4019-a786-3f24334e9ae7"}}}], "length": {"value": 0.601429, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "eb7699dc-41c5-4cce-98f5-4ae362b4e94f", "name": "l(r:p1rdt280-p1rdt281)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac745c6f-6e78-4a68-affa-649f91d3aa7c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4425707e-f2b0-419f-828e-a4642ee34b5a"}}}], "length": {"value": 0.0687501, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "72c50a17-a34a-42f4-8b31-08b3bb5f9d75", "name": "l(r:p1rdt280-p1rdt281)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4425707e-f2b0-419f-828e-a4642ee34b5a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9cb7919-b8bd-46c1-a173-90a5d241c46e"}}}], "length": {"value": 1.11596, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "727137fb-8c02-4156-8941-76e9d1959c6a", "name": "l(r:p1rdt181-p1rdt281)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79d0fee6-369b-4f95-a2d2-cd05232652e3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac745c6f-6e78-4a68-affa-649f91d3aa7c"}}}], "length": {"value": 0.20523500000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "27e2b305-6b95-45b4-975d-854d614df5dd", "name": "l(r:p1rdt181-p1rdt297)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2fddf29e-6eef-4c60-ad8b-4580440973b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d87f56c0-0a3f-4a94-8f60-1ece461290d0"}}}], "length": {"value": 0.5067780000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "baaa7a29-c4f4-4a42-9496-71615246d038", "name": "l(r:p1rdt3776-p1rdt3777)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "170a2bcb-d7ce-4617-855b-9111b84262ed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f9af980-79c4-4daf-b8fc-44e02953f98b"}}}], "length": {"value": 0.28751, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ab81c681-02cd-4d20-a59a-bf08c0860df2", "name": "l(r:p1rdt270-p1rdt3776)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7eca59ac-01f1-40d7-a0ec-51f355285e01"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6168ebbc-8fd5-49a0-94db-887814eceaba"}}}], "length": {"value": 0.108215, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "07586677-bd64-4204-9ced-d7f05aca7653", "name": "l(r:p1rdt270-p1rdt3776)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6168ebbc-8fd5-49a0-94db-887814eceaba"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "170a2bcb-d7ce-4617-855b-9111b84262ed"}}}], "length": {"value": 2.4603700000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "263d110f-a14b-4b87-b223-8da955f62175", "name": "l(r:p1rdt270-p1rdt298)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2c76250-d7ea-4da4-8008-dac1a579e974"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac7c613f-190c-493e-8e89-3ef48e8efdb9"}}}], "length": {"value": 0.28969, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ce9a3964-79b1-4db7-a902-c27cd390c975", "name": "l(r:p1rdt297-p1rdt298)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d32493ec-06be-48ef-959e-779c79c507a3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a468f13-c61f-4c01-aa27-c75fb02030e0"}}}], "length": {"value": 0.19214800000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b7b9dea7-7dc0-419e-b621-97cdac97877f", "name": "l(r:p1rdt297-p1rdt385)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91f76b91-e00a-4a88-8ee8-ec403c2c7d96"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d32493ec-06be-48ef-959e-779c79c507a3"}}}], "length": {"value": 1.01401, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "724c28f1-72e4-4cfa-a5b6-f43bf9859db4", "name": "l(r:p1rdt252-p1rdt385)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22179eaa-fd19-4619-8b31-52bcb36ec683"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "91f76b91-e00a-4a88-8ee8-ec403c2c7d96"}}}], "length": {"value": 1.1732, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "026f2218-a9fc-4fcc-8f34-747194feeaa4", "name": "l(r:p1rdt251-p1rdt254)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9c899bc-796a-4e92-88db-6aa11f8777cb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ab802e3-3a0a-413c-8865-e3b3d08e44a8"}}}], "length": {"value": 0.0898381, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0beb9ff2-61e8-46cf-8fd3-44aa828803d1", "name": "l(r:p1rdt258-p1rdt262)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e28087b-b80e-4043-b0f0-0bc82c91f5e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf660777-f77e-4d9b-afff-73a84274c270"}}}], "length": {"value": 0.208153, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "01d3c056-5715-461b-9acc-d66402ab6122", "name": "l(r:p1rdt258-p1rdt261)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "209cebda-044a-42a3-b2f0-fe5b76b80643"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be0fa139-8da7-4cba-9e49-faf4a4814035"}}}], "length": {"value": 0.38624, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f2c4710f-bc68-4564-84af-92a1aa259cb5", "name": "l(r:p1rdt258-p1rdt261)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "be0fa139-8da7-4cba-9e49-faf4a4814035"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e28087b-b80e-4043-b0f0-0bc82c91f5e8"}}}], "length": {"value": 0.00488267, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8bb69a39-5b12-4e4f-b027-85e529e0df0b", "name": "l(r:p1rdt261-p1rdt277)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bbe3ac37-aca0-47fd-ac5d-be390cad10ab"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "209cebda-044a-42a3-b2f0-fe5b76b80643"}}}], "length": {"value": 0.627357, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f3609801-4049-4855-a8a0-afaaec9dfde2", "name": "l(r:p1rdt37-p1rdt80)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a2b529c9-4695-42f3-a0e3-69bbb34ff285"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9dcbfdc3-b597-4e9e-a86f-4d0ff396ba70"}}}], "length": {"value": 0.120434, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "aa71e0a2-36e9-45a5-8ce4-23aa9fb93fc5", "name": "l(r:p1rdt34-p1rdt77)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a9c4411-f402-464c-ad25-d439b87ef768"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "31b06630-2aae-4fe7-9e31-f911c91121cd"}}}], "length": {"value": 0.034869, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4d75f989-6c51-479c-9043-91fcc989f80c", "name": "l(r:p1rdt34-p1rdt38)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b45513a3-8e88-45e9-99d3-6d244c90c256"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a9c4411-f402-464c-ad25-d439b87ef768"}}}], "length": {"value": 0.0394108, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1116ca8a-ac78-49d1-a542-1aa99e1517ef", "name": "l(r:p1rdt31-p1rdt38)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "668d32be-c07a-4387-86a5-e9754af11e9c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b45513a3-8e88-45e9-99d3-6d244c90c256"}}}], "length": {"value": 0.11407100000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "210bf30a-f181-4110-a885-4370b8e42955", "name": "l(r:p1rdt74-p1rdt85)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b82a9a2-b1d1-44eb-a451-946643ef613d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b884fef-8b8f-4ed5-9033-b8177d1c7d70"}}}], "length": {"value": 0.06744590000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4701ebe3-0051-4850-a1be-a674e0d32c1f", "name": "l(r:p1rdt456-p1rdt489)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf205ba7-ac66-4318-aeca-c75eb96cbd1e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cee642e7-12f0-4746-841e-d8cda6fff57e"}}}], "length": {"value": 0.0171007, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7fcd71f7-07a2-4583-92de-d8b76e4fd4fb", "name": "l(r:p1rdt456-p1rdt465)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b092ee09-4c5e-46b5-8ec2-51f99254c220"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf205ba7-ac66-4318-aeca-c75eb96cbd1e"}}}], "length": {"value": 0.0831843, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3d67899c-d0bf-484f-8833-ae3a12e7848e", "name": "l(r:p1rdt46-p1rdt70)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05082892-d69e-4c8f-ba19-c2a627e1c345"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "50f3b5f3-3fb5-4fb9-b2e6-b37200af0901"}}}], "length": {"value": 0.0729594, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f96ebf1e-dadb-4961-b8fe-d0177fe34940", "name": "l(r:p1rdt458-p1rdt46)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b61caefd-d5aa-4019-9ac0-aaf8cedc71d0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05082892-d69e-4c8f-ba19-c2a627e1c345"}}}], "length": {"value": 0.139036, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b72cd657-5085-4543-b5f5-8c6a58f68b97", "name": "l(r:p1rdt52-p1rdt72)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2faff95d-f394-427a-9d62-75224f830c9e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a6fb1323-f697-4423-a70d-838056200402"}}}], "length": {"value": 0.0184816, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b002135e-3155-4d9a-b8a6-8d2e34cb07e2", "name": "l(r:p1rdt49-p1rdt72)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "137c345c-77cc-4324-bc0e-e0ba896a5f43"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2faff95d-f394-427a-9d62-75224f830c9e"}}}], "length": {"value": 0.141958, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3db69a18-f698-4e11-bb2f-e1e47b900949", "name": "l(r:p1rdt49-p1rdt56)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1d8f5898-7d36-4e40-9980-76d11ef18adb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "137c345c-77cc-4324-bc0e-e0ba896a5f43"}}}], "length": {"value": 0.148385, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "dc672da8-44a3-4894-9c60-5e070b83e7e1", "name": "l(r:p1rdt472-p1rdt56)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fa14b51-a977-4e40-8f9c-28249e576fcf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1d8f5898-7d36-4e40-9980-76d11ef18adb"}}}], "length": {"value": 0.0472436, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c228649f-9ed3-4986-8dac-f0425e9a697a", "name": "l(r:p1rdt458-p1rdt472)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b61caefd-d5aa-4019-9ac0-aaf8cedc71d0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fa14b51-a977-4e40-8f9c-28249e576fcf"}}}], "length": {"value": 0.0781062, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5f1274d2-0fdd-4db3-ba3f-daa46530bbe0", "name": "l(r:p1rdt458-p1rdt468)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04fc215c-7f3e-45e1-a49c-727b0fcdae93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b61caefd-d5aa-4019-9ac0-aaf8cedc71d0"}}}], "length": {"value": 0.11485, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f4afc337-a6c2-4125-b7fe-0719d5e891df", "name": "l(r:p1rdt50-p1rdt53)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c5d8237-0351-4eb2-83e6-13975b37bfa7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e7305e2b-0a48-4630-8b8e-c3819f1c9cd1"}}}], "length": {"value": 0.0672176, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "678b9437-c595-43ea-a97d-0017be14cc4d", "name": "l(r:p1rdt50-p1rdt59)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ea7e0bb-bdc5-429a-8889-2f12c94db72e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c5d8237-0351-4eb2-83e6-13975b37bfa7"}}}], "length": {"value": 0.04918, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "60803bca-2ed6-40da-b226-2af544fcb274", "name": "l(r:p1rdt40-p1rdt59)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "577124ac-ea2b-4a60-be47-14b0f5db305e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ea7e0bb-bdc5-429a-8889-2f12c94db72e"}}}], "length": {"value": 0.0516608, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c2559856-65db-4f83-b07d-064dcaedd41f", "name": "l(r:p1rdt40-p1rdt457)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12fef7fc-57f0-4494-becd-4724b84dbbcb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "577124ac-ea2b-4a60-be47-14b0f5db305e"}}}], "length": {"value": 0.0503098, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e0135291-8bce-40e5-95ba-795bc181843a", "name": "l(r:p1rdt457-p1rdt474)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d709af4b-1115-403b-a68d-76c63c93adf2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12fef7fc-57f0-4494-becd-4724b84dbbcb"}}}], "length": {"value": 0.0841745, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b7308a7d-344b-49a7-8d80-685d673ce399", "name": "l(r:p1rdt468-p1rdt474)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5814195b-dd60-4a1e-9af6-b9b84fa4c0c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d709af4b-1115-403b-a68d-76c63c93adf2"}}}], "length": {"value": 0.047055900000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f21f7000-fa58-438d-b295-aeed9c3310fb", "name": "l(r:p1rdt63-p1rdt65)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9397c58-45a1-4ec3-bd84-b4cd5b52dc80"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ab2b6727-4d87-4b00-bd49-ba7a6b1b9ce6"}}}], "length": {"value": 0.0933284, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e85cf5e4-69ad-413f-807d-77e3f696eda8", "name": "l(r:p1rdt467-p1rdt65)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ae86125-88c3-44fb-9fe9-1a5d820606f6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9397c58-45a1-4ec3-bd84-b4cd5b52dc80"}}}], "length": {"value": 0.0141041, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a1591c79-b7e3-488b-963c-3d090d44e462", "name": "l(r:p1rdt467-p1rdt469)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48179f57-b0b9-491b-b654-81583768923a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4ae86125-88c3-44fb-9fe9-1a5d820606f6"}}}], "length": {"value": 0.045227800000000005, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bf2293fa-d697-40b8-94a8-bbc3360bdc05", "name": "l(r:p1rdt464-p1rdt469)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a634585d-0c70-428e-a3b2-1ec4717d7878"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "48179f57-b0b9-491b-b654-81583768923a"}}}], "length": {"value": 0.0950357, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6164d4c1-cfac-48db-b35f-c1fee483f069", "name": "l(r:p1rdt464-p1rdt480)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e5c3d02-1cd2-45e4-90d3-10b135c65f13"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a634585d-0c70-428e-a3b2-1ec4717d7878"}}}], "length": {"value": 0.0188143, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "028d1427-12bf-4d80-a0c8-754796fbd8f3", "name": "l(r:p1rdt473-p1rdt480)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76880999-6f79-4fc6-9367-1c419eee26d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2e5c3d02-1cd2-45e4-90d3-10b135c65f13"}}}], "length": {"value": 0.100218, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0eac6646-cb23-4f01-9532-2d11c95be7b3", "name": "l(r:p1rdt453-p1rdt473)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1bb6f93-7aed-47d7-99db-7c17352a42b8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "76880999-6f79-4fc6-9367-1c419eee26d5"}}}], "length": {"value": 0.0334417, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "550c5f51-4e56-469e-a157-549ea20e8a21", "name": "l(r:p1rdt452-p1rdt453)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d51e6f65-c45c-4f10-a17f-6ef684a0a06c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1bb6f93-7aed-47d7-99db-7c17352a42b8"}}}], "length": {"value": 0.0352317, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "928cf5c6-ff32-4265-a171-caa8f2190066", "name": "l(r:p1rdt452-p1rdt466)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b20fa59a-8573-461a-9c4a-0d47e40d2601"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d51e6f65-c45c-4f10-a17f-6ef684a0a06c"}}}], "length": {"value": 0.13529, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "fd92e905-34f3-437b-8590-4225eebd2e8e", "name": "l(r:p1rdt466-p1rdt478)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64ba6716-89f9-49a4-9793-ba80ae41bcd0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b20fa59a-8573-461a-9c4a-0d47e40d2601"}}}], "length": {"value": 0.100595, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ee3e7c72-665e-47d8-af76-5876a9d9e1c5", "name": "l(r:p1rdt459-p1rdt471)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12d5c579-0570-44db-a751-8eeb92355af9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eed7e6a8-2b4a-4a54-b69a-e3e1a0614213"}}}], "length": {"value": 0.0917334, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5c3199b2-6cca-49c7-aefa-1566475579bf", "name": "l(r:p1rdt459-p1rdt462)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fcfdc5bf-1c87-42e2-8b35-1f7125d3b5ed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12d5c579-0570-44db-a751-8eeb92355af9"}}}], "length": {"value": 0.0703754, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0db2afbf-8d20-4298-92d5-5f6af25ef9eb", "name": "l(r:p1rdt462-p1rdt487)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfb0d992-ab18-4f73-933e-a01ce73ef3b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fcfdc5bf-1c87-42e2-8b35-1f7125d3b5ed"}}}], "length": {"value": 0.0779035, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e9594c65-f9cd-4dd8-801d-a56ca367ddf8", "name": "l(r:p1rdt16787-p1rdt16790)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4774ed1a-85ec-4ca0-8e9a-3b232588fb0c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d4bc644c-9875-4846-8b0f-dfa0568de623"}}}], "length": {"value": 0.0992107, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "cadfd571-1a5b-44b9-9fb5-de61bc3fedf8", "name": "l(r:p1rdt16790-p1rdt16911)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4774ed1a-85ec-4ca0-8e9a-3b232588fb0c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d29266e8-ce67-45bf-93d9-710d4684ce0b"}}}], "length": {"value": 0.388046, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "029ca061-b298-4b43-8c5a-f7ac6278b9be", "name": "l(r:p1rdt16790-p1rdt16911)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d29266e8-ce67-45bf-93d9-710d4684ce0b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "725fbd98-74ba-4143-8947-da9fdc209889"}}}], "length": {"value": 3.63254, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b2c407c7-c4ae-4f38-879d-6ee603c0a3ac", "name": "l(r:p1rdt16790-p1rdt487)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d53ff9fd-2b16-4026-88fa-2c112d4949c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a1b5b099-df99-4729-a26d-f0882e93136f"}}}], "length": {"value": 0.110567, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f2ae3c18-4521-4101-98d7-6eb006416a16", "name": "l(r:p1rdt16790-p1rdt487)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a1b5b099-df99-4729-a26d-f0882e93136f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4774ed1a-85ec-4ca0-8e9a-3b232588fb0c"}}}], "length": {"value": 5.746810000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9061f19a-d9eb-48b0-9aa6-ee230b7b9499", "name": "l(r:p1rdt484-p1rdt487)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b57b8e2b-62c2-49a0-801d-02cab8092ebd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfb0d992-ab18-4f73-933e-a01ce73ef3b2"}}}], "length": {"value": 0.0512407, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0a5c4a2b-b730-4d42-aa11-f36b01a58a20", "name": "l(r:p1rdt484-p1rdt486)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd2f4b00-6e8b-4faa-a760-7c28f8d36a36"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b57b8e2b-62c2-49a0-801d-02cab8092ebd"}}}], "length": {"value": 0.0914543, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e4317dc5-b30e-44c0-a5fc-e0c630cfe5d6", "name": "l(r:p1rdt482-p1rdt486)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10c2463d-8563-4737-aa7d-e1195c0af9f6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bd2f4b00-6e8b-4faa-a760-7c28f8d36a36"}}}], "length": {"value": 0.018752, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ea04bd86-9e92-4818-a4ff-74fa02d6a46e", "name": "l(r:p1rdt482-p1rdt485)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4064b6c-40b4-418b-95ab-4f9bb0363b14"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10c2463d-8563-4737-aa7d-e1195c0af9f6"}}}], "length": {"value": 0.103372, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "256555f0-2f34-42b5-b04a-e8766a7dd987", "name": "l(r:p1rdt476-p1rdt477)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d1eb09d-dff4-4fa3-b96f-ef59b63d6128"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5421facb-0713-404c-97e9-56669fc762b3"}}}], "length": {"value": 0.0550546, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a651515b-87f2-44e9-827e-68ed7e4d130e", "name": "l(r:p1rdt477-p1rdt479)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85acd1fb-6da3-432a-9508-855ca991641b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d1eb09d-dff4-4fa3-b96f-ef59b63d6128"}}}], "length": {"value": 0.06993920000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8f1ebb1d-e621-479d-aa1b-1d0fea5807b5", "name": "l(r:p1rdt454-p1rdt479)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "82459f47-0c6f-4173-8c35-5a9fe5db9713"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "85acd1fb-6da3-432a-9508-855ca991641b"}}}], "length": {"value": 0.0357544, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f6e2d9ab-2762-48b9-8da9-cc62bc28adae", "name": "l(r:p1rdt454-p1rdt455)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "183de04a-a665-4112-a912-1df68b61d164"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "82459f47-0c6f-4173-8c35-5a9fe5db9713"}}}], "length": {"value": 0.0689016, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4816e19f-838d-41f2-a889-d1697bb121b3", "name": "l(r:p1rdt455-p1rdt460)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59b616e5-76b8-406c-843f-5c71398af81b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "183de04a-a665-4112-a912-1df68b61d164"}}}], "length": {"value": 0.0565594, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8ca3ee16-bba0-44b3-a3dd-3ea6a58222ea", "name": "l(r:p1rdt460-p1rdt470)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59b616e5-76b8-406c-843f-5c71398af81b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "86178159-ccd7-45a3-b711-ac237321d52a"}}}], "length": {"value": 0.106222, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "06b66ecc-6e3f-4117-a516-0557d7bb1370", "name": "l(r:p1rdt460-p1rdt483)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69b5d686-dae0-44c5-a261-f1a73bcb168e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "59b616e5-76b8-406c-843f-5c71398af81b"}}}], "length": {"value": 0.106104, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "7bdb4c42-40ee-4d95-8b61-c34a1e59a269", "name": "l(r:p1rdt483-p1rdt485)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d899b807-b194-4f65-bad5-a39e8bc61906"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69b5d686-dae0-44c5-a261-f1a73bcb168e"}}}], "length": {"value": 0.19624000000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ca24f954-e522-4093-b3ca-f315003201e2", "name": "l(r:p1rdt279-p1rdt89)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "232adbbb-2715-44be-8db5-ee062ebf4e46"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "416118a8-65b7-4d9e-90a2-454f065bfddb"}}}], "length": {"value": 0.30139, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "49d16b3e-d9c3-46dd-95bb-e5daf8e7a58c", "name": "l(r:p1rdt279-p1rdt89)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "416118a8-65b7-4d9e-90a2-454f065bfddb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac4ad276-90cb-48c0-bfd0-1f2aa0233ce2"}}}], "length": {"value": 0.197349, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a29ed3d7-71e4-416f-abb4-38952e31a0a5", "name": "l(r:p1rdt16424-p1rdt16427)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d50d3e76-470b-47c2-ada2-da944962b322"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "18e3da78-83fc-4b8e-9d45-41adb9b753ad"}}}], "length": {"value": 0.112509, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ecf392c2-a6e6-4d2c-8690-e08a70243f01", "name": "l(r:p1rdt16427-p1rdt16847)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e35a4f7-19c1-4f59-9adc-b267f6088264"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a6382a2-8c21-4cb4-a39b-3f1ac62cc705"}}}], "length": {"value": 0.160318, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b33f1be7-ab62-4068-9cdd-a6b06ddb0dd2", "name": "l(r:p1rdt16427-p1rdt16847)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a6382a2-8c21-4cb4-a39b-3f1ac62cc705"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d50d3e76-470b-47c2-ada2-da944962b322"}}}], "length": {"value": 3.5139, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "81012bf1-6b78-4db4-9e2c-bad624e98440", "name": "l(r:p1rdt16404-p1rdt16847)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61d5dee2-30f8-434d-8c03-76bccff72549"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e35a4f7-19c1-4f59-9adc-b267f6088264"}}}], "length": {"value": 1.15724, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9ae94c4c-3829-4c79-9e4a-a9d47c147dd6", "name": "l(r:p1rdt16394-p1rdt16404)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5b51836-1807-4fab-b877-94a62021569f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "61d5dee2-30f8-434d-8c03-76bccff72549"}}}], "length": {"value": 0.518625, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a4046167-8caa-4f89-90f0-2f76d4ead86f", "name": "l(r:p1rdt16394-p1rdt16603)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5a9e0f5-d824-4a76-a4f0-88aab072280e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5b51836-1807-4fab-b877-94a62021569f"}}}], "length": {"value": 0.709035, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3583561b-9771-4681-a564-fd0842692302", "name": "l(r:p1rdt16603-p1rdt16604)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98a946e8-3c8a-49ec-be8a-5610c7fc596c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5a9e0f5-d824-4a76-a4f0-88aab072280e"}}}], "length": {"value": 0.17277, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "906bae77-46ff-4ffe-aa1a-8abca937d44b", "name": "l(r:p1rdt16604-p1rdt257)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ef71bd7-4c82-4296-a6ac-64516ffe96c5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "282d8a89-8b14-476b-9e55-b310d8b9396d"}}}], "length": {"value": 0.261511, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "fd814da9-2a6f-4e0b-b2a0-78a6ae1902b8", "name": "l(r:p1rdt209-p1rdt257)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcb27aab-e828-41a6-ad98-d197897a1a69"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fb307f7-3690-4931-999a-4daab4d8c9e5"}}}], "length": {"value": 0.76493, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "071d214f-abee-4f75-a132-0f7658f857bb", "name": "l(r:p1rdt209-p1rdt210)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d782d5e-3960-415c-9e33-6742777a5a0a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dcb27aab-e828-41a6-ad98-d197897a1a69"}}}], "length": {"value": 0.184587, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "530e99b6-8a7f-4641-903b-78a595344f17", "name": "l(r:p1rdt211-p1rdt278)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9401940-26a4-40f3-9b9a-5231a5c4e171"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b89bfea1-97cd-41f7-af59-9602a3fc6c06"}}}], "length": {"value": 0.23979600000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d122d673-6fba-4f7f-84e6-34ad0b010b7b", "name": "l(r:p1rdt210-p1rdt211)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d782d5e-3960-415c-9e33-6742777a5a0a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b9401940-26a4-40f3-9b9a-5231a5c4e171"}}}], "length": {"value": 0.156188, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "59cdecc0-9e7a-45b1-97e7-6faaaa4f4ffa", "name": "l(r:p1rdt210-p1rdt44)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1be5e34-ad5e-4c78-8067-8e0194c661a4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5d782d5e-3960-415c-9e33-6742777a5a0a"}}}], "length": {"value": 1.1888300000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "11448296-bdc4-4e49-9f35-5b5f6fcea1ef", "name": "l(r:p1rdt259-p1rdt44)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0b5743e-c3fd-49c7-879e-9be7d00c480f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33a0a070-9cce-4a82-bd22-24a65f02ef97"}}}], "length": {"value": 0.515436, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "929db262-2207-4a98-873f-3fe8228c418b", "name": "l(r:p1rdt43-p1rdt47)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7728581d-66fc-4e7e-b2b0-85fa02c90523"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1ea0531d-530c-4088-86a1-3de96a8938ea"}}}], "length": {"value": 0.165779, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "8725d8ec-6b1e-43d3-aac1-c50e038ef687", "name": "l(r:p1rdt48-p1rdt51)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1667a8c6-aeb4-4f22-97b8-62ffefcc12a4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4f5cef5c-bcaf-4cd9-afbb-a18bd14dfcd4"}}}], "length": {"value": 0.04269860000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ef4f28ba-8efb-4df9-b243-d434142431d2", "name": "l(r:p1rdt43-p1rdt48)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7728581d-66fc-4e7e-b2b0-85fa02c90523"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1667a8c6-aeb4-4f22-97b8-62ffefcc12a4"}}}], "length": {"value": 0.175272, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5cc6da99-b1cd-4ddb-a42e-7a75db0bf7a7", "name": "l(r:p1rdt43-p1rdt60)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d99e903-3536-4a73-b0d5-ca11f5af6e32"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7728581d-66fc-4e7e-b2b0-85fa02c90523"}}}], "length": {"value": 0.0427769, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6df6cf40-acb9-42fb-99e3-a21ce4101b90", "name": "l(r:p1rdt58-p1rdt60)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a4ccf80-2611-4089-9353-439809aa7854"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7d99e903-3536-4a73-b0d5-ca11f5af6e32"}}}], "length": {"value": 0.0448322, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c70146f3-efa7-47d1-9cbb-88314168e430", "name": "l(r:p1rdt58-p1rdt69)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7238345a-1fc7-4f3f-bc8b-88cf7582c75c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2a4ccf80-2611-4089-9353-439809aa7854"}}}], "length": {"value": 0.0519836, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "cfb6c001-f792-4ff8-95cf-625dea85b422", "name": "l(r:p1rdt61-p1rdt71)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bcea1fd6-3c51-48af-8528-d3d7bc8e4f01"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "744725a8-af2a-47cf-948f-9d453a932e32"}}}], "length": {"value": 0.0913144, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "98b2bf94-0765-4f57-860d-b02450dd0b62", "name": "l(r:p1rdt150-p1rdt71)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eab6b8c5-ee7a-4779-b5eb-5205dbe5253c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf5b238a-832f-4f45-8a36-2248549e1723"}}}], "length": {"value": 0.0753659, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d510bfdb-9843-422e-8bb1-2f789219abfc", "name": "l(r:p1rdt150-p1rdt71)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cf5b238a-832f-4f45-8a36-2248549e1723"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bcea1fd6-3c51-48af-8528-d3d7bc8e4f01"}}}], "length": {"value": 1.27669, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "de6d22bc-1b8f-4f30-bb8b-c8da620b8eba", "name": "l(r:p1rdt374-p1rdt376)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f2a0358-b10d-4b62-8f8d-9a5054fae87d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d425a00d-c0e9-465d-9d9b-af4d64708fba"}}}], "length": {"value": 0.108011, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ff7901c8-0aff-456b-8d81-a1b8d4a2f3b2", "name": "l(r:p1rdt335-p1rdt376)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0de112ae-d04a-4673-98af-0699e4890429"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0f2a0358-b10d-4b62-8f8d-9a5054fae87d"}}}], "length": {"value": 0.20898, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5298fbca-8076-473f-8580-b288d0c98374", "name": "l(r:p1rdt415-p1rdt417)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "101c6236-a474-45c8-b065-f5fa045b1107"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "71fa675e-bc20-46f7-b6f1-c88962f9f3cb"}}}], "length": {"value": 0.074738, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e5c8a281-4e52-4e82-9f86-f4ff7e5c363d", "name": "l(r:p1rdt415-p1rdt419)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19116f3c-29ae-4819-ba72-dd0f8afa5078"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "101c6236-a474-45c8-b065-f5fa045b1107"}}}], "length": {"value": 0.232463, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d9a13636-4929-4a92-891e-92960b15b975", "name": "l(r:p1rdt180-p1rdt5098)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9100fbd6-863e-48b2-94ed-aca1ef0947bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5258d4de-be4c-478d-b752-7f4efb0af0a5"}}}], "length": {"value": 0.41780500000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d3025355-e4bb-43e1-8a1f-b9bd5316b188", "name": "l(r:p1rdt6578-p1rdt6584)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9f273a36-c30d-4962-81f4-26f8d20e1cf4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4e257530-1fe2-410b-83a1-57789e6ddeda"}}}], "length": {"value": 0.0679586, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "9aa5d5e1-1d2f-4b82-a77d-c3f2172ae856", "name": "l(r:p1rdt6584-p1rdt6588)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9f273a36-c30d-4962-81f4-26f8d20e1cf4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1648fe3-a7f9-47aa-b168-d2b56cf220e7"}}}], "length": {"value": 0.0883424, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1eba036d-0e03-407a-85b6-8ba160dad1b3", "name": "l(r:p1rdt6590-p1rdt6591)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1d0a85a-62dc-46d2-bae1-d43d07743a34"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5291ea2b-6990-407b-b8d4-d6868bf37310"}}}], "length": {"value": 0.043231000000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a5bf29ac-89bd-4638-b20b-ed48bd580674", "name": "l(r:p1rdt6584-p1rdt6591)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9f273a36-c30d-4962-81f4-26f8d20e1cf4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1d0a85a-62dc-46d2-bae1-d43d07743a34"}}}], "length": {"value": 0.125784, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f6953e73-a087-4102-a892-1ebe433cef19", "name": "l(r:p1rdt6584-p1rdt6587)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d77add8e-ba22-4b44-9c0b-0bddc251a573"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b918e583-d163-4136-aaf8-62085c7b0c17"}}}], "length": {"value": 0.115903, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f95cb8d3-6bac-4f3f-9987-04072432b638", "name": "l(r:p1rdt6584-p1rdt6587)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b918e583-d163-4136-aaf8-62085c7b0c17"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9f273a36-c30d-4962-81f4-26f8d20e1cf4"}}}], "length": {"value": 0.0307942, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f6679ba4-efdc-4874-8d11-4cf6f748a362", "name": "l(r:p1rdt6580-p1rdt6587)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68298e92-fca3-44e9-9271-f79be47c9c63"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d77add8e-ba22-4b44-9c0b-0bddc251a573"}}}], "length": {"value": 0.286666, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "818206bb-ebe5-4922-a8c2-df51bbeaebf3", "name": "l(r:p1rdt5098-p1rdt6580)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9100fbd6-863e-48b2-94ed-aca1ef0947bd"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68298e92-fca3-44e9-9271-f79be47c9c63"}}}], "length": {"value": 0.782623, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "de8392a4-82a2-4c6f-9329-507a13f1a963", "name": "l(r:p1rdt5098-p1rdt8169)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb3d775d-8d92-498b-989c-387278ec8e9e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9100fbd6-863e-48b2-94ed-aca1ef0947bd"}}}], "length": {"value": 0.639283, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "76bbbb7c-66cd-4a27-99f1-bb859a6066fd", "name": "l(r:p1rdt414-p1rdt418)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16b7f1e9-3405-4c5f-96c7-d5c08d791907"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3034e62-dd19-4ecb-bb39-6d0566e3a2ef"}}}], "length": {"value": 0.140409, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1a1011d6-d015-42ba-ac6e-da7e2a76d943", "name": "l(r:p1rdt416-p1rdt418)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16b7f1e9-3405-4c5f-96c7-d5c08d791907"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba78164d-d6ae-413b-8d24-067d8d38b28f"}}}], "length": {"value": 0.317261, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ddd205c9-12db-4ebd-8427-ef30fb02d0cd", "name": "l(r:p1rdt416-p1rdt418)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba78164d-d6ae-413b-8d24-067d8d38b28f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d16d5f5e-a376-4e39-a845-d2cde8800da3"}}}], "length": {"value": 0.00719095, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1ef9f953-073c-41dc-9fab-1bb29279ed90", "name": "l(r:p1rdt418-p1rdt8201)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e3d41a7-06a4-460b-aa6c-3a60c8d2de10"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16b7f1e9-3405-4c5f-96c7-d5c08d791907"}}}], "length": {"value": 0.383696, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "52d6e202-09f8-43f8-a1e1-d5a09e7a420b", "name": "l(r:p1rdt8180-p1rdt8201)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63928702-c44a-4e83-9cca-7ce77bdbd2b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e3d41a7-06a4-460b-aa6c-3a60c8d2de10"}}}], "length": {"value": 0.144684, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1b5efc51-00cf-4947-b82a-1d0bc2f4a0ce", "name": "l(r:p1rdt6265-p1rdt9055)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "246ad62e-5a10-4031-94e7-1732f58f1da9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cd9ea283-dbd2-4f38-b298-86a191c99bd2"}}}], "length": {"value": 0.418878, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d2ad08b2-3802-428b-90bc-4116ddde21dc", "name": "l(r:p1rdt6265-p1rdt9055)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cd9ea283-dbd2-4f38-b298-86a191c99bd2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d316c13-77c1-4412-baf9-801f7e5ae407"}}}], "length": {"value": 0.0741307, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "6784aa1f-ad7a-4d72-bb32-3a288b673f0f", "name": "l(r:p1rdt5560-p1rdt9055)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30adfcd5-405b-47ea-be54-55c5a47c835f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "708f65d6-b869-4d26-930d-0e669caf4ffb"}}}], "length": {"value": 0.254007, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "fc1f504a-bedc-4016-b92a-65b5bc1fe559", "name": "l(r:p1rdt5560-p1rdt9055)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "708f65d6-b869-4d26-930d-0e669caf4ffb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "246ad62e-5a10-4031-94e7-1732f58f1da9"}}}], "length": {"value": 0.116066, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "660f83ca-a09b-4b56-aa68-675d218b0194", "name": "l(r:p1rdt7737-p1rdt7753)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d2ea25e-3d48-4b1d-9e52-768752de2e09"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d142315b-a247-4a4d-a178-73e3c150a188"}}}], "length": {"value": 0.0669715, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "48e7142e-612f-4100-8d25-23220ea89d75", "name": "l(r:p1rdt7737-p1rdt7791)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4413ca7f-fdd1-484e-a0ba-3ff2447ebfef"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0946738d-95de-4ad6-9d56-c043cb64c0e4"}}}], "length": {"value": 0.249534, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e62453e6-b369-467e-88c6-b611ede7388d", "name": "l(r:p1rdt7737-p1rdt7791)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0946738d-95de-4ad6-9d56-c043cb64c0e4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d2ea25e-3d48-4b1d-9e52-768752de2e09"}}}], "length": {"value": 0.0184373, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "37724e03-70aa-4ea1-8b09-81dd8f5d16fa", "name": "l(r:p1rdt7286-p1rdt7791)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02351140-e632-49e2-83e4-7e5bc1c8856a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4413ca7f-fdd1-484e-a0ba-3ff2447ebfef"}}}], "length": {"value": 0.158647, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "62eb02c6-39e5-4a17-8074-8f98b78fcba3", "name": "l(r:p1rdt7286-p1rdt7289)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f8375b7-7bdd-409c-9fa1-5c13bd233364"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "02351140-e632-49e2-83e4-7e5bc1c8856a"}}}], "length": {"value": 0.04388460000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "df4ec83d-e66f-4915-88ba-7af7ae387aea", "name": "l(r:p1rdt7289-p1rdt7293)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f8375b7-7bdd-409c-9fa1-5c13bd233364"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4afa9bec-d8da-4449-ab96-9f875bae3c33"}}}], "length": {"value": 0.16261800000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a4c26044-940e-462b-9054-1e0d4b8c36e4", "name": "l(r:p1rdt5568-p1rdt7289)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c83b6ee-20fc-4ca0-a778-44735283afd5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f8375b7-7bdd-409c-9fa1-5c13bd233364"}}}], "length": {"value": 0.600473, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a4279547-718a-4091-8aa8-b7d14015a34a", "name": "l(r:p1rdt5551-p1rdt5568)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8aa126c-9b2b-4ae0-a4fc-36d4201762a0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65eb08cf-6350-410a-88c2-3b318d3a262a"}}}], "length": {"value": 0.0882294, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1369a137-ea26-496f-a49e-07fe1c36db1c"}}}}, {"uuid": "60d3b874-c356-4c2d-8bcd-365734606fc3", "name": "l(r:p1rdt5551-p1rdt5568)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "65eb08cf-6350-410a-88c2-3b318d3a262a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64aba8d5-1dd3-4741-a8ba-26801e275ba8"}}}], "length": {"value": 0.0161184, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a6b9e998-dc46-46e3-b86b-5d83295608dd", "name": "l(r:p1rdt5548-p1rdt5577)", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c49b671-0b2b-43c9-bcb5-21c7b7e716ce"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fead5749-3ba7-4ead-a604-e8adbd18f8c2"}}}], "length": {"value": 0.160305, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1369a137-ea26-496f-a49e-07fe1c36db1c"}}}}, {"uuid": "7ddab2ca-bfb1-4594-b119-011f70f0dd90", "name": "l(r:p1rdt182-p1rdt304)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c51ccb17-eed6-4ce0-b839-e7b26001fe3e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "08e378d4-4ca6-4c9e-93fa-36ff87a3cf0f"}}}], "length": {"value": 0.7293, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "129d30ae-597e-45cf-b893-7a0bf9dba703", "name": "l(r:p1rdt304-p1rdt305)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b936973-54dc-41e7-a413-8932c31f0793"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c51ccb17-eed6-4ce0-b839-e7b26001fe3e"}}}], "length": {"value": 0.171066, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "86281a7e-9023-4f94-a293-57e7d50db505", "name": "l(r:p1rdt303-p1rdt305)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9672c49b-8316-4907-b204-7505483210b0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7b936973-54dc-41e7-a413-8932c31f0793"}}}], "length": {"value": 0.3440750000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "312c6354-e82f-404e-8e44-2dcf1c65f8bf", "name": "l(r:p1rdt177-p1rdt303)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ad84ef4-4dcc-42f7-99ed-b8d21cebc465"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9672c49b-8316-4907-b204-7505483210b0"}}}], "length": {"value": 0.47439500000000007, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f5774d9c-24b9-411c-a015-e6e4b59caef7", "name": "l(r:p1rdt178-p1rdt306)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57a78c71-e5a8-4dfd-8359-e368b7b198fa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6912a245-ac1c-4ddd-b021-3bc35cbbe2c5"}}}], "length": {"value": 1.21943, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c7cb6ba7-cba6-40f8-a51e-07fb728cc8a3", "name": "l(r:p1rdt177-p1rdt306)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ad84ef4-4dcc-42f7-99ed-b8d21cebc465"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "57a78c71-e5a8-4dfd-8359-e368b7b198fa"}}}], "length": {"value": 0.644981, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "0217c83c-f2af-4c1c-ac7f-0a81411e1e63", "name": "l(r:p1rdt177-p1rdt8105)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3f91816-7c3f-4fc7-98a5-6dee55e52e9f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ad84ef4-4dcc-42f7-99ed-b8d21cebc465"}}}], "length": {"value": 1.4039100000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "2ed246a3-dfad-450b-b7f1-ab6f298571c4", "name": "l(r:p1rdt8105-p1rdt8111)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2c69fef-4afb-4bb3-9828-096b812de54a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37229b7c-80a2-4d01-af6a-818bdfcc1f54"}}}], "length": {"value": 0.0910676, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "12928856-aaca-4156-8f34-04878d8ad992", "name": "l(r:p1rdt8105-p1rdt8111)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "37229b7c-80a2-4d01-af6a-818bdfcc1f54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3f91816-7c3f-4fc7-98a5-6dee55e52e9f"}}}], "length": {"value": 0.186172, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "aa0b22a4-6d2d-44c3-bf03-9f5e189ed04f", "name": "l(r:p1rdt8111-p1rdt8146)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2c69fef-4afb-4bb3-9828-096b812de54a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc34073b-94f6-4c75-8144-8f624bac9cc7"}}}], "length": {"value": 0.0135199, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bd0c3d35-c8cb-4701-b32e-a31567ad572d", "name": "l(r:p1rdt8111-p1rdt8138)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9929e0d4-3e33-4f5f-b718-6a629cc52242"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3a54311-da27-45d7-95c3-eee07761fbe4"}}}], "length": {"value": 0.198155, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "817adbcf-58d7-4cf2-b4cb-c18d1bc0c604", "name": "l(r:p1rdt8111-p1rdt8138)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3a54311-da27-45d7-95c3-eee07761fbe4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f2c69fef-4afb-4bb3-9828-096b812de54a"}}}], "length": {"value": 0.00299557, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "95236d9f-791c-4a01-a0fd-cb767ec941fa", "name": "l(r:p1rdt251-p1rdt252)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b801037a-e1bb-4c5c-8d18-ed285c8c1d3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69b2ee46-ab5f-48c8-a26b-170ed2b57fcb"}}}], "length": {"value": 0.0455935, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "c1ec8649-6347-41c8-8e9c-1a2e0a37841e", "name": "l(r:p1rdt251-p1rdt446)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3dfe357-889d-42e0-a59a-821c9f843456"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b801037a-e1bb-4c5c-8d18-ed285c8c1d3b"}}}], "length": {"value": 0.620095, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "02b836f0-26df-4939-85a9-506b1779e82b", "name": "l(r:p1rdt468-p1rdt481)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cf3136f-6dbe-4ed7-b9cb-e9f73b191f76"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a180b972-cf0e-4a2e-9bcf-a0ad90bb3d83"}}}], "length": {"value": 0.100395, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "dcd73329-a55d-4e12-a3ff-f205c33136f3", "name": "l(r:p1rdt475-p1rdt481)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c39140c6-8892-480a-81b9-738c67ed1591"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2cf3136f-6dbe-4ed7-b9cb-e9f73b191f76"}}}], "length": {"value": 0.0369015, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "a299d137-b589-4bab-9836-867f1cdfec55", "name": "l(r:p1rdt461-p1rdt475)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc35f44e-d8d9-41d0-b014-caa3d8d7a91e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c39140c6-8892-480a-81b9-738c67ed1591"}}}], "length": {"value": 0.0590418, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "cc87ca48-40d2-40fa-9407-459ef56a38b8", "name": "l(r:p1rdt461-p1rdt478)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eba354c-f4bf-4c49-a8ad-998ab9489e5a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fc35f44e-d8d9-41d0-b014-caa3d8d7a91e"}}}], "length": {"value": 0.0960031, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d6d87a15-b966-4e10-bace-11ae16b68c35", "name": "l(r:p1rdt465-p1rdt478)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a94f7afe-e8b0-4b24-8196-6b05e98c3830"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eba354c-f4bf-4c49-a8ad-998ab9489e5a"}}}], "length": {"value": 0.0203603, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "485b7ea4-6076-4866-bc63-7950ab5f04be", "name": "l(r:p1rdt465-p1rdt488)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fa474a3-1d6b-454b-9170-6a8d13789c43"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a94f7afe-e8b0-4b24-8196-6b05e98c3830"}}}], "length": {"value": 0.148866, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "c56be5eb-6989-4184-86ff-3b60dff1d2be", "name": "l(r:p1rdt463-p1rdt488)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7637cfdb-6a14-4313-95d4-e25beba178f3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0fa474a3-1d6b-454b-9170-6a8d13789c43"}}}], "length": {"value": 0.0269677, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "85776a35-68a0-48b2-b32c-4fcf63f765bf", "name": "l(r:p1rdt463-p1rdt82)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7627cbc6-c54a-432b-8cba-59e448f6d45a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7637cfdb-6a14-4313-95d4-e25beba178f3"}}}], "length": {"value": 0.14966800000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "95bc8f10-ed30-43b9-88b7-71e259b40cd0", "name": "l(r:p1rdt78-p1rdt82)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36bfd1f1-80ca-4b7d-a68b-9aa77ceff96e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7627cbc6-c54a-432b-8cba-59e448f6d45a"}}}], "length": {"value": 0.0637409, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "9c2f5d3e-aed7-46b7-a9db-8653f9ca9dab", "name": "l(r:p1rdt78-p1rdt85)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fc415bc-f457-4e9f-bbd4-783a71b67ad6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "36bfd1f1-80ca-4b7d-a68b-9aa77ceff96e"}}}], "length": {"value": 0.0375885, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "6a1cad6b-2cac-431d-af4c-21b2a59172a9", "name": "l(r:p1rdt81-p1rdt85)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "063e25be-2abb-49ae-b459-ddd08ba93bb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fc415bc-f457-4e9f-bbd4-783a71b67ad6"}}}], "length": {"value": 0.0219108, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "90683555-cb96-4ee2-8b94-86a64832f1b8", "name": "l(r:p1rdt79-p1rdt81)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b32c9763-ddff-435b-a28c-8f65111c6cb2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "063e25be-2abb-49ae-b459-ddd08ba93bb3"}}}], "length": {"value": 0.0220447, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "372cf68c-8148-4394-a412-526fb4273f82", "name": "l(r:p1rdt76-p1rdt79)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfbb212a-9882-4468-86ac-578c93fde1d8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b32c9763-ddff-435b-a28c-8f65111c6cb2"}}}], "length": {"value": 0.0442698, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "24ae7f1a-6a8a-4a84-aed9-7438bb1bec6e", "name": "l(r:p1rdt31-p1rdt76)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7c543753-fa26-41df-b7a6-3664395c0d45"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfbb212a-9882-4468-86ac-578c93fde1d8"}}}], "length": {"value": 0.117156, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f53f5aae-c274-43c4-b7af-d3041298dfff", "name": "l(r:p1rdt31-p1rdt36)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8dcdfef-b40e-4f1c-9b7c-e84846f68c5a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7c543753-fa26-41df-b7a6-3664395c0d45"}}}], "length": {"value": 0.088569, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "e93867c8-7f0e-49a3-8db2-3f7907cc4bff", "name": "l(r:p1rdt32-p1rdt36)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "834e959c-8ee6-4fff-b1fc-54c20fc0f20b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e8dcdfef-b40e-4f1c-9b7c-e84846f68c5a"}}}], "length": {"value": 0.10601200000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "5231e2a7-fda4-48de-a8e5-a4f8a504694d", "name": "l(r:p1rdt234-p1rdt32)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80331f15-8b31-454c-a289-49cb79923252"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "834e959c-8ee6-4fff-b1fc-54c20fc0f20b"}}}], "length": {"value": 0.0518824, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "198b7f01-439d-4fea-bb64-8e615b1d0219", "name": "l(r:p1rdt233-p1rdt485)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f5ed5d5-93fc-4f3c-a78b-df7019863b67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "445f61a4-8045-4558-a3c1-bb44336737ec"}}}], "length": {"value": 0.123436, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "c8e84a6d-4476-4110-8a87-5bff5dfd82d6", "name": "l(r:p1rdt233-p1rdt236)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "190d6c51-94b6-462e-8fee-cce57f1ab66d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8f5ed5d5-93fc-4f3c-a78b-df7019863b67"}}}], "length": {"value": 0.0731224, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "ac72dac2-d88d-478e-9c53-c5d07d08999e", "name": "l(r:p1rdt234-p1rdt236)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80331f15-8b31-454c-a289-49cb79923252"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "190d6c51-94b6-462e-8fee-cce57f1ab66d"}}}], "length": {"value": 0.175361, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "bff96efe-7ad7-4117-8d5e-ed34b5e1b0d0", "name": "l(r:p1rdt234-p1rdt235)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14b85850-d83e-4a5e-83c3-ccb485bb85aa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "80331f15-8b31-454c-a289-49cb79923252"}}}], "length": {"value": 0.10401900000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "4b67aeb5-bf41-404b-b4d6-ed2773d5f4a9", "name": "l(r:p1rdt235-p1rdt30)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fa95a19-0e0a-49b3-bb86-7103fbaa4110"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "14b85850-d83e-4a5e-83c3-ccb485bb85aa"}}}], "length": {"value": 0.07237510000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "9e0dc484-5292-4398-b046-2bb0b8595c8c", "name": "l(r:p1rdt30-p1rdt35)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "edc22f66-e919-448e-b990-76033c281d43"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4fa95a19-0e0a-49b3-bb86-7103fbaa4110"}}}], "length": {"value": 0.108408, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "57e13003-4b6c-451f-b816-8653b0a58096", "name": "l(r:p1rdt35-p1rdt84)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e9f4b13-5fb5-46b2-9258-83582d47d61a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "edc22f66-e919-448e-b990-76033c281d43"}}}], "length": {"value": 0.0706611, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "30145750-aaff-48a3-b83b-9b27874f2bc3", "name": "l(r:p1rdt33-p1rdt84)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f55e4012-a11d-4883-baac-9c013aff6058"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1e9f4b13-5fb5-46b2-9258-83582d47d61a"}}}], "length": {"value": 0.08205580000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "f055d7d6-9d6d-4aa0-955c-8987e1322223", "name": "l(r:p1rdt33-p1rdt39)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a01c83d1-4adb-4b2a-8de3-441d7c1dd054"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f55e4012-a11d-4883-baac-9c013aff6058"}}}], "length": {"value": 0.0532669, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "ab5f4002-be54-4c6e-8532-bd6c2fa76205", "name": "l(r:p1rdt39-p1rdt73)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc531967-1a7b-4424-83ee-e1131c6fd94c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a01c83d1-4adb-4b2a-8de3-441d7c1dd054"}}}], "length": {"value": 0.0177535, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "664a630b-6756-439e-a71a-12b73095c4bf", "name": "l(r:p1rdt73-p1rdt75)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "510ea93c-7dd1-4fa3-ba3f-6c362856c7c1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc531967-1a7b-4424-83ee-e1131c6fd94c"}}}], "length": {"value": 0.0510053, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "17c999b3-2206-4299-a8c6-d725bd804b3c", "name": "l(r:p1rdt75-p1rdt83)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aa0b7c2-9d55-4faf-8778-76a6f23bcf3e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "510ea93c-7dd1-4fa3-ba3f-6c362856c7c1"}}}], "length": {"value": 0.0608389, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "a03c0ec0-e778-49bd-babf-57f483e5f78d", "name": "l(r:p1rdt80-p1rdt83)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b03f8e29-a5b2-4bed-b68c-219276674b6a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0aa0b7c2-9d55-4faf-8778-76a6f23bcf3e"}}}], "length": {"value": 0.10093, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "8435eda2-aebc-4043-8961-853e603285bf", "name": "l(r:p1rdt263-p1rdt80)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e26e5dc-8c98-4fcd-b125-3265eb00f3f2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b03f8e29-a5b2-4bed-b68c-219276674b6a"}}}], "length": {"value": 0.7842920000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "b8f9d0e5-0e06-4d03-a44d-6fbdf10da8a4", "name": "l(r:p1rdt263-p1rdt277)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "add5e39f-f02e-4a61-a156-d5721cec25d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6e26e5dc-8c98-4fcd-b125-3265eb00f3f2"}}}], "length": {"value": 0.731992, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "2f9e0bfb-0ba5-4693-8dbb-8500785d1fa7", "name": "l(r:p1rdt276-p1rdt277)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "186ffdfe-2346-4218-bd6b-b813ea6b3b62"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "add5e39f-f02e-4a61-a156-d5721cec25d5"}}}], "length": {"value": 0.376236, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "095deedb-f5aa-4b88-8ec2-fa9270de8eee", "name": "l(r:p1rdt44-p1rdt69)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9396562e-4f87-4e04-b248-502b851fe19e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1bf1493-fb0d-40b4-8953-42e851a128d1"}}}], "length": {"value": 0.096072, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "16c1200d-d591-4bd8-aa0f-4d52544f6dca", "name": "l(r:p1rdt44-p1rdt69)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1bf1493-fb0d-40b4-8953-42e851a128d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d9ee2ff-e2bc-4d76-b173-5ba5cc48c9b3"}}}], "length": {"value": 0.103033, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d2e808c0-fed6-463f-887f-0e7be56eabd4", "name": "l(r:p1rdt41-p1rdt69)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5b5b3ae-f657-4fd4-a311-ab1dbe9d749e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9396562e-4f87-4e04-b248-502b851fe19e"}}}], "length": {"value": 0.0379066, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "ccf449d9-5f73-457c-ad76-1fc3f639c69d", "name": "l(r:p1rdt41-p1rdt54)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a898f4c-f522-4e69-be4a-e935e339e011"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f5b5b3ae-f657-4fd4-a311-ab1dbe9d749e"}}}], "length": {"value": 0.0700668, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "0bf9bcaf-d009-493b-b258-a20b48a817ea", "name": "l(r:p1rdt42-p1rdt54)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a778171c-22a1-4320-9e3c-43888d734e34"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a898f4c-f522-4e69-be4a-e935e339e011"}}}], "length": {"value": 0.0819124, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "fe298b54-0758-4c2f-937f-b4e520788b5d", "name": "l(r:p1rdt42-p1rdt45)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29a79372-9c75-4a9c-81df-a7491b87e58a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a778171c-22a1-4320-9e3c-43888d734e34"}}}], "length": {"value": 0.109393, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "7752518c-dbd5-4bcf-98ba-736e959ee9fd", "name": "l(r:p1rdt150-p1rdt45)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12451cbc-eb14-4814-b274-12eb2241c78a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "666bb367-692a-4127-8f77-d86d651768a1"}}}], "length": {"value": 0.181242, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "1af5f53b-c460-4041-bb80-361236411275", "name": "l(r:p1rdt150-p1rdt45)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "666bb367-692a-4127-8f77-d86d651768a1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "29a79372-9c75-4a9c-81df-a7491b87e58a"}}}], "length": {"value": 1.27197, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "9f74db70-41c8-4e3a-954c-bbda4ce07e86", "name": "l(r:p1rdt150-p1rdt260)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba0ef4a3-43ba-469b-8ce8-ca7a5a984071"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e885b3e5-18fb-4454-b8e7-d82b4c72f6e8"}}}], "length": {"value": 0.105488, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "43084528-6f58-47a7-8115-80e604d313d3", "name": "l(r:p1rdt150-p1rdt260)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e885b3e5-18fb-4454-b8e7-d82b4c72f6e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12451cbc-eb14-4814-b274-12eb2241c78a"}}}], "length": {"value": 0.49255100000000007, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "19fa5caf-ed6f-48b1-aef3-26ccfa1abc3b", "name": "l(r:p1rdt260-p1rdt279)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "153bb615-5ee5-4eec-bcf7-94ea0098aeb6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ba0ef4a3-43ba-469b-8ce8-ca7a5a984071"}}}], "length": {"value": 0.693281, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "b5f6404e-7ee0-44ba-83b2-4d2a8b780d6d", "name": "l(r:p1rdt276-p1rdt279)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7140d97e-416e-47ec-9f86-46ad6f9abece"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "153bb615-5ee5-4eec-bcf7-94ea0098aeb6"}}}], "length": {"value": 0.296948, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "a22eecf7-0b6c-4b67-b1b6-ef07cf773782", "name": "l(r:p1rdt237-p1rdt276)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3ca9bee-26b0-4ef4-8555-6494ffdd6a17"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "767b59ef-ecd9-4b17-8233-2033a02b2971"}}}], "length": {"value": 0.558882, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "3aa27888-757a-4ade-a479-17348bb56293", "name": "l(r:p1rdt237-p1rdt276)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "767b59ef-ecd9-4b17-8233-2033a02b2971"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "186ffdfe-2346-4218-bd6b-b813ea6b3b62"}}}], "length": {"value": 0.599014, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "3494f392-4b57-4668-b618-de109c41f74b", "name": "l(r:p1rdt237-p1rdt445)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11571d26-573f-49f7-99fd-828dde97afd8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8c8b8f8-7a41-4d16-b509-2d7c7af9509d"}}}], "length": {"value": 0.477235, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "23768e60-635b-4d3f-be8d-50fde874d64a", "name": "l(r:p1rdt438-p1rdt445)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10620dcc-049c-4417-b4ac-922a56c0d4a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "11571d26-573f-49f7-99fd-828dde97afd8"}}}], "length": {"value": 0.109204, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "418c0e4f-5a25-445f-91f1-8a7745ad0c0b", "name": "l(r:p1rdt438-p1rdt446)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3dfe357-889d-42e0-a59a-821c9f843456"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10620dcc-049c-4417-b4ac-922a56c0d4a2"}}}], "length": {"value": 0.05910800000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "0e0c3e54-806e-4c0f-9753-303f0f99e48d", "name": "l(r:p1rdt28-p1rdt446)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e71eb2d5-cd10-498d-b9eb-ae337b2f8af6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f3dfe357-889d-42e0-a59a-821c9f843456"}}}], "length": {"value": 2.20796, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d440b633-33ea-4a79-a563-f95e7e886d44", "name": "l(r:p1rdt28-p1rdt29)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b238dc5-7d8e-4b2d-8449-4dc212d7d227"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e71eb2d5-cd10-498d-b9eb-ae337b2f8af6"}}}], "length": {"value": 0.24769, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "60bac6f6-9fdd-4815-92c7-20ba11b7d04a", "name": "l(r:p1rdt29-p1rdt335)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b07c4a6-39a7-4521-bce7-3f1ca0ff4a66"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5b238dc5-7d8e-4b2d-8449-4dc212d7d227"}}}], "length": {"value": 0.899533, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "ad61cfe0-a656-43cd-97b6-04704f1d3e5b", "name": "l(r:p1rdt335-p1rdt419)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2efeaf5-2055-4718-a064-7c5e00b7d87d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b07c4a6-39a7-4521-bce7-3f1ca0ff4a66"}}}], "length": {"value": 1.90653, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "e66e4d18-0d3a-4652-bd28-391e4e42b5ca", "name": "l(r:p1rdt419-p1rdt420)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4cf05060-0a39-49a9-a761-79fb136e2965"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81cfd2a2-295c-4b73-abba-05ffee810523"}}}], "length": {"value": 0.238058, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "e475a674-9e0e-438b-956a-b0c948b066b6", "name": "l(r:p1rdt420-p1rdt8167)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eb3d4eb-71fc-46f3-b588-d223568c411c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4cf05060-0a39-49a9-a761-79fb136e2965"}}}], "length": {"value": 0.4863970000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "cc58970e-64bc-4597-914e-37cb30e8ffc9", "name": "l(r:p1rdt8167-p1rdt8180)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c93a476-4ad5-41cd-a07b-e2ccc9ef2c3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eb3d4eb-71fc-46f3-b588-d223568c411c"}}}], "length": {"value": 0.163613, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "62e99707-ce49-47b4-a983-1959eeb7a76e", "name": "l(r:p1rdt8169-p1rdt8180)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c93a476-4ad5-41cd-a07b-e2ccc9ef2c3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6bdb2cf-9373-4d56-a5f9-cb8fa9c67e55"}}}], "length": {"value": 0.222344, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "a780ffe2-7718-4b83-b86a-e0fe3fb9d703", "name": "l(r:p1rdt8174-p1rdt8180)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "498a07ee-e12b-459a-a01f-f663a4a8428a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c93a476-4ad5-41cd-a07b-e2ccc9ef2c3b"}}}], "length": {"value": 0.527921, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "6617344b-9ba8-444d-bb97-2a58fedb9fbd", "name": "l(r:p1rdt8174-p1rdt8195)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8997dae6-8970-4762-98e9-0617375633d6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b0f9433-e0a3-458a-8687-c9cf38d0bbb3"}}}], "length": {"value": 0.115815, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "84d5b120-0d32-4f1b-a36d-b5c13c2111a5", "name": "l(r:p1rdt7757-p1rdt8195)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "081feb5c-d5d5-405e-85d4-f1dd0916fc3d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8997dae6-8970-4762-98e9-0617375633d6"}}}], "length": {"value": 0.279303, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "9ddeb1c5-3ca3-4e2d-9c80-477ec8adb6be", "name": "l(r:p1rdt5560-p1rdt7757)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68117bef-16c5-40c9-9356-76ef5c056650"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b64b7bd6-06e4-45f7-b987-efc7d09b91f8"}}}], "length": {"value": 0.322295, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "1e9bf254-9c79-4ea5-8fad-7bda32329ae5", "name": "l(r:p1rdt5560-p1rdt7757)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b64b7bd6-06e4-45f7-b987-efc7d09b91f8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "081feb5c-d5d5-405e-85d4-f1dd0916fc3d"}}}], "length": {"value": 0.349419, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "15fcd358-cd82-4f30-b9a7-7166929792fe", "name": "l(r:p1rdt5560-p1rdt5564)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8444c9ea-ff7a-4b0a-9ea6-9c18770565cb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68117bef-16c5-40c9-9356-76ef5c056650"}}}], "length": {"value": 0.08906480000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "224b5f84-1923-4354-9d26-d73c5031bd42", "name": "l(r:p1rdt5563-p1rdt5564)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad24f98d-f022-4e62-b80b-426052810759"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8444c9ea-ff7a-4b0a-9ea6-9c18770565cb"}}}], "length": {"value": 0.0604798, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "33a61b6a-9e2b-42e9-ad56-90f1398207e6", "name": "l(r:p1rdt5557-p1rdt5563)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c94489ed-4399-4dab-bab6-02b79f240f63"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fbc31b75-f942-4bae-8712-f1666d8b7f26"}}}], "length": {"value": 0.0599682, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "20b4ef91-8e73-4465-8325-4d24a3b897d5", "name": "l(r:p1rdt5557-p1rdt5565)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "efe7243f-340b-4114-be7c-f7494e78384f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bfe92e2e-285d-4c58-8e0b-a462dd73fa41"}}}], "length": {"value": 0.058444, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "6efab38c-c3e9-4312-b685-21a2d96b021e", "name": "l(r:p1rdt5561-p1rdt5565)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8bd0860f-2b3e-4c90-a571-cfc6aa649e5b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bebca5d7-2d4f-4655-a965-9faafd7a8125"}}}], "length": {"value": 0.047072, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "029915e5-6ffa-4e8a-992f-299338154773", "name": "l(r:p1rdt5551-p1rdt5561)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27ab530f-a58e-4113-80f6-63f768910204"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf97a458-469e-4609-bb33-97454e7c2b68"}}}], "length": {"value": 0.0283038, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "f198382a-0a0f-4e03-9ae9-b2efa019c2ca", "name": "l(r:p1rdt5548-p1rdt5551)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d447cf8-7b2b-45f1-8084-6fe4897e1853"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ec70f12-a676-48cd-b626-34f8d7f6a5bf"}}}], "length": {"value": 0.0368985, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "a4b33341-bd57-4d7b-b4aa-f10eebfda207", "name": "l(r:p1rdt5548-p1rdt5566)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10f43169-4b4b-4dbe-8f09-af72d427d6c7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23163dba-070c-435c-bb90-77be7ded002a"}}}], "length": {"value": 0.0390774, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "40c04881-ef90-4bbb-9776-4086b7596654", "name": "l(r:p1rdt5566-p1rdt5574)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf619f04-1fa5-4be7-8a76-669b79436d3e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c264e6de-a898-421d-a2fe-ce6548aa477e"}}}], "length": {"value": 0.00976661, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "39368021-558c-46e1-b3b2-1376e7863046"}}}}, {"uuid": "3d33cc3f-87f4-4ed0-91cc-87931b9584c8", "name": "l(r:p1rdt5574-p1rdt8138)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17b633c6-214d-4428-bded-df737f50ffb6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c8fd701-7842-49c1-b630-7ae1ad49739f"}}}], "length": {"value": 0.295682, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "596de436-8b70-4b86-90d6-c950c609a1a1", "name": "l(r:p1rdt5574-p1rdt8138)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2c8fd701-7842-49c1-b630-7ae1ad49739f"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9906676-e9b9-4d51-b1c2-a6b6fe187faa"}}}], "length": {"value": 0.00299767, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "1e2f5da7-2523-420f-9a3f-8207dba32215", "name": "l(r:p1rdt6488-p1rdt8138)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63b2f1e6-5e15-4433-85ee-ff7bb7218b96"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "548ba541-a511-486c-876c-c841a6e482af"}}}], "length": {"value": 0.512556, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "05321a30-75f0-40c2-b4b8-86477a6638ba", "name": "l(r:p1rdt6488-p1rdt8138)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "548ba541-a511-486c-876c-c841a6e482af"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17b633c6-214d-4428-bded-df737f50ffb6"}}}], "length": {"value": 1.64392, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "0aea12b8-2186-4836-85d6-b58d4342e6b6", "name": "l(r:p1rdt6488-p1rhs7_1247)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ed5e3889-e8c8-4215-adb8-9880f8937da5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63b2f1e6-5e15-4433-85ee-ff7bb7218b96"}}}], "length": {"value": 0.640605, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "56c3525d-82f8-42be-a65c-cf7759d85f2d", "name": "l(r:p1rdt5551lv-p1rlv11506)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a9dec144-ef2e-44fe-990a-c9d70b740410"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "82988650-787d-41de-bca7-4f3c08ccad15"}}}], "length": {"value": 0.0327608, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "5c2ec73d-3368-4c1c-9ef2-795598c70ec1", "name": "l(r:p1rdt5565lv-p1rlv11522)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "60dc1291-a843-4abf-bfc6-ff8afc8c0b98"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "176b348f-9ecf-4a82-bdf9-f2e5d5a07af7"}}}], "length": {"value": 0.05525650000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "6dacb7f0-677a-488e-9ecc-948c66479101", "name": "l(r:p1rdt5563lv-p1rlv11520)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a150dd3-61a4-4df9-90e2-6c72f80af819"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22054033-4e69-41b0-b321-a4d086d20574"}}}], "length": {"value": 0.0488534, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "96e610fa-0320-4fdb-a89f-9dc0244a5f46", "name": "l(r:p1rdt252lv-p1rlv440)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c5fd6466-e740-4f06-a842-798195d62154"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a23f97bc-e7ef-4f64-9e64-314f4a4e17d8"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "1d21e7c4-cfe0-4784-83b3-e620d0d749b9"}}}}, {"uuid": "3281c6b4-cd7b-405e-b82d-01608de0b3bf", "name": "padswitch(r:p1rdt5551-p1rdt5568)p1r_14627", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "514ad102-b590-4ad8-a258-2b6fa8dcbeb1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8aa126c-9b2b-4ae0-a4fc-36d4201762a0"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "6ba5defb-3101-4ef8-8d06-36719f7dad94"}}}}, {"uuid": "bf6157a4-7aa1-4ed3-b5bb-c658cc930d54", "name": "padswitch(r:p1rdt5551-p1rdt5568)p1r_14628", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64aba8d5-1dd3-4741-a8ba-26801e275ba8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c83b6ee-20fc-4ca0-a778-44735283afd5"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "b477d9d0-158a-46f2-92c2-f5870d9f433b", "name": "padswitch(r:p1rdt5548-p1rdt5577)p1r_14631", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25ee6008-ddbc-4e7b-8a57-ff38c16368a2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0c49b671-0b2b-43c9-bcb5-21c7b7e716ce"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "fa89ef5e-f965-457f-a553-4831f61b03c7"}}}}, {"uuid": "53cb1567-da04-45d8-9bf4-0dd5a812110d", "name": "padswitch(r:p1rdt5548-p1rdt5577)p1r_14632", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fead5749-3ba7-4ead-a604-e8adbd18f8c2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c1c8b424-4509-4fd2-93e2-4fd54f6cf49a"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "3baa725a-9b39-45f8-86af-c6afda2cdf9f"}}}}, {"uuid": "f1d7385c-f334-4abd-acbc-268a6e1aa5fb", "name": "padswitch(r:p1rdt5557-p1rdt5563)p1r_14619", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cca8918c-30e6-4619-a5e0-8c0d3451f9c4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c94489ed-4399-4dab-bab6-02b79f240f63"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "2f835dde-37f4-47dd-ab96-214dd85d3c9e", "name": "padswitch(r:p1rdt5557-p1rdt5563)p1r_14620", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fbc31b75-f942-4bae-8712-f1666d8b7f26"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ad24f98d-f022-4e62-b80b-426052810759"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "2419ddcd-627b-4faa-9878-65d4baf7d064"}}}}, {"uuid": "89b15386-98d4-4c15-bfd2-f82b5eea6b2a", "name": "padswitch(r:p1rdt5557-p1rdt5565)p1r_14621", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5e479d3-aae0-47b8-b707-bad1191df1e7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "efe7243f-340b-4114-be7c-f7494e78384f"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "ab2720f4-bdaa-4e93-a718-9d3398ce76a4"}}}}, {"uuid": "e2976123-591b-407f-8e3f-879e531049f6", "name": "padswitch(r:p1rdt5557-p1rdt5565)p1r_14622", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bfe92e2e-285d-4c58-8e0b-a462dd73fa41"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cca8918c-30e6-4619-a5e0-8c0d3451f9c4"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "bb21ddca-c238-4ca4-9574-9f21459c4f5a", "name": "padswitch(r:p1rdt5561-p1rdt5565)p1r_14623", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "756f6cd8-301b-4fac-b414-d72853616c6e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8bd0860f-2b3e-4c90-a571-cfc6aa649e5b"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "f58eeeef-b7c0-4252-b089-8de5183abc7c", "name": "padswitch(r:p1rdt5561-p1rdt5565)p1r_14624", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bebca5d7-2d4f-4655-a965-9faafd7a8125"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b5e479d3-aae0-47b8-b707-bad1191df1e7"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "74d1d12a-803b-48eb-8e5b-0df008dc80b1", "name": "padswitch(r:p1rdt5551-p1rdt5561)p1r_14625", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f7fed4f-197e-4a79-97e5-df595377736b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "27ab530f-a58e-4113-80f6-63f768910204"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "772c9103-cfcf-4ab9-ac69-f02423fe009f", "name": "padswitch(r:p1rdt5551-p1rdt5561)p1r_14626", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf97a458-469e-4609-bb33-97454e7c2b68"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "756f6cd8-301b-4fac-b414-d72853616c6e"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "278a53ba-f477-4f46-be13-b05dcff80778", "name": "padswitch(r:p1rdt5548-p1rdt5551)p1r_14629", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bf1b63d-fbce-42f8-9948-2e09bfa67409"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d447cf8-7b2b-45f1-8084-6fe4897e1853"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "c01372a2-4296-4877-a1f3-dd8c06d37f74"}}}}, {"uuid": "020e3a1d-353f-48a4-a297-a32861f78a5c", "name": "padswitch(r:p1rdt5548-p1rdt5551)p1r_14630", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5ec70f12-a676-48cd-b626-34f8d7f6a5bf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f7fed4f-197e-4a79-97e5-df595377736b"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "75397079-8541-4fed-9f2e-283746d35392", "name": "padswitch(r:p1rdt5548-p1rdt5566)p1r_14633", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fed9557-b170-4817-8bd8-efc3b9f7c982"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "10f43169-4b4b-4dbe-8f09-af72d427d6c7"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4900e609-ebb1-44db-852b-602449095f15"}}}}, {"uuid": "9fbe0ee9-ae7d-4233-af14-ea12e83dc720", "name": "padswitch(r:p1rdt5548-p1rdt5566)p1r_14634", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "23163dba-070c-435c-bb90-77be7ded002a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bf1b63d-fbce-42f8-9948-2e09bfa67409"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "d4fd35e4-7997-430a-854e-c1cdde29c7cc", "name": "padswitch(r:p1rdt5566-p1rdt5574)p1r_14635", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e9906676-e9b9-4d51-b1c2-a6b6fe187faa"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bf619f04-1fa5-4be7-8a76-669b79436d3e"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "f3caa620-fb40-4165-abf4-46f624ae5a85", "name": "padswitch(r:p1rdt5566-p1rdt5574)p1r_14636", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c264e6de-a898-421d-a2fe-ce6548aa477e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9fed9557-b170-4817-8bd8-efc3b9f7c982"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "99530725-fc4c-4216-8e67-a4469035c280"}}}}, {"uuid": "8e708baa-3ad1-4899-8c29-fc507efdc551", "name": "fuse(r:p1rdt31-p1rdt38)p1r_16627", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7c543753-fa26-41df-b7a6-3664395c0d45"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "668d32be-c07a-4387-86a5-e9754af11e9c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "5ef87d33-a0f9-4b56-9457-0d7cb679088c", "name": "fuse(r:p1rdt210-p1rdt44)p1r_16628", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d9ee2ff-e2bc-4d76-b173-5ba5cc48c9b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d1be5e34-ad5e-4c78-8067-8e0194c661a4"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "251fa307-5e1e-4ffa-a841-ff333862a949", "name": "fuse(r:p1rdt259-p1rdt44)p1r_16629", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3d9ee2ff-e2bc-4d76-b173-5ba5cc48c9b3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f0b5743e-c3fd-49c7-879e-9be7d00c480f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "105be1c0-9f28-4814-ab44-267fbb4f0af7", "name": "fuse(r:p1rdt58-p1rdt69)p1r_16631", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9396562e-4f87-4e04-b248-502b851fe19e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7238345a-1fc7-4f3f-bc8b-88cf7582c75c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "c452d159-ea97-4544-ab4a-93d0e7ce8631", "name": "fuse(r:p1rdt37-p1rdt80)p1r_16632", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b03f8e29-a5b2-4bed-b68c-219276674b6a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a2b529c9-4695-42f3-a0e3-69bbb34ff285"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "da4bb223-04fc-4e5d-b2db-f16866497bb6", "name": "fuse(r:p1rdt74-p1rdt85)p1r_16633", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6fc415bc-f457-4e9f-bbd4-783a71b67ad6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b82a9a2-b1d1-44eb-a451-946643ef613d"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "58221277-9ee4-4071-8967-a1d0bdcbbf92", "name": "fuse(r:p1rdt150-p1rdt71)p1r_16651", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "12451cbc-eb14-4814-b274-12eb2241c78a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "eab6b8c5-ee7a-4779-b5eb-5205dbe5253c"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "74603d74-9f0d-4842-b655-cfdee489dad0", "name": "fuse(r:p1rdt251-p1rdt254)p1r_16679", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b801037a-e1bb-4c5c-8d18-ed285c8c1d3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9c899bc-796a-4e92-88db-6aa11f8777cb"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "25c5e70e-dd57-4030-b431-72effcf942e6", "name": "fuse(r:p1rdt252-p1rdt385)p1r_16680", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "69b2ee46-ab5f-48c8-a26b-170ed2b57fcb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "22179eaa-fd19-4619-8b31-52bcb36ec683"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770"}}}}, {"uuid": "af70abad-e2d2-466e-ac06-19c43f7ce09a", "name": "fuse(r:p1rdt261-p1rdt277)p1r_16684", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "add5e39f-f02e-4a61-a156-d5721cec25d5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bbe3ac37-aca0-47fd-ac5d-be390cad10ab"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "5cb48d44-c6a0-4b2a-ae95-38168b6ed9e6", "name": "fuse(r:p1rdt279-p1rdt89)p1r_16685", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "153bb615-5ee5-4eec-bcf7-94ea0098aeb6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "232adbbb-2715-44be-8db5-ee062ebf4e46"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "ae0efabc-30d4-4b0b-87f1-14de9ef567fc", "name": "fuse(r:p1rdt335-p1rdt376)p1r_16692", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b07c4a6-39a7-4521-bce7-3f1ca0ff4a66"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0de112ae-d04a-4673-98af-0699e4890429"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "804bf703-8117-4553-b55c-90b0e0138f28", "name": "fuse(r:p1rdt415-p1rdt419)p1r_16706", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81cfd2a2-295c-4b73-abba-05ffee810523"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "19116f3c-29ae-4819-ba72-dd0f8afa5078"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "cc0d8f4f-cb74-41bf-915f-657a26c4dce0", "name": "fuse(r:p1rdt456-p1rdt465)p1r_16710", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a94f7afe-e8b0-4b24-8196-6b05e98c3830"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b092ee09-4c5e-46b5-8ec2-51f99254c220"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "9d67edf0-3af2-46a6-b5a7-af017e3a23be", "name": "fuse(r:p1rdt458-p1rdt468)p1r_16711", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a180b972-cf0e-4a2e-9bcf-a0ad90bb3d83"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "04fc215c-7f3e-45e1-a49c-727b0fcdae93"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770"}}}}, {"uuid": "e812226f-f357-4c18-96e8-9949554baf21", "name": "fuse(r:p1rdt468-p1rdt474)p1r_16712", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a180b972-cf0e-4a2e-9bcf-a0ad90bb3d83"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5814195b-dd60-4a1e-9af6-b9b84fa4c0c7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "9860b763-07dc-4e8d-8870-1afd3a7f37e2", "name": "fuse(r:p1rdt466-p1rdt478)p1r_16713", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2eba354c-f4bf-4c49-a8ad-998ab9489e5a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64ba6716-89f9-49a4-9793-ba80ae41bcd0"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "da8c1709-80de-4678-8309-269d2f230e38", "name": "fuse(r:p1rdt482-p1rdt485)p1r_16714", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "445f61a4-8045-4558-a3c1-bb44336737ec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e4064b6c-40b4-418b-95ab-4f9bb0363b14"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770"}}}}, {"uuid": "c04ff227-206a-442c-a266-475342372f3b", "name": "fuse(r:p1rdt483-p1rdt485)p1r_16715", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "445f61a4-8045-4558-a3c1-bb44336737ec"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d899b807-b194-4f65-bad5-a39e8bc61906"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "768cdac9-b64c-40b0-a33b-738ba6b7e482"}}}}, {"uuid": "2b29065b-ab29-4a29-992e-6fa020baefb0", "name": "fuse(r:p1rdt5548-p1rdt5577)p1r_17662", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6bf1b63d-fbce-42f8-9948-2e09bfa67409"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "25ee6008-ddbc-4e7b-8a57-ff38c16368a2"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "73f75b89-55b4-4a16-9fa1-8771daf3d5be"}}}}, {"uuid": "ac5b78b4-1db7-4049-8ac8-190123ae26d7", "name": "fuse(r:p1rdt5551-p1rdt5568)p1r_17664", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5f7fed4f-197e-4a79-97e5-df595377736b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "514ad102-b590-4ad8-a258-2b6fa8dcbeb1"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "861d64ae-aba6-4135-a3ca-f177438722a2"}}}}, {"uuid": "6de2926c-cdd7-4dbe-954c-e5e73d440add", "name": "fuse(r:p1rdt5560-p1rdt9055)p1r_17668", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "68117bef-16c5-40c9-9356-76ef5c056650"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "30adfcd5-405b-47ea-be54-55c5a47c835f"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "b77c5f87-769c-4ad7-b6b5-9fbe48d98a9e", "name": "fuse(r:p1rdt6488-p1rdt7300)p1r_17851", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63b2f1e6-5e15-4433-85ee-ff7bb7218b96"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "47f8ed28-4bff-47d9-8ffe-4509e9c5b7fc"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "3228c925-05c0-4c64-b9fc-c95e6716280b", "name": "fuse(r:p1rdt7757-p1rdt7795)p1r_18078", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "081feb5c-d5d5-405e-85d4-f1dd0916fc3d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0cd22d3e-1e2a-4a99-9967-b9df95837915"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "5bbe221f-b4a5-48b0-807d-e4b8038385f1", "name": "fuse(r:p1rdt8111-p1rdt8138)p1r_18142", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17b633c6-214d-4428-bded-df737f50ffb6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "9929e0d4-3e33-4f5f-b718-6a629cc52242"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "1f205dc8-03e2-4638-9e38-39bda752ee14", "name": "fuse(r:p1rdt5098-p1rdt8169)p1r_18150", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f6bdb2cf-9373-4d56-a5f9-cb8fa9c67e55"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cb3d775d-8d92-498b-989c-387278ec8e9e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "7a9f88b5-9266-4dc3-94d4-4b1fd3397487", "name": "fuse(r:p1rdt6266-p1rdt8174)p1r_18152", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b0f9433-e0a3-458a-8687-c9cf38d0bbb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d07105ef-1ba3-4775-aeb4-650b5ea8736e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "a2d33cd0-44ed-4544-b661-7bb0b19b8770"}}}}, {"uuid": "d30f8def-15f6-47be-ab3f-8814ccb37121", "name": "fuse(r:p1rdt8180-p1rdt8201)p1r_18154", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c93a476-4ad5-41cd-a07b-e2ccc9ef2c3b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "63928702-c44a-4e83-9cca-7ce77bdbd2b3"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "6b0a6718-181b-4c20-9dc3-45257942ad04", "name": "goab_disswitch(r:p1rdt335-p1rdt419)p1r_20734", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "81cfd2a2-295c-4b73-abba-05ffee810523"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d2efeaf5-2055-4718-a064-7c5e00b7d87d"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "2419ddcd-627b-4faa-9878-65d4baf7d064"}}}}, {"uuid": "a8dbe250-f335-4a33-8967-d9144ec88082", "name": "goab_disswitch(r:p1rdt276-p1rdt279)p1r_20887", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "186ffdfe-2346-4218-bd6b-b813ea6b3b62"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7140d97e-416e-47ec-9f86-46ad6f9abece"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "466a17b2-2a29-4496-8652-610b208f7f1b", "name": "disswitch(r:p1rdt181-p1rdt297)p1r_20911", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d32493ec-06be-48ef-959e-779c79c507a3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2fddf29e-6eef-4c60-ad8b-4580440973b3"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "7351fbec-02bf-4cbf-aea9-09a23aa2a9b8", "name": "goab_disswitch(r:p1rdt237-p1rdt276)p1r_20993", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8c8b8f8-7a41-4d16-b509-2d7c7af9509d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c3ca9bee-26b0-4ef4-8555-6494ffdd6a17"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "2a5a5f0e-3473-4d3f-ac60-0c576781cacc", "name": "disswitch(r:p1rdt16790-p1rdt487)p1r_21007", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dfb0d992-ab18-4f73-933e-a01ce73ef3b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d53ff9fd-2b16-4026-88fa-2c112d4949c5"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "e7ce538c-39a2-4585-8cd8-85cefb5001b7", "name": "disswitch(r:p1rdt16604-p1rdt257)p1r_21113", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3fb307f7-3690-4931-999a-4daab4d8c9e5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7ef71bd7-4c82-4296-a6ac-64516ffe96c5"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "2d897f3c-bcb4-45c3-8f45-79a7882361d3", "name": "disswitch(r:p1rdt270-p1rdt298)p1r_21212", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7a468f13-c61f-4c01-aa27-c75fb02030e0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2c76250-d7ea-4da4-8008-dac1a579e974"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "05155e19-68bb-4b06-a90e-2af3c0f63384", "name": "recloser_disswitch(r:p1rdt8174-p1rdt8180)p1r_21285", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6b0f9433-e0a3-458a-8687-c9cf38d0bbb3"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "498a07ee-e12b-459a-a01f-f663a4a8428a"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "b8590a64-3624-43d1-8279-40a7928d98a9"}}}}, {"uuid": "4d2272d5-4fc9-48e9-84db-9b8f3f9f327a", "name": "disswitch(r:p1rdt383-p1rdt7300)p1r_21354", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "05f14a3e-053e-4b65-b962-da7804b9e2c1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9240d01-bf5d-41ed-8c53-c1f04af1a236"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}, {"uuid": "c57b3c83-e7ed-4283-84e7-230a16052433", "name": "l(r:p1rdt383-p1rdt7300)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e5ac1506-77e9-4b90-ad3d-18be099063a9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16ace27f-f5fa-4fd1-840e-8cae55dbe1b2"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "40a26197-da2a-4e22-a50a-3922efd7762c"}}}}, {"uuid": "dfe3055b-071a-4b16-a1f5-8817c9563e7c", "name": "l(r:p1rdt383-p1rdt7300)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "16ace27f-f5fa-4fd1-840e-8cae55dbe1b2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d49257c8-f8eb-4024-9c02-461d18cdd3d5"}}}], "length": {"value": 2.9030580000000006, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "4bd7147d-d66a-4be7-afc9-1ac8815e7212", "name": "l(r:p1rdt181-p1rdt66)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "24681ab1-3904-4509-85e6-d9bb1dba4c8e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6b5c947-b0c5-4e20-bd74-bf847bdacd30"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "40a26197-da2a-4e22-a50a-3922efd7762c"}}}}, {"uuid": "239c598c-522f-4509-8755-3e56148c7ce9", "name": "l(r:p1rdt181-p1rdt66)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e6b5c947-b0c5-4e20-bd74-bf847bdacd30"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "99615f32-0614-4c23-a1e1-b3e8e5688cce"}}}], "length": {"value": 1.8166859999999998, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c0340108-7ee4-45aa-91e0-afcce5d859a4", "name": "l(r:p1rdt181-p1rdt297)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d87f56c0-0a3f-4a94-8f60-1ece461290d0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "71abd5f1-ca61-4754-a2ef-7b5d4e635f99"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "40a26197-da2a-4e22-a50a-3922efd7762c"}}}}, {"uuid": "ef009cf0-e83d-4133-b85e-647ec7c82b7f", "name": "l(r:p1rdt181-p1rdt297)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "71abd5f1-ca61-4754-a2ef-7b5d4e635f99"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "79d0fee6-369b-4f95-a2d2-cd05232652e3"}}}], "length": {"value": 4.570002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d448bbc0-7a67-4bb2-94aa-7d605ebab0df", "name": "l(r:p1rdt270-p1rdt298)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ac7c613f-190c-493e-8e89-3ef48e8efdb9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0fad7ee-b65c-460c-94ca-fe9546a5b140"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "40a26197-da2a-4e22-a50a-3922efd7762c"}}}}, {"uuid": "c9722f40-a6c0-4a05-a737-bd2ff278c33d", "name": "l(r:p1rdt270-p1rdt298)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["B"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b0fad7ee-b65c-460c-94ca-fe9546a5b140"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7eca59ac-01f1-40d7-a0ec-51f355285e01"}}}], "length": {"value": 2.6162099999999997, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "3e4e6114-3df1-4523-b480-028a3f01d2e4", "name": "l(r:p1rdt16604-p1rdt257)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "282d8a89-8b14-476b-9e55-b310d8b9396d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8064f1d-11b7-4913-8344-175c1388be3e"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "40a26197-da2a-4e22-a50a-3922efd7762c"}}}}, {"uuid": "642f1479-fef3-4ab0-869d-276f7aaeca18", "name": "l(r:p1rdt16604-p1rdt257)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b8064f1d-11b7-4913-8344-175c1388be3e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "98a946e8-3c8a-49ec-be8a-5610c7fc596c"}}}], "length": {"value": 2.362599, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "a7288c5c-c39d-4983-bd6a-e028ec000d5f", "name": "l(r:p1rdt7711-p1rhs7_1247)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1548dd91-bc3d-4a2c-903f-48e11159c558"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2131350-dc34-4d8d-8c9f-c29e25bc654c"}}}], "length": {"value": 2.34083, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "dfffd734-a5e2-42da-a25d-4360affa98b0", "name": "l(r:p1rdt7711lv-p1rlv16411)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64b60527-0853-4973-8d7a-78ba5e377799"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3ed6276c-a57b-40be-a1f1-34aaaba0ac28"}}}], "length": {"value": 0.0104732, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "4eb8fe85-248b-4062-b84b-bd291bf09b51", "name": "l(r:p1rdt7711lv-p1rlv20414)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "64b60527-0853-4973-8d7a-78ba5e377799"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e0a92e79-0ca2-4a10-9050-9e8d7442b019"}}}], "length": {"value": 0.0104732, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "9e9dcf4a-3b83-4e15-a8d0-6f5351cdc13c", "name": "l(r:p1rdt8473lv-p1rlv18169)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "439728c5-fee5-4dfa-9894-261ba6c40e95"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3c1eac45-623a-4f0a-874d-a4b56a8e2ea7"}}}], "length": {"value": 0.0202596, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "8285453f-abc7-420b-93ac-60cb9aaef09e", "name": "l(r:p1rdt8473lv-p1rlv18194)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "439728c5-fee5-4dfa-9894-261ba6c40e95"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "949f4cce-f321-4bf0-830b-489edc9964c7"}}}], "length": {"value": 0.0202596, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "d9d639df-5b76-47fe-9b75-d4e7ec515ae1", "name": "l(r:p1rdt6028lv-p1rlv12518)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35f6f747-811d-4fe2-a9c7-991248572c74"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "72f659b6-d302-4887-a2f6-1a477ad3324c"}}}], "length": {"value": 0.0196521, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "9475313a-299b-446b-91ed-94cdb2d345d5", "name": "l(r:p1rdt6028lv-p1rlv12528)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35f6f747-811d-4fe2-a9c7-991248572c74"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f9660b80-0fce-4be4-b541-743d5811133c"}}}], "length": {"value": 0.0563852, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "ffe84a3b-76b8-4dec-9c29-0084691588fe", "name": "l(r:p1rdt6028lv-p1rlv12534)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35f6f747-811d-4fe2-a9c7-991248572c74"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8796d817-aad6-4d22-b3d4-baf8a686c9df"}}}], "length": {"value": 0.00754144, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "4a309f30-e352-4599-9dee-ffca476a4e9e", "name": "l(r:p1rdt6028lv-p1rlv12536)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "35f6f747-811d-4fe2-a9c7-991248572c74"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e89452f3-ce44-46d3-a259-f66044e01c2c"}}}], "length": {"value": 0.0368264, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "7399e1c5-5e83-4fa9-a9b6-9d3a1a693f55", "name": "l(r:p1rdt9478lv-p1rlv20501)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddf38626-1223-429f-a903-98f1c975020b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cebe1b53-cca6-4bd4-a9f0-616ffb9750b3"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "f3e4b646-2702-4787-930b-a42a5c45d53f", "name": "l(r:p1rdt6232lv-p1rlv12985)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3e2630e1-a215-4740-9327-fa004e89863d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "df3aae83-f4b0-4db2-9301-dff1664ac23e"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "8e5baa4c-dd50-4330-b9cb-45f46ac26d1c", "name": "l(r:p1rdt6232-p1rdt9478)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c49b6e87-5834-4e7e-a64c-b4ec0f7d4995"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b59ad93a-cca2-4a77-8515-a645ddd2a320"}}}], "length": {"value": 0.08088850000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "d287939e-187e-44ce-adc8-c5deb1efe035", "name": "l(r:p1rdt6028-p1rdt9478)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e39cb1db-d6a6-4b6c-bc73-920e0c34c292"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f77960bf-f017-400c-b505-16e7c2e90fe7"}}}], "length": {"value": 0.29557, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "38175911-904e-413e-b9f3-ba12b0d54714", "name": "l(r:p1rdt6028-p1rdt8473)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3a83211-0829-4e2c-b618-3f1fcaba3e87"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e39cb1db-d6a6-4b6c-bc73-920e0c34c292"}}}], "length": {"value": 0.233087, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "24ba44ff-6a1e-424c-802a-5e685da39576", "name": "l(r:p1rdt7711-p1rdt8473)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2131350-dc34-4d8d-8c9f-c29e25bc654c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b3a83211-0829-4e2c-b618-3f1fcaba3e87"}}}], "length": {"value": 0.502313, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "c94a5bb4-b7c5-4f79-9cf8-1375d4c8b6cb", "name": "l(r:p1rdt8493lv-p1rlv18201)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c330731a-fd2c-40c7-8fce-94f7e17cf6d9"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ead37cb8-af1e-4a46-9466-6ff298b7f8b7"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "53af44df-3038-4acb-b26d-2e276e4f2b7b"}}}}, {"uuid": "248b171b-5e13-4070-b36a-12d088475c3c", "name": "l(r:p1rdt7711-p1rdt8493)", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e2131350-dc34-4d8d-8c9f-c29e25bc654c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cfb41891-7063-44b8-9286-1fe763e49924"}}}], "length": {"value": 0.719466, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "5cd18c4b-7e66-4567-99aa-adbf0e339973", "name": "l(r:p1rdt6028-p1rdt9478)_disconnect", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "is_closed": [true, true, true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f77960bf-f017-400c-b505-16e7c2e90fe7"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "409a29cf-ddd5-4031-92ca-db6cd2410704"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "4ef14ced-0dd0-45e9-8617-21a57b590523"}}}}, {"uuid": "937849ae-e1ac-40fe-b786-984a89a281f3", "name": "l(r:p1rdt6028-p1rdt9478)_cont", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "409a29cf-ddd5-4031-92ca-db6cd2410704"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c49b6e87-5834-4e7e-a64c-b4ec0f7d4995"}}}], "length": {"value": 2.66913, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "87fc45c2-660b-4f99-b658-eb377ae27502", "name": "l(r:p1rdt93lv-p1rlv183)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0921e58d-1ada-4556-8b01-8f22d3bf4ee2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3df778b4-e60b-4e17-b24b-67742d090f42"}}}], "length": {"value": 0.062918, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0c7ce66f-32b1-4f29-8c1b-ff8cb7cbe189", "name": "l(r:p1rdt93lv-p1rlv204)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0921e58d-1ada-4556-8b01-8f22d3bf4ee2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d663fcdc-6c67-4bc9-99ed-12439f75804f"}}}], "length": {"value": 0.0275441, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c67015ab-e194-4fac-82b0-87878c41d658", "name": "l(r:p1rdm198-p1rlv206)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2be21180-bfa8-4cd1-a3c5-68602896d657"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "90aa0d14-285a-4468-bbde-8d76f65b1780"}}}], "length": {"value": 0.047457, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "04bb6407-6835-4d3c-8629-76af3bf1c2ae", "name": "l(r:p1rdm198-p1rdt93lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0921e58d-1ada-4556-8b01-8f22d3bf4ee2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2be21180-bfa8-4cd1-a3c5-68602896d657"}}}], "length": {"value": 0.0116535, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "8364cd7f-2820-4bcf-bb37-67dadafb4bb2", "name": "l(r:p1rdm199-p1rlv207)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a70fd02-3816-451f-a509-2ad767068eb4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6627102c-4524-4e69-bb4d-5b93226df412"}}}], "length": {"value": 0.0665106, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "a2920457-6a3e-4fb5-95d3-b5dfbe0a7490", "name": "l(r:p1rdm196-p1rlv184)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6065e92f-dd89-4aeb-94af-173d81a49df1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "42ca8327-5dcc-415a-820c-ef6ec038b3d8"}}}], "length": {"value": 0.0719696, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "382af86a-c688-4778-b6b8-2005858ec39b", "name": "l(r:p1rdm196-p1rdm199)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a70fd02-3816-451f-a509-2ad767068eb4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6065e92f-dd89-4aeb-94af-173d81a49df1"}}}], "length": {"value": 0.0157359, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "796dcb0c-914a-4476-8a88-6a5c6023faca", "name": "l(r:p1rdm199-p1rdt93lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0921e58d-1ada-4556-8b01-8f22d3bf4ee2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6a70fd02-3816-451f-a509-2ad767068eb4"}}}], "length": {"value": 0.00889089, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "2d347746-0969-4a8a-b986-c40ef4f4c015"}}}}, {"uuid": "3a950c68-44a5-458a-ae67-40de974d8047", "name": "l(r:p1rdt99lv-p1rlv190)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef6be92d-5d1b-40e2-a2c2-9d0c1f0bf596"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "33b6400e-c84e-43cf-b254-99f946e5a308"}}}], "length": {"value": 0.040055, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "4ab7dd7f-8f59-4338-807a-6a59fdb9d2c6", "name": "l(r:p1rdt99lv-p1rlv202)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ef6be92d-5d1b-40e2-a2c2-9d0c1f0bf596"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "de2366e4-30da-429a-82b9-c0ef27eeab47"}}}], "length": {"value": 0.040055, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "c79aa124-41f0-475e-b27b-c7974a25b335", "name": "l(r:p1rdt101lv-p1rlv193)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "1277a701-9fbd-4853-a809-962475e016c4"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "84223c1b-69e4-4ebc-8274-8706bb412780"}}}], "length": {"value": 0.060663, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "5ef15021-e9f7-4934-ad47-fa982ef83d7f", "name": "l(r:p1rdt108lv-p1rlv212)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3aa8d6f2-8d84-42d6-8e7b-89e3b1efa03c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a982feac-5730-4fe0-a1b8-25c06b36e3b0"}}}], "length": {"value": 0.0158014, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "9ba90c4e-cda5-4a96-8214-9766f675c80a", "name": "l(r:p1rdt6121lv-p1rlv12687)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "448cc5e0-391f-4a6b-8199-25cef4593edf"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "163c3824-6847-4b94-9e81-08f15f4667a1"}}}], "length": {"value": 0.0852199, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "b466ad0c-36a2-4215-b99e-1e2e9147cca4", "name": "l(r:p1rdt6123lv-p1rlv12713)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5e81ba94-5857-42e4-aeee-58542cef0fb6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ff16aad0-98c1-4563-a844-e0ce909c1a79"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "6db4a71c-d59e-49fb-b9ee-3aebd949e6ab", "name": "l(r:p1rdt8017lv-p1rlv17006)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8428de0e-4b06-4f19-bffb-5fed32f96f67"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b53edd15-5a3e-4b7a-97c4-046582bb4801"}}}], "length": {"value": 0.0396626, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "6f7024dc-43c4-4070-b610-d88c786d2e4b", "name": "l(r:p1rdt8043lv-p1rlv17103)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a367e687-b29a-44b4-a943-7b94762e549e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8ff9eb4c-2523-48e0-8490-619d26b9cca4"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "171b2896-2adb-4810-b5fb-e37fe81ec7b0"}}}}, {"uuid": "b797d3a2-ee2f-4f54-b06e-9fa0e6dbb21e", "name": "l(r:p1rdt8065lv-p1rlv17155)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8bb025c5-31eb-4771-b433-e1dcad03b3ed"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a3c6c52e-cf93-467a-a303-94b96b33a3da"}}}], "length": {"value": 0.00641649, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "6f467e58-32b6-4e07-9a32-2fcae57445d9", "name": "l(r:p1rdm17752-p1rlv17164)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62e77e46-bf33-474f-907b-81d36aae8975"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "041caa30-2985-44ca-8013-e11a9bda7dff"}}}], "length": {"value": 0.0585553, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "aa9f431f-8d45-4d2f-b3ef-6ed973e7fdfe", "name": "l(r:p1rdm17752-p1rdt8068lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd01eed6-0e70-42e7-ac29-4bfd2f70366a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "62e77e46-bf33-474f-907b-81d36aae8975"}}}], "length": {"value": 0.00975828, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "46cadd28-41d2-4b33-b229-53938b6526d2", "name": "l(r:p1rdm17753-p1rlv17199)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "46b5c5bc-6738-4520-b98c-32bd43f4c91c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5768eaca-abe3-4347-af78-02b50ec6f2a9"}}}], "length": {"value": 0.07246250000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "815be72a-4590-47bf-b23a-93bee76e3ffc", "name": "l(r:p1rdm17753-p1rdt8068lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dd01eed6-0e70-42e7-ac29-4bfd2f70366a"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "46b5c5bc-6738-4520-b98c-32bd43f4c91c"}}}], "length": {"value": 0.00869985, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "07d3ecbb-c8d8-4498-b7de-9dede233fa9a", "name": "l(r:p1rdt8070lv-p1rlv17167)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0bcd460-ccf2-42ee-83c6-bada397ab4d6"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b4e44ab-e644-4e48-b1b2-82dc15d38d17"}}}], "length": {"value": 0.0455049, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "e1c383ad-81e0-4ef4-8d77-433f8c2369fc", "name": "l(r:p1rdt8190lv-p1rlv17376)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f21f4e99-8877-4bb0-9956-9240bc6db3d1"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c9970ae-e914-407d-8222-12c08638a854"}}}], "length": {"value": 0.0538062, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "5c4315d9-3bd5-4e8d-8f59-4e452cc39791", "name": "l(r:p1rdt8204lv-p1rlv17402)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d12bf6fb-8dac-4729-bcda-1ee61c63f6e8"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dc7fa312-1baf-4f23-925f-a281071183a6"}}}], "length": {"value": 0.020109400000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "930a8c5d-1c84-449e-aeb0-b249e1fc8fbe", "name": "l(r:p1rdt8208lv-p1rlv17413)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ecf11723-eb6d-423c-ac0c-85fa2d1ba846"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f147f7e5-33e8-430b-9822-715e772debb3"}}}], "length": {"value": 0.058289, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "49a21a95-e38f-4a69-be2a-b889705a3a47", "name": "l(r:p1rdt8578lv-p1rlv18362)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1a593e3-4735-47d2-b893-dd2d07c3c47c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "5a28b095-45f5-43ec-983b-c1de596d4cb5"}}}], "length": {"value": 0.0205693, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "dc98da20-4587-480f-8cb1-3a411d9e0658", "name": "l(r:p1rdt8578lv-p1rlv18364)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1a593e3-4735-47d2-b893-dd2d07c3c47c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8d1c3d0a-9def-4516-8429-386f1d70f506"}}}], "length": {"value": 0.0370574, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "f8487d44-54da-4eec-870f-b9de934b0640", "name": "l(r:p1rdt8578lv-p1rlv18367)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "f1a593e3-4735-47d2-b893-dd2d07c3c47c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "408c825d-17ac-4aea-9fc7-fff420657fc7"}}}], "length": {"value": 0.018828, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "cce59d54-5697-4708-a924-410992705356", "name": "l(r:p1rdt8583lv-p1rlv18370)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "134bac3d-5b7e-48d7-950e-01e5b7d43852"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "905e171c-13d7-4f8d-b88a-7501b2327d81"}}}], "length": {"value": 0.0934621, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "72285fbb-7891-4916-bd04-d67ce9189e58", "name": "l(r:p1rdt8584lv-p1rlv18371)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a8ba1042-fcfd-47a8-aa0f-8b13618d3212"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "58792e8c-3ad9-45bb-ac47-01983cca2a2b"}}}], "length": {"value": 0.0568796, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d48c7473-cf0b-49c9-bea8-a9deb2957934"}}}}, {"uuid": "0ed44728-cace-4d39-8182-28659b1113a8", "name": "l(r:p1rdt10491lv-p1rlv22745)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8f14e6e-ee96-4ae9-86ba-4a07cf103b65"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a86348e4-7573-4903-b223-90155579923e"}}}], "length": {"value": 0.00860717, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "69f39247-71ec-4488-a1b5-9cd9caff8cb6", "name": "l(r:p1rdm23269-p1rlv22758)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee8b6bab-9edd-4250-b57b-3a76b432fb54"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "db05b7f0-d2a8-4876-876e-ef0e9b469580"}}}], "length": {"value": 0.0077383, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "545f2993-60ea-4122-8ac8-124799e17c31", "name": "l(r:p1rdm23269-p1rdt10491lv)", "substation": null, "feeder": null, "in_service": true, "phases": ["S2", "S1", "N"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "c8f14e6e-ee96-4ae9-86ba-4a07cf103b65"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ee8b6bab-9edd-4250-b57b-3a76b432fb54"}}}], "length": {"value": 0.017970700000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "d1ff9b87-e3ff-4119-a169-fc0e548cb580"}}}}, {"uuid": "a19ed19d-f5f9-42c8-b5d1-520605196747", "name": "l(r:p1rdt8065-p1rdt8070)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473520c7-0098-4bc2-a46f-07efd6c3759c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "862f3566-9443-4b82-8f05-c994581e131a"}}}], "length": {"value": 0.11506000000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f82ea167-4bb5-4acb-8736-ba3098b01929", "name": "l(r:p1rdt8068-p1rdt8070)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473520c7-0098-4bc2-a46f-07efd6c3759c"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "7f5fbb8b-0c32-4aa7-acaf-7ea2b5e56505"}}}], "length": {"value": 0.0454225, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "2cfe2726-ca82-4184-af38-1db485d3622d", "name": "l(r:p1rdt8043-p1rdt8070)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "691c1909-3b71-4e07-abf0-95aaabfa23bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbafbe81-1649-4bae-b9af-c4b1757392f0"}}}], "length": {"value": 1.20903, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "c939ca25-23bc-45e6-afb1-34c98b300b8d", "name": "l(r:p1rdt8043-p1rdt8070)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "cbafbe81-1649-4bae-b9af-c4b1757392f0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "473520c7-0098-4bc2-a46f-07efd6c3759c"}}}], "length": {"value": 0.714168, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1a6283f9-eca9-4da3-9aec-868e430d702b", "name": "l(r:p1rdt10491-p1rdt8043)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "691c1909-3b71-4e07-abf0-95aaabfa23bb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ca19324f-0855-4633-be68-b16c872e196d"}}}], "length": {"value": 0.143178, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "f42fe8fc-80ec-4c50-a106-91fa534f3edc", "name": "l(r:p1rdt10491-p1rdt8043)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ca19324f-0855-4633-be68-b16c872e196d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "4737e613-8cf5-45d7-a3f5-71af051ece4c"}}}], "length": {"value": 1.81692, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d5dee6d5-a427-4319-b9b9-44bc16841f5f", "name": "l(r:p1rdt8017-p1rdt8043)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6378abd-969e-4ec8-93eb-2cc39cdb18eb"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "feda8d99-6fae-4c6e-bf52-f87894687da5"}}}], "length": {"value": 0.18707900000000002, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "ccb7a0ac-a308-4217-afd4-043b2b325c6b", "name": "l(r:p1rdt8017-p1rdt8043)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "feda8d99-6fae-4c6e-bf52-f87894687da5"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "691c1909-3b71-4e07-abf0-95aaabfa23bb"}}}], "length": {"value": 0.534353, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "db26ea21-d0ad-492d-88d3-62e4b8b52675", "name": "l(r:p1rdt101-p1rdt8017)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a09cdbca-4e7b-4d9a-b479-515074964171"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1aeba4b-536e-4067-a7a5-627470ae0711"}}}], "length": {"value": 0.331129, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "b5b98590-9dc7-4cd0-a4d2-066a47550a6e", "name": "l(r:p1rdt101-p1rdt8017)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b1aeba4b-536e-4067-a7a5-627470ae0711"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c1a4365-a594-48be-b138-aa6935c34481"}}}], "length": {"value": 2.00417, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e7f6e4db-47b4-40d6-b0c7-8836d796842d", "name": "l(r:p1rdt101-p1rdt8017)_s2", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8c1a4365-a594-48be-b138-aa6935c34481"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "b6378abd-969e-4ec8-93eb-2cc39cdb18eb"}}}], "length": {"value": 0.0990287, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "358ea440-8af5-49f3-a7e5-bf3ece06fe47", "name": "l(r:p1rdt101-p1rdt108)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e61ce952-a643-45aa-a466-8aa15ecceb48"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d8e5d83-cd9c-4527-9eef-6219c98dfe93"}}}], "length": {"value": 0.0862881, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e86bf583-73fe-41bb-bdae-274719a15774", "name": "l(r:p1rdt108-p1rdt93)", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4f100ee-0152-4e27-bf0e-2c7dea1537ad"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e61ce952-a643-45aa-a466-8aa15ecceb48"}}}], "length": {"value": 0.0403624, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "73cf1758-bfb1-404d-80ef-ae8deceb880c", "name": "l(r:p1rdt8204-p1rdt8208)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e2b4d77-2388-4897-86fe-06409fa9d222"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "fa2342e6-2d40-424a-830c-a84af4632b6e"}}}], "length": {"value": 0.29712, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "bc1ca79c-0481-4721-87d4-46e512a8cdcd", "name": "l(r:p1rdt8190-p1rdt8208)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a761aef-a766-40e2-b8d7-e5a918cece18"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "8e2b4d77-2388-4897-86fe-06409fa9d222"}}}], "length": {"value": 0.056324900000000004, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "e3ede097-3f6e-463a-8da9-8632b7c482b3", "name": "l(r:p1rdt8190-p1rdt99)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b860d5c-43e4-429e-b945-378020e3f926"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6be75535-8c32-47ea-bad5-986daaed0921"}}}], "length": {"value": 1.66165, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "700118f2-7a55-4195-9574-c5978603f45e", "name": "l(r:p1rdt8190-p1rdt99)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "6be75535-8c32-47ea-bad5-986daaed0921"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "0a761aef-a766-40e2-b8d7-e5a918cece18"}}}], "length": {"value": 0.18014, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "1b462af5-d08e-4ef0-a01e-73536834674c", "name": "l(r:p1rdt6121-p1rdt6123)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddf8f344-dcca-418d-850e-745f18d29660"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "17f807ba-6ad6-4fd9-9dd0-2c0bacea5b24"}}}], "length": {"value": 0.192685, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "d1b3aa3f-5f80-4d51-a2cd-0171c797aabb", "name": "l(r:p1rdt8583-p1rdt8584)", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0747505-3381-4df0-a86e-3859acac8496"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2b601580-3091-4d8c-9718-1367c7ed385f"}}}], "length": {"value": 0.11744700000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "a5b1f949-2886-49c7-9cd9-c3dfc4ede137"}}}}, {"uuid": "5a01c8c2-afff-4ba5-957f-a2692170814e", "name": "l(r:p1rdt93-p1rdt99)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "092a9d51-a39c-4c05-905e-93fb1ae96ba2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3d15ce6-878d-4dd5-bb33-5a0f6c11dded"}}}], "length": {"value": 0.141059, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "9a0a937c-8779-4945-b7a2-5c75476497cb", "name": "l(r:p1rdt93-p1rdt99)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "e3d15ce6-878d-4dd5-bb33-5a0f6c11dded"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "900d49ce-4834-4f99-8d74-a5e9d2f63ea0"}}}], "length": {"value": 0.0271696, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "bcaefac9-1c3b-4558-a4c8-277deff0ddcc", "name": "l(r:p1rdt6121-p1rdt99)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2390c014-d418-4d63-8438-529a036487db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49c9e6df-3490-4df1-88a0-8a83ca6cdd1e"}}}], "length": {"value": 0.978472, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "0aff09d1-b70c-477f-bd3b-0d2d1a8a6a03", "name": "l(r:p1rdt6121-p1rdt99)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "49c9e6df-3490-4df1-88a0-8a83ca6cdd1e"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "092a9d51-a39c-4c05-905e-93fb1ae96ba2"}}}], "length": {"value": 0.2822120000000001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "ec452fcc-6021-44bc-9ae1-4cb5035bb351", "name": "l(r:p1rdt6121-p1rdt8578)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb866499-9e9c-4394-bd76-d4320ba4934b"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "af229e5c-a70f-4354-bddc-4a2698802741"}}}], "length": {"value": 0.28336300000000003, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "439d6b78-6099-4abb-8944-85f4bdab8a16", "name": "l(r:p1rdt6121-p1rdt8578)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "af229e5c-a70f-4354-bddc-4a2698802741"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2390c014-d418-4d63-8438-529a036487db"}}}], "length": {"value": 3.58548, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "1950c059-99fb-4401-9f5c-76a93b596633", "name": "l(r:p1rdt8578-p1rdt8583)_s0", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dbb79e10-21ba-4f04-b8a3-0cf711d26d40"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "975237e9-bd83-4a30-83ab-221eb7f85c65"}}}], "length": {"value": 0.101019, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "562e52da-0402-4236-9daa-19322b4c4c58", "name": "l(r:p1rdt8578-p1rdt8583)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "975237e9-bd83-4a30-83ab-221eb7f85c65"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "bb866499-9e9c-4394-bd76-d4320ba4934b"}}}], "length": {"value": 0.293916, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "2e7af12b-e8d8-4dd6-b6a9-cd3b777924ce", "name": "l(r:p1rdt8583-p1rhs7_1247)_s1", "substation": null, "feeder": null, "in_service": true, "phases": ["A", "B", "C"], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_branch", "type": "MatrixImpedanceBranch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ec7726f8-0afb-4c35-8a1b-0691a8fb400d"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dbb79e10-21ba-4f04-b8a3-0cf711d26d40"}}}], "length": {"value": 1.53928, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_branch_equipment", "type": "MatrixImpedanceBranchEquipment", "serialized_type": "composed_component", "uuid": "6148f90f-6cfa-4038-a641-2905e51ba219"}}}}, {"uuid": "7393d5be-c8ab-4241-b345-50487d39c030", "name": "fuse(r:p1rdt108-p1rdt93)p1r_16636", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "900d49ce-4834-4f99-8d74-a5e9d2f63ea0"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a4f100ee-0152-4e27-bf0e-2c7dea1537ad"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "3b608405-4c97-4531-bc3d-fd9d98d5eef0", "name": "fuse(r:p1rdt8190-p1rdt99)p1r_16637", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "092a9d51-a39c-4c05-905e-93fb1ae96ba2"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "3b860d5c-43e4-429e-b945-378020e3f926"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "872c97b3-853e-44ec-9dc5-76b3b0c97047", "name": "fuse(r:p1rdt6121-p1rdt6123)p1r_17782", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2390c014-d418-4d63-8438-529a036487db"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "ddf8f344-dcca-418d-850e-745f18d29660"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "eebb5679-e562-4c44-912d-f2a3cf81f9a7", "name": "fuse(r:p1rdt8583-p1rdt8584)p1r_18243", "substation": null, "feeder": null, "in_service": true, "phases": ["C"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_fuse", "type": "MatrixImpedanceFuse", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "dbb79e10-21ba-4f04-b8a3-0cf711d26d40"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "d0747505-3381-4df0-a86e-3859acac8496"}}}], "length": {"value": 0.001, "units": "kilometer", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_fuse_equipment", "type": "MatrixImpedanceFuseEquipment", "serialized_type": "composed_component", "uuid": "d467095a-575e-4fb7-991f-4e2cdf643318"}}}}, {"uuid": "96f5f10a-4b99-43c0-ace7-9392756edbb1", "name": "disswitch(r:p1rdt101-p1rdt8017)p1r_21072", "substation": null, "feeder": null, "in_service": true, "phases": ["A"], "is_closed": [true], "__metadata__": {"fields": {"module": "gdm.distribution.components.matrix_impedance_switch", "type": "MatrixImpedanceSwitch", "serialized_type": "base"}}, "buses": [{"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "2d8e5d83-cd9c-4527-9eef-6219c98dfe93"}}}, {"__metadata__": {"fields": {"module": "gdm.distribution.components.distribution_bus", "type": "DistributionBus", "serialized_type": "composed_component", "uuid": "a09cdbca-4e7b-4d9a-b479-515074964171"}}}], "length": {"value": 0.001, "units": "meter", "__metadata__": {"fields": {"module": "gdm.quantities", "type": "Distance", "serialized_type": "quantity"}}}, "equipment": {"__metadata__": {"fields": {"module": "gdm.distribution.equipment.matrix_impedance_switch_equipment", "type": "MatrixImpedanceSwitchEquipment", "serialized_type": "composed_component", "uuid": "14ee131a-95b9-49c5-b11d-450705732a22"}}}}], "time_series": {"directory": "p1rhs7_1247_time_series"}} \ No newline at end of file diff --git a/tests/test_graph.py b/tests/test_graph.py index 0dbf2d2..ac104e9 100644 --- a/tests/test_graph.py +++ b/tests/test_graph.py @@ -6,7 +6,7 @@ DistributionLoad, ) from infrasys import Location -from gdm.quantities import PositiveDistance +from gdm.quantities import Distance from shift import DistributionGraph, NodeModel, EdgeModel from shift.exceptions import ( @@ -41,7 +41,7 @@ def distribution_graph(): node_1, node_3, edge_data=EdgeModel( - name="line-2", edge_type=DistributionBranchBase, length=PositiveDistance(1, "m") + name="line-2", edge_type=DistributionBranchBase, length=Distance(1, "m") ), ) @@ -70,9 +70,7 @@ def test_edge_addition(): node_1 = NodeModel(name="node_1", location=Location(x=1, y=1)) node_2 = NodeModel(name="node_2", location=Location(x=1, y=2)) graph.add_nodes([node_1, node_2]) - edge_data = EdgeModel( - name="line-1", edge_type=DistributionBranchBase, length=PositiveDistance(1, "m") - ) + edge_data = EdgeModel(name="line-1", edge_type=DistributionBranchBase, length=Distance(1, "m")) graph.add_edge( node_1.name, node_2.name, @@ -115,7 +113,7 @@ def test_adding_edge_that_already_exists(distribution_graph): "node_1", "node_3", edge_data=EdgeModel( - name="line-1", edge_type=DistributionBranchBase, length=PositiveDistance(1, "m") + name="line-1", edge_type=DistributionBranchBase, length=Distance(1, "m") ), )